  1. Efficient Energy Consumption Scheduling: Towards Effective Load Leveling

    Directory of Open Access Journals (Sweden)

    Yuan Hong

    2017-01-01

    Full Text Available Different agents in the smart grid infrastructure (e.g., households, buildings, communities consume energy with their own appliances, which may have adjustable usage schedules over a day, a month, a season or even a year. One of the major objectives of the smart grid is to flatten the demand load of numerous agents (viz. consumers, such that the peak load can be avoided and power supply can feed the demand load at anytime on the grid. To this end, we propose two Energy Consumption Scheduling (ECS problems for the appliances held by different agents at the demand side to effectively facilitate load leveling. Specifically, we mathematically model the ECS problems as Mixed-Integer Programming (MIP problems using the data collected from different agents (e.g., their appliances’ energy consumption in every time slot and the total number of required in-use time slots, specific preferences of the in-use time slots for their appliances. Furthermore, we propose a novel algorithm to efficiently and effectively solve the ECS problems with large-scale inputs (which are NP-hard. The experimental results demonstrate that our approach is significantly more efficient than standard benchmarks, such as CPLEX, while guaranteeing near-optimal outputs.

  2. Superconducting magnetic energy storage for electric utility load leveling: A study of cost vs. stored energy

    International Nuclear Information System (INIS)

    Luongo, C.A.; Loyd, R.J.

    1987-01-01

    Superconducting Magnetic Energy Storage (SMES) is a promising technology for electric utility load leveling. This paper presents the results of a study to establish the capital cost of SMES as a function of stored energy. Energy-related coil cost and total installed plant cost are given for construction in nominal soil and in competent rock. Economic comparisons are made between SMES and other storage technologies and peaking gas turbines. SMES is projected to be competitive at stored energies as low as 1000 MWh

  3. Survey of energy load leveling system in Europe; Energy fuka heijunka taisaku ni kansuru Europe chosa

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Y. [Setsunan University, Osaka (Japan). Faculty of Engineering

    1998-05-05

    This paper describes the survey of energy load leveling systems in Europe. In Denmark, especially regional heating is remarkably diffused, and they have 350 plants. With extending the service areas, the energy load leveling has been promoted. For the cogeneration plants of SK Power, the largest electric power company, they have hot water heat storage tanks for regional heat supply with a total capacity 2,200 MWh. The regional heating system in Goeteborg City of Sweden supplies 80% of the total heat demand of the city. Unused energy sources derived from petroleum refining, sewage treatment, and garbage burning are utilized. In Uppsala, they have seasonal heat storage systems using solar heat. The Vienna Regional Heat Supply Corporation supplies heat equivalent to 5,000 GWh a year. Cogeneration plants and garbage burning plants are used as heat sources, and 25% of the total heating in the city is supplied. In Austria, they have an electric power demand with a peak in winter, and they have a pumped-storage power station in Kaprun for the annual load leveling using dump power in summer. This paper also introduces a compressed air storage gas turbine plant at Huntorf of Germany, and a large-scale underground natural gas storage of Gaz de France. 6 figs.

  4. Community Energy: Analysis of Hydrogen Distributed Energy Systems with Photovoltaics for Load Leveling and Vehicle Refueling

    Energy Technology Data Exchange (ETDEWEB)

    Steward, D.; Zuboy, J.

    2014-10-01

    Energy storage could complement PV electricity generation at the community level. Because PV generation is intermittent, strategies must be implemented to integrate it into the electricity system. Hydrogen and fuel cell technologies offer possible PV integration strategies, including the community-level approaches analyzed in this report: (1) using hydrogen production, storage, and reconversion to electricity to level PV generation and grid loads (reconversion scenario); (2) using hydrogen production and storage to capture peak PV generation and refuel hydrogen fuel cell electric vehicles (FCEVs) (hydrogen fueling scenario); and (3) a comparison scenario using a battery system to store electricity for EV nighttime charging (electric charging scenario).

  5. 1-GWh diurnal load-leveling superconducting magnetic energy storage system reference design. Appendix A: energy storage coil and superconductor

    International Nuclear Information System (INIS)

    Schermer, R.I.

    1979-09-01

    The technical aspects of a 1-GWh Superconducting Magnetic Energy Storage (SMES) coil for use as a diurnal load-leveling device in an electric utility system are presented. The superconductor for the coil is analyzed, and costs for the entire coil are developed

  6. Thermodynamic analysis of load-leveling hyper energy converting and utilization system

    International Nuclear Information System (INIS)

    Kiani, Behdad; Akisawa, Atsushi; Kashiwagi, Takao

    2008-01-01

    Load-leveling hyper energy converting and utilization system (LHECUS) is a hybrid cycle which utilizes ammonia-water mixture as the working fluid in a combined power generation and refrigeration cycle. The power generation cycle functions as a Kalina cycle and an absorption refrigeration cycle is combined with it as a bottoming cycle. LHECUS is designed to utilize the waste heat from industry to produce cooling and power simultaneously. The refrigeration effect can be either transported to end-use sectors by means of a solution transportation absorption chiller (STA) as solution concentration difference or stored for demand load leveling. This paper shows a simulation of the LHECUS cycle. A computer model was written to balance the cycle and key parameters for optimizing the cycle were identified

  7. 1-GWh diurnal load-leveling superconducting magnetic energy storage system reference design

    International Nuclear Information System (INIS)

    Hassenzahl, W.V.; Rogers, J.D.

    1979-01-01

    A point reference design has been completed for a 1-GWh Superconducting Magnetic Energy Storage system. The system is for electric utility dirunal load leveling; however, such a device will function to meet much faster power demands including dynamic stabilization. The study has explored several concepts of design not previously considered in the same detail as treated here. Because the study is for a point design, optimization in all respects is not complete. The study examines aspects of the coil design; superconductor supported off of the dewar shell; the dewar shell, its configuration and stresses; the underground excavation and related construction for holding the superconducting coil and its dewar; the helium refrigeration system; the electrical converter system; the vacuum system; the guard coil; and the costs. The report is a condensation of the more comprehensive study which is in the process of being printed

  8. Energy storage for load leveling; Fuka heijunka ni kakasenai denryoku chozo

    Energy Technology Data Exchange (ETDEWEB)

    Morimoto, S. [Tokyo Electric Power Co. Inc., Tokyo (Japan)

    1996-09-20

    This paper introduces features and state of development of electric power storage technologies. Pumped storage power generation is a technology to store electric power by utilizing energy of position. However, because the plant locations are limited to mountainous areas far away from power demand areas, development of power storage technologies is being progressed from a new viewpoint of installing plants in the vicinity of demand areas. Superconduction power storage continues flowing current into a superconductor coil to store the power as electromagnetic energy, which is drawn out as electric power on request. Research and development is in progress in Japan on superconductor coils, permanent current switches, and control and protection systems. A flywheel system stores energy by rotating a disk at high speeds. Element technologies are being developed on long-period storage technologies such as superconductor magnetic bearings and high-speed rotating flywheels. For new load leveling batteries, development efforts are being given on sodium-sulfur batteries, zinc-bromine batteries, redox flow batteries, and lithium batteries. 3 refs., 1 fig., 2 tabs.

  9. 1-GWh diurnal load-leveling Superconducting Magnetic Energy Storage system reference design

    International Nuclear Information System (INIS)

    Rogers, J.D.; Hassenzahl, W.V.; Schermer, R.I.

    1979-09-01

    A point reference design has been completed for a 1-GWh Superconducting Magnetic Energy Storage system. The system is for electric utility diurnal load-leveling but can also function to meet much faster power demands including dynamic stabilization. This study explores several concepts of design not previously considered in the same detail as treated here. Because the study is for a point design, optimization in all respects is not complete. This report examines aspects of the coil, the superconductor supported off of the dewar shell, the dewar shell, and its configuration and stresses, the underground excavation and construction for holding the superconducting coil and its dewar, the helium refrigeration system, the electrical converter system, the vacuum system, the guard coil, and the costs. This report is divided into two major portions. The first is a general treatment of the work and the second is seven detailed technical appendices issued as separate reports. The information presented on the aluminum stabilizer for the conductor, on the excavation, and on the converter is based upon industrial studies contracted for this work

  10. Integration of supercapacitive storage in renewable energy system to compare the response of two level and five level inverter with RL type load

    Science.gov (United States)

    Jana, Suman; Biswas, Pabitra Kumar; Das, Upama

    2018-04-01

    The analytical and simulation-based study in this presented paper shows a comparative report between two level inverter and five-level inverter with the integration of Supercapacitive storage in Renewable Energy system. Sometime dependent numerical models are used to measure the voltage and current response of two level and five level inverter in MATLAB Simulink based environment. In this study supercapacitive sources, which are fed by solar cells are used as input sources to experiment the response of multilevel inverter with integration of su-percapacitor as a storage device of Renewable Energy System. The RL load is used to compute the time response in MATLABSimulink based environment. With the simulation results a comparative study has been made of two different level types of inverters. Two basic types of inverter are discussed in the study with reference to their electrical behavior. It is also simulated that multilevel inverter can convert stored energy within supercapacitor which is extracted from Renewable Energy System.

  11. Short-term bulk energy storage system scheduling for load leveling in unit commitment: modeling, optimization, and sensitivity analysis.

    Science.gov (United States)

    Hemmati, Reza; Saboori, Hedayat

    2016-05-01

    Energy storage systems (ESSs) have experienced a very rapid growth in recent years and are expected to be a promising tool in order to improving power system reliability and being economically efficient. The ESSs possess many potential benefits in various areas in the electric power systems. One of the main benefits of an ESS, especially a bulk unit, relies on smoothing the load pattern by decreasing on-peak and increasing off-peak loads, known as load leveling. These devices require new methods and tools in order to model and optimize their effects in the power system studies. In this respect, this paper will model bulk ESSs based on the several technical characteristics, introduce the proposed model in the thermal unit commitment (UC) problem, and analyze it with respect to the various sensitive parameters. The technical limitations of the thermal units and transmission network constraints are also considered in the model. The proposed model is a Mixed Integer Linear Programming (MILP) which can be easily solved by strong commercial solvers (for instance CPLEX) and it is appropriate to be used in the practical large scale networks. The results of implementing the proposed model on a test system reveal that proper load leveling through optimum storage scheduling leads to considerable operation cost reduction with respect to the storage system characteristics.

  12. Short-term bulk energy storage system scheduling for load leveling in unit commitment: modeling, optimization, and sensitivity analysis

    Science.gov (United States)

    Hemmati, Reza; Saboori, Hedayat

    2016-01-01

    Energy storage systems (ESSs) have experienced a very rapid growth in recent years and are expected to be a promising tool in order to improving power system reliability and being economically efficient. The ESSs possess many potential benefits in various areas in the electric power systems. One of the main benefits of an ESS, especially a bulk unit, relies on smoothing the load pattern by decreasing on-peak and increasing off-peak loads, known as load leveling. These devices require new methods and tools in order to model and optimize their effects in the power system studies. In this respect, this paper will model bulk ESSs based on the several technical characteristics, introduce the proposed model in the thermal unit commitment (UC) problem, and analyze it with respect to the various sensitive parameters. The technical limitations of the thermal units and transmission network constraints are also considered in the model. The proposed model is a Mixed Integer Linear Programming (MILP) which can be easily solved by strong commercial solvers (for instance CPLEX) and it is appropriate to be used in the practical large scale networks. The results of implementing the proposed model on a test system reveal that proper load leveling through optimum storage scheduling leads to considerable operation cost reduction with respect to the storage system characteristics. PMID:27222741

  13. Prospects of Appliance-Level Load Monitoring in Off-the-Shelf Energy Monitors: A Technical Review

    Directory of Open Access Journals (Sweden)

    Anwar Ul Haq

    2018-01-01

    Full Text Available The smart grid initiative has encouraged utility companies worldwide to roll-out new and smarter versions of energy meters. Before an extensive roll-out, which is both labor-intensive and incurs high capital costs, consumers need to be incentivised to reap the long-term benefits of such smart meters. Off-the-shelf energy monitors (e-monitors can provide consumers with an insight into such potential benefits. As e-monitors are owned by the consumer, the consumer has greater control over the data, which significantly reduces the privacy and data confidentiality concerns. Because only limited online technical information is available about e-monitors, we evaluate several existing e-monitors using an online technical survey directly from the vendors. Besides automated e-monitoring, the use of different off-the-shelf e-monitors can also help to demonstrate state-of-the-art techniques such as non-intrusive load monitoring (NILM, data analytics, and the predictive maintenance of appliances. Our survey indicates a trend towards the incorporation of such state-of-the-art capabilities, particularly the appliance-level e-monitoring and load disaggregation. We have also discussed some essential requirements to implement load disaggregation in the next generation e-monitors. In future, these intelligent e-monitoring techniques will encourage effective consumer participation in the demand-side management (DSM programs.

  14. Development of the advanced load leveling air conditioning technology utilizing unutilized energy; Miriyo energy kodo katsuyo fuka heijunka reidanbo gijutsu no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    A heat supply plant utilizing unutilized energy is called for environment-friendly efficient operation including stable heat supply, energy saving, CO{sub 2} emission control and power load leveling. Toshiba developed the optimum operation system for environment-friendly efficient operation considering heat demand prediction and characteristics of a heat supply plant. The demonstration test result showed that this system is effective to reduce power cost of a heat supply plant by nearly 15%. This system was promoted by joint research of NEDO, Heat Pump and Thermal Storage Technology Center of Japan and Toshiba supported by Agency of Natural Resources and Energy, MITI. (translated by NEDO)

  15. Economic analysis of second use electric vehicle batteries for residential energy storage and load-levelling

    International Nuclear Information System (INIS)

    Heymans, Catherine; Walker, Sean B.; Young, Steven B.; Fowler, Michael

    2014-01-01

    The reuse of Li-ion EV batteries for energy storage systems (ESS) in stationary settings is a promising technology to support improved management of demand and supply of electricity. In this paper, MatLAB simulation of a residential energy profile and regulated cost structure is used to analyze the feasibility of and cost savings from repurposing an EV battery unit for peak-shifting. in situ residential energy storage can contribute to the implementation of a smart grid by supporting the reduction of demand during typical peak use periods. Use of an ESS increases household energy use but potentially improves economic effectiveness and reduces greenhouse gas emissions. The research supports the use of financial incentives for Li-ion battery reuse in ESS, including lower energy rates and reduced auxiliary fees. - Highlights: • EV Li-ion batteries can be reused in stationary energy storage systems (ESS). • A single ESS can shift 2 to 3 h of electricity used in a house. • While energy use increases, potential economic and environmental effectiveness improve. • ESS supports smart grid objectives. • Incentives like reduced fees are needed to encourage implementation of Li-ion battery ESS

  16. 1-GWh diurnal load-leveling superconducting magnetic energy storage system reference design. Appendix D: superconductive magnetic energy storage cavern construction methods and costs

    International Nuclear Information System (INIS)

    1979-09-01

    The excavation and preparation of an underground cavern to contain a 1-GWh diurnal load-leveling Superconducting Magnetic Energy Storage (SMES) unit is examined. The cavern's principal function is to provide a rock structure for supporting the magnetic forces from the charged storage coil. Certain economic considerations indicate the refrigerator cold box for the helium system should also be underground. The study includes such a provision and considers, among other things, rock bolting, water seepage, concrete lining of the walls, steel bearing pads, a system to prevent freezing of the walls, a mining schedule, and costs

  17. Power load leveling and energy saving measures for office buildings. Power load leveling and energy saving technology for the new building of the Kobe branch of the Kansai Electric Power Co., and its effect; Office biru no denryoku fuka heijunka sho energy hosaku. Kobe shiten shinshaoku ni okeru denryoku fuka heijunka sho energy gijutsu to sono koka

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchiyama, M. [Kansai Electric Power Co. Inc., Osaka (Japan)

    1999-06-10

    This paper presents power load leveling and energy saving measures for heat source, air conditioning and lighting of the new Kobe branch building. The low-temperature hot-air system adopts an ice storage system, and reduces blowing power by 12 degreesC blowing in place of normal 16 degreesC blowing, and an initial cost by duct size reduction. The continuous air conditioning system levels an initial peak load of air conditioning as compared with normal air conditioning only for working hours for buildings with large heat capacity. In addition, as power load leveling measures for the whole building, the complete heat storage system using an underground internal melting type ice storage tank is adopted. Energy saving for lighting is achieved with a dimming lighting controlling its lighting output by inverter. The following effects are expected by these new technologies: Load leveling effect of 30%, energy saving effect of 20.2% and CO{sub 2} reduction effect of 24.1%. (NEDO)

  18. Load leveling air conditioning technology development by unused energy high-level utilization. Summary of lectures given at the achievement report meeting; Miriyo energy kodo katsuyo fuka heijunka reidanbo gijutsu kaihatsu. Seika hokokukai koen yoshishu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-01-01

    This paper summarizes lectures given at the research and development achievement report meeting on load leveling air conditioning technologies utilizing unutilized energies at high levels. The lecture titled 'the current status and future problems in heat supply industries' given by the manager of the Heat Supply Industry Department at the Agency of Natural Resources and Energy explained the heat supply businesses in relation with global environment issues, electric power load leveling, and cogeneration. The lecture titled 'improvement of cities to energy saving type cities and district air conditioning systems' given by a construction official at the Ministry of Construction explained the guideline (draft) for introduction of district air conditioning systems as to their purpose, positioning, procedure for discussing the introduction, and procedure for its implementation as a business. The lecture titled 'the recent trend inside and outside the country around unutilized energies' given by Professor Tanazawa at the Tokyo University of Agriculture and Technology described the intensification of energy problems, environment problems, and the near future measures to be taken against these problems. The lecture titled 'summarization of the achievements in development of load leveling air conditioning technologies utilizing unutilized energies at high levels' given by Professor Nakahara at the Kanagawa University explained the summary of the achievements in research and development by themes. (NEDO)

  19. Experimental Results of a DC Bus Voltage Level Control for a Load-Controlled Marine Current Energy Converter

    Directory of Open Access Journals (Sweden)

    Johan Forslund

    2015-05-01

    Full Text Available This paper investigates three load control methods for a  marine current energy converter using a vertical axis current  turbine (VACT mounted on a permanent magnet synchronous generator  (PMSG. The three cases are; a fixed AC load, a fixed pulse width  modulated (PWM DC load and DC bus voltage control of a DC  load. Experimental results show that the DC bus voltage control  reduces the variations of rotational speed by a factor of 3.5 at the cost  of slightly increased losses in the generator and transmission lines.  For all three cases, the tip speed ratio \\(\\lambda\\ can be kept close to  the expected \\(\\lambda_{opt}\\. The power coefficient is estimated to be  0.36 at \\(\\lambda_{opt}\\; however, for all three cases, the average  extracted power was about \\(\\sim 19\\\\%. A maximum power point  tracking (MPPT system, with or without water velocity measurement,  could increase the average extracted power.

  20. A Bi-Level Optimization Approach to Charging Load Regulation of Electric Vehicle Fast Charging Stations Based on a Battery Energy Storage System

    Directory of Open Access Journals (Sweden)

    Yan Bao

    2018-01-01

    Full Text Available Fast charging stations enable the high-powered rapid recharging of electric vehicles. However, these stations also face challenges due to power fluctuations, high peak loads, and low load factors, affecting the reliable and economic operation of charging stations and distribution networks. This paper introduces a battery energy storage system (BESS for charging load control, which is a more user-friendly approach and is more robust to perturbations. With the goals of peak-shaving, total electricity cost reduction, and minimization of variation in the state-of-charge (SOC range, a BESS-based bi-level optimization strategy for the charging load regulation of fast charging stations is proposed in this paper. At the first level, a day-ahead optimization strategy generates the optimal planned load curve and the deviation band to be used as a reference for ensuring multiple control objectives through linear programming, and even for avoiding control failure caused by insufficient BESS energy. Based on this day-ahead optimal plan, at a second level, real-time rolling optimization converts the control process to a multistage decision-making problem. The predictive control-based real-time rolling optimization strategy in the proposed model was used to achieve the above control objectives and maintain battery life. Finally, through a horizontal comparison of two control approaches in each case study, and a longitudinal comparison of the control robustness against different degrees of load disturbances in three cases, the results indicated that the proposed control strategy was able to significantly improve the charging load characteristics, even with large disturbances. Meanwhile, the proposed approach ensures the least amount of variation in the range of battery SOC and reduces the total electricity cost, which will be of a considerable benefit to station operators.

  1. Load leveling air conditioning technology development by unused energy high-level utilization. Summary of achievements by development themes; Miriyo energy kodo katsuyo fuka heijunka reidanbo gijutsu kaihatsu. Kaihatsu temabetsu seika gaiyo

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-01-01

    This paper introduces a number of research and development cases on utilization of unutilized energies. In developing the component technology for a thermal plant utilizing low-temperature unutilized energies, the paper introduces a heat exchanger system to collect heat from sea water, a heat exchanger system to collect heat from waste heated area in subways and urban sewage plants, and a high-density heat transportation system using ice plus water slurry or PCM-C plus water slurry. Furthermore, with regard to the heat pump system using low-temperature unutilized hear sources, development was introduced on a 'heat source load responsive heat pump system', which combines a load variation responsive heat pump utilizing river waters with a latent heat storage system using nighttime electric power serving for electric power load leveling. In developing the component technology for a heat plant utilizing high-temperature unutilized energies, introduction was given on a turbine driven turbo type heat pump system, a high-efficiency absorption type heat pump, a waste heat driven absorption type freezer, and an urban type underground heat storage tank. (NEDO)

  2. Load leveling on industrial refrigeration systems

    Science.gov (United States)

    Bierenbaum, H. S.; Kraus, A. D.

    1982-01-01

    A computer model was constructed of a brewery with a 2000 horsepower compressor/refrigeration system. The various conservation and load management options were simulated using the validated model. The savings available for implementing the most promising options were verified by trials in the brewery. Result show that an optimized methodology for implementing load leveling and energy conservation consisted of: (1) adjusting (or tuning) refrigeration systems controller variables to minimize unnecessary compressor starts, (2) The primary refrigeration system operating parameters, compressor suction pressure, and discharge pressure are carefully controlled (modulated) to satisfy product quality constraints (as well as in-process material cooling rates and temperature levels) and energy evaluating the energy cost savings associated with reject heat recovery, and (4) a decision is made to implement the reject heat recovery system based on a cost/benefits analysis.

  3. RF Loads for Energy Recovery

    CERN Document Server

    Federmann, S; Caspers, F

    2012-01-01

    Different conceptional designs for RF high power loads are presented. One concept implies the use of solid state rectifier modules for direct RF to DC conversion with efficiencies beyond 80%. In addition, robust metallic low-Q resonant structures, capable of operating at high temperatures (>150 ◦C) are discussed. Another design deals with a very high temperature (up to 800 ◦C) air cooled load using a ceramic foam block inside a metal enclosure. This porous ceramic block is the microwave absorber and is not brazed to the metallic enclosure.

  4. 1-GWh diurnal load-leveling Superconducting Magnetic Energy Storage System reference design. Appendix G. Design study. Thyristor converter stations for use with superconducting magnetic energy storage systems

    International Nuclear Information System (INIS)

    Lindh, C.B.; Pohl, R.V.; Trojan, H.T.

    1979-09-01

    The cost for the power conversion equipment for four different SMES systems were developed. These were 1- and 5-GWh units for 4- and 8-h charge periods. Only constant power operation of the converter was considered with 10% of the maximum energy remaining in the magnet at the end of the discharge cycle. The cost increases almost linearly with the maximum coil current between 30 kA and 150 kA, and the cost for a 4-h charge system is about 20% lower than for an 8-h charge system. The converter terminal cost is estimated to be $40/kW of installed power for a 1-GWh 4-h charge system at 30 kA maximum current and $60/kW of installed power for a 5-GWh 4-h charge system at 50 kA maximum current

  5. How to tackle energy saving and load leveling. Energy saving towards 2000 and measures for the coming winter (energy-saving activities by California`s SCE, demand side management activities); Sho energy fuka heijunka ni do torikumuka. Seireki 2000 nen ni muketa sho energy to konto no shoene taisaku, Kashu SCE no sho energy (DSM katsudo wo saguru)

    Energy Technology Data Exchange (ETDEWEB)

    Nasu, S. [The Energy Conservation Center Japan, Tokyo (Japan)

    1997-02-01

    Tokyo Electric Power has realized a peak shift of 5% for the maximum power demand by various measures to cope with increasing power demand and differential rate by time zone, including expansion of the differential rate system and heat-storage systems. Some of more notable recent techniques are eco-ice and eco-vendor systems, the former storing ice in the heat-storage tanks and the latter strongly cooling vending machines during nighttime. The NAS battery system is being developed as the new technique for load leveling. The energy-related advisory organ for Minister of International Trade and Industry asks each industrial unit to save at least 1% of power on the annual average as the energy-saving measure towards 2000. The energy-saving measures promoted by the government for the coming winter are controlled release of wastes, efficient use of power, setting room temperature at 19{degree}C or lower and voluntarily refrain from commuting by cars. The US power industry is abandoning the concept of DSM in the midst of deregulation and increased competition, and cutting budgets for new energy development. California`s SCE is promoting energy-saving through expanded use of high-efficiency motors, accurate grasp of customers` needs and publicity activities through internet systems. 4 figs., 1 tab.

  6. Energy conservation prospects through electric load management

    Energy Technology Data Exchange (ETDEWEB)

    El-Shirbeeny, E H.T.

    1984-04-01

    In this paper, concepts of electric load management are discussed for effective energy conservation. It is shown that the conservation program must be comprehensive to provide solutions to the problems facing the electric consumer, the electric utility and the society by reducing the rate of growth of energy consumption and power system peak demand requirements. The impact of energy management programs on electric energy conservation is examined, with emphasis on efficiency, storage, cogeneration and controls with computers.

  7. Energy efficiency and load curve impacts

    International Nuclear Information System (INIS)

    Feilberg, Nicolai

    2002-01-01

    One of SINTEF Energy Research's European RTD projects is the two-year EFFLOCOM (Energy EFFiciency and LOad curve impacts of COMmercial development in competitive markets). This project will determine the end-user response of different market-related services offered in deregulated power markets. The project will investigate the possibility of influencing load curves by using different price signals and two-way communications via Internet. The partners are from Denmark. Finland, England, France and Norway. SINTEF Energy Research is in charge of the project management. During the project, the changes in load curves will he studied in the in the participating countries before and after deregulation. Specific issues are the use of ICT, time- and situation-dependent tariffs and smart-house technology. The project will consist of 5 work packages that will give recommendations about new methods, guidelines and tools to promote effective use of energy in the partner countries. The total budget is EUR 692 000. (author)

  8. Level best : drilling seasonal load leveling business case : final report

    International Nuclear Information System (INIS)

    2005-10-01

    Drilling and seismic costs in Western Canada are as much as 35 per cent higher during winter months. Favourable commodity pricing has prompted aggressive expansion of drilling programs in the Western Canada Sedimentary Basin (WCSB), and capacity is becoming a significant issue. Many operators are turning to load leveling in order to secure rigs and crew availability. However, many operators still adhere to the traditional view that drilling of oil and gas wells is best accomplished during the winter. The purpose of the project discussed in this paper was to develop and present a business case for greater seasonal load leveling in the WCSB and spreading it more evenly throughout the year. Using calendar year quarters, publicly available data for a 5 year period from 2000-2004 for drilling activity, safety, weather, and environmental restrictions were examined. A list of candidate fields with high levels of activity and a good representation of well depths was selected. Well cost and rig data from 14 different companies was used. A variety of industry participants, drilling contractors, load leveling technology suppliers and provincial agencies were consulted to supplement well cost analyses. The financial impacts of load leveling were examined. Benefits included lower well costs; advanced production; avoided rig construction; reduced incident rates; and reduced turnover. While the focus of the business case for load leveling was based on hard cost data, many indirect benefits were identified, including First Nations sustainability and greater job security and comfort for workers. Various policies and incentives that encouraged load leveling in British Columbia and Alberta were reviewed. 57 figs

  9. Wind loads on solar energy roofs

    NARCIS (Netherlands)

    Geurts, C.P.W.; Bentum, C.A. van

    2007-01-01

    This paper presents an overview of the wind loads on roofs, equipped with solar energy products, so called Active Roofs. Values given in this paper have been based on wind tunnel and full scale measurements, carried out at TNO, and on an interpretation of existing rules and guidelines. The results

  10. Correlation between renew able energy source's energy output and load

    International Nuclear Information System (INIS)

    Ali, G.H.M.; El-Zeftawy, A.A.

    1996-01-01

    The common problem to all renew energy sources (RESs) is the mismatch between their energy output and load demand. In remote areas, the solution of this problem is in general employing a small diesel-generator or a storage battery. But, the storage battery is a major cost element of RESs and small diesel-generator is unreliable and costly. Therefore, a proposed technique has been introduced in this work to determine correlation between the energy output of wind energy systems (WES) and isolated loads. solar photovoltaic power system (PVS) and two of energy storage facilities are used here for this correlation. The proposed technique includes also two models for optimizing the generation and costs of WES accompanied with PVS, storage battery and water storage (reservoir) to accommodate an isolated load. The proposed technique is applied with the dynamic programming to coordinate the energy output of a WES with residential and pumping load in remote area of egypt. The results of this application reveal that minimization of both capacity of the storage battery and the whole power system cost are obtained. 4 figs

  11. Specific Energy of Hard Coal Under Load

    Directory of Open Access Journals (Sweden)

    Bogusz Anna

    2015-03-01

    Full Text Available The article presents results of experimental tests of energy parameters of hard coals under loading, collected from research sites located within five main geologic structures of Upper Silesian Coal Basin (GZW - Main Trough, Main Anticline, Bytom Trough, Rybnik Trough and Chwałowice Trough. Coals from12 mines were analysed, starting with seams of group 200, through groups 400, 500, 600 and, finally, seams of group 700. Coal of each of the groups of seams underwent uniaxial compression stress of the energy parameters, in a servo-controlled testing machine MTS-810NEW, for the full range of strain of the tested coal samples. Based on the tests the dependence of different types of specific energy of longitudinal strain of coals on the value of uniaxial compression strength was determined. The dependence of the value of dissipated energy and kinetic energy of coals on the uniaxial compression strength was described with a linear function, both for coals which due to their age belong to various bed sand for various lithotypes of coal. An increase in the value of dissipated energy and in kinetic energy was observed, which was correlated with an increase in uniaxial compression strength of coal. The share of dissipated energy is dominant in the total energy of strain. Share of recoverable energy in the total energy of strain is small, independent of the compression strength of coals and is at most a few per cent high. In coals of low strength and dominant share of dissipated energy, share of recoverable energy is the biggest among the tested coals. It was shown that following an increase in compression strength the share of recoverable energy decreases, while the share of dissipated energy in the total energy increases. Further studies of specific energy of longitudinal strain of rocks in the full-range strain will be the next step inperfecting methodology of research into natural rock burst susceptibility of Carboniferous rock mass and changes in the

  12. Energy efficiency analysis of reconfigured distribution system for practical loads

    Directory of Open Access Journals (Sweden)

    Pawan Kumar

    2016-09-01

    Full Text Available In deregulated rate structure, the performance evaluation of distribution system for energy efficiency includes; loss minimization, improved power quality, loadability limit, reliability and availability of supply. Energy efficiency changes with the variation in loading pattern and the load behaviour. Further, the nature of load at each node is not explicitly of any one type rather their characteristics depend upon the node voltages. In most cases, load is assumed to be constant power (real and reactive. In this paper voltage dependent practical loads are represented with composite load model and the energy efficiency performance of distribution system for practical loads is evaluated in different configurations of 33-node system.

  13. Actual conditions of energy management in office buildings; Results of quetionaire inquiry about load leveling. Gyomu yo biru ni okeru energy kanri no jittai ni tsuite; Fuka heijunka ni kakawaru anketo chosa kekka

    Energy Technology Data Exchange (ETDEWEB)

    Okubo, Katsuhiko (The Inst. of Applied Energy, Tokyo, (Japan))

    1989-07-20

    The electric power demand in Japan is increasing, and it is expected that annual load factor shows decreasing tendency. All electric power companies endeavor to improve load leveling than as it was, and intend to introduce direct saving system to control the loading equipments of consumers as well as indirect control such as midnight power system. Therefore, quetionaire inquiry about this new system was made for business power consumers in which power there are much difference in consumed power between day and night and much efficacy for power saving. As the results of the inquiry, it was understood that equipment of automatic or remote control for loading equipments were already introduced by many consumers and adoption of airconditioners controlled at every floor or every room is increased. So, about the control of the equipments in cosumers a method is also required so that electric power companies shall control the maximum demand by consumers and selection of control equipments are left on consumers' decision and judgment, and it is considered to be important that control by electric power companies shall not only turn on or off switchs but also realize convenience and economy of consumers. 9 figs., 3 tabs.

  14. Energy efficiency indicators for high electric-load buildings

    Energy Technology Data Exchange (ETDEWEB)

    Aebischer, Bernard; Balmer, Markus A.; Kinney, Satkartar; Le Strat, Pascale; Shibata, Yoshiaki; Varone, Frederic

    2003-06-01

    Energy per unit of floor area is not an adequate indicator for energy efficiency in high electric-load buildings. For two activities, restaurants and computer centres, alternative indicators for energy efficiency are discussed.

  15. Impaired brain energy gain upon a glucose load in obesity.

    Science.gov (United States)

    Wardzinski, Ewelina K; Kistenmacher, Alina; Melchert, Uwe H; Jauch-Chara, Kamila; Oltmanns, Kerstin M

    2018-03-06

    There is evidence that the brain's energy status is lowered in obesity despite of chronic hypercaloric nutrition. The underlying mechanisms are unknown. We hypothesized that the brain of obese people does not appropriately generate energy in response to a hypercaloric supply. Glucose was intravenously infused in 17 normal weights and 13 obese participants until blood glucose concentrations reached the postprandial levels of 7 mmol/L and 10 mmol/L. Changes in cerebral adenosine triphosphate (ATP) and phosphocreatine (PCr) content were measured by 31 phosphorus magnetic resonance spectroscopy and stress hormonal measures regulating glucose homeostasis were monitored. Because vitamin C is crucial for a proper neuronal energy synthesis we determined circulating concentrations during the experimental testing. Cerebral high-energy phosphates were increased at blood glucose levels of 7 mmol/L in normal weights, which was completely missing in the obese. Brain energy content moderately raised only at blood glucose levels of 10 mmol/L in obese participants. Vitamin C concentrations generally correlated with the brain energy content at blood glucose concentrations of 7 mmol/L. Our data demonstrate an inefficient cerebral energy gain upon a glucose load in obese men, which may result from a dysfunctional glucose transport across the blood-brain barrier or a downregulated energy synthesis in mitochondrial oxidation processes. Our finding offers an explanation for the chronic neuroenergetic deficiency and respectively missing satiety perception in obesity. Copyright © 2018. Published by Elsevier Inc.

  16. 1-GWh diurnal load-leveling superconducting magnetic energy storage system reference design. Appendix B: cost study, high-purity aluminum production

    International Nuclear Information System (INIS)

    Cochran, C.N.; Dawless, R.K.; Whitchurch, J.B.

    1979-09-01

    Cost information is supplied for aluminum with purities of 200, 2000, and 5000 residual resistivity ratio. Two production situations were used for each purity: (1) 1 x 10 6 kg/yr production rate with a 30-yr sustaining market and (2) 1 x 10 6 kg/yr production rate for 2 yrs only. These productions and purities are of interest for manufacturing devices for Superconducting Magnetic Energy Storage. The cost study results are presented as a range and include (1) the selling price of the aluminum for each case, (2) the cost of facilities including construction, engineering, and related costs, (3) the cost of money and depreciation (interest/amortization), and (4) the energy costs - the total of power and fuel. The range is affected by possible production variations and other uncertainties. Information is also given on plant location options and the preferred feed to the purification facility

  17. Energy levels of 56Mn

    DEFF Research Database (Denmark)

    Van Assche, P. H. M.; Baader, H. A.; Koch, H. R.

    1971-01-01

    The low-energy spectrum of the 55Mn(n,γ)56 Mn reaction has been studied with a γ-diffraction spectrometer. These data allowed the construction of a level scheme for 56Mn with two previously unobserved doublets. High-energy γ-transitions to the low-energy states have been measured for different...

  18. Net load forecasting for high renewable energy penetration grids

    International Nuclear Information System (INIS)

    Kaur, Amanpreet; Nonnenmacher, Lukas; Coimbra, Carlos F.M.

    2016-01-01

    We discuss methods for net load forecasting and their significance for operation and management of power grids with high renewable energy penetration. Net load forecasting is an enabling technology for the integration of microgrid fleets with the macrogrid. Net load represents the load that is traded between the grids (microgrid and utility grid). It is important for resource allocation and electricity market participation at the point of common coupling between the interconnected grids. We compare two inherently different approaches: additive and integrated net load forecast models. The proposed methodologies are validated on a microgrid with 33% annual renewable energy (solar) penetration. A heuristics based solar forecasting technique is proposed, achieving skill of 24.20%. The integrated solar and load forecasting model outperforms the additive model by 10.69% and the uncertainty range for the additive model is larger than the integrated model by 2.2%. Thus, for grid applications an integrated forecast model is recommended. We find that the net load forecast errors and the solar forecasting errors are cointegrated with a common stochastic drift. This is useful for future planning and modeling because the solar energy time-series allows to infer important features of the net load time-series, such as expected variability and uncertainty. - Highlights: • Net load forecasting methods for grids with renewable energy generation are discussed. • Integrated solar and load forecasting outperforms the additive model by 10.69%. • Net load forecasting reduces the uncertainty between the interconnected grids.

  19. Magnesium Hydride for Load Levelling Energy Storage

    DEFF Research Database (Denmark)

    Vigeholm, B.

    Some of the magnesium properties essential to the applicability of the reaction Mg+H2⇆MgH2 as a hydrogen storage system have been investigated. Three magnesium powders with particle size smaller than 50 μm average diameter were cycled, over 31, 71 and 151 cycles respectively, at 675K (400°C...

  20. Bed-levelling experiments with suspended load

    NARCIS (Netherlands)

    Talmon, A.M.; De Graaff, J.

    1991-01-01

    Bed-levelling experiments are conducted in a straight laboratory channel. The experiments involve a significant fraction of suspended sediment transport. The purpose of the experiments is to provide data for modelling of the direction of sediment transport on a transverse sloping alluvial river bed,

  1. Energy absorption capabilities of composite sandwich panels under blast loads

    Science.gov (United States)

    Sankar Ray, Tirtha

    As blast threats on military and civilian structures continue to be a significant concern, there remains a need for improved design strategies to increase blast resistance capabilities. The approach to blast resistance proposed here is focused on dissipating the high levels of pressure induced during a blast through maximizing the potential for energy absorption of composite sandwich panels, which are a competitive structural member type due to the inherent energy absorption capabilities of fiber reinforced polymer (FRP) composites. Furthermore, the middle core in the sandwich panels can be designed as a sacrificial layer allowing for a significant amount of deformation or progressive failure to maximize the potential for energy absorption. The research here is aimed at the optimization of composite sandwich panels for blast mitigation via energy absorption mechanisms. The energy absorption mechanisms considered include absorbed strain energy due to inelastic deformation as well as energy dissipation through progressive failure of the core of the sandwich panels. The methods employed in the research consist of a combination of experimentally-validated finite element analysis (FEA) and the derivation and use of a simplified analytical model. The key components of the scope of work then includes: establishment of quantified energy absorption criteria, validation of the selected FE modeling techniques, development of the simplified analytical model, investigation of influential core architectures and geometric parameters, and investigation of influential material properties. For the parameters that are identified as being most-influential, recommended values for these parameters are suggested in conceptual terms that are conducive to designing composite sandwich panels for various blast threats. Based on reviewing the energy response characteristic of the panel under blast loading, a non-dimensional parameter AET/ ET (absorbed energy, AET, normalized by total energy

  2. Energy loading effects in the scaling of atomic xenon lasers

    International Nuclear Information System (INIS)

    Ohwa, M.; Kushner, M.J.

    1990-01-01

    The intrinsic power efficiency of the atomic xenon (5d → 6p) infrared (1.73--3.65 μm) laser is sensitive to the rate of pumping due to electron collision mixing of the laser levels. Long duration pumping at moderate power deposition may therefore result in higher energy efficiencies than pumping at higher powers. In this paper the authors examine the consequences of high energy deposition (100's J/1 atm) during long pumping pulses (100's μs) on the intrinsic power and energy efficiency and optimum power deposition of the atomic xenon laser. The dominant effect of high energy loading, gas heating, causes an increase in the electron density and therefore an increase in the electron collision mixing of the laser levels. The optimum power deposition for a given gas density therefore shifts to lower values with increasing gas temperature. For sufficiently long pumping pulses, nonuniform gas heating results in convection and rarification of highly pumped regions. The optimum power deposition therefore shifts to even lower values as the length of the pumping pulse increases. As a result, laser efficiency depends on the spatial distribution of power deposition as well as its magnitude

  3. High level waste at Hanford: Potential for waste loading maximization

    International Nuclear Information System (INIS)

    Hrma, P.R.; Bailey, A.W.

    1995-09-01

    The loading of Hanford nuclear waste in borosilicate glass is limited by phase-related phenomena, such as crystallization or formation of immiscible liquids, and by breakdown of the glass structure because of an excessive concentration of modifiers. The phase-related phenomena cause both processing and product quality problems. The deterioration of product durability determines the ultimate waste loading limit if all processing problems are resolved. Concrete examples and mass-balance based calculations show that a substantial potential exists for increasing waste loading of high-level wastes that contain a large fraction of refractory components

  4. Peak loads and network investments in sustainable energy transitions

    Energy Technology Data Exchange (ETDEWEB)

    Blokhuis, Erik, E-mail: e.g.j.blokhuis@tue.nl [Eindhoven University of Technology, Department of Architecture, Building and Planning, Vertigo 8.11, P.O. Box 513, 5600MB Eindhoven (Netherlands); Brouwers, Bart [Eindhoven University of Technology, Department of Architecture, Building and Planning, Vertigo 8.11, P.O. Box 513, 5600MB Eindhoven (Netherlands); Putten, Eric van der [Endinet, Gas and Electricity Network Operations, P.O. Box 2005, 5600CA Eindhoven (Netherlands); Schaefer, Wim [Eindhoven University of Technology, Department of Architecture, Building and Planning, Vertigo 8.11, P.O. Box 513, 5600MB Eindhoven (Netherlands)

    2011-10-15

    Current energy distribution networks are often not equipped for facilitating expected sustainable transitions. Major concerns for future electricity networks are the possibility of peak load increases and the expected growth of decentralized energy generation. In this article, we focus on peak load increases; the effects of possible future developments on peak loads are studied, together with the consequences for the network. The city of Eindhoven (the Netherlands) is used as reference city, for which a scenario is developed in which the assumed future developments adversely influence the maximum peak loads on the network. In this scenario, the total electricity peak load in Eindhoven is expected to increase from 198 MVA in 2009 to 591-633 MVA in 2040. The necessary investments for facilitating the expected increased peak loads are estimated at 305-375 million Euros. Based upon these projections, it is advocated that - contrary to current Dutch policy - choices regarding sustainable transitions should be made from the viewpoint of integral energy systems, evaluating economic implications of changes to generation, grid development, and consumption. Recently applied and finished policies on energy demand reduction showed to be effective; however, additional and connecting policies on energy generation and distribution should be considered on short term. - Highlights: > Sustainable energy transitions can result in major electricity peak load increases. > Introduction of heat pumps and electrical vehicles requires network expansion. > Under worst case assumptions, peak loads in Eindhoven increase with 200% until 2040. > The necessary investment for facilitating this 2040 peak demand is Euro 305-375 million. > Future policy choices should be made from the viewpoint of the integral energy system.

  5. Peak loads and network investments in sustainable energy transitions

    International Nuclear Information System (INIS)

    Blokhuis, Erik; Brouwers, Bart; Putten, Eric van der; Schaefer, Wim

    2011-01-01

    Current energy distribution networks are often not equipped for facilitating expected sustainable transitions. Major concerns for future electricity networks are the possibility of peak load increases and the expected growth of decentralized energy generation. In this article, we focus on peak load increases; the effects of possible future developments on peak loads are studied, together with the consequences for the network. The city of Eindhoven (the Netherlands) is used as reference city, for which a scenario is developed in which the assumed future developments adversely influence the maximum peak loads on the network. In this scenario, the total electricity peak load in Eindhoven is expected to increase from 198 MVA in 2009 to 591-633 MVA in 2040. The necessary investments for facilitating the expected increased peak loads are estimated at 305-375 million Euros. Based upon these projections, it is advocated that - contrary to current Dutch policy - choices regarding sustainable transitions should be made from the viewpoint of integral energy systems, evaluating economic implications of changes to generation, grid development, and consumption. Recently applied and finished policies on energy demand reduction showed to be effective; however, additional and connecting policies on energy generation and distribution should be considered on short term. - Highlights: → Sustainable energy transitions can result in major electricity peak load increases. → Introduction of heat pumps and electrical vehicles requires network expansion. → Under worst case assumptions, peak loads in Eindhoven increase with 200% until 2040. → The necessary investment for facilitating this 2040 peak demand is Euro 305-375 million. → Future policy choices should be made from the viewpoint of the integral energy system.

  6. Effect of density and weight of load on the energy cost of carrying loads by donkeys and ponies.

    Science.gov (United States)

    Pearson, R A; Dijkman, J T; Krecek, R C; Wright, P

    1998-02-01

    Two experiments were designed to compare the energy used in carrying loads by donkeys and ponies. In the first experiment 3 donkeys and 3 ponies were compared on treadmills in the UK. Density of load (lead shot or straw) had no significant effect on the energy cost of carrying loads; however, the energy cost of carrying a load decreased significantly (p < 0.001) as the weight of the load increased (in donkeys 6.44, 4.35 and 3.03 J/kg load/m, in ponies 5.82, 3.75 and 3.68 J/kg load/m, for loads of 13, 20 and 27 kg/100 kg liveweight (M) respectively). Differences between species were not significant. In the second experiment energy expenditures were determined in 3 donkeys carrying loads equivalent to 40 kg/100 kg M over gently undulating gravel tracks in Tunisia. Energy costs of carrying the load were 2.34 (SE 0.07) J/kg load/m. The results of both experiments showed that provided the load is balanced, density does not significantly affect the energy cost of carrying; however, as the load increased then the unit energy cost of carrying it decreased. This suggest that it is more efficient in terms of energy used to carry loads equivalent to 27 to 40 kg/100 kg M than it is to carry lighter loads to less than 20 kg/100 kg M.

  7. Energy consumption program: A computer model simulating energy loads in buildings

    Science.gov (United States)

    Stoller, F. W.; Lansing, F. L.; Chai, V. W.; Higgins, S.

    1978-01-01

    The JPL energy consumption computer program developed as a useful tool in the on-going building modification studies in the DSN energy conservation project is described. The program simulates building heating and cooling loads and computes thermal and electric energy consumption and cost. The accuracy of computations are not sacrificed, however, since the results lie within + or - 10 percent margin compared to those read from energy meters. The program is carefully structured to reduce both user's time and running cost by asking minimum information from the user and reducing many internal time-consuming computational loops. Many unique features were added to handle two-level electronics control rooms not found in any other program.

  8. Economics of Renewable Energy Integration and Energy Storage via Low Load Diesel Application

    Directory of Open Access Journals (Sweden)

    James Hamilton

    2018-04-01

    Full Text Available One-quarter of the world’s population lives without access to electricity. Unfortunately, the generation technology most commonly employed to advance rural electrification, diesel generation, carries considerable commercial and ecological risks. One approach used to address both the cost and pollution of diesel generation is renewable energy (RE integration. However, to successfully integrate RE, both the stochastic nature of the RE resource and the operating characteristics of diesel generation require careful consideration. Typically, diesel generation is configured to run heavily loaded, achieving peak efficiencies within 70–80% of rated capacity. Diesel generation is also commonly sized to peak demand. These characteristics serve to constrain the possible RE penetration. While energy storage can relieve the constraint, this adds cost and complexity to the system. This paper identifies an alternative approach, redefining the low load capability of diesel generation. Low load diesel (LLD allows a diesel engine to operate across its full capacity in support of improved RE utilization. LLD uses existing diesel assets, resulting in a reduced-cost, low-complexity substitute. This paper presents an economic analysis of LLD, with results compared to conventional energy storage applications. The results identify a novel pathway for consumers to transition from low to medium levels of RE penetration, without additional cost or system complexity.

  9. Calculation approaches for grid usage fees to influence the load curve in the distribution grid level

    International Nuclear Information System (INIS)

    Illing, Bjoern

    2014-01-01

    Dominated by the energy policy the decentralized German energy market is changing. One mature target of the government is to increase the contribution of renewable generation to the gross electricity consumption. In order to achieve this target disadvantages like an increased need for capacity management occurs. Load reduction and variable grid fees offer the grid operator solutions to realize capacity management by influencing the load profile. The evolution of the current grid fees towards more causality is required to adapt these approaches. Two calculation approaches are developed in this assignment. On the one hand multivariable grid fees keeping the current components demand and energy charge. Additional to the grid costs grid load dependent parameters like the amount of decentralized feed-ins, time and local circumstances as well as grid capacities are considered. On the other hand the grid fee flat-rate which represents a demand based model on a monthly level. Both approaches are designed to meet the criteria for future grid fees. By means of a case study the effects of the grid fees on the load profile at the low voltage grid is simulated. Thereby the consumption is represented by different behaviour models and the results are scaled at the benchmark grid area. The resulting load curve is analyzed concerning the effects of peak load reduction as well as the integration of renewable energy sources. Additionally the combined effect of grid fees and electricity tariffs is evaluated. Finally the work discusses the launching of grid fees in the tense atmosphere of politics, legislation and grid operation. Results of this work are two calculation approaches designed for grid operators to define the grid fees. Multivariable grid fees are based on the current calculation scheme. Hereby demand and energy charges are weighted by time, locational and load related dependencies. The grid fee flat-rate defines a limitation in demand extraction. Different demand levels

  10. Load Matching and Grid Interaction of Net Zero Energy Buildings

    DEFF Research Database (Denmark)

    Voss, Karsten; Candanedo, José A.; Geier, Sonja

    2010-01-01

    of seasonal energy storage on-site. Even though the wording “Net Zero Energy Building” focuses on the annual energy balance, large differences may occur between solution sets in the amount of grid interaction needed to reach the goal. The paper reports on the analysis of example buildings concerning the load......“Net Zero Energy Building” has become a prominent wording to describe the synergy of energy efficient building and renewable energy utilization to reach a balanced energy budget over a yearly cycle. Taking into account the energy exchange with a grid infrastructure overcomes the limitations...... matching and grid interaction. Indices to describe both issues are proposed and foreseen as part of a harmonized definition framework. The work is part of subtask A of the IEA SHCP Task40/ECBCS Annex 52: “Towards Net Zero Energy Solar Buildings”....

  11. Wave loadings acting on Overtopping Breakwater for Energy Conversion

    DEFF Research Database (Denmark)

    Vicinanza, Diego; Nørgaard, Jørgen Harck; Contestabile, Pasquale

    2013-01-01

    distributions. Load measurements were compared with the most used prediction method for traditional breakwaters, available in the Coastal Engineering Manual (U.S. Army Corps of Engineers, 2002). These results suggest to use the experimental data as design loadings since the design criteria for the innovative......Any kind of Wave Energy Converter (WEC) requires information on reliability of technology and on time required for the return of the investment (reasonable payback). The structural response is one of the most important parameters to take in to account for a consistent assessment on innovative...... devices. This paper presents results on wave loading acting on an hybrid WEC named Overtopping BReakwater for Energy Conversion (OBREC). The new design is based on the concept of an integration between a traditional rubble mound breakwater and a front reservoir designed to store the wave overtopping from...

  12. Wave Induced Loads on the LEANCON Wave Energy Converter

    DEFF Research Database (Denmark)

    Frigaard, Peter; Kofoed, Jens Peter; Beserra, Eliab Ricarte

    This report is a product of the co-operation agreement between Aalborg University and LEANCON (by Kurt Due Rasmussen) on the evaluation and development of the LEANCON wave energy converter (WEC). The work reported here has focused on evaluation of the wave induced loads on the device, based...... in the laboratory, all under the supervision of the personnel of the Wave Energy Research Group at Department of Civil Engineering, Aalborg University....

  13. Comparison of Building Energy Modeling Programs: Building Loads

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Dandan [Tsinghua Univ., Beijing (China); Hong, Tianzhen [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Yan, Da [Tsinghua Univ., Beijing (China); Wang, Chuang [Tsinghua Univ., Beijing (China)

    2012-06-01

    This technical report presented the methodologies, processes, and results of comparing three Building Energy Modeling Programs (BEMPs) for load calculations: EnergyPlus, DeST and DOE-2.1E. This joint effort, between Lawrence Berkeley National Laboratory, USA and Tsinghua University, China, was part of research projects under the US-China Clean Energy Research Center on Building Energy Efficiency (CERC-BEE). Energy Foundation, an industrial partner of CERC-BEE, was the co-sponsor of this study work. It is widely known that large discrepancies in simulation results can exist between different BEMPs. The result is a lack of confidence in building simulation amongst many users and stakeholders. In the fields of building energy code development and energy labeling programs where building simulation plays a key role, there are also confusing and misleading claims that some BEMPs are better than others. In order to address these problems, it is essential to identify and understand differences between widely-used BEMPs, and the impact of these differences on load simulation results, by detailed comparisons of these BEMPs from source code to results. The primary goal of this work was to research methods and processes that would allow a thorough scientific comparison of the BEMPs. The secondary goal was to provide a list of strengths and weaknesses for each BEMP, based on in-depth understandings of their modeling capabilities, mathematical algorithms, advantages and limitations. This is to guide the use of BEMPs in the design and retrofit of buildings, especially to support China’s building energy standard development and energy labeling program. The research findings could also serve as a good reference to improve the modeling capabilities and applications of the three BEMPs. The methodologies, processes, and analyses employed in the comparison work could also be used to compare other programs. The load calculation method of each program was analyzed and compared to

  14. Renewable energy load assessment for Boquillas Del Carmen Coahuila, Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Foster, R. [Southwest Technology Development Institute, Las Cruces, NM (United States)

    1995-08-01

    This report outlines the estimates that were made in 1992 of the potential load requirements for Boquillas del Carmen, a small Mexican village on the northern border of the state of Coahuila, Mexico near Big Bend National Park in southern Texas. The study was made to help determine the possibility that village might be electrified by solar or wind energy. Various estimates of are given of the potential load based on estimates ranging from basic use of lights, radio, television, and small household appliances to microwave ovens, refrigerators, and direct evaporative coolers. The low-energy consumption case was estimated to be at 23.0 kWh/month per residence per month, and the high-energy consumption case (with cooling) was 140.7 kWh/month per residence. On average, the typical residence is occupied by five individuals.

  15. Load Reduction, Demand Response and Energy Efficient Technologies and Strategies

    Energy Technology Data Exchange (ETDEWEB)

    Boyd, Paul A.; Parker, Graham B.; Hatley, Darrel D.

    2008-11-19

    The Department of Energy’s (DOE’s) Pacific Northwest National Laboratory (PNNL) was tasked by the DOE Office of Electricity (OE) to recommend load reduction and grid integration strategies, and identify additional demand response (energy efficiency/conservation opportunities) and strategies at the Forest City Housing (FCH) redevelopment at Pearl Harbor and the Marine Corps Base Hawaii (MCBH) at Kaneohe Bay. The goal was to provide FCH staff a path forward to manage their electricity load and thus reduce costs at these FCH family housing developments. The initial focus of the work was at the MCBH given the MCBH has a demand-ratchet tariff, relatively high demand (~18 MW) and a commensurate high blended electricity rate (26 cents/kWh). The peak demand for MCBH occurs in July-August. And, on average, family housing at MCBH contributes ~36% to the MCBH total energy consumption. Thus, a significant load reduction in family housing can have a considerable impact on the overall site load. Based on a site visit to the MCBH and meetings with MCBH installation, FCH, and Hawaiian Electric Company (HECO) staff, recommended actions (including a "smart grid" recommendation) that can be undertaken by FCH to manage and reduce peak-demand in family housing are made. Recommendations are also made to reduce overall energy consumption, and thus reduce demand in FCH family housing.

  16. Electric utility load management: rational use of energy program pilot study

    Energy Technology Data Exchange (ETDEWEB)

    1977-08-01

    In recognition of the role that load management can play in ensuring that the growing demand for electricity is met in a cost- and energy-efficient manner, in mid-1974, the NATO Committee on the Challenges of Modern Society sponsored all three meetings to provide a forum for representatives of U.S. and European utilities to exchange views and experiences on the various aspects of load management. It was the consensus of representatives at the meetings that three overall approaches offer significant opportunities for achieving improved load management: development of marginal-cost rate structures; power pooling and energy storage by utilities; and efforts by consumers. Industrial consumers can assist electric utilities in their efforts to level system loads through three important methods: interruptible power and deferred load control; peak self-generation; and shifts in operating schedules. Residential/commercial consumers also have an important role to play by managing both their electric heating load (through the interruption of direct-resistance heating and the storage of heat) and their air conditioning load. In response to the interest expressed by the participants in the CCMS conferences, the U.S. and several European governments, national electric utility industry organizations, state public utility commissions, and many individual utilities have undertaken R and D projects to investigate and test various aspects of these three approaches to load management. This report describes the projects that were presented by the utility representatives.

  17. Lambda-Based Data Processing Architecture for Two-Level Load Forecasting in Residential Buildings

    Directory of Open Access Journals (Sweden)

    Gde Dharma Nugraha

    2018-03-01

    Full Text Available Building energy management systems (BEMS have been intensively used to manage the electricity consumption of residential buildings more efficiently. However, the dynamic behavior of the occupants introduces uncertainty problems that affect the performance of the BEMS. To address this uncertainty problem, the BEMS may implement load forecasting as one of the BEMS modules. Load forecasting utilizes historical load data to compute model predictions for a specific time in the future. Recently, smart meters have been introduced to collect electricity consumption data. Smart meters not only capture aggregation data, but also individual data that is more frequently close to real-time. The processing of both smart meter data types for load forecasting can enhance the performance of the BEMS when confronted with uncertainty problems. The collection of smart meter data can be processed using a batch approach for short-term load forecasting, while the real-time smart meter data can be processed for very short-term load forecasting, which adjusts the short-term load forecasting to adapt to the dynamic behavior of the occupants. This approach requires different data processing techniques for aggregation and individual of smart meter data. In this paper, we propose Lambda-based data processing architecture to process the different types of smart meter data and implement the two-level load forecasting approach, which combines short-term and very short-term load forecasting techniques on top of our proposed data processing architecture. The proposed approach is expected to enhance the BEMS to address the uncertainty problem in order to process data in less time. Our experiment showed that the proposed approaches improved the accuracy by 7% compared to a typical BEMS with only one load forecasting technique, and had the lowest computation time when processing the smart meter data.

  18. Split energy level radiation detection

    International Nuclear Information System (INIS)

    Barnes, G.T.

    1986-01-01

    This patent describes an energy discriminating radiation detector comprising: (a) a first element comprising a first material of a kind which is preferentially responsive to penetrative radiation of a first energy range; (b) a second element comprising a second material different in kind from the first material and of a kind which is preferentially responsive to penetrative radiation of second energy range extending higher than the first energy range. The element is positioned to receive radiation which has penetrated through a portion of the first element; and (c) a filter of penetrative radiation interposed between the first and second elements

  19. A high rate clarifier for load levelling in sewerage systems.

    Science.gov (United States)

    Jago, R A; Davey, A; Li, H

    2003-01-01

    The combining of chemically assisted clarification with a proprietary physical separation technology has led to a high rate process for clarifying flocculated sewage and other waste streams. This hybrid physico-chemical system, known as the CDS Fine Solids Separation (FSS) System, was developed over a two year period within a sewage treatment plant environment. This paper summarises the results of a recent field trial of the system with a Victorian water authority which experiences heavy loading of sewers in a coastal town during holiday periods. The trial sought to evaluate the FSS as a tool for smoothing the load on the 11 km long sewer to the sewage treatment plant (STP). The FSS system could possibly enable the costly augmentation of the sewer to be deferred, particularly as the capacity of the existing sewer pipe is satisfactory for most of the year. Water quality parameters were determined for a range of flowrates and operational conditions over a two month period. Large reductions were achieved in TSS, TP, FC, turbidity and BOD5, with only minimal reductions in NH3 and TON. These results showed that the FSS could meet the authority's objectives for load levelling and would provide a 20-25% increase in effective sewer capacity. The data are also discussed in terms of possible use of the effluent from the FSS for water reuse applications.

  20. Grid Load Shifting and Performance Assessments of Residential Efficient Energy Technologies, a Case Study in Japan

    Directory of Open Access Journals (Sweden)

    Yanxue Li

    2018-06-01

    Full Text Available The increasing penetration of renewable energy decreases grid flexibility; thus, decentralized energy management or demand response are emerging as the main approaches to resolve this limitation and to provide flexibility of resources. This research investigates the performance of high energy efficiency appliances and grid-integrated distributed generators based on real monitored data from a social demonstration project. The analysis not only explores the potential cost savings and environmental benefits of high energy efficiency systems in the private sector, but also evaluates public grid load leveling potential from a bottom-up approach. This research provides a better understanding of the behavior of high decentralized efficient energy and includes detailed scenarios of monitored power generation and consumption in a social demonstration project. The scheduled heat pump effectively lifts valley load via transforming electricity to thermal energy, its daily electricity consumption varies from 4 kWh to 10 kWh and is concentrated in the early morning over the period of a year. Aggregated vehicle to home (V2H brings flexible resources to the grid, by discharging energy to cover the residential night peak load, with fuel cost savings attributed to 90% of profit. The potential for grid load leveling via integrating the power utility and consumer is examined using a bottom-up approach. Five hundred thousand contributions from scheduled electrical vehicles (EVs and fuel cells provide 5.0% of reliable peak power capacity at 20:00 in winter. The outcome illustrates the energy cost saving and carbon emission reduction scenarios of each of the proposed technologies. Relevant subsidies for heat pump water heater systems and cogeneration are essential customers due to the high initial capital investment. Optimal mixes in structure and coordinated control of high efficiency technologies enable customers to participate in grid load leveling in terms of

  1. Beam loading in high-energy storage rings

    International Nuclear Information System (INIS)

    Wilson, P.B.

    1974-06-01

    The analysis of beam loading in the RF systems of high-energy storage rings (for example, the PEP e/sup /minus//e/sup +/ ring) is complicated by the fact that the time, T/sub b/, between the passage of successive bunches is comparable to the cavity filling time, T/sub b/. In this paper, beam loading expressions are first summarized for the usual case in which T/sub b/ /much lt/ T/sub f/. The theory of phase oscillations in the heavily-beam-loaded case is considered, and the dependence of the synchrotron frequency and damping constant for the oscillations on beam current and cavity tuning is calculated. Expressions for beam loading are then derived which are valid for any value of the ratio T/sub b//T/sub f/. It is shown that, for the proposed PEP e/sup /minus//e/sup +/ ring parameters, the klystron power required is increased by about 3% over that calculated using the standard beam loading expressions. Finally, the analysis is extended to take into account the additional losses associated with the excitation of higher-order cavity modes. A rough numerical estimate is made of the loss enhancement to be expected for PEP RF system. It is concluded that this loss enhancement might be substantial unless appropriate measures are taken in the design and tuning of the accelerating structure

  2. Structural Loads Analysis for Wave Energy Converters: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    van Rij, Jennifer A [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Yu, Yi-Hsiang [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Guo, Yi [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-08-09

    This study explores and verifies the generalized body-modes method for evaluating the structural loads on a wave energy converter (WEC). Historically, WEC design methodologies have focused primarily on accurately evaluating hydrodynamic loads, while methodologies for evaluating structural loads have yet to be fully considered and incorporated into the WEC design process. As wave energy technologies continue to advance, however, it has become increasingly evident that an accurate evaluation of the structural loads will enable an optimized structural design, as well as the potential utilization of composites and flexible materials, and hence reduce WEC costs. Although there are many computational fluid dynamics, structural analyses and fluid-structure-interaction (FSI) codes available, the application of these codes is typically too computationally intensive to be practical in the early stages of the WEC design process. The generalized body-modes method, however, is a reduced order, linearized, frequency-domain FSI approach, performed in conjunction with the linear hydrodynamic analysis, with computation times that could realistically be incorporated into the WEC design process. The objective of this study is to verify the generalized body-modes approach in comparison to high-fidelity FSI simulations to accurately predict structural deflections and stress loads in a WEC. Two verification cases are considered, a free-floating barge and a fixed-bottom column. Details for both the generalized body-modes models and FSI models are first provided. Results for each of the models are then compared and discussed. Finally, based on the verification results obtained, future plans for incorporating the generalized body-modes method into the WEC simulation tool, WEC-Sim, and the overall WEC design process are discussed.

  3. Low cost electronic ultracapacitor interface technique to provide load leveling of a battery for pulsed load or motor traction drive applications

    Science.gov (United States)

    King, Robert Dean; DeDoncker, Rik Wivina Anna Adelson

    1998-01-01

    A battery load leveling arrangement for an electrically powered system in which battery loading is subject to intermittent high current loading utilizes a passive energy storage device and a diode connected in series with the storage device to conduct current from the storage device to the load when current demand forces a drop in battery voltage. A current limiting circuit is connected in parallel with the diode for recharging the passive energy storage device. The current limiting circuit functions to limit the average magnitude of recharge current supplied to the storage device. Various forms of current limiting circuits are disclosed, including a PTC resistor coupled in parallel with a fixed resistor. The current limit circuit may also include an SCR for switching regenerative braking current to the device when the system is connected to power an electric motor.

  4. Energy transfer from a superconducting magnet to an inductive load

    International Nuclear Information System (INIS)

    Onishi, Toshitada; Miura, Akinori.

    1977-01-01

    Experiments on energy transfer between two superconducting magnets have been carried out using an inductive energy transfer system similar to the flying capacitor system developed at the Karlsruhe Institute. In the present system the capacitor is grounded and diodes are used instead of thyristors, and a fraction of stored energy is transferred to the capacitor only when the relay connected in parallel to the magnet is switched off. The capacitor is expected to have no constraint in size, while in the flying capacitor system the capacitor is required to exceed a threshold size. Consequently it is possible to shorten the transfer time to some extent in comparison with the one in the flying capacitor system. Transfer experiments have been carried out using a storage magnet with inductance of 1.2H and a load of 0.41H. The capacitance is 200μF. It is possible to transfer 80.1% of the stored energy of 221 J into the load in less than about 0.35 seconds. (auth.)

  5. Absorption of short-pulse electromagnetic energy by a resistively loaded straight wire

    International Nuclear Information System (INIS)

    Miller, E.K.; Deadrick, F.J.; Landt, J.A.

    1975-01-01

    Absorption of short-pulse electromagnetic energy by a resistively loaded straight wire is examined. Energy collected by the wire, load energy, peak load currents, and peak load voltages are found for a wide range of parameters, with particular emphasis on nuclear electromagnetic pulse (EMP) phenomena. A series of time-sequenced plots is used to illustrate pulse propagation on wires when loads and wire ends are encountered

  6. A Smart Load Interface and Voltage Regulator for Electrostatic Vibration Energy Harvester

    Science.gov (United States)

    Bedier, Mohammed; Basset, Philippe; Galayko, Dimitri

    2016-11-01

    This paper presents a new implementation in ams 0.35μm HV technology of a complete energy management system for an electrostatic vibrational energy harvester (e-VEH). It is based on the Bennet's doubler architecture and includes a load voltage regulator (LVR) and a smart Load Interface (LI) that are self-controlled with internal voltages for maximum power point tracking (MMPT). The CMOS implementation makes use of an energy harvester that is capable of producing up to 1.8μW at harmonic excitation, given its internal voltage is kept within its optimum. An intermediate LI stage and its controller makes use of a high side switch with zero static power level shifter, and a low power hysteresis comparator. A full circuit level simulation with a VHDL-AMS model of the e-VEH presented was successfully achieved, indicating that the proposed load interface controller consumes less than 100nW average power. Moreover, a LVR regulates the buffer and discharge the harvested energy into a generic resistive load maintaining the voltage within a nominal value of 2 Volts.

  7. Atomic energy levels and Grotrian diagrams

    CERN Document Server

    Bashkin, Stanley

    1975-01-01

    Atomic Energy Levels and Grotrian Diagrams, Volume I: Hydrogen I - Phosphorus XV presents diagrams of various elements that show their energy level and electronic transitions. The book covers the first 15 elements according to their atomic number. The text will be of great use to researchers and practitioners of fields such as astrophysics that requires pictorial representation of the energy levels and electronic transitions of elements.

  8. Decrease of dynamic loads in mobile energy means

    Science.gov (United States)

    Polivaev, O. I.; Gorban, L. K.; Vorohobin, A. V.; Vedrinsky, O. S.

    2018-03-01

    The increase in the productivity of machine and tractor units is possible due to the increase in operating speeds, this leads to the emergence of increased dynamic loads in the system “engine-transmission-propulsion unit-soil”, which worsens the performance of machine-tractor aggregates. To reduce fluctuations in the “engine-transmission” system, special vibration dampers are used, which installed in close proximity to the engine and protect well the transmission from uneven engine operation; however, such dampers practically do not eliminate the oscillations of external loads. Reducing dynamic loads on the transmission and the mobile power engine (MPE) is an important issue directly related to improving the performance, reliability and durability of the tractor, as well as reducing the slippage of the drive wheels. In order to reduce effectively dynamic loads on the transmission and on the MPE, it is necessary to introduce resilient damping elements closer to the sources of oscillations, namely, to the driving wheels. At the same time, the elastic-damping element should provide accumulation of vibration energy caused by external influences and have a large energy capacity. The installation of an elastic-damping element in the final link of the tractor transmission ensures a reduction in the magnitude of external influences, thereby protecting the engine and transmission from large dynamic loads, and allows one to reduce the slippage of the propellers, which has a positive effect on the traction and energy characteristics of the tractor. Traction tests of the LTP-55 tractor on a concrete road showed that the use of an elasto-damping drive makes it possible to increase the maximum tractive power from 33.5 to 35.3 kW and to reduce the slipping of propellers by 12-30%, the specific fuel consumption by 6-10%. When driving on stubble, the use of an elastic-damping drive increases the maximum tractive power from 25 to 26 kW, reduces the skidding of propellers by

  9. Multifunctional Structures for High-Energy Lightweight Load-Bearing Storage

    Science.gov (United States)

    Loyselle, Patricia L.

    2018-01-01

    This is a pull-up banner of the Multifunctional Structures for High-Energy Lightweight Load-bearing Storage (M-SHELLS) technology that will be on display at the SciTech Conference in January 2018. Efforts in Multifunctional Structures for High Energy Load-Bearing Storage (M-Shells) are pushing the boundaries of development for hybrid electric propulsion for future commercial aeronautical transport. The M-Shells hybrid material would serve as the power/energy storage of the vehicle and provide structural integrity, freeing up usable volume and mass typically occupied by bulky batteries. The ultimate goal is to demonstrate a system-level mass savings with a multifunctional structure with energy storage.

  10. Wave Loadings Acting on an Innovative Breakwater for Energy Production

    DEFF Research Database (Denmark)

    Vicinanza, Diego; Ciardulli, F.; Buccino, M.

    2011-01-01

    The paper reports on 2D small scale experiments conducted to investigate wave loadings acting on a pilot project of device for the conversion of wave energy into electricity. The conversion concept is based on the overtopping principle and the structure is worldwide known with the acronym SSG....... The hydraulic model tests have been carried out at the LInC laboratory of the University of Naples Federico II using random waves. Results indicate wave overtopping is able to cause a sudden inversion of vertical force under wave crest, so that it is alternatively upward and downward directed over a short time...

  11. Supervisory Control of Loads and Energy Storage in Next-Generation Zero Energy Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Kung, Feitau [National Renewable Energy Lab. (NREL), Golden, CO (United States); Frank, Stephen [National Renewable Energy Lab. (NREL), Golden, CO (United States); Scheib, Jennifer [National Renewable Energy Lab. (NREL), Golden, CO (United States); Bernal Heredia, Willy [National Renewable Energy Lab. (NREL), Golden, CO (United States); Pless, Shanti [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-09-01

    A zero energy building (ZEB)—also known as a net zero energy or zero net energy building—is a building that exports as much renewable energy as the total energy it imports from other sources on an annual basis (DOE 2015). Large-scale and commercially viable ZEBs are now in the marketplace, and they are expected to become a larger share of the commercial building footprint as government and private sector policies continue to promote the development of buildings that produce more on-site energy than they use. However, the load profiles of ZEBs are currently perceived by electric utilities to be unfavorable and unpredictable. As shown in Figure ES-1, ZEB load profiles can have abrupt changes in magnitude, at times switching rapidly between exporting and importing electricity. This is a challenge for utilities, which are responsible for constantly balancing electricity supply and demand across the grid. Addressing these concerns will require new strategies and tools.

  12. National energy peak leveling program (NEPLP). Final report

    Energy Technology Data Exchange (ETDEWEB)

    None

    1977-12-01

    This multisectioned three-Volume report is responsive to the requirements of Contract E (04-3)-1152 to provide a detailed methodology, to include management, technology, and socio-economic aspects, of a voluntary community program of computer-assisted peak load leveling and energy conservation in commercial community facilities. The demonstration project established proof-of-concept in reducing the kW-demand peak by the unofficial goal of 10%, with concurrent kWh savings. This section of volume III contains appendixes of information on load shedding determination, analysis, socio-economic study, contractual cross references, and definitions.

  13. National energy peak leveling program (NEPLP). Final report

    Energy Technology Data Exchange (ETDEWEB)

    None

    1977-12-01

    This three-volume report is responsive to the requirements of Contract E (04-3)-1152 to provide a detailed methodology, to include management, technology, and socio-economic aspects, of a voluntary community program of computer-assisted peak load leveling and energy conservation in commercial community facilities. The demonstration project established proof-of-concept in reducing the kW-demand peak by the unofficial goal of 10%, with concurrent kWh savings. This section of the three volume report is a final report appendix with information on the National Energy Peak Leveling Program (NEPLP).

  14. An Energy Saving Green Plug Device for Nonlinear Loads

    Science.gov (United States)

    Bloul, Albe; Sharaf, Adel; El-Hawary, Mohamed

    2018-03-01

    The paper presents a low cost a FACTS Based flexible fuzzy logic based modulated/switched tuned arm filter and Green Plug compensation (SFC-GP) scheme for single-phase nonlinear loads ensuring both voltage stabilization and efficient energy utilization. The new Green Plug-Switched filter compensator SFC modulated LC-Filter PWM Switched Capacitive Compensation Devices is controlled using a fuzzy logic regulator to enhance power quality, improve power factor at the source and reduce switching transients and inrush current conditions as well harmonic contents in source current. The FACTS based SFC-GP Device is a member of family of Green Plug/Filters/Compensation Schemes used for efficient energy utilization, power quality enhancement and voltage/inrush current/soft starting control using a dynamic error driven fuzzy logic controller (FLC). The device with fuzzy logic controller is validated using the Matlab / Simulink Software Environment for enhanced power quality (PQ), improved power factor and reduced inrush currents. This is achieved using modulated PWM Switching of the Filter-Capacitive compensation scheme to cope with dynamic type nonlinear and inrush cyclical loads..

  15. Regional level approach for increasing energy efficiency

    International Nuclear Information System (INIS)

    Viholainen, Juha; Luoranen, Mika; Väisänen, Sanni; Niskanen, Antti; Horttanainen, Mika; Soukka, Risto

    2016-01-01

    Highlights: • Comprehensive snapshot of regional energy system for decision makers. • Connecting regional sustainability targets and energy planning. • Involving local players in energy planning. - Abstract: Actions for increasing the renewable share in the energy supply and improving both production and end-use energy efficiency are often built into the regional level sustainability targets. Because of this, many local stakeholders such as local governments, energy producers and distributors, industry, and public and private sector operators require information on the current state and development aspects of the regional energy efficiency. The drawback is that an overall view on the focal energy system operators, their energy interests, and future energy service needs in the region is often not available for the stakeholders. To support the local energy planning and management of the regional energy services, an approach for increasing the regional energy efficiency is being introduced. The presented approach can be seen as a solid framework for gathering the required data for energy efficiency analysis and also evaluating the energy system development, planned improvement actions, and the required energy services at the region. This study defines the theoretical structure of the energy efficiency approach and the required steps for revealing such energy system improvement actions that support the regional energy plan. To demonstrate the use of the approach, a case study of a Finnish small-town of Lohja is presented. In the case example, possible actions linked to the regional energy targets were evaluated with energy efficiency analysis. The results of the case example are system specific, but the conducted study can be seen as a justified example of generating easily attainable and transparent information on the impacts of different improvement actions on the regional energy system.

  16. Optimum community energy storage system for demand load shifting

    International Nuclear Information System (INIS)

    Parra, David; Norman, Stuart A.; Walker, Gavin S.; Gillott, Mark

    2016-01-01

    Highlights: • PbA-acid and lithium-ion batteries are optimised up to a 100-home community. • A 4-period real-time pricing and Economy 7 (2-period time-of-use) are compared. • Li-ion batteries perform worse with Economy 7 for small communities and vice versa. • The community approach reduced the levelised cost by 56% compared to a single home. • Heat pumps reduced the levelised cost and increased the profitability of batteries. - Abstract: Community energy storage (CES) is becoming an attractive technological option to facilitate the use of distributed renewable energy generation, manage demand loads and decarbonise the residential sector. There is strong interest in understanding the techno-economic benefits of using CES systems, which energy storage technology is more suitable and the optimum CES size. In this study, the performance including equivalent full cycles and round trip efficiency of lead-acid (PbA) and lithium-ion (Li-ion) batteries performing demand load shifting are quantified as a function of the size of the community using simulation-based optimisation. Two different retail tariffs are compared: a time-of-use tariff (Economy 7) and a real-time-pricing tariff including four periods based on the electricity prices on the wholesale market. Additionally, the economic benefits are quantified when projected to two different years: 2020 and a hypothetical zero carbon year. The findings indicate that the optimum PbA capacity was approximately twice the optimum Li-ion capacity in the case of the real-time-pricing tariff and around 1.6 times for Economy 7 for any community size except a single home. The levelised cost followed a negative logarithmic trend while the internal rate of return followed a positive logarithmic trend as a function of the size of the community. PbA technology reduced the levelised cost down to 0.14 £/kW h when projected to the year 2020 for the retail tariff Economy 7. CES systems were sized according to the demand load and

  17. State-Level Benefits of Energy Efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Tonn, Bruce Edward [ORNL

    2007-02-01

    This report describes benefits attributable to state-level energy efficiency programs. Nationwide, state-level energy efficiency programs have targeted all sectors of the economy and have employed a wide range of methods to promote energy efficiency. Standard residential and industrial programs typically identify between 20 to 30% energy savings in homes and plants, respectively. Over a 20 year period of time, an average state that aggressively pursues even a limited array of energy efficiency programs can potentially reduce total state energy use by as much as 20%. Benefit-cost ratios of effective energy efficiency programs typically exceed 3 to 1 and are much higher when non-energy and macroeconomic benefits are included. Indeed, energy efficiency and associated programs and investments can create significant numbers of new jobs and enhance state tax revenues. Several states have incorporated energy efficiency into their economic development programs. It should also be noted that increasing amounts of venture capital are being invested in the energy sector in general and in specific technologies like solar power in particular. Well-designed energy efficiency programs can be expected to help overcome numerous barriers to the market penetration of energy efficient technologies and accelerate the market penetration of the technologies.

  18. State-level benefits of energy efficiency

    International Nuclear Information System (INIS)

    Tonn, Bruce; Peretz, Jean H.

    2007-01-01

    This paper describes benefits attributable to state-level energy efficiency programs. Nationwide, state-level energy efficiency programs have targeted all sectors of the economy and have employed a wide range of methods to promote energy efficiency. Standard residential and industrial programs typically identify between 20% and 30% energy savings in homes and plants, respectively. Over a 20-year period of time, an average state that aggressively pursues even a limited array of energy efficiency programs can potentially reduce total state energy use by as much as 20%. Well-designed energy efficiency programs can be expected to help overcome numerous barriers to the market penetration of energy efficient technologies and accelerate the market penetration of the technologies. Energy efficiency programs are cost-effective; typical benefit-cost ratios exceed 3:1 and are much higher when non-energy and macroeconomic benefits are included. Indeed, energy efficiency and associated programs and investments can create significant numbers of new jobs and enhance state tax revenues. Several states have incorporated energy efficiency into their economic development programs. It should also be noted that increasing amounts of venture capital are being invested in the energy sector in general and in specific technologies like solar power in particular. (author)

  19. Managing peak loads in energy grids: Comparative economic analysis

    International Nuclear Information System (INIS)

    Zhuk, A.; Zeigarnik, Yu.; Buzoverov, E.; Sheindlin, A.

    2016-01-01

    One of the key issues in modern energy technology is managing the imbalance between the generated power and the load, particularly during times of peak demand. The increasing use of renewable energy sources makes this problem even more acute. Various existing technologies, including stationary battery energy storage systems (BESS), can be employed to provide additional power during peak demand times. In the future, integration of on-board batteries of the growing fleet of electric vehicles (EV) and plug-in hybrid electric vehicles (PHEV) into the grid can provide power during peak demand hours (vehicle-to-grid, or V2G technology). This work provides cost estimates of managing peak energy demands using traditional technologies, such as maneuverable power plants, conventional hydroelectric, pumped storage plants and peaker generators, as well as BESS and V2G technologies. The derived estimates provide both per kWh and kW year of energy supplied to the grid. The analysis demonstrates that the use of battery storage is economically justified for short peak demand periods of <1 h. For longer durations, the most suitable technology remains the use of maneuverable steam gas power plants, gas turbine,reciprocating gas engine peaker generators, conventional hydroelectric, pumped storage plants. - Highlights: • Cost of managing peak energy demand employing different technologies are estimated. • Traditional technologies, stationary battery storage and V2G are compared. • Battery storage is economically justified for peak demand periods of <1 h. • V2G appears to have better efficiency than stationary battery storage in low voltage power grids.

  20. Energy Levels of Hydrogen and Deuterium

    Science.gov (United States)

    SRD 142 NIST Energy Levels of Hydrogen and Deuterium (Web, free access)   This database provides theoretical values of energy levels of hydrogen and deuterium for principle quantum numbers n = 1 to 200 and all allowed orbital angular momenta l and total angular momenta j. The values are based on current knowledge of the revelant theoretical contributions including relativistic, quantum electrodynamic, recoil, and nuclear size effects.

  1. Test plan: Effects of phase separation on waste loading for high level waste glasses

    International Nuclear Information System (INIS)

    Jantzen, C.M.

    2000-01-01

    As part of the Tanks Focus Area's (TFA) effort to increase waste loading for high-level waste (HLW) vitrification at various facilities in the Department of Energy (DOE) complex, the occurrence of phase separation in waste glasses spanning the Savannah River Site (SRS) and Idaho National Engineering and Environmental Laboratory (INEEL) composition ranges were studied during FY99. The type, extent, and impact of phase separation on glass durability for a series of HLW glasses, e.g., SRS-type and INEEL-type, were examined

  2. Scheduling algorithms for saving energy and balancing load

    Energy Technology Data Exchange (ETDEWEB)

    Antoniadis, Antonios

    2012-08-03

    In this thesis we study problems of scheduling tasks in computing environments. We consider both the modern objective function of minimizing energy consumption, and the classical objective of balancing load across machines. We first investigate offline deadline-based scheduling in the setting of a single variable-speed processor that is equipped with a sleep state. The objective is that of minimizing the total energy consumption. Apart from settling the complexity of the problem by showing its NP-hardness, we provide a lower bound of 2 for general convex power functions, and a particular natural class of schedules called s{sub crit}-schedules. We also present an algorithmic framework for designing good approximation algorithms. For general convex power functions our framework improves the best known approximation-factor from 2 to 4/3. This factor can be reduced even further to 137/117 for a specific well-motivated class of power functions. Furthermore, we give tight bounds to show that our framework returns optimal s{sub crit}-schedules for the two aforementioned power-function classes. We then focus on the multiprocessor setting where each processor has the ability to vary its speed. Job migration is allowed, and we again consider classical deadline-based scheduling with the objective of energy minimization. We first study the offline problem and show that optimal schedules can be computed efficiently in polynomial time for any convex and non-decreasing power function. Our algorithm relies on repeated maximum flow computations. Regarding the online problem and power functions P(s) = s{sup {alpha}}, where s is the processor speed and {alpha} > 1 a constant, we extend the two well-known single-processor algorithms Optimal Available and Average Rate. We prove that Optimal Available is {alpha}{sup {alpha}}-competitive as in the single-processor case. For Average Rate we show a competitive factor of (2{alpha}){sup {alpha}}/2 + 1, i.e., compared to the single

  3. High Level Waste (HLW) Processing Experience with Increased Waste Loading

    International Nuclear Information System (INIS)

    JANTZEN, CAROL

    2004-01-01

    The Defense Waste Processing Facility (DWPF) Engineering requested characterization of glass samples that were taken after the second melter had been operational for about 5 months. After the new melter had been installed, the waste loading had been increased to about 38 weight percentage after a new quasicrystalline liquidus model had been implemented. The DWPF had also switched from processing with refractory Frit 200 to a more fluid Frit 320. The samples were taken after DWPF observed very rapid buildup of deposits in the upper pour spout bore and on the pour spout insert while processing the high waste loading feedstock. These samples were evaluated using various analytical techniques to determine the cause of the crystallization. The pour stream sample was homogeneous, amorphous, and representative of the feed batch from which it was derived. Chemical analysis of the pour stream sample indicated that a waste loading of 38.5 weight per cent had been achieved. The data analysis indicated that surface crystallization, induced by temperature and oxygen fugacity gradients in the pour spout, caused surface crystallization to occur in the spout and on the insert at the higher waste loadings even though there was no crystallization in the pour stream

  4. Load levelling measures being tackled by shikoku Electric Power Co. Inc.; Shikoku Denryoku Kabushi Kaisha no fuka heijunka eno torikumi

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-11-01

    For the electric power companies, the activity of pushing forward the load levelling contributes greatly to the curtailment of cost by means of effective formation and utilization of facilities. It is planned to take up more positive activities with a target of 3% improvement in the load factor in ten years. Concrete measures for further promotion of load levelling are the diversity of the rate menu of appraising the load levelling effort of the customers and the promotion of the spread of equipment and systems relating to load levelling such as electric water heating apparatuses and thermal energy storage air conditioning systems. The rate system has been reviewed taking the opportunity of rate revision made in January, 1996. Particularly, further load shift to midnight time zone is expected as a result of better rate incentive for customers which is brought about by large reduction of the rate level due to the cost reduction effect accompanying the improvement in atomic power generation ratio. Outlines are given on the fields relating to general households, business, dwellings, buildings, and industry. 3 figs., 1 tab.

  5. Revised energy levels of singly ionized lanthanum

    Science.gov (United States)

    Güzelçimen, Feyza; Tonka, Mehdi; Uddin, Zaheer; Bhatti, Naveed Anjum; Windholz, Laurentius; Kröger, Sophie; Başar, Gönül

    2018-05-01

    Based on the experimental wavenumbers of 344 spectral lines from calibrated Fourier transform (FT) spectra as well as wavenumbers of 81 lines from the wavelength tables from literature, the energy of 115 fine structure levels of singly ionized lanthanum has been revised by weighted global fits. The classifications of the lines are provided by numerous previous investigations of lanthanum by different spectroscopic methods and authors. For the high accurate determination of the center of gravity wavenumbers from the experimental spectrum, the hyperfine constants of the involved levels have been taken into account, if possible. For the 94 levels with known hyperfine constants the accuracy of energy values is better than 0.01 cm-1. For 34 levels the magnetic dipole hyperfine constants A have been determined from FT spectra as part of this work. For four of these 34 levels even electric quadrupole hyperfine constants B could be estimated. For levels, which have experimentally unknown hyperfine constants and which are connected only by lines not found in the FT spectra but taken from literature, the uncertainties of energy values are about a factor of 10 higher. A list of all revised level energies together with a compilation of hyperfine structure data is given as well as a list of all lines used.

  6. Load leveling total system. Part 2. Development of load leveling logic for residential customer; Fuka heijunka total system. 2. Kateiyo juyoka wo taisho to shita heijunka ronri no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Asari, M.; Nanahara, T. [Central Research Institute of Electric Power Industry, Tokyo (Japan)

    1995-05-01

    It is essential, in order to meet steadily increasing demands for electrical power, to develop techniques for effective utilization of energy and load leveling. Described herein is development, by the aid of linear programming, of logic for daily management of charge/discharge of load conditioners and reverse power flow, for predicted loads and patterns of power generated by photovoltaic cells installed at individual customers. It is aimed at minimizing power rate and leveling of load at distribution systems. Predicted loads, outputs by photovoltaic cell units and different power rates by time zone for the next day are inputted, to determine the charge/discharge schedules and power supply/reverse flow patterns for that day, in order to minimize power rates and level loads at higher hierarchical levels. The logic-aided daily simulation for various districts confirms the operational patterns that realize improved utilization of pole-mounted transformers while reducing costs at customers, and effects of prediction errors. 4 refs., 14 figs.

  7. Occupation number dependence of molecular energy levels

    International Nuclear Information System (INIS)

    Giambiagi, M.S. de; Giambiagi, M.; Ferreira, R.

    1977-08-01

    The Roothaan expression for the energy of a closed-shell molecular system is generalized in order to apply to open shells. A continuous variation from 0 to 2 is supposed for each level's occupation number, extending to this range tbe correction due to the spurious repulsion appearing in the half-electron method. The characteristic equations of the Xα method are applied to the energy expressions. The one level case is discussed in detail. Ionic and excited states of the 1,3 transbutadiene π system are analyzed

  8. Impurity energy level in the Haldane gap

    International Nuclear Information System (INIS)

    Wang Wei; Lu Yu

    1995-11-01

    An impurity bond J' in a periodic 1D antiferromagnetic spin 1 chain with exchange J is considered. Using the numerical density matrix renormalization group method, we find an impurity energy level in the Haldane gap, corresponding to a bound state near the impurity bond. When J' J. The impurity level appears only when the deviation dev = (J'- J)/J' is greater than B c , which is close to 0.3 in our calculation. (author). 15 refs, 4 figs

  9. On expectation values for nuclear energy levels

    International Nuclear Information System (INIS)

    De Wet, J.A.

    1978-01-01

    The nuclear model is built up by constructing measured states, including the ground state, from the vacuum state. All states are, however, not accessible from the ground state so that selection rules may be found which at the same time impose even more stringent conditions on the labelling of energy levels. These are the subject of this paper

  10. Tapping the energy storage potential in electric loads to deliver load following and regulation, with application to wind energy

    International Nuclear Information System (INIS)

    Callaway, Duncan S.

    2009-01-01

    This paper develops new methods to model and control the aggregated power demand from a population of thermostatically controlled loads, with the goal of delivering services such as regulation and load following. Previous work on direct load control focuses primarily on peak load shaving by directly interrupting power to loads. In contrast, the emphasis of this paper is on controlling loads to produce relatively short time scale responses (hourly to sub-hourly), and the control signal is applied by manipulation of temperature set points, possibly via programmable communicating thermostats or advanced metering infrastructure. To this end, the methods developed here leverage the existence of system diversity and use physically-based load models to inform the development of a new theoretical model that accurately predicts - even when the system is not in equilibrium - changes in load resulting from changes in thermostat temperature set points. Insight into the transient dynamics that result from set point changes is developed by deriving a new exact solution to a well-known hybrid state aggregated load model. The eigenvalues of the solution, which depend only on the thermal time constant of the loads under control, are shown to have a strong effect on the accuracy of the model. The paper also shows that load heterogeneity - generally something that must be assumed away in direct load control models - actually has a positive effect on model accuracy. System identification techniques are brought to bear on the problem, and it is shown that identified models perform only marginally better than the theoretical model. The paper concludes by deriving a minimum variance control law, and demonstrates its effectiveness in simulations wherein a population of loads is made to follow the output of a wind plant with very small changes in the nominal thermostat temperature set points.

  11. Spectrum and energy levels of Y VI

    International Nuclear Information System (INIS)

    Persson, W.; Reader, J.

    1986-01-01

    The spectrum of the five-times-ionized yttrium atom (Y VI), excited in a sliding-spark discharge, was studied in the 160--2500 A-circle range. About 900 Y VI lines were classified as transitions between 101 odd and 69 even energy levels.The energy-level system established includes almost all levels of the 4s 2 4p 4 , 4s4p 5 , 4s 2 4p 3 4d, 5d, 5s, 6s, and 5p configurations and a number of levels of the 7s, 4f, and 4s4p 4 4d configurations. The observed level system has been theoretically interpreted by means of Hartree--Fock calculations and least-squares parametric fits. Strong configuration mixings are found between the 4s4p 5 and 4s 2 4p 3 4d configurations, between the 4s 2 4p 3 5p and 4s4p 4 4d configurations, and between the 4s 2 4p 3 4f and 4s4p 4 4d configurations. From the optimized energy-level values, a system of Ritz-type wavelength standards with accuracies varying from 0.0003 to 0.003 A-circle in the range 179--500 A-circle has been determined. The ionization energy as determined from 4s 2 4p 3 ns levels (n = 5-7) is 737 110 +- 200 cm/sup -1/ (91.390 +- 0.025 eV)

  12. National energy peak leveling program (NEPLP). Final report

    Energy Technology Data Exchange (ETDEWEB)

    None

    1977-12-01

    This three-volume report is responsive to the requirements of contract E (04-3)-1152 to provide a detailed methodology, to include management, technology, and socio-economic aspects, of a voluntary community program for computer-assisted peak load leveling and energy conservation in commercial community facilities. The demonstration project established proof-of-concept in reducing the kW-demand peak by the unofficial goal of 10%, with concurrent kWh savings. The report consists of the following three volumes: Volume I: management overview; Volume II: methodology and technology; and Volume III; appendices.

  13. Frontiers of controlling energy levels at interfaces

    Science.gov (United States)

    Koch, Norbert

    The alignment of electron energy levels at interfaces between semiconductors, dielectrics, and electrodes determines the function and efficiency of all electronic and optoelectronic devices. Reliable guidelines for predicting the level alignment for a given material combination and methods to adjust the intrinsic energy landscape are needed to enable efficient engineering approaches. These are sufficiently understood for established electronic materials, e.g., Si, but for the increasing number of emerging materials, e.g., organic and 2D semiconductors, perovskites, this is work in progress. The intrinsic level alignment and the underlying mechanisms at interfaces between organic and inorganic semiconductors are discussed first. Next, methods to alter the level alignment are introduced, which all base on proper charge density rearrangement at a heterojunction. As interface modification agents we use molecular electron acceptors and donors, as well as molecular photochromic switches that add a dynamic aspect and allow device multifunctionality. For 2D semiconductors surface transfer doping with molecular acceptors/donors transpires as viable method to locally tune the Fermi-level position in the energy gap. The fundamental electronic properties of a prototypical 1D interface between intrinsic and p-doped 2D semiconductor regions are derived from local (scanning probe) and area-averaged (photoemission) spectroscopy experiments. Future research opportunities for attaining unsurpassed interface control through charge density management are discussed.

  14. The Load Level of Modern Wind Turbines according to IEC 61400-1

    International Nuclear Information System (INIS)

    Freudenreich, K; Argyriadis, K

    2007-01-01

    The paper describes some effects on the load level of state-of-the art multi megawatt wind turbines introduced by the new edition of the standard IEC 61400-1:2005 W ind Turbines - Part 1: Design requirements . Compared to the previous edition, especially the extreme load determination has been modified by applying stochastic and statistical analyses. Within this paper the effect on the overall load level of wind turbines is demonstrated and occurring problems are discussed. Load simulations have been carried out for four state-of-the-art multi-megawatt wind turbines of different design concepts and from different manufacturers. The blade root bending moments and tip deflection have been determined by applying different extrapolation methods. Advantages and disadvantages of these methods and tail fittings for different load components and wind turbine technologies are discussed and interpreted. Further on, the application of the extreme turbulence model is demonstrated. The dependence of the load level on the turbulence intensity and control system, as well as the interaction with extrapolated loads is discussed and limitations outlined. The obtained load level is compared to the overall load level of the turbines according to the previous edition of the standard, IEC 61400-1:1999

  15. Upper Limb Muscle and Brain Activity in Light Assembly Task on Different Load Levels

    Science.gov (United States)

    Zadry, Hilma Raimona; Dawal, Siti Zawiah Md.; Taha, Zahari

    2010-10-01

    A study was conducted to investigate the effect of load on upper limb muscles and brain activities in light assembly task. The task was conducted at two levels of load (Low and high). Surface electromyography (EMG) was used to measure upper limb muscle activities of twenty subjects. Electroencephalography (EEG) was simultaneously recorded with EMG to record brain activities from Fz, Pz, O1 and O2 channels. The EMG Mean Power Frequency (MPF) of the right brachioradialis and the left upper trapezius activities were higher on the high-load task compared to low-load task. The EMG MPF values also decrease as time increases, that reflects muscle fatigue. Mean power of the EEG alpha bands for the Fz-Pz channels were found to be higher on the high-load task compared to low-load task, while for the O1-O2 channels, they were higher on the low-load task than on the high-load task. These results indicated that the load levels effect the upper limb muscle and brain activities. The high-load task will increase muscle activities on the right brachioradialis and the left upper tapezius muscles, and will increase the awareness and motivation of the subjects. Whilst the low-load task can generate drowsiness earlier. It signified that the longer the time and the more heavy of the task, the subjects will be more fatigue physically and mentally.

  16. Impacts of Commercial Building Controls on Energy Savings and Peak Load Reduction

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez, Nicholas E.P. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Katipamula, Srinivas [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Wang, Weimin [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Xie, YuLong [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zhao, Mingjie [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Corbin, Charles D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2017-05-30

    Commercial buildings in the United States use about 18 Quadrillion British thermal units (Quads) of primary energy annually . Studies have shown that as much as 30% of building energy consumption can be avoided by using more accurate sensing, using existing controls better, and deploying advanced controls; hence, the motivation for the work described in this report. Studies also have shown that 10% to 20% of the commercial building peak load can be temporarily managed/curtailed to provide grid services. Although many studies have indicated significant potential for reducing the energy consumption in commercial buildings, very few have documented the actual savings. The studies that did so only provided savings at the whole building level, which makes it difficult to assess the savings potential of each individual measure deployed.

  17. Peak load shifting control using different cold thermal energy storage facilities in commercial buildings: A review

    International Nuclear Information System (INIS)

    Sun, Yongjun; Wang, Shengwei; Xiao, Fu; Gao, Diance

    2013-01-01

    Highlights: • Little study reviews the load shifting control using different facilities. • This study reviews load shifting control using building thermal mass. • This study reviews load shifting control using thermal energy storage systems. • This study reviews load shifting control using phase change material. • Efforts for developing more applicable load shifting control are addressed. - Abstract: For decades, load shifting control, one of most effective peak demand management methods, has attracted increasing attentions from both researchers and engineers. Different load shifting control strategies have been developed when diverse cold thermal energy storage facilities are used in commercial buildings. The facilities include building thermal mass (BTM), thermal energy storage system (TES) and phase change material (PCM). Little study has systematically reviewed these load shifting control strategies and therefore this study presents a comprehensive review of peak load shifting control strategies using these thermal energy storage facilities in commercial buildings. The research and applications of the load shifting control strategies are presented and discussed. The further efforts needed for developing more applicable load shifting control strategies using the facilities are also addressed

  18. A coupled nuclear reactor thermal energy storage system for enhanced load following operation

    International Nuclear Information System (INIS)

    Alameri, Saeed A.; King, Jeffrey C.

    2013-01-01

    Nuclear power plants operate most economically at a constant power level, providing base load electric power. In an energy grid containing a high fraction of renewable power sources, nuclear reactors may be subject to significantly variable power demands. These variable power demands can negatively impact the effective capacity factor of the reactor and result in severe economic penalties. Coupling a nuclear reactor to a large thermal energy storage block will allow the reactor to better respond to variable power demands. In the system described in this paper, a Prismatic core Advanced High Temperature Reactor supplies constant power to a lithium chloride molten salt thermal energy storage block that provides thermal power as needed to a closed Brayton cycle energy conversion system. During normal operation, the thermal energy storage block stores thermal energy during the night for use in the times of peak demand during the day. In this case, the nuclear reactor stays at a constant thermal power level. After a loss of forced circulation, the reactor reaches a shut down state in less than half an hour and the average fuel, graphite and coolant temperatures remain well within the design limits over the duration of the transient, demonstrating the inherent safety of the coupled system. (author)

  19. Indirect Load Control for Energy Storage Systems Using Incentive Pricing under Time-of-Use Tariff

    Directory of Open Access Journals (Sweden)

    Mu-Gu Jeong

    2016-07-01

    Full Text Available Indirect load control (ILC is a method by which the customer determines load reduction of electricity by using a price signal. One of the ILCs is a time-of-use (TOU tariff, which is the most commonly used time-varying retail pricing. Under the TOU tariff, the customer can reduce the energy cost through an energy storage system (ESS. However, because this tariff is fixed for several months, the ESS operation does not truly reflect the wholesale market price, which could widely fluctuate. To overcome this limitation, this paper proposes an incentive pricing method in which the load-serving entity (LSE gives the incentive pricing signal to the customers with ESSs. Because the ESS charging schedule is determined by the customer through ILC, a bilevel optimization problem that includes the customer optimization problem is utilized to determine the incentive pricing signal. Further, the bilevel optimization problem is reformulated into a one-level problem to be solved by an interior point method. In the proposed incentive scheme: (1 the social welfare increases and (2 the increased social welfare can be equitably divided between the LSE and the customer; and (3 the proposed incentive scheme leads the customer to voluntarily follow the pricing signal.

  20. Ice thermal storage air conditioning system for electric load leveling; Denryoku heijunka to hyochikunetsu system

    Energy Technology Data Exchange (ETDEWEB)

    Shigenaga, Y. [Daikin Industries Ltd., Osaka (Japan)

    1998-08-15

    Thermal storage air conditioning system is the one to use energy stored into thermal storing materials by using night electric power and to operate effective air conditioning. Therefore, as load can be treated by the stored energy, volume of the apparatus can be reduced. And, by reduction of the consumed power at day time, it can contribute to leveling of electric power demand. In general, there are two types in the thermal storage method: one is a method to store as thermal energy, and the other is that to store as chemical energy. For conditions required for the storing materials, important elements on their actual uses are not only physical properties such as large thermal storage per unit and easy thermal in- and out-puts, but also safety, long-term reliability, and easy receiving and economics containing future. The ice thermal storage air conditioning system is classified at the viewpoint of type of ice, kind of thermal storing medium, melting method on using cooling and heating, kinds of thermal medium on cooling and heating. 3 refs., 5 figs., 2 tabs.

  1. Development of Zinc/Bromine Batteries for Load-Leveling Applications: Phase 1 Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Eidler, Phillip

    1999-07-01

    The Zinc/Bromine Load-Leveling Battery Development contract (No. 40-8965) was partitioned at the outset into two phases of equal length. Phase 1 started in September 1990 and continued through December 1991. In Phase 1, zinc/bromine battery technology was to be advanced to the point that it would be clear that the technology was viable and would be an appropriate choice for electric utilities wishing to establish stationary energy-storage facilities. Criteria were established that addressed most of the concerns that had been observed in the previous development efforts. The performances of 8-cell and 100-cell laboratory batteries demonstrated that the criteria were met or exceeded. In Phase 2, 100-kWh batteries will be built and demonstrated, and a conceptual design for a load-leveling plant will be presented. At the same time, work will continue to identify improved assembly techniques and operating conditions. This report details the results of the efforts carried out in Phase 1. The highlights are: (1) Four 1-kWh stacks achieved over 100 cycles, One l-kWh stack achieved over 200 cycles, One 1-kWh stack achieved over 300 cycles; (2) Less than 10% degradation in performance occurred in the four stacks that achieved over 100 cycles; (3) The battery used for the zinc loading investigation exhibited virtually no loss in performance for loadings up to 130 mAh/cm{sup 2}; (4) Charge-current densities of 50 ma/cm{sup 2} have been achieved in minicells; (5) Fourteen consecutive no-strip cycles have been conducted on the stack with 300+ cycles; (6) A mass and energy balance spreadsheet that describes battery operation was completed; (7) Materials research has continued to provide improvements in the electrode, activation layer, and separator; and (8) A battery made of two 50-cell stacks (15 kWh) was produced and delivered to Sandia National Laboratories (SNL) for testing. The most critical development was the ability to assemble a battery stack that remained leak free. The

  2. Wire rope superconducting cable for diurnal load leveling SMES

    International Nuclear Information System (INIS)

    Costello, G.A.

    1980-01-01

    The design of a wire rope cable for a superconducting magnetic energy storage (SMES) unit is discussed. The superconducting wires in the rope permit the passage of large currents in the relatively small conductors of the windings and hence cause large electromagnetic forces to act on the rope. The diameter of the rope, from a strength point of view, can be considerably reduced by supporting the rope at various points along its length

  3. On Low Energy Levels in 185W

    International Nuclear Information System (INIS)

    Malmskog, S.G.; Hoejeberg, M.; Berg, V.

    1969-02-01

    Gamma ray spectra in the decay of 185 Ta and 185m W have been studied with Ge (Li) detectors. The 185m W isomeric transition at 131.6 keV is shown to be of E3 multipolarity. A level scheme of 185 W is proposed with the following energy levels (energies in keV, spin and K quantum numbers in brackets): 0 (3/2 - 3/2), 23.5 (1/2 - 1/2), 65.9 (5/2 - 3/2), 93.5 (3/2 - 1/2) (uncertain), 173.9 (7/2 - 3/2), 188.1 (5/2 - 1/2), 197.5 (11/2 + 11/2) , 243.5 (7/2 - 7/2), and 390.8 (9/2 - 7/2)

  4. Comparison of energy performance requirements levels

    DEFF Research Database (Denmark)

    Spiekman, Marleen; Thomsen, Kirsten Engelund; Rose, Jørgen

    This summary report provides a synthesis of the work within the EU SAVE project ASIEPI on developing a method to compare the energy performance (EP) requirement levels among the countries of Europe. Comparing EP requirement levels constitutes a major challenge. From the comparison of for instance...... the present Dutch requirement level (EPC) of 0,8 with the present Flemish level of E80, it can easily be seen that direct comparison is not possible. The conclusions and recommendations of the study are presented in part A. These constitute the most important result of the project. Part B gives an overview...... of all other project material related to that topic, which allows to easily identify the most pertinent information. Part C lists the project partners and sponsors....

  5. Thermal to Electric Energy Conversion for Cyclic Heat Loads

    Science.gov (United States)

    Whitehead, Benjamin E.

    Today, we find cyclic heat loads almost everywhere. When we drive our cars, the engines heat up while we are driving and cool while parked. Processors heat while the computer is in use at the office and cool when idle at night. The sun heats the earth during the day and the earth radiates that heat into space at night. With modern technology, we have access to a number of methods to take that heat and convert it into electricity, but, before selecting one, we need to identify the parameters that inform decision making. The majority of the parameters for most systems include duty cycle, total cost, weight, size, thermal efficiency, and electrical efficiency. However, the importance of each of these will depend on the application. Size and weight take priority in a handheld device, while efficiency dominates in a power plant, and duty cycle is likely to dominate in highly demanding heat pump applications. Over the past decade, developments in semiconductor technology has led to the creation of the thermoelectric generator. With no moving parts and a nearly endlessly scalable nature, these generators present interesting opportunities for taking advantage of any source of waste heat. However, these generators are typically only capable of 5-8% efficiency from conversion of thermal to electric energy. [1]. Similarly, advancements in photovoltaic cells has led to the development of thermophotovoltaics. By heating an emitter to a temperature so it radiates light, a thermophotovoltaic cell then converts that light into electricity. By selecting materials that emit light in the optimal ranges of the appropriate photovoltaic cells, thermophotovoltaic systems can potentially exceed the current maximum of 10% efficiency. [2]. By pressurizing certain metal powders with hydrogen, hydrogen can be bound to the metal, creating a metal hydride, from which hydrogen can be later re-extracted under the correct pressure and temperature conditions. Since this hydriding reaction is

  6. HBsAg level and hepatitis B viral load correlation with focus on pregnancy

    Science.gov (United States)

    Belopolskaya, Maria; Avrutin, Viktor; Firsov, Sergey; Yakovlev, Alexey

    2015-01-01

    Background Viral load measurement is necessary to estimate mother-to-child transmission risk for women with chronic hepatitis B (CHB), however, it is expensive. The present study aimed to investigate the relationship between HBsAg and hepatitis B virus (HBV) DNA levels, and to determine potential applications of HBsAg level monitoring for estimating viral load. Methods 85 patients with CHB (31 pregnant women, 26 non-pregnant women, 28 men) were included in the study. HBV DNA level was measured by real-time PCR, and HBsAg level by chemiluminescent immunoassay method. Dependency between viral load and HBsAg level was determined by Spearman correlation coefficient ρ. Results The correlation between HBsAg and HBV DNA levels was significant for all patients [ρ=0.3762 (P<0.0005; n=85)]. In the group of pregnant women, a low (unmeasurable) HBV DNA level led to a decrease in the Spearman coefficient ρ. In almost all cases a low level of the HBsAg corresponded to a low HBV DNA level. Only 2 patients had a low level of HBsAg and a relatively high viral load. By contrast, a high HBsAg level was observed in patients both with high and low viral load. Conclusions Correlation between HBsAg and HBV DNA levels is significant. In most cases, a low level of HBsAg indicates a low HBV DNA level, whereas a high HBsAg level does not always correspond to a high viral load. The measurement of HBV DNA level is necessary for pregnant women with a high HBsAg level. PMID:26127004

  7. Energy level diagrams for black hole orbits

    Science.gov (United States)

    Levin, Janna

    2009-12-01

    A spinning black hole with a much smaller black hole companion forms a fundamental gravitational system, like a colossal classical analog to an atom. In an appealing if imperfect analogy with atomic physics, this gravitational atom can be understood through a discrete spectrum of periodic orbits. Exploiting a correspondence between the set of periodic orbits and the set of rational numbers, we are able to construct periodic tables of orbits and energy level diagrams of the accessible states around black holes. We also present a closed-form expression for the rational q, thereby quantifying zoom-whirl behavior in terms of spin, energy and angular momentum. The black hole atom is not just a theoretical construct, but corresponds to extant astrophysical systems detectable by future gravitational wave observatories.

  8. Energy level diagrams for black hole orbits

    International Nuclear Information System (INIS)

    Levin, Janna

    2009-01-01

    A spinning black hole with a much smaller black hole companion forms a fundamental gravitational system, like a colossal classical analog to an atom. In an appealing if imperfect analogy with atomic physics, this gravitational atom can be understood through a discrete spectrum of periodic orbits. Exploiting a correspondence between the set of periodic orbits and the set of rational numbers, we are able to construct periodic tables of orbits and energy level diagrams of the accessible states around black holes. We also present a closed-form expression for the rational q, thereby quantifying zoom-whirl behavior in terms of spin, energy and angular momentum. The black hole atom is not just a theoretical construct, but corresponds to extant astrophysical systems detectable by future gravitational wave observatories.

  9. Towards Flexibility Detection in Device-Level Energy Consumption

    DEFF Research Database (Denmark)

    Neupane, Bijay; Pedersen, Torben Bach; Thiesson, Bo

    2014-01-01

    The increasing drive towards green energy has boosted the installation of Renewable Energy Sources (RES). Increasing the share of RES in the power grid requires demand management by flexibility in the consumption. In this paper, we perform a state-of-the-art analysis on the flexibility and operat......The increasing drive towards green energy has boosted the installation of Renewable Energy Sources (RES). Increasing the share of RES in the power grid requires demand management by flexibility in the consumption. In this paper, we perform a state-of-the-art analysis on the flexibility...... and operation patterns of the devices in a set of real households. We propose a number of specific pre-processing steps such as operation stage segmentation, and aberrant operation duration removal to clean device level data. Further, we demonstrate various device operation properties such as hourly and daily...... regularities and patterns and the correlation between operating different devices. Subsequently, we show the existence of detectable time and energy flexibility in device operations. Finally, we provide various results providing a foundation for load- and flexibility-detection and -prediction at the device...

  10. Structural analysis of the ITER Vacuum Vessel regarding 2012 ITER Project-Level Loads

    Energy Technology Data Exchange (ETDEWEB)

    Martinez, J.-M., E-mail: jean-marc.martinez@live.fr [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul lez Durance (France); Jun, C.H.; Portafaix, C.; Choi, C.-H.; Ioki, K.; Sannazzaro, G.; Sborchia, C. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul lez Durance (France); Cambazar, M.; Corti, Ph.; Pinori, K.; Sfarni, S.; Tailhardat, O. [Assystem EOS, 117 rue Jacquard, L' Atrium, 84120 Pertuis (France); Borrelly, S. [Sogeti High Tech, RE2, 180 rue René Descartes, Le Millenium – Bat C, 13857 Aix en Provence (France); Albin, V.; Pelletier, N. [SOM Calcul – Groupe ORTEC, 121 ancien Chemin de Cassis – Immeuble Grand Pré, 13009 Marseille (France)

    2014-10-15

    Highlights: • ITER Vacuum Vessel is a part of the first barrier to confine the plasma. • ITER Vacuum Vessel as Nuclear Pressure Equipment (NPE) necessitates a third party organization authorized by the French nuclear regulator to assure design, fabrication, conformance testing and quality assurance, i.e. Agreed Notified Body (ANB). • A revision of the ITER Project-Level Load Specification was implemented in April 2012. • ITER Vacuum Vessel Loads (seismic, pressure, thermal and electromagnetic loads) were summarized. • ITER Vacuum Vessel Structural Margins with regards to RCC-MR code were summarized. - Abstract: A revision of the ITER Project-Level Load Specification (to be used for all systems of the ITER machine) was implemented in April 2012. This revision supports ITER's licensing by accommodating requests from the French regulator to maintain consistency with the plasma physics database and our present understanding of plasma transients and electro-magnetic (EM) loads, to investigate the possibility of removing unnecessary conservatism in the load requirements and to review the list and definition of incidental cases. The purpose of this paper is to present the impact of this 2012 revision of the ITER Project-Level Load Specification (LS) on the ITER Vacuum Vessel (VV) loads and the main structural margins required by the applicable French code, RCC-MR.

  11. Vitamin A levels and human immunodeficiency virus load in injection drug users.

    Science.gov (United States)

    Semba, R D; Farzadegan, H; Vlahov, D

    1997-01-01

    Although low plasma vitamin A levels are associated with increased mortality and higher vertical transmission during human immunodeficiency virus (HIV) infection, it is unknown whether plasma low vitamin A levels are a marker for circulating HIV load. We conducted a cross-sectional study within a prospective cohort study of injection drug users in order to evaluate the relationship between plasma vitamin A levels and HIV viral load. Plasma vitamin A level was measured by high-performance liquid chromatography. Infectious viral load was measured by quantitative microculture of serial fivefold dilutions of 10(6) peripheral blood mononuclear cells. A total of 284 HIV-infected adults (79 women, 205 men) were studied. Plasma vitamin A levels consistent with deficiency were found in 28.9% of adults. A total of 38.0% of women and 25.3% of men had vitamin A deficiency (P < 0.04). The median infectious viral load for the entire study population was 8 infectious units per million cells. No significant relationship between plasma vitamin A levels and infectious viral load was observed in these injection drug users. This study suggests that there is no correlation between HIV viral load and plasma vitamin A levels in injection drug users, and these variables may represent independent risk factors during HIV infection. HIV-infected adult women appear to be at higher risk of developing vitamin A deficiency. PMID:9008289

  12. effects of bud loading levels and different nitrogen doses on the ...

    African Journals Online (AJOL)

    USER

    2011-09-28

    Sep 28, 2011 ... in 100 g samples, leaf area for physical properties; dry matter, ash, pH and titratable ... Keywords: Brined-grape leaves, nitrogen, bud loading level, narince grape cultivar, Turkey. ..... Agriculture Organization (2010). www.

  13. EFFECT OF DIFFERENT LEVELS AGROECOLOGICAL LOADS ON BIOCHEMICAL CHARACTERISTICS OF SOIL

    OpenAIRE

    A. V. Shchur; D. V. Vinogradov; V. P. Valckho

    2016-01-01

    Aim. To study the effect of different levels of agri-environmental loads on the enzymatic activity of the soil.Methods. Isolation of soil fauna was conducted by thermogradient. Ecological characteristics of soil biota community was determined by ecological indices. The enzymatic activity of soil under different crops and at different levels of agri-environmental loads in our experiments was determined by methods proven in the laboratory soil enzymology Institute of Experimental Botany name V....

  14. Energy efficiency - The struggle for load management is raging. The French Riviera redoubles savings

    International Nuclear Information System (INIS)

    Moragues, Manuel; Barla, Jean-Christophe

    2014-01-01

    A first article discusses the debate initiated by a decree on load management associated with the French Brottes law on energy. Load management is the possibility for consumers to reduce their consumption at peak hours. Electricity producers and suppliers are of course against, whereas new actors (load managers or aggregators) are for. The issue is then to determine who will pay this managed (and not consumed) energy. The article also evokes a controversy about the Brottes law which creates a bonus to subsidy load management, and comments the development of this load management market and its legal framework. A second article describes actions undertaken by industries of the French Riviera to manage their energy consumption

  15. The effects of variable renewable electricity on energy efficiency and full load hours of fossil-fired power plants in the European Union

    NARCIS (Netherlands)

    de Groot, Mats; Crijns-Graus, Wina; Harmsen, Robert

    2017-01-01

    This study focused on the effects of variable renewable electricity (VRE) on full load hours and energy efficiency of fossil-fired power generation in the European Union from 1990-2014. Member states were aggregated into three groups based on the level of VRE penetration. Average full load hours are

  16. Evolution strategy based optimal chiller loading for saving energy

    International Nuclear Information System (INIS)

    Chang, Y.-C.; Lee, C.-Y.; Chen, C.-R.; Chou, C.-J.; Chen, W.-H.; Chen, W.-H.

    2009-01-01

    This study employs evolution strategy (ES) to solve optimal chiller loading (OCL) problem. ES overcomes the flaw that Lagrangian method is not adaptable for solving OCL as the power consumption models or the kW-PLR (partial load ratio) curves include convex functions and concave functions simultaneously. The complicated process of evolution by the genetic algorithm (GA) method for solving OCL can also be simplified by the ES method. This study uses the PLR of chiller as the variable to be solved for the decoupled air conditioning system. After analysis and comparison of the case study, it has been concluded that this method not only solves the problems of Lagrangian method and GA method, but also produces results with high accuracy within a rapid timeframe. It can be perfectly applied to the operation of air conditioning systems

  17. Multi-Level Energy Management and Optimal Control of a Residential DC Microgrid

    DEFF Research Database (Denmark)

    Diaz, Enrique Rodriguez; Anvari-Moghaddam, Amjad; Quintero, Juan Carlos Vasquez

    2017-01-01

    of a residential DC microgrid (R-DCMG) with different distributed generations (DGs) and loads is proposed and implemented as an optimal hierarchical control strategy. A system-level optimizer is designed to calculate the optimal operating points of the controllable energy sources (CESs) when needed, while lower......-level controllers are utilized to enforce the CESs to follow optimal set-points....

  18. Fat or lean: adjustment of endogenous energy stores to predictable and unpredictable changes in allostatic load

    Science.gov (United States)

    Schultner, Jannik; Kitaysky, Alexander S.; Welcker, Jorg; Hatch, Scott

    2013-01-01

    1. The ability to store energy endogenously is an important ecological mechanism that allows animals to buffer predictable and unpredictable variation in allostatic load. The secretion of glucocorticoids, which reflects changes in allostatic load, is suggested to play a major role in the adjustment of endogenous stores to these varying conditions.

  19. Investigation on energy storage and quick load change control of subcritical circulating fluidized bed boiler units

    International Nuclear Information System (INIS)

    Gao, Mingming; Hong, Feng; Liu, Jizhen

    2017-01-01

    Highlights: • The model of energy storage of subcritical CFB boilers is established. • The capacity and increment rate of heat storage are quantified. • A novel load control strategy is proposed to improve the quick load change ability. • An application on the 300 MW CFB unit proves the load change rate to 5–8 MW/min. - Abstract: The energy storage of circulating fluidized bed (CFB) boilers on fuel side cannot be ignored due to the special combustion type different from pulverized coal boilers. The sizable energy storage makes it possible for CFB units to enhance the quick load change ability and to increase the scale of new energy power connected into grid. Through mechanism analysis, the model of energy storage of subcritical CFB boilers has been established for the first time. Then by the project practice, the quantitative analysis is demonstrated for the capacity and control characteristics of energy storage on fuel side and steam water side. Based on the control characteristics and the transformation of the energy storage, a coordinated control system (CCS) control strategy named advanced energy balance (AEB) is designed to shorten the response time through the use of energy storage and to accelerate the load change speed of subcritical CFB units. Finally, a case study on a 300 MW CFB unit proves the feasibility of the proposed control strategy.

  20. Electricity's "Disappearing Act": Understanding Energy Consumption and Phantom Loads

    Science.gov (United States)

    Rusk, Bryan; Mahfouz, Tarek; Jones, James

    2011-01-01

    Energy exists in many forms and can be converted from one form to another. However, this conversion is not 100% efficient, and energy is lost in the form of heat during conversion. In addition, approximately 6% of the monthly consumption of the average American household's electricity is neither lost nor used by its residents. These losses are…

  1. Peak-load pricing and thermal energy storage

    Energy Technology Data Exchange (ETDEWEB)

    1979-01-01

    Twenty papers were presented at the meeting. A separate abstract was prepared for each of 19 papers. One paper was processed previously for the Energy Data Base (EDB). Fifteen of the papers were processed for inclusion in Energy Abstracts for Policy Analysis (EAPA). (LCL)

  2. Impact behaviour of Napier/polyester composites under different energy levels

    Energy Technology Data Exchange (ETDEWEB)

    Fahmi, I., E-mail: fahmi-unimap@yahoo.com; Majid, M. S. Abdul, E-mail: shukry@unimap.edu.my; Afendi, M., E-mail: afendirojan@unimap.edu.my; Haameem, J. M.A., E-mail: mhaameem@gmail.com [School of Mechatronic Engineering, Universiti Malaysia Perlis, Arau (Malaysia); Haslan, M., E-mail: haslan@sirim.my; Helmi, E. A., E-mail: hilmi@sirim.my [Advanced Material Research Centre (AMREC), SIRIM Berhad, Kulim (Malaysia)

    2016-07-19

    The effects of different energy levels on the impact behaviour of Napier fibre/polyester reinforced composites were investigated. Napier fibre was extracted using traditional water retting process to be utilized as reinforcing materials in polyester composite laminates. 25% fibre loading composite laminates were prepared and impacted at three different energy levels; 2.5,5 and 7.5 J using an instrumented drop weight impact testing machine (IMATEK IM10). The outcomes show that peak force and contact time increase with increased impact load. The energy absorption was then calculated from the force displacement curve. The results indicated that the energy absorption decreases with increasing energy levels of the impact. Impacted specimens were observed visually for fragmentation fracture using an optical camera to identify the failure mechanisms. Fracture fragmentation pattern from permanent dent to perforation with radial and circumferential was observed.

  3. Green IGP Link Weights for Energy-efficiency and Load-balancing in IP Backbone Networks

    OpenAIRE

    Francois, Frederic; Wang, Ning; Moessner, Klaus; Georgoulas, Stylianos; Xu, Ke

    2013-01-01

    The energy consumption of backbone networks has become a primary concern for network operators and regulators due to the pervasive deployment of wired backbone networks to meet the requirements of bandwidth-hungry applications. While traditional optimization of IGP link weights has been used in IP based load-balancing operations, in this paper we introduce a novel link weight setting algorithm, the Green Load-balancing Algorithm (GLA), which is able to jointly optimize both energy efficiency ...

  4. ENERGY EFFICIENCY DETERMINATION OF LOADING-BACK SYSTEM OF ELECTRIC TRACTION MACHINES

    Directory of Open Access Journals (Sweden)

    A. M. Afanasov

    2014-03-01

    Full Text Available Purpose.Acceptance post-repair testsof electric traction machinesare conducted onloading-backstandsthat reducethe overall power costsfor the tests.Currentlya numberof possiblecircuit designs of loading-backsystems of electric machines are known, but there is nomethod of determiningtheir energy efficiency. This in turn makes difficult the choiceof rationaloptions. The purpose of the article is the development of the corresponding methodo-logy to make easier this process. Methodology. Expressions for determining theenergy efficiency ofa stand for testingof electric traction machineswere obtained using the generalizedscheme analysisof energy transformationsin the loading-backsystems of universal structure. Findings.Thetechnique wasoffered and the analytical expressions for determining the energy efficiency of loading-backsystemsof electric traction machines wereobtained. Energy efficiency coefficientofloading-backsystemisproposed to consider as the ratio of the total actionenergy of the mechanical and electromotive forces, providing anchors rotation and flowof currents in electric machines, which are being tested,to the total energy, consumed during the test from the external network. Originality. The concept was introduced and the analytical determination method of the energy efficiency of loading-backsystem in electric traction machines was offered. It differs by efficiency availability of power sources and converters, as well as energy efficiency factors of indirect methods of loss compensation. Practical value. The proposed technique of energy efficiency estimation of a loading-backsystemcan be used in solving the problem of rational options choice of schematics stands decisions for electric traction machines acceptance tests of main line and industrial transport.

  5. Preliminary Load Estimations for DEXA Wave Energy Device - Hanstholm, Denmark

    DEFF Research Database (Denmark)

    Kofoed, Jens Peter

    by DEXA Wave Energy ApS, in regular and irregular wave states, as described in Assessment of Wave Energy Devices. Best Practice as used in Denmark (Frigaard et al., 2008). The length scale of the model was 1:20 compared to a full scale device suitable fro the Danish part of the North Sea, according...... to DEXA Wave Energy ApS. The tests were carried out at Dept. of Civil Engineering, Aalborg University (AAU) in the 3D deep water wave tank. The displacement and force applied to a power take off system, provided by DEXA Wave Energy ApS, were measured and used for calculation of power available...... to the power take-off....

  6. Renewable energy education at the University level

    Energy Technology Data Exchange (ETDEWEB)

    Bhattacharya, S.C. [Asian Institute of Technology, Pathumthani (Thailand). Energy Program

    2001-03-01

    The rapid growth in global enrolment of students for higher education observed in recent decades is expected to continue in the early next century. However, the role of the universities and their approach to education may undergo substantial transformation in the future. The Internet is expected to play a significant role in university-level education in general and renewable energy education (REE) in particular. Currently, REE at different universities is characterized by a lack of uniformity in terms of duration, coursework, emphasis on research, etc. There is a need to establish guidelines and standards regarding academic programs and to establish a system of accreditation, preferably global, of REE in different academic disciplines and departments. (author)

  7. Experimental research of plastic scintillation detector loaded 6Li neutron energy response

    International Nuclear Information System (INIS)

    Wang Lizong; Zhang Chuanfei; Peng Taiping; Guo Cun; Yang Hongqiong; Zhang Jianhua

    2005-01-01

    A new plastic scintillator, plastic scintillator loaded 6 Li, is brought forward and developed in this paper in order to increase low energy neutron sensitivity. Neutron sensitivity of several plastic scintillation detectors loaded 6 Li new developed in neutron energy range 0.2 MeV-5.0 MeV are calibrated by direct current at serial accelerator. Energy response curves of the detectors are obtained in this experiment. It is shown that this new plastic scintillation detector can increase low energy neutron sensitivity in experimental results. (authors)

  8. An optimal control model for load shifting - With application in the energy management of a colliery

    International Nuclear Information System (INIS)

    Middelberg, Arno; Zhang Jiangfeng; Xia Xiaohua

    2009-01-01

    This paper presents an optimal control model for the load shifting problem in energy management and its application in a South African colliery. It is illustrated in the colliery scenario that how the optimal control model can be applied to optimize load shifting and improve energy efficiency through the control of conveyor belts. The time-of-use electricity tariff is used as an input to the objective function in order to obtain a solution that minimizes electricity costs and thus maximizes load shifting. The case study yields promising results that show the potential of applying this optimal control model to other industrial Demand Side Management initiatives

  9. Load Situation Awareness Design for Integration in Multi-Energy System

    DEFF Research Database (Denmark)

    Cai, Hanmin; You, Shi; Bindner, Henrik W.

    2017-01-01

    Renewable Energy Sources (RESs) have been penetrating in power system at a staggering pace in recent years. Their intermittent nature is, however, posing great threat to system operation. Recently, active load management has been suggested as a tool to counteract these side effects. In multi......-energy system, thermal load management will benefit not only electric network but also district heating network. Electric heater will be the main focus of this paper as a common thermal load. A situation awareness framework for its integration into electric and district heating network will be proposed...

  10. Research on Energy-Saving Design of Overhead Travelling Crane Camber Based on Probability Load Distribution

    Directory of Open Access Journals (Sweden)

    Tong Yifei

    2014-01-01

    Full Text Available Crane is a mechanical device, used widely to move materials in modern production. It is reported that the energy consumptions of China are at least 5–8 times of other developing countries. Thus, energy consumption becomes an unavoidable topic. There are several reasons influencing the energy loss, and the camber of the girder is the one not to be neglected. In this paper, the problem of the deflections induced by the moving payload in the girder of overhead travelling crane is examined. The evaluation of a camber giving a counterdeflection of the girder is proposed in order to get minimum energy consumptions for trolley to move along a nonstraight support. To this aim, probabilistic payload distributions are considered instead of fixed or rated loads involved in other researches. Taking 50/10 t bridge crane as a research object, the probability loads are determined by analysis of load distribution density functions. According to load distribution, camber design under different probability loads is discussed in detail as well as energy consumptions distribution. The research results provide the design reference of reasonable camber to obtain the least energy consumption for climbing corresponding to different P0; thus energy-saving design can be achieved.

  11. Assessment of building integrated energy supply and energy saving schemes on a national level in Denmark

    Energy Technology Data Exchange (ETDEWEB)

    Muenster, M.; Morthorst, P.E.; Birkl, C.

    2011-06-15

    In the future, buildings will not only act as consumers of energy but as producers as well. For these ''prosumers'', energy production by use of solar panels, photovoltaics and heat pumps etc will be essential. The objective of this project was to find the most optimal combinations of building insulation and use of renewable energy sources in existing buildings in terms of economics and climate impacts. Five houses were analyzed based on different personal load, consumption profiles, solar orientation and proposed building envelope improvements and use of combinations of renewable energy systems. The results of these analyses were integrated in five scenarios to examine the consequences at national level of implementing insulation together with solar panels, photovoltaics and heat pumps in single-family houses. The simulations focused on the building period between 1961 and 1972 characterised by high building activity and low energy performance. The five scenarios - a baseline scenario, a maximum savings scenario, a maximum production scenario, and a combination scenario - showed that regardless of scenario, a consequent use of individual heat pumps leads to the greatest energy savings and CO{sub 2} reductions. (ln)

  12. Single Enteral Loading Dose of Phenobarbital for Achieving Its Therapeutic Serum Levels in Neonates

    Science.gov (United States)

    Turhan, Ali H.; Atici, Aytug; Okuyaz, Cetin; Uysal, Sercan

    2010-01-01

    Aim To investigate whether therapeutic serum drug levels may be achieved with a single enteral loading dose of phenobarbital. Methods The study was performed at the Mersin University Hospital in Turkey between April 2004 and August 2006, and included 29 newborn babies with seizure. After the acute treatment of the seizure with midazolam at a dose of 0.1 mg/kg, phenobarbital was administered by orogastric route at a loading dose of 20 mg/kg. Serum phenobarbital concentrations were measured at 0.5, 3, 6, and 12 hours after the loading. Serum phenobarbital levels between 10-30 μg/mL were considered as the therapeutic range. Results The serum phenobarbital levels reached therapeutic values in 9 (31%), 19 (66%), 21 (72%), and 23 (79%) patients at 0.5, 3, 6, and 12 hours after loading, respectively, while they did not reach therapeutic values in 6 patients (21%) after 12 hours. Four of the patients in whom there was no increase in serum phenobarbital levels had hypoxic-ischemic encephalopathy. Conclusion Enteral loading of phenobarbital can achieve therapeutic serum levels in the large majority of newborn babies with seizure and may be safely used in babies with the intact gastrointestinal tract. PMID:20564764

  13. The effect of cognitive load on adaptation to differences in steering wheel force feedback level

    NARCIS (Netherlands)

    Anand, S.; Terken, J.; Hogema, J.

    2013-01-01

    In an earlier study it was found that drivers can adjust quickly to different force feedback levels on the steering wheel, even for such extreme levels as zero feedback. It was hypothesized that, due to lack of cognitive load, participants could easily and quickly learn how to deal with extreme

  14. Mobile loading transuranic waste at small quantity sites in the Department of Energy complex-10523

    International Nuclear Information System (INIS)

    Carter, Mitch; Howard, Bryan; Weyerman, Wade; Mctaggart, Jerri

    2009-01-01

    Los Alamos National Laboratory, Carlsbad Office (LANL-CO), operates mobile loading operations for all of the large and small quantity transuranic (TRU) waste sites in the Department of Energy (DOE) complex. The mobile loading team performs loading and unloading evolutions for both contact handled (CH) and remote handled (RH) waste. For small quantity sites, many of which have yet to remove their TRU waste, the mobile loading team will load shipments that will ship to Idaho National Laboratory, a centralization site, or ship directly to the Waste Isolation Pilot Plant (WIPP). For example, Argonne National Laboratory and General Electric Vallecitos Nuclear Center have certified programs for RH waste so they will ship their RH waste directly to WIPP. Many of the other sites will ship their waste to Idaho for characterization and certification. The Mobile Loading Units (MLU) contain all of the necessary equipment needed to load CH and RH waste into the appropriate shipping vessels. Sites are required to provide additional equipment, such as cranes, fork trucks, and office space. The sites are also required to provide personnel to assist in the shipping operations. Each site requires a site visit from the mobile loading team to ensure that all of the necessary site equipment, site requirements and space for shipping can be provided. The mobile loading team works diligently with site representatives to ensure that all safety and regulatory requirements are met. Once the waste is ready and shipping needs are met, the mobile loading team can be scheduled to ship the waste. The CH MLU is designed to support TRUPACT-II and HalfPACT loading activities wherever needed within the DOE complex. The team that performs the mobile loading operation has obtained national certification under DOE for TRUPACT-II and HalfPACT loading and shipment certification. The RH MLU is designed to support removable lid canister (RLC) and RH-72B cask loading activities wherever needed within the DOE

  15. Is there an optimum level for renewable energy?

    International Nuclear Information System (INIS)

    Moriarty, Patrick; Honnery, Damon

    2011-01-01

    Because continued heavy use of fossil fuel will lead to both global climate change and resource depletion of easily accessible fuels, many researchers advocate a rapid transition to renewable energy (RE) sources. In this paper we examine whether RE can provide anywhere near the levels of primary energy forecast by various official organisations in a business-as-usual world. We find that the energy costs of energy will rise in a non-linear manner as total annual primary RE output increases. In addition, increasing levels of RE will lead to increasing levels of ecosystem maintenance energy costs per unit of primary energy output. The result is that there is an optimum level of primary energy output, in the sense that the sustainable level of energy available to the economy is maximised at that level. We further argue that this optimum occurs at levels well below the energy consumption forecasts for a few decades hence. - Highlights: → We need to shift to renewable energy for climate change and fuel depletion reasons. → We examine whether renewable energy can provide the primary energy levels forecast. → The energy costs of energy rise non-linearly with renewable energy output. → There is thus an optimum level of primary energy output. → This optimum occurs at levels well below future official energy use forecasts.

  16. Marketing conception interaction between power system and electric energy loads

    International Nuclear Information System (INIS)

    Bagiev, G.L.; Shneerova, G.V.; Taratin, V.A.; Barykin, E.E.; Zajtsev, O.V.

    1993-01-01

    New concept of functioning fuel-power complex, based on the marketing system is, is presented in brief form. This system includes demand management program, working policy program, active energy-saving policy program and advertisment-service organization program. Methods for realization of demand management and working policy programs are considered

  17. Energy savings in mobile broadband network based on load predictions

    DEFF Research Database (Denmark)

    Samulevicius, Saulius; Pedersen, Torben Bach; Sørensen, Troels Bundgaard

    2012-01-01

    Abstract—The deployment of new network equipment is resulting in increasing energy consumption in mobile broadband networks (MBNs). This contributes to higher CO2 emissions. Over the last 10 years MBNs have grown considerably, and are still growing to meet the evolution in traffic volume carried...

  18. Analysis of recurrent neural networks for short-term energy load forecasting

    Science.gov (United States)

    Di Persio, Luca; Honchar, Oleksandr

    2017-11-01

    Short-term forecasts have recently gained an increasing attention because of the rise of competitive electricity markets. In fact, short-terms forecast of possible future loads turn out to be fundamental to build efficient energy management strategies as well as to avoid energy wastage. Such type of challenges are difficult to tackle both from a theoretical and applied point of view. Latter tasks require sophisticated methods to manage multidimensional time series related to stochastic phenomena which are often highly interconnected. In the present work we first review novel approaches to energy load forecasting based on recurrent neural network, focusing our attention on long/short term memory architectures (LSTMs). Such type of artificial neural networks have been widely applied to problems dealing with sequential data such it happens, e.g., in socio-economics settings, for text recognition purposes, concerning video signals, etc., always showing their effectiveness to model complex temporal data. Moreover, we consider different novel variations of basic LSTMs, such as sequence-to-sequence approach and bidirectional LSTMs, aiming at providing effective models for energy load data. Last but not least, we test all the described algorithms on real energy load data showing not only that deep recurrent networks can be successfully applied to energy load forecasting, but also that this approach can be extended to other problems based on time series prediction.

  19. Automatic control of the water level of steam generators from 0% to 100% of the load

    International Nuclear Information System (INIS)

    Hocepied, R.; Debelle, J.; Timmermans, A.; Lams, J.-L.; Baeyens, R.; Eussen, G.; Bassem, G.

    1978-01-01

    The water level of a steam generator is hard to control manually and it is practically impossible for a human operator to react correctly to every important perturbation. These phenomena are further accentuated during the start-up at low load and at low feedwater temperature. The control schemes traditionally provided do not permit satisfactory automatic level control during all operating circumstances. Adaptions of the control system permit all the problems encountered to be solved: automatic control of the level in the steam generators is possible from 0% to 100% of the load and also when large-scale perturbations occur. Such a result has been obtained by use of systematic methods for the analysis of the steam generator's behaviour. These methods have also been used to verify the performance of the control system. The control system installed at the Doel nuclear power station prevents most of the reactor or turbine trip-outs caused by level deviations occurring during start-up and low-load operation. It also minimizes the effects on the unit of incidents such as tripping the unit on house load, safety tripping, fast run-back on reduced load, etc. The principles used are applicable to the control of steam generators of all pressurized water reactor power stations. (author)

  20. Air pollution and impact on eco-systems. Load concept/critical level and its consequences

    International Nuclear Information System (INIS)

    Elichegaray, C.

    1993-01-01

    Critical loads and critical levels respectively can be defined as the deposition value, or the concentration of pollutants in the atmosphere, above which adverse effects on receptors such as plants, ecosystems, materials may occur. Important research is currently being developed on critical loads and levels in the framework of the Geneva convention on transboundary air pollution. Several binding protocols have been elaborated between the european countries, the Canada, and the USA, to reduce their emissions of sulphur, nitrogen oxides, volatile organic compounds. This article describes the critical loads and levels approach, and the way by which this concept is now used for the revision of the sulphur protocol. (author). 6 refs., 5 figs., 4 tabs

  1. Blood pressure load does not add to ambulatory blood pressure level for cardiovascular risk stratification

    DEFF Research Database (Denmark)

    Li, Yan; Thijs, Lutgarde; Boggia, José

    2014-01-01

    Experts proposed blood pressure (BP) load derived from 24-hour ambulatory BP recordings as a more accurate predictor of outcome than level, in particular in normotensive people. We analyzed 8711 subjects (mean age, 54.8 years; 47.0% women) randomly recruited from 10 populations. We expressed BP...... load as percentage (%) of systolic/diastolic readings ≥135/≥85 mm Hg and ≥120/≥70 mm Hg during day and night, respectively, or as the area under the BP curve (mm Hg×h) using the same ceiling values. During a period of 10.7 years (median), 1284 participants died and 1109 experienced a fatal or nonfatal...... cardiovascular end point. In multivariable-adjusted models, the risk of cardiovascular complications gradually increased across deciles of BP level and load (Pbased on 24-hour systolic or diastolic BP level (generalized R(2) statistic ≤0.294%; net...

  2. Energy management for vehicle power net with flexible electric load demand

    NARCIS (Netherlands)

    Kessels, J.T.B.A.; Bosch, van den P.P.J.; Koot, M.W.T.; Jager, de A.G.

    2005-01-01

    The electric power demand in road vehicles increases rapidly and to supply all electric loads efficiently, energy management (EM) turns out to be a necessity. In general, EM exploits the storage capacity of a buffer connected to the vehicle's power net, such that energy is stored or retrieved at

  3. Modulation of weight off-loading level over body-weight supported locomotion training.

    Science.gov (United States)

    Wang, Ping; Low, K H; Lim, Peter A C; McGregor, A H

    2011-01-01

    With the evolution of robotic systems to facilitate overground walking rehabilitation, it is important to understand the effect of robotic-aided body-weight supported loading on lower limb muscle activity, if we are to optimize neuromotor recovery. To achieve this objective, we have collected and studied electromyography (EMG) data from key muscles in the lower extremity from healthy subjects walking over a wide range of body-weight off-loading levels as provided by a bespoke gait robot. By examining the impact of body-weight off-loading, it was found that muscle activation patterns were sensitive to the level of off-loading. In addition, a large off-loading might introduce disturbance of muscle activation pattern, led to a wider range of motion in terms of dorsiflexion/plantarflexion. Therefore, any future overground training machine should be enhanced to exclude unnecessary effect of body off-loading in securing the sustaining upright posture and providing assist-as-needed BWS over gait rehabilitation. © 2011 IEEE

  4. Load management as a smart grid concept for sizing and designing of hybrid renewable energy systems

    Science.gov (United States)

    Eltamaly, Ali M.; Mohamed, Mohamed A.; Al-Saud, M. S.; Alolah, Abdulrahman I.

    2017-10-01

    Optimal sizing of hybrid renewable energy systems (HRES) to satisfy load requirements with the highest reliability and lowest cost is a crucial step in building HRESs to supply electricity to remote areas. Applying smart grid concepts such as load management can reduce the size of HRES components and reduce the cost of generated energy considerably. In this article, sizing of HRES is carried out by dividing the load into high- and low-priority parts. The proposed system is formed by a photovoltaic array, wind turbines, batteries, fuel cells and a diesel generator as a back-up energy source. A smart particle swarm optimization (PSO) algorithm using MATLAB is introduced to determine the optimal size of the HRES. The simulation was carried out with and without division of the load to compare these concepts. HOMER software was also used to simulate the proposed system without dividing the loads to verify the results obtained from the proposed PSO algorithm. The results show that the percentage of division of the load is inversely proportional to the cost of the generated energy.

  5. Energy Savings in Cellular Networks Based on Space-Time Structure of Traffic Loads

    Science.gov (United States)

    Sun, Jingbo; Wang, Yue; Yuan, Jian; Shan, Xiuming

    Since most of energy consumed by the telecommunication infrastructure is due to the Base Transceiver Station (BTS), switching off BTSs when traffic load is low has been recognized as an effective way of saving energy. In this letter, an energy saving scheme is proposed to minimize the number of active BTSs based on the space-time structure of traffic loads as determined by principal component analysis. Compared to existing methods, our approach models traffic loads more accurately, and has a much smaller input size. As it is implemented in an off-line manner, our scheme also avoids excessive communications and computing overheads. Simulation results show that the proposed method has a comparable performance in energy savings.

  6. Inclusion of Structural Flexibility in Design Load Analysis for Wave Energy Converters: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Yi [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Yu, Yi-Hsiang [National Renewable Energy Laboratory (NREL), Golden, CO (United States); van Rij, Jennifer A [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Tom, Nathan M [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-08-14

    Hydroelastic interactions, caused by ocean wave loading on wave energy devices with deformable structures, are studied in the time domain. A midfidelity, hybrid modeling approach of rigid-body and flexible-body dynamics is developed and implemented in an open-source simulation tool for wave energy converters (WEC-Sim) to simulate the dynamic responses of wave energy converter component structural deformations under wave loading. A generalized coordinate system, including degrees of freedom associated with rigid bodies, structural modes, and constraints connecting multiple bodies, is utilized. A simplified method of calculating stress loads and sectional bending moments is implemented, with the purpose of sizing and designing wave energy converters. Results calculated using the method presented are verified with those of high-fidelity fluid-structure interaction simulations, as well as low-fidelity, frequency-domain, boundary element method analysis.

  7. Effect of load eccentricity and stress level on monopile support for offshore wind turbines

    DEFF Research Database (Denmark)

    Klinkvort, Rasmus Tofte; Hededal, Ole

    2014-01-01

    on which load is applied with a large eccentricity. With centrifuge tests as the basis, this paper investigates the behaviour of a rigid pile loaded with a high eccentricity. A test series was carried out to simulate idealized monotonic load cases for monopiles supporting an offshore wind turbine....... Centrifuge tests were performed on model monopiles subjected to stress distributions equal to prototype monopiles with pile diameters ranging from 1–5 m and eccentricities ranging from 8.25–17.75 pile diameters. It was possible to identify a unified response of all of these tests by using dimensional...... analysis and Rankine’s passive earth pressure coefficient as a normalization parameter. The normalized ultimate soil resistance was unaffected by acceleration level and load eccentricity, indicating that the failure mechanism was the same for all tests. Based on the centrifuge tests, a reformulation...

  8. Levelized Cost of Energy of the Weptos wave energy converter

    DEFF Research Database (Denmark)

    Pecher, Arthur; Kofoed, Jens Peter

    This report presents the cost of energy calculations of a wave energy array of 90 MW, consisting of 25 x 3.6 MW Weptos wave energy converters. The calculation has been made in analogy with a publically available document presented by the UK government, covering the case of a similar size wind...

  9. Association of Post-Saline Load Plasma Aldosterone Levels With Left Ventricular Hypertrophy in Primary Hypertension.

    Science.gov (United States)

    Catena, Cristiana; Verheyen, Nicolas D; Url-Michitsch, Marion; Kraigher-Krainer, Elisabeth; Colussi, GianLuca; Pilz, Stefan; Tomaschitz, Andreas; Pieske, Burkert; Sechi, Leonardo A

    2016-03-01

    Left ventricular hypertrophy (LVH) is an independent risk factor for cardiovascular morbidity in hypertension. Current evidence suggests a contribution to LVH of plasma aldosterone levels that are inappropriately elevated for the salt status. The aim of this study was to investigate whether inappropriate modulation of aldosterone production by a saline load is associated with left ventricular (LV) mass in hypertensive patients. In 90 hypertensive patients free of clinically relevant cardiovascular complications in whom secondary forms of hypertension were ruled out, we performed a standard intravenous saline load (0.9% NaCl, 2 l in 4 hours) with measurement of plasma aldosterone and active renin at baseline and end of infusion. Bi-dimensional echocardiography was performed for the assessment of cardiac morphology and function. LVH was present in 19% of patients who had significantly worse renal function and higher body mass, blood pressure, and plasma aldosterone levels measured both at baseline and after the saline load than patients without LVH. LV mass was directly related to age, body mass, systolic blood pressure, duration of hypertension, baseline, and post-saline load plasma aldosterone levels and inversely to glomerular filtration. Multivariate regression analysis showed independent correlation of LV mass with body mass, systolic blood pressure, and plasma aldosterone levels measured after intravenous saline load, but not at baseline. In patients with hypertension, aldosterone levels measured after intravenous saline load are related to LV mass independent of age, body mass, and blood pressure, suggesting that limited ability of salt to modulate aldosterone production could contribute to LVH. © American Journal of Hypertension, Ltd 2015. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. EPB standard EN ISO 52016: calculation of the building’s energy needs for heating and cooling, internal temperatures and heating and cooling load

    NARCIS (Netherlands)

    Dijk, H.A.L. van; Spiekman, M.E.; Hoes-van Oeffelen, E.C.M.

    2016-01-01

    EN ISO 52016-1 presents a coherent set of calculation methods at different levels of detail, for the (sensible) energy needs for the space heating and cooling and (latent) energy needs (de)humidification of a building and/or internal temperatures and heating and/or cooling loads, including the

  11. Analytic model for ultrasound energy receivers and their optimal electric loads II: Experimental validation

    Science.gov (United States)

    Gorostiaga, M.; Wapler, M. C.; Wallrabe, U.

    2017-10-01

    In this paper, we verify the two optimal electric load concepts based on the zero reflection condition and on the power maximization approach for ultrasound energy receivers. We test a high loss 1-3 composite transducer, and find that the measurements agree very well with the predictions of the analytic model for plate transducers that we have developed previously. Additionally, we also confirm that the power maximization and zero reflection loads are very different when the losses in the receiver are high. Finally, we compare the optimal load predictions by the KLM and the analytic models with frequency dependent attenuation to evaluate the influence of the viscosity.

  12. Mapping critical levels/loads for the Slovak Republic. Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Zavodsky, D; Babiakova, G; Mitosinkova, M [and others

    1996-08-01

    As a part of the Agreement on Environmental Cooperation between Norway and Slovakia a project ``Mapping Critical Levels/Loads for Slovakia`` was established. This report presents the final project results. Critical loads for forest, surface and ground waters and their exceedances were calculated by means of the steady-state mass balance model PROFILE for soils, and the steady-state water chemistry method for waters. A grid distance of 10 km was used. Because the sulphur deposition has been decreasing, the exceedances of critical load of acidity and critical sulphur deposition of forest soils have decreased from 1990 to 1995. Practically no acidity exceedances for surface water or ground water were found in 1995. The critical level of forest ozone was exceeded all over Slovakia. In the Tatra mountains the exceedance was over 25000 ppb.h. 23 refs., 3 figs., 3 tabs.

  13. Load Balancing Integrated Least Slack Time-Based Appliance Scheduling for Smart Home Energy Management

    Science.gov (United States)

    Silva, Bhagya Nathali; Khan, Murad; Han, Kijun

    2018-01-01

    The emergence of smart devices and smart appliances has highly favored the realization of the smart home concept. Modern smart home systems handle a wide range of user requirements. Energy management and energy conservation are in the spotlight when deploying sophisticated smart homes. However, the performance of energy management systems is highly influenced by user behaviors and adopted energy management approaches. Appliance scheduling is widely accepted as an effective mechanism to manage domestic energy consumption. Hence, we propose a smart home energy management system that reduces unnecessary energy consumption by integrating an automated switching off system with load balancing and appliance scheduling algorithm. The load balancing scheme acts according to defined constraints such that the cumulative energy consumption of the household is managed below the defined maximum threshold. The scheduling of appliances adheres to the least slack time (LST) algorithm while considering user comfort during scheduling. The performance of the proposed scheme has been evaluated against an existing energy management scheme through computer simulation. The simulation results have revealed a significant improvement gained through the proposed LST-based energy management scheme in terms of cost of energy, along with reduced domestic energy consumption facilitated by an automated switching off mechanism. PMID:29495346

  14. Load Balancing Integrated Least Slack Time-Based Appliance Scheduling for Smart Home Energy Management

    Directory of Open Access Journals (Sweden)

    Bhagya Nathali Silva

    2018-02-01

    Full Text Available The emergence of smart devices and smart appliances has highly favored the realization of the smart home concept. Modern smart home systems handle a wide range of user requirements. Energy management and energy conservation are in the spotlight when deploying sophisticated smart homes. However, the performance of energy management systems is highly influenced by user behaviors and adopted energy management approaches. Appliance scheduling is widely accepted as an effective mechanism to manage domestic energy consumption. Hence, we propose a smart home energy management system that reduces unnecessary energy consumption by integrating an automated switching off system with load balancing and appliance scheduling algorithm. The load balancing scheme acts according to defined constraints such that the cumulative energy consumption of the household is managed below the defined maximum threshold. The scheduling of appliances adheres to the least slack time (LST algorithm while considering user comfort during scheduling. The performance of the proposed scheme has been evaluated against an existing energy management scheme through computer simulation. The simulation results have revealed a significant improvement gained through the proposed LST-based energy management scheme in terms of cost of energy, along with reduced domestic energy consumption facilitated by an automated switching off mechanism.

  15. Load Balancing Integrated Least Slack Time-Based Appliance Scheduling for Smart Home Energy Management.

    Science.gov (United States)

    Silva, Bhagya Nathali; Khan, Murad; Han, Kijun

    2018-02-25

    The emergence of smart devices and smart appliances has highly favored the realization of the smart home concept. Modern smart home systems handle a wide range of user requirements. Energy management and energy conservation are in the spotlight when deploying sophisticated smart homes. However, the performance of energy management systems is highly influenced by user behaviors and adopted energy management approaches. Appliance scheduling is widely accepted as an effective mechanism to manage domestic energy consumption. Hence, we propose a smart home energy management system that reduces unnecessary energy consumption by integrating an automated switching off system with load balancing and appliance scheduling algorithm. The load balancing scheme acts according to defined constraints such that the cumulative energy consumption of the household is managed below the defined maximum threshold. The scheduling of appliances adheres to the least slack time (LST) algorithm while considering user comfort during scheduling. The performance of the proposed scheme has been evaluated against an existing energy management scheme through computer simulation. The simulation results have revealed a significant improvement gained through the proposed LST-based energy management scheme in terms of cost of energy, along with reduced domestic energy consumption facilitated by an automated switching off mechanism.

  16. Effects of bud loading levels and nitrogen doses on yield, physical ...

    African Journals Online (AJOL)

    The aim of this study was to investigate the effects of several bud loading levels in winter pruning and nitrogen doses on yield and physical and chemical properties of fresh vine-leaves of grape cultivar “Narince”. Vines trained with bilateral cordon system was pruned to yield 35000 to 53000 buds/ha (16 or 24 buds/vine) ...

  17. Using Cognitive Load Theory to Tailor Instruction to Levels of Accounting Students' Expertise

    Science.gov (United States)

    Blayney, Paul; Kalyuga, Slava; Sweller, John

    2015-01-01

    Tailoring of instructional methods to learner levels of expertise may reduce extraneous cognitive load and improve learning. Contemporary technology-based learning environments have the potential to substantially enable learner-adapted instruction. This paper investigates the effects of adaptive instruction based on using the isolated-interactive…

  18. Real - time Optimization of Distributed Energy Storage System Operation Strategy Based on Peak Load Shifting

    Science.gov (United States)

    Wang, Qian; Lu, Guangqi; Li, Xiaoyu; Zhang, Yichi; Yun, Zejian; Bian, Di

    2018-01-01

    To take advantage of the energy storage system (ESS) sufficiently, the factors that the service life of the distributed energy storage system (DESS) and the load should be considered when establishing optimization model. To reduce the complexity of the load shifting of DESS in the solution procedure, the loss coefficient and the equal capacity ratio distribution principle were adopted in this paper. Firstly, the model was established considering the constraint conditions of the cycles, depth, power of the charge-discharge of the ESS, the typical daily load curves, as well. Then, dynamic programming method was used to real-time solve the model in which the difference of power Δs, the real-time revised energy storage capacity Sk and the permission error of depth of charge-discharge were introduced to optimize the solution process. The simulation results show that the optimized results was achieved when the load shifting in the load variance was not considered which means the charge-discharge of the energy storage system was not executed. In the meantime, the service life of the ESS would increase.

  19. Simple Levelized Cost of Energy (LCOE) Calculator Documentation | Energy

    Science.gov (United States)

    ;M, performance and fuel costs. Note that this doesn't include financing issues, discount issues ). This means that the LCOE is the minimum price at which energy must be sold for an energy project to the balance between debt-financing and equity-financing, and an assessment of the financial risk

  20. Coordinated control of distributed energy resources to support load frequency control

    International Nuclear Information System (INIS)

    Ravikumar Pandi, V.; Al-Hinai, A.; Feliachi, Ali

    2015-01-01

    Highlights: • We aims to maintain feeder power flow by the coordination of DER units. • The error in feeder flow with respect to scheduled value is used by the controller. • The particle swarm optimization is employed to minimize the error in feeder flow. • Implemented on a transmission system along with 37 bus distribution feeder. • The results of proposed feeder control is analyzed with no feeder control scheme. - Abstract: The control of generating resources to follow the unscheduled load changes is considered to be an essential process in the power system in order to maintain the frequency of power supply. This load frequency control (LFC) problem has been given more importance in the recent smart grid environment because of the impact from high penetration of distributed energy resources (DER) installed at the distribution level. The renewable sources are highly intermittent in nature, so it is required to coordinate and control the DER units to maintain the feeder power flow at substation bus bar which is seen by transmission system operator during the LFC process. This paper aims to identify the impact of distributed generation and its control method to reduce the deviation of feeder power flow from the scheduled value in real time operation. The error in feeder power flow with respect to scheduled value is utilized by the PI controller to estimate the change in power reference of all DER units. The power output of DER units are maintained to reference values by the individual PI controllers. The particle swarm optimization algorithm is employed to minimize the error in feeder power flow by optimally tuning the gain values of all PI controllers. The proposed method is examined on a small transmission system along with the feeder of IEEE 37 bus distribution system with balanced loading condition. The complete system along with DER units is implemented in the MATLAB based stability package named Power Analysis Toolbox (PAT) for performing time domain

  1. Energy Evolution Mechanism and Confining Pressure Effect of Granite under Triaxial Loading-Unloading Cycles

    Science.gov (United States)

    Wang, Hao; Miao, Sheng-jun

    2018-05-01

    Rock mass undergoes some deformational failure under the action of external loads, a process known to be associated with energy dissipation and release. A triaxial loading-unloading cycle test was conducted on granite in order to investigate the energy evolution pattern of rock mass under the action of external loads. The study results demonstrated: (1) The stress peaks increased by 50% and 22% respectively and the pre-peak weakening became more apparent in the ascending process of the confining pressure from 10MPa to 30MPa; the area enclosed by the hysteresis loop corresponding to 30MPa diminished by nearly 60% than that corresponding to 10MPa, indicating a higher confining pressure prohibits rock mass from plastic deformation and shifts strain toward elastic deformation. (2) In the vicinity of the strength limit, the slope of dissipation energy increased to 1.6 from the original 0.7 and the dissipation energy grew at an accelerating rate, demonstrating stronger propagation and convergence of internal cracks. (3) At a pressure of 70% of the stress peak, the elastic energy of the granite accounted for 88% of its peak value, suggesting the rock mechanical energy from the outside mostly changes into the elastic energy inside the rock, with little energy loss.(4) Prior to test specimen failure, the axial bearing capacity dropped with a decreasing confining pressure in an essentially linear way, and the existence of confirming pressure played a role in stabilizing the axial bearing capacity.

  2. Mobility-Aware and Load Balancing Based Clustering Algorithm for Energy Conservation in MANET

    Institute of Scientific and Technical Information of China (English)

    XU Li; ZHENG Bao-yu; GUO Gong-de

    2005-01-01

    Mobile ad hoc network (MANET) is one of wireless communication network architecture that has received a lot of attention. MANET is characterized by dynamic network topology and limited energy. With mobility-aware and load balancing based clustering algorithm (MLCA), this paper proposes a new topology management strategy to conserve energy. Performance simulation results show that the proposed MLCA strategy can balances the traffic load inside the whole network, so as to prolong the network lifetime, meanly, at the same time, achieve higher throughput ratio and network stability.

  3. Creep behavior of sweetgum OSB: effect of load level and relative humidity

    Science.gov (United States)

    J.H. Pu; R.C. Tang; Chung-Yun Hse

    1994-01-01

    Flexural creep behavior of laboratory-fabricated sweetgum oriented strandboard (OSB). under constnat (65% and 95%) and cyclic (65% 95% at a 96-hr. frequency) relative humidity (RH) conditions at 75 F (23.9 C) is presented. Two levels (4.5% and 6.5%) of resin content (RC) of phenol-formaldehyde were used in fabricating the test panels. Two load levels (20% and...

  4. Experimental study on the wave loads on a rotor of the WEPTOS Wave Energy Converter

    DEFF Research Database (Denmark)

    Pecher, Arthur; Kofoed, Jens Peter

    Experimental tests have been performed to investigate the wave load on the rotor in design wave conditions. These wave loads should give an indication of the required structural strength around the rotors as well as for other equipment such as the bearings. During the lab tests, the wave loads have...... been measured for the following configurations: • Head and beam seas (wave coming from the front and the side) • For three different submergence levels • For three different dispositions of the rotor (free to rotate, and fixed at 50° and 90°) Based on this results, an estimation of the maximum wave...... loads has been made on the maximum wave loads at the DanWEC test site....

  5. Research on the Operation Mode of Intelligent-town Energy Internet Based on Source-Load Interaction

    Science.gov (United States)

    Li, Hao; Li, Wen; Miao, Bo; Li, Bin; Liu, Chang; Lv, Zhipeng

    2018-01-01

    On the background of the rise of intelligence and the increasing deepening of “Internet +”application, the energy internet has become the focus of the energy research field. This paper, based on the fundamental understanding on the energy internet of the intelligent town, discusses the mode of energy supply in the source-load interactive region, and gives an in-depth study on the output characteristics of the energy supply side and the load characteristics of the demand side, so as to derive the law of energy-load interaction of the intelligent-town energy internet.

  6. Fatigue Crack Propagation Under Variable Amplitude Loading Analyses Based on Plastic Energy Approach

    Directory of Open Access Journals (Sweden)

    Sofiane Maachou

    2014-04-01

    Full Text Available Plasticity effects at the crack tip had been recognized as “motor” of crack propagation, the growth of cracks is related to the existence of a crack tip plastic zone, whose formation and intensification is accompanied by energy dissipation. In the actual state of knowledge fatigue crack propagation is modeled using crack closure concept. The fatigue crack growth behavior under constant amplitude and variable amplitude loading of the aluminum alloy 2024 T351 are analyzed using in terms energy parameters. In the case of VAL (variable amplitude loading tests, the evolution of the hysteretic energy dissipated per block is shown similar with that observed under constant amplitude loading. A linear relationship between the crack growth rate and the hysteretic energy dissipated per block is obtained at high growth rates. For lower growth rates values, the relationship between crack growth rate and hysteretic energy dissipated per block can represented by a power law. In this paper, an analysis of fatigue crack propagation under variable amplitude loading based on energetic approach is proposed.

  7. Wind Energy Management System EMS Integration Project: Incorporating Wind Generation and Load Forecast Uncertainties into Power Grid Operations

    Energy Technology Data Exchange (ETDEWEB)

    Makarov, Yuri V.; Huang, Zhenyu; Etingov, Pavel V.; Ma, Jian; Guttromson, Ross T.; Subbarao, Krishnappa; Chakrabarti, Bhujanga B.

    2010-01-01

    The power system balancing process, which includes the scheduling, real time dispatch (load following) and regulation processes, is traditionally based on deterministic models. Since the conventional generation needs time to be committed and dispatched to a desired megawatt level, the scheduling and load following processes use load and wind and solar power production forecasts to achieve future balance between the conventional generation and energy storage on the one side, and system load, intermittent resources (such as wind and solar generation), and scheduled interchange on the other side. Although in real life the forecasting procedures imply some uncertainty around the load and wind/solar forecasts (caused by forecast errors), only their mean values are actually used in the generation dispatch and commitment procedures. Since the actual load and intermittent generation can deviate from their forecasts, it becomes increasingly unclear (especially, with the increasing penetration of renewable resources) whether the system would be actually able to meet the conventional generation requirements within the look-ahead horizon, what the additional balancing efforts would be needed as we get closer to the real time, and what additional costs would be incurred by those needs. To improve the system control performance characteristics, maintain system reliability, and minimize expenses related to the system balancing functions, it becomes necessary to incorporate the predicted uncertainty ranges into the scheduling, load following, and, in some extent, into the regulation processes. It is also important to address the uncertainty problem comprehensively by including all sources of uncertainty (load, intermittent generation, generators’ forced outages, etc.) into consideration. All aspects of uncertainty such as the imbalance size (which is the same as capacity needed to mitigate the imbalance) and generation ramping requirement must be taken into account. The latter

  8. A multi-objective genetic approach to domestic load scheduling in an energy management system

    International Nuclear Information System (INIS)

    Soares, Ana; Antunes, Carlos Henggeler; Oliveira, Carlos; Gomes, Álvaro

    2014-01-01

    In this paper a multi-objective genetic algorithm is used to solve a multi-objective model to optimize the time allocation of domestic loads within a planning period of 36 h, in a smart grid context. The management of controllable domestic loads is aimed at minimizing the electricity bill and the end-user’s dissatisfaction concerning two different aspects: the preferred time slots for load operation and the risk of interruption of the energy supply. The genetic algorithm is similar to the Elitist NSGA-II (Nondominated Sorting Genetic Algorithm II), in which some changes have been introduced to adapt it to the physical characteristics of the load scheduling problem and improve usability of results. The mathematical model explicitly considers economical, technical, quality of service and comfort aspects. Illustrative results are presented and the characteristics of different solutions are analyzed. - Highlights: • A genetic algorithm similar to the NSGA-II is used to solve a multi-objective model. • The optimized time allocation of domestic loads in a smart grid context is achieved. • A variable preference profile for the operation of the managed loads is included. • A safety margin is used to account for the quality of the energy services provided. • A non-dominated front with the solutions in the two-objective space is obtained

  9. Matching renewable energy systems to village-level energy needs

    Energy Technology Data Exchange (ETDEWEB)

    Ashworth, J.H.; Neuendorffer, J.W.

    1980-06-01

    This report provides a five step process for matching alternative renewable energy technologies with energy needs in rural villages of developing countries. Analytic tools are given for each of the five steps as well as information that can be expected. Twelve characterization criteria are developed to assist in the matching process. Three of these criteria, called discrimination criteria, are used for preliminary screening of technology possibilities for each need. The other criteria address site-specific temporal, climatic, social, cultural, and environmental characteristics of the energy need, technology, and cost considerations. To illustrate the matching process, seven basic human needs for energy are matched with seven potential renewable energy technologies. The final portion of the paper discusses the advantages of such a matching process and the resources required to initiate such an effort within a development project. Specific recommendations are given for field-testing this process and actions that could be taken immediately in basic research and development, applied research and technology modification, demonstrations, and commercialization to assist in the future diffusion of renewable energy technologies to rural areas of developing countries.

  10. Calculation approaches for grid usage fees to influence the load curve in the distribution grid level; Berechnungsansaetze fuer Netznutzungsentgelte zur Beeinflussung des Lastverlaufs in der Verteilernetzebene

    Energy Technology Data Exchange (ETDEWEB)

    Illing, Bjoern

    2014-09-08

    Dominated by the energy policy the decentralized German energy market is changing. One mature target of the government is to increase the contribution of renewable generation to the gross electricity consumption. In order to achieve this target disadvantages like an increased need for capacity management occurs. Load reduction and variable grid fees offer the grid operator solutions to realize capacity management by influencing the load profile. The evolution of the current grid fees towards more causality is required to adapt these approaches. Two calculation approaches are developed in this assignment. On the one hand multivariable grid fees keeping the current components demand and energy charge. Additional to the grid costs grid load dependent parameters like the amount of decentralized feed-ins, time and local circumstances as well as grid capacities are considered. On the other hand the grid fee flat-rate which represents a demand based model on a monthly level. Both approaches are designed to meet the criteria for future grid fees. By means of a case study the effects of the grid fees on the load profile at the low voltage grid is simulated. Thereby the consumption is represented by different behaviour models and the results are scaled at the benchmark grid area. The resulting load curve is analyzed concerning the effects of peak load reduction as well as the integration of renewable energy sources. Additionally the combined effect of grid fees and electricity tariffs is evaluated. Finally the work discusses the launching of grid fees in the tense atmosphere of politics, legislation and grid operation. Results of this work are two calculation approaches designed for grid operators to define the grid fees. Multivariable grid fees are based on the current calculation scheme. Hereby demand and energy charges are weighted by time, locational and load related dependencies. The grid fee flat-rate defines a limitation in demand extraction. Different demand levels

  11. Rat disc torsional mechanics: effect of lumbar and caudal levels and axial compression load.

    Science.gov (United States)

    Espinoza Orías, Alejandro A; Malhotra, Neil R; Elliott, Dawn M

    2009-03-01

    Rat models with altered loading are used to study disc degeneration and mechano-transduction. Given the prominent role of mechanics in disc function and degeneration, it is critical to measure mechanical behavior to evaluate changes after model interventions. Axial compression mechanics of the rat disc are representative of the human disc when normalized by geometry, and differences between the lumbar and caudal disc have been quantified in axial compression. No study has quantified rat disc torsional mechanics. Compare the torsional mechanical behavior of rat lumbar and caudal discs, determine the contribution of combined axial load on torsional mechanics, and compare the torsional properties of rat discs to human lumbar discs. Cadaveric biomechanical study. Cyclic torsion without compressive load followed by cyclic torsion with a fixed compressive load was applied to rat lumbar and caudal disc levels. The apparent torsional modulus was higher in the lumbar region than in the caudal region: 0.081+/-0.026 (MPa/degrees, mean+/-SD) for lumbar axially loaded; 0.066+/-0.028 for caudal axially loaded; 0.091+/-0.033 for lumbar in pure torsion; and 0.056+/-0.035 for caudal in pure torsion. These values were similar to human disc properties reported in the literature ranging from 0.024 to 0.21 MPa/degrees. Use of the caudal disc as a model may be appropriate if the mechanical focus is within the linear region of the loading regime. These results provide support for use of this animal model in basic science studies with respect to torsional mechanics.

  12. Implementation and Assessment of a Decentralized Load Frequency Control: Application to Power Systems with High Wind Energy Penetration

    Directory of Open Access Journals (Sweden)

    Irene Muñoz-Benavente

    2017-01-01

    Full Text Available This paper describes and assesses a decentralized solution based on a wireless sensor-actuator network to provide primary frequency control from demand response in power systems with high wind energy penetration and, subsequently, with relevant frequency excursions. The proposed system is able to modify the electrical power demand of a variety of thermostatically-controlled loads, maintaining minimum comfort levels and minimizing both infrastructure requirements and primary reserves from the supply side. This low-cost hardware solution avoids any additional wiring, extending the wireless sensor-actuator network technology towards small customers, which account for over a 30% share of the current power demand. Frequency excursions are collected by each individual load controller, considering not only the magnitude of the frequency deviation, but also their evolution over time. Based on these time-frequency excursion characteristics, controllers are capable of modifying the power consumption of thermostatically-controlled loads by switching them off and on, thus contributing to primary frequency control in power systems with higher generation unit oscillations as a consequence of relevant wind power integration. Field tests have been carried out in a laboratory environment to assess the load controller performance, as well as to evaluate the electrical and thermal response of individual loads under frequency deviations. These frequency deviations are estimated from power systems with a high penetration of wind energy, which are more sensitive to frequency oscillations and where demand response can significantly contribute to mitigate these frequency excursions. The results, also included in the paper, evaluate the suitability of the proposed load controllers and their suitability to decrease frequency excursions from the demand side in a decentralized manner.

  13. Estimating Solar Energy Potential in Buildings on a Global Level

    DEFF Research Database (Denmark)

    Petrichenko, Ksenia

    2015-01-01

    This chapter contributes to the debate around net-zero energy concept from a global perspective. By means of comprehensive modelling, it analyses how much global building energy consumption could be reduced through utilisation of building-integrated solar energy technologies and energy......-efficiency improvements. Valuable insights on the locations and building types, in which it is feasible to achieve a net-zero level of energy performance through solar energy utilisation, are presented in world maps....

  14. Nuclear energy levels and elementary particles

    International Nuclear Information System (INIS)

    de Wet, J.A.

    1982-01-01

    Considering only exchange forces, the binding energies and excited states of nuclei up to 24 Mg are predicted to within charge independence, and there is no reason why the model should not be extended to cover all of the elements. A comparison of theory with experiment shows that the energy of one exchange is 2.56 MeV. Moreover, there is an attractive well of depth 30 MeV, corresponding to the helium nucleus. before exchange forces become operative. A possible explanation of the origin of mesons is also presented

  15. Towards smart energy systems: application of kernel machine regression for medium term electricity load forecasting.

    Science.gov (United States)

    Alamaniotis, Miltiadis; Bargiotas, Dimitrios; Tsoukalas, Lefteri H

    2016-01-01

    Integration of energy systems with information technologies has facilitated the realization of smart energy systems that utilize information to optimize system operation. To that end, crucial in optimizing energy system operation is the accurate, ahead-of-time forecasting of load demand. In particular, load forecasting allows planning of system expansion, and decision making for enhancing system safety and reliability. In this paper, the application of two types of kernel machines for medium term load forecasting (MTLF) is presented and their performance is recorded based on a set of historical electricity load demand data. The two kernel machine models and more specifically Gaussian process regression (GPR) and relevance vector regression (RVR) are utilized for making predictions over future load demand. Both models, i.e., GPR and RVR, are equipped with a Gaussian kernel and are tested on daily predictions for a 30-day-ahead horizon taken from the New England Area. Furthermore, their performance is compared to the ARMA(2,2) model with respect to mean average percentage error and squared correlation coefficient. Results demonstrate the superiority of RVR over the other forecasting models in performing MTLF.

  16. Short-Term Load Forecast in Electric Energy System in Bulgaria

    Directory of Open Access Journals (Sweden)

    Irina Asenova

    2010-01-01

    Full Text Available As the accuracy of the electricity load forecast is crucial in providing better cost effective risk management plans, this paper proposes a Short Term Electricity Load Forecast (STLF model with high forecasting accuracy. Two kind of neural networks, Multilayer Perceptron network model and Radial Basis Function network model, are presented and compared using the mean absolute percentage error. The data used in the models are electricity load historical data. Even though the very good performance of the used model for the load data, weather parameters, especially the temperature, take important part for the energy predicting which is taken into account in this paper. A comparative evaluation between a traditional statistical method and artificial neural networks is presented.

  17. Coordinated Optimization of Distributed Energy Resources and Smart Loads in Distribution Systems: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Rui; Zhang, Yingchen

    2016-08-01

    Distributed energy resources (DERs) and smart loads have the potential to provide flexibility to the distribution system operation. A coordinated optimization approach is proposed in this paper to actively manage DERs and smart loads in distribution systems to achieve the optimal operation status. A three-phase unbalanced Optimal Power Flow (OPF) problem is developed to determine the output from DERs and smart loads with respect to the system operator's control objective. This paper focuses on coordinating PV systems and smart loads to improve the overall voltage profile in distribution systems. Simulations have been carried out in a 12-bus distribution feeder and results illustrate the superior control performance of the proposed approach.

  18. Control and design of full-bridge three-level converter for renewable energy sources

    DEFF Research Database (Denmark)

    Yao, Zhilei; Xu, Jing; Guerrero, Josep M.

    2015-01-01

    Output voltage of renewable energy sources, such as fuel cell and PV cell, is often low and varies widely with load and environmental conditions. Therefore, the high step-up DC-DC converter is needed between renewable energy sources and the grid-connected inverter. However, voltage stress...... of rectifier diodes is high and filter is large in traditional voltage-source converters in a wide input-voltage range. In order to solve the aforementioned problems, a full-bridge (FB) three-level (TL) converter is proposed. It can operate at both two-level and three-level modes, so it is suitable for wide...

  19. Cost optimal levels for energy performance requirements

    DEFF Research Database (Denmark)

    Thomsen, Kirsten Engelund; Aggerholm, Søren; Kluttig-Erhorn, Heike

    This report summarises the work done within the Concerted Action EPBD from December 2010 to April 2011 in order to feed into the European Commission's proposal for a common European procedure for a Cost-Optimal methodology under the Directive on the Energy Performance of Buildings (recast) 2010/3...

  20. BK Virus Load Associated with Serum Levels of sCD30 in Renal Transplant Recipients

    Science.gov (United States)

    Malik, Salma N.; Al-Saffer, Jinan M.; Jawad, Rana S.

    2016-01-01

    Background. Rejection is the main drawback facing the renal transplant operations. Complicated and overlapping factors, mainly related to the immune system, are responsible for this rejection. Elevated serum levels of sCD30 were frequently recorded as an indicator for renal allograft rejection, while BV virus is considered as one of the most serious consequences for immunosuppressive treatment of renal transplant recipients (RTRs). Aims. This study aimed to determine the association of BK virus load with serum levels of sCD30 in RTRs suffering from nephropathy. Patients and Methods. A total of 50 RTRs with nephropathy and 30 age-matched apparently healthy individuals were recruited for this study. Serum samples were obtained from each participant. Real-time PCR was used to quantify BK virus load in RTRs serum, while ELISA technique was employed to estimate serum levels of sCD30. Results. Twenty-two percent of RTRs had detectable BKV with mean viral load of 1.094E + 06 ± 2.291E + 06. RTRs showed higher mean serum level of sCD30 (20.669 ± 18.713 U/mL) than that of controls (5.517 ± 5.304 U/mL) with significant difference. BK virus load had significant positive correlation with the serum levels of sCD30 in RTRs group. Conclusion. These results suggest that serum levels of sCD30 could be used as an indicator of BK viremia, and accordingly the immunosuppressive regime should be adjusted. PMID:27051424

  1. Linear active disturbance rejection-based load frequency control concerning high penetration of wind energy

    International Nuclear Information System (INIS)

    Tang, Yanmei; Bai, Yan; Huang, Congzhi; Du, Bin

    2015-01-01

    Highlights: • A disturbance rejection solution to the load frequency control issue is proposed. • Several power systems with wind energy conversation system have been tested. • A tuning algorithm of the controller parameters was proposed. • The performance of the proposed approach is better than traditional controllers. - Abstract: A new grid load frequency control approach is proposed for the doubly fed induction generator based wind power plants. The load frequency control issue in a power system is undergoing fundamental changes due to the rapidly growing amount of wind energy conversation system, and concentrating on maintaining generation-load balance and disturbance rejection. The prominent feature of the linear active disturbance rejection control approach is that the total disturbance can be estimated and then eliminated in real time. And thus, it is a feasible solution to deal with the load frequency control issue. In this paper, the application of the linear active disturbance rejection control approach in the load frequency control issue for a complex power system with wind energy conversation system based on doubly fed induction generator is investigated. The load frequency control issue is formulated as a decentralized multi-objective optimization control problem, the solution to which is solved by the hybrid particle swarm optimization technique. To show the effectiveness of the proposed control scheme, the robust performance testing based on Monte-Carlo approach is carried out. The performance superiority of the system with the proposed linear active disturbance rejection control approach over that with the traditional proportional integral and fuzzy-proportional integral-based controllers is validated by the simulation results

  2. Determination of the wind power systems load to achieve operation in the maximum energy area

    Science.gov (United States)

    Chioncel, C. P.; Tirian, G. O.; Spunei, E.; Gillich, N.

    2018-01-01

    This paper analyses the operation of the wind turbine, WT, in the maximum power point, MPP, by linking the load of the Permanent Magnet Synchronous Generator, PMSG, with the wind speed value. The load control methods at wind power systems aiming an optimum performance in terms of energy are based on the fact that the energy captured by the wind turbine significantly depends on the mechanical angular speed of the wind turbine. The presented control method consists in determining the optimal mechanical angular speed, ωOPTIM, using an auxiliary low power wind turbine, WTAUX, operating without load, at maximum angular velocity, ωMAX. The method relies on the fact that the ratio ωOPTIM/ωMAX has a constant value for a given wind turbine and does not depend on the time variation of the wind speed values.

  3. Experimental study of plasma energy transfer and material erosion under ELM-like heat loads

    Energy Technology Data Exchange (ETDEWEB)

    Garkusha, I.E., E-mail: garkusha@ipp.kharkov.u [Institute of Plasma Physics of the NSC KIPT, Akademicheskaya 1, 61108 Kharkov (Ukraine); Makhlaj, V.A.; Chebotarev, V.V. [Institute of Plasma Physics of the NSC KIPT, Akademicheskaya 1, 61108 Kharkov (Ukraine); Landman, I. [Forschungszentrum Karlsruhe, IHM, 76021 Karlsruhe (Germany); Tereshin, V.I.; Aksenov, N.N.; Bandura, A.N. [Institute of Plasma Physics of the NSC KIPT, Akademicheskaya 1, 61108 Kharkov (Ukraine)

    2009-06-15

    Main features of plasma-surface interaction and energy transfer to tokamak plasma facing components are studied at different heat loads in ELM simulation experiments with the plasma gun QSPA Kh-50. Repetitive plasma exposures of tungsten, graphite and different combined W-C targets were performed at the pulse duration of 0.25 ms and the heat loads varied in the range 0.2-2.5 MJ/m{sup 2}. The onset of vapor shield in front of the surface was investigated. The evaporation is immediately followed by a saturation of surface heat load if further increasing the impact energy. The presence of graphite essentially decreases the heat flux to the nearby tungsten surface, which is due to the carbon vapor shield. Droplet splashing at the tungsten surface and formation of hot spots on the graphite surface are discussed.

  4. Experimental study of plasma energy transfer and material erosion under ELM-like heat loads

    International Nuclear Information System (INIS)

    Garkusha, I.E.; Makhlaj, V.A.; Chebotarev, V.V.; Landman, I.; Tereshin, V.I.; Aksenov, N.N.; Bandura, A.N.

    2009-01-01

    Main features of plasma-surface interaction and energy transfer to tokamak plasma facing components are studied at different heat loads in ELM simulation experiments with the plasma gun QSPA Kh-50. Repetitive plasma exposures of tungsten, graphite and different combined W-C targets were performed at the pulse duration of 0.25 ms and the heat loads varied in the range 0.2-2.5 MJ/m 2 . The onset of vapor shield in front of the surface was investigated. The evaporation is immediately followed by a saturation of surface heat load if further increasing the impact energy. The presence of graphite essentially decreases the heat flux to the nearby tungsten surface, which is due to the carbon vapor shield. Droplet splashing at the tungsten surface and formation of hot spots on the graphite surface are discussed.

  5. Cognitive load privileges memory-based over data-driven processing, not group-level over person-level processing.

    Science.gov (United States)

    Skorich, Daniel P; Mavor, Kenneth I

    2013-09-01

    In the current paper, we argue that categorization and individuation, as traditionally discussed and as experimentally operationalized, are defined in terms of two confounded underlying dimensions: a person/group dimension and a memory-based/data-driven dimension. In a series of three experiments, we unconfound these dimensions and impose a cognitive load. Across the three experiments, two with laboratory-created targets and one with participants' friends as the target, we demonstrate that cognitive load privileges memory-based over data-driven processing, not group- over person-level processing. We discuss the results in terms of their implications for conceptualizations of the categorization/individuation distinction, for the equivalence of person and group processes, for the ultimate 'purpose' and meaningfulness of group-based perception and, fundamentally, for the process of categorization, broadly defined. © 2012 The British Psychological Society.

  6. Importance of nuclear station load factor in applied ro energy policies

    International Nuclear Information System (INIS)

    Gomes, Daniel de Souza

    2015-01-01

    Load factor is the ration between the energy produced by a station and the energy it would have produced running at maximum power. The factor intends for all types of commercial reactors. Nuclear plants continuously provide over 11% of the world's electricity. The reactors for which data were available generated 618.7 TWh of electricity in 2014. Typical load factor was around 75% in worldwide during the first quarter of 2015. In this manner, it obtained from an average, three-monthly or yearly. The regular load factor of the reactors in operation was around 56% in 1970. While, in 1980's decade, we have an increase to 63%, the same situation occurred in next the decade and suffering increasing to 73%. Currently, the load factor reaches 78%. Accidents are seasonal factors, with the occurrence of reduction of power generation plants. In 2015 in January, there are over 437 operable commercial reactors in 31 countries, with over 377,728 MWe of full capacity. In Brazil, total capacity is 1901 MWe, with around 2.8% of electricity energy consumed. The primary objective of this study was to find a forecast model that express the evolution of the load factor in the next years. In recent years occur an extensive development of pressurized water reactors in Asia. The periodicity of seasonal effects on the performance of nuclear power plants due to aging. However, the impact of plant age depended on new technologies that allow the growth of the performance. The accident of Fukushima was an inflection point for energy policies. The event produced a trend that reduced the load in the world. (author)

  7. Development of load calculation techniques on screw and screw press energy consumption

    OpenAIRE

    Татарьянц, Максим Сергеевич; Завинский, Сергей Иванович; Трошин, Алексей Георгиевич

    2015-01-01

    The process of pressing of wood chips in screw machines is researched. It is defined processes taking place in different parts of the screw, formulas allowing to calculate the loads acting on the screw flights, as well as to determine the power required for compression. The unit costs of energy consumption and raw materials in the degree of heat pressing are determined

  8. Wave loadings acting on innovative rubble mound breakwater for overtopping wave energy conversion

    DEFF Research Database (Denmark)

    Contestabile, Pasquale; Iuppa, Claudio; Lauro, Enrico Di

    2017-01-01

    Highlights •An innovative breakwater for overtopping wave energy conversion has been studied. •Physical model tests have been carried out and analysed. •Breakwater design information on loadings acting on various parts of the structure has been presented. •Design formulae and validation of some t...

  9. Integrated biomass and solar town: Incorporation of load shifting and energy storage

    International Nuclear Information System (INIS)

    Hashim, Haslenda; Ho, Wai Shin; Lim, Jeng Shiun; Macchietto, Sandro

    2014-01-01

    The IBS (Integrated Biomass Solar) town is a concept which encourages local community to utilize biomass waste comprehensively with strong ties between community and local stakeholders. This paper discusses an IBS model and solution for an electrically self-sufficient eco-village with and without LS (load shifting). ES (energy storage) is also incorporated to help reduce electricity demand during peak periods and smooth variations in power generation by variable generation of solar power. Application to a realistic case study shows that substantial technical and economic benefits are achieved through the implementation of IBS with LS and ES. In this study, the LS is used mainly to increase demand during periods of high supply and also shift the load to intervals with low demand. This reduces the size of ES significantly, where the load is subject to distinct weekday and weekend profiles. The study shows that highly competitive electricity prices are obtained and the concept offers the opportunity to spur economic growth and environmental protection through energy efficiency improvement and deployment of low-carbon technologies. - Highlights: • A hybrid energy system for designing and optimizing RE resource utilization. • The load shifting and energy storage are incorporated. • The proposed model is demonstrated on an Iskandar Malaysia case study. • The optimal power generation scheme and power generation schedule are determined

  10. Multi-Class load balancing scheme for QoS and energy ...

    African Journals Online (AJOL)

    Multi-Class load balancing scheme for QoS and energy conservation in cloud computing. ... If you would like more information about how to print, save, and work with PDFs, Highwire Press provides a helpful Frequently Asked Questions about PDFs. Alternatively, you can download the PDF file directly to your computer, from ...

  11. Association of Parasite Load Levels in Amniotic Fluid With Clinical Outcome in Congenital Toxoplasmosis.

    Science.gov (United States)

    Yamamoto, Lidia; Targa, Lília S; Sumita, Laura M; Shimokawa, Paulo T; Rodrigues, Jonatas C; Kanunfre, Kelly A; Okay, Thelma S

    2017-08-01

    To correlate neonatal and infant clinical outcome with parasite load in amniotic fluid (AF). We conducted a retrospective cohort study of 122 children whose mothers had toxoplasmosis during pregnancy. The children were monitored from birth to 12 months old. Stored AF samples were obtained at maternal diagnosis and tested by quantitative polymerase chain reaction. Gestational age at maternal infection, quantitative polymerase chain reaction results, neonatal anti-Toxoplasma gondii immunoglobulin (Ig) M, and clinical outcome at 12 months were correlated. Maternal infection occurred in 18 of 122 (14.7%) and 104 of 122 (85.2%) women in the first and second trimesters, respectively. At birth, IgM was present in 107 of 122 (87.7%) neonates and 36 (29.5%) were symptomatic. Of these, half occurred in the first and the other half in the second trimester and 6 of 36 had severe infections (16.7% of symptomatic, 4.9% of total), all infected in the first trimester. Parasite load levels were highly variable (median 35 parasites/mL, range 2-30,473). Logistic regression correlated symptomatic infection with gestational age (odds ratio [OR] 0.47, CI 0.31-0.73) and parasite load (OR 2.04, CI 1.23-3.37), but not with positive IgM (OR 6.81, CI 0.86-53.9). Negative correlations were found between gestational age and parasite load (rs -0.780, CI -0.843 to -0.696), gestational age and symptoms (rs -0.664, CI -0.755 to -0.547), but not gestational age and IgM (rs -0.136, CI -0.311 to 0.048). Parasite load levels distributed by percentile showed that all symptomatic patients appeared from the 75th percentile and all severe infections from the 95th percentile. Load rankings showed doubled the OR for each 20 parasite/mL increment. Parasite load was associated with symptomatic infections (area under the curve 0.959, CI 0.908-0.987) as well as gestational age (area under the curve 0.918, CI 0.855-0.960) and both parameters combined (area under the curve 0.969, CI 0.920-0.992). Parasite load in

  12. Reducing Plug Loads in Office Spaces: Hawaii and Guam Energy Improvement Technology Demonstration Project

    Energy Technology Data Exchange (ETDEWEB)

    Sheppy, M. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Metzger, I. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Cutler, D. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Holland, G. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Hanada, A. [Naval Facilities Engineering Command, Washington, DC (United States)

    2014-01-01

    As part of its overall strategy to meet its energy goals, the Naval Facilities Engineering Command (NAVFAC) partnered with the Department of Energy's National Renewable Energy Laboratory (NREL) to rapidly demonstrate and deploy cost-effective renewable energy and energy efficiency technologies. This project was one of several demonstrations of new or underutilized commercial energy technologies. The common goal was to demonstrate and measure the performance and economic benefit of the system while monitoring any ancillary impacts to related standards of service and operation and maintenance (O&M) practices. In short, demonstrations at naval facilities simultaneously evaluate the benefits and compatibility of the technology with the U.S. Department of Defense (DOD) mission, and with NAVFAC's design, construction, operations, and maintenance practices, in particular. This project demonstrated the performance of commercially available advanced power strips (APSs) for plug load energy reductions in building A4 at Joint Base Pearl Harbor-Hickam (JBPHH), Hawaii.

  13. Development of an Energy-Savings Calculation Methodology for Residential Miscellaneous Electric Loads: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Hendron, R.; Eastment, M.

    2006-08-01

    In order to meet whole-house energy savings targets beyond 50% in residential buildings, it will be essential that new technologies and systems approaches be developed to address miscellaneous electric loads (MELs). These MELs are comprised of the small and diverse collection of energy-consuming devices found in homes, including what are commonly known as plug loads (televisions, stereos, microwaves), along with all hard-wired loads that do not fit into other major end-use categories (doorbells, security systems, garage door openers). MELs present special challenges because their purchase and operation are largely under the control of the occupants. If no steps are taken to address MELs, they can constitute 40-50% of the remaining source energy use in homes that achieve 60-70% whole-house energy savings, and this percentage is likely to increase in the future as home electronics become even more sophisticated and their use becomes more widespread. Building America (BA), a U.S. Department of Energy research program that targets 50% energy savings by 2015 and 90% savings by 2025, has begun to identify and develop advanced solutions that can reduce MELs.

  14. Energy security issues at household level in India

    International Nuclear Information System (INIS)

    Jain, Garima

    2010-01-01

    Energy security at the household level implies ensuring assured and regular supply of clean energy fuels at an affordable price for various household activities. Threat to physical availability of clean energy fuels for cooking and lighting is determined through various indicators such as dependence on traditional fuels and limited access to clean fuels. Energy insecurity translates into various adverse social impacts. Financial threat to energy security is indicated by expenses incurred on energy fuels and affordability of clean fuels. Households spend a major portion of their income on acquiring energy fuels; however, due to high price of clean fuels, they continue to depend on traditional and inefficient fuels. There is an urgent need to address factors that pose a threat to energy security at the household level. In this regard, measures taken by the government agencies and other institutions are also reviewed. The paper also suggests the regulatory and policy interventions required to address the energy security issues at the household level.

  15. Fine-structure energy levels, oscillator strengths and lifetimes

    Indian Academy of Sciences (India)

    We have done relativistic calculations for the evaluation of energy levels, oscillator strengths, transition probabilities and lifetimes for Cr VIII ion. Use has been made of configuration interaction technique by including Briet–Pauli approximation. The energies of various levels from the ground state to excited levels of 3s3p6, ...

  16. Impacts of Using Distributed Energy Resources to Reduce Peak Loads in Vermont

    Energy Technology Data Exchange (ETDEWEB)

    Ruth, Mark F. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Lunacek, Monte S. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Jones, Birk [Univ. of New Mexico, Albuquerque, NM (United States); Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-11-28

    To help the United States develop a modern electricity grid that provides reliable power from multiple resources as well as resiliency under extreme conditions, the U.S. Department of Energy (DOE) is leading the Grid Modernization Initiative (GMI) to help shape the future of the nation's grid. Under the GMI, DOE funded the Vermont Regional Initiative project to provide the technical support and analysis to utilities that need to mitigate possible impacts of increasing renewable generation required by statewide goals. Advanced control of distributed energy resources (DER) can both support higher penetrations of renewable energy by balancing controllable loads to wind and photovoltaic (PV) solar generation and reduce peak demand by shedding noncritical loads. This work focuses on the latter. This document reports on an experiment that evaluated and quantified the potential benefits and impacts of reducing the peak load through demand response (DR) using centrally controllable electric water heaters (EWHs) and batteries on two Green Mountain Power (GMP) feeders. The experiment simulated various hypothetical scenarios that varied the number of controllable EWHs, the amount of distributed PV systems, and the number of distributed residential batteries. The control schemes were designed with several objectives. For the first objective, the primary simulations focused on reducing the load during the independent system operator (ISO) peak when capacity charges were the primary concern. The second objective was to mitigate DR rebound to avoid new peak loads and high ramp rates. The final objective was to minimize customers' discomfort, which is defined by the lack of hot water when it is needed. We performed the simulations using the National Renewable Energy Laboratory's (NREL's) Integrated Energy System Model (IESM) because it can simulate both electric power distribution feeder and appliance end use performance and it includes the ability to simulate

  17. Load following generation in nuclear power plants by latent thermal energy storage

    International Nuclear Information System (INIS)

    Abe, Yoshiyuki; Takahashi, Yoshio; Kamimoto, Masayuki; Sakamoto, Ryuji; Kanari, Katsuhiko; Ozawa, Takeo

    1985-01-01

    The recent increase in nuclear power plants and the growing difference between peak and off-peak demands imperatively need load following generation in nuclear power plants to meet the time-variant demands. One possible way to resolve the problem is, obviously, a prompt reaction conrol in the reactors. Alternatively, energy storage gives another sophisticated path to make load following generation in more effective manner. Latent thermal energy storage enjoys high storage density and allows thermal extraction at nearly constant temperature, i.e. phase change temperature. The present report is an attempt to evaluate the feasibility of load following electric power generation in nuclear plants (actually Pressurized Water Reactors) by latent thermal energy storage. In this concept, the excess thermal energy in the off-peak period is stored in molten salt latent thermal energy storage unit, and additional power output is generated in auxiliary generator in the peak demand duration using the stored thermal energy. The present evaluation gives encouraging results and shows the primary subject to be taken up at first is the compatibility of candidate storage materials with inexpensive structural metal materials. Chapter 1 denotes the background of the present report, and Chapter 2 reviews the previous studies on the peak load coverage by thermal energy storage. To figure out the concept of the storage systems, present power plant systems and possible constitution of storage systems are briefly shown in Chapter 3. The details of the evaluation of the candidate storage media, and the compilation of the materials' properties are presented in Chapter 4. In Chapter 5, the concept of the storage systems is depicted, and the economical feasibility of the systems is evaluated. The concluding remarks are summarized in Chapter 6. (author)

  18. New energy level identifications in Kr VI

    International Nuclear Information System (INIS)

    Tauheed, A.; Pinnington, E.H.; Ansbacher, W.; Kernahan, J.A.

    1990-01-01

    Beam-foil delayed spectra from 89.0 to 101.0 nm are used to identify the intercombination lines connecting the 4s4p 2 4 P and 4s 2 4p 2 P levels in Kr VI. The existing analysis is extended to include the 4s 2 5s 2 S 1/2 , 4f 2 F 5/2 , 2 F 7/2 , 4p 3 2 D 3/2 , 2 D 5/2 , 2 P 3/2 , 4 S 3/2 and 4s4p 2 4 P 1/2 , 4 P 3/2 , 4 P 5/2 levels. Lifetime measurements for the 4s4p 2 4 P 1/2 , 4 P 5/2 , 4p 3 2 D 3/2 and 2 D 5/2 levels are also discussed in support of these assignments. (orig.)

  19. Decreased insulin clearance in individuals with elevated 1-h post-load plasma glucose levels.

    Directory of Open Access Journals (Sweden)

    Maria Adelaide Marini

    Full Text Available Reduced insulin clearance has been shown to predict the development of type 2 diabetes. Recently, it has been suggested that plasma glucose concentrations ≥ 8.6 mmol/l (155 mg/dl at 1 h during an oral glucose tolerance test (OGTT can identify individuals at high risk for type 2 diabetes among those who have normal glucose tolerance (NGT 1 h-high. The aim of this study was to examine whether NGT 1 h-high have a decrease in insulin clearance, as compared with NGT individuals with 1-h post-load glucose <8.6 mmol/l (l (155 mg/dl, NGT 1 h-low. To this end, 438 non-diabetic White individuals were subjected to OGTT and euglycemic-hyperinsulinemic clamp to evaluate insulin clearance and insulin sensitivity. As compared with NGT 1 h-low individuals, NGT 1 h-high had significantly higher 1-h and 2-h post-load plasma glucose and 2-h insulin levels as well as higher fasting glucose and insulin levels. NGT 1 h-high exhibited also a significant decrease in both insulin sensitivity (P<0.0001 and insulin clearance (P = 0.006 after adjusting for age, gender, adiposity measures, and insulin sensitivity. The differences in insulin clearance remained significant after adjustment for fasting glucose (P = 0.02 in addition to gender, age, and BMI. In univariate analyses adjusted for gender and age, insulin clearance was inversely correlated with body weight, body mass index, waist, fat mass, 1-h and 2-h post-load glucose levels, fasting, 1-h and 2-h post-load insulin levels, and insulin-stimulated glucose disposal. In conclusion, our data show that NGT 1 h-high have a reduction in insulin clearance as compared with NGT 1 h-low individuals; this suggests that impaired insulin clearance may contribute to sustained fasting and post-meal hyperinsulinemia.

  20. Eutrophic lichens respond to multiple forms of N: implications for critical levels and critical loads research

    Science.gov (United States)

    Sarah Jovan; Jennifer Riddell; Pamela E Padgett; Thomas Nash

    2012-01-01

    Epiphytic lichen communities are highly sensitive to excess nitrogen (N), which causes the replacement of native floras by N-tolerant, ‘‘weedy’’ eutrophic species. This shift is commonly used as the indicator of ecosystem ‘‘harm’’ in studies developing empirical critical levels (CLE) for ammonia (NH3) and critical loads (CLO) for N. To be most...

  1. Analytic model for ultrasound energy receivers and their optimal electric loads

    Science.gov (United States)

    Gorostiaga, M.; Wapler, M. C.; Wallrabe, U.

    2017-08-01

    In this paper, we present an analytic model for thickness resonating plate ultrasound energy receivers, which we have derived from the piezoelectric and the wave equations and, in which we have included dielectric, viscosity and acoustic attenuation losses. Afterwards, we explore the optimal electric load predictions by the zero reflection and power maximization approaches present in the literature with different acoustic boundary conditions, and discuss their limitations. To validate our model, we compared our expressions with the KLM model solved numerically with very good agreement. Finally, we discuss the differences between the zero reflection and power maximization optimal electric loads, which start to differ as losses in the receiver increase.

  2. Theoretical analysis, infrared and structural investigations of energy dissipation in metals under cyclic loading

    International Nuclear Information System (INIS)

    Plekhov, O.A.; Saintier, N.; Palin-Luc, T.; Uvarov, S.V.; Naimark, O.B.

    2007-01-01

    The infrared and structural investigations of energy dissipation processes in metals subjected to cyclic loading have given impetus to the development of a new thermodynamic model with the capability of describing the energy balance under plastic deformation. The model is based on the statistical description of the mesodefect ensemble evolution and its influence on the dissipation ability of the material. Constitutive equations have been formulated for plastic and structural strains, which allow us to describe the stored and dissipated parts of energy under plastic flow. Numerical results indicate that theoretical predictions are in good agreement with the experimentally observed temperature data

  3. Comparison of amount of physical load in the Czech and Austrian footballers at the same level of performance

    OpenAIRE

    Bujnovský, David

    2011-01-01

    Title: Comparison of the size of the motor load in the Czech and Austrian soccer players at the same performance level Objectives: The aim is to determine the size of the physical load of players during a football match. At the same time the next aim is to determinate the differences of physical load between Czech and Austrian soccer players at the same performance level. Methods: The indirect (mediated) observations was used in this bachelor thesis, because the data were recorded by computer...

  4. Modelling and analysis of a novel compressed air energy storage system for trigeneration based on electrical energy peak load shifting

    International Nuclear Information System (INIS)

    Lv, Song; He, Wei; Zhang, Aifeng; Li, Guiqiang; Luo, Bingqing; Liu, Xianghua

    2017-01-01

    Highlights: • A new CAES system for trigeneration based on electrical peak load shifting is proposed. • The theoretical models and the thermodynamics process are established and analyzed. • The relevant parameters influencing its performance have been discussed and optimized. • A novel energy and economic evaluation methods is proposed to evaluate the performance of the system. - Abstract: The compressed air energy storage (CAES) has made great contribution to both electricity and renewable energy. In the pursuit of reduced energy consumption and relieving power utility pressure effectively, a novel trigeneration system based on CAES for cooling, heating and electricity generation by electrical energy peak load shifting is proposed in this paper. The cooling power is generated by the direct expansion of compressed air, and the heating power is recovered in the process of compression and storage. Based on the working principle of the typical CAES, the theoretical analysis of the thermodynamic system models are established and the characteristics of the system are analyzed. A novel method used to evaluate energy and economic performance is proposed. A case study is conducted, and the economic-social and technical feasibility of the proposed system are discussed. The results show that the trigeneration system works efficiently at relatively low pressure, and the efficiency is expected to reach about 76.3% when air is compressed and released by 15 bar. The annual monetary cost saving annually is about 53.9%. Moreover, general considerations about the proposed system are also presented.

  5. Microcogeneration in buildings with low energy demand in load sharing application

    International Nuclear Information System (INIS)

    Angrisani, Giovanni; Canelli, Michele; Roselli, Carlo; Sasso, Maurizio

    2015-01-01

    Highlights: • The use of microcogenerator (MCHP) in buildings with low energy demand is evaluated. • The load sharing approach leads to suitable thermal and electric loads for MCHP. • Dynamic simulations are carried out considering two different climates. • A sensitivity analysis with respect to the self-consumed electricity is performed. • MCHPs with internal combustion engine perfectly match with well-insulated buildings. - Abstract: The paper investigates the introduction of a MCHP (Micro Combined Heat and Power) system in buildings with low energy demand with respect to the current building stock. A load sharing approach between a multifamily residential building and an office one is taken into account. Dynamic simulations are carried out in order to evaluate the thermo-economic performance of the analyzed system. Particular attention is given to the estimation of the electric load of the different users, as the economic profitability of a MCHP system is strongly influenced by the amount of self-consumed electricity. In order to analyze the influence of climatic conditions, two different geographical locations in Italy (Naples and Turin, having 1034 and 2617 heating degree days, respectively) are considered. The results of this study indicate that the installation of MCHP systems in buildings with low energy demand allows to increase the percentage of self-consumed electricity reducing the bidirectional electricity flow between the users and the external grid, as well as the impact on the grid itself due to the large diffusion of distributed generation systems. Moreover this study shows that the load sharing approach between users with different load profile leads to better energy, environmental and economic results with respect to a conventional system. The climatic conditions play an important role on the MCHP operational hours and hence on the thermo-economic performance of the system. The primary energy saving of the system located in Turin is

  6. Statistical interpretation of low energy nuclear level schemes

    Energy Technology Data Exchange (ETDEWEB)

    Egidy, T von; Schmidt, H H; Behkami, A N

    1988-01-01

    Nuclear level schemes and neutron resonance spacings yield information on level densities and level spacing distributions. A total of 75 nuclear level schemes with 1761 levels and known spins and parities was investigated. The A-dependence of level density parameters is discussed. The spacing distributions of levels near the groundstate indicate transitional character between regular and chaotic properties while chaos dominates near the neutron binding energy.

  7. Public policy analysis of energy efficiency and load management in changing electricity business

    Energy Technology Data Exchange (ETDEWEB)

    Vine, E. [Lawrence Berkeley National Laboratory, Berkeley, CA (United States). Energy Analysis Dept.; Hamrin, J. [Centre for Resource Solutions (United States); Eyre, N. [Energy Savings Trust (United Kingdom); Crossley, D.; Maloney, M.; Watt, G. [Energy Futures Australia Pty Ltd (Australia)

    2003-04-01

    The focus of this paper is (1) the potential effectiveness of the reform of the electricity industry on promoting energy efficiency and load management, and (2) the potential effectiveness of new mechanisms for promoting energy efficiency and load management. Many countries are initiating reforms of their power sectors to stimulate private investment, increase operation and management efficiencies, and lower the cost of power. These countries are unbundling vertically integrated utilities into distinct generation, transmission, distribution and retail supply companies; introducing commercial management principles to government-owned monopolies; and in many cases transferring operation or ownership to private companies. Electric industry restructuring may force regulators and policy makers to re-examine existing mechanisms for promoting load management and energy efficiency. In some cases, electric industry restructuring replaces the long-standing relationship between a single monopoly provider and protected customer franchise with a new set of relationships among retail electricity suppliers and customers who may now be free to choose suppliers. In these types of situations, markets, not government regulators and utility monopolies, are seen as determining future energy production and consumption decisions. However, it is uncertain whether this type of restructuring will overcome important market barriers to energy efficiency that limit markets for energy-efficient products and services from functioning effectively. As a result of these barriers, a large, untapped potential for cost-effective energy-efficiency investments exists. Supporters of public policies argue that energy-efficiency programs are an appropriate government strategy to capture economic efficiencies that the market cannot secure unassisted. (author)

  8. Public policy analysis of energy efficiency and load management in changing electricity businesses

    Energy Technology Data Exchange (ETDEWEB)

    Vine, Edward; Hamrin, Jan; Eyre, Nick; Crossley, David; Maloney, Michelle; Watt, Greg

    2003-04-01

    The focus of this paper is (1) the potential effectiveness of the reform of the electricity industry on promoting energy efficiency and load management, and (2) the potential effectiveness of new mechanisms for promoting energy efficiency and load management. Many countries are initiating reforms of their power sectors to stimulate private investment, increase operation and management efficiencies, and lower the cost of power. These countries are unbundling vertically integrated utilities into distinct generation, transmission, distribution and retail supply companies; introducing commercial management principles to government-owned monopolies; and in many cases transferring operation or ownership to private companies. Electric industry restructuring may force regulators and policy makers to re-examine existing mechanisms for promoting load management and energy efficiency. In some cases, electric industry restructuring replaces the long-standing relationship between a single monopoly provider and protected customer franchise with a new set of relationships among retail electricity suppliers and customers who may now be free to choose suppliers. In these types of situations, markets, not government regulators and utility monopolies, are seen as determining future energy production and consumption decisions. However, it is uncertain whether this type of restructuring will overcome important market barriers to energy efficiency that limit markets for energy-efficient products and services from functioning effectively. As a result of these barriers, a large, untapped potential for cost-effective energy-efficiency investments exists. Supporters of public policies argue that energy-efficiency programs are an appropriate government strategy to capture economic efficiencies that the market cannot secure unassisted.

  9. Public policy analysis of energy efficiency and load management in changing electricity businesses

    International Nuclear Information System (INIS)

    Vine, Edward; Hamrin, Jan; Eyre, Nick; Crossley, David; Maloney, Michelle; Watt, Greg

    2003-01-01

    The focus of this paper is (1) the potential effectiveness of the reform of the electricity industry on promoting energy efficiency and load management, and (2) the potential effectiveness of new mechanisms for promoting energy efficiency and load management. Many countries are initiating reforms of their power sectors to stimulate private investment, increase operation and management efficiencies, and lower the cost of power. These countries are unbundling vertically integrated utilities into distinct generation, transmission, distribution and retail supply companies; introducing commercial management principles to government-owned monopolies; and in many cases transferring operation or ownership to private companies. Electric industry restructuring may force regulators and policy makers to re-examine existing mechanisms for promoting load management and energy efficiency. In some cases, electric industry restructuring replaces the long-standing relationship between a single monopoly provider and protected customer franchise with a new set of relationships among retail electricity suppliers and customers who may now be free to choose suppliers. In these types of situations, markets, not government regulators and utility monopolies, are seen as determining future energy production and consumption decisions. However, it is uncertain whether this type of restructuring will overcome important market barriers to energy efficiency that limit markets for energy-efficient products and services from functioning effectively. As a result of these barriers, a large, untapped potential for cost-effective energy-efficiency investments exists. Supporters of public policies argue that energy-efficiency programs are an appropriate government strategy to capture economic efficiencies that the market cannot secure unassisted

  10. Energy Dependent Divisible Load Theory for Wireless Sensor Network Workload Allocation

    Directory of Open Access Journals (Sweden)

    Haiyan Shi

    2012-01-01

    Full Text Available The wireless sensor network (WSN, consisting of a large number of microsensors with wireless communication abilities, has become an indispensable tool for use in monitoring and surveillance applications. Despite its advantages in deployment flexibility and fault tolerance, the WSN is vulnerable to failures due to the depletion of limited onboard battery energy. A major portion of energy consumption is caused by the transmission of sensed results to the master processor. The amount of energy used, in fact, is related to both the duration of sensing and data transmission. Hence, in order to extend the operation lifespan of the WSN, a proper allocation of sensing workload among the sensors is necessary. An assignment scheme is here formulated on the basis of the divisible load theory, namely, the energy dependent divisible load theory (EDDLT for sensing workload allocations. In particular, the amount of residual energies onboard sensors are considered while deciding the workload assigned to each sensor. Sensors with smaller amount of residual energy are assigned lighter workloads, thus, allowing for a reduced energy consumption and the sensor lifespan is extended. Simulation studies are conducted and results have illustrated the effectiveness of the proposed workload allocation method.

  11. Energy conversion through mass loading of escaping ionospheric ions for different Kp values

    Science.gov (United States)

    Yamauchi, Masatoshi; Slapak, Rikard

    2018-01-01

    By conserving momentum during the mixing of fast solar wind flow and slow planetary ion flow in an inelastic way, mass loading converts kinetic energy to other forms - e.g. first to electrical energy through charge separation and then to thermal energy (randomness) through gyromotion of the newly born cold ions for the comet and Mars cases. Here, we consider the Earth's exterior cusp and plasma mantle, where the ionospheric origin escaping ions with finite temperatures are loaded into the decelerated solar wind flow. Due to direct connectivity to the ionosphere through the geomagnetic field, a large part of this electrical energy is consumed to maintain field-aligned currents (FACs) toward the ionosphere, in a similar manner as the solar wind-driven ionospheric convection in the open geomagnetic field region. We show that the energy extraction rate by the mass loading of escaping ions (ΔK) is sufficient to explain the cusp FACs, and that ΔK depends only on the solar wind velocity accessing the mass-loading region (usw) and the total mass flux of the escaping ions into this region (mloadFload), as ΔK ˜ -mloadFloadu2sw/4. The expected distribution of the separated charges by this process also predicts the observed flowing directions of the cusp FACs for different interplanetary magnetic field (IMF) orientations if we include the deflection of the solar wind flow directions in the exterior cusp. Using empirical relations of u0 ∝ Kp + 1.2 and Fload ∝ exp(0.45Kp) for Kp = 1-7, where u0 is the solar wind velocity upstream of the bow shock, ΔK becomes a simple function of Kp as log10(ΔK) = 0.2 ṡ Kp + 2 ṡ log10(Kp + 1.2) + constant. The major contribution of this nearly linear increase is the Fload term, i.e. positive feedback between the increase of ion escaping rate Fload through the increased energy consumption in the ionosphere for high Kp, and subsequent extraction of more kinetic energy ΔK from the solar wind to the current system by the increased

  12. Theory of energy level and its application in water-loop heat pump system

    International Nuclear Information System (INIS)

    Yu, Qi Dong

    2017-01-01

    Highlights: • Novel theory of saving energy and its application in water loop heat pump. • Reverse energy caused by units to water loop and its solution. • New method for determining the energy-saving range of water loop heat pump. • Capacity model of auxiliary heat source and its size for all building types. • Advice for reducing total energy consumption of water loop heat pump. - Abstract: It is a difficult problem to how to determine the reverse energy caused by units to water loop when a water-loop heat pump (WLHP) is in cooling and heating simultaneous mode, which not only has a great impact on energy-saving rate but also decides the use of auxiliary heat source in winter. This paper presents a theory of energy level to improve the research on WLHP system by using the relationship among building, circulating water and units. In this theory, the circulating water replaces building load as a new method to convert the reverse energy into energy change of circulating water and the equation of energy level also is built to determine the energy-saving range of WLHP system and report the capacity model of auxiliary heat source for all building types. An office building with different auxiliary powers is tested to analyze system operation characteristic and the effect of auxiliary heat source on unit and system and the results validate previous conclusions and suggest that an energy balance should be considered between units and auxiliary power to improve overall operation.

  13. EFFECT OF DIFFERENT LEVELS AGROECOLOGICAL LOADS ON BIOCHEMICAL CHARACTERISTICS OF SOIL

    Directory of Open Access Journals (Sweden)

    A. V. Shchur

    2016-01-01

    Full Text Available Aim. To study the effect of different levels of agri-environmental loads on the enzymatic activity of the soil.Methods. Isolation of soil fauna was conducted by thermogradient. Ecological characteristics of soil biota community was determined by ecological indices. The enzymatic activity of soil under different crops and at different levels of agri-environmental loads in our experiments was determined by methods proven in the laboratory soil enzymology Institute of Experimental Botany name V.F. Kuprevich and Belorussian Research Institute for Soil Science and Agricultural Chemistry.Results. Community soil biota is polydominant character, as evidenced by the values of environmental indices. It does not set a significant impact on the community agrotechnological loads of soil micro and mesofauna. Absolute figures soil phosphatase activity averaged over all embodiments without recourse formation were higher by 63% compared with plowing. Invertase and catalase activity was much higher in stubble on all variants of the experiment and selection of terms. The content of peroxidase lower under pure steam. The laws have taken place in respect of peroxidase activity, marked for polifenoloksidase activity.Main conclusion. There was no major change in the ecological characteristics of soil biota. In the enzymatic activity of soil influenced by sampling time, fertilizer system, soil tillage methods and cultivated crops.

  14. Comparing energy levels in isotropic and anisotropic potentials

    Energy Technology Data Exchange (ETDEWEB)

    Pikovski, Alexander, E-mail: alexander.pikovski@colorado.edu

    2015-11-06

    Qualitative information about the quantized energy levels of a system can be of great value. We study the relationship between the bound-state energies of an anisotropic potential and those of its spherical average. It is shown that the two ground-state energies satisfy an inequality, and there is a similar inequality for the first excited states. - Highlights: • Quantized energy levels in an arbitrary non-central potential are studied. • We derive inequalities between energies in a potential and its spherical average. • The results hold in three and two dimensions for any ground state and, with additional symmetry requirements for the first excited state.

  15. Comparing energy levels in isotropic and anisotropic potentials

    International Nuclear Information System (INIS)

    Pikovski, Alexander

    2015-01-01

    Qualitative information about the quantized energy levels of a system can be of great value. We study the relationship between the bound-state energies of an anisotropic potential and those of its spherical average. It is shown that the two ground-state energies satisfy an inequality, and there is a similar inequality for the first excited states. - Highlights: • Quantized energy levels in an arbitrary non-central potential are studied. • We derive inequalities between energies in a potential and its spherical average. • The results hold in three and two dimensions for any ground state and, with additional symmetry requirements for the first excited state.

  16. Wind Energy Management System Integration Project Incorporating Wind Generation and Load Forecast Uncertainties into Power Grid Operations

    Energy Technology Data Exchange (ETDEWEB)

    Makarov, Yuri V.; Huang, Zhenyu; Etingov, Pavel V.; Ma, Jian; Guttromson, Ross T.; Subbarao, Krishnappa; Chakrabarti, Bhujanga B.

    2010-09-01

    The power system balancing process, which includes the scheduling, real time dispatch (load following) and regulation processes, is traditionally based on deterministic models. Since the conventional generation needs time to be committed and dispatched to a desired megawatt level, the scheduling and load following processes use load and wind power production forecasts to achieve future balance between the conventional generation and energy storage on the one side, and system load, intermittent resources (such as wind and solar generation) and scheduled interchange on the other side. Although in real life the forecasting procedures imply some uncertainty around the load and wind forecasts (caused by forecast errors), only their mean values are actually used in the generation dispatch and commitment procedures. Since the actual load and intermittent generation can deviate from their forecasts, it becomes increasingly unclear (especially, with the increasing penetration of renewable resources) whether the system would be actually able to meet the conventional generation requirements within the look-ahead horizon, what the additional balancing efforts would be needed as we get closer to the real time, and what additional costs would be incurred by those needs. In order to improve the system control performance characteristics, maintain system reliability, and minimize expenses related to the system balancing functions, it becomes necessary to incorporate the predicted uncertainty ranges into the scheduling, load following, and, in some extent, into the regulation processes. It is also important to address the uncertainty problem comprehensively, by including all sources of uncertainty (load, intermittent generation, generators’ forced outages, etc.) into consideration. All aspects of uncertainty such as the imbalance size (which is the same as capacity needed to mitigate the imbalance) and generation ramping requirement must be taken into account. The latter unique

  17. Information Geometry, Inference Methods and Chaotic Energy Levels Statistics

    OpenAIRE

    Cafaro, Carlo

    2008-01-01

    In this Letter, we propose a novel information-geometric characterization of chaotic (integrable) energy level statistics of a quantum antiferromagnetic Ising spin chain in a tilted (transverse) external magnetic field. Finally, we conjecture our results might find some potential physical applications in quantum energy level statistics.

  18. Nonlinear modeling, strength-based design, and testing of flexible piezoelectric energy harvesters under large dynamic loads for rotorcraft applications

    Science.gov (United States)

    Leadenham, Stephen; Erturk, Alper

    2014-04-01

    There has been growing interest in enabling wireless health and usage monitoring for rotorcraft applications, such as helicopter rotor systems. Large dynamic loads and acceleration fluctuations available in these environments make the implementation of vibration-based piezoelectric energy harvesters a very promising choice. However, such extreme loads transmitted to the harvester can also be detrimental to piezoelectric laminates and overall system reliability. Particularly flexible resonant cantilever configurations tuned to match the dominant excitation frequency can be subject to very large deformations and failure of brittle piezoelectric laminates due to excessive bending stresses at the root of the harvester. Design of resonant piezoelectric energy harvesters for use in these environments require nonlinear electroelastic dynamic modeling and strength-based analysis to maximize the power output while ensuring that the harvester is still functional. This paper presents a mathematical framework to design and analyze the dynamics of nonlinear flexible piezoelectric energy harvesters under large base acceleration levels. A strength-based limit is imposed to design the piezoelectric energy harvester with a proof mass while accounting for material, geometric, and dissipative nonlinearities, with a focus on two demonstrative case studies having the same linear fundamental resonance frequency but different overhang length and proof mass values. Experiments are conducted at different excitation levels for validation of the nonlinear design approach proposed in this work. The case studies in this work reveal that harvesters exhibiting similar behavior and power generation performance at low excitation levels (e.g. less than 0.1g) can have totally different strength-imposed performance limitations under high excitations (e.g. above 1g). Nonlinear modeling and strength-based design is necessary for such excitation levels especially when using resonant cantilevers with no

  19. Utilizing an Energy Management System with Distributed Resources to Manage Critical Loads and Reduce Energy Costs

    Science.gov (United States)

    2014-09-01

    significant impact that energy usage has on their operations and their ability to conduct sustained expeditionary operations. In austere environments...efficiency and reduce environmental impact is to power the fuel cell using hydrogen obtained by electrolysis of water from a renewable energy source...look at other DR. Using microturbines and other natural gas cogeneration ( energy and heat) power generation systems is a more affordable way of

  20. Regulation of the energy infrastructure. Load management. Part 1. Fiscal aspects of energy networks

    International Nuclear Information System (INIS)

    Smits, L.

    2008-01-01

    The Dutch energy system depends on the presence of a good infrastructure. For many decades little attention was paid to infrastructure, but due to the liberalization infrastructure is receiving renewed attention. The grids are now considered the backbone of the energy system and essential for security of supply. Moreover, future electricity plants may have to adhere to the 'zero emission' demands in the future and (nearly) empty oil and gas fields will be used for underground storage of substances such as CO2. This new series addresses the existing and new regulation for the energy infrastructure. This edition addresses a number of fiscal aspects of the energy infrastructure. [mk] [nl

  1. Latching and Declutching Control of the Solo Duck Wave-Energy Converter with Different Load Types

    Directory of Open Access Journals (Sweden)

    Jinming Wu

    2017-12-01

    Full Text Available The solo duck wave-energy converter (WEC captures power in a point absorber manner, hence it exhibits high power-capture efficiency within only a narrow bandwidth. Passive control is characterized by a unidirectional power flow, and thus its engineering implementation can be simplified. In this paper, two typical passive control strategies, latching and declutching control, are applied to the solo duck WEC to improve its power-capture performance at wave periods larger and smaller than the natural period of the WEC, respectively. Special attention is paid to the peak value of instantaneous WEC performance parameters, including the peak motion excursion, the peak power take-off (PTO moment, and the peak-to-average power ratio, when the captured power is maximized. Performance differences between the linear and coulomb loads are also investigated. Results show that both latching and declutching control can effectively improve captured power, but also incidentally increase the peak motion excursion and peak-to-average power ratio. When under latching and declutching control, the coulomb load leads to the same maximum relative capture width and peak motion excursion as the linear load, but presents smaller peak PTO moment and peak-to-average power ratio than the linear load, hence making the coulomb load the better choice for the solo duck WEC.

  2. Estimation of metal pollutant loads from Nuclear and Energy Research Institute (Brazil)

    Energy Technology Data Exchange (ETDEWEB)

    Marques, Joyce R.; Monteiro, Lucilena R.; Soares, Sabrina M.V.; Stellato, Thamiris B.; Silva, Tatiane B.S.C.; Silva, Douglas B. da; Faustino, Mainara G.; Pires, Maria A.F.; Cotrim, Marycel E.B., E-mail: joyce.marques@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    According to National Environmental Council's (CONAMA) Resolution 357/05, pollutant load can be defined as the amount of a particular pollutant released in receiving water body; it is commonly expressed in a mass-time ratio. As specified in CONAMA's Resolution 430/11, the responsible for the pollutant source must present the Pollutant Load Declaration to environmental authorities. However, pollutant load knowledge is also important to the water quality maintenance and its environmental rating that must be kept to meet the requirements of the most restrictive use. In the control of metals releases is also important due public health matters, since they can cause harmful environmental contamination and major public health issues. Therefore this work aims to present the estimated metal pollutant load released by Nuclear and Energy Research Institute (IPEN/CNEN - Brazil), between 2013 and 2014. Results of cadmium, lead, copper, chromium, zinc, nickel, manganese, iron, barium, silver, boron and tin in composite samples (weekly) via Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES) and bromide (Br-) released as a tracer, to measure the wastewater flow were used to estimate IPEN's Metal Pollutant load. This study is part of the environmental assessment Program at IPEN, instituted since 2006 to the attendance of the current environmental legislation (CONAMA's Resolution 430/11, Article 19-A of State Decree 8.468/76 and State Decree 15.425/80). (author)

  3. Analysis of the Biceps Brachii Muscle by Varying the Arm Movement Level and Load Resistance Band

    Directory of Open Access Journals (Sweden)

    Nuradebah Burhan

    2017-01-01

    Full Text Available Biceps brachii muscle illness is one of the common physical disabilities that requires rehabilitation exercises in order to build up the strength of the muscle after surgery. It is also important to monitor the condition of the muscle during the rehabilitation exercise through electromyography (EMG signals. The purpose of this study was to analyse and investigate the selection of the best mother wavelet (MWT function and depth of the decomposition level in the wavelet denoising EMG signals through the discrete wavelet transform (DWT method at each decomposition level. In this experimental work, six healthy subjects comprised of males and females (26 ± 3.0 years and BMI of 22 ± 2.0 were selected as a reference for persons with the illness. The experiment was conducted for three sets of resistance band loads, namely, 5 kg, 9 kg, and 16 kg, as a force during the biceps brachii muscle contraction. Each subject was required to perform three levels of the arm angle positions (30°, 90°, and 150° for each set of resistance band load. The experimental results showed that the Daubechies5 (db5 was the most appropriate DWT method together with a 6-level decomposition with a soft heursure threshold for the biceps brachii EMG signal analysis.

  4. Analysis of the Biceps Brachii Muscle by Varying the Arm Movement Level and Load Resistance Band

    Science.gov (United States)

    Abdullah, Shahrum Shah; Jali, Mohd Hafiz

    2017-01-01

    Biceps brachii muscle illness is one of the common physical disabilities that requires rehabilitation exercises in order to build up the strength of the muscle after surgery. It is also important to monitor the condition of the muscle during the rehabilitation exercise through electromyography (EMG) signals. The purpose of this study was to analyse and investigate the selection of the best mother wavelet (MWT) function and depth of the decomposition level in the wavelet denoising EMG signals through the discrete wavelet transform (DWT) method at each decomposition level. In this experimental work, six healthy subjects comprised of males and females (26 ± 3.0 years and BMI of 22 ± 2.0) were selected as a reference for persons with the illness. The experiment was conducted for three sets of resistance band loads, namely, 5 kg, 9 kg, and 16 kg, as a force during the biceps brachii muscle contraction. Each subject was required to perform three levels of the arm angle positions (30°, 90°, and 150°) for each set of resistance band load. The experimental results showed that the Daubechies5 (db5) was the most appropriate DWT method together with a 6-level decomposition with a soft heursure threshold for the biceps brachii EMG signal analysis. PMID:29138687

  5. Cultural energy analyses of dairy cattle receiving different concentrate levels

    International Nuclear Information System (INIS)

    Koknaroglu, Hayati

    2010-01-01

    Purpose of this study was to conduct cultural energy analyses of dairy cows receiving different levels of concentrate. Data were acquired by conducting a survey on 132 dairy farms selected by the stratified random sampling method. Dairy cattle farms were divided into three groups according to concentrate level and were analyzed. Accordingly concentrate levels were assigned as low (LLC) ( 50%, 44 farms). Cultural energy used for feed for cows was calculated by multiplying each ingredient with corresponding values of ingredients from literature. Transportation energy was also included in the analysis. Total cultural energy expended was highest for LLC (P < 0.05). Cultural energy expended for feed constituted more than half of the total cultural energy and was highest for LLC (P < 0.05). Cultural energy expended per kg milk and per Mcal protein energy was higher for LLC (P < 0.05). Efficiency defined as Mcal input/Mcal output was better for ILC and was worse for LLC (P < 0.05) and HLC was intermediate thus not differing from other groups. Results show that cultural energy use efficiency does not linearly increases as concentrate level increases and increasing concentrate level does not necessarily mean better efficiency. Thus optimum concentrate level not interfering cows performance should be sought for sustainable dairy production.

  6. Direct Load Control (DLC) Considering Nodal Interrupted Energy Assessment Rate (NIEAR) in Restructured Power Systems

    DEFF Research Database (Denmark)

    Wu, Qiuwei; Wang, Peng; Goel, Lalit

    2010-01-01

    is used as the bids from the ACL customers, is utilized to determine the direct monetary compensation to the ACL customers. The proposed scheme was investigated for the PoolCo electricity market. The optimal DLC scheme is determined based on the minimum system operating cost which is comprised......A direct load control (DLC) scheme of air conditioning loads (ACL) considering direct monetary compensation to ACL customers for the service interruption caused by the DLC program is proposed in this paper for restructured power systems. The nodal interrupted energy assessment rate (NIEAR), which...... of the system energy cost, the system spinning reserve cost and the compensation cost to the ACL customers. Dynamic programming (DP) was used to obtain the optimal DLC scheme. The IEEE reliability test system (RTS) was studied to illustrate the proposed DLC scheme....

  7. Use of Three-Level Power Converters in Wind-Driven Permanent-Magnet Synchronous Generators with Unbalanced Loads

    Directory of Open Access Journals (Sweden)

    Ming-Hung Chen

    2015-06-01

    Full Text Available This paper describes the design and implementation of three-level power converters for wind-driven permanent-magnet synchronous generators with unbalanced loads. To increase voltage stress and reduce current harmonics in the electrical power generated by a wind generator, a three-phase, three-level rectifier is used. Because a synchronous rotating frame is used on the AC-input side, the use of a neutral-point-clamped controller is proposed to increase the power factor to unity and reduce current harmonics. Furthermore, a novel six-leg inverter is proposed for transferring energy from the DC voltage to a three-phase, four-wire AC source with a constant voltage and a constant frequency. The power converters also contain output transformers and filters for power buffering and filtering, respectively. All three output phase voltages are fed back to control the inverter output during load variations. A digital signal processor is used as the core control device for implementing a 1.5 kV, 75 kW drive system. Experimental data show that the power factor is successfully increased to unity and the total current harmonic distortion is 3.2% on the AC-input side. The entire system can attain an efficiency of 91%, and the voltage error between the upper and lower capacitors is approximately zero. Experimental results that confirm the high performance of the proposed system are presented.

  8. Quasi-static analysis of wave loadings on spine-based wave energy devices

    Energy Technology Data Exchange (ETDEWEB)

    Lockett, F.P.; Peatfield, A.M.; West, M.J.

    1980-02-01

    A report is given on the Wave Energy Research Programme at Lanchester Polytechnic. Results are presented for both theoretical and experimental scale models for wave loadings on circular and rectangular spines of various lengths. The results are in good agreement over the operational wave range for the 1/50 scale model and for the more limited data on the 1/10 scale model.

  9. An energy estimation framework for event-based methods in Non-Intrusive Load Monitoring

    International Nuclear Information System (INIS)

    Giri, Suman; Bergés, Mario

    2015-01-01

    Highlights: • Energy estimation is NILM has not yet accounted for complexity of appliance models. • We present a data-driven framework for appliance modeling in supervised NILM. • We test the framework on 3 houses and report average accuracies of 5.9–22.4%. • Appliance models facilitate the estimation of energy consumed by the appliance. - Abstract: Non-Intrusive Load Monitoring (NILM) is a set of techniques used to estimate the electricity consumed by individual appliances in a building from measurements of the total electrical consumption. Most commonly, NILM works by first attributing any significant change in the total power consumption (also known as an event) to a specific load and subsequently using these attributions (i.e. the labels for the events) to estimate energy for each load. For this last step, most published work in the field makes simplifying assumptions to make the problem more tractable. In this paper, we present a framework for creating appliance models based on classification labels and aggregate power measurements that can help to relax many of these assumptions. Our framework automatically builds models for appliances to perform energy estimation. The model relies on feature extraction, clustering via affinity propagation, perturbation of extracted states to ensure that they mimic appliance behavior, creation of finite state models, correction of any errors in classification that might violate the model, and estimation of energy based on corrected labels. We evaluate our framework on 3 houses from standard datasets in the field and show that the framework can learn data-driven models based on event labels and use that to estimate energy with lower error margins (e.g., 1.1–42.3%) than when using the heuristic models used by others

  10. Assessing the financial impacts of distributed energy on load serving entities

    International Nuclear Information System (INIS)

    Wang, Zeyu; Negash, Ahlmahz; Kirschen, Daniel

    2015-01-01

    This article analyzes the financial impact of distributed energy resources (DERs) owned and operated by commercial customers on the load serving entities (LSEs). DERs reduce the customers' electricity bills and hence the revenues collected by their LSE. However, changes in customer demand profiles can potentially reduce the aggregated system demand profile, and therefore, reduce the LSE's costs in wholesale markets. Analysis of these financial impacts indicates that the LSE's lost revenue ultimately outweighs its reduced expenses. This is largely due to a significant reduction in revenue from demand charges. Dispatchable DERs, including energy storages and demand response, result in more financial losses for LSEs than photovoltaics. The financial losses LSEs face indicate that redesigning commercial customer tariffs is necessary in order for LSEs to accommodate customer owned DERs properly. Several suggestions on modifying commercial tariffs are presented. - Highlights: • We analyze the financial impacts on load serving entities of DERs owned by commercial customers. • Under the selected commercial tariff, load serving entities suffer economic losses. • Energy storages and demand response results in more financial losses for LSE than photovoltaics. • We provide some suggestions for tariff modifications.

  11. Economic assessment of energy storage for load shifting in Positive Energy Building

    DEFF Research Database (Denmark)

    Dumont, Olivier; Carmo, Carolina; Georges, Emeline

    2016-01-01

    Net Zero Energy Buildings (NZEB) and Positive Energy Buildings (PEB) are gaining more and more interest. In this paper, the impact of the integration of a battery in a positive energy building is assessed in order to increase its self-consumption of electricity. Parametric studies are carried out......-in tariff and a 5 kWh battery. Finally, simple correlations (based on the feed-in tariff, the annual electrical consumption and production) to predict the optimal size of battery and the lowest payback period are proposed.......Net Zero Energy Buildings (NZEB) and Positive Energy Buildings (PEB) are gaining more and more interest. In this paper, the impact of the integration of a battery in a positive energy building is assessed in order to increase its self-consumption of electricity. Parametric studies are carried out...... by varying the building envelope characteristics, the power supply system, the climate, the lightning and appliances profiles, the roof tilt, the battery size and the electricity tariffs, leading to 3200 cases. The analysis is performed on an annual basis in terms of self-consumption rate, shifted energy...

  12. ANALYSIS OF ENERGY EFFICIENCY OF OPERATING MODES OF ELECTRICAL SYSTEMS WITH THE TRACTION LOADS

    Directory of Open Access Journals (Sweden)

    V. E. Bondarenko

    2017-03-01

    Full Text Available Innovative scenarios of reliable energy supply of transportation process aimed at reducing the specific energy consumption and increase energy efficiency of the systems of electric traction. The paper suggests innovative energy saving directions in traction networks of railways and new circuit solutions accessing traction substations in energy systems networks, ensure energy security of the transportation process. To ensure the energy security of rail transport special schemes were developed to propose the concept of external power traction substations, which would increase the number of connections to the networks of 220 – 330 kV, as well as the creation of transport and energy corridors, development of its own supply of electric networks of 110 kV substations and mobile RP-110 kV of next generation. Therefore, the investment program of the structures owned by the Ukrainian Railways (Ukrzaliznytsia need to be synchronized in their technological characteristics, as well as the criteria of reliability and quality of power supply with the same external energy investment programs. It is found that without any load on left or right supplying arm one of two less loaded phases of traction transformer begins generating specific modes in the supplying three-phase line. Thus, modes of mobile substation cause leakage in one of the phases of the supply line of traction transformers of active-capacitive current, and as a result generating energy in the main power line of 154 kV, which is fixed and calculated by electricity meters. For these three phase mode supply network is necessary to use 1st algorithm, i.e. taking into account the amount of electricity as the energy in all phases. For effective application of reactive power compensation devices in the AC traction power supply systems it is proposed to develop regulatory documentation on necessity of application and the order of choice of parameters and placement of compensation systems taking into

  13. Meso-level analysis, the missing link in energy strategies

    International Nuclear Information System (INIS)

    Schenk, Niels J.; Moll, Henri C.; Schoot Uiterkamp, Anton J.M.

    2007-01-01

    Energy is essential for human societies. Energy systems, though, are also associated with several adverse environmental effects. So far societies have been unable to successfully change their energy systems in a way that addresses environmental and health concerns. Lack of policy consensus often resulted in so-called 'stop-go' policies, which were identified as some of the most important barriers regarding successful energy transitions. The lack of policy consensus and coherent long-term strategies may result from a lack of knowledge of energy systems' meso-level dynamics. The meso-level involves the dynamic behaviour of the individual system elements and the coupling of individual technologies, resulting in interdependencies and regimes. Energy systems are at the meso-level characterised by two typical aspects, i.e. dynamics driven by interactions between actors, and heterogeneous characteristics of actors. These aspects give rise to the ineffectiveness of traditional energy policies, which is illustrated with examples from the transport sector and household electricity consumption. We found that analysis of energy systems at the meso-level helps to better understand energy systems. To resolve persistent policy issues, the traditional 'one size fits all' energy policies are not sufficient. In order to tackle the difficult issues, 'redesign of system organisation', 'target group approach', or 'target group induced system re-orientation' are needed

  14. Investigating Theoretical PV Energy Generation Patterns with Their Relation to the Power Load Curve in Poland

    Directory of Open Access Journals (Sweden)

    Jakub Jurasz

    2016-01-01

    Full Text Available Polish energy sector is (almost from its origin dominated by fossil fuel feed power. This situation results from an abundance of relatively cheap coal (hard and lignite. Brown coal due to its nature is the cheapest energy source in Poland. However, hard coal which fuels 60% of polish power plants is picking up on prices and is susceptible to the coal imported from neighboring countries. Forced by the European Union (EU regulations, Poland is struggling at achieving its goal of reaching 15% of energy consumption from renewable energy sources (RES by 2020. Over the year 2015, RES covered 11.3% of gross energy consumption but this generation was dominated by solid biomass (over 80%. The aim of this paper was to answer the following research questions: What is the relation of irradiation values to the power load on a yearly and daily basis? and how should photovoltaics (PV be integrated in the polish power system? Conducted analysis allowed us to state that there exists a negative correlation between power demand and irradiation values on a yearly basis, but this is likely to change in the future. Secondly, on average, daily values of irradiation tend to follow power load curve over the first hours of the day.

  15. Large Hybrid Energy Systems for Making Low CO2 Load-Following Power and Synthetic Fuel

    International Nuclear Information System (INIS)

    Cherry, Robert S.; Boardman, Richard D.; Aumeier, Steven

    2012-01-01

    Hybrid energy systems using nuclear heat sources can economically produce load-following electrical power by exploiting the surplus generation capacity available at night or seasonally to make synthetic fuel. Vehicle fuel is the only current energy use large enough to absorb all the energy capacity that might be diverted from the power industry, and its ease of storage obviates problems with discontinuous synfuel production. The potential benefits and challenges of synfuels integration are illustrated by the production of methanol from natural gas (as a source of carbon) using steam from a light water nuclear power reactor which is assumed to be available in accord with a year's worth of power demand data. Methanol's synthesis process is easily adapted to using 300 C heat from a light water reactor and this simple compound can be further processed into gasoline, biodiesel, or dimethyl ether, fuels which can be used with the current vehicle fleet. A supplemental feed to the methanol process of natural gas (for energy) allows operation at constant full rate when the nuclear heat is being used to produce electrical power. The higher capital costs of such a system are offset by a lower cost of heat and power production from a large base load type of plant and by reduced costs associated with much lower CO2 emissions. Other less tangible economic benefits of this and similar hybrid systems include better use of natural resource for fuels and greater energy services security from the domestic production of vehicle fuel.

  16. Herpesviruses viral loads and levels of proinflammatory cytokines in apical periodontitis.

    Science.gov (United States)

    Jakovljevic, A; Knezevic, A; Nikolic, N; Soldatovic, I; Jovanovic, T; Milasin, J; Andric, M

    2018-07-01

    This study aimed to analyse Epstein-Barr virus (EBV) and human cytomegalovirus (HCMV) viral loads in symptomatic and asymptomatic apical periodontitis lesions, to determine levels of TNF-α, IL-1β and IL-6 in these lesions and to investigate a possible correlation between herpesviral copy numbers and levels of proinflammatory cytokines. A total of 100 samples of apical periodontitis were subjected to HCMV and EBV copy numbers analysis by nested polymerase chain reaction (PCR) and TaqMan real-time PCR. The concentrations of TNF-α, IL-1β and IL-6 were determined by ELISA method. SPSS software was used for statistical analysis. There were no significant differences in the occurrence of EBV and HCMV between symptomatic and asymptomatic periapical lesions (p = .686, p = .879, respectively). Only 12 of 74 EBV (16.2%) and four of 54 HCMV (13.5%) nested PCR-positive samples showed increased viral copy numbers above the limit of 125 copies/ml. There was no significant correlation between the levels of analysed proinflammatory cytokines and herpesviral copy numbers in our sample. The observed low viral loads point to a relatively rare occurrence of active EBV and HCMV infection in our sample. Latent herpesviral infection does not enhance the production of investigated proinflammatory cytokines. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd. All rights reserved.

  17. Inferring Parametric Energy Consumption Functions at Different Software Levels

    DEFF Research Database (Denmark)

    Liqat, Umer; Georgiou, Kyriakos; Kerrison, Steve

    2016-01-01

    The static estimation of the energy consumed by program executions is an important challenge, which has applications in program optimization and verification, and is instrumental in energy-aware software development. Our objective is to estimate such energy consumption in the form of functions...... on the input data sizes of programs. We have developed a tool for experimentation with static analysis which infers such energy functions at two levels, the instruction set architecture (ISA) and the intermediate code (LLVM IR) levels, and reflects it upwards to the higher source code level. This required...... the development of a translation from LLVM IR to an intermediate representation and its integration with existing components, a translation from ISA to the same representation, a resource analyzer, an ISA-level energy model, and a mapping from this model to LLVM IR. The approach has been applied to programs...

  18. How to Draw Energy Level Diagrams in Excitonic Solar Cells.

    Science.gov (United States)

    Zhu, X-Y

    2014-07-03

    Emerging photovoltaic devices based on molecular and nanomaterials are mostly excitonic in nature. The initial absorption of a photon in these materials creates an exciton that can subsequently dissociate in each material or at their interfaces to give charge carriers. Any attempt at mechanistic understanding of excitonic solar cells must start with drawing energy level diagrams. This seemingly elementary exercise, which is described in textbooks for inorganic solar cells, has turned out to be a difficult subject in the literature. The problem stems from conceptual confusion of single-particle energy with quasi-particle energy and the misleading practice of mixing the two on the same energy level diagram. Here, I discuss how to draw physically accurate energy diagrams in excitonic solar cells using only single-particle energies (ionization potentials and electron affinities) of both ground and optically excited states. I will briefly discuss current understanding on the electronic energy landscape responsible for efficient charge separation in excitonic solar cells.

  19. Passive Method to Reduce Solar Energy Effect on the Cooling Load in Buildings

    Directory of Open Access Journals (Sweden)

    Orfi J.

    2012-10-01

    Full Text Available Energy needed for cooling residential and industrial buildings in hot weather countries is the major issue. The period needed for cooling or comfort conditions in those countries exceeds five months and outdoor temperature reaches more than 40 °C. Also, the solar intensity usually high and can reach about one kW per m2. Hence, any attempt to reduce the effect of solar energy on the cooling load is worthy to investigate. The present work analyzes using artificial, naturally ventilated, shading covers to reduce the effect of solar energy. Analytical and numerical analyzes were performed on the effect of adding a ventilated cover to walls and roof exposed to the solar energy.

  20. Matching of renewable source of energy generation graphs and electrical load in local energy system

    Science.gov (United States)

    Lezhniuk, Petro; Komar, Vyacheslav; Sobchuk, Dmytro; Kravchuk, Sergiy; Kacejko, Piotr; Zavidsky, Vladislav

    2017-08-01

    The paper contains the method of matching generation graph of photovoltaic electric stations and consumers. Characteristic feature of this method is the application of morphometric analysis for assessment of non-uniformity of the integrated graph of energy supply, optimal coefficients of current distribution, that enables by mean of refining the powers, transferring in accordance with the graph , to provide the decrease of electric energy losses in the grid and transport task, as the optimization tool.

  1. Economic assessment of electric energy storage for load shifting in positive energy building

    DEFF Research Database (Denmark)

    Dumont, Olivier; Do Carmo, Carolina Madeira Ramos; Georges, Emeline

    2017-01-01

    Net zero energy buildings and positive energy buildings are gaining more and more interest. This paper evaluates the impact of the integration of a battery in a positive energy building used to increase its self-consumption of electricity. Parametric studies are carried out by varying the buildin...... and a 3.7 kWh battery. Finally, simple correlations (based on the feed-in tariff, the annual electrical consumption and production) to predict the optimal size of battery and the lowest payback period are proposed.......Net zero energy buildings and positive energy buildings are gaining more and more interest. This paper evaluates the impact of the integration of a battery in a positive energy building used to increase its self-consumption of electricity. Parametric studies are carried out by varying the building...... envelope characteristics, the power supply system, the climate, the lighting and appliances profiles, the roof tilt angle, the battery size and the electricity tariffs, leading to 3200 cases. The analysis is performed on an annual basis in terms of self-consumption and self-production rate and payback...

  2. Pre-slaughter sound levels and pre-slaughter handling from loading at the farm till slaughter influence pork quality.

    Science.gov (United States)

    Vermeulen, L; Van de Perre, V; Permentier, L; De Bie, S; Verbeke, G; Geers, R

    2016-06-01

    This study investigates the relationship between sound levels, pre-slaughter handling during loading and pork quality. Pre-slaughter variables were investigated from loading till slaughter. A total of 3213 pigs were measured 30 min post-mortem for pH(30LT) (M. Longissimus thoracis). First, a sound level model for the risk to develop PSE meat was established. The difference in maximum and mean sound level during loading, mean sound level during lairage and mean sound level prior to stunning remained significant within the model. This indicated that sound levels during loading had a significant added value to former sound models. Moreover, this study completed the global classification checklist (Vermeulen et al., 2015a) by developing a linear mixed model for pH(30LT) and PSE prevalence, with the difference in maximum and mean sound level measured during loading, the feed withdrawal period and the difference in temperature during loading and lairage. Hence, this study provided new insights over previous research where loading procedures were not included. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. An adaptive clustering approach to dynamic load balancing and energy efficiency in wireless sensor networks

    International Nuclear Information System (INIS)

    Gherbi, Chirihane; Aliouat, Zibouda; Benmohammed, Mohamed

    2016-01-01

    Clustering is a well known approach to cope with large nodes density and efficiently conserving energy in Wireless Sensor Networks (WSN). Load balancing is an effective approach for optimizing resources like channel bandwidth, the main objective of this paper is to combine these two valuable approaches in order to significantly improve the main WSN service such as information routing. So, our proposal is a routing protocol in which load traffic is shared among cluster members in order to reduce the dropping probability due to queue overflow at some nodes. To this end, a novel hierarchical approach, called Hierarchical Energy-Balancing Multipath routing protocol for Wireless Sensor Networks (HEBM) is proposed. The HEBM approach aims to fulfill the following purposes: decreasing the overall network energy consumption, balancing the energy dissipation among the sensor nodes and as direct consequence: extending the lifetime of the network. In fact, the cluster-heads are optimally determined and suitably distributed over the area of interest allowing the member nodes reaching them with adequate energy dissipation and appropriate load balancing utilization. In addition, nodes radio are turned off for fixed time duration according to sleeping control rules optimizing so their energy consumption. The performance evaluation of the proposed protocol is carried out through the well-known NS2 simulator and the exhibited results are convincing. Like this, the residual energy of sensor nodes was measured every 20 s throughout the duration of simulation, in order to calculate the total number of alive nodes. Based on the simulation results, we concluded that our proposed HEBM protocol increases the profit of energy, and prolongs the network lifetime duration from 32% to 40% compared to DEEAC reference protocol and from 25% to 28% compared to FEMCHRP protocol. The authors also note that the proposed protocol is 41.7% better than DEEAC with respect to FND (Fist node die), and 25

  4. Energy cost and mechanical work of walking during load carriage in soldiers.

    Science.gov (United States)

    Grenier, Jordane G; Peyrot, Nicolas; Castells, Josiane; Oullion, Roger; Messonnier, Laurent; Morin, Jean-Benoit

    2012-06-01

    In the military context, soldiers carry equipments of total mass often exceeding 30%-40% of their body mass (BM) and complexly distributed around their body (backpack, weapons, electronics, protections, etc.), which represents severe load carrying conditions. This study aimed to better understand the effects of load carriage on walking energetics and mechanics during military-type walking. Ten male infantrymen recently retired from the French Foreign Legion performed 3-min walking trials at a constant speed of 4 km·h(-1) on an instrumented treadmill, during which walking pattern spatiotemporal parameters, energy cost (C(W)), external mechanical work (W(ext)), and the work done by one leg against the other during the double-contact period (W(int,dc)) were specifically assessed. Three conditions were tested: (i) light sportswear (SP, reference condition considered as unloaded), (ii) battle equipment (BT, ∼22 kg, ∼27% of subjects' BM, corresponding to a military intermediate load), and (iii) road march equipment (RM, ∼38 kg, ∼46% of subjects' BM, corresponding to a military high load). Repeated-measures ANOVA showed that military equipment carriage significantly (i) altered the spatiotemporal pattern of walking (all P < 0.01), (ii) increased absolute gross and net CW (P < 0.0001), and (iii) increased both absolute and mass-relative W(ext) (P < 0.01) and W(int,dc) (P < 0.0001) but did not alter the inverted pendulum recovery or locomotor efficiency. Military equipments carriage induced significant changes in walking mechanics and energetics, but these effects appeared not greater than those reported with loads carried around the waist and close to the center of mass. This result was not expected because the latter has been hypothesized to be the optimal method of load carriage from a metabolic standpoint.

  5. Histogram plots and cutoff energies for nuclear discrete levels

    International Nuclear Information System (INIS)

    Belgya, T.; Molnar, G.; Fazekas, B.; Oestoer, J.

    1997-05-01

    Discrete level schemes for 1277 nuclei, from 6 Li through 251 Es, extracted from the Evaluated Nuclear Structure Data File were analyzed. Cutoff energies (U max ), indicating the upper limit of level scheme completeness, were deduced from the inspection of histograms of the cumulative number of levels. Parameters of the constant-temperature level density formula (nuclear temperature T and energy shift U 0 ) were obtained by means of the least square fit of the formula to the known levels below cutoff energy. The results are tabulated for all 1277 nuclei allowing for an easy and reliable application of the constant-temperature level density approach. A complete set of cumulative plots of discrete levels is also provided. (author). 5 figs, 2 tabs

  6. Realistic level densities in fragment emission at high excitation energies

    International Nuclear Information System (INIS)

    Mustafa, M.G.; Blann, M.; Ignatyuk, A.V.

    1993-01-01

    Heavy fragment emission from a 44 100 Ru compound nucleus at 400 and 800 MeV of excitation is analyzed to study the influence of level density models on final yields. An approach is used in which only quasibound shell-model levels are included in calculating level densities. We also test the traditional Fermi gas model for which there is no upper energy limit to the single particle levels. We compare the influence of these two level density models in evaporation calculations of primary fragment excitations, kinetic energies and yields, and on final product yields

  7. Robust Building Energy Load Forecasting Using Physically-Based Kernel Models

    Directory of Open Access Journals (Sweden)

    Anand Krishnan Prakash

    2018-04-01

    Full Text Available Robust and accurate building energy load forecasting is important for helping building managers and utilities to plan, budget, and strategize energy resources in advance. With recent prevalent adoption of smart-meters in buildings, a significant amount of building energy consumption data became available. Many studies have developed physics-based white box models and data-driven black box models to predict building energy consumption; however, they require extensive prior knowledge about building system, need a large set of training data, or lack robustness to different forecasting scenarios. In this paper, we introduce a new building energy forecasting method based on Gaussian Process Regression (GPR that incorporates physical insights about load data characteristics to improve accuracy while reducing training requirements. The GPR is a non-parametric regression method that models the data as a joint Gaussian distribution with mean and covariance functions and forecast using the Bayesian updating. We model the covariance function of the GPR to reflect the data patterns in different forecasting horizon scenarios, as prior knowledge. Our method takes advantage of the modeling flexibility and computational efficiency of the GPR while benefiting from the physical insights to further improve the training efficiency and accuracy. We evaluate our method with three field datasets from two university campuses (Carnegie Mellon University and Stanford University for both short- and long-term load forecasting. The results show that our method performs more accurately, especially when the training dataset is small, compared to other state-of-the-art forecasting models (up to 2.95 times smaller prediction error.

  8. ARRA-Multi-Level Energy Storage and Controls for Large-Scale Wind Energy Integration

    Energy Technology Data Exchange (ETDEWEB)

    David Wenzhong Gao

    2012-09-30

    The Project Objective is to design innovative energy storage architecture and associated controls for high wind penetration to increase reliability and market acceptance of wind power. The project goals are to facilitate wind energy integration at different levels by design and control of suitable energy storage systems. The three levels of wind power system are: Balancing Control Center level, Wind Power Plant level, and Wind Power Generator level. Our scopes are to smooth the wind power fluctuation and also ensure adequate battery life. In the new hybrid energy storage system (HESS) design for wind power generation application, the boundary levels of the state of charge of the battery and that of the supercapacitor are used in the control strategy. In the controller, some logic gates are also used to control the operating time durations of the battery. The sizing method is based on the average fluctuation of wind profiles of a specific wind station. The calculated battery size is dependent on the size of the supercapacitor, state of charge of the supercapacitor and battery wear. To accommodate the wind power fluctuation, a hybrid energy storage system (HESS) consisting of battery energy system (BESS) and super-capacitor is adopted in this project. A probability-based power capacity specification approach for the BESS and super-capacitors is proposed. Through this method the capacities of BESS and super-capacitor are properly designed to combine the characteristics of high energy density of BESS and the characteristics of high power density of super-capacitor. It turns out that the super-capacitor within HESS deals with the high power fluctuations, which contributes to the extension of BESS lifetime, and the super-capacitor can handle the peaks in wind power fluctuations without the severe penalty of round trip losses associated with a BESS. The proposed approach has been verified based on the real wind data from an existing wind power plant in Iowa. An

  9. Peak Load Regulation and Cost Optimization for Microgrids by Installing a Heat Storage Tank and a Portable Energy System

    Directory of Open Access Journals (Sweden)

    Hong Zhang

    2018-04-01

    Full Text Available With the rapid growth of electricity demands, many traditional distributed networks cannot cover their peak demands, especially in the evening. Additionally, with the interconnection of distributed electrical and thermal grids, system operational flexibility and energy efficiency can be affected as well. Therefore, by adding a portable energy system and a heat storage tank to the traditional distributed system, this paper proposes a newly defined distributed network to deal with the aforementioned problems. Simulation results show that by adding a portable energy system, fossil fuel energy consumption and daily operation cost can be reduced by 8% and 28.29%, respectively. Moreover, system peak load regulating capacity can be significantly improved. However, by introducing the portable energy system to the grid, system uncertainty can be increased to some extent. Therefore, chance constrained programming is proposed to control the system while considering system uncertainty. By applying Particle Swarm Optimization—Monte Carlo to solve the chance constrained programming, results show that power system economy and uncertainty can be compromised by selecting appropriate confidence levels α and β. It is also reported that by installing an extra heat storage tank, combined heat and power energy efficiency can be significantly improved and the installation capacity of the battery can be reduced.

  10. Parametric Statistics of Individual Energy Levels in Random Hamiltonians

    OpenAIRE

    Smolyarenko, I. E.; Simons, B. D.

    2002-01-01

    We establish a general framework to explore parametric statistics of individual energy levels in disordered and chaotic quantum systems of unitary symmetry. The method is applied to the calculation of the universal intra-level parametric velocity correlation function and the distribution of level shifts under the influence of an arbitrary external perturbation.

  11. The impact of hybrid energy storage on power quality, when high power pulsed DC loads are operated on a microgrid testbed

    Science.gov (United States)

    Kelley, Jay Paul

    . This enables the generator to maintain its operation at levels of high efficiency thereby increasing the power quality of the AC bus. The work discussed here is aimed at evaluating how the use of energy storage impacts the power quality on MicroGrid's AC bus when high rate DC and AC loads are sourced simultaneously. Also HESM has been developed and evaluated as a mean to optimizing both the power and energy density of the energy storage installed.

  12. The effects of combining dynamic pricing, AC load control, and real-time energy feedback. SMUD'S 2011 Residential Summer Solutions Study

    Energy Technology Data Exchange (ETDEWEB)

    Herter, K. [Herter Energy Research Solutions, El Dorado Hills, CA (United States); Wood, V. [Sacramento Municipal Utility District, Sacramento, CA (United States); Blozis, S. [University of California, Davis, CA (United States)

    2013-11-15

    The 2011 Residential Summer Solutions Study compared the hourly load effects of three different real-time information treatments and two program options. The information treatments included: Baseline information (no real-time data), real-time Home information (whole-house data), and real-time Appliance information (data for the whole house plus three individual appliances). Compared to the Baseline group, real-time Home information lowered overall energy use by about 4 %. Real-time information at both the Home and Appliance levels had a significant effect on non-event peak loads: compared to the Baseline group, real-time Home data lowered peak load by 5 %, while Appliance data lowered peak load by 7 %. All three information treatments averaged a 1-kW (40 %) load shed during events. The customer-chosen program options included a dynamic time-of-use rate and a load control incentive program. Customers were more likely to sign up for the dynamic rate, and those who did saved significantly more peak load on both event days (>50 % savings) and non-event days (>20 % savings) than did those on the load control program alone. In addition, those on the dynamic rate saved twice as much on their summer bills as did those who chose to remain on the standard tiered rate. At the end of the summer, more than 90 % of participants signed up to participate again the following year.

  13. Frictional systems under periodic loads — History-dependence, non-uniqueness and energy dissipation

    International Nuclear Information System (INIS)

    Barber, J R

    2012-01-01

    Nominally static contacts such as bolted or shrink-fit joints typically experience regions of microslip when subjected to oscillatory loading. This results in energy dissipation, reflected as apparent hysteretic damping of the system, and also may cause the initiation of fretting fatigue cracks. Early theoretical studies of the Hertzian contact problem by Cattaneo and Mindlin were confirmed experimentally by Johnson, who identified signs of fretting damage in the slip annulus predicted by the theory. For many years, tribologists assumed that Melan's theorem in plasticity could be extended to frictional systems — i.e. that if there exists a state of residual stress associated with frictional slip that is sufficient to prevent periodic slip in the steady state, then the system will shake down, regardless of the initial condition. However, we now know that this is true only if there is no coupling between the normal and tangential loading problems, as will be the case notably when contact occurs on a symmetry plane. For all other cases, periodic loading scenarios can be devised such that shakedown occurs for some initial conditions and not for others. The initial condition here might be determined by the assembly protocol — e.g. the order in which a set of bolts is tightened — or by the exact loading path before the steady cycle is attained. This non-uniqueness of the steady state persists at load amplitudes above the shakedown limit, in which case there is always some dissipation, but the dissipation per cycle (and hence both the effective damping and the susceptibility to fretting damage) depends on the initial conditions. This implies that fretting fatigue experiments need to follow a well-defined assembly protocol if reproducible results are to be obtained. We shall also present results showing that when both normal and tangential forces vary in time, the energy dissipation is very sensitive to the relative phase of the oscillatory components, being greatest

  14. Analyzing the Energy Performance, Wind Loading, and Costs of Photovoltaic Slat Modules on Commercial Rooftops

    Energy Technology Data Exchange (ETDEWEB)

    Van Geet, Otto D. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Fu, Ran [National Renewable Energy Lab. (NREL), Golden, CO (United States); Horowitz, Kelsey A. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Kurup, Parthiv [National Renewable Energy Lab. (NREL), Golden, CO (United States); MacAlpine, Sara M. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Silverman, Timothy J. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2018-02-13

    NREL studied a new type of photovoltaic (PV) module configuration wherein multiple narrow, tilted slats are mounted in a single frame. Each slat of the PV slat module contains a single row of cells and is made using ordinary crystalline silicon PV module materials and processes, including a glass front sheet and weatherproof polymer encapsulation. Compared to a conventional ballasted system, a system using slat modules offer higher energy production and lower weight at lower LCOE. The key benefits of slat modules are reduced wind loading, improved capacity factor and reduced installation cost. First, the individual slats allow air to flow through, which reduce wind loading. Using PV performance modeling software, we compared the performance of an optimized installation of slats modules to a typical installation of conventional modules in a ballasted rack mounting system. Based on the results of the performance modeling two different row tilt and spacing were tested in a wind tunnel. Scaled models of the PV Slat modules were wind tunnel tested to quantify the wind loading of a slat module system on a commercial rooftop, comparing the results to conventional ballasted rack mounted PV modules. Some commercial roofs do not have sufficient reserve dead load capacity to accommodate a ballasted system. A reduced ballast system design could make PV system installation on these roofs feasible for the first time without accepting the disadvantages of penetrating mounts. Finally, technoeconomic analysis was conducted to enable an economic comparison between a conventional commercial rooftop system and a reduced-ballast slat module installation.

  15. Loaded and unloaded jump performance of top-level volleyball players from different age categories.

    Science.gov (United States)

    Kitamura, Katia; Pereira, Lucas Adriano; Kobal, Ronaldo; Cal Abad, Cesar Cavinato; Finotti, Ronaldo; Nakamura, Fábio Yuzo; Loturco, Irineu

    2017-09-01

    The aim of this study was to investigate the differences in loaded and unloaded jump performances between different age categories of top-level volleyball players from the same club. Forty-three volleyball players were divided into four age groups: under-17, under-19, under-21 and professional. Vertical jumping height for squat jump (SJ), countermovement jump (CMJ) and CMJ with arm swing (CMJa) and mean propulsive velocity (MPV) in the loaded jump squat exercise with 40% of the athlete's body mass were compared among the different age categories, considering body mass as a covariate. SJ and CMJ jump height values were higher for professional and under-21 players than under-17 players (pjump squat was higher for under-21 players than under-17 players (pjump performances across different age categories of top-level volleyball players. Therefore, to increase the vertical jumping ability of these team sport athletes throughout their long-term development, coaches and strength and conditioning professionals are encouraged to implement consistent neuromuscular training strategies, in accordance with the specific needs and physiological characteristics of each age group.

  16. THE INFLUENCE OF SWIMMING IN DIFFERENT LOAD REGIMES ON THE LEVEL OF ANXIOUSNESS

    Directory of Open Access Journals (Sweden)

    Dragan Krivokapić

    2008-08-01

    Full Text Available On the sample of 32 males aged between 18 and 19 characterized asambicious amateur athletes and good swimmers, an experiment was carried out with parallel groups with a view to evaluating the effects of two different programmes of swimming training. The specimen was divided into two homogenous subspecimens of 15 and 17 examinees.The groups were evened out according to the level of specific anxiousnes.The initial and the final approximation was carried out according to two equivalent tests (Martens- SCAT and Martens CSI-2 already standardized in the previous researches. The experiment lasted eight weeks with three training sessions per week. Sessions were different depending on the specific group i.e. program .The first group of examinees always swam in the regime of aerobic load while the other was occasionally exposed to anaerobic load. In ten sity of swimming was based on the criterion of anaerobic threshold. The results of the discriminatory statistics showed the absence of significant changes in both experimental groups which remained quite levelled after the final test.

  17. 27-Level DC–AC inverter with single energy source

    International Nuclear Information System (INIS)

    Tsang, K.M.; Chan, W.L.

    2012-01-01

    Highlights: ► This paper reports a novel 27-level DC–AC inverter using only single renewable energy source. ► The efficiency of the inverter is very high. The output waveform is almost sinusoidal. ► The cost is low as the number of power switches required is only 12. - Abstract: A novel design of multilevel DC–AC inverter using only single renewable energy source is presented in this paper. The proposed approach enables multilevel output to be realised by a few cascaded H-bridges and a single energy source. As an illustration, a 27-level inverter has been implemented based on three cascaded H-bridges with a single energy source and two capacitors. Using the proposed novel switching strategy, 27 levels can be realized and the two virtual energy sources can be well regulated. Experimental results are included to demonstrate the effectiveness of the proposed inverter.

  18. The role of grid-connected, building-integrated photovoltaic generation in commercial building energy and power loads in a warm and sunny climate

    International Nuclear Information System (INIS)

    Braun, P.; Ruether, R.

    2010-01-01

    For large commercial buildings, power load delivery limits are contracted with the local electricity distribution utility, and are usually fixed at one or more levels over the year, according to the seasonal building loads, and depending on the specific country regulations. Especially in warm and sunny climates, solar electricity generation using building-integrated photovoltaics (BIPV) can assist in reducing commercial building loads, offering peak-shaving (power) benefits on top of the on-site generation of electricity (energy). This on-site power delivery capability gives these consumers the possibility of renegotiating demand contracts with their distribution utility. Commercial buildings that operate during daytime quite often have an energy consumption profile that is well matched by solar radiation availability, and depending on the building's available surface areas, BIPV can generate considerable portions of the energy requirements. In this work we present the role of grid-connected BIPV in reducing the load demands of a large and urban commercial building located in a warm climate in Brazil. The building and adjacent car parking lots can accommodate a 1 MWp BIPV generator, which closely matches the building's typical maximum power demands. Based on real solar radiation data and simultaneous building electricity demands for the year 2007, simulation of the annual solar generation profile of this on-site generator showed that the 1 MWp BIPV system could account for around 30% of the total building's energy consumption. In addition to the energy benefit, maximum power demands were reduced due to a good match between midday air-conditioning cooling loads and solar radiation availability on both a daily and seasonal basis. Furthermore, we have simulated the effect of this considerably large urban-sited generator on the local distribution network load, and have shown that the 1 MWp BIPV installation can also offer considerable benefits to the local utility in

  19. Power flow control strategy in distribution network for dc type distributed energy resource at load bus

    International Nuclear Information System (INIS)

    Hanif, A.; Choudhry, M.A.

    2013-01-01

    This research work presents a feed forward power flow control strategy in the secondary distribution network working in parallel with a DC type distributed energy resource (DER) unit with SPWM-IGBT Voltage Source Converter (VSC). The developed control strategy enables the VSC to be used as power flow controller at the load bus in the presence of utility supply. Due to the investigated control strategy, power flow control from distributed energy resource (DER) to common load bus is such that power flows to the load without facing any power quality problem. The technique has an added advantage of controlling power flow without having a dedicated power flow controller. The SPWM-IGBT VSC is serving the purpose of dc-ac converter as well as power flow controller. Simulations for a test system using proposed power flow control strategy are carried out using SimPower Systems toolbox of MATLAB at the rate and Simulink at the rate. The results show that a reliable, effective and efficient operation of DC type DER unit in coordination with main utility network can be achieved. (author)

  20. Economic levels of thermal resistance for house envelopes: Considerations for a national energy code

    International Nuclear Information System (INIS)

    Swinton, M.C.; Sander, D.M.

    1992-01-01

    A code for energy efficiency in new buildings is being developed by the Standing Committee on Energy Conservation in Buildings. The precursor to the new code used national average energy rates and construction costs to determine economic optimum levels of insulation, and it is believed that this resulted in prescription of sub-optimum insulation levels in any region of Canada where energy or construction costs differ significantly from the average. A new approach for determining optimum levels of thermal insulation is proposed. The analytic techniques use month-by-month energy balances of heat loss and gain; use gain load ratio correlation (GLR) for predicting the fraction of useable free heat; increase confidence in the savings predictions for above grade envelopes; can take into account solar effects on windows; and are compatible with below-grade heat loss analysis techniques in use. A sensitivity analysis was performed to determine whether reasonable variations in house characteristics would cause significant differences in savings predicted. The life cycle costing technique developed will allow the selection of thermal resistances that are commonly met by industry. Environmental energy cost multipliers can be used with the proposed methodology, which could have a minor role in encouraging the next higher level of energy efficiency. 11 refs., 6 figs., 2 tabs

  1. Transient modelling of heat loading of phase change material for energy storage

    Directory of Open Access Journals (Sweden)

    Asyraf W.M.

    2017-01-01

    Full Text Available As the development of solar energy is getting advance from time to time, the concentration solar technology also get the similar attention from the researchers all around the globe. This technology concentrate a large amount of energy into main spot. To collect all the available energy harvest from the solar panel, a thermal energy storage is required to convert the heat energy to one of the purpose such as electrical energy. With the idea of energy storage application that can be narrow down to commercial application such as cooking stove. Using latent heat type energy storage seem to be appropriate with the usage of phase change material (PCM that can release and absorb heat energy at nearly constant temperature by changing its state. Sodium nitrate (NaNO3 and potassium nitrate (KNO3 was selected to use as PCM in this project. This paper focus on the heat loading process and the melting process of the PCM in the energy storage using a computer simulation. The model of the energy storage was created as solid three dimensional modelling using computer aided software and the geometry size of it depend on how much it can apply to boil 1 kg of water in cooking application. The materials used in the tank, heat exchanger and the heat transfer fluid are stainless steel, copper and XCELTHERM MK1, respectively. The analysis was performed using a commercial simulation software in a transient state. The simulation run on different value of velocity but kept controlled under laminar state only, then the relationship of velocity and heat distribution was studied and the melting process of the PCM also has been analyzed. On the effect of heat transfer fluid velocity, the higher the velocity resulted in higher the rate of heat transfer. The comparison between the melting percentages of the PCMs under test conditions show that NaNO3 melts quite faster than KNO3.

  2. Dietary energy level for optimum productivity and carcass ...

    African Journals Online (AJOL)

    user

    2013-08-05

    Aug 5, 2013 ... optimum weights at dietary energy levels of 13.81, 13.23, 13.43 and ... Tadelle & Ogle (2000) reported that energy requirement of ..... The authors would like to acknowledge the National Research Foundation (NRF) and VLIR ...

  3. Energy levels of germanium, Ge I through Ge XXXII

    International Nuclear Information System (INIS)

    Sugar, J.; Musgrove, A.

    1993-01-01

    Atomic energy levels of germanium have been compiled for all stages of ionization for which experimental data are available. No data have yet been published for Ge VIII through Ge XIII and Ge XXXII. Very accurate calculated values are compiled for Ge XXXI and XXXII. Experimental g-factors and leading percentages from calculated eigenvectors of levels are given. A value for the ionization energy, either experimental when available or theoretical, is included for the neutral atom and each ion. section

  4. Vibration and Energy Dissipation of Nanocomposite Laminates for Below Ballistic Impact Loading

    Directory of Open Access Journals (Sweden)

    G. Balaganesan

    Full Text Available Abstract Composite laminates are made of glass woven roving mats of 610gsm, epoxy resin and nano clay which are subjected to projectile impact. Nano clay dispersion is varied from 1% to 5%. Impact tests are conducted in a gas gun setup with a spherical nose cylindrical projectile of diameter 9.5 mm of mass 7.6 g. The energy absorbed by the laminates when subjected to impact loading is studied, the velocity range is below ballistic limit. The effect of nano clay on energy absorption in vibration, delamination and matrix crack is studied for different weight % of nano clay and for different thickness values of the laminates. The natural frequencies and damping factors are obtained for the laminates during impact and the effect of nano clay is studied. The results show considerable improvement in energy absorption due to the presence of nano clay

  5. Experimental Characterization of the Energy Absorption of Functionally Graded Foam Filled Tubes Under Axial Crushing Loads

    Science.gov (United States)

    Ebrahimi, Saeed; Vahdatazad, Nader; Liaghat, Gholamhossein

    2018-03-01

    This paper deals with the energy absorption characterization of functionally graded foam (FGF) filled tubes under axial crushing loads by experimental method. The FGF tubes are filled axially by gradient layers of polyurethane foams with different densities. The mechanical properties of the polyurethane foams are firstly obtained from axial compressive tests. Then, the quasi-static compressive tests are carried out for empty tubes, uniform foam filled tubes and FGF filled tubes. Before to present the experimental test results, a nonlinear FEM simulation of the FGF filled tube is carried out in ABAQUS software to gain more insight into the crush deformation patterns, as well as the energy absorption capability of the FGF filled tube. A good agreement between the experimental and simulation results is observed. Finally, the results of experimental test show that an FGF filled tube has excellent energy absorption capacity compared to the ordinary uniform foam-filled tube with the same weight.

  6. Evaluation of Renal Oxygenation Level Changes after Water Loading Using Susceptibility-Weighted Imaging and T2* Mapping.

    Science.gov (United States)

    Ding, Jiule; Xing, Wei; Wu, Dongmei; Chen, Jie; Pan, Liang; Sun, Jun; Xing, Shijun; Dai, Yongming

    2015-01-01

    To assess the feasibility of susceptibility-weighted imaging (SWI) while monitoring changes in renal oxygenation level after water loading. Thirty-two volunteers (age, 28.0 ± 2.2 years) were enrolled in this study. SWI and multi-echo gradient echo sequence-based T2(*) mapping were used to cover the kidney before and after water loading. Cortical and medullary parameters were measured using small regions of interest, and their relative changes due to water loading were calculated based on baseline and post-water loading data. An intraclass correlation coefficient analysis was used to assess inter-observer reliability of each parameter. A receiver operating characteristic curve analysis was conducted to compare the performance of the two methods for detecting renal oxygenation changes due to water loading. Both medullary phase and medullary T2(*) values increased after water loading (p T2(*) changes (p > 0.05). Interobserver reliability was excellent for the T2(*) values, good for SWI cortical phase values, and moderate for the SWI medullary phase values. The area under receiver operating characteristic curve of the SWI medullary phase values was 0.85 and was not different from the medullary T2(*) value (0.84). Susceptibility-weighted imaging enabled monitoring changes in the oxygenation level in the medulla after water loading, and may allow comparable feasibility to detect renal oxygenation level changes due to water loading compared with that of T2(*) mapping.

  7. Loading forces in shallow water running in two levels of immersion.

    Science.gov (United States)

    Haupenthal, Alessandro; Ruschel, Caroline; Hubert, Marcel; de Brito Fontana, Heiliane; Roesler, Helio

    2010-07-01

    To analyse the vertical and anteroposterior components of the ground reaction force during shallow water running at 2 levels of immersion. Twenty-two healthy adults with no gait disorders, who were familiar with aquatic exercises. Subjects performed 6 trials of water running at a self-selected speed in chest and hip immersion. Force data were collected through an underwater force plate and running speed was measured with a photocell timing light system. Analysis of covariance was used for data analysis. Vertical forces corresponded to 0.80 and 0.98 times the subject's body weight at the chest and hip level, respectively. Anteroposterior forces corresponded to 0.26 and 0.31 times the subject's body weight at the chest and hip level, respectively. As the water level decreased the subjects ran faster. No significant differences were found for the force values between the immersions, probably due to variability in speed, which was self-selected. When thinking about load values in water running professionals should consider not only the immersion level, but also the speed, as it can affect the force components, mainly the anteroposterior one. Quantitative data on this subject could help professionals to conduct safer aqua-tic rehabilitation and physical conditioning protocols.

  8. Performance improvement of a battery/PV/fuel cell/grid hybrid energy system considering load uncertainty modeling using IGDT

    International Nuclear Information System (INIS)

    Nojavan, Sayyad; Majidi, Majid; Zare, Kazem

    2017-01-01

    Highlights: • Optimum performance of PV/battery/fuel cell/grid hybrid system under load uncertainty. • Employing information gap decision theory (IGDT) to model the load uncertainty. • Robustness and opportunity functions of IGDT are modeled for risk-averse and risk-taker. • Robust strategy of hybrid system's operation obtained from robustness function. • Opportunistic strategy of hybrid system's operation obtained from opportunity function. - Abstract: Nowadays with the speed that electrical loads are growing, system operators are challenged to manage the sources they use to supply loads which means that that besides upstream grid as the main sources of electric power, they can utilize renewable and non-renewable energy sources to meet the energy demand. In the proposed paper, a photovoltaic (PV)/fuel cell/battery hybrid system along with upstream grid has been utilized to supply two different types of loads: electrical load and thermal load. Operators should have to consider load uncertainty to manage the strategies they employ to supply load. In other words, operators have to evaluate how load variation would affect their energy procurement strategies. Therefore, information gap decision theory (IGDT) technique has been proposed to model the uncertainty of electrical load. Utilizing IGDT approach, robustness and opportunity functions are achieved which can be used by system operator to take the appropriate strategy. The uncertainty modeling of load enables operator to make appropriate decisions to optimize the system’s operation against possible changes in load. A case study has been simulated to validate the effects of proposed technique.

  9. Solar energy storage in German households: profitability, load changes and flexibility

    International Nuclear Information System (INIS)

    Kaschub, Thomas; Jochem, Patrick; Fichtner, Wolf

    2016-01-01

    The developments of battery storage technology together with photovoltaic (PV) roof-top systems might lead to far-reaching changes in the electricity demand structures and flexibility of households. The implications are supposed to affect the generation mix of utilities, distribution grid utilization, and electricity price. Using a techno-economic optimization model of a household system, we endogenously dimension PV system and stationary battery storage (SBS). The results of the reference scenario show positive net present values (NPV) for PV systems of approx. 500–1,800 EUR/kW_p and NPV for SBS of approx. 150–500 EUR/kWh. Main influences are the demand of the households, self-consumption rates, investment costs, and electricity prices. We integrate electric vehicles (EV) with different charging strategies and find increasing NPV of the PV system and self-consumption of approx. 70%. With further declining system prices for solar energy storage and increasing electricity prices, PV systems and SBS can be profitable in Germany from 2018 on even without a guaranteed feed-in tariff or subsidies. Grid utilization substantially changes by households with EV and PV-SBS. We discuss effects of different incentives and electricity tariff options (e. g. load limits or additional demand charges). Concluding, solar energy storage systems will bring substantial changes to electricity sales. - Highlights: • Domestic photovoltaics (PV) and storage systems are techno-economically analyzed. • PV & storage are profitable in the medium term due to high self-consumption rates. • Controlled electric vehicle charging improves load flexibility and self-generation. • External procurement of electricity drastically changes and decreases to 48–58%. • Dynamic tariffs e. g. with load limits or demand charges incentivize load shifting.

  10. Benzo[a]pyrene in urban environments of eastern Moscow: pollution levels and critical loads

    Science.gov (United States)

    Kasimov, Nikolay S.; Kosheleva, Natalia E.; Nikiforova, Elena M.; Vlasov, Dmitry V.

    2017-02-01

    Polycyclic aromatic hydrocarbons (PAHs), particularly benzo[a]pyrene (BaP), are toxic compounds emitted from various anthropogenic sources. Understanding the BaP concentrations, dynamics and decomposition in soil is required to assess the critical loads of BaP in urban environments. This study is the first attempt to evaluate all major input and output components of benzo[a]pyrene (BaP) balance and to calculate the permissible load on the urban environment in different land-use zones in the Eastern district of Moscow. BaP contamination of the snow cover in the Eastern district of Moscow was related to daily BaP fallout from the atmosphere. In 2010, the mean content of the pollutant in the snow dust was 1942 ng g-1, whereas the average intensity of its fallout was 7.13 ng m-2 per day. Across the territory, BaP winter fallout intensities varied from 0.3 to 1100 ng m-2 per day. The average BaP content in the surface (0-10 cm) soil horizons was 409 ng g-1, which is 83 times higher than the local background value and 20 times higher than the maximum permissible concentration (MPC) accepted in Russia. The variations in soil and snow BaP concentrations among different land-use zones were examined. A significant contribution of BaP from the atmosphere to urban soils was identified. Based on the measurements of BaP atmospheric fallout and BaP reserves in the soils, the critical loads of BaP for the land-use zones in the Eastern district were calculated for different values of degradation intensity and different exposure times. It was established that at an annual degradation intensity of 1-10 %, ecologically safe BaP levels in the soils of all land-use zones, excluding the agricultural zone, will only be reached after many decades or centuries.

  11. New energy levels of praseodymium with large angular momentum

    Energy Technology Data Exchange (ETDEWEB)

    Khan, Shamim; Siddiqui, Imran; Gamper, Bettina; Syed, Tanweer Iqbal; Guthoehrlein, Guenter H.; Windholz, Laurentius [Inst. f. Experimentalphysik, Techn. Univ. Graz, Petersgasse 16, A-8010 Graz (Austria)

    2011-07-01

    The electronic ground state configuration of praseodymium {sup 59}Pr{sub 141} is [Xe] 4f{sup 3}6s{sup 2}, with ground state level {sup 4}I{sub 9/2}. Our research is mainly devoted to find previously unknown energy levels by the investigation of spectral lines and their hyperfine structures. In a hollow cathode discharge lamp praseodymium atoms and ions in ground and excited states are excited to high lying states by laser light. The excitation source is a tunable ring-dye laser system, operated with R6G, Kiton Red, DCM and LD700. A high resolution Fourier transform spectrum is used for selecting promising excitation wavelengths. Then the laser wavelength is tuned to a strong hyperfine component of the spectral line to be investigated, and a search for fluorescence from excited levels is performed. From the observed hyperfine structure we determine J-values and hyperfine constants A of the combining levels. This information, together with excitation and fluorescence wavelengths, allows us to find the energies of involved new levels. Up to now we have discovered large number of previously unknown energy levels with various angular momentum values. We present here the data (energies, parities, angular momenta J, magnetic hyperfine constants A) of ca. 40 new, until now unknown energy levels with high angular momentum values: 15/2, 17/2, 19/2, 21/2.

  12. A Source-level Energy Optimization Framework for Mobile Applications

    DEFF Research Database (Denmark)

    Li, Xueliang; Gallagher, John Patrick

    2016-01-01

    strategies. The framework also lays a foundation for the code optimization by automatic tools. To the best of our knowledge, our work is the first that achieves this for a high-level language such as Java. In a case study, the experimental evaluation shows that our approach is able to save from 6.4% to 50...... process. The source code is the interface between the developer and hardware resources. In this paper, we propose an energy optimization framework guided by a source code energy model that allows developers to be aware of energy usage induced by the code and to apply very targeted source-level refactoring...

  13. Temperature dependent energy levels of methylammonium lead iodide perovskite

    Science.gov (United States)

    Foley, Benjamin J.; Marlowe, Daniel L.; Sun, Keye; Saidi, Wissam A.; Scudiero, Louis; Gupta, Mool C.; Choi, Joshua J.

    2015-06-01

    Temperature dependent energy levels of methylammonium lead iodide are investigated using a combination of ultraviolet photoemission spectroscopy and optical spectroscopy. Our results show that the valence band maximum and conduction band minimum shift down in energy by 110 meV and 77 meV as temperature increases from 28 °C to 85 °C. Density functional theory calculations using slab structures show that the decreased orbital splitting due to thermal expansion is a major contribution to the experimentally observed shift in energy levels. Our results have implications for solar cell performance under operating conditions with continued sunlight exposure and increased temperature.

  14. Temperature dependent energy levels of methylammonium lead iodide perovskite

    Energy Technology Data Exchange (ETDEWEB)

    Foley, Benjamin J.; Marlowe, Daniel L.; Choi, Joshua J., E-mail: jjc6z@virginia.edu, E-mail: mgupta@virginia.edu, E-mail: scudiero@wsu.edu [Department of Chemical Engineering, University of Virginia, Charlottesville, Virginia 22904 (United States); Sun, Keye; Gupta, Mool C., E-mail: jjc6z@virginia.edu, E-mail: mgupta@virginia.edu, E-mail: scudiero@wsu.edu [Department of Electrical and Computer Engineering, University of Virginia, Charlottesville, Virginia 22904 (United States); Saidi, Wissam A. [Department of Mechanical Engineering and Materials Science, University of Pittsburgh, Pittsburgh, Pennsylvania 15261 (United States); Scudiero, Louis, E-mail: jjc6z@virginia.edu, E-mail: mgupta@virginia.edu, E-mail: scudiero@wsu.edu [Chemistry Department and Materials Science and Engineering Program, Washington State University, Pullman, Washington 99164 (United States)

    2015-06-15

    Temperature dependent energy levels of methylammonium lead iodide are investigated using a combination of ultraviolet photoemission spectroscopy and optical spectroscopy. Our results show that the valence band maximum and conduction band minimum shift down in energy by 110 meV and 77 meV as temperature increases from 28 °C to 85 °C. Density functional theory calculations using slab structures show that the decreased orbital splitting due to thermal expansion is a major contribution to the experimentally observed shift in energy levels. Our results have implications for solar cell performance under operating conditions with continued sunlight exposure and increased temperature.

  15. Energy conversion through mass loading of escaping ionospheric ions for different Kp values

    Directory of Open Access Journals (Sweden)

    M. Yamauchi

    2018-01-01

    Full Text Available By conserving momentum during the mixing of fast solar wind flow and slow planetary ion flow in an inelastic way, mass loading converts kinetic energy to other forms – e.g. first to electrical energy through charge separation and then to thermal energy (randomness through gyromotion of the newly born cold ions for the comet and Mars cases. Here, we consider the Earth's exterior cusp and plasma mantle, where the ionospheric origin escaping ions with finite temperatures are loaded into the decelerated solar wind flow. Due to direct connectivity to the ionosphere through the geomagnetic field, a large part of this electrical energy is consumed to maintain field-aligned currents (FACs toward the ionosphere, in a similar manner as the solar wind-driven ionospheric convection in the open geomagnetic field region. We show that the energy extraction rate by the mass loading of escaping ions (ΔK is sufficient to explain the cusp FACs, and that ΔK depends only on the solar wind velocity accessing the mass-loading region (usw and the total mass flux of the escaping ions into this region (mloadFload, as ΔK ∼ −mloadFloadu2sw∕4. The expected distribution of the separated charges by this process also predicts the observed flowing directions of the cusp FACs for different interplanetary magnetic field (IMF orientations if we include the deflection of the solar wind flow directions in the exterior cusp. Using empirical relations of u0 ∝ Kp + 1.2 and Fload ∝ exp(0.45Kp for Kp = 1–7, where u0 is the solar wind velocity upstream of the bow shock, ΔK becomes a simple function of Kp as log10(ΔK = 0.2 ⋅ Kp + 2 ⋅ log10(Kp + 1.2 + constant. The major contribution of this nearly linear increase is the Fload term, i.e. positive feedback between the increase of ion escaping rate Fload through the increased energy consumption in the ionosphere for high Kp, and subsequent extraction of more kinetic energy

  16. Energy Coordinative Optimization of Wind-Storage-Load Microgrids Based on Short-Term Prediction

    Directory of Open Access Journals (Sweden)

    Changbin Hu

    2015-02-01

    Full Text Available According to the topological structure of wind-storage-load complementation microgrids, this paper proposes a method for energy coordinative optimization which focuses on improvement of the economic benefits of microgrids in the prediction framework. First of all, the external characteristic mathematical model of distributed generation (DG units including wind turbines and storage batteries are established according to the requirements of the actual constraints. Meanwhile, using the minimum consumption costs from the external grid as the objective function, a grey prediction model with residual modification is introduced to output the predictive wind turbine power and load at specific periods. Second, based on the basic framework of receding horizon optimization, an intelligent genetic algorithm (GA is applied to figure out the optimum solution in the predictive horizon for the complex non-linear coordination control model of microgrids. The optimum results of the GA are compared with the receding solution of mixed integer linear programming (MILP. The obtained results show that the method is a viable approach for energy coordinative optimization of microgrid systems for energy flow and reasonable schedule. The effectiveness and feasibility of the proposed method is verified by examples.

  17. Load shifting with the use of home energy management system implemented in FPGA

    Science.gov (United States)

    Bazydło, Grzegorz; Wermiński, Szymon

    2017-08-01

    The increases for power demand in the Electrical Power System (EPS) causes a significant increase of power in daily load curve and transmission line overload. The large variability in energy consumption in EPS combined with unpredictable weather events can lead to a situation in which to save the stability of the EPS, the power limits must be introduced or even industrial customers in a given area have to be disconnected, which causes financial losses. Nowadays, a Transmission System Operator is looking for additional solutions to reduce peak power, because existing approaches (mainly building new intervention power unit or tariff programs) are not satisfactory due to the high cost of services in combination with insufficient power reduction effect. The paper presents an approach to load shifting with the use of home Energy Management System (EMS) installed at small end-users. The home energy management algorithm, executed by EMS controller, is modeled using Unified Modeling Language (UML). Then, the UML model is translated into Verilog description, and is finally implemented in the Field Programmable Gate Arrays. The advantages of the proposed approach are the relatively low cost of reduction service, small loss of end-users' comfort, and the convenient maintenance of EMS. A practical example illustrating the proposed approach and calculation of potential gains from its implementation are also presented.

  18. Loaded and unloaded jump performance of top-level volleyball players from different age categories

    Science.gov (United States)

    Kitamura, Katia; Pereira, Lucas Adriano; Kobal, Ronaldo; Cal Abad, Cesar Cavinato; Finotti, Ronaldo; Nakamura, Fábio Yuzo

    2017-01-01

    The aim of this study was to investigate the differences in loaded and unloaded jump performances between different age categories of top-level volleyball players from the same club. Forty-three volleyball players were divided into four age groups: under-17, under-19, under-21 and professional. Vertical jumping height for squat jump (SJ), countermovement jump (CMJ) and CMJ with arm swing (CMJa) and mean propulsive velocity (MPV) in the loaded jump squat exercise with 40% of the athlete’s body mass were compared among the different age categories, considering body mass as a covariate. SJ and CMJ jump height values were higher for professional and under-21 players than under-17 players (pvolleyball players. Therefore, to increase the vertical jumping ability of these team sport athletes throughout their long-term development, coaches and strength and conditioning professionals are encouraged to implement consistent neuromuscular training strategies, in accordance with the specific needs and physiological characteristics of each age group. PMID:29158621

  19. Energy Efficient Cooperative Spectrum Sensing in Cognitive Radio Networks Using Distributed Dynamic Load Balanced Clustering Scheme

    Directory of Open Access Journals (Sweden)

    Muthukkumar R.

    2017-04-01

    Full Text Available Cognitive Radio (CR is a promising and potential technique to enable secondary users (SUs or unlicenced users to exploit the unused spectrum resources effectively possessed by primary users (PUs or licenced users. The proven clustering approach is used to organize nodes in the network into the logical groups to attain energy efficiency, network scalability, and stability for improving the sensing accuracy in CR through cooperative spectrum sensing (CSS. In this paper, a distributed dynamic load balanced clustering (DDLBC algorithm is proposed. In this algorithm, each member in the cluster is to calculate the cooperative gain, residual energy, distance, and sensing cost from the neighboring clusters to perform the optimal decision. Each member in a cluster participates in selecting a cluster head (CH through cooperative gain, and residual energy that minimises network energy consumption and enhances the channel sensing. First, we form the number of clusters using the Markov decision process (MDP model to reduce the energy consumption in a network. In this algorithm, CR users effectively utilize the PUs reporting time slots of unavailability. The simulation results reveal that the clusters convergence, energy efficiency, and accuracy of channel sensing increased considerably by using the proposed algorithm.

  20. Energy Efficient Cooperative Spectrum Sensing in Cognitive Radio Networks Using Distributed Dynamic Load Balanced Clustering Scheme

    Directory of Open Access Journals (Sweden)

    Muthukkumar R.

    2016-07-01

    Full Text Available Cognitive Radio (CR is a promising and potential technique to enable secondary users (SUs or unlicenced users to exploit the unused spectrum resources effectively possessed by primary users (PUs or licenced users. The proven clustering approach is used to organize nodes in the network into the logical groups to attain energy efficiency, network scalability, and stability for improving the sensing accuracy in CR through cooperative spectrum sensing (CSS. In this paper, a distributed dynamic load balanced clustering (DDLBC algorithm is proposed. In this algorithm, each member in the cluster is to calculate the cooperative gain, residual energy, distance, and sensing cost from the neighboring clusters to perform the optimal decision. Each member in a cluster participates in selecting a cluster head (CH through cooperative gain, and residual energy that minimises network energy consumption and enhances the channel sensing. First, we form the number of clusters using the Markov decision process (MDP model to reduce the energy consumption in a network. In this algorithm, CR users effectively utilize the PUs reporting time slots of unavailability. The simulation results reveal that the clusters convergence, energy efficiency, and accuracy of channel sensing increased considerably by using the proposed algorithm.

  1. Definition of Static Voltage Characteristics of the Motor Load for the Purpose of Increase in Energy Efficiency of Coal Mines of Kuzbass

    Science.gov (United States)

    Nepsha, Fedor; Efremenko, Vladimir

    2017-11-01

    The task of determining the static load characteristics is one of the most important tasks, the solution of which is necessary for the correct development of measures to increase the energy efficiency of the Kuzbass coal mines. At present, the influence of electric receivers on the level of consumption of active and reactive power is not taken into account, therefore, the proposed measures to increase the energy efficiency are not optimal. The article analyzes the L-shaped and T-shaped circuit for the replacement of an asynchronous motor (AM), according to the results of which it is determined that the T-shaped replacement scheme is the most accurate for determination of static load characteristics. The authors proposed and implemented in the MATLAB Simulink environment an algorithm for determining the static voltage characteristics of the motor load.

  2. Energy index decomposition methodology at the plant level

    Science.gov (United States)

    Kumphai, Wisit

    Scope and method of study. The dissertation explores the use of a high level energy intensity index as a facility-level energy performance monitoring indicator with a goal of developing a methodology for an economically based energy performance monitoring system that incorporates production information. The performance measure closely monitors energy usage, production quantity, and product mix and determines the production efficiency as a part of an ongoing process that would enable facility managers to keep track of and, in the future, be able to predict when to perform a recommissioning process. The study focuses on the use of the index decomposition methodology and explored several high level (industry, sector, and country levels) energy utilization indexes, namely, Additive Log Mean Divisia, Multiplicative Log Mean Divisia, and Additive Refined Laspeyres. One level of index decomposition is performed. The indexes are decomposed into Intensity and Product mix effects. These indexes are tested on a flow shop brick manufacturing plant model in three different climates in the United States. The indexes obtained are analyzed by fitting an ARIMA model and testing for dependency between the two decomposed indexes. Findings and conclusions. The results concluded that the Additive Refined Laspeyres index decomposition methodology is suitable to use on a flow shop, non air conditioned production environment as an energy performance monitoring indicator. It is likely that this research can be further expanded in to predicting when to perform a recommissioning process.

  3. Load Frequency Control of Two-Area Network using Renewable Energy Resources and Battery Energy Storage System

    Directory of Open Access Journals (Sweden)

    Norhafiz Bin SALIM

    2017-06-01

    Full Text Available In an interconnected system, the frequency and tie-line power interchange are very susceptible with the diversification of power load demand. Literally, in a multi-area power system, the load frequency control (LFC is substantially aimed to minimise the deviations of these parameters relatively. Knowingly, the power production from renewable energy resources could offer promising solutions despite their intermittency (i.e. photovoltaic/wind generation, hence in this context, a battery energy storage system (BESS is proposed to delineate dynamic response along with grid—connection. This study has proposed LFC with BESS control method to suppress frequency deviations for a power system and being compared with photovoltaic (PV approach. The effectiveness was verified using newly developed AGC30 model of Japanese Power System and was modelled using MATLAB Simulink. Furthermore, an analysis of the tie-line power oscillations also are carried out and comparison analysis demonstrates further the reliability of the proposed model and control methods.

  4. Dual-Level Game-Based Energy Efficiency and Fairness for Green Cellular Networks

    Directory of Open Access Journals (Sweden)

    Sungwook Kim

    2016-01-01

    Full Text Available In the recent decades, cellular networks have revolutionized the way of next generation communication networks. However, due to the global climate change, reducing the energy consumption of cellular infrastructures is an important and urgent problem. In this study, we propose a novel two-level cooperative game framework for improving the energy efficiency and fairness in cellular networks. For the energy efficiency, base stations (BSs constantly monitor the current traffic load and cooperate with each other to maximize the energy saving. For the energy fairness, renewable energy can be shared dynamically while ensuring the fairness among BSs. To achieve an excellent cellular network performance, the concepts of the Raiffa Bargaining Solution and Jain’s fairness are extended and practically applied to our dual-level cooperative game model. Through system level simulations, the proposed scheme is evaluated and compared with other existing schemes. The simulation results show that our two-level game approach outperforms the existing schemes in providing a better fair-efficient system performance.

  5. Electron Energy Level Statistics in Graphene Quantum Dots

    NARCIS (Netherlands)

    De Raedt, H.; Katsnellson, M. I.; Katsnelson, M.I.

    2008-01-01

    Motivated by recent experimental observations of size quantization of electron energy levels in graphene quantum dots [7] we investigate the level statistics in the simplest tight-binding model for different dot shapes by computer simulation. The results are in a reasonable agreement with the

  6. Spin energy levels in axial symmetry: spin 4

    Energy Technology Data Exchange (ETDEWEB)

    de Biasi, R S; Portella, P D [Instituto Militar de Engenharia, Rio de Janeiro (Brazil). Secao de Engenharia e Ciencia dos Materiais

    1979-01-01

    The spin energy levels in axial symmetry are presented, in graphical and tabular form, for a spin 4. The levels are calculated for five different angles between the applied field and the symmetry axis 0/sup 0/, 30/sup 0/, 45/sup 0/, 60 and 90/sup 0/.

  7. Spin energy levels in axial symmetry: spin 3/2

    Energy Technology Data Exchange (ETDEWEB)

    de Biasi, R S; Portella, P D [Instituto Militar de Engenharia, Rio de Janeiro (Brazil). Secao de Engenharia e Ciencia dos Materiais

    1977-01-01

    The spin energy levels in axial symmetry are presented, in graphical and tabular form, for a spin 3/2. The levels are calculated for five different angles between the applied field and the symmetry axis: 0/sup 0/, 30/sup 0/, 45/sup 0/, 60/sup 0/ and 90/sup 0/.

  8. Adaptive algorithm for predicting increases in central loads of electrical energy systems

    Energy Technology Data Exchange (ETDEWEB)

    Arbachyauskene, N A; Pushinaytis, K V

    1982-01-01

    An adaptive algorithm for predicting increases in central loads of the electrical energy system is suggested for the task of evaluating the condition. The algorithm is based on the Kalman filter. In order to calculate the coefficient of intensification, the a priori assigned noise characteristics with low accuracy are used only in the beginning of the calculation. Further, the coefficient of intensification is calculated from the innovation sequence. This approach makes it possible to correct errors in the assignment of the statistical noise characteristics and to follow their changes. The algorithm is experimentally verified.

  9. Research into the Energy Output of Asymmetric Cylindrical Structure under Internal Explosion Loading

    Directory of Open Access Journals (Sweden)

    Liangliang Ding

    2018-04-01

    Full Text Available The energy output characteristic of an asymmetric cylindrical structure under internal explosion loading has significant research value in the field of the national defense industry. This paper took the D-shaped structure as the research object. Three groups of experiments (D-90°, D-120°, D-150° were carried out. The D-shaped structure showed that fragments are concentrated in the middle and are sparse on both sides. Moreover, the fragment density decreased with the increase of the azimuth angle. The fragment velocities, which were measured from high-speed photography and an oscilloscope, coincided well with each other, and decreased with an increase in the central angle. Compared with the cylindrical structure, the fragment energy gain of the D-shaped structure is significant; the total energy and energy density of the three D-shaped structures were very close to each other. This indicates that D-120° is the optimal solution among the three D-shaped structures and it can provide guidance for the future design of D-shaped structures to achieve higher energy output.

  10. Real-Time Vehicle Energy Management System Based on Optimized Distribution of Electrical Load Power

    Directory of Open Access Journals (Sweden)

    Yuefei Wang

    2016-10-01

    Full Text Available As a result of severe environmental pressure and stringent government regulations, refined energy management for vehicles has become inevitable. To improve vehicle fuel economy, this paper presents a bus-based energy management system for the electrical system of internal combustion engine vehicles. Both the model of an intelligent alternator and the model of a lead-acid battery are discussed. According to these models, the energy management for a vehicular electrical system is formulated as a global optimal control problem which aims to minimize fuel consumption. Pontryagin’s minimum principle is applied to solve the optimal control problem to realize a real-time control strategy for electrical energy management in vehicles. The control strategy can change the output of the intelligent alternator and the battery with the changes of electrical load and driving conditions in real-time. Experimental results demonstrate that, compared to the traditional open-loop control strategy, the proposed control strategy for vehicle energy management can effectively reduce fuel consumption and the fuel consumption per 100 km is decreased by approximately 1.7%.

  11. Research on Power System Scheduling Improving Wind Power Accommodation Considering Thermal Energy Storage and Flexible Load

    Science.gov (United States)

    Zou, Chenlu; Cui, Xue; Wang, Heng; Zhou, Bin; Liu, Yang

    2018-01-01

    In the case of rapid development of wind power and heavy wind curtailment, the study of wind power accommodation of combined heat and power system has become the focus of attention. A two-stage scheduling model contains of wind power, thermal energy storage, CHP unit and flexible load were constructed. This model with the objective function of minimizing wind curtailment and the operation cost of units while taking into account of the total coal consumption of units, constraint of thermal energy storage and electricity-heat characteristic of CHP. This paper uses MICA to solve the problem of too many constraints and make the solution more feasible. A numerical example showed that the two stage decision scheduling model can consume more wind power, and it could provide a reference for combined heat and power system short-term operation

  12. Advances in electric power and energy systems load and price forecasting

    CERN Document Server

    2017-01-01

    A comprehensive review of state-of-the-art approaches to power systems forecasting from the most respected names in the field, internationally. Advances in Electric Power and Energy Systems is the first book devoted exclusively to a subject of increasing urgency to power systems planning and operations. Written for practicing engineers, researchers, and post-grads concerned with power systems planning and forecasting, this book brings together contributions from many of the world’s foremost names in the field who address a range of critical issues, from forecasting power system load to power system pricing to post-storm service restoration times, river flow forecasting, and more. In a time of ever-increasing energy demands, mounting concerns over the environmental impacts of power generation, and the emergence of new, smart-grid technologies, electricity price forecasting has assumed a prominent role within both the academic and industrial ar nas. Short-run forecasting of electricity prices has become nece...

  13. Study of the energy gain and the beam loading of the detuned structure with a simple model

    International Nuclear Information System (INIS)

    Heifets, S.A.; Kheifets, S.A.

    1993-01-01

    A circuit model for the longitudinal case from which to study the field pattern, energy gain and beam loading of a detuned structure is derived from Maxwell's equations. The results obtained with the model are compared to numerical results of the code PROGON. The model gives reasonable scaling of the group velocity and voltage with geometric parameters. The energy gain and beam loading are compared and are shown to depend on the same factor. This is true even for periodic variations of the boundary. Finally, a way to find the shape of the rf pulse envelope for the beam loading compensation is suggested

  14. Approach undertaken by our Company for leveling electric loads; Chubu Denryoku Kabushi Kaisha no fuka heijunka eno torikumi ni tsuite

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-07-01

    Measures for leveling the electric loads relying upon two facets - tariff system and business activities - in Chubu Electric Power Co., Inc. are presented. Firstly, the existing pricing systems for midnight electric power and electric light according to the period of time for the household as well as those of seasonal and time zone electric power, modifiable contract with the time zone and so forth for large industry users, together with a similar contract for the owner of regenerating installation are outlined. In addition, a price reduction system is indicated in favor of a scheduled shutdown of large industry operations as a means of avoiding electric consumption during weekdays in summer and between 13h and 16h when large demands exist. Further, a selective contract system put in service in 1995 and the price reduction for ice regenerating air conditioning system are cited. As for business facet, 1995 is regarded as the first year of the ice regenerator for its generalization through exhibition and promotive campaign to the foods processing industry, and the application of the latent heat regenerative system to perishable foods is recommended. Moreover, installation of energy saving type automatic vending machine, so-called eco-vendor is encouraged for its merit of peak-cut and energy price lowering. Lastly, activities to extend the use of electric calorifiers and the regenerative floor heating are mentioned. 2 figs., 1 tab.

  15. Optimization of waste loading in high-level glass in the presence of uncertainty

    International Nuclear Information System (INIS)

    Hoza, M.; Fann, G.I.; Hopkins, D.F.

    1995-02-01

    Hanford high-level liquid waste will be converted into a glass form for long-term storage. The glass must meet certain constraints on its composition and properties in order to have desired properties for processing (e.g., electrical conductivity, viscosity, and liquidus temperature) and acceptable durability for long-term storage. The Optimal Waste Loading (OWL) models, based on rigorous mathematical optimization techniques, have been developed to minimize the number of glass logs required and determine glass-former compositions that will produce a glass meeting all relevant constraints. There is considerable uncertainty in many of the models and data relevant to the formulation of high-level glass. In this paper, we discuss how we handle uncertainty in the glass property models and in the high-level waste composition to the vitrification process. Glass property constraints used in optimization are inequalities that relate glass property models obtained by regression analysis of experimental data to numerical limits on property values. Therefore, these constraints are subject to uncertainty. The sampling distributions of the regression models are used to describe the uncertainties associated with the constraints. The optimization then accounts for these uncertainties by requiring the constraints to be satisfied within specified confidence limits. The uncertainty in waste composition is handled using stochastic optimization. Given means and standard deviations of component masses in the high-level waste stream, distributions of possible values for each component are generated. A series of optimization runs is performed; the distribution of each waste component is sampled for each run. The resultant distribution of solutions is then statistically summarized. The ability of OWL models to handle these forms of uncertainty make them very useful tools in designing and evaluating high-level waste glasses formulations

  16. Control scheme of three-level H-bridge converter for interfacing between renewable energy resources and AC grid

    DEFF Research Database (Denmark)

    Pouresmaeil, Edris; Montesinos-Miracle, Daniel; Gomis-Bellmunt, Oriol

    2011-01-01

    This paper presents a control strategy of multilevel converters for integration of renewable energy resources into power grid. The proposed technique provides compensation for active, reactive, and harmonic current components of grid-connected loads. A three-level H-bridge converter is proposed a...

  17. Energy-aware hybrid fruitfly optimization for load balancing in cloud environments for EHR applications

    Directory of Open Access Journals (Sweden)

    M. Lawanyashri

    Full Text Available Cloud computing has gained precise attention from the research community and management of IT, due to its scalable and dynamic capabilities. It is evolving as a vibrant technology to modernize and restructure healthcare organization to provide best services to the consumers. The rising demand for healthcare services and applications in cloud computing leads to the imbalance in resource usage and drastically increases the power consumption resulting in high operating cost. To achieve fast execution time and optimum utilization of the virtual machines, we propose a multi-objective hybrid fruitfly optimization technique based on simulated annealing to improve the convergence rate and optimization accuracy. The proposed approach is used to achieve the optimal resource utilization and reduces the energy consumption and cost in cloud computing environment. The result attained in our proposed technique provides an improved solution. The experimental results show that the proposed algorithm efficiently outperforms compared to the existing load balancing algorithms. Keywords: Cloud computing, Electronic Health Records (EHR, Load balancing, Fruitfly Optimization Algorithm (FOA, Simulated Annealing (SA, Energy consumption

  18. Thermal Energy Storage for Building Load Management: Application to Electrically Heated Floor

    Directory of Open Access Journals (Sweden)

    Hélène Thieblemont

    2016-07-01

    Full Text Available In cold climates, electrical power demand for space conditioning becomes a critical issue for utility companies during certain periods of the day. Shifting a portion or all of it to off-peak periods can help reduce peak demand and reduce stress on the electrical grid. Sensible thermal energy storage (TES systems, and particularly electrically heated floors (EHF, can store thermal energy in buildings during the off-peak periods and release it during the peak periods while maintaining occupants’ thermal comfort. However, choosing the type of storage system and/or its configuration may be difficult. In this paper, the performance of an EHF for load management is studied. First, a methodology is developed to integrate EHF in TRNSYS program in order to investigate the impact of floor assembly on the EHF performance. Then, the thermal comfort (TC of the night-running EHF is studied. Finally, indicators are defined, allowing the comparison of different EHF. Results show that an EHF is able to shift 84% of building loads to the night while maintaining acceptable TC in cold climate. Moreover, this system is able to provide savings for the customer and supplier if there is a significant difference between off-peak and peak period electricity prices.

  19. Atomic energy-level and Grotrian diagrams. Vol. 4

    International Nuclear Information System (INIS)

    Bashkin, S.; Stoner, J.O. Jr.

    1982-01-01

    This is the fifth in a series of volumes that present diagrammatically the spectra of atoms and monatomic ions. All observed transitions and all known levels of manganese are included. All wavelengths are given in angstroms in vacuum below 2000 A, in air above 2000 A. Energies of levels are specified in wavenumbers (cm -1 ), kcm -1 (1 X 10 3 cm -1 ), or Mcm -1 (1 X 10 6 cm -1 ). For energies, all experimentally significant figures are included; for wavelengths, we usually include two decimal places (three for the shortest wavelengths). Descriptions of levels are based in most cases upon the largest percentage contributions of elementary coupling arrangements to the levels. In a few instances several different descriptions of the same levels are presented. (Auth.)

  20. Citizen awareness level of the peaceful uses of atomic energy

    International Nuclear Information System (INIS)

    Elfawairs, Kh.; Elammari, M.

    2015-01-01

    This paper aims to know the level of public awareness of different types of people, about the peaceful application of nuclear energy. A questionnaire about this subject was distributed randomly in different cities in Libya; the questionnaire was targeting males and females with different educational levels. From data obtained and which was analyzed statistically comparing the educational level with the level of awareness. It was found that the highest contribution was for those holding university degrees 43%. Data analysis showed that 50.5% of the total number do not know what is meant by the peaceful uses of atomic energy and this significantly related to the educational level at significance level ∝=0.01. Concerning the assessment of environmental awareness of the Libyan citizens, 83.3% said that it is weak and the relation is not signification. Concerning the best ways of making people more aware of atomic energy and its peaceful uses 63.9% said all possible means should be used and 21.3% said practical application is the best way, where 13.9% said that they don't know. About the uses of nuclear technology in different fields, the participants had different views. From this study it was concluded that a%. Warnaco programs concerning the peaceful uses of atomic energy should be intensified.(author)

  1. Energy levels and radiative rates for transitions in Ti VI

    International Nuclear Information System (INIS)

    Aggarwal, K M; Keenan, F P; Msezane, A Z

    2013-01-01

    We report on calculations of energy levels, radiative rates, oscillator strengths and line strengths for transitions among the lowest 253 levels of the (1s 2 2s 2 2p 6 ) 3s 2 3p 5 , 3s3p 6 , 3s 2 3p 4 3d, 3s3p 5 3d, 3s 2 3p 3 3d 2 , 3s 2 3p 4 4s, 3s 2 3p 4 4p and 3s 2 3p 4 4d configurations of Ti VI. The general-purpose relativistic atomic structure package and flexible atomic code are adopted for the calculations. Radiative rates, oscillator strengths and line strengths are reported for all electric dipole (E1), magnetic dipole (M1), electric quadrupole (E2) and magnetic quadrupole (M2) transitions among the 253 levels, although calculations have been performed for a much larger number of levels. Comparisons are made with existing available results and the accuracy of the data is assessed. Additionally, lifetimes for all 253 levels are listed, although comparisons with other theoretical results are limited to only 88 levels. Our energy levels are estimated to be accurate to better than 1% (within 0.03 Ryd), whereas results for other parameters are probably accurate to better than 20%. A reassessment of the energy level data on the National Institute of Standards and Technology website for Ti VI is suggested. (paper)

  2. The load-velocity profile differs more between men and women than between individuals with different strength levels.

    Science.gov (United States)

    Torrejón, Alejandro; Balsalobre-Fernández, Carlos; Haff, G Gregory; García-Ramos, Amador

    2018-03-21

    This study aimed to determine the suitability of the load-velocity relationship to prescribe the relative load (%1RM) in women, as well as to compare the load-velocity profile between sexes and participants with different strength levels. The load-velocity relationship of 14 men (1RM: 1.17 ± 0.19) and 14 women (1RM: 0.66 ± 0.13) were evaluated in the bench press exercise. The main findings revealed that: (I) the load-velocity relationship was always strong and linear (R 2 range: 0.987-0.993), (II) a steeper load-velocity profile was observed in men compared to women (Effect size [ES]: 1.09), with men showing higher velocities for light loads (ES: - 0.81 and - 0.40 for the y-intercept and 30%1RM, respectively), but women reporting higher velocities for the heavy loads (ES: 1.14 and 1.50 at 90%1RM and 100%1RM, respectively); and (III) while the slope of the load-velocity profile was moderately steeper for weak men compared to their strong counterpart (ES: 1.02), small differences were observed between strong and weak women (ES: - 0.39). While these results support the use of the individual load-velocity relationship to prescribe the %1RM in the bench press exercise for women, they also highlight the large disparities in their load-velocity profile compared to men.

  3. Unutilized energy utilizing systems. ; Power and levelling measures and unutilized energies. Miriyo energy katsuyo system. ; Denryoku fuka heijunka taisaku to miriyo energy

    Energy Technology Data Exchange (ETDEWEB)

    Kuromoto, E. (The Tokyo Electric Power Co. Inc., Tokyo (Japan))

    1993-02-12

    This paper explains quantitatively performance of heat storage tanks contributing largely to levelling power loads, and promoting and spreading more effective use of unutilized energies. A model case was used to compare differences in effectiveness of unutilized energy utilization with and without use of heat storage tanks. The heat demand used was a value in a day with a peak room cooling demand, and a heat supply system using water heat source heat pumps that utilize sewage treated water was used to manufacture cold water. As a result, the effective utilization rate of unutilized energy was increased to about 1.3 times when heat storage tanks were used. Effectiveness of a heat storage tank comes from its capability that excess amount of cold water manufactured during nighttime when heat demand falls by utilizing sewage treated water is stored in the heat storage tank, and the stored cold water can be supplied being mixed with cold water manufactured during daytime when heat demand rises sharply in daytime. Because sewage treated water has its annual temperature difference stabilized at about 10[degree]C, a heat pump utilizing the sewage treated water can reduce power required to produce heat of 1 Gcal by about 40% during room heating and about 15% during room cooling over the heating tower type heat pump. 8 figs., 1 tab.

  4. Ground level enhancement (GLE) energy spectrum parameters model

    Science.gov (United States)

    Qin, G.; Wu, S.

    2017-12-01

    We study the ground level enhancement (GLE) events in solar cycle 23 with the four energy spectra parameters, the normalization parameter C, low-energy power-law slope γ 1, high-energy power-law slope γ 2, and break energy E0, obtained by Mewaldt et al. 2012 who fit the observations to the double power-law equation. we divide the GLEs into two groups, one with strong acceleration by interplanetary (IP) shocks and another one without strong acceleration according to the condition of solar eruptions. We next fit the four parameters with solar event conditions to get models of the parameters for the two groups of GLEs separately. So that we would establish a model of energy spectrum for GLEs for the future space weather prediction.

  5. Energy level alignment at interfaces in organic photovoltaic devices

    International Nuclear Information System (INIS)

    Opitz, Andreas; Frisch, Johannes; Schlesinger, Raphael; Wilke, Andreas; Koch, Norbert

    2013-01-01

    Highlights: ► Energy level alignment is crucial for organic solar cell efficiency. ► Photoelectron spectroscopy can reliably determine energy levels of organic material interfaces. ► Care must be taken to avoid even subtle sample damage. -- Abstract: The alignment of energy levels at interfaces in organic photovoltaic devices is crucial for their energy conversion efficiency. Photoelectron spectroscopy (PES) is a well-established and widely used technique for determining the electronic structure of materials; at the same time PES measurements of conjugated organic materials often pose significant challenges, such as obtaining sufficiently defined sample structures and radiation-induced damage of the organic layers. Here we report how these challenges can be tackled to unravel the energy levels at interfaces in organic photovoltaic devices, i.e., electrode/organic and organic/organic interfaces. The electronic structure across entire photovoltaic multilayer devices can thus be reconciled. Finally, general considerations for correlating the electronic structure and the photovoltaic performance of devices will be discussed

  6. URBAN FEATURES AND ENERGY CONSUMPTION AT LOCAL LEVEL

    Directory of Open Access Journals (Sweden)

    Ali Soltani

    2012-12-01

    Full Text Available There has been a growing interest in discovering the human effects on the environment and energy consumption in recent decades. It is estimated that the share of energy consumed in transportation and housing systems are around 20 and 30 percent of total energy consumption respectively. Furthermore, the residential greenhouse emissions depend on urban form and structure. This paper explores the effects of urban features on residential energy consumption at neighborhood level using data collected through household questionnaire (n=140. Two residential districts in metropolitan Shiraz, south of Iran, were selected as case study areas. Different features of two areas were compared including building density, typology, housing location, parcel size, floor area and construction materials. Ordinary linear regression was used to discover the impact of explanatory variables on energy consumption. It was found that some physical variables such as parcel size, setback and number of floors played significant roles in explaining the variances exist in energy use level. The results can be used by governmental agencies to modify land use policies and subdivision rules in hope of saving energy and achieving a sustainable community.

  7. The influence of distributed generation penetration levels on energy markets

    International Nuclear Information System (INIS)

    Vahl, Fabrício Peter; Rüther, Ricardo; Casarotto Filho, Nelson

    2013-01-01

    Planning of national energy policies brings new dilemmas with the introduction of distributed generators (DG). Economic theory suggests that a perfectly competitive market would lead to efficient pricing. In the absence of competition, regulators play a fundamental role in attracting reasonably priced finance in order to maintain, refurbish and increase the infrastructure and provide services at a reasonable cost. Energy market price equilibrium is mainly dependent on suppliers, generators, energy sources and demand, represented by conventional utility grid users. Its behavior is similar to that of other commodities. As generation becomes less centralized with the increasing economic viability of renewable energy sources, new suppliers are being connected to the grid. Such evolution means the transition from a monopolistic market to a broader and more open environment, with an increasing number of competitors. We make use of variational inequalities to model a hypothetical DG market in different scenarios, from monopoly, to oligopoly, to open market. Such an approach enables different equilibrium outcomes due to different DG penetration levels. Based on these findings, we argue that energy policies for such markets must be developed according to each specific stage of the grid's lifecycle. We show how energy policies and market regulations may affect such a transition, which may be catastrophic if not managed properly, and which is dependent on the energy mix. -- Highlights: •DG affects energy markets depending on technologies, penetration and infrastructure. •Energy prices vary when the market moves from centralized to several suppliers. •Variational inequalities are presented to simulate a market under such transitions. •The increase of DG penetration level may present different energy prices variation. •If technical and political issues of smart grids are not improved, markets may crash

  8. Energy management of a university campus utilizing short-term load forecasting with an artificial neural network

    Science.gov (United States)

    Palchak, David

    Electrical load forecasting is a tool that has been utilized by distribution designers and operators as a means for resource planning and generation dispatch. The techniques employed in these predictions are proving useful in the growing market of consumer, or end-user, participation in electrical energy consumption. These predictions are based on exogenous variables, such as weather, and time variables, such as day of week and time of day as well as prior energy consumption patterns. The participation of the end-user is a cornerstone of the Smart Grid initiative presented in the Energy Independence and Security Act of 2007, and is being made possible by the emergence of enabling technologies such as advanced metering infrastructure. The optimal application of the data provided by an advanced metering infrastructure is the primary motivation for the work done in this thesis. The methodology for using this data in an energy management scheme that utilizes a short-term load forecast is presented. The objective of this research is to quantify opportunities for a range of energy management and operation cost savings of a university campus through the use of a forecasted daily electrical load profile. The proposed algorithm for short-term load forecasting is optimized for Colorado State University's main campus, and utilizes an artificial neural network that accepts weather and time variables as inputs. The performance of the predicted daily electrical load is evaluated using a number of error measurements that seek to quantify the best application of the forecast. The energy management presented utilizes historical electrical load data from the local service provider to optimize the time of day that electrical loads are being managed. Finally, the utilization of forecasts in the presented energy management scenario is evaluated based on cost and energy savings.

  9. Global Anthropogenic Phosphorus Loads to Fresh Water, Grey Water Footprint and Water Pollution Levels: A High-Resolution Global Study

    Science.gov (United States)

    Mekonnen, M. M.; Hoekstra, A. Y. Y.

    2014-12-01

    We estimated anthropogenic phosphorus (P) loads to freshwater, globally at a spatial resolution level of 5 by 5 arc minute. The global anthropogenic P load to freshwater systems from both diffuse and point sources in the period 2002-2010 was 1.5 million tonnes per year. China contributed about 30% to this global anthropogenic P load. India was the second largest contributor (8%), followed by the USA (7%), Spain and Brazil each contributing 6% to the total. The domestic sector contributed the largest share (54%) to this total followed by agriculture (38%) and industry (8%). Among the crops, production of cereals had the largest contribution to the P loads (32%), followed by fruits, vegetables, and oil crops, each contributing about 15% to the total. We also calculated the resultant grey water footprints, and relate the grey water footprints per river basin to runoff to calculate the P-related water pollution level (WPL) per catchment.

  10. Cost-optimal levels for energy performance requirements

    DEFF Research Database (Denmark)

    Thomsen, Kirsten Engelund; Aggerholm, Søren; Kluttig-Erhorn, Heike

    2011-01-01

    The CA conducted a study on experiences and challenges for setting cost optimal levels for energy performance requirements. The results were used as input by the EU Commission in their work of establishing the Regulation on a comparative methodology framework for calculating cost optimal levels...... of minimum energy performance requirements. In addition to the summary report released in August 2011, the full detailed report on this study is now also made available, just as the EC is about to publish its proposed Regulation for MS to apply in their process to update national building requirements....

  11. The Low Energy Level Structure of {sup 191}lr

    Energy Technology Data Exchange (ETDEWEB)

    Malmskog, S G; Berg, V [AB Atomenergi, Nykoeping (Sweden); [Inst. of Physics, U niv. of Stockholm (Sweden); Baecklin, A; Hedin, G [Inst. of Physics, Univ. of Upp sala (Sweden)

    1970-02-15

    The decay of {sup 191}Pt to {sup 191}Ir has been investigated using Ge(Li)-detectors and a double focusing beta spectrometer. 35 transitions were observed and most of them were placed in a level scheme. Special attention was given to the low energy level band structure. Several multipolarity mixing ratios were determined from L-subshell ratio measurements. Using the delayed coincidence technique the half-life of the 179.05 keV level was measured to 40 {+-} 12 psec. The low level decay properties are discussed in terms of the Nilsson model with the inclusion of Coriolis coupling.

  12. Experimental determination of the energy efficiency of an air-cooled chiller under part load conditions

    International Nuclear Information System (INIS)

    Yu, F.W.; Chan, K.T.

    2005-01-01

    In cities located in a subtropical climate, air-cooled chillers are commonly used to provide cooling to the indoor environment. This accounts for the increasing electricity demand of buildings over the decades. This paper investigates how the condensing temperature serves to accurately determine the energy efficiency, or coefficient of performance (COP), of air-cooled chillers under part load conditions. An experiment on an air-cooled reciprocating chiller showed that for any given operating condition, the COP of the chiller varies, depending on how the condensing temperature is controlled. A sensitivity analysis is implemented to investigate to what extent COP is responding to changes in operating variables and confirms that the condensing temperature is an adequate variable to gauge COP under various operating conditions. The specifications of the upper limit for the condensing temperature in order to improve the energy efficiency of air-cooled chillers are discussed. The results of this work will give designers and researchers a good idea about how to model chiller energy performance curves in the thermal and energy computation exercises

  13. On thermoeconomics of energy systems at variable load conditions: Integrated optimization of plant design and operation

    International Nuclear Information System (INIS)

    Piacentino, A.; Cardona, F.

    2007-01-01

    Thermoeconomics has been assuming a growing role among the disciplines oriented to the analysis of energy systems, its different methodologies allowing solution of problems in the fields of cost accounting, plant design optimisation and diagnostic of malfunctions. However, the thermoeconomic methodologies as such are particularly appropriate to analyse large industrial systems at steady or quasi-steady operation, but they can be hardly applied to small to medium scale units operating in unsteady conditions to cover a variable energy demand. In this paper, the fundamentals of thermoeconomics for systems operated at variable load are discussed, examining the cost formation process and, separately, the cost fractions related to capital depreciation (which require additional distinctions with respect to plants in steady operation) and to exergy consumption. The relevant effects of the efficiency penalty due to off design operation on the exergetic cost of internal flows are also examined. An original algorithm is proposed for the integrated optimization of plant design and operation based on an analytical solution by the Lagrange multipliers method and on a multi-objective decision function, expressed either in terms of net cash flow or primary energy saving. The method is suitable for application in complex energy systems, such as 'facilities of components of a same product' connected to external networks for power or heat distribution. For demonstrative purposes, the proposed thermoeconomically aided optimization is performed for a grid connected trigeneration system to be installed in a large hotel

  14. Box-triangular multiobjective linear programs for resource allocation with application to load management and energy market problems

    International Nuclear Information System (INIS)

    Ekel, P.Y.; Galperin, E.A.

    2003-01-01

    Models for multicriteria resource allocation are constructed with the specific box-triangular structure of a feasible region. The method of balance set equations is extended for the satisfaction level representation of the cost function space including the case of linearly dependent cost functions. On this basis, different goal criteria on the balance set are investigated for linear cases. Procedures for determining the balance set and finding goal-optimal Pareto solutions are illustrated on examples. The results of the paper are of universal character and can find wide applications in allocating diverse types of resources on the multiobjective basis in planning and control of complex systems including load management and energy market problems. (Author)

  15. The Spatial Release of Cognitive Load in Cocktail Party Is Determined by the Relative Levels of the Talkers.

    Science.gov (United States)

    Andéol, Guillaume; Suied, Clara; Scannella, Sébastien; Dehais, Frédéric

    2017-06-01

    In a multi-talker situation, spatial separation between talkers reduces cognitive processing load: this is the "spatial release of cognitive load". The present study investigated the role played by the relative levels of the talkers on this spatial release of cognitive load. During the experiment, participants had to report the speech emitted by a target talker in the presence of a concurrent masker talker. The spatial separation (0° and 120° angular distance in azimuth) and the relative levels of the talkers (adverse, intermediate, and favorable target-to-masker ratio) were manipulated. The cognitive load was assessed with a prefrontal functional near-infrared spectroscopy. Data from 14 young normal-hearing listeners revealed that the target-to-masker ratio had a direct impact on the spatial release of cognitive load. Spatial separation significantly reduced the prefrontal activity only for the intermediate target-to-masker ratio and had no effect on prefrontal activity for the favorable and the adverse target-to-masker ratios. Therefore, the relative levels of the talkers might be a key point to determine the spatial release of cognitive load and more specifically the prefrontal activity induced by spatial cues in multi-talker situations.

  16. Review of Evaluation, Measurement and Verification Approaches Used to Estimate the Load Impacts and Effectiveness of Energy Efficiency Programs

    Energy Technology Data Exchange (ETDEWEB)

    Messenger, Mike; Bharvirkar, Ranjit; Golemboski, Bill; Goldman, Charles A.; Schiller, Steven R.

    2010-04-14

    Efficiency (2007) presented commonly used definitions for EM&V in the context of energy efficiency programs: (1) Evaluation (E) - The performance of studies and activities aimed at determining the effects and effectiveness of EE programs; (2) Measurement and Verification (M&V) - Data collection, monitoring, and analysis associated with the calculation of gross energy and demand savings from individual measures, sites or projects. M&V can be a subset of program evaluation; and (3) Evaluation, Measurement, and Verification (EM&V) - This term is frequently seen in evaluation literature. EM&V is a catchall acronym for determining both the effectiveness of program designs and estimates of load impacts at the portfolio, program and project level. This report is a scoping study that assesses current practices and methods in the evaluation, measurement and verification (EM&V) of ratepayer-funded energy efficiency programs, with a focus on methods and practices currently used for determining whether projected (ex-ante) energy and demand savings have been achieved (ex-post). M&V practices for privately-funded energy efficiency projects (e.g., ESCO projects) or programs where the primary focus is greenhouse gas reductions were not part of the scope of this study. We identify and discuss key purposes and uses of current evaluations of end-use energy efficiency programs, methods used to evaluate these programs, processes used to determine those methods; and key issues that need to be addressed now and in the future, based on discussions with regulatory agencies, policymakers, program administrators, and evaluation practitioners in 14 states and national experts in the evaluation field. We also explore how EM&V may evolve in a future in which efficiency funding increases significantly, innovative mechanisms for rewarding program performance are adopted, the role of efficiency in greenhouse gas mitigation is more closely linked, and programs are increasingly funded from multiple sources

  17. Technical and economic assessment of fluidized-bed-augmented compressed-air energy-storage system: system load following capability

    Energy Technology Data Exchange (ETDEWEB)

    Lessard, R.D.; Blecher, W.A.; Merrick, D.

    1981-09-01

    The load-following capability of fluidized bed combustion-augmented compressed air energy storage systems was evaluated. The results are presented in two parts. The first part is an Executive Summary which provides a concise overview of all major elements of the study including the conclusions, and, second, a detailed technical report describing the part-load and load following capability of both the pressurized fluid bed combustor and the entire pressurized fluid bed combustor/compressed air energy storage system. The specific tasks in this investigation were to: define the steady-state, part-load operation of the CAES open-bed PFBC; estimate the steady-state, part-load performance of the PFBC/CAES system and evaluate any possible operational constraints; simulate the performance of the PFBC/CAES system during transient operation and assess the load following capability of the system; and establish a start-up procedure for the open-bed PFBC and evaluate the impact of this procedure. The conclusions are encouraging and indicate that the open-bed PFBC/CAES power plant should provide good part-load and transient performance, and should have no major equipment-related constraints, specifically, no major problems associated with the performance or design of either the open-end PFBC or the PFBC/CAES power plant in steady-state, part-load operation are envisioned. The open-bed PFBC/CAES power plant would have a load following capability which would be responsive to electric utility requirements for a peak-load power plant. The open-bed PFBC could be brought to full operating conditions within 15 min after routine shutdown, by employing a hot-start mode of operation. The PFBC/CAES system would be capable of rapid changes in output power (12% of design load per minute) over a wide output power range (25% to 100% of design output). (LCL)

  18. Assessment of high temperature nuclear energy storage systems for the production of intermediate and peak-load electric power

    International Nuclear Information System (INIS)

    Fox, E.C.; Fuller, L.C.; Silverman, M.D.

    1977-01-01

    Increased cost of energy, depletion of domestic supplies of oil and natural gas, and dependence on foreign suppliers, have led to an investigation of energy storage as a means to displace the use of oil and gas presently being used to generate intermediate and peak-load electricity. Dedicated nuclear thermal energy storage is investigated as a possible alternative. An evaluation of thermal storage systems is made for several reactor concepts and economic comparisons are presented with conventional storage and peak power producing systems. It is concluded that dedicated nuclear storage has a small but possible useful role in providing intermediate and peak-load electric power

  19. Energy level alignment at Co/AlOx/pentacene interfaces

    NARCIS (Netherlands)

    Popinciuc, M.; Jonkman, H. T.; van Wees, B. J.

    2007-01-01

    X-ray and ultraviolet photoemission spectroscopy (XPS and UPS) experiments were performed in order to study the energy level alignment and electronic structure at Co/AlOx/pentacene interfaces as a function of the aluminum oxide (AlOx) tunnel barrier thickness and the oxidation state of Co. XPS was

  20. Investigation of the energy levels of 38AR

    International Nuclear Information System (INIS)

    Waanders, F.B.

    1975-07-01

    In this project information on the energy levels of 38 Ar was obtained by means of the (p,γ) reaction. The 1,1 MeV Cockroft-Walton accelerator of the Potchefstroom University for CHE was used to produce the proton beam while a 80 cm 3 Ge(Li) detector was used to detect the gamma-rays. Precise gamma-branchings were determined for 50 bound levels, of which four have not previously been determined. These branchings were obtained from the 28 resonances studied in the 37 Cl(p,γ) 38 Ar reaction. The resonance with a proton energy of (592 plus minus 3) keV was not detected previously. The resonance energies, Q-value and energies of the bound levels used in this project were taken from the study done by Alderliesten. The mean lifetimes of a few bound levels of 38 Ar were measured by means of the doppler shift attenuation method. The results concerning the bound states and mean lifetimes are in good agreement with previous experiments. Limitations on the spin and parities of 19 (p,γ) resonances have been set by means of Weisskopf estimates. Only those cases for which the spin could be limited to two values are discussed in the text. A summary of experimental data obtained on 38 Ar is compared with the results from shellmodel calculations done by various workers. A short discussion on the analogue states in 38 Ar is also given [af

  1. Coulomb displacement energies between analog levels for 44 < = A < = 239

    International Nuclear Information System (INIS)

    Antony, M.S.; Britz, J.; Pape, A.

    1985-08-01

    Experimental Coulomb displacement energie ΔEsub(C) between isobaric analog levels are tabulated for 44 <- A <- 239, extending recent work in which similar data were presented for 3 <- A <- 45. An overall parametrization in anti-Z/A sup(1/3) and uniform radius parameters rsub(o) are given

  2. Degeneracy of energy levels of pseudo-Gaussian oscillators

    International Nuclear Information System (INIS)

    Iacob, Theodor-Felix; Iacob, Felix; Lute, Marina

    2015-01-01

    We study the main features of the isotropic radial pseudo-Gaussian oscillators spectral properties. This study is made upon the energy levels degeneracy with respect to orbital angular momentum quantum number. In a previous work [6] we have shown that the pseudo-Gaussian oscillators belong to the class of quasi-exactly solvable models and an exact solution has been found

  3. Net energy levels on the lipid profile of pork

    Directory of Open Access Journals (Sweden)

    Stephan Alexander da Silva Alencar

    2017-09-01

    Full Text Available ABSTRACT: This study was conducted to evaluate the effects of net energy levels on the lipid profile of adipose tissue and muscle of swines. A total of 90 animals, with initial weight of 71.94±4.43kg, were used, and distributed in a randomized block design in five net energy levels (2,300, 2,425, 2,550, 2,675, and 2,800Kcal kg-1 feed, with nine replicates and two animals per experimental unit. Lipid profiles of adipose tissue and muscle were analyzed using gas chromatography. Increasing the levels of net energy using soybean oil, improved the lipid profile of adipose tissue and muscle, increased linearly (P<0.05 the concentrations of polyunsaturated fatty acids, especially linoleic and α-linolenic acid, reduced linearly (P<0.05 the monounsaturated and saturated fatty acids and omega 6: omega 3. In adipose tissue was observed linear reduction (P<0.05 of atherogenic and thrombogenic indexes. In conclusion, increasing the level of net energy of the diet using soybean oil improved the lipid profile of adipose tissue and muscle.

  4. Energy level alignment symmetry at Co/pentacene/Co interfaces

    NARCIS (Netherlands)

    Popinciuc, M.; Jonkman, H. T.; van Wees, B. J.

    2006-01-01

    We have employed x-ray and ultraviolet photoemission spectroscopies (XPS and UPS) to study the energy level alignment and electronic structure at the Co/pentacene/Co interfaces. In the case of pentacene deposition on Co we found an interfacial dipole of about 1.05 eV and a hole injection barrier of

  5. Dietary energy level for optimum productivity and carcass ...

    African Journals Online (AJOL)

    A study was conducted to determine dietary energy levels for optimum productivity and carcass characteristics of indigenous Venda chickens raised in closed confinement. Four dietary treatments were considered in the first phase (1 to 7 weeks) on two hundred day-old unsexed indigenous Venda chicks indicated as EVS1, ...

  6. Evaluation of renal oxygenation level changes after water loading using susceptibility-weighted imaging and T2{sup *} mapping

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Jiule; Xing, Wei; Chen, Jie; Pan, Liang; Sun, Jun; Xing, Shi Jun [Dept. of Radiology, Third Affiliated Hospital of Suzhou University, Changzhou (China); Wu, Dong Mei [Shanghai Key Laboratory of Magnetic Resonance Imaging, East China Normal University, Shanghai (China); Dai, Yong Ming [Philips Healthcare, Shanghai (China)

    2015-08-15

    To assess the feasibility of susceptibility-weighted imaging (SWI) while monitoring changes in renal oxygenation level after water loading. Thirty-two volunteers (age, 28.0 ± 2.2 years) were enrolled in this study. SWI and multi-echo gradient echo sequence-based T2{sup *} mapping were used to cover the kidney before and after water loading. Cortical and medullary parameters were measured using small regions of interest, and their relative changes due to water loading were calculated based on baseline and post-water loading data. An intraclass correlation coefficient analysis was used to assess inter-observer reliability of each parameter. A receiver operating characteristic curve analysis was conducted to compare the performance of the two methods for detecting renal oxygenation changes due to water loading. Both medullary phase and medullary T2{sup *} values increased after water loading (p < 0.001), although poor correlations were found between the phase changes and the T2{sup *} changes (p > 0.05). Interobserver reliability was excellent for the T2{sup *} values, good for SWI cortical phase values, and moderate for the SWI medullary phase values. The area under receiver operating characteristic curve of the SWI medullary phase values was 0.85 and was not different from the medullary T2{sup *} value (0.84). Susceptibility-weighted imaging enabled monitoring changes in the oxygenation level in the medulla after water loading, and may allow comparable feasibility to detect renal oxygenation level changes due to water loading compared with that of T2{sup *} mapping.

  7. Multi-Temporal Decomposed Wind and Load Power Models for Electric Energy Systems

    Science.gov (United States)

    Abdel-Karim, Noha

    electricity market rules capable of providing the right incentives to manage uncertainties and of differentiating various technologies according to the rate at which they can respond to ever changing conditions. Given the overall need for modeling uncertainties in electric energy systems, we consider in this thesis the problem of multi-temporal modeling of wind and demand power, in particular. Historic data is used to derive prediction models for several future time horizons. Short-term prediction models derived can be used for look-ahead economic dispatch and unit commitment, while the long-term annual predictive models can be used for investment planning. As expected, the accuracy of such predictive models depends on the time horizons over which the predictions are made, as well as on the nature of uncertain signals. It is shown that predictive models obtained using the same general modeling approaches result in different accuracy for wind than for demand power. In what follows, we introduce several models which have qualitatively different patterns, ranging from hourly to annual. We first transform historic time-stamped data into the Fourier Transform (Fr) representation. The frequency domain data representation is used to decompose the wind and load power signals and to derive predictive models relevant for short-term and long-term predictions using extracted spectral techniques. The short-term results are interpreted next as a Linear Prediction Coding Model (LPC) and its accuracy is analyzed. Next, a new Markov-Based Sensitivity Model (MBSM) for short term prediction has been proposed and the dispatched costs of uncertainties for different predictive models with comparisons have been developed. Moreover, the Discrete Markov Process (DMP) representation is applied to help assess probabilities of most likely short-, medium- and long-term states and the related multi-temporal risks. In addition, this thesis discusses operational impacts of wind power integration in

  8. A load predictive energy management system for supercapacitor-battery hybrid energy storage system in solar application using the Support Vector Machine

    International Nuclear Information System (INIS)

    Chia, Yen Yee; Lee, Lam Hong; Shafiabady, Niusha; Isa, Dino

    2015-01-01

    Highlights: • A novel energy management system (EMS) for supercapacitor-battery hybrid energy storage system is implemented. • It is a load predictive EMS which is implemented using Support Vector Machine (SVM). • An optimum SVM load prediction model is obtained, which yields 100% accuracy in 0.004866 s of training time. • The implemented load predictive EMS is compared with the conventional sequential programming control. • This methodology reduces the number of power electronics used and prolong battery lifespan. - Abstract: This paper presents the use of a Support Vector Machine load predictive energy management system to control the energy flow between a solar energy source, a supercapacitor-battery hybrid energy storage combination and the load. The supercapacitor-battery hybrid energy storage system is deployed in a solar energy system to improve the reliability of delivered power. The combination of batteries and supercapacitors makes use of complementary characteristic that allow the overlapping of a battery’s high energy density with a supercapacitors’ high power density. This hybrid system produces a straightforward benefit over either individual system, by taking advantage of each characteristic. When the supercapacitor caters for the instantaneous peak power which prolongs the battery lifespan, it also minimizes the system cost and ensures a greener system by reducing the number of batteries. The resulting performance is highly dependent on the energy controls implemented in the system to exploit the strengths of the energy storage devices and minimize its weaknesses. It is crucial to use energy from the supercapacitor and therefore minimize jeopardizing the power system reliability especially when there is a sudden peak power demand. This study has been divided into two stages. The first stage is to obtain the optimum SVM load prediction model, and the second stage carries out the performance comparison of the proposed SVM-load predictive

  9. Mode shape combination in a two-dimensional vibration energy harvester through mass loading structural modification

    Energy Technology Data Exchange (ETDEWEB)

    Sharpes, Nathan; Kumar, Prashant [Center for Energy Harvesting Materials and Systems (CEHMS), Virginia Tech, Blacksburg, Virginia 24061 (United States); Abdelkefi, Abdessattar; Abdelmoula, Hichem [Department of Mechanical and Aerospace Engineering, New Mexico State University, Las Cruces, New Mexico 88003 (United States); Adler, Jan [Center for Energy Harvesting Materials and Systems (CEHMS), Virginia Tech, Blacksburg, Virginia 24061 (United States); Institute of Dynamics and Vibration Research (IDS), Leibniz Universität, Hannover 30167 (Germany); Priya, Shashank [Center for Energy Harvesting Materials and Systems (CEHMS), Virginia Tech, Blacksburg, Virginia 24061 (United States); Bio-Inspired Materials and Devices Laboratory (BMDL), Virginia Tech, Blacksburg, Virginia 24061 (United States)

    2016-07-18

    Mode shapes in the design of mechanical energy harvesters, as a means of performance increase, have been largely overlooked. Currently, the vast majority of energy harvester designs employ some variation of a single-degree-of-freedom cantilever, and the mode shapes of such beams are well known. This is especially true for the first bending mode, which is almost exclusively the chosen vibration mode for energy harvesting. Two-dimensional beam shapes (those which curve, meander, spiral, etc., in a plane) have recently gained research interest, as they offer freedom to modify the vibration characteristics of the harvester beam for achieving higher power density. In this study, the second bending mode shape of the “Elephant” two-dimensional beam shape is examined, and its interaction with the first bending mode is evaluated. A combinatory mode shape created by using mass loading structural modification to lower the second bending modal frequency was found to interact with the first bending mode. This is possible since the first two bending modes do not share common areas of displacement. The combined mode shape is shown to produce the most power of any of the considered mode shapes.

  10. Spectrum and energy levels of kryptonlike ion Nb VI

    International Nuclear Information System (INIS)

    Reader, J.; Ekberg, J.O.

    1993-01-01

    The spectrum of five-times ionized niobium, Nb, VI, was observed from 238 to 2700 angstrom with sliding spark discharges on 10.7-m normal- and grazing-incidence spectrographs. Experimental energies were determined for all levels of the 4s 2 4p 6 , 4s 2 4p 6 , 4s 2 4p 5 4d, 4f, 5s, 5p, 5g, 6s, and 4s4p 6 4d configurations as well as some levels of 4p 5 6g. A total of 291 lines were classified as transitions between 88 observed levels. A previous analysis of this spectrum was found to be totally erroneous. Large hyperfine splittings were found for several levels of the 4p 5 5s and 5p configurations. The observed configurations were theoretically interpreted by means of Hartree-Fock calculations and least squares fits of the energy parameters to the observed levels. A revised value of the ionization energy was obtained from the 4p 5 5g and 6g configurations

  11. Investigation of load leveling in Hokuriku Electric Power Co., Inc.; Hokuriku denryoku no fuka heijunka eno torikumi

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-08-01

    Hokuriku Electric Power Co., Inc. aims at an around 2% improvement of the load factor up to 2005, by which the quick and proper service and the proposal of load leveling menu are planned. This paper describes an outline of the investigation of load leveling. Various programs have been proposed so that the customers can further shift the load by their consideration. Proposed systems include the time-of-day electricity rate system, the load regulation contract system for industries, the seasonal time-of-day rate system, the electric power system for snowmelt in which the load is dumped at the peak, and the secondary electric power system for snowmelt. Accompanying with the revision of electric utility law, the enlargement of its available time, the price reduction, and the discount rate system for the ice regenerative air conditioners have been provided. For the business activities, a demonstration model house was exhibited to indicate a proper house with local characteristics in Hokuriku district. Furthermore, the spreading activities of regenerative systems and the consulting activities have been positively promoted. 4 figs., 1 tab.

  12. Load management strategy for Particle-In-Cell simulations in high energy particle acceleration

    Energy Technology Data Exchange (ETDEWEB)

    Beck, A., E-mail: beck@llr.in2p3.fr [Laboratoire Leprince-Ringuet, École polytechnique, CNRS-IN2P3, Palaiseau 91128 (France); Frederiksen, J.T. [Niels Bohr Institute, University of Copenhagen, Blegdamsvej 17, 2100 København Ø (Denmark); Dérouillat, J. [CEA, Maison de La Simulation, 91400 Saclay (France)

    2016-09-01

    In the wake of the intense effort made for the experimental CILEX project, numerical simulation campaigns have been carried out in order to finalize the design of the facility and to identify optimal laser and plasma parameters. These simulations bring, of course, important insight into the fundamental physics at play. As a by-product, they also characterize the quality of our theoretical and numerical models. In this paper, we compare the results given by different codes and point out algorithmic limitations both in terms of physical accuracy and computational performances. These limitations are illustrated in the context of electron laser wakefield acceleration (LWFA). The main limitation we identify in state-of-the-art Particle-In-Cell (PIC) codes is computational load imbalance. We propose an innovative algorithm to deal with this specific issue as well as milestones towards a modern, accurate high-performance PIC code for high energy particle acceleration.

  13. ENERGY SYSTEM DEVELOPMENT AND LOAD MANAGEMENT THROUGH THE REHABILITATION AND RETURN TO PLAY PROCESS.

    Science.gov (United States)

    Morrison, Scot; Ward, Patrick; duManoir, Gregory R

    2017-08-01

    Return-to-play from injury is a complex process involving many factors including the balancing of tissue healing rates with the development of biomotor abilities. This process requires interprofessional cooperation to ensure success. An often-overlooked aspect of return-to-play is the development and maintenance of sports specific conditioning while monitoring training load to ensure that the athlete's training stimulus over the rehabilitation period is appropriate to facilitate a successful return to play. The purpose of this clinical commentary is to address the role of energy systems training as part of the return-to-play process. Additionally the aim is to provide practitioners with an overview of practical sports conditioning training methods and monitoring strategies to allow them to direct and quantify the return-to-play process. 5.

  14. Energy balance of lactating primiparous sows as affected by feeding level and dietary energy source

    NARCIS (Netherlands)

    Brand, van den H.; Heetkamp, M.J.W.; Soede, N.M.; Schrama, J.W.; Kemp, B.

    2000-01-01

    The effects of feeding level and major dietary energy source used during lactation on sow milk composition, piglet body composition, and energy balance of sows were determined. During a 21-d lactation, 48 primiparous sows were fed either a Fat-rich (134.9 g/kg fat; 196.8 g/kg carbohydrate) or a

  15. Miscellaneous and Electronic Loads Energy Efficiency Opportunities for Commercial Buildings: A Collaborative Study by the United States and India

    Energy Technology Data Exchange (ETDEWEB)

    Ghatikar, Girish [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Cheung, Iris [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Lanzisera, Steven [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Wardell, Bob [Infosys Technologies Limited; Deshpande, Manoj [Infosys Technologies Limited; Ugarkar, Jayraj [Infosys Technologies Limited

    2013-04-01

    This report documents the technical evaluation of a collaborative research, development, and demonstration (RD&D) project that aims to address energy efficiency of Miscellaneous and Electronic Loads (MELs) (referred to as plug loads interchangeably in this report) using load monitoring and control devices. The goal s of this project are to identify and provide energy efficiency and building technologies to exemplary information technology (IT) office buildings, and to assist in transforming markets via technical assistance and engagement of Indian and U.S. stakeholders. This report describes the results of technology evaluation and United States – India collaboration between the Lawrence Berkeley National Laboratory (LBNL), Infosys Technologies Limited (India), and Smartenit, Inc. (U.S.) to address plug - load efficiency. The conclusions and recommendations focus on the larger benefits of such technologies and their impacts on both U.S. and Indian stakeholders.

  16. Framework for State-Level Renewable Energy Market Potential Studies

    Energy Technology Data Exchange (ETDEWEB)

    Kreycik, C.; Vimmerstedt, L.; Doris, E.

    2010-01-01

    State-level policymakers are relying on estimates of the market potential for renewable energy resources as they set goals and develop policies to accelerate the development of these resources. Therefore, accuracy of such estimates should be understood and possibly improved to appropriately support these decisions. This document provides a framework and next steps for state officials who require estimates of renewable energy market potential. The report gives insight into how to conduct a market potential study, including what supporting data are needed and what types of assumptions need to be made. The report distinguishes between goal-oriented studies and other types of studies, and explains the benefits of each.

  17. Efforts of load leveling in Tohoku Electric Power Co. Inc.; Tohoku denryoku no fuka heijunka eno torikumi ni tsuite

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-05-01

    This paper describes efforts of load leveling in Tohoku Electric Power Co., Inc. from the viewpoint of the rate system and business development. For the approach from the rate system, various rate menus for the peak shift have been arranged for domestic and large industry customers. To create the midnight demand, spread and expansion of electric hot water service are promoted. Consequently, the contract of midnight power has reached 914,000 kW at the end of 1995, which was 774,000 kW in 1985. To spread the ice regenerative air conditioning systems, the grant of incentive to the manufacturers and special discount of electricity rate have been conducted. These systems have been introduced in the eight places of Tohoku Electric Power`s business. The spread incident system has been created to introduce the automatic vending machines for beverages with the power peak cut function. Unused energy, such as exhaust heat from the non-treated sewage water and substations has been utilized as a heat supply project for city redevelopment. Multi-functional heat pump with regenerative function has been developed. This system aims at the peak shift by combining multi-functional heat pump and electric hot water service. 2 figs., 2 tabs.

  18. Energy levels, lifetimes and radiative data of W LV

    Science.gov (United States)

    Ding, Xiao-bin; Sun, Rui; Koike, Fumihiro; Murakami, Izumi; Kato, Daiji; Sakaue, Hiroyuki A.; Nakamura, Nobuyuki; Dong, Chen-zhong

    2018-01-01

    Calculations of energy levels, radiative data and lifetimes are reported for tungsten Ca-like ion (W LV) by using multi-configuration Dirac-Fock (MCDF) method. The GRASP2K package is adopted to carry out a large-scale systematic computation with a restricted active space treatment; the Breit interaction and QED effects are included in subsequent relativistic configuration interaction calculations. The energies and lifetimes of the lowest 119 levels are listed; the main leading configuration of the levels is of the ground state configuration [Ne]3s23p63d2 and the first excited configuration [Ne]3s23p53d3. The wavelengths, radiative rates and oscillator strengths for relatively strong E1, E2, M1, and M2 transitions are listed. Comparisons with earlier experimental and theoretical values are made. The average relative deviations of energy levels from the NIST results and E1 transition wavelengths from the EBIT experimental results have turned to be only 0.20% and 0.13%, respectively. The other present results are in reasonable agreement with available data. These agreements confirm the reliability and accuracy of the current results. The present datasets may help us with the investigation of the electron-electron correlation effects in complex multi-electron highly charged heavy ions and of the diagnosis of tungsten impurity plasmas in fusion science.

  19. Renewable energy the best remedy for electrical load shedding in Pakistan

    International Nuclear Information System (INIS)

    Bhutta, S.M.

    2011-01-01

    Average 33% time of daily electrical load shedding in Pakistan is most serious as it has affected all activities. Industries are crippled, commercial, official activities and daily life is being deteriorated Total loss to Export is 1.3 and oil import bill is $ 9 Billion. If appropriate actions are not taken immediately; the situation is going to get worse when people will fight for every watt of electricity. The impounding crises are not foreseen and its gravity is not yet properly realized by the decision makers. Politics and several lobbies work against construction of major projects of hydel power and baseless controversies have been created. Pakistan is blessed with abundant renewable energy i.e. 2.9 million MW solar, tidal, wind 346,000 MW and 59,000 MW potentials of hydro electricity. Analysis of the reasons for the slow and no growth of these vital renewable potentials in Pakistan indicate that there are barriers which need to be mitigated to take immediate benefits to overcome menace of load shedding. Local R and D, Design, manufacturing, installation and feasibility study capabilities are negligible. Institutional capabilities in most of the organizations can at best be ranked as average or weak. Other impediments and barriers that continue to hamper the load shedding are losses, attitude in the promotion of renewable and hydro power projects include: lack of serious attempts to mitigate the barriers, integrate the programs with profitability; inadequate evaluation of resources; non availability of reliable baseline data; and lack of coordination among the relevant agencies; weak institutional arrangements for renewable energy promotion; absence of fiscal and financing mechanisms; lack of understanding, awareness, information and outreach; uneven allocation of resources; lack of appropriate quality management, monitoring and evaluation programs; and need of attractive policy framework and legislative support, building consensus among people and provinces

  20. Meticulous plasma isolation is essential to avoid false low-level viraemia in Roche Cobas HIV-1 viral load assays.

    Science.gov (United States)

    Mortier, Virginie; Vancoillie, Leen; Dauwe, Kenny; Staelens, Delfien; Demecheleer, Els; Schauvliege, Marlies; Dinakis, Sylvie; Van Maerken, Tom; Dessilly, Géraldine; Ruelle, Jean; Verhofstede, Chris

    2017-10-24

    Pre-analytical sample processing is often overlooked as a potential cause of inaccurate assay results. Here we demonstrate how plasma, extracted from standard EDTA-containing blood collection tubes, may contain traces of blood cells consequently resulting in a false low-level HIV-1 viral load when using Roche Cobas HIV-1 assays. The presence of human DNA in Roche Cobas 4800 RNA extracts and in RNA extracts from the Abbott HIV-1 RealTime assay was assessed by quantifying the human albumin gene by means of quantitative PCR. RNA was extracted from plasma samples before and after an additional centrifugation and tested for viral load and DNA contamination. The relation between total DNA content and viral load was defined. Elevated concentrations of genomic DNA were detected in 28 out of 100 Cobas 4800 extracts and were significantly more frequent in samples processed outside of the AIDS Reference Laboratory. An association between genomic DNA presence and spurious low-level viraemia results was demonstrated. Supplementary centrifugation of plasma before RNA extraction eliminated the contamination and the false viraemia. Plasma isolated from standard EDTA-containing blood collection tubes may contain traces of HIV DNA leading to false viral load results above the clinical cutoff. Supplementary centrifugation of plasma before viral load analysis may eliminate the occurrence of this spurious low-level viraemia.

  1. Energy Level Composite Curves-a new graphical methodology for the integration of energy intensive processes

    International Nuclear Information System (INIS)

    Anantharaman, Rahul; Abbas, Own Syed; Gundersen, Truls

    2006-01-01

    Pinch Analysis, Exergy Analysis and Optimization have all been used independently or in combination for the energy integration of process plants. In order to address the issue of energy integration, taking into account composition and pressure effects, the concept of energy level as proposed by [X. Feng, X.X. Zhu, Combining pinch and exergy analysis for process modifications, Appl. Therm. Eng. 17 (1997) 249] has been modified and expanded in this work. We have developed a strategy for energy integration that uses process simulation tools to define the interaction between the various subsystems in the plant and a graphical technique to help the engineer interpret the results of the simulation with physical insights that point towards exploring possible integration schemes to increase energy efficiency. The proposed graphical representation of energy levels of processes is very similar to the Composite Curves of Pinch Analysis-the interpretation of the Energy Level Composite Curves reduces to the Pinch Analysis case when dealing with heat transfer. Other similarities and differences are detailed in this work. Energy integration of a methanol plant is taken as a case study to test the efficacy of this methodology. Potential integration schemes are identified that would have been difficult to visualize without the help of the new graphical representation

  2. Load leveling efforts of The Hokkaido Electric Power Co. Inc.; Hokkaido Denryoku no fuka heijunka eno torikumi ni tsuite

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-04-01

    The Hokkaido Electric Power Co., Inc., aiming to enhance power generation efficiency through power load levelling, strives to expand and substantiate its electricity billing menu and to popularize and encourage the use of levelling-oriented apparatuses and systems most of which are designed for utilizing midnight power. The billing menu has in it a snow-melting power which is cut off for load levelling during the peak demand time zone. For domestic use, a time zone-specified lighting system named Dream Eight is created, which is one of the billing systems dependent upon time zone. Introduced therein for industrial use is a demand/supply adjustment contract system. Furthermore, in compliance with the amended Electricity Business Law that came into force in 1995, efforts are under way for revising the period wherein power is to be supplied for melting snow, expanding the scope of application of the power supply system dependent upon time zone, and newly introducing a heat accumulation assisted peak adjustment contract system and an operation adjustment contract system. As for business efforts in relation to load levelling, the company proposes household electrical systems centering about 200V high-efficiency apparatuses, electric water warmer contributing to the enhancement of year-round load levelling, popularization and reinforcement of electric snow melting systems, and power utilizing technologies capable of meeting local demands raised for example by agriculture and fishery.

  3. Spinless Salpeter equation: Laguerre bounds on energy levels

    International Nuclear Information System (INIS)

    Lucha, W.; Schoeberl, F.F.

    1996-08-01

    The spinless Salpeter equation may be considered either as a standard approximation to the Bethe-Salpeter formalism, designed for the description of bound states within a relativistic quantum field theory, or as the most simple, to a certain extent relativistic generalization of the customary non relativistic Schroedinger formalism. Because of the presence of the rather difficult-to-handle square-root operator of the relativistic kinetic energy in the corresponding Hamiltonian, very frequently the corresponding (discrete) spectrum of energy eigenvalues cannot be determined analytically. Therefore, we show how to calculate, by some clever choice of basis vectors in the Hilbert space of solutions, for the rather large class of power-law potentials, at least (sometimes excellent) upper bounds on these energy eigenvalues, for the lowest-lying levels this even analytically. (author)

  4. Public budgets for energy RD&D and the effects on energy intensity and pollution levels.

    Science.gov (United States)

    Balsalobre, Daniel; Álvarez, Agustín; Cantos, José María

    2015-04-01

    This study, based on the N-shaped cubic model of the environmental Kuznets curve, analyzes the evolution of per capita greenhouse gas emissions (GHGpc) using not just economic growth but also public budgets dedicated to energy-oriented research development and demonstration (RD&D) and energy intensity. The empirical evidence, obtained from an econometric model of fixed effects for 28 OECD countries during 1994-2010, suggests that energy innovations help reduce GHGpc levels and mitigate the negative impact of energy intensity on environmental quality. When countries develop active energy RD&D policies, they can reduce both the rates of energy intensity and the level of GHGpc emissions. This paper incorporates a moderating variable to the econometric model that emphasizes the effect that GDP has on energy intensity. It also adds a variable that reflects the difference between countries that have made a greater economic effort in energy RD&D, which in turn corrects the GHG emissions resulting from the energy intensity of each country.

  5. Lamb shift of energy levels in quantum rings

    International Nuclear Information System (INIS)

    Kryuchkyan, G Yu; Kyriienko, O; Shelykh, I A

    2015-01-01

    We study the vacuum radiative corrections to energy levels of a confined electron in quantum rings. The calculations are provided for the Lamb shift of energy levels in a low-momentum region of virtual photons and for both one-dimensional and two-dimensional quantum rings. We show that contrary to the well known case of a hydrogen atom the value of the Lamb shift increases with the magnetic momentum quantum number m. We also investigate the dependence of the Lamb shift on magnetic flux piercing the ring and demonstrate a presence of magnetic-flux-dependent oscillations. For a one-dimensional ring the value of the shift strongly depends on the radius of the ring. It is small for semiconductor rings but can attain measurable quantities in natural organic ring-shape molecules, such as benzene, cycloalcanes and porphyrins. (paper)

  6. On Low Energy Levels in {sup 185}W

    Energy Technology Data Exchange (ETDEWEB)

    Malmskog, S G; Hoejeberg, M; Berg, V

    1969-02-15

    Gamma ray spectra in the decay of {sup 185}Ta and {sup 185m}W have been studied with Ge (Li) detectors. The {sup 185m}W isomeric transition at 131.6 keV is shown to be of E3 multipolarity. A level scheme of {sup 185}W is proposed with the following energy levels (energies in keV, spin and K quantum numbers in brackets): 0 (3/2{sup -} 3/2), 23.5 (1/2{sup -} 1/2), 65.9 (5/2{sup -} 3/2), 93.5 (3/2{sup -} 1/2) (uncertain), 173.9 (7/2{sup -} 3/2), 188.1 (5/2{sup -} 1/2), 197.5 (11/2{sup +} 11/2) , 243.5 (7/2{sup -} 7/2), and 390.8 (9/2{sup -} 7/2)

  7. Energy efficiency and exporting: Evidence from firm-level data

    International Nuclear Information System (INIS)

    Roy, Jayjit; Yasar, Mahmut

    2015-01-01

    While exporting firms and non-exporters have been compared across several dimensions, empirical comparisons on the basis of environmental performance are relatively few. Moreover, analyzing the environmental implications of firm-level exports is not trivial due to non-random selection into exporting. In this light, we examine the impact of exporting on firms' energy efficiency by resorting to an instrumental variables strategy based on a differencing approach (Pitt and Rosenzweig, 1990). Utilizing data from Indonesia, we find (i) exporting to reduce the use of fuels (relative to electricity) and (ii) concerns over endogeneity of exporting status to be relevant. - Highlights: • We examine the impact of exporting on firms' energy efficiency. • We employ cost share equations, firm-level data from Indonesia, and an instrumental variables strategy. • Exporting is found to reduce the use of fuels (relative to electricity).

  8. Equivalent Energy Density concept: A preliminary reexamination of a technique for equating thermal loads

    International Nuclear Information System (INIS)

    Ryder, E.E.

    1992-08-01

    Historical and projected inventories of spent fuel from commercial light-water nuclear reactors exhibit diverse decay characteristics and ages. This report summarizes a preliminary reexamination of a method for determining equivalent thermal loads for the range of spent fuel expected at a potential underground repository. The method, known at the Equivalent Energy Density (EED) concept, bases its equivalence criteria on the assumption that a given waste will produce worst-case thermomechanical effects equal to worst-case thermomechanical effects produced by a baseline waste, provided that the thermal energy deposited in the host rock over a specified deposition period is the same for both waste descriptions. To test this assumption, temperature histories at representative locations within the host rock were calculated using layouts defined by the EED concept and four deposition periods (20, 50, 100, and 300 years). It was found that the peak temperatures at near-field locations were best matched by the shorter deposition periods of 20 and 50 years. However, due to the sensitivity of the near-field environment to short-term canister-to-canister interactions, caution,should be used when choosing a near-field deposition period. At the location chosen to represent the far-field, a 300-year deposition period provided reasonable correspondence of peak temperature responses for all waste descriptions examined

  9. ATLAS Level-1 Calorimeter Trigger: Initial Timing and Energy Calibration

    CERN Document Server

    Childers, J T; The ATLAS collaboration

    2010-01-01

    The ATLAS Level-1 Calorimeter Trigger identifies high-pT objects in the Liquid Argon and Tile Calorimeters with a fixed latency of ~2.0 µs using a hardware-based, pipelined system built with custom electronics. The Preprocessor Module conditions and digitizes about 7200 pre-summed analogue signals from the calorimeters at the LHC bunch-crossing frequency of 40 MHz, and performs bunch-crossing identification (BCID) and deposited energy measurement for each input signal. This information is passed to further processors for object classification and total energy calculation, and the results used to make the Level-1 trigger decision for the ATLAS detector. The BCID and energy measurement in the trigger depend on precise timing adjustment to achieve correct sampling of the input signal peak. Test pulses from the calorimeters were analysed to derive the initial timing and energy calibration, and first data from the LHC restart in autumn 2009 and early 2010 were used for validation and further optimization. The res...

  10. Department of Energy low-level radioactive waste disposal concepts

    International Nuclear Information System (INIS)

    Ozaki, C.; Page, L.; Morreale, B.; Owens, C.

    1990-01-01

    The Department of Energy manages its low-level waste (LLW), regulated by DOE Order 5820.2A by using an overall systems approach. This systems approach provides an improved and consistent management system for all DOE LLW waste, from generation to disposal. This paper outlines six basic disposal concepts used in the systems approach, discusses issues associated with each of the concepts, and outlines both present and future disposal concepts used at six DOE sites

  11. Energy level alignment in Au/pentacene/PTCDA trilayer stacks

    OpenAIRE

    Sehati, P.; Braun, S.; Fahlman, M.

    2013-01-01

    Ultraviolet photoelectron spectroscopy is used to investigate the energy level alignment and molecular orientation at the interfaces in Au/pentacene/PTCDA trilayer stacks. We deduced a standing orientation for pentacene grown on Au while we conclude a flat lying geometry for PTCDA grown onto pentacene. We propose that the rough surface of polycrystalline Au induces the standing geometry in pentacene. It is further shown that in situ deposition of PTCDA on pentacene can influence the orientati...

  12. Development of a microlesson in teaching energy levels of atoms

    Science.gov (United States)

    Rodriguez, Cherilyn A.; Buan, Amelia T.

    2018-01-01

    Energy levels of atoms is one of the difficult topics in understanding atomic structure of matter. It appears tobe abstract, theoretical and needs visual representation and images. Hence, in this study a microlesson in teaching the high school chemistry concept on the energy levels of atoms is developed and validated. The researchers utilized backward curriculum design in planning the microlesson to meet the standards of the science K-12 curriculum. The planning process of the microlesson involved a) Identifying the learning competencies in K-12 science curriculum b) write learning objectives c) planning of assessment tools d) making a storyboard e) designing the microlesson and validate and revise the microlesson. The microlesson made use of varied resources in the internet from which the students accessed and collected information about energy levels of atoms. Working in groups, the students synthesized the information on how and why fireworks produce various colors of light through a post card. Findings of the study showed that there was an increase of achievement in learning the content and the students were highly motivated to learn chemistry. Furthermore, the students perceived that the microlesson helped them to understand the chemistry concept through the use of appropriate multimedia activities.

  13. Energy mesh optimization for multi-level calculation schemes

    International Nuclear Information System (INIS)

    Mosca, P.; Taofiki, A.; Bellier, P.; Prevost, A.

    2011-01-01

    The industrial calculations of third generation nuclear reactors are based on sophisticated strategies of homogenization and collapsing at different spatial and energetic levels. An important issue to ensure the quality of these calculation models is the choice of the collapsing energy mesh. In this work, we show a new approach to generate optimized energy meshes starting from the SHEM 281-group library. The optimization model is applied on 1D cylindrical cells and consists of finding an energy mesh which minimizes the errors between two successive collision probability calculations. The former is realized over the fine SHEM mesh with Livolant-Jeanpierre self-shielded cross sections and the latter is performed with collapsed cross sections over the energy mesh being optimized. The optimization is done by the particle swarm algorithm implemented in the code AEMC and multigroup flux solutions are obtained from standard APOLLO2 solvers. By this new approach, a set of new optimized meshes which encompass from 10 to 50 groups has been defined for PWR and BWR calculations. This set will allow users to adapt the energy detail of the solution to the complexity of the calculation (assembly, multi-assembly, two-dimensional whole core). Some preliminary verifications, in which the accuracy of the new meshes is measured compared to a direct 281-group calculation, show that the 30-group optimized mesh offers a good compromise between simulation time and accuracy for a standard 17 x 17 UO 2 assembly with and without control rods. (author)

  14. Environmental assessment for DOE permission for the off-loading and transportation of commercial low-level radioactive waste across the Savannah River Site

    International Nuclear Information System (INIS)

    1997-10-01

    The Department of Energy (DOE) prepared this Environmental Assessment (EA) to assess the potential environmental impacts associated with DOE allowing Chem-Nuclear Systems, L.L.C. (CNS) to off-load and transport low-level radioactive waste (LLW) packages across the Savannah River Site (SRS), located near Aiken, South Carolina, to the nearby CNS facility. The proposed action entails DOE granting permission to CNS to use SRS for landing shipping barges at the existing SRS boat ramp and off-loading trailered LLW packages for transportation across SRS to the CNS facility. Project activities would include modification of the SRS boat ramp on the Savannah River, as needed for off-loading activities, and construction of a bridge across Lower Three Runs. The proposed action also encompasses any similar future off-loading and transportation activities for LLW en route to the CNS facility. The National Environmental Policy Act requires the assessment of environmental consequences of Federal actions that may affect the quality of the human environment. Based on the potential for impacts described herein, DOE will either publish a Finding of No Significant Impact or prepare an Environmental Impact Statement (EIS)

  15. Response of the Water Level in a Well to Earth Tides and Atmospheric Loading Under Unconfined Conditions

    Science.gov (United States)

    Rojstaczer, Stuart; Riley, Francis S.

    1990-08-01

    The response of the water level in a well to Earth tides and atmospheric loading under unconfined conditions can be explained if the water level is controlled by the aquifer response averaged over the saturated depth of the well. Because vertical averaging tends to diminish the influence of the water table, the response is qualitatively similar to the response of a well under partially confined conditions. When the influence of well bore storage can be ignored, the response to Earth tides is strongly governed by a dimensionless aquifer frequency Q'u. The response to atmospheric loading is strongly governed by two dimensionless vertical fluid flow parameters: a dimensionless unsaturated zone frequency, R, and a dimensionless aquifer frequency Qu. The differences between Q'u and Qu are generally small for aquifers which are highly sensitive to Earth tides. When Q'u and Qu are large, the response of the well to Earth tides and atmospheric loading approaches the static response of the aquifer under confined conditions. At small values of Q'u and Qu, well response to Earth tides and atmospheric loading is strongly influenced by water table drainage. When R is large relative to Qu, the response to atmospheric loading is strongly influenced by attenuation and phase shift of the pneumatic pressure signal in the unsaturated zone. The presence of partial penetration retards phase advance in well response to Earth tides and atmospheric loading. When the theoretical response of a phreatic well to Earth tides and atmospheric loading is fit to the well response inferred from cross-spectral estimation, it is possible to obtain estimates of the pneumatic diffusivity of the unsaturated zone and the vertical hydraulic conductivity of the aquifer.

  16. Nested-scale discharge and groundwater level monitoring to improve predictions of flow route discharges and nitrate loads

    NARCIS (Netherlands)

    Velde, Y. van der; Rozemeijer, J.C.; Rooij, G.H.de; Geer, F.C. van; Torfs, P.J.J.F.; Louw, P.G.B. de

    2010-01-01

    Identifying effective measures to reduce nutrient loads of headwaters in lowland catchments requires a thorough understanding of flow routes of water and nutrients. In this paper we assess the value of nested-scale discharge and groundwater level measurements for predictions of catchment-scale

  17. Energy innovation and renewable energy consumption in the correction of air pollution levels

    International Nuclear Information System (INIS)

    Alvarez-Herranz, Agustin; Balsalobre-Lorente, Daniel; Shahbaz, Muhammad; Cantos, José María

    2017-01-01

    This study analyses the relationship between economic growth and environmental pollution. Specifically, it investigates the presence of an environmental Kuznets curve (EKC) in 17 OECD countries over the period of 1990–2012. The results confirm the existence of an N-shaped EKC relationship between income and environmental degradation. The study offers a novel methodological contribution that makes it possible to explain the environmental pollution process through the analysis of low-carbon technologies. This demonstrates how income levels affect energy consumption and how higher energy demand leads to a larger share of fossil sources in the energy mix and, thus, increased greenhouse gas (GHG) emissions. The effect on per capita GHG emissions is explored in a model containing a dampening variable that moderates the relationship between energy consumption and income. This empirical evidence helps to explain the interaction between energy regulation, economic growth and carbon emissions. This study also confirms the positive effect that energy innovation process exerts on environmental pollution. Finally, it is noted that renewable energy sources help to improve air quality. - Highlights: • An inverted N-shaped relationship between economic growth and environmental degradation in OECD countries is validated. • Energy regulatory policies exert positive effect on environmental quality. • Energy innovation processes delays the technical obsolescence. • Energy innovation process requires a time lag to become fully efficient.

  18. Maximal sustained levels of energy expenditure in humans during exercise.

    Science.gov (United States)

    Cooper, Jamie A; Nguyen, David D; Ruby, Brent C; Schoeller, Dale A

    2011-12-01

    Migrating birds have been able to sustain an energy expenditure (EE) that is five times their basal metabolic rate. Although humans can readily reach these levels, it is not yet clear what levels can be sustained for several days. The study's purposes were 1) to determine the upper limits of human EE and whether or not those levels can be sustained without inducing catabolism of body tissues and 2) to determine whether initial body weight is related to the levels that can be sustained. We compiled data on documented EE as measured by doubly labeled water during high levels of physical activity (minimum of five consecutive days). We calculated the physical activity level (PAL) of each individual studied (PAL = total EE / basal metabolic rate) from the published data. Correlations were run to examine the relationship between initial body weight and body weight lost with both total EE and PAL. The uppermost limit of EE was a peak PAL of 6.94 that was sustained for 10 consecutive days of a 95-d race. Only two studies reported PALs above 5.0; however, significant decreases in body mass were found in each study (0.45-1.39 kg·wk(-1) of weight loss). To test whether initial weight affects the ability to sustain high PALs, we found a significant positive correlation between TEE and initial body weight (r = 0.46, P body weight (r = 0.27, not statistically significant). Some elite humans are able to sustain PALs above 5.0 for a minimum of 10 d. Although significant decreases in body weight occur at this level, catabolism of body tissue may be preventable in situations with proper energy intake. Further, initial body weight does not seem to affect the sustainability of PALs.

  19. Evaluating C-RAN Fronthaul Functional Splits in Terms of Network Level Energy and Cost Savings

    DEFF Research Database (Denmark)

    Checko, Aleksandra; Popovska Avramova, Andrijana; Berger, Michael Stübert

    2016-01-01

    The placement of the complete baseband processing in a centralized pool results in high data rate requirement and inflexibility of the fronthaul network, which challenges the energy and cost effectiveness of the cloud radio access network (C-RAN). Recently, redesign of the C-RAN through functional...... split in the baseband processing chain has been proposed to overcome these challenges. This paper evaluates, by mathematical and simulation methods, different splits with respect to network level energy and cost efficiency having in the mind the expected quality of service.The proposed mathematical...... model quantifies the multiplexing gains and the trade-offs between centralization and decentralization concerning the cost of the pool, fronthaul network capacity and resource utilization. The event-based simulation captures the influence of the traffic load dynamics and traffic type variation...

  20. New values for some 4He I 1snl energy levels, ionization energies, and Lamb shifts

    International Nuclear Information System (INIS)

    Martin, W.C.

    1984-01-01

    Recent experimental determinations of energy separations within the 1snl term system (n = 2--6) have been used to reevaluate 35 levels. Most of the levels have estimated errors less than 0.001 cm -1 relative to the 2 3 P levels. Addition of accurate theoretical term values (ionization energies) available for several 1snl levels to the corresponding experimental level values gives generally consistent values for the principal ionization energy (E/sub I/). The theoretical energies are further confirmed by the agreement of the weighted average of seven of these E/sub I/ values with a value obtained by fitting Ritz formulas to three accurately determined 1snl series; the suggested new E/sub I/ is 198 310.7745(40) cm -1 on an energy scale fixed by the value 171 135.0000 cm -1 for 2 1 P. Lamb shifts are derived for the 2, 3, 4 3 S 1 , 2 1 S 0 , 2 3 P 1 , and 2 1 P 1 levels as differences between experimental term values obtained with the new E/sub I/ and corresponding calculated term values not including Lamb shifts. The experimental and calculated values for the 1s 2 1 S 0 ground level relative to the present 1snl excited-level system are 0.00 +- 0.15 and 0.073 +- 0.009 cm -1 , respectively, so that a approx.20-fold increase in the experimental accuracy would be required to test the calculated ground-level Lamb shift

  1. Optimization of 10 kW solar photovoltaic – diesel generator hybrid energy system for different load factors at Jaisalmer location of Rajasthan, India

    Science.gov (United States)

    Saraswat, S. K.; Rao, K. V. S.

    2018-03-01

    Jaisalmer town in Rajasthan, India is having annual average solar insolation of 5.80 kWh/m2/day and 270 – 300 clear sky days in a year. A 10 kW off-grid hybrid energy system (HES) consisting of solar photovoltaic panels – diesel generator – bidirectional converter and batteries with zero percentage loss of load for Jaisalmer is designed using HOMER (version 3.4.3) software. Different system load factors of 0.33, 0.50, 0.67, 0.83 and 1 corresponding to fraction of running hours per day of the system are considered. The system is analyzed for all three aspects, namely, electrical, economic and emission point of view. Least levelized cost of electricity (LCOE) of Rs. 8.43/kWh is obtained at a load factor value of 0.5. If diesel generator alone (without Solar PV) is used to fulfil the demand for a load factor of 0.5the value of LCOE is obtained Rs.19.23/kWh. Comparison of results obtained for HES and diesel generator are made for load factor of 0.5 and 1.

  2. Critical loads of nitrogen deposition and critical levels of atmospheric ammonia for semi-natural Mediterranean evergreen woodlands

    Directory of Open Access Journals (Sweden)

    P. Pinho

    2012-03-01

    Full Text Available Nitrogen (N has emerged in recent years as a key factor associated with global changes, with impacts on biodiversity, ecosystems functioning and human health. In order to ameliorate the effects of excessive N, safety thresholds such as critical loads (deposition fluxes and levels (concentrations can be established. Few studies have assessed these thresholds for semi-natural Mediterranean ecosystems. Our objective was therefore to determine the critical loads of N deposition and long-term critical levels of atmospheric ammonia for semi-natural Mediterranean evergreen woodlands. We have considered changes in epiphytic lichen communities, one of the most sensitive comunity indicators of excessive N in the atmosphere. Based on a classification of lichen species according to their tolerance to N we grouped species into response functional groups, which we used as a tool to determine the critical loads and levels. This was done for a Mediterranean climate in evergreen cork-oak woodlands, based on the relation between lichen functional diversity and modelled N deposition for critical loads and measured annual atmospheric ammonia concentrations for critical levels, evaluated downwind from a reduced N source (a cattle barn. Modelling the highly significant relationship between lichen functional groups and annual atmospheric ammonia concentration showed the critical level to be below 1.9 μg m−3, in agreement with recent studies for other ecosystems. Modelling the highly significant relationship between lichen functional groups and N deposition showed that the critical load was lower than 26 kg (N ha−1 yr−1, which is within the upper range established for other semi-natural ecosystems. Taking into account the high sensitivity of lichen communities to excessive N, these values should aid development of policies to protect Mediterranean woodlands from the initial effects of excessive N.

  3. Operation and thermal loading of three-level Neutral-Point-Clamped wind power converter under various grid faults

    DEFF Research Database (Denmark)

    Ma, Ke; Blaabjerg, Frede; Liserre, Marco

    2012-01-01

    In order to fulfill the continuous growing grid-side demands, the full-scale power converters are becoming more and more popular in the wind power application. Nevertheless, the more severe loading of the power semiconductor devices in the full-scale power converters, especially during Low Voltage...... Ride Through (LVRT) operation under grid faults, may compromise the reliability of the system and consequently further increase its cost. In this paper, the impact of various grid faults on a three-level Neutral-Point-Clamped (3L-NPC) grid-converter in terms of thermal loading of power semiconductor...

  4. Peak load demand forecasting using two-level discrete wavelet decomposition and neural network algorithm

    Science.gov (United States)

    Bunnoon, Pituk; Chalermyanont, Kusumal; Limsakul, Chusak

    2010-02-01

    This paper proposed the discrete transform and neural network algorithms to obtain the monthly peak load demand in mid term load forecasting. The mother wavelet daubechies2 (db2) is employed to decomposed, high pass filter and low pass filter signals from the original signal before using feed forward back propagation neural network to determine the forecasting results. The historical data records in 1997-2007 of Electricity Generating Authority of Thailand (EGAT) is used as reference. In this study, historical information of peak load demand(MW), mean temperature(Tmean), consumer price index (CPI), and industrial index (economic:IDI) are used as feature inputs of the network. The experimental results show that the Mean Absolute Percentage Error (MAPE) is approximately 4.32%. This forecasting results can be used for fuel planning and unit commitment of the power system in the future.

  5. Enhancing multiphoton upconversion through energy clustering at sublattice level

    Science.gov (United States)

    Wang, Juan; Deng, Renren; MacDonald, Mark A.; Chen, Bolei; Yuan, Jikang; Wang, Feng; Chi, Dongzhi; Andy Hor, Tzi Sum; Zhang, Peng; Liu, Guokui; Han, Yu; Liu, Xiaogang

    2014-02-01

    The applications of lanthanide-doped upconversionnanocrystals in biological imaging, photonics, photovoltaics and therapeutics have fuelled a growing demand for rational control over the emission profiles of the nanocrystals. A common strategy for tuning upconversion luminescence is to control the doping concentration of lanthanide ions. However, the phenomenon of concentration quenching of the excited state at high doping levels poses a significant constraint. Thus, the lanthanide ions have to be stringently kept at relatively low concentrations to minimize luminescence quenching. Here we describe a new class of upconversion nanocrystals adopting an orthorhombic crystallographic structure in which the lanthanide ions are distributed in arrays of tetrad clusters. Importantly, this unique arrangement enables the preservation of excitation energy within the sublattice domain and effectively minimizes the migration of excitation energy to defects, even in stoichiometric compounds with a high Yb3+ content (calculated as 98 mol%). This allows us to generate an unusual four-photon-promoted violet upconversion emission from Er3+ with an intensity that is more than eight times higher than previously reported. Our results highlight that the approach to enhancing upconversion through energy clustering at the sublattice level may provide new opportunities for light-triggered biological reactions and photodynamic therapy.

  6. Enhancing multiphoton upconversion through energy clustering at sublattice level

    KAUST Repository

    Wang, Juan

    2013-11-24

    The applications of lanthanide-doped upconversionnanocrystals in biological imaging, photonics, photovoltaics and therapeutics have fuelled a growing demand for rational control over the emission profiles of the nanocrystals. A common strategy for tuning upconversion luminescence is to control the doping concentration of lanthanide ions. However, the phenomenon of concentration quenching of the excited state at high doping levels poses a significant constraint. Thus, the lanthanide ions have to be stringently kept at relatively low concentrations to minimize luminescence quenching. Here we describe a new class of upconversion nanocrystals adopting an orthorhombic crystallographic structure in which the lanthanide ions are distributed in arrays of tetrad clusters. Importantly, this unique arrangement enables the preservation of excitation energy within the sublattice domain and effectively minimizes the migration of excitation energy to defects, even in stoichiometric compounds with a high Yb 3+ content (calculated as 98 mol%). This allows us to generate an unusual four-photon-promoted violet upconversion emission from Er 3+ with an intensity that is more than eight times higher than previously reported. Our results highlight that the approach to enhancing upconversion through energy clustering at the sublattice level may provide new opportunities for light-triggered biological reactions and photodynamic therapy. © 2014 Macmillan Publishers Limited. All rights reserved.

  7. Effects of Seismological and Soil Parameters on Earthquake Energy demand in Level Ground Sand Deposits

    Science.gov (United States)

    nabili, sara; shahbazi majd, nafiseh

    2013-04-01

    Liquefaction has been a source of major damages during severe earthquakes. To evaluate this phenomenon there are several stress, strain and energy based approaches. Use of the energy method has been more focused by researchers due to its advantages with respect to other approaches. The use of the energy concept to define the liquefaction potential is validated through laboratory element and centrifuge tests as well as field studies. This approach is based on the hypothesis that pore pressure buildup is directly related to the dissipated energy in sands which is the accumulated areas between the stress-strain loops. Numerous investigations were performed to find a relationship which correlates the dissipated energy to the soil parameters, but there are not sufficient studies to relate this dissipated energy, known as demand energy, concurrently, to the seismological and the soil parameters. The aim of this paper is to investigate the dependency of the demand energy in sands to seismological and the soil parameters. To perform this task, an effective stress analysis has been executed using FLAC finite difference program. Finn model, which is a built-in constitutive model implemented in FLAC program, was utilized. Since an important stage to predict the liquefaction is the prediction of excess pore water pressure at a given point, a simple numerical framework is presented to assess its generation during a cyclic loading in a given centrifuge test. According to the results, predicted excess pore water pressures did not closely match to the measured excess pore water pressure values in the centrifuge test but they can be used in the numerical assessment of excess pore water pressure with an acceptable degree of preciseness. Subsequently, the centrifuge model was reanalyzed using several real earthquake acceleration records with different seismological parameters such as earthquake magnitude and Hypocentral distance. The accumulated energies (demand energy) dissipated in

  8. Low-Level RF Control of Microphonics in Superconducting Spoke-Loaded Cavities

    International Nuclear Information System (INIS)

    Conway, Z.A.; Kelly, M.P.; Sharamentov, S.I.; Shepard, K.W.; Davis, G.; Delayen, Jean; Doolittle, Lawrence

    2007-01-01

    This paper presents the results of cw RF frequency control and RF phase-stabilization experiments performed with a piezoelectric fast tuner mechanically coupled to a superconducting, 345 MHz, < = 0.5 triple-spoke-loaded cavity operating at 4.2K. The piezoelectric fast tuner damped low-frequency microphonic-noise by an order of magnitude. Two methods of RF phase-stabilization were characterized: overcoupling with negative phase feedback, and also fast mechanical tuner feedback. The = 0.5 triple-spoke-loaded cavity RF field amplitude and phase errors were controlled to ±0.5% and ±30 respectively.

  9. Loading Analysis of Modular Multi-level Converter for Offshore High-voltage DC Application under Various Grid Faults

    DEFF Research Database (Denmark)

    Liu, Hui; Ma, Ke; Loh, Poh Chiang

    2016-01-01

    challenges but may also result in overstressed components for the modular multi-level converter. However, the thermal loading of the modular multi-level converter under various grid faults has not yet been clarified. In this article, the power loss and thermal performance of the modular multi-level converter...... low-voltage ride-through strongly depend on the types and severity values of grid voltage dips. The thermal distribution among the three phases of the modular multi-level converter may be quite uneven, and some devices are much more stressed than the normal operating condition, which may...

  10. Energy levels and transition probabilities for Fe XXV ions

    Energy Technology Data Exchange (ETDEWEB)

    Norrington, P.H.; Kingston, A.E.; Boone, A.W. [Department of Applied Maths and Theoretical Physics, Queen' s University, Belfast BT7 1NN (United Kingdom)

    2000-05-14

    The energy levels of the 1s{sup 2}, 1s2l and 1s3l states of helium-like iron Fe XXV have been calculated using two sets of configuration-interaction wavefunctions. One set of wavefunctions was generated using the fully relativistic GRASP code and the other was obtained using CIV3, in which relativistic effects are introduced using the Breit-Pauli approximation. For transitions from the ground state to the n=2 and 3 states and for transitions between the n=2 and 3 states, the calculated excitation energies obtained by these two independent methods are in very good agreement and there is good agreement between these results and recent theoretical and experimental results. However, there is considerable disagreement between the various excitation energies for the transitions among the n=2 and also among the n=3 states. The two sets of wavefunctions are also used to calculate the E1, E2, M1 and M2 transition probabilities between all of the 1s{sup 2}, 1s2l and 1s3l states of helium-like iron Fe XXV. The results from the two calculations are found to be similar and to compare very well with other recent results for {delta}n=1 or 2 transitions. For {delta}n=0 transitions the agreement is much less satisfactory; this is mainly due to differences in the excitation energies. (author)

  11. Multi-Level Experimental and Analytical Evaluation of Two Composite Energy Absorbers

    Science.gov (United States)

    Jackson, Karen E.; Littell, Justin D.; Fasanella, Edwin L.; Annett, Martin S.; Seal, Michael D., II

    2015-01-01

    Two composite energy absorbers were developed and evaluated at NASA Langley Research Center through multi-level testing and simulation performed under the Transport Rotorcraft Airframe Crash Testbed (TRACT) research program. A conical-shaped energy absorber, designated the conusoid, was evaluated that consisted of four layers of hybrid carbon-Kevlar plain weave fabric oriented at [+45 deg/-45 deg/-45 deg/+45 deg] with respect to the vertical, or crush, direction. A sinusoidal-shaped energy absorber, designated the sinusoid, was developed that consisted of hybrid carbon-Kevlar plain weave fabric face sheets, two layers for each face sheet oriented at +/-45deg with respect to the vertical direction and a closed-cell ELFOAM P200 polyisocyanurate (2.0-lb/cu ft) foam core. The design goal for the energy absorbers was to achieve average floor-level accelerations of between 25- and 40-g during the full-scale crash test of a retrofitted CH-46E helicopter airframe, designated TRACT 2. Variations in both designs were assessed through dynamic crush testing of component specimens. Once the designs were finalized, subfloor beams of each configuration were fabricated and retrofitted into a barrel section of a CH-46E helicopter. A vertical drop test of the barrel section was conducted onto concrete to evaluate the performance of the energy absorbers prior to retrofit into TRACT 2. The retrofitted airframe was crash tested under combined forward and vertical velocity conditions onto soil, which is characterized as a sand/clay mixture. Finite element models were developed of all test articles and simulations were performed using LS-DYNA, a commercial nonlinear explicit transient dynamic finite element code. Test-analysis results are presented for each energy absorber as comparisons of time-history responses, as well as predicted and experimental structural deformations and progressive damage under impact loading for each evaluation level.

  12. Effect of Islanding and Telecontrolled Switches on Distribution System Reliability Considering Load and Green-Energy Fluctuations

    Directory of Open Access Journals (Sweden)

    Stefania Conti

    2016-05-01

    Full Text Available To improve electrical distribution network reliability, some portions of the network could operate in autonomous mode, provided that the related technical issues are addressed. More specifically, when there is not a path from those portions to the primary substation due to a fault in the network, such portions could be disconnected from the main network and supplied by local generation only. Such a mode of operation is known as “intentional islanding” and its effectiveness, in terms of adequacy, depends on the ability of the local generation to meet the island’s load. In fact, the ratio between the available local generation and load demand can frequently change during islanding due to load variations and, especially, due to the strongly irregular behavior of the primary energy sources of renewable generators. This paper proposes an analytical formulation to assess local generation adequacy during intentional islanding, accounting for the aforementioned variations. More specifically, the fluctuations of load and green-energy generators during islanding are modeled by means of Markov chains, whose output quantities are encompassed in the proposed analytical formulation. Such a formulation is used by the analytical equations of load points’ outage rate and duration. The evaluation of the reliability indices accounts for a protection scheme based on an appropriate communication infrastructure. Therefore, a brief overview on the telecommunications technologies has been presented with reference to their suitability for the specific application. In particular, distribution network safety issues have been considered as the main concern. The results show that neglecting load and generation fluctuations leads to a strong overestimation of the ability of distributed generators to meet the island load. Through a case study it is observed that the error on the load point outage rate is greater than the one affecting the outage duration.

  13. Serum transferrin levels in children with protein-energy malnutrition

    Directory of Open Access Journals (Sweden)

    Selime Aydoğdu

    2013-03-01

    Full Text Available Objective: Although the diagnosis of patients with severemalnutrition is easy, it is very difficult to recognize patientswith mild and moderate malnutrition. A variety of methodsattempts to develop for early diagnosis of these cases.In this study, we evaluated the serum transferrin and albuminlevels in children with mild, moderate and severeprotein-energy malnutrition (PEM.Materials and methods: Children admitted to our policlinic,aged between 3 and 25 months, 45 subjects withPEM and 39 healthy subjects (control group were evaluated.According to the Gomez, Waterlow and Kanawatisubjects with PEM were divided in 3 subgroups mild,moderate and severe PEM. Anthropometric measurementsand biochemical results of 4 groups were compared.Results: For albumin levels in mild to moderate PEMgroups, 37.7% sensitivity, and 28.5% specificity, positivepredictive value 54%; negative predictive value 16.6%was found. For severe PEM sensitivity, specificity, positivepredictive value and negative predictive value were71%, 62.5%, 45%, and 83.3% respectively.With respect to the levels of transferrin, a significant differencewas found between mild PEM-control and moderatePEM-control groups (p0.05.Conclusion: Our study results showed that albumin isa weak indicator in mild-moderate PEM. In these cases,serum transferrin level reduces before decreasing of albuminlevel, thus it may be an early sensitive finding thatcan be used as a sensitive parameter in the diagnosis ofearly stages of malnutrition.Key words: Protein energy malnutrition, children, albumin,transferrin

  14. Awareness and Cognitive Load Levels of Teacher Candidates towards Student Products Made by Digital Storytelling

    Science.gov (United States)

    Kilic, Figen

    2014-01-01

    The purpose of this research is to assess the student products created by digital storytelling, and to determine the awareness towards learning the topic and the cognitive loads of students during the process. Research was performed with a total of 52 teacher candidates attending 2nd class at "Classroom Teacher" department of Mersin…

  15. Emission of formaldehyde by particleboard : effect of ventilation rate and loading on air-contamination levels

    Science.gov (United States)

    George E. Myers; Muneo Nagaoka

    1981-01-01

    Dynamic tests for determining the formaldehyde emission behavior of UF-bonded boards involve the measurement of formaldehyde concentration in the air within a vessel which contains a specified board loading L (m2 of board area per m3 of vessel free volume) and is being ventilated at a specified air exchange rate N (hr.-1). Such tests constitute a primary...

  16. Global gray water footprint and water pollution levels related to anthropogenic nitrogen loads to fresh water

    NARCIS (Netherlands)

    Mekonnen, Mesfin; Hoekstra, Arjen Ysbert

    2015-01-01

    This is the first global assessment of nitrogen-related water pollution in river basins with a specification of the pollution by economic sector, and by crop for the agricultural sector. At a spatial resolution of 5 by 5 arc minute, we estimate anthropogenic nitrogen (N) loads to freshwater,

  17. Plastic collapse and energy absorption of circular filled tubes under quasi-static loads by computational analysis

    Energy Technology Data Exchange (ETDEWEB)

    Beng, Yeo Kiam; Tzeng, Woo Wen [Universiti Malaysia Sabah, Sabah (Malaysia)

    2017-02-15

    This study presents the finite element analysis of plastic collapse and energy absorption of polyurethane-filled aluminium circular tubes under quasi-static transverse loading. Increasing focuses were given to impact damage of structures where energy absorbed during impact could be controlled to avoid total structure collapse of energy absorbers and devices designed to dissipate energy. ABAQUS finite element analysis application was utilized for modelling and simulating the polyurethane-filled aluminium tubes, different set of diameterto- thickness ratios and span lengths, subjected to transverse three-point-bending load. Different sets of polyurethane-filled aluminium tubes subjected to the transverse loading were modelled and simulated. The failure modes and mechanisms of filled tubes and its capabilities as energy absorbers to further improve and strengthening of empty tube were also identified. The results showed that plastic deformation response was affected by the geometric constraints and parameters of the specimens. The diameter-to-thickness ratio and span lengths had shown to play crucial role in optimizing the PU-filled tube as energy absorber.

  18. A High Precision Artificial Neural Networks Model for Short-Term Energy Load Forecasting

    Directory of Open Access Journals (Sweden)

    Ping-Huan Kuo

    2018-01-01

    Full Text Available One of the most important research topics in smart grid technology is load forecasting, because accuracy of load forecasting highly influences reliability of the smart grid systems. In the past, load forecasting was obtained by traditional analysis techniques such as time series analysis and linear regression. Since the load forecast focuses on aggregated electricity consumption patterns, researchers have recently integrated deep learning approaches with machine learning techniques. In this study, an accurate deep neural network algorithm for short-term load forecasting (STLF is introduced. The forecasting performance of proposed algorithm is compared with performances of five artificial intelligence algorithms that are commonly used in load forecasting. The Mean Absolute Percentage Error (MAPE and Cumulative Variation of Root Mean Square Error (CV-RMSE are used as accuracy evaluation indexes. The experiment results show that MAPE and CV-RMSE of proposed algorithm are 9.77% and 11.66%, respectively, displaying very high forecasting accuracy.

  19. Spectrum and energy levels of four-times-ionized niobium

    International Nuclear Information System (INIS)

    Kagan, D.T.; Conway, J.G.; Meinders, E.

    1981-01-01

    The 4p 6 nl spectrum of Nb 4+ was measured and analyzed. The spectrum was excited in a vacuum sliding spark source with a peak current of 800 A and a pulse width of 70 μsec. The analysis of the spectrum has extended the 12 known lines to 84 and the 10 known levels to 30. The ionization energy was calculated to be 407897 +- 40 cm -1 . There is strong evidence that the 4p 5 4d 2 configurations interacts strongly with the 4p 6 nf configuration. In addition, the hyperfine splitting of the 4p 6 6s level has been observed and measured to be 1.1 cm -1

  20. Sizing community energy storage systems to reduce transformer overloading with emphasis on plug-in electric vehicle loads

    Science.gov (United States)

    Trowler, Derik Wesley

    The research objective of this study was to develop a sizing method for community energy storage systems with emphasis on preventing distribution transformer overloading due to plug-in electric vehicle charging. The method as developed showed the formulation of a diversified load profile based upon residential load data for several customers on the American Electric Power system. Once a load profile was obtained, plug-in electric vehicle charging scenarios which were based upon expected adoption and charging trends were superimposed on the load profile to show situations where transformers (in particular 25 kVA, 50 kVA, and 100 kVA) would be overloaded during peak hours. Once the total load profiles were derived, the energy and power requirements of community energy storage systems were calculated for a number of scenarios with different combinations of numbers of homes and plug-in electric vehicles. The results were recorded and illustrated into charts so that one could determine the minimum size per application. Other topics that were covered in this thesis were the state of the art and future trends in plug-in electric vehicle and battery chemistry adoption and development. The goal of the literature review was to confirm the already suspected notion that Li-ion batteries are best suited and soon to be most cost-effective solution for applications requiring small, efficient, reliable, and light-weight battery systems such as plug-in electric vehicles and community energy storage systems. This thesis also includes a chapter showing system modeling in MATLAB/SimulinkRTM. All in all, this thesis covers a wide variety of considerations involved in the designing and deploying of community energy storage systems intended to mitigate the effects of distribution transformer overloading.

  1. Energy efficiency, human behavior, and economic growth: Challenges to cutting energy demand to sustainable levels

    Science.gov (United States)

    Santarius, Tilman

    2015-03-01

    Increasing energy efficiency in households, transportation, industries, and services is an important strategy to reduce energy service demand to levels that allow the steep reduction of greenhouse gases, and a full fledged switch of energy systems to a renewable basis. Yet, technological efficiency improvements may generate so-called rebound effects, which may `eat up' parts of the technical savings potential. This article provides a comprehensive review of existing research on these effects, raises critiques, and points out open questions. It introduces micro-economic rebound effect and suggests extending consumer-side analysis to incorporate potential `psychological rebound effects.' It then discusses meso-economic rebound effects, i.e. producer-side and market-level rebounds, which so far have achieved little attention in the literature. Finally, the article critically reviews evidence for macro-economic rebound effects as energy efficiency-induced economic growth impacts. For all three categories, the article summarizes assessments of their potential quantitative scope, while pointing out remaining methodological weaknesses and open questions. As a rough "rule of thumb", in the long term and on gross average, only half the technical savings potential of across-the-board efficiency improvements may actually be achieved in the real world. Policies that aim at cutting energy service demand to sustainable levels are well advised to take due note of detrimental behavioral and economic growth impacts, and should foster policies and measures that can contain them.

  2. Energy efficiency, human behavior, and economic growth: Challenges to cutting energy demand to sustainable levels

    Energy Technology Data Exchange (ETDEWEB)

    Santarius, Tilman, E-mail: tilman@santarius.de [Visiting Scholar, Institute of European Studies and Energy and Resources Group, University of California, Berkeley, 310 Barrows Hall, Berkeley, CA 94720-3050 (United States)

    2015-03-30

    Increasing energy efficiency in households, transportation, industries, and services is an important strategy to reduce energy service demand to levels that allow the steep reduction of greenhouse gases, and a full fledged switch of energy systems to a renewable basis. Yet, technological efficiency improvements may generate so-called rebound effects, which may ‘eat up’ parts of the technical savings potential. This article provides a comprehensive review of existing research on these effects, raises critiques, and points out open questions. It introduces micro-economic rebound effect and suggests extending consumer-side analysis to incorporate potential ‘psychological rebound effects.’ It then discusses meso-economic rebound effects, i.e. producer-side and market-level rebounds, which so far have achieved little attention in the literature. Finally, the article critically reviews evidence for macro-economic rebound effects as energy efficiency-induced economic growth impacts. For all three categories, the article summarizes assessments of their potential quantitative scope, while pointing out remaining methodological weaknesses and open questions. As a rough “rule of thumb”, in the long term and on gross average, only half the technical savings potential of across-the-board efficiency improvements may actually be achieved in the real world. Policies that aim at cutting energy service demand to sustainable levels are well advised to take due note of detrimental behavioral and economic growth impacts, and should foster policies and measures that can contain them.

  3. Energy Levels, wavelengths and hyperfine structure measurements of Sc II

    Science.gov (United States)

    Hala, Fnu; Nave, Gillian

    2018-01-01

    Lines of singly ionized Scandium (Sc II) along with other Iron group elements have been observed [1] in the region surrounding the massive star Eta Carinae [2,3] called the strontium filament (SrF). The last extensive analysis of Sc II was the four-decade old work of Johansson & Litzen [4], using low-resolution grating spectroscopy. To update and extend the Sc II spectra, we have made observation of Sc/Ar, Sc/Ne and Sc/Ge/Ar hollow cathode emission spectrum on the NIST high resolution FT700 UV/Vis and 2 m UV/Vis/IR Fourier transform spectrometers (FTS). More than 850 Sc II lines have been measured in the wavelength range of 187 nm to 3.2 μm. connecting a total of 152 energy levels. The present work also focuses to resolve hyperfine structure (HFS) in Sc II lines. We aim to obtain accurate transition wavelengths, improved energy levels and HFS constants of Sc II. The latest results from work in progress will be presented.Reference[1] Hartman H, Gull T, Johansson S and Smith N 2004 Astron. Astrophys. 419 215[2] Smith N, Morse J A and Gull T R 2004 Astrophys. J. 605 405[3] Davidson K and Humphreys R M 1997 Annu. Rev. Astron. Astrophys. 35[4] Johansson S and Litzén U 1980 Phys. Scr. 22 49

  4. Calculation of almost all energy levels of baryons

    Directory of Open Access Journals (Sweden)

    Mario Everaldo de Souza

    2011-03-01

    Full Text Available It is considered that the effective  interaction between any two quarks of a baryon can be approximately described by a simple harmonic potential. The problem is firstly solved in Cartesian coordinates in order to find the energy levels irrespective of their angular momenta. Then, the problem is also solved in polar cylindrical coordinates in order to take into account the angular momenta of the levels. Comparing the two solutions, a correspondence is made between the angular momenta and parities for almost all experimentally determined levels. The agreement with the experimental data is quite impressive and, in general, the discrepancy between calculated and experimental values is below 5%. A couple of levels of $Delta$, $N$, $Sigma^{pm}$, and $Omega$ present discrepacies between 6.7% and 12.5% ($N(1655$, $N(1440$, $N(1675$, $N(1685$, $N(1700$, $N(1710$, $N(1720$, $N(1990$, $N(2600$, $Delta(1700$, $Delta(2000$, $Delta(2300$, $Sigma^{pm}(1189$, $Lambda(1520$, $Omega(1672$ and $Omega(2250$.Received: 6 June 2011, Accepted: 13 July 2011; Edited by: D. Restrepo; Reviewed by: J. H. Muñoz, Universidad del Tolima, Ibagué, Colombia and Centro Brasileiro de Pesquisas Fisica; DOI: http://dx.doi.org/10.4279/PIP.030003Cite as: M. E. de Souza, Papers in Physics 3, 030003 (2011

  5. Basin Testing of Wave Energy Converters in Trondheim: Investigation of Mooring Loads and Implications for Wider Research

    Directory of Open Access Journals (Sweden)

    Vladimir Krivtsov

    2014-04-01

    Full Text Available This paper describes the physical model testing of an array of wave energy devices undertaken in the NTNU (Norwegian University of Science and Technology Trondheim basin between 8 and 20 October 2008 funded under the EU Hydralabs III initiative, and provides an analysis of the extreme mooring loads. Tests were completed at 1/20 scale on a single oscillating water column device and on close-packed arrays of three and five devices following calibration of instrumentation and the wave and current test environment. One wave energy converter (WEC was fully instrumented with mooring line load cells, optical motion tracker and accelerometers and tested in regular waves, short- and long-crested irregular waves and current. The wave and current test regimes were measured by six wave probes and a current meter. Arrays of three and five similar WECs, with identical mooring systems, were tested under similar environmental loading with partial monitoring of mooring forces and motions. The majority of loads on the mooring lines appeared to be broadly consistent with both logistic and normal distribution; whilst the right tail appeared to conform to the extreme value distribution. Comparison of the loads at different configurations of WEC arrays suggests that the results are broadly consistent with the hypothesis that the mooring loads should differ. In particular; the results from the tests in short crested seas conditions give an indication that peak loads in a multi WEC array may be considerably higher than in 1-WEC configuration. The test campaign has contributed essential data to the development of Simulink™ and Orcaflex™ models of devices, which include mooring system interactions, and data have also been obtained for inter-tank comparisons, studies of scale effects and validation of mooring system numerical models. It is hoped that this paper will help to draw the attention of a wider scientific community to the dataset freely available from the

  6. Contribution of Hfe expression in macrophages to the regulation of hepatic hepcidin levels and iron loading

    OpenAIRE

    Makui, Hortence; Soares, Ricardo J.; Jiang, Wenlei; Constante, Marco; Santos, Manuela M.

    2005-01-01

    Hereditary hemochromatosis (HH), an iron overload disease associated with mutations in the HFE gene, is characterized by increased intestinal iron absorption and consequent deposition of excess iron, primarily in the liver. Patients with HH and Hfe-deficient (Hfe−/−) mice manifest inappropriate expression of the iron absorption regulator hepcidin, a peptide hormone produced by the liver in response to iron loading. In this study, we investigated the contribution of Hfe expression in macrophag...

  7. Processes of energy recovery / energy valorization at low temperature levels. State of the art. Extended abstract

    International Nuclear Information System (INIS)

    Manificat, A.; Megret, O.

    2012-09-01

    This study aims to realize a state of art of the processes of energy recovery at low level of temperature and their valorizations. The information provided will target particularly the thermal systems of waste and biomass treatment. After reminding the adequate context of development with these solutions and define the scope of the current work, the study begins with the definition of different concepts such as low-grade heat (fatal energy) and exergy, and also the presentation of the fiscal environment as well as the economic and regulatory situation, with information about the TGAP, prices of energy and energy efficiency. The second chapter focuses on the different sources of energy at low temperature level that can be recoverable in order to assess their potentials and their characteristics. The Determination of the temperature range of these energy sources will be put in relation with the needs and demands of users from different industrial sectors. The third part of the study is a review of various technologies for energy recovery and valorization at low temperature. It is useful to distinguish different types of heat exchangers interesting to implement. Moreover, innovative processes allow us to consider new perspectives other than a direct use of heat recovered. For example, we can take into account systems for producing electricity (ORC cycle, hot air engines, thermoelectric conversion), or cold generation (sorption refrigeration machine, Thermo-ejector refrigeration machine) or techniques for energy storage with PCM (Phase Change Material). The last chapter deals to the achievement of four study cases written in the form of sheet and aimed at assess the applicability of the processes previously considered, concerning the field of waste. (authors)

  8. Acoustic emission energy b-value for local damage evaluation in reinforced concrete structures subjected to seismic loadings

    Science.gov (United States)

    Sagasta, Francisco; Zitto, Miguel E.; Piotrkowski, Rosa; Benavent-Climent, Amadeo; Suarez, Elisabet; Gallego, Antolino

    2018-03-01

    A modification of the original b-value (Gutenberg-Richter parameter) is proposed to evaluate local damage of reinforced concrete structures subjected to dynamical loads via the acoustic emission (AE) method. The modification, shortly called energy b-value, is based on the use of the true energy of the AE signals instead of its peak amplitude, traditionally used for the calculation of b-value. The proposal is physically supported by the strong correlation between the plastic strain energy dissipated by the specimen and the true energy of the AE signals released during its deformation and cracking process, previously demonstrated by the authors in several publications. AE data analysis consisted in the use of guard sensors and the Continuous Wavelet Transform in order to separate primary and secondary emissions as much as possible according to particular frequency bands. The approach has been experimentally applied to the AE signals coming from a scaled reinforced concrete frame structure, which was subjected to sequential seismic loads of incremental acceleration peak by means of a 3 × 3 m2 shaking table. For this specimen two beam-column connections-one exterior and one interior-were instrumented with wide band low frequency sensors properly attached on the structure. Evolution of the energy b-value along the loading process accompanies the evolution of the severe damage at the critical regions of the structure (beam-column connections), thus making promising its use for structural health monitoring purposes.

  9. Balancing Power Absorption and Fatigue Loads in Irregular Waves for an Oscillating Surge Wave Energy Converter: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Tom, Nathan M.; Yu, Yi-Hsiang; Wright, Alan D.; Lawson, Michael

    2016-06-01

    The aim of this paper is to describe how to control the power-to-load ratio of a novel wave energy converter (WEC) in irregular waves. The novel WEC that is being developed at the National Renewable Energy Laboratory combines an oscillating surge wave energy converter (OSWEC) with control surfaces as part of the structure; however, this work only considers one fixed geometric configuration. This work extends the optimal control problem so as to not solely maximize the time-averaged power, but to also consider the power-take-off (PTO) torque and foundation forces that arise because of WEC motion. The objective function of the controller will include competing terms that force the controller to balance power capture with structural loading. Separate penalty weights were placed on the surge-foundation force and PTO torque magnitude, which allows the controller to be tuned to emphasize either power absorption or load shedding. Results of this study found that, with proper selection of penalty weights, gains in time-averaged power would exceed the gains in structural loading while minimizing the reactive power requirement.

  10. 1993 Pacific Northwest Loads and Resources Study, Technical Appendix: Volume 2, Book 1, Energy.

    Energy Technology Data Exchange (ETDEWEB)

    United States. Bonneville Power Administration.

    1993-12-01

    The 1993 Pacific Northwest Loads and Resources Study establishes the Bonneville Power Administration`s (BPA) planning basis for supplying electricity to BPA customers. The Loads and Resources Study is presented in three documents: (1) this technical appendix detailing loads and resources for each major Pacific and Northwest generating utility, (2) a summary of Federal system and Pacific Northwest region loads and resources, and (3) a technical appendix detailing forecasted Pacific Northwest economic trends and loads. This analysis updates the 1992 Pacific Northwest Loads and Resources Study Technical Appendix published in December 1992. This technical appendix provides utility-specific information that BPA uses in its long-range planning. It incorporates the following for each utility (1) Electrical demand firm loads; (2) Generating resources; and (3) Contracts both inside and outside the region. This document should be used in combination with the 1993 Pacific Northwest Loads and Resources Study, published in December 1993, because much of the information in that document is not duplicated here.

  11. Energy balance of lactating primiparous sows as affected by feeding level and dietary energy source

    OpenAIRE

    Brand, van den, H.; Heetkamp, M.J.W.; Soede, N.M.; Schrama, J.W.; Kemp, B.

    2000-01-01

    The effects of feeding level and major dietary energy source used during lactation on sow milk composition, piglet body composition, and energy balance of sows were determined. During a 21-d lactation, 48 primiparous sows were fed either a Fat-rich (134.9 g/kg fat; 196.8 g/kg carbohydrate) or a Starch-rich (33.2 g/kg fat; 380.9 g/kg carbohydrate) diet at either a High (44 MJ NE/d; 1,050 g protein/d) or a Low (33 MJ NE/d; 790 g protein/d) feeding level. Within each feeding level, the two diets...

  12. The pizzicato knee-joint energy harvester: characterization with biomechanical data and the effect of backpack load

    International Nuclear Information System (INIS)

    Pozzi, Michele; Zhu, Meiling; Aung, Min S H; Goulermas, John Y; Jones, Richard K

    2012-01-01

    The reduced power requirements of miniaturized electronics offer the opportunity to create devices which rely on energy harvesters for their power supply. In the case of wearable devices, human-based piezoelectric energy harvesting is particularly difficult due to the mismatch between the low frequency of human activities and the high-frequency requirements of piezoelectric transducers. We propose a piezoelectric energy harvester, to be worn on the knee-joint, that relies on the plucking technique to achieve frequency up-conversion. During a plucking action, a piezoelectric bimorph is deflected by a plectrum; when released due to loss of contact, the bimorph is free to vibrate at its resonant frequency, generating electrical energy with the highest efficiency. A prototype, featuring four PZT-5H bimorphs, was built and is here studied in a knee simulator which reproduces the gait of a human subject. Biomechanical data were collected with a marker-based motion capture system while the subject was carrying a selection of backpack loads. The paper focuses on the energy generation of the harvester and how this is affected by the backpack load. By altering the gait, the backpack load has a measurable effect on performance: at the highest load of 24 kg, a minor reduction in energy generation (7%) was observed and the output power is reduced by 10%. Both are so moderate to be practically unimportant. The average power output of the prototype is 2.06 ± 0.3 mW, which can increase significantly with further optimization. (paper)

  13. CREEP BEHAVIOR OF BORATE-TREATED STRANDBOARD: EFFECT OF ZINC BORATE RETENTION, WOOD SPECIES, AND LOAD LEVEL

    OpenAIRE

    Wu,Qinglin; Lee,Ong N; Cai,Zhiyong; Zhou,Dingguo

    2009-01-01

    Creep performance of zinc borate-treated strandboard from southern pine (Pinus taeda L.) and red oak (Quercus falcata) was investigated at 25(0)C temperature and 65% relative humidity. It was shown that the borate treatment had some significant effect on creep deflection of the test panels, and the effect varied with wood species. There was no significant effect of creep loading on residual bending properties of treated strandboard under the stress levels used. The four element spring-dashpot...

  14. Technical note: optimization for improved tube-loading efficiency in the dual-energy computed tomography coupled with balanced filter method.

    Science.gov (United States)

    Saito, Masatoshi

    2010-08-01

    This article describes the spectral optimization of dual-energy computed tomography using balanced filters (bf-DECT) to reduce the tube loadings and dose by dedicating to the acquisition of electron density information, which is essential for treatment planning in radiotherapy. For the spectral optimization of bf-DECT, the author calculated the beam-hardening error and air kerma required to achieve a desired noise level in an electron density image of a 50-cm-diameter cylindrical water phantom. The calculation enables the selection of beam parameters such as tube voltage, balanced filter material, and its thickness. The optimal combination of tube voltages was 80 kV/140 kV in conjunction with Tb/Hf and Bi/Mo filter pairs; this combination agrees with that obtained in a previous study [M. Saito, "Spectral optimization for measuring electron density by the dual-energy computed tomography coupled with balanced filter method," Med. Phys. 36, 3631-3642 (2009)], although the thicknesses of the filters that yielded a minimum tube output were slightly different from those obtained in the previous study. The resultant tube loading of a low-energy scan of the present bf-DECT significantly decreased from 57.5 to 4.5 times that of a high-energy scan for conventional DECT. Furthermore, the air kerma of bf-DECT could be reduced to less than that of conventional DECT, while obtaining the same figure of merit for the measurement of electron density and effective atomic number. The tube-loading and dose efficiencies of bf-DECT were considerably improved by sacrificing the quality of the noise level in the images of effective atomic number.

  15. Multi-bunch energy spread induced by beam loading in standing wave structure

    International Nuclear Information System (INIS)

    Ferrario, M.; Tazzioli, F.

    1995-04-01

    The interaction of a relativistic beam with the modes of the TM 010 pass-band of a multicell cavity does not cause any problem: although all the modes are excited by the RF (radiofrequency) generator, resulting in different cell excitations during the cavity filling and the beam pulse, the net accelerating field exhibits negligible fluctuations from bunch to bunch. However, when the beam is not fully relativistic, this is no more true. The phase slippage occurring in the first cells, between the non relativistic beam and the lower pass-band modes, produces an effective enhancement of the shunt impedances, which is usually negligible for a relativistic beam in a well tuned cavity. Moreover, the voltage jumps (amplitude and phase) occurring at each bunch passage, as well as the beam detuning caused by the off-crest bunches, vary from cell to cell. These effects enhance dramatically the fluctuation of the accelerating voltage, with a dominant beating provided by the pass-band mode nearest to the pi-mode. The induced beam energy spread has been estimated by the help of two distinct codes, developed at Frascati (Italy) and (Saclay), with results in good agreement. While an interaction integral is computed at each bunch passage, the cavity refilling is calculated by solving coupled differential equations of the modes of the pass-band, driven by a generator linked to one end-cell. It is shown also that the intermode coupling arises from the external Q of the drive end-cell, and not from the wall losses. For illustration, the authors applied the method to the beam-loading problem in the SC capture cavity of the low charge injector of the TESLA test facility installed at DESY

  16. CASTOR registered HAW28M - a high heat load cask for transport and storage of vitrified high level waste containers

    International Nuclear Information System (INIS)

    Vossnacke, A.; Klein, K.; Kuehne, B.

    2004-01-01

    Within the German return programme for vitrified high level waste (HLW) from reprocessing at COGEMA and BNFL up to now 39 casks loaded with 28 containers each were transported back to Germany and are stored in the Interim Storage Facility Gorleben (TBL-G) for up to 40 years. For transport and storage in all but one case the GNB casks CASTOR registered HAW 20/28 CG have been used. This cask type is designed to accommodate 20 or 28 HLW containers with a total thermal power of 45 kW maximum. In the near future, among the high level waste, which has to be returned to Germany, there will be an increasing number of containers of which the heat capacity and radioactive inventory will exceed the technical limits of the CASTOR registered HAW 20/28 CG. Therefore GNB has started the development of a new cask generation, named CASTOR registered HAW28M, meeting these future requirements. The CASTOR registered HAW28M is especially developed for the transport of vitrified residues from France and Great Britain to Germany. It complies with the international regulations for type B packages according to IAEA (International Atomic Energy Agency). It is thus guaranteed that even in case of any accident the cask body and the lid system remain functional and the safe confinement of the radioactive contents remains intact during transport. The CASTOR registered HAW28M fulfills not only the requirements for transport but also the acceptance criteria of interim storage: radiation shielding, heat dissipation, safe confinement under both normal and hypothetical accident conditions. Storage buildings such as the TBL-G simply support the safety functions of the cask. The challenge for the development results from higher requirements of the technical specification, particularly related to fuel which is reprocessed. As a consequence of the reprocessing of fuel with increased enrichment and burn up, higher heat capacity and sophisticated shielding measures have to be considered. For the CASTOR

  17. The influence of the training loads of different on the nervousness level of the young sportsmen aged 13-16.

    Directory of Open Access Journals (Sweden)

    Khoroshukha M.F.

    2011-07-01

    Full Text Available The dynamics, structure and the indexes of the level of the teenagers' personal nervousness are considered. The teenagers are specialized in the following sporting activities: light athletics, skiing, cycling, swimming, boxing and free style fighting. 123 young sportsmen and 30 secondary school pupils, who don't go in for sports, aged 13-16 took part in the experiment. The comparative analysis nervousness level of the two groups was conducted: the first group - the speedy and powerful sporting activities and the second - the sporting activities concerning endurance. The fact of the specific influence of the loads of different directions on displaying the nervousness by young sportsmen was established.

  18. FORECASTING OF DURABILITY OF ASPHALT PAVEMENT ON THE BASIS OF LEVELS OF THEIR VIBRATION LOADING

    Directory of Open Access Journals (Sweden)

    V. A. Osinovskaya

    2015-01-01

    Full Text Available The problem of low durability of flexible pavement is one of the most important problems of road economy. For example, the actual service life of asphalt pavement in Russia about 3 … 5 years. The bad condition of highways is an obstacle for the development of the national economy and leads to a significant annual economic losses.At present, this problem has no exact solution. Even at the seeming good road conditions of Europe and America the problem of low durability is no less important in these countries. And this problem becomes more and more actual every year.Our scientific researches allowed to make a hypothesis that the projected of pavements are not have the necessary durability yet not of a stage of designing because in strength calculations did not take into account the vibration of road constructions.Very actual the vibration loading becomes today as is now significantly changed the nature of loading of pavements. As a result the deflections of a pavements are reduced, but the increased vibration of pavements accelerated processes of destruction and significantly reduced durability.The theory of vibration destruction developed by the author allows to adjust the vibration, to form the vibration resistance pavements, and also to forecast a residual life of pavements that will more effectively develop repair actions.

  19. AWARENESS AND COGNITIVE LOAD LEVELS OF TEACHER CANDIDATES TOWARDS STUDENT PRODUCTS MADE BY DIGITAL STORYTELLING

    Directory of Open Access Journals (Sweden)

    Figen KILIC

    2014-07-01

    Full Text Available The purpose of this research is to assess the student products created by digital storytelling, and to determine the awareness towards learning the topic and the cognitive loads of students during the process. Research was performed with a total of 52 teacher candidates attending 2nd class at “Classroom Teacher” department of Mersin University Faculty of Education in 2012-2013 education years. General scanning model was used to determine the cognitive loads and awareness of student products, created by teacher candidates through digital storytelling, for learning the topic. As a result of the Research, we reached the conclusion that the awareness related to basic concepts and program created by digital storytelling increased, and there was not a cognitive overload. Also, students’ opinions were taken on the process and according to acquired data, it was concluded that the students were pleased with the process, their awareness increased, and they made plans to improve what they learned and use them in the future. In line with acquired findings, it was suggested that experimental studies should be made on this topic. -

  20. Different Predictive Control Strategies for Active Load Management in Distributed Power Systems with High Penetration of Renewable Energy Sources

    DEFF Research Database (Denmark)

    Zong, Yi; Bindner, Henrik W.; Gehrke, Oliver

    2013-01-01

    In order to achieve a Danish energy supply based on 100% renewable energy from combinations of wind, biomass, wave and solar power in 2050 and to cover 50% of the Danish electricity consumption by wind power in 2020, it requires more renewable energy in buildings and industries (e.g. cold stores......, greenhouses, etc.), and to coordinate the management of large numbers of distributed energy resources with the smart grid solution. This paper presents different predictive control (Genetic Algorithm-based and Model Predictive Control-based) strategies that schedule controlled loads in the industrial...... and residential sectors, based on dynamic power price and weather forecast, considering users’ comfort settings to meet an optimization objective, such as maximum profit or minimum energy consumption. Some field tests were carried out on a facility for intelligent, active and distributed power systems, which...

  1. Power loss and energy density of the asymmetric ultracapacitor loaded with molybdenum doped manganese oxide

    International Nuclear Information System (INIS)

    Wang, Yue-Sheng; Tsai, Dah-Shyang; Chung, Wen-Hung; Syu, Yong-Sin; Huang, Ying-Sheng

    2012-01-01

    Highlights: ► Mo-doping (15 mol%) enhances capacitance and diminishes oxide resistance. ► Influences of Mo-doped MnO 2 are analyzed at the level of capacitor power and energy. ► Polarization loss of the asymmetric capacitor is more than that of the symmetric one. ► Pseudocapacitance benefit on energy is evaluated with power and current densities. - Abstract: Ultracapacitors of asymmetric configuration have been prepared with activated carbon (AC) and undoped or Mo-doped manganese oxide (MnO 2 ) in 1.0 M Na 2 SO 4 electrolyte. Phase analysis shows the AC powder, 1–15 μm in size, contains both disordered and graphitic structures, and the undoped and Mo-doped oxide powder, 0.05–0.20 μm in particle size, mainly involves amorphous MnO 2 and MoO 2 . CV results indicate the single electrode of AC plus 10 wt% Mo-doped MnO 2 (A9O M 1) is superior to the electrode with undoped MnO 2 or high content of doped MnO 2 , exhibiting features of double layer capacitance at high scan rate and pseudocapacitance characteristics at low scan rate. When assembled with a negative electrode of AC, the capacitor of positive A9O M 1 electrode demonstrates the least power loss among three asymmetric capacitors. This asymmetric capacitor also shows a higher capacitance than the symmetric AC capacitor when the current density is less than 8.0 A g −1 in 1.8 V potential window. But a higher electrode resistance of A9O M 1, in contrast with AC, compromises its capacitance plus. When the energy density of A9O M 1 asymmetric capacitor is compared with that of symmetric AC capacitor at the same power level, the capacitance benefit on energy density is restricted to current density ≤ 3.0 A g −1 .

  2. Increased Plasma Cell-Free DNA Level during HTNV Infection: Correlation with Disease Severity and Virus Load

    Directory of Open Access Journals (Sweden)

    Jing Yi

    2014-07-01

    Full Text Available Cell-free DNA (cf-DNA in blood represents a promising DNA damage response triggered by virus infection or trauma, tumor, etc. Hantavirus primarily causes two diseases: haemorrhagic fever with renal syndrome (HFRS and Hantavirus cardiopulmonary syndrome (HCPS, depending on different Hantavirus species. The aim of this study was to evaluate plasma cf-DNA levels in acute phase of HFRS, and to correlate plasma cf-DNA with disease severity and plasma Hanttan virus (HTNV load. We observed the appearance of cf-DNA in 166 plasma samples from 76 HFRS patients: the plasma cf-DNA levels peaked at the hypotensive stage of HFRS, and then decreased gradually. Until the diuretic stage, there was no significant difference in plasma cf-DNA level between patients and the healthy control. Exclusively in the febrile/hypotensive stage, the plasma cf-DNA levels of severe/critical patients were higher than those of the mild/moderate group. Moreover, the plasma cf-DNA value in the early stage of HFRS was correlated with HTNV load and disease severity. In most of the patients, plasma cf-DNA displayed a low-molecular weight appearance, corresponding to the size of apoptotic DNA. In conclusion, the plasma cf-DNA levels were dynamically elevated during HFRS, and correlated with disease severity, which suggests that plasma cf-DNA may be a potential biomarker for the pathogenesis and prognosis of HFRS.

  3. Innovations in Multi-Level Governance for Energy Efficiency

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2009-07-01

    Recent IEA analysis highlights member countries' significant progress with developing energy efficiency policy (International Energy Agency 2009). The 28 member countries of the IEA are engaged in promoting innovative financial instruments, energy efficiency strategies and action plans. They are designing policies to promote energy efficiency in buildings, the adoption of standby power, the phase out of inefficient lighting, proper tyre-inflation and related policies, and energy efficiency in utilities.

  4. Innovations in Multi-Level Governance for Energy Efficiency

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2009-07-01

    Recent IEA analysis highlights member countries' significant progress with developing energy efficiency policy (International Energy Agency 2009). The 28 member countries of the IEA are engaged in promoting innovative financial instruments, energy efficiency strategies and action plans. They are designing policies to promote energy efficiency in buildings, the adoption of standby power, the phase out of inefficient lighting, proper tyre-inflation and related policies, and energy efficiency in utilities.

  5. Static and Dynamic Stability Analysis of Distributed Energy Resources Components with Storage Devices and Loads for Smart Grids

    DEFF Research Database (Denmark)

    Mihet-Popa, Lucian; Groza, V.

    2011-01-01

    of the Smart Grids (SGs). A SG can operate interconnected to the main distribution grid or in islanded mode. This paper presents experimental tests for static and dynamic stability analysis carried out in a dedicated laboratory for research in distributed control and smart grid with a high share of renewable......The distributed energy resources (DER) contains several technologies, such as diesel engines, small wind turbines, photovoltaic inverters, etc. The control of DER components with storage devices and (controllable) loads, such as batteries, capacitors, dump loads, are central to the concept...... energy production. Moreover to point out, on a laboratory scale, the coupling between DR and storage and to effectively compensate wind fluctuations a number of tests have been done. In order to find out the parameters of various types of DER components for dynamic simulation models a number of tests...

  6. Energy utilization of light and heavy weaned piglets subjected to different dietary energy levels

    Directory of Open Access Journals (Sweden)

    Andréa Machado Leal Ribeiro

    Full Text Available ABSTRACT This study was conducted to evaluate the effects of dietary metabolisable energy (ME: 3.25, 3.40, 3.55, or 3.70 Mcal kg−1 and weaning weight (WW: light 4.0±0.7 kg, and heavy: 6.3±0.6 kg on productive response and energy utilization of weaned piglets. Sixty-four male piglets were housed in 32 metabolic cages (two animals per cage during the first 14 d postweaning. At day 15, only one animal per cage was kept until day 28. Body composition, energy, and nutrient deposition rates and energy utilization efficiency were measured through a comparative slaughter procedure. Piglets with light WW had a poorer feed conversion ratio and lower weight gain and feed intake when expressed per live weight. Increased ME led to greater daily fat deposition in the empty bodies (defined as weighted mean of the carcass + organs + blood, no intestinal content, while light WW piglets had a reduced protein deposition. Light WW piglets increased heat production with increased ME, but no effect was seen for the heavy WW piglets. By contrast, heavy WW piglets increased empty body gross energy as ME increased, while no influence was observed on light WW piglets. Increasing dietary energy levels did not contribute to the subsequent growth performance of piglets that were lighter at weaning. The lack of interaction between weaning weight and dietary ME content on growth performance does not support the hypothesis that light piglets at weaning do not exhibit compensatory growth because of limitations in energy intake.

  7. Exergy and Energy Analysis of Combustion of Blended Levels of Biodiesel, Ethanol and Diesel Fuel in a DI Diesel Engine

    International Nuclear Information System (INIS)

    Khoobbakht, Golmohammad; Akram, A.; Karimi, Mahmoud; Najafi, G.

    2016-01-01

    Highlights: • Exergy analysis showed that thermal efficiency of diesel engine was 36.61%. • Energy loss and work output rates were 71.36 kW and 41.22 kW, respectively. • Exergy efficiency increased with increasing engine load and speed. • Exergy efficiency increased with increasing biodiesel and bioethanol. • 0.17 L of biodiesel, 0.08 L of ethanol in 1 L of diesel at 1900 rpm and 94% load had maximum exergy efficiency. - Abstract: In this study, the first and second laws of thermodynamics are employed to analyze the energy and energy in a four-cylinder, direct injection diesel engine using blended levels of biodiesel and ethanol in diesel fuel. Also investigated the effect of operating factors of engine load and speed as well as blended levels of biodiesel and ethanol in diesel fuel on the exergy efficiency. The experiments were designed using a statistical tool known as Design of Experiments (DoE) based on central composite rotatable design (CCRD) of response surface methodology (RSM). The resultant quadratic models of the response surface methodology were helpful to predict the response parameter (exergy efficiency) further to identify the significant interactions between the input factors on the responses. The results depicted that the exergy efficiency decreased with increasing percent by volume biodiesel and ethanol fuel. The fuel blend of 0.17 L biodiesel and 0.08 L of ethanol added to 1 L of diesel (equivalent with D80B14E6) at 1900 rpm and 94% load was realized have the most exergy efficiency. The results of energy and exergy analyses showed that 43.09% of fuel exergy was destructed and the average thermal efficiency was approximately 36.61%, and the exergetic efficiency was approximately 33.81%.

  8. Balancing Power Absorption and Structural Loading for an Assymmetric Heave Wave-Energy Converter in Regular Waves: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Tom, Nathan M.; Madhi, Farshad; Yeung, Ronald W.

    2016-07-01

    The aim of this paper is to maximize the power-to-load ratio of the Berkeley Wedge: a one-degree-of-freedom, asymmetrical, energy-capturing, floating breakwater of high performance that is relatively free of viscosity effects. Linear hydrodynamic theory was used to calculate bounds on the expected time-averaged power (TAP) and corresponding surge restraining force, pitch restraining torque, and power take-off (PTO) control force when assuming that the heave motion of the wave energy converter remains sinusoidal. This particular device was documented to be an almost-perfect absorber if one-degree-of-freedom motion is maintained. The success of such or similar future wave energy converter technologies would require the development of control strategies that can adapt device performance to maximize energy generation in operational conditions while mitigating hydrodynamic loads in extreme waves to reduce the structural mass and overall cost. This paper formulates the optimal control problem to incorporate metrics that provide a measure of the surge restraining force, pitch restraining torque, and PTO control force. The optimizer must now handle an objective function with competing terms in an attempt to maximize power capture while minimizing structural and actuator loads. A penalty weight is placed on the surge restraining force, pitch restraining torque, and PTO actuation force, thereby allowing the control focus to be placed either on power absorption or load mitigation. Thus, in achieving these goals, a per-unit gain in TAP would not lead to a greater per-unit demand in structural strength, hence yielding a favorable benefit-to-cost ratio. Demonstrative results in the form of TAP, reactive TAP, and the amplitudes of the surge restraining force, pitch restraining torque, and PTO control force are shown for the Berkeley Wedge example.

  9. Study of a conceptual nuclear energy center at Green River, Utah. Power demand, load center assessment and transmission

    Energy Technology Data Exchange (ETDEWEB)

    Smith, D.R.; Thaik, A.; Pingel, P.

    1982-02-01

    This document constitutes a segment of a feasibility study investigating the ramification of constructing a nuclear energy center in an arid western region. In this phase of the study. The projected power demands and load center locations were reviewed and assessed. Alternative transmission systems were analysed and a conceptual transmission for bulk power transportation is proposed with potential line routes. Environmental impacts of the proposed transmission were also identified.

  10. Study of a conceptual nuclear energy center at Green River, Utah. Power demand, load center assessment and transmission

    International Nuclear Information System (INIS)

    Smith, D.R.; Thaik, A.; Pingel, P.

    1982-02-01

    This document constitutes a segment of a feasibility study investigating the ramification of constructing a nuclear energy center in an arid western region. In this phase of the study. The projected power demands and load center locations were reviewed and assessed. Alternative transmission systems were analysed and a conceptual transmission for bulk power transportation is proposed with potential line routes. Environmental impacts of the proposed transmission were also identified

  11. Dependence of Seebeck coefficient on a load resistance and energy conversion efficiency in a thermoelectric composite

    International Nuclear Information System (INIS)

    Yamashita, Osamu; Odahara, Hirotaka; Ochi, Takahiro; Satou, Kouji

    2007-01-01

    The thermo-emf ΔV and current ΔI generated by imposing the alternating temperature gradients (ATG) at a period of T and the steady temperature gradient (STG) on a thermoelectric (TE) composite were measured as a function of t, where t is the lapsed time and T was varied from 60 to or ∞ s. The STG and ATG were produced by imposing steadily and alternatively a source voltage V in the range from 1.0 to 4.0 V on two Peltier modules sandwiching a composite. ΔT, ΔV, ΔI and V P oscillate at a period T and their waveforms vary significantly with a change of T, where ΔV and V P are the voltage drops in a load resistance R L and in resistance R P of two modules. The resultant Seebeck coefficient |α| = |ΔV|/ΔT of a composite under the STG was found to be expressed as |α| = |α 0 |(1 - R comp /R T ), where R T is the total resistance of a circuit for measuring the output signals and R comp is the resistance of a composite. The effective generating power ΔW eff has a local maximum at T = 960 s for the p-type composite and at T = 480 s for the n-type one. The maximum energy conversion efficiency η of the p- and n-type composites under the ATG produced by imposing a voltage of 4.0 V at an optimum period were 0.22 and 0.23% at ΔT eff = 50 K, respectively, which are 42 and 43% higher than those at ΔT = 42 K under the STG. These maximum η for a TE composite sandwiched between two Peltier modules, were found to be expressed theoretically in terms of R P , R T , R L , α P and α, where α P and α are the resultant Seebeck coefficients of Peltier modules and a TE composite

  12. Association between increase in vertical ground reaction force loading rate and pain level in women with patellofemoral pain after a patellofemoral joint loading protocol.

    Science.gov (United States)

    Briani, Ronaldo Valdir; Pazzinatto, Marcella Ferraz; Waiteman, Marina Cabral; de Oliveira Silva, Danilo; de Azevedo, Fábio Mícolis

    2018-04-11

    The etiology of patellofemoral pain (PFP) is thought to be the result of increased patellofemoral joint (PFJ) load and aberrant lower extremity mechanics, including altered vertical ground reaction forces (VGRF). However, few studies have investigated the association between an increase in pain and VGRF loading rates in the context of PFP. Thus, this study aimed to investigate the immediate effects of PFJ loading on pain and VGRF loading rate, and to see if there is a link between modification of both pain and VGRF loading rate during stair negotiation. Thirty-four women with PFP underwent VGRF analysis during stair negotiation under two conditions: with (condition 2) and without (condition 1) being previously submitted to a PFJ loading protocol in order to or not to exacerbate their knee pain, respectively. The VGRF loading rates were significantly higher in condition 2 (Mean ± standard deviation (SD)=4.0±0.6N/s) compared to condition 1 (Mean±SD=3.6±0.5N/s) during stair ascent and during stair descent (Mean±SD: condition 1=6.3±1.1N/s; condition 2=7.0±1.4N/s). In addition, VGRF loading rates were higher during stair descent compared to stair ascent in both conditions. There were significant correlations between the increase in pain and VGRF loading rate during both tasks. There seemed to be an important relation between the increase in pain and VGRF loading rates in women with PFP. Based on these findings, interventions aimed at reducing VGRF loading rates are important in the context of PFP. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Marginal bone-level alterations of loaded zirconia and titanium dental implants: an experimental study in the dog mandible.

    Science.gov (United States)

    Thoma, Daniel S; Benic, Goran I; Muñoz, Fernando; Kohal, Ralf; Sanz Martin, Ignacio; Cantalapiedra, Antonio G; Hämmerle, Christoph H F; Jung, Ronald E

    2016-04-01

    The aim was to test whether or not the marginal bone-level alterations of loaded zirconia implants are similar to the bone-level alterations of a grade 4 titanium one-piece dental implant. In six dogs, all premolars and the first molars were extracted in the mandible. Four months later, three zirconia implants (BPI, VC, ZD) and a control titanium one-piece (STM) implant were randomly placed in each hemimandible and left for transmucosal healing (baseline). Six months later, CAD/CAM crowns were cemented. Sacrifice was scheduled at 6-month postloading. Digital X-rays were taken at implant placement, crowns insertion, and sacrifice. Marginal bone-level alterations were calculated, and intra- and intergroup comparisons performed adjusted by confounding factors. Implants were successfully placed. Until crown insertion, two implants were fractured (one VC, one ZD). At sacrifice, 5 more implants were (partly) fractured (one BPI, four ZD), and one lost osseointegration (VC). No decementation of crowns occurred. All implant systems demonstrated a statistically significant (except VC) loss of marginal bone between baseline and crown insertion ranging from 0.29 mm (VC; P = 0.116) to 0.80 mm (ZD; P = 0.013). The estimated marginal bone loss between baseline and 6 months of loading ranged between 0.19 mm (BPI) and 1.11 mm (VC), being statistically significant for STM and VC only (P implants and control implants (STM vs. BPI P = 0.007; vs. VC P = 0.001; vs. ZD P = 0.011). Zirconia implants were more prone to fracture prior to and after loading with implant-supported crowns compared to titanium implants. Individual differences and variability in the extent of the bone-level changes during the 12-month study period were found between the different implant types and materials. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Energy expended and knee joint load accumulated when walking, running, or standing for the same amount of time.

    Science.gov (United States)

    Miller, Ross H; Edwards, W Brent; Deluzio, Kevin J

    2015-01-01

    Evidence suggests prolonged bouts of sitting are unhealthy, and some public health messages have recently recommended replacing sitting with more standing. However, the relative benefits of replacing sitting with standing compared to locomotion are not known. Specifically, the biomechanical consequences of standing compared to other sitting-alternatives like walking and running are not well known and are usually not considered in studies on sitting. We compared the total knee joint load accumulated (TKJLA) and the total energy expended (TEE) when performing either walking, running, or standing for a common exercise bout duration (30 min). Walking and running both (unsurprisingly) had much more TEE than standing (+300% and +1100%, respectively). TKJLA was similar between walking and standing and 74% greater in running. The results suggest that standing is a poor replacement for walking and running if one wishes to increases energy expenditure, and may be particularly questionable for use in individuals at-risk for knee osteoarthritis due to its surprisingly high TKJLA (just as high as walking, 56% of the load in running) and the type of loading (continuous compression) it places on cartilage. However, standing has health benefits as an "inactivity interrupter" that extend beyond its direct energy expenditure. We suggest that future studies on standing as an inactivity intervention consider the potential biomechanical consequences of standing more often throughout the day, particularly in the case of prolonged bouts of standing. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. The Effect of Electric Load Profiles on the Performance of Off-Grid Residential Hybrid Renewable Energy Systems

    Directory of Open Access Journals (Sweden)

    Stephen Treado

    2015-10-01

    Full Text Available This paper investigates the energy performance of off-grid residential hybrid renewable electric power systems, particularly the effect of electric load profiles on the ability to harvest available solar energy and avoid the consumption of auxiliary energy in the form of propane. The concepts are illustrated by an analysis of the energy performance of electric and propane-fired refrigerators. Off-grid electric power systems frequently incorporate a renewable source, such as wind or solar photovoltaic (PV, with a back-up power provided by a propane fueled motor/generator. Among other design decisions, residential consumers face the choice of employing an electric refrigerator with a conventional vapor compression refrigeration system, or a fuel-fired refrigerator operating as an absorption refrigeration system. One interesting question is whether it is more advantageous from an energy perspective to use electricity to run the refrigerator, which might be provided by some combination of the PV and propane motor/generator, thereby taking advantage of the relatively higher electric refrigerator Coefficient of Performance (COP and free solar energy but having to accept a low electrical conversion efficiency of the motor/generator, or use thermal energy from the combustion of propane to produce the refrigeration effect via an absorption system, albeit with a much lower COP. The analysis is complicated by the fact that most off-grid renewable electrical power systems utilize a battery bank to provide electrical power when it is not available from the wind turbine or PV system, so the state of charge of the battery bank will have a noticeable impact on what energy source is available at any moment in time. Daily electric load profiles combined with variable solar energy input determine the state of charge of the battery bank, with the degree of synchronization between the two being a critical factor in determining performance. The annual energy usage

  16. Performance of Loaded Thermal Storage Unit with a Commercial Phase Change Materials based on Energy and Exergy Analysis

    Directory of Open Access Journals (Sweden)

    Abdullah Nasrallh Olimat

    2017-11-01

    Article History: Received July 6th 2017; Received in revised form September 15th 2017; Accepted 25th Sept 2017; Available online How to Cite This Article: Olimat, A.N., Awad, A.S., Al-Gathain, F.M., and Shaban, N.A.. (2017 Performance of Loaded Thermal Storage Unit With A Commercial Phase Change Materials Based on Energy and Exergy Analysis. International Journal of Renewable Energy Develeopment, 6(3,283-290. https://doi.org/10.14710/ijred.6.3.283-290

  17. Enzymatic versus Inorganic Oxygen Reduction Catalysts: Comparison of the Energy Levels in a Free-Energy Scheme

    DEFF Research Database (Denmark)

    Kjærgaard, Christian Hauge; Rossmeisl, Jan; Nørskov, Jens Kehlet

    2010-01-01

    In this paper, we present a method to directly compare the energy levels of intermediates in enzymatic and inorganic oxygen reduction catalysts. We initially describe how the energy levels of a Pt(111) catalyst, operating at pH = 0, are obtained. By a simple procedure, we then convert the energy...... levels of cytochrome c oxidase (CcO) models obtained at physiological pH = 7 to the energy levels at pH = 0, which allows for comparison. Furthermore, we illustrate how different bias voltages will affect the free-energy landscapes of the catalysts. This allows us to determine the so-called theoretical...

  18. Economic energy distribution and consumption in a microgrid Part1: Cell level controller

    DEFF Research Database (Denmark)

    Tahersima, Fatemeh; Andersen, Palle; Madsen, Per Printz

    2013-01-01

    We have investigated energy management of a small scale electrical microgrid comprised of local renewable generation, consumption and storage units. The microgrid has the possibility of connection to the electricity grid as well to compensate for energy deficit. The objective is to fulfill...... microgrid's energy demands from the local electricity producers as much as possible. The other objective is to manage the consumption such that consumption costs are minimum for all households. To fulfill the objectives, as the first step of designing a hierarchical controller, we focused on designing...... an energy and cost minimizing controller for one building. To this aim, a model predictive controller is formulated to schedule the building's energy consumption using potential load flexibility. Simulation results show the economically optimal energy consumption of one building based on the defined load...

  19. Artificial bee colony algorithm for economic load dispatch with wind power energy

    Directory of Open Access Journals (Sweden)

    Safari Amin

    2016-01-01

    Full Text Available This paper presents an efficient Artificial Bee Colony (ABC algorithm for solving large scale economic load dispatch (ELD problems in power networks. To realize the ELD, the valve-point loading effect, system load demand, power losses, ramp rate limits and prohibited operation zones are considered here. Simulations were performed on four different power systems with 3, 6, 15 and 40 generating units and the results are compared with two forms of power systems, one power system is with a wind power generator and other power system is without a wind power generator. The results of this study reveal that the proposed approach is able to find appreciable ELD solutions than those of previous algorithms.

  20. Automatic optimization of core loading patterns to maximize cycle energy production within operational constraints

    International Nuclear Information System (INIS)

    Hobson, G.H.; Turinsky, P.J.

    1986-01-01

    Computational capability has been developed to automatically determine the core loading pattern which minimizes fuel cycle costs for a pressurized water reactor. Equating fuel cycle cost minimization with core reactivity maximization, the objective is to determine the loading pattern which maximizes core reactivity at end-of-cycle while satisfying the power peaking constraint throughout the cycle and region average discharge burnup limit. The method utilizes a two-dimensional, coarse mesh, finite difference scheme to evaluate core reactivity and fluxes for an initial reference loading pattern as a function of cycle burnup. First order perturbation theory is applied to determine the effects of assembly shuffling on reactivity, power distribution, and end-of-cycle burnup

  1. Real-Time Monitoring of Low-Level Mixed-Waste Loading during Polyethylene Microencapsulation using Transient Infrared Spectroscopy

    International Nuclear Information System (INIS)

    Jones, Roger W.; Kalb, Paul D.; McClelland, John F.; Ochiai, Shukichi

    1999-01-01

    In polyethylene microencapsulation, low-level mixed waste (LLMW) is homogenized with molten polyethylene and extruded into containers, resulting in a lighter, lower-volume waste form than cementation and grout methods produce. Additionally, the polyethylene-based waste form solidifies by cooling, with no risk of the waste interfering with cure, as may occur with cementation and grout processes. We have demonstrated real-time monitoring of the polyethylene encapsulation process stream using a noncontact device based on transient infrared spectroscopy (TIRS). TIRS can acquire mid-infrared spectra from solid or viscous liquid process streams, such as the molten, waste-loaded polyethylene stream that exits the microencapsulation extruder. The waste loading in the stream was determined from the TIRS spectra using partial least squares techniques. The monitor has been demonstrated during the polyethylene microencapsulation of nitrate-salt LLMW and its surrogate, molten salt oxidation LLMW and its surrogate, and flyash. The monitor typically achieved a standard error of prediction for the waste loading of about 1% by weight with an analysis time under 1 minute

  2. Sensing Properties of Pd-Loaded Co3O4 Film for a ppb-Level NO Gas Sensor

    Directory of Open Access Journals (Sweden)

    Takafumi Akamatsu

    2015-04-01

    Full Text Available We prepared 0.1 wt%–30 wt% Pd-loaded Co3O4 by a colloidal mixing method and investigated the sensing properties of a Pd-loaded Co3O4 sensor element, such as the sensor response, 90% response time, 90% recovery time, and signal-to-noise (S/N ratio, toward low nitric oxide (NO gas levels in the range from 50 to 200 parts per billion. The structural properties of the Pd-loaded Co3O4 powder were investigated using X-ray diffraction analysis and transmission electron microscopy. Pd in the powder existed as PdO. The sensor elements with 0.1 wt%–10 wt% Pd content have higher sensor properties than those without any Pd content. The response of the sensor element with a 30 wt% Pd content decreased markedly because of the aggregation and poor dispersibility of the PdO particles. High sensor response and S/N ratio toward the NO gas were achieved when a sensor element with 10 wt% Pd content was used.

  3. Impact of energy policy instruments on the estimated level of underlying energy efficiency in the EU residential sector

    International Nuclear Information System (INIS)

    Filippini, Massimo; Hunt, Lester C.; Zorić, Jelena

    2014-01-01

    The promotion of energy efficiency is seen as one of the top priorities of EU energy policy (EC, 2010). In order to design and implement effective energy policy instruments, it is necessary to have information on energy demand price and income elasticities in addition to sound indicators of energy efficiency. This research combines the approaches taken in energy demand modelling and frontier analysis in order to econometrically estimate the level of energy efficiency for the residential sector in the EU-27 member states for the period 1996 to 2009. The estimates for the energy efficiency confirm that the EU residential sector indeed holds a relatively high potential for energy savings from reduced inefficiency. Therefore, despite the common objective to decrease ‘wasteful’ energy consumption, considerable variation in energy efficiency between the EU member states is established. Furthermore, an attempt is made to evaluate the impact of energy-efficiency measures undertaken in the EU residential sector by introducing an additional set of variables into the model and the results suggest that financial incentives and energy performance standards play an important role in promoting energy efficiency improvements, whereas informative measures do not have a significant impact. - Highlights: • The level of energy efficiency of the EU residential sector is estimated. • Considerable potential for energy savings from reduced inefficiency is established. • The impact of introduced energy-efficiency policy measures is also evaluated. • Financial incentives are found to promote energy efficiency improvements. • Energy performance standards also play an important role

  4. Optimizing the Operation of Windfarms, Energy Storage and Flexible Loads in Modern Power Systems and Deregulated Electricity Markets

    Science.gov (United States)

    Dar, Zamiyad

    most turbines is quite close to 1/3 and yaw angle acts as the dominant optimization variable. In the next part of this dissertation, a system comprising of a windfarm and energy storage operating in real-time electricity markets is studied. An Energy-balancing Threshold Price (ETP) policy is proposed to maximize the revenue of a windfarm with on-site storage. We propose and analyze a scheme for a windfarm to store or sell energy based on a threshold price. The threshold price is calculated based on long-term distributions of the electricity price and wind power generation processes, and is chosen so as to balance the energy flows in and out of the storage-equipped windfarm. It is also shown mathematically that the proposed policy is optimal in terms of the long-term revenue generated. Comparing it with the optimal policy that has knowledge of the future, we observe that the revenue obtained by the proposed ETP policy is approximately 90% of the maximum attainable revenue at a storage capacity of 10-15 times the power rating of the windfarm. The intermittent nature of wind power is a hindrance to the efficient participation of windfarms in the day-ahead and forward electricity markets. In this regard, a flexible forward contract is proposed in this dissertation which allows the windfarms to enter into a forward contract with flexible load with an option to deviate from the contracted amount of power. Using such a flexible contract would allow the windfarms to supply more or less than the contracted amount of power in case of unexpected wind conditions or real-time prices. We also propose models for forecasting wind power and real-time electricity prices. The comparison between the proposed contracting framework and a simple fixed contract (currently existing in the market) for different levels of flexibility and load shows that there is a net gain in windfarm revenues, if the transaction price of the two contracts are set equal. Lastly, we present and analyze

  5. Determination of minimum height and lateral design load for MASH test level 4 bridge rails.

    Science.gov (United States)

    2011-12-01

    The Manual for Assessing Safety Hardware (MASH) prescribes higher design vehicle impact speed and mass for test level 4 barriers compared to its predecessor National Cooperative Highway Research Program (NCHRP) Report 350. This has resulted in a 56 p...

  6. Energy-level statistics and time relaxation in quantum systems

    International Nuclear Information System (INIS)

    Gruver, J.L.; Cerdeira, H.A.; Aliaga, J.; Mello, P.A.; Proto, A.N.

    1997-05-01

    We study a quantum-mechanical system, prepared, at t = 0, in a model state, that subsequently decays into a sea of other states whose energy levels form a discrete spectrum with given statistical properties. An important quantity is the survival probability P(t), defined as the probability, at time t, to find the system in the original model state. Our main purpose is to analyze the influence of the discreteness and statistical properties of the spectrum on the behavior of P(t). Since P(t) itself is a statistical quantity, we restrict our attention to its ensemble average , which is calculated analytically using random-matrix techniques, within certain approximations discussed in the text. We find, for , an exponential decay, followed by a revival, governed by the two-point structure of the statistical spectrum, thus giving a nonzero asymptotic value for large t's. The analytic result compares well with a number of computer simulations, over a time range discussed in the text. (author). 17 refs, 1 fig

  7. Higher order corrections to energy levels of muonic atoms

    International Nuclear Information System (INIS)

    Rinker, G.A. Jr.; Steffen, R.M.

    1975-08-01

    In order to facilitate the analysis of muonic x-ray spectra, the results of numerical computations of all higher order quantum electrodynamical corrections to the energy levels of muonic atoms are presented in tabular and graphical form. These corrections include the vacuum polarization corrections caused by emission and reabsorption of virtual electron pairs to all orders, including ''double-bubble'' and ''cracked-egg'' diagrams. An estimate of the Delbruecke scattering-type correction is presented. The Lamb-shift (second- and fourth-order vertex) corrections have been calculated including the correction for the anomalous magnetic moment of the muon. The relativistic nuclear motion (or recoil) correction as well as the correction caused by the screening of the atomic electrons is presented in graphs. For the sake of completeness a graph of the nuclear polarization as computed on the basis of Chen's approach has been included. All calculations were made with a two-parameter Fermi distribution of the nuclear charge density. 7 figures, 23 references

  8. Comparison of creep behavior under varying load/temperature conditions between Hastelloy XR alloys with different boron content levels

    International Nuclear Information System (INIS)

    Tsuji, Hirokazu; Nakajima, Hajime; Shindo, Masami; Tanabe, Tatsuhiko; Nakasone, Yuji.

    1996-01-01

    In the design of the high-temperature components, it is often required to predict the creep rupture life under the conditions in which the stress and/or temperature may vary by using the data obtained with the constant load and temperature creep rupture tests. Some conventional creep damage rules have been proposed to meet the above-mentioned requirement. Currently only limited data are available on the behavior of Hastelloy XR, which is a developed alloy as the structural material for high-temperature components of the High-Temperature Engineering Test Reactor (HTTR), under varying stress and/or temperature creep conditions. Hence a series of constant load and temperature creep rupture tests as well as varying load and temperature creep rupture tests was carried out on two kinds of Hastelloy XR alloys whose boron content levels are different, i.e., below 10 and 60 mass ppm. The life fraction rule completely fails in the prediction of the creep rupture life of Hastelloy XR with 60 mass ppm boron under varying load and temperature conditions though the rule shows good applicability for Hastelloy XR with below 10 mass ppm boron. The change of boron content level of the material during the tests is the most probable source of impairing the applicability of the life fraction rule to Hastelloy XR whose boron content level is 60 mass ppm. The modified life fraction rule has been proposed based on the dependence of the creep rupture strength on the boron content level of the alloy. The modified rule successfully predicts the creep rupture life under the two stage creep test conditions from 1000 to 900degC. The trend observed in the two stage creep tests from 900 to 1000degC can be qualitatively explained by the mechanism that the oxide film which is formed during the prior exposure to 900degC plays the role of the protective barrier against the boron dissipation into the environment. (J.P.N.)

  9. Optimal Planning Method of On-load Capacity Regulating Distribution Transformers in Urban Distribution Networks after Electric Energy Replacement Considering Uncertainties

    Directory of Open Access Journals (Sweden)

    Yu Su

    2018-06-01

    Full Text Available Electric energy replacement is the umbrella term for the use of electric energy to replace oil (e.g., electric automobiles, coal (e.g., electric heating, and gas (e.g., electric cooking appliances, which increases the electrical load peak, causing greater valley/peak differences. On-load capacity regulating distribution transformers have been used to deal with loads with great valley/peak differences, so reasonably replacing conventional distribution transformers with on-load capacity regulating distribution transformers can effectively cope with load changes after electric energy replacement and reduce the no-load losses of distribution transformers. Before planning for on-load capacity regulating distribution transformers, the nodal effective load considering uncertainties within the life cycle after electric energy replacement was obtained by a Monte Carlo method. Then, according to the loss relation between on-load capacity regulating distribution transformers and conventional distribution transformers, three characteristic indexes of annual continuous apparent power curve and replacement criteria for on-load capacity regulating distribution transformers were put forward in this paper, and a set of distribution transformer replaceable points was obtained. Next, based on cost benefit analysis, a planning model of on-load capacity regulating distribution transformers which consists of investment profitability index within the life cycle, investment cost recouping index and capacity regulating cost index was put forward. The branch and bound method was used to solve the planning model within replaceable point set to obtain upgrading and reconstruction scheme of distribution transformers under a certain investment. Finally, planning analysis of on-load capacity regulating distribution transformers was carried out for electric energy replacement points in one urban distribution network under three scenes: certain load, uncertain load and nodal

  10. Experimental study on the structural and mooring loads of the WEPTOS Wave Energy Converter

    DEFF Research Database (Denmark)

    Pecher, Arthur Francois Serge; Kofoed, Jens Peter

    This report presents the results of an experimental study that was performed on small scale model that was a replication of the full-scale Weptos WEC intended for DanWEC. During these tests, after optimising the mooring solution, various loads were measured that occur in the structure and mooring...

  11. Load ratio determines the ammonia recovery and energy input of an electrochemical system

    NARCIS (Netherlands)

    Rodríguez Arredondo, Mariana; Kuntke, Philipp; Heijne, Ter Annemiek; Hamelers, Hubertus V.M.; Buisman, Cees J.N.

    2017-01-01

    Complete removal and recovery of total ammonia nitrogen (TAN) from wastewaters in (bio)electrochemical systems has proven to be a challenge. The system performance depends on several factors, such as current density, TAN loading rate and pH. The interdependence among these factors is not well

  12. Load Balancing Integrated Least Slack Time-Based Appliance Scheduling for Smart Home Energy Management

    OpenAIRE

    Bhagya Nathali Silva; Murad Khan; Kijun Han

    2018-01-01

    The emergence of smart devices and smart appliances has highly favored the realization of the smart home concept. Modern smart home systems handle a wide range of user requirements. Energy management and energy conservation are in the spotlight when deploying sophisticated smart homes. However, the performance of energy management systems is highly influenced by user behaviors and adopted energy management approaches. Appliance scheduling is widely accepted as an effective mechanism to manage...

  13. Clean Energy Policy Analyses: Analysis of the Status and Impact of Clean Energy Policies at the Local Level

    Energy Technology Data Exchange (ETDEWEB)

    Busche, S.

    2010-12-01

    This report takes a broad look at the status of local clean energy policies in the United States to develop a better understanding of local clean energy policy development and the interaction between state and local policies. To date, the majority of clean energy policy research focuses on the state and federal levels. While there has been a substantial amount of research on local level climate change initiatives, this is one of the first analyses of clean energy policies separate from climate change initiatives. This report is one in a suite of reports analyzing clean energy and climate policy development at the local, state, and regional levels.

  14. Clean Energy Policy Analyses. Analysis of the Status and Impact of Clean Energy Policies at the Local Level

    Energy Technology Data Exchange (ETDEWEB)

    Busche, S. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2010-12-01

    This report takes a broad look at the status of local clean energy policies in the United States to develop a better understanding of local clean energy policy development and the interaction between state and local policies. To date, the majority of clean energy policy research focuses on the state and federal levels. While there has been a substantial amount of research on local level climate change initiatives, this is one of the first analyses of clean energy policies separate from climate change initiatives. This report is one in a suite of reports analyzing clean energy and climate policy development at the local, state, and regional levels.

  15. Development of Zinc/Bromine Batteries for Load-Leveling Applications: Phase 2 Final Report

    Energy Technology Data Exchange (ETDEWEB)

    CLARK,NANCY H.; EIDLER,PHILLIP

    1999-10-01

    This report documents Phase 2 of a project to design, develop, and test a zinc/bromine battery technology for use in utility energy storage applications. The project was co-funded by the U.S. Department of Energy Office of Power Technologies through Sandia National Laboratories. The viability of the zinc/bromine technology was demonstrated in Phase 1. In Phase 2, the technology developed during Phase 1 was scaled up to a size appropriate for the application. Batteries were increased in size from 8-cell, 1170-cm{sup 2} cell stacks (Phase 1) to 8- and then 60-cell, 2500-cm{sup 2} cell stacks in this phase. The 2500-cm{sup 2} series battery stacks were developed as the building block for large utility battery systems. Core technology research on electrolyte and separator materials and on manufacturing techniques, which began in Phase 1, continued to be investigated during Phase 2. Finally, the end product of this project was a 100-kWh prototype battery system to be installed and tested at an electric utility.

  16. Use of a 33 MJ high-energy rotary impact testing machine for investigations into material behaviour under impact loads

    International Nuclear Information System (INIS)

    Issler, W.

    1989-01-01

    To investigate material behaviour under impact loads, previously very different testing machines have been developed. One of these concepts is the rotary impact testing machine which stores rotational energy and on which a tension impact test can be performed with almost unchanged trigger speed. With this device maximum trigger speeds can be achieved by using mechanical, elastically stored or hydraulic energy. Usable sample geometries include in particular smooth or notched round or flat tensile specimen up to 30 mm in diameter and CT10 or CT15 mechanical strength test specimen, permitting a direct comparison with results from quasi-static tests. For present speeds of load application the elastic modulus of steel can be considered as being constant. For Poisson's ratio, measurements indicated changes by approximately -8% to +20%. Early tests to investigate the strain rate showed that the strain rate under purely elastic loads applied to smooth round tensile specimen is approximately 3-10 times slower than the strain rate under plastic deformation, while this ratio may have an order of magnitude of 1:100 for notched tensile specimen. Therefore it is unreasonable to indicate only one value for the strain rate as a test characterising parameter. (orig./MM) [de

  17. the effect of dietary energy and protein levels on the composition

    African Journals Online (AJOL)

    Zannel

    Keywords: Breeding ostriches, nutrition, energy, protein, amino acids, egg ... Yolk is an important nutritional component of the avian egg because .... 3 (energy) x 3 (protein) factorial design with energy and protein levels featuring as main factors. ... No significant interactions were observed between energy and protein levels.

  18. Reviewing the Role of Cognitive Load, Expertise Level, Motivation, and Unconscious Processing in Working Memory Performance

    Science.gov (United States)

    Kuldas, Seffetullah; Hashim, Shahabuddin; Ismail, Hairul Nizam; Abu Bakar, Zainudin

    2015-01-01

    Human cognitive capacity is unavailable for conscious processing of every amount of instructional messages. Aligning an instructional design with learner expertise level would allow better use of available working memory capacity in a cognitive learning task. Motivating students to learn consciously is also an essential determinant of the capacity…

  19. Homocysteine levels -before and after methionine loading- in 51 Dutch families

    NARCIS (Netherlands)

    Heijer, den M.; Graafsma, S.; Lee, S.Y.; Verhoef, P.

    2005-01-01

    Elevated levels of homocysteine are a risk factor for vascular disease, thrombosis, neural tube defects and dementia. The 677C>T polymorphism in the methylenetetrahydrofolate reductase (MTHFR) gene appears to be the most important single determinant of plasma homocysteine concentration. In the

  20. Neutral-point voltage dynamic model of three-level NPC inverter for reactive load

    DEFF Research Database (Denmark)

    Maheshwari, Ram Krishan; Munk-Nielsen, Stig; Busquets-Monge, Sergio

    2012-01-01

    A three-level neutral-point-clamped inverter needs a controller for the neutral-point voltage. Typically, the controller design is based on a dynamic model. The dynamic model of the neutral-point voltage depends on the pulse width modulation technique used for the inverter. A pulse width modulati...

  1. A distributed fluid level sensor suitable for monitoring fuel load on board a moving fuel tank

    Science.gov (United States)

    Arkwright, John W.; Parkinson, Luke A.; Papageorgiou, Anthony W.

    2018-02-01

    A temperature insensitive fiber Bragg grating sensing array has been developed for monitoring fluid levels in a moving tank. The sensors are formed from two optical fibers twisted together to form a double helix with pairs of fiber Bragg gratings located above one another at the points where the fibers are vertically disposed. The sensing mechanism is based on a downwards deflection of the section of the double helix containing the FBGs which causes the tension in the upper FBG to decrease and the tension in the lower FBG to increase with concomitant changes in Bragg wavelength in each FBG. Changes in ambient temperature cause a common mode increase in Bragg wavelength, thus monitoring the differential change in wavelength provides a temperature independent measure of the applied pressure. Ambient temperature can be monitored simultaneously by taking the average wavelength of the upper and lower FBGs. The sensors are able to detect variations in pressure with resolutions better than 1 mmH2O and when placed on the bottom of a tank can be used to monitor fluid level based on the recorded pressure. Using an array of these sensors located along the bottom of a moving tank it was possible to monitor the fluid level at multiple points and hence dynamically track the total fluid volume in the tank. The outer surface of the sensing array is formed from a thin continuous Teflon sleeve, making it suitable for monitoring the level of volatile fluids such as aviation fuel and gasoline.

  2. City-Level Energy Decision Making. Data Use in Energy Planning, Implementation, and Evaluation in U.S. Cities

    Energy Technology Data Exchange (ETDEWEB)

    Aznar, Alexandra [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Day, Megan [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Doris, Elizabeth [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Mathur, Shivani [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Donohoo-Vallett, Paul [U.S. Department of Energy, Washington, DC (United States)

    2015-07-08

    The Cities-LEAP technical report, City-Level Energy Decision Making: Data Use in Energy Planning, Implementation, and Evaluation in U.S. Cities, explores how a sample of cities incorporates data into making energy-related decisions. This report provides the foundation for forthcoming components of the Cities-LEAP project that will help cities improve energy decision making by mapping specific city energy or climate policies and actions to measurable impacts and results.

  3. The effect of different accentuated eccentric load levels in eccentric-concentric loading contractions on acute neuromuscular, growth hormone and blood lactate responses during a hypertrophic protocol

    OpenAIRE

    Ojasto, Timo

    2007-01-01

    When accentuated load is applied during the eccentric (ECC) phase of eccentric-concentric (ECC-CON) contractions, it is defined as dynamic accentuated external resistance (DAER) exercise. This study monitored acute neuromuscular responses, growth hormone (GH) and blood lactate (La) concentrations to find out the most efficient ECC-CON loading strategy for muscle hypertrophy by employing various DAER resistances in the bench-press. Male subjects (age=32.4±4.3years, n=11) were assigned as subje...

  4. Nested-scale discharge and groundwater level monitoring to improve predictions of flow route discharges and nitrate loads

    Science.gov (United States)

    van der Velde, Y.; Rozemeijer, J. C.; de Rooij, G. H.; van Geer, F. C.; Torfs, P. J. J. F.; de Louw, P. G. B.

    2010-10-01

    Identifying effective measures to reduce nutrient loads of headwaters in lowland catchments requires a thorough understanding of flow routes of water and nutrients. In this paper we assess the value of nested-scale discharge and groundwater level measurements for predictions of catchment-scale discharge and nitrate loads. In order to relate field-site measurements to the catchment-scale an upscaling approach is introduced that assumes that scale differences in flow route fluxes originate from differences in the relationship between groundwater storage and the spatial structure of the groundwater table. This relationship is characterized by the Groundwater Depth Distribution (GDD) curve that relates spatial variation in groundwater depths to the average groundwater depth. The GDD-curve was measured for a single field site (0.009 km2) and simple process descriptions were applied to relate the groundwater levels to flow route discharges. This parsimonious model could accurately describe observed storage, tube drain discharge, overland flow and groundwater flow simultaneously with Nash-Sutcliff coefficients exceeding 0.8. A probabilistic Monte Carlo approach was applied to upscale field-site measurements to catchment scales by inferring scale-specific GDD-curves from hydrographs of two nested catchments (0.4 and 6.5 km2). The estimated contribution of tube drain effluent (a dominant source for nitrates) decreased with increasing scale from 76-79% at the field-site to 34-61% and 25-50% for both catchment scales. These results were validated by demonstrating that a model conditioned on nested-scale measurements simulates better nitrate loads and better predictions of extreme discharges during validation periods compared to a model that was conditioned on catchment discharge only.

  5. Single Particle energy levels in ODD-A Nuclei

    International Nuclear Information System (INIS)

    Lasijo, R.S.

    1997-01-01

    Singe particle energies for atomic nuclei with odd-A number of nucleons, i.e. nuclei possessing odd number of protons or odd number of neutrons, were calculated based on Nilsson's theory, and then the diagrams were made. the energy diagram is in the from of plot of energies as function of deformations, entities identifying the deviations from the spherical shape. The energy calculations were done using FORTRAN 77 language of PC (Personal Computer) version with Microsoft Fortran Power Station compiler, which was then combined with WORD version 6.0 and EXCEL version 5.0 of WINDOWS WORKGROUP to make the plot

  6. Levels and patterns of HIV RNA viral load in untreated pregnant women

    DEFF Research Database (Denmark)

    NN, NN; Patel, Deven; Thorne, Claire

    2008-01-01

    OBJECTIVE: To assess pregnancy levels and patterns of HIV RNA in the absence of antiretroviral therapy, while appropriately adjusting for potential confounders, including maternal immune status and race. METHODS: Data on > or = 1 antenatal HIV RNA measurements were available for 333 untreated HIV......-infected pregnant women enrolled in the European Collaborative Study. CD4 counts and HIV RNA measurements were routinely collected from 1992 and 1998, respectively. Linear mixed effects models based on 246 women for whom complete data were available examined changes in HIV RNA levels over pregnancy, with a nested...... random effects term accounting for measurement variability within women and period of sample collection. RESULTS: The change in HIV RNA over pregnancy varied significantly by race (p=0.005): from the second trimester until delivery, HIV RNA decreased significantly by an estimated 0.019 log(10) copies...

  7. Separation of palladium from high-level waste using metal ferro cyanide loaded resins

    International Nuclear Information System (INIS)

    Valsala, T.P.; Joseph, Annie; Yeotikar, R.G.

    2005-01-01

    High-level waste (HLW) is generated during reprocessing of spent fuel. HLW contains corrosion products, unextracted actinides, process chemicals and fission products. A recent trend is there to consider waste as a source of wealth. Among the fission products separation and recovery of platinum group metals have gained great attention. HLW is a good source of palladium of the platinum group metal. The present study shows the feasibility of ion exchange separation of Pd from HLW. (author)

  8. Department of Energy pretreatment of high-level and low-level wastes

    International Nuclear Information System (INIS)

    McGinnis, C.P.; Hunt, R.D.

    1995-01-01

    The remediation of the 1 x 10 8 gal of highly radioactive waste in the underground storage tanks (USTs) at five US Department of Energy (DOE) sites is one of DOE's greatest challenges. Therefore, the DOE Office of Environmental Management has created the Tank Focus Area (TFA) to manage an integrated technology development program that results in the safe and efficient remediation of UST waste. The TFA has divided its efforts into five areas, which are safety, characterization, retrieval/closure, pretreatment, and immobilization. All DOE pretreatment activities are integrated by the Pretreatment Technical Integration Manager of the TFA. For FY 1996, the 14 pretreatment tasks are divided into 3 systems: supernate separations, sludge treatment, and solid/liquid separation. The plans and recent results of these TFA tasks, which include two 25,000-gal demonstrations and two former TFA tasks on Cs removal, are presented. The pretreatment goals are to minimize the volume of high-level waste and the radioactivity in low-level waste

  9. Optimal fuzzy logic-based PID controller for load-frequency control including superconducting magnetic energy storage units

    International Nuclear Information System (INIS)

    Pothiya, Saravuth; Ngamroo, Issarachai

    2008-01-01

    This paper proposes a new optimal fuzzy logic-based-proportional-integral-derivative (FLPID) controller for load frequency control (LFC) including superconducting magnetic energy storage (SMES) units. Conventionally, the membership functions and control rules of fuzzy logic control are obtained by trial and error method or experiences of designers. To overcome this problem, the multiple tabu search (MTS) algorithm is applied to simultaneously tune PID gains, membership functions and control rules of FLPID controller to minimize frequency deviations of the system against load disturbances. The MTS algorithm introduces additional techniques for improvement of search process such as initialization, adaptive search, multiple searches, crossover and restarting process. Simulation results explicitly show that the performance of the optimum FLPID controller is superior to the conventional PID controller and the non-optimum FLPID controller in terms of the overshoot, settling time and robustness against variations of system parameters

  10. Load estimator-based hybrid controller design for two-interleaved boost converter dedicated to renewable energy and automotive applications.

    Science.gov (United States)

    Bougrine, Mohamed; Benmiloud, Mohammed; Benalia, Atallah; Delaleau, Emmanuel; Benbouzid, Mohamed

    2017-01-01

    This paper is devoted to the development of a hybrid controller for a two-interleaved boost converter dedicated to renewable energy and automotive applications. The control requirements, resumed in fast transient and low input current ripple, are formulated as a problem of fast stabilization of a predefined optimal limit cycle, and solved using hybrid automaton formalism. In addition, a real time estimation of the load is developed using an algebraic approach for online adjustment of the hybrid controller. Mathematical proofs are provided with simulations to illustrate the effectiveness and the robustness of the proposed controller despite different disturbances. Furthermore, a fuel cell system supplying a resistive load through a two-interleaved boost converter is also highlighted. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.

  11. The impact of the hot tap water load pattern in the industrial hall on the energy yield from solar collectors

    Science.gov (United States)

    Fidorów-Kaprawyl, Natalia; Dudkiewicz, Edyta

    2017-11-01

    The systems using solar energy, popular in Poland, can be used to supply hot water for the installation used by employees of industrial halls. In manufacturing plants, employing a large number of people, the demand for hot water is practically constant throughout the year and is characterized by periodic use at the end of each work shift. Dynamics of the hot water consumption depends on the number of shifts as well as working days and holidays. Additionally the maximum hot tap water demand occurs in the whole period of installation operation. In polish climatic conditions the solar collectors' systems have the largest capacity in the summer, while in winter they need to be assisted. Beside that the supply of renewable energy is uneven and depends on weather conditions. In the paper the one-hour step analysis concerning the dependence of the load pattern of the hot tap water preparation system on the energy yield from solar collectors had been performed.

  12. Experimental analysis of energy absorption behaviour of Al-tube filled with pumice lightweight concrete under axial loading condition

    Science.gov (United States)

    Rajak, D. K.; Deshpande, P. G.; Kumaraswamidhas, L. A.

    2017-08-01

    This Paper aimed at experimental investigation of compressive behaviour of square tube filled with pumice lightweight concrete (PLC). Square section of 20×20×30 mm is investigated, which is the backbone structure. The compression deformation result shows the better folding mechanism, displacement value, and energy absorption. PLC concrete filled with aluminium thin-wall tubes has been revealed superior energy absorption capacity (EAC) under low strain rate at room temperature. Superior EAC resulted as a result of mutual deformation benefit between aluminium section and PLC is also analysed. PLC was characterised by Fourier Transform Infrared (FTIR) and Field Emission Scanning Electron Microscopy (FESEM), and Energy Dispersive X-ray Spectrometry (EDX) analysis for better understanding of material behaviour. Individual and comparative load bearing graphs is logged for better prospective of analysing. Novel approach aimed at validation of porous lightweight concrete for better lightweight EA filler material.

  13. Experimental analysis of flexibility change with different levels of power reduction by demand response activation on thermostat controlled loads

    DEFF Research Database (Denmark)

    Lakshmanan, Venkatachalam; Marinelli, Mattia; Hu, Junjie

    2017-01-01

    This paper studies the flexibility available with thermostatically controlled loads (TCLs) to provide power system services by demand response (DR) activation. Although the DR activation on TCLs can provide power system ancillary services, it is important to know how long such services can...... be provided for when different levels of power reduction are imposed. The flexibility change with different levels of power reduction is tested experimentally with domestic fridges used by real customers with unknown user interaction. The investigation quantifies the flexibility of household fridges...... and the impact of DR activation in terms of deviation in the average temperature. The maximum possible power reduction with the cluster of refrigerators is 67% and the available flexibility with the cluster of refrigerators is 10%. The resulting deviation in the average temperature is 14%....

  14. The level of energy sufficiency - why all the controversy?

    International Nuclear Information System (INIS)

    Maillard, D.

    2000-01-01

    It as become fashionable in certain circles to attempt to demolish the notion of energy sufficiency, a concept which is now seen as being archaic and unsuitable. To back up their claims, proponents of this standpoint take great pleasure in attacking the corresponding indicator - the rate of energy sufficiency calculated as a ratio of national primary energy production and the total consumption of primary energy (in the same unit and without climatic corrections). Confirming its precarious, conventional and debatable nature seems in their eyes to be the best means of ensuring that both the word, the concept and the measuring method of energy sufficiency are consigned to the dustbin of economic history. After having examined with perhaps a certain irony some of the usual criticisms, I intend to proceed with a re-examination of questions which in my eyes appear to be essential. (author)

  15. A simplified equivalent circuit model for simulation of Pb-acid batteries at load for energy storage application

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Wenhua H.; Zhu Ying [Center for Microfibrous Materials, Department of Chemical Engineering, 212 Ross Hall, Auburn University, AL 36849-5127 (United States); Tatarchuk, Bruce J., E-mail: brucet@eng.auburn.edu [Center for Microfibrous Materials, Department of Chemical Engineering, 212 Ross Hall, Auburn University, AL 36849-5127 (United States)

    2011-08-15

    Highlights: {yields} Pb-acid battery is reexamined in electrode structure and capacitance enhancement. {yields} Pb-acid batteries were tested through the electrochemical impedance at loads. {yields} Electrode behaviors are evaluated by simulation using an equivalent circuit model. {yields} A defective and a failed Pb-acid battery was used in non-destructive analysis. {yields} Potential applications are for power reserve and sustainable electricity storage. - Abstract: Three main types of battery chemistries in consideration for vehicle applications are Pb-acid, nickel-metal hydride, and lithium-ion batteries. Lead-acid batteries are widely used in traditional automotive applications for many years. Higher voltage, high-rate discharge capability, good specific energy, lower temperature performance, lower thermal management requirement, and low-cost in both manufacturing and recycling are the advantages of the rechargeable battery. Disadvantages of the lead-acid battery are: weight concerns of lead metal (lower energy density and lower power density) and limited cycle-life (especially in deep-cycle duties). If two major disadvantages have been significantly changed to a proper state to compete with other battery chemistries, the Pb-acid battery is still a good candidate in considering of cost/performance ratio. The lead-acid battery is always a good power source for fast starting of cold vehicles, for recharging from either a stop-start braking system, or for a charge from the engine itself, which consumes battery energy or stores electricity back into chemical energy. The main reasons for reexamining this battery chemistry are cost-savings and life-cycling considerations upon advances in electrode structure design and enhancement of capacitance behavior inside the battery pack. Several Pb-acid batteries were evaluated and tested through a unique method, i.e., the electrochemical impedance method at different loads, in order to characterize and further understand the

  16. A simplified equivalent circuit model for simulation of Pb-acid batteries at load for energy storage application

    International Nuclear Information System (INIS)

    Zhu, Wenhua H.; Zhu Ying; Tatarchuk, Bruce J.

    2011-01-01

    Highlights: → Pb-acid battery is reexamined in electrode structure and capacitance enhancement. → Pb-acid batteries were tested through the electrochemical impedance at loads. → Electrode behaviors are evaluated by simulation using an equivalent circuit model. → A defective and a failed Pb-acid battery was used in non-destructive analysis. → Potential applications are for power reserve and sustainable electricity storage. - Abstract: Three main types of battery chemistries in consideration for vehicle applications are Pb-acid, nickel-metal hydride, and lithium-ion batteries. Lead-acid batteries are widely used in traditional automotive applications for many years. Higher voltage, high-rate discharge capability, good specific energy, lower temperature performance, lower thermal management requirement, and low-cost in both manufacturing and recycling are the advantages of the rechargeable battery. Disadvantages of the lead-acid battery are: weight concerns of lead metal (lower energy density and lower power density) and limited cycle-life (especially in deep-cycle duties). If two major disadvantages have been significantly changed to a proper state to compete with other battery chemistries, the Pb-acid battery is still a good candidate in considering of cost/performance ratio. The lead-acid battery is always a good power source for fast starting of cold vehicles, for recharging from either a stop-start braking system, or for a charge from the engine itself, which consumes battery energy or stores electricity back into chemical energy. The main reasons for reexamining this battery chemistry are cost-savings and life-cycling considerations upon advances in electrode structure design and enhancement of capacitance behavior inside the battery pack. Several Pb-acid batteries were evaluated and tested through a unique method, i.e., the electrochemical impedance method at different loads, in order to characterize and further understand the improved electrode

  17. FY 1998 report on achievements of the verification survey on a new method for load leveling; Fuka heijunka shinshuho jissho chosa 1998 nendo seika hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    An electrically double-layered capacitor is drawing attention as a new power storage technology that can contribute to power load leveling. The issue is to make the capacitor more compact by enhancing energy density. Discussions to improve the energy density are being given on a method by which internal resistance combined with that in electronic circuits may be allowed to some extent. In addition, in order to verify feasibility of its practical use, investigations are made on the optimal operation pattern of the system, possible quantity of introduction, effect of the introduction, and future possibility to reduce the cost. As demonstration of the element technology used in capacitor modules, fiscal 1997 fabricated 35 single cells each with a volume of one liter, and investigated the positioning at practical application, case studies, and operation patterns. Based on the achievements in fiscal 1997, fiscal 1998 performed fabrication and performance test on a capacitor module in which multiple number of cells are connected, and trial fabrication of a next generation type high-energy density capacitor. In addition, as a study on a total system, discussions were given on design and cost estimation of a hybrid type capacitor which combines the capacitor with a NAS battery. (NEDO)

  18. Coordinated control of smart microgrid during and after islanding operation to prevent under frequency load shedding using energy storage system

    International Nuclear Information System (INIS)

    Koohi-Kamali, Sam; Rahim, Nasrudin Abd

    2016-01-01

    Highlights: • A new power management system is proposed. • The novel idea of using energy storage systems to prevent under frequency load shedding is presented. • A method to estimate rate of change of frequency in islanding mode and to dispatch battery plant is introduced. • Two effective outer control loops are proposed for governor to synchronize the microgrid with main grid. • Solar photovoltaic and battery plants bring the voltage regulation ancillary service for microgrid. - Abstract: This work presents a smart microgrid consisting of diesel, photovoltaic (PV), and battery storage plants. One of the key features of smart grid is to provide a redundant high quality power for the consumers. In islanded microgrid, the under frequency and/or voltage collapse, caused by power deficiency, can lead to power outage. The current practice is to shed the load demand until the frequency and voltage are restored. However, the redundancy in supplying power has no meaning as long as the loads are shed. The main objective of this paper is to propose a power management system (PMS) that protects the microgrid against the load shedding. PMS is able to control the microgrid in both centralized and decentralized fashions. To prevent under frequency load shedding (UFLS), this work proposes using battery energy storage system (BESS) to compensate for the power mismatch in the islanded microgrid. A method is presented to estimate the rate of change of frequency and to calculate the power deficiency. The approximated value is exploited as the set-point to dispatch BESS. PV and battery plants are supposed to share the reactive power demand proportionally and thus regulate the voltage at the load bus. This work also suggests two outer control loops, namely, frequency restoration loop (FRL) and difference angle compensator (DAC). These loops ensure microgrid smooth transition from islanded mode to grid-connected mode. The microgrid is configured to investigate the effective

  19. Iron Loading Selectively Increases Hippocampal Levels of Ubiquitinated Proteins and Impairs Hippocampus-Dependent Memory.

    Science.gov (United States)

    Figueiredo, Luciana Silva; de Freitas, Betânia Souza; Garcia, Vanessa Athaíde; Dargél, Vinícius Ayub; Köbe, Luiza Machado; Kist, Luiza Wilges; Bogo, Maurício Reis; Schröder, Nadja

    2016-11-01

    Alterations of brain iron levels have been observed in a number of neurodegenerative disorders. We have previously demonstrated that iron overload in the neonatal period results in severe and persistent memory deficits in the adulthood. Protein degradation mediated by the ubiquitin-proteasome system (UPS) plays a central regulatory role in several cellular processes. Impairment of the UPS has been implicated in the pathogenesis of neurodegenerative disorders. Here, we examined the effects of iron exposure in the neonatal period (12th-14th day of postnatal life) on the expression of proteasome β-1, β-2, and β-5 subunits, and ubiquitinated proteins in brains of 15-day-old rats, to evaluate the immediate effect of the treatment, and in adulthood to assess long-lasting effects. Two different memory types, emotionally motivated conditioning and object recognition were assessed in adult animals. We found that iron administered in the neonatal period impairs both emotionally motivated and recognition memory. Polyubiquitinated protein levels were increased in the hippocampus, but not in the cortex, of adult animals treated with iron. Gene expression of subunits β1 and β5 was affected by age, being higher in the early stages of development in the hippocampus, accompanied by an age-related increase in polyubiquitinated protein levels in adults. In the cortex, gene expression of the three proteasome subunits was significantly higher in adulthood than in the neonatal period. These findings suggest that expression of proteasome subunits and activity are age-dependently regulated. Iron exposure in the neonatal period produces long-lasting harmful effects on the UPS functioning, which may be related with iron-induced memory impairment.

  20. Guaranteed and computable bounds of the limit load for variational problems with linear growth energy functionals

    Czech Academy of Sciences Publication Activity Database

    Haslinger, Jaroslav; Repin, S.; Sysala, Stanislav

    2016-01-01

    Roč. 61, č. 5 (2016), s. 527-564 ISSN 0862-7940 R&D Projects: GA MŠk LQ1602 Institutional support: RVO:68145535 Keywords : functionals with linear growth * limit load * truncation method * perfect plasticity Subject RIV: BA - General Mathematics Impact factor: 0.618, year: 2016 http://link.springer.com/article/10.1007/s10492-016-0146-6

  1. Nonlinear methods for load and energy forecasting in local energy systems, especially wind power and photovoltaic systems. Final report

    International Nuclear Information System (INIS)

    Kantz, H.; Ragwitz, M.

    2002-05-01

    The investigations were supported by the Center for Nonlinear Dynamics in Austin, Texas, the Department of Energy and Semiconductor Engineering of Oldenburg University, and Boreas Energietechnik GmbH in Dresden, Germany [de

  2. Energy-level scheme and transition probabilities of Si-like ions

    International Nuclear Information System (INIS)

    Huang, K.N.

    1984-01-01

    Theoretical energy levels and transition probabilities are presented for 27 low-lying levels of silicon-like ions from Z = 15 to Z = 106. The multiconfiguration Dirac-Fock technique is used to calculate energy levels and wave functions. The Breit interaction and Lamb shift contributions are calculated perturbatively as corrections to the Dirac-Fock energy. The M1 and E2 transitions between the first nine levels and the E1 transitions between excited and the ground levels are presented

  3. Real-Time Vehicle Energy Management System Based on Optimized Distribution of Electrical Load Power

    OpenAIRE

    Yuefei Wang; Hao Hu; Li Zhang; Nan Zhang; Xuhui Sun

    2016-01-01

    As a result of severe environmental pressure and stringent government regulations, refined energy management for vehicles has become inevitable. To improve vehicle fuel economy, this paper presents a bus-based energy management system for the electrical system of internal combustion engine vehicles. Both the model of an intelligent alternator and the model of a lead-acid battery are discussed. According to these models, the energy management for a vehicular electrical system is formulated as ...

  4. Reducing Plug and Process Loads for a Large Scale, Low Energy Office Building: NREL's Research Support Facility; Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Lobato, C.; Pless, S.; Sheppy, M.; Torcellini, P.

    2011-02-01

    This paper documents the design and operational plug and process load energy efficiency measures needed to allow a large scale office building to reach ultra high efficiency building goals. The appendices of this document contain a wealth of documentation pertaining to plug and process load design in the RSF, including a list of equipment was selected for use.

  5. Study of excitation energy dependence of nuclear level density parameter

    International Nuclear Information System (INIS)

    Mohanto, G.; Nayak, B.K.; Saxena, A.

    2016-01-01

    In the present study, we have populated CN by fusion reaction and excitation energy of the intermediate nuclei is determined after first chance α-emission to investigate excitation energy dependence of the NLD parameter. Evaporated neutron spectra were measured following alpha evaporation for obtaining NLD parameter for the reaction 11 B + 197 Au, populating CN 208 Po. This CN after evaporating an α-particle populates intermediate nucleus 204 Pb. The 204 Pb has magic number of Z=82. Our aim is to study the excitation energy dependence of NLD parameter for closed shell nuclei

  6. Energy intensity, target level of energy intensity, and room for improvement in energy intensity: An application to the study of regions in the EU

    International Nuclear Information System (INIS)

    Chang, Ming-Chung

    2014-01-01

    While the previous literature shows that a decline in energy intensity represents an improvement in energy use efficiency, it does not provide a target level of energy intensity, nor what room for improvement in terms of energy intensity could entail. This study establishes an indicator of such room for improvement in terms of energy intensity by measuring the difference between the target level of energy intensity and the actual energy intensity and thereby monitors energy use efficiency. The traditional indicator of energy intensity, defined as energy use over GDP, mainly estimates energy use efficiency, but is a partial effect between the energy input and GDP output. However, our proposed indicator of the room for improvement in terms of energy intensity is the total-factor effects based on the multiple-inputs model. By taking the 27 EU members to investigate their energy use efficiency using the indicator of the room for improvement in terms of energy intensity, this study concludes that an improvement in energy intensity does not fully depend on a decline in energy intensity, and we instead need to confirm whether the room for improvement in terms of energy intensity decreases. This finding is particularly relevant for energy policy-makers. - Highlights: • This paper establishes an indicator for the room for improvement in terms of energy intensity. • This study takes the 27 EU members to investigate their energy use efficiency. • A different result appears by using our proposed indicator

  7. Load Shifting and Storage of Cooling Energy through Ice Bank or Ice Slurry Systems: modelling and experimental analysis

    Energy Technology Data Exchange (ETDEWEB)

    Grozdek, Marino

    2009-10-15

    Ice based Cool Thermal Energy Storage (CTES) systems have attracted much attention during last few decades. The reasons are mainly of economical and environmental nature. Compared to conventional refrigeration and air-conditioning systems without cool thermal energy storage, implementation of CTES will increase environmental standards and overall efficiency of the energy systems as it contributes to the phase-out of synthetic refrigerants and reduces peak loads in electricity grids. For the application of a cool thermal energy storages in refrigeration installations and HVAC systems in industry and building sector, it is necessary to have appropriate design tools in order to sufficiently accurate predict their performance. In this thesis theoretical and experimental investigations of two ice based cool thermal energy storage systems, namely static, indirect, external melt, ice-on-coil, i.e. ice bank system and dynamic, ice slurry cool thermal energy storage system are carried out. An ice bank storage technology for cooling purposes is known for a long time. The main drawbacks which are hindering its wider use are the system complexity, high first costs, system efficiency which is highly dependant on design, control and monitoring of the system, etc. On the other hand, ice slurry technology was not well studied until recently, while in the current scientific literature there are still differences between results and conclusions reported by different investigators. The aim of the present thesis is to extend the knowledge in the field of ice based CTES systems, thereby contributing in the development and wider utilization of those systems. In the first part of the thesis a computer application, named 'BankaLeda' is presented. It enables simulation of an ice bank system performance. In order to verify developed simulation model an experimental evaluation has been performed. Field measurements have been conducted on a two module silo which was installed as a

  8. Decentralized resource allocation and load scheduling for multicommodity smart energy systems

    NARCIS (Netherlands)

    Blaauwbroek, N.; Nguyen, H.P.; Konsman, M.J.; Shi, H.; Kamphuis, I.G.; Kling, W.L.

    2015-01-01

    Due to the expected growth in district heating systems in combination with the development of hybrid energy appliances such as heat pumps (HPs) and micro-combined heat and power (CHP) installations, new opportunities arise for the management of multicommodity energy systems, including electricity,

  9. Optimal resource allocation and load scheduling for a multi-commodity smart energy system

    NARCIS (Netherlands)

    Blaauwbroek, N.; Nguyen, H.P.; Shi, H.; Kamphuis, I.G.; Kling, W.L.; Konsman, M.J.

    2015-01-01

    The increasing introduction of district heating systems together with hybrid energy appliances as heat pumps and micro-combined heat and power installations, results in new opportunities for optimizing the available resources in multi-commodity smart energy systems, including electricity, heat and

  10. Load Shifting Control and Management of Domestic Microgeneration Systems for Improved Energy Efficiency and Comfort

    DEFF Research Database (Denmark)

    Anvari-Moghaddam, Amjad; Quintero, Juan Carlos Vasquez; Guerrero, Josep M.

    2015-01-01

    In this paper, an intelligent energy management system based on energy saving and user’s comfort is introduced and applied to a residential smart home as a case study. The proposed multi-objective mixed-integer nonlinear programming (MINLP)-based architecture takes the advantages of several key...

  11. Development of methods for evaluation of electricity saving and load levelling measures. Part 2: The planning and implementation of a power conservation campaign

    Energy Technology Data Exchange (ETDEWEB)

    Storm Soerensen, M.; Madsen, P.K. [NESA A/S, Research and Development Dept. (Denmark)

    1997-12-01

    In recent years many campaigns and projects have been carried out with the purpose of reducing the energy consumption. Simultaneously a lot of economic and structural changes are taking place in society in general; changes which also affect the size of the electricity consumption. Furthermore, there is a trend towards increased use of wind mills and decentral combined heating and power plants, which affects the electricity load of the local area. It is difficult to identify and separate the effect of each of these attitude-adjusting activities. The project `Development of methods for evaluation of the effect of electricity saving and load levelling measures` focuses on two different methods which, on different levels, can be used to determine the impact of different different activities on the electricity consumption. Both methods are based on mathematical statistics, and they consist of an analysis of historical data and a test campaign which will make it possible to test specific activities in a comparatively small scale. The historical part covers the years 1974 to 1994 and include such variables as: demography, economic factors, climatic conditions, periods of electricity saving campaigns, the start of billing according to time of day tariff etc. The wish to be able to measure the extent of these energy saving and load reducing initiatives resulted in a test campaign which was carried out under very restricted conditions starting in the fall of 1996. If the effect of the test campaign can be measured and as a consequence of this a method can be estimated, it will be possible to place models which can measure the effect of future campaigns. The primary object of the campaign is not the size of the electricity savings of the individual customer, but rather to obtain total savings for the entire group of customers. The test has been structured in a way which makes it possible to perform an analysis of the effect of the campaign by use of analysis of intervention

  12. A Rotational and Axial Motion System Load Frame Insert for In Situ High Energy X-Ray Studies (Postprint)

    Science.gov (United States)

    2015-09-08

    Paul A. Shade, Jay C. Schuren, and Todd J. Turner AFRL/RX Basil Blank PulseRay Peter Kenesei, Kurt Goetze, Ulrich Lienert, and Jonathan Almer...AFRL/RX 2) Basil Blank – PulseRay (continued on page 2) 5d. PROJECT NUMBER 4349 5e. TASK NUMBER 0001 5f...2015) A rotational and axial motion system load frame insert for in situ high energy x-ray studies Paul A. Shade,1,a) Basil Blank,2 Jay C. Schuren,1,b

  13. Optimal Scheduling of Distributed Energy Resources and Responsive Loads in Islanded Microgrids Considering Voltage and Frequency Security Constraints

    DEFF Research Database (Denmark)

    Vahedipour-Dahraie, Mostafa; Najafi, Hamid Reza; Anvari-Moghaddam, Amjad

    2018-01-01

    in islanded MGs with regard to voltage and frequency security constraints. Based on the proposed model, scheduling of the controllable units in both supply and demand sides is done in a way not only to maximize the expected profit of MG operator (MGO), but also to minimize the energy payments of customers...... on the system’s performance in terms of voltage and frequency stability. Moreover, optimal coordination of DERs and responsive loads can increase the expected profit of MGO significantly. The effectiveness of the proposed scheduling approach is verified on an islanded MG test system over a 24-h period....

  14. Effect of methionine load on homocysteine levels, lipid peroxidation and DNA damage in rats receiving ethanol

    Directory of Open Access Journals (Sweden)

    Alceu Afonso Jordao Júnior

    2009-12-01

    Full Text Available Changes in the metabolism of methionine can cause hyperhomocysteinemia, inducing a triad of atherosclerosis, hypertension, and increased oxidative stress. The generation of free radicals and oxidative damage to DNA is important in the liver damage caused by ethanol. In this study, the effect of methionine overload associated or otherwise with acute administration of ethanol on homocysteine values, damage to DNA, lipoperoxidation and vitamin E was evaluated. Thirty rats were divided into 3 groups: Group Ethanol 24 hours (EG24, Group Methionine 24 hours (MG24, and Group Methionine and Ethanol 24 hours (MEG24. TBARS, vitamin E, GS and, homocysteine values were determined and the Comet assay was carried out. Increased GSH, vitamin E and homocysteine levels were observed for MEG24, and increased TBARS were observed in EG24. The Comet assay showed an increase in DNA damage in EG24 and DNA protection in MEG24. The administration of ethanol decreased antioxidant levels and increased TBARS, indicating the occurrence of oxidative stress with possible DNA damage. The combination of methionine and ethanol had a protective effect against the ethanol-induced damage, but increased the levels of homocysteine.Alterações no metabolismo da metionina podem ocasionar hiper-homocisteinemia, quadro indutivo de aterosclerose, hipertensão e aumento do estresse oxidativo. A geração de radicais livres e dano oxidativo ao DNA são importantes na injúria hepática provocada pelo etanol. Neste estudo avaliaram-se os efeitos da sobrecarga de metionina associada ou não à administração aguda de etanol sobre valores de homocisteína, dano ao DNA, lipoperoxidação e vitamina E. Foram utilizados 30 ratos Wistar distribuídos em 3 Grupos: Grupo Etanol 24 horas (GE24, Grupo Metionina 24 horas (GM24 e Grupo Metionina e Etanol 24 horas (GME24. Realizaram-se determinações hepáticas de SRATB, vitamina E, GSH, homocisteína e Teste do Cometa e determinações plasm

  15. After-hours power status of office equipment and energy use of miscellaneous plug-load equipment

    Energy Technology Data Exchange (ETDEWEB)

    Roberson, Judy A.; Webber, Carrie A.; McWhinney, Marla C.; Brown, Richard E.; Pinckard, Marageret J.; Busch, John F.

    2004-05-27

    This research was conducted in support of two branches of the EPA ENERGY STAR program, whose overall goal is to reduce, through voluntary market-based means, the amount of carbon dioxide emitted in the U.S. The primary objective was to collect data for the ENERGY STAR Office Equipment program on the after-hours power state of computers, monitors, printers, copiers, scanners, fax machines, and multi-function devices. We also collected data for the ENERGY STAR Commercial Buildings branch on the types and amounts of miscellaneous plug-load equipment, a significant and growing end use that is not usually accounted for by building energy managers. For most types of miscellaneous equipment, we also estimated typical unit energy consumption in order to estimate total energy consumption of the miscellaneous devices within our sample. This data set is the first of its kind that we know of, and is an important first step in characterizing miscellaneous plug loads in commercial buildings. The main purpose of this study is to supplement and update previous data we collected on the extent to which electronic office equipment is turned off or automatically enters a low power state when not in active use. In addition, it provides data on numbers and types of office equipment, and helps identify trends in office equipment usage patterns. These data improve our estimates of typical unit energy consumption and savings for each equipment type, and enables the ENERGY STAR Office Equipment program to focus future effort on products with the highest energy savings potential. This study expands our previous sample of office buildings in California and Washington DC to include education and health care facilities, and buildings in other states. We report data from sixteen commercial buildings in California, Georgia, and Pennsylvania: four education buildings, two medical buildings, two large offices (> 500 employees each), three medium offices (50-500 employees each), and five small

  16. Optimal sizing of small wind/battery systems considering the DC bus voltage stability effect on energy capture, wind speed variability, and load uncertainty

    International Nuclear Information System (INIS)

    Lujano-Rojas, Juan M.; Dufo-López, Rodolfo; Bernal-Agustín, José L.

    2012-01-01

    Highlights: ► We propose a mathematical model for optimal sizing of small wind energy systems. ► No other previous work has considered all the aspects included in this paper. ► The model considers several parameters about batteries. ► Wind speed variability is considered by means of ARMA model. ► The results show how to minimize the expected energy that is not supplied. - Abstract: In this paper, a mathematical model for stochastic simulation and optimization of small wind energy systems is presented. This model is able to consider the operation of the charge controller, the coulombic efficiency during charge and discharge processes, the influence of temperature on the battery bank capacity, the wind speed variability, and load uncertainty. The joint effect of charge controller operation, ambient temperature, and coulombic efficiency is analyzed in a system installed in Zaragoza (Spain), concluding that if the analysis without considering these factors is carried out, the reliability level of the physical system could be lower than expected, and an increment of 25% in the battery bank capacity would be required to reach a reliability level of 90% in the analyzed case. Also, the effect of the wind speed variability and load uncertainty in the system reliability is analyzed. Finally, the uncertainty in the battery bank lifetime and its effect on the net present cost are discussed. The results showed that, considering uncertainty of 17.5% in the battery bank lifetime calculated using the Ah throughput model, about 12% of uncertainty in the net present cost is expected. The model presented in this research could be a useful stochastic simulation and optimization tool that allows the consideration of important uncertainty factors in techno-economic analysis.

  17. "Watts per person" paradigm to design net zero energy buildings: Examining technology interventions and integrating occupant feedback to reduce plug loads in a commercial building

    Science.gov (United States)

    Yagi Kim, Mika

    As building envelopes have improved due to more restrictive energy codes, internal loads have increased largely due to the proliferation of computers, electronics, appliances, imaging and audio visual equipment that continues to grow in commercial buildings. As the dependency on the internet for information and data transfer increases, the electricity demand will pose a challenge to design and operate Net Zero Energy Buildings (NZEBs). Plug Loads (PLs) as a proportion of the building load has become the largest non-regulated building energy load and represents the third highest electricity end-use in California's commercial office buildings, accounting for 23% of the total building electricity consumption (Ecova 2011,2). In the Annual Energy Outlook 2008 (AEO2008), prepared by the Energy Information Administration (EIA) that presents long-term projections of energy supply and demand through 2030 states that office equipment and personal computers are the "fastest growing electrical end uses" in the commercial sector. This thesis entitled "Watts Per Person" Paradigm to Design Net Zero Energy Buildings, measures the implementation of advanced controls and behavioral interventions to study the reduction of PL energy use in the commercial sector. By integrating real world data extracted from an energy efficient commercial building of its energy use, the results produce a new methodology on estimating PL energy use by calculating based on "Watts Per Person" and analyzes computational simulation methods to design NZEBs.

  18. Special physical preparation of athletes in motor sport during testing methods basic training level of preparedness for competitive athlete load

    Directory of Open Access Journals (Sweden)

    Cherednychenko M.A.

    2014-03-01

    Full Text Available Purpose: to establish the reasons for the high fatigue pilots during passage race course. Material : the study involved athletes and race car drivers depending on the rank of the competition. The total number surveyed was 140 people. Results : in vitro studies have established a pattern of growth of errors in the evaluation of the available jobs at different levels of fatigue. This asymmetry observed in the haptic display and reflex mean arterial pressure when simultaneous registration on the left and right side body. After the competition and training at a special physical training were examined 36 athletes. Comparison of the results display asymmetry haptic reflex and mean arterial pressure showed reliable changes in the resistance of the organism to a specific exertion racers. Conclusions : the optimal load is characterized by indicators of coordination and reflex reaction haptic mean arterial pressure. These indicators do not go beyond the norms of its symmetrical appearance. This characterizes a uniform and sufficient blood supply body during the execution of competitive and training load.

  19. Special physical preparation of athletes in motor sport during testing methods basic training level of preparedness for competitive athlete load

    Directory of Open Access Journals (Sweden)

    M.A. Cherednychenko

    2014-04-01

    Full Text Available Purpose: to establish the reasons for the high fatigue pilots during passage race course. Material : the study involved athletes and race car drivers depending on the rank of the competition. The total number surveyed was 140 people. Results : in vitro studies have established a pattern of growth of errors in the evaluation of the available jobs at different levels of fatigue. This asymmetry observed in the haptic display and reflex mean arterial pressure when simultaneous registration on the left and right side body. After the competition and training at a special physical training were examined 36 athletes. Comparison of the results display asymmetry haptic reflex and mean arterial pressure showed reliable changes in the resistance of the organism to a specific exertion racers. Conclusions : the optimal load is characterized by indicators of coordination and reflex reaction haptic mean arterial pressure. These indicators do not go beyond the norms of its symmetrical appearance. This characterizes a uniform and sufficient blood supply body during the execution of competitive and training load.

  20. Load-Unload Response Ratio and Accelerating Moment/Energy Release Critical Region Scaling and Earthquake Prediction

    Science.gov (United States)

    Yin, X. C.; Mora, P.; Peng, K.; Wang, Y. C.; Weatherley, D.

    The main idea of the Load-Unload Response Ratio (LURR) is that when a system is stable, its response to loading corresponds to its response to unloading, whereas when the system is approaching an unstable state, the response to loading and unloading becomes quite different. High LURR values and observations of Accelerating Moment/Energy Release (AMR/AER) prior to large earthquakes have led different research groups to suggest intermediate-term earthquake prediction is possible and imply that the LURR and AMR/AER observations may have a similar physical origin. To study this possibility, we conducted a retrospective examination of several Australian and Chinese earthquakes with magnitudes ranging from 5.0 to 7.9, including Australia's deadly Newcastle earthquake and the devastating Tangshan earthquake. Both LURR values and best-fit power-law time-to-failure functions were computed using data within a range of distances from the epicenter. Like the best-fit power-law fits in AMR/AER, the LURR value was optimal using data within a certain epicentral distance implying a critical region for LURR. Furthermore, LURR critical region size scales with mainshock magnitude and is similar to the AMR/AER critical region size. These results suggest a common physical origin for both the AMR/AER and LURR observations. Further research may provide clues that yield an understanding of this mechanism and help lead to a solid foundation for intermediate-term earthquake prediction.

  1. Differences in cardiovascular risk profile based on relationship between post-load plasma glucose and fasting plasma levels.

    Science.gov (United States)

    Succurro, Elena; Marini, Maria Adelaide; Grembiale, Alessandro; Lugarà, Marina; Andreozzi, Francesco; Sciacqua, Angela; Hribal, Marta Letizia; Lauro, Renato; Perticone, Francesco; Sesti, Giorgio

    2009-05-01

    It has been shown that subjects with normal glucose tolerance (NGT), whose plasma glucose (PG) levels do not return to their fasting PG level within 2 h during an oral glucose tolerance test (OGTT) (Group I), have a significantly higher risk to develop type 2 diabetes than NGT subjects whose 2-h glucose returns to, or drops below, the fasting level (Group I). However, it is still unsettled whether individuals in Group II have a more atherogenic profile than Group I subjects. To address this issue, we examined 266 non-diabetic offspring of type 2 diabetic patients, recruited in the context of EUGENE2 cross-sectional study. All subjects underwent an euglycaemic-hyperinsulinemic clamp to assess glucose tolerance and insulin sensitivity. Furthermore, cardiovascular risk factors and ultrasound measurement of carotid intima-media thickness (IMT) were evaluated. Individuals in Group II exhibited significantly higher waist circumference, blood pressure, triglycerides, 2-h post-load PG, hsC-reactive protein, interleukin-6, insulin-like growth factor-1 (IGF-1), IMT, and lower insulin sensitivity than subjects in Group I. Subjects with NGT, whose PG concentration does not return to their fasting PG level within 2 h during OGTT, have an atherogenic profile, suggesting that performing OGTT with measurement of PG every 30 min may be useful to assess the risk for cardiovascular disease in glucose-tolerant subjects.

  2. Recent results on high thermal energy load testing of beryllium for ITER first wall application

    Science.gov (United States)

    Kupriyanov, I. B.; Roedig, M.; Nikolaev, G. N.; Kurbatova, L. A.; Linke, J.; Gervash, A. A.; Giniyatulin, R. N.; Podkovyrov, V. L.; Muzichenko, A. D.; Khimchenko, L.

    2011-12-01

    In this paper, progress in the high heat flux (HHF) qualification testing of TGP-56FW beryllium grade for ITER first wall applications is presented. Two actively cooled Be/CuCrZr brazing mock-ups were tested under complex thermal loading conditions in the electron beam facility JUDITH-1 (step 1: vertical displacement event test at 40 MJ m-2, 0.3 s, 1 shot; step 2: disruption tests at 3 MJ m-2, 1 shot, Δt=5 ms; step 3: repetitive fatigue test at 80 MW m-2, 1000 shots, Δt=25 ms). After testing, metallographic investigations on the microstructure and crack morphology were carried out. The results of these studies of Be tiles are reported and discussed. The overall results of TGP-56FW grade qualification testing have demonstrated the reliable performance capability of TGP-56FW for application as the armor of the ITER first wall. In addition, the results of first experiments with TGP-56FW and S-65C beryllium grades in the QSPA-Be plasma gun facility are also reported. In these experiments, beryllium tiles (80×80×10 mm3) were tested in a hydrogen plasma stream (5 cm in diameter) with pulse duration 0.5 ms and heat loads of 0.5-2 MJ m-2. Experiments were performed at room temperature. The evolution of the surface microstructure and mass loss of beryllium exposed to up to 100 shots is presented.

  3. Recent results on high thermal energy load testing of beryllium for ITER first wall application

    International Nuclear Information System (INIS)

    Kupriyanov, I B; Nikolaev, G N; Kurbatova, L A; Roedig, M; Linke, J; Gervash, A A; Giniyatulin, R N; Podkovyrov, V L; Muzichenko, A D; Khimchenko, L

    2011-01-01

    In this paper, progress in the high heat flux (HHF) qualification testing of TGP-56FW beryllium grade for ITER first wall applications is presented. Two actively cooled Be/CuCrZr brazing mock-ups were tested under complex thermal loading conditions in the electron beam facility JUDITH-1 (step 1: vertical displacement event test at 40 MJ m - 2, 0.3 s, 1 shot; step 2: disruption tests at 3 MJ m - 2, 1 shot, Δt=5 ms; step 3: repetitive fatigue test at 80 MW m - 2, 1000 shots, Δt=25 ms). After testing, metallographic investigations on the microstructure and crack morphology were carried out. The results of these studies of Be tiles are reported and discussed. The overall results of TGP-56FW grade qualification testing have demonstrated the reliable performance capability of TGP-56FW for application as the armor of the ITER first wall. In addition, the results of first experiments with TGP-56FW and S-65C beryllium grades in the QSPA-Be plasma gun facility are also reported. In these experiments, beryllium tiles (80×80×10 mm 3 ) were tested in a hydrogen plasma stream (5 cm in diameter) with pulse duration 0.5 ms and heat loads of 0.5-2 MJ m - 2. Experiments were performed at room temperature. The evolution of the surface microstructure and mass loss of beryllium exposed to up to 100 shots is presented.

  4. Load Balancing Metric with Diversity for Energy Efficient Routing in Wireless Sensor Networks

    DEFF Research Database (Denmark)

    Moad, Sofiane; Hansen, Morten Tranberg; Jurdak, Raja

    2011-01-01

    The expected number of transmission (ETX) represents a routing metric that considers the highly variable link qualities for a specific radio in Wireless Sensor Networks (WSNs). To adapt to these differences, radio diversity is a recently explored solution for WSNs. In this paper, we propose...... an energy balancing metric which explores the diversity in link qualities present at different radios. The goal is to effectively use the energy of the network and therefore extend the network lifetime. The proposed metric takes into account the transmission and reception costs for a specific radio in order...... to choose an energy efficient radio. In addition, the metric uses the remaining energy of nodes in order to regulate the traffic so that critical nodes are avoided. We show by simulations that our metric can improve the network lifetime up to 20%....

  5. A rotational and axial motion system load frame insert for in situ high energy x-ray studies

    Energy Technology Data Exchange (ETDEWEB)

    Shade, Paul A., E-mail: paul.shade.1@us.af.mil; Schuren, Jay C.; Turner, Todd J. [Materials and Manufacturing Directorate, Air Force Research Laboratory, Wright-Patterson AFB, Ohio 45433 (United States); Blank, Basil [PulseRay, Beaver Dams, New York 14812 (United States); Kenesei, Peter; Goetze, Kurt; Lienert, Ulrich; Almer, Jonathan [Advanced Photon Source, Argonne National Laboratory, Argonne, Illinois 60439 (United States); Suter, Robert M. [Carnegie Mellon University, Pittsburgh, Pennsylvania 15213 (United States); Bernier, Joel V.; Li, Shiu Fai [Engineering Directorate, Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); Lind, Jonathan [Carnegie Mellon University, Pittsburgh, Pennsylvania 15213 (United States); Engineering Directorate, Lawrence Livermore National Laboratory, Livermore, California 94550 (United States)

    2015-09-15

    High energy x-ray characterization methods hold great potential for gaining insight into the behavior of materials and providing comparison datasets for the validation and development of mesoscale modeling tools. A suite of techniques have been developed by the x-ray community for characterizing the 3D structure and micromechanical state of polycrystalline materials; however, combining these techniques with in situ mechanical testing under well characterized and controlled boundary conditions has been challenging due to experimental design requirements, which demand new high-precision hardware as well as access to high-energy x-ray beamlines. We describe the design and performance of a load frame insert with a rotational and axial motion system that has been developed to meet these requirements. An example dataset from a deforming titanium alloy demonstrates the new capability.

  6. Energy matching and optimization analysis of waste to energy CCHP (combined cooling, heating and power) system with exergy and energy level

    International Nuclear Information System (INIS)

    Gao, Penghui; Dai, Yanjun; Tong, YenWah; Dong, Pengwei

    2015-01-01

    CCHP (combined cooling, heating and power) system as a poly-generation technology has received an increasing attention in field of small scale power systems for applications ranging from residence to utilities. It will also play an important role in waste to energy application for megacities. However, how to evaluate and manage energy utilization of CCHP scientifically remains unclear. In this paper, energy level and exergy analysis are implemented on energy conversion processes to reveal the variation of energy amount and quality in the operation of CCHP system. Moreover, based on the energy level analysis, the methodology of energy matching and optimization for the CCHP system is proposed. By this method, the operational parameters of CCHP system can be deduced to obtain an efficient performance and proper energy utilization. It will be beneficial to understand and operate the CCHP system, and to provide a guiding principle of the energy conversion and management for the CCHP system. - Highlights: • Energy level is implemented to reveal the energy variation of CCHP system. • A mathematical energy level analysis model of CCHP system is proposed. • By energy level analysis between supply and demand, optimal zone is obtained. • This study will be useful for energy matching and optimization of CCHP system

  7. The influence of dietary energy concentration and feed intake level ...

    African Journals Online (AJOL)

    for carcass gain (MJ ME/ g) improved with an increase in the C: R ratio. Steers fed sub-ad libitum feeding ... energie-inname vir karkastoename (MJ ME/ g) het verbeter met 'n toename in die K: R-verhouding. Doeltreffendheid van osse op die ... fic carbon sources on lipogenesis (Prior & Scott, 1980) have also been reported.

  8. Low-energy levels calculation for 193Ir

    International Nuclear Information System (INIS)

    Zahn, Guilherme Soares; Zamboni, Cibele Bugno; Genezini, Frederico Antonio; Mesa-Hormaza, Joel; Cruz, Manoel Tiago Freitas da

    2006-01-01

    In this work, a model based on single particle plus pairing residual interaction was used to study the low-lying excited states of the 193 Ir nucleus. In this model, the deformation parameters in equilibrium were obtained by minimizing the total energy calculated by the Strutinsky prescription; the macroscopic contribution to the potential was taken from the Liquid Droplet Model, with the shell and paring corrections used as as microscopic contributions. The nuclear shape was described using the Cassinian ovoids as base figures; the single particle energy spectra and wave functions for protons and neutrons were calculated in a deformed Woods-Saxon potential, where the parameters for neutrons were obtained from the literature and the parameters for protons were adjusted in order to describe the main sequence of angular momentum and parity of the band heads, as well as the proton binding energy of 193 Ir. The residual pairing interaction was calculated using the BCS prescription with Lipkin-Nogami approximation. The results obtained for the first three band heads (the 3/2 + ground state, the 1/2 + excited state at E ∼ 73 keV and the the 11/2 - isomeric state at E ∼ 80 keV) showed a very good agreement, but the model so far greatly overestimated the energy of the next band head, a 7/2 - at E ∼ 299 keV. (author)

  9. At what level of heat load are age-related impairments in the ability to dissipate heat evident in females?

    Directory of Open Access Journals (Sweden)

    Jill M Stapleton

    Full Text Available Studies have reported that older females have impaired heat loss responses during work in the heat compared to young females. However, it remains unclear at what level of heat stress these differences occur. Therefore, we examined whole-body heat loss [evaporative (HE and dry heat loss, via direct calorimetry] and changes in body heat storage (∆Hb, via direct and indirect calorimetry in 10 young (23±4 years and 10 older (58±5 years females matched for body surface area and aerobic fitness (VO2peak during three 30-min exercise bouts performed at incremental rates of metabolic heat production of 250 (Ex1, 325 (Ex2 and 400 (Ex3 W in the heat (40°C, 15% relative humidity. Exercise bouts were separated by 15 min of recovery. Since dry heat gain was similar between young and older females during exercise (p=0.52 and recovery (p=0.42, differences in whole-body heat loss were solely due to HE. Our results show that older females had a significantly lower HE at the end of Ex2 (young: 383±34 W; older: 343±39 W, p=0.04 and Ex3 (young: 437±36 W; older: 389±29 W, p=0.008, however no difference was measured at the end of Ex1 (p=0.24. Also, the magnitude of difference in the maximal level of HE achieved between the young and older females became greater with increasing heat loads (Ex1=10.2%, Ex2=11.6% and Ex3=12.4%. Furthermore, a significantly greater ∆Hb was measured for all heat loads for the older females (Ex1: 178±44 kJ; Ex2: 151±38 kJ; Ex3: 216±25 kJ, p=0.002 relative to the younger females (Ex1: 127±35 kJ; Ex2: 96±45 kJ; Ex3: 146±46 kJ. In contrast, no differences in HE or ∆Hb were observed during recovery (p>0.05. We show that older habitually active females have an impaired capacity to dissipate heat compared to young females during exercise-induced heat loads of ≥325 W when performed in the heat.

  10. Innovation in Multi-Level Governance for Energy Efficiency. Sharing experience with multi-level governance to enhance energy efficiency. Information paper

    Energy Technology Data Exchange (ETDEWEB)

    Jollands, Nigel; Gasc, Emilien; Pasquier, Sara Bryan

    2009-12-15

    Despite creating a plethora of national and international regulations and voluntary programmes to improve energy efficiency, countries are far from achieving full energy efficiency potential across all sectors of the economy. One major challenge, among numerous barriers, is policy implementation. One strategy that many national governments and international organisations have used to address the implementation issue is to engage regional and local authorities. To that end, many programmes have been created that foster energy efficiency action and collaboration across levels of government. The aim of this report is to identify trends and detail recent developments in multi-level governance in energy efficiency (MLGEE). By sharing lessons learned from daily practitioners in the field, the IEA hopes energy efficiency policy makers at all levels of government will be able to identify useful multilevel governance (MLG) practices across geographical and political contexts and use these to design robust programmes; modify existing programmes, and connect and share experiences with other policy makers in this field.

  11. Rice (Oryza sativa japonica) Albumin Suppresses the Elevation of Blood Glucose and Plasma Insulin Levels after Oral Glucose Loading.

    Science.gov (United States)

    Ina, Shigenobu; Ninomiya, Kazumi; Mogi, Takashi; Hase, Ayumu; Ando, Toshiki; Matsukaze, Narumi; Ogihara, Jun; Akao, Makoto; Kumagai, Hitoshi; Kumagai, Hitomi

    2016-06-22

    The suppressive effect of rice albumin (RA) of 16 kDa on elevation of blood glucose level after oral loading of starch or glucose and its possible mechanism were examined. RA suppressed the increase in blood glucose levels in both the oral starch tolerance test and the oral glucose tolerance test. The blood glucose concentrations 15 min after the oral administration of starch were 144 ± 6 mg/dL for control group and 127 ± 4 mg/dL for RA 200 mg/kg BW group, while those after the oral administration of glucose were 157 ± 7 mg/dL for control group and 137 ± 4 mg/dL for RA 200 mg/kg BW group. However, in the intraperitoneal glucose tolerance test, no significant differences in blood glucose level were observed between RA and the control groups, indicating that RA suppresses the glucose absorption from the small intestine. However, RA did not inhibit the activity of mammalian α-amylase. RA was hydrolyzed to an indigestible high-molecular-weight peptide (HMP) of 14 kDa and low-molecular-weight peptides by pepsin and pancreatin. Furthermore, RA suppressed the glucose diffusion rate through a semipermeable membrane like dietary fibers in vitro. Therefore, the indigestible HMP may adsorb glucose and suppress its absorption from the small intestine.

  12. Effect of footwear on muscular loading and energy demand during distance running

    DEFF Research Database (Denmark)

    Ketabi, Shahin

    an obvious choice of modulating loading and with that running economy, performance and potentially overuse injuries. The muscular activations prior to touch-down are varied in response to changes in shoe construction, referred to as muscle tuning, possibly keeping the impact magnitude at an individually......The most popular activity around the world which involves the conversion of muscular forces into translocation through complex reciprocal movement patterns is running. Running economy is an important element of performance in distance running. A number of biomechanical parameters have been related...... to running economy and performance. Association of running mechanics with metabolic processes and economy is not well understood and very complex. Footwear is typically a controlled variable with several design features which may influence economical running. Modifications to running shoes can be considered...

  13. Experimental verificatio of load resistance switching for global stabilization of high-energy response of a nonlinear wideband electromagnetic vibration energy harvester

    International Nuclear Information System (INIS)

    Sato, T; Masuda, A; Sanada, T

    2015-01-01

    This paper presents an experimental verification of a self-excitation control of a resonance- type vibration energy harvester with a Duffing-type nonlinearity which is designed to perform effectively in a wide frequency range. For the conventional linear vibration energy harvester, the performance of the power generation at the resonance frequency and the bandwidth of the resonance peak are trade-off. The resonance frequency band can be expanded by introducing a Duffing-type nonlinear oscillator in order to enable the harvester to generate larger electric power in a wider frequency range. However, since such nonlinear oscillator can have multiple stable steady-state solutions in the resonance band, it is difficult for the nonlinear harvester to maintain the high performance of the power generation constantly. The principle of self-excitation and entrainment has been utilized to provide the global stability to the highest-energy solution by destabilizing other unexpected lower-energy solutions by introducing a switching circuit of the load resistance between positive and the negative values depending on the response amplitude of the oscillator. It has been experimentally validated that this control law imparts the self-excitation capability to the oscillator to show an entrainment into the highest-energy solution. (paper)

  14. Numerical modeling of sandwich panel response to ballistic loading - energy balance for varying impactor geometries

    DEFF Research Database (Denmark)

    Kepler, Jørgen Asbøl; Hansen, Michael Rygaard

    2007-01-01

    thickness but significantly smaller than panel length dimensions. Experimental data for the total loss in impactor kinetic energy and momentum and estimated damage energy are described. For a selection of impactor tip shapes, the numerical model is used to evaluate different simplified force histories...... between the impactor and the panel during penetration. The force histories are selected from a primary criterion of conservation of linear momentum in the impactor-panel system, and evaluated according to agreement with the total measured energy balance.......A sandwich panel is described by an axisymmetric lumped mass- spring model. The panel compliance is simplified, considering only core shear deformation uniformly distributed across the core thickness. Transverse penetrating impact is modeled for impactors of diameters comparable to the panel...

  15. Effect of dietary protein and energy levels on the growth ...

    African Journals Online (AJOL)

    Dr. A.O. Ani

    While there were significant interactions (P< 0.05) between TBNO and enzyme levels on DM, ... ingredients like soya bean meal, groundnut meal, etc vis- à-vis their acute ... bacterial infection and sulfaquinoxaline drugs against coccidioses.

  16. The influence of dietary energy concentration and feed intake level ...

    African Journals Online (AJOL)

    feed intake levels on digestibility, feed intake, growth, feed efficiency and .... phosphorus and crude protein (N X 6.25) according to the methods of the .... supported by a parallel relationship between the ME content of .... dilution by saliva.

  17. Effects of varying dietary zinc levels on energy and nitrogen ...

    African Journals Online (AJOL)

    Parameters determined were dry matter intake (DMI), energy utilization and nitrogen utilization. The mean±SE of Panicum maximum, Andropogon gayanus, Pennisetum purpureum, Leucaena leucocephala and Gliricidia sepium, contained 31.2±5.0; 29.1± 3.0;34.6± 6.0; 45.0± 5.0 and 47.1± 4.0mg Zn/kg DM respectively.

  18. Local electricity market design for the coordination of distributed energy resources at district level

    NARCIS (Netherlands)

    Ampatzis, M.; Nguyen, P.H.; Kling, W.L.

    2014-01-01

    The increasing penetration of distributed energy resources at the distribution grid level creates concerns about their successful integration in the existing electric grid, designed for centralized generation by large power plants. Failure to the proper integration of distributed energy resources

  19. Detailed partial load investigation of a thermal energy storage concept for solar thermal power plants with direct steam generation

    Science.gov (United States)

    Seitz, M.; Hübner, S.; Johnson, M.

    2016-05-01

    Direct steam generation enables the implementation of a higher steam temperature for parabolic trough concentrated solar power plants. This leads to much better cycle efficiencies and lower electricity generating costs. For a flexible and more economic operation of such a power plant, it is necessary to develop thermal energy storage systems for the extension of the production time of the power plant. In the case of steam as the heat transfer fluid, it is important to use a storage material that uses latent heat for the storage process. This leads to a minimum of exergy losses during the storage process. In the case of a concentrating solar power plant, superheated steam is needed during the discharging process. This steam cannot be superheated by the latent heat storage system. Therefore, a sensible molten salt storage system is used for this task. In contrast to the state-of-the-art thermal energy storages within the concentrating solar power area of application, a storage system for a direct steam generation plant consists of a latent and a sensible storage part. Thus far, no partial load behaviors of sensible and latent heat storage systems have been analyzed in detail. In this work, an optimized fin structure was developed in order to minimize the costs of the latent heat storage. A complete system simulation of the power plant process, including the solar field, power block and sensible and latent heat energy storage calculates the interaction between the solar field, the power block and the thermal energy storage system.

  20. Multi-Class load balancing scheme for QoS and energy ...

    African Journals Online (AJOL)

    The challenges of adhering to stringent Quality of Service requirements, efficiently utilize resources, and conserve energy consumption are constantly being faced by Cloud Service Providers. In a bid to proffer solutions to these challenges, numerous researchers have proposed varied solutions. However, there has yet to be ...