WorldWideScience

Sample records for load lbs c055

  1. An Efficient and Privacy-Preserving Multiuser Cloud-Based LBS Query Scheme

    Directory of Open Access Journals (Sweden)

    Lu Ou

    2018-01-01

    Full Text Available Location-based services (LBSs are increasingly popular in today’s society. People reveal their location information to LBS providers to obtain personalized services such as map directions, restaurant recommendations, and taxi reservations. Usually, LBS providers offer user privacy protection statement to assure users that their private location information would not be given away. However, many LBSs run on third-party cloud infrastructures. It is challenging to guarantee user location privacy against curious cloud operators while still permitting users to query their own location information data. In this paper, we propose an efficient privacy-preserving cloud-based LBS query scheme for the multiuser setting. We encrypt LBS data and LBS queries with a hybrid encryption mechanism, which can efficiently implement privacy-preserving search over encrypted LBS data and is very suitable for the multiuser setting with secure and effective user enrollment and user revocation. This paper contains security analysis and performance experiments to demonstrate the privacy-preserving properties and efficiency of our proposed scheme.

  2. A Hybrid Smartphone Indoor Positioning Solution for Mobile LBS

    OpenAIRE

    Liu, Jingbin; Chen, Ruizhi; Pei, Ling; Guinness, Robert; Kuusniemi, Heidi

    2012-01-01

    Smartphone positioning is an enabling technology used to create new business in the navigation and mobile location-based services (LBS) industries. This paper presents a smartphone indoor positioning engine named HIPE that can be easily integrated with mobile LBS. HIPE is a hybrid solution that fuses measurements of smartphone sensors with wireless signals. The smartphone sensors are used to measure the user’s motion dynamics information (MDI), which represent the spatial correlatio...

  3. Perceptions of preparedness of LBS I teachers in the state of Illinois and graduates of Illinois State University's LBS I program to collaborate in teaching grade 7--12 math, science, and social science

    Science.gov (United States)

    Caldwell, Janet E.

    The expectations for no child to be left behind are leading to increased emphasis on teaching math, science, and social science effectively to students with disabilities. This study utilized information collected from online surveys to examine how current LBS I teachers and individuals graduating from the Illinois State University teacher certification program in LBS I perceive their preparedness to teach these subjects. Participants provided information about coursework and life experiences, and they made suggestions about teacher preparation and professional development programs. Six key items forming the composite variable focused on level of preparation in (a) best practices, (b) selecting materials, (c) selecting objectives, (d) adapting instructional strategies, (e) planning lessons, and (f) and evaluating outcomes. Only 30 LBS I teachers of the 282 contacted by e-mail completed surveys. Of 115 graduates contacted, 71 participated in the original survey and 23 participated in a follow-up survey. Data were analyzed to learn more about the teachers' self-perceptions regarding preparedness to teach math, science, or social science. There was a correlation between perceived level of knowledge and the composite preparation variable for all subjects, but no correlation with length of teaching. Both groups indicated high school content courses were important in preparation to teach. Teachers also indicated collaboration and graduates indicated grade school learning. The most frequent recommendation for both teacher preparation and professional development was additional methods courses. A survey distributed to math, science, and social science teachers of Grades 7--12 asked about their perceptions of the preparedness of LBS I teachers to teach their area of content. Few surveys were completed for each subject so they were examined qualitatively. There was variability among participants, but generally the content area teachers rated themselves as more prepared than

  4. The New Fundamentals Of Marketing | Smith | LBS Management ...

    African Journals Online (AJOL)

    Topics addressed include: marketing and brand metrics, launching of a new brand, the evolving role ... creation of customer loyalty and/or commitment, customer intelligence, and positioning. ... LBS Management Review Vol.8(1) 2003: 28-55 ...

  5. Draft Genome Sequence of Lactobacillus casei Lbs2.

    Science.gov (United States)

    Bhowmick, Swati; Malar, Mathu; Das, Abhishek; Kumar Thakur, Bhupesh; Saha, Piu; Das, Santasabuj; Rashmi, H M; Batish, Virender K; Grover, Sunita; Tripathy, Sucheta

    2014-12-24

    We report here a 3.2-Mb draft assembled genome of Lactobacillus casei Lbs2. The bacterium shows probiotic and immunomodulatory activities. The genome assembly and annotation will help to identify molecules and pathways responsible for interaction between the host immune system and the microbe. Copyright © 2014 Bhowmick et al.

  6. How to Reduce Corruption | Collier | LBS Management Review

    African Journals Online (AJOL)

    No Abstract Available LBS Management Review Vol.4(2) 1999: 135-147. Full Text: EMAIL FULL TEXT EMAIL FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT · http://dx.doi.org/10.4314/lbsmr.v4i2.24462 · AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors ...

  7. Book Review: Building the Team by Chantal Epie | Ovadje | LBS ...

    African Journals Online (AJOL)

    LBS Management Review. Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives · Journal Home > Vol 9, No 1 (2004) >. Log in or Register to get access to full text downloads.

  8. A Generic Framework for Location-Based Services (LBS Provisioning

    Directory of Open Access Journals (Sweden)

    Ioannis Priggouris

    2006-01-01

    Full Text Available Location Based Services can be considered as one of the most rapidly expanding fields of the mobile communications sector, with an impressively large application range. The proliferation of mobile/wireless Internet and mobile computing, and the constantly increasing use of handheld, mobile devices and position tracking technologies prepared the grounds for the introduction of this new type of services. The combination of position fixing mechanisms with location-dependent, geographical information, can offer truly customized personal communication services through the mobile phone or other type of devices. Prompted by the avalanche of technology advances in the aforementioned areas in this paper we present an integrated platform for delivering Location Based Services (LBS. The platform covers the full life cycle of a LBS starting from the specification of the service, covering issues like the deployment and maintenance of services, the service invocation and the final delivery of the produced results to the invoking user. A prototype implementation of the discussed platform was developed and used to perform a series of trial services, with the purpose of demonstrating the pursued functionality.

  9. Study of LBS for characterization and analysis of big data benchmarks

    International Nuclear Information System (INIS)

    Chandio, A.A.; Zhang, F.; Memon, T.D.

    2014-01-01

    In the past few years, most organizations are gradually diverting their applications and services to Cloud. This is because Cloud paradigm enables (a) on-demand accessed and (b) large data processing for their applications and users on Internet anywhere in the world. The rapid growth of urbanization in developed and developing countries leads a new emerging concept called Urban Computing, one of the application domains that is rapidly deployed to the Cloud. More precisely, in the concept of Urban Computing, sensors, vehicles, devices, buildings, and roads are used as a component to probe city dynamics. Their data representation is widely available including GPS traces of vehicles. However, their applications are more towards data processing and storage hungry, which is due to their data increment in large volume starts from few dozen of TB (Tera Bytes) to thousands of PT (Peta Bytes) (i.e. Big Data). To increase the development and the assessment of the applications such as LBS (Location Based Services), a benchmark of Big Data is urgently needed. This research is a novel research on LBS to characterize and analyze the Big Data benchmarks. We focused on map-matching, which is being used as pre-processing step in many LBS applications. In this preliminary work, this paper also describes current status of Big Data benchmarks and our future direction. (author)

  10. Study on LBS for Characterization and Analysis of Big Data Benchmarks

    Directory of Open Access Journals (Sweden)

    Aftab Ahmed Chandio

    2014-10-01

    Full Text Available In the past few years, most organizations are gradually diverting their applications and services to Cloud. This is because Cloud paradigm enables (a on-demand accessed and (b large data processing for their applications and users on Internet anywhere in the world. The rapid growth of urbanization in developed and developing countries leads a new emerging concept called Urban Computing, one of the application domains that is rapidly deployed to the Cloud. More precisely, in the concept of Urban Computing, sensors, vehicles, devices, buildings, and roads are used as a component to probe city dynamics. Their data representation is widely available including GPS traces of vehicles. However, their applications are more towards data processing and storage hungry, which is due to their data increment in large volume starts from few dozen of TB (Tera Bytes to thousands of PT (Peta Bytes (i.e. Big Data. To increase the development and the assessment of the applications such as LBS (Location Based Services, a benchmark of Big Data is urgently needed. This research is a novel research on LBS to characterize and analyze the Big Data benchmarks. We focused on map-matching, which is being used as pre-processing step in many LBS applications. In this preliminary work, this paper also describes current status of Big Data benchmarks and our future direction

  11. Marketing Tool Kit for Nigeria: A Preview | Smith | LBS Management ...

    African Journals Online (AJOL)

    No Abstract Available LBS Management Review Vol.5(2) 2000: 113-129. Full Text: EMAIL FULL TEXT EMAIL FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT · http://dx.doi.org/10.4314/lbsmr.v5i2.24452 · AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors ...

  12. A Hybrid Smartphone Indoor Positioning Solution for Mobile LBS

    Directory of Open Access Journals (Sweden)

    Heidi Kuusniemi

    2012-12-01

    Full Text Available Smartphone positioning is an enabling technology used to create new business in the navigation and mobile location-based services (LBS industries. This paper presents a smartphone indoor positioning engine named HIPE that can be easily integrated with mobile LBS. HIPE is a hybrid solution that fuses measurements of smartphone sensors with wireless signals. The smartphone sensors are used to measure the user’s motion dynamics information (MDI, which represent the spatial correlation of various locations. Two algorithms based on hidden Markov model (HMM problems, the grid-based filter and the Viterbi algorithm, are used in this paper as the central processor for data fusion to resolve the position estimates, and these algorithms are applicable for different applications, e.g., real-time navigation and location tracking, respectively. HIPE is more widely applicable for various motion scenarios than solutions proposed in previous studies because it uses no deterministic motion models, which have been commonly used in previous works. The experimental results showed that HIPE can provide adequate positioning accuracy and robustness for different scenarios of MDI combinations. HIPE is a cost-efficient solution, and it can work flexibly with different smartphone platforms, which may have different types of sensors available for the measurement of MDI data. The reliability of the positioning solution was found to increase with increasing precision of the MDI data.

  13. A hybrid smartphone indoor positioning solution for mobile LBS.

    Science.gov (United States)

    Liu, Jingbin; Chen, Ruizhi; Pei, Ling; Guinness, Robert; Kuusniemi, Heidi

    2012-12-12

    Smartphone positioning is an enabling technology used to create new business in the navigation and mobile location-based services (LBS) industries. This paper presents a smartphone indoor positioning engine named HIPE that can be easily integrated with mobile LBS. HIPE is a hybrid solution that fuses measurements of smartphone sensors with wireless signals. The smartphone sensors are used to measure the user's motion dynamics information (MDI), which represent the spatial correlation of various locations. Two algorithms based on hidden Markov model (HMM) problems, the grid-based filter and the Viterbi algorithm, are used in this paper as the central processor for data fusion to resolve the position estimates, and these algorithms are applicable for different applications, e.g., real-time navigation and location tracking, respectively. HIPE is more widely applicable for various motion scenarios than solutions proposed in previous studies because it uses no deterministic motion models, which have been commonly used in previous works. The experimental results showed that HIPE can provide adequate positioning accuracy and robustness for different scenarios of MDI combinations. HIPE is a cost-efficient solution, and it can work flexibly with different smartphone platforms, which may have different types of sensors available for the measurement of MDI data. The reliability of the positioning solution was found to increase with increasing precision of the MDI data.

  14. IAEA TECDOC 055 Outline

    Energy Technology Data Exchange (ETDEWEB)

    Shull, Doug [Gregg Protection Services, Palm Beach Gardens, FL (United States)

    2015-07-13

    An outline of suggestions for updating a version of IAEA-TECDOC-1276 is provided. This update will become IAEA-TECDOC-055, titled ''IAEA handbook for designing and implementing physical protection systems for nuclear material and nuclear facilities.''

  15. What’s Around Me?: Applying the Theory of Consumption Values to Understanding the Use of Location-Based Services (LBS) on Smart Phones

    OpenAIRE

    Jing Zhang; En Mao

    2012-01-01

    Businesses are increasingly aware of the power of mobile location-based services (LBS) in their success. For consumers, there are abundant options available. To understand the driving factors of consumers’ behavioral intention to use LBS and speak positively about LBS, a model of examining personal values and their influences was developed in this study. The model centers around a set of consumers’ personal consumption values (Sheth et al., 1991a, 1991b), including functional values exemp...

  16. 46 CFR 160.055-1 - Incorporation by reference.

    Science.gov (United States)

    2010-10-01

    ...: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Life Preservers, Unicellular Plastic Foam, Adult and Child, for... Resistance of Plastic Film and Sheeting—160.055-3 (5) Coast Guard specification: 164.015—Plastic Foam.... 160.055-IA: Sheet 1—Construction and Arrangement, Vinyl Dip Coated, Model 62, Adult. Sheet 2...

  17. LBS Mobile Learning System Based on Android Platform

    Directory of Open Access Journals (Sweden)

    Zhang Ya-Li

    2017-01-01

    Full Text Available In the era of mobile internet, PC-end internet services can no long satisfy people’s demands, needs for App and services on mobile phones are more urgent than ever. With increasing social competition, the concept of lifelong learning becomes more and more popular and accepted, making full use of spare time to learn at any time and any place meets updating knowledge desires of modern people, Location Based System (LBS mobile learning system based on Android platform was created under such background. In this Paper, characteristics of mobile location technology and intelligent terminal were introduced and analyzed, mobile learning system which will fulfill personalized needs of mobile learners was designed and developed on basis of location information, mobile learning can be greatly promoted and new research ideas can be expanded for mobile learning.

  18. India's first 100,000 lbs/hr atmospheric bed boiler

    International Nuclear Information System (INIS)

    Mahajan, S.K.

    1991-01-01

    This paper covers the operating experience at the Petrochemical Complex of Hindustan Polymers, a Member Company of the UB Group, India, on the India's first 100,000 Lbs/hr atmospheric fluidized bed boiler supplied by Bharat Heavy Electricals Ltd., India. This atmospheric fluidized bed boiler is in operation for over 7 years with over 51,000 operating hours. The paper covers the details of onstream hours, actual thermal efficiency achieved, type of coal used and operational advantages of such boilers as per experience of Hindustan Polymers. Paper also highlights the maintenance and equipment problems as well as the developments which have taken place to overcome such problems. Details of experience in the operation of this boiler with baghouse system using abrasive and high ash coal are also covered

  19. LOADING SIMULATION PROGRAM C

    Data.gov (United States)

    U.S. Environmental Protection Agency — LSPC is the Loading Simulation Program in C++, a watershed modeling system that includes streamlined Hydrologic Simulation Program Fortran (HSPF) algorithms for...

  20. LOADING SIMULATION PROGRAM C

    Science.gov (United States)

    LSPC is the Loading Simulation Program in C++, a watershed modeling system that includes streamlined Hydrologic Simulation Program Fortran (HSPF) algorithms for simulating hydrology, sediment, and general water quality

  1. A comparative genomics approach to find out the probiotic effects of Lactobacillus casei Lbs2 isolated from healthy gut of Indian population

    Directory of Open Access Journals (Sweden)

    Samrat Ghosh

    2017-10-01

    Full Text Available Lactobacillae are gram positive diverse group of species and have association with nutrient rich niches like humans, animals and plants. Lactobacillus casei is considered as one of the most competent probiotic throughout the world. Its microbiological feature historically well-established but genomic analysis including comparative genomics is recent. Lactobacillus casei Lbs2 strain was isolated from the gut of a healthy north Indian individual and sequenced. We compared the genomes of Lactobacillus casei Lbs2 with 8 other complete genomes of the same species e.g.;  LC2W, BL23, BDII, W56, 12A, Zhang, LOCK919, ATCC393 using BRIG (Blast Ring Image Generator, Gene enrichment analysis using Fischer Extract test in R. Lbs2 strain has a number of genes including bile tolerance, stress response re-iterating its probiotic stand. Interestingly, genes coding for transposons, co-enzyme transport and metabolisms are enriched in the Indian Genome. Presence of large number of transposons indicates this genome is undergoing expansion and under adaptive selection pressure. When we compared our genome based on Multilocus Sequence Typing (rMLST, we found this strain is closely similar to Lactobacillus fermentum rather than other L. casei strains. Comparison of Lbs2 strain with other L. casei strains indicates ATCC393 (isolated from daily product is closer than others.

  2. Ubiquitous User Localization in LBS - The Need for Implementing Ethical Thinking in Our Research Field

    Science.gov (United States)

    Retscher, Guenther; Obex, Franz

    2015-12-01

    Location-based Services (LBS) influence nowadays every individual's life due to the emerging market penetration of smartphones and other mobile devices. For smartphone Apps localization technologies are developed ranging from GNSS beyond to other alternative ubiquitous positioning methods as well as the use of the in-built inertial sensors, such as accelerometers, gyroscopes, magnetometer, barometer, etc. Moreover, signals-of-opportunity which are not intended for positioning at the first sight but are receivable in many environments such as in buildings and public spaces are more and more utilized for positioning and navigation. The use of Wi-Fi (Wireless Fidelity) is a typical example. These technologies, however, have become very powerful tools as the enable to track an individual or even a group of users. Most technical researchers imply that it is mainly about further enhancing technologies and algorithms including the development of new advanced Apps to improve personal navigation and to deliver location oriented information just in time to a single LBS user or group of users. The authors claim that there is a need that ethical and political issues have to be addressed within our research community from the very beginning. Although there is a lot of research going on in developing algorithms to keep ones data and LBS search request in private, researchers can no longer keep their credibility without cooperating with ethical experts or an ethical committee. In a study called InKoPoMoVer (Cooperative Positioning for Real-time User Assistance and Guidance at Multi-modal Public Transit Junctions) a cooperation with social scientists was initiated for the first time at the Vienna University of Technology, Austria, in this context. The major aims of this study in relation to ethical questions are addressed in this paper.

  3. Low-back electromyography (EMG data-driven load classification for dynamic lifting tasks.

    Directory of Open Access Journals (Sweden)

    Deema Totah

    Full Text Available Numerous devices have been designed to support the back during lifting tasks. To improve the utility of such devices, this research explores the use of preparatory muscle activity to classify muscle loading and initiate appropriate device activation. The goal of this study was to determine the earliest time window that enabled accurate load classification during a dynamic lifting task.Nine subjects performed thirty symmetrical lifts, split evenly across three weight conditions (no-weight, 10-lbs and 24-lbs, while low-back muscle activity data was collected. Seven descriptive statistics features were extracted from 100 ms windows of data. A multinomial logistic regression (MLR classifier was trained and tested, employing leave-one subject out cross-validation, to classify lifted load values. Dimensionality reduction was achieved through feature cross-correlation analysis and greedy feedforward selection. The time of full load support by the subject was defined as load-onset.Regions of highest average classification accuracy started at 200 ms before until 200 ms after load-onset with average accuracies ranging from 80% (±10% to 81% (±7%. The average recall for each class ranged from 69-92%.These inter-subject classification results indicate that preparatory muscle activity can be leveraged to identify the intent to lift a weight up to 100 ms prior to load-onset. The high accuracies shown indicate the potential to utilize intent classification for assistive device applications.Active assistive devices, e.g. exoskeletons, could prevent back injury by off-loading low-back muscles. Early intent classification allows more time for actuators to respond and integrate seamlessly with the user.

  4. An Effective Privacy Architecture to Preserve User Trajectories in Reward-Based LBS Applications

    Directory of Open Access Journals (Sweden)

    A S M Touhidul Hasan

    2018-02-01

    Full Text Available How can training performance data (e.g., running or walking routes be collected, measured, and published in a mobile program while preserving user privacy? This question is becoming important in the context of the growing use of reward-based location-based service (LBS applications, which aim to promote employee training activities and to share such data with insurance companies in order to reduce the healthcare insurance costs of an organization. One of the main concerns of such applications is the privacy of user trajectories, because the applications normally collect user locations over time with identities. The leak of the identified trajectories often results in personal privacy breaches. For instance, a trajectory would expose user interest in places and behaviors in time by inference and linking attacks. This information can be used for spam advertisements or individual-based assaults. To the best of our knowledge, no existing studies can be directly applied to solve the problem while keeping data utility. In this paper, we identify the personal privacy problem in a reward-based LBS application and propose privacy architecture with a bounded perturbation technique to protect user’s trajectory from the privacy breaches. Bounded perturbation uses global location set (GLS to anonymize the trajectory data. In addition, the bounded perturbation will not generate any visiting points that are not possible to visit in real time. The experimental results on real-world datasets demonstrate that the proposed bounded perturbation can effectively anonymize location information while preserving data utility compared to the existing methods.

  5. Live and heat-killed probiotic Lactobacillus casei Lbs2 protects from experimental colitis through Toll-like receptor 2-dependent induction of T-regulatory response.

    Science.gov (United States)

    Thakur, Bhupesh Kumar; Saha, Piu; Banik, George; Saha, Dhira Rani; Grover, Sunita; Batish, Virender Kumar; Das, Santasabuj

    2016-07-01

    Inflammatory bowel disease (IBD) is a group of inflammatory disorders of the intestine caused by dysregulated T-cell mediated immune response against commensal microflora. Probiotics are reported as therapeutically effective against IBD. However, variable efficacy of the live probiotic strains, difference in survival and persistence in the gut between the strains and the lack of insight into the mechanisms of probiotic action limit optimal therapeutic efficacy. Our aims were to evaluate the lactobacillus strains isolated from the North Indian population for the generation of regulatory cells and cytokines in the intestine, to study their effects on pro-inflammatory mediators in the mouse model of inflammatory bowel disease and to explore the underlying mechanisms of their actions. Among the selected lactobacillus strains, Lactobacillus casei Lbs2 (MTCC5953) significantly suppressed lipopolysaccharide-induced pro-inflammatory cytokine (TNF-alpha, IL-6) secretion. Both live and heat-killed Lbs2 polarized Th0 cells to T-regulatory (Treg) cells in vitro, increased the frequency of FoxP3(+) Treg cells in the mesenteric lymph nodes (MLNs) and alleviated macroscopic and histopathological features of colitis in probiotic-fed mice. Moreover, the levels of IL-12, TNF-alpha and IL-17A were suppressed, while IL-10 and TGF-beta levels were augmented in the colonic tissues of Lbs2-treated mice. The induced Treg (iTreg) cells secreted IL-10 and TGF-beta and exerted suppressive effects on the proliferation of effector T-cells. Adoptive transfer of iTreg cells ameliorated the disease manifestations of murine colitis and suppressed the levels of TNF-alpha and IL-17A. Finally, Lbs2 effects were mediated by Toll-like receptor 2 (TLR2) activation on the dendritic cells. This study identified live and heat-killed Lbs2 as putative therapeutic candidates against IBD and highlighted their Toll-like receptor 2-dependent immunomodulatory and regulatory function. Copyright © 2016 Elsevier B

  6. Development of a load cell for mechanical testing in hydrogen

    International Nuclear Information System (INIS)

    McCabe, L.P.

    1982-01-01

    Mechanical testing in hydrogen environments is performed on materials to determine hydrogen compatibility. Many tests are performed on small test samples in pressure vessels where monitoring of actual sample load is difficult. A method was developed to monitor small samples by placing inside the vessel a miniature load cell which is capable of measuring loads of less than 100 lbs. The load cell monitors load by means of a Wheatstone Bridge circuit composed of four strain gages. Two of the gages are mounted on a stainless steel stub which becomes part of the vessel load string; the others are wired outside the pressure vessel. Previously, load cells have been short-lived because of hydrogen diffusion into the epoxy-phenolic adhesive used to attach the strain gages to the stub. The use of a flame-sprayed ceramic, however, rather than an organic epoxy to mount the strain gages appears to produce a load cell resistant to the hydrogen test environment

  7. Spot volume exceeds 2 million lbs (again); restricted price hits $10/lb

    International Nuclear Information System (INIS)

    Anon.

    1995-01-01

    This article is the January 1995 uranium market summary. Volume on the spot concentrates market exceeded 2 million lbs equivalent for the second consecutive month. Six deals took place; four in the spot concentrates market, one in the conversion market, and one in the enrichment market. No deals took place in the medium or long-term market. The upper end of the restricted price range reached $10.00 per lb U3O8, its highest level since December 1993. The lower end of the restricted price range strengthened to $9.75. The lower end of the spot conversion price range strengthed to $5.70 per kg U, and SWU prices firmed to the $75.00 to $87.00 level

  8. Influence of applied load on wear behavior of C/C-Cu composites under electric current

    Directory of Open Access Journals (Sweden)

    Jian Yin

    2017-04-01

    Full Text Available Using carbon fiber needled fabrics with Cu-mesh and graphite powder as the preform, Cu mesh modified carbon/carbon(C/C-Cu composites were prepared by chemical vapor deposition (CVD with C3H6 and impregnation-carbonization (I/C with furan resin. C/C composites, as a comparison, were also prepared. Their microstructures and wear morphologies were observed by optical microscopy (OM and scanning electron microscope (SEM, respectively. Wear behavior of C/C and C/C-Cu composites under different applied loads were investigated on a pin-on-disc wear tester. The results show that Cu meshes are well dispersed and pyrolytic carbon is in rough laminar structure. Both C/C and C/C-Cu composites had good wear properties. The current-carrying capacity of C/C-Cu composites increases and the arc discharge is hindered as the applied load increases from 40 N to 80 N. Both C/C and C/C-Cu composites had good wear properties. The mass wear rate of C/C-Cu composites under 80 N was only 4.2% of that under 60 N. In addition, C/C-Cu composites represent different wear behaviors because wear mechanisms of arc erosion, abrasive wear, adhesive wear, and oxidative wear are changing under different applied loads.

  9. Tissue viral load variability in chronic hepatitis C.

    LENUS (Irish Health Repository)

    Fanning, L

    2012-02-03

    OBJECTIVE: Liver biopsy is regarded as the gold standard for assessing disease activity in chronic hepatitis C, but sampling error is a potential limitation. Whether sampling variability applies equally to viral load assessment as it does to histology is uncertain. To examine this, we compared viral load between right- and left-lobe biopsy specimens from patients infected with hepatitis C virus (HCV). METHODS: Bilobe biopsies were taken from 16 patients who were serum positive for HCV RNA by reverse transcription-polymerase chain reaction. Genotype was identified by reverse line probe hybridization. There was an absence of competing risk factors for infectious and other liver diseases in this patient group. Histology and hepatic viral load were assessed blindly. None of the patients had received antiviral therapy at the time of study. RESULTS: Detection of HCV in right and left lobes was concordant with serum positivity in all cases. The viral load between lobes was highly correlated (p = 0.0003, r = 0.79). In contrast, the histological activity indices of inflammation and fibrosis\\/cirrhosis were poorly correlated between lobes (p = 0.038, r = 0.60, and p = 0.098, r = 0.50, respectively). CONCLUSION: Hepatic viral load variability does not suffer from the same degree of heterogeneity of sampling variability as does histology.

  10. Metal Top Adapter ACV0000807, Manufactured by Delfasco, Inc. for Alliant Techsystems, Inc., for PA116 Containers on a 44" x 40" Wood Pallet, First Article Tests (FATs) IAW MIL-STD-1660, "Design Criteria for Ammunition Unit Loads"

    National Research Council Canada - National Science Library

    Dugan, Jeffery L

    2008-01-01

    ...) test units were tested with a load of 2,495 lbs each. The tests accomplished on the test units were the Stacking, Repetitive Shock, Drop, Incline-Impact, Sling Compatibility, Forklifting, and Disassembly Tests...

  11. Engineering Evaluation Tests of 16 Gauge vs 14 Gauge Staples IAW MIL-STD-1660, 40MM Cartridge on Wooden Pallet

    National Research Council Canada - National Science Library

    Dugan, Jeffery L

    2008-01-01

    .... Three test units were tested with a load of 2,290 lbs, 2,295 lbs, and 2,295 lbs. The testing accomplished on the test units was the Stacking, Repetitive Shock, Drop, Incline-Impact, Forklifting, and Disassembly Tests. Test Units #1...

  12. Qualification Testing for Clipless Seal Used on 3/4 Banding, 40 in. x 48 in. Wood Pallet With .50 Caliber Ammunition in M2 Metal Boxes in Wire Bound Boxes IAW MIL-STD-1660, "Design Criteria for Ammunition Unit Loads"

    National Research Council Canada - National Science Library

    2006-01-01

    ...), from Independence, Missouri. Two test units were tested with a load of 4,200 lbs. each. The tests accomplished on the test units were the stacking, vibration, drop, incline impact, forklift handling, and disassembly tests...

  13. 78 FR 38826 - Airworthiness Directives; Various Helicopter Models

    Science.gov (United States)

    2013-06-28

    ... (ECD) Model MBB-BK 117 C-2 helicopter picked up a dummy load of 552 lbs. to conduct a ``maximum load... comply with this AD. It will take about 1 work-hour to perform the lift testing at an average labor rate... the distribution of power and responsibilities among the various levels of government. For the reasons...

  14. Acceptance test procedure, 241-SY-101/241-C-106 shot loading system

    International Nuclear Information System (INIS)

    Ostrom, M.J.

    1994-01-01

    This Acceptance Test Procedure is for the 241-SY-101/241-C-106 Shot Loading System. The procedure will test the components of the Shot Loading System and its capability of adequately loading shot into the annular space of the Container. The loaded shot will provide shielding as required for transporting and storage of a contaminated pump after removal from the tank. This test serves as verification that the SLS is acceptable for use in the pump removal operations for Tanks 241-SY-101, 241-C-106 and 241-AY-102. The pump removal operation for these three tanks will be performed by two different organizations with different equipment, but the Shot Loading System will be compatible between the two operations

  15. High heat load properties of TiC dispersed Mo alloys

    International Nuclear Information System (INIS)

    Tokunaga, Kazutoshi; Yoshida, Naoaki; Miura, Yasushi; Kurishita, Hiroaki; Kitsunai, Yuji; Kayano, Hideo.

    1996-01-01

    Electron beam high heat load experiment of new developed three kinds of TiC dispersed Mo alloys (Mo-0.1wt%TiC, Mo-0.5wt%TiC and Mo-1.0wt%TiC) was studied so as to evaluate it's high heat load at using as the surface materials of divertor. The obtained results indicated that cracks were not observed by embrittlement by recrystallization until about 2200degC of surface temperature and the gas emission properties were not different from sintered molibdenum. However, at near melting point, deep cracks on grain boundary and smaller gas emission than that of sintered Mo were observed. So that, we concluded that TiC dispersed Mo alloy was good surface materials used under the conditions of the stationary heat flux and less than the melting point, although not good one to be melted under nonstationary large heat flux. (S.Y.)

  16. Pressurizer /Auxiliary Spray Piping Stress Analysis For Determination Of Lead Shielding Maximum Allow Able Load

    International Nuclear Information System (INIS)

    Setjo, Renaningsih

    2000-01-01

    Piping stress analysis for PZR/Auxiliary Spray Lines Nuclear Power Plant AV Unit I(PWR Type) has been carried out. The purpose of this analysis is to establish a maximum allowable load that is permitted at the time of need by placing lead shielding on the piping system on class 1 pipe, Pressurizer/Auxiliary Spray Lines (PZR/Aux.) Reactor Coolant Loop 1 and 4 for NPP AV Unit one in the mode 5 and 6 during outage. This analysis is intended to reduce the maximum amount of radiation dose for the operator during ISI ( In service Inspection) period.The result shown that the maximum allowable loads for 4 inches lines for PZR/Auxiliary Spray Lines is 123 lbs/feet

  17. High heat load properties of nanostructured, recrystallized W–1.1TiC

    Energy Technology Data Exchange (ETDEWEB)

    Tokunaga, K., E-mail: tokunaga@riam.kyushu-u.ac.jp [Research Institute for Applied Mechanics, Kyushu University, Kasuga, Fukuoka 816-8580 (Japan); Kurishita, H.; Arakawa, H.; Matsuo, S. [International Research Center for Nuclear Materials Science, IMR, Tohoku University, Oarai, Ibaraki 311-1313 (Japan); Hotta, T. [Interdisciplinary Graduate School of Engineering Sciences, Kyushu University, Kasuga, Fukuoka 816-8580 (Japan); Araki, K.; Miyamoto, Y.; Fujiwara, T.; Nakamura, K. [Research Institute for Applied Mechanics, Kyushu University, Kasuga, Fukuoka 816-8580 (Japan); Takida, T.; Kato, M.; Ikegaya, A. [A.L.M.T. Corp., Toyama 931-8543 (Japan)

    2013-11-15

    Steady state (1973 K, 180 s) and repeated (723 K–1524 K, 380 times) heat loading experiments of ITER grade W and toughened, fine-grained, recrystallized W–1.1TiC (TFGR W–1.1TiC) have been performed using an electron beam irradiation system. In ITER grade W, the irradiation around 1973 K causes recrystallization and grain growth up to the average diameters of 50–100 μm. Repeated irradiations cause significant surface roughening, cracking at grain boundaries and surface exfoliation. On the other hand, TFGR W–1.1TiC does not exhibit any surface roughening or cracking after repeated heat loading although grain boundaries on the surface of TFGR W–1.1TiC can be observed after irradiation at around 1973 K 180 s by steady state heat loading.

  18. Differences in HIV Type 1 RNA Plasma Load Profile of Closely Related Cocirculating Ethiopian Subtype C Strains: C and C '

    NARCIS (Netherlands)

    Ayele, Workenesh; Mekonnen, Yared; Messele, Tsehaynesh; Mengistu, Yohannes; Tsegaye, Aster; Bakker, Margreet; Berkhout, Ben; Dorigo-Zetsma, Wendelien; Wolday, Dawit; Goudsmit, Jaap; Coutinho, Roel; de Baar, Michel; Paxton, William A.; Pollakis, Georgios

    2010-01-01

    Two HIV-1 subtype C subclusters have been identified in Ethiopia (C and C') with little knowledge regarding their biological or clinical differences. We longitudinally monitored HIV-1 viral loads and CD4(+) T cell counts for 130 subtype C-infected individuals from Ethiopia over 5 years. The genetic

  19. Hybrid FRC under repeated loading

    International Nuclear Information System (INIS)

    Komlos, K.; Babal, B.; Nuernbergerova, T.

    1993-01-01

    Fibre reinforced concretes (FRC) containing several volume fractions in different ratios of two types of fibres - polypropylene and steel, were tested under repeated loading. Mechanical properties of specimens - cubes 150/150/150 mm (for compressive strength), prisms 100/100/400 (for flexural strength), short cylinders 150/60 mm (for impact strength) have been experimentally investigated before and after cyclic loading at the age of 28 days curing time. Mix proportions were designed after DIN 1045 with max. aggregate size 8 mm and grading curve B 8. Portland Cement PC 400 in the amount of 450 kg. m -3 was applied and W/C ratio 0.55. Workability of mixes was measured by Vebe method and regulated by plasticizing admixture Ligoplast Na. Maximum hybrid fibre volume fraction (polypropylene + steel) was 1.0%. Dynamic forces generated in Schenck testing machine with frequency 16 Hz had sinusoidal wave form varying between 0.7 and 0.1 of static mechanical characteristics. The number of cycles in all tests was 10 5 . The residual MOR at static four point bending test and working diagram force-deflection was carried out as well. The impact properties after repeated loading in compression were tested by means of falling weight test. Relationships between composition of fibre composites with different combination of polypropylene (0.2, 0.3, 0.5% by volume) and steel (0.5, 0.7, and 0.8% by volume) fibre content were obtained and technological properties of mixes as well. (author)

  20. High power RF performance test of an improved SiC load

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, W.H.; Kim, S.H.; Park, Y.J. [Pohang Accelerator Lab., Pohang Inst. of Sceince and Technology, Pohang (KR)] [and others

    1998-11-01

    Two prototypes of SiC loads sustaining a maximum peak power of 50 MW were fabricated by Nihon Koshuha Co. in Japan. The PAL conducted the high power RF performance tests of SiC loads to verify the operation characteristics for the application to the PLS Linac. The in-situ facility for the K 12 module was used for the test, which consists of a modulator and klystron system, waveguide network, vacuum and cooling system, and RF analyzing equipment. As the test results, no breakdown appeared up to 50 MW peak power of 1 {mu}s pulse width at a repetition rate of 50 Hz. However, as the peak power increased above 20 MW at 4 {mu}s with 10 Hz, the breakdown phenomena has been observed. Analysing the test results with the current operation power level of PLS Linac, it is confirmed that the SiC loads well satisfy the criteria of the PLS Linac operation. (author)

  1. 46 CFR 174.055 - Calculation of wind heeling moment (Hm).

    Science.gov (United States)

    2010-10-01

    ... for an exposed surface on the unit in foot-pounds (kilogram-meters); (2) k=0.00338 lb./(ft.2-knots2... (25.8 meters per second) for damage conditions. (4) A=projected area in square feet (squrae meters) of an exposed surface on the unit; (5) Ch=height coefficient for “A” from Table 174.055(a); (6) Cs=shape...

  2. Force Limited Vibration Testing: Computation C2 for Real Load and Probabilistic Source

    Science.gov (United States)

    Wijker, J. J.; de Boer, A.; Ellenbroek, M. H. M.

    2014-06-01

    To prevent over-testing of the test-item during random vibration testing Scharton proposed and discussed the force limited random vibration testing (FLVT) in a number of publications, in which the factor C2 is besides the random vibration specification, the total mass and the turnover frequency of the load(test item), a very important parameter. A number of computational methods to estimate C2 are described in the literature, i.e. the simple and the complex two degrees of freedom system, STDFS and CTDFS, respectively. Both the STDFS and the CTDFS describe in a very reduced (simplified) manner the load and the source (adjacent structure to test item transferring the excitation forces, i.e. spacecraft supporting an instrument).The motivation of this work is to establish a method for the computation of a realistic value of C2 to perform a representative random vibration test based on force limitation, when the adjacent structure (source) description is more or less unknown. Marchand formulated a conservative estimation of C2 based on maximum modal effective mass and damping of the test item (load) , when no description of the supporting structure (source) is available [13].Marchand discussed the formal description of getting C 2 , using the maximum PSD of the acceleration and maximum PSD of the force, both at the interface between load and source, in combination with the apparent mass and total mass of the the load. This method is very convenient to compute the factor C 2 . However, finite element models are needed to compute the spectra of the PSD of both the acceleration and force at the interface between load and source.Stevens presented the coupled systems modal approach (CSMA), where simplified asparagus patch models (parallel-oscillator representation) of load and source are connected, consisting of modal effective masses and the spring stiffnesses associated with the natural frequencies. When the random acceleration vibration specification is given the CMSA

  3. Photometric Selection of a Massive Galaxy Catalog with z ≥ 0.55

    Science.gov (United States)

    Núñez, Carolina; Spergel, David N.; Ho, Shirley

    2017-02-01

    We present the development of a photometrically selected massive galaxy catalog, targeting Luminous Red Galaxies (LRGs) and massive blue galaxies at redshifts of z≥slant 0.55. Massive galaxy candidates are selected using infrared/optical color-color cuts, with optical data from the Sloan Digital Sky Survey (SDSS) and infrared data from “unWISE” forced photometry derived from the Wide-field Infrared Survey Explorer (WISE). The selection method is based on previously developed techniques to select LRGs with z> 0.5, and is optimized using receiver operating characteristic curves. The catalog contains 16,191,145 objects, selected over the full SDSS DR10 footprint. The redshift distribution of the resulting catalog is estimated using spectroscopic redshifts from the DEEP2 Galaxy Redshift Survey and photometric redshifts from COSMOS. Restframe U - B colors from DEEP2 are used to estimate LRG selection efficiency. Using DEEP2, the resulting catalog has an average redshift of z = 0.65, with a standard deviation of σ =2.0, and an average restframe of U-B=1.0, with a standard deviation of σ =0.27. Using COSMOS, the resulting catalog has an average redshift of z = 0.60, with a standard deviation of σ =1.8. We estimate 34 % of the catalog to be blue galaxies with z≥slant 0.55. An estimated 9.6 % of selected objects are blue sources with redshift z0.55. Stellar contamination is estimated to be 1.8%.

  4. Grafting C8-C16 alkyl groups altered the self-assembly and curcumin –loading properties of sodium caseinate in water

    Directory of Open Access Journals (Sweden)

    Yaqiong Zhang

    2018-02-01

    Full Text Available The data presented here are related to the research article entitled “Synthesis and characterization of alkylated caseinate, and its structure-curcumin loading property relationship in water” (Zhang et al., 2018 [1]. This data article reports the detailed spectra information for 1H NMR, 13C NMR and UPLC-Q-TOF MS of the N-succinimidyl fatty acid esters with various alkyl chain lengths (Cn-NHSs, n = 8, 12, 14 and 16. 1H NMR, 13C NMR and UPLC-Q-TOF MS spectra for C16-NHS are shown as an example. Then the stacked 1H NMR spectra of the obtained alkylated caseinates (Cn-caseinates, n = 8, 12, 14 and 16 are provided. The surface hydrophobicity index (S0 of Cn-caseinates with different substitution degrees (SD of alkyl groups is shown. Additionally, Visual appearances for the formed aqueous dispersions of curcumin-loaded native caseinate (NaCas and Cn-caseinates self-assemblies are shown. X-ray diffraction patterns of curcumin, C16-caseinate, its physical mixture and curcumin-loaded C16-caseinate self-assemblies are examined. The re-dispersibility and short-term storage stability of the curcumin-loaded NaCas and C16-caseinate self-assemblies are also studied. Keywords: Caseinate, Alkylated caseinate, Self-assembly, Curcumin-loading property

  5. C-Reactor I and E loading instability limits

    Energy Technology Data Exchange (ETDEWEB)

    Hess, K.W.

    1957-01-24

    The pilot charging of I & E fuel elements has been implemented at C-Reactor under Production Test IP-19-A. It was necessary to provide adequate tube protection against flow interruption by establishing proper trip setting on the Panellit pressure gauges. the administration of these Panellit trip settings is done by trip-before- boiling tube outlet temperature limits, which are similar in principle to the current instability limits. Trip-before-boiling limits for C-Reactor I & E fuel elements loadings are presented in this document.

  6. High Heat Load Properties of Ultra Fine Grain Tungsten

    International Nuclear Information System (INIS)

    Zhou, Z.; Du, J.; Ge, C.; Linke, J.; Pintsuk, G.; Song, S.X.

    2007-01-01

    Full text of publication follows: Tungsten is increasingly considered as a promising candidate armour materials facing the plasma in tokamaks for medium to high heat flux components (EAST, ASDEX, ITER). Fabrication tungsten with ultra fine grain size is considered as an effective way to ameliorate some disadvantages of tungsten, such as its brittleness at room temperature. But the research data on the performance of ultra fine grain tungsten is still very limit. In this work, high heat load properties of pure ultra-fine grain tungsten have been studied. The ultra fine grain tungsten samples with average grain size of 0.2 μm, 1 μm and 3 μm were fabricated by resistance sintering under ultra high pressure. The annealing experiments for the investigation of the material resistance against grain growth have been done by annealing samples in a vacuum furnace at different temperature holding for 2 hours respectively. It is found that recrystallization and grain growth occur at heating temperature of 1250 deg. c. The finer the initial grain sizes of tungsten, the smaller its grain growth grain. The effects of transient high thermal loads (off normal events like disruptions) on tungsten surface morphology have been performed in electron beam test facility JUDITH. The thermal loads tests have been carried out with 4 ms pulses at different power density of 0.22, 0.33, 0.44, 0.55 and 0.88 GW/m 2 respectively. Horizontal cracks formed for all tungsten samples at 0.44 GW/m 2 . Particle erosions occurred for tungsten with 3 μm size at 0.33 GW/m 2 and for tungsten with 0.2 and 1 μm size at 0.55 GW/m 2 . The weight loss of tungsten with 0.2, 1 and 3 μm size are 2,0.1,0.6 mg respectively at 0.88 GW/m 2 . The effects of a large number of very short transient repetitive thermal loads (ELM-like) on tungsten surface morphology also have been performed by using a fundamental wave of a YAG laser. It is found that tungsten with 0.2 μm size has the best performance. (authors)

  7. High Heat Load Properties of Ultra Fine Grain Tungsten

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Z.; Du, J.; Ge, C. [Lab. of Special Ceramic and P/M, University of Science and Technology, 100083 Beijing (China); Linke, J.; Pintsuk, G. [FZJ-Forschungszentrum Juelich GmbH, Association Euratom-FZJ, Institut fur Plasmaphysik, Postfach 1913, D-52425 Juelich (Germany); Song, S.X. [Research Center on Fusion Materials (RCFM), University of Science and Technology Beijing (USTB), 100083 Beijing (China)

    2007-07-01

    Full text of publication follows: Tungsten is increasingly considered as a promising candidate armour materials facing the plasma in tokamaks for medium to high heat flux components (EAST, ASDEX, ITER). Fabrication tungsten with ultra fine grain size is considered as an effective way to ameliorate some disadvantages of tungsten, such as its brittleness at room temperature. But the research data on the performance of ultra fine grain tungsten is still very limit. In this work, high heat load properties of pure ultra-fine grain tungsten have been studied. The ultra fine grain tungsten samples with average grain size of 0.2 {mu}m, 1 {mu}m and 3 {mu}m were fabricated by resistance sintering under ultra high pressure. The annealing experiments for the investigation of the material resistance against grain growth have been done by annealing samples in a vacuum furnace at different temperature holding for 2 hours respectively. It is found that recrystallization and grain growth occur at heating temperature of 1250 deg. c. The finer the initial grain sizes of tungsten, the smaller its grain growth grain. The effects of transient high thermal loads (off normal events like disruptions) on tungsten surface morphology have been performed in electron beam test facility JUDITH. The thermal loads tests have been carried out with 4 ms pulses at different power density of 0.22, 0.33, 0.44, 0.55 and 0.88 GW/m{sup 2} respectively. Horizontal cracks formed for all tungsten samples at 0.44 GW/m{sup 2}. Particle erosions occurred for tungsten with 3 {mu}m size at 0.33 GW/m{sup 2} and for tungsten with 0.2 and 1 {mu}m size at 0.55 GW/m{sup 2}. The weight loss of tungsten with 0.2, 1 and 3 {mu}m size are 2,0.1,0.6 mg respectively at 0.88 GW/m{sup 2}. The effects of a large number of very short transient repetitive thermal loads (ELM-like) on tungsten surface morphology also have been performed by using a fundamental wave of a YAG laser. It is found that tungsten with 0.2 {mu}m size has

  8. Grafting C8-C16 alkyl groups altered the self-assembly and curcumin -loading properties of sodium caseinate in water.

    Science.gov (United States)

    Zhang, Yaqiong; Yang, Puyu; Yao, Fangyi; Liu, Jie; Yu, Liangli Lucy

    2018-02-01

    The data presented here are related to the research article entitled "Synthesis and characterization of alkylated caseinate, and its structure-curcumin loading property relationship in water" (Zhang et al., 2018) [1]. This data article reports the detailed spectra information for 1 H NMR, 13 C NMR and UPLC-Q-TOF MS of the N-succinimidyl fatty acid esters with various alkyl chain lengths (Cn-NHSs, n = 8, 12, 14 and 16). 1 H NMR, 13 C NMR and UPLC-Q-TOF MS spectra for C16-NHS are shown as an example. Then the stacked 1 H NMR spectra of the obtained alkylated caseinates (Cn-caseinates, n = 8, 12, 14 and 16) are provided. The surface hydrophobicity index (S 0 ) of Cn-caseinates with different substitution degrees (SD) of alkyl groups is shown. Additionally, Visual appearances for the formed aqueous dispersions of curcumin-loaded native caseinate (NaCas) and Cn-caseinates self-assemblies are shown. X-ray diffraction patterns of curcumin, C16-caseinate, its physical mixture and curcumin-loaded C16-caseinate self-assemblies are examined. The re-dispersibility and short-term storage stability of the curcumin-loaded NaCas and C16-caseinate self-assemblies are also studied.

  9. DISSECTING THE REGION OF 3EG J1837-0423 AND HESS J1841-055 WITH INTEGRAL

    International Nuclear Information System (INIS)

    Sguera, V.; Masetti, N.; Bassani, L.; Romero, G. E.; Bazzano, A.; Bird, A. J.

    2009-01-01

    3EG J1837-0423 and HESS J1841-055 are two unidentified and peculiar high-energy sources located in the same region of the sky, separated by ∼1.4 deg. Specifically, 3EG J1837-0423 is a transient MeV object detected by EGRET only once during flaring activity that lasted a few days while HESS J1841-055 is a highly extended TeV source. We attempted to match the high-energy emission from the unidentified sources 3EG J1837-0423 and HESS J1841-055 with X-rays (4-20 keV) and soft γ-rays (20-100 keV) candidate counterparts detected through deep International Gamma-Ray Astrophysics Laboratory observations of the sky region. As a result we propose the Supergiant Fast X-ray Transient (SFXT) AX J1841.0-0536 as a possible candidate counterpart of 3EG J1837-0423, based on spatial proximity and transient behavior. Alternatively, AX J1841.0-0536 could be responsible for at least a fraction of the entire TeV emission from the extended source HESS J1841-055, based on a striking spatial correlation. In either case, the proposed association is also supported from an energetic standpoint by a theoretical scenario where AX J1841.0-0536 is a low magnetized pulsar which, due to accretion of massive clumps from the supergiant companion donor star, undergoes sporadic changes to transient Atoll-states where a magnetic tower can produce transient jets and as a consequence high-energy emission. In either case (by association with 3EG J1837-0423 or alternatively with HESS J1841-055), AX J1841.0-0536 might be the prototype of a new class of Galactic transient MeV/TeV emitters.

  10. Characterization of fiber optic cables under large tensile loads

    International Nuclear Information System (INIS)

    Ogle, J.W.; Looney, L.D.; Peterson, R.T.

    1984-01-01

    Fiber optic cables designed for the Nevada Test Site (NTS) have to withstand an unusually harsh environment. Cables have been manufactured under a 6 year old DOE specification that has been slightly modified as the cable requirements are better understood. In order to better understand the cable properties a unique capability has been established at the NTS. Instrumentation has been developed to characterize the transmission properties of 1 km of fiber optic cable placed under a controlled tensile load up to 1500 lbs. The properties measured are cable tension, cable elongation, induced attenuation, attenuation vs. location, fiber strain, bandwidth, and ambient temperature. Preforming these measurements on cables from the two qualified NTS fiber optic cable manufacturers, Siecor and Andrew Corp., led to a new set of specifications

  11. Feasibility study of a vertical slit for the LBS line of the Linac4

    CERN Document Server

    Ouzia, Alexandre; Maglioni, Cesare; Leitao, Ivo

    The feasibility study of a vertical Slit was performed. This Slit is needed for the diagnostic Line for Beam energy Spread of the Linac 4 (LBS line). The Linac 4 will replace the Linac 2 and enable the Large Hadron Collider (LHC) to reach an energy of 14 TeV (highest energy ever reached). When the beam impact on it, the Slit heats up and deforms. The deformation of the slit is the key problem. The present feasibility study aims at assessing whether or not it is feasible to keep this deformation below 50_m, according to the specifications [14]. The determination of all the issues related with the Slit was driven. The priority was given to the thermo-mechanical issues. The methodology chosen to approach the problem led to three steps: -\tFirst, the determination of possible designs for the Slit. One design was identified. -\tSecond, the determination of the best materials. Two figures of merit and a model were specifically conceived for it. Graphite R4550 was identified as the best material. -\tThird, the Monte-Ca...

  12. Test Report: Assembly and Structural Loading of Army Research Lab’s High Strength Low Alloy - Vanadium (HSLA - V) Bridge

    Science.gov (United States)

    2010-04-28

    34 to 1" drive adapter MHE ============ 15,000 lbs forklift 6,000 lbs. forklift 5,000 pallet truck Two 30,000 lbs. 6’x16’ caster wheeled carts...Suggested modifications to reduce assembly time* ================================================== Use powered torque multipliers to torque bolts

  13. Disorder influence on the magnetic properties of La0.55Sr0.45MnO3/SrTiO3 superlattices

    International Nuclear Information System (INIS)

    Haberkorn, N.; Sirena, M.; Guimpel, J.; Steren, L.B.

    2004-01-01

    The structural and physical properties of La 0.55 Sr 0.45 MnO 3 /SrTiO 3 superlattices grown by magnetron sputtering are studied. Two deposition temperatures and different mismatched substrates and buffer layers were used. The structure was determined by refinement through X-ray diffraction pattern fitting. The results indicate 1 unit cell (u.c.) interdiffusion at the interfaces and a 1 u.c. layer thickness fluctuation, i.e. roughness. In-plane hysteresis loops show the expected ferromagnetic behavior, while the perpendicular-to-plane hysteresis loops show anomalies which could evidence magnetic domain size inhomogeneities and stress

  14. Characteristic study of high-T{sub c} superconducting maglev under side-loading

    Energy Technology Data Exchange (ETDEWEB)

    Wang Wei [Applied Superconductivity Laboratory, M/S 152, Southwest Jiaotong University, Chengdu, Sichuan 610031 (China)], E-mail: frank.weiwang@gmail.com; Wang Jiasu [Applied Superconductivity Laboratory, M/S 152, Southwest Jiaotong University, Chengdu, Sichuan 610031 (China)], E-mail: asclab@asclab.cn; Liu Wei; Zheng Jun; Lin Qunxu; Pan Siting; Deng Zigang; Ma Guangtong; Wang Suyu [Applied Superconductivity Laboratory, M/S 152, Southwest Jiaotong University, Chengdu, Sichuan 610031 (China)

    2009-02-15

    In practical application of High-T{sub c} Superconducting (HTS) maglev, slant is an observable defect. It was caused by constantly one side on and off the vehicle by passengers. So far, this phenomenon has not been reported yet. In order to understand its influence on the stability of the HTS maglev, we experimentally studied the dynamic characteristic and slant effect of HTS maglev under center-load and side-load. It was found that load destabilizes the vehicle, and the side-load can obviously slant the vehicle body. In the end, the pre-load method was proposed to enhance the dynamic stability and suppress the slant, which proved to be considerably effective. These results are critical in practical running of HTS maglev.

  15. The Bristol "Badminton" Airplane

    Science.gov (United States)

    1926-01-01

    The Bristol Badminton, Type 99 airplane has a radial aircooled engine (a Bristol Jupiter 9 cylinder 450 HP.) and three fuel tanks. It is a single seat biplane weighing 1,840 lbs. empty and 2,460 lbs. loaded.

  16. Development of a hysteresis model for R/C columns subjected to bi-axial lateral loading

    International Nuclear Information System (INIS)

    Dutta, Sekhar Chandra; Chowdhury, Rajib; Roy, Raghupati; Reddy, G. Rami

    2003-01-01

    Recent investigations on dynamic response of reinforced concrete (R/C) structures have confirmed that the R/C structural members undergo much more inelastic deformation in each of the two mutually perpendicular directions under bi-directional seismic loading, than that observed only under unidirectional ground motion. To predict the seismic response of R/C structure with fair accuracy demands, a faithful model that can incorporate the effect of biaxial bending interaction in column. This model should not have high computational demand but should adequately reflect the stiffness degrading and strength deterioration characteristics of R/C structural members. Present study is an effort to develop such a bi-directional hysteresis model accounting the effect of interaction between lateral loadings in two orthogonal directions. The development of the present model is based on the yield surface approach and it can incorporate both strength and stiffness degradation characteristics, which is unavoidable in R/C structures during cyclic loading. The performance of the proposed model/ is demonstrated through the prediction of available experimental results of a reinforced concrete column, subjected to biaxial loading. (author)

  17. Dicty_cDB: Contig-U05216-1 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available 064701 ) WNEL14b1 Wheat EST endosperm library Triticum aes... 40 0.032 2 ( AC200123 ) Zea mays chromosome 4 ... CF-24-HW fat cDNA... 36 0.055 2 ( EG551033 ) MM04K05_RP Sugar Beet germination cDNA library Be... 36 0.055 2 ( AG332587 ) Mus muscul...7 2 ( AZ506962 ) 1M0348D20F Mouse 10kb plasmid UUGC1M library Mus ... 40 0.057 2 ( BB898919 ) Macaca fascicul...V968176 ) GC06167 Gracilaria changii cDNA library Gracilari... 46 0.014 2 ( AG430324 ) Mus musculus molossin..._IpSto_12_p10 Stomach cDNA library Ictalurus p... 32 0.76 2 ( DX535456 ) GH_MBb0065G22f GH_MBb Gossypium hirsutum genomic

  18. Rapid healing of cutaneous leishmaniasis by high-frequency electrocauterization and hydrogel wound care with or without DAC N-055: a randomized controlled phase IIa trial in Kabul.

    Directory of Open Access Journals (Sweden)

    Ahmad Fawad Jebran

    2014-02-01

    Full Text Available Anthroponotic cutaneous leishmaniasis (CL due to Leishmania (L. tropica infection is a chronic, frequently disfiguring skin disease with limited therapeutic options. In endemic countries healing of ulcerative lesions is often delayed by bacterial and/or fungal infections. Here, we studied a novel therapeutic concept to prevent superinfections, accelerate wound closure, and improve the cosmetic outcome of ACL.From 2004 to 2008 we performed a two-armed, randomized, double-blinded, phase IIa trial in Kabul, Afghanistan, with patients suffering from L. tropica CL. The skin lesions were treated with bipolar high-frequency electrocauterization (EC followed by daily moist-wound-treatment (MWT with polyacrylate hydrogel with (group I or without (group II pharmaceutical sodium chlorite (DAC N-055. Patients below age 5, with facial lesions, pregnancy, or serious comorbidities were excluded. The primary, photodocumented outcome was the time needed for complete lesion epithelialization. Biopsies for parasitological and (immunohistopathological analyses were taken prior to EC (1(st, after wound closure (2(nd and after 6 months (3(rd. The mean duration for complete wound closure was short and indifferent in group I (59 patients, 43.1 d and II (54 patients, 42 d; p = 0.83. In patients with Leishmania-positive 2(nd biopsies DAC N-055 caused a more rapid wound epithelialization (37.2 d vs. 58.3 d; p = 0.08. Superinfections occurred in both groups at the same rate (8.8%. Except for one patient, reulcerations (10.2% in group I, 18.5% in group II; p = 0.158 were confined to cases with persistent high parasite loads after healing. In vitro, DAC N-055 showed a leishmanicidal effect on pro- and amastigotes.Compared to previous results with intralesional antimony injections, the EC plus MWT protocol led to more rapid wound closure. The tentatively lower rate of relapses and the acceleration of wound closure in a subgroup of patients with parasite persistence warrant

  19. Real field mission profile oriented design of a SiC-based PV-inverter application

    DEFF Research Database (Denmark)

    Sintamarean, Nicolae Christian; Blaabjerg, Frede; Wang, Huai

    2013-01-01

    This paper introduces a real field mission profile oriented design tool for the new generation of grid connected PV-inverters applications based on SiC-devices. The proposed design tool consists of a grid connected PV-inverter model, an ElectroThermal model, a converter safe operating area (SOA...... Zth_H in order to perform in a safe mode for the whole operating range. Furthermore, the proposed design tool considers the mission profile (the measured solar irradiance and ambient temperature) from the real field where the converter will operate. Thus, a realistic loading of the converter devices......) model, a mission profile model and an the evaluation block. The PV-system model involves a three level bipolar switch neutral point clamped (3L-BS NPC) inverter connected to the three phase grid through a LCL-filter. Moreover, the SOA model calculates the required converter heatsink thermal impedance...

  20. Effect of reverse cyclic loading on the fracture resistance curve in C(T) specimen

    International Nuclear Information System (INIS)

    Sung Seok, C.; Jin Kim, Y.; Il Weon, J.

    1999-01-01

    Fracture resistance (J-R) curves, which are used for elastic-plastic fracture mechanics analyses, are known to be dependent on the cyclic loading history. The objective of this paper is to investigate the effect of reverse cyclic loading on the J-R curves in C(T) specimens. The effect of two parameters was observed on the J-R curves during the reverse cyclic loading. One was the minimum-to-maximum load ratio (R) and the other was the incremental plastic displacement (δ cycle /δ i ), which is related to the amount of crack growth that occurs in a cycle. Fracture resistance tests on C(T) specimens with varying the load ratio and the incremental plastic displacement were performed, and the test results showed that the J-R curves were decreased with decreasing the load ratio and decreasing the incremental plastic displacement. Direct current potential drop (DCPD) method was used for the detection of crack initiation and crack growth in typical laboratory J-R tests. The values of crack initiation J-integral (J I ) and crack initiation displacement (δ i ) were also obtained by using the DCPD method. (orig.)

  1. Dicty_cDB: VFE826 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available rmelon lambda zap library Citrullus lanatus cDNA clone WMLS336 5' similar to acetyl...of Vitis vinifera var. Chardonnay Vitis vinifera cDNA clone VVC055H06 5, mRNA sequence. 60 3e-08 2 AI563047 |AI563047.1 EST00171 wate

  2. Effect of load eccentricity on the buckling of thin-walled laminated C-columns

    Science.gov (United States)

    Wysmulski, Pawel; Teter, Andrzej; Debski, Hubert

    2018-01-01

    The study investigates the behaviour of short, thin-walled laminated C-columns under eccentric compression. The tested columns are simple-supported. The effect of load inaccuracy on the critical and post-critical (local buckling) states is examined. A numerical analysis by the finite element method and experimental tests on a test stand are performed. The samples were produced from a carbon-epoxy prepreg by the autoclave technique. The experimental tests rest on the assumption that compressive loads are 1.5 higher than the theoretical critical force. Numerical modelling is performed using the commercial software package ABAQUS®. The critical load is determined by solving an eigen problem using the Subspace algorithm. The experimental critical loads are determined based on post-buckling paths. The numerical and experimental results show high agreement, thus demonstrating a significant effect of load inaccuracy on the critical load corresponding to the column's local buckling.

  3. Experiment data report for Semiscale Mod-1 Test S-05-5 (alternate ECC injection test)

    International Nuclear Information System (INIS)

    Collins, B.L.; Patton, M.L. Jr.; Sackett, K.E.

    1977-04-01

    Recorded test data are presented for Test S-05-5 of the Semiscale Mod-1 alternate ECC injection test series. These tests are among several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Test S-05-5 was conducted from initial conditions of 2263 psia and 537 0 F to investigate the response of the Semiscale Mod-1 system to a depressurization and reflood transient following a simulated double-ended offset shear of the cold leg broken loop piping. During the test, cooling water was injected into the cold leg of the intact and broken loops to simulate emergency core coolant injection in a PWR. The upper plenum was vented through a reflood bypass line interconnecting the hot and cold legs of the broken loop

  4. D0 Silicon Upgrade: West End Assembly Hall Platform Design Calculations

    International Nuclear Information System (INIS)

    Rucinski, Russ

    1996-01-01

    This engineering note documents design calculations done for the bayonet feed can platform installed at the far west end of the assembly hall. The platform is mounted off of a cast concrete wall directly south of where the shielding block wall is stacked. A summary of the loading, reaction forces and stresses is shown on the page 3. As can be seen, the calculated stresses are very small, maximum value = 2540 psi. The material used is structural steel tubing, ASTM A500 Gr. B, with a minimum yield strength of 46 ksi and minimum ultimate tensile strength of 58 ksi. The reaction forces for the upper two members will be carried together by a 1/2-inch mounting plate. The mounting plate is attached to the wall by four 1/2-inch Hilti wedge anchors. The allowables for each wedge anchor are 2400 lbs. tensile, 1960 lbs. shear. The major reaction load for the top members is a combined 3627 lbs. tensile load which can easily be handled by the four bolt pattern. Some small moment reactions not listed on the summary page add negligible (400 lbs.) force couples to the axial loading. The bottom members are also attached to a mounting plate that is bolted to the wall. See page 15 for Hilti wedge anchor data.

  5. INDOOR LOCALIZATION USING WI-FI BASED FINGERPRINTING AND TRILATERATION TECHIQUES FOR LBS APPLICATIONS

    Directory of Open Access Journals (Sweden)

    S. Chan

    2012-06-01

    Full Text Available The past few years have seen wide spread adoption of outdoor positioning services, mainly GPS, being incorporated into everyday devices such as smartphones and tablets. While outdoor positioning has been well received by the public, its indoor counterpart has been mostly limited to private use due to its higher costs and complexity for setting up the proper environment. The objective of this research is to provide an affordable mean for indoor localization using wireless local area network (WLAN Wi-Fi technology. We combined two different Wi-Fi approaches to locate a user. The first method involves the use of matching the pre-recorded received signal strength (RSS from nearby access points (AP, to the data transmitted from the user on the fly. This is commonly known as "fingerprint matching". The second approach is a distance-based trilateration approach using three known AP coordinates detected on the user's device to derive the position. The combination of the two steps enhances the accuracy of the user position in an indoor environment allowing location-based services (LBS such as mobile augmented reality (MAR to be deployed more effectively in the indoor environment. The mapping of the RSS map can also prove useful to IT planning personnel for covering locations with no Wi-Fi coverage (ie. dead spots. The experiments presented in this research helps provide a foundation for the integration of indoor with outdoor positioning to create a seamless transition experience for users.

  6. Lbs Augmented Reality Assistive System for Utilities Infrastructure Management Through Galileo and Egnos

    Science.gov (United States)

    Stylianidis, E.; Valaria, E.; Smagas, K.; Pagani, A.; Henriques, J.; Garca, A.; Jimeno, E.; Carrillo, I.; Patias, P.; Georgiadis, C.; Kounoudes, A.; Michail, K.

    2016-06-01

    There is a continuous and increasing demand for solutions, both software and hardware-based, that are able to productively handle underground utilities geospatial data. Innovative approaches that are based on the use of the European GNSS, Galileo and EGNOS, sensor technologies and LBS, are able to monitor, document and manage utility infrastructures' data with an intuitive 3D augmented visualisation and navigation/positioning technology. A software and hardware-based system called LARA, currently under develop- ment through a H2020 co-funded project, aims at meeting that demand. The concept of LARA is to integrate the different innovative components of existing technologies in order to design and develop an integrated navigation/positioning and information system which coordinates GNSS, AR, 3D GIS and geodatabases on a mobile platform for monitoring, documenting and managing utility infrastruc- tures on-site. The LARA system will guide utility field workers to locate the working area by helping them see beneath the ground, rendering the complexity of the 3D models of the underground grid such as water, gas and electricity. The capacity and benefits of LARA are scheduled to be tested in two case studies located in Greece and the United Kingdom with various underground utilities. The paper aspires to present the first results from this initiative. The project leading to this application has received funding from the European GNSS Agency under the European Union's Horizon 2020 research and innovation programme under grant agreement No 641460.

  7. LBS AUGMENTED REALITY ASSISTIVE SYSTEM FOR UTILITIES INFRASTRUCTURE MANAGEMENT THROUGH GALILEO AND EGNOS

    Directory of Open Access Journals (Sweden)

    E. Stylianidis

    2016-06-01

    Full Text Available There is a continuous and increasing demand for solutions, both software and hardware-based, that are able to productively handle underground utilities geospatial data. Innovative approaches that are based on the use of the European GNSS, Galileo and EGNOS, sensor technologies and LBS, are able to monitor, document and manage utility infrastructures’ data with an intuitive 3D augmented visualisation and navigation/positioning technology. A software and hardware-based system called LARA, currently under develop- ment through a H2020 co-funded project, aims at meeting that demand. The concept of LARA is to integrate the different innovative components of existing technologies in order to design and develop an integrated navigation/positioning and information system which coordinates GNSS, AR, 3D GIS and geodatabases on a mobile platform for monitoring, documenting and managing utility infrastruc- tures on-site. The LARA system will guide utility field workers to locate the working area by helping them see beneath the ground, rendering the complexity of the 3D models of the underground grid such as water, gas and electricity. The capacity and benefits of LARA are scheduled to be tested in two case studies located in Greece and the United Kingdom with various underground utilities. The paper aspires to present the first results from this initiative. The project leading to this application has received funding from the European GNSS Agency under the European Union’s Horizon 2020 research and innovation programme under grant agreement No 641460.

  8. Indoor Localization Using Wi-Fi Based Fingerprinting and Trilateration Techiques for Lbs Applications

    Science.gov (United States)

    Chan, S.; Sohn, G.

    2012-06-01

    The past few years have seen wide spread adoption of outdoor positioning services, mainly GPS, being incorporated into everyday devices such as smartphones and tablets. While outdoor positioning has been well received by the public, its indoor counterpart has been mostly limited to private use due to its higher costs and complexity for setting up the proper environment. The objective of this research is to provide an affordable mean for indoor localization using wireless local area network (WLAN) Wi-Fi technology. We combined two different Wi-Fi approaches to locate a user. The first method involves the use of matching the pre-recorded received signal strength (RSS) from nearby access points (AP), to the data transmitted from the user on the fly. This is commonly known as "fingerprint matching". The second approach is a distance-based trilateration approach using three known AP coordinates detected on the user's device to derive the position. The combination of the two steps enhances the accuracy of the user position in an indoor environment allowing location-based services (LBS) such as mobile augmented reality (MAR) to be deployed more effectively in the indoor environment. The mapping of the RSS map can also prove useful to IT planning personnel for covering locations with no Wi-Fi coverage (ie. dead spots). The experiments presented in this research helps provide a foundation for the integration of indoor with outdoor positioning to create a seamless transition experience for users.

  9. Properties of single-walled carbon nanotube-based aerogels as a function of nanotube loading

    International Nuclear Information System (INIS)

    Worsley, Marcus A.; Pauzauskie, Peter J.; Kucheyev, Sergei O.; Zaug, Joseph M.; Hamza, Alex V.; Satcher, Joe H.; Baumann, Theodore F.

    2009-01-01

    Here, we present the synthesis and characterization of low-density single-walled carbon nanotube-based aerogels (SWNT-CA). Aerogels with varying nanotube loading (0-55 wt.%) and density (20-350 mg cm -3 ) were fabricated and characterized by four-probe method, electron microscopy, Raman spectroscopy and nitrogen porosimetry. Several properties of the SWNT-CAs were highly dependent upon nanotube loading. At nanotube loadings of 55 wt.%, shrinkage of the aerogel monoliths during carbonization and drying was almost completely eliminated. Electrical conductivities are improved by an order of magnitude for the SWNT-CA (55 wt.% nanotubes) compared to those of foams without nanotubes. Surface areas as high as 184 m 2 g -1 were achieved for SWNT-CAs with greater than 20 wt.% nanotube loading.

  10. A national discharge load of perfluoroalkyl acids derived from industrial wastewater treatment plants in Korea

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hee-Young; Seok, Hyun-Woo [Department of Civil and Environmental Engineering, Pusan National University, Busan 46241 (Korea, Republic of); Kwon, Hye-Ok; Choi, Sung-Deuk [School of Urban and Environmental Engineering, Ulsan National Institute of Science and Technology, Ulsan 44919 (Korea, Republic of); Seok, Kwang-Seol [Chemical Research Division, National Institute of Environmental Research, Incheon 22689 (Korea, Republic of); Oh, Jeong Eun [Department of Civil and Environmental Engineering, Pusan National University, Busan 46241 (Korea, Republic of)

    2016-09-01

    Levels of 11 perfluoroalkyl acids (PFAAs), including perfluorooctanoic acid (PFOA) and perfluorooctane sulfonic acid (PFOS), were measured in wastewater (influent and effluent) and sludge samples collected from 25 industrial wastewater treatment plants (I-WWTPs) in five industrial sectors (chemicals, electronics, metals, paper, and textiles) in South Korea. The highest ∑{sub 11}PFAAs concentrations were detected in the influent and effluent from the paper (median: 411 ng/L) and textile (median: 106 ng/L) industries, and PFOA and PFOS were the predominant PFAAs (49–66%) in wastewater. Exceptionally high levels of PFAAs were detected in the sludge associated with the electronics (median: 91.0 ng/g) and chemical (median: 81.5 ng/g) industries with PFOS being the predominant PFAA. The discharge loads of 11 PFAAs from I-WWTP were calculated that total discharge loads for the five industries were 0.146 ton/yr. The textile industry had the highest discharge load with 0.055 ton/yr (PFOA: 0.039 ton/yr, PFOS: 0.010 ton/yr). Municipal wastewater contributed more to the overall discharge of PFAAs (0.489 ton/yr) due to the very small industrial wastewater discharge compared to municipal wastewater discharge, but the contribution of PFAAs from I-WWTPs cannot be ignored. - Highlights: • 11 PFAAs in wastewater and sludge from 5 industrial sectors were investigated. • PFOA and PFOS were the dominant in wastewater while PFOS was predominant in sludge. • The total discharge loads from 5 industrial sectors 0.146 ton/yr. • The textile industry showed the highest discharge load with 0.055 ton/yr.

  11. Kinetic modeling of divertor heat load fluxes in the Alcator C-Mod and DIII-D tokamaks

    Energy Technology Data Exchange (ETDEWEB)

    Pankin, A. Y. [Tech-X Corporation, Boulder, Colorado 80303 (United States); Rafiq, T.; Kritz, A. H. [Department of Physics, Lehigh University, Bethlehem, Pennsylvania 18015 (United States); Park, G. Y. [National Fusion Research Institute, Daejeon, 305-333 (Korea, Republic of); Chang, C. S.; Ku, S. [Princeton Plasma Physics Laboratory, Princeton, New Jersey 08540 (United States); Brunner, D.; Hughes, J. W.; LaBombard, B.; Terry, J. L. [MIT Plasma Science and Fusion Center, Cambridge, Massachusetts 02139 (United States); Groebner, R. J. [General Atomics, San Diego, California 92121 (United States)

    2015-09-15

    The guiding-center kinetic neoclassical transport code, XGC0 [Chang et al., Phys. Plasmas 11, 2649 (2004)], is used to compute the heat fluxes and the heat-load width in the outer divertor plates of Alcator C-Mod and DIII-D tokamaks. The dependence of the width of heat-load fluxes on neoclassical effects, neutral collisions, and anomalous transport is investigated using the XGC0 code. The XGC0 code includes realistic X-point geometry, a neutral source model, the effects of collisions, and a diffusion model for anomalous transport. It is observed that the width of the XGC0 neoclassical heat-load is approximately inversely proportional to the total plasma current I{sub p.} The scaling of the width of the divertor heat-load with plasma current is examined for an Alcator C-Mod discharge and four DIII-D discharges. The scaling of the divertor heat-load width with plasma current is found to be weaker in the Alcator C-Mod discharge compared to scaling found in the DIII-D discharges. The effect of neutral collisions on the 1/I{sub p} scaling of heat-load width is shown not to be significant. Although inclusion of poloidally uniform anomalous transport results in a deviation from the 1/I{sub p} scaling, the inclusion of the anomalous transport that is driven by ballooning-type instabilities results in recovering the neoclassical 1/I{sub p} scaling. The Bohm or gyro-Bohm scalings of anomalous transport do not strongly affect the dependence of the heat-load width on plasma current. The inclusion of anomalous transport, in general, results in widening the width of neoclassical divertor heat-load and enhances the neoclassical heat-load fluxes on the divertor plates. Understanding heat transport in the tokamak scrape-off layer plasmas is important for strengthening the basis for predicting divertor conditions in ITER.

  12. Hepatitis C virus genotypes: A plausible association with viral loads

    Directory of Open Access Journals (Sweden)

    Salma Ghulam Nabi

    2013-01-01

    Full Text Available Background and Aim: The basic aim of this study was to find out the association of genotypes with host age, gender and viral load. Material and Methods: The present study was conducted at Social Security Hospital, Pakistan. This study included 320 patients with chronic hepatitis C virus (HCV infection who were referred to the hospital between November 2011 and July 2012. HCV viral detection and genotyping was performed and the association was seen between genotypes and host age, gender and viral load. Results : The analysis revealed the presence of genotypes 1 and 3 with further subtypes 1a, 1b, 3a, 3b and mixed genotypes 1b + 3a, 1b + 3b and 3a + 3b. Viral load quantification was carried out in all 151 HCV ribonucleic acid (RNA positive patients. The genotype 3a was observed in 124 (82.12% patients, 3b was found in 21 (13.91%, 1a was seen in 2 (1.32%, 1b in 1 (0.66%, mixed infection with 1b + 3a in 1 (0.66%, 1b + 3b in 1 (0.66% and 3a + 3b was also found in 1 (0.66% patient. Viral load quantification was carried out in all 151 HCV RNA positive patients and was compared between the various genotypes. The mean viral load in patients infected with genotype 1a was 2.75 × 10 6 , 1b 3.9 × 10 6 , 3a 2.65 × 10 6 , 3b 2.51 × 10 6 , 1b + 3a 3.4 × 106, 1b + 3b 2.7 × 106 and 3a + 3b 3.5 × 10 6 . An association between different types of genotypes and viral load was observed. Conclusion : Further studies should be carried out to determine the association of viral load with different genotypes so that sufficient data is available and can be used to determine the type and duration of therapy needed and predict disease outcome.

  13. Different patterns of vein loading of exogenous [14C]sucrose in leaves of pisum sativum and coleus blumei

    International Nuclear Information System (INIS)

    Turgeon, R.; Wimmers, L.E.

    1988-01-01

    Vein loading of exogenous [ 14 C]sucrose was studied using short uptake and wash periods to distinguish between direct loading into veins and loading via mesophyll tissue. Mature leaf tissue of Pisum sativum L. cv Little Marvel, or Coleus blumei Benth. cv Candidum, was abraded and leaf discs were floated on [ 14 C]sucrose solution for 1 or 2 minutes. Discs were then washed for 1 to 30 min either at room temperature or in the cold and were frozen, lyophilized, and autoradiographed. In P. sativum, veins were clearly labeled after 1 minute uptake and 1 minute wash periods. Autoradiographic images did not change appreciably with longer times of uptake or wash. Vein loading was inhibited by p-chloromercuribenzenesulfonic acid. These results indicate that uptake of exogenous sucrose occurs directly into the veins in this species. When C. blumei leaf discs were floated on [ 14 C]sucrose for 2 minutes and washed in the cold, the mesophyll was labeled but little, if any, minor vein loading occurred. When discs were labeled for 2 minutes and washed at room temperature, label was transferred from the mesophyll to the veins within minutes. These results indicate that there may be different patterns of phloem loading of photosynthetically derived sucrose in these two species

  14. In vivo survival of [14C]sucrose-loaded porcine carrier erythrocytes

    International Nuclear Information System (INIS)

    DeLoach, J.R.

    1983-01-01

    Porcine carrier erythrocyte survival was measured in adult pigs. [14C]Sucrose-loaded erythrocytes had a biphasic survival curve, with as much as 50% of the cells removed from circulation in the first 24 hours. The remaining cells had a 35-day half-life. Encapsulation values were measured for porcine erythrocytes and entrapment of [14C]sucrose was greater than 45%. Addition of inosine and glucose to the dialyzed cells and to the final wash buffer before reinjection of autologous cells did not improve their survival

  15. Sequence elements correlating with circulating viral load in genotype 1b hepatitis C virus infection

    International Nuclear Information System (INIS)

    Watanabe, Hideki; Nagayama, Kazuyoshi; Enomoto, Nobuyuki; Itakura, Jun; Tanabe, Yoko; Hamano, Kosei; Izumi, Namiki; Sato, Chifumi; Watanabe, Mamoru

    2003-01-01

    The correlation between hepatitis C virus (HCV) genomic sequences and circulating HCV RNA levels was assessed to investigate the genetic elements affecting viral load. The interferon sensitivity-determining region (ISDR) sequence and the serum viral load were strongly correlated in 226 patients examined. Analysis of the entire HCV genome from six patients (three with a high and the others with a low viral load) with similar ISDR sequences identified several candidate residues associated with viral load. The amino acid (aa) sequences of these candidate residues and flanking regions in 67 additional patients revealed that only the residue at aa 962 varied significantly between the HCV patients with low and high serum loads (P 0.042). At this position, alanine was observed more frequently in the patients with a high viral load. In conclusion, our results strongly suggest that serum HCV RNA loads are inversely correlated with amino acid substitutions in the ISDR, and aa 962 was identified as a possible second determinant of serum HCV RNA load

  16. Immunogenicity of diphtheria toxoid and poly(I:C) loaded cationic liposomes after hollow microneedle-mediated intradermal injection in mice.

    Science.gov (United States)

    Du, Guangsheng; Leone, Mara; Romeijn, Stefan; Kersten, Gideon; Jiskoot, Wim; Bouwstra, Joke A

    2018-06-02

    In this study, we aimed to investigate the immunogenicity of cationic liposomes loaded with diphtheria toxoid (DT) and poly(I:C) after hollow microneedle-mediated intradermal vaccination in mice. The following liposomal formulations were studied: DT loaded liposomes, a mixture of free DT and poly(I:C)-loaded liposomes, a mixture of DT-loaded liposomes and free poly(I:C), and liposomal formulations with DT and poly(I:C) either individually or co-encapsulated in the liposomes. Reference groups were DT solution adjuvanted with or without poly(I:C) (DT/poly(I:C)). The liposomal formulations were characterized in terms of particle size, zeta potential, loading and release of DT and poly(I:C). After intradermal injection of BALB/c mice with the formulations through a hollow microneedle, the immunogenicity was assessed by DT-specific ELISAs. All formulations induced similar total IgG and IgG1 titers. However, all the liposomal groups containing both DT and poly(I:C) showed enhanced IgG2a titers compared to DT/poly(I:C) solution, indicating that the immune response was skewed towards a Th1 direction. This enhancement was similar for all liposomal groups that contain both DT and poly(I:C) in the formulations. Our results reveal that a mixture of DT encapsulated liposomes and poly(I:C) encapsulated liposomes have a similar effect on the antibody responses as DT and poly(I:C) co-encapsulated liposomes. These findings may have implications for future design of liposomal vaccine delivery systems. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  17. Inhibition of loading of 14C assimilate by p-chloromercuribenzenesulfonic acid

    International Nuclear Information System (INIS)

    Bourquin, S.; Bonnemain, J.L.; Delrot, S.

    1990-01-01

    The apoplast of mature leaves excised from broadbean (Vicia faba L.) plants was infiltrated with 2 millimolar p-chloromercuribenzenesulfonic acid (PCMBS) via the transpiration stream, and the ability of the tissues to take up sugars was tested. An infiltration time of 75 minutes was sufficient of obtain a maximal (75%) inhibition of exogenous [ 14 C]sucrose (1 millimolar) uptake. This infiltration affected neither CO 2 assimilation nor the transmembrane potential difference of leaf cells but strongly inhibited phloem loading of endogenous [ 14 C] assimilates. The study of the symplastic relations between the different cell types of the mature leaf showed that the density of the plasmodesmata is generally very low in comparison with other species investigated so far, particularly when considering the mesophyll/bundle sheath and the bundle sheath/phloem cells connections, as well as the connections of the transfer cell-sieve tube complex with the surrounding cells. These three successive barriers therefore strongly limit the possibilities of symplastic transit of the assimilates to the conducting cells. The comparison of the densities of plasmodesmata in an importing and an exporting leaf suggests that the maturation of the leaf is characterized by a marked symplastic isolation of the phloem, and, within the phloem itself, by the isolation of the conducting complex. As a consequence, these physiological and cytological data demonstrate the apoplastic nature of loading in the mature leaf of Vicia faba, this species undoubtedly presenting a typical model for apoplastic loading

  18. Behaviour of C-shaped angle shear connectors under monotonic and fully reversed cyclic loading: An experimental study

    International Nuclear Information System (INIS)

    Shariati, Mahdi; Ramli Sulong, N.H.; Suhatril, Meldi; Shariati, Ali; Arabnejad Khanouki, M.M.; Sinaei, Hamid

    2012-01-01

    Highlights: ► C-shaped angle connectors show 8.8–33.1% strength degradation under cyclic loading. ► Connector fracture type of failure was experienced in C-shaped angle shear connectors. ► In push-out samples, more cracking was observed in those slabs with longer angles. ► C-shaped angle connectors show good behaviour in terms of the ultimate shear capacity. ► C-shaped angle connectors did not fulfil the requirements for ductility criteria. -- Abstract: This paper presents an evaluation of the structural behaviour of C-shaped angle shear connectors in composite beams, suitable for transferring shear force in composite structures. The results of the experimental programme, including eight push-out tests, are presented and discussed. The results include resistance, strength degradation, ductility, and failure modes of C-shaped angle shear connectors, under monotonic and fully reversed cyclic loading. The results show that connector fracture type of failure was experienced in C-shaped angle connectors and after the failure, more cracking was observed in those slabs with longer angles. On top of that, by comparing the shear resistance of C-shaped angle shear connectors under monotonic and cyclic loading, these connectors showed 8.8–33.1% strength degradation, under fully reversed cyclic loading. Furthermore, it was concluded that the mentioned shear connector shows a proper behaviour, in terms of the ultimate shear capacity, but it does not satisfy the ductility criteria, imposed by the Eurocode 4, to perform a plastic distribution of the shear force between different connectors along the beam length.

  19. Disorder influence on the magnetic properties of La{sub 0.55}Sr{sub 0.45}MnO{sub 3}/SrTiO{sub 3} superlattices

    Energy Technology Data Exchange (ETDEWEB)

    Haberkorn, N. E-mail: nhaberk@cab.cnea.gov.ar; Sirena, M.; Guimpel, J.; Steren, L.B

    2004-05-01

    The structural and physical properties of La{sub 0.55}Sr{sub 0.45}MnO{sub 3}/SrTiO{sub 3} superlattices grown by magnetron sputtering are studied. Two deposition temperatures and different mismatched substrates and buffer layers were used. The structure was determined by refinement through X-ray diffraction pattern fitting. The results indicate 1 unit cell (u.c.) interdiffusion at the interfaces and a 1 u.c. layer thickness fluctuation, i.e. roughness. In-plane hysteresis loops show the expected ferromagnetic behavior, while the perpendicular-to-plane hysteresis loops show anomalies which could evidence magnetic domain size inhomogeneities and stress.

  20. Dicty_cDB: Contig-U01295-1 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available 215673-... 38 0.14 7 ( FG288127 ) 1108793259903 New World Screwworm Egg 9261 ESTs C... 40 0.14 2 ( DQ855586...p. nucleatum ATCC 255... 50 0.15 1 ( FG286381 ) 1108770714831 New World Screwworm Egg 9261 ESTs C... 40 0.15...( FM992688 ) Candida dubliniensis CD36 chromosome 1, complete ... 44 0.55 6 ( FG296422 ) 1108793252569 New World

  1. Contractors Road Heavy Equipment Area SWMU 055 Corrective Measures Implementation Progress Report

    Science.gov (United States)

    Dorman, Lane

    2015-01-01

    This Corrective Measures Implementation (CMI) Progress Report, Revision 1, for Contractor's Road Heavy Equipment (CRHE) Area Solid Waste Management Unit (SWMU) Number 055 was prepared by Geosyntec Consultants (Geosyntec) for the National Aeronautics and Space Administration (NASA) under contract number NNK09CA02B, Delivery Order NNK09CA62D and Project Number PCN ENV-2324. This CMI Progress Report documents: (i) activities conducted as part of supplemental assessment activities completed from June 2009 through November 2014; (ii) Engineering Evaluation (EE) Advanced Data Packages (ADPs); and (iii) recommendations for future activities related to corrective measures at the Site.

  2. The effect of antioxidant supplementation on hepatitis C viral load, transaminases and oxidative status: a randomized trial among chronic hepatitis C virus-infected patients

    DEFF Research Database (Denmark)

    Groenbaek, K.; Friis, H.; Hansen, Max

    2006-01-01

    Objective To assess the effect of antioxidant supplementation on hepatitis C viral load, transaminases and oxidative status. Methods We performed a randomized, placebo-controlled, double-blind trial to assess the effect of antioxidant supplementation on serum alanine aminotransferase, plasma...... hepatitis C viral load as well as oxidative and antioxidant markers in patients with hepatitis C virus infection. The participants received a daily dose of ascorbic acid (500 mg), D-alpha-tocopherol (9451 U) and selenium (200 mu g) or placebo tablets for 6 months. Results Twenty-three patients were included...... aminotransferase and logo-transformed plasma hepatitis C virus-RNA between the groups or changes from the baseline at any time. No consistent differences between groups or changes from the baseline with respect to erythrocyte activities of antioxidative enzymes (glutathione reductase, superoxide dismutase...

  3. Semi-continuous anaerobic digestion of solid poultry slaughterhouse waste: effect of hydraulic retention time and loading.

    Science.gov (United States)

    Salminen, Esa A; Rintala, Jukka A

    2002-07-01

    We studied the effect of hydraulic retention time (HRT) and loading on anaerobic digestion of poultry slaughterhouse wastes, using semi-continuously fed, laboratory-scale digesters at 31 degrees C. The effect on process performance was highly significant: Anaerobic digestion appeared feasible with a loading of up to 0.8 kg volatile solids (VS)/m3 d and an HRT of 50-100 days. The specific methane yield was high, from 0.52 to 0.55 m3/kg VS(added). On the other hand, at a higher loading, in the range from 1.0 to 2.1 kg VS/m3 d, and a shorter HRT, in the range from 25 to 13 days, the process appeared inhibited and/or overloaded, as indicated by the accumulation of volatile fatty acids and long-chain fatty acids and the decline in the methane yield. However, the inhibition was reversible. The nitrogen in the feed, ca. 7.8% of total solids (TS), was organic nitrogen with little ammonia present, whereas in the digested material ammonia accounted for 52-67% (up to 3.8 g/l) of total nitrogen. The TS and VS removals amounted to 76% and 64%, respectively. Our results show that on a continuous basis under the studied conditions and with a loading of up to 0.8 kg VS/m3 d metric ton (wet weight) of the studied waste mixture could yield up to 140 m3 of methane.

  4. Fixation effects on the release of copper, chromium and arsenic from CCA-C treated marine piles

    Science.gov (United States)

    Stan Lebow

    1999-01-01

    This study sought to determine the effect of fixation time and temperature on the release of copper, chromium and arsenic from treated marine piles immersed in seawater under "worst case" conditions. Sections of piles were CCA-C treated to a target retention of 2.5 lbs/ft3) (40 kg/m3) and then allowed to Condition at 36°F (2°C) for either 3, 7 or 20 days. As...

  5. Estimating Production Cost While Linking Combat Systems and Ship Design

    Science.gov (United States)

    2012-12-01

    Displacement  (lbs)  full load  Length  (ft)  overall  Beam (ft) overall   Max  Speed  (kts)  Crew  Helicopter  Montenegro   Kotor class  4188800  317  42  27...normalized it to US FY12$. Table 2. SWBSE acquired from NAVSEA data (After NAVSEA 05C). 100—Hull Structure 200—Propulsion Plant 300—Electrical Plant

  6. End-of-Treatment-Response in Patients Treated for Hepatitis C Virus with Standard Interferon and Ribavirin Based on Viral Load

    International Nuclear Information System (INIS)

    Rathore, M. A.; Hussain, A. B.; Ghani, E.

    2015-01-01

    Objective: To determine the End-of-Treatment-Response (ETR) to standard interferon and ribavirin based regimen in patients of chronic hepatitis C and to compare the ETR response in low and high viral load groups. Study Design: Descriptive study. Place and Duration of Study: Virology Department, Armed Forces Institute of Pathology (AFIP), Rawalpindi, from March 2012 to May 2013. Methodology: Patients with chronic hepatitis C virus infection were included in the study. Pre-treatment viral load was determined by RoboGene Quantification kit. Based on viral load, the 400 patients were divided into two equal groups of low viral load (< 800,000 IU/ml) and high viral load (> 800,000 IU/ml). The patients were treated with standard interferon alpha (3 million units subcutaneously thrice weekly) and ribavirin (10.6 mg/kg body weight) for 6 months. ETR was measured using Sacace Biotechnologies Qualitative kit. Chi-square test was used to compare the ETR in the two viral load groups. P-value < 0.05 was considered as significant. Results: Out of 400 patients, 206 (51.5%) were males and 194 (48.5%) were females. Two hundred seventy (67.5%) patients achieved ETR and 130 (35.5%) failed to do so. In low viral load group, 145 (72.5%) patients achieved and 55 (27.5%) patients did not achieve ETR. In high viral load group, 123 (61.5%) patients achieved and 77 (38.5%) did not achieve ETR. The difference in ETR between low and high viral load groups was statistically significant (p=0.019). Conclusion: End-of-treatment-response in patients treated for hepatitis C virus with standard interferon and ribavirin was greater in patients with low viral load as compared to patients with high viral load. (author)

  7. Influence of load and reinforcement content on selected tribological properties of Al/SiC/Gr hybrid composites

    Directory of Open Access Journals (Sweden)

    Sandra Veličković

    2018-04-01

    Full Text Available Hybrid materials with the metal matrix are important engineering materials due to their outstanding mechanical and tribological properties. Here are presented selected tribological properties of the hybrid composites with the matrix made of aluminum alloy and reinforced by the silicon carbide and graphite particles. The tribological characteristics of such materials are superior to characteristics of the matrix – the aluminum alloy, as well as to characteristics of the classical metal-matrix composites with a single reinforcing material. Those characteristics depend on the volume fractions of the reinforcing components, sizes of the reinforcing particles, as well as on the fabrication process of the hybrid composites. The considered tribological characteristics are the friction coefficient and the wear rate as functions of the load levels and the volume fractions of the graphite and the SiC particles. The wear rate increases with increase of the load and the Gr particles content and with reduction of the SiC particles content. The friction coefficient increases with the load, as well as with the SiC particles content increase.

  8. Grafting C8-C16 alkyl groups altered the self-assembly and curcumin –loading properties of sodium caseinate in water

    OpenAIRE

    Yaqiong Zhang; Puyu Yang; Fangyi Yao; Jie Liu; Liangli (Lucy) Yu

    2018-01-01

    The data presented here are related to the research article entitled “Synthesis and characterization of alkylated caseinate, and its structure-curcumin loading property relationship in water” (Zhang et al., 2018) [1]. This data article reports the detailed spectra information for 1H NMR, 13C NMR and UPLC-Q-TOF MS of the N-succinimidyl fatty acid esters with various alkyl chain lengths (Cn-NHSs, n = 8, 12, 14 and 16). 1H NMR, 13C NMR and UPLC-Q-TOF MS spectra for C16-NHS are shown as an exampl...

  9. Hepatitis C viral load, genotype 3 and interleukin-28B CC genotype predict mortality in HIV and hepatitis C-coinfected individuals

    DEFF Research Database (Denmark)

    Clausen, Louise Nygaard; Astvad, Karen; Ladelund, Steen

    2012-01-01

    OBJECTIVE: We hypothesized that hepatitis C virus (HCV) load and genotype may influence all-cause mortality in HIV-HCV-coinfected individuals. DESIGN AND METHODS: Observational prospective cohort study. Mortality rates were compared in a time-updated multivariate Poisson regression analysis....... RESULTS: We included 264 consecutive HIV-HCV-coinfected individuals. During 1143 person years at risk (PYR) 118 individuals died [overall mortality rate 10 (95% confidence interval; 8, 12)/100 PYR]. In multivariate analysis, a 1 log increase in HCV viral load was associated with a 30% higher mortality......) CC genotype was associated with 54% higher mortality risk [aMRR: 1.54 (0.89, 3.82] compared to TT genotype. CONCLUSION: High-HCV viral load, HCV genotype 3 and IL28B genotype CC had a significant influence on the risk of all-cause mortality among individuals coinfected with HIV-1. This may have...

  10. Superconductivity with twofold symmetry in Bi2Te3/FeTe0.55Se0.45 heterostructures

    Science.gov (United States)

    Du, Zengyi

    2018-01-01

    Topological superconductors are an interesting and frontier topic in condensed matter physics. In the superconducting state, an order parameter will be established with the basic or subsidiary symmetry of the crystalline lattice. In doped Bi2Se3 or Bi2Te3 with a basic threefold symmetry, it was predicted, however, that bulk superconductivity with order parameters of twofold symmetry may exist because of the presence of odd parity. We report the proximity effect–induced superconductivity in the Bi2Te3 thin film on top of the iron-based superconductor FeTe0.55Se0.45. By using the quasiparticle interference technique, we demonstrate clear evidence of twofold symmetry of the superconducting gap. The gap minimum is along one of the main crystalline axes following the so-called Δ4y notation. This is also accompanied by the elongated vortex shape mapped out by the density of states within the superconducting gap. Our results provide an easily accessible platform for investigating possible topological superconductivity in Bi2Te3/FeTe0.55Se0.45 heterostructures. PMID:29888330

  11. Dendritic cells induce specific cytotoxic T lymphocytes against prostate cancer TRAMP-C2 cells loaded with freeze- thaw antigen and PEP-3 peptide.

    Science.gov (United States)

    Liu, Xiao-Qi; Jiang, Rong; Li, Si-Qi; Wang, Jing; Yi, Fa-Ping

    2015-01-01

    Prostate cancer is the most common cancer in men. In this study, we investigated immune responses of cytotoxic T lymphocytes (CTLs) against TRAMP-C2 prostate cancer cells after activation by dendritic cells (DCs) loaded with TRAMP-C2 freeze-thaw antigen and/or PEP-3 peptide in vitro. Bone marrow-derived DC from the bone marrow of the C57BL/6 were induced to mature by using the cytokine of rhGM-CSF and rhIL-4, and loaded with either the freeze-thaw antigen or PEP-3 peptide or both of them. Maturation of DCs was detected by flow cytometry. The killing efficiency of the CTLs on TRAMP-C2 cells were detected by flow cytometry, CCK8, colony formation, transwell migration, and wound-healing assay. The levels of the IFN-γ, TNF-β and IL-12 were measured by enzyme-linked immunosorbent assay (ELISA). Compared with the unloaded DCs, the loaded DCs had significantly increased expression of several phenotypes related to DC maturation. CTLs activated by DCs loaded with freeze-thaw antigen and PEP-3 peptide had more evident cytotoxicity against TRAMP-C2 cells in vitro. The secretion levels of IFN-γ, TNF-β and IL-12, secreted by DCs loaded with antigen and PEP-3 and interaction with T cells, were higher than in the other groups. Our results suggest that the CTLs activated by DCs loaded with TRAMP-C2 freeze-thaw antigen and PEP-3 peptide exert a remarkable killing efficiency against TRAMP-C2 cells in vitro.

  12. Associations between Dietary Acid-Base Load and Cardiometabolic Risk Factors in Adults: The Tehran Lipid and Glucose Study

    Directory of Open Access Journals (Sweden)

    Zahra Bahadoran

    2015-06-01

    Full Text Available BackgroundIn this study we investigated the associations of dietary acid-base load, identified by potential renal acid load (PRAL and protein to potassium (Pro:K ratio, with cardiometabolic risk factors in Tehranian adults.MethodsA cross-sectional study was conducted within the framework of the fourth phase of the Tehran Lipid and Glucose Study (2009 to 2011 on 5,620 men and women aged 19 to 70 years. Dietary data were collected by a trained dietitian using a validated, 147-food item, semi-quantitative food frequency questionnaire, and dietary PRAL and Pro:K ratio were calculated. Multiple linear regression models with adjustment for potential confounding variables were used to evaluate the associations of dietary acid-base load with anthropometric measures, blood pressure, serum triglycerides, high density lipoprotein cholesterol (HDL-C, serum creatinine, and fasting blood glucose.ResultsThe mean±SD age of the participants was 39.8±12.8 years and 54% of participants were women. Mean±SD PRAL was -22.0±29.1; mean PRAL was -15.6 in men and -26.8 in women. Dietary PRAL was associated with weight (β=0.098, P<0.001, waist circumference (β=0.062, P<0.01, serum triglycerides (β=0.143, P<0.01, HDL-C (β=-0.11, P<0.01, diastolic blood pressure (β=0.062, P<0.01, and serum creatinine (β=0.142, P<0.001. Pro:K ratio was associated with weight (β=0.055, P<0.001, waist circumference (β=0.04, P<0.01, serum HDL-C (β=-0.06, P<0.01, serum triglycerides (β=0.03, P<0.05, diastolic blood pressure (β=0.026, P<0.05, and serum creatinine (β=0.07, P<0.01.ConclusionA more acidic dietary acid-base load may be a risk factor for the development of metabolic disorders.

  13. Effect of thermal annealing on electron spin relaxation of beryllium-doped In0.8Ga0.2As0.45P0.55 bulk

    Directory of Open Access Journals (Sweden)

    Hao Wu

    2016-08-01

    Full Text Available The effect of thermal annealing on the electron spin relaxation of beryllium-doped In0.8Ga0.2As0.45P0.55 bulk was investigated by time-resolved spin-dependent pump and probe reflection measurement with a high time resolution of 200 fs. Three similar InGaAsP samples were examined one of which was annealed at 800 °C for 1 s, one was annealed at 700 °C for 1 s and the other was not annealed after crystal growth by molecular beam epitaxy. Although the carrier lifetimes of the 700 °C-annealed sample and the unannealed sample were similar, that of the 800 °C-annealed sample was extended to 11.6 (10.4 ns at 10 (300 K, which was more than two (four times those of the other samples. However, interestingly the spin relaxation time of the 800 °C-annealed sample was found to be similar to those of the other two samples. Particularly at room temperature, the spin relaxation times are 143 ps, 147 ps, and 111 ps for the 800 °C-annealed sample, 700 °C-annealed sample, and the unannealed sample, respectively.

  14. Visceral fat area is associated with HbA1c but not dialysate-related glucose load in nondiabetic PD patients

    Science.gov (United States)

    Ho, Li-Chun; Yen, Chung-Jen; Chao, Chia-Ter; Chiang, Chih-Kang; Huang, Jenq-Wen; Hung, Kuan-Yu

    2015-08-01

    Factors associated with increased visceral fat area (VFA) have been well documented in the general population but rarely explored in nondiabetic individuals on peritoneal dialysis (PD). As glycosylated hemoglobin (HbA1c) is positively correlated with VFA in diabetic patients, we hypothesized that the same correlation would exist in nondiabetic PD patients. We enrolled 105 nondiabetic patients who had undergone chronic PD for more than 3 months. Each subject underwent an abdominal computed tomography (CT) scan, and the umbilicus cut was analyzed for VFA. VFA values, corrected for body mass index and subjected to natural logarithm transformations, were examined to determine whether they were correlated with HbA1c and other parameters. PD dialysates prescribed at the time of enrollment were recorded to calculate glucose load. We found that when 105 nondiabetic PD patients were classified according to tertiles of HbA1c, higher HbA1c was associated with larger VFA. Multiple linear regression analysis revealed that HbA1c was an independent determinant of VFA, while glucose load and other PD-specific factors were not. In summary, HbA1c, but not PD-related glucose load, was positively correlated with VFA in nondiabetic PD patients, suggesting clinical utility of HbA1c in the PD population.

  15. Two gap superconductivity in Ba0.55K0.45Fe2As2 single crystals studied by the directional point-contact Andreev reflection spectroscopy

    International Nuclear Information System (INIS)

    Szabo, P.; Pribulova, Z.; Pristas, G.; Bud'ko, S.L.; Canfield, P.C.; Samuely, P.

    2009-01-01

    First directional point-contact Andreev reflection spectroscopy on the Ba 0.55 K 0.45 Fe 2 As 2 single crystals is presented. The spectra show significant differences when measured in the ab plane in comparison with those measured in the c direction. In the latter case no traces of superconducting energy gap could be found, just a reduced point-contact conductance persisting up to about 100 K and indicating reduced density of states. On the other hand within the ab plane two nodeless superconducting energy gaps Δ S ∼2-5 meV and Δ L ∼9-11 meV are detected.

  16. Theoretical and experimental study of disordered Ba0.45Sr0.55 TiO3 photoluminescence at room temperature

    International Nuclear Information System (INIS)

    Souza, I.A.; Gurgel, M.F.C.; Santos, L.P.S.; Goes, M.S.; Cava, S.; Cilense, M.; Rosa, I.L.V.; Paiva-Santos, C.O.; Longo, E.

    2006-01-01

    Disordered and crystalline Ba 0.45 Sr 0.55 TiO 3 (BST) powder processed at low temperature was synthesized by the polymeric precursor method. The single-phase perovskite structure of the ceramics was identified by the Raman and X-ray diffraction techniques. Photoluminescence at room temperature was observed only in a disordered BST sample. Increasing the calcination time intensified the photoluminescence (PL), which reached its maximum value in the sample heat treated at 300 deg. C for 30 h. This emission may be correlated with the structural disorder. Periodic ab initio quantum-mechanical calculations using the CRYSTAL98 program can yield important information regarding the electronic and structural properties of crystalline and disordered solids. The experimental and theoretical results indicate the presence of intermediary energy levels in the band gap. This is ascribed to the break in symmetry, which is responsible for visible photoluminescence in the material's disordered state at room temperature

  17. Lightweight Towed Howitzer Demonstrator. Phase 1 and Partial Phase 2. Volume F. Systems Engineering Analysis (QA, Test Plans).

    Science.gov (United States)

    1987-04-01

    FAIILURE MOVDE SPECMEN LOAD REQ ’D PE (ADHES ION, SPC NO. WI=l ADHESIVE TOD PEEI 5 IN. STRENG COHESION, OR RANZ’IT1= W (IN) THICKESS P (LBS) P/W BASE...area, squat * incries nomina. thickness 9 moeasuced widthl) b - width. measured to ;@&cost 0.00, inch (se T nabnle ht 1117s .31culated Eros nominal...no&na 101ms-sec1ona area. squat LneCes(nooln cno 7:*s-n 4 c nm i tickes., I a (measured Vkdthl f. Tonse Strain Uti .L ,c-o &n./Ln. - See Flbque 4 The

  18. Ferroelectric properties and diffuse phase transition in (Pb,La)Zrsub(0.55)Tisub(0.45)O3 ceramics

    International Nuclear Information System (INIS)

    Wolters, M.

    1976-01-01

    A preparation technique for (Pb,La)Zrsub(0.55)Tisub(0.45)O 3 ceramics is described by which inhomogeneities are eliminated. Grain size effects are studied and ferroelectric-paraelectric phase-transitions are investigated by means of X-ray diffraction analysis and dielectric weak-field (permittivity) and high-field (dc bias and hysteresis) measurements

  19. New load cycling strategy for enhanced durability of high temperature proton exchange membrane fuel cell

    DEFF Research Database (Denmark)

    Thomas, Sobi; Jeppesen, Christian; Steenberg, Thomas

    2017-01-01

    The objective of this paper is to develop a new operational strategy to increase the lifetime of a high temperature proton exchange membrane (HT-PEMFCs) fuel cell system by using load cycling patterns to reduce the phosphoric acid loss from the fuel cell. Four single cells were operated under.......8 Acm-2 for the higher end, were selected for the load cycling operation. The relaxation time, which is the period of time spent at low current density operation, is varied to understand how the performance over prolonged period behaves. The duration of the high current density operation is selected...... based on the relaxation time in order to have the same average current density of (0.55 Acm-2 ) for all the cells. Cell 5, with a relaxation time of 2 min performs best and shows lower degradation rate of 36 μVh-1 compared to other load cycling cells with smaller relaxation times. The cell operated...

  20. DIFFERENCES IN THE KNEE TORQUE BETWEEN HIGH- AND LOW-BAR BACK SQUAT TECHNIQUES. A PILOT STUDY

    Directory of Open Access Journals (Sweden)

    Janez Logar

    2015-01-01

    Full Text Available Purpose: The squat is one of the most frequently used exercises in sports training and competitions. There are several squat variations: i the front squat (FS, ii the high-bar back squat (HBS and iii the low-bar back squat (LBS. As the biomechanics of the LBS technique have been studied to a lesser extent, therefore the purpose of this pilot study was to analyze the differences in knee joint net muscle torque between the HBS and LBS. Methods: One healthy male subject (180.0 cm, 76.0 kg, 26 years performed 10 steady paced squats (5 HBS and 5 LBS with additional weight (40.4 kg to a 90° knee angle. Kinematic and kinetic data were gathered using a high-speed camcorder and a force plate, respectively. The maximal and average knee joint net muscle torques (Mmax and Mavg were then calculated via 2-dimensional inverse dynamics. Results: A significantly greater Mavg was observed using the HBS technique as compared to the LBS, both during the entire range of the squat (MavgHBS = 221.6 ± 5.1 Nm, MavgLBS= 203.3 ± 10.2 Nm; p = 0.026 as well as during the eccentric (MavgHBS = 226.0 ± 5.9 Nm, MavgLBS= 202.0 ± 14.0 Nm; p = 0.043 and concentric (MavgHBS = 216.2 ± 3.6 Nm, MavgLBS= 205.0 ± 7.9 Nm; p = 0.021 phase separately. Conclusions: It can be concluded that the lower Mavg during the LBS could be due to the load transfer to the hip joint, most likely because of the greater anterior tilt of the torso, which is a direct response to a lower and more posterior bar placement on the back to finally maintain an unchanged centre of mass. Confirmation of these findings in a larger sample would imply that the LBS could be a more appropriate squat technique when knee joint relief is desired.

  1. 17 CFR 270.6c-10 - Exemption for certain open-end management investment companies to impose deferred sales loads.

    Science.gov (United States)

    2010-04-01

    ... management investment companies to impose deferred sales loads. 270.6c-10 Section 270.6c-10 Commodity and... ACT OF 1940 § 270.6c-10 Exemption for certain open-end management investment companies to impose... purposes of this section: (1) Company means a registered open-end management investment company, other than...

  2. Modeling of creep-fatigue interaction of zirconium α under cyclic loading at 200 C

    International Nuclear Information System (INIS)

    Vogel, C.

    1996-04-01

    The present work deals with mechanical behaviour of zirconium alpha at 200 deg. C and crack initiation prediction methods, particularly when loading conditions lead to interaction of fatigue and creep phenomena. A classical approach used to study interaction between cyclic effects and constant loading effects does not give easy understanding of experimental results. Therefore, a new approach has been developed, which allow to determine a number of cycles for crack initiation for complex structures under large loading conditions. To study influence of fatigue and creep interaction on crack initiation, a model was chosen, using a scalar variable, giving representation of the material deterioration state. The model uses a non linear cumulating effect between the damage corresponding to cyclic loads and the damage correlated to time influence. The model belongs to uncoupled approaches between damage and behaviour, which is described here by a two inelastic deformations model. This mechanical behaviour model is chosen because it allows distinction between a plastic and a viscous part in inelastic flow. Cyclic damage is function of stress amplitude and mean stress. For the peculiar sensitivity of the material to creep, a special parameter bas been defined to be critical toward creep damage. It is the kinematic term associated to state variables describing this type of hardening in the viscous mechanism. (author)

  3. Studies of diluted antiferromagnets MnxMg1-xTiO3 with x=0.55 and 0.70 by muon spin relaxation method

    International Nuclear Information System (INIS)

    Fukaya, A.; Ito, A.; Torikai, E.; Nishiyama, K.; Nagamine, K.

    1997-01-01

    Longitudinal fields μSR measurements have been performed in order to probe the spin dynamics in the diluted antiferromagnets Mn x Mg 1-x TiO 3 with x=0.70 and 0.55. In the x=0.70 sample which forms the antiferromagnetic long-range order, the static and fluctuating fields coexist at the muon stopping site below T N . On the other hand, in the x=0.55 sample which shows the spin-glass behavior, the local fields fluctuate rather fast even below T SG . We infer that this drastic change occurs when Mn x Mg 1-x TiO 3 transforms from an antiferromagnetic system to a spin-glass system by dilution

  4. Macrophyte Community Response to Nitrogen Loading and ...

    Science.gov (United States)

    Empirical determination of nutrient loading thresholds that negatively impact seagrass communities have been elusive due to the multitude of factors involved. Using a mesocosm system that simulated Pacific Northwest estuaries, we evaluated macrophyte metrics across gradients of NO3 loading (0, 1.5, 3 and 6x ambient) and temperature (10 and 20 °C). Macroalgal growth, biomass, and C:N responded positively to increased NO3 load and floating algal mats developed at 20 ºC. Zostera japonica metrics, including C:N, responded more to temperature than to NO3 loading. Z. marina biomass exhibited a negative temperature effect and in some cases a negative NO3 effect, while growth rate increased with temperature. Shoot survival decreased at 20 ºC but was not influenced by NO3 loading. Wasting disease index exhibited a significant temperature by NO3 interaction consistent with increased disease susceptibility. Community shifts observed were consistent with the nutrient loading hypothesis at 20 ºC, but there was no evidence of other eutrophication symptoms due to the short residence time. The Nutrient Pollution Index tracked the NO3 gradient at 10 ºC but exhibited no response at 20 ºC. We suggest that systems characterized by cool temperatures, high NO3 loads, and short residence time may be resilient to many symptoms of eutrophication. Estuarine systems characterized by cool temperatures, high nutrient loads and rapid flushing may be resilient to some symptoms

  5. Dicty_cDB: CHB202 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available bacillus plantarum strain WCFS1 complete genome; segment 9/11. 46 0.55 1 U92221 |U92221.1 Legionella shake...spearei macrophage infectivity potentiator (mip) gene, complete cds. 46 0.55 1 AC11

  6. 2D micromechanical analysis of SiC/Al metal matrix composites under tensile, shear and combined tensile/shear loads

    DEFF Research Database (Denmark)

    Qing, Hai

    2013-01-01

    The influence of interface strength and loading conditions on the mechanical behavior of the metal-matrix composites is investigated in this paper. A program is developed to generate automatically 2D micromechanical Finite element (FE) models including interface, in which both the locations...... and dimensions of Silicon-Carbide (SiC) particles are randomly distributed. Finite element simulations of the deformation and damage evolution of SiC particle reinforced Aluminum (Al) alloy composite are carried out for different microstructures and interphase strengths under tensile, shear and combined tensile....../shear loads. 2D cohesive element is applied to describe the fracture and failure process of interphase, while the damage models based on maximum principal stress criterion and the stress triaxial indicator are developed within Abaqus/Standard Subroutine USDFLD to simulate the failure process of SiC particles...

  7. Engineering assessment of 105 K basin monorails

    International Nuclear Information System (INIS)

    Frier, W.A.

    1995-01-01

    The engineering assessment of the 105 K Basins monorails was performed to provide the engineering analysis to justify the existing basin north-south monorail capacity. The existing monorails have a capacity of 2400 lbs posted on the north-south monorails. The engineering assessment concluded that the monorail, hanger system, and trolleys all rate for a 2000 lb capacity. Based upon a 2,500 lb trolley load, the monorails, the hanger system, and the double trolley hoist system will rate for 2,500 lbs. The single trolley hoist system for handling the fuel canisters and the trolley systems used in the various transfer areas are limited by manufacturers to 2,000 lbs. Therefore, it is concluded from this engineering assessment that the 2,400 lb capacity posting for the north-south basin monorails is appropriate

  8. 21 CFR 524.1610 - Orbifloxacin, mometasone furoate monohydrate, and posaconazole suspension.

    Science.gov (United States)

    2010-04-01

    ... HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS OPHTHALMIC AND TOPICAL.... 000061 in § 510.600(c) of this chapter. (c) Conditions of use in dogs—(1) Amount. For dogs weighing less than 30 lbs. instill 4 drops once daily into the ear canal. For dogs weighing 30 lbs. or more, instill...

  9. Calorimetric investigation of (Pb0.45Bi0.55)-U system

    International Nuclear Information System (INIS)

    Agarwal, Renu; Samui, Pradeep; Mukerjee, S.K.; Ramakumar, K.L.

    2016-01-01

    Lead-bismuth eutectic (LBE) is being considered as a coolant of future high temperature reactors. As lead and bismuth are good spallation target material, they are planned to be used in accelerator driven reactor systems (ADS). Under the clad breach conditions these elements may come in direct contact with uranium of metallic fuel. In our labs, we had earlier investigated binary interactions of U-Pb and U-Bi. To assess interaction behaviour of 'U' with the eutectic melt, it was planned to measure enthalpy of mixing of LBE-U and compares it with the binary mixing. SEM-EDS studies of the product formed after mixing of LBE and 'U' were carried out to establish coexisting phases and their compositions. UPb 3 is Pb-rich compound of U-Pb and UBi 2 is Bi-rich compound of U-Bi. So addition of 'U' in (Pb 0.45 Bi 0.55 ) will result in formation of the more stable compound among UPb 3 and UBi 2

  10. Mechanical Properties and Real-Time Damage Evaluations of Environmental Barrier Coated SiC/SiC CMCs Subjected to Tensile Loading Under Thermal Gradients

    Science.gov (United States)

    Appleby, Matthew; Zhu, Dongming; Morscher, Gregory

    2015-01-01

    SiC/SiC ceramic matrix composites (CMCs) require new state-of-the art environmental barrier coatings (EBCs) to withstand increased temperature requirements and high velocity combustion corrosive combustion gasses. The present work compares the response of coated and uncoated SiC/SiC CMC substrates subjected to simulated engine environments followed by high temperature mechanical testing to asses retained properties and damage mechanisms. Our focus is to explore the capabilities of electrical resistance (ER) measurements as an NDE technique for testing of retained properties under combined high heat-flux and mechanical loading conditions. Furthermore, Acoustic Emission (AE) measurements and Digital Image Correlation (DIC) were performed to determine material damage onset and accumulation.

  11. Phase evolution and dielectric properties of MgTi2O5 ceramic sintered with lithium borosilicate glass

    International Nuclear Information System (INIS)

    Shin, Hyunho; Shin, Hee-Kyun; Jung, Hyun Suk; Cho, Seo-Yong; Hong, Kug Sun

    2005-01-01

    Phase evolution, densification, and dielectric properties of MgTi 2 O 5 dielectric ceramic, sintered with lithium borosilicate (LBS) glass, were studied. Reaction between LBS glass and MgTi 2 O 5 was significant in forming secondary phases such as TiO 2 and (Mg,Ti) 2 (BO 3 )O. The glass addition was not necessarily deleterious to the dielectric properties due to the formation of TiO 2 : permittivity increased and temperature coefficient of resonance frequency could be tuned to zero with the addition of LBS glass, although the inevitable glass-induced decrease of quality factor was not retarded by the formation of TiO 2 . The sintered specimen with 10 wt% LBS fired at 950 deg. C for 2 h showed permittivity of 19.3, quality factor of 6800 GHz, and τ f of -16 ppm/ deg. C

  12. Reprogramming neutral lipid metabolism in mouse dendritic leucocytes hosting live Leishmania amazonensis amastigotes.

    Directory of Open Access Journals (Sweden)

    Hervé Lecoeur

    Full Text Available BACKGROUND: After loading with live Leishmania (L amazonensis amastigotes, mouse myeloid dendritic leucocytes/DLs are known to undergo reprogramming of their immune functions. In the study reported here, we investigated whether the presence of live L. amazonensis amastigotes in mouse bone marrow-derived DLs is able to trigger re-programming of DL lipid, and particularly neutral lipid metabolism. METHODOLOGY/PRINCIPAL FINDINGS: Affymetrix-based transcriptional profiles were determined in C57BL/6 and DBA/2 mouse bone marrow-derived DLs that had been sorted from cultures exposed or not to live L. amazonensis amastigotes. This showed that live amastigote-hosting DLs exhibited a coordinated increase in: (i long-chain fatty acids (LCFA and cholesterol uptake/transport, (ii LCFA and cholesterol (re-esterification to triacyl-sn-glycerol (TAG and cholesteryl esters (CE, respectively. As these neutral lipids are known to make up the lipid body (LB core, oleic acid was added to DL cultures and LB accumulation was compared in live amastigote-hosting versus amastigote-free DLs by epi-fluorescence and transmission electron microscopy. This showed that LBs were both significantly larger and more numerous in live amastigote-hosting mouse dendritic leucocytes. Moreover, many of the larger LB showed intimate contact with the membrane of the parasitophorous vacuoles hosting the live L. amazonensis amastigotes. CONCLUSIONS/SIGNIFICANCE: As leucocyte LBs are known to be more than simple neutral lipid repositories, we set about addressing two related questions. Could LBs provide lipids to live amastigotes hosted within the DL parasitophorous vacuole and also deliver? Could LBs impact either directly or indirectly on the persistence of L. amazonensis amastigotes in rodent skin?

  13. Measurements of loop antenna loading in RF heating experiments on the KT-5C tokamak

    International Nuclear Information System (INIS)

    Zhai Kan; Deng Bihe; Wen Yizhi; Wan Shude; Liu Wandong; Yu Wen; Yu Changxun

    1997-01-01

    A new method to measure the loop antenna loadings in the RF wave heating experiments (IBWH at reasonable RF power with relatively low frequency) on the KT-5C device is presented. The method is characterized by determining the RF current ratio only, so it eases the needs of instruments and simplifies the requirements for calibration and data processing in the experiments

  14. Serendipitous SEU hardening of resistive load SRAMs

    International Nuclear Information System (INIS)

    Koga, R.; Kirshman, J.F.; Pinkerton, S.D.; Hansel, S.J.; Crawford, K.B.; Crain, W.R.

    1996-01-01

    High and low resistive load versions of Micron Technology's MT5C1008C (128K x 8) and MT5C2561C (256K x 1) SRAMs were tested for SEU vulnerability. Contrary to computer simulation results, SEU susceptibility decreased with increasing resistive load. A substantially larger number of multiple-bit errors were observed for the low resistive load SRAMs, which also exhibited a 1 → 0 to 0 → 1 bit error ratio close to unity; in contrast, the high resistive load devices displayed a pronounced error bit polarity effect. Two distinct upset mechanisms are proposed to account for these observations

  15. Load theory behind the wheel; perceptual and cognitive load effects.

    Science.gov (United States)

    Murphy, Gillian; Greene, Ciara M

    2017-09-01

    Perceptual Load Theory has been proposed as a resolution to the longstanding early versus late selection debate in cognitive psychology. There is much evidence in support of Load Theory but very few applied studies, despite the potential for the model to shed light on everyday attention and distraction. Using a driving simulator, the effect of perceptual and cognitive load on drivers' visual search was assessed. The findings were largely in line with Load Theory, with reduced distractor processing under high perceptual load, but increased distractor processing under high cognitive load. The effect of load on driving behaviour was also analysed, with significant differences in driving behaviour under perceptual and cognitive load. In addition, the effect of perceptual load on drivers' levels of awareness was investigated. High perceptual load significantly increased inattentional blindness and deafness, for stimuli that were both relevant and irrelevant to driving. High perceptual load also increased RTs to hazards. The current study helps to advance Load Theory by illustrating its usefulness outside of traditional paradigms. There are also applied implications for driver safety and roadway design, as the current study suggests that perceptual and cognitive load are important factors in driver attention. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  16. Misfit dislocations of anisotropic magnetoresistant Nd0.45Sr0.55MnO3 thin films grown on SrTiO3 (1 1 0) substrates

    International Nuclear Information System (INIS)

    Tang, Y.L.; Zhu, Y.L.; Meng, H.; Zhang, Y.Q.; Ma, X.L.

    2012-01-01

    Nd 0.45 Sr 0.55 MnO 3 is an A-type antiferromagnetic manganite showing obvious angular-dependent magnetoresistance, which can be tuned by misfit strain. The misfit strain relaxation of Nd 0.45 Sr 0.55 MnO 3 thin films is of both fundamental and technical importance. In this paper, microstructures of epitaxial Nd 0.45 Sr 0.55 MnO 3 thin films grown on SrTiO 3 (1 1 0) substrates by pulsed laser deposition were investigated by means of (scanning) transmission electron microscopy. The Nd 0.45 Sr 0.55 MnO 3 thin films exhibit a two-layered structure: a continuous perovskite layer epitaxial grown on the substrate followed by epitaxially grown columnar nanostructures. An approximately periodic array of misfit dislocations is found along the interface with line directions of both 〈1 1 1〉 and [0 0 1]. High-resolution (scanning) transmission electron microscopy reveals that all the misfit dislocations possess a〈1 1 0〉-type Burgers vectors. A formation mechanism based on gliding or climbing of the dislocations is proposed to elucidate this novel misfit dislocation configuration. These misfit dislocations have complex effects on the strain relaxation and microstructure of the films, and thus their influence needs further consideration for heteroepitaxial perovskite thin film systems, especially for films grown on substrates with low-symmetry surfaces such as SrTiO 3 (1 1 0) and (1 1 1), which are attracting attention for their potentially new functions.

  17. The repetition timing of high frequency afferent stimulation drives the bidirectional plasticity at central synapses in the rat medial vestibular nuclei.

    Science.gov (United States)

    Scarduzio, M; Panichi, R; Pettorossi, V E; Grassi, S

    2012-10-25

    In this study we show that high frequency stimulation (HFS, 100Hz) of afferent fibers to the medial vestibular nucleus (MVN) can induce opposite long-term modifications of synaptic responses in the type B neurons depending upon the stimulation pattern. Long burst stimulation (LBS: 2s) and short burst stimulation (SBS: 0.55s) were applied with different burst number (BN) and inter-burst intervals (IBI). It results that both LBS and SBS can induce either N-methyl-d aspartate receptors (NMDARs)-mediated long-term potentiation (LTP) or long-term depression (LTD), depending on temporal organization of repetitive bursts. In particular, the IBI plays a relevant role in guiding the shift from LTP to LTD since by using both LBS and SBS LTP is induced by shorter IBI than LTD. By contrast, the sign of long-term effect does not depend on the mean impulse frequency evaluated within the entire stimulation period. Therefore, the patterns of repetitive vestibular activation with different ratios between periods of increased activity and periods of basal activity may lead to LTP or LTD probably causing different levels of postsynaptic Ca(2+). On the whole, this study demonstrates that glutamatergic vestibular synapse in the MVN can undergo NMDAR-dependent bidirectional plasticity and puts forward a new aspect for understanding the adaptive and compensatory plasticity of the oculomotor responses. Copyright © 2012 IBRO. Published by Elsevier Ltd. All rights reserved.

  18. Structural Flight Loads Simulation Capability. Volume I.

    Science.gov (United States)

    1980-11-01

    actuators. Load cells sense the resulting loads and give the console operator a positive readout of the loads being applied. The operator’s console...qialn StesSa We Elmn 57. .......... C ’D D .... .. .-- --- -.. ... . ..114 .. ETF’ ’IFEFI,--EIJT :_I’F3L- EL4 ?O cl l c...3.20. (concluded). 127 ra E j214 CbC ob) C-H ea) 4p U) ’-4 r4 128 EL4 UA f r c www aw r. 0 ag 0 . 0 mo > 4-) 0 .4-) en 010 44 1*5 1 I .IA U * . a) Z

  19. [Optimization on trehalose loading technique as protective conditioning for lyophilization of human platelets].

    Science.gov (United States)

    Liu, Jing-Han; Zhou, Jun; Ouyang, Xi-Lin; Li, Xi-Jin; Lu, Fa-Qiang

    2005-08-01

    This study was aimed to further optimize trehalose loading technique including loading temperature, loading time, loading solution and loading concentration of trehalose, based on the established parameters. Loading efficiency in plasma was compared with that in buffer at 37 degrees C; the curves of intracellular trehalose concentration versus loading time at 37 degrees C and 16 degrees C were measured; curves of mean platelet volume (MPV) versus loading time and loading concentration were investigated and compared. According to results obtained, the loaing time, loading temperature, loading solution and trehalose concentration were ascertained for high loading efficiency of trehalose into human platelet. The results showed that the loading efficiency in plasma was markedly higher than that in buffer at 37 degrees C, the loading efficiency in plasma at 37 degrees C was significantly higher than that at 16 degrees C and reached 19.51% after loading for 4 hours, but 6.16% at 16 degrees C. MPV at 16 degrees C was increased by 43.2% than that at 37 degrees C, but had no distinct changes with loading time and loading concentration. In loading at 37 degrees C, MPV increased with loading time and loading concentration positively. Loading time and loading concentration displayed synergetic effect on MPV. MPV increased with loading time and concentration while trehalose loading concentration was above 50 mmol/L. It is concluded that the optimization parameters of trehalose loading technique are 37 degrees C (temperature), 4 hours (leading time), plasma (loading solution), 50 mmol/L (feasible trehalose concentration). The trehalose concentration can be adjusted to meet the requirement of lyophilization.

  20. High-pressure high-temperature stability of hcp-IrxOs1-x (x = 0.50 and 0.55) alloys

    Energy Technology Data Exchange (ETDEWEB)

    Yusenko, Kirill V.; Bykova, Elena; Bykov, Maxim; Gromilov, Sergey A.; Kurnosov, Alexander V.; Prescher, Clemens; Prakapenka, Vitali B.; Crichton, Wilson A.; Hanfland, Michael; Margadonna, Serena; Dubrovinsky, Leonid S.

    2016-12-23

    Hcp-Ir0.55Os0.45 and hcp-Ir0.50Os0.50 alloys were synthesised by thermal decomposition of single-source precursors in hydrogen atmosphere. Both alloys correspond to a miscibility gap in the Ir–Os binary phase diagram and therefore are metastable at ambient conditions. An in situ powder X-ray diffraction has been used for a monitoring a formation of hcp-Ir0.55Os0.45 alloy from (NH4)2[Ir0.55Os0.45Cl6] precursor. A crystalline intermediate compound and nanodimentional metallic particles with a large concentration of defects has been found as key intermediates in the thermal decomposition process in hydrogen flow. High-temperature stability of titled hcp-structured alloys has been investigated upon compression up to 11 GPa using a multi-anvil press and up to 80 GPa using laser-heated diamond-anvil cells to obtain a phase separation into fcc + hcp mixture. Compressibility curves at room temperature as well as thermal expansion at ambient pressure and under compression up to 80 GPa were collected to obtain thermal expansion coefficients and bulk moduli. hcp-Ir0.55Os0.45 alloy shows bulk moduli B0 = 395 GPa. Thermal expansion coefficients were estimated as α = 1.6·10-5 K-1 at ambient pressure and α = 0.3·10-5 K-1 at 80 GPa. Obtained high-pressure high-temperature data allowed us to construct the first model for pressure-dependent Ir–Os phase diagram.

  1. Effect of thermal annealing on electron spin relaxation of beryllium-doped In{sub 0.8}Ga{sub 0.2}As{sub 0.45}P{sub 0.55} bulk

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Hao; Harasawa, Ryo; Yasue, Yuya; Aritake, Takanori; Jiang, Canyu; Tackeuchi, Atsushi, E-mail: atacke@waseda.jp [Department of Applied Physics, Waseda University, Shinjuku, Tokyo 169-8555 (Japan); Ji, Lian; Lu, Shulong [Suzhou Institute of Nano-tech and Nano-bionics, Chinese Academy of Sciences, Dushu Lake Higher Education Town, Ruoshui Road 398, Suzhou Industrial Park, Suzhou (China)

    2016-08-15

    The effect of thermal annealing on the electron spin relaxation of beryllium-doped In{sub 0.8}Ga{sub 0.2}As{sub 0.45}P{sub 0.55} bulk was investigated by time-resolved spin-dependent pump and probe reflection measurement with a high time resolution of 200 fs. Three similar InGaAsP samples were examined one of which was annealed at 800 °C for 1 s, one was annealed at 700 °C for 1 s and the other was not annealed after crystal growth by molecular beam epitaxy. Although the carrier lifetimes of the 700 °C-annealed sample and the unannealed sample were similar, that of the 800 °C-annealed sample was extended to 11.6 (10.4) ns at 10 (300) K, which was more than two (four) times those of the other samples. However, interestingly the spin relaxation time of the 800 °C-annealed sample was found to be similar to those of the other two samples. Particularly at room temperature, the spin relaxation times are 143 ps, 147 ps, and 111 ps for the 800 °C-annealed sample, 700 °C-annealed sample, and the unannealed sample, respectively.

  2. Two gap superconductivity in Ba{sub 0.55}K{sub 0.45}Fe{sub 2}As{sub 2} single crystals studied by the directional point-contact Andreev reflection spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Szabo, P.; Pribulova, Z. [Centre of Low Temperature Physics, IEP Slovak Academy of Sciences and P.J.Safarik University, Watsonova 47, SK-04001 Kosice (Slovakia); Pristas, G.; Bud' ko, S.L.; Canfield, P.C. [Ames Laboratory and Iowa State University, Ames, IA 50011 (United States); Samuely, P., E-mail: samuely@saske.s [Centre of Low Temperature Physics, IEP Slovak Academy of Sciences and P.J.Safarik University, Watsonova 47, SK-04001 Kosice (Slovakia)

    2009-10-15

    First directional point-contact Andreev reflection spectroscopy on the Ba{sub 0.55}K{sub 0.45}Fe{sub 2}As{sub 2} single crystals is presented. The spectra show significant differences when measured in the ab plane in comparison with those measured in the c direction. In the latter case no traces of superconducting energy gap could be found, just a reduced point-contact conductance persisting up to about 100 K and indicating reduced density of states. On the other hand within the ab plane two nodeless superconducting energy gaps DELTA{sub S}approx2-5 meV and DELTA{sub L}approx9-11 meV are detected.

  3. Serum cystatin C concentration measured routinely is a prognostic marker for renal disease in dogs.

    Science.gov (United States)

    Iwasa, Naoki; Takashima, Satoshi; Iwasa, Tatsuo; Iwasa, Kazuko; Suzuki, Tomomi; Kobatake, Yui; Kitagawa, Hitoshi; Nishii, Naohito

    2018-06-14

    This study examined the predictive value of serum cystatin C (Cys-C) concentration, measured during routine periodic health examinations, in the renal prognosis of dogs. A cohort of 140 dogs weighing C concentrations were measured during periodic health examinations from December 2013 to March 2016 were prospectively studied, with renal disease-related death the predicted end point. Of the 140 dogs, nine died from renal diseases during the follow-up period (539 ± 249 days). Serum Cys-C concentrations were higher in the dogs that subsequently died of renal disease than in the censored group (0.8 ± 0.25 vs. 0.3 ± 0.1 mg/dl, respectively; P C concentrations (>0.55 mg/dl) had a shorter (P C concentrations (≤0.55 mg/dl). In conclusion, high serum Cys-C concentrations in periodic health examinations in dogs <15 kg predicted poorer prognosis for renal function. Copyright © 2018. Published by Elsevier Ltd.

  4. Eddy-current testing of fatigue degradation upon contact fatigue loading of gas powder laser clad NiCrBSi-Cr3C2 composite coating

    Science.gov (United States)

    Savrai, R. A.; Makarov, A. V.; Gorkunov, E. S.; Soboleva, N. N.; Kogan, L. Kh.; Malygina, I. Yu.; Osintseva, A. L.; Davydova, N. A.

    2017-12-01

    The possibilities of the eddy-current method for testing the fatigue degradation under contact loading of gas powder laser clad NiCrBSi-Cr3C2 composite coating with 15 wt.% of Cr3C2 additive have been investigated. It is shown that the eddy-current testing of the fatigue degradation under contact loading of the NiCrBSi-15%Cr3C2 composite coating can be performed at high excitation frequencies 72-120 kHz of the eddy-current transducer. At that, the dependences of the eddy-current instrument readings on the number of loading cycles have both downward and upward branches, with the boundary between the branches being 3×105 cycles in the given loading conditions. This is caused, on the one hand, by cracking, and, on the other hand, by cohesive spalling and compaction of the composite coating, which affect oppositely the material resistivity and, correspondingly, the eddy-current instrument readings. The downward branch can be used to monitor the processes of crack formation and growth, the upward branch - to monitor the degree of cohesive spalling, while taking into account in the testing methodology an ambiguous character of the dependences of the eddy-current instrument readings on the number of loading cycles.

  5. Nuclear Aircraft Feasibility Study. Volume 1

    Science.gov (United States)

    1975-03-01

    Iso Dose 10-12 10.1.4-3 Absorption Cross Section Ratio 10-14 10.1.5-1 Engine Systems Study Diagram 10-15 10.1.8-1 Life Cycle Cost for 60...0 00 ■ 3 15.00 OC z ^ 10.00 X s -i 1 UJ 5 < oc D I 50.00 40.00 30.00 20.00 1 ’ ISO LBS/SQ FT WING...4.1.6-1. Payload vs Wing Loading 4-17 m I - 27000 | i i ^1 ̂ N GROSS WEIGHT > 1.600,000 LBS 523 FT/SEC P 30.000 FT ONE GAS REACTOR 1

  6. Serum Anti-Vibrio cholerae Immunoglobulin Isotype in BALB/c Mice Immunized With ompW-Loaded Chitosan

    Directory of Open Access Journals (Sweden)

    Mahdi Fasihi-Ramandi

    2016-05-01

    Full Text Available Background: Chitosan, a liner polysaccharide, is a biocompatible and safe material for the delivery of therapeutic proteins and antigens, particularly via mucosal systems. Objectives: In this study, the production of antibodies in response to outermembrane protein W (ompW-loaded chitosan in BALB/c mice was evaluated. Materials and Methods: Mice were subjected to intraperitoneal injection of ompW or nasal administration of ompW-loaded chitosan on days 1, 14, and 28, and the antibodies were measured on day 42 with ELISA. Results: The titration of antibodies indicated that the nasal administration of ompW-loaded chitosan was better able to stimulate the immune response compared to intraperitoneal injections. However, the titration of total and IgG isotypes showed a significant difference between intraperitoneal and nasal immunization (P < 0.01. A significant difference was also seen in serum IgA isotypes at over 1/80 titrations, but not at lower dilutions (P < 0.01. Despite the serum antibodies, the results of lavage fluid analysis revealed that the IgG and IgA isotypes in the mice subjected to nasal immunization with ompW-loaded chitosan were significantly higher than in the other group (P < 0.01. Conclusions: Based on the preliminary results presented in this research, it is suggested that ompW-loaded chitosan could be a suitable choice for nasal application to immunize the host against Vibrio cholerae. However, more work is required to determine the efficiency of the antibodies in neutralizing the bacterial toxin or bacterial movement.

  7. Calculation of neutron shielding for a real loaded C-30 cask by code DORT

    International Nuclear Information System (INIS)

    Lacina, J.

    1999-01-01

    Measured neutron dose rates of real loaded C-30 casks for WWER spent fuel assemblies are compared with calculated values in the frame of benchmark calculation task. The part of this benchmark task concerning neutron shielding was calculated. Neutron sources values were taken from data presented by V. Chrapciak during the eighth symposium Atomic Energy Research, Bystrice pod Perstejnem in 1998 and the data about cask from the article of the same author from the Atomic Energy Research working group E meeting at Stolpen in 1998. (Author)

  8. Distribution of iron during full loading of amberlite IRC-72 resin with uranium from nitrate solutions at 300C

    International Nuclear Information System (INIS)

    Shaffer, J.H.; Greene, C.W.

    1979-01-01

    The integrity of resin-based fuel kernels used in the fabrication of fuel elements for a high-temperature gas-cooled reactor will depend, in part, on the concentration of iron incorporated in the resin particles during their loading with uranium. Consequently, assessment of chemical specifications for iron as an impurity in uranyl nitrate solution should be based on its distribution during the resin loading operation. For this purpose, the behavior of iron, as an impurity in uranyl nitrate solutions, was investigated under equilibrium conditions at 30 0 C during full loading of Amberlite IRC-72 cation exchange reaction were derived from calculations based on complex coordination of ferric ion with the resin over the nitrate ion concentration range of approx. 0.5 to 2 N

  9. 28 CFR 0.55 - General functions.

    Science.gov (United States)

    2010-07-01

    ... Administration Act, the Federal Seed Act, the Gold Reserve Act of 1934, the Hours of Service Act, the Animal... (18 U.S.C. 1761-1762), the Safety Appliance Act, standard barrels (15 U.S.C. 231-242), the Sugar Act... Judicial Administration DEPARTMENT OF JUSTICE ORGANIZATION OF THE DEPARTMENT OF JUSTICE Criminal Division...

  10. Impaired phloem loading in zmsweet13a,b,c sucrose transporter triple knock-out mutants in Zea mays.

    Science.gov (United States)

    Bezrutczyk, Margaret; Hartwig, Thomas; Horschman, Marc; Char, Si Nian; Yang, Jinliang; Yang, Bing; Frommer, Wolf B; Sosso, Davide

    2018-04-01

    Crop yield depends on efficient allocation of sucrose from leaves to seeds. In Arabidopsis, phloem loading is mediated by a combination of SWEET sucrose effluxers and subsequent uptake by SUT1/SUC2 sucrose/H + symporters. ZmSUT1 is essential for carbon allocation in maize, but the relative contribution to apoplasmic phloem loading and retrieval of sucrose leaking from the translocation path is not known. Here we analysed the contribution of SWEETs to phloem loading in maize. We identified three leaf-expressed SWEET sucrose transporters as key components of apoplasmic phloem loading in Zea mays L. ZmSWEET13 paralogues (a, b, c) are among the most highly expressed genes in the leaf vasculature. Genome-edited triple knock-out mutants were severely stunted. Photosynthesis of mutants was impaired and leaves accumulated high levels of soluble sugars and starch. RNA-seq revealed profound transcriptional deregulation of genes associated with photosynthesis and carbohydrate metabolism. Genome-wide association study (GWAS) analyses may indicate that variability in ZmSWEET13s correlates with agronomical traits, especifically flowering time and leaf angle. This work provides support for cooperation of three ZmSWEET13s with ZmSUT1 in phloem loading in Z. mays. © 2018 The Authors. New Phytologist © 2018 New Phytologist Trust.

  11. Hybrid fibre-reinforced concrete under repeated loading

    International Nuclear Information System (INIS)

    Komlos, K.; Babal, B.; Nuernbergerova, T.

    1995-01-01

    Fibre-reinforced concrete containing several volume fractions in different ratios of two types of fibre - polypropylene and steel - were tested under repeated loading. The mechanical properties of specimens - cubes 150mm x 150mm x 150mm (for compressive strength), prisms 100mm x 100mm x 400mm (for flexural strength) and short cylinders 150mm long and 60mm in diameter (for impact strength) - have been experimentally investigated before and after cyclic loading after a curing time of 28 days.Mix proportions were designed according to DIN 1045 with maximum aggregate size 8mm and grading curve B8. Portland cement PC 40 in the amount of 450kgm -3 was applied and the water-to-cement ratio was 0.55. The workability of mixes was measured by the Vebe method and regulated by the plasticizing admixture Ligoplast Na. The maximum hybrid fibre volume fraction (polypropylene+steel) was 1.0%. The dynamic forces generated in a Schenck testing machine with a frequency of 16Hz had a sinusoidal waveform varying between 0.7 and 0.1 of the static mechanical characteristics. The number of cycles in all tests was 10 5 . The residual MOR in the static four-point bending test and working force-deflection diagram were also obtained. The impact properties after repeated loading in compression were tested by means of the falling-weight test. Relationships between the composition of fibre composites with different amounts of polypropylene (0.2, 0.3 and 0.5vol.%) and steel fibre content (0.5, 0.7 and 0.8vol.%) were obtained and the technological properties of the mixes as well. (orig.)

  12. Dicty_cDB: Contig-U03742-1 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available H240-264L12, WORKING DRAFT SEQU... 48 0.55 1 ( FK748225 ) av01025l02r1.1 Symbiotic sea anemone (Anemonia vi...... 48 0.55 1 ( FK733073 ) av01027g09r1.1 Symbiotic sea anemone (Anemonia vi... 48

  13. Behavior and failure of uniformly hydrided Zircaloy-4 fuel claddings between 25 C and 480 C under various stress states, including RIA loading conditions

    International Nuclear Information System (INIS)

    Le Saux, M.; Carassou, S.; Averty, X.; Le Saux, M.; Besson, J.; Poussard, C.

    2010-01-01

    The anisotropic plastic behavior and the fracture of as-received and hydrided Cold-Worked Stress Relieved Zircaloy-4 cladding tubes are investigated under thermal-mechanical loading conditions representative of Pellet-Clad Mechanical Interaction during Reactivity Initiated Accidents in Pressurized Water Reactors. In order to study the combined effects of temperature, hydrogen content, loading direction and stress state, Axial Tensile, Hoop Tensile, Expansion Due to Compression and hoop Plane Strain Tensile tests are performed at room temperature, 350 C and 480 C on the material containing various hydrogen contents up to 1200 wt. ppm (hydrides are circumferential and homogeneously distributed). These tests are combined with digital image correlation and metallographic and fractographic observations at different scales. The flow stress of the material decreases with increasing temperature. The material is either strengthened or softened by hydrogen depending on temperature and hydrogen content. Plastic anisotropy depends on temperature but not on hydrogen content. The ductility of the material decreases with increasing hydrogen content at room temperature due to damage nucleation by hydride cracking. The plastic strain that leads to hydride fracture at room temperature decreases with increasing hydrogen content. The influence of stress triaxiality on hydride cracking is negligible in the studied range. The influence of hydrogen on material ductility is negligible at 350 C and 480 C since hydrides do not crack at these temperatures. The ductility of the material increases with increasing temperature. The evolution of material ductility is associated with a change in both the macroscopic fracture mode of the specimens and the microscopic failure mechanisms. (authors)

  14. Sistem Informasi Geografis Asrama Mahasiswa Aceh Berbasis LBS (Location Based Service “Saweue Syedara” Berbasis Android

    Directory of Open Access Journals (Sweden)

    Alwie Augusra T. A

    2015-01-01

    Full Text Available Student Dormitory is a desirable place to live for all overseas Aceh students that far from home, Student Dormitory be exclusive if the existence of a dormitory is located very far from the government and from the student's hometown, so the presence of dormitory is felt not exist and far from elegant impression , there are many Aceh students dormitory are not recorded by the Regional Government , that recorded only dormitory under the auspices of the government, when in fact the most dormitory are located under other institutions. Along with the development of, make it even easier people's lives in their daily live. During its development, mobile technology can determine the position of users, find the location you want to target, and provide a route to that location. The use of mobile devices for the Aceh Government, Society, and students in particular is to facilitate them in the course of a visit to Student Dormitory. The geographic information system created using the Java programming language with SDK (Software Development Kit Android and using MySQL and SQLite databases, the system is a client-server. The process of making and development of Geographic Information System using SDLC (Software Development Life Cycle using prototyping life cycle. By using the life cycle of prototyping, the design can be quickly created and tested by users. Users can participate in helping the development of a system to provide feedback on the prototype that has been tried before, so that the system be made better. The result of this application design is the realization of a mobile application that can allow users to find information and search for Aceh Student Dormitory in Java Island, Indonesia. The Geographic Information System uses technology of LBS (Location Based Service, this allows users to find the location of dormitory that wish to visit. This system will be developed on mobile devices using the Android operating system.

  15. MEASUREMENT OF WASTE LOADING IN SALTSTONE

    International Nuclear Information System (INIS)

    Harbour, J; Vickie Williams, V

    2008-01-01

    One of the goals of the Saltstone variability study is to identify the operational and compositional variables that control or influence the important processing and performance properties of Saltstone grout mixtures. One of those properties of importance is the Waste Loading (WL) of the decontaminated salt solution (DSS) in the Saltstone waste form. Waste loading is a measure of the amount of waste that can be incorporated within a waste form. The value of the Saltstone waste loading ultimately determines the number of vaults that will be required to disposition all of the DSS. In this report, the waste loading is defined as the volume in milliliters of DSS per liter of Saltstone waste form. The two most important parameters that determine waste loading for Saltstone are water to cementitious material (w/cm) ratio and the cured grout density. Data are provided that show the dependence of waste loading on the w/cm ratio for a fixed DSS composition using the current premix material (45% Blast Furnace Slag (BFS), 45% Fly Ash (FA) and 10% Ordinary Portland Cement (OPC)). The impact of cured grout density on waste loading was also demonstrated. Mixes (at 0.60 w/cm) made with a Modular Caustic side extraction Unit (MCU) simulant and either OPC or BFS have higher cured grout densities than mixes made with premix and increase the WL to 709 mL/L for the OPC mix and 689 mL/L for the BFS mix versus the value of 653 mL/L for MCU in premix at 0.60 w/cm ratio. Bleed liquid reduces the waste loading and lowers the effective w/cm ratio of Saltstone. A method is presented (and will be used in future tasks) for correcting the waste loading and the w/cm ratio of the as-batched mixes in those cases where bleed liquid is present. For example, the Deliquification, Dissolution and Adjustment (DDA) mix at an as-batched 0.60 w/cm ratio, when corrected for % bleed, gives a mix with a 0.55 w/cm ratio and a WL that has been reduced from 662 to 625 mL/L. An example is provided that

  16. HIV Viral Load

    Science.gov (United States)

    ... PF4 Antibody Hepatitis A Testing Hepatitis B Testing Hepatitis C Testing HER2/neu Herpes Testing High-sensitivity C-reactive Protein (hs-CRP) Histamine Histone Antibody HIV Antibody and HIV Antigen (p24) HIV Antiretroviral Drug Resistance Testing, Genotypic HIV Viral Load HLA Testing HLA- ...

  17. Impact of polymorphisms in the HCP5 and HLA-C, and ZNRD1 genes on HIV viral load

    DEFF Research Database (Denmark)

    Thørner, Lise Wegner; Erikstrup, Christian; Harritshøj, Lene Holm

    2016-01-01

    AIMS: Single nucleotide polymorphisms (SNPs) in the human leucocyte antigen (HLA) complex P5 (HCP5), HLA-C, and near the zinc ribbon domain containing 1 (ZNRD1) have been shown to influence viral load (VL) set point in HIV-infected individuals with a known seroconversion onset. We aimed to determ...

  18. Dicty_cDB: Contig-U05179-1 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available 07 AE000512_160( AE000512 |pid:none) Thermotoga maritima MSB8, comple... 59 3e-07 AM494956_53( AM494956 |pid...5462316567 Global-Ocean-Sampling_GS-31-01-01-1... 36 4.7 3 ( CU675067 ) Synthetic construct Homo sapiens gat...4 0.15 2 ( EK365242 ) 1095469394395 Global-Ocean-Sampling_GS-31-01-01-1... 50 0.19 1 ( DQ832718 ) Phytophtho... F... 38 0.55 2 ( EK172602 ) 1095458082313 Global-Ocean-Sampling_GS-31-01-01-1...... 34 0.55 2 ( EK226550 ) 1095460160991 Global-Ocean-Sampling_GS-31-01-01-1... 34 0.55 2 ( ES217923 ) MpFVN_ag2_E11 Myzus persicae, li

  19. IMPACT OF REDUCING THE 100 C LIQUIDUS TEMPERATURE OFFSET ON WASTE LOADING TARGETS

    Energy Technology Data Exchange (ETDEWEB)

    Peeler, D.; Edwards, T.

    2010-11-11

    The objective of this report is to assess the potential impact of reducing conservatism in the implementation of the current liquidus temperature (TL) model in the Product Composition Control System (PCCS) on the ability to target higher waste loadings (WLs) for future sludge batches. No changes to the TL model or the associated uncertainties (model or measurement) are proposed, rather only changes in the magnitude of the offset used between the nominal melt pool temperature (1150 C) and the Property Acceptance Region (PAR) value (1050 C). This strategy is consistent with that outlined and initially assessed by Brown et al. (2001). In that report, the authors stated even a fairly conservative change in this safety factor could have a significant impact on waste loading. The results of this study clearly indicate that the implementation of an 1100 C TL PAR criterion (which translates into a reduction in the TL offset from 100 C to 50 C) can have significantly positive impacts on the ability to gain access to WLs exceeding 45%. This is especially true for those frit and sludge systems that are TL limited using the current 1050 C TL criterion, and are not limited by a second constraint (such as viscosity, nepheline, or durability) until much higher WLs. Examples of various glass forming systems are provided that are currently limited to maximum WLs in the mid-40s, but could be processed in the lower 50s through implementation of this new strategy. One example is in the Sludge Batch 10 (SB10) system, where for a specific glass forming system the projected operating window of 38-41% WL (using the current constraints) became 38-52% WL with the use of an 1100 C TL PAR value. This change both provided access to significantly higher WLs, and transitioned a once infeasible flowsheet to a system that could potentially be processed in the Defense Waste Processing Facility (DWPF). This potential change in the TL constraint also provides access to frit compositions (or glass

  20. Sensitivity Analysis of Depletion Parameters for Heat Load Evaluation of PWR Spent Fuel Storage Pool

    International Nuclear Information System (INIS)

    Kim, In Young; Lee, Un Chul

    2011-01-01

    As necessity of safety re-evaluation for spent fuel storage facility has emphasized after the Fukushima accident, accuracy improvement of heat load evaluation has become more important to acquire reliable thermal-hydraulic evaluation results. As groundwork, parametric and sensitivity analyses of various storage conditions for Kori Unit 4 spent fuel storage pool and spent fuel depletion parameters such as axial burnup effect, operation history, and specific heat are conducted using ORIGEN2 code. According to heat load evaluation and parametric sensitivity analyses, decay heat of last discharged fuel comprises maximum 80.42% of total heat load of storage facility and there is a negative correlation between effect of depletion parameters and cooling period. It is determined that specific heat is most influential parameter and operation history is secondly influential parameter. And decay heat of just discharged fuel is varied from 0.34 to 1.66 times of average value and decay heat of 1 year cooled fuel is varied from 0.55 to 1.37 times of average value in accordance with change of specific power. Namely depletion parameters can cause large variation in decay heat calculation of short-term cooled fuel. Therefore application of real operation data instead of user selection value is needed to improve evaluation accuracy. It is expected that these results could be used to improve accuracy of heat load assessment and evaluate uncertainty of calculated heat load.

  1. Dicty_cDB: Contig-U15649-1 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available quence 40152 from patent US 7314974. 38 1e-04 4 ( DC238926 ) Hodotermopsis sjoestedti cDNA clone: MY0813AHsB...od... 62 1e-04 1 ( DC237244 ) Hodotermopsis sjoestedti cDNA clone: MY0680BHsMg_... 62 1e-04 1 ( FF293936 ) 2...ea aphid whole body normalized full le... 42 0.006 4 ( EJ520101 ) 1092955132614 Global-Ocean-Sampling_GS-29-...467043591 Global-Ocean-Sampling_GS-32-01-01-1... 44 0.025 2 ( DU736845 ) APKI3962.b2 HF70_10-07-02 uncultured...55 2 ( EK079306 ) 1092961088999 Global-Ocean-Sampling_GS-31-01-01-1... 36 0.055 4 ( FF866982 ) CBWU12396.b1 Yutaka Satou unpublished

  2. InAs0.45P0.55/InP strained multiple quantum wells intermixed by inductively coupled plasma etching

    International Nuclear Information System (INIS)

    Cao, Meng; Wu, Hui-Zhen; Lao, Yan-Feng; Cao, Chun-Fang; Liu, Cheng

    2009-01-01

    The intermixing effect on InAs 0.45 P 0.55 /InP strained multiple quantum wells (SMQWs) by inductively coupled plasma (ICP) etching and rapid thermal annealing (RTA) is investigated. Experiments show that the process of ICP etching followed RTA induces the blue shift of low temperature photoluminescence (PL) peaks of QWs. With increasing etching depth, the PL intensities are firstly enhanced and then diminished. This phenomenon is attributed to the variation of surface roughness and microstructure transformation inside the QW structure during ICP processing.

  3. Loads and loads and loads: The influence of prospective load, retrospective load, and ongoing task load in prospective memory

    Directory of Open Access Journals (Sweden)

    Beat eMeier

    2015-06-01

    Full Text Available In prospective memory tasks different kinds of load can occur. Adding a prospective memory task can impose a load on ongoing task performance. Adding ongoing task load can affect prospective memory performance. The existence of multiple target events increases prospective load and adding complexity to the to-be-remembered action increases retrospective load. In two experiments, we systematically examined the effects of these different types of load on prospective memory performance. Results showed an effect of prospective load on costs in the ongoing task for categorical targets (Experiment 2, but not for specific targets (Experiment 1. Retrospective load and ongoing task load both affected remembering the retrospective component of the prospective memory task. We suggest that prospective load can enhance costs in the ongoing task due to additional monitoring requirements. Retrospective load and ongoing task load seem to impact the division of resources between the ongoing task and retrieval of the retrospective component, which may affect disengagement from the ongoing task. In general, the results demonstrate that the different types of load affect prospective memory differentially.

  4. Characterization of Reduced Graphene Oxide (rGO-Loaded SnO2 Nanocomposite and Applications in C2H2 Gas Detection

    Directory of Open Access Journals (Sweden)

    Lingfeng Jin

    2016-12-01

    Full Text Available Acetylene (C2H2 gas sensors were developed by synthesizing a reduced graphene oxide (rGO-loaded SnO2 hybrid nanocomposite via a facile two-step hydrothermal method. Morphological characterizations showed the formation of well-dispersed SnO2 nanoparticles loaded on the rGO sheets with excellent transparency and obvious fold boundary. Structural analysis revealed good agreement with the standard crystalline phases of SnO2 and rGO. Gas sensing characteristics of the synthesized materials were carried out in a temperature range of 100–300 °C with various concentrations of C2H2 gas. At 180 °C, the SnO2–rGO hybrid showed preferable detection of C2H2 with high sensor response (12.4 toward 50 ppm, fast response-recovery time (54 s and 23 s, limit of detection (LOD of 1.3 ppm and good linearity, with good selectivity and long-term stability. Furthermore, the possible gas sensing mechanism of the SnO2–rGO nanocomposites for C2H2 gas were summarized and discussed in detail. Our work indicates that the addition of rGO would be effective in enhancing the sensing properties of metal oxide-based gas sensors for C2H2 and may make a contribution to the development of an excellent ppm-level gas sensor for on-line monitoring of dissolved C2H2 gas in transformer oil.

  5. Design loads, loading combinations and structural acceptance criteria for BWR containments in the United States

    International Nuclear Information System (INIS)

    Edwards, N.W.

    1979-01-01

    The definition of loads, loading combinations, and structural acceptance criteria used for the design and evaluation of BWR containments in the Unites States has become much more comprehensive over the past decade. The Mark I pressure suppression containment vessels were designed for a static design pressure, a design temperature, dead load and static equivalent earthquake. The current Mark III containments are being designed to accommodate many more loads such as safety relief valve discharge loads, and suppression pool hydrodynamic loadings associated with the steam condensation phenomena as well as pressure and temperature transients for a range of pipe break sizes. Consistent with the more comprehensive definition of loads and loading combinations, the ASME Code presently establishes structural acceptance criteria with different margins of safety by the definition of Service Level Assignments A, B, C and D. Acting in a responsible manner, United States utilities are currently evaluating and modifying existing containment vessels to account for the more detailed load definition and structural acceptance criteria. (orig.)

  6. Creep testing and creep loading experiments on friction stir welds in copper at 75 deg C

    International Nuclear Information System (INIS)

    Andersson, Henrik C.M.; Seitisleam, Facredin; Sandstroem, Rolf

    2007-08-01

    Specimens cut from friction stir welds in copper canisters for nuclear waste have been used for creep experiments at 75 deg C. The specimens were taken from a cross-weld position as well as heat affected zone and weld metal. The parent metal specimens exhibited longer creep lives than the weld specimens by a factor of three in time. They in turn were longer than those for the crossweld and HAZ specimens by an order of magnitude. The creep exponent was in the interval 50 to 69 implying that the material was well inside the power-law breakdown regime. The ductility properties expressed as reduction in area were not significantly different and all the rupture specimens demonstrated values exceeding 80%. Experiments were also carried out on the loading procedure of a creep test. Similar parent metal specimens and test conditions were used and the results show that the loading method has a large influence on the strain response of the specimen

  7. Creep testing and creep loading experiments on friction stir welds in copper at 75 deg C

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, Henrik C.M.; Seitisleam, Facredin; Sandstroem, Rolf [Corrosion an d Metals Research Institute, Stockholm (Sweden)

    2007-08-15

    Specimens cut from friction stir welds in copper canisters for nuclear waste have been used for creep experiments at 75 deg C. The specimens were taken from a cross-weld position as well as heat affected zone and weld metal. The parent metal specimens exhibited longer creep lives than the weld specimens by a factor of three in time. They in turn were longer than those for the crossweld and HAZ specimens by an order of magnitude. The creep exponent was in the interval 50 to 69 implying that the material was well inside the power-law breakdown regime. The ductility properties expressed as reduction in area were not significantly different and all the rupture specimens demonstrated values exceeding 80%. Experiments were also carried out on the loading procedure of a creep test. Similar parent metal specimens and test conditions were used and the results show that the loading method has a large influence on the strain response of the specimen.

  8. Several loadings and stresses of first wall of SiC with metal liner on conceptual design of moving ring reactor 'KARIN-1'

    International Nuclear Information System (INIS)

    Nishikawa, Masahiro; Tachibana, Eizaburo; Watanabe, Kenji; Fujiie, Yoichi.

    1983-01-01

    On conceptual design of moving ring reactor ''KARIN-I'' (Output: 1850 MWe), the first wall of SiC with metal liner is considered by reason that SiC ceramics has specific features of excellent radiation damage resistance in fast neutron spectra and a very low residual radioactivity, and that the thin metal liner has good compatibility with liquid lithium and good vaccum-tight, however, a extent electromagnetic interaction. The electromagnetic force applied on the metal liner and several pressure losses of liquid lithum flow are estimated, and these forces correspond to the fluid mechanical loading on SiC first wall. Thermal loading by neutron flux is calculated on the first wall to obtain temperature distributions along the flow direction and toward the wall thickness. At the outlet of the burning section, the surface temperature of SiC rises to the value of 825 0 C on plasma side and on the metal liner, it rises to the value of 540 0 C. Finally, the stress analysis is performed. The thermal stress is about one order larger than the stress induced by the fluid mechanical loading. At the inlet of the burning section, the average tensile stress of 22.4kg/mm 2 is induced on the outer side of SiC wall, and on the inner side, the average compressive stress of -26.1kg/mm 2 is induced. At the outlet of the burning section, the tensile stress is found to oscillate between 25.5kg/mm 2 and 27.3kg/mm 2 on the outer side of SiC wall by frequency of 1 Hz, and on the inner side, the compressive stress also oscillates between -21.6kg/mm 2 and -29.0kg/mm 2 by the same frequency. These stresses are within the value of fracture stress, (72.5kg/mm 2 ). Difficult residual problems on the first wall are also discussed. (author)

  9. Full scale test SSP 34m blade, edgewise loading LTT. Extreme load and PoC{sub I}nvE Data report

    Energy Technology Data Exchange (ETDEWEB)

    Nielsen, Magda; Roczek-Sieradzan, A.; Jensen, Find M. (and others)

    2010-09-15

    This report is the second report covering the research and demonstration project 'Experimental blade research: Structural mechanisms in current and future large blades under combined loading', supported by the EUDP program. A 34m wind turbine blade from SSP-Technology A/S has been tested in edgewise direction (LTT). The blade has been submitted to thorough examination by means of strain gauges, displacement transducers and a 3D optical measuring system. This data report presents results obtained during full scale testing of the blade up to 80% Risoe load, where 80% Risoe load corresponds to 100% certification load. These pulls at 80% Risoe load were repeated and the results from these pulls were compared. The blade was reinforced according to a Risoe DTU invention, where the trailing edge panels are coupled. The coupling is implemented to prevent the out of plane deformations and to reduce peeling stresses in the adhesive joints. Test results from measurements with the reinforcement have been compared to results without the coupling. The report presents only the relevant results for the 80% Risoe load and the results applicable for the investigation of the influence of the invention on the profile deformation. (Author)

  10. Structural, magnetic and magneto-transport properties of monovalent doped manganite Pr{sub 0.55}K{sub 0.05}Sr{sub 0.4}MnO{sub 3}

    Energy Technology Data Exchange (ETDEWEB)

    Thaljaoui, R., E-mail: thaljaoui@gmail.com [Laboratoire de Physique des Matériaux, Faculté des Sciences de Sfax, Université de Sfax, B.P. 1171, 3000 Sfax (Tunisia); Faculty of Physics, Warsaw University of Technology, Koszykowa 75, 00-662 Warsaw (Poland); Department of Chemistry, University of Warsaw, Al. Zwirki i Wigury 101, 02-089 Warsaw (Poland); Boujelben, W. [Laboratoire de Physique des Matériaux, Faculté des Sciences de Sfax, Université de Sfax, B.P. 1171, 3000 Sfax (Tunisia); Pękała, M. [Department of Chemistry, University of Warsaw, Al. Zwirki i Wigury 101, 02-089 Warsaw (Poland); Pękała, K.; Antonowicz, J. [Faculty of Physics, Warsaw University of Technology, Koszykowa 75, 00-662 Warsaw (Poland); Fagnard, J.-F.; Vanderbemden, Ph. [SUPRATECS, Department of Electrical Engineering and Computer Science (B28), University of Liege (Belgium); Dąbrowska, S. [Warsaw University of Technology, Faculty of Materials Science, ul. Wołoska 141, 02-507 Warsaw (Poland); Mucha, J. [Institute of Low Temperature Physics and Structural Research, 50-422 Wrocław (Poland)

    2014-10-25

    Highlights: • Investigation of a new monovalent doped manganite Pr{sub 0.55}K{sub 0.05}Sr{sub 0.4}MnO{sub 3}. • The stability of the sample has been carried by using the DTA analysis. • Magnetic entropy change around 2.26 J kg{sup −1} K{sup −1} resulting RCP value of 70 J/kg for an applied magnetic field of 2 T. • Second order phase transition is confirmed by Arrott plots: A and B Landau coefficients. • Thermal conductivity values are found to be higher for sample with the largest crystallite sizes. - Abstract: Pr{sub 0.55}K{sub 0.05}Sr{sub 0.4}MnO{sub 3} sample have been synthesized using the conventional solid state reaction. Rietveld refinements of the X-ray diffraction patterns at room temperature confirm that the sample is single phase and crystallizes in the orthorhombic structure with Pnma space group; the crystallite size is around 70 nm. The SEM images show that grain size spreads around 1000–1200 nm. DTA analysis does not reveal any clear transition in temperature range studied. The low-temperature DSC indicates that Curie temperature is around 297 K. Magnetization measurements in a magnetic applied field of 0.01 T exhibit a paramagnetic–ferromagnetic transition at the Curie temperature T{sub C} = 303 K. A magnetic entropy change under an applied magnetic field of 2 T is found to be 2.26 J kg{sup −1} K{sup −1}, resulting in a large relative cooling power around 70 J/kg. Electrical resistivity measurements reveal a transition from semiconductor to metallic phase. The thermal conductivity is found to be higher than that reported for undoped and Na doped manganites reported by Thaljaoui et al. (2013)

  11. Investigation on the behavioral difference in third order nonlinearity and optical limiting of Mn0.55Cu0.45Fe2O4 nanoparticles annealed at different temperatures

    Science.gov (United States)

    Yuvaraj, S.; Manikandan, N.; Vinitha, G.

    2017-11-01

    Mn0.55Cu0.45Fe2O4 nanoparticles were synthesized by wet chemical co-precipitation method. The obtained samples were annealed at different temperatures (500 °C to 1250 °C). All annealed samples were characterized for their structural, magnetic, linear and non-linear optical properties. XRD results confirm single phase cubic spinel structure only for samples annealed at 800 °C and 1250 °C. The average crystallite sizes of the samples are in the range of 11-37 nm. HR-SEM image of the sample annealed at 800 °C exposed spherical morphology. The quantitative analysis of EDX results is close to the expected values. Bandgaps were evaluated from UV-DRS. The FTIR spectrum showing the essential peaks around 452.1 and 567.2 cm-1 prove the formation of spinel nanoparticles. In PL spectrum, a broad emission peak is attained in visible region at 485 nm. The saturation magnetization (M s), coercivity (H c) and remanence magnetization (M r) are obtained from the hysteresis curve. Nonlinear absorption coefficients (10-4 cm W-1), nonlinear indices of refraction (10-8 cm2 W-1) and the third order nonlinear susceptibilities (10-6 esu) are determined using Z-scan experiment. CW laser beam is utilized to study the optical limiting characteristics and the results prove these materials to be a potential candidate for device applications like optical switches and power limiters.

  12. RF Loads for Energy Recovery

    CERN Document Server

    Federmann, S; Caspers, F

    2012-01-01

    Different conceptional designs for RF high power loads are presented. One concept implies the use of solid state rectifier modules for direct RF to DC conversion with efficiencies beyond 80%. In addition, robust metallic low-Q resonant structures, capable of operating at high temperatures (>150 ◦C) are discussed. Another design deals with a very high temperature (up to 800 ◦C) air cooled load using a ceramic foam block inside a metal enclosure. This porous ceramic block is the microwave absorber and is not brazed to the metallic enclosure.

  13. Advanced axial field D.C. motor development for electric passenger vehicle

    Science.gov (United States)

    Jones, W. J.

    1982-01-01

    A wound-field axial-flux dc motor was developed for an electric vehicle drive system. The motor is essentially an axial-flux version of the classical Gramme-ring winding motor, but the active conductors are recessed into slots cut into the two opposite faces of the laminated tape-wound core ring. Three motors were built and tested in the program. The second (functional) model was a six-pole machine which weighed 88.5 kg. It developed 16.9 km (33.0 hp), and a max speed of 4800 rpm. Full load efficiency was 92% and predicted SAE D-cycle efficiency was 88%. The last engineering) model was a 4-pole machine with compoles, allowing a weight reduction to 45 kg (100 lbs.) while addressing some manufacturability problems. The engineering model was rated at 13.2 kw (17.6 hp) at 3000 rpm, with a peak power of 19.8 km (26.4 hp) and a max speed of 7200 rpm. Initial test results on this motor showed poor commutation and efficiency; the program was terminated without resolution of these problems.

  14. Drug Loading of Mesoporous Silicon

    Science.gov (United States)

    Moffitt, Anne; Coffer, Jeff; Wang, Mengjia

    2011-03-01

    The nanostructuring of crystalline solids with low aqueous solubilities by their incorporation into mesoporous host materials is one route to improve the bioavailability of such solids. Earlier studies suggest that mesoporous Si (PSi), with pore widths in the range of 5-50 nm, is a candidate for such an approach. In this presentation, we describe efforts to load curcumin into free-standing microparticles of PSi. Curcumin is a compound extracted from turmeric root, which is an ingredient of curry. Curucmin has shown activity against selected cancer cell lines, bacteria, and other medical conditions. However, curcumin has a very low bioavailability due to its extremely low water solubility (0.6 μ g/mL). Incorporation of curcumin was achieved by straightforward loading of the molten solid at 185circ; C. Loading experiments were performed using PSi particles of two different size ranges, 45-75 μ m and 150-250 μ m. Longer loading times and ratio of curcumin to PSi leads to a higher percentage of loaded curcumin in both PSi particle sizes (as determined by weight difference). The extent of curcumin crystallinity was assessed by x-ray diffraction (XRD). The solubility and release kinetics of loaded curcumin from the PSi was determined by extraction into water at 37circ; C, with analysis using UV-VIS spectrometry. NSF-REU and TCU.

  15. Hetero-epitaxial growth of TiC films on MgO(001) at 100 °C by DC reactive magnetron sputtering

    International Nuclear Information System (INIS)

    Braic, M.; Zoita, N.C.; Danila, M.; Grigorescu, C.E.A.; Logofatu, C.

    2015-01-01

    Hetero-epitaxial TiC thin films were deposited at 100 °C on MgO(001) by DC reactive magnetron sputtering in a mixture of Ar and CH 4 . The 62 nm thick films were analyzed for elemental composition and chemical bonding by Auger electron spectroscopy, X-ray photoelectron spectroscopy and micro-Raman spectroscopy. The crystallographic structure investigation by high resolution X-ray diffraction revealed that the films consist of two layers: an interface partially strained epilayer with high crystalline quality, and a relaxed layer, formed by columnar grains, maintaining the epitaxial relationship with the substrate. The films presented smooth surfaces (RMS roughness ~ 0.55 nm), with circular equi-sized grains/crystallites, as observed by atomic force microscopy. The Hall measurements in Van der Pauw geometry revealed relatively high resistivity value ~ 620 μΩ cm, ascribed to electron scattering on interfaces, on grain boundaries and on different defects/dislocations. - Highlights: • Hetero-epitaxial TiC 0.84 thin films were grown on MgO(001) at 100 °C by magnetron sputtering. • 62 nm thick films were synthesized by magnetron sputtering, using Ti, Ar and CH 4 . • The film comprises a partially strained interface epilayer and a relaxed top layer. • Both layers preserve the epitaxial relationship with the substrate. • Low RMS surface roughness ~ 0.55 nm and grains with mean lateral size of ~ 38.5 nm were observed

  16. Hetero-epitaxial growth of TiC films on MgO(001) at 100 °C by DC reactive magnetron sputtering

    Energy Technology Data Exchange (ETDEWEB)

    Braic, M. [National Institute for Optoelectronics, 409 Atomistilor St., 077125 Magurele (Romania); Zoita, N.C., E-mail: cnzoita@inoe.ro [National Institute for Optoelectronics, 409 Atomistilor St., 077125 Magurele (Romania); Danila, M. [National Institute for Research and Development in Microtechnology, 126A Erou Iancu Nicolae Blvd., 077190 Bucharest (Romania); Grigorescu, C.E.A. [National Institute for Optoelectronics, 409 Atomistilor St., 077125 Magurele (Romania); Logofatu, C. [National Institute of Materials Physics, 105 bis Atomistilor St., 077125 Magurele (Romania)

    2015-08-31

    Hetero-epitaxial TiC thin films were deposited at 100 °C on MgO(001) by DC reactive magnetron sputtering in a mixture of Ar and CH{sub 4}. The 62 nm thick films were analyzed for elemental composition and chemical bonding by Auger electron spectroscopy, X-ray photoelectron spectroscopy and micro-Raman spectroscopy. The crystallographic structure investigation by high resolution X-ray diffraction revealed that the films consist of two layers: an interface partially strained epilayer with high crystalline quality, and a relaxed layer, formed by columnar grains, maintaining the epitaxial relationship with the substrate. The films presented smooth surfaces (RMS roughness ~ 0.55 nm), with circular equi-sized grains/crystallites, as observed by atomic force microscopy. The Hall measurements in Van der Pauw geometry revealed relatively high resistivity value ~ 620 μΩ cm, ascribed to electron scattering on interfaces, on grain boundaries and on different defects/dislocations. - Highlights: • Hetero-epitaxial TiC{sub 0.84} thin films were grown on MgO(001) at 100 °C by magnetron sputtering. • 62 nm thick films were synthesized by magnetron sputtering, using Ti, Ar and CH{sub 4}. • The film comprises a partially strained interface epilayer and a relaxed top layer. • Both layers preserve the epitaxial relationship with the substrate. • Low RMS surface roughness ~ 0.55 nm and grains with mean lateral size of ~ 38.5 nm were observed.

  17. Reciprocating Wear Behaviour of 7075Al/SiC and 6061Al/Al2O3 Composites: A study of Effect of Reinforcement, Stroke and Load

    Directory of Open Access Journals (Sweden)

    J. Lakshmipathy

    2014-06-01

    Full Text Available The wear behaviour comparison of Al/SiC and Al/Al2O3 composites prepared by stir casting technique is investigated to find out the effects of weight percentage of SiC/Al2O3, load and the number of strokes on a reciprocating wear testing machine. The MMC pins are prepared with different weight percentage of SiC and Al2O3 (10, 15 and 20 %. The tests are carried out with different load conditions (25, 50 and 75 N and different number of strokes (420,780 and 1605 strokes. Wear surfaces of tested samples are examined in Scanning Electron Microscope (SEM. Hardness test and impact test are also carried out on the MMC samples. The experimental results shows that hardness of composites increases with increase in SiC and Al2O3 particle and the impact strength decreases with increase in SiC and Al2O3 content. The volume loss of MMC specimens are less than that of the matrix alloy. The temperature rise near the contact surface of the MMC specimens increases with increase in wt% of SiC and Al2O3, load and number of strokes. The coefficient of friction decreases with increase in the number of strokes. The WVAS (Wireless Vibration Acquisition System interfaced with MAT Lab software is used to record the amplitudes during the test.

  18. On the thermal cyclic loading behaviour of a directional eutectic superalloy based on the Co-Cr-C system

    International Nuclear Information System (INIS)

    Hildebrandt, U.W.; Nicoll, A.R.

    1981-01-01

    Various modifications of the eutectic, directionally solidified superalloy 73 C were investigated with respect to creep fatigue effects. This was carried out using a thermal cycling apparatus where a mechanical uniaxial load could be applied. A high volume fraction of carbides had an impairing effect on fatigue life. An improvement, however, could be obtained using low concentrations of refractory elements which form monocarbides. (orig.) [de

  19. High Temperature Radio Frequency Loads

    CERN Document Server

    Federmann, S; Grudiev, A; Montesinos, E; Syratchev, I

    2011-01-01

    In the context of energy saving and recovery requirements the design of reliable and robust RF power loads which permit a high outlet temperature and high pressure of the cooling water is desirable. Cooling water arriving at the outlet withmore than 150 ◦C and high pressure has a higher value than water with 50 ◦C under low pressure. Conventional RF power loads containing dielectric and magnetic materials as well as sensitive ceramic windows usually do not permit going much higher than 90 ◦C. Here we present and discuss several design concepts for "metal only" RF high power loads. One concept is the application of magnetic steel corrugated waveguides near cutoff – this concept could find practical use above several GHz. Another solution are resonant structures made of steel to be installed in large waveguides for frequencies of 500 MHz or lower. Similar resonant structures above 100 MHz taking advantage of the rather high losses of normal steel may also be used in coaxial line geometries with large di...

  20. Cognitive load theory

    NARCIS (Netherlands)

    Kirschner, Paul A.; Kirschner, Femke; Paas, Fred

    2010-01-01

    Kirschner, P. A., Kirschner, F. C., & Paas, F. (2009). Cognitive load theory. In E. M. Anderman & L. H. Anderman (Eds.). Psychology of classroom learning: An encyclopedia, Volume 1, a-j (pp. 205-209). Detroit, MI: Macmillan Reference.

  1. Method for loading resin beds

    International Nuclear Information System (INIS)

    Notz, K.J.; Rainey, R.H.; Greene, C.W.; Shockley, W.E.

    1978-01-01

    An improved method of preparing nuclear reactor fuel by carbonizing a uranium loaded cation exchange resin provided by contacting a H+ loaded resin with a uranyl nitrate solution deficient in nitrate, comprises providing the nitrate deficient solution by a method comprising the steps of reacting in a reaction zone maintained between about 145 to 200 0 C, a first aqueous component comprising a uranyl nitrate solution having a boiling point of at least 145 0 C with a second aqueous component to provide a gaseous phase containing HNO 3 and a reaction product comprising an aqueous uranyl nitrate solution deficient in nitrate

  2. Heel blood flow during loading and off-loading in bedridden older adults with low and normal ankle-brachial pressure index: a quasi-experimental study.

    Science.gov (United States)

    Masaki, Nami; Sugama, Junko; Okuwa, Mayumi; Inagaki, Misako; Matsuo, Junko; Nakatani, Tosio; Sanada, Hiromi

    2013-07-01

    The purpose of this study was to evaluate the differences in heel blood flow during loading and off-loading in bedridden adults older than 65 years. The patients were divided into three groups based on ankle-brachial pressure index (ABI) and transcutaneous oxygen tension (tcPO₂): (1) patients with an ABI ≥ 0.8 (Group A); (2) patients with an ABI < 0.8 and heel tcPO₂ ≥ 10 mmHg (Group B); and (3) patients with an ABI < 0.8 and heel tcPO₂ < 10 mmHg (Group C). Heel blood flow was monitored using tcPO₂ sensors. Data were collected with the heel (1) suspended above the bed surface (preload), (2) on the bed surface for 30 min (loading), and (3) again suspended above the bed surface for 60 min (off-loading). Heel blood flow during off-loading was assessed using three parameters: oxygen recovery index (ORI), total tcPO₂ for the first 10 min, and change in tcPO₂ after 60 min of off-loading. ORI in Group C (n = 8) was significantly shorter than in Groups A (n = 22) and B (n = 15). Total tcPO₂ for the first 10 min of off-loading in Group C was significantly less than that in Groups A and B. Change in tcPO₂ after 60 min of off-loading in Group C was less than in Group A. Based on these findings, additional preventive care against heel blood flow decrease in older adults with an ABI < 0.8 and heel tcPO₂ < 10 mmHg might be necessary after loading.

  3. Excitation wavelength dependent photoluminescence emission behavior, UV induced photoluminescence enhancement and optical gap tuning of Zn0.45Cd0.55S nanoparticles for optoelectronic applications

    Science.gov (United States)

    Osman, M. A.; Abd-Elrahim, A. G.

    2018-03-01

    In the present study, we investigate the excitation wavelength (λex) dependent photoluminescence (PL) behavior in Zn0.45Cd0.55S nanoparticles. The deconvoluted PL emission bands for nanopowders and nanocolloids reveal noticeable spectral blue shift with decreasing λex accompanied by intensity enhancement. This unusual behavior is explained in terms of selective particle size distribution in nanostructures, advancing of fast ionization process at short λex; and solvation process in polar solvent. In addition, we attributed the UV-induced PL intensity enhancement and blue shift of the optical gap to the reduction in particle size by photo-corrosion process associated with the improvement in the quantum size effect; surface modification due to cross-linkage improvement of capping molecules at NPs surface; the creation of new radiative centers and the formation of photo-passivation layers from ZnSO4 and CdSO4, and photo-enhanced oxygen adsorption on Zn0.45Cd0.55S nanoparticles surface.

  4. Dicty_cDB: SHE226 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available n 3'HPRT insertion targeting and chromosome engineering clone MHPP186g09. 50 0.05...5 1 CR023465 |CR023465.1 Forward strand read from insert in 3'HPRT insertion targeting and chromosome engineering...targeting and chromosome engineering clone MHPP47e19. 50 0.055 1 CR034434 |CR0344...34.1 Forward strand read from insert in 3'HPRT insertion targeting and chromosome engineering clone MHPP47e1...9. 50 0.055 1 CR103667 |CR103667.1 Forward strand read from insert in 3'HPRT insertion targeting and chromosome engineering

  5. Full Scale Test SSP 34m blade, edgewise loading LTT. Extreme load and PoC_InvE Data report

    DEFF Research Database (Denmark)

    Nielsen, Magda; Roczek-Sieradzan, Agnieszka; Jensen, Find Mølholt

    This report is the second report covering the research and demonstration project “Eksperimentel vingeforskning: Strukturelle mekanismer i nutidens og fremtidens store vinger under kombineret last”, supported by the EUDP program. A 34m wind turbine blade from SSP-Technology A/S has been tested...... in edgewise direction (LTT). The blade has been submitted to thorough examination by means of strain gauges, displacement transducers and a 3D optical measuring system. This data report presents results obtained during full scale testing of the blade up to 80% Risø load, where 80% Risø load corresponds to 100...... stresses in the adhesive joints. Test results from measurements with the reinforcement have been compared to results without the coupling. The report presents only the relevant results for the 80% Risø load and the results applicable for the investigation of the influence of the invention on the profile...

  6. 40 CFR 63.650 - Gasoline loading rack provisions.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Gasoline loading rack provisions. 63... loading rack provisions. (a) Except as provided in paragraphs (b) through (c) of this section, each owner or operator of a Group 1 gasoline loading rack classified under Standard Industrial Classification...

  7. Sample loading for C-14 measurement in the simulated organic solvent waste from a CANDU Nuclear Power Plant

    International Nuclear Information System (INIS)

    Dianu, Magdalena; Podina, C.; Nita, Valentina

    2005-01-01

    Full text: Sample preparation is a critical step in obtaining accurate results in scintillation counting. Standard (22 ml) glass and plastic vials were used in these experiments. The preliminary research was conducted using glass vials to allow visual verification that a homogeneous solution is obtained at the desired cocktail/sample ratio. Then, the research was moved into plastic vials to reduce backgrounds and improve the counting rate. Samples were counted in a Model 2100 TR Packard TRI-CARB liquid scintillation analyzer. The paper mainly contains: - Composition and data about liquid scintillation cocktails used (tables); - Characterization of radioactive waste - organic solvent contaminated with C-14; - Sample loading (tables); - Efficiency vs Sample Loading - for each cocktail used. Organic solvent sample volumes were added to the vials in 0.5 ml increments from 1 ml to 2 ml. Then, the liquid scintillation cocktail was added so that the sample-cocktail volume was 20 ml. Each vial was shaken vigorously for several seconds after each addition to ensure homogeneity and count. Blank vials were prepared using C-14-free organic solvent samples in the same sample-cocktail proportions. After at least two hours, the samples and blank vials were counted for ten minutes, using a Packard counter. (authors)

  8. Magnetic bead/capture DNA/glucose-loaded nanoliposomes for amplifying the glucometer signal in the rapid screening of hepatitis C virus RNA.

    Science.gov (United States)

    Tu, Haijian; Lin, Kun; Lun, Yongzhi; Yu, Liuming

    2018-06-01

    A digital detection strategy based on a portable personal glucometer (PGM) was developed for the simple, rapid, and sensitive detection of hepatitis C virus (HCV) RNA, involving the release of glucose-loaded nanoliposomes due to coupling-site-specific cleavage by the endonuclease BamHI. The glucose-loaded nanoliposomes were synthesized using a reversed-phase evaporation method and provided an amplified signal at the PGM in the presence of HCV RNA. Initially, a 21-mer oligonucleotide complementary to HCV RNA was covalently conjugated to a magnetic bead through the amino group at the 5' end of the oligonucleotide, and then bound to a glucose-loaded liposome by typical carbodiimide coupling at its 3' end. In the presence of the target HCV RNA, the target hybridized with the oligonucleotide to form double-stranded DNA. The symmetrical duplex sequence 5'-GGATCC-3' between guanines was then catalytically cleaved by BamHI, which detached the glucose-loaded liposome from the magnetic bead. Following magnetic separation of the bead, the detached glucose-loaded liposome was lysed using Triton X-100 to release the glucose molecules within it, which were then detected as an amplified signal at the digital PGM. Under optimal conditions, the PGM signal increased with increasing HCV RNA, and displayed a strongly linear dependence on the level of HCV RNA for concentrations ranging from 10 pM to 1.0 μM. The detection limit (LOD) of the system was 1.9 pM. Good reproducibility and favorable specificity were achieved in the analysis of the target HCV RNA. Human serum samples containing HCV RNA were analyzed using this strategy, and the developed sensing platform was observed to yield satisfactory results based on a comparison with the corresponding results from a Cobas ® Amplicor HCV Test Analyzer. Graphical abstract A digital detection strategy utilizing a personal glucometer was developed for the detection of hepatitis C virus RNA. The strategy involved the use of the

  9. Sample loading for C-14 measurement in the simulated organic solvent waste from a CANDU Nuclear Power Plant

    International Nuclear Information System (INIS)

    Dianu, Magdalena; Dobrin, Relu; Podina, Corneliu

    2005-01-01

    The paper evaluates the performance of two commercially available liquid scintillation cocktails designed for counting nonaqueous (organic) samples. To choose a suitable scintillation cocktail is not always easy because many cocktails are available on the market. The efficiency, sample loading, sample type are all important variables that help determine the suitability of a liquid scintillation cocktail for C-14 measurement. Samples were counted in a 2100 TRI-CARB Packard Model liquid scintillation analyzer. (authors)

  10. Using bench press load to predict upper body exercise loads in physically active individuals.

    Science.gov (United States)

    Wong, Del P; Ngo, Kwan-Lung; Tse, Michael A; Smith, Andrew W

    2013-01-01

    This study investigated whether loads for assistance exercises of the upper body can be predicted from the loads of the bench press exercise. Twenty-nine physically active collegiate students (age: 22.6 ± 2.5; weight training experience: 2.9 ± 2.1 years; estimated 1RM bench press: 54.31 ± 14.60 kg; 1RM: body weight ratio: 0.80 ± 0.22; BMI: 22.7 ± 2.1 kg·m(-2)) were recruited. The 6RM loads for bench press, barbell bicep curl, overhead dumbbell triceps extension, hammer curl and dumbbell shoulder press were measured. Test-retest reliability for the 5 exercises as determined by Pearson product moment correlation coefficient was very high to nearly perfect (0.82-0.98, p bench press load was significantly correlated with the loads of the 4 assistance exercises (r ranged from 0.80 to 0.93, p bench press load was a significant (R(2) range from 0.64 to 0.86, p Bench press load (0.28) + 6.30 kg, (b) Barbell biceps curl = Bench press load (0.33) + 6.20 kg, (c) Overhead triceps extension = Bench press load (0.33) - 0.60 kg, and (d) Dumbbell shoulder press = Bench press load (0.42) + 5.84 kg. The difference between the actual load and the predicted load using the four equations ranged between 6.52% and 8.54%, such difference was not significant. Fitness professionals can use the 6RM bench press load as a time effective and accurate method to predict training loads for upper body assistance exercises. Key pointsThe bench press load was significantly correlated with the loads of the 4 assistance exercises.No significant differences were found between the actual load and the predicted load in the four equations.6RM bench press load can be a time effective and accurate method to predict training loads for upper body assistance exercises.

  11. Determination of in vivo behavior of mitomycin C-loaded o/w soybean oil microemulsion and mitomycin C solution via gamma camera imaging.

    Science.gov (United States)

    Kotmakçı, Mustafa; Kantarcı, Gülten; Aşıkoğlu, Makbule; Ozkılıç, Hayal; Ertan, Gökhan

    2013-09-01

    In this study, a microemulsion system was evaluated for delivery of mitomycin C (MMC). To track the distribution of the formulated drug after intravenous administration, radiochemical labeling and gamma scintigraphy imaging were used. The aim was to evaluate a microemulsion system for intravenous delivery of MMC and to compare its in vivo behavior with that of the MMC solution. For microemulsion formulation, soybean oil was used as the oil phase. Lecithin and Tween 80 were surfactants and ethanol was the cosurfactant. To understand the whole body localization of MMC-loaded microemulsion, MMC was labeled with radioactive technetium and gamma scintigraphy was applied for visualization of drug distribution. Radioactivity in the bladder 30 minutes after injection of the MMC solution was observed, according to static gamma camera images. This shows that urinary excretion of the latter starts very soon. On the other hand, no radioactivity appeared in the urinary bladder during the 90 minutes following the administration of MMC-loaded microemulsion. The unabated radioactivity in the liver during the experiment shows that the localization of microemulsion formulation in the liver is stable. In the light of the foregoing, it is suggested that this microemulsion formulation may be an appropriate carrier system for anticancer agents by intravenous delivery in hepatic cancer chemotherapy.

  12. Bufalin-loaded mPEG-PLGA-PLL-cRGD nanoparticles: preparation, cellular uptake, tissue distribution, and anticancer activity

    Directory of Open Access Journals (Sweden)

    Duan YR

    2012-07-01

    Full Text Available Peihao Yin,1,* Yan Wang,1,* YanYan Qiu,1 LiLi Hou,1 Xuan Liu,1 Jianmin Qin,1 Yourong Duan,2 Peifeng Liu,2 Ming Qiu,3 Qi Li11Department of Clinical Oncology, Putuo Hospital and Interventional Cancer Institute of Integrative Medicine, Shanghai University of Traditional Chinese Medicine, Shanghai, China; 2Shanghai Cancer Institute, Jiaotong University, Shanghai, China; 3Department of General Surgery, Changzheng Hospital, Second Military Medical University, Shanghai, China *These authors contributed equally to this workBackground: Recent studies have shown that bufalin has a good antitumor effect but has high toxicity, poor water solubility, a short half-life, a narrow therapeutic window, and a toxic dose that is close to the therapeutic dose, which all limit its clinical application. This study aimed to determine the targeting efficacy of nanoparticles (NPs made of methoxy polyethylene glycol (mPEG, polylactic-co-glycolic acid (PLGA, poly-L-lysine (PLL, and cyclic arginine-glycine-aspartic acid (cRGD loaded with bufalin, ie, bufalin-loaded mPEG-PLGA-PLL-cRGD nanoparticles (BNPs, in SW620 colon cancer-bearing mice.Methods: BNPs showed uniform size. The size, shape, zeta potential, drug loading, encapsulation efficiency, and release of these nanoparticles were studied in vitro. The tumor targeting, cellular uptake, and growth-inhibitory effect of BNPs in vivo were tested.Results: BNPs were of uniform size with an average particle size of 164 ± 84 nm and zeta potential of 2.77 mV. The encapsulation efficiency was 81.7% ± 0.89%, and the drug load was 3.92% ± 0.16%. The results of in vitro cytotoxicity studies showed that although the blank NPs were nontoxic, they enhanced the cytotoxicity of bufalin in BNPs. Drug release experiments showed that the release of the drug was prolonged and sustained. The results of confocal laser scanning microscopy indicated that BNPs could effectively bind to human umbilical vein endothelial cells. In the SW620

  13. Mechanical behavior of Fe{sub 75}Mo{sub 5}P{sub 10}C{sub 7.5}B{sub 2.5} bulk-metallic glass under torsional loading

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Xinjian [School of Chemical Engineering and Technology, Tianjin University, 92 Weijin Road, Tianjin 300072 (China); Huang Lu [Department of Materials Science and Engineering, University of Tennessee, TN 37996 (United States); Key Laboratory of Aerospace Materials and Performance (Ministry of Education), School of Materials Science and Engineering, Beijing University of Aeronautics and Astronautics, Beijing 100191 (China); Chen Xu, E-mail: xchen@tju.edu.cn [School of Chemical Engineering and Technology, Tianjin University, 92 Weijin Road, Tianjin 300072 (China); Liaw, Peter K. [Department of Materials Science and Engineering, University of Tennessee, TN 37996 (United States); An Ke [Neutron Scattering Sciences Division, Oak Ridge National Laboratory, TN 37831 (United States); Zhang Tao [Key Laboratory of Aerospace Materials and Performance (Ministry of Education), School of Materials Science and Engineering, Beijing University of Aeronautics and Astronautics, Beijing 100191 (China); Wang Gongyao [Department of Materials Science and Engineering, University of Tennessee, TN 37996 (United States)

    2010-11-15

    Research highlights: {yields} Fe{sub 75}Mo{sub 5}P{sub 10}C{sub 7.5}B{sub 2.5} bulk-metallic glass exhibits a brittle characteristic under torsional loading. {yields} The BMG occurs in a tensile mode failure under torsional loading. {yields} A slight cyclic-hardening behavior was observed in the initial loading cycles during torsional-fatigue tests. {yields} The torsional fatigue-fracture surface consists of three main regions. - Abstract: Pure- and cyclic-torsional studies were conducted on a Fe{sub 75}Mo{sub 5}P{sub 10}C{sub 7.5}B{sub 2.5} (atomic percent, at.%) bulk-metallic glass at room temperature for an understanding of its damage and fracture mechanisms. Under pure-torsional loading, the metallic glass exhibited very little plastic strain before fracture. The fracture initiated along the maximum tensile-stress plane, which is about 45{sup o} to the axial direction. The shear-fracture strength ({approx}510 MPa) is much lower than the compressive-fracture strength ({approx}3280 MPa), which suggests that different deformation mechanisms be present under various loading modes. Instead of an apparent vein-type structure, the fracture morphologies revealed a crack-initiation site, a mirror region, a mist region, and a hackle region. Under cyclic-torsional loading, fatigue cracks initiated from casting defects, and propagate generally along the maximum tensile-stress plane. A slight cyclic-hardening behavior was observed in initial loading steps. The fatigue-fracture surface consists of three main regions: the fatigue crack-initiation, crack-propagation, and final-fast-fracture areas. The striations resulting from the blunting and re-sharpening of the fatigue crack tip were observed in the crack-propagation region. Based on these results, the damage and fracture mechanisms of the metallic glass induced by torsional loadings are elucidated.

  14. 30 CFR 75.1318 - Loading boreholes.

    Science.gov (United States)

    2010-07-01

    ... protect persons shall be done in the working place or other area where blasting is to be performed. (c) When loading boreholes drilled at an angle of 45 degrees or greater from the horizontal in solid rock... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Explosives and Blasting § 75.1318 Loading boreholes. (a...

  15. Perceptual Load Affects Eyewitness Accuracy & Susceptibility to Leading Questions

    OpenAIRE

    Gillian Murphy; Ciara Mary Greene

    2016-01-01

    Load Theory (Lavie, 1995; 2005) states that the level of perceptual load in a task (i.e. the amount of information involved in processing task-relevant stimuli) determines the efficiency of selective attention. There is evidence that perceptual load affects distractor processing, with increased inattentional blindness under high load. Given that high load can result in individuals failing to report seeing obvious objects, it is conceivable that load may also impair memory for the scene. The c...

  16. Analysis of a postulated pipe rupture and subsequent check valve slam of a PWR feedwater line

    International Nuclear Information System (INIS)

    Chang, K.C.; Adams, T.M.

    1983-01-01

    System designs criteria employed in the design of pressurized water reactors (PWR) requires that, for a postulated instantaneous guillotine rupture anywhere in the steam generator feedwater system, no more than one steam generator can be allowed to blowdown. Feedwater systems in many PWR's consist of pipe lines running from the feedwater pumps into a common feedwater header then branching into each steam generator from the header. The feedwater piping to each steam generator contains swing check valves to prevent reverse flow from the steam generator. This activation of some or all of these check valves significantly complicates the system structural analysis in that not only the blowdown forces resulting from the postulated pipe rupture, but also the water hammer loads resulting from closure of the check valve at high reverse flow velocities must be considered. The loads resulting from system blowdown and check valve closure are axial in nature. Peak loads ranging from 130000 lbs. to 180000 lbs. are not uncommon and are layout dependent. The analysis and design to withstand this transient loading deviates from the usual feedwater line design in that supports are required along the piping axis in the direction normal to the usual seismic supports. A brief and general discussion of the methods employed in the generation of the thermal-hydraulic loadings is presented. However, the discussion emphasizes the piping and piping support structural design and analysis method and approaches used in evaluating a selected portion of such a feedwater system. (orig./RW)

  17. Load cell adoption in an electronic drag force flowmeter Medidor de vazão eletrônico com célula de carga

    Directory of Open Access Journals (Sweden)

    Antonio Pires de Camargo

    2011-06-01

    Full Text Available This research introduces the development of an electronic flowmeter based on the drag force that a body experiences when immersed in a fluid stream. Its main goal was the development of an Electronic Drag Force Flowmeter (EDFF using a load cell, as well as the evaluation of its performance parameters. The developed flowmeter should not require specialized labor, equipments, computers or any sophisticated and complex method, providing an easy and accurate way of flow estimation. This research was carried out in the following stages: (i EDFF mechanical structure development; (ii data acquisition system and embedded software design; and (iii evaluation of EDFF performance parameters. EDFF has routines for instantaneous flow rate measurement, interactive calibration, and also several flow meter parameter adjustments, allowing data transmission via a RS232 protocol. The real-time flow measurement task updates values of instantaneous flow rate each seven seconds, enabling unit selection. The interactive calibration routine guides users during all calibration process showing instructions on EDFF's display. A data digital filtering procedure was implemented in an embedded software using the Grubbs' Test in order to identify and to remove outliers from the acquired data. The Method of Least Squares was also implemented in the embedded software in order to calculate the fitting model coefficients on the calibration procedure. This flowmeter is able to work from 1.94 to 7.78 dm³ s-1 with an uncertainty of ± 5.7%. The coefficient of local head loss (K was close to 0.55 for Reynolds number values higher than 10(5. The developed EDFF is a low-cost and stand-alone system with potential for agricultural applications.Este estudo apresenta o desenvolvimento de um medidor de vazão baseado na força de arraste que atua em um corpo imerso em uma corrente líquida. O principal objetivo foi o desenvolvimento de um Medidor de Vazão Eletrônico tipo Força (MVEF

  18. New Observations of Soft X-ray (0.5-5 keV) Solar Spectra

    Science.gov (United States)

    Caspi, A.; Woods, T. N.; Mason, J. P.; Jones, A. R.; Warren, H. P.

    2013-12-01

    The solar corona is the brightest source of X-rays in the solar system, and the X-ray emission is highly variable on many time scales. However, the actual solar soft X-ray (SXR) (0.5-5 keV) spectrum is not well known, particularly during solar quiet periods, as, with few exceptions, this energy range has not been systematically studied in many years. Previous observations include high-resolution but very narrow-band spectra from crystal spectrometers (e.g., Yohkoh/BCS), or integrated broadband irradiances from photometers (e.g., GOES/XRS, TIMED/XPS, etc.) that lack detailed spectral information. In recent years, broadband measurements with moderate energy resolution (~0.5-0.7 keV FWHM) were made by SphinX on CORONAS-Photon and SAX on MESSENGER, although they did not extend to energies below ~1 keV. We present observations of solar SXR emission obtained using new instrumentation flown on recent SDO/EVE calibration rocket underflights. The photon-counting spectrometer, a commercial Amptek X123 with a silicon drift detector and an 8 μm Be window, measures the solar disk-integrated SXR emission from ~0.5 to >10 keV with ~0.15 keV FWHM resolution and 1 s cadence. A novel imager, a pinhole X-ray camera using a cooled frame-transfer CCD (15 μm pixel pitch), Ti/Al/C filter, and 5000 line/mm Au transmission grating, images the full Sun in multiple spectral orders from ~0.1 to ~5 nm with ~10 arcsec/pixel and ~0.01 nm/pixel spatial and spectral detector scales, respectively, and 10 s cadence. These instruments are prototypes for future CubeSat missions currently being developed. We present new results of solar observations on 04 October 2013 (NASA sounding rocket 36.290). We compare with previous results from 23 June 2012 (NASA sounding rocket 36.286), during which solar activity was low and no signal was observed above ~4 keV. We compare our spectral and imaging measurements with spectra and broadband irradiances from other instruments, including SDO/EVE, GOES/XRS, TIMED

  19. Loads and loads and loads: the influence of prospective load, retrospective load, and ongoing task load in prospective memory

    Science.gov (United States)

    Meier, Beat; Zimmermann, Thomas D.

    2015-01-01

    In prospective memory tasks different kinds of load can occur. Adding a prospective memory task can impose a load on ongoing task performance. Adding ongoing task load (OTL) can affect prospective memory performance. The existence of multiple target events increases prospective load (PL) and adding complexity to the to-be-remembered action increases retrospective load (RL). In two experiments, we systematically examined the effects of these different types of load on prospective memory performance. Results showed an effect of PL on costs in the ongoing task for categorical targets (Experiment 2), but not for specific targets (Experiment 1). RL and OTL both affected remembering the retrospective component of the prospective memory task. We suggest that PL can enhance costs in the ongoing task due to additional monitoring requirements. RL and OTL seem to impact the division of resources between the ongoing task and retrieval of the retrospective component, which may affect disengagement from the ongoing task. In general, the results demonstrate that the different types of load affect prospective memory differentially. PMID:26082709

  20. Loads and loads and loads: the influence of prospective load, retrospective load, and ongoing task load in prospective memory.

    Science.gov (United States)

    Meier, Beat; Zimmermann, Thomas D

    2015-01-01

    In prospective memory tasks different kinds of load can occur. Adding a prospective memory task can impose a load on ongoing task performance. Adding ongoing task load (OTL) can affect prospective memory performance. The existence of multiple target events increases prospective load (PL) and adding complexity to the to-be-remembered action increases retrospective load (RL). In two experiments, we systematically examined the effects of these different types of load on prospective memory performance. Results showed an effect of PL on costs in the ongoing task for categorical targets (Experiment 2), but not for specific targets (Experiment 1). RL and OTL both affected remembering the retrospective component of the prospective memory task. We suggest that PL can enhance costs in the ongoing task due to additional monitoring requirements. RL and OTL seem to impact the division of resources between the ongoing task and retrieval of the retrospective component, which may affect disengagement from the ongoing task. In general, the results demonstrate that the different types of load affect prospective memory differentially.

  1. Dicty_cDB: Contig-U12726-1 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available ( DU826786 ) FLAS_CR30-2002_05F11.T7M FLAS_CR30-2002 unculture... 46 0.41 1 ( AL404104 ) T3 end of clone AT0AA013B12 of library...mid clone: MOF-010N15, gen... 46 0.41 1 ( CT559968 ) A BAC library has been constructed from cultivar ... 46...1 ( BG450438 ) NF015E06DT1F1051 Drought Medicago truncatula cDNA... 50 0.027 1 ( BF649099 ) NF055E07EC1F1053 Elicited cell culture... Medicago t... 50 0.027 1 ( BF644378 ) NF061A10EC1F1072 Elicited cell culture Medicago...M0435G20F Mouse 10kb plasmid UUGC1M library Mus ... 48 0.10 1 ( AL405948 ) T7 end of clone AU0AA007C03 of library

  2. Gas load forecasting based on optimized fuzzy c-mean clustering analysis of selecting similar days

    Directory of Open Access Journals (Sweden)

    Qiu Jing

    2017-08-01

    Full Text Available Traditional fuzzy c-means (FCM clustering in short term load forecasting method is easy to fall into local optimum and is sensitive to the initial cluster center.In this paper,we propose to use global search feature of particle swarm optimization (PSO algorithm to avoid these shortcomings,and to use FCM optimization to select similar date of forecast as training sample of support vector machines.This will not only strengthen the data rule of training samples,but also ensure the consistency of data characteristics.Experimental results show that the prediction accuracy of this prediction model is better than that of BP neural network and support vector machine (SVM algorithms.

  3. Status of load management

    Energy Technology Data Exchange (ETDEWEB)

    Juchymenko, A

    1983-08-01

    A summary is presented of the status of load management, defined as any activity by an electric utility to affect the size and characteristics of its load. Load management is currently viewed by electric utilities as an important tool for marketing electricity in a competitive fuel situation. A major aim of the National Energy Program is to reduce Canada's dependence on oil by 1990 to 10% of the energy used by all markets. As a result, electricity may play a greater role in the supply of primary energy. Research in load management has been directed mostly towards the residential market, especially direct control of domestic hot water heaters and air conditioners. Studies conducted in Canada and the U.S. to determine user's receptiveness to direct control of loads and thermal energy storage systems indicate that these load management techniques are in most cases not acceptable to customers, who prefer voluntary reduction in demand. The potential exists in the industrial market to use load management to assist in electrifying many of the fossil fuel-fired processes at competitive energy prices. Some of the more important applications include an industrial heat pump to heat liquids to 120{degree}C, induction heating for melting and heat treating of metals, and mechanical vapor recompression equipment to produce proces steam. 21 refs., 2 figs., 2 tabs.

  4. Electrochemical properties of the MmNi3.55Mn0.4Al0.3Co0.75-xFex (x = 0.55 and 0.75) compounds

    International Nuclear Information System (INIS)

    Ben Moussa, M.; Abdellaoui, M.; Mathlouthi, H.; Lamloumi, J.; Guegan, A. Percheron

    2008-01-01

    The hydrogen storage alloys MmNi 3.55 Mn 0.4 Al 0.3 Co 0.75-x Fe x (x = 0.55 and 0.75) were used as negative electrodes in the Ni-MH accumulators. The chronopotentiommetry and the cyclic voltammetry were applied to characterize the electrochemical properties of these alloys. The obtained results showed that the substitution of the cobalt atoms by iron atoms has a good effect on the life cycle of the electrode. For the MmNi 3.55 Mn 0.4 Al 0.3 Co 0.2 Fe 0.55 compound, the discharge capacity reaches its maximum of 210 mAh/g after 12 cycles and then decreases to 190 mAh/g after 30 charge-discharge cycles. However, for the MmNi 3.55 Mn 0.4 Al 0.3 Fe 0.75 compound, the discharge capacity reaches its maximum of 200 mAh/g after 10 cycles and then decreases to 160 mAh/g after 30 cycles. The diffusion behavior of hydrogen in the negative electrodes made from these alloys was characterized by cyclic voltammetry after few activation cycles. The values of the hydrogen coefficient in MmNi 3.55 Mn 0.4 Al 0.3 Co 0.2 Fe 0.55 and MmNi 3.55 Mn 0.4 Al 0.3 Fe 0.75 are, respectively, equal to 2.96 x 10 -9 and 4.98 x 10 -10 cm 2 s -1 . However, the values of the charge transfer coefficients are, respectively, equal to 0.33 and 0.3. These results showed that the substitution of cobalt by iron decreases the reversibility and the kinetic of the electrochemical reaction in these alloys

  5. Relevance of plastic limit loads to reference stress approach for surface cracked cylinder problems

    International Nuclear Information System (INIS)

    Kim, Yun-Jae; Shim, Do-Jun

    2005-01-01

    To investigate the relevance of the definition of the reference stress to estimate J and C* for surface crack problems, this paper compares finite element (FE) J and C* results for surface cracked pipes with those estimated according to the reference stress approach using various definitions of the reference stress. Pipes with part circumferential inner surface cracks and finite internal axial cracks are considered, subject to internal pressure and global bending. The crack depth and aspect ratio are systematically varied. The reference stress is defined in four different ways using (i) a local limit load (ii), a global limit load, (iii) a global limit load determined from the FE limit analysis, and (iv) the optimised reference load. It is found that the reference stress based on a local limit load gives overall excessively conservative estimates of J and C*. Use of a global limit load clearly reduces the conservatism, compared to that of a local limit load, although it can sometimes provide non-conservative estimates of J and C*. The use of the FE global limit load gives overall non-conservative estimates of J and C*. The reference stress based on the optimised reference load gives overall accurate estimates of J and C*, compared to other definitions of the reference stress. Based on the present findings, general guidance on the choice of the reference stress for surface crack problems is given

  6. LBS Management Review: Submissions

    African Journals Online (AJOL)

    Author Guidelines. The Lagos Business School Management Review is published by management professionals for practising managers, without sacrificing academic standards. The Review welcomes articles that enhance knowledge about the process of managing an organisation as well as reflect techniques, trends and ...

  7. Connection of thermopower and giant magnetothermopower with magnetic and structural heterogeneity in Sm{sub 0.55}Sr{sub 0.45}MnO{sub 3} manganite

    Energy Technology Data Exchange (ETDEWEB)

    Koroleva, L.I., E-mail: lyudkorolyova@yandex.ru [Moscow State University, Leninskie Gory 1, 119991 Moscow (Russian Federation); Morozov, A.S.; Jakhina, E.S. [Moscow State University, Leninskie Gory 1, 119991 Moscow (Russian Federation); Balbashov, A.M. [Moscow Power Institute, Krasnokazarmennaya street,14, 111250 Moscow (Russian Federation)

    2015-12-15

    It was first shown that the thermoelectric power in a magnetic semiconductor Sm{sub 0.55}Sr{sub 0.45}MnO{sub 3} is caused by ferromagnetic (FM) ferron-type nanoclusters and antiferromagnetic (AFM) CE-type nanoclusters with charge-orbital (CO) ordering. The presence of these clusters is caused by heavily Sr doping of a SmMnO{sub 3} compound, which replaced Sm ions. Thermoelectric power S and magnetothermopower ΔS/S has been studied in three samples: ceramics and two single-crystal samples. One of single-crystals was cooled in the air, another one was cooled in an oxygen atmosphere. The annealing in oxygen closes oxygen vacancies and, thus, increases the fraction of the CE-type AFM phase with the CO ordering which displaces the oxygen ions. S(T) curves of single-crystal sample cooled in the air and ceramic sample have a sharp increase starting from Curie temperature (T{sub C}) region and a slow decline till 325 K. At the same time {ΔS/S}(T) curves have a sharp minimum near T{sub C}=126 K, reaching the giant absolute value of 87% in the magnetic field H=14.17 kOe. This means that thermopower almost vanish with thermal destruction of FM clusters, i.e. thermopower is caused by these clusters in which crystal lattice is compressed. Oxygen cooled single-crystal's S(T) curves have a broad maximum near 270 K, including Neel temperature of CE-type clusters T{sub NCE}=240 K. {ΔS/S}(T) curve has a sharp minimum at the T{sub NCE} reaching the absolute value of 50% in H=13.2 kOe. The decrease of S is caused by destruction of CO order displacing oxygen ions in CE-type AFM clusters. Thus changed crystal lattice in nanoclusters of ferron type or AFM of CE-type makes the main contribution in thermopower in these three samples. - Highlights: • Thermopower S and magnetothermopower ΔS/S has been studied in Sm{sub 0.55}Sr{sub 0.45}MnO{sub 3}. • Sample consists of ferromagnetic and antiferromagnetic (AF) CE-type clusters. • Maxima of S and |ΔS/S| were observed at Curie

  8. Crack assessment of pipe under combined thermal and mechanical load

    International Nuclear Information System (INIS)

    Song, Tae Kwang; Kim, Yun Jae

    2009-01-01

    In this paper, J-integral and transient C(t)-integral, which were key parameters in low temperature and high temperature fracture mechanics, under combined thermal and mechanical load were estimated via 3-dimensional finite element analyses. Various type of thermal and mechanical load, material hardening were considered to decrease conservatism in existing solutions. As a results, V-factor and redistribution time for combined thermal and mechanical load were proposed to calculate J-integral and C(t)-integral, respectively.

  9. Analysis and Test Correlation of Proof of Concept Box for Blended Wing Body-Low Speed Vehicle

    Science.gov (United States)

    Spellman, Regina L.

    2003-01-01

    The Low Speed Vehicle (LSV) is a 14.2% scale remotely piloted vehicle of the revolutionary Blended Wing Body concept. The design of the LSV includes an all composite airframe. Due to internal manufacturing capability restrictions, room temperature layups were necessary. An extensive materials testing and manufacturing process development effort was underwent to establish a process that would achieve the high modulus/low weight properties required to meet the design requirements. The analysis process involved a loads development effort that incorporated aero loads to determine internal forces that could be applied to a traditional FEM of the vehicle and to conduct detailed component analyses. A new tool, Hypersizer, was added to the design process to address various composite failure modes and to optimize the skin panel thickness of the upper and lower skins for the vehicle. The analysis required an iterative approach as material properties were continually changing. As a part of the material characterization effort, test articles, including a proof of concept wing box and a full-scale wing, were fabricated. The proof of concept box was fabricated based on very preliminary material studies and tested in bending, torsion, and shear. The box was then tested to failure under shear. The proof of concept box was also analyzed using Nastran and Hypersizer. The results of both analyses were scaled to determine the predicted failure load. The test results were compared to both the Nastran and Hypersizer analytical predictions. The actual failure occurred at 899 lbs. The failure was predicted at 1167 lbs based on the Nastran analysis. The Hypersizer analysis predicted a lower failure load of 960 lbs. The Nastran analysis alone was not sufficient to predict the failure load because it does not identify local composite failure modes. This analysis has traditionally been done using closed form solutions. Although Hypersizer is typically used as an optimizer for the design

  10. Analysis and Tests of Reinforced Carbon-Epoxy/Foam-Core Sandwich Panels with Cutouts

    Science.gov (United States)

    Baker, Donald J.; Rogers, Charles

    1996-01-01

    The results of a study of a low-cost structurally efficient minimum-gage shear-panel design that can be used in light helicopters are presented. The shear-panel design is based on an integrally stiffened syntactic-foam stabilized-skin with an all-bias-ply tape construction for stabilized-skin concept with an all-bias-ply tape construction for the skins. This sandwich concept is an economical way to increase the panel bending stiffness weight penalty. The panels considered in the study were designed to be buckling resistant up to 100 lbs/in. of shear load and to have an ultimate strength of 300 lbs/in. The panel concept uses unidirectional carbon-epoxy tape on a syntactic adhesive as a stiffener that is co-cured with the skin and is an effective concept for improving panel buckling strength. The panel concept also uses pultruded carbon-epoxy rods embedded in a syntactic adhesive and over-wrapped with a bias-ply carbon-epoxy tape to form a reinforcing beam which is an effective method for redistributing load around rectangular cutout. The buckling strength of the reinforced panels is 83 to 90 percent of the predicted buckling strength based on a linear buckling analysis. The maximum experimental deflection exceeds the maximum deflection predicted by a nonlinear analysis by approximately one panel thickness. The failure strength of the reinforced panels was two and a half to seven times of the buckling strength. This efficient shear-panel design concept exceeds the required ultimate strength requirement of 300 lbs/in by more than 100 percent.

  11. Mechanical properties and microstructure of austenitic steels loaded with helium using tritium

    International Nuclear Information System (INIS)

    Sacovy, Paulette; Brun, Gilbert; Delaplace, Jean; Devaux, Joel; Fidelle, J.P.

    1982-06-01

    Following a review of the principle of the method using the radioactive decay of tritium to helium 3 to introduce helium into thick metallic test specimens, the results of preliminary tests performed on austenitic steels are presented. 304L and 316 steel specimens were loaded with helium, treated at 760 0 C to precipitate the helium in bubbles, and then strained by tensile stress at 800 0 C. In the material most loaded with helium (304 steel containing 230 ppm at. helium), a significant increase in distributed and total elongation at 800 0 C was observed. In the least loaded material (steel 316 containing 13 ppm at. helium), only total elongation decreased. Neither the yield stress nor the breaking load was altered by the presence of helium. Observations made by electron microscopy in the most loaded material revealed the presence, after heat treatment at 760 0 C, of very small bubbles of helium and also imperfect dislocation loops. The cause of these fault loops is discussed [fr

  12. Preparation and Optimization OF Palm-Based Lipid Nanoparticles Loaded with Griseofulvin.

    Science.gov (United States)

    Huei Lim, Wen; Jean Tan, Yann; Sin Lee, Choy; Meng Er, Hui; Fung Wong, Shew

    2017-01-01

    Palm-based lipid nanoparticle formulation loaded with griseofulvin was prepared by solvent-free hot homogenization method. The griseofulvin loaded lipid nanoparticles were prepared via stages of optimisation, by altering the high pressure homogenisation (HPH) parameters, screening on palm-based lipids and Tween series surfactants and selection of lipid to surfactant ratios. A HPLC method has been validated for the drug loading capacity study. The optimum HPH parameter was determined to be 1500 bar with 5 cycles and among the palm-based lipid materials; Lipid C (triglycerides) was selected for the preparation of lipid nanoparticles. Tween 80 was chosen from the Tween series surfactants for its highest saturated solubility of griseofulvin at 53.1 ± 2.16 µg/mL. The optimum formulation of the griseofulvin loaded lipid nanoparticles demonstrated nano-range of particle size (179.8 nm) with intermediate distribution index (PDI) of 0.306, zeta potential of -27.9 mV and drug loading of 0.77%. The formulation was stable upon storage for 1 month at room temperature (25 ° C) and 45 ° C with consistent drug loading capacity.

  13. Observation of an electron band above the Fermi level in FeTe0.55Se0.45 from in-situ surface doping

    International Nuclear Information System (INIS)

    Zhang, P.; Ma, J.; Qian, T.; Richard, P.; Ding, H.; Xu, N.; Xu, Y.-M.; Fedorov, A. V.; Denlinger, J. D.; Gu, G. D.

    2014-01-01

    We used in-situ potassium (K) evaporation to dope the surface of the iron-based superconductor FeTe 0.55 Se 0.45 . The systematic study of the bands near the Fermi level confirms that electrons are doped into the system, allowing us to tune the Fermi level of this material and to access otherwise unoccupied electronic states. In particular, we observe an electron band located above the Fermi level before doping that shares similarities with a small three-dimensional pocket observed in the cousin, heavily electron-doped KFe 2−x Se 2 compound.

  14. Modeling of creep-fatigue interaction of zirconium {alpha} under cyclic loading at 200 C; Modelisation du comportement et de l`endommagement en fatigue-fluage du zirconium {alpha} a 200C

    Energy Technology Data Exchange (ETDEWEB)

    Vogel, C.

    1996-04-01

    The present work deals with mechanical behaviour of zirconium alpha at 200 deg. C and crack initiation prediction methods, particularly when loading conditions lead to interaction of fatigue and creep phenomena. A classical approach used to study interaction between cyclic effects and constant loading effects does not give easy understanding of experimental results. Therefore, a new approach has been developed, which allow to determine a number of cycles for crack initiation for complex structures under large loading conditions. To study influence of fatigue and creep interaction on crack initiation, a model was chosen, using a scalar variable, giving representation of the material deterioration state. The model uses a non linear cumulating effect between the damage corresponding to cyclic loads and the damage correlated to time influence. The model belongs to uncoupled approaches between damage and behaviour, which is described here by a two inelastic deformations model. This mechanical behaviour model is chosen because it allows distinction between a plastic and a viscous part in inelastic flow. Cyclic damage is function of stress amplitude and mean stress. For the peculiar sensitivity of the material to creep, a special parameter bas been defined to be critical toward creep damage. It is the kinematic term associated to state variables describing this type of hardening in the viscous mechanism. (author).

  15. Acute Toxicity Study of Zerumbone-Loaded Nanostructured Lipid Carrier on BALB/c Mice Model

    Directory of Open Access Journals (Sweden)

    Heshu Sulaiman Rahman

    2014-01-01

    Full Text Available Zerumbone- (ZER- loaded nanostructure lipid carrier (NLC (ZER-NLC prepared for its antileukemia effect in vitro was evaluated for its toxicological effects by observing changes in the liver, kidney, spleen, lung, heart, and brain tissues, serum biochemical parameters, total haemogram, and bone marrow stem cells. The acute toxicity study for ZER-NLC was conducted by orally treating BALB/c mice with a single dose with either water, olive oil, ZER, NLC, or ZER-NLC for 14 days. The animals were observed for clinical and behavioral abnormalities, toxicological symptoms, feed consumption, and gross appearance. The liver, kidney, heart, lung, spleen, and brain tissues were assessed histologically. Total haemogram was counted by hemocytometry and microhematocrit reader. Bone marrow examination in terms of cellular morphology was done by Wright staining with bone marrow smear. Furthermore, serum biochemical parameters were determined spectrophotometrically. Grossly all treated mice, their investigated tissues, serum biochemical parameters, total haemogram, and bone marrow were normal. At oral doses of 100 and 200 mg/kg ZER-NLC there was no sign of toxicity or mortality in BALB/c mice. This study suggests that the 50% lethal dose (LD50 of ZER-NLC is higher than 200 mg/kg, thus, safe by oral administration.

  16. Measuring achievement goal motivation, mindsets and cognitive load: validation of three instruments' scores.

    Science.gov (United States)

    Cook, David A; Castillo, Richmond M; Gas, Becca; Artino, Anthony R

    2017-10-01

    Measurement of motivation and cognitive load has potential value in health professions education. Our objective was to evaluate the validity of scores from Dweck's Implicit Theories of Intelligence Scale (ITIS), Elliot's Achievement Goal Questionnaire-Revised (AGQ-R) and Leppink's cognitive load index (CLI). This was a validity study evaluating internal structure using reliability and factor analysis, and relationships with other variables using the multitrait-multimethod matrix. Two hundred and thirty-two secondary school students participated in a medical simulation-based training activity at an academic medical center. Pre-activity ITIS (implicit theory [mindset] domains: incremental, entity) and AGQ-R (achievement goal domains: mastery-approach, mastery-avoidance, performance-approach, performance-avoidance), post-activity CLI (cognitive load domains: intrinsic, extrinsic, germane) and task persistence (self-directed repetitions on a laparoscopic surgery task) were measured. Internal consistency reliability (Cronbach's alpha) was > 0.70 for all domain scores except AGQ-R performance-avoidance (alpha 0.68) and CLI extrinsic load (alpha 0.64). Confirmatory factor analysis of ITIS and CLI scores demonstrated acceptable model fit. Confirmatory factor analysis of AGQ-R scores demonstrated borderline fit, and exploratory factor analysis suggested a three-domain model for achievement goals (mastery-approach, performance and avoidance). Correlations among scores from conceptually-related domains generally aligned with expectations, as follows: ITIS incremental and entity, r = -0.52; AGQ-R mastery-avoidance and performance-avoidance, r = 0.71; mastery-approach and performance-approach, r = 0.55; performance-approach and performance-avoidance, r = 0.43; mastery-approach and mastery-avoidance, r = 0.36; CLI germane and extrinsic, r = -0.35; ITIS incremental and AGQ-R mastery-approach, r = 0.34; ITIS incremental and CLI germane, r = 0.44; AGQ-R mastery

  17. PPOOLEX experiments on dynamic loading with pressure feedback

    International Nuclear Information System (INIS)

    Puustinen, M.; Laine, J.; Raesaenen, A.

    2011-01-01

    This report summarizes the results of the dynamic loading experiments (DYN series) carried out with the scaled down, two compartment PPOOLEX test facility designed and constructed at LUT. Steam was blown into the dry well compartment and from there through the DN200 vertical blowdown pipe to the condensation pool filled with sub-cooled water. The main purpose of the experiments was to study dynamic loads caused by different condensation modes. Particularly, the effect of counterpressure on loads due to pressure oscillations induced by chugging was of interest. Before the experiments the condensation pool was filled with isothermal water so that the blowdown pipe outlet was submerged by 1.03-1.11 m. The initial temperature of the pool water varied from 11 deg. C to 63 deg. C, the steam flow rate from 290 g/s to 1220 g/s and the temperature of incoming steam from 132 deg. C to 182 deg. C. Non-condensables were pushed from the dry well into the gas space of the wet well with a short discharge of steam before the recorded period of the experiments. As a result of this procedure, the system pressure was at an elevated level in the beginning of the actual experiments. An increased counterpressure was used in the last experiment of the series. The diminishing effect of increased system pressure on chugging intensity and on measured loads is evident from the results of the last experiment. The highest pressure pulses both inside the blowdown pipe and in the condensation pool were about half of those measured with a lower system pressure but otherwise with similar test parameters. The experiments on dynamic loading gave expected results. The loads experienced by pool structures depended strongly on the steam mass flow rate, pool water temperature and system pressure. The DYN experiments indicated that chugging and condensation within the blowdown pipe cause significant dynamic loads in case of strongly sub-cooled pool water. The level of pool water temperature is decisive

  18. PPOOLEX experiments on dynamic loading with pressure feedback

    Energy Technology Data Exchange (ETDEWEB)

    Puustinen, M.; Laine, J.; Raesaenen, A. (Lappeenranta Univ. of Technology, Nuclear Safety Research Unit (Finland))

    2011-01-15

    This report summarizes the results of the dynamic loading experiments (DYN series) carried out with the scaled down, two compartment PPOOLEX test facility designed and constructed at LUT. Steam was blown into the dry well compartment and from there through the DN200 vertical blowdown pipe to the condensation pool filled with sub-cooled water. The main purpose of the experiments was to study dynamic loads caused by different condensation modes. Particularly, the effect of counterpressure on loads due to pressure oscillations induced by chugging was of interest. Before the experiments the condensation pool was filled with isothermal water so that the blowdown pipe outlet was submerged by 1.03-1.11 m. The initial temperature of the pool water varied from 11 deg. C to 63 deg. C, the steam flow rate from 290 g/s to 1220 g/s and the temperature of incoming steam from 132 deg. C to 182 deg. C. Non-condensables were pushed from the dry well into the gas space of the wet well with a short discharge of steam before the recorded period of the experiments. As a result of this procedure, the system pressure was at an elevated level in the beginning of the actual experiments. An increased counterpressure was used in the last experiment of the series. The diminishing effect of increased system pressure on chugging intensity and on measured loads is evident from the results of the last experiment. The highest pressure pulses both inside the blowdown pipe and in the condensation pool were about half of those measured with a lower system pressure but otherwise with similar test parameters. The experiments on dynamic loading gave expected results. The loads experienced by pool structures depended strongly on the steam mass flow rate, pool water temperature and system pressure. The DYN experiments indicated that chugging and condensation within the blowdown pipe cause significant dynamic loads in case of strongly sub-cooled pool water. The level of pool water temperature is decisive

  19. C-188 Co-60 sources installation and source rack loading optimization processes in a gamma irradiation facility

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Paulo de S.; Vasquez, Pablo A.S., E-mail: psantos@ipen.br, E-mail: pavsalva@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-11-01

    Since 2004, the Multipurpose Gamma Facility at the Nuclear and Energy Research Institute has been providing services on radiation processing for disinfection and sterilization of health care and disposable medical products as well to support research studies on modification of physical, chemical and biological properties of several materials. Recently, there was an increment in irradiation of the Cultural Heritages. This facility uses C-188 double-encapsulated radioactive Cobalt-60 sources known as pencils from manufactures outside of country. The activity of the cobalt sources decays into a stable nickel isotope with a half-life around 5.27 years, which means a loss of 12.3% annually. Then, additional pencils of Cobalt-60 are added periodically to the source rack to maintain the required capacity or installed activity of the facility. The manufacturer makes shipping of the radioactive sources inside a high density container type B(U) , by sea. This one involves many administrative, transport and radiation safety procedures. Once in the facility, the container is opened inside a deep pool water to remove the pencils. The required source geometry of the facility is obtained by loading these source pencils into predetermined diagram or positions in source modules and distributing these modules over the source rack of the facility. The dose variation can be reduced placing the higher activity source pencils near the periphery of the source rack. In this work are presented the procedures for perform the boiling leaching tests applied to the container, the Cobalt-60 sources installation, the loading processes and the source rack loading optimization. (author)

  20. DEVELOPMENT OF THE TRU WASTE TRANSPORTATION FLEET--A SUCCESS STORY

    International Nuclear Information System (INIS)

    Devarakonda, Murthy; Morrison, Cindy; Brown, Mike

    2003-01-01

    Since March 1999, the Waste Isolation Pilot Plant (WIPP), located in southeastern New Mexico, has been operated by the U.S. Department of Energy (DOE), Carlsbad Field Office (CBFO), as a repository for the permanent disposal of defense-related transuranic (TRU) waste. More than 1,450 shipments of TRU waste for WIPP disposal have been completed, and the WIPP is currently receiving 12 to 16 shipments per week from five DOE sites around the nation. One of the largest fleets of Type B packagings supports the transportation of TRU waste to WIPP. This paper discusses the development of this fleet since the original Certificate of Compliance (C of C) for the Transuranic Package Transporter-II (TRUPACT-II) was issued by the U.S. Nuclear Regulatory Commission (NRC) in 1989. Evolving site programs, closure schedules of major sites, and the TRU waste inventory at the various DOE sites have directed the sizing and packaging mix of this fleet. This paper discusses the key issues that guided this fleet development, including the following: While the average weight of a 55-gallon drum packaging debris could be less than 300 pounds (lbs.), drums containing sludge waste or compacted waste could approach the maximum allowable weight of 1,000 lbs. A TRUPACT-II shipment may consist of three TRUPACT-II packages, each of which is limited to a total weight of 19,250 lbs. Payload assembly weights dictated by ''as-built'' TRUPACT-II weights limit each drum to an average weight of 312 lbs when three TRUPACT-IIs are shipped. To optimize the shipment of heavier drums, the HalfPACT packaging was designed as a shorter and lighter version of the TRUPACT-II to accommodate a heavier load. Additional packaging concepts are currently under development, including the ''TRUPACT-III'' packaging being designed to address ''oversized'' boxes that are currently not shippable in the TRUPACT-II or HalfPACT due to size constraints. Shipment optimization is applicable not only to the addition of new

  1. Transport aircraft loading and balancing system: Using a CLIPS expert system for military aircraft load planning

    Science.gov (United States)

    Richardson, J.; Labbe, M.; Belala, Y.; Leduc, Vincent

    1994-01-01

    The requirement for improving aircraft utilization and responsiveness in airlift operations has been recognized for quite some time by the Canadian Forces. To date, the utilization of scarce airlift resources has been planned mainly through the employment of manpower-intensive manual methods in combination with the expertise of highly qualified personnel. In this paper, we address the problem of facilitating the load planning process for military aircraft cargo planes through the development of a computer-based system. We introduce TALBAS (Transport Aircraft Loading and BAlancing System), a knowledge-based system designed to assist personnel involved in preparing valid load plans for the C130 Hercules aircraft. The main features of this system which are accessible through a convivial graphical user interface, consists of the automatic generation of valid cargo arrangements given a list of items to be transported, the user-definition of load plans and the automatic validation of such load plans.

  2. Functionalized PLA polymers to control loading and/or release properties of drug-loaded nanoparticles.

    Science.gov (United States)

    Thauvin, Cédric; Schwarz, Bettina; Delie, Florence; Allémann, Eric

    2017-11-15

    Advantages associated with the use of polylactic acid (PLA) nano- or microparticles as drug delivery systems have been widely proven in the field of pharmaceutical sciences. These biodegradable and biocompatible carriers have demonstrated different loading and release properties depending on interactions with the cargo, preparation methods, particles size or molecular weight of PLA. In this study, we sought to show the possibility of influencing these properties by modifying the structure of the constituting polymer. Seven non-functionalized or functionalized PLA polymers were specifically designed and synthesized by microwave-assisted ring-opening polymerization of d,l-lactide. They presented short hydrophobic and/or hydrophilic groups thanks to the use of C20 aliphatic chain, mPEG1000, sorbitan esters (Spans ® ) or polysorbates (Tweens ® ), their PEGylated analogues, as initiators. Then, seven types of drug-loaded nanoparticles (NP) were prepared from these polymers and compared in terms of physico-chemical characteristics, drug loading and release profiles. Although the loading properties were not improved with any of the functionalized PLA NP, different release profiles were observed in an aqueous medium at 37 °C and over a period of five days. The presence of PEG moieties in the core of PLA-polysorbates NP induced a faster release while the addition of a single aliphatic chain induced a slower release due to better interactions with the active molecule. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Study on load temperature control system of ground laser communication

    Science.gov (United States)

    Zhai, Xunhua; Zhang, Hongtao; Liu, Wangsheng; Zhang, Chijun; Zhou, Xun

    2007-12-01

    The ground laser communication terminal as the termination of a communication system, works at the temperature which varies from -40°C to 50°C. We design a temperature control system to keep optical and electronic components working properly in the load. The load is divided into two sections to control temperature respectively. Because the space is limited, we use heater film and thermoelectric cooler to clearify and refrigerate the load. We design a hardware and a software for the temperature control system, establish mathematic model, and emulate it with Matlab.

  4. MICROSTRUCTURE AND MECHANICAL STRENGTH OF SURFACE ODS TREATED ZIRCALOY-4 SHEET USING LASER BEAM SCANNING

    Directory of Open Access Journals (Sweden)

    HYUN-GIL KIM

    2014-08-01

    Full Text Available The surface modification of engineering materials by laser beam scanning (LBS allows the improvement of properties in terms of reduced wear, increased corrosion resistance, and better strength. In this study, the laser beam scan method was applied to produce an oxide dispersion strengthened (ODS structure on a zirconium metal surface. A recrystallized Zircaloy-4 alloy sheet with a thickness of 2 mm, and Y2O3 particles of 10 μm were selected for ODS treatment using LBS. Through the LBS method, the Y2O3 particles were dispersed in the Zircaloy-4 sheet surface at a thickness of 0.4 mm, which was about 20% when compared to the initial sheet thickness. The mean size of the dispersive particles was 20 nm, and the yield strength of the ODS treated plate at 500°C was increased more than 65 % when compared to the initial state. This strength increase was caused by dispersive Y2O3 particles in the matrix and the martensite transformation of Zircaloy-4 matrix by the LBS.

  5. High charge-discharge performance of Pb{sub 0.98}La{sub 0.02}(Zr{sub 0.35}Sn{sub 0.55}Ti{sub 0.10}){sub 0.995}O{sub 3} antiferroelectric ceramics

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Chenhong [Key Laboratory of Inorganic Functional Materials and Devices, Shanghai Institute of Ceramics, Chinese Academy of Sciences, 1295 Dingxi Road, Shanghai 200050 (China); University of the Chinese Academy of Sciences, Beijing 100049 (China); Liu, Zhen; Chen, Xuefeng; Yan, Shiguang; Cao, Fei; Dong, Xianlin; Wang, Genshui, E-mail: genshuiwang@mail.sic.ac.cn [Key Laboratory of Inorganic Functional Materials and Devices, Shanghai Institute of Ceramics, Chinese Academy of Sciences, 1295 Dingxi Road, Shanghai 200050 (China)

    2016-08-21

    The energy storage performance and charge-discharge properties of Pb{sub 0.98}La{sub 0.02}(Zr{sub 0.35}Sn{sub 0.55}Ti{sub 0.10}){sub 0.995}O{sub 3} (PLZST) antiferroelectric ceramics were investigated through directly measuring the hysteresis loops and pulse discharge current-time curves. The energy density only varies 0.2% per degree from 25 °C to 85 °C, and the energy efficiency maintains at about 90%. Furthermore, an approximate calculating model of maximum power density p{sub max} was established for the discharge process. Under a relatively high working electric field (8.2 kV/mm), this ceramics possess a greatly enhanced power density of 18 MW/cm{sup 3}. Moreover, the pulse power properties did not show degradation until 1500 times of charge-discharge cycling. The large released energy density, high energy efficiency, good temperature stability, greatly enhanced power density, and excellent fatigue endurance combined together make this PLZST ceramics an ideal candidate for pulse power applications.

  6. Current Trends and Challenges in Location-Based Services

    Directory of Open Access Journals (Sweden)

    Haosheng Huang

    2018-05-01

    Full Text Available Location-based services (LBS are a growing area of research. This editorial paper introduces the key research areas within the scientific field of LBS, which consist of positioning, modelling, communication, applications, evaluation, analysis of LBS data, and privacy and ethical issues. After that, 18 original papers are presented, which provide a general picture of recent research activities on LBS, especially related to the research areas of positioning, modelling, applications, and LBS data analysis. This Special Issue together with other recent events and publications concerning LBS show that the scientific field of LBS is rapidly evolving, and that LBS applications have become smarter and more ubiquitous in many aspects of our daily life.

  7. Room temperature neutron diffraction and magnetic studies of multiferroic Pb{sub 0.9}Bi{sub 0.1}Fe{sub 0.55}Nb{sub 0.45}O{sub 3} solid solution

    Energy Technology Data Exchange (ETDEWEB)

    Dadami, S. T.; Matteppanavar, S.; Shivaraja, I.; Angadi, B., E-mail: brangadi@gmail.com [Department of Physics, Bangalore University, Bangalore-560056 (India); Rayaprol, S.; Deshpande, S. K. [UGC-DAE-CSR, Mumbai Centre, BARC, Mumbai-400085 (India)

    2016-05-23

    The Pb{sub 0.9}Bi{sub 0.1}Fe{sub 0.55}Nb{sub 0.45}O{sub 3} (PBFNO) solid solution was synthesized by single step solid state reaction method and the optimized parameters are 700°C for 2hr (calcination) and 800°C for 3hr (sintering). The formation of desired material was confirmed using X-Ray Diffraction (XRD) and Neutron Diffraction (ND) studies. The structural and magnetic properties of the sintered pellets were investigated at room temperature (RT) through XRD, ND and Magnetic (M-H) studies. The structural analysis was carried out by Rietveld refinement through the Full Prof program. Rietveld refined XRD and ND patterns confirms the monoclinic structure with Cm space group and obtained cell parameters from the ND data are a = 5.651(2) Å, b = 5.658(2) Å, c = 4.005(1) Å and α = 90°, β = 89.98(1)°, γ = 90°. RT M-H curve studies have been carried out. It shows the clear opening of hysteresis (M–H) loop, is evidenced as the existence of weak ferromagnetism at RT. The M-H data shows existence weak ferromagnetism embedded in an antiferromagnetic matrix structure. The dielectric constant with frequency shows the formation of barrier layers at the grain and grain boundary interfaces gives rise to interfacial space charge polarization.

  8. Structural Impact of Construction Loads

    Science.gov (United States)

    2012-08-01

    Numerous bridge construction accidents have occurred across the country because of construction loadings, which are an underemphasized : topic in many DOT specifications and design manuals. Bridge girders are least stable when they are subjected to c...

  9. Curcumin-loaded chitosan-cholesterol micelles: evaluation in monolayers and 3D cancer spheroid model.

    Science.gov (United States)

    Muddineti, Omkara Swami; Kumari, Preeti; Ray, Eupa; Ghosh, Balaram; Biswas, Swati

    2017-06-02

    To improve the bioavailability and anticancer potential of curcumin by using a cholesterol-conjugated chitosan micelle. Methods & methods: Cholesterol was conjugated to chitosan (15 kDa) to form self-assembled micelles, which loaded curcumin. Physicochemical characterization and formulation optimization of the drug-loaded micelles (curcumin-loaded chitosan-cholesterol micelles [C-CCM]) were performed. In vitro cellular uptake and viability of C-CCM were investigated in melanoma and breast cancer cell lines. The antitumor efficacy was evaluated in 3D lung cancer spheroid model. The optimized C-CCM had size of approximately 162 nm with loading efficiency of approximately 36%. C-CCM was taken up efficiently by the cells, and it reduced cancer cell viability significantly compared with free curcumin. C-CCM enhanced the antitumor efficacy in spheroids, suggesting that C-CCM could be used as an effective chemotherapy in cancer.

  10. Cognitive Load Alters Neuronal Processing of Food Odors.

    Science.gov (United States)

    Hoffmann-Hensel, Sonja Maria; Sijben, Rik; Rodriguez-Raecke, Rea; Freiherr, Jessica

    2017-10-31

    Obesity is a major health concern in modern societies. Although decreased physical activity and enhanced intake of high-caloric foods are important risk factors for developing obesity, human behavior during eating also plays a role. Previous studies have shown that distraction while eating increases food intake and leads to impaired processing of food stimuli. As olfaction is the most important sense involved in flavor perception, we used functional magnetic resonance imaging techniques to investigate the influence of cognitive memory load on olfactory perception and processing. Low- and high-caloric food odors were presented in combination with either low or high cognitive loads utilizing a memory task. The efficacy of the memory task was verified by a decrease in participant recall accuracy and an increase in skin conductance response during high cognitive load. Our behavioral data reveal a diminished perceived intensity for low- but not high-caloric food odors during high cognitive load. For low-caloric food odors, bilateral orbitofrontal (OFC) and piriform cortices (pirC) showed significantly lower activity during high compared with low cognitive load. For high-caloric food odors, a similar effect was established in pirC, but not in OFC. Insula activity correlates with higher intensity ratings found during the low cognitive load condition. We conclude lower activity in pirC and OFC to be responsible for diminished intensity perception, comparable to results in olfactory impaired patients and elderly. Further studies should investigate the influence of olfactory/gustatory intensities on food choices under distraction with special regards to low-caloric food. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  11. cRGD-installed docetaxel-loaded mertansine prodrug micelles: redox-triggered ratiometric dual drug release and targeted synergistic treatment of B16F10 melanoma

    Science.gov (United States)

    Zhong, Ping; Qiu, Min; Zhang, Jian; Sun, Huanli; Cheng, Ru; Deng, Chao; Meng, Fenghua; Zhong, Zhiyuan

    2017-07-01

    Combinatorial chemotherapy, which has emerged as a promising treatment modality for intractable cancers, is challenged by a lack of tumor-targeting, robust and ratiometric dual drug release systems. Here, docetaxel-loaded cRGD peptide-decorated redox-activable micellar mertansine prodrug (DTX-cRGD-MMP) was developed for targeted and synergistic treatment of B16F10 melanoma-bearing C57BL/6 mice. DTX-cRGD-MMP exhibited a small size of ca. 49 nm, high DTX and DM1 loading, low drug leakage under physiological conditions, with rapid release of both DTX and DM1 under a cytoplasmic reductive environment. Notably, MTT and flow cytometry assays showed that DTX-cRGD-MMP brought about a synergistic antitumor effect to B16F10 cancer cells, with a combination index of 0.37 and an IC50 over 3- and 13-fold lower than cRGD-MMP (w/o DTX) and DTX-cRGD-Ms (w/o DM1) controls, respectively. In vivo studies revealed that DTX-cRGD-MMP had a long circulation time and a markedly improved accumulation in the B16F10 tumor compared with the non-targeting DTX-MMP control (9.15 versus 3.13% ID/g at 12 h post-injection). Interestingly, mice treated with DTX-cRGD-MMP showed almost complete growth inhibition of B16F10 melanoma, with tumor inhibition efficacy following an order of DTX-cRGD-MMP > DTX-MMP (w/o cRGD) > cRGD-MMP (w/o DTX) > DTX-cRGD-Ms (w/o DM1) > free DTX. Consequently, DTX-cRGD-MMP significantly improved the survival rates of B16F10 melanoma-bearing mice. Importantly, DTX-cRGD-MMP caused little adverse effects as revealed by mice body weights and histological analyses. The combination of two mitotic inhibitors, DTX and DM1, appears to be an interesting approach for effective cancer therapy.

  12. Eficiencia de los motores de inducción con carga cíclica; Efficiency of Induction Motors with Cyclic Load

    Directory of Open Access Journals (Sweden)

    Elías de la Rosa Masdueño

    2011-02-01

    Full Text Available Se propone un nuevo método para determinar la eficiencia de trabajo de los motores de inducción queaccionan cargas cíclicas tales como bombas reciprocantes, martinetes, etc. El método se basa en lasegregación de pérdidas, y la determinación del gráfico de corriente y la energía total del ciclo. Se muestrauna comprobación experimental basada en un método de Monte Carlo.  A new method for finding the working efficiency of the induction motors moving cyclic loads is proposed.This type of loading is frequent in mechanism like piston pumps, hammers, etc. The method is based inthe losses segregation and the determination of the current graphic and the total energy in the cycle. Anexperimental proof based on Monte Carlo method is shown.

  13. 75 FR 40729 - Residues of Quaternary Ammonium Compounds, N-Alkyl (C12-14

    Science.gov (United States)

    2010-07-14

    ... the Daily Dietary Dose (DDD) and the Estimated Daily Intake (EDI) using modified Food and Drug... survey days. The Estimated Daily Intake (EDI) calculations presented in this assessment for treated... is 0.0103 lbs a.i per gallon of treatment solution. EDI values were calculated using an approach...

  14. CFD Study of a New Annular Lift Fan Configuration with High Lift Efficiency

    Directory of Open Access Journals (Sweden)

    Yun Jiang

    2017-03-01

    Full Text Available A new annular lift fan configuration that has very high lift efficiency is explored by using a numerical scheme. The inlet lip radius and diffuser angle are maximized by semicircle duct walls and the location of the lift fan is moved from the throat to the diffuser area to maximize the diffusion effect of the ducted fan. The improved lift fan achieves the figure of merit of 0.772 and the power loading of 9.03 lbs/hp without ground effect, very close to the theoretical limit. Under the ground effect, the figure of merit reaches 0.822 with the power loading of 9.62 lbs/hp. The improved lift efficiency deteriorates the transition characteristics with higher momentum drag and pitching moment. However, with the aid of jet thrusts directly providing part of the lift during transition, the peak of momentum drag and pitching moment can be lowered. A total thrust to weight ratio of 0.7 is enough for all of the requirements in transition and in hover and for the maximum speed of 0.75 Mach in cruise flight.

  15. An update on blast furnace granular coal injection

    Energy Technology Data Exchange (ETDEWEB)

    Hill, D.G. [Bethlehem Steel Corp., Burns Harbor, IN (United States); Strayer, T.J.; Bouman, R.W. [Bethlehem Steel Corp., PA (United States)

    1997-12-31

    A blast furnace coal injection system has been constructed and is being used on the furnace at the Burns Harbor Division of Bethlehem Steel. The injection system was designed to deliver both granular (coarse) and pulverized (fine) coal. Construction was completed on schedule in early 1995. Coal injection rates on the two Burns Harbor furnaces were increased throughout 1995 and was over 200 lbs/ton on C furnace in September. The injection rate on C furnace reached 270 lbs/ton by mid-1996. A comparison of high volatile and low volatile coals as injectants shows that low volatile coal replaces more coke and results in a better blast furnace operation. The replacement ratio with low volatile coal is 0.96 lbs coke per pound of coal. A major conclusion of the work to date is that granular coal injection performs very well in large blast furnaces. Future testing will include a processed sub-bituminous coal, a high ash coal and a direct comparison of granular versus pulverized coal injection.

  16. Tapping insertional torque allows prediction for better pedicle screw fixation and optimal screw size selection.

    Science.gov (United States)

    Helgeson, Melvin D; Kang, Daniel G; Lehman, Ronald A; Dmitriev, Anton E; Luhmann, Scott J

    2013-08-01

    specimen. Each pedicle was incrementally tapped to increasing size (3.75, 4.00, 4.50, and 5.50 mm) until the threshold value was reached based on the assigned group. Pedicle screw size was determined by adding 1 mm to the tap size that crossed the threshold torque value. Torque measurements were recorded with each revolution during tap and pedicle screw insertion. Each specimen was then individually potted and pedicle screws pulled out "in-line" with the screw axis at a rate of 0.25 mm/sec. Peak pullout strength (POS) was measured in Newtons (N). The peak tapping IT was significantly increased (50%) in Group 2 (3.23 ± 0.65 in-lbs) compared with Group 1 (2.15 ± 0.56 in-lbs) (p=.0005). The peak screw IT was also significantly increased (19%) in Group 2 (8.99 ± 2.27 in-lbs) compared with Group 1 (7.52 ± 2.96 in-lbs) (p=.02). The pedicle screw pullout strength was also significantly increased (23%) in Group 2 (877.9 ± 235.2 N) compared with Group 1 (712.3 ± 223.1 N) (p=.017). The mean pedicle screw diameter was significantly increased in Group 2 (5.70 ± 1.05 mm) compared with Group 1 (5.00 ± 0.80 mm) (p=.0002). There was also an increased rate of optimal pedicle screw size selection in Group 2 with 9 of 15 (60%) pedicle screws compared with Group 1 with 4 of 15 (26.7%) pedicle screws within 1 mm of the measured pedicle width. There was a moderate correlation for tapping IT with both screw IT (r=0.54; p=.002) and pedicle screw POS (r=0.55; p=.002). Our findings suggest that tapping IT directly correlates with pedicle screw IT, pedicle screw pullout strength, and optimal pedicle screw size. Therefore, tapping IT may be used during thoracic pedicle screw instrumentation as an adjunct to preoperative imaging and clinical experience to maximize fixation strength and optimize pedicle "fit and fill" with the largest screw possible. However, further prospective, in vivo studies are necessary to evaluate the intraoperative use of tapping IT to predict screw loosening

  17. Fracture behaviour of a self-healing microcapsule-loaded epoxy system

    Directory of Open Access Journals (Sweden)

    2011-03-01

    Full Text Available The effect of temperature on the fracture behaviour of a microcapsule-loaded epoxy matrix was investigated. Microencapsulated epoxy and mercaptan-derivative healing agents were incorporated into an epoxy matrix to produce a polymer composite capable of self-healing. Maximum fracture loads were measured using the double-torsion method. Thermal aging at 55 and 110°C for 17 hours [hrs] was applied to heal the pre-cracked samples. The addition of microcapsules appeared to increase significantly the load carrying capacity of the epoxy after healing. Once healed, the composites achieved as much as 93–171% of its virgin maximum fracture load at 18, 55 and 110°C. The fracture behavior of the microcapsule- loaded epoxy matrix was influenced by the healing temperature. The high self-healing efficiency may be attributed to the result of the subsurface micro-crack pinning or deviation, and to a stronger microencapsulated epoxy and mercaptanderivative binder than that of the bulk epoxy. The results show that the healing temperature has a significant effect on recovery of load transferring capability after fracture.

  18. Dicty_cDB: Contig-U08321-1 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available 1 ( ES461930 ) piTB021xJ01.b1.ab1 PiTB - Interaction library bet... 42 7.7 1 >( AU271578 ) Dictyostelium dis...us chromosome UNKNOWN clone CH261-68A2... 44 2.0 1 ( ES463131 ) piTB023xL02.b1.ab1 PiTB - Interaction library... bet... 44 2.0 1 ( ES456862 ) piTE013xM13.b2.ab1 PiTE - Interaction library bet... 44 2.0 1 ( ES454806 ) pi...TE007xI05.b1.ab1 PiTE - Interaction library bet... 44 2.0 1 ( EG562612 ) CRS1002G...ng caudal f... 34 0.55 2 ( CK829647 ) Fr_Fwd_06A05_T3 Forward subtracted cDNA library

  19. Effect of transient heating loads on beryllium

    International Nuclear Information System (INIS)

    Kupriyanov, Igor B.; Porezanov, Nicolay P.; Nikolaev, Georgyi N.; Kurbatova, Liudmila A.; Podkovyrov, Vyacheslav L.; Muzichenko, Anatoliy D.; Zhitlukhin, Anatoliy M.; Khimchenko, Leonid N.; Gervash, Alexander A.

    2014-01-01

    Highlights: • We study the effect of transient plasma loads on beryllium erosion and surface microstructure. • Beryllium targets were irradiated by plasma streams with energy of 0.5–1 MJ/m 2 at ∼250 °C. • Under plasma loads 0.5–1 MJ/m 2 cracking of beryllium surface is rather slight. • Under 0.5 MJ/m 2 the mass loss of Be is no more than 0.2 g/m 2 shot and decreasing with shots number. • Under 1 MJ/m 2 maximum mass loss of beryllium was 3.7 g/m 2 shot and decreasing with shots number. - Abstract: Beryllium will be used as a plasma facing material for ITER first wall. It is expected that erosion of beryllium under transient plasma loads such as the edge-localized modes (ELMs) and disruptions will mainly determine a lifetime of ITER first wall. The results of recent experiments with the Russian beryllium of TGP-56FW ITER grade on QSPA-Be plasma gun facility are presented. The Be/CuCrZr mock-ups were exposed to upto 100 shots by deuterium plasma streams with pulse duration of 0.5 ms at ∼250 °C and average heat loads of 0.5 and 1 MJ/m 2 . Experiments were performed at 250 °C. The evolution of surface microstructure and cracks morphology as well as beryllium mass loss are investigated under erosion process

  20. Reduction of date microbial load with ozone

    Science.gov (United States)

    Farajzadeh, Davood; Qorbanpoor, Ali; Rafati, Hasan; Isfeedvajani, Mohsen Saberi

    2013-01-01

    Background: Date is one of the foodstuffs that are produced in tropical areas and used worldwide. Conventionally, methyl bromide and phosphine are used for date disinfection. The toxic side effects of these usual disinfectants have led food scientists to consider safer agents such as ozone for disinfection, because food safety is a top priority. The present study was performed to investigate the possibility of replacing common conventional disinfectants with ozone for date disinfection and microbial load reduction. Materials and Methods: In this experimental study, date samples were ozonized for 3 and 5 hours with 5 and 10 g/h concentrations and packed. Ozonized samples were divided into two groups and kept in an incubator which was maintained at 25°C and 40°C for 9 months. During this period, every 3 month, microbial load (bacteria, mold, and yeast) were examined in ozonized and non-ozonized samples. Results: This study showed that ozonization with 5 g/h for 3 hours, 5 g/h for 5 hours, 10 g/h for 3 hours, and 10 g/h for 5 hours leads to about 25%, 25%, 53%, and 46% reduction in date mold and yeast load and about 6%, 9%, 76%, and 74.7% reduction in date bacterial load at baseline phase, respectively. Appropriate concentration and duration of ozonization for microbial load reduction were 10 g/h and 3 hours. Conclusion: Date ozonization is an appropriate method for microbial load reduction and leads to an increase in the shelf life of dates. PMID:24124432

  1. Intracavity irradiation with deferred radioactive load technique, remote control high activity sources

    Energy Technology Data Exchange (ETDEWEB)

    Badell, M.; Lejarcegui, J.A.; Guix, B.; Rubio, A.; Pons, F.; Farrus, B.

    1988-01-01

    From December 1981 to September 1986, 149 patients were treated at the Radiotherapy Department of the Hospital Clinico y Provincial of Barcelona by means of intracavity irradiation with 137 cesium high 1 sources and 2. To 112 of the total number of patients external radiotherapy to the whole of the pelvis using photons of 6 MeV was also administered. A total of 46 (30.7%) patients presented rectal complications. The rectitis observed was mild in 16 cases (10.7%), moderate in 15(10%) and severe in 15(10%). The 15 patients with severe rectitis had to be treated by unloading colostomy. In patients with severe complications, the maximum total rectal dose administered was between 5,855 and 9,490 cGy, and the maximum rectal dose administered via curietherapy was 1,055 to 7,320 cGy. Maximum total rectal dose administration greater than 4,000 cGy and maximum rectal dose administered via curietherapy greater than 5,800 cGy were statistically significant prognostic factors (p < 0.001) of severe rectal complications.

  2. Intracavitary irradiation with deferred radioactive load Technique, remote control high activity sources

    International Nuclear Information System (INIS)

    Badell, M.; Lejarceguir, J.A.; Guix, B.; Rubio, A.; Pons, A.; Farrus, B.

    1988-01-01

    From december 1981 to septembre 1986, 149 patients were treated at the Radiotherapy Department of the Hospital Clinico y Provincial of Barcelona by means of intracavitary irradiation with 137 cesium high 1 sources and 2. To 112 of the total number of patients external radiotherapy to the whole of the pelvis using photons of 6 MeV was also administered. A total of 46 (30.7%) patients presented rectal complications. The rectitis observed was mild in 16 cases (10.7%). moderate in 15 (10%) and severe in 15 15(10%) and severe in 15(10%). The 15 patients with severe rectitis had to be treated by unloading colostomy. In patients with severe complications, the maximum total rectal dose administered was between 5,855 and 9,490 cGy, and the maximum rectal dose administered via curietherapy was 1.055 to 7.320 cGy. Maximum total rectal dose administration greater than 4, cGy and maximum rectal dose administered via curietherapy greater than 5,800 cGy were statistically significant prognostic factors (p0.001) of severe rectal complications. (Author)

  3. Consideration of higher seismic loads at existing plants

    Energy Technology Data Exchange (ETDEWEB)

    Liebig, J.; Pellissetti, M.

    2015-07-01

    Because of advancement of methods in probabilistic seismic hazard analysis, plenty of existing plants face higher seismic loads as an obligation from the national authorities. In case of such obligations safety related structures and equipment have to be reevaluated or requalified for the increased seismic loads. The paper provides solutions for different kinds of structures and equipment inside the plant, avoiding cost intensive hardware exchange. Due to higher seismic loads different kinds of structures and equipment inside a plant have to be reevaluated. For civil structures, primary components, mechanical components, distribution lines and electrical and I&C equipment different innovative concepts will be applied to keep structures and equipment qualified for the higher seismic loads. Detailed analysis, including the modeling of non-linear phenomena, or minor structural upgrades are cost competitive, compared to cost intensive hardware exchanges. Several case studies regarding the re-evaluation and requalification of structures and equipment due to higher seismic loads are presented. It is shown how the creation of coupled finite element models and the consistent propagation of acceleration time histories through the soil, building and primary circuit lead to a significant load reduction Electrical and I&C equipment is reinforced by smart upgrades which increase the natural equipment frequencies. Therefore for all devices inside the cabinets the local acceleration will not increase and the seismic qualification will be maintained. The case studies cover both classical deterministic and probabilistic re-evaluations (fragility analysis). Furthermore, the substantial benefits of non-linear limit load evaluation, such as push-over analysis of buildings and limit load analysis of fuel assemblies, are demonstrated. (Author)

  4. Bone healing response in cyclically loaded implants: Comparing zero, one, and two loading sessions per day.

    Science.gov (United States)

    de Barros E Lima Bueno, Renan; Dias, Ana Paula; Ponce, Katia J; Wazen, Rima; Brunski, John B; Nanci, Antonio

    2018-05-31

    When bone implants are loaded, they are inevitably subjected to displacement relative to bone. Such micromotion generates stress/strain states at the interface that can cause beneficial or detrimental sequels. The objective of this study is to better understand the mechanobiology of bone healing at the tissue-implant interface during repeated loading. Machined screw shaped Ti implants were placed in rat tibiae in a hole slightly bigger than the implant diameter. Implants were held stable by a specially-designed bone plate that permits controlled loading. Three loading regimens were applied, (a) zero loading, (b) one daily loading session of 60 cycles with an axial force of 1.5 N/cycle for 7 days, and (c) two such daily sessions with the same axial force also for 7 days. Finite element analysis was used to characterize the mechanobiological conditions produced by the loading sessions. After 7 days, the implants with surrounding interfacial tissue were harvested and processed for histological, histomorphometric and DNA microarray analyses. Histomorphometric analyses revealed that the group subjected to repeated loading sessions exhibited a significant decrease in bone-implant contact and increase in bone-implant distance, as compared to unloaded implants and those subjected to only one loading session. Gene expression profiles differed during osseointegration between all groups mainly with respect to inflammatory and unidentified gene categories. The results indicate that increasing the daily cyclic loading of implants induces deleterious changes in the bone healing response, most likely due to the accumulation of tissue damage and associated inflammatory reaction at the bone-implant interface. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  5. [Optimization of trehalose loading in red blood cells before freeze-drying].

    Science.gov (United States)

    Zhuang, Yuan; Liu, Jing-Han; Ouyang, Xi-Lin; Chen, Lin-Feng; Che, Ji

    2007-04-01

    The key points for better protection of trehalose in freeze-drying red blood cells (RBCs) are to resolve non-osmosis of trehalose to red blood cells and to make cytoplasmic trehalose to reach effective concentration. This study was aimed to investigate the regularity of loading RBCs with trehalose, screen out optimal loading condition and evaluate the effect of trehalose on physico-chemical parameters of RBCs during the period of loading. The cytoplasmic trehalose concentration in red blood cells, free hemoglobin and ATP level were determined at different incubation temperatures (4, 22 and 37 degrees C), different trehaolse concentrations (0, 200, 400, 600, 800 and 1000 mmol/L) and different incubation times (2, 4, 6, 8 and 10 hours), the cytoplasmic trehalose, free hemoglobin (FHb), hemoglobin (Hb) and mean corpuscular volume (MCV) in fresh RBCs and RBCs stored for 72 hours at 4 degrees C were compared, when loading condition was ensured. The results showed that with increase of incubation temperature, time and extracellular trehalose concentration, the loading of trehalose in RBCs also increased. Under the optimal loading condition, cytoplasmic trehalose concentration and free hemoglobin level of fresh RBCs and RBCs stored for 72 hours at 4 degrees C were 65.505 +/- 6.314 mmol/L, 66.2 +/- 5.002 mmol/L and 6.567 +/- 2.568 g/L, 16.168 +/- 3.922 g/L respectively. It is concluded that the most optimal condition of loading trehalose is that fresh RBCs incubate in 800 mmol/L trehalose solution for 8 hours at 37 degrees C. This condition can result in a efficient cytoplasmic trehalose concentration. The study provides an important basis for long-term preservation of RBCs.

  6. Influence of sweeping detonation-wave loading on damage evolution during spallation loading of tantalum in both a planar and curved geometry

    Energy Technology Data Exchange (ETDEWEB)

    Gray, George Thompson III [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Hull, Lawrence Mark [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Livescu, Veronica [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Faulkner, James [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Briggs, Matthew E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Meyer, Ross Keith [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Andrews, Heather Lynn [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Hare, Steven John [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Jakulewicz, Micah Shawn [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Shinas, Michael A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-03-30

    Widespread research over the past five decades has provided a wealth of experimental data and insight concerning the shock hardening, damage evolution, and the spallation response of materials subjected to square-topped shock-wave loading profiles. However, fewer quantitative studies have been conducted on the effect of direct, in-contact, high explosive (HE)-driven Taylor wave (unsupported shocks) loading on the shock hardening, damage evolution, or spallation response of materials. Systematic studies quantifying the effect of sweeping-detonation wave loading are yet sparser. In this study, the damage evolution and spallation response of Ta is shown to be critically dependent on the peak shock stress, the geometry of the sample (flat or curved plate geometry), and the shock obliquity during sweeping-detonation-wave shock loading. Sweepingwave loading in the flat-plate geometry is observed to: a) yield a lower spall strength than previously documented for 1-D supported-shock-wave loading, b) exhibit increased shock hardening as a function of increasing obliquity, and c) lead to an increased incidence of deformation twin formation with increasing shock obliquity. Sweeping-wave loading of a 10 cm radius curved Ta plate is observed to: a) lead to an increase in the shear stress as a function of increasing obliquity, b) display a more developed level of damage evolution, extensive voids and coalescence, and lower spall strength with obliquity in the curved plate than seen in the flat-plate sweeping-detonation wave loading for an equivalent HE loading, and c) no increased propensity for deformation twin formation with increasing obliquity as seen in the flat-plate geometry. The overall observations comparing and contrasting the flat versus curved sweeping-wave spall experiments with 1D loaded spallation behavior suggests a coupled influence of obliquity and geometry on dynamic shock-induced damage evolution and spall strength. Coupled experimental and modeling research

  7. 2007 Global Demilitarization Symposium and Exhibition

    Science.gov (United States)

    2007-05-17

    Directorate Design Development - Cryofracture Subsystem - • Munitions Preparation Trailer – Munition loading fixtures to ensure proper orientation – Conveyor ...in cryobath – Empty fixture return heater – Conveyor to transfer munitions to Cryofracture Press Trailer • Cryofracture Press Trailer – 3.0 lbs. (TNT...diverters to separate fracture munitions into four feed chutes – Press munitions loader robot to transfer munitions to press Energetics, Warheads

  8. Effect of reference loads on fracture mechanics analysis of surface cracked pipe based on reference stress method

    International Nuclear Information System (INIS)

    Shim, Do Jun; Son, Beom Goo; Kim, Young Jin; Kim, Yun Jae

    2004-01-01

    To investigate relevance of the definition of the reference stress to estimate J and C * for surface crack problems, this paper compares FE J and C * results for surface cracked pipes with those estimated according to the reference stress approach using various definitions of the reference stress. Pipes with part circumferential inner surface crack and finite internal axial crack are considered, subject to internal pressure and global bending. The crack depth and aspect ratio are systematically varied. The reference stress is defined in four different ways using (I) the local limit load, (II) the global limit load, (III) the global limit load determined from the FE limit analysis, and (IV) the optimised reference load. It is found that the reference stress based on the local limit load gives overall excessively conservative estimates of J and C * . Use of the global limit load clearly reduces the conservatism, compared to that of the local limit load, although it can provide sometimes non-conservative estimates of J and C * . The use of the FE global limit load gives overall non-conservative estimates of J and C * . The reference stress based on the optimised reference load gives overall accurate estimates of J and C * , compared to other definitions of the reference stress. Based on the present finding, general guidance on the choice of the reference stress for surface crack problems is given

  9. Environmental Assessment: 2005 Base Realignment and Closure Seymour Johnson Air Force Base Goldsboro, North Carolina

    Science.gov (United States)

    2007-07-01

    aquatica), red maple (Acer rubrum), and loblolly pine ( Pinus taeda) are also present. • Coastal Plain Small Stream Swamp: Degraded examples of this...Daily Permit Limit (lbs/hr) Emissions (lbs/hr) (lbs/hr) Emissions (lbs/day) Emissions (lbs/day) (lbs/day) Ethyl Acetate 0 0 481.8 - - -- Methyl Ethyl...Ketone 0.54 1.08 34.1 2.7 5.4 76.2 Methyl Isobutyl Ketone 0.41 0.82 105.6 2.05 4.1 2247.7 Toluene 0.71 1.42 23.8 3.55 7.1 571.4 Xylene 0.33 0.66

  10. A damage cumulation method for crack initiation prediction under non proportional loading and overloading

    International Nuclear Information System (INIS)

    Taheri, S.

    1992-04-01

    For a sequence of constant amplitude cyclic loading containing overloads, we propose a method for damage cumulation in non proportional loading. This method uses as data cyclic stabilized states at non proportional loading and initiation or fatigue curve in uniaxial case. For that, we take into account the dependence of Cyclic Strain Stress Curves (C.S.S.C.) and mean cell size on prehardening and we define a stabilized uniaxial state cyclically equivalent to a non proportional stabilized state through a family of C.S.S.C. Although simple assumptions like linear damage function and linear cumulation is used we obtain a sequence effect for difficult cross slip materials as 316 stainless steel, but the Miner rule for easy cross-slip materials. We show then differences between a load-controlled test and a strain controlled test: for a 316 stainless steel in a load controlled test, the non proportional loading at each cycle is less damaging than the uniaxial one for the same equivalent stress, while the result is opposite in a strain controlled test. We show also that an overloading retards initiation in a load controlled test while it accelerates initiation in a strain controlled test. (author). 26 refs., 8 figs

  11. Reliability-Based Modeling of Moisture and Load-Duration Effects

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard; Svensson, Staffan

    2005-01-01

    Load duration effects with respect to reduction of load bearing capacity are very important for structural timber. This paper describes how the load duration effects combined with moisture content and variations c an be determined on basis of simulation of realizations of the time varying load...... and moisture processes. Permanent and snow load sand moisture variations are considered and stochastic models are formulated in accordance with the load models in the Danish structural codes. A damage accumulation model based on fracture mechanics that accounts for both load duration and moisture effects...... is derived. The parameters in the model are fitted to data relevant for Nordic structural timber using the Maximum Likelihood method. The probability of failure as function of time is estimated for representative limit states based on: a) short term strength and b) long term damage accumulation...

  12. High cycle fatigue of austenitic stainless steels under random loading

    International Nuclear Information System (INIS)

    Gauthier, J.P.; Petrequin, P.

    1987-08-01

    To investigate reactor components, load control random fatigue tests were performed at 300 0 C and 550 0 C, on specimens from austenitic stainless steels plates in the transverse orientation. Random solicitations are produced on closed loop servo-hydraulic machines by a mini computer which generates random load sequence by the use of reduced Markovian matrix. The method has the advantage of taking into account the mean load for each cycle. The solicitations generated are those of a stationary gaussian process. Fatigue tests have been mainly performed in the endurance region of fatigue curve, with scattering determination using stair case method. Experimental results have been analysed aiming at determining design curves for components calculations, depending on irregularity factor and temperature. Analysis in term of mean square root fatigue limit calculation, shows that random loading gives more damage than constant amplitude loading. Damage calculations following Miner rule have been made using the probability density function for the case where the irregularity factor is nearest to 100 %. The Miner rule is too conservative for our results. A method using design curves including random loading effects with irregularity factor as an indexing parameter is proposed

  13. Anti-obesity effect of a novel caffeine-loaded dissolving microneedle patch in high-fat diet-induced obese C57BL/6J mice.

    Science.gov (United States)

    Dangol, Manita; Kim, Suyong; Li, Cheng Guo; Fakhraei Lahiji, Shayan; Jang, Mingyu; Ma, Yonghao; Huh, Inyoung; Jung, Hyungil

    2017-11-10

    Natural products such as caffeine have been found to be effective in reducing body weight through lipolysis. Here, we report the successful loading of caffeine onto dissolving microneedle following inhibition of its crystal growth by hyaluronic acid (HA), the matrix material of the dissolving microneedle (DMN). Further, the anti-obesity activity of caffeine was evaluated in high-fat diet-induced obese C57BL/6J mice. After 6weeks of caffeine loaded dissolving microneedle patch (CMP) administration, lipolysis improved significantly as shown by leptin and adiponectin activity, which resulted in considerable weight loss of about 12.8±0.75% in high-fat diet-induced obese mice. Comparison of the levels of triglyceride, total cholesterol, high-density lipoprotein (HDL)-cholesterol, and low-density lipoprotein (LDL)-cholesterol after CMP administration with the initial levels in obese mice indicated significant anti-obesity activity of CMP. These findings suggested that a novel CMP with an increased amount of caffeine loaded onto DMN has therapeutic activity against obesity. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Initial transformer sizing for single-phase residential load

    International Nuclear Information System (INIS)

    Schneider, K.C.; Hoad, R.F.

    1992-01-01

    The purchase of distribution transformers represents a significant capital investment per year for an electric utility. Choosing the correct thermal and economic size transformer can help control this investment. This paper describes a method for determining the correct economic size of distribution transformers using end-use appliance load profiles and the ANSI/IEEE Standard C57.91-1981 thermal model. Although applied only to single family and multifamily residential load in this paper, the method can be extended to other types of load such as commercial or industrial

  15. A Study of the Insulin and the C-Peptide Responses to Oral Glucose Load in Nondiabetic and Diabetic Subjects

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Myung Chul; Choi, Sung Jae; Kim, Eung Jin; Koh, Chang Soon; Min, Hun Ki [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1977-03-15

    The present study was undertaken to evaluate the significance of the insulin and the C-peptide response to oral glucose loads in normal and diabetic subjects and to establish the effects of the obesity. In this study, the authors have measured plasma insulin and C-peptide by means of radioimmunoassay in 10 nonobese normal, 5 obese normal, 13 nonobese moderate diabetic patients, 9 obese moderate diabetic patients and 9 severe diabetic patients. The results obtained were as follows; 1) In 10 nonobese normal subjects, the plasma insulin level at fasting state and at 30, 60, 90, and 120 min after oral glucose loads were 15.7+-3.4, 48.3+-9.8, 40.4+-6.7, 37.4+-6.5 and 26.0+-4.2 uU/ml (Mean+-S.E.) and C-peptide were 1.9+-0.3, 3.9+-0.6, 6.3+-0.6, 5.7+-0.5 and 4.0+-0.5 ng/ml. The change of C-peptide was found to go almost parallel with that of insulin and the insulin value reaches to the highest level at 30 min whereas C-peptide reaches to its peak at 60 min.. 2) The plasma insulin level in 5 obese normal subjects were 38.9+-12.3, 59.5+-12.3, 59.2+-17.1, 56.1+-20.0 and 48.4+-17.2 uU/ml and the C-peptide were 5.5+-0.4, 6.8+-0.5, 7.9+-0.8, 7.9+-0.8 and 7.8+-2.0 ng/ml. The insulin response appeared to be greater than nonobese normal subjects. 3) In 13 nonobese moderate diabetic patients, the plasma insulin levels were 27.1+-4.9, 44.1+-6.0, 37.3+-6.6, 35.5+-8.1 and 34.7+-10.7 uU/ml and the C-peptide levels were 2.7+-0.4, 4.9+-0.7, 6.5+-0.5, 7.0+-0.3 and 6.7+-1.0 ng/ml. There was little significance compared to nonobese normal groups but delayed pattern is noted. 4) In 9 obese moderated diabetic patients, the plasma insulin levels were 22.1+-7.9, 80.0+-19.3, 108.0+-27.0, 62.0+-17.6 and 55.5+-10.l uU/ml and the C-peptide levels were 5.2+-0.4, 8.0+-1.0, 10.4+-1.6, 10.4+-1.7 and 10.1+-1.0 ng/ml and its response was also greater than that of nonobese moderate diabetic patients. 5) The plasma insulin concentrations in 9 severe diabetic subjects were 8.0+-3.8, 12.1+-3.5, 16.8+-4.6, 19

  16. Effects of cyclic tensile loading on stress corrosion cracking susceptibility for sensitized Type 304 stainless steel in 290 C high purity water

    International Nuclear Information System (INIS)

    Takaku, H.; Tokiwai, M.; Hirano, H.

    1979-01-01

    The effects of load waveform on intergranular stress corrosion cracking (IGSCC) susceptibility have been examined for sensitized Type 304 stainless steels in a 290 C high purity water loop. Concerning the strain rate in the trapezoidal stress waveform, it was found that IGSCC susceptibility was higher for smaller values of the strain rate. It was also shown that IGSCC susceptibility became higher when the holding time at the upper stress was prolonged, and when the upper stress was high. The occurrence of IGSCC for sensitized Type 304 stainless steel became easy due to the application of cyclic tensile stress in 290 C high purity water

  17. Market and own load bulletin - December 1993

    International Nuclear Information System (INIS)

    1993-12-01

    The electric power consumption in the residential, commercial and industrial Brazilian sectors and in the five Brazilian regions during december of 1993 is described. The industrial production indexes, the cost of tariffs and fuel consumption and the evolution of own load energy and the energy demand are also shown. (C.G.C.)

  18. Market and own load bulletin - December 1992

    International Nuclear Information System (INIS)

    1992-12-01

    The electric power consumption in the residential, commercial and industrial Brazilian sectors and in the five Brazilian regions during december of 1992 is described. The industrial production indexes, the cost of tariffs and fuel consumption and the evolution of own load energy and the energy demand are also shown. (C.G.C.)

  19. Transposing Concentration-Discharge Curves onto Unmonitored Catchments to Estimate Seasonal Nutrient Loads

    Science.gov (United States)

    Minaudo, C.; Moatar, F.; Abbott, B. W.; Dupas, R.; Gascuel-Odoux, C.; Pinay, G.; Roubeix, V.; Danis, P. A.

    2017-12-01

    Many lakes and reservoirs in Europe suffer from severe eutrophication. Accurate quantification of nutrient loads are critical for effective mitigation measures, but this information is often unknown. For example, in France, only 50 out of 481 lakes and reservoirs have national monitoring allowing estimation of interannual nitrogen and phosphorus loads, and even these loads are computed from low-frequency data. To address this lack of data, we developed a straightforward method to predict seasonal loads in lake tributaries. First, we analyzed concentration-discharge (C-Q) curves in monitored catchments and identified slopes, intercepts, and coefficient of variation of the log(C)-log(Q) regressions determined for both low and high flows, separated by the median daily flow [Moatar et al., 2017]. Then, we used stepwise multiple linear regression models to empirically link the characteristics of C-Q curves with a set of catchment descriptors such as land use, lithology, morphology indices, climate, and hydrological indicators. Modeled C-Q relationships were then used to estimate annual and seasonal nutrient loads in nearby and similar unmonitored catchments. We implemented this approach on a large dataset from France where stream flow was surveyed daily and water quality (suspended solids, nitrate, total phosphorus, and orthophosphate concentrations) was measured on a monthly basis at 233 stations over the past 20 years in catchments from 10 to 3000 km². The concentration at the median daily flow (seen here as a metric of the general level of contamination in a catchment) was predicted with uncertainty ranging between 30 and 100 %, depending on the variable. C-Q slopes were predicted with large errors, but a sensitivity analysis was conducted to determine the impact of C-Q slopes uncertainties on computed annual and seasonal loads. This approach allows estimation of seasonal and annual nutrient loads and could be potentially implemented to improve protection and

  20. Runoff quality and pollution loadings from a tropical urban catchment.

    Science.gov (United States)

    Yusop, Z; Tan, L W; Ujang, Z; Mohamed, M; Nasir, K A

    2005-01-01

    Runoff quality draining from 17.14 km2 urban catchment in Johor Bahru, Malaysia, was analysed. The land-use consists of residential (30.3%), agricultural (27.3%), open space (27.9%), industrial (8.1%) and commercial (6.4%) areas. Three storm events were sampled in detail. These storms produced stormflow between 0.84 mm and 27.82 mm, and peakflow from 2.19 m3/s to 42.36 m3/s. Water quality showed marked variation during storms especially for TSS, BOD and COD with maximum concentrations of 778 mg/l, 135 mg/l and 358 mg/l, respectively. Concentrations of TOC, DOC, NH3-N, Fe and level of colour were also high. In general, the river quality is badly polluted and falls in Class V based on the Malaysian Interim National Water Quality Standards. Event Mean Concentrations (EMC) for various parameters varied considerably between storms. The largest storm produced higher EMC for TSS, NO3-N and SS whereas the smaller storms tend to register higher EMC for BOD, COD, NH3-N, TOC, Ca, K, Mg, Fe and Zn. Such variations could be explained in terms of pollutant availability and the effects of flushing and dilution. Based on a three-month average recurrence interval (ARI) of rainfall, the estimated event loadings (ton/ha) of TSS, BOD, COD, TOC, NH3-N and NO3-N were 0.055, 0.016, 0.012, 0.039, 0.010, 0.0007 and 0.0002, respectively. Heavy metals present in trace quantities. Storms with 3 months ARI could capture about 70% of the total annual loads of major pollutants.

  1. Strength Testing in the Air Force: Current Processes and Suggestions for Improvements

    Science.gov (United States)

    2014-01-01

    administered at the MEPS (their names are excluded to protect confidentiality ). We also thank the career field managers who participated in our interviews...machine (140–150 lbs) an average, adult, American woman (140–160 lbs) an average, adult, American man (170–190 lbs) an average, freestanding kitchen ...an average, adult, American woman (140–160 lbs) an average, adult, American man (170–190 lbs) an average, freestanding kitchen range and oven

  2. Women in Combat: Issues for Congress

    Science.gov (United States)

    2016-12-13

    Heavy (black) Standing long jump 120 cm 140 cm 160 cm Seated power throw (4.4 lbs medicine ball) 350 cm 400 cm 450 cm Strength deadlift 120 lbs...140 lbs 160 lbs Interval run (20- meter course) 36 shuttles 40 shuttles 43 shuttles 101 Army MEDCOM...30-lbs ammo-can lifts Timed 880- yard sprint Timed 300- yard shuttle run Standard IST 2 (men) 12 second flexed arm hang (women) 1.5 miles in

  3. Results of the radiological survey at 10 Long Valley Road, Lodi, New Jersey (LJ055)

    International Nuclear Information System (INIS)

    Foley, R.D.; Floyd, L.M.; Carrier, R.F.

    1989-11-01

    Maywood Chemical Works (MCW) of Maywood, New Jersey, generated process wastes and residues associated with the production and refining of thorium and thorium compounds from monazite ores from 1916 to 1956. MCW supplied rare earth metals and thorium compounds to the Atomic Energy Commission and various other government agencies from the late 1940s to the mid-1950s. Area residents used the sandlike waste from this thorium extraction process mixed with tea and cocoa leaves as mulch in their yards. Some of these contaminated wastes were also eroded from the site into Lodi Brook. At the request of the US Department of Energy (DOE), a group from Oak Ridge National Laboratory conducts investigative radiological surveys of properties in the vicinity of MCW to determine whether a property is contaminated with radioactive residues, principally 232 Th, derived from the MCW site. The survey typically includes direct measurement of gamma radiation levels and soil sampling for radionuclide analyses. The survey of this site, 10 Long Valley Road, Lodi, New Jersey (LJ055), was conducted during 1985 and 1986. Results of the survey demonstrated no radionuclide concentrations in excess of the DOE Formerly Utilized Sites Remedial Action Program criteria. The radionuclide distributions were not significantly different from normal background levels in the northern New Jersey area. 4 refs., 5 figs., 3 tabs

  4. Development of nuclear rocket engine technology

    International Nuclear Information System (INIS)

    Gunn, S.V.

    1989-01-01

    Research sponsored by the Atomic Energy Commission, the USAF, and NASA (later on) in the area of nuclear rocket propulsion is discussed. It was found that a graphite reactor, loaded with highly concentrated Uranium 235, can be used to heat high pressure liquid hydrogen to temperatures of about 4500 R, and to expand the hydrogen through a high expansion ratio rocket nozzle assembly. The results of 20 reactor tests conducted at the Nevada Test Site between July 1959 and June 1969 are analyzed. On the basis of these results, the feasibility of solid graphite reactor/nuclear rocket engines is revealed. It is maintained that this technology will support future space propulsion requirements, using liquid hydrogen as the propellant, for thrust requirements ranging from 25,000 lbs to 250,000 lbs, with vacuum specific impulses of at least 850 sec and with full engine throttle capability. 12 refs

  5. High power s-band vacuum load

    Energy Technology Data Exchange (ETDEWEB)

    Neubauer, Michael [Muons, Inc., Batavia, IL (United States); Dudas, Alan [Muons, Inc., Batavia, IL (United States); Krasnykh, Anatoly [SLAC National Accelerator Lab., Menlo Park, CA (United States)

    2016-12-29

    Through a combination of experimentation and calculation the components of a novel room temperature dry load were successfully fabricated. These components included lossy ceramic cylinders of various lengths, thicknesses, and percent of silicon carbide (SiC). The cylinders were then assembled into stainless steel compression rings by differential heating of the parts and a special fixture. Post machining of this assembly provided a means for a final weld. The ring assemblies were then measured for S-parameters, individually and in pairs using a low-cost TE10 rectangular to TE01 circular waveguide adapter specially designed to be part of the final load assembly. Matched pairs of rings were measured for assembly into the final load, and a sliding short designed and fabricated to assist in determining the desired short location in the final assembly. The plan for the project was for Muons, Inc. to produce prototype loads for long-term testing at SLAC. The STTR funds for SLAC were to upgrade and operate their test station to ensure that the loads would satisfy their requirements. Phase III was to be the sale to SLAC of loads that Muons, Inc. would manufacture. However, an alternate solution that involved a rebuild of the old loads, reduced SLAC budget projections, and a relaxed time for the replacement of all loads meant that in-house labor will be used to do the upgrade without the need for the loads developed in this project. Consequently, the project was terminated before the long term testing was initiated. However, SLAC can use the upgraded test stand to compare the long-term performance of the ones produced in this project with their rebuilt loads when they are available.

  6. High power s-band vacuum load

    International Nuclear Information System (INIS)

    Neubauer, Michael; Dudas, Alan; Krasnykh, Anatoly

    2016-01-01

    Through a combination of experimentation and calculation the components of a novel room temperature dry load were successfully fabricated. These components included lossy ceramic cylinders of various lengths, thicknesses, and percent of silicon carbide (SiC). The cylinders were then assembled into stainless steel compression rings by differential heating of the parts and a special fixture. Post machining of this assembly provided a means for a final weld. The ring assemblies were then measured for S-parameters, individually and in pairs using a low-cost TE10 rectangular to TE01 circular waveguide adapter specially designed to be part of the final load assembly. Matched pairs of rings were measured for assembly into the final load, and a sliding short designed and fabricated to assist in determining the desired short location in the final assembly. The plan for the project was for Muons, Inc. to produce prototype loads for long-term testing at SLAC. The STTR funds for SLAC were to upgrade and operate their test station to ensure that the loads would satisfy their requirements. Phase III was to be the sale to SLAC of loads that Muons, Inc. would manufacture. However, an alternate solution that involved a rebuild of the old loads, reduced SLAC budget projections, and a relaxed time for the replacement of all loads meant that in-house labor will be used to do the upgrade without the need for the loads developed in this project. Consequently, the project was terminated before the long term testing was initiated. However, SLAC can use the upgraded test stand to compare the long-term performance of the ones produced in this project with their rebuilt loads when they are available.

  7. Optimization of cryoprotectant loading into murine and human oocytes.

    Science.gov (United States)

    Karlsson, Jens O M; Szurek, Edyta A; Higgins, Adam Z; Lee, Sang R; Eroglu, Ali

    2014-02-01

    Loading of cryoprotectants into oocytes is an important step of the cryopreservation process, in which the cells are exposed to potentially damaging osmotic stresses and chemical toxicity. Thus, we investigated the use of physics-based mathematical optimization to guide design of cryoprotectant loading methods for mouse and human oocytes. We first examined loading of 1.5 M dimethyl sulfoxide (Me(2)SO) into mouse oocytes at 23°C. Conventional one-step loading resulted in rates of fertilization (34%) and embryonic development (60%) that were significantly lower than those of untreated controls (95% and 94%, respectively). In contrast, the mathematically optimized two-step method yielded much higher rates of fertilization (85%) and development (87%). To examine the causes for oocyte damage, we performed experiments to separate the effects of cell shrinkage and Me(2)SO exposure time, revealing that neither shrinkage nor Me(2)SO exposure single-handedly impairs the fertilization and development rates. Thus, damage during one-step Me(2)SO addition appears to result from interactions between the effects of Me(2)SO toxicity and osmotic stress. We also investigated Me(2)SO loading into mouse oocytes at 30°C. At this temperature, fertilization rates were again lower after one-step loading (8%) in comparison to mathematically optimized two-step loading (86%) and untreated controls (96%). Furthermore, our computer algorithm generated an effective strategy for reducing Me(2)SO exposure time, using hypotonic diluents for cryoprotectant solutions. With this technique, 1.5 M Me(2)SO was successfully loaded in only 2.5 min, with 92% fertilizability. Based on these promising results, we propose new methods to load cryoprotectants into human oocytes, designed using our mathematical optimization approach. Copyright © 2013 Elsevier Inc. All rights reserved.

  8. Effect of loading rate on creep of phosphorous doped copper

    Energy Technology Data Exchange (ETDEWEB)

    Andersson-Oestling, Henrik C.M.; Sandstroem, Rolf (Swerea KIMAB (Sweden))

    2011-12-15

    Creep testing of copper intended for nuclear waste disposal has been performed on continuous creep tests machines at a temperature of 75 deg C. The loading time has been varied from 1 hour to 6 months. The rupture strain including both loading and creep strains does not differ from traditional dead weight lever creep test rigs. The loading strain increases with increasing loading time, at the expense of the creep strain. The time dependence of the creep strain has been modelled taking athermal plastic deformation and creep into account. During loading the contribution to the strain from the athermal plastic deformation dominates until the stress is close to the constant load level. When the constant load has been reached there is no more athermal strain and all of the strain comes from creep

  9. Market and own load bulletin - October 1993

    International Nuclear Information System (INIS)

    1993-01-01

    The electric power consumption in the residential, commercial and industrial Brazilian sectors, and in the five Brazilian regions, during January-October 93, and November 92-October 93 is described. The industrial production indexes, the cost of tariffs and fuel consumption, the evolution of own load energy and energy demand are also shown. (C.G.C.)

  10. Market and own load bulletin - June 1993

    International Nuclear Information System (INIS)

    1993-06-01

    The electric power consumption in the residential, commercial and industrial Brazilian sectors and in the five Brazilian regions during the month of June 1993 is described. The industrial production indexes, the cost of tariffs and fuel consumption and the evolution of own load energy and the energy demand are also shown. (C.G.C.)

  11. Market and own load bulletin - August 1993

    International Nuclear Information System (INIS)

    1993-08-01

    The electric power consumption in the residential, commercial and industrial Brazilian sectors and in the five Brazilian regions during the month of August 1993 is described. The industrial production indexes, the cost of tariffs and fuel consumption and the evolution of own load energy and the energy demand are also shown. (C.G.C.)

  12. Market and own load bulletin - November 1993

    International Nuclear Information System (INIS)

    1993-01-01

    The electric power consumption in the residential, commercial and industrial Brazilian sectors, and in the five Brazilian regions, during January-November 93, and December 92-November 93 is described. The industrial production indexes, the cost of tariffs and fuel consumption, the evolution of own load energy and energy demand are also shown. (C.G.C.)

  13. Market and own load bulletin - July 1993

    International Nuclear Information System (INIS)

    1993-07-01

    The electric power consumption in the residential, commercial and industrial Brazilian sectors and in the five Brazilian regions during the month of July 1993 is described. The industrial production indexes, the cost of tariffs and fuel consumption and the evolution of own load energy and the energy demand are also shown. (C.G.C.)

  14. Load research manual. Volume 1. Load research procedures

    Energy Technology Data Exchange (ETDEWEB)

    Brandenburg, L.; Clarkson, G.; Grund, Jr., C.; Leo, J.; Asbury, J.; Brandon-Brown, F.; Derderian, H.; Mueller, R.; Swaroop, R.

    1980-11-01

    This three-volume manual presents technical guidelines for electric utility load research. Special attention is given to issues raised by the load data reporting requirements of the Public Utility Regulatory Policies Act of 1978 and to problems faced by smaller utilities that are initiating load research programs. In Volumes 1 and 2, procedures are suggested for determining data requirements for load research, establishing the size and customer composition of a load survey sample, selecting and using equipment to record customer electricity usage, processing data tapes from the recording equipment, and analyzing the data. Statistical techniques used in customer sampling are discussed in detail. The costs of load research also are estimated, and ongoing load research programs at three utilities are described. The manual includes guides to load research literature and glossaries of load research and statistical terms.

  15. Design-Load Basis for LANL Structures, Systems, and Components

    Energy Technology Data Exchange (ETDEWEB)

    I. Cuesta

    2004-09-01

    This document supports the recommendations in the Los Alamos National Laboratory (LANL) Engineering Standard Manual (ESM), Chapter 5--Structural providing the basis for the loads, analysis procedures, and codes to be used in the ESM. It also provides the justification for eliminating the loads to be considered in design, and evidence that the design basis loads are appropriate and consistent with the graded approach required by the Department of Energy (DOE) Code of Federal Regulation Nuclear Safety Management, 10, Part 830. This document focuses on (1) the primary and secondary natural phenomena hazards listed in DOE-G-420.1-2, Appendix C, (2) additional loads not related to natural phenomena hazards, and (3) the design loads on structures during construction.

  16. Functional adaptation to mechanical loading in both cortical and cancellous bone is controlled locally and is confined to the loaded bones.

    Science.gov (United States)

    Sugiyama, Toshihiro; Price, Joanna S; Lanyon, Lance E

    2010-02-01

    In order to validate whether bones' functional adaptation to mechanical loading is a local phenomenon, we randomly assigned 21 female C57BL/6 mice at 19 weeks of age to one of three equal numbered groups. All groups were treated with isoflurane anesthesia three times a week for 2 weeks (approximately 7 min/day). During each anaesthetic period, the right tibiae/fibulae in the DYNAMIC+STATIC group were subjected to a peak dynamic load of 11.5 N (40 cycles with 10-s intervals between cycles) superimposed upon a static "pre-load" of 2.0 N. This total load of 13.5 N engendered peak longitudinal strains of approximately 1400 microstrain on the medial surface of the tibia at a middle/proximal site. The right tibiae/fibulae in the STATIC group received the static "pre-load" alone while the NOLOAD group received no artificial loading. After 2 weeks, the animals were sacrificed and both tibiae, fibulae, femora, ulnae and radii analyzed by three-dimensional high-resolution (5 mum) micro-computed tomography (microCT). In the DYNAMIC+STATIC group, the proximal trabecular percent bone volume and cortical bone volume at the proximal and middle levels of the right tibiae as well as the cortical bone volume at the middle level of the right fibulae were markedly greater than the left. In contrast, the left bones in the DYNAMIC+STATIC group showed no differences compared to the left or right bones in the NOLOAD or STATIC group. These microCT data were confirmed by two-dimensional examination of fluorochrome labels in bone sections which showed the predominantly woven nature of the new bone formed in the loaded bones. We conclude that the adaptive response in both cortical and trabecular regions of bones subjected to short periods of dynamic loading, even when this response is sufficiently vigorous to stimulate woven bone formation, is confined to the loaded bones and does not involve changes in other bones that are adjacent, contra-lateral or remote to them. (c) 2009 Elsevier Inc

  17. Secure and privacy-enhancing LBS

    OpenAIRE

    Jin, Hongyu

    2013-01-01

    The rapid growth of population and the increasing number of vehicles haveled to high accident rates and cause frequently traffic congestion, especiallyin densely populated countries. There is an urgent need to develop and deployIntelligent Transport Systems (ITSs), in order to improve traffic efficiencyand reduce traffic accidents. The emergence and development of advancedtechnologies lays a good foundation for ITSs; for example, wireless communicationand sensing technologies. To promote the ...

  18. Modelling of Structural Loads in Drag Augmented Space Debris Removal Concepts

    DEFF Research Database (Denmark)

    Kristensen, Anders Schmidt; Nikolajsen, Jan Ánike; Lauridsen, Peter Riddersholm

    2017-01-01

    A Self-deployable Deorbiting Space Structure (SDSS) is used for drag augmented space debris removal. A highly flexible frame allows for a folding of the structure by bifurcation. This research models the structural loads during the deployment and unfolding of the drag sail in Low Earth Orbit (LEO......). The Spacecraft travels with 7.8 km/s at deployment. As the drag sail unfolds instantaneously the structure must withstand the loads from the unfolding and the drag. Thermal loads are included in the FEA as the temperature varies from -80°C to +80°C during deorbit. The results are used to verify the structural...

  19. Relationship between changes of blood HBV-DNA viral load and serum liver fibrosis markers (HA, LN, IV-C, PCIII) levels in patients with chronic hepatitis B

    International Nuclear Information System (INIS)

    Wang Yuanchi; Huang Jinwei

    2009-01-01

    Objective: To investigate the relationship between changes of blood HBV DNA viral load and serum liver fibrosis markers levels in patients with chronic hepatitis B. Methods: In 2002, 20 patients with hepatitis B were divided into two groups: Group A treated with antiviral ageat (n=10), Group B not treated.Five years later (2007) the blood viral load (with FQ-PCR) and serum levels of hepatic fibrosis markers (with RIA) were determined in these patients. Results: The average log viral load in serum in the tow groups were 3.56 ± 1.12 (treated group) and 7.76 ± 1.23 respectively with significant difference (P<0.05). In 2002, serum liver fibrosis markers (HA, LN, IV-C, PCIII) levels were about the same in the two groups were (82.72 ± 30.62μg/ml, 71.18 ± 26.71μg/ml, 93.77 ± 69.87μg/ml, 91.4 ± 18.64μg/ml and 79.32 ± 31.34μg/ml, 70.25 ± 28.23)μg/ml, 90.35 ± 67.81μg/ml, 85.77 ± 20.56μg/ml respectively). In 2007, in the treated patients, serum liver fibrosis markers HA, LN, IV-C, PCIII levels were 85.72 ± 29.52μg/ml, 70.18 ± 25.4μg/ml, 94.2 ± 70.92μg/ml, 93.4 ± 19.32μg/ml respectively However, in the non-treated groups, the serum HA, LN, IV-C, PCIII levels were105.67 ± 28.54μg/ml, 97.75 ± 26.25μg/ml, 132 ± 72.13μg/ml, 120.72 ± 19.87μg/ml, being significantly higher than those in the treated group (P<0.05). Conclusion: Effective decrease of the viral load might control the progress of hepatic fibrosis in patients with chronic hepatitis B. (authors)

  20. Impact Analysis of Reinforced Concrete Columns with Side Openings Subjected to Eccentric Axial Loads

    Directory of Open Access Journals (Sweden)

    Nazar Kamil Ali

    2015-02-01

    Full Text Available In this research the behavior of reinforced concrete columns with large side openings under impact loads was studied. The overall cross sectional dimensions of the column specimens used in this research were (500*1400 mm with total height of (14000 mm. The dimensions of side openings were (600*2000 mm. The column was reinforced with (20 mm diameter in longitudinal direction, while (12 mm ties were used in the transverse direction. The effect of eccentric impact loads on the horizontal and vertical displacement for this column was studied. Nonlinear finite element analysis has been carried out using ready computer finite element package (ANSYS to simulate the behavior of the reinforced concrete column with large side openings. Two load cases were considered in this investigation (C1, C2 with three different load values for each case. In the first case (C1 the loads was applied to one side of the column and in the second case (C2 the loads was applied to both sides. An Equilateral triangular load-time function was used for simulation the impact load results from gantry cranes supported by the column with total time duration (0.1 sec. In order to verify the analysis method, as no experimental data exist for comparing the obtained results, another analysis is made for tested conventional column under impact load at mid-height and good agreement has been obtained. For the above mentioned column, the maximum displacements were (33.3, 22.2 mm in the horizontal and longitudinal direction respectively, location of the maximum horizontal displacement was at the crown of the column. By comparing the results of the first loading case with the second one it is shown that in the horizontal direction, maximum displacement increases by (139%, (208%, and (147% respectively, also the maximum vertical displacement increases by (150%, (172%, and (172% respectively.

  1. Load power device, system and method of load control and management employing load identification

    Science.gov (United States)

    Yang, Yi; Luebke, Charles John; Schoepf, Thomas J.

    2018-01-09

    A load power device includes a power input, at least one power output for at least one load, a plurality of sensors structured to sense voltage and current at the at least one power output, and a processor. The processor provides: (a) load identification based upon the sensed voltage and current, and (b) load control and management based upon the load identification.

  2. Effect of second-phase particles on the properties of W-based materials under high-heat loading

    Directory of Open Access Journals (Sweden)

    Xiao–Yue Tan

    2016-12-01

    Full Text Available W, W-TaC, and W-TiC materials were subjected to heat–load tests in an electron beam facility (10keV, 8kW at 100 pulses. After heat loading, severe cracks and plastic deformation were detected on the surface of pure W materials. However, plastic deformation was the primary change on the surfaces of W-TaC and W-TiC alloys. This phenomenon was due to the second-phase (TaC and TiC particles dispersed in the W matrix, which strengthened the grain boundaries and prevented crack formation and propagation. In addition, the microhardness of W and W-TiC obviously decreased, whereas that of W-TaC did not change considerably before and after heat loading.

  3. Magnetic phase diagram of ErNi2B2C

    DEFF Research Database (Denmark)

    Jensen, A.; Toft, K.N.; Abrahamsen, A.B.

    2004-01-01

    The magnetic phase diagram of the superconductor ErNi2B2C (T-c = 11 K and T-N = 6 K) has been studied by neutron diffraction as a function of temperature and magnetic field applied along the symmetry directions [010], [110] and [001] of the tetragonal crystal structure. A series of commensurate...... magnetic structures, consistent with a transversely polarized spin-density wave with modulation vectors Q = n/ma* (0.55 less than or equal to n/m field model that has been established from...... an analysis of bulk magnetization and zero-field neutron diffraction data. The model accounts for most of the observed features but fails to explain the occurrence of a small component Qdelta approximate to -0.005b* observed close to H-c2 when the field is applied along [110]. (C) 2004 Elsevier B.V. All...

  4. Degradation forecast for PEMFC cathode-catalysts under cyclic loads

    Science.gov (United States)

    Moein-Jahromi, M.; Kermani, M. J.; Movahed, S.

    2017-08-01

    Degradation of Fuel Cell (FC) components under cyclic loads is one of the biggest bottlenecks in FC commercialization. In this paper, a novel experimental based algorithm is presented to predict the Catalyst Layer (CL) performance loss during cyclic load. The algorithm consists of two models namely Models 1 and 2. The Model 1 calculates the Electro-Chemical Surface Area (ECSA) and agglomerate size (e.g. agglomerate radius, rt,agg) for the catalyst layer under cyclic load. The Model 2 is the already-existing model from our earlier studies that computes catalyst performance with fixed structural parameters. Combinations of these two Models predict the CL performance under an arbitrary cyclic load. A set of parametric/sensitivity studies is performed to investigate the effects of operating parameters on the percentage of Voltage Degradation Rate (VDR%) with rank 1 for the most influential one. Amongst the considered parameters (such as: temperature, relative humidity, pressure, minimum and maximum voltage of the cyclic load), the results show that temperature and pressure have the most and the least influences on the VDR%, respectively. So that, increase of temperature from 60 °C to 80 °C leads to over 20% VDR intensification, the VDR will also reduce 1.41% by increasing pressure from 2 atm to 4 atm.

  5. Effect of Physical Load on Aerobic Exercise Performance during Heat Stress.

    Science.gov (United States)

    Kenefick, Robert W; Heavens, Kristen R; Luippold, Adam J; Charkoudian, Nisha; Schwartz, Steven A; Cheuvront, Samuel N

    2017-12-01

    This study aimed to investigate the effect of increasing external loads on 5-km treadmill time trial (TT) performance in 20°C and 40°C environmental conditions and to construct an ecologically relevant performance prediction decision aid. Twenty-six male and four female volunteers (age, 23.5 ± 6.9 yr; weight, 76.0 ± 8.9 kg; height, 1.75 ± 0.07 m; V˙O2peak, 50.7 ± 4.5 mL·kg·min) participated in a counterbalanced, mixed-model design, with each subject assigned to a load group (20%, 30%, or 50% body mass (BM); n = 10 per group). Volunteers performed three, self-paced 5-km familiarization TT (treadmill) without external load. Each volunteer then performed a 5-km TT in each environment with loads of either 20% (n = 10), 30% (n = 10), or 50% (n = 10) of BM. 1) Loads of (20%, 30%, and 50% of BM) impaired 5-km TT performance compared with that when unloaded (P exercise trials, an ecologically valid decision aid was developed from self-paced data, in which pace (km·h) can be predicted for individual levels of heat, load, or heat + load in combination.

  6. Time domain calculation of connector loads of a very large floating structure

    Science.gov (United States)

    Gu, Jiayang; Wu, Jie; Qi, Enrong; Guan, Yifeng; Yuan, Yubo

    2015-06-01

    Loads generated after an air crash, ship collision, and other accidents may destroy very large floating structures (VLFSs) and create additional connector loads. In this study, the combined effects of ship collision and wave loads are considered to establish motion differential equations for a multi-body VLFS. A time domain calculation method is proposed to calculate the connector load of the VLFS in waves. The Longuet-Higgins model is employed to simulate the stochastic wave load. Fluid force and hydrodynamic coefficient are obtained with DNV Sesam software. The motion differential equation is calculated by applying the time domain method when the frequency domain hydrodynamic coefficient is converted into the memory function of the motion differential equation of the time domain. As a result of the combined action of wave and impact loads, high-frequency oscillation is observed in the time history curve of the connector load. At wave directions of 0° and 75°, the regularities of the time history curves of the connector loads in different directions are similar and the connector loads of C1 and C2 in the X direction are the largest. The oscillation load is observed in the connector in the Y direction at a wave direction of 75° and not at 0°. This paper presents a time domain calculation method of connector load to provide a certain reference function for the future development of Chinese VLFS

  7. Prototype 350 MHz niobium spoke-loaded cavities

    International Nuclear Information System (INIS)

    Delayen, J. R.; Kedzie, M.; Mammosser, J.; Piller, C.; Shepard, K. W.

    1999-01-01

    This paper reports the development of 350 MHz superconducting cavities of a spoke-loaded geometry, intended for the velocity range 0.2 < v/c < 0.6. Two prototype single-cell cavities have been designed, one optimized for velocity v/c = 0.4, and the other for v/c = 0.29. Construction of the prototype niobium cavities is nearly complete. Details of the design and construction are discussed, along with the results of cold tests

  8. Prototype 350 MHz niobium spoke-loaded cavities.

    Energy Technology Data Exchange (ETDEWEB)

    Delayen, J. R.; Kedzie, M.; Mammosser, J.; Piller, C.; Shepard, K. W.

    1999-05-10

    This paper reports the development of 350 MHz superconducting cavities of a spoke-loaded geometry, intended for the velocity range 0.2 < v/c < 0.6. Two prototype single-cell cavities have been designed, one optimized for velocity v/c = 0.4, and the other for v/c = 0.29. Construction of the prototype niobium cavities is nearly complete. Details of the design and construction are discussed, along with the results of cold tests.

  9. Surface structural damage study in cortical bone due to medical drilling.

    Science.gov (United States)

    Tavera R, Cesar G; De la Torre-I, Manuel H; Flores-M, Jorge M; Hernandez M, Ma Del Socorro; Mendoza-Santoyo, Fernando; Briones-R, Manuel de J; Sanchez-P, Jorge

    2017-05-01

    A bone's fracture could be produced by an excessive, repetitive, or sudden load. A regular medical practice to heal it is to fix it in two possible ways: external immobilization, using a ferule, or an internal fixation, using a prosthetic device commonly attached to the bone by means of surgical screws. The bone's volume loss due to this drilling modifies its structure either in the presence or absence of a fracture. To observe the bone's surface behavior caused by the drilling effects, a digital holographic interferometer is used to analyze the displacement surface's variations in nonfractured post-mortem porcine femoral bones. Several nondrilled post-mortem bones are compressed and compared to a set of post-mortem bones with a different number of cortical drillings. During each compression test, a series of digital interferometric holograms were recorded using a high-speed CMOS camera. The results are presented as pseudo 3D mesh displacement maps for comparisons in the physiological range of load (30 and 50 lbs) and beyond (100, 200, and 400 lbs). The high resolution of the optical phase gives a better understanding about the bone's microstructural modifications. Finally, a relationship between compression load and bone volume loss due to the drilling was observed. The results prove that digital holographic interferometry is a viable technique to study the conditions that avoid the surgical screw from loosening in medical procedures of this kind.

  10. A Study of the Insulin and the C-Peptide Responses to Oral Glucose Load in Nondiabetic and Diabetic Subjects

    International Nuclear Information System (INIS)

    Lee, Myung Chul; Choi, Sung Jae; Kim, Eung Jin; Koh, Chang Soon; Min, Hun Ki

    1977-01-01

    The present study was undertaken to evaluate the significance of the insulin and the C-peptide response to oral glucose loads in normal and diabetic subjects and to establish the effects of the obesity. In this study, the authors have measured plasma insulin and C-peptide by means of radioimmunoassay in 10 nonobese normal, 5 obese normal, 13 nonobese moderate diabetic patients, 9 obese moderate diabetic patients and 9 severe diabetic patients. The results obtained were as follows; 1) In 10 nonobese normal subjects, the plasma insulin level at fasting state and at 30, 60, 90, and 120 min after oral glucose loads were 15.7±3.4, 48.3±9.8, 40.4±6.7, 37.4±6.5 and 26.0±4.2 uU/ml (Mean±S.E.) and C-peptide were 1.9±0.3, 3.9±0.6, 6.3±0.6, 5.7±0.5 and 4.0±0.5 ng/ml. The change of C-peptide was found to go almost parallel with that of insulin and the insulin value reaches to the highest level at 30 min whereas C-peptide reaches to its peak at 60 min.. 2) The plasma insulin level in 5 obese normal subjects were 38.9±12.3, 59.5±12.3, 59.2±17.1, 56.1±20.0 and 48.4±17.2 uU/ml and the C-peptide were 5.5±0.4, 6.8±0.5, 7.9±0.8, 7.9±0.8 and 7.8±2.0 ng/ml. The insulin response appeared to be greater than nonobese normal subjects. 3) In 13 nonobese moderate diabetic patients, the plasma insulin levels were 27.1±4.9, 44.1±6.0, 37.3±6.6, 35.5±8.1 and 34.7±10.7 uU/ml and the C-peptide levels were 2.7±0.4, 4.9±0.7, 6.5±0.5, 7.0±0.3 and 6.7±1.0 ng/ml. There was little significance compared to nonobese normal groups but delayed pattern is noted. 4) In 9 obese moderated diabetic patients, the plasma insulin levels were 22.1±7.9, 80.0±19.3, 108.0±27.0, 62.0±17.6 and 55.5±10.l uU/ml and the C-peptide levels were 5.2±0.4, 8.0±1.0, 10.4±1.6, 10.4±1.7 and 10.1±1.0 ng/ml and its response was also greater than that of nonobese moderate diabetic patients. 5) The plasma insulin concentrations in 9 severe diabetic subjects were 8.0±3.8, 12.1±3.5, 16.8±4.6, 19

  11. Fracture load of different crown systems on zirconia implant abutments.

    Science.gov (United States)

    Albrecht, T; Kirsten, A; Kappert, H F; Fischer, H

    2011-03-01

    The purpose of this study was to evaluate the fracture load of single zirconia abutment restorations using different veneering techniques and materials. The abutment restorations were divided into 6 groups with 20 samples each: test abutments (control group A), lithium disilicate ceramic crowns bonded on incisor abutments (group B), leucite ceramic crowns bonded on incisor abutments (group C), premolar abutments directly veneered with a fluor apatite ceramic (group D (layered) and group E (pressed)) and premolar abutments bonded with lithium disilicate ceramic crowns (group F). The fracture load of the restorations was evaluated using a universal testing machine. Half of each group was artificially aged (chewing simulation and thermocycling) before evaluating the fracture load with the exception of the test abutments. The fracture load of the test abutments was 705 ± 43N. Incisor abutments bonded with lithium disilicate or leucite ceramic crowns (groups B and C) showed fracture loads of about 580N. Premolar restorations directly veneered with fluor apatite ceramic (groups D and E) showed fracture loads of about 850N. Premolar restorations bonded with lithium disilicate ceramic crowns (group F) showed fracture loads of about 1850N. The artificial ageing showed no significant influence on the strength of the examined restorations. All ceramic crowns made of lithium disilicate glass-ceramic, adhesively bonded to premolar abutments showed the highest fracture loads in this study. However, all tested groups can withstand physiological bite forces. Copyright © 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  12. Sediment and Hydraulic Measurements with Computed Bed Load on the Missouri River, Sioux City to Hermann, 2014

    Science.gov (United States)

    2017-05-01

    ER D C /C HL T R- 17 -8 Sediment and Hydraulic Measurements with Computed Bed Load on the Missouri River , Sioux City to Hermann, 2014...Hydraulic Measurements with Computed Bed Load on the Missouri River , Sioux City to Hermann, 2014 David Abraham, Marielys Ramos-Villanueva, Thad Pratt...Engineers, Omaha and Kansas City Districts, in quantifying sediment bed load and suspended load at several sites on the Missouri River for the

  13. 75 FR 14116 - Approval of Implementation Plans of Wisconsin: Nitrogen Oxides Reasonably Available Control...

    Science.gov (United States)

    2010-03-24

    ... utility coal fired boilers to account for installation and electric reliability needs. All emission.... Wall-fired (low heat release), 0.15 lbs/mmBtu. Wall-fired (high heat release), 0.17 lbs/mmBtu. Cyclone.../ Tangential-fired, 0.15 lbs/mmBtu. hr. Wall-fired (low heat release), 0.15 lbs/mmBtu. Wall-fired (high heat...

  14. Daily Air Temperature and Electricity Load in Spain.

    Science.gov (United States)

    Valor, Enric; Meneu, Vicente; Caselles, Vicente

    2001-08-01

    Weather has a significant impact on different sectors of the economy. One of the most sensitive is the electricity market, because power demand is linked to several weather variables, mainly the air temperature. This work analyzes the relationship between electricity load and daily air temperature in Spain, using a population-weighted temperature index. The electricity demand shows a significant trend due to socioeconomic factors, in addition to daily and monthly seasonal effects that have been taken into account to isolate the weather influence on electricity load. The results indicate that the relationship is nonlinear, showing a `comfort interval' of ±3°C around 18°C and two saturation points beyond which the electricity load no longer increases. The analysis has also revealed that the sensitivity of electricity load to daily air temperature has increased along time, in a higher degree for summer than for winter, although the sensitivity in the cold season is always more significant than in the warm season. Two different temperature-derived variables that allow a better characterization of the observed relationship have been used: the heating and cooling degree-days. The regression of electricity data on them defines the heating and cooling demand functions, which show correlation coefficients of 0.79 and 0.87, and predicts electricity load with standard errors of estimate of ±4% and ±2%, respectively. The maximum elasticity of electricity demand is observed at 7 cooling degree-days and 9 heating degree-days, and the saturation points are reached at 11 cooling degree-days and 13 heating degree-days, respectively. These results are helpful in modeling electricity load behavior for predictive purposes.

  15. Erosion of beryllium under ITER – Relevant transient plasma loads

    International Nuclear Information System (INIS)

    Kupriyanov, I.B.; Nikolaev, G.N.; Kurbatova, L.A.; Porezanov, N.P.; Podkovyrov, V.L.; Muzichenko, A.D.; Zhitlukhin, A.M.; Gervash, A.A.; Safronov, V.M.

    2015-01-01

    Highlights: • We study the erosion, mass loss/gain and surface structure evolution of Be/CuCrZr mock-ups, armored with beryllium of TGP-56FW grade after irradiation by deuterium plasma heat load of 0.5 MJ/m 2 at 250 °C and 500 °C. • Beryllium mass loss/erosion under plasma heat load at 250 °C is rather small (no more than 0.2 g/m 2 shot and 0.11 μm/shot, correspondingly, after 40 shots) and tends to decrease with increasing number of shots. • Beryllium mass loss/erosion under plasma heat load at 500 °C is much higher (∼2.3 g/m 2 shot and 1.2 μm/shot, correspondingly, after 10 shot) and tends to decrease with increasing the number of shots (∼0.26 g/m 2 pulse and 0.14 μm/shot, correspondingly, after 100 shot). • Beryllium erosion value derived from the measurements of profile of irradiated surface is much higher than erosion value derived from mass loss data. - Abstract: Beryllium will be used as a armor material for the ITER first wall. It is expected that erosion of beryllium under transient plasma loads such as the edge-localized modes (ELMs) and disruptions will mainly determine a lifetime of the ITER first wall. This paper presents the results of recent experiments with the Russian beryllium of TGP-56FW ITER grade on QSPA-Be plasma gun facility. The Be/CuCrZr mock-ups were exposed to up to 100 shots by deuterium plasma streams (5 cm in diameter) with pulse duration of 0.5 ms and heat loads range of 0.2–0.5 MJ/m 2 at different temperature of beryllium tiles. The temperature of Be tiles has been maintained about 250 and 500 °C during the experiments. After 10, 40 and 100 shots, the beryllium mass loss/gain under erosion process were investigated as well as evolution of surface microstructure and cracks morphology

  16. Erosion of beryllium under ITER – Relevant transient plasma loads

    Energy Technology Data Exchange (ETDEWEB)

    Kupriyanov, I.B., E-mail: igkupr@gmail.com [A.A. Bochvar High Technology Research Institute of Inorganic Materials, Rogova St. 5a, 123060 Moscow (Russian Federation); Nikolaev, G.N.; Kurbatova, L.A.; Porezanov, N.P. [A.A. Bochvar High Technology Research Institute of Inorganic Materials, Rogova St. 5a, 123060 Moscow (Russian Federation); Podkovyrov, V.L.; Muzichenko, A.D.; Zhitlukhin, A.M. [TRINITI, Troitsk, Moscow reg. (Russian Federation); Gervash, A.A. [Efremov Research Institute, S-Peterburg (Russian Federation); Safronov, V.M. [Project Center of ITER, Moscow (Russian Federation)

    2015-08-15

    Highlights: • We study the erosion, mass loss/gain and surface structure evolution of Be/CuCrZr mock-ups, armored with beryllium of TGP-56FW grade after irradiation by deuterium plasma heat load of 0.5 MJ/m{sup 2} at 250 °C and 500 °C. • Beryllium mass loss/erosion under plasma heat load at 250 °C is rather small (no more than 0.2 g/m{sup 2} shot and 0.11 μm/shot, correspondingly, after 40 shots) and tends to decrease with increasing number of shots. • Beryllium mass loss/erosion under plasma heat load at 500 °C is much higher (∼2.3 g/m{sup 2} shot and 1.2 μm/shot, correspondingly, after 10 shot) and tends to decrease with increasing the number of shots (∼0.26 g/m{sup 2} pulse and 0.14 μm/shot, correspondingly, after 100 shot). • Beryllium erosion value derived from the measurements of profile of irradiated surface is much higher than erosion value derived from mass loss data. - Abstract: Beryllium will be used as a armor material for the ITER first wall. It is expected that erosion of beryllium under transient plasma loads such as the edge-localized modes (ELMs) and disruptions will mainly determine a lifetime of the ITER first wall. This paper presents the results of recent experiments with the Russian beryllium of TGP-56FW ITER grade on QSPA-Be plasma gun facility. The Be/CuCrZr mock-ups were exposed to up to 100 shots by deuterium plasma streams (5 cm in diameter) with pulse duration of 0.5 ms and heat loads range of 0.2–0.5 MJ/m{sup 2} at different temperature of beryllium tiles. The temperature of Be tiles has been maintained about 250 and 500 °C during the experiments. After 10, 40 and 100 shots, the beryllium mass loss/gain under erosion process were investigated as well as evolution of surface microstructure and cracks morphology.

  17. Investigation of Multi-Functional Ferroelectric Nanorod/Carbon Nanotube/Polymer Composites and Shape Memory Alloy Treatment for Vibration Control of Fire Control System to Improve Firing Accuracy

    Science.gov (United States)

    2015-08-10

    through the change in voltage. We also had to evaluate some of its material properties to insure that it had damping qualities as well as stability...was calculated. This ratio can be related to the logarithmic decrement of consecutive maxima of end displacements and can be correlated to how much...of force was achieved. The system was then set to instantaneously reduce load to 0 lbs. This procedure was repeated multiple times to determine

  18. Bounding estimate of DWPF mercury emissions

    International Nuclear Information System (INIS)

    Jacobs, R.A.

    1993-01-01

    Two factors which have substantial impact on predicted Mercury emissions are the air flows in the Chemical Process Cell (CPC) and the exit temperature of the Formic Acid Vent Condenser (FAVC). The discovery in the IDMS (Integrated DWPF Melter System) of H 2 generation by noble metal catalyzed formic acid decomposition and the resultant required dilution air flow has increased the expected instantaneous CPC air flow by as much as a factor of four. In addition, IDMS has experienced higher than design (10 degrees C) FAVC exit temperatures during certain portions of the operating cycle. These temperatures were subsequently attributed to the exothermic reaction of NO to NO 2 . Moreover, evaluation of the DWPF FAVC indicated it was undersized and unless modified or replaced, routine exit temperatures would be in excess of design. Purges required for H 2 flammability control and verification of elevated FAVC exit temperatures due to NO x reactions have lead to significant changes in CPC operating conditions. Accordingly, mercury emissions estimates have been updated based upon the new operating requirements, IDMS experience, and development of an NO x /FAVC model which predicts FAVC exit temperatures. Using very conservative assumptions and maximum purge rates, the maximum calculated Hg emissions is approximately 130 lbs/yr. A range of 100 to 120 lbs/yr is conservatively predicted for other operating conditions. The peak emission rate calculated is 0.027 lbs/hr. The estimated DWPF Hg emissions for the construction permit are 175 lbs/yr (0.02 lbs/hr annual average)

  19. Wear behavior of A356/M{sub 7}C{sub 3} and A356/SiC particulate metal matrix composites

    Energy Technology Data Exchange (ETDEWEB)

    Turhan, H. [Univ. of Firat, Dept. of Metallurgy, Elazig (Turkey); Yilmaz, O. [Univ. of Firat, Dept. of Metallurgical Engineering, Elazig (Turkey)

    2002-06-01

    The stability of M{sub 7}C{sub 3} carbides as reinforcement for A356 materials for tribological applications has been investigated. For this purpose, A356/M{sub 7}C{sub 3}, A356/SiC and A356/M{sub 7}C{sub 3}/SiC composites were prepared by powder metallurgy and tested at room temperature against SAE 4620 steel ring and AISI 304 stainless steel counterfaces under loads of 10 - 150 N. For comparison, also unreinforced A356 specimens were processed and tested under the same conditions. The tribological behavior was evaluated by microstructural examination of the wear-effected zones and by weight loss measurements of the specimens and counterfaces. The wear behavior of A356/M{sub 7}C{sub 3} composite gave an excellent result as function of the applied load because the M{sub 7}C{sub 3} particles act as load-bearing elements due to their excellent bonding to the Al matrix, and their interfaces withtood the wear stresses even at the highest applied load. Moreover, the M{sub 7}C{sub 3} particles limited the incorporation of wear debris into the Al matrix and reduced the wear damage occasioned to the steel counterfaces compared to that of A356 Al alloy. (orig.)

  20. Which adherence measure - self-report, clinician recorded or pharmacy refill - is best able to predict detectable viral load in a public ART programme without routine plasma viral load monitoring?

    Science.gov (United States)

    Mekuria, Legese A; Prins, Jan M; Yalew, Alemayehu W; Sprangers, Mirjam A G; Nieuwkerk, Pythia T

    2016-07-01

    Combination antiretroviral therapy (cART) suppresses viral replication to an undetectable level if a sufficiently high level of adherence is achieved. We investigated which adherence measurement best distinguishes between patients with and without detectable viral load in a public ART programme without routine plasma viral load monitoring. We randomly selected 870 patients who started cART between May 2009 and April 2012 in 10 healthcare facilities in Addis Ababa, Ethiopia. Six hundred and sixty-four (76.3%) patients who were retained in HIV care and were receiving cART for at least 6 months were included and 642 had their plasma HIV-1 RNA concentration measured. Patients' adherence to cART was assessed according to self-report, clinician recorded and pharmacy refill measures. Multivariate logistic regression model was fitted to identify the predictors of detectable viremia. Model accuracy was evaluated by computing the area under the receiver operating characteristic (ROC) curve. A total of 9.2% and 5.5% of the 642 patients had a detectable viral load of ≥40 and ≥400 RNA copies/ml, respectively. In the multivariate analyses, younger age, lower CD4 cell count at cART initiation, being illiterate and widowed, and each of the adherence measures were significantly and independently predictive of having ≥400 RNA copies/ml. The ROC curve showed that these variables altogether had a likelihood of more than 80% to distinguish patients with a plasma viral load of ≥400 RNA copies/ml from those without. Adherence to cART was remarkably high. Self-report, clinician recorded and pharmacy refill non-adherence were all significantly predictive of detectable viremia. The choice for one of these methods to detect non-adherence and predict a detectable viral load can therefore be based on what is most practical in a particular setting. © 2016 John Wiley & Sons Ltd.

  1. Characteristic study of high-Tc superconducting maglev under side-loading

    International Nuclear Information System (INIS)

    Wang Wei; Wang Jiasu; Liu Wei; Zheng Jun; Lin Qunxu; Pan Siting; Deng Zigang; Ma Guangtong; Wang Suyu

    2009-01-01

    In practical application of High-T c Superconducting (HTS) maglev, slant is an observable defect. It was caused by constantly one side on and off the vehicle by passengers. So far, this phenomenon has not been reported yet. In order to understand its influence on the stability of the HTS maglev, we experimentally studied the dynamic characteristic and slant effect of HTS maglev under center-load and side-load. It was found that load destabilizes the vehicle, and the side-load can obviously slant the vehicle body. In the end, the pre-load method was proposed to enhance the dynamic stability and suppress the slant, which proved to be considerably effective. These results are critical in practical running of HTS maglev

  2. Dual stimuli-sensitive dendrimers: Photothermogenic gold nanoparticle-loaded thermo-responsive elastin-mimetic dendrimers.

    Science.gov (United States)

    Fukushima, Daichi; Sk, Ugir Hossain; Sakamoto, Yasuhiro; Nakase, Ikuhiko; Kojima, Chie

    2015-08-01

    Dendrimers are synthetic macromolecules with unique structures that can work as nanoplatforms for both photothermogenic gold nanoparticles (AuNPs) and thermosensitive elastin-like peptides (ELPs) with valine-proline-glycine-valine-glycine (VPGVG) repeats. In this study, photothermogenic AuNPs were loaded into thermo-responsive elastin-mimetic dendrimers (dendrimers conjugating ELPs at their periphery) to produce dual stimuli-sensitive nanoparticles. Polyamidoamine G4 dendrimers were modified with acetylated VPGVG and (VPGVG)2, and the resulting materials were named ELP1-den and ELP2-den, respectively. The AuNPs were prepared by the reduction of Au ions using a dendrimer-nanotemplated method. The AuNP-loaded elastin-mimetic dendrimers exhibited photothermal properties. ELP1-den and ELP2-den showed similar temperature-dependent changes in their conformations. Phase transitions were observed at around 55°C and 35°C for the AuNP-loaded ELP1-den and AuNP-loaded ELP2-den, respectively, but not for the corresponding PEGylated dendrimer. In contrast to the AuNP-loaded PEGylated dendrimer, AuNP-loaded ELP2-den readily associated with cells and induced efficient photocytotoxicity at 37°C. The cell association and the photocytotoxicity properties of AuNP-loaded ELP2-den could be controlled by temperature. These results therefore suggest that dual stimuli-sensitive dendrimer nanoparticles of this type could be used for photothermal therapy. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Enhanced Cytotoxicity of Folic Acid-Targeted Liposomes Co-Loaded with C6 Ceramide and Doxorubicin: In Vitro Evaluation on HeLa, A2780-ADR, and H69-AR Cells.

    Science.gov (United States)

    Sriraman, Shravan Kumar; Pan, Jiayi; Sarisozen, Can; Luther, Ed; Torchilin, Vladimir

    2016-02-01

    Current research in cancer therapy is beginning to shift toward the use of combinational drug treatment regimens. However, the efficient delivery of drug combinations is governed by a number of complex factors in the clinical setting. Therefore, the ability to synchronize the pharmacokinetics of the individual therapeutic agents present in combination not only to allow for simultaneous tumor accumulation but also to allow for a synergistic relationship at the intracellular level could prove to be advantageous. In this work, we report the development of a novel folic acid-targeted liposomal formulation simultaneously co-loaded with C6 ceramide and doxorubicin [FA-(C6+Dox)-LP]. In vitro cytotoxicity assays showed that the FA-(C6+Dox)-LP was able to significantly reduce the IC50 of Dox when compared to that after the treatment with the doxorubicin-loaded liposomes (Dox-LP) as well as the untargeted drug co-loaded (C6+Dox)-LP on HeLa, A2780-ADR, and H69-AR cells. The analysis of the cell cycle distribution showed that while the C6 liposomes (C6-LP) did not cause cell cycle arrest, all the Dox-containing liposomes mediated cell cycle arrest in HeLa cells in the G2 phase at Dox concentrations of 0.3 and 1 μM and in the S phase at the higher concentrations. It was also found that this arrest in the S phase precedes the progression of the cells to apoptosis. The targeted FA-(C6+Dox)-LP were able to significantly enhance the induction of apoptotic events in HeLa cell monolayers as compared to the other treatment groups. Next, using time-lapse phase holographic imaging microscopy, it was found that upon treatment with the FA-(C6+Dox)-LP, the HeLa cells underwent rapid progression to apoptosis after 21 h as evidenced by a drastic drop in the average area of the cells after loss of cell membrane integrity. Finally, upon evaluation in a HeLa spheroid cell model, treatment with the FA-(C6+Dox)-LP showed significantly higher levels of cell death compared to those with C6-LP and

  4. Distribution load forecast with interactive correction of horizon loads

    International Nuclear Information System (INIS)

    Glamochanin, V.; Andonov, D.; Gagovski, I.

    1994-01-01

    This paper presents the interactive distribution load forecast application that performs the distribution load forecast with interactive correction of horizon loads. It consists of two major parts implemented in Fortran and Visual Basic. The Fortran part is used for the forecasts computations. It consists of two methods: Load Transfer Coupling Curve Fitting (LTCCF) and load Forecast Using Curve Shape Clustering (FUCSC). LTCCF is used to 'correct' the contaminated data because of load transfer among neighboring distribution areas. FUCSC uses curve shape clustering to forecast the distribution loads of small areas. The forecast for each small area is achieved by using the shape of corresponding cluster curve. The comparison of forecasted loads of the area with historical data will be used as a tool for the correction of the estimated horizon load. The Visual Basic part is used to provide flexible interactive user-friendly environment. (author). 5 refs., 3 figs

  5. Dicty_cDB: Contig-U16336-1 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available 90 |pid:none) Thulinius stephaniae clone Thul63f... 42 0.16 CP001325_660( CP00132.... 44 0.055 AF486293_1( AF486293 |pid:none) Giardia intestinalis alpha adaptin... 43 0.072 EU020990_1( EU0209

  6. EXPERIMENTAL EVALUATION OF THE FULLY LOADED ELK RIVER REACTOR

    Energy Technology Data Exchange (ETDEWEB)

    Fisher, J. R.; Diaz, A.

    1963-06-15

    The loading and testing program of the Elk River Reactor confirmed the predicted values. The measured cold, clean excess reactivity agrees to 2% and the control rod worths to 1% of the calculated values. The reactivity for various core loadings and rod positions is tabulated. The effects of spiked elements on the reactivity and radial peak-toaverage power ratio were studied. (D.L.C.)

  7. Appropriate heat load ratio of generator for different types of air cooled lithium bromide–water double effect absorption chiller

    International Nuclear Information System (INIS)

    Li, Zeyu; Liu, Jinping

    2015-01-01

    temperature of high pressure generator as well as surrounding temperature and it goes down with the rise of evaporator temperature and effectiveness of high temperature heat exchanger. The dependence of minimum heat load ratio of generator for the series and rear parallel flow system on the effectiveness of low temperature heat exchanger is weak. While the minimum heat load ratio of generator of pre-parallel and reverse parallel flow chiller rises with the increase of effectiveness of low temperature heat exchanger. The minimum heat load ratio of generator of reverse parallel flow configuration is independent upon the distribution ratio. The minimum heat load ratio of generator of pre-parallel flow system goes up fast with the rise of distribution ratio when the distribution ratio exceeds to 0.55. But the minimum heat load ratio of generator of rear parallel flow configuration just rises slightly with the increase of distribution ratio as the distribution is greater than 0.5. The paper is helpful to the development and performance improvement of air cooled lithium bromide–water double effect absorption chiller

  8. Effect of fiber coating on interfacial shear strength of SiC/SiC by nano-indentation technique

    International Nuclear Information System (INIS)

    Hinoki, T.; Zhang, W.; Kohyama, A.; Noda, T.

    1998-01-01

    In order to quantitatively evaluate mechanical properties of fibers, matrices and their interfaces in fiber reinforced SiC/SiC composites, fiber push-out tests have been carried out. From the indentation load vs. displacement relations, the fiber push-out process has been discussed in comparison with the C/C composites and the loads for fiber push-in and those for fiber push-out were estimated. The trends of load-displacement curve of fiber push-out process depended on specimen thickness. The curve in the case of thick specimen had a micro step indicating fiber push-in and a larger step corresponding to fiber push-out. However just a larger step indicating fiber push-out was seen without fiber push-in process in the case of thin specimen. Interfacial shear stress was discussed and defined in both cases. The effects of fiber coatings on interfacial shear stress obtained from thin specimens were analyzed. The relationship between bending stress and interfacial shear stress of SiC (pcs) /SiC (CVI) is preliminarily postulated together with microstructural characteristics of the composites. (orig.)

  9. Dynamic strength of rock with single planar joint under various loading rates at various angles of loads applied

    Directory of Open Access Journals (Sweden)

    Pei-Yun Shu

    2018-06-01

    Full Text Available Intact rock-like specimens and specimens that include a single, smooth planar joint at various angles are prepared for split Hopkinson pressure bar (SHPB testing. A buffer pad between the striker bar and the incident bar of an SHPB apparatus is used to absorb some of the shock energy. This can generate loading rates of 20.2–4627.3 GPa/s, enabling dynamic peak stresses/strengths and associated failure patterns of the specimens to be investigated. The effects of the loading rate and angle of load applied on the dynamic peak stresses/strengths of the specimens are examined. Relevant experimental results demonstrate that the failure pattern of each specimen can be classified as four types: Type A, integrated with or without tiny flake-off; Type B, slide failure; Type C, fracture failure; and Type D, crushing failure. The dynamic peak stresses/strengths of the specimens that have similar failure patterns increase linearly with the loading rate, yielding high correlations that are evident on semi-logarithmic plots. The slope of the failure envelope is the smallest for slide failure, followed by crushing failure, and that of fracture failure is the largest. The magnitude of the plot slope of the dynamic peak stress against the loading rate for the specimens that are still integrated after testing is between that of slide failure and crushing failure. The angle of application has a limited effect on the dynamic peak stresses/strengths of the specimens regardless of the failure pattern, but it affects the bounds of the loading rates that yield each failure pattern, and thus influences the dynamic responses of the single jointed specimen. Slide failure occurs at the lowest loading rate of any failure, but can only occur in single jointed specimen that allows sliding. Crushing failure is typically associated with the largest loading rate, and fracture failure may occur when the loading rate is between the boundaries for slide failure and crushing

  10. Field-induced magnetic phases in the normal and superconducting states of ErNi2B2C

    DEFF Research Database (Denmark)

    Jensen, A.; Toft, K.N.; Abrahamsen, A.B.

    2004-01-01

    We present a comprehensive neutron-diffraction study of the magnetic structures of ErNi2B2C in the presence of a magnetic field applied along [010], [110], or [001]. In zero field, the antiferromagnetic structure is transversely polarized with Qapproximate to0.55a* and the moments along the b...

  11. NO{sub 2} gas sensing of flame-made Pt-loaded WO{sub 3} thick films

    Energy Technology Data Exchange (ETDEWEB)

    Samerjai, Thanittha [Nanoscience and Nanotechnology Program, Faculty of Graduate School, Chiang Mai University, Chiang Mai 50200 (Thailand); Tamaekong, Nittaya [Program in Materials Science, Faculty of Science, Maejo University, Chiang Mai 50290 (Thailand); Liewhiran, Chaikarn [Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Wisitsoraat, Anurat [Nanoelectronics and MEMS Laboratory, National Electronics and Computer Technology Center, Klong Luang, Pathumthani 12120 (Thailand); Phanichphant, Sukon, E-mail: sphanichphant@yahoo.com [Materials Science Research Center, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand)

    2014-06-01

    Unloaded WO{sub 3} and 0.25–1.0 wt% Pt-loaded WO{sub 3} nanoparticles for NO{sub 2} gas detection were synthesized by flame spray pyrolysis (FSP) and characterized via X-ray diffraction (XRD), scanning electron microscopy (SEM) and high resolution transmission electron microscopy (HRTEM). The BET surface area (SSA{sub BET}) of the nanoparticles was measured by nitrogen adsorption. The NO{sub 2} sensing properties of the sensors based on unloaded and Pt-loaded WO{sub 3} nanoparticles were investigated. The results showed that the gas sensing properties of the Pt-loaded WO{sub 3} sensors were excellent to those of the unloaded one. Especially, 0.25 wt% Pt-loaded WO{sub 3} sensor showed highest response to NO{sub 2} than the others at low operating temperature of 150 °C. - Graphical abstract: The response of 0.25 wt% Pt-loaded WO3 sensor was 637 towards NO{sub 2} concentration of 10 ppm at 150 °C. - Highlights: • Unloaded and Pt-loaded WO{sub 3} nanoparticles for NO{sub 2} gas detection were synthesized by flame spray pyrolysis (FSP). • Gas sensing properties of the Pt-loaded WO{sub 3} sensors were excellent to those of the unloaded one. • 0.25 wt% Pt-loaded WO{sub 3} sensor showed highest response to NO{sub 2} at low operating temperature of 150 °C.

  12. In-situ Observation of Fracture Behavior on Nano Structure in NITE SiC/SiC Composite by HVEM

    International Nuclear Information System (INIS)

    Shibayama, Tamaki; Hamada, Kouichi; Watanabe, Seiichi; Matsuo, Genichiro; Kishimoto, Hirotatsu

    2011-01-01

    We have been successfully done in situ observation on the sequence of fracture event at the interface of NITE SiC/SiC composite examined by using miniaturized double notched shear specimen for TEM prepared by Focused Ion Beam method. In this study, we used nano-mechanics TEM experimental apparatus to investigate not only microstructure evolution and but also load and displacement curve at once in High Voltage Electron Microscope. Our results summarize as follows. Cracks were initiated at the interface between carbon coating layer on the SiC fiber and SiC matrices, and propagated along the interface. Load drop in the load and displacement curve during in-situ TEM was clearly observed at the crack initiation. The shear strength by using the miniaturized specimen is about ten times higher than that obtained by the standard testing.

  13. Exercise does not enhance aged bone's impaired response to artificial loading in C57Bl/6 mice.

    Science.gov (United States)

    Meakin, Lee B; Udeh, Chinedu; Galea, Gabriel L; Lanyon, Lance E; Price, Joanna S

    2015-12-01

    Bones adapt their structure to their loading environment and so ensure that they become, and are maintained, sufficiently strong to withstand the loads to which they are habituated. The effectiveness of this process declines with age and bones become fragile fracturing with less force. This effect in humans also occurs in mice which experience age-related bone loss and reduced adaptation to loading. Exercise engenders many systemic and local muscular physiological responses as well as engendering local bone strain. To investigate whether these physiological responses influence bones' adaptive responses to mechanical strain we examined whether a period of treadmill exercise influenced the adaptive response to an associated period of artificial loading in young adult (17-week) and old (19-month) mice. After treadmill acclimatization, mice were exercised for 30 min three times per week for two weeks. Three hours after each exercise period, right tibiae were subjected to 40 cycles of non-invasive axial loading engendering peak strain of 2250 με. In both young and aged mice exercise increased cross-sectional muscle area and serum sclerostin concentration. In young mice it also increased serum IGF1. Exercise did not affect bone's adaptation to loading in any measured parameter in young or aged bone. These data demonstrate that a level of exercise sufficient to cause systemic changes in serum, and adaptive changes in local musculature, has no effect on bone's response to loading 3h later. This study provides no support for the beneficial effects of exercise on bone in the elderly being mediated by systemic or local muscle-derived effects rather than local adaptation to altered mechanical strain. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  14. Experimental study of the aqueous CO2-NH3 rate of reaction for temperatures from 15 °C to 35 °C, NH3 concentrations from 5% to 15% and CO2 loadings from 0.2 to 0.6

    DEFF Research Database (Denmark)

    Lillia, Stefano; Bonalumi, Davide; Fosbøl, Philip L.

    2018-01-01

    , and lastly CO2 loadings from 0.2 to 0.6. The resulting overall mass transfer coefficient of absorption measured follows the trends described by the modelling of the reactor and the equations used to describe the rate of the absorption reactions. Moreover, the overall mass transfer coefficient of absorption...... loading conditions. The kinetic model intercept the values found in literature in every range of concentration. Consequently, the model is valid in every conditions and the rate of the reaction between NH3 and CO2 in liquid phase is described with an Arrhenius constant with a pre-exponential factor of 1......The absorption reaction between aqueous NH3 and CO2 was studied using the Wetted Wall Column. A total of 27 different cases are investigated in the region defined by temperatures from 15 °C to 35 °C, NH3 concentrations from 5% to 15%, which are the typical solvent conditions in absorption columns...

  15. InSitu SEM Investigation of Microstructural Damage Evolution and Strain Relaxation in a Melt Infiltrated SiC/SiC Composite

    Science.gov (United States)

    Sevener, Kathy; Chen, Zhe; Daly, Sam; Tracy, Jared; Kiser, Doug

    2016-01-01

    With CMC components poised to complete flight certification in turbine engines on commercial aircraft within the near future, there are many efforts within the aerospace community to model the mechanical and environmental degradation of CMCs. Direct observations of damage evolution are needed to support these modeling efforts and provide quantitative measures of damage parameters used in the various models. This study was performed to characterize the damage evolution during tensile loading of a melt infiltrated (MI) silicon carbide reinforced silicon carbide (SiC/SiC) composite. A SiC/SiC tensile coupon was loaded to a maximum global stress of 30 ksi in a tensile fixture within an SEM while observations were made at 5 ksi increments. Both traditional image analysis and DIC (digital image correlation) were used to quantify damage evolution. With the DIC analysis, microscale damage was observed at the fiber-matrix interfaces at stresses as low as 5 ksi. First matrix cracking took place between 20 and 25 ksi, accompanied by an observable relaxation in strain near matrix cracks. Matrix crack opening measurements at the maximum load ranged from 200 nm to 1.5 m. Crack opening along the fiber-matrix interface was also characterized as a function of load and angular position relative to the loading axis. This characterization was funded by NASA GRC and was performed to support NASA GRC modeling of SiC/SiC environmental degradation

  16. Plastic limit loads for cylindrical shell intersections under combined loading

    International Nuclear Information System (INIS)

    Skopinsky, V.N.; Berkov, N.A.; Vogov, R.A.

    2015-01-01

    In this research, applied methods of nonlinear analysis and results of determining the plastic limit loads for shell intersection configurations under combined internal pressure, in-plane moment and out-plane moment loadings are presented. The numerical analysis of shell intersections is performed using the finite element method, geometrically nonlinear shell theory in quadratic approximation and plasticity theory. For determining the load parameter of proportional combined loading, the developed maximum criterion of rate of change of relative plastic work is employed. The graphical results for model of cylindrical shell intersection under different two-parameter combined loadings (as generalized plastic limit load curves) and three-parameter combined loading (as generalized plastic limit load surface) are presented on the assumption that the internal pressure, in-plane moment and out-plane moment loads were applied in a proportional manner. - Highlights: • This paper presents nonlinear two-dimensional FE analysis for shell intersections. • Determining the plastic limit loads under combined loading is considered. • Developed maximum criterion of rate of change of relative plastic work is employed. • Plastic deformation mechanism in shell intersections is discussed. • Results for generalized plastic limit load curves of branch intersection are presented

  17. Thermal oxidation of cesium loaded Prussian blue as a precaution for exothermic phase change in extreme conditions

    International Nuclear Information System (INIS)

    Parajuli, Durga; Tanaka, Hisashi; Takahashi, Akira; Kawamoto, Tohru

    2013-01-01

    Cesium adsorbed Prussian blue is studied for the thermal oxidation. The TG-DTA shows exothermic phase change of micro aggregates of nano-PB at above 270°C. For this reason, Cs loaded PB was heated between 180 to 260°C. Heating at 180 removed only the water. Neither the oxidation of Iron nor the removal of cyanide is observed at this temperature. Oxidation of cyanide is observed upon heating above 200°C while loaded Cs is released after heating at >250°C followed by washing with water. Thermal oxidation between 200 to 220°C for more than 2 h showed control on exothermic phase change and loaded Cs is also not solubilized. (author)

  18. Optical triggering of 4H-SiC thyristors (18 kV class) to high currents in purely inductive load circuit

    International Nuclear Information System (INIS)

    Rumyantsev, S L; Levinshtein, M E; Saxena, T; Shur, M S; Cheng, L; Palmour, J W; Agarwal, A

    2014-01-01

    Optical switch-on of a very high voltage (18 kV class) 4H-SiC thyristor with an amplification step (pilot thyristor) to the current I max  = 1225 A is demonstrated using a purely inductive load and a calibrated air transformer. Increasing the inductance of the transformer primary winding slows down the turn on process. However, the inductance has little effect during the initial stage of the switch-on process when the voltage drop on the thyristor and its internal resistance is high. The results show that a further switch-on current increase can be only achieved by introducing additional amplification steps in the pilot thyristor. (paper)

  19. Sensorimotor modulation differs with load type during constant finger force or position.

    Directory of Open Access Journals (Sweden)

    Hikari Kirimoto

    Full Text Available During submaximal isometric contraction, there are two different load types: production of a constant force against a rigid restraint (force task, and maintenance of position against a constant load (position task. Previous studies reported that the time to task failure during a fatigue task was twice as long in the force task compared with the position task. Sensory feedback processing may contribute to these differences. The purpose of the current study was to determine the influence of load types during static muscle contraction tasks on the gating effect, i.e., attenuation of somatosensory-evoked potentials (SEPs and the cortical silent period (cSP. Ten healthy subjects contracted their right first dorsal interosseus muscle by abducting their index finger for 90 s, to produce a constant force against a rigid restraint that was 20% of the maximum voluntary contraction (force task, or to maintain a constant position with 10° abduction of the metacarpophalangeal joint against the same load (position task. Somatosensory evoked potentials (SEPs were recorded from C3' by stimulating either the right ulnar or median nerve at the wrist while maintaining contraction. The cortical silent period (cSP was also elicited by transcranial magnetic stimulation. Reduction of the amplitude of the P45 component of SEPs was significantly larger during the position task than during the force task and under control rest conditions when the ulnar nerve, but not the median nerve, was stimulated. The position task had a significantly shorter cSP duration than the force task. These results suggest the need for more proprioceptive information during the position task than the force task. The shorter duration of the cSP during the position task may be attributable to larger amplitude of heteronymous short latency reflexes. Sensorimotor modulations may differ with load type during constant finger force or position tasks.

  20. Hepatitis C

    Science.gov (United States)

    ... viral load (the amount of HCV in your blood), imaging tests, and biopsy results. Treatment is especially important for people who are showing signs liver fibrosis or scarring. Medicines used to treat hepatitis C ...

  1. [Determination of acidity and vitamin C in apples using portable NIR analyzer].

    Science.gov (United States)

    Yang, Fan; Li, Ya-Ting; Gu, Xuan; Ma, Jiang; Fan, Xing; Wang, Xiao-Xuan; Zhang, Zhuo-Yong

    2011-09-01

    Near infrared (NIR) spectroscopy technology based on a portable NIR analyzer, combined with kernel Isomap algorithm and generalized regression neural network (GRNN) has been applied to establishing quantitative models for prediction of acidity and vitamin C in six kinds of apple samples. The obtained results demonstrated that the fitting and the predictive accuracy of the models with kernel Isomap algorithm were satisfactory. The correlation between actual and predicted values of calibration samples (R(c)) obtained by the acidity model was 0.999 4, and for prediction samples (R(p)) was 0.979 9. The root mean square error of prediction set (RMSEP) was 0.055 8. For the vitamin C model, R(c) was 0.989 1, R(p) was 0.927 2, and RMSEP was 4.043 1. Results proved that the portable NIR analyzer can be a feasible tool for the determination of acidity and vitamin C in apples.

  2. Critical end point of the first-order ferromagnetic transition in a Sm{sub 0.55}(Sr{sub 0.5}Ca{sub 0.5}){sub 0.45}MnO{sub 3} single crystal

    Energy Technology Data Exchange (ETDEWEB)

    Radheep, D. Mohan [Centre for High Pressure Research, School of Physics, Bharathidasan University, Tiruchirappalli 620 024 (India); Sarkar, P. [Department of Physics, Serampore College, Serampore 712 201 (India); Arumugam, S. [Centre for High Pressure Research, School of Physics, Bharathidasan University, Tiruchirappalli 620 024 (India); Suryanarayanan, R. [Laboratoire de Physico-Chimie de l' Etat Solide, ICMMO, CNRS, UMR8182, Universite Paris-Sud, 91405 Orsay (France); Mandal, P., E-mail: prabhat.mandal@saha.ac.in [Saha Institute of Nuclear Physics, 1/AF Bidhannagar, Calcutta 700 064 (India)

    2014-09-01

    We report on the magnetic field (H) and hydrostatic pressure (P) dependence of the order of the ferromagnetic (FM) to paramagnetic phase transition in a Sm{sub 0.55}(Sr{sub 0.5}Ca{sub 0.5}){sub 0.45}MnO{sub 3} single crystal. At ambient condition, the system exhibits a first-order FM transition at T{sub C}≈82K (in heating cycle) with strong thermal hysteresis (∼13 K). The application of external H and P increases T{sub C}, suppresses the hysteresis width, and thus weakens the first-order nature of the transition. Our analysis reveals that the hysteresis vanishes and the first-order FM transition becomes a crossover above a critical magnetic field H{sub cr}≈11.5T. The value of H{sub cr} is highest among the manganite family, although the first-order nature of the FM transition is believed to be strongest in Eu{sub 1−x}Sr{sub x}MnO{sub 3}(x≈0.45). - Highlights: • System shows a strong first-order ferromagnetic to paramagnetic phase transition. • Extremely sharp metal–insulator transition at around 82 K. • The value of critical magnetic field at which first-order transition becomes a crossover is highest among manganites. • The nature of transition is sensitive to external perturbations such as magnetic field and pressure.

  3. The impacts of aerosol loading, composition, and water uptake on aerosol extinction variability in the Baltimore–Washington, D.C. region

    Directory of Open Access Journals (Sweden)

    A. J. Beyersdorf

    2016-01-01

    Full Text Available In order to utilize satellite-based aerosol measurements for the determination of air quality, the relationship between aerosol optical properties (wavelength-dependent, column-integrated extinction measured by satellites and mass measurements of aerosol loading (PM2.5 used for air quality monitoring must be understood. This connection varies with many factors including those specific to the aerosol type – such as composition, size, and hygroscopicity – and to the surrounding atmosphere, such as temperature, relative humidity (RH, and altitude, all of which can vary spatially and temporally. During the DISCOVER-AQ (Deriving Information on Surface conditions from Column and Vertically Resolved Observations Relevant to Air Quality project, extensive in situ atmospheric profiling in the Baltimore, MD–Washington, D.C. region was performed during 14 flights in July 2011. Identical flight plans and profile locations throughout the project provide meaningful statistics for determining the variability in and correlations between aerosol loading, composition, optical properties, and meteorological conditions. Measured water-soluble aerosol mass was composed primarily of ammonium sulfate (campaign average of 32 % and organics (57 %. A distinct difference in composition was observed, with high-loading days having a proportionally larger percentage of sulfate due to transport from the Ohio River Valley. This composition shift caused a change in the aerosol water-uptake potential (hygroscopicity such that higher relative contributions of inorganics increased the bulk aerosol hygroscopicity. These days also tended to have higher relative humidity, causing an increase in the water content of the aerosol. Conversely, low-aerosol-loading days had lower sulfate and higher black carbon contributions, causing lower single-scattering albedos (SSAs. The average black carbon concentrations were 240 ng m−3 in the lowest 1 km, decreasing to 35

  4. Opposite effects of capacity load and resolution load on distractor processing.

    Science.gov (United States)

    Zhang, Weiwei; Luck, Steven J

    2015-02-01

    According to the load theory of attention, an increased perceptual load reduces distractor processing whereas an increased working memory load facilitates distractor processing. Here we raise the possibility that the critical distinction may instead be between an emphasis on resolution and an emphasis on capacity. That is, perceptual load manipulations typically emphasize resolution (fine-grained discriminations), whereas working memory load manipulations typically emphasize capacity (simultaneous processing of multiple relevant stimuli). To test the plausibility of this hypothesis, we used a visual working memory task that emphasized either the number of items to be stored (capacity load, retaining 2 vs. 4 colors) or the precision of the representations (resolution load, detecting small vs. large color changes). We found that an increased capacity load led to increased flanker interference (a measure of distractor processing), whereas an increased resolution load led to reduced flanker interference. These opposite effects of capacity load and resolution load on distractor processing mirror the previously described opposite effects of perceptual load and working memory load.

  5. The Military Inventory Routing Problem with Direct Delivery

    Science.gov (United States)

    2014-03-27

    helicopters led to the use of “ Jingle Air”, a group of contractors that operate helicopters in support of resupply missions. During a deployment to...PMCS) between routes. This also roughly matches the average flight hours associated with a “ Jingle Air” mission of 6.4 hours [12]. In order to...an even multiple of the standard pallet weights used by the Army. Furthermore, the average load of a “ Jingle Air” helicopter is 4,000 lbs. [12

  6. Fracture toughness of the F-82H steel-effect of loading modes, hydrogen, and temperature

    International Nuclear Information System (INIS)

    Li, H.-X.; Jones, R.H.; Hirth, J.P.; Gelles, D.S.

    1996-01-01

    The effects of loading mode, hydrogen, and temperature on fracture toughness and tearing modulus were examined for a ferritic/martensitic steel (F-82H). The introduction of a shear load component, mode III, significantly decreased the initiation and propagation resistance of cracks compared to the opening load, mode I, behavior. Mode I crack initiation and propagation exhibited the highest resistance. A minimum resistance occurred when the mode I and mode III loads were nearly equal. The presence of 4 wppm hydrogen decreased the cracking resistance compared to behavior without H regardless of the loading mode. The minimum mixed-mode fracture toughness with the presence of hydrogen was about 30% of the hydrogen-free mode I fracture toughness. The mixed-mode toughness exhibited a lesser sensitivity to temperature than the mode I toughness. The J IC value was 284 kJ/m 2 at room temperature, but only 60 kJ/m 2 at -55 C and 30 kJ/m 2 at -90 C. The ductile to brittle transition temperature (DBTT) was apparently higher than -55 C. (orig.)

  7. Load testing circuit

    DEFF Research Database (Denmark)

    2009-01-01

    A load testing circuit a circuit tests the load impedance of a load connected to an amplifier. The load impedance includes a first terminal and a second terminal, the load testing circuit comprising a signal generator providing a test signal of a defined bandwidth to the first terminal of the load...

  8. Prices dip along with volume

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    The summer doldrums took hold in July, with only eight deals taking place, four on the spot concentrates market, two in conversion and two in enrichment. Spot concentrates volume dropped by 23% to nearly 1.2 million lbs U308 equivalent, resulting in slight declines in NUKEM's restricted and unrestricted price ranges. There were four deals on the spot market in July, totaling nearly 1.2 million lbs U3O8 equivalent. One of the buyers, a US utility, bought low-enriched uranium containing up to 440,000 lbs equivalent. Two of the buyers, a European and a US utility, purchased nearly 580,000 lbs of concentrates, with most going to the European utility. And another US utility bought UF6 containing 149,000 lbs equivalent. As for new demand, four buyers - including the European and US utilities that bought concentrates, as well as an East European utility and a non-US producer - entered the market during the month seeking 1.4 million lbs equivalent. The latter two buyers, along with another European utility and another US utility, are now weighing offers for more than 2.2 million lbs U3O8 equivalent. Looking ahead, we anticipate that as many as 17 buyers may enter the market for nearly 5 million lbs equivalent

  9. Promising biocidal activity of thymol loaded chitosan silver nanoparticles (T-C@AgNPs) as anti-infective agents against perilous pathogens.

    Science.gov (United States)

    Manukumar, H M; Umesha, S; Kumar, H N Naveen

    2017-09-01

    The advent of biodegradable polymer-encapsulated drug nanoparticles has made an exciting area of drug delivery research. The present study investigated novel and simple route for synthesis of thymol loaded chitosan silver nanoparticles (T-C@AgNPs) using chitosan and thymol as reducing, capping agent respectively to understand the therapeutic efficacy. The UV-vis spectroscopy, DLS, FT-IR, SEM, EDS, XRD used for characterization and radical scavenging activity, anti-microbial and biocompatibility was taken to ascertain an efficacy of novel T-C@AgNPs. The T-C@AgNPs intense peak at 490nm indicates the formation of nanoparticles and had average particle size of 28.94nm with spherical shape, monodisperse state in water, also exhibited excellent biocompatibility of cubic shaped pure silver element containing T-C@AgNPs. The antibacterial activity was studied for gram positive and gram negative food-borne pathogens and effective inhibition at 100μgmL -1 to S. aureus, S. epidermidis, S. haemolyticus (10.08, 10.00, 11.23mm) and S. typhimurium, P. aeruginosa and S. flexneri (9.28, 9.33, 12.03mm) compared to antibiotic Streptomycin. This study revealed the efficacy against multiple food-borne pathogens and therapeutic efficacy of T-C@AgNPs offers a valuable contribution in the area of nanotechnology. This proved to be a first-class novel antimicrobial material for the first time in this study. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Active load reduction using individual pitch, based on local blade flow measurements

    DEFF Research Database (Denmark)

    Larsen, Torben J.; Aagaard Madsen, H.; Thomsen, K.

    2005-01-01

    -of-the-art load-reducing concepts. Since the new flow-based concept deviates significantly from previous published load-reducing strategies, a comparison of the performance based on aeroelastic simulations is included. Advantages and drawbacks of the systems are discussed. Copyright (C) 2004 John Wiley Sons, Ltd.......A new load-reducing control strategy for individual blade control of large pitch-controlled wind turbines is presented This control concept is based on local blade inflow measurements and offers the possibility of larger load reductions, without loss of power production, than seen in other state...

  11. J-integral and limit load analysis of semi-elliptical surface cracks in plates under bending

    International Nuclear Information System (INIS)

    Lei, Y.

    2004-01-01

    Systematic detailed linear and non-linear finite element (FE) analyses are performed for semi-elliptical surface cracks in plates under bending. Limit load (moment) solutions are obtained from the FE J results via the reference stress method. The FE results show that the Newman and Raju stress intensity factor equation is reasonably accurate and the Yagawa et al. J solution may significantly under estimate J for bending load. The relationship between J and the limit load is found to be dependent on the ratio a/t and a/c, where a and c are the depth and the half-length of the crack and t is the plate thickness. For a/t≤0.5 with a/c=0.2, J for any position along a crack front can be predicted by the reference stress method using a single limit load value except for the points very close to the plate surface. For all other cases, it can only be approximately estimated by the reference stress method because a limit load value that can satisfy all the FE J solutions along the crack front cannot be found. However, for all the cases examined, the maximum J along the crack front can be well predicted by the reference stress method when a proper global limit load is used. The Goodall and Webster global limit load equation is extended to any crack depth. The limit load data obtained in this paper can be well reproduced by the extended equation

  12. The scaling of stress distribution under small scale yielding by T-scaling method and application to prediction of the temperature dependence on fracture toughness

    International Nuclear Information System (INIS)

    Ishihara, Kenichi; Hamada, Takeshi; Meshii, Toshiyuki

    2017-01-01

    In this paper, a new method for scaling the crack tip stress distribution under small scale yielding condition was proposed and named as T-scaling method. This method enables to identify the different stress distributions for materials with different tensile properties but identical load in terms of K or J. Then by assuming that the temperature dependence of a material is represented as the stress-strain relationship temperature dependence, a method to predict the fracture load at an arbitrary temperature from the already known fracture load at a reference temperature was proposed. This method combined the T-scaling method and the knowledge “fracture stress for slip induced cleavage fracture is temperature independent.” Once the fracture load is predicted, fracture toughness J c at the temperature under consideration can be evaluated by running elastic-plastic finite element analysis. Finally, the above-mentioned framework to predict the J c temperature dependency of a material in the ductile-to-brittle temperature distribution was validated for 0.55% carbon steel JIS S55C. The proposed framework seems to have a possibility to solve the problem the master curve is facing in the relatively higher temperature region, by requiring only tensile tests. (author)

  13. Review of ship slamming loads and responses

    Science.gov (United States)

    Wang, Shan; Guedes Soares, C.

    2017-12-01

    The paper presents an overview of studies of slamming on ship structures. This work focuses on the hull slamming, which is one of the most important types of slamming problems to be considered in the ship design process and the assessment of the ship safety. There are three main research aspects related to the hull slamming phenomenon, a) where and how often a slamming event occurs, b) slamming load prediction and c) structural response due to slamming loads. The approaches used in each aspect are reviewed and commented, together with the presentation of some typical results. The methodology, which combines the seakeeping analysis and slamming load prediction, is discussed for the global analysis of the hull slamming of a ship in waves. Some physical phenomena during the slamming event are discussed also. Recommendations for the future research and developments are made.

  14. 46 CFR 154.1730 - Ethylene oxide: Loading and off loading.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Ethylene oxide: Loading and off loading. 154.1730... Operating Requirements § 154.1730 Ethylene oxide: Loading and off loading. (a) The master shall ensure that before ethylene oxide is loaded into a cargo tank: (1) The tank is thoroughly clean, dry, and free of...

  15. Perceptual load corresponds with factors known to influence visual search.

    Science.gov (United States)

    Roper, Zachary J J; Cosman, Joshua D; Vecera, Shaun P

    2013-10-01

    One account of the early versus late selection debate in attention proposes that perceptual load determines the locus of selection. Attention selects stimuli at a late processing level under low-load conditions but selects stimuli at an early level under high-load conditions. Despite the successes of perceptual load theory, a noncircular definition of perceptual load remains elusive. We investigated the factors that influence perceptual load by using manipulations that have been studied extensively in visual search, namely target-distractor similarity and distractor-distractor similarity. Consistent with previous work, search was most efficient when targets and distractors were dissimilar and the displays contained homogeneous distractors; search became less efficient when target-distractor similarity increased irrespective of display heterogeneity. Importantly, we used these same stimuli in a typical perceptual load task that measured attentional spillover to a task-irrelevant flanker. We found a strong correspondence between search efficiency and perceptual load; stimuli that generated efficient searches produced flanker interference effects, suggesting that such displays involved low perceptual load. Flanker interference effects were reduced in displays that produced less efficient searches. Furthermore, our results demonstrate that search difficulty, as measured by search intercept, has little bearing on perceptual load. We conclude that rather than be arbitrarily defined, perceptual load might be defined by well-characterized, continuous factors that influence visual search. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  16. The brassinosteroid receptor BRI1 can generate cGMP enabling cGMP-dependent downstream signaling

    CSIR Research Space (South Africa)

    Wheeler, J

    2017-06-01

    Full Text Available ) with the ll PickUp Injection mode using the loading pump at 15 ll min�1 flow rate for 3 min. Samples were then loaded on a RSLC, 75 lm 9 500 mm, nanoVi- per, C18, 2 lm, 100 �A column (Acclaim, PepMap) retrofitted to an EASY-spray source with a flow rate of 300... receptor BRI1 can generate cGMP enabling cGMP-dependent downstream signaling Janet I. Wheeler1,2,†, Aloysius Wong3,4, Claudius Marondedze3,5, Arnoud J. Groen5, Lusisizwe Kwezi1,6, Lubna Freihat1, Jignesh Vyas1, Misjudeen A. Raji7, Helen R. Irving1...

  17. Automatic control of load increases power and efficiency in a microbial fuel cell

    Energy Technology Data Exchange (ETDEWEB)

    Premier, Giuliano C.; Kim, Jung Rae; Michie, Iain [Sustainable Environment Research Centre (SERC), Faculty of Advanced Technology, University of Glamorgan, Pontypridd, Mid-Glamorgan CF37 1DL (United Kingdom); Dinsdale, Richard M.; Guwy, Alan J. [Sustainable Environment Research Centre (SERC), Faculty of Health, Sport and Science, University of Glamorgan, Pontypridd, Mid-Glamorgan CF37 1DL (United Kingdom)

    2011-02-15

    Increasing power production and coulombic efficiency (CE) of microbial fuel cells (MFCs) is a common research ambition as the viability of the technology depends to some extent on these measures of performance. As MFCs are typically time varying systems, comparative studies of controlled and un-controlled external load impedance are needed to show if control affects the biocatalyst development and hence MFC performance. The application of logic based control of external load resistance is shown to increase the power generated by the MFC, when compared to an equivalent system which has a static resistive load. The controlled MFC generated 1600 {+-} 400 C, compared to 300 {+-} 10 C with an otherwise replicate fixed load MFC system. The use of a parsimonious gradient based control was able to increase the CE to within the range of 15.1-22.7%, while the CE for a 200 {omega} statically loaded MFC lay in the range 3.3-3.7%. The controlled MFC improves the electrogenic anodic biofilm selection for power production, indicating that greater power and substrate conversion can be achieved by controlling load impedance. Load control ensured sustainable current demand, applied microbial selection pressures and provided near-optimal impedance for power transference, compared to the un-controlled system. (author)

  18. Analysis of temperature changes on three-phase synchronous generator using infrared: comparison between balanced and unbalanced load

    Science.gov (United States)

    Amien, S.; Yoga, W.; Fahmi, F.

    2018-02-01

    Synchronous generators are a major tool in an electrical energy generating systems, the load supplied by the generator is unbalanced. This paper discusses the effect of synchronous generator temperature on the condition of balanced load and unbalanced load, which will then be compared with the measurement result of both states of the generator. Unbalanced loads can be caused by various asymmetric disturbances in the power system and the failure of load forecasting studies so that the load distribution in each phase is not the same and causing the excessive heat of the generator. The method used in data collection was by using an infrared thermometer and resistance calculation method. The temperature comparison result between the resistive, inductive and capacitive loads in the highest temperature balance occured when the generator is loaded with a resistive load, where T = 31.9 ° C and t = 65 minutes. While in a state of unbalanced load the highest temperature occured when the generator is loaded with a capacitive load, where T = 40.1 ° C and t = 60 minutes. By understanding this behavior, we can maintain the generator for longer operation life.

  19. Borax-Loaded PLLA for Promotion of Myogenic Differentiation.

    Science.gov (United States)

    Rico, Patricia; Rodrigo-Navarro, Aleixandre; Salmerón-Sánchez, Manuel

    2015-11-01

    Boron is an essential metalloid, which plays a key role in plant and animal metabolisms. It has been reported that boron is involved in bone mineralization, has some uses in synthetic chemistry, and its potential has been only recently exploited in medicinal chemistry. However, in the area of tissue engineering, the use of boron is limited to works involving certain bioactive glasses. In this study, we engineer poly(l-lactic acid) (PLLA) substrates with sustained release of boron. Then, we analyze for the first time the uniqueness effects of boron in cell differentiation using murine C2C12 myoblasts and discuss a potential mechanism of action in cooperation with Ca(2+). Our results demonstrate that borax-loaded materials strongly enhance myotube formation at initial steps of myogenesis. Furthermore, we demonstrate that Ca(2+) plays an essential role in combination with borax as chelating or blocking Ca(2+) entry into the cell leads to a detrimental effect on myoblast differentiation observed on borax-loaded materials. This research identifies borax-loaded materials to trigger differentiation mechanisms and it establishes a new tool to engineer microenvironments with applications in regenerative medicine for muscular diseases.

  20. Peak load-impulse characterization of critical pulse loads in structural dynamics

    International Nuclear Information System (INIS)

    Abrahamson, G.R.; Lindberg, H.E.

    1975-01-01

    In presenting the characterization scheme, some general features are described first. A detailed analysis is given for the rigid-plastic system of one degree of freedom to illustrate the calculation of critical load curves in terms of peak load and impulse. This is followed by the presentation of critical load curves for uniformly loaded rigid-plastic beams and plates and for dynamic buckling of cylindrical shells under uniform lateral loads. The peak load-impulse characterization of critical pulse loads is compared with the dynamic load factor characterization, and some aspects of the history of the peak load-pulse scheme are presented. (orig./HP) [de

  1. Zein nanoparticle as a novel BMP6 derived peptide carrier for enhanced osteogenic differentiation of C2C12 cells.

    Science.gov (United States)

    Hadavi, Mahvash; Hasannia, Sadegh; Faghihi, Shahab; Mashayekhi, Farhad; Homazadeh, Homayoun; Mostofi, Seyed Behrooz

    2018-01-26

    Zein nanoparticles as a carrier system for BMP6-derived peptide were prepared by liquid-liquid phase separation procedure and characterized with SEM, DLS, FTIR and thermogravimetric methods. After peptide encapsulation, nanoparticle size increased from 236.3 ± 92.2 nm to 379.4 ± 116.8 nm. The encapsulation efficiency of peptide was 72.6% and the release of peptide from Zein nanoparticles was partly sustained in trypsin containing phosphate buffered saline (pH 7.4) for up to 14 days. Peptide-loaded nanoparticles showed similar cell viability compared with blank ones. ALP activity of C2C12 cells treated with peptide-loaded nanoparticles (500 µg/mL) was evaluated 7, 14, 21 and 28 days after culture. In peptide-loaded nanoparticles, ALP activity was significantly higher (p < .05) compared with other groups at day 14. Alizarin Red S staining showed, C2C12 cells behind peptide-loaded nanoparticles had significantly (p < .05) higher calcium deposition at day 21. The results of RT-qPCR show that the BMP-6 peptide activated expression of RUNX2 as a transcription factor. In turn, RUNX2 regulates SPP1 and BGLAP gene expression, as osteogenic marker genes. The results confirm that the peptide-loaded Zein nanoparticles, as osteoinductive material, may be used to repair small area of bone defects, with low load bearing.

  2. Remarkably enhanced photocatalytic hydrogen evolution over MoS2 nanosheets loaded on uniform CdS nanospheres

    Science.gov (United States)

    Chai, Bo; Xu, Mengqiu; Yan, Juntao; Ren, Zhandong

    2018-02-01

    The MoS2/CdS composites with layered MoS2 loaded on uniform CdS nanospheres were synthesized by a two-step process combination hydrothermal and solvothermal treatments, and then applied in photocatalytic hydrogen evolution under visible light irradiation. The as-prepared samples were characterized by X-ray diffraction (XRD), field emission scanning electron microscopy (FESEM), energy dispersive X-ray spectrometer (EDS), high-resolution transmission electron microscopy (HRTEM), X-ray photoelectron spectroscopy (XPS), Raman spectra, UV-vis diffuse reflectance absorption spectra (UV-DRS), nitrogen adsorption-desorption measurement, photoluminescence spectra (PL) and photoelectrochemical tests. The effects of loading contents of MoS2 in the composites on the photocatalytic H2 evolution activity were comparatively investigated with 0.45 mol L-1 Na2S and 0.55 mol L-1 Na2SO3 as sacrificial agents. The results showed that the 5 wt% MoS2/CdS composite could achieve the highest photocatalytic H2 evolution rate of 372 μmol h-1 and apparent quantum efficiency (AQE) about 7.31% under 420 nm monochromatic light irradiation. The remarkably enhanced photocatalytic activity of MoS2/CdS composite could be attributed to the effective transfer and separation of photogenerated charge carriers, and MoS2 being as a cocatalyst to facilitating photocatalytic H2 evolution reaction. A tentative mechanism of MoS2/CdS composites as photocatalysts for H2 evolution was proposed.

  3. Hydrophobic Drug-Loaded PEGylated Magnetic Liposomes for Drug-Controlled Release

    Science.gov (United States)

    Hardiansyah, Andri; Yang, Ming-Chien; Liu, Ting-Yu; Kuo, Chih-Yu; Huang, Li-Ying; Chan, Tzu-Yi

    2017-05-01

    Less targeted and limited solubility of hydrophobic-based drug are one of the serious obstacles in drug delivery system. Thus, new strategies to enhance the solubility of hydrophobic drug and controlled release behaviors would be developed. Herein, curcumin, a model of hydrophobic drug, has been loaded into PEGylated magnetic liposomes as a drug carrier platform for drug controlled release system. Inductive magnetic heating (hyperthermia)-stimulated drug release, in vitro cellular cytotoxicity assay of curcumin-loaded PEGylated magnetic liposomes and cellular internalization-induced by magnetic guidance would be investigated. The resultant of drug carriers could disperse homogeneously in aqueous solution, showing a superparamagnetic characteristic and could inductive magnetic heating with external high-frequency magnetic field (HFMF). In vitro curcumin release studies confirmed that the drug carriers exhibited no significant release at 37 °C, whereas exhibited rapid releasing at 45 °C. However, it would display enormous (three times higher) curcumin releasing under the HFMF exposure, compared with that without HFMF exposure at 45 °C. In vitro cytotoxicity test shows that curcumin-loaded PEGylated magnetic liposomes could efficiently kill MCF-7 cells in parallel with increasing curcumin concentration. Fluorescence microscopy observed that these drug carriers could internalize efficiently into the cellular compartment of MCF-7 cells. Thus, it would be anticipated that the novel hydrophobic drug-loaded PEGylated magnetic liposomes in combination with inductive magnetic heating are promising to apply in the combination of chemotherapy and thermotherapy for cancer therapy.

  4. Prolonged local persistence of cisplatin-loaded gelatin microspheres and their chemoembolic anti-cancer effect in rabbits

    International Nuclear Information System (INIS)

    Ohta, Shinichi; Nitta, Norihisa; Sonoda, Akinaga; Seko, Ayumi; Tanaka, Toyohiko; Takahashi, Masashi; Takemura, Shizuki; Tabata, Yasuhiko; Murata, Kiyoshi

    2009-01-01

    Purpose: To confirm prolonged cisplatin release from drug-loaded gelatin microspheres (GMSs) and their improved chemoembolic anti-cancer effect against VX2 liver tumors in rabbits. Materials and methods: Two groups of twelve rabbits each were treated intraarterially either with 2 mg/kg cisplatin-loaded GMSs (=0.04 mg/kg cisplatin) or 0.04 mg/kg cisplatin solution by administering them into the right renal artery. Platinum concentrations within the renal parenchyma were analyzed immediately following infusion (day 0) and on days 1, 3, and 7 using the atomic absorption method. In a second experiment four groups of five rabbits each with implanted VX2 liver tumors were treated intraarterially through the hepatic artery with the following drugs: 2 mg/kg cisplatin-loaded GMSs (=0.04 mg/kg cisplatin) (group I), 2 mg/kg GMSs without any drug (group II), 1.5 mg/kg cisplatin solution (group III) and saline (group IV). Tumor volumes were analyzed pre-injection and 7 days after with MRI allowing calculating the relative tumor growth rate (%). Degree of liver cell necrosis was assessed on the histopathological specimens. Results: The renal parenchymal platinum concentrations (μg/ml) with 4.51 ± 2.25 (day 0), 1.59 ± 0.70 (day 1), 0.72 ± 0.10 (day 3) and 0.20 ± 0.06 (day 7) were significantly more pronounced after cisplatin-loaded GMS on days one and three compared to cisplatin with 1.99 ± 0.55, 0.08 ± 0.03, 0.18 ± 0.01 and 0.10 ± 0.07, respectively. Relative tumor growth rates resulted in 84.5% ± 26.4 (group I); 241.4% ± 145.1 (II); 331.9% ± 72.2 (III), and 413.6% ± 103.6 (IV) with statistical significant differences between groups I and III, and groups I and IV. Similar degrees of necrosis were observed in both GMSs treated groups, while ballooning of hepatocytes was highest in cisplatin-loaded GMSs. Conclusions: With cisplatin-loaded GMSs more pronounced and prolonged local parenchymal cisplatin concentrations may be achieved offering the advantage of an

  5. Nafcillin-loaded PLGA nanoparticles for treatment of osteomyelitis

    International Nuclear Information System (INIS)

    Pillai, Rajeev Raghavan; Rabinovich, Monica; Gonsalves, Kenneth E; Somayaji, Shankari N; Hudson, Michael C

    2008-01-01

    The goal of this investigation is to develop poly(dl-lactide-co-glycolide) (PLGA) nanoparticles for the delivery of antibiotics such as nafcillin to osteoblasts. This is important in order to treat Staphylococcus aureus-mediated osteomyelitis. The latter is often chronic and highly resistant to antibiotics. Nafcillin (a penicillinase-resistant penicillin)-loaded nanoparticles were prepared by a single emulsion/solvent evaporation method. In vitro drug release studies were conducted in an incubator shaker at 37 deg. C in phosphate buffer saline. Drug loading and release were determined by UV-Vis spectroscopy. A viability study was conducted in S. aureus-infected mouse osteoblasts. In vitro release study showed an initial burst release and a second phase of slow release. Following 24 and 48 h of incubation, all formulations of nanoparticles loaded with nafcillin either killed or significantly reduced all of the intracellular bacteria. Our data demonstrate that effective killing of intracellular S. aureus is possible by treating the infected osteoblasts with nanoparticles loaded with nafcillin

  6. Nafcillin-loaded PLGA nanoparticles for treatment of osteomyelitis

    Energy Technology Data Exchange (ETDEWEB)

    Pillai, Rajeev Raghavan; Rabinovich, Monica; Gonsalves, Kenneth E [Polymer Nanotechnology Laboratory at Center for Optoelectronics and Department of Chemistry, University of North Carolina, Charlotte, NC 28223 (United States); Somayaji, Shankari N; Hudson, Michael C [Department of Biology, University of North Carolina, Charlotte, NC 28223 (United States)], E-mail: kegonsal@uncc.edu

    2008-09-01

    The goal of this investigation is to develop poly(dl-lactide-co-glycolide) (PLGA) nanoparticles for the delivery of antibiotics such as nafcillin to osteoblasts. This is important in order to treat Staphylococcus aureus-mediated osteomyelitis. The latter is often chronic and highly resistant to antibiotics. Nafcillin (a penicillinase-resistant penicillin)-loaded nanoparticles were prepared by a single emulsion/solvent evaporation method. In vitro drug release studies were conducted in an incubator shaker at 37 deg. C in phosphate buffer saline. Drug loading and release were determined by UV-Vis spectroscopy. A viability study was conducted in S. aureus-infected mouse osteoblasts. In vitro release study showed an initial burst release and a second phase of slow release. Following 24 and 48 h of incubation, all formulations of nanoparticles loaded with nafcillin either killed or significantly reduced all of the intracellular bacteria. Our data demonstrate that effective killing of intracellular S. aureus is possible by treating the infected osteoblasts with nanoparticles loaded with nafcillin.

  7. System and method employing a minimum distance and a load feature database to identify electric load types of different electric loads

    Science.gov (United States)

    Lu, Bin; Yang, Yi; Sharma, Santosh K; Zambare, Prachi; Madane, Mayura A

    2014-12-23

    A method identifies electric load types of a plurality of different electric loads. The method includes providing a load feature database of a plurality of different electric load types, each of the different electric load types including a first load feature vector having at least four different load features; sensing a voltage signal and a current signal for each of the different electric loads; determining a second load feature vector comprising at least four different load features from the sensed voltage signal and the sensed current signal for a corresponding one of the different electric loads; and identifying by a processor one of the different electric load types by determining a minimum distance of the second load feature vector to the first load feature vector of the different electric load types of the load feature database.

  8. Internal friction and mechanical properties of Zr - 2.5% Nb alloy after programme loading

    International Nuclear Information System (INIS)

    Gindin, I.A.; Chirkina, L.A.; Okovit, V.S.; Netesov, V.M.

    1984-01-01

    Temperature dependence of internal friction in the range 20-600 deg C of the alloy Zr-2.5% Nb in the initial state after programmed loading up to 0.1% of residual elongation and static deformation to the same deformation degree has been studied. It is shown, that the programmed loading promotes the decrease in relaxation rate at 20 and 200 deg C and the increase of strength characteristics of the alloy without the decrease in plasticity margin to fracture in the range 20-400 deg C

  9. System and method employing a self-organizing map load feature database to identify electric load types of different electric loads

    Science.gov (United States)

    Lu, Bin; Harley, Ronald G.; Du, Liang; Yang, Yi; Sharma, Santosh K.; Zambare, Prachi; Madane, Mayura A.

    2014-06-17

    A method identifies electric load types of a plurality of different electric loads. The method includes providing a self-organizing map load feature database of a plurality of different electric load types and a plurality of neurons, each of the load types corresponding to a number of the neurons; employing a weight vector for each of the neurons; sensing a voltage signal and a current signal for each of the loads; determining a load feature vector including at least four different load features from the sensed voltage signal and the sensed current signal for a corresponding one of the loads; and identifying by a processor one of the load types by relating the load feature vector to the neurons of the database by identifying the weight vector of one of the neurons corresponding to the one of the load types that is a minimal distance to the load feature vector.

  10. Spectroelectrochemical Study of Carbon Monoxide and Ethanol Oxidation on Pt/C, PtSn(3:1/C and PtSn(1:1/C Catalysts

    Directory of Open Access Journals (Sweden)

    Rubén Rizo

    2016-09-01

    Full Text Available PtSn-based catalysts are one of the most active materials toward that contribute ethanol oxidation reaction (EOR. In order to gain a better understanding of the Sn influence on the carbon monoxide (principal catalyst poison and ethanol oxidation reactions in acidic media, a systematic spectroelectrochemical study was carried out. With this end, carbon-supported PtSnx (x = 0, 1/3 and 1 materials were synthesized and employed as anodic catalysts for both reactions. In situ Fourier transform infrared spectroscopy (FTIRS and differential electrochemical mass spectrometry (DEMS indicate that Sn diminishes the amount of bridge bonded CO (COB and greatly improves the CO tolerance of Pt-based catalysts. Regarding the effect of Sn loading on the EOR, it enhances the catalytic activity and decreases the onset potential. FTIRS and DEMS analysis indicate that the C-C bond scission occurs at low overpotentials and at the same potential values regardless of the Sn loading, although the amount of C-C bond breaking decreases with the rise of Sn in the catalytic material. Therefore, the elevated catalytic activity toward the EOR at PtSn-based electrodes is mainly associated with the improved CO tolerance and the incomplete oxidation of ethanol to form acetic acid and acetaldehyde species, causing the formation of a higher amount of both C2 products with the rise of Sn loading.

  11. The privacy concerns in location based services: protection approaches and remaining challenges

    OpenAIRE

    Basiri, Anahid; Moore, Terry; Hill, Chris

    2016-01-01

    Despite the growth in the developments of the Location Based Services (LBS) applications, there are still several challenges remaining. One of the most important concerns about LBS, shared by many users and service providers is the privacy. Privacy has been considered as a big threat to the adoption of LBS among many users and consequently to the growth of LBS markets. This paper discusses the privacy concerns associated with location data, and the current privacy protection approaches. It re...

  12. A model for voltage collapse study considering load characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Aguiar, L B [Companhia de Energia Eletrica da Bahia (COELBA), Salvador, BA (Brazil)

    1994-12-31

    This paper presents a model for analysis of voltage collapse and instability problem considering the load characteristics. The model considers fundamentally the transmission lines represented by exact from through the generalized constants A, B, C, D and the loads as function of the voltage, emphasizing the cases of constant power, constant current and constant impedance. the study treats of the system behavior on steady state and presents illustrative graphics about the problem. (author) 12 refs., 4 figs.

  13. Demand Response Load Following of Source and Load Systems

    DEFF Research Database (Denmark)

    Hu, Jianqiang; Cao, Jinde; Yong, Taiyou

    2017-01-01

    This paper presents a demand response load following strategy for an interconnected source and load system, in which we utilize traditional units and population of cooling thermostatically controlled loads (TCLs) to follow the mismatched power caused by the load activities and the renewable power...... injection in real time. In the demand side of power systems, these TCLs are often affiliated to a bus load agent and can be aggregated to multiple TCL aggregators. Firstly, aggregate evaluation of the TCL aggregator is carried out based on a bilinear aggregate model so as to derive the available regulation...

  14. Development of unidirectional C/C composite with high thermal conductivity and its application to plasma facing materials

    International Nuclear Information System (INIS)

    Ioki, Kimihiro; Onozuka, Masanori; Ikeda, Takeshi; Akiba, Masato.

    1994-01-01

    Unidirectional C/C composite named 'MFC-1' with high conductivity was developed, and full-scale armor tiles were fabricated. The thermal conductivity in the direction perpendicular to the plasma-side surface is more than 300-500 W/m·degC, which is higher than those of other C/C composites ever made, even superior to that of pyrolytic carbon. It was shown by high heat load tests done using an electron beam test facility that the unidirectional C/C composite was very resistant against both surface erosion as well as severe thermal shock. The 'MFC-1' was successfully brazed to copper substrate, and its high thermal shock resistance was observed in heat load tests (20 MW/m 2 , 3s, not cooled). A functionally gradient material has been also developed as compliant layer for the MFC-1 bonded to copper. (author)

  15. 46 CFR 160.055-3 - Materials-standard life preservers.

    Science.gov (United States)

    2010-10-01

    ... chapter for Type A foam. (c) Envelope. The life preserver envelope, or cover, shall be made of cotton.... Steel hardware, protected against corrosion by plating, is not acceptable. Snap hook springs shall be phosphor bronze or other suitable corrosion-resistant material. Dee ring, o-ring, slide adjuster and snap...

  16. Cognitive Load Theory: How Many Types of Load Does It Really Need?

    Science.gov (United States)

    Kalyuga, Slava

    2011-01-01

    Cognitive load theory has been traditionally described as involving three separate and additive types of load. Germane load is considered as a learning-relevant load complementing extraneous and intrinsic load. This article argues that, in its traditional treatment, germane load is essentially indistinguishable from intrinsic load, and therefore…

  17. RFLP for Duchenne muscular dystrophy cDNA clone 30-2

    Energy Technology Data Exchange (ETDEWEB)

    Walker, A P; Bartlett, R J; Laing, N G; Siddique, T; Yamaoka, L H; Chen, J C; Hung, W Y; Roses, A D [Duke Univ. Medical Center, Durham, NC (USA)

    1988-09-26

    30-2 is one of 6 cDNA clones which comprise the cDNA for the Duchenne muscular dystrophy gene. It is a 1.15 kb fragment in the EcoRI site of Bluescribe. TaqI (T{down arrow}CGA) identifies two bands with alleles at 3.7 and 3.5 kb, as well as eight constant bands at 9.0, 7.5, 4.6, 3.6, 3.4, 2.5, 1.7 and 1.4 kb. The allele frequency was studied in 47 unrelated DMD males: 3.7 kb allele 0.45; and 3.5 kb allele 0.55. Co-dominant X-linked segregation was demonstrated in two 2-generation families. 1.1% agarose gels required to resolve the bands. The polymorphism is also recognized by PERT 87-15.

  18. Can `loss and damage' carry the load?

    Science.gov (United States)

    Verchick, Robert R. M.

    2018-05-01

    Even assuming a heroic rush towards carbon reduction and adaptation, some regions of the world will be hammered hard by climate impacts. Thus, a global consensus now sees the need for a supplemental plan to deal with the kind of harms that cannot be avoided-what Parties call `loss and damage'. For a loss-and-damage plan to work, it must be capable of carrying the load, the load being whatever minimal standards that morality and political consensus require. But if residual risk climbs too high, it will fall short of even the most basic expectations. The Paris Agreement calls for holding the rise in global average temperature to `well below 2°C above pre-industrial levels', while working to limit the increase to 1.5°C. How much difference is in that half-degree? From the point of view of residual risk, quite a lot. According to a 2016 study published by the European Geosciences Union, a jump from 1.5°C to 2°C could produce outsize impacts, particularly in tropical latitudes. That difference could mark the line between a plan that is politically and morally defensible and one that is not. At the very least, the difference is enough to inform the design and expectations of any future plan. This article is part of the theme issue `The Paris Agreement: understanding the physical and social challenges for a warming world of 1.5°C above pre-industrial levels'.

  19. Methodology of demand forecast by market analysis of electric power and load curves

    International Nuclear Information System (INIS)

    Barreiro, C.J.; Atmann, J.L.

    1989-01-01

    A methodology for demand forecast of consumer classes and their aggregation is presented. An analysis of the actual attended market can be done by appropriate measures and load curves studies. The suppositions for the future market behaviour by consumer classes (industrial, residential, commercial, others) are shown, and the actions for optimise this market are foreseen, obtained by load curves modulations. The process of future demand determination is obtained by the appropriate aggregation of this segmented demands. (C.G.C.)

  20. The cyclophilin inhibitor Debio-025 shows potent anti-hepatitis C effect in patients coinfected with hepatitis C and human immunodeficiency virus.

    Science.gov (United States)

    Flisiak, Robert; Horban, Andrzej; Gallay, Philippe; Bobardt, Michael; Selvarajah, Suganya; Wiercinska-Drapalo, Alicja; Siwak, Ewa; Cielniak, Iwona; Higersberger, Jozef; Kierkus, Jarek; Aeschlimann, Christian; Grosgurin, Pierre; Nicolas-Métral, Valérie; Dumont, Jean-Maurice; Porchet, Hervé; Crabbé, Raf; Scalfaro, Pietro

    2008-03-01

    Debio-025 is an oral cyclophilin (Cyp) inhibitor with potent anti-hepatitis C virus activity in vitro. Its effect on viral load as well as its influence on intracellular Cyp levels was investigated in a randomized, double-blind, placebo-controlled study. Mean hepatitis C viral load decreased significantly by 3.6 log(10) after a 14-day oral treatment with 1200 mg twice daily (P CypB) levels in peripheral blood mononuclear cells decreased from 67 +/- 6 (standard error) ng/mg protein (baseline) to 5 +/- 1 ng/mg protein at day 15 (P CypB levels, coinciding with the decrease in hepatitis C viral load. These are the first preliminary human data supporting the hypothesis that CypB may play an important role in hepatitis C virus replication and that Cyp inhibition is a valid target for the development of anti-hepatitis C drugs.

  1. Advanced aircraft service life monitoring method via flight-by-flight load spectra

    Science.gov (United States)

    Lee, Hongchul

    This research is an effort to understand current method and to propose an advanced method for Damage Tolerance Analysis (DTA) for the purpose of monitoring the aircraft service life. As one of tasks in the DTA, the current indirect Individual Aircraft Tracking (IAT) method for the F-16C/D Block 32 does not properly represent changes in flight usage severity affecting structural fatigue life. Therefore, an advanced aircraft service life monitoring method based on flight-by-flight load spectra is proposed and recommended for IAT program to track consumed fatigue life as an alternative to the current method which is based on the crack severity index (CSI) value. Damage Tolerance is one of aircraft design philosophies to ensure that aging aircrafts satisfy structural reliability in terms of fatigue failures throughout their service periods. IAT program, one of the most important tasks of DTA, is able to track potential structural crack growth at critical areas in the major airframe structural components of individual aircraft. The F-16C/D aircraft is equipped with a flight data recorder to monitor flight usage and provide the data to support structural load analysis. However, limited memory of flight data recorder allows user to monitor individual aircraft fatigue usage in terms of only the vertical inertia (NzW) data for calculating Crack Severity Index (CSI) value which defines the relative maneuver severity. Current IAT method for the F-16C/D Block 32 based on CSI value calculated from NzW is shown to be not accurate enough to monitor individual aircraft fatigue usage due to several problems. The proposed advanced aircraft service life monitoring method based on flight-by-flight load spectra is recommended as an improved method for the F-16C/D Block 32 aircraft. Flight-by-flight load spectra was generated from downloaded Crash Survival Flight Data Recorder (CSFDR) data by calculating loads for each time hack in selected flight data utilizing loads equations. From

  2. Comparison of Two Different Methods Used for Semen Evaluation: Analysis of Semen Samples from 1,055 Men.

    Science.gov (United States)

    Dinçer, Murat; Kucukdurmaz, Faruk; Salabas, Emre; Ortac, Mazhar; Aktan, Gulsan; Kadioglu, Ates

    2017-01-01

    The aim of this study was to evaluate whether there is a difference between gravimetrically and volumetrically measured semen samples and to assess the impact of semen volume, density, and sperm count on the discrepancy between gravimetric and volumetric methods. This study was designed in an andrology laboratory setting and performed on semen samples of 1,055 men receiving infertility treatment. Semen volume was calculated by gravimetric and volumetric methods. The total sperm count, semen density and sperm viability were also examined according to recent version of World Health Organization manual. The median values for gravimetric and volumetric measurements were 3.44 g and 2.96 ml respectively. The numeric difference in semen volume between 2 methods was 0.48. The mean density of samples was 1.01 ± 0.46 g/ml (range 0.90-2.0 g/ml). The numeric difference between 2 methods gets higher as semen volume increases (p semen volume measurements were strongly correlated for all samples and for each subgroup of semen volume, semen density and sperm count, with minimum correlation coefficient of 0.895 (p semen volume increases. However, further studies are needed to offer the use of gravimetrical method, which was thought to minimize laboratory errors, particularly for a high amount of semen samples. © 2016 S. Karger AG, Basel.

  3. Interaction between physical and psychosocial work risk factors for low back symptoms and its consequences amongst Indonesian coal mining workers.

    Science.gov (United States)

    Widanarko, Baiduri; Legg, Stephen; Devereux, Jason; Stevenson, Mark

    2015-01-01

    This study assessed the interaction between physical and psychosocial factors for low back symptoms (LBS) and its consequences (reduced activities and absenteeism) in a developing country. A sample of 1294 Indonesian coal mining workers reported occupational exposures, LBS and its consequences using a self-administered questionnaire. Respondents were placed into one of four combination exposure groups: high physical and high psychosocial (HPhyHPsy); high physical and low psychosocial (HPhyLPsy); low physical and high psychosocial (LPhyHPsy), and; low physical and low psychosocial (LPhyLPsy). The attributable proportion due to interaction between physical and psychosocial factors was examined. Individuals in the HPhyHPsy group were most likely to report LBS (OR 5.42, 95% CI 3.30-8.89), reduced activities (OR 4.89, 95% CI 3.09-7.74), and absenteeism (OR 4.96, 95% CI 3.05-8.06). Interactions between physical and psychosocial factors were present for LBS, reduced activities, and absenteeism; although for LBS and absenteeism the interactions were not significant. Current smokers were more likely to report LBS consequences. Permanent employment and night shift work increased the odds of LBS and its consequences. We conclude that interventions aimed at reducing LBS and its consequences should address both physical and psychosocial factors, with a focus on smokers, permanent employment and night shift work. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  4. ATP is stored in lamellar bodies to activate vesicular P2X4 in an autocrine fashion upon exocytosis.

    Science.gov (United States)

    Fois, Giorgio; Winkelmann, Veronika Eva; Bareis, Lara; Staudenmaier, Laura; Hecht, Elena; Ziller, Charlotte; Ehinger, Konstantin; Schymeinsky, Jürgen; Kranz, Christine; Frick, Manfred

    2018-02-05

    Vesicular P2X 4 receptors are known to facilitate secretion and activation of pulmonary surfactant in the alveoli of the lungs. P2X 4 receptors are expressed in the membrane of lamellar bodies (LBs), large secretory lysosomes that store lung surfactant in alveolar type II epithelial cells, and become inserted into the plasma membrane after exocytosis. Subsequent activation of P2X 4 receptors by adenosine triphosphate (ATP) results in local fusion-activated cation entry (FACE), facilitating fusion pore dilation, surfactant secretion, and surfactant activation. Despite the importance of ATP in the alveoli, and hence lung function, the origin of ATP in the alveoli is still elusive. In this study, we demonstrate that ATP is stored within LBs themselves at a concentration of ∼1.9 mM. ATP is loaded into LBs by the vesicular nucleotide transporter but does not activate P2X 4 receptors because of the low intraluminal pH (5.5). However, the rise in intravesicular pH after opening of the exocytic fusion pore results in immediate activation of vesicular P2X 4 by vesicular ATP. Our data suggest a new model in which agonist (ATP) and receptor (P2X 4 ) are located in the same intracellular compartment (LB), protected from premature degradation (ATP) and activation (P2X 4 ), and ideally placed to ensure coordinated and timely receptor activation as soon as fusion occurs to facilitate surfactant secretion. © 2018 Fois et al.

  5. Dynamical load factor of impact loaded shell structures

    International Nuclear Information System (INIS)

    Hammel, J.

    1977-01-01

    Dynamical loaded structures can be analysed by spectral representations, which usually lead to an enormous computational effort. If it is possible to find a fitting dynamical load factor, the dynamical problem can be reduced to a statical one. The computation of this statical problem is much simpler. The disadvantage is that the dynamical load factor usually leads to a very rough approximation. In this paper it will be shown, that by combination of these two methods, the approximation of the dynamical load factor can be improved and the consumption of computation time can be enormously reduced. (Auth.)

  6. ANALISIS PENGARUH KONFIGURASI EIGRP EQUAL DAN UNEQUAL COST LOAD BALANCING TERHADAP KINERJA ROUTER

    Directory of Open Access Journals (Sweden)

    Dian Bagus Saptonugroho

    2015-04-01

    Full Text Available Routing protocol is tasked with finding the best route to send the packet. Assessed using the metric. If there is more than one route with the same metric value, Routing Information Path (RIP, Open Shortest Path First (OSPF, and Enhanched Interior Gateway Routing Protocol (EIGRP support equal cost load balancing to send packets to the destination. If there is more than one route with a different metric values, EIGRP can do unequal cost load balancing. Research needs to be conducted to determine the effect of the configuration of EIGRP equal and unequal cost load balancing on the performance of the router which can be used as a proof-of-concept testing that is part of the project design document on a network. Research networks using EIGRP as the routing protocol. After the equal and unequal load balancing is enabled by configuring the variance, CEF, per-destination load balancing, per-packet load balancing, or traffic sharing and analyzing its effect on the neighbor table, topology table, routing table, the data transmission, survivability, convergence, throughput, and utilization. This study used an emulator GNS3 as Cisco 2691 Router with Cisco IOS version 12:24 (25 c and advanced enterprise-adventerprisek9 image c2691-mz.124-25c.bin, and OPNET Modeler 14.5 for simulation. The results of the study can be used as a proof-of-concept testing in the design document for later use as contemplated in the manufacture of plan implementation and verification plan.

  7. Developing strategies to enhance loading efficiency of erythrosensors

    Science.gov (United States)

    Bustamante Lopez, Sandra C.; Ritter, Sarah C.; Meissner, Kenith E.

    2014-02-01

    For diabetics, continuous glucose monitoring and the resulting tighter control of glucose levels ameliorate serious complications from hypoglycemia and hyperglycemia. Diabetics measure their blood glucose levels multiple times a day by finger pricks, or use implantable monitoring devices. Still, glucose and other analytes in the blood fluctuate throughout the day and the current monitoring methods are invasive, immunogenic, and/or present biodegradation problems. Using carrier erythrocytes loaded with a fluorescent sensor, we seek to develop a biodegradable, efficient, and potentially cost effective method to continuously sense blood analytes. We aim to reintroduce sensor-loaded erythrocytes to the bloodstream and conserve the erythrocytes lifetime of 120 days in the circulatory system. Here, we compare the efficiency of two loading techniques: hypotonic dilution and electroporation. Hypotonic dilution employs hypotonic buffer to create transient pores in the erythrocyte membrane, allowing dye entrance and a hypertonic buffer to restore tonicity. Electroporation relies on controlled electrical pulses that results in reversible pores formation to allow cargo entrance, follow by incubation at 37°C to reseal. As part of the cellular characterization of loaded erythrocytes, we focus on cell size, shape, and hemoglobin content. Cell recovery, loading efficiency and cargo release measurements render optimal loading conditions. The detected fluorescent signal from sensor-loaded erythrocytes can be translated into a direct measurement of analyte levels in the blood stream. The development of a suitable protocol to engineer carrier erythrocytes has profound and lasting implications in the erythrosensor's lifespan and sensing capabilities.

  8. Research of Impact Load in Large Electrohydraulic Load Simulator

    Directory of Open Access Journals (Sweden)

    Yongguang Liu

    2014-01-01

    Full Text Available The stronger impact load will appear in the initial phase when the large electric cylinder is tested in the hardware-in-loop simulation. In this paper, the mathematical model is built based on AMESim, and then the reason of the impact load is investigated through analyzing the changing tendency of parameters in the simulation results. The inhibition methods of impact load are presented according to the structural invariability principle and applied to the actual system. The final experimental result indicates that the impact load is inhibited, which provides a good experimental condition for the electric cylinder and promotes the study of large load simulator.

  9. Load research manual. Volume 2. Fundamentals of implementing load research procedures

    Energy Technology Data Exchange (ETDEWEB)

    Brandenburg, L.; Clarkson, G.; Grund, Jr., C.; Leo, J.; Asbury, J.; Brandon-Brown, F.; Derderian, H.; Mueller, R.; Swaroop, R.

    1980-11-01

    This three-volume manual presents technical guidelines for electric utility load research. Special attention is given to issues raised by the load data reporting requirements of the Public Utility Regulatory Policies Act of 1978 and to problems faced by smaller utilities that are initiating load research programs. In Volumes 1 and 2, procedures are suggested for determining data requirements for load research, establishing the size and customer composition of a load survey sample, selecting and using equipment to record customer electricity usage, processing data tapes from the recording equipment, and analyzing the data. Statistical techniques used in customer sampling are discussed in detail. The costs of load research also are estimated, and ongoing load research programs at three utilities are described. The manual includes guides to load research literature and glossaries of load research and statistical terms.

  10. Electrochemical evaluation of La{sub 0.6}Sr{sub 0.4}CoO{sub 3}-La{sub 0.45}Ce{sub 0.55}O{sub 2} composite cathodes for anode-supported La{sub 0.45}Ce{sub 0.55}O{sub 2}-La{sub 0.9}Sr{sub 0.1}Ga{sub 0.8}Mg{sub 0.2}O{sub 2.85} bilayer electrolyte solid oxide fuel cells

    Energy Technology Data Exchange (ETDEWEB)

    Bi, Zhonghe; Cheng, Mojie; Dong, Yonglai; Wu, Hejin; She, Yunchuan; Yi, Baolian [Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023 (China)

    2005-02-28

    The electrochemical properties of porous composite cathodes of La{sub 0.6}Sr{sub 0.4}CoO{sub 3} (LSC) and La{sub 0.45}Ce{sub 0.55}O{sub 2} (LDC) in anode supported lanthanum-doped ceria (LDC)/lanthanum gallate (LSGM) bilayer electrolyte single cells have been investigated. The composite cathodes with different LDC and LSC contents were in contact with the LSGM layer in the single cells. Comparing with the pure LSC cathode, the interfacial resistance decreased upon the addition of LDC and the optimum content of LDC was 50 wt.%. The variation in ohmic resistance suggests that the composite cathode can suppress Co diffusion from the cathode into the LSGM electrolyte during the firing of the composite cathode onto the electrolyte. The composite cathode with 50 wt.% LDC showed an ohmic resistance near to the calculated resistance of an electrolyte film. For the pure LSC cathode, the optimum firing temperature was about 1150 {sup o}C, at which both the electrolyte resistance and interface resistance were the smallest. The cathodic interfacial resistance was effectively reduced for the composite cathodes, especially for the cathode with 50 wt.% LDC, which might be due to the suppressing of sintering and the growth of LSC particles from LDC particles during the firing onto the electrolyte. The complicated effects of the composite cathode on the interfacial resistance and ohmic resistance resulted in the best single cell performance at 650 {sup o}C with a 50 wt.% LDC composite cathode, and the best cell performance above 700 {sup o}C on the single cell with pure LSC cathode.

  11. Effect of ripple loads on sustained-load cracking in titanium alloys

    International Nuclear Information System (INIS)

    Pao, P.S.; Meyn, D.A.; Bayles, R.A.; Feng, C.R.; Yoder, G.R.

    1995-01-01

    In the present paper, the authors have extended their study on the effect of the ripple loads on the sustained-load cracking (SLC) behavior of two titanium alloys, Ti-6Al-4V (an α-β alloy) and Ti-15V-3Cr-3Al-3Sn (a β-α alloy), in an ambient air environment. The methodology which has been used successfully to treat ripple effects on stress-corrosion cracking (SCC) is employed again to address the influence of ripple loads on sustained-load cracking. Ripple loads can significantly reduce the apparent sustained load cracking resistance of titanium alloys in a relatively benign environment such as ambient air. For a ripple-load amplitude equal to 5% of the sustained load, the ripple-load cracking thresholds (K IRLC ) of beta-annealed Ti-6Al-4V and Ti-15V-3Cr-3al-3Sn are less than half of the respective sustained-load cracking thresholds (K ISLC ). The extent of ripple-load degradation for these alloys in ambient air -- relative to K ISLC , were found comparable to those observed in a much more aggressive 3.5% NaCl aqueous solution

  12. Computerized counseling reduces HIV-1 viral load and sexual transmission risk: findings from a randomized controlled trial.

    Science.gov (United States)

    Kurth, Ann E; Spielberg, Freya; Cleland, Charles M; Lambdin, Barrot; Bangsberg, David R; Frick, Pamela A; Severynen, Anneleen O; Clausen, Marc; Norman, Robert G; Lockhart, David; Simoni, Jane M; Holmes, King K

    2014-04-15

    Evaluate a computerized intervention supporting antiretroviral therapy (ART) adherence and HIV transmission prevention. Longitudinal randomized controlled trial. An academic HIV clinic and a community-based organization in Seattle. In a total of 240 HIV-positive adults on ART, 209 completed 9-month follow-up (87% retention). Randomization to computerized counseling or assessment only, 4 sessions over 9 months. HIV-1 viral suppression, and self-reported ART adherence and transmission risks, compared using generalized estimating equations. Overall, intervention participants had reduced viral load: mean 0.17 log10 decline, versus 0.13 increase in controls, P = 0.053, and significant difference in ART adherence baseline to 9 months (P = 0.046). Their sexual transmission risk behaviors decreased (odds ratio = 0.55, P = 0.020), a reduction not seen among controls (odds ratio = 1.1, P = 0.664), and a significant difference in change (P = 0.040). Intervention effect was driven by those most in need; among those with detectable virus at baseline (>30 copies/mL, n = 89), intervention effect was mean 0.60 log10 viral load decline versus 0.15 increase in controls, P = 0.034. ART adherence at the final follow-up was 13 points higher among intervention participants versus controls, P = 0.038. Computerized counseling is promising for integrated ART adherence and safer sex, especially for individuals with problems in these areas. This is the first intervention to report improved ART adherence, viral suppression, and reduced secondary sexual transmission risk behavior.

  13. Response to severe changes of load on the reactor system of nuclear ship Mutsu

    International Nuclear Information System (INIS)

    Ishida, Toshihisa; Kusunoki, Tsuyoshi; Ochiai, Masa-aki; Tanaka, Yoshimi; Yao, Toshiaki; Inoue, Kimio.

    1993-01-01

    The response of the nuclear power system of N.S. Mutsu to severe changes of load have been studied from records taken during the power-raising tests performed on the ship in 1990. The records examined were those involving the most severe load changes foreseen for marine reactors: (a) sharp load increase with total steam flow raised from 25 to 70 % rated full flow in 13s, (b) crash astern maneuver with the position of propulsion turbine command handle changed-taking several seconds-from cruising ahead to STOP, and after about 50s, further changed-taking 30s-to bring the astern propulsion turbine to full speed-to consume approximately 60 % rated total steam flow and (c) turbine trip with the ahead turbine intentionally tripped when operating at roughly 100 % rated total steam flow. The foregoing records from load changes-of severity beyond what is foreseen for land-based reactors-proved that the Mutsu reactor is capable of responding smoothly and securely to such severe load changes. These load changes occasioned relatively large mismatches between reactor power supply and steam flow demand, but with notable freedom from any conspicuous overshooting or hunting of the reactor power. This performance can be attributed to (a) correct functioning of the automatic power control system, (b) effective contribution of the self-regulating reactor control property deriving from the large negative feedback between moderator temperature and reactivity, and (c) the ample inventories of coolant in the primary and secondary loops. The responses to load change are discussed covering those relevant to (a) reactor power, (b) primary loop pressure, and (c) steam generator pressure, with particular reference to the differences seen in response to mild and to severe load changes. (author)

  14. In situ loading of Ag_2WO_4 on ultrathin g-C_3N_4 nanosheets with highly enhanced photocatalytic performance

    International Nuclear Information System (INIS)

    Li, Yunfeng; Jin, Renxi; Fang, Xu; Yang, Yang; Yang, Man; Liu, Xianchun; Xing, Yan; Song, Shuyan

    2016-01-01

    Graphical abstract: Ultrathin g-C_3N_4 nanosheets (g-C_3N_4−NS) with improved electron transport ability and large number of active sites are employed instead of bulk g-C_3N_4 to prepare the Ag_2WO_4/g-C_3N_4−NS heterostructured photocatalysts, which exhibit remarkable photocatalytic activity for wastewater treatment. - Highlights: • Ag2WO4/g-C3N4-NS photocatalysts were obtained by a deposition-precipitation method. • Ag2WO4/g-C3N4-NS possess large surface areas and increased lifetime of charges. • Ag2WO4/g-C3N4-NS exhibit enhanced activity on degradation of RhB and MO. • The photocatalytic mechanism of the Ag2WO4/g-C3N4-NS system were investigated. - Abstract: The g-C_3N_4 nanosheets (g-C_3N_4−NS) exhibit more excellent property than common bulk g-C_3N_4 (g-C_3N_4-B) due to their large surface areas, improved electron transport ability and well dispersion in water. In this work, ultrathin g-C_3N_4−NS with a thickness of about 2.7 nm have been synthesized by a simple thermal exfoliation of bulk g-C_3N_4, and then Ag_2WO_4 nanoparticles are in situ loaded on their surface to construct the Ag_2WO_4/g-C_3N_4−NS heterostructured photocatalysts. Due to their unique physicochemical properties, the as-prepared heterostructures possess a fast interfacial charge transfer and increased lifetime of photo-excited charge carriers, and exhibit much higher photocatalytic activity. Under visible light irradiation, the optimum photocatalytic activity of Ag_2WO_4/g-C_3N_4−NS composites is almost 53.6 and 26.5 times higher than that of pure g-C_3N_4-B and Ag_2WO_4/g-C_3N_4-B heterostructures towards the degradation of rhodamine B, respectively, and is almost 30.6 and 9.8 times higher towards the degradation of methyl orange, respectively. In addition, the natural sunlight photocatalytic activities of the as-prepared samples are also investigated.

  15. Dirt feedlot residue experiments. Quarterly progress report, December 1977--March 1978

    Energy Technology Data Exchange (ETDEWEB)

    Turk, M.

    1978-04-01

    Performance of the mobile fermentation system is reported. It made use of aged pen residue at the nominal loading rate of 0.25 lbs. volatile solids/ft./sup 3//day with a 10-day retention time and a fermentation temperature of 57/sup 0/C. Results of an experimental cattle feeding trial utilizing the protein in the fermentor liquid effluent as a replacement for standard protein supplements were encouraging. The evaluation of the capture efficiency of the system centrifuge both with and without a chemical flocculant was completed. An experimental cattle feeding trial utilizing the protein fermentation product (PFP) harvested by the centrifuge as replacement for the standard protein supplementwas initiated. The characterization of the cattle residues found in various cattle pens, feedlots, and locations was continued. An investigation was initiated into methods of separating the organic content of the feedlot residue from the sand and grit content. (JGB)

  16. Development of unidirectional C/C composite with high thermal conductivity and its application to plasma facing materials

    Energy Technology Data Exchange (ETDEWEB)

    Ioki, Kimihiro (Mitsubishi Atomic Power Industries, Inc., Tokyo (Japan)); Onozuka, Masanori; Ikeda, Takeshi; Akiba, Masato

    1994-03-01

    Unidirectional C/C composite named 'MFC-1' with high conductivity was developed, and full-scale armor tiles were fabricated. The thermal conductivity in the direction perpendicular to the plasma-side surface is more than 300-500 W/m[center dot]degC, which is higher than those of other C/C composites ever made, even superior to that of pyrolytic carbon. It was shown by high heat load tests done using an electron beam test facility that the unidirectional C/C composite was very resistant against both surface erosion as well as severe thermal shock. The 'MFC-1' was successfully brazed to copper substrate, and its high thermal shock resistance was observed in heat load tests (20 MW/m[sup 2], 3s, not cooled). A functionally gradient material has been also developed as compliant layer for the MFC-1 bonded to copper. (author).

  17. Low cognitive load strengthens distractor interference while high load attenuates when cognitive load and distractor possess similar visual characteristics.

    Science.gov (United States)

    Minamoto, Takehiro; Shipstead, Zach; Osaka, Naoyuki; Engle, Randall W

    2015-07-01

    Studies on visual cognitive load have reported inconsistent effects of distractor interference when distractors have visual characteristic that are similar to the cognitive load. Some studies have shown that the cognitive load enhances distractor interference, while others reported an attenuating effect. We attribute these inconsistencies to the amount of cognitive load that a person is required to maintain. Lower amounts of cognitive load increase distractor interference by orienting attention toward visually similar distractors. Higher amounts of cognitive load attenuate distractor interference by depleting attentional resources needed to process distractors. In the present study, cognitive load consisted of faces (Experiments 1-3) or scenes (Experiment 2). Participants performed a selective attention task in which they ignored face distractors while judging a color of a target dot presented nearby, under differing amounts of load. Across these experiments distractor interference was greater in the low-load condition and smaller in the high-load condition when the content of the cognitive load had similar visual characteristic to the distractors. We also found that when a series of judgments needed to be made, the effect was apparent for the first trial but not for the second. We further tested an involvement of working memory capacity (WMC) in the load effect (Experiment 3). Interestingly, both high and low WMC groups received an equivalent effect of the cognitive load in the first distractor, suggesting these effects are fairly automatic.

  18. Effects of Load and Speed on Wear Rate of Abrasive Wear for 2014 Al Alloy

    Science.gov (United States)

    Odabas, D.

    2018-01-01

    In this paper, the effects of the normal load and sliding speed on wear rate of two-body abrasive wear for 2014 Al Alloy were investigated in detail. In order to understand the variation in wear behaviour with load and speed, wear tests were carried out at a sliding distance of 11 m, a speed of 0.36 m/s, a duration of 30 s and loads in the range 3-11 N using 220 grit abrasive paper, and at a speed range 0.09-0.90 m/s, a load of 5 N and an average sliding distance of 11 m using abrasive papers of 150 grit size under dry friction conditions. Before the wear tests, solution treatment of the 2014 Al alloy was carried out at temperatures of 505 and 520 °C for 1 h in a muffle furnace and then quenched in cold water at 15 °C. Later, the ageing treatment was carried out at 185 °C for 8 h in the furnace. Generally, wear rate due to time increased linearly and linear wear resistance decreased with increasing loads. However, the wear rate was directly proportional to the load up to a critical load of 7 N. After this load, the slope of the curves decreased because the excessive deformation of the worn surface and the instability of the abrasive grains began to increase. When the load on an abrasive grain reaches a critical value, the groove width is about 0.17 of the abrasive grain diameter, and the abrasive grains begin to fail. The wear rate due to time increased slightly as the sliding speed increased in the range 0.09-0.90 m/s. The reason for this is that changes arising from strain rate and friction heating are expected with increasing sliding speeds.

  19. Tribological behavior of 440C martensitic stainless steel from -184 C to 750 C

    Science.gov (United States)

    Slifka, A. J.; Compos, R.; Morgan, T. J.; Siegwarth, J. D.; Chaudhuri, Dilip K.

    1992-01-01

    Characterization of the coefficient of friction and wear rate of 440C stainless steel is needed to understand the effects of frictional heating in the bearings of the High Pressure Oxygen Turbopump of the Space Shuttle Main Engine. The coefficient of friction and wear rate have been measured over a range of temperature varying from liquid oxygen temperature (-184 C) to 750 C. The normal load has also been varied resulting in a variation of Hertzian stress from 0.915 to 3.660 GPa while the surface velocity has been varied from 0.5 to 2.0 m/s.

  20. Mark III LOCA-related hydrodynamic load definition. Generic technical activity B-10

    International Nuclear Information System (INIS)

    1984-02-01

    This report, prepared by the staff of the Office of Nuclear Reactor Regulation and its consultants at the Brookhaven National Laboratory, provides a discussion of LOCA-related suppression pool hydrodynamic loads in boiling water reactor (BWR) facilities with the Mark III pressure-suppression containment design. Its issuance completes NRC Generic Technical Activity B-10, Behavior of BWR Mark III Containment. On the basis of certain large-scale tests conducted between 1973 and 1979, the General Electric Company developed LOCA-related hydrodynamic load definitions for use in the design of the standard Mark III containment. The staff and its consultants have reviewed these load definitions and their bases conclude that, with a few specified changes, the proposed load definitions provide conservative loading conditions. The staff-approved acceptance criteria for LOCA-related hydrodynamic loads are provided in Appendix C of this report

  1. 40 CFR Table 12 to Subpart Wwww of... - Data Requirements for New and Existing Continuous Lamination Lines and Continuous Casting Lines...

    Science.gov (United States)

    2010-07-01

    ... Continuous Lamination Lines and Continuous Casting Lines Complying With a Lbs/Ton Organic HAP Emissions Limit... Requirements for New and Existing Continuous Lamination Lines and Continuous Casting Lines Complying With a Lbs... with a lbs/ton organic HAP emissions limit for continuous lamination lines and continuous casting lines...

  2. Can manipulations of cognitive load be used to test evolutionary hypotheses?

    Science.gov (United States)

    Barrett, H Clark; Frederick, David A; Haselton, Martie G; Kurzban, Robert

    2006-09-01

    D. DeSteno, M. Y. Bartlett, J. Braverman, and P. Salovey proposed that if sex-differentiated responses to infidelity are evolved, then they should be automatic, and therefore cognitive load should not attenuate them. DeSteno et al. found smaller sex differences in response to sexual versus emotional infidelity among participants under cognitive load, an effect interpreted as evidence against the evolutionary hypothesis. This logic is faulty. Cognitive load probably affects mechanisms involved in simulating infidelity experiences, thus seriously challenging the usefulness of cognitive load manipulations in testing hypotheses involving simulation. The method also entails the assumption that evolved jealousy mechanisms are necessarily automatic, an assumption not supported by theory or evidence. Regardless of how the jealousy debate is eventually settled, cognitive load manipulations cannot rule out the operation of evolved mechanisms. ((c) 2006 APA, all rights reserved).

  3. Limit State of Trapezoidal Metal Sheets Exposed to Concentrated Load

    OpenAIRE

    Kateřina Jurdová

    2013-01-01

    In most industrial compounds are used trapezoidal metal sheets like a roof decks. These trapezoidal metal sheets are exposed by concentrated loads, usually by service loads arise from installation of air distribution, sanitary distribution, sprinkler system or wiring installation. In objects of public facilities (like shopping centre, tennis hall, etc.) they can be used for hanging advertising posters etc, too. These systems work as “building kit”. These anchoring systems are represented by c...

  4. Tank 241C106 structural evaluation in support of Project W320 retrieval

    International Nuclear Information System (INIS)

    Wallace, D.A.

    1994-10-01

    Tank 241C106 structural evaluation to support W320. It includes ACI code input and riser evaluations. This work uses the in situ conditions established by Julyk to develop a three-dimensional model of the tank. Non-axisymmetric loads associated with retrieval activities are applied to assess their influence on structural integrity of the tank. This study addresses loads associated with normal opertion and credible accident scenarios. The concrete structure of tank C106 is classified as a Safety Class I non-reactor structure in accordance with the definition given in SDC 4.1. The operating specifications document (OSD) limits applicable to tank C106 include a live load limit for the C Tank Farm of 100 tons. For the technical basis of this limit, the OSD references SD-RE-TI-012, which qualifies the 100 tons as that distributed over a 10-ft radius. However, there is no specification for a uniform live load that would accompany natural hazard phenomena such as snow or ash fall. There is no specific guidance on crane loads applied at the surface outside the tank radius. Further, there is no record of any seismic analysis of tanks in the C Tank Farm. The analysis documented in this report evaluates nonseismic conditions that include a concentrated live load, a uniform live load, and a crane load, in addition to the in situ loads. The model documented in this study also is used to provide the nonseismic stress contribution to the seismic load combination documented by Wallace

  5. Distribution load estimation (DLE)

    Energy Technology Data Exchange (ETDEWEB)

    Seppaelae, A; Lehtonen, M [VTT Energy, Espoo (Finland)

    1998-08-01

    The load research has produced customer class load models to convert the customers` annual energy consumption to hourly load values. The reliability of load models applied from a nation-wide sample is limited in any specific network because many local circumstances are different from utility to utility and time to time. Therefore there is a need to find improvements to the load models or, in general, improvements to the load estimates. In Distribution Load Estimation (DLE) the measurements from the network are utilized to improve the customer class load models. The results of DLE will be new load models that better correspond to the loading of the distribution network but are still close to the original load models obtained by load research. The principal data flow of DLE is presented

  6. Preparation of 5-fluorouracil loaded chitosan microparticle and its drug release properties

    Directory of Open Access Journals (Sweden)

    Li Mingming

    2017-01-01

    Full Text Available Chitosan is one kind of good biocompatible polymer and is suitble for drug carriers. Preparation of 5-fluorouracil (5-Fu loaded chitosan (CS particles and in vitro release experiment were performed using ionic crosslinking method with sodium tripolyphosphate (TPP as crosslinker. The optimal preparing parameters were verified by 5-Fu release experiments. The drug loading, and release behavior of drug loaded microparticles in vitro were investigated. The optimal preparation conditions were: the temperature 25°C, the ratio of CS to TPP 5:1, the CS concentration 1.5g/L, stirring speed 650rpm. Under these conditions, the drug loading of particles was up to 45%.

  7. Assessment of β-lapachone loaded in lecithin-chitosan nanoparticles for the topical treatment of cutaneous leishmaniasis in L. major infected BALB/c mice.

    Science.gov (United States)

    Moreno, Esther; Schwartz, Juana; Larrea, Esther; Conde, Iosune; Font, Maria; Sanmartín, Carmen; Irache, Juan Manuel; Espuelas, Socorro

    2015-11-01

    Patients affected by cutaneous leishmaniasis need a topical treatment which cures lesions without leaving scars. Lesions are produced not only by the parasite but also by an uncontrolled and persistent inflammatory immune response. In this study, we proposed the loading of β-lapachone (β-LP) in lecithin-chitosan nanoparticles (NP) for targeting the drug to the dermis, where infected macrophages reside, and promote wound healing. Although the loading of β-LP in NP did not influence the drug antileishmanial activity it was critical to achieve important drug accumulation in the dermis and permeation through the skin. When topically applied in Leishmania major infected BALB/c mice, β-LP NP achieved no parasite reduction but they stopped the lesion progression. Immuno-histopathological assays in CL lesions and quantitative mRNA studies in draining lymph nodes confirmed that β-LP exhibited anti-inflammatory activity leading to the down-regulation of IL-1β and COX-2 expression and a decrease of neutrophils infiltrate. Cutaneous leishmaniasis often leaves patients with unsightly scars due to the body's inflammatory response to the infection. The authors in this paper described topical treatment using β-lapachone (β- LP) loaded in lecithin-chitosan nanoparticles (NP) in an animal model. Results confirmed the reduction of inflammatory response without affecting the parasite killing efficacy. These findings would pave way for further clinical testing in the near future. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. In situ fatigue loading stage inside scanning electron microscope

    Science.gov (United States)

    Telesman, Jack; Kantzos, Peter; Brewer, David

    1988-01-01

    A fatigue loading stage inside a scanning electron microscopy (SEM) was developed. The stage allows dynamic and static high-magnification and high-resolution viewing of the fatigue crack initiation and crack propagation processes. The loading stage is controlled by a closed-loop servohydraulic system. Maximum load is 1000 lb (4450 N) with test frequencies ranging up to 30 Hz. The stage accommodates specimens up to 2 inches (50 mm) in length and tolerates substantial specimen translation to view the propagating crack. At room temperature, acceptable working resolution is obtainable for magnifications ranging up to 10,000X. The system is equipped with a high-temperature setup designed for temperatures up to 2000 F (1100 C). The signal can be videotaped for further analysis of the pertinent fatigue damage mechanisms. The design allows for quick and easy interchange and conversion of the SEM from a loading stage configuration to its normal operational configuration and vice versa. Tests are performed entirely in the in-situ mode. In contrast to other designs, the NASA design has greatly extended the life of the loading stage by not exposing the bellows to cyclic loading. The loading stage was used to investigate the fatigue crack growth mechanisms in the (100)-oriented PWA 1480 single-crystal, nickel-based supperalloy. The high-magnification observations revealed the details of the crack growth processes.

  9. Residential Load Manageability Factor Analyses by Load Sensitivity Affected by Temperature

    Directory of Open Access Journals (Sweden)

    N. Eskandari

    2016-12-01

    Full Text Available Load side management is the basic and significant principle to keeping the balance between generation side and consumption side of electrical power energy. Load side management on typical medium voltage feeder is the power energy consumption control of connected loads with variation of essential parameters that loads do reaction to their variation. Knowing amount of load's reaction to each parameters variation in typical medium voltage feeder during the day, leads to gain Load Manageability Factor (LMF for that specific feeder that helps power utilities to manage their connected loads. Calculating this LMF needs to find out each types of load with unique inherent features behavior to each parameters variation. This paper results and future work results will help us to catch mentioned LMF. In this paper analysis of residential load behavior due to temperature variation with training artificial neural network will be done. Load behavior due to other essential parameters variations like energy pricing variation, major event happening, and power utility announcing to the customers, and etc will study in future works. Collecting all related works results in a unit mathematical equation or an artificial neural network will gain LMF.

  10. The minor C-allele of rs2014355 in ACADS is associated with reduced insulin release following an oral glucose load

    DEFF Research Database (Denmark)

    Hornbak, Malene; Banasik, Karina; Justesen, Johanne Marie

    2011-01-01

    -aged Danish individuals (nACADS=4,324; nACADM=4,337). The T2D-case-control study involved a total of ~8,300 Danish individuals (nACADS=8,313; nACADM=8,344). Results In glucose-tolerant individuals the minor C-allele of rs2014355 of ACADS associated with reduced measures of serum insulin at 30 min following...... an oral glucose load (per allele effect (beta)=-3.8% (-6.3%;-1.3%), P=0.003), reduced incremental area under the insulin curve (beta=-3.6% (-6.3%;-0.9%), P=0.009), reduced acute insulin response (beta=-2.2% (-4.2%;0.2%), P=0.03), and with increased insulin sensitivity ISIMatsuda (beta= 2.9% (0.5%;5.2%), P...

  11. Ciprofloxacin-loaded PLGA nanoparticles against Cystic Fibrosis P. aeruginosa Lung Infections.

    OpenAIRE

    Günday Türeli, Nazende; Torge, Afra; Juntke, Jenny; Schwarz, Bianca C; Schneider-Daum, Nicole; Türeli, Akif Emre; Lehr, Claus-Michael; Schneider, Marc

    2017-01-01

    Current pulmonary treatments against Pseudomonasaeruginosa infections in cystic fibrosis (CF) lung suffer from deactivation of the drug and immobilization in thick and viscous biofilm/mucus blend, along with the general antibiotic resistance. Administration of nanoparticles (NPs) with high antibiotic load capable of penetrating the tight mesh of biofilm/mucus can be an advent to overcome the treatment bottlenecks. Biodegradable and biocompatible polymer nanoparticles efficiently loaded with c...

  12. Opposite Effects of Capacity Load and Resolution Load on Distractor Processing

    OpenAIRE

    Zhang, Weiwei; Luck, Steven J.

    2014-01-01

    According to the load theory of attention, an increased perceptual load reduces distractor processing whereas an increased working memory load facilitates distractor processing. Here we raise the possibility that the critical distinction may instead be between an emphasis on resolution and an emphasis on capacity. That is, perceptual load manipulations typically emphasize resolution (fine-grained discriminations), whereas working memory load manipulations typically emphasize capacity (simulta...

  13. A Comparison of Load-Velocity and Load-Power Relationships Between Well-Trained Young and Middle-Aged Males During Three Popular Resistance Exercises.

    Science.gov (United States)

    Fernandes, John F T; Lamb, Kevin L; Twist, Craig

    2018-05-01

    Fernandes, JFT, Lamb, KL, and Twist, C. A comparison of load-velocity and load-power relationships between well-trained young and middle-aged males during 3 popular resistance exercises. J Strength Cond Res 32(5): 1440-1447, 2018-This study examined the load-velocity and load-power relationships among 20 young (age 21.0 ± 1.6 years) and 20 middle-aged (age 42.6 ± 6.7 years) resistance-trained males. Participants performed 3 repetitions of bench press, squat, and bent-over-row across a range of loads corresponding to 20-80% of 1 repetition maximum (1RM). Analysis revealed effects (p velocity for all 3 exercises, and interaction effects on power for squat and bent-over-row (p bench press and bent-over-row, the young group produced higher barbell velocities, with the magnitude of the differences decreasing as load increased (ES; effect size 0.0-1.7 and 1.0-2.0, respectively). Squat velocity was higher in the young group than the middle-aged group (ES 1.0-1.7) across all loads, as was power for each exercise (ES 1.0-2.3). For all 3 exercises, both velocity and 1RM were correlated with optimal power in the middle-aged group (r = 0.613-0.825, p velocities at low external loads and power outputs as high as the young males across a range of external resistances. Moreover, the strong correlations between 1RM and velocity with optimal power suggest that middle-aged males would benefit from training methods which maximize these adaptations.

  14. Experimental control of the solvent load of inductively coupled argon plasmas and effects of the chloroform plasma load on their analytical performance

    Science.gov (United States)

    Maessen, F. J. M. J.; Kreuning, G.; Balke, J.

    The solvent plasma load ( QSPL) of water, methanol and chloroform was established as a function of the liquid uptake rate ( QL) by using a continuous weighing method for recording the rate differences between the relevant liquid streams. The shape of the QL vs QSPL curves revealed that the liquid uptake rate is a parameter much too insensitive to serve as a criterion for assessing the stability of "organic" plasmas. The quantity "maximum tolerable solvent plasma load" is suggested as a more useful criterion. Effects of rf power, observation height and solvent plasma load on the properties of chloroform inductively coupled plasmas (ICPs) are reported. The measurement of the axial distribution of net line intensities of representative spectral lines showed that the behaviour of emission lines as to their "hardness" is essentially the same in ICPs loaded with chloroform or water. The chloroform plasma load was regulated by the use of a condenser of which the temperature was varied in a range between -50°C and +20°C. Analytical performance characteristics such as net line and background intensities, signal-to-background ratios, and relative standard deviations of the background signal are presented for ICPs with various chloroform loads. Two sets of experimental conditions were finally selected for simultaneous multielement analysis of chloroform solvent solutions, one with and one without aerosol cooling. In the case that aerosol cooling was applied, the detection limits were similar to those for aqueous plasmas. Without aerosol cooling the detection limits were up to an order of magnitude poorer. An attempt has been made to catagorize organic solvents on the basis of both volatility and their behaviour in ICP systems. For a better understanding of the consequences of solvent volatility in ICP-AES it is of importance to consider separately the properties that determine the volatility of liquids, viz. the evaporation rate and the saturation vapour pressure.

  15. 40 CFR 86.529-98 - Road load force and inertia weight determination.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Road load force and inertia weight... inertia weight determination. (a)(1) Road load as a function of speed is given by the following equation: F = A + CV2 (2) The values for coefficients A and C and the test inertia are given in Figure F98-9...

  16. Pay for load demand - electricity pricing with load demand component

    International Nuclear Information System (INIS)

    Pyrko, Jurek; Sernhed, Kerstin; Abaravicius, Juozas

    2003-01-01

    This publication is part of a project called Direct and Indirect Load Control in Buildings. Peak load problems have attracted considerable attention in Sweden during last three winters, caused by a significant decrease in available reserve power, which is a consequence of political decisions and liberalisation of the electricity market. A possible way to lower peak loads, avoiding electricity shortages and reducing electricity costs both for users and utilities, is to make customers experience the price difference during peak load periods and, in this way, become more aware of their energy consumption pattern and load demand. As of January 1st 2001, one of the Swedish energy utilities - Sollentuna Energi - operating in the Stockholm area, introduced a new electricity tariff with differentiated grid fees based on a mean value of the peak load every month. This tariff was introduced for all residential customers in the service area. The objective of this study is to investigate the extent to which a Load Demand Component, included in electricity pricing, can influence energy use and load demand in residential buildings. What are the benefits and disadvantages for customers and utilities? This paper investigates the impact of the new tariff on the utility and different types of typical residential customers, making comparisons with previous tariff. Keywords Load demand, electricity pricing, tariff, residential customers, energy behaviour

  17. Concentrations and loads of nutrients in the tributaries of the Lake Okeechobee watershed, south-central Florida, water years 2004-2008

    Science.gov (United States)

    Byrne, Michael J.; Wood, Molly S.

    2011-01-01

    Lake Okeechobee in south-central Florida is the second largest freshwater lake in the contiguous United States. Excessive phosphorus loading, harmful high and low water levels, and rapid expansion of non-native vegetation have threatened the health of the lake in recent decades. A study was conducted to monitor discharge and nutrient concentrations from selected tributaries into Lake Okeechobee and to evaluate nutrient loads. The data analysis was performed at 16 monitoring stations from December 2003 to September 2008. Annual and seasonal discharge measured at monitoring stations is affected by rainfall. Hurricanes affected three wet years (2004, 2005, and the latter part of 2008) and resulted in substantially greater discharge than the drought years of 2006, 2007, and the early part of 2008. Rainfall supplies about 50 percent of the water to Lake Okeechobee, discharge from the Kissimmee River supplies about 25 percent, and discharge from tributaries and groundwater seepage along the lake perimeter collectively provide the remaining 25 percent. Annually, tributary discharge from basins located on the west side of the Kissimmee River is about 5 to 6 times greater than that from basins located on the east side. For the purposes of this study, the basins on the east side of the Kissimmee River are called "priority basins" because of elevated phosphorus concentrations, while those on the west side are called "nonpriority" basins. Total annual discharge in the non-priority basins ranged from 245,000 acre-feet (acre-ft) in 2007 to 1,322,000 acre-ft in 2005, while annual discharge from the priority basins ranged from 41,000 acre-ft in 2007 to 219,000 acre-ft in 2005. Mean total phosphorus concentrations ranged from 0.10 to 0.54 milligrams per liter (mg/L) at the 16 tributaries during 2004–2008. Mean concentrations were significantly higher at priority basin sites than at non-priority basin sites, particularly at Arbuckle Creek and C 41A Canal. Concentrations of organic

  18. Development of high conductive C/C composite tiles for plasma facing armor

    International Nuclear Information System (INIS)

    Ioki, K.; Namiki, K.; Tsujimura, S.; Toyoda, M.; Seki, M.; Takatsu, H.

    1991-01-01

    C/C composites with high thermal conductivity were developed in unidirectional, two-dimensional and felt types, and were fabricated as full-scale armor tile. Their thermal conductivity in the direction perpendicular to the plasma-side surface is 250∝550 W/mdeg C, that is comparable to that of pyrolytic graphite. It was shown by heat load tests that the C/C composites have low surface erosion characteristics and high thermal shock resistance. Various kinds of C/C composites were successfully bonded to metal substrate, and their mechanical strength and thermal shock resistance were tested. (orig.)

  19. Pt/C Fuel Cell Catalyst Degradation

    DEFF Research Database (Denmark)

    Zana, Alessandro

    This thesis investigates the degradation behavior of Pt/C catalysts under simulated automotive conditions. By using the “tool box” synthesis method the Pt loading has been changed from low to high Pt loadings, therefore permitting to study the role of Pt on the degradation of high surface area (H...

  20. THE VMC SURVEY. XVIII. RADIAL DEPENDENCE OF THE LOW-MASS, 0.55–0.82 M{sub ⊙} STELLAR MASS FUNCTION IN THE GALACTIC GLOBULAR CLUSTER 47 TUCANAE

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Chaoli; Li, Chengyuan; De Grijs, Richard [Kavli Institute for Astronomy and Astrophysics, Peking University, Yi He Yuan Lu 5, Hai Dian District, Beijing 100871 (China); Bekki, Kenji [ICRAR M468, The University of Western Australia, 35 Stirling Highway, Crawley, WA, 6009 (Australia); Deng, Licai; For, Bi-Qing [Key Laboratory for Optical Astronomy, National Astronomical Observatories, Chinese Academy of Sciences, 20A Datun Road, Chaoyang District, Beijing 100012 (China); Zaggia, Simone; Rubele, Stefano [INAF-Osservatorio Astronomico di Padova, vicolo dell’Osservatorio 5, I-35122 Padova (Italy); Piatti, Andrés E. [Observatorio Astrońomico, Universidad Nacional de Córdoba, Laprida 854, 5000, Córdoba (Argentina); Cioni, Maria-Rosa L. [Universität Potsdam, Institut für Physik und Astronomie, Karl-Liebknecht-Str. 24/25, D-14476 Potsdam (Germany); Emerson, Jim [Astronomy Unit, School of Physics and Astronomy, Queen Mary University of London, Mile End Road, London E1 4NS (United Kingdom); Ripepi, Vincenzo; Marconi, Marcella [INAF-Osservatorio Astronomico di Capodimonte, via Moiariello 16, I-80131 Naples (Italy); Ivanov, Valentin D. [European Southern Observatory, Karl-Schwarzschild-Str. 2, Garching bei München, D-85748 (Germany); Chen, Li, E-mail: jackzcl@outlook.com, E-mail: grijs@pku.edu.cn [Shanghai Astronomical Observatory, Chinese Academy of Sciences, Shanghai 200030 (China)

    2015-12-20

    We use near-infrared observations obtained as part of the Visible and Infrared Survey Telescope for Astronomy (VISTA) Survey of the Magellanic Clouds (VMC), as well as two complementary Hubble Space Telescope (HST) data sets, to study the luminosity and mass functions (MFs) as a function of clustercentric radius of the main-sequence stars in the Galactic globular cluster 47 Tucanae. The HST observations indicate a relative deficit in the numbers of faint stars in the central region of the cluster compared with its periphery, for 18.75 ≤ m{sub F606W} ≤ 20.9 mag (corresponding to a stellar mass range of 0.55 < m{sub *}/M{sub ⊙} < 0.73). The stellar number counts at 6.′7 from the cluster core show a deficit for 17.62 ≤ m{sub F606W} ≤ 19.7 mag (i.e., 0.65 < m{sub *}/M{sub ⊙} < 0.82), which is consistent with expectations from mass segregation. The VMC-based stellar MFs exhibit power-law shapes for masses in the range 0.55 < m{sub *}/M{sub ⊙} < 0.82. These power laws are characterized by an almost constant slope, α. The radial distribution of the power-law slopes α thus shows evidence of the importance of both mass segregation and tidal stripping, for both the first- and second-generation stars in 47 Tuc.

  1. Treatment response to the RENEW weight loss intervention in schizophrenia: impact of intervention setting.

    Science.gov (United States)

    Brown, Catana; Goetz, Jeannine; Hamera, Edna; Gajewski, Byron

    2014-11-01

    Individuals with serious mental illness have high rates of obesity and a need for specialized weight loss intervention programs. This study examines the efficacy of the RENEW weight loss intervention and examines the impact of the intervention setting on outcomes. 136 individuals with serious mental illness from 4 different settings were randomly assigned to receive the RENEW weight loss intervention or a control condition of treatment as usual. The RENEW intervention is a one year program that includes an intensive, maintenance and intermittent supports phase. The intervention group experienced a modest weight loss of 4.8 lbs at 3 months, 4.1 lbs at 6 months and a slight weight gain of 1.5 lbs at 12 months. The control group gained a total of 6.2 lbs at 12 months. However when settings were examined separately the responder sites had a weight loss of 9.4 lbs at 3 months, 10.9 lbs at 6 months and 7 lbs at 12 months. These results suggest that the settings in which individuals receive services may act as a support or hindrance toward response to weight loss interventions. The concept of the obesogenic environment deserves further examination as a factor in the success of weight loss programs. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. New Approaches to Attenuated Hepatitis a Vaccine Development: Cloning and Sequencing of Cell-Culture Adapted Viral cDNA.

    Science.gov (United States)

    1987-10-13

    after multiple passages in vivo and in vitro. J. Gen. Virol. 67, 1741- 1744. Sabin , A.B. (1985). Oral poliovirus vaccine : history of its development...IN (N NEW APPROACHES TO ATTENUATED HEPATITIS A VACCINE DEVELOPMENT: Q) CLONING AND SEQUENCING OF CELL-CULTURE ADAPTED VIRAL cDNA I ANNUAL REPORT...6ll02Bsl0 A 055 11. TITLE (Include Security Classification) New Approaches to Attenuated Hepatitis A Vaccine Development: Cloning and Sequencing of Cell

  3. Design of a creep experiment for SiC/SiC composites in HFIR

    Energy Technology Data Exchange (ETDEWEB)

    Hecht, S.L.; Hamilton, M.L.; Jones, R.H. [and others

    1997-08-01

    A new specimen was designed for performing in-reactor creep tests on composite materials, specifically on SiC/SiC composites. The design was tailored for irradiation at 800{degrees}C in a HFIR RB position. The specimen comprises a composite cylinder loaded by a pressurized internal bladder that is made of Nb1Zr. The experiment was designed for approximately a one year irradiation.

  4. Design of a creep experiment for SiC/SiC composites in HFIR

    International Nuclear Information System (INIS)

    Hecht, S.L.; Hamilton, M.L.; Jones, R.H.

    1997-01-01

    A new specimen was designed for performing in-reactor creep tests on composite materials, specifically on SiC/SiC composites. The design was tailored for irradiation at 800 degrees C in a HFIR RB position. The specimen comprises a composite cylinder loaded by a pressurized internal bladder that is made of Nb1Zr. The experiment was designed for approximately a one year irradiation

  5. Thermophilic co-digestion feasibility of distillers grains and swine manure: effect of C/N ratio and organic loading rate during high solid anaerobic digestion (HSAD).

    Science.gov (United States)

    Sensai, P; Thangamani, A; Visvanathan, C

    2014-01-01

    Anaerobic co-digestion of high solids containing distillers grains and swine manure (total solids, 27 +/- 2% and 18 +/- 2%, respectively) was evaluated in this study to assess the effect of C/N ratio and organic loading rate (OLR). Feed mixture was balanced to achieve a C/N ratio of 30/1 by mixing distillers grains and swine manure. Pilot-scale co-digestion of distillers grains and swine manure was carried out under thermophilic conditions in the continuous mode for seven different OLRs from R1 to R7 (3.5, 5, 6, 8, 10, 12 and 14 kg VS/m3 day) under high solid anaerobic digestion. The methane yield and volatile solid (VS) removal were consistent; ranging from 0.33 to 0.34 m3CH4/kg VS day and 50-53%, respectively, until OLR 8 kg VS/m3 day. After which methane yield and VS removal significantly decreased to 0.26 m3 CH4/kg VS day and 42%, respectively, when OLR was increased to 14 kg VS/m3 day. However, during operation, at OLR of 10 kg VS/m3 day, the methane yield and VS removal increased after the 19th day to 0.33 m3 CH4/kg VS day and 46%, respectively, indicating that a longer acclimatization period is required by methanogens at a higher loading rate.

  6. Influence of Al3+ substitution on the electrical resistivity and dielectric behavior of Ni0.25Cu0.20Zn0.55AlxFe2-xO4 ferrites synthesized by solid state reaction technique

    Science.gov (United States)

    Rahman, K. R.; Chowdhury, F.-U.-Z.; Khan, M. N. I.

    2017-12-01

    In this paper, the effect of Al3+ substitution on the electrical and dielectric properties of Ni0.25Cu0.20Zn0.55AlxFe2-xO4 ferrites with x = 0.0, 0.05. 0.10, 0.15 and 0.20, synthesized by solid state reaction has been reported. Using two probe method, the DC resistivity has been investigated in the temperature range from 30 °C to 300 °C. Activation energy was calculated from the Arrhenius plot. The electrical conduction is explained on the basis of the hopping mechanism. The frequency dependent dielectric properties of these spinel ferrites have been studied at room temperature by measuring AC resistivity, conductivity (σac), dielectric constant and dielectric loss tangent (tan δ) in the frequency range between 1 kHz and 120 MHz. The study of dielectric properties showed that the dielectric constant and dielectric loss increased with increasing non-magnetic Al ions. The dependence of dielectric constant with frequency has been explained by Maxwell-Wagner interfacial polarization. Cole-Cole plots show semicircular arc(s) for the samples, and equivalent RC circuits have been proposed to clarify the phenomena involved therein. The analysis of complex impedance spectroscopy has been used to distinguish between the grain and grain boundary contribution to the total resistance.

  7. Structural load combinations

    International Nuclear Information System (INIS)

    Hwang, H.; Reich, M.; Ellingwood, B.; Shinozuka, M.

    1985-01-01

    This paper presents the latest results of the program entitled, ''Probability Based Load Combinations For Design of Category I Structures''. In FY 85, a probability-based reliability analysis method has been developed to evaluate safety of shear wall structures. The shear walls are analyzed using stick models with beam elements and may be subjected to dead load, live load and in-plane eqrthquake. Both shear and flexure limit states are defined analytically. The limit state probabilities can be evaluated on the basis of these limit states. Utilizing the reliability analysis method mentioned above, load combinations for the design of shear wall structures have been established. The proposed design criteria are in the load and resistance factor design (LRFD) format. In this study, the resistance factors for shear and flexure and load factors for dead and live loads are preassigned, while the load factor for SSE is determined for a specified target limit state probability of 1.0 x 10 -6 or 1.0 x 10 -5 during a lifetime of 40 years. 23 refs., 9 tabs

  8. Structural load combinations

    International Nuclear Information System (INIS)

    Hwang, H.; Reich, M.; Ellingwood, B.; Shinozuka, M.

    1986-01-01

    This paper presents the latest results of the program entitled, ''Probability Based Load Combinations For Design of Category I Structures''. In FY 85, a probability-based reliability analysis method has been developed to evaluate safety of shear wall structures. The shear walls are analyzed using stick models with beam elements and may be subjected to dead load, live load and in-plane earthquake. Both shear and flexure limit states are defined analytically. The limit state probabilities can be evaluated on the basis of these limit states. Utilizing the reliability analysis method mentioned above, load combinations for the design of shear wall structures have been established. The proposed design criteria are in the load and resistance factor design (LRFD) format. In this study, the resistance factors for shear and flexure and load factors for dead and live loads are preassigned, while the load factor for SSE is determined for a specified target limit state probability of 1.0 x 10 -6 or 1.0 x 10 -5 during a lifetime of 40 years

  9. Site ultrasonic measurement on RPV stud-bolt loading under hot transient of Qinshan NPP

    International Nuclear Information System (INIS)

    Qu Jiadi; Dou Yikang; Zhu Shiming

    1994-08-01

    It expounds that the key of solving thermal transient sealing problem is to obtain the thermal increment of stud-bolt loading. This loading, as a primary stress loading, is directly related to the bolt fatigue life and transient loading spectrum for vessel analysis. The fundamental works and main results of ultrasonic measurement on RPV stud-bolt loading on Qinshan site are also presented. The measuring capability has exceeded 1 m in length and temperature of 280 degree C, therefore, it is possible to be used in the field of NPP. The paper is the continuation of research work for sealing analysis and tests on the RPV (see SMiRT-9, 10)

  10. Remedial shielding concepts for Line D and Line D facilities, Los Alamos Meson Physics Facility, Los Alamos National Laboratory, Los Alamos, New Mexico: Appendix 2. Final report

    International Nuclear Information System (INIS)

    Pye, J.H.

    1992-01-01

    This appendix contains the structural embankment analysis of the following Line D tunnel sections: 6(T/21), 5(21/21), 3(21/21), 2(21/21), 1(21/21), 2(21/24), 6(T/21), 3(23/23), 5(21/21)S, and 5(2/8). The structural assessment is for each section being covered with a 30 ft tuff berm used as shielding in the event of a beam spill. Each tunnel section is subject to vertical and horizontal loads estimated as 115 lbs/ft 2 for each 1 ft or overburden and horizontal loads equivalent to 0.2948 of the vertical load, due to the weight of the tuff berm placed over the structure. The profile of the berm is based on preliminary shielding assessments. Shear, axial and bending stresses are determined with the associated tunnel deformations

  11. Study on inelastic analysis method for structural design (1). Estimation method of loading history effect

    International Nuclear Information System (INIS)

    Tanaka, Yoshihiko; Kasahara, Naoto

    2003-05-01

    The advanced loop-type reactor system, one of the promising concepts in the Feasibility study of the FBR Cycle, adopts many innovative ideas to meet the challenging requirements for safety and economy. As a results, it seems that the structures of the reactor system would be subjected to severer loads than the predecessors. One of the countermeasures to them is the design by inelastic analysis. In the past, many studies showed that structural design by inelastic analysis is much more reasonable than one by conservative elastic analysis. However, inelastic analysis has hardly been adopted in nuclear design so far. One of the reasons is that inelastic analysis has loading history effect, that is, the analysis result would differ depending on the order of loads. It seems to be difficult to find the general solution for the loading history effect. Consequently, inelastic analysis output from the four deferent thermal load histories which consists of the thermal load cycle including the severest cold shock ('C') and the one including the severest hot shock ('H') were compared with each other. From this comparison, it was revealed that the thermal load history with evenly distributed 'H's among 'C's tend to give the most conservative damage estimation derived from inelastic analysis output. Therefore, such thermal load history pattern is proposed for the structural design by inelastic analysis. (author)

  12. Interface strength of SiC/SiC composites with and without helium implantation using micro-indentation test

    International Nuclear Information System (INIS)

    Saito, M.; Ohtsuka, S.

    1998-01-01

    Helium implantation effects on interface strength of SiC/SiC composite were studied using the micro-indentation fiber push-out method. Helium implantation was carried out with an accelerator at about 400 K. Total amount of implanted helium was approximately 10000 appm. Increase of the fiber push-in load was observed in as-implanted specimen. After post-implantation-annealing at 1673 K for 1 h, the change of the fiber push-in load by helium implantation was not observed. Effects of helium implantation on the interface are discussed. (orig.)

  13. Design, Construction, Testing and Evaluation of a Residential Ice Storage Air Conditioning System.

    Science.gov (United States)

    1982-11-01

    handler and chilled water coil from previous research. This was a necessity because of the financial constraints of ] the project. 2. The trailer was...Load lbs ice/12 hr Calculation Btuh req’d @ 8 FLEOB 1. NFPA 501 BM 25,043 1391 2. ACCA Manual J 27,571 1537 using manufacturer’sdata 3. ACCA Manual J...kilowatt hrf - ~0.197 (N da• y The equivalent ice requirement was estimated using the above data and 144 Btu/pound of ice. This does not account for any

  14. Distribution load estimation - DLE

    Energy Technology Data Exchange (ETDEWEB)

    Seppaelae, A. [VTT Energy, Espoo (Finland)

    1996-12-31

    The load research project has produced statistical information in the form of load models to convert the figures of annual energy consumption to hourly load values. The reliability of load models is limited to a certain network because many local circumstances are different from utility to utility and time to time. Therefore there is a need to make improvements in the load models. Distribution load estimation (DLE) is the method developed here to improve load estimates from the load models. The method is also quite cheap to apply as it utilises information that is already available in SCADA systems

  15. Distribution load estimation - DLE

    Energy Technology Data Exchange (ETDEWEB)

    Seppaelae, A [VTT Energy, Espoo (Finland)

    1997-12-31

    The load research project has produced statistical information in the form of load models to convert the figures of annual energy consumption to hourly load values. The reliability of load models is limited to a certain network because many local circumstances are different from utility to utility and time to time. Therefore there is a need to make improvements in the load models. Distribution load estimation (DLE) is the method developed here to improve load estimates from the load models. The method is also quite cheap to apply as it utilises information that is already available in SCADA systems

  16. Antifungal activity of fluconazole-loaded natural rubber latex against Candida albicans.

    Science.gov (United States)

    Yonashiro Marcelino, Mônica; Azevedo Borges, Felipe; Martins Costa, Ana Flávia; de Lacorte Singulani, Junya; Ribeiro, Nathan Vinícius; Barcelos Costa-Orlandi, Caroline; Garms, Bruna Cambraia; Soares Mendes-Giannini, Maria José; Herculano, Rondinelli Donizetti; Fusco-Almeida, Ana Marisa

    2018-03-01

    This work aimed to produce a membrane based on fluconazole-loaded natural rubber latex (NRL), and study their interaction, drug release and antifungal susceptibility against Candida albicans. Fluconazole-loaded NRL membrane was obtained by casting method. The Fourier Transform Infrared Spectroscopy showed no modifications either in NRL or fluconazole after the incorporation. Mechanical test presented low Young's modulus and high strain, indicating the membranes have sufficient elasticity for biomedical application. The bio-membrane was able to release the drug and inhibit the growth of C. albicans as demonstrated by disk diffusion and macrodilution assays. The biomembrane was able to release fluconazole and inhibit the growth of C. albicans, representing a promising biomaterial for skin application.

  17. Stimulus recognition occurs under high perceptual load: Evidence from correlated flankers.

    Science.gov (United States)

    Cosman, Joshua D; Mordkoff, J Toby; Vecera, Shaun P

    2016-12-01

    A dominant account of selective attention, perceptual load theory, proposes that when attentional resources are exhausted, task-irrelevant information receives little attention and goes unrecognized. However, the flanker effect-typically used to assay stimulus identification-requires an arbitrary mapping between a stimulus and a response. We looked for failures of flanker identification by using a more-sensitive measure that does not require arbitrary stimulus-response mappings: the correlated flankers effect. We found that flanking items that were task-irrelevant but that correlated with target identity produced a correlated flanker effect. Participants were faster on trials in which the irrelevant flanker had previously correlated with the target than when it did not. Of importance, this correlated flanker effect appeared regardless of perceptual load, occurring even in high-load displays that should have abolished flanker identification. Findings from a standard flanker task replicated the basic perceptual load effect, with flankers not affecting response times under high perceptual load. Our results indicate that task-irrelevant information can be processed to a high level (identification), even under high perceptual load. This challenges a strong account of high perceptual load effects that hypothesizes complete failures of stimulus identification under high perceptual load. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  18. High prevalence of the c.74A>C SPINK1 variant in miniature and standard Schnauzers.

    Science.gov (United States)

    Furrow, E; Armstrong, P J; Patterson, E E

    2012-01-01

    Variants in the serine protease inhibitor Kazal type 1 (SPINK1) gene have been associated with pancreatitis in Miniature Schnauzers. Replication of the association in an independent population is necessary to determine if genetic screening for SPINK1 variants should be considered in clinical practice. An association between the SPINK1 exonic variant c.74A > C and pancreatitis exists in Miniature Schnauzers. In addition, the variant is absent or rare in Standard Schnauzers, a related breed that is not reported to have an increased risk for pancreatitis. Case-control study. Seventeen Miniature Schnauzers with pancreatitis (cases), 60 mature Miniature Schnauzers with no substantial history of gastrointestinal signs in their lifetime (controls), and 31 Standard Schnauzers of unknown pancreatitis status. A PCR-RFLP assay was used to genotype dogs for the c.74A > C SPINK1 variant. Allele and genotype frequencies were reported for Schnauzers and compared between case and control Miniature Schnauzers. The c.74A > C variant was the major allele in both Schnauzer breeds with a frequency of 0.77 in Miniatures and 0.55 in Standards. The allele and genotype frequencies were similar between Miniature Schnauzers with and without a history of pancreatitis and did not impart an increased risk for pancreatitis. Genotyping a larger population of the Miniature Schnauzer breed than a previous study, along with a Standard Schnauzer cohort, demonstrated that the SPINK1 c.74A > C variant is a common polymorphism in the Schnauzer lineage. Furthermore, we were unable to confirm a relationship between the variant and clinically detectable pancreatitis in Miniature Schnauzers. Copyright © 2012 by the American College of Veterinary Internal Medicine.

  19. Effect of laser parameters on surface roughness of laser modified tool steel after thermal cyclic loading

    Science.gov (United States)

    Lau Sheng, Annie; Ismail, Izwan; Nur Aqida, Syarifah

    2018-03-01

    This study presents the effects of laser parameters on the surface roughness of laser modified tool steel after thermal cyclic loading. Pulse mode Nd:YAG laser was used to perform the laser surface modification process on AISI H13 tool steel samples. Samples were then treated with thermal cyclic loading experiments which involved alternate immersion in molten aluminium (800°C) and water (27°C) for 553 cycles. A full factorial design of experiment (DOE) was developed to perform the investigation. Factors for the DOE are the laser parameter namely overlap rate (η), pulse repetition frequency (f PRF) and peak power (Ppeak ) while the response is the surface roughness after thermal cyclic loading. Results indicate the surface roughness of the laser modified surface after thermal cyclic loading is significantly affected by laser parameter settings.

  20. Creep rupture properties under varying load/temperature conditions on a nickel-base heat-resistant alloy strengthened by boron addition

    International Nuclear Information System (INIS)

    Tsuji, Hirokazu; Nakajima, Hajime; Tanabe, Tatsuhiko.

    1993-09-01

    A series of constant load and temperature creep rupture tests and varying load and temperature creep rupture tests was carried out on Hastelloy XR whose boron content level is 60 mass ppm at 900 and 1000degC in order to examine the behavior of the alloy under varying load and temperature conditions. The life fraction rule completely fails in the prediction of the creep rupture life under varying load and temperature conditions though the rule shows good applicability for Hastelloy XR whose boron content level is below 10 mass ppm. The modified life fraction rule has been proposed based on the dependence of the creep rupture strength on the born content level of the alloy. The modified rule successfully predicts the creep rupture life under the test conditions from 1000degC to 900degC. The trend observed in the tests from 900degC to 1000degC can be qualitatively explained by the mechanism that the oxide film which is formed during the prior exposure to 900degC plays the role of the protective barrier against the boron dissipation into the environment. (author)

  1. Prediction of wax buildup in 24 inch cold, deep sea oil loading line

    Energy Technology Data Exchange (ETDEWEB)

    Asperger, R.G.; Sattler, R.E.; Tolonen, W.J.; Pitchford, A.C.

    1981-10-01

    When designing pipelines for cold environments, it is important to know how to predict potential problems due to wax deposition on the pipeline's inner surface. The goal of this work was to determine the rate of wax buildup and the maximum, equlibrium wax thickness for a North Sea field loading line. The experimental techniques and results used to evaluate the waxing potential of the crude oil (B) are described. Also, the theoretic model which was used for predicting the maximum wax deposit thickness in the crude oil (B) loading pipeline at controlled temperatures of 40 F (4.4 C) and 100 F (38 C), is illustrated. Included is a recommendation of a procedure for using hot oil at the end of a tanker loading period in order to dewax the crude oil (B) line. This technique would give maximum heating of the pipeline and should be followed by shutting the hot oil into the pipeline at the end of the loading cycle which will provide a hot oil soaking to help soften existing wax. 14 references.

  2. Scale up, optimization and stability analysis of Curcumin C3 complex-loaded nanoparticles for cancer therapy

    Science.gov (United States)

    2012-01-01

    Background Nanoparticle based delivery of anticancer drugs have been widely investigated. However, a very important process for Research & Development in any pharmaceutical industry is scaling nanoparticle formulation techniques so as to produce large batches for preclinical and clinical trials. This process is not only critical but also difficult as it involves various formulation parameters to be modulated all in the same process. Methods In our present study, we formulated curcumin loaded poly (lactic acid-co-glycolic acid) nanoparticles (PLGA-CURC). This improved the bioavailability of curcumin, a potent natural anticancer drug, making it suitable for cancer therapy. Post formulation, we optimized our process by Reponse Surface Methodology (RSM) using Central Composite Design (CCD) and scaled up the formulation process in four stages with final scale-up process yielding 5 g of curcumin loaded nanoparticles within the laboratory setup. The nanoparticles formed after scale-up process were characterized for particle size, drug loading and encapsulation efficiency, surface morphology, in vitro release kinetics and pharmacokinetics. Stability analysis and gamma sterilization were also carried out. Results Results revealed that that process scale-up is being mastered for elaboration to 5 g level. The mean nanoparticle size of the scaled up batch was found to be 158.5 ± 9.8 nm and the drug loading was determined to be 10.32 ± 1.4%. The in vitro release study illustrated a slow sustained release corresponding to 75% drug over a period of 10 days. The pharmacokinetic profile of PLGA-CURC in rats following i.v. administration showed two compartmental model with the area under the curve (AUC0-∞) being 6.139 mg/L h. Gamma sterilization showed no significant change in the particle size or drug loading of the nanoparticles. Stability analysis revealed long term physiochemical stability of the PLGA-CURC formulation. Conclusions A successful effort towards

  3. CFD-based design load analysis of 5MW offshore wind turbine

    Science.gov (United States)

    Tran, T. T.; Ryu, G. J.; Kim, Y. H.; Kim, D. H.

    2012-11-01

    The structure and aerodynamic loads acting on NREL 5MW reference wind turbine blade are calculated and analyzed based on advanced Computational Fluid Dynamics (CFD) and unsteady Blade Element Momentum (BEM). A detailed examination of the six force components has been carried out (three force components and three moment components). Structure load (gravity and inertia load) and aerodynamic load have been obtained by additional structural calculations (CFD or BEM, respectively,). In CFD method, the Reynolds Average Navier-Stokes approach was applied to solve the continuity equation of mass conservation and momentum balance so that the complex flow around wind turbines was modeled. Written in C programming language, a User Defined Function (UDF) code which defines transient velocity profile according to the Extreme Operating Gust condition was compiled into commercial FLUENT package. Furthermore, the unsteady BEM with 3D stall model has also adopted to investigate load components on wind turbine rotor. The present study introduces a comparison between advanced CFD and unsteady BEM for determining load on wind turbine rotor. Results indicate that there are good agreements between both present methods. It is importantly shown that six load components on wind turbine rotor is significant effect under Extreme Operating Gust (EOG) condition. Using advanced CFD and additional structural calculations, this study has succeeded to construct accuracy numerical methodology to estimate total load of wind turbine that compose of aerodynamic load and structure load.

  4. Damage process of high purity tungsten coatings by hydrogen beam heat loads

    International Nuclear Information System (INIS)

    Tamura, S.; Tokunaga, K.; Yoshida, N.; Taniguchi, M.; Ezato, K.; Sato, K.; Suzuki, S.; Akiba, M.; Tsunekawa, Y.; Okumiya, M.

    2005-01-01

    To investigate the synergistic effects of heat load and hydrogen irradiation, cyclic heat load tests with a hydrogen beam and a comparable electron beam were performed for high purity CVD-tungsten coatings. Surface modification was examined as a function of the peak temperature by changing the heat flux. Scanning Electron Microscopy analysis showed that the surface damage caused by the hydrogen beam was more severe than that by the electron beam. In the hydrogen beam case, cracking at the surface occurred at all peak temperatures examined from 300 deg. C to 1600 deg. C. These results indicate that the injected hydrogen induces embrittlement for the CVD-tungsten coating

  5. WIRELESS TECHNOLOGIES for LOCATION-BASED SERVICES

    Directory of Open Access Journals (Sweden)

    Dewi Wirastuti

    2012-06-01

    Full Text Available This paper presents an overview of wireless technologies that support location-based services (LBS. Satellite and cellular networks have exploited their communication infrastructure to offer LBS. The rapid deployment of mobile broadband wireless networks has offered another appealing application area. Key to the realisation of LBS is an efficient and accurate positioning technique with various methods and offering different performance levels. So far, Global Positioning System (GPS has offered the best accuracy at a low cost but it is challenged by poor indoor coverage. With the rapid deployment of broadband wireless access ubiquitously, Mobile WiMAX (Worldwide Interoperability for Microwave Access is seen as a potential positioning option for LBS. Some key features of WiMAX, i.e., broadband benefit, high speed and large coverage area; it will be exploited to provide LBS.

  6. Removal torque evaluation of three different abutment screws for single implant restorations after mechanical cyclic loading.

    Science.gov (United States)

    Paepoemsin, T; Reichart, P A; Chaijareenont, P; Strietzel, F P; Khongkhunthian, P

    2016-01-01

    The aim of this study was to evaluate the removal torque of three different abutment screws and pull out strength of implant-abutment connection for single implant restorations after mechanical cyclic loading. The study was performed in accordance with ISO 14801:2007. Three implant groups (n=15) were used: group A, PW Plus® with flat head screw; group B, PW Plus® with tapered screw; and group C, Conelog® with flat head screw. All groups had the same implant-abutment connection feature: cone with mandatory index. All screws were tightened with manufacturer's recommended torque. Ten specimens in each group underwent cyclic loading (1×106 cycles, 10 Hz, and 250 N). Then, all specimens were un-tightened, measured for the removal torque, and underwent a tensile test. The force that dislodged abutment from implant fixture was recorded. The data were analysed using independent sample t-test, ANOVA and Tukey HSD test. Before cyclic loading, removal torque in groups A, B and C were significantly different (B> A> C, Pabutment from implant fixture increased immensely after cyclic loading.

  7. Investigation programme and procedure for creep and long-term rupture strength in materials with accounting for stress deviator and loading history

    International Nuclear Information System (INIS)

    Mozharovskaya, T.N.

    1984-01-01

    A programme and procedure are given to study 08Kh18N9 steel at 600 deg C and 15Kh2MFA steel at 550 deg C for creep and long-term strength at different parameters of proportional loading as well as at different parameters under loading in two-link irregular trajectories. This makes it possible to estimate the effect of the kind of a stress deviator, history and prehistory of loading on plastic deformation in creep and on failure under long-term loading

  8. Investigation programme and procedure for creep and long-term rupture strength in materials with accounting for stress deviator and loading history

    Energy Technology Data Exchange (ETDEWEB)

    Mozharovskaya, T N [AN Ukrainskoj SSR, Kiev. Inst. Problem Prochnosti

    1984-11-01

    A programme and procedure are given to study 08Kh18N9 steel at 600 deg C and 15Kh2MFA steel at 550 deg C for creep and long-term strength at different parameters of proportional loading as well as at different parameters under loading in two-link irregular trajectories. This makes it possible to estimate the effect of the kind of a stress deviator, history and prehistory of loading on plastic deformation in creep and on failure under long-term loading.

  9. Mechanistic Studies of the Anti-Ulcerogenic Activity and Acute Toxicity Evaluation of Dichlorido-Copper(II-4-(2-5-Bromo-benzylideneaminoethyl Piperazin-1-ium Phenolate Complex against Ethanol-Induced Gastric Injury in Rats

    Directory of Open Access Journals (Sweden)

    A. Hamid A. Hadi

    2011-10-01

    Full Text Available The compound dichlorido-copper(II-4-(2-5-bromobenzylideneaminoethyl piperazin-1-ium phenolate (CuLBS was synthesized, characterized and screened for acute toxicity and protective activity against ethanol-induced gastric mucosal injury in rats. Gross microscopic lesions, biochemical and immunological parameters and histochemcial staining of glycogen storage were taken into consideration. Oral administration of CuLBS (30 and 60 mg/Kg for two weeks dose-dependently flattened gastric mucosa, significantly increased gastric mucus and total acidity, compared with control group (P < 0.01. Serum levels of liver enzymes aspartate (AST and alanine transaminases (ALT, pro-inflammatory (IL-6 and TNF-α and anti-inflammatory (IL-10 cytokines in the rats exposed to ethanol induced ulceration have been altered. Administration of CuLBS showed considerable (P < 0.05 protection against ulceration by modulating the acute alterations of cytokines AST, ALT and stomach glycogen. Interestingly, CuLBS did not interfere with the natural release of nitric oxide. CuLBS alone (60 mg/Kg did not exhibit any ulcerogenic effect as assessed using Adami’s scoring scale. An acute toxicity study showed that rats treated with CuLBS (1,000 and 2,000 mg/Kg manifested no abnormal signs. These findings therefore, suggested that the gastroprotective activity of CuLBS might contribute in modulating the inflammatory cytokine-mediated oxidative damage to gastric mucosa.

  10. Ad-hoc Network of Smart Sensors for Mechanical Load Measurement

    Directory of Open Access Journals (Sweden)

    Manuel A. Vieira

    2016-07-01

    Full Text Available Strain gauges load cells are transducers devices capable of converting changes in applied mechanical load into an electrical analog signal. Those devices have a large spectrum of applications ranging from domestic to industrial or even medical appliances just to name a few. In this work, they are used in the electronic instrumentation of a force platform that will be used to carry out the analysis and characterization of human biomechanical walking. In this platform, four load cells are installed, each one capable of measuring forces along two different axis. A total of eight strain-gauges per load cell are employed. Hence, analog signal transmission, besides requiring a large number of connection wires, is prone to interference and noise. Moreover, with this solution, scalability requires severe changes in the connection topology. In order to circumvent those problems, an alternative in-situ signal conditioning and digital data transmission system was devised. This approach, as far as investigated, presents an innovative solution to signal conditioning and data transmission for load-cells. In particular, the presented solution allows the creation of an ad-hoc network of load cells, using the I²C protocol with a master interface that allows the users to interact and change the parameters of each load cell. This instrumentation structure has been successfully tested and the obtained results are documented in this article.

  11. The unlubricated reciprocating sliding wear of 316 stainless steel in C02 in the temperature range 20 to 6000C

    International Nuclear Information System (INIS)

    Smith, A.F.

    1985-11-01

    The friction and wear behaviour of 316 stainless steel in C0 2 has been investigated in the load range 8 - 5ON from 20 to 600 0 C. Wear transitions occurred at all temperatures but were load dependent. At and below 300 0 C wear transitions only took place at low leads whereas above 300 0 C transitions were seen al all loads. The low temperature wear transition, giving an order of magnitude decrease in wear rate was associated with a change in friction behaviour. The friction force across the specimen was initially widely fluctuating and varied from cycle to cycle. After a time, which did not necessarily coincide with the wear transition the cyclic variation in the friction force become much less. This smoother sliding is thought to indicate a trend to oxide -oxide contacts. At higher temperatures wear transitions result in a two orders of magnitude reduction in wear. The corresponding friction transition was similar to the low temperature friction change but also included a marked temporary drop in the coefficient of friction. (author)

  12. Silicon-incorporated diamond-like coatings for Si3N4 mechanical seals

    International Nuclear Information System (INIS)

    Camargo, S.S.; Gomes, J.R.; Carrapichano, J.M.; Silva, R.F.; Achete, C.A.

    2005-01-01

    Amorphous silicon carbide (a-SiC) and silicon-incorporated diamond-like carbon films (DLC-Si) were evaluated as protective and friction reduction coatings onto Si 3 N 4 rings. Unlubricated tribological tests were performed with a pin-on-disk apparatus against stainless steel pins with loads ranging from 3 to 55 N and sliding velocities from 0.2 to 1.0 m/s under ambient air and 50-60% relative humidity. At the lowest loads, a-SiC coatings present a considerable improvement with respect to the behavior of uncoated disks since the friction coefficient is reduced to about 0.2 and the system is able to run stably for thousands of meters. At higher loads, however, a-SiC coatings fail. DLC-Si-coated rings, on the other hand, presented for loads up to 10 N a steady-state friction coefficient below 0.1 and very low wear rates. The lowest steady-state mean friction coefficient value of only 0.055 was obtained with a sliding velocity of 0.5 m/s. For higher loads in the range of 20 N, the friction coefficient drops to values around 0.1 but no steady state is reached. For the highest loads of over 50 N, a catastrophic behavior is observed. Typically, wear rates below 5x10 -6 and 2x10 -7 mm 3 /N m were obtained for the ceramic rings and pins, respectively, with a load of 10 N and a sliding velocity of 0.5 m/s. Analysis of the steel pin contact surface by scanning electron microscopy (SEM)-energy dispersive X-ray spectrometry (EDS) and Auger spectroscopy revealed the formation of an adherent tribo-layer mainly composed by Si, C and O. The unique structure of DLC-Si films is thought to be responsible for the formation of the tribo-layer

  13. Thermoluminescence of annealed and shock-loaded feldspar

    International Nuclear Information System (INIS)

    Hartmetz, C.P.

    1988-01-01

    Samples of oligoclase and bytownite were shock-loaded to a variety of pressures, and annealed for a variety of temperatures and times. The effect of Mrad doses of gamma-rays on oligoclase TL were also studied. After these treatments, thermoluminescence (TL) and X-ray diffraction (XRD) measurements were made to: (1) determine the effects of shock on terrestrial feldspar and compare with variations in the TL emission of ordinary chondrites (OCs); (2) determine if disordering in feldspar was responsible for any related changes in TL properties of OCs; (3) determine if the combined effect of shock plus annealing causes the changes in TL properties; (4) see if radiation damage from cosmic ray exposure plays a role in the TL variations; (5) examine the implications of this work to the thermal and shock histories of OCs. The lightly shock-loaded and annealed oligoclase samples have a dominant peak temperature of 120-140 C, identical to type 3.3-3.5 OCs. The heavily shocked samples dominant peak is at 230C, similar to type > 3.5 OCs . While the heavily annealed/disordered oligoclase samples have a peak at 280C, this peak is rarely observed in OCs. Radiation damage from Mrad doses of gamma-rays produced no change in peak temperature, but facilitated the shift to higher peak temperatures. The TL sensitivity of the shocked samples decreased by a factor of 25. Samples annealed at low temperatures (438-533C) showed a factor of 2 decrease in TL, but at the highest temperatures, the TL was a factor of 8 higher

  14. Load-dependent surface diffusion model for analyzing the kinetics of protein adsorption onto mesoporous materials.

    Science.gov (United States)

    Marbán, Gregorio; Ramírez-Montoya, Luis A; García, Héctor; Menéndez, J Ángel; Arenillas, Ana; Montes-Morán, Miguel A

    2018-02-01

    The adsorption of cytochrome c in water onto organic and carbon xerogels with narrow pore size distributions has been studied by carrying out transient and equilibrium batch adsorption experiments. It was found that equilibrium adsorption exhibits a quasi-Langmuirian behavior (a g coefficient in the Redlich-Peterson isotherms of over 0.95) involving the formation of a monolayer of cyt c with a depth of ∼4nm on the surface of all xerogels for a packing density of the protein inside the pores of 0.29gcm -3 . A load-dependent surface diffusion model (LDSDM) has been developed and numerically solved to fit the experimental kinetic adsorption curves. The results of the LDSDM show better fittings than the standard homogeneous surface diffusion model. The value of the external mass transfer coefficient obtained by numerical optimization confirms that the process is controlled by the intraparticle surface diffusion of cyt c. The surface diffusion coefficients decrease with increasing protein load down to zero for the maximum possible load. The decrease is steeper in the case of the xerogels with the smallest average pore diameter (∼15nm), the limit at which the zero-load diffusion coefficient of cyt c also begins to be negatively affected by interactions with the opposite wall of the pore. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. The effects of loading history on fatigue crack growth threshold

    International Nuclear Information System (INIS)

    Ogawa, Takeshi; Tokaji, Keiro; Ochi, Satoshi; Kobayashi, Hideo.

    1987-01-01

    The effects of loading history on threshold stress intensity range (ΔK th ) were investigated in a low alloy steel SFVQ1A (A508 - 3) and a low carbon steel S10C. A single overload and multiple overloads were chosen as loading history. Crack growth and crack closure following the loading histories were measured at load ratios of 0.05 and 0.70. Threshold values were determined as a fatigue limit of preloaded specimens. The ΔK th values increased with increasing overload stress intensity factor (K h ). For a given K h value, multiple overloads produced much larger increase in ΔK th than a single overload and threshold values expressed by maximum stress intensity factor (K max,th ) were almost constant, independent of stress ratio. The results obtained were discussed in terms of crack closure behaviour, and a method was proposed to evaluate the threshold value based on plasticity-induced crack closure. (author)

  16. Load forecasting

    International Nuclear Information System (INIS)

    Mak, H.

    1995-01-01

    Slides used in a presentation at The Power of Change Conference in Vancouver, BC in April 1995 about the changing needs for load forecasting were presented. Technological innovations and population increase were said to be the prime driving forces behind the changing needs in load forecasting. Structural changes, market place changes, electricity supply planning changes, and changes in planning objectives were other factors discussed. It was concluded that load forecasting was a form of information gathering, that provided important market intelligence

  17. Socket weld integrity in nuclear piping under fatigue loading condition

    International Nuclear Information System (INIS)

    Choi, Young Hwan; Choi, Sun Yeong

    2007-01-01

    The purpose of this paper is to evaluate the integrity of socket weld in nuclear piping under the fatigue loading. The integrity of socket weld is regarded as a safety concern in nuclear power plants because many failures have been world-widely reported in the socket weld. Recently, socket weld failures in the chemical and volume control system (CVCS) and the primary sampling system (PSS) were reported in Korean nuclear power plants. The root causes of the socket weld failures were known as the fatigue due to the pressure and/or temperature loading transients and the vibration during the plant operation. The ASME boiler and pressure vessel (B and PV) Code Sec. III requires 1/16 in. gap between the pipe and fitting in the socket weld with the weld leg size of 1.09 x t 1 , where t 1 is the pipe wall thickness. Many failure cases, however, showed that the gap requirement was not satisfied. In addition, industry has demanded the reduction of weld leg size from 1.09 x t 1 to 0.75 x t 1 . In this paper, the socket weld integrity under the fatigue loading was evaluated using three-dimensional finite element analysis considering the requirements in the ASME Code. Three types of loading conditions such as the deflection due to vibration, the pressure transient ranging from P = 0 to 15.51 MPa, and the thermal transient ranging from T = 25 to 288 deg. C were considered. The results are as follows; (1) the socket weld is susceptible to the vibration where the vibration levels exceed the requirement in the ASME operation and maintenance (OM) code. (2) The effect of pressure or temperature transient load on socket weld in CVCS and PSS is not significant owing to the low frequency of transient during plant operation. (3) 'No gap' is very risky to the socket weld integrity for the systems having the vibration condition to exceed the requirement specified in the ASME OM Code and/or the transient loading condition from P = 0 and T = 25 deg. C to P = 15.51 MPa and T = 288 deg. C. (4

  18. Wind Loads on Structures

    DEFF Research Database (Denmark)

    Dyrbye, Claes; Hansen, Svend Ole

    Wind loads have to be taken into account when designing civil engineering structures. The wind load on structures can be systematised by means of the wind load chain: wind climate (global), terrain (wind at low height), aerodynamic response (wind load to pressure), mechanical response (wind...... pressure to structural response) and design criteria. Starting with an introduction of the wind load chain, the book moves on to meteorological considerations, atmospheric boundary layer, static wind load, dynamic wind load and scaling laws used in wind-tunnel tests. The dynamic wind load covers vibrations...... induced by wind turbulence, vortex shedding, flutter and galloping. The book gives a comprehensive treatment of wind effects on structures and it will be useful for consulting engineers designing wind-sensitive structures. It will also be valuable for students of civil engineering as textbook...

  19. Limit load assessment of centre cracked plates under biaxial loading

    International Nuclear Information System (INIS)

    Meek, C.; Ainsworth, R.A.

    2015-01-01

    Fitness-for-service of equipment and components containing defects is generally assessed using procedures such as BS 7910, API 579 and R6. There is currently little detailed advice in these procedures on the effects of biaxial and triaxial loading on fracture. This poster shows some theoretical bounding solutions of the plastic limit load for centre cracked plates under a variety of biaxial loading ratios and compares the estimates with those found by numerical methods using finite element (FE) analysis using Abacus CAE modelling software. The limit load of a structure is the maximum load that it can carry before plastic collapse occurs; this is often when the plastic zone has become large enough to spread from the crack tip to a remote boundary. For an elastic-perfectly plastic material, the irreversible deformation will continue at stresses no higher than the yield stress. The model for these limit load solutions is a bi-axially loaded plate of width 2W and height 2H, a centre crack of width 2a, acted on by remotely applied uniform stresses σ 2 perpendicular to the crack and Bσ 2 parallel to the crack, where B is the biaxial loading ratio, it means the ratio of the parallel to the perpendicular stress. A quarter plate of an elastic-perfectly plastic material has been modelled. The results show that an exact solution has been found for negative and low positive values of B. For B > 1, the lower bound solution is conservative for all values of a/W and B

  20. Peptide-loaded dendritic cells prime and activate MHC-class I-restricted T cells more efficiently than protein-loaded cross-presenting DC

    DEFF Research Database (Denmark)

    Met, Ozcan; Buus, Søren; Claesson, Mogens H

    2003-01-01

    -pulsed DC. Moreover, SIINFEKL-loaded DC were up to 50 times more efficient than DC-pulsed with OVA-protein for generation of an H-2K(b)-restricted response. Immunization of mice with SIINFEKL-loaded DC resulted in a much stronger H-2K(b)-restricted response than immunization with OVA-pulsed DC. These data......Undifferentiated and differentiated dendritic cells (uDC and dDC, respectively), derived from the bone marrow, were studied in vitro and in vivo. Ovalbumin (OVA) and two OVA-derived peptides binding to H-2K(b) and I-A(b), respectively, were used. Two IL-2 secreting T cell hybridomas specific...... for the OVA-derived epitopes were used in the in vitro read-out. The ability to cross-present the H-2K(b) binding OVA(257-264)-peptide (SIINFEKL) was restricted to dDC, which express CD11c(+), CD86(+), and MHC-II(+). In vitro, the antigenicity of SIINFEKL-loaded DC declined at a slower rate than that of OVA...

  1. Torque and Axial Loading Physics for Measuring Atmospheric Icing Load and Icing Rate

    OpenAIRE

    Mughal, Umair Najeeb; Virk, Muhammad Shakeel

    2015-01-01

    Measuring icing load and icing rate are important parameters for an atmospheric icing sensor. A new icing sensor has recently been designed and developed at Narvik University College for measuring atmospheric icing rate, icing load and icing type. Unlike the existing atmospheric icing sensors commercially available in market, which uses the axial loading for measuring icing load and icing rate, this new sensory system measures icing load and icing rate using the torque loading physics. The pe...

  2. Development of an in vitro three dimensional loading-measurement system for long bone fixation under multiple loading conditions: a technical description

    Directory of Open Access Journals (Sweden)

    Wilson David A

    2007-11-01

    Full Text Available Abstract The purpose of this investigation was to design and verify the capabilities of an in vitro loading-measurement system that mimics in vivo unconstrained three dimensional (3D relative motion between long bone ends, applies uniform load components over the entire length of a test specimen, and measures 3D relative motion between test segment ends to directly determine test segment construct stiffness free of errors due to potting-fixture-test machine finite stiffness. Intact equine cadaveric radius bones, which were subsequently osteotomized/ostectomized and instrumented with bone plates were subjected to non-destructive axial, torsion, and 4-point bending loads through fixtures designed to allow unconstrained components of non-load associated 3D relative motion between radius ends. 3D relative motion between ends of a 50 mm long test segment was measured by an infrared optical tracking system to directly determine its stiffness. Each specimen was then loaded to ultimate failure in either torsion or bending. Cortical bone cross-section diameters and published bone biomechanical properties were substituted into classical mechanics equations to predict the intact test segment theoretical stiffness for comparison and thus loading-measurement system verification. Intact measured stiffness values were the same order of magnitude as theoretically predicted. The primary component of relative motion between ends of the test segment corresponded to that of the applied load with the other 3D components being evident and consistent in relative magnitude and direction for unconstrained loading of an unsymmetrical double plate oblique fracture configuration. Bone failure configurations were reproducible and consistent with theoretically predicted. The 3D loading-measurement system designed: a mimics unconstrained relative 3D motion between radius ends that occurs in clinical situations, b applies uniform compression, torsion, and 4-point bending loads

  3. Low-back loading in lifting two loads beside the body compared to lifting one load in front of the body

    NARCIS (Netherlands)

    Faber, G.S.; Kingma, I.; Bakker, A.J.; van Dieen, J.H.

    2009-01-01

    Low-back load during manual lifting is considered an important risk factor for the occurrence of low-back pain. Splitting a load, so it can be lifted beside the body (one load in each hand), instead of in front of the body, can be expected to reduce low-back load. Twelve healthy young men lifted 10

  4. Probabilistic Load Models for Simulating the Impact of Load Management

    DEFF Research Database (Denmark)

    Chen, Peiyuan; Bak-Jensen, Birgitte; Chen, Zhe

    2009-01-01

    . It is concluded that the AR(12) model is favored with limited measurement data and that the joint-normal model may provide better results with a large data set. Both models can be applied in general to model load time series and used in time-sequential simulation of distribution system planning.......This paper analyzes a distribution system load time series through autocorrelation coefficient, power spectral density, probabilistic distribution and quantile value. Two probabilistic load models, i.e. the joint-normal model and the autoregressive model of order 12 (AR(12)), are proposed...... to simulate the impact of load management. The joint-normal model is superior in modeling the tail region of the hourly load distribution and implementing the change of hourly standard deviation. Whereas the AR(12) model requires much less parameter and is superior in modeling the autocorrelation...

  5. Concurrent Working Memory Load Can Facilitate Selective Attention: Evidence for Specialized Load

    Science.gov (United States)

    Park, Soojin; Kim, Min-Shik; Chun, Marvin M.

    2007-01-01

    Load theory predicts that concurrent working memory load impairs selective attention and increases distractor interference (N. Lavie, A. Hirst, J. W. de Fockert, & E. Viding, see record 2004-17825-003). Here, the authors present new evidence that the type of concurrent working memory load determines whether load impairs selective attention or not.…

  6. Behavior and ultimate strength of an inner concrete structure of a nuclear reactor building subjected to thermal and seismic loads

    International Nuclear Information System (INIS)

    Omatsuzawa, K.; Suzuki, Y.; Sato, M.; Takeda, T.; Yamaguchi, T.; Yoshioka, K.; Nakayama, T.; Furuya, N.; Kawaguchi, T.; Koike, K.; Naganuma, K.

    1987-01-01

    Heating tests and heating-plus-seismic-loading tests at high temperature (T max = 175 0 C) were conducted using various concrete structural members such as beams, cylindrical walls, H-section walls, and 1/10-scale models of the inner concrete (I/C) structure in a fast breeder reactor (FBR) building. Concrete subjected to high temperature exceeding 100 0 C has a tendency to have lower Young's modulus and to shrink. As these material constants are temperature-dependent, the thermal stress occurring within the concrete structure is smaller than the values usually obtained by normal crack analysis methods. Although thermal stresses and cracks exert marked influences on the behaviors of the structures during the earlier stages of loading, they hardly affect the ultimate bending and shear strengths. Specifically, as a result of I/C model tests, it was made clear that the ultimate strength of the structure is considerably greater than the design loads under combined thermal and seismic loading conditions. (orig./HP)

  7. Titanium tritide radioisotope heat source development: palladium-coated titanium hydriding kinetics and tritium loading tests

    International Nuclear Information System (INIS)

    Van Blarigan, Peter; Shugard, Andrew D.; Walters, R. Tom

    2012-01-01

    We have found that a 180 nm palladium coating enables titanium to be loaded with hydrogen isotopes without the typical 400-500 C vacuum activation step. The hydriding kinetics of Pd coated Ti can be described by the Mintz-Bloch adherent film model, where the rate of hydrogen absorption is controlled by diffusion through an adherent metal-hydride layer. Hydriding rate constants of Pd coated and vacuum activated Ti were found to be very similar. In addition, deuterium/tritium loading experiments were done on stacks of Pd coated Ti foil in a representative-size radioisotope heat source vessel. The experiments demonstrated that such a vessel could be loaded completely, at temperatures below 300 C, in less than 10 hours, using existing department-of-energy tritium handling infrastructure.

  8. Loading and release of doxorubicin with magnetic nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Bai, Xia; Wang, Xiang; Lee, Sang Bok [Dept. of Chemistry and Biochemistry, University of Maryland, College Park (United States); English, Douglas [Dept. of Chemistry, Wichita State University, Wichita (United States)

    2015-03-15

    In this work, we study magnetic nanotubes (MNTs) as drug carriers to control the loading and release of doxorubicin (Dox). The inner surfaces of MNTs where Dox molecules are stored are modified with C18-silane and pyridine–silane. By tuning the interaction between the drug molecules and inner surfaces of MNTs via pH, Dox can be effectively encapsulated at pH 7.2 and released at pH 4.5. The successful loading of Dox is confirmed with confocal microscopy studies. The release profiles of Dox from modified MNTs are detected by spectrofluorophotometry, with bare MNTs as control. With proper modifications, MNTs can be used for pH-dependent, controlled release of drug molecules.

  9. The duration perception of loading applications in smartphone: Effects of different loading types.

    Science.gov (United States)

    Zhao, Wenguo; Ge, Yan; Qu, Weina; Zhang, Kan; Sun, Xianghong

    2017-11-01

    The loading time of a smartphone application is an important issue, which affects the satisfaction of phone users. This study evaluated the effects of black loading screen (BLS) and animation loading screen (ALS) during application loading on users' duration perception and satisfaction. A total of 43 volunteers were enrolled. They were asked to complete several tasks by clicking the icons of each application, such as camera or message. The duration of loading time for each application was manipulated. The participants were asked to estimate the duration, evaluate the loading speed and their satisfaction. The results showed that the estimated duration increased and the satisfaction for loading period declined along with the loading time increased. Compared with the BLS, the ALS prolonged the estimated duration, and lowered the evaluation of speed and satisfaction. We also discussed the tendency and key inflection points of the curves involving the estimated duration, speed evaluation and satisfaction with the loading time. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Influence of cracks generation on the structural and optical properties of GaN/Al0.55Ga0.45N multiple quantum wells

    International Nuclear Information System (INIS)

    Sun, Q.; Zhang, J.C.; Huang, Y.; Chen, J.; Wang, J.F.; Wang, H.; Li, D.Y.; Wang, Y.T.; Zhang, S.M.; Yang, H.; Zhou, C.L.; Guo, L.P.; Jia, Q.J.

    2006-01-01

    Both cracked and crack-free GaN/Al 0.55 Ga 0.45 N multiple quantum wells (MQWs) grown on GaN template by metalorganic chemical vapor deposition have been studied by triple-axis X-ray diffraction, grazing-incidence X-ray reflectivity, atomic force microscope, photoluminescence spectroscopy and low-energy positron annihilation spectroscopy. The experimental results show that cracks generation not only deteriorates the surface morphology, but also leads to a period dispersion and roughens the interfaces of MQWs. The mean density of dislocations in MQWs, determined from the average full-width at half-maximum of ω-scan of each satellite peak, has been significantly enhanced by the cracks generation. Furthermore, the measurement of annihilation-line Doppler broadening reveals a higher concentration of negatively charged vacancies in the cracked MQWs. The combination of these vacancies and the high density of edge dislocations are assumed to contribute to the highly enhanced yellow luminescence in the cracked sample

  11. LOAD ON BURIED PRESSURE CONDUITS WITH REFERENCE TO ...

    African Journals Online (AJOL)

    width of conduit or trench; the shearing forces on the plane between the backfill and adjacent earth; for embankment condition, the amounL of relative settlement between the backfill and adjacent earth; the rigidity of the conduit support under embankment loading. Table 3. Selected values of c'' for use in Eq. 8. Sand and.

  12. Study of failure criterion applicable to elastic-plastic finite element analyses of wall-thinned pipes subjected to multi-axial loading. Case for groove type flaw under combined internal pressure and bending loading

    International Nuclear Information System (INIS)

    Mori, Kosuke; Meshii, Toshiyuki

    2015-01-01

    In this paper, a failure criterion applicable to large-strain finite element analysis (FEA) results was studied to predict the limit bending load M_c of the groove shaped wall-thinned pipes, under combined internal pressure and bending load, that experienced cracking. In our previous studies, Meshii and Ito (2012) considered cracking of pipes with groove shaped flaw (small axial length δ_z in Fig. 1) was due to the plastic instability at the wall-thinned section and proposed the Domain Collapse Criterion (DCC). The DCC could predict M_c of cracking for small δ_z by comparing the von Mises stress σ_M_i_s_e_s with the true tensile strength σ_B. Because the discrepancy in prediction of the M_c in the case of cracking was within 15%, it was considered that the predictability was could be improved further. Thus, in this work, attempt was made to improve the accuracy of M_c prediction with a perspective that multi-axial stress state might affect this plastic instability at the wall-thinned section. As a result of examination of the various failure criteria based on multi-axial stress, it was confirmed that the limit bending load of the groove flawed pipe that experienced cracking in experiment (Hereafter, it was expressed 'flawed pipe that experienced cracking') could be predicted within 5% accuracy by applying Hill's plastic instability onset criterion (Hill, 1952) to the outer surface of the crack penetration section. The accuracy of the predicted limit bending load was improved from DCC's within 15% to within 5%. (author)

  13. The effects of autonomous learning on cognitive load and learning results

    NARCIS (Netherlands)

    Gorissen, Chantal; Kester, Liesbeth; Brand-Gruwel, Saskia; Martens, Rob

    2012-01-01

    Gorissen, C. J. J., Kester, L., Brand-Gruwel, S., & Martens, R. L. (2011, August). The Effects of Autonomous Learning on Cognitive Load and Learning Results. Presentation at the EARLI conference. Exeter, UK.

  14. Effects of moisture, elevated temperature, and fatigue loading on the behavior of graphite/epoxy buffer strip panels with center cracks

    Science.gov (United States)

    Bigelow, C. A.

    1988-01-01

    The effects of fatigue loading combined with moisture and heat on the behavior of graphite epoxy panels with either Kevlar-49 or S-glass buffer strips were studied. Buffer strip panels, that had a slit in the center to represent damage, were moisture conditioned or heated, fatigue loaded, and then tested in tension to measure their residual strength. The buffer strips were parallel to the loading direction and were made by replacing narrow strips of the 0 deg graphite plies with Kevlar-49 epoxy or S-glass epoxy on a 1-for-1 basis. The panels were subjected to a fatigue loading spectrum. One group of panels was preconditioned by soaking in 60 C water to produce a 1 percent weight gain then tested at room temperature. One group was heated to 82 C during the fatigue loading. Another group was moisture conditioned and then tested at 82 C. The residual strengths of the buffer panels were not highly affected by the fatigue loading, the number of repetitions of the loading spectrum, or the maximum strain level. The moisture conditioning reduced the residual strengths of the S-glass buffer strip panel by 10 to 15 percent below the ambient results. The moisture conditioning did not have a large effect on the Kevlar-49 panels.

  15. Electrical load modeling

    Energy Technology Data Exchange (ETDEWEB)

    Valgas, Helio Moreira; Pinto, Roberto del Giudice R.; Franca, Carlos [Companhia Energetica de Minas Gerais (CEMIG), Belo Horizonte, MG (Brazil); Lambert-Torres, Germano; Silva, Alexandre P. Alves da; Pires, Robson Celso; Costa, Junior, Roberto Affonso [Escola Federal de Engenharia de Itajuba, MG (Brazil)

    1994-12-31

    Accurate dynamic load models allow more precise calculations of power system controls and stability limits, which are critical mainly in the operation planning of power systems. This paper describes the development of a computer program (software) for static and dynamic load model studies using the measurement approach for the CEMIG system. Two dynamic load model structures are developed and tested. A procedure for applying a set of measured data from an on-line transient recording system to develop load models is described. (author) 6 refs., 17 figs.

  16. Biomechanical evaluation of an integrated fixation cage during fatigue loading: a human cadaver study.

    Science.gov (United States)

    Palepu, Vivek; Peck, Jonathan H; Simon, David D; Helgeson, Melvin D; Nagaraja, Srinidhi

    2017-04-01

    OBJECTIVE Lumbar cages with integrated fixation screws offer a low-profile alternative to a standard cage with anterior supplemental fixation. However, the mechanical stability of integrated fixation cages (IFCs) compared with a cage with anterior plate fixation under fatigue loading has not been investigated. The purpose of this study was to compare the biomechanical stability of a screw-based IFC with a standard cage coupled with that of an anterior plate under fatigue loading. METHODS Eighteen functional spinal units were implanted with either a 4-screw IFC or an anterior plate and cage (AP+C) without integrated fixation. Flexibility testing was conducted in flexion-extension (FE), lateral bending (LB), and axial rotation (AR) on intact spines, immediately after device implantation, and post-fatigue up to 20,000 cycles of FE loading. Stability parameters such as range of motion (ROM) and lax zone (LZ) for each loading mode were compared between the 2 constructs at multiple stages of testing. In addition, construct loosening was quantified by subtracting post-instrumentation ROM from post-fatigue ROM. RESULTS IFC and AP+C configurations exhibited similar stability (ROM and LZ) at every stage of testing in FE (p ≥ 0.33) and LB (p ≥ 0.23) motions. In AR, however, IFCs had decreased ROM compared with AP+C constructs at pre-fatigue (p = 0.07) and at all post-fatigue time points (p ≤ 0.05). LZ followed a trend similar to that of ROM in AR. ROM increased toward intact motion during fatigue cycling for AP+C and IFC implants. IFC specimens remained significantly (p < 0.01) more rigid than specimens in the intact condition during fatigue for each loading mode, whereas AP+C construct motion did not differ significantly (p ≥ 0.37) in FE and LB and was significantly greater (p < 0.01) in AR motion compared with intact specimens after fatigue. Weak to moderate correlations (R 2 ≤ 56%) were observed between T-scores and construct loosening, with lower T

  17. Transfection Agent Induced Nanoparticle Cell Loading

    Directory of Open Access Journals (Sweden)

    Karin Montet-Abou

    2005-07-01

    Full Text Available Loading cells with magnetic nanoparticles, and tracking their fate in vivo by high resolution MRI, is an attractive approach for enhancing the efficacy of cell-based therapies including those utilizing hematopoietic stem cells, neuroprogenitor cells, and T cells. The transfection agent (internalization agent assisted loading with the Feridex IV® nanoparticle is an attractive method of loading because of the low cost of materials, and possible low regulatory barriers for eventual clinical use. We therefore explored the interaction between Feridex IV® and three internalization agents protamine (PRO, polylysine (PLL, and lipofectamine (LFA. Feridex reacted with internalization agents to form aggregates, except when either the internalization agent or Feridex was present in large excess. When Jurkat T cells were incubated with Feridex/LFA or Feridex/PRO mixtures, and washed by centrifugation, nanoparticle aggregates co-purified with cells. With C17.2 cells large iron oxide particles adhered to the cell surface. At 30 μg/mL Feridex and 3 μg/mL LFA, internalization was largely mediated by LFA and was largely cytoplasmic. However, we found that the conditions used to label cells with Feridex and transfection agents need to be carefully selected to avoid the problems of surface adsorption and nanoparticle precipitation.

  18. Part-load performance of a high temperature Kalina cycle

    International Nuclear Information System (INIS)

    Modi, Anish; Andreasen, Jesper Graa; Kærn, Martin Ryhl; Haglind, Fredrik

    2015-01-01

    Highlights: • Detailed algorithm to solve high temperature Kalina cycle in part load. • A central receiver concentrating solar power plant with direct vapour generation considered as case study. • Part-load performance curves and fitted equations presented. - Abstract: The Kalina cycle has recently seen increased interest as an alternative to the conventional steam Rankine cycle. The cycle has been studied for use with both low and high temperature applications such as geothermal power plants, ocean thermal energy conversion, waste heat recovery, gas turbine bottoming cycle, and solar power plants. The high temperature cycle layouts are inherently more complex than the low temperature layouts due to the presence of a distillation-condensation subsystem, three pressure levels, and several heat exchangers. This paper presents a detailed approach to solve the Kalina cycle in part-load operating conditions for high temperature (a turbine inlet temperature of 500 °C) and high pressure (100 bar) applications. A central receiver concentrating solar power plant with direct vapour generation is considered as a case study where the part-load conditions are simulated by changing the solar heat input to the receiver. Compared with the steam Rankine cycle, the Kalina cycle has an additional degree of freedom in terms of the ammonia mass fraction which can be varied in order to maximize the part-load efficiency of the cycle. The results include the part-load curves for various turbine inlet ammonia mass fractions and the fitted equations for these curves.

  19. Creep rupture properties under varying load/temperature conditions on a nickel-base heat-resistant alloy strengthened by boron addition

    International Nuclear Information System (INIS)

    Tsuji, Hirokazu; Tanabe, Tatsuhiko; Nakajima, Hajime

    1994-01-01

    A series of constant load and temperature creep rupture tests and varying load and temperature creep rupture tests was carried out on Hastelloy XR whose boron content level is 60 mass ppm at 900 and 1000 C in order to examine the behavior of the alloy under varying load and temperature conditions. The life fraction rule completely fails in the prediction of the creep rupture life under varying load and temperature conditions though the rule shows good applicability for Hastelloy XR whose boron content level is below 10 mass ppm. The modified life fraction rule has been proposed based on the dependence of the creep rupture strength on the boron content level of the alloy. The modified rule successfully predicts the creep rupture life under the test conditions from 1000 to 900 C. The trend observed in the tests from 900 to 1000 C can be qualitatively explained by the mechanism that the oxide film which is formed during the prior exposure to 900 C plays the role of the protective barrier against the boron dissipation into the environment. (orig.)

  20. Macrophages loaded with gold nanoshells for photothermal ablation of glioma: An in vitro model

    Science.gov (United States)

    Makkouk, Amani Riad

    The current median survival of patients with glioblastoma multiforme (GBM), the most common type of glioma, remains at 14.6 months despite multimodal treatments (surgery, radiotherapy and chemotherapy). This research aims to study the feasibility of photothermal ablation of glioma using gold nanoshells that are heated upon laser irradiation at their resonance wavelength. The novelty of our approach lies in improving nanoshell tumor delivery by loading them in macrophages, which are known to be recruited to gliomas via tumor-released chemoattractive agents. Ferumoxides, superparamagnetic iron oxide (SPIO) nanoparticles, are needed as an additional macrophage load in order to visualize macrophage accumulation in the tumor with magnetic resonance imaging (MRI) prior to laser irradiation. The feasibility of this approach was studied in an in vitro model of glioma spheroids with the use of continuous wave (CW) laser light for ablation. The optimal loading of both murine and rat macrophages with Ferumoxides was determined using inductively coupled plasma atomic emission spectroscopy (ICP-AES). Higher concentrations of SPIO were observed in rat macrophages, and the optimal concentration was chosen at 100 microg Fe/ml. Macrophages were found to be very sensitive to near infra-red (NIR) laser irradiation, and their use as vehicles was thus not expected to hinder the function of loaded nanoshells as tumor-ablating tools. The intracellular presence of gold nanoshells in macrophages was confirmed with TEM imaging. Next, the loading of both murine and rat macrophages with gold nanoshells was studied using UV/Vis spectrophotometry, where higher nanoshell uptake was found in rat macrophages. Incubation of loaded murine and rat macrophages with rat C-6 and human ACBT spheroids, respectively, resulted in their infiltration of the spheroids. Subsequent laser irradiation at 55 W/cm2 for 10 min and follow-up of spheroid average diameter size over 14 days post-irradiation showed that

  1. Eugenol-loaded chitosan nanoparticles: II. Application in bio-based plastics for active packaging.

    Science.gov (United States)

    Woranuch, Sarekha; Yoksan, Rangrong

    2013-07-25

    The aim of the present research was to study the possibility of using eugenol-loaded chitosan nanoparticles as antioxidants for active bio-based packaging material. Eugenol-loaded chitosan nanoparticles were incorporated into thermoplastic flour (TPF) - a model bio-based plastic - through an extrusion process at temperatures above 150°C. The influences of eugenol-loaded chitosan nanoparticles on crystallinity, morphology, thermal properties, radical scavenging activity, reducing power, tensile properties and barrier properties of TPF were investigated. Although the incorporation of 3% (w/w) of eugenol-loaded chitosan nanoparticles significantly reduced the extensibility and the oxygen barrier property of TPF, it provided antioxidant activity and improved the water vapor barrier property. In addition, TPF containing eugenol-loaded chitosan nanoparticles exhibited superior radical scavenging activity and stronger reducing power compared with TPF containing naked eugenol. The results suggest the applicability of TPF containing eugenol-loaded chitosan nanoparticles as an antioxidant active packaging material. Copyright © 2012 Elsevier Ltd. All rights reserved.

  2. Blinded comparison of faecal loading on plain radiography versus radio-opaque marker transit studies in the assessment of constipation

    Energy Technology Data Exchange (ETDEWEB)

    Cowlam, S. [Sunderland Royal Hospital, Sunderland (United Kingdom); Vinayagam, R.; Khan, U.; Marsden, S.; Minty, I.; Moncur, P.; Bain, I. [University Hospital of North Durham, Durham (United Kingdom); Yiannakou, Y.J. [University Hospital of North Durham, Durham (United Kingdom)], E-mail: yan.yiannakou@cddft.nhs.uk

    2008-12-15

    Aim: To compare faecal loading on plain radiography versus radio-opaque marker transit studies in the assessment of constipation. Methods: The study group was a convenience sample of patients attending the Durham Constipation Clinic. All patients underwent transit studies according to an established protocol, and severity of constipation was assessed contemporaneously using a validated questionnaire (PAC-SYM). Transit studies were performed using radio-opaque markers that were ingested over 3 consecutive days, with a radiograph taken on the fourth day. Digital images of the radiograph were digitally altered to remove all traces of the transit markers without affecting the underlying pattern of faecal loading. Four observers assessed faecal loading independently; two clinicians (C1 and C2) and two radiologists (R1 and R2). C1 and R1 used a previously described formal scoring method of assessing faecal loading, whereas C2 and R2 assessed the images as if they were in a clinic or reporting session, grading the faecal loading as mild, moderate, or severe. Results: One hundred patients were recruited out of 186 presenting in a 2-year period. All patients completed assessments. The correlation between observers was only fair to moderate (r ranging from 0.34-0.51). There were some surprisingly marked disagreements in 10-18% of assessments. The correlation between faecal loading and transit was weak for all observers (r ranging from 0.261-0.311). Symptom severity did not correlate with faecal loading. Conclusion: These results suggest that there is considerable inter-observer variation in the radiological assessment of faecal loading, irrespective of the training or method used by the observer, and that there is very poor correlation with colonic transit. The diagnosis of constipation, and the assessment of severity, is best performed clinically.

  3. Blinded comparison of faecal loading on plain radiography versus radio-opaque marker transit studies in the assessment of constipation

    International Nuclear Information System (INIS)

    Cowlam, S.; Vinayagam, R.; Khan, U.; Marsden, S.; Minty, I.; Moncur, P.; Bain, I.; Yiannakou, Y.J.

    2008-01-01

    Aim: To compare faecal loading on plain radiography versus radio-opaque marker transit studies in the assessment of constipation. Methods: The study group was a convenience sample of patients attending the Durham Constipation Clinic. All patients underwent transit studies according to an established protocol, and severity of constipation was assessed contemporaneously using a validated questionnaire (PAC-SYM). Transit studies were performed using radio-opaque markers that were ingested over 3 consecutive days, with a radiograph taken on the fourth day. Digital images of the radiograph were digitally altered to remove all traces of the transit markers without affecting the underlying pattern of faecal loading. Four observers assessed faecal loading independently; two clinicians (C1 and C2) and two radiologists (R1 and R2). C1 and R1 used a previously described formal scoring method of assessing faecal loading, whereas C2 and R2 assessed the images as if they were in a clinic or reporting session, grading the faecal loading as mild, moderate, or severe. Results: One hundred patients were recruited out of 186 presenting in a 2-year period. All patients completed assessments. The correlation between observers was only fair to moderate (r ranging from 0.34-0.51). There were some surprisingly marked disagreements in 10-18% of assessments. The correlation between faecal loading and transit was weak for all observers (r ranging from 0.261-0.311). Symptom severity did not correlate with faecal loading. Conclusion: These results suggest that there is considerable inter-observer variation in the radiological assessment of faecal loading, irrespective of the training or method used by the observer, and that there is very poor correlation with colonic transit. The diagnosis of constipation, and the assessment of severity, is best performed clinically

  4. Comparison of three methods of calculating strain in the mouse ulna in exogenous loading studies.

    Science.gov (United States)

    Norman, Stephanie C; Wagner, David W; Beaupre, Gary S; Castillo, Alesha B

    2015-01-02

    Axial compression of mouse limbs is commonly used to induce bone formation in a controlled, non-invasive manner. Determination of peak strains caused by loading is central to interpreting results. Load-strain calibration is typically performed using uniaxial strain gauges attached to the diaphyseal, periosteal surface of a small number of sacrificed animals. Strain is measured as the limb is loaded to a range of physiological loads known to be anabolic to bone. The load-strain relationship determined by this subgroup is then extrapolated to a larger group of experimental mice. This method of strain calculation requires the challenging process of strain gauging very small bones which is subject to variability in placement of the strain gauge. We previously developed a method to estimate animal-specific periosteal strain during axial ulnar loading using an image-based computational approach that does not require strain gauges. The purpose of this study was to compare the relationship between load-induced bone formation rates and periosteal strain at ulnar midshaft using three different methods to estimate strain: (A) Nominal strain values based solely on load-strain calibration; (B) Strains calculated from load-strain calibration, but scaled for differences in mid-shaft cross-sectional geometry among animals; and (C) An alternative image-based computational method for calculating strains based on beam theory and animal-specific bone geometry. Our results show that the alternative method (C) provides comparable correlation between strain and bone formation rates in the mouse ulna relative to the strain gauge-dependent methods (A and B), while avoiding the need to use strain gauges. Published by Elsevier Ltd.

  5. Temporal mechanically-induced signaling events in bone and dorsal root ganglion neurons after in vivo bone loading.

    Directory of Open Access Journals (Sweden)

    Jason A Bleedorn

    Full Text Available Mechanical signals play an integral role in the regulation of bone mass and functional adaptation to bone loading. The osteocyte has long been considered the principle mechanosensory cell type in bone, although recent evidence suggests the sensory nervous system may play a role in mechanosensing. The specific signaling pathways responsible for functional adaptation of the skeleton through modeling and remodeling are not clearly defined. In vitro studies suggest involvement of intracellular signaling through mitogen-activated protein kinase (MAPK, phosphatidylinositol 3-kinase (PI3K/protein kinase B (Akt, and mammalian target of rapamycin (mTOR. However, anabolic signaling responses to bone loading using a whole animal in vivo model have not been studied in detail. Therefore, we examined mechanically-induced signaling events at five time points from 0 to 24 hours after loading using the rat in vivo ulna end-loading model. Western blot analysis of bone for MAPK's, PI3K/Akt, and mTOR signaling, and quantitative reverse transcription polymerase chain reaction (qRT-PCR to estimate gene expression of calcitonin gene-related protein alpha (CGRP-α, brain-derived neurotrophic factor (BDNF, nerve growth factor (NGF, c-jun, and c-fos in dorsal root ganglion (DRG of the brachial intumescence were performed. There was a significant increase in signaling through MAPK's including extracellular signal-related kinase (ERK and c-Jun N-terminal kinase (JNK in loaded limbs at 15 minutes after mechanical loading. Ulna loading did not significantly influence expression of the genes of interest in DRG neurons. Bone signaling and DRG gene expression from the loaded and contralateral limbs was correlated (SR>0.40, P<0.05. However, bone signaling did not correlate with expression of the genes of interest in DRG neurons. These results suggest that signaling through the MAPK pathway may be involved in load-induced bone formation in vivo. Further characterization of the

  6. Surface crack behavior in socket weld of nuclear piping under fatigue loading condition

    International Nuclear Information System (INIS)

    Choi, Y.H.; Kim, J.S.; Choi, S.Y.

    2005-01-01

    The ASME B and PV Code Sec. III allows the socket weld for the nuclear piping in spite of the weakness on the weld integrity. Recently, the integrity of the socket weld is regarded as a safety concern in nuclear power plants because many failures and leaks have been reported in the socket weld. OPDE (OECD Piping Failure Data Exchange) database lists 108 socket weld failures among 2,399 nuclear piping failure cases during 1970 to 2001. Eleven failures in the socket weld were also reported in Korean NPPs. Many failure cases showed that the root cause of the failure is the fatigue and the gap requirement for the socket weld given in ASME Code was not satisfied. The purpose of this paper is to evaluate the fatigue crack behavior of a surface crack in the socket weld under fatigue loading condition considering the gap effect. Three-dimensional finite element analysis was performed to estimate the fatigue crack behavior of the surface crack. Three types of loading conditions such as the deflection due to vibration, the pressure transient ranging from P=0 to 15.51 MPa, and the thermal transient ranging from T=25 C to 288 C were considered. The results are as follows; 1) The socket weld is susceptible to the vibration where the vibration levels exceed the requirement in the ASME operation and maintenance (OM) Code. 2) The effect of pressure or temperature transient load on the socket weld integrity is not significant. 3) No-gap condition gives very high possibility of the crack initiation at the socket weld under vibration loading condition. 4) For the specific systems having the vibration condition to exceed the requirement in the ASME Code OM and/or the transient loading condition from P=0 and T=25 C to P=15.51 MPa and T=288 C, radiographic examination to examine the gap during the construction stage is recommended. (orig.)

  7. Combustion and NOx emission characteristics of a retrofitted down-fired 660 MWe utility boiler at different loads

    Energy Technology Data Exchange (ETDEWEB)

    Li, Z.Q.; Liu, G.K.; Zhu, Q.Y.; Chen, Z.C.; Ren, F. [Harbin Institute of Technology, Harbin (China)

    2011-07-15

    Industrial experiments were performed for a retrofitted 660 MWe full-scale down-fired boiler. Measurements of ignition of the primary air/fuel mixture flow, the gas temperature distribution of the furnace and the gas components in the furnace were conducted at loads of 660, 550 and 330 MWe. With decreasing load, the gas temperature decreases and the ignition position of the primary coal/air flow becomes farther along the axis of the fuel-rich pipe in the burner region under the arches. The furnace temperature also decreases with decreasing load, as does the difference between the temperatures in the burning region and the lower position of the burnout region. With decreasing load, the exhaust gas temperature decreases from 129.8{sup o}C to 114.3{sup o}C, while NOx emissions decrease from 2448 to 1610 mg/m{sup 3}. All three loads result in low carbon content in fly ash and great boiler thermal efficiency higher than 92%. Compared with the case of 660 MWe before retrofit, the exhaust gas temperature decreased from 136 to 129.8{sup o}C, the carbon content in the fly ash decreased from 9.55% to 2.43% and the boiler efficiency increased from 84.54% to 93.66%.

  8. Effectively enhanced load transfer by interfacial reactions in multi-walled carbon nanotube reinforced Al matrix composites

    International Nuclear Information System (INIS)

    Zhou, Weiwei; Yamaguchi, Tatsuya; Kikuchi, Keiko; Nomura, Naoyuki; Kawasaki, Akira

    2017-01-01

    The thermal expansion response of multi-walled carbon nanotube (MWCNT) reinforced Al matrix composites was employed to discuss the improvement of the load transfer at the interface between the MWCNTs and the Al matrix. An aluminum carbide (Al_4C_3) nanostructure at the end of the MWCNTs, incorporated in the Al matrix, was produced by appropriate heat-treatment. The stress contrast around the Al_4C_3 observed in the high-resolution transmission electron microscopy (HRTEM) image revealed the evidence of a trace of friction, which would lead to the enhancement of the anchor effect from the Al matrix. This anchor effect of Al_4C_3 may hinder the local interfacial slippage and constrain the deformation of the Al matrix. As a result, the thermal expansion behavior became linear and reversible under cyclic thermal load. It is concluded that the formation of Al_4C_3 could effectively enhance the load transfer in MWCNT/Al composites. The yield strength of MWCNT/Al composites was substantially increased under the appropriate quantity of Al_4C_3 produced at the MWCNT-Al interface by precisely controlled heat-treatment.

  9. Spatial electric load forecasting

    CERN Document Server

    Willis, H Lee

    2002-01-01

    Spatial Electric Load Forecasting Consumer Demand for Power and ReliabilityCoincidence and Load BehaviorLoad Curve and End-Use ModelingWeather and Electric LoadWeather Design Criteria and Forecast NormalizationSpatial Load Growth BehaviorSpatial Forecast Accuracy and Error MeasuresTrending MethodsSimulation Method: Basic ConceptsA Detailed Look at the Simulation MethodBasics of Computerized SimulationAnalytical Building Blocks for Spatial SimulationAdvanced Elements of Computerized SimulationHybrid Trending-Simulation MethodsAdvanced

  10. Delamination behaviour in differently copper laminated REBCO coated conductor tapes under transverse loading

    Energy Technology Data Exchange (ETDEWEB)

    Gorospe, Alking [Department of Mechanical Design Engineering, Andong National University, 1375 Kyungdong-Ro, Andong 760-749 (Korea, Republic of); Department of Engineering, Aurora State College of Technology, Baler Aurora 3200 (Philippines); Nisay, Arman [Department of Mechanical Design Engineering, Andong National University, 1375 Kyungdong-Ro, Andong 760-749 (Korea, Republic of); Shin, Hyung-Seop, E-mail: hsshin@andong.ac.kr [Department of Mechanical Design Engineering, Andong National University, 1375 Kyungdong-Ro, Andong 760-749 (Korea, Republic of)

    2014-09-15

    Highlights: • I{sub c} degradation behavior under transverse tension loading in different CC tape structure. • Weibull distribution analysis applied on delamination mechanism of CC tape. • Delamination mechanism on CC tapes depending on copper lamination type. • SEM and WDS mapping analysis of delamination sites under transverse loading. - Abstract: Laminated HTS coated conductor (CC) tapes having a unique multi-layer structure made them vulnerable when exposed to transverse loading. Electromechanical transport properties of these CC tapes can be affected by excessive transverse stresses. Due to the coefficient of thermal expansion (CTE) mismatch and incompatibility among constituent materials used in coil applications, delamination among layers occurs and causes critical current, I{sub c} degradation in the CC tapes. In this study, the delamination behaviors in copper (Cu) solder-laminated CC tapes by soldering and surround Cu-stabilized ones by electroplating under transverse tension loading were investigated. Similarly to the surround Cu-stabilized CC tapes in our previous reports, the Cu solder-laminated CC tapes also showed an abrupt and gradual I{sub c} degradation behavior. However, the Cu solder-laminated CC tapes showed different delamination morphologies as compared to the surround Cu-stabilized CC tapes; the superconducting side and the substrate side of the Cu solder laminated CC tapes were totally separated by delamination. On the other hand, the brass laminate did not show any significant effect on the delamination strength when it is added upon the surround Cu-stabilized CC tapes.

  11. Hydrogen evolution reaction on electrodes with different PT/C loadings by electrochemical impedance spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Ortega-Chavez, L. [Inst. Tecnologico de Chihuahua 2, Chihuahua, Chih (Mexico); Ortega-Chavez, L.; Herrera-Peraza, E. [Centro de Investigacion en Materiales Avanzados, Chiuahua, Chih (Mexico); Verde, Y. [Inst. Tecnologico de Cancun, Cancun, Quintana Roo (Mexico)

    2008-04-15

    One of the most widely studied reactions in electrochemistry is the hydrogen evolution reaction (HER). HER is important for the development of water hydrolysis and fuel cell technologies. Because hydrogen-substrate interaction determines oxygen reduction efficiency, an understanding of the chemical and electronic state of hydrogen adsorbed on the electrocatalyst surface is required. Electrochemical impedance spectroscopy (EIS) is a proven highly efficient technique for interface characterization and kinetic parameter determination for different reactions carried out on interfaces. This article presented a study that utilized EIS for characterizing electrodes under HER by implementing a rotating disc electrode with different carbon supported platinum nanoparticles loadings and different potentials in acidic solutions. The results collected by EIS were analyzed in terms of equivalent circuits to calculate different parameters which were compared by statistical analysis. The study also considered the Volmer, Heyrovsky and Tafel steps in the HER reaction as well as a single electro-absorbed intermediate species. The article discussed the experimental set-up with reference to measurements, simulation and fitting. Parameters analysis using ANOVA were reviewed. It was concluded that an increase in impedance occurs when platinum loading decreases in both high and low frequencies. 22 refs., 1 tab., 5 figs.

  12. Full-scale locomotive dynamic crash testing and correlations : C-39 type locomotive colliding with a loaded hopper car (test 7).

    Science.gov (United States)

    2011-09-01

    This report presents the results of a locomotive and three loaded hopper car consist traveling at 29 miles per hour colliding with a stationary consist of 35 loaded hopper cars. The details of test instrumentation, LS-DYNA finite element simulation, ...

  13. Field Demonstration of Propane Biosparging for In Situ Remediation of NNitrosodimethylamine (NDMA) in Groundwater. Cost and Performance Report

    Science.gov (United States)

    2015-12-30

    fluidization pump, an influent distribution system and effluent/ biomass collection system, two biomass separators, 7,100 lbs of carbon media (coconut shell ...ratio of oxygen (O2) to propane (C3H8) for complete oxidation of propane to carbon dioxide (CO2; not accounting for microbial biomass incorporation

  14. Active Match Load Circuit Intended for Testing Piezoelectric Transformers

    DEFF Research Database (Denmark)

    Andersen, Thomas; Rødgaard, Martin Schøler; Andersen, Michael A. E.

    2012-01-01

    An adjustable high voltage active load circuit for voltage amplitudes above 100 volts, especially intended for resistive matching the output impedance of a piezoelectric transformer (PT) is proposed in this paper. PTs have been around for over 50 years, were C. A. Rosen is common known for his...

  15. Shot loading platform analysis

    International Nuclear Information System (INIS)

    Norman, B.F.

    1994-01-01

    This document provides the wind/seismic analysis and evaluation for the shot loading platform. Hand calculations were used for the analysis. AISC and UBC load factors were used in this evaluation. The results show that the actual loads are under the allowable loads and all requirements are met

  16. WATER SORPTION PROPERTIES AND ANTIMICROBIAL ACTION OF ZINC OXIDE NANO PARTICLES LOADED SAGO STARCH FILM

    Directory of Open Access Journals (Sweden)

    Sunil Bajpai

    2013-02-01

    Full Text Available In this work, sago starch based films have been loaded with ZnO nanoparticles prepared insitu via using an unique equilibration-cum-hydrothermal approach. The films have been characterized by XRD, DSC,SPR ,FTIR and SEM analysis. The moisture absorption behavior of plain and ZnO nanoparticles loaded films have been studied at 23, 31 and 37o C.The equilibrium moisture uptake data was found to fit well on GAB isotherm model and the monolayer sorption capacity Mo for the plain and ZnO nanoparticles loaded films was 0.089, 0.039 ,0.021 g/g and 0.042, 0.012, 0.007 g/g at 23,31 and 37 oC respectively. Moreover, the water vapor transmission rates (WVTR for plain and ZnO nanoparticles loaded films at 23,31,37 oC were 11.19x10-4, 48.9x10-4, 62.1x10-4 and 3.73 x10-4, 6.21x10-4, 24.8x10-4 respectively. These films have shown excellent antibacterial action against model bacteria E.coli when investigated qualitatively by zone inhibition method. Films exhibit great potential to be used as packaging films to protect food stuff against microbial contaminents.

  17. Note: Loading method of molecular fluorine using x-ray induced chemistry

    International Nuclear Information System (INIS)

    Pravica, Michael; Sneed, Daniel; White, Melanie; Wang, Yonggang

    2014-01-01

    We have successfully loaded molecular fluorine into a diamond anvil cell at high pressure using the synchrotron x-ray induced decomposition of perfluorohexane (C 6 F 14 ). “White” x-ray radiation from the Advanced Photon Source was used to initiate the chemical decomposition of C 6 F 14 , which resulted in the in situ production of F 2 as verified via Raman spectroscopy. Due to the toxic nature of fluorine, this method will offer significant advantages in the ability to easily load a relatively nontoxic and inert substance into a chamber (such as a diamond anvil cell) that, when sealed with other reactants and irradiate with hard x-rays (>7 keV), releases highly reactive and toxic fluorine into the sample/reaction chamber to enable novel chemical synthesis under isolated and/or extreme conditions

  18. Optimisation of load control

    International Nuclear Information System (INIS)

    Koponen, P.

    1998-01-01

    Electricity cannot be stored in large quantities. That is why the electricity supply and consumption are always almost equal in large power supply systems. If this balance were disturbed beyond stability, the system or a part of it would collapse until a new stable equilibrium is reached. The balance between supply and consumption is mainly maintained by controlling the power production, but also the electricity consumption or, in other words, the load is controlled. Controlling the load of the power supply system is important, if easily controllable power production capacity is limited. Temporary shortage of capacity causes high peaks in the energy price in the electricity market. Load control either reduces the electricity consumption during peak consumption and peak price or moves electricity consumption to some other time. The project Optimisation of Load Control is a part of the EDISON research program for distribution automation. The following areas were studied: Optimization of space heating and ventilation, when electricity price is time variable, load control model in power purchase optimization, optimization of direct load control sequences, interaction between load control optimization and power purchase optimization, literature on load control, optimization methods and field tests and response models of direct load control and the effects of the electricity market deregulation on load control. An overview of the main results is given in this chapter

  19. Optimisation of load control

    Energy Technology Data Exchange (ETDEWEB)

    Koponen, P [VTT Energy, Espoo (Finland)

    1998-08-01

    Electricity cannot be stored in large quantities. That is why the electricity supply and consumption are always almost equal in large power supply systems. If this balance were disturbed beyond stability, the system or a part of it would collapse until a new stable equilibrium is reached. The balance between supply and consumption is mainly maintained by controlling the power production, but also the electricity consumption or, in other words, the load is controlled. Controlling the load of the power supply system is important, if easily controllable power production capacity is limited. Temporary shortage of capacity causes high peaks in the energy price in the electricity market. Load control either reduces the electricity consumption during peak consumption and peak price or moves electricity consumption to some other time. The project Optimisation of Load Control is a part of the EDISON research program for distribution automation. The following areas were studied: Optimization of space heating and ventilation, when electricity price is time variable, load control model in power purchase optimization, optimization of direct load control sequences, interaction between load control optimization and power purchase optimization, literature on load control, optimization methods and field tests and response models of direct load control and the effects of the electricity market deregulation on load control. An overview of the main results is given in this chapter

  20. Optimizing ROOT’s Performance Using C++ Modules

    Science.gov (United States)

    Vassilev, Vassil

    2017-10-01

    ROOT comes with a C++ compliant interpreter cling. Cling needs to understand the content of the libraries in order to interact with them. Exposing the full shared library descriptors to the interpreter at runtime translates into increased memory footprint. ROOT’s exploratory programming concepts allow implicit and explicit runtime shared library loading. It requires the interpreter to load the library descriptor. Re-parsing of descriptors’ content has a noticeable effect on the runtime performance. Present state-of-art lazy parsing technique brings the runtime performance to reasonable levels but proves to be fragile and can introduce correctness issues. An elegant solution is to load information from the descriptor lazily and in a non-recursive way. The LLVM community advances its C++ Modules technology providing an io-efficient, on-disk representation capable to reduce build times and peak memory usage. The feature is standardized as a C++ technical specification. C++ Modules are a flexible concept, which can be employed to match CMS and other experiments’ requirement for ROOT: to optimize both runtime memory usage and performance. Cling technically “inherits” the feature, however tweaking it to ROOT scale and beyond is a complex endeavor. The paper discusses the status of the C++ Modules in the context of ROOT, supported by few preliminary performance results. It shows a step-by-step migration plan and describes potential challenges which could appear.

  1. Monotonic, Creep-Rupture, and Fatigue Behavior of Carbon Fiber Reinforced Silicon Carbide (C/SiC) at an Elevated Temperature

    National Research Council Canada - National Science Library

    Engesser, John

    2004-01-01

    .... Cyclic loading of C/SiC was investigated at frequencies of 375 Hz, 10 Hz, 1 Hz, and 0.1 Hz. Creep-Rupture tests and tests that were combinations of creep-rupture and fatigue were also accomplished...

  2. Ambient temperature and neck EMG with +Gz loading on a trampoline.

    Science.gov (United States)

    Sovelius, Roope; Oksa, Juha; Rintala, Harri; Huhtala, Heini; Siitonen, Simo

    2007-06-01

    Fighter pilots who are frequently exposed to severe cold ambient temperatures experience neck pain disabilities and occupational disorders more often than those who are not so exposed. We hypothesized that a cold-induced increase in muscle strain might lead to in-flight neck injuries. The aims of this study were to measure the level of cooling before takeoff and to determine muscle strain under Gz loading (0 to +4 Gz) at different temperatures. Test subjects' (n = 14) skin temperature (T(skin)) over the trapezoids was measured before the walk to the aircraft and again in the cockpit (air temperature -14 degrees C). The subjects then performed trampoline exercises in two different ambient temperatures (-2 degrees C and +21 degrees C) after a 30-min period at the respective temperatures. EMG activity of the sternocleidomastoid (SCM), cervical erector spinae (CES), trapezoid (TRA), thoracic erector spinae (TES) muscles, and Tskin of the SCM and TRA were measured. Tskin over the trapezoids decreased from 30.1 +/- 1.7 degrees C to 27.8 +/- 2.6 degrees C (p < 0.001) before takeoff. The change of muscle strain in cold was +11.0% in SCM, +14.9% in CES, +3.7% in TRA, and -1.7% in TES. Change was statistically significant in the cervical, uncovered area (SCM, CES). The linear regression model indicated a 2.6% increase in muscle strain per every decreased degree centigrade in skin temperature over the SCM. Superficial cooling over the neck muscles was significant prior to takeoff. Muscle loading in the cold caused higher EMG activity. A major increase in muscle strain was seen in the cervical muscles. These findings suggest a cold-induced increase in muscle strain during in-flight Gz loading.

  3. Thermoregulatory responses to acute heat loads in rats following spontaneous running.

    Science.gov (United States)

    Sugimoto, N; Shido, O; Sakurada, S; Nagasaka, T

    1999-02-01

    Earlier studies showed that spontaneous exercise training in rodents shifted their core temperature and thermoeffector thresholds to high levels. The present study investigated heat loss and heat production responses to acute heat loads of exercise-trained rats. The exercise-trained rats were allowed to run in a running wheel freely for 6 months, while the sedentary controls were denied access to the wheel during the same period. Then, they were loosely restrained and put in a direct calorimeter. After thermal equilibrium had been attained, they were warmed for 30 min with an intraperitoneal electric heater (internal heating). At least 2 h later, the rats were externally warmed for 90 min by raising the ambient temperature from 24 to 38C (external warming). Hypothalamic temperature (Thy), evaporative and nonevaporative heat loss (R+C+K) and heat production were measured. Internal and external heating significantly increased Thy. During internal heating, the magnitude of the increase in Thy was significantly smaller and the amount of increase in (R+C+K) was significantly greater in the exercise-trained rats than in the controls. The slope showing the relationship between Thy and (R+C+K) in the trained rats was significantly steeper than that in the controls. During external warming, the magnitude of increase in Thy of the exercise-trained rats was significantly greater than that of the controls. The slope showing the relationship between Thy and (R+C+K) in the trained rats was not different from that in the controls. Changes in evaporative heat loss and heat production during the two types of heat load did not differ between the two groups. The results suggest that, in rats, exercise training with voluntary running improves heat tolerance through enhancing nonevaporative heat loss response. However, this may be the case only when the rats are subjected to a direct internal heat load.

  4. Proposed Optimal Fluoroscopic Targets for Cooled Radiofrequency Neurotomy of the Sacral Lateral Branches to Improve Clinical Outcomes: An Anatomical Study.

    Science.gov (United States)

    Stout, Alison; Dreyfuss, Paul; Swain, Nathan; Roberts, Shannon; Loh, Eldon; Agur, Anne

    2017-11-23

    Current sacroiliac joint (SIJ) cooled radiofrequency (RF) is based on fluoroscopic anatomy of lateral branches (LBs) in three specimens. Recent studies confirm significant variation in LB positions. To determine if common fluoroscopic needle placements for cooled SIJ RF are adequate to lesion all S1-3 LBs. If not, would different targets improve lesion accuracy? The LBs of 20 cadavers were dissected bilaterally (40 SIJs), and 26 G radiopaque wires were sutured to the LBs. With a 10-mm radius ruler centered at each foramen, standard targets were assessed, as judged by a clockface on the right, for S1 and S2 at 2:30, 4:00, and 5:30 positions and at S3 at 2:30 and 4:00. Mirror image targets were assessed on the left. Assuming an 8-mm lesion diameter, the percentage of LBs that would not be ablated for each level was determined. Imaging through the superior end plate of S1 was compared against segment specific (SS) imaging. Nine point four percent of LBs would not be ablated at S1 vs 0.99% at S2 vs 35% at S3, and 60% of the 40 SIJs would be completely denervated using current targets. SS imaging did not improve results. Alternate target locations could improve the miss rate to 2.8% at S1 and 0% at S3 and would ablate all LBs in 95% of SIJs. Using a conservative 8-mm lesion measurement, contemporary cooled RF needle targets are inadequate to lesion all target LBs. Modifications to current targets are recommended to increase the effectiveness of the procedure. © 2017 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  5. A More Realistic Lateral Load Pattern for Design of Reinforced Concrete Buildings with Moment Frames and Shear Walls

    International Nuclear Information System (INIS)

    Hosseini, Mahmood; Khosahmadi, Arash

    2008-01-01

    In this research it has been tried to find a more realistic distribution pattern for the seismic load in reinforced concrete (R/C) buildings, having moment frames with shear walls as their lateral resisting system, by using Nonlinear Time History Analyses (NLTHA). Having shear wall as lateral load bearing system decreases the effect of infill walls in the seismic behavior of the building, and therefore the case of buildings with shear walls has been considered for this study as the first stage of the studies on lateral load patterns for R/C buildings. For this purpose, by assuming three different numbers of bays in each direction and also three different numbers of stories for the buildings, several R/C buildings, have been studied. At first, the buildings have been designed by the Iranian National Code for R/C Buildings. Then they have been analyzed by a NLTHA software using the accelerograms of some well-known earthquakes. The used accelerograms have been also scaled to various levels of peak ground acceleration (PGA) such as 0.35 g, 0.50 g, and 0.70 g, to find out the effect of PGA in the seismic response. Numerical results have shown that firstly the values of natural period of the building and their shear force values, calculated by the code, are not appropriate in all cases. Secondly, it has been found out that the real lateral load pattern is quite different with the one suggested by the seismic code. Based on the NLTHA results a new lateral load pattern has been suggested for this kind of buildings, in the form of some story-dependent modification factors applied to the existing code formula. The effects of building's natural period, as well as its number of stories, are taken into account explicitly in the proposed new load pattern. The proposed load pattern has been employed to redesign the buildings and again by NLTHA the real lateral load distribution in each case has been obtained which has shown very good agreement with the proposed pattern

  6. Task-irrelevant memory load induces inattentional blindness without temporo-parietal suppression.

    Science.gov (United States)

    Matsuyoshi, Daisuke; Ikeda, Takashi; Sawamoto, Nobukatsu; Kakigi, Ryusuke; Fukuyama, Hidenao; Osaka, Naoyuki

    2010-08-01

    We often fail to consciously detect an unexpected object when we are engaged in an attention-demanding task (inattentional blindness). The inattentional blindness which is induced by visual short-term memory (VSTM) load has been proposed to result from a suppression of temporo-parietal junction (TPJ) activity that involves stimulus-driven attention. However, the fact that, inversely proportional to TPJ activity, intraparietal sulcus (IPS) activity correlates with VSTM load renders questionable the account of inattentional blindness based only on TPJ activity. Here, we investigated whether the TPJ is solely responsible for inattentional blindness by decoupling IPS and TPJ responses to VSTM load and then using the same manipulation to test the behavioral inattentional blindness performance. Experiment 1 showed that TPJ activity was not suppressed by task-irrelevant load while the IPS responded to both task-relevant and task-irrelevant load. Although the TPJ account of inattentional blindness predicts that the degree of inattentional blindness should track TPJ activity, we found in Experiment 2 that inattentional blindness was induced not only by task-relevant load but also by task-irrelevant load, showing inconsistency between the extent of inattentional blindness and TPJ response. These findings suggest that inattentional blindness can be induced without suppression of TPJ activity and seem to offer the possibility that the IPS contributes to conscious perception. Copyright (c) 2010 Elsevier Ltd. All rights reserved.

  7. Creep of MDF panels under constant load and cyclic environmental conditions. Influence of surface coating

    OpenAIRE

    Fernández-Golfín Seco, J. I.; Díez Barra, M. Rafael

    1997-01-01

    Four different strategies of surface coating (based on 80 g m2 melamin impregnated papers) were used on 19 mm thick commercial MDF panels to assess its reological behaviour under cyclic humidity conditions (20ºC 30 % rh-20ºC 90 % rh). Three different levels of stress (20 %, 30 % and 40 %), based on the ultimate load in bending, were used. Tests were conducted by means of the three points load system. For the same stress level, the relative creep of MDF panels was higher than that in par...

  8. Use Of Ultra Violet Light (UV-C) To Reduce Possible Microbial Potential In Cold Storage Rooms Loaded With Sweet Potatoes For Exportation

    International Nuclear Information System (INIS)

    Yassin, Sh.M.; El-Neshawy, S.M.; Aly, A.Z.; Abdel Kader, D.A.

    2012-01-01

    Irradiation with Ultraviolet-c (UV-C) light (254 nm) was applied on sweet potatoes (cv. Abees) as well as the major recovered organisms that are accounted as contaminants in either the internal atmosphere or on sweet potato tuber roots loaded in cold storage room set at 17 degree C and 65-70% RH for 3 months. The captured types of microorganisms from either the internal atmosphere of cold storage room or surfaces of sweet potato tuber roots were fungi, yeast and bacteria with the greatest percentage of fungi that recorded 90% and 70%, respectively. The major individuals of recovered fungi were Penicillium spp., Alternaria alternata, Rhizopus stolonifer, Aspergillus spp., Botrytis cinerea, and Fusarium sp. in descending order of their existence percentages. Upon exposure, the internal atmosphere to UV-C light for one, two and three hours inside cold storage room, a significant reduction of the total number of different types of organisms was obtained with the greatest effect for the three hour-exposure time. Exposure of sweet potatoes to UV-C light at three exposure times (1, 2 and 3 hr) and stored in cold rooms for one month caused a reduction of rot percentages upon natural infection conditions with a full reduction (0 %) when irradiated for 3 hr at the same conditions. Rot percentages were decreased as the exposure time increased. Fruit characteristics in terms of tuber root firmness, shrinking and blemishing of irradiated tuber roots were remarkably maintained than which of the non irradiated ones. UV-C light caused a significant increase in phenol contents in tuber root tissue, while a reverse effect in sugar content was detected; such effects were correlated increasingly or decreasingly with the increase of exposure time. The activity of peroxidase, polyphenoloxidase or poly phenylalanine ammonia lyase (PAL) enzymes in irradiated tuber root tissues were significantly enhanced as the exposure time increased

  9. Functional electrical stimulation of intrinsic laryngeal muscles under varying loads in exercising horses.

    Directory of Open Access Journals (Sweden)

    Jon Cheetham

    Full Text Available Bilateral vocal fold paralysis (BVCP is a life threatening condition and appears to be a good candidate for therapy using functional electrical stimulation (FES. Developing a working FES system has been technically difficult due to the inaccessible location and small size of the sole arytenoid abductor, the posterior cricoarytenoid (PCA muscle. A naturally-occurring disease in horses shares many functional and etiological features with BVCP. In this study, the feasibility of FES for equine vocal fold paralysis was explored by testing arytenoid abduction evoked by electrical stimulation of the PCA muscle. Rheobase and chronaxie were determined for innervated PCA muscle. We then tested the hypothesis that direct muscle stimulation can maintain airway patency during strenuous exercise in horses with induced transient conduction block of the laryngeal motor nerve. Six adult horses were instrumented with a single bipolar intra-muscular electrode in the left PCA muscle. Rheobase and chronaxie were within the normal range for innervated muscle at 0.55±0.38 v and 0.38±0.19 ms respectively. Intramuscular stimulation of the PCA muscle significantly improved arytenoid abduction at all levels of exercise intensity and there was no significant difference between the level of abduction achieved with stimulation and control values under moderate loads. The equine larynx may provide a useful model for the study of bilateral fold paralysis.

  10. Finite element-based limit load of piping branch junctions under combined loadings

    International Nuclear Information System (INIS)

    Xuan Fuzhen; Li Peining

    2004-01-01

    The limit load is an important input parameter in engineering defect-assessment procedures and strength design. In the present work, a total of 100 different piping branch junction models for the limit load calculation were performed under combined internal pressure and moments in use of non-linear finite element (FE) method. Three different existing accumulation rules for limit load, i.e., linear equation, parabolic equation and quadratic equation were discussed on the basis of FE results. A novel limit load solution was developed based on detailed three-dimensional FE limit analyses which accommodated the geometrical parameter influence, together with analytical solutions based on equilibrium stress fields. Finally, six experimental results were provided to justify the presented equation. According to the FE limit analysis, limit load interaction of the piping tees under combined pressure and moments has a relationship with the geometrical parameters, especially with the diameter ratio d/D. The predicted limit loads from the presented formula are very close to the experimental data. The resulting limit load solution is given in a closed form, and thus can be easily used in practice

  11. Short term load forecasting of anomalous load using hybrid soft computing methods

    Science.gov (United States)

    Rasyid, S. A.; Abdullah, A. G.; Mulyadi, Y.

    2016-04-01

    Load forecast accuracy will have an impact on the generation cost is more economical. The use of electrical energy by consumers on holiday, show the tendency of the load patterns are not identical, it is different from the pattern of the load on a normal day. It is then defined as a anomalous load. In this paper, the method of hybrid ANN-Particle Swarm proposed to improve the accuracy of anomalous load forecasting that often occur on holidays. The proposed methodology has been used to forecast the half-hourly electricity demand for power systems in the Indonesia National Electricity Market in West Java region. Experiments were conducted by testing various of learning rate and learning data input. Performance of this methodology will be validated with real data from the national of electricity company. The result of observations show that the proposed formula is very effective to short-term load forecasting in the case of anomalous load. Hybrid ANN-Swarm Particle relatively simple and easy as a analysis tool by engineers.

  12. Determination of thermal reactivity coefficients for the first fuel loading of MO34

    International Nuclear Information System (INIS)

    Lueley, J.; Vrban, B.; Farkas, G.; Hascik, J.; Hinca, R.; Petriska, M.; Slugen, V.

    2012-01-01

    The article introduces determination of thermal reactivity coefficients, especially summarized (isothermal) and moderator (density) reactivity coefficients between 200 grad C and 260 grad C with 2 grad C step, - in compliance with the assignment - for the first fuel loading into the RC of NP Mochovce units using 2 nd generation fuel during the start-up using calculation code MCNP5 1.60. (authors)

  13. Bounding estimate of DWPF mercury emissions

    International Nuclear Information System (INIS)

    Jacobs, R.A.

    1992-01-01

    Purges required for H2 flammability control and verification of elevated Formic Acid Vent Condenser (FAVC) exit temperatures due to NO x reactions have lead to significant changes in Chemical Process Cell (CPC) operating conditions. Accordingly, mercury emissions estimates have been updated based upon the new operating requirements, IDMS (Integrated DWPF Melter System) experience, and development of an NO x /FAVC model which predicts FAVC exit temperatures. Using very conservative assumptions and maximum purge rates, the maximum calculated Hg emissions is approximately 130 lbs/yr. A range of 100 to 120 lbs/yr is conservatively predicted for other operating conditions. Defense Waste Processing Facility (DWPF) permitted Hg emissions are 175 lbs/yr (0.02 lbs/hr annual average)

  14. Determining the optimal load for jump squats: a review of methods and calculations.

    Science.gov (United States)

    Dugan, Eric L; Doyle, Tim L A; Humphries, Brendan; Hasson, Christopher J; Newton, Robert U

    2004-08-01

    There has been an increasing volume of research focused on the load that elicits maximum power output during jump squats. Because of a lack of standardization for data collection and analysis protocols, results of much of this research are contradictory. The purpose of this paper is to examine why differing methods of data collection and analysis can lead to conflicting results for maximum power and associated optimal load. Six topics relevant to measurement and reporting of maximum power and optimal load are addressed: (a) data collection equipment, (b) inclusion or exclusion of body weight force in calculations of power, (c) free weight versus Smith machine jump squats, (d) reporting of average versus peak power, (e) reporting of load intensity, and (f) instructions given to athletes/ participants. Based on this information, a standardized protocol for data collection and reporting of jump squat power and optimal load is presented.

  15. Thermal loading study for FY 1996. Volume 2

    International Nuclear Information System (INIS)

    1996-01-01

    The primary objective of this study was to provide recommendations for Mined Geologic Disposal System requirements affected by thermal loading that will provide sufficient definition to facilitate development of design concepts and support life cycle cost determinations. The study reevaluated and/or redefined selected thermal goals used for design and are currently contained in the requirements documents or the Controlled Design Assumption Document. The study provided recommendations as to what, if any, actions (such as edge loading and limiting of the heat variability between waste packages) are needed and must be accommodated in the design. Additionally, the study provided recommendations as to what alternative thermal loads should be maintained for continued flexibility. This report contains seven appendices: Technical basis for evaluation of thermal goals below the potential nuclear was repository at Yucca Mountain; Thermal-mechanical evaluation of the 200 C drift-wall temperature goal; Evaluation of ground stability and support; Coupled ventilation and hydrothermal evaluations; Heat flow and temperature calculations for continuously ventilated emplacement drifts; Thermal management using aging and/or waste package selection; and Waste stream evaluations

  16. Improving automated load flexibility of nuclear power plants with ALFC

    Energy Technology Data Exchange (ETDEWEB)

    Kuhn, Andreas [AREVA GmbH, Karlstein (Germany). Plant Control/Training; Klaus, Peter [E.ON NPP Isar 2, Essenbach (Germany). Plant Operation/Production Engineering

    2016-07-01

    In several German and Swiss Nuclear Power Plants with Pressurized Water Reactor (PWR) the control of the reactor power was and will be improved in order to be able to support the energy transition with increasing volatile renewable energy in the grid by flexible load operation according to the need of the load dispatcher (power system stability). Especially regarding the mentioned German NPPs with a nominal electric power of approx. 1,500 MW, the general objectives are the main automated grid relevant operation modes. The new possibilities of digital I and C (as TELEPERM {sup registered} XS) enable the automation of the operating modes provided that manual support is no longer necessary. These possibilities were and will be implemented by AREVA within the ALFC-projects. Manifold adaption algorithms to the reactor physical variations during the nuclear load cycle enable a precise control of the axial power density distribution and of the reactivity management in the reactor core. Finally this is the basis for a highly automated load flexibility with the parallel respect and surveillance of the operational limits of a PWR.

  17. Improving automated load flexibility of nuclear power plants with ALFC

    Energy Technology Data Exchange (ETDEWEB)

    Kuhn, Andreas [AREVA GmbH, Karlstein (Germany). Section Manager Training; Klaus, Peter [Preussenelektra NPP, Essenbach (Germany). Production Engineering

    2017-03-15

    In several German and Swiss Nuclear Power Plants with Pressurized Water Reactor (PWR) the control of the reactor power was and will be improved in order to be able to support the energy transition with increasing volatile renewable energy in the grid by flexible load operation according to the need of the load dispatcher (power system stability). Especially regarding the mentioned German NPPs with a nominal electric power of approx. 1500 MW, the general objectives are several automated grid relevant operation modes. The new possibilities of digital I and C (as TELEPERM {sup registered} XS) enable the automation of this operating modes provided that manual support is no longer necessary. These possibilities were and will be implemented by AREVA within the ALFC-projects. Manifold adaption algorithms to the reactor physical variations during the nuclear load cycle enable a precise control of the axial power density distribution and of the reactivity manage - ment in the reactor core. Finally this is the basis for a highly automated load flexibility with the parallel respect and surveillance of the operational limits of a PWR.

  18. Polymer price hikes meet mixed results

    International Nuclear Information System (INIS)

    Coeyman, M.

    1993-01-01

    Quantum's announcement that it will temporarily shut down 150 million lbs/year of high-density polyethylene (HDPE) capacity at its Clinton, IA plant did little to lift spirits among fellow producers. There's still a lot of capacity out there - and a lot more due to come on, say one. Many agree with Charles Neivert, president of New Vernon Associates (Morristown, NJ), who sums up the cutback in three words: Not nearly enough. Despite the loss of 250 million-275 million lbs/year of HDPE capacity last year when OxyChem shut down its Orange, TX plant, and an additional 400 million lbs/year during the month of December when Solvay took equipment down for maintenance at Deer Park, TX, the market is still awash in capacity. In addition, Phillips is planning to bring 600 million lbs/year online late this year, while Formosa is scheduled to add 500 million lbs/year and Himont 200 million lbs/year, both in 1994. HDPE producers have been trying for a price increase since August but so far have not succeeded. The polypropylene market looks much the same. Low-density PE, however is quite another story. Although the 2-cts/lb price initiative on Jan. 1 failed, a Feb. 1 increase seems likely to stick

  19. Effect of regulated deficit irrigation and crop load on the antioxidant compounds of peaches.

    Science.gov (United States)

    Buendía, Begoña; Allende, Ana; Nicolás, Emilio; Alarcón, Juan J; Gil, Maria I

    2008-05-28

    The use of regulated deficit irrigation (RDI) strategies is becoming a common practice in areas with low water availability. Little information is available about the effects of RDI on the antioxidant content of fruits. In this study, the influence of RDI on the content of vitamin C, phenolic compounds and carotenoids was investigated. Two irrigation strategies, fully irrigated (FI) and RDI, were compared at two levels of thinning, commercial and half of the commercial crop load. RDI strategies affected the content of vitamin C, phenolics and carotenoids of Flordastar peaches. RDI caused fruit peel stress lowering the content of vitamin C and carotenoids, while increasing the phenolic content, mainly anthocyanins and procyanidins. Fruit weight was the only quality index influenced by the crop load as it increased in FI fruits at low crop load. In general, fruits from commercial crop load had slightly higher content of antioxidants to fruits from low crop load, although these influences were only observed in the peel. Additionally, the influence of irrigation controlled by two sensors related to plant water level, maximum daily trunk shrinkage (MDS) and sap flow (SF) on the antioxidant constituents of peaches was evaluated. The response of the fruits to SF sensor was similar to that observed for RDI strategy. According to the tested water sensors, SF did not act as a good plant-based water indicator for use in irrigation scheduling, as it caused an increase in the content of phenolics, similar to that observed for fruits subjected to RDI. Therefore, selection of RDI strategies and plant water indicators should be taken into account as they affect the content of antioxidants of peaches.

  20. Load-redistribution strategy based on time-varying load against cascading failure of complex network

    International Nuclear Information System (INIS)

    Liu Jun; Shi Xin; Wang Kai; Shi Wei-Ren; Xiong Qing-Yu

    2015-01-01

    Cascading failure can cause great damage to complex networks, so it is of great significance to improve the network robustness against cascading failure. Many previous existing works on load-redistribution strategies require global information, which is not suitable for large scale networks, and some strategies based on local information assume that the load of a node is always its initial load before the network is attacked, and the load of the failure node is redistributed to its neighbors according to their initial load or initial residual capacity. This paper proposes a new load-redistribution strategy based on local information considering an ever-changing load. It redistributes the loads of the failure node to its nearest neighbors according to their current residual capacity, which makes full use of the residual capacity of the network. Experiments are conducted on two typical networks and two real networks, and the experimental results show that the new load-redistribution strategy can reduce the size of cascading failure efficiently. (paper)

  1. Polyinosinic:polycytidylic acid loading onto different generations of PAMAM dendrimer-coated magnetic nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Khodadust, Rouhollah, E-mail: raoul.1357@gmail.com [Middle East Technical University, Department of Biotechnology (Turkey); Mutlu, Pelin [Middle East Technical University, Central Laboratory, Molecular Biology and Biotechnology R and D Center (Turkey); Yalc Latin-Small-Letter-Dotless-I n, Serap [Ahi Evran University, Department of Food Engineering (Turkey); Unsoy, Gozde; Gunduz, Ufuk, E-mail: ufukg@metu.edu.tr [Middle East Technical University, Department of Biotechnology (Turkey)

    2013-08-15

    Poly (I:C), which is a synthetic double-stranded RNA, have significant toxicity on tumor cells. The immobilization of Poly (I:C) onto nanoparticles is important for the fabrication of targeted delivery systems. In this study, different generations of newly synthesized PAMAM dendron-coated magnetic nanoparticles (DcMNP) which can be targeted to the tumor site under magnetic field were efficiently loaded for the first time with Poly (I:C). Different generations of DcMNPs (G{sub 2}, G{sub 3}, G{sub 4}, G{sub 5}, G{sub 6}, and G{sub 7}) were synthesized. Poly (I:C) activation was achieved in the presence of EDC and 1-methylimidazole. Loading of Poly (I:C) onto DcMNPs was followed by agarose gel electrophoresis. Acidic reaction conditions were found as superior to basic and neutral for binding of Poly (I:C). In addition, having more functional groups at the surface, higher generations (G{sub 7}, G{sub 6}, and G{sub 5}) of PAMAM DcMNPs were found more suitable as a delivery system for Poly (I:C). Further in vitro and in vivo analyses of Poly (I:C)/PAMAM magnetic nanoparticles may provide new opportunities for the selective targeting and killing of tumor cells.

  2. Laterally loaded masonry

    DEFF Research Database (Denmark)

    Raun Gottfredsen, F.

    In this thesis results from experiments on mortar joints and masonry as well as methods of calculation of strength and deformation of laterally loaded masonry are presented. The strength and deformation capacity of mortar joints have been determined from experiments involving a constant compressive...... stress and increasing shear. The results show a transition to pure friction as the cohesion is gradually destroyed. An interface model of a mortar joint that can take into account this aspect has been developed. Laterally loaded masonry panels have also been tested and it is found to be characteristic...... that laterally loaded masonry exhibits a non-linear load-displacement behaviour with some ductility....

  3. Critical Axial Load

    Directory of Open Access Journals (Sweden)

    Walt Wells

    2008-01-01

    Full Text Available Our objective in this paper is to solve a second order differential equation for a long, simply supported column member subjected to a lateral axial load using Heun's numerical method. We will use the solution to find the critical load at which the column member will fail due to buckling. We will calculate this load using Euler's derived analytical approach for an exact solution, as well as Euler's Numerical Method. We will then compare the three calculated values to see how much they deviate from one another. During the critical load calculation, it will be necessary to calculate the moment of inertia for the column member.

  4. Tibial loading increases osteogenic gene expression and cortical bone volume in mature and middle-aged mice.

    Directory of Open Access Journals (Sweden)

    Matthew J Silva

    Full Text Available There are conflicting data on whether age reduces the response of the skeleton to mechanical stimuli. We examined this question in female BALB/c mice of different ages, ranging from young to middle-aged (2, 4, 7, 12 months. We first assessed markers of bone turnover in control (non-loaded mice. Serum osteocalcin and CTX declined significantly from 2 to 4 months (p<0.001. There were similar age-related declines in tibial mRNA expression of osteoblast- and osteoclast-related genes, most notably in late osteoblast/matrix genes. For example, Col1a1 expression declined 90% from 2 to 7 months (p<0.001. We then assessed tibial responses to mechanical loading using age-specific forces to produce similar peak strains (-1300 µε endocortical; -2350 µε periosteal. Axial tibial compression was applied to the right leg for 60 cycles/day on alternate days for 1 or 6 weeks. qPCR after 1 week revealed no effect of loading in young (2-month mice, but significant increases in osteoblast/matrix genes in older mice. For example, in 12-month old mice Col1a1 was increased 6-fold in loaded tibias vs. controls (p = 0.001. In vivo microCT after 6 weeks revealed that loaded tibias in each age group had greater cortical bone volume (BV than contralateral control tibias (p<0.05, due to relative periosteal expansion. The loading-induced increase in cortical BV was greatest in 4-month old mice (+13%; p<0.05 vs. other ages. In summary, non-loaded female BALB/c mice exhibit an age-related decline in measures related to bone formation. Yet when subjected to tibial compression, mice from 2-12 months have an increase in cortical bone volume. Older mice respond with an upregulation of osteoblast/matrix genes, which increase to levels comparable to young mice. We conclude that mechanical loading of the tibia is anabolic for cortical bone in young and middle-aged female BALB/c mice.

  5. Dynamic intelligent cleaning model of dirty electric load data

    International Nuclear Information System (INIS)

    Zhang Xiaoxing; Sun Caixin

    2008-01-01

    There are a number of dirty data in the load database derived from the supervisory control and data acquisition (SCADA) system. Thus, the data must be carefully and reasonably adjusted before it is used for electric load forecasting or power system analysis. This paper proposes a dynamic and intelligent data cleaning model based on data mining theory. Firstly, on the basis of fuzzy soft clustering, the Kohonen clustering network is improved to fulfill the parallel calculation of fuzzy c-means soft clustering. Then, the proposed dynamic algorithm can automatically find the new clustering center (the characteristic curve of the data) with the updated sample data; At last, it is composed with radial basis function neural network (RBFNN), and then, an intelligent adjusting model is proposed to identify the dirty data. The rapid and dynamic performance of the model makes it suitable for real time calculation, and the efficiency and accuracy of the model is proved by test results of electrical load data analysis in Chongqing

  6. 40 CFR 52.2522 - Approval status.

    Science.gov (United States)

    2010-07-01

    ... plant, Monongahela Power Co. (b) The Administrator hereby extends the interim limitation of 5.12 lbs. SO2 per million BTU for the Harrison power plant until a permanent emission limitation is approved. (c...-10 NAAQS. (h) EPA disapproves the portion of 45 CSR 13 subsection 1 referencing major stationary...

  7. Nanoporous Cu-C composites based on carbon-nanotube aerogels

    Energy Technology Data Exchange (ETDEWEB)

    Charnvanichborikarn, S.; Shin, S. J.; Worsley, M. A.; Tran, I. C.; Willey, T. M.; van Buuren, T.; Felter, T. E.; Colvin, J. D.; Kucheyev, S. O. [LLNL; (Sandia)

    2013-11-22

    Current synthesis methods of nanoporous Cu–C composites offer limited control of the material composition, structure, and properties, particularly for large Cu loadings of ≳20 wt%. Here, we describe two related approaches to realize novel nanoporous Cu–C composites based on the templating of recently developed carbon-nanotube aerogels (CNT-CAs). Our first approach involves the trapping of Cu nanoparticles while CNT-CAs undergo gelation. This method yields nanofoams with relatively high densities of ≳65 mg cm-3 for Cu loadings of ≳10 wt%. Our second approach overcomes this limitation by filling the pores of undoped CNT-CA monoliths with an aqueous solution of CuSO4 followed by (i) freeze-drying to remove water and (ii) thermal decomposition of CuSO4. With this approach, we demonstrate Cu–C composites with a C matrix density of -25 mg cm-3 and Cu loadings of up to 70 wt%. These versatile methods could be extended to fabricate other nanoporous metal–carbon composite materials geared for specific applications.

  8. Cognitive Load of Learner Control: Extraneous or Germane Load?

    Directory of Open Access Journals (Sweden)

    Mieke Vandewaetere

    2013-01-01

    Full Text Available Computer-based learning environments become more tailored when learners can exert control over one or more parts of the learning process. Learner control (LC demands additional efforts of learners because, in addition to learning, they also have to monitor that learning. As a consequence, LC may cause additional cognitive load and even cognitive overload. The central question in this study is what type of cognitive load is induced by LC and whether the experienced load is related to learning outcomes. For this study, half of the students had control over task selection, while the other half had not. Within each condition, students were assigned to a single treatment, with the primary task to solely focus on the learning content, and a dual treatment, comprising a primary task and a secondary task. The results indicate that LC did not impose higher cognitive load as measured by secondary task scores and mental effort ratings.

  9. Measurements and simulations for peak electrical load reduction in cooling dominated climate

    International Nuclear Information System (INIS)

    Sadineni, Suresh B.; Boehm, Robert F.

    2012-01-01

    Peak electric demand due to cooling load in the Desert Southwest region of the US has been an issue for the electrical energy suppliers. To address this issue, a consortium has been formed between the University of Nevada Las Vegas, Pulte Homes (home builder) and NV Energy (local utility) in order to reduce the peak load by more than 65%. The implemented strategies that were used to accomplish that goal consist of energy efficiency in homes, onsite electricity generation through roof integrated PV, direct load control, and battery storage at the substation level. The simulation models developed using building energy analysis software were validated against measured data. The electrical energy demand for the upgraded home during peak period (1:00–7:00 PM) decreased by approximately 37% and 9% compared to a code standard home of the same size, due to energy efficiency and PV generation, respectively. The total decrease in electrical demand due to energy efficiency and PV generation during the peak period is 46%. Additionally, a 2.2 °C increase in thermostat temperature from 23.9 °C to 26.1 °C between 4:00 PM and 7:00 PM has further decreased the average demand during the peak period by 69% of demand from a standard home. -- Highlights: ► A study to demonstrate peak load reductions of 65% at the substation. ► A new residential energy efficient community named Villa Trieste is being developed. ► The peak demand from the homes has decreased by 37% through energy efficiency. ► A 1.8 kWp system along with energy efficiency measures decreased peak by 46%.

  10. Using squat testing to predict training loads for lower-body exercises in elite karate athletes.

    Science.gov (United States)

    Wong, Del P; Tan, Erik C H; Chaouachi, Anis; Carling, Christopher; Castagna, Carlo; Bloomfield, Jonathan; Behm, David G

    2010-11-01

    The purpose of this study was to determine the relationship between squat loads and 2 bilateral and 2 unilateral stepping lower-body exercises in predominantly unilateral movement elite athletes (Karate). Equations to predict loads for lower-body exercises based on the squat load were also determined. Fourteen male elite Karate athletes (age = 22.6 ± 1.2 years) performed 6 repetition maximum (RM) of the following free-weight bilateral exercises: back half squat, deadlift, leg press and unilateral stepping exercises, lunge; and step-up. Results showed that 6RM squat load was significantly (p squat load was a significant predictor for deadlift, leg press, lunge, and step-up (R2 range from 0.57 to 0.85, p squat load (1.12)-16.60 kg, (b) Leg press = squat load (1.66) + 16.10 kg, (c) Lunge = squat load (0.61) + 9.39 kg, and (d) step-up = squat load (0.85)-10.36 kg. Coaches and fitness professionals can use the 6RM squat load as a time effective and accurate method to predict training loads for both bilateral and unilateral lower-body exercises with quadriceps as the prime mover. Load prescriptions for unilateral exercises should take into account the type of athletic population.

  11. Acute and subacute toxicity profiles of thymoquinone-loaded nanostructured lipid carrier in BALB/c mice

    Directory of Open Access Journals (Sweden)

    Ong YS

    2016-11-01

    Full Text Available Yong Sze Ong,1 Latifah Saiful Yazan,1,2 Wei Keat Ng,1 Mustapha M Noordin,3 Sarah Sapuan,1 Jhi Biau Foo,1 Yin Sim Tor1 1Laboratory of Molecular Biomedicine, Institute of Bioscience, 2Department of Biomedical Science, Faculty of Medicine and Health Sciences, 3Department of Pathology and Veterinary Microbiology, Faculty of Veterinary Medicine, Universiti Putra Malaysia, Selangor, Malaysia Background: Thymoquinone (TQ, the predominant active lipophilic component in Nigella sativa seed oil, has a variety of pharmacological properties such as anticancer activities. However, translation of TQ to clinical phase is still not possible due to its hydrophobic properties. This problem can be solved by encapsulating it in nanoformulations to enhance its pharmacological properties. In our previous study, TQ has been successfully encapsulated in a nanostructured lipid carrier (hereinafter referred to as TQNLC with excellent physiochemical properties such as high encapsulation efficiency, high drug-loading capacity, particle diameter less than 100 nm, and stability up to 2 years. In vitro studies also proved that TQNLC exhibited antiproliferative activity toward breast and cervical cancer cell lines. However, no toxicity profile related to this formulation has been reported. In this study, we determine and compare the in vivo toxicity of both TQNLC and TQ. Materials and methods: The in vivo toxicity (acute and subacute toxicity study was carried out by oral administration of TQNLC and TQ to BALB/c mice. Animal survival, body weight, organ weight-to-body weight ratio, hematological profile, biochemistry profile, and histopathological changes were analyzed. Results: In acute toxicity, TQ that is loaded in nanostructured lipid carrier (NLC was found to be less toxic than pure TQ. It can be concluded that encapsulation of TQ in lipid carrier minimizes the toxicity of the compound. In the subacute toxicity study, oral administration of 100 mg/kg of TQNLC and TQ

  12. Influence of Mixed Mode I-Mode II Loading on Fatigue Delamination Growth Characteristics of a Graphite Epoxy Tape Laminate

    Science.gov (United States)

    Ratcliffe, James G.; Johnston, William M., Jr.

    2014-01-01

    Mixed mode I-mode II interlaminar tests were conducted on IM7/8552 tape laminates using the mixed-mode bending test. Three mixed mode ratios, G(sub II)/G(sub T) = 0.2, 0.5, and 0.8, were considered. Tests were performed at all three mixed-mode ratios under quasi-static and cyclic loading conditions, where the former static tests were used to determine initial loading levels for the latter fatigue tests. Fatigue tests at each mixed-mode ratio were performed at four loading levels, Gmax, equal to 0.5G(sub c), 0.4G(sub c), 0.3G(sub c), and 0.2G(sub c), where G(sub c) is the interlaminar fracture toughness of the corresponding mixed-mode ratio at which a test was performed. All fatigue tests were performed using constant-amplitude load control and delamination growth was automatically documented using compliance solutions obtained from the corresponding quasi-static tests. Static fracture toughness data yielded a mixed-mode delamination criterion that exhibited monotonic increase in Gc with mixed-mode ratio, G(sub II)/G(sub T). Fatigue delamination onset parameters varied monotonically with G(sub II)/G(sub T), which was expected based on the fracture toughness data. Analysis of non-normalized data yielded a monotonic change in Paris law exponent with mode ratio. This was not the case when normalized data were analyzed. Fatigue data normalized by the static R-curve were most affected in specimens tested at G(sub II)/G(sub T)=0.2 (this process has little influence on the other data). In this case, the normalized data yielded a higher delamination growth rate compared to the raw data for a given loading level. Overall, fiber bridging appeared to be the dominant mechanism, affecting delamination growth rates in specimens tested at different load levels and differing mixed-mode ratios.

  13. Missing a trick: Auditory load modulates conscious awareness in audition.

    Science.gov (United States)

    Fairnie, Jake; Moore, Brian C J; Remington, Anna

    2016-07-01

    In the visual domain there is considerable evidence supporting the Load Theory of Attention and Cognitive Control, which holds that conscious perception of background stimuli depends on the level of perceptual load involved in a primary task. However, literature on the applicability of this theory to the auditory domain is limited and, in many cases, inconsistent. Here we present a novel "auditory search task" that allows systematic investigation of the impact of auditory load on auditory conscious perception. An array of simultaneous, spatially separated sounds was presented to participants. On half the trials, a critical stimulus was presented concurrently with the array. Participants were asked to detect which of 2 possible targets was present in the array (primary task), and whether the critical stimulus was present or absent (secondary task). Increasing the auditory load of the primary task (raising the number of sounds in the array) consistently reduced the ability to detect the critical stimulus. This indicates that, at least in certain situations, load theory applies in the auditory domain. The implications of this finding are discussed both with respect to our understanding of typical audition and for populations with altered auditory processing. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  14. Lateral loadings on snubber assemblies

    International Nuclear Information System (INIS)

    Raphael, L.S.

    1981-01-01

    This paper examines the installation of snubber assemblies in power plants with respect to transverse or lateral loads as well as axial loads. Evaluation of the effects of low level, lateral loads was performed by analytical means. At higher loadings, the snubber assembly could no longer be treated as a column; therefore, the effects of lateral loadings was determined by test. The test consisted of applying both lateral and axial loads simultaneously. Results of both the analysis and the test showed that the application of lateral loads had a considerable effect on the snubber assemblies

  15. The relationship between loads and power of a rotor and an actuator disc

    International Nuclear Information System (INIS)

    Van Kuik, Gijs A M

    2014-01-01

    Most state of the art rotor design methods are based on the actuator disc theory developed about one century ago. The actuator disc is an axisymmetric permeable surface carrying a load that represents the load on a real rotor with a finite number of blades N. However, the mathematics of the transition from a real rotor load to an axisymmetrically loaded disc is not yet presented in literature. By formulating an actuator disc equation of motion in which the Bernoulli constant H is expressed in kinematical terms, a comparison of the power conversion and load on the disc and rotor is possible. For both the converted power is expressed as a change of angular momentum times rotational speed. The limits for N → ∞ while the chord c → 0, the rotational speed Ω → ∞, the load F becoming uniform by ∂F/∂r → 0 and the thickness ε → 0 confirm that the classical disc represents the rotor with an infinite number of blades. Furthermore, the expressions for the blade load are compared to the expressions in current design and analysis tools. The latter do not include the load on chord-wise vorticity. Including this is expected to give a better modelling of the tip and root flow

  16. The relationship between loads and power of a rotor and an actuator disc

    Science.gov (United States)

    van Kuik, Gijs A. M.

    2014-12-01

    Most state of the art rotor design methods are based on the actuator disc theory developed about one century ago. The actuator disc is an axisymmetric permeable surface carrying a load that represents the load on a real rotor with a finite number of blades N. However, the mathematics of the transition from a real rotor load to an axisymmetrically loaded disc is not yet presented in literature. By formulating an actuator disc equation of motion in which the Bernoulli constant H is expressed in kinematical terms, a comparison of the power conversion and load on the disc and rotor is possible. For both the converted power is expressed as a change of angular momentum times rotational speed. The limits for N → ∞ while the chord c → 0, the rotational speed Ω → ∞, the load F becoming uniform by ∂F/∂r → 0 and the thickness epsilon → 0 confirm that the classical disc represents the rotor with an infinite number of blades. Furthermore, the expressions for the blade load are compared to the expressions in current design and analysis tools. The latter do not include the load on chord-wise vorticity. Including this is expected to give a better modelling of the tip and root flow.

  17. The Effect of Resistance Training on Levels of Interlukine-6 and High-Sensitivity C - reactive protein in Older-Aged Women

    Directory of Open Access Journals (Sweden)

    Zahra Mardanpour Shahrekordi

    2017-06-01

    Full Text Available Introduction: Aging is associated with elevated levels of some proinflammatory factors and exercise is a non-invasive intervention to improve immune function among older adults .The aim of the study was to compare resistance training effects on interlukine-6 (IL-6 and high-sensitivity C-reactive protein (hs-CRP levels in older-aged women. Methods: The study was quasi-experimental and forty healthy females were selected and randomly assigned to one of four groups: strength after endurance training (endurance + strength (E + S, n = 9, strength prior to endurance training (strength + endurance (S + E, n = 10, interval resistance-endurance training (Int, n = 12, and control (n = 9 groups. The training program was performed for eight weeks, three times per week. Human TNF-α and IL-6 sandwich ELISA Kit were used. Within-group differences were analyzed using a paired samples t-test and between-group differences were analyzed using one-way analysis of variance. Results: The intra-session order had not significantly influence on the adaptive response of waist-to-hip ratio (p = 0.55, IL-6 (p = 0.55 and hs-CRP (p = 0.55 throughout the study. However, significant differences were shown following combined training between the S + E, E + S and Int groups for Vo2 max (p = 0.029, body mass (p = 0.016 and BMI (p = 0.023 when comparing pre and posttests. Conclusion: This study confirmed that adaptations to a combination of endurance and resistance training appear to be independent of whether resistance training occurs prior to or following endurance training.

  18. Cognitive Load and Cooperation

    DEFF Research Database (Denmark)

    Døssing, Felix Sebastian; Piovesan, Marco; Wengström, Erik Roland

    2017-01-01

    We study the effect of intuitive and reflective processes on cooperation using cognitive load. Compared with time constraint, which has been used in the previous literature, cognitive load is a more direct way to block reflective processes, and thus a more suitable way to study the link between...... intuition and cooperation. Using a repeated public goods game, we study the effect of different levels of cognitive load on contributions. We show that a higher cognitive load increases the initial level of cooperation. In particular, subjects are significantly less likely to fully free ride under high...... cognitive load....

  19. Fracture behaviour of steel 20 MnMoNi 5 5 under stress wave loading

    International Nuclear Information System (INIS)

    Clos, R.; Schreppel, U.; Veit, P.; Zencker, U.; Specht, E.

    1994-01-01

    Crack initiation in fine grained 20 MnMoNi 5 5 steel has been investigated under stress wave loading conditions in the temperature range from -50 C to 20 C by a loading setup similar the ''Split Hopkinson Pressure Bar'' technique. For temperatures up to 20 C, fracture occurs by cleavage and K Id approaches and falls below the reference fracture toughness, while at room temperature stable crack growth occurs with a J i close to the static initiation value of the J-integral. The analysis of the crack tip configuration suggests that stable crack growth is the result of the following simultaneously induced stochastical processes: generation of constrained local microcracks, blunting of the individual crack tips and the deformation of material bridges at different regions along the crack tip front. (orig.)

  20. Synthesis and fluorescence of new 3-biphenylpyrrolo[1,2-c]pyrimidines

    Directory of Open Access Journals (Sweden)

    Marian-Laurentiu Tatu

    2017-07-01

    Full Text Available New pyrrolo[1,2-c]pyrimidines derivates having a biphenyl moiety at position 3 have been synthesized by 1,3-dipolar cycloaddition of their corresponding N-ylides with activated alkynes. FTIR, 1H and 13C NMR spectroscopy and elemental analysis have been used to characterize the structures of the new nine pyrrolo[1,2-c]pyrimidine derivates. Absorption and fluorescence spectra have been recorded. The appropriate solvent for the photoluminescence properties of the studied compounds has been found to be chloroform:acetonitrile mixture (1:1. The main spectral features such as molar extinction coefficients (ε, Stokes shifts, quantum yields using quinine sulphate as standard, fluorescence quenching in the presence of benzoquinone and Stern-Volmer constants have been calculated. The substituent effects on intensity of absorption, maximum absorbance wavelengths and fluorescence parameters have been discussed. The highest quantum yield value was found for ethyl 3-(4-biphenylyl-7-(3,4-dimethoxybenzoylpyrrolo[1,2-c]pyrimidine-5-carboxylate (0.55. The obtained results suggest that the studied compounds are promising candidates for future study in order to evaluate their use in practical applications in fluorescent chemical sensors.