WorldWideScience

Sample records for load control strategies

  1. Aerodynamic load control strategy of wind turbine in microgrid

    Science.gov (United States)

    Wang, Xiangming; Liu, Heshun; Chen, Yanfei

    2017-12-01

    A control strategy is proposed in the paper to optimize the aerodynamic load of the wind turbine in micro-grid. In grid-connection mode, the wind turbine adopts a new individual variable pitch control strategy. The pitch angle of the blade is rapidly given by the controller, and the pitch angle of each blade is fine tuned by the weight coefficient distributor. In islanding mode, according to the requirements of energy storage system, a given power tracking control method based on fuzzy PID control is proposed. Simulation result shows that this control strategy can effectively improve the axial aerodynamic load of the blade under rated wind speed in grid-connection mode, and ensure the smooth operation of the micro-grid in islanding mode.

  2. Climate Control Load Reduction Strategies for Electric Drive Vehicles in Warm Weather

    Energy Technology Data Exchange (ETDEWEB)

    Jeffers, M. A.; Chaney, L.; Rugh, J. P.

    2015-04-30

    Passenger compartment climate control is one of the largest auxiliary loads on a vehicle. Like conventional vehicles, electric vehicles (EVs) require climate control to maintain occupant comfort and safety, but cabin heating and air conditioning have a negative impact on driving range for all electric vehicles. Range reduction caused by climate control and other factors is a barrier to widespread adoption of EVs. Reducing the thermal loads on the climate control system will extend driving range, thereby reducing consumer range anxiety and increasing the market penetration of EVs. Researchers at the National Renewable Energy Laboratory have investigated strategies for vehicle climate control load reduction, with special attention toward EVs. Outdoor vehicle thermal testing was conducted on two 2012 Ford Focus Electric vehicles to evaluate thermal management strategies for warm weather, including solar load reduction and cabin pre-ventilation. An advanced thermal test manikin was used to assess a zonal approach to climate control. In addition, vehicle thermal analysis was used to support testing by exploring thermal load reduction strategies, evaluating occupant thermal comfort, and calculating EV range impacts. Through stationary cooling tests and vehicle simulations, a zonal cooling configuration demonstrated range improvement of 6%-15%, depending on the drive cycle. A combined cooling configuration that incorporated thermal load reduction and zonal cooling strategies showed up to 33% improvement in EV range.

  3. Optimized Control Strategy For Over Loaded Offshore Wind Turbines

    DEFF Research Database (Denmark)

    Odgaard, Peter Fogh; Knudsen, Torben; Wisniewski, Rafal

    2015-01-01

    controller tuning for a given wind turbine. It also enables a very safe and robust comparison between a new control strategy and the present one. Main body of abstract Is it true that power de-rating indeed the best way to reduce loads? The power de-rating approach has the drawback of only indirectly...

  4. Research on Operation and Control Strategy of 600MW PWR in Load Follow

    Energy Technology Data Exchange (ETDEWEB)

    Qu, Bing Yang; Cao, Xin Rong [Harbin Engineering University, Harbin (China); Li, Han Chen [China Nuclear Power Engineering Co., Beijing (China)

    2014-08-15

    600MW Pressurized Water Reactor (PWR) is designed to operate in Constant Axial Offset Control (CAOC) strategy with base load originally. By calculations over a typical load follow scenario '12-3-6-3 {sup (}100-50-100%FP) via the CASMO-4E and SIMULATE-3 package, values of core operating parameter have been examined. With the progress of the nuclear power industry, advanced reactors are considered to have a good performance in load follow, economy and flexibility. Under the premise of fuel loading and structural dimensions unchanged, two independent control rod groups M and AO are used in 600MW pressurized water reactor to provide fine control of both the core reactivity and axial power distribution, which is named ' Improved G strategy .' The influences of different control rod distributions, composition materials, and overlap steps had in power changes have been examined in a comparative study to choose the optimal one.Then we simulate a range of load follow scenarios of the redesigned 600MW core without adjusting soluble boron concentration in the begin, middle and end of first cycle. This paper additionally demonstrated the moderator temperature coefficient and shutdown margin values of the reactor in Improved G strategy to compare with the thermal safety design criteria. It's demonstrated that adequate adjustment of control rod groups enable the core to perform load follow through Improved G strategy in 80% of cycle and save a large volume of liquid effluent particularly toward the end of cycle.

  5. Selecting a Control Strategy for Plug and Process Loads

    Energy Technology Data Exchange (ETDEWEB)

    Lobato, C.; Sheppy, M.; Brackney, L.; Pless, S.; Torcellini, P.

    2012-09-01

    Plug and Process Loads (PPLs) are building loads that are not related to general lighting, heating, ventilation, cooling, and water heating, and typically do not provide comfort to the building occupants. PPLs in commercial buildings account for almost 5% of U.S. primary energy consumption. On an individual building level, they account for approximately 25% of the total electrical load in a minimally code-compliant commercial building, and can exceed 50% in an ultra-high efficiency building such as the National Renewable Energy Laboratory's (NREL) Research Support Facility (RSF) (Lobato et al. 2010). Minimizing these loads is a primary challenge in the design and operation of an energy-efficient building. A complex array of technologies that measure and manage PPLs has emerged in the marketplace. Some fall short of manufacturer performance claims, however. NREL has been actively engaged in developing an evaluation and selection process for PPLs control, and is using this process to evaluate a range of technologies for active PPLs management that will cap RSF plug loads. Using a control strategy to match plug load use to users' required job functions is a huge untapped potential for energy savings.

  6. Climate Control Load Reduction Strategies for Electric Drive Vehicles in Cold Weather: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Jeffers, Matthew; Chaney, Lawrence; Rugh, John

    2016-03-31

    When operated, the climate control system is the largest auxiliary load on a vehicle. This load has significant impact on fuel economy for conventional and hybrid vehicles, and it drastically reduces the driving range of all electric vehicles (EVs). Heating is even more detrimental to EV range than cooling because no engine waste heat is available. Reducing the thermal loads on the heating, ventilating, and air conditioning system will extend driving range and increase the market penetration of EVs. Researchers at the National Renewable Energy Laboratory have evaluated strategies for vehicle climate control load reduction with special attention toward grid connected electric vehicles. Outdoor vehicle thermal testing and computational modeling were used to assess potential strategies for improved thermal management and to evaluate the effectiveness of thermal load reduction technologies. A human physiology model was also used to evaluate the impact on occupant thermal comfort. Experimental evaluations of zonal heating strategies demonstrated a 5.5% to 28.5% reduction in cabin heating energy over a 20-minute warm-up. Vehicle simulations over various drive cycles show a 6.9% to 18.7% improvement in EV range over baseline heating using the most promising zonal heating strategy investigated. A national-level analysis was conducted to determine the overall national impact. If all vehicles used the best zonal strategy, the range would be improved by 7.1% over the baseline heating range. This is a 33% reduction in the range penalty for heating.

  7. Power flow control strategy in distribution network for dc type distributed energy resource at load bus

    International Nuclear Information System (INIS)

    Hanif, A.; Choudhry, M.A.

    2013-01-01

    This research work presents a feed forward power flow control strategy in the secondary distribution network working in parallel with a DC type distributed energy resource (DER) unit with SPWM-IGBT Voltage Source Converter (VSC). The developed control strategy enables the VSC to be used as power flow controller at the load bus in the presence of utility supply. Due to the investigated control strategy, power flow control from distributed energy resource (DER) to common load bus is such that power flows to the load without facing any power quality problem. The technique has an added advantage of controlling power flow without having a dedicated power flow controller. The SPWM-IGBT VSC is serving the purpose of dc-ac converter as well as power flow controller. Simulations for a test system using proposed power flow control strategy are carried out using SimPower Systems toolbox of MATLAB at the rate and Simulink at the rate. The results show that a reliable, effective and efficient operation of DC type DER unit in coordination with main utility network can be achieved. (author)

  8. Comparison of individual pitch and smart rotor control strategies for load reduction

    International Nuclear Information System (INIS)

    Plumley, C; Leithead, W; Jamieson, P; Bossanyi, E; Graham, M

    2014-01-01

    Load reduction is increasingly seen as an essential part of controller and wind turbine design. On large multi-MW wind turbines that experience high levels of wind shear and turbulence across the rotor, individual pitch control and smart rotor control are being considered. While individual pitch control involves adjusting the pitch of each blade individually to reduce the cyclic loadings on the rotor, smart rotor control involves activating control devices distributed along the blades to alter the local aerodynamics of the blades. Here we investigate the effectiveness of using a DQ-axis control and a distributed (independent) control for both individual pitch and trailing edge flap smart rotor control. While load reductions are similar amongst the four strategies across a wide range of variables, including blade root bending moments, yaw bearing and shaft, the pitch actuator requirements vary. The smart rotor pitch actuator has reduced travel, rates, accelerations and power requirements than that of the individual pitch controlled wind turbines. This benefit alone however would be hard to justify the added design complexities of using a smart rotor, which can be seen as an alternative to upgrading the pitch actuator and bearing. In addition, it is found that the independent control strategy is apt at roles that the collective pitch usually targets, such as tower motion and speed control, and it is perhaps here, in supplementing other systems, that the future of the smart rotor lies

  9. Comparison of individual pitch and smart rotor control strategies for load reduction

    Science.gov (United States)

    Plumley, C.; Leithead, W.; Jamieson, P.; Bossanyi, E.; Graham, M.

    2014-06-01

    Load reduction is increasingly seen as an essential part of controller and wind turbine design. On large multi-MW wind turbines that experience high levels of wind shear and turbulence across the rotor, individual pitch control and smart rotor control are being considered. While individual pitch control involves adjusting the pitch of each blade individually to reduce the cyclic loadings on the rotor, smart rotor control involves activating control devices distributed along the blades to alter the local aerodynamics of the blades. Here we investigate the effectiveness of using a DQ-axis control and a distributed (independent) control for both individual pitch and trailing edge flap smart rotor control. While load reductions are similar amongst the four strategies across a wide range of variables, including blade root bending moments, yaw bearing and shaft, the pitch actuator requirements vary. The smart rotor pitch actuator has reduced travel, rates, accelerations and power requirements than that of the individual pitch controlled wind turbines. This benefit alone however would be hard to justify the added design complexities of using a smart rotor, which can be seen as an alternative to upgrading the pitch actuator and bearing. In addition, it is found that the independent control strategy is apt at roles that the collective pitch usually targets, such as tower motion and speed control, and it is perhaps here, in supplementing other systems, that the future of the smart rotor lies.

  10. A New V2G Control Strategy for Load Factor Improvement Using Smoothing Technique

    Directory of Open Access Journals (Sweden)

    CHANHOM, P.

    2017-08-01

    Full Text Available This paper proposes a new vehicle-to-grid (V2G control strategy for improving the load factor in the power network. To operate the proposed strategy, the available storage capacity of the PEVs’ batteries is considered as a battery energy storage system (BESS for charging and discharging an amount of power corresponding to the V2G power command. Due to the remarkable advantages of the technique so-called simple moving average, it is selected for applying in the proposed V2G control strategy. In this research, for investigating the load factor improvement, the essential data including the daily-load profiles with 7-day and 14-day periods are used for the 3 studied cases. These 3 studied cases present the power network with variation of the PEVs locations for describing the PEVs usage and charging or discharging behavior. The performance of the proposed strategy is simulated and verified by the MATPOWER software. The simulation results show that the load factors of the 3 studied cases are improved. Moreover, the encouragement of energy arbitrage for the PEVs owners is also discussed in this paper.

  11. Voltage Stability Control of Electrical Network Using Intelligent Load Shedding Strategy Based on Fuzzy Logic

    Directory of Open Access Journals (Sweden)

    Houda Jouini

    2010-01-01

    Full Text Available As a perspective to ensure the power system stability and to avoid the vulnerability leading to the blackouts, several preventive and curative means are adopted. In order to avoid the voltage collapse, load shedding schemes represent a suitable action to maintain the power system service quality and to control its vulnerability. In this paper, we try to propose an intelligent load shedding strategy as a new approach based on fuzzy controllers. This strategy was founded on the calculation of generated power sensitivity degree related to those injected at different network buses. During the fault phase, fuzzy controller algorithms generate monitor vectors ensuring a precalculated load shedding ratio in the purpose to reestablish the power balance and conduct the network to a new steady state.

  12. An Optimal PR Control Strategy with Load Current Observer for a Three-Phase Voltage Source Inverter

    Directory of Open Access Journals (Sweden)

    Xiaobo Dou

    2015-07-01

    Full Text Available Inverter voltage control is an important task in the operation of a DC/AC microgrid system. To improve the inverter voltage control dynamics, traditional approaches attempt to measure and feedforward the load current, which, however, needs remote measurement with communications in a microgrid system with distributed loads. In this paper, a load current observer (LCO based control strategy, which does not need remote measurement, is proposed for sinusoidal signals tracking control of a three-phase inverter of the microgrid. With LCO, the load current is estimated precisely, acting as the feedforward of the dual-loop control, which can effectively enlarge the stability margin of the control system and improve the dynamic response to load disturbance. Furthermore, multiple PR regulators are applied in this strategy conducted in a stationary  frame to suppress the transient fluctuations and the total harmonic distortion (THD of the output voltage and achieve faster transient performance compared with traditional dual-loop control in a rotating dq0 frame under instantaneous change of various types of load (i.e., balanced load, unbalanced load, and nonlinear load. The parameters of multiple PR regulators are analyzed and selected through the root locus method and the stability of the whole control system is evaluated and analyzed. Finally, the validity of the proposed approach is verified through simulations and a three-phase prototype test system with a TMS320F28335 DSP.

  13. Load frequency control strategies: A state-of-the-art survey for the researcher

    International Nuclear Information System (INIS)

    Shayeghi, H.; Shayanfar, H.A.; Jalili, A.

    2009-01-01

    Global analysis of the power system markets shows that load frequency control (LFC) is one of the most profitable ancillary services of these systems. This service is related to the short-term balance of energy and frequency of the power systems and acquires a principal role to enable power exchanges and to provide better conditions for electricity trading. The main goal of the LFC problem is to maintain zero steady-state errors for frequency deviation and good tracking of load demands in a multi-area power system. This paper provides an overview of control strategies for researchers, as well as of their current use in the field of LFC problems. The history of control strategies is outlined. Various control methodologies based on the classical and optimal control, robust, adaptive, self-tuning control, VSC systems, digital and artificial intelligent/soft computing control techniques are discussed. We make various comparisons between these approaches, and the main advantages and disadvantages of the methods are presented. Finally, the investigations of the LFC problem incorporating BES/SMES, wind turbines and FACTs devices have also been discussed. (author)

  14. Strategies for Controlling Plug Loads. A Tool for Reducing Plug Loads in Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Torcellini, Paul [National Renewable Energy Lab. (NREL), Golden, CO (United States); Bonnema, Eric [National Renewable Energy Lab. (NREL), Golden, CO (United States); Sheppy, Michael [National Renewable Energy Lab. (NREL), Golden, CO (United States); Pless, Shanti [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2015-09-01

    Plug loads are often not considered as part of the energy savings measures in Commercial Buildings; however, they can account for up to 50% of the energy used in the building. These loads are numerous and often scattered throughout a building. Some of these loads are purchased by the owner and some designed into the building or the tenant finishes for a space. This document provides a strategy and a tool for minimizing these loads.

  15. New fuel air control strategy for reducing NOx emissions from corner-fired utility boilers at medium-low loads

    DEFF Research Database (Denmark)

    Zhao, Sinan; Fang, Qingyan; Yin, Chungen

    2017-01-01

    Due to the rapidly growing renewable power, the fossil fuel power plants have to be increasingly operated under large and rapid load change conditions, which can induce various challenges. This work aims to reduce NOx emissions of large-scale corner-fired boilers operated at medium–low loads....... The combustion characteristics and NOx emissions from a 1000 MWe corner-fired tower boiler under different loads are investigated experimentally and numerically. A new control strategy for the annular fuel air is proposed and implemented in the boiler, in which the secondary air admitted to the furnace through...... the air annulus around each coal nozzle tip is controlled by the boiler load, instead of being controlled by the output of the connected mill as commonly used in this kind of power plant. Both the experimental and simulation results show that the new control strategy reduces NOx emissions at the entrance...

  16. The effect of utility time-varying pricing and load control strategies on residential summer peak electricity use. A review

    International Nuclear Information System (INIS)

    Newsham, Guy R.; Bowker, Brent G.

    2010-01-01

    Peak demand for electricity in North America is expected to grow, challenging electrical utilities to supply this demand in a cost-effective, reliable manner. Therefore, there is growing interest in strategies to reduce peak demand by eliminating electricity use, or shifting it to non-peak times. This strategy is commonly called 'demand response'. In households, common strategies are time-varying pricing, which charge more for energy use on peak, or direct load control, which allows utilities to curtail certain loads during high demand periods. We reviewed recent North American studies of these strategies. The data suggest that the most effective strategy is a critical peak price (CPP) program with enabling technology to automatically curtail loads on event days. There is little evidence that this causes substantial hardship for occupants, particularly if they have input into which loads are controlled and how, and have an override option. In such cases, a peak load reduction of at least 30% is a reasonable expectation. It might be possible to attain such load reductions without enabling technology by focusing on household types more likely to respond, and providing them with excellent support. A simple time-of-use (TOU) program can only expect to realise on-peak reductions of 5%. (author)

  17. Comparison of loads for wind turbine down-regulation strategies

    DEFF Research Database (Denmark)

    Zhu, Jiangsheng; Ma, Kuichao; N. Soltani, Mohsen

    2017-01-01

    For wind farm active power setpoint tracking, both farm level and turbine level down regulation strategies should to be optimized. Several down regulation strategies are chosen to analyse the wind turbine load performance according to different wind speed and power reference. In this paper we...... suggest appropriate down regulation strategy to control wind turbine for active power reference tracking. we compare four different control strategies, namely Const-Ω, Const-λ, Max-Ω and Min-Ct and discuss the loads on main components and downwind speed by presenting analysis of several wind scenarios...

  18. Control Strategy for Vehicle Inductive Wireless Charging Based on Load Adaptive and Frequency Adjustment

    Directory of Open Access Journals (Sweden)

    Shichun Yang

    2018-05-01

    Full Text Available Wireless charging system for electric vehicles is a hot research issue in the world today. Since the existing research on wireless charging is mostly forward-looking aimed at low-power appliances like household appliances, while electric vehicles need a high-power, high-efficiency, and strong coupling wireless charging system. In this paper, we have specifically designed a 6.6 KW wireless charging system for electric vehicles and have proposed a control strategy suitable for electric vehicles according to its power charging characteristics and existing common wired charging protocol. Firstly, the influence of the equivalent load and frequency bifurcation on a wireless charging system is analyzed in this paper. Secondly, an adaptive load control strategy matching the characteristics of the battery, and the charging pile is put forward to meet the constant current and constant voltage charging requirements to improve the system efficiency. In addition, the frequency adjustment control strategy is designed to realize the real-time dynamic optimization of the entire system. It utilizes the improved methods of rapid judgment, variable step length matching and frequency splitting recognition, which are not adopted in early related researches. Finally, the results of 6.6 kW test show that the control strategy works perfectly since system response time can be reduced to less than 1 s, and the overall efficiency of the wireless charging system and the grid power supply module can reach up to 91%.

  19. A comparison of Reactivity Controlled Compression Ignition (RCCI) and Gasoline Compression Ignition (GCI) strategies at high load, low speed conditions

    International Nuclear Information System (INIS)

    Kavuri, Chaitanya; Paz, Jordan; Kokjohn, Sage L.

    2016-01-01

    Highlights: • Targeting high load-low speed, optimizations of RCCI and GCI strategies were performed. • The two strategies were compared in terms of performance, controllability and stability. • The optimum cases had high gross indicated efficiency (∼47%) and low NOx emissions. • RCCI strategy showed better combustion control but had higher soot emissions. • GCI strategy was relatively more sensitive to fluctuations in charge conditions. - Abstract: Past research has shown that Reactivity Controlled Compression Ignition (RCCI) and Gasoline Compression Ignition (GCI) combustion are promising approaches to improve efficiency and reduce pollutant emissions. However, the benefits have generally been confined to mid-load operating conditions. To enable practical application, these approaches must be able to operate over the entire engine map. A particularly challenging area is high load, low speed operation. Accordingly, the present work uses detailed CFD modeling and engine experiments to compare RCCI and GCI combustion strategies at a high load, low speed condition. Computational optimizations of RCCI and GCI combustion were performed at 20 bar gross indicated mean effective pressure (IMEP) and 1300 rev/min. The optimum points from the two combustion strategies were verified using engine experiments and were used to make the comparisons between RCCI and GCI combustion. The comparison showed that both the strategies had very similar combustion characteristics with a near top dead center injection initiating combustion. A parametric study was performed to identify the key input parameters that control combustion for the RCCI and GCI strategies. For both strategies, the combustion phasing could be controlled by the start of injection (SOI) timing of the near TDC injection. The short ignition delay of diesel fuel gave the RCCI strategy better control over combustion than the GCI strategy, but also had a simultaneous tradeoff with soot emissions. With the GCI

  20. A Closed-Loop Control Strategy for Air Conditioning Loads to Participate in Demand Response

    Directory of Open Access Journals (Sweden)

    Xiaoqing Hu

    2015-08-01

    Full Text Available Thermostatically controlled loads (TCLs, such as air conditioners (ACs, are important demand response resources—they have a certain heat storage capacity. A change in the operating status of an air conditioner in a small range will not noticeably affect the users’ comfort level. Load control of TCLs is considered to be equivalent to a power plant of the same capacity in effect, and it can significantly reduce the system pressure to peak load shift. The thermodynamic model of air conditioning can be used to study the aggregate power of a number of ACs that respond to the step signal of a temperature set point. This paper analyzes the influence of the parameters of each AC in the group to the indoor temperature and the total load, and derives a simplified control model based on the two order linear time invariant transfer function. Then, the stability of the model and designs its Proportional-Integral-Differential (PID controller based on the particle swarm optimization (PSO algorithm is also studied. The case study presented in this paper simulates both scenarios of constant ambient temperature and changing ambient temperature to verify the proposed transfer function model and control strategy can closely track the reference peak load shifting curves. The study also demonstrates minimal changes in the indoor temperature and the users’ comfort level.

  1. Development of a vehicle load control strategy for Malawi for the period 2016 to 2020

    CSIR Research Space (South Africa)

    Roux, MP

    2016-07-01

    Full Text Available Strategy and development of a five-year implementation plan for significantly improving the Directorate’s current capacity to effectively manage and enforce axle load control. Specific objectives were to: a) Assist the DRTSS to undertake an extensive...

  2. Wind Farm Active Power Dispatch for Output Power Maximizing Based on a Wind Turbine Control Strategy for Load Minimizing

    DEFF Research Database (Denmark)

    Zhang, Baohua; Hu, Weihao; Hou, Peng

    2015-01-01

    Inclusion of the wake effect in the wind farm control design (WF) can increase the total captured power by wind turbines (WTs), which is usually implemented by derating upwind WTs. However, derating the WT without a proper control strategy will increase the structural loads, caused by operation...... in stall mode. Therefore, the WT control strategy for derating operation should be considered in the attempt at maximizing the total captured power while reducing structural loads. Moreover, electrical power loss on the transmission system inside a WF is also not negligible for maximizing the total output...... power of the WF. In this paper, an optimal active power dispatch strategy based on a WT derating strategy and considering the transmission loss is proposed for maximizing the total output power. The active power reference of each WT is chosen as the optimization variable. A partial swarm optimizing...

  3. Compressor Load Stand: Commissioning and Control Strategies

    National Research Council Canada - National Science Library

    Causey, Andrew

    1998-01-01

    .... The purpose of this research project was to commission this load stand, which includes setting up the hardware, setting up a control system, a data acquisition system, and an automatic test sequence system...

  4. Fully-distributed Load Frequency Control Strategy in an Islanded Microgrid Considering Plug-In Electric Vehicles

    Directory of Open Access Journals (Sweden)

    Xiao Qi

    2018-06-01

    Full Text Available With large-scale integration of electric vehicles, this paper investigates the load frequency control problem in an islanded microgrid with plug-in electric vehicles (PEVs, which can be regarded as mobile battery energy storages to provide a valuable contribution to frequency regulation. A novel fully-distributed control strategy is proposed to achieve fast frequency regulation of islanded microgrids and effective coordination control of distributed energy sources. Firstly, distributed control based on an improved linear active disturbance rejection algorithm is realized through a multi-agent system, and it greatly enhances the anti-disturbance capability of the microgrid. Then, in order to guarantee the effectiveness of PEVs in frequency regulation, PEVs are controlled following the controllable power rate (CPR calculated from the consensus-based multi-agent system. Furthermore, the system control construction in this paper is well designed to avoid the negative effects caused by system communication time delay. Finally, numerical simulations under different disturbances are carried out to demonstrate the effectiveness of the proposed control strategy in comparison with other previous control strategies.

  5. Controllable Load Management Approaches in Smart Grids

    Directory of Open Access Journals (Sweden)

    Jingshuang Shen

    2015-10-01

    Full Text Available With rapid smart grid technology development, the customer can actively participate in demand-side management (DSM with the mutual information communication between the distributor operation company and the smart devices in real-time. Controllable load management not only has the advantage of peak shaving, load balance, frequency regulation, and voltage stability, but is also effective at providing fast balancing services to the renewable energy grid in the distributed power system. The load management faces an enormous challenge as the customer has a large number of both small residential loads and dispersed renewable sources. In this paper, various controllable load management approaches are discussed. The traditional controllable load approaches such as the end users’ controllable appliances, storage battery, Vehicle-to-Grid (V2G, and heat storage are reviewed. The “broad controllable loads” management, such as the microgrid, Virtual Power Plant (VPP, and the load aggregator are also presented. Furthermore, the load characteristics, control strategies, and control effectiveness are analyzed.

  6. Peak load shifting control using different cold thermal energy storage facilities in commercial buildings: A review

    International Nuclear Information System (INIS)

    Sun, Yongjun; Wang, Shengwei; Xiao, Fu; Gao, Diance

    2013-01-01

    Highlights: • Little study reviews the load shifting control using different facilities. • This study reviews load shifting control using building thermal mass. • This study reviews load shifting control using thermal energy storage systems. • This study reviews load shifting control using phase change material. • Efforts for developing more applicable load shifting control are addressed. - Abstract: For decades, load shifting control, one of most effective peak demand management methods, has attracted increasing attentions from both researchers and engineers. Different load shifting control strategies have been developed when diverse cold thermal energy storage facilities are used in commercial buildings. The facilities include building thermal mass (BTM), thermal energy storage system (TES) and phase change material (PCM). Little study has systematically reviewed these load shifting control strategies and therefore this study presents a comprehensive review of peak load shifting control strategies using these thermal energy storage facilities in commercial buildings. The research and applications of the load shifting control strategies are presented and discussed. The further efforts needed for developing more applicable load shifting control strategies using the facilities are also addressed

  7. H∞ Based Control for Load Mitigation in Wind Turbines

    Directory of Open Access Journals (Sweden)

    Aron Pujana-Arrese

    2012-04-01

    Full Text Available This article demonstrates a strategy to design multivariable and multi-objective controllers based on the H∞ norm reduction applied to a wind turbine. The wind turbine model has been developed in the GH Bladed software and it is based on a 5 MW wind turbine defined in the Upwind European project. The designed control strategy works in the above rated power production zone and performs generator speed control and load reduction on the drive train and tower. In order to do this, two robust H∞ MISO (Multi-Input Single-Output controllers have been developed. These controllers generate collective pitch angle and generator torque set-point values to achieve the imposed control objectives. Linear models obtained in GH Bladed 4.0 are used, but the control design methodology can be used with linear models obtained from any other modelling package. Controllers are designed by setting out a mixed sensitivity problem, where some notch filters are also included in the controller dynamics. The obtained H∞ controllers have been validated in GH Bladed and an exhaustive analysis has been carried out to calculate fatigue load reduction on wind turbine components, as well as to analyze load mitigation in some extreme cases. The analysis compares the proposed control strategy based on H∞ controllers to a baseline control strategy designed using the classical control methods implemented on the present wind turbines.

  8. Operational Strategy of CBPs for load balancing of Operators in Advanced Main Control Room

    International Nuclear Information System (INIS)

    Kim, Seunghwan; Kim, Yochan; Jung, Wondea

    2014-01-01

    With the using of a computer-based control room in an APR1400 (Advanced Pressurized Reactor-1400), the operators' behaviors in the main control room had changed. However, though the working environment of operators has been changed a great deal, digitalized interfaces can also change the cognitive tasks or activities of operators. First, a shift supervisor (SS) can confirm/check the conduction of the procedures and the execution of actions of board operators (BOs) while confirming directly the operation variables without relying on the BOs. Second, all operators added to their work the use of a new CBP and Soft Controls, increasing their procedural workload. New operational control strategies of CBPs are necessary for load balancing of operator's task load in APR1400. In this paper, we compared the workloads of operators in an APR1400 who work with two different usages of the CBP. They are SS oriented usage and SS-BO collaborative usage. In this research, we evaluated the workloads of operators in an advanced main control room by the COCOA method. Two types of CBP usages were defined and the effects of these usages on the workloads were investigated. The obtained results showed that the workloads between operators in a control room can be balanced according to the CBP usages by assigning control authority to the operators

  9. Operational Strategy of CBPs for load balancing of Operators in Advanced Main Control Room

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seunghwan; Kim, Yochan; Jung, Wondea [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-05-15

    With the using of a computer-based control room in an APR1400 (Advanced Pressurized Reactor-1400), the operators' behaviors in the main control room had changed. However, though the working environment of operators has been changed a great deal, digitalized interfaces can also change the cognitive tasks or activities of operators. First, a shift supervisor (SS) can confirm/check the conduction of the procedures and the execution of actions of board operators (BOs) while confirming directly the operation variables without relying on the BOs. Second, all operators added to their work the use of a new CBP and Soft Controls, increasing their procedural workload. New operational control strategies of CBPs are necessary for load balancing of operator's task load in APR1400. In this paper, we compared the workloads of operators in an APR1400 who work with two different usages of the CBP. They are SS oriented usage and SS-BO collaborative usage. In this research, we evaluated the workloads of operators in an advanced main control room by the COCOA method. Two types of CBP usages were defined and the effects of these usages on the workloads were investigated. The obtained results showed that the workloads between operators in a control room can be balanced according to the CBP usages by assigning control authority to the operators.

  10. Systems and methods for providing power to a load based upon a control strategy

    Science.gov (United States)

    Perisic, Milun; Kajouke, Lateef A; Ransom, Ray M

    2013-12-24

    Systems and methods are provided for an electrical system. The electrical system includes a load, an interface configured to receive a voltage from a voltage source, and a controller configured to receive the voltage from the voltage source through the interface and to provide a voltage and current to the load. Wherein, when the controller is in a constant voltage mode, the controller provides a constant voltage to the load, when the controller is in a constant current mode, the controller provides a constant current to the load, and when the controller is in a constant power mode, the controller provides a constant power to the load.

  11. Load-redistribution strategy based on time-varying load against cascading failure of complex network

    International Nuclear Information System (INIS)

    Liu Jun; Shi Xin; Wang Kai; Shi Wei-Ren; Xiong Qing-Yu

    2015-01-01

    Cascading failure can cause great damage to complex networks, so it is of great significance to improve the network robustness against cascading failure. Many previous existing works on load-redistribution strategies require global information, which is not suitable for large scale networks, and some strategies based on local information assume that the load of a node is always its initial load before the network is attacked, and the load of the failure node is redistributed to its neighbors according to their initial load or initial residual capacity. This paper proposes a new load-redistribution strategy based on local information considering an ever-changing load. It redistributes the loads of the failure node to its nearest neighbors according to their current residual capacity, which makes full use of the residual capacity of the network. Experiments are conducted on two typical networks and two real networks, and the experimental results show that the new load-redistribution strategy can reduce the size of cascading failure efficiently. (paper)

  12. Switched Control Strategies of Aggregated Commercial HVAC Systems for Demand Response in Smart Grids

    Directory of Open Access Journals (Sweden)

    Kai Ma

    2017-07-01

    Full Text Available This work proposes three switched control strategies for aggregated heating, ventilation, and air conditioning (HVAC systems in commercial buildings to track the automatic generation control (AGC signal in smart grid. The existing control strategies include the direct load control strategy and the setpoint regulation strategy. The direct load control strategy cannot track the AGC signal when the state of charge (SOC of the aggregated thermostatically controlled loads (TCLs exceeds their regulation capacity, while the setpoint regulation strategy provides flexible regulation capacity, but causes larger tracking errors. To improve the tracking performance, we took the advantages of the two control modes and developed three switched control strategies. The control strategies switch between the direct load control mode and the setpoint regulation mode according to different switching indices. Specifically, we design a discrete-time controller and optimize the controller parameter for the setpoint regulation strategy using the Fibonacci optimization algorithm, enabling us to propose two switched control strategies across multiple time steps. Furthermore, we extend the switched control strategies by introducing a two-stage regulation in a single time step. Simulation results demonstrate that the proposed switched control strategies can reduce the tracking errors for frequency regulation.

  13. A load-sharing control scheme for a microgrid with a fixed frequency inverter

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Zhihao; Huang, Xinhong; Jiang, Jin [Department of Electrical and Computer Engineering, The University of Western Ontario, 1151 Richmond St., London, Ontario (Canada); Wu, Bin [Department of Electrical and Computer Engineering, Ryerson University, Toronto, Ontario (Canada)

    2010-03-15

    In this paper, a load-sharing control strategy is developed for a microgrid consisting of a fuel cell power module and two synchronous generators in a stand-alone environment. The fuel cell is interfaced with the synchronous generators through a DC/AC inverter to convert unregulated DC to a three-phase AC. Since the frequency of the DC/AC inverter is fixed, the conventional load-frequency control scheme cannot be used for load-sharing control. To alleviate this problem, a load-voltage control scheme is developed. The theoretical analysis and experimental validation of the proposed scheme are presented. It is shown, by theoretical analysis and experiments, that this control strategy can effectively distribute the load among the different energy sources based on their individual pre-defined load-voltage droop characteristics. (author)

  14. Control and Protection Cooperation Strategy for Voltage Instability

    DEFF Research Database (Denmark)

    Liu, Zhou; Chen, Zhe; Sun, Haishun

    2012-01-01

    Most cascaded blackouts are caused by unexpected backup relay operations due to low voltage or overload state caused by post fault load restoration dynamics. If such state can be sensed and adjusted appropriately prior to those relay actions, system stability might be sustained. This paper proposed...... a control and protection cooperation strategy to prevent post fault voltage instability. The multi-agent technology is applied for the strategy implementation; the criteria based on wide area measured apparent impedances are defined to choose the control strategy, such as tap changer adjusting or load...

  15. On load flow control in electric power systems

    Energy Technology Data Exchange (ETDEWEB)

    Herbig, Arnim

    2000-01-01

    This dissertation deals with the control of active power flow, or load flow in electric power systems. During the last few years, interest in the possibilities to control the active power flows in transmission systems has increased significantly. There is a number of reasons for this, coming both from the application side - that is, from power system operations - and from the technological side. where advances in power electronics and related technologies have made new system components available. Load flow control is by nature a multi-input multi-output problem, since any change of load flow in one line will be complemented by changes in other lines. Strong cross-coupling between controllable components is to be expected, and the possibility of adverse interactions between these components cannot be rejected straightaway. Interactions with dynamic phenomena in the power system are also a source of concern. Three controllable components are investigated in this thesis, namely the controlled series capacitor (CSC), the phase angle regulator (PAR), and the unified power flow controller (UPFC). Properties and characteristics of these devices axe investigated and discussed. A simple control strategy is proposed. This strategy is then analyzed extensively. Mathematical methods and physical knowledge about the pertinent phenomena are combined, and it is shown that this control strategy can be used for a fairly general class of devices. Computer simulations of the controlled system provide insight into the system behavior in a system of reasonable size. The robustness and stability of the control system are discussed as are its limits. Further, the behavior of the control strategy in a system where the modeling allows for dynamic phenomena are investigated with computer simulations. It is discussed under which circumstances the control action has beneficial or detrimental effect on the system dynamics. Finally, a graphical approach for analyzing the effect of controllers

  16. Fuzzy Load-Shedding Strategy Considering Photovoltaic Output Fluctuation Characteristics and Static Voltage Stability

    Directory of Open Access Journals (Sweden)

    Sheng Li

    2018-03-01

    Full Text Available Based on the equilibrium point equations of a classic three-node system integrated with a large-scale photovoltaic cell (PV power plant, the impact of PV output fluctuation on the saddle-node bifurcation (SNB was derived and analyzed. When PV runs in a unity power factor and the PV output active power Ppv is not too large (several hundred MW and below, the PV output fluctuation has little effect on the SNB point position and load margin index, so that the load margin index can be calculated online using the SNB point at Ppv = 0 pu. On the other hand, the local reactive power compensation in the load center can effectively raise the load bus voltage and make the voltage stability problem become more concealed; the traditional under-voltage load-shedding (UVLS strategy only carries out load shedding when the bus voltage amplitude is below the specified value and cannot effectively maintain the system static voltage stability in some occasions. In this paper, a fuzzy load-shedding strategy considering the impact of PV output fluctuations for the large-scale PV grid-connected system was designed, taking the load bus voltage amplitude and load margin index as fuzzy input variables, and the load-shedding command as a fuzzy output variable. Nine fuzzy IF-THEN rules were extracted for the fuzzy controller and the corresponding practical calculation method of load-shedding quantity was put forward. The simulation results of the classic three-node system and IEEE 14-bus system, both with a 100 MW PV power plant, verified the effectiveness of the fuzzy load-shedding controller whose input variable load margin index was calculated using the SNB point when the PV active power output was 0. The designed fuzzy load-shedding strategy can compensate for the defect—that the traditional UVLS strategy cannot effectively guarantee the system static voltage stability—and it can be widely used in power grids integrated with PV power plants whose scales are at a

  17. Research on a Compound Control Strategy of Three-Phase Inverter for Unbalanced Loads

    Directory of Open Access Journals (Sweden)

    Yue Gaili

    2017-01-01

    Full Text Available To solve the problem of unbalanced output voltage of inverter under three-phase unbalanced load. In this paper, the main circuit topology using three-phase three-wire inverter topology. Established the mathematical model in several different coordinate system of the three-phase inverter. A compound control method is proposed by combining voltage current dual loop control method and repetitive control method, The control method is realized in three - phase 400 Hz inverter, and can meet the demand of unbalanced load to inverter, the reliability of the inverter circuit is improved. At the end of this paper, Matlab simulation analysis and experimental results are given, it is proved that the composite control method designed in this paper has a strong ability of unbalanced load.

  18. Advanced operational strategy for the IRIS reactor: Load follow through mechanical shim (MSHIM)

    International Nuclear Information System (INIS)

    Franceschini, Fausto; Petrovic, Bojan

    2008-01-01

    The renaissance of nuclear power brings more attention to advanced reactor designs and their improved performance and flexibility, including their enhanced load follow capability. Reactor control strategy used to perform transients including power changes has impact on the overall control system design. In particular, as the power change is performed within a load follow maneuver, several modifications occur in the core from a neutronic view point: the fuel and moderator temperature change, the xenon concentration and distribution are modified, the power distribution skewed axially, etc. These changes need to be adequately counterbalanced to keep both the core critical and the power distribution acceptable. The traditional approach in PWRs is to compensate for the reactivity change due to the power variation by adjusting the soluble boron concentration and moving a limited number of control rod banks. However, advanced reactors may adopt a different strategy for a variety of reasons. For example, water-cooled reactors that do not use soluble boron in coolant obviously cannot use its adjustment for this purpose. Moreover, Integral Primary System Reactors (IPSRs) using soluble boron, due to their integral design, have a large inventory of primary coolant. Therefore dilution/boration strategy, while in principle an option, becomes expensive for short time changes and leads to large volume of liquid effluent, in particular toward the end of cycle. Therefore, a capability to perform load follow without changing soluble boron concentration is very desirable for a range of reactor designs. International Reactor Innovative and Secure (IRIS) is an advanced medium-size IPSR that has been selected as the reference reactor for the purpose of this study. A capability to perform load follow maneuvers without changing soluble boron concentration has been examined and demonstrated through implementation of the Westinghouse Mechanical Shim (MSHIM) control strategy. A control bank

  19. Application of artificial intelligence in load frequency control of ...

    African Journals Online (AJOL)

    This paper presents the use of artificial intelligence to study the load frequency control of interconnected power system. In the proposed scheme, a control methodology is developed using Artificial Neural Network (ANN) and Fuzzy Logic controller (FLC) for interconnected hydro-thermal power system. The control strategies ...

  20. An improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions

    DEFF Research Database (Denmark)

    Naderipour, Amirreza; Asuhaimi Mohd Zin, Abdullah; Bin Habibuddin, Mohd Hafiz

    2017-01-01

    In recent years, renewable energy sources have been considered the most encouraging resources for grid and off-grid power generation. This paper presents an improved current control strategy for a three-phase photovoltaic grid-connected inverter (GCI) under unbalanced and nonlinear load conditions....... It is challenging to suppress the harmonic content in the output current below a pre-set value in the GCI. It is also difficult to compensate for unbalanced loads even when the grid is under disruption due to total harmonic distortion (THD) and unbalanced loads. The primary advantage and objective of this method...... is to effectively compensate for the harmonic current content of the grid current and microgrid without the use of any compensation devices, such as active and passive filters. This method leads to a very low THD in both the GCI currents and the current exchanged with the grid. The control approach is designed...

  1. Optimisation of load control

    International Nuclear Information System (INIS)

    Koponen, P.

    1998-01-01

    Electricity cannot be stored in large quantities. That is why the electricity supply and consumption are always almost equal in large power supply systems. If this balance were disturbed beyond stability, the system or a part of it would collapse until a new stable equilibrium is reached. The balance between supply and consumption is mainly maintained by controlling the power production, but also the electricity consumption or, in other words, the load is controlled. Controlling the load of the power supply system is important, if easily controllable power production capacity is limited. Temporary shortage of capacity causes high peaks in the energy price in the electricity market. Load control either reduces the electricity consumption during peak consumption and peak price or moves electricity consumption to some other time. The project Optimisation of Load Control is a part of the EDISON research program for distribution automation. The following areas were studied: Optimization of space heating and ventilation, when electricity price is time variable, load control model in power purchase optimization, optimization of direct load control sequences, interaction between load control optimization and power purchase optimization, literature on load control, optimization methods and field tests and response models of direct load control and the effects of the electricity market deregulation on load control. An overview of the main results is given in this chapter

  2. Optimisation of load control

    Energy Technology Data Exchange (ETDEWEB)

    Koponen, P [VTT Energy, Espoo (Finland)

    1998-08-01

    Electricity cannot be stored in large quantities. That is why the electricity supply and consumption are always almost equal in large power supply systems. If this balance were disturbed beyond stability, the system or a part of it would collapse until a new stable equilibrium is reached. The balance between supply and consumption is mainly maintained by controlling the power production, but also the electricity consumption or, in other words, the load is controlled. Controlling the load of the power supply system is important, if easily controllable power production capacity is limited. Temporary shortage of capacity causes high peaks in the energy price in the electricity market. Load control either reduces the electricity consumption during peak consumption and peak price or moves electricity consumption to some other time. The project Optimisation of Load Control is a part of the EDISON research program for distribution automation. The following areas were studied: Optimization of space heating and ventilation, when electricity price is time variable, load control model in power purchase optimization, optimization of direct load control sequences, interaction between load control optimization and power purchase optimization, literature on load control, optimization methods and field tests and response models of direct load control and the effects of the electricity market deregulation on load control. An overview of the main results is given in this chapter

  3. Controlling Buffeting Loads by Rudder and Piezo-Actuation

    Science.gov (United States)

    Moses, Robert W.; Pototzky, Anthony S.; Henderson, Douglas A.; Galea, Stephen C.; Manokaran, Donald S.; Zimcik, David G.; Wickramasinghe, Viresh; Pitt, Dale M.; Gamble, Michael A.

    2005-01-01

    High performance aircraft, especially those with twin vertical tails, encounter unsteady buffet loads when flying at high angles of attack. These stochastic loads result in significant stresses, which may cause fatigue damage leading to restricted capabilities and availability of the aircraft. An international collaborative research activity among Australia, Canada and the United States, conducted under the auspices of The Technical Cooperation Program (TTCP) contributed resources toward a program that coalesced a broad range of technical knowledge and expertise into a single investigation to demonstrate the enhanced performance and capability of the advanced active Buffet Load Alleviation ( ) control system in preparation for a flight test demonstration. The research team investigated the use of active structural control to alleviate the damaging structural response to these loads by applying advanced directional piezoelectric actuators, the aircraft rudder, switch mode amplifiers, and advanced control strategies on an F/A-18 aircraft empennage. Some results of the full-scale investigation are presented herein.

  4. Biogas-pH automation control strategy for optimizing organic loading rate of anaerobic membrane bioreactor treating high COD wastewater.

    Science.gov (United States)

    Yu, Dawei; Liu, Jibao; Sui, Qianwen; Wei, Yuansong

    2016-03-01

    Control of organic loading rate (OLR) is essential for anaerobic digestion treating high COD wastewater, which would cause operation failure by overload or less efficiency by underload. A novel biogas-pH automation control strategy using the combined gas-liquor phase monitoring was developed for an anaerobic membrane bioreactor (AnMBR) treating high COD (27.53 g·L(-1)) starch wastewater. The biogas-pH strategy was proceeded with threshold between biogas production rate >98 Nml·h(-1) preventing overload and pH>7.4 preventing underload, which were determined by methane production kinetics and pH titration of methanogenesis slurry, respectively. The OLR and the effluent COD were doubled as 11.81 kgCOD·kgVSS(-1)·d(-1) and halved as 253.4 mg·L(-1), respectively, comparing with a constant OLR control strategy. Meanwhile COD removal rate, biogas yield and methane concentration were synchronously improved to 99.1%, 312 Nml·gCODin(-1) and 74%, respectively. Using the biogas-pH strategy, AnMBR formed a "pH self-regulation ternary buffer system" which seizes carbon dioxide and hence provides sufficient buffering capacity. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. An improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions

    Science.gov (United States)

    Naderipour, Amirreza; Asuhaimi Mohd Zin, Abdullah; Bin Habibuddin, Mohd Hafiz; Miveh, Mohammad Reza; Guerrero, Josep M.

    2017-01-01

    In recent years, renewable energy sources have been considered the most encouraging resources for grid and off-grid power generation. This paper presents an improved current control strategy for a three-phase photovoltaic grid-connected inverter (GCI) under unbalanced and nonlinear load conditions. It is challenging to suppress the harmonic content in the output current below a pre-set value in the GCI. It is also difficult to compensate for unbalanced loads even when the grid is under disruption due to total harmonic distortion (THD) and unbalanced loads. The primary advantage and objective of this method is to effectively compensate for the harmonic current content of the grid current and microgrid without the use of any compensation devices, such as active and passive filters. This method leads to a very low THD in both the GCI currents and the current exchanged with the grid. The control approach is designed to control the active and reactive power and harmonic current compensation, and it also corrects the system unbalance. The proposed control method features the synchronous reference frame (SRF) method. Simulation results are presented to demonstrate the effective performance of the proposed method. PMID:28192436

  6. An improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions.

    Science.gov (United States)

    Naderipour, Amirreza; Asuhaimi Mohd Zin, Abdullah; Bin Habibuddin, Mohd Hafiz; Miveh, Mohammad Reza; Guerrero, Josep M

    2017-01-01

    In recent years, renewable energy sources have been considered the most encouraging resources for grid and off-grid power generation. This paper presents an improved current control strategy for a three-phase photovoltaic grid-connected inverter (GCI) under unbalanced and nonlinear load conditions. It is challenging to suppress the harmonic content in the output current below a pre-set value in the GCI. It is also difficult to compensate for unbalanced loads even when the grid is under disruption due to total harmonic distortion (THD) and unbalanced loads. The primary advantage and objective of this method is to effectively compensate for the harmonic current content of the grid current and microgrid without the use of any compensation devices, such as active and passive filters. This method leads to a very low THD in both the GCI currents and the current exchanged with the grid. The control approach is designed to control the active and reactive power and harmonic current compensation, and it also corrects the system unbalance. The proposed control method features the synchronous reference frame (SRF) method. Simulation results are presented to demonstrate the effective performance of the proposed method.

  7. Active load management in an intelligent building using model predictive control strategy

    DEFF Research Database (Denmark)

    Zong, Yi; Kullmann, Daniel; Thavlov, Anders

    2011-01-01

    This paper introduces PowerFlexHouse, a research facility for exploring the technical potential of active load management in a distributed power system (SYSLAB) with a high penetration of renewable energy and presents in detail on how to implement a thermal model predictive controller for load...... shifting in PowerFlexHouse heaters' power consumption scheme. With this demand side control study, it is expected that this method of demand response can dramatically raise energy efficiencies and improve grid reliability, when there is a high penetration of intermittent energy resources in the power...

  8. Modeling and distributed gain scheduling strategy for load frequency control in smart grids with communication topology changes.

    Science.gov (United States)

    Liu, Shichao; Liu, Xiaoping P; El Saddik, Abdulmotaleb

    2014-03-01

    In this paper, we investigate the modeling and distributed control problems for the load frequency control (LFC) in a smart grid. In contrast with existing works, we consider more practical and real scenarios, where the communication topology of the smart grid changes because of either link failures or packet losses. These topology changes are modeled as a time-varying communication topology matrix. By using this matrix, a new closed-loop power system model is proposed to integrate the communication topology changes into the dynamics of a physical power system. The globally asymptotical stability of this closed-loop power system is analyzed. A distributed gain scheduling LFC strategy is proposed to compensate for the potential degradation of dynamic performance (mean square errors of state vectors) of the power system under communication topology changes. In comparison to conventional centralized control approaches, the proposed method can improve the robustness of the smart grid to the variation of the communication network as well as to reduce computation load. Simulation results show that the proposed distributed gain scheduling approach is capable to improve the robustness of the smart grid to communication topology changes. © 2013 ISA. Published by ISA. All rights reserved.

  9. Application of MSHIM core control strategy for westinghouse AP1000 nuclear power plant

    International Nuclear Information System (INIS)

    Onoue, Masaaki; Kawanishi, Tomohiro; Carlson, William R.; Morita, Toshio

    2003-01-01

    Westinghouse has developed a new core control strategy, in which two independently moving Rod Cluster Control Assembly (RCCA) groups are utilized for core control; one group for reactivity/temperature control, the other for axial power distribution (Axial Offset) control. This control procedure eliminates the need for Chemical Shim adjustments during power maneuvers, such as load follow, and is designated MSHIM (Mechanical Shim). This core control strategy is utilized in the AP1000. In the AP1000, it is possible to perform MSHIM load follow maneuvers for up to 95% of cycle life without changing the soluble boron concentration in the moderator. This core control strategy has been evaluated, via computer simulations, to provide appropriate margins to core and fuel design limits during normal operation maneuvers (including load follow operations) and also during anticipated Condition II accident transients. The primary benefits of MSHIM as a control strategy are as follows; Power change operation can be totally automated due to the elimination of boron concentration adjustments. Full load follow capability is achievable for up to more than 95% of cycle life. Load follow operations performed solely by mechanical devices results in a significant reduction in the boron system requirements and a significant reduction in daily effluent to be processed. (author)

  10. A flexible control strategy of plug-in electric vehicles operating in seven modes for smoothing load power curves in smart grid

    International Nuclear Information System (INIS)

    Khemakhem, Siwar; Rekik, Mouna; Krichen, Lotfi

    2017-01-01

    Plug-in electric vehicles (PEVs) seem to be an interesting new electrical load for improving the reliability of smart grid. The purpose of this work is to investigate a supervision strategy based on regulated charging of PEVs in order to guarantee an optimized power management of the system and consequently a flatter power demand curve. The system mainly includes PEVs powered by a Lithium-ion battery ensuring the charging and discharging operations of these PEVs at home and a daily load power demanded by home appliances. The purpose of the considered strategy is to detect the connection status of each PEV and to establish the priority order between these PEVs with certain flexibility which results in managing the PEVs through seven operating modes. The response of the control algorithm enables to ensure the power flow exchange between the PEVs and the electrical grid, especially at rush hours, and to minimize load power variance aiming to achieve the smoothness for the power demand curve and to reduce the stress of the electrical grid. The simulation results are presented in order to illustrate the efficiency of this power control approach. - Highlights: • A flexible power management algorithm of Plug-in electric vehicle is proposed. • This control can be applied for any home equipped with two PEVs. • The response is to ensure the power flow exchange between PEVs and power grid. • The main contribution is to achieve the smoothness for the daily power demand curve.

  11. Load management: Model-based control of aggregate power for populations of thermostatically controlled loads

    International Nuclear Information System (INIS)

    Perfumo, Cristian; Kofman, Ernesto; Braslavsky, Julio H.; Ward, John K.

    2012-01-01

    Highlights: ► Characterisation of power response of a population of air conditioners. ► Implementation of demand side management on a group of air conditioners. ► Design of a controller for the power output of a group of air conditioners. ► Quantification of comfort impact of demand side management. - Abstract: Large groups of electrical loads can be controlled as a single entity to reduce their aggregate power demand in the electricity network. This approach, known as load management (LM) or demand response, offers an alternative to the traditional paradigm in the electricity market, where matching supply and demand is achieved solely by regulating how much generation is dispatched. Thermostatically controlled loads (TCLs), such as air conditioners (ACs) and fridges, are particularly suitable for LM, which can be implemented using feedback control techniques to regulate their aggregate power. To achieve high performance, such feedback control techniques require an accurate mathematical model of the TCL aggregate dynamics. Although such models have been developed, they appear too complex to be effectively used in control design. In this paper we develop a mathematical model aimed at the design of a model-based feedback control strategy. The proposed model analytically characterises the aggregate power response of a population of ACs to a simultaneous step change in temperature set points. Based on this model, we then derive, and completely parametrise in terms of the ACs ensemble properties, a reduced-order mathematical model to design an internal-model controller that regulates aggregate power by broadcasting temperature set-point offset changes. The proposed controller achieves high LM performance provided the ACs are equipped with high resolution thermostats. With coarser resolution thermostats, which are typical in present commercial and residential ACs, performance deteriorates significantly. This limitation is overcome by subdividing the population

  12. Multi-stage fuzzy load frequency control using PSO

    International Nuclear Information System (INIS)

    Shayeghi, H.; Jalili, A.; Shayanfar, H.A.

    2008-01-01

    In this paper, a particle swarm optimization (PSO) based multi-stage fuzzy (PSOMSF) controller is proposed for solution of the load frequency control (LFC) problem in a restructured power system that operate under deregulation based on the bilateral policy scheme. In this strategy the control is tuned on line from the knowledge base and fuzzy inference, which request fewer sources and has two rule base sets. In the proposed method, for achieving the desired level of robust performance, exact tuning of membership functions is very important. Thus, to reduce the design effort and find a better fuzzy system control, membership functions are designed automatically by PSO algorithm, that has a strong ability to find the most optimistic results. The motivation for using the PSO technique is to reduce fuzzy system effort and take large parametric uncertainties into account. This newly developed control strategy combines the advantage of PSO and fuzzy system control techniques and leads to a flexible controller with simple stricture that is easy to implement. The proposed PSO based MSF (PSOMSF) controller is tested on a three-area restructured power system under different operating conditions and contract variations. The results of the proposed PSOMSF controller are compared with genetic algorithm based multi-stage fuzzy (GAMSF) control through some performance indices to illustrate its robust performance for a wide range of system parameters and load changes

  13. Multi-stage fuzzy load frequency control using PSO

    Energy Technology Data Exchange (ETDEWEB)

    Shayeghi, H. [Technical Engineering Department, University of Mohaghegh Ardabili, Ardabil (Iran); Jalili, A. [Islamic Azad University, Ardabil Branch, Ardabil (Iran); Shayanfar, H.A. [Center of Excellence for Power Automation and Operation, Electrical Engineering Department, Iran University of Science and Technology, Tehran (Iran)

    2008-10-15

    In this paper, a particle swarm optimization (PSO) based multi-stage fuzzy (PSOMSF) controller is proposed for solution of the load frequency control (LFC) problem in a restructured power system that operate under deregulation based on the bilateral policy scheme. In this strategy the control is tuned on line from the knowledge base and fuzzy inference, which request fewer sources and has two rule base sets. In the proposed method, for achieving the desired level of robust performance, exact tuning of membership functions is very important. Thus, to reduce the design effort and find a better fuzzy system control, membership functions are designed automatically by PSO algorithm, that has a strong ability to find the most optimistic results. The motivation for using the PSO technique is to reduce fuzzy system effort and take large parametric uncertainties into account. This newly developed control strategy combines the advantage of PSO and fuzzy system control techniques and leads to a flexible controller with simple stricture that is easy to implement. The proposed PSO based MSF (PSOMSF) controller is tested on a three-area restructured power system under different operating conditions and contract variations. The results of the proposed PSOMSF controller are compared with genetic algorithm based multi-stage fuzzy (GAMSF) control through some performance indices to illustrate its robust performance for a wide range of system parameters and load changes. (author)

  14. Variable Parameter Nonlinear Control for Maximum Power Point Tracking Considering Mitigation of Drive-train Load

    Institute of Scientific and Technical Information of China (English)

    Zaiyu; Chen; Minghui; Yin; Lianjun; Zhou; Yaping; Xia; Jiankun; Liu; Yun; Zou

    2017-01-01

    Since mechanical loads exert a significant influence on the life span of wind turbines, the reduction of transient load on drive-train shaft has received more attention when implementing a maximum power point tracking(MPPT) controller.Moreover, a trade-off between the efficiency of wind energy extraction and the load level of drive-train shaft becomes a key issue. However, for the existing control strategies based on nonlinear model of wind turbines, the MPPT efficiencies are improved at the cost of the intensive fluctuation of generator torque and significant increase of transient load on drive train shaft. Hence, in this paper, a nonlinear controller with variable parameter is proposed for improving MPPT efficiency and mitigating transient load on drive-train simultaneously. Then,simulations on FAST(Fatigue, Aerodynamics, Structures, and Turbulence) code and experiments on the wind turbine simulator(WTS) based test bench are presented to verify the efficiency improvement of the proposed control strategy with less cost of drive-train load.

  15. Variable Parameter Nonlinear Control for Maximum Power Point Tracking Considering Mitigation of Drive-train Load

    Institute of Scientific and Technical Information of China (English)

    Zaiyu Chen; Minghui Yin; Lianjun Zhou; Yaping Xia; Jiankun Liu; Yun Zou

    2017-01-01

    Since mechanical loads exert a significant influence on the life span of wind turbines,the reduction of transient load on drive-train shaft has received more attention when implementing a maximum power point tracking (MPPT) controller.Moreover,a trade-off between the efficiency of wind energy extraction and the load level of drive-train shaft becomes a key issue.However,for the existing control strategies based on nonlinear model of wind turbines,the MPPT efficiencies are improved at the cost of the intensive fluctuation of generator torque and significant increase of transient load on drive train shaft.Hence,in this paper,a nonlinear controller with variable parameter is proposed for improving MPPT efficiency and mitigating transient load on drive-train simultaneously.Then,simulations on FAST (Fatigue,Aerodynamics,Structures,and Turbulence) code and experiments on the wind turbine simulator (WTS) based test bench are presented to verify the efficiency improvement of the proposed control strategy with less cost of drive-train load.

  16. Wind farm models and control strategies

    Energy Technology Data Exchange (ETDEWEB)

    Soerensen, Poul; Hansen, Anca D.; Iov, F.; Blaabjerg, F.; Donovan, M.H.

    2005-08-01

    This report describes models and control strategies for 3 different concepts of wind farms. Initially, the potential in improvement of grid integration, structural loads and energy production is investigated in a survey of opportunities. Then simulation models are described, including wind turbine models for a fixed speed wind turbine with active stall control and a variable speed wind turbine with doubly-fed induction generator. After that, the 3 wind farm concepts and control strategies are described. The 3 concepts are AC connected doubly fed turbines, AC connected active stall turbines and DC connected active stall turbines. Finally, some simulation examples and conclusions are presented. (au)

  17. Utilization of Model Predictive Control to Balance Power Absorption Against Load Accumulation

    Energy Technology Data Exchange (ETDEWEB)

    Abbas, Nikhar [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Tom, Nathan M [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-06-03

    Wave energy converter (WEC) control strategies have been primarily focused on maximizing power absorption. The use of model predictive control strategies allows for a finite-horizon, multiterm objective function to be solved. This work utilizes a multiterm objective function to maximize power absorption while minimizing the structural loads on the WEC system. Furthermore, a Kalman filter and autoregressive model were used to estimate and forecast the wave exciting force and predict the future dynamics of the WEC. The WEC's power-take-off time-averaged power and structural loads under a perfect forecast assumption in irregular waves were compared against results obtained from the Kalman filter and autoregressive model to evaluate model predictive control performance.

  18. Risk Assessment of Heating, Ventilating, and Air-Conditioning Strategies in Low-Load Homes

    Energy Technology Data Exchange (ETDEWEB)

    Poerschke, Andrew [IBACOS, Inc., Pittsburgh, PA (United States)

    2016-02-17

    "Modern, energy efficient homes conforming to the Zero Energy Ready Home standard face the challenge of meeting high customer expectations for comfort. Traditional heating, ventilation, and air conditioning (HVAC) sizing and control strategies may be insufficient to adequately condition each zone due to unique load patterns in each room caused by a number of factors. These factors include solar heat gains, occupant-related gains, and gains associated with appliances and electronics. Because of shrinking shell loads, these intermittent factors are having an increasingly significant impact on the thermal load in each zone. Consequently, occupant comfort can be compromised. To evaluate the impact of climate and house geometry, as well as HVAC system and control strategies on comfort conditions, IBACOS analyzed the results of 99 TRNSYS multiple-zone simulations. The results of this analysis indicate that for simple-geometry and single-story plans, a single zone and thermostat can adequately condition the entire house. Demanding house geometry and houses with multiple stories require the consideration of multiple thermostats and multiple zones.

  19. Grid-forming VSC control in four-wire systems with unbalanced nonlinear loads

    DEFF Research Database (Denmark)

    Lliuyacca, Ruben; Mauricioa, Juan M.; Gomez-Exposito, Antonio

    2017-01-01

    A grid-forming voltage source converter (VSC) is responsible to hold voltage and frequency in autonomous operation of isolated systems. In the presence of unbalanced loads, a fourth leg is added to provide current path for neutral currents. In this paper, a novel control scheme for a four-leg VSC...... feeding unbalanced linear and nonlinear loads is proposed. The control is based on two control blocks. A main control commands the switching sequence to the three-phase VSC ensuring balanced three-phase voltage at the output; and an independent control to the fourth leg drives neutral currents that might...... response during system disturbances and mitigation of harmonics when nonlinear loads are present. Simulations and experimental results are presented to verify the performance of the proposed control strategy....

  20. Relevance of aerodynamic modelling for load reduction control strategies of two-bladed wind turbines

    Science.gov (United States)

    Luhmann, B.; Cheng, P. W.

    2014-06-01

    A new load reduction concept is being developed for the two-bladed prototype of the Skywind 3.5MW wind turbine. Due to transport and installation advantages both offshore and in complex terrain two-bladed turbine designs are potentially more cost-effective than comparable three-bladed configurations. A disadvantage of two-bladed wind turbines is the increased fatigue loading, which is a result of asymmetrically distributed rotor forces. The innovative load reduction concept of the Skywind prototype consists of a combination of cyclic pitch control and tumbling rotor kinematics to mitigate periodic structural loading. Aerodynamic design tools must be able to model correctly the advanced dynamics of the rotor. In this paper the impact of the aerodynamic modelling approach is investigated for critical operational modes of a two-bladed wind turbine. Using a lifting line free wake vortex code (FVM) the physical limitations of the classical blade element momentum theory (BEM) can be evaluated. During regular operation vertical shear and yawed inflow are the main contributors to periodic blade load asymmetry. It is shown that the near wake interaction of the blades under such conditions is not fully captured by the correction models of BEM approach. The differing prediction of local induction causes a high fatigue load uncertainty especially for two-bladed turbines. The implementation of both cyclic pitch control and a tumbling rotor can mitigate the fatigue loading by increasing the aerodynamic and structural damping. The influence of the time and space variant vorticity distribution in the near wake is evaluated in detail for different cyclic pitch control functions and tumble dynamics respectively. It is demonstrated that dynamic inflow as well as wake blade interaction have a significant impact on the calculated blade forces and need to be accounted for by the aerodynamic modelling approach. Aeroelastic simulations are carried out using the high fidelity multi body

  1. A Study on Load Following Operation Strategy to Minimize Boric-acid Adjustment

    International Nuclear Information System (INIS)

    Yoo, Jae Woon

    1997-02-01

    Applicability of the MSHIM control strategy, which has been developed by Westinghouse and characterized by elimination of the adjustment to the boron concentration during load maneuvering, to 1300MWe KNGR Cycle-1 is examined by simulation based on one-dimensional transient analyses code, ONED94, under the conditions of relatively large xenon worth and high amplitude of xenon oscillation. CASMO-3/MASTER code system is used to generate the ONED94 model. A processing code, which is referred to as MAS2ONED, is also developed to transform the MASTER calculation results to ONED94 cross section library. The three types of power maneuvering, daily maneuvering, extended weekend load follow, and spinning reserve capacity are simulated to evaluate the capability of the selected load follow technology, by using ONED94 code. By showing that the calculated total peaking factor is maintained below safety limit, it is proved that load follow operation without boron adjustment is feasible with simple control rod motion only. It is expected that the results of this study, such as control rod parameters could give a contribution to the development of load following technology in our country. The developed process code could be utilized in the another simulation of power maneuver in the future

  2. Utilization of Model Predictive Control to Balance Power Absorption Against Load Accumulation: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Abbas, Nikhar; Tom, Nathan

    2017-09-01

    Wave energy converter (WEC) control strategies have been primarily focused on maximizing power absorption. The use of model predictive control strategies allows for a finite-horizon, multiterm objective function to be solved. This work utilizes a multiterm objective function to maximize power absorption while minimizing the structural loads on the WEC system. Furthermore, a Kalman filter and autoregressive model were used to estimate and forecast the wave exciting force and predict the future dynamics of the WEC. The WEC's power-take-off time-averaged power and structural loads under a perfect forecast assumption in irregular waves were compared against results obtained from the Kalman filter and autoregressive model to evaluate model predictive control performance.

  3. Investigation on energy storage and quick load change control of subcritical circulating fluidized bed boiler units

    International Nuclear Information System (INIS)

    Gao, Mingming; Hong, Feng; Liu, Jizhen

    2017-01-01

    Highlights: • The model of energy storage of subcritical CFB boilers is established. • The capacity and increment rate of heat storage are quantified. • A novel load control strategy is proposed to improve the quick load change ability. • An application on the 300 MW CFB unit proves the load change rate to 5–8 MW/min. - Abstract: The energy storage of circulating fluidized bed (CFB) boilers on fuel side cannot be ignored due to the special combustion type different from pulverized coal boilers. The sizable energy storage makes it possible for CFB units to enhance the quick load change ability and to increase the scale of new energy power connected into grid. Through mechanism analysis, the model of energy storage of subcritical CFB boilers has been established for the first time. Then by the project practice, the quantitative analysis is demonstrated for the capacity and control characteristics of energy storage on fuel side and steam water side. Based on the control characteristics and the transformation of the energy storage, a coordinated control system (CCS) control strategy named advanced energy balance (AEB) is designed to shorten the response time through the use of energy storage and to accelerate the load change speed of subcritical CFB units. Finally, a case study on a 300 MW CFB unit proves the feasibility of the proposed control strategy.

  4. Multi-objective Extremum Seeking Control for Enhancement of Wind Turbine Power Capture with Load Reduction

    Science.gov (United States)

    Xiao, Yan; Li, Yaoyu; Rotea, Mario A.

    2016-09-01

    The primary objective in below rated wind speed (Region 2) is to maximize the turbine's energy capture. Due to uncertainty, variability of turbine characteristics and lack of inexpensive but precise wind measurements, model-free control strategies that do not use wind measurements such as Extremum Seeking Control (ESC) have received significant attention. Based on a dither-demodulation scheme, ESC can maximize the wind power capture in real time despite uncertainty, variabilities and lack of accurate wind measurements. The existing work on ESC based wind turbine control focuses on power capture only. In this paper, a multi-objective extremum seeking control strategy is proposed to achieve nearly optimum wind energy capture while decreasing structural fatigue loads. The performance index of the ESC combines the rotor power and penalty terms of the standard deviations of selected fatigue load variables. Simulation studies of the proposed multi-objective ESC demonstrate that the damage-equivalent loads of tower and/or blade loads can be reduced with slight compromise in energy capture.

  5. A sensitivity analysis approach to control of manipulators with unknown load

    International Nuclear Information System (INIS)

    Tzes, A.; Yurkovich, S.

    1987-01-01

    This paper presents a straightforward control strategy applied to an N-link manipulator holding an unknown load and driving its end effector along a prespecified trajectory. The control is constituted into two primary components. The non-adaptive component is derived from the inverse problem technique while the adaptive component is computed via the application of sensitivity analysis applied to the complete, centralized dynamic model of the manipulator. The result is a robust adaptive controller which tunes its parameters at specified time instants and can withstand all expected variations of the payload. The control synthesis is illustrated by simulations in a 2-link planar manipulator holding an unknown load

  6. Best control strategy for unified power quality conditioner (UPQC) based on simulation

    Energy Technology Data Exchange (ETDEWEB)

    Shayanfar, H.A. [Iran Univ. of Science and Technology, Tehran (Iran, Islamic Republic of). Dept. of Electrical Engineering; Tabatabaei, N.M. [Azarbaijan Univ. of Tarbiat Moallem, Tabriz (Iran, Islamic Republic of). Dept. of Electrical Engineering; Mokhtarpour, A. [Islamic Azad Univ., Tabriz (Iran, Islamic Republic of). Dept. of Electrical Engineering

    2007-07-01

    Electronic devices used in both industry and residences need high-quality energy to work properly. Unified Power Quality Conditioners (UPQC) solve any power quality problems faced by these devices. Three new control strategies for UPQCs were presented and their operation was investigated and compared using the MATLAB Simulink simulation software package. A UPQC consists of a Shunt-Active Filter and a Series Active Filter with a common direct current link to compensate for any source currents and delivered voltage to the load. As such, it isolates the utility from current quality problems associated with load. It also isolates the load from the voltage quality problems of the utility. In the first control strategy, the Parallel Active Filter (PAF) and Series Active Filter (SAF) are based on the Fourier transform theory. In the second control strategy, the Parallel Active Filter is based on the power quality theory and the Series Active Filter is based on the Fourier transform theory. In the third control strategy, the Parallel Active Filter is based on Fourier transform theory and the Series Active Filter is based on positive sequence detection. Operating the PAF using these methods compensates for reactive power and current harmonics, while operating the SAF compensates for imbalances, voltage harmonics and positive and zero sequences of utility voltages. MATLAB simulation software was used to explain the compensation resolution and speed of the 3 new control strategies. According to simulation test results, it was concluded that the best compensation speed and resolution can be obtained using the third control strategy. 7 refs., 2 tabs., 24 figs.

  7. Optimal Control and Operation Strategy for Wind Turbines Contributing to Grid Primary Frequency Regulation

    Directory of Open Access Journals (Sweden)

    Mun-Kyeom Kim

    2017-09-01

    Full Text Available This study introduces a frequency regulation strategy to enable the participation of wind turbines with permanent magnet synchronous generators (PMSGs. The optimal strategy focuses on developing the frequency support capability of PMSGs connected to the power system. Active power control is performed using maximum power point tracking (MPPT and de-loaded control to supply the required power reserve following a disturbance. A kinetic energy (KE reserve control is developed to enhance the frequency regulation capability of wind turbines. The coordination with the de-loaded control prevents instability in the PMSG wind system due to excessive KE discharge. A KE optimization method that maximizes the sum of the KE reserves at wind farms is also adopted to determine the de-loaded power reference for each PMSG wind turbine using the particle swarm optimization (PSO algorithm. To validate the effectiveness of the proposed optimal control and operation strategy, three different case studies are conducted using the PSCAD/EMTDC simulation tool. The results demonstrate that the optimal strategy enhances the frequency support contribution from PMSG wind turbines.

  8. Fatigue Load Modeling and Control for Wind Turbines based on Hysteresis Operators

    DEFF Research Database (Denmark)

    Barradas Berglind, Jose de Jesus; Wisniewski, Rafal; Soltani, Mohsen

    2015-01-01

    method based on hysteresis operators, which can be used in control loops. Furthermore, we propose a model predictive control (MPC) strategy that incorporates the online fatigue estimation through the objective function, where the ultimate goal in mind is to reduce the fatigue load of the wind turbine......The focus of this work is on fatigue load modeling and controller design for the wind turbine level. The main purpose is to include a model of the damage effects caused by the fatigue of the wind turbine components in the controller design process. This paper addresses an online fatigue estimation...

  9. Design and selection of load control strategies using a multiple objective model and evolutionary algorithms

    International Nuclear Information System (INIS)

    Gomes, Alvaro; Antunes, Carlos Henggeler; Martins, Antonio Gomes

    2005-01-01

    This paper aims at presenting a multiple objective model to evaluate the attractiveness of the use of demand resources (through load management control actions) by different stakeholders and in diverse structure scenarios in electricity systems. For the sake of model flexibility, the multiple (and conflicting) objective functions of technical, economical and quality of service nature are able to capture distinct market scenarios and operating entities that may be interested in promoting load management activities. The computation of compromise solutions is made by resorting to evolutionary algorithms, which are well suited to tackle multiobjective problems of combinatorial nature herein involving the identification and selection of control actions to be applied to groups of loads. (Author)

  10. Benchmarking of Control Strategies for Wastewater Treatment Plants

    DEFF Research Database (Denmark)

    Wastewater treatment plants are large non-linear systems subject to large perturbations in wastewater flow rate, load and composition. Nevertheless these plants have to be operated continuously, meeting stricter and stricter regulations. Many control strategies have been proposed in the literature...

  11. Different Predictive Control Strategies for Active Load Management in Distributed Power Systems with High Penetration of Renewable Energy Sources

    DEFF Research Database (Denmark)

    Zong, Yi; Bindner, Henrik W.; Gehrke, Oliver

    2013-01-01

    In order to achieve a Danish energy supply based on 100% renewable energy from combinations of wind, biomass, wave and solar power in 2050 and to cover 50% of the Danish electricity consumption by wind power in 2020, it requires more renewable energy in buildings and industries (e.g. cold stores......, greenhouses, etc.), and to coordinate the management of large numbers of distributed energy resources with the smart grid solution. This paper presents different predictive control (Genetic Algorithm-based and Model Predictive Control-based) strategies that schedule controlled loads in the industrial...... and residential sectors, based on dynamic power price and weather forecast, considering users’ comfort settings to meet an optimization objective, such as maximum profit or minimum energy consumption. Some field tests were carried out on a facility for intelligent, active and distributed power systems, which...

  12. A control strategy for multi-functional converter to improve grid power quality

    DEFF Research Database (Denmark)

    Li, Fei; Wang, Xiongfei; Chen, Zhe

    2011-01-01

    The extensive use of converter-interfacing distributed energy resources (DER), combined with a large amount of nonlinear and unbalanced loads connected to the distribution power system, has led to power quality problem. This paper proposes a control strategy for a three-phase four-leg multi-funct......) for multi-functional converter is described. Simulation and hardware in the loop real time test results carried on a three-phase four-wire distributed generation system illustrate the effectiveness of the proposed control strategy.......The extensive use of converter-interfacing distributed energy resources (DER), combined with a large amount of nonlinear and unbalanced loads connected to the distribution power system, has led to power quality problem. This paper proposes a control strategy for a three-phase four-leg multi......-functional converter which can compensate reactive power, harmonic currents, unbalance, and neutral current simultaneously under distorted voltage conditions, besides the active power exchange. The capacity of the converter is taken into account. The proposed control strategy based on synchronous reference frame (SRF...

  13. Optimum residential load management strategy for real time pricing (RTP) demand response programs

    International Nuclear Information System (INIS)

    Lujano-Rojas, Juan M.; Monteiro, Cláudio; Dufo-López, Rodolfo; Bernal-Agustín, José L.

    2012-01-01

    This paper presents an optimal load management strategy for residential consumers that utilizes the communication infrastructure of the future smart grid. The strategy considers predictions of electricity prices, energy demand, renewable power production, and power-purchase of energy of the consumer in determining the optimal relationship between hourly electricity prices and the use of different household appliances and electric vehicles in a typical smart house. The proposed strategy is illustrated using two study cases corresponding to a house located in Zaragoza (Spain) for a typical day in summer. Results show that the proposed model allows users to control their diary energy consumption and adapt their electricity bills to their actual economical situation. - Highlights: ► This work shows an optimal load management strategy for residential consumers. ► It has been considered the communication infrastructure of the future smart grid. ► A study case shows the optimal utilization of some appliances and electric vehicles. ► Results showed that the proposed model allows users to reduce their electricity bill.

  14. Forecasting Strategies for Predicting Peak Electric Load Days

    Science.gov (United States)

    Saxena, Harshit

    Academic institutions spend thousands of dollars every month on their electric power consumption. Some of these institutions follow a demand charges pricing structure; here the amount a customer pays to the utility is decided based on the total energy consumed during the month, with an additional charge based on the highest average power load required by the customer over a moving window of time as decided by the utility. Therefore, it is crucial for these institutions to minimize the time periods where a high amount of electric load is demanded over a short duration of time. In order to reduce the peak loads and have more uniform energy consumption, it is imperative to predict when these peaks occur, so that appropriate mitigation strategies can be developed. The research work presented in this thesis has been conducted for Rochester Institute of Technology (RIT), where the demand charges are decided based on a 15 minute sliding window panned over the entire month. This case study makes use of different statistical and machine learning algorithms to develop a forecasting strategy for predicting the peak electric load days of the month. The proposed strategy was tested for a whole year starting May 2015 to April 2016 during which a total of 57 peak days were observed. The model predicted a total of 74 peak days during this period, 40 of these cases were true positives, hence achieving an accuracy level of 70 percent. The results obtained with the proposed forecasting strategy are promising and demonstrate an annual savings potential worth about $80,000 for a single submeter of RIT.

  15. The LG-bank control concept: An improved method for PWR load-following operation

    International Nuclear Information System (INIS)

    Park, Won Seok; Christenson, J.M.

    1990-01-01

    In this paper the authors present the results of an investigation of a new pressurized water reactor load-following control concept that utilizes light gray (LG) banks in combination with a single high-worth bank. The investigation determined a control strategy and a set of nuclear design parameters for the control banks that permits unrestricted load-following operation over a wide power range at both beginning-of-cycle and end-of-cycle conditions. Advantages of the LG-bank control concept are that flexible load-following maneuvers can be performed without either making changes in the boron concentration or requiring the continuous insertion of a high-worth control bank. These features remove both of the disadvantages of current gray-bank load-following designs, which generally require the continuous insertion of a high-worth bank and in some cases also involve changes in the boron concentration

  16. Load Dependency of Postural Control--Kinematic and Neuromuscular Changes in Response to over and under Load Conditions.

    Science.gov (United States)

    Ritzmann, Ramona; Freyler, Kathrin; Weltin, Elmar; Krause, Anne; Gollhofer, Albert

    2015-01-01

    Load variation is associated with changes in joint torque and compensatory reflex activation and thus, has a considerable impact on balance control. Previous studies dealing with over (OL) and under loading (UL) used water buoyancy or additional weight with the side effects of increased friction and inertia, resulting in substantially modified test paradigms. The purpose of this study was to identify gravity-induced load dependency of postural control in comparable experimental conditions and to determine the underlying neuromuscular mechanisms. Balance performance was recorded under normal loading (NL, 1 g), UL (0.16 g 0.38 g) and OL (1.8 g) in monopedal stance. Center of pressure (COP) displacement and frequency distribution (low 0.15-0.5 Hz (LF), medium 0.5-2 Hz (MF), high 2-6 Hz (HF)) as well as ankle, knee and hip joint kinematics were assessed. Soleus spinal excitability was determined by H/M-recruitment curves (H/M-ratios). Compared to NL, OL caused an increase in ankle joint excursion, COP HF domain and H/M-ratio. Concomitantly, hip joint excursion and COP LF decreased. Compared to NL, UL caused modulations in the opposite direction: UL decreased ankle joint excursions, COP HF and H/M-ratio. Collaterally, hip joint excursion and COP LF increased. COP was augmented both in UL and in OL compared to NL. Subjects achieved postural stability in OL and UL with greater difficulty compared to NL. Reduced postural control was accompanied by modified balance strategies and compensatory reflex activation. With increasing load, a shift from hip to ankle strategy was observed. Accompanying, COP frequency distribution shifted from LF to HF and spinal excitability was enhanced. It is suggested that in OL, augmented ankle joint torques are compensated by quick reflex-induced postural reactions in distal muscles. Contrarily, UL is associated with diminished joint torques and thus, postural equilibrium may be controlled by the proximal segments to adjust the center of

  17. Load Dependency of Postural Control - Kinematic and Neuromuscular Changes in Response to over and under Load Conditions

    Science.gov (United States)

    Ritzmann, Ramona; Freyler, Kathrin; Weltin, Elmar; Krause, Anne; Gollhofer, Albert

    2015-01-01

    Introduction Load variation is associated with changes in joint torque and compensatory reflex activation and thus, has a considerable impact on balance control. Previous studies dealing with over (OL) and under loading (UL) used water buoyancy or additional weight with the side effects of increased friction and inertia, resulting in substantially modified test paradigms. The purpose of this study was to identify gravity-induced load dependency of postural control in comparable experimental conditions and to determine the underlying neuromuscular mechanisms. Methods Balance performance was recorded under normal loading (NL, 1g), UL (0.16g; 0.38g) and OL (1.8g) in monopedal stance. Center of pressure (COP) displacement and frequency distribution (low 0.15-0.5Hz (LF), medium 0.5-2Hz (MF), high 2-6Hz (HF)) as well as ankle, knee and hip joint kinematics were assessed. Soleus spinal excitability was determined by H/M-recruitment curves (H/M-ratios). Results Compared to NL, OL caused an increase in ankle joint excursion, COP HF domain and H/M-ratio. Concomitantly, hip joint excursion and COP LF decreased. Compared to NL, UL caused modulations in the opposite direction: UL decreased ankle joint excursions, COP HF and H/M-ratio. Collaterally, hip joint excursion and COP LF increased. COP was augmented both in UL and in OL compared to NL. Conclusion Subjects achieved postural stability in OL and UL with greater difficulty compared to NL. Reduced postural control was accompanied by modified balance strategies and compensatory reflex activation. With increasing load, a shift from hip to ankle strategy was observed. Accompanying, COP frequency distribution shifted from LF to HF and spinal excitability was enhanced. It is suggested that in OL, augmented ankle joint torques are compensated by quick reflex-induced postural reactions in distal muscles. Contrarily, UL is associated with diminished joint torques and thus, postural equilibrium may be controlled by the proximal

  18. Load Dependency of Postural Control--Kinematic and Neuromuscular Changes in Response to over and under Load Conditions.

    Directory of Open Access Journals (Sweden)

    Ramona Ritzmann

    Full Text Available Load variation is associated with changes in joint torque and compensatory reflex activation and thus, has a considerable impact on balance control. Previous studies dealing with over (OL and under loading (UL used water buoyancy or additional weight with the side effects of increased friction and inertia, resulting in substantially modified test paradigms. The purpose of this study was to identify gravity-induced load dependency of postural control in comparable experimental conditions and to determine the underlying neuromuscular mechanisms.Balance performance was recorded under normal loading (NL, 1 g, UL (0.16 g 0.38 g and OL (1.8 g in monopedal stance. Center of pressure (COP displacement and frequency distribution (low 0.15-0.5 Hz (LF, medium 0.5-2 Hz (MF, high 2-6 Hz (HF as well as ankle, knee and hip joint kinematics were assessed. Soleus spinal excitability was determined by H/M-recruitment curves (H/M-ratios.Compared to NL, OL caused an increase in ankle joint excursion, COP HF domain and H/M-ratio. Concomitantly, hip joint excursion and COP LF decreased. Compared to NL, UL caused modulations in the opposite direction: UL decreased ankle joint excursions, COP HF and H/M-ratio. Collaterally, hip joint excursion and COP LF increased. COP was augmented both in UL and in OL compared to NL.Subjects achieved postural stability in OL and UL with greater difficulty compared to NL. Reduced postural control was accompanied by modified balance strategies and compensatory reflex activation. With increasing load, a shift from hip to ankle strategy was observed. Accompanying, COP frequency distribution shifted from LF to HF and spinal excitability was enhanced. It is suggested that in OL, augmented ankle joint torques are compensated by quick reflex-induced postural reactions in distal muscles. Contrarily, UL is associated with diminished joint torques and thus, postural equilibrium may be controlled by the proximal segments to adjust the center of

  19. Load control strategies in 2G mobile network for W-CDMA radio ...

    African Journals Online (AJOL)

    Network planning requires a faithful analysis of each individual cell's capacity. In this paper, we examine load control equations as a resource allocation tool to analyse cell capacity for the uplink and downlink of Wideband Code Division Multiple Access (W-CDMA) networks. In the uplink, the noise rise is a parameter of ...

  20. Adaptive Control for Buck Power Converter Using Fixed Point Inducting Control and Zero Average Dynamics Strategies

    Science.gov (United States)

    Hoyos Velasco, Fredy Edimer; García, Nicolás Toro; Garcés Gómez, Yeison Alberto

    In this paper, the output voltage of a buck power converter is controlled by means of a quasi-sliding scheme. The Fixed Point Inducting Control (FPIC) technique is used for the control design, based on the Zero Average Dynamics (ZAD) strategy, including load estimation by means of the Least Mean Squares (LMS) method. The control scheme is tested in a Rapid Control Prototyping (RCP) system based on Digital Signal Processing (DSP) for dSPACE platform. The closed loop system shows adequate performance. The experimental and simulation results match. The main contribution of this paper is to introduce the load estimator by means of LMS, to make ZAD and FPIC control feasible in load variation conditions. In addition, comparison results for controlled buck converter with SMC, PID and ZAD-FPIC control techniques are shown.

  1. Hierarchical Control Strategy for the Cooperative Braking System of Electric Vehicle

    Science.gov (United States)

    Peng, Jiankun; He, Hongwen; Guo, Hongqiang

    2015-01-01

    This paper provides a hierarchical control strategy for cooperative braking system of an electric vehicle with separated driven axles. Two layers are defined: the top layer is used to optimize the braking stability based on two sliding mode control strategies, namely, the interaxle control mode and signal-axle control strategies; the interaxle control strategy generates the ideal braking force distribution in general braking condition, and the single-axle control strategy can ensure braking safety in emergency braking condition; the bottom layer is used to maximize the regenerative braking energy recovery efficiency with a reallocated braking torque strategy; the reallocated braking torque strategy can recovery braking energy as much as possible in the premise of meeting battery charging power. The simulation results show that the proposed hierarchical control strategy is reasonable and can adapt to different typical road surfaces and load cases; the vehicle braking stability and safety can be guaranteed; furthermore, the regenerative braking energy recovery efficiency can be improved. PMID:26236772

  2. Hierarchical Control Strategy for the Cooperative Braking System of Electric Vehicle.

    Science.gov (United States)

    Peng, Jiankun; He, Hongwen; Liu, Wei; Guo, Hongqiang

    2015-01-01

    This paper provides a hierarchical control strategy for cooperative braking system of an electric vehicle with separated driven axles. Two layers are defined: the top layer is used to optimize the braking stability based on two sliding mode control strategies, namely, the interaxle control mode and signal-axle control strategies; the interaxle control strategy generates the ideal braking force distribution in general braking condition, and the single-axle control strategy can ensure braking safety in emergency braking condition; the bottom layer is used to maximize the regenerative braking energy recovery efficiency with a reallocated braking torque strategy; the reallocated braking torque strategy can recovery braking energy as much as possible in the premise of meeting battery charging power. The simulation results show that the proposed hierarchical control strategy is reasonable and can adapt to different typical road surfaces and load cases; the vehicle braking stability and safety can be guaranteed; furthermore, the regenerative braking energy recovery efficiency can be improved.

  3. Hierarchical Control Strategy for the Cooperative Braking System of Electric Vehicle

    Directory of Open Access Journals (Sweden)

    Jiankun Peng

    2015-01-01

    Full Text Available This paper provides a hierarchical control strategy for cooperative braking system of an electric vehicle with separated driven axles. Two layers are defined: the top layer is used to optimize the braking stability based on two sliding mode control strategies, namely, the interaxle control mode and signal-axle control strategies; the interaxle control strategy generates the ideal braking force distribution in general braking condition, and the single-axle control strategy can ensure braking safety in emergency braking condition; the bottom layer is used to maximize the regenerative braking energy recovery efficiency with a reallocated braking torque strategy; the reallocated braking torque strategy can recovery braking energy as much as possible in the premise of meeting battery charging power. The simulation results show that the proposed hierarchical control strategy is reasonable and can adapt to different typical road surfaces and load cases; the vehicle braking stability and safety can be guaranteed; furthermore, the regenerative braking energy recovery efficiency can be improved.

  4. Part load performance of air-cooled centrifugal chillers with variable speed condenser fan control

    Energy Technology Data Exchange (ETDEWEB)

    Yu, F.W.; Chan, K.T. [Department of Building Services Engineering, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong (China)

    2007-11-15

    Air-cooled centrifugal chillers are commonly used in commercial buildings but their performance analysis is lacking. This paper investigates the part load performance of the chillers via a thermodynamic model. The model was validated using a wide range of operating data from an existing chiller with specific settings of outdoor temperature and condensing pressure in controlling the condensing temperature. The validated model was developed specifically to ascertain the maximum coefficient of performance of chiller (COP) together with the strategy for optimizing the condensing temperature under various operating conditions. It is found that the highest COP occurs at a part load ratio (PLR) of 0.71-0.84, depending on the outdoor temperature and the control of condensing temperature, rather than at full load. Yet the chillers operating at such part load conditions will cause extra energy used for the early staging of chilled water pumps. To minimize the overall chiller plant energy consumption, it is still preferable to implement chiller sequencing based on the full load condition than on the aforementioned PLRs. The results of this paper present criteria for implementing low-energy strategies for operating air-cooled chillers satisfying a given building cooling load profile. (author)

  5. Climate control loads prediction of electric vehicles

    International Nuclear Information System (INIS)

    Zhang, Ziqi; Li, Wanyong; Zhang, Chengquan; Chen, Jiangping

    2017-01-01

    Highlights: • A model of vehicle climate control loads is proposed based on experiments. • Main climate control loads of the modeled vehicle are quantitatively analyzed. • Range reductions of the modeled vehicle under different conditions are simulated. - Abstract: A new model of electric vehicle climate control loads is provided in this paper. The mathematical formulations of the major climate control loads are developed, and the coefficients of the formulations are experimentally determined. Then, the detailed climate control loads are analyzed, and the New European Driving Cycle (NEDC) range reductions due to these loads are calculated under different conditions. It is found that in an electric vehicle, the total climate control loads vary with the vehicle speed, HVAC mode and blower level. The ventilation load is the largest climate control load, followed by the solar radiation load. These two add up to more than 80% of total climate control load in summer. The ventilation load accounts for 70.7–83.9% of total heating load under the winter condition. The climate control loads will cause a 17.2–37.1% reduction of NEDC range in summer, and a 17.1–54.1% reduction in winter, compared to the AC off condition. The heat pump system has an advantage in range extension. A heat pump system with an average heating COP of 1.7 will extend the range by 7.6–21.1% based on the simulation conditions.

  6. Balance control of grid currents for UPQC under unbalanced loads based on matching-ratio compensation algorithm

    DEFF Research Database (Denmark)

    Zhao, Xiaojun; Zhang, Chunjiang; Chai, Xiuhui

    2018-01-01

    In three-phase four-wire systems, unbalanced loads can cause grid currents to be unbalanced, and this may cause the neutral point potential on the grid side to shift. The neutral point potential shift will worsen the control precision as well as the performance of the threephase four-wire unified...... fluctuations, and elaborates the interaction between unbalanced grid currents and DC bus voltage fluctuations; two control strategies of UPQC under three-phase stationary coordinate based on the MCA are given, and finally, the feasibility and effectiveness of the proposed control strategy are verified...... power quality conditioner (UPQC), and it also leads to unbalanced three-phase output voltage, even causing damage to electric equipment. To deal with unbalanced loads, this paper proposes a matching-ratio compensation algorithm (MCA) for the fundamental active component of load currents...

  7. Conceptual framework for load controlling : with demand reduction bidding & consumer retention

    NARCIS (Netherlands)

    Babar, M.; Ahamed, I.; Al-Ammar, E.A.

    2013-01-01

    Advancement in demand side management strategies enables smart grid to cope with the increasing energy demand and provide economic benefit to all of its stakeholders. Moreover, emerging concept of smart pricing and advances in load control and communication generate new business opportunities as a

  8. Argos: Residential end-use simulation model for load management strategy analysis

    International Nuclear Information System (INIS)

    Capasso, A.; Lamedica, R.; Prudenzi, A.

    1992-01-01

    In recent years, load management (LM) strategies, aimed at the optimization of available energy resources, as well as, the reduction of investments for new power plants, have been applied worldwide in residential end-use assessments. However, the forecasting of LM strategy impacts on the residential sector is very complex because it is based on a preliminary evaluation of the customers' proclivity to adapt their load characteristics to utility aims. In order to reduce load analysis requirements, which are substantial due to the need for thorough statistical analyses, complex field tests and measurements, the availability of models taking into account customer behavioural aspects is of paramount importance. This paper illustrates a simulation model which allows the performance of numerical evaluations concerning the effectiveness of some LM strategies applied to a residential end-use area load profile as previously determined by the aggregation of the contributions of individual households. This model enabled the evaluation of the impact, on the load profile, of a time-of-day tariff such as that recently introduced in Italy

  9. Reactor control device for controlling load of nuclear power plant

    International Nuclear Information System (INIS)

    Hirota, Tadakuni; Yokoyama, Terukuni; Masuda, Jiro.

    1981-01-01

    Purpose: To improve the load follow-up capacity of a nuclear reactor by automatically controlling the width of the not-sensing band of a control rod inserting and removing discriminator circuit. Constitution: When load control operations such as automatic load control, automatic frequency control, governor free operation and so forth are conducted, the width of a not sensing band of a control rod inserting and removing discriminator circuit is ao automatically controlled that the not sensing band width may return to ordinary value in a normal operation by avoiding the fast repetition of inserting and removing control rods by increasing the width of the insensing band if the period of a control deviation signal produced due to the variation in the load is quickly repeated and varied in correspondence to the control deviation signal. That is, a circuit for varying the insensing band of the control circuit for driving a control mechanism is provided to reduce the amount of driving the control rods in a load control operation and to reduce the strain of the power distribution of the nuclear reactor, thereby improving the load control capacity. (Yoshihara, H.)

  10. Control strategy for energy-efficient bipedal walking with variable leg stiffness

    NARCIS (Netherlands)

    Visser, L.C.; Stramigioli, Stefano; Carloni, Raffaella

    In this work, we propose a hybrid model for a bipedal walker with controlled variable leg stiffness, and a control strategy for stable gait control. The control reference is a passive gait of the limit-case bipedal spring-loaded inverted pendulum model with massless feet, ensuring that the gait is

  11. DC Microgrids–Part I: A Review of Control Strategies and Stabilization Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Dragicevic, Tomislav; Lu, Xiaonan; Vasquez, Juan; Guerrero, Josep

    2015-01-01

    This paper presents a review of control strategies, stability analysis, and stabilization techniques for dc microgrids (MGs). Overall control is systematically classified into local and coordinated control levels according to respective functionalities in each level. As opposed to local control, which relies only on local measurements, some line of communication between units needs to be made available in order to achieve the coordinated control. Depending on the communication method, three basic coordinated control strategies can be distinguished, i.e., decentralized, centralized, and distributed control. Decentralized control can be regarded as an extension of the local control since it is also based exclusively on local measurements. In contrast, centralized and distributed control strategies rely on digital communication technologies. A number of approaches using these three coordinated control strategies to achieve various control objectives are reviewed in this paper. Moreover, properties of dc MG dynamics and stability are discussed. This paper illustrates that tightly regulated point-of-load converters tend to reduce the stability margins of the system since they introduce negative impedances, which can potentially oscillate with lightly damped power supply input filters. It is also demonstrated that how the stability of the whole system is defined by the relationship of the source and load impedances, referred to as the minor loop gain. Several prominent specifications for the minor loop gain are reviewed. Finally, a number of active stabilization techniques are presented.

  12. Parameterized Disturbance Observer Based Controller to Reduce Cyclic Loads of Wind Turbine

    Directory of Open Access Journals (Sweden)

    Raja M. Imran

    2018-05-01

    Full Text Available This paper is concerned with bump-less transfer of parameterized disturbance observer based controller with individual pitch control strategy to reduce cyclic loads of wind turbine in full load operation. Cyclic loads are generated due to wind shear and tower shadow effects. Multivariable disturbance observer based linear controllers are designed with objective to reduce output power fluctuation, tower oscillation and drive-train torsion using optimal control theory. Linear parameterized controllers are designed by using a smooth scheduling mechanism between the controllers. The proposed parameterized controller with individual pitch was tested on nonlinear Fatigue, Aerodynamics, Structures, and Turbulence (FAST code model of National Renewable Energy Laboratory (NREL’s 5 MW wind turbine. The closed-loop system performance was assessed by comparing the simulation results of proposed controller with a fixed gain and parameterized controller with collective pitch for full load operation of wind turbine. Simulations are performed with step wind to see the behavior of the system with wind shear and tower shadow effects. Then, turbulent wind is applied to see the smooth transition of the controllers. It can be concluded from the results that the proposed parameterized control shows smooth transition from one controller to another controller. Moreover, 3p and 6p harmonics are well mitigated as compared to fixed gain DOBC and parameterized DOBC with collective pitch.

  13. Impact of sampling strategy on stream load estimates in till landscape of the Midwest

    Science.gov (United States)

    Vidon, P.; Hubbard, L.E.; Soyeux, E.

    2009-01-01

    Accurately estimating various solute loads in streams during storms is critical to accurately determine maximum daily loads for regulatory purposes. This study investigates the impact of sampling strategy on solute load estimates in streams in the US Midwest. Three different solute types (nitrate, magnesium, and dissolved organic carbon (DOC)) and three sampling strategies are assessed. Regardless of the method, the average error on nitrate loads is higher than for magnesium or DOC loads, and all three methods generally underestimate DOC loads and overestimate magnesium loads. Increasing sampling frequency only slightly improves the accuracy of solute load estimates but generally improves the precision of load calculations. This type of investigation is critical for water management and environmental assessment so error on solute load calculations can be taken into account by landscape managers, and sampling strategies optimized as a function of monitoring objectives. ?? 2008 Springer Science+Business Media B.V.

  14. Feedforward control strategy for the state-decoupling Stand-alone UPS with LC output filter

    DEFF Research Database (Denmark)

    Lu, Jinghang; Savaghebi, Mehdi; Guerrero, Josep M.

    2017-01-01

    . In order to further increase the load current disturbance rejection capability of the state-decoupling in UPS system, a feedforward control strategy is proposed. In addition, the design principle for the current and voltage regulators are discussed. Simulation and experimental results are provided......In this paper, the disturbance rejection performance of the cascaded control strategy for UPS system is investigated. The comparison of closed loop system performance between conventional cascaded control (CCC) strategy and state-decoupling cascaded control (SDCC) strategy are further explored...

  15. Design of an Internal Model Control strategy for single-phase grid-connected PWM inverters and its performance analysis with a non-linear local load and weak grid.

    Science.gov (United States)

    Chaves, Eric N; Coelho, Ernane A A; Carvalho, Henrique T M; Freitas, Luiz C G; Júnior, João B V; Freitas, Luiz C

    2016-09-01

    This paper presents the design of a controller based on Internal Model Control (IMC) applied to a grid-connected single-phase PWM inverter. The mathematical modeling of the inverter and the LCL output filter, used to project the 1-DOF IMC controller, is presented and the decoupling of grid voltage by a Feedforward strategy is analyzed. A Proportional - Resonant Controller (P+Res) was used for the control of the same plant in the running of experimental results, thus moving towards the discussion of differences regarding IMC and P+Res performances, which arrived at the evaluation of the proposed control strategy. The results are presented for typical conditions, for weak-grid and for non-linear local load, in order to verify the behavior of the controller against such situations. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.

  16. Effects of External Loads on Human Head Movement Control Systems

    Science.gov (United States)

    Nam, M. H.; Choi, O. M.

    1984-01-01

    The central and reflexive control strategies underlying movements were elucidated by studying the effects of external loads on human head movement control systems. Some experimental results are presented on dynamic changes weigh the addition of aviation helmet (SPH4) and lead weights (6 kg). Intended time-optimal movements, their dynamics and electromyographic activity of neck muscles in normal movements, and also in movements made with external weights applied to the head were measured. It was observed that, when the external loads were added, the subject went through complex adapting processes and the head movement trajectory and its derivatives reached steady conditions only after transient adapting period. The steady adapted state was reached after 15 to 20 seconds (i.e., 5 to 6 movements).

  17. A design of cascade control system and adaptive load compensator for battery/ultracapacitor hybrid energy storage-based direct current microgrid

    International Nuclear Information System (INIS)

    Pavković, Danijel; Lobrović, Mihael; Hrgetić, Mario; Komljenović, Ante

    2016-01-01

    Highlights: • Battery/ultracapacitor storage is considered for a direct-current microgrid. • Microgrid voltage cascade control system with load compensator is designed. • Current references are allocated so that ultracapacitor takes on transient loads. • Adaptive Kalman filter-based estimator is used for indirect load compensation. • Control strategy has been verified on a downscaled hardware-in-the-loop setup. - Abstract: A control system design based on an actively-controlled battery/ultracapacitor hybrid energy storage system suitable for direct current microgrid energy management purposes is presented in this paper. The proposed cascade control system arrangement is based on the superimposed proportional–integral voltage controller designed according to Damping Optimum criterion and a zero-pole canceling feed-forward load compensator aimed at voltage excursion suppression under variable load conditions. The superimposed controller commands the inner battery and ultracapacitor current control loops through a dynamic current reference distribution scheme, wherein the ultracapacitor takes on the highly-dynamic (transient) current demands, and the battery covers for steady-state loads. In order to avoid deep discharges of the ultracapacitor module, it is equipped with an auxiliary state-of-charge controller. Finally, for those applications where load is not measured, an adaptive Kalman filter-based load compensator is proposed and tested. The presented control strategy has been implemented on the low-cost industrial controller unit, and its effectiveness has been verified by means of simulations and experiments for the cases of abrupt load changes and quasi-stochastic load profiles using a downscaled battery/ultracapacitor hardware-in-the-loop experimental setup.

  18. Inner-Learning Mechanism Based Control Scheme for Manipulator with Multitasking and Changing Load

    Directory of Open Access Journals (Sweden)

    Fangzheng Xue

    2014-05-01

    Full Text Available With the rapid development of robot technology and its application, manipulators may face complex tasks and dynamic environments in the coming future, which leads to two challenges of control: multitasking and changing load. In this paper, a novel multicontroller strategy is presented to meet such challenges. The presented controller is composed of three parts: subcontrollers, inner-learning mechanism, and switching rules. Each subcontroller is designed with self-learning skills to fit the changing load under a special task. When a new task comes, switching rule reselects the most suitable subcontroller as the working controller to handle current task instead of the older one. Inner-learning mechanism makes the subcontrollers learn from the working controller when load changes so that the switching action causes smaller tracking error than the traditional switch controller. The results of the simulation experiments on two-degree manipulator show the proposed method effect.

  19. Cognitive Load of Learner Control: Extraneous or Germane Load?

    Directory of Open Access Journals (Sweden)

    Mieke Vandewaetere

    2013-01-01

    Full Text Available Computer-based learning environments become more tailored when learners can exert control over one or more parts of the learning process. Learner control (LC demands additional efforts of learners because, in addition to learning, they also have to monitor that learning. As a consequence, LC may cause additional cognitive load and even cognitive overload. The central question in this study is what type of cognitive load is induced by LC and whether the experienced load is related to learning outcomes. For this study, half of the students had control over task selection, while the other half had not. Within each condition, students were assigned to a single treatment, with the primary task to solely focus on the learning content, and a dual treatment, comprising a primary task and a secondary task. The results indicate that LC did not impose higher cognitive load as measured by secondary task scores and mental effort ratings.

  20. Comprehensive Review on Divisible Load Theory: Concepts, Strategies, and Approaches

    Directory of Open Access Journals (Sweden)

    Shamsollah Ghanbari

    2014-01-01

    Full Text Available There is extensive literature concerning the divisible load theory. The divisible load theory is mainly applied for scheduling in the area of distributed computing. It is based on the fact that the load can be divided into some arbitrarily independent parts, in which each part can be processed independently by a processor. This paper reviews the literature concerning the divisible load theory, while focusing on the details of the basic concepts, approaches, strategies, typologies, and open problems.

  1. Anti-Swing Control of Suspended Loads on Shipboard Robotic Cranes

    Directory of Open Access Journals (Sweden)

    Jackrit Suthakorn

    2005-02-01

    Full Text Available Currently, the speed at which materials can be transferred between ships at sea is limited by sea conditions. Rough sea conditions cause the payload to swing making load transfer difficult and time-consuming. The objective of this research is to develop a real-time, command compensating control for reducing sea state induced payload swing for shipboard robotic cranes. The future use of this control strategy will be to facilitate faster "ship-to-ship" payload transfer in rough sea conditions. In this study, only the sea-induced rotational motion of the ship is considered, since it is assumed that a station-keeping control maintains a constant position of the ship. This rotational motion is modelled using pitch-yaw-roll Euler angles. The shipboard robotic crane is modelled as a spherical pendulum attached to a three-degree-of-freedom manipulator. The three degrees-of-freedom are azimuth (rotation about an axis normal to the ship's deck, elevation (rotation about an axis parallel with the ship's deck, also referred to as luffing, and lift-line length. An inverse kinematics based approach and a sliding mode control strategy are explored. Both approaches use the azimuth and the elevation capability of the crane manipulator to maintain a horizontal position of the suspended load to reduce sea-induced payload sway.

  2. Load power device, system and method of load control and management employing load identification

    Science.gov (United States)

    Yang, Yi; Luebke, Charles John; Schoepf, Thomas J.

    2018-01-09

    A load power device includes a power input, at least one power output for at least one load, a plurality of sensors structured to sense voltage and current at the at least one power output, and a processor. The processor provides: (a) load identification based upon the sensed voltage and current, and (b) load control and management based upon the load identification.

  3. Testing a two-scale focused conservation strategy for reducing phosphorus and sediment loads from agricultural watersheds

    Science.gov (United States)

    Carvin, Rebecca; Good, Laura W.; Fitzpatrick, Faith A.; Diehl, Curt; Songer, Katherine; Meyer, Kimberly J.; Panuska, John C.; Richter, Steve; Whalley, Kyle

    2018-01-01

    This study tested a focused strategy for reducing phosphorus (P) and sediment loads in agricultural streams. The strategy involved selecting small watersheds identified as likely to respond relatively quickly, and then focusing conservation practices on high-contributing fields within those watersheds. Two 5,000 ha (12,360 ac) watersheds in the Driftless Area of south central Wisconsin, previously ranked in the top 6% of similarly sized Wisconsin watersheds for expected responsiveness to conservation efforts to reduce high P and sediment loads, were chosen for the study. The stream outlets from both watersheds were monitored from October of 2006 through September of 2016 for streamflow and concentrations of sediment, total P, and, beginning in October of 2009, total dissolved P. Fields and pastures having the highest potential P delivery to the streams in each watershed were identified using the Wisconsin P Index (Good et al. 2012). After three years of baseline monitoring (2006 to 2009), farmers implemented both field- and farm-based conservation practices in one watershed (treatment) as a means to reduce sediment and P inputs to the stream from the highest contributing areas, whereas there were no out-of-the-ordinary conservation efforts in the second watershed (control). Implementation occurred primarily in 2011 and 2012. In the four years following implementation of conservation practices (2013 through 2016), there was a statistically significant reduction in storm-event suspended sediment loads in the treatment watershed compared to the control watershed when the ground was not frozen (p = 0.047). While there was an apparent reduction in year-round suspended sediment event loads, it was not statistically significant at the 95% confidence level (p = 0.15). Total P loads were significantly reduced for runoff events (p < 0.01) with a median reduction of 50%. Total P and total dissolved P concentrations for low-flow conditions were also significantly reduced (p

  4. Hybrid Droop Control Strategy Applied to Grid-Supporting Converters in DC Microgrids

    DEFF Research Database (Denmark)

    Han, Renke; Meng, Lexuan; Guerrero, Josep M.

    2017-01-01

    The paper proposes a hybrid droop control strategy to enhance the stability and increase maximum constant power loads (CPLs) capability of DC microgrids in a realistic scenario. By capturing the detailed model of inner control loops and hybrid droop control and general dc MG topology, a thorough...

  5. A dynamic switching strategy for air-conditioning systems operated in light-thermal-load conditions

    International Nuclear Information System (INIS)

    Lin, Jin-Long; Yeh, T.-J.; Hwang, Wei-Yang

    2009-01-01

    Recently, modern air-conditioners have begun to incorporate variable-speed compressors and variable-opening expansion valves, together with feedback control to improve the performance and energy efficiency. However, for the compressor there usually exists a low-speed limit below which its speed can not be continuously modulated unless it is completely turned off. When the air-conditioning system is operated in light-thermal-load conditions, the low-speed limit causes the compressor to run in an on-off manner which can significantly degrade the performance and efficiency. In this paper, a dynamic switching strategy is proposed for such scenarios. The strategy is basically an integration of a cascading control structure, an intuitive switching strategy, and a dynamic compensator. While the control structure provides the nominal performance, the intuitive switching strategy and the dynamic compensator together can account for the compressor's low-speed limitation. Theoretical analysis reveals that when the output matrix of the dynamic compensator is chosen properly, the proposed strategy can effectively reduce the output error caused by the on-off operation of the compressor. Experiments also demonstrate that the proposed strategy can simultaneously provide better regulation for the indoor temperature and improve the energy efficiency at steady state.

  6. Achieving clean and efficient engine operation up to full load by combining optimized RCCI and dual-fuel diesel-gasoline combustion strategies

    International Nuclear Information System (INIS)

    Benajes, Jesús; García, Antonio; Monsalve-Serrano, Javier; Boronat, Vicente

    2017-01-01

    Highlights: • Optimized dual-fuel strategy to cover the whole engine load-speed map. • EURO VI NOx levels up to 14 bar IMEP with fully and highly premixed RCCI strategies. • Dual-fuel provides up to 7% higher efficiency than CDC if urea consumption is considered. - Abstract: This experimental work investigates the capabilities of the reactivity controlled compression ignition combustion concept to be operated in the whole engine map and discusses its benefits when compared to conventional diesel combustion. The experiments were conducted using a single-cylinder medium-duty diesel engine fueled with regular gasoline and diesel fuels. The main modification on the stock engine architecture was the addition of a port fuel injector in the intake manifold. In addition, with the aim of extending the reactivity controlled compression ignition operating range towards higher loads, the piston bowl volume was increased to reduce the compression ratio of the engine from 17.5:1 (stock) down to 15.3:1. To allow the dual-fuel operation over the whole engine map without exceeding the mechanical limitations of the engine, an optimized dual-fuel combustion strategy is proposed in this research. The combustion strategy changes as the engine load increases, starting from a fully premixed reactivity controlled compression ignition combustion up to around 8 bar IMEP, then switching to a highly premixed reactivity controlled compression ignition combustion up to 15 bar IMEP, and finally moving to a mainly diffusive dual-fuel combustion to reach the full load operation. The engine mapping results obtained using this combustion strategy show that reactivity controlled compression ignition combustion allows fulfilling the EURO VI NOx limit up to 14 bar IMEP. Ultra-low soot emissions are also achieved when the fully premixed combustion is promoted, however, the soot levels rise notably as the combustion strategy moves to a less premixed pattern. Finally, the direct comparison of

  7. Research on Control Strategy of Free-Piston Stirling Power Generating System

    Directory of Open Access Journals (Sweden)

    Jigui Zheng

    2017-10-01

    Full Text Available As a clean and fuel adaptive alternative power plant, the Stirling power generating system has drawn attention of experts and scholars in the energy field. In practical application, the instability of free-piston Stirling power generating system caused by abrupt load change is an inevitable problem. Thus, methods to improve the output frequency response and stability of the free-piston Stirling power generating system are necessary. The model of free-piston Stirling power generating system is built by isothermal analysis firstly, and the initial control strategy based on given voltage system is put forward. To further improve the performance of power system, a current feedback decoupling control strategy is proposed, and the mathematical model is established. The influence of full decoupled quadrature-direct (d-q axis currents is analyzed with respect to the output voltage adjusting time and fluctuation amplitude under the variations of piston displacement and output load. The simulation results show that the system performance is significantly improved, but the dynamic regulation lags caused by the decoupled current control still exist. To solve this problem and improve the performance of decoupled-state feedback current control that relies on parameter accuracy, internal model control based on sliding mode (IMC-SM current decoupling control strategy is proposed, the system model is established, and then the performance of voltage ripple in generating mode is improved. Finally, the test bench is built, and the steady state and transient voltage control performances are tested. The feasibility and priority of the control strategy is verified by experiment and simulation results.

  8. Optimal robust control strategy of a solid oxide fuel cell system

    Science.gov (United States)

    Wu, Xiaojuan; Gao, Danhui

    2018-01-01

    Optimal control can ensure system safe operation with a high efficiency. However, only a few papers discuss optimal control strategies for solid oxide fuel cell (SOFC) systems. Moreover, the existed methods ignore the impact of parameter uncertainty on system instantaneous performance. In real SOFC systems, several parameters may vary with the variation of operation conditions and can not be identified exactly, such as load current. Therefore, a robust optimal control strategy is proposed, which involves three parts: a SOFC model with parameter uncertainty, a robust optimizer and robust controllers. During the model building process, boundaries of the uncertain parameter are extracted based on Monte Carlo algorithm. To achieve the maximum efficiency, a two-space particle swarm optimization approach is employed to obtain optimal operating points, which are used as the set points of the controllers. To ensure the SOFC safe operation, two feed-forward controllers and a higher-order robust sliding mode controller are presented to control fuel utilization ratio, air excess ratio and stack temperature afterwards. The results show the proposed optimal robust control method can maintain the SOFC system safe operation with a maximum efficiency under load and uncertainty variations.

  9. A Voltage and Frequency Control Strategy for Stand-Alone Full Converter Wind Energy Conversion Systems

    Directory of Open Access Journals (Sweden)

    Andrés Peña Asensio

    2018-02-01

    Full Text Available This paper addresses the design and analysis of a voltage and frequency control (VFC strategy for full converter (FC-based wind energy conversion systems (WECSs and its applicability for the supply of an isolated load. When supplying an isolated load, the role of the back-to-back converters in the FC must change with respect to a grid-connected application. Voltage and frequency are established by the FC line side converter (LSC, while the generator side converter (GSC is responsible for maintaining constant voltage in the DC link. Thus, the roles of the converters in the WECS are inverted. Under such control strategies, the LSC will automatically supply the load power and hence, in order to maintain a stable operation of the WECS, the wind turbine (WT power must also be controlled in a load-following strategy. The proposed VFC is fully modelled and a stability analysis is performed. Then, the operation of the WECS under the proposed VFC is simulated and tested on a real-time test bench, demonstrating the performance of the VFC for the isolated operation of the WECS.

  10. Direct harmonic voltage control strategy for shunt active power filter

    DEFF Research Database (Denmark)

    Munir, Hafiz Mudassir; Zou, JianXiao; Xie, Chuan

    2017-01-01

    generation system (DPGS) where the nonlinear loads are highly dispersed. Local harmonic voltage detection based Resistive-APF (R-APF) seems more suitable to be applied in the DPGS, however, R-APF suffers from poor compensation performance and difficulty of parameter tuning. In this paper, a direct harmonic...... voltage control strategy for the S-APF is proposed with local point of common coupling (PCC) voltage detection only. The control strategy design procedure is given in detail. Simulation is conducted in Matlab/Simulink to compare the performance between the R-APF and the proposed method. The results...

  11. The Optimization dispatching of Micro Grid Considering Load Control

    Science.gov (United States)

    Zhang, Pengfei; Xie, Jiqiang; Yang, Xiu; He, Hongli

    2018-01-01

    This paper proposes an optimization control of micro-grid system economy operation model. It coordinates the new energy and storage operation with diesel generator output, so as to achieve the economic operation purpose of micro-grid. In this paper, the micro-grid network economic operation model is transformed into mixed integer programming problem, which is solved by the mature commercial software, and the new model is proved to be economical, and the load control strategy can reduce the charge and discharge times of energy storage devices, and extend the service life of the energy storage device to a certain extent.

  12. Decentralized Electric Vehicle Charging Strategies for Reduced Load Variation and Guaranteed Charge Completion in Regional Distribution Grids

    Directory of Open Access Journals (Sweden)

    Weige Zhang

    2017-01-01

    Full Text Available A novel, fully decentralized strategy to coordinate charge operation of electric vehicles is proposed in this paper. Based on stochastic switching control of on-board chargers, this strategy ensures high-efficiency charging, reduces load variations to the grid during charging periods, achieves charge completion with high probability, and accomplishes approximate “valley-filling”. Further improvements on the core strategy, including individualized power management, adaptive strategies, and battery support systems, are introduced to further reduce power fluctuation variances and to guarantee charge completion. Stochastic analysis is performed to establish the main properties of the strategies and to quantitatively show the performance improvements. Compared with the existing decentralized charging strategies, the strategies proposed in this paper can be implemented without any information exchange between grid operators and electric vehicles (EVs, resulting in a communications cost reduction. Additionally, it is shown that by using stochastic charging rules, a grid-supporting battery system with a very small energy capacity can achieve substantial reduction of EV load fluctuations with high confidence. An extensive set of simulations and case studies with real-world data are used to demonstrate the benefits of the proposed strategies.

  13. Implementation and comparative study of control strategies for an isolated DFIG based WECS

    Science.gov (United States)

    Bouchiba, Nouha; Barkia, Asma; Sallem, Souhir; Chrifi-Alaoui, Larbi; Drid, Saïd; Kammoun, M. B. A.

    2017-10-01

    Nowadays, a global interest for renewable energy sources has been growing intensely. In particular, a wind energy has become the most popular. In case of autonomous systems, wind energy conversion system (WECS) based on a double fed induction generator (DFIG) is widely used. In this paper, in order to control the stand-alone system outputs under wind speed and load variations, three kinds of nonlinear control strategies have been proposed, applied and compared, such as: Classical PI controller, Back-Stepping and Sliding Mode controllers. A series of experiments have been conducted to evaluate and to compare the developed controllers' dynamic performances under load demand and speed variations. The design and the implementation of different control strategies to a 1.5kW doubly fed induction machine is carried out using a dSpace DS1104 card based on MATLAB/Simulink environment. Experimental results are presented to show the validity of the implemented controllers and demonstrate the effectiveness of each controller compared with others.

  14. Supervisory Control Strategy Development

    International Nuclear Information System (INIS)

    Gary D Storrick; Bojan Petrovic

    2007-01-01

    Task 4 of this collaborative effort between ORNL, Brazil, and Westinghouse for the International Nuclear Energy Research Initiative entitled 'Development of Advanced Instrumentation and Control for an Integrated Primary System Reactor' focused on the design of the hierarchical supervisory control for multiple-module units. The state of the IRIS plant design--specifically, the lack of a detailed secondary system design--made developing a detailed hierarchical control difficult at this time. However, other simultaneous and ongoing efforts have contributed to providing the needed information. This report summarizes the results achieved under Task 4 of this Financial Assistance Award. Section 1.2 describes the scope of this effort. Section 2 discusses the IRIS control functions. Next, it briefly reviews the current control concepts, and then reviews the maneuvering requirements for the IRIS plant. It closes by noting the benefits that automated sequences have in reducing operator workload. Section 3 examines reactor loading in the frequency domain to establish some guidelines for module operation, paying particular attention to strategies for using process steam for desalination and/or district heating. The final subsection discusses the implications for reactor control, and argues that using the envisioned percentage (up to 10%) of the NSSS thermal output for these purposes should not significantly affect the NSSS control strategies. Section 4 uses some very general economic assumptions to suggest how one should approach multi-module operation. It concludes that the well-known algorithms used for economic dispatching could be used to help manage a multi-unit IRIS site. Section 5 addresses the human performance factors of multi-module operation. Section 6 summarizes our conclusions

  15. Hybrid Robust Control Law with Disturbance Observer for High-Frequency Response Electro-Hydraulic Servo Loading System

    Directory of Open Access Journals (Sweden)

    Zhiqing Sheng

    2016-04-01

    Full Text Available Addressing the simulating issue of the helicopter-manipulating booster aerodynamic load with high-frequency dynamic load superimposed on a large static load, this paper studies the design of the robust controller for the electro-hydraulic loading system to realize the simulation of this kind of load. Firstly, the equivalent linear model of the electro-hydraulic loading system under assumed parameter uncertainty is established. Then, a hybrid control scheme is proposed for the loading system. This control scheme consists of a constant velocity feed-forward compensator, a robust inner loop compensator based on disturbance observer and a robust outer loop feedback controller. The constant velocity compensator eliminates most of the extraneous force at first, and then the double-loop cascade composition control strategy is employed to design the compensated system. The disturbance observer–based inner loop compensator further restrains the disturbances including the remaining extraneous force, and makes the actual plant tracking a nominal model approximately in a certain frequency range. The robust outer loop controller achieves the desired force-tracking performance, and guarantees system robustness in the high frequency region. The optimized low-pass filter Q(s is designed by using the H∞ mixed sensitivity optimization method. The simulation results show that the proposed hybrid control scheme and controller can effectively suppress the extraneous force and improve the robustness of the electro-hydraulic loading system.

  16. Emergency Load Shedding Strategy Based on Sensitivity Analysis of Relay Operation Margin against Cascading Events

    DEFF Research Database (Denmark)

    Liu, Zhou; Chen, Zhe; Sun, Haishun Sun

    2012-01-01

    the runtime emergent states of related system component. Based on sensitivity analysis between the relay operation margin and power system state variables, an optimal load shedding strategy is applied to adjust the emergent states timely before the unwanted relay operation. Load dynamics is also taken...... into account to compensate load shedding amount calculation. And the multi-agent technology is applied for the whole strategy implementation. A test system is built in real time digital simulator (RTDS) and has demonstrated the effectiveness of the proposed strategy.......In order to prevent long term voltage instability and induced cascading events, a load shedding strategy based on the sensitivity of relay operation margin to load powers is discussed and proposed in this paper. The operation margin of critical impedance backup relay is defined to identify...

  17. Preliminary study of S-CO{sub 2} cycle control logic for part load operation

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Yoonhan; Lee, Jeong Ik [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2016-05-15

    The benefits of S-CO{sub 2} cycle are relatively high efficiency under the mild turbine inlet temperature region, simple layout configuration and small foot-print. In addition, the safety of the SFR system can be inherently enhanced as the violent sodium-water reaction can be substituted with the mild sodium-CO{sub 2} reaction. 75MWe S-CO{sub 2} recompression cycle with radial type turbomachineries and PCHE was designed. Under various part load conditions (30-100% thermal load), off-design performance of the designed system was assessed, and different control logics were first tested. It was identified that the inventory control strategy is the most efficient logic for the part load operation. In the system operation, the compressor surge condition is seriously considered and controlled to avoid the system damage.

  18. A Flexible Load Control Strategy for Distribution Network to Reduce the Line Losses and to Eliminate the Transmission Congestion

    Directory of Open Access Journals (Sweden)

    Beibei Wang

    2017-01-01

    Full Text Available There are many uncertain factors in the modern distribution network, including the access of renewable energy sources and the heavy load level. The existence of these factors has brought challenges to the stability of the power distribution network, as well as increasing the risk of exceeding transmission capacity of distribution lines. The appearance of flexible load control technology provides a new idea to solve the above problems. Air conditioners (ACs account for a great proportion of all loads. In this paper, the model of dispatching AC loads in the regional power grid is constructed, and the direct load control (DLC method is adopted to reduce the load of ACs. An improved tabu search technique is proposed to solve the problem of network dispatch in distribution systems in order to reduce the resistive line losses and to eliminate the transmission congestion in lines under normal operating conditions. The optimal node solution is obtained to find the best location and reduction capacity of ACs for load control. To demonstrate the validity and effectiveness of the proposed method, a test system is studied. The numerical results are also given in this article, which reveal that the proposed method is promising.

  19. Energy optimal control strategies for electro motors; low-cost and sensorless PWM-VSI based induction motor control. Vol. 1: Main report, appendix and annex

    Energy Technology Data Exchange (ETDEWEB)

    Abrahamsen, F

    1998-02-01

    When variable speed induction motor drives are used in applications that run at low load for long periods, energy can be saved by reducing the motor flux at low load. In this report the efficiency of 2.2 kW standard and high-efficiency motor drives are investigated experimentally with efficiency optimized and constant flux control, with sinusoidal and PWM voltage supply and with varying switching frequency. Steady-state motor models are developed and verified experimentally, and are used to analyze and develop efficiency optimizing control strategies. Four energy optimal control strategies are tested experimentally: cos({phi}) control, model-based control, off-line calculated airgap flux control and stator current/input power minimising search control. Their dynamical properties and their ability to reject load disturbances are analysed. Their ability to save energy is tested on a water pump system. For a typical predefined test-cycle the energy optimal control reduces the energy consumption with 10% compared with classical constant V/Hz control. (au)

  20. A New Strategy for Short-Term Load Forecasting

    Directory of Open Access Journals (Sweden)

    Yi Yang

    2013-01-01

    Full Text Available Electricity is a special energy which is hard to store, so the electricity demand forecasting remains an important problem. Accurate short-term load forecasting (STLF plays a vital role in power systems because it is the essential part of power system planning and operation, and it is also fundamental in many applications. Considering that an individual forecasting model usually cannot work very well for STLF, a hybrid model based on the seasonal ARIMA model and BP neural network is presented in this paper to improve the forecasting accuracy. Firstly the seasonal ARIMA model is adopted to forecast the electric load demand day ahead; then, by using the residual load demand series obtained in this forecasting process as the original series, the follow-up residual series is forecasted by BP neural network; finally, by summing up the forecasted residual series and the forecasted load demand series got by seasonal ARIMA model, the final load demand forecasting series is obtained. Case studies show that the new strategy is quite useful to improve the accuracy of STLF.

  1. Coordination and Control of Flexible Building Loads for Renewable Integration; Demonstrations using VOLTTRON

    Energy Technology Data Exchange (ETDEWEB)

    Hao, He [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Liu, Guopeng [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Huang, Sen [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Katipamula, Srinivas [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-10-31

    Renewable energy resources such as wind and solar power have a high degree of uncertainty. Large-scale integration of these variable generation sources into the grid is a big challenge for power system operators. Buildings, in which we live and work, consume about 75% of the total electricity in the United States. They also have a large capacity of power flexibility due to their massive thermal capacitance. Therefore, they present a great opportunity to help the grid to manage power balance. In this report, we study coordination and control of flexible building loads for renewable integration. We first present the motivation and background, and conduct a literature review on building-to-grid integration. We also compile a catalog of flexible building loads that have great potential for renewable integration, and discuss their characteristics. We next collect solar generation data from a photovoltaic panel on Pacific Northwest National Laboratory campus, and conduct data analysis to study their characteristics. We find that solar generation output has a strong uncertainty, and the uncertainty occurs at almost all time scales. Additional data from other sources are also used to verify our study. We propose two transactive coordination strategies to manage flexible building loads for renewable integration. We prove the theories that support the two transactive coordination strategies and discuss their pros and cons. In this report, we select three types of flexible building loads—air-handling unit, rooftop unit, and a population of WHs—for which we demonstrate control of the flexible load to track a dispatch signal (e.g., renewable generation fluctuation) using experiment, simulation, or hardware-in-the-loop study. More specifically, we present the system description, model identification, controller design, test bed setup, and experiment results for each demonstration. We show that coordination and control of flexible loads has a great potential to integrate

  2. A multi-objective control strategy for grid connection of DG (distributed generation) resources

    Energy Technology Data Exchange (ETDEWEB)

    Pouresmaeil, Edris; Montesinos-Miracle, Daniel; Bergas-Jane, Joan [Centre d' Innovacio Tecnologica en Convertidors Estatics i Accionaments (CITCEA-UPC), Departament d' Enginyeria Electrica, Universitat Politecnica de Catalunya, ETS d' Enginyeria Industrial de Barcelona (Spain); Gomis-Bellmunt, Oriol [Centre d' Innovacio Tecnologica en Convertidors Estatics i Accionaments (CITCEA-UPC), Departament d' Enginyeria Electrica, Universitat Politecnica de Catalunya, ETS d' Enginyeria Industrial de Barcelona (Spain); Catalonia Institute for Energy Research IREC, Barcelona (Spain)

    2010-12-15

    This paper presents a flexible control technique for connection of DG (distributed generation) resources to distribution networks, especially during ride-through on faulty grid. This strategy is derived from the abc/{alpha}{beta} and {alpha}{beta}/dq transformations of the ac system variables. The active and reactive currents injected by the DG source are controlled in the synchronously rotating orthogonal dq reference frame. The transformed variables are used to control the VSI (voltage source inverter) which connects the DG to the distribution network. Using a P.L.L. (phase locked loop) in circuit of proposed control technique, the angle of positive sequence has been detected, in order to synchronize the currents to the distribution network. The proposed control technique has the capability of providing active and reactive powers and harmonic currents to nonlinear loads with a fast dynamic response. Simulation results and mathematical analysis have been completed in order to achieve a reduced THD (total harmonic distortion), increased power factor and compensated load's active and reactive powers. The analyses show the high performance of this control strategy in DG applications in comparison with other existing strategies. (author)

  3. Optimal Control Allocation with Load Sensor Feedback for Active Load Suppression

    Science.gov (United States)

    Miller, Christopher

    2017-01-01

    These slide sets describe the OCLA formulation and associated algorithms as a set of new technologies in the first practical application of load limiting flight control utilizing load feedback as a primary control measurement. Slide set one describes Experiment Development and slide set two describes Flight-Test Performance.

  4. Floating wind generators offshore wind farm: Implications for structural loads and control actions

    International Nuclear Information System (INIS)

    Garcia, E.; Morant F, Quiles E.; Correcher, A.

    2009-01-01

    This paper describes the work currently carried out in the design of floating wind generators and their involvement in the future development of power generation in marine farms in depths exceeding 20 m. We discuss the main issues to be taken into account in the design of floating platforms, including the involvement of structural loads they bear. Also from a standpoint of control engineering are discussed strategies to reduce structural loads such a system to ensure adequate durability and therefore ensuring their economic viability. Finally, the abstract modeling tools for floating wind turbines that can be used in both structural design and the design of appropriate control algorithms

  5. Control strategy for permanent magnet synchronous motor with contra-rotating rotors under unbalanced loads condition

    DEFF Research Database (Denmark)

    Cheng, Shuangyin; Luo, Derong; Huang, Shoudao

    2015-01-01

    This study presents an investigation into the control of an axial-flux permanent magnet synchronous machine (PMSM) with contra-rotating rotors fed by a single inverter, which corresponds to two PMSM connected in series. In this study, the mathematic model of the PMSM with contra-rotating rotors...... water vehicle propulsions. The control strategy is implemented on a DSP 28335 processor featured hardware platform and is tested on a 1.2 kW prototype machine. Experimental results validate the correctness of the analysis and control strategy....

  6. On Advanced Control Methods toward Power Capture and Load Mitigation in Wind Turbines

    Institute of Scientific and Technical Information of China (English)

    Yuan Yuan; Jiong Tang

    2017-01-01

    This article provides a survey of recently emerged methods for wind turbine control.Multivariate control approaches to the optimization of power capture and the reduction of loads in components under time-varying turbulent wind fields have been under extensive investigation in recent years.We divide the related research activities into three categories:modeling and dynamics of wind turbines,active control of wind turbines,and passive control of wind turbines.Regarding turbine dynamics,we discuss the physical fundamentals and present the aeroelastic analysis tools.Regarding active control,we review pitch control,torque control,and yaw control strategies encompassing mathematical formulations as well as their applications toward different objectives.Our survey mostly focuses on blade pitch control,which is considered one of the key elements in facilitating load reduction while maintaining power capture performance.Regarding passive control,we review techniques such as tuned mass dampers,smart rotors,and microtabs.Possible future directions are suggested.

  7. Hysteresis Control for Shunt Active Power Filter under Unbalanced Three-Phase Load Conditions

    Directory of Open Access Journals (Sweden)

    Z. Chelli

    2015-01-01

    Full Text Available This paper focuses on a four-wire shunt active power filter (APF control scheme proposed to improve the performance of the APF. This filter is used to compensate harmonic distortion in three-phase four-wire systems. Several harmonic suppression techniques have been widely proposed and applied to minimize harmonic effects. The proposed control scheme can compensate harmonics and reactive power of the nonlinear loads simultaneously. This approach is compared to the conventional shunt APF reference compensation strategy. The developed algorithm is validated by simulation tests using MATLAB Simulink. The obtained results have demonstrated the effectiveness of the proposed scheme and confirmed the theoretical developments for balanced and unbalanced nonlinear loads.

  8. A Cyber Physical Model Based on a Hybrid System for Flexible Load Control in an Active Distribution Network

    Directory of Open Access Journals (Sweden)

    Yun Wang

    2017-02-01

    Full Text Available To strengthen the integration of the primary and secondary systems, a concept of Cyber Physical Systems (CPS is introduced to construct a CPS in Power Systems (Power CPS. The most basic work of the Power CPS is to build an integration model which combines both a continuous process and a discrete process. The advanced form of smart grid, the Active Distribution Network (ADN is a typical example of Power CPS. After designing the Power CPS model architecture and its application in ADN, a Hybrid System based model and control method of Power CPS is proposed in this paper. As an application example, ADN flexible load is modeled and controlled with ADN feeder power control by a control strategy which includes the normal condition and the underpowered condition. In this model and strategy, some factors like load power consumption and load functional demand are considered and optimized. In order to make up some of the deficiencies of centralized control, a distributed control method is presented to reduce model complexity and improve calculation speed. The effectiveness of all the models and methods are demonstrated in the case study.

  9. Latching and Declutching Control of the Solo Duck Wave-Energy Converter with Different Load Types

    Directory of Open Access Journals (Sweden)

    Jinming Wu

    2017-12-01

    Full Text Available The solo duck wave-energy converter (WEC captures power in a point absorber manner, hence it exhibits high power-capture efficiency within only a narrow bandwidth. Passive control is characterized by a unidirectional power flow, and thus its engineering implementation can be simplified. In this paper, two typical passive control strategies, latching and declutching control, are applied to the solo duck WEC to improve its power-capture performance at wave periods larger and smaller than the natural period of the WEC, respectively. Special attention is paid to the peak value of instantaneous WEC performance parameters, including the peak motion excursion, the peak power take-off (PTO moment, and the peak-to-average power ratio, when the captured power is maximized. Performance differences between the linear and coulomb loads are also investigated. Results show that both latching and declutching control can effectively improve captured power, but also incidentally increase the peak motion excursion and peak-to-average power ratio. When under latching and declutching control, the coulomb load leads to the same maximum relative capture width and peak motion excursion as the linear load, but presents smaller peak PTO moment and peak-to-average power ratio than the linear load, hence making the coulomb load the better choice for the solo duck WEC.

  10. Developing strategies to enhance loading efficiency of erythrosensors

    Science.gov (United States)

    Bustamante Lopez, Sandra C.; Ritter, Sarah C.; Meissner, Kenith E.

    2014-02-01

    For diabetics, continuous glucose monitoring and the resulting tighter control of glucose levels ameliorate serious complications from hypoglycemia and hyperglycemia. Diabetics measure their blood glucose levels multiple times a day by finger pricks, or use implantable monitoring devices. Still, glucose and other analytes in the blood fluctuate throughout the day and the current monitoring methods are invasive, immunogenic, and/or present biodegradation problems. Using carrier erythrocytes loaded with a fluorescent sensor, we seek to develop a biodegradable, efficient, and potentially cost effective method to continuously sense blood analytes. We aim to reintroduce sensor-loaded erythrocytes to the bloodstream and conserve the erythrocytes lifetime of 120 days in the circulatory system. Here, we compare the efficiency of two loading techniques: hypotonic dilution and electroporation. Hypotonic dilution employs hypotonic buffer to create transient pores in the erythrocyte membrane, allowing dye entrance and a hypertonic buffer to restore tonicity. Electroporation relies on controlled electrical pulses that results in reversible pores formation to allow cargo entrance, follow by incubation at 37°C to reseal. As part of the cellular characterization of loaded erythrocytes, we focus on cell size, shape, and hemoglobin content. Cell recovery, loading efficiency and cargo release measurements render optimal loading conditions. The detected fluorescent signal from sensor-loaded erythrocytes can be translated into a direct measurement of analyte levels in the blood stream. The development of a suitable protocol to engineer carrier erythrocytes has profound and lasting implications in the erythrosensor's lifespan and sensing capabilities.

  11. Robust Frequency and Voltage Stability Control Strategy for Standalone AC/DC Hybrid Microgrid

    Directory of Open Access Journals (Sweden)

    Furqan Asghar

    2017-05-01

    Full Text Available The microgrid (MG concept is attracting considerable attention as a solution to energy deficiencies, especially in remote areas, but the intermittent nature of renewable sources and varying loads cause many control problems and thereby affect the quality of power within a microgrid operating in standalone mode. This might cause large frequency and voltage deviations in the system due to unpredictable output power fluctuations. Furthermore, without any main grid support, it is more complex to control and manage the system. In past, droop control and various other coordination control strategies have been presented to stabilize the microgrid frequency and voltages, but in order to utilize the available resources up to their maximum capacity in a positive way, new and robust control mechanisms are required. In this paper, a standalone microgrid is presented, which integrates renewable energy-based distributed generations and local loads. A fuzzy logic-based intelligent control technique is proposed to maintain the frequency and DC (direct current-link voltage stability for sudden changes in load or generation power. Also from a frequency control perspective, a battery energy storage system (BESS is suggested as a replacement for a synchronous generator to stabilize the nominal system frequency as a synchronous generator is unable to operate at its maximum efficiency while being controlled for stabilization purposes. Likewise, a super capacitor (SC and BESS is used to stabilize DC bus voltages even though maximum possible energy is being extracted from renewable generated sources using maximum power point tracking. This newly proposed control method proves to be effective by reducing transient time, minimizing the frequency deviations, maintaining voltages even though maximum power point tracking is working and preventing generators from exceeding their power ratings during disturbances. However, due to the BESS limited capacity, load switching

  12. Amelioration of the cooling load based chiller sequencing control

    International Nuclear Information System (INIS)

    Huang, Sen; Zuo, Wangda; Sohn, Michael D.

    2016-01-01

    Highlights: • We developed a new approach for the optimal load distribution for chillers. • We proposed a new approach to optimize the number of operating chillers. • We provided a holistic solution to address chiller sequencing control problems. - Abstract: Cooling Load based Control (CLC) for the chiller sequencing is a commonly used control strategy for multiple-chiller plants. To improve the energy efficiency of these chiller plants, researchers proposed various CLC optimization approaches, which can be divided into two groups: studies to optimize the load distribution and studies to identify the optimal number of operating chillers. However, both groups have their own deficiencies and do not consider the impact of each other. This paper aims to improve the CLC by proposing three new approaches. The first optimizes the load distribution by adjusting the critical points for the chiller staging, which is easier to be implemented than existing approaches. In addition, by considering the impact of the load distribution on the cooling tower energy consumption and the pump energy consumption, this approach can achieve a better energy saving. The second optimizes the number of operating chillers by modulating the critical points and the condenser water set point in order to achieve the minimal energy consumption of the entire chiller plant that may not be guaranteed by existing approaches. The third combines the first two approaches to provide a holistic solution. The proposed three approaches were evaluated via a case study. The results show that the total energy consumption saving for the studied chiller plant is 0.5%, 5.3% and 5.6% by the three approaches, respectively. An energy saving of 4.9–11.8% can be achieved for the chillers at the cost of more energy consumption by the cooling towers (increases of 5.8–43.8%). The pumps’ energy saving varies from −8.6% to 2.0%, depending on the approach.

  13. A review of wind turbine-oriented active flow control strategies

    Science.gov (United States)

    Aubrun, Sandrine; Leroy, Annie; Devinant, Philippe

    2017-10-01

    To reduce the levelized cost of energy, the energy production, robustness and lifespan of horizontal axis wind turbines (HAWTs) have to be improved to ensure optimal energy production and operational availability during periods longer than 15-20 years. HAWTs are subject to unsteady wind loads that generate combinations of unsteady mechanical loads with characteristic time scales from seconds to minutes. This can be reduced by controlling the aerodynamic performance of the wind turbine rotors in real time to compensate the overloads. Mitigating load fluctuations and optimizing the aerodynamic performance at higher time scales need the development of fast-response active flow control (AFC) strategies located as close as possible to the torque generation, i.e., directly on the blades. The most conventional actuators currently used in HAWTs are mechanical flaps/tabs (similar to aeronautical accessories), but some more innovative concepts based on fluidic and plasma actuators are very promising since they are devoid of mechanical parts, have a fast response and can be driven in unsteady modes to influence natural instabilities of the flow. In this context, the present paper aims at giving a state-of-the-art review of current research in wind turbine-oriented flow control strategies applied at the blade scale. It provides an overview of research conducted in the last decade dealing with the actuators and devices devoted to developing AFC on rotor blades, focusing on the flow phenomena that they cause and that can lead to aerodynamic load increase or decrease. After providing some general background on wind turbine blade aerodynamics and on the atmospheric flows in which HAWTs operate, the review focuses on flow separation control and circulation control mainly through experimental investigations. It is followed by a discussion about the overall limitations of current studies in the wind energy context, with a focus on a few studies that attempt to provide a global

  14. The effect of load-controlled bending load on the failure pressure of wall-thinned pipe elbows

    International Nuclear Information System (INIS)

    Kim, Jin Weon; Yoon, Min Soo; Park, Chi Yong

    2013-01-01

    Highlights: • We evaluated bending load effect on the failure pressure of wall-thinned pipe elbows. • Burst tests were conducted on real-scale elbow specimens with local wall thinning. • The tests were performed under combined pressure and load-controlled bending. • Load-controlled bending reduced the failure pressure of wall-thinned elbows. • Bending load effect was significant for opening-mode and intrados wall-thinning case. - Abstract: In this research, burst tests were conducted on real-scale elbow specimens, each with an artificial local wall-thinning defect, under combined internal pressure and constant in-plane bending load, as well as under simple internal pressure, to evaluate the effect of load-controlled bending load on the failure pressure of locally wall-thinned pipe elbows. Ninety-degree, 65A Schedule 80 elbows, with wall-thinning defects in the intrados and extrados, were used as specimens. The bending loads were in-plane opening- and closing-mode bending, applied in load-control mode. The results clearly indicated that a load-controlled in-plane bending load reduced the failure pressure of wall-thinned pipe elbows, in contrast to observations previously made under displacement-controlled bending conditions. The effect of the bending load was more significant for opening-mode than for closing-mode bending, regardless of the wall-thinning location in the elbow. Also, the effect was greater when the wall-thinning defect was located in the intrados region of the elbow, rather than the extrados region. Existing models that have been proposed to evaluate the failure of wall-thinned elbows under simple internal pressure conservatively predicted the failure pressure of elbows subjected to a combined internal pressure and load-controlled bending load

  15. Interactive Control System, Intended Strategy, Implemented Strategy dan Emergent Strategy

    Directory of Open Access Journals (Sweden)

    Tubagus Ismail

    2012-09-01

    Full Text Available The purpose of this study was to examine the relationship between management control system (MCS and strategy formation processes, namely: intended strategy, emergent strategy and impelemented strategy. The focus of MCS in this study was interactive control system. The study was based on Structural Equation Modeling (SEM as its multivariate analyses instrument. The samples were upper middle managers of manufacturing company in Banten Province, DKI Jakarta Province and West Java Province. AMOS Software 16 program is used as an additional instrument to resolve the problem in SEM modeling. The study found that interactive control system brought a positive and significant influence on Intended strategy; interactive control system brought a positive and significant influence on implemented strategy; interactive control system brought a positive and significant influence on emergent strategy. The limitation of this study is that our empirical model only used one way relationship between the process of strategy formation and interactive control system.

  16. Central FPGA-based Destination and Load Control in the LHCb MHz Event Readout

    CERN Document Server

    Jacobsson, Richard

    2012-01-01

    The readout strategy of the LHCb experiment [1] is based on complete event readout at 1 MHz [2]. Over 300 sub-detector readout boards transmit event fragments at 1 MHz over a commercial 70 Gigabyte/s switching network to a distributed event building and trigger processing farm with 1470 individual multi-core computer nodes [3]. In the original specifications, the readout was based on a pure push protocol. This paper describes the proposal, implementation, and experience of a powerful non-conventional mixture of a push and a pull protocol, akin to credit-based flow control. A high-speed FPGA-based central master module controls the event fragment packing in the readout boards, the assignment of the farm node destination for each event, and controls the farm load based on an asynchronous pull mechanism from each farm node. This dynamic readout scheme relies on generic event requests and the concept of node credit allowing load balancing and trigger rate regulation as a function of the global farm load. It also ...

  17. Demand Response Load Following of Source and Load Systems

    DEFF Research Database (Denmark)

    Hu, Jianqiang; Cao, Jinde; Yong, Taiyou

    2017-01-01

    This paper presents a demand response load following strategy for an interconnected source and load system, in which we utilize traditional units and population of cooling thermostatically controlled loads (TCLs) to follow the mismatched power caused by the load activities and the renewable power...... injection in real time. In the demand side of power systems, these TCLs are often affiliated to a bus load agent and can be aggregated to multiple TCL aggregators. Firstly, aggregate evaluation of the TCL aggregator is carried out based on a bilinear aggregate model so as to derive the available regulation...

  18. Energy evaluation of optimal control strategies for central VWV chiller systems

    International Nuclear Information System (INIS)

    Jin Xinqiao; Du Zhimin; Xiao Xiaokun

    2007-01-01

    Under various conditions, the actual load of the heating, ventilation and air conditioning (HVAC) systems is less than it is originally designed in most operation periods. To save energy and to optimize the controls for chilling systems, the performance of variable water volume (VWV) systems and characteristics of control systems are analyzed, and three strategies are presented and tested based on simulation in this paper. Energy evaluation for the three strategies shows that they can save energy to some extent, and there is potential remained. To minimize the energy consumption of chilling system, the setpoints of controls of supply chilled water temperature and supply head of secondary pump should be optimized simultaneously

  19. Robust nonlinear model predictive control for nuclear power plants in load following operations with bounded xenon oscillations

    International Nuclear Information System (INIS)

    Eliasi, H.; Menhaj, M.B.; Davilu, H.

    2011-01-01

    Research highlights: → In this work, a robust nonlinear model predictive control algorithm is developed. → This algorithm is applied to control the power level for load following. → The state constraints are imposed on the predicted trajectory during optimization. → The xenon oscillations are the main constraint for the load following problem. → In this algorithm, xenon oscillations are bounded within acceptable limits. - Abstract: One of the important operations in nuclear power plants is load-following in which imbalance of axial power distribution induces xenon oscillations. These oscillations must be maintained within acceptable limits otherwise the nuclear power plant could become unstable. Therefore, bounded xenon oscillation considered to be a constraint for the load-following operation. In this paper, a robust nonlinear model predictive control for the load-following operation problem is proposed that ensures xenon oscillations are kept bounded within acceptable limits. The proposed controller uses constant axial offset (AO) strategy to maintain xenon oscillations to be bounded. The constant AO is a robust state constraint for load-following problem. The controller imposes restricted state constraints on the predicted trajectory during optimization which guarantees robust satisfaction of state constraints without restoring to a min-max optimization problem. Simulation results show that the proposed controller for the load-following operation is so effective so that the xenon oscillations kept bounded in the given region.

  20. Hydrophobic Drug-Loaded PEGylated Magnetic Liposomes for Drug-Controlled Release

    Science.gov (United States)

    Hardiansyah, Andri; Yang, Ming-Chien; Liu, Ting-Yu; Kuo, Chih-Yu; Huang, Li-Ying; Chan, Tzu-Yi

    2017-05-01

    Less targeted and limited solubility of hydrophobic-based drug are one of the serious obstacles in drug delivery system. Thus, new strategies to enhance the solubility of hydrophobic drug and controlled release behaviors would be developed. Herein, curcumin, a model of hydrophobic drug, has been loaded into PEGylated magnetic liposomes as a drug carrier platform for drug controlled release system. Inductive magnetic heating (hyperthermia)-stimulated drug release, in vitro cellular cytotoxicity assay of curcumin-loaded PEGylated magnetic liposomes and cellular internalization-induced by magnetic guidance would be investigated. The resultant of drug carriers could disperse homogeneously in aqueous solution, showing a superparamagnetic characteristic and could inductive magnetic heating with external high-frequency magnetic field (HFMF). In vitro curcumin release studies confirmed that the drug carriers exhibited no significant release at 37 °C, whereas exhibited rapid releasing at 45 °C. However, it would display enormous (three times higher) curcumin releasing under the HFMF exposure, compared with that without HFMF exposure at 45 °C. In vitro cytotoxicity test shows that curcumin-loaded PEGylated magnetic liposomes could efficiently kill MCF-7 cells in parallel with increasing curcumin concentration. Fluorescence microscopy observed that these drug carriers could internalize efficiently into the cellular compartment of MCF-7 cells. Thus, it would be anticipated that the novel hydrophobic drug-loaded PEGylated magnetic liposomes in combination with inductive magnetic heating are promising to apply in the combination of chemotherapy and thermotherapy for cancer therapy.

  1. Power Stabilization Strategy of Random Access Loads in Electric Vehicles Wireless Charging System at Traffic Lights

    Directory of Open Access Journals (Sweden)

    Linlin Tan

    2016-10-01

    Full Text Available An opportunity wireless charging system for electric vehicles when they stop and wait at traffic lights is proposed in this paper. In order to solve the serious power fluctuation caused by random access loads, this study presents a power stabilization strategy based on counting the number of electric vehicles in a designated area, including counting method, power source voltage adjustment strategy and choice of counting points. Firstly, the circuit model of a wireless power system with multi-loads is built and the equation of each load is obtained. Secondly, after the counting method of electric vehicles is stated, the voltage adjustment strategy, based on the number of electric vehicles when the system is at a steady state, is set out. Then, the counting points are chosen according to power curves when the voltage adjustment strategy is adopted. Finally, an experimental prototype is implemented to verify the power stabilization strategy. The experimental results show that, with the application of this strategy, the charging power is stabilized with the fluctuation of no more than 5% when loads access randomly.

  2. NWTC Researchers Field-Test Advanced Control Turbine Systems to Increase Performance, Decrease Structural Loading of Wind Turbines and Plants

    Energy Technology Data Exchange (ETDEWEB)

    2015-08-01

    Researchers at the National Renewable Energy Laboratory's (NREL's) National Wind Technology Center (NWTC) are studying component controls, including new advanced actuators and sensors, for both conventional turbines as well as wind plants. This research will help develop innovative control strategies that reduce aerodynamic structural loads and improve performance. Structural loads can cause damage that increase maintenance costs and shorten the life of a turbine or wind plant.

  3. Neural Network Based Load Frequency Control for Restructuring ...

    African Journals Online (AJOL)

    Neural Network Based Load Frequency Control for Restructuring Power Industry. ... an artificial neural network (ANN) application of load frequency control (LFC) of a Multi-Area power system by using a neural network controller is presented.

  4. Balancing Power Output and Structural Fatigue of Wave Energy Converters by Means of Control Strategies

    Directory of Open Access Journals (Sweden)

    Francesco Ferri

    2014-04-01

    Full Text Available In order to reduce the cost of electricity produced by wave energy converters (WECs, the benefit of selling electricity as well as the investment costs of the structure has to be considered. This paper presents a methodology for assessing the control strategy for a WEC with respect to both energy output and structural fatigue loads. Different active and passive control strategies are implemented (proportional (P controller, proportional-integral (PI controller, proportional-integral-derivative with memory compensation (PID controller, model predictive control (MPC and maximum energy controller (MEC, and load time-series resulting from numerical simulations are used to design structural parts based on fatigue analysis using rain-flow counting, Stress-Number (SN curves and Miner’s rule. The objective of the methodology is to obtain a cost-effective WEC with a more comprehensive analysis of a WEC based on a combination of well known control strategies and standardised fatigue methods. The presented method is then applied to a particular case study, the Wavestar WEC, for a specific location in the North Sea. Results, which are based on numerical simulations, show the importance of balancing the gained power against structural fatigue. Based on a simple cost model, the PI controller is shown as a viable solution.

  5. Load Reduction, Demand Response and Energy Efficient Technologies and Strategies

    Energy Technology Data Exchange (ETDEWEB)

    Boyd, Paul A.; Parker, Graham B.; Hatley, Darrel D.

    2008-11-19

    The Department of Energy’s (DOE’s) Pacific Northwest National Laboratory (PNNL) was tasked by the DOE Office of Electricity (OE) to recommend load reduction and grid integration strategies, and identify additional demand response (energy efficiency/conservation opportunities) and strategies at the Forest City Housing (FCH) redevelopment at Pearl Harbor and the Marine Corps Base Hawaii (MCBH) at Kaneohe Bay. The goal was to provide FCH staff a path forward to manage their electricity load and thus reduce costs at these FCH family housing developments. The initial focus of the work was at the MCBH given the MCBH has a demand-ratchet tariff, relatively high demand (~18 MW) and a commensurate high blended electricity rate (26 cents/kWh). The peak demand for MCBH occurs in July-August. And, on average, family housing at MCBH contributes ~36% to the MCBH total energy consumption. Thus, a significant load reduction in family housing can have a considerable impact on the overall site load. Based on a site visit to the MCBH and meetings with MCBH installation, FCH, and Hawaiian Electric Company (HECO) staff, recommended actions (including a "smart grid" recommendation) that can be undertaken by FCH to manage and reduce peak-demand in family housing are made. Recommendations are also made to reduce overall energy consumption, and thus reduce demand in FCH family housing.

  6. Control Strategy Based on Wavelet Transform and Neural Network for Hybrid Power System

    Directory of Open Access Journals (Sweden)

    Y. D. Song

    2013-01-01

    Full Text Available This paper deals with an energy management of a hybrid power generation system. The proposed control strategy for the energy management is based on the combination of wavelet transform and neural network arithmetic. The hybrid system in this paper consists of an emulated wind turbine generator, PV panels, DC and AC loads, lithium ion battery, and super capacitor, which are all connected on a DC bus with unified DC voltage. The control strategy is responsible for compensating the difference between the generated power from the wind and solar generators and the demanded power by the loads. Wavelet transform decomposes the power difference into smoothed component and fast fluctuated component. In consideration of battery protection, the neural network is introduced to calculate the reference power of battery. Super capacitor (SC is controlled to regulate the DC bus voltage. The model of the hybrid system is developed in detail under Matlab/Simulink software environment.

  7. Fast core prediction simulator for load follow control

    International Nuclear Information System (INIS)

    Yim, Man Sung; Lee, Sang Hoon; Lee, Un Chul

    1990-01-01

    An operator-assisting system for the reactor core control under power changing operating condition was developed. The system is consisted of core simulator routine and Xenon and Iodine initial condition generation routine. The initial condition generation routine, without exactly knowing the core status, is capable of providing accurate number densities and axial offset conditions of Xenon and Iodine after several hours of predictor- corrector calculations using the plant instrumentation signals of power level and power axial offset. The core simulator routine, even with the two node core model, gives equivalently accurate results as the one-dimensional model for the core behaviour simulation under power changing condition and can provide proper control strategies for load follow operation. The core simulator can also be used by the operator to develop remedial actions to restore the distorted power distribution by using its prediction capability

  8. Optimal Control Allocation with Load Sensor Feedback for Active Load Suppression, Experiment Development

    Science.gov (United States)

    Miller, Christopher J.; Goodrick, Dan

    2017-01-01

    The problem of control command and maneuver induced structural loads is an important aspect of any control system design. The aircraft structure and the control architecture must be designed to achieve desired piloted control responses while limiting the imparted structural loads. The classical approach is to utilize high structural margins, restrict control surface commands to a limited set of analyzed combinations, and train pilots to follow procedural maneuvering limitations. With recent advances in structural sensing and the continued desire to improve safety and vehicle fuel efficiency, it is both possible and desirable to develop control architectures that enable lighter vehicle weights while maintaining and improving protection against structural damage. An optimal control technique has been explored and shown to achieve desirable vehicle control performance while limiting sensed structural loads. The subject of this paper is the design of the optimal control architecture, and provides the reader with some techniques for tailoring the architecture, along with detailed simulation results.

  9. Control strategies for crane systems: A comprehensive review

    Science.gov (United States)

    Ramli, Liyana; Mohamed, Z.; Abdullahi, Auwalu M.; Jaafar, H. I.; Lazim, Izzuddin M.

    2017-10-01

    Crane systems are tremendously utilised in numerous heavy load transportation industries, and therefore, the control of crane systems is a well-established research field. As the last review paper was published more than a decade ago, there is a lack of collected and organised information regarding the latest and the newest updates on control strategies for crane control systems. Hence, this paper presents a comprehensive review of crane control strategies discussing the latest research works during the years from 2000 to 2016. Various crane types and control issues are highlighted, followed by the main focus of this paper, an extensive review of the control schemes for diverse types of crane systems that have been carried out in the 21st century. A brief review on modelling of single-pendulum and double-pendulum crane systems is also given. In addition, anti-sway control systems for industrial cranes that are available on the market is described. This paper summarises most of the related work and also pays a special focus on research trends regarding the control of crane systems that have been previously published in the literature. It is envisaged that this review paper will be helpful to new researchers when identifying research directions for this particular area of interest.

  10. Research of Control Strategy in the Large Electric Cylinder Position Servo System

    Directory of Open Access Journals (Sweden)

    Yongguang Liu

    2015-01-01

    Full Text Available An ideal positioning response is very difficult to realize in the large electric cylinder system that is applied in missile launcher because of the presence of many nonlinear factors such as load disturbance, parameter variations, lost motion, and friction. This paper presents a piecewise control strategy based on the optimized positioning principle. The combined application of position interpolation method and modified incremental PID with dead band is proposed and applied into control system. The experimental result confirms that this combined control strategy is not only simple to be applied into high accuracy real-time control system but also significantly improves dynamic response, steady accuracy, and anti-interference performance, which has very important significance to improve the smooth control of the large electric cylinder.

  11. Load Control System Reliability

    Energy Technology Data Exchange (ETDEWEB)

    Trudnowski, Daniel [Montana Tech of the Univ. of Montana, Butte, MT (United States)

    2015-04-03

    This report summarizes the results of the Load Control System Reliability project (DOE Award DE-FC26-06NT42750). The original grant was awarded to Montana Tech April 2006. Follow-on DOE awards and expansions to the project scope occurred August 2007, January 2009, April 2011, and April 2013. In addition to the DOE monies, the project also consisted of matching funds from the states of Montana and Wyoming. Project participants included Montana Tech; the University of Wyoming; Montana State University; NorthWestern Energy, Inc., and MSE. Research focused on two areas: real-time power-system load control methodologies; and, power-system measurement-based stability-assessment operation and control tools. The majority of effort was focused on area 2. Results from the research includes: development of fundamental power-system dynamic concepts, control schemes, and signal-processing algorithms; many papers (including two prize papers) in leading journals and conferences and leadership of IEEE activities; one patent; participation in major actual-system testing in the western North American power system; prototype power-system operation and control software installed and tested at three major North American control centers; and, the incubation of a new commercial-grade operation and control software tool. Work under this grant certainly supported the DOE-OE goals in the area of “Real Time Grid Reliability Management.”

  12. A new strategy of axial power distribution control based on three axial offsets concept

    International Nuclear Information System (INIS)

    Shimazu, Yoichiro

    2009-01-01

    We have proposed a very simple control procedure for axial xenon oscillation control based on a characteristic trajectory. The trajectory is drawn by three offsets of power distributions, namely, AOp, AOi and AOx. They are defined as the offset of axial power distribution, the offset of the power distribution under which the current iodine distribution is obtained as the equilibrium and that for xenon distribution, respectively. When these offsets are plotted on X-Y plane for (AOp-AOx, AOi-AOx) the trajectory draws a quite characteristic ellipse (or an elliptic spiral). On the other hands, Constant Axial Offset Control (CAOC) procedure is adopted as axial power distribution control strategy during both base load and load following operations in domestic PWRs. In the previous paper, we have presented an innovative procedure of axial power distribution control during load following in PWRs based on this trajectory such that the AOp-AOx is to be controlled to zero when the value deviates the pre-determined limiting values. In this paper we propose a modified control strategy to get more stability of axial power distributions. In this strategy, we control the trajectory to be close to the major axis of the ellipse when the power distribution reaches the limiting values. In other words, the plot is not controlled only to reduce AOp-AOx but also AOi-AOx is taken into account at the same time. It is known that when the plot is controlled to the major axis, it means that the point gives the peak position of axial xenon oscillation. Therefore xenon oscillation will not increase its amplitude any more. Thus more stable axial power distribution control is attained. This kind of design concept is quite important especially for the future PWRs with elongated fuel length and longer core life. Because in a longer effective core and also the longer core life, it has been known that the stability of axial xenon oscillation becomes more unstable. In this paper, some simulation

  13. Vestibular control of standing balance is enhanced with increased cognitive load.

    Science.gov (United States)

    McGeehan, Michael A; Woollacott, Marjorie H; Dalton, Brian H

    2017-04-01

    When cognitive load is elevated during a motor task, cortical inhibition and reaction time are increased; yet, standing balance control is often unchanged. This disconnect is likely explained by compensatory mechanisms within the balance system such as increased sensitivity of the vestibulomotor pathway. This study aimed to determine the effects of increased cognitive load on the vestibular control of standing balance. Participants stood blindfolded on a force plate with their head facing left and arms relaxed at their sides for two trials while exposed to continuous electrical vestibular stimulation (EVS). Participants either stood quietly or executed a cognitive task (double-digit arithmetic). Surface electromyography (EMG) and anterior-posterior ground-body forces (APF) were measured in order to evaluate vestibular-evoked balance responses in the frequency (coherence and gain) and time (cumulant density) domains. Total distance traveled for anterior-posterior center of pressure (COP) was assessed as a metric of balance variability. Despite similar distances traveled for COP, EVS-medial gastrocnemius (MG) EMG and EVS-APF coherence and EVS-TA EMG and EVS-MG EMG gain were elevated for multiple frequencies when standing with increased cognitive load. For the time domain, medium-latency peak amplitudes increased by 13-54% for EVS-APF and EVS-EMG relationships with the cognitive task compared to without. Peak short-latency amplitudes were unchanged. These results indicate that reliance on vestibular control of balance is enhanced when cognitive load is elevated. This augmented neural strategy may act to supplement divided cortical processing resources within the balance system and compensate for the acute neuromuscular modifications associated with increased cognitive demand.

  14. Use and optimization of a dual-flowrate loading strategy to maximize throughput in protein-a affinity chromatography.

    Science.gov (United States)

    Ghose, Sanchayita; Nagrath, Deepak; Hubbard, Brian; Brooks, Clayton; Cramer, Steven M

    2004-01-01

    The effect of an alternate strategy employing two different flowrates during loading was explored as a means of increasing system productivity in Protein-A chromatography. The effect of such a loading strategy was evaluated using a chromatographic model that was able to accurately predict experimental breakthrough curves for this Protein-A system. A gradient-based optimization routine is carried out to establish the optimal loading conditions (initial and final flowrates and switching time). The two-step loading strategy (using a higher flowrate during the initial stages followed by a lower flowrate) was evaluated for an Fc-fusion protein and was found to result in significant improvements in process throughput. In an extension of this optimization routine, dynamic loading capacity and productivity were simultaneously optimized using a weighted objective function, and this result was compared to that obtained with the single flowrate. Again, the dual-flowrate strategy was found to be superior.

  15. Real-time integration of control strategies for an isolated DFIG-based WECS

    Science.gov (United States)

    Bouchiba, Nouha; Barkia, Asma; Chrifi-Alaoui, Larbi; Drid, Saïd; Sallem, Souhir; Kammoun, M. B. A.

    2017-08-01

    This paper deals with voltage and frequency control of a stand-alone wind energy conversion system (WECS) based on a double fed induction generator (DFIG) under wind speed and load variations. In this context, two kinds of linear and nonlinear control strategies, classical PI and backstepping, have been applied to the system in real time. A series of experiments have been conducted to evaluate and to compare dynamic performances of the proposed control approaches. Experiments on a 1.5Kw doubly fed induction machine in real time are carried out using dSpace DS1104 card based on the MATLAB/Simulink environment. Experimental results show the validity of implemented controllers and demonstrate the effectiveness, the precision and the rapidity of the backstepping control strategy compared with the PI controller.

  16. An Elastic Charging Service Fee-Based Load Guiding Strategy for Fast Charging Stations

    Directory of Open Access Journals (Sweden)

    Shu Su

    2017-05-01

    Full Text Available Compared with the traditional slow charging loads, random integration of large scale fast charging loads will exert more serious impacts on the security of power network operation. Besides, to maximize social benefits, effective scheduling strategies guiding fast charging behaviors should be formulated rather than simply increasing infrastructure construction investments on the power grid. This paper first analyzes the charging users’ various responses to an elastic charging service fee, and introduces the index of charging balance degree to a target region by considering the influence of fast charging loads on the power grid. Then, a multi-objective optimization model of the fast charging service fee is constructed, whose service fee can be further optimized by employing a fuzzy programming method. Therefore, both users’ satisfaction degree and the equilibrium of charging loads can be maintained simultaneously by reasonably guiding electric vehicles (EVs to different fast charging stations. The simulation results demonstrate the effectiveness of the proposed dynamic charging service pricing and the corresponding fast charging load guidance strategy.

  17. Application of Model Predictive Control for Active Load Management in a Distributed Power System with High Wind Penetration

    DEFF Research Database (Denmark)

    Zong, Yi; Kullmann, Daniel; Thavlov, Anders

    2012-01-01

    management. It also presents in detail how to implement a thermal model predictive controller (MPC) for the heaters' power consumption prediction in the PowerFlexHouse. It demonstrates that this MPC strategy can realize load shifting, and using good predictions in MPC-based control, a better matching...

  18. Wavelet neural network load frequency controller

    International Nuclear Information System (INIS)

    Hemeida, Ashraf Mohamed

    2005-01-01

    This paper presents the feasibility of applying a wavelet neural network (WNN) approach for the load frequency controller (LFC) to damp the frequency oscillations of two area power systems due to load disturbances. The present intelligent control system trained the wavelet neural network (WNN) controller on line with adaptive learning rates, which are derived in the sense of a discrete type Lyapunov stability theorem. The present WNN controller is designed individually for each area. The proposed technique is applied successfully for a wide range of operating conditions. The time simulation results indicate its superiority and effectiveness over the conventional approach. The effects of consideration of the governor dead zone on the system performance are studied using the proposed controller and the conventional one

  19. A Control Strategy for Flywheel Energy Storage System for Frequency Stability Improvement in Islanded Microgrid

    Directory of Open Access Journals (Sweden)

    A. A. Khodadoost Arani

    2017-03-01

    Full Text Available The Micro-Grid (MG stability is a significant issue that must be maintained in all operational modes. Usually, two control strategies can be applied to MG; V/f control and PQ control strategies. MGs with V/f control strategy should have some Distributed Generators (DGs which have fast responses versus load changes. The Flywheel Energy Storage System (FESS has this characteristic. The FESS, which converts the mechanical energy to electrical form, can generate electrical power or absorb the additional power in power systems or MGs. In this paper, the FESS structure modeled in detail and two control strategies (V/f and PQ control are applied for this application. In addition, in order to improve the MG frequency and voltage stability, two complementary controllers are proposed for the V/f control strategy; conventional PI and Fuzzy Controllers. A typical low voltage network, including FESS is simulated for four distinct scenarios in the MATLAB/ Simulink environment. It is shown that fuzzy controller has better performance than conventional PI controller in islanded microgrid.

  20. Incorporation of β-actin loading control into zymography.

    Science.gov (United States)

    Govindasamy, Natasha; Yan, MengJie; Jurasz, Paul

    2016-11-01

    Gelatin zymography and immunoblot are widely used gel electrophoresis techniques to study matrix metalloproteinases-2 and -9. Each method has its advantages and disadvantages. Zymography is exquisitely sensitive but offers no loading control to ensure equal sample loading. Immunoblot is a 100-1000-fold less sensitive, but allows for the probing of a sample loading control such as β-actin to ensure accurate protein loading. In this report, we describe two simple protocols that combine gelatin zymography to study MMP-2 and -9 levels with an in-gel β-actin immunoblot loading control, thus combining sensitivity and accuracy in a single assay. The protocols incorporate the loading of molecular weight markers to demarcate MMP-2/-9 from the β-actin. The first protocol utilizes the overlay of a 10% zymography gel over a 5% Tris-Glycine separating gel from which the β-actin is transferred. The second protocol involves the direct transfer of the β-actin from a single 10% zymography gel.

  1. Start-up of intensive anaerobic wastewater methanization processes: impact of hydrodynamic conditions and of control strategy of organic load increase on biofilm formation and activity

    International Nuclear Information System (INIS)

    Cresson, Romain

    2006-01-01

    This research thesis aims at being a contribution to the understanding of mechanisms of anaerobic film development and maturation, in order to obtain a better control of their formation and this to decrease the duration of the bioreactor start-up phase. More precisely, the author analysed the impact of hydrodynamic parameters and of load rise strategy on biofilm characteristics (thickness, density, biodiversity) and on its activity (anaerobic breathing, decontamination kinetics) during its development. Thus, after a recall of the anaerobic digestion principle, the author presents processes, methods and techniques used during this research, reports and discusses the obtained results

  2. A Review of Microgrid Architectures and Control Strategy

    Science.gov (United States)

    Jadav, Krishnarajsinh A.; Karkar, Hitesh M.; Trivedi, I. N.

    2017-12-01

    In this paper microgrid architecture and various converters control strategies are reviewed. Microgrid is defined as interconnected network of distributed energy resources, loads and energy storage systems. This emerging concept realizes the potential of distributed generators. AC microgrid interconnects various AC distributed generators like wind turbine and DC distributed generators like PV, fuel cell using inverter. While in DC microgrid output of an AC distributed generator must be converted to DC using rectifiers and DC distributed generator can be directly interconnected. Hybrid microgrid is the solution to avoid this multiple reverse conversions AC-DC-AC and DC-AC-DC that occur in the individual AC-DC microgrid. In hybrid microgrid all AC distributed generators will be connected in AC microgrid and DC distributed generators will be connected in DC microgrid. Interlinking converter is used for power balance in both microgrids, which transfer power from one microgrid to other if any microgrid is overloaded. At the end, review of interlinking converter control strategies is presented.

  3. Adaptive Control System for Autonomous Helicopter Slung Load Operations

    DEFF Research Database (Denmark)

    Bisgaard, Morten; la Cour-Harbo, Anders; Bendtsen, Jan Dimon

    2010-01-01

    system on the helicopter that measures the position of the slung load. The controller is a combined feedforward and feedback scheme for simultaneous avoidance of swing excitation and active swing damping. Simulations and laboratory flight tests show the effectiveness of the combined control system......This paper presents design and verification of an estimation and control system for a helicopter slung load system. The estimator provides position and velocity estimates of the slung load and is designed to augment existing navigation in autonomous helicopters. Sensor input is provided by a vision......, yielding significant load swing reduction compared to the baseline controller....

  4. Sensor comparison study for load alleviating wind turbine pitch control

    DEFF Research Database (Denmark)

    Kragh, Knud Abildgaard; Hansen, Morten Hartvig; Henriksen, Lars Christian

    2014-01-01

    As the size of wind turbines increases, the load alleviating capabilities of the turbine controller are becoming increasingly important. Load alleviating control schemes have traditionally been based on feedback from load sensor; however, recent developments of measurement technologies have enabled...... control on the basis of preview measurements of the inflow acquired using, e.g., light detection and ranging. The potential of alleviating load variations that are caused by mean wind speed changes through feed-forward control have been demonstrated through both experiments and simulations in several...... studies, whereas the potential of preview control for alleviating the load variations caused by azimuth dependent inflow variations is less described. Individual or cyclic pitch is required to alleviate azimuth dependent load variations and is traditionally applied through feedback control of the blade...

  5. Synthetic jet actuation for load control

    NARCIS (Netherlands)

    de Vries, Hein; van der Weide, Edwin Theodorus Antonius; Hoeijmakers, Hendrik Willem Marie

    2014-01-01

    The reduction of wind turbine blade loads is an important issue in the reduction of the costs of energy production. Reduction of the loads of a non-cyclic nature requires so-called smart rotor control, which involves the application of distributed actuators and sensors to provide fast and local

  6. Active load reduction using individual pitch, based on local blade flow measurements

    DEFF Research Database (Denmark)

    Larsen, Torben J.; Aagaard Madsen, H.; Thomsen, K.

    2005-01-01

    -of-the-art load-reducing concepts. Since the new flow-based concept deviates significantly from previous published load-reducing strategies, a comparison of the performance based on aeroelastic simulations is included. Advantages and drawbacks of the systems are discussed. Copyright (C) 2004 John Wiley Sons, Ltd.......A new load-reducing control strategy for individual blade control of large pitch-controlled wind turbines is presented This control concept is based on local blade inflow measurements and offers the possibility of larger load reductions, without loss of power production, than seen in other state...

  7. Above and below boiling thermal loading strategies for large waste packages

    International Nuclear Information System (INIS)

    Smith, M.L.

    1994-01-01

    A simplified repository thermal model was developed with the Mathcad computer code which indicates that large waste packages may be compatible with both above and below boiling repository thermal loading strategies. Minimum spent fuel decay time of at least 20 to 30 years was shown to be important for both thermal loading strategies. Constant isothermal boundary conditions are assumed at the ground surface (296 K) and 305 meters below the water table (309.7 K) with a uniform temperature change of 1.55 10 -2 K/meter. Homogeneous tuff properties are assumed: conductivity (2.1 watt/m-k); density (2.22 gm/cm 3 ); and thermal capacitance (2.17 joule/cm 3 K). Based on these properties, the tuff thermal diffusion coefficient is 9.68 x 10 -7 m 2 /sec

  8. Design of Vickers Hardness Loading Controller

    Directory of Open Access Journals (Sweden)

    Sihai Zhao

    2014-09-01

    Full Text Available Traditionally Vickers testing needs manual works, as a result, it will induce low precision and automatization. So this paper design a new type of loading controlling system, it is based on single chip computer 89S52, used PZT as the force generator in micro Vickers hardness testing. It primarily includes the designing of hardware, software of collecting data and PZT signals by AD667. This article has given the sketch of electrical circuit and controlling software, it also offers the experiment data. The experiments have showed that using this system can exactly control the loading results, and the average tolerance is less than 0.43 %.

  9. Design and Modelling of Thermostatically Controlled Loads as Frequency Controlled Reserve

    DEFF Research Database (Denmark)

    Xu, Zhao; Østergaard, Jacob; Togeby, Mikael

    2007-01-01

    Using demand as frequency controlled reserve (DFR) is beneficial to power systems in many aspects. To study the impacts of this technology on power system operation, control logics and simulation models of relevant loads should be carefully developed. Two advanced control logics for using demand...... frequency, is developed. The developed simulation model is able to represent a variety of aggregated thermostatically controlled loads, such as heaters or refrigerators. Uncertainties including customer behaviours and ambient temperature variation are also modelled. Preliminary simulation results...

  10. Design and Evaluation of Autonomous Hybrid Frequency-Voltage Sensitive Load Controller

    DEFF Research Database (Denmark)

    Douglass, Philip James; Garcia-Valle, Rodrigo; Sossan, Fabrizio

    2013-01-01

    The paper introduces an algorithm for control of autonomous loads without digital communication interfaces to provide both frequency regulation and voltage regulation services. This hybrid controller can be used to enhance frequency sensitive loads to mitigate line overload arising from reduced l...... load diversity. Numerical simulations of the hybrid controller in a representative distribution system show the peak system load was reduced by 12% compared to a purely frequency sensitive load controller.......The paper introduces an algorithm for control of autonomous loads without digital communication interfaces to provide both frequency regulation and voltage regulation services. This hybrid controller can be used to enhance frequency sensitive loads to mitigate line overload arising from reduced...

  11. Modeling nitrate-nitrogen load reduction strategies for the Des Moines River, Iowa using SWAT.

    Science.gov (United States)

    Schilling, Keith E; Wolter, Calvin F

    2009-10-01

    The Des Moines River that drains a watershed of 16,175 km(2) in portions of Iowa and Minnesota is impaired for nitrate-nitrogen (nitrate) due to concentrations that exceed regulatory limits for public water supplies. The Soil Water Assessment Tool (SWAT) model was used to model streamflow and nitrate loads and evaluate a suite of basin-wide changes and targeting configurations to potentially reduce nitrate loads in the river. The SWAT model comprised 173 subbasins and 2,516 hydrologic response units and included point and nonpoint nitrogen sources. The model was calibrated for an 11-year period and three basin-wide and four targeting strategies were evaluated. Results indicated that nonpoint sources accounted for 95% of the total nitrate export. Reduction in fertilizer applications from 170 to 50 kg/ha achieved the 38% reduction in nitrate loads, exceeding the 34% reduction required. In terms of targeting, the most efficient load reductions occurred when fertilizer applications were reduced in subbasins nearest the watershed outlet. The greatest load reduction for the area of land treated was associated with reducing loads from 55 subbasins with the highest nitrate loads, achieving a 14% reduction in nitrate loads achieved by reducing applications on 30% of the land area. SWAT model results provide much needed guidance on how to begin implementing load reduction strategies most efficiently in the Des Moines River watershed.

  12. Dual motor drive vehicle speed synchronization and coordination control strategy

    Science.gov (United States)

    Huang, Hao; Tu, Qunzhang; Jiang, Chenming; Ma, Limin; Li, Pei; Zhang, Hongxing

    2018-04-01

    Multi-motor driven systems are more and more widely used in the field of electric engineering vehicles, as a result of the road conditions and the variable load of engineering vehicles, makes multi-motors synchronization coordinated control system as a key point of the development of the electric vehicle drive system. This paper based on electrical machinery transmission speed in the process of engineering vehicles headed for coordinated control problem, summarized control strategies at home and abroad in recent years, made analysis and comparison of the characteristics, finally discussed the trend of development of the multi-motor coordination control, provided a reference for synchronized control system research of electric drive engineering vehicles.

  13. Residential CCHP microgrid with load aggregator: Operation mode, pricing strategy, and optimal dispatch

    International Nuclear Information System (INIS)

    Gu, Wei; Lu, Shuai; Wu, Zhi; Zhang, Xuesong; Zhou, Jinhui; Zhao, Bo; Wang, Jun

    2017-01-01

    Highlights: •A bilateral transaction mode for the residential CCHP microgrid is proposed. •An energy pricing strategy for the residential CCHP system is proposed. •A novel integrated demand response for the residential loads is proposed. •Two-stage operation optimization model for the CCHP microgrid is proposed. •Operations of typical days and annual scale of the CCHP microgrid are studied. -- Abstract: As the global energy crisis, environmental pollution, and global warming grow in intensity, increasing attention is being paid to combined cooling, heating, and power (CCHP) systems that realize high-efficiency cascade utilization of energy. This paper proposes a bilateral transaction mechanism between a residential CCHP system and a load aggregator (LA). The variable energy cost of the CCHP system is analyzed, based on which an energy pricing strategy for the CCHP system is proposed. Under this pricing strategy, the electricity price is constant, while the heat/cool price is ladder-shaped and dependent on the relationship between the electrical, heat, and cool loads. For the LA, an integrated demand response program is proposed that combines electricity-load shifting and a flexible heating/cooling supply, in which a thermodynamic model of buildings is used to determine the appropriate range of heating/cooling supply. Subsequently, a two-stage optimal dispatch model is proposed for the energy system that comprises the CCHP system and the LA. Case studies consisting of three scenarios (winter, summer, and excessive seasons) are delivered to demonstrate the effectiveness of the proposed approach, and the performance of the proposed pricing strategy is also evaluated by annual operation simulations.

  14. Dynamic Protective Control Strategy for Distributed Generation System with Fixed-speed Wind Turbines

    Institute of Scientific and Technical Information of China (English)

    2012-01-01

    The characteristics of induction generator based fixed-speed wind turbines (FSWT) are investigated. The impacts of different execution time in protective operations are studied under different fauit duration and various wind velocity situations, e.g. , FSWT stabilities of load shedding in distribution systems. Based on this research, a dynamic protective control strategy for a distributed generation system (DGS) with FSWT is proposed. Finally, simulation results demonstrate the effectiveness of the strategy.

  15. Fractional order PID controller for load frequency control

    International Nuclear Information System (INIS)

    Sondhi, Swati; Hote, Yogesh V.

    2014-01-01

    Highlights: • The manuscript shows the design of FOPID controller for the load frequency control. • Performance of FOPID is given for non-reheated, reheated and hydro turbine. • Performance of FOPID is compared to IMC-PID and reduced order IMC-PID design scheme. • Performance of FOPID is better than the existing techniques. - Abstract: Load frequency control (LFC) plays a very important role in providing quality power both in the case of isolated as well as interconnected power systems. In order to maintain good quality power supply, the LFC should possess robustness toward the parametric uncertainty of the system and good disturbance rejection capability. The fractional order controller has the properties such as, eliminating steady state error, robustness toward plant gain variations and also good disturbance rejection. This makes the fractional order PID (FOPID) controller quite suitable for the LFC. Therefore, in this paper a FOPID is designed for single area LFC for all three types of turbines i.e., non-reheated, reheated and hydro turbines. It is observed that the FOPID controller shows better robustness toward ±50% parametric uncertainty and disturbance rejection capability than the existing techniques. Finally, the optimization of controller parameters and robustness evaluation of the control technique is done on the basis of the integral error criterion

  16. Dependence of loading time on control parameters in a standard vapour—loaded magneto—optical trap

    International Nuclear Information System (INIS)

    Zhang Yi-Chi; Wu Ji-Zhou; Li Yu-Qing; Ma Jie; Wang Li-Rong; Zhao Yan-Ting; Xiao Lian-Tuan; Jia Suo-Tang

    2011-01-01

    Loading time is one of the most important dynamic characteristics of a magneto—optical trap. In this paper, we primarily report on a detailed experimental study of the effects of some magneto—optical trap control parameters on loading time, including the background vacuum pressure, the magnetic field gradient, and the intensities of trapping and repumping lasers. We compare the results with previous theoretical and experimental results, and give qualitative analysis. These experimental investigations offer some useful guidelines to control the loading time of magneto—optical traps. The controllable loading time achieved is helpful to enhance the signal-to-noise ratio of photoassociation spectroscopy, which is remarkably improved from 7 to 28.6. (atomic and molecular physics)

  17. A Communication-Less Distributed Voltage Control Strategy for a Multi-Bus AC Islanded Microgrid

    DEFF Research Database (Denmark)

    Wang, Yanbo; Tan, Yongdong; Chen, Zhe

    2014-01-01

    This paper presents a communication-less distributed voltage control strategy for a multi-bus AC islanded microgrid. First, a Kalman Filter-based network voltage estimator is proposed to obtain voltage responses without communication links in the presence of load disturbances. Then, a voltage...... and reliability is improved for islanded microgrids due to communication-less operation. The simulations and experimental results are presented to validate the proposed distributed voltage control strategy....... optimal controller using MPC (Model Predictive Control) are developed to implement voltage optimal control. The contributions of this paper are demonstrated: (1) The proposed voltage estimator can dynamically obtain network voltage responses just through local voltage and current associated with each DG...

  18. Power control method for load-frequency control operation in BWRs

    International Nuclear Information System (INIS)

    Ie, Shin-ichiroo; Ohgo, Yu-kiharu; Itou, Tetsuo; Shida, Tooichi

    1991-01-01

    The preliminary design of an advanced power control method for fast load-following [load frequency control (LFC)] maneuvers in a boiling water reactor (BWR) is described in this paper. Application of a multivariable control method using an optimal linear quadratic (LQ) regulator theory effectively improves control system performance when system variables have significant interactions such as in BWRs. The control problem, however, demands strict constraints on system variable from the standpoint of plant operation. These constraints require the control system to have a nonlinear property for better improvement. Therefore, the effectiveness of LQ control is limited by these constraints, because it is based on a linear model. A new method is needed to compensate for the nonlinear property. In this study, the authors propose a new method using fuzzy reasoning with LQ control to achieve nonlinear compensation

  19. Research on ISFLA-Based Optimal Control Strategy for the Coordinated Charging of EV Battery Swap Station

    Directory of Open Access Journals (Sweden)

    Xueliang Huang

    2013-01-01

    Full Text Available As an important component of the smart grid, electric vehicles (EVs could be a good measure against energy shortages and environmental pollution. A main way of energy supply to EVs is to swap battery from the swap station. Based on the characteristics of EV battery swap station, the coordinated charging optimal control strategy is investigated to smooth the load fluctuation. Shuffled frog leaping algorithm (SFLA is an optimization method inspired by the memetic evolution of a group of frogs when seeking food. An improved shuffled frog leaping algorithm (ISFLA with the reflecting method to deal with the boundary constraint is proposed to obtain the solution of the optimal control strategy for coordinated charging. Based on the daily load of a certain area, the numerical simulations including the comparison of PSO and ISFLA are carried out and the results show that the presented ISFLA can effectively lower the peak-valley difference and smooth the load profile with the faster convergence rate and higher convergence precision.

  20. Software defined network architecture based research on load balancing strategy

    Science.gov (United States)

    You, Xiaoqian; Wu, Yang

    2018-05-01

    As a new type network architecture, software defined network has the key idea of separating the control place of the network from the transmission plane, to manage and control the network in a concentrated way; in addition, the network interface is opened on the control layer and the data layer, so as to achieve programmable control of the network. Considering that only the single shortest route is taken into the calculation of traditional network data flow transmission, and congestion and resource consumption caused by excessive load of link circuits are ignored, a link circuit load based flow media business QoS gurantee system is proposed in this article to divide the flow in the network into ordinary data flow and QoS flow. In this way, it supervises the link circuit load with the controller so as to calculate reasonable route rapidly and issue the flow table to the exchanger, to finish rapid data transmission. In addition, it establishes a simulation platform to acquire optimized result through simulation experiment.

  1. The speed control of DC motor under the load condition using PI and PID controllers

    Science.gov (United States)

    Corapsiz, Muhammed Reşit; Kahveci, Hakan

    2017-04-01

    In this study, it was aimed to compare PI (Proportional-Integral) and PID (Proportional-Integral-Derivative) controllers for speed control of Permanent Magnet Direct Current (PMDC) motor under both load and without load. For this purpose, firstly, the mathematical model was obtained from the dynamic equations of the PMDC motor and the obtained mathematical model was transferred to the simulation environment and modeled using Matlab/SIMULINK. Following the modeling process, PI and PID controller structures were formed, respectively. Secondly, after these structures were formed, the PMDC motor was run without any controller. Then, the control of the PMDC motor with no load was provided by using PI and PID controllers. Finally, the PMDC motor were loaded under the constant load (TL = 3 N.m.) for each condition and selected time period (t = 3 s). The obtained result for each control operations was comparatively given by observing effects of loading process on systems. When the obtained results were evaluated for each condition, it was observed that PID controller have the best performance with respect to PI controller.

  2. Multiple-Time-Scales Hierarchical Frequency Stability Control Strategy of Medium-Voltage Isolated Microgrid

    DEFF Research Database (Denmark)

    Zhao, Zhuoli; Yang, Ping; Guerrero, Josep M.

    2016-01-01

    In this paper, an islanded medium-voltage (MV) microgrid placed in Dongao Island is presented, which integrates renewable-energy-based distributed generations (DGs), energy storage system (ESS), and local loads. In an isolated microgrid without connection to the main grid to support the frequency......, it is more complex to control and manage. Thus in order to maintain the frequency stability in multiple-time-scales, a hierarchical control strategy is proposed. The proposed control architecture divides the system frequency in three zones: (A) stable zone, (B) precautionary zone and (C) emergency zone...... of Zone B. Theoretical analysis, time-domain simulation and field test results under various conditions and scenarios in the Dongao Island microgrid are presented to prove the validity of the introduced control strategy....

  3. High-performance control of a three-phase voltage-source converter including feedforward compensation of the estimated load current

    International Nuclear Information System (INIS)

    Leon, Andres E.; Solsona, Jorge A.; Busada, Claudio; Chiacchiarini, Hector; Valla, Maria Ines

    2009-01-01

    In this paper a new control strategy for voltage-source converters (VSC) is introduced. The proposed strategy consists of a nonlinear feedback controller based on feedback linearization plus a feedforward compensation of the estimated load current. In our proposal an energy function and the direct-axis current are considered as outputs, in order to avoid the internal dynamics. In this way, a full linearization is obtained via nonlinear transformation and feedback. An estimate of the load current is feedforwarded to improve the performance of the whole system and to diminish the capacitor size. This estimation allows to obtain a more rugged and cheaper implementation. The estimate is calculated by using a nonlinear reduced-order observer. The proposal is validated through different tests. These tests include performance in presence of switching frequency, measurement filters delays, parameters uncertainties and disturbances in the input voltage.

  4. Modeling nitrate-nitrogen load reduction strategies for the des moines river, iowa using SWAT

    Science.gov (United States)

    Schilling, K.E.; Wolter, C.F.

    2009-01-01

    The Des Moines River that drains a watershed of 16,175 km2 in portions of Iowa and Minnesota is impaired for nitrate-nitrogen (nitrate) due to concentrations that exceed regulatory limits for public water supplies. The Soil Water Assessment Tool (SWAT) model was used to model streamflow and nitrate loads and evaluate a suite of basin-wide changes and targeting configurations to potentially reduce nitrate loads in the river. The SWAT model comprised 173 subbasins and 2,516 hydrologic response units and included point and nonpoint nitrogen sources. The model was calibrated for an 11-year period and three basin-wide and four targeting strategies were evaluated. Results indicated that nonpoint sources accounted for 95% of the total nitrate export. Reduction in fertilizer applications from 170 to 50 kg/ha achieved the 38% reduction in nitrate loads, exceeding the 34% reduction required. In terms of targeting, the most efficient load reductions occurred when fertilizer applications were reduced in subbasins nearest the watershed outlet. The greatest load reduction for the area of land treated was associated with reducing loads from 55 subbasins with the highest nitrate loads, achieving a 14% reduction in nitrate loads achieved by reducing applications on 30% of the land area. SWAT model results provide much needed guidance on how to begin implementing load reduction strategies most efficiently in the Des Moines River watershed. ?? 2009 Springer Science+Business Media, LLC.

  5. Interactive Control System, Intended Strategy, Implemented Strategy dan Emergent Strategy

    OpenAIRE

    Tubagus Ismail; Darjat Sudrajat

    2012-01-01

    The purpose of this study was to examine the relationship between management control system (MCS) and strategy formation processes, namely: intended strategy, emergent strategy and impelemented strategy. The focus of MCS in this study was interactive control system. The study was based on Structural Equation Modeling (SEM) as its multivariate analyses instrument. The samples were upper middle managers of manufacturing company in Banten Province, DKI Jakarta Province and West Java Province. AM...

  6. Evaluation of cognitive loads imposed by traditional paper-based and innovative computer-based instructional strategies.

    Science.gov (United States)

    Khalil, Mohammed K; Mansour, Mahmoud M; Wilhite, Dewey R

    2010-01-01

    Strategies of presenting instructional information affect the type of cognitive load imposed on the learner's working memory. Effective instruction reduces extraneous (ineffective) cognitive load and promotes germane (effective) cognitive load. Eighty first-year students from two veterinary schools completed a two-section questionnaire that evaluated their perspectives on the educational value of a computer-based instructional program. They compared the difference between cognitive loads imposed by paper-based and computer-based instructional strategies used to teach the anatomy of the canine skeleton. Section I included 17 closed-ended items, rated on a five-point Likert scale, that assessed the use of graphics, content, and the learning process. Section II included a nine-point mental effort rating scale to measure the level of difficulty of instruction; students were asked to indicate the amount of mental effort invested in the learning task using both paper-based and computer-based presentation formats. The closed-ended data were expressed as means and standard deviations. A paired t test with an alpha level of 0.05 was used to determine the overall mean difference between the two presentation formats. Students positively evaluated their experience with the computer-based instructional program with a mean score of 4.69 (SD=0.53) for use of graphics, 4.70 (SD=0.56) for instructional content, and 4.45 (SD=0.67) for the learning process. The mean difference of mental effort (1.50) between the two presentation formats was significant, t=8.26, p≤.0001, df=76, for two-tailed distribution. Consistent with cognitive load theory, innovative computer-based instructional strategies decrease extraneous cognitive load compared with traditional paper-based instructional strategies.

  7. Integrating Autonomous Load Controllers in Power Systems

    DEFF Research Database (Denmark)

    Douglass, Philip James

    , but they are characterized by variable generation that is only partly predictable. Managing loads is already used in limited circumstances to improve security and efficiency of the power system. In power systems with a large penetration of variable generation, load management has large role to play in adapting consumption......Electric energy systems stand on the brink of radical change as the urgent need to reduce greenhouse gas emissions pushes more efficient utilization of energy resources and the adoption of renewable energy sources. New renewable sources such as wind and solar have a large potential......-sensitive load controller has been designed, implemented, and tested in real-life settings. Its performance demonstrated a large potential resource, in some cases greater than the average power consumption. The accuracy of load models was validated by comparison with field data. A voltage-sensitive controller...

  8. Pneumatic load compensating or controlling system

    Science.gov (United States)

    Rogers, J. R. (Inventor)

    1975-01-01

    A pneumatic load compensating or controlling system for restraining a load with a predetermined force or applying a predetermined force to the load is described; it includes a source of pressurized air, a one-way pneumatic actuator operatively connected to a load, and a fluid conduit fluidically connecting the actuator with the source of pressurized air. The actuator is of the piston and cylinder type, and the end of the fluid conduit is connected to the upper or lower portion of the cylinder whereby the actuator alternatively and selectively restrains the load with a predetermined force or apply a predetermined force to the load. Pressure regulators are included within the system for variably selectively adjusting the pressurized fluid to predetermined values as desired or required; a pressure amplifier is included within the system for multiplying the pressurized values so as to achieve greater load forces. An accumulator is incorporated within the system as a failsafe operating mechanism, and visual and aural alarm devices, operatively associated with pressure detecting apparatus, readily indicate the proper or improper functioning of the system.

  9. Adaptive pitch control for load mitigation of wind turbines

    Science.gov (United States)

    Yuan, Yuan; Tang, J.

    2015-04-01

    In this research, model reference adaptive control is examined for the pitch control of wind turbines that may suffer from reduced life owing to extreme loads and fatigue when operated under a high wind speed. Specifically, we aim at making a trade-off between the maximum energy captured and the load induced. The adaptive controller is designed to track the optimal generator speed and at the same time to mitigate component loads under turbulent wind field and other uncertainties. The proposed algorithm is tested on the NREL offshore 5-MW baseline wind turbine, and its performance is compared with that those of the gain scheduled proportional integral (GSPI) control and the disturbance accommodating control (DAC). The results show that the blade root flapwise load can be reduced at a slight expense of optimal power output. The generator speed regulation under adaptive controller is better than DAC.

  10. Optimal Load Control via Frequency Measurement and Neighborhood Area Communication

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, CH; Topcu, U; Low, SH

    2013-11-01

    We propose a decentralized optimal load control scheme that provides contingency reserve in the presence of sudden generation drop. The scheme takes advantage of flexibility of frequency responsive loads and neighborhood area communication to solve an optimal load control problem that balances load and generation while minimizing end-use disutility of participating in load control. Local frequency measurements enable individual loads to estimate the total mismatch between load and generation. Neighborhood area communication helps mitigate effects of inconsistencies in the local estimates due to frequency measurement noise. Case studies show that the proposed scheme can balance load with generation and restore the frequency within seconds of time after a generation drop, even when the loads use a highly simplified power system model in their algorithms. We also investigate tradeoffs between the amount of communication and the performance of the proposed scheme through simulation-based experiments.

  11. Evaluation of throughwall crack pipes under displacement controlled loading

    Energy Technology Data Exchange (ETDEWEB)

    Zahoor, A.

    1987-02-01

    Tearing modulus solutions are developed for flawed throughwall pipes subjected to displacement controlled loading. Two cases of loading were considered: (1) a displacement controlled bending loading, and (2) a displacement controlled axial tension loading. A revised version of the EPRI J-integral estimation scheme is used in the development of the solutions. These solutions can be used for the entire range of elastic-plastic loading, from linear elastic, contained yielding, to large scale yielding of the crack section. Experimental data from pipes in bending were used to assess the accuracy of the compliant loading solutions. The evaluations were performed using elastic plastic J-integral (J) and tearing modulus (T) analysis methods. These solutions are shown to have good accuracy when used to predict the experimental results. The methodology and procedure can also be applied to part-throughwall cracks. These solutions have application to the leak before break fracture mechanics analyses.

  12. Evaluation of throughwall crack pipes under displacement controlled loading

    International Nuclear Information System (INIS)

    Zahoor, A.

    1987-01-01

    Tearing modulus solutions are developed for flawed throughwall pipes subjected to displacement controlled loading. Two cases of loading were considered: (1) a displacement controlled bending loading, and (2) a displacement controlled axial tension loading. A revised version of the EPRI J-integral estimation scheme is used in the development of the solutions. These solutions can be used for the entire range of elastic-plastic loading, from linear elastic, contained yielding, to large scale yielding of the crack section. Experimental data from pipes in bending were used to assess the accuracy of the compliant loading solutions. The evaluations were performed using elastic plastic J-integral (J) and tearing modulus (T) analysis methods. These solutions are shown to have good accuracy when used to predict the experimental results. The methodology and procedure can also be applied to part-throughwall cracks. These solutions have application to the leak before break fracture mechanics analyses. (orig.)

  13. Sliding Mode Control for Pressurized-Water Nuclear Reactors in load following operations with bounded xenon oscillations

    International Nuclear Information System (INIS)

    Ansarifar, G.R.; Saadatzi, S.

    2015-01-01

    Highlights: • We present SMC which is a robust nonlinear controller to control the PWR power. • Xenon oscillations are kept bounded within acceptable limits. • The stability analysis has been based on Lyapunov approach. • Simulation results indicate the high performance of this new control. - Abstract: One of the important operations in nuclear power plants is load-following in which imbalance of axial power distribution induces xenon oscillations. These oscillations must be maintained within acceptable limits otherwise the nuclear power plant could become unstable. Therefore, bounded xenon oscillation considered to be a constraint for the load-following operation. In this paper, sliding mode control (SMC) which is a robust nonlinear controller is designed to control the Pressurized-Water Nuclear Reactor (PWR) power for the load-following operation problem that ensures xenon oscillations are kept bounded within acceptable limits. The proposed controller uses constant axial offset (AO) strategy to maintain xenon oscillations to be bounded. The constant AO is a robust state constraint for load-following problem. The reactor core is simulated based on the two-point nuclear reactor model and one delayed neutron group. The stability analysis is given by means Lyapunov approach, thus the control system is guaranteed to be stable within a large range. The employed method is easy to implement in practical applications and moreover, the sliding mode control exhibits the desired dynamic properties during the entire output-tracking process independent of perturbations. Simulation results are presented to demonstrate the effectiveness of the proposed controller in terms of performance, robustness and stability. Results show that the proposed controller for the load-following operation is sufficiently effective so that the xenon oscillations are kept bounded in the considered region

  14. Control strategy for power management, efficiency-optimization and operating-safety of a 5-kW solid oxide fuel cell system

    International Nuclear Information System (INIS)

    Zhang, Lin; Jiang, Jianhua; Cheng, Huan; Deng, Zhonghua; Li, Xi

    2015-01-01

    Highlights: • Efficiency optimization associated with simultaneous power and thermal management. • Fast load tracing, fuel starvation, high efficiency and operating safety are considered. • Open loop pre-conditioning current strategy is proposed for load step-up transients. • Feedback control scheme is proposed for load step-up transients. - Abstract: The slow power tracking, operating safety, especially the fuel exhaustion, and high efficiency considerations are the key issues for integrated solid oxide fuel cell (SOFC) systems during power step up transients, resulting in the relatively poor dynamic capabilities and make the transient load following very challenging and must be enhanced. To this end, this paper first focus on addressing the efficiency optimization associated with simultaneous power and thermal management of a 5-kW SOFC system. Particularly, a traverse optimization process including cubic convolution interpolation algorithm are proposed to obtain optimal operating points (OOPs) with the maximum efficiency. Then this paper investigate the current implications on system step-up transient performance, then a two stage pre-conditioning current strategy and a feedback power reference control scheme is proposed for load step-up transients to balance fast load following and fuel starvation, after that safe thermal transient is validated. Simulation results show the efficacy of the control design by demonstrating the fast load following ability while maintaining the safe operation, thus safe; efficient and fast load transition can be achieved

  15. A Wireless Power Sharing Control Strategy for Hybrid Energy Storage Systems in DC Microgrids

    DEFF Research Database (Denmark)

    Yang, Jie; Jin, Xinmin; Wu, Xuezhi

    2017-01-01

    In order to compensate multiple time scales power fluctuation resulted from distributed energy resources and loads, hybrid energy storage systems are employed as the buffer unit in DC microgrid. In this paper, a wireless hierarchical control strategy is proposed to realize power sharing between...

  16. A Hybrid Power Control Concept for PV Inverters with Reduced Thermal Loading

    DEFF Research Database (Denmark)

    Yang, Yongheng; Wang, Huai; Blaabjerg, Frede

    2014-01-01

    on a single-phase PV inverter under yearly operation is presented with analyses of the thermal loading, lifetime, and annual energy yield. It has revealed the trade-off factors to select the power limit and also verified the feasibility and the effectiveness of the proposed control concept.......This letter proposes a hybrid power control concept for grid-connected Photovoltaic (PV) inverters. The control strategy is based on either a Maximum Power Point Tracking (MPPT) control or a Constant Power Generation (CPG) control depending on the instantaneous available power from the PV panels....... The essence of the proposed concept lies in the selection of an appropriate power limit for the CPG control to achieve an improved thermal performance and an increased utilization factor of PV inverters,and thus to cater for a higher penetration level of PV systems with intermittent nature. A case study...

  17. Different Optimal Control Strategies for Exploitation of Demand Response in the Smart Grid

    DEFF Research Database (Denmark)

    Zong, Yi; Bindner, Henrik W.; Gehrke, Oliver

    2012-01-01

    To achieve a Danish energy supply based on 100% renewable energy from combinations of wind, biomass, wave and solar power in 2050 and to cover 50% of the Danish electricity consumption by wind power in 2025, it requires coordinated management of large numbers of distributed and demand response...... resources, intermittent renewable energy resources in the Smart Grid. This paper presents different optimal control (Genetic Algorithm-based and Model Predictive Control-based) algorithms that schedule controlled loads in the industrial and residential sectors, based on dynamic price and weather forecast......, considering users’ comfort settings to meet an optimization objective, such as maximum profit or minimum energy consumption. It is demonstrated in this work that the GA-based and MPC-based optimal control strategies are able to achieve load shifting for grid reliability and energy savings, including demand...

  18. Research on Control Strategy of the Micro Grid’s Hybrid Energy System

    Science.gov (United States)

    Gao, Zi-jun; Li, Yang; Wang, Yan-ping; Zong, Ke-yong; Zhang, Jing

    2018-03-01

    This paper study the structure and operating characteristic of the hybrid energy system which is made of super-capacitor and battery. The system is controlled by strategy of bus voltage following. The bus voltage can change the state from swings to stable quickly when load mutation occurs in the micro grid. The transient impact also can be reduced by this way. The passage set up the model of energy system and make an analysis by the software named MATLAB/Simulink. At last, the passage proves the correctness and the effectiveness of the control strategy and draws a conclusion that the transient impact can be inhibited which occurs in the bus voltage of energy system.

  19. The Research on Operation Strategy of Nuclear Power Plant with Multi-reactors

    Energy Technology Data Exchange (ETDEWEB)

    Fang, Maoyao; Peng, Minjun; Cheng Shouyu [Harbin Engineering University, Harbin (China)

    2014-08-15

    In this paper, the operation characteristics and control strategy of nuclear power plant (NPP) with multi-modular pressurized water reactors (PWR) were researched through simulation. The main objective of this research was to ensure the coordinated operation and satisfy the convenience of turbine-generator and reactor's load adjustment in NPP with multi-reactors (MR). According to the operation characteristics of MR-NPP, the operation and control strategy was proposed, which was 'he average allocation of load for each reactor and maintaining average temperature of coolant at a constant? The control system was designed based the operation and control strategy. In order to research the operation characteristics and control strategy of MR-NPP, the paper established the transient analysis model which included the reactors and thermal hydraulic models, turbine model, could simulate and analyze on different operating conditions such as load reducing, load rising. Based on the proposed operation and control strategy and simulation models, the paper verified and validated the operation strategy and control system through load reducing, load rising. The results of research simulation showed that the operation strategy was feasible and can make the MR-NPP running safely as well as steadily on different operating conditions.

  20. The Research on Operation Strategy of Nuclear Power Plant with Multi-reactors

    International Nuclear Information System (INIS)

    Fang, Maoyao; Peng, Minjun; Cheng Shouyu

    2014-01-01

    In this paper, the operation characteristics and control strategy of nuclear power plant (NPP) with multi-modular pressurized water reactors (PWR) were researched through simulation. The main objective of this research was to ensure the coordinated operation and satisfy the convenience of turbine-generator and reactor's load adjustment in NPP with multi-reactors (MR). According to the operation characteristics of MR-NPP, the operation and control strategy was proposed, which was 'he average allocation of load for each reactor and maintaining average temperature of coolant at a constant? The control system was designed based the operation and control strategy. In order to research the operation characteristics and control strategy of MR-NPP, the paper established the transient analysis model which included the reactors and thermal hydraulic models, turbine model, could simulate and analyze on different operating conditions such as load reducing, load rising. Based on the proposed operation and control strategy and simulation models, the paper verified and validated the operation strategy and control system through load reducing, load rising. The results of research simulation showed that the operation strategy was feasible and can make the MR-NPP running safely as well as steadily on different operating conditions

  1. Direct Load Control by AC Frequency Modulation

    DEFF Research Database (Denmark)

    Douglass, Philip James; You, Shi

    2012-01-01

    Fine-grained under frequency load shedding called “demand as a frequency controlled reserve“ (DFCR) has been shown to be a promising method of providingfrequency regulation service from distributed loads [1]. Micro-grids with a large portion of intermittent renewable generation will benefit greatly...... from this technology because their low inertia. The paper proposes a operating procedure for utilizing DFCR loads for energy balancing, expanding DFCR’s well known role as a power balancing resource. The system operator can use DFCR for energy balancing by adjusting the frequency controller...... of generators to schedule off-nominal system frequency values. The feasibility of the proposed system is evaluated on an existing small island power system....

  2. Experimental Study of a Centralized Control Strategy of a DC Microgrid Working in Grid Connected Mode

    Directory of Open Access Journals (Sweden)

    Robert Salas-Puente

    2017-10-01

    Full Text Available The results concerning the integration of a set of power management strategies and serial communications for the efficient coordination of the power converters composing an experimental DC microgrid is presented. The DC microgrid operates in grid connected mode by means of an interlinking converter. The overall control is carried out by means of a centralized microgrid controller implemented on a Texas Instruments TMS320F28335 DSP. The main objectives of the applied control strategies are to ensure the extract/inject power limits established by the grid operator as well as the renewable generation limits if it is required; to devise a realistic charging procedure of the energy storage batteries as a function of the microgrid status; to manage sudden changes of the available power from the photovoltaic energy sources, of the load power demand and of the power references established by the central controller; and to implement a load shedding functionality. The experimental results demonstrate that the proposed power management methodology allows the control of the power dispatch inside the DC microgrid properly.

  3. Wind integration in self-regulating electric load distributions

    Energy Technology Data Exchange (ETDEWEB)

    Parkinson, Simon; Wang, Dan; Crawford, Curran; Djilali, Ned [University of Victoria, Department of Mechanical Engineering, Institute for Integrated Energy Systems, STN CSC, Victoria, BC (Canada)

    2012-12-15

    The purpose of this paper is to introduce and assess an alternative method of mitigating short-term wind energy production variability through the control of electric loads. In particular, co-located populations of electric vehicles and heat pumps are targeted to provide regulation-based ancillary services, as the inherent operational flexibility and autonomous device-level control strategy associated with these load-types provide an ideal platform to mitigate enhanced variability within the power system. An optimal control strategy capable of simultaneously balancing these grid-side objectives with those typically expected on the demand-side is introduced. End-use digital communication hardware is used to track and control population dynamics through the development of online aggregate load models equivalent to conventional dispatchable generation. The viability of the proposed load control strategy is assessed through model-based simulations that explicitly track end-use functionality of responsive devices within a power systems analysis typically implemented to observe the effects of integrated wind energy systems. Results indicate that there is great potential for the proposed method to displace the need for increased online regulation reserve capacity in systems considering a high penetration of wind energy, thereby allowing conventional generation to operate more efficiently. (orig.)

  4. Optimal Load-Tracking Operation of Grid-Connected Solid Oxide Fuel Cells through Set Point Scheduling and Combined L1-MPC Control

    Directory of Open Access Journals (Sweden)

    Siwei Han

    2018-03-01

    Full Text Available An optimal load-tracking operation strategy for a grid-connected tubular solid oxide fuel cell (SOFC is studied based on the steady-state analysis of the system thermodynamics and electrochemistry. Control of the SOFC is achieved by a two-level hierarchical control system. In the upper level, optimal setpoints of output voltage and the current corresponding to unit load demand is obtained through a nonlinear optimization by minimizing the SOFC’s internal power waste. In the lower level, a combined L1-MPC control strategy is designed to achieve fast set point tracking under system nonlinearities, while maintaining a constant fuel utilization factor. To prevent fuel starvation during the transient state resulting from the output power surging, a fuel flow constraint is imposed on the MPC with direct electron balance calculation. The proposed control schemes are testified on the grid-connected SOFC model.

  5. Optimal Control Allocation with Load Sensor Feedback for Active Load Suppression, Flight-Test Performance

    Science.gov (United States)

    Miller, Christopher J.; Goodrick, Dan

    2017-01-01

    The problem of control command and maneuver induced structural loads is an important aspect of any control system design. The aircraft structure and the control architecture must be designed to achieve desired piloted control responses while limiting the imparted structural loads. The classical approach is to utilize high structural margins, restrict control surface commands to a limited set of analyzed combinations, and train pilots to follow procedural maneuvering limitations. With recent advances in structural sensing and the continued desire to improve safety and vehicle fuel efficiency, it is both possible and desirable to develop control architectures that enable lighter vehicle weights while maintaining and improving protection against structural damage. An optimal control technique has been explored and shown to achieve desirable vehicle control performance while limiting sensed structural loads to specified values. This technique has been implemented and flown on the National Aeronautics and Space Administration Full-scale Advanced Systems Testbed aircraft. The flight tests illustrate that the approach achieves the desired performance and show promising potential benefits. The flights also uncovered some important issues that will need to be addressed for production application.

  6. A robust control strategy for mitigating renewable energy fluctuations in a real hybrid power system combined with SMES

    Science.gov (United States)

    Magdy, G.; Shabib, G.; Elbaset, Adel A.; Qudaih, Yaser; Mitani, Yasunori

    2018-05-01

    Utilizing Renewable Energy Sources (RESs) is attracting great attention as a solution to future energy shortages. However, the irregular nature of RESs and random load deviations cause a large frequency and voltage fluctuations. Therefore, in order to benefit from a maximum capacity of the RESs, a robust mitigation strategy of power fluctuations from RESs must be applied. Hence, this paper proposes a design of Load Frequency Control (LFC) coordinated with Superconducting Magnetic Energy Storage (SMES) technology (i.e., an auxiliary LFC), using an optimal PID controller-based Particle Swarm Optimization (PSO) in the Egyptian Power System (EPS) considering high penetration of Photovoltaics (PV) power generation. Thus, from the perspective of LFC, the robust control strategy is proposed to maintain the nominal system frequency and mitigating the power fluctuations from RESs against all disturbances sources for the EPS with the multi-source environment. The EPS is decomposed into three dynamics subsystems, which are non-reheat, reheat and hydro power plants taking into consideration the system nonlinearity. The results by nonlinear simulation Matlab/Simulink for the EPS combined with SMES system considering PV solar power approves that, the proposed control strategy achieves a robust stability by reducing transient time, minimizing the frequency deviations, maintaining the system frequency, preventing conventional generators from exceeding their power ratings during load disturbances, and mitigating the power fluctuations from the RESs.

  7. A robust adaptive load frequency control for micro-grids.

    Science.gov (United States)

    Khooban, Mohammad-Hassan; Niknam, Taher; Blaabjerg, Frede; Davari, Pooya; Dragicevic, Tomislav

    2016-11-01

    The goal of this study is to introduce a novel robust load frequency control (LFC) strategy for micro-grid(s) (MG(s)) in islanded mode operation. Admittedly, power generators in MG(s) cannot supply steady electric power output and sometimes cause unbalance between supply and demand. Battery energy storage system (BESS) is one of the effective solutions to these problems. Due to the high cost of the BESS, a new idea of Vehicle-to-Grid (V2G) is that a battery of Electric-Vehicle (EV) can be applied as a tantamount large-scale BESS in MG(s). As a result, a new robust control strategy for an islanded micro-grid (MG) is introduced that can consider electric vehicles׳ (EV(s)) effect. Moreover, in this paper, a new combination of the General Type II Fuzzy Logic Sets (GT2FLS) and the Modified Harmony Search Algorithm (MHSA) technique is applied for adaptive tuning of proportional-integral (PI) controller. Implementing General Type II Fuzzy Systems is computationally expensive. However, using a recently introduced α-plane representation, GT2FLS can be seen as a composition of several Interval Type II Fuzzy Logic Systems (IT2FLS) with a corresponding level of α for each. Real-data from an offshore wind farm in Sweden and solar radiation data in Aberdeen (United Kingdom) was used in order to examine the performance of the proposed novel controller. A comparison is made between the achieved results of Optimal Fuzzy-PI (OFPI) controller and those of Optimal Interval Type II Fuzzy-PI (IT2FPI) controller, which are of most recent advances in the area at hand. The Simulation results prove the successfulness and effectiveness of the proposed controller. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.

  8. Review of Active and Reactive Power Sharing Strategies in Hierarchical Controlled Microgrids

    DEFF Research Database (Denmark)

    Han, Yang; Li, Hong; Shen, Pan

    2017-01-01

    Microgrids consist of multiple parallel-connected distributed generation (DG) units with coordinated control strategies, which are able to operate in both grid-connected and islanded mode. Microgrids are attracting more and more attention since they can alleviate the stress of main transmission...... systems, reduce feeder losses, and improve system power quality. When the islanded microgrids are concerned, it is important to maintain system stability and achieve load power sharing among the multiple parallel-connected DG units. However, the poor active and reactive power sharing problems due...... in this paper for active power sharing. Moreover, nonlinear and unbalanced loads could further affect the reactive power sharing when regulating the active power, and it is difficult to share the reactive power accurately only by using the enhanced virtual impedance method. Therefore, the hierarchical control...

  9. Multi objective large power system planning under sever loading condition using learning DE-APSO-PS strategy

    International Nuclear Information System (INIS)

    Mahdad, Belkacem; Srairi, K.

    2014-01-01

    Highlights: • An efficient planning strategy using DE and APSO in coordination with PS algorithm is proposed. • An interactive process is proposed to balance the exploitation and exploration capability of (DE-APSO) and PS. • Fuel cost, power loss, and voltage deviation considering loading condition are optimized. • The proposed strategy (DE-APSO-PS) is validated on three large practical test systems. - Abstract: This paper introduces an efficient planning strategy using new hybrid interactive differential evolution (DE), adaptive particle swarm optimization (APSO), and pattern search (PS) for solving the security optimal power flow (SOPF) considering multi distributed static VAR compensator (SVC). Three objective functions such as fuel cost, power loss and voltage deviation are considered and optimized considering sever loading conditions. The main idea of the proposed strategy is that variable controls are optimized based on superposition mechanism, the best solutions evaluated by DE and APSO at specified stages are communicated to PS to exploit new regions around this solution, alternatively the new solution achieved by PS is also communicated to DE and APSO, this interactive mechanism search between global and local search is to balance the exploitation and exploration capability which allows individuals from different methods to react more by learning and changing experiences. The robustness of the proposed strategy is tested and validated on large practical power system test (IEEE 118-Bus, IEEE 300-Bus, and 40 units). Comparison results with the standard global optimization methods such as DE, APSO PS and to other recent techniques showed the superiority and perspective of the proposed hybrid technique for solving practical power system problems

  10. Adaptive sliding control of non-autonomous active suspension systems with time-varying loadings

    Science.gov (United States)

    Chen, Po-Chang; Huang, An-Chyau

    2005-04-01

    An adaptive sliding controller is proposed in this paper for controlling a non-autonomous quarter-car suspension system with time-varying loadings. The bound of the car-body loading is assumed to be available. Then, the reference coordinate is placed at the static position under the nominal loading so that the system dynamic equation is derived. Due to spring nonlinearities, the system property becomes asymmetric after coordinate transformation. Besides, in practical cases, system parameters are not easy to be obtained precisely for controller design. Therefore, in this paper, system uncertainties are lumped into two unknown time-varying functions. Since the variation bound of one of the unknown functions is not available, conventional adaptive schemes and robust designs are not applicable. To deal with this problem, the function approximation technique is employed to represent the unknown function as a finite combination of basis functions. The Lyapunov direct method can thus be used to find adaptive laws for updating coefficients in the approximating series and to prove stability of the closed-loop system. Since the position and velocity measurements of the unsprung mass are lumped into the unknown function, there is no need to install sensors on the axle and wheel assembly in the actual implementation. Simulation results are presented to show the performance of the proposed strategy.

  11. Control system options and strategies for supercritical CO2 cycles.

    Energy Technology Data Exchange (ETDEWEB)

    Moisseytsev, A.; Kulesza, K. P.; Sienicki, J. J.; Nuclear Engineering Division; Oregon State Univ.

    2009-06-18

    The Supercritical Carbon Dioxide (S-CO{sub 2}) Brayton Cycle is a promising alternative to Rankine steam cycle and recuperated gas Brayton cycle energy converters for use with Sodium-Cooled Fast Reactors (SFRs), Lead-Cooled Fast Reactors (LFRs), as well as other advanced reactor concepts. The S-CO{sub 2} Brayton Cycle offers higher plant efficiencies than Rankine or recuperated gas Brayton cycles operating at the same liquid metal reactor core outlet temperatures as well as reduced costs or size of key components especially the turbomachinery. A new Plant Dynamics Computer Code has been developed at Argonne National Laboratory for simulation of a S-CO{sub 2} Brayton Cycle energy converter coupled to an autonomous load following liquid metal-cooled fast reactor. The Plant Dynamics code has been applied to investigate the effectiveness of a control strategy for the S-CO{sub 2} Brayton Cycle for the STAR-LM 181 MWe (400 MWt) Lead-Cooled Fast Reactor. The strategy, which involves a combination of control mechanisms, is found to be effective for controlling the S-CO{sub 2} Brayton Cycle over the complete operating range from 0 to 100 % load for a representative set of transient load changes. While the system dynamic analysis of control strategy performance for STARLM is carried out for a S-CO{sub 2} Brayton Cycle energy converter incorporating an axial flow turbine and compressors, investigations of the S-CO{sub 2} Brayton Cycle have identified benefits from the use of centrifugal compressors which offer a wider operating range, greater stability near the critical point, and potentially further cost reductions due to fewer stages than axial flow compressors. Models have been developed at Argonne for the conceptual design and performance analysis of centrifugal compressors for use in the SCO{sub 2} Brayton Cycle. Steady state calculations demonstrate the wider operating range of centrifugal compressors versus axial compressors installed in a S-CO{sub 2} Brayton Cycle as

  12. Control system options and strategies for supercritical CO2 cycles

    International Nuclear Information System (INIS)

    Moisseytsev, A.; Kulesza, K.P.; Sienicki, J.J.

    2009-01-01

    The Supercritical Carbon Dioxide (S-CO 2 ) Brayton Cycle is a promising alternative to Rankine steam cycle and recuperated gas Brayton cycle energy converters for use with Sodium-Cooled Fast Reactors (SFRs), Lead-Cooled Fast Reactors (LFRs), as well as other advanced reactor concepts. The S-CO 2 Brayton Cycle offers higher plant efficiencies than Rankine or recuperated gas Brayton cycles operating at the same liquid metal reactor core outlet temperatures as well as reduced costs or size of key components especially the turbomachinery. A new Plant Dynamics Computer Code has been developed at Argonne National Laboratory for simulation of a S-CO 2 Brayton Cycle energy converter coupled to an autonomous load following liquid metal-cooled fast reactor. The Plant Dynamics code has been applied to investigate the effectiveness of a control strategy for the S-CO 2 Brayton Cycle for the STAR-LM 181 MWe (400 MWt) Lead-Cooled Fast Reactor. The strategy, which involves a combination of control mechanisms, is found to be effective for controlling the S-CO 2 Brayton Cycle over the complete operating range from 0 to 100 % load for a representative set of transient load changes. While the system dynamic analysis of control strategy performance for STARLM is carried out for a S-CO 2 Brayton Cycle energy converter incorporating an axial flow turbine and compressors, investigations of the S-CO 2 Brayton Cycle have identified benefits from the use of centrifugal compressors which offer a wider operating range, greater stability near the critical point, and potentially further cost reductions due to fewer stages than axial flow compressors. Models have been developed at Argonne for the conceptual design and performance analysis of centrifugal compressors for use in the SCO 2 Brayton Cycle. Steady state calculations demonstrate the wider operating range of centrifugal compressors versus axial compressors installed in a S-CO 2 Brayton Cycle as well as the benefits in expanding the range

  13. A novel harmonic current sharing control strategy for parallel-connected inverters

    DEFF Research Database (Denmark)

    Guan, Yajuan; Guerrero, Josep M.; Savaghebi, Mehdi

    2017-01-01

    A novel control strategy which enables proportional linear and nonlinear loads sharing among paralleled inverters and voltage harmonic suppression is proposed in this paper. The proposed method is based on the autonomous currents sharing controller (ACSC) instead of conventional power droop control...... to provide fast transient response, decoupling control and large stability margin. The current components at different sequences and orders are decomposed by a multi-second-order generalized integrator-based frequency locked loop (MSOGI-FLL). A harmonic-orthogonal-virtual-resistances controller (HOVR......) is used to proportionally share current components at different sequences and orders independently among the paralleled inverters. Proportional resonance controllers tuned at selected frequencies are used to suppress voltage harmonics. Simulations based on two 2.2 kW paralleled three-phase inverters...

  14. Evolution strategy based optimal chiller loading for saving energy

    International Nuclear Information System (INIS)

    Chang, Y.-C.; Lee, C.-Y.; Chen, C.-R.; Chou, C.-J.; Chen, W.-H.; Chen, W.-H.

    2009-01-01

    This study employs evolution strategy (ES) to solve optimal chiller loading (OCL) problem. ES overcomes the flaw that Lagrangian method is not adaptable for solving OCL as the power consumption models or the kW-PLR (partial load ratio) curves include convex functions and concave functions simultaneously. The complicated process of evolution by the genetic algorithm (GA) method for solving OCL can also be simplified by the ES method. This study uses the PLR of chiller as the variable to be solved for the decoupled air conditioning system. After analysis and comparison of the case study, it has been concluded that this method not only solves the problems of Lagrangian method and GA method, but also produces results with high accuracy within a rapid timeframe. It can be perfectly applied to the operation of air conditioning systems

  15. Room air conditioner load control under summer comfort constraint

    OpenAIRE

    Da Silva , David; Brancaccio , M; Duplessis , Bruno; Adnot , J

    2010-01-01

    International audience; Load control options interest is growing because it can represent a response to future network investments and to congestion problems. In this frame, the present paper gives a methodology to quantify the value of load control for heat pumps (room air conditioners), in small tertiary and residential buildings, considering the occupant's comfort and the electrical grid needs for load shift. This methodology was applied to a small office building where simulations were ma...

  16. A Wind Farm Active Power Dispatch Strategy for Fatigue Load Reduction

    DEFF Research Database (Denmark)

    Zhang, Baohua; N. Soltani, Mohsen; Hu, Weihao

    2016-01-01

    One of the biggest challenges in wind farm management is to cope with requirements from the grid companies and to optimize efficiency and minimize wear on wind turbines. This paper addresses an optimized active power dispatch strategy of a wind farm to reduce the fatigue load of wind turbines, wh...

  17. Development of Strategy Generator for PWRs Core Maneuver

    International Nuclear Information System (INIS)

    Deswandri

    2003-01-01

    Generally, nuclear power plants are utilized for base-load operation. However, if the nuclear capacity constitutes a large fraction of the total electric capacity in a country, the ability of nuclear power plants to perform load following operation is inevitable. In the load following operation, the reactor power is adjusted based on the fluctuation of electric power demand in the grid. That changes of power level can cause unbalance in the reactor, therefore, the control actions should be done during the power maneuvering. In order that the control actions could be effective and efficient, guidance for the reactor operators is needed. Strategy generator refers to a tool which provides guidance for operators as to control actions to be taken. This work developed the strategy generator based on the three concepts of control strategy. By numerical simulation, performance of these three strategies was tested and compared. The simulation result shows the unique characteristic for each strategy and discussion was provided to evaluate the abilities of each strategy in achieving the control targets. (author)

  18. A Virtual Inertia Control Strategy for DC Microgrids Analogized with Virtual Synchronous Machines

    DEFF Research Database (Denmark)

    Wu, Wenhua; Chen, Yandong; Luo, An

    2017-01-01

    In a DC microgrid (DC-MG), the dc bus voltage is vulnerable to power fluctuation derived from the intermittent distributed energy or local loads variation. In this paper, a virtual inertia control strategy for DC-MG through bidirectional grid-connected converters (BGCs) analogized with virtual...... synchronous machine (VSM) is proposed to enhance the inertia of the DC-MG, and to restrain the dc bus voltage fluctuation. The small-signal model of the BGC system is established, and the small-signal transfer function between the dc bus voltage and the dc output current of the BGC is deduced. The dynamic...... for the BGC is introduced to smooth the dynamic response of the dc bus voltage. By analyzing the control system stability, the appropriate virtual inertia control parameters are selected. Finally, simulations and experiments verified the validity of the proposed control strategy....

  19. An expert system for pressurized water reactor load maneuvers

    International Nuclear Information System (INIS)

    Chaung Lin; Jungping Chen; Yihjiunn Lin; Lianshin Lin

    1993-01-01

    Restartup after reactor shutdown and load-follow operations are the important tasks in operating pressurized water reactors. Generally, the most efficient method is to apply constant axial offset control (CAOC) strategy during load maneuvers. An expert system using CAOC strategy, fuzzy reasoning, a two-node core model, and operational constraints has been developed. The computation time is so short that this system, which leads to an approximate closed-loop control, could be useful for on-site calculation

  20. Finite-time adaptive sliding mode force control for electro-hydraulic load simulator based on improved GMS friction model

    Science.gov (United States)

    Kang, Shuo; Yan, Hao; Dong, Lijing; Li, Changchun

    2018-03-01

    This paper addresses the force tracking problem of electro-hydraulic load simulator under the influence of nonlinear friction and uncertain disturbance. A nonlinear system model combined with the improved generalized Maxwell-slip (GMS) friction model is firstly derived to describe the characteristics of load simulator system more accurately. Then, by using particle swarm optimization (PSO) algorithm ​combined with the system hysteresis characteristic analysis, the GMS friction parameters are identified. To compensate for nonlinear friction and uncertain disturbance, a finite-time adaptive sliding mode control method is proposed based on the accurate system model. This controller has the ability to ensure that the system state moves along the nonlinear sliding surface to steady state in a short time as well as good dynamic properties under the influence of parametric uncertainties and disturbance, which further improves the force loading accuracy and rapidity. At the end of this work, simulation and experimental results are employed to demonstrate the effectiveness of the proposed sliding mode control strategy.

  1. Real-Time Load-Side Control of Electric Power Systems

    Science.gov (United States)

    Zhao, Changhong

    Two trends are emerging from modern electric power systems: the growth of renewable (e.g., solar and wind) generation, and the integration of information technologies and advanced power electronics. The former introduces large, rapid, and random fluctuations in power supply, demand, frequency, and voltage, which become a major challenge for real-time operation of power systems. The latter creates a tremendous number of controllable intelligent endpoints such as smart buildings and appliances, electric vehicles, energy storage devices, and power electronic devices that can sense, compute, communicate, and actuate. Most of these endpoints are distributed on the load side of power systems, in contrast to traditional control resources such as centralized bulk generators. This thesis focuses on controlling power systems in real time, using these load side resources. Specifically, it studies two problems. (1) Distributed load-side frequency control: We establish a mathematical framework to design distributed frequency control algorithms for flexible electric loads. In this framework, we formulate a category of optimization problems, called optimal load control (OLC), to incorporate the goals of frequency control, such as balancing power supply and demand, restoring frequency to its nominal value, restoring inter-area power flows, etc., in a way that minimizes total disutility for the loads to participate in frequency control by deviating from their nominal power usage. By exploiting distributed algorithms to solve OLC and analyzing convergence of these algorithms, we design distributed load-side controllers and prove stability of closed-loop power systems governed by these controllers. This general framework is adapted and applied to different types of power systems described by different models, or to achieve different levels of control goals under different operation scenarios. We first consider a dynamically coherent power system which can be equivalently modeled with

  2. Predictive control strategy of a gas turbine for improvement of combined cycle power plant dynamic performance and efficiency.

    Science.gov (United States)

    Mohamed, Omar; Wang, Jihong; Khalil, Ashraf; Limhabrash, Marwan

    2016-01-01

    This paper presents a novel strategy for implementing model predictive control (MPC) to a large gas turbine power plant as a part of our research progress in order to improve plant thermal efficiency and load-frequency control performance. A generalized state space model for a large gas turbine covering the whole steady operational range is designed according to subspace identification method with closed loop data as input to the identification algorithm. Then the model is used in developing a MPC and integrated into the plant existing control strategy. The strategy principle is based on feeding the reference signals of the pilot valve, natural gas valve, and the compressor pressure ratio controller with the optimized decisions given by the MPC instead of direct application of the control signals. If the set points for the compressor controller and turbine valves are sent in a timely manner, there will be more kinetic energy in the plant to release faster responses on the output and the overall system efficiency is improved. Simulation results have illustrated the feasibility of the proposed application that has achieved significant improvement in the frequency variations and load following capability which are also translated to be improvements in the overall combined cycle thermal efficiency of around 1.1 % compared to the existing one.

  3. Model Predictive Control for Load Frequency Control with Wind Turbines

    Directory of Open Access Journals (Sweden)

    Yi Zhang

    2015-01-01

    Full Text Available Reliable load frequency (LFC control is crucial to the operation and design of modern electric power systems. Considering the LFC problem of a four-area interconnected power system with wind turbines, this paper presents a distributed model predictive control (DMPC based on coordination scheme. The proposed algorithm solves a series of local optimization problems to minimize a performance objective for each control area. The scheme incorporates the two critical nonlinear constraints, for example, the generation rate constraint (GRC and the valve limit, into convex optimization problems. Furthermore, the algorithm reduces the impact on the randomness and intermittence of wind turbine effectively. A performance comparison between the proposed controller with and that without the participation of the wind turbines is carried out. Good performance is obtained in the presence of power system nonlinearities due to the governors and turbines constraints and load change disturbances.

  4. A control strategy for PV stand-alone applications

    International Nuclear Information System (INIS)

    Slouma, S; Baccar, H

    2015-01-01

    This paper proposes a stand-alone photovoltaic (PV) system study in domestic applications. Because of the decrease in power of photovoltaic module as a consequence of changes in solar radiation and temperature which affect the photovoltaic module performance, the design and control of DC-DC buck converter was proposed for providing power to the load from a photovoltaic source.In fact, the control of this converter is carried out with integrated MPPT (Maximum Power Point Tracking) algorithm which ensures a maximum energy generated by the PV arrays. Moreover, the output stage is composed by a battery energy storage system, dc-ac inverter, LCL filter which enables higher efficiency, low distortion ac waveforms and low leakage currents. The control strategy adopted is cascade control composed by two regulation loops.Simulations performed with PSIM software were able to validate the control system.The realization and testing of the photovoltaic system were achieved in the Photovoltaic laboratory of the Centre for Research and Energy Technologies at the Technopark Borj Cedria. Experimental results verify the effeciency of the proposed system

  5. A control strategy for PV stand-alone applications

    Science.gov (United States)

    Slouma, S.; Baccar, H.

    2015-04-01

    This paper proposes a stand-alone photovoltaic (PV) system study in domestic applications. Because of the decrease in power of photovoltaic module as a consequence of changes in solar radiation and temperature which affect the photovoltaic module performance, the design and control of DC-DC buck converter was proposed for providing power to the load from a photovoltaic source.In fact, the control of this converter is carried out with integrated MPPT (Maximum Power Point Tracking) algorithm which ensures a maximum energy generated by the PV arrays. Moreover, the output stage is composed by a battery energy storage system, dc-ac inverter, LCL filter which enables higher efficiency, low distortion ac waveforms and low leakage currents. The control strategy adopted is cascade control composed by two regulation loops.Simulations performed with PSIM software were able to validate the control system.The realization and testing of the photovoltaic system were achieved in the Photovoltaic laboratory of the Centre for Research and Energy Technologies at the Technopark Borj Cedria. Experimental results verify the effeciency of the proposed system.

  6. Compensation for loads during arm movements using equilibrium-point control.

    Science.gov (United States)

    Gribble, P L; Ostry, D J

    2000-12-01

    A significant problem in motor control is how information about movement error is used to modify control signals to achieve desired performance. A potential source of movement error and one that is readily controllable experimentally relates to limb dynamics and associated movement-dependent loads. In this paper, we have used a position control model to examine changes to control signals for arm movements in the context of movement-dependent loads. In the model, based on the equilibrium-point hypothesis, equilibrium shifts are adjusted directly in proportion to the positional error between desired and actual movements. The model is used to simulate multi-joint movements in the presence of both "internal" loads due to joint interaction torques, and externally applied loads resulting from velocity-dependent force fields. In both cases it is shown that the model can achieve close correspondence to empirical data using a simple linear adaptation procedure. An important feature of the model is that it achieves compensation for loads during movement without the need for either coordinate transformations between positional error and associated corrective forces, or inverse dynamics calculations.

  7. Coordinated control of distributed energy resources to support load frequency control

    International Nuclear Information System (INIS)

    Ravikumar Pandi, V.; Al-Hinai, A.; Feliachi, Ali

    2015-01-01

    Highlights: • We aims to maintain feeder power flow by the coordination of DER units. • The error in feeder flow with respect to scheduled value is used by the controller. • The particle swarm optimization is employed to minimize the error in feeder flow. • Implemented on a transmission system along with 37 bus distribution feeder. • The results of proposed feeder control is analyzed with no feeder control scheme. - Abstract: The control of generating resources to follow the unscheduled load changes is considered to be an essential process in the power system in order to maintain the frequency of power supply. This load frequency control (LFC) problem has been given more importance in the recent smart grid environment because of the impact from high penetration of distributed energy resources (DER) installed at the distribution level. The renewable sources are highly intermittent in nature, so it is required to coordinate and control the DER units to maintain the feeder power flow at substation bus bar which is seen by transmission system operator during the LFC process. This paper aims to identify the impact of distributed generation and its control method to reduce the deviation of feeder power flow from the scheduled value in real time operation. The error in feeder power flow with respect to scheduled value is utilized by the PI controller to estimate the change in power reference of all DER units. The power output of DER units are maintained to reference values by the individual PI controllers. The particle swarm optimization algorithm is employed to minimize the error in feeder power flow by optimally tuning the gain values of all PI controllers. The proposed method is examined on a small transmission system along with the feeder of IEEE 37 bus distribution system with balanced loading condition. The complete system along with DER units is implemented in the MATLAB based stability package named Power Analysis Toolbox (PAT) for performing time domain

  8. A strategy to load balancing for non-connectivity MapReduce job

    Science.gov (United States)

    Zhou, Huaping; Liu, Guangzong; Gui, Haixia

    2017-09-01

    MapReduce has been widely used in large scale and complex datasets as a kind of distributed programming model. Original Hash partitioning function in MapReduce often results the problem of data skew when data distribution is uneven. To solve the imbalance of data partitioning, we proposes a strategy to change the remaining partitioning index when data is skewed. In Map phase, we count the amount of data which will be distributed to each reducer, then Job Tracker monitor the global partitioning information and dynamically modify the original partitioning function according to the data skew model, so the Partitioner can change the index of these partitioning which will cause data skew to the other reducer that has less load in the next partitioning process, and can eventually balance the load of each node. Finally, we experimentally compare our method with existing methods on both synthetic and real datasets, the experimental results show our strategy can solve the problem of data skew with better stability and efficiency than Hash method and Sampling method for non-connectivity MapReduce task.

  9. Nonlinear control for core power of pressurized water nuclear reactors using constant axial offset strategy

    Directory of Open Access Journals (Sweden)

    Gholam Reza Ansarifar

    2015-12-01

    Full Text Available One of the most important operations in nuclear power plants is load following, in which an imbalance of axial power distribution induces xenon oscillations. These oscillations must be maintained within acceptable limits otherwise the nuclear power plant could become unstable. Therefore, bounded xenon oscillation is considered to be a constraint for the load following operation. In this paper, the design of a sliding mode control (SMC, which is a robust nonlinear controller, is presented. SMC is a means to control pressurized water nuclear reactor (PWR power for the load following operation problem in a way that ensures xenon oscillations are kept bounded within acceptable limits. The proposed controller uses constant axial offset (AO strategy to ensure xenon oscillations remain bounded. The constant AO is a robust state constraint for the load following problem. The reactor core is simulated based on the two-point nuclear reactor model with a three delayed neutron groups. The stability analysis is given by means of the Lyapunov approach, thus the control system is guaranteed to be stable within a large range. The employed method is easy to implement in practical applications and moreover, the SMC exhibits the desired dynamic properties during the entire output-tracking process independent of perturbations. Simulation results are presented to demonstrate the effectiveness of the proposed controller in terms of performance, robustness, and stability. Results show that the proposed controller for the load following operation is so effective that the xenon oscillations are kept bounded in the given region.

  10. Improving the Quality of Online Discussion: The Effects of Strategies Designed Based on Cognitive Load Theory Principles

    Science.gov (United States)

    Darabi, Aubteen; Jin, Li

    2013-01-01

    This article focuses on heavy cognitive load as the reason for the lack of quality associated with conventional online discussion. Using the principles of cognitive load theory, four online discussion strategies were designed specifically aiming at reducing the discussants' cognitive load and thus enhancing the quality of their online discussion.…

  11. Effects of running with backpack loads during simulated gravitational transitions: Improvements in postural control

    Science.gov (United States)

    Brewer, Jeffrey David

    The National Aeronautics and Space Administration is planning for long-duration manned missions to the Moon and Mars. For feasible long-duration space travel, improvements in exercise countermeasures are necessary to maintain cardiovascular fitness, bone mass throughout the body and the ability to perform coordinated movements in a constant gravitational environment that is six orders of magnitude higher than the "near weightlessness" condition experienced during transit to and/or orbit of the Moon, Mars, and Earth. In such gravitational transitions feedback and feedforward postural control strategies must be recalibrated to ensure optimal locomotion performance. In order to investigate methods of improving postural control adaptation during these gravitational transitions, a treadmill based precision stepping task was developed to reveal changes in neuromuscular control of locomotion following both simulated partial gravity exposure and post-simulation exercise countermeasures designed to speed lower extremity impedance adjustment mechanisms. The exercise countermeasures included a short period of running with or without backpack loads immediately after partial gravity running. A novel suspension type partial gravity simulator incorporating spring balancers and a motor-driven treadmill was developed to facilitate body weight off loading and various gait patterns in both simulated partial and full gravitational environments. Studies have provided evidence that suggests: the environmental simulator constructed for this thesis effort does induce locomotor adaptations following partial gravity running; the precision stepping task may be a helpful test for illuminating these adaptations; and musculoskeletal loading in the form of running with or without backpack loads may improve the locomotor adaptation process.

  12. Learning and Control Model of the Arm for Loading

    Science.gov (United States)

    Kim, Kyoungsik; Kambara, Hiroyuki; Shin, Duk; Koike, Yasuharu

    We propose a learning and control model of the arm for a loading task in which an object is loaded onto one hand with the other hand, in the sagittal plane. Postural control during object interactions provides important points to motor control theories in terms of how humans handle dynamics changes and use the information of prediction and sensory feedback. For the learning and control model, we coupled a feedback-error-learning scheme with an Actor-Critic method used as a feedback controller. To overcome sensory delays, a feedforward dynamics model (FDM) was used in the sensory feedback path. We tested the proposed model in simulation using a two-joint arm with six muscles, each with time delays in muscle force generation. By applying the proposed model to the loading task, we showed that motor commands started increasing, before an object was loaded on, to stabilize arm posture. We also found that the FDM contributes to the stabilization by predicting how the hand changes based on contexts of the object and efferent signals. For comparison with other computational models, we present the simulation results of a minimum-variance model.

  13. On the modelling and partial-load control of variable-speed wind turbines

    Energy Technology Data Exchange (ETDEWEB)

    Novak, P [Chalmers Univ. of Technology, Goeteborg (Sweden). School of Electrical and Computer Engineering

    1996-12-31

    The focus of this thesis is on modelling and variable-speed control of wind turbines. A physical model structure including the fundamental drive-train mode is derived and validated by system-identification experiments on a full-scale wind turbine. The resulting, parametrized model has been used as a basis for an evaluation of controllers for partial-load operation, validated by non-linear simulations. This evaluation, including several controller concepts, verifies that a sophisticated controller becomes necessary, when stretching the limits in power-loss minimization. This control strategy also demands the sampling frequency to be pushed to a high level. As a consequence, the angular-position measurements become time correlated and, in the limit, periodic. It is shown in the thesis how the resulting, operating-point-dependent effects on the measurement errors influence the estimation quality, using a stationary Kalman filter as an example. A gain-scheduling estimation approach is shown to improve the performance. 39 refs, 63 figs, 2 tabs

  14. Control, Co-generation, and Sensor Placement Strategy for Integral Small Modular Reactors

    International Nuclear Information System (INIS)

    Upadhyaya, Belle-R.; Fan, Li; Hines, J.-Wesley; Perillo, Sergio-R. P.

    2011-01-01

    The development of Small Modular Reactors (SMR) has multiple applications for electricity generation, process heat, hydrogen production, and others. The results of research, development, and demonstration (RD and D) of load-following control design for multiple modules, nuclear desalination, and sensor placement strategy for enhanced fault detection and isolation, are presented in this paper. The technologies are demonstrated with application to an integral pressurized water reactor (IPWR) such as the IRIS reactor. The outcomes of this RD and D include the development of a complete dynamic model of the IRIS system, load following control under dual-module steam mixing, nuclear desalination with a multi-stage flash (MSF) desalination plant, and automated technique for sensor allocation in a combined reactor and balance-of-plant system. The dynamic performance of a nuclear power station comprised of two IRIS reactor modules, operating simultaneously with a common steam header with steam mixing, was evaluated. The control problem addressed 'load-following' scenarios, such as varying load during the day or reduced consumption during the weekend. To solve this problem, a single-module IRIS MATLAB-Simulink model was developed and used to quantify the responses from both modules. The resulting model was subjected to eight different perturbation cases to analyze its capability of detecting small perturbations, therefore testing its robustness and sensitivity. The prospects of using nuclear energy for seawater desalination on a large scale can be very attractive since desalination is an energy intensive process that can utilize the heat from a nuclear reactor and/or the electricity produced by such plants. Small modular reactors, ranging from 50 MWe to 300 MWe, offer the largest potential as coupling options to nuclear desalination systems. However, coupling a nuclear plant and a desalination plant involves a number of issues that have to be addressed. Among these issues

  15. Control, Co-generation, and Sensor Placement Strategy for Integral Small Modular Reactors

    Energy Technology Data Exchange (ETDEWEB)

    Upadhyaya, Belle-R.; Fan, Li; Hines, J.-Wesley [University of Tennessee, Knoxville (United States); Perillo, Sergio-R. P. [Instituto de Pesquisas Energeticas e Nucleares, Sao Paulo (Brazil)

    2011-08-15

    The development of Small Modular Reactors (SMR) has multiple applications for electricity generation, process heat, hydrogen production, and others. The results of research, development, and demonstration (RD and D) of load-following control design for multiple modules, nuclear desalination, and sensor placement strategy for enhanced fault detection and isolation, are presented in this paper. The technologies are demonstrated with application to an integral pressurized water reactor (IPWR) such as the IRIS reactor. The outcomes of this RD and D include the development of a complete dynamic model of the IRIS system, load following control under dual-module steam mixing, nuclear desalination with a multi-stage flash (MSF) desalination plant, and automated technique for sensor allocation in a combined reactor and balance-of-plant system. The dynamic performance of a nuclear power station comprised of two IRIS reactor modules, operating simultaneously with a common steam header with steam mixing, was evaluated. The control problem addressed 'load-following' scenarios, such as varying load during the day or reduced consumption during the weekend. To solve this problem, a single-module IRIS MATLAB-Simulink model was developed and used to quantify the responses from both modules. The resulting model was subjected to eight different perturbation cases to analyze its capability of detecting small perturbations, therefore testing its robustness and sensitivity. The prospects of using nuclear energy for seawater desalination on a large scale can be very attractive since desalination is an energy intensive process that can utilize the heat from a nuclear reactor and/or the electricity produced by such plants. Small modular reactors, ranging from 50 MWe to 300 MWe, offer the largest potential as coupling options to nuclear desalination systems. However, coupling a nuclear plant and a desalination plant involves a number of issues that have to be addressed. Among these

  16. Simulation of load traffic and steeped speed control of conveyor

    Science.gov (United States)

    Reutov, A. A.

    2017-10-01

    The article examines the possibilities of the step control simulation of conveyor speed within Mathcad, Simulink, Stateflow software. To check the efficiency of the control algorithms and to more accurately determine the characteristics of the control system, it is necessary to simulate the process of speed control with real values of traffic for a work shift or for a day. For evaluating the belt workload and absence of spillage it is necessary to use empirical values of load flow in a shorter period of time. The analytical formulas for optimal speed step values were received using empirical values of load. The simulation checks acceptability of an algorithm, determines optimal parameters of regulation corresponding to load flow characteristics. The average speed and the number of speed switching during simulation are admitted as criteria of regulation efficiency. The simulation example within Mathcad software is implemented. The average conveyor speed decreases essentially by two-step and three-step control. A further increase in the number of regulatory steps decreases average speed insignificantly but considerably increases the intensity of the speed switching. Incremental algorithm of speed regulation uses different number of stages for growing and reducing load traffic. This algorithm allows smooth control of the conveyor speed changes with monotonic variation of the load flow. The load flow oscillation leads to an unjustified increase or decrease of speed. Work results can be applied at the design of belt conveyors with adjustable drives.

  17. Mitigating the Long term Operating Extreme Load through Active Control

    DEFF Research Database (Denmark)

    Koukoura, Christina; Natarajan, Anand

    2014-01-01

    blade azimuth location are shown to affect the extreme blade load magnitude during operation in normal turbulence wind input. The simultaneously controlled operation of generator torque variation and pitch variation at low blade pitch angles is detected to be responsible for very high loads acting...... on the blades. Through gain scheduling of the controller (modifications of the proportional Kp and the integral Ki gains) the extreme loads are mitigated, ensuring minimum instantaneous variations in the power production for operation above rated wind speed. The response of the blade load is examined...

  18. Study on load temperature control system of ground laser communication

    Science.gov (United States)

    Zhai, Xunhua; Zhang, Hongtao; Liu, Wangsheng; Zhang, Chijun; Zhou, Xun

    2007-12-01

    The ground laser communication terminal as the termination of a communication system, works at the temperature which varies from -40°C to 50°C. We design a temperature control system to keep optical and electronic components working properly in the load. The load is divided into two sections to control temperature respectively. Because the space is limited, we use heater film and thermoelectric cooler to clearify and refrigerate the load. We design a hardware and a software for the temperature control system, establish mathematic model, and emulate it with Matlab.

  19. The effects of emission control strategies on light-absorbing carbon emissions from a modern heavy-duty diesel engine.

    Science.gov (United States)

    Robinson, Michael A; Olson, Michael R; Liu, Z Gerald; Schauer, James J

    2015-06-01

    Control of atmospheric black carbon (BC) and brown carbon (BrC) has been proposed as an important pathway to climate change mitigation, but sources of BC and BrC are still not well understood. In order to better identify the role of modern heavy-duty diesel engines on the production of BC and BrC, emissions from a heavy-duty diesel engine operating with different emission control strategies were examined using a source dilution sampling system. The effect of a diesel oxidation catalyst (DOC) and diesel particulate filter (DPF) on light-absorbing carbon (LAC) was evaluated at three steady-state engine operation modes: idle, 50% speed and load, and 100% speed and load. LAC was measured with four different engine configurations: engine out, DOC out, DPF out, and engine out with an altered combustion calibration. BC and BrC emission rates were measured with the Aethalometer (AE-31). EC and BC emission rates normalized to the mass of CO₂emitted increased with increasing engine speed and load. Emission rates normalized to brake-specific work did not exhibit similar trends with speed and load, but rather the highest emission rate was measured at idle. EC and OC emissions were reduced by 99% when the DOC and DPF architecture was applied. The application of a DPF was equally effective at removing 99% of the BC fraction of PM, proving to be an important control strategy for both LAC and PM. BC emissions were unexpectedly increased across the DOC, seemingly due to a change aerosol optical properties. Removal of exhaust gas recirculation (EGR) flow due to simulated EGR cooler failure caused a large increase in OC and BrC emission rates at idle, but had limited influence during high load operation. LAC emissions proved to be sensitive to the same control strategies effective at controlling the total mass of diesel PM. In the context of black carbon emissions, very small emission rates of brown carbon were measured over a range of control technologies and engine operating

  20. Predictive Solar-Integrated Commercial Building Load Control

    Energy Technology Data Exchange (ETDEWEB)

    Glasgow, Nathan [EdgePower Inc., Aspen, CO (United States)

    2017-01-31

    This report is the final technical report for the Department of Energy SunShot award number EE0007180 to EdgePower Inc., for the project entitled “Predictive Solar-Integrated Commercial Building Load Control.” The goal of this project was to successfully prove that the integration of solar forecasting and building load control can reduce demand charge costs for commercial building owners with solar PV. This proof of concept Tier 0 project demonstrated its value through a pilot project at a commercial building. This final report contains a summary of the work completed through he duration of the project. Clean Power Research was a sub-recipient on the award.

  1. Loads as a Resource: Frequency Responsive Demand

    Energy Technology Data Exchange (ETDEWEB)

    Kalsi, Karanjit [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Lian, Jianming [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Marinovici, Laurentiu D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Elizondo, Marcelo A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zhang, Wei [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Moya, Christian [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2014-10-08

    Frequency control plays an important role in preserving the power balance of a multi-machine power system. Generators modify their power output when a non-zero frequency deviation is presented in order to restore power balance across the network. However, with plans for large-scale penetration of renewable energy resources, performing primary frequency control using only supply-side resources becomes not only prohibitively expensive, but also technically difficult. Frequency control from the demand side or load control presents a novel and viable way for providing the desired frequency response. Loads can measure frequency locally and change their power consumption after a non-zero frequency deviation is presented in order to achieve power balance between generation and consumption. The specific objectives of this project are to: •Provide a framework to facilitate large-scale deployment of frequency responsive end-use devices •Systematically design decentralized frequency-based load control strategies for enhanced stability performance •Ensure applicability over wide range of operating conditions while accounting for unpredictable end-use behavior and physical device constraints •Test and validate control strategy using large-scale simulations and field demonstrations •Create a level-playing field for smart grid assets with conventional generators

  2. Evaluation of SMART load follow operation capability

    International Nuclear Information System (INIS)

    Song, Jae Seung; Zee, Sung Quun

    1998-07-01

    The daily load follow operation capability of SMART, which is 330 MWth integral reactor with boron free operation concept, was evaluated. In the boron free operation core the axial offset(AO) can not be limited or limited by wider range than the typical PWR that uses soluble boron. Current SMART conceptual core design does not have the limit for the axial offset and the operation is limited by three dimensional local power peak. In this report, the capability of load follow operation is evaluated for 14-2-6-2 daily load follow by 50% power reduction that is very typical in the large commercial power reactors. The cycle length of SMART is limited by three dimensional local power peak and the nominal axial power distribution is top skewed at the end of cycle. When the power returns to 100%, control rod should be withdrawn for the compensation of reactivity decrease due to the xenon buildup. The control rod withdrawal results in the increase of three dimensional local power peak. To solve this problem, an operation strategy for the control of local peak. To solve this problem, an operation strategy for the control of local peak was established and it was shown that the strategy is effective in controlling the local peak less than target value of the three dimensional local power peak. (author). 7 refs., 5 tabs., 13 figs

  3. Provision of Supplementary Load Frequency Control via Aggregation of Air Conditioning Loads

    Directory of Open Access Journals (Sweden)

    Lei Zhou

    2015-12-01

    Full Text Available The integration of large-scale renewable energy poses great challenges for the operation of power system because of its increased frequency fluctuations. More load frequency control (LFC resources are demanded in order to maintain a stable system with more renewable energy injected. Unlike the costly LFC resources on generation side, the thermostatically controlled loads (TCLs on the demand side become an attractive solution on account of its substantial quantities and heat-storage capacity. It generally contains air conditioners (ACs, water heaters and fridges. In this paper, the supplementary LFC is extracted by the modeling and controlling of aggregated ACs. We first present a control framework integrating the supplementary LFC with the traditional LFC. Then, a change-time-priority-list method is proposed to control power output taking into account customers’ satisfaction. Simulations on a single-area power system with wind power integration demonstrate the effectiveness of the proposed method. The impact of ambient temperature changes and customer preferences on room temperature is also involved in the discussion. Results show that the supplementary LFC provided by ACs could closely track the LFC signals and effectively reduce the frequency deviation.

  4. Control strategies for demand controlled ventilation in dwellings

    DEFF Research Database (Denmark)

    Nielsen, Toke Rammer; Drivsholm, Christian

    2011-01-01

    and efficient fans is becoming the standard solution. The building regulation requirement for air change in dwellings is often a constant value that has been chosen to avoid moisture related problems in the indoor environment. This required air change is sometimes sufficient, sometimes too low and sometimes too....... In the studied house two control strategies were tested. A simple strategy where all sensors and controls were located in the air handling unit and only the speed of the fans can be controlled, and a complex strategy where sensors were placed in each room and where individual control of air flow in each room...

  5. Improved Load Frequency Control Using a Fast Acting Active Disturbance Rejection Controller

    Directory of Open Access Journals (Sweden)

    Md Mijanur Rahman

    2017-10-01

    Full Text Available System frequency may change from defined values while transmitting power from one area to another in an interconnected power system due to various reasons such as load changes and faults. This frequency change causes a frequency error in the system. However, the system frequency should always be maintained close to the nominal value even in the presence of model uncertainties and physical constraints. This paper proposes an Active Disturbance Rejection Controller (ADRC-based load frequency control (LFC of an interconnected power system. The controller incorporates effects of generator inertia and generator electrical proximity to the point of disturbances. The proposed controller reduces the magnitude error of the area control error (ACE of an interconnected power system compared to the standard controller. The simulation results verify the effectiveness of proposed ADRC in the application of LFC of an interconnected power system.

  6. Performance evaluation of a full-scale advanced phase isolation ditch process by using real-time control strategies

    International Nuclear Information System (INIS)

    Kim, Hyosoo; Kim, Yejin; Kim, Minsoo; Piao, Wenhua; Kim, Changwon; Gee, Jeasung

    2014-01-01

    This paper proposes real-time control strategies that can be applied in a full-scale advanced phase isolation ditch (APID) process. Real-time operation mode control (OMC) and aeration section control (ASC) strategies were developed to cope more stably with fluctuations in the influent loading and to increase the nitrification and denitrification reactions within the entire volume. The real-time OMC and ASC strategies were evaluated using mathematical models. When the NH 4 -N in the reactor was maintained at a high level, appropriate control actions, such as continuing the aeration state, stopping the influent inflow and increasing the aeration section, were applied in the APID process. In contrast, when the NO X -N in the reactor was maintained at a high level, the non-aeration state, influent inflow, and decreased aeration section were continued. It was concluded that stable operation in the APID process could be achieved by applying real-time OMC and ASC strategies developed in this study

  7. Performance evaluation of a full-scale advanced phase isolation ditch process by using real-time control strategies

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyosoo; Kim, Yejin; Kim, Minsoo; Piao, Wenhua; Kim, Changwon [Pusan National University, Busan (Korea, Republic of); Gee, Jeasung [Taiwha Industrial Co. Ltd., Seoul (Korea, Republic of)

    2014-04-15

    This paper proposes real-time control strategies that can be applied in a full-scale advanced phase isolation ditch (APID) process. Real-time operation mode control (OMC) and aeration section control (ASC) strategies were developed to cope more stably with fluctuations in the influent loading and to increase the nitrification and denitrification reactions within the entire volume. The real-time OMC and ASC strategies were evaluated using mathematical models. When the NH{sub 4}-N in the reactor was maintained at a high level, appropriate control actions, such as continuing the aeration state, stopping the influent inflow and increasing the aeration section, were applied in the APID process. In contrast, when the NO{sub X}-N in the reactor was maintained at a high level, the non-aeration state, influent inflow, and decreased aeration section were continued. It was concluded that stable operation in the APID process could be achieved by applying real-time OMC and ASC strategies developed in this study.

  8. Mitigating the Long term Operating Extreme Load through Active Control

    International Nuclear Information System (INIS)

    Koukoura, Christina; Natarajan, Anand

    2014-01-01

    The parameters influencing the long term extreme operating design loads are identified through the implementation of a Design of Experiment (DOE) method. A function between the identified critical factors and the ultimate out-of-plane loads on the blade is determined. Variations in the initial blade azimuth location are shown to affect the extreme blade load magnitude during operation in normal turbulence wind input. The simultaneously controlled operation of generator torque variation and pitch variation at low blade pitch angles is detected to be responsible for very high loads acting on the blades. Through gain scheduling of the controller (modifications of the proportional Kp and the integral K gains) the extreme loads are mitigated, ensuring minimum instantaneous variations in the power production for operation above rated wind speed. The response of the blade load is examined for different values of the integral gain as resulting in rotor speed error and the rate of change of rotor speed. Based on the results a new load case for the simulation of extreme loads during normal operation is also presented

  9. An Optimized Control for LLC Resonant Converter with Wide Load Range

    Science.gov (United States)

    Xi, Xia; Qian, Qinsong

    2017-05-01

    This paper presents an optimized control which makes LLC resonant converters operate with a wider load range and provides good closed-loop performance. The proposed control employs two paralleled digital compensations to guarantee the good closed-loop performance in a wide load range during the steady state, an optimized trajectory control will take over to change the gate-driving signals immediately at the load transients. Finally, the proposed control has been implemented and tested on a 150W 200kHz 400V/24V LLC resonant converter and the result validates the proposed method.

  10. Automatic Power Control for Daily Load-following Operation using Model Predictive Control Method

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Keuk Jong; Kim, Han Gon [KH, Daejeon (Korea, Republic of)

    2009-10-15

    Under the circumstances that nuclear power occupies more than 50%, nuclear power plants are required to be operated on load-following operation in order to make the effective management of electric grid system and enhanced responsiveness to rapid changes in power demand. Conventional reactors such as the OPR1000 and APR1400 have a regulating system that controls the average temperature of the reactor core relation to the reference temperature. This conventional method has the advantages of proven technology and ease of implementation. However, this method is unsuitable for controlling the axial power shape, particularly the load following operation. Accordingly, this paper reports on the development of a model predictive control method which is able to control the reactor power and the axial shape index. The purpose of this study is to analyze the behavior of nuclear reactor power and the axial power shape by using a model predictive control method when the power is increased and decreased for a daily load following operation. The study confirms that deviations in the axial shape index (ASI) are within the operating limit.

  11. Intelligent electrical outlet for collective load control

    Science.gov (United States)

    Lentine, Anthony L.; Ford, Justin R.; Spires, Shannon V.; Goldsmith, Steven Y.

    2015-10-27

    Various technologies described herein pertain to an electrical outlet that autonomously manages loads in a microgrid. The electrical outlet can provide autonomous load control in response to variations in electrical power generation supply in the microgrid. The electrical outlet includes a receptacle, a sensor operably coupled to the receptacle, and an actuator configured to selectively actuate the receptacle. The sensor measures electrical parameters at the receptacle. Further, a processor autonomously controls the actuator based at least in part on the electrical parameters measured at the receptacle, electrical parameters from one or more disparate electrical outlets in the microgrid, and a supply of generated electric power in the microgrid at a given time.

  12. Structural Load Analysis of a Wind Turbine under Pitch Actuator and Controller Faults

    International Nuclear Information System (INIS)

    Etemaddar, Mahmoud; Gao, Zhen; Moan, Torgeir

    2014-01-01

    In this paper, we investigate the characteristics of a wind turbine under blade pitch angle and shaft speed sensor faults as well as pitch actuator faults. A land-based NREL 5MW variable speed pitch reg- ulated wind turbine is considered as a reference. The conventional collective blade pitch angle controller strategy with independent pitch actuators control is used for load reduction. The wind turbine class is IEC-BII. The main purpose is to investigate the severity of end effects on structural loads and responses and consequently identify the high-risk components according to the type and amplitude of fault using a servo-aero-elastic simulation code, HAWC2. Both transient and steady state effects of faults are studied. Such information is useful for wind turbine fault detection and identification as well as system reliability analysis. Results show the effects of faults on wind turbine power output and responses. Pitch sensor faults mainly affects the vibration of shaft main bearing, while generator power and aerodynamic thrust are not changed significantly, due to independent pitch actuator control of three blades. Shaft speed sensor faults can seriously affect the generator power and aerodynamic thrust. Pitch actuator faults can result in fully pitching of the blade, and consequently rotor stops due to negative aerodynamic torque

  13. Identification of control and management strategies for LV unbalanced microgrids with plugged-in electric vehicles

    Energy Technology Data Exchange (ETDEWEB)

    Pecas Lopes, J.A.; Moreira, C.L. [INESC Porto, Faculdade de Engenharia da Universidade do Porto, Campus da FEUP, Rua Dr. Roberto Frias 378, 4200-465 Porto (Portugal); Polenz, Silvan A.; Cherkaoui, Rachid [EPFL - Ecole Polytechnique Federale de Lausanne, Laboratoire des Reseaux Electriques, Lausanne (Switzerland)

    2010-08-15

    This paper addresses issues concerning the integration of single-phase charging devices for electric vehicles (EV) in low-voltage microgrids. Fast release energy storage is a key issue for microgrid islanding operation. EV batteries provide an additional storage capacity, which can now be exploited in order to improve MG islanding. Aiming to do so, different control strategies were developed and tested: (1) a local control approach where no communication link is required and (2) a centralized charging control solution. The local control approach is based on the measuring of EV terminal voltage and frequency in order to define the charging or discharging rates of the batteries. The centralized control strategy allows balancing single-phase loads connected to the microgrid by adapting the charging rates of the EV storage devices. Simulation results show that EV batteries can actively contribute for voltage balancing and frequency control during islanding operating conditions. (author)

  14. Load-Dependent Interference of Deep Brain Stimulation of the Subthalamic Nucleus with Switching from Automatic to Controlled Processing During Random Number Generation in Parkinson's Disease.

    Science.gov (United States)

    Williams, Isobel Anne; Wilkinson, Leonora; Limousin, Patricia; Jahanshahi, Marjan

    2015-01-01

    Deep brain stimulation of the subthalamic nucleus (STN DBS) ameliorates the motor symptoms of Parkinson's disease (PD). However, some aspects of executive control are impaired with STN DBS. We tested the prediction that (i) STN DBS interferes with switching from automatic to controlled processing during fast-paced random number generation (RNG) (ii) STN DBS-induced cognitive control changes are load-dependent. Fifteen PD patients with bilateral STN DBS performed paced-RNG, under three levels of cognitive load synchronised with a pacing stimulus presented at 1, 0.5 and 0.33 Hz (faster rates require greater cognitive control), with DBS on or off. Measures of output randomness were calculated. Countscore 1 (CS1) indicates habitual counting in steps of one (CS1). Countscore 2 (CS2) indicates a more controlled strategy of counting in twos. The fastest rate was associated with an increased CS1 score with STN DBS on compared to off. At the slowest rate, patients had higher CS2 scores with DBS off than on, such that the differences between CS1 and CS2 scores disappeared. We provide evidence for a load-dependent effect of STN DBS on paced RNG in PD. Patients could switch to more controlled RNG strategies during conditions of low cognitive load at slower rates only when the STN stimulators were off, but when STN stimulation was on, they engaged in more automatic habitual counting under increased cognitive load. These findings are consistent with the proposal that the STN implements a switch signal from the medial frontal cortex which enables a shift from automatic to controlled processing.

  15. Physical load handling and listening comprehension effects on balance control.

    Science.gov (United States)

    Qu, Xingda

    2010-12-01

    The purpose of this study was to determine the physical load handling and listening comprehension effects on balance control. A total of 16 young and 16 elderly participants were recruited in this study. The physical load handling task required holding a 5-kg load in each hand with arms at sides. The listening comprehension task involved attentive listening to a short conversation. Three short questions were asked regarding the conversation right after the testing trial to test the participants' attentiveness during the experiment. Balance control was assessed by centre of pressure-based measures, which were calculated from the force platform data when the participants were quietly standing upright on a force platform. Results from this study showed that both physical load handling and listening comprehension adversely affected balance control. Physical load handling had a more deleterious effect on balance control under the listening comprehension condition vs. no-listening comprehension condition. Based on the findings from this study, interventions for the improvement of balance could be focused on avoiding exposures to physically demanding tasks and cognitively demanding tasks simultaneously. STATEMENT OF RELEVANCE: Findings from this study can aid in better understanding how humans maintain balance, especially when physical and cognitive loads are applied. Such information is useful for developing interventions to prevent fall incidents and injuries in occupational settings and daily activities.

  16. A modeling and control approach to advanced nuclear power plants with gas turbines

    International Nuclear Information System (INIS)

    Ablay, Günyaz

    2013-01-01

    Highlights: • Load frequency control strategies in nuclear plants are researched. • Nuclear reactor-centered control system may not be suitable for load control. • Local unit controllers improve stability and overall time constant. • Coolant loops in nuclear plants should be controlled locally. - Abstract: Advanced nuclear power plants are currently being proposed with a number of various designs. However, there is a lack of modeling and control strategies to deal with load following operations. This research investigates a possible modeling approach and load following control strategy for gas turbine nuclear power plants in order to provide an assessment way to the concept designs. A load frequency control strategy and average temperature control mechanism are studied to get load following nuclear power plants. The suitability of the control strategies and concept designs are assessed through linear stability analysis methods. Numerical results are presented on an advanced molten salt reactor concept as an example nuclear power plant system to demonstrate the validity and effectiveness of the proposed modeling and load following control strategies

  17. A Review of Transformer Aging and Control Strategies

    Energy Technology Data Exchange (ETDEWEB)

    Gourisetti, Sri Nikhil Gup; Kirkham, Harold; Sivaraman, Deepak

    2017-09-19

    Transformer aging is an important challenge in power system. Distribution transformers themselves are minimally controllable, but smart meters provide excellent, new insights into electrical loads, which insights can be used to understand and mitigate transformer aging. The nature of transformer loads is changing with the integration of distributed energy resources (DERs) and electric vehicles (EVs). This paper first reviews factors that influence the aging of distribution transformers, including root causes of transformer failure. Existing and proposed load control methods are then discussed. A distribution model is introduced to help evaluate potential control methods.

  18. Wireless power charging using point of load controlled high frequency power converters

    Science.gov (United States)

    Miller, John M.; Campbell, Steven L.; Chambon, Paul H.; Seiber, Larry E.; White, Clifford P.

    2015-10-13

    An apparatus for wirelessly charging a battery of an electric vehicle is provided with a point of load control. The apparatus includes a base unit for generating a direct current (DC) voltage. The base unit is regulated by a power level controller. One or more point of load converters can be connected to the base unit by a conductor, with each point of load converter comprising a control signal generator that transmits a signal to the power level controller. The output power level of the DC voltage provided by the base unit is controlled by power level controller such that the power level is sufficient to power all active load converters when commanded to do so by any of the active controllers, without generating excessive power that may be otherwise wasted.

  19. A new islanding detection technique for multiple mini hydro based on rate of change of reactive power and load connecting strategy

    International Nuclear Information System (INIS)

    Laghari, J.A.; Mokhlis, H.; Bakar, A.H.A.; Karimi, M.

    2013-01-01

    Highlights: • The requirement of DG interconnection with existing power system is discussed. • Various islanding detection techniques are discussed with their merits and demerits. • New islanding detection strategy is proposed for multiple mini hydro type DGs. • The proposed strategy is based on dq/dt and load connecting strategy. • The effectiveness of strategy is verified on various other cases. - Abstract: The interconnection of distributed generation (DG) into distribution networks is undergoing a rapid global expansion. It enhances the system’s reliability, while simultaneously reduces pollution problems related to the generation of electrical power. To fully utilize the benefits of DGs, certain technical issues need to be addressed. One of the most important issues in this context is islanding detection. This paper presents a new islanding detection technique that is suitable for multiple mini-hydro type DG units. The proposed strategy is based on the rate of change of reactive power and load connecting strategy to detect islanding within the system. For a large power mismatch, islanding is detected by rate of change of reactive power only. However, for a close power mismatch, the rate of change of reactive power initiates a load connecting strategy, which in turn alters the load on the distribution network. This load variation in the distribution network causes a variation in the rate of change of reactive power, which is utilized to distinguish islanding and other events. The simulation results show that the proposed strategy is effective in detecting islanding occurrence in a distribution network

  20. Automatic control of load increases power and efficiency in a microbial fuel cell

    Energy Technology Data Exchange (ETDEWEB)

    Premier, Giuliano C.; Kim, Jung Rae; Michie, Iain [Sustainable Environment Research Centre (SERC), Faculty of Advanced Technology, University of Glamorgan, Pontypridd, Mid-Glamorgan CF37 1DL (United Kingdom); Dinsdale, Richard M.; Guwy, Alan J. [Sustainable Environment Research Centre (SERC), Faculty of Health, Sport and Science, University of Glamorgan, Pontypridd, Mid-Glamorgan CF37 1DL (United Kingdom)

    2011-02-15

    Increasing power production and coulombic efficiency (CE) of microbial fuel cells (MFCs) is a common research ambition as the viability of the technology depends to some extent on these measures of performance. As MFCs are typically time varying systems, comparative studies of controlled and un-controlled external load impedance are needed to show if control affects the biocatalyst development and hence MFC performance. The application of logic based control of external load resistance is shown to increase the power generated by the MFC, when compared to an equivalent system which has a static resistive load. The controlled MFC generated 1600 {+-} 400 C, compared to 300 {+-} 10 C with an otherwise replicate fixed load MFC system. The use of a parsimonious gradient based control was able to increase the CE to within the range of 15.1-22.7%, while the CE for a 200 {omega} statically loaded MFC lay in the range 3.3-3.7%. The controlled MFC improves the electrogenic anodic biofilm selection for power production, indicating that greater power and substrate conversion can be achieved by controlling load impedance. Load control ensured sustainable current demand, applied microbial selection pressures and provided near-optimal impedance for power transference, compared to the un-controlled system. (author)

  1. Enhanced Load Power Sharing Accuracy in Droop-Controlled DC Microgrids with Both Mesh and Radial Configurations

    Directory of Open Access Journals (Sweden)

    Yiqi Liu

    2015-04-01

    Full Text Available The rational power sharing among different interface converters should be determined by the converter capacity. In order to guarantee that each converter operates at the ideal condition, considering the radial and mesh configuration, a modified strategy for load power sharing accuracy enhancement in droop-controlled DC microgrid is proposed in this paper. Two compensating terms which include averaging output power control and averaging DC voltage control of neighboring converters are employed. Since only the information of the neighboring converter is used, the complexity of the communication network can be reduced. The rational distribution of load power for different line resistance conditions is realized by using modified droop control that can be regarded as a distributed approach. Low bandwidth communication is used for exchanging sampled information between different converters. The feasibility and effectiveness of the proposed method for different network configurations and line resistances under different communication delay is analyzed in detail. Simulation results derived from a DC microgrid with three converters is implemented in MATLAB/Simulink to verify the proposed approach. Experimental results from a 3 × 10 kW prototype also show the performance of the proposed modified droop control scheme.

  2. Load mitigation of unbalanced wind turbines using PI-R individual pitch control

    DEFF Research Database (Denmark)

    Zhang, Yunqian; Cheng, Ming; Chen, Zhe

    2015-01-01

    This study discusses the load mitigation of unbalanced wind turbines, including balanced and unbalanced loads. Regarding the wind turbine load reduction, it has been shown that individual pitch control (IPC) is more promising in comparison with collective pitch control. However, wind turbine......) controller and two resonant (R) compensators is presented. The PI-R regulator is implemented in the hub reference frame to reduce both the balanced and unbalanced loads of the turbine. The wind turbine code FAST (fatigue, aerodynamics, structures and turbulence) is used for the wind turbine load modelling....... The simulations are conducted on the NREL upwind 1.5 MW wind turbine model. Elimination of both the balanced and unbalanced loads of the wind turbine has been achieved, so that PI-R IPC is demonstrated as an effective means for load mitigation of unbalanced wind turbines....

  3. Constrained model predictive control for load-following operation of APR reactors

    International Nuclear Information System (INIS)

    Kim, Jae Hwan; Lee, Sim Won; Kim, Ju Hyun; Na, Man Gyun; Yu, Keuk Jong; Kim, Han Gon

    2012-01-01

    The load-following operation of APR+ reactor is needed to control the power effectively using the control rods and to restrain the reactivity control from using the boric acid for flexibility of plant operation. Usually, the reason why the disproportion of axial flux distribution occurs during load-following operation is xenon-induced oscillation. The xenon has a very high absorption cross-section and makes the impact on the reactor delayed by the iodine precursor. The power maneuvering using automatically load-following operation has advantage in terms of safety and economic operation of the reactor, so the controller has to be designed efficiently. Therefore, an advanced control method that meets the conditions such as automatic control, flexibility, safety, and convenience is necessary to load-following operation of APR+ reactor. In this paper, the constrained model predictive control (MPC) method is applied to design APR reactor's automatic load-following controller for the integrated thermal power level and axial shape index (ASI) control. Some controllers use only the current tracking command, but MPC considers future commands in addition to the current tracking command. So, MPC can achieve better tracking performance than others. Furthermore, an MPC is to used in many industrial process control systems. The basic concept of the MPC is to solve an optimization problem for a finite future time interval at present time and to implement the first optimal control input as the current control input. The KISPAC-1D code, which models the APR+ nuclear power plants, is interfaced to the proposed controller to verify the tracking performance of the reactor power level and ASI. It is known that the proposed controller exhibits very fast tracking responses

  4. Thermostat Controlled Loads Flexibility Assessment for Enabling Load Shifting – An Experimental Proof in a Low Voltage Grid

    DEFF Research Database (Denmark)

    Lakshmanan, Venkatachalam; Marinelli, Mattia; Kosek, Anna M.

    2017-01-01

    This paper investigates the usability of thermostat controlled domestic appliances for load shift in LV distribution grids. The proposed method uses refrigerators for the demonstration of adaptive load prediction to estimate its flexibility and perform scheduling based on load threshold limit. Tw...

  5. An intelligent nuclear reactor core controller for load following operations, using recurrent neural networks and fuzzy systems

    International Nuclear Information System (INIS)

    Boroushaki, M.; Ghofrani, M.B.; Lucas, C.; Yazdanpanah, M.J.

    2003-01-01

    In the last decade, the intelligent control community has paid great attention to the topic of intelligent control systems for nuclear plants (core, steam generator...). Papers mostly used approximate and simple mathematical SISO (single-input-single-output) model of nuclear plants for testing and/or tuning of the control systems. They also tried to generalize theses models to a real MIMO (multi-input-multi-output) plant, while nuclear plants are typically of complex nonlinear and multivariable nature with high interactions between their state variables and therefore, many of these proposed intelligent control systems are not appropriate for real cases. In this paper, we designed an on-line intelligent core controller for load following operations, based on a heuristic control algorithm, using a valid and updatable recurrent neural network (RNN). We have used an accurate 3-dimensional core calculation code to represent the real plant and to train the RNN. The results of simulation show that this intelligent controller can control the reactor core during load following operations, using optimum control rod groups manoeuvre and variable overlapping strategy. This methodology represents a simple and reliable procedure for controlling other complex nonlinear MIMO plants, and may improve the responses, comparing to other control systems

  6. Photovoltaic power converter system with a controller configured to actively compensate load harmonics

    Science.gov (United States)

    de Rooij, Michael Andrew; Steigerwald, Robert Louis; Delgado, Eladio Clemente

    2008-12-16

    Photovoltaic power converter system including a controller configured to reduce load harmonics is provided. The system comprises a photovoltaic array and an inverter electrically coupled to the array to generate an output current for energizing a load connected to the inverter and to a mains grid supply voltage. The system further comprises a controller including a first circuit coupled to receive a load current to measure a harmonic current in the load current. The controller includes a second circuit to generate a fundamental reference drawn by the load. The controller further includes a third circuit for combining the measured harmonic current and the fundamental reference to generate a command output signal for generating the output current for energizing the load connected to the inverter. The photovoltaic system may be configured to compensate harmonic currents that may be drawn by the load.

  7. Power system security enhancement through direct non-disruptive load control

    Science.gov (United States)

    Ramanathan, Badri Narayanan

    The transition to a competitive market structure raises significant concerns regarding reliability of the power grid. A need to build tools for security assessment that produce operating limit boundaries for both static and dynamic contingencies is recognized. Besides, an increase in overall uncertainty in operating conditions makes corrective actions at times ineffective leaving the system vulnerable to instability. The tools that are in place for stability enhancement are mostly corrective and suffer from lack of robustness to operating condition changes. They often pose serious coordination challenges. With deregulation, there have also been ownership and responsibility issues associated with stability controls. However, the changing utility business model and the developments in enabling technologies such as two-way communication, metering, and control open up several new possibilities for power system security enhancement. This research proposes preventive modulation of selected loads through direct control for power system security enhancement. Two main contributions of this research are the following: development of an analysis framework and two conceptually different analysis approaches for load modulation to enhance oscillatory stability, and the development and study of algorithms for real-time modulation of thermostatic loads. The underlying analysis framework is based on the Structured Singular Value (SSV or mu) theory. Based on the above framework, two fundamentally different approaches towards analysis of the amount of load modulation for desired stability performance have been developed. Both the approaches have been tested on two different test systems: CIGRE Nordic test system and an equivalent of the Western Electric Coordinating Council test system. This research also develops algorithms for real-time modulation of thermostatic loads that use the results of the analysis. In line with some recent load management programs executed by utilities, two

  8. A Novel Control Strategy for Autonomous Operation of Isolated Microgrid with Prioritized Loads

    Science.gov (United States)

    Kumar, R. Hari; Ushakumari, S.

    2018-05-01

    Maintenance of power balance between generation and demand is one of the most critical requirements for the stable operation of a power system network. To mitigate the power imbalance during the occurrence of any disturbance in the system, fast acting algorithms are inevitable. This paper proposes a novel algorithm for load shedding and network reconfiguration in an isolated microgrid with prioritized loads and multiple islands, which will help to quickly restore the system in the event of a fault. The performance of the proposed algorithm is enhanced using genetic algorithm and its effectiveness is illustrated with simulation results on modified Consortium for Electric Reliability Technology Solutions (CERTS) microgrid.

  9. Sensor-Based Optimized Control of the Full Load Instability in Large Hydraulic Turbines

    Directory of Open Access Journals (Sweden)

    Alexandre Presas

    2018-03-01

    Full Text Available Hydropower plants are of paramount importance for the integration of intermittent renewable energy sources in the power grid. In order to match the energy generated and consumed, Large hydraulic turbines have to work under off-design conditions, which may lead to dangerous unstable operating points involving the hydraulic, mechanical and electrical system. Under these conditions, the stability of the grid and the safety of the power plant itself can be compromised. For many Francis Turbines one of these critical points, that usually limits the maximum output power, is the full load instability. Therefore, these machines usually work far away from this unstable point, reducing the effective operating range of the unit. In order to extend the operating range of the machine, working closer to this point with a reasonable safety margin, it is of paramount importance to monitor and to control relevant parameters of the unit, which have to be obtained with an accurate sensor acquisition strategy. Within the framework of a large EU project, field tests in a large Francis Turbine located in Canada (rated power of 444 MW have been performed. Many different sensors were used to monitor several working parameters of the unit for all its operating range. Particularly for these tests, more than 80 signals, including ten type of different sensors and several operating signals that define the operating point of the unit, were simultaneously acquired. The present study, focuses on the optimization of the acquisition strategy, which includes type, number, location, acquisition frequency of the sensors and corresponding signal analysis to detect the full load instability and to prevent the unit from reaching this point. A systematic approach to determine this strategy has been followed. It has been found that some indicators obtained with different types of sensors are linearly correlated with the oscillating power. The optimized strategy has been determined

  10. Sensor-Based Optimized Control of the Full Load Instability in Large Hydraulic Turbines.

    Science.gov (United States)

    Presas, Alexandre; Valentin, David; Egusquiza, Mònica; Valero, Carme; Egusquiza, Eduard

    2018-03-30

    Hydropower plants are of paramount importance for the integration of intermittent renewable energy sources in the power grid. In order to match the energy generated and consumed, Large hydraulic turbines have to work under off-design conditions, which may lead to dangerous unstable operating points involving the hydraulic, mechanical and electrical system. Under these conditions, the stability of the grid and the safety of the power plant itself can be compromised. For many Francis Turbines one of these critical points, that usually limits the maximum output power, is the full load instability. Therefore, these machines usually work far away from this unstable point, reducing the effective operating range of the unit. In order to extend the operating range of the machine, working closer to this point with a reasonable safety margin, it is of paramount importance to monitor and to control relevant parameters of the unit, which have to be obtained with an accurate sensor acquisition strategy. Within the framework of a large EU project, field tests in a large Francis Turbine located in Canada (rated power of 444 MW) have been performed. Many different sensors were used to monitor several working parameters of the unit for all its operating range. Particularly for these tests, more than 80 signals, including ten type of different sensors and several operating signals that define the operating point of the unit, were simultaneously acquired. The present study, focuses on the optimization of the acquisition strategy, which includes type, number, location, acquisition frequency of the sensors and corresponding signal analysis to detect the full load instability and to prevent the unit from reaching this point. A systematic approach to determine this strategy has been followed. It has been found that some indicators obtained with different types of sensors are linearly correlated with the oscillating power. The optimized strategy has been determined based on the

  11. Students' Scientific Epistemic Beliefs, Online Evaluative Standards, and Online Searching Strategies for Science Information: The Moderating Role of Cognitive Load Experience

    Science.gov (United States)

    Hsieh, Ya-Hui; Tsai, Chin-Chung

    2014-06-01

    The purpose of this study is to examine the moderating role of cognitive load experience between students' scientific epistemic beliefs and information commitments, which refer to online evaluative standards and online searching strategies. A total of 344 science-related major students participated in this study. Three questionnaires were used to ascertain the students' scientific epistemic beliefs, information commitments, and cognitive load experience. Structural equation modeling was then used to analyze the moderating effect of cognitive load, with the results revealing its significant moderating effect. The relationships between sophisticated scientific epistemic beliefs and the advanced evaluative standards used by the students were significantly stronger for low than for high cognitive load students. Moreover, considering the searching strategies that the students used, the relationships between sophisticated scientific epistemic beliefs and advanced searching strategies were also stronger for low than for high cognitive load students. However, for the high cognitive load students, only one of the sophisticated scientific epistemic belief dimensions was found to positively associate with advanced evaluative standard dimensions.

  12. A servo controlled gradient loading triaxial model test system for deep-buried cavern

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Xu-guang [College of Engineering, Ocean University of China, Qingdao 266100 (China); Shandong Provincial Key Laboratory of Ocean Engineering, Qingdao 266100 (China); Research Center of Geotechnical and Structural Engineering, Shandong University, Jinan 250061 (China); Zhang, Qiang-yong; Li, Shu-cai [Research Center of Geotechnical and Structural Engineering, Shandong University, Jinan 250061 (China)

    2015-10-15

    A servo controlled gradient loading model test system is developed to simulate the gradient geostress in deep-buried cavern. This system consists of the gradient loading apparatus, the digital servo control device, and the measurement system. Among them, the gradient loading apparatus is the main component which is used for exerting load onto the model. This loading apparatus is placed inside the counterforce wall/beam and is divided to several different loading zones, with each loading zone independently controlled. This design enables the gradient loading. Hence, the “real” geostress field surrounding the deep-buried cavern can be simulated. The loading or unloading process can be controlled by the human-computer interaction machines, i.e., the digital servo control system. It realizes the automation and visualization of model loading/unloading. In addition, this digital servo could control and regulate hydraulic loading instantaneously, which stabilizes the geostress onto the model over a long term. During the loading procedure, the collision between two adjacent loading platens is also eliminated by developing a guide frame. This collision phenomenon is induced by the volume shrinkage of the model when compressed in true 3D state. In addition, several accurate measurements, including the optical and grating-based method, are adopted to monitor the small deformation of the model. Hence, the distortion of the model could be accurately measured. In order to validate the performance of this innovative model test system, a 3D geomechanical test was conducted on a simulated deep-buried underground reservoir. The result shows that the radial convergence increases rapidly with the release of the stress in the reservoir. Moreover, the deformation increases with the increase of the gas production rate. This observation is consistence with field observation in petroleum engineering. The system is therefore capable of testing deep-buried engineering structures.

  13. A servo controlled gradient loading triaxial model test system for deep-buried cavern.

    Science.gov (United States)

    Chen, Xu-guang; Zhang, Qiang-yong; Li, Shu-cai

    2015-10-01

    A servo controlled gradient loading model test system is developed to simulate the gradient geostress in deep-buried cavern. This system consists of the gradient loading apparatus, the digital servo control device, and the measurement system. Among them, the gradient loading apparatus is the main component which is used for exerting load onto the model. This loading apparatus is placed inside the counterforce wall/beam and is divided to several different loading zones, with each loading zone independently controlled. This design enables the gradient loading. Hence, the "real" geostress field surrounding the deep-buried cavern can be simulated. The loading or unloading process can be controlled by the human-computer interaction machines, i.e., the digital servo control system. It realizes the automation and visualization of model loading/unloading. In addition, this digital servo could control and regulate hydraulic loading instantaneously, which stabilizes the geostress onto the model over a long term. During the loading procedure, the collision between two adjacent loading platens is also eliminated by developing a guide frame. This collision phenomenon is induced by the volume shrinkage of the model when compressed in true 3D state. In addition, several accurate measurements, including the optical and grating-based method, are adopted to monitor the small deformation of the model. Hence, the distortion of the model could be accurately measured. In order to validate the performance of this innovative model test system, a 3D geomechanical test was conducted on a simulated deep-buried underground reservoir. The result shows that the radial convergence increases rapidly with the release of the stress in the reservoir. Moreover, the deformation increases with the increase of the gas production rate. This observation is consistence with field observation in petroleum engineering. The system is therefore capable of testing deep-buried engineering structures.

  14. A servo controlled gradient loading triaxial model test system for deep-buried cavern

    International Nuclear Information System (INIS)

    Chen, Xu-guang; Zhang, Qiang-yong; Li, Shu-cai

    2015-01-01

    A servo controlled gradient loading model test system is developed to simulate the gradient geostress in deep-buried cavern. This system consists of the gradient loading apparatus, the digital servo control device, and the measurement system. Among them, the gradient loading apparatus is the main component which is used for exerting load onto the model. This loading apparatus is placed inside the counterforce wall/beam and is divided to several different loading zones, with each loading zone independently controlled. This design enables the gradient loading. Hence, the “real” geostress field surrounding the deep-buried cavern can be simulated. The loading or unloading process can be controlled by the human-computer interaction machines, i.e., the digital servo control system. It realizes the automation and visualization of model loading/unloading. In addition, this digital servo could control and regulate hydraulic loading instantaneously, which stabilizes the geostress onto the model over a long term. During the loading procedure, the collision between two adjacent loading platens is also eliminated by developing a guide frame. This collision phenomenon is induced by the volume shrinkage of the model when compressed in true 3D state. In addition, several accurate measurements, including the optical and grating-based method, are adopted to monitor the small deformation of the model. Hence, the distortion of the model could be accurately measured. In order to validate the performance of this innovative model test system, a 3D geomechanical test was conducted on a simulated deep-buried underground reservoir. The result shows that the radial convergence increases rapidly with the release of the stress in the reservoir. Moreover, the deformation increases with the increase of the gas production rate. This observation is consistence with field observation in petroleum engineering. The system is therefore capable of testing deep-buried engineering structures

  15. A free-piston Stirling engine/linear alternator controls and load interaction test facility

    Science.gov (United States)

    Rauch, Jeffrey S.; Kankam, M. David; Santiago, Walter; Madi, Frank J.

    1992-01-01

    A test facility at LeRC was assembled for evaluating free-piston Stirling engine/linear alternator control options, and interaction with various electrical loads. This facility is based on a 'SPIKE' engine/alternator. The engine/alternator, a multi-purpose load system, a digital computer based load and facility control, and a data acquisition system with both steady-periodic and transient capability are described. Preliminary steady-periodic results are included for several operating modes of a digital AC parasitic load control. Preliminary results on the transient response to switching a resistive AC user load are discussed.

  16. Development of novel control strategy for multiple circuit, roof top bus air conditioning system in hot humid countries

    Energy Technology Data Exchange (ETDEWEB)

    Khamis Mansour, M.; Musa, Md Nor; Wan Hassan, Mat Nawi; Saqr, Khalid M. [Thermo-Fluid Department, Faculty of Mechanical Engineering, Universiti Teknologi Malaysia, 81310 Johor Bahru (Malaysia)

    2008-06-15

    A novel control strategy to improve energy efficiency and to enhance passengers' thermal comfort of a new roof top bus multiple circuit air conditioning (AC) system operating on partial load conditions is presented. A novel strategy for automatic control of the AC system was developed based on numerous experimental test runs at various operating conditions, taking into account energy saving and thermal comfort without sacrificing the proper cycling rate of the system compressor. For this task, more than 50 test runs were conducted at different set point temperatures of 21, 22 and 23 C. Fanger's method was used to evaluate passenger thermal comfort, and the system energy consumption was also calculated. A performance comparison between that of the conventional AC system and that of the newly developed one has been conducted. The comparison revealed that the adopted control strategy introduces significant improvements in terms of thermal comfort and energy saving on various partial load conditions. Potential energy saving of up to 31.6% could be achieved. This results in a short payback period of 17 months. It was found from the economic analysis that the new system is able to save approximately 20.0% of the life cycle cost. (author)

  17. Development of novel control strategy for multiple circuit, roof top bus air conditioning system in hot humid countries

    International Nuclear Information System (INIS)

    Khamis Mansour, M.; Musa, Md Nor; Mat Nawi Wan Hassan; Saqr, Khalid M.

    2008-01-01

    A novel control strategy to improve energy efficiency and to enhance passengers' thermal comfort of a new roof top bus multiple circuit air conditioning (AC) system operating on partial load conditions is presented. A novel strategy for automatic control of the AC system was developed based on numerous experimental test runs at various operating conditions, taking into account energy saving and thermal comfort without sacrificing the proper cycling rate of the system compressor. For this task, more than 50 test runs were conducted at different set point temperatures of 21, 22 and 23 deg. C. Fanger's method was used to evaluate passenger thermal comfort, and the system energy consumption was also calculated. A performance comparison between that of the conventional AC system and that of the newly developed one has been conducted. The comparison revealed that the adopted control strategy introduces significant improvements in terms of thermal comfort and energy saving on various partial load conditions. Potential energy saving of up to 31.6% could be achieved. This results in a short payback period of 17 months. It was found from the economic analysis that the new system is able to save approximately 20.0% of the life cycle cost

  18. Integrated waste load allocation for river water pollution control under uncertainty: a case study of Tuojiang River, China.

    Science.gov (United States)

    Xu, Jiuping; Hou, Shuhua; Yao, Liming; Li, Chaozhi

    2017-07-01

    This paper presents a bi-level optimization waste load allocation programming model under a fuzzy random environment to assist integrated river pollution control. Taking account of the leader-follower decision-making in the water function zones framework, the proposed approach examines the decision making feedback relationships and conflict coordination between the river basin authority and the regional Environmental Protection Agency (EPA) based on the Stackelberg-Nash equilibrium strategy. In the pollution control system, the river basin authority, as the leader, allocates equitable emissions rights to different subareas, and the then subarea EPA, as the followers, reallocates the limited resources to various functional zones to minimize pollution costs. This research also considers the uncertainty in the water pollution management, and the uncertain input information is expressed as fuzzy random variables. The proposed methodological approach is then applied to Tuojiang River in China and the bi-level linear programming model solutions are achieved using the Karush-Kuhn-Tucker condition. Based on the waste load allocation scheme results and various scenario analyses and discussion, some operational policies are proposed to assist decision makers (DMs) cope with waste load allocation problem for integrated river pollution control for the overall benefits.

  19. Autonomous Control Strategy of DC Microgrid for Islanding Mode Using Power Line Communication

    Directory of Open Access Journals (Sweden)

    Dong-Keun Jeong

    2018-04-01

    Full Text Available This paper proposes a DC-bus signaling (DBS method for autonomous power management in a DC microgrid, used to improve its reliability. Centralized power management systems require communication between the power sources and loads. However, the DBS method operates based on the common DC-bus voltage and does not require communication. Based on the DC-bus voltage band, the DC-bus voltage can be used to inform the status of the DC-bus in various scenarios. The DC microgrid operates independently to maintain the system stably in the DC-bus voltage band. The DC microgrid can be divided into a grid-connected mode and an islanding mode. This paper proposes a control strategy based on power management of various independent components in islanding mode. In addition, the autonomous control method for switching the converter’s operation between grid-connected mode and islanding mode is proposed. A DC microgrid test bed consisting of a grid-connected AC/DC converter, a bidirectional DC/DC converter, a renewable energy simulator, DC home appliances and a DC-bus protector is used to test the proposed control strategy. The proposed autonomous control strategy is experimentally verified using the DC microgrid test bed.

  20. Preliminary Study on Structural Optimization with Control Variables Using Equivalent Static Loads for Spring-damper Control Systems

    International Nuclear Information System (INIS)

    Yoo, Nam-sun; Jung, Ui-Jin; Park, Gyung-Jin; Kim, Tai-Kyung

    2014-01-01

    An optimization method is proposed for the simultaneous design of structural and control systems using the equivalent static loads. In the past researches, the control parameters of such feedback gains are obtained to improve some performance in the steady-state. However, the actuators which have position and velocity feedback gains should be designed to exhibit a good performance in the time domain. In other words, the system analysis should be conducted for the transient-state in dynamic manner. In this research, a new equivalent static loads method is presented to treat the control variables as the design variables. The equivalent static loads (ESLs) set is defined as a static load set which generates the same displacement field as that from dynamic loads at a certain time. The calculated sets of ESLs are applied as multiple loading conditions in the optimization process. Several examples are solved to validate the proposed method

  1. Using System Dynamics to Define, Study, and Implement Smart Control Strategies on the Electric Power Grid

    Energy Technology Data Exchange (ETDEWEB)

    Lyle G. Roybal; Robert F Jeffers

    2013-07-01

    The United States electric power grid is the most complex and expansive control system in the world. Local generation control occurs at individual units based on response time and unit economics, larger regional control coordinates unit response to error conditions, and high level large-area regional control is ultimately administered by a network of humans guided by economic and resiliency related factors. Under normal operating conditions, the grid is a relatively slow moving entity that exhibits high inertia to outside stimuli, and behaves along repeatable diurnal and seasonal patterns. However, that paradigm is quickly changing because of the increasing implementation of renewable generation sources. Renewable generators by nature cannot be tightly controlled or scheduled. They appear like a negative load to the system with all of the variability associated with load on a larger scale. Also, grid-reactive loads (i.e. smart devices) can alter their consumption based on price or demand rules adding more variability to system behavior. This paper demonstrates how a systems dynamic modeling approach capable of operating over multiple time scales, can provide valuable insight into developing new “smart-grid” control strategies and devices needed to accommodate renewable generation and regulate the frequency of the grid.

  2. Optimal sizing and control strategy of isolated grid with wind power and energy storage system

    International Nuclear Information System (INIS)

    Luo, Yi; Shi, Lin; Tu, Guangyu

    2014-01-01

    Highlights: • An energy storage sizing scheme for wind powered isolated grid is developed. • A bi-level control strategy for wind-battery isolated grid is proposed. • The energy storage type selection method for Nan’ao island grid is presented. • The sizing method and the control strategy are verified based on the Nan’ao island. • The wind-battery demonstration system has great benefit for remote areas. - Abstract: Integrating renewable energy and energy storage system provides a prospective way for power supply of remote areas. Focused on the isolated grids comprising renewable energy generation and energy storage, an energy storage sizing method for taking account of the reliability requirement and a bi-level control strategy of the isolated grids are presented in this paper. Based on comparative analysis of current energy storage characteristics and practicability, Sodium–sulfur battery is recommended for power balance control in the isolated grids. The optimal size of the energy storage system is determined by genetic algorithm and sequential simulation. The annualized cost considering the compensation cost of curtailed wind power and load is minimized when the reliability requirement can be satisfied. The sizing method emphasizes the tradeoff between energy storage size and reliability of power supply. The bi-level control strategy is designed as upper level wide area power balance control in dispatch timescale and lower level battery energy storage system V/f control in real-time range for isolated operation. The mixed timescale simulation results of Nan’ao Island grid verify the effectiveness of the proposed sizing method and control strategy

  3. Left ventricular twist is load-dependent as shown in a large animal model with controlled cardiac load

    Directory of Open Access Journals (Sweden)

    A’roch Roman

    2012-06-01

    Full Text Available Abstract Background Left ventricular rotation and twist can be assessed noninvasively by speckle tracking echocardiography. We sought to characterize the effects of acute load change and change in inotropic state on rotation parameters as a measure of left ventricular (LV contractility. Methods Seven anesthetised juvenile pigs were studied, using direct measurement of left ventricular pressure and volume and simultaneous transthoracic echocardiography. Transient inflation of an inferior vena cava balloon (IVCB catheter produced controlled load reduction. First and last beats in the sequence of eight were analysed with speckle tracking (STE during the load alteration and analysed for change in rotation/twist during controlled load alteration at same contractile status. Two pharmacological inotropic interventions were also included to examine the same hypothesis in additionally conditions of increased and decreased myocardial contractility in each animal. Paired comparisons were made for different load states using the Wilcoxon’s Signed Rank test. Results The inferior vena cava balloon occlusion (IVCBO load change compared for first to last beat resulted in LV twist increase (11.67° ±2.65° vs. 16.17° ±3.56° respectively, p  Conclusions Peak systolic LV twist and peak early diastolic untwisting rate are load dependent. Differences in LV load should be included in the interpretation when serial measures of twist are compared.

  4. PENENTUAN RECEIVED DATE DENGAN LOAD-ORIENTED MANUFACRURING CONTROL

    Directory of Open Access Journals (Sweden)

    Sri Hartini

    2012-02-01

    Full Text Available Salah satu kunci kompetitif sebuah perusahaan make to order adalah ketepatan dalam pemenuhan waktu penerimaan pesanan pada konsumen yang telah dijanjikan perusahaan ( received date. Penentuan received date yang selama ini dilakukan oleh JI  kurang tepat karena hanya memperkirakan waktu sekitar 10 – 12 minggu tanpa mempertimbangkan faktor produksi. Penelitian ini merancang received date dengan model load-oriented manufacturing control dimana penentuan received date didasarkan pada perhitungan manufacturing lead time yang mempertimbangkan waktu pengiriman order ke konsumen, kapasitas yang tersedia pada tiap stasiun kerja, waktu proses pada stasiun kerja dan aliran produksi di lantai produksi. Hasil validasi perhitungan  penentuan received date order sesuai  dengan sistem produksi PT JI dan lebih valid dibanding sistem awal. Kata kunci : make to order, received date, manufacturing leadtime, load-oriented manufacturing control   One of the competitive key of a make to order company is the accuracy in fulfilling orders which has been promised by the company towards the consumers (received date. Determining received date which has been applied by JI recently is not sufficient because it only predicts 10-12 weeks of time without considering production factors. This research designs received date with load-oriented manufacturing control model where determining received date is based on calculating manufacturing lead time that considers the time needed to deliver orders to the consumer, capacity available for each work station, work station process time, and production flow within the production floor.  Validation results from the calculations for determining received date order is adjusted to PT JI  production system and is more valid than the first system. Keywords : make to order, received date, manufacturing leadtime, load-oriented manufacturing control

  5. BWR control blade replacement strategies

    Energy Technology Data Exchange (ETDEWEB)

    Kennard, M W [Stoller Nuclear Fuel, NAC International, Pleasantville, NY (United States); Harbottle, J E [Stoller Nuclear Fuel, NAC International, Thornbury, Bristol (United Kingdom)

    2000-02-01

    The reactivity control elements in a BWR, the control blades, perform three significant functions: provide shutdown margin during normal and accident operating conditions; provide overall core reactivity control; and provide axial power shaping control. As such, the blades are exposed to the core's neutron flux, resulting in irradiation of blade structural and absorber materials. Since the absorber depletes with time (if B{sub 4}C is used, it also swells) and the structural components undergo various degradation mechanisms (e.g., embrittlement, corrosion), the blades have limits on their operational lifetimes. Consequently, BWR utilities have implemented strategies that aim to maximize blade lifetimes while balancing operational costs, such as extending a refuelling outage to shuffle high exposure blades. This paper examines the blade replacement strategies used by BWR utilities operating in US, Europe and Asia by assembling information related to: the utility's specific blade replacement strategy; the impact the newer blade designs and changes in core operating mode were having on those strategies; the mechanical and nuclear limits that determined those strategies; the methods employed to ensure that lifetime limits were not exceeded during operation; and blade designs used (current and replacement blades). (author)

  6. BWR control blade replacement strategies

    International Nuclear Information System (INIS)

    Kennard, M.W.; Harbottle, J.E.

    2000-01-01

    The reactivity control elements in a BWR, the control blades, perform three significant functions: provide shutdown margin during normal and accident operating conditions; provide overall core reactivity control; and provide axial power shaping control. As such, the blades are exposed to the core's neutron flux, resulting in irradiation of blade structural and absorber materials. Since the absorber depletes with time (if B 4 C is used, it also swells) and the structural components undergo various degradation mechanisms (e.g., embrittlement, corrosion), the blades have limits on their operational lifetimes. Consequently, BWR utilities have implemented strategies that aim to maximize blade lifetimes while balancing operational costs, such as extending a refuelling outage to shuffle high exposure blades. This paper examines the blade replacement strategies used by BWR utilities operating in US, Europe and Asia by assembling information related to: the utility's specific blade replacement strategy; the impact the newer blade designs and changes in core operating mode were having on those strategies; the mechanical and nuclear limits that determined those strategies; the methods employed to ensure that lifetime limits were not exceeded during operation; and blade designs used (current and replacement blades). (author)

  7. Control Strategy of an Impulse Turbine for an Oscillating Water Column-Wave Energy Converter in Time-Domain Using Lyapunov Stability Method

    Directory of Open Access Journals (Sweden)

    Seung Kwan Song

    2016-10-01

    Full Text Available We present two control strategies for an oscillating water column-wave energy converter (OWC-WEC in the time domain. We consider a fixed OWC-WEC on the open sea with an impulse turbine module. This system mainly consists of a chamber, turbine and electric generator. For the time domain analysis, all of the conversion stages considering mutualities among them should be analyzed based on the Newtonian mechanics. According to the analysis of Newtonian mechanics, the hydrodynamics of wave energy absorption in the chamber and the turbine aerodynamic performance are directly coupled and share the internal air pressure term via the incompressible air assumption. The turbine aerodynamics and the dynamics of the electric generator are connected by torque load through the rotor shaft, which depends on an electric terminal load that acts as a control input. The proposed control strategies are an instant maximum turbine efficiency tracking control and a constant angular velocity of the turbine rotor control methods. Both are derived by Lyapunov stability analysis. Numerical simulations are carried out under irregular waves with various heights and periods in the time domain, and the results with the controllers are analyzed. We then compare these results with simulations carried out in the absence of the control strategy in order to prove the performance of the controllers.

  8. Coordination Control Strategy for AC/DC Hybrid Microgrids in Stand-Alone Mode

    Directory of Open Access Journals (Sweden)

    Dwi Riana Aryani

    2016-06-01

    Full Text Available Interest in DC microgrids is rapidly increasing along with the improvement of DC power technology because of its advantages. To support the integration process of DC microgrids with the existing AC utility grids, the form of hybrid AC/DC microgrids is considered for higher power conversion efficiency, lower component cost and better power quality. In the system, AC and DC portions are connected through interlink bidirectional AC/DC converters (IC with a proper control system and power management. In the stand-alone operation mode of AC/DC hybrid microgrids, the control of power injection through the IC is crucial in order to maintain the system security. This paper mainly deals with a coordination control strategy of IC and a battery energy storage system (BESS converter under stand-alone operation. A coordinated control strategy for the IC, which considers the state of charge (SOC level of BESS and the load shedding scheme as the last resort, is proposed to obtain better power sharing between AC and DC subgrids. The scheme will be tested with a hybrid AC/DC microgrid, using the tool of the PSCAD/EMTDC software.

  9. Load frequency control of three area interconnected hydro-thermal ...

    African Journals Online (AJOL)

    This paper present analysis on dynamic performance of Load Frequency Control (LFC) of three area interconnected hydrothermal reheat power system by the use of Artificial Intelligent and PI Controller. In the proposed scheme, control methodology developed using conventional PI controller, Artificial Neural Network ...

  10. Improving electrical power systems reliability through locally controlled distributed curtailable load

    Science.gov (United States)

    Dehbozorgi, Mohammad Reza

    2000-10-01

    Improvements in power system reliability have always been of interest to both power companies and customers. Since there are no sizable electrical energy storage elements in electrical power systems, the generated power should match the load demand at any given time. Failure to meet this balance may cause severe system problems, including loss of generation and system blackouts. This thesis proposes a methodology which can respond to either loss of generation or loss of load. It is based on switching of electric water heaters using power system frequency as the controlling signal. The proposed methodology encounters, and the thesis has addressed, the following associated problems. The controller must be interfaced with the existing thermostat control. When necessary to switch on loads, the water in the tank should not be overheated. Rapid switching of blocks of load, or chattering, has been considered. The contributions of the thesis are: (A) A system has been proposed which makes a significant portion of the distributed loads connected to a power system to behave in a predetermined manner to improve the power system response during disturbances. (B) The action of the proposed system is transparent to the customers. (C) The thesis proposes a simple analysis for determining the amount of such loads which might be switched and relates this amount to the size of the disturbances which can occur in the utility. (D) The proposed system acts without any formal communication links, solely using the embedded information present system-wide. (E) The methodology of the thesis proposes switching of water heater loads based on a simple, localized frequency set-point controller. The thesis has identified the consequent problem of rapid switching of distributed loads, which is referred to as chattering. (F) Two approaches have been proposed to reduce chattering to tolerable levels. (G) A frequency controller has been designed and built according to the specifications required to

  11. Control strategy of wind turbine based on permanent magnet synchronous generator and energy storage for stand-alone systems

    DEFF Research Database (Denmark)

    Deng, Fujin; Liu, Dong; Chen, Zhe

    2017-01-01

    This paper investigates a variable speed wind turbine based on permanent magnet synchronous generator and a full-scale power converter in a stand-alone system. An energy storage system(ESS) including battery and fuel cell-electrolyzer combination is connected to the DC link of the full-scale power...... converter through the power electronics interface. Wind is the primary power source of the system, the battery and FC-electrolyzer combination is used as a backup and a long-term storage system to provide or absorb power in the stand-alone system, respectively. In this paper, a control strategy is proposed...... for the operation of this variable speed wind turbine in a stand-alone system, where the generator-side converter and the ESS operate together to meet the demand of the loads. This control strategy is competent for supporting the variation of the loads or wind speed and limiting the DC-link voltage of the full...

  12. Fuzzy controller for a system with uncertain load

    DEFF Research Database (Denmark)

    Kulczycki, P.; Wisniewski, Rafal

    2002-01-01

    In many applications of motion control, problems associated with imprecisely measured or changing load (a mass or a moment of inertia) can be a serious obstacle in the formation of satisfactory controlling systems. This barrier compels the designer to include various kinds of uncertainties...

  13. A Wind Farm Controller for Load and Power Optimization in a Farm

    DEFF Research Database (Denmark)

    Soleimanzadeh, Maryam; Brand, Arno; Wisniewski, Rafal

    2011-01-01

    This paper describes the design procedure of an optimal wind farm controller. The controller optimizes the structural load and power production simultaneously, on the basis of an analytical wind farm model. The farm model delivers maps of wind, loads and energy in the wind farm. Moreover, the model...... computes the wind speed at the turbines, turbine bending moments and aerodynamic power and torque. The optimal control problem is formulated based on the model for two different wind directions. The controller determines the reference signals for each individual wind turbine controller in two scenarios...... based on low and high wind speed. In low wind speed, the reference signals for rotor speed are adjusted, taking the trade-off between power maximization and load minimization into account. In high wind speed, the power and pitch angle reference signals are determined while structural loads are minimized....

  14. Development of a web-based remote load supervision and control system

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Wei-Fu; Wu, Yu-Chi; Chiu, Chui-Wen [National United University, Miao-Li (Taiwan). Department of Electrical Engineering

    2006-07-15

    The ability to remotely acquire information and even to control appliances/devices at fingertips over the Internet is becoming desirable to the general public as well as professionals. In this paper, a web-based remote electric load supervision and control (WBRELSAC) system with automatic meter reading and demand control via programmable logic controllers (PLCs) is presented. For both utilities and industrial/commercial customers, the electric load supervision and control (ELSAC) system is a critical function to their load management. However, most high voltage customers do not have enough capital to build a regular-scale supervisory control and data acquisition system as the one for utilities. Therefore, we adopt the industrial-widely-used PLCs in WBRELSAC. In order to make a non-web-based PLC become web-controllable, we develop a graphical-control interface and utilize Internet techniques to implement our system. Based on the performance test conducted under the Laboratory environment, the proposed WBRELSAC architecture is cost-effective and suitable for industrial applications. (author)

  15. Frequency domain design of gain scheduling control for large wind systems in full-load region

    International Nuclear Information System (INIS)

    Burlibaşa, A.; Ceangă, E.

    2014-01-01

    Highlights: • A large wind energy system, operating under full-load regime, is considered. • According to its particularities in frequency domain, control law design is provided. • These particularities are influenced by the interactions of wind–tower–blade ensemble. • Control low, within gain scheduling strategy, is achieved imposing stability reserve. • Supplementary a criterion, aimed at reducing mechanical loads, is imposed. - Abstract: The paper presents the issue of power control law synthesis, in the case of a large wind system that operates under full-load regime, based on dynamic properties details in frequency domain. Solving this problem involves two phases: the establishment of a linearized model as faithfully as possible in various operating points of the full-load region, and synthesis of the power controller, considered with classic structure, taking into account frequency particularities of the obtained linearized model. Obtained linear model of the controlled process is of order 16 and encloses subsystems for tower fore-aft oscillations damping, and for drive-train torsion oscillations damping. The designed controller contains a PI component and a lag compensator for dynamic correction at high frequencies. It is known that the main features of wind system dynamics generated by the interaction of wind–tower–blade ensemble cause a gap in the gain characteristic of the model and complex conjugate zeros, which can move between right and left half-planes, depending on the average wind speed value. Consequently, for control law synthesis an interactive frequency solution is adopted. This is “transparent” in relation to particularities induced by wind–tower–blade interaction. This solution allows evaluation of the extent to which control law is affected by the subsystem for tower oscillations damping. Given the strong dependence between the model and the mean wind speed value, a gain scheduling control law is designed. At

  16. Central FPGA-based destination and load control in the LHCb MHz event readout

    International Nuclear Information System (INIS)

    Jacobsson, R.

    2012-01-01

    The readout strategy of the LHCb experiment is based on complete event readout at 1 MHz. A set of 320 sub-detector readout boards transmit event fragments at total rate of 24.6 MHz at a bandwidth usage of up to 70 GB/s over a commercial switching network based on Gigabit Ethernet to a distributed event building and high-level trigger processing farm with 1470 individual multi-core computer nodes. In the original specifications, the readout was based on a pure push protocol. This paper describes the proposal, implementation, and experience of a non-conventional mixture of a push and a pull protocol, akin to credit-based flow control. An FPGA-based central master module, partly operating at the LHC bunch clock frequency of 40.08 MHz and partly at a double clock speed, is in charge of the entire trigger and readout control from the front-end electronics up to the high-level trigger farm. One FPGA is dedicated to controlling the event fragment packing in the readout boards, the assignment of the farm node destination for each event, and controls the farm load based on an asynchronous pull mechanism from each farm node. This dynamic readout scheme relies on generic event requests and the concept of node credit allowing load control and trigger rate regulation as a function of the global farm load. It also allows the vital task of fast central monitoring and automatic recovery in-flight of failing nodes while maintaining dead-time and event loss at a minimum. This paper demonstrates the strength and suitability of implementing this real-time task for a very large distributed system in an FPGA where no random delays are introduced, and where extreme reliability and accurate event accounting are fundamental requirements. It was in use during the entire commissioning phase of LHCb and has been in faultless operation during the first two years of physics luminosity data taking.

  17. Central FPGA-based destination and load control in the LHCb MHz event readout

    Science.gov (United States)

    Jacobsson, R.

    2012-10-01

    The readout strategy of the LHCb experiment is based on complete event readout at 1 MHz. A set of 320 sub-detector readout boards transmit event fragments at total rate of 24.6 MHz at a bandwidth usage of up to 70 GB/s over a commercial switching network based on Gigabit Ethernet to a distributed event building and high-level trigger processing farm with 1470 individual multi-core computer nodes. In the original specifications, the readout was based on a pure push protocol. This paper describes the proposal, implementation, and experience of a non-conventional mixture of a push and a pull protocol, akin to credit-based flow control. An FPGA-based central master module, partly operating at the LHC bunch clock frequency of 40.08 MHz and partly at a double clock speed, is in charge of the entire trigger and readout control from the front-end electronics up to the high-level trigger farm. One FPGA is dedicated to controlling the event fragment packing in the readout boards, the assignment of the farm node destination for each event, and controls the farm load based on an asynchronous pull mechanism from each farm node. This dynamic readout scheme relies on generic event requests and the concept of node credit allowing load control and trigger rate regulation as a function of the global farm load. It also allows the vital task of fast central monitoring and automatic recovery in-flight of failing nodes while maintaining dead-time and event loss at a minimum. This paper demonstrates the strength and suitability of implementing this real-time task for a very large distributed system in an FPGA where no random delays are introduced, and where extreme reliability and accurate event accounting are fundamental requirements. It was in use during the entire commissioning phase of LHCb and has been in faultless operation during the first two years of physics luminosity data taking.

  18. Low Load Limit Extension for Gasoline Compression Ignition Using Negative Valve Overlap Strategy

    KAUST Repository

    Vallinayagam, R.

    2018-04-03

    Gasoline compression ignition (GCI) is widely studied for the benefits of simultaneous reduction in nitrogen oxide (NO) and soot emissions without compromising the engine efficiency. Despite this advantage, the operational range for GCI is not widely expanded, as the auto-ignition of fuel at low load condition is difficult. The present study aims to extend the low load operational limit for GCI using negative valve overlap (NVO) strategy. The engine used for the current experimentation is a single cylinder diesel engine that runs at an idle speed of 800 rpm with a compression ratio of 17.3. The engine is operated at homogeneous charge compression ignition (HCCI) and partially premixed combustion (PPC) combustion modes with the corresponding start of injection (SOI) at 180 CAD (aTDC) and 30 CAD (aTDC), respectively. In the presented work, intake air temperature is used as control parameter to maintain combustion stability at idle and low load condition, while the intake air pressure is maintained at 1 bar (ambient). The engine is equipped with variable valve cam phasers that can phase both inlet and exhaust valves from the original timing. For the maximum cam phasing range (56 CAD) at a valve lift of 0.3 mm, the maximum allowable positive valve overlap was 20 CAD. In the present study, the exhaust cam is phased to 26 CAD and 6 CAD and the corresponding NVO is noted to be 10 CAD and 30 CAD, respectively. With exhaust cam phasing adjustment, the exhaust valve is closed early to retain hot residual gases inside the cylinder. As such, the in-cylinder temperature is increased and a reduction in the required intake air temperature to control combustion phasing is possible. For a constant combustion phasing of 3 CAD (aTDC), a minimum load of indicated mean effective pressure (IMEP) = 1 bar is attained for gasoline (RON = 91) at HCCI and PPC modes. The coefficient of variance was observed to below 5% at these idle and low load conditions. At the minimum load point, the

  19. Data-Driven Predictive Direct Load Control of Refrigeration Systems

    DEFF Research Database (Denmark)

    Shafiei, Seyed Ehsan; Knudsen, Torben; Wisniewski, Rafal

    2015-01-01

    A predictive control using subspace identification is applied for the smart grid integration of refrigeration systems under a direct load control scheme. A realistic demand response scenario based on regulation of the electrical power consumption is considered. A receding horizon optimal control...... is proposed to fulfil two important objectives: to secure high coefficient of performance and to participate in power consumption management. Moreover, a new method for design of input signals for system identification is put forward. The control method is fully data driven without an explicit use of model...... against real data. The performance improvement results in a 22% reduction in the energy consumption. A comparative simulation is accomplished showing the superiority of the method over the existing approaches in terms of the load following performance....

  20. The method of measurement and synchronization control for large-scale complex loading system

    International Nuclear Information System (INIS)

    Liao Min; Li Pengyuan; Hou Binglin; Chi Chengfang; Zhang Bo

    2012-01-01

    With the development of modern industrial technology, measurement and control system was widely used in high precision, complex industrial control equipment and large-tonnage loading device. The measurement and control system is often used to analyze the distribution of stress and displacement in the complex bearing load or the complex nature of the mechanical structure itself. In ITER GS mock-up with 5 flexible plates, for each load combination, detect and measure potential slippage between the central flexible plate and the neighboring spacers is necessary as well as the potential slippage between each pre-stressing bar and its neighboring plate. The measurement and control system consists of seven sets of EDC controller and board, computer system, 16-channel quasi-dynamic strain gauge, 25 sets of displacement sensors, 7 sets of load and displacement sensors in the cylinders. This paper demonstrates the principles and methods of EDC220 digital controller to achieve synchronization control, and R and D process of multi-channel loading control software and measurement software. (authors)

  1. Impact of load management on the energy management strategy of a wind-short hydro hybrid system in frequency based pricing

    International Nuclear Information System (INIS)

    Malakar, T.; Goswami, S.K.; Sinha, A.K.

    2014-01-01

    Highlights: • This paper presents a new profit centric operating strategy of a hybrid power system under market environment. • The profit is ensured by optimal coordination of RES and load management approach. • The problem is formulated as dynamic optimization problem and solved using ABC algorithm. • Comparison shows that the proposed approach results more profit for the hybrid system. - Abstract: In the post restructuring era of electrical power system, each of the generating farm or utility has its own business strategy in terms of generation planning, load management and for other decisions. The basic objective of the utility is to maximize the operational profit for a given period of time. Generation scheduling for a utility with wind farm largely depends on the accuracy of wind power prediction. Therefore, it is important to explore the suitability of load management approach in coordination with the use of energy storage facility to compensate the uncertainty in wind power generation. This paper focuses mainly the operating strategy of a grid connected small hybrid power system to maximize its profit by adopting coordination between load management technique and utilization of storage plant under frequency based pricing. The optimum load scheduling has been implemented to utilities own local load. An hourly-discretized optimization algorithm is proposed and solved using artificial bee colony algorithm. To verify the effectiveness of the proposed method, the optimization problem is solved for varied wind power scenarios with different demand expectations cases in a day ahead Indian electricity market. It is noted that the proposed load management approach results more profit for the hybrid system because of better power management compared to the case when load scheduling has not been incorporated. The solution of the proposed optimization algorithm gives the strategies to be followed by the hybrid system how to operate its pump storage unit and to

  2. National Drug Control Strategy, 2011

    Science.gov (United States)

    Office of National Drug Control Policy, 2011

    2011-01-01

    In May of 2010, President Obama released the Administration's inaugural "National Drug Control Strategy". Based on the premise that drug use and its consequences pose a threat not just to public safety, but also to public health, the 2010 "Strategy" represented the first comprehensive rebalancing of Federal drug control policy in the nearly 40…

  3. HTGR-GT and electrical load integrated control

    International Nuclear Information System (INIS)

    Chan, T.; Openshaw, F.; Pfremmer, D.

    1980-05-01

    A discussion of the control and operation of the HTGR-GT power plant is presented in terms of its closely coupled electrical load and core cooling functions. The system and its controls are briefly described and comparisons are made with more conventional plants. The results of analyses of selected transients are presented to illustrate the operation and control of the HTGR-GT. The events presented were specifically chosen to show the controllability of the plant and to highlight some of the unique characteristics inherent in this multiloop closed-cycle plant

  4. Economic Benefits of Advanced Control Strategies in Biological Nutrient Removal Systems

    DEFF Research Database (Denmark)

    Carstensen, J.; Nielsen, M.K.; Harremoës, Poul

    1994-01-01

    little regards to the variations in load and biomass activity. However, these dynamics can be evaluated on-line using grey box models to describe the most important features of the hydraulic and biological processes. Simulation studies of plants with an alternating process have shown that control...... strategies incorporating information from the grey box models are capable of reducing the total nitrogen discharge as well as energy costs. These results have a major impact on both existing and future plants. In fact, it is expected that future plants can be reduced with 10-20 per cent in size...

  5. Design of a fractional order PID controller using GBMO algorithm for load-frequency control with governor saturation consideration.

    Science.gov (United States)

    Zamani, Abbasali; Barakati, S Masoud; Yousofi-Darmian, Saeed

    2016-09-01

    Load-frequency control is one of the most important issues in power system operation. In this paper, a Fractional Order PID (FOPID) controller based on Gases Brownian Motion Optimization (GBMO) is used in order to mitigate frequency and exchanged power deviation in two-area power system with considering governor saturation limit. In a FOPID controller derivative and integrator parts have non-integer orders which should be determined by designer. FOPID controller has more flexibility than PID controller. The GBMO algorithm is a recently introduced search method that has suitable accuracy and convergence rate. Thus, this paper uses the advantages of FOPID controller as well as GBMO algorithm to solve load-frequency control. However, computational load will higher than conventional controllers due to more complexity of design procedure. Also, a GBMO based fuzzy controller is designed and analyzed in detail. The performance of the proposed controller in time domain and its robustness are verified according to comparison with other controllers like GBMO based fuzzy controller and PI controller that used for load-frequency control system in confronting with model parameters variations. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.

  6. 40 CFR 123.46 - Individual control strategies.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 21 2010-07-01 2010-07-01 false Individual control strategies. 123.46... PROGRAM REQUIREMENTS Transfer of Information and Permit Review § 123.46 Individual control strategies. (a..., approval, and implementation an individual control strategy for each point source identified by the State...

  7. Economic Analysis of Immunization Strategies for PRRS Control [corrected].

    Directory of Open Access Journals (Sweden)

    Daniel C L Linhares

    Full Text Available Porcine reproductive and respiratory syndrome virus (PRRSv is a swine-specific pathogen that causes significant increases in production costs. When a breeding herd becomes infected, in an attempt to hasten control and elimination of PRRSv, some veterinarians have adopted a strategy called load-close-expose which consists of interrupting replacement pig introductions into the herd for several weeks (herd closure and exposing the whole herd to a replicating PRRSv to boost herd immunity. Either modified-live virus (MLV vaccine or live field-virus inoculation (FVI is used. This study consisted of partial budget analyses to compare MLV to FVI as the exposure method of load-close-expose program to control and eliminate PRRSv from infected breeding herds, and secondly to estimate benefit / cost of vaccinating sow herds preventatively. Under the assumptions used in this study, MLV held economic advantage over FVI. However, sensitivity analysis revealed that decreasing margin over variable costs below $ 47.32, or increasing PRRSv-attributed cost above $18.89 or achieving time-to-stability before 25 weeks resulted in advantage of FVI over MLV. Preventive vaccination of sow herds was beneficial when the frequency of PRRSv infection was at least every 1 year and 9 months [corrected]. The economics of preventative vaccination was minimally affected by cost attributed to field-type PRRSv infection on growing pigs or by the breeding herd productivity level. The models developed and described in this paper provide valuable tools to assist veterinarians in their efforts to control PRRSv.

  8. pH-controlled drug loading and release from biodegradable microcapsules.

    Science.gov (United States)

    Zhao, Qinghe; Li, Bingyun

    2008-12-01

    Microcapsules made of biopolymers are of both scientific and technological interest and have many potential applications in medicine, including their use as controlled drug delivery devices. The present study makes use of the electrostatic interaction between polycations and polyanions to form a multilayered microcapsule shell and also to control the loading and release of charged drug molecules inside the microcapsule. Micron-sized calcium carbonate (CaCO3) particles were synthesized and integrated with chondroitin sulfate (CS) through a reaction between sodium carbonate and calcium nitrate tetrahydrate solutions suspended with CS macromolecules. Oppositely charged biopolymers were alternately deposited onto the synthesized particles using electrostatic layer-by-layer self-assembly, and glutaraldehyde was introduced to cross-link the multilayered shell structure. Microcapsules integrated with CS inside the multilayered shells were obtained after decomposition of the CaCO3 templates. The integration of a matrix (i.e., CS) permitted the subsequent selective control of drug loading and release. The CS-integrated microcapsules were loaded with a model drug, bovine serum albumin labeled with fluorescein isothiocyanate (FITC-BSA), and it was shown that pH was an effective means of controlling the loading and release of FITC-BSA. Such CS-integrated microcapsules may be used for controlled localized drug delivery as biodegradable devices, which have advantages in reducing systemic side effects and increasing drug efficacy.

  9. Proportional resonant individual pitch control for mitigation of wind turbines loads

    DEFF Research Database (Denmark)

    Zhang, Yunqian; Chen, Zhe; Cheng, Ming

    2013-01-01

    attenuation. The individual pitch control (IPC) is a promising way to reduce the wind turbine loads. This study presents a proportional resonant (PR) IPC, which does not need the measurement of blade azimuth angle and multiple complex Coleman transformations between rotational coordinate frame and stationary...... coordinate frame. The new strategy can attenuate the 1p and higher harmonics on the wind turbine blades as well as 3p on the hub without any filters. The wind turbine code fatigue, aerodynamics, structures and turbulence is applied to a doubly fed induction generator-based wind power generation system....... The simulations are performed on the National Renewable Energy Laboratory 1.5 MW upwind reference wind turbine model. The simulation results are presented and discussed to demonstrate the capability and effectiveness of the proposed PR IPC method....

  10. Wind Turbine Load Mitigation based on Multivariable Robust Control and Blade Root Sensors

    Science.gov (United States)

    Díaz de Corcuera, A.; Pujana-Arrese, A.; Ezquerra, J. M.; Segurola, E.; Landaluze, J.

    2014-12-01

    This paper presents two H∞ multivariable robust controllers based on blade root sensors' information for individual pitch angle control. The wind turbine of 5 MW defined in the Upwind European project is the reference non-linear model used in this research work, which has been modelled in the GH Bladed 4.0 software package. The main objective of these controllers is load mitigation in different components of wind turbines during power production in the above rated control zone. The first proposed multi-input multi-output (MIMO) individual pitch H" controller mitigates the wind effect on the tower side-to-side acceleration and reduces the asymmetrical loads which appear in the rotor due to its misalignment. The second individual pitch H" multivariable controller mitigates the loads on the three blades reducing the wind effect on the bending flapwise and edgewise momentums in the blades. The designed H" controllers have been validated in GH Bladed and an exhaustive analysis has been carried out to calculate fatigue load reduction on wind turbine components, as well as to analyze load mitigation in some extreme cases.

  11. Towards development of novel immunization strategies against leishmaniasis using PLGA nanoparticles loaded with kinetoplastid membrane protein-11

    Directory of Open Access Journals (Sweden)

    Santos DM

    2012-04-01

    Full Text Available Diego M Santos1, Marcia W Carneiro1, Tatiana R de Moura1, Kiyoshi Fukutani1, Jorge Clarencio1, Manuel Soto2, Socorro Espuelas3,4, Claudia Brodskyn1,5, Aldina Barral1,5, Manoel Barral-Netto1,5, Camila I de Oliveira1,51Centro de Pesquisas Gonçalo Moniz, FIOCRUZ, Salvador, BA, Brazil; 2Centro de Biología Molecular Severo Ochoa, Consejo Superior de Investigaciones Cientificas, Departamento de Biologia Molecular, Universidad Autonoma de Madrid, Madrid; 3Departamento de Farmacia y Tecnología Farmacéutica, 4Instituto de Salud Tropical, Facultad de Farmacia, Universidad de Navarra, Pamplona, Spain; 5Instituto de Investigação em Imunologia, Salvador, BA, BrazilBackground: Vaccine development has been a priority in the fight against leishmaniases, which are vector-borne diseases caused by Leishmania protozoa. Among the different immunization strategies employed to date is inoculation of plasmid DNA coding for parasite antigens, which has a demonstrated ability to induce humoral and cellular immune responses. In this sense, inoculation of plasmid DNA encoding Leishmania kinetoplasmid membrane protein-11 (KMP-11 was able to confer protection against visceral leishmaniasis. However, recently the use of antigen delivery systems such as poly(lactic-co-glycolic acid (PLGA nanoparticles has also proven effective for eliciting protective immune responses.Methods: In the present work, we tested two immunization strategies with the goal of obtaining protection, in terms of lesion development and parasite load, against cutaneous leishmaniasis caused by L. braziliensis. One strategy involved immunization with plasmid DNA encoding L. infantum chagasi KMP-11. Alternatively, mice were primed with PLGA nanoparticles loaded with the recombinant plasmid DNA and boosted using PLGA nanoparticles loaded with recombinant KMP-11.Results: Both immunization strategies elicited detectable cellular immune responses with the presence of both proinflammatory and anti

  12. Frequency Transient Suppression in Hybrid Electric Ship Power Systems: A Model Predictive Control Strategy for Converter Control with Energy Storage

    Directory of Open Access Journals (Sweden)

    Viknash Shagar

    2018-03-01

    Full Text Available This paper aims to understand how the common phenomenon of fluctuations in propulsion and service load demand contribute to frequency transients in hybrid electric ship power systems. These fluctuations arise mainly due to changes in sea conditions resulting in significant variations in the propulsion load demand of ships. This leads to poor power quality for the power system that can potentially cause hazardous conditions such as blackout on board the ship. Effects of these fluctuations are analysed using a hybrid electric ship power system model and a proposed Model Predictive Control (MPC strategy to prevent propagation of transients from the propellers into the shipboard power system. A battery energy storage system, which is directly connected to the DC-link of the frequency converter, is used as the smoothing element. Case studies that involve propulsion and service load changes have been carried out to investigate the efficacy of the proposed solution. Simulation results show that the proposed solution with energy storage and MPC is able to contain frequency transients in the shipboard power system within the permissible levels stipulated by the relevant power quality standards. These findings will help ship builders and operators to consider using battery energy storage systems controlled by advanced control techniques such as MPC to improve the power quality on board ships.

  13. Deterministic methods for multi-control fuel loading optimization

    Science.gov (United States)

    Rahman, Fariz B. Abdul

    We have developed a multi-control fuel loading optimization code for pressurized water reactors based on deterministic methods. The objective is to flatten the fuel burnup profile, which maximizes overall energy production. The optimal control problem is formulated using the method of Lagrange multipliers and the direct adjoining approach for treatment of the inequality power peaking constraint. The optimality conditions are derived for a multi-dimensional multi-group optimal control problem via calculus of variations. Due to the Hamiltonian having a linear control, our optimal control problem is solved using the gradient method to minimize the Hamiltonian and a Newton step formulation to obtain the optimal control. We are able to satisfy the power peaking constraint during depletion with the control at beginning of cycle (BOC) by building the proper burnup path forward in time and utilizing the adjoint burnup to propagate the information back to the BOC. Our test results show that we are able to achieve our objective and satisfy the power peaking constraint during depletion using either the fissile enrichment or burnable poison as the control. Our fuel loading designs show an increase of 7.8 equivalent full power days (EFPDs) in cycle length compared with 517.4 EFPDs for the AP600 first cycle.

  14. Control of power distribution and the safety of a WWER-1000 reactor during operation in a load-following regime

    International Nuclear Information System (INIS)

    Filipchuk, E.V.; Dunaev, V.G.; Luk'yanets, I.A.; Potapenko, P.T.; Timokhin, E.S.; Voznesenskij, V.A.; Mitin, V.I.

    1984-01-01

    An important task in ensuring the operational safety of a nuclear power plant with a vessel-type water-cooled, water-moderated reactor is the development of algorithms for controlling power distribution in base-load and load-following regimes. The control strategy must ensure that the form of power distribution is maintained within the permissible limits in the case of situations presenting a nuclear hazard and of xenon fluctuations when there are variations in power output. The task of controlling power distribution can be broken down into an axial problem and a radial-azimuthal problem. For maintenance of the form of axial power distribution an algorithm of optimum fast-action control is proposed; for maintenance of the radial-azimuthal form, an algorithm of optimum (i.e. best) approximation to the given distribution of control. The two control problems are solved by using a single computerized procedure based on mathematical programming. The algorithms are designed for use in computerized control. The paper presents the results of algorithm simulation. The authors propose that in the first stage, activation of the control systems should involve the operator, who can view the sequence of actions on a display screen. (author)

  15. New control strategy of stand-alone brushless doubly-fed induction generator for supplying unbalanced loads in ship shaft power generation system

    DEFF Research Database (Denmark)

    Liu, Yi; Xu, Wei; Xiong, Fei

    2017-01-01

    The ship shaft power generation system based on a stand-alone brushless doubly-fed induction generator (BDFIG) have demonstrated excellent saving-energy performance. This paper presents a new control scheme of the stand-alone BDFIG for supplying unbalanced loads in the ship shaft power generation...

  16. Changes in resonance frequency analysis assessed by Osstell mentor during osseointegration: comparison between immediately loaded implants and control implants without load

    Directory of Open Access Journals (Sweden)

    M. González-Jaranay

    2014-10-01

    Full Text Available Aim: The aim of this prospective clinical study was to evaluate the changes in resonance frequency analysis (RFA, assessed by Osstell Mentor, obtaining information on the implant stability quotient (ISQ during implants tissue integration for immediately loaded and non-loaded control implants. Materials and methods: A total of 40 implants, 20 implants with no immediate loading (control and 20 immediately loaded implants (test, were placed in 15 patients. ISQ implants was evaluated at baseline and at 6 and 8 weeks. Provisional crowns were removed at 8 weeks, when the definitive restoration was placed. Data of control and test implants and maxillary and mandibular areas were statistically compared. Results: At 8 weeks, all implants were integrated and there were no major postoperative complications. A statistically significant difference was found only at baseline between test and control maxillary implants (p=0.009 but not at 6 or 8 weeks (p>0.05. Conclusion: Immediate loading procedures may be applied with primary stability ISQ values >60 and inserted with a force of ≥30 N. The Osstell Mentor RFA may offer an objective method to determine when implant stability is adequate for immediate loading.

  17. Effects of Cognitive Load on Driving Performance: The Cognitive Control Hypothesis.

    Science.gov (United States)

    Engström, Johan; Markkula, Gustav; Victor, Trent; Merat, Natasha

    2017-08-01

    The objective of this paper was to outline an explanatory framework for understanding effects of cognitive load on driving performance and to review the existing experimental literature in the light of this framework. Although there is general consensus that taking the eyes off the forward roadway significantly impairs most aspects of driving, the effects of primarily cognitively loading tasks on driving performance are not well understood. Based on existing models of driver attention, an explanatory framework was outlined. This framework can be summarized in terms of the cognitive control hypothesis: Cognitive load selectively impairs driving subtasks that rely on cognitive control but leaves automatic performance unaffected. An extensive literature review was conducted wherein existing results were reinterpreted based on the proposed framework. It was demonstrated that the general pattern of experimental results reported in the literature aligns well with the cognitive control hypothesis and that several apparent discrepancies between studies can be reconciled based on the proposed framework. More specifically, performance on nonpracticed or inherently variable tasks, relying on cognitive control, is consistently impaired by cognitive load, whereas the performance on automatized (well-practiced and consistently mapped) tasks is unaffected and sometimes even improved. Effects of cognitive load on driving are strongly selective and task dependent. The present results have important implications for the generalization of results obtained from experimental studies to real-world driving. The proposed framework can also serve to guide future research on the potential causal role of cognitive load in real-world crashes.

  18. Modeling and Control of a teletruck using electronic load sensing

    DEFF Research Database (Denmark)

    Hansen, Rico Hjerm; Iversen, Asger Malte; Jensen, Mads Schmidt

    2010-01-01

    system is most commonly controlled using a hydro-mechanical control scheme called Hydraulic Load Sensing (HLS). However, with the demands for increased efficiency and controllability the HLS solutions are reaching their limits. Motivated by availability of electronic controllable fluid power...... components and the potential of increased dynamic performance and efficiency, this paper investigates how HLS can be replaced with electronic control, i.e. Electronic Load Sensing (ELS). The investigation is performed by taking a specific application, a teletruck, and replace the HLS control with ELS. To aid...... the controller design for the ELS system, a complete model of the teletruck’s articulated arm and fluid power system is developed. To show the feasibility, a preliminary control structure for the ELS system is developed. The controller is tested on the machine, validating that features such as pump pressure...

  19. Linear active disturbance rejection-based load frequency control concerning high penetration of wind energy

    International Nuclear Information System (INIS)

    Tang, Yanmei; Bai, Yan; Huang, Congzhi; Du, Bin

    2015-01-01

    Highlights: • A disturbance rejection solution to the load frequency control issue is proposed. • Several power systems with wind energy conversation system have been tested. • A tuning algorithm of the controller parameters was proposed. • The performance of the proposed approach is better than traditional controllers. - Abstract: A new grid load frequency control approach is proposed for the doubly fed induction generator based wind power plants. The load frequency control issue in a power system is undergoing fundamental changes due to the rapidly growing amount of wind energy conversation system, and concentrating on maintaining generation-load balance and disturbance rejection. The prominent feature of the linear active disturbance rejection control approach is that the total disturbance can be estimated and then eliminated in real time. And thus, it is a feasible solution to deal with the load frequency control issue. In this paper, the application of the linear active disturbance rejection control approach in the load frequency control issue for a complex power system with wind energy conversation system based on doubly fed induction generator is investigated. The load frequency control issue is formulated as a decentralized multi-objective optimization control problem, the solution to which is solved by the hybrid particle swarm optimization technique. To show the effectiveness of the proposed control scheme, the robust performance testing based on Monte-Carlo approach is carried out. The performance superiority of the system with the proposed linear active disturbance rejection control approach over that with the traditional proportional integral and fuzzy-proportional integral-based controllers is validated by the simulation results

  20. Distributed Smart Grid Asset Control Strategies for Providing Ancillary Services

    Energy Technology Data Exchange (ETDEWEB)

    Kalsi, Karanjit [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zhang, Wei [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Lian, Jianming [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Marinovici, Laurentiu D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Moya, Christian [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Dagle, Jeffery E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2013-10-30

    With large-scale plans to integrate renewable generation driven mainly by state-level renewable portfolio requirements, more resources will be needed to compensate for the uncertainty and variability associated with intermittent generation resources. Distributed assets can be used to mitigate the concerns associated with renewable energy resources and to keep costs down. Under such conditions, performing primary frequency control using only supply-side resources becomes not only prohibitively expensive but also technically difficult. It is therefore important to explore how a sufficient proportion of the loads could assume a routine role in primary frequency control to maintain the stability of the system at an acceptable cost. The main objective of this project is to develop a novel hierarchical distributed framework for frequency based load control. The framework involves two decision layers. The top decision layer determines the optimal gain for aggregated loads for each load bus. The gains are computed using decentralized robust control methods, and will be broadcast to the corresponding participating loads every control period. The second layer consists of a large number of heterogeneous devices, which switch probabilistically during contingencies so that aggregated power change matches the desired amount according to the most recently received gains. The simulation results show great potential to enable systematic design of demand-side primary frequency control with stability guarantees on the overall power system. The proposed design systematically accounts for the interactions between the total load response and bulk power system frequency dynamics. It also guarantees frequency stability under a wide range of time varying operating conditions. The local device-level load response rules fully respect the device constraints (such as temperature setpoint, compressor time delays of HVACs, or arrival and departure of the deferrable loads), which are crucial for

  1. Design of a Load Following Controller for APR+ Nuclear Plants

    International Nuclear Information System (INIS)

    Lee, Sim Won; Kim, Jae Hwan; Kim, Dong Su; Na, Man Gyun; Yu, Keuk Jong

    2011-01-01

    The load-following operation of an APR+ nuclear plants is required to restrain the adjustment of boric acid concentration and to efficiently control the control rods for the flexibility of the operation. Especially, axial flux distribution disproportion that is usually caused by load-following operation in a reactor core induces xenon oscillation because the absorption cross-section of xenon is extremely large and its effects in a reactor are delayed by the iodine precursor. Rapid and smooth power maneuvering has its benefits in view of the economical and safe operation of reactors, so it is required that the controller is efficiently designed. Therefore, the load-following operation of an APR+ nuclear plants needs the ultimate automatic control and the advanced control method that satisfies the conditions such as the flexibility, safety and convenience. A model predictive control (MPC) method is applied to design an automatic load-following controller for the integrated thermal power level and axial shape index (ASI) control for an APR+ nuclear plants. Some tracking controllers use only the current tracking command. On the other hand, since MPC considers future commands in addition to the current tracking command, the MPC can achieve better tracking performance. Therefore, the MPC has been applied very much to the control of industrial process systems. The basic concept of the MPC is to solve an optimization problem for generating finite future control inputs at current time and to implement as the current control input only the first control input among the solutions of the finite time steps. At the next time step, the second control input is not implemented and the procedure to solve the optimization problem is then repeated. The power level and the ASI are controlled by the regulating control banks and part-strength control banks together with the automatic adjustment of boric acid concentration. The 3-dimensional MASTER code, which models the APR+ nuclear

  2. Design of a Load Following Controller for APR+ Nuclear Plants

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sim Won; Kim, Jae Hwan; Kim, Dong Su; Na, Man Gyun [Chosun University, Gwnagju (Korea, Republic of); Yu, Keuk Jong [Korea Hydro and Nuclear Power Co., Daejeon (Korea, Republic of)

    2011-08-15

    The load-following operation of an APR+ nuclear plants is required to restrain the adjustment of boric acid concentration and to efficiently control the control rods for the flexibility of the operation. Especially, axial flux distribution disproportion that is usually caused by load-following operation in a reactor core induces xenon oscillation because the absorption cross-section of xenon is extremely large and its effects in a reactor are delayed by the iodine precursor. Rapid and smooth power maneuvering has its benefits in view of the economical and safe operation of reactors, so it is required that the controller is efficiently designed. Therefore, the load-following operation of an APR+ nuclear plants needs the ultimate automatic control and the advanced control method that satisfies the conditions such as the flexibility, safety and convenience. A model predictive control (MPC) method is applied to design an automatic load-following controller for the integrated thermal power level and axial shape index (ASI) control for an APR+ nuclear plants. Some tracking controllers use only the current tracking command. On the other hand, since MPC considers future commands in addition to the current tracking command, the MPC can achieve better tracking performance. Therefore, the MPC has been applied very much to the control of industrial process systems. The basic concept of the MPC is to solve an optimization problem for generating finite future control inputs at current time and to implement as the current control input only the first control input among the solutions of the finite time steps. At the next time step, the second control input is not implemented and the procedure to solve the optimization problem is then repeated. The power level and the ASI are controlled by the regulating control banks and part-strength control banks together with the automatic adjustment of boric acid concentration. The 3-dimensional MASTER code, which models the APR+ nuclear

  3. Optimization Strategy for Economic Power Dispatch Utilizing Retired EV Batteries as Flexible Loads

    Directory of Open Access Journals (Sweden)

    Shubo Hu

    2018-06-01

    Full Text Available With the increasing penetration of new and renewable energy, incorporating variable adjustable power elements on the demand side is of particular interest. The utilization of batteries as flexible loads is a hot research topic. Lithium-ion batteries are key components in electric vehicles (EVs in terms of capital cost, mass and size. They are retired after around 5 years of service, but still retain up to 80% of their nominal capacity. Disposal of waste batteries will become a significant issue for the automotive industry in the years to come. This work proposes the use of the second life of these batteries as flexible loads to participate in the economic power dispatch. The characteristics of second life batteries (SLBs are varied and diverse, requiring a new optimization strategy for power dispatch at the system level. In this work, SLBs are characterized and their operating curves are obtained analytically for developing an economic power dispatch model involving wind farms and second life batteries. In addition, a dispatch strategy is developed to reduce the dispatch complex brought by the disperse spatial and time distribution of EVs and decrease the system operating cost by introducing incentive and penalty costs in regulating the EV performance. In theory, SLBs are utilized to reduce the peak-valley difference of power loads and to stabilize the power system. Test results based on a ten-unit power system have verified the effectiveness of the proposed dispatch model and the economic benefit of utilizing SLBs as flexible loads in power systems. This work may provide a viable solution to the disposal of waste batteries from EVs and to the stable operation of fluctuating power systems incorporating stochastic renewable energy.

  4. Modal space three-state feedback control for electro-hydraulic servo plane redundant driving mechanism with eccentric load decoupling.

    Science.gov (United States)

    Zhao, Jinsong; Wang, Zhipeng; Zhang, Chuanbi; Yang, Chifu; Bai, Wenjie; Zhao, Zining

    2018-06-01

    The shaking table based on electro-hydraulic servo parallel mechanism has the advantage of strong carrying capacity. However, the strong coupling caused by the eccentric load not only affects the degree of freedom space control precision, but also brings trouble to the system control. A novel decoupling control strategy is proposed, which is based on modal space to solve the coupling problem for parallel mechanism with eccentric load. The phenomenon of strong dynamic coupling among degree of freedom space is described by experiments, and its influence on control design is discussed. Considering the particularity of plane motion, the dynamic model is built by Lagrangian method to avoid complex calculations. The dynamic equations of the coupling physical space are transformed into the dynamic equations of the decoupling modal space by using the weighted orthogonality of the modal main mode with respect to mass matrix and stiffness matrix. In the modal space, the adjustments of the modal channels are independent of each other. Moreover, the paper discusses identical closed-loop dynamic characteristics of modal channels, which will realize decoupling for degree of freedom space, thus a modal space three-state feedback control is proposed to expand the frequency bandwidth of each modal channel for ensuring their near-identical responses in a larger frequency range. Experimental results show that the concept of modal space three-state feedback control proposed in this paper can effectively reduce the strong coupling problem of degree of freedom space channels, which verify the effectiveness of the proposed model space state feedback control strategy for improving the control performance of the electro-hydraulic servo plane redundant driving mechanism. Copyright © 2018 ISA. Published by Elsevier Ltd. All rights reserved.

  5. Robust control investigations for equipment loaded panels

    DEFF Research Database (Denmark)

    Aglietti, G.S.; Langley, R.S.; Rogers, E.

    1998-01-01

    This paper develops a modelling technique for equipment load panels which directly produces (adequate) models of the underlying dynamics on which to base robust controller design/evaluations. This technique is based on the use of the Lagrange's equations of motion and the resulting models...

  6. Effective use of proportional-integral controllers for stabilization and tuning of load-frequency control systems

    Energy Technology Data Exchange (ETDEWEB)

    Coelho, Carlos Alberto D [Escola Federal de Engenharia de Itajuba, MG (Brazil). Dept. de Eletronica

    1994-12-31

    In load-frequency control loops of electric power systems, the use of purely integral controllers to eliminate steady-state frequency deviations is a well established practice. However, the use of controllers which have only integral action always make transient behaviour worse, as compared to proportional controllers. Integral action for steady-state error elimination should be introduced in parallel with proportional action, thus forming a Proportional-Integral (PI) Controller. In this work a systematic procedure for including and setting of PI controllers in load-frequency control systems is suggested. An example is included, in which the procedure is illustrated, and a comparison between the result obtained with a PI controller and that obtained with a purely integral controller is made. It is verified that the PI controller, besides eliminating the steady-state frequency deviation, gives a better transient behaviour. (author) 5 refs., 6 figs.

  7. Investigating the reactivity controlled compression ignition (RCCI) combustion strategy in a natural gas/diesel fueled engine with a pre-chamber

    International Nuclear Information System (INIS)

    Salahi, Mohammad Mahdi; Esfahanian, Vahid; Gharehghani, Ayatallah; Mirsalim, Mostafa

    2017-01-01

    Highlights: • A novel combustion strategy, RCCI with a pre-chamber, is proposed and investigated. • The proposed strategy extends the RCCI operating range to use less intake air temperatures. • The new concept extends the RCCI operating range to use lower portions of the active fuel. • The proposed strategy is sensitive to engine load and is more efficient for high loads. - Abstract: Reactivity controlled compression ignition (RCCI) concept has been proven to be a promising combustion mode for the next generations of internal combustion engines. This strategy is still subject of extensive studies to overcome its operational limitations. In the present work, the effect of using a pre-chamber to extend some operating ranges in a RCCI engine is investigated using coupled multidimensional computational fluid dynamics (CFD) with detailed chemical kinetic mechanisms. To accomplish this, the combustion and flow field in a single cylinder engine with a pre-chamber, working in RCCI mode and fueled with natural gas/diesel are numerically modeled. Experimental data is used to validate the simulation results and then, combustion characteristics and engine emissions in some various operating regions, in terms of initial temperature, fuel equivalence ratio and portions of the two fuels are discussed. The results reveal that the proposed strategy provides the ability to extend the engine operating ranges to use lower intake temperatures, even to 50 K lower for some cases, and also using a larger portion of natural gas instead of diesel fuel. On the other hand, the new strategy could result in incomplete combustion and formation of related emissions in low loads, but for higher engine loads it shows better combustion characteristics.

  8. Study of load change control in PWRs using the methods of linear optimal control

    International Nuclear Information System (INIS)

    Yang, T.

    1983-01-01

    This thesis investigates the application of modern control theory to the problem of controlling load changes in PWR power plants. A linear optimal state feedback scheme resulting from linear optimal control theory with a quadratic cost function is reduced to a partially decentralized control system using mode preservation techniques. Minimum information transfer among major components of the plant is investigated to provide an adequate coordination, simple implementation, and a reliable control system. Two control approaches are proposed: servo and model following. Each design considers several information structures for performance comparison. Integrated output error has been included in the control systems to accommodate external and plant parameter disturbances. In addition, the cross limit feature, specific to certain modern reactor control systems, is considered in the study to prevent low pressure reactor trip conditions. An 11th order nonlinear model for the reactor and boiler is derived based on theoretical principles, and simulation tests are performed for 10% load change as an illustration of system performance

  9. Influences of load characteristics on impaired control of grip forces in patients with cerebellar damage.

    Science.gov (United States)

    Brandauer, B; Timmann, D; Häusler, A; Hermsdörfer, J

    2010-02-01

    Various studies showed a clear impairment of cerebellar patients to modulate grip force in anticipation of the loads resulting from movements with a grasped object. This failure corroborated the theory of internal feedforward models in the cerebellum. Cerebellar damage also impairs the coordination of multiple-joint movements and this has been related to deficient prediction and compensation of movement-induced torques. To study the effects of disturbed torque control on feedforward grip-force control, two self-generated load conditions with different demands on torque control-one with movement-induced and the other with isometrically generated load changes-were directly compared in patients with cerebellar degeneration. Furthermore the cerebellum is thought to be more involved in grip-force adjustment to self-generated loads than to externally generated loads. Consequently, an additional condition with externally generated loads was introduced to further test this hypothesis. Analysis of 23 patients with degenerative cerebellar damage revealed clear impairments in predictive feedforward mechanisms in the control of both self-generated load types. Besides feedforward control, the cerebellar damage also affected more reactive responses when the externally generated load destabilized the grip, although this impairment may vary with the type of load as suggested by control experiments. The present findings provide further support that the cerebellum plays a major role in predictive control mechanisms. However, this impact of the cerebellum does not strongly depend on the nature of the load and the specific internal forward model. Contributions to reactive (grip force) control are not negligible, but seem to be dependent on the physical characteristics of an externally generated load.

  10. Optimal control of anthracnose using mixed strategies.

    Science.gov (United States)

    Fotsa Mbogne, David Jaures; Thron, Christopher

    2015-11-01

    In this paper we propose and study a spatial diffusion model for the control of anthracnose disease in a bounded domain. The model is a generalization of the one previously developed in [15]. We use the model to simulate two different types of control strategies against anthracnose disease. Strategies that employ chemical fungicides are modeled using a continuous control function; while strategies that rely on cultivational practices (such as pruning and removal of mummified fruits) are modeled with a control function which is discrete in time (though not in space). For comparative purposes, we perform our analyses for a spatially-averaged model as well as the space-dependent diffusion model. Under weak smoothness conditions on parameters we demonstrate the well-posedness of both models by verifying existence and uniqueness of the solution for the growth inhibition rate for given initial conditions. We also show that the set [0, 1] is positively invariant. We first study control by impulsive strategies, then analyze the simultaneous use of mixed continuous and pulse strategies. In each case we specify a cost functional to be minimized, and we demonstrate the existence of optimal control strategies. In the case of pulse-only strategies, we provide explicit algorithms for finding the optimal control strategies for both the spatially-averaged model and the space-dependent model. We verify the algorithms for both models via simulation, and discuss properties of the optimal solutions. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Wind Turbine Load Mitigation based on Multivariable Robust Control and Blade Root Sensors

    International Nuclear Information System (INIS)

    Corcuera, A Díaz de; Pujana-Arrese, A; Ezquerra, J M; Segurola, E; Landaluze, J

    2014-01-01

    This paper presents two H ∞ multivariable robust controllers based on blade root sensors' information for individual pitch angle control. The wind turbine of 5 MW defined in the Upwind European project is the reference non-linear model used in this research work, which has been modelled in the GH Bladed 4.0 software package. The main objective of these controllers is load mitigation in different components of wind turbines during power production in the above rated control zone. The first proposed multi-input multi-output (MIMO) individual pitch H'' controller mitigates the wind effect on the tower side-to-side acceleration and reduces the asymmetrical loads which appear in the rotor due to its misalignment. The second individual pitch H'' multivariable controller mitigates the loads on the three blades reducing the wind effect on the bending flapwise and edgewise momentums in the blades. The designed H'' controllers have been validated in GH Bladed and an exhaustive analysis has been carried out to calculate fatigue load reduction on wind turbine components, as well as to analyze load mitigation in some extreme cases

  12. Control and load management of a fuel cell based hybrid system; Steuerung und Lademanagement eines brennstoffzellen-basierten Hybridsystems

    Energy Technology Data Exchange (ETDEWEB)

    Klausmann, Andreas

    2011-07-01

    Objective of this work is the development of a control for a hybrid electric power train. Initial point is an electric drive powered by a rechargeable battery. This battery shall be recharged during operation by a methanol-driven fuel cell. At this point it is not intended to deploy a direct methanol fuel cell but a combination of a methanol reformer generating hydrogen-rich gas and a high-temperature fuel cell (HTPEM-FC). This work covers the general strategy of operation like load cycles, standby phases etc., the reformer control and the fuel cell operation with a newly developed charge concept. While the basic research is done on a rapid prototyping system this work aims on porting the control system to an embedded platform. Here emphasis is put on the hardware independency of the control. The development of the reformer control contains the strategy for heating up the system with a minimum of electrical energy consumption, since this energy has to be supplied from the battery during the system start-up, increasing the minimum charge level of the battery required for an autarkic recharge. Unlike in common systems the reformer will be modulated according to the electric load and not vice versa, though the fuel cell serves as load sensor. Beside start-up and shutdown strategies the fuel cell control covers particularly the charge control. The electric load is assumed to be unknown, non-influenceable and unsteady. The charge control handles the charging of the battery under optimal utilization of the available hydrogen while avoiding an overload of the fuel cell caused by sudden load changes like powering up the drive. Therefore the common step-down circuit will be advanced so that all huge and heavy electronic components can be minimized or substituted by internal effects of battery and fuel cell. The fuel utilization will be feed back to the reformer control. After coupling of reformer and fuel cell control the system will be ported to an embedded control system

  13. Brushless DC motor speed control strategy of simulation research

    Directory of Open Access Journals (Sweden)

    Xiang Wen

    2017-01-01

    Full Text Available In view of the brushless DC motor speed regulation problem, an ideal control strategy is designed. Through the model and analysis of Brushless DC motor, the mathematical model of the brushless DC motor is obtained. By comparing three control strategies of PID control strategy, fuzzy control strategy and fuzzy PID control strategy, PID controller, fuzzy controller and fuzzy PID controller are designed respectively for simulation test. The simulation results show that the fuzzy PID controller has good control effect.

  14. Behind the Meter Grid Services: Intelligent Load Control

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Woohyun [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Katipamula, Srinivas [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Lutes, Robert G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Underhill, Ronald M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-11-15

    This report describes how the intelligent load control (ILC) algorithm can be implemented to achieve peak demand reduction while minimizing impacts on occupant comfort. The algorithm was designed to minimize the additional sensors and minimum configuration requirements to enable a scalable and cost-effective implementation for both large and small-/medium-sized commercial buildings. The ILC algorithm uses an analytic hierarchy process (AHP) to dynamically prioritize the available curtailable loads based on both quantitative (deviation of zone conditions from set point) and qualitative rules (types of zone). Although the ILC algorithm described in this report was highly tailored to work with rooftop units, it can be generalized for application to other building loads such as variable-air-volume (VAV) boxes and lighting systems.

  15. [Aedes aegypti control strategies: a review].

    Science.gov (United States)

    Zara, Ana Laura de Sene Amâncio; Santos, Sandra Maria Dos; Fernandes-Oliveira, Ellen Synthia; Carvalho, Roberta Gomes; Coelho, Giovanini Evelim

    2016-01-01

    to describe the main strategies to control Aedes aegypti, with emphasis on promising technological innovations for use in Brazil. this study is a non-systematic review of the literature. several technologies have been developed as alternatives in the control of Ae. aegypti, using different mechanisms of action, such as selective monitoring of the infestation, social interventions, dispersing insecticides, new biological control agents and molecular techniques for population control of mosquitoes, also considering the combination between them. Evolving technologies require evaluation of the effectiveness, feasibility and costs of implementation strategies as complementary to the actions already recommended by the National Program for Dengue Control. the integration of different compatible and effective vector control strategies, considering the available technologies and regional characteristics, appears to be a viable method to try to reduce the infestation of mosquitoes and the incidence of arbovirus transmitted by them.

  16. Functioning strategy study on control systems of large physical installations used with a digital computer

    International Nuclear Information System (INIS)

    Bel'man, L.B.; Lavrikov, S.A.; Lenskij, O.D.

    1975-01-01

    A criterion to evaluate the efficiency of a control system functioning of large physical installations by means of a control computer. The criteria are the object utilization factor and computer load factor. Different strategies of control system functioning are described, and their comparative analysis is made. A choice of such important parameters as sampling time and parameter correction time is made. A single factor to evaluate the system functioning efficiency is introduced and its dependence on the sampling interval value is given. Using diagrams attached, it is easy to find the optimum value of the sampling interval and the corresponding maximum value of the single efficiency factor proposed

  17. Working memory load and distraction: dissociable effects of visual maintenance and cognitive control.

    Science.gov (United States)

    Konstantinou, Nikos; Beal, Eleanor; King, Jean-Remi; Lavie, Nilli

    2014-10-01

    We establish a new dissociation between the roles of working memory (WM) cognitive control and visual maintenance in selective attention as measured by the efficiency of distractor rejection. The extent to which focused selective attention can prevent distraction has been shown to critically depend on the level and type of load involved in the task. High perceptual load that consumes perceptual capacity leads to reduced distractor processing, whereas high WM load that reduces WM ability to exert priority-based executive cognitive control over the task results in increased distractor processing (e.g., Lavie, Trends in Cognitive Sciences, 9(2), 75-82, 2005). WM also serves to maintain task-relevant visual representations, and such visual maintenance is known to recruit the same sensory cortices as those involved in perception (e.g., Pasternak & Greenlee, Nature Reviews Neuroscience, 6(2), 97-107, 2005). These findings led us to hypothesize that loading WM with visual maintenance would reduce visual capacity involved in perception, thus resulting in reduced distractor processing-similar to perceptual load and opposite to WM cognitive control load. Distractor processing was assessed in a response competition task, presented during the memory interval (or during encoding; Experiment 1a) of a WM task. Loading visual maintenance or encoding by increased set size for a memory sample of shapes, colors, and locations led to reduced distractor response competition effects. In contrast, loading WM cognitive control with verbal rehearsal of a random letter set led to increased distractor effects. These findings confirm load theory predictions and provide a novel functional distinction between the roles of WM maintenance and cognitive control in selective attention.

  18. Diagnostic system for process control at NPP Dukovany load follow

    International Nuclear Information System (INIS)

    Rubek, J.; Petruzela, I.

    1998-01-01

    The NPP Dukovany is being operated in the frequency control since 1996. In last year a project for the plant load follow has been developed. One part of the project is to install a diagnostic system for process control. At present the main control loops of the plant control system are regular tested after unit refuelling only. The functionality and control system parameter adjusting is tested by certificated procedures. This state is unsuitable in view of the plan load follow operation. The relevant operational modes are based on minimisation of influence on plant component life time and on achievement of planned unit parameters. Therefore it is necessary to provide testing of main control system parts in shorter time period. Mainly at time when the unit is really in load follow operation. The paper describes the diagnostic system for process control which will be at NPP Dukovany implemented. The principal of the system will be evaluation of real and expected changes of technological variables. The system utilises thermohydraulic relation among main technological variables and relation among controlled and manipulated variables. Outputs of the system will be used to operational staff support at the plant operation. It enables: determination of control system state, estimation and check of future control system state, early indication of the deviation of process from normal conditions, check of efficiency of operational staff intervention into plant control. The system gives the plant operator new information for the plant process control. Simultaneously the coupling of new system outputs on existing signalisation is solved. (author)

  19. Operation and control of a hybrid microgrid containing unbalanced and nonlinear loads

    Energy Technology Data Exchange (ETDEWEB)

    Shahnia, Farhad; Majumder, Ritwik; Ghosh, Arindam; Ledwich, Gerard; Zare, Firuz [School of Engineering, Queensland University of Technology, 2 George Street, Brisbane, Queensland 4001 (Australia)

    2010-08-15

    This paper shows how the power quality can be improved in a microgrid that is supplying a nonlinear and unbalanced load. The microgrid contains a hybrid combination of inertial and converter interfaced distributed generation units where a decentralized power sharing algorithm is used to control its power management. One of the distributed generators in the microgrid is used as a power quality compensator for the unbalanced and harmonic load. The current reference generation for power quality improvement takes into account the active and reactive power to be supplied by the micro-source which is connected to the compensator. Depending on the power requirement of the nonlinear load, the proposed control scheme can change modes of operation without any external communication interfaces. The compensator can operate in two modes depending on the entire power demand of the unbalanced nonlinear load. The proposed control scheme can even compensate system unbalance caused by the single-phase micro-sources and load changes. The efficacy of the proposed power quality improvement control and method in such a microgrid is validated through extensive simulation studies using PSCAD/EMTDC software with detailed dynamic models of the micro-sources and power electronic converters. (author)

  20. Real Time Monitoring and Supervisory Control of Distribution Load Based on Generic Load Allocation: A Smart Grid Solution

    Directory of Open Access Journals (Sweden)

    Anwer Ahmed Memon

    2014-04-01

    Full Text Available Our work is the small part of the smart grid system. This is regarding the check and balance of power consumption at the consumer level. It is a well known fact that the consumers are allocated a fixed load according to their requirement at the time of application for the electricity connection. When the consumer increases its load and does not inform the power company, the result is the overloading of the system. This paper presents a solution regarding distribution and load allocation to each customer. If the customer uses power greater than the load allocated, further power is not provided and consequently that appliance is not turned on unless the total load must not be decreased than the allocated load. This is achieved by designing a processor controlled system that measures the power on main line and also the power taken by each device. Now when a device is turned on, its power is measured by the controller and compares it with the main line power, and when the device consumes some power consequently main line power will also be increased thus this main line power is monitored and if it exceeds particular limit that device is turned off through its relay

  1. Real time monitoring and supervisory control of distribution load based on generic load allocation: a smart grid solution

    International Nuclear Information System (INIS)

    Memon, A.W.; Memon, Z.A.; Aamir, R.R.

    2014-01-01

    Our work is the small part of the smart grid system. This is regarding the check and balance of power consumption at the consumer level. It is a well known fact that the consumers are allocated a fixed load according to their requirement at the time of application for the electricity connection. When the consumer increases its load and does not inform the power company, the result is the overloading of the system. This paper presents a solution regarding distribution and load allocation to each customer. If the customer uses power greater than the load allocated, further power is not provided and consequently that appliance is not turned on unless the total load must not be decreased than the allocated load. This is achieved by designing a processor controlled system that measures the power on main line and also the power taken by each device. Now when a device is turned on, its power is measured by the controller and compares it with the main line power, and when the device consumes some power consequently main line power will also be increased thus this main line power is monitored and if it exceeds particular limit that device is turned off through its relay. (author)

  2. Individual pitch control of NREL 5MW wind turbine blade for load reduction

    International Nuclear Information System (INIS)

    La, Yo Han; Nam, Yoon Su; Hoon, Son Jae

    2012-01-01

    As the size of a wind turbine increases, the rotor diameter increases. Rotor blades experience mechanical loads caused by the wind shear and the tower shadow effect. These mechanical loads reduce the life of the wind turbine. Therefore, with increasing size of the wind turbine, wind turbine control system design for the mitigation of mechanical loads is important. In this study, Individual Pitch Control in introduced for reducing the mechanical loads of rotor blades, and a simulation for IPC performance verification is discussed

  3. Momentum management strategy during Space Station buildup

    Science.gov (United States)

    Bishop, Lynda; Malchow, Harvey; Hattis, Philip

    1988-01-01

    The use of momentum storage devices to control effectors for Space Station attitude control throughout the buildup sequence is discussed. Particular attention is given to the problem of providing satisfactory management of momentum storage effectors throughout buildup while experiencing variable torque loading. Continuous and discrete control strategies are compared and the effects of alternative control moment gyro strategies on peak momentum storage requirements and on commanded maneuver characteristics are described.

  4. Engineering to Control Noise, Loading, and Optimal Operating Points

    International Nuclear Information System (INIS)

    Mitchell R. Swartz

    2000-01-01

    Successful engineering of low-energy nuclear systems requires control of noise, loading, and optimum operating point (OOP) manifolds. The latter result from the biphasic system response of low-energy nuclear reaction (LENR)/cold fusion systems, and their ash production rate, to input electrical power. Knowledge of the optimal operating point manifold can improve the reproducibility and efficacy of these systems in several ways. Improved control of noise, loading, and peak production rates is available through the study, and use, of OOP manifolds. Engineering of systems toward the OOP-manifold drive-point peak may, with inclusion of geometric factors, permit more accurate uniform determinations of the calibrated activity of these materials/systems

  5. Control Law Design for Propofol Infusion to Regulate Depth of Hypnosis: A Nonlinear Control Strategy

    Directory of Open Access Journals (Sweden)

    Ali Khaqan

    2016-01-01

    Full Text Available Maintaining the depth of hypnosis (DOH during surgery is one of the major objectives of anesthesia infusion system. Continuous administration of Propofol infusion during surgical procedures is essential but increases the undue load of an anesthetist in operating room working in a multitasking setup. Manual and target controlled infusion (TCI systems are not good at handling instabilities like blood pressure changes and heart rate variability arising due to interpatient variability. Patient safety, large interindividual variability, and less postoperative effects are the main factors to motivate automation in anesthesia. The idea of automated system for Propofol infusion excites the control engineers to come up with a more sophisticated and safe system that handles optimum delivery of drug during surgery and avoids postoperative effects. In contrast to most of the investigations with linear control strategies, the originality of this research work lies in employing a nonlinear control technique, backstepping, to track the desired hypnosis level of patients during surgery. This effort is envisioned to unleash the true capabilities of this nonlinear control technique for anesthesia systems used today in biomedical field. The working of the designed controller is studied on the real dataset of five patients undergoing surgery. The controller tracks the desired hypnosis level within the acceptable range for surgery.

  6. EPR: High load variation performances with the 'Tmode' core control

    International Nuclear Information System (INIS)

    Grossetete, A.

    2008-01-01

    The load variation performances on a PWR are directly linked to the core control design. This design is mainly characterized by the definition of the control rod banks and the way to both perform the banks movements and to modify the core boron concentration by injection of boric acid or water. The following paper presents the principles of the T mode, the new fully automatic core control mode for the EPR which provides high performance in terms of maneuverability and optimizes the effluents. First, the paper describes the division of the control rods into two control banks (Pbank for temperature and Hbank for power distribution). Then typical movements of these banks during power changes are shown. Then, the principle of the 3 control loops (Tave, AO, Pmax), used to obtain these desired control rod movements, is given. Finally, a load following transient simulation is presented. (authors)

  7. EPR: high load variation performances with the 'TMODE' core control

    International Nuclear Information System (INIS)

    Pairot, Frederic

    2008-01-01

    The load variation performances on a PWR are directly linked to the core control design. This design is mainly characterized by the definition of the control rod banks and the way to both perform the banks movements and to modify the core boron concentration by injection of boric acid or water. The following paper presents the principles of the T mode, the new fully automatic core control mode for the EPR which provides high performance in terms of maneuverability and optimizes the effluents. First, the paper describes the division of the control rods into two control banks (Pbank for temperature and Hbank for power distribution). Then typical movements of these banks during power changes are shown. Then, the principle of the 3 control loops (Tave, AO, Pmax), used to obtain these desired control rod movements, is given. Finally, a load following transient simulation is presented. (author)

  8. Speed response of brushless DC motor using fuzzy PID controller under varying load condition

    Directory of Open Access Journals (Sweden)

    Akash Varshney

    2017-09-01

    Full Text Available The increasing trend towards usage of precisely controlled, high torque, efficient and low noise motors for dedicated applications has attracted the attention of researcher in Brushless DC (BLDC motors. BLDC motors can act as an acceptable alternative to the conventional motors like Induction Motors, Switched Reluctance Motors etc. This paper presents a detailed study on the performance of a BLDC motor supplying different types of loads, and at the same time, deploying different control techniques. An advance Fuzzy PID controller is compared with the commonly used PID controller. The load variations considered are of the most common types, generally encountered in practice. A comparison has been carried out in this paper by observing the dynamic speed response of motor at the time of application as well as at the time of removal of the load. The BLDC motors suffer from a major drawback of having jerky behaviour at the time of load removal. The study reveals that irrespective of the type of controller used, the gradual load variation produces better results as against sudden load variations. It is further observed that in addition to other dynamic features, the jerks produced at the time of load removal also get improved to a large extent with Fuzzy PID controller.The speed torque characteristics unraveled the fact that the jerks are minimum at the time of gradual load removal with Fuzzy PID controller in place. An attempt has been made to define these jerks by ‘Perturbation Window’.

  9. Least loaded and route fragmentation aware RSA strategies for elastic optical networks

    Science.gov (United States)

    Batham, Deepak; Yadav, Dharmendra Singh; Prakash, Shashi

    2017-12-01

    Elastic optical networks (EONs) provide flexibility to assign wide range of spectral resources to the connection requests. In this manuscript, we address two issues related to spectrum assignment in EONs: the non uniform spectrum assignment along different links of the route and the spectrum fragmentation in the network. To address these issues, two routing and spectrum assignment (RSA) strategies have been proposed: Least Loaded RSA (LLRSA) and Route Fragmentation Aware RSA (RFARSA). The LLRSA allocates spectrum homogeneously along different links in the network, where as RFARSA accords priority to the routes which are less fragmented. To highlight the salient features of the two strategies, two new metrics, route fragmentation index (RFI) and standard deviation (SD) are introduced. RFI is defined as the ratio of non-contiguous FSs to the total available free FSs on the route, and SD relates to the measure of non-uniformity in the allocation of resources on the links in the network. A simulation program has been developed to evaluate the performance of the proposed (LLRSA and RFARSA) strategies, and the existing strategies of shortest path RSA (SPRSA) and spectrum compactness based defragmentation (SCD) strategies, on the metric of RFI, bandwidth blocking probability (BBP), network capacity utilized, and SD. The variation in the metrics on the basis of number of requests and the bandwidth (number of FSs) requested has been studied. It has been conclusively established that the proposed strategies (LLRSA and RFARSA) outperform the existing strategies in terms of all the metrics.

  10. Force Control Strategies in Hydraulically Actuated Legged Robots

    Directory of Open Access Journals (Sweden)

    Hector Montes

    2016-03-01

    Full Text Available In this contribution, several strategies of force control have been proposed to be implemented and evaluated in ROBOCLIMBER, a quadruped robot of large dimensions. A first group of strategies proposed in this paper is based on impedance control, which is intended to adapt the foot-ground contact forces according to the experimentally specified damping ratio and the undamped natural frequency. A second control strategy of interest for many practical cases is called the parallel force/position control, which has one inner loop position control and two external control loops, one of force and another of position. A third group of control strategies is the posture stabilization for ROBOCLIMBER using the feedback of the ZMP calculation and the position of its legs. Finally, a control strategy for the control of a quasi-static gait using ZMP feedback is proposed and tested by simulation.

  11. Fuel loading and control rod patterns optimization in a BWR using tabu search

    International Nuclear Information System (INIS)

    Castillo, Alejandro; Ortiz, Juan Jose; Montes, Jose Luis; Perusquia, Raul

    2007-01-01

    This paper presents the QuinalliBT system, a new approach to solve fuel loading and control rod patterns optimization problem in a coupled way. This system involves three different optimization stages; in the first one, a seed fuel loading using the Haling principle is designed. In the second stage, the corresponding control rod pattern for the previous fuel loading is obtained. Finally, in the last stage, a new fuel loading is created, starting from the previous fuel loading and using the corresponding set of optimized control rod patterns. For each stage, a different objective function is considered. In order to obtain the decision parameters used in those functions, the CM-PRESTO 3D steady-state reactor core simulator was used. Second and third stages are repeated until an appropriate fuel loading and its control rod pattern are obtained, or a stop criterion is achieved. In all stages, the tabu search optimization technique was used. The QuinalliBT system was tested and applied to a real BWR operation cycle. It was found that the value for k eff obtained by QuinalliBT was 0.0024 Δk/k greater than that of the reference cycle

  12. Load flow analysis for variable speed offshore wind farms

    DEFF Research Database (Denmark)

    Chen, Zhe; Zhao, Menghua; Blaabjerg, Frede

    2009-01-01

    factors such as the different wind farm configurations, the control of wind turbines and the power losses of pulse width modulation converters are considered. The DC/DC converter model is proposed and integrated into load flow algorithm by modifying the Jacobian matrix. Two iterative methods are proposed...... and integrated into the load flow algorithm: one takes into account the control strategy of converters and the other considers the power losses of converters. In addition, different types of variable speed wind turbine systems with different control methods are investigated. Finally, the method is demonstrated......A serial AC-DC integrated load flow algorithm for variable speed offshore wind farms is proposed. It divides the electrical system of a wind farm into several local networks, and different load flow methods are used for these local networks sequentially. This method is fast, more accurate, and many...

  13. Optimized Power Dispatch in Wind Farms for Power Maximizing Considering Fatigue Loads

    DEFF Research Database (Denmark)

    Zhang, Baohua; N. Soltani, Mohsen; Hu, Weihao

    2018-01-01

    Wake effects in a wind farm (WF) include the wind velocity deficit and added turbulence. The wind velocity deficit may bring significant loss of the wind power and the added turbulence may cause extra fatigue load on the wind turbines (WTs). Inclusion of the wake effects in the wind farm control...... at a series of turbulence intensity, mean wind speed and active power reference to form a lookup table, which is used for the WF control. The proposed strategy is compared with WT MPPT control strategy and WF MPPT control strategy. The simulation results show the effectiveness of the proposed strategy....

  14. Minimum Thrust Load Control for Floating Wind Turbine

    DEFF Research Database (Denmark)

    Christiansen, Søren; Bak, Thomas; Knudsen, Torben

    2012-01-01

    — Offshore wind energy capitalizes on the higher and less turbulent wind at sea. Shallow water sites are profitable for deployment of monopile wind turbines at water depths of up to 30 meters. Beyond 30 meters, the wind is even stronger and less turbulent. At these depths, floating wind turbines be...... and power stability when using the new control strategy.......— Offshore wind energy capitalizes on the higher and less turbulent wind at sea. Shallow water sites are profitable for deployment of monopile wind turbines at water depths of up to 30 meters. Beyond 30 meters, the wind is even stronger and less turbulent. At these depths, floating wind turbines...... presents a new minimum thrust control strategy capable of stabilizing a floating wind turbine. The new control strategy explores the freedom of variable generator speed above rated wind speed. A comparison to the traditional constant speed strategy, shows improvements in structural fore-aft oscillations...

  15. Modification of the algorithm for steam turbine control under loading drop

    International Nuclear Information System (INIS)

    Nikitin, Yu.V.; Mirnyj, V.A.; Gritsenko, V.N.; Nesterov, L.V.

    1989-01-01

    Problem related to powerful steam turbine control in case of emergency loading drop is considered. Two laws of control creating conditions for qualitative operation of control system under conditions considered are compared. The system of turbine control comprises the turbine major actuating mechanisms (electrohydraulic transducer, high-pressure servomotor, cut-off slide valve) actuating mechanisms of pulse discharge channel (low-pressure servomotor cut-off slide valve, low-pressure servomotor) and regulator. The frequency of the turbine rotor rotation is the parameter to be controlled in the mode of loading drop. The algorithms considered are based on linear variant of the optimal control theory. One of them is realized in electrohydraulic system of the K-750-65/3000 turbine control at the Ignalinsk NPP

  16. DACS II - A distributed thermal/mechanical loads data acquisition and control system

    Science.gov (United States)

    Zamanzadeh, Behzad; Trover, William F.; Anderson, Karl F.

    1987-01-01

    A distributed data acquisition and control system has been developed for the NASA Flight Loads Research Facility. The DACS II system is composed of seven computer systems and four array processors configured as a main computer system, three satellite computer systems, and 13 analog input/output systems interconnected through three independent data networks. Up to three independent heating and loading tests can be run concurrently on different test articles or the entire system can be used on a single large test such as a full scale hypersonic aircraft. Thermal tests can include up to 512 independent adaptive closed loop control channels. The control system can apply up to 20 MW of heating to a test specimen while simultaneously applying independent mechanical loads. Each thermal control loop is capable of heating a structure at rates of up to 150 F per second over a temperature range of -300 to +2500 F. Up to 64 independent mechanical load profiles can be commanded along with thermal control. Up to 1280 analog inputs monitor temperature, load, displacement and strain on the test specimens with real time data displayed on up to 15 terminals as color plots and tabular data displays. System setup and operation is accomplished with interactive menu-driver displays with extensive facilities to assist the users in all phases of system operation.

  17. Loads as a Resource: Frequency Responsive Demand

    Energy Technology Data Exchange (ETDEWEB)

    Kalsi, Karanjit [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Williams, Tess L. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Marinovici, Laurentiu D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Elizondo, Marcelo A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Lian, Jianming [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-11-30

    Demand-side frequency control can complement traditional generator controls to maintain the stability of large electric systems in the face of rising uncertainty and variability associated with renewable energy resources. This report presents a hierarchical frequency-based load control strategy that uses a supervisor to flexibly adjust control gains that a population of end-use loads respond to in a decentralized manner to help meet the NERC BAL-003-1 frequency response standard at both the area level and interconnection level. The load model is calibrated and used to model populations of frequency-responsive water heaters in a PowerWorld simulation of the U.S. Western Interconnection (WECC). The proposed design is implemented and demonstrated on physical water heaters in a laboratory setting. A significant fraction of the required frequency response in the WECC could be supplied by electric water heaters alone at penetration levels of less than 15%, while contributing to NERC requirements at the interconnection and area levels.

  18. 40 CFR 52.2088 - Control strategy: Ozone.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Ozone. 52.2088... strategy: Ozone. (a) Revisions to the State Implementation Plan submitted by the Rhode Island Department of... revised text is set forth as follows: § 52.2088 Control strategy: Ozone. (c) Determination of Attainment...

  19. Control of the low-load region in partially premixed combustion

    Science.gov (United States)

    Ingesson, Gabriel; Yin, Lianhao; Johansson, Rolf; Tunestal, Per

    2016-09-01

    Partially premixed combustion (PPC) is a low temperature, direct-injection combustion concept that has shown to give promising emission levels and efficiencies over a wide operating range. In this concept, high EGR ratios, high octane-number fuels and early injection timings are used to slow down the auto-ignition reactions and to enhance the fuel and are mixing before the start of combustion. A drawback with this concept is the combustion stability in the low-load region where a high octane-number fuel might cause misfire and low combustion efficiency. This paper investigates the problem of low-load PPC controller design for increased engine efficiency. First, low-load PPC data, obtained from a multi-cylinder heavy- duty engine is presented. The data shows that combustion efficiency could be increased by using a pilot injection and that there is a non-linearity in the relation between injection and combustion timing. Furthermore, intake conditions should be set in order to avoid operating points with unfavourable global equivalence ratio and in-cylinder temperature combinations. Model predictive control simulations were used together with a calibrated engine model to find a gas-system controller that fulfilled this task. The findings are then summarized in a suggested engine controller design. Finally, an experimental performance evaluation of the suggested controller is presented.

  20. A Parallel Energy-Sharing Control Strategy for Fuel Cell Hybrid Vehicle

    Directory of Open Access Journals (Sweden)

    Nik Rumzi Nik Idris

    2011-08-01

    Full Text Available This paper presents a parallel energy-sharing control strategy for the application of fuel cell hybrid vehicles (FCHVs. The hybrid source discussed consists of a fuel cells (FCs generator and energy storage units (ESUs which composed by the battery and ultracapacitor (UC modules. A direct current (DC bus is used to interface between the energy sources and the electric vehicles (EV propulsion system (loads. Energy sources are connected to the DC bus using of power electronics converters. A total of six control loops are designed in the supervisory system in order to regulate the DC bus voltage, control of current flow and to monitor the state of charge (SOC of each energy storage device at the same time. Proportional plus integral (PI controllers are employed to regulate the output from each control loop referring to their reference signals. The proposed energy control system is simulated in MATLAB/Simulink environment. Results indicated that the proposed parallel energy-sharing control system is capable to provide a practical hybrid vehicle in respond to the vehicle traction response and avoids the FC and battery from overstressed at the same time.

  1. Engine combustion control at low loads via fuel reactivity stratification

    Science.gov (United States)

    Reitz, Rolf Deneys; Hanson, Reed M; Splitter, Derek A; Kokjohn, Sage L

    2014-10-07

    A compression ignition (diesel) engine uses two or more fuel charges during a combustion cycle, with the fuel charges having two or more reactivities (e.g., different cetane numbers), in order to control the timing and duration of combustion. By appropriately choosing the reactivities of the charges, their relative amounts, and their timing, combustion can be tailored to achieve optimal power output (and thus fuel efficiency), at controlled temperatures (and thus controlled NOx), and with controlled equivalence ratios (and thus controlled soot). At low load and no load (idling) conditions, the aforementioned results are attained by restricting airflow to the combustion chamber during the intake stroke (as by throttling the incoming air at or prior to the combustion chamber's intake port) so that the cylinder air pressure is below ambient pressure at the start of the compression stroke.

  2. Engine combustion control at low loads via fuel reactivity stratification

    Energy Technology Data Exchange (ETDEWEB)

    Reitz, Rolf Deneys; Hanson, Reed M.; Splitter, Derek A.; Kokjohn, Sage

    2017-12-26

    A compression ignition (diesel) engine uses two or more fuel charges during a combustion cycle, with the fuel charges having two or more reactivities (e.g., different cetane numbers), in order to control the timing and duration of combustion. By appropriately choosing the reactivities of the charges, their relative amounts, and their timing, combustion can be tailored to achieve optimal power output (and thus fuel efficiency), at controlled temperatures (and thus controlled NOx), and with controlled equivalence ratios (and thus controlled soot). At low load and no load (idling) conditions, the aforementioned results are attained by restricting airflow to the combustion chamber during the intake stroke (as by throttling the incoming air at or prior to the combustion chamber's intake port) so that the cylinder air pressure is below ambient pressure at the start of the compression stroke.

  3. Ibuprofen-loaded poly(lactic-co-glycolic acid films for controlled drug release

    Directory of Open Access Journals (Sweden)

    Pang JM

    2011-04-01

    Full Text Available Jianmei Pang1, Yuxia Luan1, Feifei Li1, Xiaoqing Cai1, Jimin Du2, Zhonghao Li31School of Pharmaceutical Science, Shandong University, Jinan, Shandong Province, PR China; 2School of Chemistry and Chemical Engineering, Anyang Normal University, Henan Province, PR China; 3School of Materials Science and Engineering, Shandong University, Jinan, Shandong Province, PR ChinaAbstract: Ibuprofen- (IBU loaded biocompatible poly(lactic-co-glycolic acid (PLGA films were prepared by spreading polymer/ibuprofen solution on the nonsolvent surface. By controlling the weight ratio of drug and polymer, different drug loading polymer films can be obtained. The synthesized ibuprofen-loaded PLGA films were characterized with scanning electron microscopy, powder X-ray diffraction, and differential scanning calorimetry. The drug release behavior of the as-prepared IBU-loaded PLGA films was studied to reveal their potential application in drug delivery systems. The results show the feasibility of the as-obtained films for controlling drug release. Furthermore, the drug release rate of the film could be controlled by the drug loading content and the release medium. The development of a biodegradable ibuprofen system, based on films, should be of great interest in drug delivery systems.Keywords: ibuprofen, controlled release, poly(lactic-co-glycolic acid, films

  4. Combined Two-Stage Stochastic Programming and Receding Horizon Control Strategy for Microgrid Energy Management Considering Uncertainty

    Directory of Open Access Journals (Sweden)

    Zhongwen Li

    2016-06-01

    Full Text Available Microgrids (MGs are presented as a cornerstone of smart grids. With the potential to integrate intermittent renewable energy sources (RES in a flexible and environmental way, the MG concept has gained even more attention. Due to the randomness of RES, load, and electricity price in MG, the forecast errors of MGs will affect the performance of the power scheduling and the operating cost of an MG. In this paper, a combined stochastic programming and receding horizon control (SPRHC strategy is proposed for microgrid energy management under uncertainty, which combines the advantages of two-stage stochastic programming (SP and receding horizon control (RHC strategy. With an SP strategy, a scheduling plan can be derived that minimizes the risk of uncertainty by involving the uncertainty of MG in the optimization model. With an RHC strategy, the uncertainty within the MG can be further compensated through a feedback mechanism with the lately updated forecast information. In our approach, a proper strategy is also proposed to maintain the SP model as a mixed integer linear constrained quadratic programming (MILCQP problem, which is solvable without resorting to any heuristics algorithms. The results of numerical experiments explicitly demonstrate the superiority of the proposed strategy for both island and grid-connected operating modes of an MG.

  5. Study on load levelling by means of the control of air conditioner operation; Kuchoki kado seigyo ni yoru fuka heijunka ni kansuru ichikosatsu

    Energy Technology Data Exchange (ETDEWEB)

    Sasaki, H. [Hiroshima University, Hiroshima (Japan); Sadakuni, S. [Japan Broadcasting Corp., Tokyo (Japan)

    1995-04-20

    The recent drastic increase in the number of air conditioners has caused sharp and narrow peaks in summer seasons due to the inherent temperature sensitive characteristics. The authors proposed to reduce the peak power demand by controlling air conditioner operations, verifying its effectiveness on peak demand clipping. However, the former study has shortcomings in that any qualitative treatment of room temperatures or pleasant feeling was not attempted and it did not provide a way of assessing peak demand clipping in a power system as a whole. In this paper, we shall first propose a new control method that can compromise pleasant feeling and reduction in power demand. Although air conditioners are used to pursue `pleasant feeling`, this contradicts to reduce power consumption and further more the concept of `pleasant feeling` is very vague. Hence, `Weber-Fechner`s law` is utilized to quantify the pleasant feeling which is treated as fuzzy quantity. Fuzzy co-ordination method is used to compromise power demand curtailment and pleasantness. In the second part of this paper, we shall propose an approach of assessing the amount of peak load clipping when the newly proposed control strategy is adopted in a real size power system: A decrease in the required generation capacity is estimated provided that the Loss of Load Probability (LOLP) is maintained at the same level before and after the application of the new control strategy. The reduction can be regarded as a dividend of load management. 5 refs., 9 figs., 5 tabs.

  6. Experimental Results of a DC Bus Voltage Level Control for a Load-Controlled Marine Current Energy Converter

    Directory of Open Access Journals (Sweden)

    Johan Forslund

    2015-05-01

    Full Text Available This paper investigates three load control methods for a  marine current energy converter using a vertical axis current  turbine (VACT mounted on a permanent magnet synchronous generator  (PMSG. The three cases are; a fixed AC load, a fixed pulse width  modulated (PWM DC load and DC bus voltage control of a DC  load. Experimental results show that the DC bus voltage control  reduces the variations of rotational speed by a factor of 3.5 at the cost  of slightly increased losses in the generator and transmission lines.  For all three cases, the tip speed ratio \\(\\lambda\\ can be kept close to  the expected \\(\\lambda_{opt}\\. The power coefficient is estimated to be  0.36 at \\(\\lambda_{opt}\\; however, for all three cases, the average  extracted power was about \\(\\sim 19\\\\%. A maximum power point  tracking (MPPT system, with or without water velocity measurement,  could increase the average extracted power.

  7. Load speed regulation in compliant mechanical transmission systems using feedback and feedforward control actions.

    Science.gov (United States)

    Raul, P R; Dwivedula, R V; Pagilla, P R

    2016-07-01

    The problem of controlling the load speed of a mechanical transmission system consisting of a belt-pulley and gear-pair is considered. The system is modeled as two inertia (motor and load) connected by a compliant transmission. If the transmission is assumed to be rigid, then using either the motor or load speed feedback provides the same result. However, with transmission compliance, due to belts or long shafts, the stability characteristics and performance of the closed-loop system are quite different when either motor or load speed feedback is employed. We investigate motor and load speed feedback schemes by utilizing the singular perturbation method. We propose and discuss a control scheme that utilizes both motor and load speed feedback, and design an adaptive feedforward action to reject load torque disturbances. The control algorithms are implemented on an experimental platform that is typically used in roll-to-roll manufacturing and results are shown and discussed. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.

  8. Optimal control of a fuel cell/wind/PV/grid hybrid system with thermal heat pump load

    CSIR Research Space (South Africa)

    Sichilalu, S

    2016-10-01

    Full Text Available This paper presents an optimal energy management strategy for a grid-tied photovoltaic–wind-fuel cell hybrid power supply system. The hybrid system meets the load demand consisting of an electrical load and a heat pump water heater supplying thermal...

  9. Proportional Load Sharing and Stability of DC Microgrid with Distributed Architecture Using SM Controller

    Directory of Open Access Journals (Sweden)

    Muhammad Rashad

    2018-01-01

    Full Text Available DC microgrids look attractive in distribution systems due to their high reliability, high efficiency, and easy integration with renewable energy sources. The key objectives of the DC microgrid include proportional load sharing and precise voltage regulation. Droop controllers are based on decentralized control architectures which are not effective in achieving these objectives simultaneously due to the voltage error and load power variation. A centralized controller can achieve these objectives using a high speed communication link. However, it loses reliability due to the single point failure. Additionally, these controllers are realized through proportional integral (PI controllers which cannot ensure load sharing and stability in all operating conditions. To address limitations, a distributed architecture using sliding mode (SM controller utilizing low bandwidth communication is proposed for DC microgrids in this paper. The main advantages are high reliability, load power sharing, and precise voltage regulation. Further, the SM controller shows high robustness, fast dynamic response, and good stability for large load variations. To analyze the stability and dynamic performance, a system model is developed and its transversality, reachability, and equivalent control conditions are verified. Furthermore, the dynamic behavior of the modeled system is investigated for underdamped and critically damped responses. Detailed simulations are carried out to show the effectiveness of the proposed controller.

  10. Cognitive task load in a naval ship control centre: from identification to prediction.

    Science.gov (United States)

    Grootjen, M; Neerincx, M A; Veltman, J A

    Deployment of information and communication technology will lead to further automation of control centre tasks and an increasing amount of information to be processed. A method for establishing adequate levels of cognitive task load for the operators in such complex environments has been developed. It is based on a model distinguishing three load factors: time occupied, task-set switching, and level of information processing. Application of the method resulted in eight scenarios for eight extremes of task load (i.e. low and high values for each load factor). These scenarios were performed by 13 teams in a high-fidelity control centre simulator of the Royal Netherlands Navy. The results show that the method provides good prediction of the task load that will actually appear in the simulator. The model allowed identification of under- and overload situations showing negative effects on operator performance corresponding to controlled experiments in a less realistic task environment. Tools proposed to keep the operator at an optimum task load are (adaptive) task allocation and interface support.

  11. Development of Electronic Load Controllers for Free-Piston Stirling Convertors Aided by Stirling Simulation Model

    Science.gov (United States)

    Regan, Timothy F.

    2004-01-01

    The free-piston Stirling convertor end-to-end modeling effort at the NASA Glenn Research Center has produced a software-based test bed in which free-piston Stirling convertors can be simulated and evaluated. The simulation model includes all the components of the convertor: the Stirling cycle engine, heat source, linear alternator, controller, and load. So far, it has been used in evaluating the performance of electronic controller designs. Three different controller design concepts were simulated using the model: 1) Controllers with parasitic direct current loading. 2) Controllers with parasitic alternating current loading. 3) Controllers that maintain a reference current. The free-piston Stirling convertor is an electromechanical device that operates at resonance. It is the function of the electronic load controller to ensure that the electrical load seen by the machine is always great enough to keep the amplitude of the piston and alternator oscillation at the rated value. This is done by regulating the load on the output bus. The controller monitors the instantaneous voltage, regulating it by switching loads called parasitic loads onto the bus whenever the bus voltage is too high and removing them whenever the voltage is too low. In the first type of controller, the monitor-ing and switching are done on the direct-current (dc) bus. In the second type, the alternating current bus is used. The model allows designers to test a controller concept before investing time in hardware. The simulation code used to develop the model also offers detailed models of digital and analog electronic components so that the resulting designs are realistic enough to translate directly into hardware circuits.

  12. Disruptions in ITER and strategies for their control and mitigation

    Energy Technology Data Exchange (ETDEWEB)

    Lehnen, M., E-mail: michael.lehnen@iter.org [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul Lez Durance (France); Aleynikova, K.; Aleynikov, P.B.; Campbell, D.J. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul Lez Durance (France); Drewelow, P. [Max-Planck-Institut für Plasmaphysik, Greifswald branch, EURATOM Ass., D-17491 Greifswald (Germany); Eidietis, N.W. [General Atomics, P.O. Box 85608, San Diego, CA 92186-5608 (United States); Gasparyan, Yu. [National Research Nuclear University MEPhI (Moscow Engineering Physics Institute), Kashirskoe sh. 31, Moscow 115409 (Russian Federation); Granetz, R.S. [MIT Plasma Science and Fusion Center, Cambridge, MA 02139 (United States); Gribov, Y. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul Lez Durance (France); Hartmann, N. [Forschungszentrum Jülich GmbH, Institute of Energy and Climate Research—Plasma Physics, Association EURATOM-FZJ, Trilateral Euregio Cluster, 52425 Jülich (Germany); Hollmann, E.M. [University of California-San Diego, La Jolla, CA 92093 (United States); Izzo, V.A. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul Lez Durance (France); Jachmich, S. [Laboratory for Plasma Physics, ERM/KMS, Association EURATOM – Belgian State, B-1000 Brussels (Belgium); Kim, S.-H.; Kočan, M. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul Lez Durance (France); Koslowski, H.R. [Forschungszentrum Jülich GmbH, Institute of Energy and Climate Research—Plasma Physics, Association EURATOM-FZJ, Trilateral Euregio Cluster, 52425 Jülich (Germany); Kovalenko, D. [SRC RF TRINITI, ul. Pushkovykh, vladenie 12, Troitsk, Moscow 142190 (Russian Federation); Kruezi, U. [CCFE, Culham Science Centre, Abingdon, Oxon, OX14 3DB (United Kingdom); and others

    2015-08-15

    The thermal and electromagnetic loads related to disruptions in ITER are substantial and require careful design of tokamak components to ensure they reach the projected lifetime and to ensure that safety relevant components fulfil their function for the worst foreseen scenarios. The disruption load specifications are the basis for the design process of components like the full-W divertor, the blanket modules and the vacuum vessel and will set the boundary conditions for ITER operations. This paper will give a brief overview on the disruption loads and mitigation strategies for ITER and will discuss the physics basis which is continuously refined through the current disruption R&D programs.

  13. Adaptive control in series load PWM induction heating inverters

    Science.gov (United States)

    Szelitzky, Tibor; Henrietta Dulf, Eva

    2013-12-01

    Permanent variations of the electric properties of the load in induction heating equipment make difficult to control the plant. To overcome these disadvantages, the authors propose a new approach based on adaptive control methods. For real plants it is enough to present desired performances or start-up variables for the controller, from which the algorithms tune the controllers by itself. To present the advantages of the proposed controllers, comparisons are made to a PI controller tuned through Ziegler-Nichols method.

  14. Control Strategy Tool (CoST)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The EPA Control Strategy Tool (CoST) is a software tool for projecting potential future control scenarios, their effects on emissions and estimated costs. This tool...

  15. 40 CFR 52.1982 - Control strategy: Ozone.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Ozone. 52.1982... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Oregon § 52.1982 Control strategy... emission control equipment, selected from a specific list on file at DEQ, is in place and operating...

  16. Occupant satisfaction with two blind control strategies

    DEFF Research Database (Denmark)

    Karlsen, Line Røseth; Heiselberg, Per Kvols; Bryn, Ida

    2015-01-01

    Highlights •Occupant satisfaction with two blind control strategies has been studied. •Control based on cut-off position of slats was more popular than closed slats. •Results from the study are helpful in development of control strategies for blinds. •The results give indications of how blinds...

  17. A Study of Distributed Generation System Characteristics and Protective Load Control Strategy

    DEFF Research Database (Denmark)

    Wei, Mu; Chen, Zhe

    2011-01-01

    Due to the smaller inertia feature of a Wind Turbine (WT) involved Distributed Generation System (DGS), the WT’s induction generator are more vulnerable to frequency and voltage disturbances. Therefore the study investigates the DGS characteristics respectively from power plants, i.e. WTs and load....... Two kinds of wind turbines: Doubly-fed Induction Generator (DFIG) and Fixed-speed Wind Turbine (FSWT) are compared in this study. A conventional power system protective scheme may not response promptly, which could lead an undesired disconnection of WTs for the turbine protection purpose. Consequently...

  18. Load frequency control of an asynchronous restructured power system

    African Journals Online (AJOL)

    This paper presents the analysis of load frequency control (LFC) of a two-area restructured power system interconnected via parallel ac/dc transmission links. Simulation results show that the limitations of PI controller can be overcome by including Fuzzy logic concept and thereby the dynamic performance can be improved ...

  19. H-M bearing capacity of a modified suction caisson determined by using load-/displacement-controlled methods

    Science.gov (United States)

    Zhang, Yu-kun; Gao, Yu-feng; Li, Da-yong; Mahfouz, Ali H.

    2016-12-01

    This paper presents a series of monotonically combined lateral loading tests to investigate the bearing capacity of the MSCs (modified suction caissons) in the saturated marine fine sand. The lateral loads were applied under load- and displacement-controlled methods at the loading eccentricity ratios of 1.5, 2.0 and 2.5. Results show that, in the displacement-controlled test, the deflection-softening behavior of load-deflection curves for MSCs was observed, and the softening degree of the load-deflection response increased with the increasing external skirt length or the decreasing loading eccentricity. It was also found that the rotation center of the MSC at failure determined by the load-controlled method is slightly lower than that by the displacement-controlled method. The calculated MSC capacity based on the rotation center position in serviceability limit state is relatively conservative, compared with the calculated capacity based on the rotation center position in the ultimate limit state. In the limit state, the passive earth pressures opposite the loading direction under load- and displacement-controlled methods decrease by 46% and 74% corresponding to peak values, respectively; however, the passive earth pressures in the loading direction at failure only decrease by approximately 3% and 7%, compared with their peak values.

  20. Effects of intermediate load on performance limitations in excitation control

    Directory of Open Access Journals (Sweden)

    Pichai Aree

    2008-05-01

    Full Text Available The stability of excitation control systems is of great concern in power system operations. In this paper, the effects of intermediate load on performance limitation in excitation control are studied. The results reveal that the open-loop characteristic of synchronous machine’s flux linkage can be changed from minimum to non-minimum phase at a high level of intermediate load. This change leads to instability of synchronous machines under manual excitation control. A particular emphasis is also given to investigate the fundamental limitations in excitation control, imposed by non-minimum phases with regard to the open-loop right-half-plane (ORHP pole. The study demonstrates the difficulties of excitation control tuning to achieve the desired performance and robustness under the ORHP pole occurrence. Moreover, this paper shows the conditional stability in excitation control loop, where either an increase or decrease of the exciter gain causes a destabilization of the system’s stability. Frequency response techniques are used for these investigations.

  1. Parameter Improved Particle Swarm Optimization Based Direct-Current Vector Control Strategy for Solar PV System

    Directory of Open Access Journals (Sweden)

    NAMMALVAR, P.

    2018-02-01

    Full Text Available This paper projects Parameter Improved Particle Swarm Optimization (PIPSO based direct current vector control technology for the integration of photovoltaic array in an AC micro-grid to enhance the system performance and stability. A photovoltaic system incorporated with AC micro-grid is taken as the pursuit of research study. The test system features two power converters namely, PV side converter which consists of DC-DC boost converter with Perturbation and Observe (P&O MPPT control to reap most extreme power from the PV array, and grid side converter which consists of Grid Side-Voltage Source Converter (GS-VSC with proposed direct current vector control strategy. The gain of the proposed controller is chosen from a set of three values obtained using apriori test and tuned through the PIPSO algorithm so that the Integral of Time multiplied Absolute Error (ITAE between the actual and the desired DC link capacitor voltage reaches a minimum and allows the system to extract maximum power from PV system, whereas the existing d-q control strategy is found to perform slowly to control the DC link voltage under varying solar insolation and load fluctuations. From simulation results, it is evident that the proposed optimal control technique provides robust control and improved efficiency.

  2. New regenerative braking control strategy for rear-driven electrified minivans

    International Nuclear Information System (INIS)

    Junzhi, Zhang; Yutong, Li; Chen, Lv; Ye, Yuan

    2014-01-01

    Highlights: • A regenerative braking system is designed for a rear-driven electric minivan. • A new control strategy coordinating energy efficiency and braking feel is proposed. • The control strategy is verified by simulation and hardware-in-loop (HIL) tests. • The proposed control strategy offers higher regeneration efficiency. - Abstract: As of to 2012, minivan ownership stood at 20 million units in China, accounting for 16% of the passenger car market. In this article, comprehensive research is carried out on the design and control of a regenerative braking system for a rear-driven electrified minivan. For improving the regeneration efficiency by as much as possible, a new regenerative braking control strategy called “modified control strategy” is proposed. Additionally, a control strategy called “baseline control strategy” is introduced as a comparative control strategy. Simulations and hardware-in-loop (HIL) tests are carried out. The results of the simulations and the HIL tests show that the modified control strategy offers considerably higher regeneration efficiency than the baseline control strategy. In normal deceleration braking, the regeneration efficiency of the modified control strategy reaches 47%, 15% higher than that of the baseline control strategy. In addition, improvement in the fuel economy of electric vehicles operating on the ECE driving cycle and enhanced with the modified control strategy is greater than 10%, which is 3% higher than that with the baseline control strategy

  3. Application of two passive strategies on the load mitigation of large offshore wind turbines

    Science.gov (United States)

    Shirzadeh, Rasoul; Kühn, Martin

    2016-09-01

    This study presents the numerical results of two passive strategies to reduce the support structure loads of a large offshore wind turbine. In the first approach, an omnidirectional tuned mass damper is designed and implemented in the tower top to alleviate the structural vibrations. In the second approach, a viscous fluid damper model which is diagonally attached to the tower at two points is developed. Aeroelastic simulations are performed for the offshore 10MW INNWIND.EU reference wind turbine mounted on a jacket structure. Lifetime damage equivalent loads are evaluated at the tower base and compared with those for the reference wind turbine. The results show that the integrated design can extend the lifetime of the support structure.

  4. Optimized Control Strategy for a Medium-Voltage DVR-Theoretical Investigations and Experimental Results

    DEFF Research Database (Denmark)

    Meyer, Christoph; De Doncker, Rik W.; Li, Yun Wei

    2008-01-01

    Most power quality problems in distribution systems are related to voltage sags. Therefore, different solutions have been examined to compensate these sags to avoid production losses at sensitive loads. Dynamic voltage restorers (DVRs) have been proposed to provide higher power quality. Currently......, a system wide integration of DVRs is hampered because of their high cost, in particular, due to the expensive DC-link energy storage devices. The cost of these DC-link capacitors remains high because the DVR requires a minimum DC-link voltage to be able to operate and to compensate a sag. As a result, only...... a small fraction of the energy stored in the DC-link capacitor is used, which makes it impractical for DVRs to compensate relatively long voltage sags. Present control strategies are only able to minimize the distortions at the load or to allow a better utilization of the storage system by minimizing...

  5. INCA Modelling of the Lee System: strategies for the reduction of nitrogen loads

    Science.gov (United States)

    Flynn, N. J.; Paddison, T.; Whitehead, P. G.

    The Integrated Nitrogen Catchment model (INCA) was applied successfully to simulate nitrogen concentrations in the River Lee, a northern tributary of the River Thames for 1995-1999. Leaching from urban and agricultural areas was found to control nitrogen dynamics in reaches unaffected by effluent discharges and abstractions; the occurrence of minimal flows resulted in an upward trend in nitrate concentration. Sewage treatment works (STW) discharging into the River Lee raised nitrate concentrations substantially, a problem which was compounded by abstractions in the Lower Lee. The average concentration of nitrate (NO3) for the simulation period 1995-96 was 7.87 mg N l-1. Ammonium (NH4) concentrations were simulated less successfully. However, concentrations of ammonium rarely rose to levels which would be of environmental concern. Scenarios were run through INCA to assess strategies for the reduction of nitrate concentrations in the catchment. The conversion of arable land to ungrazed vegetation or to woodland would reduce nitrate concentrations substantially, whilst inclusion of riparian buffer strips would be unsuccessful in reducing nitrate loading. A 50% reduction in nitrate loading from Luton STW would result in a fall of up to 5 mg N l-1 in the reach directly affected (concentrations fell from maxima of 13 to 8 mg N l-1 , nearly a 40 % reduction), whilst a 20% reduction in abstractions would reduce maximum peaks in concentration in the lower Lee by up to 4 mg l-1 (from 17 to 13 mg N l-1, nearly a 25 % reduction),.

  6. Design of the Driving and Clamp Rotation Hydraulic Control System for the Heavy Load Forging Manipulator

    Directory of Open Access Journals (Sweden)

    Li Geqiang

    2015-01-01

    Full Text Available The manipulator was equipped with full hydraulic drive. We designed the hydraulic systems for the driving and clamping rotation. We used a fuzzy PID control strategy to design the electro-hydraulic proportional control system. We built a united simulation model based on the co-simulation of MATLAB/Simulink and AMEsim. A mathematical model of the system was also established. We did separate simulations of the system’s dynamic characteristics for fast forging and normal forging working conditions. The parameters were optimized. The field test shows that the steady-state error of the hydraulic system is small and the system response is fast. The system’s rapid response speed, high precision, and stability under heavy load were realized.

  7. A GPS-Based Control Method for Load Sharing and Power Quality Improvement in Microgrids

    DEFF Research Database (Denmark)

    Golsorkhi, Mohammad; Lu, Dylan; Savaghebi, Mehdi

    2016-01-01

    This paper proposes a novel control method for accurate sharing of load current among the Distributed Energy Resources (DER) and high power quality operating in islanded ac microgrids. This control scheme is based on hierarchical structure comprising of decentralized primary controllers and a cen....... The secondary controller produces compensation signals at fundamental and dominant harmonics to improve the voltage quality at a sensitive load bus. Experimental results are presented to validate the efficacy of the proposed method.......This paper proposes a novel control method for accurate sharing of load current among the Distributed Energy Resources (DER) and high power quality operating in islanded ac microgrids. This control scheme is based on hierarchical structure comprising of decentralized primary controllers...

  8. Maintenance of equilibrium point control during an unexpectedly loaded rapid limb movement.

    Science.gov (United States)

    Simmons, R W; Richardson, C

    1984-06-08

    Two experiments investigated whether the equilibrium point hypothesis or the mass-spring model of motor control subserves positioning accuracy during spring loaded, rapid, bi-articulated movement. For intact preparations, the equilibrium point hypothesis predicts response accuracy to be determined by a mixture of afferent and efferent information, whereas the mass-spring model predicts positioning to be under a direct control system. Subjects completed a series of load-resisted training trials to a spatial target. The magnitude of a sustained spring load was unexpectedly increased on selected trials. Results indicated positioning accuracy and applied force varied with increases in load, which suggests that the original efferent commands are modified by afferent information during the movement as predicted by the equilibrium point hypothesis.

  9. Multi-Stage Admission Control for Load Balancing in Next Generation Systems

    DEFF Research Database (Denmark)

    Mihovska, Albena D.; Anggorojati, Bayu; Luo, Jijun

    2008-01-01

    This paper describes a load-dependent multi-stage admission control suitable for next generation systems. The concept uses decision polling in entities located at different levels of the architecture hierarchy and based on the load to activate a sequence of actions related to the admission...

  10. Optimal control of load-following operations in a pressurized water reactor

    International Nuclear Information System (INIS)

    Zhao Fuyu; Zhou Dawei

    2000-01-01

    According to the optimal control theory, the problem of load-following operation in a pressurized water reactor is formulated as a nonlinear-quadratic optimal control problem. One-dimensional core model is adopted. A successful optimization algorithm DDPSR is proposed to solving the obtained problem. The research results show that the DDPSR can converge with a long time interval and needs very small iteration number and computing time, and the practical reactor can be fairly operated in an optimal load-following manner and axial offset satisfies the required value from beginning to end. Control characters of boron concentration are discussed specially

  11. Optimal fuzzy logic-based PID controller for load-frequency control including superconducting magnetic energy storage units

    International Nuclear Information System (INIS)

    Pothiya, Saravuth; Ngamroo, Issarachai

    2008-01-01

    This paper proposes a new optimal fuzzy logic-based-proportional-integral-derivative (FLPID) controller for load frequency control (LFC) including superconducting magnetic energy storage (SMES) units. Conventionally, the membership functions and control rules of fuzzy logic control are obtained by trial and error method or experiences of designers. To overcome this problem, the multiple tabu search (MTS) algorithm is applied to simultaneously tune PID gains, membership functions and control rules of FLPID controller to minimize frequency deviations of the system against load disturbances. The MTS algorithm introduces additional techniques for improvement of search process such as initialization, adaptive search, multiple searches, crossover and restarting process. Simulation results explicitly show that the performance of the optimum FLPID controller is superior to the conventional PID controller and the non-optimum FLPID controller in terms of the overshoot, settling time and robustness against variations of system parameters

  12. Sleeper Cab Climate Control Load Reduction for Long-Haul Truck Rest Period Idling

    Energy Technology Data Exchange (ETDEWEB)

    Lustbader, J. A.; Kreutzer, C.; Adelman, S.; Yeakel, S.; Zehme, J.

    2015-04-29

    Annual fuel use for long-haul truck rest period idling is estimated at 667 million gallons in the United States. The U.S. Department of Energy’s National Renewable Energy Laboratory’s CoolCab project aims to reduce heating, ventilating, and air conditioning (HVAC) loads and resulting fuel use from rest period idling by working closely with industry to design efficient long-haul truck climate control systems while maintaining occupant comfort. Enhancing the thermal performance of cab/sleepers will enable smaller, lighter, and more cost-effective idle reduction solutions. In order for candidate idle reduction technologies to be implemented at the original equipment manufacturer and fleet level, their effectiveness must be quantified. To address this need, a number of promising candidate technologies were evaluated through experimentation and modeling to determine their effectiveness in reducing rest period HVAC loads. For this study, load reduction strategies were grouped into the focus areas of solar envelope, occupant environment, and conductive pathways. The technologies selected for a complete-cab package of technologies were “ultra-white” paint, advanced insulation, and advanced curtains. To measure the impact of these technologies, a nationally-averaged solar-weighted reflectivity long-haul truck paint color was determined and applied to the baseline test vehicle. Using the complete-cab package of technologies, electrical energy consumption for long-haul truck daytime rest period air conditioning was reduced by at least 35% for summer weather conditions in Colorado. The National Renewable Energy Laboratory's CoolCalc model was then used to extrapolate the performance of the thermal load reduction technologies nationally for 161 major U.S. cities using typical weather conditions for each location over an entire year.

  13. Optimal fault-tolerant control strategy of a solid oxide fuel cell system

    Science.gov (United States)

    Wu, Xiaojuan; Gao, Danhui

    2017-10-01

    For solid oxide fuel cell (SOFC) development, load tracking, heat management, air excess ratio constraint, high efficiency, low cost and fault diagnosis are six key issues. However, no literature studies the control techniques combining optimization and fault diagnosis for the SOFC system. An optimal fault-tolerant control strategy is presented in this paper, which involves four parts: a fault diagnosis module, a switching module, two backup optimizers and a controller loop. The fault diagnosis part is presented to identify the SOFC current fault type, and the switching module is used to select the appropriate backup optimizer based on the diagnosis result. NSGA-II and TOPSIS are employed to design the two backup optimizers under normal and air compressor fault states. PID algorithm is proposed to design the control loop, which includes a power tracking controller, an anode inlet temperature controller, a cathode inlet temperature controller and an air excess ratio controller. The simulation results show the proposed optimal fault-tolerant control method can track the power, temperature and air excess ratio at the desired values, simultaneously achieving the maximum efficiency and the minimum unit cost in the case of SOFC normal and even in the air compressor fault.

  14. Sensorless load torque estimation and passivity based control of buck converter fed DC motor.

    Science.gov (United States)

    Kumar, S Ganesh; Thilagar, S Hosimin

    2015-01-01

    Passivity based control of DC motor in sensorless configuration is proposed in this paper. Exact tracking error dynamics passive output feedback control is used for stabilizing the speed of Buck converter fed DC motor under various load torques such as constant type, fan type, propeller type, and unknown load torques. Under load conditions, sensorless online algebraic approach is proposed, and it is compared with sensorless reduced order observer approach. The former produces better response in estimating the load torque. Sensitivity analysis is also performed to select the appropriate control variables. Simulation and experimental results fully confirm the superiority of the proposed approach suggested in this paper.

  15. Dynamic Strategies for Yaw and Induction Control of Wind Farms Based on Large-Eddy Simulation and Optimization

    Directory of Open Access Journals (Sweden)

    Wim Munters

    2018-01-01

    Full Text Available In wind farms, wakes originating from upstream turbines cause reduced energy extraction and increased loading variability in downstream rows. The prospect of mitigating these detrimental effects through coordinated controllers at the wind-farm level has fueled a multitude of research efforts in wind-farm control. The main strategies in wind-farm control are to influence the velocity deficits in the wake by deviating from locally optimal axial induction setpoints on the one hand, and steering wakes away from downstream rows through yaw misalignment on the other hand. The current work investigates dynamic induction and yaw control of individual turbines for wind-farm power maximization in large-eddy simulations. To this end, receding-horizon optimal control techniques combined with continuous adjoint gradient evaluations are used. We study a 4 × 4 aligned wind farm, and find that for this farm layout yaw control is more effective than induction control, both for uniform and turbulent inflow conditions. Analysis of optimal yaw controls leads to the definition of two simplified yaw control strategies, in which wake meandering and wake redirection are exploited respectively. Furthermore it is found that dynamic yawing provides significant benefits over static yaw control in turbulent flow environments, whereas this is not the case for uniform inflow. Finally, the potential of combining overinductive axial induction control with yaw control is shown, with power gains that approximate the sum of those achieved by each control strategy separately.

  16. Rod behaviour under base load, load follow and frequency control operation: CYRANO 2 code predictions versus experimental results

    International Nuclear Information System (INIS)

    Gautier, B.; Raybaud, A.

    1984-01-01

    The French PWR reactors are now currently operating under load follow and frequency control. In order to demonstrate that these operating conditions were not able to increase the fuel failure rate, fuel rod behaviour calculations have been performed by E.D.F. with CYRANO 2 code. In parallel with these theoretical calculations, code predictions have been compared to experimental results. The paper presents some of the comparisons performed on 17x17 fuel irradiated in FESSENHEIM 2 up to 30 GWd/tU under base load operation and in the CAP reactor under load follow and frequency control conditions. It is shown that experimental results can be predicted with a reasonable accuracy by CYRANO 2 code. The experimental work was carried out under joint R and D programs by EDF, FRAGEMA, CEA, and WESTINGHOUSE (CAP program by French partners only). (author)

  17. The effects of rhythm control strategies versus rate control strategies for atrial fibrillation and atrial flutter

    DEFF Research Database (Denmark)

    Sethi, Naqash; Safi, Sanam; Nielsen, Emil E

    2017-01-01

    by Jakobsen and colleagues. We plan to include all relevant randomised clinical trials assessing the effects of any rhythm control strategy versus any rate control strategy. We plan to search the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, EMBASE, LILACS, Science Citation Index Expanded...... on Web of Science, and BIOSIS to identify relevant trials. Any eligible trial will be assessed and classified as either high risk of bias or low risk of bias, and our conclusions will be based on trials with low risk of bias. The analyses of the extracted data will be performed using Review Manager 5....... This protocol for a systematic review aims at identifying the best overall treatment strategy for atrial fibrillation and atrial flutter. METHODS: This protocol for a systematic review was performed following the recommendations of the Cochrane Collaboration and the eight-step assessment procedure suggested...

  18. Real-Time Adaptive Control of a Magnetic Levitation System with a Large Range of Load Disturbance.

    Science.gov (United States)

    Zhang, Zhizhou; Li, Xiaolong

    2018-05-11

    In an idle light-load or a full-load condition, the change of the load mass of a suspension system is very significant. If the control parameters of conventional control methods remain unchanged, the suspension performance of the control system deteriorates rapidly or even loses stability when the load mass changes in a large range. In this paper, a real-time adaptive control method for a magnetic levitation system with large range of mass changes is proposed. First, the suspension control system model of the maglev train is built up, and the stability of the closed-loop system is analyzed. Then, a fast inner current-loop is used to simplify the design of the suspension control system, and an adaptive control method is put forward to ensure that the system is still in a stable state when the load mass varies in a wide range. Simulations and experiments show that when the load mass of the maglev system varies greatly, the adaptive control method is effective to suspend the system stably with a given displacement.

  19. Impact loading of a BWR control rod during braking

    International Nuclear Information System (INIS)

    Heeschen, U.

    1977-01-01

    In an emergency case the control rods of a boiling water reactor are shot into the RPV from below against the weight of the rods with drive motors. According to the position of the control rods between the fuel elements the rods can reach in that case velocities up to 4 m/s. The moved masses of the control rods and of the pistons (both of them are connected by a coupling) are braked through a cup spring which transfers its forces to the RPV-bottom sphere. The spring has to be designed that in this case tthe complete kinetic energy of he control rods of about 1000Nm can be taken up. The spring power and the inertia of the moved masses cause extremely high loadings during and shortly after the impact onto the spring. The shock-like loading propagates along the whole rod at the speed of sound, and this is also the reason why the weaker cross-sections have to endure considerable short-term stress peaks. (Auth.)

  20. Tuningless Load Frequency Control Through Active Engagement of Distributed Resources

    DEFF Research Database (Denmark)

    Prostejovsky, Alexander; Marinelli, Mattia; Rezkalla, Michel M.N.

    2017-01-01

    system dynamics. Second, primary resources are actively involved in frequency restoration by systematic adjustment of their frequency reference setpoints. In contrast to the commonly used Automatic Generation Control (AGC), the proposed Direct Load Frequency Control (DLFC) does not require an integrator...

  1. Research on charging and discharging control strategy for electric vehicles as distributed energy storage devices

    Science.gov (United States)

    Zhang, Min; Yang, Feng; Zhang, Dongqing; Tang, Pengcheng

    2018-02-01

    A large number of electric vehicles are connected to the family micro grid will affect the operation safety of the power grid and the quality of power. Considering the factors of family micro grid price and electric vehicle as a distributed energy storage device, a two stage optimization model is established, and the improved discrete binary particle swarm optimization algorithm is used to optimize the parameters in the model. The proposed control strategy of electric vehicle charging and discharging is of practical significance for the rational control of electric vehicle as a distributed energy storage device and electric vehicle participating in the peak load regulation of power consumption.

  2. A New Control Method for a Bi-Directional Phase-Shift-Controlled DC-DC Converter with an Extended Load Range

    Directory of Open Access Journals (Sweden)

    Wenzheng Xu

    2017-10-01

    Full Text Available Phase-shifted converters are practically important to provide high conversion efficiencies through soft-switching techniques. However, the limitation on a resonant inductor current in the converters often leads to a non-fulfillment of the requirement of minimum load current. This paper presents a new power electronics control technique to enable the dual features of bi-directional power flow and an extended load range for soft-switching in phase-shift-controlled DC-DC converters. The proposed technique utilizes two identical full bridge converters and inverters in conjunction with a new control logic for gate-driving signals to facilitate both Zero Current Switching (ZCS and Zero Voltage Switching (ZVS in a single phase-shift-controlled DC-DC converter. The additional ZCS is designed for light load conditions at which the minimum load current cannot be attained. The bi-directional phase-shift-controlled DC-DC converter can implement the function of synchronous rectification. Its fast dynamic response allows for quick energy recovery during the regenerative braking of traction systems in electrified trains.

  3. Controlled Bioactive Molecules Delivery Strategies for Tendon and Ligament Tissue Engineering using Polymeric Nanofibers.

    Science.gov (United States)

    Hiong Teh, Thomas Kok; Hong Goh, James Cho; Toh, Siew Lok

    2015-01-01

    The interest in polymeric nanofibers has escalated over the past decade given its promise as tissue engineering scaffolds that can mimic the nanoscale structure of the native extracellular matrix. With functionalization of the polymeric nanofibers using bioactive molecules, localized signaling moieties can be established for the attached cells, to stimulate desired biological effects and direct cellular or tissue response. The inherently high surface area per unit mass of polymeric nanofibers can enhance cell adhesion, bioactive molecules loading and release efficiencies, and mass transfer properties. In this review article, the application of polymeric nanofibers for controlled bioactive molecules delivery will be discussed, with a focus on tendon and ligament tissue engineering. Various polymeric materials of different mechanical and degradation properties will be presented along with the nanofiber fabrication techniques explored. The bioactive molecules of interest for tendon and ligament tissue engineering, including growth factors and small molecules, will also be reviewed and compared in terms of their nanofiber incorporation strategies and release profiles. This article will also highlight and compare various innovative strategies to control the release of bioactive molecules spatiotemporally and explore an emerging tissue engineering strategy involving controlled multiple bioactive molecules sequential release. Finally, the review article concludes with challenges and future trends in the innovation and development of bioactive molecules delivery using polymeric nanofibers for tendon and ligament tissue engineering.

  4. 40 CFR 52.2332 - Control Strategy: Ozone.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control Strategy: Ozone. 52.2332 Section 52.2332 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Utah § 52.2332 Control Strategy...

  5. 40 CFR 52.1885 - Control strategy: Ozone.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Ozone. 52.1885 Section 52.1885 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Ohio § 52.1885 Control strategy...

  6. 40 CFR 52.1023 - Control strategy: Ozone.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Ozone. 52.1023 Section 52.1023 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Maine § 52.1023 Control strategy...

  7. Participation of Flexible Loads in Load Frequency Control to Support High Wind Penetration

    DEFF Research Database (Denmark)

    Uslu, Umur; Zhang, Boyang; Pillai, Jayakrishnan Radhakrishna

    2016-01-01

    The increasing amount of fluctuating wind power penetration in power systems presents many challenges to its operation and control. The new wind power plants are replacing many of the conventional large power plants that ensure power balancing and ancillary services for stable and reliable...... operation of the grid. Therefore, new solutions for power balancing reserves have to be explored and utilized by the grid utilities. To meet these challenges, large sizable loads like alkaline electrolysers, heat pumps and electric vehicles which are gaining popularity can provide system support to the grid...... through their inherent flexibility and energy storage characteristics. This paper investigates the possibilities and potential of such flexible loads to participate in power system frequency regulation in a wind dominated power system. The results show that these consumption units provide better...

  8. A Bi-Level Optimization Approach to Charging Load Regulation of Electric Vehicle Fast Charging Stations Based on a Battery Energy Storage System

    Directory of Open Access Journals (Sweden)

    Yan Bao

    2018-01-01

    Full Text Available Fast charging stations enable the high-powered rapid recharging of electric vehicles. However, these stations also face challenges due to power fluctuations, high peak loads, and low load factors, affecting the reliable and economic operation of charging stations and distribution networks. This paper introduces a battery energy storage system (BESS for charging load control, which is a more user-friendly approach and is more robust to perturbations. With the goals of peak-shaving, total electricity cost reduction, and minimization of variation in the state-of-charge (SOC range, a BESS-based bi-level optimization strategy for the charging load regulation of fast charging stations is proposed in this paper. At the first level, a day-ahead optimization strategy generates the optimal planned load curve and the deviation band to be used as a reference for ensuring multiple control objectives through linear programming, and even for avoiding control failure caused by insufficient BESS energy. Based on this day-ahead optimal plan, at a second level, real-time rolling optimization converts the control process to a multistage decision-making problem. The predictive control-based real-time rolling optimization strategy in the proposed model was used to achieve the above control objectives and maintain battery life. Finally, through a horizontal comparison of two control approaches in each case study, and a longitudinal comparison of the control robustness against different degrees of load disturbances in three cases, the results indicated that the proposed control strategy was able to significantly improve the charging load characteristics, even with large disturbances. Meanwhile, the proposed approach ensures the least amount of variation in the range of battery SOC and reduces the total electricity cost, which will be of a considerable benefit to station operators.

  9. Enhancement of Voltage Stability of DC Smart Grid During Islanded Mode by Load Shedding Scheme

    Science.gov (United States)

    Nassor, Thabit Salim; Senjyu, Tomonobu; Yona, Atsushi

    2015-10-01

    This paper presents the voltage stability of a DC smart grid based on renewable energy resources during grid connected and isolated modes. During the islanded mode the load shedding, based on the state of charge of the battery and distribution line voltage, was proposed for voltage stability and reservation of critical load power. The analyzed power system comprises a wind turbine, a photovoltaic generator, storage battery as controllable load, DC loads, and power converters. A fuzzy logic control strategy was applied for power consumption control of controllable loads and the grid-connected dual active bridge series resonant converters. The proposed DC Smart Grid operation has been verified by simulation using MATLAB® and PLECS® Blockset. The obtained results show the effectiveness of the proposed method.

  10. Optimal control strategy design for extending all-electric driving capability of plug-in hybrid electric vehicles (PHEVs)

    Energy Technology Data Exchange (ETDEWEB)

    Williamson, S.S [Concordia Univ., Montreal, PQ (Canada). Dept. of Electrical and Computer Engineering, P.D Ziogas Power Electronics Laboratory

    2007-07-01

    The high voltage energy storage system in plug-in hybrid electric vehicles (PHEVs) is usually a rechargeable type that service a dual purpose, notably to supplement the power delivered by the internal combustion engine, and to provide partial propulsion energy from an off-board source of electricity. The energy storage devices in electric vehicles typically improve vehicle efficiency through engine downsizing and by recapturing braking energy. However, since PHEVs have the ability to recharge their energy storage systems directly from the power grid, the periods of all-electric operation can be extended, thereby reducing the dependence on the internal combustion engine. This is particularly useful in city driving conditions. Developers of PHEV technology are faced with the challenge of choosing the appropriate energy storage battery in order to improve the all-electric drive range. In this study, control strategies were modeled for specific driving load conditions using the Advanced Vehicle Simulator (ADVISOR) software. This paper presented specific control algorithms for PHEV operation for various city driving loads. The optimal design strategy considered the improvement of critical energy storage parameters, overall drive train efficiency, and vehicle performance characteristics. Future trends in the design and development of PHEV drive trains were also presented. 13 figs.

  11. 40 CFR 52.377 - Control strategy: Ozone.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control strategy: Ozone. 52.377 Section 52.377 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Connecticut § 52.377 Control strategy: Ozone. (a...

  12. 40 CFR 52.66 - Control Strategy: Ozone.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control Strategy: Ozone. 52.66 Section 52.66 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Alabama § 52.66 Control Strategy: Ozone. (a) The...

  13. 40 CFR 52.582 - Control strategy: Ozone.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control strategy: Ozone. 52.582 Section 52.582 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Georgia> § 52.582 Control strategy: Ozone. (a) Approval...

  14. 40 CFR 52.350 - Control strategy: Ozone.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control strategy: Ozone. 52.350 Section 52.350 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Colorado § 52.350 Control strategy: Ozone. (a) Revisions...

  15. Ground reaction force comparison of controlled resistance methods to isoinertial loading of the squat exercise - biomed 2010.

    Science.gov (United States)

    Paulus, David C; Reynolds, Michael C; Schilling, Brian K

    2010-01-01

    The ground reaction force during the concentric (raising) portion of the squat exercise was compared to that of isoinertial loading (free weights) for three pneumatically controlled resistance methods: constant resistance, cam force profile, and proportional force control based on velocity. Constant force control showed lower ground reaction forces than isoinertial loading throughout the range of motion (ROM). The cam force profile exhibited slightly greater ground reaction forces than isoinertial loading at 10 and 40% ROM with fifty-percent greater loading at 70% ROM. The proportional force control consistently elicited greater ground reaction force than isoinertial loading, which progressively ranged from twenty to forty percent increase over isoinertial loading except for being approximately equal at 85% ROM. Based on these preliminary results, the proportional control shows the most promise for providing loading that is comparable in magnitude to isoinertial loading. This technology could optimize resistance exercise for sport-specific training or as a countermeasure to atrophy during spaceflight.

  16. National Drug Control Strategy. Update.

    Science.gov (United States)

    Office of National Drug Control Policy, Washington, DC.

    President Bush's new National Drug Control Strategy for 2003 focuses on three core priorities: stopping drug use before it starts; healing America's drug users; and disrupting the market. The 2003 strategy reports progress toward meeting the President's goals of reducing drug use by 10 percent over 2 years, and 25 percent over 5 years. With regard…

  17. New strategies of reloads design and models of control bars in boiling water reactors; Nuevas estrategias de diseno de recargas y de patrones de barras de control en reactores de agua en ebullicion

    Energy Technology Data Exchange (ETDEWEB)

    Castillo M, J. A.; Ortiz S, J. J.; Perusquia del Cueto, R., E-mail: alejandro.castillo@inin.gob.mx [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2011-11-15

    In this work the results obtained when analyzing new strategies in the reload designs of nuclear fuel and models of control bars, for boiling water reactors are presented. The idea is to analyze the behaviour of the reactor during an operation cycle, when the heuristic rules are not used (commonly used by expert engineers in both designs). Specifically was analyzed the rule of low leak and the load strategy Control Cell Core for the design of a fuel reload. In a same way was analyzed the rule of prohibiting the use of the intermediate positions in the control bars, as well as the construction of bar models based on load strategies type Control Cell Core. In the first analysis a balance and transition cycle were used. For the second analysis only a transition cycle was used, firstly with the reloads designed in the first analysis and later on with reloads built by other methods. For the simulation of the different configurations proposed in both cases, was used the code Simulate-3. To obtain the designs in both studies, the heuristic techniques or neural networks and taboo search were used. The obtained results show that it can be omitted of some rules used in the ambit for the mentioned designs and even so to obtain good results. To carry out this investigation was used Dell work station under Li nux platform. (Author)

  18. Tuning of PID load frequency controller for power systems

    International Nuclear Information System (INIS)

    Tan Wen

    2009-01-01

    PID tuning of load frequency controllers for power systems is discussed in this paper. The tuning method is based on a two-degree-of-freedom internal model control (IMC) design method, and the performance of the resulting PID controller is related to two tuning parameters thus detuning is easy when necessary. Then an anti-GRC scheme is proposed to overcome the generation rate constraints. Finally, the method is extended to two-area cases.

  19. Implementation of internal model based control and individual pitch control to reduce fatigue loads and tower vibrations in wind turbines

    Science.gov (United States)

    Mohammadi, Ebrahim; Fadaeinedjad, Roohollah; Moschopoulos, Gerry

    2018-05-01

    Vibration control and fatigue loads reduction are important issues in large-scale wind turbines. Identifying the vibration frequencies and tuning dampers and controllers at these frequencies are major concerns in many control methods. In this paper, an internal model control (IMC) method with an adaptive algorithm is implemented to first identify the vibration frequency of the wind turbine tower and then to cancel the vibration signal. Standard individual pitch control (IPC) is also implemented to compare the performance of the controllers in term of fatigue loads reduction. Finally, the performance of the system when both controllers are implemented together is evaluated. Simulation results demonstrate that using only IMC or IPC alone has advantages and can reduce fatigue loads on specific components. IMC can identify and suppress tower vibrations in both fore-aft and side-to-side directions, whereas, IPC can reduce fatigue loads on blades, shaft and yaw bearings. When both IMC and IPC are implemented together, the advantages of both controllers can be used. The aforementioned analysis and comparisons were not studied in literature and this study fills this gap. FAST, AreoDyn and Simulink are used to simulate the mechanical, aerodynamic and electrical aspects of wind turbine.

  20. Impact of working memory load on cognitive control in trait anxiety: an ERP study.

    Science.gov (United States)

    Qi, Senqing; Zeng, Qinghong; Luo, Yangmei; Duan, Haijun; Ding, Cody; Hu, Weiping; Li, Hong

    2014-01-01

    Whether trait anxiety is associated with a general impairment of cognitive control is a matter of debate. This study investigated whether and how experimentally manipulated working memory (WM) load modulates the relation between trait anxiety and cognitive control. This question was investigated using a dual-task design in combination with event-related potentials. Participants were required to remember either one (low WM load) or six letters (high WM load) while performing a flanker task. Our results showed that a high WM load disrupted participants' ability to overcome distractor interference and this effect was exacerbated for the high trait-anxious (HTA) group. This exacerbation was reflected by larger interference effects (i.e., incongruent minus congruent) on reaction times (RTs) and N2 amplitudes for the HTA group than for the low trait-anxious group under high WM load. The two groups, however, did not differ in their ability to inhibit task-irrelevant distractors under low WM load, as indicated by both RTs and N2 amplitudes. These findings underscore the significance of WM-related cognitive demand in contributing to the presence (or absence) of a general cognitive control deficit in trait anxiety. Furthermore, our findings show that when limited WM resources are depleted by high WM load, HTA individuals exhibit less efficient recruitments of cognitive control required for the inhibition of distractors, therefore resulting in a greater degree of response conflict.

  1. Efficient community-based control strategies in adaptive networks

    International Nuclear Information System (INIS)

    Yang Hui; Tang Ming; Zhang Haifeng

    2012-01-01

    Most studies on adaptive networks concentrate on the properties of steady state, but neglect transient dynamics. In this study, we pay attention to the emergence of community structure in the transient process and the effects of community-based control strategies on epidemic spreading. First, by normalizing the modularity, we investigate the evolution of community structure during the transient process, and find that a strong community structure is induced by the rewiring mechanism in the early stage of epidemic dynamics, which, remarkably, delays the outbreak of disease. We then study the effects of control strategies started at different stages on the prevalence. Both immunization and quarantine strategies indicate that it is not ‘the earlier, the better’ for the implementation of control measures. And the optimal control effect is obtained if control measures can be efficiently implemented in the period of a strong community structure. For the immunization strategy, immunizing the susceptible nodes on susceptible–infected links and immunizing susceptible nodes randomly have similar control effects. However, for the quarantine strategy, quarantining the infected nodes on susceptible–infected links can yield a far better result than quarantining infected nodes randomly. More significantly, the community-based quarantine strategy performs better than the community-based immunization strategy. This study may shed new light on the forecast and the prevention of epidemics among humans. (paper)

  2. The effects of cognitive load on attention control in subclinical anxiety and Generalized Anxiety Disorder

    Science.gov (United States)

    Najmi, Sadia; Amir, Nader; Frosio, Kristen E.; Ayers, Catherine

    2014-01-01

    Poor regulation of emotions may involve impaired attention control. In the current paper, we report the results of two studies examining the interaction of anxiety, attention control, and cognitive load. In Study I, using a performance-based task to assess attention control, we examined whether anxiety is associated with impaired attention control, and whether these effects are influenced by working memory load. In Study II we examined these effects in patients with a diagnosis of Generalized Anxiety Disorder (GAD) compared to non-anxious control (NAC) participants. Results of Study I showed that high anxiety was associated with increased attention control, that is decreased interference from distractors, but only under high cognitive load. These results were replicated in Study II such that individuals with GAD showed increased attention control relative to NACs, but only under high cognitive load. These results help clarify previous predictions regarding the effect of anxiety on attention control. PMID:25355423

  3. Simple Models for Model-based Portfolio Load Balancing Controller Synthesis

    DEFF Research Database (Denmark)

    Edlund, Kristian Skjoldborg; Mølbak, Tommy; Bendtsen, Jan Dimon

    2010-01-01

    of generation units existing in an electrical power supply network, for instance in model-based predictive control or declarative control schemes. We focus on the effectuators found in the Danish power system. In particular, the paper presents models for boiler load, district heating, condensate throttling...

  4. A minimal order observer based frequency control strategy for an integrated wind-battery-diesel power system

    International Nuclear Information System (INIS)

    Howlader, Abdul Motin; Izumi, Yuya; Uehara, Akie; Urasaki, Naomitsu; Senjyu, Tomonobu; Yona, Atsushi; Saber, Ahmed Yousuf

    2012-01-01

    Wind energy is a fluctuating resource which can diverge quickly and causes the frequency deviation. To overcome this problem, the current paper deals with a frequency control scheme for a small power system by a coordinated control strategy of a wind turbine generator (WTG) and a battery energy storage system (BESS). The small power system composes of a wind turbine, a battery storage and a diesel generator. A minimal order observer is utilized as a disturbance observer to estimate the load of the power system. The load deviations are considered in a frequency domain. The low frequency component is reduced by the pitch angle control system of the WTG, while the high frequency component is reduced by the charge/discharge of the BESS, respectively. The output power command of the BESS is determined according to the state of charge, the high frequency component of the frequency deviation and the load variation. The proposed method is compared with the conventional method in different cases. By using the proposed method, the capacity of the battery is decreased by the charge/discharge of the BESS in long term. To enhance the control performance, the generalized predictive control (GPC) method is introduced to the pitch angle control system of the WTG. Effectiveness of the proposed method is verified by the numerical simulations. -- Highlights: ► A coordinated control method for a WTG and a BESS in the small power system. ► To achieve this objective, a minimal order observer is utilized. ► The output power command of the WTG is based on the wind speed and the estimated frequency deviations. ► The output power the WTG is controlled by the GPC based robust pitch angle control system. ► The output power command of the BESS is determined by the state of charge and the estimated frequency deviations.

  5. 40 CFR 52.2236 - Control strategy; lead.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy; lead. 52.2236 Section...) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Tennessee § 52.2236 Control strategy; lead... on October 6, 1994. These revisions address the requirements necessary to change a lead nonattainment...

  6. 40 CFR 52.930 - Control strategy: Ozone.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control strategy: Ozone. 52.930 Section 52.930 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Kentucky § 52.930 Control strategy: Ozone. (a) The VOC...

  7. 40 CFR 52.476 - Control strategy: ozone.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control strategy: ozone. 52.476 Section 52.476 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS District of Columbia § 52.476 Control strategy: ozone. (a...

  8. Decentralized model predictive based load frequency control in an interconnected power system

    Energy Technology Data Exchange (ETDEWEB)

    Mohamed, T.H., E-mail: tarekhie@yahoo.co [High Institute of Energy, South Valley University (Egypt); Bevrani, H., E-mail: bevrani@ieee.or [Dept. of Electrical Engineering and Computer Science, University of Kurdistan (Iran, Islamic Republic of); Hassan, A.A., E-mail: aahsn@yahoo.co [Faculty of Engineering, Dept. of Electrical Engineering, Minia University, Minia (Egypt); Hiyama, T., E-mail: hiyama@cs.kumamoto-u.ac.j [Dept. of Electrical Engineering and Computer Science, Kumamoto University, Kumamoto (Japan)

    2011-02-15

    This paper presents a new load frequency control (LFC) design using the model predictive control (MPC) technique in a multi-area power system. The MPC technique has been designed such that the effect of the uncertainty due to governor and turbine parameters variation and load disturbance is reduced. Each local area controller is designed independently such that stability of the overall closed-loop system is guaranteed. A frequency response model of multi-area power system is introduced, and physical constraints of the governors and turbines are considered. The model was employed in the MPC structures. Digital simulations for both two and three-area power systems are provided to validate the effectiveness of the proposed scheme. The results show that, with the proposed MPC technique, the overall closed-loop system performance demonstrated robustness in the face of uncertainties due to governors and turbines parameters variation and loads disturbances. A performance comparison between the proposed controller and a classical integral control scheme is carried out confirming the superiority of the proposed MPC technique.

  9. Decentralized model predictive based load frequency control in an interconnected power system

    International Nuclear Information System (INIS)

    Mohamed, T.H.; Bevrani, H.; Hassan, A.A.; Hiyama, T.

    2011-01-01

    This paper presents a new load frequency control (LFC) design using the model predictive control (MPC) technique in a multi-area power system. The MPC technique has been designed such that the effect of the uncertainty due to governor and turbine parameters variation and load disturbance is reduced. Each local area controller is designed independently such that stability of the overall closed-loop system is guaranteed. A frequency response model of multi-area power system is introduced, and physical constraints of the governors and turbines are considered. The model was employed in the MPC structures. Digital simulations for both two and three-area power systems are provided to validate the effectiveness of the proposed scheme. The results show that, with the proposed MPC technique, the overall closed-loop system performance demonstrated robustness in the face of uncertainties due to governors and turbines parameters variation and loads disturbances. A performance comparison between the proposed controller and a classical integral control scheme is carried out confirming the superiority of the proposed MPC technique.

  10. Mud, models, and managers: Reaching consensus on a watershed strategy for sediment load reduction

    Science.gov (United States)

    Wilcock, P. R.; Cho, S. J.; Gran, K.; Belmont, P.; Hobbs, B. F.; Heitkamp, B.; Marr, J. D.

    2017-12-01

    Agricultural nonpoint source sediment pollution is a leading cause of impairment of U.S. waters. Sediment sources are often on private land, such that solutions require not only considerable investment, but broad acceptance among landowners. We present the story of a participatory modeling exercise whose goal was to develop a consensus strategy for reducing sediment loading from the Greater Blue Earth River Basin, a large (9,200 km2) watershed in southern Minnesota dominated by row crop agriculture. The Collaborative for Sediment Source Reduction was a stakeholder group of farmers, industry representatives, conservation groups, and regulatory agencies. We used a participatory modeling approach to promote understanding of the problem, to define the scope of solutions acceptable to farmers, to develop confidence in a watershed model, and to reach consensus on a watershed strategy. We found that no existing watershed model could provide a reliable estimate of sediment response to management actions and developed a purpose-built model that could provide reliable, transparent, and fast answers. Because increased stream flow was identified as an important driver of sediment loading, the model and solutions included both hydrologic and sediment transport components. The model was based on an annual sediment budget with management actions serving to proportionally reduce both sediment sources and sediment delivery. Importantly, the model was developed in collaboration with stakeholders, such that a shared understanding emerged regarding of the modeling challenges and the reliability of information used to strongly constrain model output. The simplicity of the modeling approach supported stakeholder engagement and understanding, thereby lowering the social barrier between expert modeler and concerned stakeholder. The consensus strategy focused on water storage higher in the watershed in order to reduce river discharge and the large supply of sediment from near

  11. A multi-mode operation control strategy for flexible microgrid based on sliding-mode direct voltage and hierarchical controls.

    Science.gov (United States)

    Zhang, Qinjin; Liu, Yancheng; Zhao, Youtao; Wang, Ning

    2016-03-01

    Multi-mode operation and transient stability are two problems that significantly affect flexible microgrid (MG). This paper proposes a multi-mode operation control strategy for flexible MG based on a three-layer hierarchical structure. The proposed structure is composed of autonomous, cooperative, and scheduling controllers. Autonomous controller is utilized to control the performance of the single micro-source inverter. An adaptive sliding-mode direct voltage loop and an improved droop power loop based on virtual negative impedance are presented respectively to enhance the system disturbance-rejection performance and the power sharing accuracy. Cooperative controller, which is composed of secondary voltage/frequency control and phase synchronization control, is designed to eliminate the voltage/frequency deviations produced by the autonomous controller and prepare for grid connection. Scheduling controller manages the power flow between the MG and the grid. The MG with the improved hierarchical control scheme can achieve seamless transitions from islanded to grid-connected mode and have a good transient performance. In addition the presented work can also optimize the power quality issues and improve the load power sharing accuracy between parallel VSIs. Finally, the transient performance and effectiveness of the proposed control scheme are evaluated by theoretical analysis and simulation results. Copyright © 2015 ISA. Published by Elsevier Ltd. All rights reserved.

  12. Active load control techniques for wind turbines.

    Energy Technology Data Exchange (ETDEWEB)

    van Dam, C.P. (University of California, Davis, CA); Berg, Dale E.; Johnson, Scott J. (University of California, Davis, CA)

    2008-07-01

    This report provides an overview on the current state of wind turbine control and introduces a number of active techniques that could be potentially used for control of wind turbine blades. The focus is on research regarding active flow control (AFC) as it applies to wind turbine performance and loads. The techniques and concepts described here are often described as 'smart structures' or 'smart rotor control'. This field is rapidly growing and there are numerous concepts currently being investigated around the world; some concepts already are focused on the wind energy industry and others are intended for use in other fields, but have the potential for wind turbine control. An AFC system can be broken into three categories: controls and sensors, actuators and devices, and the flow phenomena. This report focuses on the research involved with the actuators and devices and the generated flow phenomena caused by each device.

  13. Low-Level RF Control of Microphonics in Superconducting Spoke-Loaded Cavities

    International Nuclear Information System (INIS)

    Conway, Z.A.; Kelly, M.P.; Sharamentov, S.I.; Shepard, K.W.; Davis, G.; Delayen, Jean; Doolittle, Lawrence

    2007-01-01

    This paper presents the results of cw RF frequency control and RF phase-stabilization experiments performed with a piezoelectric fast tuner mechanically coupled to a superconducting, 345 MHz, < = 0.5 triple-spoke-loaded cavity operating at 4.2K. The piezoelectric fast tuner damped low-frequency microphonic-noise by an order of magnitude. Two methods of RF phase-stabilization were characterized: overcoupling with negative phase feedback, and also fast mechanical tuner feedback. The = 0.5 triple-spoke-loaded cavity RF field amplitude and phase errors were controlled to ±0.5% and ±30 respectively.

  14. Partial storage optimization and load control strategy of cloud data centers.

    Science.gov (United States)

    Al Nuaimi, Klaithem; Mohamed, Nader; Al Nuaimi, Mariam; Al-Jaroodi, Jameela

    2015-01-01

    We present a novel approach to solve the cloud storage issues and provide a fast load balancing algorithm. Our approach is based on partitioning and concurrent dual direction download of the files from multiple cloud nodes. Partitions of the files are saved on the cloud rather than the full files, which provide a good optimization to the cloud storage usage. Only partial replication is used in this algorithm to ensure the reliability and availability of the data. Our focus is to improve the performance and optimize the storage usage by providing the DaaS on the cloud. This algorithm solves the problem of having to fully replicate large data sets, which uses up a lot of precious space on the cloud nodes. Reducing the space needed will help in reducing the cost of providing such space. Moreover, performance is also increased since multiple cloud servers will collaborate to provide the data to the cloud clients in a faster manner.

  15. Partial Storage Optimization and Load Control Strategy of Cloud Data Centers

    Science.gov (United States)

    2015-01-01

    We present a novel approach to solve the cloud storage issues and provide a fast load balancing algorithm. Our approach is based on partitioning and concurrent dual direction download of the files from multiple cloud nodes. Partitions of the files are saved on the cloud rather than the full files, which provide a good optimization to the cloud storage usage. Only partial replication is used in this algorithm to ensure the reliability and availability of the data. Our focus is to improve the performance and optimize the storage usage by providing the DaaS on the cloud. This algorithm solves the problem of having to fully replicate large data sets, which uses up a lot of precious space on the cloud nodes. Reducing the space needed will help in reducing the cost of providing such space. Moreover, performance is also increased since multiple cloud servers will collaborate to provide the data to the cloud clients in a faster manner. PMID:25973444

  16. INCA Modelling of the Lee System: strategies for the reduction of nitrogen loads

    Directory of Open Access Journals (Sweden)

    N. J. Flynn

    2002-01-01

    Full Text Available The Integrated Nitrogen Catchment model (INCA was applied successfully to simulate nitrogen concentrations in the River Lee, a northern tributary of the River Thames for 1995-1999. Leaching from urban and agricultural areas was found to control nitrogen dynamics in reaches unaffected by effluent discharges and abstractions; the occurrence of minimal flows resulted in an upward trend in nitrate concentration. Sewage treatment works (STW discharging into the River Lee raised nitrate concentrations substantially, a problem which was compounded by abstractions in the Lower Lee. The average concentration of nitrate (NO3 for the simulation period 1995-96 was 7.87 mg N l-1. Ammonium (NH4 concentrations were simulated less successfully. However, concentrations of ammonium rarely rose to levels which would be of environmental concern. Scenarios were run through INCA to assess strategies for the reduction of nitrate concentrations in the catchment. The conversion of arable land to ungrazed vegetation or to woodland would reduce nitrate concentrations substantially, whilst inclusion of riparian buffer strips would be unsuccessful in reducing nitrate loading. A 50% reduction in nitrate loading from Luton STW would result in a fall of up to 5 mg N l-1 in the reach directly affected (concentrations fell from maxima of 13 to 8 mg N l-1 , nearly a 40 % reduction, whilst a 20% reduction in abstractions would reduce maximum peaks in concentration in the lower Lee by up to 4 mg l-1 (from 17 to 13 mg N l-1, nearly a 25 % reduction,. Keywords: modelling, water quality, nitrogen, nitrate, ammonium, INCA, River Lee, River Thames, land-use.

  17. 40 CFR 52.1375 - Control strategy: Lead.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Lead. 52.1375 Section...) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Montana § 52.1375 Control strategy: Lead. Determination—EPA has determined that the East Helena Lead nonattainment area has attained the lead national...

  18. Tackling optimization challenges in industrial load control and full-duplex radios

    Science.gov (United States)

    Gholian, Armen

    In price-based demand response programs in smart grid, utilities set the price in accordance with the grid operating conditions and consumers respond to price signals by conducting optimal load control to minimize their energy expenditure while satisfying their energy needs. Industrial sector consumes a large portion of world electricity and addressing optimal load control of energy-intensive industrial complexes, such as steel industry and oil-refinery, is of practical importance. Formulating a general industrial complex and addressing issues in optimal industrial load control in smart grid is the focus of the second part of this dissertation. Several industrial load details are considered in the proposed formulation, including those that do not appear in residential or commercial load control problems. Operation under different smart pricing scenarios, namely, day-ahead pricing, time-of-use pricing, peak pricing, inclining block rates, and critical peak pricing are considered. The use of behind-the-meter renewable generation and energy storage is also considered. The formulated optimization problem is originally nonlinear and nonconvex and thus hard to solve. However, it is then reformulated into a tractable linear mixed-integer program. The performance of the design is assessed through various simulations for an oil refinery and a steel mini-mill. In the third part of this dissertation, a novel all-analog RF interference canceler is proposed. Radio self-interference cancellation (SIC) is the fundamental enabler for full-duplex radios. While SIC methods based on baseband digital signal processing and/or beamforming are inadequate, an all-analog method is useful to drastically reduce the self-interference as the first stage of SIC. It is shown that a uniform architecture with uniformly distributed RF attenuators has a performance highly dependent on the carrier frequency. It is also shown that a new architecture with the attenuators distributed in a clustered

  19. 40 CFR 52.58 - Control strategy: Lead.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control strategy: Lead. 52.58 Section...) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Alabama § 52.58 Control strategy: Lead. The lead plan... the lead standard throughout Alabama. The lead plan submitted by the State on October 7, 1985, and...

  20. Feedback control strategies for the Liu chaotic system

    International Nuclear Information System (INIS)

    Zhu Congxu; Chen Zhigang

    2008-01-01

    This Letter proposed three strategies of the dislocated feedback control, enhancing feedback control and speed feedback control of the Liu chaotic system to its unstable equilibrium points. It is found that the coefficients of enhancing feedback control and speed feedback control are smaller than those of ordinary feedback control, so, the complexity and cost of the system control are reduced. Theoretical analysis and numerical simulation are given, revealing the effectiveness of these strategies

  1. Study of Flexible Load Dispatch to Improve the Capacity of Wind Power Absorption

    Science.gov (United States)

    Yunlei, Yang; Shifeng, Zhang; Xiao, Chang; Da, Lei; Min, Zhang; Jinhao, Wang; Shengwen, Li; Huipeng, Li

    2017-05-01

    The dispatch method which track the trend of load demand by arranging the generation scheme of controllable hydro or thermal units faces great difficulties and challenges. With the increase of renewable energy sources such as wind power and photovoltaic power introduced to grid, system has to arrange much more spinning reserve units to compensate the unbalanced power. How to exploit the peak-shaving potential of flexible load which can be shifted with time or storage energy has become many scholars’ research direction. However, the modelling of different kinds of load and control strategy is considerably difficult, this paper choose the Air Conditioner with compressor which can storage energy in fact to study. The equivalent thermal parameters of Air Conditioner has been established. And with the use of “loop control” strategies, we can predict the regulated power of Air Conditioner. Then we established the Gen-Load optimal scheduling model including flexible load based on traditional optimal scheduling model. At last, an improved IEEE-30 case is used to verify. The result of simulation shows that flexible load can fast-track renewable power changes. More than that, with flexible load and reasonable incentive method to consumers, the operating cost of the system can be greatly cut down.

  2. Organosilane functionalization of halloysite nanotubes for enhanced loading and controlled release

    International Nuclear Information System (INIS)

    Yuan Peng; Southon, Peter D; Kepert, Cameron J; Liu Zongwen

    2012-01-01

    The surfaces of naturally occurring halloysite nanotubes were functionalized with γ-aminopropyltriethoxysilane (APTES), which was found to have a substantial effect on the loading and subsequent release of a model dye molecule. APTES was mostly anchored at the internal lumen surface of halloysite through covalent grafting, forming a functionalized surface covered by aminopropyl groups. The dye loading of the functionalized halloysite was 32% greater than that of the unmodified sample, and the release from the functionalized halloysite was dramatically prolonged as compared to that from the unmodified one. Dye release was prolonged at low pH and the release at pH 3.5 was approximately three times slower than that at pH 10.0. These results demonstrate that organosilane functionalization makes pH an external trigger for controlling the loading of guest on halloysite and the subsequent controlled release. (paper)

  3. Organosilane functionalization of halloysite nanotubes for enhanced loading and controlled release.

    Science.gov (United States)

    Yuan, Peng; Southon, Peter D; Liu, Zongwen; Kepert, Cameron J

    2012-09-21

    The surfaces of naturally occurring halloysite nanotubes were functionalized with γ-aminopropyltriethoxysilane (APTES), which was found to have a substantial effect on the loading and subsequent release of a model dye molecule. APTES was mostly anchored at the internal lumen surface of halloysite through covalent grafting, forming a functionalized surface covered by aminopropyl groups. The dye loading of the functionalized halloysite was 32% greater than that of the unmodified sample, and the release from the functionalized halloysite was dramatically prolonged as compared to that from the unmodified one. Dye release was prolonged at low pH and the release at pH 3.5 was approximately three times slower than that at pH 10.0. These results demonstrate that organosilane functionalization makes pH an external trigger for controlling the loading of guest on halloysite and the subsequent controlled release.

  4. Impact of working memory load on cognitive control in trait anxiety: an ERP study.

    Directory of Open Access Journals (Sweden)

    Senqing Qi

    Full Text Available Whether trait anxiety is associated with a general impairment of cognitive control is a matter of debate. This study investigated whether and how experimentally manipulated working memory (WM load modulates the relation between trait anxiety and cognitive control. This question was investigated using a dual-task design in combination with event-related potentials. Participants were required to remember either one (low WM load or six letters (high WM load while performing a flanker task. Our results showed that a high WM load disrupted participants' ability to overcome distractor interference and this effect was exacerbated for the high trait-anxious (HTA group. This exacerbation was reflected by larger interference effects (i.e., incongruent minus congruent on reaction times (RTs and N2 amplitudes for the HTA group than for the low trait-anxious group under high WM load. The two groups, however, did not differ in their ability to inhibit task-irrelevant distractors under low WM load, as indicated by both RTs and N2 amplitudes. These findings underscore the significance of WM-related cognitive demand in contributing to the presence (or absence of a general cognitive control deficit in trait anxiety. Furthermore, our findings show that when limited WM resources are depleted by high WM load, HTA individuals exhibit less efficient recruitments of cognitive control required for the inhibition of distractors, therefore resulting in a greater degree of response conflict.

  5. Controlled nanostructure and high loading of single-walled carbon nanotubes reinforced polycarbonate composite

    International Nuclear Information System (INIS)

    Wang Shiren; Liang Zhiyong; Pham, Giang; Park, Young-Bin; Wang, Ben; Zhang, Chuck; Kramer, Leslie; Funchess, Percy

    2007-01-01

    This paper presents an effective technique to fabricate thermoplastic nanocomposites with high loading of well-dispersed single-walled carbon nanotubes (SWNTs). SWNT membranes were made from a multi-step dispersion and filtration method, and then impregnated with polycarbonate solution to make thermoplastic nanocomposites. High loading of nanotubes was achieved by controlling the viscosity of polycarbonate solution. SEM and AFM characterization results revealed the controlled nanostructure in the resultant nanocomposites. Dynamic mechanical property tests indicated that the storage modulus of the resulting nanocomposites at 20 wt% nanotubes loading was improved by a factor of 3.4 compared with neat polycarbonate material. These results suggest the developed approach is an effective way to fabricate thermoplastic nanocomposites with good dispersion and high SWNT loading

  6. New load cycling strategy for enhanced durability of high temperature proton exchange membrane fuel cell

    DEFF Research Database (Denmark)

    Thomas, Sobi; Jeppesen, Christian; Steenberg, Thomas

    2017-01-01

    The objective of this paper is to develop a new operational strategy to increase the lifetime of a high temperature proton exchange membrane (HT-PEMFCs) fuel cell system by using load cycling patterns to reduce the phosphoric acid loss from the fuel cell. Four single cells were operated under.......8 Acm-2 for the higher end, were selected for the load cycling operation. The relaxation time, which is the period of time spent at low current density operation, is varied to understand how the performance over prolonged period behaves. The duration of the high current density operation is selected...... based on the relaxation time in order to have the same average current density of (0.55 Acm-2 ) for all the cells. Cell 5, with a relaxation time of 2 min performs best and shows lower degradation rate of 36 μVh-1 compared to other load cycling cells with smaller relaxation times. The cell operated...

  7. Second Order Washout filter based Power Sharing Strategy for Uninterruptible Power Supply

    DEFF Research Database (Denmark)

    Lu, Jinghang; Savaghebi, Mehdi; Guerrero, Josep M.

    2017-01-01

    In this paper, first, the existing frequency and voltage amplitude restoration control strategies are reviewed. Moreover, the proposed second order washout filter control strategy is proposed to enhance the dynamic response under load disturbance. The physical parameter of the proposed method is ...

  8. Energy Management Strategy for a Fuel Cell/ Ultracapasitor/ Battery Hybrid System for Portable Applications

    International Nuclear Information System (INIS)

    Siti Afiqah Abd Hamid; Ros Emilia Rosli; Edy Herianto Majlan; Wan Ramli Wan Daud; Ramizi Mohamed; Ramli Sitanggang

    2016-01-01

    A proton exchange membrane (PEM) fuel cells (FCs) with ultracapacitor (UC) and battery (BT) hybrid system has fast transient response compare to stand alone FCs. This hybrid system is promising candidates for environmentally friendly alternative energy sources. An energy management system design and control strategy was introduced in this study. The energy management strategy FC/ UC/ BT hybrid system model has been developed and the control strategy was programmed in the LabVIEWTM environment and implemented using National Instrument (NI) devices. The energy management strategy is able to manage the energy flow between the main power source (FCs) and auxiliary sources (UC and BT). To control the hybrid system and achieved proper performance, a controller circuit was developed with the three energy sources aligned in parallel to deliver the requested power. The developed model demonstrates the proportion power from the FC, UC and BT under various load demand. Experimental results demonstrate that FC/ UC/ BT hybrid system operated automatically with the varying load condition. The experimental results are presented; showing that the proposed strategy utilized the characteristic of both energy storage devices thus satisfies the load requirement. (author)

  9. 40 CFR 52.1681 - Control strategy: Lead.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Lead. 52.1681 Section...) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) New York § 52.1681 Control strategy: Lead. As part of the attainment demonstration for lead, the State of New York has committed to rate all sources...

  10. Improving Frequency Stability Based on Distributed Control of Multiple Load Aggregators

    DEFF Research Database (Denmark)

    Hu, Jianqiang; Cao, Jinde; Guerrero, Josep M.

    2017-01-01

    into the traditional centralized proportional-integral-based automatic generation control (AGC) framework, which has formed the coupled secondary frequency control structure. It has been shown that the total power mismatch in each control area is shared with both AGC units and load aggregators, and the system...

  11. Nonlinear control strategy based on using a shape-tunable neural controller

    Energy Technology Data Exchange (ETDEWEB)

    Chen, C.; Peng, S. [Feng Chia Univ, Taichung (Taiwan, Province of China). Department of chemical Engineering; Chang, W. [Feng Chia Univ, Taichung (Taiwan, Province of China). Department of Automatic Control

    1997-08-01

    In this paper, a nonlinear control strategy based on using a shape-tunable neural network is developed for adaptive control of nonlinear processes. Based on the steepest descent method, a learning algorithm that enables the neural controller to possess the ability of automatic controller output range adjustment is derived. The novel feature of automatic output range adjustment provides the neural controller more flexibility and capability, and therefore the scaling procedure, which is usually unavoidable for the conventional fixed-shape neural controllers, becomes unnecessary. The advantages and effectiveness of the proposed nonlinear control strategy are demonstrated through the challenge problem of controlling an open-loop unstable nonlinear continuous stirred tank reactor (CSTR). 14 refs., 11 figs.

  12. Relationship Between Strategy Shaping and Management Control Systems

    Directory of Open Access Journals (Sweden)

    Marcia Athayde Moreira

    2017-04-01

    Full Text Available This research analyzed the interactions between strategy shaping and management control systems, having as parameter of analysis the system of levers of control recommended by Simons (1995. A multiple case study was carried out of two companies in the construction sector in Brazil. It was found that these companies use generic niche strategies to sell the properties they have built. One of these companies uses long-term planning while the other is guided by short-term perspectives and perceptions. Both companies employ various formal control tools. It was noted, however, that some of these tools exist for the purpose of meeting the requirements of standards and audits established by certifying bodies and are not being used as tools for decision making. It was thus concluded that the relationship between managerial controls and the shaping of strategy in these organizations occurs in a passive way, with the management control systems serving as guarantors of the accomplishment of organizational strategies and goals, but not being used effectively to identify opportunities or as a source for shaping new strategies.

  13. Gust load alleviation wind tunnel tests of a large-aspect-ratio flexible wing with piezoelectric control

    Directory of Open Access Journals (Sweden)

    Ying Bi

    2017-02-01

    Full Text Available An active control technique utilizing piezoelectric actuators to alleviate gust-response loads of a large-aspect-ratio flexible wing is investigated. Piezoelectric materials have been extensively used for active vibration control of engineering structures. In this paper, piezoelectric materials further attempt to suppress the vibration of the aeroelastic wing caused by gust. The motion equation of the flexible wing with piezoelectric patches is obtained by Hamilton’s principle with the modal approach, and then numerical gust responses are analyzed, based on which a gust load alleviation (GLA control system is proposed. The gust load alleviation system employs classic proportional-integral-derivative (PID controllers which treat piezoelectric patches as control actuators and acceleration as the feedback signal. By a numerical method, the control mechanism that piezoelectric actuators can be used to alleviate gust-response loads is also analyzed qualitatively. Furthermore, through low-speed wind tunnel tests, the effectiveness of the gust load alleviation active control technology is validated. The test results agree well with the numerical results. Test results show that at a certain frequency range, the control scheme can effectively alleviate the z and x wingtip accelerations and the root bending moment of the wing to a certain extent. The control system gives satisfying gust load alleviation efficacy with the reduction rate being generally over 20%.

  14. Nonlinear Robust Control for Low Voltage Direct-Current Residential Microgrids with Constant Power Loads

    Directory of Open Access Journals (Sweden)

    Martín-Antonio Rodríguez-Licea

    2018-05-01

    Full Text Available A Direct Current (DC microgrid is a concept derived from a smart grid integrating DC renewable sources. The DC microgrids have three particularities: (1 integration of different power sources and local loads through a DC link; (2 on-site power source generation; and (3 alternating loads (on-off state. This kind of arrangement achieves high efficiency, reliability and versatility characteristics. The key device in the development of the DC microgrid is the power electronic converter (PEC, since it allows an efficient energy conversion between power sources and loads. However, alternating loads with strictly-controlled PECs can provide negative impedance behavior to the microgrid, acting as constant power loads (CPLs, such that the overall closed-loop system becomes unstable. Traditional CPL compensation techniques rely on a damping increment by the adaptation of the source or load voltage level, adding external circuitry or by using some advanced control technique. However, none of them provide a simple and general solution for the CPL problem when abrupt changes in parameters and/or in alternating loads/sources occur. This paper proposes a mathematical modeling and a robust control for the basic PECs dealing with CPLs in continuous conduction mode. In particular, the case of the low voltage residential DC microgrid with CPLs is taken as a benchmark. The proposed controller can be easily tuned for the desired response even by the non-expert. Basic converters with voltage mode control are taken as a basis to show the feasibility of this analysis, and experimental tests on a 100-W testbed include abrupt parameter changes such as input voltage.

  15. Design of a model predictive load-following controller by discrete optimization of control rod speed for PWRs

    International Nuclear Information System (INIS)

    Kim, Jae Hwan; Park, Soon Ho; Na, Man Gyun

    2014-01-01

    Highlights: • A model predictive controller for load-following operation was developed. • Genetic algorithm optimizes the five nonlinear discrete control rod speeds. • The boron concentration is adjusted with automatic adjustment logic. • The proposed controller reflects the realistic control rod drive mechanism movement. • The performance was confirmed to be satisfactory by simulation from BOC to EOC. - Abstract: Currently, most existing nuclear power plants alter the reactor power by adjusting the boron concentration in the coolant because it has a smaller effect on the reactor power distribution. Frequent control rod movements for load-following operation induce xenon-oscillation. Therefore, a controller that can subdue this phenomenon effectively is needed. At an APR1400 nuclear power plant which is a pressurized water reactor (PWR), the reactor power is controlled automatically using a Reactor Regulating System (RRS) but the power distribution is controlled manually by operators. Therefore, for APR+ nuclear power plants which is an improved version of APR1400 nuclear reactor, a new concept of a reactor controller is needed to control both the reactor power and power distribution automatically. The model predictive control (MPC) method is applicable to multiple-input multiple-output control, and can be applied for complex and nonlinear systems, such as the nuclear power plants. In this study, an MPC controller was developed by applying a genetic algorithm to optimize the discrete control rod speeds and by reflecting the realistic movement of the control rod drive mechanism that moves at only five discrete speeds. The performance of the proposed controller was confirmed to be satisfactory by simulating the load-following operation of an APR+ nuclear power plant through interface with KISPAC-1D code

  16. The effect of shoe design and lateral wedges on knee load and neuromuscular control in healthy subjects during walking

    DEFF Research Database (Denmark)

    Mølgaard, Carsten; Kersting, Uwe G.

    2014-01-01

    The increasing number of patients with developing osteoarthritis is accompanied by a growing scientific interest in non-operative early treatment strategies. It is generally believed that laterally wedged insoles can change the distribution of knee loading. However, the importance of footwear...... wedging is effective regardless of shoe design. Differences between the three neutral walking conditions underline the importance of footwear choice in individuals. It is safe to apply lateral wedges without jeopardising muscular control during walking regardless of shoe type. Possible effects of altering...

  17. The Study of Operation Modes and Control Strategies of a Multidirectional MC for Battery Based System

    Directory of Open Access Journals (Sweden)

    Saman Toosi

    2015-01-01

    Full Text Available To enhance the performance of stand-alone battery based system and to achieve the continuous power transmission, the behavior of multidirectional matrix converter (MDMC has been analyzed in different operation modes. A systematic method interfacing a renewable source, a storage battery, and a load is proposed for a stand-alone battery based power system (SABBPS to utilize the MDMC as PWM converter, inverter, or PWM converter and inverter in different operation modes. In this study, the Extended Direct Duty Pulse Width Modulation (EDDPWM technique has been applied to control the power flow path between the renewable source, load, and the battery. Corresponding to generator voltage, input frequency, and loads demands, several operating states and control strategies are possible. Therefore, the boundaries and distribution of operation modes are discussed and illustrated to improve the system performance. The mathematical equation of the EDDPWM under different operation modes has been derived to achieve the maximum voltage ratio in each mode. The theoretical and modulation concepts presented have been verified in simulation using MATLAB and experimental testing. Moreover, the THD, ripple, and power flow direction have been analyzed for output current to investigate the behavior of system in each operation mode.

  18. A randomized controlled trial of vitamin D dosing strategies after acute hip fracture: No advantage of loading doses over daily supplementation

    Directory of Open Access Journals (Sweden)

    Farrauto Leonardo

    2011-06-01

    Full Text Available Abstract Background There remains uncertainty regarding the appropriate therapeutic management of hip fracture patients. The primary aim of our study was to examine whether large loading doses in addition to daily vitamin D offered any advantage over a simple daily low-dose vitamin D regimen for increasing vitamin D levels. Methods In this randomized controlled study, patients over age 50 with an acute fragility hip fracture were enrolled from two hospital sites in Ontario, Canada. Participants were randomized to one of three loading dose groups: placebo; 50,000 IU vitamin D2; or 100,000 IU D2. Following a placebo/loading dose, all patients received a daily tablet of 1,000 IU vitamin D3 for 90 days. Serum 25-hydroxy vitamin D (25-OHD was measured at baseline, discharge from acute care (approximately 4-weeks, and 3-months. Results Sixty-five patients were enrolled in the study (44% male. An immediate rise in 25-OHD occurred in the 100,000 group, however there were no significant differences in 25-OHD between the placebo, 50,000 and 100,000 loading dose groups after 4-weeks (69.3, 84.5, 75.6 nmol/L, p = 0.15 and 3-months (86.7, 84.2, 73.3 nmol/L, p = 0.09, respectively. At the end of the study, approximately 75% of the placebo and 50,000 groups had reached the target therapeutic range (75 nmol/L, and 44% of the 100,000 group. Conclusions In correcting vitamin D insufficiency/deficiency in elderly patients with hip fracture, our findings suggest that starting with a lower daily dose of Vitamin D3 achieved similar results as providing an additional large loading dose of Vitamin D2. At the end of the study, all three groups were equally effective in attaining improvement in 25-OHD levels. Given that a daily dose of 1,000 IU vitamin D3 (with or without a loading dose resulted in at least 25% of patients having suboptimal vitamin D status, patients with acute hip fracture may benefit from a higher daily dose of vitamin D. Trial registration Clinical

  19. Impact of Battery Energy Storage System Operation Strategy on Power System: An Urban Railway Load Case under a Time-of-Use Tariff

    Directory of Open Access Journals (Sweden)

    Hyeongig Kim

    2017-01-01

    Full Text Available Customer-owned battery energy storage systems (BESS have been used to reduce electricity costs of energy storage owners (ESOs under a time-of-use (TOU tariff in Korea. However, the current TOU tariff can unintentionally induce customer’s electricity usage to have a negative impact on power systems. This paper verifies the impact of different BESS operation strategies on power systems under a TOU tariff by analyzing the TOU tariff structure and the customer’s load pattern. First, several BESS operation strategies of ESO are proposed to reduce the electricity cost. In addition, a degradation cost calculation method for lithium ion batteries is considered for the ESO to determine the optimal BESS operation strategy that maximizes both electricity cost and annual investment cost. The optimal BESS operation strategy that maximizes ESO’s net benefit is illustrated by simulation using an urban railway load data from Namgwangju Station, Korea. The results show that BESS connected to urban railway loads can negative impact power system operation. This is due to the high BESS degradation costs and lack of incentive of differential rates in TOU tariff that can effectively induce proper demand response.

  20. Constant DC-Capacitor Voltage-Control-Based Harmonics Compensation Strategy of Smart Charger for Electric Vehicles in Single-Phase Three-Wire Distribution Feeders

    Directory of Open Access Journals (Sweden)

    Fuka Ikeda

    2017-06-01

    Full Text Available This paper discusses harmonic current compensation of the constant DC-capacitor voltage-control (CDCVC-based strategy of smart chargers for electric vehicles (EVs in single-phase three-wire distribution feeders (SPTWDFs under nonlinear load conditions. The basic principle of the CDCVC-based harmonics compensation strategy under nonlinear load conditions is discussed in detail. The instantaneous power flowing into the three-leg pulse-width modulated (PWM rectifier, which performs as a smart charger, shows that the CDCVC-based strategy achieves balanced and sinusoidal source currents with a unity power factor. The CDCVC-based harmonics compensation strategy does not require any calculation blocks of fundamental reactive, unbalanced active, and harmonic currents. Thus, the authors propose a simplified algorithm to compensate for reactive, unbalanced active, and harmonic currents. A digital computer simulation is implemented to confirm the validity and high practicability of the CDCVC-based harmonics compensation strategy using PSIM software. Simulation results demonstrate that balanced and sinusoidal source currents with a unity power factor in SPTWDFs are obtained on the secondary side of the pole-mounted distribution transformer (PMDT during both the battery-charging and discharging operations in EVs, compensating for the reactive, unbalanced active, and harmonic currents.

  1. SP-100 initial startup and restart control strategy

    Science.gov (United States)

    Halfen, Frank J.; Wong, Kwok K.; Switick, Dennis M.; Shukla, Jaikaran N.

    Startup control strategies for SP-100 are described. Revised control and operating strategies are discussed which have been developed and tested using the SP-100 dynamic simulation model Aries-GFS (Generic Flight System).

  2. Implementation of Admittance Control on a Construction Robot using Load Cells

    DEFF Research Database (Denmark)

    Bekker, Misha; Pedersen, Rasmus; Bak, Thomas

    2018-01-01

    Physical human-robot interactions (pHRI) must be safe and should feel natural to the human operator. To this end impedance or admittance control is often employed to relate the force applied by the human to the dynamic behavior of the robot. The robot under consideration in this work uses a load...... cell to sense the externally applied force. This paper presents a practical modeling procedure and implementation of admittance control that specifically deal with the undesired non-linearities caused by the use of a load cell. Experiments are performed on a 1-DoF testbed to validate the work done...

  3. A comparison of WEC control strategies

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, David G. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Bacelli, Giorgio [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Coe, Ryan Geoffrey [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Bull, Diana L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Abdelkhalik, Ossama [Michigan Technological Univ., Houghton, MI (United States); Korde, Umesh A. [South Dakota School of Mines and Technology, Rapid City, SD (United States); Robinett, Rush D. [Michigan Technological Univ., Houghton, MI (United States)

    2016-04-01

    The operation of Wave Energy Converter (WEC) devices can pose many challenging problems to the Water Power Community. A key research question is how to significantly improve the performance of these WEC devices through improving the control system design. This report summarizes an effort to analyze and improve the performance of WEC through the design and implementation of control systems. Controllers were selected to span the WEC control design space with the aim of building a more comprehensive understanding of different controller capabilities and requirements. To design and evaluate these control strategies, a model scale test-bed WEC was designed for both numerical and experimental testing (see Section 1.1). Seven control strategies have been developed and applied on a numerical model of the selected WEC. This model is capable of performing at a range of levels, spanning from a fully-linear realization to varying levels of nonlinearity. The details of this model and its ongoing development are described in Section 1.2.

  4. Load consequences when sweeping blades - A case study of a 5 MW pitch controlled wind turbine

    Energy Technology Data Exchange (ETDEWEB)

    Verelst, D.R.S.; Larsen, Torben J.

    2010-08-15

    The generic 5 MW NREL wind turbine model is used in Risoe's aeroelastic simulator HAWC2 to investigate 120 different swept blade configurations (forward and backward sweep). Sensitivity for 2 different controllers is considered as well. Backward sweep results in a pitch to feather torsional moment of the blade, effectively reducing blade twist angles under increased loading. This behaviour results in decreased flap-wise fatigue and extreme loads, an increase for edge-wise fatigue loading and status quo or slight decrease in extreme loads (depending on the controller). Tower base and shaft-end bending moments are reduced as well. Forward sweep leads to an increase in angle of attack under loading. For a pitch controlled turbine this leads to an increase in fatigue and extreme loading in all cases. A controller inflicted instability is present for the more extreme forward swept cases. Due to the shape of considered sweep curves, an inherent and significant increase in torsional blade root bending moment is noted. A boomerang shaped sweep curve is proposed to counteract this problematic increased loading. Controller sensitivity shows that adding sweep affects some loadings differently. Power output is reduced for backward sweep since the blade twist is optimized as a rigid structure, ignoring the torsional deformations which for a swept blade can be significant. (author)

  5. AC Transmission Emulation Control Strategies for the BTB VSC HVDC System in the Metropolitan Area of Seoul

    Directory of Open Access Journals (Sweden)

    Sungyoon Song

    2017-08-01

    Full Text Available In the Korean power system, growing power loads have recently created the problems of voltage instability and fault current in the Seoul Capital Area (SCA. Accordingly, the back-to-back (BTB voltage source converter (VSC high-voltage direct-current (HVDC system is emerging to resolve such problems with grid segmentation. However, non-convergence problems occur in this metropolitan area, due to the large change of power flow in some contingencies. Therefore, this paper proposes two kinds of AC transmission emulation control (ATEC strategies to improve the metropolitan transient stability, and to resolve the non-convergence problem. The proposed ATEC strategies are able to mitigate possible overloading of adjacent AC transmission, and maintain power balance between metropolitan regions. The first ATEC strategy uses a monitoring system that permits the reverse power flow of AC transmission, and thus effectively improves the grid stability based on the power transfer equation. The second ATEC strategy emulates AC transmission with DC link capacitors in a permissible DC-link voltage range according to angle difference, and securely improves the gird stability, without requiring grid operator schedule decisions. This paper compares two kinds of ATEC schemes: it demonstrates the first ATEC strategy with specific fault scenario with PSS/E (Power Transmission System Planning Software, and evaluates the second ATEC strategy with internal controller performance with PSCAD/EMTDC (Power System Electromagnetic Transients Simulation Software.

  6. Deliberation's blindsight: how cognitive load can improve judgments.

    Science.gov (United States)

    Hoffmann, Janina A; von Helversen, Bettina; Rieskamp, Jörg

    2013-06-01

    Multitasking poses a major challenge in modern work environments by putting the worker under cognitive load. Performance decrements often occur when people are under high cognitive load because they switch to less demanding--and often less accurate--cognitive strategies. Although cognitive load disturbs performance over a wide range of tasks, it may also carry benefits. In the experiments reported here, we showed that judgment performance can increase under cognitive load. Participants solved a multiple-cue judgment task in which high performance could be achieved by using a similarity-based judgment strategy but not by using a more demanding rule-based judgment strategy. Accordingly, cognitive load induced a shift to a similarity-based judgment strategy, which consequently led to more accurate judgments. By contrast, shifting to a similarity-based strategy harmed judgments in a task best solved by using a rule-based strategy. These results show how important it is to consider the cognitive strategies people rely on to understand how people perform in demanding work environments.

  7. Mechanism of remote controlled after-loading radiotherapy unit

    International Nuclear Information System (INIS)

    Morimoto, Masaki

    1980-01-01

    Employing a small amount of Radium-226 or Cesium-137 source was to be used hitherto for the treatment of carcinoma of the uterine cervix in used After-loading techniques. It involved, however, radiation risk to the staff and patient. The long treatment time are also a pain (strain) on the patient. In recent years, we have developed a remote control after-loading unit, which was named as RALSTRON, which was complete eliminated the disadvantage of conventional radium therapy. This unit also has disadvantage, however, that the design for the remote after-loader for intracavitary applicators present considerable difficulties, because many sources of different active lengths and loading patterns are required. A solution to this problem was carried out by using small point source, placed in Tandem applicator, of high activity and moving them back slowly during the treatment. Recently, this unit was installed many hospitals about 80 units in Japan, and are used. In this paper are given about a mechanism and safety deviced of this unit. (author)

  8. Instructional Control of Cognitive Load in the Design of Complex Learning Environments

    NARCIS (Netherlands)

    Kester, Liesbeth; Paas, Fred; Van Merriënboer, Jeroen

    2010-01-01

    Kester, L., Paas, F., & Van Merriënboer, J. J. G. (2010). Instructional control of cognitive load in the design of complex learning environments. In J. L. Plass, R. Moreno, & Roland Brünken (Eds.), Cognitive Load Theory (pp. 109-130). New York: Cambridge University Press.

  9. Investigation of the maximum load alleviation potential using trailing edge flaps controlled by inflow data

    DEFF Research Database (Denmark)

    Fischer, Andreas; Aagaard Madsen, Helge

    2014-01-01

    The maximum fatigue load reduction potential when using trailing edge flaps on mega-watt wind turbines was explored. For this purpose an ideal feed forward control algorithm using the relative velocity and angle of attack at the blade to control the loads was implemented. The algorithm was applied...... to time series from computations with the aeroelastic code HAWC2 and to measured time series. The fatigue loads could be reduced by 36% in the computations if the in flow sensor was at the same position as the blade load. The decrease of the load reduction potential when the sensor was at a distance from...... the blade load location was investigated. When the algorithm was applied to measured time series a load reduction of 23% was achieved which is still promissing, but significantly lower than the value achieved in computations....

  10. Experimental Research and Control Strategy of Pumped Storage Units Dispatching in the Taiwan Power System Considering Transmission Line Limits

    Directory of Open Access Journals (Sweden)

    Ming-Tse Kuo

    2013-07-01

    Full Text Available Taiwan’s power system is isolated and not supported by other interconnected systems. Consequently, the system frequency immediately reflects changes in the system loads. Pumped storage units are crucial for controlling power frequency. These units provide main or auxiliary capacities, reducing the allocation of frequency-regulating reserve (FRR and further reducing generation costs in system operations. Taiwan’s Longmen Nuclear Power Plant is set to be converted for commercial operations, which will significantly alter the spinning reserves in the power system. Thus, this study proposes a safe and economic pumped storage unit dispatch strategy. This strategy is used to determine the optimal FRR capacity and 1-min recovery frequency in a generator failure occurrence at the Longmen Power Plant. In addition, this study considered transmission capacity constraints and conducted power flow analysis of the power systems in Northern, Central, and Southern Taiwan. The results indicated that, in the event of a failure at Longmen Power Plant, the proposed strategy can not only recover the system frequency to an acceptable range to prevent underfrequency load-shedding, but can also mitigate transmission line overloading.

  11. Robust Two Degrees-of-freedom Single-current Control Strategy for LCL-type Grid-Connected DG System under Grid-Frequency Fluctuation and Grid-impedance Variation

    DEFF Research Database (Denmark)

    Zhou, Leming; Chen, Yandong; Luo, An

    2016-01-01

    -of-freedom single-current control (RTDOF-SCC) strategy is proposed, which mainly includes the synchronous reference frame quasi-proportional-integral (SRFQPI) control and robust grid-current-feedback active damping (RGCFAD) control. The proposed SRFQPI control can compensate the local-loads reactive power......, and regulate the instantaneous grid current without steady-state error regardless of the fundamental frequency fluctuation. Simultaneously, the proposed RGCFAD control effectively damps the LCL-resonance peak regardless of the grid-impedance variation, and further improves both transient and steady...

  12. Real Time Energy Management Control Strategies for Hybrid Powertrains

    Science.gov (United States)

    Zaher, Mohamed Hegazi Mohamed

    In order to improve fuel efficiency and reduce emissions of mobile vehicles, various hybrid power-train concepts have been developed over the years. This thesis focuses on embedded control of hybrid powertrain concepts for mobile vehicle applications. Optimal robust control approach is used to develop a real time energy management strategy for continuous operations. The main idea is to store the normally wasted mechanical regenerative energy in energy storage devices for later usage. The regenerative energy recovery opportunity exists in any condition where the speed of motion is in opposite direction to the applied force or torque. This is the case when the vehicle is braking, decelerating, or the motion is driven by gravitational force, or load driven. There are three main concepts for regernerative energy storing devices in hybrid vehicles: electric, hydraulic, and flywheel. The real time control challenge is to balance the system power demand from the engine and the hybrid storage device, without depleting the energy storage device or stalling the engine in any work cycle, while making optimal use of the energy saving opportunities in a given operational, often repetitive cycle. In the worst case scenario, only engine is used and hybrid system completely disabled. A rule based control is developed and tuned for different work cycles and linked to a gain scheduling algorithm. A gain scheduling algorithm identifies the cycle being performed by the machine and its position via GPS, and maps them to the gains.

  13. Hierarchical Control Strategy for the Cooperative Braking System of Electric Vehicle

    OpenAIRE

    Peng, Jiankun; He, Hongwen; Liu, Wei; Guo, Hongqiang

    2015-01-01

    This paper provides a hierarchical control strategy for cooperative braking system of an electric vehicle with separated driven axles. Two layers are defined: the top layer is used to optimize the braking stability based on two sliding mode control strategies, namely, the interaxle control mode and signal-axle control strategies; the interaxle control strategy generates the ideal braking force distribution in general braking condition, and the single-axle control strategy can ensure braking s...

  14. Study of Pneumatic Servo Loading System in Double-Sided Polishing

    International Nuclear Information System (INIS)

    Qian, N; Ruan, J; Li, W

    2006-01-01

    The precise double-sided polishing process is one of the main methods to get the ultra-smooth surface of workpiece. In double-sided polishing machine, a loading system is required to be able to precisely control the load superimposed on the workpiece, while the polishing is being carried out. A pneumatic servo loading system is proposed for this purpose. In the pneumatic servo system, the servo valve, which acts both the electrical to mechanical converter and the power amplifier, has a substantial influence on the performance of the loading system. Therefore a specially designed pneumatic digital servo valve is applied in the control system. In this paper, the construction of the pneumatic servo loading system in double-sided polishing machine and control strategy associated with the digital servo valve are first addressed. The mathematical model of the system established and the hardware of the pneumatic servo system is designed. Finally, the experiments are carried out by measuring the practical load on the workpiece and the quality of the surface finish. It is demonstrated that the error rate of load is less than 5% and a super-smooth surface of silicon wafer with roughness Ra 0.401 nm can be obtained

  15. Decoupled Speed and Torque Control of IPMSM Drives Using a Novel Load Torque Estimator

    Directory of Open Access Journals (Sweden)

    ZAKY, M.

    2017-08-01

    Full Text Available This paper proposes decoupled speed and torque control of interior permanent magnet synchronous motor (IPMSM drives using a novel load torque estimator (LTE. The proposed LTE is applied for computing a load torque and yielding a feed-forward value in the speed controller to separate the torque control from the speed control. Indirect flux weakening using direct current component is obtained for high speed operation of the IPMSM drive, and its value for maximum torque per ampere (MTPA control in constant torque region is also used. LTE uses values of direct and quadrature currents to improve the behavior of the speed controller under the reference tracking and torque disturbances. The complete IPMSM drive by Matlab/Simulink is built. The effectiveness of the proposed control scheme using an experimental setup of the complete drive system implemented on a DSP-DS1102 control board is confirmed. Extensive results over a wide speed range are verified. The efficacy of the proposed method is confirmed in comparison to a conventional PI controller under both the reference speed tracking and load torque disturbance.

  16. An Efficient Modal Control Strategy for the Active Vibration Control of a Truss Structure

    Directory of Open Access Journals (Sweden)

    Ricardo Carvalhal

    2007-01-01

    Full Text Available In this paper an efficient modal control strategy is described for the active vibration control of a truss structure. In this approach, a feedback force is applied to each mode to be controlled according to a weighting factor that is determined by assessing how much each mode is excited by the primary source. The strategy is effective provided that the primary source is at a fixed position on the structure, and that the source is stationary in the statistical sense. To test the effectiveness of the control strategy it is compared with an alternative, established approach namely, Independent Modal Space Control (IMSC. Numerical simulations show that with the new strategy it is possible to significantly reduce the control effort required, with a minimal reduction in control performance.

  17. Influence of controlled immediate loading and implant design on peri-implant bone formation.

    Science.gov (United States)

    Vandamme, Katleen; Naert, Ignace; Geris, Liesbet; Vander Sloten, Jozef; Puers, Robert; Duyck, Joke

    2007-02-01

    Tissue formation at the implant interface is known to be sensitive to mechanical stimuli. The aim of the study was to compare the bone formation around immediately loaded versus unloaded implants in two different implant macro-designs. A repeated sampling bone chamber with a central implant was installed in the tibia of 10 rabbits. Highly controlled loading experiments were designed for a cylindrical (CL) and screw-shaped (SL) implant, while the unloaded screw-shaped (SU) implant served as a control. An F-statistic model with alpha=5% determined statistical significance. A significantly higher bone area fraction was observed for SL compared with SU (pimplant contact occurred was the highest for SL and significantly different from SU (pimplant contact was observed, a loading (SL versus SU: p=0.0049) as well as an implant geometry effect (SL versus CL: p=0.01) was found, in favour of the SL condition. Well-controlled immediate implant loading accelerates tissue mineralization at the interface. Adequate bone stimulation via mechanical coupling may account for the larger bone response around the screw-type implant compared with the cylindrical implant.

  18. Research of thermal dynamic characteristics for variable load single screw refrigeration compressor with different capacity control mechanism

    International Nuclear Information System (INIS)

    Wang, Zengli; Wang, Zhenbo; Wang, Jun; Jiang, Wenchun; Feng, Quanke

    2017-01-01

    Highlights: • Theoretical models of SSRC under part-load condition have been established. • The experiment of SSRC performance under part-load condition was conducted. • Thermal dynamic characteristic of SSRC under part-load condition was gained. • Economy and reliability of SSRC under part-load condition was analyzed. - Abstract: In the single screw refrigeration compressor (SSRC), the capacity control mechanism is normally employed to meet the actual required cooling capacity under different load conditions. In this paper, theoretical calculation models describing the working process of the SSRC with the single slide valve capacity control mechanism (SVCCM) and SSRC with the frequency conversion regulating mechanism (FCRM) are established to research the thermal dynamic characteristics for variable load SSRC under part-load conditions. Experimental investigation on a SSRC under part-load conditions is also carried out to verify the theoretical calculation models. By using these validated models, the thermodynamic performances and dynamic characteristics of the SSRC with different capacity control mechanism under part-load conditions have been analyzed and compared. Through the comparison, the economical efficiency and reliability of the SSRC with different capacity control mechanism were obtained. All of these works can provide the basis for the later optimization design for the variable load single screw refrigeration compressor.

  19. Tax Strategy Control

    DEFF Research Database (Denmark)

    Rossing, Christian Plesner

    2013-01-01

    This paper examines how a functional tax strategy impacts the management control system (MCS) in a multinational enterprise (MNE) facing transfer pricing tax risks. Based on case study findings it is argued that the MCS in a multinational setting is contingent upon the MNE's response to its tax...... environment. Moreover, the paper extends existing contingency-based theory on MCS by illustrating the role of inter-organisational network collaboration across MNE transfer pricing tax experts. This collaboration, caused by a widely dispersed tax knowledge base, fuels the formal interactive control system...... and reduces tax uncertainty. The paper adopts an interdisciplinary approach for explaining findings, using contingency-based theory and network theory at the inter-organisational level....

  20. Observer-Based Load Frequency Control for Island Microgrid with Photovoltaic Power

    Directory of Open Access Journals (Sweden)

    Chaoxu Mu

    2017-01-01

    Full Text Available As renewable energy is widely integrated into the power system, the stochastic and intermittent power generation from renewable energy may cause system frequency deviating from the prescribed level, especially for a microgrid. In this paper, the load frequency control (LFC of an island microgrid with photovoltaic (PV power and electric vehicles (EVs is investigated, where the EVs can be treated as distributed energy storages. Considering the disturbances from load change and PV power, an observer-based integral sliding mode (OISM controller is designed to regulate the frequency back to the prescribed value, where the neural network observer is used to online estimate the PV power. Simulation studies on a benchmark microgrid system are presented to illustrate the effectiveness of OISM controller, and comparative results also demonstrate that the proposed method has a superior performance for stabilizing the frequency over the PID control.

  1. Industrial strategy for nondestructive control

    International Nuclear Information System (INIS)

    Martin, P.; Michaut, J.P.

    1994-01-01

    For Electricite de France, the nondestructive control strategy passes by a responsibility of services, a competition between companies, a clarification of the market access and a dialogue with the companies

  2. Loads as a Resource: Frequency Responsive Demand

    Energy Technology Data Exchange (ETDEWEB)

    Kalsi, Karanjit [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hansen, Jacob [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Fuller, Jason C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Marinovici, Laurentiu D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Elizondo, Marcelo A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Williams, Tess L. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Lian, Jianming [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Sun, Yannan [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-12-01

    Current power grid operation predominantly relies on scheduling and regulating generation resources to supply loads and balance load changes. Due to the inherent intermittency of renewable energy, more flexible and fast ramping capacity is required to compensate for the uncertainty and variability introduced by renewable energy resources. With the advancement of information technologies, power system end-use loads are becoming more agile and can participate in provision of balancing energy and other grid services. The use of demand response can greatly reduce the required generation reserve in a clean and environmentally friendly way. In this report, a new frequency responsive load (FRL) controller was proposed based on the GFA controller, which can respond to both over and under-frequency events. A supervisory control was introduced to coordinate the autonomous response from FRLs in order to overcome the issues of excessive system response due to high penetration of FRLs. The effectiveness of the proposed FRL controller was demonstrated by large-scale simulation studies on the WECC system. Specifically, the FRLs were deployed in the WECC system at different penetration levels to analyze the performance of the proposed strategy both with and without supervisory level control. While both methods have their own advantages, the case without supervisory control could lead to system-wide instability depending on the size of the contingency and the number of FRLs deployed in the system. In addition, the voltage impacts of this controller on distribution system were also carefully investigated. Finally, a preliminary measurement and verification approach was also developed.

  3. Cooperative control for Ⅱdistrict power of wind turbine and aerodynamic load of blades%风电机组Ⅱ区功率与叶片气动载荷协同控制

    Institute of Scientific and Technical Information of China (English)

    王湘明; 任树平

    2017-01-01

    为了研究风力发电机组在低于额定功率时的最大风能捕获以及叶片的气动载荷,使得风力发电机组在整个生命周期内高效稳定地运行,提出了一种功率与载荷的协同控制方法,通过过渡区预变桨的方式控制风力发电机组功率与叶片气动载荷。采用所提出的功率与载荷协同控制策略在Matlab软件上搭建风力发电机组的仿真模型,计算得出了风力发电机组的功率和叶片气动载荷的数据,结果显示,协同控制策略能够在低于额定风速区域保持功率基本不变的情况下有效减小叶片的气动载荷,由此证明了所提出的协同控制策略的可行性。%In order to study the maximum wind power capture of wind turbine and the aerodynamic load of blades below the rated power and make the wind turbine run efficiently and stably in whole life cycle,a cooperative control method for both power and load was proposed.Through adopting the pre-pitch strategy in the transition zone,the aerodynamic load of blades and the power of wind turbine were controlled. Through adopting the proposed power and load cooperative strategy,a simulation model for the wind turbine was established with Matlab software,and the data for the power of wind turbine and the aerodynamic load of blades were calculated.The results show that the cooperative control strategy can effectively reduce the aerodynamic load of blades under the condition of keeping the power basically unchanged in the districts below the rated power.Therefore,the feasibility of the proposed cooperative control strategy is proved.

  4. Discrimination and anger control as pathways linking socioeconomic disadvantage to allostatic load in midlife.

    Science.gov (United States)

    Zilioli, Samuele; Imami, Ledina; Ong, Anthony D; Lumley, Mark A; Gruenewald, Tara

    2017-12-01

    Recent evidence suggests that experiences of discrimination contribute to socioeconomic status health disparities. The current study examined if the experience and regulation of anger-an expected emotional response to discrimination-serves as an explanatory factor for the previously documented links between socioeconomic disadvantage (SED), discrimination, and allostatic load. Data were drawn from the second wave of the Midlife in the United States (MIDUS) study and included 909 adults who participated in the biomarkers subproject. Results revealed that perceived discrimination was associated with higher levels of allostatic load. Furthermore, we found evidence that perceived discrimination and anger control sequentially explained the relationship between SED and allostatic load, such that greater discrimination was associated with lower levels of anger control, which, in turn accounted for the effects of discrimination on allostatic load. These results remained significant after controlling for negative affect, positive affect, other forms of anger expression, as well as demographic covariates. Our findings suggest that low anger control may be an important psychological pathway through which experiences of discrimination influence health. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Implementation strategy for the ITER plasma control system

    International Nuclear Information System (INIS)

    Winter, A.; Ambrosino, G.; Bauvir, B.; De Tommasi, G.; Humphreys, D.A.; Mattei, M.; Neto, A.; Raupp, G.; Snipes, J.A.; Stephen, A.V.; Treutterer, W.; Walker, M.L.; Zabeo, L.

    2015-01-01

    This paper gives an overview of the scope and context of the CODAC high-level real-time applications (Supervision and Plasma Control) and presents the strategy and current state of design of the tools to support the implementation. A real-time framework, which is currently under development with strong support of the worldwide fusion community will not only support the implementation of plasma control strategies with the extensive exception handling and forecasting functionality foreseen for ITER, but also integrated commissioning, orchestration and supervision as well as the real-time needs of ITER plant system developers. A second cornerstone in the implementation strategy is the development of a powerful simulation environment (Plasma Control System Simulation Platform – PCSSP) to design and verify control strategies, event handling and orchestration and automation. The development of PCSSP is currently under contract and this paper will also give an overview of its current state of development.

  6. Implementation strategy for the ITER plasma control system

    Energy Technology Data Exchange (ETDEWEB)

    Winter, A., E-mail: axel.winter@iter.org [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St Paul Lez Durance Cedex (France); Ambrosino, G. [CREATE/Università di Napoli Federico II, Dip. Ingegneria Elettrica e delle Tecnologie dell’Informazione (Italy); Bauvir, B. [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St Paul Lez Durance Cedex (France); De Tommasi, G. [CREATE/Università di Napoli Federico II, Dip. Ingegneria Elettrica e delle Tecnologie dell’Informazione (Italy); Humphreys, D.A. [General Atomics, San Diego, CA (United States); Mattei, M. [CREATE/Seconda Università di Napoli, Dip. Ingegneria Industriale e dell’Informazione (Italy); Neto, A. [Fusion for Energy, Barcelona (Spain); Raupp, G. [Max Planck Institute for Plasma Physics, EURATOM Association, Garching (Germany); Snipes, J.A. [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St Paul Lez Durance Cedex (France); Stephen, A.V. [Culham Centre for Fusion Energy, Culham Science Centre, Abingdon (United Kingdom); Treutterer, W. [Max Planck Institute for Plasma Physics, EURATOM Association, Garching (Germany); Walker, M.L. [General Atomics, San Diego, CA (United States); Zabeo, L. [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St Paul Lez Durance Cedex (France)

    2015-10-15

    This paper gives an overview of the scope and context of the CODAC high-level real-time applications (Supervision and Plasma Control) and presents the strategy and current state of design of the tools to support the implementation. A real-time framework, which is currently under development with strong support of the worldwide fusion community will not only support the implementation of plasma control strategies with the extensive exception handling and forecasting functionality foreseen for ITER, but also integrated commissioning, orchestration and supervision as well as the real-time needs of ITER plant system developers. A second cornerstone in the implementation strategy is the development of a powerful simulation environment (Plasma Control System Simulation Platform – PCSSP) to design and verify control strategies, event handling and orchestration and automation. The development of PCSSP is currently under contract and this paper will also give an overview of its current state of development.

  7. Automatic control of the water level of steam generators from 0% to 100% of the load

    International Nuclear Information System (INIS)

    Hocepied, R.; Debelle, J.; Timmermans, A.; Lams, J.-L.; Baeyens, R.; Eussen, G.; Bassem, G.

    1978-01-01

    The water level of a steam generator is hard to control manually and it is practically impossible for a human operator to react correctly to every important perturbation. These phenomena are further accentuated during the start-up at low load and at low feedwater temperature. The control schemes traditionally provided do not permit satisfactory automatic level control during all operating circumstances. Adaptions of the control system permit all the problems encountered to be solved: automatic control of the level in the steam generators is possible from 0% to 100% of the load and also when large-scale perturbations occur. Such a result has been obtained by use of systematic methods for the analysis of the steam generator's behaviour. These methods have also been used to verify the performance of the control system. The control system installed at the Doel nuclear power station prevents most of the reactor or turbine trip-outs caused by level deviations occurring during start-up and low-load operation. It also minimizes the effects on the unit of incidents such as tripping the unit on house load, safety tripping, fast run-back on reduced load, etc. The principles used are applicable to the control of steam generators of all pressurized water reactor power stations. (author)

  8. Dynamic performance improvement of standalone battery integrated PMSG wind energy system using proportional resonant controller

    Directory of Open Access Journals (Sweden)

    Dileep Kumar Varma Sagiraju

    2017-08-01

    Full Text Available The load voltage and frequency should be controlled under steady state and transient conditions in off grid applications. Power quality and power management is very important task for rural communities under erratic wind and load conditions. This paper presents a coordinated Proportional resonant (PR and battery energy controller for enhancement of power quality and power management in direct drive standalone wind energy system. The dynamic performance of standalone direct drive Permanent Magnet Synchronous Generator (PMSG is investigated with the proposed control scheme under various operating conditions such as fluctuating wind with step increase and decrease in wind velocity, balanced and unbalanced load conditions. The proposed PR control strategy with battery energy controller also ensures effective power balance between wind and battery source in order to fulfill the load demand. The superiority of the proposed control strategy is confirmed by comparing with the traditional vector control strategy under fluctuating wind and load conditions through MATLAB/SIMULINK platform.

  9. Anti-tobacco control industry strategies in Turkey.

    Science.gov (United States)

    Keklik, Seda; Gultekin-Karakas, Derya

    2018-02-26

    Transnational tobacco companies (TTCs) penetrated the Turkish cigarette market due to trade and investment liberalization in the post-1980 period and eventually secured full control. Despite tobacco control policies put in place in reaction to accelerating consumption, TTCs reinforced their market power through a variety of strategies. This paper explores industry strategies that counteract tobacco control policies in Turkey. The study employs both qualitative and quantitative analyses to explore industry strategies in Turkey. Besides the content analyses of industry and market reports, descriptive analyses were conducted for the sub-periods of 1999-2015. The analyses focus on the market strategies of product innovation, advertisement-promotion, cost management and pricing. Rising sales of low tar, ultra-low tar, slim, super-slim and flavoured cigarettes indicate that product innovation served to sustain consumption. Besides, the tobacco industry, using its strong distribution channels, the Internet, and CSR projects, were found to have promoted smoking indirectly. The industry also rationalized manufacturing facilities and reduced the cost of tobacco, making Turkey a cigarette-manufacturing base. Tobacco manufacturers, moreover, offered cigarettes in different price segments and adjusted net prices both up and down according to price categories and market conditions. In response to the successful effect of shifts in price margins, the market share of mid-priced cigarettes expanded while those within the economy category maintained the highest market share. As a result of pricing strategies, net sales revenues increased. Aside from official cigarette sales, the upward trends in the registered and unregistered sales of cigarette substitutes indicate that the demand-side tobacco control efforts remain inadequate. The Turkish case reveals that the resilience of the tobacco industry vis-à-vis mainstream tobacco control efforts necessitates a new policy perspective

  10. Control of disturbing loads in residential and commercial buildings via geometric algebra.

    Science.gov (United States)

    Castilla, Manuel-V

    2013-01-01

    Many definitions have been formulated to represent nonactive power for distorted voltages and currents in electronic and electrical systems. Unfortunately, no single universally suitable representation has been accepted as a prototype for this power component. This paper defines a nonactive power multivector from the most advanced multivectorial power theory based on the geometric algebra (GA). The new concept can have more importance on harmonic loads compensation, identification, and metering, between other applications. Likewise, this paper is concerned with a pioneering method for the compensation of disturbing loads. In this way, we propose a multivectorial relative quality index δ(~) associated with the power multivector. It can be assumed as a new index for power quality evaluation, harmonic sources detection, and power factor improvement in residential and commercial buildings. The proposed method consists of a single-point strategy based of a comparison among different relative quality index multivectors, which may be measured at the different loads on the same metering point. The comparison can give pieces of information with magnitude, direction, and sense on the presence of disturbing loads. A numerical example is used to illustrate the clear capabilities of the suggested approach.

  11. Automatic Control of Reactor Temperature and Power Distribution for a Daily Load following Operation

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Keuk Jong; Kim, Han Gon [Korea Hydro and Nuclear Power Institute, Daejeon (Korea, Republic of)

    2010-10-15

    An automatic control method of reactor power and power distribution was developed for a daily load following operation of APR1400. This method used a model predictive control (MPC) methodology having second-order plant data. And it utilized a reactor power ratio and axial shape index as control variables. However, the reactor regulating system of APR1400 is operated by the difference between the average temperature of the reactor core and the reference temperature, which is proportional to the turbine load. Thus, this paper reports on the model predictive control methodology using fourth-order plant data and a reactor temperature instead of the reactor power shape. The purpose of this study is to develop a revised automatic controller and analyze the behavior of the nuclear reactor temperature (Tavg) and the axial shape index (ASI) using the MPC method during a daily load following operation

  12. Influence of the control system on wind turbine loads during power production in extreme turbulence: Structural reliability

    DEFF Research Database (Denmark)

    Abdallah, Imad; Natarajan, Anand; Sørensen, John Dalsgaard

    2016-01-01

    structural reliability are assessed when the extreme turbulence model is uncertain. The structural reliability is assessed for the wind turbine when three configurations of an industrial grade load alleviation control system of increasing complexity and performance are used. The load alleviation features......The wind energy industry is continuously researching better computational models of wind inflow and turbulence to predict extreme loading (the nature of randomness) and their corresponding probability of occurrence. Sophisticated load alleviation control systems are increasingly being designed...... and deployed to specifically reduce the adverse effects of extreme load events resulting in lighter structures. The main objective herein is to show that despite large uncertainty in the extreme turbulence models, advanced load alleviation control systems yield both a reduction in magnitude and scatter...

  13. On Control Strategies for Responsive Architectural Structures

    DEFF Research Database (Denmark)

    Kirkegaard, Poul Henning; Parigi, Dario

    2012-01-01

    The present paper considers control of responsive architectural structures for improvement of structural performance by recognizing changes in their environments and loads, adapting to meet goals, and using past events to improve future performance or maintain serviceability. The general scope of...

  14. Scheduling of radio-controlled heating load

    International Nuclear Information System (INIS)

    Fox, B.; McCartney, A.I.; McCann, B.M.

    1998-01-01

    An economic loading program has been adapted to enable it to obtain an optimum heat-load profile to meet the forecast heat requirement. The heat load is represented by a 'generator' whose load is constrained to be negative. The incremental cost of this unit is a heat energy price. This is adjusted to obtain a heat profile containing the requisite energy. The profile is then used by a dynamic programming algorithm to derive a commitment pattern for each block. A case study is presented which shows that the procedure can minimise heat energy cost. It is also shown that use of the proposed method results in less generator load cycling. This reduced regulation duty should improve reliability. (author)

  15. ANN based controller for three phase four leg shunt active filter for power quality improvement

    Directory of Open Access Journals (Sweden)

    J. Jayachandran

    2016-03-01

    Full Text Available In this paper, an artificial neural network (ANN based one cycle control (OCC strategy is proposed for the DSTATCOM shunted across the load in three phase four wire distribution system. The proposed control strategy mitigates harmonic/reactive currents, ensures balanced and sinusoidal source current from the supply mains that are nearly in phase with the supply voltage and compensates neutral current under varying source and load conditions. The proposed control strategy is superior over conventional methods as it eliminates, the sensors needed for sensing load current and coupling inductor current, in addition to the multipliers and the calculation of reference currents. ANN controllers are implemented to maintain voltage across the capacitor and as a compensator to compensate neutral current. The DSTATCOM performance is validated for all possible conditions of source and load by simulation using MATLAB software and simulation results prove the efficacy of the proposed control over conventional control strategy.

  16. 40 CFR 52.65 - Control Strategy: Nitrogen oxides.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control Strategy: Nitrogen oxides. 52.65 Section 52.65 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Alabama § 52.65 Control Strategy: Nitrogen...

  17. Strategy for solving a coupled problem of the electromagnetic load analysis and design optimization for local conducting structures to support the ITER blanket development

    International Nuclear Information System (INIS)

    Rozov, Vladimir; Belyakov, V.; Kukhtin, V.; Lamzin, E.; Mazul, I.; Sytchevsky, S.

    2014-01-01

    Highlights: • We present the way of modeling transient electro-magnetic loads on local conductive domains in the large magnetic system. • Simplification is achieved by decomposing of the problem, multi-scale integral-differential modeling and use of integral parameters. • The intrinsic scale of loads on a localized conductor with eddy is quantified through the load susceptibility tensor. • Solution is searched as response of a simple equivalent dynamic simulator, using control theory methods. • The concept is exemplified with multi-scenario assessment of EM eddy loads on ITER blanket modules. - Abstract: The complexity of the electromagnetic (EM) response of the tokamak structures is one of the key and design-driving issues for the ITER. We consider the specifics of the assessment of ponderomotive forces, acting on local components of a large electro-physical device during electromagnetic transients. A strategy and approach is proposed for the operative EM loads modeling and analysis that enables design optimization at early phases of development. The paper describes a method of principal simplification of the mathematical model, based on the analysis and exploiting specific features and peculiarities of the relevant technical problem, determined by the design and operation of the device and system under consideration. The application of the method for predictive EM loads analysis and corresponding numerical calculations are exemplified for the localized ITER blanket components — shield modules. The example demonstrates the efficiency of EM load analysis in complex electromagnetic systems via a set of simplified models with different scope, contents and level of detail

  18. Strategy for solving a coupled problem of the electromagnetic load analysis and design optimization for local conducting structures to support the ITER blanket development

    Energy Technology Data Exchange (ETDEWEB)

    Rozov, Vladimir, E-mail: vladimir.rozov@iter.org [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul-lez-Durance (France); Belyakov, V.; Kukhtin, V.; Lamzin, E.; Mazul, I.; Sytchevsky, S. [D.V. Efremov Scientific Research Institute, 196641 St. Petersburg (Russian Federation)

    2014-11-15

    Highlights: • We present the way of modeling transient electro-magnetic loads on local conductive domains in the large magnetic system. • Simplification is achieved by decomposing of the problem, multi-scale integral-differential modeling and use of integral parameters. • The intrinsic scale of loads on a localized conductor with eddy is quantified through the load susceptibility tensor. • Solution is searched as response of a simple equivalent dynamic simulator, using control theory methods. • The concept is exemplified with multi-scenario assessment of EM eddy loads on ITER blanket modules. - Abstract: The complexity of the electromagnetic (EM) response of the tokamak structures is one of the key and design-driving issues for the ITER. We consider the specifics of the assessment of ponderomotive forces, acting on local components of a large electro-physical device during electromagnetic transients. A strategy and approach is proposed for the operative EM loads modeling and analysis that enables design optimization at early phases of development. The paper describes a method of principal simplification of the mathematical model, based on the analysis and exploiting specific features and peculiarities of the relevant technical problem, determined by the design and operation of the device and system under consideration. The application of the method for predictive EM loads analysis and corresponding numerical calculations are exemplified for the localized ITER blanket components — shield modules. The example demonstrates the efficiency of EM load analysis in complex electromagnetic systems via a set of simplified models with different scope, contents and level of detail.

  19. The EU-strategy against soil acidification. Concept of the critical load; Die EU-Strategie gegen Bodenversauerung. Konzept der kritischen Belastung

    Energy Technology Data Exchange (ETDEWEB)

    Trautwein, W.P.

    1998-10-01

    The development of so-called `novel forest damages` is considered to be - at least partly - a result of the impact of certain air pollutants such as sulphur and nitrogen oxides; these precipitate as acid rain and acidify the soil, thus damaging sensitive ecosystems, e.g. forests. To combat acidification, the EU Commission has produced a Community strategy, which is based on the concept of critical loads. The DGMK report 548 deals with this concept of critical loads and with the measures to combat soil acidifiction. It explains that critical loads are not damage thresholds, but environmental standards, and deviation does not necessarily required any action. It demonstrates, why the reduction of sulphur dioxide emissions, formed during the utilization of fluid fuels, is not a cost-effective measures. It proposes continued implementation of agreed plans for emission reduction, before additional legislative steps are considered. This report contains information to June 1998 inclusive. (orig.) [Deutsch] Die Entstehung der sogenannten `neuartigen Waldschaeden` fuehrt man zum Teil auf die Einwirkung gewisser Luftschadstoffe wie Schwefel- und Stickoxide zurueck, die als saurer Regen auf die Erde niedergehen und zu einer Versauerung des Bodens und damit zu einer Schaedigung empfindlicher Oekosysteme wie der Waelder fuehren koennen. Die EU-Kommission hat eine Strategie der EU zur Bekaempfung dieser Versauerung entwickelt, die auf dem Konzept der kritischen Belastungen beruht. Der DGMK-Bericht 548 setzt sich mit diesem Konzept der kritischen Belastungen sowie mit den Massnahmen zur Bekaempfung der Bodenversauerung auseinander. Er erlaeutert, dass kritische Belastungen keinen Schwellenwert, sondern einen Umweltstandard darstellen, aus dessen Ueberschreitung nicht zwingend ein Handlungsbedarf abgeleitet werden kann. Er erlaeutert ferner, warum vor allem die Reduktion der Schwefeldioxidemissionen, die beim Einsatz fluessiger Kraft- und Brennstoffe entstehen, keine

  20. A modification of a conventional feed water three-element control strategy to solve problems of drum level control; Una modificacion de un sistema convencional de control de agua de alimentacion de tres elementos para resolver problemas de control de nivel del tambor

    Energy Technology Data Exchange (ETDEWEB)

    Delgadillo Valencia, Miguel Angel; Hernandez Cuellar, Maria Aurora [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2008-07-01

    A control strategy for the drum level control of a combined cycle power plant is presented. This strategy is based on the conventional three element system with variable proportional gain in the master and slave controllers. The dynamic behavior of the proposed strategy is compared with a former one showing a better answer especially at full load (generated electric energy) with the supplementary fire (duct burners or after burners) in operation. When the feed water control valve is near its full opening, this strategy can avoid as much as possible the saturation of the control signal to the valve, with elimination of the permanent oscillation of the controlled variable (drum level). The control system behavior also shows good stability from start up to full load, including the transition from one to three elements operating mode and vice verse, as well as the duct burners' ignition. Similar stability is shown during the stop of the Heat Recovery Steam Generator (HRSG) from full load with duct fire in operation to the HRSG out of service. Due to the performance of the blocks communication software of the commercial equipment in use, a transition band of the steam flow signal is proposed, in order to assure a three to one or one to three element bump less transfer operation. Simulation laboratory tests were applied to the proposed control strategy with a simplified dynamic process model, before the control system was put into operation in site. Real process runs and the control-tune parameters are presented. [Spanish] Estudios de investigacion muestran interes en resolver problemas de inestabilidad de control de nivel, en generadores de vapor de plantas generadoras de energia electrica, disenando modelos del fenomeno del nivel del domo, para establecer una estrategia de control para sistemas de control de agua de alimentacion. Sin embargo, una estrategia de control basada en un modelo puede ser dificil de entender para los ingenieros de control, especialmente