WorldWideScience

Sample records for living small animals

  1. Animals In Synchrotrons: Overcoming Challenges For High-Resolution, Live, Small-Animal Imaging

    International Nuclear Information System (INIS)

    Donnelley, Martin; Parsons, David; Morgan, Kaye; Siu, Karen

    2010-01-01

    Physiological studies in small animals can be complicated, but the complexity is increased dramatically when performing live-animal synchrotron X-ray imaging studies. Our group has extensive experience in high-resolution live-animal imaging at the Japanese SPring-8 synchrotron, primarily examining airways in two-dimensions. These experiments normally image an area of 1.8 mmx1.2 mm at a pixel resolution of 0.45 μm and are performed with live, intact, anaesthetized mice.There are unique challenges in this experimental setting. Importantly, experiments must be performed in an isolated imaging hutch not specifically designed for small-animal imaging. This requires equipment adapted to remotely monitor animals, maintain their anesthesia, and deliver test substances while collecting images. The horizontal synchrotron X-ray beam has a fixed location and orientation that limits experimental flexibility. The extremely high resolution makes locating anatomical regions-of-interest slow and can result in a high radiation dose, and at this level of magnification small animal movements produce motion-artifacts that can render acquired images unusable. Here we describe our experimental techniques and how we have overcome several challenges involved in performing live mouse synchrotron imaging.Experiments have tested different mouse strains, with hairless strains minimizing overlying skin and hair artifacts. Different anesthetics have also be trialed due to the limited choices available at SPring-8. Tracheal-intubation methods have been refined and controlled-ventilation is now possible using a specialized small-animal ventilator. With appropriate animal restraint and respiratory-gating, motion-artifacts have been minimized. The animal orientation (supine vs. head-high) also appears to affect animal physiology, and can alter image quality. Our techniques and image quality at SPring-8 have dramatically improved and in the near future we plan to translate this experience to the

  2. Reaction-based small-molecule fluorescent probes for dynamic detection of ROS and transient redox changes in living cells and small animals.

    Science.gov (United States)

    Lü, Rui

    2017-09-01

    Dynamic detection of transient redox changes in living cells and animals has broad implications for human health and disease diagnosis, because intracellular redox homeostasis regulated by reactive oxygen species (ROS) plays important role in cell functions, normal physiological functions and some serious human diseases (e.g., cancer, Alzheimer's disease, diabetes, etc.) usually have close relationship with the intracellular redox status. Small-molecule ROS-responsive fluorescent probes can act as powerful tools for dynamic detection of ROS and redox changes in living cells and animals through fluorescence imaging techniques; and great advances have been achieved recently in the design and synthesis of small-molecule ROS-responsive fluorescent probes. This article highlights up-to-date achievements in designing and using the reaction-based small-molecule fluorescent probes (with high sensitivity and selectivity to ROS and redox cycles) in the dynamic detection of ROS and transient redox changes in living cells and animals through fluorescence imaging. Copyright © 2017. Published by Elsevier Ltd.

  3. Small Animal [18F]FDG PET Imaging for Tumor Model Study

    International Nuclear Information System (INIS)

    Woo, Sang Keun; Kim, Kyeong Min; Cheon, Gi Jeong

    2008-01-01

    PET allows non-invasive, quantitative and repetitive imaging of biological function in living animals. Small animal PET imaging with [ 18 F]FDG has been successfully applied to investigation of metabolism, receptor, ligand interactions, gene expression, adoptive cell therapy and somatic gene therapy. Experimental condition of animal handling impacts on the biodistribution of [ 18 F]FDG in small animal study. The small animal PET and CT images were registered using the hardware fiducial markers and small animal contour point. Tumor imaging in small animal with small animal [ 18 F]FDG PET should be considered fasting, warming, and isoflurane anesthesia level. Registered imaging with small animal PET and CT image could be useful for the detection of tumor. Small animal experimental condition of animal handling and registration method will be of most importance for small lesion detection of metastases tumor model

  4. Implementation of immobilization accessories for positioning of small animals for radiation therapy

    International Nuclear Information System (INIS)

    Vettorato, M.C.; Girotto, C.H.; Fogaça, J.L.; Vulcano, L.C.; Fernandes, M.A.R.

    2017-01-01

    Radiation therapy is a modality that is presenting great advances in veterinary medicine worldwide. In Brazil, this therapeutic option is underachieved. The success of this method depends on several factors, including the use of appropriate accessories for protection and immobilization of patients. For the immobilization of small animals during treatment, in addition to sedation and anesthesia, immobilizing accessories, similar to those used in human radiotherapy, are used. This study aimed to present proposals for immobilizing accessories adapted to the positioning of small animals in order to be used in radiotherapy planning. In order to achieve results, accessories were made and tested in a living animal simulating a radiotherapy planning, which proved to be favorable to use in positioning small animals undergoing radiotherapy and for implementation processes. (author)

  5. Implementation of immobilization accessories for positioning of small animals for radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Vettorato, M.C.; Girotto, C.H.; Fogaça, J.L.; Vulcano, L.C.; Fernandes, M.A.R., E-mail: m_vettorato@hotmail.com [Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP), Botucatu, SP (Brazil)

    2017-11-15

    Radiation therapy is a modality that is presenting great advances in veterinary medicine worldwide. In Brazil, this therapeutic option is underachieved. The success of this method depends on several factors, including the use of appropriate accessories for protection and immobilization of patients. For the immobilization of small animals during treatment, in addition to sedation and anesthesia, immobilizing accessories, similar to those used in human radiotherapy, are used. This study aimed to present proposals for immobilizing accessories adapted to the positioning of small animals in order to be used in radiotherapy planning. In order to achieve results, accessories were made and tested in a living animal simulating a radiotherapy planning, which proved to be favorable to use in positioning small animals undergoing radiotherapy and for implementation processes. (author)

  6. Technology challenges in small animal PET imaging

    International Nuclear Information System (INIS)

    Lecomte, Roger

    2004-01-01

    Positron Emission Tomography (PET) is a non-invasive nuclear imaging modality allowing biochemical processes to be investigated in vivo with sensitivity in the picomolar range. For this reason, PET has the potential to play a major role in the emerging field of molecular imaging by enabling the study of molecular pathways and genetic processes in living animals non-invasively. The challenge is to obtain a spatial resolution that is appropriate for rat and mouse imaging, the preferred animal models for research in biology, while achieving a sensitivity adequate for real-time measurement of rapid dynamic processes in vivo without violating tracer kinetic principles. An overview of the current state of development of dedicated small animal PET scanners is given, and selected applications are reported and discussed with respect to performance and significance to research in biology

  7. Small-Animal Imaging Using Diffuse Fluorescence Tomography.

    Science.gov (United States)

    Davis, Scott C; Tichauer, Kenneth M

    2016-01-01

    Diffuse fluorescence tomography (DFT) has been developed to image the spatial distribution of fluorescence-tagged tracers in living tissue. This capability facilitates the recovery of any number of functional parameters, including enzymatic activity, receptor density, blood flow, and gene expression. However, deploying DFT effectively is complex and often requires years of know-how, especially for newer mutlimodal systems that combine DFT with conventional imaging systems. In this chapter, we step through the process of using MRI-DFT imaging of a receptor-targeted tracer in small animals.

  8. Living with the animals: animal or robotic companions for the elderly in smart homes?

    Science.gov (United States)

    Preuß, Dirk; Legal, Friederike

    2017-06-01

    Although the use of pet robots in senior living facilities and day-care centres, particularly for individuals suffering from dementia, has been intensively researched, the question of introducing pet robots into domestic settings has been relatively neglected. Ambient assisted living (AAL) offers many interface opportunities for integrating motorised companions. There are diverse medical reasons, as well as arguments from animal ethics, that support the use of pet robots in contrast to living with live animals. However, as this paper makes clear, we should not lose sight of the option of living with animals at home for as long as possible and in conformity with the welfare of the animal assisted by AAL technology. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  9. Small animal radiotherapy research platforms

    Energy Technology Data Exchange (ETDEWEB)

    Verhaegen, Frank; Granton, Patrick [Department of Radiation Oncology (MAASTRO), GROW-School for Oncology and Developmental Biology, Maastricht University Medical Center, Maastricht 6201 BN (Netherlands); Tryggestad, Erik, E-mail: frank.verhaegen@maastro.nl [Department of Radiation Oncology and Molecular Radiation Sciences, The Johns Hopkins University School of Medicine, Baltimore, MD 21231 (United States)

    2011-06-21

    Advances in conformal radiation therapy and advancements in pre-clinical radiotherapy research have recently stimulated the development of precise micro-irradiators for small animals such as mice and rats. These devices are often kilovolt x-ray radiation sources combined with high-resolution CT imaging equipment for image guidance, as the latter allows precise and accurate beam positioning. This is similar to modern human radiotherapy practice. These devices are considered a major step forward compared to the current standard of animal experimentation in cancer radiobiology research. The availability of this novel equipment enables a wide variety of pre-clinical experiments on the synergy of radiation with other therapies, complex radiation schemes, sub-target boost studies, hypofractionated radiotherapy, contrast-enhanced radiotherapy and studies of relative biological effectiveness, to name just a few examples. In this review we discuss the required irradiation and imaging capabilities of small animal radiation research platforms. We describe the need for improved small animal radiotherapy research and highlight pioneering efforts, some of which led recently to commercially available prototypes. From this, it will be clear that much further development is still needed, on both the irradiation side and imaging side. We discuss at length the need for improved treatment planning tools for small animal platforms, and the current lack of a standard therein. Finally, we mention some recent experimental work using the early animal radiation research platforms, and the potential they offer for advancing radiobiology research. (topical review)

  10. Small animal radiotherapy research platforms

    Science.gov (United States)

    Verhaegen, Frank; Granton, Patrick; Tryggestad, Erik

    2011-06-01

    Advances in conformal radiation therapy and advancements in pre-clinical radiotherapy research have recently stimulated the development of precise micro-irradiators for small animals such as mice and rats. These devices are often kilovolt x-ray radiation sources combined with high-resolution CT imaging equipment for image guidance, as the latter allows precise and accurate beam positioning. This is similar to modern human radiotherapy practice. These devices are considered a major step forward compared to the current standard of animal experimentation in cancer radiobiology research. The availability of this novel equipment enables a wide variety of pre-clinical experiments on the synergy of radiation with other therapies, complex radiation schemes, sub-target boost studies, hypofractionated radiotherapy, contrast-enhanced radiotherapy and studies of relative biological effectiveness, to name just a few examples. In this review we discuss the required irradiation and imaging capabilities of small animal radiation research platforms. We describe the need for improved small animal radiotherapy research and highlight pioneering efforts, some of which led recently to commercially available prototypes. From this, it will be clear that much further development is still needed, on both the irradiation side and imaging side. We discuss at length the need for improved treatment planning tools for small animal platforms, and the current lack of a standard therein. Finally, we mention some recent experimental work using the early animal radiation research platforms, and the potential they offer for advancing radiobiology research.

  11. Small animal radiotherapy research platforms

    International Nuclear Information System (INIS)

    Verhaegen, Frank; Granton, Patrick; Tryggestad, Erik

    2011-01-01

    Advances in conformal radiation therapy and advancements in pre-clinical radiotherapy research have recently stimulated the development of precise micro-irradiators for small animals such as mice and rats. These devices are often kilovolt x-ray radiation sources combined with high-resolution CT imaging equipment for image guidance, as the latter allows precise and accurate beam positioning. This is similar to modern human radiotherapy practice. These devices are considered a major step forward compared to the current standard of animal experimentation in cancer radiobiology research. The availability of this novel equipment enables a wide variety of pre-clinical experiments on the synergy of radiation with other therapies, complex radiation schemes, sub-target boost studies, hypofractionated radiotherapy, contrast-enhanced radiotherapy and studies of relative biological effectiveness, to name just a few examples. In this review we discuss the required irradiation and imaging capabilities of small animal radiation research platforms. We describe the need for improved small animal radiotherapy research and highlight pioneering efforts, some of which led recently to commercially available prototypes. From this, it will be clear that much further development is still needed, on both the irradiation side and imaging side. We discuss at length the need for improved treatment planning tools for small animal platforms, and the current lack of a standard therein. Finally, we mention some recent experimental work using the early animal radiation research platforms, and the potential they offer for advancing radiobiology research. (topical review)

  12. Blended learning in the small animal clinic

    DEFF Research Database (Denmark)

    Langebæk, Rikke

    2011-01-01

    At the Department of Small Animal Clinical Sciences, Basic Surgical Skills are taught in groups of 30-35 students in the first year of the master program (4th year students). The eight day course is an example of ‘blended learning’ in which students use our e-learning-material (Step 1) to prepare...... for the practical part of the course (Step 2, 3 and 4). From their home computers, students log on to the e-learning platform of Copenhagen University: https://absalon.ku.dk and go to the Basic Surgical Skills course, which consist of a line of chapters concerning a variety of surgical subjects. Each subject...... the implementation of these new teaching methods (e-learning and Skills Lab), teachers have ascertained a more satisfactory level of preparation, students that seem more focused and live-animal surgery that is conducted at a more ‘professional’ level than before. Finally, our research in this field shows...

  13. DYNAMICS AND ROMANIA´S PARTNERS IN TRADE OF LIVE ANIMALS

    Directory of Open Access Journals (Sweden)

    Ionela Mituko VLAD

    2014-04-01

    Full Text Available The paper was focused on the sector of trade and meat consumption in Romania. Data are presented at national level and covers a period of 10 years; they come from the Ministry of Agriculture and the National Institute of Statistics of Romania. We presented an analysis of the trade in live animals, according to Romania's main trading partners, the dynamics of household consumption of three types of meat and we present a detailed analysis of the three most important sectors in the trade with live animals. The methodology has also included the study of seasonality of total import and export of live animals and separate of Live cattle trade sector. The findings were that, although the trade in live animals in Romania shows a positive balance, looked in detail, the sector has a significant imbalance between the different categories of animals. So, we could appreciate the fact that the positive balance of the entire trade in live animals is, in fact, supported only by exports of cattle, the other directions having a slight contribution. In terms of seasonality, we identified for imports, positive seasonal deviations in the 2nd quarter and for exports in the 3rd and the 4th quarter.

  14. Fundamental image quality limits for microcomputed tomography in small animals

    International Nuclear Information System (INIS)

    Ford, N.L.; Thornton, M.M.; Holdsworth, D.W.

    2003-01-01

    Small-animal imaging has become increasingly more important as transgenic and knockout mice are produced to model human diseases. One imaging technique that has emerged is microcomputed tomography (micro-CT). For live-animal imaging, the precision in the images will be determined by the x-ray dose given to the animal. As a result, we propose a simple method to predict the noise performance of an x-ray micro-CT system as a function of dose and image resolution. An ideal, quantum-noise limited micro-CT scanner, assumed to have perfect resolution and ideal efficiency, was modeled. Using a simplified model, the coefficient of variation (COV) of the linear attenuation coefficient was calculated for a range of entrance doses and isotropic voxel sizes. COV calculations were performed for the ideal case and with simulated imperfections in efficiency and resolution. Our model was validated in phantom studies and mouse images were acquired with a specimen scanner to illustrate the results. A simplified model of noise propagation in the case of isotropic resolution indicates that the COV in the linear attenuation coefficient is proportional to (dose) -1/2 and to the (isotropic voxel size) -2 in the reconstructed volume. Therefore an improvement in the precision can be achieved only by increasing the isotropic voxel size (thereby decreasing the resolution of the image) or by increasing the x-ray dose. For the ideal scanner, a COV of 1% in the linear attenuation coefficient for an image of a mouse exposed to 0.25 Gy is obtained with a minimum isotropic voxel size of 135 μm. However, the same COV is achieved at a dose of 5.0 Gy with a 65 μm isotropic voxel size. Conversely, for a 68 mm diameter rat, a COV of 1% obtained from an image at 5.0 Gy would require an isotropic voxel size of 100 μm. These results indicate that short-term, potentially lethal, effects of ionizing radiation will limit high-resolution live animal imaging. As improvements in detector technology allow the

  15. Small animal imaging. Basics and practical guide

    Energy Technology Data Exchange (ETDEWEB)

    Kiessling, Fabian [Aachen Univ. (RWTH) (Germany). Chair of Experimental Molecular Imaging; Pichler, Bernd J. (eds.) [Tuebingen Univ. (Germany). Lab. for Preclinical Imaging and Imaging Technology of the Werner Siemens-Foundation

    2011-07-01

    Small animal imaging has been recognized as an important tool in preclinical research. Nevertheless, the results of non-invasive imaging are often disappointing owing to choice of a suboptimal imaging modality and/or shortcomings in study design, experimental setup, and data evaluation. This textbook is a practical guide to the use of non-invasive imaging in preclinical research. Each of the available imaging modalities is discussed in detail, with the assistance of numerous informative illustrations. In addition, many useful hints are provided on the installation of a small animal unit, study planning, animal handling, and the cost-effective performance of small animal imaging. Cross-calibration methods, data postprocessing, and special imaging applications are also considered in depth. This is the first book to cover all the practical basics in small animal imaging, and it will prove an invaluable aid for researchers, students, and technicians. (orig.)

  16. Small animal imaging. Basics and practical guide

    International Nuclear Information System (INIS)

    Kiessling, Fabian; Pichler, Bernd J.

    2011-01-01

    Small animal imaging has been recognized as an important tool in preclinical research. Nevertheless, the results of non-invasive imaging are often disappointing owing to choice of a suboptimal imaging modality and/or shortcomings in study design, experimental setup, and data evaluation. This textbook is a practical guide to the use of non-invasive imaging in preclinical research. Each of the available imaging modalities is discussed in detail, with the assistance of numerous informative illustrations. In addition, many useful hints are provided on the installation of a small animal unit, study planning, animal handling, and the cost-effective performance of small animal imaging. Cross-calibration methods, data postprocessing, and special imaging applications are also considered in depth. This is the first book to cover all the practical basics in small animal imaging, and it will prove an invaluable aid for researchers, students, and technicians. (orig.)

  17. 78 FR 24132 - New Mailing Standards for Live Animals and Special Handling

    Science.gov (United States)

    2013-04-24

    ... POSTAL SERVICE 39 CFR Part 111 New Mailing Standards for Live Animals and Special Handling AGENCY... require special handling service for shipments containing certain types of live animals, to limit the mail classes available for use when shipping certain types of live animals, and to expand the mailability of...

  18. Verification of photon attenuation characteristics for 3D printer based small animal lung model

    International Nuclear Information System (INIS)

    Lee, Se Ho; Lee, Seung Wook; Han, Su Chul; Park, Seung Woo

    2016-01-01

    Since it is difficult to measure absorbed dose to mice in vivo, replica mice are mostly used as alternative. In this study, realistic mouse phantom was fabricated by using 3D printer (object500 connex3, Stratasys, USA). Elemental inks as material of 3D printer were selected corresponding to mouse tissue. To represent lung, selected material was partially used with air layer. In order to verify material equivalent, super-flex bolus was simply compared to verify photon attenuation characteristics. In the case of lung, Hounsfield unit (HU) of the phantom were compared with a live mouse. In this study, we fabricated mouse phantom by using 3D printer, and practically verified photon attenuation characteristics. The fabricated phantom shows tissue equivalence as well as similar geometry with live mouse. As more and more growing of 3D printer technique, 3D printer based small preclinical animal phantom would increase reliability of verification of absorbed dose in small animal for preclinical study

  19. Verification of photon attenuation characteristics for 3D printer based small animal lung model

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Se Ho; Lee, Seung Wook [Pusan National University, Busan (Korea, Republic of); Han, Su Chul; Park, Seung Woo [Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of)

    2016-05-15

    Since it is difficult to measure absorbed dose to mice in vivo, replica mice are mostly used as alternative. In this study, realistic mouse phantom was fabricated by using 3D printer (object500 connex3, Stratasys, USA). Elemental inks as material of 3D printer were selected corresponding to mouse tissue. To represent lung, selected material was partially used with air layer. In order to verify material equivalent, super-flex bolus was simply compared to verify photon attenuation characteristics. In the case of lung, Hounsfield unit (HU) of the phantom were compared with a live mouse. In this study, we fabricated mouse phantom by using 3D printer, and practically verified photon attenuation characteristics. The fabricated phantom shows tissue equivalence as well as similar geometry with live mouse. As more and more growing of 3D printer technique, 3D printer based small preclinical animal phantom would increase reliability of verification of absorbed dose in small animal for preclinical study.

  20. Young Children's Interest in Live Animals

    Science.gov (United States)

    LoBue, Vanessa; Bloom Pickard, Megan; Sherman, Kathleen; Axford, Chrystal; DeLoache, Judy S.

    2013-01-01

    Animals are important stimuli for humans, and for children in particular. In three experiments, we explored children's affinity for animals. In Experiment 1, 11- to 40-month-old children were presented with a free-play session in which they were encouraged to interact with several interesting toys and two live animals--a fish and a hamster.…

  1. High-resolution SPECT for small-animal imaging

    International Nuclear Information System (INIS)

    Qi Yujin

    2006-01-01

    This article presents a brief overview of the development of high-resolution SPECT for small-animal imaging. A pinhole collimator has been used for high-resolution animal SPECT to provide better spatial resolution and detection efficiency in comparison with a parallel-hole collimator. The theory of imaging characteristics of the pinhole collimator is presented and the designs of the pinhole aperture are discussed. The detector technologies used for the development of small-animal SPECT and the recent advances are presented. The evolving trend of small-animal SPECT is toward a multi-pinhole and a multi-detector system to obtain a high resolution and also a high detection efficiency. (authors)

  2. Measurement of flow velocity fields in small vessel-mimic phantoms and vessels of small animals using micro ultrasonic particle image velocimetry (micro-EPIV).

    Science.gov (United States)

    Qian, Ming; Niu, Lili; Wang, Yanping; Jiang, Bo; Jin, Qiaofeng; Jiang, Chunxiang; Zheng, Hairong

    2010-10-21

    Determining a multidimensional velocity field within microscale opaque fluid flows is needed in areas such as microfluidic devices, biofluid mechanics and hemodynamics research in animal studies. The ultrasonic particle image velocimetry (EchoPIV) technique is appropriate for measuring opaque flows by taking advantage of PIV and B-mode ultrasound contrast imaging. However, the use of clinical ultrasound systems for imaging flows in small structures or animals has limitations associated with spatial resolution. This paper reports on the development of a high-resolution EchoPIV technique (termed as micro-EPIV) and its application in measuring flows in small vessel-mimic phantoms and vessels of small animals. Phantom experiments demonstrate the validity of the technique, providing velocity estimates within 4.1% of the analytically derived values with regard to the flows in a small straight vessel-mimic phantom, and velocity estimates within 5.9% of the computationally simulated values with regard to the flows in a small stenotic vessel-mimic phantom. Animal studies concerning arterial and venous flows of living rats and rabbits show that the micro-EPIV-measured peak velocities within several cardiac cycles are about 25% below the values measured by the ultrasonic spectral Doppler technique. The micro-EPIV technique is able to effectively measure the flow fields within microscale opaque fluid flows.

  3. Measurement of flow velocity fields in small vessel-mimic phantoms and vessels of small animals using micro ultrasonic particle image velocimetry (micro-EPIV)

    International Nuclear Information System (INIS)

    Qian Ming; Niu Lili; Jiang Bo; Jin Qiaofeng; Jiang Chunxiang; Zheng Hairong; Wang Yanping

    2010-01-01

    Determining a multidimensional velocity field within microscale opaque fluid flows is needed in areas such as microfluidic devices, biofluid mechanics and hemodynamics research in animal studies. The ultrasonic particle image velocimetry (EchoPIV) technique is appropriate for measuring opaque flows by taking advantage of PIV and B-mode ultrasound contrast imaging. However, the use of clinical ultrasound systems for imaging flows in small structures or animals has limitations associated with spatial resolution. This paper reports on the development of a high-resolution EchoPIV technique (termed as micro-EPIV) and its application in measuring flows in small vessel-mimic phantoms and vessels of small animals. Phantom experiments demonstrate the validity of the technique, providing velocity estimates within 4.1% of the analytically derived values with regard to the flows in a small straight vessel-mimic phantom, and velocity estimates within 5.9% of the computationally simulated values with regard to the flows in a small stenotic vessel-mimic phantom. Animal studies concerning arterial and venous flows of living rats and rabbits show that the micro-EPIV-measured peak velocities within several cardiac cycles are about 25% below the values measured by the ultrasonic spectral Doppler technique. The micro-EPIV technique is able to effectively measure the flow fields within microscale opaque fluid flows.

  4. Trichinella spp. imported with live animals and meat.

    Science.gov (United States)

    Pozio, Edoardo

    2015-09-30

    Nematodes of the genus Trichinella are widely distributed throughout the world in omnivorous and carnivorous animals (mammals, birds, and reptiles) and in incidental hosts. To prevent the transmission of these zoonotic parasites to humans, meat samples from Trichinella spp. susceptible animals are tested at the slaughterhouse or in game processing plants. The aim of the present review was to collect documented cases on Trichinella infected animals, meat, or meat derived products which reached the international trade or were illegally introduced from one to another country in personal baggage. In the course of the last 60 years in the international literature, there have been 43 reports of importation of Trichinella spp. infected animals or meat, most of which (60%, 26/43) related to live horses or their meat. Meat or meat derived products from pigs, wild boar and bears, account only for 18.6% (8/43), 4.7% (3/43), and 14.3% (6/43), respectively. However, only live horses or their meat intended for human consumption, meat from a single wild boar, and live polar bears caught in the wild for zoos, were imported through the international market; whereas, meat from pigs, wild boars and bears were illegally introduced in a country in personal baggage. Trichinella infected animals or meat which were officially or illegally introduced in a country were the source of 3443 Trichinella infections in humans in a 40-year period (1975-2014). Most of these infections (96.8%) have been linked to horsemeat consumption, whereas meat from pigs, wild boars and bears accounted only for 2.2%, 0.7% and 0.3% of cases, respectively. This review shows the Trichinella spp. risk in the international animal and meat trade has been linked mainly to horses and only one time to wild boar, if they carcasses are not adequately tested, whereas pigs and other wild animals or their derived products infected with Trichinella spp. are unlikely to reach the international market by the official animal and

  5. THE ROMANIAN EXTERNAL TRADE IN LIVE ANIMALS AND ANIMAL PRODUCTS

    Directory of Open Access Journals (Sweden)

    Ionela MiĠuko VLAD

    2012-01-01

    Full Text Available In terms of foreign trade, in Romania there were some major changes over the past 20 years. In this paper we have focused on the Romanian external trade. The products which have been taken into account were live animals and animal products. Thus, we have made an analyse on the Romanian imports and exports at the global level and at the European level. Focused on the animal products, on the global level, there were registered major differences during the first seven years in the analysed period. Breaking by branches, we have pointed out huge distinctions between imports and exports, where the balance of trade was completely negative. Meanwhile, to have a good view on the international trade there were made links, based on some indexes between imports, exports, GDP and investments.

  6. Advanced Small Animal Conformal Radiation Therapy Device.

    Science.gov (United States)

    Sharma, Sunil; Narayanasamy, Ganesh; Przybyla, Beata; Webber, Jessica; Boerma, Marjan; Clarkson, Richard; Moros, Eduardo G; Corry, Peter M; Griffin, Robert J

    2017-02-01

    We have developed a small animal conformal radiation therapy device that provides a degree of geometrical/anatomical targeting comparable to what is achievable in a commercial animal irradiator. small animal conformal radiation therapy device is capable of producing precise and accurate conformal delivery of radiation to target as well as for imaging small animals. The small animal conformal radiation therapy device uses an X-ray tube, a robotic animal position system, and a digital imager. The system is in a steel enclosure with adequate lead shielding following National Council on Radiation Protection and Measurements 49 guidelines and verified with Geiger-Mueller survey meter. The X-ray source is calibrated following AAPM TG-61 specifications and mounted at 101.6 cm from the floor, which is a primary barrier. The X-ray tube is mounted on a custom-made "gantry" and has a special collimating assembly system that allows field size between 0.5 mm and 20 cm at isocenter. Three-dimensional imaging can be performed to aid target localization using the same X-ray source at custom settings and an in-house reconstruction software. The small animal conformal radiation therapy device thus provides an excellent integrated system to promote translational research in radiation oncology in an academic laboratory. The purpose of this article is to review shielding and dosimetric measurement and highlight a few successful studies that have been performed to date with our system. In addition, an example of new data from an in vivo rat model of breast cancer is presented in which spatially fractionated radiation alone and in combination with thermal ablation was applied and the therapeutic benefit examined.

  7. Thermoacoustic Molecular Imaging of Small Animals

    Directory of Open Access Journals (Sweden)

    Robert A. Kruger

    2003-04-01

    Full Text Available We have designed, constructed, and tested a thermoacoustic computed tomography (TCT scanner for imaging optical absorption in small animals in three dimensions. The device utilizes pulsed laser irradiation (680–1064 nm and a unique, 128-element transducer array. We quantified the isotropic spatial resolution of this scanner to be 0.35 mm. We describe a dual-wavelength subtraction technique for isolating optical dyes with TCT. Phantom experiments demonstrate that we can detect 5 fmol of a near-infrared dye (indocyanine green, ICG in a 1-ML volume using dual-wavelength subtraction. Initial TCT imaging in phantoms and in two sacrificed mice suggests that three-dimensional, optical absorption patterns in small animals can be detected with an order of magnitude better spatial resolution and an order of magnitude better low-contrast detectability in small animals when compared to fluorescence imaging or diffusion optical tomography.

  8. Developments in undergraduate teaching of small-animal soft-tissue surgical skills at the University of Sydney.

    Science.gov (United States)

    Gopinath, Deepa; McGreevy, Paul D; Zuber, Richard M; Klupiec, Corinna; Baguley, John; Barrs, Vanessa R

    2012-01-01

    This article discusses recent developments in soft-tissue surgery teaching at the University of Sydney, Faculty of Veterinary Science. An integrated teaching program was developed for Bachelor of Veterinary Science (BVSc) students with the aim of providing them with optimal learning opportunities to meet "Day One" small-animal soft-tissue surgical competencies. Didactic lectures and tutorials were introduced earlier into the curriculum to prepare students for live-animal surgery practical. In addition to existing clinics, additional spay/neuter clinics were established in collaboration with animal welfare organizations to increase student exposure to live-animal surgery. A silicon-based, life-like canine ovariohysterectomy model was developed with the assistance of a model-making and special effects company. The model features elastic ovarian pedicles and suspensory ligaments, which can be stretched and broken like those of an actual dog. To monitor the volume and type of student surgical experience, an E-portfolio resource was established. This resource allows for the tracking of numbers of live, student-performed desexing surgeries and incorporates competency-based assessments and reflective tasks to be completed by students. Student feedback on the integrated surgical soft-tissue teaching program was assessed. Respondents were assessed in the fourth year of the degree and will have further opportunities to develop Day One small-animal soft-tissue surgical competencies in the fifth year. Ninety-four percent of respondents agreed or strongly agreed that they were motivated to participate in all aspects of the program, while 78% agreed or strongly agreed that they received an adequate opportunity to develop their skills and confidence in ovariohysterectomy or castration procedures through the fourth-year curriculum.

  9. Molecular Imaging with Small Animal PET/CT

    DEFF Research Database (Denmark)

    Binderup, T.; El-Ali, H.H.; Skovgaard, D.

    2011-01-01

    is also described. In addition, the non-invasive nature of molecular imaging and the targets of these promising new tracers are attractive for other research areas as well, although these fields are much less explored. We present an example of an interesting research field with the application of small......Small animal positron emission tomography (PET) and computer tomography (CT) is an emerging field in pre-clinical imaging. High quality, state-of-the-art instruments are required for full optimization of the translational value of the small animal studies with PET and CT. However...... in this field of small animal molecular imaging with special emphasis on the targets for tissue characterization in tumor biology such as hypoxia, proliferation and cancer specific over-expression of receptors. The added value of applying CT imaging for anatomical localization and tumor volume measurements...

  10. SU-E-T-124: Anthropomorphic Phantoms for Confirmation of Linear Accelerator Based Small Animal Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Perks, J; Benedict, S [UC Davis Cancer Center, Sacramento, CA (United States); Lucero, S [UC Davis, Davis, CA (United States)

    2015-06-15

    Purpose: To document the support of radiobiological small animal research by a modern radiation oncology facility. This study confirms that a standard, human use linear accelerator can cover the range of experiments called for by researchers performing animal irradiation. A number of representative, anthropomorphic murine phantoms were made. The phantoms confirmed the small field photon and electron beams dosimetry validated the use of the linear accelerator for rodents. Methods: Laser scanning a model, CAD design and 3D printing produced the phantoms. The phantoms were weighed and CT scanned to judge their compatibility to real animals. Phantoms were produced to specifically mimic lung, gut, brain, and othotopic lesion irradiations. Each phantom was irradiated with the same protocol as prescribed to the live animals. Delivered dose was measured with small field ion chambers, MOS/FETs or TLDs. Results: The density of the phantom material compared to density range across the real mice showed that the printed material would yield sufficiently accurate measurements when irradiated. The whole body, lung and gut irradiations were measured within 2% of prescribed doses with A1SL ion chamber. MOSFET measurements of electron irradiations for the orthotopic lesions allowed refinement of the measured small field output factor to better than 2% and validated the immunology experiment of irradiating one lesion and sparing another. Conclusion: Linacs are still useful tools in small animal bio-radiation research. This work demonstrated a strong role for the clinical accelerator in small animal research, facilitating standard whole body dosing as well as conformal treatments down to 1cm field. The accuracy of measured dose, was always within 5%. The electron irradiations of the phantom brain and flank tumors needed adjustment; the anthropomorphic phantoms allowed refinement of the initial output factor measurements for these fields which were made in a large block of solid water.

  11. Automated high-content live animal drug screening using C. elegans expressing the aggregation prone serpin α1-antitrypsin Z.

    Directory of Open Access Journals (Sweden)

    Sager J Gosai

    2010-11-01

    Full Text Available The development of preclinical models amenable to live animal bioactive compound screening is an attractive approach to discovering effective pharmacological therapies for disorders caused by misfolded and aggregation-prone proteins. In general, however, live animal drug screening is labor and resource intensive, and has been hampered by the lack of robust assay designs and high throughput work-flows. Based on their small size, tissue transparency and ease of cultivation, the use of C. elegans should obviate many of the technical impediments associated with live animal drug screening. Moreover, their genetic tractability and accomplished record for providing insights into the molecular and cellular basis of human disease, should make C. elegans an ideal model system for in vivo drug discovery campaigns. The goal of this study was to determine whether C. elegans could be adapted to high-throughput and high-content drug screening strategies analogous to those developed for cell-based systems. Using transgenic animals expressing fluorescently-tagged proteins, we first developed a high-quality, high-throughput work-flow utilizing an automated fluorescence microscopy platform with integrated image acquisition and data analysis modules to qualitatively assess different biological processes including, growth, tissue development, cell viability and autophagy. We next adapted this technology to conduct a small molecule screen and identified compounds that altered the intracellular accumulation of the human aggregation prone mutant that causes liver disease in α1-antitrypsin deficiency. This study provides powerful validation for advancement in preclinical drug discovery campaigns by screening live C. elegans modeling α1-antitrypsin deficiency and other complex disease phenotypes on high-content imaging platforms.

  12. Novel fusion protein approach for efficient high-throughput screening of small molecule-mediating protein-protein interactions in cells and living animals.

    Science.gov (United States)

    Paulmurugan, Ramasamy; Gambhir, Sanjiv S

    2005-08-15

    Networks of protein interactions execute many different intracellular pathways. Small molecules either synthesized within the cell or obtained from the external environment mediate many of these protein-protein interactions. The study of these small molecule-mediated protein-protein interactions is important in understanding abnormal signal transduction pathways in a variety of disorders, as well as in optimizing the process of drug development and validation. In this study, we evaluated the rapamycin-mediated interaction of the human proteins FK506-binding protein (FKBP12) rapamycin-binding domain (FRB) and FKBP12 by constructing a fusion of these proteins with a split-Renilla luciferase or a split enhanced green fluorescent protein (split-EGFP) such that complementation of the reporter fragments occurs in the presence of rapamycin. Different linker peptides in the fusion protein were evaluated for the efficient maintenance of complemented reporter activity. This system was studied in both cell culture and xenografts in living animals. We found that peptide linkers with two or four EAAAR repeat showed higher protein-protein interaction-mediated signal with lower background signal compared with having no linker or linkers with amino acid sequences GGGGSGGGGS, ACGSLSCGSF, and ACGSLSCGSFACGSLSCGSF. A 9 +/- 2-fold increase in signal intensity both in cell culture and in living mice was seen compared with a system that expresses both reporter fragments and the interacting proteins separately. In this fusion system, rapamycin induced heterodimerization of the FRB and FKBP12 moieties occurred rapidly even at very lower concentrations (0.00001 nmol/L) of rapamycin. For a similar fusion system employing split-EGFP, flow cytometry analysis showed significant level of rapamycin-induced complementation.

  13. Clinical aspects of toxoplasmosis in small animal

    Directory of Open Access Journals (Sweden)

    André Luiz Baptista Galvão

    2014-02-01

    Full Text Available Toxoplasmosis, a zoonosis of worldwide distribution, has importance in human and veterinary medicine. Animals can be direct or indirect source of infection to man, and this intermediate host, the disease may be responsible for encephalitis and deaths due to congenital form as coinfection in neonates and patients with acquired immunodeficiency syndrome. The man and animals can acquire the disease by eating undercooked meat or cures, infected with tissue cysts, as well as food and water contaminated with oocysts. Iatrogenic, such as, blood transfusion and organ transplantation are other less frequent routes of transmission. The causative agent of this disease is Toxoplasma gondii, a protozoan obligate intracellular coccidian. In small animals, the infection has been reported in several countries, promoting varied clinical manifestations and uncommon but severe and fatal, which is a challenge in the clinical diagnosis of small animals, especially when the nervous system involvement. Thus, constitute the purpose of this review address the participation of small animals in the spread of the disease, clinical aspects related to it, as well as discuss methods of diagnosis, therapeutic measures, prophylaxis and control of this disease.

  14. Small Animal Models for Evaluating Filovirus Countermeasures.

    Science.gov (United States)

    Banadyga, Logan; Wong, Gary; Qiu, Xiangguo

    2018-05-11

    The development of novel therapeutics and vaccines to treat or prevent disease caused by filoviruses, such as Ebola and Marburg viruses, depends on the availability of animal models that faithfully recapitulate clinical hallmarks of disease as it is observed in humans. In particular, small animal models (such as mice and guinea pigs) are historically and frequently used for the primary evaluation of antiviral countermeasures, prior to testing in nonhuman primates, which represent the gold-standard filovirus animal model. In the past several years, however, the filovirus field has witnessed the continued refinement of the mouse and guinea pig models of disease, as well as the introduction of the hamster and ferret models. We now have small animal models for most human-pathogenic filoviruses, many of which are susceptible to wild type virus and demonstrate key features of disease, including robust virus replication, coagulopathy, and immune system dysfunction. Although none of these small animal model systems perfectly recapitulates Ebola virus disease or Marburg virus disease on its own, collectively they offer a nearly complete set of tools in which to carry out the preclinical development of novel antiviral drugs.

  15. A Very High Spatial Resolution Detector for Small Animal PET

    International Nuclear Information System (INIS)

    Kanai Shah, M.S.

    2007-01-01

    Positron Emission Tomography (PET) is an in vivo analog of autoradiography and has the potential to become a powerful new tool in imaging biological processes in small laboratory animals. PET imaging of small animals can provide unique information that can help in advancement of human disease models as well as drug development. Clinical PET scanners used for human imaging are bulky, expensive and do not have adequate spatial resolution for small animal studies. Hence, dedicated, low cost instruments are required for conducting small animal studies with higher spatial resolution than what is currently achieved with clinical as well as dedicated small animal PET scanners. The goal of the proposed project is to investigate a new all solid-state detector design for small animal PET imaging. Exceptionally high spatial resolution, good timing resolution, and excellent energy resolution are expected from the proposed detector design. The Phase I project was aimed at demonstrating the feasibility of producing high performance solid-state detectors that provide high sensitivity, spatial resolution, and timing characteristics. Energy resolution characteristics of the new detector were also investigated. The goal of the Phase II project is to advance the promising solid-state detector technology for small animal PET and determine its full potential. Detectors modules will be built and characterized and finally, a bench-top small animal PET system will be assembled and evaluated

  16. Small animal PET: aspects of performance assessment

    International Nuclear Information System (INIS)

    Weber, Simone; Bauer, Andreas

    2004-01-01

    Dedicated small animal positron emission tomography (PET) systems are increasingly prevalent in industry (e.g. for preclinical drug development) and biological research. Such systems permit researchers to perform animal studies of a longitudinal design characterised by repeated measurements in single animals. With the advent of commercial systems, scanners have become readily available and increasingly popular. As a consequence, technical specifications are becoming more diverse, making scanner systems less broadly applicable. The investigator has, therefore, to make a decision regarding which type of scanner is most suitable for the intended experiments. This decision should be based on gantry characteristics and the physical performance. The first few steps have been taken towards standardisation of the assessment of performance characteristics of dedicated animal PET systems, though such assessment is not yet routinely implemented. In this review, we describe current methods of evaluation of physical performance parameters of small animal PET scanners. Effects of methodologically different approaches on the results are assessed. It is underscored that particular attention has to be paid to spatial resolution, sensitivity, scatter fraction and count rate performance. Differences in performance measurement methods are described with regard to commercially available systems, namely the Concorde MicroPET systems P4 and R4 and the quad-HIDAC. Lastly, consequences of differences in scanner performance parameters are rated with respect to applications of small animal PET. (orig.)

  17. Dose evaluation of three-dimensional small animal phantom with film dosimetry

    International Nuclear Information System (INIS)

    Han, Su Chul; Park, Seung Woo

    2017-01-01

    The weight of small animal dosimetry has been continuously increased in pre-clinical studies using radiation in small animals. In this study, three-dimensional(3D) small animal phantom was fabricated using 3D printer which has been continuously used and studied in the various fields. The absorbed dose of 3D animal phantom was evaluated by film dosimetry. Previously, the response of film was obtained from the materials used for production of 3D small animal phantom and compared with the bolus used as the tissue equivalent material in the radiotherapy. When irradiated with gamma rays from 0.5 Gy to 6 Gy, it was confirmed that there was a small difference of less than 1% except 0.5 Gy dose. And when small animal phantom was irradiated with 5 Gy, the difference between the irradiated dose and calculated dose from film was within 2%. Based on this study, it would be possible to increase the reliability of dose in pre-clinical studies using irradiation in small animals by evaluating dose of 3D small animal phantom

  18. Dose evaluation of three-dimensional small animal phantom with film dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Han, Su Chul [Div. of Medical Radiation Equipment, Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of); Park, Seung Woo [Radilogcial and Medico-Oncological Sciences, University of Sciences and Technology, Daejeon (Korea, Republic of)

    2017-03-15

    The weight of small animal dosimetry has been continuously increased in pre-clinical studies using radiation in small animals. In this study, three-dimensional(3D) small animal phantom was fabricated using 3D printer which has been continuously used and studied in the various fields. The absorbed dose of 3D animal phantom was evaluated by film dosimetry. Previously, the response of film was obtained from the materials used for production of 3D small animal phantom and compared with the bolus used as the tissue equivalent material in the radiotherapy. When irradiated with gamma rays from 0.5 Gy to 6 Gy, it was confirmed that there was a small difference of less than 1% except 0.5 Gy dose. And when small animal phantom was irradiated with 5 Gy, the difference between the irradiated dose and calculated dose from film was within 2%. Based on this study, it would be possible to increase the reliability of dose in pre-clinical studies using irradiation in small animals by evaluating dose of 3D small animal phantom.

  19. Denoising of high resolution small animal 3D PET data using the non-subsampled Haar wavelet transform

    International Nuclear Information System (INIS)

    Ochoa Domínguez, Humberto de Jesús; Máynez, Leticia O.; Vergara Villegas, Osslan O.; Mederos, Boris; Mejía, José M.; Cruz Sánchez, Vianey G.

    2015-01-01

    PET allows functional imaging of the living tissue. However, one of the most serious technical problems affecting the reconstructed data is the noise, particularly in images of small animals. In this paper, a method for high-resolution small animal 3D PET data is proposed with the aim to reduce the noise and preserve details. The method is based on the estimation of the non-subsampled Haar wavelet coefficients by using a linear estimator. The procedure is applied to the volumetric images, reconstructed without correction factors (plane reconstruction). Results show that the method preserves the structures and drastically reduces the noise that contaminates the image

  20. Denoising of high resolution small animal 3D PET data using the non-subsampled Haar wavelet transform

    Energy Technology Data Exchange (ETDEWEB)

    Ochoa Domínguez, Humberto de Jesús, E-mail: hochoa@uacj.mx [Departamento de Ingeniería Eléctrica y computación, Universidad Autónoma de Ciudad Juárez, Ciudad Juárez, Chih. (Mexico); Máynez, Leticia O. [Departamento de Ingeniería Eléctrica y computación, Universidad Autónoma de Ciudad Juárez, Ciudad Juárez, Chih. (Mexico); Vergara Villegas, Osslan O. [Departamento de Ingeniería Industrial, Universidad Autónoma de Ciudad Juárez, Ciudad Juárez, Chih. (Mexico); Mederos, Boris; Mejía, José M.; Cruz Sánchez, Vianey G. [Departamento de Ingeniería Eléctrica y computación, Universidad Autónoma de Ciudad Juárez, Ciudad Juárez, Chih. (Mexico)

    2015-06-01

    PET allows functional imaging of the living tissue. However, one of the most serious technical problems affecting the reconstructed data is the noise, particularly in images of small animals. In this paper, a method for high-resolution small animal 3D PET data is proposed with the aim to reduce the noise and preserve details. The method is based on the estimation of the non-subsampled Haar wavelet coefficients by using a linear estimator. The procedure is applied to the volumetric images, reconstructed without correction factors (plane reconstruction). Results show that the method preserves the structures and drastically reduces the noise that contaminates the image.

  1. Near Field UHF RFID Antenna System Enabling the Tracking of Small Laboratory Animals

    Directory of Open Access Journals (Sweden)

    Luca Catarinucci

    2013-01-01

    Full Text Available Radio frequency identification (RFID technology is more and more adopted in a wide range of applicative scenarios. In many cases, such as the tracking of small-size living animals for behaviour analysis purposes, the straightforward use of commercial solutions does not ensure adequate performance. Consequently, both RFID hardware and the control software should be tailored for the particular application. In this work, a novel RFID-based approach enabling an effective localization and tracking of small-sized laboratory animals is proposed. It is mainly based on a UHF Near Field RFID multiantenna system, to be placed under the animals’ cage, and able to rigorously identify the NF RFID tags implanted in laboratory animals (e.g., mice. Once the requirements of the reader antenna have been individuated, the antenna system has been designed and realized. Moreover, an algorithm based on the measured Received Signal Strength Indication (RSSI aiming at removing potential ambiguities in data captured by the multiantenna system has been developed and integrated. The animal tracking system has been largely tested on phantom mice in order to verify its ability to precisely localize each subject and to reconstruct its path. The achieved and discussed results demonstrate the effectiveness of the proposed tracking system.

  2. Small animal PET and its applications in biomedical research

    International Nuclear Information System (INIS)

    Qiu Feichan

    2004-01-01

    Positron emission tomography (PET) is a nuclear medical imaging technique that permits the use of positron-labeled molecular imaging probes for non-invasive assays of biochemical processes. As the leading technology in nuclear medicine, PET has extended its applications from the clinical field to the study of small laboratory animals. In recent years, the development of new detector technology has dramatically improved the spatial resolution and image quality of small animal PET scanner, which is being used increasingly as a basic tool in modern biomedical research. In particular, small animal PET will play an important role in drug discovery and development, in the study of small animal models of human diseases, in characterizing gene expression and in many other ways. (authors)

  3. Live animal and carcass characteristics of South African indigenous ...

    African Journals Online (AJOL)

    The effect of sex, age and pre-slaughter conditioning on live animal, carcass dimensions and carcass composition were evaluated. The goats were large with live weight, carcass weight and carcass dimensions in the range of the large breeds of southern Africa. They had a high lean and low fat content. Intact males were ...

  4. Advances in Small Animal Imaging Systems

    International Nuclear Information System (INIS)

    Loudos, George K.

    2007-01-01

    The rapid growth in genetics and molecular biology combined with the development of techniques for genetically engineering small animals has led to an increased interest in in vivo laboratory animal imaging during the past few years. For this purpose, new instrumentation, data acquisition strategies, and image processing and reconstruction techniques are being developed, researched and evaluated. The aim of this article is to give a short overview of the state of the art technologies for high resolution and high sensitivity molecular imaging techniques, primarily positron emission tomography (PET) and single photon emission computed tomography (SPECT). The basic needs of small animal imaging will be described. The evolution in instrumentation in the past two decades, as well as the commercially available systems will be overviewed. Finally, the new trends in detector technology and preliminary results from challenging applications will be presented. For more details a number of references are provided

  5. Grief and Bereavement Issues and the Loss of a Companion Animal: People Living with a Companion Animal, Owners of Livestock, and Animal Support Workers

    Science.gov (United States)

    Chur-Hansen, Anna

    2010-01-01

    Companion animals play various roles in people's lives and these roles can impact on loss, grief, bereavement and mourning when the animal has been lost, whether that is through death, when missing, or when relinquished. This paper considers not only companion animal owners, but also those who own farm animals and those who work in animal service…

  6. Review of Russian language studies on radionuclide behaviour in agricultural animals: biological half-lives

    International Nuclear Information System (INIS)

    Fesenko, S.; Isamov, N.; Barnett, C.L.; Beresford, N.A.; Howard, B.J.; Sanzharova, N.; Fesenko, E.

    2015-01-01

    Extensive studies on transfer of radionuclides to animals were carried out in the USSR from the 1950s. Few of these studies were published in the international refereed literature or taken into account in international reviews. This paper continues a series of reviews of Russian language literature on radionuclide transfer to animals, providing information on biological half-lives of radionuclides in various animal tissues. The data are compared, where possible, with those reported in other countries. The data are normally quantified using a single or double exponential accounting for different proportions of the loss. For some products, such as milk, biological half-lives tend to be rapid at 1–3 d for most radionuclides and largely described by a single exponential. However, for other animal products biological half-lives can vary widely as they are influenced by many factors such as the age and size of the animal. Experimental protocols, such as the duration of the study, radionuclide administration and/or sample collection protocol also influence the value of biological half-lives estimated. - Highlights: • The data on biological half-lives from Russian language literature were reviewed. • Radionuclides with the shortest half-lives in animals are those which accumulate in soft tissues. • Short term behaviour is affected by the form in which radionuclides are administered. • There is a tendency for more rapid radionuclide turnover in younger animals

  7. Intrinsic respiratory gating in small-animal CT

    International Nuclear Information System (INIS)

    Bartling, Soenke H.; Dinkel, Julien; Kauczor, Hans-Ulrich; Stiller, Wolfram; Semmler, Wolfhard; Grasruck, Michael; Madisch, Ijad; Gupta, Rajiv; Kiessling, Fabian

    2008-01-01

    Gating in small-animal CT imaging can compensate artefacts caused by physiological motion during scanning. However, all published gating approaches for small animals rely on additional hardware to derive the gating signals. In contrast, in this study a novel method of intrinsic respiratory gating of rodents was developed and tested for mice (n=5), rats (n=5) and rabbits (n=2) in a flat-panel cone-beam CT system. In a consensus read image quality was compared with that of non-gated and retrospective extrinsically gated scans performed using a pneumatic cushion. In comparison to non-gated images, image quality improved significantly using intrinsic and extrinsic gating. Delineation of diaphragm and lung structure improved in all animals. Image quality of intrinsically gated CT was judged to be equivalent to extrinsically gated ones. Additionally 4D datasets were calculated using both gating methods. Values for expiratory, inspiratory and tidal lung volumes determined with the two gating methods were comparable and correlated well with values known from the literature. We could show that intrinsic respiratory gating in rodents makes additional gating hardware and preparatory efforts superfluous. This method improves image quality and allows derivation of functional data. Therefore it bears the potential to find wide applications in small-animal CT imaging. (orig.)

  8. Prevalence and pattern of small animal orthopaedic conditions at ...

    African Journals Online (AJOL)

    Small animal orthopaedic case records of a 20-year period were surveyed to obtain the prevalence and pattern of orthopaedic conditions presented to the Veterinary Teaching Hospital (VTH), University of Ibadan, Nigeria, with the objective of providing data for planning on small animal healthcare facilities, policy ...

  9. Frequency domain fluorescence diffuse tomography of small animals

    Science.gov (United States)

    Orlova, Anna G.; Turchin, Ilya V.; Kamensky, Vladislav A.; Plehanov, Vladimir I.; Balalaeva, Irina V.; Sergeeva, Ekaterina A.; Shirmanova, Marina V.; Kleshnin, Michail S.

    2007-05-01

    Fluorescent compounds for selective cancer cell marking are used for development of novel medical diagnostic methods, investigation of the influence of external factors on tumor growth, regress and metastasis. Only special tools for turbid media imaging, such as optical diffusion tomography permit noninvasive monitoring of fluorescent-labeled tumor alterations deep in animal tissue. In this work, the results of preliminary experiments utilizing frequency-domain fluorescent diffusion tomography (FD FDT) experimental setup in small animal are presented. Low-frequency modulated light (1 kHz) from Nd:YAG laser with second harmonic generation at the wavelength of 532 nm was used in the setup. The transilluminative planar configuration was used in the setup. A series of model experiments has been conducted and show good agreement between theoretical and experimental fluorescence intensity. Models of deep tumors were created by two methods: (1) glass capsules containing fluorophore solution were inserted into esophagus of small animals to simulate marked tumors; (2) a suspension of transfected HEΚ293-Turbo-RFP cells was subcutaneously injected to small animal. The conducted experiments have shown that FD FDT allows one to detect the presence of labeled tumor cells in small animals, to determine the volume of an experimental tumor, to perform 3D tumor reconstruction, as well as to conduct monitoring investigations. The obtained results demonstrate the potential capability of the FD FDT method for noninvasive whole-body imaging in cancer studies, diagnostics and therapy.

  10. Review of Russian language studies on radionuclide behaviour in agricultural animals: biological half-lives.

    Science.gov (United States)

    Fesenko, S; Isamov, N; Barnett, C L; Beresford, N A; Howard, B J; Sanzharova, N; Fesenko, E

    2015-04-01

    Extensive studies on transfer of radionuclides to animals were carried out in the USSR from the 1950s. Few of these studies were published in the international refereed literature or taken into account in international reviews. This paper continues a series of reviews of Russian language literature on radionuclide transfer to animals, providing information on biological half-lives of radionuclides in various animal tissues. The data are compared, where possible, with those reported in other countries. The data are normally quantified using a single or double exponential accounting for different proportions of the loss. For some products, such as milk, biological half-lives tend to be rapid at 1-3 d for most radionuclides and largely described by a single exponential. However, for other animal products biological half-lives can vary widely as they are influenced by many factors such as the age and size of the animal. Experimental protocols, such as the duration of the study, radionuclide administration and/or sample collection protocol also influence the value of biological half-lives estimated. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Sensing of Vascular Permeability in Inflamed Vessel of Live Animal

    Directory of Open Access Journals (Sweden)

    Sang A Park

    2018-01-01

    Full Text Available Increase in vascular permeability is a conclusive response in the progress of inflammation. Under controlled conditions, leukocytes are known to migrate across the vascular barriers to the sites of inflammation without severe vascular rupture. However, when inflammatory state becomes excessive, the leakage of blood components may occur and can be lethal. Basically, vascular permeability can be analyzed based on the intensity of blood outflow. To evaluate the amount and rate of leakage in live mice, we performed cremaster muscle exteriorization to visualize blood flow and neutrophil migration. Using two-photon intravital microscopy of the exteriorized cremaster muscle venules, we found that vascular barrier function is transiently and locally disrupted in the early stage of inflammatory condition induced by N-formylmethionyl-leucyl-phenylalanine (fMLP. Measurement of the concentration of intravenously (i.v. injected Texas Red dextran inside and outside the vessels resulted in clear visualization of real-time increases in transient and local vascular permeability increase in real-time manner. We successfully demonstrated repeated leakage from a target site on a blood vessel in association with increasing severity of inflammation. Therefore, compared to other methods, two-photon intravital microscopy more accurately visualizes and quantifies vascular permeability even in a small part of blood vessels in live animals in real time.

  12. Semiautomated analysis of small-animal PET data.

    Science.gov (United States)

    Kesner, Adam L; Dahlbom, Magnus; Huang, Sung-Cheng; Hsueh, Wei-Ann; Pio, Betty S; Czernin, Johannes; Kreissl, Michael; Wu, Hsiao-Ming; Silverman, Daniel H S

    2006-07-01

    The objective of the work reported here was to develop and test automated methods to calculate biodistribution of PET tracers using small-animal PET images. After developing software that uses visually distinguishable organs and other landmarks on a scan to semiautomatically coregister a digital mouse phantom with a small-animal PET scan, we elastically transformed the phantom to conform to those landmarks in 9 simulated scans and in 18 actual PET scans acquired of 9 mice. Tracer concentrations were automatically calculated in 22 regions of interest (ROIs) reflecting the whole body and 21 individual organs. To assess the accuracy of this approach, we compared the software-measured activities in the ROIs of simulated PET scans with the known activities, and we compared the software-measured activities in the ROIs of real PET scans both with manually established ROI activities in original scan data and with actual radioactivity content in immediately harvested tissues of imaged animals. PET/atlas coregistrations were successfully generated with minimal end-user input, allowing rapid quantification of 22 separate tissue ROIs. The simulated scan analysis found the method to be robust with respect to the overall size and shape of individual animal scans, with average activity values for all organs tested falling within the range of 98% +/- 3% of the organ activity measured in the unstretched phantom scan. Standardized uptake values (SUVs) measured from actual PET scans using this semiautomated method correlated reasonably well with radioactivity content measured in harvested organs (median r = 0.94) and compared favorably with conventional SUV correlations with harvested organ data (median r = 0.825). A semiautomated analytic approach involving coregistration of scan-derived images with atlas-type images can be used in small-animal whole-body radiotracer studies to estimate radioactivity concentrations in organs. This approach is rapid and less labor intensive than are

  13. State-of-the-art of small animal imaging with high-resolution SPECT

    International Nuclear Information System (INIS)

    Nikolaus, S.; Wirrwar, A.; Antke, C.; Kley, K.; Mueller, H.W.

    2005-01-01

    During the recent years, in vivo imaging of small animals using SPECT has become of growing relevance. Along with the development of dedicated high-resolution small animal SPECT cameras, an increasing number of conventional clinical scanners has been equipped with single or multipinhole collimators. This paper reviews the small animal tomographs, which are operating at present and compares their performance characteristics. Furthermore, we describe the in vivo imaging studies, which have been performed so far with the individual scanners and survey current approaches to optimize molecular imaging with small animal SPECT. (orig.)

  14. Molecular imaging of small animals with dedicated PET tomographs

    International Nuclear Information System (INIS)

    Chatziioannou, A.F.

    2002-01-01

    Biological discovery has moved at an accelerated pace in recent years, with a considerable focus on the transition from in vitro to in vivo models. As a result, there has been a significant increase in the need to adapt clinical imaging methods, as well as for novel imaging technologies for biological research. Positron emission tomography (PET) is a clinical imaging modality that permits the use of positron-labeled molecular imaging probes for non-invasive assays of biochemical processes. The imaging procedure can be repeatedly performed before and after interventions, thereby allowing each animal to be used as its own control. Positron-labeled compounds that target a range of molecular targets have been and continue to be synthesized, with examples of biological processes ranging from receptors and synthesis of transmitters in cell communication, to metabolic processes and gene expression. In animal research, PET has been used extensively in the past for studies of non-human primates and other larger animals. New detector technology has improved spatial resolution, and has made possible PET scanning for the study of the most important modern molecular biology model, the laboratory mouse. This paper presents the challenges facing PET technology as applied to small animal imaging, provides a historical overview of the development of small animal PET systems, and discusses the current state of the art in small animal PET technology. (orig.)

  15. Theoretical considerations on maximum running speeds for large and small animals.

    Science.gov (United States)

    Fuentes, Mauricio A

    2016-02-07

    Mechanical equations for fast running speeds are presented and analyzed. One of the equations and its associated model predict that animals tend to experience larger mechanical stresses in their limbs (muscles, tendons and bones) as a result of larger stride lengths, suggesting a structural restriction entailing the existence of an absolute maximum possible stride length. The consequence for big animals is that an increasingly larger body mass implies decreasing maximal speeds, given that the stride frequency generally decreases for increasingly larger animals. Another restriction, acting on small animals, is discussed only in preliminary terms, but it seems safe to assume from previous studies that for a given range of body masses of small animals, those which are bigger are faster. The difference between speed scaling trends for large and small animals implies the existence of a range of intermediate body masses corresponding to the fastest animals. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Implementation and assessment of an animal management system for small-animal micro-CT / micro-SPECT imaging

    Science.gov (United States)

    Holdsworth, David W.; Detombe, Sarah A.; Chiodo, Chris; Fricke, Stanley T.; Drangova, Maria

    2011-03-01

    Advances in laboratory imaging systems for CT, SPECT, MRI, and PET facilitate routine micro-imaging during pre-clinical investigations. Challenges still arise when dealing with immune-compromised animals, biohazardous agents, and multi-modality imaging. These challenges can be overcome with an appropriate animal management system (AMS), with the capability for supporting and monitoring a rat or mouse during micro-imaging. We report the implementation and assessment of a new AMS system for mice (PRA-3000 / AHS-2750, ASI Instruments, Warren MI), designed to be compatible with a commercial micro-CT / micro-SPECT imaging system (eXplore speCZT, GE Healthcare, London ON). The AMS was assessed under the following criteria: 1) compatibility with the imaging system (i.e. artifact generation, geometric dimensions); 2) compatibility with live animals (i.e. positioning, temperature regulation, anesthetic supply); 3) monitoring capabilities (i.e. rectal temperature, respiratory and cardiac monitoring); 4) stability of co-registration; and 5) containment. Micro-CT scans performed using a standardized live-animal protocol (90 kVp, 40 mA, 900 views, 16 ms per view) exhibited low noise (+/-19 HU) and acceptable artifact from high-density components within the AMS (e.g. ECG pad contacts). Live mice were imaged repeatedly (with removal and replacement of the AMS) and spatial registration was found to be stable to within +/-0.07 mm. All animals tolerated enclosure within the AMS for extended periods (i.e. > one hour) without distress, based on continuous recordings of rectal temperature, ECG waveform and respiratory rate. A sealed AMS system extends the capability of a conventional micro-imaging system to include immune-compromised and biosafety level 2 mouse-imaging protocols.

  17. Treatment planning for a small animal using Monte Carlo simulation

    International Nuclear Information System (INIS)

    Chow, James C. L.; Leung, Michael K. K.

    2007-01-01

    The development of a small animal model for radiotherapy research requires a complete setup of customized imaging equipment, irradiators, and planning software that matches the sizes of the subjects. The purpose of this study is to develop and demonstrate the use of a flexible in-house research environment for treatment planning on small animals. The software package, called DOSCTP, provides a user-friendly platform for DICOM computed tomography-based Monte Carlo dose calculation using the EGSnrcMP-based DOSXYZnrc code. Validation of the treatment planning was performed by comparing the dose distributions for simple photon beam geometries calculated through the Pinnacle3 treatment planning system and measurements. A treatment plan for a mouse based on a CT image set by a 360-deg photon arc is demonstrated. It is shown that it is possible to create 3D conformal treatment plans for small animals with consideration of inhomogeneities using small photon beam field sizes in the diameter range of 0.5-5 cm, with conformal dose covering the target volume while sparing the surrounding critical tissue. It is also found that Monte Carlo simulation is suitable to carry out treatment planning dose calculation for small animal anatomy with voxel size about one order of magnitude smaller than that of the human

  18. Advances in endoscopic surgery for small animal reproduction.

    Science.gov (United States)

    Katic, N; Dupré, G

    2016-09-01

    Although endoscopic surgery entered its "golden era" in the mid-1980s, it is still advancing at a tremendous pace. Novel surgical techniques and devices are continuously developed and applied, and new indications (and/or contraindications) for the use of endoscopic surgery are routinely reported in the literature and subjected to systematic assessments. Although endoscopic surgery (laparoscopy in particular) has already become established as the gold standard in human medicine, it has yet to be proven as a viable alternative to open surgery in the field of veterinary medicine. The advantages of minimally invasive surgery include better intra-operative visualization, reduced postoperative pain, reduced scar formation and increased postoperative mobility. Therefore, it is reasonable to expect that the application of this will continue to expand. Small animal reproduction, a field within the broad discipline of veterinary medicine, has already recognized and begun to reap the benefits of endoscopic surgery. Herein, we retrospectively review the most recent successful novel applications of endoscopic surgery in the small animal reproduction system to provide small animal reproductive surgeons with important knowledge to help improve their own veterinarian medical practice. © 2016 Blackwell Verlag GmbH.

  19. Surgical dummy: a surrogate to live animal in teaching Veterinary ...

    African Journals Online (AJOL)

    The ethos of the course veterinary surgery is to install core surgical skills at the very start of a ... 2d to 4d nail gauges with large nail head. Cadaver ... Teaching model. Virtual surgery. Dummy. Cadaver. Live animal. Motor skill. -. ++. ++. ++.

  20. Antimicrobial stewardship in small animal veterinary practice

    DEFF Research Database (Denmark)

    Guardabassi, Luca; Prescott, John F

    2015-01-01

    Despite the increasing recognition of the critical role for antimicrobial stewardship in preventing the spread of multidrug-resistant bacteria, examples of effective antimicrobial stewardship programs are rare in small animal veterinary practice. This article highlights the basic requirements...

  1. Modality comparison for small animal radiotherapy: A simulation study

    Energy Technology Data Exchange (ETDEWEB)

    Bazalova, Magdalena, E-mail: bazalova@stanford.edu; Nelson, Geoff; Noll, John M.; Graves, Edward E. [Department of Radiation Oncology, Molecular Imaging Program at Stanford, Stanford University, Stanford, California 94305 (United States)

    2014-01-15

    Purpose: Small animal radiation therapy has advanced significantly in recent years. Whereas in the past dose was delivered using a single beam and a lead shield for sparing of healthy tissue, conformal doses can be now delivered using more complex dedicated small animal radiotherapy systems with image guidance. The goal of this paper is to investigate dose distributions for three small animal radiation treatment modalities. Methods: This paper presents a comparison of dose distributions generated by the three approaches—a single-field irradiator with a 200 kV beam and no image guidance, a small animal image-guided conformal system based on a modified microCT scanner with a 120 kV beam developed at Stanford University, and a dedicated conformal system, SARRP, using a 220 kV beam developed at Johns Hopkins University. The authors present a comparison of treatment plans for the three modalities using two cases: a mouse with a subcutaneous tumor and a mouse with a spontaneous lung tumor. A 5 Gy target dose was calculated using the EGSnrc Monte Carlo codes. Results: All treatment modalities generated similar dose distributions for the subcutaneous tumor case, with the highest mean dose to the ipsilateral lung and bones in the single-field plan (0.4 and 0.4 Gy) compared to the microCT (0.1 and 0.2 Gy) and SARRP (0.1 and 0.3 Gy) plans. The lung case demonstrated that due to the nine-beam arrangements in the conformal plans, the mean doses to the ipsilateral lung, spinal cord, and bones were significantly lower in the microCT plan (2.0, 0.4, and 1.9 Gy) and the SARRP plan (1.5, 0.5, and 1.8 Gy) than in single-field irradiator plan (4.5, 3.8, and 3.3 Gy). Similarly, the mean doses to the contralateral lung and the heart were lowest in the microCT plan (1.5 and 2.0 Gy), followed by the SARRP plan (1.7 and 2.2 Gy), and they were highest in the single-field plan (2.5 and 2.4 Gy). For both cases, dose uniformity was greatest in the single-field irradiator plan followed by

  2. On the surveillance for animal diseases in small herds

    DEFF Research Database (Denmark)

    Greiner, Matthias; Dekker, Aldo

    2005-01-01

    Small herds may present a problem in surveillance for infectious animal diseases because typical levels of a within-herd design prevalence are not directly applicable. We suggest a definition of small herds as those smaller than 2/(within-herd design prevalence) on the basis that such herds would...... be expected to have less than two (i.e. only one) infected animals. Consequently, the probability of detecting small herds cannot be improved by choosing a larger sample size within the herd. We derive necessary sample sizes of herds and the probability ("confidence") of detecting disease within a stratum...... conservative (lower) estimates of the confidence for a given sample size and should therefore be preferred....

  3. [Surveillance on severe acute respiratory syndrome associated coronavirus in animals at a live animal market of Guangzhou in 2004].

    Science.gov (United States)

    Wang, Ming; Jing, Huai-qi; Xu, Hui-fang; Jiang, Xiu-gao; Kan, Biao; Liu, Qi-yong; Wan, Kang-lin; Cui, Bu-yun; Zheng, Han; Cui, Zhi-gang; Yan, Mei-ying; Liang, Wei-li; Wang, Hong-xia; Qi, Xiao-bao; Li, Zhen-jun; Li, Ma-chao; Chen, Kai; Zhang, En-min; Zhang, Shou-yin; Hai, Rong; Yu, Dong-zheng; Xu, Jian-guo

    2005-02-01

    To study the prevalence of severe acute respiratory syndrome coronavirus (SARS-CoV) like virus in animals at a live animal market of Guanzhou in 2004 before and after culling of wild animal action taken by the local authority, in order to predict the re-emerging of SARS from animal originals in this region. Animals at live animal market were sampled for rectal and throat swabs in triplicate. A single step realtime reverse transcription-polymerase chain reaction (RT-PCR) diagnostic kit was performed for screening SARS-CoV like virus, the manual nested RT- PCR and DNA sequencing were performed for confirmation. Only specimens which tested positive for both of the N and P genes by nested RT-PCR were scored as positive. In 31 animals sampled in January 5 2004 before culling of wild animals at Guangdong Province, including 20 cats (Felis catus), 5 red fox (Vulpes vulpes) and 6 Lesser rice field rats (Rattus losea), 8 (25.8%) animals were tested positive for SARS-CoV like virus by RT-PCR methods, of which 4 cats, 3 red fox and one Lesser rice field rats were included. However, two weeks after culling of animals and disinfection of the market were implemented, in 119 animals sampled in January 20 2004, including 6 rabbits (Oryctolagus cuniculus), 13 cats, 46 red jungle fowl (Gallus gallus), 13 spotbill duck (Anas platyrhynchos), 10 greylag goose (Anser anser), 31 Chinese francolin (Franclinus pintadeanus), only rectal swab from one greylag goose was tested positive for SARS-CoV like virus. Furthermore, in 102 animals that including 14 greylag gooses, 3 cats, 5 rabbits, 9 spotbill duck (Anaspoecilorhyncha), 2 Chinese francolin (Franclinus pintadeanus), 8 common pheasant (Phasianus colchicus), 6 pigeons, 9 Chinese muntjac (Muntiacus reevesi), 19 wild boar (Sus scrofa), 16 Lesser rice field rats, 5 dogs, 1 mink (Mustela vison), 3 goats, 2 green peafowl (Pavo muticus) sampled in April, May, June, July, August and November, only rectal swab from one pig was tested positive

  4. Small animal MRI: clinical MRI as an interface to basic biomedical research

    International Nuclear Information System (INIS)

    Pinkernelle, J.G.; Stelter, L.; Hamm, B.; Teichgraeber, U.

    2008-01-01

    The demand for highly resolved small animal MRI for the purpose of biomedical research has increased constantly. Dedicated small animal MRI scanners working at ultra high field strengths from 4.7 to 7.0 T and even above are MRI at its best. However, using high resolution RF coils in clinical scanners up to 3.0 T, small animal MRI can achieve highly resolved images showing excellent tissue contrast. In fact, in abundant experimental studies, clinical MRI is used for small animal imaging. Mostly clinical RF coils in the single-loop design are applied. In addition, custom-built RF coils and even gradient inserts are used in a clinical scanner. For the reduction of moving artifacts, special MRI-compatible animal ECG und respiration devices are available. In conclusion, clinical devices offer broad availability, are less expense in combination with good imaging performance and provide a translational nature of imaging results. (orig.)

  5. Monte Carlo simulations in small animal PET imaging

    Energy Technology Data Exchange (ETDEWEB)

    Branco, Susana [Universidade de Lisboa, Faculdade de Ciencias, Instituto de Biofisica e Engenharia Biomedica, Lisbon (Portugal)], E-mail: susana.silva@fc.ul.pt; Jan, Sebastien [Service Hospitalier Frederic Joliot, CEA/DSV/DRM, Orsay (France); Almeida, Pedro [Universidade de Lisboa, Faculdade de Ciencias, Instituto de Biofisica e Engenharia Biomedica, Lisbon (Portugal)

    2007-10-01

    This work is based on the use of an implemented Positron Emission Tomography (PET) simulation system dedicated for small animal PET imaging. Geant4 Application for Tomographic Emission (GATE), a Monte Carlo simulation platform based on the Geant4 libraries, is well suited for modeling the microPET FOCUS system and to implement realistic phantoms, such as the MOBY phantom, and data maps from real examinations. The use of a microPET FOCUS simulation model with GATE has been validated for spatial resolution, counting rates performances, imaging contrast recovery and quantitative analysis. Results from realistic studies of the mouse body using {sup -}F and [{sup 18}F]FDG imaging protocols are presented. These simulations include the injection of realistic doses into the animal and realistic time framing. The results have shown that it is possible to simulate small animal PET acquisitions under realistic conditions, and are expected to be useful to improve the quantitative analysis in PET mouse body studies.

  6. Identification of Hotspots in the European Union for the Introduction of Four Zoonotic Arboviroses by Live Animal Trade

    Science.gov (United States)

    Durand, Benoit; Lecollinet, Sylvie; Beck, Cécile; Martínez-López, Beatriz; Balenghien, Thomas; Chevalier, Véronique

    2013-01-01

    Live animal trade is considered a major mode of introduction of viruses from enzootic foci into disease-free areas. Due to societal and behavioural changes, some wild animal species may nowadays be considered as pet species. The species diversity of animals involved in international trade is thus increasing. This could benefit pathogens that have a broad host range such as arboviruses. The objective of this study was to analyze the risk posed by live animal imports for the introduction, in the European Union (EU), of four arboviruses that affect human and horses: Eastern and Western equine encephalomyelitis, Venezuelan equine encephalitis and Japanese encephalitis. Importation data for a five-years period (2005-2009, extracted from the EU TRACES database), environmental data (used as a proxy for the presence of vectors) and horses and human population density data (impacting the occurrence of clinical cases) were combined to derive spatially explicit risk indicators for virus introduction and for the potential consequences of such introductions. Results showed the existence of hotspots where the introduction risk was the highest in Belgium, in the Netherlands and in the north of Italy. This risk was higher for Eastern equine encephalomyelitis (EEE) than for the three other diseases. It was mainly attributed to exotic pet species such as rodents, reptiles or cage birds, imported in small-sized containments from a wide variety of geographic origins. The increasing species and origin diversity of these animals may have in the future a strong impact on the risk of introduction of arboviruses in the EU. PMID:23894573

  7. Prompt gamma-ray imaging for small animals

    Science.gov (United States)

    Xu, Libai

    Small animal imaging is recognized as a powerful discovery tool for small animal modeling of human diseases, which is providing an important clue to complete understanding of disease mechanisms and is helping researchers develop and test new treatments. The current small animal imaging techniques include positron emission tomography (PET), single photon emission tomography (SPECT), computed tomography (CT), magnetic resonance imaging (MRI), and ultrasound (US). A new imaging modality called prompt gamma-ray imaging (PGI) has been identified and investigated primarily by Monte Carlo simulation. Currently it is suggested for use on small animals. This new technique could greatly enhance and extend the present capabilities of PET and SPECT imaging from ingested radioisotopes to the imaging of selected non-radioactive elements, such as Gd, Cd, Hg, and B, and has the great potential to be used in Neutron Cancer Therapy to monitor neutron distribution and neutron-capture agent distribution. This approach consists of irradiating small animals in the thermal neutron beam of a nuclear reactor to produce prompt gamma rays from the elements in the sample by the radiative capture (n, gamma) reaction. These prompt gamma rays are emitted in energies that are characteristic of each element and they are also produced in characteristic coincident chains. After measuring these prompt gamma rays by surrounding spectrometry array, the distribution of each element of interest in the sample is reconstructed from the mapping of each detected signature gamma ray by either electronic collimations or mechanical collimations. In addition, the transmitted neutrons from the beam can be simultaneously used for very sensitive anatomical imaging, which provides the registration for the elemental distributions obtained from PGI. The primary approach is to use Monte Carlo simulation methods either with the specific purpose code CEARCPG, developed at NC State University or with the general purpose

  8. An integrated multimodality image-guided robot system for small-animal imaging research

    International Nuclear Information System (INIS)

    Hsu, Wen-Lin; Hsin Wu, Tung; Hsu, Shih-Ming; Chen, Chia-Lin; Lee, Jason J.S.; Huang, Yung-Hui

    2011-01-01

    We design and construct an image-guided robot system for use in small-animal imaging research. This device allows the use of co-registered small-animal PET-MRI images to guide the movements of robotic controllers, which will accurately place a needle probe at any predetermined location inside, for example, a mouse tumor, for biological readouts without sacrificing the animal. This system is composed of three major components: an automated robot device, a CCD monitoring mechanism, and a multimodality registration implementation. Specifically, the CCD monitoring mechanism was used for correction and validation of the robot device. To demonstrate the value of the proposed system, we performed a tumor hypoxia study that involved FMISO small-animal PET imaging and the delivering of a pO 2 probe into the mouse tumor using the image-guided robot system. During our evaluation, the needle positioning error was found to be within 0.153±0.042 mm of desired placement; the phantom simulation errors were within 0.693±0.128 mm. In small-animal studies, the pO 2 probe measurements in the corresponding hypoxia areas showed good correlation with significant, low tissue oxygen tensions (less than 6 mmHg). We have confirmed the feasibility of the system and successfully applied it to small-animal investigations. The system could be easily adapted to extend to other biomedical investigations in the future.

  9. Greek classicism in living structure? Some deductive pathways in animal morphology.

    Science.gov (United States)

    Zweers, G A

    1985-01-01

    Classical temples in ancient Greece show two deterministic illusionistic principles of architecture, which govern their functional design: geometric proportionalism and a set of illusion-strengthening rules in the proportionalism's "stochastic margin". Animal morphology, in its mechanistic-deductive revival, applies just one architectural principle, which is not always satisfactory. Whether a "Greek Classical" situation occurs in the architecture of living structure is to be investigated by extreme testing with deductive methods. Three deductive methods for explanation of living structure in animal morphology are proposed: the parts, the compromise, and the transformation deduction. The methods are based upon the systems concept for an organism, the flow chart for a functionalistic picture, and the network chart for a structuralistic picture, whereas the "optimal design" serves as the architectural principle for living structure. These methods show clearly the high explanatory power of deductive methods in morphology, but they also make one open end most explicit: neutral issues do exist. Full explanation of living structure asks for three entries: functional design within architectural and transformational constraints. The transformational constraint brings necessarily in a stochastic component: an at random variation being a sort of "free management space". This variation must be a variation from the deterministic principle of the optimal design, since any transformation requires space for plasticity in structure and action, and flexibility in role fulfilling. Nevertheless, finally the question comes up whether for animal structure a similar situation exists as in Greek Classical temples. This means that the at random variation, that is found when the optimal design is used to explain structure, comprises apart from a stochastic part also real deviations being yet another deterministic part. This deterministic part could be a set of rules that governs

  10. The biological application of small animal PET imaging

    International Nuclear Information System (INIS)

    Myers, Ralph

    2001-01-01

    The short history of small animal PET is reviewed in the context of its application in the laboratory. Early work has demonstrated a role for the technique in both drug development and in the in vivo monitoring of neuroreceptor function with time. As spatial resolution approaches 1 mm, challenges in quantification remain. However, the ability to carry out animal PET studies that are analogous to human PET will form an important bridge between laboratory and clinical sciences

  11. ADVANCES IN ANIMAL WELFARE FOR FREE-LIVING ANIMALS.

    Science.gov (United States)

    2016-04-01

    Over several decades, animal welfare has grown into its own free-standing field of scientific study, from its early beginnings in laboratory animal research to eventually include exhibited animals and farm animals. While it has always been present to some degree, consideration of animal welfare for free-ranging animals has lagged behind, developing as a field of study in the last 20 yr or so. Part of that increase was that animal welfare legislation was finally applied to studies being done on free-ranging animals. But it is the appreciation by the biologists and veterinarians working on wild animals, in which the quality of their results is largely controlled by the quality of the animals they use in their studies, which has resulted in increased attention to the well-being or welfare of the animals that they use. Other important influences driving the recognition of wildlife welfare have been changes in the public's expectations of how wild animals are dealt with, a shift in focus of wildlife professionals from managing animals that can be hunted or angled to include nongame species, the decrease in participation in hunting and fishing by members of the public, and the entry of large numbers of women into fish and wildlife agencies and departments and into veterinary medicine. Technical improvements have allowed the safe capture and handling of large or dangerous animals as immobilization drugs and equipment have been developed. The increasing use of sedating drugs allows for handling of animals with reduced stress and other impacts. A number of topics, such as toe-clipping, branding, defining which taxa can or cannot feel pain, catch-and-release fishing, and more, remain controversial within wildlife science. How we treat the wild animals that we deal with defines who we are as wildlife professionals, and animal welfare concerns and techniques for free-ranging animals will continue to develop and evolve.

  12. Pre-clinical research in small animals using radiotherapy technology. A bidirectional translational approach

    International Nuclear Information System (INIS)

    Tillner, Falk; Buetof, Rebecca; Krause, Mechthild; Enghardt, Wolfgang; Helmholtz-Zentrum Dresden-Rossendorf, Dresden; Technische Univ. Dresden; Helmholtz-Zentrum Dresden-Rossendorf, Dresden

    2014-01-01

    For translational cancer research, pre-clinical in-vivo studies using small animals have become indispensable in bridging the gap between in-vitro cell experiments and clinical implementation. When setting up such small animal experiments, various biological, technical and methodical aspects have to be considered. In this work we present a comprehensive topical review based on relevant publications on irradiation techniques used for pre-clinical cancer research in mice and rats. Clinical radiotherapy treatment devices for the application of external beam radiotherapy and brachytherapy as well as dedicated research irradiation devices are feasible for small animal irradiation depending on the animal model and the experimental goals. In this work, appropriate solutions for the technological transfer of human radiation oncology to small animal radiation research are summarised. Additionally, important information concerning the experimental design is provided such that reliable and clinically relevant results can be attained.

  13. Pre-clinical research in small animals using radiotherapy technology. A bidirectional translational approach

    Energy Technology Data Exchange (ETDEWEB)

    Tillner, Falk; Buetof, Rebecca [Technische Univ. Dresden (Germany). OncoRay - National Center for Radiation Research in Oncology; Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Technische Univ. Dresden (Germany). Dept. of Radiation Oncology; Thute, Prasad [Technische Univ. Dresden (Germany). OncoRay - National Center for Radiation Research in Oncology; Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Krause, Mechthild [Technische Univ. Dresden (Germany). OncoRay - National Center for Radiation Research in Oncology; Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Technische Univ. Dresden (Germany). Dept. of Radiation Oncology; German Cancer Consortium (DKTK), Dresden (Germany); German Cancer Research Center (DKFZ), Heidelberg (Germany); Enghardt, Wolfgang [Technische Univ. Dresden (Germany). OncoRay - National Center for Radiation Research in Oncology; Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Technische Univ. Dresden (Germany). Dept. of Radiation Oncology; Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany). Inst. of Radiooncology

    2014-07-01

    For translational cancer research, pre-clinical in-vivo studies using small animals have become indispensable in bridging the gap between in-vitro cell experiments and clinical implementation. When setting up such small animal experiments, various biological, technical and methodical aspects have to be considered. In this work we present a comprehensive topical review based on relevant publications on irradiation techniques used for pre-clinical cancer research in mice and rats. Clinical radiotherapy treatment devices for the application of external beam radiotherapy and brachytherapy as well as dedicated research irradiation devices are feasible for small animal irradiation depending on the animal model and the experimental goals. In this work, appropriate solutions for the technological transfer of human radiation oncology to small animal radiation research are summarised. Additionally, important information concerning the experimental design is provided such that reliable and clinically relevant results can be attained.

  14. Techniques necessary for multiple tracer quantitative small-animal imaging studies

    International Nuclear Information System (INIS)

    Sharp, Terry L.; Dence, Carmen S.; Engelbach, John A.; Herrero, Pilar; Gropler, Robert J.; Welch, Michael J.

    2005-01-01

    Introduction: An increasing number and variety of studies on rodent models are being conducted using small-animal positron emission tomography scanners. We aimed to determine if animal handling techniques could be developed to perform routine animal imaging in a timely and efficient manner and with minimal effect on animal physiology. These techniques need to be reproducible in the same animal while maintaining hemodynamic and physiological stability. Methods: The necessary techniques include (a) the use of inhalant anesthesia, (b) arterial and venous cannulation for multiple tracer administrations and blood sampling, (c) development of small-volume analytic columns and techniques and (d) measurement of the physiological environment during the imaging session. Results: We provide an example of a cardiac imaging study using four radiotracers ( 15 O-water, 1-[ 11 C]-acetate, 1-[ 11 C]-palmitate and 1-[ 11 C]-glucose) injected into normal rats. Plasma substrates, CO 2 production and total metabolites were measured. The animals remained anesthetized over the entire imaging session, and their physiological state was maintained. Conclusion: The intrastudy stability of the physiological measurements and substrate levels and interstudy reproducibility of the measurements are reported

  15. Management of occupational health risks in small-animal veterinary practices.

    Science.gov (United States)

    D'Souza, Eva; Barraclough, Richard; Fishwick, David; Curran, Andrew

    2009-08-01

    Small-animal work is a major element of veterinary practice in the UK and may be hazardous, with high levels of work-related injuries and ill-health reported in Australia and USA. There are no studies addressing the management of occupational health risks arising from small-animal work in the UK. To investigate the sources of health and safety information used and how health and safety and 12 specific occupational health risks are managed by practices. A cross-sectional postal survey of all small-animal veterinary practices in Hampshire. A response was mandatory as this was a Health & Safety Executive (HSE) inspection activity. A total of 118 (100%) practices responded of which 93 were eligible for inclusion. Of these, 99 and 86%, respectively, were aware of the Royal College of Veterinary Surgeons (RCVS) practice standards and had British Small Animal Veterinary Association (BSAVA) staff members, while only 51% had previous contact with HSE (publications, advice and visit). Ninety per cent had health and safety policies, but only 31% had trained responsible staff in health and safety. Specific health hazards such as occupational allergens and computer use were relatively overlooked both by practices and the RCVS/BSAVA guidance available in 2002. Failings in active health risk management systems could be due to a lack of training to ensure competence in those with responsibilities. Practices rely on guidance produced by their professional bodies. Current RCVS guidance, available since 2005, has remedied some previous omissions, but further improvements are recommended.

  16. Pre-clinical research in small animals using radiotherapy technology--a bidirectional translational approach.

    Science.gov (United States)

    Tillner, Falk; Thute, Prasad; Bütof, Rebecca; Krause, Mechthild; Enghardt, Wolfgang

    2014-12-01

    For translational cancer research, pre-clinical in-vivo studies using small animals have become indispensable in bridging the gap between in-vitro cell experiments and clinical implementation. When setting up such small animal experiments, various biological, technical and methodical aspects have to be considered. In this work we present a comprehensive topical review based on relevant publications on irradiation techniques used for pre-clinical cancer research in mice and rats. Clinical radiotherapy treatment devices for the application of external beam radiotherapy and brachytherapy as well as dedicated research irradiation devices are feasible for small animal irradiation depending on the animal model and the experimental goals. In this work, appropriate solutions for the technological transfer of human radiation oncology to small animal radiation research are summarised. Additionally, important information concerning the experimental design is provided such that reliable and clinically relevant results can be attained. Copyright © 2014. Published by Elsevier GmbH.

  17. Non-Invasive in vivo Imaging in Small Animal Research

    Directory of Open Access Journals (Sweden)

    V. Koo

    2006-01-01

    Full Text Available Non-invasive real time in vivo molecular imaging in small animal models has become the essential bridge between in vitro data and their translation into clinical applications. The tremendous development and technological progress, such as tumour modelling, monitoring of tumour growth and detection of metastasis, has facilitated translational drug development. This has added to our knowledge on carcinogenesis. The modalities that are commonly used include Magnetic Resonance Imaging (MRI, Computed Tomography (CT, Positron Emission Tomography (PET, bioluminescence imaging, fluorescence imaging and multi-modality imaging systems. The ability to obtain multiple images longitudinally provides reliable information whilst reducing animal numbers. As yet there is no one modality that is ideal for all experimental studies. This review outlines the instrumentation available together with corresponding applications reported in the literature with particular emphasis on cancer research. Advantages and limitations to current imaging technology are discussed and the issues concerning small animal care during imaging are highlighted.

  18. Hyperpolarized singlet NMR on a small animal imaging system

    DEFF Research Database (Denmark)

    Laustsen, Christoffer; Pileio, Giuseppe; Tayler, Michael C. D.

    2012-01-01

    Nuclear spin hyperpolarization makes a significant advance toward overcoming the sensitivity limitations of in vivo magnetic resonance imaging, particularly in the case of low-gamma nuclei. The sensitivity may be improved further by storing the hyperpolarization in slowly relaxing singlet...... populations of spin- 1/2 pairs. Here, we report hyperpolarized 13C spin order transferred into and retrieved from singlet spin order using a small animal magnetic resonance imaging scanner. For spins in sites with very similar chemical shifts, singlet spin order is sustained in high magnetic field without...... requiring strong radiofrequency irradiation. The demonstration of robust singlet-to-magnetization conversion, and vice versa, on a small animal scanner, is promising for future in vivo and clinical deployments....

  19. Measuring of main parameters of blood circulation at small laboratory animals in chronic experiment by means of computerized gamma-camera

    International Nuclear Information System (INIS)

    Rutskij, A.V.; Kovalenko, Yu.D.; Rudenko, F.V.; Ioda, G.I.; Kaminskij, M.P.

    1996-01-01

    Technique for studding of a state systemic and regional hemodynamics at small laboratory animals (rats) by using short-lived isotopes (technetium 99 m) and computerized gamma-camera are described. One gives possibility to make the repeated measuring in condition long-tome experiment. The proposed technique of radiocardiocirculography gives possibility simultaneously to measure linear parameters of both arterial and vein blood circulation too. 3 refs., 1 tab., 2 figs

  20. Marketing small animal theriogenology services--one perspective.

    Science.gov (United States)

    Barber, J A

    2007-08-01

    Once a decision is made to add small animal theriogenology services to a practice, marketing strategies must be developed and implemented to attract clients to the new services. Marketing strategies for the niche market of theriogenology include start-up marketing methods, referral programs, internal marketing, and continued marketing. Marketing theriogenology services is a dynamic, ongoing process that never ends.

  1. Hyperspectral small animal fluorescence imaging: spectral selection imaging

    Science.gov (United States)

    Leavesley, Silas; Jiang, Yanan; Patsekin, Valery; Hall, Heidi; Vizard, Douglas; Robinson, J. Paul

    2008-02-01

    Molecular imaging is a rapidly growing area of research, fueled by needs in pharmaceutical drug-development for methods for high-throughput screening, pre-clinical and clinical screening for visualizing tumor growth and drug targeting, and a growing number of applications in the molecular biology fields. Small animal fluorescence imaging employs fluorescent probes to target molecular events in vivo, with a large number of molecular targeting probes readily available. The ease at which new targeting compounds can be developed, the short acquisition times, and the low cost (compared to microCT, MRI, or PET) makes fluorescence imaging attractive. However, small animal fluorescence imaging suffers from high optical scattering, absorption, and autofluorescence. Much of these problems can be overcome through multispectral imaging techniques, which collect images at different fluorescence emission wavelengths, followed by analysis, classification, and spectral deconvolution methods to isolate signals from fluorescence emission. We present an alternative to the current method, using hyperspectral excitation scanning (spectral selection imaging), a technique that allows excitation at any wavelength in the visible and near-infrared wavelength range. In many cases, excitation imaging may be more effective at identifying specific fluorescence signals because of the higher complexity of the fluorophore excitation spectrum. Because the excitation is filtered and not the emission, the resolution limit and image shift imposed by acousto-optic tunable filters have no effect on imager performance. We will discuss design of the imager, optimizing the imager for use in small animal fluorescence imaging, and application of spectral analysis and classification methods for identifying specific fluorescence signals.

  2. SU-E-U-02: The Development of a Practical Ultrasonic System for Cross-Sectional Imaging of Small Animals

    Energy Technology Data Exchange (ETDEWEB)

    Kamp, J [Wayne State University, Detroit, MI (United States); Karmanos Cancer Institute - International Imaging Center, Detroit, MI (United States); Malyarenko, E [Karmanos Cancer Institute - International Imaging Center, Detroit, MI (United States); Tessonics Corp, Birmingham, MI (United Kingdom); Chen, D [Karmanos Cancer Institute - International Imaging Center, Detroit, MI (United States); Wydra, A [True Phantoms Solutions, Windsor, ON (Canada); University of Windsor - Institute for Diagnostic Imaging Research, Windsor, ON (Canada); Maev, R [Wayne State University, Detroit, MI (United States); Karmanos Cancer Institute - International Imaging Center, Detroit, MI (United States); Tessonics Corp, Birmingham, MI (United Kingdom); True Phantoms Solutions, Windsor, ON (Canada); University of Windsor - Institute for Diagnostic Imaging Research, Windsor, ON (Canada)

    2015-06-15

    Purpose: To test the feasibility of developing a practical medium frequency ultrasound tomography method for small animal imaging. The ability to produce cross-sectional or full body images of a live small animal using a low-cost tabletop ultrasound scanner without any special license would be very beneficial to long term biological studies, where repeated scanning is often required over an extended period of time. Methods: The cross sectional images were produced by compounding multiple B-scans of a laboratory phantom or an animal acquired at different projection angles. Two imaging systems were used to test the concept. The first system included a programmable 64-channel phased array controller driving a 128-channel, 5–10 MHz linear probe to produce 143 B-Mode projections of the spinning object. The second system designed and manufactured in house, produced 64 or 128 B-Mode projections with a single unfocused 8 MHz transducer scanning with a 0.116 mm step size. Results: The phased array system provided good penetration through the phantoms/mice (with the exception of the lungs) and allowed to acquire data in a very short time. The cross-sectional images have enough resolution and dynamic range to detect both high- and low-contrast organs. The single transducer system takes longer to scan, and the data require more sophisticated processing. To date, our images allow seeing details as small as 1–2 mm in the phantoms and in small animals, with the contrast mostly due to highly reflecting bones and air inclusions. Conclusion: The work indicates that very detailed and anatomically correct images can be created by relatively simple and inexpensive means. With more advanced algorithms and improved system design, scan time can be reduced considerably, enabling high-resolution full 3D imaging. This will allow for quick and easy scans that can help monitor tumor growth and/or regression without contributing any dose to the animal. The authors would like to acknowledge

  3. Small Animal Massage Therapy: A Brief Review and Relevant Observations.

    Science.gov (United States)

    Formenton, Maira Rezende; Pereira, Marco Aurélio Amador; Fantoni, Denise Tabacchi

    2017-12-01

    Massage therapy is becoming increasingly popular in human and animal physiotherapy and rehabilitation. Wider application of the technique led to research efforts aimed at providing scientific support to anecdotal beneficial effects, particularly pain relief. Recent studies have shown that massage therapy alters dopamine and serotonin levels, decreases noradrenaline levels, and modulates the immune system. Psychological effects such as reduction of stress and anxiety, with improvement of depressive patients, have been reported in humans. This article set out to review the major aspects of massage therapy based on recent publications on the topic, and to extrapolate concepts and practical aspects described in human physiotherapy to the veterinary patient, particularly the applicability of different techniques in Small Animal Medicine. Indications of massage therapy in small animals include pain relief, orthopedic rehabilitation, Canine Sports Medicine, intensive care, and management of nonspecific edema. Techniques described in this article were originally intended for use in humans and scientific data supporting anecdotal, beneficial effects in domestic animals are still lacking; this fruitful area for research is therefore open to veterinary professionals. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Preliminary study for small animal preclinical hadrontherapy facility

    Energy Technology Data Exchange (ETDEWEB)

    Russo, G. [Institute of Molecular Bioimaging and Physiology, IBFM CNR-LATO, Cefalú (Italy); Pisciotta, P., E-mail: pietro.pisciotta@ibfm.cnr.it [Institute of Molecular Bioimaging and Physiology, IBFM CNR-LATO, Cefalú (Italy); National Institute for Nuclear Physics, Laboratori Nazionali del Sud, INFN-LNS, Catania (Italy); Cirrone, G.A.P.; Romano, F. [National Institute for Nuclear Physics, Laboratori Nazionali del Sud, INFN-LNS, Catania (Italy); Cammarata, F.; Marchese, V.; Forte, G.I.; Lamia, D.; Minafra, L.; Bravatá, V. [Institute of Molecular Bioimaging and Physiology, IBFM CNR-LATO, Cefalú (Italy); Acquaviva, R. [University of Catania, Catania (Italy); Gilardi, M.C. [Institute of Molecular Bioimaging and Physiology, IBFM CNR-LATO, Cefalú (Italy); Cuttone, G. [National Institute for Nuclear Physics, Laboratori Nazionali del Sud, INFN-LNS, Catania (Italy)

    2017-02-21

    Aim of this work is the study of the preliminary steps to perform a particle treatment of cancer cells inoculated in small animals and to realize a preclinical hadrontherapy facility. A well-defined dosimetric protocol was developed to explicate the steps needed in order to perform a precise proton irradiation in small animals and achieve a highly conformal dose into the target. A precise homemade positioning and holding system for small animals was designed and developed at INFN-LNS in Catania (Italy), where an accurate Monte Carlo simulation was developed, using Geant4 code to simulate the treatment in order to choose the best animal position and perform accurately all the necessary dosimetric evaluations. The Geant4 application can also be used to realize dosimetric studies and its peculiarity consists in the possibility to introduce the real target composition in the simulation using the DICOM micro-CT image. This application was fully validated comparing the results with the experimental measurements. The latter ones were performed at the CATANA (Centro di AdroTerapia e Applicazioni Nucleari Avanzate) facility at INFN-LNS by irradiating both PMMA and water solid phantom. Dosimetric measurements were performed using previously calibrated EBT3 Gafchromic films as a detector and the results were compared with the Geant4 simulation ones. In particular, two different types of dosimetric studies were performed: the first one involved irradiation of a phantom made up of water solid slabs where a layer of EBT3 was alternated with two different slabs in a sandwich configuration, in order to validate the dosimetric distribution. The second one involved irradiation of a PMMA phantom made up of a half hemisphere and some PMMA slabs in order to simulate a subcutaneous tumour configuration, normally used in preclinical studies. In order to evaluate the accordance between experimental and simulation results, two different statistical tests were made: Kolmogorov test and

  5. Preliminary study for small animal preclinical hadrontherapy facility

    Science.gov (United States)

    Russo, G.; Pisciotta, P.; Cirrone, G. A. P.; Romano, F.; Cammarata, F.; Marchese, V.; Forte, G. I.; Lamia, D.; Minafra, L.; Bravatá, V.; Acquaviva, R.; Gilardi, M. C.; Cuttone, G.

    2017-02-01

    Aim of this work is the study of the preliminary steps to perform a particle treatment of cancer cells inoculated in small animals and to realize a preclinical hadrontherapy facility. A well-defined dosimetric protocol was developed to explicate the steps needed in order to perform a precise proton irradiation in small animals and achieve a highly conformal dose into the target. A precise homemade positioning and holding system for small animals was designed and developed at INFN-LNS in Catania (Italy), where an accurate Monte Carlo simulation was developed, using Geant4 code to simulate the treatment in order to choose the best animal position and perform accurately all the necessary dosimetric evaluations. The Geant4 application can also be used to realize dosimetric studies and its peculiarity consists in the possibility to introduce the real target composition in the simulation using the DICOM micro-CT image. This application was fully validated comparing the results with the experimental measurements. The latter ones were performed at the CATANA (Centro di AdroTerapia e Applicazioni Nucleari Avanzate) facility at INFN-LNS by irradiating both PMMA and water solid phantom. Dosimetric measurements were performed using previously calibrated EBT3 Gafchromic films as a detector and the results were compared with the Geant4 simulation ones. In particular, two different types of dosimetric studies were performed: the first one involved irradiation of a phantom made up of water solid slabs where a layer of EBT3 was alternated with two different slabs in a sandwich configuration, in order to validate the dosimetric distribution. The second one involved irradiation of a PMMA phantom made up of a half hemisphere and some PMMA slabs in order to simulate a subcutaneous tumour configuration, normally used in preclinical studies. In order to evaluate the accordance between experimental and simulation results, two different statistical tests were made: Kolmogorov test and

  6. Preliminary study for small animal preclinical hadrontherapy facility

    International Nuclear Information System (INIS)

    Russo, G.; Pisciotta, P.; Cirrone, G.A.P.; Romano, F.; Cammarata, F.; Marchese, V.; Forte, G.I.; Lamia, D.; Minafra, L.; Bravatá, V.; Acquaviva, R.; Gilardi, M.C.; Cuttone, G.

    2017-01-01

    Aim of this work is the study of the preliminary steps to perform a particle treatment of cancer cells inoculated in small animals and to realize a preclinical hadrontherapy facility. A well-defined dosimetric protocol was developed to explicate the steps needed in order to perform a precise proton irradiation in small animals and achieve a highly conformal dose into the target. A precise homemade positioning and holding system for small animals was designed and developed at INFN-LNS in Catania (Italy), where an accurate Monte Carlo simulation was developed, using Geant4 code to simulate the treatment in order to choose the best animal position and perform accurately all the necessary dosimetric evaluations. The Geant4 application can also be used to realize dosimetric studies and its peculiarity consists in the possibility to introduce the real target composition in the simulation using the DICOM micro-CT image. This application was fully validated comparing the results with the experimental measurements. The latter ones were performed at the CATANA (Centro di AdroTerapia e Applicazioni Nucleari Avanzate) facility at INFN-LNS by irradiating both PMMA and water solid phantom. Dosimetric measurements were performed using previously calibrated EBT3 Gafchromic films as a detector and the results were compared with the Geant4 simulation ones. In particular, two different types of dosimetric studies were performed: the first one involved irradiation of a phantom made up of water solid slabs where a layer of EBT3 was alternated with two different slabs in a sandwich configuration, in order to validate the dosimetric distribution. The second one involved irradiation of a PMMA phantom made up of a half hemisphere and some PMMA slabs in order to simulate a subcutaneous tumour configuration, normally used in preclinical studies. In order to evaluate the accordance between experimental and simulation results, two different statistical tests were made: Kolmogorov test and

  7. Technical note - Considerations for MR imaging of small animals

    International Nuclear Information System (INIS)

    Baker, Martin A.

    2011-01-01

    Routine clinical veterinary use of MR scanning is becoming more common. This article addresses the major technical considerations for radiographers performing MR examinations on small animals and provides practical advice for scanning techniques.

  8. Dry coupling for whole-body small-animal photoacoustic computed tomography

    Science.gov (United States)

    Yeh, Chenghung; Li, Lei; Zhu, Liren; Xia, Jun; Li, Chiye; Chen, Wanyi; Garcia-Uribe, Alejandro; Maslov, Konstantin I.; Wang, Lihong V.

    2017-04-01

    We have enhanced photoacoustic computed tomography with dry acoustic coupling that eliminates water immersion anxiety and wrinkling of the animal and facilitates incorporating complementary modalities and procedures. The dry acoustic coupler is made of a tubular elastic membrane enclosed by a closed transparent water tank. The tubular membrane ensures water-free contact with the animal, and the closed water tank allows pressurization for animal stabilization. The dry coupler was tested using a whole-body small-animal ring-shaped photoacoustic computed tomography system. Dry coupling was found to provide image quality comparable to that of conventional water coupling.

  9. Application of MOSFET detectors for dosimetry in small animal radiography using short exposure times.

    Science.gov (United States)

    De Lin, Ming; Toncheva, Greta; Nguyen, Giao; Kim, Sangroh; Anderson-Evans, Colin; Johnson, G Allan; Yoshizumi, Terry T

    2008-08-01

    Digital subtraction angiography (DSA) X-ray imaging for small animals can be used for functional phenotyping given its ability to capture rapid physiological changes at high spatial and temporal resolution. The higher temporal and spatial requirements for small-animal imaging drive the need for short, high-flux X-ray pulses. However, high doses of ionizing radiation can affect the physiology. The purpose of this study was to verify and apply metal oxide semiconductor field effect transistor (MOSFET) technology to dosimetry for small-animal diagnostic imaging. A tungsten anode X-ray source was used to expose a tissue-equivalent mouse phantom. Dose measurements were made on the phantom surface and interior. The MOSFETs were verified with thermoluminescence dosimeters (TLDs). Bland-Altman analysis showed that the MOSFET results agreed with the TLD results (bias, 0.0625). Using typical small animal DSA scan parameters, the dose ranged from 0.7 to 2.2 cGy. Application of the MOSFETs in the small animal environment provided two main benefits: (1) the availability of results in near real-time instead of the hours needed for TLD processes and (2) the ability to support multiple exposures with different X-ray techniques (various of kVp, mA and ms) using the same MOSFET. This MOSFET technology has proven to be a fast, reliable small animal dosimetry method for DSA imaging and is a good system for dose monitoring for serial and gene expression studies.

  10. Precise image-guided irradiation of small animals: a flexible non-profit platform

    International Nuclear Information System (INIS)

    Tillner, Falk; Thute, Prasad; Löck, Steffen; Dietrich, Antje; Fursov, Andriy; Haase, Robert; Lukas, Mathias; Krause, Mechthild; Baumann, Michael; Bütof, Rebecca; Enghardt, Wolfgang; Rimarzig, Bernd; Sobiella, Manfred

    2016-01-01

    Preclinical in vivo studies using small animals are essential to develop new therapeutic options in radiation oncology. Of particular interest are orthotopic tumour models, which better reflect the clinical situation in terms of growth patterns and microenvironmental parameters of the tumour as well as the interplay of tumours with the surrounding normal tissues. Such orthotopic models increase the technical demands and the complexity of preclinical studies as local irradiation with therapeutically relevant doses requires image-guided target localisation and accurate beam application. Moreover, advanced imaging techniques are needed for monitoring treatment outcome. We present a novel small animal image-guided radiation therapy (SAIGRT) system, which allows for precise and accurate, conformal irradiation and x-ray imaging of small animals. High accuracy is achieved by its robust construction, the precise movement of its components and a fast high-resolution flat-panel detector. Field forming and x-ray imaging is accomplished close to the animal resulting in a small penumbra and a high image quality. Feasibility for irradiating orthotopic models has been proven using lung tumour and glioblastoma models in mice. The SAIGRT system provides a flexible, non-profit academic research platform which can be adapted to specific experimental needs and therefore enables systematic preclinical trials in multicentre research networks. (paper)

  11. A living model for obesity and aging research: Caenorhabditis elegans.

    Science.gov (United States)

    Shen, Peiyi; Yue, Yiren; Park, Yeonhwa

    2018-03-24

    Caenorhabditis elegans (C. elegans) is a free-living nematode that has been extensively utilized as an animal model for research involving aging and neurodegenerative diseases, like Alzheimer's and Parkinson's, etc. Compared with traditional animal models, this small nematode possesses many benefits, such as small body size, short lifespan, completely sequenced genome, and more than 65% of the genes associated with human disease. All these characteristics make this organism an ideal living system for obesity and aging studies. This review gives a brief introduction of C. elegans as an animal model, highlights some advantages of research using this model and describes methods to evaluate the effect of treatments on obesity and aging of this organism.

  12. The Usage of Animals in the Lives of the Lanoh and Temiar Tribes of Lenggong, Perak

    Directory of Open Access Journals (Sweden)

    Yahaya Fatan Hamamah

    2015-01-01

    Full Text Available In Malaysia, the Orang Asli communities are natives that comprise the Negrito, Senoi and Proto-Malay peoples. Traditionally, the Orang Asli live in isolated forests or in forest peripheries. Although Globalisation occurs in Malaysia, its occurrence does not affect the traditional values of the said Orang Asli, who still depend on the natural environment to live. Nature provides the Orang Asli with a community resource for acquiring animals that are not just consumed as food, but also used in medicine, hunting and myth creation. This study intends to identify the animal species and the methods the Senoi and Negrito use these animals, within the aspects of their diet, medicine, hunting methods and their myth creation. Empirical data collection is focused only on the Lanoh and Temiar tribes who live in Lenggong. The method of data collection involves in-depth interviews with key informants that comprise Tok Batins (tribal chiefs and focus groups from the chosen Orang Asli village communities in Kampung Air Bah and Kampung Lubuk Chupak, Lenggong. The findings of this study reveal a wide variety of animals are still being hunted by the Orang Asli community for food and medicine. Apart from that, there are specific beliefs regarding the animals hunted narrated through myths and legends. Therefore, this study is significant in order to determine that the animal usage in the lives of the Orang Asli community continue for the sake of the demands of their heritage and families in order to preserve its pristine continuity. This is because while findings show that wildlife is still used by the Orang Asli, their usage among the younger generation is increasingly eroded due to such factors as wildlife extinction, dwindling availability, new religious taboos and modern progress which continues to find its place within the Orang Asli community.

  13. Euthanasia of Small Animals with Nitrogen; Comparison with Intravenous Pentobarbital

    OpenAIRE

    Quine, John P.; Buckingham, William; Strunin, Leo

    1988-01-01

    Intravenous pentobarbital (with or without addition of saturated potassium chloride) was compared with nitrogen gas exposure for euthanasia of small animals (dogs, cats, and rabbits) in a humane society environment. Initially, electrocardiographic) and electroencephalographic monitoring were used to establish the time of death in presedated animals given either pentobarbital or exposed to nitrogen; later, nitrogen euthanasia alone was studied. Sedation with acepromazine delayed the effects of...

  14. In vivo small animal imaging: Current status and future prospects

    International Nuclear Information System (INIS)

    Kagadis, George C.; Loudos, George; Katsanos, Konstantinos; Langer, Steve G.; Nikiforidis, George C.

    2010-01-01

    The use of small animal models in basic and preclinical sciences constitutes an integral part of testing new pharmaceutical agents prior to commercial translation to clinical practice. Whole-body small animal imaging is a particularly elegant and cost-effective experimental platform for the timely validation and commercialization of novel agents from the bench to the bedside. Biomedical imaging is now listed along with genomics, proteomics, and metabolomics as an integral part of biological and medical sciences. Miniaturized versions of clinical diagnostic modalities, including but not limited to microcomputed tomography, micromagnetic resonance tomography, microsingle-photon-emission tomography, micropositron-emission tomography, optical imaging, digital angiography, and ultrasound, have all greatly improved our investigative abilities to longitudinally study various experimental models of human disease in mice and rodents. After an exhaustive literature search, the authors present a concise and critical review of in vivo small animal imaging, focusing on currently available modalities as well as emerging imaging technologies on one side and molecularly targeted contrast agents on the other. Aforementioned scientific topics are analyzed in the context of cancer angiogenesis and innovative antiangiogenic strategies under-the-way to the clinic. Proposed hybrid approaches for diagnosis and targeted site-specific therapy are highlighted to offer an intriguing glimpse of the future.

  15. Quantification in dynamic and small-animal positron emission tomography

    NARCIS (Netherlands)

    Disselhorst, Johannes Antonius

    2011-01-01

    This thesis covers two aspects of positron emission tomography (PET) quantification. The first section addresses the characterization and optimization of a small-animal PET/CT scanner. The sensitivity and resolution as well as various parameters affecting image quality (reconstruction settings, type

  16. Living with companion animals after stroke: experiences of older people in community and primary care nursing.

    Science.gov (United States)

    Johansson, Maria; Ahlström, Gerd; Jönsson, Ann-Cathrin

    2014-12-01

    Older people often have companion animals, and the significance of animals in human lives should be considered by nurses-particularly in relation to older people's health, which can be affected by diseases. The incidence of stroke increases with age and disabilities as a result of stroke are common. This study aimed to explore older people's experiences of living with companion animals after stroke, and their life situation with the animals in relation to the physical, psychological and social aspects of recovery after stroke. The study was performed using individual interviews approximately 2 years after stroke with 17 participants (10 women and 7 men) aged 62-88 years. An overarching theme arising from the content analysis was contribution to a meaningful life. This theme was generated from four categories: motivation for physical and psychosocial recovery after stroke; someone to care for who cares for you; animals as family members; and providers of safety and protection. The main conclusion was that companion animals are experienced as physical and psychosocial contributors to recovery and a meaningful life after stroke.

  17. Integration of optical imaging with a small animal irradiator

    International Nuclear Information System (INIS)

    Weersink, Robert A.; Ansell, Steve; Wang, An; Wilson, Graham; Shah, Duoaud; Lindsay, Patricia E.; Jaffray, David A.

    2014-01-01

    Purpose: The authors describe the integration of optical imaging with a targeted small animal irradiator device, focusing on design, instrumentation, 2D to 3D image registration, 2D targeting, and the accuracy of recovering and mapping the optical signal to a 3D surface generated from the cone-beam computed tomography (CBCT) imaging. The integration of optical imaging will improve targeting of the radiation treatment and offer longitudinal tracking of tumor response of small animal models treated using the system. Methods: The existing image-guided small animal irradiator consists of a variable kilovolt (peak) x-ray tube mounted opposite an aSi flat panel detector, both mounted on a c-arm gantry. The tube is used for both CBCT imaging and targeted irradiation. The optical component employs a CCD camera perpendicular to the x-ray treatment/imaging axis with a computer controlled filter for spectral decomposition. Multiple optical images can be acquired at any angle as the gantry rotates. The optical to CBCT registration, which uses a standard pinhole camera model, was modeled and tested using phantoms with markers visible in both optical and CBCT images. Optically guided 2D targeting in the anterior/posterior direction was tested on an anthropomorphic mouse phantom with embedded light sources. The accuracy of the mapping of optical signal to the CBCT surface was tested using the same mouse phantom. A surface mesh of the phantom was generated based on the CBCT image and optical intensities projected onto the surface. The measured surface intensity was compared to calculated surface for a point source at the actual source position. The point-source position was also optimized to provide the closest match between measured and calculated intensities, and the distance between the optimized and actual source positions was then calculated. This process was repeated for multiple wavelengths and sources. Results: The optical to CBCT registration error was 0.8 mm. Two

  18. Development of a SiPM-based PET imaging system for small animals

    International Nuclear Information System (INIS)

    Lu, Yanye; Yang, Kun; Zhou, Kedi; Zhang, Qiushi; Pang, Bo; Ren, Qiushi

    2014-01-01

    Advances in small animal positron emission tomography (PET) imaging have been accelerated by many new technologies such as the successful incorporation of silicon photomultiplier (SiPM). In this paper, we have developed a compact, lightweight PET imaging system that is based on SiPM detectors for small animals imaging, which could be integrated into a multi-modality imaging system. This PET imaging system consists of a stationary detector gantry, a motor-controlled animal bed module, electronics modules, and power supply modules. The PET detector, which was designed as a multi-slice circular ring geometry of 27 discrete block detectors, is composed of a cerium doped lutetium–yttrium oxyorthosilicate (LYSO) scintillation crystal and SiPM arrays. The system has a 60 mm transaxial field of view (FOV) and a 26 mm axial FOV. Performance tests (e.g. spatial resolution, energy resolution, and sensitivity) and phantom and animal imaging studies were performed to evaluate the imaging performance of the PET imaging system. The performance tests and animal imaging results demonstrate the feasibility of an animal PET system based on SiPM detectors and indicate that SiPM detectors can be promising photodetectors in animal PET instrumentation development

  19. Development of a SiPM-based PET imaging system for small animals

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Yanye [Department of Biomedicine and Engineering, College of Engineering, Peking University, Beijing 100871 (China); Yang, Kun, E-mail: yangkun9999@hotmail.com [Department of Control Technology and Instrumentation, College of Quality and Technical Supervision, Hebei University, Baoding, 071000 (China); Zhou, Kedi; Zhang, Qiushi; Pang, Bo [Department of Biomedicine and Engineering, College of Engineering, Peking University, Beijing 100871 (China); Ren, Qiushi, E-mail: renqsh@coe.pku.edu.cn [Department of Biomedicine and Engineering, College of Engineering, Peking University, Beijing 100871 (China)

    2014-04-11

    Advances in small animal positron emission tomography (PET) imaging have been accelerated by many new technologies such as the successful incorporation of silicon photomultiplier (SiPM). In this paper, we have developed a compact, lightweight PET imaging system that is based on SiPM detectors for small animals imaging, which could be integrated into a multi-modality imaging system. This PET imaging system consists of a stationary detector gantry, a motor-controlled animal bed module, electronics modules, and power supply modules. The PET detector, which was designed as a multi-slice circular ring geometry of 27 discrete block detectors, is composed of a cerium doped lutetium–yttrium oxyorthosilicate (LYSO) scintillation crystal and SiPM arrays. The system has a 60 mm transaxial field of view (FOV) and a 26 mm axial FOV. Performance tests (e.g. spatial resolution, energy resolution, and sensitivity) and phantom and animal imaging studies were performed to evaluate the imaging performance of the PET imaging system. The performance tests and animal imaging results demonstrate the feasibility of an animal PET system based on SiPM detectors and indicate that SiPM detectors can be promising photodetectors in animal PET instrumentation development.

  20. Coded Aperture Nuclear Scintigraphy: A Novel Small Animal Imaging Technique

    Directory of Open Access Journals (Sweden)

    Dawid Schellingerhout

    2002-10-01

    Full Text Available We introduce and demonstrate the utility of coded aperture (CA nuclear scintigraphy for imaging small animals. CA imaging uses multiple pinholes in a carefully designed mask pattern, mounted on a conventional gamma camera. System performance was assessed using point sources and phantoms, while several animal experiments were performed to test the usefulness of the imaging system in vivo, with commonly used radiopharmaceuticals. The sensitivity of the CA system for 99mTc was 4.2 × 103 cps/Bq (9400 cpm/μCi, compared to 4.4 × 104 cps/Bq (990 cpm/μCi for a conventional collimator system. The system resolution was 1.7 mm, as compared to 4–6 mm for the conventional imaging system (using a high-sensitivity low-energy collimator. Animal imaging demonstrated artifact-free imaging with superior resolution and image quality compared to conventional collimator images in several mouse and rat models. We conclude that: (a CA imaging is a useful nuclear imaging technique for small animal imaging. The advantage in signal-to-noise can be traded to achieve higher resolution, decreased dose or reduced imaging time. (b CA imaging works best for images where activity is concentrated in small volumes; a low count outline may be better demonstrated using conventional collimator imaging. Thus, CA imaging should be viewed as a technique to complement rather than replace traditional nuclear imaging methods. (c CA hardware and software can be readily adapted to existing gamma cameras, making their implementation a relatively inexpensive retrofit to most systems.

  1. Multimodality imaging of reporter gene expression using a novel fusion vector in living cells and animals

    Science.gov (United States)

    Gambhir, Sanjiv [Portola Valley, CA; Pritha, Ray [Mountain View, CA

    2011-06-07

    Novel double and triple fusion reporter gene constructs harboring distinct imagable reporter genes are provided, as well as applications for the use of such double and triple fusion constructs in living cells and in living animals using distinct imaging technologies.

  2. Live animal and meat export value chains for selected areas in Ethiopia: Constraints and opportunities for enhancing meat exports

    OpenAIRE

    Getachew, Legese; Hailemariam, Teklewold; Dawit, Alemu; Asfaw, Negassa

    2008-01-01

    The Ethiopian live animal and meat export marketing system is operating in an environment characterized by several constraints that needs the attention and action of the government and other non-governmental development organizations. Despite the reported high livestock population of the country, the major meat and live animal exporters are complaining of shortage of supply and inferior quality of animals (especially shoats). The problem could be because of the constraints in the marketing sy...

  3. UTIs in small animal patients: part 1: etiology and pathogenesis.

    Science.gov (United States)

    Smee, Nicole; Loyd, Kimberly; Grauer, Greg

    2013-01-01

    Understanding how urinary tract infections (UTIs) can occur and how to classify them can help the practitioner to make a plan for treatment. This review summarizes the etiology, pathogenesis, and host defense mechanisms associated with bacterial UTIs in dogs and cats. UTIs in Small Animal Patients: Part 2: Diagnosis, Treatment, and Complications will appear in the March/April 2013 issue of the Journal of the American Animal Hospital Association.

  4. Reciprocity in group-living animals: partner control versus partner choice.

    Science.gov (United States)

    Schino, Gabriele; Aureli, Filippo

    2017-05-01

    Reciprocity is probably the most debated of the evolutionary explanations for cooperation. Part of the confusion surrounding this debate stems from a failure to note that two different processes can result in reciprocity: partner control and partner choice. We suggest that the common observation that group-living animals direct their cooperative behaviours preferentially to those individuals from which they receive most cooperation is to be interpreted as the result of the sum of the two separate processes of partner control and partner choice. We review evidence that partner choice is the prevalent process in primates and propose explanations for this pattern. We make predictions that highlight the need for studies that separate the effects of partner control and partner choice in a broader variety of group-living taxa. © 2016 Cambridge Philosophical Society.

  5. Monte Carlo simulation of small field electron beams for small animal irradiation

    International Nuclear Information System (INIS)

    Lee, Chung-Chi; Chen, Ai-Mei; Tung, Chuan-Jong; Chao, Tsi-Chian

    2011-01-01

    The volume effect of detectors in the dosimetry of small fields for photon beams has been well studied due to interests in radiosurgery and small beamlets used in IMRT treatments; but there is still an unexplored research field for small electron beams used in small animal irradiation. This study proposes to use the BEAM Monte Carlo (MC) simulation to assess characteristics of small electron beams (4, 6, 14, 30 mm in diameter) with the kinetic energies of 6 and 18 MeV. Three factors influencing beam characteristics were studied (1) AE and ECUT settings, (2) photon jaw settings and (3) simulation pixel sizes. Study results reveal that AE/ECUT settings at 0.7 MeV are adequate for linear accelerator treatment head simulation, while 0.521 MeV is more favorable to be used for the phantom study. It is also demonstrated that voxel size setting at 1/4 of the simulation field width in all directions is sufficient to achieve accurate results. As for the photon jaw setting, it has great impact on the absolute output of different field size setting (i.e. output factor) but with minimum effect on the relative lateral distribution.

  6. Small-animal dark-field radiography for pulmonary emphysema evaluation

    Science.gov (United States)

    Yaroshenko, Andre; Meinel, Felix G.; Hellbach, Katharina; Bech, Martin; Velroyen, Astrid; Müller, Mark; Bamberg, Fabian; Nikolaou, Konstantin; Reiser, Maximilian F.; Yildirim, Ali Ã.-.; Eickelberg, Oliver; Pfeiffer, Franz

    2014-03-01

    Chronic obstructive pulmonary disease (COPD) is one of the leading causes of morbidity and mortality worldwide and emphysema is one of its main components. The disorder is characterized by irreversible destruction of the alveolar walls and enlargement of distal airspaces. Despite the severe changes in the lung tissue morphology, conventional chest radiographs have only a limited sensitivity for the detection of mild to moderate emphysema. X-ray dark-field is an imaging modality that can significantly increase the visibility of lung tissue on radiographic images. The dark-field signal is generated by coherent, small-angle scattering of x-rays on the air-tissue interfaces in the lung. Therefore, morphological changes in the lung can be clearly visualized on dark-field images. This is demonstrated by a preclinical study with a small-animal emphysema model. To generate a murine model of pulmonary emphysema, a female C57BL/6N mouse was treated with a single orotracheal application of porcine pancreatic elastase (80 U/kg body weight) dissolved in phosphate-buffered saline (PBS). Control mouse received PBS. The mice were imaged using a small-animal dark-field scanner. While conventional x-ray transmission radiography images revealed only subtle indirect signs of the pulmonary disorder, the difference between healthy and emphysematous lungs could be clearly directly visualized on the dark-field images. The dose applied to the animals is compatible with longitudinal studies. The imaging results correlate well with histology. The results of this study reveal the high potential of dark-field radiography for clinical lung imaging.

  7. Performance evaluation of a mouse-sized camera for dynamic studies in small animals

    International Nuclear Information System (INIS)

    Loudos, George; Majewski, Stan; Wojcik, Randy; Weisenberger, Andrew; Sakellios, Nicolas; Nikita, Konstantina; Uzunoglu, Nikolaos; Bouziotis, Penelope; Varvarigou, Alexandra

    2007-01-01

    A mouse sized camera has been built in terms of collaboration between the presenting institutions. The system is used for the performance of dynamic studies in small animals, in order to evaluate novel radiopharmaceuticals. The active area of the detector is approximately 48x96 mm allowing depiction of the entire mouse in a single view. The system is based on two flat-panel Hamamatsu H8500 position sensitive photomultiplier tubes (PSPMT), a pixellated NaI(Tl) scintillator and a copper-beryllium (CuBe) parallel-hole collimator. In this work, the evaluation results of the system are presented, using phantoms and small animals injected with conventional radiophrmaceuticals. Average resolution was ∼1.6 mm on the collimator surface and increased to ∼4.1 mm in 12 cm distance from the detector. The average energy resolution was measured and found to be ∼15.6% for Tc 99m . Results from imaging thin capillaries demonstrated system's high resolution and sensitivity in activity variations was shown. Initial dynamic studies have been carried out in small animals injected with Tc 99m -DTPA and Tc 99m -MDP. The results show system's ability to perform kinetic imaging in small animals

  8. Development of Optical Molecular Imaging System for the Acquisition of Bioluminescence Signals from Small Animals

    International Nuclear Information System (INIS)

    Lee, Byeong Il; Kim, Hyeon Sik; Jeong, Hye Jin; Lee, Hyung Jae; Moon, Seung Min; Kwon, Seung Young; Jeong, Shin Young; Bom, Hee Seung; Min, Jung Joon; Choi, Eun Seo

    2009-01-01

    Optical imaging is providing great advance and improvement in genetic and molecular imaging of animals and humans. Optical imaging system consists of optical imaging devices, which carry out major function for monitoring, tracing, and imaging in most of molecular in-vivo researches. In bio-luminescent imaging, small animals containing luciferase gene locally irradiate light, and emitted photons transmitted through skin of the small animals are imaged by using a high sensitive charged coupled device (CCD) camera. In this paper, we introduced optical imaging system for the image acquisition of bio-luminescent signals emitted from small animals. In the system, Nikon lens and four LED light sources were mounted at the inside of a dark box. A cooled CCD camera equipped with a control module was used. We tested the performance of the optical imaging system using effendorf tube and light emitting bacteria which injected intravenously into CT26 tumor bearing nude mouse. The performance of implemented optical imaging system for bio-luminescence imaging was demonstrated and the feasibility of the system in small animal imaging application was proved. We anticipate this system could be a useful tool for the molecular imaging of small animals adaptable for various experimental conditions in future

  9. Open-Source Medical Devices (OSMD) Design of a Small Animal Radiotherapy System

    Science.gov (United States)

    Prajapati, S.; Mackie, T. R.; Jeraj, R.

    2014-03-01

    Open-Source Medical Devices (OSMD) was initiated with the goal of facilitating medical research by developing medical technologies including both hardware and software on an open-source platform. Our first project was to develop an integrated imaging and radiotherapy device for small animals that includes computed tomography (CT), positron emission tomography (PET) and radiation therapy (RT) modalities for which technical specifications were defined in the first OSMD conference held in Madison, Wisconsin, USA in December 2011. This paper specifically focuses on the development of a small animal RT (micro-RT) system by designing a binary micro multileaf collimator (bmMLC) and a small animal treatment planning system (SATPS) to enable intensity modulated RT (IMRT). Both hardware and software projects are currently under development and their current progresses are described. After the development, both bmMLC and TPS will be validated and commissioned for a micro-RT system. Both hardware design and software development will be open-sourced after completion.

  10. [Application of paramunity inducers in small animal practice].

    Science.gov (United States)

    Proksch, A L; Hartmann, K

    2016-01-01

    Paramunity inducers have been used to treat small animals for decades. Paramunity inducers are based on attenuated and inactivated poxviruses (avipox virus and parapox virus). Their applications include both therapeutic and prophylactic use in various diseases. Despite their wide and variable use, only a very small number of placebo-controlled studies has been published. Positive effects in preventing kitten mortality and in treating feline stomatitis have been reported, however, no statistically significant effect of their therapeutic use in canine parvovirus infection, feline leukemia infection virus infection or canine papillomavirus infection could be demonstrated. For these infectious diseases, paramunity inducers do not appear to be effective.

  11. Recommendations on vaccination for Asian small animal practitioners: a report of the WSAVA Vaccination Guidelines Group.

    Science.gov (United States)

    Day, M J; Karkare, U; Schultz, R D; Squires, R; Tsujimoto, H

    2015-02-01

    In 2012 and 2013, the World Small Animal Veterinary Association (WSAVA) Vaccination Guidelines Group (VGG) undertook fact-finding visits to several Asian countries, with a view to developing advice for small companion animal practitioners in Asia related to the administration of vaccines to dogs and cats. The VGG met with numerous first opinion practitioners, small animal association leaders, academic veterinarians, government regulators and industry representatives and gathered further information from a survey of almost 700 veterinarians in India, China, Japan and Thailand. Although there were substantial differences in the nature and magnitude of the challenges faced by veterinarians in each country, and also differences in the resources available to meet those challenges, overall, the VGG identified insufficient undergraduate and postgraduate training in small companion animal microbiology, immunology and vaccinology. In most of the countries, there has been little academic research into small animal infectious diseases. This, coupled with insufficient laboratory diagnostic support, has limited the growth of knowledge concerning the prevalence and circulating strains of key infectious agents in most of the countries visited. Asian practitioners continue to recognise clinical infections that are now considered uncommon or rare in western countries. In particular, canine rabies virus infection poses a continuing threat to animal and human health in this region. Both nationally manufactured and international dog and cat vaccines are variably available in the Asian countries, but the product ranges are small and dominated by multi-component vaccines with a licensed duration of immunity (DOI) of only 1 year, or no description of DOI. Asian practitioners are largely unaware of current global trends in small animal vaccinology or of the WSAVA vaccination guidelines. Consequently, most practitioners continue to deliver annual revaccination with both core and non

  12. A high throughput live transparent animal bioassay to identify non-toxic small molecules or genes that regulate vertebrate fat metabolism for obesity drug development

    Directory of Open Access Journals (Sweden)

    Woollett Laura A

    2008-08-01

    Full Text Available Abstract Background The alarming rise in the obesity epidemic and growing concern for the pathologic consequences of the metabolic syndrome warrant great need for development of obesity-related pharmacotherapeutics. The search for such therapeutics is severely limited by the slow throughput of animal models of obesity. Amenable to placement into a 96 well plate, zebrafish larvae have emerged as one of the highest throughput vertebrate model organisms for performing small molecule screens. A method for visually identifying non-toxic molecular effectors of fat metabolism using a live transparent vertebrate was developed. Given that increased levels of nicotinamide adenine dinucleotide (NAD via deletion of CD38 have been shown to prevent high fat diet induced obesity in mice in a SIRT-1 dependent fashion we explored the possibility of directly applying NAD to zebrafish. Methods Zebrafish larvae were incubated with daily refreshing of nile red containing media starting from a developmental stage of equivalent fat content among siblings (3 days post-fertilization, dpf and continuing with daily refreshing until 7 dpf. Results PPAR activators, beta-adrenergic agonists, SIRT-1 activators, and nicotinic acid treatment all caused predicted changes in fat, cholesterol, and gene expression consistent with a high degree of evolutionary conservation of fat metabolism signal transduction extending from man to zebrafish larvae. All changes in fat content were visually quantifiable in a relative fashion using live zebrafish larvae nile red fluorescence microscopy. Resveratrol treatment caused the greatest and most consistent loss of fat content. The resveratrol tetramer Vaticanol B caused loss of fat equivalent in potency to resveratrol alone. Significantly, the direct administration of NAD decreased fat content in zebrafish. Results from knockdown of a zebrafish G-PCR ortholog previously determined to decrease fat content in C. elegans support that future GPR

  13. Theriocide: Naming Animal Killing

    Directory of Open Access Journals (Sweden)

    Piers Beirne

    2014-08-01

    Full Text Available In this essay I recommend ‘theriocide’ as the name for those diverse human actions that cause the deaths of animals. Like the killing of one human by another, theriocide may be socially acceptable or unacceptable, legal or illegal. It may be intentional or unintentional and may involve active maltreatment or passive neglect. Theriocide may occur one-on-one, in small groups or in large-scale social institutions. The numerous and sometimes intersecting sites of theriocide include intensive rearing regimes; hunting and fishing; trafficking; vivisection; militarism; pollution; and human-induced climate change. If the killing of animals by humans is as harmful to them as homicide is to humans, then the proper naming of such deaths offers a remedy, however small, to the extensive privileging of human lives over those of other animals. Inevitably, the essay leads to a shocking question: Is theriocide murder?

  14. Carriage of methicillin-resistant Staphylococcus pseudintermedius in small animal veterinarians

    DEFF Research Database (Denmark)

    Paul, Narayan Chandra; Moodley, Arshnee; Ghibaudo, G.

    2011-01-01

    Methicillin-resistant Staphylococcus pseudintermedius (MRSP) is increasingly reported in small animals and cases of human infections have already been described despite its recent emergence in veterinary practice. We investigated the prevalence of MRSP and methicillin-resistant Staphylococcus...... aureus (MRSA) among small animal dermatologists attending a national veterinary conference in Italy. Nasal swabs were obtained from 128 veterinarians, seven of which harboured MRSP (n = 5; 3.9%) or MRSA (n = 2; 1.6%). A follow-up study of two carriers revealed that MRSP persisted for at least 1 month...... by spa typing. Methicillin-resistant isolates were further typed by antimicrobial susceptibility testing, SCCmec and multi-locus sequence typing. Two lineages previously associated with pets were identified among the five MRSP isolates; the European epidemic clone ST71-SCCmec II-III and ST106-SCCmec IV...

  15. Multi-institutional MicroCT image comparison of image-guided small animal irradiators

    Science.gov (United States)

    Johnstone, Chris D.; Lindsay, Patricia; E Graves, Edward; Wong, Eugene; Perez, Jessica R.; Poirier, Yannick; Ben-Bouchta, Youssef; Kanesalingam, Thilakshan; Chen, Haijian; E Rubinstein, Ashley; Sheng, Ke; Bazalova-Carter, Magdalena

    2017-07-01

    To recommend imaging protocols and establish tolerance levels for microCT image quality assurance (QA) performed on conformal image-guided small animal irradiators. A fully automated QA software SAPA (small animal phantom analyzer) for image analysis of the commercial Shelley micro-CT MCTP 610 phantom was developed, in which quantitative analyses of CT number linearity, signal-to-noise ratio (SNR), uniformity and noise, geometric accuracy, spatial resolution by means of modulation transfer function (MTF), and CT contrast were performed. Phantom microCT scans from eleven institutions acquired with four image-guided small animal irradiator units (including the commercial PXi X-RAD SmART and Xstrahl SARRP systems) with varying parameters used for routine small animal imaging were analyzed. Multi-institutional data sets were compared using SAPA, based on which tolerance levels for each QA test were established and imaging protocols for QA were recommended. By analyzing microCT data from 11 institutions, we established image QA tolerance levels for all image quality tests. CT number linearity set to R 2  >  0.990 was acceptable in microCT data acquired at all but three institutions. Acceptable SNR  >  36 and noise levels  1.5 lp mm-1 for MTF  =  0.2) was obtained at all but four institutions due to their large image voxel size used (>0.275 mm). Ten of the eleven institutions passed the set QA tolerance for geometric accuracy (2000 HU for 30 mgI ml-1). We recommend performing imaging QA with 70 kVp, 1.5 mA, 120 s imaging time, 0.20 mm voxel size, and a frame rate of 5 fps for the PXi X-RAD SmART. For the Xstrahl SARRP, we recommend using 60 kVp, 1.0 mA, 240 s imaging time, 0.20 mm voxel size, and 6 fps. These imaging protocols should result in high quality images that pass the set tolerance levels on all systems. Average SAPA computation time for complete QA analysis for a 0.20 mm voxel, 400 slice Shelley phantom microCT data set

  16. Computer-aided pulmonary image analysis in small animal models

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Ziyue; Mansoor, Awais; Mollura, Daniel J. [Center for Infectious Disease Imaging (CIDI), Radiology and Imaging Sciences, National Institutes of Health (NIH), Bethesda, Maryland 32892 (United States); Bagci, Ulas, E-mail: ulasbagci@gmail.com [Center for Research in Computer Vision (CRCV), University of Central Florida (UCF), Orlando, Florida 32816 (United States); Kramer-Marek, Gabriela [The Institute of Cancer Research, London SW7 3RP (United Kingdom); Luna, Brian [Microfluidic Laboratory Automation, University of California-Irvine, Irvine, California 92697-2715 (United States); Kubler, Andre [Department of Medicine, Imperial College London, London SW7 2AZ (United Kingdom); Dey, Bappaditya; Jain, Sanjay [Center for Tuberculosis Research, Johns Hopkins University School of Medicine, Baltimore, Maryland 21231 (United States); Foster, Brent [Department of Biomedical Engineering, University of California-Davis, Davis, California 95817 (United States); Papadakis, Georgios Z. [Radiology and Imaging Sciences, National Institutes of Health (NIH), Bethesda, Maryland 32892 (United States); Camp, Jeremy V. [Department of Microbiology and Immunology, University of Louisville, Louisville, Kentucky 40202 (United States); Jonsson, Colleen B. [National Institute for Mathematical and Biological Synthesis, University of Tennessee, Knoxville, Tennessee 37996 (United States); Bishai, William R. [Howard Hughes Medical Institute, Chevy Chase, Maryland 20815 and Center for Tuberculosis Research, Johns Hopkins University School of Medicine, Baltimore, Maryland 21231 (United States); Udupa, Jayaram K. [Medical Image Processing Group, Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104 (United States)

    2015-07-15

    Purpose: To develop an automated pulmonary image analysis framework for infectious lung diseases in small animal models. Methods: The authors describe a novel pathological lung and airway segmentation method for small animals. The proposed framework includes identification of abnormal imaging patterns pertaining to infectious lung diseases. First, the authors’ system estimates an expected lung volume by utilizing a regression function between total lung capacity and approximated rib cage volume. A significant difference between the expected lung volume and the initial lung segmentation indicates the presence of severe pathology, and invokes a machine learning based abnormal imaging pattern detection system next. The final stage of the proposed framework is the automatic extraction of airway tree for which new affinity relationships within the fuzzy connectedness image segmentation framework are proposed by combining Hessian and gray-scale morphological reconstruction filters. Results: 133 CT scans were collected from four different studies encompassing a wide spectrum of pulmonary abnormalities pertaining to two commonly used small animal models (ferret and rabbit). Sensitivity and specificity were greater than 90% for pathological lung segmentation (average dice similarity coefficient > 0.9). While qualitative visual assessments of airway tree extraction were performed by the participating expert radiologists, for quantitative evaluation the authors validated the proposed airway extraction method by using publicly available EXACT’09 data set. Conclusions: The authors developed a comprehensive computer-aided pulmonary image analysis framework for preclinical research applications. The proposed framework consists of automatic pathological lung segmentation and accurate airway tree extraction. The framework has high sensitivity and specificity; therefore, it can contribute advances in preclinical research in pulmonary diseases.

  17. Heat stress: a major contributor to poor animal welfare associated with long-haul live export voyages.

    Science.gov (United States)

    Caulfield, Malcolm P; Cambridge, Heather; Foster, Susan F; McGreevy, Paul D

    2014-02-01

    Recent investigations by the Australian Department of Agriculture, Fisheries and Forestry into high mortalities on live export voyages from Australia to the Middle East during the Northern hemisphere summer suggest that animal welfare may be compromised by heat stress. The live export industry has generated a computer model that aims to assess the risk of heat stress and to contain mortality levels on live export ships below certain arbitrary limits. Although the model must be complied with under Australian law, it is not currently available for independent scientific scrutiny, and there is concern that model and the mandated space allowances are inadequate. This review appraises the relevant literature on heat stress in sheep and cattle, including laboratory studies aimed at mimicking the ambient temperatures and humidity levels likely to be encountered on live export voyages. Animal welfare is likely to be very poor as a result of heat stress in some shipments. Copyright © 2013 The Authors. Published by Elsevier Ltd.. All rights reserved.

  18. Comparison SPECT-CT with PET-CT in several applications of small-animal models

    International Nuclear Information System (INIS)

    Pan Yifan; Song Shaoli; Huang Gang

    2009-01-01

    With the development of medical science, monitoring dynamic biologic processes in small-animal models of diseases has become one of the most important approaches in medical studies. Important physiologic parameters that traditionally have been characterized by nuclear medicine imaging include blood flow, biochemical metabolism, and cellular receptors. Recently, nuclear medicine has been greatly facilitated by the newer development of dual-modality integrated imaging systems (SPECT-CT and PET-CT), which provide functional and anatomical images in the same scanning session, with the acquired images co-registered by means of the hardware. The purpose of this review is to compare SPECT-CT with PET-CT in several applications of small-animal models. Conclusicn: PET-CT for small animal modes in nledical research in the applications has great advantages, but SPECT-CT is still a very important role, and research low cost. (authors)

  19. The Effects of Collaborative Care of Living Animals in Biology Lessons on Students' Relatedness Toward Their Teacher Across Gender

    Science.gov (United States)

    Eckes, Alexander; Großmann, Nadine; Wilde, Matthias

    2018-01-01

    The transition from elementary school to the upper grades can lead to ambiguous feelings toward the new, male teachers. This study investigated whether collaborative animal care in biology lessons affects students' feelings of relatedness toward their biology teachers positively during the first year after the school transition. Four hundred twenty fifth graders (M age = 10.5 years, SD age = 0.6 years) of higher types of tracking participated. We designed one experimental group that involved caring for the living animals to be used in the upcoming lessons, and two control groups. The first control group included lessons with living animals, but did not include prior care of those animals, and the second incorporated neither living animals nor prior care. All groups received biology lessons with the same content. To examine the effects of caretaking, we used an adapted version of the scale "relatedness" (Ryan 1982). In both control groups, boys showed lower relatedness toward female teachers and girls toward male teachers, respectively. Collaborative mice care promoted equal relatedness across all gender combinations among teachers and students.

  20. Prototype design of singles processing unit for the small animal PET

    Science.gov (United States)

    Deng, P.; Zhao, L.; Lu, J.; Li, B.; Dong, R.; Liu, S.; An, Q.

    2018-05-01

    Position Emission Tomography (PET) is an advanced clinical diagnostic imaging technique for nuclear medicine. Small animal PET is increasingly used for studying the animal model of disease, new drugs and new therapies. A prototype of Singles Processing Unit (SPU) for a small animal PET system was designed to obtain the time, energy, and position information. The energy and position is actually calculated through high precison charge measurement, which is based on amplification, shaping, A/D conversion and area calculation in digital signal processing domian. Analysis and simulations were also conducted to optimize the key parameters in system design. Initial tests indicate that the charge and time precision is better than 3‰ FWHM and 350 ps FWHM respectively, while the position resolution is better than 3.5‰ FWHM. Commination tests of the SPU prototype with the PET detector indicate that the system time precision is better than 2.5 ns, while the flood map and energy spectra concored well with the expected.

  1. 9 CFR 71.17 - Interstate movement of dead poultry or other animals prohibited in same car with live poultry or...

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Interstate movement of dead poultry or other animals prohibited in same car with live poultry or other animals. 71.17 Section 71.17 Animals and... TRANSPORTATION OF ANIMALS (INCLUDING POULTRY) AND ANIMAL PRODUCTS GENERAL PROVISIONS § 71.17 Interstate movement...

  2. CS-137 in Austrian domestic animals: determination of transfer parameters and meat contamination by live animal measurements

    International Nuclear Information System (INIS)

    Henrich, E.

    1987-01-01

    Soon after the Chernobyl accident several programs were initiated by provincial and federal authorities to check the validity of transfer factors and biological lifetimes as given in the literature; to test the possibility of reducing the cesium content in meat and milk by chemical agents; and to determine the cesium content of meat in live animals to assist of slaughtering decisions. Details and results of these programs are presented. 1 tab., 3 figs., 9 refs. (qui)

  3. Current concepts in oncologic surgery in small animals.

    Science.gov (United States)

    Matz, Brad M

    2015-05-01

    Surgical oncology is experiencing rapid transition in veterinary medicine. Mast cell tumors and soft tissue sarcomas are two of the most common neoplasms in small animal patients. Clinicians should be familiar with the need for staging and the procedures involved in treating patients with these tumors. Clinicians should be comfortable with available adjuvant therapies and when to use them in certain patients. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Scalable Electrophysiology in Intact Small Animals with Nanoscale Suspended Electrode Arrays

    OpenAIRE

    Gonzales, Daniel L.; Badhiwala, Krishna N.; Vercosa, Daniel G.; Avants, Ben W.; Liu, Zheng; Zhong, Weiwei; Robinson, Jacob T.

    2017-01-01

    Electrical measurements from large populations of animals would help reveal fundamental properties of the nervous system and neurological diseases. Small invertebrates are ideal for these large-scale studies; however, patch-clamp electrophysiology in microscopic animals typically requires low-throughput and invasive dissections. To overcome these limitations, we present nano-SPEARs: suspended electrodes integrated into a scalable microfluidic device. Using this technology, we have made the fi...

  5. Light pollution disrupts sleep in free-living animals.

    Science.gov (United States)

    Raap, Thomas; Pinxten, Rianne; Eens, Marcel

    2015-09-04

    Artificial lighting can alter individual behaviour, with often drastic and potentially negative effects on biological rhythms, daily activity and reproduction. Whether this is caused by a disruption of sleep, an important widespread behaviour enabling animals to recover from daily stress, is unclear. We tested the hypothesis that light pollution disrupts sleep by recording individual sleep behaviour of great tits, Parus major, that were roosting in dark nest-boxes and were exposed to light-emitting diode light the following night. Their behaviour was compared to that of control birds sleeping in dark nest-boxes on both nights. Artificial lighting caused experimental birds to wake up earlier, sleep less (-5%) and spent less time in the nest-box as they left their nest-box earlier in the morning. Experimental birds did not enter the nest-box or fall asleep later than controls. Although individuals in lit nest-boxes did not wake up more often nor decreased the length of their sleep bouts, females spent a greater proportion of the night awake. Our study provides the first direct proof that light pollution has a significant impact on sleep in free-living animals, in particular in the morning, and highlights a mechanism for potential effects of light pollution on fitness.

  6. Partial body irradiation of small laboratory animals with an industrial X-ray tube

    International Nuclear Information System (INIS)

    Frenzel, Thorsten; Kruell, Andreas; Grohmann, Carsten; Schumacher, Udo

    2014-01-01

    Dedicated precise small laboratory animal irradiation sources are needed for basic cancer research and to meet this need expensive high precision radiation devices have been developed. To avoid such expenses a cost efficient way is presented to construct a device for partial body irradiation of small laboratory animals by adding specific components to an industrial X-ray tube. A custom made radiation field tube was added to an industrial 200 kV X-ray tube. A light field display as well as a monitor ionization chamber were implemented. The field size can rapidly be changed by individual inserts of MCP96 that are used for secondary collimation of the beam. Depth dose curves and cross sectional profiles were determined with the use of a custom made water phantom. More components like positioning lasers, a custom made treatment couch, and a commercial isoflurane anesthesia unit were added to complete the system. With the accessories described secondary small field sizes down to 10 by 10 mm 2 (secondary collimator size) could be achieved. The dosimetry of the beam was constructed like those for conventional stereotactical clinical linear accelerators. The water phantom created showed an accuracy of 1 mm and was well suited for all measurements. With the anesthesia unit attached to the custom made treatment couch the system is ideal for the radiation treatment of small laboratory animals like mice. It was feasible to shrink the field size of an industrial X-ray tube from whole animal irradiation to precise partial body irradiation of small laboratory animals. Even smaller secondary collimator sizes than 10 by 10 mm 2 are feasible with adequate secondary collimator inserts. Our custom made water phantom was well suited for the basic dosimetry of the X-ray tube.

  7. High-resolution emission tomography of small laboratory animals: physics and gamma-astronomy meet molecular biology

    International Nuclear Information System (INIS)

    Beekman, F.J.; Colijn, A.P.; Vastenhouw, B.; Wiegant, V.M.; Gerrits, M.A.F.M.

    2003-01-01

    Molecular imaging can be defined as the characterization and measurement of biological processes in living animals, model systems and humans at the cellular and molecular level using remote imaging detectors. An example concerns the mapping of the distributions of radioactively labeled molecules in laboratory animals which is of crucial importance for life sciences. Tomographic methods like Single Photon Emission Computed Tomography (SPECT) offer a possibility to visualize distributions of radioactively labeled molecules in living animals. Miniature tomography systems, derived from their clinical counterparts, but with a much higher image resolution are under development in several institutes. An example is U-SPECT that will be discussed in the present paper. Such systems are expected to accelerate several biomedical research procedures, the understanding of gene and protein function, as well as pharmaceutical development

  8. State of the art in both in vitro and in vivo aspects of small animal imaging

    International Nuclear Information System (INIS)

    Maziere, B.; Lebars, D.

    2002-01-01

    Full text: In vivo imaging for small animals is dramatically expanding due to the coincidence of mainly three technical factors: 1. the explosion in computer power 2. the enhancement in image processing 3. the accessibility and affordability of digital autoradiography systems and small-animal scanners. Among these imaging techniques let us mention the anatomical imaging techniques such as ultrasonography, X-rays and IRM and the functional imaging radioisotopic techniques SPECT and TEP. The main advantage of the first group of imaging techniques is essentially linked to the high resolution of the anatomical images (with the drawback of the necessity of putting the animal at rest using anaesthesia). The main advantages of SPECT and PET are their high sensitivity and the vast number of functions or metabolism they allow to image. The applications for isotopic functional imaging in small animals are increasing rapidly. Factors contributing to this dramatic expansion include the three previous technical factors plus, at least, three methodological factors: 1. the drug discovery process based on receptor / mechanism of action 2. the increasing number of rodent models of human diseases (SCID mice implanted with human tumors, gene knock-out mice, transgene mice) 3. the advances in isotope and validated tracer availability performances Small animal radioisotopic functional imaging for drug development. In vivo quantification of biological processes to measure the mechanism of action of a potential drug and its concentration at the site of action has become mandatory for developing a drug. Rational and efficient means of confirming mechanisms of action are required. For this purpose, PET and/or SPECT functional - biochemical - molecular imaging in small animals are tools of choice for economical reasons (in the domain of drug development, industry is suffering huge opportunity costs by failing to weed out non-performing new active substances until late phases II and III) and

  9. Statistics of Scientific Procedures on Living Animals 2014: A new format, and hopefully a new era of diminishing animal experimentation?

    Science.gov (United States)

    Hudson-Shore, Michelle

    2016-03-01

    The Annual Statistics of Scientific Procedures on Living Animals Great Britain 2014 reports a welcome decline in animal experimentation in the UK. However, caution has to be exercised when interpreting these most recent figures, due to the significant changes made to satisfy the requirements of Directive 2010/63/EU as to what information is reported and how it is reported. Comparisons to the figures and trends reported in previous years is difficult, so this paper focuses on the specifics of the current report, providing information on overall animal use and highlighting specific issues associated with genetically-altered animals, fish and primates. There is a detailed discussion of the extent of the changes, commenting on the benefits and disadvantages of the new format, in areas such as severity of procedures, legislation and techniques of special interest. It also considers the consequences of the changes on the effective monitoring of laboratory animal use, the openness and transparency regarding the impacts of animal use, and the implementation of Three Rs initiatives. In addition, suggestions for further improvements to the new format are made to the Home Office. 2016 FRAME.

  10. Small nucleoli are a cellular hallmark of longevity.

    Science.gov (United States)

    Tiku, Varnesh; Jain, Chirag; Raz, Yotam; Nakamura, Shuhei; Heestand, Bree; Liu, Wei; Späth, Martin; Suchiman, H Eka D; Müller, Roman-Ulrich; Slagboom, P Eline; Partridge, Linda; Antebi, Adam

    2016-08-30

    Animal lifespan is regulated by conserved metabolic signalling pathways and specific transcription factors, but whether these pathways affect common downstream mechanisms remains largely elusive. Here we show that NCL-1/TRIM2/Brat tumour suppressor extends lifespan and limits nucleolar size in the major C. elegans longevity pathways, as part of a convergent mechanism focused on the nucleolus. Long-lived animals representing distinct longevity pathways exhibit small nucleoli, and decreased expression of rRNA, ribosomal proteins, and the nucleolar protein fibrillarin, dependent on NCL-1. Knockdown of fibrillarin also reduces nucleolar size and extends lifespan. Among wildtype C. elegans, individual nucleolar size varies, but is highly predictive for longevity. Long-lived dietary restricted fruit flies and insulin-like-peptide mutants exhibit small nucleoli and fibrillarin expression, as do long-lived dietary restricted and IRS1 knockout mice. Furthermore, human muscle biopsies from individuals who underwent modest dietary restriction coupled with exercise also display small nucleoli. We suggest that small nucleoli are a cellular hallmark of longevity and metabolic health conserved across taxa.

  11. Fabrication of a small animal restraint for synchrotron biomedical imaging using a rapid prototyper

    International Nuclear Information System (INIS)

    Zhu Ying; Zhang Honglin; McCrea, Richard; Bewer, Brian; Wiebe, Sheldon; Nichol, Helen; Ryan, Christopher; Wysokinski, Tomasz; Chapman, Dean

    2007-01-01

    Biomedical research at synchrotron facilities may involve imaging live animals that must remain motionless for extended periods of time to obtain quality images. Even breathing movements reduce image quality but on the other hand excessive restraint of animals increases morbidity and mortality. We describe a humane animal restraint designed to eliminate head movements while promoting animal survival. This paper describes how an animal restraint that conforms to the shape of an animal's head was fabricated by a 3D prototyper. The method used to translate medical computed tomography (CT) data to a 3D stereolithography format is described and images of its use at the Canadian Light Source (CLS) are shown. This type of restraint holds great promise in improving image quality and repeatability while reducing stress on experimental animals

  12. The motivations and methodology for high-throughput PET imaging of small animals in cancer research

    Energy Technology Data Exchange (ETDEWEB)

    Aide, Nicolas [Francois Baclesse Cancer Centre, Nuclear Medicine Department, Caen Cedex (France); Caen University, BioTICLA team, EA 4656, IFR 146, Caen (France); Visser, Eric P. [Radboud University Nijmegen Medical Center, Nuclear Medicine Department, Nijmegen (Netherlands); Lheureux, Stephanie [Caen University, BioTICLA team, EA 4656, IFR 146, Caen (France); Francois Baclesse Cancer Centre, Clinical Research Unit, Caen (France); Heutte, Natacha [Francois Baclesse Cancer Centre, Clinical Research Unit, Caen (France); Szanda, Istvan [King' s College London, Division of Imaging Sciences and Biomedical Engineering, London (United Kingdom); Hicks, Rodney J. [Peter MacCallum Cancer Centre, Centre for Molecular Imaging, East Melbourne (Australia)

    2012-09-15

    Over the last decade, small-animal PET imaging has become a vital platform technology in cancer research. With the development of molecularly targeted therapies and drug combinations requiring evaluation of different schedules, the number of animals to be imaged within a PET experiment has increased. This paper describes experimental design requirements to reach statistical significance, based on the expected change in tracer uptake in treated animals as compared to the control group, the number of groups that will be imaged, and the expected intra-animal variability for a given tracer. We also review how high-throughput studies can be performed in dedicated small-animal PET, high-resolution clinical PET systems and planar positron imaging systems by imaging more than one animal simultaneously. Customized beds designed to image more than one animal in large-bore small-animal PET scanners are described. Physics issues related to the presence of several rodents within the field of view (i.e. deterioration of spatial resolution and sensitivity as the radial and the axial offsets increase, respectively, as well as a larger effect of attenuation and the number of scatter events), which can be assessed by using the NEMA NU 4 image quality phantom, are detailed. (orig.)

  13. High-resolution short-exposure small-animal laboratory x-ray phase-contrast tomography

    Science.gov (United States)

    Larsson, Daniel H.; Vågberg, William; Yaroshenko, Andre; Yildirim, Ali Önder; Hertz, Hans M.

    2016-12-01

    X-ray computed tomography of small animals and their organs is an essential tool in basic and preclinical biomedical research. In both phase-contrast and absorption tomography high spatial resolution and short exposure times are of key importance. However, the observable spatial resolutions and achievable exposure times are presently limited by system parameters rather than more fundamental constraints like, e.g., dose. Here we demonstrate laboratory tomography with few-ten μm spatial resolution and few-minute exposure time at an acceptable dose for small-animal imaging, both with absorption contrast and phase contrast. The method relies on a magnifying imaging scheme in combination with a high-power small-spot liquid-metal-jet electron-impact source. The tomographic imaging is demonstrated on intact mouse, phantoms and excised lungs, both healthy and with pulmonary emphysema.

  14. Renaissance of morphological studies: the examination of functional structures in living animal organs using the in vivo cryotechnique.

    Science.gov (United States)

    Ohno, Shinichi; Saitoh, Yurika; Ohno, Nobuhiko; Terada, Nobuo

    2017-01-01

    Medical and biological scientists wish to understand the in vivo structures of the cells and tissues that make up living animal organs, as well as the locations of their molecular components. Recently, the live imaging of animal cells and tissues with fluorescence-labeled proteins produced via gene manipulation has become increasingly common. Therefore, it is important to ensure that findings derived from histological or immunohistochemical tissue sections of living animal organs are compatible with those obtained from live images of the same organs, which can be assessed using recently developed digital imaging techniques. Over the past two decades, we have performed immunohistochemical and morphological studies of the cells and tissues in living animal organs using a novel in vivo cryotechnique. The use of a specially designed liquid cryogen system with or without a cryoknife during this cryotechnique solved the technical problems that inevitably arise during the conventional preparation methods employed prior to light or electron microscopic examinations. Our in vivo cryotechnique has been found to be extremely useful for arresting transient physiological processes in cells and tissues and for maintaining their functional components-such as rapidly changing signaling molecules, membrane channels, or receptors-in situ. The purpose of the present review is to describe the basic mechanism underlying cryotechniques and the significance of our in vivo cryotechnique. In addition, it describes various morphological or immunohistochemical findings, observations made using quantum dots, and a Raman cryomicroscopy-based method for assessing oxygen saturation in the erythrocytes flowing through intestinal tissues.

  15. Development of in-vivo micro CT system for small animals

    Energy Technology Data Exchange (ETDEWEB)

    Nam, Ki Yong; Lim, Jong Hyeok; Jeong, Young Jo; Park, Jeong Gwon [Institute for Radiological Imaging Science, Iksan (Korea, Republic of); Park, Jung Bung [DRGEM Corp., Seoul (Korea, Republic of); Yoon, Kwon Ha [Institute for Radiological Imaging Science and Medical School of Radiology, Iksan (Korea, Republic of)

    2005-07-01

    Computed tomography system with the spatial resolution of {approx}25 {mu}m has been developed for the application to small animals. This system is designed by gantry-rotation type for minimizing animal movement. To get image with micro-spatial resolution, system characteristic such as geometry between main components of source, specimen and detector, field of view, etc., is described in this paper. The requirements of x-ray spot size and CCD pixel size to approach the resolution are discussed. In-vivo imaging test for mouse is also presented as a result.

  16. Development of in-vivo micro CT system for small animals

    International Nuclear Information System (INIS)

    Nam, Ki Yong; Lim, Jong Hyeok; Jeong, Young Jo; Park, Jeong Gwon; Park, Jung Bung; Yoon, Kwon Ha

    2005-01-01

    Computed tomography system with the spatial resolution of ∼25 μm has been developed for the application to small animals. This system is designed by gantry-rotation type for minimizing animal movement. To get image with micro-spatial resolution, system characteristic such as geometry between main components of source, specimen and detector, field of view, etc., is described in this paper. The requirements of x-ray spot size and CCD pixel size to approach the resolution are discussed. In-vivo imaging test for mouse is also presented as a result

  17. Small Molecule-Photoactive Yellow Protein Labeling Technology in Live Cell Imaging

    Directory of Open Access Journals (Sweden)

    Feng Gao

    2016-08-01

    Full Text Available Characterization of the chemical environment, movement, trafficking and interactions of proteins in live cells is essential to understanding their functions. Labeling protein with functional molecules is a widely used approach in protein research to elucidate the protein location and functions both in vitro and in live cells or in vivo. A peptide or a protein tag fused to the protein of interest and provides the opportunities for an attachment of small molecule probes or other fluorophore to image the dynamics of protein localization. Here we reviewed the recent development of no-wash small molecular probes for photoactive yellow protein (PYP-tag, by the means of utilizing a quenching mechanism based on the intramolecular interactions, or an environmental-sensitive fluorophore. Several fluorogenic probes have been developed, with fast labeling kinetics and cell permeability. This technology allows quick live-cell imaging of cell-surface and intracellular proteins without a wash-out procedure.

  18. Accessories for detention and protection used in small animals radiation therapy

    International Nuclear Information System (INIS)

    Vettorato, Michel Campos; Vulcano, Luiz Carlos; Fernandes, Marco Antonio Rodrigues

    2016-01-01

    Radiation therapy is a medical method well established in the treatment of cancer in veterinary medicine worldwide. The radiotherapy protocols applied in animals vary according to several factors. In most procedures require sedation or anesthesia of the animal and this fact imposes the use of immobilization accessories specially developed for the different species of animals and treated as their specified procedures. Therefore, this study aims to describe the types of accessories used for immobilization and for the protection of small animals undergoing radiotherapy. For its development a literature search was performed by search sites like Google Scholar, Scielo, Bireme, PubMed, and consultations in books campus library Botucatu UNESP. Despite the limitations of each accessory rated this review, it was possible to identify the use of each and how this can be advantageous for the treatment of animals undergoing radiation therapy. (author)

  19. Computed tomography of the central nervous system in small animals

    International Nuclear Information System (INIS)

    Tipold, A.; Tipold, E.

    1991-01-01

    With computed tomography in 44 small animals some well defined anatomical structures and pathological processes of the central nervous system are described. Computed tomography is not only necessary for the diagnosis of tumors; malformations, inflammatory, degenerative and vascular diseases and traumas are also visible

  20. Experience with a small animal hyperthermia ultrasound system (SAHUS): report on 83 tumours

    International Nuclear Information System (INIS)

    Novak, P; Moros, E G; Parry, J J; Rogers, B E; Myerson, R J; Zeug, A; Locke, J E; Rossin, R; Straube, W L; Singh, A K

    2005-01-01

    An external local ultrasound (US) system was developed to induce controlled hyperthermia of subcutaneously implanted tumours in small animals (e.g., mice and rats). It was designed to be compatible with a small animal positron emission tomography scanner (microPET) to facilitate studies of hyperthermia-induced tumour re-oxygenation using a PET radiopharmaceutical, but it is applicable for any small animal study requiring controlled heating. The system consists of an acrylic applicator bed with up to four independent 5 MHz planar disc US transducers of 1 cm in diameter, a four-channel radiofrequency (RF) generator, a multiple thermocouple thermometry unit, and a personal computer with custom monitoring and controlling software. Although the system presented here was developed to target tumours of up to 1 cm in diameter, the applicator design allows for different piezoelectric transducers to be exchanged and operated within the 3.5-6.5 MHz band to target different tumour sizes. Temperature feedback control software was developed on the basis of a proportional-integral-derivative (PID) approach when the measured temperatures were within a selectable temperature band about the target temperature. Outside this band, an on/off control action was applied. Perfused tissue-mimicking phantom experiments were performed to determine optimum controller gain constants, which were later employed successfully in animal experiments. The performance of the SAHUS (small animal hyperthermia ultrasound system) was tested using several tumour types grown in thighs of female nude (nu/nu) mice. To date, the system has successfully treated 83 tumours to target temperatures in the range of 41-43 deg. C for periods of 65 min on average

  1. Design of a multimodal fibers optic system for small animal optical imaging.

    Science.gov (United States)

    Spinelli, Antonello E; Pagliazzi, Marco; Boschi, Federico

    2015-02-01

    Small animals optical imaging systems are widely used in pre-clinical research to image in vivo the bio-distribution of light emitting probes using fluorescence or bioluminescence modalities. In this work we presented a set of simulated results of a novel small animal optical imaging module based on a fibers optics matrix, coupled with a position sensitive detector, devoted to acquire bioluminescence and Cerenkov images. Simulations were performed using GEANT 4 code with the GAMOS architecture using the tissue optics plugin. Results showed that it is possible to image a 30 × 30 mm region of interest using a fiber optics array containing 100 optical fibers without compromising the quality of the reconstruction. The number of fibers necessary to cover an adequate portion of a small animal is thus quite modest. This design allows integrating the module with magnetic resonance (MR) in order to acquire optical and MR images at the same time. A detailed model of the mouse anatomy, obtained by segmentation of 3D MRI images, will improve the quality of optical 3D reconstruction. Copyright © 2014 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  2. Preliminary Experience with Small Animal SPECT Imaging on Clinical Gamma Cameras

    Directory of Open Access Journals (Sweden)

    P. Aguiar

    2014-01-01

    Full Text Available The traditional lack of techniques suitable for in vivo imaging has induced a great interest in molecular imaging for preclinical research. Nevertheless, its use spreads slowly due to the difficulties in justifying the high cost of the current dedicated preclinical scanners. An alternative for lowering the costs is to repurpose old clinical gamma cameras to be used for preclinical imaging. In this paper we assess the performance of a portable device, that is, working coupled to a single-head clinical gamma camera, and we present our preliminary experience in several small animal applications. Our findings, based on phantom experiments and animal studies, provided an image quality, in terms of contrast-noise trade-off, comparable to dedicated preclinical pinhole-based scanners. We feel that our portable device offers an opportunity for recycling the widespread availability of clinical gamma cameras in nuclear medicine departments to be used in small animal SPECT imaging and we hope that it can contribute to spreading the use of preclinical imaging within institutions on tight budgets.

  3. Simulation of time curves in small animal PET using GATE

    International Nuclear Information System (INIS)

    Simon, Luc; Strul, Daniel; Santin, Giovanni; Krieguer, Magalie; Morel, Christian

    2004-01-01

    The ClearPET project of the Crystal Clear Collaboration (CCC) is building spin-off technology for high resolution small animal Positron Emission Tomography (PET). Monte Carlo simulation is essential for optimizing the specifications of these systems with regards to their most important characteristics, such as spatial resolution, sensitivity, or count rate performance. GATE, the Geant4 Application for Tomographic Emission simulates the passing of time during real acquisitions, allowing to handle dynamic systems such as decaying source distributions or moving detectors. GATE output is analyzed on an event-by-event basis. The time associated with each single event allows to sort coincidences and to model dead-time. This leads to the study of time curves for a prospective small animal PET scanner design. The count rates of true, and random coincidences are discussed together with the corresponding Noise Equivalent Count (NEC) rates as a function of some PET scanner specifications such as detector dead time, or coincidence time window

  4. Characterization of a high-purity germanium detector for small-animal SPECT.

    Science.gov (United States)

    Johnson, Lindsay C; Campbell, Desmond L; Hull, Ethan L; Peterson, Todd E

    2011-09-21

    We present an initial evaluation of a mechanically cooled, high-purity germanium double-sided strip detector as a potential gamma camera for small-animal SPECT. It is 90 mm in diameter and 10 mm thick with two sets of 16 orthogonal strips that have a 4.5 mm width with a 5 mm pitch. We found an energy resolution of 0.96% at 140 keV, an intrinsic efficiency of 43.3% at 122 keV and a FWHM spatial resolution of approximately 1.5 mm. We demonstrated depth-of-interaction estimation capability through comparison of pinhole acquisitions with a point source on and off axes. Finally, a flood-corrected flood image exhibited a strip-level uniformity of less than 1%. This high-purity germanium offers many desirable properties for small-animal SPECT.

  5. Updating Animal Welfare Thinking: Moving beyond the "Five Freedoms" towards "A Life Worth Living".

    Science.gov (United States)

    Mellor, David J

    2016-03-14

    behaviours they find rewarding. These behaviours may include environment-focused exploration and food acquisition activities as well as animal-to-animal interactive activities, all of which can generate various forms of comfort, pleasure, interest, confidence and a sense of control. Animal welfare management should aim to reduce the intensity of survival-critical negative affects to tolerable levels that nevertheless still elicit the required behaviours, and should also provide opportunities for animals to behave in ways they find rewarding, noting that poor management of survival-critical affects reduces animals' motivation to utilize such rewarding opportunities. This biologically more accurate understanding provides support for reviewing the adequacy of provisions in current codes of welfare or practice in order to ensure that animals are given greater opportunities to experience positive welfare states. The purpose is to help animals to have lives worth living, which is not possible when the predominant focus of such codes is on survival-critical measures. Finally, an updated characterisation of animal welfare that incorporates this more accurate understanding is presented.

  6. Development of a Magnetoencephalograph System for Small Animals

    International Nuclear Information System (INIS)

    Kim, J. E.; Kim, I. S.; Kang, C. S.; Kwon, H.; Kim, J. M.; Lee, Y. H.; Kim, K.

    2011-01-01

    We developed a four-channel first order gradiometer system to measure magnetoencephalogram for mice. We used double relaxation oscillation SQUID (DROS). The diameter of the pickup coil is 4 mm and the distance between the coils is 5 mm. Coil distance was designed to have good spatial resolution for a small mouse brain. We evaluated the current dipole localization confidence region for a mouse brain, using the spherical conductor model. The white noise of the measurement system was about 30 fT/Hz 1/2 /cm when measured in a magnetically shielded room. We measured magnetic signal from a phantom having the same size of a mouse brain, which was filled with 0.9% saline solution. The results suggest that the developed system has a feasibility to study the functions of brain of small animals.

  7. Living with a diagnosis of non-small cell lung cancer: patients' lived experiences.

    LENUS (Irish Health Repository)

    McCarthy, Ita

    2012-01-31

    The aim of this study was to explore patients\\' experience of living with non-small cell lung cancer (NSCLC). Patients diagnosed with NSCLC know that their treatment is not with curative intent and can expect distressing symptoms. In this phenomenological study, six adults with a diagnosis of NSCLC were interviewed. Data was analysed guided by van Manen\\'s six-step process. Four main themes were interpreted: \\'Maintaining my life\\'; \\'The enemy within\\'; \\'Staying on the train\\

  8. Improvement of semi-quantitative small-animal PET data with recovery coefficients: a phantom and rat study.

    Science.gov (United States)

    Aide, Nicolas; Louis, Marie-Hélène; Dutoit, Soizic; Labiche, Alexandre; Lemoisson, Edwige; Briand, Mélanie; Nataf, Valérie; Poulain, Laurent; Gauduchon, Pascal; Talbot, Jean-Noël; Montravers, Françoise

    2007-10-01

    To evaluate the accuracy of semi-quantitative small-animal PET data, uncorrected for attenuation, and then of the same semi-quantitative data corrected by means of recovery coefficients (RCs) based on phantom studies. A phantom containing six fillable spheres (diameter range: 4.4-14 mm) was filled with an 18F-FDG solution (spheres/background activity=10.1, 5.1 and 2.5). RCs, defined as measured activity/expected activity, were calculated. Nude rats harbouring tumours (n=50) were imaged after injection of 18F-FDG and sacrificed. The standardized uptake value (SUV) in tumours was determined with small-animal PET and compared to ex-vivo counting (ex-vivo SUV). Small-animal PET SUVs were corrected with RCs based on the greatest tumour diameter. Tumour proliferation was assessed with cyclin A immunostaining and correlated to the SUV. RCs ranged from 0.33 for the smallest sphere to 0.72 for the largest. A sigmoidal correlation was found between RCs and sphere diameters (r(2)=0.99). Small-animal PET SUVs were well correlated with ex-vivo SUVs (y=0.48x-0.2; r(2)=0.71) and the use of RCs based on the greatest tumour diameter significantly improved regression (y=0.84x-0.81; r(2)=0.77), except for tumours with important necrosis. Similar results were obtained without sacrificing animals, by using PET images to estimate tumour dimensions. RC-based corrections improved correlation between small-animal PET SUVs and tumour proliferation (uncorrected data: Rho=0.79; corrected data: Rho=0.83). Recovery correction significantly improves both accuracy of small-animal PET semi-quantitative data in rat studies and their correlation with tumour proliferation, except for largely necrotic tumours.

  9. Living Animals in the Classroom: A Meta-Analysis on Learning Outcome and a Treatment-Control Study Focusing on Knowledge and Motivation

    Science.gov (United States)

    Hummel, Eberhard; Randler, Christoph

    2012-01-01

    Prior research states that the use of living animals in the classroom leads to a higher knowledge but those previous studies have methodological and statistical problems. We applied a meta-analysis and developed a treatment-control study in a middle school classroom. The treatments (film vs. living animal) differed only by the presence of the…

  10. The Ethical Egoist Case for Dietary Veganism, Or The Individual Animal and His Will to Live

    OpenAIRE

    Hansen, Bo-Nikolai Gjerpen

    2017-01-01

    Master's thesis religion - University of Agder 2017 In this thesis in applied ethics, «The ethical egoist case for dietary veganism, or the individual animal and his will to live», I argue that taking non-human animals into consideration can be argued for from an approach of ethical egoism. I argue that from the standpoint of egoism, in most cases you would be well advised to adopt a vegan diet, that means, practically speaking, a diet rid of animal products. The thesis is divided into ...

  11. Mating in the Closest Living Relatives of Animals Is Induced by a Bacterial Chondroitinase.

    Science.gov (United States)

    Woznica, Arielle; Gerdt, Joseph P; Hulett, Ryan E; Clardy, Jon; King, Nicole

    2017-09-07

    We serendipitously discovered that the marine bacterium Vibrio fischeri induces sexual reproduction in one of the closest living relatives of animals, the choanoflagellate Salpingoeca rosetta. Although bacteria influence everything from nutrition and metabolism to cell biology and development in eukaryotes, bacterial regulation of eukaryotic mating was unexpected. Here, we show that a single V. fischeri protein, the previously uncharacterized EroS, fully recapitulates the aphrodisiac-like activity of live V. fischeri. EroS is a chondroitin lyase; although its substrate, chondroitin sulfate, was previously thought to be an animal synapomorphy, we demonstrate that S. rosetta produces chondroitin sulfate and thus extend the ancestry of this important glycosaminoglycan to the premetazoan era. Finally, we show that V. fischeri, purified EroS, and other bacterial chondroitin lyases induce S. rosetta mating at environmentally relevant concentrations, suggesting that bacteria likely regulate choanoflagellate mating in nature. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Geo-PET: A novel generic organ-pet for small animal organs and tissues

    Science.gov (United States)

    Sensoy, Levent

    Reconstructed tomographic image resolution of small animal PET imaging systems is improving with advances in radiation detector development. However the trend towards higher resolution systems has come with an increase in price and system complexity. Recent developments in the area of solid-state photomultiplication devices like silicon photomultiplier arrays (SPMA) are creating opportunities for new high performance tools for PET scanner design. Imaging of excised small animal organs and tissues has been used as part of post-mortem studies in order to gain detailed, high-resolution anatomical information on sacrificed animals. However, this kind of ex-vivo specimen imaging has largely been limited to ultra-high resolution muCT. The inherent limitations to PET resolution have, to date, excluded PET imaging from these ex-vivo imaging studies. In this work, we leverage the diminishing physical size of current generation SPMA designs to create a very small, simple, and high-resolution prototype detector system targeting ex-vivo tomographic imaging of small animal organs and tissues. We investigate sensitivity, spatial resolution, and the reconstructed image quality of a prototype small animal PET scanner designed specifically for imaging of excised murine tissue and organs. We aim to demonstrate that a cost-effective silicon photomultiplier (SiPM) array based design with thin crystals (2 mm) to minimize depth of interaction errors might be able to achieve sub-millimeter resolution. We hypothesize that the substantial decrease in sensitivity associated with the thin crystals can be compensated for with increased solid angle detection, longer acquisitions, higher activity and wider acceptance energy windows (due to minimal scatter from excised organs). The constructed system has a functional field of view (FoV) of 40 mm diameter, which is adequate for most small animal specimen studies. We perform both analytical (3D-FBP) and iterative (ML-EM) methods in order to

  13. Control of positive end-expiratory pressure (PEEP for small animal ventilators

    Directory of Open Access Journals (Sweden)

    Leão Nunes Marcelo V

    2010-07-01

    Full Text Available Abstract Background The positive end-expiratory pressure (PEEP for the mechanical ventilation of small animals is frequently obtained with water seals or by using ventilators developed for human use. An alternative mechanism is the use of an on-off expiratory valve closing at the moment when the alveolar pressure is equal to the target PEEP. In this paper, a novel PEEP controller (PEEP-new and the PEEP system of a commercial small-animal ventilator, both based on switching an on-off valve, are evaluated. Methods The proposed PEEP controller is a discrete integrator monitoring the error between the target PEEP and the airways opening pressure prior to the onset of an inspiratory cycle. In vitro as well as in vivo experiments with rats were carried out and the PEEP accuracy, settling time and under/overshoot were considered as a measure of performance. Results The commercial PEEP controller did not pass the tests since it ignores the airways resistive pressure drop, resulting in a PEEP 5 cmH2O greater than the target in most conditions. The PEEP-new presented steady-state errors smaller than 0.5 cmH2O, with settling times below 10 s and under/overshoot smaller than 2 cmH2O. Conclusion The PEEP-new presented acceptable performance, considering accuracy and temporal response. This novel PEEP generator may prove useful in many applications for small animal ventilators.

  14. Coil concepts for rapid and motion-compensated MR-Imaging of small animals

    International Nuclear Information System (INIS)

    Korn, Matthias

    2009-01-01

    In this work radiofrequency-coils for the imaging of small animals in clinical whole-body MRI-systems were developed. Therefore in a first step single-channel solenoids were designed and characterized. The solenoids had two and three windings respectively, which were implemented as double wires to increase the homogeneity of the receive profile. These coils allow the acquisition of whole-body images of mice with high signal-to-noise ratio and homogeneity over a distance of at least 6.3 cm. Since many imaging experiments require rapid image acquisition, in the next step a novel coil concept was developed, which, due to its geometry, enables parallel imaging in arbitrary directions. A prototype was assembled and tested on phantom and small-animal experiments. With an accelerating factor of R=2, the difference of the SNR in all directions from the theoretical maximum, was less than 1%. In order to compensate physiological motion by the self-gating technique, in this work a coil is presented for the first time, which selectively amplifies the self-gating signal, while - due to a optical detuning technique - preserving the homogeneous illumination of the image. In vivo experiments on a small animal show an amplification of the self-gating signal by at least 40%. (orig.)

  15. Enclosure for small animals during awake animal imaging

    Science.gov (United States)

    Goddard, Jr., James S

    2013-11-26

    An enclosure or burrow restrains an awake animal during an imaging procedure. A tubular body, made from a radiolucent material that does not attenuate x-rays or gamma rays, accepts an awake animal. A proximal end of the body includes an attachment surface that corresponds to an attachment surface of an optically transparent and optically uniform window. An anti-reflective coating may be applied to an inner surface, an outer surface, or both surfaces of the window. Since the window is a separate element of the enclosure and it is not integrally formed as part of the body, it can be made with optically uniform thickness properties for improved motion tracking of markers on the animal with a camera during the imaging procedure. The motion tracking information is then used to compensate for animal movement in the image.

  16. The bacteriology of the small intestinal mucosa of free-living reindeer

    Directory of Open Access Journals (Sweden)

    Wenche Sørmo

    1994-12-01

    Full Text Available Bacteria in close associaton with the intestinal mucosa are thought to protect the mucosa from pathogenic microorganisms. The pH of the small intestinal mucosa and the viable populations of aerobic and anaerobic bacteria associated with the proximal and distal jejunal mucosa, were measured in four free-living reindeer in winter. The anaerobic bacterial populations were characterized. The median pH of the mucosa of the duodenum was 6.6 (n=4 at point 0.2 m from the pyloric sphincter. The mucosal pH increased along the length of the intestine to 8.3 at 14 m and then decreased to 7.9 at 19.8 m from the pyloric sphincter. Examination by transmission electron microscopy and cultivation techniques failed to reveal any bacteria on the mucosa of the proximal jejunum in two of the animals. In two other reindeer the median anaerobic bacterial densities in the proximal jejunum ranged from 25-2500 cells/g mucosa. The median anaerobic bacterial populations in the distal jejunum ranged from 80 to 20000 bacteria/g mucosa (n=4. The anaerobic population of bacteria in the proximal jejunum was dominated by streptococci and unidentified gram positive rods. Bacteroidaceae, streptococci and unidentified gram positive rods were common in the distal jejunum. The low density and the species diversity of bacteria in the small intestine suggests that these microorganisms are inhibited by components in the natural winter diet of reindeer. Bacteria evidently play a minor role in protection of the mucosa of reindeer in winter.

  17. Importance of Attenuation Correction (AC) for Small Animal PET Imaging

    DEFF Research Database (Denmark)

    El Ali, Henrik H.; Bodholdt, Rasmus Poul; Jørgensen, Jesper Tranekjær

    2012-01-01

    was performed. Methods: Ten NMRI nude mice with subcutaneous implantation of human breast cancer cells (MCF-7) were scanned consecutively in small animal PET and CT scanners (MicroPETTM Focus 120 and ImTek’s MicroCATTM II). CT-based AC, PET-based AC and uniform AC methods were compared. Results: The activity...

  18. Monitoring of small laboratory animal experiments by a designated web-based database.

    Science.gov (United States)

    Frenzel, T; Grohmann, C; Schumacher, U; Krüll, A

    2015-10-01

    Multiple-parametric small animal experiments require, by their very nature, a sufficient number of animals which may need to be large to obtain statistically significant results.(1) For this reason database-related systems are required to collect the experimental data as well as to support the later (re-) analysis of the information gained during the experiments. In particular, the monitoring of animal welfare is simplified by the inclusion of warning signals (for instance, loss in body weight >20%). Digital patient charts have been developed for human patients but are usually not able to fulfill the specific needs of animal experimentation. To address this problem a unique web-based monitoring system using standard MySQL, PHP, and nginx has been created. PHP was used to create the HTML-based user interface and outputs in a variety of proprietary file formats, namely portable document format (PDF) or spreadsheet files. This article demonstrates its fundamental features and the easy and secure access it offers to the data from any place using a web browser. This information will help other researchers create their own individual databases in a similar way. The use of QR-codes plays an important role for stress-free use of the database. We demonstrate a way to easily identify all animals and samples and data collected during the experiments. Specific ways to record animal irradiations and chemotherapy applications are shown. This new analysis tool allows the effective and detailed analysis of huge amounts of data collected through small animal experiments. It supports proper statistical evaluation of the data and provides excellent retrievable data storage. © The Author(s) 2015.

  19. Development of a Magnetoencephalograph System for Small Animals

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J. E.; Kim, I. S.; Kang, C. S.; Kwon, H.; Kim, J. M.; Lee, Y. H.; Kim, K. [Brain and Cognition Measurement Laboratory, Korea Research Institute of Standards and Science(KRISS), Daejeon (Korea, Republic of)

    2011-08-15

    We developed a four-channel first order gradiometer system to measure magnetoencephalogram for mice. We used double relaxation oscillation SQUID (DROS). The diameter of the pickup coil is 4 mm and the distance between the coils is 5 mm. Coil distance was designed to have good spatial resolution for a small mouse brain. We evaluated the current dipole localization confidence region for a mouse brain, using the spherical conductor model. The white noise of the measurement system was about 30 fT/Hz{sup 1/2}/cm when measured in a magnetically shielded room. We measured magnetic signal from a phantom having the same size of a mouse brain, which was filled with 0.9% saline solution. The results suggest that the developed system has a feasibility to study the functions of brain of small animals.

  20. Potential arsenic exposures in 25 species of zoo animals living in CCA-wood enclosures

    International Nuclear Information System (INIS)

    Gress, J.; Silva, E.B. da; Oliveira, L.M. de; Zhao, Di; Anderson, G.; Heard, D.; Stuchal, L.D.; Ma, L.Q.

    2016-01-01

    Animal enclosures are often constructed from wood treated with the pesticide chromated copper arsenate (CCA), which leaches arsenic (As) into adjacent soil during normal weathering. This study evaluated potential pathways of As exposure in 25 species of zoo animals living in CCA-wood enclosures. We analyzed As speciation in complete animal foods, dislodgeable As from CCA-wood, and As levels in enclosure soils, as well as As levels in biomarkers of 9 species of crocodilians (eggs), 4 species of birds (feathers), 1 primate species (hair), and 1 porcupine species (quills). Elevated soil As in samples from 17 enclosures was observed at 1.0–110 mg/kg, and enclosures housing threatened and endangered species had As levels higher than USEPA's risk-based Eco-SSL for birds and mammals of 43 and 46 mg/kg. Wipe samples of CCA-wood on which primates sit had dislodgeable As residues of 4.6–111 μg/100 cm 2 , typical of unsealed CCA-wood. Inorganic As doses from animal foods were estimated at 0.22–7.8 μg/kg bw/d. Some As levels in bird feathers and crocodilian eggs were higher than prior studies on wild species. However, hair from marmosets had 6.37 mg/kg As, 30-fold greater than the reference value, possibly due to their inability to methylate inorganic As. Our data suggested that elevated As in soils and dislodgeable As from CCA-wood could be important sources of As exposure for zoo animals. - Highlights: • Daily inorganic As dose from zoo animal foods was 0.22–7.8 μg/kg bw/day. • Total As concentrations in soils of zoo animal enclosures were 1.0–110 mg/kg. • Endangered zoo animals live in soils with As above USEPA Eco-SSLs for avian and mammal species. • Dislodgeable As on CCA-wood beams where primates sit was 4.6–111 μg/100 cm 2 . • Marmoset hair had 6.37 mg/kg As compared to a reference value of 0.21 mg/kg.

  1. Potential arsenic exposures in 25 species of zoo animals living in CCA-wood enclosures

    Energy Technology Data Exchange (ETDEWEB)

    Gress, J. [State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Jiangsu 201146 (China); Soil and Water Science Department, University of Florida, Gainesville, FL 32611 (United States); Silva, E.B. da; Oliveira, L.M. de [Soil and Water Science Department, University of Florida, Gainesville, FL 32611 (United States); Zhao, Di [State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Jiangsu 201146 (China); Anderson, G. [Virginia Polytechnic Institute and State University, Blacksburg, VA 24061 (United States); Heard, D. [Department of Small Animal Clinical Sciences, University of Florida, Gainesville, FL 32610 (United States); Stuchal, L.D. [Center for Environmental and Human Toxicology, University of Florida, Gainesville, FL 32611 (United States); Department of Environmental and Global Health, College of Public Health and Health Professions, University of Florida, Gainesville, FL 32611 (United States); Ma, L.Q., E-mail: lqma@ufl.edu [State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Jiangsu 201146 (China); Soil and Water Science Department, University of Florida, Gainesville, FL 32611 (United States)

    2016-05-01

    Animal enclosures are often constructed from wood treated with the pesticide chromated copper arsenate (CCA), which leaches arsenic (As) into adjacent soil during normal weathering. This study evaluated potential pathways of As exposure in 25 species of zoo animals living in CCA-wood enclosures. We analyzed As speciation in complete animal foods, dislodgeable As from CCA-wood, and As levels in enclosure soils, as well as As levels in biomarkers of 9 species of crocodilians (eggs), 4 species of birds (feathers), 1 primate species (hair), and 1 porcupine species (quills). Elevated soil As in samples from 17 enclosures was observed at 1.0–110 mg/kg, and enclosures housing threatened and endangered species had As levels higher than USEPA's risk-based Eco-SSL for birds and mammals of 43 and 46 mg/kg. Wipe samples of CCA-wood on which primates sit had dislodgeable As residues of 4.6–111 μg/100 cm{sup 2}, typical of unsealed CCA-wood. Inorganic As doses from animal foods were estimated at 0.22–7.8 μg/kg bw/d. Some As levels in bird feathers and crocodilian eggs were higher than prior studies on wild species. However, hair from marmosets had 6.37 mg/kg As, 30-fold greater than the reference value, possibly due to their inability to methylate inorganic As. Our data suggested that elevated As in soils and dislodgeable As from CCA-wood could be important sources of As exposure for zoo animals. - Highlights: • Daily inorganic As dose from zoo animal foods was 0.22–7.8 μg/kg bw/day. • Total As concentrations in soils of zoo animal enclosures were 1.0–110 mg/kg. • Endangered zoo animals live in soils with As above USEPA Eco-SSLs for avian and mammal species. • Dislodgeable As on CCA-wood beams where primates sit was 4.6–111 μg/100 cm{sup 2}. • Marmoset hair had 6.37 mg/kg As compared to a reference value of 0.21 mg/kg.

  2. Primary functions of the first Japanese large-scale facility for exposing small animals to radon

    International Nuclear Information System (INIS)

    Ishimori, Yuu; Tanaka, Hiroshi; Mitsunobu, Fumihiro; Yamaoka, Kiyonori; Kataoka, Takahiro; Sakoda, Akihiro

    2010-01-01

    The Japan Atomic Energy Agency (JAEA) and Okayama University have carried out the experimental animal study and its related studies since 2007 in order to examine the physiological effects of radon in detail. Thus, a radon test facility for small animals was developed in order to increase the statistical certainty of our animal tests. This paper illustrates the performances of that facility, the first large-scale facility of its types in Japan. The facility has a potential of approximately 150 mouse-scale tests at the same time. The apparatus for exposing small animals to radon has six animal chamber groups each of which consists of five independent cages. Different radon concentrations in each animal chamber group are available. The major functions of the facility controlling radon and avoiding thoron were shown theoretically and experimentally. The relative standard deviation of radon concentration at the highest concentration group was about 5%, although the lower concentration groups seemed to be affected by variations in background radon. (author)

  3. Bone scintigraphy for the investigation of lameness in small animals

    International Nuclear Information System (INIS)

    Bolln, G.; Franke, C.

    2010-01-01

    Bone scintigraphy has been used as a helpful method in diagnosing lameness in small animals. It is a sensitive, non-invasive method to evaluate bone lesions and orthopaedic disorders. It provides a functional image of the skeleton and thereby aiding in the localisation and diagnosing of obscure lameness. Compared to human medicine one important difference is the inability of an animal to characterize its pain to the examiner. Another difference is the lacking cooperation of an animal during bone scintigraphy. Before this background are shown on the basis of 5 examples the advantages, the method and the different indication of bone scintigraphy. The technique of this method arrives from a human medicine protocol of a 2-phase-bone-scintigraphy and has to be done under light anaesthesia, to avoid artefacts of movement during acquisitions. The authors are convinced that bone scintigraphy is a very useful and diagnostic method for evaluation of obscure lameness because it can give a quick diagnosis and aimed therapy. Therefore secondary changes and additional costs can be avoided for the animal and its owner. (orig.)

  4. Teaching international animal agriculture.

    Science.gov (United States)

    Lukefahr, S D

    1999-11-01

    Students who major in animal science at U.S. institutions are generally exposed to a curriculum that emphasizes commercial, large-scale production of the few traditional food animals: cattle, poultry, sheep, and swine. Globally, most farmers live in lesser-developed countries under limited-resource conditions of land, feed supplies, equipment, and capital. The promotion of commercial animal production enterprises may not be appropriate for such farms because it can subject farmers to considerable economic risk. Rather, use of limited numbers of large livestock, locally adapted breeds, or smaller livestock (e.g., ducks, goats, guinea pigs, and rabbits) may be more appropriate under subsistence, integrated farming systems. In this global context, a course in international animal agriculture has been taught for 15 yr to undergraduate and graduate students. The course consists of a review of traditional and potential livestock species well suited for impoverished families on small farms and methods to implement sustainable livestock projects, including feasibility, design, implementation, monitoring, and evaluation stages. To enhance student understanding, global food issues and challenges are illustrated with case studies. A term paper is also assigned for which students choose three suitable livestock species or local breeds that would be complementary on a small crop farm (< 5 ha). Daily dietary requirements of protein and energy per family member are calculated. Itemized enterprise budgets and production tables are prepared. Early in the course, the general consensus of students was that people who are malnourished and live in poverty have low personal ambition and motivation, and that their problems should be amenable to solution by application of American technology and expertise. The course modifies such attitudes and enhances a student's critical thinking and problem-solving abilities and communication skills. Course evaluations indicated that students believed

  5. Harmful Effects of Nanoparticles on Animals

    Directory of Open Access Journals (Sweden)

    Jean-Marie Exbrayat

    2015-01-01

    Full Text Available Since several years nanoparticles (NPs are produced by industries and used in several fields of activities. They are finally found in aquatic and terrestrial environments, where they are ingested by living organisms in which they accumulate, before being eliminated. In organisms, NPs represent foreign elements with their own physicochemical properties due to their small size. So NPs may interfere with the normal physiological mechanisms of the embryos, growing animals, and adults, and it is indispensable to understand their potentially direct or indirect harmful effects on living organisms. It has been already shown that NPs could be toxic to bacteria, algae, invertebrates, and vertebrates. In this review, several examples of recent studies are given. We will examine successively the effects of NPs on terrestrial and semiaquatic and aquatic vertebrate and invertebrate animals.

  6. Evaluating performance of a pixel array semiconductor SPECT system for small animal imaging

    International Nuclear Information System (INIS)

    Kubo, Naoki; Zhao, Songji; Fujiki, Yutaka

    2005-01-01

    Small animal imaging has recently been focused on basic nuclear medicine. We have designed and built a small animal SPECT imaging system using a semiconductor camera and a newly designed collimator. We assess the performance of this system for small object imaging. We employed an MGC 1500 (Acrorad Co.) camera including a CdTe semiconductor. The pixel size was 1.4 mm/pixel. We designed and produced a parallel-hole collimator with 20-mm hole length. Our SPECT system consisted of a semiconductor camera with the subject holder set on an electric rotating stage controlled by a computer. We compared this system with a conventional small animal SPECT system comprising a SPECT-2000H scanner with four Anger type cameras and pinhole collimators. The count rate linearity for estimation of the scatter was evaluated for a pie-chart phantom containing different concentrations of 99m Tc. We measured the full width half maximum (FWHM) of the 99m Tc SPECT line source along with scatter. The system volume sensitivity was examined using a flood source phantom which was 35 mm long with a 32-mm inside diameter. Additionally, an in vivo myocardial perfusion SPECT study was performed with a rat. With regards to energy resolution, the semiconductor camera (5.6%) was superior to the conventional Anger type camera (9.8%). In the count rate linearity evaluation, the regression lines of the SPECT values were y=0.019x+0.031 (r 2 =0.999) for our system and y=0.018x+0.060 (r 2 =0.997) for the conventional system. Thus, the scatter count using the semiconductor camera was less than that using the conventional camera. FWHMs of our system and the conventional system were 2.9±0.1 and 2.0±0.1 mm, respectively. Moreover, the system volume sensitivity of our system [0.51 kcps/(MBq/ml)/cm] was superior to that of the conventional system [0.44 kcps/(MBq/ml)/cm]. Our system provided clear images of the rat myocardium, sufficient for practical use in small animal imaging. Our SPECT system, utilizing a

  7. Linking live animals and products: traceability.

    Science.gov (United States)

    Britt, A G; Bell, C M; Evers, K; Paskin, R

    2013-08-01

    It is rarely possible to successfully contain an outbreak of an infectious animal disease, or to respond effectively to a chemical residue incident, without the use of a system for identifying and tracking animals. The linking of animals at the time they are slaughtered--through the use of identification devices or marks and accompanying movement documentation--with the meat produced from their carcasses, adds further value from the perspective of consumer safety. Over the past decade, animal identification technology has become more sophisticated and affordable. The development of the Internet and mobile communication tools, complemented bythe expanded capacity of computers and associated data management applications, has added a new dimension to the ability of Competent Authorities and industry to track animals and the food they produce for disease control, food safety and commercial purposes.

  8. Open-source, small-animal magnetic resonance-guided focused ultrasound system.

    Science.gov (United States)

    Poorman, Megan E; Chaplin, Vandiver L; Wilkens, Ken; Dockery, Mary D; Giorgio, Todd D; Grissom, William A; Caskey, Charles F

    2016-01-01

    MR-guided focused ultrasound or high-intensity focused ultrasound (MRgFUS/MRgHIFU) is a non-invasive therapeutic modality with many potential applications in areas such as cancer therapy, drug delivery, and blood-brain barrier opening. However, the large financial costs involved in developing preclinical MRgFUS systems represent a barrier to research groups interested in developing new techniques and applications. We aim to mitigate these challenges by detailing a validated, open-source preclinical MRgFUS system capable of delivering thermal and mechanical FUS in a quantifiable and repeatable manner under real-time MRI guidance. A hardware and software package was developed that includes closed-loop feedback controlled thermometry code and CAD drawings for a therapy table designed for a preclinical MRI scanner. For thermal treatments, the modular software uses a proportional integral derivative controller to maintain a precise focal temperature rise in the target given input from MR phase images obtained concurrently. The software computes the required voltage output and transmits it to a FUS transducer that is embedded in the delivery table within the magnet bore. The delivery table holds the FUS transducer, a small animal and its monitoring equipment, and a transmit/receive RF coil. The transducer is coupled to the animal via a water bath and is translatable in two dimensions from outside the magnet. The transducer is driven by a waveform generator and amplifier controlled by real-time software in Matlab. MR acoustic radiation force imaging is also implemented to confirm the position of the focus for mechanical and thermal treatments. The system was validated in tissue-mimicking phantoms and in vivo during murine tumor hyperthermia treatments. Sonications were successfully controlled over a range of temperatures and thermal doses for up to 20 min with minimal temperature overshoot. MR thermometry was validated with an optical temperature probe, and focus

  9. Performance characteristics of a small animal PET camera for molecular imaging

    International Nuclear Information System (INIS)

    Hastings, D.L.; Reader, A.J.; Julyan, P.J.; Zweit, J.; Jeavons, A.P.; Jones, T.

    2007-01-01

    The performance of a novel type of animal PET camera, the quad High-Density Avalanche Chamber (HIDAC) was assessed for a non-rotating 16-module system. Spatial resolution was 1.0 mm, and invariant within a standard deviation ≤5%. Absolute sensitivity was 0.95%, and the scatter-background corrected sensitivity was 0.75%. The count rate capability was linear at typical activities used in animal imaging, with a 20% loss at 11.5 MBq. The camera demonstrates small regions of radiotracer uptake with excellent detail in the mouse

  10. The therapeutic lamp: treating small-animal phobias.

    Science.gov (United States)

    Wrzesien, Maja; Alcañiz, Mariano; Botella, Cristina; Burkhardt, Jean-Marie; Bretón-López, Juana; Ortega, Mario; Brotons, Daniel Beneito

    2013-01-01

    We all have an irrational fear or two. Some of us get scared by an unexpected visit from a spider in our house; others get nervous when they look down from a high building. Fear is an evolutionary and adaptive function that can promote self-preservation and help us deal with the feared object or situation. However, when this state becomes excessive, it might develop into psychological disorders such as phobias, producing high anxiety and affecting everyday life. The Therapeutic Lamp is an interactive projection-based augmented-reality system for treating small-animal phobias. It aims to increase patient-therapist communication, promote more natural interaction, and improve the patient's engagement in the therapy.

  11. [Live Animals and Staged Nature : Drawing and Photography in German Popular Zoology between 1860 and 1910].

    Science.gov (United States)

    Gall, Alexander

    2017-06-01

    It is the central thesis of this paper that the "biological perspective" (Lynn Nyhart) typical for Germany, with its interest in living animals, not only influenced natural history practices in many ways during the second half of the 19th century, rather also shaped the illustrations of popular zoology publications, as for example those in Brehms Thierleben. The illustrators of this period preferred to use live animals as models, which they studied in zoos. These animals were often depicted in their "natural" habitats. Since the illustrators knew only very little about these habitats, they had to be imagined. Another fashionable genre within popular zoology was the portrayal of animals fighting, which attracted attention because of their drama. The first wildlife photographers oriented themselves on the zoological illustrations and, with the aid of manipulation, staging and retouching, gave their photographs the impression of natural surroundings and drama. Yet both the illustrators and the photographers emphasized their truth to nature and - based on this - the scientific value of their pictures. In so doing, they developed a "biological" kind of wildlife photography, which, after the turn of the 19th century, allowed dedicated amateurs to create a popular zoological oeuvre that was well received by broad audiences.

  12. Cone Beam Micro-CT System for Small Animal Imaging and Performance Evaluation

    Directory of Open Access Journals (Sweden)

    Shouping Zhu

    2009-01-01

    in this paper. Experimental results show that the system is suitable for small animal imaging and is adequate to provide high-resolution anatomic information for bioluminescence tomography to build a dual modality system.

  13. Biodegradable polymer nanocarriers for therapeutic antisense microRNA delivery in living animals

    Science.gov (United States)

    Paulmurugan, Ramasamy; Sekar, Narayana M.; Sekar, Thillai V.

    2012-03-01

    MicroRNAs are endogenous regulators of gene expression, deregulated in several cellular diseases including cancer. Altering the cellular microenvironment by modulating the microRNAs functions can regulate different genes involved in major cellular processes, and this approach is now being investigated as a promising new generation of molecularly targeted anti-cancer therapies. AntagomiRs (Antisense-miRNAs) are a novel class of chemically modified stable oligonucleotides used for blocking the functions of endogenous microRNAs, which are overexpressed. A key challenge in achieving effective microRNAbased therapeutics lies in the development of an efficient delivery system capable of specifically delivering antisense oligonucleotides and target cancer cells in living animals. We are now developing an effective delivery system designed to selectively deliver antagomiR- 21 and antagomiR-10b to triple negative breast cancer cells, and to revert tumor cell metastasis and invasiveness. The FDA-approved biodegradable PLGA-nanoparticles were selected as a carrier for antagomiRs delivery. Chemically modified antagomiRs (antagomiR-21 and antagomiR-10b) were co-encapsulated in PEGylated-PLGA-nanoparticles by using the double-emulsification (W/O/W) solvent evaporation method, and the resulting average particle size of 150-200nm was used for different in vitro and in vivo experiments. The antagomiR encapsulated PLGA-nanoparticles were evaluated for their in vitro antagomiRs delivery, intracellular release profile, and antagomiRs functional effects, by measuring the endogenous cellular targets, and the cell growth and metastasis. The xenografts of tumor cells in living mice were used for evaluating the anti-metastatic and anti-invasive properties of cells. The results showed that the use of PLGA for antagomiR delivery is not only efficient in crossing cell membrane, but can also maintain functional intracellular antagomiRs level for a extended period of time and achieve

  14. Fully synthetic phage-like system for screening mixtures of small molecules in live cells.

    Science.gov (United States)

    Byk, Gerardo; Partouche, Shirly; Weiss, Aryeh; Margel, Shlomo; Khandadash, Raz

    2010-05-10

    A synthetic "phage-like" system was designed for screening mixtures of small molecules in live cells. The core of the system consists of 2 mum diameter cross-linked monodispersed microspheres bearing a panel of fluorescent tags and peptides or small molecules either directly synthesized or covalently conjugated to the microspheres. The microsphere mixtures were screened for affinity to cell line PC-3 (prostate cancer model) by incubation with live cells, and as was with phage-display peptide methods, unbound microspheres were removed by repeated washings followed by total lysis of cells and analysis of the bound microspheres by flow-cytometry. Similar to phage-display peptide screening, this method can be applied even in the absence of prior information about the cellular targets of the candidate ligands, which makes the system especially interesting for selection of molecules with high affinity for desired cells, tissues, or tumors. The advantage of the proposed system is the possibility of screening synthetic non-natural peptides or small molecules that cannot be expressed and screened using phage display libraries. A library composed of small molecules synthesized by the Ugi reaction was screened, and a small molecule, Rak-2, which strongly binds to PC-3 cells was found. Rak-2 was then individually synthesized and validated in a complementary whole cell-based binding assay, as well as by live cell microscopy. This new system demonstrates that a mixture of molecules bound to subcellular sized microspheres can be screened on plated cells. Together with other methods using subcellular sized particles for cellular multiplexing, this method represents an important milestone toward high throughput screening of mixtures of small molecules in live cells and in vivo with potential applications in the fields of drug delivery and diagnostic imaging.

  15. Threonine 53 in α-synuclein is conserved in long-living non-primate animals

    DEFF Research Database (Denmark)

    Larsen, Knud; Hedegaard, Claus; Bertelsen, Mads Frost

    2009-01-01

    α-Synuclein is the main constituent of Lewy bodies in familial and sporadic cases of Parkinson's disease (PD). Autosomal dominant point mutations, gene duplications or triplications in the α-synuclein (SNCA) gene cause hereditary forms of PD. One of the α-synuclein point mutations, Ala53Thr, is a...... that 53Thr is not a molecular adaptation for long-living animals to minimize the risk of developing PD...

  16. Fully automated intrinsic respiratory and cardiac gating for small animal CT

    Energy Technology Data Exchange (ETDEWEB)

    Kuntz, J; Baeuerle, T; Semmler, W; Bartling, S H [Department of Medical Physics in Radiology, German Cancer Research Center, Heidelberg (Germany); Dinkel, J [Department of Radiology, German Cancer Research Center, Heidelberg (Germany); Zwick, S [Department of Diagnostic Radiology, Medical Physics, Freiburg University (Germany); Grasruck, M [Siemens Healthcare, Forchheim (Germany); Kiessling, F [Chair of Experimental Molecular Imaging, RWTH-Aachen University, Medical Faculty, Aachen (Germany); Gupta, R [Department of Radiology, Massachusetts General Hospital, Boston, MA (United States)], E-mail: j.kuntz@dkfz.de

    2010-04-07

    A fully automated, intrinsic gating algorithm for small animal cone-beam CT is described and evaluated. A parameter representing the organ motion, derived from the raw projection images, is used for both cardiac and respiratory gating. The proposed algorithm makes it possible to reconstruct motion-corrected still images as well as to generate four-dimensional (4D) datasets representing the cardiac and pulmonary anatomy of free-breathing animals without the use of electrocardiogram (ECG) or respiratory sensors. Variation analysis of projections from several rotations is used to place a region of interest (ROI) on the diaphragm. The ROI is cranially extended to include the heart. The centre of mass (COM) variation within this ROI, the filtered frequency response and the local maxima are used to derive a binary motion-gating parameter for phase-sensitive gated reconstruction. This algorithm was implemented on a flat-panel-based cone-beam CT scanner and evaluated using a moving phantom and animal scans (seven rats and eight mice). Volumes were determined using a semiautomatic segmentation. In all cases robust gating signals could be obtained. The maximum volume error in phantom studies was less than 6%. By utilizing extrinsic gating via externally placed cardiac and respiratory sensors, the functional parameters (e.g. cardiac ejection fraction) and image quality were equivalent to this current gold standard. This algorithm obviates the necessity of both gating hardware and user interaction. The simplicity of the proposed algorithm enables adoption in a wide range of small animal cone-beam CT scanners.

  17. An automated robot arm system for small animal tissue biopsy under dual-image modality

    International Nuclear Information System (INIS)

    Huang, Y.H.; Wu, T.H.; Lin, M.H.; Yang, C.C.; Guo, W.Y.; Wang, Z.J.; Chen, C.L.; Lee, J.S.

    2006-01-01

    The ability to non-invasively monitor cell biology in vivo is one of the most important goals of molecular imaging. Imaging procedures could be inter-subject performed repeatedly at different investigating stages; thereby need not sacrifice small animals during the entire study period. Thus, the ultimate goal of this study was to design a stereotactic image-guided system for small animals and integrated it with an automatic robot arm for in vivo tissue biopsy analysis. The system was composed of three main parts, including one small animal stereotactic frame, one imaging-fusion software and an automatic robot arm system. The system has been thoroughly evaluated with three components; the robot position accuracy was 0.05±0.02 mm, the image registration accuracy was 0.37±0.18 mm and the system integration was satisfactorily within 1.20±0.39 mm of error. From these results, the system demonstrated sufficient accuracy to guide the micro-injector from the planned delivery routes into practice. The entire system accuracy was limited by the image fusion and orientation procedures, due to its nature of the blurred PET imaging obtained from the small objects. The primary improvement is to acquire as higher resolution as possible the fused imaging for localizing the targets in the future

  18. Performance of the first Japanese large-scale facility for radon inhalation experiments with small animals

    International Nuclear Information System (INIS)

    Ishimori, Y.; Mitsunobu, F.; Yamaoka, K.; Tanaka, H.; Kataoka, T.; Sakoda, A.

    2011-01-01

    A radon test facility for small animals was developed in order to increase the statistical validity of differences of the biological response in various radon environments. This paper illustrates the performances of that facility, the first large-scale facility of its kind in Japan. The facility has a capability to conduct approximately 150 mouse-scale tests at the same time. The apparatus for exposing small animals to radon has six animal chamber groups with five independent cages each. Different radon concentrations in each animal chamber group are available. Because the first target of this study is to examine the in vivo behaviour of radon and its effects, the major functions to control radon and to eliminate thoron were examined experimentally. Additionally, radon progeny concentrations and their particle size distributions in the cages were also examined experimentally to be considered in future projects. (authors)

  19. Veterinarians' perceptions of behaviour support in small-animal practice.

    Science.gov (United States)

    Roshier, A L; McBride, E A

    2013-03-09

    Veterinarians are professionals considered to be at the forefront of animal welfare, including behaviour medicine. However, concerns raised, both within the profession and without, highlight that the support offered is not optimal, due to deficiencies in veterinary training, which focuses on physical aspects and overlooks psychological aspects. This preliminary study explored the experiences and perceptions of six veterinarians (three male, three female, age range: 23-55 years) in two UK small-animal practices. Seventeen annual booster consultations were videoed and conversations thematically analysed for welfare topics discussed. Both veterinarians and clients completed questionnaires to gather demographic information and perspectives. All veterinarians recognised behaviour as a component of their caseload, and acknowledged that clients expected them to provide behaviour support. Veterinarians varied in their experiences of and confidence in providing behaviour support. Five felt unable to meet client expectations; four did not feel their training had prepared them sufficiently. Only one provided dedicated behaviour consultations, the others referred cases. All provided suggestions for behaviour skills needed for new veterinary graduates. The study has afforded an insight into the experiences of a small opportunistic sample of veterinarians. The data indicated important limitations regarding time available in general consultations to discuss behaviour concerns, and practitioner knowledge and skill in detection, anamnesis, assessment and provision of appropriate behaviour information. Suggestions for veterinary training in behaviour are provided.

  20. Management and Level of Asian small-clawed otter (Aonyx cinereus Illinger, 1815 as Display Animal in Indonesia Conservation Institution

    Directory of Open Access Journals (Sweden)

    Ulfa Hansyari Ar-Rasyid

    2017-09-01

    Full Text Available Education and breeding become main reasons for asian small-clawed otter placement as display animal in zoo. Proper management is needed to maintain asian small-clawed otter welfare. This research objectives were to examine and assess asian small-clawed otter welfare in three Indonesia zoos. The study was conducted from December 2016 to February 2017 in Bandung Zoo, Ragunan Zoo and Ocean Dream Samudra Ancol. The methods of this research were literature review, interview and field observation. Data were analyzed using the suitability of management and animal welfare assessment. The result showed that there were three main management activities conducted at the three study locations, i.e., nutrition, housing, and health management. Bandung Zoo achieved the lowest score of asian small-clawed otter welfare (45,24% compared to Ragunan Zoo (62,24% and Ocean Dream Samudra (65,90%. Asian small-clawed otter welfare in three institutions were relatively low to fair category, this was due to the unfilled quality of food and water i.e.,  the type, amount, feeding frequency, diet and preparing of food; the unavailability of suitable and favorable environmental conditions; the care facilities provided could not ensure the health of animal; the appearance of abnormal behavior that affected the growth and breeding of animal; and animal had no freedom to behave as in their natural habitat. Keywords: animal display, animal welfare, Asian small-clawed otter, zoo 

  1. A new small-animal model for the study of acquired heterotopic ossification after hip surgery.

    Science.gov (United States)

    Anthonissen, Joris; Ossendorf, Christian; Hock, Johanna Lisa; Ritz, Ulrike; Hofmann, Alexander; Rommens, Pol Maria

    2015-01-01

    Heterotopic ossification (HO)--the formation of bone in soft tissues--is a frequent problem after surgery of the hip and pelvis, but little is known about its underlying pathogenic mechanisms. It is vital to study the underlying pathogenesis in animal models to develop and evaluate new prophylactic regimens directed against HO. However, previously developed small-animal models for the study of HO imitate neither surgery nor trauma-mechanisms that potentially cause HO. Hence, the goal of this study was to develop a novel small-animal model imitating hip surgery that can reliably produce HO. Twenty male Wistar rats were subjected to surgery of the right hip during which the femoral canal was reamed in three steps up to 2 mm, and a muscle lesion was made. Twelve weeks after surgery, the amount of heterotopic bone was assessed using micro-computed tomography. Eighteen of 20 animals showed HO around the hip 12 weeks after surgery. The amount of heterotopic bone varied from very small particles up to near ankylosis. A rat model of hip/pelvic surgery that does not use exogenous osteogenic stimulus and can reliably produce HO was developed.

  2. The zoonotic potential of Clostridium difficile from small companion animals and their owners.

    Science.gov (United States)

    Rabold, Denise; Espelage, Werner; Abu Sin, Muna; Eckmanns, Tim; Schneeberg, Alexander; Neubauer, Heinrich; Möbius, Nadine; Hille, Katja; Wieler, Lothar H; Seyboldt, Christian; Lübke-Becker, Antina

    2018-01-01

    Clostridium difficile infections (CDI) in humans range from asymptomatic carriage to life-threatening intestinal disease. Findings on C. difficile in various animal species and an overlap in ribotypes (RTs) suggest potential zoonotic transmission. However, the impact of animals for human CDI remains unclear. In a large-scale survey we collected 1,447 fecal samples to determine the occurrence of C. difficile in small companion animals (dogs and cats) and their owners and to assess potential epidemiological links within the community. The Germany-wide survey was conducted from July 2012-August 2013. PCR ribotyping, Multilocus VNTR Analysis (MLVA) and PCR detection of toxin genes were used to characterize isolated C. difficile strains. A database was defined and logistic regression used to identify putative factors associated with fecal shedding of C. difficile. In total, 1,418 samples met the inclusion criteria. The isolation rates for small companion animals and their owners within the community were similarly low with 3.0% (25/840) and 2.9% (17/578), respectively. PCR ribotyping revealed eight and twelve different RTs in animals and humans, respectively, whereas three RTs were isolated in both, humans and animals. RT 014/0, a well-known human hospital-associated lineage, was predominantly detected in animal samples. Moreover, the potentially highly pathogenic RTs 027 and 078 were isolated from dogs. Even though, C. difficile did not occur simultaneously in animals and humans sharing the same household. The results of the epidemiological analysis of factors associated with fecal shedding of C. difficile support the hypothesis of a zoonotic potential. Molecular characterization and epidemiological analysis revealed that the zoonotic risk for C. difficile associated with dogs and cats within the community is low but cannot be excluded.

  3. Monitoring of Yersinia enterocolitica strains from free-living animals using different methods.

    Science.gov (United States)

    Syczyło, K; Platt-Samoraj, A; Bancerz-Kisiel, A; Szczerba-Turek, A; Lipczyńska, K; Jabłoński, A; Procajło, Z; Szweda, W

    2016-01-01

    The aim of the study was to monitor Y. enterocolitica strains from free-living animals captured during 2011-2014 hunting seasons in Poland using warm (ITC) and cold (PSB) enrichment and molecular examination. Over 1600 samples have been cultured. After ITC/PSB enrichment 237 strains presenting features characteristic for Y. enterocolitica were isolated. Molecular examination using multiplex PCR revealed 140 isolates from PSB and 78 from ITC. The concentration of pathogenic Yersinia in asymptomatic carriers is low and the PCR detection should be preceded by bacteriological examination.

  4. Don't Sweat the Small Stuff: Food Allergy Sufferer Lives a Cautious but Normal Life

    Science.gov (United States)

    ... Current Issue Past Issues Home Current issue contents Food allergy sufferer lives a cautious but normal life Follow us Don’t Sweat the Small Stuff Food allergy sufferer lives a cautious but normal life Anthony ...

  5. Imaging of lung metastasis tumor mouse model using [{sup 18}F]FDG small animal PET and CT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, June Youp; Woo, Sang Keun; Lee, Tae Sup [Korea Institute of Radiological and Medical Sciences (KIRAMS), Seoul (Korea, Republic of)] (and others)

    2007-02-15

    The purpose of this study is to image metastaic lung melanoma model with optimal pre-conditions for animal handling by using [{sup 18}F]FDG small animal PET and clinical CT. The pre-conditions for lung region tumor imaging were 16-22 h fasting and warming temperature at 30 .deg. C. Small animal PET image was obtained at 60 min postinjection of 7.4 MBq [{sup 18}F]FDG and compared pattern of [{sup 18}F]FDG uptake and glucose standard uptake value (SUVG) of lung region between Ketamine/Xylazine (Ke/Xy) and Isoflurane (Iso) anesthetized group in normal mice. Metastasis tumor mouse model to lung was established by intravenous injection of B16-F10 cells in C57BL/6 mice. In lung metastasis tumor model, [{sup 18}F]FDG image was obtained and fused with anatomical clinical CT image. Average blood glucose concentration in normal mice were 128.0 {+-} 22.87 and 86.0 {+-} 21.65 mg/dL in Ke/Xy group and Iso group, respectively. Ke/Xy group showed 1.5 fold higher blood glucose concentration than Iso group. Lung to Background ratio (L/B) in SUVG image was 8.6 {+-} 0.48 and 12.1 {+-}0.63 in Ke/Xy group and Iso group, respectively. In tumor detection in lung region, [{sup 18}F]FDG image of Iso group was better than that of Ke/Xy group, because of high L/B ratio. Metastatic tumor location in [{sup 18}F]FDG small animal PET image was confirmed by fusion image using clinical CT. Tumor imaging in small animal lung region with [{sup 18}F]FDG small animal PET should be considered pre-conditions which fasting, warming and an anesthesia during [{sup 18}F]FDG uptake. Fused imaging with small animal PET and CT image could be useful for the detection of metastatic tumor in lung region.

  6. Current status and future perspectives of in vivo small animal imaging using radiolabeled nanoparticles

    International Nuclear Information System (INIS)

    Loudos, George; Kagadis, George C.; Psimadas, Dimitris

    2011-01-01

    Small animal molecular imaging is a rapidly expanding efficient tool to study biological processes non-invasively. The use of radiolabeled tracers provides non-destructive, imaging information, allowing time related phenomena to be repeatedly studied in a single animal. In the last decade there has been an enormous progress in related technologies and a number of dedicated imaging systems overcome the limitations that the size of small animal possesses. On the other hand, nanoparticles (NPs) gain increased interest, due to their unique properties, which make them perfect candidates for biological applications. Over the past 5 years the two fields seem to cross more and more often; radiolabeled NPs have been assessed in numerous pre-clinical studies that range from oncology, till HIV treatment. In this article the current status in the tools, applications and trends of radiolabeled NPs reviewed.

  7. Nigerian Veterinary Journal The record of J 14small animal trauma ...

    African Journals Online (AJOL)

    base for the establishment of protocols for trauma patient care. Trauma cases ranked first and accounted fOT46.3% of all small animal surgical cases presented during the period. Species involvement markedly favoured the canine species. Incidence of trauma was significantly higher (1)<0.05) in males (60.5%) and younger.

  8. Attitudes of Austrian veterinarians towards euthanasia in small animal practice: impacts of age and gender on views on euthanasia

    OpenAIRE

    Hartnack, Sonja; Springer, Svenja; Pittavino, Marta; Grimm, Herwig

    2016-01-01

    Background Euthanasia of pets has been described by veterinarians as ?the best and the worst? of the profession. The most commonly mentioned ethical dilemmas veterinarians face in small animal practice are: limited treatment options due to financial constraints, euthanizing of healthy animals and owners wishing to continue treatment of terminally ill animals. The aim of the study was to gain insight into the attitudes of Austrian veterinarians towards euthanasia of small animals. This include...

  9. Evaluation of a cone beam computed tomography geometry for image guided small animal irradiation

    International Nuclear Information System (INIS)

    Yang, Yidong; Armour, Michael; Wang, Ken Kang-Hsin; Gandhi, Nishant; Wong, John; Iordachita, Iulian; Siewerdsen, Jeffrey

    2015-01-01

    The conventional imaging geometry for small animal cone beam computed tomography (CBCT) is that a detector panel rotates around the head-to-tail axis of an imaged animal (‘tubular’ geometry). Another unusual but possible imaging geometry is that the detector panel rotates around the anterior-to-posterior axis of the animal (‘pancake’ geometry). The small animal radiation research platform developed at Johns Hopkins University employs the pancake geometry where a prone-positioned animal is rotated horizontally between an x-ray source and detector panel. This study is to assess the CBCT image quality in the pancake geometry and investigate potential methods for improvement. We compared CBCT images acquired in the pancake geometry with those acquired in the tubular geometry when the phantom/animal was placed upright simulating the conventional CBCT geometry. Results showed signal-to-noise and contrast-to-noise ratios in the pancake geometry were reduced in comparison to the tubular geometry at the same dose level. But the overall spatial resolution within the transverse plane of the imaged cylinder/animal was better in the pancake geometry. A modest exposure increase to two folds in the pancake geometry can improve image quality to a level close to the tubular geometry. Image quality can also be improved by inclining the animal, which reduces streak artifacts caused by bony structures. The major factor resulting in the inferior image quality in the pancake geometry is the elevated beam attenuation along the long axis of the phantom/animal and consequently increased scatter-to-primary ratio in that orientation. Not withstanding, the image quality in the pancake-geometry CBCT is adequate to support image guided animal positioning, while providing unique advantages of non-coplanar and multiple mice irradiation. This study also provides useful knowledge about the image quality in the two very different imaging geometries, i.e. pancake and tubular geometry

  10. Evaluation of a cone beam computed tomography geometry for image guided small animal irradiation.

    Science.gov (United States)

    Yang, Yidong; Armour, Michael; Wang, Ken Kang-Hsin; Gandhi, Nishant; Iordachita, Iulian; Siewerdsen, Jeffrey; Wong, John

    2015-07-07

    The conventional imaging geometry for small animal cone beam computed tomography (CBCT) is that a detector panel rotates around the head-to-tail axis of an imaged animal ('tubular' geometry). Another unusual but possible imaging geometry is that the detector panel rotates around the anterior-to-posterior axis of the animal ('pancake' geometry). The small animal radiation research platform developed at Johns Hopkins University employs the pancake geometry where a prone-positioned animal is rotated horizontally between an x-ray source and detector panel. This study is to assess the CBCT image quality in the pancake geometry and investigate potential methods for improvement. We compared CBCT images acquired in the pancake geometry with those acquired in the tubular geometry when the phantom/animal was placed upright simulating the conventional CBCT geometry. Results showed signal-to-noise and contrast-to-noise ratios in the pancake geometry were reduced in comparison to the tubular geometry at the same dose level. But the overall spatial resolution within the transverse plane of the imaged cylinder/animal was better in the pancake geometry. A modest exposure increase to two folds in the pancake geometry can improve image quality to a level close to the tubular geometry. Image quality can also be improved by inclining the animal, which reduces streak artifacts caused by bony structures. The major factor resulting in the inferior image quality in the pancake geometry is the elevated beam attenuation along the long axis of the phantom/animal and consequently increased scatter-to-primary ratio in that orientation. Not withstanding, the image quality in the pancake-geometry CBCT is adequate to support image guided animal positioning, while providing unique advantages of non-coplanar and multiple mice irradiation. This study also provides useful knowledge about the image quality in the two very different imaging geometries, i.e. pancake and tubular geometry, respectively.

  11. Small and large animal models in cardiac contraction research: advantages and disadvantages.

    Science.gov (United States)

    Milani-Nejad, Nima; Janssen, Paul M L

    2014-03-01

    The mammalian heart is responsible for not only pumping blood throughout the body but also adjusting this pumping activity quickly depending upon sudden changes in the metabolic demands of the body. For the most part, the human heart is capable of performing its duties without complications; however, throughout many decades of use, at some point this system encounters problems. Research into the heart's activities during healthy states and during adverse impacts that occur in disease states is necessary in order to strategize novel treatment options to ultimately prolong and improve patients' lives. Animal models are an important aspect of cardiac research where a variety of cardiac processes and therapeutic targets can be studied. However, there are differences between the heart of a human being and an animal and depending on the specific animal, these differences can become more pronounced and in certain cases limiting. There is no ideal animal model available for cardiac research, the use of each animal model is accompanied with its own set of advantages and disadvantages. In this review, we will discuss these advantages and disadvantages of commonly used laboratory animals including mouse, rat, rabbit, canine, swine, and sheep. Since the goal of cardiac research is to enhance our understanding of human health and disease and help improve clinical outcomes, we will also discuss the role of human cardiac tissue in cardiac research. This review will focus on the cardiac ventricular contractile and relaxation kinetics of humans and animal models in order to illustrate these differences. © 2013.

  12. Validity of bioluminescence measurements for noninvasive in vivo imaging of tumor load in small animals

    NARCIS (Netherlands)

    Klerk, Clara P. W.; Overmeer, Renée M.; Niers, Tatjana M. H.; Versteeg, Henri H.; Richel, Dick J.; Buckle, Tessa; van Noorden, Cornelis J. F.; van Tellingen, Olaf

    2007-01-01

    A relatively new strategy to longitudinally monitor tumor load in intact animals and the effects of therapy is noninvasive bioluminescence imaging (BLI). The validity of BLI for quantitative assessment of tumor load in small animals is critically evaluated in the present review. Cancer cells are

  13. The motivations and methodology for high-throughput PET imaging of small animals in cancer research.

    NARCIS (Netherlands)

    Aide, N.; Visser, E.P.; Lheureux, S.; Heutte, N.; Szanda, I.; Hicks, R.J.

    2012-01-01

    Over the last decade, small-animal PET imaging has become a vital platform technology in cancer research. With the development of molecularly targeted therapies and drug combinations requiring evaluation of different schedules, the number of animals to be imaged within a PET experiment has

  14. Low relative error in consumer-grade GPS units make them ideal for measuring small-scale animal movement patterns

    Directory of Open Access Journals (Sweden)

    Greg A. Breed

    2015-08-01

    Full Text Available Consumer-grade GPS units are a staple of modern field ecology, but the relatively large error radii reported by manufacturers (up to 10 m ostensibly precludes their utility in measuring fine-scale movement of small animals such as insects. Here we demonstrate that for data collected at fine spatio-temporal scales, these devices can produce exceptionally accurate data on step-length and movement patterns of small animals. With an understanding of the properties of GPS error and how it arises, it is possible, using a simple field protocol, to use consumer grade GPS units to collect step-length data for the movement of small animals that introduces a median error as small as 11 cm. These small error rates were measured in controlled observations of real butterfly movement. Similar conclusions were reached using a ground-truth test track prepared with a field tape and compass and subsequently measured 20 times using the same methodology as the butterfly tracking. Median error in the ground-truth track was slightly higher than the field data, mostly between 20 and 30 cm, but even for the smallest ground-truth step (70 cm, this is still a signal-to-noise ratio of 3:1, and for steps of 3 m or more, the ratio is greater than 10:1. Such small errors relative to the movements being measured make these inexpensive units useful for measuring insect and other small animal movements on small to intermediate scales with budgets orders of magnitude lower than survey-grade units used in past studies. As an additional advantage, these units are simpler to operate, and insect or other small animal trackways can be collected more quickly than either survey-grade units or more traditional ruler/gird approaches.

  15. Ethical dilemmas encountered by small animal veterinarians: characterisation, responses, consequences and beliefs regarding euthanasia.

    Science.gov (United States)

    Kipperman, Barry; Morris, Patricia; Rollin, Bernard

    2018-05-12

    Small animal veterinarians' opinions were investigated regarding the frequency and nature of ethical dilemmas encountered, beliefs regarding euthanasia and balancing client and animal interests, prevalence and value of ethics training and proposals to mitigate the stressful effects of ethical dilemmas. The majority (52 per cent) of 484 respondents in the USA indicated via an online survey experiencing an ethical dilemma regarding the interests of clients and those of their patients at least weekly. Scenarios involving client financial concerns were commonly reported causes of ethical conflicts. While only 20 per cent of respondents indicated that other practitioners prioritise patient interests, 50 per cent of respondents characterised their own behaviour as prioritising patients. Most respondents (52 per cent) reported that ethical dilemmas are the leading cause, or are one of many equal causes, of work-related stress. Less experienced practitioners, general practitioners and associate veterinarians were more likely to encounter situations they defined as ethical dilemmas, and female respondents were more likely to find ethical dilemmas stressful. Most small animal veterinarians experience ethical dilemmas regularly, which contribute to moral stress. Results suggested that most small animal practitioners believe that greater awareness of moral stress and providing training in ethical theories and tools for coping with ethical dilemmas can ameliorate moral stress. © British Veterinary Association (unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  16. SU-E-T-457: Design and Characterization of An Economical 192Ir Hemi-Brain Small Animal Irradiator

    International Nuclear Information System (INIS)

    Grams, M; Wilson, Z; Sio, T; Beltran, C; Tryggestad, E; Gupta, S; Blackwell, C; McCollough, K; Sarkaria, J; Furutani, K

    2014-01-01

    Purpose: To describe the design and dosimetric characterization of a simple and economical small animal irradiator. Methods: A high dose rate 192Ir brachytherapy source from a commercially available afterloader was used with a 1.3 centimeter thick tungsten collimator to provide sharp beam penumbra suitable for hemi-brain irradiation of mice. The unit is equipped with continuous gas anesthesia to allow robust animal immobilization. Dosimetric characterization of the device was performed with Gafchromic film. The penumbra from the small animal irradiator was compared under similar collimating conditions to the penumbra from 6 MV photons, 6 MeV electrons, and 20 MeV electrons from a linear accelerator as well as 300 kVp photons from an orthovoltage unit and Monte Carlo simulated 90 MeV protons. Results: The tungsten collimator provides a sharp penumbra suitable for hemi-brain irradiation, and dose rates on the order of 200 cGy/minute were achieved. The sharpness of the penumbra attainable with this device compares favorably to those measured experimentally for 6 MV photons, and 6 and 20 MeV electron beams from a linear accelerator. Additionally, the penumbra was comparable to those measured for a 300 kVp orthovoltage beam and a Monte Carlo simulated 90 MeV proton beam. Conclusions: The small animal irradiator described here can be built for under $1,000 and used in conjunction with any commercial brachytherapy afterloader to provide a convenient and cost-effective option for small animal irradiation experiments. The unit offers high dose rate delivery and sharp penumbra, which is ideal for hemi-brain irradiation of mice. With slight modifications to the design, irradiation of sites other than the brain could be accomplished easily. Due to its simplicity and low cost, the apparatus described is an attractive alternative for small animal irradiation experiments requiring a sharp penumbra

  17. An application of a new planar positron imaging system (PPIS) in a small animal. MPTP-induced parkinsonism in mouse

    International Nuclear Information System (INIS)

    Takamatsu, Hiroyuki; Noda, Akihiro; Kakiuchi, Takeharu

    2004-01-01

    Recent animal PET research has led to the development of PET scanners for small animals. A planar positron imaging system (PPIS) was newly developed to study physiological function in small animals and plants in recent years. To examine the usefulness of PPIS for functional study in small animals, we examined dopaminergic images of mouse striata in MPTP-induced parkinsonism. Male C57BL/6NCrj mice were treated with MPTP 7 days before the PPIS study. Scans were performed to measure dopamine D 1 receptor binding and dopamine transporter availability with [ 11 C]SCH23390 (about 2 MBq) and [ 11 C]β-CFT (about 2 MBq), respectively. After the PPIS study, dopamine content in the striatum was measured by high-performance liquid chromatography (HPLC). The MPTP treatment significantly reduced dopamine content in the striatum 7 days after treatment. In the MPTP-treated group, [ 11 C]β-CFT binding in the striatum was significantly decreased compared with the control group, while striatal [ 11 C]SCH23390 binding was not affected. Dopamine content in the striatum was significantly correlated with the striatal binding of [ 11 C]β-CFT. The present results suggest that PPIS is able to determine brain function in a small animal. Using PPIS, high throughput imaging of small animal brain functions could be achieved. (author)

  18. Use of luciferase probes to measure ATP in living cells and animals.

    Science.gov (United States)

    Morciano, Giampaolo; Sarti, Alba Clara; Marchi, Saverio; Missiroli, Sonia; Falzoni, Simonetta; Raffaghello, Lizzia; Pistoia, Vito; Giorgi, Carlotta; Di Virgilio, Francesco; Pinton, Paolo

    2017-08-01

    ATP, the energy exchange factor that connects anabolism and catabolism, is required for major reactions and processes that occur in living cells, such as muscle contraction, phosphorylation and active transport. ATP is also the key molecule in extracellular purinergic signaling mechanisms, with an established crucial role in inflammation and several additional disease conditions. Here, we describe detailed protocols to measure the ATP concentration in isolated living cells and animals using luminescence techniques based on targeted luciferase probes. In the presence of magnesium, oxygen and ATP, the protein luciferase catalyzes oxidation of the substrate luciferin, which is associated with light emission. Recombinantly expressed wild-type luciferase is exclusively cytosolic; however, adding specific targeting sequences can modify its cellular localization. Using this strategy, we have constructed luciferase chimeras targeted to the mitochondrial matrix and the outer surface of the plasma membrane. Here, we describe optimized protocols for monitoring ATP concentrations in the cytosol, mitochondrial matrix and pericellular space in living cells via an overall procedure that requires an average of 3 d. In addition, we present a detailed protocol for the in vivo detection of extracellular ATP in mice using luciferase-transfected reporter cells. This latter procedure may require up to 25 d to complete.

  19. Long-lived radicals produced by γ-irradiation or vital activity in plants, animals, cells, and protein solution: their observation and inhomogeneous decay dynamics

    International Nuclear Information System (INIS)

    Miyazaki, Tetsuo; Morikawa, Akiyuki; Kumagai, Jun; Ikehata, Masateru; Koana, Takao; Kikuchi, Shoshi

    2002-01-01

    Long-lived radicals produced by γ-irradiation or vital activity in plants, animals, cells, and protein (albumin) solution were studied by electron spin resonance spectroscopy. Long-lived radicals produced by vital activity exist in biological systems, such as plants, animals, and cells, in the range of 0.1-20 nmol g -1 . Since vital organs keep the radicals at a constant concentration, the radicals are probably related to life conservation. Long-lived radicals are also produced by γ-irradiation of cells or protein solution. The radicals decay after death of living things or after γ-irradiation. We found that the decay dynamics in all biological systems can be expressed by the same kinetic equation of an inhomogeneous reaction

  20. Collimator optimization for small animal radiation therapy at a micro-CT

    Energy Technology Data Exchange (ETDEWEB)

    Felix, Manuela C. [Heidelberg Univ., Mannheim (Germany). Medical Radiation Physics/Radiation Protection; Heidelberg Univ., Mannheim (Germany). Dept. of Radiation Oncology; Glatting, Gerhard [Heidelberg Univ., Mannheim (Germany). Medical Radiation Physics/Radiation Protection; Giordano, Frank A.; Wenz, Frederik; Fleckenstein, Jens [Heidelberg Univ., Mannheim (Germany). Dept. of Radiation Oncology; Brockmann, Marc A. [Heidelberg Univ., Mannheim (Germany). Dept. of Neuroradiology; University Medical Center Mainz (Germany). Dept. of Neuroradiology

    2017-05-01

    In radiation therapy of small animals treatment depths range from a few millimetres to several centimetres. In order to spare surrounding organs at risk steep dose gradients are necessary. To minimize the treatment time, and therefore the strain to the animals, a high dose rate is required. A description how these parameters can be optimized through an appropriate choice of collimators with different source surface distances (SSD) as well as different materials and geometries is presented. An industrial micro-CT unit (Y.Fox, YXLON GmbH, Hamburg, Germany) was converted into a precision irradiator for small animals. Different collimators of either stainless steel (Fe) with cylindrical bores (SSD = 42 mm) or tungsten (W) with conical bores (SSD = 14 mm) were evaluated. The dosimetry of very small radiation fields presents a challenge and was performed with GafChromic EBT3 films (Ashland, Vayne, KY, USA) in a water phantom. The films were calibrated with an ionization chamber in the uncollimated field. Treatments were performed via a rotation of the objects with a fixed radiation source. As expected, the shorter SSD of the W-collimators resulted in a (4.5 ± 1.6)-fold increase of the dose rates compared to the corresponding Fe-collimators. The ratios of the dose rates at 1 mm and 10 mm depth in the water phantom was (2.6 ± 0.2) for the Fe- and (4.5 ± 0.1) for the W-collimators. For rotational treatments in a cylindrical plastic phantom maximum dose rates of up to 1.2 Gy/min for Fe- and 5.1 Gy/min for W-collimators were measured. Choosing the smallest possible SSD leads to a high dose rate and a high surface dose, which is of advantage for the treatment of superficial target volumes. For larger SSD the dose rate is lower and the depth dose curve is shallower. This leads to a reduction of the surface dose and is best suited for treatments of deeper seated target volumes. Divergent collimator bores have, due to the reduced scatter within the collimators, a steeper

  1. Anesthesia condition for 18F-FDG imaging of lung metastasis tumors using small animal PET

    International Nuclear Information System (INIS)

    Woo, Sang-Keun; Lee, Tae Sup; Kim, Kyeong Min; Kim, June-Youp; Jung, Jae Ho; Kang, Joo Hyun; Cheon, Gi Jeong; Choi, Chang Woon; Lim, Sang Moo

    2008-01-01

    Small animal positron emission tomography (PET) with 18 F-FDG has been increasingly used for tumor imaging in the murine model. The aim of this study was to establish the anesthesia condition for imaging of lung metastasis tumor using small animal 18 F-FDG PET. Methods: To determine the impact of anesthesia on 18 F-FDG distribution in normal mice, five groups were studied under the following conditions: no anesthesia, ketamine and xylazine (Ke/Xy), 0.5% isoflurane (Iso 0.5), 1% isoflurane (Iso 1) and 2% isoflurane (Iso 2). The ex vivo counting, standard uptake value (SUV) image and glucose SUV of 18 F-FDG in various tissues were evaluated. The 18 F-FDG images in the lung metastasis tumor model were obtained under no anesthesia, Ke/Xy and Iso 0.5, and registered with CT image to clarify the tumor region. Results: Blood glucose concentration and muscle uptake of 18 F-FDG in the Ke/Xy group markedly increased more than in the other groups. The Iso 2 group increased 18 F-FDG uptake in heart compared with the other groups. The Iso 0.5 anesthesized group showed the lowest 18 F-FDG uptake in heart and chest wall. The small size of lung metastasis tumor (2 mm) was clearly visualized by 18 F-FDG image with the Iso 0.5 anesthesia. Conclusion: Small animal 18 F-FDG PET imaging with Iso 0.5 anesthesia was appropriate for the detection of lung metastasis tumor. To acquire 18 F-FDG PET images with small animal PET, the type and level of anesthetic should be carefully considered to be suitable for the visualization of target tissue in the experimental model

  2. Laboratory animal: biological reagent or living being?

    Science.gov (United States)

    Cardoso, C V P; Almeida, A E C C de

    2014-01-01

    The duties of humans toward non-human animals and their rights in society have been debated for a long time. However, a discussion on the terminology used for the identification of laboratory animals is usually not considered, although the employment of inadequate terminology may generate disastrous consequences for the animals before, during, and after the experiment. This study intends to defend the use of appropriate terminology, call attention to an unethical attitude of certain professionals when dealing with experimental animals, and also propose operational mechanisms, which allow for those distortions to be corrected.

  3. Biological X-ray irradiator characterization for use with small animals and cells.

    Science.gov (United States)

    Bruno, A Colello; Mazaro, S J; Amaral, L L; Rego, E M; Oliveira, H F; Pavoni, J F

    2017-03-02

    This study presents the characterization of an X-ray irradiator through dosimetric tests, which confirms the actual dose rate that small animals and cells will be exposed to during radiobiological experiments. We evaluated the linearity, consistency, repeatability, and dose distribution in the positions in which the animals or cells are placed during irradiation. In addition, we evaluated the performance of the X-ray tube (voltage and tube operating current), the radiometric survey (leakage radiation) and safety devices. The irradiator default setting was established as 160 kV and 25 mA. Tests showed that the dose rate was linear overtime (R2=1) and remained stable for long (constant) and short (repeatability) intervals between readings. The mean dose rate inside the animal cages was 1.27±0.06 Gy/min with a uniform beam of 95.40% (above the minimum threshold guaranteed by the manufacturer). The mean dose rate inside the cell plates was 0.92±0.19 Gy/min. The dose rate dependence with tube voltage and current presented a quadratic and linear relationship, respectively. There was no observed mechanical failure during evaluation of the irradiator safety devices and the radiometric survey obtained a maximum ambient equivalent dose rate of 0.26 mSv/h, which exempts it from the radiological protection requirements of the International Atomic Energy Agency. The irradiator characterization enables us to perform radiobiological experiments, and assists or even replaces traditional therapy equipment (e.g., linear accelerators) for cells and small animal irradiation, especially in early research stages.

  4. Biological X-ray irradiator characterization for use with small animals and cells

    Directory of Open Access Journals (Sweden)

    A. Colello Bruno

    Full Text Available This study presents the characterization of an X-ray irradiator through dosimetric tests, which confirms the actual dose rate that small animals and cells will be exposed to during radiobiological experiments. We evaluated the linearity, consistency, repeatability, and dose distribution in the positions in which the animals or cells are placed during irradiation. In addition, we evaluated the performance of the X-ray tube (voltage and tube operating current, the radiometric survey (leakage radiation and safety devices. The irradiator default setting was established as 160 kV and 25 mA. Tests showed that the dose rate was linear overtime (R2=1 and remained stable for long (constant and short (repeatability intervals between readings. The mean dose rate inside the animal cages was 1.27±0.06 Gy/min with a uniform beam of 95.40% (above the minimum threshold guaranteed by the manufacturer. The mean dose rate inside the cell plates was 0.92±0.19 Gy/min. The dose rate dependence with tube voltage and current presented a quadratic and linear relationship, respectively. There was no observed mechanical failure during evaluation of the irradiator safety devices and the radiometric survey obtained a maximum ambient equivalent dose rate of 0.26 mSv/h, which exempts it from the radiological protection requirements of the International Atomic Energy Agency. The irradiator characterization enables us to perform radiobiological experiments, and assists or even replaces traditional therapy equipment (e.g., linear accelerators for cells and small animal irradiation, especially in early research stages.

  5. Dynamic studies of small animals with a four-color diffuse optical tomography imager

    International Nuclear Information System (INIS)

    Schmitz, Christoph H.; Graber, Harry L.; Pei Yaling; Farber, Mark; Stewart, Mark; Levina, Rita D.; Levin, Mikhail B.; Xu Yong; Barbour, Randall L.

    2005-01-01

    We present newly developed instrumentation for full-tomographic four-wavelength, continuous wave, diffuse optical tomography (DOT) imaging on small animals. A small-animal imaging stage was constructed, from materials compatible with in-magnet studies, which offers stereotaxic fixation of the animal and precise, stable probe positioning. Instrument performance, based on calibration and phantom studies, demonstrates excellent long-term signal stability. DOT measurements of the functional rat brain response to electric paw stimulation are presented, and these demonstrate high data quality and excellent sensitivity to hemodynamic changes. A general linear model analysis on individual trials is used to localize and quantify the occurrence of functional behavior associated with the different hemoglobin state responses. Statistical evaluation of outcomes of individual trials is employed to identify significant regional response variations for different stimulation sites. Image results reveal a diffuse cortical response and a strong reaction of the thalamus, both indicative of activation of pain pathways by the stimulation. In addition, a weaker lateralized functional component is observed in the brain response, suggesting presence of motor activation. An important outcome of the experiment is that it shows that reactions to individual provocations can be monitored, without having to resort to signal averaging. Thus the described technology may be useful for studies of long-term trends in hemodynamic response, as would occur, for example, in behavioral studies involving freely moving animals

  6. A 3D HIDAC-PET camera with sub-millimeter resolution for imaging small animals

    International Nuclear Information System (INIS)

    Jeavons, A.P.; Chandler, R.A.; Dettmar, C.A.R.

    1999-01-01

    A HIDAC-PET camera consisting essentially of 5 million 0.5 mm gas avalanching detectors has been constructed for small-animal imaging. The particular HIDAC advantage--a high 3D spatial resolution--has been improved to 0.95 mm fwhm and to 0.7 mm fwhm when reconstructing with 3D-OSEM methods incorporating resolution recovery. A depth-of-interaction resolution of 2.5 mm is implicit, due to the laminar construction. Scatter-corrected sensitivity, at 8.9 cps/kBq (i.e. 0.9%) from a central point source, or 7.2 cps/kBq (543 cps/kBq/cm 3 ) from a distributed (40 mm diameter, 60 mm long) source is now much higher than previous, and other, work. A field-of-view of 100 mm (adjustable to 200 mm) diameter by 210 mm axially permits whole-body imaging of small animals, containing typically 4MBqs of activity, at 40 kcps of which 16% are random coincidences, with a typical scatter fraction of 44%. Throughout the field-of-view there are no positional distortions and relative quantitation is uniform to ± 3.5%, but some variation of spatial resolution is found. The performance demonstrates that HIDAC technology is quite appropriate for small-animal PET cameras

  7. Scalable electrophysiology in intact small animals with nanoscale suspended electrode arrays

    Science.gov (United States)

    Gonzales, Daniel L.; Badhiwala, Krishna N.; Vercosa, Daniel G.; Avants, Benjamin W.; Liu, Zheng; Zhong, Weiwei; Robinson, Jacob T.

    2017-07-01

    Electrical measurements from large populations of animals would help reveal fundamental properties of the nervous system and neurological diseases. Small invertebrates are ideal for these large-scale studies; however, patch-clamp electrophysiology in microscopic animals typically requires invasive dissections and is low-throughput. To overcome these limitations, we present nano-SPEARs: suspended electrodes integrated into a scalable microfluidic device. Using this technology, we have made the first extracellular recordings of body-wall muscle electrophysiology inside an intact roundworm, Caenorhabditis elegans. We can also use nano-SPEARs to record from multiple animals in parallel and even from other species, such as Hydra littoralis. Furthermore, we use nano-SPEARs to establish the first electrophysiological phenotypes for C. elegans models for amyotrophic lateral sclerosis and Parkinson's disease, and show a partial rescue of the Parkinson's phenotype through drug treatment. These results demonstrate that nano-SPEARs provide the core technology for microchips that enable scalable, in vivo studies of neurobiology and neurological diseases.

  8. 9.4 T small animal MRI using clinical components for direct translational studies.

    Science.gov (United States)

    Felder, Jörg; Celik, A Avdo; Choi, Chang-Hoon; Schwan, Stefan; Shah, N Jon

    2017-12-28

    Magnetic resonance is a major preclinical and clinical imaging modality ideally suited for longitudinal studies, e.g. in pharmacological developments. The lack of a proven platform that maintains an identical imaging protocol between preclinical and clinical platforms is solved with the construction of an animal scanner based on clinical hard- and software. A small animal magnet and gradient system were connected to a clinical MR system. Several hardware components were either modified or built in-house to achieve compatibility. The clinical software was modified to account for the different field-of-view of a preclinical MR system. The established scanner was evaluated using clinical QA protocols, and platform compatibility for translational research was verified against clinical scanners of different field strength. The constructed animal scanner operates with the majority of clinical imaging sequences. Translational research is greatly facilitated as protocols can be shared between preclinical and clinical platforms. Hence, when maintaining sequences parameters, maximum similarity between pulses played out on a human or an animal system is maintained. Coupling of a small animal magnet with a clinical MR system is a flexible, easy to use way to establish and advance translational imaging capability. It provides cost and labor efficient translational capability as no tedious sequence reprogramming between moieties is required and cross-platform compatibility of sequences facilitates multi-center studies.

  9. New experimental model for single liver lobe hyperthermia in small animals using non-directional microwaves.

    Directory of Open Access Journals (Sweden)

    Ionuț Tudorancea

    Full Text Available Our aim was to develop a new experimental model for in vivo hyperthermia using non-directional microwaves, applicable to small experimental animals. We present an affordable approach for targeted microwave heat delivery to an isolated liver lobe in rat, which allows rapid, precise and stable tissue temperature control.A new experimental model is proposed. We used a commercial available magnetron generating 2450 MHz, with 4.4V and 14A in the filament and 4500V anodic voltage. Modifications were required in order to adjust tissue heating such as to prevent overheating and to allow for fine adjustments according to real-time target temperature. The heating is controlled using a virtual instrument application implemented in LabView® and responds to 0.1° C variations in the target. Ten healthy adult male Wistar rats, weighing 250-270 g were used in this study. The middle liver lobe was the target for controlled heating, while the rest of the living animal was protected.In vivo microwave delivery using our experimental setting is safe for the animals. Target tissue temperature rises from 30°C to 40°C with 3.375°C / second (R2 = 0.9551, while the increment is lower it the next two intervals (40-42°C and 42-44°C with 0.291°C/ s (R2 = 0.9337 and 0.136°C/ s (R2 = 0.7894 respectively, when testing in sequences. After reaching the desired temperature, controlled microwave delivery insures a very stable temperature during the experiments.We have developed an inexpensive and easy to manufacture system for targeted hyperthermia using non-directional microwave radiation. This system allows for fine and stable temperature adjustments within the target tissue and is ideal for experimental models testing below or above threshold hyperthermia.

  10. Giardia survey in live-trapped small domestic and wild mammals in four regions in the southwest region of the State of São Paulo, Brazil

    Directory of Open Access Journals (Sweden)

    Maria Inês L. Sogayar

    1995-12-01

    Full Text Available For the first time, a survey on Giardia in the live-trapped small domestic and wild mammals was perfomed in four regions of state of the São Paulo, Brazil, with special attention to the parasitism of Rattus rattus rattus by Giardia. This species was found infected in all studied sites: Botucatu (15.4%, Conchas (28.5%, Itaporanga (38.7% and São Roque (100 %. Two new hosts and their frequency of infection were described for Giardia in Nectomys squamipes, an aquatic rodent and in Bolomys lasiurus, a forest rodent (100 % and 14.3 %, respectively. Both G. muris and G. duodenalis groups were found in scrapings of intestinal mucosa of those rodents. Mixed infection was observed in some animals. It is important to emphasize the infection by G. duodenalis in the black rat as this species lives as a comensal with man and in N. squamipes as it may contaminate small streams used for domestic consumption. Therefore, further investigation will be necessary to elucidate the potential of these rodents to act as reservoirs of Giardia for man.

  11. In vivo fluorescence enhanced optical tomography reconstruction of lung cancer of non immersed small animals

    Science.gov (United States)

    Hervé, L.; Koenig, A.; Da Silva, A.; Berger, M.; Boutet, J.; Dinten, J. M.; Peltié, P.; Rizo, P.

    2007-02-01

    Fluorescence enhanced diffuse optical tomography (fDOT) is envisioned to be useful to collect functional information from small animal models. For oncology applications, cancer-targeted fluorescent markers can be used as a surrogate of the cancer activity. We are developing a continuous wave fDOT bench intended to be integrated in systems dedicated to whole body small animal fluorescence analyses. The focus is currently put on the reconstruction of non immersed small animals imaged by a CCD camera. The reconstruction stage already corrects the tissue heterogeneity artifacts through the computation of an optical heterogeneity map. We will show how this formalism coupled with the determination of the animal boundaries performed by a laser scanner, can be used to manage non contact acquisitions. The time of reconstruction for a 10 × 9 laser source positions, 45 × 40 detector elements and 14 × 11 × 14 mesh voxels is typically 10 minutes on a 3GHz PCs corresponding to the acquisition time allowing the two tasks to be performed in parallel. The system is validated on an in vivo experiment performed on three healthy nude mice and a mouse bearing a lung tumor at 10, 12 and 14 days after implantation allowing the follow up of the disease. The 3D fluorescence reconstructions of this mouse are presented and the total fluorescence amounts are compared.

  12. Using ground penetrating radar in levee assessment to detect small scale animal burrows

    Science.gov (United States)

    Chlaib, Hussein K.; Mahdi, Hanan; Al-Shukri, Haydar; Su, Mehmet M.; Catakli, Aycan; Abd, Najah

    2014-04-01

    Levees are civil engineering structures built to protect human lives, property, and agricultural lands during flood events. To keep these important structures in a safe condition, continuous monitoring must be performed regularly and thoroughly. Small rodent burrows are one of the major defects within levees; however, their early detection and repair helps in protecting levees during flooding events. A set of laboratory experiments was conducted to analyze the polarity change in GPR signals in the presence of subsurface voids and water-filled cavities. Ground Penetrating Radar (GPR) surveys using multi frequency antennas (400 MHz and 900 MHz) were conducted along an 875 meter section of the Lollie Levee near Conway, Arkansas, USA, to assess the levee's structural integrity. Many subsurface animal burrows, water-filled cavities, clay clasts, and metallic objects were investigated and identified. These anomalies were located at different depths and have different sizes. To ground truth the observations, hand dug trenches were excavated to confirm several anomalies. Results show an excellent match between GPR interpreted anomalies and the observed features. In-situ dielectric constant measurements were used to calculate the feature depths. The results of this research show that the 900 MHz antenna has more advantages over the 400 MHz antenna.

  13. First application of liquid-metal-jet sources for small-animal imaging: High-resolution CT and phase-contrast tumor demarcation

    Energy Technology Data Exchange (ETDEWEB)

    Larsson, Daniel H.; Lundstroem, Ulf; Burvall, Anna; Hertz, Hans M. [Department of Applied Physics, KTH Royal Institute of Technology/Albanova, 10691 Stockholm (Sweden); Westermark, Ulrica K.; Arsenian Henriksson, Marie [Department of Microbiology, Tumor and Cell Biology (MTC), Karolinska Institutet, 17177 Stockholm (Sweden)

    2013-02-15

    Purpose: Small-animal studies require images with high spatial resolution and high contrast due to the small scale of the structures. X-ray imaging systems for small animals are often limited by the microfocus source. Here, the authors investigate the applicability of liquid-metal-jet x-ray sources for such high-resolution small-animal imaging, both in tomography based on absorption and in soft-tissue tumor imaging based on in-line phase contrast. Methods: The experimental arrangement consists of a liquid-metal-jet x-ray source, the small-animal object on a rotating stage, and an imaging detector. The source-to-object and object-to-detector distances are adjusted for the preferred contrast mechanism. Two different liquid-metal-jet sources are used, one circulating a Ga/In/Sn alloy and the other an In/Ga alloy for higher penetration through thick tissue. Both sources are operated at 40-50 W electron-beam power with {approx}7 {mu}m x-ray spots, providing high spatial resolution in absorption imaging and high spatial coherence for the phase-contrast imaging. Results: High-resolution absorption imaging is demonstrated on mice with CT, showing 50 {mu}m bone details in the reconstructed slices. High-resolution phase-contrast soft-tissue imaging shows clear demarcation of mm-sized tumors at much lower dose than is required in absorption. Conclusions: This is the first application of liquid-metal-jet x-ray sources for whole-body small-animal x-ray imaging. In absorption, the method allows high-resolution tomographic skeletal imaging with potential for significantly shorter exposure times due to the power scalability of liquid-metal-jet sources. In phase contrast, the authors use a simple in-line arrangement to show distinct tumor demarcation of few-mm-sized tumors. This is, to their knowledge, the first small-animal tumor visualization with a laboratory phase-contrast system.

  14. A small animal holding fixture system with positional reproducibility for longitudinal multimodal imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kokuryo, Daisuke; Kimura, Yuichi; Obata, Takayuki; Yamaya, Taiga; Kawamura, Kazunori; Zhang, Ming-Rong; Kanno, Iwao; Aoki, Ichio, E-mail: ukimura@ieee.or [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage, Chiba 263-8555 (Japan)

    2010-07-21

    This study presents a combined small animal holding fixture system, termed a 'bridge capsule', which provides for small animal re-fixation with positional reproducibility. This system comprises separate holding fixtures for the head and lower body and a connecting part to a gas anesthesia system. A mouse is fixed in place by the combination of a head fixture with a movable part made from polyacetal resin, a lower body fixture made from vinyl-silicone and a holder for the legs and tail. For re-fixation, a similar posture could be maintained by the same holding fixtures and a constant distance between the head and lower body fixtures is maintained. Artifacts caused by the bridge capsule system were not observed on magnetic resonance (MRI) and positron emission tomography (PET) images. The average position differences of the spinal column and the iliac body before and after re-fixation for the same modality were approximately 1.1 mm. The difference between the MRI and PET images was approximately 1.8 mm for the lower body fixture after image registration using fiducial markers. This system would be useful for longitudinal, repeated and multimodal imaging experiments requiring similar animal postures.

  15. Neurological examination in small animals

    Directory of Open Access Journals (Sweden)

    Viktor Paluš

    2014-03-01

    Full Text Available This clinical review about the neurological examination in small animals describes the basics about the first steps of investigation when dealing with neurological patients. The knowledge of how to perform the neurological examination is important however more important is how to correctly interpret these performed tests. A step-by-step approach is mandatory and examiners should master the order and the style of performing these tests. Neurological conditions can be sometimes very distressing for owners and for pets that might not be the most cooperating. The role of a veterinary surgeon, as a professional, is therefore to collect the most relevant history, to examine a patient in a professional manner and to give to owners an educated opinion about the further treatment and prognosis. However neurological examinations might look challenging for many. But it is only the clinical application of neuroanatomy and neurophysiology to an every-day situation for practicing veterinarians and it does not require any specific in-to-depth knowledge. This clinical review is aimed not only to provide the information on how to perform the neurological examination but it is also aimed to appeal on veterinarians to challenge their daily routine and to start practicing on neurologically normal patients. This is the best and only way to differentiate between the normal and abnormal in a real situation.

  16. Automated analysis of small animal PET studies through deformable registration to an atlas

    NARCIS (Netherlands)

    Gutierrez, Daniel F.; Zaidi, Habib

    This work aims to develop a methodology for automated atlas-guided analysis of small animal positron emission tomography (PET) data through deformable registration to an anatomical mouse model. A non-rigid registration technique is used to put into correspondence relevant anatomical regions of

  17. Animals Alive! An Ecological Guide to Animal Activities.

    Science.gov (United States)

    Holley, Dennis

    Animals Alive! is designed to help teachers develop an inquiry-oriented program for studying the animal kingdom in which, whenever possible, live animals are collected locally, studied, observed, and then released completely unharmed back into their natural habitats. By careful selection and modification of the chapter questions, activities, and…

  18. Small prey species' behaviour and welfare: implications for veterinary professionals.

    Science.gov (United States)

    McBride, E Anne

    2017-08-01

    People have obligations to ensure the welfare of animals under their care. Offences under the UK Animal Welfare Act are acts, or failures of action, causing unnecessary suffering. Veterinary professionals need to be able to provide current, scientifically based prophylactic advice, and respect the limits of their expertise. The ethical concept of a life worth living and the Five Freedoms are core to welfare. Behaviour is a central component, both influencing and influenced by physical health. Owners frequently misunderstand the behaviour of small prey mammals and how to meet their needs. This review provides insight into the physical-social (external) and the cognitive-emotional (internal) environments of small prey mammals, contextualised within an evolutionary perspective. This is extrapolated to captivity and practical suggestions given for meeting behavioural freedoms and enhancing client understanding and enjoyment of their animals, thereby improving welfare. © 2017 British Small Animal Veterinary Association.

  19. X-ray micro-tomography system for small-animal imaging with zoom-in imaging capability

    International Nuclear Information System (INIS)

    Chun, In Kon; Cho, Myung Hye; Lee, Sang Chul; Cho, Min Hyoung; Lee, Soo Yeol

    2004-01-01

    Since a micro-tomography system capable of μm-resolution imaging cannot be used for whole-body imaging of a small laboratory animal without sacrificing its spatial resolution, it is desirable for a micro-tomography system to have local imaging capability. In this paper, we introduce an x-ray micro-tomography system capable of high-resolution imaging of a local region inside a small animal. By combining two kinds of projection data, one from a full field-of-view (FOV) scan of the whole body and the other from a limited FOV scan of the region of interest (ROI), we have obtained zoomed-in images of the ROI without any contrast anomalies commonly appearing in conventional local tomography. For experimental verification of the zoom-in imaging capability, we have integrated a micro-tomography system using a micro-focus x-ray source, a 1248 x 1248 flat-panel x-ray detector, and a precision scan mechanism. The mismatches between the two projection data caused by misalignments of the scan mechanism have been estimated with a calibration phantom, and the mismatch effects have been compensated in the image reconstruction procedure. Zoom-in imaging results of bony tissues with a spatial resolution of 10 lp mm -1 suggest that zoom-in micro-tomography can be greatly used for high-resolution imaging of a local region in small-animal studies

  20. Reducing animal experimentation in foot-and-mouth disease vaccine potency tests.

    Science.gov (United States)

    Reeve, Richard; Cox, Sarah; Smitsaart, Eliana; Beascoechea, Claudia Perez; Haas, Bernd; Maradei, Eduardo; Haydon, Daniel T; Barnett, Paul

    2011-07-26

    The World Organisation for Animal Health (OIE) Terrestrial Manual and the European Pharmacopoeia (EP) still prescribe live challenge experiments for foot-and-mouth disease virus (FMDV) immunogenicity and vaccine potency tests. However, the EP allows for other validated tests for the latter, and specifically in vitro tests if a "satisfactory pass level" has been determined; serological replacements are also currently in use in South America. Much research has therefore focused on validating both ex vivo and in vitro tests to replace live challenge. However, insufficient attention has been given to the sensitivity and specificity of the "gold standard"in vivo test being replaced, despite this information being critical to determining what should be required of its replacement. This paper aims to redress this imbalance by examining the current live challenge tests and their associated statistics and determining the confidence that we can have in them, thereby setting a standard for candidate replacements. It determines that the statistics associated with the current EP PD(50) test are inappropriate given our domain knowledge, but that the OIE test statistics are satisfactory. However, it has also identified a new set of live animal challenge test regimes that provide similar sensitivity and specificity to all of the currently used OIE tests using fewer animals (16 including controls), and can also provide further savings in live animal experiments in exchange for small reductions in sensitivity and specificity. Copyright © 2011 Elsevier Ltd. All rights reserved.

  1. Pain control in small animalsControle da dor em pequenos animais

    Directory of Open Access Journals (Sweden)

    Julia Duarte Penter

    2011-12-01

    Full Text Available Pain is an unpleasant sensory or emotional experience that follows the application of a noxious stimulus. Can be experienced with or without the concomitant occurrence of physical stress signs, which occurs frequently in animals caused by trauma, systemic disease or surgical procedures. The control depends on length, where there are painful impulses and mental status of the animal. It is an important clinical condition, resulting in suffer that will affect quality life. This paper is a review of pathophysiology and pain control in small animals.A dor é uma experiência sensorial ou emocional desagradável que se segue à aplicação de um estímulo nocivo. Pode ser vivenciada com ou sem o acontecimento concomitante de sinais físicos de estresse, trauma, doença sistêmica ou procedimento cirúrgico. Seu controle depende de sua duração, de onde surgem os impulsos dolorosos e do estado de consciência do animal. É uma condição clinicamente importante, que resulta em sofrimento e afeta a qualidade de vida dos animais. O objetivo deste trabalho é a revisão da fisiopatologia e controle da dor em pequenos animais.

  2. Small animal positron emission tomography imaging and in vivo studies of atherosclerosis

    DEFF Research Database (Denmark)

    Hag, Anne Mette Fisker; Ripa, Rasmus Sejersten; Pedersen, Sune Folke

    2013-01-01

    Atherosclerosis is a growing health challenge globally, and despite our knowledge of the disease has increased over the last couple of decades, many unanswered questions remain. As molecular imaging can be used to visualize, characterize and measure biological processes at the molecular and cellu...... knowledge obtained from in vivo positron emission tomography studies of atherosclerosis performed in small animals....

  3. Development of computational small animal models and their applications in preclinical imaging and therapy research.

    Science.gov (United States)

    Xie, Tianwu; Zaidi, Habib

    2016-01-01

    The development of multimodality preclinical imaging techniques and the rapid growth of realistic computer simulation tools have promoted the construction and application of computational laboratory animal models in preclinical research. Since the early 1990s, over 120 realistic computational animal models have been reported in the literature and used as surrogates to characterize the anatomy of actual animals for the simulation of preclinical studies involving the use of bioluminescence tomography, fluorescence molecular tomography, positron emission tomography, single-photon emission computed tomography, microcomputed tomography, magnetic resonance imaging, and optical imaging. Other applications include electromagnetic field simulation, ionizing and nonionizing radiation dosimetry, and the development and evaluation of new methodologies for multimodality image coregistration, segmentation, and reconstruction of small animal images. This paper provides a comprehensive review of the history and fundamental technologies used for the development of computational small animal models with a particular focus on their application in preclinical imaging as well as nonionizing and ionizing radiation dosimetry calculations. An overview of the overall process involved in the design of these models, including the fundamental elements used for the construction of different types of computational models, the identification of original anatomical data, the simulation tools used for solving various computational problems, and the applications of computational animal models in preclinical research. The authors also analyze the characteristics of categories of computational models (stylized, voxel-based, and boundary representation) and discuss the technical challenges faced at the present time as well as research needs in the future.

  4. Development of computational small animal models and their applications in preclinical imaging and therapy research

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Tianwu [Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva 4 CH-1211 (Switzerland); Zaidi, Habib, E-mail: habib.zaidi@hcuge.ch [Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva 4 CH-1211 (Switzerland); Geneva Neuroscience Center, Geneva University, Geneva CH-1205 (Switzerland); Department of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Groningen 9700 RB (Netherlands)

    2016-01-15

    The development of multimodality preclinical imaging techniques and the rapid growth of realistic computer simulation tools have promoted the construction and application of computational laboratory animal models in preclinical research. Since the early 1990s, over 120 realistic computational animal models have been reported in the literature and used as surrogates to characterize the anatomy of actual animals for the simulation of preclinical studies involving the use of bioluminescence tomography, fluorescence molecular tomography, positron emission tomography, single-photon emission computed tomography, microcomputed tomography, magnetic resonance imaging, and optical imaging. Other applications include electromagnetic field simulation, ionizing and nonionizing radiation dosimetry, and the development and evaluation of new methodologies for multimodality image coregistration, segmentation, and reconstruction of small animal images. This paper provides a comprehensive review of the history and fundamental technologies used for the development of computational small animal models with a particular focus on their application in preclinical imaging as well as nonionizing and ionizing radiation dosimetry calculations. An overview of the overall process involved in the design of these models, including the fundamental elements used for the construction of different types of computational models, the identification of original anatomical data, the simulation tools used for solving various computational problems, and the applications of computational animal models in preclinical research. The authors also analyze the characteristics of categories of computational models (stylized, voxel-based, and boundary representation) and discuss the technical challenges faced at the present time as well as research needs in the future.

  5. Development of computational small animal models and their applications in preclinical imaging and therapy research

    International Nuclear Information System (INIS)

    Xie, Tianwu; Zaidi, Habib

    2016-01-01

    The development of multimodality preclinical imaging techniques and the rapid growth of realistic computer simulation tools have promoted the construction and application of computational laboratory animal models in preclinical research. Since the early 1990s, over 120 realistic computational animal models have been reported in the literature and used as surrogates to characterize the anatomy of actual animals for the simulation of preclinical studies involving the use of bioluminescence tomography, fluorescence molecular tomography, positron emission tomography, single-photon emission computed tomography, microcomputed tomography, magnetic resonance imaging, and optical imaging. Other applications include electromagnetic field simulation, ionizing and nonionizing radiation dosimetry, and the development and evaluation of new methodologies for multimodality image coregistration, segmentation, and reconstruction of small animal images. This paper provides a comprehensive review of the history and fundamental technologies used for the development of computational small animal models with a particular focus on their application in preclinical imaging as well as nonionizing and ionizing radiation dosimetry calculations. An overview of the overall process involved in the design of these models, including the fundamental elements used for the construction of different types of computational models, the identification of original anatomical data, the simulation tools used for solving various computational problems, and the applications of computational animal models in preclinical research. The authors also analyze the characteristics of categories of computational models (stylized, voxel-based, and boundary representation) and discuss the technical challenges faced at the present time as well as research needs in the future

  6. The Combination of In vivo 124I-PET and CT Small Animal Imaging for Evaluation of Thyroid Physiology and Dosimetry

    Directory of Open Access Journals (Sweden)

    Henrik H. El-Ali

    2012-06-01

    Full Text Available Objective: A thyroid rat model combining functional and anatomical information would be of great benefit for better modeling of thyroid physiology and for absorbed dose calculations. Our aim was to show that 124I-PET and CT small animal imaging are useful as a combined model for studying thyroid physiology and dose calculation. Methods: Seven rats were subjects for multiple thyroid 124I-imaging and CT-scans. S-values [mGy/MBqs] for different thyroid sizes were simulated. A phantom with spheres was designed for validation of performances of the small animal PET and CT imaging systems. Results: Small animal image-based measurements of the activity amount and the volumes of the spheres with a priori known volumes showed a good agreement with their corresponding actual volumes. The CT scans of the rats showed thyroid volumes from 34–70 mL. Conclusions: The wide span in volumes of thyroid glands indicates the importance of using an accurate volume-measuring technique such as the small animal CT. The small animal PET system was on the other hand able to accurately estimate the activity concentration in the thyroid volumes. We conclude that the combination of the PET and CT image information is essential for quantitative thyroid imaging and accurate thyroid absorbed dose calculation.

  7. STTARR: a radiation treatment and multi-modal imaging facility for fast tracking novel agent development in small animal models

    International Nuclear Information System (INIS)

    Yeung, Ivan; McKee, Trevor; Jaffray, David; Hill, Richard

    2014-01-01

    Small animal models play a pivotal role in the pipeline development of novel agents and strategies in personalized cancer therapy. The Spatio-Temporal Targeting and Amplification of Radiation Response Program (STTARR) consists of an animal imaging and precision radiation facility designed to provide innovative biologic imaging and targeted radiation treatment strategies in small animals. The design is to mirror the imaging and radiation treatment facility in a modern cancer center. The STTARR features imaging equipment of small animal scale including CT, MRI, PET, SPECT, Optical devices as well as image guided irradiators. The fleet of imaging and irradiation equipment provides a platform for identification of biological targets of the specific molecular pathways that influence both tumor progression and a patient's response to radiation therapy. Examples will be given in the utilization of the imaging facilities for development in novel approaches in cancer therapy including a PET-FAZA study for hypoxia measurement in a pancreatic adenocarcinoma xenograft model. In addition, the cone-beam image guided small animal irradiator developed at our institute will also be described. The animal platform (couch) provides motion in 3 dimensions to position the animal to the isocentre of the beam. A pair of rotational arms supporting the X-ray/detector pair enables acquisition of cone-beam images of the animal which give rise to image guided precision of 0.5 mm. The irradiation energy ranges from 50 to 225 kVp at a dose rate from 10-400 cGy/min. The gantry is able to direct X-ray beam of different directions to give conformal radiation treatment to the animal. A dedicated treatment planning system is able to perform treatment planning and provide commonly used clinical metrics in the animal treatment plan. Examples will be given to highlight the use of the image guided irradiator for research of drug/irradiation regimen in animal models. (author)

  8. Anesthesia condition for {sup 18}F-FDG imaging of lung metastasis tumors using small animal PET

    Energy Technology Data Exchange (ETDEWEB)

    Woo, Sang-Keun; Lee, Tae Sup; Kim, Kyeong Min; Kim, June-Youp; Jung, Jae Ho; Kang, Joo Hyun [Division of Nuclear Medicine and RI Application, Korea Institute of Radiological and Medical Sciences (KIRAMS), Nowon-Gu, Seoul 139-706 (Korea, Republic of); Cheon, Gi Jeong [Division of Nuclear Medicine and RI Application, Korea Institute of Radiological and Medical Sciences (KIRAMS), Nowon-Gu, Seoul 139-706 (Korea, Republic of); Department of Nuclear Medicine, Korea Institute of Radiological and Medical Sciences (KIRAMS), Nowon-Gu, Seoul 139-706 (Korea, Republic of)], E-mail: larry@kcch.re.kr; Choi, Chang Woon; Lim, Sang Moo [Division of Nuclear Medicine and RI Application, Korea Institute of Radiological and Medical Sciences (KIRAMS), Nowon-Gu, Seoul 139-706 (Korea, Republic of); Department of Nuclear Medicine, Korea Institute of Radiological and Medical Sciences (KIRAMS), Nowon-Gu, Seoul 139-706 (Korea, Republic of)

    2008-01-15

    Small animal positron emission tomography (PET) with {sup 18}F-FDG has been increasingly used for tumor imaging in the murine model. The aim of this study was to establish the anesthesia condition for imaging of lung metastasis tumor using small animal {sup 18}F-FDG PET. Methods: To determine the impact of anesthesia on {sup 18}F-FDG distribution in normal mice, five groups were studied under the following conditions: no anesthesia, ketamine and xylazine (Ke/Xy), 0.5% isoflurane (Iso 0.5), 1% isoflurane (Iso 1) and 2% isoflurane (Iso 2). The ex vivo counting, standard uptake value (SUV) image and glucose SUV of {sup 18}F-FDG in various tissues were evaluated. The {sup 18}F-FDG images in the lung metastasis tumor model were obtained under no anesthesia, Ke/Xy and Iso 0.5, and registered with CT image to clarify the tumor region. Results: Blood glucose concentration and muscle uptake of {sup 18}F-FDG in the Ke/Xy group markedly increased more than in the other groups. The Iso 2 group increased {sup 18}F-FDG uptake in heart compared with the other groups. The Iso 0.5 anesthesized group showed the lowest {sup 18}F-FDG uptake in heart and chest wall. The small size of lung metastasis tumor (2 mm) was clearly visualized by {sup 18}F-FDG image with the Iso 0.5 anesthesia. Conclusion: Small animal {sup 18}F-FDG PET imaging with Iso 0.5 anesthesia was appropriate for the detection of lung metastasis tumor. To acquire {sup 18}F-FDG PET images with small animal PET, the type and level of anesthetic should be carefully considered to be suitable for the visualization of target tissue in the experimental model.

  9. Advances in SPECT Instrumentation (Including Small Animal Scanners). Chapter 4

    International Nuclear Information System (INIS)

    Di Domenico, G.; Zavattini, G.

    2009-01-01

    Fundamental major efforts have been devoted to the development of positron emission tomography (PET) imaging modality over the last few decades. Recently, a novel surge of interest in single photon emission computed tomography (SPECT) technology has occurred, particularly after the introduction of the hybrid SPECT-CT imaging system. This has led to a flourishing of investigations in new types of detectors and collimators, and to more accurate refinement of reconstruction algorithms. Along with SPECT-CT, new, fast gamma cameras have been developed for dedicated cardiac imaging. The existing gap between PET and SPECT in sensitivity and spatial resolution is progressively decreasing, and this trend is particularly apparent in the field of small animal imaging where the most important advances have been reported in SPECT tomographs. An outline of the basic features of SPECT technology, and of recent developments in SPECT instrumentation for both clinical applications and basic biological research on animal models is described. (author)

  10. 78 FR 59624 - Guidance for Industry #223: Small Entity Compliance Guide-Declaring Color Additives in Animal...

    Science.gov (United States)

    2013-09-27

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration 21 CFR Part 501 [Docket No. FDA-2013-D-1088] Guidance for Industry 223: Small Entity Compliance Guide--Declaring Color Additives... industry 223 entitled ``Small Entity Compliance Guide--Declaring Color Additives in Animal Foods.'' This...

  11. Cone Beam X-Ray Luminescence Tomography Imaging Based on KA-FEM Method for Small Animals.

    Science.gov (United States)

    Chen, Dongmei; Meng, Fanzhen; Zhao, Fengjun; Xu, Cao

    2016-01-01

    Cone beam X-ray luminescence tomography can realize fast X-ray luminescence tomography imaging with relatively low scanning time compared with narrow beam X-ray luminescence tomography. However, cone beam X-ray luminescence tomography suffers from an ill-posed reconstruction problem. First, the feasibility of experiments with different penetration and multispectra in small animal has been tested using nanophosphor material. Then, the hybrid reconstruction algorithm with KA-FEM method has been applied in cone beam X-ray luminescence tomography for small animals to overcome the ill-posed reconstruction problem, whose advantage and property have been demonstrated in fluorescence tomography imaging. The in vivo mouse experiment proved the feasibility of the proposed method.

  12. Rules of attraction: The role of bait in small mammal sampling at ...

    African Journals Online (AJOL)

    Baits or lures are commonly used for surveying small mammal communities, not only because they attract large numbers of these animals, but also because they provide sustenance for trapped individuals. In this study we used Sherman live traps with five bait treatments to sample small mammal populations at three ...

  13. Coupler for surgery on small animals

    Science.gov (United States)

    Johnson, J. E., Jr.; Swartz, P. F.

    1979-01-01

    Minicoupler simplifies exchange of fluids with organs of laboratory animals enabling one person to perform surgery on experimental animals such as rats and mice. Innovation eliminates obstructing hands and instruments from areas of surgery.

  14. Absolute quantitative total-body small-animal SPECT with focusing pinholes

    International Nuclear Information System (INIS)

    Wu, Chao; Have, Frans van der; Vastenhouw, Brendan; Beekman, Freek J.; Dierckx, Rudi A.J.O.; Paans, Anne M.J.

    2010-01-01

    In pinhole SPECT, attenuation of the photon flux on trajectories between source and pinholes affects quantitative accuracy of reconstructed images. Previously we introduced iterative methods that compensate for image degrading effects of detector and pinhole blurring, pinhole sensitivity and scatter for multi-pinhole SPECT. The aim of this paper is (1) to investigate the accuracy of the Chang algorithm in rodents and (2) to present a practical Chang-based method using body outline contours obtained with optical cameras. Here we develop and experimentally validate a practical method for attenuation correction based on a Chang first-order method. This approach has the advantage that it is employed after, and therefore independently from, iterative reconstruction. Therefore, no new system matrix has to be calculated for each specific animal. Experiments with phantoms and animals were performed with a high-resolution focusing multi-pinhole SPECT system (U-SPECT-II, MILabs, The Netherlands). This SPECT system provides three additional optical camera images of the animal for each SPECT scan from which the animal contour can be estimated. Phantom experiments demonstrated that an average quantification error of -18.7% was reduced to -1.7% when both window-based scatter correction and Chang correction based on the body outline from optical images were applied. Without scatter and attenuation correction, quantification errors in a sacrificed rat containing sources with known activity ranged from -23.6 to -9.3%. These errors were reduced to values between -6.3 and +4.3% (with an average magnitude of 2.1%) after applying scatter and Chang attenuation correction. We conclude that the modified Chang correction based on body contour combined with window-based scatter correction is a practical method for obtaining small-animal SPECT images with high quantitative accuracy. (orig.)

  15. Laser surgery for selected small animal soft-tissue conditions

    Science.gov (United States)

    Bartels, Kenneth E.

    1991-05-01

    With the acquisition of a Nd:YAG and a CO2 laser in the College of Veterinary Medicine at Oklahoma State University in 1989, over 100 small animal clinical cases have been managed with these modern modalities for surgical excision and tissue vaporization. Most procedures have been for oncologic problems, but inflammatory, infectious, or congenital conditions including vaporization of acral lick 'granulomas,' excision/vaporization of foreign body induced, infected draining tracts, and resection of elongated soft palates have been successfully accomplished. Laser excision or vaporization of both benign and malignant neoplasms have effectively been performed and include feline nasal squamous cell carcinoma, mast cell tumors, and rectal/anal neoplasms. Results to date have been excellent with animals exhibiting little postoperative pain, swelling, and inflammation. Investigations involving application of laser energy for tissue welding of esophageal lacerations and hepatitic interstitial hyperthermia for metastatic colorectal cancer have also shown potential. A review of cases with an emphasis on survival time and postoperative morbidity suggests that carefully planned laser surgical procedures in clinical veterinary practice done with standardized protocols and techniques offer an acceptable means of treating conditions that were previously considered extremely difficult or virtually impossible to perform.

  16. Factors influencing common diagnoses made during first-opinion small-animal consultations in the United Kingdom.

    Science.gov (United States)

    Robinson, N J; Dean, R S; Cobb, M; Brennan, M L

    2016-09-01

    It is currently unclear how frequently a diagnosis is made during small-animal consultations or how much of a role making a diagnosis plays in veterinary decision-making. Understanding more about the diagnostic process will help direct future research towards areas relevant to practicing veterinary surgeons. The aim of this study was to determine the frequency with which a diagnosis was made, classify the types of diagnosis made (and the factors influencing these) and determine which specific diagnoses were made for health problems discussed during small-animal consultations. Data were gathered during real-time direct observation of small-animal consultations in eight practices in the United Kingdom. Data collected included characteristics of the consultation (e.g. consultation type), patient (e.g. breed), and each problem discussed (e.g. new or pre-existing problem). Each problem discussed was classified into one of the following diagnosis types: definitive; working; presumed; open; previous. A three-level multivariable logistic-regression model was developed, with problem (Level 1) nested within patient (Level 2) nested within consulting veterinary surgeon (Level 3). Problems without a previous diagnosis, in cats and dogs only, were included in the model, which had a binary outcome variable of definitive diagnosis versus no definitive diagnosis. Data were recorded for 1901 animals presented, and data on diagnosis were gathered for 3192 health problems. Previous diagnoses were the most common diagnosis type (n=1116/3192; 35.0%), followed by open (n=868/3192; 27.2%) then definitive (n=660/3192; 20.7%). The variables remaining in the final model were patient age, problem history, consultation type, who raised the problem, and body system affected. New problems, problems in younger animals, and problems raised by the veterinary surgeon were more likely to result in a definitive diagnosis than pre-existing problems, problems in older animals, and problems raised by

  17. [Skills lab training in veterinary medicine. Effective preparation for clinical work at the small animal clinic of the University for Veterinary Medicine Hannover, Foundation].

    Science.gov (United States)

    Engelskirchen, Simon; Ehlers, Jan; Kirk, Ansgar T; Tipold, Andrea; Dilly, Marc

    2017-09-20

    During five and a half years of studying veterinary medicine, students should in addition to theoretical knowledge acquire sufficient practical skills. Considering animal welfare and ethical aspects, opportunities for hands-on learning on living animals are limited because of the high annual number of students. The first German veterinary clinical-skills lab, established in 2013 at the University for Veterinary Medicine Hannover, Foundation (TiHo), offers opportunities for all students to learn, train and repeat clinical skills on simulators and models as frequently as they would like, until they feel sufficiently confident to transfer these skills to living animals. This study describes the establishment of clinical-skills lab training within the students' practical education, using the example of the small-animal clinic of the TiHo. Two groups of students were compared: without skills lab training (control group K) and with skills lab training (intervention group I). At the end of both the training and a subsequent 10-week clinical rotation in different sections of the clinic, an objective structured clinical examination (OSCE) was performed, testing the students' practical skills at 15 stations. An additional multiple-choice test was performed before and after the clinical rotation to evaluate the increased theoretical knowledge. Students of group I achieved significantly (p ≤ 0.05) better results in eight of the 15 tested skills. The multiple-choice test revealed a significant (p ≤ 0.05) gain of theoretical knowledge in both groups without any differences between the groups. Students displayed a high degree of acceptance of the skills lab training. Using simulators and models in veterinary education is an efficient teaching concept, and should be used continually and integrated in the curriculum.

  18. Prediction of retail beef yield and fat content from live animal and carcass measurements in Nellore cattle.

    Science.gov (United States)

    Sakamoto, L S; Mercadante, M E Z; Bonilha, S F M; Branco, R H; Bonilha, E F M; Magnani, E

    2014-11-01

    Data from 156 Nellore males were used to develop equations for the prediction of retail beef yield and carcass fat content, expressed as kilograms and as a percentage, from live animal and carcass measurements. Longissimus muscle area and backfat and rump fat thickness were measured by ultrasound up to 5 d before slaughter and fasted live weight was determined 1 d before slaughter. The same traits were obtained after slaughter. The carcass edible portion (CEP in kg and CEP% in percentage; n = 116) was calculated by the sum of the edible portions of primal cuts: hindquarter, forequarter, and spare ribs. Trimmable fat from the carcass boning process, with the standardization of about 3 mm of fat on retail beef, was considered to be representative of carcass fat content. Most of the variation in CEP was explained by fasted live weight or carcass weight (R(2) of 0.92 and 0.96); the same occurred for CEP% (R(2) of 0.15 and 0.13), and for CEP, the inclusion of LM area and fat thickness reduced the equation bias (lower value of Mallow's Cp statistics). For trimmable fat, most variation could be explained by weight or rump fat thickness. In general, the equations developed from live animal measurements showed a predictive power similar to the equations using carcass measurements. In all cases, the traits expressed as kilograms were better predicted (R(2) of 0.39 to 0.96) than traits expressed as a percentage (R(2) of 0.08 to 0.42).

  19. METHOD FOR SIMULTANEOUS 90SR AND 137CS IN-VIVO MEASUREMENTS OF SMALL ANIMALS AND OTHER ENVIRONMENTAL MEDIA DEVELOPED FOR THE CONDITIONS OF THE CHERNOBYL EXCLUSION ZONE

    Energy Technology Data Exchange (ETDEWEB)

    Farfan, E.; Jannik, T.

    2011-10-01

    To perform in vivo simultaneous measurements of the {sup 90}Sr and {sup 137}Cs content in the bodies of animals living in the Chernobyl Exclusion Zone (ChEZ), an appropriate method and equipment were developed and installed in a mobile gamma beta spectrometry laboratory. This technique was designed for animals of relatively small sizes (up to 50 g). The {sup 90}Sr content is measured by a beta spectrometer with a 0.1 mm thick scintillation plastic detector. The spectrum processing takes into account the fact that the measured object is 'thick-layered' and contains a comparable quantity of {sup 137}Cs, which is a characteristic condition of the ChEZ. The {sup 137}Cs content is measured by a NaI scintillation detector that is part of the combined gamma beta spectrometry system. For environmental research performed in the ChEZ, the advantages of this method and equipment (rapid measurements, capability to measure live animals directly in their habitat, and the capability of simultaneous {sup 90}Sr and {sup 137}Cs measurements) far outweigh the existing limitations (considerations must be made for background radiation and the animal size, skeletal shape and body mass). The accuracy of these in vivo measurements is shown to be consistent with standard spectrometric and radiochemical methods. Apart from the in vivo measurements, the proposed methodology, after a very simple upgrade that is also described in the article, works even more accurately with samples of other media, such as soil and plants.

  20. WE-H-206-02: Recent Advances in Multi-Modality Molecular Imaging of Small Animals

    Energy Technology Data Exchange (ETDEWEB)

    Tsui, B. [Johns Hopkins University (United States)

    2016-06-15

    Lihong V. Wang: Photoacoustic tomography (PAT), combining non-ionizing optical and ultrasonic waves via the photoacoustic effect, provides in vivo multiscale functional, metabolic, and molecular imaging. Broad applications include imaging of the breast, brain, skin, esophagus, colon, vascular system, and lymphatic system in humans or animals. Light offers rich contrast but does not penetrate biological tissue in straight paths as x-rays do. Consequently, high-resolution pure optical imaging (e.g., confocal microscopy, two-photon microscopy, and optical coherence tomography) is limited to penetration within the optical diffusion limit (∼1 mm in the skin). Ultrasonic imaging, on the contrary, provides fine spatial resolution but suffers from both poor contrast in early-stage tumors and strong speckle artifacts. In PAT, pulsed laser light penetrates tissue and generates a small but rapid temperature rise, which induces emission of ultrasonic waves due to thermoelastic expansion. The ultrasonic waves, orders of magnitude less scattering than optical waves, are then detected to form high-resolution images of optical absorption at depths up to 7 cm, conquering the optical diffusion limit. PAT is the only modality capable of imaging across the length scales of organelles, cells, tissues, and organs (up to whole-body small animals) with consistent contrast. This rapidly growing technology promises to enable multiscale biological research and accelerate translation from microscopic laboratory discoveries to macroscopic clinical practice. PAT may also hold the key to label-free early detection of cancer by in vivo quantification of hypermetabolism, the quintessential hallmark of malignancy. Learning Objectives: To understand the contrast mechanism of PAT To understand the multiscale applications of PAT Benjamin M. W. Tsui: Multi-modality molecular imaging instrumentation and techniques have been major developments in small animal imaging that has contributed significantly

  1. WE-H-206-02: Recent Advances in Multi-Modality Molecular Imaging of Small Animals

    International Nuclear Information System (INIS)

    Tsui, B.

    2016-01-01

    Lihong V. Wang: Photoacoustic tomography (PAT), combining non-ionizing optical and ultrasonic waves via the photoacoustic effect, provides in vivo multiscale functional, metabolic, and molecular imaging. Broad applications include imaging of the breast, brain, skin, esophagus, colon, vascular system, and lymphatic system in humans or animals. Light offers rich contrast but does not penetrate biological tissue in straight paths as x-rays do. Consequently, high-resolution pure optical imaging (e.g., confocal microscopy, two-photon microscopy, and optical coherence tomography) is limited to penetration within the optical diffusion limit (∼1 mm in the skin). Ultrasonic imaging, on the contrary, provides fine spatial resolution but suffers from both poor contrast in early-stage tumors and strong speckle artifacts. In PAT, pulsed laser light penetrates tissue and generates a small but rapid temperature rise, which induces emission of ultrasonic waves due to thermoelastic expansion. The ultrasonic waves, orders of magnitude less scattering than optical waves, are then detected to form high-resolution images of optical absorption at depths up to 7 cm, conquering the optical diffusion limit. PAT is the only modality capable of imaging across the length scales of organelles, cells, tissues, and organs (up to whole-body small animals) with consistent contrast. This rapidly growing technology promises to enable multiscale biological research and accelerate translation from microscopic laboratory discoveries to macroscopic clinical practice. PAT may also hold the key to label-free early detection of cancer by in vivo quantification of hypermetabolism, the quintessential hallmark of malignancy. Learning Objectives: To understand the contrast mechanism of PAT To understand the multiscale applications of PAT Benjamin M. W. Tsui: Multi-modality molecular imaging instrumentation and techniques have been major developments in small animal imaging that has contributed significantly

  2. A 3D high-resolution gamma camera for radiopharmaceutical studies with small animals

    CERN Document Server

    Loudos, G K; Giokaris, N D; Styliaris, E; Archimandritis, S C; Varvarigou, A D; Papanicolas, C N; Majewski, S; Weisenberger, D; Pani, R; Scopinaro, F; Uzunoglu, N K; Maintas, D; Stefanis, K

    2003-01-01

    The results of studies conducted with a small field of view tomographic gamma camera based on a Position Sensitive Photomultiplier Tube are reported. The system has been used for the evaluation of radiopharmaceuticals in small animals. Phantom studies have shown a spatial resolution of 2 mm in planar and 2-3 mm in tomographic imaging. Imaging studies in mice have been carried out both in 2D and 3D. Conventional radiopharmaceuticals have been used and the results have been compared with images from a clinically used system.

  3. Evaluation of 3D reconstruction algorithms for a small animal PET camera

    International Nuclear Information System (INIS)

    Johnson, C.A.; Gandler, W.R.; Seidel, J.

    1996-01-01

    The use of paired, opposing position-sensitive phototube scintillation cameras (SCs) operating in coincidence for small animal imaging with positron emitters is currently under study. Because of the low sensitivity of the system even in 3D mode and the need to produce images with high resolution, it was postulated that a 3D expectation maximization (EM) reconstruction algorithm might be well suited for this application. We investigated four reconstruction algorithms for the 3D SC PET camera: 2D filtered back-projection (FBP), 2D ordered subset EM (OSEM), 3D reprojection (3DRP), and 3D OSEM. Noise was assessed for all slices by the coefficient of variation in a simulated uniform cylinder. Resolution was assessed from a simulation of 15 point sources in the warm background of the uniform cylinder. At comparable noise levels, the resolution achieved with OSEM (0.9-mm to 1.2-mm) is significantly better than that obtained with FBP or 3DRP (1.5-mm to 2.0-mm.) Images of a rat skull labeled with 18 F-fluoride suggest that 3D OSEM can improve image quality of a small animal PET camera

  4. Trap-induced mass declines in small mammals: Mass as a population index

    Science.gov (United States)

    Dean E. Pearson; Yvette K. Ortega; Leonard F. Ruggiero

    2003-01-01

    Body mass is routinely used as an index of physical condition for comparing small-mammal populations. However, trapping effects on animals may undermine the effectiveness of body mass as an index of population health. We examined the effects of live-trapping on body mass of 3 small-mammal species: deer mice (Peromyscus maniculatus), southern red-...

  5. Radiolabeling small RNA with technetium-99m for visualizing cellular delivery and mouse biodistribution

    International Nuclear Information System (INIS)

    Liu Ning; Ding Hongliu; Vanderheyden, Jean-Luc; Zhu Zhihong; Zhang Yumin

    2007-01-01

    To develop a noninvasive direct method for the in vivo tracking of small interfering RNA (siRNA) used in RNA interference, two 18-nucleotide oligoribonucleotides were radiolabeled with technetium-99m ( 99m Tc-RNA). The ability of 99m Tc-RNA to track delivery was tested in cultured cells and living mice. The cellular delivery of 99m Tc-RNAs could be quantified by gamma counting and could be visualized by microautoradiography. Radiolabeled RNAs can be efficiently delivered into cells by reaching up to 3x10 5 molecules of small RNAs per cell. Moreover, RNAs were internalized with homogeneous distribution throughout the cytoplasm and nucleus. In tumor-bearing mice, whole-body images and biodistribution studies showed that 99m Tc-RNAs were delivered to almost all tissues after intravenous injection. The imaging of living animals allowed noninvasive and longitudinal monitoring of the in vivo delivery of these small RNAs. In conclusion, using 99m Tc radiolabeling, the delivery of small RNAs could be measured quantitatively in cultured cells and could be noninvasively visualized in living animals using a gamma camera. The results of this study could open up a new approach for measuring the in vivo delivery of small RNAs that might further facilitate the development of siRNAs as targeted therapies

  6. Development of an Extracorporeal Perfusion Device for Small Animal Free Flaps.

    Directory of Open Access Journals (Sweden)

    Andreas M Fichter

    Full Text Available Extracorporeal perfusion (ECP might prolong the vital storage capabilities of composite free flaps, potentially opening a wide range of clinical applications. Aim of the study was the development a validated low-cost extracorporeal perfusion model for further research in small animal free flaps.After establishing optimal perfusion settings, a specially designed extracorporeal perfusion system was evaluated during 8-hour perfusion of rat epigastric flaps followed by microvascular free flap transfer. Controls comprised sham-operation, ischemia and in vivo perfusion. Flaps and perfusate (diluted blood were closely monitored by blood gas analysis, combined laser Doppler flowmetry and remission spectroscopy and Indocyanine-Green angiography. Evaluations were complemented by assessment of necrotic area and light microscopy at day 7.ECP was established and maintained for 8 hours with constant potassium and pH levels. Subsequent flap transfer was successful. Notably, the rate of necrosis of extracorporeally perfused flaps (27% was even lower than after in vivo perfusion (49%, although not statistically significant (P = 0,083. After sham-operation, only 6% of the total flap area became necrotic, while 8-hour ischemia led to total flap loss (98%. Angiographic and histological findings confirmed these observations.Vital storage capabilities of microvascular flaps can be prolonged by temporary ECP. Our study provides important insights on the pathophysiological processes during extracorporeal tissue perfusion and provides a validated small animal perfusion model for further studies.

  7. A new generation of PET scanners for small animal studies

    International Nuclear Information System (INIS)

    Hegyesi, G.; Imrek, J.; Kalinka, G.; Molnar, J.; Novak, D.; Valastyan, I.; Balkay, L.; Emri, M.; Kis, S.; Tron, L.

    2008-01-01

    Complete text of publication follows. Research on small animal PET scanners has been a hot topic in recent years. These devices are used in the preclinical phases of drug tests and during the development of new radiopharmaceuticals. They also provide a cost efficient way to test new materials, new design concepts and new technologies that later can be used to build more efficient human medical imaging devices. The development of a PET scanner requires expertise on different fields, therefore a consortium was formed that brought together Hungarian academic and industrial partners: the Nuclear Research Institute (which has experience in the development of nuclear detectors and data acquisition systems), the PET Center of the University of Debrecen (which has clinical experience in the application of nuclear imaging devices and background in image processing software), Mediso Ltd. (which has been developing, manufacturing, selling and servicing medical imaging devices since 1990) and other academic partners. This consortium has been working together since 2003: the knowledge base acquired during the development of our small animal PET scanners (miniPET-I and miniPET-II) is now being utilized to build a commercial multimodal human PET scanner. The operation of a PET scanner is based on the simultaneous detection ('coincidence') of two gamma photons originating from a positron annihilation. In traditional PET scanners coincidence is detected by a central unit during the measurement. In our system there is no such central module: all detected single gamma events are recorded (list mode data acquisition), and the list of events are processed using a computer cluster (built from PCs). The usage of independent detector modules and commercial components reduce both development and maintenance costs. Also, this mode of data acquisition is more suitable for development purposes, since once the data is collected and stored it can be used many times to test different signal

  8. 3D absorbed dose calculation with GATE Monte Carlo simulation for the image-guided radiation therapy dedicated to the small animal

    International Nuclear Information System (INIS)

    Noblet, Caroline

    2014-01-01

    Innovating irradiators dedicated to small animal allow to mimic clinical treatments in image-guided radiation therapy. Clinical practice is scaled down to the small animal by reducing beam dimensions (from cm to mm) and energy (from MeV to keV). Millimeter medium energy beams ( [fr

  9. Automated Computational Processing of 3-D MR Images of Mouse Brain for Phenotyping of Living Animals.

    Science.gov (United States)

    Medina, Christopher S; Manifold-Wheeler, Brett; Gonzales, Aaron; Bearer, Elaine L

    2017-07-05

    Magnetic resonance (MR) imaging provides a method to obtain anatomical information from the brain in vivo that is not typically available by optical imaging because of this organ's opacity. MR is nondestructive and obtains deep tissue contrast with 100-µm 3 voxel resolution or better. Manganese-enhanced MRI (MEMRI) may be used to observe axonal transport and localized neural activity in the living rodent and avian brain. Such enhancement enables researchers to investigate differences in functional circuitry or neuronal activity in images of brains of different animals. Moreover, once MR images of a number of animals are aligned into a single matrix, statistical analysis can be done comparing MR intensities between different multi-animal cohorts comprising individuals from different mouse strains or different transgenic animals, or at different time points after an experimental manipulation. Although preprocessing steps for such comparisons (including skull stripping and alignment) are automated for human imaging, no such automated processing has previously been readily available for mouse or other widely used experimental animals, and most investigators use in-house custom processing. This protocol describes a stepwise method to perform such preprocessing for mouse. © 2017 by John Wiley & Sons, Inc. Copyright © 2017 John Wiley & Sons, Inc.

  10. RFID Technology for Continuous Monitoring of Physiological Signals in Small Animals.

    Science.gov (United States)

    Volk, Tobias; Gorbey, Stefan; Bhattacharyya, Mayukh; Gruenwald, Waldemar; Lemmer, Björn; Reindl, Leonhard M; Stieglitz, Thomas; Jansen, Dirk

    2015-02-01

    Telemetry systems enable researchers to continuously monitor physiological signals in unrestrained, freely moving small rodents. Drawbacks of common systems are limited operation time, the need to house the animals separately, and the necessity of a stable communication link. Furthermore, the costs of the typically proprietary telemetry systems reduce the acceptance. The aim of this paper is to introduce a low-cost telemetry system based on common radio frequency identification technology optimized for battery-independent operational time, good reusability, and flexibility. The presented implant is equipped with sensors to measure electrocardiogram, arterial blood pressure, and body temperature. The biological signals are transmitted as digital data streams. The device is able of monitoring several freely moving animals housed in groups with a single reader station. The modular concept of the system significantly reduces the costs to monitor multiple physiological functions and refining procedures in preclinical research.

  11. Potential Applications of Flat-Panel Volumetric CT in Morphologic, Functional Small Animal Imaging

    Directory of Open Access Journals (Sweden)

    Susanne Greschus

    2005-08-01

    Full Text Available Noninvasive radiologic imaging has recently gained considerable interest in basic, preclinical research for monitoring disease progression, therapeutic efficacy. In this report, we introduce flat-panel volumetric computed tomography (fpVCT as a powerful new tool for noninvasive imaging of different organ systems in preclinical research. The three-dimensional visualization that is achieved by isotropic high-resolution datasets is illustrated for the skeleton, chest, abdominal organs, brain of mice. The high image quality of chest scans enables the visualization of small lung nodules in an orthotopic lung cancer model, the reliable imaging of therapy side effects such as lung fibrosis. Using contrast-enhanced scans, fpVCT displayed the vascular trees of the brain, liver, kidney down to the subsegmental level. Functional application of fpVCT in dynamic contrast-enhanced scans of the rat brain delivered physiologically reliable data of perfusion, tissue blood volume. Beyond scanning of small animal models as demonstrated here, fpVCT provides the ability to image animals up to the size of primates.

  12. Utility of Small Animal Models of Developmental Programming.

    Science.gov (United States)

    Reynolds, Clare M; Vickers, Mark H

    2018-01-01

    Any effective strategy to tackle the global obesity and rising noncommunicable disease epidemic requires an in-depth understanding of the mechanisms that underlie these conditions that manifest as a consequence of complex gene-environment interactions. In this context, it is now well established that alterations in the early life environment, including suboptimal nutrition, can result in an increased risk for a range of metabolic, cardiovascular, and behavioral disorders in later life, a process preferentially termed developmental programming. To date, most of the mechanistic knowledge around the processes underpinning development programming has been derived from preclinical research performed mostly, but not exclusively, in laboratory mouse and rat strains. This review will cover the utility of small animal models in developmental programming, the limitations of such models, and potential future directions that are required to fully maximize information derived from preclinical models in order to effectively translate to clinical use.

  13. Design of small-animal thermal neutron irradiation facility at the Brookhaven Medical Research Reactor

    International Nuclear Information System (INIS)

    Liu, H.B.

    1996-01-01

    The broad beam facility (BBF) at the Brookhaven Medical Research Reactor (BMRR) can provide a thermal neutron beam with flux intensity and quality comparable to the beam currently used for research on neutron capture therapy using cell-culture and small-animal irradiations. Monte Carlo computations were made, first, to compare with the dosimetric measurements at the existing BBF and, second, to calculate the neutron and gamma fluxes and doses expected at the proposed BBF. Multiple cell cultures or small animals could be irradiated simultaneously at the so-modified BBF under conditions similar to or better than those individual animals irradiated at the existing thermal neutron irradiation Facility (TNIF) of the BMRR. The flux intensity of the collimated thermal neutron beam at the proposed BBF would be 1.7 x 10 10 n/cm 2 ·s at 3-MW reactor power, the same as at the TNIF. However, the proposed collimated beam would have much lower gamma (0.89 x 10 -11 cGy·cm 2 /n th ) and fast neutron (0.58 x 10 -11 cGy·cm 2 /n th ) contaminations, 64 and 19% of those at the TNIF, respectively. The feasibility of remodeling the facility is discussed

  14. Weighing Animal Lives : A Critical Assessment of Justification and Prioritization in Animal-Rights Theories

    OpenAIRE

    Karlsson, Fredrik

    2009-01-01

    The project underlying this dissertation aims at analyzing three pro-animal-rights theories, evaluating the theories, and outlining an alternative theoretical account of animal rights. The analytical categories are justification and function of animal rights, the definition of the right holder, and the resolution approach to rights conflict. The categories are applied to a naturalist, a theocentric, and a contractarian approach to defend animal rights. The evaluation is substantiated by the a...

  15. Real-time phase-contrast x-ray imaging: a new technique for the study of animal form and function

    International Nuclear Information System (INIS)

    Socha, J.; Lee, W.; Chicago Field Museum; Arizona State Univ.

    2007-01-01

    Despite advances in imaging techniques, real-time visualization of the structure and dynamics of tissues and organs inside small living animals has remained elusive. Recently, we have been using synchrotron x-rays to visualize the internal anatomy of millimeter-sized opaque, living animals. This technique takes advantage of partially-coherent x-rays and diffraction to enable clear visualization of internal soft tissue not viewable via conventional absorption radiography. However, because higher quality images require greater x-ray fluxes, there exists an inherent tradeoff between image quality and tissue damage

  16. Effect of very high pressure on life of plants and animals

    International Nuclear Information System (INIS)

    Ono, F; Mori, Y; Sougawa, M; Takarabe, K; Hada, Y; Nishihira, N; Motose, H; Saigusa, M; Matsushima, Y; Yamazaki, D; Ito, E; Saini, N L

    2012-01-01

    We studied the tolerance of living organisms, such as a small animal (Milnesium tardigradum), a small crustacean (Artemia), non-vascular plants or moss (Ptichomitrium and Venturiella), and a vascular plant (Trifolium) to the extremely high hydrostatic pressure of 7.5 GPa. It turned out that most of the high pressure exposed seeds of white clover were alive. Those exposed to 7.5 GPa for up to 1 day and seeded on agar germinated roots. Those exposed for up to 1 hour and seeded on soil germinated stems and leaves. Considering the fact that proteins begins to unfold around 0.3 GPa, it seems difficult to understand that all the living samples which have been investigated can survive after exposure to 7.5 GPa.

  17. Small-animal whole-body imaging using a photoacoustic full ring array system

    Science.gov (United States)

    Xia, Jun; Guo, Zijian; Aguirre, Andres; Zhu, Quing; Wang, Lihong V.

    2011-03-01

    In this report, we present a novel 3D photoacoustic computed tomography (PACT) system for small-animal whole-body imaging. The PACT system, based on a 512-element full-ring transducer array, received photoacoustic signals primarily from a 2-mm-thick slice. The light was generated by a pulse laser, and can either illuminate from the top or be reshaped to illuminate the sample from the side, using a conical lens and an optical condenser. The PACT system was capable of acquiring an in-plane image in 1.6 s; by scanning the sample in the elevational direction, a 3D tomographic image could be constructed. We tested the system by imaging a cylindrical phantom made of human hairs immersed in a scattering medium. The reconstructed image achieved an in-plane resolution of 0.1 mm and an elevational resolution of 1 mm. After deconvolution in the elevational direction, the 3D image was found to match well with the phantom. The system was also used to image a baby mouse in situ; the spinal cord and ribs can be seen easily in the reconstructed image. Our results demonstrate that the PACT system has the potential to be used for fast small-animal whole-body tomographic imaging.

  18. Establishment study of the in vivo imaging analysis with small animal imaging modalities for bio-durg development

    International Nuclear Information System (INIS)

    Jang, Beomsu; Park, Sanghyeon; Choi, Dae Seong; Park, Jeonghoon; Jung, Uhee; Lee, Yun Jong

    2012-01-01

    In this study, we established the image modalities (micro-PET, SPECT/CT) using the experimental animal (mouse) for the development of imaging assessment method for the bio-durg and extramural collaboration proposal. We examined the micro-SPECT/CT, PET imaging study using the Siemens Inveon micro-multimodality system (SPECT/CT) and imaging study using the Siemens Inveon micro-multimodality system (SPECT/CT) and micro-PET with 99m Tc tricarbonyl bifunctional chelators and 18 F-clotrimazole derivative. SPECT imaging studies were performed with 99m Tc tricarbonyl BFCs. PET imaging study was performed with 18 F-clotrimazole derivatives. We performed the PET image study of 18 F-clotrimazole derivatives using U87MG tumor bearing mice. Also we tested the intramural and extramural collaboration using small animal imaging modalities and prepared the draft of extramural R and D operation manual for small animal imaging modalities and the experimental animal imaging facility. These research results can be utilized as a basic image study protocols and data for the image assessment of drugs including biological drug

  19. A Modified Carbon Monoxide Breath Test for Measuring Erythrocyte Lifespan in Small Animals

    Directory of Open Access Journals (Sweden)

    Yong-Jian Ma

    2016-01-01

    Full Text Available This study was to develop a CO breath test for RBC lifespan estimation of small animals. The ribavirin induced hemolysis rabbit models were placed individually in a closed rebreath cage and air samples were collected for measurement of CO concentration. RBC lifespan was calculated from accumulated CO, blood volume, and hemoglobin concentration data. RBC lifespan was determined in the same animals with the standard biotin-labeling method. RBC lifespan data obtained by the CO breath test method for control (CON, 49.0±5.9 d rabbits, rabbits given 10 mg/kg·d−1 of ribavirin (RIB10, 31.0±4.0 d, and rabbits given 20 mg/kg·d−1 of ribavirin (RIB20, 25.0±2.9 d were statistically similar (all p>0.05 to and linearly correlated (r=0.96, p<0.01 with the RBC lifespan data obtained for the same rabbits by the standard biotin-labeling method (CON, 51.0±2.7 d; RIB10, 33.0±1.3 d; and RIB20, 27.0±0.8 d. The CO breath test method takes less than 3 h to complete, whereas the standard method requires at least several weeks. In conclusion, the CO breath test method provides a simple and rapid means of estimating RBC lifespan and is feasible for use with small animal models.

  20. GATE simulation of a new design of pinhole SPECT system for small animal brain imaging

    International Nuclear Information System (INIS)

    Ozsahin, D. Uzun; Bläckberg, L.; Fakhri, G. El; Sabet, H.

    2017-01-01

    Small animal SPECT imaging has gained an increased interest over the past decade since it is an excellent tool for developing new drugs and tracers. Therefore, there is a huge effort on the development of cost-effective SPECT detectors with high capabilities. The aim of this study is to simulate the performance characteristics of new designs for a cost effective, stationary SPECT system dedicated to small animal imaging with a focus on mice brain. The conceptual design of this SPECT system platform, Stationary Small Animal SSA-SPECT, is to use many pixelated CsI:TI detector modules with 0.4 mm × 0.4 mm pixels in order to achieve excellent intrinsic detector resolution where each module is backed by a single pinhole collimator with 0.3 mm hole diameter. In this work, we present the simulation results of four variations of the SSA-SPECT platform where the number of detector modules and FOV size is varied while keeping the detector size and collimator hole size constant. Using the NEMA NU-4 protocol, we performed spatial resolution, sensitivity, image quality simulations followed by a Derenzo-like phantom evaluation. The results suggest that all four SSA-SPECT systems can provide better than 0.063% system sensitivity and < 1.5 mm FWHM spatial resolution without resolution recovery or other correction techniques. Specifically, SSA-SPECT-1 showed a system sensitivity of 0.09% in combination with 1.1 mm FWHM spatial resolution.

  1. Development an Automatic Speech to Facial Animation Conversion for Improve Deaf Lives

    Directory of Open Access Journals (Sweden)

    S. Hamidreza Kasaei

    2011-05-01

    Full Text Available In this paper, we propose design and initial implementation of a robust system which can automatically translates voice into text and text to sign language animations. Sign Language
    Translation Systems could significantly improve deaf lives especially in communications, exchange of information and employment of machine for translation conversations from one language to another has. Therefore, considering these points, it seems necessary to study the speech recognition. Usually, the voice recognition algorithms address three major challenges. The first is extracting feature form speech and the second is when limited sound gallery are available for recognition, and the final challenge is to improve speaker dependent to speaker independent voice recognition. Extracting feature form speech is an important stage in our method. Different procedures are available for extracting feature form speech. One of the commonest of which used in speech
    recognition systems is Mel-Frequency Cepstral Coefficients (MFCCs. The algorithm starts with preprocessing and signal conditioning. Next extracting feature form speech using Cepstral coefficients will be done. Then the result of this process sends to segmentation part. Finally recognition part recognizes the words and then converting word recognized to facial animation. The project is still in progress and some new interesting methods are described in the current report.

  2. Role of surgery in multimodal cancer therapy for small animals.

    Science.gov (United States)

    Boston, Sarah; Henderson, Ralph A

    2014-09-01

    Surgery is a critical component in the treatment of most solid tumors in small animals. Surgery is increasingly combined with adjuvant therapies such as chemotherapy and radiation so surgeons who are treating cancer must have a good understanding of surgical oncology principles, cancer biology, and the roles and potential interactions of surgery, radiation, and chemotherapy. The sequencing plan for these modalities should be determined before treatment is initiated. The surgical oncologist must have a working knowledge of chemotherapy agents and radiation and the effect of these treatments on the ability of tissues to heal and the outcome for the patient. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. TH-EF-207A-05: Feasibility of Applying SMEIR Method On Small Animal 4D Cone Beam CT Imaging

    International Nuclear Information System (INIS)

    Zhong, Y; Zhang, Y; Shao, Y; Wang, J

    2016-01-01

    Purpose: Small animal cone beam CT imaging has been widely used in preclinical research. Due to the higher respiratory rate and heat beats of small animals, motion blurring is inevitable and needs to be corrected in the reconstruction. Simultaneous motion estimation and image reconstruction (SMEIR) method, which uses projection images of all phases, proved to be effective in motion model estimation and able to reconstruct motion-compensated images. We demonstrate the application of SMEIR for small animal 4D cone beam CT imaging by computer simulations on a digital rat model. Methods: The small animal CBCT imaging system was simulated with the source-to-detector distance of 300 mm and the source-to-object distance of 200 mm. A sequence of rat phantom were generated with 0.4 mm 3 voxel size. The respiratory cycle was taken as 1.0 second and the motions were simulated with a diaphragm motion of 2.4mm and an anterior-posterior expansion of 1.6 mm. The projection images were calculated using a ray-tracing method, and 4D-CBCT were reconstructed using SMEIR and FDK methods. The SMEIR method iterates over two alternating steps: 1) motion-compensated iterative image reconstruction by using projections from all respiration phases and 2) motion model estimation from projections directly through a 2D-3D deformable registration of the image obtained in the first step to projection images of other phases. Results: The images reconstructed using SMEIR method reproduced the features in the original phantom. Projections from the same phase were also reconstructed using FDK method. Compared with the FDK results, the images from SMEIR method substantially improve the image quality with minimum artifacts. Conclusion: We demonstrate that it is viable to apply SMEIR method to reconstruct small animal 4D-CBCT images.

  4. Anaphylaxis Imaging: Non-Invasive Measurement of Surface Body Temperature and Physical Activity in Small Animals.

    Directory of Open Access Journals (Sweden)

    Krisztina Manzano-Szalai

    Full Text Available In highly sensitized patients, the encounter with a specific allergen from food, insect stings or medications may rapidly induce systemic anaphylaxis with potentially lethal symptoms. Countless animal models of anaphylaxis, most often in BALB/c mice, were established to understand the pathophysiology and to prove the safety of different treatments. The most common symptoms during anaphylactic shock are drop of body temperature and reduced physical activity. To refine, improve and objectify the currently applied manual monitoring methods, we developed an imaging method for the automated, non-invasive measurement of the whole-body surface temperature and, at the same time, of the horizontal and vertical movement activity of small animals. We tested the anaphylaxis imaging in three in vivo allergy mouse models for i milk allergy, ii peanut allergy and iii egg allergy. These proof-of-principle experiments suggest that the imaging technology represents a reliable non-invasive method for the objective monitoring of small animals during anaphylaxis over time. We propose that the method will be useful for monitoring diseases associated with both, changes in body temperature and in physical behaviour.

  5. Design, construction and testing of a DC bioeffects test enclosure for small animals. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Frazier, M J; Preache, M M

    1980-11-01

    This final report describes both the engineering development of a DC bioeffects test enclosure for small laboratory animals, and the biological protocol for the use of such enclosures in the testing of animals to determine possible biological effects of the environment associated with HVDC transmission lines. The test enclosure which has been designed is a modular unit, which will house up to eight rat-sized animals in individual compartments. Multiple test enclosures can be used to test larger numbers of animals. A prototype test enclosure has been fabricated and tested to characterize its electrical performance characteristics. The test enclosure provides a simulation of the dominant environment associated with HVDC transmission lines; namely, a static electric field and an ion current density. A biological experimental design has been developed for assessing the effects of the dominant components of the HVDC transmission line environment.

  6. SU-E-T-217: Intrinsic Respiratory Gating in Small Animal CT

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Y; Smith, M; Mistry, N [University of Maryland School of Medicine, Baltimore, MD (United States)

    2014-06-01

    Purpose: Preclinical animal models of lung cancer can provide a controlled test-bed for testing dose escalation or function-based-treatment-planning studies. However, to extract lung function, i.e. ventilation, one needs to be able to image the lung at different phases of ventilation (in-hale / ex-hale). Most respiratory-gated imaging using micro-CT involves using an external ventilator and surgical intervention limiting the utility in longitudinal studies. A new intrinsic respiratory retrospective gating method was developed and tested in mice. Methods: A fixed region of interest (ROI) that covers the diaphragm was selected on all projection images to estimate the mean intensity (M). The mean intensity depends on the projection angle and diaphragm position. A 3-point moving average (A) of consecutive M values: Mpre, Mcurrent and Mpost, was calculated to be subtracted from Mcurrent. A fixed threshold was used to enable amplitude based sorting into 4 different phases of respiration. Images at full-inhale and end-exhale phases of respiration were reconstructed using the open source OSCaR. Lung volumes estimated at the 2 phases of respiration were validated against literature values. Results: Intrinsic retrospective gating was accomplished without the use of any external breathing waveform. While projection images were acquired at 360 different angles. Only 138 and 104 projections were used to reconstruct images at full-inhale and end-exhale. This often results in non-uniform under-sampled angular projections leading to some minor streaking artifacts. The calculated expiratory, inspiratory and tidal lung volumes correlated well with the values known from the literature. Conclusion: Our initial result demonstrates an intrinsic gating method that is suitable for flat panel cone beam small animal CT systems. Reduction in streaking artifacts can be accomplished by oversampling the data or using iterative reconstruction methods. This initial experience will enable

  7. Design of an advanced positron emission tomography detector system and algorithms for imaging small animal models of human disease

    Science.gov (United States)

    Foudray, Angela Marie Klohs

    Detecting, quantifying and visualizing biochemical mechanism in a living system without perturbing function is the goal of the instrument and algorithms designed in this thesis. Biochemical mechanisms of cells have long been known to be dependent on the signals they receive from their environment. Studying biological processes of cells in-vitro can vastly distort their function, since you are removing them from their natural chemical signaling environment. Mice have become the biological system of choice for various areas of biomedical research due to their genetic and physiological similarities with humans, the relatively low cost of their care, and their quick breeding cycle. Drug development and efficacy assessment along with disease detection, management, and mechanism research all have benefited from the use of small animal models of human disease. A high resolution, high sensitivity, three-dimensional (3D) positioning positron emission tomography (PET) detector system was designed through device characterization and Monte Carlo simulation. Position-sensitive avalanche photodiodes (PSAPDs) were characterized in various packaging configurations; coupled to various configurations of lutetium oxyorthosilicate (LSO) scintillation crystals. Forty novelly packaged final design devices were constructed and characterized, each providing characteristics superior to commercially available scintillation detectors used in small animal imaging systems: ˜1mm crystal identification, 14-15% of 511 keV energy resolution, and averaging 1.9 to 5.6 ns coincidence time resolution. A closed-cornered box-shaped detector configuration was found to provide optimal photon sensitivity (˜10.5% in the central plane) using dual LSO-PSAPD scintillation detector modules and Monte Carlo simulation. Standard figures of merit were used to determine optimal system acquisition parameters. A realistic model for constituent devices was developed for understanding the signals reported by the

  8. A training course on laboratory animal science: an initiative to implement the Three Rs of animal research in India.

    Science.gov (United States)

    Pratap, Kunal; Singh, Vijay Pal

    2016-03-01

    There is a current need for a change in the attitudes of researchers toward the care and use of experimental animals in India. This could be achieved through improvements in the provision of training, to further the integration of the Three Rs concept into scientific research and into the regulations of the Committee for the Purpose of Control and Supervision of Experiments on Animals (CPCSEA). A survey was performed after participants undertook the Federation of European Laboratory Animal Science Associations (FELASA) Category C-based course on Laboratory Animal Science (in 2013 and 2015). It revealed that the participants subsequently employed, in their future research, the practical and theoretical Three Rs approaches that they had learned. This is of great importance in terms of animal welfare, and also serves to benefit their research outcomes extensively. All the lectures, hands-on practical sessions and supplementary elements of the courses, which also involved the handling of small animals and procedures with live animals, were well appreciated by the participants. Insight into developments in practical handling and welfare procedures, norms, directives, and ethical use of laboratory animals in research, was also provided, through the comparison of results from the 2013 and 2015 post-course surveys. 2016 FRAME.

  9. In Vivo Respiratory-Gated Micro-CT Imaging in Small-Animal Oncology Models

    Directory of Open Access Journals (Sweden)

    Dawn Cavanaugh

    2004-01-01

    Full Text Available Micro-computed tomography (micro-CT is becoming an accepted research tool for the noninvasive examination of laboratory animals such as mice and rats, but to date, in vivo scanning has largely been limited to the evaluation of skeletal tissues. We use a commercially available micro-CT device to perform respiratory gated in vivo acquisitions suitable for thoracic imaging. The instrument is described, along with the scan protocol and animal preparation techniques. Preliminary results confirm that lung tumors as small as 1 mm in diameter are visible in vivo with these methods. Radiation dose was evaluated using several approaches, and was found to be approximately 0.15 Gy for this respiratory-gated micro-CT imaging protocol. The combination of high-resolution CT imaging and respiratory-gated acquisitions appears well-suited to serial in vivo scanning.

  10. Image-guided small animal radiation research platform: calibration of treatment beam alignment

    International Nuclear Information System (INIS)

    Matinfar, Mohammad; Iordachita, Iulian; Kazanzides, Peter; Ford, Eric; Wong, John

    2009-01-01

    Small animal research allows detailed study of biological processes, disease progression and response to therapy with the potential to provide a natural bridge to the clinical environment. The small animal radiation research platform (SARRP) is a portable system for precision irradiation with beam sizes down to approximately 0.5 mm and optimally planned radiation with on-board cone-beam CT (CBCT) guidance. This paper focuses on the geometric calibration of the system for high-precision irradiation. A novel technique for the calibration of the treatment beam is presented, which employs an x-ray camera whose precise positioning need not be known. Using the camera system we acquired a digitally reconstructed 3D 'star shot' for gantry calibration and then developed a technique to align each beam to a common isocenter with the robotic animal positioning stages. The calibration incorporates localization by cone-beam CT guidance. Uncorrected offsets of the beams with respect to the calibration origin ranged from 0.4 mm to 5.2 mm. With corrections, these alignment errors can be reduced to the sub-millimeter range. The calibration technique was used to deliver a stereotactic-like arc treatment to a phantom constructed with EBT Gafchromic films. All beams were shown to intersect at a common isocenter with a measured beam (FWHM) of approximately 1.07 mm using the 0.5 mm collimated beam. The desired positioning accuracy of the SARRP is 0.25 mm and the results indicate an accuracy of 0.2 mm. To fully realize the radiation localization capabilities of the SARRP, precise geometric calibration is required, as with any such system. The x-ray camera-based technique presented here provides a straightforward and semi-automatic method for system calibration.

  11. Assessment of the sources of error affecting the quantitative accuracy of SPECT imaging in small animals

    Energy Technology Data Exchange (ETDEWEB)

    Joint Graduate Group in Bioengineering, University of California, San Francisco and University of California, Berkeley; Department of Radiology, University of California; Gullberg, Grant T; Hwang, Andrew B.; Franc, Benjamin L.; Gullberg, Grant T.; Hasegawa, Bruce H.

    2008-02-15

    Small animal SPECT imaging systems have multiple potential applications in biomedical research. Whereas SPECT data are commonly interpreted qualitatively in a clinical setting, the ability to accurately quantify measurements will increase the utility of the SPECT data for laboratory measurements involving small animals. In this work, we assess the effect of photon attenuation, scatter and partial volume errors on the quantitative accuracy of small animal SPECT measurements, first with Monte Carlo simulation and then confirmed with experimental measurements. The simulations modeled the imaging geometry of a commercially available small animal SPECT system. We simulated the imaging of a radioactive source within a cylinder of water, and reconstructed the projection data using iterative reconstruction algorithms. The size of the source and the size of the surrounding cylinder were varied to evaluate the effects of photon attenuation and scatter on quantitative accuracy. We found that photon attenuation can reduce the measured concentration of radioactivity in a volume of interest in the center of a rat-sized cylinder of water by up to 50percent when imaging with iodine-125, and up to 25percent when imaging with technetium-99m. When imaging with iodine-125, the scatter-to-primary ratio can reach up to approximately 30percent, and can cause overestimation of the radioactivity concentration when reconstructing data with attenuation correction. We varied the size of the source to evaluate partial volume errors, which we found to be a strong function of the size of the volume of interest and the spatial resolution. These errors can result in large (>50percent) changes in the measured amount of radioactivity. The simulation results were compared with and found to agree with experimental measurements. The inclusion of attenuation correction in the reconstruction algorithm improved quantitative accuracy. We also found that an improvement of the spatial resolution through the

  12. High resolution propagation-based imaging system for in vivo dynamic computed tomography of lungs in small animals

    Science.gov (United States)

    Preissner, M.; Murrie, R. P.; Pinar, I.; Werdiger, F.; Carnibella, R. P.; Zosky, G. R.; Fouras, A.; Dubsky, S.

    2018-04-01

    We have developed an x-ray imaging system for in vivo four-dimensional computed tomography (4DCT) of small animals for pre-clinical lung investigations. Our customized laboratory facility is capable of high resolution in vivo imaging at high frame rates. Characterization using phantoms demonstrate a spatial resolution of slightly below 50 μm at imaging rates of 30 Hz, and the ability to quantify material density differences of at least 3%. We benchmark our system against existing small animal pre-clinical CT scanners using a quality factor that combines spatial resolution, image noise, dose and scan time. In vivo 4DCT images obtained on our system demonstrate resolution of important features such as blood vessels and small airways, of which the smallest discernible were measured as 55–60 μm in cross section. Quantitative analysis of the images demonstrate regional differences in ventilation between injured and healthy lungs.

  13. Programmable electronics for low-cost small animal PET/SPECT imaging

    International Nuclear Information System (INIS)

    Guerra, Pedro; Rubio, Jose L.; Kontaxakis, Georgios; Ortuno, Juan E.; Ledesma, Maria J.; Santos, Andres

    2006-01-01

    This work describes and characterizes the detector module of a novel positron/single photon emission (PET/SPECT) scanner for small animals. This detector consists of a YAP/LSO phoswich, a photomultiplier and acquisition front-end, and will be used as building block of a low-cost hybrid tomograph. The front-end processes data sampled at a fixed frequency, where a state-of-the-art programmable device estimates scintillation pulse parameters by means of digital algorithms. Finally, the estimated properties of the proposed detector module are used to model a rotating four-head scanner. The performance of the proposed PET/SPECT scanner is estimated and first results are promising in both modalities, deserving further research and optimization

  14. Micro-computed tomography newly developed for in vivo small animal imaging

    International Nuclear Information System (INIS)

    Arai, Yoshinori; Ninomiya, Tadashi; Kato, Takafumi; Masuda, Yuji

    2005-01-01

    The aim of this paper is to report a newly developed micro-computed tomography system for in vivo use. The system was composed of a micro-focus X-ray tube and an image intensifier (I.I.), both of which rotated around the object stage. A guinea pig and a rat were examined. The anesthetized animal was set on the secure object stage. Images of the head of the guinea pig and the tibia knee joint of the rat were taken. In addition, an image of the rat's tail was taken. The reconstruction and the image viewing were carried out using I-View software. The voxel matrix was 512 x 512 x 384. The voxel sizes ranged from 10 x 10 x 10 μm to 100 x 100 x 100 μm. The exposure time was 17 s, and the reconstruction time was 150 s. The head of the guinea pig and the tibia/knee joint of the rat were observed clearly under 100-μm and 30μm voxels, respectively. The trabecular bone of the tail was also observed clearly under a 10 μm voxel. The newly developed micro-computed tomography system makes it possible to obtain images of anesthetized animals set on a secure object stage. Clear bone images of the small animals could be obtained within a short time. (author)

  15. Evaluation of Matrix9 silicon photomultiplier array for small-animal PET

    Science.gov (United States)

    Du, Junwei; Schmall, Jeffrey P.; Yang, Yongfeng; Di, Kun; Roncali, Emilie; Mitchell, Gregory S.; Buckley, Steve; Jackson, Carl; Cherry, Simon R.

    2015-01-01

    Purpose: The MatrixSL-9-30035-OEM (Matrix9) from SensL is a large-area silicon photomultiplier (SiPM) photodetector module consisting of a 3 × 3 array of 4 × 4 element SiPM arrays (total of 144 SiPM pixels) and incorporates SensL’s front-end electronics board and coincidence board. Each SiPM pixel measures 3.16 × 3.16 mm2 and the total size of the detector head is 47.8 × 46.3 mm2. Using 8 × 8 polished LSO/LYSO arrays (pitch 1.5 mm) the performance of this detector system (SiPM array and readout electronics) was evaluated with a view for its eventual use in small-animal positron emission tomography (PET). Methods: Measurements of noise, signal, signal-to-noise ratio, energy resolution, flood histogram quality, timing resolution, and array trigger error were obtained at different bias voltages (28.0–32.5 V in 0.5 V intervals) and at different temperatures (5 °C–25 °C in 5 °C degree steps) to find the optimal operating conditions. Results: The best measured signal-to-noise ratio and flood histogram quality for 511 keV gamma photons were obtained at a bias voltage of 30.0 V and a temperature of 5 °C. The energy resolution and timing resolution under these conditions were 14.2% ± 0.1% and 4.2 ± 0.1 ns, respectively. The flood histograms show that all the crystals in the 1.5 mm pitch LSO array can be clearly identified and that smaller crystal pitches can also be resolved. Flood histogram quality was also calculated using different center of gravity based positioning algorithms. Improved and more robust results were achieved using the local 9 pixels for positioning along with an energy offset calibration. To evaluate the front-end detector readout, and multiplexing efficiency, an array trigger error metric is introduced and measured at different lower energy thresholds. Using a lower energy threshold greater than 150 keV effectively eliminates any mispositioning between SiPM arrays. Conclusions: In summary, the Matrix9 detector system can resolve

  16. Evaluation of Matrix9 silicon photomultiplier array for small-animal PET

    International Nuclear Information System (INIS)

    Du, Junwei; Schmall, Jeffrey P.; Yang, Yongfeng; Di, Kun; Roncali, Emilie; Mitchell, Gregory S.; Buckley, Steve; Jackson, Carl; Cherry, Simon R.

    2015-01-01

    Purpose: The MatrixSL-9-30035-OEM (Matrix9) from SensL is a large-area silicon photomultiplier (SiPM) photodetector module consisting of a 3 × 3 array of 4 × 4 element SiPM arrays (total of 144 SiPM pixels) and incorporates SensL’s front-end electronics board and coincidence board. Each SiPM pixel measures 3.16 × 3.16 mm 2 and the total size of the detector head is 47.8 × 46.3 mm 2 . Using 8 × 8 polished LSO/LYSO arrays (pitch 1.5 mm) the performance of this detector system (SiPM array and readout electronics) was evaluated with a view for its eventual use in small-animal positron emission tomography (PET). Methods: Measurements of noise, signal, signal-to-noise ratio, energy resolution, flood histogram quality, timing resolution, and array trigger error were obtained at different bias voltages (28.0–32.5 V in 0.5 V intervals) and at different temperatures (5 °C–25 °C in 5 °C degree steps) to find the optimal operating conditions. Results: The best measured signal-to-noise ratio and flood histogram quality for 511 keV gamma photons were obtained at a bias voltage of 30.0 V and a temperature of 5 °C. The energy resolution and timing resolution under these conditions were 14.2% ± 0.1% and 4.2 ± 0.1 ns, respectively. The flood histograms show that all the crystals in the 1.5 mm pitch LSO array can be clearly identified and that smaller crystal pitches can also be resolved. Flood histogram quality was also calculated using different center of gravity based positioning algorithms. Improved and more robust results were achieved using the local 9 pixels for positioning along with an energy offset calibration. To evaluate the front-end detector readout, and multiplexing efficiency, an array trigger error metric is introduced and measured at different lower energy thresholds. Using a lower energy threshold greater than 150 keV effectively eliminates any mispositioning between SiPM arrays. Conclusions: In summary, the Matrix9 detector system can

  17. Animal Detectives

    Science.gov (United States)

    Mulvey, Bridget; Warnock, Carly

    2015-01-01

    During a two-week inquiry-based 5E learning cycle unit, children made observations and inferences to guide their explorations of animal traits and habitats (Bybee 2014). The children became "animal detectives" by studying a live-feed webcam and digital images of wolves in their natural habitat, reading books and online sources about…

  18. Biological effects of high-strength electric fields on small laboratory animals. Interim report, March 1, 1978-September 30, 1979

    Energy Technology Data Exchange (ETDEWEB)

    Phillips, R.D.; Anderson, L.E.; Kaune, W.T.

    1979-12-01

    Progress is described on a project assessing the biological effects of 60-Hz electric fields on small laboratory animals (rats and mice). The report includes sections on hematology and seram chemistry, immunology, pathology, metabolism, bone growth, endocrinology, cardiovascular function, neurophysiology, growth and development, and animal behavior. (ACR)

  19. Determination of tolerance dose uncertainties and optimal design of dose response experiments with small animal numbers

    International Nuclear Information System (INIS)

    Karger, C.P.; Hartmann, G.H.

    2001-01-01

    Background: Dose response experiments aim to determine the complication probability as a function of dose. Adjusting the parameters of the frequently used dose response model P(D)=1/[1+(D 50 /D) k ] to the experimental data, 2 intuitive quantities are obtained: The tolerance dose D 50 and the slope parameter k. For mathematical reasons, however, standard statistic software uses a different set of parameters. Therefore, the resulting fit parameters of the statistic software as well as their standard errors have to be transformed to obtain D 50 and k as well as their standard errors. Material and Methods: The influence of the number of dose levels on the uncertainty of the fit parameters is studied by a simulation for a fixed number of animals. For experiments with small animal numbers, statistical artifacts may prevent the determination of the standard errors of the fit parameters. Consequences on the design of dose response experiments are investigated. Results: Explicit formulas are presented, which allow to calculate the parameters D 50 and k as well as their standard errors from the output of standard statistic software. The simulation shows, that the standard errors of the resulting parameters are independent of the number of dose levels, as long as the total number of animals involved in the experiment, remains constant. Conclusion: Statistical artifacts in experiments containing small animal numbers may be prevented by an adequate design of the experiment. For this, it is suggested to select a higher number of dose levels, rather than using a higher number of animals per dose level. (orig.) [de

  20. Real-time phase-contrast x-ray imaging: a new technique for the study of animal form and function

    Directory of Open Access Journals (Sweden)

    Waters James S

    2007-03-01

    Full Text Available Abstract Background Despite advances in imaging techniques, real-time visualization of the structure and dynamics of tissues and organs inside small living animals has remained elusive. Recently, we have been using synchrotron x-rays to visualize the internal anatomy of millimeter-sized opaque, living animals. This technique takes advantage of partially-coherent x-rays and diffraction to enable clear visualization of internal soft tissue not viewable via conventional absorption radiography. However, because higher quality images require greater x-ray fluxes, there exists an inherent tradeoff between image quality and tissue damage. Results We evaluated the tradeoff between image quality and harm to the animal by determining the impact of targeted synchrotron x-rays on insect physiology, behavior and survival. Using 25 keV x-rays at a flux density of 80 μW/mm-2, high quality video-rate images can be obtained without major detrimental effects on the insects for multiple minutes, a duration sufficient for many physiological studies. At this setting, insects do not heat up. Additionally, we demonstrate the range of uses of synchrotron phase-contrast imaging by showing high-resolution images of internal anatomy and observations of labeled food movement during ingestion and digestion. Conclusion Synchrotron x-ray phase contrast imaging has the potential to revolutionize the study of physiology and internal biomechanics in small animals. This is the only generally applicable technique that has the necessary spatial and temporal resolutions, penetrating power, and sensitivity to soft tissue that is required to visualize the internal physiology of living animals on the scale from millimeters to microns.

  1. Hyperspectral and multispectral bioluminescence optical tomography for small animal imaging

    International Nuclear Information System (INIS)

    Chaudhari, Abhijit J; Darvas, Felix; Bading, James R; Moats, Rex A; Conti, Peter S; Smith, Desmond J; Cherry, Simon R; Leahy, Richard M

    2005-01-01

    For bioluminescence imaging studies in small animals, it is important to be able to accurately localize the three-dimensional (3D) distribution of the underlying bioluminescent source. The spectrum of light produced by the source that escapes the subject varies with the depth of the emission source because of the wavelength-dependence of the optical properties of tissue. Consequently, multispectral or hyperspectral data acquisition should help in the 3D localization of deep sources. In this paper, we describe a framework for fully 3D bioluminescence tomographic image acquisition and reconstruction that exploits spectral information. We describe regularized tomographic reconstruction techniques that use semi-infinite slab or FEM-based diffusion approximations of photon transport through turbid media. Singular value decomposition analysis was used for data dimensionality reduction and to illustrate the advantage of using hyperspectral rather than achromatic data. Simulation studies in an atlas-mouse geometry indicated that sub-millimeter resolution may be attainable given accurate knowledge of the optical properties of the animal. A fixed arrangement of mirrors and a single CCD camera were used for simultaneous acquisition of multispectral imaging data over most of the surface of the animal. Phantom studies conducted using this system demonstrated our ability to accurately localize deep point-like sources and show that a resolution of 1.5 to 2.2 mm for depths up to 6 mm can be achieved. We also include an in vivo study of a mouse with a brain tumour expressing firefly luciferase. Co-registration of the reconstructed 3D bioluminescent image with magnetic resonance images indicated good anatomical localization of the tumour

  2. Online virtual isocenter based radiation field targeting for high performance small animal microirradiation

    Science.gov (United States)

    Stewart, James M. P.; Ansell, Steve; Lindsay, Patricia E.; Jaffray, David A.

    2015-12-01

    Advances in precision microirradiators for small animal radiation oncology studies have provided the framework for novel translational radiobiological studies. Such systems target radiation fields at the scale required for small animal investigations, typically through a combination of on-board computed tomography image guidance and fixed, interchangeable collimators. Robust targeting accuracy of these radiation fields remains challenging, particularly at the millimetre scale field sizes achievable by the majority of microirradiators. Consistent and reproducible targeting accuracy is further hindered as collimators are removed and inserted during a typical experimental workflow. This investigation quantified this targeting uncertainty and developed an online method based on a virtual treatment isocenter to actively ensure high performance targeting accuracy for all radiation field sizes. The results indicated that the two-dimensional field placement uncertainty was as high as 1.16 mm at isocenter, with simulations suggesting this error could be reduced to 0.20 mm using the online correction method. End-to-end targeting analysis of a ball bearing target on radiochromic film sections showed an improved targeting accuracy with the three-dimensional vector targeting error across six different collimators reduced from 0.56+/- 0.05 mm (mean  ±  SD) to 0.05+/- 0.05 mm for an isotropic imaging voxel size of 0.1 mm.

  3. Multi-modality image reconstruction for dual-head small-animal PET

    International Nuclear Information System (INIS)

    Huang, Chang-Han; Chou, Cheng-Ying

    2015-01-01

    The hybrid positron emission tomography/computed tomography (PET/CT) or positron emission tomography/magnetic resonance imaging (PET/MRI) has become routine practice in clinics. The applications of multi-modality imaging can also benefit research advances. Consequently, dedicated small-imaging system like dual-head small-animal PET (DHAPET) that possesses the advantages of high detection sensitivity and high resolution can exploit the structural information from CT or MRI. It should be noted that the special detector arrangement in DHAPET leads to severe data truncation, thereby degrading the image quality. We proposed to take advantage of anatomical priors and total variation (TV) minimization methods to reconstruct PET activity distribution form incomplete measurement data. The objective is to solve the penalized least-squares function consisted of data fidelity term, TV norm and medium root priors. In this work, we employed the splitting-based fast iterative shrinkage/thresholding algorithm to split smooth and non-smooth functions in the convex optimization problems. Our simulations studies validated that the images reconstructed by use of the proposed method can outperform those obtained by use of conventional expectation maximization algorithms or that without considering the anatomical prior information. Additionally, the convergence rate is also accelerated.

  4. Development of a simple photon emission computed tomography dedicated to the small animal

    International Nuclear Information System (INIS)

    Bekaert, V.

    2006-11-01

    The development of in vivo small animal imaging becomes essential to study human pathologies. The ImaBio project of Institut Pluridisciplinaire Hubert Curien (IPHC) fits in the process of developing new instruments for biomedical applications with the development of a multimodality imaging platform dedicated to small animal imaging (AMISSA). This thesis presents the study, the design and the development of a Single Photon Emission Computed Tomography (SPECT) which will be integrated to the AMISSA platform. The result of these developments is the possibility to obtain the spatial distribution of an injected molecule into the animal. The SPECT technical solutions are based on the acquired knowledge of the institute allowing the conception of a device with cameras adapted to the gamma detection produced by the radiotracers used in single photon imaging. In order to cover the entire of the transverse field of view, four gamma cameras are arranged in a ring around the volume of interest. Each camera consists of 5 individual modules based on a YAP:Ce crystal array, a multi-anode photomultiplier and a dedicated multichannel electronic device. Finally, 20 detection modules were calibrated to give the same result for an identical energy deposit. The data are acquired then process to extract the positions and the energies deposited by gamma photons in the crystals. This last information is then gathered to build the projections. The 3D reconstructed image from the projections is carried out by the sequence of two algorithms, analytical and iterative OS-EM, both modified to take into account the singular geometry of our detection system. Finally, the obtained image is fused with the anatomical information given by the micro Computed Tomography system. (author)

  5. Development of a Xanthene-Based Red-Emissive Fluorescent Probe for Visualizing H2O2 in Living Cells, Tissues and Animals.

    Science.gov (United States)

    Zhang, Nan; Dong, Baoli; Kong, Xiuqi; Wang, Chao; Song, Wenhui; Lin, Weiying

    2018-04-25

    Hydrogen peroxide (H 2 O 2 ) plays important roles in the regulation of many biological processes, and the abnormal level of H 2 O 2 has close relation with the initiation and progression of many diseases. Herein, we describe a novel red-emissive fluorescence probe (RhoB) for the visualization of H 2 O 2 in living cells, tissues and animals. RhoB was constructed on the basis of a xanthene-based red-emissive dye, and displayed nearly no fluorescence. After the treatment with H 2 O 2 , RhoB can exhibit red fluorescence with the emission wavelength at 638 nm. RhoB exhibited highly sensitive and selective response to H 2 O 2 . Density functional theory (DFT) calculations were conducted to shed light on the optical properties of RhoB, and natural bond orbital (NBO) calculations demonstrate that the boron atom shows the highest positive electricity and further support the response mechanism. RhoB was successfully applied for imaging of exogenous and endogenous H 2 O 2 in living cells, and also can be utilized for visualizing H 2 O 2 in living tissues and animals.

  6. Evaluation of attenuation and scatter correction requirements in small animal PET and SPECT imaging

    Science.gov (United States)

    Konik, Arda Bekir

    Positron emission tomography (PET) and single photon emission tomography (SPECT) are two nuclear emission-imaging modalities that rely on the detection of high-energy photons emitted from radiotracers administered to the subject. The majority of these photons are attenuated (absorbed or scattered) in the body, resulting in count losses or deviations from true detection, which in turn degrades the accuracy of images. In clinical emission tomography, sophisticated correction methods are often required employing additional x-ray CT or radionuclide transmission scans. Having proven their potential in both clinical and research areas, both PET and SPECT are being adapted for small animal imaging. However, despite the growing interest in small animal emission tomography, little scientific information exists about the accuracy of these correction methods on smaller size objects, and what level of correction is required. The purpose of this work is to determine the role of attenuation and scatter corrections as a function of object size through simulations. The simulations were performed using Interactive Data Language (IDL) and a Monte Carlo based package, Geant4 application for emission tomography (GATE). In IDL simulations, PET and SPECT data acquisition were modeled in the presence of attenuation. A mathematical emission and attenuation phantom approximating a thorax slice and slices from real PET/CT data were scaled to 5 different sizes (i.e., human, dog, rabbit, rat and mouse). The simulated emission data collected from these objects were reconstructed. The reconstructed images, with and without attenuation correction, were compared to the ideal (i.e., non-attenuated) reconstruction. Next, using GATE, scatter fraction values (the ratio of the scatter counts to the total counts) of PET and SPECT scanners were measured for various sizes of NEMA (cylindrical phantoms representing small animals and human), MOBY (realistic mouse/rat model) and XCAT (realistic human model

  7. Real-time visualization of macromolecule uptake by epidermal Langerhans cells in living animals.

    Science.gov (United States)

    Frugé, Rachel E; Krout, Colleen; Lu, Ran; Matsushima, Hironori; Takashima, Akira

    2012-03-01

    As a skin-resident member of the dendritic cell family, Langerhans cells (LCs) are generally regarded to function as professional antigen-presenting cells. Here we report a simple method to visualize the endocytotic activity of LCs in living animals. BALB/c mice received subcutaneous injection of FITC-conjugated dextran (DX) probes into the ear skin and were then examined under confocal microscopy. Large numbers of FITC(+) epidermal cells became detectable 12-24 hours after injection as background fluorescence signals began to disappear. Most (>90%) of the FITC(+) epidermal cells expressed Langerin, and >95% of Langerin(+) epidermal cells exhibited significant FITC signals. To assess intracellular localization, Alexa Fluor 546-conjugated DX probes were locally injected into IAβ-enhanced green fluorescent protein (EGFP) knock-in mice and Langerin-EGFP-diphtheria toxin receptor mice--three dimensional rotation images showed close association of most of the internalized DX probes with major histocompatibility complex (MHC) class II molecules, but not with Langerin molecules. These observations support the current view that LCs constantly sample surrounding materials, including harmful and innocuous antigens, at the environmental interface. Our data also validate the potential utility of the newly developed imaging approach to monitor LC function in wild-type animals.

  8. Development of a Compton suppression whole body counting for small animals

    International Nuclear Information System (INIS)

    Martini, Elaine

    1995-01-01

    The basic operation, design and construction of the plastic scintillator detector is described. In order to increase the sensitivity of this detector, two blocks of plastic scintillator have been assembled to act as a anticompton system. The detectors were produced by polymerisation of styrene monomer with PPO (2,5 diphenyl-oxazole) and POPOP (1,4 bis (-5 phenyl-2- oxazoly)benzene) in proportions of 0.5 and 0.05 respectively. The transparency of this detector was evaluated by excitation of the 241 Am source located directly in the back surface plastic coupled to a photomultiplier. The light attenuation according to the detector thickness has fitted to a two-exponential function: relative height pulse = 0,519 e -0.0016 + 0.481 e -0.02112.x . Four radioactive sources 2 2 Na, 54 Mn, 137 Cs and 131 I were used to evaluate the performance of this system. The Compton reduction factor, determined by the ratio of the energy peak values of suppressed and unsuppressed spectra was 1.16. The Compton suppression factor determined by the ratio of the net photopeak area to the area of an equal spectra width in the Compton continuum, was approximately 1.208 ± 0.109. The sensitivity of the system, defined as the least amount of a radioactivity that can be quantified in the photopeak region, was 9.44 cps. First, the detector was assembled to be applied in biological studies of whole body counter measurements of small animals. Using a phantom, (small animal simulator) and a punctual 137 Cs source, located in the central region of the well counter the geometrical efficiency detector was about 5%. (author)

  9. Experimental Platform for Ultra-high Dose Rate FLASH Irradiation of Small Animals Using a Clinical Linear Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Schüler, Emil; Trovati, Stefania; King, Gregory; Lartey, Frederick; Rafat, Marjan; Villegas, Manuel; Praxel, A. Joe [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Loo, Billy W., E-mail: BWLoo@stanford.edu [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Stanford Cancer Institute, Stanford University School of Medicine, Stanford, California (United States); Maxim, Peter G., E-mail: PMaxim@stanford.edu [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Stanford Cancer Institute, Stanford University School of Medicine, Stanford, California (United States)

    2017-01-01

    Purpose: A key factor limiting the effectiveness of radiation therapy is normal tissue toxicity, and recent preclinical data have shown that ultra-high dose rate irradiation (>50 Gy/s, “FLASH”) potentially mitigates this effect. However, research in this field has been strongly limited by the availability of FLASH irradiators suitable for small animal experiments. We present a simple methodologic approach for FLASH electron small animal irradiation with a clinically available linear accelerator (LINAC). Methods and Materials: We investigated the FLASH irradiation potential of a Varian Clinac 21EX in both clinical mode and after tuning of the LINAC. We performed detailed FLUKA Monte Carlo and experimental dosimetric characterization at multiple experimental locations within the LINAC head. Results: Average dose rates of ≤74 Gy/s were achieved in clinical mode, and the dose rate after tuning exceeded 900 Gy/s. We obtained 220 Gy/s at 1-cm depth for a >4-cm field size with 90% homogeneity throughout a 2-cm-thick volume. Conclusions: We present an approach for using a clinical LINAC for FLASH irradiation. We obtained dose rates exceeding 200 Gy/s after simple tuning of the LINAC, with excellent dosimetric properties for small animal experiments. This will allow for increased availability of FLASH irradiation to the general research community.

  10. Experimental Platform for Ultra-high Dose Rate FLASH Irradiation of Small Animals Using a Clinical Linear Accelerator.

    Science.gov (United States)

    Schüler, Emil; Trovati, Stefania; King, Gregory; Lartey, Frederick; Rafat, Marjan; Villegas, Manuel; Praxel, A Joe; Loo, Billy W; Maxim, Peter G

    2017-01-01

    A key factor limiting the effectiveness of radiation therapy is normal tissue toxicity, and recent preclinical data have shown that ultra-high dose rate irradiation (>50 Gy/s, "FLASH") potentially mitigates this effect. However, research in this field has been strongly limited by the availability of FLASH irradiators suitable for small animal experiments. We present a simple methodologic approach for FLASH electron small animal irradiation with a clinically available linear accelerator (LINAC). We investigated the FLASH irradiation potential of a Varian Clinac 21EX in both clinical mode and after tuning of the LINAC. We performed detailed FLUKA Monte Carlo and experimental dosimetric characterization at multiple experimental locations within the LINAC head. Average dose rates of ≤74 Gy/s were achieved in clinical mode, and the dose rate after tuning exceeded 900 Gy/s. We obtained 220 Gy/s at 1-cm depth for a >4-cm field size with 90% homogeneity throughout a 2-cm-thick volume. We present an approach for using a clinical LINAC for FLASH irradiation. We obtained dose rates exceeding 200 Gy/s after simple tuning of the LINAC, with excellent dosimetric properties for small animal experiments. This will allow for increased availability of FLASH irradiation to the general research community. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Microscopy of bacterial translocation during small bowel obstruction and ischemia in vivo – a new animal model

    Directory of Open Access Journals (Sweden)

    Hafner Mathias

    2002-08-01

    Full Text Available Abstract Background Existing animal models provide only indirect information about the pathogenesis of infections caused by indigenous gastrointestinal microflora and the kinetics of bacterial translocation. The aim of this study was to develop a novel animal model to assess bacterial translocation and intestinal barrier function in vivo. Methods In anaesthetized male Wistar rats, 0.5 ml of a suspension of green fluorescent protein-transfected E. coli was administered by intraluminal injection in a model of small bowel obstruction. Animals were randomly subjected to non-ischemic or ischemic bowel obstruction. Ischemia was induced by selective clamping of the terminal mesenteric vessels feeding the obstructed bowel loop. Time intervals necessary for translocation of E. coli into the submucosal stroma and the muscularis propria was assessed using intravital microscopy. Results Bacterial translocation into the submucosa and muscularis propria took a mean of 36 ± 8 min and 80 ± 10 min, respectively, in small bowel obstruction. Intestinal ischemia significantly accelerated bacterial translocation into the submucosa (11 ± 5 min, p E. coli were visible in frozen sections of small bowel, mesentery, liver and spleen taken two hours after E. coli administration. Conclusions Intravital microscopy of fluorescent bacteria is a novel approach to study bacterial translocation in vivo. We have applied this technique to define minimal bacterial transit time as a functional parameter of intestinal barrier function.

  12. Methane production and small intestinal bacterial overgrowth in children living in a slum.

    Science.gov (United States)

    Mello, Carolina Santos; Tahan, Soraia; Melli, Lígia Cristina F L; Rodrigues, Mirian Silva do Carmo; de Mello, Ricardo Martin Pereira; Scaletsky, Isabel Cristina Affonso; de Morais, Mauro Batista

    2012-11-07

    To analyze small intestinal bacterial overgrowth in school-aged children and the relationship between hydrogen and methane production in breath tests. This transversal study included 85 children residing in a slum and 43 children from a private school, all aged between 6 and 10 years, in Osasco, Brazil. For characterization of the groups, data regarding the socioeconomic status and basic housing sanitary conditions were collected. Anthropometric data was obtained in children from both groups. All children completed the hydrogen (H(2)) and methane (CH(4)) breath test in order to assess small intestinal bacterial overgrowth (SIBO). SIBO was diagnosed when there was an increase in H(2) ≥ 20 ppm or CH(4) ≥ 10 ppm with regard to the fasting value until 60 min after lactulose ingestion. Children from the slum group had worse living conditions and lower nutritional indices than children from the private school. SIBO was found in 30.9% (26/84) of the children from the slum group and in 2.4% (1/41) from the private school group (P = 0.0007). Greater hydrogen production in the small intestine was observed in children from the slum group when compared to children from the private school (P = 0.007). A higher concentration of hydrogen in the small intestine (P slum group with SIBO when compared to children from the slum group without SIBO. Methane production was observed in 63.1% (53/84) of the children from the slum group and in 19.5% (8/41) of the children from the private school group (P slum. Colonic production of hydrogen was lower in methane-producing children (P = 0.017). Children who live in inadequate environmental conditions are at risk of bacterial overgrowth and methane production. Hydrogen is a substrate for methane production in the colon.

  13. Richard Bradley: a unified, living agent theory of the cause of infectious diseases of plants, animals, and humans in the first decades of the 18th century.

    Science.gov (United States)

    Santer, Melvin

    2009-01-01

    During the years 1714 to 1721, Richard Bradley, who was later to become the first Professor of Botany at Cambridge University, proposed a unified, unique, living agent theory of the cause of infectious diseases of plants and animals and the plague of humans. Bradley's agents included microscopic organisms, revealed by the studies of Robert Hooke and Antony van Leeuwenhoek. His theory derived from his experimental studies of plants and their diseases and from microscopic observation of animalcules in different naturally occurring and artificial environments. He concluded that there was a microscopic world of "insects" that lived and reproduced under the appropriate conditions, and that infectious diseases of plants were caused by such "insects." Since there are structural and functional similarities between plants and animals, Bradley concluded that microscopic organisms caused human and animal infectious diseases as well. However, his living agent cause of infectious diseases was not accepted by the contemporary scientific society.

  14. Animal models

    DEFF Research Database (Denmark)

    Gøtze, Jens Peter; Krentz, Andrew

    2014-01-01

    In this issue of Cardiovascular Endocrinology, we are proud to present a broad and dedicated spectrum of reviews on animal models in cardiovascular disease. The reviews cover most aspects of animal models in science from basic differences and similarities between small animals and the human...

  15. Improved instrumentation for blood flow velocity measurements in the microcirculation of small animals

    International Nuclear Information System (INIS)

    Mesquita, Jayme Alves Jr. de; Bouskela, Eliete; Wajnberg, Eliane; Lopes de Melo, Pedro

    2007-01-01

    Microcirculation is the generic name of vessels with internal diameter less than 100 μm of the circulatory system, whose main functions are tissue nutrition and oxygen supply. In microcirculatory studies, it is important to know the amount of oxyhemoglobin present in the blood and how fast it is moving. The present work describes improvements introduced in a classical hardware-based instrument that has usually been used to monitor blood flow velocity in the microcirculation of small animals. It consists of a virtual instrument that can be easily incorporated into existing hardware-based systems, contributing to reduce operator related biases and allowing digital processing and storage. The design and calibration of the modified instrument are described as well as in vitro and in vivo results obtained with electrical models and small animals, respectively. Results obtained in in vivo studies showed that this new system is able to detect a small reduction in blood flow velocity comparing arteries and arterioles (p<0.002) and a further reduction in capillaries (p<0.0001). A significant increase in velocity comparing capillaries and venules (p<0.001) and venules and veins (p<0.001) was also observed. These results are in close agreement with biophysical principles. Moreover, the improvements introduced in the device allowed us to clearly observe changes in blood flow introduced by a pharmacological intervention, suggesting that the system has enough temporal resolution to track these microcirculatory events. These results were also in close conformity to physiology, confirming the high scientific potential of the modified system and indicating that this instrument can also be useful for pharmacological evaluations

  16. Discrete tomography in an in vivo small animal bone study.

    Science.gov (United States)

    Van de Casteele, Elke; Perilli, Egon; Van Aarle, Wim; Reynolds, Karen J; Sijbers, Jan

    2018-01-01

    This study aimed at assessing the feasibility of a discrete algebraic reconstruction technique (DART) to be used in in vivo small animal bone studies. The advantage of discrete tomography is the possibility to reduce the amount of X-ray projection images, which makes scans faster and implies also a significant reduction of radiation dose, without compromising the reconstruction results. Bone studies are ideal for being performed with discrete tomography, due to the relatively small number of attenuation coefficients contained in the image [namely three: background (air), soft tissue and bone]. In this paper, a validation is made by comparing trabecular bone morphometric parameters calculated from images obtained by using DART and the commonly used standard filtered back-projection (FBP). Female rats were divided into an ovariectomized (OVX) and a sham-operated group. In vivo micro-CT scanning of the tibia was done at baseline and at 2, 4, 8 and 12 weeks after surgery. The cross-section images were reconstructed using first the full set of projection images and afterwards reducing them in number to a quarter and one-sixth (248, 62, 42 projection images, respectively). For both reconstruction methods, similar changes in morphometric parameters were observed over time: bone loss for OVX and bone growth for sham-operated rats, although for DART the actual values were systematically higher (bone volume fraction) or lower (structure model index) compared to FBP, depending on the morphometric parameter. The DART algorithm was, however, more robust when using fewer projection images, where the standard FBP reconstruction was more prone to noise, showing a significantly bigger deviation from the morphometric parameters obtained using all projection images. This study supports the use of DART as a potential alternative method to FBP in X-ray micro-CT animal studies, in particular, when the number of projections has to be drastically minimized, which directly reduces

  17. Oxygen and animal evolution: Did a rise of atmospheric oxygen trigger the origin of animals?

    DEFF Research Database (Denmark)

    Mills, Daniel Brady; Canfield, Donald Eugene

    2014-01-01

    Recent studies challenge the classical view that the origin of animal life was primarily controlled by atmospheric oxygen levels. For example, some modern sponges, representing early-branching animals, can live under 200 times less oxygen than currently present in the atmosphere - levels commonly...... thought to have been maintained prior to their origination. Furthermore, it is increasingly argued that the earliest animals, which likely lived in low oxygen environments, played an active role in constructing the well-oxygenated conditions typical of the modern oceans. Therefore, while oxygen is still...

  18. 9 CFR 113.312 - Rabies Vaccine, Live Virus.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Rabies Vaccine, Live Virus. 113.312... Virus Vaccines § 113.312 Rabies Vaccine, Live Virus. Rabies Vaccine shall be prepared from virus-bearing... administration. (iii) Observe all animals for signs of rabies until scheduled time to sacrifice. If animals show...

  19. Animals Alive! An Ecological Guide to Animal Activities. Revised Edition.

    Science.gov (United States)

    Holley, Dennis

    This guide is designed to help teachers develop an inquiry-oriented program for studying the animal kingdom in which live animals are collected locally, studied, observed, and then released completely unharmed back into their natural habitats. This book addresses such concerns of life science teachers as the environmental soundness of methods and…

  20. Imaging of hypoxia in small animals with 18F fluoromisonidasole

    Directory of Open Access Journals (Sweden)

    Kilian Krzysztof

    2016-06-01

    Full Text Available A method of automated synthesis of [18F]fluoromisonidazole ([18F]FMISO for application in preclinical studies on small animals was presented. A remote-controlled synthesizer Synthra RNplus was used for nucleophilic substitution of NITTP (1′-(2′-nitro-1-imidazolyl-2-O-tetrahydropyranyl-3-O-toluenesulfonyl-propanediol with 18F anion. Labeling of 5 mg of precursor was performed in anhydrous acetonitrile at 100°C for 10 min, and the hydrolysis with HCl was performed at 100°C for 5 min. Final purification was done with high-performance liquid chromatography (HPLC and the radiochemical purity of radiotracer was higher than 99%. Proposed [18F]FMISO synthesis was used as a reliable tool in studies on hypoxia in Lewis lung carcinoma (LLC in mouse models.

  1. Simplified quantification of small animal [{sup 18}F]FDG PET studies using a standard arterial input function

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, Philipp T. [University Hospital Aachen, Department of Neurology, Aachen (Germany); Circiumaru, Valentina; Thomas, Daniel H. [University of Pennsylvania, Department of Radiology, Philadelphia (United States); Cardi, Christopher A.; Bal, Harshali; Acton, Paul D. [Thomas Jefferson University, Department of Radiology, Philadelphia (United States)

    2006-08-15

    Arterial input function (AIF) measurement for quantification of small animal PET studies is technically challenging and limited by the small blood volume of small laboratory animals. The present study investigated the use of a standard arterial input function (SAIF) to simplify the experimental procedure. Twelve [{sup 18}F]fluorodeoxyglucose ([{sup 18}F]FDG) PET studies accompanied by serial arterial blood sampling were acquired in seven male Sprague-Dawley rats under isoflurane anaesthesia without (every rat) and with additional (five rats) vibrissae stimulation. A leave-one-out procedure was employed to validate the use of a SAIF with individual scaling by one (1S) or two (2S) arterial blood samples. Automatic slow bolus infusion of [{sup 18}F]FDG resulted in highly similar AIF in all rats. The average differences of the area under the curve of the measured AIF and the individually scaled SAIF were 0.11{+-}4.26% and 0.04{+-}2.61% for the 1S (6-min sample) and the 2S (4-min/43-min samples) approach, respectively. The average differences between the cerebral metabolic rates of glucose (CMR{sub glc}) calculated using the measured AIF and the scaled SAIF were 1.31{+-}5.45% and 1.30{+-}3.84% for the 1S and the 2S approach, respectively. The use of a SAIF scaled by one or (preferably) two arterial blood samples can serve as a valid substitute for individual AIF measurements to quantify [{sup 18}F]FDG PET studies in rats. The SAIF approach minimises the loss of blood and should be ideally suited for longitudinal quantitative small animal [{sup 18}F]FDG PET studies. (orig.)

  2. Fungal Infections of the Central Nervous System in Small Animals: Clinical Features, Diagnosis, and Management.

    Science.gov (United States)

    Bentley, R Timothy; Taylor, Amanda R; Thomovsky, Stephanie A

    2018-01-01

    Small animal mycoses vary geographically. Different clinical presentations are seen in animals with infection of the central nervous system (CNS), including multifocal meningoencephalomyelitis, intracranial lesions that accompany sinonasal lesions, rapidly progressive ventriculitis, or solitary granuloma of the brain or spinal cord. Systemic, nasal, or extraneural clinical signs are common but, especially in granuloma cases, do not always occur. Surgery may have a diagnostic and therapeutic role in CNS granuloma. There have been recent advancements in serology. Fluconazole, voriconazole, and posaconazole cross the blood-brain barrier, but voriconazole is neurotoxic to cats. Liposomal and lipid-encapsulated formulations of amphotericin B are preferred. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Magnetic resonance imaging for precise radiotherapy of small laboratory animals

    Energy Technology Data Exchange (ETDEWEB)

    Frenzel, Thorsten [Universitaetsklinikum Hamburg-Eppendorf, Hamburg (Germany). Bereich Strahlentherapie; Universitaetsklinikum Hamburg-Eppendorf, Hamburg (Germany). Inst. fuer Anatomie und Experimentelle Morphologie; Kaul, Michael Gerhard; Ernst, Thomas Michael; Salamon, Johannes [Universitaetsklinikum Hamburg-Eppendorf, Hamburg (Germany). Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie; Jaeckel, Maria [Universitaetsklinikum Hamburg-Eppendorf, Hamburg (Germany). Klinik und Poliklinik fuer Strahlentherapie und Radioonkologie; Schumacher, Udo [Universitaetsklinikum Hamburg-Eppendorf, Hamburg (Germany). Inst. fuer Anatomie und Experimentelle Morphologie; Kruell, Andreas [Universitaetsklinikum Hamburg-Eppendorf, Hamburg (Germany). Bereich Strahlentherapie

    2017-05-01

    Radiotherapy of small laboratory animals (SLA) is often not as precisely applied as in humans. Here we describe the use of a dedicated SLA magnetic resonance imaging (MRI) scanner for precise tumor volumetry, radiotherapy treatment planning, and diagnostic imaging in order to make the experiments more accurate. Different human cancer cells were injected at the lower trunk of pfp/rag2 and SCID mice to allow for local tumor growth. Data from cross sectional MRI scans were transferred to a clinical treatment planning system (TPS) for humans. Manual palpation of the tumor size was compared with calculated tumor size of the TPS and with tumor weight at necropsy. As a feasibility study MRI based treatment plans were calculated for a clinical 6 MV linear accelerator using a micro multileaf collimator (μMLC). In addition, diagnostic MRI scans were used to investigate animals which did clinical poorly during the study. MRI is superior in precise tumor volume definition whereas manual palpation underestimates their size. Cross sectional MRI allow for treatment planning so that conformal irradiation of mice with a clinical linear accelerator using a μMLC is in principle feasible. Several internal pathologies were detected during the experiment using the dedicated scanner. MRI is a key technology for precise radiotherapy of SLA. The scanning protocols provided are suited for tumor volumetry, treatment planning, and diagnostic imaging.

  4. Biodiversity of animals that are living on the surface of soil under the forest stands surrounding Japan Cave of BKPH Nglerak, North Lawu, Karanganyar

    Directory of Open Access Journals (Sweden)

    DHINI WIJAYA

    2002-01-01

    Full Text Available The study of animal biodiversity that lived on the surface of soil under the stands forest surround Japan Cave BKPH Nglerak, North Lawu, Karanganyar has bee done. Observations were conducted in 6 stations of different stands of forest. Animals were caught by pit fall trap method. In each catching was found about 22 animals consisting of 6 families with Simpson’s diversity index of 0.5. The result of identification indicates that those animals belong to 4 classes: Insects (9 orders, Arachnids (2 orders, Diplopods (2 orders, and Crustacean (1 order. The most diverse animals was found in the habitat of pine stands while the lowest one found in the habitat of cultivated plants.

  5. SIC, an intracerebral radiosensitive probe for in vivo neuropharmacology investigations in small laboratory animals: theoretical considerations and practical characteristics

    Science.gov (United States)

    Pain, F.; Laniece, P.; Mastrippolito, R.; Charon, Y.; Comar, D.; Leviel, V.; Pujol, J. F.; Valentin, L.

    2000-02-01

    Although high-resolution tomographs provide a new approach that strongly simplifies the measurement of in vivo tracer biodistribution and kinetics in small animals, they suffer from an important drawback: the need for animal anesthesia or immobilization, which restricts the neurophysiological investigations. Furthermore, quantitative in vivo experiments realized on the brain sometimes only require a simple measurement of the radioactivity achieved on a few local points and do not necessarily imply the use of a tomograph, which is a detector of high cost. These constraints led the authors to develop an interacerebral /spl beta/ sensitive probe, sonde intracerebrate (SIC) (French acronym of intracerebral probe) that will allow chronic measurements of the neurophysiological activity in awake and unrestrained small animals. The volume to which the probe is sensitive and the noise contributions to the relevant signal have been evaluated through Monte Carlo simulations. Characterizations of a first prototype based on a small piece of scintillating fiber (500-/spl mu/m diameter and 1-mm length) fused to a same diameter optical fiber coupled in turn to a photomultiplier are also presented. A first configuration of the detector is finally proposed.

  6. Effect of National Football League games on small animal emergency room caseload.

    Science.gov (United States)

    Rozanski, Elizabeth A; Rondeau, Mark P; Shaw, Scott P; Rush, John E

    2009-07-01

    To evaluate whether games of popular professional football teams have an effect on small animal emergency room caseload and percentage of dogs and cats that subsequently are hospitalized, are euthanatized, or die following admission to veterinary emergency rooms located within a dedicated fan base. Prospective study. 818 dogs and cats admitted to the emergency room. During the 2007 New England Patriots (NEP) football season, small animal emergency room caseload was recorded for Sunday (4-hour blocks, 8:00 AM until 12:00 midnight) and Monday night (7:00 PM to 11:00 PM). Number of dogs and cats that subsequently were hospitalized, died, or were euthanatized was recorded. Mean game importance rating (GIR) was determined for NEP games (scale, 1 [mild] to 3 [great]). Percentage of dogs and cats admitted from 12:00 noon to 4:00 PM on Sundays during NEP games (mean GIR, 1.7) versus non-NEP games was not different. Mean +/- SD percentage of dogs and cats admitted from 4:00 PM to 8:00 PM on Sundays during NEP games (mean GIR, 2.4) versus non-NEP games was significantly different (18 +/- 5% and 25 +/- 7% of daily caseload, respectively). Percentage of dogs and cats admitted from 8:00 PM to 12:00 midnight on Sundays during NEP games (mean GIR, 2.1) versus non-NEP games was not different. Game type (NEP vs non-NEP) during emergency room admission did not influence whether dogs and cats subsequently were hospitalized, died, or were euthanatized. Professional sporting events may influence veterinary emergency room caseloads.

  7. Effect of the animals on the soil

    International Nuclear Information System (INIS)

    Bonilla Correa, Carmen Rosa

    2000-01-01

    Soil is defined here in terms of opposite arbitrary frontiers more than its functions. The animals of the soil are defined in relation to their effect on the soil. The animals that live in the soil and intimately related to they are part of the soil. The animals that live on the soil make him contributions. Many animals are anphi-habitants, that is to say, they live in the soil and a one atmosphere outside of the soil. Animal exopedonics (outside of the soil) and endopedonics (inside the soil) they are considered with regard to twelve activities: blended, accumulation, formation of pores, obstruction of pores, formation and peds destruction, regulation of the erosion of the soil, regulation of the movement of air and the soil, regulation of the liter of plants, regulation of the animal liter, regulation of the cycle of nutritious, regulation of the biota and production of element special. The animals participate in numerous processes of formation of the soil and they affect the use of the same one

  8. Position-Sensitive Detector with Depth-of-Interaction Determination for Small Animal PET

    CERN Document Server

    Fedorov, A; Kholmetsky, A L; Korzhik, M V; Lecoq, P; Lobko, A S; Missevitch, O V; Tkatchev, A

    2002-01-01

    Crystal arrays made of LSO and LuAP crystals 2x2x10 mm pixels were manufactured for evaluation of detector with depth-of-interaction (DOI) determination capability intended for small animal positron emission tomograph. Position-sensitive LSO/LuAP phoswich DOI detector based on crystal 8x8 arrays and HAMAMATSU R5900-00-M64 position-sensitive multi-anode photomultiplier tube was developed and evaluated. Time resolution was found to be not worse than 1.0 ns FWHM for both layers, and spatial resolution mean value was 1.5 mm FWHM for the center of field-of-view.

  9. Sci-Thur AM: YIS – 08: Automated Imaging Quality Assurance for Image-Guided Small Animal Irradiators

    Energy Technology Data Exchange (ETDEWEB)

    Johnstone, Chris; Bazalova-Carter, Magdalena [University of Victoria (Australia)

    2016-08-15

    Purpose: To develop quality assurance (QA) standards and tolerance levels for image quality of small animal irradiators. Methods: A fully automated in-house QA software for image analysis of a commercial microCT phantom was created. Quantitative analyses of CT linearity, signal-to-noise ratio (SNR), uniformity and noise, geometric accuracy, modulation transfer function (MTF), and CT number evaluation was performed. Phantom microCT scans from seven institutions acquired with varying parameters (kVp, mA, time, voxel size, and frame rate) and five irradiator units (Xstrahl SARRP, PXI X-RAD 225Cx, PXI X-RAD SmART, GE explore CT/RT 140, and GE Explore CT 120) were analyzed. Multi-institutional data sets were compared using our in-house software to establish pass/fail criteria for each QA test. Results: CT linearity (R2>0.996) was excellent at all but Institution 2. Acceptable SNR (>35) and noise levels (<55HU) were obtained at four of the seven institutions, where failing scans were acquired with less than 120mAs. Acceptable MTF (>1.5 lp/mm for MTF=0.2) was obtained at all but Institution 6 due to the largest scan voxel size (0.35mm). The geometric accuracy passed (<1.5%) at five of the seven institutions. Conclusion: Our QA software can be used to rapidly perform quantitative imaging QA for small animal irradiators, accumulate results over time, and display possible changes in imaging functionality from its original performance and/or from the recommended tolerance levels. This tool will aid researchers in maintaining high image quality, enabling precise conformal dose delivery to small animals.

  10. Sci-Thur AM: YIS – 08: Automated Imaging Quality Assurance for Image-Guided Small Animal Irradiators

    International Nuclear Information System (INIS)

    Johnstone, Chris; Bazalova-Carter, Magdalena

    2016-01-01

    Purpose: To develop quality assurance (QA) standards and tolerance levels for image quality of small animal irradiators. Methods: A fully automated in-house QA software for image analysis of a commercial microCT phantom was created. Quantitative analyses of CT linearity, signal-to-noise ratio (SNR), uniformity and noise, geometric accuracy, modulation transfer function (MTF), and CT number evaluation was performed. Phantom microCT scans from seven institutions acquired with varying parameters (kVp, mA, time, voxel size, and frame rate) and five irradiator units (Xstrahl SARRP, PXI X-RAD 225Cx, PXI X-RAD SmART, GE explore CT/RT 140, and GE Explore CT 120) were analyzed. Multi-institutional data sets were compared using our in-house software to establish pass/fail criteria for each QA test. Results: CT linearity (R2>0.996) was excellent at all but Institution 2. Acceptable SNR (>35) and noise levels (<55HU) were obtained at four of the seven institutions, where failing scans were acquired with less than 120mAs. Acceptable MTF (>1.5 lp/mm for MTF=0.2) was obtained at all but Institution 6 due to the largest scan voxel size (0.35mm). The geometric accuracy passed (<1.5%) at five of the seven institutions. Conclusion: Our QA software can be used to rapidly perform quantitative imaging QA for small animal irradiators, accumulate results over time, and display possible changes in imaging functionality from its original performance and/or from the recommended tolerance levels. This tool will aid researchers in maintaining high image quality, enabling precise conformal dose delivery to small animals.

  11. Commodifying animals: ethical issues in genetic engineering of animals.

    Science.gov (United States)

    Almond, B

    2000-03-01

    The genetic modification of living beings raises special ethical concerns which go beyond general discussion of animal rights or welfare. Although the goals may be similar, biotechnology has accelerated the process of modification of types traditionally carried out by cross-breeding. These changes are discussed in relation to two areas: biomedicine, and animal husbandry. Alternative ethical approaches are reviewed, and it is argued that the teleological thesis underlying virtue ethics has special relevance here. The case for and the case against genetic engineering and patenting of life-forms are examined, and conclusions are drawn which favour regulation, caution and respect for animals and animal species.

  12. Concept and use of reference animals and plants

    International Nuclear Information System (INIS)

    Pentreath, R.J.

    2005-01-01

    In order to manage the exposure of human beings to ionizing radiation, a device was needed that enabled exposures to be related to dose received, and hence for relating doses to effects. The result was an entity called Reference Man. It has therefore been argued that a similar approach could prove useful in attempting to manage radionuclides in the environment by having a framework with which to relate exposures to dose, and doses to effects, for other types of living things, by way of a set of entities called reference animals and plants. This set would necessarily be limited in scope, because it is clearly not possible even to try to encompass the vast array of living things that might need to be considered in various forms of environmental management practices. Nevertheless, a relatively small set could still be useful in drawing out many of the basic questions, and to serve as a reference against which other forms of animals and plants could be compared. This paper outlines some of the issues involved and makes some suggestions as to how they might be addressed. (author)

  13. Experimental task-based optimization of a four-camera variable-pinhole small-animal SPECT system

    Science.gov (United States)

    Hesterman, Jacob Y.; Kupinski, Matthew A.; Furenlid, Lars R.; Wilson, Donald W.

    2005-04-01

    We have previously utilized lumpy object models and simulated imaging systems in conjunction with the ideal observer to compute figures of merit for hardware optimization. In this paper, we describe the development of methods and phantoms necessary to validate or experimentally carry out these optimizations. Our study was conducted on a four-camera small-animal SPECT system that employs interchangeable pinhole plates to operate under a variety of pinhole configurations and magnifications (representing optimizable system parameters). We developed a small-animal phantom capable of producing random backgrounds for each image sequence. The task chosen for the study was the detection of a 2mm diameter sphere within the phantom-generated random background. A total of 138 projection images were used, half of which included the signal. As our observer, we employed the channelized Hotelling observer (CHO) with Laguerre-Gauss channels. The signal-to-noise (SNR) of this observer was used to compare different system configurations. Results indicate agreement between experimental and simulated data with higher detectability rates found for multiple-camera, multiple-pinhole, and high-magnification systems, although it was found that mixtures of magnifications often outperform systems employing a single magnification. This work will serve as a basis for future studies pertaining to system hardware optimization.

  14. Bioorthogonal cyclization-mediated in situ self-assembly of small-molecule probes for imaging caspase activity in vivo

    Science.gov (United States)

    Ye, Deju; Shuhendler, Adam J.; Cui, Lina; Tong, Ling; Tee, Sui Seng; Tikhomirov, Grigory; Felsher, Dean W.; Rao, Jianghong

    2014-06-01

    Directed self-assembly of small molecules in living systems could enable a myriad of applications in biology and medicine, and already this has been used widely to synthesize supramolecules and nano/microstructures in solution and in living cells. However, controlling the self-assembly of synthetic small molecules in living animals is challenging because of the complex and dynamic in vivo physiological environment. Here we employ an optimized first-order bioorthogonal cyclization reaction to control the self-assembly of a fluorescent small molecule, and demonstrate its in vivo applicability by imaging caspase-3/7 activity in human tumour xenograft mouse models of chemotherapy. The fluorescent nanoparticles assembled in situ were imaged successfully in both apoptotic cells and tumour tissues using three-dimensional structured illumination microscopy. This strategy combines the advantages offered by small molecules with those of nanomaterials and should find widespread use for non-invasive imaging of enzyme activity in vivo.

  15. 9 CFR 113.300 - General requirements for live virus vaccines.

    Science.gov (United States)

    2010-01-01

    ... vaccines. 113.300 Section 113.300 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE... REQUIREMENTS Live Virus Vaccines § 113.300 General requirements for live virus vaccines. When prescribed in an applicable Standard Requirement or in the filed Outline of Production, a live virus vaccine shall meet the...

  16. Feeding strategies for improving milk production from milch animals owned by small farmers in India

    International Nuclear Information System (INIS)

    Leng, R.A.

    1990-01-01

    Over the last decade the National Dairy Development Board of India has researched and developed feeding strategies for lactating cattle and buffaloes fed on basal forage diets. Depending on the season and climate, these diets are largely mature forage from tropical pastures or crop residues, which are generally low in protein and of relatively low digestibility. Supplementation of the rumen microbial ecosystem with essential nutrients by providing each animal with a urea/molasses block stimulates production by improving feed digestibility, intake and the balance of nutrients available from the feed. Supplementation with a bypass protein to supply the animal directly with additional amino acids stimulates the efficiency of feed utilization by reducing the heat increment of feeding. In hot environments this reduces heat stress and allows feed intake to be maintained. These feeding strategies are now being applied to a large number of milch animals in the herds of small farmers in India. (author). 16 refs, 1 fig., 7 tabs

  17. Two-photon imaging of formaldehyde in live cells and animals utilizing a lysosome-targetable and acidic pH-activatable fluorescent probe.

    Science.gov (United States)

    Xie, Xilei; Tang, Fuyan; Shangguan, Xiaoyan; Che, Shiyi; Niu, Jinye; Xiao, Yongsheng; Wang, Xu; Tang, Bo

    2017-06-13

    Lyso-TPFP presents lysosomal targetability and an acidic pH-activatable response toward formaldehyde. Thus, it exclusively visualizes lysosomal formaldehyde and is immune against it in neutral cytosol and other organelles. In addition, two-photon fluorescence imaging endows Lyso-TPFP with the capability of in situ tracking formaldehyde in live cells and animals.

  18. An Exploratory Study of a New Educational Method Using Live Animals and Visual Thinking Strategies for Natural Science Teaching in Museums

    Science.gov (United States)

    Genovesi, Jacqueline Sue

    2011-01-01

    The earth is in an environmental crisis that can only be addressed by changing human conservation attitudes. People must have the scientific knowledge to make informed decisions. Research identifying new promising practices, for the use of live animals that incorporate new theories of learning and factors proven to impact learning, is critical. …

  19. Work environment and occupational risk assessment for small animal Portuguese veterinary activities.

    Science.gov (United States)

    Macedo, Angela C; Mota, Vânia T; Tavares, João M; Machado, Osvaldo L; Malcata, Francisco X; Cristo, Marinela P; Mayan, Olga N

    2018-03-01

    The professional work of small animal veterinary staff encompasses a wide diversity of demanding tasks. This has prompted a number of studies covering physical, chemical, biological, ergonomic, or psychological hazards, as well as their health effects upon veterinary workers. However, such results were obtained from self-reported surveys (via paper or online). This study reports the identification of potential hazards and provides a risk assessment of 15 veterinary clinics based on data from walk-through surveys, interviews with workers, and quantification of indoor air quality parameters including concentration of volatile organic compounds (total, isoflurane, and glutaraldehyde). The risk arising from X-ray exposure was unacceptable in seven clinics; X-ray examination should be discontinued in the absence of isolated radiation rooms, poor safety practices, and lack of personal protective equipment. Ergonomic-related hazards and work practices should be revised as soon as possible, considering that improper postures, as well as moving and lifting heavy animals are major causes of musculoskeletal disorders. The risk levels were, in general, small or medium (acceptable) with regard to exposure to physical hazards (such as bites, scratches, cuts, and burns) and biological hazards. It was observed that the indoor air quality parameters including temperature, respirable particulate matter and total volatile organic compounds do not indicate a comfortable workplace environment, requiring clinics' attention to keep the safe environment. The veterinarians and nurses were exposed to isoflurane (above 2 ppm) during surgery if an extractor system for waste gas was used instead of a scavenging system. Finally, veterinary workers did not possess any type of training on occupational safety and health issues, even though they recognized its importance.

  20. 9 CFR 201.108-1 - Instructions for weighing live poultry.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Instructions for weighing live poultry... STOCKYARDS ACT Poultry-Packers and Live Poultry Dealers § 201.108-1 Instructions for weighing live poultry. Live poultry dealers who operate scales on which live poultry is weighed for purposes of purchase, sale...

  1. Feasibility of small animal cranial irradiation with the microRT system

    International Nuclear Information System (INIS)

    Kiehl, Erich L.; Stojadinovic, Strahinja; Malinowski, Kathleen T.; Limbrick, David; Jost, Sarah C.; Garbow, Joel R.; Rubin, Joshua B.; Deasy, Joseph O.; Khullar, Divya; Izaguirre, Enrique W.; Parikh, Parag J.; Low, Daniel A.; Hope, Andrew J.

    2008-01-01

    Purpose: To develop and validate methods for small-animal CNS radiotherapy using the microRT system. Materials and Methods: A custom head immobilizer was designed and built to integrate with a pre-existing microRT animal couch. The Delrin couch-immobilizer assembly, compatible with multiple imaging modalities (CT, microCT, microMR, microPET, microSPECT, optical), was first imaged via CT in order to verify the safety and reproducibility of the immobilization method. Once verified, the subject animals were CT-scanned while positioned within the couch-immobilizer assembly for treatment planning purposes. The resultant images were then imported into CERR, an in-house-developed research treatment planning system, and registered to the microRTP treatment planning space using rigid registration. The targeted brain was then contoured and conformal radiotherapy plans were constructed for two separate studies: (1) a whole-brain irradiation comprised of two lateral beams at the 90 degree sign and 270 degree sign microRT treatment positions and (2) a hemispheric (left-brain) irradiation comprised of a single A-P vertex beam at the 0 degree sign microRT treatment position. During treatment, subject animals (n=48) were positioned to the CERR-generated treatment coordinates using the three-axis microRT motor positioning system and were irradiated using a clinical Ir-192 high-dose-rate remote after-loading system. The radiation treatment course consisted of 5 Gy fractions, 3 days per week. 90% of the subjects received a total dose of 30 Gy and 10% received a dose of 60 Gy. Results: Image analysis verified the safety and reproducibility of the immobilizer. CT scans generated from repeated reloading and repositioning of the same subject animal in the couch-immobilizer assembly were fused to a baseline CT. The resultant analysis revealed a 0.09 mm average, center-of-mass translocation and negligible volumetric error in the contoured, murine brain. The experimental use of the head

  2. CT with a CMOS flat panel detector integrated on the YAP-(S)PET scanner for in vivo small animal imaging

    International Nuclear Information System (INIS)

    Di Domenico, Giovanni; Cesca, Nicola; Zavattini, Guido; Auricchio, Natalia; Gambaccini, Mauro

    2007-01-01

    Several research groups are pursuing multimodality simultaneous functional and morphological imaging. In this line of research the high resolution YAP-(S)PET small animal integrated PET-SPECT imaging system, constructed by our group of medical physics at the University of Ferrara, is being upgraded with a computed tomography (CT). In this way it will be possible to perform in vivo molecular and genomic imaging studies on small animals (such as mice and rats) and at the same time obtain morphological information necessary for both attenuation correction and accurate localization of the region under investigation. We have take simultaneous PET-CT and SPECT-CT images of phantoms obtained with a single scanner

  3. Small-animal SPECT and SPECT/CT: application in cardiovascular research

    Energy Technology Data Exchange (ETDEWEB)

    Golestani, Reza; Dierckx, Rudi A.J.O. [University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); Wu, Chao [University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); University Medical Center Utrecht, Image Sciences Institute and Rudolf Magnus Institute of Neurosciences, Utrecht (Netherlands); Tio, Rene A. [University Medical Center Groningen, Thorax Center, Department of Cardiology, Groningen (Netherlands); University Medical Center Groningen, Cardiovascular Imaging Group, P.O. Box 30001, Groningen (Netherlands); Zeebregts, Clark J. [University Medical Center Groningen, Department of Surgery, Division of Vascular Surgery, Groningen (Netherlands); University Medical Center Groningen, Cardiovascular Imaging Group, P.O. Box 30001, Groningen (Netherlands); Petrov, Artiom D. [University of California, Irvine, Division of Cardiology, School of Medicine, Irvine, California (United States); Beekman, Freek J. [University Medical Center Utrecht, Image Sciences Institute and Rudolf Magnus Institute of Neurosciences, Utrecht (Netherlands); Delft University of Technology, Faculty of Applied Sciences, Section Radiation Detection and Medical Imaging, Delft (Netherlands); MILabs, Utrecht (Netherlands); Boersma, Hendrikus H. [University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); University Medical Center Groningen, Department of Clinical and Hospital Pharmacy, Hanzeplein 1, P.O. Box 30001, Groningen (Netherlands); University Medical Center Groningen, Cardiovascular Imaging Group, P.O. Box 30001, Groningen (Netherlands); Slart, Riemer H.J.A. [University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); University Medical Center Groningen, Cardiovascular Imaging Group, P.O. Box 30001, Groningen (Netherlands)

    2010-09-15

    Preclinical cardiovascular research using noninvasive radionuclide and hybrid imaging systems has been extensively developed in recent years. Single photon emission computed tomography (SPECT) is based on the molecular tracer principle and is an established tool in noninvasive imaging. SPECT uses gamma cameras and collimators to form projection data that are used to estimate (dynamic) 3-D tracer distributions in vivo. Recent developments in multipinhole collimation and advanced image reconstruction have led to sub-millimetre and sub-half-millimetre resolution SPECT in rats and mice, respectively. In this article we review applications of microSPECT in cardiovascular research in which information about the function and pathology of the myocardium, vessels and neurons is obtained. We give examples on how diagnostic tracers, new therapeutic interventions, pre- and postcardiovascular event prognosis, and functional and pathophysiological heart conditions can be explored by microSPECT, using small-animal models of cardiovascular disease. (orig.)

  4. Small-animal SPECT and SPECT/CT: application in cardiovascular research

    International Nuclear Information System (INIS)

    Golestani, Reza; Dierckx, Rudi A.J.O.; Wu, Chao; Tio, Rene A.; Zeebregts, Clark J.; Petrov, Artiom D.; Beekman, Freek J.; Boersma, Hendrikus H.; Slart, Riemer H.J.A.

    2010-01-01

    Preclinical cardiovascular research using noninvasive radionuclide and hybrid imaging systems has been extensively developed in recent years. Single photon emission computed tomography (SPECT) is based on the molecular tracer principle and is an established tool in noninvasive imaging. SPECT uses gamma cameras and collimators to form projection data that are used to estimate (dynamic) 3-D tracer distributions in vivo. Recent developments in multipinhole collimation and advanced image reconstruction have led to sub-millimetre and sub-half-millimetre resolution SPECT in rats and mice, respectively. In this article we review applications of microSPECT in cardiovascular research in which information about the function and pathology of the myocardium, vessels and neurons is obtained. We give examples on how diagnostic tracers, new therapeutic interventions, pre- and postcardiovascular event prognosis, and functional and pathophysiological heart conditions can be explored by microSPECT, using small-animal models of cardiovascular disease. (orig.)

  5. A small-animal imaging system capable of multipinhole circular/helical SPECT and parallel-hole SPECT

    International Nuclear Information System (INIS)

    Qian Jianguo; Bradley, Eric L.; Majewski, Stan; Popov, Vladimir; Saha, Margaret S.; Smith, Mark F.; Weisenberger, Andrew G.; Welsh, Robert E.

    2008-01-01

    We have designed and built a small-animal single-photon emission computed tomography (SPECT) imaging system equipped with parallel-hole and multipinhole collimators and capable of circular or helical SPECT. Copper-beryllium parallel-hole collimators suitable for imaging the ∼35 keV photons from the decay of 125 I have been built and installed to achieve useful spatial resolution over a range of object-detector distances and to reduce imaging time on our dual-detector array. To address the resolution limitations in the parallel-hole SPECT and the sensitivity and limited field of view of single-pinhole SPECT, we have incorporated multipinhole circular and helical SPECT in addition to expanding the parallel-hole SPECT capabilities. The pinhole SPECT system is based on a 110 mm diameter circular detector equipped with a pixellated NaI(Tl) scintillator array (1x1x5 mm 3 /pixel). The helical trajectory is accomplished by two stepping motors controlling the rotation of the detector-support gantry and displacement of the animal bed along the axis of rotation of the gantry. Results obtained in SPECT studies of various phantoms show an enlarged field of view, very good resolution and improved sensitivity using multipinhole circular or helical SPECT. Collimators with one, three and five, 1-mm-diameter pinholes have been implemented and compared in these tests. Our objective is to develop a system on which one may readily select a suitable mode of either parallel-hole SPECT or pinhole circular or helical SPECT for a variety of small animal imaging applications

  6. Annular phased array transducer for preclinical testing of anti-cancer drug efficacy on small animals.

    Science.gov (United States)

    Kujawska, Tamara; Secomski, Wojciech; Byra, Michał; Postema, Michiel; Nowicki, Andrzej

    2017-04-01

    A technique using pulsed High Intensity Focused Ultrasound (HIFU) to destroy deep-seated solid tumors is a promising noninvasive therapeutic approach. A main purpose of this study was to design and test a HIFU transducer suitable for preclinical studies of efficacy of tested, anti-cancer drugs, activated by HIFU beams, in the treatment of a variety of solid tumors implanted to various organs of small animals at the depth of the order of 1-2cm under the skin. To allow focusing of the beam, generated by such transducer, within treated tissue at different depths, a spherical, 2-MHz, 29-mm diameter annular phased array transducer was designed and built. To prove its potential for preclinical studies on small animals, multiple thermal lesions were induced in a pork loin ex vivo by heating beams of the same: 6W, or 12W, or 18W acoustic power and 25mm, 30mm, and 35mm focal lengths. Time delay for each annulus was controlled electronically to provide beam focusing within tissue at the depths of 10mm, 15mm, and 20mm. The exposure time required to induce local necrosis was determined at different depths using thermocouples. Location and extent of thermal lesions determined from numerical simulations were compared with those measured using ultrasound and magnetic resonance imaging techniques and verified by a digital caliper after cutting the tested tissue samples. Quantitative analysis of the results showed that the location and extent of necrotic lesions on the magnetic resonance images are consistent with those predicted numerically and measured by caliper. The edges of lesions were clearly outlined although on ultrasound images they were fuzzy. This allows to conclude that the use of the transducer designed offers an effective noninvasive tool not only to induce local necrotic lesions within treated tissue without damaging the surrounding tissue structures but also to test various chemotherapeutics activated by the HIFU beams in preclinical studies on small animals

  7. A new tissue segmentation method to calculate 3D dose in small animal radiation therapy.

    Science.gov (United States)

    Noblet, C; Delpon, G; Supiot, S; Potiron, V; Paris, F; Chiavassa, S

    2018-02-26

    In pre-clinical animal experiments, radiation delivery is usually delivered with kV photon beams, in contrast to the MV beams used in clinical irradiation, because of the small size of the animals. At this medium energy range, however, the contribution of the photoelectric effect to absorbed dose is significant. Accurate dose calculation therefore requires a more detailed tissue definition because both density (ρ) and elemental composition (Z eff ) affect the dose distribution. Moreover, when applied to cone beam CT (CBCT) acquisitions, the stoichiometric calibration of HU becomes inefficient as it is designed for highly collimated fan beam CT acquisitions. In this study, we propose an automatic tissue segmentation method of CBCT imaging that assigns both density (ρ) and elemental composition (Z eff ) in small animal dose calculation. The method is based on the relationship found between CBCT number and ρ*Z eff product computed from known materials. Monte Carlo calculations were performed to evaluate the impact of ρZ eff variation on the absorbed dose in tissues. These results led to the creation of a tissue database composed of artificial tissues interpolated from tissue values published by the ICRU. The ρZ eff method was validated by measuring transmitted doses through tissue substitute cylinders and a mouse with EBT3 film. Measurements were compared to the results of the Monte Carlo calculations. The study of the impact of ρZ eff variation over the range of materials, from ρZ eff  = 2 g.cm - 3 (lung) to 27 g.cm - 3 (cortical bone) led to the creation of 125 artificial tissues. For tissue substitute cylinders, the use of ρZ eff method led to maximal and average relative differences between the Monte Carlo results and the EBT3 measurements of 3.6% and 1.6%. Equivalent comparison for the mouse gave maximal and average relative differences of 4.4% and 1.2%, inside the 80% isodose area. Gamma analysis led to a 94.9% success rate in the 10% isodose

  8. High-throughput screen for novel antimicrobials using a whole animal infection model.

    Science.gov (United States)

    Moy, Terence I; Conery, Annie L; Larkins-Ford, Jonah; Wu, Gang; Mazitschek, Ralph; Casadei, Gabriele; Lewis, Kim; Carpenter, Anne E; Ausubel, Frederick M

    2009-07-17

    The nematode Caenorhabditis elegans is a unique whole animal model system for identifying small molecules with in vivo anti-infective properties. C. elegans can be infected with a broad range of human pathogens, including Enterococcus faecalis, an important human nosocomial pathogen. Here, we describe an automated, high-throughput screen of 37,200 compounds and natural product extracts for those that enhance survival of C. elegans infected with E. faecalis. Using a robot to dispense live, infected animals into 384-well plates and automated microscopy and image analysis, we identified 28 compounds and extracts not previously reported to have antimicrobial properties, including six structural classes that cure infected C. elegans animals but do not affect the growth of the pathogen in vitro, thus acting by a mechanism of action distinct from antibiotics currently in clinical use.

  9. Dynamic 18F-fluoride small animal PET to noninvasively assess renal function in rats

    International Nuclear Information System (INIS)

    Schnoeckel, Uta; Stegger, Lars; Schaefers, Klaus P.; Hermann, Sven; Schober, Otmar; Schaefers, Michael; Reuter, Stefan; Schlatter, Eberhard; Gabriels, Gert

    2008-01-01

    Renal function can be quantified by both laboratory and scintigraphic methods. In the case of small animal diagnostics, scintigraphic image-based methods are ideal since they can assess split renal function, work noninvasively, and can be repeated. The aim of this study is to validate a 18 F-PET-based method to quantify renal function in rats. Fluoride clearance was calculated from a dynamic whole body listmode acquisition of 60 min length in a small animal PET scanner following an i.v. injection of 15 MBq 18 F-fluoride. Volumes of interest (VOIs) were placed in the left ventricle and the bladder as well as traced around the kidney contours. The respective time-activity curves (TAC) were calculated. The renal 18 F-clearance was calculated by the ratio of the total renal excreted activity (bladder VOI) and the integral of the blood TAC. PET-derived renal function was validated by intraindividual measurements of creatinine clearance (n=23), urea clearance (n=23), and tubular excretion rate (TER-MAG3). The split renal function was derived from the injection of the clinically available radionuclide 99m Tc-mercaptotriglycine by blood sampling and planar renography (n=8). In all animals studied, PET revealed high-quality TACs. PET-derived renal fluoride clearance was linearly correlated with intraindividual laboratory measures (PET vs. creatinine: r=0.78; PET vs. urea: r=0.73; PET vs. TER-MAG3: r=0.73). Split function was comparable ( 18 F-PET vs. MAG3-renography: r=0.98). PET-derived measures were highly reproducible. 18 F-PET is able to noninvasively assess renal function in rats and provides a significant potential for serial studies in different experimental scenarios. (orig.)

  10. Occupational therapists as dog handlers: the collective experience with animal-assisted therapy in Iraq.

    Science.gov (United States)

    Fike, Lorie; Najera, Cecilia; Dougherty, David

    2012-01-01

    The first pair of US Army animal-assisted therapy (AAT) dogs deployed to Iraq in December 2007 with the 85th Medical Detachment Combat and Operational Stress Control unit. As of this writing, 6 dogs have deployed to Iraq and Afghanistan, offering Soldiers a small reminder of home. Army occupational therapists led the way in this endeavor as primary handlers; the path has been rocky but ultimately rewarding. This article depicts how occupational therapists used AAT and animal-assisted activities to help Soldiers cope with the stressors of living in a deployed environment. Challenges and lessons-learned, including anecdotal examples, are discussed.

  11. Non-invasive 3D-microscopy with 10-μm spatial resolution inside alive small laboratory animals

    International Nuclear Information System (INIS)

    Sasov, A.; Dewaele, D.; De Clerck, N.

    2002-01-01

    Full text: Small laboratory animals (mice and rats) are widely used in development of drugs and treatments. Micro-CT or microtomography allows non-invasive 3D imaging and measurements of the microstructure inside the body of alive animals. To recognise the internal changes of bones and different organs in the very early stage, high-resolution micro-CT scanner for in-vivo 3D-imaging has been developed. The Micro-CT scanner based on the X-ray geometry with source-detector pair rotation around the object instead of object rotation geometry, typical for other micro-CT systems. Object illuminated by an X-ray source with 5 microns spot size and 20-100keV energies. X-ray images collected by a digital x-ray camera. Projection images with 8000x1000x16bit format collected from several hundreds angular projections. On the base of this information cross sectional images can be reconstructed in 8000x8000x32bit full format or 1024x1024x32bit preview. Maximum object size (scanning volume) is 80mm in diameter by 200mm in length with 10-microns isotropic pixel size for reconstruction at any place of this space. All software for system control, reconstruction and 3D analysis runs on Pentium-4 2GHz or Dual Intel Xeon 1.7GHz computer under Microsoft Windows-2000. The instrument is widely used for scanning of physical phantoms as well as different alive small laboratory animals under anesthesia. Achieved spatial resolution is 20microns for low-contrast objects and 10-microns for high-contrast objects (bone, etc.). Typical scanning time is 20-120min, typical irradiation dose - 0.25-0.7Gy per scan. To avoid movement artefacts from breathing, the instrument can synchronise acquisition cycle with pulses from special breathing sensor. Software package includes dual-processor reconstruction software, 3D-rendering and measurement of all general and bone-specific morphological parameters. New in-vivo Micro-CT scanner allows non-destructive 3D-imaging and measurements of the internal

  12. Investigation of incidence and risk factors for surgical glove perforation in small animal surgery.

    Science.gov (United States)

    Hayes, Galina M; Reynolds, Deborah; Moens, Noel M M; Singh, Ameet; Oblak, Michelle; Gibson, Thomas W G; Brisson, Brigitte A; Nazarali, Alim; Dewey, Cate

    2014-05-01

    To identify incidence and risk factors for surgical glove perforation in small animal surgery. Observational cohort study. Surgical gloves (n = 2132) worn in 363 surgical procedures. All gloves worn by operative personnel were assessed for perforation at end-procedure using a water leak test. Putative risk factors were recorded by a surgical team member. Associations between risk factors and perforation were assessed using multivariable multi-level random-effects logistic regression models to control for hierarchical data structure. At least 1 glove perforation occurred in 26.2% of procedures. Identified risk factors for glove perforation included increased surgical duration (surgery >1 hour OR = 1.79, 95% CI = 1.12-2.86), performing orthopedic procedures (OR = 1.88; 95% CI = 1.23-2.88), any procedure using powered instruments (OR = 1.93; 95% CI = 1.21-3.09) or surgical wire (OR = 3.02; 95% CI = 1.50-6.05), use of polyisoprene as a glove material (OR = 1.59, 95% CI = 1.05-2.39), and operative role as primary surgeon (OR = 2.01; 95% CI = 1.35-2.98). The ability of the wearer to detect perforations intraoperatively was poor, with a sensitivity of 30.8%. There is a high incidence of unrecognized glove perforations in small animal surgery. © Copyright 2014 by The American College of Veterinary Surgeons.

  13. Animal-Assisted Therapies and Dementia: A Systematic Mapping Review Using the Lived Environment Life Quality (LELQ) Model.

    Science.gov (United States)

    Wood, Wendy; Fields, Beth; Rose, Michelle; McLure, Merinda

    The authors mapped the literature on animal-assisted therapies (AATs) and institutionalized adults with dementia onto the Lived Environment Life Quality (LELQ) Model as a guide for future services and research. Refereed literature addressing AATs and institutionalized people with dementia was comprehensively gathered, described, categorized, and synthesized in this systematic mapping review. From 1,342 screened records, the authors included 10 research articles that incorporated dogs in therapy for institutionalized adults with dementia. These canine-assisted therapies offered occupational opportunities and environmental supports conducive to experiences of relative well-being, occupational engagement, and optimal functioning. The findings offer proof of the concept that canine-assisted therapies are feasible and can elicit positive quality-of-life experiences in institutionalized people with dementia. Researchers and practitioners need to elucidate the theoretical foundations of AATs. The LELQ Model may serve as a guide for client-centered, occupation-focused, and ecologically valid approaches to animal-assisted occupational therapy. Copyright © 2017 by the American Occupational Therapy Association, Inc.

  14. Experiences of adults who as children lived with a parent experiencing mental illness in a small-scale society : A Qualitative study.

    Science.gov (United States)

    Dam, K; Joensen, D G; Hall, E O C

    2018-03-01

    WHAT IS KNOWN ON THE SUBJECT?: Children of parent with severe mental illness are often carrying a caring burden; they keep the illness in the family, are documented to be stigmatized, bullied and to take special attention to their mentally ill parent's health and well-being. Little is however known about these children's experiences when growing up in a small-scale society. WHAT THIS STUDY ADDS TO EXISTING KNOWLEDGE?: Children's experiences of living with a parent with severe mental illness in the small-scale society (Faroe Islands) are paradoxical, life is often unreasonable and evidently contradictory but anyway connected. The results show that "everybody knows everybody" which refers to that, in the small-scale society, it is difficult to be anonymous. The children were familiar with that people talked and had a prejudiced attitude; this resulted that the participants were constantly reminded of their mental ill parent's difference, and they were feeling less worthy than their pals. Children of parents with severe mental illness in a small-scale society need to support from the close family as well as mental healthcare professionals. WHAT ARE THE IMPLICATIONS FOR PRACTICE?: The study adds knowledge about the challenges that children of mental ill parents have to go through. Dialogue among mental healthcare colleagues not only about caring for the sick parent but also about modes of caring for the children and the family at large would deepen the staff's knowing of the need for family-centred care within mental health care. Introduction An estimated 23% of children worldwide live with a parent experiencing mental illness. These children are exposed to emotional and psychosocial challenges. Little is known about these children when living in small-scale societies. Aim To explore how adults, who as children lived with parents experiencing mental illness in a small-scale society, recalled their childhood life. Method Individual interviews with 11 adults were

  15. Technical Note: System for evaluating local hypothermia as a radioprotector of the rectum in a small animal model.

    Science.gov (United States)

    Hrycushko, Brian A; Bing, Chenchen; Futch, Cecil; Wodzak, Michelle; Stojadinovic, Strahinja; Medin, Paul M; Chopra, Rajiv

    2017-08-01

    The protective effects of induced or even accidental hypothermia on the human body are widespread with several medical uses currently under active research. In vitro experiments using human cell lines have shown hypothermia provides a radioprotective effect that becomes more pronounced at large, single-fraction doses common to stereotactic body radiotherapy (SBRT) and stereotactic radiosurgery (SRS) treatments. This work describes the development of a system to evaluate local hypothermia for a radioprotective effect of the rat rectum during a large dose of radiation relevant to prostate SBRT. This includes the evaluation of a 3D-printed small animal rectal cooling device and the integration with a small animal irradiator. A 3-cm long, dual-lumen rectal temperature control apparatus (RTCA) was designed in SOLIDWORKS CAD for 3D printing. The RTCA was capable of recirculating flow in a device small enough for insertion into the rat rectum, with a metal support rod for strength as well as visibility during radiation treatment planning. The outer walls of the RTCA comprised of thin heat shrink plastic, achieving efficient heat transfer into adjacent tissues. Following leak-proof testing, fiber optic temperature probes were used to evaluate the temperature over time when placed adjacent to the cooling device within the rat rectum. MRI thermometry characterized the relative temperature distribution in concentric ROIs surrounding the probe. Integration with an image-guided small animal irradiator and associated treatment planning system included evaluation for imaging artifacts and effect of brass tubing on dose calculation. The rectal temperature adjacent to the cooling device decreased from body temperature to 15°C within 10-20 min from device insertion and was maintained at 15 ± 3°C during active cooling for the evaluated time of one hour. MR thermometry revealed a steep temperature gradient with increasing distance from the cooling device with the desired

  16. Natural infection by endoparasites among free-living wild animals Infecção natural por endoparasitas em animais silvestres de vida-livre

    Directory of Open Access Journals (Sweden)

    Luciane Holsback

    Full Text Available The objective of this study was to investigate the frequency of occurrence and variety of intestinal parasites among free-living wild animals. Fecal samples from wild mammals and birds at rehabilitation centers in the states of Mato Grosso do Sul and São Paulo were analyzed by sedimentation and flotation-centrifugation methods. Parasite eggs, oocysts, cysts and/or trophozoites were found in 71% of the samples. Cryptosporidium sp. oocysts were detected in fecal samples from oncillas (Leopardus tigrinus and scaly-headed parrots (Pionus maximiliani. Giardia cysts were identified in the feces of a gray brocket (Mazama gouazoubira. Among the most common parasites found, there were eggs from Toxocara cati, Toxascaris leonina and Ancylostoma tubaeforme, and from Cestoda. Several Enterobius sp. eggs were found in the feces of red howler monkeys (Alouatta seniculus. It can be concluded from this study that despite the small number of samples, the diversity of parasites found was noteworthy. Additional information about parasite endofauna in wild animals is needed, since their presence might suggest that there could be proximity to and interactions with domestic animals and/or humans. In addition, further studies on parasites from free-living wild animals are of prime importance for understanding the intensity of anthropic changes in wild environments.O objetivo deste trabalho foi pesquisar a frequência de ocorrência e a variedade de parasitas intestinais de animais silvestres de vida livre. Amostras de fezes de mamíferos e aves silvestres de centros de reabilitação dos Estados do Mato Grosso do Sul e São Paulo, foram analisadas pelos métodos de sedimentação e de centrífugo-flutuação. Foram encontrados ovos, oocistos, cistos e/ou trofozoítos de parasitas em 71% das amostras. Oocistos de Cryptosporidium sp. foram detectados em amostras de fezes de gato-do-mato-pequeno (Leopardus tigrinus e maritacas (Pionus maximiliani. Cistos de Giardia

  17. First llama (Lama glama) pregnancy obtained after in vitro fertilization and in vitro culture of gametes from live animals.

    Science.gov (United States)

    Trasorras, V; Baca Castex, C; Alonso, A; Giuliano, S; Santa Cruz, R; Arraztoa, C; Chaves, G; Rodríguez, D; Neild, D; Miragaya, M

    2014-07-01

    The aim of this study was to evaluate the developmental competence and pregnancy rate of llama hatched blastocysts produced in vitro using gametes from live animals and two different culture conditions. Fifteen adult females were superstimulated with 1500 IU of eCG, eleven (73%) responded to the treatment and were used as oocyte donors. Follicular aspiration was conducted by flank laparotomy. Semen collections were performed under general anesthesia by electroejaculation of the male. Sixty-six COCs were recovered from 77 aspirated follicles (86% recovery) and were randomly placed in Fertil-TALP microdroplets with the sperm suspension (20 × 10(6)live spermatozoa/ml). After 24 h, they were placed in SOFaa medium supplemented with FCS and randomly assigned to one of two culture conditions. Culture condition 1 (CC1) consisted of 6 days of culture (n=28) and culture condition 2 (CC2) consisted of renewing the culture medium every 48 h (n=35). In CC1, the blastocyst rate was 36% (10/28) and the hatched blastocyst rate was 28% (8/28) whereas in CC2, the blastocyst rate was 34% (12/35) and the hatched blastocyst rate was 20% (7/35) (p>0.05). No pregnancies were obtained after embryo transfer (ET) of CC1 blastocysts (0/8) while one pregnancy was obtained (1/7) after transferring a hatched blastocyst from CC2. Forty-two days after the ET, the pregnancy was lost. This study represents the first report of a pregnancy in the llama after intrauterine transfer of embryos produced by in vitro fertilization using gametes from live animals. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Progress on dedicated animal PET

    International Nuclear Information System (INIS)

    Liu Wei

    2002-01-01

    Positron emission tomography, as the leading technology providing molecular imaging of biological processes, is widely used on living laboratory animals. High-resolution dedicated animal PET scanners have been developed. Although the dedicated animal PET faces obstacles and challenges, this advanced technology would play an important role in molecular biomedicine researches, such as diseases study, medicine development, and gene therapy

  19. Animals living in polluted environments are potential source of antimicrobials against infectious agents

    Science.gov (United States)

    Lee, Simon; Siddiqui, Ruqaiyyah; Khan, Naveed Ahmed

    2012-01-01

    The antimicrobials crisis is a ticking time bomb which could lead to millions of people dying from untreatable infections. With the worsening trends of antimicrobial resistance, we are heading towards a pre-antibiotic era. Thus, there is a need for newer and more powerful antibiotic agents. The search for new antibiotic compounds originating from natural resources is a promising research area. Animals living in germ-infested environments are a potent source of antimicrobials. Under polluted milieus, organisms such as cockroaches encounter different types of bacteria, including superbugs. Such creatures survive the onslaught of superbugs and are able to ward off disease by producing antimicrobial substances which show potent activity in the nervous system. We hope that the discovery of antimicrobial activity in the cockroach brain will stimulate research in finding antimicrobials from unusual sources, and has potential for the development of novel antibiotics. Nevertheless, intensive research in the next few years will be required to approach or realize these expectations. PMID:23265422

  20. A closed cabinet system with water flushers and a blender for breeding small animal administered 3HHO

    International Nuclear Information System (INIS)

    Yamamoto, O.; Takeoka, S.; Tsujimura, T.; Kuroda, T.; Iwashita, T.; Amme, T.

    1984-01-01

    A closed cabinet system was developed for breeding small animals administered 3 HHO. 3 HHO vapor released from the animals in the chamber was absorbed with water in a water bubbler. Feces and urine which were washed out with water were ground in a blender, diluted, and then released. With this cabinet system we were successful in safely breeding mice even given a total single injection of 15.5 GBq (420 mCi) of 3 HHO without storing the 3 H-slops for a long time and without any significant leakage of 3 H from the cabinet. (author)

  1. Attenuation correction for the NIH ATLAS small animal PET scanner

    CERN Document Server

    Yao, Rutao; Liow, JeihSan; Seidel, Jurgen

    2003-01-01

    We evaluated two methods of attenuation correction for the NIH ATLAS small animal PET scanner: 1) a CT-based method that derives 511 keV attenuation coefficients (mu) by extrapolation from spatially registered CT images; and 2) an analytic method based on the body outline of emission images and an empirical mu. A specially fabricated attenuation calibration phantom with cylindrical inserts that mimic different body tissues was used to derive the relationship to convert CT values to (I for PET. The methods were applied to three test data sets: 1) a uniform cylinder phantom, 2) the attenuation calibration phantom, and 3) a mouse injected with left bracket **1**8F right bracket FDG. The CT-based attenuation correction factors were larger in non-uniform regions of the imaging subject, e.g. mouse head, than the analytic method. The two methods had similar correction factors for regions with uniform density and detectable emission source distributions.

  2. Design considerations and construction of a small animal PET prototype

    International Nuclear Information System (INIS)

    Tzanakos, G.; Nikolaou, M.; Drakoulakos, D.; Karamitros, D.; Kontaxakis, G.; Logaras, E.; Panayiotakis, G.; Pavlopoulos, S.; Skiadas, M.; Spyrou, G.; Thireou, T.; Vamvakas, D.

    2006-01-01

    We are developing a small animal PET scanner consisting of two block detectors, each made of 216 BGO crystals of dimensions 3.75 mmx3.75 mmx20 mm, cylindrically arranged and coupled to a position-sensitive photomultiplier tube (R2486 PSPMT). Our design was based on a very detailed Monte Carlo, that simulates the function of a PET scanner from the system level down to the individual γ-ray detectors. We have made laboratory measurements of the individual detector performance as well as measurements of characteristics of the PSPMTs. The two detector blocks which will form the basic tomographic unit have been assembled. We are developing electronics to individually process (amplify and digitize) anode signals, and use field programmable gate arrays (FPGAs) in the position determination and energy measurement of the γ-rays. At present, as an intermediate step, we are using the electronics supplied from Hamamatsu to study various aspects of the system and produce initial images

  3. Imaging modalities used to confirm diaphragmatic hernia in small animals

    International Nuclear Information System (INIS)

    Williams, J.; Leveille, R.; Myer, C.W.

    1998-01-01

    When a patient is presented for treatment following a traumatic accident such as being hit by a car, thoracic radiographs are usually an integral part of the overall diagnostic evaluation. Diagnosis at diaphragmatic hernia (DH) is often challenging in small animals. The thorax may contain substantial fluid, thereby masking the presence of cranially displaced abdominal soft tissues (e.g., liver or spleen). The most common cause of decreased radiographic visualization of the diaphragm on survey radiographs is pleural fluid; however, the second most common cause is DH. Obviously, if a gas-filledviscus is identified within the thoracic cavity on survey radiographs, the diagnosis of DH is straightforward and relatively routine. If, however, there is substantial pleural effusion and the herniated structure is a soft tissue parenchymal organ (e.g., liver or spleen), the diagnosis is less clearly defined on survey radiographs. This review discusses the various imaging modalities (survey, positional, and contrast-enhanced radiographs and ultrasonography) that can be used in the diagnosis or confirmation of DH

  4. Small animal simultaneous PET/MRI: initial experiences in a 9.4 T microMRI

    Energy Technology Data Exchange (ETDEWEB)

    Maramraju, Sri Harsha; Ravindranath, Bosky; Vaska, Paul; Schlyer, David J [Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY (United States); Smith, S David; Schulz, Daniela [Medical Department, Brookhaven National Laboratory, Upton, NY (United States); Junnarkar, Sachin S; Rescia, Sergio [Instrumentation Division, Brookhaven National Laboratory, Upton, NY (United States); Stoll, Sean; Purschke, Martin L; Woody, Craig L [Physics Department, Brookhaven National Laboratory, Upton, NY (United States); Southekal, Sudeepti [Brigham and Women' s Hospital, Boston, MA (United States); Pratte, Jean-Francois, E-mail: schlyer@bnl.gov [Universite de Sherbrooke, Sherbrooke, Quebec (Canada)

    2011-04-21

    We developed a non-magnetic positron-emission tomography (PET) device based on the rat conscious animal PET that operates in a small-animal magnetic resonance imaging (MRI) scanner, thereby enabling us to carry out simultaneous PET/MRI studies. The PET detector comprises 12 detector blocks, each being a 4 x 8 array of lutetium oxyorthosilicate crystals (2.22 x 2.22 x 5 mm{sup 3}) coupled to a matching non-magnetic avalanche photodiode array. The detector blocks, housed in a plastic case, form a 38 mm inner diameter ring with an 18 mm axial extent. Custom-built MRI coils fit inside the positron-emission tomography (PET) device, operating in transceiver mode. The PET insert is integrated with a Bruker 9.4 T 210 mm clear-bore diameter MRI scanner. We acquired simultaneous PET/MR images of phantoms, of in vivo rat brain, and of cardiac-gated mouse heart using [{sup 11}C]raclopride and 2-deoxy-2-[{sup 18}F]fluoro-d-glucose PET radiotracers. There was minor interference between the PET electronics and the MRI during simultaneous operation, and small effects on the signal-to-noise ratio in the MR images in the presence of the PET, but no noticeable visual artifacts. Gradient echo and high-duty-cycle spin echo radio frequency (RF) pulses resulted in a 7% and a 28% loss in PET counts, respectively, due to high PET counts during the RF pulses that had to be gated out. The calibration of the activity concentration of PET data during MR pulsing is reproducible within less than 6%. Our initial results demonstrate the feasibility of performing simultaneous PET and MRI studies in adult rats and mice using the same PET insert in a small-bore 9.4 T MRI.

  5. Three-dimensional segmentation and skeletonization to build an airway tree data structure for small animals

    International Nuclear Information System (INIS)

    Chaturvedi, Ashutosh; Lee, Zhenghong

    2005-01-01

    Quantitative analysis of intrathoracic airway tree geometry is important for objective evaluation of bronchial tree structure and function. Currently, there is more human data than small animal data on airway morphometry. In this study, we implemented a semi-automatic approach to quantitatively describe airway tree geometry by using high-resolution computed tomography (CT) images to build a tree data structure for small animals such as rats and mice. Silicon lung casts of the excised lungs from a canine and a mouse were used for micro-CT imaging of the airway trees. The programming language IDL was used to implement a 3D region-growing threshold algorithm for segmenting out the airway lung volume from the CT data. Subsequently, a fully-parallel 3D thinning algorithm was implemented in order to complete the skeletonization of the segmented airways. A tree data structure was then created and saved by parsing through the skeletonized volume using the Python programming language. Pertinent information such as the length of all airway segments was stored in the data structure. This approach was shown to be accurate and efficient for up to six generations for the canine lung cast and ten generations for the mouse lung cast

  6. Uses of plants, animal and mineral substances in Mediterranean ethno-veterinary practices for the care of small ruminants.

    Science.gov (United States)

    Piluzza, G; Virdis, S; Serralutzu, F; Bullitta, S

    2015-06-20

    The cultural heritage of Sardinian shepherds is rapidly vanishing and survives in the memory of elderly people. The objective of our study was not only to report the usage of plants and their preparation for administration but also the use of other remedies of different origin arising from traditional ethno-veterinary knowledge, as Sardinian shepherds were used to employ plants, animals, minerals and combinations of several substances to prepare remedies for prophylaxis or therapy on their animals. The work was carried out in rural areas of the island of Sardinia (Italy) by interviewing shepherds and filling questionnaires in order to record ethno-veterinary practices traditionally used for animal health care. Ethno-veterinary remedies traditionally utilised for treatments of small ruminants against ecto-and endo-parasites, gastrointestinal diseases, viral and bacterial diseases, wounds, sprains and bruises were identified. Non herbal remedies outnumbered the herbal ones, as usually plant species were mainly used for the care of cattle and equines. A total of 150 ethno-veterinary uses were documented for the treatment of 33 animal conditions, a detailed account of the formulations and their administration to sheep and goats was provided. Herbal remedies involved the use of twenty two spontaneous species and seven cultivated species. This study identifies remedies used in ethno-veterinary practices for small ruminants care in Sardinia, the second major Mediterranean island which has agro-pastoral activities dating back to Neolithic. Moreover, the danger of losing oral traditions, and the increasing attention towards traditional remedies as potential sources of natural products for improving animal health and welfare, support the interest of our survey. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  7. Imaging optimizations with non-pure and high-energy positron emitters in small animal positron computed tomography

    International Nuclear Information System (INIS)

    Harzmann, Sophie

    2014-01-01

    The contribution on imaging optimizations with non-pure and high-energy positron emitters in small animal positron emission tomography (PET) covers the following topics: physical fundamentals of PET, mathematical image reconstruction and data analyses, Monte-Carlo simulations and implemented correction scheme, quantification of cascade gamma coincidences based on simulations and measurements, sinogram based corrections, restoration of the spatial resolution, implementation of full corrections.

  8. Small mammals of the Mongolian mountain steppe region near Erdensant: insights from live-trapping and bird pellet remains.

    Directory of Open Access Journals (Sweden)

    Joanne L. Isaac

    2005-12-01

    Full Text Available Relatively little is known of the distribution, abundance and ecology of small mammals in Mongolia and as a result there is scant knowledge of the effects of environmental and anthropogenic factors on small mammal populations. The aim of this study was to assess the occurrence of small mammals in mountain steppe habitat from live-trapping and analysis of mammal remains from raptor pellets and below nests. During live-trapping, root voles ( Microtus oeconemus were the most commonly caught species accounting for 47.5 % of captures, striped hamsters ( Cricetulus barabensis and pika ( Ochotona hyperborea accounted for 30 % and 22.5 % of captures respectively. Temperature influenced trapping success, with small mammals appearing to avoid being active at temperatures over 20 ̊C. The three species caught on the trapping grid appeared to avoid competition for resources through both temporal and spatial differences in the use of available habitat. Mammals identified from raptor pellets and other remains included the grey hamster ( Cricatulus migratorius , Siberian marmot ( Marmota sibirica , red fox ( Vulpes vulpes , long-tailed souslik ( Citellus undulatus and the Daurian mole ( Myospalax aspalax. Results are discussed in terms of their relevance to the conservation of mammals in Mongolia and their co-existence with livestock and humans.

  9. 42 CFR 9.11 - Animal transport.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Animal transport. 9.11 Section 9.11 Public Health... CHIMPANZEES HELD IN THE FEDERALLY SUPPORTED SANCTUARY SYSTEM § 9.11 Animal transport. The transportation of... and Regulations and the International Air Transport Association (IATA) Live Animal Regulations and...

  10. A small animal PET prototype based on Silicon Photomultipliers

    International Nuclear Information System (INIS)

    Marcatili, S; Belcari, N.; Bisogni, M.G.; Del Guerra, A.; Collazuol, G.; Pedreschi, E.; Spinella, F.; Sportelli, G.; Marzocca, C.

    2011-01-01

    Next generation PET scanners should full fill very high requirements in terms of spatial, energy and timing resolution. Modern scanner performances are inherently limited by the use of standard photomultiplier tubes. The use of Silicon Photomultiplier (Si P M) matrices is proposed for the construction of a small animal PET system consisting of two detector heads based on Lyso continuos crystals. The use of large area multi-pixel Silicon Photomultiplier (Si P M) detectors requires the development of a multichannel Digital Acquisition system (DAQ) as well as of a dedicated front-end in order not to degrade the intrinsic detector capabilities. At the University of Pisa and INFN Pisa we developed a DAQ board for the read-out of 2 64-pixel Si P M matrices in time coincidence for Positron Emission Tomography (PET) applications. The proof of principles is based on 64-pixel detectors, but the whole system has been conceived to be easily scalable to a higher number of channels. Here we describe the Group-V INFN DASi P M 2 (Development and Application of Si P M) project and related results.

  11. Inhalation toxicology. I., Design of a small-animal test system, II. Determination of the relative toxic hazards of 75 aircraft cabin materials.

    Science.gov (United States)

    1977-01-01

    In an effort to further the cause of increased safety for those who ride in commercial aircraft, this paper presents a detailed description of the genesis of a small-scale, laboratory test system that utilizes small animals to evaluate the relative t...

  12. Microangiography in Living Mice Using Synchrotron Radiation

    International Nuclear Information System (INIS)

    Yuan Falei; Wang Yongting; Xie Bohua; Tang Yaohui; Guan Yongjing; Lu Haiyan; Yang Guoyuan; Xie Honglan; Du Guohao; Xiao Tiqiao

    2010-01-01

    Traditionally, there are no methods available to detect the fine morphologic changes of cerebrovasculature in small living animals such as rats and mice. Newly developed synchrotron radiation microangiography can achieve a fine resolution of several micrometers and had provided us with a powerful tool to study the cerebral vasculature in small animals. The purpose of this study is to identify the morphology of cerebrovasculature especially the structure of Lenticulostriate arteries (LSAs) in living mice using the synchrotron radiation source at Shanghai Synchrotron Radiation Facility (SSRF) in Shanghai, China. Adult CD-1 mice weighing 35-40 grams were anesthetized. Nonionic iodine (Omnipaque, 350 mg I /mL) was used as a contrast agent. The study was performed at the BL13W1 beam line at SSRF. The beam line was derived from a storage ring of electrons with an accelerated energy of 3.5 GeV and an average beam current of 200 mA. X-ray energy of 33.3 keV was used to produce the highest contrast image. Images were acquired every 172 ms by a x-ray camera (Photonic-Science VHR 1.38) with a resolution of 13 μm/pixel. The optimal dose of contrast agent is 100 μl per injection and the injecting rate is 33 μl/sec. The best position for imaging is to have the mouse lay on its right or left side, with ventral side facing the X-ray source. We observed the lenticulostriate artery for the first time in living mice. Our result show that there are 4 to 5 lenticulostriate branches originating from the root of middle cerebral artery in each hemisphere. LSAs have an average diameter of 43±6.8 μm. There were no differences between LSAs from the left and right hemisphere (p<0.05). These results suggest that synchrotron radiation may provide a unique tool for experimental stroke research.

  13. Microangiography in Living Mice Using Synchrotron Radiation

    Science.gov (United States)

    Yuan, Falei; Wang, Yongting; Guan, Yongjing; Lu, Haiyan; Xie, Bohua; Tang, Yaohui; Xie, Honglan; Du, Guohao; Xiao, Tiqiao; Yang, Guo-Yuan

    2010-07-01

    Traditionally, there are no methods available to detect the fine morphologic changes of cerebrovasculature in small living animals such as rats and mice. Newly developed synchrotron radiation microangiography can achieve a fine resolution of several micrometers and had provided us with a powerful tool to study the cerebral vasculature in small animals. The purpose of this study is to identify the morphology of cerebrovasculature especially the structure of Lenticulostriate arteries (LSAs) in living mice using the synchrotron radiation source at Shanghai Synchrotron Radiation Facility (SSRF) in Shanghai, China. Adult CD-1 mice weighing 35-40 grams were anesthetized. Nonionic iodine (Omnipaque, 350 mg I /mL) was used as a contrast agent. The study was performed at the BL13W1 beam line at SSRF. The beam line was derived from a storage ring of electrons with an accelerated energy of 3.5 GeV and an average beam current of 200 mA. X-ray energy of 33.3 keV was used to produce the highest contrast image. Images were acquired every 172 ms by a x-ray camera (Photonic-Science VHR 1.38) with a resolution of 13 μm/pixel. The optimal dose of contrast agent is 100 μl per injection and the injecting rate is 33 μl/sec. The best position for imaging is to have the mouse lay on its right or left side, with ventral side facing the X-ray source. We observed the lenticulostriate artery for the first time in living mice. Our result show that there are 4 to 5 lenticulostriate branches originating from the root of middle cerebral artery in each hemisphere. LSAs have an average diameter of 43±6.8 μm. There were no differences between LSAs from the left and right hemisphere (p<0.05). These results suggest that synchrotron radiation may provide a unique tool for experimental stroke research.

  14. 2D COSY sup 1 H NMR; A new tool for studying in sity brain metabolism in the living animal

    Energy Technology Data Exchange (ETDEWEB)

    Barrere, B.; Peres, M.; Seulaz, J. (Universite Paris 7 (France). Laboratoire de Physiologie et Physiopathologie Cerebrovasculaire INSERM U 182 CNRS UA 641, Paris (France)); Gillet, B.; Mergui, S.; Beloeil, J.-C. (Centre National de la Recherche Scientifique, 91 - Gif-sur-Yvette (France). Inst. de Chimie des Substances Naturelles)

    1990-05-21

    2D COSY {sup 1}H NMR with surface coil has been used to resolve and assign cerebral metabolites which had previously been detected but could not be resolved or assigned in situ in the living animal by conventional 1D {sup 1}H NMR. A wide range of cerebral metabolites, including alanine, N-acetyl asparate, asparate, choline derivatives, creatine/phosphocreatine pool, GABA, glucose, glutamate/glutamine pool, inositol, lactate and taurine were simultaneously resolved and assigned in situ in the whole animal using the 2D COSY correlation graphs. Global irreversible ischemia caused the appearance and the disappearance of cross-peaks in the 2D COSY {sup 1}H NMR map, corresponding to increases in alanine, GABA and lactate and glucose depletion. (author). 21 refs.; 3 figs.

  15. Intrathecal Catheterization and Drug Delivery in Guinea Pigs: A Small-animal Model for Morphine-evoked Granuloma Formation.

    Science.gov (United States)

    Eddinger, Kelly A; Rondon, Eric S; Shubayev, Veronica I; Grafe, Marjorie R; Scadeng, Miriam; Hildebrand, Keith R; Page, Linda M; Malkmus, Shelle A; Steinauer, Joanne J; Yaksh, Tony L

    2016-08-01

    Intrathecal infusion of opioids in dogs, sheep, and humans produces local space-occupying masses. To develop a small-animal model, the authors examined effects of intrathecal catheterization and morphine infusion in guinea pigs. Under isoflurane, polyethylene or polyurethane catheters were advanced from the cisterna magna to the lumbar enlargement. Drugs were delivered as a bolus through the externalized catheter or continuously by subcutaneous minipumps. Hind paw withdrawal to a thermal stimulus was assessed. Spinal histopathology was systematically assessed in a blinded fashion. To assist in determining catheter placement, ex vivo images were obtained using magnetic resonance imaging in several animals. Canine spinal tissue from previous intrathecal morphine studies was analyzed in parallel. (1) Polyethylene (n = 30) and polyurethane (n = 25) catheters were implanted in the lumbar intrathecal space. (2) Bolus intrathecal morphine produced a dose-dependent (20 to 40 μg/10 μl) increase in thermal escape latencies. (3) Absent infusion, a catheter-associated distortion of the spinal cord and a fibrotic investment were noted along the catheter tract (polyethylene > polyurethane). (4) Intrathecal morphine infusion (25 mg/ml/0.5 μl/h for 14 days) resulted in intrathecal masses (fibroblasts, interspersed collagen, lymphocytes, and macrophages) arising from meninges proximal to the catheter tip in both polyethylene- and polyurethane-catheterized animals. This closely resembles mass histopathology from intrathecal morphine canine studies. Continuous intrathecal infusion of morphine leads to pericatheter masses that morphologically resemble those observed in dogs and humans. This small-animal model may be useful for studying spinal drug toxicology in general and the biology of intrathecal granuloma formation in particular.

  16. Living in violence: Neighborhood domestic violence and small for gestational age births.

    Science.gov (United States)

    Felker-Kantor, Erica; Wallace, Maeve; Theall, Katherine

    2017-07-01

    To determine the association between neighborhood domestic violence and small-for-gestational-age (SGA) birth and to examine if there is a differential impact of neighborhood domestic violence on SGA births by race in a high crime community. This analysis includes all birth records issued in New Orleans, Louisiana from 2011 to 2012 geocoded by census tract (N=177 census tracts, N=8322 women). Hierarchical modeling and ecologic spatial analysis were used to examine the area-effect of neighborhood domestic violence on SGA births, independent of individual-level predictors and accounting for the propensity to live in high domestic violence neighborhoods. Tests for spatial autocorrelation reveled area-level clustering and overlap of SGA and domestic violent rates. Pregnant women living in high domestic violence areas were more likely to give birth to an SGA infant compared to women in low-domestic violence areas (OR=1.04, 95%CI: 1.01, 1.08), net of the effects of individual-level factors and propensity scores. Neighborhood-level attributes including rates of domestic violence may increase women's risk for SGA birth, highlighting a policy-relevant and potentially amenable exposure. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Noninvasive Assessment of Tumor Cell Proliferation in Animal Models

    Directory of Open Access Journals (Sweden)

    Matthias Edinger

    1999-10-01

    Full Text Available Revealing the mechanisms of neoplastic disease and enhancing our ability to intervene in these processes requires an increased understanding of cellular and molecular changes as they occur in intact living animal models. We have begun to address these needs by developing a method of labeling tumor cells through constitutive expression of an optical reporter gene, noninvasively monitoring cellular proliferation in vivo using a sensitive photon detection system. A stable line of HeLa cells that expressed a modified firefly luciferase gene was generated, proliferation of these cells in irradiated severe combined immunodeficiency (SCID mice was monitored. Tumor cells were introduced into animals via subcutaneous, intraperitoneal and intravenous inoculation and whole body images, that revealed tumor location and growth kinetics, were obtained. The number of photons that were emitted from the labeled tumor cells and transmitted through murine tissues was sufficient to detect 1×103 cells in the peritoneal cavity, 1×104 cells at subcutaneous sites and 1×106 circulating cells immediately following injection. The kinetics of cell proliferation, as measured by photon emission, was exponential in the peritoneal cavity and at subcutaneous sites. Intravenous inoculation resulted in detectable colonies of tumor cells in animals receiving more than 1×103 cells. Our demonstrated ability to detect small numbers of tumor cells in living animals noninvasively suggests that therapies designed to treat minimal disease states, as occur early in the disease course and after elimination of the tumor mass, may be monitored using this approach. Moreover, it may be possible to monitor micrometastases and evaluate the molecular steps in the metastatic process. Spatiotemporal analyses of neoplasia will improve the predictability of animal models of human disease as study groups can be followed over time, this method will accelerate development of novel therapeutic

  18. FDG small animal PET permits early detection of malignant cells in a xenograft murine model

    International Nuclear Information System (INIS)

    Nanni, Cristina; Spinelli, Antonello; Trespidi, Silvia; Ambrosini, Valentina; Castellucci, Paolo; Farsad, Mohsen; Franchi, Roberto; Fanti, Stefano; Leo, Korinne di; Tonelli, Roberto; Pession, Andrea; Pettinato, Cinzia; Rubello, Domenico

    2007-01-01

    The administration of new anticancer drugs in animal models is the first step from in vitro to in vivo pre-clinical protocols. At this stage it is crucial to ensure that cells are in the logarithmic phase of growth and to avoid vascular impairment, which can cause inhomogeneous distribution of the drug within the tumour and thus lead to bias in the final analysis of efficacy. In subcutaneous xenograft murine models, positivity for cancer is visually recognisable 2-3 weeks after inoculation, when a certain amount of necrosis is usually already present. The aim of this study was to evaluate the accuracy of FDG small animal PET for the early detection of malignant masses in a xenograft murine model of human rhabdomyosarcoma. A second goal was to analyse the metabolic behaviour of this xenograft tumour over time. We studied 23 nude mice, in which 7 x 10 6 rhabdomyosarcoma cells (RH-30 cell line) were injected in the dorsal subcutaneous tissues. Each animal underwent four FDG PET scans (GE, eXplore Vista DR) under gas anaesthesia. The animals were studied 2, 5, 14 and 20 days after inoculation. We administered 20 MBq of FDG via the tail vein. Uptake time was 60 min, and acquisition time, 20 min. Images were reconstructed with OSEM 2D iterative reconstruction and the target to background ratio (TBR) was calculated for each tumour. Normal subcutaneous tissue had a TBR of 0.3. Necrosis was diagnosed when one or more cold areas were present within the mass. All the animals were sacrificed and histology was available to verify PET results. PET results were concordant with the findings of necropsy and histology in all cases. The incidence of the tumour was 69.6% (16/23 animals); seven animals did not develop a malignant mass. Ten of the 23 animals had a positive PET scan 2 days after inoculation. Nine of these ten animals developed a tumour; the remaining animal became negative, at the third scan. The positive predictive value of the early PET scan was 90% (9/10 animals

  19. 9 CFR 113.64 - General requirements for live bacterial vaccines.

    Science.gov (United States)

    2010-01-01

    ... bacterial vaccines. 113.64 Section 113.64 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION... STANDARD REQUIREMENTS Live Bacterial Vaccines § 113.64 General requirements for live bacterial vaccines... bacterial vaccine shall meet the requirements in this section. (a) Purity test. Final container samples of...

  20. Scanning multiple mice in a small-animal PET scanner: Influence on image quality

    International Nuclear Information System (INIS)

    Siepel, Francoise J.; Lier, Monique G.J.T.B. van; Chen Mu; Disselhorst, Jonathan A.; Meeuwis, Antoi P.W.; Oyen, Wim J.G.; Boerman, Otto C.; Visser, Eric P.

    2010-01-01

    To achieve high throughput in small-animal positron emission tomography (PET), it may be advantageous to scan more than one animal in the scanner's field of view (FOV) at the same time. However, due to the additional activity and increase of Poisson noise, additional attenuating mass, extra photon scattering, and radial or axial displacement of the animals, a deterioration of image quality can be expected. In this study, the NEMA NU 4-2008 image quality (NU4IQ) phantom and up to three FDG-filled cylindrical 'mouse phantoms' were positioned in the FOV of the Siemens Inveon small-animal PET scanner to simulate scans with multiple mice. Five geometrical configurations were examined. In one configuration, the NU4IQ phantom was scanned separately and placed in the center of the FOV (1C). In two configurations, a mouse phantom was added with both phantoms displaced radially (2R) or axially (2A). In two other configurations, the NU4IQ phantom was scanned along with three mouse phantoms with all phantoms displaced radially (4R), or in a combination of radial and axial displacement (2R2A). Images were reconstructed using ordered subset expectation maximization in 2 dimensions (OSEM2D) and maximum a posteriori (MAP) reconstruction. Image quality parameters were obtained according to the NEMA NU 4-2008 guidelines. Optimum image quality was obtained for the 1C geometry. Image noise increased by the addition of phantoms and was the largest for the 4R configuration. Spatial resolution, reflected in the recovery coefficients for the FDG-filled rods, deteriorated by radial displacement of the NU4IQ phantom (2R, 2R2A, and 4R), most strongly for OSEM2D, and to a smaller extent for MAP reconstructions. Photon scatter, as indicated by the spill-over ratios in the non-radioactive water- and air-filled compartments, increased by the addition of phantoms, most strongly for the 4R configuration. Application of scatter correction substantially lowered the spill-over ratios, but caused an

  1. Evaluation of the economic and clinical feasibility of introducing rigid endoscopy and laparoscopy to a small animal general practice.

    Science.gov (United States)

    Jones, Kelly; Case, J Brad; Evans, Brian; Monnet, Eric

    2017-04-01

    OBJECTIVE To evaluate the economic and clinical feasibility of introducing rigid endoscopy and laparoscopy to a small animal general practice. DESIGN Prospective study. SAMPLE A single 2-veterinarian small animal practice in southern California. PROCEDURES In early 2012, endoscopic equipment was purchased, and both veterinarians in the practice undertook training in rigid endoscopic and laparoscopic procedures. Subsequently, information for client-owned animals that underwent endoscopic and laparoscopic procedures during a 12-month period (2012 to 2013) was collected. Cost of equipment and training, revenue generated, specific procedures performed, surgery time, complications, and client satisfaction were evaluated. RESULTS 78 endoscopic procedures were performed in 73 patients, including 71 dogs, 1 cat, and 1 rabbit. Cost of endoscopic and laparoscopic equipment and training in the first year was $14,809.71; most equipment was financed through a 5-year lease at a total cost of $57,507.70 ($ 10,675.20/y). Total revenue generated in the first year was $50,423.63. The most common procedures performed were ovariectomy (OVE; n = 49), prophylactic gastropexy (6), and video otoscopy (12). Mean ± SD surgery times for OVE (n = 44) and for OVE with gastropexy (5) were 63.7 ± 19.7 minutes and 73.0 ± 33.5 minutes; respectively. Twelve of 54 patients undergoing laparoscopic procedures experienced minor intraoperative complications. Conversion to laparotomy was not required in any patient. There were no major complications. All 49 clients available for follow-up were satisfied. CONCLUSIONS AND CLINICAL RELEVANCE With appropriate training and equipment, incorporation of basic rigid endoscopy and laparoscopy may be feasible in small animal general practice. However, results of the present study are not applicable to all veterinarians and practice settings, and patient safety considerations should always be paramount.

  2. Animal Welfare: Freedoms, Dominions and "A Life Worth Living".

    Science.gov (United States)

    Webster, John

    2016-05-24

    This opinion paper considers the relative validity and utility of three concepts: the Five Freedoms (FF), Five Domains (FD) and Quality of Life (QoL) as tools for the analysis of animal welfare. The aims of FF and FD are different but complementary. FD seeks to assess the impact of the physical and social environment on the mental (affective) state of a sentient animal, FF is an outcome-based approach to identify and evaluate the efficacy of specific actions necessary to promote well-being. Both have utility. The concept of QoL is presented mainly as a motivational framework. The FD approach provides an effective foundation for research and evidence-based conclusions as to the impact of the things we do on the mental state of the animals in our care. Moreover, it is one that can evolve with time. The FF are much simpler. They do not attempt to achieve an overall picture of mental state and welfare status, but the principles upon which they are based are timeless. Their aim is to be no more than a memorable set of signposts to right action. Since, so far as the animals are concerned, it is not what we think but what we do that counts, I suggest that they are likely to have a more general impact.

  3. Fluorosis in humans and animals

    Directory of Open Access Journals (Sweden)

    Mirona Palczewska-Komsa

    2015-12-01

    Full Text Available Fluorine compounds occur quite commonly in nature. They are exist in water, in soil, in geological decks, in living organisms. On human and animal bodies can influence moderately preferably or more often unfavorably. The deficiency or excess of this element results in undesirable effects in hard tissue, nervous tissue and other organs. Due to adverse effect of this element to a living organism it comes to fluorosis. The aim of the study was to determine the influence of the toxic effect of fluoride compounds on the human and other vertebrate animals depending on the time and dosage F- and the type of tissue and / or organ on the basis of the scientific literature. On the basis of the available publications, it was revealed that F- toxicity substantially depends on time and dose exposure on these element. Chronic fluorosis, more often than acute is observed in human and animals. Biological factors (including species differences susceptibility, metabolic activity of tissue and environmental factors can accumulate, which increases probability of F- toxicity for living organisms.

  4. 36 CFR 10.1 - Animals available.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 1 2010-07-01 2010-07-01 false Animals available. 10.1 Section 10.1 Parks, Forests, and Public Property NATIONAL PARK SERVICE, DEPARTMENT OF THE INTERIOR DISPOSAL OF CERTAIN WILD ANIMALS § 10.1 Animals available. From time to time there are surplus live elk...

  5. Increased concentration of Pseudomonas aeruginosa and Staphylococcus sp. in small animals exposed to aerospace environments

    Science.gov (United States)

    Guthrie, R. K.

    1976-01-01

    The effects of increased concentrations of PSEUDOMONAS AERUGINOSA AND STAPHYLOCOCCUS in the total bacterial flora of small animals exposed to simulated spacecraft environments were evaluated. Tests to detect changes in infectivity, effects of antibiotic treatments, immune responses to bacterial antigens, and effectiveness of immune responses in the experimental environment were conducted. The most significant results appear to be the differences in immune responses at simulated altitudes and the production of infection in the presence of a specific antibody.

  6. Animation & Neurocinematics*

    DEFF Research Database (Denmark)

    Carpe Pérez, Inmaculada Concepción

    2015-01-01

    , indeed, can be considered a social/ emotional learning media, which goes beyond the limitations of live action movies. This is due to the diversity of techniques, and its visual plasticity that constructs the impossible. Animators are not real actors but more like the midwife who brings the anima...... into aliveness, which requires knowing how emotions work. Ed Hooks as an expert in training animators and actors, always remarks: “emotions tend to lead to action”. In this paper we want to argue that by producing animated films, as we watch them, cause a stronger effect, not only in our brains, but also in our...... bodies. By using animation as a learning tool we can explore the world of emotions and question beliefs, feelings and actions in order to express our voices and enhance our communication, and well-being, both, internally and with others. Animation can be the visual expression of the emotions in movement...

  7. Vermicomposting as manure management strategy for urban small-holder animal farms – Kampala case study

    International Nuclear Information System (INIS)

    Lalander, Cecilia Helena; Komakech, Allan John; Vinnerås, Björn

    2015-01-01

    Highlights: • Poor manure management can increase burden of disease and environmental impact. • A low-maintenance vermicompost reactor was set-up in Kampala, Uganda. • High material reduction (45.9%) and waste-to-biomass conversion (3.6% on a TS basis). • Five year return on investment of 275% of system in Uganda. • Technically and economically viable system for improved urban manure management. - Abstract: Inadequate organic waste management can contribute to the spread of diseases and have negative impacts on the environment. Vermicomposting organic waste could have dual beneficial effects by generating an economically viable animal feed protein in the form of worm biomass, while alleviating the negative effects of poor organic waste management. In this study, a low-maintenance vermicomposting system was evaluated as manure and food waste management system for small-holder farmers. A vermicomposting system using the earthworm species Eudrilus eugeniae and treating cow manure and food waste was set up in Kampala, Uganda, and monitored for 172 days. The material degradation and protein production rates were evaluated after 63 days and at the end of the experiment. The material reduction was 45.9% and the waste-to-biomass conversion rate was 3.5% in the vermicomposting process on a total solids basis. A possible increase in the conversion rate could be achieved by increasing the frequency of worm harvesting. Vermicomposting was found to be a viable manure management method in small-scale urban animal agriculture; the return of investment was calculated to be 280% for treating the manure of a 450 kg cow. The vermicompost was not sanitised, although hygiene quality could be improved by introducing a post-stabilisation step in which no fresh material is added. The value of the animal feed protein generated in the process can act as an incentive to improve current manure management strategies

  8. Dynamic {sup 18}F-fluoride small animal PET to noninvasively assess renal function in rats

    Energy Technology Data Exchange (ETDEWEB)

    Schnoeckel, Uta; Stegger, Lars; Schaefers, Klaus P.; Hermann, Sven; Schober, Otmar; Schaefers, Michael [Klinik und Poliklinik fuer Nuklearmedizin, Muenster (Germany); Reuter, Stefan; Schlatter, Eberhard; Gabriels, Gert [Universitaetsklinikum Muenster, Medizinische Klinik und Poliklinik D, Experimentelle Nephrologie, Muenster (Germany)

    2008-12-15

    Renal function can be quantified by both laboratory and scintigraphic methods. In the case of small animal diagnostics, scintigraphic image-based methods are ideal since they can assess split renal function, work noninvasively, and can be repeated. The aim of this study is to validate a {sup 18}F-PET-based method to quantify renal function in rats. Fluoride clearance was calculated from a dynamic whole body listmode acquisition of 60 min length in a small animal PET scanner following an i.v. injection of 15 MBq {sup 18}F-fluoride. Volumes of interest (VOIs) were placed in the left ventricle and the bladder as well as traced around the kidney contours. The respective time-activity curves (TAC) were calculated. The renal {sup 18}F-clearance was calculated by the ratio of the total renal excreted activity (bladder VOI) and the integral of the blood TAC. PET-derived renal function was validated by intraindividual measurements of creatinine clearance (n=23), urea clearance (n=23), and tubular excretion rate (TER-MAG3). The split renal function was derived from the injection of the clinically available radionuclide {sup 99m}Tc-mercaptotriglycine by blood sampling and planar renography (n=8). In all animals studied, PET revealed high-quality TACs. PET-derived renal fluoride clearance was linearly correlated with intraindividual laboratory measures (PET vs. creatinine: r=0.78; PET vs. urea: r=0.73; PET vs. TER-MAG3: r=0.73). Split function was comparable ({sup 18}F-PET vs. MAG3-renography: r=0.98). PET-derived measures were highly reproducible. {sup 18}F-PET is able to noninvasively assess renal function in rats and provides a significant potential for serial studies in different experimental scenarios. (orig.)

  9. Vermicomposting as manure management strategy for urban small-holder animal farms – Kampala case study

    Energy Technology Data Exchange (ETDEWEB)

    Lalander, Cecilia Helena, E-mail: cecilia.lalander@slu.se [Department of Energy and Technology, Swedish University of Agricultural Sciences, Uppsala (Sweden); Komakech, Allan John [Department of Energy and Technology, Swedish University of Agricultural Sciences, Uppsala (Sweden); Department of Agricultural & Bio-systems Engineering, Makerere University, Kampala (Uganda); Vinnerås, Björn [Department of Energy and Technology, Swedish University of Agricultural Sciences, Uppsala (Sweden)

    2015-05-15

    Highlights: • Poor manure management can increase burden of disease and environmental impact. • A low-maintenance vermicompost reactor was set-up in Kampala, Uganda. • High material reduction (45.9%) and waste-to-biomass conversion (3.6% on a TS basis). • Five year return on investment of 275% of system in Uganda. • Technically and economically viable system for improved urban manure management. - Abstract: Inadequate organic waste management can contribute to the spread of diseases and have negative impacts on the environment. Vermicomposting organic waste could have dual beneficial effects by generating an economically viable animal feed protein in the form of worm biomass, while alleviating the negative effects of poor organic waste management. In this study, a low-maintenance vermicomposting system was evaluated as manure and food waste management system for small-holder farmers. A vermicomposting system using the earthworm species Eudrilus eugeniae and treating cow manure and food waste was set up in Kampala, Uganda, and monitored for 172 days. The material degradation and protein production rates were evaluated after 63 days and at the end of the experiment. The material reduction was 45.9% and the waste-to-biomass conversion rate was 3.5% in the vermicomposting process on a total solids basis. A possible increase in the conversion rate could be achieved by increasing the frequency of worm harvesting. Vermicomposting was found to be a viable manure management method in small-scale urban animal agriculture; the return of investment was calculated to be 280% for treating the manure of a 450 kg cow. The vermicompost was not sanitised, although hygiene quality could be improved by introducing a post-stabilisation step in which no fresh material is added. The value of the animal feed protein generated in the process can act as an incentive to improve current manure management strategies.

  10. Assessing Glomerular Filtration in Small Animals Using [68Ga]DTPA and [68Ga]EDTA with PET Imaging.

    Science.gov (United States)

    Gündel, Daniel; Pohle, Ulrike; Prell, Erik; Odparlik, Andreas; Thews, Oliver

    2018-06-01

    Determining the glomerular filtration rate (GFR) is essential for clinical medicine but also for pre-clinical animal studies. Functional imaging using positron emission tomography (PET) allows repetitive almost non-invasive measurements. The aim of the study was the development and evaluation of easily synthesizable PET tracers for GFR measurements in small animals. Diethylenetriaminepentaacetic acid (DTPA) and ethylenediaminetetraacetic acid (EDTA) were labeled with Ga-68. The binding to blood cells and plasma proteins was tested in vitro. The distribution of the tracers in rats was analyzed by PET imaging and ex vivo measurements. From the time-activity-curve of the blood compartment (heart) and the total tracer mass excreted by the kidney, the GFR was calculated. These values were compared directly with the inulin clearance in the same animals. Both tracers did not bind to blood cells. [ 68 Ga]DPTA but not [ 68 Ga]EDTA showed strong binding to plasma proteins. For this reason, [ 68 Ga]DPTA stayed much longer in the blood and only 30 % of the injected dose was eliminated by the kidney within 60 min whereas the excretion of [ 68 Ga]EDTA was 89 ± 1 %. The calculated GFR using [ 68 Ga]EDTA was comparable to the measured inulin clearance in the same animal. Using [ 68 Ga]-DPTA, the measurements led to values which were 80 % below the normal GFR. The results also revealed that definition of the volume of interest for the blood compartment affects the calculation and may lead to a slight overestimation of the GFR. [ 68 Ga]EDTA is a suitable tracer for GFR calculation from PET imaging in small animals. It is easy to be labeled, and the results are in good accordance with the inulin clearance. [ 68 Ga]DTPA led to a marked underestimation of GFR due to its strong binding to plasma proteins and is therefore not an appropriate tracer for GFR measurements.

  11. Professor: The Animal Planet Optimization

    OpenAIRE

    Satish Gajawada

    2014-01-01

    This paper is dedicated to everyone who is interested in making this planet a better place to live. In the past, researchers have explored behavior of several animals separately. But there is scope to explore in the direction where various artificial animals together solve the optimization problem. In this paper, Satish Gajawada proposed The AnimalPlanet Optimization. The concept of this paper is to imitate all the animals on this planet. The idea is to solve the optimization problem where al...

  12. Performance characterization of the Inveon preclinical small-animal PET/SPECT/CT system for multimodality imaging

    International Nuclear Information System (INIS)

    Magota, Keiichi; Kubo, Naoki; Kuge, Yuji; Nishijima, Ken-ichi; Zhao, Songji; Tamaki, Nagara

    2011-01-01

    We investigated the performance of the Inveon small-animal PET/SPECT/CT system and compared the imaging capabilities of the SPECT and PET components. For SPECT, the energy resolution, tomographic spatial resolution and system sensitivity were evaluated with a 99m Tc solution using a single pinhole collimator. For PET, the spatial resolution, absolute sensitivity, scatter fraction and peak noise equivalent count were evaluated. Phantoms and a normal rat were scanned to compare the imaging capabilities of SPECT and PET. The SPECT spatial resolution was 0.84 mm full-width at half-maximum (FWHM) at a radius of rotation of 25 mm using a 0.5-mm pinhole aperture collimator, while the PET spatial resolution was 1.63 mm FWHM at the centre. The SPECT system sensitivity at a radius of rotation of 25 mm was 35.3 cps/MBq (4 x 10 -3 %) using the 0.5-mm pinhole aperture, while the PET absolute sensitivity was 3.2% for 350-650 keV and 3.432 ns. Accordingly, the volume sensitivity of PET was three orders of magnitude higher than that of SPECT. This integrated PET/SPECT/CT system showed high performance with excellent spatial resolution for SPECT and sensitivity for PET. Based on the tracer availability and system performance, SPECT and PET have complementary roles in multimodality small-animal imaging. (orig.)

  13. Monitor hemoglobin concentration and oxygen saturation in living mouse tail using photoacoustic CT scanner

    Science.gov (United States)

    Liu, Bo; Kruger, Robert; Reinecke, Daniel; Stantz, Keith M.

    2010-02-01

    Purpose: The purpose of this study is to use PCT spectroscopy scanner to monitor the hemoglobin concentration and oxygen saturation change of living mouse by imaging the artery and veins in a mouse tail. Materials and Methods: One mouse tail was scanned using the PCT small animal scanner at the isosbestic wavelength (796nm) to obtain its hemoglobin concentration. Immediately after the scan, the mouse was euthanized and its blood was extracted from the heart. The true hemoglobin concentration was measured using a co-oximeter. Reconstruction correction algorithm to compensate the acoustic signal loss due to the existence of bone structure in the mouse tail was developed. After the correction, the hemoglobin concentration was calculated from the PCT images and compared with co-oximeter result. Next, one mouse were immobilized in the PCT scanner. Gas with different concentrations of oxygen was given to mouse to change the oxygen saturation. PCT tail vessel spectroscopy scans were performed 15 minutes after the introduction of gas. The oxygen saturation values were then calculated to monitor the oxygen saturation change of mouse. Results: The systematic error for hemoglobin concentration measurement was less than 5% based on preliminary analysis. Same correction technique was used for oxygen saturation calculation. After correction, the oxygen saturation level change matches the oxygen volume ratio change of the introduced gas. Conclusion: This living mouse tail experiment has shown that NIR PCT-spectroscopy can be used to monitor the oxygen saturation status in living small animals.

  14. Sub-millimetre DOI detector based on monolithic LYSO and digital SiPM for a dedicated small-animal PET system

    International Nuclear Information System (INIS)

    Marcinkowski, Radosław; Mollet, Pieter; Van Holen, Roel; Vandenberghe, Stefaan

    2016-01-01

    The mouse model is widely used in a vast range of biomedical and preclinical studies. Thanks to the ability to detect and quantify biological processes at the molecular level in vivo, PET has become a well-established tool in these investigations. However, the need to visualize and quantify radiopharmaceuticals in anatomic structures of millimetre or less requires good spatial resolution and sensitivity from small-animal PET imaging systems. In previous work we have presented a proof-of-concept of a dedicated high-resolution small-animal PET scanner based on thin monolithic scintillator crystals and Digital Photon Counter photosensor. The combination of thin monolithic crystals and MLE positioning algorithm resulted in an excellent spatial resolution of 0.7 mm uniform in the entire field of view (FOV). However, the limitation of the scanner was its low sensitivity due to small thickness of the lutetium-yttrium oxyorthosilicate (LYSO) crystals (2 mm). Here we present an improved detector design for a small-animal PET system that simultaneously achieves higher sensitivity and sustains a sub-millimetre spatial resolution. The proposed detector consists of a 5 mm thick monolithic LYSO crystal optically coupled to a Digital Photon Counter. Mean nearest neighbour (MNN) positioning combined with depth of interaction (DOI) decoding was employed to achieve sub-millimetre spatial resolution. To evaluate detector performance the intrinsic spatial resolution, energy resolution and coincidence resolving time (CRT) were measured. The average intrinsic spatial resolution of the detector was 0.60 mm full-width-at-half-maximum (FWHM). A DOI resolution of 1.66 mm was achieved. The energy resolution was 23% FWHM at 511 keV and CRT of 529 ps were measured. The improved detector design overcomes the sensitivity limitation of the previous design by increasing the nominal sensitivity of the detector block and retains an excellent intrinsic spatial resolution. (paper)

  15. Thermodynamic Limits of Body Dimension of Warm Blooded Animals

    Science.gov (United States)

    Ahlborn, Boye K.

    2000-05-01

    The metabolic rates Г o = aoM 0.73 [W], a 0 = 3.6, of animals of different body masses M [kg] determines their heat production Q' and their mechanical power output P. The metabolic heat production of small warm blooded animals living in a cold environment sets lower size limits for the body mass of birds and terrestrial mammals of Mt,b ≥ 0.01 kg and Maq ≥ 10 kg for fast aquatic mammals. Birds must travel at the speed υfl = 15M 1/6 [m/s] in order to stay aloft, but their muscles only generate the metabolic velocity υ Г ≤≈ 50M -0.25 [m/s]. These conditions yield an upper body size limit for flying birds: Mb ,max ≤ 15 kg. Walking speeds scale with body mass as υ walk ∝ M 1/6, while propagation speeds for endurance running are nearly independent of body mass. This makes walking faster than endurance running for animals with body masses M ≥ 600 kg.

  16. Development of Input Function Measurement System for Small Animal PET Study

    International Nuclear Information System (INIS)

    Kim, Jong Guk; Kim, Byung Su; Kim, Jin Su

    2010-01-01

    For quantitative measurement of radioactivity concentration in tissue and a validated tracer kinetic model, the high sensitive detection system has been required for blood sampling. With the accurate measurement of time activity curves (TACs) of labeled compounds in blood (plasma) enable to provide quantitative information on biological parameters of interest in local tissue. Especially, the development of new tracers for PET imaging requires knowledge of the kinetics of the tracer in the body and in arterial blood and plasma. Conventional approaches of obtaining an input function are to sample arterial blood sequentially by manual as a function of time. Several continuous blood sampling systems have been developed and used in nuclear medicine research field to overcome the limited temporal resolution in sampling by the conventional method. In this work, we developed the high sensitive and unique geometric design of GSO detector for small animal blood activity measurement

  17. Coil concepts for rapid and motion-compensated MR-Imaging of small animals; Spulenkonzepte zur schnellen und bewegungskompensierten MR-Bildgebung von Kleintieren

    Energy Technology Data Exchange (ETDEWEB)

    Korn, Matthias

    2009-05-06

    In this work radiofrequency-coils for the imaging of small animals in clinical whole-body MRI-systems were developed. Therefore in a first step single-channel solenoids were designed and characterized. The solenoids had two and three windings respectively, which were implemented as double wires to increase the homogeneity of the receive profile. These coils allow the acquisition of whole-body images of mice with high signal-to-noise ratio and homogeneity over a distance of at least 6.3 cm. Since many imaging experiments require rapid image acquisition, in the next step a novel coil concept was developed, which, due to its geometry, enables parallel imaging in arbitrary directions. A prototype was assembled and tested on phantom and small-animal experiments. With an accelerating factor of R=2, the difference of the SNR in all directions from the theoretical maximum, was less than 1%. In order to compensate physiological motion by the self-gating technique, in this work a coil is presented for the first time, which selectively amplifies the self-gating signal, while - due to a optical detuning technique - preserving the homogeneous illumination of the image. In vivo experiments on a small animal show an amplification of the self-gating signal by at least 40%. (orig.)

  18. Microbiological Standardization in Small Laboratory Animals and Recommendations for the Monitoring

    Directory of Open Access Journals (Sweden)

    Meral Karaman

    2014-03-01

    Full Text Available Microbiological standardization in laboratory animal breeding is based on the classification according to the microorganisms that the animals host and consequently their upbringing environment, as well as the certification of their microbiological status and the protection of their properties. Although there are many different classifications for microbiological standardization of laboratory animals, they can be basically classified as; gnotobiotic animals, animals bred with a complete barrier system (Germ free, GF, with Colonization-Resistant Flora; CRF, animals bred with a partial barrier system (Specified Pathogen Free, SPF, and animals bred by conventional methods in units without barriers (Conventional; CV. Monitoring of microbiological standardization is carried out in two ways. One is controlling barrier systems (process control and the other is controlling laboratory animals (product control. In controlling barrier systems samples are taken routinely from ambient air, surfaces, base plate materials of animals, foods and waters, and microbiological tests are carried out. FELASA guidelines are frequently used in monitoring laboratory animals. These guidelines where the monitoring frequency, sample size, micro-organisms to be tested, vary according to the microbiological quality of the animals, and test methods and are frequently updated by FELASA and shared in their web pages. In our country, in general, laboratory animals used for experimental studies present no microbiological standardization, and follow-up protocols are not implemented. Therefore, construction of facilities for the production of microbiologically standard animals and establishment of backup laboratories testing microbiological quality should be established.

  19. Optimization and performance evaluation of the microPET II scanner for in vivo small-animal imaging

    International Nuclear Information System (INIS)

    Yang Yongfeng; Tai Yuanchuan; Siegel, Stefan; Newport, Danny F; Bai, Bing; Li, Quanzheng; Leahy, Richard M; Cherry, Simon R

    2004-01-01

    MicroPET II is a newly developed PET (positron emission tomography) scanner designed for high-resolution imaging of small animals. It consists of 17 640 LSO crystals each measuring 0.975 x 0.975 x 12.5 mm 3 , which are arranged in 42 contiguous rings, with 420 crystals per ring. The scanner has an axial field of view (FOV) of 4.9 cm and a transaxial FOV of 8.5 cm. The purpose of this study was to carefully evaluate the performance of the system and to optimize settings for in vivo mouse and rat imaging studies. The volumetric image resolution was found to depend strongly on the reconstruction algorithm employed and averaged 1.1 mm (1.4 μl) across the central 3 cm of the transaxial FOV when using a statistical reconstruction algorithm with accurate system modelling. The sensitivity, scatter fraction and noise-equivalent count (NEC) rate for mouse- and rat-sized phantoms were measured for different energy and timing windows. Mouse imaging was optimized with a wide open energy window (150-750 keV) and a 10 ns timing window, leading to a sensitivity of 3.3% at the centre of the FOV and a peak NEC rate of 235 000 cps for a total activity of 80 MBq (2.2 mCi) in the phantom. Rat imaging, due to the higher scatter fraction, and the activity that lies outside of the field of view, achieved a maximum NEC rate of 24 600 cps for a total activity of 80 MBq (2.2 mCi) in the phantom, with an energy window of 250-750 keV and a 6 ns timing window. The sensitivity at the centre of the FOV for these settings is 2.1%. This work demonstrates that different scanner settings are necessary to optimize the NEC count rate for different-sized animals and different injected doses. Finally, phantom and in vivo animal studies are presented to demonstrate the capabilities of microPET II for small-animal imaging studies

  20. Chemotherapy drug handling in first opinion small animal veterinary practices in the United Kingdom: results of a questionnaire survey.

    Science.gov (United States)

    Edery, E G

    2017-05-27

    To investigate how first opinion small animal veterinary surgeons in the UK handled chemotherapeutic agents, a questionnaire was distributed at the 2014 British Small Animal Veterinary Association congress and by internet. Chemotherapy was regularly offered by 70.4 per cent of the respondents. Gold standards defined according to available guidelines for safe handling of antineoplastic drugs were poorly followed by general practitioners with only 2 per cent of respondents complying with all of them. Dedicated facilities for preparation and administration of cytotoxic drugs were variably available among participants. The level of training of staff indirectly involved in handling chemotherapy was appropriate in less than 50 per cent of practices. No association was found between demographic characteristics of the sampled population and the decision to perform chemotherapy. The results of this study raise concerns about the safety of the veterinary staff in first opinion practices involved in handling chemotherapy. British Veterinary Association.

  1. Use of aspiration method for collecting brain samples for rabies diagnosis in small wild animals.

    Science.gov (United States)

    Iamamoto, K; Quadros, J; Queiroz, L H

    2011-02-01

    In developing countries such as Brazil, where canine rabies is still a considerable problem, samples from wildlife species are infrequently collected and submitted for screening for rabies. A collaborative study was established involving environmental biologists and veterinarians for rabies epidemiological research in a specific ecological area located at the Sao Paulo State, Brazil. The wild animals' brains are required to be collected without skull damage because the skull's measurements are important in the identification of the captured animal species. For this purpose, samples from bats and small mammals were collected using an aspiration method by inserting a plastic pipette into the brain through the magnum foramen. While there is a progressive increase in the use of the plastic pipette technique in various studies undertaken, it is also appreciated that this method could foster collaborative research between wildlife scientists and rabies epidemiologists thus improving rabies surveillance. © 2009 Blackwell Verlag GmbH.

  2. Cell and small animal models for phenotypic drug discovery

    Directory of Open Access Journals (Sweden)

    Szabo M

    2017-06-01

    Full Text Available Mihaly Szabo,1 Sara Svensson Akusjärvi,1 Ankur Saxena,1 Jianping Liu,2 Gayathri Chandrasekar,1 Satish S Kitambi1 1Department of Microbiology Tumor, and Cell Biology, 2Department of Biochemistry and Biophysics, Karolinska Institutet, Solna, Sweden Abstract: The phenotype-based drug discovery (PDD approach is re-emerging as an alternative platform for drug discovery. This review provides an overview of the various model systems and technical advances in imaging and image analyses that strengthen the PDD platform. In PDD screens, compounds of therapeutic value are identified based on the phenotypic perturbations produced irrespective of target(s or mechanism of action. In this article, examples of phenotypic changes that can be detected and quantified with relative ease in a cell-based setup are discussed. In addition, a higher order of PDD screening setup using small animal models is also explored. As PDD screens integrate physiology and multiple signaling mechanisms during the screening process, the identified hits have higher biomedical applicability. Taken together, this review highlights the advantages gained by adopting a PDD approach in drug discovery. Such a PDD platform can complement target-based systems that are currently in practice to accelerate drug discovery. Keywords: phenotype, screening, PDD, discovery, zebrafish, drug

  3. Implementation of Cascade Gamma and Positron Range Corrections for I-124 Small Animal PET

    Science.gov (United States)

    Harzmann, S.; Braun, F.; Zakhnini, A.; Weber, W. A.; Pietrzyk, U.; Mix, M.

    2014-02-01

    Small animal Positron Emission Tomography (PET) should provide accurate quantification of regional radiotracer concentrations and high spatial resolution. This is challenging for non-pure positron emitters with high positron endpoint energies, such as I-124: On the one hand the cascade gammas emitted from this isotope can produce coincidence events with the 511 keV annihilation photons leading to quantification errors. On the other hand the long range of the high energy positron degrades spatial resolution. This paper presents the implementation of a comprehensive correction technique for both of these effects. The established corrections include a modified sinogram-based tail-fitting approach to correct for scatter, random and cascade gamma coincidences and a compensation for resolution degradation effects during the image reconstruction. Resolution losses were compensated for by an iterative algorithm which incorporates a convolution kernel derived from line source measurements for the microPET Focus 120 system. The entire processing chain for these corrections was implemented, whereas previous work has only addressed parts of this process. Monte Carlo simulations with GATE and measurements of mice with the microPET Focus 120 show that the proposed method reduces absolute quantification errors on average to 2.6% compared to 15.6% for the ordinary Maximum Likelihood Expectation Maximization algorithm. Furthermore resolution was improved in the order of 11-29% depending on the number of convolution iterations. In summary, a comprehensive, fast and robust algorithm for the correction of small animal PET studies with I-124 was developed which improves quantitative accuracy and spatial resolution.

  4. Intravital Microscopy Reveals Differences in the Kinetics of Endocytic Pathways between Cell Cultures and Live Animals

    Directory of Open Access Journals (Sweden)

    Roberto Weigert

    2012-11-01

    Full Text Available Intravital microscopy has enabled imaging of the dynamics of subcellular structures in live animals, thus opening the door to investigating membrane trafficking under physiological conditions. Here, we sought to determine whether the architecture and the environment of a fully developed tissue influences the dynamics of endocytic processes. To this aim, we imaged endocytosis in the stromal cells of rat salivary glands both in situ and after they were isolated and cultured on a solid surface. We found that the internalization of transferrin and dextran, two molecules that traffic via distinct mechanisms, is substantially altered in cultured cells, supporting the idea that the three dimensional organization of the tissue and the cues generated by the surrounding environment strongly affect membrane trafficking events.

  5. Measuring acute changes in adrenergic nerve activity of the heart in the living animal

    International Nuclear Information System (INIS)

    Sisson, J.C.; Bolgos, G.; Johnson, J.

    1991-01-01

    Changes in the function of the adrenergic neurons of the heart may be important indicators of the adaptations of an animal to physiologic stress and disease. Rates of loss of norepinephrine (NE) from the heart were considered to be proportional to NE secretion and to adrenergic function. In rat hearts, yohimbine induced almost identical increases in rates of loss of 3 H-NE and of 125 I-metaiodobenzylguanidine (MIBG), a functional analog of NE. Clonidine induced decreases in rates of loss of 3 H-NE that were also mimicked by those of 125 I-MIBG. In the dog heart, pharmacologically-induced increases and decreases in rates of loss of 123 I-MIBG could be measured externally; these values were similar to those obtained for 125 I-MIBG in the rat heart. Thus acute changes in the adrenergic neuron activity can be measured in the living heart. The method is applicable to man in determining the capacity of the adrenergic system to respond to provocative challenges

  6. Small animal SPECT and its place in the matrix of molecular imaging technologies

    International Nuclear Information System (INIS)

    Meikle, Steven R; Kench, Peter; Kassiou, Michael; Banati, Richard B

    2005-01-01

    Molecular imaging refers to the use of non-invasive imaging techniques to detect signals that originate from molecules, often in the form of an injected tracer, and observe their interaction with a specific cellular target in vivo. Differences in the underlying physical principles of these measurement techniques determine the sensitivity, specificity and length of possible observation of the signal, characteristics that have to be traded off according to the biological question under study. Here, we describe the specific characteristics of single photon emission computed tomography (SPECT) relative to other molecular imaging technologies. SPECT is based on the tracer principle and external radiation detection. It is capable of measuring the biodistribution of minute ( -10 molar) concentrations of radio-labelled biomolecules in vivo with sub-millimetre resolution and quantifying the molecular kinetic processes in which they participate. Like some other imaging techniques, SPECT was originally developed for human use and was subsequently adapted for imaging small laboratory animals at high spatial resolution for basic and translational research. Its unique capabilities include (i) the ability to image endogenous ligands such as peptides and antibodies due to the relative ease of labelling these molecules with technetium or iodine (ii) the ability to measure relatively slow kinetic processes (compared with positron emission tomography, for example) due to the long half-life of the commonly used isotopes and (iii) the ability to probe two or more molecular pathways simultaneously by detecting isotopes with different emission energies. In this paper, we review the technology developments and design tradeoffs that led to the current state-of-the-art in SPECT small animal scanning and describe the position SPECT occupies within the matrix of molecular imaging technologies. (topical review)

  7. Small animals bone density and morphometry analysis with a dual energy X-rays absorptiometry bone densitometer using a 2D digital radiographic detector

    International Nuclear Information System (INIS)

    Boudousq, V.; Bordy, T.; Gonon, G.; Dinten, J.M.

    2004-01-01

    LEXXOS (DMS, Montpellier, France) is the first axial and total body cone beam bone densitometer using a 2D digital radiographic detector. In previous papers, technical principles and patients' Bone Mineral Density (BMD) measurement performances were presented. Bone densitometers are also used on small animals for drug development. In this presentation, we show how LEXXOS can be adapted for small animals' examinations and evaluate its performances. At first, in order to take advantage of the whole area of the 20 x 20 cm 2 digital radiographic detector, it has been made profit of X-Rays magnification by adapting the geometrical configuration. Secondly, as small animals present low BMD, a specific dual energy calibration has been defined. This adapted system has then been evaluated on two sets of mice: six reference mice and six ovariectomized mice. Each month, these two populations have been examined and the averaged total body BMD has been measured. This evaluation shows that the right order of BMD magnitude is obtained and, as expected, BMD increases on two sets until a period around puberty and the ovariectomized set presents a significant decrease after. Moreover, the bone image obtained by dual energy processing on LEXXOS presents a radiographic image quality providing useful complementary information on bone morphometry and architecture. This study shows that LEXXOS cone beam bone densitometer provides simultaneously useful quantitative and qualitative information for analysis of bone evolution on small animals. In the future, same system architecture and processing methodology can be used with higher resolution detectors in order to refine information on bone architecture. (authors)

  8. Microbiological Standardization in Small Laboratory Animals and Recommendations for the Monitoring

    OpenAIRE

    Meral Karaman

    2014-01-01

    Microbiological standardization in laboratory animal breeding is based on the classification according to the microorganisms that the animals host and consequently their upbringing environment, as well as the certification of their microbiological status and the protection of their properties. Although there are many different classifications for microbiological standardization of laboratory animals, they can be basically classified as; gnotobiotic animals, animals bred with a complete barrie...

  9. Quantitative trait loci for live animal and carcass composition traits in Jersey and Limousin back-cross cattle finished on pasture or feedlot.

    Science.gov (United States)

    Morris, C A; Pitchford, W S; Cullen, N G; Esmailizadeh, A K; Hickey, S M; Hyndman, D; Dodds, K G; Afolayan, R A; Crawford, A M; Bottema, C D K

    2009-10-01

    A quantitative trait locus (QTL) study was carried out in two countries, recording live animal and carcass composition traits. Back-cross calves (385 heifers and 398 steers) were generated, with Jersey and Limousin breed backgrounds. The New Zealand cattle were reared on pasture to carcass weights averaging 229 kg, whilst the Australian cattle were reared on grass and finished on grain (for at least 180 days) to carcass weights averaging 335 kg. From 11 live animal traits and 31 carcass composition traits respectively, 5 and 22 QTL were detected in combined-sire analyses, which were significant (P < 0.05) on a genome-wise basis. Fourteen significant traits for carcass composition QTL were on chromosome 2 and these were traits associated with muscling and fatness. This chromosome carried a variant myostatin allele (F94L), segregating from the Limousin ancestry. Despite very different cattle management systems between the two countries, the two populations had a large number of QTL in common. Of the 18 traits which were common to both countries, and which had significant QTL at the genome-wise level, eight were significant in both countries.

  10. The '3Is' of animal experimentation.

    Science.gov (United States)

    2012-05-29

    Animal experimentation in scientific research is a good thing: important, increasing and often irreplaceable. Careful experimental design and reporting are at least as important as attention to welfare in ensuring that the knowledge we gain justifies using live animals as experimental tools.

  11. First results in the application of silicon photomultiplier matrices to small animal PET

    Energy Technology Data Exchange (ETDEWEB)

    Llosa, G. [University of Pisa, Department of Physics, Pisa (Italy)], E-mail: gabriela.llosa@pi.infn.it; Belcari, N.; Bisogni, M.G. [University of Pisa, Department of Physics, Pisa (Italy); INFN Pisa (Italy); Collazuol, G. [University of Pisa, Department of Physics, Pisa (Italy); Scuola Normale Superiore, Pisa (Italy); Marcatili, S. [University of Pisa, Department of Physics, Pisa (Italy); INFN Pisa (Italy); Boscardin, M.; Melchiorri, M.; Tarolli, A.; Piemonte, C.; Zorzi, N. [FBK irst, Trento (Italy); Barrillon, P.; Bondil-Blin, S.; Chaumat, V.; La Taille, C. de; Dinu, N.; Puill, V.; Vagnucci, J-F. [Laboratoire de l' Accelerateur Lineaire, IN2P3-CNRS, Orsay (France); Del Guerra, A. [University of Pisa, Department of Physics, Pisa (Italy); INFN Pisa (Italy)

    2009-10-21

    A very high resolution small animal PET scanner that employs matrices of silicon photomultipliers as photodetectors is under development at the University of Pisa and INFN Pisa. The first SiPM matrices composed of 16 (4x4)1mmx1mm pixel elements on a common substrate have been produced at FBK-irst, and are being evaluated for this application. The MAROC2 ASIC developed at LAL-Orsay has been employed for the readout of the SiPM matrices. The devices have been tested with pixelated and continuous LYSO crystals. The results show the good performance of the matrices and lead to the fabrication of matrices with 64 SiPM elements.

  12. First results in the application of silicon photomultiplier matrices to small animal PET

    International Nuclear Information System (INIS)

    Llosa, G.; Belcari, N.; Bisogni, M.G.; Collazuol, G.; Marcatili, S.; Boscardin, M.; Melchiorri, M.; Tarolli, A.; Piemonte, C.; Zorzi, N.; Barrillon, P.; Bondil-Blin, S.; Chaumat, V.; La Taille, C. de; Dinu, N.; Puill, V.; Vagnucci, J-F.; Del Guerra, A.

    2009-01-01

    A very high resolution small animal PET scanner that employs matrices of silicon photomultipliers as photodetectors is under development at the University of Pisa and INFN Pisa. The first SiPM matrices composed of 16 (4x4)1mmx1mm pixel elements on a common substrate have been produced at FBK-irst, and are being evaluated for this application. The MAROC2 ASIC developed at LAL-Orsay has been employed for the readout of the SiPM matrices. The devices have been tested with pixelated and continuous LYSO crystals. The results show the good performance of the matrices and lead to the fabrication of matrices with 64 SiPM elements.

  13. Zebrafish response to robotic fish: preference experiments on isolated individuals and small shoals

    International Nuclear Information System (INIS)

    Polverino, G; Abaid, N; Kopman, V; Porfiri, M; Macrì, S

    2012-01-01

    Recently developed bioinspired robots imitate their live counterparts in both aspect and functionality. Nevertheless, whether these devices can be integrated within the ecological niche inspiring their design is seldom tested experimentally. An elemental research question concerns the feasibility of modulating spontaneous behaviour of animal systems through bioinspired robotics. The following study explores the possibility of engineering a robotic fish capable of influencing the behaviour of live zebrafish (Danio rerio) in a dichotomous preference test. While we observe that the preference for the robotic fish never exceeds the preference for a conspecific, our data show that the robot is successful in attracting both isolated individuals and small shoals and that such capability is influenced by its bioinspired features. In particular, we find that the robot's undulations enhance its degree of attractiveness, despite the noise inherent in the actuation system. This is the first experimental evidence that live zebrafish behaviour can be influenced by engineered robots. Such robotic platforms may constitute a valuable tool to investigate the bases of social behaviour and uncover the fundamental determinants of animal functions and dysfunctions. (paper)

  14. Use of 5-mm Laparoscopic Stapler to Perform Open Small Bowel Anastomosis in a Neonatal Animal Model.

    Science.gov (United States)

    Glenn, Ian C; Bruns, Nicholas E; Ponsky, Todd A

    2016-10-01

    While adult bowel anastomoses are typically performed with staplers, neonatal small bowel anastomoses have traditionally been performed in a hand-sewn manner due to the large size of surgical staplers. The purpose of this study was to compare stapled anastomosis using a newly available, 5-mm laparoscopic stapler to a hand-sewn anastomosis in an open animal model. Twenty anastomoses were performed by two general surgery residents (10 stapled and 10 hand-sewn) in an adult New Zealand white rabbit. The small bowel was divided with a scalpel. Surgical technique was alternated between single-layer hand-sewn and stapled anastomoses. Each anastomosis was resected for ex vivo testing. Measurements collected were outer diameter of the bowel before division, time to perform the anastomosis, anastomosis inner diameter (ID), and leak test. IDs were measured by cutting the anastomosis in cross-section, taking a photograph, and measuring the diameter by computer software. In addition, the surgeons qualitatively evaluated the anastomoses for hemostasis and overall quality. Statistical significance was determined using the Student's t-test. There were statistically significant differences between stapled and hand-sewn anastomosis, respectively, for average operative time (4 minutes 2 seconds versus 16 minutes 6 seconds, P animal model, a 5-mm stapled anastomosis is an acceptable alternative to hand-sewn small bowel anastomosis. The stapler is faster and creates a larger diameter anastomosis, however, there was one leak when closing the enterotomy in the stapled group and overlapping staple lines should be avoided.

  15. A framework for inverse planning of beam-on times for 3D small animal radiotherapy using interactive multi-objective optimisation

    International Nuclear Information System (INIS)

    Balvert, Marleen; Den Hertog, Dick; Van Hoof, Stefan J; Granton, Patrick V; Trani, Daniela; Hoffmann, Aswin L; Verhaegen, Frank

    2015-01-01

    Advances in precision small animal radiotherapy hardware enable the delivery of increasingly complicated dose distributions on the millimeter scale. Manual creation and evaluation of treatment plans becomes difficult or even infeasible with an increasing number of degrees of freedom for dose delivery and available image data. The goal of this work is to develop an optimisation model that determines beam-on times for a given beam configuration, and to assess the feasibility and benefits of an automated treatment planning system for small animal radiotherapy.The developed model determines a Pareto optimal solution using operator-defined weights for a multiple-objective treatment planning problem. An interactive approach allows the planner to navigate towards, and to select the Pareto optimal treatment plan that yields the most preferred trade-off of the conflicting objectives. This model was evaluated using four small animal cases based on cone-beam computed tomography images. Resulting treatment plan quality was compared to the quality of manually optimised treatment plans using dose-volume histograms and metrics.Results show that the developed framework is well capable of optimising beam-on times for 3D dose distributions and offers several advantages over manual treatment plan optimisation. For all cases but the simple flank tumour case, a similar amount of time was needed for manual and automated beam-on time optimisation. In this time frame, manual optimisation generates a single treatment plan, while the inverse planning system yields a set of Pareto optimal solutions which provides quantitative insight on the sensitivity of conflicting objectives. Treatment planning automation decreases the dependence on operator experience and allows for the use of class solutions for similar treatment scenarios. This can shorten the time required for treatment planning and therefore increase animal throughput. In addition, this can improve treatment standardisation and

  16. Assessing Monkeypox Virus Prevalence in Small Mammals at the Human–Animal Interface in the Democratic Republic of the Congo

    Directory of Open Access Journals (Sweden)

    Jeffrey B. Doty

    2017-10-01

    Full Text Available During 2012, 2013 and 2015, we collected small mammals within 25 km of the town of Boende in Tshuapa Province, the Democratic Republic of the Congo. The prevalence of monkeypox virus (MPXV in this area is unknown; however, cases of human infection were previously confirmed near these collection sites. Samples were collected from 353 mammals (rodents, shrews, pangolins, elephant shrews, a potamogale, and a hyrax. Some rodents and shrews were captured from houses where human monkeypox cases have recently been identified, but most were trapped in forests and agricultural areas near villages. Real-time PCR and ELISA were used to assess evidence of MPXV infection and other Orthopoxvirus (OPXV infections in these small mammals. Seven (2.0% of these animal samples were found to be anti-orthopoxvirus immunoglobulin G (IgG antibody positive (six rodents: two Funisciurus spp.; one Graphiurus lorraineus; one Cricetomys emini; one Heliosciurus sp.; one Oenomys hypoxanthus, and one elephant shrew Petrodromus tetradactylus; no individuals were found positive in PCR-based assays. These results suggest that a variety of animals can be infected with OPXVs, and that epidemiology studies and educational campaigns should focus on animals that people are regularly contacting, including larger rodents used as protein sources.

  17. Assessing Monkeypox Virus Prevalence in Small Mammals at the Human-Animal Interface in the Democratic Republic of the Congo.

    Science.gov (United States)

    Doty, Jeffrey B; Malekani, Jean M; Kalemba, Lem's N; Stanley, William T; Monroe, Benjamin P; Nakazawa, Yoshinori U; Mauldin, Matthew R; Bakambana, Trésor L; Liyandja Dja Liyandja, Tobit; Braden, Zachary H; Wallace, Ryan M; Malekani, Divin V; McCollum, Andrea M; Gallardo-Romero, Nadia; Kondas, Ashley; Peterson, A Townsend; Osorio, Jorge E; Rocke, Tonie E; Karem, Kevin L; Emerson, Ginny L; Carroll, Darin S

    2017-10-03

    During 2012, 2013 and 2015, we collected small mammals within 25 km of the town of Boende in Tshuapa Province, the Democratic Republic of the Congo. The prevalence of monkeypox virus (MPXV) in this area is unknown; however, cases of human infection were previously confirmed near these collection sites. Samples were collected from 353 mammals (rodents, shrews, pangolins, elephant shrews, a potamogale, and a hyrax). Some rodents and shrews were captured from houses where human monkeypox cases have recently been identified, but most were trapped in forests and agricultural areas near villages. Real-time PCR and ELISA were used to assess evidence of MPXV infection and other Orthopoxvirus (OPXV) infections in these small mammals. Seven (2.0%) of these animal samples were found to be anti-orthopoxvirus immunoglobulin G (IgG) antibody positive (six rodents: two Funisciurus spp.; one Graphiurus lorraineus ; one Cricetomys emini ; one Heliosciurus sp.; one Oenomys hypoxanthus , and one elephant shrew Petrodromus tetradactylus ); no individuals were found positive in PCR-based assays. These results suggest that a variety of animals can be infected with OPXVs, and that epidemiology studies and educational campaigns should focus on animals that people are regularly contacting, including larger rodents used as protein sources.

  18. LED and Semiconductor Photo-effects on Living Things

    Science.gov (United States)

    Fujiyasu, Hiroshi; Ishigaki, Takemitsu; Fujiyasu, Kentarou; Ujihara, Shirou; Watanabe, Naoharu; Sunayama, Shunji; Ikoma, Shuuji

    We have studied LED irradiation effects on plants and animals in the visible to UV region of light from GaN LEDs. The results are as follows. Blue light considers to be effective for pearl cultivation or for attraction of small fishes living in near the surface of sea such as Pompano or Sardine, white light radiation is effective for cultivation of botanical plankton for shells. Other experiments of UV light irradiation attracting effect on baby sea turtle and the germination UV effect of mushroom, green light weight enhance effect on baby pigs, light vernalization effect of vegitable and Ge far infrared therapic effect on human body are also given.

  19. Small Animal Models for Human Metapneumovirus: Cotton Rat is More Permissive than Hamster and Mouse

    Science.gov (United States)

    Zhang, Yu; Niewiesk, Stefan; Li, Jianrong

    2014-01-01

    Human metapneumovirus (hMPV) is the second most prevalent causative agent of pediatric respiratory infections worldwide. Currently, there are no vaccines or antiviral drugs against this virus. One of the major hurdles in hMPV research is the difficulty to identify a robust small animal model to accurately evaluate the efficacy and safety of vaccines and therapeutics. In this study, we compared the replication and pathogenesis of hMPV in BALB/c mice, Syrian golden hamsters, and cotton rats. It was found that BALB/c mice are not permissive for hMPV infection despite the use of a high dose (6.5 log10 PFU) of virus for intranasal inoculation. In hamsters, hMPV replicated efficiently in nasal turbinates but demonstrated only limited replication in lungs. In cotton rats, hMPV replicated efficiently in both nasal turbinate and lung when intranasally administered with three different doses (4, 5, and 6 log10 PFU) of hMPV. Lungs of cotton rats infected by hMPV developed interstitial pneumonia with mononuclear cells infiltrates and increased lumen exudation. By immunohistochemistry, viral antigens were detected at the luminal surfaces of the bronchial epithelial cells in lungs. Vaccination of cotton rats with hMPV completely protected upper and lower respiratory tract from wildtype challenge. The immunization also elicited elevated serum neutralizing antibody. Collectively, these results demonstrated that cotton rat is a robust small animal model for hMPV infection. PMID:25438015

  20. High throughput static and dynamic small animal imaging using clinical PET/CT: potential preclinical applications

    International Nuclear Information System (INIS)

    Aide, Nicolas; Desmonts, Cedric; Agostini, Denis; Bardet, Stephane; Bouvard, Gerard; Beauregard, Jean-Mathieu; Roselt, Peter; Neels, Oliver; Beyer, Thomas; Kinross, Kathryn; Hicks, Rodney J.

    2010-01-01

    The objective of the study was to evaluate state-of-the-art clinical PET/CT technology in performing static and dynamic imaging of several mice simultaneously. A mouse-sized phantom was imaged mimicking simultaneous imaging of three mice with computation of recovery coefficients (RCs) and spillover ratios (SORs). Fifteen mice harbouring abdominal or subcutaneous tumours were imaged on clinical PET/CT with point spread function (PSF) reconstruction after injection of [18F]fluorodeoxyglucose or [18F]fluorothymidine. Three of these mice were imaged alone and simultaneously at radial positions -5, 0 and 5 cm. The remaining 12 tumour-bearing mice were imaged in groups of 3 to establish the quantitative accuracy of PET data using ex vivo gamma counting as the reference. Finally, a dynamic scan was performed in three mice simultaneously after the injection of 68 Ga-ethylenediaminetetraacetic acid (EDTA). For typical lesion sizes of 7-8 mm phantom experiments indicated RCs of 0.42 and 0.76 for ordered subsets expectation maximization (OSEM) and PSF reconstruction, respectively. For PSF reconstruction, SOR air and SOR water were 5.3 and 7.5%, respectively. A strong correlation (r 2 = 0.97, p 2 = 0.98; slope = 0.89, p 2 = 0.96; slope = 0.62, p 68 Ga-EDTA dynamic acquisition. New generation clinical PET/CT can be used for simultaneous imaging of multiple small animals in experiments requiring high throughput and where a dedicated small animal PET system is not available. (orig.)

  1. Anatomical and metabolic small-animal whole-body imaging using ring-shaped confocal photoacoustic computed tomography

    Science.gov (United States)

    Xia, Jun; Chatni, Muhammad; Maslov, Konstantin; Wang, Lihong V.

    2013-03-01

    Due to the wide use of animals for human disease studies, small animal whole-body imaging plays an increasingly important role in biomedical research. Currently, none of the existing imaging modalities can provide both anatomical and glucose metabolic information, leading to higher costs of building dual-modality systems. Even with image coregistration, the spatial resolution of the metabolic imaging modality is not improved. We present a ring-shaped confocal photoacoustic computed tomography (RC-PACT) system that can provide both assessments in a single modality. Utilizing the novel design of confocal full-ring light delivery and ultrasound transducer array detection, RC-PACT provides full-view cross-sectional imaging with high spatial resolution. Scanning along the orthogonal direction provides three-dimensional imaging. While the mouse anatomy was imaged with endogenous hemoglobin contrast, the glucose metabolism was imaged with a near-infrared dye-labeled 2-deoxyglucose. Through mouse tumor models, we demonstrate that RC-PACT may be a paradigm shifting imaging method for preclinical research.

  2. A small animal PET based on GAPDs and charge signal transmission approach for hybrid PET-MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Jihoon; Choi, Yong; Hong, Key Jo; Hu, Wei; Jung, Jin Ho; Huh, Yoonsuk [Department of Electronic Engineering, Sogang University, 1 Shinsu-Dong, Mapo-Gu, Seoul 121-742 (Korea, Republic of); Kim, Byung-Tae, E-mail: ychoi.image@gmail.com [Department of Nuclear Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Ilwon-Dong, Gangnam-Gu, Seoul 135-710 (Korea, Republic of)

    2011-08-15

    Positron emission tomography (PET) employing Geiger-mode avalanche photodiodes (GAPDs) and charge signal transmission approach was developed for small animal imaging. Animal PET contained 16 LYSO and GAPD detector modules that were arranged in a 70 mm diameter ring with an axial field of view of 13 mm. The GAPDs charge output signals were transmitted to a preamplifier located remotely using 300 cm flexible flat cables. The position decoder circuits (PDCs) were used to multiplex the PET signals from 256 to 4 channels. The outputs of the PDCs were digitized and further-processed in the data acquisition unit. The cross-compatibilities of the PET detectors and MRI were assessed outside and inside the MRI. Experimental studies of the developed full ring PET were performed to examine the spatial resolution and sensitivity. Phantom and mouse images were acquired to examine the imaging performance. The mean energy and time resolution of the PET detector were 17.6% and 1.5 ns, respectively. No obvious degradation on PET and MRI was observed during simultaneous PET-MRI data acquisition. The measured spatial resolution and sensitivity at the CFOV were 2.8 mm and 0.7%, respectively. In addition, a 3 mm diameter line source was clearly resolved in the hot-sphere phantom images. The reconstructed transaxial PET images of the mouse brain and tumor displaying the glucose metabolism patterns were imaged well. These results demonstrate GAPD and the charge signal transmission approach can allow the development of high performance small animal PET with improved MR compatibility.

  3. Morally relevant differences between animals and human beings justifying the use of animals in biomedical research.

    Science.gov (United States)

    Dennis, J U

    1997-03-01

    I have attempted to show that the differential qualities of animals and human beings indeed to have bearing on moral rules and the derivation of rights, including rights established on the basis of reason and utilitarianism. Special rights for members of our species are not simply a consequence of human domination and self-interest. I also have tried to show that rights arise from values and that the qualities we value most highly often are the ones that distinguish human beings from other species. I maintain that giving more value to human lives over animal lives achieves reflective balance with the commonsense notions that most of us have developed. Because utilitarianism, contractualism, and the classical philosophical methods of Kant and Aristotle all may allow favoring human interests over animal interests, it seems reasonable to suspect that animal rights activists embrace narrow, extremist views. There are many uniquely human experiences to which we ascribe high value-deep interpersonal relationships, achieving a life's goal, enjoying a complex cultural event such as a play or an opera, or authoring a manuscript. Therefore, it would seem improper that social and ethical considerations regarding animals be centered entirely on the notion of a biological continuum, because there are many kinds of human experience-moral, religious, aesthetic, and otherwise-that appear to be outside the realm of biology. Knowledge about the biology of animals is helpful for making moral decisions about our obligations to them. Why, then, is there a substantial population of animal rights activists in Europe, the United States, and throughout the world, who would not agree with my conclusions? Certain habitual ways of thinking may encourage anthropomorphism and equating animal interests with human interests. Certain metaphysical beliefs, such as a belief in reincarnation, also might favor animal rights. It also is possible that a number of people are being deceived and misled by

  4. Low cost venom extractor based on Arduino(®) board for electrical venom extraction from arthropods and other small animals.

    Science.gov (United States)

    Besson, Thomas; Debayle, Delphine; Diochot, Sylvie; Salinas, Miguel; Lingueglia, Eric

    2016-08-01

    Extracting venom from small species is usually challenging. We describe here an affordable and versatile electrical venom extractor based on the Arduino(®) Mega 2560 Board, which is designed to extract venom from arthropods and other small animals. The device includes fine tuning of stimulation time and voltage. It was used to collect venom without apparent deleterious effects, and characterized for the first time the venom of Zoropsis spinimana, a common spider in French Mediterranean regions. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. WE-AB-207B-10: On Spinal Nerve Toxicity from Single-Session SAbR in Pigs and the Translation of Small Animal NTCP Models

    Energy Technology Data Exchange (ETDEWEB)

    Hrycushko, B; Medin, P [UT Southwestern Medical Center, Dallas, TX (United States)

    2016-06-15

    Purpose: The incidence of peripheral neuropathy has risen with increased utilization of SAbR. There is no consensus regarding the dose-tolerance of the peripheral nervous system. In 2015, we commenced an investigation to test the hypotheses that single-session irradiation to the pig spinal nerves exhibit a similar dose-tolerance as that of the spinal cord and that a dose-length effect exists. This work evaluates the direct application of small animal NTCP models to both large animal spinal cord and preliminary peripheral nerve data. Methods: To date, 16 of 25 Yucatan minipigs have received single-session SAbR to a 1.5cm length and 4 of 25 have received irradiation to a 0.5cm length of left-sided C6-C8 spinal nerves. Toxicity related gait change has been observed in 13 animals (9 from the long length group and 4 from the short). This preliminary data is overlaid on several dose-response models which have been fit to rodent spinal cord tolerance experiments. Model parameters define a toxicity profile between a completely serial or parallel behaving organ. Adequacy of model application, including how length effects are handled, to published minipig spinal cord dose-response data and to preliminary peripheral nerve response data was evaluated through residual analysis. Results: No rodent-derived dose-response models were directly applicable to all pig data for the different lengths irradiated. Several models fit the long-length irradiated spinal cord data well, with the more serial-like models fitting best. Preliminary data on the short-length irradiation suggests no length effect exists, disproving our hypothesis. Conclusion: Direct application of small-animal NTCP models to pig data suggests dose-length effect predictions from small animal data may not translate clinically. However, the small animal models used have not considered dose heterogeneity and it is expected that including the low-to-mid dose levels in the penumbral region will improve this match. This work

  6. WE-AB-207B-10: On Spinal Nerve Toxicity from Single-Session SAbR in Pigs and the Translation of Small Animal NTCP Models

    International Nuclear Information System (INIS)

    Hrycushko, B; Medin, P

    2016-01-01

    Purpose: The incidence of peripheral neuropathy has risen with increased utilization of SAbR. There is no consensus regarding the dose-tolerance of the peripheral nervous system. In 2015, we commenced an investigation to test the hypotheses that single-session irradiation to the pig spinal nerves exhibit a similar dose-tolerance as that of the spinal cord and that a dose-length effect exists. This work evaluates the direct application of small animal NTCP models to both large animal spinal cord and preliminary peripheral nerve data. Methods: To date, 16 of 25 Yucatan minipigs have received single-session SAbR to a 1.5cm length and 4 of 25 have received irradiation to a 0.5cm length of left-sided C6-C8 spinal nerves. Toxicity related gait change has been observed in 13 animals (9 from the long length group and 4 from the short). This preliminary data is overlaid on several dose-response models which have been fit to rodent spinal cord tolerance experiments. Model parameters define a toxicity profile between a completely serial or parallel behaving organ. Adequacy of model application, including how length effects are handled, to published minipig spinal cord dose-response data and to preliminary peripheral nerve response data was evaluated through residual analysis. Results: No rodent-derived dose-response models were directly applicable to all pig data for the different lengths irradiated. Several models fit the long-length irradiated spinal cord data well, with the more serial-like models fitting best. Preliminary data on the short-length irradiation suggests no length effect exists, disproving our hypothesis. Conclusion: Direct application of small-animal NTCP models to pig data suggests dose-length effect predictions from small animal data may not translate clinically. However, the small animal models used have not considered dose heterogeneity and it is expected that including the low-to-mid dose levels in the penumbral region will improve this match. This work

  7. Accuracy and Radiation Dose of CT-Based Attenuation Correction for Small Animal PET: A Monte Carlo Simulation Study

    International Nuclear Information System (INIS)

    Yang, Ching-Ching; Chan, Kai-Chieh

    2013-06-01

    -Small animal PET allows qualitative assessment and quantitative measurement of biochemical processes in vivo, but the accuracy and reproducibility of imaging results can be affected by several parameters. The first aim of this study was to investigate the performance of different CT-based attenuation correction strategies and assess the resulting impact on PET images. The absorbed dose in different tissues caused by scanning procedures was also discussed to minimize biologic damage generated by radiation exposure due to PET/CT scanning. A small animal PET/CT system was modeled based on Monte Carlo simulation to generate imaging results and dose distribution. Three energy mapping methods, including the bilinear scaling method, the dual-energy method and the hybrid method which combines the kVp conversion and the dual-energy method, were investigated comparatively through assessing the accuracy of estimating linear attenuation coefficient at 511 keV and the bias introduced into PET quantification results due to CT-based attenuation correction. Our results showed that the hybrid method outperformed the bilinear scaling method, while the dual-energy method achieved the highest accuracy among the three energy mapping methods. Overall, the accuracy of PET quantification results have similar trend as that for the estimation of linear attenuation coefficients, whereas the differences between the three methods are more obvious in the estimation of linear attenuation coefficients than in the PET quantification results. With regards to radiation exposure from CT, the absorbed dose ranged between 7.29-45.58 mGy for 50-kVp scan and between 6.61-39.28 mGy for 80-kVp scan. For 18 F radioactivity concentration of 1.86x10 5 Bq/ml, the PET absorbed dose was around 24 cGy for tumor with a target-to-background ratio of 8. The radiation levels for CT scans are not lethal to the animal, but concurrent use of PET in longitudinal study can increase the risk of biological effects. The

  8. Dry coupling for whole-body small-animal photoacoustic computed tomography

    OpenAIRE

    Yeh, Chenghung; Li, Lei; Zhu, Liren; Xia, Jun; Li, Chiye; Chen, Wanyi; Garcia-Uribe, Alejandro; Maslov, Konstantin I.; Wang, Lihong V.

    2017-01-01

    We have enhanced photoacoustic computed tomography with dry acoustic coupling that eliminates water immersion anxiety and wrinkling of the animal and facilitates incorporating complementary modalities and procedures. The dry acoustic coupler is made of a tubular elastic membrane enclosed by a closed transparent water tank. The tubular membrane ensures water-free contact with the animal, and the closed water tank allows pressurization for animal stabilization. The dry coupler was tested using ...

  9. New design of a quasi-monolithic detector module with DOI capability for small animal pet

    International Nuclear Information System (INIS)

    Chung, Yong Hyun; Lee, Seung-Jae; Baek, Cheol-Ha; Choi, Yong

    2008-01-01

    We report a new design of a detector module with depth of interaction (DOI) based on a quasi-monolithic LSO crystal, a multi-channel sensor, and maximum-likelihood position-estimation (MLPE) algorithm. Light transport and detection were modeled in a quasi-monolithic crystal using DETECT2000 code, with lookup tables (LUTs) built by simulation. Events were well separated by applying the MLPE method within 2.0 mm spatial resolution in both trans-axial and DOI directions. These results demonstrate that the proposed detector provides dependable positioning capability for small animal positron emission tomography (PET)

  10. 19 CFR 10.76 - Game animals and birds.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 1 2010-04-01 2010-04-01 false Game animals and birds. 10.76 Section 10.76... TREASURY ARTICLES CONDITIONALLY FREE, SUBJECT TO A REDUCED RATE, ETC. General Provisions Animals and Birds § 10.76 Game animals and birds. (a) The following classes of live game animals and birds may be...

  11. Comprehensive small animal imaging strategies on a clinical 3 T dedicated head MR-scanner; adapted methods and sequence protocols in CNS pathologies.

    Directory of Open Access Journals (Sweden)

    Deepu R Pillai

    Full Text Available BACKGROUND: Small animal models of human diseases are an indispensable aspect of pre-clinical research. Being dynamic, most pathologies demand extensive longitudinal monitoring to understand disease mechanisms, drug efficacy and side effects. These considerations often demand the concomitant development of monitoring systems with sufficient temporal and spatial resolution. METHODOLOGY AND RESULTS: This study attempts to configure and optimize a clinical 3 Tesla magnetic resonance scanner to facilitate imaging of small animal central nervous system pathologies. The hardware of the scanner was complemented by a custom-built, 4-channel phased array coil system. Extensive modification of standard sequence protocols was carried out based on tissue relaxometric calculations. Proton density differences between the gray and white matter of the rodent spinal cord along with transverse relaxation due to magnetic susceptibility differences at the cortex and striatum of both rats and mice demonstrated statistically significant differences. The employed parallel imaging reconstruction algorithms had distinct properties dependent on the sequence type and in the presence of the contrast agent. The attempt to morphologically phenotype a normal healthy rat brain in multiple planes delineated a number of anatomical regions, and all the clinically relevant sequels following acute cerebral ischemia could be adequately characterized. Changes in blood-brain-barrier permeability following ischemia-reperfusion were also apparent at a later time. Typical characteristics of intra-cerebral haemorrhage at acute and chronic stages were also visualized up to one month. Two models of rodent spinal cord injury were adequately characterized and closely mimicked the results of histological studies. In the employed rodent animal handling system a mouse model of glioblastoma was also studied with unequivocal results. CONCLUSIONS: The implemented customizations including extensive

  12. Comprehensive Small Animal Imaging Strategies on a Clinical 3 T Dedicated Head MR-Scanner; Adapted Methods and Sequence Protocols in CNS Pathologies

    Science.gov (United States)

    Pillai, Deepu R.; Heidemann, Robin M.; Lanz, Titus; Dittmar, Michael S.; Sandner, Beatrice; Beier, Christoph P.; Weidner, Norbert; Greenlee, Mark W.; Schuierer, Gerhard; Bogdahn, Ulrich; Schlachetzki, Felix

    2011-01-01

    Background Small animal models of human diseases are an indispensable aspect of pre-clinical research. Being dynamic, most pathologies demand extensive longitudinal monitoring to understand disease mechanisms, drug efficacy and side effects. These considerations often demand the concomitant development of monitoring systems with sufficient temporal and spatial resolution. Methodology and Results This study attempts to configure and optimize a clinical 3 Tesla magnetic resonance scanner to facilitate imaging of small animal central nervous system pathologies. The hardware of the scanner was complemented by a custom-built, 4-channel phased array coil system. Extensive modification of standard sequence protocols was carried out based on tissue relaxometric calculations. Proton density differences between the gray and white matter of the rodent spinal cord along with transverse relaxation due to magnetic susceptibility differences at the cortex and striatum of both rats and mice demonstrated statistically significant differences. The employed parallel imaging reconstruction algorithms had distinct properties dependent on the sequence type and in the presence of the contrast agent. The attempt to morphologically phenotype a normal healthy rat brain in multiple planes delineated a number of anatomical regions, and all the clinically relevant sequels following acute cerebral ischemia could be adequately characterized. Changes in blood-brain-barrier permeability following ischemia-reperfusion were also apparent at a later time. Typical characteristics of intra-cerebral haemorrhage at acute and chronic stages were also visualized up to one month. Two models of rodent spinal cord injury were adequately characterized and closely mimicked the results of histological studies. In the employed rodent animal handling system a mouse model of glioblastoma was also studied with unequivocal results. Conclusions The implemented customizations including extensive sequence protocol

  13. Measurement of evaporative water loss in small animals by dew-point hygrometry.

    Science.gov (United States)

    Bernstein, M H; Hudson, D M; Stearns, J M; Hoyt, R W

    1977-08-01

    This paper presents the procedures and equations to be utilized for measurement of evaporative water loss (mw), by use of the dew-point hygrometer, in small animals exposed to air containing water vapor in an open-flow system. The system accounted accurately for the water evaporated from a bubble flask. In addition, hygrometric measurements of pulmocutaneous mw in pigeons (Columba livia, mean mass 0.31 kg) agreed closely with simultaneous gravimetric measurements, utilizing a desiccant in the sample stream, in a manner independently of air temperature (Ta, 20 or 40 degrees C), ambient water vapor pressure (PW, 4-16 10(2) Pa), or mw (5-66 mg-min-1). Evaporation in pigeons was independent of PW at 20 degrees C, but increased with decreasing PW at 40 degrees C, suggesting differences in ventilatory adjustments to changes in PW at the two temperatures.

  14. Establishing a small animal model for evaluating protective immunity against mumps virus.

    Directory of Open Access Journals (Sweden)

    Adrian Pickar

    Full Text Available Although mumps vaccines have been used for several decades, protective immune correlates have not been defined. Recently, mumps outbreaks have occurred in vaccinated populations. To better understand the causes of the outbreaks and to develop means to control outbreaks in mumps vaccine immunized populations, defining protective immune correlates will be critical. Unfortunately, no small animal model for assessing mumps immunity exists. In this study, we evaluated use of type I interferon (IFN alpha/beta receptor knockout mice (IFN-α/βR-/- for such a model. We found these mice to be susceptible to mumps virus administered intranasally and intracranially. Passive transfer of purified IgG from immunized mice protected naïve mice from mumps virus infection, confirming the role of antibody in protection and demonstrating the potential for this model to evaluate mumps immunity.

  15. Determinants of consumer intention to purchase animal-friendly milk.

    Science.gov (United States)

    de Graaf, Sophie; Van Loo, Ellen J; Bijttebier, Jo; Vanhonacker, Filiep; Lauwers, Ludwig; Tuyttens, Frank A M; Verbeke, Wim

    2016-10-01

    Concern about the welfare of production animals is growing among various stakeholders, including the general public. Citizens can influence the market for premium welfare products by expressing public concerns, and consumers-the actors who actually purchase products-can do so through their purchasing behavior. However, current market shares for premium welfare products are small in Europe. To better align purchase behavior with public and individuals' concerns, insight is needed into determinants that influence the intention to purchase premium welfare products. A cross-sectional online survey of 787 Flemish milk consumers was conducted to investigate attitudes toward and intention to purchase animal-friendly milk. More than half of the sample (52.5%) expressed the intention to purchase animal-friendly milk. Linear regression modeling indicated that intention was positively influenced by (1) higher perceived product benefits from animal-friendly milk (milk with more health benefits and higher quality); (2) higher personal importance of extrinsic product attributes such as local production and country of origin; (3) higher personal importance of animal welfare; (4) a more natural living oriented attitude toward cows; and (5) a more positive general attitude toward milk. Intention was negatively influenced by (1) a stronger business-oriented attitude toward cows; and (2) by a higher personal importance attached to price. These insights in key components of purchase intention can assist producers, the dairy industry, and retailers to position and market animal-friendly milk. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  16. Development and applications of TOHR, an original emission tomography system, adapted to small animals

    International Nuclear Information System (INIS)

    Ploux, Lydie

    1997-01-01

    For many neuro-biological studies, it is necessary to link microscopic aspects of the brain's organization with integrated brain functions. Details of the former are obtained by in vitro and in situ molecular biology techniques, whereas the latter are acquired through behavioural studies. In vivo radio-imaging methods, like emission tomography are the ideal tools to investigate the links between these two levels of brain organization. The work which is presented here focuses on a new approach of emission tomography adapted to small animal studies: TOHR (French, acronym for TOmographe Haute Resolution). The principle is based on the use of a large solid angle, high resolution and high efficiency focusing collimator. High resolution and high signal to noise ratio are improved by using nuclides having a two-photon decay with small angular correlation ( 125 I, 123 I, 111 In,...). The image is built step-by-step, by moving the animal relative to the collimator focal point. First, numerical simulation showed the possibility of reaching sub-millimetric resolutions; these results led to the collimator geometry (at present 10 over the 20 faces of an icosahedron, 15 faces in the future). Then, a prototype of TOHR has been built and characterized. Its performance is very close to the numerical prediction: spatial resolution of 1.4 mm and detection efficiency 0.64%. Finally, experiments on a rat thyroid allowed the preparation and realization of the first experiments on a rat striatum. The good quality of these images shows that it is now possible to evaluate TOHR capabilities on a dopaminergic neuron degeneration model in rats in the field of neuro-degenerative disease studies. (author)

  17. Monte Carlo dosimetry of iodine contrast objects in a small animal microCT

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez-Villafuerte, M., E-mail: mercedes@fisica.unam.mx [Instituto de Fisica, Universidad Nacional Autonoma de Mexico, A.P. 20-364, 01000 Mexico D.F. (Mexico); Martinez-Davalos, A. [Instituto de Fisica, Universidad Nacional Autonoma de Mexico, A.P. 20-364, 01000 Mexico D.F. (Mexico)

    2011-08-21

    Small animal microcomputed tomography (microCT) studies with iodine-based contrast media are commonly used in preclinical research. While the use of contrast media improves the quality of the images, it can also result in an increase in the absorbed dose to organs with high concentration of the contrast agent, which might cause radiation damage to the animal. In this work we present the results of a Monte Carlo investigation of a microCT dosimetry study using mouse-sized cylindrical water phantoms with iodine contrast insets for different X-ray spectra (Mo and W targets, 30-80 kVp), iodine concentrations (0, 5, 10 and 15 mg mL{sup -1}) and contrast object sizes (3 and 10 mm diameter). Our results indicate an absorbed dose increase in the contrast-inset regions with respect to the absorbed dose distribution within a reference uniform water phantom. The calculated spatial absorbed dose distributions show large gradients due to beam hardening effects, and large absorbed dose enhancement as the mean energy of the beam and iodine concentration increase. We have found that absorbed doses in iodine contrast objects can increase by a factor of up to 12 for a realistic 80 kVp X-ray spectra and an iodine concentration of 15 mg mL{sup -1}.

  18. Animals as disgust elicitors

    DEFF Research Database (Denmark)

    Kasperbauer, Tyler Joshua

    2015-01-01

    This paper attempts to explain how and why nonhuman animals elicit disgust in human beings. I argue that animals elicit disgust in two ways. One is by triggering disease–protection mechanisms, and the other is by eliciting mortality salience, or thoughts of death. I discuss how these two types...... of disgust operate and defend their conceptual and theoretical coherence against common objections. I also outline an explanatory challenge for disgust researchers. Both types of disgust indicate that a wide variety of animals produce aversive and avoidant reactions in human beings. This seems somewhat odd......, given the prominence of animals in human lives. The challenge, then, is explaining how humans cope with the presence of animals. I propose, as a hypothesis for further exploration, that we cope with animals, and our disgust responses to them, by attributing mental states that mark them as inferior...

  19. Changes in leptospirosis etiology in animals and humans.

    Science.gov (United States)

    Vasylieva, Natalia; Andreychyn, Mykhaylo; Kravchuk, Yulia; Chervinska, Оlena; Iosyk, Iaryna

    2017-12-23

    Leptospirosis is endemic in Ternopil region. In Ukraine, the disease is registered in almost all regions, including the Ternopil region. The aim of the research is to study the regularities of epidemic and epizootic processes of leptospirosis, and the circulation of its pathogens among different sources (small mammals, animals) and humans. Etiologic spectrum of leptospirosis registered in Ternopil region in 1972-2016 among small mammals, farm animals and sick people was studied. Due to the analysis of pathogens circulation among different sources (small mammals, animals), as well as the annual morbidity in humans, it was proved that new leptospira serovars are endemic and brought into the regions mostly by farm animals. Farm animals introduce the infection to humans through the environment, sometimes within 3-5-years. The spread was observed of pathogen serovars, which are new in certain areas, among all types of mouse-like small mammals and rats. It was established that livestock and small mammals are parallel reservoirs. In the regions with endemic species, the structural modification in the etiology of leptospirosis in humans is caused by additional reservoirs among animals, as well as the circulation of other pathogen serovars that were absent in the main natural reservoir, i.e. mouse-like small mammals and rats. The constant monitoring of the population, contamination and carrier state of mouse-like small mammals, rats and farm animals, is required In order to predict the future epidemiological situation on leptospirosis among the population and to improve leptospirosis diagnosis.

  20. Predicting effects of rainforest fragmentation from live trapping studies of small mammals in Sri Lanka

    Directory of Open Access Journals (Sweden)

    M.R. Wijesinghe

    2012-06-01

    Full Text Available This paper examines the impact of forest fragmentation on small mammals inhabiting the rainforests of Sri Lanka. Fifteen forests ranging in size from 145 to 11000 ha were live-trapped for five to eight nights each in both interior and edge habitats, yielding a total of 18400 trap nights. A total of 444 individuals belonging to 10 species of small mammals were captured. Multiple-regression analysis incorporating three indicators of fragmentation: patch area, shape index (perimeter/area and degree of isolation, showed no significant effects on overall species richness of small mammals. This is likely because the decline of forest-adapted species from small forest fragments was accompanied by an increase in more tolerant and adaptive species. Patch size, however, had a significant positive effect on the abundance of small mammals. Of the two dominant species, the endemic Mus mayori was positively affected by patch area whilst Rattus rattus was not affected. Although no differences were evident between interior and edge habitats with respect to total species richness and abundance, endemics were more abundant in core areas while the reverse was true for the non-endemics. Core forest areas were significantly different from forest edges with respect to canopy cover, density of herbaceous vegetation, large trees and litter cover. These results suggest that forest fragmentation is detrimental to some forest specialists and beneficial to some generalists.

  1. Feasibility of a CdTe-based SPECT for high-resolution low-dose small animal imaging: a Monte Carlo simulation study

    International Nuclear Information System (INIS)

    Park, S-J; Yu, A R; Lee, Y-J; Kim, Y-S; Kim, H-J

    2014-01-01

    Dedicated single-photon-emission computed tomography (SPECT) systems based on pixelated semiconductors such as cadmium telluride (CdTe) are in development to study small animal models of human disease. In an effort to develop a high-resolution, low-dose system for small animal imaging, we compared a CdTe-based SPECT system and a conventional NaI(Tl)-based SPECT system in terms of spatial resolution, sensitivity, contrast, and contrast-to-noise ratio (CNR). In addition, we investigated the radiation absorbed dose and calculated a figure of merit (FOM) for both SPECT systems. Using the conventional NaI(Tl)-based SPECT system, we achieved a spatial resolution of 1.66 mm at a 30 mm source-to-collimator distance, and a resolution of 2.4-mm hot-rods. Using the newly-developed CdTe-based SPECT system, we achieved a spatial resolution of 1.32 mm FWHM at a 30 mm source-to-collimator distance, and a resolution of 1.7-mm hot-rods. The sensitivities at a 30 mm source-to-collimator distance were 115.73 counts/sec/MBq and 83.38 counts/sec/MBq for the CdTe-based SPECT and conventional NaI(Tl)-based SPECT systems, respectively. To compare quantitative measurements in the mouse brain, we calculated the CNR for images from both systems. The CNR from the CdTe-based SPECT system was 4.41, while that from the conventional NaI(Tl)-based SPECT system was 3.11 when the injected striatal dose was 160 Bq/voxel. The CNR increased as a function of injected dose in both systems. The FOM of the CdTe-based SPECT system was superior to that of the conventional NaI(Tl)-based SPECT system, and the highest FOM was achieved with the CdTe-based SPECT at a dose of 40 Bq/voxel injected into the striatum. Thus, a CdTe-based SPECT system showed significant improvement in performance compared with a conventional system in terms of spatial resolution, sensitivity, and CNR, while reducing the radiation dose to the small animal subject. Herein, we discuss the feasibility of a CdTe-based SPECT system for high

  2. Filtering and deconvolution for bioluminescence imaging of small animals

    International Nuclear Information System (INIS)

    Akkoul, S.

    2010-01-01

    This thesis is devoted to analysis of bioluminescence images applied to the small animal. This kind of imaging modality is used in cancerology studies. Nevertheless, some problems are related to the diffusion and the absorption of the tissues of the light of internal bioluminescent sources. In addition, system noise and the cosmic rays noise are present. This influences the quality of the images and makes it difficult to analyze. The purpose of this thesis is to overcome these disturbing effects. We first have proposed an image formation model for the bioluminescence images. The processing chain is constituted by a filtering stage followed by a deconvolution stage. We have proposed a new median filter to suppress the random value impulsive noise which corrupts the acquired images; this filter represents the first block of the proposed chain. For the deconvolution stage, we have performed a comparative study of various deconvolution algorithms. It allowed us to choose a blind deconvolution algorithm initialized with the estimated point spread function of the acquisition system. At first, we have validated our global approach by comparing our obtained results with the ground truth. Through various clinical tests, we have shown that the processing chain allows a significant improvement of the spatial resolution and a better distinction of very close tumor sources, what represents considerable contribution for the users of bioluminescence images. (author)

  3. Quantifying the limitations of small animal positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Oxley, D.C. [Department of Physics, University of Liverpool, Liverpool L69 7ZE (United Kingdom)], E-mail: dco@ns.ph.liv.ac.uk; Boston, A.J.; Boston, H.C.; Cooper, R.J.; Cresswell, J.R.; Grint, A.N.; Nolan, P.J.; Scraggs, D.P. [Department of Physics, University of Liverpool, Liverpool L69 7ZE (United Kingdom); Lazarus, I.H. [STFC Daresbury Laboratory, Warrington, WA4 4AD Cheshire (United Kingdom); Beveridge, T.E. [School of Materials and Engineering, Monash University, Melbourne (Australia)

    2009-06-01

    The application of position sensitive semiconductor detectors in medical imaging is a field of global research interest. The Monte-Carlo simulation toolkit GEANT4 [ (http://geant4.web.cern.ch/geant4/)] was employed to improve the understanding of detailed {gamma}-ray interactions within the small animal Positron Emission Tomography (PET), high-purity germanium (HPGe) imaging system, SmartPET [A.J. Boston, et al., Oral contribution, ANL, Chicago, USA, 2006]. This system has shown promising results in the field of PET [R.J. Cooper, et al., Nucl. Instr. and Meth. A (2009), accepted for publication] and Compton camera imaging [J.E. Gillam, et al., Nucl. Instr. and Meth. A 579 (2007) 76]. Images for a selection of single and multiple point, line and phantom sources were successfully reconstructed using both a filtered-back-projection (FBP) [A.R. Mather, Ph.D. Thesis, University of Liverpool, 2007] and an iterative reconstruction algorithm [A.R. Mather, Ph.D. Thesis, University of Liverpool, 2007]. Simulated data were exploited as an alternative route to a reconstructed image allowing full quantification of the image distortions introduced in each phase of the data processing. Quantifying the contribution of uncertainty in all system components from detector to reconstruction algorithm allows the areas in need of most attention on the SmartPET project and semiconductor PET to be addressed.

  4. Performance evaluation of a compact PET/SPECT/CT tri-modality system for small animal imaging applications

    International Nuclear Information System (INIS)

    Wei, Qingyang; Wang, Shi; Ma, Tianyu; Wu, Jing; Liu, Hui; Xu, Tianpeng; Xia, Yan; Fan, Peng; Lyu, Zhenlei; Liu, Yaqiang

    2015-01-01

    PET, SPECT and CT imaging techniques are widely used in preclinical small animal imaging applications. In this paper, we present a compact small animal PET/SPECT/CT tri-modality system. A dual-functional, shared detector design is implemented which enables PET and SPECT imaging with a same LYSO ring detector. A multi-pinhole collimator is mounted on the system and inserted into the detector ring in SPECT imaging mode. A cone-beam CT consisting of a micro focus X-ray tube and a CMOS detector is implemented. The detailed design and the performance evaluations are reported in this paper. In PET imaging mode, the measured NEMA based spatial resolution is 2.12 mm (FWHM), and the sensitivity at the central field of view (CFOV) is 3.2%. The FOV size is 50 mm (∅)×100 mm (L). The SPECT has a spatial resolution of 1.32 mm (FWHM) and an average sensitivity of 0.031% at the center axial, and a 30 mm (∅)×90 mm (L) FOV. The CT spatial resolution is 8.32 lp/mm @10%MTF, and the contrast discrimination function value is 2.06% with 1.5 mm size cubic box object. In conclusion, a compact, tri-modality PET/SPECT/CT system was successfully built with low cost and high performance

  5. Whole-body ring-shaped confocal photoacoustic computed tomography of small animals in vivo

    Science.gov (United States)

    Xia, Jun; Chatni, Muhammad R.; Maslov, Konstantin; Guo, Zijian; Wang, Kun; Anastasio, Mark; Wang, Lihong V.

    2012-05-01

    We report a novel small-animal whole-body imaging system called ring-shaped confocal photoacoustic computed tomography (RC-PACT). RC-PACT is based on a confocal design of free-space ring-shaped light illumination and 512-element full-ring ultrasonic array signal detection. The free-space light illumination maximizes the light delivery efficiency, and the full-ring signal detection ensures a full two-dimensional view aperture for accurate image reconstruction. Using cylindrically focused array elements, RC-PACT can image a thin cross section with 0.10 to 0.25 mm in-plane resolutions and 1.6 s/frame acquisition time. By translating the mouse along the elevational direction, RC-PACT provides a series of cross-sectional images of the brain, liver, kidneys, and bladder.

  6. Cancer screening tests for small animals.

    Science.gov (United States)

    Schleis, Stephanie E

    2014-09-01

    Cancer is increasingly more common. Several tests for the diagnosis and treatment of cancer in companion animals have been developed. Screening tests discussed include those for lymphoid neoplasia, hemangiosarcoma, and transitional cell carcinoma of the bladder. None of these tests should be used in isolation for diagnosis. Vincristine and doxorubicin are mainstays in the treatment of canine lymphoma. However, it is important and accepted practice to test individuals of predisposed breeds for this mutation before administering these drugs in a lymphoma protocol. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Is animal experimentation fundamental?

    Science.gov (United States)

    d'Acampora, Armando José; Rossi, Lucas Félix; Ely, Jorge Bins; de Vasconcellos, Zulmar Acciolli

    2009-01-01

    The understanding about the utilization of experimental animals in scientific research and in teaching is many times a complex issue. Special attention needs to be paid to attain the understanding by the general public of the importance of animal experimentation in experimental research and in undergraduate medical teaching. Experimental teaching and research based on the availability of animals for experimentation is important and necessary for the personal and scientific development of the physician-to-be. The technological arsenal which intends to mimic experimentation animals and thus fully replace their use many times does not prove to be compatible with the reality of the living animal. The purpose of this paper is to discuss aspects concerning this topic, bringing up an issue which is complex and likely to arouse in-depth reflections.

  8. Intersectionality in the Lives of LGBTQ Youth: Identifying as LGBTQ and Finding Community in Small Cities and Rural Towns.

    Science.gov (United States)

    Hulko, Wendy; Hovanes, Jessica

    2018-01-01

    This article presents an analysis of the views of younger bisexual and lesbian women and transgender youth living in a western Canadian small city on their sexual and gender identities. Data were collected through focus groups and interviews and analyzed thematically through an intersectional lens. The purposive sample was composed of 13 youth who identified as lesbian, gay, bisexual, transgender, or queer (LGBTQ) and whose average age was 19.8 years. The analytical themes of (1) living in a small town, (2) identifying and being identified, and (3) talking intersectionality indicate that the sexual identities and gender identities and expressions of LGBTQ youth change across time and context and are impacted by often overlooked factors including faith, Indigenous ancestry, disability, and class. Further, the size and character of the community significantly impacts LGBTQ youth identity development and expression. This research demonstrates the uniqueness of individual youth's experiences-opposing notions of milestone events as singularly important in queer youth identity development.

  9. Living Systems Energy Module

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-09-26

    The Living Systems Energy Module, renamed Voyage from the Sun, is a twenty-lesson curriculum designed to introduce students to the major ways in which energy is important in living systems. Voyage from the Sun tells the story of energy, describing its solar origins, how it is incorporated into living terrestrial systems through photosynthesis, how it flows from plants to herbivorous animals, and from herbivores to carnivores. A significant part of the unit is devoted to examining how humans use energy, and how human impact on natural habitats affects ecosystems. As students proceed through the unit, they read chapters of Voyage from the Sun, a comic book that describes the flow of energy in story form (Appendix A). During the course of the unit, an ``Energy Pyramid`` is erected in the classroom. This three-dimensional structure serves as a classroom exhibit, reminding students daily of the importance of energy and of the fragile nature of our living planet. Interactive activities teach students about adaptations that allow plants and animals to acquire, to use and to conserve energy. A complete list of curricular materials and copies of all activity sheets appear in Appendix B.

  10. MediSPECT: Single photon emission computed tomography system for small field of view small animal imaging based on a CdTe hybrid pixel detector

    International Nuclear Information System (INIS)

    Accorsi, R.; Autiero, M.; Celentano, L.

    2007-01-01

    We describe MediSPECT, a new scanner developed at University and INFN Napoli, for SPECT studies on small animals with a small field of view (FOV) and high spatial resolution. The CdTe pixel detector (a 256x256 matrix of 55 μm square pixels) operating in single photon counting for detection of gamma-rays with low and medium energy (e.g. 125 I, 27-35 keV, 99m Tc, 140 keV), is bump bonded to the Medipix2 readout chip. The FOV of the MediSPECT scanner with a coded aperture mask collimator ranges from 6.3 mm (system spatial resolution 110 μm at 27-35 keV) to 24.3 mm. With a 0.30 mm pinhole the FOV ranges from 2.4 to 29 mm (where the system spatial resolution is 1.0 mm at 27-35 keV and 2.0 mm at 140 keV). MediSPECT will be used for in vivo imaging of small organs or tissue structures in mouse, e.g., brain, thyroid, heart or tumor

  11. [The small pox vaccine: its first century in Brazil (from the Jennerian to the animal vaccine)].

    Science.gov (United States)

    Fernandes, T

    1999-01-01

    Covering a period of roughly hundred years, the article looks at some of the more meaningful events during the period in which the small pox vaccine was institutionalized in Brazil. Discoveries and discussions then taking place in other countries are also examined, particularly as they influenced Brazil. The process is followed from introduction of the human vaccine to the arrival of the animal vaccine and creation of the Municipal Vaccine Institute--a private initative by physician Pedro Affonso Franco, also known as the barao de Pedro Affonso. Adoption of the animal vaccine not only represented progress in controlling the disease but also spurred discussions that saw medical and political groups in Brazil taking sides with either Oswaldo Cruz or the barao de Pedro Affonso. The debate continued within the academic and political arenas until the Vaccine Institute was made part of the Manguinhos laboratories.

  12. A comprehensive system for dosimetric commissioning and Monte Carlo validation for the small animal radiation research platform.

    Science.gov (United States)

    Tryggestad, E; Armour, M; Iordachita, I; Verhaegen, F; Wong, J W

    2009-09-07

    Our group has constructed the small animal radiation research platform (SARRP) for delivering focal, kilo-voltage radiation to targets in small animals under robotic control using cone-beam CT guidance. The present work was undertaken to support the SARRP's treatment planning capabilities. We have devised a comprehensive system for characterizing the radiation dosimetry in water for the SARRP and have developed a Monte Carlo dose engine with the intent of reproducing these measured results. We find that the SARRP provides sufficient therapeutic dose rates ranging from 102 to 228 cGy min(-1) at 1 cm depth for the available set of high-precision beams ranging from 0.5 to 5 mm in size. In terms of depth-dose, the mean of the absolute percentage differences between the Monte Carlo calculations and measurement is 3.4% over the full range of sampled depths spanning 0.5-7.2 cm for the 3 and 5 mm beams. The measured and computed profiles for these beams agree well overall; of note, good agreement is observed in the profile tails. Especially for the smallest 0.5 and 1 mm beams, including a more realistic description of the effective x-ray source into the Monte Carlo model may be important.

  13. A comprehensive system for dosimetric commissioning and Monte Carlo validation for the small animal radiation research platform

    Energy Technology Data Exchange (ETDEWEB)

    Tryggestad, E; Armour, M; Wong, J W [Deptartment of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, MD (United States); Iordachita, I [Laboratory for Computational Sensing and Robotics, Johns Hopkins University, Baltimore, MD (United States); Verhaegen, F [Department of Radiation Oncology (MAASTRO Physics), GROW School, Maastricht University Medical Center, Maastricht (Netherlands)

    2009-09-07

    Our group has constructed the small animal radiation research platform (SARRP) for delivering focal, kilo-voltage radiation to targets in small animals under robotic control using cone-beam CT guidance. The present work was undertaken to support the SARRP's treatment planning capabilities. We have devised a comprehensive system for characterizing the radiation dosimetry in water for the SARRP and have developed a Monte Carlo dose engine with the intent of reproducing these measured results. We find that the SARRP provides sufficient therapeutic dose rates ranging from 102 to 228 cGy min{sup -1} at 1 cm depth for the available set of high-precision beams ranging from 0.5 to 5 mm in size. In terms of depth-dose, the mean of the absolute percentage differences between the Monte Carlo calculations and measurement is 3.4% over the full range of sampled depths spanning 0.5-7.2 cm for the 3 and 5 mm beams. The measured and computed profiles for these beams agree well overall; of note, good agreement is observed in the profile tails. Especially for the smallest 0.5 and 1 mm beams, including a more realistic description of the effective x-ray source into the Monte Carlo model may be important.

  14. Production and Use of Short-Lived Radioisotopes from Reactors. Vol. II. Proceedings of a Seminar on the Practical Applications of Short-Lived Radioisotopes Produced in Small Research Reactors

    International Nuclear Information System (INIS)

    1963-01-01

    There are many radioisotope applications in which it is important that the radiation should rapidly fall to an insignificant level once the initial intense activity has served its purpose. Such applications include diagnostic tests in medicine, where it is essential to reduce the radiation dose to the patient to a minimum, non-destructive testing methods which must be applied without contaminating the material or product concerned, and repeated routine tests which are possible only if the residual activity from the previous test is negligible. All these applications call for radionuclides whose half- lives are measured in hours or even minutes. Similarly, in the new but increasingly important technique of activation analysis, whereby the quantities of elements present in a material can be determined by irradiating the material in a reactor and assaying the radionuclides produced, the latter are mainly short-lived and must be measured immediately. While the production of long-lived radionuclides can most economically be left to the large reactors at the main radioisotope centres, short-lived isotopes must be produced, or materials activation performed, in a reactor at or near the place of intended use or analysis; this, then, represents one of the most important uses for the large number of small reactors which have been installed in recent years, or will come into operation in the near future, in many parts of the world. Since in many countries the new problems of producing, separating and applying short-lived radioisotopes are being faced for the first time, the International Atomic Energy Agency believed it would be valuable to survey the state of the art by convening an international Seminar on Practical Applications of Short-lived Radioisotopes produced in Small Research Reactors at its Vienna headquarters in November, 1962. This Seminar provided an opportunity for the producers and users of short-lived radioisotopes from many countries to meet and discuss the

  15. Production and Use of Short-Lived Radioisotopes from Reactors. Vol. II. Proceedings of a Seminar on the Practical Applications of Short-Lived Radioisotopes Produced in Small Research Reactors

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1963-03-15

    There are many radioisotope applications in which it is important that the radiation should rapidly fall to an insignificant level once the initial intense activity has served its purpose. Such applications include diagnostic tests in medicine, where it is essential to reduce the radiation dose to the patient to a minimum, non-destructive testing methods which must be applied without contaminating the material or product concerned, and repeated routine tests which are possible only if the residual activity from the previous test is negligible. All these applications call for radionuclides whose half- lives are measured in hours or even minutes. Similarly, in the new but increasingly important technique of activation analysis, whereby the quantities of elements present in a material can be determined by irradiating the material in a reactor and assaying the radionuclides produced, the latter are mainly short-lived and must be measured immediately. While the production of long-lived radionuclides can most economically be left to the large reactors at the main radioisotope centres, short-lived isotopes must be produced, or materials activation performed, in a reactor at or near the place of intended use or analysis; this, then, represents one of the most important uses for the large number of small reactors which have been installed in recent years, or will come into operation in the near future, in many parts of the world. Since in many countries the new problems of producing, separating and applying short-lived radioisotopes are being faced for the first time, the International Atomic Energy Agency believed it would be valuable to survey the state of the art by convening an international Seminar on Practical Applications of Short-lived Radioisotopes produced in Small Research Reactors at its Vienna headquarters in November, 1962. This Seminar provided an opportunity for the producers and users of short-lived radioisotopes from many countries to meet and discuss the

  16. Endoscopic Cerenkov luminescence imaging: in vivo small animal tumor model validation

    Science.gov (United States)

    Song, Tianming; Bao, Chengpeng; Hu, Zhenhua; Wang, Kun; Liu, Xia; Tian, Jie

    2015-03-01

    Background: Cerenkov luminescence imaging (CLI) provides a great potential for clinical translation of optical molecular imaging techniques through using clinical approved radiotracers. However, it is difficult to obtain the Cerenkov luminescence signal of deeper biological tissues due to the small magnitude of the signal. To efficiently acquire the weak Cerenkov luminescence, we developed an endoscopic Cerenkov luminescence imaging (ECLI) system to reduce the in vivo imaging depth with minimum invasion, and validated the system on small animal tumor models. Methods: For the ECLI system, the laparoscope was connected to a high sensitive charge-couple device (CCD) camera (DU888+, Andor, UK) by a custom made adapter. We conducted a series of in vitro and in vivo experiments by use of the system. In the in vitro experiment, the endoscopic luminescence images of the 18F-FDG with various activities in EP tubes were acquired using ECLI system, and the sensitivity was compared with conventional CLI system. In the in vivo tumor experiment, 18F-FDG with the activity of 200μCi were intravenously injected into 3 tumor mice. Then the ECLI system was used to acquire the optical images for both non-invasive and invasive conditions. Conclusion: Experimental data showed the ECLI system could detect the 18F-FDG with the activity as low as 1μCi. Furthermore, our preliminary results indicated the possibility of ECLI technique for detecting Cerenkov signals inside the tumor tissue with deeper depth and guiding the surgical operation of tumor excision. We believe that this technique can help to accelerate the clinical translation of CLI.

  17. 9 CFR 3.14 - Primary enclosures used to transport live dogs and cats.

    Science.gov (United States)

    2010-01-01

    ... live dogs and cats. 3.14 Section 3.14 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION..., Treatment, and Transportation of Dogs and Cats 1 Transportation Standards § 3.14 Primary enclosures used to transport live dogs and cats. Any person subject to the Animal Welfare regulations (9 CFR parts 1, 2, and 3...

  18. Sinography in the investigation of draining tracts in small animals: retrospective review of 25 cases

    International Nuclear Information System (INIS)

    Lamb, C.R.; White, R.N.; McEvoy, F.J.

    1994-01-01

    The signalment, history, clinical signs, radiographic findings, and surgical findings of 25 consecutive animals that had sinography were reviewed to assess the contribution made by sinography to diagnosing and surgically managing draining tracts in small animals. There were 23 dogs and 2 cats; a variety of breeds and both sexes were represented (18 males, 7 females). Before referral the mean duration of clinical signs was 9.8 months (range, 0.5 to 33 months) and a mean of 2.0 surgical procedures (range, 1 to 5) had been performed. Sinuses occurred in a variety of locations, most commonly the neck (10), head (6), and paws (5). The most common cause was foreign body (15). Survey radiographs showed abnormalities in 21 of 26 (78%) instances, including soft-tissue swelling (11), chronic-appearing periosteal reaction on adjacent bones (5), possible foreign body (4), and gas in soft tissues (2). Sinography (or fistulography) enabled definite diagnosis of the cause of the sinus (or fistula) in 15 of 26 (58%) instances and demonstrated 13 of 15 foreign bodies (sensitivity 87%; specificity 100%). Tracts caused by an esophageal perforation and otitis media were also correctly shown by fistulography. In 11 animals, sinography indicated that the position or extent of the lesion was different to that expected on the basis of clinical signs and survey radiographs

  19. Real-time bladder volume monitoring by the application of a new implantable bladder volume sensor for a small animal model

    Directory of Open Access Journals (Sweden)

    Dong Sup Lee

    2011-04-01

    Full Text Available Although real-time monitoring of bladder volume together with intravesical pressure can provide more information for understanding the functional changes of the urinary bladder, it still entails difficulties in the accurate prediction of real-time bladder volume in urodynamic studies with small animal models. We studied a new implantable bladder volume monitoring device with eight rats. During cystometry, microelectrodes prepared by the microelectromechanical systems process were placed symmetrically on both lateral walls of the bladder, and the expanded bladder volume was calculated. Immunohistological study was done after 1 week and after 4 weeks to evaluate the biocompatibility of the microelectrode. From the point that infused saline volume into the bladder was higher than 0.6 mL, estimated bladder volume was statistically correlated with the volume of saline injected (p<0.01. Additionally, the microelectromechanical system microelectrodes used in this study showed reliable biocompatibility. Therefore, the device can be used to evaluate changes in bladder volume in studies with small animals, and it may help to provide more information about functional changes in the bladder in laboratory studies. Furthermore, owing to its biocompatibility, the device could be chronically implanted in conscious ambulating animals, thus allowing a novel longitudinal study to be performed for a specific purpose.

  20. 9 CFR 93.905 - Declaration and other documents for live fish, fertilized eggs, and gametes.

    Science.gov (United States)

    2010-01-01

    ... live fish, fertilized eggs, and gametes. 93.905 Section 93.905 Animals and Animal Products ANIMAL AND... for live fish, fertilized eggs, and gametes. (a) For all live fish, fertilized eggs, and gametes... fish, fertilized eggs, or gametes, the number, species, and the purpose of the importation, the name of...

  1. Correction of MRI-induced geometric distortions in whole-body small animal PET-MRI

    International Nuclear Information System (INIS)

    Frohwein, Lynn J.; Schäfers, Klaus P.; Hoerr, Verena; Faber, Cornelius

    2015-01-01

    Purpose: The fusion of positron emission tomography (PET) and magnetic resonance imaging (MRI) data can be a challenging task in whole-body PET-MRI. The quality of the registration between these two modalities in large field-of-views (FOV) is often degraded by geometric distortions of the MRI data. The distortions at the edges of large FOVs mainly originate from MRI gradient nonlinearities. This work describes a method to measure and correct for these kind of geometric distortions in small animal MRI scanners to improve the registration accuracy of PET and MRI data. Methods: The authors have developed a geometric phantom which allows the measurement of geometric distortions in all spatial axes via control points. These control points are detected semiautomatically in both PET and MRI data with a subpixel accuracy. The spatial transformation between PET and MRI data is determined with these control points via 3D thin-plate splines (3D TPS). The transformation derived from the 3D TPS is finally applied to real MRI mouse data, which were acquired with the same scan parameters used in the phantom data acquisitions. Additionally, the influence of the phantom material on the homogeneity of the magnetic field is determined via field mapping. Results: The spatial shift according to the magnetic field homogeneity caused by the phantom material was determined to a mean of 0.1 mm. The results of the correction show that distortion with a maximum error of 4 mm could be reduced to less than 1 mm with the proposed correction method. Furthermore, the control point-based registration of PET and MRI data showed improved congruence after correction. Conclusions: The developed phantom has been shown to have no considerable negative effect on the homogeneity of the magnetic field. The proposed method yields an appropriate correction of the measured MRI distortion and is able to improve the PET and MRI registration. Furthermore, the method is applicable to whole-body small animal

  2. Correction of MRI-induced geometric distortions in whole-body small animal PET-MRI

    Energy Technology Data Exchange (ETDEWEB)

    Frohwein, Lynn J., E-mail: frohwein@uni-muenster.de; Schäfers, Klaus P. [European Institute for Molecular Imaging, University of Münster, Münster 48149 (Germany); Hoerr, Verena; Faber, Cornelius [Department of Clinical Radiology, University Hospital of Münster, Münster 48149 (Germany)

    2015-07-15

    Purpose: The fusion of positron emission tomography (PET) and magnetic resonance imaging (MRI) data can be a challenging task in whole-body PET-MRI. The quality of the registration between these two modalities in large field-of-views (FOV) is often degraded by geometric distortions of the MRI data. The distortions at the edges of large FOVs mainly originate from MRI gradient nonlinearities. This work describes a method to measure and correct for these kind of geometric distortions in small animal MRI scanners to improve the registration accuracy of PET and MRI data. Methods: The authors have developed a geometric phantom which allows the measurement of geometric distortions in all spatial axes via control points. These control points are detected semiautomatically in both PET and MRI data with a subpixel accuracy. The spatial transformation between PET and MRI data is determined with these control points via 3D thin-plate splines (3D TPS). The transformation derived from the 3D TPS is finally applied to real MRI mouse data, which were acquired with the same scan parameters used in the phantom data acquisitions. Additionally, the influence of the phantom material on the homogeneity of the magnetic field is determined via field mapping. Results: The spatial shift according to the magnetic field homogeneity caused by the phantom material was determined to a mean of 0.1 mm. The results of the correction show that distortion with a maximum error of 4 mm could be reduced to less than 1 mm with the proposed correction method. Furthermore, the control point-based registration of PET and MRI data showed improved congruence after correction. Conclusions: The developed phantom has been shown to have no considerable negative effect on the homogeneity of the magnetic field. The proposed method yields an appropriate correction of the measured MRI distortion and is able to improve the PET and MRI registration. Furthermore, the method is applicable to whole-body small animal

  3. Instruments for radiation measurement in life sciences (5), ''Development of imaging technology in life sciences'' III. Development of small animal PET scanners

    International Nuclear Information System (INIS)

    Yamaya, Taiga; Murayama, Hideo

    2006-01-01

    This paper summarizes the requisites for small animal PET scanners, present state of their market and of their development in National Institute of Radiological Sciences (NIRS). Relative to the apparatus clinically used, the requisites involve the high spatial resolution of 0.8-1.5 mm and high sensitivity of the equipment itself due to low dose of the tracer to be given to animals. At present, more than 20 institutions like universities, research facilities and companies are developing the PET equipment for small animals and about 10 machines are in the market. However, their resolution and sensitivity are not fully satisfactory and for their improvement, investigators are paying attention to the gamma ray measurement by depth-of-interaction (DOI) method. NIRS has been also developing the machine jPET-D4 and has proposed to manufacture jPET-RD having 4-layer DOI detectors with the absolute central sensitivity as high as 14.7%. jPET-RD is to have the spatial resolution as high as <1mm (central view) and -1.4 mm (periphery). (T.I.)

  4. 9 CFR 3.36 - Primary enclosures used to transport live guinea pigs and hamsters.

    Science.gov (United States)

    2010-01-01

    ... live guinea pigs and hamsters. 3.36 Section 3.36 Animals and Animal Products ANIMAL AND PLANT HEALTH..., Care, Treatment, and Transportation of Guinea Pigs and Hamsters Transportation Standards § 3.36 Primary enclosures used to transport live guinea pigs and hamsters. No person subject to the Animal Welfare...

  5. Animal computer interaction (ACI) & designing for animal interaction (AXD)

    DEFF Research Database (Denmark)

    Morrison, Ann Judith; Turner, Jane; Farley, Helen

    2017-01-01

    This workshop invites researchers and practitioners from HCI and related fields who work in some capacity with animals and who recognise the sentient nature of their being. We call for those who want to better understand how to work with animals and learn from them. We are a small team looking...... to build an Australian chapter of the Animal Computer Interaction Community. The workshop will elicit discussion, forge new partnerships and head up a new group on the state of the art within this field in Australia, including comparative international studies. For more information see http://www.ozaci.org/...

  6. SiliPET: Design of an ultra-high resolution small animal PET scanner based on stacks of semi-conductor detectors

    International Nuclear Information System (INIS)

    Cesca, N.; Auricchio, N.; Di Domenico, G.; Zavattini, G.; Malaguti, R.; Andritschke, R.; Kanbach, G.; Schopper, F.

    2007-01-01

    We studied with Monte Carlo simulations, using the EGSnrc code, a new scanner for small animal positron emission tomography (PET), based on stacks of double-sided semiconductor detectors. Each stack is composed of planar detectors with dimension 70x60x1 mm 3 and orthogonal strips on both sides with 500 μm pitch to read the two interaction coordinates, the third being the detector number in the stack. Multiple interactions in a stack are discarded. In this way, we achieve a precise determination of the first interaction point of the two 511 keV photons. The reduced dimensions of the scanner also improve the solid angle coverage resulting in a high sensitivity. Preliminary results of scanners based on Si planar detectors are presented and the initial tomographic reconstructions demonstrate very good spatial resolution limited only by the positron range. This suggests that, this is a promising new approach for small animal PET imaging. We are testing some double-sided silicon detectors, equipped with 128 orthogonal p and n strips on opposite sides using VATAGP3 ASIC by IDEAS

  7. Use of scanner characteristics in iterative image reconstruction for high-resolution positron emission tomography studies of small animals

    Energy Technology Data Exchange (ETDEWEB)

    Brix, G. [Research Program ``Radiological Diagnostics and Therapy``, German Cancer Research Center (DKFZ), Heidelberg (Germany); Doll, J. [Research Program ``Radiological Diagnostics and Therapy``, German Cancer Research Center (DKFZ), Heidelberg (Germany); Bellemann, M.E. [Research Program ``Radiological Diagnostics and Therapy``, German Cancer Research Center (DKFZ), Heidelberg (Germany); Trojan, H. [Research Program ``Radiological Diagnostics and Therapy``, German Cancer Research Center (DKFZ), Heidelberg (Germany); Haberkorn, U. [Research Program ``Radiological Diagnostics and Therapy``, German Cancer Research Center (DKFZ), Heidelberg (Germany); Schmidlin, P. [Research Program ``Radiological Diagnostics and Therapy``, German Cancer Research Center (DKFZ), Heidelberg (Germany); Ostertag, H. [Research Program ``Radiological Diagnostics and Therapy``, German Cancer Research Center (DKFZ), Heidelberg (Germany)

    1997-07-01

    The purpose of this work was to improve of the spatial resolution of a whole-body PET system for experimental studies of small animals by incorporation of scanner characteristics into the process of iterative image reconstruction. The image-forming characteristics of the PET camera were characterized by a spatially variant line-spread function (LSF), which was determined from 49 activated copper-64 line sources positioned over a field of view (FOV) of 21.0 cm. During the course of iterative image reconstruction, the forward projection of the estimated image was blurred with the LSF at each iteration step before the estimated projections were compared with the measured projections. Moreover, imaging studies of a rat and two nude mice were performed to evaluate the imaging properties of our approach in vivo. The spatial resolution of the scanner perpendicular to the direction of projection could be approximated by a one-dimensional Gaussian-shaped LSF with a full-width at half-maximum increasing from 6.5 mm at the centre to 6.7 mm at a radial distance of 10.5 cm. The incorporation of this blurring kernel into the iteration formula resulted in a significantly improved spatial resolution of about 3.9 mm over the examined FOV. As demonstrated by the phantom and the animal experiments, the high-resolution algorithm not only led to a better contrast resolution in the reconstructed emission scans but also improved the accuracy for quantitating activity concentrations in small tissue structures without leading to an amplification of image noise or image mottle. The presented data-handling strategy incorporates the image restoration step directly into the process of algebraic image reconstruction and obviates the need for ill-conditioned ``deconvolution`` procedures to be performed on the projections or on the reconstructed image. In our experience, the proposed algorithm is of special interest in experimental studies of small animals. (orig./AJ). With 9 figs.

  8. Use of scanner characteristics in iterative image reconstruction for high-resolution positron emission tomography studies of small animals

    International Nuclear Information System (INIS)

    Brix, G.; Doll, J.; Bellemann, M.E.; Trojan, H.; Haberkorn, U.; Schmidlin, P.; Ostertag, H.

    1997-01-01

    The purpose of this work was to improve of the spatial resolution of a whole-body PET system for experimental studies of small animals by incorporation of scanner characteristics into the process of iterative image reconstruction. The image-forming characteristics of the PET camera were characterized by a spatially variant line-spread function (LSF), which was determined from 49 activated copper-64 line sources positioned over a field of view (FOV) of 21.0 cm. During the course of iterative image reconstruction, the forward projection of the estimated image was blurred with the LSF at each iteration step before the estimated projections were compared with the measured projections. Moreover, imaging studies of a rat and two nude mice were performed to evaluate the imaging properties of our approach in vivo. The spatial resolution of the scanner perpendicular to the direction of projection could be approximated by a one-dimensional Gaussian-shaped LSF with a full-width at half-maximum increasing from 6.5 mm at the centre to 6.7 mm at a radial distance of 10.5 cm. The incorporation of this blurring kernel into the iteration formula resulted in a significantly improved spatial resolution of about 3.9 mm over the examined FOV. As demonstrated by the phantom and the animal experiments, the high-resolution algorithm not only led to a better contrast resolution in the reconstructed emission scans but also improved the accuracy for quantitating activity concentrations in small tissue structures without leading to an amplification of image noise or image mottle. The presented data-handling strategy incorporates the image restoration step directly into the process of algebraic image reconstruction and obviates the need for ill-conditioned ''deconvolution'' procedures to be performed on the projections or on the reconstructed image. In our experience, the proposed algorithm is of special interest in experimental studies of small animals. (orig./AJ). With 9 figs

  9. A. Femoralis in the small Green Monkey(Cercopithecus aethiops sabeus

    Directory of Open Access Journals (Sweden)

    Blagojević Miloš

    2016-01-01

    Full Text Available The small Green Monkey (Cercopithecus aethiops sabeus in large groups inhabits the African savannah. The animals delivered to us were from East Africa, that is from Kenya, Uganda and Tanzania. The length of the animal is 110 cm, and the tail itself is 50 cm long. They can often be seen in Zoos. According to data, mostly by zoo gardens, these monkeys live for about 15 to 17 years, exceptionally for 20 years. The objective of our work was to investigate a part of their cardiovascular system so in that way to contribute to a better knowledge of this animal body structure and accordingly to comparative anatomy in general. The investigation included 6 Small Green Monkeys, of both gender, 3-4 years old, body weight 2000-3000 grams, obtained from The Institute for Virusology, vaccines and serums from Belgrade. For obtaining the hindlimb arterial vascularization, after exsanguination of the animal, contrast mass of gelatin coloured with tempera was injected into the abdominal aorta. After injecting, the blood vessels were prepared and photographed. In the Small Green Monkey, femoral artery (A. femoralis is an continuation of the external iliac artery (A. iliaca externa. The branches of the femoral artery are: A. profunda femoris, A. saphena, A. genus descendens and A. caudalis femoralis. A. profunda femoris separates to A. circumflexa femoris lateralis, Ramus muscularis and A. circumflexa femoris medialis. In humans A. femoralis branches into: A. epigastrica superficialis, A. circumflexa ilium superficialis, Aa. pudendae externae, A. profunda femoris and A. genus descendens (A. descendens genus. A. profunda femoris branches into: A. circumflexa femoris lateralis, A. circumflexa femoris medialis and Aa. perforantes. In domestic animals, mammals, the branches of the femoral artery (A. femoralis are: A. circumflexa femoris lateralis, A. saphena, A. genus descendens and Aa. caudales femoris In the Small Green Monkey, humans and domestic mammals A. femoralis

  10. Animals

    Energy Technology Data Exchange (ETDEWEB)

    Skuterud, L.; Strand, P. [Norwegian Radiation Protection Authority (Norway); Howard, B.J. [Inst. of Terrestrial Ecology (United Kingdom)

    1997-10-01

    The radionuclides of most concern with respect to contamination of animals after a nuclear accident are radioiodine, radiocaesium and radiostrontium (ICRP 30, 1979). Of the other significant anthropogenic radionuclides likely to be released in most accidents, only small proportions of that ingested will be absorbed in an animals gut, and the main animal products, milk and meat, will not normally be contaminated to a significant extent. Animal products will mostly be contaminated as a result of ingestion of contaminated feed and possibly, but to a much lesser extent, from inhalation (for radioiodine only). Direct external contamination of animals is of little or no consequence in human food production. Radioiodine and radiostrontium are important with respect to contamination of milk; radiocaesium contaminates both milk and meat. The physical and chemical form of a radionuclide can influence its absorption in the animal gut. For example, following the Chernobyl accident radiocaesium incorporated into vegetation by root uptake was more readily absorbed than that associated with the original deposit. The transfer of radiocaesium and radiostrontium to animals will be presented both as transfer coefficients and aggregated transfer coefficients. For most animal meat products, only radiocaesium is important as other radionuclides do not significantly contaminate muscle. Farm animal products are the most important foodstuff determining radiocaesium intake by the average consumer in the Nordic countries. The major potential source of radioiodine and radiostrontium to humans is milk and milk products. Of the different species, the smaller animals have the highest transfer of radiocaesium from fodder to meat and milk. (EG). 68 refs.

  11. Animals

    International Nuclear Information System (INIS)

    Skuterud, L.; Strand, P.; Howard, B.J.

    1997-01-01

    The radionuclides of most concern with respect to contamination of animals after a nuclear accident are radioiodine, radiocaesium and radiostrontium (ICRP 30, 1979). Of the other significant anthropogenic radionuclides likely to be released in most accidents, only small proportions of that ingested will be absorbed in an animals gut, and the main animal products, milk and meat, will not normally be contaminated to a significant extent. Animal products will mostly be contaminated as a result of ingestion of contaminated feed and possibly, but to a much lesser extent, from inhalation (for radioiodine only). Direct external contamination of animals is of little or no consequence in human food production. Radioiodine and radiostrontium are important with respect to contamination of milk; radiocaesium contaminates both milk and meat. The physical and chemical form of a radionuclide can influence its absorption in the animal gut. For example, following the Chernobyl accident radiocaesium incorporated into vegetation by root uptake was more readily absorbed than that associated with the original deposit. The transfer of radiocaesium and radiostrontium to animals will be presented both as transfer coefficients and aggregated transfer coefficients. For most animal meat products, only radiocaesium is important as other radionuclides do not significantly contaminate muscle. Farm animal products are the most important foodstuff determining radiocaesium intake by the average consumer in the Nordic countries. The major potential source of radioiodine and radiostrontium to humans is milk and milk products. Of the different species, the smaller animals have the highest transfer of radiocaesium from fodder to meat and milk. (EG)

  12. MOSFET assessment of radiation dose delivered to mice using the Small Animal Radiation Research Platform (SARRP).

    Science.gov (United States)

    Ngwa, Wilfred; Korideck, Houari; Chin, Lee M; Makrigiorgos, G Mike; Berbeco, Ross I

    2011-12-01

    The Small Animal Radiation Research Platform (SARRP) is a novel isocentric irradiation system that enables state-of-the-art image-guided radiotherapy research to be performed with animal models. This paper reports the results obtained from investigations assessing the radiation dose delivered by the SARRP to different anatomical target volumes in mice. Surgically implanted metal oxide semiconductor field effect transistors (MOSFET) dosimeters were employed for the dose assessment. The results reveal differences between the calculated and measured dose of -3.5 to 0.5%, -5.2 to -0.7%, -3.9 to 0.5%, -5.9 to 2.5%, -5.5 to 0.5%, and -4.3 to 0% for the left kidney, liver, pancreas, prostate, left lung, and brain, respectively. Overall, the findings show less than 6% difference between the delivered and calculated dose, without tissue heterogeneity corrections. These results provide a useful assessment of the need for tissue heterogeneity corrections in SARRP dose calculations for clinically relevant tumor model sites.

  13. The relationship of live animal muscular and skeletal scores, ultrasound measurements and carcass classification scores with carcass composition and value in steers.

    Science.gov (United States)

    Conroy, S B; Drennan, M J; Kenny, D A; McGee, M

    2009-11-01

    This study examined the relationship of muscular and skeletal scores and ultrasound measurements in the live animal, and carcass conformation and fat scores with carcass composition and value using 336 steers, slaughtered at 2 years of age. Live animal scores and measurements were recorded at 8 to 12 months of age and pre-slaughter. Following slaughter, each carcass was classified for conformation and fatness and the right side dissected into meat, fat and bone. Carcass conformation scores and fat scores were both measured on a continuous 15-point scale and ranged from 2.0 to 12.0 and from 2.8 to 13.3, respectively. Pre-slaughter muscular scores showed positive correlations (P carcass meat proportion, proportion of high-value cuts in the carcass, conformation score and carcass value, significant negative correlations with carcass fat (r = -0.13) and bone (r = -0.81) proportions, and generally low non-significant relationships with the proportion of high-value cuts in meat and carcass fat score. Pre-slaughter ultrasound muscle depth and carcass conformation score showed similar correlations with carcass traits to those using the pre-slaughter muscular scoring procedure. Pre-slaughter ultrasound fat depth showed positive correlations (P carcass fat proportion (r = 0.59) and fat score (r = 0.63), and significant negative correlations (-0.23 to -0.50) with carcass meat and bone proportions, high-value cuts in the carcass and in meat, and carcass value. Pre-slaughter skeletal scores generally showed poor correlations ranging from -0.38 to 0.52 with the various carcass traits. Corresponding correlations (-0.26 to 0.44) involving records collected at 8 to 12 months of age were lower than those using pre-slaughter records. A one-unit increase in carcass conformation score increased carcass meat proportion and value by 11.2 g/kg and 5.6 cents/kg, respectively. Corresponding values for fat score were -8.2 g/kg and -5.1 cents/kg. In conclusion, both pre-slaughter live animal

  14. 'More than a feeling': An empirical investigation of hedonistic accounts of animal welfare.

    Science.gov (United States)

    Robbins, Jesse; Franks, Becca; von Keyserlingk, Marina A G

    2018-01-01

    Many scientists studying animal welfare appear to hold a hedonistic concept of welfare -whereby welfare is ultimately reducible to an animal's subjective experience. The substantial advances in assessing animal's subjective experience have enabled us to take a step back to consider whether such indicators are all one needs to know if one is interested in the welfare of an individual. To investigate this claim, we randomly assigned participants (n = 502) to read one of four vignettes describing a hypothetical chimpanzee and asked them to make judgments about the animal's welfare. Vignettes were designed to systematically manipulate the descriptive mental states the chimpanzee was described as experiencing: feels good (FG) vs. feels bad (FB); as well as non-subjective features of the animal's life: natural living and physical healthy (NH) vs. unnatural life and physically unhealthy (UU); creating a fully-crossed 2 (subjective experience) X 2 (objective life value) experimental design. Multiple regression analysis showed welfare judgments depended on the objective features of the animal's life more than they did on how the animal was feeling: a chimpanzee living a natural life with negative emotions was rated as having better welfare than a chimpanzee living an unnatural life with positive emotions. We also found that the supposedly more purely psychological concept of happiness was also influenced by normative judgments about the animal's life. For chimpanzees with positive emotions, those living a more natural life were rated as happier than those living an unnatural life. Insofar as analyses of animal welfare are assumed to be reflective of folk intuitions, these findings raise questions about a strict hedonistic account of animal welfare. More generally, this research demonstrates the potential utility of using empirical methods to address conceptual problems in animal welfare and ethics.

  15. Live-cell microscopy reveals small molecule inhibitor effects on MAPK pathway dynamics.

    Directory of Open Access Journals (Sweden)

    Daniel J Anderson

    Full Text Available Oncogenic mutations in the mitogen activated protein kinase (MAPK pathway are prevalent in human tumors, making this pathway a target of drug development efforts. Recently, ATP-competitive Raf inhibitors were shown to cause MAPK pathway activation via Raf kinase priming in wild-type BRaf cells and tumors, highlighting the need for a thorough understanding of signaling in the context of small molecule kinase inhibitors. Here, we present critical improvements in cell-line engineering and image analysis coupled with automated image acquisition that allow for the simultaneous identification of cellular localization of multiple MAPK pathway components (KRas, CRaf, Mek1 and Erk2. We use these assays in a systematic study of the effect of small molecule inhibitors across the MAPK cascade either as single agents or in combination. Both Raf inhibitor priming as well as the release from negative feedback induced by Mek and Erk inhibitors cause translocation of CRaf to the plasma membrane via mechanisms that are additive in pathway activation. Analysis of Erk activation and sub-cellular localization upon inhibitor treatments reveals differential inhibition and activation with the Raf inhibitors AZD628 and GDC0879 respectively. Since both single agent and combination studies of Raf and Mek inhibitors are currently in the clinic, our assays provide valuable insight into their effects on MAPK signaling in live cells.

  16. High Throughput Screen for Novel Antimicrobials using a Whole Animal Infection Model

    Science.gov (United States)

    Moy, Terence I.; Conery, Annie L.; Larkins-Ford, Jonah; Wu, Gang; Mazitschek, Ralph; Casadei, Gabriele; Lewis, Kim; Carpenter, Anne E.; Ausubel, Frederick M.

    2009-01-01

    The nematode Caenorhabditis elegans is a unique whole animal model system for identifying small molecules with in vivo anti-infective properties. C. elegans can be infected with a broad range of human pathogens, including Enterococcus faecalis, an important human nosocomial pathogen with a mortality rate of up to 37% that is increasingly acquiring resistance to antibiotics. Here, we describe an automated, high throughput screen of 37,200 compounds and natural product extracts for those that enhance survival of C. elegans infected with E. faecalis. The screen uses a robot to accurately dispense live, infected animals into 384-well plates, and automated microscopy and image analysis to generate quantitative, high content data. We identified 28 compounds and extracts that were not previously reported to have antimicrobial properties, including 6 structural classes that cure infected C. elegans animals but do not affect the growth of the pathogen in vitro, thus acting by a mechanism of action distinct from antibiotics currently in clinical use. Our versatile and robust screening system can be easily adapted for other whole animal assays to probe a broad range of biological processes. PMID:19572548

  17. Molecular imaging of drug-modulated protein-protein interactions in living subjects.

    Science.gov (United States)

    Paulmurugan, Ramasamy; Massoud, Tarik F; Huang, Jing; Gambhir, Sanjiv S

    2004-03-15

    Networks of protein interactions mediate cellular responses to environmental stimuli and direct the execution of many different cellular functional pathways. Small molecules synthesized within cells or recruited from the external environment mediate many protein interactions. The study of small molecule-mediated interactions of proteins is important to understand abnormal signal transduction pathways in cancer and in drug development and validation. In this study, we used split synthetic renilla luciferase (hRLUC) protein fragment-assisted complementation to evaluate heterodimerization of the human proteins FRB and FKBP12 mediated by the small molecule rapamycin. The concentration of rapamycin required for efficient dimerization and that of its competitive binder ascomycin required for dimerization inhibition were studied in cell lines. The system was dually modulated in cell culture at the transcription level, by controlling nuclear factor kappaB promoter/enhancer elements using tumor necrosis factor alpha, and at the interaction level, by controlling the concentration of the dimerizer rapamycin. The rapamycin-mediated dimerization of FRB and FKBP12 also was studied in living mice by locating, quantifying, and timing the hRLUC complementation-based bioluminescence imaging signal using a cooled charged coupled device camera. This split reporter system can be used to efficiently screen small molecule drugs that modulate protein-protein interactions and also to assess drugs in living animals. Both are essential steps in the preclinical evaluation of candidate pharmaceutical agents targeting protein-protein interactions, including signaling pathways in cancer cells.

  18. 9 CFR 93.902 - Ports designated for the importation of live fish, fertilized eggs, and gametes.

    Science.gov (United States)

    2010-01-01

    ... of live fish, fertilized eggs, and gametes. 93.902 Section 93.902 Animals and Animal Products ANIMAL... importation of live fish, fertilized eggs, and gametes. (a) The following ports are designated as ports of entry for live fish, fertilized eggs, and gametes of SVC-susceptible species imported under this subpart...

  19. 9 CFR 93.903 - Import permits for live fish, fertilized eggs, and gametes.

    Science.gov (United States)

    2010-01-01

    ..., fertilized eggs, and gametes. 93.903 Section 93.903 Animals and Animal Products ANIMAL AND PLANT HEALTH... General Provisions for Svc-Regulated Fish Species § 93.903 Import permits for live fish, fertilized eggs, and gametes. (a) Live fish, fertilized eggs, or gametes of SVC-susceptible species imported into the...

  20. A clinical gamma camera-based pinhole collimated system for high resolution small animal SPECT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Mejia, J.; Galvis-Alonso, O.Y., E-mail: mejia_famerp@yahoo.com.b [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil). Dept. de Biologia Molecular; Castro, A.A. de; Simoes, M.V. [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil). Dept. de Clinica Medica; Leite, J.P. [Universidade de Sao Paulo (FMRP/USP), Ribeirao Preto, SP (Brazil). Fac. de Medicina. Dept. de Neurociencias e Ciencias do Comportamento; Braga, J. [Instituto Nacional de Pesquisas Espaciais (INPE), Sao Jose dos Campos, SP (Brazil). Div. de Astrofisica

    2010-11-15

    The main objective of the present study was to upgrade a clinical gamma camera to obtain high resolution tomographic images of small animal organs. The system is based on a clinical gamma camera to which we have adapted a special-purpose pinhole collimator and a device for positioning and rotating the target based on a computer-controlled step motor. We developed a software tool to reconstruct the target's three-dimensional distribution of emission from a set of planar projections, based on the maximum likelihood algorithm. We present details on the hardware and software implementation. We imaged phantoms and heart and kidneys of rats. When using pinhole collimators, the spatial resolution and sensitivity of the imaging system depend on parameters such as the detector-to-collimator and detector-to-target distances and pinhole diameter. In this study, we reached an object voxel size of 0.6 mm and spatial resolution better than 2.4 and 1.7 mm full width at half maximum when 1.5- and 1.0-mm diameter pinholes were used, respectively. Appropriate sensitivity to study the target of interest was attained in both cases. Additionally, we show that as few as 12 projections are sufficient to attain good quality reconstructions, a result that implies a significant reduction of acquisition time and opens the possibility for radiotracer dynamic studies. In conclusion, a high resolution single photon emission computed tomography (SPECT) system was developed using a commercial clinical gamma camera, allowing the acquisition of detailed volumetric images of small animal organs. This type of system has important implications for research areas such as Cardiology, Neurology or Oncology. (author)

  1. A high resolution small animal radiation research platform (SARRP) with x-ray tomographic guidance capabilities

    Science.gov (United States)

    Wong, John; Armour, Elwood; Kazanzides, Peter; Iordachita, Iulian; Tryggestad, Erik; Deng, Hua; Matinfar, Mohammad; Kennedy, Christopher; Liu, Zejian; Chan, Timothy; Gray, Owen; Verhaegen, Frank; McNutt, Todd; Ford, Eric; DeWeese, Theodore L.

    2008-01-01

    Purpose To demonstrate the CT imaging, conformal irradiation and treatment planning capabilities of a small animal radiation research platform (SARRP). Methods The SARRP employs a dual-focal spot, constant voltage x-ray source mounted on a gantry with a source-to-isocenter distance of 35 cm. Gantry rotation is limited to 120° from vertical. Eighty to 100 kVp x-rays from the smaller 0.4 mm focal spot are used for imaging. Both 0.4 mm and 3.0 mm focal spots operate at 225 kVp for irradiation. Robotic translate/rotate stages are used to position the animal. Cone-beam (CB) CT imaging is achieved by rotating the horizontal animal between the stationary x-ray source and a flat-panel detector. Radiation beams range from 0.5 mm in diameter to (60 × 60) mm2. Dosimetry is measured with radio-chromic films. Monte Carlo dose calculations are employed for treatment planning. The combination of gantry and robotic stage motions facilitate conformal irradiation. Results The SARRP spans 3 ft × 4 ft × 6 ft (WxLxH). Depending on filtration, the isocenter dose outputs at 1 cm depth in water range from 22 to 375 cGy/min from the smallest to the largest radiation fields. The 20% to 80% dose fall-off spans 0.16 mm. CBCT with (0.6 × 0.6 × 0.6) mm3 voxel resolution is acquired with less than 1 cGy. Treatment planning is performed at sub-mm resolution. Conclusions The capability of the SARRP to deliver highly focal beams to multiple animal model systems provides new research opportunities that more realistically bridge laboratory research and clinical translation. PMID:18640502

  2. Tuberculous and tuberculoid lesions in free living small terrestrial mammals and the risk of infection to humans and animals: a review

    Czech Academy of Sciences Publication Activity Database

    Skorič, M.; Shitaye, E. J.; Halouzka, R.; Fictum, P.; Trčka, I.; Heroldová, Marta; Tkadlec, Emil; Pavlík, I.

    2007-01-01

    Roč. 52, č. 4 (2007), s. 144-161 ISSN 0375-8427 R&D Projects: GA ČR GA206/04/2003 Grant - others:MZE(CZ) 1B53009 Program:1B Institutional research plan: CEZ:AV0Z60930519 Keywords : bovine tuberculosis * paratuberculosis * avian tuberculosis * mycobacteriosis * terrestrial mammals * zoonoses Subject RIV: GJ - Animal Vermins ; Diseases, Veterinary Medicine Impact factor: 0.645, year: 2007 http://www.vri.cz/docs/vetmed/52-4-144.pdf

  3. Basic live sound reinforcement a practical guide for starting live audio

    CERN Document Server

    Biederman, Raven

    2013-01-01

    Access and interpret manufacturer spec information, find shortcuts for plotting measure and test equations, and learn how to begin your journey towards becoming a live sound professional. Land and perform your first live sound gigs with this guide that gives you just the right amount of information. Don't get bogged down in details intended for complex and expensive equipment and Madison Square Garden-sized venues. Basic Live Sound Reinforcement is a handbook for audio engineers and live sound enthusiasts performing in small venues from one-mike coffee shops to clubs. With their combined ye

  4. Role of radiotracer in animal science

    International Nuclear Information System (INIS)

    Sivaprasad, N.

    2015-01-01

    Radiotracers have been used as radiopharmaceuticals for diagnosis and treatment of animal diseases in cattle and pet animals. In fact the veterinary nuclear medicine based on radiotracer as radiopharmaceuticals is established medical technique for functional studies and imaging of vital organs such as heart, lung, brain, spleen, liver, kidney etc for diagnosis as well as treatment of diseases such as cancers in animal. Besides, radiation from radioisotopes has been in use for radiation therapy of cancers in animals. The nuclear imaging using positron emitting radiotracer is gaining importance in the evolution of drug in small animals. In this respect, small animals have also contributed significantly in the development of radiopharmaceuticals particularly for biodistribution and bioscan studies. In fact, the quality control of radiopharmaceuticals in animals to test the safety is a mandatory requirement in the production of radiopharmaceuticals. In brief the animal science has contributed in various areas and facets of radiotracer techniques and its application vice versa the radiotracer techniques have contributed towards the progress of animal science. The animal science in combination with radiotracer has also contributed to the progress of other basic and applied sciences. Thus there exists a bond between radiotracer techniques and animal science. Some aspects of mutual dependence of animal science and radiotracer are elaborated

  5. Live animal measurements, carcass composition and plasma hormone and metabolite concentrations in male progeny of sires differing in genetic merit for beef production.

    Science.gov (United States)

    Clarke, A M; Drennan, M J; McGee, M; Kenny, D A; Evans, R D; Berry, D P

    2009-07-01

    In genetic improvement programmes for beef cattle, the effect of selecting for a given trait or index on other economically important traits, or their predictors, must be quantified to ensure no deleterious consequential effects go unnoticed. The objective was to compare live animal measurements, carcass composition and plasma hormone and metabolite concentrations of male progeny of sires selected on an economic index in Ireland. This beef carcass index (BCI) is expressed in euros and based on weaning weight, feed intake, carcass weight and carcass conformation and fat scores. The index is used to aid in the genetic comparison of animals for the expected profitability of their progeny at slaughter. A total of 107 progeny from beef sires of high (n = 11) or low (n = 11) genetic merit for the BCI were compared in either a bull (slaughtered at 16 months of age) or steer (slaughtered at 24 months of age) production system, following purchase after weaning (8 months of age) from commercial beef herds. Data were analysed as a 2 × 2 factorial design (two levels of genetic merit by two production systems). Progeny of high BCI sires had heavier carcasses, greater (P animal value (obtained by multiplying carcass weight by carcass value, which was based on the weight of meat in each cut by its commercial value) than progeny of low BCI sires. Regression of progeny performance on sire genetic merit was also undertaken across the entire data set. In steers, the effect of BCI on carcass meat proportion, calculated carcass value (c/kg) and animal value was positive (P carcass fat proportion (P carcass weight followed the same trends as BCI. Muscularity scores, carcass meat proportion and calculated carcass value increased, whereas scanned fat depth, carcass fat and bone proportions decreased with increasing sire EPD for conformation score. The opposite association was observed for sire EPD for fat score. Results from this study show that selection using the BCI had positive

  6. Energy resolution of a four-layer depth of interaction detector block for small animal PET

    International Nuclear Information System (INIS)

    Tsuda, Tomoaki; Kawai, Hideyuki; Orita, Narimichi; Murayama, Hideo; Yoshida, Eiji; Inadama, Naoko; Yamaya, Taiga; Omura, Tomohide

    2004-01-01

    We are now planning to develop a positron emission tomograph dedicated to small animals such as rats and mice which meets the demand for higher sensitivity. We proposed a new depth of interaction (DOI) detector arrangement to obtain DOI information by using a four-layer detector with all the same crystal elements. In this DOI detector, we control the behavior of scintillation photons by inserting the reflectors between crystal elements so that the DOI information of four layers can be extracted from one two-dimensional (2D) position histogram made by Anger-type calculation. In this work, we evaluate the energy resolution of this four-layer DOI detector. (author)

  7. The application of biotechnology in animal nutrition

    OpenAIRE

    Šefer, Dragan; Marković, Radmila; Nedeljković-Trailović, Jelena; Petrujkić, Branko; Radulović, Stamen; Grdović, Svetlana

    2015-01-01

    Animal food has to incorporate multiple objectives, ie. it should provide good animal health, good production and reproductive performance, reduce pollution of the environment as well as have the impact on food of animal origin, by supplying it, in addition to basic nutrients, with certain useful substances that can act preventively on the occurrence of various diseases in humans in modern living conditions. This complex task implies the application of scie...

  8. Application of photostable quantum dots for indirect immunofluorescent detection of specific bacterial serotypes on small marine animals

    International Nuclear Information System (INIS)

    Decho, Alan W; Beckman, Erin M; Chandler, G Thomas; Kawaguchi, Tomohiro

    2008-01-01

    An indirect immunofluorescence approach was developed using semiconductor quantum dot nanocrystals to label and detect a specific bacterial serotype of the bacterial human pathogen Vibrio parahaemolyticus, attached to small marine animals (i.e. benthic harpacticoid copepods), which are suspected pathogen carriers. This photostable labeling method using nanotechnology will potentially allow specific serotypes of other bacterial pathogens to be detected with high sensitivity in a range of systems, and can be easily applied for sensitive detection to other Vibrio species such as Vibrio cholerae

  9. Animals & Livestock | National Agricultural Library

    Science.gov (United States)

    News Contact Us Search  Log inRegister Home Home Animals & Livestock NEWT: National Extension fisher occupancy of small, 1 km^2^ grid cells of forest habitat. Animals and Livestock html Data from consisting of IL-12Rβ1 and IL-23R, and activates the JAK/STAT signaling pathways. Animals and Livestock html

  10. Animal transportation networks

    Science.gov (United States)

    Perna, Andrea; Latty, Tanya

    2014-01-01

    Many group-living animals construct transportation networks of trails, galleries and burrows by modifying the environment to facilitate faster, safer or more efficient movement. Animal transportation networks can have direct influences on the fitness of individuals, whereas the shape and structure of transportation networks can influence community dynamics by facilitating contacts between different individuals and species. In this review, we discuss three key areas in the study of animal transportation networks: the topological properties of networks, network morphogenesis and growth, and the behaviour of network users. We present a brief primer on elements of network theory, and then discuss the different ways in which animal groups deal with the fundamental trade-off between the competing network properties of travel efficiency, robustness and infrastructure cost. We consider how the behaviour of network users can impact network efficiency, and call for studies that integrate both network topology and user behaviour. We finish with a prospectus for future research. PMID:25165598

  11. Evaluation of spatial sensitivity of a prompt gamma neutron activation analysis facility for the in vivo determination of nitrogen in small animals

    International Nuclear Information System (INIS)

    Kasviki, K.; Ioannina University; Stamatelatos, I.E.; Kalef-Ezra, J.

    2007-01-01

    We investigated the spatial dependence of the sensitivity of nitrogen measurement with a prompt gamma neutron activation analysis (PGNAA) system for small animals and developed an analysis procedure that permits the reduction of systematic errors due to that dependence. The analysis procedure is based on neutron and photon transport calculations performed using the MCNP code in order to evaluate the sensitivity of the PGNAA facility. The system can be calibrated experimentally using a small number of phantoms of known size and composition. The calculation approach can then be used to predict responses for animal body sizes and shapes relatively to those experimentally determined and to include the effect of tissue inhomogeneities. Our calculations were verified by experimental measurements performed for a set of cylindrical inhomogeneous phantoms. The calculated to experimental ratios observed were within 6%. (author)

  12. Assessment of bacterial contamination in the sectors of Clinical Medicine and Surgery Small Animal Veterinary Hospital, UFCG, PB

    Directory of Open Access Journals (Sweden)

    Rafaela Alves Dias

    2015-06-01

    Full Text Available ABSTRACT. Dias R.A., Souza A.P. & Garino Júnior F. [Assessment of bacterial contamination in the sectors of Clinical Medicine and Surgery Small Animal Veterinary Hospital, UFCG, PB.] Avaliação da contaminação bacteriana nos setores de Clínica e Cirurgia de Pequenos Animais do Hospital Veterinário da UFCG, PB. Revista Brasileira de Medicina Veterinária, 37(2:173-177, 2015. Programa de Pós-Graduação em Medicina Veterinária, Universidade Federal de Campina Grande, Av. Universitária, s/n, Bairro Santa Cecília, Patos, PB 58708-110, Brasil. E-mail: rafa.ad@hotmail.com With this study aimed to evaluate bacterial contamination sectors Clinic and Surgery Small Animal Veterinary Hospital UFCG, in order to prevent infections in patients attending hospital. An assessment of the environmental contamination of sectors before and after disinfection, where was collected samples of air, surfaces and hands of people who deal directly with the animals. Then the test was made of the effectiveness of disinfectants used. Of the 40 samples collected, was identified in 5 of them (12.5% Enterobacteria such as Escherichia coli and Klebisiella pneumoniae and in 22 samples (55% was identified Staphylococcus coagulase negative and positive. Was seen in the quantitative analysis that the number of cfu in some sample was above the indicated. The test showed that the disinfectant solution was effective against all micro-organisms found in the environments. The results indicate that more attention to procedures performed in the disinfection of areas evaluated, and also include measures to prevent contamination at these sites.

  13. ANIMAL ENTEROTOXIGENIC ESCHERICHIA COLI

    Science.gov (United States)

    Dubreuil, J. Daniel; Isaacson, Richard E.; Schifferli, Dieter M.

    2016-01-01

    Enterotoxigenic Escherichia coli (ETEC) is the most common cause of E. coli diarrhea in farm animals. ETEC are characterized by the ability to produce two types of virulence factors; adhesins that promote binding to specific enterocyte receptors for intestinal colonization and enterotoxins responsible for fluid secretion. The best-characterized adhesins are expressed in the context of fimbriae, such as the F4 (also designated K88), F5 (K99), F6 (987P), F17 and F18 fimbriae. Once established in the animal small intestine, ETEC produces enterotoxin(s) that lead to diarrhea. The enterotoxins belong to two major classes; heat-labile toxin that consist of one active and five binding subunits (LT), and heat-stable toxins that are small polypeptides (STa, STb, and EAST1). This chapter describes the disease and pathogenesis of animal ETEC, the corresponding virulence genes and protein products of these bacteria, their regulation and targets in animal hosts, as well as mechanisms of action. Furthermore, vaccines, inhibitors, probiotics and the identification of potential new targets identified by genomics are presented in the context of animal ETEC. PMID:27735786

  14. "Clean, green and ethical" animal production. Case study: reproductive efficiency in small ruminants.

    Science.gov (United States)

    Martin, Graeme B; Kadokawa, Hiroya

    2006-02-01

    In response to changes in society and thus the marketplace, we need a vision for the future of our animal industries, including both on-farm and off-farm activities, that is "clean, green and ethical". Using small ruminants as a case study, we describe three "clean, green and ethical" strategies that farmers could use to improve reproductive performance. The first allows control of the timing of reproductive events by using socio-sexual signals (the "male effect") to induce synchronised ovulation in females. The second strategy, "focus feeding", is based on using short periods of nutritional supplements that are precisely timed and specifically designed for each event in the reproductive process (eg, gamete production, embryo survival, fetal programming, colostrum production). The third strategy aims to maximize offspring survival by a combination of management, nutrition and genetic selection for behaviour (temperament). All of these approaches involve non-pharmacological manipulation of the endogenous control systems of the animals and complement the detailed information from ultrasound that is now becoming available. Importantly, these approaches all have a solid foundation in reproductive biology. In several cases, they are currently used in commercial practice, but there is still room for improvement through both basic and applied research. Ultimately, these "clean, green and ethical" tools can be cost-effective, increase productivity and, at the same time, greatly improve the image of meat and milk industries in society and the marketplace.

  15. Direct measurement of local oxygen concentration in the bone marrow of live animals

    Science.gov (United States)

    Spencer, Joel A.; Ferraro, Francesca; Roussakis, Emmanuel; Klein, Alyssa; Wu, Juwell; Runnels, Judith M.; Zaher, Walid; Mortensen, Luke J.; Alt, Clemens; Turcotte, Raphaël; Yusuf, Rushdia; Côté, Daniel; Vinogradov, Sergei A.; Scadden, David T.; Lin, Charles P.

    2014-04-01

    Characterization of how the microenvironment, or niche, regulates stem cell activity is central to understanding stem cell biology and to developing strategies for the therapeutic manipulation of stem cells. Low oxygen tension (hypoxia) is commonly thought to be a shared niche characteristic in maintaining quiescence in multiple stem cell types. However, support for the existence of a hypoxic niche has largely come from indirect evidence such as proteomic analysis, expression of hypoxia inducible factor-1α (Hif-1α) and related genes, and staining with surrogate hypoxic markers (for example, pimonidazole). Here we perform direct in vivo measurements of local oxygen tension (pO2) in the bone marrow of live mice. Using two-photon phosphorescence lifetime microscopy, we determined the absolute pO2 of the bone marrow to be quite low (hypoxic as it is perfused with small arteries that are often positive for the marker nestin. These pO2 values change markedly after radiation and chemotherapy, pointing to the role of stress in altering the stem cell metabolic microenvironment.

  16. Wireless Synchronization of a Multi-Pinhole Small Animal SPECT Collimation Device With a Clinical Scanner

    Science.gov (United States)

    DiFilippo, Frank P.; Patel, Sagar

    2009-06-01

    A multi-pinhole collimation device for small animal single photon emission computed tomography (SPECT) uses the gamma camera detectors of a standard clinical SPECT scanner. The collimator and animal bed move independently of the detectors, and therefore their motions must be synchronized. One approach is manual triggering of the SPECT acquisition simultaneously with a programmed motion sequence for the device. However, some data blurring and loss of image quality result, and true electronic synchronization is preferred. An off-the-shelf digital gyroscope with integrated Bluetooth interface provides a wireless solution to device synchronization. The sensor attaches to the SPECT gantry and reports its rotational speed to a notebook computer controlling the device. Software processes the rotation data in real-time, averaging the signal and issuing triggers while compensating for baseline drift. Motion commands are sent to the collimation device with minimal delay, within approximately 0.5 second of the start of SPECT gantry rotation. Test scans of a point source demonstrate an increase in true counts and a reduction in background counts compared to manual synchronization. The wireless rotation sensor provides robust synchronization of the collimation device with the clinical SPECT scanner and enhances image quality.

  17. Positive animal welfare states and reference standards for welfare assessment.

    Science.gov (United States)

    Mellor, D J

    2015-01-01

    Developments in affective neuroscience and behavioural science during the last 10-15 years have together made it increasingly apparent that sentient animals are potentially much more sensitive to their environmental and social circumstances than was previously thought to be the case. It therefore seems likely that both the range and magnitude of welfare trade-offs that occur when animals are managed for human purposes have been underestimated even when minimalistic but arguably well-intentioned attempts have been made to maintain high levels of welfare. In light of these neuroscience-supported behaviour-based insights, the present review considers the extent to which the use of currently available reference standards might draw attention to these previously neglected areas of concern. It is concluded that the natural living orientation cannot provide an all-embracing or definitive welfare benchmark because of its primary focus on behavioural freedom. However assessments of this type, supported by neuroscience insights into behavioural motivation, may now carry greater weight when used to identify management practices that should be avoided, discontinued or substantially modified. Using currently accepted baseline standards as welfare reference points may result in small changes being accorded greater significance than would be the case if they were compared with higher standards, and this could slow the progress towards better levels of welfare. On the other hand, using "what animals want" as a reference standard has the appeal of focusing on the specific resources or conditions the animals would choose themselves and can potentially improve their welfare more quickly than the approach of making small increments above baseline standards. It is concluded that the cautious use of these approaches in different combinations could lead to recommendations that would more effectively promote positive welfare states in hitherto neglected areas of concern.

  18. Companion animals and well-being in palliative care nursing: a literature review.

    Science.gov (United States)

    MacDonald, Julie M; Barrett, David

    2016-02-01

    To evaluate and critique current knowledge regarding the role of animals in palliative care. To explore the impact that animals may have on the well-being of individuals and to identify gaps in the evidence base. There is recognition that having a companion animal will affect patient experience. Similarly, there has been some previous exploration on the use of specific animal assisted therapies for patients with different healthcare needs. A literature review was conducted to identify published and unpublished research about companion animals or animal-assisted therapy in palliative and/or end-of-life care. The primary objective was to explore the impact of animals on well-being at the end of life. A search for literature was carried out using a variety of databases and different combinations of search terms linked to animals in palliative care. Included works were critically appraised and thematically analysed. A limited range of literature was identified. From the small number of studies included in the review (n = 4), it appears that there is some evidence of animals (either companion animals or those used specifically to enhance care) having a positive impact on the patient experience. This study suggests that animals play a large part in the lives of people receiving palliative care. Using animals to support care may also offer some benefits to the patient experience. However, there appears to be a dearth of high-quality literature in this area. More research is therefore required. Nurses providing palliative care need to be aware of the part that a companion animal may play in the life of patients. There may also be the opportunity for nurses in some settings to integrate animal therapy into their provision of palliative care. © 2015 John Wiley & Sons Ltd.

  19. Test–retest repeatability of quantitative cardiac 11C-meta-hydroxyephedrine measurements in rats by small animal positron emission tomography

    International Nuclear Information System (INIS)

    Thackeray, James T.; Renaud, Jennifer M.; Kordos, Myra; Klein, Ran; Kemp, Robert A. de; Beanlands, Rob S.B.; DaSilva, Jean N.

    2013-01-01

    Introduction: The norepinephrine analogue 11 C-meta-hydroxyephedrine (HED) has been used to interrogate sympathetic neuronal reuptake in cardiovascular disease. Application for longitudinal studies in small animal models of disease necessitates an understanding of test–retest variability. This study evaluated the repeatability of multiple quantitative cardiac measurements of HED retention and washout and the pharmacological response to reuptake blockade and enhanced norepinephrine levels. Methods: Small animal PET images were acquired over 60 min following HED administration to healthy male Sprague Dawley rats. Paired test and retest scans were undertaken in individual animals over 7 days. Additional HED scans were conducted following administration of norepinephrine reuptake inhibitor desipramine or continuous infusion of exogenous norepinephrine. HED retention was quantified by retention index, standardized uptake value (SUV), monoexponential and one-compartment washout. Plasma and cardiac norepinephrine were measured by high performance liquid chromatography. Results: Test retest variability was lower for retention index (15% ± 12%) and SUV (19% ± 15%) as compared to monoexponential washout rates (21% ± 13%). Desipramine pretreatment reduced myocardial HED retention index by 69% and SUV by 85%. Chase treatment with desipramine increased monoexponential HED washout by 197% compared to untreated controls. Norepinephrine infusion dose-dependently reduced HED accumulation, reflected by both retention index and SUV, with a corresponding increase in monoexponential washout. Plasma and cardiac norepinephrine levels correlated with HED quantitative measurements. Conclusion: The repeatability of HED retention index, SUV, and monoexponential washout supports its suitability for longitudinal PET studies in rats. Uptake and washout of HED are sensitive to acute increases in norepinephrine concentration

  20. SU-E-T-296: Dosimetric Analysis of Small Animal Image-Guided Irradiator Using High Resolution Optical CT Imaging of 3D Dosimeters

    International Nuclear Information System (INIS)

    Na, Y; Qian, X; Wuu, C; Adamovics, J

    2015-01-01

    Purpose: To verify the dosimetric characteristics of a small animal image-guided irradiator using a high-resolution of optical CT imaging of 3D dosimeters. Methods: PRESAEGE 3D dosimeters were used to determine dosimetric characteristics of a small animal image-guided irradiator and compared with EBT2 films. Cylindrical PRESAGE dosimeters with 7cm height and 6cm diameter were placed along the central axis of the beam. The films were positioned between 6×6cm 2 cubed plastic water phantoms perpendicular to the beam direction with multiple depths. PRESAGE dosimeters and EBT2 films were then irradiated with the irradiator beams at 220kVp and 13mA. Each of irradiated PRESAGE dosimeters named PA1, PA2, PB1, and PB2, was independently scanned using a high-resolution single laser beam optical CT scanner. The transverse images were reconstructed with a 0.1mm high-resolution pixel. A commercial Epson Expression 10000XL flatbed scanner was used for readout of irradiated EBT2 films at a 0.4mm pixel resolution. PDD curves and beam profiles were measured for the irradiated PRESAGE dosimeters and EBT2 films. Results: The PDD agreements between the irradiated PRESAGE dosimeter PA1, PA2, PB1, PB2 and the EB2 films were 1.7, 2.3, 1.9, and 1.9% for the multiple depths at 1, 5, 10, 15, 20, 30, 40 and 50mm, respectively. The FWHM measurements for each PRESAEGE dosimeter and film agreed with 0.5, 1.1, 0.4, and 1.7%, respectively, at 30mm depth. Both PDD and FWHM measurements for the PRESAGE dosimeters and the films agreed overall within 2%. The 20%–80% penumbral widths of each PRESAGE dosimeter and the film at a given depth were respectively found to be 0.97, 0.91, 0.79, 0.88, and 0.37mm. Conclusion: Dosimetric characteristics of a small animal image-guided irradiator have been demonstrated with the measurements of PRESAGE dosimeter and EB2 film. With the high resolution and accuracy obtained from this 3D dosimetry system, precise targeting small animal irradiation can be achieved

  1. Low-dose cardio-respiratory phase-correlated cone-beam micro-CT of small animals.

    Science.gov (United States)

    Sawall, Stefan; Bergner, Frank; Lapp, Robert; Mronz, Markus; Karolczak, Marek; Hess, Andreas; Kachelriess, Marc

    2011-03-01

    Micro-CT imaging of animal hearts typically requires a double gating procedure because scans during a breath-hold are not possible due to the long scan times and the high respiratory rates, Simultaneous respiratory and cardiac gating can either be done prospectively or retrospectively. True five-dimensional information can be either retrieved with retrospective gating or with prospective gating if several prospective gates are acquired. In any case, the amount of information available to reconstruct one volume for a given respiratory and cardiac phase is orders of magnitud lower than the total amount of information acquired. For example, the reconstruction of a volume from a 10% wide respiratory and a 20% wide cardiac window uses only 2% of the data acquired. Achieving a similar image quality as a nongated scan would therefore require to increase the amount of data and thereby the dose to the animal by up to a factor of 50. To achieve the goal of low-dose phase-correlated (LDPC) imaging, the authors propose to use a highly efficient combination of slightly modified existing algorithms. In particular, the authors developed a variant of the McKinnon-Bates image reconstruction algorithm and combined it with bilateral filtering in up to five dimensions to significantly reduce image noise without impairing spatial or temporal resolution. The preliminary results indicate that the proposed LDPC reconstruction method typically reduces image noise by a factor of up to 6 (e.g., from 170 to 30 HU), while the dose values lie in a range from 60 to 500 mGy. Compared to other publications that apply 250-1800 mGy for the same task [C. T. Badea et al., "4D micro-CT of the mouse heart," Mol. Imaging 4(2), 110-116 (2005); M. Drangova et al., "Fast retrospectively gated quantitative four-dimensional (4D) cardiac micro computed tomography imaging of free-breathing mice," Invest. Radiol. 42(2), 85-94 (2007); S. H. Bartling et al., "Retrospective motion gating in small animal CT of mice

  2. 9 CFR 113.27 - Detection of extraneous viable bacteria and fungi in live vaccines.

    Science.gov (United States)

    2010-01-01

    ... bacteria and fungi in live vaccines. 113.27 Section 113.27 Animals and Animal Products ANIMAL AND PLANT... bacteria and fungi in live vaccines. Unless otherwise specified by the Administrator or elsewhere exempted... Seed Bacteria shall be tested for extraneous viable bacteria and fungi as prescribed in this section. A...

  3. Speckle-modulating optical coherence tomography in living mice and humans

    Science.gov (United States)

    Liba, Orly; Lew, Matthew D.; Sorelle, Elliott D.; Dutta, Rebecca; Sen, Debasish; Moshfeghi, Darius M.; Chu, Steven; de La Zerda, Adam

    2017-06-01

    Optical coherence tomography (OCT) is a powerful biomedical imaging technology that relies on the coherent detection of backscattered light to image tissue morphology in vivo. As a consequence, OCT is susceptible to coherent noise (speckle noise), which imposes significant limitations on its diagnostic capabilities. Here we show speckle-modulating OCT (SM-OCT), a method based purely on light manipulation that virtually eliminates speckle noise originating from a sample. SM-OCT accomplishes this by creating and averaging an unlimited number of scans with uncorrelated speckle patterns without compromising spatial resolution. Using SM-OCT, we reveal small structures in the tissues of living animals, such as the inner stromal structure of a live mouse cornea, the fine structures inside the mouse pinna, and sweat ducts and Meissner's corpuscle in the human fingertip skin--features that are otherwise obscured by speckle noise when using conventional OCT or OCT with current state of the art speckle reduction methods.

  4. Interaction of the role of Concentrated Animal Feeding Operations (CAFOs) in Emerging Infectious Diseases (EIDS).

    Science.gov (United States)

    Hollenbeck, James E

    2016-03-01

    Most significant change in the evolution of the influenza virus is the rapid growth of the Concentrated Animal Feeding Operations (CAFOs) on a global scale. These industrial agricultural operations have the potential of housing thousands of animals in a relatively small area. Emerging Infectious Diseases (EIDs) event can be considered as a shift in the pathogen-host-environment interplay characteristics described by Engering et al. (2013). These changes in the host-environment and the disease ecology are key to creating novel transmission patterns and selection of novel pathogens with a modification of genetic traits. With the development of CAFOs throughout the world, the need for training of animal caretakers to observe, identify, treat, vaccinate and cull if necessary is important to safeguard public health. The best defense against another pandemic of Emerging Infectious Diseases (EIDs) is the constant monitoring of the livestock and handlers of CAFOs and the live animal markets. These are the most likely epicenter of the next pandemic. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. SU-E-T-89: Comprehensive Quality Assurance Phantom for the Small Animal Radiation Research Platform

    International Nuclear Information System (INIS)

    Jermoumi, M; Ngwa, W; Korideck, H; Zygmanski, P; Berbeco, R; Makrigiorgos, G; Cormack, R

    2014-01-01

    Purpose: Use of Small Animal Radiation Research Platform (SARRP) systems for conducting state-of-the-art image guided radiotherapy (IGRT) research on small animals has become more common over the past years. The purpose of this work is to develop and test the suitability and performance of a comprehensive quality assurance (QA) phantom for the SARRP. Methods: A QA phantom was developed for carrying out daily, monthly and annual QA tasks including imaging, dosimetry and treatment planning system (TPS) performance evaluation of the SARRP. The QA phantom consists of nine (60×60×5 mm3) KV-energy tissue equivalent solid water slabs that can be employed for annual dosimetry QA with film. Three of the top slabs are replaceable with ones incorporating Mosfets or OSLDs arranged in a quincunx pattern, or a slab drilled to accommodate an ion chamber insert. These top slabs are designed to facilitate routine daily and monthly QA tasks such as output constancy, isocenter congruency test, treatment planning system (TPS) QA, etc. One slab is designed with inserts for image QA. A prototype of the phantom was applied to test the performance of the imaging, planning and treatment delivery systems. Results: Output constancy test results showed daily variations within 3%. For isocenter congruency test, the phantom could be used to detect 0.3 mm deviations of the CBCT isocenter from the radiation isocenter. Using the Mosfet in phantom as target, the difference between TPS calculations and measurements was within 5%. Image-quality parameters could also be assessed in terms of geometric accuracy, CT number accuracy, linearity, noise and image uniformity, etc. Conclusion: The developed phantom can be employed as a simple tool for comprehensive performance evaluation of the SARRP. The study provides a reference for development of a comprehensive quality assurance program for the SARRP, with proposed tolerances and frequency of required tests

  6. SU-E-T-89: Comprehensive Quality Assurance Phantom for the Small Animal Radiation Research Platform

    Energy Technology Data Exchange (ETDEWEB)

    Jermoumi, M; Ngwa, W [University of Massachusetts Lowell, MA (United States); Dana-Farber Cancer Institute, Brigham and Women' s Hospital, Harvard Medical School, Boston, MA (United States); Korideck, H; Zygmanski, P; Berbeco, R; Makrigiorgos, G; Cormack, R [Dana-Farber Cancer Institute, Brigham and Women' s Hospital, Harvard Medical School, Boston, MA (United States)

    2014-06-01

    Purpose: Use of Small Animal Radiation Research Platform (SARRP) systems for conducting state-of-the-art image guided radiotherapy (IGRT) research on small animals has become more common over the past years. The purpose of this work is to develop and test the suitability and performance of a comprehensive quality assurance (QA) phantom for the SARRP. Methods: A QA phantom was developed for carrying out daily, monthly and annual QA tasks including imaging, dosimetry and treatment planning system (TPS) performance evaluation of the SARRP. The QA phantom consists of nine (60×60×5 mm3) KV-energy tissue equivalent solid water slabs that can be employed for annual dosimetry QA with film. Three of the top slabs are replaceable with ones incorporating Mosfets or OSLDs arranged in a quincunx pattern, or a slab drilled to accommodate an ion chamber insert. These top slabs are designed to facilitate routine daily and monthly QA tasks such as output constancy, isocenter congruency test, treatment planning system (TPS) QA, etc. One slab is designed with inserts for image QA. A prototype of the phantom was applied to test the performance of the imaging, planning and treatment delivery systems. Results: Output constancy test results showed daily variations within 3%. For isocenter congruency test, the phantom could be used to detect 0.3 mm deviations of the CBCT isocenter from the radiation isocenter. Using the Mosfet in phantom as target, the difference between TPS calculations and measurements was within 5%. Image-quality parameters could also be assessed in terms of geometric accuracy, CT number accuracy, linearity, noise and image uniformity, etc. Conclusion: The developed phantom can be employed as a simple tool for comprehensive performance evaluation of the SARRP. The study provides a reference for development of a comprehensive quality assurance program for the SARRP, with proposed tolerances and frequency of required tests.

  7. Key roles of Arf small G proteins and biosynthetic trafficking for animal development.

    Science.gov (United States)

    Rodrigues, Francisco F; Harris, Tony J C

    2017-04-14

    Although biosynthetic trafficking can function constitutively, it also functions specifically for certain developmental processes. These processes require either a large increase to biosynthesis or the biosynthesis and targeted trafficking of specific players. We review the conserved molecular mechanisms that direct biosynthetic trafficking, and discuss how their genetic disruption affects animal development. Specifically, we consider Arf small G proteins, such as Arf1 and Sar1, and their coat effectors, COPI and COPII, and how these proteins promote biosynthetic trafficking for cleavage of the Drosophila embryo, the growth of neuronal dendrites and synapses, extracellular matrix secretion for bone development, lumen development in epithelial tubes, notochord and neural tube development, and ciliogenesis. Specific need for the biosynthetic trafficking system is also evident from conserved CrebA/Creb3-like transcription factors increasing the expression of secretory machinery during several of these developmental processes. Moreover, dysfunctional trafficking leads to a range of developmental syndromes.

  8. Setting the One Health Agenda and the Human–Companion Animal Bond

    Directory of Open Access Journals (Sweden)

    Gregg K. Takashima

    2014-10-01

    Full Text Available “One Health”, also called “One Medicine”, began as an initiative advocating greater integration of human and animal medicine, in the 1800s. This concept has recently come to prominence, driven by the recognition that 75% of the newly emerging infectious diseases will arise from animal reservoirs, and that successful control and prevention will require a coordinated human medical and veterinary approach. Consequently, many One Health discussions have centered on the surveillance of animals in order to anticipate the potential emergence of new zoonotic diseases. An area that has been given only cursory mention, are the many ways that small companion animals benefit individual, community and possibly world health. The goal of this paper is to briefly review some of the evidenced-based data concerning the benefits of having companion animals in our lives, focusing on four major areas; cancer, heart disease, autism spectrum disorder (ASD, and the potential positive economic effects of the human-companion animal bond on One Health. Heart disease and cancer are the two leading causes of morbidity and mortality in the world, while ASD is a growing concern, not only for its individual effects, but also for its effect on family units, educational institutions, and its social implications for the community. In addition, these diseases can greatly affect the national and global cost of healthcare, as well as the economic output of a nation. It is therefore important to include and build on the concept of the Human-Animal Bond (HAB as it relates to healthcare in these areas.

  9. SPECT data acquisition and image reconstruction in a stationary small animal SPECT/MRI system

    Science.gov (United States)

    Xu, Jingyan; Chen, Si; Yu, Jianhua; Meier, Dirk; Wagenaar, Douglas J.; Patt, Bradley E.; Tsui, Benjamin M. W.

    2010-04-01

    The goal of the study was to investigate data acquisition strategies and image reconstruction methods for a stationary SPECT insert that can operate inside an MRI scanner with a 12 cm bore diameter for simultaneous SPECT/MRI imaging of small animals. The SPECT insert consists of 3 octagonal rings of 8 MR-compatible CZT detectors per ring surrounding a multi-pinhole (MPH) collimator sleeve. Each pinhole is constructed to project the field-of-view (FOV) to one CZT detector. All 24 pinholes are focused to a cylindrical FOV of 25 mm in diameter and 34 mm in length. The data acquisition strategies we evaluated were optional collimator rotations to improve tomographic sampling; and the image reconstruction methods were iterative ML-EM with and without compensation for the geometric response function (GRF) of the MPH collimator. For this purpose, we developed an analytic simulator that calculates the system matrix with the GRF models of the MPH collimator. The simulator was used to generate projection data of a digital rod phantom with pinhole aperture sizes of 1 mm and 2 mm and with different collimator rotation patterns. Iterative ML-EM reconstruction with and without GRF compensation were used to reconstruct the projection data from the central ring of 8 detectors only, and from all 24 detectors. Our results indicated that without GRF compensation and at the default design of 24 projection views, the reconstructed images had significant artifacts. Accurate GRF compensation substantially improved the reconstructed image resolution and reduced image artifacts. With accurate GRF compensation, useful reconstructed images can be obtained using 24 projection views only. This last finding potentially enables dynamic SPECT (and/or MRI) studies in small animals, one of many possible application areas of the SPECT/MRI system. Further research efforts are warranted including experimentally measuring the system matrix for improved geometrical accuracy, incorporating the co

  10. 9 CFR 201.82 - Care and promptness in weighing and handling livestock and live poultry.

    Science.gov (United States)

    2010-01-01

    ... handling livestock and live poultry. 201.82 Section 201.82 Animals and Animal Products GRAIN INSPECTION... handling livestock and live poultry. (a) Each stockyard owner, market agency, dealer, packer and live poultry dealer shall exercise reasonable care and promptness with respect to loading, transporting...

  11. A computational pipeline for quantification of pulmonary infections in small animal models using serial PET-CT imaging.

    Science.gov (United States)

    Bagci, Ulas; Foster, Brent; Miller-Jaster, Kirsten; Luna, Brian; Dey, Bappaditya; Bishai, William R; Jonsson, Colleen B; Jain, Sanjay; Mollura, Daniel J

    2013-07-23

    Infectious diseases are the second leading cause of death worldwide. In order to better understand and treat them, an accurate evaluation using multi-modal imaging techniques for anatomical and functional characterizations is needed. For non-invasive imaging techniques such as computed tomography (CT), magnetic resonance imaging (MRI), and positron emission tomography (PET), there have been many engineering improvements that have significantly enhanced the resolution and contrast of the images, but there are still insufficient computational algorithms available for researchers to use when accurately quantifying imaging data from anatomical structures and functional biological processes. Since the development of such tools may potentially translate basic research into the clinic, this study focuses on the development of a quantitative and qualitative image analysis platform that provides a computational radiology perspective for pulmonary infections in small animal models. Specifically, we designed (a) a fast and robust automated and semi-automated image analysis platform and a quantification tool that can facilitate accurate diagnostic measurements of pulmonary lesions as well as volumetric measurements of anatomical structures, and incorporated (b) an image registration pipeline to our proposed framework for volumetric comparison of serial scans. This is an important investigational tool for small animal infectious disease models that can help advance researchers' understanding of infectious diseases. We tested the utility of our proposed methodology by using sequentially acquired CT and PET images of rabbit, ferret, and mouse models with respiratory infections of Mycobacterium tuberculosis (TB), H1N1 flu virus, and an aerosolized respiratory pathogen (necrotic TB) for a total of 92, 44, and 24 scans for the respective studies with half of the scans from CT and the other half from PET. Institutional Administrative Panel on Laboratory Animal Care approvals were

  12. Use of Laboratory Animals in Biomedical and Behavioral Research.

    Science.gov (United States)

    Ministry of Education, Addis Ababa (Ethiopia).

    The use of animals in scientific research has been a controversial issue for over a hundred years. Research with animals has saved human lives, lessened human suffering, and advanced scientific understanding, yet that same research can cause pain and distress for the animals involved and may result in their death. It is hardly surprising that…

  13. Radiography atlas of domestic animals. Small mammals, birds, reptilia, and amphibia. Atlas der Roentgendiagnostik bei Heimtieren. Kleinsaeuger, Voegel, Reptilien und Amphibien

    Energy Technology Data Exchange (ETDEWEB)

    Ruebel, G.A.; Isenbuegel, E.; Wolvekamp, P. (eds.); Gabrisch, K.; Grimm, F.; Koblik, P.; Paul-Murphy, J.; Oschwald, C.P.; Schildger, B.J.

    1991-01-01

    The 370 radiographs presented in the atlas together with notes and explanations give information on normal roentgenographic findings, physiological variations, and important pathological findings observed in small mammals, birds, reptilia and amphibia. Introductory notes to each chapter explain the principles of exposure techniques and the handling of the animals. (VHE).

  14. Influence of orthopedic reinforced gloves versus double standard gloves on contamination events during small animal orthopedic surgery.

    Science.gov (United States)

    Hayes, Galina; Singh, Ameet; Gibson, Tom; Moens, Noel; Oblak, Michelle; Ogilvie, Adam; Reynolds, Debbie

    2017-10-01

    To determine the influence of orthopedic reinforced gloves on contamination events during small animal orthopedic surgery. Prospective randomized controlled trial SAMPLE POPULATION: Two hundred and thirty-seven pairs of orthopedic gloves (474 gloves) and 203 pairs of double standard gloves (812 gloves) worn during 193 orthopedic procedures. Primary and assistant surgeons were randomized to wear either orthopedic reinforced gloves or double gloves. Gloves were leak tested to identify perforations at the end of procedures. Perforations detected intraoperatively or postoperatively were recorded. A contamination event was defined as at least one perforation on either hand for orthopedic reinforced gloves, or a perforation of both the inner and outer glove on the same hand for double gloves. Baseline characteristics between the 2 intervention groups were similar. There was no difference in contamination events between the double-gloved and orthopedic gloved groups (OR = 0.95, 95% CI = 0.49-1.87, P = .89). The same percentage of contamination events (8% glove pairs used) occurred in the double gloved group (17 contamination events) and in the orthopedic gloved group (19 contamination events). The odds of a contamination event increased by 1.02 (95% CI 1.01-1.03, P contamination events in small animal orthopedic procedures. Surgeons reluctant to double glove due to perceptions of decreased dexterity and discomfort may safely opt for wearing orthopedic gloves, which may improve their compliance. © 2017 The American College of Veterinary Surgeons.

  15. PET performance evaluation of MADPET4: a small animal PET insert for a 7 T MRI scanner

    Science.gov (United States)

    Omidvari, Negar; Cabello, Jorge; Topping, Geoffrey; Schneider, Florian R.; Paul, Stephan; Schwaiger, Markus; Ziegler, Sibylle I.

    2017-11-01

    MADPET4 is the first small animal PET insert with two layers of individually read out crystals in combination with silicon photomultiplier technology. It has a novel detector arrangement, in which all crystals face the center of field of view transaxially. In this work, the PET performance of MADPET4 was evaluated and compared to other preclinical PET scanners using the NEMA NU 4 measurements, followed by imaging a mouse-size hot-rod resolution phantom and two in vivo simultaneous PET/MRI scans in a 7 T MRI scanner. The insert had a peak sensitivity of 0.49%, using an energy threshold of 350 keV. A uniform transaxial resolution was obtained up to 15 mm radial offset from the axial center, using filtered back-projection with single-slice rebinning. The measured average radial and tangential resolutions (FWHM) were 1.38 mm and 1.39 mm, respectively. The 1.2 mm rods were separable in the hot-rod phantom using an iterative image reconstruction algorithm. The scatter fraction was 7.3% and peak noise equivalent count rate was 15.5 kcps at 65.1 MBq of activity. The FDG uptake in a mouse heart and brain were visible in the two in vivo simultaneous PET/MRI scans without applying image corrections. In conclusion, the insert demonstrated a good overall performance and can be used for small animal multi-modal research applications.

  16. Farm animal proteomics - A review

    DEFF Research Database (Denmark)

    Bendixen, Emøke; Danielsen, Marianne; Hollung, Kristin

    2011-01-01

    In agricultural sciences as in all other areas of life science, the implementation of proteomics and other post-genomic tools is an important step towards more detailed understanding of the complex biological systems that control physiology and pathology of living beings. Farm animals are raised...... and cattle are relevant not only for farm animal sciences, but also for adding to our understanding of complex biological mechanisms of health and disease in humans. The aim of this review is to present an overview of the specific topics of interest within farm animal proteomics, and to highlight some...... of the areas where synergy between classic model organism proteomics and farm animal proteomics is rapidly emerging. Focus will be on introducing the special biological traits that play an important role in food production, and on how proteomics may help optimize farm animal production...

  17. A new design for high stability pressure-controlled ventilation for small animal lung imaging

    International Nuclear Information System (INIS)

    Kitchen, M J; Habib, A; Lewis, R A; Fouras, A; Dubsky, S; Wallace, M J; Hooper, S B

    2010-01-01

    We have developed a custom-designed ventilator to deliver a stable pressure to the lungs of small animals for use in imaging experiments. Our ventilator was designed with independent pressure vessels to separately control the Peak Inspiratory Pressure (PIP) and Positive End Expiratory Pressure (PEEP) to minimise pressure fluctuations during the ventilation process. The ventilator was computer controlled through a LabVIEW interface, enabling experimental manipulations to be performed remotely whilst simultaneously imaging the lungs in situ. Mechanical ventilation was successfully performed on newborn rabbit pups to assess the most effective ventilation strategies for aerating the lungs at birth. Highly stable pressures enabled reliable respiratory gated acquisition of projection radiographs and a stable prolonged (15 minute) breath-hold for high-resolution computed tomography of deceased rabbit pups at different lung volumes.

  18. Physical and biological dosimetry at the RA-3 facility for small animal irradiation: preliminary BNCT studies in an experimental model of oral cancer

    International Nuclear Information System (INIS)

    Pozzi, Emiliano; Miller, Marcelo; Thorp, Silvia I.; Heber, Elisa M.; Trivillin, Veronica A.; Zarza, Leandro; Estryk, Guillermo; Schwint, Amanda E.; Nigg, David W.

    2007-01-01

    Boron Neutron Capture Therapy (BNCT) is a binary treatment modality based on the capture reaction that occurs between thermal neutrons and boron-10 atoms that accumulate selectively in tumor tissue, emitting high linear energy transfer (LET), short range (5-9 microns) particles (alpha y 7 Li). Thus, BNCT would potentially target tumor tissue selectively, sparing normal tissue. Herein we evaluated the feasibility of treating experimental oral mucosa tumors with BNCT at RA-3 (CAE) employing the hamster cheek pouch oral cancer model and characterized the irradiation field at the RA-3 facility. We evaluated the therapeutic effect on tumor of BNCT mediated by BPA in the hamster cheek pouch oral cancer model and the potential radio toxic effects in normal tissue. We evidenced a moderate biological response in tumor, with no radio toxic effects in normal tissue following irradiations with no shielding for the animal body. Given the sub-optimal therapeutic response, we designed and built a 6 Li 2 CO 3 shielding for the body of the animal to increase the irradiation dose to tumor, without exceeding normal tissue radio tolerance. The measured absolute magnitude of thermal neutron flux and the characterization of the beam with and without the shielding in place, suggest that the irradiation facility in the thermal column of RA-3 would afford an excellent platform to perform BNCT studies in vitro and in vivo in small experimental animals. The present findings must be confirmed and extended by performing in vivo BNCT radiobiological studies in small experimental animals, employing the shielding device for the animal body. (author) [es

  19. Understanding Motion Capture for Computer Animation

    CERN Document Server

    Menache, Alberto

    2010-01-01

    The power of today's motion capture technology has taken animated characters and special effects to amazing new levels of reality. And with the release of blockbusters like Avatar and Tin-Tin, audiences continually expect more from each new release. To live up to these expectations, film and game makers, particularly technical animators and directors, need to be at the forefront of motion capture technology. In this extensively updated edition of Understanding Motion Capture for Computer Animation and Video Games, an industry insider explains the latest research developments in digital design

  20. SmartPET: Applying HPGe and pulse shape analysis to small-animal PET

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, R.J. [Department of Physics, University of Liverpool (United Kingdom)], E-mail: rjc@ns.ph.liv.ac.uk; Boston, A.J.; Boston, H.C.; Cresswell, J.R.; Grint, A.N.; Mather, A.R.; Nolan, P.J.; Scraggs, D.P.; Turk, G. [Department of Physics, University of Liverpool (United Kingdom); Hall, C.J.; Lazarus, I. [CCLRC Daresbury Laboratory, Warrington, Cheshire (United Kingdom); Berry, A.; Beveridge, T.; Gillam, J.; Lewis, R.A. [School of Physics and Materials Engineering, Monash University, Melbourne (Australia)

    2007-08-21

    The SmartPET project is the development of a prototype small-animal imaging system based on the use of Hyperpure Germanium (HPGe) detectors. The use of digital electronics and application of Pulse Shape Analysis (PSA) techniques provide fine spatial resolution, while the excellent intrinsic energy resolution of HPGe detectors makes the system ideal for multi-nuclide imaging. As a result, the SmartPET system has the potential to function as a dual modality imager, operating as a dual-head Positron Emission Tomography (PET) camera or in a Compton Camera configuration for Single Photon Emission Computed Tomography (SPECT) imaging. In this paper, we discuss how the use of simple PSA techniques greatly improves the position sensitivity of the detector yielding improved spatial resolution in reconstructed images. The PSA methods presented have been validated by comparison to data from high-precision scanning of the detectors. Results from this analysis are presented along with initial images from the SmartPET system, which demonstrates the impact of these techniques on PET images.