WorldWideScience

Sample records for liquid-based single-drop microextraction

  1. Ultra-Trace Determination of Copper and Silver in Environmental Samples by Using Ionic Liquid-Based Single Drop Microextraction-Electrothermal Atomic Absorption Spectrometry

    Directory of Open Access Journals (Sweden)

    J. Abolhasani

    2013-11-01

    Full Text Available A sensitive, selective and effective ionic liquid-based single drop microextraction technique wasdeveloped by using ionic liquid, 1-hexyl-3-methylimidazolium hexafluorophosphate, C6MIMPF6, coupledwith electrothermal atomic absorption spectrometry (ETAAS for the determination of copper and silver inenvironmental samples. Dithizone was used as chelating agent. Several factors that influence themicroextraction efficiency and ETAAS signal, such as pH, dithizone concentration, extraction time, amounts ofionic liquid, stirring rate, pyrolysis and atomization temperature were investigated and the microextractionconditions were established. In the optimum experimental conditions, the detection limits (3 s of the methodwere 4 and 8 ng L-1 and corresponding relative standard deviations (0.1 μg L-1, n = 6 were 4.2% and 4.8% forAg and Cu, respectively. The developed method was validated by analysis of a certified reference material andapplied to the determination of silver and copper.

  2. Fully automated ionic liquid-based headspace single drop microextraction coupled to GC-MS/MS to determine musk fragrances in environmental water samples.

    Science.gov (United States)

    Vallecillos, Laura; Pocurull, Eva; Borrull, Francesc

    2012-09-15

    A fully automated ionic liquid-based headspace single drop microextraction (IL-HS-SDME) procedure has been developed for the first time to preconcentrate trace amounts of ten musk fragrances extensively used in personal care products (six polycyclic musks, three nitro musks and one polycyclic musk degradation product) from wastewater samples prior to analysis by gas chromatography and ion trap tandem mass spectrometry (GC-IT-MS/MS). Due to the low volatility of the ILs, a large internal diameter liner (3.4 mm i.d.) was used to improve the ILs evaporation. Furthermore, a piece of glass wool was introduced into the liner to avoid the entrance of the ILs in the GC column and a guard column was used to prevent analytical column damages. The main factors influencing the IL-HS-SDME were optimized. For all species, the highest enrichments factors were achieved using 1 μL of 1-octyl-3-methylimidazolium hexafluorophosphate ([OMIM][PF(6)]) ionic liquid exposed in the headspace of 10 mL water samples containing 300 g L(-1) of NaCl and stirred at 750 rpm and 60 °C for 45 min. All compounds were determined by direct injection GC-IT-MS/MS with a chromatographic time of 19 min. Method detection limits were found in the low ng mL(-1) range between 0.010 ng mL(-1) and 0.030 ng mL(-1) depending on the target analytes. Also, under optimized conditions, the method gave good levels of intra-day and inter-day repeatabilities in wastewater samples with relative standard deviations varying between 3% and 6% and 5% and 11%, respectively (n=3, 1 ng mL(-1)). The applicability of the method was tested with different wastewater samples from influent and effluent urban wastewater treatment plants (WWTPs) and one potable treatment plant (PTP). The analysis of influent urban wastewater revealed the presence of galaxolide and tonalide at concentrations of between 2.10 ng mL(-1) and 0.29 ng mL(-1) and 0.32 ng mL(-1) and waters from PTP only galaxolide was found at a concentration higher than MQL.

  3. Determination of Trace Amounts of Lead with ETAAS After Single Drop Microextraction and Dispersive Liquid Liquid Microextraction Methods

    OpenAIRE

    Efeçınar M.; Çakır P.; Şatıroğlu N.

    2013-01-01

    Two liquid-phase microextraction procedures, single-drop microextraction (SDME) and dispersive liquid–liquid microextraction (DLLME), have been developed for the determination of lead by electrothermal atomic absorption spectrometry (ETAAS). Both methods were based on the formation of lead iodide-Rhodamine B complex which is in phosphoric acid medium. In the presence of KI, anionic lead iodide was complexed with Rhodamine B as an ion-association complex. Several factors that may be affected o...

  4. Headspace single drop microextraction coupled with microwave extraction of essential oil from plant materials.

    Science.gov (United States)

    Zhai, Yujuan; Sun, Shuo; Wang, Ziming; Zhang, Yupu; Liu, He; Sun, Ye; Zhang, Hanqi; Yu, Aimin

    2011-05-01

    Headspace single drop microextraction (HS-SDME) coupled with microwave extraction (ME) was developed and applied to the extraction of the essential oil from dried Syzygium aromaticum (L.) Merr. et Perry and Cuminum cyminum L. The operational parameters, such as microdrop volume, microwave absorption medium (MAM), extraction time, and microwave power were optimized. Ten microliters of decane was used as the microextraction solvent. Ionic liquid and carbonyl iron powder were used as MAM. The extraction time was less than 7 min at the microwave power of 440 W. The proposed method was compared with hydrodistillation (HD). There were no obvious differences in the constituents of essential oils obtained by the two methods.

  5. Single-drop liquid phase microextraction accelerated by surface acoustic wave.

    Science.gov (United States)

    Zhang, Anliang; Zha, Yan

    2013-03-01

    A single-drop liquid phase microextraction method is presented, in which surface acoustic wave (SAW) is used for accelerating extraction speed. A pair of interdigital transducers with 27.5 MHz center frequency is fabricated on a 128° yx-LiNbO3 substrate. A radio frequency signal is applied to one of interdigital transducers to excite SAW. Plastic straw is filled with PDMS, leaving 1 mL for holding sample solution. Plastic straw with sample solution droplet is then dipping into extractant, into which SAW is radiated. Mass transportation from sample solution to extractant drop is accelerated due to acoustic streaming, and extraction time is decreased. An ionic liquid and an acid green-25 solution are used for extraction experiments. Results show that the extraction process is almost finished within 2 min, and extraction speed is increased with radio frequency signal power.

  6. Determination of Trace Amounts of Lead with ETAAS After Single Drop Microextraction and Dispersive Liquid Liquid Microextraction Methods

    Directory of Open Access Journals (Sweden)

    Efeçınar M.

    2013-04-01

    Full Text Available Two liquid-phase microextraction procedures, single-drop microextraction (SDME and dispersive liquid–liquid microextraction (DLLME, have been developed for the determination of lead by electrothermal atomic absorption spectrometry (ETAAS. Both methods were based on the formation of lead iodide-Rhodamine B complex which is in phosphoric acid medium. In the presence of KI, anionic lead iodide was complexed with Rhodamine B as an ion-association complex. Several factors that may be affected on the SDME and DLLME methods were optimized. In the optimum experimental conditions, the limit of detection (3s and the enhancement factor were 0.008 μgL−1 and 152 for SDME and 0.0129 μgL−1 and 89 for DLLME respectively. The relative standard deviation (RSD for eight replicate determinations of 0.25 μgL−1 Pb was 4.6% for SDME and 0.5 μgL−1 Pb was 2.9% for DLLME. The developed methods were validated by the analysis of certified reference materials, and applied successfully to the determination of lead in several water and food samples.

  7. Fast analysis of volatile components of Achillea tenuifolia Lam with microwave distillation followed by headspace single-drop microextraction coupled to gas chromatography-mass spectrometry (GC-MS).

    Science.gov (United States)

    Piryaei, Marzieh; Nazemiyeh, Hossein

    2016-01-01

    This article investigates the effect of microwaves on the amount of volatile compounds Achillea tenuifolia Lam with two methods, headspace single-drop microextraction and microwave-assisted headspace single-drop microextraction (MA-SDME), for the analysis of essential oil. Solvent selection, solvent volume, microwave power, irradiation time and sample mass were optimised by the simplex method.

  8. Immersed single-drop microextraction-electrothermal vaporization atomic absorption spectroscopy for the trace determination of mercury in water samples.

    Science.gov (United States)

    Bagheri, Habib; Naderi, Mehrnoush

    2009-06-15

    A new method based on single-drop microextraction (SDME) combined with electrothermal vaporization atomic absorption spectroscopy (ETV-AAS) was developed for the trace determination of mercury in water samples. A microdrop of m-xylene was applied as the extraction solvent. After extraction, the microdrop was introduced, directly, into a graphite furnace of AAS. Some important extraction parameters such as type of solvent, volume of solvent, sample stirring, ionic strength, sample pH, chelating agent concentration, sample temperature, and extraction time were investigated and optimized. The highest possible microdrop volume of 10 microL, a sampling temperature of 27 degrees C, and use of m-xylene containing dithizone, as complexing agent, are major parameters led to achieve a high enrichment factor of 970. Under the optimized conditions, the detection limit of the method was 0.01 microg L(-1) and the relative standard deviation was 6.1% (n=7). The proposed method has been successfully applied to the determination of Hg in two river water samples. The effects of interfering species such as Pt, Pd, Cu, Au, and Bi, having the tendency to form complexes with dithizone, at two concentration levels of 100 and 1000 microg L(-1) were also studied.

  9. Microwave distillation followed by headspace single drop microextraction coupled to gas chromatography-mass spectrometry (GC-MS) for fast analysis of volatile components of Echinophora platyloba DC.

    Science.gov (United States)

    Gholivand, Mohammad Bagher; Abolghasemi, Mir Mahdi; Piryaei, Marzieh; Maassoumi, Sayed Mohammad; Papzan, Abdolhamid

    2013-05-01

    To avoid the traditional and time consuming hydrodistillation, the analyses of volatile components in aerial parts of Echinophora platyloba DC was carried out by a simple microwave distillation followed by headspace single drop microextraction (MD-HS-SDME) coupled to gas chromatography-mass spectrometry (GC-MS). The headspace volatile compounds were collected after irradiation using a single drop of n-heptadecan. The extraction conditions were optimised using the relative peak areas as index. The chemical composition of the MD-HS-SDME extracts was confirmed according to their retention indexes and mass spectra. Fifty-three components were extracted and identified by using the MD-HS-SDME method. E-β-ocimene (53.81%), R-D-decalactone (12.75%), α-pinene (6.43%), n-heptanol (6.27%), β-phellanderne (2.70%) and linalool (1.89%) were the major constituents. Copyright © 2012 Elsevier Ltd. All rights reserved.

  10. Determination of bisphenol A in thermal printing papers treated by alkaline aqueous solution using the combination of single-drop microextraction and HPLC.

    Science.gov (United States)

    Gao, Leihong; Zou, Jing; Liu, Haihong; Zeng, Jingbin; Wang, Yiru; Chen, Xi

    2013-04-01

    A method for the quantitative determination of bisphenol A in thermal printing paper was developed and validated. Bisphenol A was extracted from the paper samples using 2% NaOH solution, then the extracted analyte was enriched using single-drop microextraction followed by HPLC analysis. Several parameters relating to the single-drop microextraction efficiency including extraction solvent, extraction temperature and time, stirring rate, and pH of donor phase were studied and optimized. Spiked recovery of bisphenol A at 20 and 5 mg/g was found to be 95.8 and 108%, and the method detection limit and method quantification limit was 0.03 and 0.01 mg/g, respectively. Under the optimized conditions, the proposed method was applied to the determination of bisphenol A in seven types of thermal printing paper samples, and the concentration of bisphenol A was found in the range of 0.53-20.9 mg/g. The considerably minimum usage of organic solvents (5 μL 1-octanol) and high enrichment factor (189-197) in the sample preparation are the two highlighted advantages in comparison with previously published works.

  11. Ultrasonic nebulization extraction-heating gas flow transfer-headspace single drop microextraction of essential oil from pericarp of Zanthoxylum bungeanum Maxim.

    Science.gov (United States)

    Wei, Shigang; Zhang, Huihui; Wang, Yeqiang; Wang, Lu; Li, Xueyuan; Wang, Yinghua; Zhang, Hanqi; Xu, Xu; Shi, Yuhua

    2011-07-22

    The ultrasonic nebulization extraction-heating gas flow transfer coupled with headspace single drop microextraction (UNE-HGFT-HS-SDME) was developed for the extraction of essential oil from Zanthoxylum bungeanum Maxim. The gas chromatography-mass spectrometry was applied to the determination of the constituents in the essential oil. The contents of the constituents from essential oil obtained by the proposed method were found to be more similar to those obtained by hydro-distillation (HD) than those obtained by ultrasonic nebulization extraction coupled with headspace single drop microextraction (UNE-HS-SDME). The heating gas flow was firstly used in the analysis of the essential oil to transfer the analytes from the headspace to the solvent microdrop. The relative standard deviations for determining the five major constituents were in the range from 1.5 to 6.7%. The proposed method is a fast, sensitive, low cost and small sample consumption method for the determination of the volatile and semivolatile constituents in the plant materials.

  12. Enhancement of Sensitivity for Determination of Phenols in Environmental Water Samples by Single-drop Liquid Phase Microextraction Using Ionic Liquid prior to HPLC

    Institute of Scientific and Technical Information of China (English)

    Qing Xiang ZHOU; Jun Ping XIAO; Cun Ling YE; Xin Ming WANG

    2006-01-01

    A single-drop liquid phase micro-extraction procedure using 1-butyl-3-methylimidazolium hexafluorophosphate ([C4MIM][PF6]) was demonstrated for the sensitive determination of four phenols in water samples. Under the optimized conditions, the linear range of proposed phenol, 2-naphthol, 2-nitrophenol and 4-chlorophenol, respectively. The experimental results indicated that the effect of complex matrices natural water samples could be resolved with addition of sodium ethylene diamine tetracetate (EDTA) into the samples. Excellent spiked recoveries were achieved for these four phenols ranged from 86.2%-114.9 %. All these facts demonstrated that the proposed method with merits of low cost, simplicity and easy operating would be a competitive alternative procedure for the determination of such compounds at trace level.

  13. Automated in-syringe single-drop head-space micro-extraction applied to the determination of ethanol in wine samples.

    Science.gov (United States)

    Srámková, Ivana; Horstkotte, Burkhard; Solich, Petr; Sklenářová, Hana

    2014-05-30

    A novel approach of head-space single-drop micro-extraction applied to the determination of ethanol in wine is presented. For the first time, the syringe of an automated syringe pump was used as an extraction chamber of adaptable size for a volatile analyte. This approach enabled to apply negative pressure during the enrichment step, which favored the evaporation of the analyte. Placing a slowly spinning magnetic stirring bar inside the syringe, effective syringe cleaning as well as mixing of the sample with buffer solution to suppress the interference of acetic acid was achieved. Ethanol determination was based on the reduction of a single drop of 3mmol L(-1) potassium dichromate dissolved in 8mol L(-1) sulfuric acid. The drop was positioned in the syringe inlet in the head-space above the sample with posterior spectrophotometric quantification. The entire procedure was carried out automatically using a simple sequential injection analyzer system. One analysis required less than 5min including the washing step. A limit of detection of 0.025% (v/v) of ethanol and an average repeatability of less than 5.0% RSD were achieved. The consumption of dichromate reagent, buffer, and sample per analysis were only 20μL, 200μL, and 1mL, respectively. The results of real samples analysis did not differ significantly from those obtained with the references gas chromatography method. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Speciation and determination of inorganic mercury and methylmercury by headspace single drop microextraction and electrothermal atomic absorption spectrometry in water and fish

    Energy Technology Data Exchange (ETDEWEB)

    Sarica, Deniz Yurtsever [Scientific and Technological Research Council of Turkey, Ankara Test and Analysis Laboratory, TUeBITAK/ATAL, Besevler, Ankara (Turkey); Tuerker, Ali Rehber [Science Faculty, Department of Chemistry, Gazi University, Ankara (Turkey)

    2012-05-15

    In this study, headspace single drop microextraction (HS-SDME) method in combination with electrothermal atomic absorption spectrometry (ETAAS) method was developed and validated for the speciation and determination of inorganic mercury (iHg) and methylmercury (MeHg). MeHg and iHg species were reduced to volatile methylmercury hydride (CH{sub 3}HgH) and elemental mercury, respectively, in the presence of NaBH{sub 4} and trapped onto a drop of acceptor phase in the tip of a microsyringe. Thiourea and ammonium pyrrolydinedithiocarbamate (APDC) were tested as the acceptor phase. The experimental parameters of the method such as microextraction time, temperature, NaBH{sub 4} concentration, acceptor phase concentration, and pH of the medium were investigated to obtain distinctive conditions for mercury species. Possible interference effects have also been investigated. In order to validation of the method, analytical figures of merits such as accuracy, precision, limit of detection (LOD), limit of quantitation (LOQ), and linear working range have been evaluated. Accuracy of the method has been verified by analyzing certified reference materials (BCR 453 Tuna fish) and spiked samples. The proposed method was applied for the speciation and determination of mercury species in water and fish samples. Mercury species (MeHg and iHg) have been determined in the real samples with a relative error less than 10%. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  15. A novel approach to Lab-In-Syringe Head-Space Single-Drop Microextraction and on-drop sensing of ammonia.

    Science.gov (United States)

    Šrámková, Ivana; Horstkotte, Burkhard; Sklenářová, Hana; Solich, Petr; Kolev, Spas D

    2016-08-31

    A novel approach to the automation technique Lab-In-Syringe, also known as In-Syringe Analysis, is proposed which utilizes a secondary inlet into the syringe void, used as a size-adaptable reaction chamber, via a channel passing through the syringe piston. This innovative approach allows straightforward automation of head-space single-drop microextraction, involving accurately controlled drop formation and handling, and the possibility of on-drop analyte quantification. The syringe was used in upside-down orientation and in-syringe magnetic stirring was carried out, which allowed homogenous mixing of solutions, promotion of head-space analyte enrichment, and efficient syringe cleaning. The superior performance of the newly developed system was illustrated with the development of a sensitive method for total ammonia determination in surface waters. It is based on head-space extraction of ammonia into a single drop of bromothymol blue indicator created inside the syringe at the orifice of the syringe piston channel and on-drop sensing of the color change via fiber optics. The slope of the linear relationship between absorbance and time was used as the analytical signal. Drop formation and performance of on-drop monitoring was further studied with rhodamine B solution to give a better understanding of the system's performance. A repeatability of 6% RSD at 10 μmol L(-1) NH3, a linear range of up to 25 μmol L(-1) NH3, and a limit of detection of 1.8 μmol L(-1) NH3 were achieved. Study of interferences proved the high robustness of the method towards humic acids, high sample salinity, and the presence of detergents, thus demonstrating the method superiority compared to the state-of-the-art gas-diffusion methods. A mean analyte recovery of 101.8% was found in analyzing spiked environmental water samples.

  16. Rapid analysis of Fructus forsythiae essential oil by ionic liquids-assisted microwave distillation coupled with headspace single-drop microextraction followed by gas chromatography–mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Jiao, Jiao [State Key Laboratory of Tree Genetics and Breeding, Northeast Forestry University, Harbin 150040 (China); Ma, Dan-Hui [College of Life Sciences, Northeast Forestry University, Harbin 150040 (China); Gai, Qing-Yan; Wang, Wei; Luo, Meng [State Engineering Laboratory of Bio-Resource Eco-Utilization, Northeast Forestry University, Harbin 150040 (China); Fu, Yu-Jie, E-mail: yujie_fu2002@yahoo.com [State Engineering Laboratory of Bio-Resource Eco-Utilization, Northeast Forestry University, Harbin 150040 (China); Ma, Wei, E-mail: mawei@hljucm.net [State Key Laboratory of Tree Genetics and Breeding, Northeast Forestry University, Harbin 150040 (China); School of Pharmaceutical, Heilongjiang University of Chinese Medicine, Harbin 150040 (China)

    2013-12-04

    Graphical abstract: -- Highlights: •A new ILAMD-HS-SDME method is developed for the microextraction of essential oil. •ILs used as destruction agent of plant cell walls and microwave absorption medium. •Parameters affecting the extraction efficiency are optimized by Box–Behnken design. •Procedure benefits: similar constituents, shorter duration and smaller sample amount. •ILAMD-HS-SDME followed by GC–MS is a promising technique in analytical fields. -- Abstract: A rapid, green and effective miniaturized sample preparation and analytical technique, i.e. ionic liquids-assisted microwave distillation coupled with headspace single-drop microextraction (ILAMD-HS-SDME) followed by gas chromatography–mass spectrometry (GC–MS) was developed for the analysis of essential oil (EO) in Fructus forsythiae. In this work, ionic liquids (ILs) were not only used as the absorption medium of microwave irradiation but also as the destruction agent of plant cell walls. 1-Ethyl-3-methylimidazolium acetate ([C{sub 2}mim]OAc) was chosen as the optimal ILs. Moreover, n-heptadecane (2.0 μL) was selected as the appropriate suspended solvent for the extraction and concentration of EO. Extraction conditions of the proposed method were optimized using the relative peak area of EO constituents as the index, and the optimal operational parameters were obtained as follows: irradiation power (300 W), sample mass (0.7 g), mass ratio of ILs to sample (2.4), temperature (78 °C) and time (3.4 min). In comparison to previous reports, the proposed method was faster and required smaller sample amount but could equally monitor all EO constituents with no significant differences.

  17. Ionic-liquid-assisted microwave distillation coupled with headspace single-drop microextraction followed by GC-MS for the rapid analysis of essential oil in Dryopteris fragrans.

    Science.gov (United States)

    Jiao, Jiao; Gai, Qing-Yan; Wang, Wei; Luo, Meng; Zhao, Chun-Jian; Fu, Yu-Jie; Ma, Wei

    2013-12-01

    A rapid, green and effective miniaturized sample preparation technique, ionic-liquid-assisted microwave distillation coupled with headspace single-drop microextraction was developed for the extraction of essential oil from dried Dryopteris fragrans. 1-Ethyl-3-methylimidazolium acetate was the optimal ionic liquid as the destruction agent of plant cell walls and microwave absorption was medium. n-Heptadecane (2.0 μL) was adopted as the suspended microdrop solvent in the headspace for the extraction and concentration of essential oil. The optimal parameters of the proposed method were an irradiation power of 300 W, sample mass of 0.9 g, mass ratio of ionic liquids to sample of 2.8, extraction temperature of 79°C, and extraction time of 3.6 min. In comparison to the previous reports, the proposed technique could equally monitor all the essential oil components with no significant differences in a simple way, which was more rapid and required a much lower amount of sample. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Ultrasonic nebulization extraction coupled with headspace single-drop microextraction of volatile and semivolatile compounds from the seed of Cuminum cyminum L.

    Science.gov (United States)

    Zhang, Huihui; Shi, Yuhua; Wei, Shigang; Wang, Yinghua; Zhang, Hanqi

    2011-08-15

    Ultrasonic nebulization extraction (UNE) coupled with headspace single-drop microextraction (HS-SDME) was developed. In the UNE process, the analytes were transferred from the aqueous phase to the gas phase. Then the analytes were transferred from the gas phase to the solvent phase by the carrier gas and extracted and enriched with suspended microdrop solvent. Finally, the microdrop solvent injected into GC-MS system. The parameters affecting extraction performance, such as type of suspended solvent, microdrop volume, flow rate of carrier gas, temperature of extraction vessel and extraction time were investigated and optimized. The proposed method can be applied for the extraction and enrichment of the volatile and semivolatile compounds simultaneously. The extraction efficiency of the proposed method was compared with that of ultrasonic extraction (UE) and UE-HS-SDME. Compared with UE-HS-SDME, the contents of constituents in the extract obtained by the proposed method were closer to those obtained by hydrodistillation (HD), which is a standard extraction method.

  19. Direct determination of 2,4,6-tricholoroanisole in wines by single-drop ionic liquid microextraction coupled with multicapillary column separation and ion mobility spectrometry detection.

    Science.gov (United States)

    Márquez-Sillero, Isabel; Cárdenas, Soledad; Valcárcel, Miguel

    2011-10-21

    This article evaluates the capability of single drop ionic liquid microextraction coupled with multicapillary column (MCC) and ion mobility spectrometry (IMS) for the determination of 2,4,6-trichloroanisole (2,4,6-TCA) in wines. The proposed methodology permits the direct analysis of the samples without any additional treatment other than dilution. This is achieved thanks to the selectivity provided by the ionic liquid selected as extractant, 1-hexyl-3-methylimidazolium bis(trifluoromethylsulfonyl)-imide, as well as the response of the analyte in the IMS working in negative ionization mode. Moreover, the multicapillary column avoids the interference of ethanol in the ion mobility spectra. The analysis of the sample takes ca. 35 min to be completed. The limit of detection was low as 0.01 ng L(-1) using 2 mL of wine sample. Different calibration curves were constructed using aqueous standards, red and white wines, being the signals comparable, with an RSD similar to the method variability. Finally, a set of samples of different nature and packed in different containers were analysed. It was found than those with cork stoppers presented the highest concentration of 2,4,6-TCA.

  20. Headspace-Single Drop Microextraction Followed by Gas Chromatographic Determination of Key Aroma Compounds in Tomato Fruits and Their Sample Products

    Directory of Open Access Journals (Sweden)

    Vinita sawaddipanich

    2016-06-01

    Full Text Available A headspace-single drop microextraction (HS-SDME is a good choice to analyze volatile and semivolatile compounds in different matrices without any interference of the sample matrix. HS-SDME spends a very little solvent consumption for the determination of volatile aroma compounds (VACs. In this study, some VACs including 2-methylbutyraldehyde, 3-methyl-1-butanol, sec-butyl acetate, 1-octen-3-one and trans,trans-2,4-decadienal were performed with hexadecane as extraction solvent. The parameters affecting the HS-SDME method were investigated in details including extraction temperature, enrichment time, extraction time and sample volume. The optimum conditions were consisted of 45oC extraction temperature, 15min enrichment, 20min extraction time and 3mL sample volume. Comparison between liquid-liquid extraction (LLE and HS-SDME for quantitative analysis was carried out using tert-butanol as an internal standard. From results revealed that the recoveries were obtained between 81.06-90.55% for LLE and 80.26-90.09% for HS-SDME. The results demonstrated that the proposed method could be successfully applied for the determination of VACs.

  1. Ultrasonic nebulization extraction coupled with headspace single drop microextraction and gas chromatography-mass spectrometry for analysis of the essential oil in Cuminum cyminum L.

    Science.gov (United States)

    Wang, Lu; Wang, Ziming; Zhang, Huihui; Li, Xueyuan; Zhang, Hanqi

    2009-08-04

    A novel method for analysis of essential oil in Cuminum cyminum L. using simultaneous ultrasonic nebulization extraction and headspace single drop microextraction (UNE-HS-SDME) followed by gas chromatography-mass spectrometry was developed. Experimental parameters, including the kind of suspended solvent, microdrop volume, sample amount, extraction time, enrichment time and salt concentration were examined and optimized. Compared with hydrodistillation (HD), UNE-HS-SDME provides the advantages of a small amount of sample (50 mg), time-saving (20 min), simplicity, cheapness and low toxicity. In addition, UNE-HS-SDME also provided higher enrichment efficiency and sensitivity compared with stirring extraction (SE)-HS-SDME, ultrasonic assistant extraction (UAE) and UNE. Some constituents in the essential oil, were identified and the detection limits for beta-pinene, p-cymene and gamma-terpinene range from 6.67 pLL(-1) to 14.8 pLL(-1). The results indicated that the UNE-HS-SDME is simple and highly efficient extraction and enrichment technique.

  2. Rapid analysis of Fructus forsythiae essential oil by ionic liquids-assisted microwave distillation coupled with headspace single-drop microextraction followed by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Jiao, Jiao; Ma, Dan-Hui; Gai, Qing-Yan; Wang, Wei; Luo, Meng; Fu, Yu-Jie; Ma, Wei

    2013-12-04

    A rapid, green and effective miniaturized sample preparation and analytical technique, i.e. ionic liquids-assisted microwave distillation coupled with headspace single-drop microextraction (ILAMD-HS-SDME) followed by gas chromatography-mass spectrometry (GC-MS) was developed for the analysis of essential oil (EO) in Fructus forsythiae. In this work, ionic liquids (ILs) were not only used as the absorption medium of microwave irradiation but also as the destruction agent of plant cell walls. 1-Ethyl-3-methylimidazolium acetate ([C2mim]OAc) was chosen as the optimal ILs. Moreover, n-heptadecane (2.0 μL) was selected as the appropriate suspended solvent for the extraction and concentration of EO. Extraction conditions of the proposed method were optimized using the relative peak area of EO constituents as the index, and the optimal operational parameters were obtained as follows: irradiation power (300 W), sample mass (0.7 g), mass ratio of ILs to sample (2.4), temperature (78°C) and time (3.4 min). In comparison to previous reports, the proposed method was faster and required smaller sample amount but could equally monitor all EO constituents with no significant differences.

  3. Headspace single-drop microextraction and fibre optics-based cuvetteless micro-spectrophotometry for the determination of chloride involving oxidation with permanganate.

    Science.gov (United States)

    Pillai, Aradhana K K V; Jain, Archana; Verma, Krishna K

    2010-03-15

    Headspace single-drop microextraction has been investigated for the determination of chloride in conjunction with fibre optic-based cuvetteless micro-spectrophotometry which accommodates sample volume of 1 microL placed between the two ends of optical fibres. Method has been evolved for the determination of 0.025-4 mg L(-1) of chloride involving its oxidation with permanganate in sulphuric acid medium, and reaction of chlorine with 2 microL drop of starch-iodide reagent suspended at the tip of microsyringe needle in the headspace of the reaction mixture. The limit of detection was found to be 2.8 microg L(-1) of chloride which was better than obtained by existing methods. The method was highly selective and a number of ions which interfered severely in other methods did not affect the results. The method has been used to analyze water samples, inorganic compounds and cement when the overall recovery of chloride was 94.9% with a relative standard deviation of 3.9%.

  4. Preconcentration of thallium (I) by single drop microextraction with electrothermal atomic absorption spectroscopy detection using dicyclohexano-18-crown-6 as extractant system.

    Science.gov (United States)

    Chamsaz, Mahmoud; Arbab-Zavar, Mohammad Hossien; Darroudi, Abolfazl; Salehi, Thiery

    2009-08-15

    A simple single drop liquid-phase microextraction (SDME) technique, combined with electrothermal atomic absorption spectroscopy (ETAAS) is developed both to preconcentrate and determine thallium (I) ions in aqueous solutions. The ions were transferred from 10.0 ml of aqueous sample (donor phase) containing 0.5 ml of 1% picric acid as the ion-pair agent into a 3 microl microdrop of nitrobenzene (acceptor phase) containing dicyclohexano-18-crown-6 as the complexing agent. The latter will help to improve the extraction efficiency of the analyte. After the ions have been extracted, the acceptor drop was directly injected into a graphite furnace for thallium (I) determination. Several parameters such as the extracting solvent, extraction time, temperature, concentration of picric acid and crown ether, drop volume and stirring rate were examined. Under the optimized experimental conditions, the detection limit (L.O.D.) was 0.7 ng ml(-1). The relative standard deviation for five replicate analysis of 10 ng ml(-1) of thallium (I) was 5.1%. The calibration curve was linear in the range of 3-22 ng ml(-1). The results for determination of thallium in reference material, spiked tap water and seawater demonstrated the accuracy, recovery and applicability of the presented method. The enrichment factor was 50.

  5. Ultrasound-assisted single-drop microextraction for the determination of cadmium in vegetable oils using high-resolution continuum source electrothermal atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Jorge S.; Anunciação, Taiana A. [Departamento de Química Analítica, Instituto de Química, Universidade Federal da Bahia, Campus Universitário de Ondina, Salvador, Bahia 40170-280 (Brazil); Brandão, Geovani C. [Departamento de Química Analítica, Instituto de Química, Universidade Federal da Bahia, Campus Universitário de Ondina, Salvador, Bahia 40170-280 (Brazil); INCT de Energia e Ambiente, Instituto de Química, Universidade Federal da Bahia, Campus Universitário de Ondina, Salvador, Bahia 40170-280 (Brazil); Dantas, Alailson F. [Departamento de Química Analítica, Instituto de Química, Universidade Federal da Bahia, Campus Universitário de Ondina, Salvador, Bahia 40170-280 (Brazil); Lemos, Valfredo A. [Laboratório de Química Analítica (LQA), Universidade Estadual do Sudoeste da Bahia, Campus de Jequié, Jequié, Bahia 45506-191 (Brazil); and others

    2015-05-01

    This work presents an ultrasound-assisted single-drop microextraction procedure for the determination of cadmium in vegetable oils using high-resolution continuum source electrothermal atomic absorption spectrometry. Some initial tests showed that the best extraction efficiency was obtained when using ultrasound instead of mechanical agitation, indicating that acoustic cavitation improved the extraction process. Nitric, hydrochloric and acetic acids were evaluated for use in the extraction process, and HNO{sub 3} gave the best results. A two-level full-factorial design was applied to investigate the best conditions for the extraction of Cd from the oil samples. The influences of the sonication amplitude, time and temperature of the extraction were evaluated. The results of the design revealed that all of the variables had a significant effect on the experimental results. Afterward, a Box–Behnken design was applied to determine the optimum conditions for the determination of cadmium in vegetable oil samples. According to a multivariate study, the optimum conditions were as follows: sonication amplitude of 60%, extraction time of 15 min, extraction temperature of 46 °C and 0.1 mol L{sup −1} HNO{sub 3} as the extractor solution. Under optimized conditions, the developed method allows for the determination of Cd in oil samples with a limit of quantification of 7.0 ng kg{sup −1}. Addition and recovery experiments were performed in vegetable oil samples to evaluate the accuracy of the method, and the recoveries obtained varied from 90% to 115%. The samples were also analyzed after the acid digestion procedure, and the paired t-test (95% confidence level) did not show significant differences from the proposed method. - Highlights: • The determination of cadmium in vegetable oils was developed using UA-SDME. • HR-CS ET-AAS was employed as a detection technique with direct drop sampling. • The procedure allowed for a reduction in the consumption of reagents and

  6. Low-density solvent-based dispersive liquid-liquid microextraction combined with single-drop microextraction for the fast determination of chlorophenols in environmental water samples by high performance liquid chromatography-ultraviolet detection.

    Science.gov (United States)

    Li, Xiaoyi; Xue, Aifang; Chen, Hao; Li, Shengqing

    2013-03-08

    A new format of fast three-phase microextraction by combining low-density solvent-based dispersive liquid-liquid microextraction (DLLME) and single-drop microextraction (SDME) was for the first time developed for the determination of chlorophenols in environmental water samples. The extraction procedure includes a 2 min DLLME pre-extraction and a 10 min SDME back-extraction. A portion of low-density solvent (toluene) was used as organic phase and injected into the aqueous sample (donor phase) with methanol as disperser. The analytes were pre-extracted into the organic phase within 2 min. A thin layer of the organic phase formed on the top of the aqueous phase by a 2 min centrifugation. Then a drop of acceptor solution was introduced into the upper layer and SDME was carried out for the back-extraction. The stirring step typically involved in SDME and LLLME is avoided with the benefit of the high speed and efficiency of DLLME pre-extraction. After extraction, the acceptor drop was withdrawn and directly injected into a high performance liquid chromatography instrument with ultraviolet detection for analysis. Five chlorophenols, 4-chlorophenol, 2-chlorophenol, 2,4-dichlorophenol, 2,4,6-trichlorophenol, and pentachlorophenol, were selected as model compounds for developing and evaluating the method. Factors affecting extraction efficiency were studied, including the organic solvent, the disperser solvent, the composition of donor phase and acceptor phase, the volume of acceptor microdrop, and the extraction time. At optimal conditions, the method showed low detection limit (0.016-0.084 μg/L) for the five chlorophenols, good linearity (from 0.2-250 to 1.0-250 μg/L, depending on the analytes) and repeatability (RSD below 8.2, n=5). The simple, fast, and efficient feature of the proposed method was demonstrated by the analysis of chlorophenols in environmental water samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. The effect of surfactant on headspace single drop microextraction for the determination of some volatile aroma compounds in citronella grass and lemongrass leaves by gas chromatography

    Science.gov (United States)

    A rapid method for the determination of some volatile aromatic compounds (VACs), including citronellal, citronellol, neral, geranial, geraniol, and eugenol in citronella grass and lemongrass leaves, was developed using surfactant as a surface tension modifier while performing headspace single drop m...

  8. Ionic liquid based dispersive liquid-liquid microextraction of aromatic amines in water samples

    Institute of Scientific and Technical Information of China (English)

    Yun Chang Fan; Zheng Liang Hu; Mei Lan Chen; Chao Shen Tu; Yan Zhu

    2008-01-01

    In this work, a new microextraction method termed ionic liquid based dispersive liquid-liquid microextraction (IL-DLLME) was demonstrated for the extraction of 2-methylaniline, 4-chloroaniline, 1-naphthylamine and 4-aminobiphenyl in aqueous matrices. After extraction the ionic liquid (IL) phase was injected directly into the high performance liquid chromatography (HPLC) system for determination. Some parameters that might affect the extraction efficiency were optimized. Under the optimum conditions, good linear relationship, sensitivity and reproducibility were obtained. The limits of detection (LOD, S/N = 3) for the four analytes were in the range of 0.45-2.6 μg L-1. The relative standard deviations (R.S.D., n = 6) were in the range of 6.2-9.8%. This method was applied for the analysis of the real water samples. The recoveries ranged from 93.4 to 106.4%. The main advantages of the method are high speed, high recovery, good repeatability and volatile organic solvent-free.

  9. Determination of pyrethroid pesticides in tomato using ionic liquid-based dispersive liquid-liquid microextraction.

    Science.gov (United States)

    Han, Dandan; Tang, Baokun; Row, Kyung Ho

    2014-03-01

    A sensitive determination method was developed for the analysis of pyrethroid pesticide residues in tomato samples using ionic liquid-based dispersive liquid-liquid microextraction. A hydrophobic ionic liquid (1-butyl-3-methylimidazolium hexafluorophosphate) and acetonitrile were used as the extraction solvent and dispersive solvent, respectively. The following experimental parameters affecting the extraction efficiency were examined: types of extraction solvent and volume of extraction solvent, types of dispersive solvent and volume of dispersive solvent and pH and ion strength of the sample solution. Under the optimum conditions, the extraction recoveries ranged from 83.9 to 96.7%. Moreover, the enrichment factors for esbiothrin, fenpropathrin and cyhalothrin were 42, 48 and 45, respectively. The calibration curves were linear with correlation coefficients ranging from 0.9997 to 0.9999 at concentrations of 0.05-1.5 µg/kg. The relative standard deviation (n = 5) was 1.7-4.5%. The limits of detection for esbiothrin, fenpropathrin and cyhalothrin were 8.1, 9.9 and 14.3 µg/kg, respectively.

  10. Rapid analysis of the essential oil components of dried Zanthoxylum bungeanum Maxim by Fe2O3-magnetic-microsphere-assisted microwave distillation and simultaneous headspace single-drop microextraction followed by GC-MS.

    Science.gov (United States)

    Ye, Qing

    2013-06-01

    In this work, microwave distillation assisted by Fe2 O3 magnetic microspheres (FMMS) and headspace single-drop microextraction were combined, and developed for determination of essential oil compounds in dried Zanthoxylum bungeanum Maxim (ZBM). The FMMS were used as microwave absorption solid medium for dry distillation of dried ZBM. Using the proposed method, isolation, extraction, and concentration of essential oil compounds can be carried out in a single step. The experimental parameters including extraction solvent, solvent volume, microwave power, irradiation time, and the amount of added FMMS, were studied. The optimal analytical conditions were: 2.0 μL decane as the extraction solvent, microwave power of 300 W, irradiation time of 2 min, and the addition of 0.1 g FMMS to ZBM. The method precision was from 4 to 10%. A total of 52 compounds were identified by the proposed method. The conventional steam distillation method was also used for the analysis of essential oil in dried ZBM and only 31 compounds were identified by steam distillation method. It was found that the proposed method is a simple, rapid, reliable, and solvent-free technique for the determination of volatile compounds in Chinese herbs. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Pre-concentration and determination of amitriptyline residues in waste water by ionic liquid based immersed droplet microextraction and HPLC

    Institute of Scientific and Technical Information of China (English)

    M.T. Hamed Mosavian; Z. Es'haghi; N. Razavi; S. Banihashemi

    2012-01-01

    This paper describes a new approach for the determination of amitriptyline in wastewater by ionic liquid based immersed droplet microextraction (IL-IDME) prior to highperformance liquid chromatography with ultraviolet detection. 1-Hexyl-3-methylimidazolium hexafluorophosphate ([C6MIM][PF6]) was used as an ionic liquid. Various factors that affect extraction, such as volume of ionic liquid, stirring rate, extraction time, pH of the aqueous solution and salting effect, were optimized. The optimal conditions were as follows: microextraction time, 10 min; stirring rate, 720 rpm; pH, 11; ionic drop volume, 100 uL; and no sodium chloride addition. In quantitative experiments the method showed linearity in a range from 0.01 to 10 ug/mL, a limit of detection of 0.004 ug/mL and an excellent pre-concentration factor (PF) of 1100. Finally, the method was successfully applied to the determination of amitriptyline in the hospital wastewater samples.

  12. Ionic liquid-based dispersive liquid-liquid microextraction for the determination of formaldehyde in wastewaters and detergents.

    Science.gov (United States)

    Arvand, Majid; Bozorgzadeh, Elahe; Shariati, Shahab; Zanjanchi, Mohammad Ali

    2012-12-01

    Spectrophotometry in combination with ionic liquid-based dispersive liquid-liquid microextraction (DLLME) was applied for the extraction and determination of formaldehyde in real samples. The method is based on the reaction of formaldehyde with methyl acetoacetate in the presence of ammonia. The variation in the absorbance of the reaction product was measured at 375 nm. An appropriate mixture of ethanol (disperser solvent) and ionic liquid, 1-hexyl-3-methylimidazoliumhexafluoro-phosphate [C(6)MIM][PF(6)] (extraction solvent) was rapidly injected into a water sample containing formaldehyde. After extraction, sedimented phase was analyzed by spectrophotometry. Under the optimum conditions, the calibration graph was linear in the range of 0.1-20 ng mL(-1) with the detection limit of 0.02 ng mL(-1) and limit of quantification of 0.08 ng mL(-1) for formaldehyde. The relative standard deviation (RSD%, n = 5) for the extraction and determination of 0.8 ng mL(-1) of formaldehyde in the aqueous samples was 2.5%. The results showed that DLLME is a very simple, rapid, sensitive, and efficient analytical method for the determination of trace amounts of formaldehyde in wastewaters and detergents, and suitable results were obtained.

  13. Pesticide extraction from table grapes and plums using ionic liquid based dispersive liquid-liquid microextraction.

    Science.gov (United States)

    Ravelo-Pérez, Lidia M; Hernández-Borges, Javier; Herrera-Herrera, Antonio V; Rodríguez-Delgado, Miguel Angel

    2009-12-01

    Room temperature ionic liquids (RTILs) have been used as extraction solvents in dispersive liquid-liquid microextraction (DLLME) for the determination of eight multi-class pesticides (i.e. thiophanate-methyl, carbofuran, carbaryl, tebuconazole, iprodione, oxyfluorfen, hexythiazox, and fenazaquin) in table grapes and plums. The developed method involves the combination of DLLME and high-performance liquid chromatography with diode array detection. Samples were first homogenized and extracted with acetonitrile. After evaporation and reconstitution of the extract in water containing sodium chloride, a quick DLLME procedure that used the ionic liquid 1-hexyl-3-methylimidazolium hexafluorophosphate ([C(6)MIM][PF(6)]) and methanol was developed. The RTIL dissolved in a very small volume of acetonitrile was directed injected in the chromatographic system. The comparison between the calibration curves obtained from standards and from spiked sample extracts (matrix-matched calibration) showed the existence of a strong matrix effect for most of the analyzed pesticides. A recovery study was also developed with five consecutive extractions of the two types of fruits spiked at three concentration levels. Mean recovery values were in the range of 72-100% for table grapes and 66-105% for plum samples (except for thiophanate-methyl and carbofuran, which were 64-75% and 58-66%, respectively). Limits of detection (LODs) were in the range 0.651-5.44 microg/kg for table grapes and 0.902-6.33 microg/kg for plums, representing LODs below the maximum residue limits (MRLs) established by the European Union in these fruits. The potential of the method was demonstrated by analyzing 12 commercial fruit samples (six of each type).

  14. Ionic liquid based dispersive liquid-liquid microextraction for the extraction of pesticides from bananas.

    Science.gov (United States)

    Ravelo-Pérez, Lidia M; Hernández-Borges, Javier; Asensio-Ramos, María; Rodríguez-Delgado, Miguel Angel

    2009-10-23

    This paper describes a dispersive liquid-liquid microextraction (DLLME) procedure using room temperature ionic liquids (RTILs) coupled to high-performance liquid chromatography with diode array detection capable of quantifying trace amounts of eight pesticides (i.e. thiophanate-methyl, carbofuran, carbaryl, tebuconazole, iprodione, oxyfluorfen, hexythiazox and fenazaquin) in bananas. Fruit samples were first homogenized and extracted (1g) with acetonitrile and after suitable evaporation and reconstitution of the extract in 10 mL of water, a DLLME procedure using 1-hexyl-3-methylimidazolium hexafluorophosphate ([C(6)MIM][PF(6)]) as extraction solvent was used. Experimental conditions affecting the DLLME procedure (sample pH, sodium chloride percentage, ionic liquid amount and volume of disperser solvent) were optimized by means of an experimental design. In order to determine the presence of a matrix effect, calibration curves for standards and fortified banana extracts (matrix matched calibration) were studied. Mean recovery values of the extraction of the pesticides from banana samples were in the range of 69-97% (except for thiophanate-methyl and carbofuran, which were 53-63%) with a relative standard deviation lower than 8.7% in all cases. Limits of detection achieved (0.320-4.66 microg/kg) were below the harmonized maximum residue limits established by the European Union (EU). The proposed method, was also applied to the analysis of this group of pesticides in nine banana samples taken from the local markets of the Canary Islands (Spain). To the best of our knowledge, this is the first application of RTILs as extraction solvents for DLLME of pesticides from samples different than water.

  15. Determination of atenolol in human plasma using ionic-liquid-based ultrasound-assisted in situ solvent formation microextraction followed by high-performance liquid chromatography.

    Science.gov (United States)

    Zeeb, Mohsen; Farahani, Hadi; Papan, Mohammad Kazem

    2016-06-01

    An efficient analytical method called ionic-liquid-based ultrasound-assisted in situ solvent formation microextraction followed by high-performance liquid chromatography was developed for the determination of atenolol in human plasma. A hydrophobic ionic liquid (1-butyl-3-methylimidazolium hexafluorophosphate) was formed by the addition of a hydrophilic ionic liquid (1-butyl-3-methylimidazolium tetrafluoroborate) to a sample solution containing an ion-pairing agent during microextraction. The analyte was extracted into the ionic liquid phase while the microextraction solvent was dispersed throughout the sample by utilizing ultrasound. The sample was then centrifuged, and the extracting phase retracted into the microsyringe and injected to liquid chromatography. After optimization, the calibration curve showed linearity in the range of 2-750 ng/mL with the regression coefficient corresponding to 0.998. The limits of detection (S/N = 3) and quantification (S/N = 10) were 0.5 and 2 ng/mL, respectively. A reasonable relative recovery range of 90-96.7% and satisfactory intra-assay (4.8-5.1%, n = 6) and interassay (5.0-5.6%, n = 9) precision along with a substantial sample clean-up demonstrated good performance of the procedure. It was applied for the determination of atenolol in human plasma after oral administration and some pharmacokinetic data were obtained.

  16. Ionic liquid-based dispersive liquid-liquid microextraction and enhanced spectrophotometric determination of molybdenum (VI) in water and plant leaves samples by FO-LADS.

    Science.gov (United States)

    Gharehbaghi, Maysam; Shemirani, Farzaneh

    2011-02-01

    A new simple and rapid ionic liquid-based dispersive liquid-liquid microextraction (IL-DLLME) has been applied to preconcentrate trace levels of molybdenum (VI) as a prior step to its enhanced determination by fiber optic-linear array detection spectrophotometry (FO-LADS). In this method, a small amount of [Hmim][Tf(2)N] (1-hexyl-3-methylimmidazolium bis (trifluormethylsulfonyl) imid) as an extraction solvent was applied to extract molybdenum - pyrogallol red complex, which was formed in an aqueous solution in the presence of N-cetyl-N-N-N-trimethyl ammonium chloride as a sensitizing agent. Under optimum conditions, enhancement factor, detection limit and relative standard deviation (n=5, for 30 μg L(-1) of molybdenum (VI)) in 10 mL water sample were 72.6, 1.43 μg L(-1) and 2.8%, respectively.

  17. Ionic liquid-based ultrasound-assisted emulsification microextraction coupled with high performance liquid chromatography for the determination of four fungicides in environmental water samples.

    Science.gov (United States)

    Liang, Pei; Wang, Fang; Wan, Qin

    2013-02-15

    A highly efficient and environmentally friendly sample preparation method termed ionic liquid-based ultrasound-assisted emulsification microextraction (IL-USAEME) combined with high performance liquid chromatography has been developed for the determination of four fungicides (azoxystrobin, diethofencarb, pyrimethanil and kresoxim-methyl) in water samples. In this novel approach, ionic liquid (IL) was used as extraction solvent in place of the organic solvent used in conventional USAEME assay, and there is no need for using organic dispersive solvent which is typically required in the common dispersive liquid-liquid microextraction method. Various parameters that affect the extraction efficiency, such as the kind and volume of IL, ultrasound emulsification time, extraction temperature and salt addition were investigated and optimized. Under the optimum extraction condition, the linearities of calibration curves were in the range from 3 to 5000 ng mL(-1) for target analytes with the correlation coefficient higher than 0.9992. The enrichment factors and the limits of detection were in the range of 88-137 and 0.73-2.2 ng mL(-1), depending on the analytes. The environmental water samples were successfully analyzed using the proposed method, and the relative recoveries at fortified levels of 50 and 100 ng mL(-1) were in the range of 83.9%-116.2%.

  18. Ionic-liquid-based dispersive liquid-liquid microextraction for high-throughput multiple food contaminant screening.

    Science.gov (United States)

    Ho, Yee-Man; Tsoi, Yeuk-Ki; Leung, Kelvin Sze-Yin

    2013-12-01

    This paper describes an innovation of dispersive liquid-liquid microextraction enabling multiple-component analysis of eight high-priority food contaminants in two chemically distinctive families: Sudan dyes and phthalate plasticizers. To provide convenient sample handling for solid and solid-containing matrices, a modified dispersive liquid-liquid microextraction procedure used an extractant precoated frit to perform simultaneous filtration, solvent mixing, and phase dispersion in one simple step. A binary ionic liquid extractant system was carefully tuned to deliver high quality analysis based only on affordable LC with diode array detector instrumentation. The method is comprehensively validated for robust quantification with good precision (6.9-9.8% RSD) in a linear 2-1000 μg/L range. Having accomplished enrichment factors up to 451, the treatment enables sensitive detection at 0.09-1.01 μg/L levels. Analysis of six high-risk solid condiments and sauces further verified its practical applicability within a 70-120% recovery range. Compared to other approaches, the current dispersive liquid-liquid microextraction treatment offers major advantages in terms of minimal solvent (1.5 mL) and sample (0.1 g) consumption, ultra-high analytical throughput (6 min), and the ability to handle complex solid matrices. The idea of performing simultaneous analysis for multiple contaminants presented here fosters a more effective mode of operation in food control routines.

  19. Highly selective ionic liquid-based microextraction method for sensitive trace cobalt determination in environmental and biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Berton, Paula [Analytical Chemistry Research and Development Group (QUIANID), (LISAMEN - CCT - CONICET - Mendoza), Av. Ruiz Leal S/N Parque General San Martin, M 5502 IRA Mendoza (Argentina); Wuilloud, Rodolfo G., E-mail: rwuilloud@mendoza-conicet.gov.ar [Analytical Chemistry Research and Development Group (QUIANID), (LISAMEN - CCT - CONICET - Mendoza), Av. Ruiz Leal S/N Parque General San Martin, M 5502 IRA Mendoza (Argentina); Instituto de Ciencias Basicas, Universidad Nacional de Cuyo, Mendoza (Argentina)

    2010-03-10

    A simple and rapid dispersive liquid-liquid microextraction procedure based on an ionic liquid (IL-DLLME) was developed for selective determination of cobalt (Co) with electrothermal atomic absorption spectrometry (ETAAS) detection. Cobalt was initially complexed with 1-nitroso-2-naphtol (1N2N) reagent at pH 4.0. The IL-DLLME procedure was then performed by using a few microliters of the room temperature ionic liquid (RTIL) 1-hexyl-3-methylimidazolium hexafluorophosphate [C{sub 6}mim][PF{sub 6}] as extractant while methanol was the dispersant solvent. After microextraction procedure, the Co-enriched RTIL phase was solubilized in methanol and directly injected into the graphite furnace. The effect of several variables on Co-1N2N complex formation, extraction with the dispersed RTIL phase, and analyte detection with ETAAS, was carefully studied in this work. An enrichment factor of 120 was obtained with only 6 mL of sample solution and under optimal experimental conditions. The resultant limit of detection (LOD) was 3.8 ng L{sup -1}, while the relative standard deviation (RSD) was 3.4% (at 1 {mu}g L{sup -1} Co level and n = 10), calculated from the peak height of absorbance signals. The accuracy of the proposed methodology was tested by analysis of a certified reference material. The method was successfully applied for the determination of Co in environmental and biological samples.

  20. Ionic liquid-based ultrasound-assisted dispersive liquid-liquid microextraction combined with electrothermal atomic absorption spectrometry for a sensitive determination of cadmium in water samples

    Energy Technology Data Exchange (ETDEWEB)

    Li Shengqing [Department of Chemistry, College of Science, Huazhong Agricultural University, Wuhan 430070 (China); Supervision, Inspection and Testing Center of Microbial Products Quality (Wuhan), Ministry of Agriculture (China)], E-mail: sqingli@mail.hzau.edu.cn; Cai Shun; Hu Wei [Department of Chemistry, College of Science, Huazhong Agricultural University, Wuhan 430070 (China); Chen Hao [Department of Chemistry, College of Science, Huazhong Agricultural University, Wuhan 430070 (China)], E-mail: hchenhao@mail.hzau.edu.cn; Liu Hanlan [Department of Chemistry, College of Science, Huazhong Agricultural University, Wuhan 430070 (China)

    2009-07-15

    A new method was developed for the determination of cadmium in water samples using ionic liquid-based ultrasound-assisted dispersive liquid-liquid microextraction (IL-based USA-DLLME) followed by electrothermal atomic absorption spectrometry (ETAAS). The IL-based USA-DLLME procedure is free of volatile organic solvents, and there is no need for a dispersive solvent, in contrast to conventional DLLME. The ionic liquid, 1-hexyl-3-methylimidazolium hexafluorophosphate (HMIMPF{sub 6}), was quickly disrupted by an ultrasonic probe for 1 min and dispersed in water samples like a cloud. At this stage, a hydrophobic cadmium-DDTC complex was formed and extracted into the fine droplets of HMIMPF{sub 6}. After centrifugation, the concentration of the enriched cadmium in the sedimented phase was determined by ETAAS. Some effective parameters of the complex formation and microextraction, such as the concentration of the chelating agent, the pH, the volume of the extraction solvent, the extraction time, and the salt effect, have been optimized. Under optimal conditions, a high extraction efficiency and selectivity were reached for the extraction of 1.0 ng of cadmium in 10.0 mL of water solution employing 73 {mu}L of HMIMPF{sub 6} as the extraction solvent. The enrichment factor of the method is 67. The detection limit was 7.4 ng L{sup - 1}, and the characteristic mass (m{sub 0}, 0.0044 absorbance) of the proposed method was 0.02 pg for cadmium (Cd). The relative standard deviation (RSD) for 11 replicates of 50 ng L{sup - 1} Cd was 3.3%. The method was applied to the analysis of tap, well, river, and lake water samples and the Environmental Water Reference Material GSBZ 50009-88 (200921). The recoveries of spiked samples were in the range of 87.2-106%.

  1. Ionic liquid-based ultrasound-assisted dispersive liquid-liquid microextraction combined with electrothermal atomic absorption spectrometry for a sensitive determination of cadmium in water samples

    Science.gov (United States)

    Li, Shengqing; Cai, Shun; Hu, Wei; Chen, Hao; Liu, Hanlan

    2009-07-01

    A new method was developed for the determination of cadmium in water samples using ionic liquid-based ultrasound-assisted dispersive liquid-liquid microextraction (IL-based USA-DLLME) followed by electrothermal atomic absorption spectrometry (ETAAS). The IL-based USA-DLLME procedure is free of volatile organic solvents, and there is no need for a dispersive solvent, in contrast to conventional DLLME. The ionic liquid, 1-hexyl-3-methylimidazolium hexafluorophosphate (HMIMPF 6), was quickly disrupted by an ultrasonic probe for 1 min and dispersed in water samples like a cloud. At this stage, a hydrophobic cadmium-DDTC complex was formed and extracted into the fine droplets of HMIMPF 6. After centrifugation, the concentration of the enriched cadmium in the sedimented phase was determined by ETAAS. Some effective parameters of the complex formation and microextraction, such as the concentration of the chelating agent, the pH, the volume of the extraction solvent, the extraction time, and the salt effect, have been optimized. Under optimal conditions, a high extraction efficiency and selectivity were reached for the extraction of 1.0 ng of cadmium in 10.0 mL of water solution employing 73 µL of HMIMPF 6 as the extraction solvent. The enrichment factor of the method is 67. The detection limit was 7.4 ng L - 1 , and the characteristic mass ( m0, 0.0044 absorbance) of the proposed method was 0.02 pg for cadmium (Cd). The relative standard deviation (RSD) for 11 replicates of 50 ng L - 1 Cd was 3.3%. The method was applied to the analysis of tap, well, river, and lake water samples and the Environmental Water Reference Material GSBZ 50009-88 (200921). The recoveries of spiked samples were in the range of 87.2-106%.

  2. Estimation of lead in biological samples of oral cancer patients chewing smokeless tobacco products by ionic liquid-based microextraction in a single syringe system.

    Science.gov (United States)

    Arain, Sadaf S; Kazi, Tasneem G; Arain, Asma J; Afridi, Hassan I; Arain, Muhammad B; Brahman, Kapil D; Naeemullah; Panhwar, Abdul H; Arain, Mariam S

    2015-08-01

    Several studies have reported that the chewing habit of smokeless tobacco (SLT) has been associated with oral cancer. The aim of the present study was to evaluate the trace levels of lead (Pb) in biological samples (blood, scalp hair) of oral cancer patients and referents of the same age group (range 30-60 years). As the concentrations of Pb are very low in biological samples, so a simple and efficient ionic liquid-based microextraction in a single syringe system has been developed, as a prior step to determination by flame atomic absorption spectrometry. In this procedure, the hydrophobic chelates of Pb with ammonium pyrrolidinedithiocarbamate (APDC) were extracted into fine droplets of 1-butyl-3-methylimidazolium hexafluorophosphate [C4MIM][PF6] within a syringe while using Triton X-114 as a dispersant. Factors influencing the microextraction efficiency and determination, such as pH of the sample, volume of [C4MIM][PF6] and Triton X-114, ligand concentration, and incubation time, were studied. To validate the proposed method, certified reference materials were analyzed and the results of Pb(2+) were in good agreement with certified values. At optimum experimental values of significant variables, detection limit and enhancement factor were found to be 0.412 μg/L and 80, respectively. The coexisting ions showed no obvious negative outcome on Pb preconcentration. The proposed method was applied satisfactorily for the preconcentration of Pb(2+) in acid-digested SLT and biological samples of the study population. It was observed that oral cancer patients who consumed different SLT products have 2-3-fold higher levels of Pb in scalp hair and blood samples as compared to healthy referents (p < 0.001). While 31.4-50.8% higher levels of Pb were observed in referents chewing different SLT products as compared to nonconsumers (p < 0.01).

  3. Determination of Four Pesticides in Soil by Homogeneous Ionic Liquid-based Microextraction Coupled with High-performance Liquid Chromatography

    Institute of Scientific and Technical Information of China (English)

    YAN Rui; SHAO Ming-yuan; LIANG Zhen-fen; ZHANG Han-qi; YU Ai-min

    2013-01-01

    Homogeneous ionic liquid microextraction was developed for the simultaneceus extraction of dimethomorph,mefenacet,isoprothiolane and oxadiazon from soil.1-Butyl-3-methylimidazolium tetrafluoroborate was used as extraction solvent,and ammonium hexafluorophosphate was used as ion-pairing agent.High-performance liquid chromatography(HPLC) was employed for separation and determination of the analytes.The calibration curves show good linear relationship(r>0.9988).The recoveries are between 74.2% and 97.9% with relative standard deviations(RSDs) lower than 5.97%.The present method is free of volatile organic solvents,and expenditures of sample,extraction time and solvent are lower,compared with ultrasonic and Soxhlet extraction.There was no obvious difference in the extraction recoveries of pesticides obtained by the three extraction methods.

  4. Ultrasound-assisted ionic liquid-based homogeneous liquid-liquid microextraction high-performance liquid chromatography for determination of tanshinones in Salvia miltiorrhiza Bge. root.

    Science.gov (United States)

    Wang, Zhibing; Cao, Bocheng; Yu, Aimin; Zhang, Hanqi; Qiu, Fangping

    2015-02-01

    The ultrasound-assisted ionic liquid-based homogeneous liquid-liquid microextraction has been developed and applied to the extraction of four tanshinones, including dihydrotanshinone, tanshinone I, cryptotanshinone and tanshinone IIA in Salvia miltiorrhiza Bge. root. High performance liquid chromatography was applied to the separation and determination of the analytes. The ionic liquid was used as extraction solvent and target analytes were extracted with help of ultrasound. Then, ion-pairing agent was added into the sample solution, which resulted in the formation of water-insoluble ionic liquid in the solution. The phase separation was performed by centrifugation. The extraction, concentration and purification of target analytes were performed simultaneously. The experimental parameters, including type and volume of ionic liquid, sample amount, the size of sample particle, pH value of extraction medium, extraction temperature, extraction time, amount of ion-pairing agent and centrifuging time, were investigated and optimized. The calibration curves showed good linear relationship (r>0.9997). The limits of detection and quantification were in the range of 0.052-0.093 and 0.17-0.31 μg mL(-1), respectively. The recoveries were between 70.45% and 94.23% with relative standard deviations lower than 5.31%. The present method is free of volatile organic solvents, and represents lower expenditures of sample, extraction time and solvent, compared with UAE and HRE. There was no obvious difference in the extraction yields of active constitutions obtained by the three extraction methods.

  5. Ionic Liquid-based Microwave-assisted Liquid-liquid Microextraction and High Performance Liquid Chromatography Determination of Sulfonamides from Animal Oils

    Institute of Scientific and Technical Information of China (English)

    FENG Xu-dong; LIANG Fang-hui; SU Rui; WU Li-jie; LI Xue-yuan; WANG Xing-hua; ZHANG Han-qi

    2013-01-01

    The authors performed ionic liquid-based microwave-assisted liquid-liquid microextraction(IL-based MALLME) coupled with high performance liquid chromatographic separation for the determination of 6 sulfonamides (SAs) from animal oils.The target analytes were extracted from animal oil samples with sodium hydroxide solution containing 1-butyl-3-methylimidazolium tetrafluoroborateand as the extraction solvent under microwave irradiation.The experimental parameters of the IL-based MALLME,including types of ILs,volume of IL,amount of ion-pairing agent(NH4PF6),pH value of sample solution,and extraction temperature and time were evaluated.The limits of detection and quantification obtained were in a range of 0.4-0.5 μg/kg and a range of 1.2-1.8 μg/kg,respectively.The accuracy of the method was evaluated by analyzing five spiked animal oil samples at two fortified levels(5 and 50 μg/kg),and the recoveries of SAs varied from 81.4% to 114.5% with relative standard deviations ranging from 0.8% to 9.0%.

  6. Ultrasonic characterization of single drops of liquids

    Energy Technology Data Exchange (ETDEWEB)

    Sinha, Dipen N. (Los Alamos, NM)

    1998-01-01

    Ultrasonic characterization of single drops of liquids. The present invention includes the use of two closely spaced transducers, or one transducer and a closely spaced reflector plate, to form an interferometer suitable for ultrasonic characterization of droplet-size and smaller samples without the need for a container. The droplet is held between the interferometer elements, whose distance apart may be adjusted, by surface tension. The surfaces of the interferometer elements may be readily cleansed by a stream of solvent followed by purified air when it is desired to change samples. A single drop of liquid is sufficient for high-quality measurement. Examples of samples which may be investigated using the apparatus and method of the present invention include biological specimens (tear drops; blood and other body fluid samples; samples from tumors, tissues, and organs; secretions from tissues and organs; snake and bee venom, etc.) for diagnostic evaluation, samples in forensic investigations, and detection of drugs in small quantities.

  7. Fabrication of a polymeric ionic liquid-based adsorbent for multiple monolithic fiber solid-phase microextraction of endocrine disrupting chemicals in complicated samples.

    Science.gov (United States)

    Pei, Miao; Zhang, Zirui; Huang, Xiaojia; Wu, Yuanfei

    2017-04-01

    A multiple monolithic fiber solid-phase microextraction (MMF-SPME) utilizing polymeric ionic liquid-based adsorbent was prepared. The adsorbent was obtained by in situ copolymerization of an ionic liquid, 1-trimethyl-(4-vinylbenzyl) aminium chloride and dual cross-linkers (divinylbenzene and ethylenedimethacrylate). The effect of preparation conditions including the content of ionic liquid and porogen in the polymerization mixture on extraction performance was studied in detail. Infrared spectroscopy, elemental analysis, scanning electron microscopy and mercury intrusion porosimetry were used to inspect the physicochemical properties of the new adsorbent. The applicability of the new MMF-SPME was demonstrated by the extraction of trace endocrine disrupting chemicals (EDCs). Results indicated that the prepared MMF-SPME could extract EDCs effectively through multi-interactions such as ion-exchange, π-π and hydrophobic interactions. After optimization of extraction parameters, a method of MMF-SPME coupled to high performance liquid chromatography/diode array detection was conducted to detect trace EDCs in complicated samples including environmental water and human urine. The limits of detection (S/N=3) and quantification (S/N=10) for targeted compounds were 0.011-0.065μg/L and 0.036-0.21μg/L, respectively. Satisfactory precision was also achieved by evaluating the repeatability and intermediate precision with relative standard deviations (RSDs) of less than 9% and 10%, respectively. At the same time, the proposed method was successfully applied for the determination of EDCs in water and human urine with spiking recoveries ranged from 70.6% to 119%.

  8. Simultaneous multicomponent spectrophotometric monitoring of methyl and propyl parabens using multivariate statistical methods after their preconcentration by robust ionic liquid-based dispersive liquid-liquid microextraction

    Science.gov (United States)

    Khani, Rouhollah; Ghasemi, Jahan B.; Shemirani, Farzaneh

    2014-03-01

    A powerful and efficient signal-preprocessing technique that combines local and multiscale properties of the wavelet prism with the global filtering capability of orthogonal signal correction (OSC) is applied for pretreatment of spectroscopic data of parabens as model compounds after their preconcentration by robust ionic liquid-based dispersive liquid-liquid microextraction method (IL-DLLME). In the proposed technique, a mixture of a water-immiscible ionic liquid (as extraction solvent) [Hmim][PF6] and disperser solvent is injected into an aqueous sample solution containing one of the IL's ions, NaPF6, as extraction solvent and common ion source. After preconcentration, the absorbance of the extracted compounds was measured in the wavelength range of 200-700 nm. The wavelet orthogonal signal correction with partial least squares (WOSC-PLS) method was then applied for simultaneous determination of each individual compound. Effective parameters, such as amount of IL, volume of the disperser solvent and amount of NaPF6, were inspected by central composite design to identify the most important parameters and their interactions. The effect of pH on the sensitivity and selectivity was studied according to the net analyte signal (NAS) for each component. Under optimum conditions, enrichment factors of the studied compounds were 75 for methyl paraben (MP) and 71 for propyl paraben (PP). Limits of detection for MP and PP were 4.2 and 4.8 ng mL-1, respectively. The root mean square errors of prediction for MP and PP were 0.1046 and 0.1275 μg mL-1, respectively. The practical applicability of the developed method was examined using hygienic, cosmetic, pharmaceutical and natural water samples.

  9. Multiple functional ionic liquids based dispersive liquid-liquid microextraction combined with high performance chromatography for the determination of phenolic compounds in water samples.

    Science.gov (United States)

    Sun, Jian-Nan; Chen, Juan; Shi, Yan-Ping

    2014-07-01

    A new mode of ionic liquid based dispersive liquid-liquid microextraction (IL-DLLME) is developed. In this work, [C6MIm][PF6] was chosen as the extraction solvent, and two kinds of hydrophilic ionic liquids, [EMIm][BF4] and [BSO3HMIm][OTf], functioned as the dispersive solvent. So in the whole extraction procedure, no organic solvent was used. With the aid of SO3H group, the acidic compound was extracted from the sample solution without pH adjustment. Two phenolic compounds, namely, 2-naphthol and 4-nitrophenol were chosen as the target analytes. Important parameters affecting the extraction efficiency, such as the type of hydrophilic ionic liquids, the volume ratio of [EMIm][BF4] to [BSO3HMIm][OTf], type and volume of extraction solvent, pH value of sample solution, sonication time, extraction time and centrifugation time were investigated and optimized. Under the optimized extraction conditions, the method exhibited good sensitivity with the limits of detection (LODs) at 5.5 μg L(-1)and 10.0 μg L(-1) for 4-nitrophenol and 2-naphthol, respectively. Good linearity over the concentration ranges of 24-384 μg L(-1) for 4-nitrophenol and 28-336 μg L(-1) for 2-naphthol was obtained with correlation coefficients of 0.9998 and 0.9961, respectively. The proposed method can directly extract acidic compound from environmental sample or even more complex sample matrix without any pH adjustment procedure.

  10. Determination of metal ions in tea samples using task-specific ionic liquid-based ultrasound-assisted dispersive liquid-liquid microextraction coupled to liquid chromatography with ultraviolet detection.

    Science.gov (United States)

    Werner, Justyna

    2016-04-01

    Task-specific ionic liquid-based ultrasound-assisted dispersive liquid-liquid microextraction was used for the preconcentration of cadmium(II), cobalt(II), and lead(II) ions in tea samples, which were subsequently analyzed by liquid chromatography with UV detection. The proposed method of preconcentration is free of volatile organic compounds, which are often used as extractants and dispersing solvents in classic techniques of microextraction. A task-specific ionic liquid trioctylmethylammonium thiosalicylate was used as an extractant and a chelating agent. Ultrasound was used to disperse the ionic liquid. After microextraction, the phases were separated by centrifugation, and the ionic liquid phase was solubilized in methanol and directly injected into the liquid chromatograph. Selected microextraction parameters, such as the volume of ionic liquid, the pH of the sample, the duration of ultrasound treatment, the speed and time of centrifugation, and the effect of ionic strength, were optimized. Under optimal conditions an enrichment factor of 200 was obtained for each analyte. The limits of detection were 0.002 mg/kg for Cd(II), 0.009 mg/kg for Co(II), and 0.013 mg/kg for Pb(II). The accuracy of the proposed method was evaluated by an analysis of the Certified Reference Materials (INCT-TL-1, INCT-MPH-2) with the recovery values in the range of 90-104%.

  11. Development of a robust ionic liquid-based dispersive liquid-liquid microextraction against high concentration of salt for preconcentration of trace metals in saline aqueous samples: Application to the determination of Pb and Cd

    Energy Technology Data Exchange (ETDEWEB)

    Yousefi, Seyed Reza [School of Chemistry, University College of Science, University of Tehran, Tehran (Iran, Islamic Republic of); Shemirani, Farzaneh, E-mail: shemiran@khayam.ut.ac.ir [School of Chemistry, University College of Science, University of Tehran, Tehran (Iran, Islamic Republic of)

    2010-06-11

    A new ionic liquid-based dispersive liquid-liquid microextraction method was developed for preconcentration and determination of compounds in aqueous samples containing very high salt concentrations. This method can solve the problems associated with the limited application of the conventional IL-based DLLME in these samples. This is believed to arise from dissolving of the ionic liquids in aqueous samples with high salt content. In this method, the robustness of microextraction system against high salt concentration (up to 40%, w/v) is increased by introducing a common ion of the ionic liquid into the sample solution. The proposed method was applied satisfactorily to the preconcentration of lead and cadmium in saline samples. After preconcentration, the settled IL-phase was dissolved in 100 {mu}L ethanol and aspirated into the flame atomic absorption spectrometer (FAAS) using a home-made microsample introduction system. Several variables affecting the microextraction efficiency were investigated and optimized. Under the optimized conditions and preconcentration of only 10 mL of sample, the enhancement factors of 273 and 311 and the detection limits of 0.6 {mu}g L{sup -1} and 0.03 {mu}g L{sup -1} were obtained for lead and cadmium, respectively. Validation of the method was performed by both an analysis of a certified reference material (CRM) and comparison of results with those obtained by ISO standard method.

  12. Separation-preconcentration of nickel and lead in food samples by a combination of solid-liquid-solid dispersive extraction using SiO2 nanoparticles, ionic liquid-based dispersive liquid-liquid micro-extraction.

    Science.gov (United States)

    Jalbani, Nusrat; Soylak, Mustafa

    2015-01-01

    A microextraction method for the determination of nickel and lead using solid-liquid-solid dispersive extraction followed by ionic liquid-based dispersive liquid-liquid microextraction (SLSDE-ILDLLME) was presented. It was applied to the extraction of nickel and lead from food samples. Ammonium pyrrolidine dithiocarbamate (APDC) as complexing agent, [C4MIM][PF6] as ionic liquid, SiO2 as nanoparticles and 2 mol L(-1) HNO3 as eluent were used. Several important parameters such as amount of IL, extraction time, pH and volume of the complexing agent were investigated. The quantitative recoveries were obtained at pH 7.0 for analytes. Under the optimum conditions, the limits of detection (LODs) calculated using 3(Sd)blank/m were 0.17 for Ni(II) and 0.79 µg L(-1) for Pb(II) for aqueous solutions with 125 enrichment factor (EF). The limit of detections of the analyte ions (3(Sd)blank/m) for solid samples were 0.09 µg g(-1) (Ni) and 0.40 µg g(-1) (Pb). The accuracy of the proposed method was confirmed by the analysis of standard reference material (1577c bovine liver) and spiked recovery test. The proposed method was applied to determine nickel and lead levels in chicken, fish and meat samples.

  13. Room temperature ionic liquid-based microextraction for vanadium species separation and determination in water samples by electrothermal atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Berton, Paula; Martinis, Estefania M. [Laboratory of Environmental Research and Services of Mendoza (LISAMEN), (CCT-CONICET-Mendoza), Av. Ruiz Leal S/N Parque General San Martin, CC. 131, M 5502 IRA Mendoza (Argentina); Martinez, Luis D. [INQUISAL-CONICET, Departamento de Quimica Analitica, Facultad de Quimica, Bioquimica y Farmacia, Universidad Nacional de San Luis (Argentina); Wuilloud, Rodolfo G., E-mail: rwuilloud@mendoza-conicet.gov.ar [Laboratory of Environmental Research and Services of Mendoza (LISAMEN), (CCT-CONICET-Mendoza), Av. Ruiz Leal S/N Parque General San Martin, CC. 131, M 5502 IRA Mendoza (Argentina); Instituto de Ciencias Basicas, Universidad Nacional de Cuyo, Mendoza (Argentina)

    2009-04-27

    A simple microextraction technique based on room temperature ionic liquids (RTILs) for trace V(IV) and V(V) species separation and preconcentration in water samples was developed in this work. Vanadium species microextraction was achieved with a minimal amount of the RTIL 1-butyl-3-methylimidazolium hexafluorophosphate ([C{sub 4}mim][PF{sub 6}]) as vanadium-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (V-5-Br-PADAP) complex. The speciation analysis was performed based on a modern technique defined as temperature-controlled ionic liquid dispersive liquid phase microextraction (TILDLME). The level of V(IV) species was calculated by difference of total V and V(V) levels. Selectivity among V species was obtained with the use of 1,2-cyclohexanediaminetetraacetic acid (CDTA) as masking agent. Determination of V was developed by direct injection of the RTIL phase into the electrothermal atomic absorption spectrometer (ETAAS). A preconcentration factor of 40 was achieved with only 2 mL of sample. The limit of detection (LOD) obtained under optimum conditions was 4.9 ng L{sup -1} and the relative standard deviation for 10 replicate determinations at the 0.5 {mu}g L{sup -1} V level was 4.3%, calculated at peak heights. A correlation coefficient of 0.9961 was achieved. The method was successfully applied for the speciation analysis of V in tap and river water samples.

  14. Ionic liquid-based totally organic solvent-free emulsification microextraction coupled with high performance liquid chromatography for the determination of three acaricides in fruit juice.

    Science.gov (United States)

    Zhang, Jiaheng; Liang, Zhe; Guo, Hao; Gao, Peng; Lu, Runhua; Zhou, Wenfeng; Zhang, Sanbing; Gao, Haixiang

    2013-10-15

    A novel, totally organic solvent-free emulsification microextraction (TEME) technique using ionic liquids (ILs) is proposed in this study. Seven bis(trifluoromethylsulfonyl)imide ionic liquids were synthesized. After comparing the physicochemical properties of the ionic liquids and their application to microextraction experiments, 1-hexyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide ([C6MIM][NTf2]), which has moderate surface tension and viscosity, was selected as the extraction solvent. The dispersion of ILs and mass transfer were accelerated by ultrasound irradiation and temperature control processes. Therefore, no dispersive organic solvent was needed. Several variables, such as ionic liquid volume, duration of the ultrasound extraction, dispersion temperature, ionic strength and centrifugation time were investigated and optimized. Under the optimum conditions, the calibration curve was linear in the range of 0.1-600 μg L(-1) for chlorfenapyr and fenpyroximate and 0.5-600 μg L(-1) for spirodiclofen, with correlation coefficients of 0.9994-0.9999. The enrichment factors were between 261 and 285. The limits of detection (LODs) were 0.02-0.06 μg L(-1). Real fruit juice samples (at fortified levels of 10 μg L(-1) and 30 μg L(-1)) were successfully analyzed using the proposed method. The relative recoveries and enrichment factors were in the range of 92-104%. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. [Determination of five triazine herbicides in infant milk powder by high performance liquid chromatography coupled with ionic liquid-based homogeneous liquid-liquid microextraction].

    Science.gov (United States)

    Zhang, Liyuan; Yao, Di; Li, Na; Zhang, Hanqi; Yu, Aimin

    2015-07-01

    A high performance liquid chromatography coupled with homogeneous liquid-liquid microextraction was developed for the determination of five triazine herbicides in infant milk powders. The ionic liquid was used as microextraction solvent. The separation of the herbicides was performed on an Eclipse XDB-C18 column using acetonitrile and water as mobile phases in gradient mode. The effects of homogeneous liquid-liquid extraction conditions on the experimental results were investigated in detail. Under the optimized experimental conditions, the calibration curves for determining the analytes were linear and the correlation coefficients were ≥ 0.9992. The limits of detection for cyanazine, desmetryn, terbumeton, terbuthylazine and dimethametryn were 12.1, 13.8, 11.8, 14.6 and 13.7 μg/kg, respectively. The recoveries of the analytes spiked in four infant milk powders ranged from 92.2% to 103.2% and the relative standard deviations were lower than 6%. This method is sensitive, simple, and suitable for the determination of triazine herbicides in milk powder samples.

  16. Ionic liquid-based zinc oxide nanofluid for vortex assisted liquid liquid microextraction of inorganic mercury in environmental waters prior to cold vapor atomic fluorescence spectroscopic detection.

    Science.gov (United States)

    Amde, Meseret; Liu, Jing-Fu; Tan, Zhi-Qiang; Bekana, Deribachew

    2016-01-01

    Zinc oxide nanofluid (ZnO-NF) based vortex assisted liquid liquid microextraction (ZnO-NF VA-LLME) was developed and employed in extraction of inorganic mercury (Hg(2+)) in environmental water samples, followed by cold vapor atomic fluorescence spectrometry (CV-AFS). Unlike other dispersive liquid liquid microextraction techniques, ZnO-NF VA-LLME is free of volatile organic solvents and dispersive solvent consumption. Analytical signals were obtained without back-extraction from the ZnO-NF phase prior to CV-AFS determination. Some essential parameters of the ZnO-NF VA-LLME and cold vapor generation such as composition and volume of the nanofluid, vortexing time, pH of the sample solution, amount of the chelating agent, ionic strength and matrix interferences have been studied. Under optimal conditions, efficient extraction of 1ng/mL of Hg(2+) in 10mL of sample solution was achieved using 50μL of ZnO-NF. The enrichment factor before dilution, detection limits and limits of quantification of the method were about 190, 0.019 and 0.064ng/mL, respectively. The intra and inter days relative standard deviations (n=8) were found to be 4.6% and 7.8%, respectively, at 1ng/mL spiking level. The accuracy of the current method was also evaluated by the analysis of certified reference materials, and the measured Hg(2+) concentration of GBW08603 (9.6ng/mL) and GBW(E)080392 (8.9ng/mL) agreed well with their certified value (10ng/mL). The method was applied to the analysis of Hg(2+) in effluent, influent, lake and river water samples, with recoveries in the range of 79.8-92.8% and 83.6-106.1% at 1ng/mL and 5ng/mL spiking levels, respectively. Overall, ZnO-NF VA-LLME is fast, simple, cost-effective and environmentally friendly and it can be employed for efficient enrichment of the analyte from various water samples.

  17. Guanidinium ionic liquid-based surfactants as low cytotoxic extractants: Analytical performance in an in-situ dispersive liquid-liquid microextraction method for determining personal care products.

    Science.gov (United States)

    Pacheco-Fernández, Idaira; Pino, Verónica; Ayala, Juan H; Afonso, Ana M

    2017-05-01

    The IL-based surfactant octylguanidinium chloride (C8Gu-Cl) was designed and synthetized with the purpose of obtaining a less harmful surfactant: containing guanidinium as core cation and a relatively short alkyl chain. Its interfacial and aggregation behavior was evaluated through conductivity and fluorescence measurements, presenting a critical micelle concentration value of 42.5 and 44.6mmolL(-1), respectively. Cytotoxicity studies were carried out with C8Gu-Cl and other IL-based and conventional surfactants, specifically the analogue 1-octyl-3-methylimidazolium chloride (C8MIm-Cl), and other imidazolium- (C16MIm-Br) and pyridinium- (C16Py-Cl) based surfactants, together with the conventional cationic CTAB and the conventional anionic SDS. From these studies, C8Gu-Cl was the only one to achieve the classification of low cytotoxicity. An in situ dispersive liquid-liquid microextraction (DLLME) method based on transforming the water-soluble C8Gu-Cl IL-based surfactant into a water-insoluble IL microdroplet via a simple metathesis reaction was then selected as the extraction/preconcentration method for a group of 6 personal care products (PCPs) present in cosmetic samples. The method was carried out in combination with high-performance liquid chromatography (HPLC) and diode array detection (DAD). The method was properly optimized, requiring the use of only 30μL of C8Gu-Cl for 10mL of aqueous sample with a NaCl content of 8% (w/v) to adjust the ionic strength and pH value of 5. The metathesis reaction required the addition of the anion exchange reagent (bis[(trifluoromethyl)sulfonyl]imide - 1:1 molar ratio), followed by vortex and centrifugation, and dilution of the final microdroplet up to 60μL with acetonitrile before the injection in the HPLC-DAD system. The optimum in situ DLLME-HPLC-DAD method takes ∼10min for the extraction step and ∼22min for the chromatographic separation, with analytical features of low detection limits: down to 0.4μgL(-1); high

  18. Arsenic speciation analysis in mono-varietal wines by on-line ionic liquid-based dispersive liquid-liquid microextraction.

    Science.gov (United States)

    Escudero, Leticia B; Martinis, Estefanía M; Olsina, Roberto A; Wuilloud, Rodolfo G

    2013-05-01

    A highly efficient separation and pre-concentration method for arsenic species determination, based on ionic liquid (IL) dispersive microextraction technique implemented in a flow analysis system, is proposed. Highly selective separation of arsenite species [As(III)] was achieved by chelation with sodium diethyldithiocarbamate (DDTC) followed by dispersion with 40 mg of 1-octyl-3-methylimidazolium hexafluorophosphate ([C(8)mim][PF(6)]) IL. Analyte extraction, retention and separation of IL phase were achieved with a packed microcolumn and As(III) was determined in eluent solution by electrothermal atomic absorption spectrometry (ETAAS). Concentration of As(V) was deduced by the difference between total inorganic arsenic and As(III). Thus, determination of total arsenic was performed by previous degradation of organo-arsenic species, followed by a reduction. Under optimal conditions, As(III) extraction efficiency was 100% and a sensitivity enhancement factor of 46 was obtained with only 4.0 ml of sample The method was successfully applied for arsenic speciation studies in mono-varietal wines.

  19. Vortex-assisted ionic liquid-based dispersive liquid-liquid microextraction for assessment of chromium species in artificial saliva extract of different chewing tobacco products.

    Science.gov (United States)

    Akhtar, Asma; Kazi, Tasneem Gul; Afridi, Hassan Imran; Musharraf, Syed Ghulam; Talpur, Farah Naz; Khan, Noman; Bilal, Muhammad; Khan, Mustafa

    2016-12-01

    A novel dispersive liquid-liquid microextraction (ILDLLμE) method using an extracting solvent (ionic liquid) and dispersant (Triton X-114) was developed for the separation and preconcentration of hexavalent chromium (Cr(6+)) in artificial saliva extract (ASE) of chewing tobacco products, gutkha, and mainpuri (n = 23). In the proposed method, the extraction of Cr(6+) was accomplished by using ammonium pyrrolidinedithiocarbamate (APDC) as complexing agent and 1-butyl-3-methylimidazolium hexafluorophosphate [C4MIM] [PF6] as extracting solvent. The tiny droplet of metal chelate was then dispersed into TX-114 emulsion, using vortex mixer. Various parameters such as concentration of APDC, pH of the solution, volume of [C4MIM] [PF6], and TX-114 as well as extraction time were studied. Under the most favorable conditions, the limit of detection was found to be 0.068 μg/L with the relative standard deviation carcinogenic and noncarcinogenic risks. Estimated daily intake of Cr via chewing 10 g/day of gutkha and mainpuri was found to be below the maximum tolerable daily intake, whereas the calculated risk of cancer for Cr was observed in the acceptable range of 10E(-6)-10E(-4), except some brands of gutkha. Graphical Abstract ᅟ.

  20. Application of ionic liquid-based dispersive liquid phase microextraction for highly sensitive simultaneous determination of three endocrine disrupting compounds in food packaging.

    Science.gov (United States)

    Wang, Lingling; Zhang, Danfeng; Xu, Xu; Zhang, Lei

    2016-04-15

    Ionic liquid (IL) dispersive liquid-liquid microextraction (DLLME) method was successfully developed for extracting three endocrine disrupting compounds (EDCs) (bisphenol A, bisphenol AF and bisphenol AP) from the food packaging. 1-Octyl-3-methylimidazoliumhexafluorophosphate ([C8MIM][PF6]) was selected as extraction solution. The extraction procedure did not require a dispersive solvent. Three EDCs extraction kinetics were found to be very fast and the equilibrium was attained within 3.0 min following the pseudo-first-order model. The H-bonding and hydrophobic interactions play an important role in the partitioning of EDCs into IL from aqueous solution. The recovered IL could be reused for three runs without significant loss of extraction efficiencies. The spiked recoveries of three targets in food packaging were in the range of 97.8-103.1%. The limits of detection ranged from 0.50 to 1.50 ng mL(-1) (S/N=3). As a result, this method has been successfully applied for the sensitive detection of three EDCs in real samples.

  1. Ionic liquid-based dispersive liquid-liquid microextraction with back-extraction coupled with capillary electrophoresis to determine phenolic compounds.

    Science.gov (United States)

    Zhou, Caihong; Tong, Shanshan; Chang, Yunxia; Jia, Qiong; Zhou, Weihong

    2012-04-01

    Ionic liquid (IL) based dispersive liquid-liquid microextraction (DLLME) with back-extraction coupled with capillary electrophoresis ultraviolet detection was developed to determine four phenolic compounds (bisphenol-A, β-naphthol, α-naphthol, 2, 4-dichlorophenol) in aqueous cosmetics. The developed method was used to preconcentrate and clean up the four phenolic compounds including two steps. The analytes were transferred into room temperature ionic liquid (1-octyl-3-methylimidazolium hexafluorophosphate, [C(8) MIM][PF(6) ]) rich-phase in the first step. In the second step, the analytes were back-extracted into the alkaline aqueous phase. The effects of extraction parameters, such as type and volume of extraction solvent, type and volume of disperser, extraction and centrifugal time, sample pH, salt addition, and concentration and volume of NaOH in back-extraction were investigated. Under the optimal experimental conditions, the preconcentration factors were 60.1 for bisphenol-A, 52.7 for β-naphthol, 49.2 for α-naphthol, and 18.0 for 2, 4-dichlorophenol. The limits of detection for bisphenol-A, β-naphthol, α-naphthol and 2, 4-dichlorophenol were 5, 5, 8, and 100 ng mL(-1), respectively. Four kinds of aqueous cosmetics including toner, soften lotion, make-up remover, and perfume were analyzed and yielded recoveries ranging from 81.6% to 119.4%. The main advantages of the proposed method are quick, easy, cheap, and effective.

  2. Enzyme-assisted extraction and ionic liquid-based dispersive liquid-liquid microextraction followed by high-performance liquid chromatography for determination of patulin in apple juice and method optimization using central composite design.

    Science.gov (United States)

    Mohammadi, Abdorreza; Tavakoli, Rouya; Kamankesh, Marzieh; Rashedi, Hamid; Attaran, Abdolmohammad; Delavar, Mostafa

    2013-12-01

    A simple and highly sensitive analytical methodology for isolation and determination of patulin in apple-juice samples, based on enzyme-assisted extraction (EAE) and ionic liquid-based dispersive liquid-liquid microextraction (IL-DLLME) was developed and optimized. Enzymes play essential roles in eliminating interference and increasing the extraction efficiency of patulin. Apple-juice samples were treated with pectinase and amylase. A mixture of 80 μL ionic liquid and 600 μL methanol (disperser solvent) was used for the IL-DLLME process. The sedimented phase was analyzed by high-performance liquid chromatography (HPLC). Experimental parameters controlling the performance of DLLME, were optimized using response surface methodology (RSM) based on central composite design (CCD). Under optimum conditions, the calibration curves showed high levels of linearity (R(2)>0.99) for patulin in the range of 1-200 ng g(-1). The relative standard deviation (RSD) for the seven analyses was 7.5%. The limits of detection (LOD) and limits of quantification (LOQ) were 0.15 ng g(-1) and 0.5 ng g(-1), respectively. The merit figures, compared with other methods, showed that new proposed method is an accurate, precise and reliable sample-pretreatment method that substantially reduces sample matrix interference and gives very good enrichment factors and detection limits for investigation trace amount of patulin in apple-juice samples.

  3. Temperature-controlled ionic liquid-based ultrasound-assisted microextraction for preconcentration of trace quantity of cadmium and nickel by using organic ligand in artificial saliva extract of smokeless tobacco products

    Science.gov (United States)

    Arain, Sadaf Sadia; Kazi, Tasneem Gul; Arain, Asma Jabeen; Afridi, Hassan Imran; Baig, Jameel Ahmed; Brahman, Kapil Dev; Naeemullah; Arain, Salma Aslam

    2015-03-01

    A new approach was developed for the preconcentration of cadmium (Cd) and nickel (Ni) in artificial saliva extract of dry snuff (brown and black) products using temperature-controlled ionic liquid-based ultrasound-assisted dispersive liquid-liquid microextraction (TIL-UDLLμE) followed by electrothermal atomic absorption spectrometry (ETAAS). The Cd and Ni were complexed with ammonium pyrrolidinedithiocarbamate (APDC), extracted in ionic liquid drops, 1-butyl-3-methylimidazolium hexafluorophosphate [C4MIM][PF6]. The multivariate strategy was applied to estimate the optimum values of experimental variables influence the % recovery of analytes by TIL-UDLLμE method. At optimum experimental conditions, the limit of detection (3s) were 0.05 and 0.14 μg L-1 while relative standard deviations (% RSD) were 3.97 and 3.55 for Cd and Ni respectively. After extraction, the enhancement factors (EF) were 87 and 79 for Cd and Ni, respectively. The RSD for six replicates of 10 μg L-1 Cd and Ni were 3.97% and 3.55% respectively. To validate the proposed method, certified reference material (CRM) of Virginia tobacco leaves was analyzed, and the determined values of Cd and Ni were in good agreement with the certified values. The concentration of Cd and Ni in artificial saliva extracts corresponds to 39-52% and 21-32%, respectively, of the total contents of both elements in dry brown and black snuff products.

  4. Ionic liquid based dispersive liquid-liquid microextraction coupled with micro-solid phase extraction of antidepressant drugs from environmental water samples.

    Science.gov (United States)

    Ge, Dandan; Lee, Hian Kee

    2013-11-22

    Ionic liquid-dispersive liquid-liquid microextraction combined with micro-solid phase extraction (IL-DLLME-μ-SPE), and high-performance liquid chromatography (HPLC) was developed for the determination of tricyclic antidepressants (TCAs) in water samples. Two hundred microliters of an organic solvent (as disperser solvent) and 20 μl of 1-hexyl-3-methylimidazolium tris(pentafluoroethyl)trifluorophosphate were injected into a 5.0 ml sample for sonication-assisted DLLME. After this, a μ-SPE device, containing a novel material zeolite imidazolate framework 4 (ZIF-4), was added into the sample solution and 1 min of vortex-assisted extraction was performed. After 5 min of sonication-assisted desorption, 10 μl of desorption solvent was injected into a HPLC system for analysis. A characteristic property of DLLME-VA-μ-SPE is that any organic solvent and solid sorbent immiscible with water can be used. Special apparatus, or conical-bottom test tubes, and tedious procedures conventionally associated with DLLME such as centrifugation, or refrigeration of solvent are not necessary in the present approach. A novel material, ZIF-4 was employed as μ-SPE sorbent. Under the optimized conditions, the calibration curves were linear in the range of 1-1000 μg/L. The relative standard deviations and the limits of detection were in the range of 1.5% and 7.8% and 0.3 and 1 μg/L, respectively. The relative recoveries of canal water samples, spiked with drugs, were in the range of 94.3% and 114.7%. The results showed that IL-DLLME-μ-SPE was suitable for the determination of TCAs in water samples.

  5. Temperature controlled ionic liquid-based dispersive micro-extraction using two ligands, for determination of aluminium in scalp hair samples of Alzheimer's patients: A multivariate study

    Science.gov (United States)

    Arain, Mariam S.; Arain, Salma A.; Kazi, Tasneem G.; Afridi, Hassan I.; Ali, Jamshaid; Naeemulllah; Arain, Sadaf S.; Brahman, Kapil Dev; Mughal, Moina Akhtar

    2015-02-01

    A green and sensitive temperature controlled dispersive liquid-liquid microextraction (TIL-DLLME) methodology based on the application of ionic liquid 1-butyl-3-methylimidazolium hexafluorophosphate, [C4mim][PF6], as an extractant solvent was proposed for the preconcentration of trace levels of aluminium (Al3+) in scalp hair samples of Alzheimer's (AD) patients, prior to analyzing by flame atomic absorption spectrometry (FAAS). The Al3+ was complexed with 8-hydrooxyquinoline (oxine) (L1) and 3,5,7,2‧-4‧ pentahydroxy flavone (morin) (L2) separately and then extracted by IL at temperature (50 ± 2.0 °C). Some effective factors that influence the TIL-DLLME efficiency such as pH, ligands concentrations, volume of IL, ionic strength, and incubation time were investigated and optimized by multivariate analysis. In the optimum experimental conditions, the limit of detection (3 s) and enhancement factor were 0.56 μg L-1, 0.64 μg L-1 and 85, 73 for both ligands, respectively. The relative standard deviation (RSD) for six replicate determinations of 100 μg L-1 Al3+ complexed with oxine and morin were found to be 3.88% and 4.74%, respectively. The developed method was validated by the analysis of certified reference material of human hair (NCSZC81002).and applied satisfactorily to the determination of Al3+ in acid digested scalp hair samples of AD patients and healthy controls. The resulted data shows significant higher level in scalp hair samples of AD male patients with related to referents of same age and socioeconomic status.

  6. Temperature controlled ionic liquid-based dispersive micro-extraction using two ligands, for determination of aluminium in scalp hair samples of Alzheimer's patients: a multivariate study.

    Science.gov (United States)

    Arain, Mariam S; Arain, Salma A; Kazi, Tasneem G; Afridi, Hassan I; Ali, Jamshaid; Naeemulllah; Arain, Sadaf S; Brahman, Kapil Dev; Mughal, Moina Akhtar

    2015-02-25

    A green and sensitive temperature controlled dispersive liquid-liquid microextraction (TIL-DLLME) methodology based on the application of ionic liquid 1-butyl-3-methylimidazolium hexafluorophosphate, [C4mim][PF6], as an extractant solvent was proposed for the preconcentration of trace levels of aluminium (Al(3+)) in scalp hair samples of Alzheimer's (AD) patients, prior to analyzing by flame atomic absorption spectrometry (FAAS). The Al(3+) was complexed with 8-hydrooxyquinoline (oxine) (L1) and 3,5,7,2'-4' pentahydroxy flavone (morin) (L2) separately and then extracted by IL at temperature (50±2.0°C). Some effective factors that influence the TIL-DLLME efficiency such as pH, ligands concentrations, volume of IL, ionic strength, and incubation time were investigated and optimized by multivariate analysis. In the optimum experimental conditions, the limit of detection (3s) and enhancement factor were 0.56 μg L(-1), 0.64 μg L(-1) and 85, 73 for both ligands, respectively. The relative standard deviation (RSD) for six replicate determinations of 100 μg L(-1) Al(3+) complexed with oxine and morin were found to be 3.88% and 4.74%, respectively. The developed method was validated by the analysis of certified reference material of human hair (NCSZC81002).and applied satisfactorily to the determination of Al(3+) in acid digested scalp hair samples of AD patients and healthy controls. The resulted data shows significant higher level in scalp hair samples of AD male patients with related to referents of same age and socioeconomic status.

  7. Separation of curcuminoids using ionic liquid based aqueous two-phase system coupled with in situ dispersive liquid-liquid microextraction.

    Science.gov (United States)

    Shu, Yang; Gao, Mingcen; Wang, Xueying; Song, Rusheng; Lu, Jun; Chen, Xuwei

    2016-01-01

    An aqueous two-phase extraction system (ATPS) combined with an in situ dispersive liquid-liquid microextraction (DLLME) method using imidazolium ionic liquids (ILs) for the separation of curcuminoids is developed. The influence of structure of IL, the type of metathesis reagents, and the back extraction agents on the extraction efficiency is investigated. 2.0mg of curcuminoids are extracted by an IL ATPS composed of 0.4g 1,3-diethylimidazolium iodine (EeimI), 0.6g potassium hydrogen phosphate, 1.0g water. Then the bis[(trifluoromethyl)sulfonyl]imide lithium (LiNTf2) aqueous solution is added to the EeimI-rich phase of the ATPS. The water-immiscible ionic liquids, 1,3-diethylimidazole bis[(trifluoromethyl)sulfonyl]imide (EeimNTf2), forms by the metathesis reaction. The in situ DLLME is triggered simultaneously and further purifies the curcuminoids. 92% of EeimI transforms into EeimNTf2 and thus the Eeim(+) cation is used for twice in this method. Finally, 0.1mol/L NaOH aqueous solution is used as the back extraction reagent. The curcuminoids precipitate is achieved with 93% of recovery when the aqueous solution is adjusted to pH 3.0. This ATPS-DLLME method is successfully applied to the separation of curcuminoids from Curcuma Longa (0.96±0.02% of extraction yield, a purity of >51% with respect to the total dry mass of the product).

  8. A new dispersive liquid-liquid microextraction using ionic liquid based microemulsion coupled with cloud point extraction for determination of copper in serum and water samples.

    Science.gov (United States)

    Arain, Salma Aslam; Kazi, Tasneem Gul; Afridi, Hassan Imran; Arain, Mariam Shahzadi; Panhwar, Abdul Haleem; Khan, Naeemullah; Baig, Jameel Ahmed; Shah, Faheem

    2016-04-01

    A simple and rapid dispersive liquid-liquid microextraction procedure based on ionic liquid assisted microemulsion (IL-µE-DLLME) combined with cloud point extraction has been developed for preconcentration copper (Cu(2+)) in drinking water and serum samples of adolescent female hepatitits C (HCV) patients. In this method a ternary system was developed to form microemulsion (µE) by phase inversion method (PIM), using ionic liquid, 1-butyl-3-methylimidazolium hexafluorophosphate ([C4mim][PF6]) and nonionic surfactant, TX-100 (as a stabilizer in aqueous media). The Ionic liquid microemulsion (IL-µE) was evaluated through visual assessment, optical light microscope and spectrophotometrically. The Cu(2+) in real water and aqueous acid digested serum samples were complexed with 8-hydroxyquinoline (oxine) and extracted into IL-µE medium. The phase separation of stable IL-µE was carried out by the micellar cloud point extraction approach. The influence of of different parameters such as pH, oxine concentration, centrifugation time and rate were investigated. At optimized experimental conditions, the limit of detection and enhancement factor were found to be 0.132 µg/L and 70 respectively, with relative standard deviation <5%. In order to validate the developed method, certified reference materials (SLRS-4 Riverine water) and human serum (Sero-M10181) were analyzed. The resulting data indicated a non-significant difference in obtained and certified values of Cu(2+). The developed procedure was successfully applied for the preconcentration and determination of trace levels of Cu(2+) in environmental and biological samples.

  9. Hybrid flow analyzer for automatic hollow-fiber-assisted ionic liquid-based liquid-phase microextraction with in-line membrane regeneration.

    Science.gov (United States)

    Nitiyanontakit, Sira; Varanusupakul, Pakorn; Miró, Manuel

    2013-04-01

    The proof-of-concept of a new methodology for in-line hollow-fiber (HF)-assisted three-phase liquid-phase microextraction (LPME) allowing for handling of the feed and acceptor aqueous solutions and of minute volumes of the organic extracting phase in a programmable flow mode is reported in this paper. The flow analyzer fosters in-line anchoring of ionic-liquid-laden extracting solution (10 % (v/v) methyltrioctyl ammonium chloride in kerosene) in the pores of a single-strand microporous polypropylene HF, and regeneration of the liquid-phase membrane itself for each individual analysis cycle in a fully automated mode. Using hexavalent chromium as a model analyte and 1,5-diphenylcarbazide as a chromogenic probe in the acceptor solution, the flow-based HF-LPME hyphenated system was harnessed to the clean-up of troublesome samples (viz., domestic wastewater and soil leachates) with concomitant enrichment of target species. Distinct extraction modes and chemistries were assessed for enhanced Cr(VI) permeability. A single sample plug was subjected to a twofold backward-forward flow extraction so as to decrease the thickness of the boundary layer at the HF shell side for improved extraction efficiency. Under the optimized physicochemical variables, a limit of detection of 4.6 μg L(-1) Cr(VI), a dynamic linear range of up to 500 μg L(-1) and intermediate precision better than 10 % were obtained for a sample volume of 2.8 mL buffered at pH 4 and a volume of organic extractant of 120 μL, with an enrichment factor of ca. 11 for a sample residence time in the donor compartment of merely 4.5 min. Analyte recoveries in domestic wastewaters were ≥83 % using external calibration with relative standard deviations better than 14 %, thereby demonstrating the expedient clean-up of samples with elevated content of dissolved organic carbon. The automatic HF-LPME method was validated in terms of bias against the SRM 2701 (NIST soil) preceded by the EPA alkaline digestion method 3060A

  10. Ionic liquid-based dispersive liquid-liquid microextraction combined with high performance liquid chromatography-UV detection for simultaneous preconcentration and determination of Ni, Co, Cu and Zn in water samples

    Directory of Open Access Journals (Sweden)

    Asghari Alireza

    2014-01-01

    Full Text Available Ionic liquid-based dispersive liquid-liquid microextraction (IL-DLLME coupled with high performance liquid chromatography (HPLC-UV detection was developed for simultaneous extraction and determination of nickel, cobalt, copper and zinc ions. In the proposed approach, salophen (N,N'-bis(salisyliden-1,2-phenylenediamine was used as a chelating agent; the ionic liquid, 1-hexeyl-3-methylimidazolium hexafluorophosphate, and acetone were selected as extracting and dispersive solvents, respectively. After extraction, phase separation was performed by centrifugation and the sedimented phase (ionic liquid was solubilized in acetonitrile and directly injected into the HPLC for subsequent analysis. Baseline separation of metal ion complexes was achieved on a RP-C18 column using a gradient elution of the mixtures of methanol-acetonitrile-water as the mobile phase at a flow rate of 1.0 mL min-1. The influence of variables such as sample pH, concentration of the chelating agent, amount of ionic liquid (extraction solvent, disperser solvent volume, extraction time, salt effect and centrifugation speed were studied and optimized. Under the optimum conditions, the enrichment factor of 222 was obtained. The detection limits for Ni, Co, Cu and Zn were 0.8, 1.6, 1.9 and 2.8 μg L−1, respectively. The relative standard deviations (RSDs were in the range of 3.6-5.0 % for all of the investigated metal ions. The proposed procedure was successfully applied to the determination of the studied metal ions in water samples.

  11. Microwave-assisted headspace single-drop microextration of chlorobenzenes from water samples.

    Science.gov (United States)

    Vidal, Lorena; Domini, Claudia E; Grané, Nuria; Psillakis, Elefteria; Canals, Antonio

    2007-05-29

    A one-step and in-situ sample preparation method used for quantifying chlorobenzene compounds in water samples has been developed, coupling microwave and headspace single-drop microextraction (MW-HS-SDME). The chlorobenzenes in water samples were extracted directly onto an ionic liquid single-drop in headspace mode under the aid of microwave radiation. For optimization, a Plackett-Burman screening design was initially used, followed by a mixed-level factorial design. The factors considered were: drop volume, aqueous sample volume, stirring speed, ionic strength, extraction time, ionic liquid type, microwave power and length of the Y-shaped glass-tube. The optimum experimental conditions found from this statistical evaluation were: a 5 microL microdrop of 1-hexyl-3-methylimidazolium hexafluorophosphate exposed for 20 min to the headspace of a 30 mL aqueous sample, irradiated by microwaves at 200 W and placed in a 50 mL spherical flask connected to a 25 cm Y-shaped glass-tube. Under the optimised experimental conditions, the response of a high performance liquid chromatographic system was found to be linear over the range studied and with correlation coefficients ranging between 0.9995 and 0.9999. The method showed a good level of repeatability, with relative standard deviations varying between 2.3 and 8.3% (n=5). Detection limits were found in the low microg L(-1) range varying between 0.016 and 0.039 microg L(-1). Overall, the performance of the proposed method demonstrated the favourable effect of microwave sample irradiation upon HS-SDME. Finally, recovery studies from different types of environmental water samples revealed that matrix had little effect upon extraction.

  12. Microwave-assisted headspace single-drop microextration of chlorobenzenes from water samples

    Energy Technology Data Exchange (ETDEWEB)

    Vidal, Lorena [Departamento de Quimica Analitica, Nutricion y Bromatologia, Universidad de Alicante, P.O. Box 99, E-03080 Alicante (Spain); Domini, Claudia E. [Departamento de Quimica Analitica, Nutricion y Bromatologia, Universidad de Alicante, P.O. Box 99, E-03080 Alicante (Spain); Grane, Nuria [Departamento de Quimica Analitica, Nutricion y Bromatologia, Universidad de Alicante, P.O. Box 99, E-03080 Alicante (Spain); Psillakis, Elefteria [Department of Environmental Engineering, Technical University of Crete, Polytechneioupolis, GR-73100 Chania, Crete (Greece); Canals, Antonio [Departamento de Quimica Analitica, Nutricion y Bromatologia, Universidad de Alicante, P.O. Box 99, E-03080 Alicante (Spain)]. E-mail: a.canals@ua.es

    2007-05-29

    A one-step and in-situ sample preparation method used for quantifying chlorobenzene compounds in water samples has been developed, coupling microwave and headspace single-drop microextraction (MW-HS-SDME). The chlorobenzenes in water samples were extracted directly onto an ionic liquid single-drop in headspace mode under the aid of microwave radiation. For optimization, a Plackett-Burman screening design was initially used, followed by a mixed-level factorial design. The factors considered were: drop volume, aqueous sample volume, stirring speed, ionic strength, extraction time, ionic liquid type, microwave power and length of the Y-shaped glass-tube. The optimum experimental conditions found from this statistical evaluation were: a 5 {mu}L microdrop of 1-hexyl-3-methylimidazolium hexafluorophosphate exposed for 20 min to the headspace of a 30 mL aqueous sample, irradiated by microwaves at 200 W and placed in a 50 mL spherical flask connected to a 25 cm Y-shaped glass-tube. Under the optimised experimental conditions, the response of a high performance liquid chromatographic system was found to be linear over the range studied and with correlation coefficients ranging between 0.9995 and 0.9999. The method showed a good level of repeatability, with relative standard deviations varying between 2.3 and 8.3% (n = 5). Detection limits were found in the low {mu}g L{sup -1} range varying between 0.016 and 0.039 {mu}g L{sup -1}. Overall, the performance of the proposed method demonstrated the favourable effect of microwave sample irradiation upon HS-SDME. Finally, recovery studies from different types of environmental water samples revealed that matrix had little effect upon extraction.

  13. Methods of liquid phase microextraction for the determination of cadmium in environmental samples.

    Science.gov (United States)

    Pires Santos, Analú; das Graças Andrade Korn, Maria; Azevedo Lemos, Valfredo

    2017-08-09

    Liquid phase microextraction (LPME) has been widely used in extraction and preconcentration systems as an excellent alternative to conventional liquid phase extraction. In this work, a critical review is presented on liquid phase microextraction techniques used in the determination of cadmium in environmental samples. LPME techniques are classified into three main groups: single-drop liquid phase microextraction (SDME), hollow fiber liquid phase microextraction (HF-LPME), and dispersive liquid-liquid microextraction (DLLME). Methods involving these liquid phase microextraction techniques are described, addressing advantages and disadvantages, samples, figures of merit, and trends.

  14. Application of ionic liquid in liquid phase microextraction technology.

    Science.gov (United States)

    Han, Dandan; Tang, Baokun; Lee, Yu Ri; Row, Kyung Ho

    2012-11-01

    Ionic liquids (ILs) are novel nonmolecular solvents. Their unique properties, such as high thermal stability, tunable viscosity, negligible vapor pressure, nonflammability, and good solubility for inorganic and organic compounds, make them excellent candidates as extraction media for a range of microextraction techniques. Many physical properties of ILs can be varied, and the structural design can be tuned to impart the desired functionality and enhance the analyte extraction selectivity, efficiency, and sensitivity. This paper provides an overview of the applications of ILs in liquid phase microextraction technology, such as single-drop microextraction, hollow fiber based liquid phase microextraction, and dispersive liquid-liquid microextraction. The sensitivity, linear calibration range, and detection limits for a range of target analytes in the methods were analyzed to determine the advantages of ILs in liquid phase microextraction. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Rapid and sensitive analysis of polychlorinated biphenyls and acrylamide in food samples using ionic liquid-based in situ dispersive liquid-liquid microextraction coupled to headspace gas chromatography.

    Science.gov (United States)

    Zhang, Cheng; Cagliero, Cecilia; Pierson, Stephen A; Anderson, Jared L

    2017-01-20

    A simple and rapid ionic liquid (IL)-based in situ dispersive liquid-liquid microextraction (DLLME) method was developed and coupled to headspace gas chromatography (HS-GC) employing electron capture (ECD) and mass spectrometry (MS) detection for the analysis of polychlorinated biphenyls (PCBs) and acrylamide at trace levels from milk and coffee samples. The chemical structures of the halide-based ILs were tailored by introducing various functional groups to the cations to evaluate the effect of different structural features on the extraction efficiency of the target analytes. Extraction parameters including the molar ratio of IL to metathesis reagent and IL mass were optimized. The effects of HS oven temperature and the HS sample vial volume on the analyte response were also evaluated. The optimized in situ DLLME method exhibited good analytical precision, good linearity, and provided detection limits down to the low ppt level for PCBs and the low ppb level for acrylamide in aqueous samples. The matrix-compatibility of the developed method was also established by quantifying acrylamide in brewed coffee samples. This method is much simpler and faster compared to previously reported GC-MS methods using solid-phase microextraction (SPME) for the extraction/preconcentration of PCBs and acrylamide from complex food samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Determination of acrylamide in brewed coffee and coffee powder using polymeric ionic liquid-based sorbent coatings in solid-phase microextraction coupled to gas chromatography-mass spectrometry.

    Science.gov (United States)

    Cagliero, Cecilia; Ho, Tien D; Zhang, Cheng; Bicchi, Carlo; Anderson, Jared L

    2016-06-03

    This study describes a simple and rapid sampling method employing a polymeric ionic liquid (PIL) sorbent coating in direct immersion solid-phase microextraction (SPME) for the trace-level analysis of acrylamide in brewed coffee and coffee powder. The crosslinked PIL sorbent coating demonstrated superior sensitivity in the extraction of acrylamide compared to all commercially available SPME coatings. A spin coating method was developed to evenly distribute the PIL coating on the SPME support and reproducibly produce fibers with a large film thickness. Ninhydrin was employed as a quenching reagent during extraction to inhibit the production of interfering acrylamide. The PIL fiber produced a limit of quantitation for acrylamide of 10μgL(-1) and achieved comparable results to the ISO method in the analysis of six coffee powder samples.

  17. Sensitive determination of trace urinary 3-hydroxybenzo[a]pyrene using ionic liquids-based dispersive liquid-liquid microextraction followed by chemical derivatization and high performance liquid chromatography-high resolution tandem mass spectrometry.

    Science.gov (United States)

    Hu, Huan; Liu, Baizhan; Yang, Jun; Lin, Zuomin; Gan, Wuer

    2016-08-01

    3-Hydroxybenzo[a]pyrene (3-OHBaP) is widely used as a biomarker for assessing carcinogenic benzo[a]pyrene exposure risks. However, monitoring urinary 3-OHBaP suffers from an insufficient sensitivity due to the pg/mL level in urine excretion. In this study, a sensitive method for determination trace urinary 3-OHBaP was developed, involving enzymatic hydrolysis of the glucuronide and sulfate conjugates, ionic liquids dispersive liquid-liquid microextraction (IL-DLLME) enrichment, derivatization with dansyl chloride and HPLC-HRMS/MS analysis in the positive ion mode. Using IL-DLLME makes the enrichment of trace 3-OHBaP very simple, time-saving, efficiency and environmentally-friendly. To enhanced HPLC-HRMS/MS response, an MS-friendly dansyl group was introduced to increase the ionization and fragmentation efficiency. The optimal IL-DLLME extraction parameters and derivatization reaction conditions were investigated. Good linearity was obtained over a concentration range of 0.6-50.0pg/mL with correlation coefficients (r(2)) of 0.9918. The limit of detection (LOD) and limit of quantification (LOQ) values were 0.2pg/mL and 0.58pg/mL, respectively. The recoveries were 92.0±4.2% with the intra-day and inter-day RSD values ranged from 2.2% to 3.8% and from 3.3% to 6.8%, respectively. The proposed IL-DLLME-Dansylation-HPLC-HRMS/MS method was successfully applied to determine urinary 3-OHBaP of non-occupational exposed smokers and nonsmokers.

  18. Utilization of highly robust and selective crosslinked polymeric ionic liquid-based sorbent coatings in direct-immersion solid-phase microextraction and high-performance liquid chromatography for determining polar organic pollutants in waters.

    Science.gov (United States)

    Pacheco-Fernández, Idaira; Najafi, Ali; Pino, Verónica; Anderson, Jared L; Ayala, Juan H; Afonso, Ana M

    2016-09-01

    Several crosslinked polymeric ionic liquid (PIL)-based sorbent coatings of different nature were prepared by UV polymerization onto nitinol wires. They were evaluated in a direct-immersion solid-phase microextraction (DI-SPME) method in combination with high-performance liquid chromatography (HPLC) and diode array detection (DAD). The studied PIL coatings contained either vinyl alkyl or vinylbenzyl imidazolium-based (ViCnIm- or ViBCnIm-) IL monomers with different anions, as well as different dicationic IL crosslinkers. The analytical performance of these PIL-based SPME coatings was firstly evaluated for the extraction of a group of 10 different model analytes, including hydrocarbons and phenols, while exhaustively comparing the performance with commercial SPME fibers such as polydimethylsyloxane (PDMS), polyacrylate (PA) and polydimethylsiloxane/divinylbenzene (PDMS/DVB), and using all fibers under optimized conditions. Those fibers exhibiting a high selectivity for polar compounds were selected to carry out an analytical method for a group of 5 alkylphenols, including bisphenol-A (BPA) and nonylphenol (n-NP). Under optimum conditions, average relative recoveries of 108% and inter-day precision values (3 non-consecutive days) lower than 19% were obtained for a spiked level of 10µgL(-1). Correlations coefficients for the overall method ranged between 0.990 and 0.999, and limits of detection were down to 1µgL(-1). Tap water, river water, and bottled water were analyzed to evaluate matrix effects. Comparison with the PA fiber was also performed in terms of analytical performance. Partition coefficients (logKfs) of the alkylphenols to the SPME coating varied from 1.69 to 2.45 for the most efficient PIL-based fiber, and from 1.58 to 2.30 for the PA fiber. These results agree with those obtained by the normalized calibration slopes, pointing out the affinity of these PILs-based coatings.

  19. Development and validation of a fast ionic liquid-based dispersive liquid-liquid microextraction procedure combined with LC-MS/MS analysis for the quantification of benzodiazepines and benzodiazepine-like hypnotics in whole blood.

    Science.gov (United States)

    De Boeck, Marieke; Missotten, Sophie; Dehaen, Wim; Tytgat, Jan; Cuypers, Eva

    2016-12-26

    To date, thorough clean-up of complex biological samples remains an essential part of the analytical process. The solid phase extraction (SPE) technique is the well-known standard, however, its main weaknesses are the labor-intensive and time-consuming protocols. In this respect, dispersive liquid-liquid microextractions (DLLME) seem to offer less complex and more efficient extraction procedures. Furthermore, ionic liquids (ILs) - liquid salts - are emerging as new promising extraction solvents, thanks to their non-flammable nature, negligible vapor pressure and easily adaptable physiochemical properties. In this study, we investigated whether ILs can be used as an extraction solvent in a DLLME procedure for the extraction of a broad range of benzodiazepines and benzodiazepine-like hypnotics in whole blood samples. 1.0mL whole blood was extracted using an optimized 30-min IL-based DLLME procedure, followed by LC-ESI(+)-MS/MS analysis in scheduled MRM scan mode. The optimized analytical method was successfully validated for 7-aminoflunitrazepam, alprazolam, bromazepam, clobazam, clonazepam, clotiazepam, diazepam, estazolam, ethyl loflazepate, etizolam, flurazepam, lormetazepam, midazolam, oxazepam, prazepam, temazepam, triazolam, zolpidem and zopiclone. The method showed good selectivity for endogenous interferences based on 12 sources of blank whole blood. No benzodiazepine interferences were observed, except for clorazepate and nordiazepam, which were excluded from the quantitative method. Matrix-matched calibration curves were constructed covering the whole therapeutic range, including low toxic plasma concentrations. Accuracy and precision results met the proposed acceptance criteria for the vast majority of compounds, except for brotizolam, chlordiazepoxide, cloxazolam, flunitrazepam, loprazolam, lorazepam and nitrazepam, which can only be determined in a semi-quantitative way. Recoveries were within the range of 24.7%-127.2% and matrix effects were within 20

  20. The effect of cooling rate on undercooling of pure Sn single drop

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Bin; Zhuravlev, Evgeny; Schmelzer, Juern; Schick, Christoph [Institute of Physics, University of Rostock (Germany); Gao, Yulai [Shanghai Key Laboratory of Modern Metallurgy and MaterialsProcessing, Shanghai University (China); Abyzov, Alexander S. [National Science Center, Kharkov Institute of Physics and Technology (Ukraine)

    2011-07-01

    The cooling rate dependence of undercooling of pure Sn single drop is studied by the non-adiabatic fast scanning calorimetry in a large range of cooling rate spanning four orders of magnitude. The experimental results and theoretical analysis show that the undercooling can be obviously increased first with increasing cooling rate going over to a stage of slow increase for high cooling rates, which indicates a shelf-like dependence of undercooling on cooling rate before and after a ''crossover'' at higher cooling rate where two different heterogeneous mechanisms act simultaneously.

  1. Green aspects, developments and perspectives of liquid phase microextraction techniques.

    Science.gov (United States)

    Spietelun, Agata; Marcinkowski, Łukasz; de la Guardia, Miguel; Namieśnik, Jacek

    2014-02-01

    Determination of analytes at trace levels in complex samples (e.g. biological or contaminated water or soils) are often required for the environmental assessment and monitoring as well as for scientific research in the field of environmental pollution. A limited number of analytical techniques are sensitive enough for the direct determination of trace components in samples and, because of that, a preliminary step of the analyte isolation/enrichment prior to analysis is required in many cases. In this work the newest trends and innovations in liquid phase microextraction, like: single-drop microextraction (SDME), hollow fiber liquid-phase microextraction (HF-LPME), and dispersive liquid-liquid microextraction (DLLME) have been discussed, including their critical evaluation and possible application in analytical practice. The described modifications of extraction techniques deal with system miniaturization and/or automation, the use of ultrasound and physical agitation, and electrochemical methods. Particular attention was given to pro-ecological aspects therefore the possible use of novel, non-toxic extracting agents, inter alia, ionic liquids, coacervates, surfactant solutions and reverse micelles in the liquid phase microextraction techniques has been evaluated in depth. Also, new methodological solutions and the related instruments and devices for the efficient liquid phase micoextraction of analytes, which have found application at the stage of procedure prior to chromatographic determination, are presented.

  2. Mass transfer intensification of nanofluid single drops with effect of temperature

    Energy Technology Data Exchange (ETDEWEB)

    Saien, Javad; Zardoshti, Mahdi [Bu-Ali Sina University, Hamedan (Iran, Islamic Republic of)

    2015-11-15

    The hydrodynamics and mass transfer of organic nanofluid single drops in liquid-liquid extraction process were investigated within temperature range of 20 to 40 .deg. C. Nanofluid drops of toluene+acetic acid, containing surface modified magnetite nanoparticles (NPs) with concentration within the range of (0.0005-0.005) wt%, were conducted in aqueous continuous phase. The rate of solute mass transfer was generally enhanced with NPs until about 0.002wt%, and small drops benefited more. The enhancement reached 184.1% with 0.002 wt% of NPs at 40 .deg. C; however, adding more NPs led to the mass transfer to either remain constant or face a reduction, depending on the applied temperature. The mass transfer coefficient was nicely reproduced using a developed correlation for enhancement factor of molecular diffusivity as a function of Reynolds and Schmidt numbers.

  3. Terminal Effect of Drop Coalescence on Single Drop Mass Transfer Measurements and Its Minimization

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    For the mass transfer to single drops during the stage of steady buoyancy-driven motion, experimental measurement is complicated with the terminal effect of additional mass transfer during drop formation and coa lescence at the drop collector. Analysis reveals that consistent operating conditions and experimental procedure are of critical significance for minimizing the terminal effect of drop coalescence on the accuracy of mass transfer measurements. The novel design of a totally-closed extraction column is proposed for this purpose, which guaran tees that the volumetric rate of drop phase injection is exactly equal to that of withdrawal of drops. Tests in two extraction systems demonstrate that the experimental repeatability is improved greatly and the terminal effect of mass transfer during drop coalescence is brought well under control.

  4. Liquid phase microextraction for the analysis of trace elements and their speciation

    Science.gov (United States)

    Hu, Bin; He, Man; Chen, Beibei; Xia, Linbo

    2013-08-01

    Trace/ultra-trace elements and their speciation analysis in complex matrices usually require sample preparation procedures to achieve sample clean-up and analyte preconcentration. Sample preparation is often the bottleneck in trace elements and their speciation analysis which has a direct impact on accuracy, precision and limits of detection and is often the rate-determining step of the analytical process. Recent trends in sample preparation include miniaturization, automation, high-throughput performance and reduction in solvent/sample consumption and operation time. Liquid-phase microextraction (LPME) technique as a novel and promising alternative in sample preparation can meet these requirements and has become a very efficient sample preparation technique. This review updates the state of art of LPME for trace elements and their speciation analysis and discusses its promising prospects. The major thrust of the article highlights the applications of LPME including single-drop microextraction (SDME), hollow fiber-liquid phase microextraction (HF-LPME), dispersive liquid liquid microextraction (DLLME) and solidified floating organic drop microextraction (SFODME) to the fields of elemental and their speciation analysis by atomic spectrometry-based methods, especially inductively coupled plasma mass spectrometry. General and specific concepts, different extraction formats and characteristics of LPME are described and compared, along with examples of recent innovations and applications presented to demonstrate its potential for trace elements and their speciation analysis in biological and environmental fields. Moreover, the application potential and an outlook on the combination of LPME and atomic spectrometry-based techniques for inorganic analysis are commentated.

  5. Applications of Liquid-Phase Microextraction in the Sample Preparation of Environmental Solid Samples

    Directory of Open Access Journals (Sweden)

    Helena Prosen

    2014-05-01

    Full Text Available Solvent extraction remains one of the fundamental sample preparation techniques in the analysis of environmental solid samples, but organic solvents are toxic and environmentally harmful, therefore one of the possible greening directions is its miniaturization. The present review covers the relevant research from the field of application of microextraction to the sample preparation of environmental solid samples (soil, sediments, sewage sludge, dust etc. published in the last decade. Several innovative liquid-phase microextraction (LPME techniques that have emerged recently have also been applied as an aid in sample preparation of these samples: single-drop microextraction (SDME, hollow fiber-liquid phase microextraction (HF-LPME, dispersive liquid-liquid microextraction (DLLME. Besides the common organic solvents, surfactants and ionic liquids are also used. However, these techniques have to be combined with another technique to release the analytes from the solid sample into an aqueous solution. In the present review, the published methods were categorized into three groups: LPME in combination with a conventional solvent extraction; LPME in combination with an environmentally friendly extraction; LPME without previous extraction. The applicability of these approaches to the sample preparation for the determination of pollutants in solid environmental samples is discussed, with emphasis on their strengths, weak points and environmental impact.

  6. 离子液体均相液液微萃取-高效液相色谱法测定婴儿奶粉中5种三嗪类除草剂%Determination of five triazine herbicides in infant milk powder by high performance liquid chromatography coupled with ionic liquid-based homogeneous liquid-liquid microextraction

    Institute of Scientific and Technical Information of China (English)

    张丽媛; 姚笛; 李娜; 张寒琦; 于爱民

    2015-01-01

    建立了婴儿配方奶粉中三嗪类除草剂的均相液液微萃取-高效液相色谱分析方法。以离子液体为液液微萃取溶剂,Eclipse XDB-C18为色谱柱,乙腈和水为流动相梯度洗脱分离。详细研究了液液微萃取条件对实验结果的影响。在最优实验条件下,三嗪类除草剂的标准曲线呈良好的线性( r≥0.9992),草净津、敌草净、特丁通、特丁津和异戊乙净的检出限分别是12.1、13.8、11.8、14.6和13.7μg/kg;婴儿配方奶粉中的加标回收率为92.2%~103.2%,相对标准偏差低于6%。该方法灵敏度高、操作简单,适用于奶粉样品中三嗪类除草剂残留的检测。%A high performance liquid chromatography coupled with homogeneous liquid-liquid microextraction was developed for the determination of five triazine herbicides in infant milk powders. The ionic liquid was used as microextraction solvent. The separation of the herbicides was performed on an Eclipse XDB-C18 column using acetonitrile and water as mobile phases in gradient mode. The effects of homogeneous liquid-liquid extraction conditions on the experi-mental results were investigated in detail. Under the optimized experimental conditions,the cal-ibration curves for determining the analytes were linear and the correlation coefficients were ≥0. 999 2. The limits of detection for cyanazine,desmetryn,terbumeton,terbuthylazine and dim-ethametryn were 12. 1,13. 8,11. 8,14. 6 and 13. 7 μg/kg,respectively. The recoveries of the analytes spiked in four infant milk powders ranged from 92. 2% to 103. 2% and the relative standard deviations were lower than 6%. This method is sensitive,simple,and suitable for the determination of triazine herbicides in milk powder samples.

  7. Experimental and Numberical Investigations of Single Drop Mass Transfer in Solvent Extraction Systems with Resistance in Both Phases

    Institute of Scientific and Technical Information of China (English)

    LITianwen; FEIWeiyang; 等

    2002-01-01

    Numerical simulation of transient mass transfer to a single drop controlled by the internal resistance or by the resistance in both phases was mathematically formulated and simulated in a boundary-fitted orthogonal coordinate system. The siumlated results on the transient mass transfer dominated by the internal resistance are in good agreement with the Newman and Kronig-Brink models for drops with low Reynolds number. When the drop Reynolds number is up to 200, the mass transfer coefficient from numerical simulation is very low as compared with the Handlos-Baron model.The cases with mass transfer resistance residing in both the continuous and drop phases were simulated successfully and compared with the experimental data in three extraction systems recommended by European Confederation of Chemical Engineering (EFCE).For single drops with Re<200, the numerically predicted values of the extraction fraction and overall mass transfer coefficient are in reasonable coincidence with the experimental data.It is concluded that the numerical simulation can be resorted in some cases of solvent extraction for conducting numerical experiments and parametric study.Nevertheless, for better resolution as higher Reynolds number drops are simulated,more sophisticated techniques should be developed and incorporated to deal with the large deformation and transient shape oscillation as well as possible Marangoni effect.

  8. Experimental Study of the Ignition of Single Drops of Coal Suspensions and Coal Particles in the Oxidizer Flow

    Science.gov (United States)

    Vershinina, K. Yu.; Glushkov, D. O.; Kuznetsov, G. V.; Strizhak, P. A.

    2017-01-01

    An experimental study has been made of the process of ignition of single drops of water-coal and organic water-coal suspensions and coal particles heated by the oxidizer flow. The low-temperature (400-600°C) regime of the initiation of combustion of commensurate (from 1 to 3 mm) drops of water-coal and organic water-coal suspensions and coal particles has been considered. With the use of a high-speed (up to 105 frames/s) video camera and Tema Automative software, the influence of the oxidizer temperature, the gas flow velocity, the size of suspension fuel drops, and the coal particle size on the conditions and integral characteristics of the induction period has been determined. The ignition delay times and the duration of the combustion process of the investigated fuel samples have been established. The features of the stages of stable low-temperature initiation of combustion have been determined.

  9. Headspace in-tube microextraction coupled with micellar electrokinetic chromatography of neutral aromatic compounds.

    Science.gov (United States)

    Cho, Sung Min; Park, Bum Su; Jung, Woo Sung; Lee, Sang Won; Jung, Yunhwan; Chung, Doo Soo

    2016-02-01

    Headspace (HS) extraction can be carried out easily and aptly via single drop microextraction coupled with capillary electrophoresis (CE). However, one drawback is the difficulty of keeping the single drop stably at the capillary tip. To solve this problem, we have recently demonstrated HS in-tube microextraction (ITME) of acidic compounds such as chlrophenols in an acidic sample using a basic run buffer plug in the separation capillary for CE as an acceptor phase. In this report, an organic acceptor plug in a capillary was used to extract neutral organic volatile pollutants such as BTEX (benzene, toluene, ethylbenzene, and m-xylene). After extraction, the analytes enriched in the organic acceptor plug were analyzed with micellar electrokinetic chromatography (MEKC). The enrichment factors for BTEX in a standard solution were up to 350 under an optimal condition of 25°C for 20 min. As an application, BTEX spiked into bottled water were analyzed with HS-ITME-MEKC, and the enrichment factors for BTEX were up to 320. The limits of detections were 1-4 ppb, which are at least 200 times lower than the US Environmental Protection Agency guidelines for drinking water, except benzene. The entire procedure of HS-ITME-MEKC was carried out automatically using a commercial CE instrument.

  10. 离子液体掺杂聚苯胺固相微萃取涂层的电沉积制备及其在芳香胺检测中的应用%Electrochemical Preparation of Polyaniline-Ionic Liquid Based Solid Phase Microextraction Coating and Its Application in Determination of Aromatic Amines

    Institute of Scientific and Technical Information of China (English)

    王妹丽; 王娟; 赵发琼; 曾百肇

    2011-01-01

    新型萃取材料及相关涂层制备技术是固相微萃取技术发展的重点.本研究在1-羟丙基-3-甲基咪唑-四氟硼酸盐([C3(OH)mim][BF4])和HNO3混合溶液中,通过电化学方法在铂(Pt)丝表面固定新型聚苯胺-离子液体(PANI-IL)涂层.电镜分析表明,离子液体存在时,PANI膜孔结构变均匀、比表面积增大.以芳香胺为模拟物,考察萃取头的顶空固相微萃取(HS SPME)性能.在优化条件下,5种芳香胺的检出限为0.04~0.12μg/L(SIN=3);线性范围为0.15~1000 μg/L.同一萃取头萃取5次的相对标准偏差(RSD)小于4.6%;不同萃取头的RSD则在2.4%~9.5%(n=3)之间.与自制聚苯胺(PANI/Pt)及商品化的聚丙烯酸酯(PA)萃取头相比,PANI-IL/Pt萃取头具有更高的萃取率.此外,PANI-IL涂层对苯类化合物亦有较高的萃取能力.萃取头使用120余次后,萃取性能无明显变化,表明萃取头的稳定性好、使用寿命长.%A novel solid phase microextraction coating of polyaniline-ionic liquid (PANI-IL) was prepared by electrodeposition on a Pt wire in aqueous solutions containing ionic liquid [C3 (OH) mim][BF4] and nitric acid. The resulted coating was more uniform and porous than PANI coating. Taking five aromatic amines as models, the performance of the PANI-IL/Pt fiber was explored. Under the optimized conditions, when they were determined by GC after headspace SPME with the PANI-IL/Pt, the detection limits were 0. 04 - 0. 12 μg/L (S/N = 3) and the linear ranges were 0. 15 -1000 μg/L. These aromatic amines were determined for five times using a PANI-IL/Pt fiber coupled with GC and the RSD of chromatographic peak areas were smaller than 4.6% ; the fiber to fiber RSD was 2. 4-9. 5% for different aromatic amines. In comparison with PANI/Pt and commercial PA, the PANI-IL/Pt fiber showed higher extraction efficiency and repeatability. It also exhibited high extraction capability to benzene compounds. The PANI-IL/Pt fiber was used for more than 120

  11. Solid-phase microextraction

    DEFF Research Database (Denmark)

    Nilsson, Torben

    The objective of this study has been to develop new analytical methods using the rapid, simple and solvent-free extraction technique solid-phase microextraction (SPME) for the quantitative analysis of organic pollutants at trace level in drinking water and environmental samples. The dynamics...

  12. Ionic liquids based dispersive liquid-liquid microextraction coupled to gas chromatography for determination of aromatic hydrocarbons%基于离子液体的分散液液微萃取-气相色谱联用在苯系物分析中的应用

    Institute of Scientific and Technical Information of China (English)

    万晓星; 周兴旺; 汪敦佳

    2012-01-01

    通过改进气相色谱气化室,实现了离子液体分散液液微萃取与气相色谱的联用。以水不互溶的离子液体1-丁基-3-甲基咪唑六氟磷酸盐作为萃取剂,丙酮作为分散剂,能够从水溶液中有效地萃取苯系物。利用改进装置优化了苯、甲苯、乙苯的分散液液萃取及气相色谱分析条件,得到富集倍数为31~105,检出限为0.2~0.5μg/L.离子液体作为萃取剂在气相色谱进样后不产生溶剂干扰峰,且可回收重复利用。%The advantages of dipersive liquid-liquid microextraction(DLLME) coupled to gas chromatography are simplicity of operation,rapidity,low cost with high recovery rate and enrichment factor.Ionic liquids based DLLME coupled to gas chromatography for the simultaneous determination of diversified aromatic hydrocarbons was developed in this paper.The sample injection part of gas chromatographic instrument was modified to avoid the ionic liquid leaking into the chromatographic column.The parameters affecting extraction efficiency such as extractant,dispersive solvent,volume of the solvent and extraction time were studied.Under the optimum conditions,the enrichment factors ranged from 31 to 105.The linear range for the determination was 1-100 μg/L and the limits of detection were from 0.2 to 0.5 μg/L(S /N = 3),with the correlation coefficients(r) varying from 0.991 to 0.995.Using ionic liquid as extractantcan can effectively reduce the interference of solvent peak and enhance the extraction efficiency as well.

  13. On-line sample processing involving microextraction techniques as a front-end to atomic spectrometric detection for trace metal assays: A review

    Energy Technology Data Exchange (ETDEWEB)

    Miró, Manuel, E-mail: manuel.miro@uib.es [FI-TRACE Group, Department of Chemistry, Faculty of Sciences, University of the Balearic Islands, E-07122 Palma de Mallorca, Illes Balears (Spain); Hansen, Elo Harald [Granåsen 93, DK-2800 Kgs. Lyngby (Denmark)

    2013-06-11

    Graphical abstract: -- Highlights: •Role of flow injection in automation of microextraction techniques for metal assays. •On-line coupling of liquid phase microextraction (LPME) to atomic spectrometry. •Critical evaluation of on-line single drop and dispersive LPME. •On-line coupling of micro-solid phase extraction (μSPE) to atomic spectrometry. •Critical appraisal of magnetic/carbon nanoparticles and biomass for on-line μSPE. -- Abstract: Within the last decade, liquid-phase microextraction (LPME) and micro-solid phase extraction (μSPE) approaches have emerged as substitutes for conventional sample processing procedures for trace metal assays within the framework of green chemistry. This review surveys the progress of the state of the art in simplification and automation of microextraction approaches by harnessing to the various generations of flow injection (FI) as a front end to atomic absorption spectrometry (AAS), atomic fluorescence spectrometry (AFS) or inductively coupled plasma atomic emission spectrometry or mass spectrometry (ICP-AES/MS). It highlights the evolution of flow injection analysis and related techniques as vehicles for appropriate sample presentation to the detector and expedient on-line matrix separation and pre-concentration of trace levels of metals in troublesome matrices. Rather than being comprehensive this review is aimed at outlining the pros and cons via representative examples of recent attempts in automating green sample preparation procedures in an FI or sequential injection (SI) mode capitalizing on single-drop microextraction, dispersive liquid-phase microextraction and advanced sorptive materials including carbon and metal oxide nanoparticles, ion imprinted polymers, superparamagnetic nanomaterials and biological/biomass sorbents. Current challenges in the field are identified and the synergetic combination of flow analysis, nanotechnology and metal-tagged biomolecule detection is envisaged.

  14. A disposable screen-printed silver strip sensor for single drop analysis of halide in biological samples.

    Science.gov (United States)

    Chiu, Mei-Hsin; Cheng, Wan-Ling; Muthuraman, Govindan; Hsu, Cheng-Teng; Chung, Hsieh-Hsun; Zen, Jyh-Myng

    2009-06-15

    A screen-printed silver strip with three-electrode configuration of Ag-working, Ag-counter and Ag/Ag(x)O reference electrodes was developed for simultaneous determination of chloride, bromide and iodide in aqueous solutions. It was fabricated simply by screen-printing silver ink onto a polypropylene (PP) base. The in-situ prepared Ag/Ag(x)O reference electrode can avoid the leaching interference in chloride detection while using a conventional Ag/AgCl reference electrode. A single drop of analyte (50 microl) is enough to determine iodide, bromide and chloride by measuring the well-separated oxidation peak currents of respective silver halides. The calibration graph was linear from 10 microM to 20 mM for iodide and bromide and 100 microM to 20 mM for chloride and the detection limit (S/N=3) was 3.05 microM, 2.95 microM and 18.83 microM for iodide, bromide and chloride, respectively. The strip is designed to be disposable and as such manual polishing is not necessary. The proposed sensor is not only simple to manufacture and easy to operate but also fast and precise with little detection volume. It is successfully applied to the determination of halide ions in real samples.

  15. Retaining activity of enzymes after capture and extraction within a single-drop of biological fluid using immunoaffinity membranes.

    Science.gov (United States)

    Shimazaki, Youji; Sato, Yuki

    2016-05-15

    The purpose of this study was the measurement of enzyme activity within a single-drop of biological fluid after micropurification. Esterase and lactate dehydrogenase (LDH) retained their enzymatic activities after being captured by membrane-immobilized antibodies, which were prepared by non-denaturing two-dimensional electrophoresis, transferred to polyvinylidene difluoride and then stained by Ponceau S. The activities of both enzymes were also measured after being captured by antibodies and biotinylated antibodies bound to membrane-immobilized protein A or avidin, respectively. After esterase and LDH were captured from biological samples by membrane-immobilized protein A or avidin, their activities were semi-quantitatively measured on the surface of the membrane using fluorescence determination. More than 51% of enzyme activities were retained even after the enzymes were captured by biotinylated antibody bound to membrane-immobilized avidin and eluted by rinsing with 5μL of 1% Triton X-100, compared with the activities of the enzyme on the immunoaffinity membrane.

  16. Liquid phase microextraction for the analysis of trace elements and their speciation

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Bin, E-mail: binhu@whu.edu.cn; He, Man; Chen, Beibei; Xia, Linbo

    2013-08-01

    Trace/ultra-trace elements and their speciation analysis in complex matrices usually require sample preparation procedures to achieve sample clean-up and analyte preconcentration. Sample preparation is often the bottleneck in trace elements and their speciation analysis which has a direct impact on accuracy, precision and limits of detection and is often the rate-determining step of the analytical process. Recent trends in sample preparation include miniaturization, automation, high-throughput performance and reduction in solvent/sample consumption and operation time. Liquid-phase microextraction (LPME) technique as a novel and promising alternative in sample preparation can meet these requirements and has become a very efficient sample preparation technique. This review updates the state of art of LPME for trace elements and their speciation analysis and discusses its promising prospects. The major thrust of the article highlights the applications of LPME including single-drop microextraction (SDME), hollow fiber-liquid phase microextraction (HF-LPME), dispersive liquid liquid microextraction (DLLME) and solidified floating organic drop microextraction (SFODME) to the fields of elemental and their speciation analysis by atomic spectrometry-based methods, especially inductively coupled plasma mass spectrometry. General and specific concepts, different extraction formats and characteristics of LPME are described and compared, along with examples of recent innovations and applications presented to demonstrate its potential for trace elements and their speciation analysis in biological and environmental fields. Moreover, the application potential and an outlook on the combination of LPME and atomic spectrometry-based techniques for inorganic analysis are commentated. - Highlights: • The state of art of LPME for trace elements and their speciation analysis is updated. • Different extraction formats of LPME are described. • The application potential and future

  17. Dynamic microwave-assisted extraction combined with continuous-flow microextraction for determination of pesticides in vegetables.

    Science.gov (United States)

    Wu, Lijie; Hu, Mingzhu; Li, Zhanchao; Song, Ying; Yu, Cui; Zhang, Hanqi; Yu, Aimin; Ma, Qiang; Wang, Ziming

    2016-02-01

    A simple, rapid, solventless and cost-effective dynamic microwave-assisted extraction (DMAE) combined with continuous-flow microextraction (CFME) system was firstly assembled and validated for extraction of eight organophosphorus pesticides in vegetables. The method combines the advantages of DMAE and CFME, and extends the application of the single drop microextraction to complex solid samples. The extraction, separation, and enrichment were performed in a single step, which could greatly simplify the operation and reduce the whole pretreatment time. In the developed method, analytes were first extracted from the vegetables using 3% NaCl solution as extraction solvent, then concentrated into microextraction solvent. After extraction, the microextraction solvent containing the enriched analyte was directly analyzed by GC-MS without any filtration or clean-up process. Several parameters affecting the extraction efficiency were investigated and optimized. Real vegetable samples were analyzed, satisfactory recoveries were obtained in the range of 80.7-106.7%, and relative standard deviations were lower than 8.7%.

  18. Extensible automated dispersive liquid–liquid microextraction

    Energy Technology Data Exchange (ETDEWEB)

    Li, Songqing; Hu, Lu; Chen, Ketao; Gao, Haixiang, E-mail: hxgao@cau.edu.cn

    2015-05-04

    Highlights: • An extensible automated dispersive liquid–liquid microextraction was developed. • A fully automatic SPE workstation with a modified operation program was used. • Ionic liquid-based in situ DLLME was used as model method. • SPE columns packed with nonwoven polypropylene fiber was used for phase separation. • The approach was applied to the determination of benzoylurea insecticides in water. - Abstract: In this study, a convenient and extensible automated ionic liquid-based in situ dispersive liquid–liquid microextraction (automated IL-based in situ DLLME) was developed. 1-Octyl-3-methylimidazolium bis[(trifluoromethane)sulfonyl]imide ([C{sub 8}MIM]NTf{sub 2}) is formed through the reaction between [C{sub 8}MIM]Cl and lithium bis[(trifluoromethane)sulfonyl]imide (LiNTf{sub 2}) to extract the analytes. Using a fully automatic SPE workstation, special SPE columns packed with nonwoven polypropylene (NWPP) fiber, and a modified operation program, the procedures of the IL-based in situ DLLME, including the collection of a water sample, injection of an ion exchange solvent, phase separation of the emulsified solution, elution of the retained extraction phase, and collection of the eluent into vials, can be performed automatically. The developed approach, coupled with high-performance liquid chromatography–diode array detection (HPLC–DAD), was successfully applied to the detection and concentration determination of benzoylurea (BU) insecticides in water samples. Parameters affecting the extraction performance were investigated and optimized. Under the optimized conditions, the proposed method achieved extraction recoveries of 80% to 89% for water samples. The limits of detection (LODs) of the method were in the range of 0.16–0.45 ng mL{sup −1}. The intra-column and inter-column relative standard deviations (RSDs) were <8.6%. Good linearity (r > 0.9986) was obtained over the calibration range from 2 to 500 ng mL{sup −1}. The proposed

  19. Effect of Hydrophobicity on Splash Erosion by a Single Drop Impact: From Model Soil to Real Soil

    Science.gov (United States)

    Ahn, Sujung; Doerr, Stefan H.; Douglas, Peter; Bryant, Robert; Hamlett, Christopher A. E.; McHale, Glen; Newton, Michael I.; Shirtcliffe, Neil J.

    2013-04-01

    Splash erosion is soil loss caused by raindrop impacts and can be a dominating process in low precipitation events or on barely vegetated slopes. Water repellent soils have been reported to have greater splash loss by multiple drop impacts than wettable soils either due to effects of a water layer (Terry and Shakesby 1993) or a wet crust (Fox et al. 2007) generated by accumulation of water. In previous work, using homogeneous glass beads as model soil material, we found that the impact of a single water drop results in significantly different splash behaviour between hydrophobic and hydrophilic particles (Ahn et al. 2012). Natural soils are more variable in particle shape, surface texture and morphology than the model material used. The aim of the study presented here was to examine to what degree this difference in splash behaviour between hydrophobic and hydrophilic spherical glass particles applies to natural sandy soil material. Splash behaviour of beach sands was compared with that previously obtained for the model material (glass beads) using the same single drop impact test procedure (Ahn et al. 2012). The sand particles were in the same size range (350~400 µm diameter) and chemically modified with HCl and chlorotrimethylsilane in the same method applied to glass beads. A single water drop was released from 40 cm above the target and its impact was recorded using a high-speed video camera (976 fps). Overall, the amount of splash detachment was significantly lower (50~80%) for the beach sand than for glass beads in both hydrophobic and hydrophilic cases. However, the difference in the amount of splash detachment between hydrophobic and hydrophilic sand was 3 times larger than that of glass beads. Potential factors for lower net detachment and higher contrast, of sand compared to glass beads, might be (i) particle mobility and (ii) enhanced water repellency on rougher surfaces, respectively. Mobility experiments (angle of repose and flowability) showed that

  20. Numerical simulation of Marangoni effects of single drops induced by interphase mass transfer in liquid-liquid extraction systems by the level set method

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    The mathematical model of mass transfer-induced Marangoni effect is formulated. The drop surface evolution is captured by the level set method, in which the interface is represented by the embedded set of zero level of a scalar distance function defined in the whole computational domain. Numerical simulation of the Marangoni effect induced by interphase mass transfer to/from deformable single drops in unsteady motion in liquid-liquid extraction systems is performed in a Eulerian axisymmetric reference frame. The occurrence and development of the Marangoni effect are simulated, and the re- sults are in good agreement with the classical theoretical analysis and previous simulation.

  1. Numerical simulation of Marangoni effects of single drops induced by interphase mass transfer in liquid-liquid extraction systems by the level set method

    Institute of Scientific and Technical Information of China (English)

    WANG JianFeng; YANG Chao; MAO ZaiSha

    2008-01-01

    The mathematical model of mass transfer-induced Marangoni effect is formulated. The drop surface evolution is captured by the level set method, in which the interface is represented by the embedded set of zero level of a scalar distance function defined in the whole computational domain. Numerical simulation of the Marangoni effect induced by interphase mass transfer to/from deformable single drops in unsteady motion in liquid-liquid extraction systems is performed in a Eulerian axisymmetric reference frame. The occurrence and development of the Marangoni effect are simulated, and the re-sults are in good agreement with the classical theoretical analysis and previous simulation.

  2. The Application of Ionic Liquid-liquid Phase Microextraction in the Analysis of Environmental Contaminants%离子液体-液相微萃取法在环境污染物分析中的应用

    Institute of Scientific and Technical Information of China (English)

    唐倩倩; 相秉仁

    2012-01-01

    With the development of liquid-phase microextraction technology, in recent years, ionic liquids as extractant in liquid microextraction technology have been widely used for the analysis of environmental pollutants. This paper provides a brief overview of ionic liquids in three important sample-preparation techniques, namely, ionic liquid single drop microextraction, ionic liquid-hollow fiber membrane microextraction, and ionic liquid-liquid dispersions microextraction, and highlights the application in the analysis of environmental contaminants.%随着溶剂微萃取技术的发展,近年来,以离子液体为萃取剂的液相微萃取技术在环境污染物的检测中已经得到大量应用.该文对离子液体-液相微萃取的三种主要模式:离子液体-单液滴微萃取,离子液体-中空纤维膜微萃取,离子液体-分散液液微萃取进行了综述,并着重介绍了其在环境污染物分析中的应用.

  3. Multiple solid-phase microextraction

    NARCIS (Netherlands)

    Koster, EHM; de Jong, GJ

    2000-01-01

    Theoretical aspects of multiple solid-phase microextraction are described and the principle is illustrated with the extraction of lidocaine from aqueous solutions. With multiple extraction under non-equilibrium conditions considerably less time is required in order to obtain an extraction yield that

  4. Dispersive suspended microextraction.

    Science.gov (United States)

    Yang, Zhong-Hua; Liu, Yu; Lu, Yue-Le; Wu, Tong; Zhou, Zhi-Qiang; Liu, Dong-Hui

    2011-11-14

    A novel sample pre-treatment technique termed dispersive suspended microextraction (DSME) coupled with gas chromatography-flame photometric detection (GC-FPD) has been developed for the determination of eight organophosphorus pesticides (ethoprophos, malathion, chlorpyrifos, isocarbophos, methidathion, fenamiphos, profenofos, triazophos) in aqueous samples. In this method, both extraction and two phases' separation process were performed by the assistance of magnetic stirring. After separating the two phases, 1 μL of the suspended phase was injected into GC for further instrument analysis. Varieties of experiment factors which could affect the experiment results were optimized and the following were selected: 12.0 μL p-xylene was selected as extraction solvent, extraction speed was 1200 rpm, extraction time was 30 s, the restoration speed was 800 rpm, the restoration time was 8 min, and no salt was added. Under the optimum conditions, limits of detections (LODs) varied between 0.01 and 0.05 μg L(-1). The relative standard deviation (RSDs, n=6) ranged from 4.6% to 12.1%. The linearity was obtained by five points in the concentration range of 0.1-100.0 μg L(-1). Correlation coefficients (r) varied from 0.9964 to 0.9995. The enrichment factors (EFs) were between 206 and 243. In the final experiment, the developed method has been successfully applied to the determination of organophosphorus pesticides in wine and tap water samples and the obtained recoveries were between 83.8% and 101.3%. Compared with other pre-treatment methods, DSME has its own features and could achieve satisfied results for the analysis of trace components in complicated matrices.

  5. 液相微萃取技术在农药残留分析中的应用研究进展%Review on the application of liquid phase microextraction in pesticide residue analysis

    Institute of Scientific and Technical Information of China (English)

    王素利; 杨素萍; 刘丰茂; 薛佳莹; 尤祥伟

    2012-01-01

    Liquid phase microextraction (LPME) is one of novel sample pretreatment techniques which has many advantages such as quick, simple, economic, highly selective and accurate, less-solvent consuming and environmental friendly. It can be matched easily with most of analytical instruments. It includes several types such as single drop microextraction ( SDME) , hollow fiber liquid phase microextraction ( HF-LPME) , dispersive liquid-liquid microextraction ( DLLME ) , solidified floating organic drop microextraction ( SFODME) , continuous-flow microextraction ( CFME ) and directly-suspended droplet microextraction (DSDME) etc. It is a very potential sample pretreatment technique for theoretic and application studies. In this review, the historical development and overview of these miniaturized liquid phase extraction methodologies were discussed and a comprehensive collection of application of these methods for preconcentration and determination of pesticide residue in various matrices were summarized.%液相微萃取技术(LPME)是一种新型的样品前处理方法,具有快速、简单、廉价、选择性强、准确度高、溶剂消耗量少、环境污染小等优点,方便与各种分析仪器联用.其具有多种模式:单滴液相微萃取(SDME)、中空纤维液相微萃取(HF-LPME)、分散液相微萃取(DLLME)、悬浮固化液微萃取(SFODME)、连续流动微萃取(CFME)、直接悬挂液滴微萃取(DSDME)等,具有很好的研究潜力和应用前景.对液相微萃取技术在农药残留分析中的应用研究进展进行了综述.

  6. A comparison of liquid-based cytology with conventional cytology.

    Science.gov (United States)

    Celik, C; Gezginç, K; Toy, H; Findik, S; Yilmaz, O

    2008-02-01

    To evaluate the 2 methods of cytologic screening to detect abnormalities of the cervical epithelium. This study with 3 groups of women was performed at Selcuk University Meram Medical School between January 2004 and March 2006. In one group (paired sample for specimen collection) women were screened with conventional cytology; in another group (paired sample for specimen collection) they were screened with liquid-based cytology; and in the third group (split sample for specimen collection) they were screened by both methods. The rate of unsatisfactory results was lower in the liquid-based than in the conventional cytology group (6.1% vs. 2.6%; Pliquid-based method, but the difference was not statistically significant. Also, no statistically significant differences between liquid-based and conventional cytology were observed in the detection of other epithelial abnormalities (P>0.05). The liquid-based and conventional cytology methods were found to be equivalent in the detection of cervical epithelial abnormalities.

  7. Development of headspace solid-phase microextraction method for ...

    African Journals Online (AJOL)

    ... solid-phase microextraction method for the analysis of pesticide residues in fruit and ... Journal of Applied Sciences and Environmental Management ... interface temperature) and solid phase microextraction parameters (fiber coating type, ...

  8. Determination of diflubenzuron and chlorbenzuron in fruits by combining acetonitrile-based extraction with dispersive liquid-liquid microextraction followed by high-performance liquid chromatography.

    Science.gov (United States)

    Ruan, Chunqiang; Zhao, Xiang; Liu, Chenglan

    2015-09-01

    In this study, a simple and low-organic-solvent-consuming method combining an acetonitrile-partitioning extraction procedure followed by "quick, easy, cheap, effective, rugged and safe" cleanup with ionic-liquid-based dispersive liquid-liquid microextraction and high-performance liquid chromatography with diode array detection was developed for the determination of diflubenzuron and chlorbenzuron in grapes and pears. Ionic-liquid-based dispersive liquid-liquid microextraction was performed using the ionic liquid 1-hexyl-3-methylimidazolium hexafluorophosphate as the extractive solvent and acetonitrile extract as the dispersive solvent. The main factors influencing the efficiency of the dispersive liquid-liquid microextraction were evaluated, including the extractive solvent type and volume and the dispersive solvent volume. The validation parameters indicated the suitability of the method for routine analyses of benzoylurea insecticides in a large number of samples. The relative recoveries at three spiked levels ranged between 98.6 and 109.3% with relative standard deviations of less than 5.2%. The limit of detection was 0.005 mg/kg for the two insecticides. The proposed method was successfully used for the rapid determination of diflubenzuron and chlorbenzuron residues in real fruit samples.

  9. Liquid base cytology in evaluation of thyroid nodules.

    Science.gov (United States)

    Keyhani, Elahe; Sharghi, Sasan A; Amini, Rana; Sharghi, Sina A; Karimlou, Masoud; Moghaddam, Fatemeh A; Larijani, Bagher

    2014-01-01

    Palpable thyroid nodules are present in 4-7% of general population and Fine Needle Aspiration (FNA) is now accepted by endocrinologists and thyroid surgeons as a safe, simple and cost effective procedure for evaluating a thyroid nodule. The obtained sample can be spread directly on slides, processed as cell block preparations or prepared as liquid base smears. Liquid base method has been recently accepted due to its shorter preparation time and better preservation of nuclear details. The aim of this study is to compare the diagnostic results of two commonly used methods: Liquid Base Preparation and Cell Block Preparation in evaluation of thyroid nodules. The samples were taken from 100 patients with a solitary nodule or a prominent nodule on a multinodular goiter background (excluding hot nodules). The obtained samples were used to prepare conventional smears (CS), Cell Block Preparations (CBP) and Liquid Base Preparations (LBP). The slides were studied by two pathologists, considering the following parameters: Cellularity, Colloid, Lymphocytes/Plasma cells and Macrophages. 87% of cases revealed informative results in LBP method while in the same group of patients only 69% of samples were informative after processing by CBP method. Sensitivity and specificity of both methods compared with the conventional smears and with each other and it is concluded that LBP is a reliable method for evaluating of a thyroid nodule. Other studies also show the same results. The liquid base method should be trusted due to its easier procedure, cleaner slide background, its higher specificity and higher diagnostic yields. It can be used instead of CBP and in association with CS to increase the accuracy of evaluation of thyroid nodules.

  10. The recent developments in dispersive liquid–liquid microextraction for preconcentration and determination of inorganic analytes

    Directory of Open Access Journals (Sweden)

    H.M. Al-Saidi

    2014-12-01

    Full Text Available Recently, increasing interest on the use of dispersive liquid–liquid microextraction (DLLME developed in 2006 by Rezaee has been found in the field of separation science. DLLME is miniaturized format of liquid–liquid extraction in which acceptor-to-donor phase ratio is greatly reduced compared with other methods. In the present review, the combination of DLLME with different analytical techniques such as atomic absorption spectrometry (AAS, inductively coupled plasma-optical emission spectrometry (ICP-OES, gas chromatography (GC, and high-performance liquid chromatography (HPLC for preconcentration and determination of inorganic analytes in different types of samples will be discussed. Recent developments in DLLME, e.g., displacement-DLLME, the use of an auxiliary solvent for adjustment of density of extraction mixture, and the application of ionic liquid-based DLLME in determination of inorganic species even in the presence of high content of salts are presented in the present review. Finally, comparison of DLLME with the other liquid-phase microextraction approaches and limitations of this technique are provided.

  11. Use of an ionic liquid-based surfactant as pseudostationary phase in the analysis of carbamates by micellar electrokinetic chromatography.

    Science.gov (United States)

    Tejada-Casado, Carmen; Moreno-González, David; García-Campaña, Ana M; del Olmo-Iruela, Monsalud

    2015-03-01

    The applicability of an ionic liquid-based cationic surfactant 1-dodecyl-3-methyl-imidazolium tetrafluoroborate (C12 MImBF4 ) as pseudostationary phase in MEKC has been evaluated for the analysis of 11 carbamate pesticides (promecarb, carbofuran, metolcarb, fenobucarb, aldicarb, propoxur, asulam, benomyl, carbendazim, ethiofencarb, isoprocarb) in juice samples. Under optimum conditions (separation buffer, 35 mM NaHCO3 and 20 mM C12 MImBF4 , pH 9.0; capillary temperature 25°C; voltage -22 kV) the analysis was carried out in less than 12 min, using hydrodynamic injection (50 mbar for 7.5 s) and detection at 200 nm. For the extraction of these CRBs from juice samples, a dispersive liquid-liquid microextraction (DLLME) procedure has been proposed, by optimization of variables affecting the efficiency of the extraction. Following this treatment, sample throughput was approximately 12 samples per hour, obtaining a preconcentration factor of 20. Matrix-matched calibration curves were established using tomato juice as representative matrix (from 5 to 250 μg/L for CBZ, BY, PX, CF, FEN, ETH, ISP, and 25-250 μg/L for ASL, ALD, PRC, MTL), obtaining quantification limits ranging from 1 to 18 μg/L and recoveries from 70 to 96%, with RSDs lower than 9%.

  12. Liquid-based cytology in oral cavity squamous cell cancer.

    Science.gov (United States)

    Navone, Roberto; Pentenero, Monica; Gandolfo, Sergio

    2011-04-01

    Oral exfoliative cytology is a practical tool for early diagnosis of squamous cell carcinoma (OSCC) and potentially malignant lesion (OPML), but is not yet extensively used. A literature review evaluated conventional and liquid-based oral diagnostic cytology efficacy and efficiency. 'Special' techniques like liquid-based cytology, computer-assisted cytology, Oral CDx, DNA ploidy, immunocytochemistry, molecular analyses and microhistology were reviewed. Cytology was useful when diagnosing OSCC and OPML. Oral CDx may assess dysplastic changes in clinically suspicious (class I) lesions, with doubtful efficacy in apparently innocuous (class II) lesions. Flow and/or image cytometry and immunocytochemistry can identify markers for the prediction of evolution of the OPML to OSCC. Molecular biology can detect the minimal residual clonal population of cancer cells in field cancerization and oral mucosa surgical margins. Microhistology is a reliable first level test in class II lesions for selected cases requiring surgical biopsy. Conventional cytology helps in OSCC and OPML screening; liquid-based cytology gives better results, enhancing both sensitivity and specificity, and provides material for further investigation. Sampling with the 'curette technique' permits collection of 'accidental' tissue fragments used as microbiopsies and proved a useful first-level test for the management of class II OPML.

  13. Usefulness of liquid-based preparation in urine cytology.

    Science.gov (United States)

    Hwang, Eu Chang; Park, Seong Hoon; Jung, Seung Il; Kwon, Dong Deuk; Park, Kwangsung; Ryu, Soo Bang; Park, Chang Soo

    2007-07-01

    ThinPrep (TP), a liquid-based cytological and non-invasive technique to confirm the diagnosis of bladder cancer, is reported to be a better screening test than the conventional cytospin method. This study compared the new MonoPrep2 (MP), a liquid-based cytological technique, with TP for diagnosing bladder cancer. Between January 2003 and June 2004, urine samples from 284 patients were processed using the TP and MP methods. The cytological diagnosis and the determination of specimen quality were performed separately. The cytological diagnoses were classified into four categories: unsatisfactory, benign, borderline, and malignant. A subsequent biopsy was performed in 73 patients. The cytological diagnoses were compared with the biopsy results to evaluate the sensitivity and specificity of the two methods. Considering all the features examined, the overall specimen quality was comparable between the MP and TP techniques in the majority of cases. The rate of satisfactory specimens was 100% for TP and 98.6% for MP. The diagnostic capacity was similar between MP and TP. The overall sensitivities with MP and TP were 58.6 and 62.0%, respectively, and the specificities were 100 and 97.7%; the differences were not significant (P > 0.05). MP and TP produced comparable results in diagnosing bladder cancer. As MP is less expensive than TP, we recommend MP as an alternative liquid-based cytology method for use in bladder cancer screening.

  14. Optimization of a NH4PF6-enhanced, non-organic solvent, dual microextraction method for determination of phthalate metabolites in urine by high performance liquid chromatography.

    Science.gov (United States)

    Wu, Jia; Ye, Zhihan; Li, Xiaolong; Wang, Xuedong; Luo, Fangjun; Sheng, Bo; Li, Yiwei; Lyu, Jianxin

    2016-03-01

    In conventional ionic liquid-based dispersive liquid-liquid microextraction (IL-DLLME) procedures, most of the IL disperser remains in the aqueous phase resulting in low recovery for moderately and weakly polar analytes due to the "carry-over effect". Herein, we successfully developed a "NH4PF6-enhanced, non-organic solvent, dual microextraction" method (ANSDM) for pretreatment of phthalate (PAE) metabolites with weak to moderate polarity. This method utilized in situ reaction of NH4PF6 as an ion-exchange reagent and disperser to realize two microextractions after using [C8MIM]PF6 as an extraction solvent and [C4MIM]BF4 as a disperser for conventional DLLME. Single-factor experiments, a two-level full factorial experimental design and central composite design were applied for optimizing operational parameters using 3D response surfaces and contour lines. Under optimized conditions, the newly developed method provided high extraction recoveries (93.8-99.1%) and low LODs (ca. 0.3μgL(-1)) for three phthalate metabolites in human urine. The primary advantages of the ANSDM method include: (1) integration of in situ reaction and conventional DLLME techniques to effectively extract both weak and moderately polar pollutants simultaneously; (2) non-organic solvent use in the microextraction procedure making the process safer and more environmental friendly; and (3) a time-saving, simple operation that is fully compatibility with HPLC analysis. To the best of our knowledge, our group is the first to develop the "non-organic solvent, dual microextraction" method and it has great potential as a sample pre-treatment technique for organic pollutants with weak to moderate polarity in biological and environmental matrices.

  15. Combining drop-to-drop solvent microextraction with gas chromatography/mass spectrometry using electronic ionization and self-ion/molecule reaction method to determine methoxyacetophenone isomers in one drop of water.

    Science.gov (United States)

    Wu, Hui-Fen; Yen, Jyh-Hao; Chin, Chen-Che

    2006-03-01

    A novel analytical technique termed drop-to-drop solvent microextraction (DDSME) was developed to determine three methoxyacetophenone isomers in one drop of water, which were then detected by gas chromatography/mass spectrometry using electronic ionization mass spectrometry for quantification analysis and self-ion/molecule reaction/tandem mass spectrometry for isomer differentiation. The best optimum parameters for the DDSME technique were as follows: extraction time, 5 min; using toluene as the extraction solvent; volume of extraction solvent, 0.5 microL and no salt addition. The advantages of this method are rapidity, convenience, ease of operation, simplicity of the device, and extremely little solvent and sample consumption. The limit of detection (LOD) for this technique was 1 ng/mL. The relative standard deviation was less than 2.6% (n = 5). The linear range of the calibration curve of DDSME is from 0.01 to 5 microg/mL with correlation coefficient (r2) of >0.954. In the comparison of the LOD of DDSME with other sample pretreatment methods including liquid/liquid extraction (LLE), single-drop microextraction (SDME), solid-phase microextraction (SPME), and liquid-phase microextraction (LPME) using a dual gauge microsyringe with hollow fiber methods, this method shows much better in sensitivity than the LLE (25 ng/mL) and it is compatible with SDME (0.5 ng/mL), SPME (0.5 ng/mL), and LPME using a dual gauge microsyringe with a hollow fiber (1 ng/mL). However, DDSME was more convenient than the LPME using a dual gauge microsyringe with a hollow fiber method and much lower cost than the SPME technique.

  16. Dispersive liquid-liquid microextraction combined with graphite furnace atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Zeini Jahromi, Elham [Department of Analytical Chemistry, Faculty of Chemistry, Iran University of Science and Technology, Tehran (Iran, Islamic Republic of); Electroanalytical Chemistry Research Center, Iran University of Science and Technology, Tehran (Iran, Islamic Republic of); Bidari, Araz [Department of Analytical Chemistry, Faculty of Chemistry, Iran University of Science and Technology, Tehran (Iran, Islamic Republic of); Electroanalytical Chemistry Research Center, Iran University of Science and Technology, Tehran (Iran, Islamic Republic of); Assadi, Yaghoub [Department of Analytical Chemistry, Faculty of Chemistry, Iran University of Science and Technology, Tehran (Iran, Islamic Republic of) and Electroanalytical Chemistry Research Center, Iran University of Science and Technology, Tehran (Iran, Islamic Republic of)]. E-mail: y_assadi@iust.ac.ir; Milani Hosseini, Mohammad Reza [Department of Analytical Chemistry, Faculty of Chemistry, Iran University of Science and Technology, Tehran (Iran, Islamic Republic of); Electroanalytical Chemistry Research Center, Iran University of Science and Technology, Tehran (Iran, Islamic Republic of); Jamali, Mohammad Reza [Department of Analytical Chemistry, Faculty of Chemistry, Iran University of Science and Technology, Tehran (Iran, Islamic Republic of); Electroanalytical Chemistry Research Center, Iran University of Science and Technology, Tehran (Iran, Islamic Republic of)

    2007-03-07

    Dispersive liquid-liquid microextraction (DLLME) technique was successfully used as a sample preparation method for graphite furnace atomic absorption spectrometry (GF AAS). In this extraction method, 500 {mu}L methanol (disperser solvent) containing 34 {mu}L carbon tetrachloride (extraction solvent) and 0.00010 g ammonium pyrrolidine dithiocarbamate (chelating agent) was rapidly injected by syringe into the water sample containing cadmium ions (interest analyte). Thereby, a cloudy solution formed. The cloudy state resulted from the formation of fine droplets of carbon tetrachloride, which have been dispersed, in bulk aqueous sample. At this stage, cadmium reacts with ammonium pyrrolidine dithiocarbamate, and therefore, hydrophobic complex forms which is extracted into the fine droplets of carbon tetrachloride. After centrifugation (2 min at 5000 rpm), these droplets were sedimented at the bottom of the conical test tube (25 {+-} 1 {mu}L). Then a 20 {mu}L of sedimented phase containing enriched analyte was determined by GF AAS. Some effective parameters on extraction and complex formation, such as extraction and disperser solvent type and their volume, extraction time, salt effect, pH and concentration of the chelating agent have been optimized. Under the optimum conditions, the enrichment factor 125 was obtained from only 5.00 mL of water sample. The calibration graph was linear in the rage of 2-20 ng L{sup -1} with detection limit of 0.6 ng L{sup -1}. The relative standard deviation (R.S.D.s) for ten replicate measurements of 20 ng L{sup -1} of cadmium was 3.5%. The relative recoveries of cadmium in tap, sea and rivers water samples at spiking level of 5 and 10 ng L{sup -1} are 108, 95, 87 and 98%, respectively. The characteristics of the proposed method have been compared with cloud point extraction (CPE), on-line liquid-liquid extraction, single drop microextraction (SDME), on-line solid phase extraction (SPE) and co-precipitation based on bibliographic data

  17. Development of a rapid screening technique for organochlorine pesticides using solvent microextraction (SME) and fast gas chromatography (GC).

    Science.gov (United States)

    de Jager, L S; Andrews, A R

    2000-11-01

    A novel, fast screening method for organochlorine pesticides (OCPs) in water samples has been developed. Total analysis time was less than 9 min, allowing 11 samples to be screened per hour. The relatively new technique of solvent microextraction (SME) was used to extract and preconcentrate the pesticides into a single drop of hexane. The use of a conventional carbon dioxide cryotrap was investigated for introduction of the extract onto a micro-bore (0.1 mm) capillary column for fast GC analysis. A pulsed-discharge electron capture detector was used which yielded selective and sensitive measurement of the pesticide peaks. Fast GC conditions were optimised and tested with the previously developed SME procedure. Calibration curves yielded good linearity and concentrations down to 0.25 ng mL-1 were detectable with RSD values ranging from 12.0 to 28% and LOD for most OCPs at 0.25 ng mL-1. Spiked river water samples were tested and using the developed screen we were able to differentiate between spiked samples and samples containing no OCPs.

  18. Newly developed liquid-based cytology. TACAS™: cytological appearance and HPV testing using liquid-based sample.

    Science.gov (United States)

    Kubushiro, Kaneyuki; Taoka, Hideki; Sakurai, Nobuyuki; Yamamoto, Yasuhiro; Kurasaki, Akiko; Asakawa, Yasuyuki; Iwahara, Minoru; Takahashi, Kei

    2011-09-01

    Cell profiles determined by the thin-layer advanced cytology assay system (TACAS™), a liquid-based cytology technique newly developed in Japan, were analyzed in this study. Hybrid capture 2 (HC-2) was also performed using the liquid-based samples prepared by TACAS to ascertain its ability to detect human papillomavirus (HPV). Cell collection samples from uterine cervix were obtained from 359 patients and examined cytologically. A HC-2 assay for HPV was carried out in the cell specimens. All specimens were found to show background factors such as leukocytes. After excluding the 5 unsatisfactory cases from the total 354 cases, 82 cases (23.2%) were positive and 272 cases (76.8%) were negative for HPV. Cell specimens from 30 HPV-positive cases and 166 HPV-negative cases were subjected to 4 weeks of preservation at room temperature. Then, when subsequently re-assayed, 28 cases (93.3%) in the former group were found to be HPV positive and 164 cases (98.8%) in the latter group were found to be HPV negative. These results supported the excellent reproducibility of TACAS for HPV testing. A reasonable inference from the foregoing analysis is that TACAS may be distinguished from other liquid-based cytological approaches, such as ThinPrep and SurePath, in that it can retain the cell backgrounds. Furthermore, this study raises the possibility that cell specimens prepared using TACAS could be preserved for at least 4 weeks prior to carrying out a HC-2 assay for HPV.

  19. Liquid-based endometrial cytology: the Florence and Bari experience.

    Science.gov (United States)

    Buccoliero, A M; Resta, L; Napoli, A; Taddei, G L

    2009-04-01

    Several diagnostic procedures are available to investigate the endometrium, i.e. sonography, hysteroscopy, biopsy, endometrial curettage and cytology. Among these, endometrial cytology is less commonly utilized. Although the use of cytology in the diagnosis of endometrial adenocarcinoma has already been proposed due to its low cost and simple execution, a general consensus has not been reached. The improvement of the diagnostic capacity of endometrial cytology following the introduction of a liquid-based method suggests that this test should be routinely used in endometrial diagnosis. The main advantages of this method are the reduction in confounding factors, the distribution of cells on a thin layer and the possibility to obtain more slides from the same sample. The aim of this article is to focus on the methodological procedures and diagnostic criteria in liquid-based endometrial cytology based on the experience in two Italian centres: Department of Pathology, University of Bari and Department of Human Pathology and Oncology, University of Florence. The sampling method used by the Bari authors consists in the collection of liquid for uterine distension during hysteroscopy, while the Florence group used an endometrial brush. The sensitivity and specificity at Bari were 75% and 83%, respectively, and were 94-100% and 95-100% at Florence, respectively. Endometrial cytology provided sufficient diagnostic material significantly more often than biopsy. We thus propose that endometrial cytology can be used in routine diagnosis either alone or in association with other diagnostic procedures in order to improve diagnostic accuracy.

  20. Ionic liquid-based stable nanofluids containing gold nanoparticles.

    Science.gov (United States)

    Wang, Baogang; Wang, Xiaobo; Lou, Wenjing; Hao, Jingcheng

    2011-10-01

    A one-phase and/or two-phase method were used to prepare the stable ionic liquid-based nanofluids containing same volume fraction but different sizes or surface states of gold nanoparticles (Au NPs) and their thermal conductivities were investigated in more detail. Five significant experiment parameters, i.e. temperature, dispersion condition, particle size and surface state, and viscosity of base liquid, were evaluated to supply experimental explanations for heat transport mechanisms. The conspicuously temperature-dependent and greatly enhanced thermal conductivity under high temperatures verify that Brownian motion should be one key effect factor in the heat transport processes of ionic liquid-based gold nanofluids. While the positive influences of proper aggregation and the optimized particle size on their thermal conductivity enhancements under some specific conditions demonstrate that clustering may be another critical effect factor in heat transport processes. Moreover, the remarkable difference of the thermal conductivity enhancements of the nanofluids containing Au NPs with different surface states could be attributed to the surface state which has a strong correlation with not only Brownian motion but also clustering. Whilst the close relationship between their thermal conductivity enhancements and the viscosity of base liquid further indicate Brownian motion must occupy the leading position among various influencing factors. Finally, a promisingly synergistic effect of Brownian motion and clustering based on experimental clues and theoretical analyses was first proposed, justifying different mechanisms are sure related. The results may shed lights on comprehensive understanding of heat transport mechanisms in nanofluids.

  1. An ionic liquid based strain sensor for large displacement measurement.

    Science.gov (United States)

    Keulemans, Grim; Ceyssens, Frederik; Puers, Robert

    2017-03-01

    A robust and low cost ionic liquid based strain sensor is fabricated for high strain measurements in biomedical applications (up to 40 % and higher). A tubular 5 mm long silicone microchannel with an inner diameter of 310 µm and an outer diameter of 650 µm is filled with an ionic liquid. Three ionic liquids have been investigated: 1-butyl-1-methylpyrrolidinium bis (trifluoromethylsulfonyl) imide, ethylammonium nitrate and cholinium ethanoate. When the channel is axially stretched, geometrical deformations change the electrical impedance of the liquid channel. The sensors display a linear response and low hysteresis with an average gauge factors of 1.99 for strains up to 40 %. Additionally, to fix the sensor by surgical stitching to soft biological tissue, a sensor with tube clamps consisting of photopatternable SU-8 epoxy-based resin is proposed.

  2. Thermoreversible (Ionic-Liquid-Based) Aqueous Biphasic Systems.

    Science.gov (United States)

    Passos, Helena; Luís, Andreia; Coutinho, João A P; Freire, Mara G

    2016-02-04

    The ability to induce reversible phase transitions between homogeneous solutions and biphasic liquid-liquid systems, at pre-defined and suitable operating temperatures, is of crucial relevance in the design of separation processes. Ionic-liquid-based aqueous biphasic systems (IL-based ABS) have demonstrated superior performance as alternative extraction platforms, and their thermoreversible behaviour is here disclosed by the use of protic ILs. The applicability of the temperature-induced phase switching is further demonstrated with the complete extraction of two value-added proteins, achieved in a single-step. It is shown that these temperature-induced mono(bi)phasic systems are significantly more versatile than classical liquid-liquid systems which are constrained by their critical temperatures. IL-based ABS allow to work in a wide range of temperatures and compositions which can be tailored to fit the requirements of a given separation process.

  3. Gas flow headspace liquid phase microextraction.

    Science.gov (United States)

    Yang, Cui; Qiu, Jinxue; Ren, Chunyan; Piao, Xiangfan; Li, Xifeng; Wu, Xue; Li, Donghao

    2009-11-06

    There is a trend towards the use of enrichment techniques such as microextraction in the analysis of trace chemicals. Based on the theory of ideal gases, theory of gas chromatography and the original headspace liquid phase microextraction (HS-LPME) technique, a simple gas flow headspace liquid phase microextraction (GF-HS-LPME) technique has been developed, where the extracting gas phase volume is increased using a gas flow. The system is an open system, where an inert gas containing the target compounds flows continuously through a special gas outlet channel (D=1.8mm), and the target compounds are trapped on a solvent microdrop (2.4 microL) hanging on the microsyringe tip, as a result, a high enrichment factor is obtained. The parameters affecting the enrichment factor, such as the gas flow rate, the position of the microdrop, the diameter of the gas outlet channel, the temperatures of the extracting solvent and of the sample, and the extraction time, were systematically optimized for four types of polycyclic aromatic hydrocarbons. The results were compared with results obtained from HS-LPME. Under the optimized conditions (where the extraction time and the volume of the extracting sample vial were fixed at 20min and 10mL, respectively), detection limits (S/N=3) were approximately a factor of 4 lower than those for the original HS-LPME technique. The method was validated by comparison of the GF-HS-LPME and HS-LPME techniques using data for PAHs from environmental sediment samples.

  4. Beyond dispersive liquid-liquid microextraction.

    Science.gov (United States)

    Leong, Mei-I; Fuh, Ming-Ren; Huang, Shang-Da

    2014-03-28

    Dispersive liquid-liquid microextraction (DLLME) and other dispersion liquid-phase microextraction (LPME) methods have been developed since the first DLLME method was reported in 2006. DLLME is simple, rapid, and affords high enrichment factor, this is due to the large contact surface area of the extraction solvent. DLLME is a method suitable for the extraction in many different water samples, but it requires using chlorinated solvents. In recent years, interest in DLLME or dispersion LPME has been focused on the use of low-toxicity solvents and more conveniently practical procedures. This review examines some of the most interesting developments in the past few years. In the first section, DLLME methods are separated in two categories: DLLME with low-density extraction solvent and DLLME with high-density extraction solvent. Besides these methods, many novel special devices for collecting low-density extraction solvent are also mentioned. In addition, various dispersion techniques with LPME, including manual shaking, air-assisted LPME (aspirating and injecting the extraction mixture by syringe), ultrasound-assisted emulsification, vortex-assisted emulsification, surfactant-assisted emulsification, and microwave-assisted emulsification are described. Besides the above methods, combinations of DLLME with other extraction techniques (solid-phase extraction, stir bar sorptive extraction, molecularly imprinted matrix solid-phase dispersion and supercritical fluid extraction) are introduced. The combination of nanotechnique with DLLME is also introduced. Furthermore, this review illustrates the application of DLLME or dispersion LPME methods to separate and preconcentrate various organic analytes, inorganic analytes, and samples.

  5. Study on Micro-extraction Column of Uranium

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    <正>Some samples of uranium are very complicated therefore they can not be determined directly by analysis instrument, so pretreatment is necessary. The micro-extraction column of uranium is a kind of

  6. Membrane-based microextraction techniques in analytical chemistry: A review.

    Science.gov (United States)

    Carasek, Eduardo; Merib, Josias

    2015-06-23

    The use of membrane-based sample preparation techniques in analytical chemistry has gained growing attention from the scientific community since the development of miniaturized sample preparation procedures in the 1990s. The use of membranes makes the microextraction procedures more stable, allowing the determination of analytes in complex and "dirty" samples. This review describes some characteristics of classical membrane-based microextraction techniques (membrane-protected solid-phase microextraction, hollow-fiber liquid-phase microextraction and hollow-fiber renewal liquid membrane) as well as some alternative configurations (thin film and electromembrane extraction) used successfully for the determination of different analytes in a large variety of matrices, some critical points regarding each technique are highlighted.

  7. Accurate assessment of cell density in low cellular liquid-based cervical cytology

    NARCIS (Netherlands)

    Siebers, A.G.; Laak, J.A.W.M. van der; Huberts-Manders, R.; Vedder, J.E.M.; Bulten, J.

    2013-01-01

    A. G. Siebers, J. A. W. M. van der Laak, R. Huberts-Manders, J. E. M. Vedder and J. Bulten Accurate assessment of cell density in low cellular liquid-based cervical cytology Objective: Scant cellularity is the most important source of unsatisfactory liquid-based cytology. Although still being debate

  8. Accurate assessment of cell density in low cellular liquid-based cervical cytology

    NARCIS (Netherlands)

    Siebers, A.G.; Laak, J.A.W.M. van der; Huberts-Manders, R.; Vedder, J.E.M.; Bulten, J.

    2013-01-01

    A. G. Siebers, J. A. W. M. van der Laak, R. Huberts-Manders, J. E. M. Vedder and J. Bulten Accurate assessment of cell density in low cellular liquid-based cervical cytology Objective: Scant cellularity is the most important source of unsatisfactory liquid-based cytology. Although still being debate

  9. Screening of lignan patterns in Schisandra species using ultrasonic assisted temperature switch ionic liquid microextraction followed by UPLC-MS/MS analysis.

    Science.gov (United States)

    Dong, Wei; Yu, Shuijing; Deng, Yangwu; Pan, Tao

    2016-01-01

    The ultrasonic assisted temperature-switch ionic liquid microextraction (UATS-ILME) has been successfully applied in extracting of seven lignans from Schisandra. 1-Butyl-3-methylimidazolium tetrafluoroborate ([C4MIM][BF4]) aqueous solution was selected for extracting the target analytes in raw material at 80°C. The lignans were deposited into a single drop by in situ forming 1-butyl-3-methylimidazolium hexafluorophosphate ([C4MIM][PF6]) by cooling down to 0°C and centrifuging for 10min. The extracts were analyzed by ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) in a robust multiple-reaction monitoring (MRM) mode in five minutes. Meanwhile, the proposed method was validated and successfully applied to the determination of seven lignans in twelve Schisandra species. The results indicated that UATS-ILME combined with UPLC-MS/MS is a powerful and practical tool, which has great potential for comprehensive quality control of herbal medicines.

  10. Single-Drop Solution Electrode Discharge-Induced Cold Vapor Generation Coupling to Matrix Solid-Phase Dispersion: A Robust Approach for Sensitive Quantification of Total Mercury Distribution in Fish.

    Science.gov (United States)

    Chen, Qian; Lin, Yao; Tian, Yunfei; Wu, Li; Yang, Lu; Hou, Xiandeng; Zheng, Chengbin

    2017-02-07

    Sensitive quantification of mercury distribution in fish is challenging because of insufficient sensitivities of conventional analytical methods, the limited mass of organs (tens of micrograms to several milligrams), and dilution of analyte concentration from sample digestion. In this work, a simple and robust approach coupling multiwall carbon nanotubes assisted matrix solid-phase dispersion (MWCNTs-MSPD) to single-drop solution electrode glow discharge-induced cold vapor generation (SD-SEGD-CVG) was developed for the sensitive determination of mercury in limited amount of sample. Mercury species contained in a limited amount of sample can be efficiently extracted into a 100 μL of eluent by MWCNTs-MSPD, which are conveniently converted to Hg(0) by SD-SEGD-CVG and further transported to atomic fluorescence spectrometry for their determination. Therefore, analyte dilution resulted from sample preparation is avoided and sensitivity is significantly improved. On the basis of consumption of 1 mg of sample, a limit of detection of 0.01 μg L(-1) (0.2 pg) was obtained with relative standard deviations (RSDs) of 5.2% and 4.6% for 2 and 20 μg L(-1), respectively. The accuracy of the proposed method was validated by analysis of three Certified Reference Materials with satisfying results. To confirm that SD-SEGD-CVG-AFS coupling to MWCNTs-MSPD is a promising method to quantify mercury distribution in fish, this method was successfully applied for the sensitive determination of mercury in seven organs of common carps (muscle, gill, intestine, liver, gallbladder, brain, and eye) after dietary of mercury species. The proposed method provides advantages of minimum sample dilution, low blank, high sample introduction efficiency, high sensitivity, and minimum toxic chemicals and sample consumption.

  11. Solid phase microextraction device using aerogel

    Science.gov (United States)

    Miller, Fred S.; Andresen, Brian D.

    2005-06-14

    A sample collection substrate of aerogel and/or xerogel materials bound to a support structure is used as a solid phase microextraction (SPME) device. The xerogels and aerogels may be organic or inorganic and doped with metals or other compounds to target specific chemical analytes. The support structure is typically formed of a glass fiber or a metal wire (stainless steel or kovar). The devices are made by applying gel solution to the support structures and drying the solution to form aerogel or xerogel. Aerogel particles may be attached to the wet layer before drying to increase sample collection surface area. These devices are robust, stable in fields of high radiation, and highly effective at collecting gas and liquid samples while maintaining superior mechanical and thermal stability during routine use. Aerogel SPME devices are advantageous for use in GC/MS analyses due to their lack of interfering background and tolerance of GC thermal cycling.

  12. Comparison of liquid-based cytology with conventional cytology for detection of cervical cancer precursors: a randomized controlled trial.

    NARCIS (Netherlands)

    Siebers, A.G.; Klinkhamer, P.J.; Grefte, J.M.M.; Massuger, L.F.A.G.; Vedder, J.E.; Beijers-Broos, A.; Bulten, J.; Arbyn, M.

    2009-01-01

    CONTEXT: Liquid-based cytology has been developed as an alternative for conventional cervical cytology. Despite numerous studies and systematic reviews, controversy remains about its diagnostic accuracy. OBJECTIVE: To assess the performance of liquid-based cytology compared with conventional

  13. [Diagnosis of amniotic fluid embolism with blood samples by liquid-based cytology technique].

    Science.gov (United States)

    Liu, Bao-qin; Deng, Jian-qiang; Hou, An-chao; Cai, Ji-feng

    2014-12-01

    To establish the diagnosis of amniotic fluid embolism with blood samples by liquid-based cytology technique and to study the validity of method. The blood samples were collected from patients who suffered from amniotic fluid embolism. The components of amniotic fluid in blood samples were examined with blood smear by two direct smear methods (supernatant smear, sediment smear) and two liquid-based cytology methods (automatic smear, manual smear). The positive detection rate of each method was calculated. The positive detection rates of two liquid-based cytology methods (84.6% and 92.3%, respectively) were much higher than those of two direct methods (53.8% and 61.5%, respectively). The liquid-based cytology technique could improve the positive detection rate of amniotic fluid embolism.

  14. Liquid-Based Cytology in Fine-Needle Aspiration Biopsies of the Thyroid Gland

    National Research Council Canada - National Science Library

    Fadda, Guido; Rossi, Esther Diana

    2011-01-01

    ...: Liquid-based cytology (LBC) is a semiautomated device that has recently become widely available and has gained popularity as a method of collecting and processing both gynecologic and nongynecologic cytologic specimens...

  15. Comparison of centrifuged liquid based cytology method with conventional brush cytology in oral lesions

    OpenAIRE

    Nidhi Dwivedi; Akhil Agarwal; Vineet Raj; Bina Kashyap; Shaleen Chandra

    2012-01-01

    Background: Exfoliative cytology is the study of cells that are shed or scrapped off from mucosal surfaces. Centrifuged Liquid based cytology is a modified technique employed in the present study. Aims: To compare the utility of centrifuged liquid based cytology with conventional cytology in oral lesions after staining with Papanicolaou (PAP) stain. Materials and Methods: 50 cases of oral lesions comprising of normal mucosa (n=14), hyperkeratotic lesions (n=17), ulcerated lesions (n=7) and at...

  16. Overview of nongynecological samples prepared with liquid-based cytology medium.

    Science.gov (United States)

    Ren, Shuyue; Solomides, Charalambos; Draganova-Tacheva, Rossitza; Bibbo, Marluce

    2014-01-01

    Liquid-based cytology of nongynecological specimens is commonly used in cytology laboratories throughout the world and various processing methods, such as ThinPrep and SurePath, have been reported. The cytological features and performance of liquid-based cytology for various cytology specimens, including body cavity fluids, urine, brushing specimens and fine-needle aspiration of various lesions, were reviewed and compared with the experience of our laboratory and the literature published in PubMed. The parameters for the evaluation of liquid-based cytology and conventional smears were described in the various types of specimens. Criteria for the interpretation of nongynecological liquid-based cytology were highlighted to show differences in cell morphology, background and artifacts. The interpretation requires familiarity with the appearance of liquid-based cytology in the various types of preparations to avoid misdiagnosis. Cell blocks can be prepared with specimens preserved in a liquid-based cytology medium and immunocytochemical stains and molecular testing can be successfully performed. These are important adjuncts in order to reach a definitive diagnosis.

  17. Ionic liquid ultrasound assisted dispersive liquid-liquid microextraction method for preconcentration of trace amounts of rhodium prior to flame atomic absorption spectrometry determination

    Energy Technology Data Exchange (ETDEWEB)

    Molaakbari, Elaheh [Chemistry Department, Shahid Bahonar University of Kerman, Kerman (Iran, Islamic Republic of); Young Research Society, Shahid Bahonar University of Kerman, Kerman (Iran, Islamic Republic of); Mostafavi, Ali, E-mail: mostafavi.ali@gmail.com [Chemistry Department, Shahid Bahonar University of Kerman, Kerman (Iran, Islamic Republic of); Afzali, Daryoush [Environment and Nanochemistry Department, Research Institute of Environmental Science, International Center for Science, High Technology and Environmental Science, Kerman (Iran, Islamic Republic of); Mineral Industries Research Center, Shahid Bahonar University of Kerman, Kerman (Iran, Islamic Republic of)

    2011-01-30

    In this article, we consider ionic liquid based ultrasound-assisted dispersive liquid-liquid microextraction of trace amounts of rhodium from aqueous samples and show that this is a fast and reliable sample pre-treatment for the determination of rhodium ions by flame atomic absorption spectrometry. The Rh(III) was transferred into its complex with 2-(5-bromo-2-pyridylazo)-5-diethylamino phenol as a chelating agent, and an ultrasonic bath with the ionic liquid, 1-octyl-3-methylimidazolium bis (trifluoromethylsulfonyl) imide at room temperature was used to extract the analyte. The centrifuged rhodium complex was then enriched in the form of ionic liquid droplets and prior to its analysis by flame atomic absorption spectrometry, 300 {mu}L ethanol was added to the ionic liquid-rich phase. Finally, the influence of various parameters on the recovery of Rh(III) was optimized. Under optimum conditions, the calibration graph was linear in the range of 4.0-500.0 ng mL{sup -1}, the detection limit was 0.37 ng mL{sup -1} (3S{sub b}/m, n = 7) and the relative standard deviation was {+-}1.63% (n = 7, C = 200 ng mL{sup -1}). The results show that ionic liquid based ultrasound assisted dispersive liquid-liquid microextraction, combined with flame atomic absorption spectrometry, is a rapid, simple, sensitive and efficient analytical method for the separation and determination of trace amounts of Rh(III) ions with minimum organic solvent consumption.

  18. Conductive polymer-based microextraction methods: a review.

    Science.gov (United States)

    Bagheri, Habib; Ayazi, Zahra; Naderi, Mehrnoush

    2013-03-12

    Conductive polymers (CPs) are classified as materials which exhibit highly reversible redox behavior and the unusual combined properties of metal and plastics. CPs, due to their multifunctionality, ease of synthesis and their stability, have attracted more attentions in different fields of research, including sample preparation. CPs along with several commercial hydrophilic sorbents, are alternative to the commercially available hydrophobic sorbents which despite their high specific surface areas, have poor interactions and retentions in the extraction of polar compounds. This review covers a general overview regarding the recent progress and new applications of CPs toward their synthesis and use in novel extraction and microextraction techniques including solid phase microextraction (SPME), electrochemically controlled solid-phase microextraction (EC-SPME) and other relevant techniques. Furthermore the contribution of nano-structured CPs in these methodologies is also reviewed.

  19. Recent Microextraction Techniques for Determination and Chemical Speciation of Selenium

    Directory of Open Access Journals (Sweden)

    Ibrahim Ahmed S. A.

    2017-05-01

    Full Text Available Research designed to improve extraction has led to the development of microextraction techniques (ME, which involve simple, low cost, and effective preconcentrationof analytes in various matrices. This review is concerned with the principles and theoretical background of ME, as well as the development of applications for selenium analysis during the period from 2008 to 2016. Among all ME, dispersive liquid-liquid microextraction was found to be most favorable for selenium. On the other hand, atomic absorption spectrometry was the most frequently used instrumentation. Selenium ME have rarely been coupled to spectrophotometry and X-ray spectrophotometry methods, and there is no published application of ME with electrochemical techniques. We strongly support the idea of using a double preconcentration process, which consists of microextraction prior to preconcentration, followed by selenium determination using cathodic stripping voltammetry (ME-CSV. More attention should focus on the development of accurate, precise, and green methods for selenium analysis.

  20. Quantitation of antioxidants in water samples using ionic liquid dispersive liquid-liquid microextraction followed by high-performance liquid chromatography-ultraviolet detection.

    Science.gov (United States)

    Sobhi, Hamid Reza; Kashtiaray, Amir; Farahani, Hadi; Farahani, Mohammad Reza

    2011-01-01

    A simple and efficient method, ionic liquid-based dispersive liquid-liquid microextraction combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV), has been applied for the extraction and determination of some antioxidants (Irganox 1010, Irganox 1076 and Irgafos 168) in water samples. The microextraction efficiency factors were investigated and optimized: 1-hexyl-3-methylimidazolium hexafluorophosphate [C(6)MIM][PF(6)] (0.06 g) as extracting solvent, methanol (0.5 mL) as disperser solvent without salt addition. Under the selected conditions, enrichment factors up to 48-fold, limits of detection (LODs) of 5.0-10.0 ng/mL and dynamic linear ranges of 25-1500 ng/mL were obtained. A reasonable repeatability (RSD≤11.8%, n=5) with satisfactory linearity (r(2)≥0.9954) of the results illustrated a good performance of the presented method. The accuracy of the method was tested by the relative recovery experiments on spiked samples, with results ranging from 85 to 118%. Finally, the method was successfully applied for determination of the analytes in several real water samples. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Ultrasound-assisted ionic liquid-based micellar extraction combined with microcrystalline cellulose as sorbent in dispersive microextraction for the determination of phenolic compounds in propolis.

    Science.gov (United States)

    Cao, Jun; Peng, Li-Qing; Du, Li-Jing; Zhang, Qi-Dong; Xu, Jing-Jing

    2017-04-22

    An ionic liquid-(IL) based micellar extraction combined with microcrystalline cellulose- (MCC) assisted dispersive micro solid-phase extraction method was developed to extract phenolic compounds from propolis. A total of 20 target compounds were identified by ultra-high- performance liquid chromatography coupled with quadrupole time-of-flight tandem mass spectrometry. The main extraction parameters were optimized and included the ultrasonic power, ultrasonic time, sample pH, type of IL, the concentration of [C12mim]Br, extraction time, concentration of MCC, type of sorbent and type of elution solvents. Under the optimum conditions, the proposed method exhibited good linearities (r(2) ≥ 0.999) for all plant phenolic compounds with the lower limits of detection in the range of 0.21-0.41 ng/mL. The recoveries ranged from 82.74% to 97.88% for pinocembrin, chrysin and galangin. Compared with conventional solvent extraction, the present method was simpler and more efficient and required less organic solvent and a shorter extraction time. Finally, the methodology was successfully used for the extraction and enrichment of phenolic compounds in propolis. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Determination of Trichloroethylene in Water by Liquid–Liquid Microextraction Assisted Solid Phase Microextraction

    Directory of Open Access Journals (Sweden)

    Mengliang Zhang

    2015-02-01

    Full Text Available A method for the determination of trichloroethylene (TCE in water using portable gas chromatography/mass spectrometry (GC/MS was developed. A novel sample preparation method, liquid–liquid microextraction assisted solid phase microextraction (LLME–SPME, is introduced. In this method, 20 µL of hexane was added to 10 mL of TCE contaminated aqueous samples to assist headspace SPME. The extraction efficiency of SPME was significantly improved with the addition of minute amounts of organic solvents (i.e., 20 µL hexane. The absolute recoveries of TCE at different concentrations were increased from 11%–17% for the samples extracted by SPME to 29%–41% for the samples extracted by LLME–SPME. The method was demonstrated to be linear from 10 to 1000 ng mL−1 for TCE in water. The improvements on extraction efficiencies were also observed for toluene and 1, 2, 4-trichlorobenzene in water by using LLME–SPME method. The LLME–SPME method was optimized by using response surface modeling (RSM.

  3. 微滴液相微萃取技术用于气相色谱-质谱法分析药品中的酞酸酯和对羟基苯甲酸酯%Application of single drop microextraction in the determination of phthalate esters and parabens in drugs by gas chromatography-mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    漆爱明; 李玫瑰; 毛丽秋

    2008-01-01

    应用微滴液相微萃取(SDME)与气相色谱-离子阱质谱联用测定药品中的酞酸酯和对羟基苯甲酸酯.考察了萃取溶剂的种类及用量、微液滴在样品溶液中的深度、萃取时间及搅拌子的搅拌速度对微滴液相微萃取效果的影响.优化的萃取条件:萃取溶剂为1.5 μL甲苯,微液滴在样品溶液中的深度为0.8 cm,搅拌子的搅拌速度为 1 000 r/min,萃取时间为20 min.该方法的线性范围为0.032~80 mg/L,检出限为0.6 μg/L~1.28 mg/L,加标回收率为95.85% ~148.85% ,相对标准偏差为3.9% ~14.9% .

  4. Application of hollow fiber liquid phase microextraction and dispersive liquid–liquid microextraction techniques in analytical toxicology

    Directory of Open Access Journals (Sweden)

    Vahid Sharifi

    2016-04-01

    Full Text Available The recent developments in hollow fiber liquid phase microextraction and dispersive liquid–liquid microextraction are reviewed. Applications of these newly emerging developments in extraction and preconcentration of a vast category of compounds including heavy metals, pesticides, pharmaceuticals and abused drugs in complex matrices (environmental and biological matrices are reviewed and discussed. The new developments in these techniques including the use of solvents lighter than water, ionic liquids and supramolecular solvents are also considered. Applications of these new solvents reduce the use of toxic solvents and eliminate the centrifugation step, which reduces the extraction time.

  5. Solid-phase microextraction for the analysis of biological samples

    NARCIS (Netherlands)

    Theodoridis, G; Koster, EHM; de Jong, GJ

    2000-01-01

    Solid-phase microextraction (SPME) has been introduced for the extraction of organic compounds from environmental samples. This relatively new extraction technique has now also gained a lot of interest in a broad field of analysis including food, biological and pharmaceutical samples. SPME has a num

  6. Rapid pre-screening is more sensitive in liquid-based cytology than in conventional smears.

    Science.gov (United States)

    Dudding, Nick; Renshaw, Andrew A; Ellis, Kay

    2011-01-01

    Rapid pre-screening (RPS) is a useful tool to measure and improve performance in the cytology laboratory. Whether RPS is more or less effective in liquid-based cytology than in conventional smears is unknown. We compared the estimated sensitivity in a laboratory of 11 cytotechnologists which converted from conventional smears to SurePath™ (Becton Dickinson, Franklin Lakes, N.J., USA) liquid based cytology. In the 9 months prior to conversion, 23,286 smears were screened compared with 30,610 smears in the 12 months immediately after conversion. The estimated sensitivity of rapid pre-screening for 90 s improved significantly with liquid based cytology for all abnormalities (58.7 vs. 68.7%, pliquid-based cytology compared with conventional smears, and detects significant lesions that are missed by routine screening.

  7. Purification of Astaxanthin from Laminariajaponica by Ionic Liquid-based Monolithic Cartridge

    Institute of Scientific and Technical Information of China (English)

    YOON Chang-hwan; ZHU Tao; ROW Kyung-ho

    2012-01-01

    An effective and accurate method was developed for the extraction of astaxanthin from Laminariajaponica with subsequent separation by ionic liquid-based monolithic cartridge.The optimized extraction conditions including extraction solvent(ethanol),extraction time(90 min) and ultrasonic power(75 W) were obtained by systematical investigation.Chromatographic analysis was performed on a C18 column with ultraviolet(UV) detection at 476nm,and a solution consisting of methanol/acetonitrile/H20/dichloromethane(83:6:6:5,volume ratio) was used as the mobile phase at a flow rate of 0.7 mL/min.After ionic liquid-based monolithic solid phase extraction,17.82 μg/g astaxanthin was obtained from Laminariajaponica.This ionic liquid-based monolithic cartridge exhibits high affinity and selectivity for astaxanthin,and it can be potentially used as the stationary phase of high performance liquid chromatography( HPLC).

  8. Ionic liquid-based materials: a platform to design engineered CO2 separation membranes.

    Science.gov (United States)

    Tomé, Liliana C; Marrucho, Isabel M

    2016-05-21

    During the past decade, significant advances in ionic liquid-based materials for the development of CO2 separation membranes have been accomplished. This review presents a perspective on different strategies that use ionic liquid-based materials as a unique tuneable platform to design task-specific advanced materials for CO2 separation membranes. Based on compilation and analysis of the data hitherto reported, we provide a judicious assessment of the CO2 separation efficiency of different membranes, and highlight breakthroughs and key challenges in this field. In particular, configurations such as supported ionic liquid membranes, polymer/ionic liquid composite membranes, gelled ionic liquid membranes and poly(ionic liquid)-based membranes are detailed, discussed and evaluated in terms of their efficiency, which is attributed to their chemical and structural features. Finally, an integrated perspective on technology, economy and sustainability is provided.

  9. Comparison of Specimen Adequacy and Smear Quality in Conventional and Liquid-Based Pap Tests

    Directory of Open Access Journals (Sweden)

    Moradan

    2016-08-01

    Full Text Available Background Since the best method of cervical smear is a controversial subject, this study was designed to compare two methods of cervical sampling, consisting of conventional versus liquid base. Objectives Pap smear is a screening test used to detect pre malignant and malignant processes in the endocervical canal of the female reproductive system. There are two methods, consisting of conventional Pap, in which samples are smeared directly on a microscope slide after collection, and liquid based cytology, in which the smear sample is placed in a bottle of preservative for transport to the laboratory, where it is then smeared on the slide. In this study it was decided to compare these two methods of sampling. Methods This randomized trial was carried out at the Amir Hospital of Semnan, Iran on 240 females undergoing Pap smear screening from April to September 2012. Patients were divided to two groups including conventional (n = 120 and liquid base cytology smear (n = 120. The results of cytological reports of both groups were compared in regards to sufficiency of sample, presence of blood in the sample, presence of infection and premalignant or malignant condition. Results Specimen adequacy and smear quality were significantly better in liquid base sampling (P = 0.03; presence of benign cellular changes was not different between the two groups (P = 0.389. Diagnosis of bacterial vaginosis was significantly better with the conventional method (P = 0.007. Also, severe inflammation was more commonly reported in the conventional method than liquid base sampling test (P = 0.029. Conclusions Specimen adequacy and diagnosis of inflammatory reaction were better in liquid base smear and convention smear, respectively.

  10. Review of available scientific and technical evidence regarding liquid-based cytology

    Directory of Open Access Journals (Sweden)

    Alberto Frutos Pérez-Surio

    2017-06-01

    Full Text Available Introduction. Cervical cancer can be prevented by early diagnosis and treatment of patients with abnormal results, thus decreasing their incidence and mortality. In contrast to conventional techniques (Papanicolau, diagnostic techniques have been developed based on the preservation of the sample in a stabilizing solution (liquid-based cytology. The different methods of liquid-based cytology used in the screening of cervical cancer against the Papanicolau technique are evaluated. Material and methods. A systematic review of the literature has been performed (2010-2015. The search was developed by including MeSH terms as cervical intraepithelial neoplasia and papilloma virus infection in the MedLine, Embase, Cochrane Library, CRD, LILACS and IBECS databases. Inclusion criteria were adult women screened for cervical cancer using liquid-based cytology techniques, compared with conventional methods. Results. 464 references were found related to the reliability-precision of the test, of which 13 were included in the report. A health technology assessment report was conducted in 2013 by the Agency for Health Technology Assessment of Andalusia (AETSA. The quality of the studies was moderate and moderate-low. AETSA found studies that included more than 700,000 women between 14 and 90 years old, who were screened by liquid-based cytology, compared to the conventional one. Studies have shown that liquid-based cytology techniques reduce the percentage of unsatisfactory samples compared to conventional ones. The analysis of detection of cellular abnormalities and diagnostic validity indexes showed significant differences when comparing both methods. Conclusions. The studies analyzed presented methodological limitations. Hence, the results should be interpreted with caution. Liquid-based cytology did not present greater diagnostic capacity than conventional methods, but it reduced, with statistically significant results, the number of samples unsatisfactory

  11. Spectroscopic analysis of bosentan in biological samples after a liquid-liquid microextraction

    Directory of Open Access Journals (Sweden)

    Sanaz Sajedi-Amin

    2015-12-01

    Conclusion: A simple, low cost, precise and accurate spectrophotometric analysis of bosentan in biological samples after liquid-liquid microextraction were developed and validated for routine analyses.

  12. Solvent bar micro-extraction with graphite atomic absorption spectrometry for the determination of silver in ocean water.

    Science.gov (United States)

    López-López, José A; Herce-Sesa, Belén; Moreno, Carlos

    2016-10-01

    Main drawbacks for silver determination in seawater are the effects of samples matrix and that Ag appears in the sub ng L(-1). Available methods for sample preparation in Ag analysis are based on solid and liquid extraction using tedious process that increase the cost of analysis and the risk of sample contamination, producing important waste amounts. Solvent bar micro-extraction (SBME) allows the pre-concentration of Ag in a micro-volume of the ionic liquid Aliquat 336® in kerosene solution. For this reason, it is considered as a green alternative to standard methods. The method has been optimized using synthetic seawater samples, offering the highest response for samples at pH=2, using 5% Aliquat 336® dissolved in kerosene containing 5% dodecan-1-ol as acceptor solution and after 1h stirring at 800rpm. The method exhibited linearity up to 50ngL(-1), with a limit of detection of 0.09ngL(-1), covering the concentration range of interest for environmental studies. Finally, it was applied for determination of Ag in real seawater samples, and the results were compared with the reference method of liquid-liquid extraction with 1-pyrrolidine-dithiocarbamate and diethylammonium-diethyldithiocarbamate, showing the applicability of ionic liquid based SBME using Aliquat 336(®) for the simple monitoring of silver ultra-traces in seawater analysis.

  13. Novel routes to liquid-based self-healing polymer systems

    NARCIS (Netherlands)

    Mookhoek, S.D.

    2010-01-01

    Inspired by the current state-of-the-art and the progressing advancements in the field of self-healing materials, this thesis addresses several novel routes to advance the concept of liquid-based self-healing polymer systems. This thesis presents the concept and characterisation of a one-component s

  14. Diagnostic parameters in liquid-based cervical cytology using a coagulant suspension fixative

    NARCIS (Netherlands)

    Boon, ME; Ouwerkerk-Noordam, E; Suurmeijer, AH; Kok, LP

    2005-01-01

    Objective To evaluate in detail the morphology of cervical cell samples suspended in the coagulant fixative BoonFix (R) (Finetec, Tokyo, Japan) in liquid-based Papspin (R) slides (Thermo Shandon, Pittsburgh, Pennsylvania, U.S.A) to detect shifts in diagnostic parameters for infections and neoplasia.

  15. Novel routes to liquid-based self-healing polymer systems

    NARCIS (Netherlands)

    Mookhoek, S.D.

    2010-01-01

    Inspired by the current state-of-the-art and the progressing advancements in the field of self-healing materials, this thesis addresses several novel routes to advance the concept of liquid-based self-healing polymer systems. This thesis presents the concept and characterisation of a one-component

  16. Diagnostic parameters in liquid-based cervical cytology using a coagulant suspension fixative

    NARCIS (Netherlands)

    Boon, ME; Ouwerkerk-Noordam, E; Suurmeijer, AH; Kok, LP

    2005-01-01

    Objective To evaluate in detail the morphology of cervical cell samples suspended in the coagulant fixative BoonFix (R) (Finetec, Tokyo, Japan) in liquid-based Papspin (R) slides (Thermo Shandon, Pittsburgh, Pennsylvania, U.S.A) to detect shifts in diagnostic parameters for infections and neoplasia.

  17. Sulfonated polyvinyl chloride fibers for cation-exchange microextraction.

    Science.gov (United States)

    Xu, Li; Lee, Hian Kee

    2009-09-18

    Polyvinyl chloride (PVC) fiber was derivatized by concentrated sulfuric acid to yield sulfonated PVC (PVC-SO3H). The PVC-SO3H fiber had dual properties as a sorbent, based on cation-exchange and hydrophobicity. In the present study, the novel fiber was used directly as an individual device for extraction purposes in the cation-exchange microextraction of anaesthetics, followed by high-performance liquid chromatography-UV analysis. The results demonstrated that this PVC-SO3H fiber-based microextraction afforded convenient operation and cost-effective application to basic analytes. The limits of detection for four anaesthetics ranged from 1.2 to 6.0 ng/mL. No carryover (because of its disposable usage), and no loss of sorbent phase (which normally occurs in stir-bar sorptive extraction) during extraction were observed.

  18. Comparison of liquid-based cytology with conventional cytology for detection of cervical cancer precursors: a randomized controlled trial.

    NARCIS (Netherlands)

    Siebers, A.G.; Klinkhamer, P.J.; Grefte, J.M.M.; Massuger, L.F.A.G.; Vedder, J.E.; Beijers-Broos, A.; Bulten, J.; Arbyn, M.

    2009-01-01

    CONTEXT: Liquid-based cytology has been developed as an alternative for conventional cervical cytology. Despite numerous studies and systematic reviews, controversy remains about its diagnostic accuracy. OBJECTIVE: To assess the performance of liquid-based cytology compared with conventional cytolog

  19. Comparison of liquid-based cytology with conventional cytology for detection of cervical cancer precursors: a randomized controlled trial.

    NARCIS (Netherlands)

    Siebers, A.G.; Klinkhamer, P.J.; Grefte, J.M.M.; Massuger, L.F.A.G.; Vedder, J.E.; Beijers-Broos, A.; Bulten, J.; Arbyn, M.

    2009-01-01

    CONTEXT: Liquid-based cytology has been developed as an alternative for conventional cervical cytology. Despite numerous studies and systematic reviews, controversy remains about its diagnostic accuracy. OBJECTIVE: To assess the performance of liquid-based cytology compared with conventional cytolog

  20. Microextraction Methods for Preconcentration of Aluminium in Urine Samples

    Directory of Open Access Journals (Sweden)

    Farzad Farajbakhsh, Mohammad Amjadi, Jamshid Manzoori, Mohammad R. Ardalan, Abolghasem Jouyban

    2016-07-01

    Full Text Available Background: Analysis of aluminium (Al in urine samples is required in management of a number of diseases including patients with renal failure. This work aimed to present dispersive liquid-liquid microextraction (DLLME and ultrasound-assisted emulsification microextraction (USAEME methods for the preconcentration of ultra-trace amount of aluminum in human urine prior to its determination by a graphite furnace atomic absorption spectrometry (GFAAS. Methods: The microextraction methods were based on the complex formation of Al3+ with 8-hydroxyquinoline. The effect of various experimental parameters on the efficiencies of the methods and their optimum values were studied. Results: Under the optimal conditions, the limits of detection for USAEME-GFAAS and DLLME-GFAAS were 0.19 and 0.30 ng mL−1, respectively and corresponding relative standard deviations (RSD, n=5 for the determination of 40 ng mL−1 Al3+ were 5.9% and 4.9%. Conclusion: Both methods could be successfully used to the analysis of ultra trace concentrations of Al in urine samples of dialysis patients.

  1. Dynamic headspace time-extended helix liquid-phase microextraction.

    Science.gov (United States)

    Huang, Shih-Pin; Chen, Pai-Shan; Huang, Shang-Da

    2009-05-15

    Liquid-phase microextraction (LPME) has been proved to be a fast, inexpensive and effective sample pre-treatment technique for the analyses of pesticides and many other compounds. In this investigation, a new headspace microextraction technique, dynamic headspace time-extended helix liquid-phase microextraction (DHS-TEH-LPME), is presented. In this work, use of a solvent cooling system, permits the temperature of the extraction solvent to be lowered. Lowering the temperature of the extraction solvent not only reduces solvent loss but also extends the feasible extraction time, thereby improving extraction efficiency. Use of a larger volume of the solvent not only extends the feasible extraction time but also, after extraction, leaves a larger volume to be directly injected into the gas chromatography (GC) to increase extraction efficiency and instrument signal. The DHS-TEH-LPME technique was used to extract six organochlorine pesticides (OCPs) from 110ml water samples that had been spiked with the analytes at ng/l levels, and stirred for 60min. The proposed method attained enrichments up to 2121 fold. The effects of extraction solvent identity, sample agitation, extraction time, extraction temperature, and salt concentration on extraction performance were also investigated. The method detection limits (MDLs) varied from 0.2 to 25ng/l. The calibration curves were linear for at least 2 orders of magnitude with R(2)>==0.996. Relative recoveries in river water were more than 86%.

  2. Experimental and Numerical Investigations of Single Drop Mass Transfer in Solvent Extraction Systems with Resistance in Both Phases%萃取体系滴内和两相阻力控制的单液滴传质实验和数值模拟研究

    Institute of Scientific and Technical Information of China (English)

    李天文; 毛在砂; 陈家镛; 费维扬

    2002-01-01

    Numerical simulation of transient mass transfer to a single drop controlled by the internal resistance or by the resistance in both phases was mathematically formulated and simulated in a boundary-fitted orthogonal coordinate system. The simulated results on the transient mass transfer dominated by the internal resistance are in good agreement with the Newman and Kronig-Brink models for drops with low Reynolds number. When the drop Reynolds number is up to 200, the mass transfer coefficient from numerical simulation is very low as compared with the Handlos-Baron model. The cases with mass transfer resistance residing in both the continuous and drop phases were simulated successfully and compared with the experimental data in three extraction systems recommended by European Confederation of Chemical Engineering (EFCE). For single drops with Re < 200, the numerically predicted values of the extraction fraction and overall mass transfer coefficient are in reasonable coincidence with the experimental data. It is concluded that the numerical simulation can be resorted in some cases of solvent extraction for conducting numerical experiments and parametric study. Nevertheless, for better resolution as higher Reynolds number drops are simulated, more sophisticated techniques should be developed and incorporated to deal with the large deformation and transient shape oscillation as well as possible Marangoni effect.

  3. Peculiar surface behavior of some ionic liquids based on active pharmaceutical ingredients.

    Science.gov (United States)

    Restolho, José; Mata, José Luis; Saramago, Benilde

    2011-02-21

    The ionic liquids based on biologically active cations and anions, commonly designated by ionic liquids based on active pharmaceutical ingredients (ILs-APIs), are interesting compounds for use in pharmaceutical applications. Lidocaine docusate, ranitidine docusate, and didecyldimethylammonium ibuprofen are examples of promising ILs-APIs that were recently synthesized. They were submitted to biological testing and calorimetric measurements, but nothing is known about their surface properties. In this work, we measured the surface tension and the contact angles on both hydrophilic and hydrophobic surfaces in a temperature range as wide as possible. Based on the wettability data, the polarity fractions were estimated using the Fowkes theory. The peculiar surface behavior observed was tentatively attributed to the presence of mesophases.

  4. Role of Liquid-based Cytology and Cell Block in the Diagnosis of Endometrial Lesions

    OpenAIRE

    Hui Zhang; Jia Wen; Pi-Li Xu; Rui Chen; Xi Yang; Lian-Er Zhou; Ping Jiang; An-Xia Wan; Qin-Ping Liao

    2016-01-01

    Background: Liquid-based cytology (LBC) offers an alternative method to biopsy in screening endometrial cancer. Cell block (CB), prepared by collecting residual cytological specimen, represents a novel method to supplement the diagnosis of endometrial cytology. This study aimed to compare the specimen adequacy and diagnostic accuracy of LBC and CB in the diagnosis of endometrial lesions. Methods: A total of 198 women with high risks of endometrial carcinoma (EC) from May 2014 to April 2015...

  5. Development of a new green non-dispersive ionic liquid microextraction method in a narrow glass column for determination of cadmium prior to couple with graphite furnace atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Naeemullah, E-mail: naeemullah433@yahoo.com [Gaziosmanpaşa University, Faculty of Science and Arts, Chemistry Department, 60250 Tokat (Turkey); National Centre of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080 (Pakistan); Kazi, Tasneem Gul [National Centre of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080 (Pakistan); Tuzen, Mustafa [Gaziosmanpaşa University, Faculty of Science and Arts, Chemistry Department, 60250 Tokat (Turkey); Shah, Faheem; Afridi, Hassan Imran [National Centre of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080 (Pakistan); Citak, Demirhan [Gaziosmanpaşa University, Faculty of Science and Arts, Chemistry Department, 60250 Tokat (Turkey)

    2014-02-17

    Graphical abstract: -- Highlights: •A novel and rapid non-dispersive ionic liquid based microextractions. •We used a long narrow glass column to provide more contact area between two media (aqueous and extractive). •APDC using as complexing agent and analyzed by GFAAS. •Introduced a novel approach that reduced solvent consumption, effort, time. •It was applied for determination of understudy analytes in real water sample. -- Abstract: Easy and innovative non-dispersive ionic liquid based microextraction (NDILME) has been developed for preconcentration of trace level of cadmium (Cd) in aqueous real surface water samples prior to couple with graphite furnace atomic absorption spectrometry (GFAAS). A 200 cm long narrow glass column containing aqueous solution of standard/sample was used to increase phase transfer ratio by providing more contact area between two medium (aqueous and extractive), which drastically improve the recoveries of labile hydrophobic chelate of Cd ammonium pyrrolidinedithiocarbamate (APDC), into ionic liquid 1-butyl-3-methylimidazolium hexafluorophosphate [C{sub 4}mim][PF{sub 6}]. Different aspect of the desire method have been investigated and optimized. Under the optimized key experimental variables, limit of detection (LOD) and enhancement factor (EF) were achieved to be 0.5 ng L{sup −1} and 150, respectively. Reliability of the model method was checked by relative standard deviation (%RSD), which was found to be < 5%. Validity and accuracy of the developed method was checked by analysis of certified reference water samples (SLRS-4 Riverine water) using standard addition method. Application of the model method was productively performed by analysis of Cd in real surface water samples (tap and sea)

  6. Design of guanidinium ionic liquid based microwave-assisted extraction for the efficient extraction of Praeruptorin A from Radix peucedani.

    Science.gov (United States)

    Ding, Xueqin; Li, Li; Wang, Yuzhi; Chen, Jing; Huang, Yanhua; Xu, Kaijia

    2014-12-01

    A series of novel tetramethylguanidinium ionic liquids and hexaalkylguanidinium ionic liquids have been synthesized based on 1,1,3,3-tetramethylguanidine. The structures of the ionic liquids were confirmed by (1)H NMR spectroscopy and mass spectrometry. A green guanidinium ionic liquid based microwave-assisted extraction method has been developed with these guanidinium ionic liquids for the effective extraction of Praeruptorin A from Radix peucedani. After extraction, reversed-phase high-performance liquid chromatography with UV detection was employed for the analysis of Praeruptorin A. Several significant operating parameters were systematically optimized by single-factor and L9 (3(4)) orthogonal array experiments. The amount of Praeruptorin A extracted by [1,1,3,3-tetramethylguanidine]CH2CH(OH)COOH is the highest, reaching 11.05 ± 0.13 mg/g. Guanidinium ionic liquid based microwave-assisted extraction presents unique advantages in Praeruptorin A extraction compared with guanidinium ionic liquid based maceration extraction, guanidinium ionic liquid based heat reflux extraction and guanidinium ionic liquid based ultrasound-assisted extraction. The precision, stability, and repeatability of the process were investigated. The mechanisms of guanidinium ionic liquid based microwave-assisted extraction were researched by scanning electron microscopy and IR spectroscopy. All the results show that guanidinium ionic liquid based microwave-assisted extraction has a huge potential in the extraction of bioactive compounds from complex samples.

  7. Development and optimization of a naphthoic acid-based ionic liquid as a "non-organic solvent microextraction" for the determination of tetracycline antibiotics in milk and chicken eggs.

    Science.gov (United States)

    Gao, Jiajia; Wang, Hui; Qu, Jingang; Wang, Huili; Wang, Xuedong

    2017-01-15

    In traditional ionic liquids (ILs)-based microextraction, ILs are often used as extraction and dispersive solvents; however, their functional effects are not fully utilized. Herein, we developed a novel ionic liquid 1-butyl-3-methylimidazolium naphthoic acid salt ([C4MIM][NPA]) with strong acidity. It was used as a mixed dispersive solvent with conventional [C2MIM][BF4] in "functionalized ionic liquid-based non-organic solvent microextraction (FIL-NOSM)" for determination of tetracycline antibiotics (TCs) in milk and eggs. Utilization of [C4MIM][NPA] in FIL-NOSM method increased extraction recoveries (ERs) of TCs by more than 20% and eliminated the pH adjustment step because of its strong acidity. Under optimized conditions based on central composite design, the ERs of four TCs were 94.1-102.1%, and the limitsofdetection were 0.08-1.12μgkg(-1) in milk and egg samples. This proposed method provides high extraction efficiency, less pretreatment time and requires non-organic solvents for determination of trace TC concentrations in complex animal-based food matrices.

  8. Determination of steroid hormones in biological and environmental samples using green microextraction techniques: an overview.

    Science.gov (United States)

    Aufartová, Jana; Mahugo-Santana, Cristina; Sosa-Ferrera, Zoraida; Santana-Rodríguez, José Juan; Nováková, Lucie; Solich, Petr

    2011-10-17

    Residues of steroid hormones have become a cause for concern because they can affect the biological activity of non-target organisms. Steroid hormones are a potential risk for wildlife and humans through the consumption of contaminated food or water. Their determination requires extraction and clean-up steps, prior to detection, to reach low concentration levels. In recent years, a great effort has been made to develop new analytical methodologies, such as microextraction techniques, that reduce environmental pollution. Researchers have modified old methods to incorporate procedures that use less-hazardous chemicals or that use smaller amounts of them. They are able to do direct analysis using miniaturised equipment and reduced amounts of solvents and wastes. These accomplishments are the main objectives of green analytical chemistry. In this overview, we focus on microextraction techniques for the determination of steroid hormones in biological (e.g., human urine, human serum, fish, shrimp and prawn tissue and milk) and environmental (e.g., wastewaters, surface waters, tap waters, river waters, sewage sludges, marine sediments and river sediments) samples. We comment on the most recent applications in sorptive-microextraction modes, such as solid phase microextraction (SPME) with molecularly imprinted polymers (MIPs), in-tube solid-phase microextraction (IT-SPME), stir-bar sorptive extraction (SBSE) and microextraction in packed sorbent (MEPS). We also describe liquid-phase microextraction (LPME) approaches reported in the literature that are applied to the determination of steroid hormones.

  9. Testing automated liquid-based cytology samples with a manual liquid-based cytology method using residual cell suspensions from 500 ThinPrep cases.

    Science.gov (United States)

    Maksem, John A; Dhanwada, Vijaya; Trueblood, Joy E; Weidmann, James; Kane, Bruce; Bolick, David R; Bedrossian, Carlos W M; Kurtycz, Daniel F I; Stewart, Jim

    2006-06-01

    We report a technical improvement upon a previously disclosed manual liquid-based cytology (MLBC) method; and, we use the improved method to prepare slides from residual ThinPrep specimens in order to see how often ThinPrep diagnoses correspond to diagnoses derived from exhaustive examination of their parent sample suspensions. Residual cell suspensions from 500 ThinPrep cases comprising (1) 20 low-grade squamous intraepithelial lesions (LSILs); (2) 200 high risk (HR) negatives and 20 ASC-US; and (3) 260 screening cytology specimens were studied. Institutional review committee guidelines allowed us to know diagnoses by groups of specimens, but did not allow us to know individual patient diagnoses, so we could not perform case-by-case matched outcome-comparisons. Cells were concentrated by conventional centrifugation and sedimented into a polymer gel that was then vortex-mixed and converted into a viscous cell-rich suspension. The cell suspension was smeared between two clean glass slides, which were air-dried and stained with the Papanicolaou stain. Two study-sets were created, comprising one slide from each case. Each of the two study sets was examined by two cytopathologists, and discordant diagnoses were adjudicated. Because of the ambiguity involved in the "atypical" (ASC-US, ASC-H, AGC) diagnosis categories, only outcomes at the level of LSIL or greater were recorded. All MLBC SILs were digitally imaged and abnormal slides plus digital images were sent to the laboratory that provided the residual automated liquid-based cytology (ALBC) suspensions. The final diagnoses were confirmed by the laboratory that provided the residual ALBC specimens. MLBC slides of the 20 LSIL cases afforded 2 high-grade squamous intraepithelial lesions (HSILs) and 18 LSILs. Those of the 200 HR-Negatives showed 3 HSILs and 30 LSILs; and those of the 20 HR-ASC-US showed 3 HSILs and 9 LSILs. MLBC slides of the 260 screening cytology specimens showed 1 Carcinoma, 3 HSILs and 20 LSILs

  10. A novel ionic liquids-based scrubbing process for efficient CO2 capture

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    A novel alkanolamine-based ionic liquid,N-methyl-diethanolammonium tetrafluoroborate ([MDEA][BF4]),was synthesized in our laboratory.The ionic liquid-based composite solution consisting of N-methyl-diethanolamine (MDEA),[MDEA][BF4],piperazine (PZ) and H2O was investigated for CO2 capture.The optimal performance for CO2 capture was found at 45°C,1.50 MPa,probably due to a synergistic action of the reaction and the transport.No apparent corrosion was found on stainless and carbon steel with the above composite solution.This finding is very significant to the promotion of its engineering application.

  11. Makorin Ring Finger Protein 1 as Adjunctive Marker in Liquid-based Cervical Cytology.

    Science.gov (United States)

    Lee, Maria; Chang, Min Young; Shin, Ha-Yeon; Shin, Eunah; Hong, Sun Won; Kim, Kyung-Mi; Chay, Doo Byung; Cho, Hanbyoul; Kim, Jae-Hoon

    2016-01-01

    To assess the utility of makorin ring finger protein 1 (MKRN1) as a marker of cervical pathology.A PROspective specimen collection and retrospective Blinded Evaluation study was conducted. Liquid-based cytology samples were collected from 187 women, embedding all residuals as cell blocks for immunohistochemical staining of MKRN1 and P16 . Results of liquid-based cervical cytology, immunostained cell block sections, and human papillomavirus (HPV) hybrid capture (with real-time polymerase chain reaction) were analyzed. Clinical outcomes were analyzed overall and in subsets of specimens yielding atypical squamous cells of undetermined significance or low-grade squamous intraepithelial lesions.Makorin ring finger protein 1 positivity and grades (1-3) of cervical intraepithelial neoplasia (CIN) increased in tandem (CIN1, 32.4%; CIN2, 60.0%; and CIN3, 80.0%), reaching 92.3% in invasive cancer. Sensitivity, specificity, positive predictive value, and negative predictive value in detecting CIN2+ via MKRN1 were 73.8%, 76.8%, 75.6%, and 75.0%, respectively. The performance of liquid-based cytology was poorer by comparison (61.3%, 69.5%, 66.2%, and 64.8%, respectively), and HPV assay (versus MKRN1 immunohistochemical staining) displayed lower specificity (67.7%). Combined HPV + MKRN1 testing proved highest in sensitivity, specificity, positive predictive value, and negative predictive value (71.8%, 85.5%, 82.3%, and 76.5%, respectively), whereas corresponding values for cytology + HPV (60.6%, 81.8%, 75.4%, and 69.2%) and cytology + MKRN1 (58.8%, 84.1%, 78.3%, and 67.7%) were all similar. In instances of atypical squamous cells of undetermined significance or low-grade squamous intraepithelial lesions, the HPV + MKRN1 combination performed best by above measures (100%, 72.7%, 73.9%, and 100%), followed by cytology + MKRN1 (100%, 50.0%, 60.7%, and 100%).Makorin ring finger protein 1 displayed greater sensitivity and specificity than liquid-based cytology and

  12. Case Report: Liquid-based cytology aids in primary fallopian tube cancer diagnosis

    Institute of Scientific and Technical Information of China (English)

    Zhuo REN; Yun-ping ZHANG; Hui-xia YANG; Li-rong ZHU

    2009-01-01

    Primary fallopian tube carcinoma (PFTC) is a rare malignant carcinoma among all genital tract malignancies. It occurs most commonly in postmenopausal women and is similar to ovarian malignancy historically and clinically. Because of its insidious onset and silent course, the diagnosis is made usually postoperatively. Liquid-based cytology (LBC) is a type of method for cervical cancer screening, but sometimes it may aid in making PFTC diagnosis. We report a 47-year-old woman with PFTC, whose diagnosis was made with the aid of LBC.

  13. Combination of dispersive liquid-liquid microextraction and solid-phase microextraction: An efficient hyphenated sample preparation method.

    Science.gov (United States)

    Jafari, Mohammad T; Saraji, Mohammad; Mossaddegh, Mehdi

    2016-09-30

    Two well-known microextraction methods, dispersive liquid-liquid microextraction (DLLME) and solid-phase microextraction (SPME), were combined, resulting in as an encouraging method. The method, named DLLME-SPME, was performed based on total vaporization technique. For the DLLME step, 1,1,2,2-tetrachloroethane and acetonitrile were used as extraction and disperser solvents, respectively. Halloysite nanotubes-titanium dioxide was used as the fiber coating in the SPME step. The method was applied for the extraction of diazinon and parathion (as the test compounds) in environmental water samples and fruit juices, and gas chromatography-corona discharge ion mobility spectrometry was used as the determination apparatus. Desorption temperature and time, extraction temperature and time, and the volume of the extracting solvent in the DLLME step were optimized as the effective parameters on the extraction efficiency. The relative standard deviations (RSDs) of intra-day were found to be 4-7% and 6-8% for diazinon and parathion, respectively. Also, the RSDs of inter-day were 7-9% and 8-10% for diazinon and parathion, respectively. The limits of quantification and detection were obtained to be 0.015 and 0.005μgL(-1) for diazinon, and 0.020 and 0.007μgL(-1) for parathion. A good linearity range (r(2)˃0.993) was obtained in the range of 0.015-3.000 and 0.020-3.000μgL(-1) for diazinon and parathion, respectively. The high enrichment factors were obtained as 3150 and 2965 for diazinon and parathion, respectively. This method showed high sensitivity with good recovery values (between 87 and 99%) for the extraction of target analytes in the real samples. Overall, the results revealed that the developed DLLME-SPME method had better extraction efficiency than DLLME and SPME alone.

  14. Surface nanodroplets for highly efficient liquid-liquid microextraction

    Science.gov (United States)

    Li, Miaosi; Lu, Ziyang; Yu, Haitao; Zhang, Xuehua

    2016-11-01

    Nanoscale droplets on a substrate are an essential element for a wide range of applications, such as laboratory-on-chip devices, simple and highly efficient miniaturized reactors for concentrating products, high-throughput single-bacteria or single-biomolecular analysis, encapsulation, and high-resolution imaging techniques. The solvent exchange process is a simple bottom-up approach for producing droplets at solid-liquid interfaces that are only several tens to hundreds of nanometers in height, or a few femtoliters in volume Oil nanodroplets can be produced on a substrate by solvent exchange in which a good solvent of oil is displaced by a poor solvent. Our previous work has significantly advanced understanding of the principle of solvent exchange, and the droplet size can be well-controlled by several parameters, including flow rates, flow geometry, gravitational effect and composition of solutions. In this work, we studied the microextraction effect of surface nanodroplets. Oil nanodroplets have been demonstrated to provide highly-efficient liquid-liquid microextraction of hydrophobic solute in a highly diluted solution. This effect proved the feasibility of nanodroplets as a platform for preconcentrating compounds for in situ highly sensitive microanalysis without further separation. Also the long lifetime and temporal stability of surface nanodroplets allow for some long-term extraction process and extraction without addition of stabilisers.

  15. Ultrasound-assisted emulsification microextraction for the determination of ephedrines in human urine by capillary electrophoresis with direct injection. Comparison with dispersive liquid-liquid microextraction.

    Science.gov (United States)

    Alshana, Usama; Göğer, Nilgün G; Ertaş, Nusret

    2012-08-01

    Ultrasound-assisted emulsification microextraction and dispersive liquid-liquid microextraction were compared for extraction of ephedrine, norephedrine, and pseudoephedrine from human urine samples prior to their determination by capillary electrophoresis. Formation of a microemulsion of the organic extract with an aqueous solution (at pH 3.2) containing 10% methanol facilitated the direct injection of the final extract into the capillary. Influential parameters affecting extraction efficiency were systematically studied and optimized. In order to enhance the sensitivity further, field-amplified sample injection was applied. Under optimum extraction and stacking conditions, enrichment factors of up to 140 and 1750 as compared to conventional capillary zone electrophoresis were obtained resulting in limits of detection of 12-33 μg/L and 1.0-2.8 μg/L with dispersive liquid-liquid microextraction and ultrasound-assisted emulsification microextraction when combined with field-amplified sample injection. Calibration graphs showed good linearity for urine samples by both methods with coefficients of determination higher than 0.9973 and percent relative standard deviations of the analyses in the range of 3.4-8.2% for (n = 5). The results showed that the use of ultrasound to assist microextraction provided higher extraction efficiencies than disperser solvents, regarding the hydrophilic nature of the investigated analytes.

  16. Microextraction techniques in the analysis of food flavor compounds: A review.

    Science.gov (United States)

    Jeleń, Henryk H; Majcher, Małgorzata; Dziadas, Mariusz

    2012-08-13

    Food flavor compounds due to the complexity of food as a matrix, and usually their very low concentrations in a product, as well as their low odor thresholds, create a challenge in their extraction, separation and quantitation. Food flavor volatiles represent compounds of different polarity, volatility and chemical character, which determine method of extraction for their isolation from food. Microextraction techniques, mainly SPME and SBSE have been used for food flavor compounds analysis for two decades. Microextraction methods other than SPME and SBSE are seldom used despite their analytical potential. The review discusses the nature of food flavor compounds, and different approaches to food flavor analysis. It summarizes the use of microextraction methods in food flavor compounds analysis based on papers published in the last 5years, and discusses the potential of microextraction methods in this field. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. Kinetic aspects of hollow fiber liquid-phase microextraction and electromembrane extraction

    DEFF Research Database (Denmark)

    Gjelstad, Astrid; Jensen, Henrik; Rasmussen, Knut Einar

    2012-01-01

    In this paper, extraction kinetics was investigated experimentally and theoretically in hollow fiber liquid-phase microextraction (HF-LPME) and electromembrane extraction (EME) with the basic drugs droperidol, haloperidol, nortriptyline, clomipramine, and clemastine as model analytes. In HF...

  18. Highly Stretchable, Hysteresis-Free Ionic Liquid-Based Strain Sensor for Precise Human Motion Monitoring.

    Science.gov (United States)

    Choi, Dong Yun; Kim, Min Hyeong; Oh, Yong Suk; Jung, Soo-Ho; Jung, Jae Hee; Sung, Hyung Jin; Lee, Hyung Woo; Lee, Hye Moon

    2017-01-18

    A highly stretchable, low-cost strain sensor was successfully prepared using an extremely cost-effective ionic liquid of ethylene glycol/sodium chloride. The hysteresis performance of the ionic-liquid-based sensor was able to be improved by introducing a wavy-shaped fluidic channel diminishing the hysteresis by the viscoelastic relaxation of elastomers. From the simulations on visco-hyperelastic behavior of the elastomeric channel, we demonstrated that the wavy structure can offer lower energy dissipation compared to a flat structure under a given deformation. The resistance response of the ionic-liquid-based wavy (ILBW) sensor was fairly deterministic with no hysteresis, and it was well-matched to the theoretically estimated curves. The ILBW sensors exhibited a low degree of hysteresis (0.15% at 250%), low overshoot (1.7% at 150% strain), and outstanding durability (3000 cycles at 300% strain). The ILBW sensor has excellent potential for use in precise and quantitative strain detections in various areas, such as human motion monitoring, healthcare, virtual reality, and smart clothes.

  19. Highly Flexible Graphene Oxide Nanosuspension Liquid-Based Microfluidic Tactile Sensor.

    Science.gov (United States)

    Kenry; Yeo, Joo Chuan; Yu, Jiahao; Shang, Menglin; Loh, Kian Ping; Lim, Chwee Teck

    2016-03-23

    A novel graphene oxide (GO) nanosuspension liquid-based microfluidic tactile sensor is developed. It comprises a UV ozone-bonded Ecoflex-polydimethylsiloxane microfluidic assembly filled with GO nanosuspension, which serves as the working fluid of the tactile sensor. This device is highly flexible and able to withstand numerous modes of deformation as well as distinguish various user-applied mechanical forces it is subjected to, including pressing, stretching, and bending. This tactile sensor is also highly deformable and wearable, and capable of recognizing and differentiating distinct hand muscle-induced motions, such as finger flexing and fist clenching. Moreover, subtle differences in the handgrip strength derived from the first clenching gesture can be identified based on the electrical response of our device. This work highlights the potential application of the GO nanosuspension liquid-based flexible microfluidic tactile sensing platform as a wearable diagnostic and prognostic device for real-time health monitoring. Also importantly, this work can further facilitate the exploration and potential realization of a functional liquid-state device technology with superior mechanical flexibility and conformability.

  20. Economic evaluation of DNA ploidy analysis vs liquid-based cytology for cervical screening.

    Science.gov (United States)

    Nghiem, V T; Davies, K R; Beck, J R; Follen, M; MacAulay, C; Guillaud, M; Cantor, S B

    2015-06-09

    DNA ploidy analysis involves automated quantification of chromosomal aneuploidy, a potential marker of progression toward cervical carcinoma. We evaluated the cost-effectiveness of this method for cervical screening, comparing five ploidy strategies (using different numbers of aneuploid cells as cut points) with liquid-based Papanicolaou smear and no screening. A state-transition Markov model simulated the natural history of HPV infection and possible progression into cervical neoplasia in a cohort of 12-year-old females. The analysis evaluated cost in 2012 US$ and effectiveness in quality-adjusted life-years (QALYs) from a health-system perspective throughout a lifetime horizon in the US setting. We calculated incremental cost-effectiveness ratios (ICERs) to determine the best strategy. The robustness of optimal choices was examined in deterministic and probabilistic sensitivity analyses. In the base-case analysis, the ploidy 4 cell strategy was cost-effective, yielding an increase of 0.032 QALY and an ICER of $18 264/QALY compared to no screening. For most scenarios in the deterministic sensitivity analysis, the ploidy 4 cell strategy was the only cost-effective strategy. Cost-effectiveness acceptability curves showed that this strategy was more likely to be cost-effective than the Papanicolaou smear. Compared to the liquid-based Papanicolaou smear, screening with a DNA ploidy strategy appeared less costly and comparably effective.

  1. Morphometric analysis of endometrial cells in liquid-based cervical cytology samples.

    Science.gov (United States)

    Gupta, P; Gupta, N; Dey, P

    2017-04-01

    Exfoliated endometrial cells can be seen in cervical smears in association with a wide variety of conditions ranging from normal proliferative endometrium to endometrial malignancies. It is often difficult to differentiate between benign, atypical and malignant endometrial cells using cytomorphology alone. This study was conducted to evaluate if morphometric analysis of endometrial nuclei on liquid-based cervical samples could be of help in differentiating between these endometrial cells. Three groups of cervical samples with histopathological correlation were selected: Group A: showing benign endometrial cells; Group B: showing atypical endometrial cells and Group C: showing malignant endometrial cells. There were 30 cases each in Group A and B and 39 cases in Group C. Image J, NIH, USA was used for selecting the endometrial nuclei and performing the morphometric measurements. MANOVA was used for statistical analysis. The mean nuclear area and nuclear perimeter were significantly different between the three groups of endometrial cells with a P-value liquid-based cervical cytology samples. © 2016 John Wiley & Sons Ltd.

  2. Non-computer-assisted liquid-based cytology for diagnosis of oral squamous cell carcinoma.

    Science.gov (United States)

    Pérez-Sayáns, M; Reboiras-López, M D; Gayoso-Diz, P; Seijas-Naya, F; Antúnez-López, J R; Gándara-Rey, J M; García-García, A

    2012-01-01

    The development of oral squamous cell carcinoma (OSCC) occasionally follows the neoplastic progression of other premalignant lesions. Although biopsy is the definitive diagnostic method, liquid-based cytology is an adequate method for screening suspicious lesions. We compared liquid-based cytology to histology for diagnosis of OSCC in patients with oral lesions that raised clinical suspicion of malignancy. Our sample consisted of 48 patients. Cytological samples were obtained by scraping the lesion superficially using Cytobrush®. We conducted cytological and histopathological evaluation of all preparations. We estimated sensitivity and specificity levels as well as positive and negative predictive values. The degree of inter-observer agreement for both methods was assessed using the kappa index. Twenty-eight (58.3%) of the cases finally were diagnosed with OSCC and 20 (41.7%) were determined to be premalignant lesions. We observed eight false negatives and no false positives; OSCC prevalence was 56.5%. The values for diagnostic indices were: sensitivity, 69% (CI 95%, prevalence 51.87); specificity, 100%; positive predictive value, 100%; negative predictive value, 71% (CI 95% 54.82). A kappa index of 0.622 (CI 95% 0.93, 0.39) was observed.

  3. Vortex-assisted ionic liquid microextraction coupled to flame atomic absorption spectrometry for determination of trace levels of cadmium in real samples

    Directory of Open Access Journals (Sweden)

    Mahmoud Chamsaz

    2013-01-01

    Full Text Available A simple and rapid vortex assisted ionic liquid based liquid–liquid microextraction technique (VALLME was proposed for preconcentration of trace levels of cadmium. According to this method, the extraction solvent was dispersed into the aqueous samples by the assistance of vortex agitator. Cadmium preconcentration was mediated by chelation with the 8-hydroxyquinoline (oxine reagent and an IL, 1-octyl-3-methylimidazolium hexafluorophosphate ([Omim][PF6] was chosen as the extraction solvent to extract the hydrophobic complex. Several variables such as sample pH, concentration of oxine, volume of [Omim][PF6] and extraction time were investigated in details and optimum conditions were selected. Under the optimum conditions, the limit of detection (LOD was 2.9 μg L−1 for Cd (ІІ and relative standard deviation (RSD% for five replicate determinations of 125 μg L−1 was 4.1%. The method was successfully applied to the determination of cadmium in tap water, apple and rice samples.

  4. CLINICAL ASSESSMENT AND CORRILATION OF PAP SMEAR AND LIQUID BASED CYTOLOGY IN BAD CERVIX

    Directory of Open Access Journals (Sweden)

    Khushboo

    2014-10-01

    Full Text Available AIM: Aim of our study to analyze the prevalence of premalignant lesion based on Pap smear and liquid based cytology in patients of bad cervix. OBJECTIVE: To compare sensitivity and specificity of two methods for screening of bad cervix and to know IDR (increase detection rate of cervical cancer by conventional Pap smear and liquid based cytology. MATERIAL AND METHOD: 200 women attending Gynaecology OPD were random selection on the basis of inclusion criteria. All 200 selected women were subjected for down staging through per speculum examination for identification of bad cervix. Pap smears of all 200 selected women were taken and ensured that no local douche, antiseptic cream and no local internal examination was done on the day of test. The prepared smears were then stained according to Papanicolaou's technique. Liquid based cytology smears preparing by using cervical brush 1-1.5cm were inserted into the cervical os until the large outer bristles of the brush touch ectocervix. Data collected for sociodemographic, parity, down staging clinical examination Pap smear and LBC was organised, interpreted and analysis on appropriate statistical software. P value < 0.05 is considered significant RESULT: Analysis revealed that the maximum number of women in our study are from middle age group(31-40yrs, low socioeconomic status, married before 18 yrs, multipara, do not use any contraceptive, uneducated, urban, Muslim population.in this study more abnormal smear is seen in LBC as compared to pap smear. Sensitivity and specificity for LBC is more as compare to pap smear. CONCLUSION: In low resource setting like ours were facilities for radiology, chemo- radiotherapy and supportive care are limited or unavailable. It is important to identify which resources fill healthcare need most effectively and to consider alternative approaches, LBC is strongly advocated in the best interest of public health, by improving the quality of the sample and reducing the

  5. Comparative study of the results from conventional cervico-vaginal oncotic cytology and liquid-based cytology.

    Science.gov (United States)

    Stabile, Sueli Aparecida Batista; Evangelista, Dilson Henrique Ramos; Talamonte, Valdely Helena; Lippi, Umberto Gazi; Lopes, Reginaldo Guedes Coelho

    2012-01-01

    To compare two oncotic cervical cytology techniques, the conventional and the liquid-based cytology, in low risk patients for uterine cervical cancer. Comparative prospective study with 100 patients who came to their annual gynecological exam, and were submitted simultaneously to both techniques. We used the McNemar test, with a significance level of p cytology and in 84% of the liquid-based cytology had statistical significance. As for the diagnosis of atypical cells they were detected in 3% of conventional cytology and in 10% of liquid-based cytology (p = 0.06). Atypical squamous cells of undetermined significance were the most prevalent abnormality. The liquid-based cytology performance was better when compared with colposcopy (guided biopsy), presenting sensitivity of 66.7% and specificity of 100%. There was no cytological and histological concordance for the conventional cytology. Liquid-based cytology had a better performance to diagnose atypical cells and the cytohistological concordance was higher than in the conventional cytology.

  6. Histological Correlation of Glandular Abnormalities in Cervical Liquid-Based Cytology

    Directory of Open Access Journals (Sweden)

    Yosuke Kawakami

    2011-01-01

    Full Text Available Conventional Papanicolaou smear method is still commonly used for cervical cancer screening in Japan, despite the liquid-based cytology (LBC that has become a global tendency in the world recently. One of the obstacles in the way of popularization of this method seems to be the confusion as to diagnosis upon cervical glandular lesions. We performed comparison study between LBC and conventional Papanicolaou smear about cytological diagnosis using split-sample method in 4522 patients. In 13 cases analyses, which were reported with either AGC or adenocarcinoma by either method, LBC tends to be milder than that by conventional smear, however, the credibility of LBC is considered to be near to that of conventional smear with regard to screening for glandular abnormalities. These results indicate that cervical cancer screening should shift to LBC under the enough experience and appropriate dealing with the cytological diagnosis.

  7. Repeating cytological preparations on liquid-based cytology samples: A methodological advantage?

    Science.gov (United States)

    Pinto, Alvaro P; Maia, Henrique Felde; di Loretto, Celso; Krunn, Patrícia; Túlio, Siumara; Collaço, Luis Martins

    2007-10-01

    This study investigates the rule that repeating cytological preparations on liquid-based cytology improves sample adequacy, diagnosis, microbiological, and hormonal evaluations. We reviewed 156 cases of pap-stained preparations of exfoliated cervical cells in two slides processed by DNA-Cytoliq System. After sample repeat/dilution, limiting factors affecting sample adequacy were removed in nine cases and three unsatisfactory cases were reclassified as satisfactory. Diagnosis was altered in 24 cases. Of these, the original diagnosis in 15 was atypical squamous cells of undetermined significance; after the second slide examination, diagnosis in 5 of the 15 cases changed to low-grade squamous intraepithelial lesion, 3 to high-grade squamous intraepithelial lesion, and 7 to absence of lesion. Microbiological evaluation was altered, with Candida sp. detected in two repeated slides. Repeat slide preparation or dilution of residual samples enhances cytological diagnosis and decreases effects of limiting factors in manually processed DIGENE DCS LBC.

  8. A Simple Model for Measuring Refractive Index of a Liquid Based upon Fresnel Equations

    Institute of Scientific and Technical Information of China (English)

    ZHANG Zhi-Wei; WU Zhi-Fang; WEN Ting-Dun

    2007-01-01

    Due to many experimental data required and a lot of calculations involved, it is very complex and cumbersome to model prism-based liquid-refractive-index-measuring methods. We develop a new method of mathematical modelling for measuring refractive index of a liquid based upon the Fresnel formula and prism internal reflection at an incident angle less than the critical angle. With this method, only two different concentrations measurements for a kind of solution can lead to the determination of computational model. Measurements are performed to examine the validity of the theoretical model. Experimental results indicate the feasibility of the theoretical model with an error of 1%. The method is also capable of measuring even smaller changes in the optical refractive index of the material on a metal surface by the surface plasma resonance sensing techniques.

  9. Ionic liquids based on S-alkylthiolanium cations and TFSI anion as potential electrolytes

    Institute of Scientific and Technical Information of China (English)

    ZHANG HuanQi; YANG Li; FANG ShaoHua; PENG ChengXin; LUO HongJun

    2009-01-01

    New ionic liquids based on S-alkylthiolanium cations with TFSI anions were synthesized and charac-terized.The physical and electrochemical properties,including melting point,thermal stability,solubil-ity,viscosity,conductivity and electrochemical window,were reported.Relation between these proper-ties and the structure of the cations was discussed.In this series,T4TFSI and T5TFSI have melting points below -60℃,and their conductivities are 2.10 mS/cm and 1.46 mS/cm;their electrochemical windows are 4.1 V and 4.5 V at room temperature.These cyclic alkylthiolanium-based ionic liquids are promising as novel electrolytes in various electrochemical devices,especially under low temperature condition.

  10. Ionic liquid-based microwave-assisted extraction of rutin from Chinese medicinal plants.

    Science.gov (United States)

    Zeng, Huan; Wang, Yuzhi; Kong, Jinhuan; Nie, Chan; Yuan, Ya

    2010-12-15

    An ionic liquid-based microwave-assisted extraction (ILMAE) method has been developed for the effective extraction of rutin from Chinese medicinal plants including Saururus chinensis (Lour.) Bail. (S. chinensis) and Flos Sophorae. A series of 1-butyl-3-methylimidazolium ionic liquids with different anions were investigated. The results indicated that the characteristics of anions have remarkable effects on the extraction efficiency of rutin and among the investigated ionic liquids, 1-butyl-3-methylimidazolium bromide ([bmim]Br) aqueous solution was the best. In addition, the ILMAE procedures for the two kinds of medicinal herbs were also optimized by means of a series of single factor experiments and an L(9) (3(4)) orthogonal design. Compared with the optimal ionic liquid-based heating extraction (ILHE), marinated extraction (ILME), ultrasonic-assisted extraction (ILUAE), the optimized approach of ILMAE gained higher extraction efficiency which is 4.879 mg/g in S. chinensis with RSD 1.33% and 171.82 mg/g in Flos Sophorae with RSD 1.47% within the shortest extraction time. Reversed phase high performance liquid chromatography (RP-HPLC) with ultraviolet detection was employed for the analysis of rutin in Chinese medicinal plants. Under the optimum conditions, the average recoveries of rutin from S. chinensis and Flos Sophorae were 101.23% and 99.62% with RSD lower than 3%, respectively. The developed approach is linear at concentrations from 42 to 252 mg L(-1) of rutin solution, with the regression coefficient (r) at 0.99917. Moreover, the extraction mechanism of ILMAE and the microstructures and chemical structures of the two researched samples before and after extraction were also investigated. With the help of LC-MS, it was future demonstrated that the two researched herbs do contain active ingredient of rutin and ionic liquids would not influence the structure of rutin.

  11. A comparison of liquid-based cytology with conventional Papanicolaou smears in cervical dysplasia diagnosis

    Science.gov (United States)

    Haghighi, Fatemeh; Ghanbarzadeh, Nahid; Ataee, Marziee; Sharifzadeh, Gholamreza; Mojarrad, Javid Shahbazi; Najafi-Semnani, Fatemeh

    2016-01-01

    Background: Due to the high number of women affected by cervical cancer and the importance of an early diagnosis, combined with the frequent incidence of false-negative Papanicolaou (Pap) smear screening results for this disease, several studies have been conducted in recent years in order to find better tests. Liquid-based cytology (LBC) tests, including the liquid-based thin layer method, have demonstrated the highest potential for reducing false-negative cases and improved sample quality. This study aimed to compare the strength of the Pap smear test with fluid cytology and conventional tests in detecting cervical dysplasia. Materials and Methods: This descriptive-analytic study was conducted on 366 women who attended private laboratories for a Pap smear. The Pap smear sampling was conducted simultaneously using two methods: conventional Pap (CP) smear and LBC), from the cervix. Results: The mean age of the participants was 32 ± 8.8 years. Diagnostic results of endocervical cells, epithelial cells, vaginitis cells, and metaplastia were consistent with both conventional and liquid cytology smears, and the kappa coefficient was determined to be significant (P < 0.001). In total, 40.5% of diagnostic cases indicated bacterial inflammation 80.3% of the diagnoses in both methods were P1 and 3.9% of cases diagnosed were P2, the overall diagnostic consistency was 83.9% between the two sampling methods. The inflammation diagnosis was 40.5% and this was consistent in both methods of LBC and CP. There was one case of a false-negative diagnosis in the LBC method and 14 cases in the CP method. Conclusion: Results showed that the LBC may improve the sample's quality and reduce the number of unsatisfactory cases more than with the CP method. PMID:27995101

  12. Outcomes of cervical liquid-based cytology suggesting a glandular abnormality.

    Science.gov (United States)

    Finall, A I; Olafsdottir, R

    2009-12-01

    To ascertain the positive predictive value of both ?glandular neoplasia (national standard code 6) and borderline change (national standard code 8) in glandular cells in liquid-based cervical cytology specimens in Cardiff and Vale NHS Trust and to outline the histological outcomes of these cases. Eighty-nine liquid-based (Surepath) cervical cytology cases were retrospectively identified from a 2-year period (January 2005 to December 2006) and correlated with histopathological diagnoses. Initial punch biopsy histology revealed 18 cases (21%) of cervical glandular intraepithelial neoplasia (CGIN). A further nine cases (10%) of CGIN were identified following local excision or hysterectomy. Ten cases of invasive malignancy were identified: four endocervical adenocarcinomas (all node negative, TNM stage T1b1), five endometrial adenocarcinomas and one squamous cell carcinoma. There were 10 with high-grade cervical intraepithelial neoplasia (CIN) alone. Women diagnosed with endometrial malignancy presented later with an average age of 64.6 years compared with 34.9 years for endocervical lesions. Taking high-grade CIN or worse as a positive outcome, the overall positive predictive value (PPV) of glandular abnormalities on cytology (both code 6 and 8) was 58.1% [95% confidence interval (CI) 47.8, 68.4]. PPV for borderline change in glandular cells alone was 24.1% (95% CI 8.5, 39.6) and for ?glandular neoplasia alone 75.4% (95% CI 64.3, 86.5). With our interpretation of the classification, women with cytological diagnoses of glandular neoplasia of the cervix should initially be investigated by local resection rather than punch biopsy, and those with borderline change in glandular cells with repeat cytology.

  13. Introduction of liquid-based cytology and human papillomavirus testing in cervical cancer screening in Luxembourg.

    Science.gov (United States)

    Latsuzbaia, Ardashel; Hebette, Gaëtan; Fischer, Marc; Arbyn, Marc; Weyers, Steven; Vielh, Philippe; Schmitt, Fernando; Mossong, Joël

    2017-05-01

    In 2014, liquid-based cytology with HPV triage replaced conventional cytology. The aim of our study was to compare conventional and liquid-based cytology (LBC), estimate the prevalence of abnormal cervical cytology and high risk HPV (hrHPV) infection and their correlation, among screened women in Luxembourg. Between the first January 2013 and 31st December 2015, 315,868 cervical samples from 150,815 women (mean age 42.2 years) were investigated by the national cytology laboratory. Slides were prepared and screened according to European Guidelines. All cytological results were classified according to the Bethesda 2001 system terminology. The prevalence of abnormal cervical lesions was as follows: atypical squamous cells of undetermined significance (ASC-US), 1.3%; low-grade squamous intraepithelial lesion (LSIL), 1.9%; high-grade squamous intraepithelial lesion (HSIL), 0.4%. The detection rate of cytological lesions was significantly higher with LBC than with conventional cytology. Based on 11,838 samples with concomitant cytology and HPV testing, hrHPV was detected in 9.5, 45.3, 70.0, and 92.6% of women with negative cytology, ASC-US, LSIL, and HSIL, respectively. More cervical lesions were identified using LBC compared to conventional cytology. HrHPV infection was correlated with the severity of intraepithelial lesions. The current findings provide important information to evaluate the prevention of cervical cancer in Luxembourg and for monitoring the future impact of HPV vaccination. Diagn. Cytopathol. 2017;45:384-390. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  14. A comparison of liquid-based cytology with conventional Papanicolaou smears in cervical dysplasia diagnosis.

    Science.gov (United States)

    Haghighi, Fatemeh; Ghanbarzadeh, Nahid; Ataee, Marziee; Sharifzadeh, Gholamreza; Mojarrad, Javid Shahbazi; Najafi-Semnani, Fatemeh

    2016-01-01

    Due to the high number of women affected by cervical cancer and the importance of an early diagnosis, combined with the frequent incidence of false-negative Papanicolaou (Pap) smear screening results for this disease, several studies have been conducted in recent years in order to find better tests. Liquid-based cytology (LBC) tests, including the liquid-based thin layer method, have demonstrated the highest potential for reducing false-negative cases and improved sample quality. This study aimed to compare the strength of the Pap smear test with fluid cytology and conventional tests in detecting cervical dysplasia. This descriptive-analytic study was conducted on 366 women who attended private laboratories for a Pap smear. The Pap smear sampling was conducted simultaneously using two methods: conventional Pap (CP) smear and LBC), from the cervix. The mean age of the participants was 32 ± 8.8 years. Diagnostic results of endocervical cells, epithelial cells, vaginitis cells, and metaplastia were consistent with both conventional and liquid cytology smears, and the kappa coefficient was determined to be significant (P < 0.001). In total, 40.5% of diagnostic cases indicated bacterial inflammation 80.3% of the diagnoses in both methods were P1 and 3.9% of cases diagnosed were P2, the overall diagnostic consistency was 83.9% between the two sampling methods. The inflammation diagnosis was 40.5% and this was consistent in both methods of LBC and CP. There was one case of a false-negative diagnosis in the LBC method and 14 cases in the CP method. Results showed that the LBC may improve the sample's quality and reduce the number of unsatisfactory cases more than with the CP method.

  15. [Accuracy of liquid-based cytology in diagnosis of high-grade squamous cervical intraepithelial neoplasia].

    Science.gov (United States)

    Li, Min; Mei, Ping; Luo, Dong-lan; Wang, Xiao-bing; Liu, Yan-hui

    2012-04-01

    To investigate factors affecting the diagnostic accuracy of cervical liquid-based cytology for high-grade squamous intraepithelial lesion (HSIL). A retrospective evaluation of cytological and histological slides was performed in 415 patients who had cytological HSIL between 2007 and 2010. Among 42 209 cases screened by ThinPrep liquid-based cytology, 415 cases (1.0%) of HSIL were eventually identified. The mean age of HSIL patients was 41.6 years, and 30-49 years were the most common age group. Among 415 cases, 325 patients had available histological diagnosis as follows: 23 (7.1%) negative, 22 (6.8%) CIN1/HPV, 223 (68.6%) CIN2/CIN3, and 57 (17.5%) squamous cell carcinoma (SCC). The positive predictive values of HSIL to predict CIN2 (or higher grade of dysplasia) and CIN1 were 86.2% (280/325) and 92.9% (302/325), respectively. Inadequate biopsy, reactive glandular cells, islet atrophy, chemo/radiotherapy and others were responsible for the cytologically false-positive diagnosis. Fifty-seven (17.5%) cases of HSIL had a histological diagnosis of SCC. The possible causes of misdiagnosis were social factors, under-recognized cytological features of poorly-differentiated SCC and absence of typical diagnostic features in cytology slides. Cytology of HSIL has a high positive predictive value for the presence of CIN2/CIN3 and SCC. Cytologists and gynecologists should be aware of the diagnostic pitfalls that may lead to the discrepancy between cytology and histology.

  16. Benefits of Cervical Cancer Screening by Liquid-Based Cytology as Part of Routine Antenatal Assessment.

    Science.gov (United States)

    Parkpinyo, Nichamon; Inthasorn, Perapong; Laiwejpithaya, Somsak; Punnarat, Tippawan

    2016-01-01

    To determine the prevalence of abnormal cervical cytology, as diagnosed using a liquid-based cytology technique, in pregnant women attending the Antenatal Care (ANC) clinic at Siriraj Hospital. This cross-sectional study included 655 first-visit pregnant women who attended ANC clinic at Siriraj Hospital during June to November 2015 study period. After receiving routine antenatal care, cervical cytology screening was performed with the Siriraj liquid-based cytology technique. All specimens were reviewed by a certi ed cytopathologist using Bethesda System 2001 criteria. Patients with abnormal PAP results characterized as epithelial cell abnormalities were referred to a gynecologic oncologist for further management according to ASCCP Guidelines 2012. Mean age of participants was 28.9±6.2 years. Prevalence of abnormal cervical cytology was 3.4% (95% CI: 2.0-4.7). Among this group, there were ASC-US, ASC-H, LSIL, HSIL for 12(1.8%), 2(0.3%), 7(1.1%) and 1(0.2%), respectively. In 633 specimens of the normal group, infection was identified in 158 specimens (24.1%) which were caused by Candida spp. and Trichomonas vaginalis. Regarding patient perception about the importance of cervical cancer screening, although most women perceived screening to be important, 54% of participants had never been screened for cervical cancer. Rate of loss to follow-up in the postpartum period was as high as 41.8%. Prevalence of abnormal cervical cytology in pregnant women attending the ANC clinic at Siriraj Hospital was 3.4%. Inclusion of cervical cancer screening as part of antenatal assessment can help to identify precancerous lesions or cervical cancers in patients who might otherwise not be screened, thereby facilitating early treatment and improved patient outcomes.

  17. Application of ionic liquids based enzyme-assisted extraction of chlorogenic acid from Eucommia ulmoides leaves

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Tingting; Sui, Xiaoyu, E-mail: suixiaoyu@outlook.com; Li, Li; Zhang, Jie; Liang, Xin; Li, Wenjing; Zhang, Honglian; Fu, Shuang

    2016-01-15

    A new approach for ionic liquid based enzyme-assisted extraction (ILEAE) of chlorogenic acid (CGA) from Eucommia ulmoides is presented in which enzyme pretreatment was used in ionic liquids aqueous media to enhance extraction yield. For this purpose, the solubility of CGA and the activity of cellulase were investigated in eight 1-alkyl-3-methylimidazolium ionic liquids. Cellulase in 0.5 M [C6mim]Br aqueous solution was found to provide better performance in extraction. The factors of ILEAE procedures including extraction time, extraction phase pH, extraction temperatures and enzyme concentrations were investigated. Moreover, the novel developed approach offered advantages in term of yield and efficiency compared with other conventional extraction techniques. Scanning electronic microscopy of plant samples indicated that cellulase treated cell wall in ionic liquid solution was subjected to extract, which led to more efficient extraction by reducing mass transfer barrier. The proposed ILEAE method would develope a continuous process for enzyme-assisted extraction including enzyme incubation and solvent extraction process. In this research, we propose a novel view for enzyme-assisted extraction of plant active component, besides concentrating on enzyme facilitated cell wall degradation, focusing on improvement of bad permeability of ionic liquids solutions. - Highlights: • An ionic liquid based enzyme-assisted extraction method of natural product was explored. • ILEAE utilizes enzymatic treatment to improve permeability of ionic liquids solution. • Enzyme incubation and solvent extraction process were ongoing simultaneously. • ILEAE process simplified operating process and suitable for more complete extraction.

  18. [Health technology assessment report. Use of liquid-based cytology for cervical cancer precursors screening].

    Science.gov (United States)

    Ronco, Guglielmo; Confortini, Massimo; Maccallini, Vincenzo; Naldoni, Carlo; Segnan, Nereo; Sideri, Mario; Zappa, Marco; Zorzi, Manuel; Calvia, Maria; Giorgi Rossi, Paolo

    2012-01-01

    OBJECTIVE OF THE PROJECT: Purpose of this Report is to evaluate the impact of the introduction of liquid-based cytology (LBC) in cervical cancer screening in terms of efficacy, undesired effects, costs and implications for organisation. EFFICACY AND UNDESIRED EFFECTS: LBC WITH MANUAL INTERPRETATION: The estimates of cross-sectional accuracy for high-grade intraepithelial neoplasia (CIN2 or more severe and CIN3 or more severe) obtained by a systematic review and meta-analysis published in 2008 were used. This review considered only studies in which all women underwent colposcopy or randomised controlled trials (RCTs) with complete verification of test positives. A systematic search of RCTs published thereafter was performed. Three RCTs were identified. One of these studies was conducted in 6 Italian regions and was of large size (45,174 women randomised); a second one was conducted in another Italian region (Abruzzo) and was of smaller size (8,654 women randomised); a third RCT was conducted in the Netherlands and was of large size (89,784 women randomised). No longitudinal study was available. There is currently no clear evidence that LBC increases the sensitivity of cytology and even less that its introduction increases the efficacy of cervical screening in preventing invasive cancers. The Italian randomised study NTCC showed a decrease in specificity, which was not observed in the other two RCTs available. In addition, the 2008 meta-analysis observed a reduction - even if minimal - in specificity just at the ASC-US cytological cut-off, but also a remarkable heterogeneity between studies. These results suggest that the effect of LBC on specificity is variable and plausibly related to the local style of cytology interpretation. There is evidence that LBC reduces the proportion of unsatisfactory slides, although the size of this effect varies remarkably. LBC WITH COMPUTER-ASSISTED INTERPRETATION: An Australian study, based on double testing, showed a statistically

  19. Recent developments in dispersive liquid-liquid microextraction.

    Science.gov (United States)

    Saraji, Mohammad; Boroujeni, Malihe Khalili

    2014-03-01

    During the past 7 years and since the introduction of dispersive liquid-liquid microextraction (DLLME), the method has gained widespread acceptance as a simple, fast, and miniaturized sample preparation technique. Owing to its simplicity of operation, rapidity, low cost, high recovery, and low consumption of organic solvents and reagents, it has been applied for determination of a vast variety of organic and inorganic compounds in different matrices. This review summarizes the DLLME principles, historical developments, and various modes of the technique, recent trends, and selected applications. The main focus is on recent technological advances and important applications of DLLME. In this review, six important aspects in the development of DLLME are discussed: (1) the type of extraction solvent, (2) the type of disperser solvent, (3) combination of DLLME with other extraction methods, (4) automation of DLLME, (5) derivatization reactions in DLLME, and (6) the application of DLLME for metal analysis. Literature published from 2010 to April 2013 is covered.

  20. Cytologic detection of cervical abnormalities using liquid-based compared with conventional cytology: a randomized controlled trial.

    NARCIS (Netherlands)

    Siebers, A.G.; Klinkhamer, P.J.; Arbyn, M.; Raifu, A.O.; Massuger, L.F.A.G.; Bulten, J.

    2008-01-01

    OBJECTIVE: To compare test positivity rates of liquid-based and conventional cytology. METHODS: This study was a cluster randomized controlled trial with family practice as the unit of randomization, performed within the Dutch national cervical screening program. Women aged 30-60 years (n=89,784) re

  1. Causes and relevance of unsatisfactory and satisfactory but limited smears of liquid-based compared with conventional cervical cytology.

    NARCIS (Netherlands)

    Siebers, A.G.; Klinkhamer, P.J.; Vedder, J.E.M.; Arbyn, M.; Bulten, J.

    2012-01-01

    CONTEXT: Recent randomized controlled trials have shown a significant decrease in unsatisfactory rates for liquid-based cytology (LBC) compared with conventional Papanicolaou test (CP). The underlying causes and relevance of unsatisfactory results for LBC and CP have never been compared within the s

  2. European guidelines for quality assurance in cervical cancer screening: recommendations for collecting samples for conventional and liquid-based cytology.

    NARCIS (Netherlands)

    Arbyn, M.; Herbert, A.; Schenck, U.; Nieminen, P.; Jordan, J.; Mcgoogan, E.; Patnick, J.; Bergeron, C.; Baldauf, J.J.; Klinkhamer, P.; Bulten, J.; Martin-Hirsch, P.

    2007-01-01

    The current paper presents an annex in the second edition of the European Guidelines for Quality Assurance in Cervical Cancer Screening. It provides guidance on how to make a satisfactory conventional Pap smear or a liquid-based cytology (LBC) sample. Practitioners taking samples for cytology should

  3. Superior performance of liquid-based versus conventional cytology in a population-based cervical cancer screening program

    NARCIS (Netherlands)

    Beerman, H.; van Dorst, E. B. L.; Kuenen-Boumeester, V.; Hogendoorn, P. C. W.

    2009-01-01

    Objective. Liquid-based cytology may offer improvements over conventional cytology for cervical cancer screening. The two cytology techniques were compared in a group of 86,469 women who participated in a population-based screening program. Using a nation-wide pathology database containing both cerv

  4. Comparative study of the results from conventional cervico-vaginal oncotic cytology and liquid-based cytology

    OpenAIRE

    Stabile,Sueli Aparecida Batista; Evangelista,Dilson Henrique Ramos; Talamonte,Valdely Helena; Lippi,Umberto Gazi; Lopes, Reginaldo Guedes Coelho

    2012-01-01

    OBJECTIVE: To compare two oncotic cervical cytology techniques, the conventional and the liquid-based cytology, in low risk patients for uterine cervical cancer. METHODS: Comparative prospective study with 100 patients who came to their annual gynecological exam, and were submitted simultaneously to both techniques. We used the McNemar test, with a significance level of p

  5. Is an alcoholic fixative fluid used for manual liquid-based cytology accurate to perform HPV tests?

    Directory of Open Access Journals (Sweden)

    Garbar C

    2011-12-01

    Full Text Available Christian Garbar1, Corinne Mascaux1, Philippe De Graeve2, Philippe Delvenne31Department of Biopathology, Institute Jean Godinot, Reims Cedex, France; 2Centre de Pathologie des Coteaux, Toulouse, France; 3Department of Pathology, University of Liege, Tour de Pathologie, Domaine Universitaire du Sart Tilman, Liège, BelgiumAbstract: In Europe, the alternative centrifuge method of liquid-based cytology is widely used in cervical screening. Turbitec® (Labonord SAS, Templemars, France is a centrifuge method of liquid-based cytology using an alcoholic fixative fluid, Easyfix® (Labonord. It is now well accepted that the association of liquid-based cytology and human papillomavirus test is indissociable of cervical screening. The aim of this work was to demonstrate that Easyfix alcoholic fluid is reliable to perform Hybrid Capture® 2 (QIAGEN SAS, Courtaboeuf, France. In this study, 75 patients with colposcopy for cervical lesions served as gold standard. A sample was collected, at random, for Easyfix fixative cytological fluid and for Digene Cervical Sampler (QIAGEN. The results of Hybrid Capture 2 (with relative light unit >1 showed no statistical difference, a positive Spearman’s correlation (r = 0.82, P < 0.0001, and a kappa value of 0.87 (excellent agreement between the two fluids. It was concluded that Easyfix is accurate to use in human papillomavirus tests with Hybrid Capture 2.Keywords: human papillomavirus, hybrid capture 2, Turbitec®, cervix cytology, liquid-based cytology

  6. Causes and relevance of unsatisfactory and satisfactory but limited smears of liquid-based compared with conventional cervical cytology.

    NARCIS (Netherlands)

    Siebers, A.G.; Klinkhamer, P.J.; Vedder, J.E.M.; Arbyn, M.; Bulten, J.

    2012-01-01

    CONTEXT: Recent randomized controlled trials have shown a significant decrease in unsatisfactory rates for liquid-based cytology (LBC) compared with conventional Papanicolaou test (CP). The underlying causes and relevance of unsatisfactory results for LBC and CP have never been compared within the s

  7. Superior performance of liquid-based versus conventional cytology in a population-based cervical cancer screening program

    NARCIS (Netherlands)

    Beerman, H.; van Dorst, E. B. L.; Kuenen-Boumeester, V.; Hogendoorn, P. C. W.

    2009-01-01

    Objective. Liquid-based cytology may offer improvements over conventional cytology for cervical cancer screening. The two cytology techniques were compared in a group of 86,469 women who participated in a population-based screening program. Using a nation-wide pathology database containing both cerv

  8. Cytologic detection of cervical abnormalities using liquid-based compared with conventional cytology: a randomized controlled trial.

    NARCIS (Netherlands)

    Siebers, A.G.; Klinkhamer, P.J.; Arbyn, M.; Raifu, A.O.; Massuger, L.F.A.G.; Bulten, J.

    2008-01-01

    OBJECTIVE: To compare test positivity rates of liquid-based and conventional cytology. METHODS: This study was a cluster randomized controlled trial with family practice as the unit of randomization, performed within the Dutch national cervical screening program. Women aged 30-60 years (n=89,784) re

  9. Liquid-based endometrial cytology associated with curettage in the investigation of endometrial carcinoma in postmenopausal women.

    Science.gov (United States)

    Ma, Ke; Yang, Xi; Chen, Rui; Zhao, Jian; Dong, Ying; Zhang, Nai-Yi; Ma, Xiu-Hua; Liao, Qin-Ping

    2016-12-01

    The aim of this study was to investigate the diagnostic accuracy of liquid-based endometrial cytology in postmenopausal women, in comparison with histology. There were 790 postmenopausal women scheduled for hysteroscopy enrolled in this study. After providing informed consent, all patients proceeded sequentially through endometrial cytology, hysteroscopy, and then dilatation and curettage (D&C). Cytology sampling was performed by brushing the uterus cavity using SAP-1 and the sample was prepared to liquid-based smear using SurePath technology. The slides were stained by Papanicolaou method. All cytological diagnoses were correlated with the D&C histological diagnoses. Cytohistological correlations were possible in 567 (71.8%) patients: the D&C was inadequate in 204 (25.8%) patients; the cytology was inadequate in 32 (4.1%) patients; and both were inadequate in 13 (1.6%) patients. SAP-1 provided more sufficient material for cytology than D&C can for histology (p liquid-based endometrial cytology was 81.5%; sensitivity was estimated at 75.9%, specificity at 83.3%, positive predictive value at 59.1% and negative predictive value at 91.6%. Liquid-based endometrial cytology can be considered a useful method in the detection of endometrial pathology in postmenopausal women. Copyright © 2016. Published by Elsevier B.V.

  10. European guidelines for quality assurance in cervical cancer screening: recommendations for collecting samples for conventional and liquid-based cytology.

    NARCIS (Netherlands)

    Arbyn, M.; Herbert, A.; Schenck, U.; Nieminen, P.; Jordan, J.; Mcgoogan, E.; Patnick, J.; Bergeron, C.; Baldauf, J.J.; Klinkhamer, P.; Bulten, J.; Martin-Hirsch, P.

    2007-01-01

    The current paper presents an annex in the second edition of the European Guidelines for Quality Assurance in Cervical Cancer Screening. It provides guidance on how to make a satisfactory conventional Pap smear or a liquid-based cytology (LBC) sample. Practitioners taking samples for cytology should

  11. Superior performance of liquid-based versus conventional cytology in a population-based cervical cancer screening program

    NARCIS (Netherlands)

    Beerman, H.; van Dorst, E. B. L.; Kuenen-Boumeester, V.; Hogendoorn, P. C. W.

    Objective. Liquid-based cytology may offer improvements over conventional cytology for cervical cancer screening. The two cytology techniques were compared in a group of 86,469 women who participated in a population-based screening program. Using a nation-wide pathology database containing both

  12. A numerical study into the effects of elongated capsules on the healing efficiency of liquid-based systems

    NARCIS (Netherlands)

    Mookhoek, S.D.; Fischer, H.R.; Zwaag, S. van der

    2009-01-01

    In this numerical study the release of healing agent for liquid-based self-healing systems for elongated microcapsules is studied and compared with that for the usual spherical capsules. It is shown that a high aspect ratio and a proper spatial orientation of the elongated capsules have a positive

  13. Recovery of culturable of Escherichia coli O157:H7 during operation of a liquid-based bioaerosol sampler

    Science.gov (United States)

    Collection fluids used in liquid-based bioaerosol samplers can influence the viability of microorganisms. In this study we determined the recovery efficiency of vegetative E. coli O157:H7 cells that were spiked into low viscosity evaporating collection fluids during operation of a BioSampler™ for up...

  14. The impact of liquid-based oral cytology on the diagnosis of oral squamous dysplasia and carcinoma.

    Science.gov (United States)

    Navone, R; Burlo, P; Pich, A; Pentenero, M; Broccoletti, R; Marsico, A; Gandolfo, S

    2007-12-01

    Even though diagnostic oral exfoliative cytology is a useful, economical and practical tool in the diagnosis of oral dysplasia and carcinoma, it is not yet extensively used. The results of conventional exfoliative and liquid-based diagnostic cytology in oral potentially malignant lesions (PML) are herein reported and compared with the histological diagnosis. Either conventional (89) or liquid-based (384) exfoliative cytology was used for the diagnosis of oral dysplasia/carcinoma in 473 subjects and the results were compared with scalpel biopsy histology. Cells were collected using a Cytobrush device for conventional smears and with a dermatological curette for the liquid-based cytology. The 'curette technique' also allowed for the collection of 'accidental' tissue fragments, utilized as microbiopsies. Histological diagnosis was squamous carcinoma in 96 of 473 cases, high-grade dysplasia (oral intraepithelial neoplasia two to three) in 24 and other lesions in 353 cases. The smears in the conventional cytology group were inadequate in 12.4%, with an 85.7% sensitivity and a 95.9% specificity. There were 8.8% of inadequate specimens in the liquid-based cytology group; sensitivity was 95.1% and specificity was 99.0%. Although conventional cytology is useful when diagnosing oral PML (better sensitivity and predictive positive value if compared with the cervical smear test with similar specificity) and can improve the accuracy of histological diagnosis, liquid-based cytology gives better results, as it not only enhances both sensitivity and specificity, but also provides material for further investigation (AgNORs, DNA, microbiopsies, etc.).

  15. Liquid-based endometrial cytology associated with curettage in the investigation of endometrial carcinoma in a population of 1987 women.

    Science.gov (United States)

    Yang, Xi; Ma, Ke; Chen, Rui; Zhao, Jian; Wu, Cheng; Zhang, Naiyi; Ma, Xiuhua; Dong, Ying; Zhu, Sainan; Liao, Qinping

    2017-07-01

    The aim of this study was to investigate the diagnostic accuracy of liquid-based endometrial cytology, in comparison with histology. 1987 patients scheduled for hysteroscopy were enrolled in this study. All patients proceeded sequentially through endometrial cytology, hysteroscopy and then dilatation and curettage (D&C). Cytology sampling was performed by brushing the uterus cavity using SAP-1 and the sample was prepared to liquid-based smear using SurePath technology. The slides were stained by Papanicolaou method. All cytological diagnosis was correlated with the D&C histological diagnosis. Cyto-histological correlations were possible in 1672 (89.3%) patients: in 254 (12.8%) patients the D&C was inadequate, in 75 (3.8%) patients the cytology was inadequate, and in 14 (0.7%) patients both were inadequate. In postmenopausal women, 758 of 790 cytologies (96.0%) were adequate, while 586 of 790 histologies (74.2%) were adequate. SAP-1 provided more sufficient materials for cytology than D&C for histology (P liquid-based endometrial cytology was 86.1%, sensitivity was estimated at 70.3%, specificity at 88.5%, positive predictive value at 48.0% and negative predictive value at 95.2%. Taking endometrial carcinoma as a positive result, the diagnostic accuracy of liquid-based endometrial cytology was 94.4%; sensitivity was estimated at 53.2%, specificity at 98.6%, positive predictive value at 79.8% and negative predictive value at 95.3%. Liquid-based endometrial cytology can be considered a useful method for detecting of endometrial pathology as a first-line approach.

  16. Improvization of conventional cytology by centrifuged liquid-based cytology in oral exfoliative cytology specimen

    Directory of Open Access Journals (Sweden)

    Shwetha Nambiar

    2016-01-01

    Full Text Available Background: Exfoliative cytology is the microscopic examination of shed or desquamated cells from the epithelial surface. Centrifuged liquid-based cytology (CLBC is a modified technique that was used in the current study. Aims: To compare the efficacy of CLBC with conventional cytology in apparently normal mucosa after staining with Papanicolaou (PAP stain. Materials and Methods: Fifty cases of apparently normal mucosa from healthy subjects were selected for the study. The first sample was taken and spread on the slide by the conventional technique. The second sample was flushed out in a suspending solution, centrifuged, and the cell pellet obtained was used to make the smear. The stained smears were compared for seven parameters such as adequate cellularity, clear background, uniform distribution, cellular overlapping, cellular elongation, mucus, and inflammatory cells. Chi-square test was used for statistical analysis and P ≤ 0.05 was considered to be statistically significant. Results: There was a statistically significant difference between CLBC and conventional cytology with parameters such as adequate cellularity (P = 0.001, clear background (P = 0.001, uniform distribution (0.005, cellular overlapping, and cellular elongation (P = 0. The presence of mucus and inflammatory cells was minimal as the samples were collected from healthy subjects. Conclusion: CLBC has better efficacy over the conventional method in all the parameters analyzed.

  17. Improvization of conventional cytology by centrifuged liquid-based cytology in oral exfoliative cytology specimen.

    Science.gov (United States)

    Nambiar, Shwetha; Hegde, Veda; Yadav, Nikhil; Hallikeri, Kaveri

    2016-01-01

    Exfoliative cytology is the microscopic examination of shed or desquamated cells from the epithelial surface. Centrifuged liquid-based cytology (CLBC) is a modified technique that was used in the current study. To compare the efficacy of CLBC with conventional cytology in apparently normal mucosa after staining with Papanicolaou (PAP) stain. Fifty cases of apparently normal mucosa from healthy subjects were selected for the study. The first sample was taken and spread on the slide by the conventional technique. The second sample was flushed out in a suspending solution, centrifuged, and the cell pellet obtained was used to make the smear. The stained smears were compared for seven parameters such as adequate cellularity, clear background, uniform distribution, cellular overlapping, cellular elongation, mucus, and inflammatory cells. Chi-square test was used for statistical analysis and P ≤ 0.05 was considered to be statistically significant. There was a statistically significant difference between CLBC and conventional cytology with parameters such as adequate cellularity (P = 0.001), clear background (P = 0.001), uniform distribution (0.005), cellular overlapping, and cellular elongation (P = 0). The presence of mucus and inflammatory cells was minimal as the samples were collected from healthy subjects. CLBC has better efficacy over the conventional method in all the parameters analyzed.

  18. APPLICATION OF LIQUID-BASED CYTOLOGY TO FINE-NEEDLE ASPIRATION BIOPSIES OF THE THYROID GLAND

    Directory of Open Access Journals (Sweden)

    Guido eFadda

    2012-05-01

    Full Text Available FNAB (fine-needle aspiration biopsy is regarded as an important tool for diagnosing thyroid lesions because of its simplicity, safety and cost-effectiveness. Its role in correctly characterizing the group of indeterminate lesions or follicular-patterned neoplasms (FN might be more decisive. LBC (Liquid-based cytology is a technique based on the use of a semi-automated device that has gained popularity as a method of collecting and processing both gynecologic and non-gynecologic cytologic specimens. It achieves a diagnostic sensitivity as accurate as conventional preparations especially for its excellent cell preservation and for the lack of background which decrease the amount of inadequate diagnoses. Moreover, the cellular material which has been stored in the preservative solution could be effectively used for the application of immunocytochemical and molecular techniques used especially for the Follicular proliferations . In many cases the cytologic features are similar in both methods but the colloid film and the lymphocytic component are more easily evaluated on direct smears whereas nuclear details and colloid globules are better evaluated in LBC slides. The LBC processed biopsies represent a valid alternative to conventional cytology. The possibility of applying special techniques enhance the efficacy of the cytological diagnosis of thyroid lesions.

  19. Comparison of Efficacy in Abnormal Cervical Cell Detection between Liquid-based Cytology and Conventional Cytology.

    Science.gov (United States)

    Tanabodee, Jitraporn; Thepsuwan, Kitisak; Karalak, Anant; Laoaree, Orawan; Krachang, Anong; Manmatt, Kittipong; Anontwatanawong, Nualpan

    2015-01-01

    This study was conducted to 1206 women who had cervical cancer screening at Chonburi Cancer Hospital. The spilt-sample study aimed to compare the efficacy of abnormal cervical cells detection between liquid-based cytology (LBC) and conventional cytology (CC). The collection of cervical cells was performed by broom and directly smeared on a glass slide for CC then the rest of specimen was prepared for LBC. All slides were evaluated and classified by The Bethesda System. The results of the two cytological tests were compared to the gold standard. The LBC smear significantly decreased inflammatory cell and thick smear on slides. These two techniques were not difference in detection rate of abnormal cytology and had high cytological diagnostic agreement of 95.7%. The histologic diagnosis of cervical tissue was used as the gold standard in 103 cases. Sensitivity, specificity, positive predictive value, negative predictive value, false positive, false negative and accuracy of LBC at ASC-US cut off were 81.4, 75.0, 70.0, 84.9, 25.0, 18.6 and 77.7%, respectively. CC had higher false positive and false negative than LBC. LBC had shown higher sensitivity, specificity, PPV, NPV and accuracy than CC but no statistical significance. In conclusion, LBC method can improve specimen quality, more sensitive, specific and accurate at ASC-US cut off and as effective as CC in detecting cervical epithelial cell abnormalities.

  20. Study of a manual method of liquid-based cervical cytology

    Directory of Open Access Journals (Sweden)

    Kavatkar Anita

    2008-04-01

    Full Text Available We report a study of a manual liquid-based cytology (MLBC method. Slides are prepared by using a polymer solution and allowing it to dry, forming a membrane. The aims of the study were to prepare cervical cytology smears using the manual method, observe morphology, compare with direct scrape smears and correlate with histopathology wherever possible. Out of 105 cases, the membrane was intact, indicating a good MLBC preparation, in 97 cases. Simultaneous conventional smears were taken in 81 patients. There was an 88.8% agreement in the diagnoses of general category in both groups. The diagnosis of negative for intraepithelial lesion or malignancy (NILM in both groups was made in 70 cases. The MLBC preparation was unsatisfactory in two cases which showed high grade squamous intraepithelial lesion and low grade squamous intraepithelial lesion, respectively, on the conventional smear. One MLBC smear diagnosed as atypical squamous cells of undetermined significance was reported as NILM on conventional smear. Cytohistologic correlation was done in nine cases, all of which showed cervicitis on histopathology. The MLBC method was found to be comparable to the conventional scrape smear. Further study of this method as a cost-effective alternative to the mechanized methods would be worthwhile.

  1. Usefulness of liquid-based cytology in hormone receptor analysis of breast cancer specimens.

    Science.gov (United States)

    Nishimura, Rieko; Aogi, Kenjiro; Yamamoto, Tamami; Takabatake, Daisuke; Takashima, Seiki; Teramoto, Norihiro; Kagawa, Akihiro; Morita, Sachiko

    2011-02-01

    Immunohistochemical (IHC) analysis of the hormone receptor (HR) in breast cancer cytology is an important issue nowadays. Several studies have shown discrepancy in the HR status between the primary tumor and metastases. Cytology can be used for patients with metastatic disease. Although cytological assessment of HR is an excellent method, it has not been routinely used because of the difficulty in consistently preparing multiple good quality slides. Liquid-based cytology (LBC) preparation is considered as the key to resolving the aforementioned problem; however, few studies have reported the HR assessment in breast cancer using LBC. Therefore, the HR status of LBC slides from 82 breast cancers was compared with that of the corresponding surgical specimens. The HR assay in both the LBC slides and surgical specimens was conducted by IHC using an autostainer. For the IHC staining, the protocol recommended by the manufacturer for paraffin-embedded sections was used for both the cytology and histology specimens. The HR results of the cytology agreed with those of the histology in 80 of the 82 cases (accuracy rate, 98%) for estrogen receptor, and in 78 of the 82 cases (accuracy rate, 95%) for progesterone receptor. The overall accuracy of the HR status on the cytology and the histology was 99% in 81 of the 82 cases. In conclusion, in HR analysis of breast cancers, LBC followed by IHC using an autostainer was useful for the standard processing of cytological specimens and showed a good correlation with the results of analysis on the histology specimens.

  2. EGFR mutations detection on liquid-based cytology: is microscopy still necessary?

    Science.gov (United States)

    Malapelle, Umberto; de Rosa, Nicla; Bellevicine, Claudio; Rocco, Danilo; Vitiello, Fabiana; Piantedosi, Franco Vito; Illiano, Alfonso; Nappi, Oscar; Troncone, Giancarlo

    2012-06-01

    Currently, there is a trend towards an increasing use of liquid-based cytology (LBC) to diagnose non-small cell lung cancer. In this study, to detect epidermal growth factor receptor mutations, different molecular techniques were applied to LBC samples with and without laser capture microdissection (LCM). In 58 LBCs, DNA was extracted twice. One sample was obtained directly from CytoLyt solution, whereas the other DNA sample was derived after slide preparation and LCM of Papanicolaou-stained cells. The rate of mutant cases obtained by direct sequencing was discordant between CytoLyt-derived (10.3%) and LCM-derived (17.2%) DNA. However, the same mutant rate (17.2%) was achieved on the matched samples by high-resolution melting analysis, fragment and TaqMan assays. Thus, LCM and direct sequencing may be replaced by more sensitive non-sequencing methods directly performed on CytoLyt-derived DNA, an easier and faster approach to improve epidermal growth factor receptor testing standardisation on LBCs.

  3. Non-gynecologic cytology on liquid-based preparations: A morphologic review of facts and artifacts.

    Science.gov (United States)

    Hoda, Rana S

    2007-10-01

    Liquid-based preparations (LBP) are increasingly being used both for gynecologic (gyn) and non-gynecologic (non-gyn) cytology including fine needle aspirations (FNA). The two FDA-approved LBP currently in use include ThinPrep (TP), (Cytyc Corp, Marlborough, MA) and SurePath (SP), (TriPath Imaging Inc., Burlington, NC). TP was approved for cervico-vaginal (Pap test) cytology in 1996 and SP in 1999 and both have since also been used for non-gyn cytology. In the LBP, instead of being smeared, cells are rinsed into a liquid preservative collection medium and processed on automated devices. Even after a decade of use, the morphological interpretation of LBP remains a diagnostic challenge because of somewhat altered morphology and artifacts or facts resulting from the fixation and processing techniques. These changes include cleaner background with altered or reduced background and extracellular elements; architectural changes such as smaller cell clusters and sheets, breakage of papillae; altered cell distribution with more dyscohesion and changes in cellular morphology with enhanced nuclear features, smaller cell size and slightly more three-dimensional (3-D) clusters. Herein, we review the published literature on morphological aspects of LBP for non-gyn cytology.

  4. Application of ionic liquid-based microwave-assisted extraction of flavonoids from Scutellaria baicalensis Georgi.

    Science.gov (United States)

    Zhang, Qin; Zhao, San-Hu; Chen, Jue; Zhang, Li-Wei

    2015-10-01

    In the present work, a rapid ionic liquid-based microwave-assisted extraction (ILMAE) method was successfully applied to simultaneous extraction of baicalin, wogonoside, baicalein and wogonin from Scutellaria baicalensis Georgi. A series of 1-alkyl-3-methylirnidazolium ionic liquids with different anions and cations were assessed for extraction efficiency, and 1-octyl-3-methylimidazolium bromide was selected as the optimal solvent. In addition, the parameters of ILMAE procedure for the four flavonoids were optimized, and the optimal ILMAE method was validated in the linearity, stability, precision and recovery. Meanwhile, the microstructures of S. baicalensis powders were observed before and after extraction with the help of a scanning electron microscope (SEM) in order to explore the extraction mechanism, and the activity of the crude enzyme solution from S. baicalensis was determined through the hydrolysis of baicalin. Finally, the extraction yields and extraction time of WaterHRE, WaterMAE, ILHRE and Chp were 5.18% (30min), 8.77% (90s), 16.94% (30min) and 18.58% (3h), respectively. The results indicated that compared with the conventional extraction approaches, ILMAE possessed great advantages in extracting flavonoids, such as the highest extraction yield (22.28%), the shortest extraction time (90s), etc.

  5. Determination of heat capacity of ionic liquid based nanofluids using group method of data handling technique

    Science.gov (United States)

    Sadi, Maryam

    2017-07-01

    In this study a group method of data handling model has been successfully developed to predict heat capacity of ionic liquid based nanofluids by considering reduced temperature, acentric factor and molecular weight of ionic liquids, and nanoparticle concentration as input parameters. In order to accomplish modeling, 528 experimental data points extracted from the literature have been divided into training and testing subsets. The training set has been used to predict model coefficients and the testing set has been applied for model validation. The ability and accuracy of developed model, has been evaluated by comparison of model predictions with experimental values using different statistical parameters such as coefficient of determination, mean square error and mean absolute percentage error. The mean absolute percentage error of developed model for training and testing sets are 1.38% and 1.66%, respectively, which indicate excellent agreement between model predictions and experimental data. Also, the results estimated by the developed GMDH model exhibit a higher accuracy when compared to the available theoretical correlations.

  6. Ionic liquid-based zwitterionic organic polymer monolithic column for capillary hydrophilic interaction chromatography.

    Science.gov (United States)

    Wang, Tingting; Chen, Yihui; Ma, Junfeng; Zhang, Xiaodan; Zhang, Lihua; Zhang, Yukui

    2015-08-21

    In the current study, a novel ionic liquid-based zwitterionic organic polymer monolithic column was developed by copolymerizing 1-vinyl-3-(butyl-4-sulfonate) imidazolium, acrylamide and N,N'-methylenebisacrylamide in a quaternary porogenic solvent consisting of formamide, dimethyl sulphoxide, polyethylene glycol 8000 and polyethylene glycol 10,000 for capillary hydrophilic interaction chromatography. The monolithic stationary phase was optimized by adjusting the amount of monomer in the polymerization solution along with the composition of porogenic solvent. The optimized monolith exhibited excellent selectivity and favorable retention for nucleosides and benzoic acid derivatives. The primary factors affecting the separation efficiency of the monolithic column (including acetonitrile content, pH, and buffer salt concentration in the mobile phase) have been thoroughly evaluated. Excellent reproducibility of the retention times for five nucleosides was achieved, with relative standard deviations of run-to-run (n = 3), column-to-column (n = 3) and batch-to-batch (n = 3) in the range of 0.18-0.48%, 2.33-4.20% and 3.07-6.50%, respectively.

  7. Liquid based cytology improves the positive predictive value of glandular smears compared to conventional cytology.

    Science.gov (United States)

    Edmondson, R J; Errington, C A; Mansour, D J A

    2010-01-01

    To investigate whether the introduction of liquid-based cytology (LBC) in an urban setting decreases the diagnosis of glandular neoplasia (grade 6) and improves the positive predictive value (PPV) of cervical cytological screening. A retrospective database review was conducted identifying women with cervical cytological abnormalities including glandular neoplasia (grade 6) before and after the introduction of LBC. Following the introduction of LBC the rate of glandular neoplasia (grade 6) referrals fell from 1.08% to 0.69% of all cervical cytological abnormalities. There was a significant reduction in 'abnormal' cytological samples subsequently found to be associated with no invasive or preinvasive disease but no decrease in the number showing preinvasive or invasive disease. A significant decrease in number of patients having a final diagnosis of normal/inflammatory or wart changes was seen in those patients referred during the LBC period (p cytological glandular neoplasia referrals but not at the expense of missing preinvasive and invasive cancers. It has also increased the PPV of cervical sampling to detect preinvasive and invasive cancer from 59.6% to 76.0%.

  8. Application of liquid-based cytology to fine-needle aspiration biopsies of the thyroid gland.

    Science.gov (United States)

    Rossi, Esther Diana; Zannoni, Gian Franco; Moncelsi, Stefania; Stigliano, Egidio; Santeusanio, Giuseppe; Lombardi, Celestino Pio; Pontecorvi, Alfredo; Fadda, Guido

    2012-01-01

    Fine-needle aspiration biopsy is regarded as an important tool for diagnosing thyroid lesions because of its simplicity, safety, and cost-effectiveness. Its role in correctly characterizing the group of indeterminate lesions or follicular-patterned neoplasms (FN) might be more decisive. Liquid-based cytology (LBC) is a technique based on the use of a semi-automated device that has gained popularity as a method of collecting and processing both gynecologic and non-gynecologic cytologic specimens. It achieves a diagnostic sensitivity as accurate as conventional preparations especially for its excellent cell preservation and for the lack of background which decrease the amount of inadequate diagnoses. Moreover, the cellular material which has been stored in the preservative solution could be effectively used for the application of immunocytochemical and molecular techniques especially for the Follicular proliferations. In many cases the cytologic features are similar in both methods but the colloid film and the lymphocytic component are more easily evaluated on direct smears whereas nuclear details and colloid globules are better evaluated in LBC slides. The LBC-processed biopsies represent a valid alternative to conventional cytology. The possibility of applying special techniques enhance the efficacy of the cytological diagnosis of thyroid lesions.

  9. Is liquid-based cytology the magic bullet for performing molecular techniques?

    Science.gov (United States)

    Abedi-Ardekani, Behnoush; Vielh, Philippe

    2014-01-01

    The role of pathology has evolved from the first microscopic definitions of diseases by Virchow to the new concept of molecular cytopathology. The management of diseases is now a multidisciplinary approach with the translation of morphological, imagery and molecular findings to therapeutic protocols. Obtaining the most reliable diagnostic material is the essential part of the medical management of patients. Here, we try to gain a concise insight into the available data regarding the role of cytology in the application of molecular techniques, focusing on cancer cytopathology. Obtaining cytological material is now feasible by different methods, and in some cases it is the only possible approach to a lesion which is not easily accessible for tissue sampling. The methods of obtaining cytological material have evolved in recent years in parallel with rapid advances in high-throughput molecular techniques, opening new windows for the diagnosis and management of diseases. Different kinds of cytological material are reliable for the application of molecular techniques. Cytological material obtained in a liquid base has advantages such as the better preservation of cytomorphological features and the use of the remaining liquid for nucleic acid extraction even after long storage and the application of molecular methods.

  10. Interlaboratory variation in the performance of liquid-based cytology: insights from the ATHENA trial.

    Science.gov (United States)

    Wright, Thomas C; Stoler, Mark H; Behrens, Catherine M; Sharma, Abha; Sharma, Keerti; Apple, Raymond

    2014-04-15

    Although it is recognized that cervical cytology is highly subjective, and that there is considerable interlaboratory variation in how slides are evaluated, little is known as to how this impacts the performance of cytology. In the ATHENA trial, liquid-based cytology specimens from 46,887 eligible women ≥21 years of age were evaluated at four large regional US laboratories, providing a unique opportunity to evaluate the impact of interlaboratory variations on the performance of cervical cytology. All women with abnormal cytology (atypical squamous cells of undetermined significance or higher) were referred to colposcopy, as were all high-risk human papillomavirus (hrHPV)-positive women ≥25 years of age and a random subset of those ≥25 years of age who were negative by both hrHPV testing and cytology. Sociodemographics, risk factors for cervical disease, and prevalence of cervical intraepithelial neoplasia (CIN) were similar across the laboratories. There were considerable differences among the laboratories both in overall cytological abnormal rates, ranging from 3.8 to 9.9%, and in sensitivity of cytology to detect CIN grade 2 or worse (CIN2+), from 42.0 to 73.0%. In contrast, the hrHPV positivity rate varied only from 10.9 to 13.4%, and the sensitivity of hrHPV testing from 88.2 to 90.1%. These observations suggest that hrHPV testing without cytology should be considered as the initial method for cervical cancer screening. © 2013 UICC.

  11. Liquid-based versus conventional cytology of oral brush biopsies: a split-sample pilot study.

    Science.gov (United States)

    Remmerbach, T W; Pomjanski, N; Bauer, U; Neumann, H

    2017-01-11

    The aim of this prospective split sample study was to evaluate the applicability of liquid-based cytology (LBC) of oral brush biopsies for detection of oral cancer. Two different preparation techniques were investigated: the conventional transfer procedure to glass slides and the LBC preparation method. The obtainments of epithelial cells were performed five times with a nylon brush and transferred onto five glass slides. Additionally, the brushes, which were normally discarded, were stored in a fixative solution. Conventional slides and respective thin layers from a total of 113 cases were reviewed with both techniques. Thin layers showed excellent morphology on a clear background, which allowed an accurate diagnosis. In contrast, the conventional glass slides showed significantly more blood contamination and cell overlapping. The sensitivity of conventional cytological diagnosis was 96.3%, the specificity archived 90.6%, the positive predictive value was 96.3% and the negative predictive value scored 90.6%. The sensitivity of the cytological diagnosis using thin layers archived 97.5%, the specificity was 68.8%, the positive predictive value revealed 88.76% and negative predictive value was 91.7%. Our findings indicate that in oral cytology, LBC may replace other types of wet-fixed preparations using the full amount of collected cells, resulting in enhanced specimen quality archiving comparable values of diagnostic accuracy. LBC facilitates the cell collection due to simpler handling and less transfer errors by dentists and may improve the overall diagnostic accuracy of oral brush biopsies in future.

  12. Liquid-based cytology test use by office-based physicians: United States, 2006-2007.

    Science.gov (United States)

    Hing, Esther; Saraiya, Mona; Roland, Katherine B

    2011-06-01

    In the United States, liquid-based cytology (LBC) has become a common screening method for cervical cancer. However, the extent of LBC use, and how it varies by patient and practice characteristics, is unknown. This report describes the ordering and provision of Papanicolaou (Pap) tests, with a major focus on the extent to which LBC has supplanted conventional cytology. The type of Pap test is examined for visits made to primary care physicians in 2006-2007 by females aged 15-64. Estimates of Pap test cytology use (both LBC and conventional) are based on combined data from the 2006-2007 National Ambulatory Medical Care Survey (NAMCS), an annual nationally representative survey of visits to nonfederal office-based physicians in the United States, as well as on information reported by sample physicians in Cervical Cancer Screening Supplements fielded as part of NAMCS during the same years. In 2006-2007, LBC was used in approximately 75% of Pap tests for which the type of cytology was known. LBC was less likely to be used for Medicare patients than for privately insured patients, although LBC use did not vary significantly according to the other patient or practice characteristics examined. The high percentage of LBC use by office-based physicians in 2006-2007 confirms the widespread use of this screening method among primary care providers, as has been reported in the literature.

  13. Multi-phase extraction of glycoraphanin from broccoli using aminium ionic liquid-based silica.

    Science.gov (United States)

    Tian, Minglei; Bi, Wentao; Row, Kyung Ho

    2013-01-01

    Glucosinolates, a class of phytochemicals found in broccoli, have attracted recent interest due to the potential health benefits associated with their dietary intake. Glucoraphanin, the most common glucosinolate in broccoli can be converted to a known cancer chemopreventive agent. Multi-phase extraction in solid-phase extraction cartridges was developed to simultaneously extract and separate this compound. Multi-phase extraction with functionalised ionic liquid-based silica as a sorbent was used to simultaneously extract and separate glucoraphanin from broccoli. The sorbent and broccoli sample were packed into a single cartridge, and a fixed volume of water was then used to extract and remove the target compound from the sample to the sorbent over 15 repetitions. The sorbent was then washed with n-hexane to remove any interference and the target compound was eluted with water-1% acetic acid (vol.). Under the optimised condition, 0.038 mg/g of glucoraphanin was obtained by multi-phase extraction with 0.2 g of sorbent. The adsorption isotherm allowed investigation of the interactions between the sorbent and target compound and provided evidence for the accuracy of this method. The low deviation error, small amount of solvents required, highly selective separation and stability of the method justify further research. Copyright © 2012 John Wiley & Sons, Ltd.

  14. Ionic liquids based microwave-assisted extraction of lichen compounds with quantitative spectrophotodensitometry analysis.

    Science.gov (United States)

    Bonny, Sarah; Paquin, Ludovic; Carrié, Daniel; Boustie, Joël; Tomasi, Sophie

    2011-11-30

    Ionic liquids based extraction method has been applied to the effective extraction of norstictic acid, a common depsidone isolated from Pertusaria pseudocorallina, a crustose lichen. Five 1-alkyl-3-methylimidazolium ionic liquids (ILs) differing in composition of alkyl chain and anion were investigated for extraction efficiency. The extraction amount of norstictic acid was determined after recovery on HPTLC with a spectrophotodensitometer. The proposed approaches (IL-MAE and IL-heat extraction (IL-HE)) have been evaluated in comparison with usual solvents such as tetrahydrofuran in heat-reflux extraction and microwave-assisted extraction (MAE). The results indicated that both the characteristics of the alkyl chain and anion influenced the extraction of polyphenolic compounds. The sulfate-based ILs [C(1)mim][MSO(4)] and [C(2)mim][ESO(4)] presented the best extraction efficiency of norstictic acid. The reduction of the extraction times between HE and MAE (2 h-5 min) and a non-negligible ratio of norstictic acid in total extract (28%) supports the suitability of the proposed method. This approach was successfully applied to obtain additional compounds from other crustose lichens (Pertusaria amara and Ochrolechia parella).

  15. Ionic liquids based simultaneous ultrasonic and microwave assisted extraction of phenolic compounds from burdock leaves.

    Science.gov (United States)

    Lou, Zaixiang; Wang, Hongxin; Zhu, Song; Chen, Shangwei; Zhang, Ming; Wang, Zhouping

    2012-02-24

    The ionic liquids based simultaneous ultrasonic and microwave assisted extraction (IL-UMAE) technique was first proposed and applied to isolate compounds. The ionic liquids comprising a range of four anions, five 1-alkyl-3-methylimidazolium derivatives were designed and prepared. The results suggested that varying the anion and cation both had apparent effects on the extraction of phenolics. The results also showed that irradiation power, time and solid-liquid ratio significantly affected the yields. The yields of caffeic acid and quercetin obtained by IL-UMAE were higher than those by regular UMAE. Compared with conventional heat-reflux extraction (HRE), the proposed approach exhibited higher efficiency (8-17% enhanced) and shorter extraction time (from 5h to 30s). The results indicated ILUMAE to be a fast and efficient extraction technique. Moreover, the proposed method was validated by the reproducibility and recovery experiments. The ILUMAE method provided good recoveries (from 96.1% to 105.3%) with RSD lower than 5.2%, which indicated that the proposed method was credible. Based on the designable nature of ionic liquids, and the rapid and highly efficient performance of the proposed approach, ILUMAE provided a new alternative for preparation of various useful substances from solid samples.

  16. Improved extraction of fluoroquinolones with recyclable ionic-liquid-based aqueous biphasic systems.

    Science.gov (United States)

    Almeida, Hugo F D; Freire, Mara G; Marrucho, Isabel M

    2016-05-07

    In the past few years, the improvement of advanced analytical tools allowed to confirm the presence of trace amounts of metabolized and unchanged active pharmaceutical ingredients (APIs) in wastewater treatment plants (WWTPs) as well as in freshwater surfaces. It is known that the continuous contact with APIs, even at very low concentrations (ng L(-1)-μg L(-1)), leads to serious human health problems. In this context, this work shows the feasibility of using ionic-liquid-based aqueous biphasic systems (IL-based ABS) in the extraction of quinolones present in aqueous media. In particular, ABS composed of imidazolium- and phosphonium-based ILs and aluminium-based salts (already used in water treatment plants) were evaluated in one-step extractions of six fluoroquinolones (FQs), namely ciprofloxacin, enrofloxacin, moxifloxacin, norfloxacin, ofloxacin and sarafloxacin, and extraction efficiencies up to 98% were obtained. Despite the large interest devoted to IL-based ABS as extractive systems of outstanding performance, their recyclability/reusability has seldomly been studied. An efficient extraction/cleaning process of the IL-rich phase is here proposed by FQs induced precipitation. The recycling of the IL and its further reuse without losses in the ABS extractive performance for FQs were established, as confirmed by the four consecutive removal/extraction cycles evaluated. This novel recycling strategy supports IL-based ABS as sustainable and cost-efficient extraction platforms.

  17. Application of ionic liquids based enzyme-assisted extraction of chlorogenic acid from Eucommia ulmoides leaves.

    Science.gov (United States)

    Liu, Tingting; Sui, Xiaoyu; Li, Li; Zhang, Jie; Liang, Xin; Li, Wenjing; Zhang, Honglian; Fu, Shuang

    2016-01-15

    A new approach for ionic liquid based enzyme-assisted extraction (ILEAE) of chlorogenic acid (CGA) from Eucommia ulmoides is presented in which enzyme pretreatment was used in ionic liquids aqueous media to enhance extraction yield. For this purpose, the solubility of CGA and the activity of cellulase were investigated in eight 1-alkyl-3-methylimidazolium ionic liquids. Cellulase in 0.5 M [C6mim]Br aqueous solution was found to provide better performance in extraction. The factors of ILEAE procedures including extraction time, extraction phase pH, extraction temperatures and enzyme concentrations were investigated. Moreover, the novel developed approach offered advantages in term of yield and efficiency compared with other conventional extraction techniques. Scanning electronic microscopy of plant samples indicated that cellulase treated cell wall in ionic liquid solution was subjected to extract, which led to more efficient extraction by reducing mass transfer barrier. The proposed ILEAE method would develope a continuous process for enzyme-assisted extraction including enzyme incubation and solvent extraction process. In this research, we propose a novel view for enzyme-assisted extraction of plant active component, besides concentrating on enzyme facilitated cell wall degradation, focusing on improvement of bad permeability of ionic liquids solutions.

  18. Ionic liquids based simultaneous ultrasonic and microwave assisted extraction of phenolic compounds from burdock leaves

    Energy Technology Data Exchange (ETDEWEB)

    Lou Zaixiang, E-mail: louzaixiang@126.com [State Key Laboratory of Food Science and Technology, School of Food Science and Technology, Jiangnan University, Wuxi 214122 (China); Wang Hongxin, E-mail: whx200720082009@yahoo.cn [State Key Laboratory of Food Science and Technology, School of Food Science and Technology, Jiangnan University, Wuxi 214122 (China); Zhu Song; Chen Shangwei; Zhang Ming; Wang Zhouping [State Key Laboratory of Food Science and Technology, School of Food Science and Technology, Jiangnan University, Wuxi 214122 (China)

    2012-02-24

    The ionic liquids based simultaneous ultrasonic and microwave assisted extraction (IL-UMAE) technique was first proposed and applied to isolate compounds. The ionic liquids comprising a range of four anions, five 1-alkyl-3-methylimidazolium derivatives were designed and prepared. The results suggested that varying the anion and cation both had apparent effects on the extraction of phenolics. The results also showed that irradiation power, time and solid-liquid ratio significantly affected the yields. The yields of caffeic acid and quercetin obtained by IL-UMAE were higher than those by regular UMAE. Compared with conventional heat-reflux extraction (HRE), the proposed approach exhibited higher efficiency (8-17% enhanced) and shorter extraction time (from 5 h to 30 s). The results indicated ILUMAE to be a fast and efficient extraction technique. Moreover, the proposed method was validated by the reproducibility and recovery experiments. The ILUMAE method provided good recoveries (from 96.1% to 105.3%) with RSD lower than 5.2%, which indicated that the proposed method was credible. Based on the designable nature of ionic liquids, and the rapid and highly efficient performance of the proposed approach, ILUMAE provided a new alternative for preparation of various useful substances from solid samples.

  19. Application of Film-forming Additives for Ionic Liquid Based Electrolyte

    Institute of Scientific and Technical Information of China (English)

    孙敏倩; 胡志强; 蔡迎军; 董陶; 吕兴梅

    2012-01-01

    N-methyl-N-propylpiperidinium bis(trifluoromethanesulfonyl)imide was synthesized for the application in ionic liquid based electrolytes in lithium ion battery,10% vinylene carbonate (VC) and 10% 1,3-propane sultone (PS) were added to the electrolyte system respectively as additives to improve the property of solid electrolyte interface and cyclic performance.The results of cyclic voltammetry showed that homogenous and compact solid electrolyte interface film formed on graphite electrode which was detected by observing the morphology of cycled graphite anode,Charging and discharging performance of LiFePO4/Li half cell was tested in the electrolyte with or without additives.The initial specific discharging capacities were increased to 129.4 and 123.0 mA·h/g by the addition of VC and PS,respectively,compared with that of additive-free electrolyte.The discharging retentions were 88.9% and 84.6% in electrolyte containing VC and PS after 10 cycles.

  20. Solid-phase microextraction for bioconcentration studies according to OECD TG 305

    Energy Technology Data Exchange (ETDEWEB)

    Duering, Rolf-Alexander; Boehm, Leonard [Land Use and Nutrition (IFZ) Justus Liebig University Giessen, Institute of Soil Science and Soil Conservation, Research Centre for BioSystems, Giessen (Germany); Schlechtriem, Christian [Fraunhofer Institute for Molecular Biology and Applied Ecology (IME), Schmallenberg (Germany)

    2012-12-15

    An important aim of the European Community Regulation on chemicals and their safe use is the identification of (very) persistent, (very) bioaccumulative, and toxic substances. In other regulatory chemical safety assessments (pharmaceuticals, biocides, pesticides), the identification of such (very) persistent, (very) bioaccumulative, and toxic substances is of increasing importance. Solid-phase microextraction is especially capable of extracting total water concentrations as well as the freely dissolved fraction of analytes in the water phase, which is available for bioconcentration in fish. However, although already well established in environmental analyses to determine and quantify analytes mainly in aqueous matrices, solid-phase microextraction is still a rather unusual method in regulatory ecotoxicological research. Here, the potential benefits and drawbacks of solid-phase microextraction are discussed as an analytical routine approach for aquatic bioconcentration studies according to OECD TG 305, with a special focus on the testing of hydrophobic organic compounds characterized by log K{sub OW}> 5. (orig.)

  1. Dispersive liquid-liquid microextraction in food analysis. A critical review.

    Science.gov (United States)

    Viñas, Pilar; Campillo, Natalia; López-García, Ignacio; Hernández-Córdoba, Manuel

    2014-03-01

    An extensive critical evaluation of the application of dispersive liquid-liquid microextraction (DLLME) combined with chromatographic and atomic-spectroscopic methods for the determination of organic and inorganic compounds is presented. The review emphasizes the procedures used for the prior treatment of food samples, which are very different from the DLLME procedures generally proposed for water samples. The main contribution of this work in the field of DLLME reviews is its critical review of the abundant literature showing the increasing interest and practical advantages of using DLLME and closely related microextraction techniques for food analysis.

  2. Comparison of conventional Papanicolaou smear and SurePath® liquid-based cytology in the Copenhagen population screening programme for cervical cancer

    DEFF Research Database (Denmark)

    Kirschner, Benny; Simonsen, Kåre; Junge, Jette

    2006-01-01

    OBJECTIVE: To compare diagnostic performance of conventional Papanicolaou smear with SurePath liquid-based cytology in a population screening programme. METHODS: A retrospective comparison was performed on data from two 18-month periods of the screening programme for cervical cancer...... in the municipality of Copenhagen with conventional Papanicolaou technique (n = 82,116) and liquid-based cytology (n = 84,414). RESULTS: After the conversion to liquid-based cytology the percentage of unsatisfactory samples decreased from 2.3% to 0.3% (P ...-based technique. CONCLUSIONS: This study showed the number of unsatisfactory samples to be significantly reduced with the liquid-based technique. The data suggest that there is an increased detection rate of cervical precancerous lesions with liquid-based cytology, but the number of false positive tests is still...

  3. Comparison of conventional Papanicolaou smear and SurePath® liquid-based cytology in the Copenhagen population screening programme for cervical cancer

    DEFF Research Database (Denmark)

    Kirschner, Benny; Simonsen, Kåre; Junge, Jette

    2006-01-01

    OBJECTIVE: To compare diagnostic performance of conventional Papanicolaou smear with SurePath liquid-based cytology in a population screening programme. METHODS: A retrospective comparison was performed on data from two 18-month periods of the screening programme for cervical cancer...... in the municipality of Copenhagen with conventional Papanicolaou technique (n = 82,116) and liquid-based cytology (n = 84,414). RESULTS: After the conversion to liquid-based cytology the percentage of unsatisfactory samples decreased from 2.3% to 0.3% (P ... technique. CONCLUSIONS: This study showed the number of unsatisfactory samples to be significantly reduced with the liquid-based technique. The data suggest that there is an increased detection rate of cervical precancerous lesions with liquid-based cytology, but the number of false positive tests is still...

  4. Recent development and applications of dispersive liquid-liquid microextraction.

    Science.gov (United States)

    Yan, Hongyuan; Wang, Hui

    2013-06-21

    Dispersive liquid-liquid microextraction (DLLME) is a modern sample pretreatment technique that is regarded as consilient with the current trends of modern analytical chemistry. DLLME is simple, inexpensive, environmentally friendly, and could offer high enrichment factors from a wide gap between acceptor and donor phases. As a consequence, DLLME has attracted considerable attention from researchers and, based on the numerous publications concerning DLLME, has been generally accepted in separation science since the technique's invention in 2006. However, several innate weaknesses of DLLME, which restrict the technique's use in certain fields, have led to various attempts or suggestions to improve this technique. The present review focuses on the recent advances made in DLLME; the selected papers that are discussed in this work represent modifications that fall into three main categories (exploration of new extraction solvents, disperser solvents and combination with other techniques). The recent applications of DLLME in environmental, food and biological samples are also summarised, covering almost all of the publications related to the technology from the beginning. In addition, the feasibility of future trends of DLLME is discussed.

  5. Evolution of dispersive liquid-liquid microextraction method.

    Science.gov (United States)

    Rezaee, Mohammad; Yamini, Yadollah; Faraji, Mohammad

    2010-04-16

    Dispersive liquid-liquid microextraction (DLLME) has become a very popular environmentally benign sample-preparation technique, because it is fast, inexpensive, easy to operate with a high enrichment factor and consumes low volume of organic solvent. DLLME is a modified solvent extraction method in which acceptor-to-donor phase ratio is greatly reduced compared with other methods. In this review, in order to encourage further development of DLLME, its combination with different analytical techniques such as gas chromatography (GC), high-performance liquid chromatography (HPLC), inductively coupled plasma-optical emission spectrometry (ICP-OES) and electrothermal atomic absorption spectrometry (ET AAS) will be discussed. Also, its applications in conjunction with different extraction techniques such as solid-phase extraction (SPE), solidification of floating organic drop (SFO) and supercritical fluid extraction (SFE) are summarized. This review focuses on the extra steps in sample preparation for application of DLLME in different matrixes such as food, biological fluids and solid samples. Further, the recent developments in DLLME are presented. DLLME does have some limitations, which will also be discussed in detail. Finally, an outlook on the future of the technique will be given.

  6. Carbon monolith: preparation, characterization and application as microextraction fiber.

    Science.gov (United States)

    Shi, Zhi-Guo; Chen, Fei; Xing, Jun; Feng, Yu-Qi

    2009-07-10

    A carbon monolith was synthesized via a polymerization-carbonization method, styrene and divinylbenzene being adopted as precursors and dodecanol as a porogen during polymerization. The resultant monolith had bimodal porous substructure, narrowly distributed nano skeleton pores and uniform textural pores or throughpores. The carbon monolith was directly used as an extracting fiber, taking place of the coated silica fibers in commercially available solid-phase microextraction device, for the extraction of phenols followed by gas chromatography-mass spectrometry. Under the studied conditions, the calibration curves were linear from 0.5 to 50 ng mL(-1) for phenol, o-nitrophenol, 2,4-dichlorophenol and p-chlorophenol. The limits of detection were between 0.04 and 0.43 ng mL(-1). The recoveries of the phenols spiked in real water samples at 10 ng mL(-1) were between 85% and 98% with the relative standard deviations below 10%. Compared with the commercial coated ones (e.g. PDMS, CW/DVB and DVB/CAR/PDMS), the carbon monolith-based fiber had advantages of faster extraction equilibrium and higher extraction capacity due to the superior pore connectivity and pore openness resulting from its bimodal porous substructure.

  7. Ionic liquids in solid-phase microextraction: a review.

    Science.gov (United States)

    Ho, Tien D; Canestraro, Anthony J; Anderson, Jared L

    2011-06-10

    Solid-phase microextraction (SPME) has undergone a surge in popularity within the field of analytical chemistry in the past two decades since its introduction. Owing to its nature of extraction, SPME has become widely known as a quick and cost-effective sample preparation technique. Although SPME has demonstrated extraordinary versatility in sampling capabilities, the technique continues to experience a tremendous growth in innovation. Presently, increasing efforts have been directed towards the engineering of novel sorbent material in order to expand the applicability of SPME for a wider range of analytes and matrices. This review highlights the application of ionic liquids (ILs) and polymeric ionic liquids (PILs) as innovative sorbent materials for SPME. Characterized by their unique physico-chemical properties, these compounds can be structurally-designed to selectively extract target analytes based on unique molecular interactions. To examine the advantages of IL and PIL-based sorbent coatings in SPME, the field is reviewed by gathering available experimental data and exploring the sensitivity, linear calibration range, as well as detection limits for a variety of target analytes in the methods that have been developed.

  8. Solid-phase microextraction and the human fecal VOC metabolome.

    Directory of Open Access Journals (Sweden)

    Emma Dixon

    Full Text Available The diagnostic potential and health implications of volatile organic compounds (VOCs present in human feces has begun to receive considerable attention. Headspace solid-phase microextraction (SPME has greatly facilitated the isolation and analysis of VOCs from human feces. Pioneering human fecal VOC metabolomic investigations have utilized a single SPME fiber type for analyte extraction and analysis. However, we hypothesized that the multifarious nature of metabolites present in human feces dictates the use of several diverse SPME fiber coatings for more comprehensive metabolomic coverage. We report here an evaluation of eight different commercially available SPME fibers, in combination with both GC-MS and GC-FID, and identify the 50/30 µm CAR-DVB-PDMS, 85 µm CAR-PDMS, 65 µm DVB-PDMS, 7 µm PDMS, and 60 µm PEG SPME fibers as a minimal set of fibers appropriate for human fecal VOC metabolomics, collectively isolating approximately 90% of the total metabolites obtained when using all eight fibers. We also evaluate the effect of extraction duration on metabolite isolation and illustrate that ex vivo enteric microbial fermentation has no effect on metabolite composition during prolonged extractions if the SPME is performed as described herein.

  9. Chemically modified cellulose paper as a thin film microextraction phase.

    Science.gov (United States)

    Saraji, Mohammad; Farajmand, Bahman

    2013-11-01

    In this paper, chemically modified cellulose paper was introduced as a novel extracting phase for thin film microextraction (TFME). Different reagents (Octadecyltrichlorosilane, diphenyldichlorosilane, cyclohexyl isocyanate and phenyl isocyanate) were used to modify the cellulose papers. The modified papers were evaluated as a sorbent for the extraction of some synthetic and natural estrogenic hormones (17α-ethynylestradiol, estriol and estradiol) from aqueous samples. Liquid chromatography-fluorescence detection was used for the quantification of the extracted compounds. The cellulose paper modified with phenyl isocyanate showed the best affinity to the target compounds. TEME parameters such as desorption condition, shaking rate, sample ionic strength and extraction time were investigated and optimized. Limit of detections were between 0.05 and 0.23μgL(-1) and relative standard deviations were less than 11.1% under the optimized condition. The calibration curves were obtained in the range of 0.2-100μgL(-1) with a good linearity (r(2)>0.9935). Wastewater, human urine, pool and river water samples were studied as real samples for the evaluation of the method. Relative recoveries were found to be between 75% and 101%.

  10. Headspace solid-phase microextraction for wine volatile analysis.

    Science.gov (United States)

    Azzi-Achkouty, Samar; Estephan, Nathalie; Ouaini, Naïm; Rutledge, Douglas N

    2017-07-03

    The most commonly used technique to prepare samples for the analysis of wine volatile is the headspace solid-phase microextraction (HS-SPME). This method has gained popularity in last few years, as it is a unique solventless preparation technique. In this paper, a summary of recently published studies using HS-SPME for the analysis of wine aromas, with special emphasis on the method developed, has been compiled. Several papers are discussed in detail, mainly with respect to the SPME conditions used. A brief summary of the reviews related to HS-SPME analysis is given and discussed. Several parameters affecting the HS-SPME, such as the salt concentration and the agitation conditions, are used in the same way as used in several papers. The HS-SPME extraction proved to be sufficiently sensitive to satisfy legislative requirements related to low detection and quantification limits as well as method accuracy and precision requirements. However, in order to achieve the best performance and precision, the protocol needs to be optimized for each case. The effect of different parameters must be well characterized to ensure correct extraction and desorption to ensure the transfer of extracted compounds into the analytical system. The operating parameters, such as time, temperature, and agitation, must then be kept constant for all the samples.

  11. Dynamic headspace liquid-phase microextraction of alcohols.

    Science.gov (United States)

    Saraji, Mohammad

    2005-01-07

    A method was developed using dynamic headspace liquid-phase microextraction and gas chromatography-mass spectrometry for extraction and determination of 9 alcohols from water samples. Four different solvents, hexyl acetate, n-octanol, o-xylene and n-decane were studied as extractants. The analytes were extracted using 0.8 microl of n-octanol from the headspace of a 2 ml sample solution. The effect of sampling volume, solvent volume, sample temperature, syringe plunger withdrawal rate and ionic strength of the solution on the extraction performance were studied. A semiautomated system including a variable speed stirring motor was used to ensure a uniform movement of syringe plunger through the barrel. The method provided a fairly good precision for all compounds (5.5-9.3%), except methanol (16.4%). Detection limits were found to be between 1 and 97 microg/l within an extraction time of approximately 9.5 min under GC-MS in full scan mode.

  12. Role of Liquid-based Cytology and Cell Block in the Diagnosis of Endometrial Lesions

    Institute of Scientific and Technical Information of China (English)

    Hui Zhang; Jia Wen; Pi-Li Xu; Rui Chen; Xi Yang; Lian-Er Zhou; Ping Jiang

    2016-01-01

    Background:Liquid-based cytology (LBC) offers an altemative method to biopsy in screening endometrial cancer.Cell block (CB),prepared by collecting residual cytological specimen,represents a novel method to supplement the diagnosis of endometrial cytology.This study aimed to compare the specimen adequacy and diagnostic accuracy of LBC and CB in the diagnosis of endometrial lesions.Methods:A total of 198 women with high risks of endometrial carcinoma (EC) from May 2014 to April 2015 were enrolled in this study.The cytological specimens were collected by the endometrial sampler (SAP-1) followed by histopathologic evaluation of dilatation and curettage or biopsy guided by hysteroscopy.The residual cytological specimens were processed into paraffin-embedded CB after LBC preparation.Diagnostic accuracies of LBC and CB for detecting endometrial lesions were correlated with histological diagnoses.Chi-square test was used to compare the specimen adequacies of LBC and CB.Results:The specimen inadequate rate of CB was significantly higher than that of LBC (22.2% versus 7.1%,P < 0.01).There were 144 cases with adequate specimens for LBC and CB preparation.Among them,29 cases were atypical endometrial hyperplasia (11 cases) or carcinoma (18 cases) confirmed by histology evaluation.Taking atypical hyperplasia and carcinoma as positive,the diagnostic accuracy of CB was 95.1% while it was 93.8% in LBC.When combined LBC with CB,the diagnostic accuracy was improved to 95.8%,with a sensitivity of 89.7% and specificity of 97.4%.Conclusions:CB is a feasible and reproducible adjuvant method for screening endometrial lesions.A combination of CB and LBC can improve the diagnostic accuracy of endometrial lesions.

  13. DNA methylation analysis in liquid-based cytology for cervical cancer screening.

    Science.gov (United States)

    Apostolidou, Sophia; Hadwin, Richard; Burnell, Matthew; Jones, Allison; Baff, Donna; Pyndiah, Nitisha; Mould, Tim; Jacobs, Ian J; Beddows, Simon; Kocjan, Gabrijela; Widschwendter, Martin

    2009-12-15

    Cervical cancer is the second most common type of cancer in women worldwide. Preinvasive disease can be detected by cervical cytology. All currently available cytology technologies rely on the visual analysis of exfoliated cells from the uterine cervix. Improvement of conventional cytological screening has been proposed by the introduction of molecular-based markers applied to liquid-based cytology (LBC), the suspension of cells collected from the cervix. DNA methylation changes occur very early in carcinogenesis and identification of appropriate DNA methylation markers in such samples should be able to distinguish high-grade squamous intraepithelial lesions (HSIL) from nonspecific cytology changes and the normal cervix. To address this potential, we have undertaken a proof-of-principle study of methylation status of LBC samples from HSIL cytology cases compared against matched normal controls. Using quantitative methylation-specific PCR on 28 genes, we found SOX1, HOXA11 and CADM1 to significantly discriminate between the groups analyzed (p<0.01). Area under the receiver operating characteristic (ROC) curve (AUC) demonstrated that methylation of SOX1, HOXA11 and CADM1 could discriminate between HSIL cases and controls with high sensitivity and specificity (AUC 0.910, 0.844 and 0.760, respectively). The results were further validated in an independent set. This proof-of-principle study is the first to validate the results in an independent case/control set and presents HOXA11, a gene that is important for cervical development, as a potentially useful DNA marker in LBC samples. Further assessment of these preliminary estimates will need to be performed in a larger cohort to confirm clinical utility.

  14. The advantages of incorporating liquid-based cytology (TACAS™) in mass screening for cervical cancer.

    Science.gov (United States)

    Yokoyama, Yoshihito; Futagami, Masayuki; Watanabe, Jun; Sakuraba, Atsushi; Nagasawa, Kazuma; Maruyama, Hidetoshi; Sato, Shigemi

    2016-04-01

    We incorporated liquid-based cytology (LBC) in population-based screening for cervical cancer. The usefulness of using LBC in mass screening for cervical cancer was examined. From 2009 to 2014, 157,061 individuals underwent mass screening for cervical cancer in Aomori Prefecture. From 2009 to 2011, cells were collected from 82,218 individuals and the specimens were conventionally prepared (CP). From 2012 to 2014, cells were collected from 74,843 individuals and the specimens were prepared using LBC (TACAS™). Cytology results for the 2 sets of specimens were compared and differences in cytologic features were examined. ASC-US and more severe lesions were detected at a rate of 1.13 % by CP and 1.44 % by LBC, so LBC had a 1.3-fold higher rate of detection. LBC had a 1.6-fold higher rate of LSIL detection and a 1.2-fold higher rate of HSIL detection. CP detected cancer in 20 cases at a rate of 0.024 % while LBC detected cancer in 18 cases at a rate of 0.024 %. Cytodiagnosis of the 18 cases of SCC that LBC identified revealed that 7 were SCC, 8 were HSIL, and 3 were ASC-H. Atypical cells tended to be smaller with TACAS™. LBC reduced the time needed for microscopic examination of a single specimen by 42 % in comparison to CP. LBC using TACAS™ allowed the detection of slight lesions and slight changes in cells. LBC can lessen the burden on medical personnel and may lead to improved accuracy.

  15. Cervical screening by visual inspection, HPV testing, liquid-based and conventional cytology in Amazonian Peru.

    Science.gov (United States)

    Almonte, Maribel; Ferreccio, Catterina; Winkler, Jennifer L; Cuzick, Jack; Tsu, Vivien; Robles, Sylvia; Takahashi, Rina; Sasieni, Peter

    2007-08-15

    Cervical cancer is an important public health problem in many developing countries, where cytology screening has been ineffective. We compared four tests to identify the most appropriate for screening in countries with limited resources. Nineteen midwives screened 5,435 women with visual inspection (VIA) and collected cervical samples for HPV testing, liquid-based cytology (LBC) and conventional cytology (CC). If VIA was positive, a doctor performed magnified VIA. CC was read locally, LBC was read in Lima and HPV testing was done in London. Women with a positive screening test were offered colposcopy or cryotherapy (with biopsy). Inadequacy rates were 5% and 11% for LBC and CC respectively, and less than 0.1% for VIA and HPV. One thousand eight hundred eighty-one women (84% of 2,236) accepted colposcopy/cryotherapy: 79 had carcinoma in situ or cancer (CIS+), 27 had severe- and 42 moderate-dysplasia on histology. We estimated a further 6.5 cases of CIS+ in women without a biopsy. Sensitivity for CIS+ (specificity for less than moderate dysplasia) was 41.2% (76.7%) for VIA, 95.8% (89.3%) for HPV, 80.3% (83.7%) for LBC, and 42.5% (98.7%) for CC. Sensitivities for moderate dysplasia or worse were better for VIA (54.9%) and less favourable for HPV and cytology. In this setting, VIA and CC missed the majority of high-grade disease. Overall, HPV testing performed best. VIA gives immediate results, but will require investment in regular training and supervision. Further work is needed to determine whether screened-positive women should all be treated or triaged with a more specific test.

  16. Utility of liquid-based cytology in endometrial pathology: diagnosis of endometrial carcinoma.

    Science.gov (United States)

    Norimatsu, Y; Kouda, H; Kobayashi, T K; Shimizu, K; Yanoh, K; Tsukayama, C; Miyake, Y; Ohno, E

    2009-12-01

    The purpose of this study was to examine the utility of SurePath-liquid-based cytology (LBC) compared to conventional cytological preparations (CCP) in the identification of endometrial carcinoma. During a 13-month period, direct endometrial samples were collected from 120 patients using the Uterobrush. The material comprised 30 cases each of endometrial carcinoma, proliferative endometrium, secretory endometrium and atrophic endometrium. The following points were investigated:(i) the frequency of cell clumps in endometrial carcinoma; (ii) the area of cell nuclei; (iii) overlapping nuclei. (i) Comparison of the frequency of cell clumps with irregular protrusion pattern and papillo-tubular pattern showed no statistically significant difference in either type of cell clump between CCP and LBC. (ii) Comparison of the nuclear area of cells showed a sequential decrease from endometrial carcinoma to secretory endometrium, to proliferative endometrium and to atrophic endometrium, which was significant in CCP and LBC. (iii) Nuclear area was significantly lower with LBC compared with CCP in endometrial carcinoma, secretory endometrium and proliferative endometrium but not atrophic endometrium. (iv) Comparison of the degree of overlapping nuclei showed a sequential decrease from endometrial carcinoma to proliferative endometrium, to secretory endometrium and to atrophic endometrium, which was significant in both CCP and LBC. (v) Comparison of the degree of overlapping nuclei between CCP and LBC showed no significant difference for normal types of endometrium, but LBC had significantly higher values (P cytological features of malignancy and have not considered atypical hyperplasia, we believe that this method may be a useful tool in the diagnosis of endometrial cytology.

  17. Is a liquid-based cytology more sensitive than a conventional Pap smear?

    Science.gov (United States)

    Sigurdsson, K

    2013-08-01

    The comparative sensitivity of liquid-based cytology (LBC) test and conventional Papanicolaou (Pap) smears is controversial. This study analyses the distribution of cytology, histology, colposcopy and large loop excision of the transformation zone among women screened in Iceland with LBC at the Cancer Detection Clinic in Reykjavik and with a conventional Pap smear outside the Detection Clinic in 2007-2011. The study material included 42 654 LBC tests from 20 439 women and 103 909 Pap smears from 61 574 women. The period 2000-2004 is used to correct for potential bias as a result of unequal distribution of the studied parameters between the study sites before the introduction of LBC. The observed results indicated that women screened with an LBC sample had significantly decreased detection rates of inadequate smears, increased detection of low-grade squamous intraepithelial lesion (LSIL)/atypical cytology and referrals to colposcopy, and an increased detection rate of cervical intraepithelial neoplasia grade 2 or worse (CIN2+) irrespective of age. LBC increased significantly the detection rates of high-grade squamous intraepithelial lesion or worse (HSIL+) cytology and CIN3+ histology only in women under 40 years of age. Taking into consideration the unequal prevalence of the studied parameters between the study sites in 2000-2004 indicated, however, that LBC only affected the rate of inadequate and low-grade cytology tests under the age of 40 years. Positive predictive values for CIN2+ were not significantly different between the tests. The study results support the view that LBC is no more sensitive than Pap smears for the detection of HSIL+ and CIN2+ irrespective of age. LBC decreased the rate of inadequate smears, but increased the rate of low-grade cytology under the age of 40 years and decreased the total rate of abnormal smears over the age of 40 years. © 2013 John Wiley & Sons Ltd.

  18. Diagnostic value of liquid-based cytology with fine needle aspiration specimens for cervical lymphadenopathy.

    Science.gov (United States)

    Bandoh, Nobuyuki; Goto, Takashi; Akahane, Toshiaki; Ohnuki, Natsumi; Yamaguchi, Tomomi; Kamada, Hajime; Harabuchi, Yasuaki; Tanaka, Shinya; Nishihara, Hiroshi

    2016-03-01

    Cervical lymphadenopathy is a symptom that is frequently seen among outpatients, and it is important to differentiate malignant lesions from reactive lymphoid hyperplasia. Fine needle aspiration (FNA) cytology has been widely used for the diagnosis of cervical lymphadenopathy. However, some limitations of the diagnostic accuracy using conventional smear (CS) cytology have been pointed out. The diagnostic value of liquid-based cytology (LBC) with FNA specimens has not yet been fully proven. Forty-two patients with cervical lymphadenopathy who underwent FNA with CS cytology from 2007 to 2011 and 123 patients who underwent FNA with LBC utilizing LBCPREP2™ from 2011 to 2015 were studied. Diagnostic values were compared between the CS and the LBC groups. Of the total 165 patients representing the combined CS and LBC groups, 81 (49.1%) were diagnosed as benign lymph node and 84 (50.9%) were malignant diseases including 37 (22.4%) of metastatic carcinoma except for thyroid carcinoma, 30 (18.2%) of metastatic thyroid carcinoma, and 17 (10.3%) of malignant lymphoma. The overall statistical values including sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of the CS were 75%, 100%, 100%, 78.9%, and 87.1%, respectively, whereas those values for LBC were 91.2%, 100%, 100%, 90.7%, and 95.3%, respectively. The sensitivity of LBC for malignant diseases tended to be higher than that of CS cytology (p = 0.081). LBC with FNA specimens from cervical lymphadenopathy is a useful and reliable method for the diagnosis of malignant diseases, especially of metastatic carcinomas, due to its increased sensitivity compared with CS cytology. © 2016 The Authors Diagnostic Cytopathology Published by Wiley Periodicals, Inc.

  19. Evaluation of RNA and DNA extraction from liquid-based cytology specimens.

    Science.gov (United States)

    Fujii, Tomomi; Asano, Aya; Shimada, Keiji; Tatsumi, Yoshihiro; Obayashi, Chiho; Konishi, Noboru

    2016-10-01

    Molecular diagnosis using DNA and RNA derived from malignant tumors and molecular biological tools such as the quantitative polymerase-chain-reaction (qPCR) is a commonly used technique in clinical pathology. In this report, we compared the qualitative extraction of RNA and DNA from cancer cells fixed using several liquid-based cytology (LBC) kits. Ten to 1,000 cells from the T24 urinary bladder cancer cell line and SKG-II cervical cancer cell line were fixed with 55% methanol and three different methanol-based LBC solutions. The mRNA levels of CD44 in T24 cells and E7 in SKG-II cells and DNA levels of p53 in T24 cells and E7 in SKG-II cells were analyzed by qPCR. mRNA and DNA extracted from T24 and/or SKG-II cells fixed with methanol-based LBC solutions were efficiently detected, but to differing degrees, by qPCR. mRNA, and DNA from cells fixed with a formaldehyde-containing fixative liquid were detected at significantly low copy numbers by qPCR. Our results demonstrate that LBC systems are powerful tools for cytopathology and immunocytochemistry applications. However, the appropriate fixative must be selected for cell preservation when a small number of LBC samples is used for molecular testing, particularly in RNA-based molecular analyses. Diagn. Cytopathol. 2016;44:833-840. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  20. A survey of vitreous cell components performed using liquid-based cytology.

    Science.gov (United States)

    Narumi, Mari; Nishitsuka, Koichi; Yamakawa, Mitsunori; Yamashita, Hidetoshi

    2015-08-01

    To confirm the efficacy of liquid-based cytology (LBC) method in the observation of vitreous cells in various vitreoretinal diseases in human. Vitreous fluid samples from 30 eyes were obtained by 23-gauge 3-port pars plana vitrectomy. After making three ports, we collected vitreous specimen from the core vitreous cavity without infusion. We divided the samples into a quiescent group and an active group based on clinical signs of inflammation. To confirm availability of LBC preparation slides for immunostaining, we also performed immunocytochemistry (ICC) for CD68, RPE65 and DEC-205 (CD205) using LBC slides of 10 cell-rich cases including retinal detachment and endophthalmitis. Using LBC method, small amounts of vitreous cells were observed efficiently. Vitreous cells were observed in inflammatory quiescent cases including macular pucker and macular hole. The number of vitreous cells increased significantly in the cases with clinically active inflammation (2297 versus 207 cells/ml, respectively, p < 0.01, Mann-Whitney U-test). The ICC results showed the presence of CD68(+) cells in all 10 cases. Large numbers of DEC-205(+) cells were observed in one case with infectious endophthalmitis. In the cases with retinal detachment, the predominant cell type was RPE65(+) . Neutrophils and lymphocytes were also observed. The LBC method makes it possible to examine vitreous specimens easily and efficiently, facilitating the expedient diagnosis of vitreoretinal diseases, and the preparation slides are available for immunocytochemistry. This study also showed that vitreoretinal disease involves the migration of various types of cells including macrophages, neutrophils, lymphocytes, RPE65(+) pigmented cells and DEC-205(+) cells. © 2015 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  1. Role of Liquid-based Cytology and Cell Block in the Diagnosis of Endometrial Lesions

    Science.gov (United States)

    Zhang, Hui; Wen, Jia; Xu, Pi-Li; Chen, Rui; Yang, Xi; Zhou, Lian-Er; Jiang, Ping; Wan, An-Xia; Liao, Qin-Ping

    2016-01-01

    Background: Liquid-based cytology (LBC) offers an alternative method to biopsy in screening endometrial cancer. Cell block (CB), prepared by collecting residual cytological specimen, represents a novel method to supplement the diagnosis of endometrial cytology. This study aimed to compare the specimen adequacy and diagnostic accuracy of LBC and CB in the diagnosis of endometrial lesions. Methods: A total of 198 women with high risks of endometrial carcinoma (EC) from May 2014 to April 2015 were enrolled in this study. The cytological specimens were collected by the endometrial sampler (SAP-1) followed by histopathologic evaluation of dilatation and curettage or biopsy guided by hysteroscopy. The residual cytological specimens were processed into paraffin-embedded CB after LBC preparation. Diagnostic accuracies of LBC and CB for detecting endometrial lesions were correlated with histological diagnoses. Chi-square test was used to compare the specimen adequacies of LBC and CB. Results: The specimen inadequate rate of CB was significantly higher than that of LBC (22.2% versus 7.1%, P < 0.01). There were 144 cases with adequate specimens for LBC and CB preparation. Among them, 29 cases were atypical endometrial hyperplasia (11 cases) or carcinoma (18 cases) confirmed by histology evaluation. Taking atypical hyperplasia and carcinoma as positive, the diagnostic accuracy of CB was 95.1% while it was 93.8% in LBC. When combined LBC with CB, the diagnostic accuracy was improved to 95.8%, with a sensitivity of 89.7% and specificity of 97.4%. Conclusions: CB is a feasible and reproducible adjuvant method for screening endometrial lesions. A combination of CB and LBC can improve the diagnostic accuracy of endometrial lesions. PMID:27270542

  2. Differentiating between benign follicular nodules and follicular neoplasms in thyroid liquid-based cytology preparations.

    Science.gov (United States)

    Suzuki, Ayana; Hirokawa, Mitsuyoshi; Higuchi, Miyoko; Takada, Nami; Yamao, Naoki; Kuma, Seiji; Miyauchi, Akira

    2016-08-01

    The cytological morphology observed in liquid-based cytology (LBC) preparations is dissimilar to that of conventional preparations. The aim of this report is to clarify the cytological differences between benign follicular nodules (BFNs) and follicular neoplasms (FNs) in LBC preparations and identify novel diagnostic criteria for LBC preparations. A retrospective review of LBC preparations from 38 BFN and 74 FN (57 follicular adenomas and 17 follicular carcinomas) cases confirmed by histological examination was conducted. LBC samples were obtained from the washout fluid in aspiration needles, fixed with CytoRich-RED(TM) , and prepared using the SurePath(TM) method. Fibrin was observed in 43.2% of FNs and in 23.7% of BFNs. The incidences of intercellular spaces, distinct outer margin, and cytoplasmic process were significantly higher in BFNs (P < 0.01, P < 0.01, and P < 0.05, respectively). Elongated microfollicles were seen in 55.4% of FNs and 10.5% of BFNs (P < 0.01). Membranous materials encircling the outer edge of the follicles were observed only in BFN cases (5.8%). There were no significant differences between follicular adenoma and carcinoma. Intercellular spaces, distinct outer margins of the follicular clusters, cytoplasmic process, and membranous materials constitute indicators of BFN in LBC preparations. Fibrin and elongated microfollicles point to FN. We believe that these findings will improve the diagnostic accuracy of thyroid LBC preparations. Diagn. Cytopathol. 2016;44:659-664. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  3. Nuclear characteristics of the endometrial cytology: liquid-based versus conventional preparation.

    Science.gov (United States)

    Norimatsu, Yoshiaki; Shigematsu, Yumie; Sakamoto, Shingo; Ohsaki, Hiroyuki; Yanoh, Kenji; Kawanishi, Namiki; Kobayashi, Tadao K

    2013-02-01

    The aim of this study was to assess the utility of liquid-based cytologic preparation (LP) compared with conventional preparation (CP) for the assessment of nuclear findings in endometrial glandular and stromal breakdown (EGBD) which may be misdiagnosed as carcinoma in EGBD cases. The material consists of cytologic smears including 20 cases of proliferative endometrium (PE), 20 cases of EGBD, and 20 cases of endometrioid adenocarcinoma grade1 (G1) for which histopathological diagnosis was obtained by endometrial curettage at the JA Suzuka General Hospital. Nuclear findings were examined in PE cells, EGBD-stromal cells, EGBD-metaplastic cells, and G1 cells, respectively. It was examined about the following items; (1) nuclear shape; (2) A long/minor axis ratio in cell nuclei; (3) an area of cell nuclei; (4) overlapping nuclei. Results are as follows: (1) nuclear shape; as for the reniform shape of EGBD-stromal cells and spindle shape of EGBD-metaplastic cells, the ratio of the LP method was a higher value than the CP method. (2) The long axis and area of cell nuclei; LP in all groups was a recognizable tendency for nuclear shrinkage. (3) The long/minor axis ratio in cell nuclei; only EGBD-metaplastic cells recognize a significant difference between CP and LP. (4) Overlapping nuclei; LP was a higher value in comparison with CP in the other groups except PE cells, and the degree of overlapping nuclei was enhanced about three times. Therefore, although a cell of LP has a shrinking tendency, (1) it is excellent that LP preserves a characteristic of nuclear shape than CP; (2) a cellular characteristic becomes clearer, because three-dimensional architecture of LP is preserved of than CP. As for the standard preparation method for endometrial cytology samples, we considered that a concrete introduction of the LP method poses no problems.

  4. Advances in the electrodeposition of aluminum from ionic liquid based electrolytes

    Science.gov (United States)

    Leadbetter, Kirt C.

    Aluminum plating is of considerable technical and economic interest because it provides an eco-friendly substitute for cadmium coatings used on many military systems. However, cadmium has been determined to be a significant environmental safety and occupational health (ESOH) hazard because of its toxicity and carcinogenic nature. Furthermore, the cost of treating and disposing of generated wastes, which often contain cyanide, is costly and is becoming prohibitive in the face of increasingly stringent regulatory standards. The non-toxic alternative aluminum is equivalent or superior in performance to cadmium. In addition, it could serve to provide an alternative to hexavalent chromium coatings used on military systems for similar reasons to that of cadmium. Aluminum is a beneficial alternative in that it demonstrates self-healing corrosion resistance in the form of a tightly-bound, impervious oxide layer. A successfully plated layer would be serviceable over a wider temperature range, 925 °F for aluminum compared to 450 oF for cadmium. In addition, an aluminum layer can be anodized to make it non-conducting and colorable. In consideration of the plating process, aluminum cannot be deposited from aqueous solutions because of its reduction potential. Therefore, nonaqueous electrolytes are required for deposition. Currently, aluminum can be electrodeposited in nonaqueous processes that use hazardous chemicals such as toluene and pyrophoric aluminum alkyls. Electrodeposition from ionic liquids provides the potential for a safer method that could be easily scaled up for industrial application. The plating process could be performed at a lower temperature and higher current density than other commercially available aluminum electrodeposition processes; thus a reduced process cost could be possible. The current ionic liquid based electrolytes are more expensive; however production on a larger scale and a long electrolyte lifetime are associated with a reduction in price

  5. Liquid-based cytology versus conventional cytology for evaluation of cervical Pap smears: Experience from the first 1000 split samples

    OpenAIRE

    Vikrant Bhar Singh; Nalini Gupta; Raje Nijhawan; Radhika Srinivasan; Vanita Suri; Arvind Rajwanshi

    2015-01-01

    Context and Aim: Screening programs using conventional cytology conventional Pap smear (CPS) have successfully reduced cervical cancer, but newer tests like liquid-based cytology (LBC) and human papillomavirus testing might enhance screening. The main aim of the present study was to assess the diagnostic accuracy of LBC versus CPS using "split samples." Materials and Methods: This was a prospective study comprising of 1000 consecutive cervical "split samples" over a period of 1 year. Split sa...

  6. Potential applications of oral brush cytology with liquid-based technology: results from a cohort of normal oral mucosa.

    Science.gov (United States)

    Kujan, Omar; Desai, Mina; Sargent, Alexandra; Bailey, Andrew; Turner, Andrew; Sloan, Philip

    2006-09-01

    Fifty healthy volunteers were studied to assess the potential applications of oral brush sampling using liquid-based cytology. Three specimens from the buccal mucosa and lateral border of tongue were collected from each subject by using cervical brushes and brooms. The brush was immersed in a preservative fluid. The sample in the preservative fluid was processed according to the manufacturer's directions (SurePath, UK). Slides were stained by the Papanicolaou method and assessed for squamous cell adequacy by the same criteria used for cervical cytology screening. Immunocytochemical staining for FHIT (Fragile Histidine Triad) was applied in liquid-based preparations following the streptavidin-biotin-peroxidase method. Human papillomavirus (HPV) detection was performed using the Hybrid Capture 2 assay (Digene) and the PCR-based Roche AMPLICOR HPV Test. LBC preparation slides showed good sample preservation, specimen adequacy and visualization of cell morphology. Interestingly, nine cases showed borderline cytological abnormalities from apparently normal oral mucosa. All cases showed good quality positive FHIT immunoreactivity staining. All studied cases were high-risk HPV negative using HC2 assay method. However, the AMPLICOR Roche Test detected four samples with positive results for high-risk HPVs. Liquid-based cytology has potential as a screening tool for oral cancer and precancer. The method may also have applications for research and practice in the field of oral cancer and precancer. However a special custom-designed oral cytobrush is required.

  7. Solid Phase Microextraction and Related Techniques for Drugs in Biological Samples

    Directory of Open Access Journals (Sweden)

    Mohammad Mahdi Moein

    2014-01-01

    Full Text Available In drug discovery and development, the quantification of drugs in biological samples is an important task for the determination of the physiological performance of the investigated drugs. After sampling, the next step in the analytical process is sample preparation. Because of the low concentration levels of drug in plasma and the variety of the metabolites, the selected extraction technique should be virtually exhaustive. Recent developments of sample handling techniques are directed, from one side, toward automatization and online coupling of sample preparation units. The primary objective of this review is to present the recent developments in microextraction sample preparation methods for analysis of drugs in biological fluids. Microextraction techniques allow for less consumption of solvent, reagents, and packing materials, and small sample volumes can be used. In this review the use of solid phase microextraction (SPME, microextraction in packed sorbent (MEPS, and stir-bar sorbtive extraction (SBSE in drug analysis will be discussed. In addition, the use of new sorbents such as monoliths and molecularly imprinted polymers will be presented.

  8. Comparison of two ultrasound-enhanced microextractions combined with HPLC for determining acaricides in water.

    Science.gov (United States)

    Peng, Bing; Yang, Xiaoling; Zhang, Jiaheng; Du, Fengpei; Zhou, Wenfeng; Gao, Haixiang; Lu, Runhua

    2013-07-01

    An ultrasound-enhanced in situ solvent formation microextraction has been developed first time and compared with ultrasound-enhanced ionic-liquid-assisted dispersive liquid-liquid microextraction for the HPLC analysis of acaricides in environmental water samples. A ionic liquid ([C8MIM][PF6]) was used as the green extraction solvent through two pathways. The experimental parameters, such as the type and volume of both of the extraction solvent disperser solvent, ultrasonication time, and salt addition, were investigated and optimized. The analytical performance using the optimized conditions proved the feasibility of the developed methods for the quantitation of trace levels of acaricides by obtaining limits of detection that range from 0.54 to 3.68 μg/L. The in situ solvent formation microextraction method possesses more positive characteristics than the ionic-liquid-assisted dispersive liquid-liquid microextraction method (except for spirodiclofen determination) when comparing the validation parameters. Both methods were successfully applied to determining acaricides in real water samples.

  9. Luminescence screening of enrofloxacin and ciprofloxacin residues in swine liver after dispersive liquid - liquid microextraction cleanup

    Science.gov (United States)

    A rapid luminescence method was developed to screen residues of enrofloxacin (ENRO) and its metabolite, ciprofloxacin (CIPRO), in swine liver. Target analytes were extracted in acetonitrile-2.5% trifluoroacetic acid-NaCl, cleaned up by dispersive liquid-liquid microextraction (DLLME), and finally de...

  10. Solid phase microextraction speciation analysis of triclosan in aqueous mediacontaining sorbing nanoparticles

    NARCIS (Netherlands)

    Zielinska, K.

    2014-01-01

    Solid phase microextraction (SPME) is applied in the speciation analysis of the hydrophobic compound triclosan in an aqueous medium containing sorbing SiO2 nanoparticles (NPs). It is found that these NPs, as well as their complexes with triclosan, partition between the bulk medium and the solid

  11. Solid phase microextraction speciation analysis of triclosan in aqueous mediacontaining sorbing nanoparticles

    NARCIS (Netherlands)

    Zielinska, K.

    2014-01-01

    Solid phase microextraction (SPME) is applied in the speciation analysis of the hydrophobic compound triclosan in an aqueous medium containing sorbing SiO2 nanoparticles (NPs). It is found that these NPs, as well as their complexes with triclosan, partition between the bulk medium and the solid phas

  12. Sol-gel microextraction phases for sample preconcentration in chromatographic analysis.

    Science.gov (United States)

    Segro, Scott S; Tran, Minh Phuong; Kesani, Sheshanka; Alhendal, Abdullah; Turner, Erica B

    2010-10-01

    Sol-gel technology provides a simple and reliable method for solid-phase microextraction (SPME) fiber preparation through in situ creation of surface-bonded organic-inorganic hybrid coatings characterized by enhanced thermal stability and solvent-resistance properties that are important for the coupling of SPME with GC and HPLC, respectively. The sol-gel coating technology has led to the development of an extensive array of sol-gel sorbent coatings for SPME. In this article, sol-gel microextraction coatings are reviewed, with particular attention on their synthesis, characterization, and applications in conjunction with GC and HPLC analyses. In addition, the development of sol-gel-coated stir bars, their inherent advantages, and applications are discussed. Next, the development and applications of sol-gel capillary microextraction (CME) in hyphenation with GC and HPLC is extensively reviewed. The newly emerging germania- and titania-based sol-gel microextraction phases look promising, especially in terms of pH and hot solvent stability. Finally, sol-gel monolithic beds for CME are reviewed. Such monolithic beds are in a position to greatly improve the extracting capabilities and enhanced sensitivity in CME.

  13. Determination of lidocaine in plasma by direct solid-phase microextraction combined with gas chromatography

    NARCIS (Netherlands)

    Koster, EHM; Wemes, C; Morsink, JB; de Jong, GJ

    2000-01-01

    Direct-immersion solid-phase microextraction (SPME) has been used to extract the local anesthetic lidocaine from human plasma. A simplified model shows the relationship between the total amount of drug in plasma and the amount of drug extracted. The model takes into account that the drug participate

  14. Solid-phase micro-extraction in bioanalysis, exemplified by lidocaine determination

    NARCIS (Netherlands)

    de Jong, GJ; Koster, EHM

    2000-01-01

    Solid-phase micro-extraction (SPME) is a never sample preparation technique that can be used for gaseous, liquid or solid samples in conjunction with GC, HPLC or CE (e.g. [1]). The use of SPME for the analysis of drugs in biofluids is also becoming popular (e.g. [2]). The principle is that a fused s

  15. Speciation analysis of aqueous nanoparticulate diclofenac complexes by solid-phase microextraction

    NARCIS (Netherlands)

    Zielinska, K.; Leeuwen, van H.P.; Thibault, S.; Town, R.M.

    2012-01-01

    The dynamic sorption of an organic compound by nanoparticles (NPs) is analyzed by solid-phase microextraction (SPME) for the example case of the pharmaceutical diclofenac in dispersions of impermeable (silica, SiO(2)) and permeable (bovine serum albumin, BSA) NPs. It is shown that only the protonate

  16. Fibers coated with molecularly imprinted polymers for solid-phase microextraction

    NARCIS (Netherlands)

    Koster, E.H M; Crescenzi, C; den Hoedt, W; Ensing, K; de Jong, G.J.

    2001-01-01

    The simplicity and flexibility of solid-phase microextraction have been combined with the selectivity of molecularly imprinted polymers (MIPs), Silica fibers were coated reproducible with a 75-mum layer of methacrylate polymer either nonimprinted or imprinted with clenbuterol to compare their extrac

  17. Dynamic speciation analysis of atrazine in aqueous latex nanoparticle dispersions using solid phase microextraction (SPME)

    NARCIS (Netherlands)

    Benhabib, K.; Town, R.M.; Leeuwen, van H.P.

    2009-01-01

    Solid phase microextraction (SPME) is applied in the dynamic speciation analysis of the pesticide atrazine in an aqueous medium containing sorbing latex nanoparticles. It is found that the overall rate of extraction of the analyte is faster than in the absence of nanoparticles and governed by the

  18. Simultaneous sampling and analysis of indoor air infested with Cimex lectularius L. (Hemiptera: Cimicidae) by solid phase microextraction, thin film microextraction and needle trap device.

    Science.gov (United States)

    Eom, In-Yong; Risticevic, Sanja; Pawliszyn, Janusz

    2012-02-24

    Air in a room infested by Cimex lectularius L. (Hemiptera: Cimicidae) was sampled simultaneously by three different sampling devices including solid phase microextraction (SPME) fiber coatings, thin film microextraction (TFME) devices, and needle trap devices (NTDs) and then analyzed by gas chromatography-mass spectrometry (GC-MS). The main focus of this study was to fully characterize indoor air by identifying compounds extracted by three different microextraction formats and, therefore, perform both the device comparison and more complete characterization of C. lectularius pheromone. The NTD technique was capable of extracting both (E)-2-hexenal and (E)-2-octenal, which were previously identified as alarm pheromones of bedbugs, and superior NTD recoveries for these two components allowed reliable identification based on mass spectral library searching and linear temperature programmed retention index (LTPRI) technique. While the use of DVB/CAR/PDMS SPME fiber coatings provided complementary sample fingerprinting and profiling results, TFME sampling devices provided discriminative extraction coverage toward highly volatile analytes. In addition to two alarm pheromones, relative abundances of all other analytes were recorded for all three devices and aligned across all examined samples, namely, highly infested area, less infested area, and control samples which were characterized by different bedbug populations. The results presented in the current study illustrate comprehensive characterization of infested indoor air samples through the use of three different non-invasive SPME formats and identification of novel components comprising C. lectularius pheromone, therefore, promising future alternatives for use of potential synthetic pheromones for detection of infestations.

  19. HPV-DNA testing and Ki-67 immunocytochemistry in liquid based cervical cytology in prostitute women

    Directory of Open Access Journals (Sweden)

    Esin ATİK

    2006-09-01

    Full Text Available HPV causes several changes in the function of host genes, and these interactions cause deregulation of the cell cycle manifested by abnormal expression of cell cycle associated proteins, such as Ki-67. The detection of Ki-67 can play a role in screening and diagnosis of HPV infection with risk of progression towards dysplasia and carcinoma. To show this relation in prostitute women, cervical cells were collected in the PapSpin Collection Fluid. A starting volume of 1000 µl for each sample, and a 200 µl cell suspension were used to prepare each sample for thin layer liquid based cytology and then they were stained by Papanicolaou method. The cytological results were classified according to the Bethesda 2001 system. From the remaining cell suspension of 800 µl, a 400 µl sample was used for HPV-DNA detection by PCR, a 50 µl alliquot was used to make thin layer preparations for immunocytochemistry. Single antigen staining was performed with Ki-67 protein. Cells were considered immunopositive if the nuclei were stained. All cells in one high power field (x400 were counted, and the fraction of immunopositive cells on the slide was calculated. This fraction was expressed as the number of positive cells per 1000 cells to facilitate comparisons of differential cell counts. HPV types 6 and 32 in the study, and HPV types 6 and 51 in the control group were detected. The mean Ki-67 values were 2.7±1.2 and 3.6±4.1 in HPV positive and negative cases respectively. There was a positive correlation only with nuclear changes and HPV positivity (x2=28.8, p<0.001. There was not any significant correlation between HPV or Ki-67 and leukocytosis. An association with HPV and contraception, smoking, and concurrent genital infection was not found. The prevalence of HPV types in different geographical locations and races may indicate different etiologies of cervical cancer. Our results suggest that Ki-67 immunocytochemistry is not useful as a surrogate marker for

  20. Capillary microextraction: A new method for sampling methamphetamine vapour.

    Science.gov (United States)

    Nair, M V; Miskelly, G M

    2016-11-01

    Clandestine laboratories pose a serious health risk to first responders, investigators, decontamination companies, and the public who may be inadvertently exposed to methamphetamine and other chemicals used in its manufacture. Therefore there is an urgent need for reliable methods to detect and measure methamphetamine at such sites. The most common method for determining methamphetamine contamination at former clandestine laboratory sites is selected surface wipe sampling, followed by analysis with gas chromatography-mass spectrometry (GC-MS). We are investigating the use of sampling for methamphetamine vapour to complement such wipe sampling. In this study, we report the use of capillary microextraction (CME) devices for sampling airborne methamphetamine, and compare their sampling efficiency with a previously reported dynamic SPME method. The CME devices consisted of PDMS-coated glass filter strips inside a glass tube. The devices were used to dynamically sample methamphetamine vapour in the range of 0.42-4.2μgm(-3), generated by a custom-built vapour dosing system, for 1-15min, and methamphetamine was analysed using a GC-MS fitted with a ChromatoProbe thermal desorption unit. The devices showed good reproducibility (RSDsampling times and peak area, which can be utilised for calibration. Under identical sampling conditions, the CME devices were approximately 30 times more sensitive than the dynamic SPME method. The CME devices could be stored for up to 3days after sampling prior to analysis. Consecutive sampling of methamphetamine and its isotopic substitute, d-9 methamphetamine showed no competitive displacement. This suggests that CME devices, pre-loaded with an internal standard, could be a feasible method for sampling airborne methamphetamine at former clandestine laboratories. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  1. Application of solid phase microextraction on dental composite resin analysis.

    Science.gov (United States)

    Wang, Ven-Shing; Chang, Ta-Yuan; Lai, Chien-Chen; Chen, San-Yue; Huang, Long-Chen; Chao, Keh-Ping

    2012-08-15

    A direct immersion solid phase microextraction (DI-SPME) method was developed for the analysis of dentin monomers in saliva. Dentine monomers, such as triethylene glycol dimethacrylate (TEGDMA), urethane dimethacrylate (UDMA) and 2,2-bis-[4-(2-hydroxy-3-methacryloyloxypropoxy) phenyl]-propane (Bis-GMA), have a high molecular weight and a low vapor pressure. The polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber with a medium polarity was employed for DI-SPME, and 215 nm of detection wavelength was found to be optimum in the chromatogram of HPLC measurement. The calibration range for DI-SPME was 0.30-300 μg/mL with correlation coefficients (r) greater than 0.998 for each analyte. The DI-SPME method achieved good accuracy (recovery 96.1-101.2%) and precision (2.30-8.15% CV) for both intra- and inter-day assays of quality control samples for three target compounds. Method validation was performed on standards dissolved in blank saliva, and there was no significant difference (p>0.2) between the DI-SPME method and the liquid injection method. However, the detection limit of DI-SPME was as low as 0.03, 0.27 and 0.06 μg/mL for TEGDMA, UDMA and Bis-GMA, respectively. Real sample analyses were performed on commercial dentin products after curing for the leaching measurement. In summary, DI-SPME is a more sensitive method that requires less sample pretreatment procedures to measure the resin materials leached in saliva.

  2. Speciation of chromium by dispersive liquid–liquid microextraction followed by laser-induced breakdown spectrometry detection (DLLME–LIBS)

    OpenAIRE

    Gaubeur, Ivanise; Aguirre Pastor, Miguel Ángel; Kovachev, Nikolay; Hidalgo Núñez, Montserrat; Canals Hernández, Antonio

    2015-01-01

    In this study, an analytical methodology based on a combination of dispersive liquid–liquid microextraction with laser-induced breakdown spectrometry was evaluated for simultaneous pre-concentration, speciation and detection of Cr. The microextraction procedure was based on the injection of appropriated quantities of 1-undecanol and ethanol into a sample solution containing the complexes formed between Cr(VI) and diethyldithiocarbamate (DDTC). The main experimental factors affecting the compl...

  3. Evaluation and significance of hyperchromatic crowded groups (HCG) in liquid-based paps

    Science.gov (United States)

    Chivukula, Mamatha; Austin, R Marshall; Shidham, Vinod B

    2007-01-01

    Objective Hyperchromatic crowded groups (HCG), a term first introduced into the cytology literature by DeMay in 1995, are commonly observed in Pap tests and may rarely be associated with serious but difficult to interpret lesions. In this study, we specifically defined HCG as dark crowded cell groups with more than 15 cells which can be identified at 10× screening magnification. Methods We evaluated consecutive liquid-based (Surepath) Pap tests from 601 women (age 17–74 years, mean age 29.4 yrs) and observed HCG in 477 cases. In all 477 HCG cases, Pap tests were found to be satisfactory and to contain an endocervical sample. HCG were easily detectible at 10× screening magnification (size up to 400 um, mean 239.5 um) and ranged from 1 to 50 (mean 19.5) per Pap slide. Results HCG predominantly represented 3-Dimensional groups of endocervical cells with some nuclear overlap (379/477 – 79%), reactive endocervical cells with relatively prominent nucleoli and some nuclear crowding (29/477 – 6%), clusters of inflammatory cells (25/477 – 5.2%), parabasal cells (22/477 – 4.6%), endometrial cells (1/477 – 0.2%). Epithelial cell abnormalities (ECA) were present in only 21 of 477 cases (4.6%). 18 of 21 women with HCG-associated ECA were less than 40 years old; only 3 were =/> 40 years. HCG-associated final abnormal Pap test interpretations were as follows: ASCUS (6/21 – 28%), LSIL (12/21 – 57%), ASC-H (2/21 – 9.5%), and HSIL/CIN2-3 (3/21 – 14%). The association of HCG with ECA was statistically significant (p = 0.0174. chi-square test). In patients with ECA, biopsy results were available in 10 cases, and 4 cases of biopsy-proven CIN2/3 were detected. Among these four cases, HCG in the Pap tests, in retrospect represented the lesional high grade cells in three cases (one HSIL case and two ASC-H cases). Interestingly, none of the 124 cases without HCG were found to have an epithelial cell abnormality. Conclusion We conclude: a. HCG are observed in a high

  4. 液相微萃取-高效液相色谱法分析葡萄汁中多酚类化合物%Determination of polyphenols in grape juice by liquid-phase microextraction coupled with high performance liquid chromatography

    Institute of Scientific and Technical Information of China (English)

    胡玉玲; 常蓓蓓; 罗学军; 李攻科

    2009-01-01

    A novel method for the determination of ellagic acid, resveratrol and quercetin in grape juice by liquid-phase microextraction (LPME) coupled with high performance liquid chromatography (HPLC) was developed. The results of two different modes of LPME were compared, and the single drop microextraction exhibited better extraction efficiency. Effects of stirring speed, extraction time, ionic strength, and pH were investigated. The enrichment factors of ellagic acid, resveratrol and quercetin were 48.4, 79.4 and 155.8, respectively. The linear range of the method was from 0.0050 to 5.0 μg/mL. The detection limits of ellagic acid, resveratrol and quercetin were 0.015, 0.0020, 0.0080 μg/mL, and the RSDs were 2.0%, 1.8% and 1.7%, respectively. The recoveries were from 81.9% to 102.3% for grape juice samples. The method with little solvent consumption was simple, fast, sensitive and suitable for the determination of polyphenols in plant samples.%建立了一种基于液相微萃取与高效液相色谱联用技术测定葡萄汁中鞣花酸、白藜芦醇和槲皮素的分析方法. 比较了单液滴液相微萃取和中空纤维液相微萃取两种萃取模式, 选择了单液滴液相微萃取作为3种多酚类化合物的液相微萃取模式. 考察了搅拌速度、萃取时间、料液相pH和料液相离子强度的影响. 鞣花酸、白藜芦醇和槲皮素的富集倍数分别为48.4、 79.4和155.8, 方法的线性范围为0.0050~5.0 μg/mL, 鞣花酸、白藜芦醇和槲皮素的检出限分别为0.015, 0.0020, 0.0080 μg/mL, 相对标准偏差分别为2.0%, 1.8%和1.7%. 用于实际样品葡萄汁的分析, 加标回收率在81.9%~102.3%之间.

  5. Porous, High Capacity Coatings for Solid Phase Microextraction by Sputtering.

    Science.gov (United States)

    Diwan, Anubhav; Singh, Bhupinder; Roychowdhury, Tuhin; Yan, DanDan; Tedone, Laura; Nesterenko, Pavel N; Paull, Brett; Sevy, Eric T; Shellie, Robert A; Kaykhaii, Massoud; Linford, Matthew R

    2016-02-01

    We describe a new process for preparing porous solid phase microextraction (SPME) coatings by the sputtering of silicon onto silica fibers. The microstructure of these coatings is a function of the substrate geometry and mean free path of the silicon atoms, and the coating thickness is controlled by the sputtering time. Sputtered silicon structures on silica fibers were treated with piranha solution (a mixture of concd H2SO4 and 30% H2O2) to increase the concentration of silanol groups on their surfaces, and the nanostructures were silanized with octadecyldimethylmethoxysilane in the gas phase. The attachment of this hydrophobic ligand was confirmed by X-ray photoelectron spectroscopy and contact angle goniometry on model, planar silicon substrates. Sputtered silicon coatings adhered strongly to their surfaces, as they were able to pass the Scotch tape adhesion test. The extraction time and temperature for headspace extraction of mixtures of alkanes and alcohols on the sputtered fibers were optimized (5 min and 40 °C), and the extraction performances of SPME fibers with 1.0 or 2.0 μm of sputtered silicon were compared to those from a commercial 7 μm poly(dimethylsiloxane) (PDMS) fiber. For mixtures of alcohols, aldehydes, amines, and esters, the 2.0 μm sputtered silicon fiber yielded signals that were 3-9, 3-5, 2.5-4.5, and 1.5-2 times higher, respectively, than those of the commercial fiber. For the heavier alkanes (undecane-hexadecane), the 2.0 μm sputtered fiber yielded signals that were approximately 1.0-1.5 times higher than the commercial fiber. The sputtered fibers extracted low molecular weight analytes that were not detectable with the commercial fiber. The selectivity of the sputtered fibers appears to favor analytes that have both a hydrophobic component and hydrogen-bonding capabilities. No detectable carryover between runs was noted for the sputtered fibers. The repeatability (RSD%) for a fiber (n = 3) was less than 10% for all analytes tested

  6. Efficient production of free fatty acids from ionic liquid-based acid- or enzyme-catalyzed bamboo hydrolysate.

    Science.gov (United States)

    Mi, Le; Qin, Dandan; Cheng, Jie; Wang, Dan; Li, Sha; Wei, Xuetuan

    2017-03-01

    Two engineered Escherichia coli strains, DQ101 (MG1655 fadD (-))/pDQTES and DQ101 (MG1655 fadD (-))/pDQTESZ were constructed to investigate the free fatty acid production using ionic liquid-based acid- or enzyme-catalyzed bamboo hydrolysate as carbon source in this study. The plasmid, pDQTES, carrying an acyl-ACP thioesterase 'TesA of E. coli in pTrc99A was constructed firstly, and then (3R)-hydroxyacyl-ACP dehydratase was ligated after the TesA to give the plasmid pDQTESZ. These two strains exhibited efficient fatty acid production when glucose was used as the sole carbon source, with a final concentration of 2.45 and 3.32 g/L, respectively. The free fatty acid production of the two strains on xylose is not as efficient as that on glucose, which was 2.32 and 2.96 g/L, respectively. For mixed sugars, DQ101 (MG1655 fadD (-))-based strains utilized glucose and pentose sequentially under the carbon catabolite repression (CCR) regulation. The highest total FFAs concentration from the mixed sugar culture reached 2.81 g/L by DQ101 (MG1655 fadD (-))/pDQTESZ. Furthermore, when ionic liquid-based enzyme-catalyzed bamboo hydrolysate was used as the carbon source, the strain DQ101 (MG1655 fadD (-))/pDQTESZ could produce 1.23 g/L FFAs with a yield of 0.13 g/g, and while it just produced 0.65 g/L free fatty acid with the ionic liquid-based acid-catalyzed bamboo hydrolysate as the feedstock. The results suggested that enzymatic catalyzed bamboo hydrolysate with ionic liquid pretreatment could serve as an efficient feedstock for free fatty acid production.

  7. Liquid-Based Endometrial Cytology Using SurePath™ Is Not Inferior to Suction Endometrial Tissue Biopsy in Clinical Performance for Detecting Endometrial Cancer Including Atypical Endometrial Hyperplasia.

    Science.gov (United States)

    Yanaki, Fumiko; Hirai, Yasuo; Hanada, Azusa; Ishitani, Ken; Matsui, Hideo

    2017-01-01

    We evaluated the clinical performance of liquid-based endometrial cytology (SurePath™) for detecting endometrial malignancies by comparison with the performance of suction endometrial tissue biopsy. From November 2011 to May 2013, we consecutively collected 1,118 liquid-based endometrial cytology specimens and 674 suction endometrial tissue biopsy specimens. The rate of nonpositive final histology in nonpositive liquid-based endometrial cytology (98.2%) was higher than the rate of nonpositive final histology in nonpositive suction endometrial tissue biopsy (97.0%). None of the clinical performance values of liquid-based endometrial cytology for detecting the endometrial malignancies were statistically inferior to those of the suction endometrial tissue biopsy. When the positivity threshold was more than "atypical endometrial cells of undetermined significance," the rate of positive liquid-based endometrial cytology from cases with a positive final histology (84.5%) was higher than the rate of positive suction endometrial tissue biopsy from cases with a positive final histology (69.8%). However, there were still no significant differences among all the performance values. Our liquid-based endometrial cytology would be more appropriate in various clinical situations as the initial detection tool for endometrial malignancies, rather than suction endometrial tissue biopsy. In addition, it could be used in screening for endometrial malignancies on a broader scale. © 2017 S. Karger AG, Basel.

  8. Novel Brønsted-acidic ionic liquids based on benzothiazolium cations as catalysts for esterification reactions

    Directory of Open Access Journals (Sweden)

    Song Hang

    2011-01-01

    Full Text Available Three novel Brønsted-acidic ionic liquids based on benzothiazolium cations were prepared, which served as catalysts for the synthesis of benzoic esters. All three gave good yields of the target esters in esterification reactions. Moreover, they combine the advantages of both homogeneous and heterogeneous solid catalysts in esterification reactions, which enabled them to serve as homogeneous catalysts to catalyze the reactions and be conveniently recovered by simple filtration after the reactions. They could be reused several times without noticeable decrease in efficiency.

  9. [Liquid-based cervical cytology ThinPrep screening in Hungary].

    Science.gov (United States)

    Bak, Mihály; Séberné Éll, Mária; Bóka, Melinda; Veleczki, Zsuzsanna; Nyári, Tibor; Pete, Imre; Szentirmay, Zoltán

    2014-05-04

    Bevezetés: A hagyományos Papanicolaou-cervixkenetet világszerte az úgynevezett folyadékalapú (liquid-based) citológia váltotta fel. Egyértelműen bizonyított, hogy a folyadékalapú citológia alternatív módszer. Célkitűzés: A dolgozat célja a folyadékalapú méhnyakrákszűrés magyarországi eredményeinek, diagnózisainak követése, citohisztológiai összehasonlítása, illetve minőségbiztosítása volt. Módszer: 4573 folyadékalapú citológiai cervixkenetet a Bethesda (2001) beosztás szerint klasszifikálták. A humán papillomavírus tipizálását valós idejű polimeráz láncreakció módszerével határozták meg. Eredmények: A diagnózisok megoszlása: negatív 2323 (50,8%), egyéb, nem neoplasticus 2017 (44,1%) és kóros, neoplasticus 233 (5,1%). A nem értékelhető kenetek száma 43 (0,9%) volt, mérsékelt fokú intraepithelialis laesiót 87 esetben (1,9%), kifejezett fokú intraepithelialis laesiót 24 esetben (0,5%), carcinomát 23 esetben (0,5%) észleltek. A citológiai és hisztológiai leletek közötti korreláció alapján a módszer szenzitivitása 93,2%, specificitása 100%, pozitív prediktív értéke 100%-nak bizonyult. A folyadékalapú citológiai módszerrel a mérsékelt és kifejezett fokú intraepithelialis laesiót mutató kenetek aránya az előző évek azonos időtartamához viszonyítva 0,82%-ról 2,51%-ra emelkedett. Humán papillomavírus-DNS-meghatározást 81 esetben végeztek (pozitív prediktív érték 99%). Az 51 kóros hámelváltozás kapcsán 50 (98%) esetben igazolódott humán papillomavírus-fertőzés, ezek közül 20 (24,7%) alacsony, 46 (56,8%) pedig magas kockázatú volt. Következtetések: A szerzők megállapították, hogy tanulmányukban a folyadékalapú cervixcitológiai vizsgálat minőségbiztosítási eredményei megfelelnek a nemzetközileg elvártaknak. A folyadékalapú vizsgálat alternatív cervixcitológiai módszer, és hatékonysága, valamennyi paramétert tekintve

  10. Efficiency of an inexpensive liquid-based cytology performed by cytocentrifugations: a comparative study using the histology as reference standard

    Directory of Open Access Journals (Sweden)

    Garbar Christian

    2005-09-01

    Full Text Available Abstract Background Although liquid-based cytology (LBC is now recommended for cervical cancer screening, it requires expensive automated devices and materials. To evaluate the efficiency of inexpensive LBC methods relying on an inexpensive fixative liquid, Easyfix®, we compared the results obtained by the liquid-based cytology (LBC diagnoses performed by cytocentrifugations (Papspin® and Turbitec® with those obtained by histology. Furthermore, we evaluated the efficiency of the fixative liquid, Easyfix®, to preserve HPV DNA in the collected samples. Method 266 LBC were compared with 174 colposcopies and 91 Loop Electrosurgical Excision Procedure (LEEP. Among the LBC, 51 were performed using the Papspin® system and 215 were performed using the Turbitec® system. To control the quality of the preservation liquid, Easyfix®, we correlated the results of HCII assays with those of HPV PCR. Results For Papspin® and Turbitec® systems, the sensitivities were respectively 82.6% (95% CI: 61.2–95.0%, p Conclusion LBC performed by cytocentrifugations are inexpensive, reduce inadequate smears, show excellent efficiency and allow HPV detection by molecular biology.

  11. Cost is a Barrier to Widespread Use of Liquid-Based Cytology for Cervical Cancer Screening in Korea

    Science.gov (United States)

    Chung, Hyun Hoon; Kang, Soon-Beom

    2006-01-01

    This study aimed to document current cervical cancer screening practices of physicians in Korea. Questionnaires were distributed to 852 Korean obstetricians and gynecologists, who attended the 91st Conference of the Korean Society of Obstetrics and Gynecology held during May, 2005. Questionnaires were returned by 30.6% (260/852) of the recipients and 254 of these were eligible for analysis. Sixty-seven percent started cervical cancer screening women at age 20, and 65% replied that they would continue annual screening in a 35-yr-old woman with three consecutive normal cytologic tests. Over 65% of respondents preferred conventional cytologic screening to liquid-based cytology. The cost was a major determinant for selecting screening method. Fifty-three percent used the human papillomavirus DNA test as a triage for atypical squamous cells of undetermined significance. Our findings suggest that majority of Korean obstetricians and gynecologists in hospital prefer annual conventional cytologic testing to liquid-based cytology for financial reason. PMID:17179686

  12. Comparison of liquid-based preparation and conventional smear of fine-needle aspiration cytology of lymph node.

    Science.gov (United States)

    Singh, Priya; Rohilla, Manish; Dey, Pranab

    2016-01-01

    In this paper, we have compared the cytomorphologic characteristics of liquid-based preparation (LBP) [SurePath (SP)] cytology and conventional smear (CP) preparations on fine-needle aspiration (FNAC) material by a semi-quantitative scoring system for cases of lymphadenopathy. In this prospective study, a total of 52 consecutive cases of FNAC of lymphadenopathy were included. The first pass was used for CP followed by LBP with the help of SP technique. The smears were independently compared and assessed by two observers (PS and PD). The semiquantitative grading was compared in two groups by Wilcoxon signed-rank test. The background information, cell architecture, pleomorphism, nuclear and cytoplasmic details, and three-dimensional structures were significantly different in LBP and CP smears. Liquid-based cytology (LBC) is a relatively simple technique, which exhibits good nuclear and cytoplasmic details with the absence of obscuring background material. Even the number of slides and area per slide to be screened were less than the conventional preparation but caution must be applied to interpret the slides and secure a diagnosis, especially if LBC is the first and only method applied for diagnosis.

  13. Liquid-based thin-layer cytology can be routinely used in samples obtained via fiberoptic bronchoscope.

    Science.gov (United States)

    Kobayashi, Yukihiro; Uehara, Takeshi; Ota, Hiroyoshi

    2011-01-01

    The aim of this study was to evaluate liquid-based preparations (LBP) as a replacement for conventional smears (CS) of bronchial brushing (BB) and transbronchial fine-needle aspiration (TBNA) samples obtained via fiberoptic bronchoscope. Bronchial brushing and TBNA samples were obtained from 62 and 33 patients by fiberoptic bronchoscopy, respectively. Liquid-based preparations were prepared from needle rinse after initial CS preparation. We compared cellularity, cell morphology, and background between the LBP and CS slides. Correspondence rates between LBP and CS diagnoses in the above 3 categories were 90.3% in the BB and 97.0% in the TBNA samples. If suspicious cases were regarded as malignant, correspondence rates reached 98.4 and 100%, respectively. Histological diagnoses by LBP were mostly the same as those by CS and by biopsy or operation samples. Morphologically, cells and nuclei were shrunk in the LBP; however, the shrinking was not severe enough to influence cytological diagnoses. Blood background and air-drying, which were observed on many of the CS slides, were not detected on the LBP slides. It is possible to use LBP for routine laboratory processing of BB and TBNA samples as a replacement for CS. Copyright © 2010 S. Karger AG, Basel.

  14. Comparison of three sampling instruments, Cytobrush, Curette and OralCDx, for liquid-based cytology of the oral mucosa.

    Science.gov (United States)

    Reboiras-López, M D; Pérez-Sayáns, M; Somoza-Martín, J M; Antúnez-López, J R; Gándara-Vila, P; Gayoso-Diz, P; Gándara-Rey, J M; García-García, A

    2012-01-01

    Exfoliative cytology of the oral cavity is a simple and noninvasive technique that permits the study of epithelial cells. Liquid-based cytology is an auxiliary diagnostic tool for improving the specificity and sensitivity of conventional cytology. The objective of our study was to compare the quality of normal oral mucosa cytology samples obtained using three different instruments, Cytobrush®, dermatological curette and Oral CDx® for liquid-based cytology. One hundred four cytological samples of oral cavity were analyzed. Samples were obtained from healthy volunteer subjects using all three instruments. The clinical and demographic variables were age, sex and smoking habits. We analyzed cellularity, quality of the preparation and types of cells in the samples. All preparations showed appropriate preparation quality. In all smears analyzed, cells were distributed uniformly and showed no mucus, bleeding, inflammatory exudate or artifacts. We found no correlation between the average number of cells and the type of instrument. The samples generally consisted of two types of cells: superficial and intermediate. No differences were found among the cytological preparations of these three instruments. We did not observe basal cells in any of the samples analyzed.

  15. Dispersive Liquid-Liquid Microextraction and determination of Platinum(IV by High Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    Ali Mazloomifar

    2015-09-01

    Full Text Available A simple, rapid, and efficient procedure, dispersive liquid-liquid microextraction (DLLME, has been developed for the extraction and preconcentration of platinum (IV in environmental water samples. The factors relevant to the microextraction efficiency, such as the kind and volume of extraction and dispersive solvent, the extraction time, the pH in aqueous, and the salt effect, were optimized. Under the optimum conditions , the enrichment factor of this method for platinum was reached at 119. The detection limit for platinum was 0.3 ng mL-1 , and the relative standard deviation (RSD was 0.42% (n = 10 , C = 10 ng mL-1. The method was successfully applied to the determination of trace amounts of platinum in environmental water samples.

  16. Determination of aromatic amines from textiles using dispersive liquid-liquid microextraction.

    Science.gov (United States)

    Yang, Lu; Yiwei, Wang; Caiying, Lou; Yan, Zhu

    2013-03-01

    A dispersive liquid-liquid microextraction procedure coupled with GC-MS is described for preconcentration and determination of banned aromatic amines from textile samples. Experimental conditions affecting the microextraction procedure were optimized. A mixture of 30 μL chlorobenzene (extraction solvent) and 800 μL ACN (disperser solvent), 5 min extraction time, and 5 mL aqueous sample volume were chosen for the best extraction efficiency by the proposed procedure. Satisfactory linearity (with correlation coefficients >0.9962) and repeatability (<9.78%) were obtained for all 20 aromatic amines; detection limits attained were much lower than the standardized liquid-liquid method. The proposed method has advantages of being quicker and easier to operate, and lower consumption of organic solvent.

  17. On-line extraction and determination of two herbicides: comparison between two modes of three-phase hollow fiber microextraction.

    Science.gov (United States)

    Tajik, Mohammad; Yamini, Yadollah; Esrafili, Ali; Ebrahimpour, Behnam

    2015-02-01

    Two different modes of three-phase hollow fiber liquid-phase microextraction were studied for the extraction of two herbicides, bensulfuron-methyl and linuron. In these two modes, the acceptor phases in the lumen of the hollow fiber were aqueous and organic solvents. The extraction and determination were performed using an automated hollow fiber microextraction instrument followed by high-performance liquid chromatography. For both three-phase hollow fiber liquid-phase microextraction modes, the effect of the main parameters on the extraction efficiency were investigated and optimized by central composite design. Under optimal conditions, both modes showed good linearity and repeatability, but the three-phase hollow fiber liquid-phase microextraction based on two immiscible organic solvents has a better extraction efficiency and figures of merit. The calibration curves for three-phase hollow fiber liquid-phase microextraction with an organic acceptor phase were linear in the range of 0.3-200 and 0.1-150 μg/L and the limits of detection were 0.1 and 0.06 μg/L for bensulfuron-methyl and linuron, respectively. For the conventional three-phase hollow fiber liquid-phase microextraction, the calibration curves were linear in the range of 3.0-250 and 15-400 μg/L and LODs were 1.0 and 5.0 μg/L for bensulfuron-methyl and linuron, respectively. The real sample analysis was carried out by three-phase hollow fiber liquid phase microextraction based on two immiscible organic solvents because of its more favorable characteristics.

  18. Dispersive Liquid-Liquid Microextraction in the Analysis of Milk and Dairy Products: A Review

    OpenAIRE

    Andrew Quigley; Wayne Cummins; Damian Connolly

    2016-01-01

    Dispersive liquid-liquid microextraction (DLLME) is an extraction technique developed within the last decade, which involves the dispersion of fine droplets of extraction solvent in an aqueous sample. Partitioning of analytes into the extraction phase is instantaneous due to the very high collective surface area of the droplets. This leads to very high enrichment factors and very low solvent consumption, relative to other liquid or solid phase extraction methods. A comprehensive review of the...

  19. The recent developments in dispersive liquid–liquid microextraction for preconcentration and determination of inorganic analytes

    OpenAIRE

    H.M. Al-Saidi; Adel A.A. Emara

    2014-01-01

    Recently, increasing interest on the use of dispersive liquid–liquid microextraction (DLLME) developed in 2006 by Rezaee has been found in the field of separation science. DLLME is miniaturized format of liquid–liquid extraction in which acceptor-to-donor phase ratio is greatly reduced compared with other methods. In the present review, the combination of DLLME with different analytical techniques such as atomic absorption spectrometry (AAS), inductively coupled plasma-optical emission spectr...

  20. Selective fiber used for headspace solid-phase microextraction of abused drugs in human urine

    OpenAIRE

    Sunanta Wangkarn

    2007-01-01

    A sensitive and selective fiber for simultaneous analysis of three drugs of abuse (amphetamine, methamphetamine and ephedrine) in urine samples was explored using headspace solid phase microextraction and gas chromatography with flame ionization detection. Several parameters affecting extraction such as extraction time, extraction temperature, pH of solution and salt concentrations were investigated. Among five commercially available fibers, divinylbenzene/carboxen/ polydimethylsiloxane is th...

  1. Solid-phase microextraction for flavor analysis in Harari Khat (Catha edulis) stimulant

    Institute of Scientific and Technical Information of China (English)

    AL-FLAHI Abdulsalam; ZOU Jian-kai (邹建凯); YIN Xue-feng (殷学锋)

    2004-01-01

    This research examined the typical flavor compounds in the commonest type of Khat called Harari Khat grown in the region of Ethiopia. Twenty-eight compounds, which includes 1,2-Propanedione, 1-Phenyl, Hexanol, Hexanal compounds, Limonene, Benzaldehyde with other flavors, were extracted by polydimethylsiloxane at room temperature for 30 min from Khat samples, and identified by solid-phase microextraction-gas chromatography-mass spectrometry (SPME- GC-MS). This method needs no organic solvents and required minimal sample.

  2. Spectrophotometric determination of iron species using ionic liquid ultrasound assisted dispersive liquid--liquid microextraction

    OpenAIRE

    BAZMANDEGAN, ALIREZA; Shabani,Ali Mohammad Haji; DADFARNIA, SAYESSTEH; Saeidi, Mahboubeh; Moghadam,Masoud Rohani

    2015-01-01

    A simple and efficient method for speciation and determination of iron in different water samples was developed. The method is based on ionic liquid ultrasound assisted dispersive liquid--liquid microextraction (IL-USA-DLLME) followed by spectrophotometric determination. Fe(II) is complexed with 2,4,6-tri(2'-pyridyl)-l,3,5-triazine (TPTZ{)}, neutralized through ion pair formation with sodium dodecyl sulfate (SDS) and extracted into 1-hexyl-3-methylimidazolium hexafluorophosphate [C$_...

  3. Extraction and Separation of Molybdenum by Using Homogeneous Liquid-Liquid Microextraction via Flotation Assistance

    OpenAIRE

    Rezaee, Mohammad; Mozaffari,Maryam; Haddadi,Hedayat; Pourjavid,Mohammad R.; SEMNANI, Abolfazl

    2015-01-01

    Homogeneous liquid-liquid microextraction via flotation assistance (HLLME-FA) was investigated for the extraction of molybdenum from the water samples. Alizarin Red S and cetyl trimethylammonium bromide (CTAB) were used as a complexing ligand and ion-pairing reagent, respectively. The enriched analyte in the floated organic phase was determined by electrothermal atomic absorption spectrometry (ETAAS). In this work, low density organic solvent was used and no centrifugation was required in thi...

  4. Spectroscopic analysis of bosentan in biological samples after a liquid-liquid microextraction

    Science.gov (United States)

    Sajedi-Amin, Sanaz; Assadpour-Zeynali, Karim; Panahi-Azar, Vahid; Kebriaeezadeh, Abbas; Khoubnasabjafari, Maryam; Ansarin, Khalil; Jouyban-Gharamaleki, Vahid; Jouyban, Abolghasem

    2015-01-01

    Introduction:Microextraction processes with UV-Vis measurement have been developed and validated for analysis of bosentan in biological samples. Methods:In this work, liquid–liquid microextraction procedures (DLLME & USAEME) were employed for cleanup, pre-concentration, and determination of bosentan in biological samples by UV-Vis spectroscopy at 270 nm. The method was validated and applied to the determination of bosentan in spiked serum, exhaled breath condensate and urine samples. Results:Various experimental factors including type of extraction and dispersive solvents and their volumes, pH, sonication time and centrifuging time were investigated. Under the optimum conditions, the method was linear in the range of 1.0–5.0 μg.mL-1, with coefficient of determination (R2) of > 0.998. The limit of detection (LOD) was 0.07 mg.L-1. Recovery of the target analyte in biological samples was 106.2%. The method could be easily applied for higher concentration of bosentan and needs more improvement for application in the pharmacokinetic investigations where more sensitive methods are required. Conclusion:A simple, low cost, precise and accurate spectrophotometric analysis of bosentan in biological samples after liquid-liquid microextraction were developed and validated for routine analyses. PMID:26929923

  5. Application of vesicular coacervate phase for microextraction based on solidification of floating drop.

    Science.gov (United States)

    Moradi, Morteza; Yamini, Yadollah

    2012-03-16

    A new, efficient and environmentally friendly method for the analysis of parabens as model compounds was developed using solidified floating vesicular coacervative drop microextraction (SFVCDME). A supramolecular solvent consisting of vesicles of decanoic acid in the nano- and microscale regimes was firstly used as the solvent in solidification of floating drop microextraction. The solvent was produced from the coacervation of decanoic acid aqueous vesicles in the presence of tetrabutylammonium (Bu(4)N(+)). Methylparaben (MP), ethylparaben (EP), and propylparaben (PP) were extracted on the basis of hydrophobic and π-cation interactions and the formation of hydrogen bonds. Microliter volume of vesicular coacervative droplet was delivered to the surface of the aqueous sample, and the sample was stirred for a desired time. The sample vial was cooled by immersing it into an ice bath for 3 min. The solidified solvent was transferred into a suitable vial and melted immediately. Twenty microliter of the vesicular coacervative solvent was directly injected to high-performance liquid chromatography-ultraviolet detection, with no need to dilution or solvent evaporation. Several parameters affecting the microextraction efficiency including sample temperature, stirring rate, pH, salt effect, volume of the solvent and extraction time were investigated and optimized. Under optimum conditions, preconcentration factors and relative recoveries of the studied compounds were obtained in the range of 81-174 and 91-108%, respectively; and the performance of the method was comparable with that of solid-phase extraction as the reference method.

  6. SOLID PHASE MICROEXTRACTION FOR TRACE ANALYSIS OF BENZENE IN ENVIRONMENTAL MONITORING

    Directory of Open Access Journals (Sweden)

    S. J. Shahtaheri, H. R. Heidari, F. Golbabaei, M. Alimohammadi, A. Rahimi Froshani

    2006-07-01

    Full Text Available Conventional analytical method for organic pollutants in water requires extraction of the pollutants, using hazardous solvent. Solid phase microextraction is a solvent free equilibrium extraction method, in which, proper calibration can allow quantitative determinations of organic pollutants at a very good sensitivity without the use of any organic solvent. Because individual volatile organic carbons are generally exposed environmentally and present in urine only at trace levels, a sensitive and accurate determination technique is essential. So, this study describes the optimization of headspace solid phase microextraction (HS-SPME followed by GC-FID for benzene in spiked urine. Through this investigations, the parameters affecting the extraction and gas chromatographic determination of analytes, including extraction time, temperature, desorption temperature, desorption time, salt addition, sample pH, sample volume and sample agitation were studied. An optimized headspace extraction was carried out at 30°C for 6 min in the presence of 0.2 g/mL of NaCl in the sample solution. Desorption of the analytes was carried out for 60 sec. at 250°C. The optimized procedure was also validated with three different pools of spiked urine samples and showed a good reproducibility over six consecutive days as well as six within-day experiments. The accuracy, linearity, detection limits were also determined. The headspace solid phase microextraction, GC-FID technique provides a relatively simple, convenient, practical procedure, which was here successfully applied to determine benzene in spiked urine.

  7. Sorbent coated glass wool fabric as a thin film microextraction device.

    Science.gov (United States)

    Riazi Kermani, Farhad; Pawliszyn, Janusz

    2012-11-06

    A new approach for thin film microextraction (TFME) with mixed-phase sorptive coating is presented. Carboxen/polydimethylsiloxane (CAR/PDMS) and polydimethylsiloxane/divinylbenzene (PDMS/DVB) TFME samplers were prepared using spin coating and glass wool fabric mesh as substrate. The samplers were easily tailored in size and shape by cutting tools. Good durability and flat-shape stability were observed during extraction, stirring in water, and thermal desorption. The latter characteristic obviates the need for an extra framed holder for rapid TFME and makes the samplers more robust and easier to deploy. The samplers combine the advantages of adsorptive solid-phase microextraction (SPME) and TFME, including one-step solvent-free extraction and preconcentration, direct thermal desorption, and enhanced sensitivity without sacrificing analysis time due to thin film geometry. The analytical performance of these new devices was demonstrated using water samples spiked with N-nitrosamines (NAs) as model compounds. Over an order of magnitude enhancement of extraction efficiencies was obtained for the model compounds compared with the SPME fibers of similar coatings and PDMS thin film membrane. The results of this study indicate that these novel thin film devices are promising for rapid and efficient microextraction of polar analytes in water.

  8. Analysis of Whiskey by Dispersive Liquid-Liquid Microextraction Coupled with Gas Chromatography/Mass Spectrometry: An Upper Division Analytical Chemistry Experiment Guided by Green Chemistry

    Science.gov (United States)

    Owens, Janel E.; Zimmerman, Laura B.; Gardner, Michael A.; Lowe, Luis E.

    2016-01-01

    Analysis of whiskey samples prepared by a green microextraction technique, dispersive liquid-liquid microextraction (DLLME), before analysis by a qualitative gas chromatography-mass spectrometry (GC/MS) method, is described as a laboratory experiment for an upper division instrumental methods of analysis laboratory course. Here, aroma compounds in…

  9. Comparison of simultaneous distillation extraction and solid-phase micro-extraction for determination of volatile constituents in tobacco flavor

    Institute of Scientific and Technical Information of China (English)

    ZHONG Ke-jun; WEI Wan-zhi; GUO Fang-qiu; HUANG Lan-fang

    2005-01-01

    The volatile and semi-volatile components in tobacco flavor additives were extracted by both simultaneous distillation extraction and solid-phase micro-extraction. Extraction conditions for solid-phase micro-extraction were optimized with information theory. Then, detection were accomplished by gas chromatography-mass spectrometry. Characteristic of each method was compared. Qualitative analysis and quantitative analysis of 6# tobacco flavor sample were accomplished through both simultaneous distillation extraction and solid-phase micro-extraction. The experimental results show that solid-phase micro-extraction method is the first choice for qualitative analysis and simultaneous distillation extraction is another good selection for quantitative analysis. By means of simultaneous distillation extraction, 20 components are identified, accounting for 92.77% of the total peak areas. Through solid-phase micro-extraction, there are 17 components identified accounting for 91.49% of the total peak areas. The main aromatic components in 6# tobacco flavor sample are propanoic acid, 2-hydroxy-, ethyl ester, menthol and menthyl acetate. The presented method has been successfully used for quality control of tobacco flavor.

  10. Molecular tests for human papillomavirus (HPV, Chlamydia trachomatis and Neisseria gonorrhoeae in liquid-based cytology specimen

    Directory of Open Access Journals (Sweden)

    Vigliotti Veronica S

    2009-04-01

    Full Text Available Abstract Background Laboratory detection of Human papillomavirus (HPV, Chlamydia trachomatis and Neisseria gonorrhoeae in liquid-based cervicovaginal cytology specimens is now based on identification of the DNA sequences unique to these infectious agents. However, current commercial test kits rely on nucleotide probe hybridization to determine DNA sequences, which may lead to diagnostic errors due to cross-reactivity. The aim of this study was to find a practical approach to perform automated Sanger DNA sequencing in clinical laboratories for validation of the DNA tests for these three infectious agents. Methods A crude proteinase K digestate of 5% of the cells collected in a liquid-based cervicovaginal cytology specimen was used for the detection of DNA molecules specific for HPV, C trachomatis and N gonorrhoeae, and for preparation of materials suitable for direct automated DNA sequencing. Several sets of commercially available polymerase chain reaction (PCR primers were used to prepare nested PCR amplicons for direct DNA sequencing. Results Some variants of HPV-16 and HPV-31 were found to share an at least 34-base long sequence homology downstream of the GP5+ binding site, and all HPV-6 and HPV-11 variants shared an upstream 34-base sequence including part of the GP5+ primer. Accurate HPV genotyping frequently required more than 34-bases for sequence alignments to distinguish some of the HPV genotype variants with closely related sequences in this L1 gene hypervariable region. Using the automated Sanger DNA sequencing method for parallel comparative studies on split samples and to retest the residues of samples previously tested positive for C trachomatis and/or for N gonorrhoeae, we also found false-negative and false-positive results as reported by two commercial nucleic acid test kits. Conclusion Identification of a signature DNA sequence by the automated Sanger method is useful for validation of HPV genotyping and for molecular testing of

  11. Comparison between solid phase microextraction (SPME) and hollow fiber liquid phase microextraction (HFLPME) for determination of extractables from post-consumer recycled PET into food simulants.

    Science.gov (United States)

    Oliveira, Éder Costa; Echegoyen, Yolanda; Cruz, Sandra Andrea; Nerin, Cristina

    2014-09-01

    Hollow fiber liquid phase microextraction (HFLPME) and solid phase microextraction (SPME) methods for pre-concentration of contaminants (toluene, benzophenone, tetracosane and chloroform) in food simulants were investigated. For HFLPME 1-heptanol, 2-octanone and dibutyl-ether were studied as extracting solvents. Analysis by gas chromatography coupled to mass spectrometry (GC-MS), flame ionization (GC-FID) and electron capture detectors (GC-ECD) were carried out. In addition, the methods were employed to evaluate the safety in use of a PET material after the recycling process (comprising washing, extrusion and solid state polymerization (SSP)) through extractability studies of the contaminants using 10% (v/v) ethanol in deionized water and 3% (w/v) acetic acid in deionized water as food simulants in different conditions: 10 days at 40°C and 2h at 70°C. The HFLPME preconcentration method provided increased sensitivity when compared to the SPME method and allowed to analyze concentration levels below 10 µg surrogate per kg food simulant. The results of the extractability studies showed considerable reductions after the extrusion and SSP processes and indicated the compliance with regulations for using recycled PET in contact with food. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Do liquid-based preparations of urinary cytology perform differently than classically prepared cases? Observations from the College of American Pathologists Interlaboratory Comparison Program in Nongynecologic Cytology.

    Science.gov (United States)

    Laucirica, Rodolfo; Bentz, Joel S; Souers, Rhona J; Wasserman, Patricia G; Crothers, Barbara A; Clayton, Amy C; Henry, Michael R; Chmara, Beth Anne; Clary, Karen M; Fraig, Mostafa M; Moriarty, Ann T

    2010-01-01

    The cytomorphology of liquid-based preparations in urine cytology is different than classic slide preparations. To compare the performance of liquid-based preparation specimens to classically prepared urine specimens with a malignant diagnosis in the College of American Pathologists Interlaboratory Comparison Program in Nongynecologic Cytology. Participant responses between 2000 and 2007 for urine specimens with a reference diagnosis of high-grade urothelial carcinoma/carcinoma in situ/dysplasia (HGUCA), squamous cell carcinoma, or adenocarcinoma were evaluated. ThinPrep and SurePath challenges were compared with classic preparations (smears, cytospins) for discordant responses. There were 18 288 pathologist, 11 957 cytotechnologist, and 8086 "laboratory" responses available. Classic preparations comprised 90% (n = 34 551) of urine challenges; 9% (n = 3295) were ThinPrep and 1% (n = 485) were SurePath. Concordance to the general category of "positive-malignant" was seen in 92% of classic preparations, 96.5% of ThinPrep, and 94.6% of SurePath challenges (P Liquid-based preparations performed significantly better in urinary cytology challenges when evaluating malignant categories in the College of American Pathologists interlaboratory comparison program. The liquid-based preparation challenges also performed better for the exact reference interpretation of HGUCA, but no difference was observed for adenocarcinoma challenges. Cytotechnologists perform better than pathologists for all slide types, as well as those demonstrating HGUCA. These results suggest that liquid-based preparations facilitate a more accurate diagnosis than conventional preparations.

  13. Significance of atypia in conventional Papanicolaou smears and liquid-based cytology: a follow-up study

    DEFF Research Database (Denmark)

    Schledermann, D; Ejersbo, D; Hoelund, B

    2004-01-01

    The diagnosis of atypical squamous epithelial cells, borderline nuclear changes, is associated with some controversy, as it encompasses benign, reactive, as well as possible neoplastic conditions. The aim of this study was to evaluate the follow-up diagnoses of cytological atypia in conventional...... Papanicolaou smears (CP) and liquid-based samples by the ThinPrep Pap Test (TP). A total of 1607 CP smears from 1 January 2000 to 31 December 2000 and 798 TP samples from 1 January 2002 to 31 December 2002 diagnosed as atypia were included. The results show that the detection rate of atypia in cervical...... cytological samples was reduced by 41.3% (P Cytological and histological follow-up data showed the presence of neoplastic lesions in 34.7% of patients screened by TP versus 22.3% of patients screened by CP, corresponding to a 55.6% increase in TP (P

  14. Small Cell Carcinoma of the Uterine Cervix in a Pregnant Patient Diagnosed with Liquid Based Cytology and Cell Block Immunocytochemistry

    Directory of Open Access Journals (Sweden)

    Mawuli F. Attipoe

    2014-01-01

    Full Text Available Definitive cytomorphologic diagnosis of small cell carcinoma of the uterine cervix is possible but can be challenging in routine cervicovaginal cancer screening specimens. Several small series of reported cases of cervical small cell carcinoma have shown this uncommon malignancy to represent fewer than 2% of all invasive cervical cancers. This tumor type is associated with poor prognosis and rapid disease progression and can develop to an advanced stage in the interval between screening visits. Only rare case reports of small cell carcinoma arising in gravid cervices are known. In the current case a 29-year-old, gravida 6, para 2, pregnant (10-week gestation female presented with postcoital bleeding. A definitive diagnosis of small cell carcinoma of the cervix was made possible by liquid based Pap testing with ancillary cell block preparation allowing for immunocytochemical characterization of the lesional cell population.

  15. The diagnostic and prognostic role of liquid-based cytology: are we ready to monitor therapy and resistance?

    Science.gov (United States)

    Rossi, Esther Diana; Bizzarro, Tommaso; Longatto-Filho, Adhemar; Gerhard, Rene; Schmitt, Fernando

    2015-01-01

    Here, we evaluate the diagnostic and prognostic role of liquid-based cytology (LBC) in different body lesions, including thyroid, lung, effusions and malignant breast lesions. LBC has gained consensus after being applied to both non-gynecologic and fine-needle aspiration cytology. Although some remain sceptical regarding the diagnostic efficacy of LBC, mainly when used alone, in recent years, good results have been obtained as long as it showed a high diagnostic accuracy. Here, we discuss the additional possibility of storing material for the application of ancillary techniques (immunocytochemistry-molecular analysis) with several diagnostic and prognostic advantages, which may pave the way for the challenging evaluation of both monitoring responses to treatment and resistance to targeted therapies in thyroid, lung, breast carcinoma or malignant effusions. Furthermore, it provides the use of several molecular spots as specific targets for personalized therapy.

  16. Direct sampling of metastatic ovarian carcinoma masquerading as endocervical adenocarcinoma in liquid-based cytology cervical sample

    Science.gov (United States)

    Gupta, Nalini; Bhar, Vikrant; Dey, Pranab; Rajwanshi, Arvind; Suri, Vanita

    2014-01-01

    Cervical sample is routinely taken to identify squamous dysplastic lesions of the cervix. Glandular lesions are far less commonly reported on cervical samples. The most common glandular lesion reported on cervical smear is endocervical adenocarcinoma, followed by endometrial adenocarcinoma. Direct sampling by Cervex brush is possible even in endometrial adenocarcinoma, if the tumor directly involves lower uterine segment/endocervical canal. Metastases to cervix are rare but have occasionally been reported in previous reports. We wish to highlight in this case, metastatic ovarian carcinoma directly sampled in cervical liquid-based cytology (LBC) sample, which mimicked cytomorphologically a well-differentiated endocervical adenocarcinoma. To the best of our knowledge, a similar case has not been previously published in SurePath LBC sample. PMID:25538388

  17. Weeding atypical glandular cell look-alikes from the true atypical lesions in liquid-based Pap tests: a review.

    Science.gov (United States)

    Wood, Moira D; Horst, Julie A; Bibbo, Marluce

    2007-01-01

    The purpose of this review is to identify features that separate atypical glandular cells (AGC) associated with glandular neoplasia from its mimickers, both benign and neoplastic. We reviewed cases of AGC diagnosed on liquid-based Pap tests (LBP) for which corresponding histological follow-up was available. A review of the literature for similar studies in LBP tests was also conducted. We find that certain benign mimics can be reliably separated from AGC, but recommend caution in attempting to increase specificity at the risk of losing sensitivity. Although accounting for only a small percentage of diagnoses AGC require a thorough clinical evaluation, including colposcopy. Most cases are ultimately found to be benign. When evaluating smears suspicious for AGC, it is important to examine the subtle features which make truly atypical cells discernible from their numerous benign mimickers.

  18. Ionic liquid-based variable focus electrowetting optics with bandwidths spanning the visible to mid-infrared

    CERN Document Server

    Watson, Alexander M; Niederriter, Robert D; Terrab, Soraya; Gopinath, Juliet T; Bright, Victor M

    2016-01-01

    Infrared optical materials and devices are important for a wide range of applications in the defense, scientific, and consumer markets. For imaging, spectroscopy, microscopy and persistent surveillance, adaptive optic systems that span the visible to infrared region are particularly useful. We address this need with novel electrowetting lens and prism elements that operate from 400 to 5000 nm. In contrast to conventional electrowetting devices that use polar liquids, limited by high absorption in the infrared region, we present room-temperature ionic liquid-based (RTIL, N-Propyl-Nmethylpyrrolidinium Bis(fluorosulfonyl)imide, Pyr1333a, Solvionic) lens and prism elements with unprecedented spectral bandwidths. Our electrowetting lenses tune over 20 diopters and have been demonstrated at 588, 1550 and 3000 nm wavelengths. Additionally, we have demonstrated prism elements with a steering angle of 0.56{\\deg} at 1550 nm.

  19. Ionic liquid-based hydrothermal synthesis of Lu2O3 and Lu2O3:Eu3+ microcrysals

    Science.gov (United States)

    Li, Yinyan; Xu, Shiqing

    2016-09-01

    Uniform and well-defined Lu2O3 and Lu2O3:Eu3+ microarchitectures have been successfully synthesized via a green and facile ionic liquid-based hydrothermal method followed by a subsequent calcination process. Novel 3D micro-rodbundles and 1D microrods of Lu2O3 and Lu2O3:Eu3+ were controllably obtained through this method. X-ray powder diffraction, scanning electron microscopy, transmission electron microscopy and photoluminescence spectra were used to characterize the micromaterials. The proposed formation mechanisms have been investigated on the basis of a series of SEM studies of the products obtained at different hydrothermal durations. The results indicated that hydrothermal temperature and the ionic liquid-tetrabutylammonium hydroxide were two key factors for the formation as well as the morphology control of the Lu2O3 and Lu2O3:Eu3+ microarchitectures.

  20. Theoretical study of ionic liquids based on the cholinium cation. Ab initio simulations of their condensed phases

    Science.gov (United States)

    Campetella, Marco; Bodo, Enrico; Montagna, Maria; De Santis, Serena; Gontrani, Lorenzo

    2016-03-01

    We have explored by means of ab initio molecular dynamics the homologue series of 11 different ionic liquids based on the combination of the cholinium cation with deprotonated amino acid anions. We present a structural analysis of the liquid states of these compounds as revealed by accurate ab initio computations of the forces. We highlight the persistent structural motifs that see the ionic couple as the basic building block of the liquid whereby a strong hydrogen bonding network substantially determines the short range structural behavior of the bulk state. Other minor docking features of the interaction network are also discovered and described. Special cases along the series such as Cysteine and Phenylalanine are discussed in the view of their peculiar properties due to zwitterion formation and additional long-range structural organization.

  1. Causes and relevance of unsatisfactory and satisfactory but limited smears of liquid-based compared with conventional cervical cytology.

    Science.gov (United States)

    Siebers, Albertus G; Klinkhamer, Paul J J M; Vedder, Judith E M; Arbyn, Marc; Bulten, Johan

    2012-01-01

    Recent randomized controlled trials have shown a significant decrease in unsatisfactory rates for liquid-based cytology (LBC) compared with conventional Papanicolaou test (CP). The underlying causes and relevance of unsatisfactory results for LBC and CP have never been compared within the setting of a randomized controlled trial. To examine differences in causes and relevance of unsatisfactory and satisfactory but limited by (SBLB) results for LBC and CP. Data from the Netherlands ThinPrep Versus Conventional Cytology (NETHCON) trial were used, involving 89 784 women. Causes and relevance of unsatisfactory and SBLB results were analyzed. The primary cause for unsatisfactory results for CP and LBC was scant cellularity. Other causes for unsatisfactory CPs were virtually eliminated with LBC. The same was true for SBLB subcategories, with the exception of SBLB absence of transformation zone component and SBLB scant cellularity. The SBLB absence of transformation zone component showed a statistically significant 22% and SBLB scant cellularity a 12% nonsignificant increase with LBC. The detection rates of abnormalities found during 18 months of follow-up of unsatisfactory test results did not differ significantly between the 2 study arms, nor did they differ from the initial test positivity rates from the NETHCON trial. Liquid-based cytology shows an almost complete elimination of most causes for unsatisfactory CP, with scant cellularity remaining as the sole cause for unsatisfactory LBC. On the other hand, with LBC a significant increase of smears without a transformation zone component was noted. Women with an unsatisfactory test result are not at increased risk for cervical abnormalities either with LBC or with CP. Nederlands Trial Register, NTR1032, www.trialregister.nl .

  2. Liquid-Based Urine Cytology as a Tool for Detection of Human Papillomavirus, Mycoplasma spp., and Ureaplasma spp. in Men

    Science.gov (United States)

    Kawaguchi, Shohei; Shigehara, Kazuyoshi; Shimamura, Masayoshi; Nakashima, Takao; Sugimoto, Kazuhiro; Nakashima, Kazufumi; Furubayashi, Keiichi; Namiki, Mikio

    2012-01-01

    Liquid-based urine cytology (LB-URC) was evaluated for cytological diagnosis and detection of human papillomavirus (HPV), Mycoplasma, and Ureaplasma. Midstream urine samples were collected from 141 male patients with urethritis and 154 controls without urethritis, and sediment cells were preserved in liquid-based cytology solution. Urethral swabs from urethritis patients were tested for the presence of Neisseria gonorrhoeae and Chlamydia trachomatis. Papanicolaou tests were performed for cytological evaluation. HPV, Mycoplasma, and Ureaplasma genomes were determined by PCR-based methods, and localization of HPV DNA in urothelial cells was examined by in situ hybridization (ISH). The β-globin gene was positive in 97.9% of LB-URC samples from urethritis patients and in 97.4% of control samples, suggesting that high-quality cellular DNA was obtained from the LB-URC samples. HPV DNA was detected in 29 (21.0%) urethritis cases and in five (3.3%) controls (P Cytological evaluations could be performed for 92.1% of urethritis patients and 64.3% of controls. Morphological changes suggestive of HPV infection were seen in 20.7% of the HPV-positive samples, and ISH demonstrated the presence of HPV DNA in both squamous and urothelial cells in HPV-positive samples. Mycoplasma genitalium, Mycoplasma hominis, Ureaplasma parvum, and Ureaplasma urealyticum were detected in 14.5%, 10.9%, 6.5%, and 12.3% of urethritis patients, respectively. The prevalence rates of these microorganisms (except Ureaplasma parvum) were significantly higher in urethritis cases than controls (P < 0.05). LB-URC is applicable for detection of HPV, Mycoplasma, and Ureaplasma. HPV infection occurs in urothelial cells, especially in gonococcal urethritis. PMID:22135257

  3. Diagnostic accuracy of liquid-based endometrial cytology in the evaluation of endometrial pathology in postmenopausal women.

    Science.gov (United States)

    Remondi, C; Sesti, F; Bonanno, E; Pietropolli, A; Piccione, E

    2013-12-01

    The aim of this study was to compare liquid-based endometrial cytology with hysteroscopy and endometrial biopsy regarding its diagnostic accuracy in a series of postmenopausal women with abnormal uterine bleeding (AUB) or asymptomatic women with thickened endometrium assessed by transvaginal ultrasound as a screening procedure.   Inclusion criteria were: menopausal status; the presence of AUB and/or thickened endometrium assessed by ultrasound (cut-off 4 mm); a normal Papanicolaou (Pap) smear; and no adnexal pathology at ultrasound. Exclusion criteria were: previous endometrial pathology; and previous operative hysteroscopy. Of 768 postmenopausal women referred to our general gynaecology clinics, 121 fulfilled the inclusion criteria and were recruited to the trial. Twenty-one refused to participate. Cytological sampling was carried out by brushing the uterine cavity using the Endoflower device with no cervical dilation and the vial was processed using a ThinPrep® 2000 automated slide processor. The slides were stained using a Pap method.   In 98 cases with histological biopsies, endometrial cytology detected five cases of endometrial carcinoma, 10 of atypical hyperplasia and 47 of non-atypical hyperplasia; 36 cases were negative. In two cases cytology was inadequate because of uterine cervical stenosis. Taking atypical hyperplasia or worse as a positive test and outcome, the diagnostic accuracy of the endometrial cytology was 93.5%, with a sensitivity of 92% and specificity of 95%, a positive predictive value of 73% and a negative predictive value of 99%. All the carcinomas were detected by cytology. Only 42% of women with a positive diagnosis were symptomatic. The cytological sampling was well tolerated by all patients. No complication was registered.  Liquid-based endometrial cytology can be considered an useful diagnostic method in the detection of endometrial pathology as a first-line approach, particularly if associated with transvaginal ultrasound.

  4. A comparative analysis of conventional and SurePath liquid-based cervicovaginal cytology: A study of 140 cases

    Directory of Open Access Journals (Sweden)

    Jyotsna Sharma

    2016-01-01

    Full Text Available Background: The role of Papanicolaou (Pap test in cervical cancer screening need not be overemphasized. While most Western countries have adopted the liquid-based cytology (LBC, which is considered superior, many developing countries are still using the conventional Pap smear (CPS technique. Objective: To compare the staining and cytomorphological features on conventional versus liquid-based cervicovaginal smears. Materials and Methods: One hundred and forty cervicovaginal smears prepared by the standard conventional and LBC techniques were interpreted as per the Bethesda system of reporting cervicovaginal smears. Twelve parameters were studied, compared, and statistically analyzed. A P value <0.05 was considered to be statistically significant. Results: 129/140 (92% of CPSs and 130/140 (93% LBC smears were satisfactory. LBC had a significantly shorter screening time (2.0 ± 0.08 vs 4.0 ± 0.65 and better representative material than that of CPS (50% vs 42%. Neutrophils were significantly more in CPS than LBC (96% vs 92% with a P value <0.05 while hemorrhagic background and red blood cells (RBCs were more prominent in CPS. LBC showed significant artifactual changes in squamous epithelial cells. Epithelial abnormalities ranging from atypical squamous cells of undetermined significance (ASCUS to high grade squamous intraepithelial lesion (HSIL were seen in 3% (4 and 2% (2 of CPSs and LBCs, respectively. Organisms were better picked up in CPS (99% in CPS vs 73% LBC with a value of P = 0.0001. Conclusion: Although a shorter screening time and cleaner background are the major advantages of LBC, CPS is not inferior to LBC. Considering the high cost, rather than the advantages associated with LBC, we feel that CPS is a better option for developing countries.

  5. Automation-assisted cervical cancer screening in manual liquid-based cytology with hematoxylin and eosin staining.

    Science.gov (United States)

    Zhang, Ling; Kong, Hui; Ting Chin, Chien; Liu, Shaoxiong; Fan, Xinmin; Wang, Tianfu; Chen, Siping

    2014-03-01

    Current automation-assisted technologies for screening cervical cancer mainly rely on automated liquid-based cytology slides with proprietary stain. This is not a cost-efficient approach to be utilized in developing countries. In this article, we propose the first automation-assisted system to screen cervical cancer in manual liquid-based cytology (MLBC) slides with hematoxylin and eosin (H&E) stain, which is inexpensive and more applicable in developing countries. This system consists of three main modules: image acquisition, cell segmentation, and cell classification. First, an autofocusing scheme is proposed to find the global maximum of the focus curve by iteratively comparing image qualities of specific locations. On the autofocused images, the multiway graph cut (GC) is performed globally on the a* channel enhanced image to obtain cytoplasm segmentation. The nuclei, especially abnormal nuclei, are robustly segmented by using GC adaptively and locally. Two concave-based approaches are integrated to split the touching nuclei. To classify the segmented cells, features are selected and preprocessed to improve the sensitivity, and contextual and cytoplasm information are introduced to improve the specificity. Experiments on 26 consecutive image stacks demonstrated that the dynamic autofocusing accuracy was 2.06 μm. On 21 cervical cell images with nonideal imaging condition and pathology, our segmentation method achieved a 93% accuracy for cytoplasm, and a 87.3% F-measure for nuclei, both outperformed state of the art works in terms of accuracy. Additional clinical trials showed that both the sensitivity (88.1%) and the specificity (100%) of our system are satisfyingly high. These results proved the feasibility of automation-assisted cervical cancer screening in MLBC slides with H&E stain, which is highly desirable in community health centers and small hospitals.

  6. Accuracy of reading liquid based cytology slides using the ThinPrep Imager compared with conventional cytology: prospective study

    Science.gov (United States)

    d'Assuncao, Jefferson; Irwig, Les; Macaskill, Petra; Chan, Siew F; Richards, Adele; Farnsworth, Annabelle

    2007-01-01

    Objective To compare the accuracy of liquid based cytology using the computerised ThinPrep Imager with that of manually read conventional cytology. Design Prospective study. Setting Pathology laboratory in Sydney, Australia. Participants 55 164 split sample pairs (liquid based sample collected after conventional sample from one collection) from consecutive samples of women choosing both types of cytology and whose specimens were examined between August 2004 and June 2005. Main outcome measures Primary outcome was accuracy of slides for detecting squamous lesions. Secondary outcomes were rate of unsatisfactory slides, distribution of squamous cytological classifications, and accuracy of detecting glandular lesions. Results Fewer unsatisfactory slides were found for imager read cytology than for conventional cytology (1.8% v 3.1%; Pcytology (7.4% v 6.0% overall and 2.8% v 2.2% for cervical intraepithelial neoplasia of grade 1 or higher). Among 550 patients in whom imager read cytology was cervical intraepithelial neoplasia grade 1 or higher and conventional cytology was less severe than grade 1, 133 of 380 biopsy samples taken were high grade histology. Among 294 patients in whom imager read cytology was less severe than cervical intraepithelial neoplasia grade 1 and conventional cytology was grade 1 or higher, 62 of 210 biopsy samples taken were high grade histology. Imager read cytology therefore detected 71 more cases of high grade histology than did conventional cytology, resulting from 170 more biopsies. Similar results were found when one pathologist reread the slides, masked to cytology results. Conclusion The ThinPrep Imager detects 1.29 more cases of histological high grade squamous disease per 1000 women screened than conventional cytology, with cervical intraepithelial neoplasia grade 1 as the threshold for referral to colposcopy. More imager read slides than conventional slides were satisfactory for examination and more contained low grade cytological

  7. Preparation of A New Fiber by Sol-gel Technology in Solid-phase Microextraction (SPME)

    Institute of Scientific and Technical Information of China (English)

    Li Ming WEI; Qing Yu OU; Ju Bai LI

    2004-01-01

    The sol-gel technology is applied for the preparation of solid-phase microextraction (SPME) fiber. The fiber demonstrates high thermal stability, efficient extraction rate and the selectivity for non-polar or low-polar analytes. Efficient SPME-GC-FID analyses of benzene- toluene-ethylbenzene-xylenes (BTEXs) and low-polar halocarbon were achieved by the sol-gel coated DSDA-DDBT-TiO2 fiber. Some parameters of the SPME fiber for the determination of halocarbon in aqueous sample were investigated.

  8. Solid-phase microextraction for flavor analysis in Harari Khat (Catha edulis) stimulant

    Institute of Scientific and Technical Information of China (English)

    AL-FLAHIAbdulsalam; 邹建凯; 殷学锋

    2004-01-01

    This research examined the typical flavor compounds in the commonest type of Khat called Harari Khat grown in the region of Ethiopia.Twenty-eight compounds, which includes 1,2-Propanedione,1-Phenyl,Hexanol,Hexanal compounds,Limonene, Benzaldehyde with other flavors, were extracted by polydimethylsiloxane at room temperature for 30min from Khat samples,and identified by solid-phase microextraction-gas chromatography-mass spectrometry (SPME-GC-MS).This method needs no organic solvents and required minimal sample.

  9. Spectrophotometric determination of Sudan Blue II in environmental samples after dispersive liquid-liquid microextraction

    Directory of Open Access Journals (Sweden)

    Yunus Emre Unsal

    2014-01-01

    Full Text Available A dispersive liquid-liquid microextraction procedure coupled to spectrophotometry is described for the determination of the trace levels of Sudan Blue II. Analytical parameters, such as pH, volume of extraction solvent (carbon tetrachloride, volume of dispersant (ethanol, volume of sample, and extraction time, were optimized. Matrix effects were also investigated. Preconcentration factor was found to be 200. Detection limit and relative standard deviation (RSD were 0.55 µg L-1 and 3.9%, respectively. The procedure was successfully used for the determination of trace levels of Sudan Blue II in food, ink, antifreeze, and industrial waste-water samples.

  10. Liquid-phase microextraction for simultaneous chromatographic analysis of three antidepressant drugs in plasma

    Directory of Open Access Journals (Sweden)

    Carlos Eduardo Dobrovolskni Porto

    2012-01-01

    Full Text Available A method using Liquid Phase Microextraction for simultaneous detection of citalopram (CIT, paroxetine (PAR and fluoxetine (FLU, using venlafaxine as internal standard, in plasma by high performance liquid chromatography with fluorescence detection was developed. The linearity was evaluated between 5.0 and 500 ng mL-1 (r > 0.99 and the limit of quantification was 2.0, 3.0 and 5.0 ng mL-1 for CIT, PAR and FLU, respectively. Therefore, it can be applied to therapeutic drug monitoring, pharmacokinetics or bioavailability studies and its advantages are that it necessary relatively inexpensive equipment and sample preparation techniques.

  11. Screening of Brazilian fruit aromas using solid-phase microextraction-gas chromatography-mass spectrometry.

    Science.gov (United States)

    Augusto, F; Valente, A L; dos Santos Tada, E; Rivellino, S R

    2000-03-17

    Manual headspace solid-phase microextraction (SPME) coupled to gas chromatography-mass spectrometry (GC-MS) was used for the qualitative analysis of the aromas of four native Brazilian fruits: cupuassu (Theobroma grandiflorum, Spreng.), cajá (Spondias lutea. L.), siriguela (Spondias purpurea, L.) and graviola (Anona reticulata, L). Industrialized pulps of these fruits were used as samples, and extractions with SPME fibers coated with polydimethylsiloxane, polyacrylate, Carbowax and Carboxen were carried out. The analytes identified included several alcohols, esters, carbonyl compounds and terpernoids. The highest amounts extracted, evaluated from the sum of peak areas, were achieved using the Carboxen fiber.

  12. SIMPLE EXTRACTION OF GAMMA-HYDROXYBUTYRATE IN HUMAN WHOLE BLOOD BY HEADSPACE SOLID-PHASE MICROEXTRACTION

    OpenAIRE

    2001-01-01

    We have developed a simple method for the extraction of gamma-hydroxybutyrate (GHB) in human whole blood using headspace solid-phase microextraction (SPME). The procedure involves the conversion of GHB to gamma-butyrolactone (GBL) with acid catalysis; gamma-valerolactone (GVL) was used as internal standard (IS). After heating a vial containing a whole blood sample with GHB and IS at 80℃ for 5 min in the presence of H3PO4 solution, a Carboxen/polydimethylsiloxane -coated fiber was exposed to t...

  13. Liquid Phase Micro-Extraction of Linear Alkylbenzene Sulfonate Anionic Surfactants in Aqueous Samples

    OpenAIRE

    2011-01-01

    Hollow fiber liquid phase micro-extraction (LPME) of linear alkylbenzene sulfonates (LAS) from aqueous samples was studied. Ion pair extraction of C10, C11, C12 and C13 homologues was facilitated with trihexylamine as ion-pairing agent, using di-n-hexylether as solvent for the supported liquid membrane (SLM). Effects of extraction time, acceptor buffer concentration, stirring speed, sample volume, NaCl and humic acids were studied. At 10–50 μg L−1 linear R2-coefficients were 0.99 for C10 and ...

  14. Age-specific patterns of unsatisfactory results for conventional Pap smears and liquid-based cytology: data from two randomised clinical trials.

    NARCIS (Netherlands)

    Castle, P.E.; Bulten, J.; Confortini, M.; Klinkhamer, P.; Pellegrini, A.; Siebers, A.G.; Ronco, G.; Arbyn, M.

    2010-01-01

    OBJECTIVE: To investigate the rate of unsatisfactory cervical cell samples in liquid-based cytology (LBC) versus conventional cytology (CC) by age. DESIGN: Randomised clinical trials. SETTING: Population-based cervical cancer screening in the Netherlands and Italy. POPULATION: Asymptomatic women inv

  15. Age-specific patterns of unsatisfactory results for conventional Pap smears and liquid-based cytology: data from two randomised clinical trials.

    NARCIS (Netherlands)

    Castle, P.E.; Bulten, J.; Confortini, M.; Klinkhamer, P.; Pellegrini, A.; Siebers, A.G.; Ronco, G.; Arbyn, M.

    2010-01-01

    OBJECTIVE: To investigate the rate of unsatisfactory cervical cell samples in liquid-based cytology (LBC) versus conventional cytology (CC) by age. DESIGN: Randomised clinical trials. SETTING: Population-based cervical cancer screening in the Netherlands and Italy. POPULATION: Asymptomatic women inv

  16. Liquid-based cervical cytology using ThinPrep technology: weighing the pros and cons in a cost-effectiveness analysis.

    NARCIS (Netherlands)

    Bekker-Grob, E.W. de; Kok, I.M. de; Bulten, J.; Rosmalen, J. van; Vedder, J.E.M.; Arbyn, M.; Klinkhamer, P.J.; Siebers, A.G.; Ballegooijen, M. van

    2012-01-01

    PURPOSE: Cervical cancer screening with liquid-based cytology (LBC) has been developed as an alternative to the conventional Papanicolaou (CP) smear. Cost-effectiveness is one of the issues when evaluating LBC. Based on the results of a Dutch randomised controlled trial, we conducted cost-effectiven

  17. Accuracy of a Low Priced Liquid-Based Method for Cervical Cytology in 632 Women Referred for Colposcopy After a Positive Pap Smear

    NARCIS (Netherlands)

    van Hemel, B. M.; Buikema, H. J.; Groen, H.; Suurmeijer, A. J. H.

    2009-01-01

    The aim of this quality controlling study was to determine the accuracy of liquid-based cytology (LBC) with the Turbitec (R) cytocentrifuge technique. Cervical smears of 632 Women, Who were referred to our CIN outpatient department, after at least two smears with ASCUS or higher were evaluated and c

  18. Comparison of conventional Papanicolaou smear and SurePath® liquid-based cytology in the Copenhagen population screening programme for cervical cancer

    DEFF Research Database (Denmark)

    Kirschner, Benny; Simonsen, Kåre; Junge, Jette

    2006-01-01

    OBJECTIVE: To compare diagnostic performance of conventional Papanicolaou smear with SurePath liquid-based cytology in a population screening programme. METHODS: A retrospective comparison was performed on data from two 18-month periods of the screening programme for cervical cancer...

  19. Accuracy of a Low Priced Liquid-Based Method for Cervical Cytology in 632 Women Referred for Colposcopy After a Positive Pap Smear

    NARCIS (Netherlands)

    van Hemel, B. M.; Buikema, H. J.; Groen, H.; Suurmeijer, A. J. H.

    2009-01-01

    The aim of this quality controlling study was to determine the accuracy of liquid-based cytology (LBC) with the Turbitec (R) cytocentrifuge technique. Cervical smears of 632 Women, Who were referred to our CIN outpatient department, after at least two smears with ASCUS or higher were evaluated and c

  20. Liquid-based cervical cytology using ThinPrep technology: weighing the pros and cons in a cost-effectiveness analysis.

    NARCIS (Netherlands)

    Bekker-Grob, E.W. de; Kok, I.M. de; Bulten, J.; Rosmalen, J. van; Vedder, J.E.M.; Arbyn, M.; Klinkhamer, P.J.; Siebers, A.G.; Ballegooijen, M. van

    2012-01-01

    PURPOSE: Cervical cancer screening with liquid-based cytology (LBC) has been developed as an alternative to the conventional Papanicolaou (CP) smear. Cost-effectiveness is one of the issues when evaluating LBC. Based on the results of a Dutch randomised controlled trial, we conducted cost-effectiven

  1. Ultrasound-assisted magnetic dispersive solid-phase microextraction: A novel approach for the rapid and efficient microextraction of naproxen and ibuprofen employing experimental design with high-performance liquid chromatography.

    Science.gov (United States)

    Ghorbani, Mahdi; Chamsaz, Mahmoud; Rounaghi, Gholam Hossein

    2016-03-01

    A simple, rapid, and sensitive method for the determination of naproxen and ibuprofen in complex biological and water matrices (cow milk, human urine, river, and well water samples) has been developed using ultrasound-assisted magnetic dispersive solid-phase microextraction. Magnetic ethylendiamine-functionalized graphene oxide nanocomposite was synthesized and used as a novel adsorbent for the microextraction process and showed great adsorptive ability toward these analytes. Different parameters affecting the microextraction were optimized with the aid of the experimental design approach. A Plackett-Burman screening design was used to study the main variables affecting the microextraction process, and the Box-Behnken optimization design was used to optimize the previously selected variables for extraction of naproxen and ibuprofen. The optimized technique provides good repeatability (relative standard deviations of the intraday precision 3.1 and 3.3, interday precision of 5.6 and 6.1%), linearity (0.1-500 and 0.3-650 ng/mL), low limits of detection (0.03 and 0.1 ng/mL), and a high enrichment factor (168 and 146) for naproxen and ibuprofen, respectively. The proposed method can be successfully applied in routine analysis for determination of naproxen and ibuprofen in cow milk, human urine, and real water samples.

  2. Comparable performance of conventional and liquid-based cytology in diagnosing anal intraepithelial neoplasia in HIV-infected and -uninfected Thai men who have sex with men.

    Science.gov (United States)

    Phanuphak, Nittaya; Teeratakulpisarn, Nipat; Lim, Cherry; Changnam, Taweesak; Kerr, Stephen; Deesua, Amornrat; Hongchookiat, Piranun; Rodbamrung, Piyanee; Numto, Saranya; Barisri, Jiranuwat; Phanuphak, Praphan; Keelawat, Somboon; Sohn, Annette H; Ananworanich, Jintanat; Triratanachat, Surang

    2013-08-01

    Anal cytology has increasingly been used to screen for anal intraepithelial neoplasia (AIN) among men who have sex with men (MSM) at increased risk for anal cancer. Use of liquid-based cytology has been reported to reduce fecal and bacterial contamination and air-drying artifact compared with conventional cytology. Costs associated with liquid-based cytology, however, may limit its use in resource-limited settings. Anal swab samples were collected from MSM participants and used to prepare conventional and liquid-based cytology slides. Abnormal conventional cytology results triggered referral for high-resolution anoscopy and biopsy. Agreement between the 2 cytology techniques and the positive predictive value ratios of histology confirmed AIN were calculated. Among 173 MSM, abnormal anal cytology was identified in 46.2% of conventional and 32.4% of liquid-based slides. The results agreed in 62.4% of cases with a κ value of 0.49 (P cytology results (95% confidence interval: 1.6 to 7.8; P = 0.001) compared with HIV-uninfected MSM. Histological AIN 2 and 3 were identified in 20 MSM. The positive predictive value ratios and 95% confidence interval indicated no difference between the 2 techniques. Conventional anal cytology may be a preferred option for resource-limited settings given comparable performances to liquid-based cytology for the detection of AIN, although the agreement between the 2 techniques was lower among HIV-infected MSM. Due to high prevalence of abnormal anal cytology and AIN, health systems should prepare adequate infrastructure for high-resolution anoscopy services and AIN treatment.

  3. Development of optimal liquid based cytology sample processing methods for HPV testing: minimising the 'inadequate' test result.

    Science.gov (United States)

    Peevor, R; Jones, J; Fiander, A N; Hibbitts, S

    2011-05-01

    Incorporation of HPV testing into cervical screening is anticipated and robust methods for DNA extraction from liquid based cytology (LBC) samples are required. This study compared QIAamp extraction with Proteinase K digestion and developed methods to address DNA extraction failure (β-globin PCR negative) from clinical specimens. Proteinase K and QIAamp extraction methods in paired LBC samples were comparable with adequate DNA retrieved from 93.3% of clinical specimens. An HPV prevalence cohort (n=10,000) found 7% (n=676) LBC samples tested negative for β-globin, and were classified as inadequate. This 'failure' rate is unsuitable for population screening, particularly as the sampling method is intrusive. 379/676 samples were assessed to determine the cause of test failure. Re-testing confirmed adequate DNA in 21.6% of the original extracts; re-extraction from stored material identified 56.2% samples contained adequate material; dilution to overcome sample inhibition (1:10) resolved 51.7% cases in original extracts and 28% in new extracts. A standardised approach to HPV testing with an optimal DNA concentration input rather than standard volume input is recommended. Samples failing initial DNA extraction should be repeat extracted and assessed for sample inhibition to reduce the 7% of HPV tests being reported as inadequate and reduce the need for retesting of those women to <1%.

  4. Comparison of specimen adequacy and smear quality in oral smears prepared by manual liquid-based cytology and conventional methods

    Directory of Open Access Journals (Sweden)

    Surabhi Shukla

    2015-01-01

    Full Text Available Background: Liquid-based cytology (LBC, recommended in the mass screening of potentially malignant cervical and oral lesions, suffers from high cost owing to the use of expensive automated devices and materials. Considering the need for cost-effective LBC techniques, we evaluated the efficacy of an inexpensive manual LBC (MLBC technique against conventional cytological technique in terms of specimen adequacy and smear quality of oral smears. Materials and Methods: Cytological samples were collected from 21 patients using a cytobrush device. After preparation of a conventional smear, the brush containing the remaining sample was immersed in the preservative vial. The preserved material was processed by an MLBC technique and subsequently, direct smears were made from the prepared cell button. Both conventional and MLBC smears were stained by routine Papanicolaou technique and evaluated by an independent observer for the thickness of the smear, cellular distribution, resolution/clarity of cells, cellular staining characteristics and the presence of unsatisfactory background/artifacts. Each parameter was graded as satisfactory; or satisfactory, but limited; or unsatisfactory. Chi-square test was used to compare the values obtained (significance set at P ≤ 0.05. Results: MLBC technique produced a significant number of satisfactory smears with regard to cell distribution, clarity/resolution, staining characteristics and background/artifacts compared to conventional methods. Conclusions: MLBC is a cost-effective cytological technique that may produce oral smears with excellent cytomorphology and longer storage life.

  5. Liquid-based cytology improves preoperative diagnostic accuracy of the tall cell variant of papillary thyroid carcinoma.

    Science.gov (United States)

    Lee, Sung Hak; Jung, Chan Kwon; Bae, Ja Seong; Jung, So Lyung; Choi, Yeong Jin; Kang, Chang Suk

    2014-01-01

    The tall cell variant (TCV) of papillary thyroid carcinoma (PTC) is the most common among the aggressive variants of the disease. We aimed to investigate the clinicopathologic characteristics of TCV, and evaluate the diagnostic efficacy of liquid-based cytology (LBC) in TCV detection compared with conventional smear in thyroid fine needle aspiration (FNA). A total of 266 consecutive patients (220 women and 46 men) with PTC were enrolled. We analyzed tumor characteristics according to histologic growth patterns as classic, classic PTC with tall cell features, and TCV. The cytomorphologic features of these subtypes were investigated according to the preparation methods of conventional smear and LBC. TCV and classic PTC with tall cell features comprised 4.9% and 6.0% of all tumors, respectively, and were significantly associated with older age at presentation, larger tumor size, high frequency of extrathyroid extension, and BRAF mutation in comparison with classic PTC. However, there was no statistically significant difference in clinicopathologic features between TCV and classic PTC with tall cell features. Tall cells were more easily detected by LBC than by conventional smear. The percentage of tall cells identified using LBC was well correlated with three histologic subtypes. Our results demonstrate that TCV is more common than previously recognized in Korea and any PTC containing tall cells may have identical biological behavior regardless of the precise proportions of tall cells. It is possible to make a preoperative diagnosis of TCV using LBC.

  6. Liquid-based cytology versus conventional cytology for evaluation of cervical Pap smears: Experience from the first 1000 split samples

    Directory of Open Access Journals (Sweden)

    Vikrant Bhar Singh

    2015-01-01

    Full Text Available Context and Aim: Screening programs using conventional cytology conventional Pap smear (CPS have successfully reduced cervical cancer, but newer tests like liquid-based cytology (LBC and human papillomavirus testing might enhance screening. The main aim of the present study was to assess the diagnostic accuracy of LBC versus CPS using "split samples." Materials and Methods: This was a prospective study comprising of 1000 consecutive cervical "split samples" over a period of 1 year. Split sample was obtained using cervex-brush. CPS was prepared from the brush and the brush head was suspended in the LBC vial and processed by SurePath™ LBC. Results: There were 4.3% unsatisfactory (U/S cases in CPS and 1.7% in LBC; the main cause is insufficient cells, and excess of blood in CPS. About 25/100 (2.5% split samples had epithelial abnormalities both in CPS and LBC (1.2%-atypical squamous cells of undetermined significance; 0.4%-low grade squamous intraepithelial lesion; 0.2%-high grade squamous intraepithelial lesion; 0.5%-squamous cell carcinoma; 0.1%-atypical glandular cells favouring neoplasia; 0.2%-adenocarcinoma. Inflammatory organisms were almost equally identified in both techniques but were better seen in LBC samples. Conclusions: LBC technique leads to significant reduction of U/S rate. LBC samples offered better clarity, uniform spread of smears, less time for screening and better handling of hemorrhagic and inflammatory samples. LBC had equivalent sensitivity and specificity to CPS.

  7. Utility of manual liquid-based cytology and conventional smears in the evaluation of various fine-needle aspiration samples

    Directory of Open Access Journals (Sweden)

    P Arul

    2016-01-01

    Full Text Available Background: Liquid-based cytology (LBC preparation is a way to improve and refine the fine-needle aspiration (FNA samples. There are a few studies comparing LBC with conventional smear (CS. Aim: The present study was undertaken to evaluate the utility of manual LBC (MLBC and CS preparations in various FNA samples. Materials and Methods: In this cross-sectional study, a total of 100 FNA samples from various anatomical sites were evaluated using MLBC and CS preparations. Cellularity, blood, informative background, monolayers, cell architecture, cytoplasmic, and nuclear preservation were compared with MLBC and CS preparations by Wilcoxon signed rank test. P < 0.05 is considered statistically significant. Results: MLBC preparations were superior to CS preparations in view of absence of blood and debris (P = 0.001, presence of monolayers (P < 0.001, and preservation of cytoplasmic (P = 0.001 and nuclear details (P = 0.001. However, no statistically significant differences were found between MLBC and CS preparations with regard to cellularity (P = 0.157, informative background (P = 0.083, and architecture (P = 0.739. Conclusion: MLBC preparations in FNAC are a safe, easy, and less time-consuming procedure, and it may have promising diagnostic value in the evaluation of FNA samples from various anatomical sites. However, the use of both MLBC and CS preparations is recommended to achieve optimal diagnostic yield.

  8. A novel method: ionic liquid-based ultrasound-assisted extraction of polyphenols from Chinese purple yam.

    Science.gov (United States)

    Zhang, Junhong; Zong, Aizhen; Xu, Tongcheng; Zhan, Ping; Liu, Lina; Qiu, Bin; Liu, Wei; Jia, Min; Du, Fangling; Tian, Honglei

    2017-08-24

    Chinese purple yam is famous for therapeutic and nutritional values in lowering blood glucose, blood pressure and even preventing and treating cardiovascular diseases. However, traditional extraction techniques for the functional polyphenolic compounds mostly utilise unfriendly organic solvent and easily cause degradation of polyphenols. In this study, a novel ionic liquid-based ultrasound-assisted extraction (IL-UAE) technique was utilised to obtain polyphenols. The optimal extraction condition included: solid-liquid ratio (0.05 g/mL), ionic liquid concentration (1.05 M), extraction temperature (67°C) and ultrasonic time (37 min). The maximum free radical scavenging activity (86.21%) and total antioxidant activity (2.21 mM) were achieved and matched well with the predicted values, superior to that of the extract from regular ethanol-based UAE. IL-UAE could be a rapid and green technique for efficient extraction of polyphenols from purple yam with low solvent consumption and few structural deterioration, exhibiting application potential in food and pharmaceutical industries.

  9. Molecular Diagnosis Using Residual Liquid-Based Cytology Materials for Patients with Nondiagnostic or Indeterminate Thyroid Nodules.

    Science.gov (United States)

    Kwon, Hyemi; Kim, Won Gu; Eszlinger, Markus; Paschke, Ralf; Song, Dong Eun; Kim, Mijin; Park, Suyeon; Jeon, Min Ji; Kim, Tae Yong; Shong, Young Kee; Kim, Won Bae

    2016-12-01

    Molecular analysis for common somatic mutations in thyroid cancer can improve diagnostic accuracy of fine-needle aspiration cytology (FNAC) in the nondiagnostic or indeterminate category of thyroid nodules. In this study, we evaluated the feasibility of molecular diagnosis from residual liquid-based cytology (LBC) material after cytological diagnosis. This prospective study enrolled 53 patients with thyroid nodules diagnosed as nondiagnostic, atypia of undetermined significance (AUS), or follicular lesion of undetermined significance (FLUS) after FNAC. DNAs and RNAs were isolated from residual LBC materials. BRAF(V600E) and RAS point mutations, PAX8/peroxisome proliferator-activated receptor γ (PPARγ), RET/PTC1, and RET/PTC3 rearrangements were evaluated by real-time polymerase chain reaction and pyrosequencing. All DNAs from 53 residual LBC samples could be analysed and point mutations were detected in 10 samples (19%). In 17 AUS nodules, seven samples (41%) had point mutations including BRAF (n=4), NRAS (n=2), and KRAS (n=1). In 20 FLUS nodules, three samples (15%) had NRAS point mutations. RNA from only one FLUS nodule could be analysed for rearrangements and there was no abnormality. Molecular analysis for BRAF and RAS mutations was feasible in residual LBC materials and might be useful for diagnosis of indeterminate thyroid nodules.

  10. Comparison of Unsatisfactory Samples from Conventional Smear versus Liquid-Based Cytology in Uterine Cervical Cancer Screening Test.

    Science.gov (United States)

    Jeong, Hoiseon; Hong, Sung Ran; Chae, Seoung-Wan; Jin, So-Young; Yoon, Hye Kyoung; Lee, Juhie; Kim, Eun Kyung; Ha, Sook Tai; Kim, Sung Nam; Park, Eun-Jung; Jung, Jong Jae; Sung, Sun Hee; Lim, Sung-Chul

    2017-05-01

    Cervical cytology for uterine cervical cancer screening has transitioned from conventional smear (CS) to liquid-based cytology (LBC), which has many advantages. The aim of this study was to compare the proportion of unsatisfactory specimens from CS versus LBC at multiple institutions including general hospitals and commercial laboratories. Each participating institution provided a minimum of 500 Papanicolaou (Pap) test results for analysis. Pap tests were classified according to the participating institution (commercial laboratory or general hospital) and the processing method (CS, ThinPrep, SurePath, or CellPrep). The causes of unsatisfactory results were classified as technical problems, scant cellularity, or complete obscuring factors. A total of 38,956 Pap test results from eight general hospitals and three commercial laboratories were analyzed. The mean unsatisfactory rate of LBC was significantly lower than that of CS (1.26% and 3.31%, p = .018). In the LBC method, samples from general hospitals had lower unsatisfactory rates than those from commercial laboratories (0.65% vs 2.89%, p = .006). The reasons for unsatisfactory results were heterogeneous in CS. On the other hand, 66.2% of unsatisfactory results in LBC were due to the scant cellularity. Unsatisfactory rate of cervical cancer screening test results varies according to the institution and the processing method. LBC has a significantly lower unsatisfactory rate than CS.

  11. Value of centrifugated liquid-based cytology by Papanicolaou and May-Grünwald in oral epithelial cells

    Science.gov (United States)

    Ahmed, Hussain Gadelkarim; Edris, Ali Mahmmoud; Mohmed, Eneel Ahmed; Hussein, Mohammed Omer M

    2009-01-01

    For many years, liquid-based cytology (LBC) has been developed for cervical cancer screening and not oral cancer, as it requires automated devices. The aim of this study was to compare the utility of centrifugated CLBC preparation with that of direct preparation in oral lesions, by Papanicolaou (Pap) and May Grünwald-Giemsa's (MGG) methods. A total of 100 consecutive cases of oral lesions were investigated. We compared the results obtained by the CLBC performed by cytocentrifugation with those obtained by direct smear applying Pap and MGG methods. The comparison between CLBC and direct smears was based on the thickening or adequacy of the smear, distribution of cells and staining quality. All smears in CLBC and direct preparation were found adequate. For thickness of the smear, 40% and 42% were excellent, 33% and 30% were good, and 27% and 28% were acceptable by LBC and direct preparation, respectively. For the distribution of cells and scantiness of background elements, 92 (92%) smears of the CLBC have revealed clear, well distributed smears, compared to 70 (70%) of those in direct preparation. For the staining quality with the Pap method, 39% and 69% were excellent staining quality, 25% and 20% were good, and 36% and 11% were acceptable for CLBC and direct preparation, respectively. In MGG method, 9% and 22% were excellent staining quality, 23% and 36% were good and 68% and 43% were acceptable for CLBC and direct preparation respectively. CLBC performed by cytocentrifugation is inexpensive, and reduces inadequate smears and background staining. PMID:21139883

  12. Application of liquid-based cytology preparation in micronucleus assay of exfoliated buccal epithelial cells in road construction workers

    Directory of Open Access Journals (Sweden)

    P Arul

    2017-01-01

    Full Text Available Background: Asphalts are bitumens that consist of complex of hydrocarbon mixtures and it is used mainly in road construction and maintenance. Aim: This study was undertaken to evaluate the micronucleus (MN assay of exfoliated buccal epithelial cells in road construction workers using liquid-based cytology (LBC preparation. Materials and Methods: Three different stains (May–Grunwald Giemsa, hematoxylin and eosin, and Papanicolaou were used to evaluate the frequency of MN in exfoliated buccal epithelial of 100 participants (fifty road construction workers and fifty administrative staff using LBC preparation. Statistical analysis was performed with Student's t-test, and P< 0.05 was considered statistically significant. Results: The mean frequency of MN for cases was significantly higher than that of controls (P = 0.001 regardless of staining method used and also cases with exposure period of more than 5 years had statistically significant difference (P < 0.05 than cases with < 5 years of exposure. Conclusion: The present study concluded that workers exposed to asphalts during road construction exhibit a higher frequency of MN in exfoliated buccal epithelial cells and they are under the significant risk of cytogenetic damage. LBC preparation has potential application for the evaluation of frequency of MN. This technique may be advocated in those who are occupationally exposed to potentially carcinogenic agents in view of improvement in the smear quality and visualization of cell morphology.

  13. Utility of manual liquid-based cytology and conventional smears in the evaluation of various fine-needle aspiration samples.

    Science.gov (United States)

    Arul, P

    2016-01-01

    Liquid-based cytology (LBC) preparation is a way to improve and refine the fine-needle aspiration (FNA) samples. There are a few studies comparing LBC with conventional smear (CS). The present study was undertaken to evaluate the utility of manual LBC (MLBC) and CS preparations in various FNA samples. In this cross-sectional study, a total of 100 FNA samples from various anatomical sites were evaluated using MLBC and CS preparations. Cellularity, blood, informative background, monolayers, cell architecture, cytoplasmic, and nuclear preservation were compared with MLBC and CS preparations by Wilcoxon signed rank test. P < 0.05 is considered statistically significant. MLBC preparations were superior to CS preparations in view of absence of blood and debris (P = 0.001), presence of monolayers (P < 0.001), and preservation of cytoplasmic (P = 0.001) and nuclear details (P = 0.001). However, no statistically significant differences were found between MLBC and CS preparations with regard to cellularity (P = 0.157), informative background (P = 0.083), and architecture (P = 0.739). MLBC preparations in FNAC are a safe, easy, and less time-consuming procedure, and it may have promising diagnostic value in the evaluation of FNA samples from various anatomical sites. However, the use of both MLBC and CS preparations is recommended to achieve optimal diagnostic yield.

  14. Preliminary study of a new, fully automated system for liquid-based cytology: the NovaPrep® processor system.

    Science.gov (United States)

    Esquivias López-Cuervo, Javier; Montalbán Beltran, Estanislao; Cuadros Lopez, Jose Luis; Alonso Castillo, Angeles; Nieto Sanchez, Teresa

    2011-01-01

    To evaluate a fully automated system for liquid-based cytology (LBC): the NovaPrep® Processor System (NPS), which is based on the new concept of double decantation, versus conventional cytology (CC), the gold standard for cytology. We performed a preliminary comparative study involving 1,129 female patients who underwent sampling for a Pap test; the sample was first smeared for CC and then, using the remaining specimen on the brush, for LBC with the NPS. The performances of CC and NPS were evaluated for accuracy and compared using the gold standard of a combination of one of the two methods of pathological cytology with screening for positive human papilloma virus, quantification of cells (normal and pathological), and improvement in the quality of samples and reading time. The results showed improvement in sensitivity (3.81% for CC vs. 4.52% for NPS) with a specificity superior to 90% for both, a markedly decreased number of unsatisfactory specimens, notably samples containing too many inflamed cells (7.4% for CC vs. 0.5% for NPS), and a shortening of the reading time, which was three times less using NPS. This preliminary study showed a gain in sensitivity, a drop in the number of unsatisfactory specimens and a reduction in reading time with NPS. The results achieved using this fully automated LBC procedure are very promising and will hopefully reduce the overall cost of cervical cancer screening in the future. Copyright © 2011 S. Karger AG, Basel.

  15. Comparison of specimen adequacy and smear quality in oral smears prepared by manual liquid-based cytology and conventional methods.

    Science.gov (United States)

    Shukla, Surabhi; Einstein, A; Shukla, Abhilasha; Mishra, Deepika

    2015-01-01

    Liquid-based cytology (LBC), recommended in the mass screening of potentially malignant cervical and oral lesions, suffers from high cost owing to the use of expensive automated devices and materials. Considering the need for cost-effective LBC techniques, we evaluated the efficacy of an inexpensive manual LBC (MLBC) technique against conventional cytological technique in terms of specimen adequacy and smear quality of oral smears. Cytological samples were collected from 21 patients using a cytobrush device. After preparation of a conventional smear, the brush containing the remaining sample was immersed in the preservative vial. The preserved material was processed by an MLBC technique and subsequently, direct smears were made from the prepared cell button. Both conventional and MLBC smears were stained by routine Papanicolaou technique and evaluated by an independent observer for the thickness of the smear, cellular distribution, resolution/clarity of cells, cellular staining characteristics and the presence of unsatisfactory background/artifacts. Each parameter was graded as satisfactory; or satisfactory, but limited; or unsatisfactory. Chi-square test was used to compare the values obtained (significance set at P ≤ 0.05). MLBC technique produced a significant number of satisfactory smears with regard to cell distribution, clarity/resolution, staining characteristics and background/artifacts compared to conventional methods. MLBC is a cost-effective cytological technique that may produce oral smears with excellent cytomorphology and longer storage life.

  16. Performance of microarray and liquid based capture methods for target enrichment for massively parallel sequencing and SNP discovery.

    Directory of Open Access Journals (Sweden)

    Anna Kiialainen

    Full Text Available Targeted sequencing is a cost-efficient way to obtain answers to biological questions in many projects, but the choice of the enrichment method to use can be difficult. In this study we compared two hybridization methods for target enrichment for massively parallel sequencing and single nucleotide polymorphism (SNP discovery, namely Nimblegen sequence capture arrays and the SureSelect liquid-based hybrid capture system. We prepared sequencing libraries from three HapMap samples using both methods, sequenced the libraries on the Illumina Genome Analyzer, mapped the sequencing reads back to the genome, and called variants in the sequences. 74-75% of the sequence reads originated from the targeted region in the SureSelect libraries and 41-67% in the Nimblegen libraries. We could sequence up to 99.9% and 99.5% of the regions targeted by capture probes from the SureSelect libraries and from the Nimblegen libraries, respectively. The Nimblegen probes covered 0.6 Mb more of the original 3.1 Mb target region than the SureSelect probes. In each sample, we called more SNPs and detected more novel SNPs from the libraries that were prepared using the Nimblegen method. Thus the Nimblegen method gave better results when judged by the number of SNPs called, but this came at the cost of more over-sampling.

  17. Ionic liquid-based aqueous biphasic systems as a versatile tool for the recovery of antioxidant compounds.

    Science.gov (United States)

    Santos, João H; e Silva, Francisca A; Ventura, Sónia P M; Coutinho, João A P; de Souza, Ranyere L; Soares, Cleide M F; Lima, Álvaro S

    2015-01-01

    The comparative evaluation of distinct types of ionic liquid-based aqueous biphasic systems (IL-ABS) and more conventional polymer/salt-based ABS to the extraction of two antioxidants, eugenol and propyl gallate, is focused. In a first approach, IL-ABS composed of ILs and potassium citrate (C6H5K3O7/C6H8O7) buffer at pH 7 were applied to the extraction of two antioxidants, enabling the assessment of the impact of IL cation core on the extraction. The second approach uses ABS composed of polyethylene glycol (PEG) and potassium phosphate (K2HPO4/KH2PO4) buffer at pH 7 with imidazolium-based ILs as adjuvants. Their application to the extraction of the compounds allowed the investigation of the impact of the presence/absence of IL, the PEG molecular weight, and the alkyl side chain length of the imidazolium cation on the partition. It is possible to maximize the extractive performance of both antioxidants up to 100% using both types of IL-ABS. The IL enhances the performance of ABS technology. The data puts in evidence the pivotal role of the appropriate selection of the ABS components and design to develop a successful extractive process, from both environmental and performance points of view.

  18. Ionic-liquid-based proton conducting membranes for anhydrous H2/Cl2 fuel-cell applications.

    Science.gov (United States)

    Liu, Sa; Zhou, Li; Wang, Pengjie; Zhang, Fangfang; Yu, Shuchun; Shao, Zhigang; Yi, Baolian

    2014-03-12

    An ionic-liquid-doped poly(benzimidazole) (PBI) proton-conducting membrane for an anhydrous H2/Cl2 fuel cell has been proposed. Compared with other ionic liquids, such as imidazole-type ionic liquids, diethylmethylammonium trifluoromethanesulfonate ([dema][TfO]) showed better electrode reaction kinetics (H2 oxidation and Cl2 reduction reaction at platinum) and was more suitable for a H2/Cl2 fuel cell. PBI polymer and [dema][TfO] were compatible with each other, and the hybrid membranes exhibited high stability and good ionic conductivity, reaching 20.73 mS cm(-1) at 160 °C. We also analyzed the proton-transfer mechanism in this ionic-liquid-based membrane and considered that both proton-hopping and diffusion mechanisms existed. In addition, this composite electrolyte worked well in a H2/Cl2 fuel cell under non-water conditions. This work would give a good path to study the novel membranes for anhydrous H2/Cl2 fuel-cell application.

  19. Comparison of specimen adequacy and smear quality in oral smears prepared by manual liquid-based cytology and conventional methods

    Science.gov (United States)

    Shukla, Surabhi; Einstein, A; Shukla, Abhilasha; Mishra, Deepika

    2015-01-01

    Background: Liquid-based cytology (LBC), recommended in the mass screening of potentially malignant cervical and oral lesions, suffers from high cost owing to the use of expensive automated devices and materials. Considering the need for cost-effective LBC techniques, we evaluated the efficacy of an inexpensive manual LBC (MLBC) technique against conventional cytological technique in terms of specimen adequacy and smear quality of oral smears. Materials and Methods: Cytological samples were collected from 21 patients using a cytobrush device. After preparation of a conventional smear, the brush containing the remaining sample was immersed in the preservative vial. The preserved material was processed by an MLBC technique and subsequently, direct smears were made from the prepared cell button. Both conventional and MLBC smears were stained by routine Papanicolaou technique and evaluated by an independent observer for the thickness of the smear, cellular distribution, resolution/clarity of cells, cellular staining characteristics and the presence of unsatisfactory background/artifacts. Each parameter was graded as satisfactory; or satisfactory, but limited; or unsatisfactory. Chi-square test was used to compare the values obtained (significance set at P ≤ 0.05). Results: MLBC technique produced a significant number of satisfactory smears with regard to cell distribution, clarity/resolution, staining characteristics and background/artifacts compared to conventional methods. Conclusions: MLBC is a cost-effective cytological technique that may produce oral smears with excellent cytomorphology and longer storage life. PMID:26980958

  20. 3-V Solid-State Flexible Supercapacitors with Ionic-Liquid-Based Polymer Gel Electrolyte for AC Line Filtering.

    Science.gov (United States)

    Kang, Yu Jin; Yoo, Yongju; Kim, Woong

    2016-06-08

    State-of-the-art solid-state flexible supercapacitors with sufficiently fast response speed for AC line filtering application suffer from limited energy density. One of the main causes of the low energy density is the low cell voltage (1 V), which is limited by aqueous-solution-based gel electrolytes. In this work, we demonstrate for the first time a 3-V flexible supercapacitor for AC line filtering based on an ionic-liquid-based polymer gel electrolyte and carbon nanotube electrode material. The flexible supercapacitor exhibits an areal energy density that is more than 20 times higher than that of the previously demonstrated 1-V flexible supercapacitor (0.66 vs 0.03 μWh/cm(2)) while maintaining excellent capacitive behavior at 120 Hz. The supercapacitor shows a maximum areal power density of 1.5 W/cm(2) and a time constant of 1 ms. The improvement of the cell voltage while maintaining the fast-response capability greatly improves the potential of supercapacitors for high-frequency applications in wearable and/or portable electronics.

  1. Ionic liquid-based microwave-assisted extraction of essential oil and biphenyl cyclooctene lignans from Schisandra chinensis Baill fruits.

    Science.gov (United States)

    Ma, Chun-hui; Liu, Ting-ting; Yang, Lei; Zu, Yuan-gang; Chen, Xiaoqiang; Zhang, Lin; Zhang, Ying; Zhao, Chunjian

    2011-12-02

    Ionic liquid-based microwave-assisted extraction (ILMAE) has been successfully applied in extracting essential oil and four kinds of biphenyl cyclooctene lignans from Schisandra chinensis Baill. 0.25 M 1-lauryl-3-methylimidazolium bromide ionic liquid is selected as solvent. The optimum parameters of dealing with 25.0 g sample are 385 W irradiation power, 40 min microwave extraction time and 1:12 solid-liquid ratio. The yields of essential oil and lignans are 12.12±0.37 ml/kg and 250.2±38.2 mg/kg under the optimum conditions. The composition of the essential oil extracted by hydro-distillation, steam-distillation and ILMAE is analyzed by GC-MS. With ILMAE method, the energy consumption time has not only been shortened to 40 min (hydro-distillation 3.0 h for extracting essential oil and reflux extraction 4.0 h for extracting lignans, respectively), but also the extraction efficiency has been improved (extraction of lignans and distillation of essential oil at the same time) and reduces the environmental pollution. S. chinensis materials treated by different methods are observed by scanning electronic microscopy. Micrographs provide more evidence to prove that ILMAE is a better and faster method. The experimental results also indicate that ILMAE is a simple and efficient technique for sample preparation.

  2. A comparative analysis of conventional cytopreparatory and liquid based cytological techniques (Sure Path) in evaluation of serous effusion fluids.

    Science.gov (United States)

    Dadhich, Hrishikesh; Toi, Pampa Ch; Siddaraju, Neelaiah; Sevvanthi, Kalidas

    2016-11-01

    Clinically, detection of malignant cells in serous body fluids is critical, as their presence implies the upstaging of the disease. Cytology of body cavity fluids serves as an important tool when other diagnostic tests cannot be performed. In most laboratories, currently, the effusion fluid samples are analysed chiefly by the conventional cytopreparatory (CCP) technique. Although, there are several studies comparing the liquid-based cytology (LBC), with CCP technique in the field of cervicovaginal cytology; the literature on such comparison with respect to serous body fluid examination is sparse. One hundred samples of serous body fluids were processed by both CCP and LBC techniques. Slides prepared by these techniques were studied using six parameters. A comparative analysis of the advantages and disadvantages of the techniques in detection of malignant cells was carried out with appropriate statistical tests. The samples comprised 52 pleural, 44 peritoneal and four pericardial fluids. No statistically significant difference was noted with respect to cellularity (P values = 0.22), cell distribution (P values = 0.39) and diagnosis of malignancy (P values = 0.20). As for the remaining parameters, LBC provided statistically significant clearer smear background (P values cytologic interpretation point of view. Diagn. Cytopathol. 2016;44:874-879. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  3. Aqueous ionic liquid based ultrasonic assisted extraction of four acetophenones from the Chinese medicinal plant Cynanchum bungei Decne.

    Science.gov (United States)

    Sun, Yinshi; Liu, Zhengbo; Wang, Jianhua; Yang, Saifei; Li, Baiqing; Xu, Ning

    2013-01-01

    In this study, an aqueous ionic liquid based ultrasonic assisted extraction (ILUAE) method for the extraction of the four acetophenones, namely 4-hydroxyacetophenone (1), 2,5-dihydroxyacetophenone (2), baishouwubenzophenone (3) and 2,4-dihydroxyacetophenone (4) from the Chinese medicinal plant Cynanchum bungei was developed. Three kinds of aqueous l-alkyl-3-methylimidazolium ionic liquids with different anion and alkyl chain were investigated. The results indicated that ionic liquids (ILs) showed remarkable effects on the extraction efficiency of acetophenones. In addition, the ILUAE, including several ultrasonic parameters, such as the ILs concentration, solvent to solid ratio, power, particle size, temperature, and extraction time have been optimized. Under these optimal conditions (e.g., with 0.6M [C(4)MIM]BF(4), solvent to solid ratio of 35:1, power of 175 W, particle size of 60-80 mesh, temperature of 25 ° C and time of 50 min), this approach gained the highest extraction yields of four acetophenones 286.15, 21.65, 632.58 and 205.38 μg/g, respectively. The proposed approach has been evaluated by comparison with the conventional heat-reflux extraction (HRE) and regular UAE. The results indicated that ILUAE is an alternative method for extracting acetophenones from C. bungei.

  4. Rapid screening of oxytetracycline residue in catfish muscle by dispersive liquid-liquid microextraction and europium-sensitized luminescence

    Science.gov (United States)

    Oxytetracycline (OTC) residue in catfish muscle was screened by dispersive liquid-liquid microextraction (DLLME) and europium-sensitized luminescence (ESL). After extraction in EDTA, HCl, and acetonitrile, cleanup was carried out by DLLME, and ESL was measured at microgram = 385 nm and wavelength = ...

  5. Sensitive Determination of Terazosin in Pharmaceutical Formulations and Biological Samples by Ionic-Liquid Microextraction Prior to Spectrofluorimetry

    Directory of Open Access Journals (Sweden)

    Mohsen Zeeb

    2012-01-01

    Full Text Available An efficient and environmentally friendly sample preparation method based on the application of hydrophobic 1-Hexylpyridinium hexafluorophosphate [Hpy][PF6] ionic liquid (IL as a microextraction solvent was proposed to preconcentrate terazosin. The performance of the microextraction method was improved by introducing a common ion of pyridinium IL into the sample solution. Due to the presence of the common ion, the solubility of IL significantly decreased. As a result, the phase separation successfully occurred even at high ionic strength, and the volume of the settled IL-phase was not influenced by variations in the ionic strength (up to 30% w/v. After preconcentration step, the enriched phase was introduced to the spectrofluorimeter for the determination of terazosin. The obtained results revealed that this system did not suffer from the limitations of that in conventional ionic-liquid microextraction. Under optimum experimental conditions, the proposed method provided a limit of detection (LOD of 0.027 μg L−1 and a relative standard deviation (R.S.D. of 2.4%. The present method was successfully applied to terazosin determination in actual pharmaceutical formulations and biological samples. Considering the large variety of ionic liquids, the proposed microextraction method earns many merits, and will present a wide application in the future.

  6. Sensitive determination of terazosin in pharmaceutical formulations and biological samples by ionic-liquid microextraction prior to spectrofluorimetry.

    Science.gov (United States)

    Zeeb, Mohsen; Sadeghi, Mahdi

    2012-01-01

    An efficient and environmentally friendly sample preparation method based on the application of hydrophobic 1-Hexylpyridinium hexafluorophosphate [Hpy][PF(6)] ionic liquid (IL) as a microextraction solvent was proposed to preconcentrate terazosin. The performance of the microextraction method was improved by introducing a common ion of pyridinium IL into the sample solution. Due to the presence of the common ion, the solubility of IL significantly decreased. As a result, the phase separation successfully occurred even at high ionic strength, and the volume of the settled IL-phase was not influenced by variations in the ionic strength (up to 30% w/v). After preconcentration step, the enriched phase was introduced to the spectrofluorimeter for the determination of terazosin. The obtained results revealed that this system did not suffer from the limitations of that in conventional ionic-liquid microextraction. Under optimum experimental conditions, the proposed method provided a limit of detection (LOD) of 0.027 μg L(-1) and a relative standard deviation (R.S.D.) of 2.4%. The present method was successfully applied to terazosin determination in actual pharmaceutical formulations and biological samples. Considering the large variety of ionic liquids, the proposed microextraction method earns many merits, and will present a wide application in the future.

  7. Direct solid-phase microextraction combined with gas and liquid chromatography for the determination of lidocaine in human urine

    NARCIS (Netherlands)

    Koster, E.H M; Hofman, N.S K; de Jong, G.J.

    1998-01-01

    Solid-phase microextraction (SPME) has been combined with gas chromatography (GC) and liquid chromatography (LC) for the determination of lidocaine in human urine. A polydimethylsiloxane (PDMS) coated fibre was directly immersed into buffered urine. Extraction conditions such as time, pH, ionic stre

  8. Enhanced kinetics of solid-phase microextraction and biodegradation of polycyclic aromatic hydrocarbons in the presence of dissolved organic matter

    NARCIS (Netherlands)

    Haftka, J.J.H.; Parsons, J.R.; Govers, H.A.J.; Ortega-Calvo, J.J.

    2008-01-01

    The uptake kinetics of fluorene, phenanthrene, fluoranthene, pyrene, and benzo[e]pyrene by solid-phase microextraction fibers was studied in the presence of dissolved organic matter (DOM) obtained from sediment pore water and resulted in increased fiber absorption and desorption rate coefficients. C

  9. Identification of Toxic 2,4-Decadienal in Oxidized, Low-Density Lipoprotein by Solid-Phase Microextraction.

    Science.gov (United States)

    Spiteller; Spiteller

    2000-02-01

    The oxidation of low-density lipoprotein (LDL) in vitro was studied by a combination of solid-phase microextraction and GC/MS. 2-trans,4-cis-2,4-Decadienal, which is strongly toxic in vitro, was detected as the early oxidation product. This compound is degraded further to hexanal and (by cyclization of 4-hydroxy-2-nonenal) to 2-pentylfuran.

  10. Sensing dissolved sediment porewater concentrations of persistent and bioaccumulative poolutants using disposable solid-phase microextraction fibers

    NARCIS (Netherlands)

    Mayer, P.; Vaes, W.H.J.; Wijnker, F.; Legierse, K.C.H.M.; Kraaij, R.H.; Tolls, J.; Hermens, J.L.M.

    2000-01-01

    Polymer coated glass fibers were applied as disposable samplers to measure dissolved concentrations of persistent and bioaccumulative pollutants (PBPs) in sediment porewater. The method is called matrix solid-phase microextraction (matrix-SPME), because it utilizes the entire sediment matrix as a re

  11. Application of head-space solid-phase microextraction for the analysis of volatile metabolites emitted by Penicillium species

    DEFF Research Database (Denmark)

    Nilsson, Torben; Larsen, Thomas Ostenfeld; Montanarella, Luca

    1996-01-01

    Head-space solid-phase microextraction (HS-SPME) has been used to collect volatile organic compounds (VOCs) emitted from fungi of the genus Penicillium. Gas chromatography combined with mass spectrometry (GC-MS) was employed for the analysis of the profiles of volatile metabolites characteristic ...

  12. Analyzing freely dissolved concentrations of cationic surfactant utilizing ion-exchange capability of polyacrylate coated solid-phase microextraction fibers

    NARCIS (Netherlands)

    Chen, Y.; Droge, S.T.J.; Hermens, J.L.M.

    2012-01-01

    A 7-μm polyacrylate (PA) coated fiber was successfully employed to determine freely dissolved concentrations of cationic surfactants by solid-phase microextraction (SPME) and utilizing the capability of the PA-coating to sorb organic cations via ion-exchange at carboxylic groups. Measured fiber-wate

  13. Microextraction Techniques Used in the Procedures for Determining Organomercury and Organotin Compounds in Environmental Samples

    Directory of Open Access Journals (Sweden)

    Małgorzata Rutkowska

    2014-06-01

    Full Text Available Due to human activities, the concentrations of organometallic compounds in all parts of the environment have increased in recent decades. The toxicity and some biochemical properties of mercury and tin present in the environment depend on the concentration and chemical form of these two elements. The ever-increasing demand for determining compounds at very low concentration levels in samples with complex matrices requires the elimination of interfering substances, the reduction of the final extract volume, and analyte enrichment in order to employ a detection technique, which is characterised by high sensitivity at low limits of quantification. On the other hand, in accordance with current trends, the analytical procedures should aim at the miniaturisation and simplification of the sample preparation step. In the near future, more importance will be given to the fulfilment of the requirements of Green Chemistry and Green Analytical Chemistry in order to reduce the intensity of anthropogenic activities related to analytical laboratories. In this case, one can consider the use of solvent-free/solvent-less techniques for sample preparation and microextraction techniques, because the use of the latter leads to lowering the quantity of reagents used (including solvents due to the reduction of the scale of analysis. This paper presents an overview of microextraction techniques (SPME and LPME used in the procedures for determining different chemical forms of mercury and tin.

  14. Matrix compatible solid phase microextraction coating, a greener approach to sample preparation in vegetable matrices.

    Science.gov (United States)

    Naccarato, Attilio; Pawliszyn, Janusz

    2016-09-01

    This work proposes the novel PDMS/DVB/PDMS fiber as a greener strategy for analysis by direct immersion solid phase microextraction (SPME) in vegetables. SPME is an established sample preparation approach that has not yet been adequately explored for food analysis in direct immersion mode due to the limitations of the available commercial coatings. The robustness and endurance of this new coating were investigated by direct immersion extractions in raw blended vegetables without any further sample preparation steps. The PDMS/DVB/PDMS coating exhibited superior features related to the capability of the external PDMS layer to protect the commercial coating, and showed improvements in terms of extraction capability and in the cleanability of the coating surface. In addition to having contributed to the recognition of the superior features of this new fiber concept before commercialization, the outcomes of this work serve to confirm advancements in the matrix compatibility of the PDMS-modified fiber, and open new prospects for the development of greener high-throughput analytical methods in food analysis using solid phase microextraction in the near future.

  15. Extraction of pesticides in water samples using vortex-assisted liquid-liquid microextraction.

    Science.gov (United States)

    Jia, Chunhong; Zhu, Xiaodan; Wang, Jihua; Zhao, Ercheng; He, Min; Chen, Li; Yu, Pingzhong

    2010-09-10

    A simple solvent microextraction method termed vortex-assisted liquid-liquid microextraction (VALLME) coupled with gas chromatography micro electron-capture detector (GC-microECD) has been developed and used for the pesticide residue analysis in water samples. In the VALLME method, aliquots of 30 microL toluene used as extraction solvent were directly injected into a 25 mL volumetric flask containing the water sample. The extraction solvent was dispersed into the water phase under vigorously shaking with the vortex. The parameters affecting the extraction efficiency of the proposed VALLME such as extraction solvent, vortex time, volumes of extraction solvent and salt addition were investigated. Under the optimum condition, enrichment factors (EFs) in a range of 835-1115 and limits of detection below 0.010 microg L(-1) were obtained for the determination of target pesticides in water. The calculated calibration curves provide high levels of linearity yielding correlation coefficients (r(2)) greater than 0.9958 with the concentration level ranged from 0.05 to 2.5 microg L(-1). Finally, the proposed method has been successfully applied to the determination of pesticides from real water samples and acceptable recoveries over the range of 72-106.3% were obtained.

  16. Determination of amphetamines in human urine by headspace solid-phase microextraction and gas chromatography.

    Science.gov (United States)

    Raikos, Nikolaos; Christopoulou, Klio; Theodoridis, Georgios; Tsoukali, Heleni; Psaroulis, Dimitrios

    2003-06-05

    Solid-phase microextraction (SPME) is under investigation for its usefulness in the determination of a widening variety of volatile and semivolatile analytes in biological fluids and materials. Semivolatiles are increasingly under study as analytical targets, and difficulties with small partition coefficients and long equilibration times have been identified. Amphetamines were selected as semivolatiles exhibiting these limitations and methods to optimize their determination were investigated. A 100- micro m polydimethylsiloxane (PDMS)-coated SPME fiber was used for the extraction of the amphetamines from human urine. Amphetamine determination was made using gas chromatography (GC) with flame-ionization detection (FID). Temperature, time and salt saturation were optimized to obtain consistent extraction. A simple procedure for the analysis of amphetamine (AMP) and methamphetamine (MA) in urine was developed and another for 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxy-N-methamphetamine (MDMA) and 3,4-methylenedioxy-N-ethylamphetamine (MDEA) using headspace solid-phase microextraction (HS-SPME) and GC-FID. Higher recoveries were obtained for amphetamine (19.5-47%) and methamphetamine (20-38.1%) than MDA (5.1-6.6%), MDMA (7-9.6%) and MDEA (5.4-9.6%).

  17. Selective fiber used for headspace solid-phase microextraction of abused drugs in human urine

    Directory of Open Access Journals (Sweden)

    Sunanta Wangkarn

    2007-09-01

    Full Text Available A sensitive and selective fiber for simultaneous analysis of three drugs of abuse (amphetamine, methamphetamine and ephedrine in urine samples was explored using headspace solid phase microextraction and gas chromatography with flame ionization detection. Several parameters affecting extraction such as extraction time, extraction temperature, pH of solution and salt concentrations were investigated. Among five commercially available fibers, divinylbenzene/carboxen/ polydimethylsiloxane is the most sensitive and selective fiber at pH 10.0, extraction temperature at 80 C for 20 min and desorption temperature at 220 C for 2 min. Under the optimal conditions, the proposed solid phase microextraction method provided good linearity in the ranges 0.1-10 µg/ml for amphetamine and methamphetamine and 0.5-20 µg/ml for ephedrine. The detection limits for amphetamine, methamphetamine and ephedrine were 9, 3 and 30 ng/ml, respectively. The recoveries of three drugs in urine samples were exceeding 85%.

  18. Determination of four heterocyclic insecticides by ionic liquid dispersive liquid-liquid microextraction in water samples.

    Science.gov (United States)

    Liu, Yu; Zhao, Ercheng; Zhu, Wentao; Gao, Haixiang; Zhou, Zhiqiang

    2009-02-01

    A novel microextraction method termed ionic liquid dispersive liquid-liquid microextraction (IL-DLLME) combining high-performance liquid chromatography with diode array detection (HPLC-DAD) was developed for the determination of insecticides in water samples. Four heterocyclic insecticides (fipronil, chlorfenapyr, buprofezin, and hexythiazox) were selected as the model compounds for validating this new method. This technique combines extraction and concentration of the analytes into one step, and the ionic liquid was used instead of a volatile organic solvent as the extraction solvent. Several important parameters influencing the IL-DLLME extraction efficiency such as the volume of extraction solvent, the type and volume of disperser solvent, extraction time, centrifugation time, salt effect as well as acid addition were investigated. Under the optimized conditions, good enrichment factors (209-276) and accepted recoveries (79-110%) were obtained for the extraction of the target analytes in water samples. The calibration curves were linear with correlation coefficient ranged from 0.9947 to 0.9973 in the concentration level of 2-100 microg/L, and the relative standard deviations (RSDs, n=5) were 4.5-10.7%. The limits of detection for the four insecticides were 0.53-1.28 microg/L at a signal-to-noise ratio (S/N) of 3.

  19. Carbon nanocones/disks as new coating for solid-phase microextraction.

    Science.gov (United States)

    Jiménez-Soto, Juan Manuel; Cárdenas, Soledad; Valcárcel, Miguel

    2010-05-14

    In this article, the potential of carbon nanocones/disks as coating for solid-phase microextraction has been evaluated for the first time. The nanostructures were immobilized on a stainless steel needle by means of an organic binder. The fiber coating obtained was ca. 50 microm of thickness and 35 mm in length. The evaluation of the sorbent capacity was carried out through the determination of toluene, ethylbenzene, xylene isomers and styrene in water samples following the headspace sampling modality (15 min, 30 degrees C). The fiber was then transferred to a 10 mL vial which was sealed and heated at 110 degrees C for 15 min in the headspace module of the instrument to achieve the thermal desorption of the analytes. Then 2.5 mL of the headspace generated were injected in the gas chromatograph-mass spectrometer for analytes separation and quantitation. The detection and quantitation limits obtained for 10 mL of sample were 0.15 and 0.5 ng mL(-1) (0.6 and 2 ng mL(-1) for toluene). The optimized procedure was applied to the determination of the selected volatile compounds in waters collected from different locations. The recovery values obtained (average recovery ca. 92%) demonstrated the usefulness of the carbon nanocones/disks as sorbent material in solid-phase microextraction.

  20. Solid-phase microextraction-gas chromatographic determination of volatile monoaromatic hydrocarbons in soil.

    Science.gov (United States)

    Zygmunt, B; Namiesnik, J

    2001-08-01

    Benzene, toluene, ethylbenzene, three isomers of xylene, and cumene have been isolated and enriched from soil samples by a combination of water extraction at room and elevated temperature and headspace-solid-phase microextraction before their gas chromatographic-mass spectrometric (GC-MS) determination. The conditions used for all stages of sample preparation and chromatographic analysis were optimized. Analytes sampled on a polydimethylsiloxane-coated solid-phase microextraction fiber were thermally desorbed in the split/splitless injector of a gas chromatograph (GC) coupled with a mass spectrometer (MS). The desorption temperature was optimized. The GC separation was performed in a capillary column. Detection limits were found to be of the order of ca. 1 ng g(-1). Relative recoveries of the analytes from soils were found to be highly dependent on soil organic-matter content and on compound identity; they ranged from ca 92 to 96% for sandy soil (extraction at room temperature) and from ca 27 to 55% for peaty soil (extraction at elevated temperature). A few real-world soil samples were analyzed; the individual monoaromatic hydrocarbon content ranged from below detection limits to 6.4 ng g(-1) for benzene and 8.1 for the total of p- + m-xylene.

  1. Recent developments and future trends in solid phase microextraction techniques towards green analytical chemistry.

    Science.gov (United States)

    Spietelun, Agata; Marcinkowski, Łukasz; de la Guardia, Miguel; Namieśnik, Jacek

    2013-12-20

    Solid phase microextraction find increasing applications in the sample preparation step before chromatographic determination of analytes in samples with a complex composition. These techniques allow for integrating several operations, such as sample collection, extraction, analyte enrichment above the detection limit of a given measuring instrument and the isolation of analytes from sample matrix. In this work the information about novel methodological and instrumental solutions in relation to different variants of solid phase extraction techniques, solid-phase microextraction (SPME), stir bar sorptive extraction (SBSE) and magnetic solid phase extraction (MSPE) is presented, including practical applications of these techniques and a critical discussion about their advantages and disadvantages. The proposed solutions fulfill the requirements resulting from the concept of sustainable development, and specifically from the implementation of green chemistry principles in analytical laboratories. Therefore, particular attention was paid to the description of possible uses of novel, selective stationary phases in extraction techniques, inter alia, polymeric ionic liquids, carbon nanotubes, and silica- and carbon-based sorbents. The methodological solutions, together with properly matched sampling devices for collecting analytes from samples with varying matrix composition, enable us to reduce the number of errors during the sample preparation prior to chromatographic analysis as well as to limit the negative impact of this analytical step on the natural environment and the health of laboratory employees.

  2. Determination of Atrazine, Acetochlor, Clomazone, Pendimethalin and Oxyfluorfen in Soil by a Solid Phase Microextraction Method

    Directory of Open Access Journals (Sweden)

    Rada Đurović

    2008-01-01

    Full Text Available A solid phase microextraction (SPME method for simultaneous determination of atrazine, acetochlor, clomazone, pendimethalin and oxyfluorfen in soil samples was developed. The method is based on a combination of conventional liquid-solid procedure and a following SPME determination of the selected pesticides. Initially, various microextraction conditions, such as the fibre type, desorption temperature and time, extraction time and NaCl content, were investigated and optimized. Then, extraction efficiencies of severalsolvents (water, hexane, acetonitrile, acetone and methanol and the optimum number of extraction steps within the sample preparation step were optimized. According to the results obtained in these two sets of experiments, two successive extractions with methanol as the extraction solvent were the optimal sample preparation procedure, while the following conditions were found to be most efficient for SPME measurements: 100 μm PDMS fibre, desorption for 7 min at 2700C, 30 min extraction time and 5% NaCl content (w/v. Detection and quantification were done by gas chromatography-mass spectrometry(GC/MS. Relative standard deviation (RSD values for multiple analysis of soil samples fortified at 30 μg/kg of each pesticide were below 19%. Limits of detection (LOD for all the compounds studied were less than 2 μg/kg.

  3. Evaluation of polyethersulfone performance for the microextraction of polar chlorinated herbicides from environmental water samples.

    Science.gov (United States)

    Prieto, Ailette; Rodil, Rosario; Quintana, José Benito; Cela, Rafael; Möder, Monika; Rodríguez, Isaac

    2014-05-01

    In this work, the suitability of bulk polyethersulfone (PES) for sorptive microextraction of eight polar, chlorinated phenoxy acids and dicamba from environmental water samples is assessed and the analytical features of the optimized method are compared to those reported for other microextraction techniques. Under optimized conditions, extractions were performed with samples (18 mL) adjusted at pH 2 and containing a 30% (w/v) of sodium chloride, using a tubular PES sorbent (1 cm length × 0.7 mm o.d., sorbent volume 8 µL). Equilibrium conditions were achieved after 3h of direct sampling, with absolute extraction efficiencies ranging from 39 to 66%, depending on the compound. Analytes were recovered soaking the polymer with 0.1 mL of ethyl acetate, derivatized and determined by gas chromatography-mass spectrometry (GC-MS). Achieved quantification limits (LOQs) varied between 0.005 and 0.073 ng mL(-1). After normalization with the internal surrogate (IS), the efficiency of the extraction was only moderately affected by the particular characteristics of different water samples (surface and sewage water); thus, pseudo-external calibration, using spiked ultrapure water solutions, can be used as quantification technique. The reduced cost of the PES polymer allowed considering it as a disposable sorbent, avoiding variations in the performance of the extraction due to cross-contamination problems and/or surface modification with usage. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Tandem dispersive liquid-liquid microextraction as an efficient method for determination of basic drugs in complicated matrices.

    Science.gov (United States)

    Bazregar, Mohammad; Rajabi, Maryam; Yamini, Yadollah; Saffarzadeh, Zahra; Asghari, Alireza

    2016-01-15

    A simple and efficient approach is introduced for the improvement of the clean-up and applicability of the dispersive liquid-liquid microextraction (DLLME) method in complicated matrices. For this purpose, two dispersive microextraction methods were combined, and the tandem dispersive liquid-liquid microextraction (TDLLME) method was provided. At first, using the ultrasound-assisted emulsification microextraction (USAEME) method, the tricyclic anti-depressant (TCA) drugs nortriptyline, imipramine, and amitriptyline, as the model compounds, contained in an aqueous sample solution (8.0 mL), were extracted into an organic solvent (35 μL). Then by utilizing the air-agitated liquid-liquid microextraction (AALLME) method, these analytes were simply back-extracted into 50 μL of an aqueous acceptor phase. By performing this convenient extraction method, a high sample clean-up was obtained; the overall extraction time was 7 min. The back-extraction step could be performed in less than 2 min, and very simple tools were required for this purpose. The response surface methodology (RSM) was used for the optimization of the experimental parameters so that the volumes 95 and 50 μL were obtained for the organic solvent and the acceptor phase, respectively, and the pH values of 11.25 and 1.75 were obtained for the donor and acceptor phases, respectively, as the optimal extraction conditions. Under the optimized conditions, TDLLME-HPLC-UV provided a good linearity in the range of 2.5-5000 ng mL(-1), low limits of detection (0.7-1.0 ng mL(-1)), good extraction repeatabilities (relative standard deviations below 6.2%, n=5), and enrichment factors (EFs) of 50-101. Finally, the developed method was successfully used for the determination of the mentioned drugs in the wastewater and human plasma samples.

  5. Microextraction Techniques Coupled to Liquid Chromatography with Mass Spectrometry for the Determination of Organic Micropollutants in Environmental Water Samples

    Directory of Open Access Journals (Sweden)

    Mª Esther Torres Padrón

    2014-07-01

    Full Text Available Until recently, sample preparation was carried out using traditional techniques, such as liquid–liquid extraction (LLE, that use large volumes of organic solvents. Solid-phase extraction (SPE uses much less solvent than LLE, although the volume can still be significant. These preparation methods are expensive, time-consuming and environmentally unfriendly. Recently, a great effort has been made to develop new analytical methodologies able to perform direct analyses using miniaturised equipment, thereby achieving high enrichment factors, minimising solvent consumption and reducing waste. These microextraction techniques improve the performance during sample preparation, particularly in complex water environmental samples, such as wastewaters, surface and ground waters, tap waters, sea and river waters. Liquid chromatography coupled to tandem mass spectrometry (LC/MS/MS and time-of-flight mass spectrometric (TOF/MS techniques can be used when analysing a broad range of organic micropollutants. Before separating and detecting these compounds in environmental samples, the target analytes must be extracted and pre-concentrated to make them detectable. In this work, we review the most recent applications of microextraction preparation techniques in different water environmental matrices to determine organic micropollutants: solid-phase microextraction SPME, in-tube solid-phase microextraction (IT-SPME, stir bar sorptive extraction (SBSE and liquid-phase microextraction (LPME. Several groups of compounds are considered organic micropollutants because these are being released continuously into the environment. Many of these compounds are considered emerging contaminants. These analytes are generally compounds that are not covered by the existing regulations and are now detected more frequently in different environmental compartments. Pharmaceuticals, surfactants, personal care products and other chemicals are considered micropollutants. These

  6. Simultaneous determination of cork taint and Brett character responsible compounds in wine using ultrasound-assisted emulsification microextraction with solidification of floating organic drop.

    Science.gov (United States)

    Pizarro, C; Sáenz-González, C; Pérez-del-Notario, N; González-Sáiz, J M

    2012-08-03

    In this study, ultrasound-assisted emulsification microextraction combined with solidification of floating organic drop method (USAEME-SFOD) has been proposed as a novel approach for the sensitive determination of haloanisoles and volatile phenols in wines. For this purpose, the influence of the different parameters affecting the procedure (type and volume of extraction solvent, temperature, time and ionic strength) was evaluated in order to optimise the efficiency of the process. Subsequently, the linearity, detection and quantification limits, precision, recoveries and applicability to real samples were studied, obtaining excellent method performance results. Moreover, USAEME-SFOD was compared with other liquid-liquid microextraction methods such as dispersive liquid-liquid microextraction (DLLME) and ultrasound-assisted emulsification microextraction (USAEME). This comparison study proved the suitability of USAEME-SFOD as an alternative to previously reported methods for the simultaneous determination of cork taint and Brett character responsible compounds in wines.

  7. Dispersive liquid–liquid microextraction combined with laser-induced breakdown spectrometry and inductively coupled plasma optical emission spectrometry to elemental analysis

    OpenAIRE

    Gaubeur, Ivanise; Aguirre Pastor, Miguel Ángel; Kovachev, Nikolay; Hidalgo Núñez, Montserrat; Canals Hernández, Antonio

    2015-01-01

    In this paper, two analytical methodologies based on the combination of dispersive liquid–liquid microextraction with inductively coupled plasma optical emission spectrometry and laser-induced breakdown spectrometry, respectively, were evaluated for simultaneous preconcentration and detection of Cd, Co, Ni, Pb and Zn. The microextraction procedure was based on the injection of appropriate quantities of 1-undecanol and methanol into the sample solution containing the complexes formed between m...

  8. Preconcentration of Copper Using 1,5-Diphenyl Carbazide as the Complexing Agent via Dispersive Liquid-Liquid Microextraction and Determination by Flame Atomic Absorption Spectrometry

    OpenAIRE

    Reyhaneh Rahnama; Elaheh Shafiei; Mohammad Reza Jamali

    2013-01-01

    We report a simple and sensitive microextraction system for the preconcentration and determination of Cu (II) by flame atomic absorption spectrometry (FAAS). Dispersive liquid-liquid microextraction is a modified solvent extraction method and its acceptor-to-donor phase ratio is greatly reduced compared with other methods. In the proposed approach, 1,5-diphenyl carbazide (DPC) was used as a copper ion selective complexing agent. Several variables such as the extraction and dispersive solvent ...

  9. The Role of Liquid Based Cytology and Ancillary Techniques in the Peritoneal Washing Analysis: Our Institutional Experience

    Science.gov (United States)

    Rossi, Esther; Bizzarro, Tommaso; Martini, Maurizio; Longatto-Filho, Adhemar; Schmitt, Fernando; Fagotti, Anna; Scambia, Giovanni; Zannoni, Gian Franco

    2017-01-01

    Background The cytological analysis of peritoneal effusions serves as a diagnostic and prognostic aid for either primary or metastatic diseases. Among the different cytological preparations, liquid based cytology (LBC) represents a feasible and reliable method ensuring also the application of ancillary techniques (i.e immunocytochemistry-ICC and molecular testing). Methods We recorded 10348 LBC peritoneal effusions between January 2000 and December 2014. They were classified as non-diagnostic (ND), negative for malignancy-NM, atypical-suspicious for malignancy-SM and positive for malignancy-PM. Results The cytological diagnosis included 218 ND, 9.035 NM, 213 SM and 882 PM. A total of 8048 (7228 NM, 115SM, 705 PM) cases with histological follow-up were included. Our NM included 21 malignant and 7207 benign histological diagnoses. Our 820 SMs+PMs were diagnosed as 107 unknown malignancies (30SM and 77PM), 691 metastatic lesions (81SM and 610PM), 9 lymphomas (2SM and 7PM), 9 mesotheliomas (1SM and 8SM), 4 sarcomas (1SM and 3PM). Primary gynecological cancers contributed with 64% of the cases. We documented 97.4% sensitivity, 99.9% specificity, 98% diagnostic accuracy, 99.7% negative predictive value (NPV) and 99.7% positive predictive value (PPV). Furthermore, the morphological diagnoses were supported by either 173 conclusive ICC results or 50 molecular analyses. Specifically the molecular testing was performed for the EGFR and KRAS mutational analysis based on the previous or contemporary diagnoses of Non Small Cell Lung Cancer (NSCLC) and colon carcinomas. We identified 10 EGFR in NSCCL and 7 KRAS mutations on LBC stored material. Conclusions Peritoneal cytology is an adjunctive tool in the surgical management of tumors mostly gynecological cancers. LBC maximizes the application of ancillary techniques such as ICC and molecular analysis with feasible diagnostic and predictive yields also in controversial cases. PMID:28099523

  10. Value of centrifugated liquid-based cytology by Papanicolaou and May-Grünwald in oral epithelial cells

    Directory of Open Access Journals (Sweden)

    Hussain Gadelkarim Ahmed

    2009-07-01

    Full Text Available For many years, liquid-based cytology (LBC has been developed for cervical cancer screening and not oral cancer, as it requires automated devices. The aim of this study was to compare the utility of centrifugated CLBC preparation with that of direct preparation in oral lesions, by Papanicolaou (Pap and May Grünwald-Giemsa's (MGG methods. A total of 100 consecutive cases of oral lesions were investigated. We compared the results obtained by the CLBC performed by cytocentrifugation with those obtained by direct smear applying Pap and MGG methods. The comparison between CLBC and direct smears was based on the thickening or adequacy of the smear, distribution of cells and staining quality. All smears in CLBC and direct preparation were found adequate. For thickness of the smear, 40% and 42% were excellent, 33% and 30% were good, and 27% and 28% were acceptable by LBC and direct preparation, respectively. For the distribution of cells and scantiness of background elements, 92 (92% smears of the CLBC have revealed clear, well distributed smears, compared to 70 (70% of those in direct preparation. For the staining quality with the Pap method, 39% and 69% were excellent staining quality, 25% and 20% were good, and 36% and 11% were acceptable for CLBC and direct preparation, respectively. In MGG method, 9% and 22% were excellent staining quality, 23% and 36% were good and 68% and 43% were acceptable for CLBC and direct preparation respectively. CLBC performed by cytocentrifugation is inexpensive, and reduces inadequate smears and background staining.

  11. Manual liquid based cytology in primary screening for cervical cancer--a cost effective preposition for scarce resource settings.

    Science.gov (United States)

    Nandini, N M; Nandish, S M; Pallavi, P; Akshatha, S K; Chandrashekhar, A P; Anjali, S; Dhar, Murali

    2012-01-01

    Conventional pap smear (CPS) examination has been the mainstay for early detection of cervical cancer. However, its widespread use has not been possible due to the inherent limitations, like presence of obscuring blood and inflammation, reducing its sensitivity considerably. Automated methods in use in developed countries may not be affordable in the developing countries due to paucity of resources. On the other hand, manual liquid based cytology (MLBC) is a technique that is cost effective and improves detection of precursor lesions and specimen adequacy. Therefore the aim of the study was to compare the utility of MLBC with that of CPS in cervical cancer screening. A prospective study of 100 cases through MLBC and CPS was conducted from October 2009 to July 2010, in a Medical College in India, by two independent pathologists and correlated with histopathology (22 cases). Morphological features as seen through MLBC and CPS were compared. Subsequently, all the cases were grouped based on cytological diagnosis according to two methods into 10 groups and a subjective comparison was made. In order to compare the validity of MLBC with CPS in case of major diagnoses, sensitivity and specificity of the two methods were estimated considering histological examination as the gold standard. Increased detection rate with MLBC was 150%. The concordance rate by LBC/histopathology v/s CPS/histopathology was also improved (86% vs 77%) The percentage agreement by the two methods was 68%. MLBC was more sensitive in diagnosis of LSIL and more specific in the diagnosis of inflammation. Thus, MLBC was found to be better than CPS in diagnosis of precursor lesions. It provided better morphology with increased detection of abnormalities and preservation of specimen for cell block and ancillary studies like immunocytochemistry and HPV detection. Therefore, it can be used as alternative strategy for cervical cancer prevention in limited resource settings.

  12. Diagnostic Value of Liquid-Based Cytology in Urothelial Carcinoma Diagnosis: A Systematic Review and Meta-Analysis.

    Directory of Open Access Journals (Sweden)

    You Luo

    Full Text Available To evaluate the value of liquid-based cytology (LBC in the diagnosis of urothelial carcinoma.Diagnostic studies were searched for the diagnostic value of LBC in urothelial carcinoma in PubMed, Embase, Cochrane Library, Web of Science, CBM and CNKI. The latest retrieval date was September 2014. The data were extracted and the quality of the included studies was independently assessed by 2 reviewers. Stata 13 software was used to perform the statistical analysis. The research was conducted in compliance with the PRISMA statement.Nineteen studies, which included 8293 patients, were evaluated. The results of the meta-analysis showed that the pooled sensitivity and specificity of LBC were 0.58 (0.51-0.65 and 0.96 (0.93-0.98, respectively. The diagnostic odds ratio (DOR was 31 (18-56 and the area under the curve (AUC of summary receiver operating characteristic (SROC was 0.83 (0.80-0.86. The post-test probability was 80% when a positive diagnosis was made. Compared with high grade urothelial carcinoma (HGUC, the sensitivity of detecting low-grade urothelial carcinoma (LGUC was significantly lower, risk ratio of sensitivity was 0.54 (0.43-0.66, P<0.001. However, no significant sensitivity improvement was observed with LBC when compared with traditional cytospin cytology, risk ratio was 1.03 (0.94-1.14, P = 0.524.Despite LBC having a pooled 58% positive rate for urothelial carcinoma diagnosis in our meta-analysis, no significant improvement in sensitivity was observed based on the studies evaluated. Further research is needed to validate these findings.

  13. Unsatisfactory rate in liquid-based cervical samples as compared to conventional smears: A study from tertiary care hospital

    Directory of Open Access Journals (Sweden)

    Nalini Gupta

    2016-01-01

    Full Text Available Background: Developed countries adopted liquid-based cytology (LBC cervical cytology, partly because of its lower proportions of unsatisfactory (U/S/inadequate samples. This study was carried out to evaluate effect on the rate of U/S samples after introduction of LBC in our laboratory. Materials and Methods: An audit of U/S cervical samples was performed, which included split samples (n = 1000, only conventional Pap smear (CPS smears (n = 1000, and only LBC samples (n = 1000. The smears were reviewed by two observers independently, and adequacy for the samples was assessed as per The Bethesda System 2001. The reasons for U/S rate in split samples were categorized into various cytologic and/or technical reasons. Results: U/S rate was far less in only LBC samples (1.2% as compared to only CPS (10.5% cases. Cases in the satisfactory but limited category were also less in only LBC (0.4% as compared to only CPS (3.2% samples. The main reasons for U/S smears in split samples were low cell count (37.2% in CPS; 58.8% in LBC. The second main reason was low cellularity with excess blood and only excess blood in CPS samples. Conclusion: There was a significant reduction of U/S rate in LBC samples as compared to CPS samples, and the difference was statistically significant. The main cause of U/S samples in LBC was low cellularity indicating a technical fault in sample collection. The main cause of U/S rate in CPS was low cellularity followed by low cellularity with excess blood. Adequate training of sample takers and cytologists for the precise cell count to determine adequacy in smears can be of great help in reducing U/S rate.

  14. Quantitative assessment of DNA methylation for the detection of cervical and endometrial adenocarcinomas in liquid-based cytology specimens.

    Science.gov (United States)

    Kim, Ga-Eon; Kweon, Sun-Seog; Lee, Ji Shin; Lee, Jae Hyuk; Nam, Jong Hee; Choi, Chan

    2012-08-01

    To investigate the aberrant promoter hypermethylation as a screening tool for cervical adenocarcinomas (CAs) and endometrial adenocarcinomas (EAs) in cervical scrapings. A quantitative multiplex methylation-specific polymerase chain reaction approach was used to examine promoter methylation of 5 genes (APC, HIN-1, RAR-beta, RASSF1A and Twist) in biopsy-confirmed CA (n = 31) and EA (n = 27) residual, liquid-based cytology samples. The data of negative for intraepithelial lesions or malignancy and low-grade squamous intraepithelial lesions were used as controls. Methylation levels of APC, RAR-beta, RASSF1A and Twist were significantly higher in CA than in control cervical samples. For EA, only the methylation levels of RASSF1A differed significantly from those of control. Receiver-operating characteristic analysis demonstrated that APC, RAR-beta and RASSF1A had the ability to distinguish CA/EA, CA and EA from control samples. In CA/EA and CA samples, the best 3-gene combination was RASSF1A/RAR-beta/APC. This 3-gene panel had a sensitivity of 87.0% for CA/EA and of 80.6% for CA and a specificity of 79.3% for both CA/EA and CA. In EA samples, RASSF1A showed the best performance in distinguishing EA from control. The estimated sensitivity of RASSF1A for detecting EA was 63.0%, and its specificity was 96.3%. This feasibility study demonstrates that quantitative detection of aberrant DNA methylation in cervical scrapings may be a promising new diagnostic tool for the detection of CA and EA.

  15. Pooled Analysis of Performance of Liquid Based Cytology in Population-Based Cervical Cancer Screening Studies in China

    Science.gov (United States)

    Pan, Qin-Jing; Hu, Shang-ying; Zhang, Xun; Ci, Pu-wa; Zhang, Wen-hua; Guo, Hui-qin; Cao, Jian; Zhao, Fang-hui; Lytwyn, Alice; Qiao, You-lin

    2013-01-01

    Background Liquid based cytology (LBC) has been widely used for cervical cancer screening. Despite numerous studies and systematic reviews, few large studies have focused on biopsy-confirmed cervical lesions and controversy remains about its diagnostic accuracy. The aim of our study was to assess LBC for detecting biopsy-confirmed cervical intraepithelial neoplasia (CIN) and cancer. Methods We performed a pooled analysis of LBC using data from 13 population-based, cross-sectional, cervical-cancer screening studies performed in China from 1999 to 2008. Participants (n = 26782) received LBC and HPV testing. Screen-positive women were referred for colposcopy and biopsy. We analyzed the accuracy of LBC for detecting biopsy-confirmed CIN2 or worse lesion (CIN2+) as well as CIN3 or worse lesion (CIN3+). Results Of 25830 women included in the analysis, CIN2+ was found in 107/2612(4.1%) with ASC, 142/923 (15.4%) with LSIL, 512/784 (65.3%) with HSIL, 29/30 (96.7%) with SCC, 4/27(14.8%) with AGC, and 0.4% (85/21454) with normal cytology results. No invasive cancers had ASC, AGC or cytological normal slides. The overall sensitivity, specificity, PPV, NPV and accuracy of LBC for detecting CIN2+ were 81.0%, 95.4%, 38.3%, 99.3 % and 94.9% respectively. Although HC2 was more sensitive than LBC, the specificity, PPV and overall accuracy of LBC were higher than those of HC2, at 85.2%, 18.6% and 85.5%, respectively. Conclusions The results indicate that performance of LBC can effectively predict a risk of existing CIN2+ and may be a good screening tool for cervical cancer prevention in a developing country. PMID:23907807

  16. Diagnostic Value of Liquid-Based Cytology in Urothelial Carcinoma Diagnosis: A Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Luo, You; She, Dong-Li; Xiong, Hu; Yang, Li; Fu, Sheng-Jun

    2015-01-01

    To evaluate the value of liquid-based cytology (LBC) in the diagnosis of urothelial carcinoma. Diagnostic studies were searched for the diagnostic value of LBC in urothelial carcinoma in PubMed, Embase, Cochrane Library, Web of Science, CBM and CNKI. The latest retrieval date was September 2014. The data were extracted and the quality of the included studies was independently assessed by 2 reviewers. Stata 13 software was used to perform the statistical analysis. The research was conducted in compliance with the PRISMA statement. Nineteen studies, which included 8293 patients, were evaluated. The results of the meta-analysis showed that the pooled sensitivity and specificity of LBC were 0.58 (0.51-0.65) and 0.96 (0.93-0.98), respectively. The diagnostic odds ratio (DOR) was 31 (18-56) and the area under the curve (AUC) of summary receiver operating characteristic (SROC) was 0.83 (0.80-0.86). The post-test probability was 80% when a positive diagnosis was made. Compared with high grade urothelial carcinoma (HGUC), the sensitivity of detecting low-grade urothelial carcinoma (LGUC) was significantly lower, risk ratio of sensitivity was 0.54 (0.43-0.66), Pcytology, risk ratio was 1.03 (0.94-1.14), P = 0.524. Despite LBC having a pooled 58% positive rate for urothelial carcinoma diagnosis in our meta-analysis, no significant improvement in sensitivity was observed based on the studies evaluated. Further research is needed to validate these findings.

  17. Unsatisfactory rate in liquid-based cervical samples as compared to conventional smears: A study from tertiary care hospital

    Science.gov (United States)

    Gupta, Nalini; Bhar, Vikrant S.; Rajwanshi, Arvind; Suri, Vanita

    2016-01-01

    Background: Developed countries adopted liquid-based cytology (LBC) cervical cytology, partly because of its lower proportions of unsatisfactory (U/S)/inadequate samples. This study was carried out to evaluate effect on the rate of U/S samples after introduction of LBC in our laboratory. Materials and Methods: An audit of U/S cervical samples was performed, which included split samples (n = 1000), only conventional Pap smear (CPS) smears (n = 1000), and only LBC samples (n = 1000). The smears were reviewed by two observers independently, and adequacy for the samples was assessed as per The Bethesda System 2001. The reasons for U/S rate in split samples were categorized into various cytologic and/or technical reasons. Results: U/S rate was far less in only LBC samples (1.2%) as compared to only CPS (10.5%) cases. Cases in the satisfactory but limited category were also less in only LBC (0.4%) as compared to only CPS (3.2%) samples. The main reasons for U/S smears in split samples were low cell count (37.2% in CPS; 58.8% in LBC). The second main reason was low cellularity with excess blood and only excess blood in CPS samples. Conclusion: There was a significant reduction of U/S rate in LBC samples as compared to CPS samples, and the difference was statistically significant. The main cause of U/S samples in LBC was low cellularity indicating a technical fault in sample collection. The main cause of U/S rate in CPS was low cellularity followed by low cellularity with excess blood. Adequate training of sample takers and cytologists for the precise cell count to determine adequacy in smears can be of great help in reducing U/S rate. PMID:27382408

  18. Liquid-based and conventional cytology for bronchial washings/bronchoalveolar lavages in the diagnosis of malignancy - An institutional experience.

    Science.gov (United States)

    Thakur, Abha; Bakshi, Pooja; Kaur, Gagandeep; Verma, Kusum

    2017-01-01

    Liquid-based cytology (LBC) has been developed as an alternative for conventional cytology (CC) in cervical smears. It is now increasingly being used all over the world for cervical cancer screening. However, its role and diagnostic accuracy in bronchial wash (BW)/bronchoalveolar lavage (BAL) specimens remains undetermined. To assess and compare the diagnostic performance and accuracy of LBC with CC for detecting malignancy in bronchial specimens. This was a retrospective analytical hospital-based study. Bronchial specimens (BW/BAL) received over a period of 4.5 years were reviewed. The samples were processed by CC from June 2010 to September 2012 (2.25 years) and by LBC from October 2012 to December 2014 (2.25 years). Data were retrieved from the records of cytology laboratory and compared among both the groups. Detection rate for histologically or cytologically verified samples was calculated. A total of 559 cases verified by histological and cytological follow-up were evaluated. These included 247 CC cases and 312 LBC cases. The positive diagnostic rate for malignancy in CC was 28.6% whereas that for LBC was 32.9%. The negative diagnostic rates were 66.5% and 66.3% for CC and LBC, respectively. However, unsatisfactory rates had shown a good reduction from 4.4% in CC to 0.6% after LBC introduction. The smears showed more homogeneous distribution of cells with elimination of obscuring factors such as blood, inflammation, and mucus. The diagnostic accuracy of LBC was slightly better than CC. The unsatisfactory rates showed reduction in LBC preparation. Thus, LBC is a viable alternative to CC and has the advantages of standardization of preparation with decrease in unsatisfactory rates.

  19. Liquid-based versus conventional cytology in solid pediatric neoplasm: Comparison of their diagnostic and morphological spectra.

    Science.gov (United States)

    Agarwal, Preeti; Yadav, Sunita; Kumar, Archana; Goel, Madhu M

    2016-01-01

    Conventional cytology (CC) is a well-established and effective methodology for the evaluation of pediatric tumors. Liquid-based cytology (LBC) is a better technique of smear preparation and is at present the standard protocol in cervical cytology samples. In the present study, we analyzed both smear preparatory techniques in fine-needle aspiration (FNA) samples from solid pediatric neoplasms in terms of adequacy and efficacy with objectives to study the changes in background and morphology of tumor cells in LBC smears. This was a prospective observational study conducted in a tertiary care teaching hospital, which included 52 pediatric patients with clinical diagnosis of malignancy and an assessable lump. Both conventional aspiration cytology and LBC smears were prepared as per standard protocols (SurePath BD™) from FNA samples of cases and examined. On comparing the diagnostic efficacy of cytology smears prepared by both techniques, LBC alone was diagnostic in 80.8% of the cases and conventional smear (CS) alone was diagnostic in 71.2% of the cases (agreement was 83.7%, P = 0.3). Cellular morphology was better preserved in LBC and interpretation was easier. There was a lower inadequacy rate in LBC and none of the samples was inadequate due to poor morphology in LBC smears (P = 0.0003). LBC showed an overall 40% improvement in inadequate cases by CS. LBC has been recommended as a complement to CC in nongynecological samples. Improved morphology and lower inadequacy rate make LBC a finer technique compared to CS in pediatric tumors as well.

  20. Transformation zone sampling rate used as a performance indicator for cervical liquid-based cytology sample-takers.

    Science.gov (United States)

    Faraker, C A; Greenfield, J

    2013-08-01

    To investigate the sampling performance of individual cervical cytology practitioners using the transformation zone sampling rate (TZSR) as a performance indicator and to assess the impact of dedicated on site training for those identified with a low TZSR. The TZSR was calculated for all practitioners submitting ThinPrep(®) cervical cytology specimens to the Conquest laboratory between January 2010 and November 2011. After excluding those with less than 30 qualifying samples the 10th percentile of the TZSR was calculated. Practitioners with a TZSR below the 10th percentile were visited by a specialist cervical cytology screening facilitator after which the TZSR of these practitioners was closely monitored. After exclusions there were 175 practitioners who had collected 24 358 qualifying liquid-based cytology (LBC) samples. The average TZSR was 70% (range 12-96%). The 10th percentile was 44%; 18 scored below the 10th percentile. Failure to apply sufficient pressure when sampling was identified as the most common reason for a low TZSR. In some cases there was suspicion that the cervix was not always adequately visualized. Continuous monitoring after assessment identified improvement in the TZSRs of 13/18 practitioners. Identification of practitioners with low TZSRs compared with their peers allows these individuals to be selected for personalized observation and training by a specialist in cervical cytology which can lead to an improvement in TZSR. As previous studies show a significant correlation between the TZSR and the detection rate of cytological abnormality it is useful to investigate low TZSRs. © 2013 John Wiley & Sons Ltd.

  1. The role of liquid-based cytology and ancillary techniques in pleural and pericardic effusions: an institutional experience.

    Science.gov (United States)

    Rossi, Esther Diana; Bizzarro, Tommaso; Schmitt, Fernando; Longatto-Filho, Adhemar

    2015-04-01

    Fine-needle aspiration cytology (FNAC) of serous membrane effusions may fulfil a challenging role in the diagnostic analysis of both primary and metastatic disease. From this perspective, liquid-based cytology (LBC) represents a feasible and reliable method for empowering the performance of ancillary techniques (ie, immunocytochemistry and molecular testing) with high diagnostic accuracy. In total, 3171 LBC pleural and pericardic effusions were appraised between January 2000 and December 2013. They were classified as negative for malignancy (NM), suspicious for malignancy (SM), or positive for malignancy (PM). The cytologic diagnoses included 2721 NM effusions (2505 pleural and 216 pericardic), 104 SM effusions (93 pleural and 11 pericardic), and 346 PM effusions (321 pleural and 25 pericardic). The malignant pleural series included 76 unknown malignancies (36 SM and 40 PM effusions), 174 metastatic lesions (85 SM and 89 PM effusions), 14 lymphomas (3 SM and 11 PM effusions), 16 mesotheliomas (5 SM and 11 SM effusions), and 3 myelomas (all SM effusions). The malignant pericardic category included 20 unknown malignancies (5 SM and 15 PM effusions), 15 metastatic lesions (1 SM and 14 PM effusions), and 1 lymphoma (1 PM effusion). There were 411 conclusive immunocytochemical analyses and 47 molecular analyses, and the authors documented 88% sensitivity, 100% specificity, 98% diagnostic accuracy, 98% negative predictive value, and 100% positive predictive value for FNAC. FNAC represents a primary diagnostic tool for effusions and a reliable approach with which to determine the correct follow-up. Furthermore, LBC is useful for ancillary techniques, such as immunocytochemistry and molecular analysis, with feasible diagnostic and predictive utility. © 2015 American Cancer Society.

  2. Performance of the Cellslide® automated liquid-based cytology system amongst HIV-positive women

    Directory of Open Access Journals (Sweden)

    Pamela Michelow

    2016-02-01

    Full Text Available Background: Many women undergoing cervical screening as part of a national South African screening programme may be positive for HIV. The performance of liquid-based cytology (LBC on samples from HIV-positive women needs to be determined.Objectives: The performance of the Cellslide® automated LBC system was evaluated as a possible alternative to conventional cytology in a national cervical cancer screening programme.Methods: Split samples from 348 HIV-positive women attending an HIV treatment clinic in Johannesburg, South Africa were examined by conventional cytology and monolayer LBC methods. All samples were stained, examined and reported in the same manner. Cytotechnologists were blinded to the conventional smear diagnosis if the LBC smear was screened and vice versa.Results: The same percentage of inadequate smears (1.4% was obtained by conventional cytology and LBC. Atypical squamous cells of undetermined significance were observed in 5.2% of conventional smears and 4.0% of LBC smears. Low-grade squamous intraepithelial lesions were found in 35.6% of conventional smears and 32.7% of LBC smears. Only one conventional smear was categorised as atypical squamous cells – cannot exclude a high-grade lesion, whereas five such cases were identified on LBC. High-grade squamous intraepithelial lesions were seen in 21.6% of conventional smears and 23.3% LBC smears. No invasive carcinoma was identified.Conclusion: The performance of the Cellslide® LBC system was similar to that of conventional cytology in this population of high-risk HIV-positive women, indicating that it may be introduced successfully as part of a cervical cancer screening programme.

  3. A new sonication-assisted ionic liquid-based route to microcrystals of lanthanide fluorides and their photoluminescent properties

    Energy Technology Data Exchange (ETDEWEB)

    Li, Yinyan; Xu, Shiqing, E-mail: sxucjlu@hotmail.com

    2014-07-15

    Highlights: • Microcrystals of lanthanide fluorides were prepared by sonication-assisted IL-based route. • It is a fast, simple, green and mild method to get lanthanide fluoride microcrystals. • The microcrystals are uniform, monodisperse, well-shaped and phase-pure. • IL served as reaction medium, fluoride source as well as template. • Sonication helped to accelerate reaction and get monodisperse uniform microcrystals. - Abstract: We introduce an ionic liquid-based method for the synthesis of uniform lanthanide fluoride microcrystals with the assistance of a sonication-accelerated reaction system. It is a fast, simple and mild process to get uniform monodisperse spherical lanthanide fluoride microcrystals in large scale. Homogeneous precipitation in a biphasic system of ethanol solution of lanthanide nitrates and ionic liquid 1-butyl-3-methylimidazolium hexafluorophosphate [C{sub 4}mim][PF{sub 6}] led to the uniform LnF{sub 3} microcrystals. The method was applied to the preparation of pure LnF{sub 3} (Ln = La, Ce, Pr, Nd) and Eu{sup 3+}-doped LaF{sub 3}, Tb{sup 3+}-doped CeF{sub 3}. SEM images indicated highly uniform cotton-like spherical microcrystals were obtained. HRTEM image indicated that the microcrystals were aggregated by nanocrystals of 6–10 nm due to agglomeration effect of the ionic liquid. The uniformity and dispersility of LaF{sub 3} decreased with the increasing of the molar ratio of [C{sub 4}mim][PF{sub 6}] to La(NO{sub 3}){sub 3}·6H{sub 2}O. Diameter of the microcrystal decreased from La to Nd. Photoluminescence properties of Eu{sup 3+}-doped LaF{sub 3} and Tb{sup 3+}-doped CeF{sub 3} were also studied.

  4. Detection of nuclear and membrane antigens by liquid-based cytology following long-term storage of d1 cells, karpas cells, and peripheral blood mononuclear cells.

    Science.gov (United States)

    Zappacosta, Roberta; Aiello, Francesca B; D'Antuono, Tommaso; Procopio, Antonio D; Durum, Scott K; Conti, Pio; Rosini, Sandra

    2011-01-01

    Immunofluorescence is the most frequently utilized technique to analyze protein expression. Fixed immunofluorescent cell suspensions, however, can only be stored for a week. We investigated whether liquid-based cytology could be used to detect antigens in cultured cells after a long storage period. Murine and human cells were fixed in PreservCyt solution, stored for various periods, and then used to perform an automated immunocytochemical analysis. Phosphorylation of the nuclear transcription factor Stat-5 induced by IL-7 was detected up to 4 months after IL-7 stimulation. Simultaneous nuclear positivity for the proliferation index MIB-1 and membrane positivity for the CD30 antigen were evident three months after fixation. Liquid-based cytology thus ensures long-lasting nuclear and membrane antigen immunoreactivity and permits the storage of cells from laborious experiments at room temperature for future analyses.

  5. Effect of glacial acetic acid treatment of liquid-based cytology collections on performance of Cervista HPV HR for detection of high-risk human papillomavirus.

    Science.gov (United States)

    Munson, Erik; Du Chateau, Brian K; Nelson, Bridget E; Griep, Judith; Czarnecka, Jolanta; Amrhein, Robert D; Schroeder, Elizabeth R

    2012-06-01

    Inadequate cervical cytological analysis can be facilitated by glacial acetic acid (GAA) treatment of primary liquid-based collections to remove mucus, erythrocytes, inflammatory cells, and cellular debris. In the context of a commercial human papillomavirus (HPV) hybridization assay performed on 465 tandem specimens with and without GAA treatment, we show that GAA treatment significantly reduces genomic DNA content (P cytological workflow, laboratories should consider providing a specimen aliquot for HPV DNA detection prior to GAA treatment.

  6. The impact of the introduction of liquid based cytology on the variation in the proportion of inadequate samples between GP practices

    Directory of Open Access Journals (Sweden)

    Jones Suzanne P

    2007-08-01

    Full Text Available Abstract Background Historically there has been a wide variation in the proportion of inadequate smears between general practices. Cervical screening in the UK is undergoing a fundamental change by moving from conventional to liquid based cytology (LBC. The main driver for this change has been a predicted reduction in the proportions of inadequate samples. This study investigates the effect of LBC on the variation in the proportion of inadequate samples between general practices using Shewhart's theory of variation and control charts. Methods Routinely collected cervical cytology data was obtained for all general practices in two localities in South Staffordshire for periods before and after the introduction of liquid based cytology. Control charts of the proportion of inadequate smears were plotted for the practices stratified by laboratory. A standardised measure of variation for all of the practices in each laboratory and each time period was also calculated. Results Following the introduction of liquid based cytology the overall proportion of inadequate samples in the two localities fell from 11.8 to 1.3% (p Conclusion A reduction in the proportion of inadequate samples has been realised in these localities. The reduction in the overall proportion of inadequate samples has also been accompanied by a reduction in variation between GP practices.

  7. Liquid-based cytological test of samples obtained by catheter aspiration is applicable for the bronchoscopic confirmation of pulmonary malignant tumors

    Science.gov (United States)

    Li, Dai-Rong; Wan, Tao; Su, Yi; Ding, Min; Wu, Jin-Xing; Zhao, Yong

    2014-01-01

    The aim of the present study is to confirm the value of electronic bronchoscopy-aided catheter aspiration technique with liquid-based cytological test in the diagnosis of bronchogenic carcinoma. A total of 815 patients of lung cancer were evaluated by bronchoscopy between February 2011 and June 2012. Catheter aspiration technique and forceps biopsy during bronchoscopy were employed to obtain adequate tissue specimens. Liquid-based cytological test and conventional smears for catheter aspiration were used for cytological detection of the tumors. For all cytological specimens, slide preparations with LCT and CS were reviewed by two senior pathologists, who were blinded to patient medical history. Complications related to electronic bronchoscopy, such as bleeding, were clinically judged as light, moderate or severe by the needs for clinical interventions. The diagnostic yield of catheter aspiration in endobronchial visible lesions (tumor, infiltrative and necrotic lesions) was 94.6% (success rates concerning malignancy), which was slightly higher than that of the forceps biopsy (91.4%, P biopsy (51.4%, P biopsy with the cytological analysis of the catheter aspiration increased the diagnostic sensitivity in both lesion types (P biopsy. Liquid-based cytological test is routinely applicable for the diagnosis of lung cancer using samples collected through electronic bronchoscopy. PMID:24966963

  8. HPV testing in combination with liquid-based cytology in primary cervical screening (ARTISTIC): a randomised controlled trial.

    Science.gov (United States)

    Kitchener, Henry C; Almonte, Maribel; Thomson, Claire; Wheeler, Paula; Sargent, Alexandra; Stoykova, Boyka; Gilham, Clare; Baysson, Helene; Roberts, Christopher; Dowie, Robin; Desai, Mina; Mather, Jean; Bailey, Andrew; Turner, Andrew; Moss, Sue; Peto, Julian

    2009-07-01

    Testing for human papillomavirus (HPV) DNA is reportedly more sensitive than cytology for the detection of high-grade cervical intraepithelial neoplasia (CIN). The effectiveness of HPV testing in primary cervical screening was assessed in the ARTISTIC trial, which was done over two screening rounds approximately 3 years apart (2001-03 and 2004-07) by comparing liquid-based cytology (LBC) combined with HPV testing against LBC alone. Women aged 20-64 years who were undergoing routine screening as part of the English National Health Service Cervical Screening Programme in Greater Manchester were randomly assigned (between July, 2001, and September, 2003) in a ratio of 3:1 to either combined LBC and HPV testing in which the results were revealed and acted on, or to combined LBC and HPV testing where the HPV result was concealed from the patient and investigator. The primary outcome was the detection rate of cervical intraepithelial neoplasia grade 3 or worse (CIN3+) in the second screening round, analysed by intention to treat. This trial is registered with the International Standard Randomised Controlled Trial Number ISRCTN25417821. There were 24 510 eligible women at entry (18 386 in the revealed group, 6124 in the concealed group). In the first round of screening 233 women (1.27%) in the revealed group had CIN3+, compared with 80 (1.31%) women in the concealed group (odds ratio [OR] 0.97, 95% CI 0.75-1.25; p>0.2). There was an unexpectedly large drop in the proportion of women with CIN3+ between the first and second rounds of screening in both groups, at 0.25% (29 of 11 676) in the revealed group and 0.47% (18 of 3866 women) in the concealed group (OR 0.53, 95% CI 0.30-0.96; p=0.042). For both rounds combined, the proportion of women with CIN3+ were 1.51% (revealed) and 1.77% (concealed) (OR 0.85, 95% CI 0.67-1.08; p>0.2). LBC combined with HPV testing resulted in a significantly lower detection rate of CIN3+ in the second round of screening compared with LBC

  9. Pooled analysis of the performance of liquid-based cytology in population-based cervical cancer screening studies in China.

    Science.gov (United States)

    Pan, Qin-Jing; Hu, Shang-ying; Zhang, Xun; Ci, Pu-wa; Zhang, Wen-hua; Guo, Hui-qin; Cao, Jian; Zhao, Fang-hui; Lytwyn, Alice; Qiao, You-lin

    2013-09-01

    Liquid-based cytology (LBC) has been widely used for cervical cancer screening. Despite numerous studies and systematic reviews, to the authors' knowledge few large studies to date have focused on biopsy-confirmed cervical lesions and controversy remains concerning its diagnostic accuracy. The objective of the current study was to assess LBC for detecting biopsy-confirmed cervical intraepithelial neoplasia (CIN) and cancer. A pooled analysis of LBC using data from 13 population-based, cross-sectional, cervical cancer screening studies performed in China from 1999 to 2008 was performed. Participants (n = 26,782) received LBC and human papillomavirus testing. Women found to be positive on screening were referred for colposcopy and biopsy. The accuracy of LBC for detecting biopsy-confirmed CIN of type 2 or worse (CIN2+) as well as CIN type 3 or worse (CIN3+) lesions was analyzed. Of 25,830 women included in the analysis, CIN2+ was found in 107 of 2612 with atypical squamous cells (4.1%), 142 of 923 with low-grade squamous intraepithelial neoplasia (15.4%), 512 of 784 with high-grade squamous intraepithelial neoplasia (65.3%), 29 of 30 with squamous cell carcinoma (96.7%), 4 of 27 with atypical glandular cells (14.8%), and 85 of 21,454 with normal cytology results (0.4%). No invasive cancers were found to have atypical squamous cells, atypical glandular cells, or cytologically normal slides. The overall sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of LBC for detecting CIN2+ were 81.0%, 95.4%, 38.3%, 99.3 %, and 94.9%, respectively. Although Hybrid Capture 2 was more sensitive than LBC, the specificity, positive predictive value, and overall accuracy of LBC were higher than those of Hybrid Capture2 at 85.2%, 18.6%, and 85.5%, respectively. The results of the current study indicate that the performance of LBC can effectively predict the risk of existing CIN2+ and may be a good screening tool for cervical cancer prevention

  10. Rapid screening of water soluble arsenic species in edible oils using dispersive liquid-liquid microextraction.

    Science.gov (United States)

    López-García, Ignacio; Briceño, Marisol; Vicente-Martínez, Yesica; Hernández-Córdoba, Manuel

    2015-01-15

    A methodology for the non-chromatographic screening of the main arsenic species present in edible oils is discussed. Reverse dispersive liquid-liquid microextraction was used to extract water soluble arsenic compounds (inorganic arsenic, methylarsonate, dimethylarsinate and arsenobetaine) from the edible oils into a slightly acidic aqueous medium. The total arsenic content was measured in the extracts by electrothermal atomic absorption spectrometry using palladium as the chemical modifier. By repeating the measurement using cerium instead of palladium, the sum of inorganic arsenic and methylarsonate was obtained. The detection limit was 0.03 ng As per gram of oil. Data for the total and water-soluble arsenic levels of 29 samples of different origin are presented. Inorganic arsenic was not found in any of the samples marketed as edible oils.

  11. A novel hybrid metal-organic framework-polymeric monolith for solid-phase microextraction.

    Science.gov (United States)

    Lin, Chen-Lan; Lirio, Stephen; Chen, Ya-Ting; Lin, Chia-Her; Huang, Hsi-Ya

    2014-03-17

    This study describes the fabrication of a novel hybrid metal-organic framework- organic polymer (MOF-polymer) for use as a stationary phase in fritless solid-phase microextraction (SPME) for validating analytical methods. The MOF-polymer was prepared by using ethylene dimethacrylate (EDMA), butyl methacrylate (BMA), and an imidazolium-based ionic liquid as porogenic solvent followed by microwave-assisted polymerization with the addition of 25 % MOF. This novel hybrid MOF-polymer was used to extract penicillin (penicillin G, penicillin V, oxacillin, cloxacillin, nafcillin, dicloxacillin) under different conditions. Quantitative analysis of the extracted penicillin samples using the MOF-organic polymer for SPME was conducted by using capillary electrochromatography (CEC) coupled with UV analysis. The penicillin recovery was 63-96.2 % with high reproducibility, sensitivity, and reusability. The extraction time with the proposed fabricated SPME was only 34 min.

  12. Analysis of volatiles of malt whisky by solid-phase microextraction and stir bar sorptive extraction.

    Science.gov (United States)

    Demyttenaere, Jan C R; Martínez, Jorge I Sánchez; Verhé, Roland; Sandra, Pat; De Kimpe, Norbert

    2003-01-24

    Blended Scotch whisky was analysed by solid-phase microextraction (SPME) and stir bar sorptive extraction (SBSE) to study the composition of the volatiles. For SPME analysis, three different fibres were compared, poly(dimethylsiloxane) (PDMS) (100 microm). poly(acrylate) (PA) (85 microm) and divinylbenzene-Carboxen on poly(dimethylsiloxane) (DVB-CAR-(PDMS) (50/30 microm). It was found that the PDMS and DVB-CAR-PDMS fibres showed a higher enrichment capacity than PA as well as a better reproducibility. The influence of sampling time, temperature and salt addition on the enrichment of volatiles as well as the difference between liquid and headspace SPME were studied. An optimum SPME method was developed. Finally a more recent sample preparation technique, namely SBSE was evaluated to extract whisky volatiles.

  13. Determination of trace lead in biological and water samples with dispersive liquid-liquid microextraction preconcentration.

    Science.gov (United States)

    Liang, Pei; Sang, Hongbo

    2008-09-01

    A new method for the determination of trace lead was developed by dispersive liquid-liquid microextraction preconcentration and graphite furnace atomic absorption spectrometry. In the proposed approach, 1-phenyl-3-methyl-4-benzoyl-5-pyrazolone (PMBP) was used as a chelating agent, and carbon tetrachloride and ethanol were selected as extraction and dispersive solvents. Some factors influencing the extraction efficiency of lead and its subsequent determination, including extraction and dispersive solvent type and volume, pH of sample solution, concentration of the chelating agent, and extraction time, were studied and optimized. Under the optimum conditions, the enrichment factor of this method for lead was reached at 78. The detection limit for lead was 39 ng L(-1) (3 sigma), and the relative standard deviation (RSD) was 3.2% (n=7, c=10 ng mL(-1)). The method was successfully applied to the determination of trace amounts of lead in human urine and water samples.

  14. Application of solid-phase microextraction combined with derivatization to the enantiomeric determination of amphetamines.

    Science.gov (United States)

    Cháfer-Pericás, C; Campíns-Falcó, P; Herráez-Hernández, R

    2006-03-18

    The utility of combining chiral derivatization and solid-phase microextraction (SPME) for the enantiomeric analysis of primary amphetamines by liquid chromatography has been investigated. Different derivatization/extraction strategies have been evaluated and compared using the chiral reagent o-phthaldialdehyde (OPA)-N-acetyl-l-cysteine (NAC) and fibres with a Carbowax-templated resin coating. Amphetamine, norephedrine and 3,4-methylenedioxyamphetamine (MDA) were used as model compounds. On the basis of the results obtained, a new method is presented based on the derivatization of the analytes in solution followed by SPME of the OPA-NAC derivatives formed. The proposed conditions have been applied to determine the compounds of interest at low ppm levels (urine samples. Data on the linearity, reproducibility, sensitivity and selectivity are given. The utility of the described procedure for the quantification of amphetamine, norephedrine and MDA enantiomers in different kind of samples is also discussed.

  15. Pre-concentration of uranium from water samples by dispersive liquid-liquid micro-extraction

    Energy Technology Data Exchange (ETDEWEB)

    Khajeh, Mostafa; Nemch, Tabandeh Karimi [Zabol Univ. (Iran, Islamic Republic of). Dept. of Chemistry

    2014-07-01

    In this study, a simple and rapid dispersive liquid-liquid microextraction (DLLME) was developed for the determination of uranium in water samples prior to high performance liquid chromatography with diode array detection. 1-(2-pyridylazo)-2-naphthol (PAN) was used as complexing agent. The effect of various parameters on the extraction step including type and volume of extraction and dispersive solvents, pH of solution, concentration of PAN, extraction time, sample volume and ionic strength were studied and optimized. Under the optimum conditions, the limit of detection (LOD) and preconcentration factor were 0.3 μg L{sup -1} and 194, respectively. Furthermore, the relative standard deviation of the ten replicate was <2.6%. The developed procedure was then applied to the extraction and determination of uranium in the water samples.

  16. Sol-Gel-Coated Calix[4]arene Fiber for Solid-Phase Microextraction

    Institute of Scientific and Technical Information of China (English)

    LiXiu-juan; XiaoRui-min; LiHai-bing; ZengZhao-rui

    2003-01-01

    5, 11, 17, 23-tetra-tert-butyl-25, 27-diethoxy-26, 28-dihydroxycalix [4] arene/hydroxy-terminated silicone oil coated fiber was first prepared and applied for solid-phase microextraction with sol-gel technology. The properties of the new coating were investigated by analysis of benzene derivatives, polycyclic aromatic hydrocarbons and aromatic amines.The fiber is characterized by good sensitivity and selectivity to these aromatics. The fiber has stable performance at a high temperature of 380℃ and after a long solvent immersing,thus its lifetime is very long. It shows good fiber-to-fiber and batch-to-batch reproducibility. Furthermore, broad linear ranges and low detection limits are also its characteristics.

  17. Headspace Solid-Phase Microextraction Analysis of Volatile Components in Phalaenopsis Nobby’s Pacific Sunset

    Directory of Open Access Journals (Sweden)

    Chih-Hsin Yeh

    2014-09-01

    Full Text Available Phalaenopsis is the most important economic crop in the Orchidaceae family. There are currently numerous beautiful and colorful Phalaenopsis flowers, but only a few species of Phalaenopsis have an aroma. This study reports the analysis volatile components present in P. Nobby’s Pacific Sunset by solid-phase microextraction (SPME coupled with gas chromatography (GC and gas chromatography/mass spectrometry (GC-MS. The results show that the optimal extraction conditions were obtained by using a DVB/CAR/PDMS fiber. A total of 31 compounds were identified, with the major compounds being geraniol, linalool and α-farnesene. P. Nobby’s Pacific Sunset had the highest odor concentration from 09:00 to 13:00 on the eighth day of storage. It was also found that in P. Nobby’s Pacific Sunset orchids the dorsal sepals and petals had the highest odor concentrations, whereas the column had the lowest.

  18. Sol-Gel-Coated Calix[4]arene Fiber for Solid-Phase Microextraction

    Institute of Scientific and Technical Information of China (English)

    Li Xiu-juan; Xiao Rui-min; Li Hai-bing; Zeng Zhao-rui

    2003-01-01

    5,11,17,23-tetra-tert-butyl-25, 27-diethoxy-26, 28-dihydroxycalix [4] arene /hydroxy-terminated silicone oil coated fiber was first prepared and applied for solid-phase microextraction with sol-gel technology. The properties of the new coating were investigated by analysis of benzene derivatives, polycyclic aromatic hydrocarbons and aromatic amines. The fiber is characterized by good sensitivity and selectivity to these aromatics. The fiber has stable performance at a high temperature of 380℃ and after a long solvent immersing, thus its lifetime is very long. It shows good fiber-to-fiber and batch-to-batch reproducibility. Furthermore, broad linear ranges and low detection limits are also its characteristics.

  19. Rapid determination of atrazine in environmental water samples by a novel liquid phase microextraction

    Institute of Scientific and Technical Information of China (English)

    Qing Xiang Zhou; Guo Hong Xie; Long Pang

    2008-01-01

    A novel method was described for the rapid determination of atrazine using dispersive liquid phase microextraction incombination with high performance liquid chromatography (HPLC). Possible impact parameters such as sample pH, extraction anddisperser solvents, salting-out effect, and extraction time were investigated. The experimental results indicated that proposedmethod possessed an excellent analytical performance. The linear range, detection limit, and precision (R.S.D.) were 0.1-50 ng mL-1 (R2 = 0.9955), 0.601 ng mL-1 and 6.4%, respectively. The proposed method was validated with the real water samples,and the spiked recoveries were in the range of 69.9-89.8%, respectively. These results indicated that the established method withhigh enrichment factor, short extraction time was an excellent alternative for the routine analysis of atrazine in environmentalsamples.

  20. Solid phase microextraction (SPME) sampling under turbulent conditions and for the simultaneous collecting of tracer gases

    Institute of Scientific and Technical Information of China (English)

    Underwood Susanne W.; Jong Edmund C.; Luxbacher Kray D.; Sarver Emily A.; Ripepi Nino S.; McNair Harold M.

    2015-01-01

    Solid phase microextraction (SPME) is a solvent-free method of sample collection. SPME is an appealing method for sample collection because it is designed for the sampling of trace level analytes with short sampling times in a variety of environments. Additionally, SPME can be used to directly deliver a sample to a gas chromatograph (GC) for analysis by means of thermal desorption. In this paper, the performance of SPME under dynamic conditions was investigated. Additionally, the competence of SPME sampling for the simultaneous analysis of multiple trace analytes was also evaluated. This work is discussed in the context of underground mine ventilation surveys but is applicable to any industry in which ventilation circuits must be evaluated. The results of this paper showed that the performance of the 100 lm PDMS SPME fiber was both precise and rapid under dynamic conditions. This SPME fiber was also able to simultaneously collect sulfur hexafluoride (SF6) and perfluoromethylcyclohexane (PMCH) with adequate sensitivity.

  1. A digital microfluidic interface between solid-phase microextraction and liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Choi, Kihwan; Boyacı, Ezel; Kim, Jihye; Seale, Brendon; Barrera-Arbelaez, Luis; Pawliszyn, Janusz; Wheeler, Aaron R

    2016-04-29

    We introduce a method to couple solid-phase microextraction (SPME) with HPLC-MS using digital microfluidics (DMF). In the new system, SPME fibers are used to extract analytes from complex sample solutions, after which the analytes are desorbed into solvent droplets in a DMF device. The open geometry of DMF allows straightforward insertion of SPME fibers without requiring a complicated interface, and automated droplet manipulation enables multiplexed processing of the fibers. In contrast to other multiplexed SPME elution interfaces, the low volumes inherent to DMF allow for pre-concentration of analytes prior to analysis. The new SPME-DMF-HPLC-MS method was applied to the quantification of pg/mL-level free steroid hormones in urine. We propose that this new method will be useful for a wide range of applications requiring cleanup and pre-concentration with convenient coupling to high-performance analytical techniques.

  2. Thermal desorption solid-phase microextraction inlet for differential mobility spectrometry.

    Science.gov (United States)

    Rainsberg, Matthew R; de Harrington, Peter B

    2005-06-01

    A splitless thermal desorber unit that interfaces a differential mobility spectrometry (DMS) sensor has been devised. This device was characterized by the detection of benzene, toluene, and xylene (BTX) in water. The detection of BTX in water is important for environmental monitoring, and ion mobility measurements are traditionally difficult for hydrocarbons in water because water competes for charge and quenches the hydrocarbon signals. This paper reports the use of a DMS with a photoionization source that is directly coupled to a solid-phase microextraction (SPME) desorber. The separation and detection capabilities of the DMS were demonstrated using BTX components. Detection limits for benzene, toluene, and m-xylene were 75, 50, and 5 microg mL(-1), respectively.

  3. Biomonitoring of benzene and toluene in human blood by headspace-solid-phase microextraction

    Energy Technology Data Exchange (ETDEWEB)

    Schimming, E.; Levsen, K. [Fraunhofer-Institut fuer Toxikologie und Aerosolforschung (ITA), Hannover (Germany); Koehme, C.; Schuermann, W. [Medizinische Hochschule Hannover (Germany). Abt. fuer Pneumologie

    1999-01-01

    A simple and rapid method for the determination of benzene and toluene in whole blood by headspace-solid-phase microextraction (HS-SPME) is described. Using SPME fibres coated with 65 {mu}m carboxene/polydimethylsiloxane, limits of quantification (LOQ) of 5 ng/L for benzene and 25 ng/L for toluene are achieved. As a result of its large linear range (i.e. 5-5000 ng/L for benzene) the method is suitable for biomonitoring of both occupationally and environmentally exposed people. The reproducibility of the determination of benzene is {<=} 8%. An interlaboratory comparison demonstrated that the method proposed here compares favorably with existing methods (dynamic headspace, purge and trap). (orig.) With 2 figs., 2 tabs., 10 refs.

  4. Multiple headspace-solid-phase microextraction: An application to quantification of mushroom volatiles

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Rosaria; Tedone, Laura; De Grazia, Selenia [Dipartimento Farmaco-chimico, University of Messina, viale Annunziata, 98168 Messina (Italy); Dugo, Paola [Dipartimento Farmaco-chimico, University of Messina, viale Annunziata, 98168 Messina (Italy); Centro Integrato di Ricerca (C.I.R.), Università Campus-Biomedico, Via Álvaro del Portillo, 21, 00128 Roma (Italy); Mondello, Luigi, E-mail: lmondello@unime.it [Dipartimento Farmaco-chimico, University of Messina, viale Annunziata, 98168 Messina (Italy); Centro Integrato di Ricerca (C.I.R.), Università Campus-Biomedico, Via Álvaro del Portillo, 21, 00128 Roma (Italy)

    2013-04-03

    Highlights: ► Multiple headspace extraction-solid phase microextraction (MHS-SPME) has been applied to the analysis of Agaricus bisporus. ► Mushroom flavor is characterized by the presence of compounds with a 8-carbon atoms skeleton. ► Formation of 8-carbon compounds involves a unique fungal biochemical pathway. ► The MHS-SPME allowed to determine quantitatively 5 target analytes of A. bisporus for the first time. -- Abstract: Multiple headspace-solid phase microextraction (MHS-SPME) followed by gas chromatography/mass spectrometry (GC–MS) and flame ionization detection (GC–FID) was applied to the identification and quantification of volatiles released by the mushroom Agaricus bisporus, also known as champignon. MHS-SPME allows to perform quantitative analysis of volatiles from solid matrices, free of matrix interferences. Samples analyzed were fresh mushrooms (chopped and homogenized) and mushroom-containing food dressings. 1-Octen-3-ol, 3-octanol, 3-octanone, 1-octen-3-one and benzaldehyde were common constituents of the samples analyzed. Method performance has been tested through the evaluation of limit of detection (LoD, range 0.033–0.078 ng), limit of quantification (LoQ, range 0.111–0.259 ng) and analyte recovery (92.3–108.5%). The results obtained showed quantitative differences among the samples, which can be attributed to critical factors, such as the degree of cell damage upon sample preparation, that are here discussed. Considerations on the mushrooms biochemistry and on the basic principles of MHS analysis are also presented.

  5. Characterization and semiquantitative analysis of volatiles in seedless watermelon varieties using solid-phase microextraction.

    Science.gov (United States)

    Beaulieu, John C; Lea, Jeanne M

    2006-10-04

    Seedless triploid watermelons have increased in popularity since the early 1990s, and the demand for seedless fruit is on the rise. Sweetness and sugars are crucial breeding focuses for fruit quality. Volatiles also play an important role; yet, we found no literature for seedless varieties and no reports using solid-phase microextraction (SPME) in watermelon. The objective of this experiment was to identify volatile and semivolatile compounds in five seedless watermelon varieties using carboxen divinylbenzene polydimethylsiloxane solid-phase microextraction (SPME) with gas chromatography-mass spectrometry (GC-MS). Fully ripe watermelon was squeezed through miracloth to produce rapid juice extracts for immediate headspace SPME GC-MS. Aldehydes, alcohols, ketones, and one furan (2-pentyl furan, a lipid oxidation product) were recovered. On the basis of total ion count peak area, the most abundant compounds in five varieties were 3-nonen-1-ol/(E,Z)-2,6-nonadienal (16.5-28.2%), (E)-2-nonenal (10.6-22.5%), and (Z)-6-nonenal (2.0-11.3%). Hexanal was most abundant (37.7%) in one variety (Petite Perfection) [corrected] The most abundant ketone was 6-methyl-5-hepten-2-one (2.7-7.7%). Some sensory attributes reported for these compounds are melon, citrus, cucumber, orange, rose, floral, guava, violet, vegetable, green, grassy, herbaceous, pungent, fatty, sweet, and waxy. Identifying and relating these compounds to sensory attributes will allow for future monitoring of the critical flavor compounds in seedless watermelon after processing and throughout fresh-cut storage.

  6. Supramolecular solvent-based vortex-mixed microextraction: determination of glucocorticoids in water samples.

    Science.gov (United States)

    Qin, Hui; Qiu, Xiaoyan; Zhao, Jiao; Liu, Mousheng; Yang, Yaling

    2013-10-11

    Glucocorticoids contamination has become a big environmental issue in China and other developing countries, due to increasing needs in medical prescription and farming. However, no highly sensitive and precise methods have been reported to quantify glucocorticoids so far. In the past several years, supramolecular solvent-based vortex-mixed microextraction (SS-BVMME) has been shown to be effective. However, the mechanism of SS-BVMME is still unknown. In this report, a novel method has been proposed for rapid quantification of trace amount of glucocorticoids, beclomethasone dipropionate (BD), hydrocortisone butyrate (HB) and nandrolone phenylpropionate (NPP) in water samples from the Green Lake. This method is simple, safe and cost effective. It contains two steps: supramolecular solvent-based vortex-mixed microextraction (SS-BVMME) technique and high performance liquid chromatography (HPLC) analysis. First, ionic liquids 1-butyl-3-methylimidazolium tetrafluoroborate ([BMIM]BF4) and n-butanol were mixed to form the supramolecular solvent. After mixing the supramolecular solvent with an aqueous sample to test, a homogenous mixture was formed immediately. BD, HB and NPP were then extracted based on their binding interactions, particularly hydrogen bond formed between their hydroxyl group and the supramolecular solvent. The overall process of sample preparation took only 20min and more than 5 samples could be simultaneously prepared. The minimum detectable concentrations of samples in this method were 0.09925, 0.5429 and 2.428ngmL(-1) for BD, HB and NPP, respectively. Product recoveries ranged from 88% to 103% with relative standard deviations from 0.6% to 4%. For the first time, we report that hydrogen bond plays a key role in SS-BVMME. We also improve the sensitivity significantly to quantify glucocorticoids, which may greatly benefit environmental safety management in China.

  7. Cold fiber solid-phase microextraction device based on thermoelectric cooling of metal fiber.

    Science.gov (United States)

    Haddadi, Shokouh Hosseinzadeh; Pawliszyn, Janusz

    2009-04-03

    A new cold fiber solid-phase microextraction device was designed and constructed based on thermoelectric cooling. A three-stage thermoelectric cooler (TEC) was used for cooling a copper rod coated with a poly(dimethylsiloxane) (PDMS) hollow fiber, which served as the solid-phase microextraction (SPME) fiber. The copper rod was mounted on a commercial SPME plunger and exposed to the cold surface of the TEC, which was enclosed in a small aluminum box. A heat sink and a fan were used to dissipate the generated heat at the hot side of the TEC. By applying an appropriate dc voltage to the TEC, the upper part of the copper rod, which was in contact to the cold side of the TEC, was cooled and the hollow fiber reached a lower temperature through heat transfer. A thermocouple was embedded in the cold side of the TEC for indirect measurement of the fiber temperature. The device was applied in quantitative analysis of off-flavors in a rice sample. Hexanal, nonanal, and undecanal were chosen as three off-flavors in rice. They were identified according to their retention times and analyzed by GC-flame ionization detection instrument. Headspace extraction conditions (i.e., temperature and time) were optimized. Standard addition calibration graphs were obtained at the optimized conditions and the concentrations of the three analytes were calculated. The concentration of hexanal was also measured using a conventional solvent extraction method (697+/-143ng/g) which was comparable to that obtained from the cold fiber SPME method (644+/-8). Moreover, the cold fiber SPME resulted in better reproducibility and shorter analysis time. Cold fiber SPME with TEC device can also be used as a portable device for field sampling.

  8. A metal organic framework-polyaniline nanocomposite as a fiber coating for solid phase microextraction.

    Science.gov (United States)

    Bagheri, Habib; Javanmardi, Hasan; Abbasi, Alireza; Banihashemi, Solmaz

    2016-01-29

    A metal organic framework-polyaniline (MOF/PANI) nanocomposite was electrodeposited on a stainless steel wire and used as a solid phase microextraction (SPME) fiber coating. The electropolymerization process was carried out under a constant deposition potential and applied to the corresponding aqueous electrolyte containing aniline and MOF particles. The employment of MOFs with their large and small cages and 3-D structures in synthesizing a nanocomposite was assumed to be efficient constitutes to induce more non-smooth and porous structures, approved by scanning electron microscopy (SEM) images. Three different MOFs were incorporated to synthesize the desired nanocomposites and the preliminary experiments showed that all of them, particularly the one containing MOF2, have higher extraction performances in compared with PANI. The applicability of the new fiber coating was examined by headspace-solid phase microextraction (HS-SPME) of some chlorobenzenes (CBs) from aqueous samples. Influencing parameters on the synthesize and extraction processes including the electrodeposition voltage and its duration time, the weight ratio of PANI and MOF, the ionic strength, desorption temperature and time, and extraction time and temperature were optimized. The developed method was validated by analyzing the spiked distilled water and gas chromatography-mass spectrometry (GC-MS). Under optimum condition, the relative standard deviation (RSD%) values for a double distilled water spiked with the selected CBs at 20ngL(-1) were 5-8% (n=3) and the detection limits were below 0.2ngL(-1). The linear dynamic range (LDR) of the method was in the concentration range of 0.5-1000ngL(-1) (R(2)>0.9994). The fiber-to-fiber reproducibility was found to be in the range of 4-7%. Eventually, various real-water samples were analyzed by the MOF/PANI-based HS-SPME and GC-MS and the relative recovery values were found to be in the range of 92-98%.

  9. Determination of volatile organic compounds in water using headspace knotted hollow fiber microextraction.

    Science.gov (United States)

    Chen, Pai-Shan; Tseng, Yu-Hsiang; Chuang, Yuh-Lin; Chen, Jung-Hsuan

    2015-05-22

    An efficient and effective headspace microextraction technique named static headspace knotted hollow fiber microextraction (HS-K-HFME) has been developed for the determination of volatile organic compounds (VOCs) in water samples. The knot-shaped hollow fiber is filled with 25μL of the extraction solvent. The excess solvent forms a large droplet (13μL) and is held in the center of the knot. Even after 20min of extraction time at high temperature (95°C) without cooling, there was still enough volume of extraction solvent for gas chromatography-mass spectrometry (GC-MS) analysis, which extends the choice of solvents for headspace LPME. Moreover, the knot-shaped fiber has a larger extraction contact interface, which increases the rate of mass transfer between the headspace and extraction solvent film attached to the fiber, thus improving the extraction efficiency. The effects of extraction solvent, temperature, stirring rate, salt concentration and extraction time on extraction performance were optimized. The calibration curves exhibited coefficients of determination (R(2)) ranging from 0.9957 to 0.9999 and the limit of detection (LOD) ranged from 0.2 to 10μgL(-1). Relative standard deviations (RSDs) ranged from 4.5% to 11.6% for intraday measurements (n=5). Interday (n=15) values were between 2.2% and 12.9%. The relative recoveries (RRs) ranged from 90.3% to 106.0% for river water and 95.9% to 103.6% for wastewater.

  10. Fuel spill identification using solid-phase extraction and solid-phase microextraction. 1. Aviation turbine fuels.

    Science.gov (United States)

    Lavine, B K; Brzozowski, D M; Ritter, J; Moores, A J; Mayfield, H T

    2001-12-01

    The water-soluble fraction of aviation jet fuels is examined using solid-phase extraction and solid-phase microextraction. Gas chromatographic profiles of solid-phase extracts and solid-phase microextracts of the water-soluble fraction of kerosene- and nonkerosene-based jet fuels reveal that each jet fuel possesses a unique profile. Pattern recognition analysis reveals fingerprint patterns within the data characteristic of fuel type. By using a novel genetic algorithm (GA) that emulates human pattern recognition through machine learning, it is possible to identify features characteristic of the chromatographic profile of each fuel class. The pattern recognition GA identifies a set of features that optimize the separation of the fuel classes in a plot of the two largest principal components of the data. Because principal components maximize variance, the bulk of the information encoded by the selected features is primarily about the differences between the fuel classes.

  11. Identification of dimethoate-containing water using partitioned dispersive liquid-liquid microextraction coupled with near-infrared spectroscopy.

    Science.gov (United States)

    Zhang, Ming; Geng, Ying; Xiang, Bingren

    2011-01-01

    A simple, rapid and efficient extraction procedure, partitioned dispersive liquid-liquid microextraction, has been developed in combination with near-infrared spectroscopy for the extraction and discrimination of dimethoate from aqueous samples. For this technique, the appropriate mixture of extraction solvent (CCl(4)) and disperser solvent (THF) was utilized. Partial least squares discriminant analysis was applied to build the model with several pre-process methods over the wavenumber regions between 7100 cm(-1) to 7300 cm(-1). The best model gave satisfactory classification accuracy, 98.6% for calibration set (n=74) and 97.6% for prediction set (n=42), using preprocessing of standard normal variate followed by Savitzky-Golay first derivative. The method was successfully applied to bottled water, tap water, lake water and farm water samples. The results demonstrated the possibility of near-infrared spectroscopy after partitioned dispersive liquid-liquid microextraction for the identification of water contaminated by dimethoate.

  12. Headspace solvent microextraction-gas chromatography-mass spectrometry for the analysis of volatile compounds from Foeniculum vulgare Mill.

    Science.gov (United States)

    Fang, Lianghua; Qi, Meiling; Li, Ting; Shao, Qinglong; Fu, Ruonong

    2006-06-07

    A novel and rapid headspace solvent microextraction followed by gas chromatography-mass spectrometry (HSME-GC-MS) for the analysis of the volatile compounds of Foeniculum vulgare Mill is described. HSME parameters including extracting solvent, extraction temperature and time, headspace volume and particle size were optimized. As a result, benzyl alcohol was finally used for the extraction at 70 degrees C for 20 min with headspace volume of 12.1 ml and particle size of 120 mesh. Under the determined conditions, the powered samples of Foeniculum vulgare Mill were directly applied for the analysis. A comparison of HSME-GC-MS, solid phase microextraction (SPME)-GC-MS and steam distillation (SD)-GC-MS methods was made and showed that the HSME-GC-MS method was simple, inexpensive and effective and can be used for the analysis of volatile compounds in traditional Chinese medicines (TCMs).

  13. Identification and Quantification of Aldehydes in Mezcal by Solid Phase Microextraction with On-fiber Derivatization - Gas Cromatography

    OpenAIRE

    Guadalupe Medina Valtierra; Rocío Juárez Ciprés; Araceli Peña Álvarez

    2011-01-01

    A headspace solid phase microextraction with on fiber derivatization procedure followed by gas chromatography and flame ionization detection was applied for the determination of aldehydes in mezcal. A derivatization agent o-(2,3,4,5,6-pentafluorobenzyl) hydroxylamine (PFBHA) was adsorbed onto a Polydimethylsiloxane/ divinyl benzene (PDMS/DVB, 65 ¿m) fiber and exposed to the headspace of a vial with a mezcal sample. The aldehydes selectively reacted with PFBHA, and the oximes were desorbed int...

  14. Improvement of Liquid-phase Microextraction Method%分散液相微萃取方法的改进

    Institute of Scientific and Technical Information of China (English)

    林燕玲

    2011-01-01

    本文探讨了一种利用毛细管进行液相微萃取的新方法,对萃取剂体积、乳化剂体积、盐溶液浓度等影响因素进行了考察,并用该方法萃取水溶液的苯甲酸并用气相色谱氢火焰离子化检测器(GC-FID)进行检测,以甲苯作为萃取剂,乙醚作为乳化剂,得到校正曲线的线性r2为0.9951,回收率为101.8%,检出限为0.082g/L。%A new liquid-phase microextraction technique which employs capillary is developed in this dissertation.The benzoic acid water solution was utilized to assess the new liquid-phase microextraction method.After microextraction,the target compounds were separated and determined by the GC-FID.The effects of some extraction parameters such as the volume of solvent,the volume of emulsifier and the salt were studied.The new microextraction method provides a good linearity while toluene and diethyl ether were employed as the extraction solvent and emulsifier,respectively.Studies showed that the r2 for the calibration curve is 0.9954,recovery is 101.8% and LOD is 0.082g/L.

  15. Elemental analysis by surface-enhanced Laser-Induced Breakdown Spectroscopy combined with liquid–liquid microextraction

    OpenAIRE

    Aguirre Pastor, Miguel Ángel; Legnaioli, Stefano; Almodóvar, F.; Hidalgo Núñez, Montserrat; Palleschi, Vincenzo; Canals Hernández, Antonio

    2013-01-01

    In this work, the possibility of using Laser-Induced Breakdown Spectrometry (LIBS) combined with liquid–liquid microextraction techniques is evaluated as a simple and fast method for trace elemental analysis. Two different strategies for LIBS analysis of manganese contained in microdroplets of extraction solvent (Triton X-114) are studied: (i) analysis by direct laser irradiation of microdroplets; and (ii) analysis by laser irradiation of microdroplets dried on metallic substrates (surface-en...

  16. Rapid Separation of Elemental Species by Fast Multicapillary Gas Chromatography with Multichannel Optical Spectrometry Detection following Headspace Solid Phase Microextraction

    OpenAIRE

    Jacek Giersz; Krzysztof Jankowski; Monika Truskolaska

    2015-01-01

    A method for conducting fast and efficient gas chromatography based on short multicapillaries in straight alignment combined with atomic emission detection was developed for field analysis. The strategy enables for speciation analysis of organometallic compounds. The analytes are simultaneously ethylated and preconcentrated on a solid phase microextraction (SPME) fiber placed in the headspace over the sample for 25 min. The ethylated species are then completely separated and selectively quant...

  17. Solid-phase microextraction for determination of anilino-pyrimidine, dimethylcarbamate and thiadiazine pesticides in irrigation project surface water

    OpenAIRE

    Silva Filho,Clóvis F; Emídio,Elissandro S.; Dórea,Haroldo S.

    2011-01-01

    The objective of this work was to develop a solid-phase microextraction (SPME) technique for the determination of residues of the pyrimethanil, pirimicarb and buprofezin pesticides in surface waters from irrigated areas, with analysis by gas chromatography-mass spectrometry (GC-MS). The optimized method used a 100 µm polydimethylsiloxane (PDMS) fiber, agitation speed of the sample of 900 rpm and pH 7.0. Extraction and desorption times were 30 and 7 min, respectively. Linearity was achieved in...

  18. Vortex-assisted liquid-liquid microextraction for the rapid screening of short-chain chlorinated paraffins in water.

    Science.gov (United States)

    Chang, Chia-Yu; Chung, Wu-Hsun; Ding, Wang-Hsien

    2016-01-01

    The rapid screening of trace levels of short-chain chlorinated paraffins in various aqueous samples was performed by a simple and reliable procedure based on vortex-assisted liquid-liquid microextraction combined with gas chromatography and electron capture negative ionization mass spectrometry. The optimal vortex-assisted liquid-liquid microextraction conditions for 20 mL water sample were as follows: extractant 400 μL of dichloromethane; vortex extraction time of 1 min at 2500 × g; centrifugation of 3 min at 5000 × g; and no ionic strength adjustment. Under the optimum conditions, the limit of quantitation was 0.05 μg/L. Precision, as indicated by relative standard deviations, was less than 9% for both intra- and inter-day analysis. Accuracy, expressed as the mean extraction recovery, was above 91%. The vortex-assisted liquid-liquid microextraction with gas chromatography and electron capture negative ionization mass spectrometry method was successfully applied to quantitatively extract short-chain chlorinated paraffins from samples of river water and the effluent of a wastewater treatment plant, and the concentrations ranged from 0.8 to 1.6 μg/L.

  19. Switchable polarity solvent for liquid phase microextraction of Cd(II) as pyrrolidinedithiocarbamate chelates from environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Yilmaz, Erkan, E-mail: kimyager_erkan@hotmail.com; Soylak, Mustafa, E-mail: soylak@erciyes.edu.tr

    2015-07-30

    A switchable polarity solvent was synthesized from triethylamine (TEA)/water/CO{sub 2} (Dry ice) via proton transfer reaction has been used for the microextraction of cadmium(II) as pyrrolidinedithiocarbamate (APDC) chelate. Cd(II)-APDC chelate was extracted into the switchable polarity solvent drops by adding 2 mL 10 M sodium hydroxide solution. Analytical parameters affecting the complex formation and microextraction efficiency such as pH, amount of ligand, volume of switchable polarity solvent and NaOH, sample volume were optimized. The effects of foreign ions were found tolerably. Under optimum conditions, the detection limit was 0.16 μg L{sup −1} (3Sb/m, n = 7) and the relative standard deviation was 5.4% (n = 7). The method was validated by the analysis of certified reference materials (TMDA-51.3 fortified water, TMDA-53.3 fortified water and SPS-WW2 waste water, 1573a Tomato Leaves and Oriental Basma Tobacco Leaves (INCT-OBTL-5)) and addition/recovery tests. The method was successfully applied to determination of cadmium contents of water, vegetable, fruit and cigarette samples. - Highlights: • Switchable polarity solvent was synthesized from triethylamine (TEA)/water/CO{sub 2}. • The switchable polarity solvent has been used for the microextraction of cadmium(II). • The important factors were optimized. • The method was applied to determination of cadmium in real samples.

  20. Determination of arsenic and selenium by hydride generation and headspace solid phase microextraction coupled with optical emission spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Tyburska, Anna; Jankowski, Krzysztof, E-mail: kj@ch.pw.edu.pl; Rodzik, Agnieszka

    2011-07-15

    A hydride generation headspace solid phase microextraction technique has been developed in combination with optical emission spectrometry for determination of total arsenic and selenium. Hydrides were generated in a 10 mL volume septum-sealed vial and subsequently collected onto a polydimethylsiloxane/Carboxen solid phase microextraction fiber from the headspace of sample solution. After completion of the sorption, the fiber was transferred into a thermal desorption unit and the analytes were vaporized and directly introduced into argon inductively coupled plasma or helium microwave induced plasma radiation source. Experimental conditions of hydride formation reaction as well as sorption and desorption of analytes have been optimized showing the significant effect of the type of the solid phase microextraction fiber coating, the sorption time and hydrochloric acid concentration of the sample solution on analytical characteristics of the method developed. The limits of detection of arsenic and selenium were 0.1 and 0.8 ng mL{sup -1}, respectively. The limit of detection of selenium could be improved further using biosorption with baker's yeast Saccharomyces cerevisiae for analyte preconcentration. The technique was applied for the determination of total As and Se in real samples.

  1. Combination of counter current salting-out homogenous liquid-liquid extraction and dispersive liquid-liquid microextraction as a novel microextraction of drugs in urine samples.

    Science.gov (United States)

    Akramipour, Reza; Fattahi, Nazir; Pirsaheb, Meghdad; Gheini, Simin

    2016-02-15

    The counter current salting-out homogenous liquid-liquid extraction (CCSHLLE) joined with the dispersive liquid-liquid microextraction based on solidification of floating organic drop (DLLME-SFO) has been developed as a high preconcentration technique for the determination of different drugs in urine samples. Amphetamines were employed as model compounds to assess the extraction procedure and were determined by high performance liquid chromatography-ultraviolet detection (HPLC-UV). In this method, initially, NaCl as a separation reagent is filled into a small column and a mixture of urine and acetonitrile is passed through the column. By passing the mixture, NaCl is dissolved and the fine droplets of acetonitrile are formed due to salting-out effect. The produced droplets go up through the remained mixture and collect as a separated layer. Then, the collected acetonitrile is removed with a syringe and mixed with 30.0μL 1-undecanol (extraction solvent). In the second step, the 5.00mLK2CO3 solution (2% w/v) is rapidly injected into the above mixture placed in a test tube for further DLLME-SFO. Under the optimum conditions, calibration curves are linear in the range of 1-3000μgL(-1) and limit of detections (LODs) are in the range of 0.5-2μgL(-1). The extraction recoveries and enrichment factors ranged from 78 to 84% and 157 to 168, respectively. Repeatability (intra-day) and reproducibility (inter-day) of method based on seven replicate measurements of 100μgL(-1) of amphetamines were in the range of 3.5-4.5% and 4-5%, respectively. The method was successfully applied for the determination of amphetamines in the actual urine samples. The relative recoveries of urine samples spiked with amphetamine and methamphetamine are 90-108%.

  2. Risk assessment on liquid based cytology test and human papilloma virus L1 Nuclecapsid protein detection in the diagnosis of cervical lesions and its progress

    Institute of Scientific and Technical Information of China (English)

    Ling-Zhi Chen

    2016-01-01

    Objective: To discuss the clinical value of liquid based cytology test in the diagnosis of cervical lesions and to evaluate the expression difference and significance of human papilloma virus L1(HPV L1) protein in exfoliative cells of different cervical lesions. Methods: A total of 1 400 cases of patients in gynaecological clinics of our hospital from January 2009 to August 2013 were selected and were given liquid based cytology test(LCT) examination and HPV L1 protein expression detection in exfoliative cells. Meanwhile, cervical biopsy pathology results were taken as baseline for make a comparison. Results: (1) In such1400 cases of women: LCT(+)-30 cases, accounting for 2.1%, HPV L1 protein detection(+)-18 cases, accounting for 1.29%; LCT and HPV L1 protein detection(+)-8 cases, LCT and HPV L1 protein detection(-)- 1360 cases. (2)Pathological tissue biopsy was performed on 30 cases of patients with LCT(+), results showed that(+)were 23 cases; pathological tissue biopsy was performed on 18 cases of patients with HPV L1 protein(+),results showed that (+)were 14 cases. Among 1 360 cases with LCT and HPV L1 protein detection(-), 497 cases were willing to accept the pathological biopsy, and the results showed that 1 case presented(+), accounting for 0.2%. Total 545 cases were willing to accept the pathological biopsy, among whom, 38 cases presented(+), accounting for 6.97%;(3)Sensitivity and specificity of LCT combined with HPV L1 protein detection were higher than single-method detection, and difference had statistical significance. Conclusion: liquid based cytology test combined with HPV L1 protein detection could improve the diagnostic rate of cervical lesions, and were expected as the effective method in the early clinical screening of cervical neoplasia lesions.

  3. Long-term stability of human genomic and human papillomavirus DNA stored in BD SurePath and Hologic PreservCyt liquid-based cytology media.

    Science.gov (United States)

    Agreda, Patricia M; Beitman, Gerard H; Gutierrez, Erin C; Harris, James M; Koch, Kristopher R; LaViers, William D; Leitch, Sharon V; Maus, Courtney E; McMillian, Ray A; Nussbaumer, William A; Palmer, Marcus L R; Porter, Michael J; Richart, Gregory A; Schwab, Ryan J; Vaughan, Laurence M

    2013-08-01

    We evaluated the effect of storage at 2 to 8°C on the stability of human genomic and human papillomavirus (HPV) DNA stored in BD SurePath and Hologic PreservCyt liquid-based cytology media. DNA retained the ability to be extracted and PCR amplified for more than 2.5 years in both medium types. Prior inability to detect DNA in archived specimens may have been due to failure of the extraction method to isolate DNA from fixed cells.

  4. Could alarmingly high rates of negative diagnoses in remote rural areas be minimized with liquid-based citology? preliminary results from the RODEO study team

    OpenAIRE

    Fregnani, José Humberto; Neto, Cristovam Scapulatempo; Haikel Junior, Raphael L.; Saccheto, T.; Campacci, N.; Mauad, Edmund C.; Longatto Filho, Adhemar

    2013-01-01

    Objective: It was the aim of this study to compare diagnostic performances of the BD SurePath (TM) liquid-based Papanicolaou test (LBC) and the conventional Papanicolaou test (CPT) in cervical samples of women from remote rural areas of Brazil. Study Design: Specimens were collected by mobile units provided by Barretos Cancer Hospital. This report evaluates the manual screening arm of the RODEO study. Of 12,048 women seen between May and December 2010, 6,001 were examined using LBC and 6,047 ...

  5. Long-Term Stability of Human Genomic and Human Papillomavirus DNA Stored in BD SurePath and Hologic PreservCyt Liquid-Based Cytology Media

    Science.gov (United States)

    Agreda, Patricia M.; Beitman, Gerard H.; Gutierrez, Erin C.; Harris, James M.; Koch, Kristopher R.; LaViers, William D.; Leitch, Sharon V.; Maus, Courtney E.; McMillian, Ray A.; Nussbaumer, William A.; Palmer, Marcus L. R.; Porter, Michael J.; Richart, Gregory A.; Schwab, Ryan J.

    2013-01-01

    We evaluated the effect of storage at 2 to 8°C on the stability of human genomic and human papillomavirus (HPV) DNA stored in BD SurePath and Hologic PreservCyt liquid-based cytology media. DNA retained the ability to be extracted and PCR amplified for more than 2.5 years in both medium types. Prior inability to detect DNA in archived specimens may have been due to failure of the extraction method to isolate DNA from fixed cells. PMID:23678069

  6. 8781例宫颈液基细胞学分析%Liquid-based cytology test analysis of 8 781 cervical cases

    Institute of Scientific and Technical Information of China (English)

    王红群

    2014-01-01

    Objective To investigate the characteristics of cervical intraepithelial lesions through analyzing the liquid -based cytology test results of 8 781 cases.Methods We used liquid-based cytology test,and the criteria of the Bethesda system (TBS) were adopted. The abnormal cytological examination results of 199 cases were compared with those of histopathological results .Results Four hundred and ten cases(4.7%) had squamous epithelial lesions which were positively correlative with patients ’age(r=0.105,P=0.036). Three cases(0.03%) had glandular epithelium lesions .Liquid-based cytology test had high positive accuracy with histopathological re-sult of biopsy .Conclusions Adult women should be regularly examined by liquid-based cytology test in order to find precancerous le-sions as early as possible and have early treatment .%目的:分析8781例宫颈液基细胞学检查结果及其与组织学检测的相关性。方法采用宫颈液基细胞学检查,细胞学诊断采用TBS进行分析,199例异常细胞学检查与活检组织学进行对比分析。结果410例(4.7%)标准有鳞状上皮病变,3例(0.03%)有腺上皮病变,细胞的鳞状上皮病变与年龄大小呈正相关(r=0.105,P=0.036)。活检与细胞学检查阳性符合率高。结论成年女性应常规做宫颈液基细胞学检查,以便早期发现癌前病变,及时治疗。

  7. Intravascular large B-cell lymphoma involving mainly the uterus: report of a case using liquid-based cytology of the endometrium.

    Science.gov (United States)

    Fujiwara, Arisa; Nagayama, Shiho; Amada, Satoshi; Shimamoto, Tomihiro; Shimao, Yoshiya; Hayashi, Tohru

    2010-01-01

    Intravascular lymphoma is a rare subtype of extranodal lymphoma. Most instances of the disease are of B-cell lineage. Diagnosis is difficult because of its nonspecific clinical signs, and many cases are diagnosed at autopsy. Uterine involvement is rare, and it is commonly manifested as genital bleeding. In this case, the chief complaint was fever, which is also very rare. A 62-year-old woman presented with fever of unknown origin. Computed tomography revealed no localized lesion except for swelling of the right internal iliac nodes. A cytologic smear of the endometrium by liquid-based cytology demonstrated malignant cells. Based on the curettage material, the lesion was diagnosed as an undifferentiated malignant tumor. Total abdominal hysterectomy with bilateral salpingo-oophorectomy and pelvic/paraaortic lymphadenectomy revealed widely scattered lymphoma cells of B-cell lineage mainly in the vascular lumina of the uterus, right ovary and lymph nodes. The final histologic type was established on the basis of the surgical material of hysterectomy. Diagnosis was difficult because of prominent cellular atypia and rare location of the tumor. Immunocytochemical examination of liquid-based samples can lead to a correct diagnosis of malignant lymphoma, even at the stage of endometrial cytologic examination.

  8. Should liquid-based cytology be performed prior to colposcopy? A comparison of the accuracy, unsatisfactory rates and cost in a tertiary referral setting.

    Science.gov (United States)

    Angstetra, Donald; Tait, Thomas; Tan, Jeffrey; Symonds, Ian

    2009-12-01

    To compare the use of liquid-based cytology (LBC) with conventional cytology (CC) in the assessment cervical intraepithelial neoplasia (CIN) prior to colposcopy. Retrospective Cohort Study. Liquid-based cytology and CC findings were compared with colposcopic assessment and directed cervical biopsy in terms of sensitivity and specificity for high grade lesions only and for any abnormalities. The degree of correlation was sought. Secondary outcomes were unsatisfactory rate and cost. A total of 1961 women had colposcopy of whom 528 had cervical biopsy. LBC and CC have similar sensitivity and specificity for both high-grade lesions and any abnormalities. In comparison with cervical biopsy, LBC and CC sensitivity for high-grade disease was 89.1% and 88.6% respectively and for any abnormalities, the sensitivity was 86.6% and 87.0%. Specificity for high-grade disease was 83.1% and 84.7% and for any abnormalities, the specificity was 53.8% and 56.4%. The unsatisfactory rate was significantly lower in LBC 4.38% compared to 1.84% (P < 0.001). However, the use of LBC was associated with an additional cost of A$1496 for each unsatisfactory smear avoided. In high prevalence setting, LBC showed no statistically significant difference in sensitivity and specificity from CC for the detection of CIN. A reduction in unsatisfactory smears was evident, but at significant additional cost.

  9. Comparative study of manual liquid-based cytology (MLBC) technique and direct smear technique (conventional) on fine-needle cytology/fine-needle aspiration cytology samples.

    Science.gov (United States)

    Pawar, Prajkta Suresh; Gadkari, Rasika Uday; Swami, Sunil Y; Joshi, Anil R

    2014-04-01

    Liquid-based cytology technique enables cells to be suspended in a liquid medium and spread in a monolayer, making better morphological assessment. Automated techniques have been widely used, but limited due to cost and availability. The aim was to establish manual liquid-based cytology (MLBC) technique on fine-needle aspiration cytology (FNAC) material and compare its results with conventional technique. In this study, we examined cells trapped in needles hub used for the collection of FNAC samples. 50 cases were examined by the MLBC technique and compared with the conventional FNAC technique. By centrifugation, sediment was obtained and imprint was taken on defined area. Papanicolaou (Pap) and May-Grünwald Giemsa (MGG) staining was done. Direct smears and MLBC smears were compared for cellularity, background, cellular preservation, and nuclear preservation. Slides were diagnosed independently by two cytologists with more than 5 years' experience. Standard error of proportion was used for statistical analysis. Cellularity was low in MLBC as compared with conventional smears, which is expected as remnant material in the needle hub was used. Nuclei overlap to a lesser extent and hemorrhage and necrosis was reduced, so cell morphology can be better studied in the MLBC technique. P value obtained was <0.05. This MLBC technique gives results comparable to the conventional technique with better morphology. In a set up where aspirators are learners, this technique will ensure adequacy due to remnant in needle hub getting processed.

  10. A comparative study between conventional and liquid-based cytology in screening for anal intraepithelial lesions in HIV-positive patients.

    Science.gov (United States)

    Maia, Livia Bravo; Marinho, Larissa Cardoso; Wanderley Paes Barbosa, Tania; Batalha Filho, Eronides Salustiano; Ribeiro Velasco, Lara Franciele; Garcia Costa, Patrícia Godoy; Carneiro, Fabiana Pirani; de Oliveira, Paulo Gonçalves

    2014-10-01

    Anal intraepithelial neoplasia (AIN) is associated with HPV infection and can be detected by cytological screening. While conventional exfoliative cytology (CC) is a low-cost and nonaggressive method, liquid-based cytology (LBC) tends to give clearer readings. Although studies of the efficacy of anal cancer screening methods would be of great importance for groups at high risk for AIN, few such studies have been conducted. The aim of the present study was to assess the concordance of CC and LBC in diagnosing anal pre-neoplastic lesions, and to compare cytological results with anoscopy, histopathological, and molecular biology findings. Comparative study involving 33 HIV-positive patients, who underwent anoscopy and biopsy of suspected lesions. Concordance between the two cytology methods was calculated, as were the associations between cytology results and findings from other screening methods. A total of 54.5% of cases were considered AIN-negative by CC and LBC, and concordance between the two methods was statistically significant (P liquid-based cytology are equally effective in screening for anal preneoplastic lesions. © 2014 Wiley Periodicals, Inc.

  11. Ionic Liquid-Based Ultrasonic-Assisted Extraction of Secoisolariciresinol Diglucoside from Flaxseed (Linum usitatissimum L.) with Further Purification by an Aqueous Two-Phase System.

    Science.gov (United States)

    Tan, Zhi-Jian; Wang, Chao-Yun; Yang, Zi-Zhen; Yi, Yong-Jian; Wang, Hong-Ying; Zhou, Wan-Lai; Li, Fen-Fang

    2015-09-30

    In this work, a two-step extraction methodology of ionic liquid-based ultrasonic-assisted extraction (IL-UAE) and ionic liquid-based aqueous two-phase system (IL-ATPS) was developed for the extraction and purification of secoisolariciresinol diglucoside (SDG) from flaxseed. In the IL-UAE step, several kinds of ILs were investigated as the extractants, to identify the IL that affords the optimum extraction yield. The extraction conditions such as IL concentration, ultrasonic irradiation time, and liquid-solid ratio were optimized using response surface methodology (RSM). In the IL-ATPS step, ATPS formed by adding kosmotropic salts to the IL extract was used for further separation and purification of SDG. The most influential parameters (type and concentration of salt, temperature, and pH) were investigated to obtain the optimum extraction efficiency. The maximum extraction efficiency was 93.35% under the optimal conditions of 45.86% (w/w) IL and 8.27% (w/w) Na₂SO₄ at 22 °C and pH 11.0. Thus, the combination of IL-UAE and IL-ATPS makes up a simple and effective methodology for the extraction and purification of SDG. This process is also expected to be highly useful for the extraction and purification of bioactive compounds from other important medicinal plants.

  12. Ionic liquid-based extraction followed by graphite-furnace atomic absorption spectrometry for the determination of trace heavy metals in high-purity iron metal.

    Science.gov (United States)

    Matsumiya, Hiroaki; Kato, Tatsuya; Hiraide, Masataka

    2014-02-01

    The analysis of high-purity materials for trace impurities is an important and challenging task. The present paper describes a facile and sensitive method for the determination of trace heavy metals in high-purity iron metal. Trace heavy metals in an iron sample solution were rapidly and selectively preconcentrated by the extraction into a tiny volume of an ionic liquid [1-butyl-3-methylimidazolium bis(trifluoromethanesulfonyl)imide] for the determination by graphite-furnace atomic absorption spectrometry (GFAAS). A nitrogen-donating neutral ligand, 2,4,6-tris(2-pyridyl)-1,3,5-triazine (TPTZ), was found to be effective in the ionic liquid-based selective extraction, allowing the nearly complete (~99.8%) elimination of the iron matrix. The combination with the optimized GFAAS was successful. The detectability reached sub-μg g(-1) levels in iron metal. The novel use of TPTZ in ionic liquid-based extraction followed by GFAAS was successfully applied to the determination of traces of Co, Ni, Cu, Cd, and Pb in certified reference materials for high-purity iron metal. © 2013 Published by Elsevier B.V.

  13. Preparation and selective recognition of a novel solid-phase microextraction fiber combined with molecularly imprinted polymers for the extraction of parabens in soy sample.

    Science.gov (United States)

    He, Juan; Chen, Si; Jiang, Yili; Shen, Yanzheng; Zhu, Jing; Wei, Hongliang; Zhang, Hongxia; Lu, Kui

    2012-01-01

    A prepared molecularly imprinted polymer with ethyl p-hydroxybenzoate as template molecule was applied for the first time to a homemade solid-phase microextraction fiber. The molecularly imprinted polymer-coated solid-phase microextraction fiber was characterized by scanning electron microscopy and thermogravimetric analysis. Various parameters were investigated, including extraction temperature, extraction time, and desorption time. Under the optimum extraction conditions, the molecularly imprinted polymer-coated solid-phase microextraction fiber exhibited higher selectivity with greater extraction capacity toward parabens compared with the nonimprinted polymer-coated solid-phase microextraction fiber and commercial fibers. The molecularly imprinted polymer-coated solid-phase microextraction fiber was tested using gas chromatography to determine parabens, including methyl p-hydroxybenzoate, ethyl p-hydroxybenzoate, and propyl p-hydroxybenzoate. The linear ranges were 0.01-10 μg/mL with a correlation coefficient above 0.9943. The detection limits (under signal-to-noise ratio of 3) were below 0.30 μg/L. The fiber was successfully applied to the simultaneous analysis of three parabens in spiked soy samples with satisfactory recoveries of 95.48, 97.86, and 92.17%, respectively. The relative standard deviations (n=6) were within 2.83-3.91%. The proposed molecularly imprinted polymer-coated solid-phase microextraction method is suitable for selective extraction and determination of trace parabens in food samples. Copyright © 2012 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. SOLID PHASE MICROEXTRACTION AND ITS APPLICATION IN EXPLOSIVE ANALYSIS%固相微萃取技术及其在炸药检测中的应用

    Institute of Scientific and Technical Information of China (English)

    刘红妮; 张婷; 严蕊; 杨彩宁

    2011-01-01

    评述了固相微萃取技术的工作原理、操作模式、影响因素,介绍了固相微萃取技术在炸药分析如炸药蒸气分析和炸药残留分析中的应用情况,展望了这一技术的应用前景.%Operation principle, operation mode, influence factors of solid phase microextraction technique were reviewed.Solid phase microextraction application in explosive analysis included explosive envolved gas and explosive residues analysis were introuduced. Its future development was also discussed.

  15. Derivatisation/solid-phase microextraction followed by gas chromatography-mass spectrometry for the analysis of phenoxy acid herbicides in aqueous samples

    DEFF Research Database (Denmark)

    Nilsson, Torben; Baglio, Daniela; Galdo-Miguez, Isabel

    1998-01-01

    Different combinations of derivatisation and solid-phase microextraction followed by gas chromatography-mass spectrometry were optimised and evaluated for the analysis of phenoxy acid herbicides in water. The most successful derivatisation approach was aqueous-phase derivatisation with benzyl...... bromide. The benzyl esters were extracted most efficiently by the solid-phase microextraction fibre coated with polydimethylsiloxane-divinylbenzene. No carry-over problems were encountered with this fibre upon desorption at 250 degrees C. Detection limits in the ng/l range were obtained, while...

  16. Comparison of air-agitated liquid-liquid microextraction technique and conventional dispersive liquid-liquid micro-extraction for determination of triazole pesticides in aqueous samples by gas chromatography with flame ionization detection.

    Science.gov (United States)

    Farajzadeh, Mir Ali; Mogaddam, Mohammad Reza Afshar; Aghdam, Abdollah Abdollahi

    2013-07-26

    Two micro-extraction methods, air-agitated liquid-liquid microextraction (AALLME) and dispersive liquid-liquid microextraction (DLLME), have been compared with each other by applying them for the analysis of five triazole pesticides (penconazole, hexaconazole, diniconazole, tebuconazole and triticonazole) in aqueous samples by gas chromatography with flame ionization detection (GC-FID). In the AALLME method, which excludes any disperser solvent, much less volume of organic solvent is used. In order to form fine and dispersed organic droplets in the aqueous phase, the mixture of aqueous sample solution and extraction solvent is repeatedly aspirated and dispensed with a syringe. In the DLLME method, an appropriate mixture of extraction solvent and disperser solvent is rapidly injected by a syringe into the aqueous sample. Effect of the pertinent experimental factors on DLLME (i.e. identity and volume of the extraction and disperser solvents and ionic strength) and on AALLME (identity and volume of the extraction solvent, number of agitations, and ionic strength) were investigated. Under optimal conditions, limits of detection for the five target pesticides obtained by AALLME-GC-FID and DLLME-GC-FID ranged from 0.20 to 1.1ngmL(-1) and 1.9 to 5.9ngmL(-1), respectively. The relative standard deviations (RSDs, n=5) were in the range of 1-4% and 3-5% with the enrichment factors of 449-504 and 79-143 for AALLME-GC-FID and DLLME-GC-FID, respectively. Both of the compared methods are simple, fast, efficient, inexpensive and can be applied to the analysis of the five pesticides in different aqueous samples in which penconazole and hexaconazole were found. For spiked samples, the recoveries were in the ranges of 92-105%, and 92-104% for AALLME and DLLME, respectively.

  17. Comparison of hollow fiber liquid-phase microextraction and ultrasound-assisted low-density solvent dispersive liquid-liquid microextraction for the determination of drugs of abuse in biological samples by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Meng, Liang; Zhang, Wenwen; Meng, Pinjia; Zhu, Binling; Zheng, Kefang

    2015-05-01

    Two microextraction techniques based on hollow fiber liquid-phase microextraction (HF-LPME) and ultrasound-assisted low-density solvent dispersive liquid-liquid microextraction (UA-LDS-DLLME) had been applied for the determination of drugs of abuse (methamphetamine, amphetamine, 3,4-methylenedioxymethamphetamine, 3,4-methylenedioxyamphetamine, methcathinone, ketamine, meperidine, and methadone) in urine and blood samples by gas chromatography-mass spectrometry. Parameters affecting extraction efficiency have been investigated and optimized for both methods. Under the optimum conditions, linearities were observed for all analytes in the range 0.0030-10 μg/ml with the correlation coefficient (R) ranging from 0.9985 to 0.9995 for HF-LPME and in the range 0.0030-10 μg/ml with the R ranging from 0.9985 to 0.9994 for DLLME. The recovery of 79.3-98.6% with RSDs of 1.2-4.5% was obtained for HF-LPME, and the recovery of 79.3-103.4% with RSDs of 2.4-5.7% was obtained for DLLME. The LODs (S/N=3) were estimated to be in the range from 0.5 to 5 ng/ml and 0.5 to 4 ng/ml, respectively. Compared with HF-LPME, the UA-LDS-DLLME technique had the advantages of less extraction time, suitability for batches of sample pretreatment simultaneously, and higher extraction efficiency, while HF-LPME has excellent sample clean-up effect, and is a robust and suitable technique for various sample matrices with better repeatability. Both methods were successfully applied to the analysis of drugs of abuse in real human blood sample.

  18. Rapid detection of haloarchaeal carotenoids via liquid-liquid microextraction enabled direct TLC MALDI-MS.

    Science.gov (United States)

    Manikandan, Muthu; Hasan, Nazim; Wu, Hui-Fen

    2013-03-30

    For the first time, we demonstrate the use of TiO2 nanoparticles (NPs) for enhancing the carotenoid production by the extremophilic haloarchea, Haloferax mediterranei. TiO2 NPs at optimal concentration of 375 mg/L results in a 95% increase in the production of carotenoid pigment compared to the control (no TiO2 NPs). The carotenoid pigments extracted from TiO2 NPs treated H. mediterranei cells, were separated using thin layer chromatography (TLC). The separated carotenoid spots were subjected directly for MALDI MS detection. To limit the sample diffusion during matrix addition on TLC plates, a simple bordering mode was exercised. Using this method we were able to detect the pigments successfully using MALDI-MS, directly from TLC plates after separation. In addition, we also applied the Pt NPs capped with ODT via Liquid-liquid microextraction (LLME) for extracting the pigment molecules from the halobacteria in MALDI-MS. These novel NP approaches possess numerous advantages such as; rapidity, ease in synthesis, high sensitivity and low cost. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Insight into the extraction mechanism of polymeric ionic liquid sorbent coatings in solid-phase microextraction.

    Science.gov (United States)

    Ho, Tien D; Cole, William T S; Augusto, Fabio; Anderson, Jared L

    2013-07-12

    An investigation into the mechanism of extraction for polymeric ionic liquid (PIL)-based solid phase microextraction sorbent coatings is described. Four PIL-based coatings, namely, a poly(1-4-vinylbenzyl)-3-hexadecylimidazolium bis[(trifluoromethyl)sulfonyl] imide (poly([VBHDIM][NTf2])) PIL produced through 2,2'-azo-bis(isobutyronitrile) (AIBN) initiated free-radical polymerization, a UV-initiated poly(1-vinyl-3-hexylimidazolium) chloride (poly([VHIM][Cl])) PIL, and two crosslinked PILs containing the same IL monomers copolymerized with dicationic IL crosslinkers, were investigated. Calibration curves of 1-octanol were plotted in the presence of naphthalene, a model interfering compound, to observe changes in the linear range, sensitivity, and amount of analytes extracted. Results were compared with a polydimethylsiloxane/divinylbenzene (PDMS/DVB) coating and a polyacrylate (PA) coating which are known to extract analytes primarily through adsorption and partitioning mechanisms, respectively. All PIL-based coatings extracted analytes via a non-competitive partitioning mechanism regardless of the extent of crosslinking.

  20. Crosslinked polymeric ionic liquids as solid-phase microextraction sorbent coatings for high performance liquid chromatography.

    Science.gov (United States)

    Yu, Honglian; Merib, Josias; Anderson, Jared L

    2016-03-18

    Neat crosslinked polymeric ionic liquid (PIL) sorbent coatings for solid-phase microextraction (SPME) compatible with high-performance liquid chromatography (HPLC) are reported for the first time. Six structurally different PILs were crosslinked to nitinol supports and applied for the determination of select pharmaceutical drugs, phenolics, and insecticides. Sampling conditions including sample solution pH, extraction time, desorption solvent, desorption time, and desorption solvent volume were optimized using design of experiment (DOE). The developed PIL sorbent coatings were stable when performing extractions under acidic pH and remained intact in various organic desorption solvents (i.e., methanol, acetonitrile, acetone). The PIL-based sorbent coating polymerized from the IL monomer 1-vinyl-3-(10-hydroxydecyl) imidazolium chloride [VC10OHIM][Cl] and IL crosslinker 1,12-di(3-vinylbenzylimidazolium) dodecane dichloride [(VBIM)2C12] 2[Cl] exhibited superior extraction performance compared to the other studied PILs. The extraction efficiency of pharmaceutical drugs and phenolics increased when the film thickness of the PIL-based sorbent coating was increased while many insecticides were largely unaffected. Satisfactory analytical performance was obtained with limits of detection (LODs) ranging from 0.2 to 2 μg L(-1) for the target analytes. The accuracy of the analytical method was examined by studying the relative recovery of analytes in real water samples, including tap water and lake water, with recoveries varying from 50.2% to 115.9% and from 48.8% to 116.6%, respectively.

  1. A new interface for coupling solid phase microextraction with liquid chromatography.

    Science.gov (United States)

    Chen, Yong; Sidisky, Leonard M

    2014-03-19

    A modified Rheodyne 7520 microsample injector was used as a new solid phase microextraction (SPME)-liquid chromatography (LC) interface. The modification was focused on the construction of a new sample rotor, which was built by gluing two sample rotors together. The new sample rotor was further reinforced with 3 pieces of stainless steel tubing. The enlarged central flow passage in the new sample rotor was used as a desorption chamber. SPME fiber desorption occurred in static mode. But all desorption solvent in the desorption chamber was injected into LC system with the interface. The analytical performance of the interface was evaluated by SPME-LC analysis of PAHs in water. At least 90% polycyclic aromatic hydrocarbons (PAHs) were desorbed from a polyacrylonitrile (PAN)/C18 bonded fuse silica fiber in 30s. And injection was completed in 20s. About 10-20% total carryovers were found on the fiber and in the interface. The carryover in the interface was eliminated by flushing the desorption chamber with acetonitrile at 1mL min(-1) for 2min. The repeatability of the method was from 2% to 8%. The limit of detection (LOD) was in the mid pg mL(-1) range. The linear ranges were from 0.1 to 100ng mL(-1). The new SPME-LC interface was reliable for coupling SPME with LC for both qualitative and quantitative analysis.

  2. Determination of fipronil by solid-phase microextraction and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Vílchez, J L; Prieto, A; Araujo, L; Navalón, A

    2001-06-01

    A method for the determination of trace amounts of the insecticide fipronil was developed using solid-phase microextraction-gas chromatography-mass spectrometry and selected ion monitoring. Fipronil was extracted with a fused-silica fiber coated with 85 microm polyacrylate. The effects of pH, ionic strength, sample volume, extraction and desorption times as well as the extraction temperature were studied. Lindane was used as an internal standard. The linear concentration range of application was 0.3-100 ng ml(-1) of fipronil, with a relative standard deviation of 9.5% (for a level of 50 ng ml(-1)) and a detection limit of 0.08 ng ml(-1). The method was applied to check the eventual existence of fipronil above this limit in water and soil samples from Granada (Spain) as well as in human urine samples. The method validation was completed with spiked matrix samples. The method can be applied as a monitoring tool for water, soil and urine, in the investigation of environmental and occupational exposure to fipronil.

  3. Liquid Phase Micro-Extraction of Linear Alkylbenzene Sulfonate Anionic Surfactants in Aqueous Samples

    Directory of Open Access Journals (Sweden)

    Jan Åke Jönsson

    2011-10-01

    Full Text Available Hollow fiber liquid phase micro-extraction (LPME of linear alkylbenzene sulfonates (LAS from aqueous samples was studied. Ion pair extraction of C10, C11, C12 and C13 homologues was facilitated with trihexylamine as ion-pairing agent, using di-n-hexylether as solvent for the supported liquid membrane (SLM. Effects of extraction time, acceptor buffer concentration, stirring speed, sample volume, NaCl and humic acids were studied. At 10–50 µg L−1 linear R2-coefficients were 0.99 for C10 and C11 and 0.96 for C12. RSD was typically ~15%. Three observations were especially made. Firstly, LPME for these analytes was unusually slow with maximum enrichment observed after 15–24 h (depending on sample volume. Secondly, the enrichment depended on LAS sample concentration with 35–150 times enrichment below ~150 µg L−1 and 1850–4400 times enrichment at 1 mg L−1. Thirdly, lower homologues were enriched more than higher homologues at low sample concentrations, with reversed conditions at higher concentrations. These observations may be due to the fact that LAS and the amine counter ion themselves influence the mass transfer at the water-SLM interface. The observations on LPME of LAS may aid in LPME application to other compounds with surfactant properties or in surfactant enhanced membrane extraction of other compounds.

  4. Sol-gel molecularly imprinted polymer for selective solid phase microextraction of organophosphorous pesticides.

    Science.gov (United States)

    Wang, Yu-Long; Gao, Yuan-Li; Wang, Pei-Pei; Shang, Huan; Pan, Si-Yi; Li, Xiu-Juan

    2013-10-15

    A sol-gel technique was applied for the preparation of water-compatible molecularly imprinted polymer (MIP) for solid phase microextraction (SPME) using diazinon as template and polyethylene glycol as functional monomer. The MIP-coated fiber demonstrated much better selectivity to diazinon and its structural analogs in aqueous cucumber sample than in distilled water, indicating its potential in real samples. Thanks to its specific adsorption as well as rough and porous surface, the coating revealed rather larger extraction capability than the non-imprinted polymer and commercial fibers. In addition, the fiber exhibited excellent thermal (about 350°C) and chemical stability (organic and inorganic). After optimization of several parameters affecting extraction efficiency, a method based on MIP-SPME combined with gas chromatography was developed for the determination of organophosphorus pesticides (OPPs) in vegetable samples. The limits of detection for the tested OPPs were in the range of 0.017-0.77 μg kg(-1). The proposed method was applied to evaluate OPPs in spiked cucumber, green pepper, Chinese cabbage, eggplant and lettuce samples, and recoveries of 81.2-113.5% were obtained by the standard addition method with three spiking levels in each kind of vegetable.

  5. Evaluation of electrochemically synthesized sulfadimethoxine-imprinted polymer for solid-phase microextraction of sulfonamides.

    Science.gov (United States)

    Díaz-Álvarez, Myriam; Mazzotta, Elisabetta; Malitesta, Cosimino; Martín-Esteban, Antonio

    2014-06-01

    Solid-phase microextraction (SPME) is widely used in analytical laboratories for the analysis of organic compounds, thanks to its simplicity and versatility. In the present work, the synthesis and evaluation of imprinted films for SPME by electropolymerisation of pyrrole alone or in the presence of ethylene glycol dimethacrylate is proposed. Sulfadimethoxine (SDM), a sulfonamide antibiotic, was used as template molecule. Initially, a molecularly imprinted polymer film was prepared by electropolymerisation of pyrrole onto a platinum foil, using SDM as template. The SDM template was removed by overoxidation. The behaviour of SDM on imprinted and non-imprinted polymers was investigated by differential pulse voltammetry, and a clear imprinting effect was observed, which was confirmed by rebinding experiments using both conventional and electrochemically enhanced-SPME. However, in general, the extraction efficiency was rather low (<6%) and unspecific interactions are too high. Attempts to increase extraction efficiency were unsuccessful, but the incorporation of ethylene glycol dimethacrylate to the films reduced unspecific interactions to a certain extent.

  6. Determination of phenolic compounds in honey using dispersive liquid-liquid microextraction.

    Science.gov (United States)

    Campone, Luca; Piccinelli, Anna Lisa; Pagano, Imma; Carabetta, Sonia; Di Sanzo, Rosa; Russo, Mariateresa; Rastrelli, Luca

    2014-03-21

    Honey is a valuable functional food rich in phenolic compounds with a broad spectrum of biological activities. Analysis of the phenolic compounds in honey is a very promising tool for the quality control, the authentication and characterization of botanical origin, and the nutraceutical research. This work describes a novel approach for the rapid analysis of five phenolic acids and 10 flavonoids in honey. Phenolic compounds were rapidly extracted and concentrated from diluted honey by dispersive liquid-liquid microextraction (DLLME) and then analyzed using high performance liquid chromatography with UV absorbance detection (HPLC-UV). Some important parameters, such as the nature and volume of extraction and dispersive solvents, pH and salt effect were carefully investigated and optimized to achieve the best extraction efficiency. Under the optimal conditions, an exhaustive extraction for twelve of the investigated analytes (recoveries >70%), with a precision (RSDDLLME to the extraction of other honey phytochemicals, such as abscisic acid, was also demonstrated. The main advantages of developed method are the simplicity of operation, the rapidity to achieve a very high sample throughput and low cost.

  7. Dispersive Liquid-Liquid Microextraction in the Analysis of Milk and Dairy Products: A Review

    Directory of Open Access Journals (Sweden)

    Andrew Quigley

    2016-01-01

    Full Text Available Dispersive liquid-liquid microextraction (DLLME is an extraction technique developed within the last decade, which involves the dispersion of fine droplets of extraction solvent in an aqueous sample. Partitioning of analytes into the extraction phase is instantaneous due to the very high collective surface area of the droplets. This leads to very high enrichment factors and very low solvent consumption, relative to other liquid or solid phase extraction methods. A comprehensive review of the various modes of DLLME in the analysis of organic and inorganic analytes in dairy products (milk, cheese, infant formula, yogurt, and breast milk is presented here. Dairy products present a complex sample matrix and the removal of interfering matrix components can prove troublesome. This review focuses on sample pretreatment prior to the appropriate DLLME procedure, the extraction and dispersive solvents chosen, derivatisation methods, and analytical figures of merit. Where possible, a critical comparison of DLLME methods has been undertaken. The overall suitability, and limitations, of DLLME as a sample preparation technique for dairy products has been assessed.

  8. Sequential dispersive liquid-liquid microextraction for the determination of aryloxyphenoxy-propionate herbicides in water.

    Science.gov (United States)

    Li, Songqing; Gao, Peng; Zhang, Jiaheng; Li, Yubo; Peng, Bing; Gao, Haixiang; Zhou, Wenfeng

    2012-12-01

    A novel dispersive liquid-liquid microextraction (DLLME) method followed by HPLC analysis, termed sequential DLLME, was developed for the preconcentration and determination of aryloxyphenoxy-propionate herbicides (i.e. haloxyfop-R-methyl, cyhalofop-butyl, fenoxaprop-P-ethyl, and fluazifop-P-butyl) in aqueous samples. The method is based on the combination of ultrasound-assisted DLLME with in situ ionic liquid (IL) DLLME into one extraction procedure and achieved better performance than widely used DLLME procedures. Chlorobenzene was used as the extraction solvent during the first extraction. Hydrophilic IL 1-octyl-3-methylimidazolium chloride was used as a dispersive solvent during the first extraction and as an extraction solvent during the second extraction after an in situ chloride exchange by bis[(trifluoromethane)sulfonyl]imide. Several experimental parameters affecting the extraction efficiency were studied and optimized with the design of experiments using MINITAB® 16 software. Under the optimized conditions, the extractions resulted in analyte recoveries of 78-91%. The correlation coefficients of the calibration curves ranged from 0.9994 to 0.9997 at concentrations of 10-300, 15-300, and 20-300 μg L(-1). The relative SDs (n = 5) ranged from 2.9 to 5.4%. The LODs for the four herbicides were between 1.50 and 6.12 μg L(-1).

  9. Ligandless-dispersive liquid-liquid microextraction of trace amount of copper ions

    Energy Technology Data Exchange (ETDEWEB)

    Mohammadi, Sayed Zia, E-mail: szmohammadi@yahoo.com [Department of Chemistry, Payame Noor University (PNU), Kerman (Iran, Islamic Republic of); Afzali, Daryoush [Environment Department, Institute Research of Environmental Sciences, International Center for Science, High Technology and Environmental Sciences, Kerman (Iran, Islamic Republic of); Baghelani, Yar Mohammad [Department of Chemistry, Payame Noor University (PNU), Kerman (Iran, Islamic Republic of)

    2009-10-27

    In the present work, a new ligandless-dispersive liquid-liquid microextraction (LL-DLLME) method has been developed for preconcentration trace amounts of copper as a prior step to its determination by flame atomic absorption spectrometry. In the proposed approach 1,2-dicholorobenzene and ethanol were used as extraction and dispersive solvents, respectively. Some factors influencing on the extraction efficiency of copper and its subsequent determination were studied and optimized, such as the extraction and dispersive solvent type and volume, pH of sample solution, extraction time and salting out effect. Under the optimal conditions, the calibration curve was linear in the range of 1.0 ng mL{sup -1}-0.6 {mu}g mL{sup -1} of copper with R{sup 2} = 0.9985. Detection limit was 0.5 ng mL{sup -1} in original solution (3S{sub b}/m) and the relative standard deviation for seven replicate determination of 0.2 {mu}g mL{sup -1} copper was {+-}1.4%. The proposed method has been applied for determination of copper in standard and water samples with satisfactory results.

  10. Dispersive liquid-liquid microextraction of thiram followed by microvolume UV-vis spectrophotometric determination

    Science.gov (United States)

    Rastegarzadeh, Saadat; Pourreza, Nahid; Larki, Arash

    2013-10-01

    A novel and simple method for the sensitive determination of trace amounts of fungicide thiram is developed by combination of dispersive liquid-liquid microextraction (DLLME) and microvolume UV-vis spectrophotometry. The method is based on the conversion of thiram to a yellow product in the presence of ethanolic potassium hydroxide and copper sulfate, and its extraction into CCL4 using DLLME technique. In this method the ethanol existing in ethanolic KOH plays as disperser solvent and a cloudy solution is formed by injection of only CCl4 as extractant solvent into sample solution. Under the optimum conditions, the calibration graph was linear over the range of 25-1000 ng mL-1 of thiram with limit of detection of 11.5 ng mL-1. The relative standard deviation (RSD) for 100 and 500 ng mL-1 of thiram was 2.7 and 1.1% (n = 8), respectively. The proposed method was successfully applied to determination of thiram in water and plant seed samples.

  11. Determination of tramadol by dispersive liquid-liquid microextraction combined with GC-MS.

    Science.gov (United States)

    Habibollahi, Saeed; Tavakkoli, Nahid; Nasirian, Vahid; Khani, Hossein

    2015-01-01

    Dispersive liquid-liquid microextraction (DLLME) coupled with gas chromatography-mass spectrometry (GC-MS) has been developed for preconcentration and determination of tramadol, ((±)-cis-2-[(dimethylamino)methyl]-1-(3-methoxyphenyl)cyclohexanol-HCl), in aqueous and biological samples (urine, blood). DLLME is a simple, rapid and efficient method for determination of drugs in aqueous samples. Efficient factors on the DLLME process has defined and optimized for extraction of tramadol including type of extraction and disperser solvents and their volumes, pH of donor phase, time of extraction and ionic strength of donor phase. Based on the results of this study, under optimal conditions and by using 2-nitro phenol as internal standard, tramadol was determined by GC-MS, and the figures of merit of this work were evaluated. The enrichment factor, relative recovery and limit of detection were obtained 420, 99.2% and 0.08 µg L(-1), respectively. The linear range was between 0.26 and 220.00 µg L(-1) (R(2) = 0.9970). The relative standard deviation for 50.00 µg L(-1) of tramadol in aqueous samples by using 2-nitro phenol as IS was 3.6% (n = 7). Finally, the performance of DLLME was evaluated for analysis of tramadol in urine and blood.

  12. Molecularly imprinted calixarene fiber for solid-phase microextraction of four organophosphorous pesticides in fruits.

    Science.gov (United States)

    Li, Jing-Wen; Wang, Yu-Long; Yan, Shan; Li, Xiu-Juan; Pan, Si-Yi

    2016-02-01

    Calixarene was used as a functional monomer to fabricate a molecularly imprinted polymer (MIP) by sol-gel technique for solid-phase microextraction (SPME) of parathion-methyl and its structural analogs. The MIP-coated fiber possessed excellent thermal and chemical stability as well as high extraction capacity. Its selectivity and possible recognition mechanism were investigated. The similarities in molecular shape and functional group play a key role in the selective recognition of the imprinted material. Any changes to the structure of the template would decrease the imprinting factor. A comparison of MIP-SPME was made with liquid-liquid extraction coupled with gas chromatography for the determination of organophosphorus pesticides (OPPs) in fruits. Much lower limits of detection and better recoveries were achieved by SPME in spiked apple and pineapple samples. The experiment demonstrates that the proposed method using the calixarene MIP fiber was more suitable for selective determination of trace OPPs in those fruit samples. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Facile preparation and applications of graphitic carbon nitride coating in solid-phase microextraction.

    Science.gov (United States)

    Xu, Na; Wang, Yiru; Rong, Mingcong; Ye, Zhifeng; Deng, Zhuo; Chen, Xi

    2014-10-17

    In this study, graphitic carbon nitride (g-C3N4) was used as a coating material for solid-phase microextraction (SPME) applications. Coupled to gas chromatography (GC), the extraction ability of the SPME fiber was investigated and compared with the commercial fibers of 100 μm PDMS and 85 μm CAR/PDMS using six target analytes including deltamethrin, nerolidol, amphetamine, dodecane, ametryn and acrylamide. The g-C3N4 coating revealed excellent extraction ability and durability comparing with those of the commercial fibers due to its loose structure and unique physicochemical properties. The repeatability for each single fiber was found to be 3.46% and reproducibility for fiber to fiber was 8.53%. The g-C3N4 SPME fiber was applied to the determination of acrylamide in potato chips, the linearity and detection limit was 0.5-250 μg g(-1) and 0.018 μg g(-1), respectively.

  14. In vivo fast equilibrium microextraction by stable and biocompatible nanofiber membrane sandwiched in microfluidic device.

    Science.gov (United States)

    Wu, Qian; Wu, Dapeng; Guan, Yafeng

    2013-12-03

    In vivo analysis poses higher requirements about the biocompatibility, selectivity and speed of analytical method. In this study, an in vivo fast equilibrium microextraction method was developed with a biocompatible core-sheath electrospun nanofiber membrane sandwiched within a microfluidic unit. The polystyrene/collagen core-sheath nanofiber membrane was coaxially electrospun and strengthened with in situ glutaraldehyde cross-linking. This membrane not only kept high mass transfer rate, large extraction capacity and biomatrix resistance as our previously proposed membrane (Anal. Chem. 2013, 85 (12), 5924-5932), but also got much better mechanical strength and stability in water. The microfluidic device was designed to sandwich the membrane, and the blood in vivo can be introduced into it and get contact with the membrane repetitively. With this membrane and device, a 2-min equilibrium in vivo extraction method was established, validated in a simulated blood circulation system, and was used to monitor the pharmacokinetic profiles of desipramine in rabbits. The free and total concentration of desipramine in vivo was monitored with 10-min interval almost without rabbit blood consumed. The results met well with those of in vitro extraction, and a correlation factor of 0.99 was obtained.

  15. Electrodeposited apatite coating for solid-phase microextraction and sensitive indirect voltammetric determination of fluoride ions.

    Science.gov (United States)

    Mao, Yuehong; Chen, Yufei; Chu, Lin; Zhang, Xiaoli

    2013-10-15

    Electrodeposition was used to prepare a new solid phase microextraction (SPME) coatings. Two apatite SPME coatings, dicalcium phosphate dihydrate (DCPD or brushite) and hydroxyapatite (HAP) were validly and homogeneously one-step electrodeposited on glassy carbon electrode (GCE) under different conditions. The coatings were characterized by XRD, FTIR, SEM, CV and EIS. The apatite SPME coatings showed excellent and selective adsorbability to fluoride ions. A novel indirect voltammetric strategy for sensitive detection of fluoride was proposed using K3Fe(CN)6 as indicating probe. The detection principle of fluoride ions was based on the increment of steric hindrance after fluoride adsorption, which resulting in the decrease of the amperometric signal to Fe(CN)6(3-). The liner ranges were 0.5-20.0 μmol/L for n-DCPD/GCE with the limit of detection of 0.14 μmol/L and 0.1-50.0 μmol/L for n-HAP/GCE with the limit of detection of 0.069 μmol/L, respectively. The developed method was applied to the analysis of water samples (lake, spring and tap water) and the recovery values were found to be in the range of 90-106%.

  16. Carbon nanotube-coated solid-phase microextraction metal fiber based on sol-gel technique.

    Science.gov (United States)

    Jiang, Ruifen; Zhu, Fang; Luan, Tiangang; Tong, Yexiang; Liu, Hong; Ouyang, Gangfeng; Pawliszyn, Janusz

    2009-05-29

    A novel carbon nanotube (CNT)-coated solid-phase microextraction fiber was prepared based on sol-gel technique. Commonly used fragile fused silica fiber was replaced with stainless steel wire, which made the fiber unbreakable. An approach was also proposed for batch producing, and good reproducibilities for fiber to fiber and between fibers were achieved. Experiments showed that the sol-gel-CNT fiber exhibited high thermal stability to resist 350 degrees C and excellent solvent durability in methanol and acetonitrile. Compared to commercial polydimethylsiloxane (PDMS) fiber, the sol-gel-CNT fiber represented significantly improved extraction efficiencies for both polar (phenols) and non-polar (benzene, toluene, ethylbenzene, and o-xylene) compounds. Meanwhile, no replacement effect, low carry-over and wide linear range demonstrated that the newly prepared sol-gel-CNT coating has liquid properties, which allow a relatively easy quantification procedure. Moreover, the characterization of the sol-gel-CNT coating was also evaluated with McReynold probe solutes. The results showed that the coating has better affinity for all the five types of solutes compared to commercial 7microm PDMS fiber, which suggested that the coating has the potential to be developed as GC stationary phase.

  17. Preparation and characterization of porous carbon material-coated solid-phase microextraction metal fibers.

    Science.gov (United States)

    Zhu, Fang; Guo, Jiaming; Zeng, Feng; Fu, Ruowen; Wu, Dingcai; Luan, Tiangang; Tong, Yexiang; Lu, Tongbu; Ouyang, Gangfeng

    2010-12-10

    Two kinds of porous carbon materials, including carbon aerogels (CAs), wormhole-like mesoporous carbons (WMCs), were synthesized and used as the coatings of solid-phase microextraction (SPME) fibers. By using stainless steel wire as the supporting core, six types of fibers were prepared with sol-gel method, direct coating method and direct coating plus sol-gel method. Headspace SPME experiments indicated that the extraction efficiencies of the CA fibers are better than those of the WMC fibers, although the surface area of WMCs is much higher than that of CAs. The sol-gel-CA fiber (CA-A) exhibited excellent extraction properties for non-polar compounds (BTEX, benzene, toluene, ethylbenzene, o-xylene), while direct-coated CA fiber (CA-B) presented the best performance in extracting polar compounds (phenols). The two CA fibers showed wide linear ranges, low detection limits (0.008-0.047μgL(-1) for BTEX, 0.15-5.7μgL(-1) for phenols) and good repeatabilities (RSDs less than 4.6% for BTEX, and less than 9.5% for phenols) and satisfying reproducibilities between fibers (RSDs less than 5.2% for BTEX, and less than 9.9% for phenols). These fibers were successfully used for the analysis of water samples from the Pearl River, which demonstrated the applicability of the home-made CA fibers.

  18. Headspace liquid-phase microextraction of methamphetamine and amphetamine in urine by an aqueous drop

    Energy Technology Data Exchange (ETDEWEB)

    He Yi [Department of Sciences, John Jay College of Criminal Justice, City University of New York, 445 W 59th Street, New York, NY 10019 (United States)]. E-mail: yhe@jjay.cuny.edu; Vargas, Angelica [Department of Sciences, John Jay College of Criminal Justice, City University of New York, 445 W 59th Street, New York, NY 10019 (United States); Kang, Youn-Jung [Department of Sciences, John Jay College of Criminal Justice, City University of New York, 445 W 59th Street, New York, NY 10019 (United States)

    2007-04-25

    This study developed a headspace liquid-phase microextraction (LPME) method by using a single aqueous drop in combination with high performance liquid chromatography (HPLC)-UV detection for the determination of methamphetamine (MAP) and amphetamine (AP) in urine samples. The analytes, volatile and basic, were released from sample matrix into the headspace first, and then protonated and dissolved in an aqueous H{sub 3}PO{sub 4} drop hanging in the headspace by a HPLC syringe. After extraction, this drop was directly injected into HPLC. Parameters affecting extraction efficiency were investigated and optimized. This method showed good linearity in the investigated concentration range of 1.0-1500 {mu}g L{sup -1}, repeatability of the extraction (R.S.D. < 5%, n = 6), and low detection limits (0.3 {mu}g L{sup -1} for both analytes). Enrichment factors of about 400-fold and 220-fold were achieved for MAP and AP, respectively, at optimum conditions. The feasibility of the method was demonstrated by analyzing human urine samples.

  19. Determination of amphetamines in biological samples using electro enhanced solid-phase microextraction-gas chromatography.

    Science.gov (United States)

    Zeng, Jingbin; Chen, Jingjing; Li, Min; Subhan, Fazle; Chong, Fayun; Wen, Chongying; Yu, Jianfeng; Cui, Bingwen; Chen, Xi

    2015-09-01

    In this work, an ordered mesoporous carbon (OMC)/Nafion coated fiber for solid-phase microextraction (SPME) was prepared and used as the working electrode for electro-enhanced SPME (EE-SPME) of amphetamines. The EE-SPME strategy is primarily based on the electro-migration and complementary charge interaction between fiber coating and ionic compounds. Compared with traditional SPME, EE-SPME exhibited excellent extraction efficiency for amphetamine (AP) and methamphetamine (MA) with an enhancement factor of 7.8 and 12.1, respectively. The present strategy exhibited good linearity for the determination of AP and MA in urine samples in the range of 10-1000ngmL(-1) and 20-1000ngmL(-1), respectively. The detection limits were found to be 1.2ngmL(-1) for AP and 4.8ngmL(-1) for MA. The relative standard deviations were calculated to be 6.2% and 8.5% for AP and MA, respectively. Moreover, the practical application of the proposed method was demonstrated by analyzing the amphetamines in urine and serum samples with satisfactory results.

  20. Application of solvent microextraction to the analysis of amphetamines and phencyclidine in urine.

    Science.gov (United States)

    Casari, C; Andrews, A R

    2001-09-01

    A fast and simple method to detect some commonly abused illicit drugs, amphetamine, methamphetamine, 3,4-methylendioxy-amphetamine (MDA), 3,4-methylendioxy-methamphetamine (MDMA), 3,4-methylendioxy-N-ethylamphetamine (MDEA) and phencyclidine (PCP) in urine using solvent microextraction (SME) combined with gas chromatography (GC) analysis has been developed. The extraction is conducted by suspending a 2 microl drop of chloroform in a 2 ml urine sample. Following 8 min of extraction, the organic solvent is withdrawn into the syringe and injected into a GC with a pulsed discharge helium ionization detector (PDHID). The effects of different extraction solvents and times, pH and sample preparation were studied. The optimized method was capable of detecting drugs in urine at concentrations below Substance Abuse and Mental Health Services Administration (SAMHSA) established cut-off values for preliminary testing. Good linearity and reproducibility of extraction were obtained. The limits of detection were 0.5 microg/ml for amphetamine, 0.1 microg/ml for methamphetamine and MDA, 0.05 microg/ml for MDMA, 0.025 microg/ml for MDEA and 0.015 microg/ml for PCP. Relative standard deviation (R.S.D.) values ranged between 5 and 20% for the studied drugs.

  1. [Application of solid-phase microextraction technique to the detection of amphetamines in urine by GC].

    Science.gov (United States)

    Liu, W; Shen, M

    1999-05-01

    A simple and rapid detection of nine amphetamines co-existing in urine was described. In the test, the method of solid-phase micro-extraction (SPME) by GC technique was used. Urine (1.0 ml), NaCl (0.3 g) and 4-phenylbutylamine (internal standard) were added into a vial (1.5 ml), then the sample was adjusted to pH 12 with 10% NaOH and sealed with a teflon-coated septum. After immersion of the SPME fiber (100 PDME) in the sample for 15 min, the SPME needle was inserted into the injection port of the GC and extruded for 3 min. The result showed that each peak from nine amphetamines compounds and internal standard was clearly separated. The calibration curves were linear from 0.2 to 15 micrograms/ml for most of five amphetamines with r between 0.9928-0.9995. The CV were less 10%. It is concluded that the method is simple, quick, accurate and useful for the practical detection of urine concentration of amphetamines.

  2. Solid-phase microextraction and chiral HPLC analysis of ibuprofen in urine.

    Science.gov (United States)

    de Oliveira, Anderson Rodrigo Moraes; Cesarino, Evandro José; Bonato, Pierina Sueli

    2005-04-25

    A simple and rapid solid-phase microextraction method was developed for the enantioselective analysis of ibuprofen in urine. The sampling was made with a polydimethylsiloxane-divinylbenzene coated fiber immersed in the liquid sample. After desorptioning from the fiber, ibuprofen enantiomers were analyzed by HPLC using a Chiralpak AD-RH column and UV detection. The mobile phase was made of methanol-pH 3.0 phosphoric acid solution (75:25, v/v), at a flow rate of 0.45 mL/min. The mean recoveries of SPME were 19.8 and 19.1% for (-)-R-ibuprofen and (+)-(S)-ibuprofen, respectively. The method was linear at the range of 0.25-25 microg/mL. Within-day and between-day assay precision and accuracy were below 15% for both ibuprofen enantiomers at concentrations of 0.75, 7.5 and 20 microg/mL. The method was tested with urine quality control samples and human urine fractions after administration of 200 mg rac-ibuprofen.

  3. Graphenized pencil lead fiber: facile preparation and application in solid-phase microextraction.

    Science.gov (United States)

    Liu, Qian; Cheng, Mengting; Long, Yanmin; Yu, Miao; Wang, Thanh; Jiang, Guibin

    2014-01-17

    Graphenized pencil lead fiber was facilely prepared by in situ chemical exfoliation of graphite in pencil lead fiber to few-layered graphene sheets via a one-pot, one-step pressurized oxidation reaction for the first time. This new fiber was characterized and demonstrated to be a highly efficient but low-cost solid-phase microextraction (SPME) fiber. The extraction performance of the fiber was evaluated with four bisphenol analogs [bisphenol A (BPA), bisphenol S (BPS), bisphenol AF (BPAF), and tetrabromobisphenol A (TBBPA)] as model analytes in direct SPME mode. Unlike commercially available fibers, the graphenized pencil lead fiber showed an excellent chemical stability in highly saline, acidic, alkaline and organic conditions due to its coating-free configuration. The fiber also showed a very long lifespan. Furthermore, high extraction efficiency and good selectivity for the analytes with a wide polarity range could be obtained due to the exceptional properties of graphene. The detection limits (LODs) for the analytes were in the range of 1.1-25ng/L. The fiber was successfully applied in the analysis of tap water and effluent samples from a waste water treatment plant with spike recoveries ranging from 68.5 to 105.1%. Therefore, the graphenized pencil lead fiber provides a high performance, cheap, robust, and reliable tool for SPME.

  4. Rapid determination of octanol-water partition coefficient using vortex-assisted liquid-liquid microextraction.

    Science.gov (United States)

    Román, Iván P; Mastromichali, Anna; Tyrovola, Konstantina; Canals, Antonio; Psillakis, Elefteria

    2014-02-21

    Vortex-assisted liquid-liquid microextraction (VALLME) coupled with high-performance liquid chromatography (HPLC) is proposed here for the rapid determination of octanol-water partitioning coefficients (Kow). VALLME uses vortex agitation, a mild emulsification procedure, to disperse microvolumes of octanol in the aqueous phase thus increasing the interfacial contact area and ensuring faster partitioning rates. With VALLME, 2min were enough to achieve equilibrium conditions between the octanolic and aqueous phases. Upon equilibration, separation was achieved using centrifugation and the octanolic microdrop was collected and analyzed in a HPLC system. Six model compounds with logKow values ranging between ∼0.5 and 3.5 were used during the present investigations. The proposed method produced logKow values that were consistent with previously published values and the recorded uncertainty was well within the acceptable log unit range. Overall, the key features of the proposed Kow determination procedure comprised speed, reliability, simplicity, low cost and minimal solvent consumption.

  5. Robust aptamer sol-gel solid phase microextraction of very polar adenosine from human plasma.

    Science.gov (United States)

    Mu, Li; Hu, Xiangang; Wen, Jianping; Zhou, Qixing

    2013-03-01

    Conventional solid phase microextraction (SPME) has a limited capacity to extract very polar analytes, such as adenosine. To solve this problem, aptamer conjugating sol-gel methodology was coupled with an SPME fiber. According to the authors' knowledge, this is the first reported use of aptamer SPME. The fiber of aptamer sol-gel SPME with a mesoporous structure has high porosity, large surface area, and small water contact angle. Rather than employing direct entrapment, covalent immobilization was the dominant method of aptamer loading in sol-gel. Aptamer sol-gel fiber captured a specified analyte from among the analog molecules, thereby, exhibiting an excellent selective property. Compared with commercial SPME fibers, this aptamer fiber was suitable for extracting adenosine, presenting an extraction efficiency higher than 20-fold. The values of repeatability and reproducibility expressed by relative standard deviation were low (9.4%). Interestingly, the sol-gel network enhanced the resistance of aptamer SPME to both nuclease and nonspecific proteins. Furthermore, the aptamer sol-gel fiber was applied in human plasma with LOQ 1.5 μg/L, which is an acceptable level. This fiber also demonstrates durability and regeneration over 20-cycles without significant loss of efficiency. Given the various targets (from metal ions to biomacromolecules and cells) of aptamers, this methodology will extend the multi-domain applications of SPME.

  6. Solid-phase microextraction for the analysis of short-chain chlorinated paraffins in water samples.

    Science.gov (United States)

    Castells, P; Santos, F J; Galceran, M T

    2003-01-10

    A novel solid-phase microextraction (SPME) method coupled to gas chromatography with electron capture detection (GC-ECD) was developed as an alternative to liquid-liquid and solid-phase extraction for the analysis of short-chain chlorinated paraffins (SCCPs) in water samples. The extraction efficiency of five different commercially available fibres was evaluated and the 100-microm polydimethylsiloxane coating was the most suitable for the absorption of the SCCPs. Optimisation of several SPME parameters, such as extraction time and temperature, ionic strength and desorption time, was performed. Quality parameters were established using Milli-Q, tap water and river water. Linearity ranged between 0.06 and 6 microg l(-1) for spiked Milli-Q water and between 0.6 and 6 microg l(-1) for natural waters. The precision of the SPME-GC-ECD method for the three aqueous matrices was similar and gave relative standard deviations (RSD) between 12 and 14%. The limit of detection (LOD) was 0.02 microg l(-1) for Milli-Q water and 0.3 microg l(-1) for both tap water and river water. The optimised SPME-GC-ECD method was successfully applied to the determination of SCCPs in river water samples.

  7. Graphene-coated fiber for solid-phase microextraction of triazine herbicides in water samples.

    Science.gov (United States)

    Wu, Qiuhua; Feng, Cheng; Zhao, Guangying; Wang, Chun; Wang, Zhi

    2012-01-01

    Graphene is a novel and interesting carbon material that could be used for the separation and purification of some chemical compounds. In this investigation, graphene was used as a novel fiber-coating material for the solid-phase microextraction (SPME) of four triazine herbicides (atrazine, prometon, ametryn and prometryn) in water samples. The main parameters that affect the extraction and desorption efficiencies, such as the extraction time, stirring rate, salt addition, desorption solvent and desorption time, were investigated and optimized. The optimized SPME by graphene-coated fiber coupled with high-performance liquid chromatography-diode array detection (HPLC-DAD) was successfully applied for the determination of the four triazine herbicides in water samples. The linearity of the method was in the range from 0.5 to 200 ng/mL, with the correlation coefficients (r) ranging from 0.9989 to 0.9998. The limits of detection of the method were 0.05-0.2 ng/mL. The relative standard deviations varied from 3.5 to 4.9% (n=5). The recoveries of the triazine herbicides from water samples at spiking levels of 20.0 and 50.0  ng/mL were in the range between 86.0 and 94.6%. Compared with two commercial fibers (CW/TPR, 50 μm; PDMS/DVB, 60 μm), the graphene-coated fiber showed higher extraction efficiency.

  8. Determination of particulate-bound formaldehyde from burning incense by solid phase microextraction.

    Science.gov (United States)

    Liou, S W; Chen, C Y; Yang, T T; Lin, J M

    2008-04-01

    This work studied the feasibility of using a solid phase microextraction (SPME) fiber for sampling and analysis of gaseous formaldehyde as well as particulate-bound formaldehyde from burning Chinese incense. The SPME fiber with PDMS/DVB coating were partially coated with o-(2,3,4,5,6-pentafluorobenzyl)-hydroxylamine hydrochloride (PFBHA), and used for sampling formaldehyde. The sampling rate for formaldehyde and its dependence on temperature, relative humidity and sampling time were observed. The same PFBHA treated fibers were, in parallel, exposed to incense burning smoke with pre-filtration and without pre- filtration for 0.5-1 min. The NIOSH method 2541 using an XAD-2 tube at a flow rate of 0.1 Lpm was also applied for sampling simultaneously. The results demonstrate that commercially available PDMS/DVB fibers partially coated with PFBHA are capable of sampling the gas phase of formaldehyde as well as particulate-bound formaldehyde. The determined level of formaldehyde was close to the result obtained by the NIOSH method 2541. However, a reduction of the fiber's formaldehyde loading capacity in the aerosol sampling in comparison with gas sampling was noticed. This indicates that the particulate characteristics, and their bound chemicals other than formaldehyde may influence the maximum loading capacity of formaldehyde, and some characteristic particulates in high concentrations may even deteriorate the fiber coating.

  9. Headspace Solid-Phase Microextraction Analysis of Volatile Components in Narcissus tazetta var. chinensis Roem

    Directory of Open Access Journals (Sweden)

    Hai-Shan Chi

    2013-11-01

    Full Text Available The volatile components in single-flowered and double-flowered Chinese narcissus were identified by headspace-solid phase microextraction (HS-SPME coupled with GC and GC/MS. Changes in aroma during the vase-life (days 0, 1, 2, 3, 4, 5 and 6 of two samples were also studied. A total of 35 compounds were identified, of which all were present in single-flowered and 26 in double-flowered samples. The main aroma components were (E-β-ocimene, and benzyl acetate. Single-flowered narcissus have a higher percentage of benzyl acetate, while double-flowered narcissus have a higher percentage of 1,8-cineole. In vase-life, the total volatile component content peaked on day 2 for single-flowered and day 3 for the double-flowered narcissus. For both single-flowered and double-flowered narcissus flowers, the total content of volatile components had decreased significantly by day 4.

  10. A Longitudinal Study of Decomposition Odour in Soil Using Sorbent Tubes and Solid Phase Microextraction

    Directory of Open Access Journals (Sweden)

    Katelynn A. Perrault

    2014-07-01

    Full Text Available Odour profiling of decomposed remains is important for understanding the mechanisms that cadaver dogs and forensically-relevant insects use to locate decomposed remains. The decomposition odour profile is complex and has been documented in outdoor terrestrial environments. The purpose of this study was to perform longitudinal analysis of the volatile organic compound (VOC profile in soils associated with decomposed remains across all stages of decomposition. Two VOC collection techniques (sorbent tubes and solid phase microextraction were used to collect a wider analyte range and to investigate differences in collection techniques. Pig carcasses were placed in an outdoor research facility in Australia to model the decomposition process and VOCs were collected intermittently over two months. VOCs of interest were identified over the duration of the trial, showing distinct trends in compound evolution and disappearance. The collection techniques were complementary, representing different subsets of VOCs from the overall profile. Sorbent tubes collected more decomposition-specific VOCs and these compounds were more effective at characterising the matrix over an extended period. Using both collection techniques improves the likelihood of identifying the complete VOC profile of decomposition odour. Such information is important for the search and recovery of victim remains in various stages of decomposition.

  11. Volatile profile of yellow passion fruit juice by static headspace and solid phase microextraction techniques

    Directory of Open Access Journals (Sweden)

    Gilberto Costa Braga

    2015-02-01

    Full Text Available The profile of volatile compounds of yellow passion fruit juice was analyzed by solid phase microextraction headspace (HS-SPME and optimized static headspace (S-HS extraction techniques. Time, temperature, NaCl concentration and sample volume headspace equilibrium parameters was adjusted to the S-HS technique. The gaseous phase in the headspace of samples was collected and injected into a gas chromatograph coupled to a mass spectrometer. In the HS-SPME technique was identified 44 volatile compounds from the yellow passion fruit juice, but with S-HS only 30 compounds were identified. Volatile esters were majority in both techniques, being identified ethyl butanoate, ethyl hexanoate, (3z-3-hexenyl acetate, hexyl acetate, hexyl butanoate and hexyl hexanoate. Aldehydes and ketones were not identified in S-HS, but were in HS-SPME. β-Pinene, p-cymene, limonene, (Z-β-ocimene, (E-β-ocimene, γ-terpinene, α-terpinolene and (E -4,8-dimethyl-1, 3,7 - nonatriene terpenes were identified in both techniques. This study showed that the S-HS optimized extraction technique was effective to recovery high concentrations of the major volatile characteristics compounds in the passion fruit, such as ethyl butanoate and ethyl hexanoate, which can be advantageous due to the simplicity of the method.

  12. Study of complex matrix effect on solid phase microextraction for biological sample analysis.

    Science.gov (United States)

    Jiang, Ruifen; Xu, Jianqiao; Zhu, Fang; Luan, Tiangang; Zeng, Feng; Shen, Yong; Ouyang, Gangfeng

    2015-09-11

    Solid phase microextraction (SPME) has become a useful tool for in vivo monitoring the behavior of environmental organic pollutants in biological species due to its simplicity, relatively non-invasive, and cost-effective manner. However, the complex matrices in biological samples could significantly influence the extraction kinetic, and bias the quantification result. In this study, we investigated the effect of complex matrix on the extraction kinetic of SPME for biological sample analysis. Two sample matrices, phosphate-buffered saline (PBS) with bovine serum albumin (BSA) and agarose gel with BSA were used to simulate the biological fluid and tissue. Results showed that the addition of BSA significantly enhanced the mass transfer of organic compounds onto SPME fiber in both PBS buffer and gel sample. Enhancement factors ranging from 1.3 to 27, and 2.0 to 80 were found for all selected polyaromatic hydrocarbons (PAHs) in PBS buffer and agarose gel with BSA concentration of 0.1-5%, respectively. Then, an improved theoretical model was applied to quantify the observed enhancement effect, and the result showed that the predicted sampling time constant agreed well with the experimental one in complex matrix. Furthermore, a simplified equation was proposed for the real biological sample analysis.

  13. Magnetism-Enhanced Monolith-Based In-Tube Solid Phase Microextraction.

    Science.gov (United States)

    Mei, Meng; Huang, Xiaojia; Luo, Qing; Yuan, Dongxin

    2016-02-02

    Monolith-based in-tube solid phase microextraction (MB/IT-SPME) has received wide attention because of miniaturization, automation, expected loading capacity, and environmental friendliness. However, the unsatisfactory extraction efficiency becomes the main disadvantage of MB/IT-SPME. To overcome this circumstance, magnetism-enhanced MB/IT-SPME (ME-MB/IT-SPME) was developed in the present work, taking advantage of magnetic microfluidic principles. First, modified Fe3O4 nanoparticles were mixed with polymerization solution and in situ polymerized in the capillary to obtain a magnetic monolith extraction phase. After that, the monolithic capillary column was placed inside a magnetic coil that allowed the exertion of a variable magnetic field. The effects of intensity of magnetic field, adsorption and desorption flow rate, volume of sample, and desorption solvent on the performance of ME-MB/IT-SPME were investigated in detail. The analysis of six steroid hormones in water samples by the combination of ME-MB/IT-SPME with high-performance liquid chromatography with diode array detection was selected as a paradigm for the practical evaluation of ME-MB/IT-SPME. The application of a controlled magnetic field resulted in an obvious increase of extraction efficiencies of the target analytes between 70% and 100%. The present work demonstrated that application of different magnetic forces in adsorption and desorption steps can effectively enhance extraction efficiency of MB/IT-SPME systems.

  14. Liquid chromatographic determination of quinolones in water and human urine samples after microextraction by packed sorbent.

    Science.gov (United States)

    Rani, Susheela; Kumar, Ashwini; Malik, Ashok Kumar; Singh, Baldev

    2012-01-01

    A method for the simultaneous determination of quinolones in water and urine samples by microextraction in a sorbent-packed syringe (MEPS) with LC is described. MEPS is a new miniaturized SPE technique that can be used with chromatographic instruments without any modifications. In MEPS, approximately 1 mg of the solid packing material is inserted into a syringe (100-250 microL) as a plug. Sample preparation takes place on the packed bed. The new method is promising, easy to use, economical, and rapid. The determination of quinolones in groundwater and urine was performed using MEPS as a sample preparation method with LC-UV determination. Four quinolone antibiotics--enrofloxacin, enoxacin, danofloxacin, and nalidixic acid--in groundwater and urine samples were used as analytes. The extraction recovery was found to be between 64.9 and 98.9%. The results showed high correlation coefficients (R2 > 0.992) for all of the analytes within the calibration range. The LOQ was between 0.091 and 0.315 ng/mL.

  15. Analysis of quinolones by voltage-assisted liquid-phase microextraction combined with LC-MS.

    Science.gov (United States)

    Wang, Mi-Hung; Wang, Shu-Ping

    2012-03-01

    The method of liquid-phase microextraction assisted with voltage was developed and applied on determination of quinolones in water sample in this study. Both of the reproducibility and extraction time were improved with the aid of applying voltage. Four analytes in neutral state such as cinoxacin, oxolinic acid, nalidixic acid, and flumequine were extracted from a sample solution at pH 2.0, through a polypropylene hollow fiber which was immobilized with 2-octanone, and then into a 25 μL of the acceptor phase of 40 mM borate buffer at pH 10.0 by applying voltage of 100 V. Subsequently, the acceptor solution was directly subjected to analysis by LC-MS. The performance of the method for four quinolones was also evaluated. Linearity was obtained in the range of 1.0-25.0 ng/mL with R(2) > 0.996. Limits of detection were below 0.6 ng/mL, and recoveries of water sample were ranged from 90.8 to 109.6%.

  16. Ordered mesoporous carbon/Nafion as a versatile and selective solid-phase microextraction coating.

    Science.gov (United States)

    Zeng, Jingbin; Zhao, Cuiying; Chen, Jingjing; Subhan, Fazle; Luo, Liwen; Yu, Jianfeng; Cui, Bingwen; Xing, Wei; Chen, Xi; Yan, Zifeng

    2014-10-24

    In this study, ordered mesoporous carbon (OMC) with large surface area (1019m(2)g(-1)), uniform mesoporous structure (pore size distribution centering at 4.2nm) and large pore volume (1.46cm(3)g(-1)) was synthesized using 2D hexagonally mesoporous silica MSU-H as the hard template and sucrose as the carbon precursor. The as-synthesized OMC was immobilized onto a stainless steel wire using Nafion as a binder to prepare an OMC/Nafion solid-phase microextraction (SPME) coating. The extraction characteristics of the OMC/Nafion coating were extensively investigated using a wide range of analytes including non-polar (light petroleum and benzene homologues) and polar compounds (amines and phenols). The OMC/Nafion coating exhibited much better extraction efficiency towards all selected analytes than that of a multi-walled carbon nanotubes/Nafion coating with similar length and thickness, which is ascribed to its high surface area, well-ordered mesoporous structure and large pore volume. When the OMC/Nafion coating was used to extract a mixture containing various kinds of analytes, it possessed excellent extraction selectivity towards aromatic non-polar compounds. In addition, the feasibility of the OMC/Nafion coating for application in electrochemically enhanced SPME was demonstrated using protonated amines as model analytes. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Improved detection limits for phthalates by selective solid-phase micro-extraction

    KAUST Repository

    Zia, Asif I.

    2016-03-30

    Presented research reports on an improved method and enhanced limits of detection for phthalates; a hazardous additive used in the production of plastics by solid-phase micro-extraction (SPME) polymer in comparison to molecularly imprinted solid-phase extraction (MISPE) polymer. The polymers were functionalized on an interdigital capacitive sensor for selective binding of phthalate molecules from a complex mixture of chemicals. Both polymers owned predetermined selectivity by formation of valuable molecular recognition sites for Bis (2-ethylhexyl) phthalate (DEHP). Polymers were immobilized on planar electrochemical sensor fabricated on a single crystal silicon substrate with 500 nm sputtered gold electrodes fabricated using MEMS fabrication techniques. Impedance spectra were obtained using electrochemical impedance spectroscopy (EIS) to determine sample conductance for evaluation of phthalate concentration in the spiked sample solutions with various phthalate concentrations. Experimental results revealed that the ability of SPME polymer to adsorb target molecules on the sensing surface is better than that of MISPE polymer for phthalates in the sensing system. Testing the extracted samples using high performance liquid chromatography with photodiode array detectors validated the results.

  18. HPLC assay of tomato carotenoids: validation of a rapid microextraction technique.

    Science.gov (United States)

    Sérino, Sylvie; Gomez, Laurent; Costagliola, Guy; Gautier, Hélène

    2009-10-14

    Carotenoids are studied for their role as pigments and as precursors of aromas, vitamin A, abscisic acid, and antioxidant compounds in different plant tissues. A novel, rapid, and inexpensive analytical protocol is proposed to enable the simultaneous analysis of four major tomato carotenoids: lutein, lycopene, beta-carotene, and phytoene. Microextraction is performed in the presence of sodium chloride, n-hexane, dichloromethane, and ethyl acetate on fresh tomato powder that has been finely ground in liquid nitrogen. The carotenoids are extracted by agitation and centrifugation and then analyzed by HPLC using a diode array detector. The principal advantage of this extraction resides in the absence of an evaporation step, often necessary to assay tomato carotenoids other than lycopene. Whatever the carotenoid, tests for accuracy, reproducibility, and linearity were satisfactory and indicative of the method's reliability. The stability of extracts over time (several days at -20 degrees C) as the satisfactory sensitivity of the assay whatever the fruit ripeness had a part in the robustness of the method. Reliable, rapid, simple, and inexpensive, this extraction technique is appropriate for the routine analysis of carotenoids in small samples.

  19. Knitting aromatic polymers for efficient solid-phase microextraction of trace organic pollutants.

    Science.gov (United States)

    Liu, Shuqin; Hu, Qingkun; Zheng, Juan; Xie, Lijun; Wei, Songbo; Jiang, Ruifen; Zhu, Fang; Liu, Yuan; Ouyang, Gangfeng

    2016-06-10

    A series of knitting aromatic polymers (KAPs) were successfully synthesized using a simple one-step Friedel-Crafts alkylation of aromatic monomers and were characterized by transmission electron microscopy (TEM), Fourier transform infrared (FTIR) spectroscopy, and X-ray photoelectron spectroscopy (XPS). Then, as-synthesized KAPs with large surface areas, unique pore structures and high thermal stability were prepared as solid-phase microextraction (SPME) coatings that exhibited good extraction abilities for a series of benzene compounds (i.e., benzene, toluene, ethylbenzene and m-xylene, which are referred to as BTEX) and polycyclic aromatic hydrocarbons (PAHs). Under the optimized conditions, the methodologies established for the determination of BTEX and PAHs using the KAPs-triPB and KAPs-B coatings, respectively, possessed wide linear ranges, low limits of detection (LODs, 0.10-1.13ngL(-1) for BTEX and 0.05-0.49ngL(-1) for PAHs) and good reproducibility. Finally, the proposed methods were successfully applied to the determination of BTEX and PAHs in environmental water samples, and satisfactory recoveries (93.6-124.2% for BTEX and 77.2-113.3% for PAHs) were achieved. This study provides a benchmark for exploiting novel microporous organic polymers (MOPs) for SPME applications.

  20. Carbonized polydopamine as coating for solid-phase microextraction of organochlorine pesticides.

    Science.gov (United States)

    Huang, Zhenzhen; Chua, Pey Ee; Lee, Hian Kee

    2015-06-19

    A facile preparation route for coating a stainless steel fiber with carbonaceous material derived from polydopamine is reported in this work. The self-oxidation induced polymerization of dopamine in alkaline solution enables growth of polydopamine on the inert surface of the fiber. The robust adhesion of dopamine to metal oxides ensured sufficient stability of the polymer coating. After carbonization of the polymer coating, the obtained carbon coated fiber was utilized for solid-phase microextraction and exhibited effectiveness in the extraction of organochlorine pesticides (OCPs) from aqueous solution. Extraction time, agitation speed and salt addition were optimized. The possible interference of humic acid on the extraction of these analytes was also investigated. The results showed that most of the analytes could be detected efficiently in the presence of humic acid at a concentration of 20mg/L. Under the optimized conditions, enrichment factors of 102-757 were obtained for the selected OCPs in aqueous solution. The proposed method provided low limits of detection (1.4-15 ng/L), good linearity (correlation coefficients>0.9971) and acceptable precision (relative standard deviations<16.3%). Copyright © 2015 Elsevier B.V. All rights reserved.