Sample records for liquid scintillation validation

  1. Validation the quantification of beta emitters activity in urine by scintillation spectrometry in the liquid phase

    International Nuclear Information System (INIS)

    Sierra, I.; Hernandez, C.; Benito, P.; Lopez, C.

    2013-01-01

    In this paper the methodology used in the validation of the technique for quantifying activity of some beta emitters in urine ( 3 H, 1 4C, 3 5S, 3 2P and 9 0Sr) by scintillation spectrometry Liquid Phase (Liquid Scintillation Counting, LSC) is described in bio elimination Laboratory Service CIEMAT Radiation Dosimetry accredited since last year for carrying out assays measure radiation dose based on ISO forth above. (Author)

  2. Liquid scintillation solutions

    International Nuclear Information System (INIS)

    Long, E.C.

    1976-01-01

    The liquid scintillation solution described includes a mixture of: a liquid scintillation solvent, a primary scintillation solute, a secondary scintillation solute, a variety of appreciably different surfactants, and a dissolving and transparency agent. The dissolving and transparency agent is tetrahydrofuran, a cyclic ether. The scintillation solvent is toluene. The primary scintillation solute is PPO, and the secondary scintillation solute is dimethyl POPOP. The variety of appreciably different surfactants is composed of isooctylphenol-polyethoxyethanol and sodium dihexyl sulphosuccinate [fr

  3. Liquid scintillation solution

    International Nuclear Information System (INIS)

    Long, E.C.

    1977-01-01

    A liquid scintillation solution is described which includes (1) a scintillation solvent (toluene and xylene), (2) a primary scintillation solute (PPO and Butyl PBD), (3) a secondary scintillation solute (POPOP and Dimethyl POPOP), (4) a plurality of substantially different surfactants and (5) a filter dissolving and/or transparentizing agent. 8 claims

  4. Liquid scintillation measurement. I

    International Nuclear Information System (INIS)

    Rexa, R.; Tykva, R.

    1983-01-01

    The individual components of scintillation solutions and their tasks are listed. Explained briefly is the scintillation process in a liquid scintillator. Factors are discussed which influence this process as are methods applied to supress their influence. They include: ionization quenching, quenching by dilution and concentration, chemical, colour, phase and photon quenching and single-photon events causing an undesirable backgorund. (M.D.)

  5. Liquid scintillation solution

    International Nuclear Information System (INIS)

    Long, E.C.

    1976-01-01

    The invention deals with a liquid scintillation solution which contains 1) a scintillation solvent (toluol), 2) a primary scintillation solute (PPO), 3) a secondary scintillation solute (dimethyl POPOP), 4) several surfactants (iso-octyl-phenol polyethoxy-ethanol and sodium di-hexyl sulfosuccinate) essentially different from one another and 5) a filter resolution and/or transparent-making agent (cyclic ether, especially tetrahydrofuran). (HP) [de

  6. Method validation for simultaneous counting of Total α , β in Drinking Water using Liquid Scintillation Counter

    International Nuclear Information System (INIS)

    Al-Masri, M. S.; Nashawati, A.

    2014-05-01

    In this work, Method Validation Methods and Pulse Shape Analysis were validated to determine gross Alpha and Beta Emitters in Drinking Water using Liquid Scintillation Counter Win spectral 1414. Validation parameters include Method Detection Limit, Method Quantitation Limit, Repeatability Limit, Intermediate Precision, Trueness) Bias), Recovery Coefficient, Linearity and Uncertainty Budget in analysis. The results show that the Method Detection Limit and Method Quantitation Limit were 0.07, 0.24 Bq/l for Alpha emitters respectively, and 0.42, 1.4 Bq/l for Beta emitters, respectively. The relative standard deviation of Repeatability Limit reached 2.81% for Alpha emitters and 3.96% for Beta emitters. In addition to, the relative standard deviation of Intermediate Precisionis was 0.54% for Alpha emitters and 1.17% for Beta emitters. Moreover, the trueness was - 7.7% for Alpha emitters and - 4.5% for Beta emitters. Recovery Coefficient ranged between 87 - 96% and 88-101 for Alpha and Beta emitters, respectively. Linearity reached 1 for both Alpha and Beta emitters. on the other hand, Uncertainty Budget for all continents was 96.65% ,83.14% for Alpha and Beta emitters, respectively (author).

  7. Inorganic liquid scintillator

    International Nuclear Information System (INIS)

    Pavlicek, Z.; Barta, C.; Jursova, L.

    1986-01-01

    An inorganic liquid scintillator is designed which contains 1 to 30 wt.% of an inorganic molecular compound as the basic active component; the compound contains a cation with an atomic number higher than 47 and a halogen anion. The basic inorganic component is dissolved in water or in an organic solvent in form of non-dissociated molecules or self-complexes in which the bond is preserved between the cation and anion components. The light yield from these scintillators ranges between 70 and 150% of the light yield of a standard organic scintillator based on toluene. They are advantageous in that that they allow to increase the water content in the sample to up to 100%. (M.D.)

  8. Liquid scintillation, counting, and compositions

    International Nuclear Information System (INIS)

    Sena, E.A.; Tolbert, B.M.; Sutula, C.L.

    1975-01-01

    The emissions of radioactive isotopes in both aqueous and organic samples can be measured by liquid scintillation counting in micellar systems. The micellar systems are made up of scintillation solvent, scintillation solute and a mixture of surfactants, preferably at least one of which is relatively oil-soluble water-insoluble and another which is relatively water-soluble oil-insoluble

  9. Neutron crosstalk between liquid scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Verbeke, J.M., E-mail: verbeke2@llnl.gov; Prasad, M.K., E-mail: prasad1@llnl.gov; Snyderman, N.J., E-mail: snyderman1@llnl.gov

    2015-09-11

    A method is proposed to quantify the fractions of neutrons scattering between liquid scintillators. Using a spontaneous fission source, this method can be utilized to quickly characterize an array of liquid scintillators in terms of crosstalk. The point model theory due to Feynman is corrected to account for these multiple scatterings. Using spectral information measured by the liquid scintillators, fractions of multiple scattering can be estimated, and mass reconstruction of fissile materials under investigation can be improved. Monte Carlo simulations of mono-energetic neutron sources were performed to estimate neutron crosstalk. A californium source in an array of liquid scintillators was modeled to illustrate the improvement of the mass reconstruction.

  10. Neutron crosstalk between liquid scintillators

    International Nuclear Information System (INIS)

    Verbeke, J.M.; Prasad, M.K.; Snyderman, N.J.

    2015-01-01

    A method is proposed to quantify the fractions of neutrons scattering between liquid scintillators. Using a spontaneous fission source, this method can be utilized to quickly characterize an array of liquid scintillators in terms of crosstalk. The point model theory due to Feynman is corrected to account for these multiple scatterings. Using spectral information measured by the liquid scintillators, fractions of multiple scattering can be estimated, and mass reconstruction of fissile materials under investigation can be improved. Monte Carlo simulations of mono-energetic neutron sources were performed to estimate neutron crosstalk. A californium source in an array of liquid scintillators was modeled to illustrate the improvement of the mass reconstruction

  11. Liquid scintillation in medical diagnosis

    International Nuclear Information System (INIS)

    Painter, K.

    1976-01-01

    With the tremendous increase in the application of radioassay, particularly radioimmunoassay, in the clinical laboratory liquid scintillation counting became an indispensable tool in diagnostic medicine. Few publications, however, have concerned themselves with problem areas which occur with the method in the clinical laboratory. The purpose of this presentation is to summarize our experiences with the liquid scintillation technique in the clinical situation

  12. Liquid scintillation counting of chlorophyll

    International Nuclear Information System (INIS)

    Fric, F.; Horickova, B.; Haspel-Horvatovic, E.

    1975-01-01

    A precise and reproducible method of liquid scintillation counting was worked out for measuring the radioactivity of 14 C-labelled chlorophyll a and chlorophyll b solutions without previous bleaching. The spurious count rate caused by luminescence of the scintillant-chlorophyll system is eliminated by using a suitable scintillant and by measuring the radioactivity at 4 to 8 0 C after an appropriate time of dark adaptation. Bleaching of the chlorophyll solutions is necessary only for measuring of very low radioactivity. (author)

  13. Scintillating properties of frozen new liquid scintillators

    CERN Document Server

    Britvich, G I; Golovkin, S V; Martellotti, G; Medvedkov, A M; Penso, G; Soloviev, A S; Vasilchenko, V G

    1999-01-01

    The light emission from scintillators which are liquid at room temperature was studied in the interval between $+20$~$^{\\circ}$C and $-120$~$^{\\circ}$C, where the phase transition from liquid to solid takes place. The light yield measured at $-120$~$^{\\circ}$C is about twice as much as that observed at $+20$~$^{\\circ}$C. By cooling the scintillator from $+20$~$^{\\circ}$C to $-120$~$^{\\circ}$C and then heating it from $-120$~$^{\\circ}$C to $+20$~$^{\\circ}$C, the light yield varies in steps at well defined temperatures, which are different for the cooling and heating processes. These hysteresis phenomena appear to be related to the solvent rather than to the dopant. The decay time of scintillation light was measured at $+20$~$^{\\circ}$C and $-120$~$^{\\circ}$C. Whilst at room temperature most of the light is emitted with a decay time of 6--8 ns, at $-120$~$^{\\circ}$C a slower component, with a decay time of 25--35 ns, becomes important.

  14. Applications of liquid scintillation tubes

    International Nuclear Information System (INIS)

    Broga, D.W.

    1977-01-01

    A new cocktail containing device for liquid scintillation counting, the scintillation tube, consists of a two-layered plastic bag which is heatsealed after the cocktail and sample have been placed in it. It is then placed in a carrying vial and counted in a conventional liquid scintillation counter. These tubes have proved to be a practical and economical alternative to vials. Some of their advantages are elimination of absorption problems, transparency, lower background and higher counting efficiency, low breakage danger and savings in waste disposal costs. Two applications for which the tubes are particularly suitable are the counting of laboratory swipes and urine analysis. (author)

  15. Radiation damage studies on new liquid scintillators and liquid-core scintillating fibers

    International Nuclear Information System (INIS)

    Golovkin, S.V.

    1994-01-01

    The radiation resistant of some new liquid scintillation and capillaries filled with liquid scintillators has been presented. It was found that scintillation efficiency of the scintillator based on 1-methyl naphthalene with a new R39 only by 10% at the dose of 190 Mrad and the radiation resistance of thin liquid-core scintillating was decreased fibers exceeded 60 Mrad. 35 refs

  16. Nanophosphor composite scintillator with a liquid matrix

    Science.gov (United States)

    McKigney, Edward Allen; Burrell, Anthony Keiran; Bennett, Bryan L.; Cooke, David Wayne; Ott, Kevin Curtis; Bacrania, Minesh Kantilal; Del Sesto, Rico Emilio; Gilbertson, Robert David; Muenchausen, Ross Edward; McCleskey, Thomas Mark

    2010-03-16

    An improved nanophosphor scintillator liquid comprises nanophosphor particles in a liquid matrix. The nanophosphor particles are optionally surface modified with an organic ligand. The surface modified nanophosphor particle is essentially surface charge neutral, thereby preventing agglomeration of the nanophosphor particles during dispersion in a liquid scintillator matrix. The improved nanophosphor scintillator liquid may be used in any conventional liquid scintillator application, including in a radiation detector.

  17. Time resolution research in liquid scintillating detection

    International Nuclear Information System (INIS)

    He Hongkun; Shi Haoshan

    2006-01-01

    The signal processing design method is introduced into liquid scintillating detection system design. By analyzing the signal of liquid scintillating detection, improving time resolution is propitious to upgrade efficiency of detecting. The scheme of realization and satisfactory experiment data is demonstrated. Besides other types of liquid scintillating detection is the same, just using more high speed data signal processing techniques and elements. (authors)

  18. Validation of Analysis Method of pesticides in fresh tomatoes by Gas Chromatography associated to a liquid scintillation counting

    International Nuclear Information System (INIS)

    Dhib, Ahlem

    2011-01-01

    Pesticides are nowadays considered as toxic for human health. The maximum residues levels (MRL) in foodstuff are more and more strict. Therefore, selective analytical techniques are necessary for their identification and their quantification. The aim of this study is to set up a multi residue method for the determination of pesticides in tomatoes by gas chromatography with μECD detector (GC/μECD) associated to liquid scintillation counting. A global analytical protocol consisting of a QuECHERS version of the extraction step followed by purification step of the resulting extract on a polymeric sorbent was set up. The 14 C-chloropyrifos used as an internal standard proved excellent to control the different steps needed for the sample preparation. The method optimized is specific, selective with a recovery averaged more than 70 pour cent, repetitive and reproducible. Although some others criteria need to be checked regarding validation before its use in routine analysis, the potential of the method has been demonstrated.

  19. Liquid scintillation alpha spectrometry techniques

    International Nuclear Information System (INIS)

    McKlveen, J.W.; McDowell, W.J.

    1984-01-01

    Accurate, quantitative determinations of alpha emitting nuclides by conventional plate counting methods are difficult, because of sample self-absorption problems in counting and because of non-reproducible losses in conventional sample separation methods. Liquid scintillation alpha spectrometry offers an attractive alternative with no sample self-absorption or geometry problems and with 100% counting efficiency. Sample preparation may include extraction of the alpha emitter of interest by a specific organic phase-soluble compound directly into the liquid scintillation counting medium. Detection electronics use energy and pulse-shape discrimination, to yield alpha spectra without beta and gamma background interference. Specific procedures have been developed for gross alpha, uranium, plutonium, thorium and colonium assay. Possibilities for a large number of other applications exist. Accuracy and reproducibility are typically in the 1% range. Backgrounds of the order of 0.01 cpm are readily achievable. The paper will present an overview of liquid scintillation alpha counting techniques and some of the results achieved for specific applications. (orig.)

  20. Validation the quantification of beta emitters activity in urine by scintillation spectrometry in the liquid phase; Validacion de la cuantificacion de actividad de emisores beta en orina mediante espectrometria de centelleo en fase liquida

    Energy Technology Data Exchange (ETDEWEB)

    Sierra, I.; Hernandez, C.; Benito, P.; Lopez, C.

    2013-07-01

    In this paper the methodology used in the validation of the technique for quantifying activity of some beta emitters in urine ({sup 3}H, {sup 1}4C, {sup 3}5S, {sup 3}2P and {sup 9}0Sr) by scintillation spectrometry Liquid Phase (Liquid Scintillation Counting, LSC) is described in bio elimination Laboratory Service CIEMAT Radiation Dosimetry accredited since last year for carrying out assays measure radiation dose based on ISO forth above. (Author)

  1. Liquid mixtures for scintillation counters

    International Nuclear Information System (INIS)

    Kauffmann, J.M.

    1975-01-01

    Liquid scintillators contain emulsifiers or combinations of these which can be used over a wide temperature range for a multitude of aqueous samples. These emulsifiers are block-polymerides with a nonhygroscopic center part of the chain of oxypropylene combinations recieved by addition of propylene oxide to both hydroxyl groups of a propylene-glycol nucleus and both ends of the center part of the chain terminating in hygroscopic poly(oxyethylene) groups. The length of the nonhygroscopic center part of the chain varies from about 800 to 3,000 or 4,000 in molecular weight. The hygroscopic poly(oxyethylene) end groups have a controlled length constituting about 10 to 80wt.% of the finished molecule. The most useful members of this group of co-polymerides possess a length of their poly(oxypropylene) chains corresponding to a value of y of about 15 to 56 and a length of their poly(oxyethylene)chains corresponding to values of x and z between 1 and 35 . All known fluorines can be used. With the scintillators the radioimmunoassay can also be carried through. (DG/PB) [de

  2. Liquid scintillator mixable with water

    International Nuclear Information System (INIS)

    Benson, R.H.

    1976-01-01

    A liquid scintillator mixable with water is described consisting of an aromatic solvent (xylene), a scintillation material and an ethoxylated alkyl phenol (as surface-active substance). So far such kinds of system have not given good measurements on counting samples with high water content. Due to the invention's composition one gets good results even with counting samples having a water content of over 30% if the alkyl substituent of the alkyl phenol contains 7, 10, 11, 13, 14, 15 or 16 C atoms and the ratio n/x of the number n of C atoms of the alkyl substituents to the average number x of the ethoxy groups of the ethoxylated alkyl phenols lie between 0.83 and 1.67. The following alkyl phenols are mentioned: heptyl phenol (n/x between 0.83 and 1.08), decyl phenol (n/x between 0.90 and 1.17), hendecyl phenol (n/x between 0.93 and 1.22), tridecyl phenol (n/x between 0.97 and 1.34), tetradecyl phenol (n/x between 1.08 and 1.55), pentadecyl phenol (n/x between 1.15 and 1.67), hexadecyl phenol (n/x between 1.33 and 1.51). (UWI) [de

  3. Development of a reference liquid scintillation cocktail

    CSIR Research Space (South Africa)

    Van Wyn Gaardt, WM

    2006-02-01

    Full Text Available A reference system that would allow national laboratories to compare their activity measurements of non-gamma-emitting radionuclides at any time is currently being developed. The system requires a non-commercial reference-liquid scintillation...

  4. Method validation and verification in liquid scintillation counting using the long-term uncertainty method (LTUM) on two decades of proficiency test data

    International Nuclear Information System (INIS)

    Verrezen, F.; Vasile, M.; Loots, H.; Bruggeman, M.

    2017-01-01

    Results from proficiency tests gathered over the past two decades by the laboratory for low level radioactivity measurements for liquid scintillation counting of 3 H (184 results) and 14 C (74 results) are used to verify the validated measurement methods used by the laboratory, in particular the estimated uncertainty budget of the method and its reproducibility and stability. A linear regression approach is used for the analysis of the results, described in the literature as the long term uncertainty in measurement method. The present study clearly indicates the advantages of using proficiency test results in identifying possible constant or proportional bias effects as well as the possibility to compare the laboratory performance with the performance of peer laboratories. (author)

  5. Liquid scintillation spectrometer survey 155Eu liquid activity

    International Nuclear Information System (INIS)

    Zhang Zuhua

    2002-01-01

    In the countrywide contrasting survey of 155 Eu activity, 155 Eu liquid activity was determined for the first time through using liquid scintillation spectrometer survey 155 Eu β ray. In survey total uncertainty, determining activity accord with determining activity average value of all a wide variety of survey instrument entering into contrasting survey. But using liquid scintillation spectrometer survey, it is simple and save time, is beyond compare for other survey method. It indicate liquid scintillation spectrometer survey β-γ nuclide activity is effective as well

  6. Validation of a an analysis method of Marine Bio toxins Type Saxitoxin based on test coupled receptor (RBA) with Radiochemical Detection with liquid scintillation

    International Nuclear Information System (INIS)

    Selmi, Zied

    2009-01-01

    The saxitoxin s are bio toxins belonging to the family of toxins of the type PSP. They are paralysing toxins secreted by marine micro-organisms, phytoplankton, called Alexandrium. They constitute a risk for the human health in the event of their consumption in contaminated food. The acceptable maximum limit of these bio toxins in molluscs and shellfish is fixed to 800 μg /kg of meat of molluscs or shellfish. It proves, thus, that it is essential to develop and validate analytical methods for the level monitoring of contamination of the marine resources by these species in order to found a program of their monitoring and to guarantee an acceptable level of the food safety of the products available on the national and international markets. The present work allowed the validation of the quantification method of these toxins which is based on the use of the Receptor Binding Assay (RBA) with liquid scintillation nuclear technique detection using tritium as radiotracer and while proceeding by the different statistical tests of validation (Standard Nf XP T 90-210). The field of linearity ranged from 0 to 20 n M and the limit of detection was found to be 1 n M. The validation of this method will allow the reinforcement of the analytical means of analysis of marine bi toxins type SXT and to set up, in the near future, a monitoring and surveillance routine program for these bio toxins at the national, regional and African scales. (Author)

  7. (Alpha-) quenching temperature dependence in liquid scintillator

    Energy Technology Data Exchange (ETDEWEB)

    Soerensen, Arnd; Lozza, Valentina; Krosigk, Belina von; Zuber, Kai [Institut fuer Kern- und Teilchenphysik, TU Dresden (Germany)

    2015-07-01

    Liquid scintillator (LS) is an effective and promising detector material, which is and will be used by many small and large scale experiments. In order to perform correct signal identification and background suppression, a very good knowledge of LS properties is crucial. One of those is the light yield from alpha particles in liquid scintillator. This light output strongly quenched, approx. 10 times compared to that of electrons, and has been precisely studied at room temperature for various LS. Big scintillator experiments, such as SNO+ and maybe future large scale detectors, will operate at different temperatures. While a strong temperature dependence is well known for solid state scintillators, due to the different scintillation process, a quenching temperature dependence in LS is usually assumed negligible. On the other hand, inconsistencies in between measurements are often explained by potential temperature effects. This study investigates LAB based liquid scintillator with an intrinsic, dissolved alpha emitter and its behaviour with temperature change. In a small, cooled and heated setup, a stabilized read-out with two PMTs is realised. First results are presented.

  8. Radiocarbon dating methods using benzene liquid scintillation

    International Nuclear Information System (INIS)

    Togashi, Shigeko; Matsumoto, Eiji

    1983-01-01

    The radiocarbon dating method using benzene liquid scintillation is reported in detail. The results of measurement of NBS oxalic acid agree with the recommended value, indicating that isotopic fractionation during benzene synthesis can be negligible. Ten samples which have been already measured by gas counter are dated by benzene liquid scintillation. There is no significant difference in age for the same sample between benzene liquid scintillation and gas counters. It is shown that quenching has to be corrected for the young sample. Memory effect in stainless steel reaction vessel can be removed by using an exchangeable inner vessel and by baking it in the air. Using this method, the oldest age that can be measured with 2.3 g carbon is 40,000 years B.P. (author)

  9. Radioactivity measurements by liquid scintillation spectroscopy

    International Nuclear Information System (INIS)

    Cassette, Ph.

    2004-01-01

    The activity measurement techniques by liquid scintillation spectroscopy consist to mix the radioactive solution to measure with a scintillating liquid and to transform the ionizing radiations, resulting from decays, into light, detectable and quantifiable. The main advantages of these techniques are the easiness of preparation of the radioactive sources, the geometric efficiency of detection of 4π and the possibility of detection of low-level energy radiations. There are one of the only methods giving the possibility to measure the activity of pure β radionuclides; indeed, the nuclear disintegration is not accompanied of gamma radiations detectable by other techniques. There are one of the only methods too of measurement of radionuclides which disintegrate by electron capture and especially those leading to the emission of low-level energy ionizing radiations. Liquid scintillation spectroscopy can be used as an absolute method of activity measurement that is to say without the use of a calibration standard. The modern liquid scintillation counting devices can be very sensitive; the measurement of micro-activities being possible. Some of the applications of these activity measurement techniques are the carbon 14 dating and the geological tracing. Their main disadvantage is the global energetic yield which is low and variable in terms of the composition of the scintillation source necessitating to calculate the detection yield for each condition of measurement. (O.M.)

  10. Applications of low level liquid scintillation counting

    International Nuclear Information System (INIS)

    Noakes, J.E.

    1983-01-01

    Low level liquid scintillation counting is reviewed in terms of its present use and capabilities for measuring low activity samples. New areas of application of the method are discussed with special interest directed to the food industry and environmental monitoring. Advantages offered in the use of a low background liquid scintillation counter for the nuclear power industry and nuclear navy are discussed. Attention is drawn to the need for commercial development of such instrumentation to enable wider use of the method. A user clientele is suggested as is the required technology to create such a counter

  11. System and method of liquid scintillation counting

    International Nuclear Information System (INIS)

    Rapkin, E.

    1977-01-01

    A method of liquid scintillation counting utilizing a combustion step to overcome quenching effects comprises novel features of automatic sequential introduction of samples into a combustion zone and automatic sequential collection and delivery of combustion products into a counting zone. 37 claims, 13 figures

  12. Neutron spectrometer using NE218 liquid scintillator

    International Nuclear Information System (INIS)

    Dance, J.B.; Francois, P.E.

    1976-01-01

    A neutron spectrometer has been constructed using NE218 liquid scintillator. Discrimination against electron-gamma events was obtained usng a charge-comparison pulse shape discrimination system. The resolution obtained was about 0.25 MeV F.W.H.M. at 2.0 MeV

  13. Liquid scintillation counting (LSC) - an overview

    International Nuclear Information System (INIS)

    Ravi, S.; Mathew, K.M.

    2005-01-01

    In Liquid Scintillation Counting, the amount of light produced is proportional to the amount of radiation present in the sample and the energy of the light produced is proportional to the energy of the radiation that is present in the sample. This makes LSC a very convenient tool to measure radioactivity

  14. Determining random counts in liquid scintillation counting

    International Nuclear Information System (INIS)

    Horrocks, D.L.

    1979-01-01

    During measurements involving coincidence counting techniques, errors can arise due to the detection of chance or random coincidences in the multiple detectors used. A method and the electronic circuits necessary are here described for eliminating this source of error in liquid scintillation detectors used in coincidence counting. (UK)

  15. Sample oxidation for liquid scintillation counting

    International Nuclear Information System (INIS)

    Kisieleski, W.E.; Buess, E.M.

    1976-01-01

    The general features of biological and medical investigations which are responsible for the demands such investigations place upon the design specifications of liquid scintillation counters and associated methodology are reviewed. Special emphasis is given to the oxidative technique for sample preparation

  16. Development of new Polysiloxane Based Liquid Scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Dalla Palma, M.; Quaranta, A. [Department of Industrial Engineering, University of Trento,Via Sommarive, 9, 38123 Trento (Italy); INFN, Laboratori Nazionali di Legnaro,Viale dell' Universita, 2, 35020 Legnaro - Padova (Italy); Gramegna, F.; Marchi, T.; Cinausero, M. [INFN, Laboratori Nazionali di Legnaro,Viale dell' Universita, 2, 35020 Legnaro - Padova (Italy); Carturan, S.; Collazuol, G.; Checchia, C. [INFN, Laboratori Nazionali di Legnaro,Viale dell' Universita, 2, 35020 Legnaro - Padova (Italy); Department of Physics and Astronomy, University of Padova, Via Marzolo, 8, 35131 Padova (Italy); Degerlier, M. [Department of Physics, Nevsehir Haci Bektas Veli University, Science and Art Faculty, 50300 Nevsehir (Turkey)

    2015-07-01

    In the last decade, attention toward neutron detection has been growing in the scientific community, driven by new requirements in different fields of application ranging from homeland security to medical and material analysis, from research physics, to nuclear energy production. So far neutron detection, with particular attention to fast neutrons, has been mainly based on organic liquid scintillators, owing to their good efficiency and pulse shape discrimination (PSD) capability. Most of these liquids have however some main drawbacks given by toxicity, flammability, volatility and sensitivity to dissolved oxygen that limits the duration and the quality of their performances with worse handiness and increased costs. Phenyl-substituted polysiloxanes could address most of these issues, being characterized by low toxicity, low volatility and low flammability. Their optical properties can be tailored by changing the phenyl distribution and concentration thus allowing to increase the solubility of organic dyes, to modify the fluorescence spectra and to vary the refractive index of the medium. Furthermore, polysiloxanes have been recently exploited for the production of plastic scintillators with very good chemical and thermal stability and very good radiation hardness and the development of polysiloxane liquid scintillators could allow to combine these interesting properties with the supremacy of liquid scintillators as regarding PSD over plastics. For these reasons, the properties of several phenyl-substituted polysiloxane with different phenyl amounts and different viscosities have been investigated, with particular attention to the scintillation response and the pulse shape discrimination capability, and the results of the investigation are reported in this work. More in details, the scintillation light yield towards gamma rays ({sup 60}Co and {sup 137}Cs) of several polysiloxane liquids has been analyzed and compared with the light yield of a commercial non

  17. Liquid scintillation counting system with automatic gain correction

    International Nuclear Information System (INIS)

    Frank, R.B.

    1976-01-01

    An automatic liquid scintillation counting apparatus is described including a scintillating medium in the elevator ram of the sample changing apparatus. An appropriate source of radiation, which may be the external source for standardizing samples, produces reference scintillations in the scintillating medium which may be used for correction of the gain of the counting system

  18. Near-infrared scintillation of liquid argon

    Energy Technology Data Exchange (ETDEWEB)

    Alexander, T. [Fermilab; Escobar, C. O. [Campinas State U.; Lippincott, W. H. [Fermilab; Rubinov, P. [Fermilab

    2016-03-03

    Since the 1970s it has been known that noble gases scintillate in the near infrared (NIR) region of the spectrum (0.7 $\\mu$m < $\\lambda$; < 1.5$\\mu$m). More controversial has been the question of the NIR light yield for condensed noble gases. We first present the motivation for using the NIR scintillation in liquid argon detectors, then briefly review early as well as more recent efforts and finally show encouraging preliminary results of a test performed at Fermilab.

  19. Survey on the presence of 90Sr in milk samples by a validated ultra low level liquid scintillation counting (LSC method

    Directory of Open Access Journals (Sweden)

    dell’Oro D.

    2013-04-01

    Full Text Available 90Sr is one of the most biologically hazardous radionuclides produced in nuclear fission processes and decays emitting high-energy beta particles turning 90Y. 90Sr is transferred from soil-plant to cow’s milk and then to humans if it is introduced into the environment. Radiostrontium is chemically similar to calcium entering the human body through several food chains and depositing in bone and blood-forming tissue (bone marrow. Among main foodstuffs assumed in human diet, milk is considered of special interest for radiostrontium determination, especially in emergency situations, because the consumption of contaminated milk is the main source of internal radiation exposure, particularly for infants. In this work an analytical method for the determination of radiostrontium in milk was developed and validated in order to determine low activity levels by liquid scintillation counting (LSC after achieving 90Y secular equilibrium condition. The analytical procedure was applied both in surveillance and routine programmes to detect radiocontamination in cow’s, goat and sheep milk samples.

  20. Beta emitter radionuclides (90Sr contamination in animal feed: validation and application of a radiochemical method by ultra low level liquid scintillation counting

    Directory of Open Access Journals (Sweden)

    Marco Iammarino

    2015-02-01

    Full Text Available 90Sr is considered as a dangerous contaminant of agri-food supply chains due to its chemical affinity with Calcium, which makes its absorption in bones easy. 90Sr accumulation in raw materials and then in final products is particularly significant in relationship to its ability to transfer into animal source products. The radionuclides transfer (137Cs and 90Sr from environment to forages and then to products of animal origin (milk, cow and pork meats was studied and evaluated in different studies, which were carried out in contaminated areas, from Chernobyl disaster until today. In the present work, the development and validation of a radiochemical method for the detection of 90Sr in different types of animal feed, and the application of this technique for routinely control activities, are presented. Liquid scintillation counting was the employed analytical technique, since it is able to determine very low activity concentrations of 90Sr (<0.01 Bq kg–1. All samples analysed showed a 90Sr contamination much higher than method detection limit (0.008 Bq kg–1. In particular, the highest mean activity concentration was registered in hay samples (2.93 Bq kg–1, followed by silage samples (2.07 Bq kg–1 and animal feeds (0.77 Bq kg–1. In fact, all samples were characterized by 90Sr activity concentrations much lower than reference limits. This notwithstanding, the necessity to monitor these levels was confirmed, especially considering that 90Sr is a possible carcinogen for human.

  1. Optics study of liquid scintillation counting systems

    International Nuclear Information System (INIS)

    Duran Ramiro, M. T.; Garcia-Torano, E.

    2005-01-01

    Optics is a key issue in the development of any liquid scintillation counting (LSC) system. Light emission in the scintillating solution, transmission through the vial and reflector design are some aspects that need to be considered in detail. This paper describes measurements and calculations carried out to optimise these factors for the design of a new family of LSC counters. Measurements of the light distribution emitted by a scintillation vial were done by autoradiographs of cylindrical vials made of various materials and results were compared to those obtained by direct measurements of the light distribution made by scanning the vial with a photomultiplier tube. Calculations were also carried out to study the light transmission in the vial and the optimal design of the reflector for a system with one photomultiplier tube. (Author)

  2. Radioactive flow detectors: liquid or solid scintillators

    International Nuclear Information System (INIS)

    Reich, A.R.

    1983-01-01

    During the past five years, two schools of thought have emerged producing two different types of radio-HPLC detectors. Based on the naphthalene-in-the-vial principle, manufacturers have developed heterogeneous scintillation detectors. In these detectors the anthracene or naphthalene crystals are replaced by other scintillators. In order to avoid dead space and turbulence, a narrow diameter tube is used, either straight, or more popularly formed into a coil or a 'U' as the cell. To optimize light transmission to the photomultiplier tubes, mirrors are used. Due to limiting factors in this technique the counting efficiency for tritium is below the 10 percent level. The other school of radio-HPLC detectors based their design on classical liquid scintillation counting technology. In a homogeneous detector, the effluent from the HPLC system is mixed with a suitable liquid scintillator before entering the counting cell. The cell design is typically a flat glass or Teflon coil tightly sandwiched between two photomultiplier tubes, making good optical contact without the use of mirrors. Depending on the chromatographic effluent, 3 H efficiencies between 25 to 50 percent, and 14 C counting efficiencies up to 85 percent can be achieved

  3. Liquid scintillator calorimetry for the LHC

    International Nuclear Information System (INIS)

    Artamonov, A.; Buontempo, S.; Epstein, V.; Ereditato, A.; Fiorillo, G.; Garufi, F.; Golovkin, S.; Gorbunov, P.; Jemanov, V.; Khovansky, V.; Kruchinin, S.; Maslennikov, A.; Medvedkov, A.; Vasilchenko, V.; Zaitsev, V.; Zuckerman, I.

    1995-01-01

    We report on the beam tests of full scale liquid scintillator modules designed for a very forward calorimeter for an experiment at the CERN Large Hadron Collider (LHC). Tests were performed in the electron beams of the SPS at CERN within the 20 and 150 GeV energy range. The response as a function of the beam impact point and incidence angle was measured. (orig.)

  4. Temperature quenching in LAB based liquid scintillator

    Energy Technology Data Exchange (ETDEWEB)

    Soerensen, A.; Zuber, K. [Technische Universitaet Dresden, Institute for Nuclear- and Particle Physics, Dresden (Germany); Hans, S.; Yeh, M. [Brookhaven National Laboratory, Chemistry Devision, Upton, NY (United States); Junghans, A.R.; Koegler, T.; Wagner, A. [Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Krosigk, B. v. [Technische Universitaet Dresden, Institute for Nuclear- and Particle Physics, Dresden (Germany); University of British Columbia, Department of Physics and Astronomy, Vancouver, BC (Canada); Lozza, V. [Technische Universitaet Dresden, Institute for Nuclear- and Particle Physics, Dresden (Germany); Laboratorio de Instrumentacao e Fisica Experimental de Particulas, Lisboa (Portugal)

    2018-01-15

    The effect of temperature changes on the light output of LAB based liquid scintillator is investigated in a range from -5 to 30 C with α-particles and electrons in a small scale setup. Two PMTs observe the scintillator liquid inside a cylindrically shaped aluminum cuvette that is heated or cooled and the temperature dependent PMT sensitivity is monitored and corrected. The α-emitting isotopes in dissolved radon gas and in natural Samarium (bound to a LAB solution) excite the liquid scintillator mixtures and changes in light output with temperature variation are observed by fitting light output spectra. Furthermore, also changes in light output by compton electrons, which are generated from external calibration γ-ray sources, is analysed with varying temperature. Assuming a linear behaviour, a combined negative temperature coefficient of (-0.29 ± 0.01)%/ C is found. Considering hints for a particle type dependency, electrons show (-0.17 ± 0.02)%/ C, whereas the temperature dependency seems stronger for α-particles, with (-0.35 ± 0.03)%/ C. Due to a high sampling rate, a pulse shape analysis can be performed and shows an enhanced slow decay component at lower temperatures, pointing to reduced non-radiative triplet state de-excitations. (orig.)

  5. Background characterization in a liquid scintillation spectrometer

    International Nuclear Information System (INIS)

    Rodriguez Barquero, L.; Los Arcos, J.M.; Jimenez de Mingo, A.

    1995-01-01

    An alternate procedure for background count rate estimation in a liquid scintillation spectrometer is presented, which does not require to measure a blank with similar composition, volume and quench, to the problem sample. The procedure is based on a double linear parameterization which was obtained from a systematic study of the background observed with glass vials, in three different windows, 0 - 20 KeV, 0 - 800 KeV and 0 - 2 MeV, for volume between 2 and 20 mi of three commercial scintillators, Hisafe II, Ultima-Gold and Instagel, and quenching degree in the interval equivalent to 50% - 3% tritium efficiency. This procedure was tested with standard samples of 3H, and led to average discrepancies less than 10% for activity ≥0,6 Bq, against conventional methods for which the discrepancies are twice on average. (Author) 10 refs

  6. Background characterization in a liquid scintillation spectrometer

    International Nuclear Information System (INIS)

    Rodriguez Barquero, L.; Los arcos, J.M.; Jimenez de Mingo, A.

    1995-01-01

    An alternate procedure for background count rate estimation in a liquid scintillation spectrometer is presented, which does not require to measure a blank with similar composition, volume and quench, to the problem sample. The procedure is based on a double linear parameterization which was obtained from a systematic study of the background observed with glass vials, in three different windows, 0-20 KeV, 0-800 KeV and 0-2 MeV, for volume between 2 and 20 ml of three commercial scintillators, Hisafe II, Ultima-gold and Instagel, and quenching degree in the interval equivalent to 50%-3% tritium efficiency. This procedure was tested with standard samples of ''3 H, and led to average discrepancies less than 10% for activity => 0,6 Bq, against conventional methods for which the discrepancies are twice on average

  7. Liquid scintillation alpha particle spectrometry. Progress report

    International Nuclear Information System (INIS)

    Bell, L.L.; Hakooz, S.A.; Johnson, L.O.; Nieschmidt, E.B.; Meikrantz, D.H.

    1979-12-01

    Objective to develop a technique whereby Pu may be put into solution, extracted by solvent extraction into a suitable extractive scintillant and subsequently counted. Presented here are results of attempts to separate beta and alpha activities through pulse shape discrimination. A qualitative discussion is given which yields alpha particle peak widths, resolution and response. The detection efficiency for alpha particles in a liquid scintillant is 100%. Present detection sensitivities of the equipment being used are: 4.5 x 10 -6 μCi (100 s), 1.2 x 10 -6 μCi (1000 s), and 4.0 x 10 -7 μCi (10,000 s) at the 3 sigma level. The detectability of a particular alpha-emitting species is strongly dependent upon the population of other species. The ability to discriminate depends upon the system resolution. 14 figures, 2 tables

  8. New liquid scintillators for fiber-optic applications

    International Nuclear Information System (INIS)

    Lutz, S.S.; Franks, L.A.; Flournoy, J.M.; Lyons, P.B.

    1981-01-01

    New long-wavelength-emitting, high-speed, liquid scintillators have been developed and tailored specifically for plasma diagnostic experiments employing fiber optics. These scintillators offer significant advantages over commercially available plastic scintillators in terms of sensitivity and bandwidth. FWHM response times as fast as 350 ps have been measured. Emission spectra, time response data, and relative sensitivity information are presented

  9. Marine radioactivity measurements with liquid scintillation spectrometers

    International Nuclear Information System (INIS)

    Liong Wee Kwong, L.; Povinec, P.P.

    1999-01-01

    Liquid Scintillation Spectrometry (LSS) has now become the most widespread method for quantitative analytical measurement of low levels of β-emitting radionuclides like 3 H and 14 C. The high efficiency resulting from the latest development in LSS makes this technique not only appropriate but also enables direct measurement in environmental samples without excessive preparation. The introduction of several new cocktails based on solvents with a high flashpoint containing surfactants and having a high degree of aqueous sample compatibility has also contributed to the simplification of procedures

  10. Compositions and process for liquid scintillation counting

    International Nuclear Information System (INIS)

    Kauffman, J.M.

    1976-01-01

    Liquid scintillation counting compositions which include certain polyethoxylated poly(oxypropylene) emulsifiers allow stable dispersion of aqueous or other samples merely by shaking. Preferred are mixtures of such emulsifiers, which give homogeneous, monophasic-appearing dispersions over wide ranges of temperature and aqueous sample content. Certain of these emulsifiers, without being mixed, are of particular advantage when used in analysis of samples obtained through radioimmunoassay techniques, which are extremely difficult to disperse. Certain of these emulsifiers, also without being mixed, uniformly give homogeneous, monophasic appearing aqueous couting samples over much wider ranges of aqueous sample content and temperature than prior sample emulsifiers

  11. Compositions and process for liquid scintillation counting

    International Nuclear Information System (INIS)

    Kauffman, J.M.

    1978-01-01

    Liquid scintillation compositions which include certain polyethoxylated poly(oxypropylene) emulsifiers allow stable dispersion of aqueous or other samples merely by shaking. Preferred are mixtures of such emulsifiers, which give homogeneous, monophasic-appearing dispersions over wide ranges of temperature and aqueous sample content. Certain of these emulsifiers, without being mixed, are of particular advantage when used in analysis of samples obtained through radioimmunoassay techniques, which are extremely difficult to disperse. Certain of these emulsifiers, also without being mixed, uniformly give homogeneous, monophasic appearing aqueous counting samples over much wider ranges of aqueous sample content and temperature than prior sample emulsifiers

  12. Compositions and process for liquid scintillation counting

    International Nuclear Information System (INIS)

    1974-01-01

    Liquid scintillation counting compositions which include certain polyethoxylated poly(oxypropylene) emulsifiers allow stable dispersion of aqueous or other samples merely by shaking. Preferred are mixtures of such emulsifiers which give homogeneous monophasic-appearing dispersions over wide ranges of temperature and aqueous sample content. Certain of these emulsifiers, without being mixed, are of particular advantage when used in analysis of samples obtained through radioimmunoassay techniques which are extremely difficult to disperse. Certain of these emulsifiers, also without being mixed, uniformly give homogeneous monophasic-appearing aqueous counting samples over much wider ranges of aqueous sample content and temperature than prior sample emulsifiers

  13. Study on determination of 90Sr by liquid scintillation spectrometry

    International Nuclear Information System (INIS)

    Zhai Xiufang; Li Weiping; Tian Mei; Zou Ronghu

    2012-01-01

    Both of Liquid scintillation counting and Cerenkov counting can be used to determinate 90 Sr in samples by Liquid scintillation spectrometry. In this work, effects of scintillation vials wit-h different material, Liquid scintillation cocktails, sample volume, Strontium carrier, pH, quenching (chemical quenching and color quenching)are studied, and both counting methods are compared. For Liquid scintillation counting. The results show that the best appropriate volume ratio of sample and liquid scintillation cocktail is 8:12 for OPTIPHASE HISAFE-3 and OPTIPHASE HISAFE-2, stability of solution decreased when sample load exceeds the maximum load for both Liquid scintillation cocktails, and OPTIPHASE HISAFE-3 also show superior performance for high saline solution. The type of scintillation vial haven't clear influence on the MDA of 90 Sr. Chemical quenching and color quenching can decrease the counting efficiency. For Cerenkov counting, the lowest MDA is obtained when polyethylene plastic vial is used and sample volume is 20 ml. Color quenching decreases the counting efficiency, while there isn't chemical quenching for Cerenkov counting. The MDA of 90 Sr is 1.19 and 1.00 Bq/L for Liquid scintillation counting and Cerenkov counting with the optimal labeling condition. (authors)

  14. Liquid-helium scintillation detection with germanium photodiodes

    International Nuclear Information System (INIS)

    Luke, P.N.; Haller, E.E.; Steiner, H.M.

    1982-05-01

    Special high-purity germanium photodiodes have been developed for the direct detection of vacuum ultraviolet scintillations in liquid helium. The photodiodes are immersed in the liquid helium, and scintillations are detected through one of the bare sides of the photodiodes. Test results with scintillation photons produced by 5.3-MeV α particles are presented. The use of these photodiodes as liquid-helium scintillation detectors may offer substantial improvements over the alternate detection method requiring the use of wavelength shifters and photomultiplier tubes

  15. Liquid Scintillation Detectors for High Energy Neutrinos

    International Nuclear Information System (INIS)

    Smith, Stefanie N.; Learned, John G.

    2010-01-01

    Large open volume (not segmented) liquid scintillation detectors have been generally dedicated to low energy neutrino measurements, in the MeV energy region. We describe the potential employment of large detectors (>1 kiloton) for studies of higher energy neutrino interactions, such as cosmic rays and long-baseline experiments. When considering the physics potential of new large instruments the possibility of doing useful measurements with higher energy neutrino interactions has been overlooked. Here we take into account Fermat's principle, which states that the first light to reach each PMT will follow the shortest path between that PMT and the point of origin. We describe the geometry of this process, and the resulting wavefront, which we are calling the 'Fermat surface', and discuss methods of using this surface to extract directional track information and particle identification. This capability may be demonstrated in the new long-baseline neutrino beam from Jaeri accelerator to the KamLAND detector in Japan. Other exciting applications include the use of Hanohano as a movable long-baseline detector in this same beam, and LENA in Europe for future long-baseline neutrino beams from CERN. Also, this methodology opens up the question as to whether a large liquid scintillator detector should be given consideration for use in a future long-baseline experiment from Fermilab to the DUSEL underground laboratory at Homestake.

  16. Liquid emulsion scintillators which solidify for facile disposal

    International Nuclear Information System (INIS)

    O'Brien, R.E.; Krieger, J.K.

    1981-01-01

    A liquid organic scintillation cocktail is described which counts solutions of radiolabelled compounds containing up to ten % by volume of water with high efficiency and is readily polymerizable to a solid for easy disposal. The cocktail comprises a polymerizable organic solvent, a solubilizing agent, an intermediate solvent, and an organic scintillator. A method of disposing of liquid organic scintillation cocktail waste and a kit useful for practising the method are also described. (U.K.)

  17. Some history of liquid scintillator development at Los Alamos

    International Nuclear Information System (INIS)

    Ott, D.G.

    1979-01-01

    The early developments in liquid scintillation counting made at Los Alamos Scientific Laboratory are reviewed. Most of the work was under the direction of F.N. Hayes and included counter development and applications as well as synthesis and chemistry of liquid scintillators

  18. Data process of liquid scintillation counting

    International Nuclear Information System (INIS)

    Ishikawa, Hiroaki; Kuwajima, Susumu.

    1975-01-01

    The use of liquid scintillation counting system has been significantly spread because automatic sample changers and printers have recently come to be incorporated. However, the system will be systematized completely if automatic data processing and the sample preparation of radioactive materials to be measured are realized. Dry or wet oxidation method is applied to the sample preparation when radioactive materials are hard to dissolve into scintillator solution. Since these several years, the automatic sample combustion system, in which the dry oxidation is automated, has been rapidly spread and serves greatly to labor saving. Since the printers generally indicate only counted number, data processing system has been developed, and speeded up calculating process, which automatically corrects quenching of samples for obtaining the final radioactivity required. The data processing system is roughly divided into on-line and off-line systems according to whether computers are connected directly or indirectly, while its hardware is classified to input, calculating and output devices. Also, the calculation to determine sample activity by external standard method is explained. (Wakatsuki, Y.)

  19. Investigation of organic liquid-scintillator optical properties

    Energy Technology Data Exchange (ETDEWEB)

    Winter, Juergen; Feilitzsch, Franz von; Goeger-Neff, Marianne; Lewke, Timo; Meindl, Quirin; Oberauer, Lothar; Potzel, Walter; Todor, Sebastian; Wurm, Michael [Physik Department E15, Technische Universitaet Muenchen, James-Franck-Str., 85748 Garching (Germany); Marrodan Undagoitia, Teresa [Physik Department E15, Technische Universitaet Muenchen, James-Franck-Str., 85748 Garching (Germany); Physik-Institut, Universitaet Zuerich (Switzerland)

    2009-07-01

    The characterization of different organic liquid-scintillator mixtures is an important step towards the design of a large-scale detector such as LENA (Low Energy Neutrino Astronomy). Its physics goals, extending from particle and geological to astrophysical issues, set high demands on the optical properties of the liquid scintillator. Therefore, small-scale experiments are carried out in order to optimize the final scintillator mixture. PXE, LAB, and dodecane are under consideration as solvents. Setups for the determination of scintillator properties are presented, such as attenuation length, light yield, emission spectra, fluorescence decay times, and quenching factors. Furthermore, results are discussed.

  20. An efficient energy response model for liquid scintillator detectors

    Science.gov (United States)

    Lebanowski, Logan; Wan, Linyan; Ji, Xiangpan; Wang, Zhe; Chen, Shaomin

    2018-05-01

    Liquid scintillator detectors are playing an increasingly important role in low-energy neutrino experiments. In this article, we describe a generic energy response model of liquid scintillator detectors that provides energy estimations of sub-percent accuracy. This model fits a minimal set of physically-motivated parameters that capture the essential characteristics of scintillator response and that can naturally account for changes in scintillator over time, helping to avoid associated biases or systematic uncertainties. The model employs a one-step calculation and look-up tables, yielding an immediate estimation of energy and an efficient framework for quantifying systematic uncertainties and correlations.

  1. Cherenkov and scintillation light separation in organic liquid scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Caravaca, J.; Descamps, F.B.; Land, B.J.; Orebi Gann, G.D. [University of California, Berkeley, CA (United States); Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Yeh, M. [Brookhaven National Laboratory, Upton, NY (United States)

    2017-12-15

    The CHErenkov/Scintillation Separation experiment (CHESS) has been used to demonstrate the separation of Cherenkov and scintillation light in both linear alkylbenzene (LAB) and LAB with 2 g/L of PPO as a fluor (LAB/PPO). This is the first successful demonstration of Cherenkov light detection from the more challenging LAB/PPO cocktail and improves on previous results for LAB. A time resolution of 338 ± 12 ps FWHM results in an efficiency for identifying Cherenkov photons in LAB/PPO of 70 ± 3% and 63 ± 8% for time- and charge-based separation, respectively, with scintillation contamination of 36 ± 5% and 38 ± 4. LAB/PPO data is consistent with a rise time of τ{sub r} = 0.72 ± 0.33 ns. (orig.)

  2. Cherenkov and scintillation light separation in organic liquid scintillators

    International Nuclear Information System (INIS)

    Caravaca, J.; Descamps, F.B.; Land, B.J.; Orebi Gann, G.D.; Yeh, M.

    2017-01-01

    The CHErenkov/Scintillation Separation experiment (CHESS) has been used to demonstrate the separation of Cherenkov and scintillation light in both linear alkylbenzene (LAB) and LAB with 2 g/L of PPO as a fluor (LAB/PPO). This is the first successful demonstration of Cherenkov light detection from the more challenging LAB/PPO cocktail and improves on previous results for LAB. A time resolution of 338 ± 12 ps FWHM results in an efficiency for identifying Cherenkov photons in LAB/PPO of 70 ± 3% and 63 ± 8% for time- and charge-based separation, respectively, with scintillation contamination of 36 ± 5% and 38 ± 4. LAB/PPO data is consistent with a rise time of τ r = 0.72 ± 0.33 ns. (orig.)

  3. Solid scintillator 'Ready Cap' for measurement with a liquid scintillation counter

    International Nuclear Information System (INIS)

    Ijiri, Kenichi; Endo, Masashi; Nogawa, Norio; Tsuda, Shoko; Nakamura, Aiko; Morikawa, Naotake; Osaki, Susumu.

    1990-01-01

    'Ready Cap', a small plastic container coated with solid scintillator has recently been introduced (Beckman Instruments, Inc.). Pulse height spectra and counting efficiencies obtained with a liquid scintillator and Ready Cap using a liquid scintillation counter were compared for 15 different radionuclides. For radionuclides emitting low-energy β-rays or characteristic X-rays, the spectra for Ready Cap shifted toward the higher energy side compared with the spectra for the liquid scintillator. This tendency was reversed for the nuclides emitting higher-energy β-radiations ( 36 Cl and 32 P). Generally, counting efficiencies both in Ready Cap and in liquid scintillator increased with increase in the energy of β- or X-rays. For some nuclides, Ready Cap gave higher counting efficiencies and for others it gave lower values than in the liquid scintillator. However, the differences were not large within each nuclide. The use of Ready Cap is recommended for measurements of radionuclides when liquid scintillation cocktails have no means of waste disposal under the present Japanese radioisotope regulation. (author)

  4. Liquid scintillation counting analysis of cadmium-109

    International Nuclear Information System (INIS)

    Robinson, M.K.; Barfuss, D.W.

    1991-01-01

    Recently the authors have used radiolabled cadmium-109 to measure the transport of inorganic cadmium in renal proximal tubules. An anomaly discovered in the liquid scintillation counting analysis of Cd-109 which is not attributable to normal decay; it consists of a significant decrease in the measured count rate of small amounts of sample. The objective is to determine whether the buffer solution used in the membrane transport studies is causing precipitation of the cadmium or whether cadmium is being adsorbed by the glass. It was important to determine whether the procedure could be modified to correct this problem. The problem does not appear to be related to the use of the buffer or to adsorption of Cd onto glass. Correction based on using triated L-glucose in all of these experiments and calculating a correction factor for the concentration of cadmium

  5. Upgradation of automatic liquid scintillation counting system

    International Nuclear Information System (INIS)

    Bhattacharya, Sadhana; Behere, Anita; Sonalkar, S.Y.; Vaidya, P.P.

    2001-01-01

    This paper describes the upgradation of Microprocessor based Automatic Liquid Scintillation Counting systems (MLSC). This system was developed in 1980's and subsequently many systems were manufactured and supplied to Environment Survey labs at various Nuclear Power Plants. Recently this system has been upgraded to a more sophisticated one by using PC add-on hardware and developing Windows based software. The software implements more intuitive graphical user interface and also enhances the features making it comparable with commercially available systems. It implements data processing using full spectrum analysis as against channel ratio method adopted earlier, improving the accuracy of the results. Also it facilitates qualitative as well as quantitative analysis of the β-spectrum. It is possible to analyze a sample containing an unknown β-source. (author)

  6. A new method of quench monitoring in liquid scintillation counting

    International Nuclear Information System (INIS)

    Horrocks, D.L.

    1978-01-01

    The quench level of different liquid scintillation counting samples is measured by comparing the responses (pulse heights) produced by the same energy electrons in each sample. The electrons utilized in the measurements are those of the maximum energy (Esub(max)) which are produced by the single Compton scattering process for the same energy gamma-rays in each sample. The Esub(max) response produced in any sample is related to the Esub(max) response produced in an unquenched, sealed standard. The difference in response on a logarithm response scale is defined as the ''H Number''. The H number is related to the counting efficiency of the desired radionuclide by measurement of a set of standards of known amounts of the radionuclide and different amounts of quench (standard quench curve). The concept of the H number has been shown to be theoretically valid. Based upon this proof, the features of the H number concept as embodied in the Beckman LS-8000 Series Liquid Scintillation Systems have been demonstrated. It has been shown that one H number is unique; it provides a method of instrument calibration and wide dynamic quench range measurements. Further, it has been demonstrated that the H number concept provides a universal quench parameter. Counting efficiency vs. H number plots are repeatable within the statistical limits of +-1% counting efficiency. By the use of the H number concept a very accurate method of automatic quench compensation (A.Q.C.) is possible. (T.G.)

  7. Liquid Scintillation High Resolution Spectral Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Grau Carles, A.; Grau Malonda, A.

    2010-08-06

    The CIEMAT/NIST and the TDCR methods in liquid scintillation counting are based on the determination of the efficiency for total counting. This paper tries to expand these methods analysing the pulse-height spectrum of radionuclides. To reach this objective we have to generalize the equations used in the model and to analyse the influence of ionization and chemical quench in both spectra and counting efficiency. We present equations to study the influence of different photomultipliers response in systems with one, two or three photomultipliers. We study the effect of the electronic noise discriminator level in both spectra and counting efficiency. The described method permits one to study problems that up to now was not possible to approach, such as the high uncertainty in the standardization of pure beta-ray emitter with low energy when we apply the TDCR method, or the discrepancies in the standardization of some electron capture radionuclides, when the CIEMAT/NIST method is applied. (Author) 107 refs.

  8. Liquid Scintillation High Resolution Spectral Analysis

    International Nuclear Information System (INIS)

    Grau Carles, A.; Grau Malonda, A.

    2010-01-01

    The CIEMAT/NIST and the TDCR methods in liquid scintillation counting are based on the determination of the efficiency for total counting. This paper tries to expand these methods analysing the pulse-height spectrum of radionuclides. To reach this objective we have to generalize the equations used in the model and to analyse the influence of ionization and chemical quench in both spectra and counting efficiency. We present equations to study the influence of different photomultipliers response in systems with one, two or three photomultipliers. We study the effect of the electronic noise discriminator level in both spectra and counting efficiency. The described method permits one to study problems that up to now was not possible to approach, such as the high uncertainty in the standardization of pure beta-ray emitter with low energy when we apply the TDCR method, or the discrepancies in the standardization of some electron capture radionuclides, when the CIEMAT/NIST method is applied. (Author) 107 refs.

  9. Current status of liquid scintillation counting

    International Nuclear Information System (INIS)

    Klingler, G.W.

    1981-01-01

    Scintillation counting of alpha particles has been used since the turn of the century. The advent of pulse shape discrimination has made this method of detection accurate and reliable. The history, concepts and development of scintillation counting and pulse shape discrimination are discussed. A brief look at the ongoing work in the consolidation of components now used for pulse shape discrimination is included

  10. Large liquid-scintillator trackers for neutrino experiments

    CERN Document Server

    Benussi, L; D'Ambrosio, N; Déclais, Y; Dupraz, J P; Fabre, Jean-Paul; Fanti, V; Forton, E; Frekers, D; Frenkel, A; Girerd, C; Golovkin, S V; Grégoire, G; Harrison, K; Jonkmans, G; Jonsson, P; Katsanevas, S; Kreslo, I; Marteau, J; Martellotti, G; Martínez, S; Medvedkov, A M; Moret, G; Niwa, K; Novikov, V; Van Beek, G; Penso, G; Vasilchenko, V G; Vuilleumier, J L; Wilquet, G; Zucchelli, P; Kreslo, I E

    2002-01-01

    Results are given on tests of large particle trackers for the detection of neutrino interactions in long-baseline experiments. Module prototypes have been assembled using TiO$_2$-doped polycarbonate panels. These were subdivided into cells of $\\sim 1$~cm$^2$ cross section and 6~m length, filled with liquid scintillator. A wavelength-shifting fibre inserted in each cell captured a part of the scintillation light emitted when a cell was traversed by an ionizing particle. Two different fibre-readout systems have been tested: an optoelectronic chain comprising an image intensifier and an Electron Bombarded CCD (EBCCD); and a hybrid photodiode~(HPD). New, low-cost liquid scintillators have been investigated for applications in large underground detectors. Testbeam studies have been performed using a commercially available liquid scintillator. The number of detected photoelectrons for minimum-ionizing particles crossing a module at different distances from the fibre readout end was 6 to 12 with the EBCCD chain and ...

  11. Liquid scintillation cocktails comparison for tritium contamination measurements

    International Nuclear Information System (INIS)

    Bazzarri, S.; Belloni, P.

    1996-01-01

    Liquid scintillation counting is one of the most used techniques for the measurements of tritium contamination. Until few years ago a problem related to this kind of measurement was the potential toxicity of the liquid cocktails used to produce the required scintillation. Some new products that guarantee an almost negligible impact on the environment and that are no longer toxic for the operators are now available. Some of this new scintillation cocktail are suitable to be used for tritium measurement. Due to the great benefit from the health point of view of these new materials a test of their scintillation performance has been done at the ENEA centers to select the product having the best characteristics for tritium measurement. (author)

  12. Scintillation trigger system of the liquid argon neutrino detector

    International Nuclear Information System (INIS)

    Belikov, S.V.; Gurzhiev, S.N.; Gutnikov, Yu.E.; Denisov, A.G.; Kochetkov, V.I.; Matveev, M.Yu.; Mel'nikov, E.A.; Usachev, A.P.

    1994-01-01

    This paper presents the organization of the Scintillation Trigger System (STS) for the Liquid Argon Neutrino Detector of the Tagged Neutrino Facility. STS is aimed at the effective registration of the needed neutrino interaction type and production of a fast trigger signal with high time resolution. The fast analysis system of analog signal from the trigger scintillation planes for rejection of the trigger signals from background processes is described. Real scintillation trigger planes characteristics obtained on the basis of the presented data acquisition system are shown. 10 refs., 12 figs., 3 tabs

  13. Infrared scintillation: a comparison between gaseous and liquid xenon

    International Nuclear Information System (INIS)

    Bressi, G.; Carugno, G.; Conti, E.; Del Noce, C.; Iannuzzi, D.

    2001-01-01

    Light yield and spectrum of infrared (IR) scintillation in Xe are different in gaseous and liquid phases. In gas, the spectrum consists mainly of a broad line centered at 1300 nm. In liquid, light is emitted primarily below 1200 nm and with a lower yield

  14. New scintillating media based on liquid crystals for particle detectors

    International Nuclear Information System (INIS)

    Barnik, M.I.; Yudin, S.G.; Vasil'chenko, V.G.; Golovkin, S.V.; Medvedkov, A.M.; Solovjev, A.S.

    2000-01-01

    The study results of optical, photoluminiscent and scintillation properties of a liquid crystal 4-pentyl-4'-cyanobiphenyl are presented. The scintillation light output of this liquid crystal is about 35% of crystal anthracene, its main decay time constants are 4 and 14 ns, and the maximum of light emission spectrum is about 400 nm. The light output of a dissolution of green emitting light scintillation dopant R6 in the liquid crystal is about 120% of crystal anthracene. The light output of the frozen dissolution measured at -112 deg. C is about 2.5 times higher as observed at +20 deg. C. In the uniaxially oriented liquid crystal, the predominant intensity direction of emitted light is pointed perpendicular to the liquid crystal director and an appreciable part of the emitted light is elliptically polarized. The possibility to use scintillation properties of liquid crystals is considered both for the improvement of existing particle detector characteristics and for the creation of new gated particle detectors

  15. New scintillating media based on liquid crystals for particle detectors

    CERN Document Server

    Barnik, M I; Vasilchenko, V G; Golovkin, S V; Medvedkov, A M; Soloviev, A S

    2000-01-01

    The study results of optical, photoluminiscent and scintillation properties of a liquid crystal 4-pentyl-4'-cyanobiphenyl are presented. The scintillation light output of this liquid crystal is about 35% of crystal anthracene, its main decay time constants are 4 and 14 ns, and the maximum of light emission spectrum is about 400 nm. The light output of a dissolution of green emitting light scintillation dopant R6 in the liquid crystal is about 120% of crystal anthracene. The light output of the frozen dissolution measured at -112 deg. C is about 2.5 times higher as observed at +20 deg. C. In the uniaxially oriented liquid crystal, the predominant intensity direction of emitted light is pointed perpendicular to the liquid crystal director and an appreciable part of the emitted light is elliptically polarized. The possibility to use scintillation properties of liquid crystals is considered both for the improvement of existing particle detector characteristics and for the creation of new gated particle detectors.

  16. Determination of thoron and radon ratio by liquid scintillation spectrometry

    International Nuclear Information System (INIS)

    Yoshikawa, H.; Nakanishi, T.; Nakahara, H.

    2006-01-01

    A portable liquid scintillation counter was applied for the analysis of alpha-ray energy spectrum to determine the ratio of 220 Rn/ 222 Rn in fumarolic gas in the field. A surface-polished vial was developed, by which a Gaussian distribution could be approximated for the alpha-ray energy spectra and the peak areas of the nuclides could be estimated independently, because of the wide FWHM in the liquid scintillation pulse. A fumarolic gas sample was collected in Mt. Kamiyama (Hakoneyama geothermal field in Japan) having low 220 Rn/ 222 Rn ratio of 2.20 ± 0.13. (author)

  17. Use of pliable bags in liquid scintillation counting

    International Nuclear Information System (INIS)

    Simonnet, G.; Jacquet, M.A.; Sharif, A.; Engler, R.

    1981-01-01

    Pliable plastic bags have been used to replace glass or plastic vials for liquid scintillation counting. The two major advantages of this method are the lower cost of the plastic bags and the fact that, per sample, the radioactive waste is significantly reduced. The following parameters have been checked: the impermeability of the bags to various scintillator mixtures and the fact that neither the irregular shape of the bags nor their position in the counting chamber had any effect on the results of the counting. The latter was also constant with time, at least over a period of 10 days. The technique has been used to count the radioactivity of 3 H-DNA precipitates prepared from bacteria and lymphocytes and deposited on filters impregnated with only 200 μl scintillator. It is a method that can be applied to the counting of any samples deposited on filters and insoluble in scintillator. (author)

  18. LET dependence of scintillation yields in liquid argon

    Energy Technology Data Exchange (ETDEWEB)

    Doke, Tadayoshi; Hitachi, Akira; Kikuchi, Jun; Crawford, H J; Lindstrom, P J; Masuda, Kimiaki; Shibamura, Eido; Takahashi, Tan

    1988-06-01

    Scintillation yields (scintillation intensity per unit absorbed energy) in liquid argon for ionizing particles are reviewed as a function of LET for the particles. The maximum scintillation yield, which is obtained for relativistic heavy ions from Ne to La, is about 1.2 times larger than that for gamma rays in NaI(Tl) crystal. In the low LET region, the scintillation yields for relativistic electrons, protons and He ions are 10-20% lower than the maximum yield. This tendency can be explained by taking into account the existence of the electrons which have escaped from their parent ions. In the high LET region, a quenching effect due to high ionization density is observed for alpha particles, fission fragments and relativistic Au ions.

  19. Determination of 226Ra by alpha spectrometry of liquid scintillation

    International Nuclear Information System (INIS)

    Nobrega, A.W.; Sachett, I.A.; Hespanhol, E.C.B.

    1987-01-01

    The determination of 226 Ra in environmental samples using alpha spectrometry in liquid scintilation is studied. The Radon 1-2 emanation method and 226 Ra separation process of other radionuclides alpha emissors are analyzed. The use of 226 Ra coprecipitation with barium sulphate is evaluated. (M.J.C.) [pt

  20. Selective solvent extraction of actinides associated to liquid scintillation measurements

    International Nuclear Information System (INIS)

    Ardois, C.; Musikas, C.

    1997-01-01

    The problems associated to radioactive waste disposal have acquired a special attention due, particularly, to the element instability and, consequently, to their lixiviation and to their peculiarities which are essential in the radioactivity penetration in the food chains; the other important parameters are the produced amounts and the noxiousnesses. New commercial liquid scintillation counters allow rapid α/β measurements. Associated with liquid-liquid extraction techniques, rapid and selective actinide analyses are possible. Among various actinide extractants, such as amines or organophosphorus compounds, we were particularly interested in tri-n-octyl-phosphine oxide (TOPO). Uranium, thorium and americium extractions with (TOPO) in toluene have been investigated. A systematic study of the counting parameters of a PACKARD 2550 TR/AB TM liquid scintillation analyzer is under completion

  1. Performance of Water-Based Liquid Scintillator: An Independent Analysis

    Directory of Open Access Journals (Sweden)

    D. Beznosko

    2014-01-01

    Full Text Available The water-based liquid scintillator (WbLS is a new material currently under development. It is based on the idea of dissolving the organic scintillator in water using special surfactants. This material strives to achieve the novel detection techniques by combining the Cerenkov rings and scintillation light, as well as the total cost reduction compared to pure liquid scintillator (LS. The independent light yield measurement analysis for the light yield measurements using three different proton beam energies (210 MeV, 475 MeV, and 2000 MeV for water, two different WbLS formulations (0.4% and 0.99%, and pure LS conducted at Brookhaven National Laboratory, USA, is presented. The results show that a goal of ~100 optical photons/MeV, indicated by the simulation to be an optimal light yield for observing both the Cerenkov ring and the scintillation light from the proton decay in a large water detector, has been achieved.

  2. PMP, a novel solute for liquid and plastic scintillation counting

    International Nuclear Information System (INIS)

    Gusten, Hans

    1983-01-01

    The excellent fluorescence properties of PMP ( 11-phenyl-3-mesityl-2-pyrazoline) such as long wavelength emission of over 400 nm, and high fluorescence quantum yield with a short decay time together with a solubility of more than one Mol/L in toluene make this compound a promising solute for scintillation counting. The Stokes' shift of PMP of over 10,000 cm -1 is twice as large as that of the commonly used PPO. Due to this unusually large Stokes' shift PMP can be used as a primary solute without requiring a secondary solute as wavelength shifter. A comparison of the scintillation properties of PMP and PPO in toluene reveals that the counting efficiency for 14 C is better for PMP while the 3 H efficiency is equally good. Due to the large Stokes' shift, PMP is about 50 percent less sensitive to color quenching than PPO. Compared to the solute combinations PPO/secondary solutes, the scintillation counting efficiency of PMP for 14 C in toluene or xylene is the same, while the absolute 3 H efficiency of PPO/secondary solutes in cocktails with emulsifiers is about 10 percent higher. The PMP scintillation efficiency for 14 C as well as 3 H in chemical quenching by urine is more or less the same as for PPO/dimethyl-POPOP. PMP is more sensitive to quenching by halogenated solvents. In the dioxane-based scintillation, this sensitivity to chemical quenching by CHCl 3 vanishes and the counting efficiencies for 14 C and 3 H are as good as for PPO/dimethyl-POPOP or PPO/bis-MSB. Due to the large Stokes' shift, the self-absorption of the scintillation light by PMP is lower than in conventional scintillators. This offers good possibilities in very large-volume applications of liquid as well as plastic scintillators

  3. A new water-based liquid scintillator and potential applications

    Energy Technology Data Exchange (ETDEWEB)

    Yeh, M., E-mail: yeh@bnl.gov [Chemistry Department, Brookhaven National Laboratory, Upton, NY 11973 (United States); Hans, S.; Beriguete, W.; Rosero, R.; Hu, L.; Hahn, R.L. [Chemistry Department, Brookhaven National Laboratory, Upton, NY 11973 (United States); Diwan, M.V.; Jaffe, D.E.; Kettell, S.H.; Littenberg, L. [Physics Department, Brookhaven National Laboratory, Upton, NY 11973 (United States)

    2011-12-21

    In this paper we describe a new type of scintillating liquid based on water. We describe the concept, preparation, and properties of this liquid, and how it could be used for a very large, but economical detector. The applications of such a detector range from fundamental physics such as nucleon decay and neutrino physics to physics with broader application such as neutron detection. We briefly describe the scientific requirements of these applications, and how they can be satisfied by the new material.

  4. A new liquid xenon scintillation detector for positron emission tomography

    International Nuclear Information System (INIS)

    Chepel, V.Yu.

    1993-01-01

    A new positron-sensitive detector of annihilation photons filled with liquid xenon is proposed for positron emission tomography. Simultaneous detection of both liquid xenon scintillation and ionization current produces a time resolution of < 1 ns and a position resolution in the tangential direction of the tomograph ring is ∼ 1 mm and in the radial direction is ∼ 5 mm. The advantages of a tomograph with new detectors are discussed. New algorithms of Compton scattering can be used. (author)

  5. Evaluation of the ionization quenching correction for several liquid scintillators

    International Nuclear Information System (INIS)

    Los Arcos, J. M.; Borras, C.

    1990-01-01

    The most appropriate computational model for the ionization quenching function Q(E) is analyzed for electrons in liquid scintillators. A numerical evaluation of Q(E) from 0.1 keV to 3 MeV which the kB parameter varying between 0.005 and 0.010 cm/MeV is presented for seven scintillators; Toluene, Toluene-Alcohol, PCS, Toluene-CCl4, INSTAGEL, Dioxane-Naphtalene and HISAFE II. The numerical result are summarized as tables of Ieast squares fitting coefficient which make easy the computation of Q(E). (Author)

  6. Evaluation of the ionization quenching correction for several liquid scintillators

    International Nuclear Information System (INIS)

    Los Arcos, J.M.; Borras, C.

    1990-01-01

    The most appropiate computational model for the ionization quench-ing function Q(E) is analyzed for electrons in liquid scintillators. A numerical evaluation of Q(E) from 0.1 keV to 3 MeV which the kB parameter varying between 0.005 and 0.010 cm/MeV is presented for seven scintillators; Toluene, Toluene-Alcohol, PCS, Toluene-CC14, INSTAGEL, Dioxane-Naphtalene and HISAFE II. The numerical result are summarized as tables of least squares fitting coefficient which make easy the computation of Q(E).(Author)

  7. Method for determining efficiency in a liquid scintillation system

    International Nuclear Information System (INIS)

    Laney, B.H.

    1975-01-01

    This invention relates to a method of counting radioactive events in a liquid scintillation radiation detecting and counting apparatus by utilizing pulses generated by a photomultiplying means resulting from scintillations caused by radioactive events. A counting efficiency value is assigned to each pulse generated in the photomultiplying means according to the height of the pulse. The numerical inverse of each assigned counting efficiency value is determined and each numerical inverse is recorded as an actual number of radioactive events with each having a pulse height identical to that of the corresponding pulse generated in the photomultiplying means. (Patent Office Record)

  8. Influence of temperature to quenching on liquid scintillation measurement

    CERN Document Server

    Kato, T

    2003-01-01

    The amount of quench is measured with liquid scintillation spectrometer changing the temperature of the sample. The range of the changed temperature is between 0 deg C and 35 deg C. The measurement is carried out for three kinds of unquenched standard, two quenched standards and fifteen kinds of scintillation cocktail and the mixed sample. It is confirmed that the amount of quench increases for all samples as the temperature rises. The influence of the changed amount of quench to the quench correction is examined. (author)

  9. Calculations and measurements of the scintillator-to-water stopping power ratio of liquid scintillators for use in proton radiotherapy

    International Nuclear Information System (INIS)

    Scott Ingram, W.; Robertson, Daniel; Beddar, Sam

    2015-01-01

    Liquid scintillators are a promising detector for high-resolution three-dimensional proton therapy dosimetry. Because the scintillator comprises both the active volume of the detector and the phantom material, an ideal scintillator will exhibit water equivalence in its radiological properties. One of the most fundamental of these is the scintillator’s stopping power. The objective of this study was to compare calculations and measurements of scintillator-to-water stopping power ratios to evaluate the suitability of the liquid scintillators BC-531 and OptiPhase HiSafe 3 for proton dosimetry. We also measured the relative scintillation output of the two scintillators. Both calculations and measurements show that the linear stopping power of OptiPhase is significantly closer to water than that of BC-531. BC-531 has a somewhat higher scintillation output. OptiPhase can be mixed with water at high concentrations, which further improves its scintillator-to-water stopping power ratio. However, this causes the solution to become cloudy, which has a negative impact on the scintillation output and spatial resolution of the detector. OptiPhase is preferred over BC-531 for proton dosimetry because its density and scintillator-to-water stopping power ratio are more water equivalent

  10. New advanced in alpha spectrometry by liquid scintillation methods

    International Nuclear Information System (INIS)

    McDowell, W.J.; Case, G.N.

    1979-01-01

    Although the ability to count alpha particles by liquid scintillation methods has been long recognized, limited use has been made of the method because of problems of high background and alpha energy identification. In recent years some new developments in methods of introducing the alpha-emitting nuclide to the scintillator, in detector construction, and in electronics for processing the energy analog and time analog signals from the detector have allowed significant alleviation of the problems of alpha spectrometry by liquid scintillation. Energy resolutions of 200 to 300 keV full peak width at half maximum and background counts of 99% of all beta plus gamma interference is now possible. Alpha liquid scintillation spectrometry is now suitable for a wide range of applications, from the accurate quantitative determination of relatively large amounts of known nuclides in laboratory-generated samples to the detection and identification of very small, subpicocurie amounts of alpha emitters in environmental-type samples. Suitable nuclide separation procedures, sample preparation methods, and instrument configurations are available for a variety of analyses

  11. Pulse-shape discrimination in NE213 liquid scintillator detectors

    International Nuclear Information System (INIS)

    Cavallaro, M.; Tropea, S.; Agodi, C.; Assié, M.; Azaiez, F.; Boiano, C.; Bondì, M.; Cappuzzello, F.; Carbone, D.; De Napoli, M.; Séréville, N. de; Foti, A.; Linares, R.; Nicolosi, D.; Scarpaci, J.A.

    2013-01-01

    The 16-channel fast stretcher BaFPro module, originally developed for processing signals of Barium Fluoride scintillators, has been modified to make a high performing analog pulse-shape analysis of signals from the NE213 liquid scintillators of the EDEN neutron detector array. The module produces two Gaussian signals, whose amplitudes are proportional to the height of the fast component of the output light and to the total energy deposited into the scintillator, respectively. An in-beam test has been performed at INFN-LNS (Italy) demonstrating a low detection threshold, a good pulse-shape discrimination even at low energies and a wide dynamic range for the measurement of the neutrons energy.

  12. Liquid xenon/krypton scintillation calorimeter

    International Nuclear Information System (INIS)

    Akimov, D.Yu.; Bolozdynya, A.I.; Brastilov, A.D.

    1994-01-01

    A scintillating LXe/LKr electromagnetic calorimeter has been built at the ITEP and tested at the BATES (MIT) accelerator. The detector consists of PMT matrix and 45 light collecting cells made of aluminized 50 microns Mylar partially covered with p-terphenyl as a wavelength-shifter. Each pyramidal cell has (2.1 x 2.1) x 40 x (4.15 x 4.15) cm dimensions and is viewed by FEU-85 glass-window photomultiplier. The detector has been exposed at 106-348 MeV electron beam. The energy resolution σ E /E ≅ 5% √ E at 100 - 350 MeV range in LXe, the coordinate resolution τ x ≅ 0.7 cm, the time resolution for single cell ≅ 0.6 ns have been obtained. Possible ways to improve energy resolution are discussed. 8 refs., 15 figs

  13. Alpha liquid scintillation counting: past, present, and future

    International Nuclear Information System (INIS)

    McDowell, W.J.

    1979-01-01

    Beta liquid scintillation counting has been used for about 30 years, and its effectiveness for alpha particles has been known for almost that long; however, the technique has not been widely applied to alpha particle detection because of poor energy resolution, high background, and variable interference from beta and gamma radiation. Beginning with the work of Horrocks in the early 1960s, improvements in energy resolution and background rejection have been made. Further developments at Oak Ridge National Laboratory over the past 10 to 12 years have resulted in improved methods of sample preparation (using liquid-liquid extraction methods to isolate the sample and introduce it into the scintillator) and better instrumentation, including electronic rejection of beta and gamma pulses. Energy resolutions of 200- to 300-keV FWHM and background counts of 0.01 cpm are now routine. Alpha liquid scintillation spectrometry is now suitable for a wide range of applications, from the accurate quantitative determination of relatively large amounts of known nuclides in laboratory-generated samples to the detection and identification of very small, subpicocurie amounts of alpha emitters in environmental-type samples. Suitable nuclide separation procedures, sample preparation methods, and instrument configurations are outlined for a variety of analyses

  14. Assay of /sup 32/Si by liquid scintillation counting

    Energy Technology Data Exchange (ETDEWEB)

    Cumming, J B [Brookhaven National Lab., Upton, NY (USA)

    1983-10-03

    Application of the radioactivity of /sup 32/Si to problems of interest in geo- and cosmo-chemistry has been hampered by uncertainties in the half-life of this nuclide. A procedure for the stimulation assay of /sup 32/Si and its /sup 32/P daughter utilizing a liquid scintillation detector in association with a pulse height analyzer is described. The results indicate that /sup 32/Si can be assayed to an accuracy of a few percent by liquid scintillation counting techniques which do not require the preparation of an organic Si derivative. Combination of the mean specific activity with the /sup 32/Si abundance determined by accelerator-based mass spectrometry gave the reported 101+-18 year half-life.

  15. Wavelength shifting reflector foils for liquid Ar scintillation light

    Energy Technology Data Exchange (ETDEWEB)

    Walter, Manuel [Physik Institut, Universitaet Zuerich (Switzerland); Collaboration: GERDA-Collaboration

    2013-07-01

    Liquid argon is used as a scintillator in several present and upcoming experiments. In Gerda it is used as a coolant, shielding and will be instrumented to become an active veto in Phase II. Its scintillation light has a wavelength of 128 nm, that gets absorbed by quartz. In order to measure the light using photo multiplier tubes (PMT) for cryogenic temperatures which have a quartz window, it is converted to longer wavelength by coated reflector foils. The conversion efficiency and stability of several such coatings was optimized using VM2000 and Tetratex separately as reflector foils. The efficiency has been measured in a liquid Ar set up build especially for this purpose. It employs a 3'' low radioactivity PMT of type R11065-10 from Hamamatsu, the favorite photo sensor candidate to be used in Gerda.

  16. Optical properties of quantum-dot-doped liquid scintillators

    International Nuclear Information System (INIS)

    Aberle, C; Winslow, L; Li, J J; Weiss, S

    2013-01-01

    Semiconductor nanoparticles (quantum dots) were studied in the context of liquid scintillator development for upcoming neutrino experiments. The unique optical and chemical properties of quantum dots are particularly promising for the use in neutrinoless double-beta decay experiments. Liquid scintillators for large scale neutrino detectors have to meet specific requirements which are reviewed, highlighting the peculiarities of quantum-dot-doping. In this paper, we report results on laboratory-scale measurements of the attenuation length and the fluorescence properties of three commercial quantum dot samples. The results include absorbance and emission stability measurements, improvement in transparency due to filtering of the quantum dot samples, precipitation tests to isolate the quantum dots from solution and energy transfer studies with quantum dots and the fluorophore PPO

  17. SBIR Final Report. Liquid Core Optical Scintillating Fibers

    International Nuclear Information System (INIS)

    Beetz, C.P.; Steinbeck, J.; Buerstler, R.

    2000-01-01

    This Phase I SBIR project focused on developing flexible scintillating liquid core optical fibers, with potential uses in high-energy calorimetry, tracking, preradiators, active targets or other fast detectors. Progress on the six tasks of the project is summarized. The technical developments involve three technology components: (1) highly flexible capillaries or tubes of relatively low n (index of refraction) to serve as cladding and liquid core containment; (2) scintillator (and clear) fluids of relatively high n to serve as a core-- these fluids must have a high light transmission and, for some applications, radiation hardness; (3) optical end plugs, plug insertion, and plug-cladding tube sealing technology to contain the core fluids in the tubes, and to transmit the light

  18. Liquid scintillation: Sample preparation and counting atypical emissions

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    Liquid scintillation sample preparation has the most published information but the least amount of definitive technical direction because the chemical and physical nature of the samples from biological investigations varies widely. This chapter discusses the following related topics: Aqueous Samples; Tissue Solubilizers; Absorption of 14 CO 2 ; Sample Combustion Methods; Heterogeneous Systems; Sample Preparation Problems (colored samples, chemiluminescence, photoluminescence, static electricity); Counting Various Types of Emitters; Counting Atypical Emissions. 2 refs., 2 figs

  19. Direct measurement of tritium in urine by liquid scintillation method

    International Nuclear Information System (INIS)

    Zhang Caihong; Wen Qinghua; Chen Kefei; Li Huaixin

    1999-01-01

    The author introduces the method for direct measurement of tritium concentration in urine using liquid scintillation. Effects of sampling containers, store patterns and storage time are studied. Meanwhile, results of two methods are compared with direct measurement method and oxidation distillation method. The results shows that direct measurement method is a economic and simple method, which can meet the need of determination of urine tritium for NPP workers. There is no significant difference compared with the data obtained by oxidation distillation method

  20. Liquid Scintillation Counting - Packard Triple-Label Calibration

    Energy Technology Data Exchange (ETDEWEB)

    Torretto, P. A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-03-23

    The Radiological Measurements Laboratory (RML) maintains and operates nine Packard Liquid Scintillation Counters (LSCs). These counters were obtained through various sources and were generally purchased as 2500, 2700 or 3100 series counters. In 2004/2005 the software and firmware on the counters were upgraded. The counters are now designated as 3100 series counters running the Quantasmart software package. Thus, a single procedure can be used to calibrate and operate the Packard LSCs.

  1. Standardization of 137 Cs+137m Ba by Liquid Scintillation

    International Nuclear Information System (INIS)

    Rodriguez, L.; Arcos, J.M., los; Grau Carles, A.

    1995-09-01

    A procedure for the preparation of a stable, homogeneous solution of ''137 Cs+''137m Ba, for use in liquid scintillation measurements, is described. Its count rate stability and spectral time evolution has been followed for several weeks. The solution has been standardised by the CIEMAT/NIST method in both Ultima-Gold and Insta-Gel, to a combined uncertainty lower than 0,51% (k=1)

  2. High energy gamma ray response of liquid scintillator

    International Nuclear Information System (INIS)

    Shigyo, N.; Ishibashi, K.; Matsufuji, N.; Nakamoto, T.; Numajiri, M.

    1994-01-01

    We made the experiment on the spallation reaction. NE213 organic liquid scintillators were used for measuring neutrons and γ rays. To produce the γ ray emission cross section, we used the response functions by EGS4 code. The response functions look like uniform above γ ray energies of 60 MeV. The experimental data of the γ ray emission cross section are different from the data of High Energy Transport Code. (author)

  3. Construction and implementation of a liquid scintillation TDCR system

    International Nuclear Information System (INIS)

    Wu Yongle; Liang Juncheng; Liu Jiacheng; Yang Yuandi; Yuan Daqing

    2012-01-01

    The triple-to-double coincidence ratio (TDCR) method is an absolute measurement method of radioactivity, and is a popular technique for the standardization of pure beta radionuclides. A triple-to-double coincidence ratio (TDCR) liquid scintillation counting system has been constructed in China. A description of the system and measured activities for sources such as 3 H and 99 Te are presented. (authors)

  4. Chemical and colour quenching in liquid scintillation counting

    International Nuclear Information System (INIS)

    Scott G, P. E.; Grau M, A.

    1987-01-01

    Chemical and colour quenching for H-3 and C-14 was studied. The method includes spectral analysis of colouring agents; methyl red, (4'-dimethylamine-azobenzene 2-carboxylic acid) dimethyl yellow (4'-dimethylamine-azobenzene) and malachite green (methane, bis .(4-dimethyl aminophenyl) - (phenyl)). External standard channels ratio was applied for the liquid scintillation counting of samples. The introduction of an isolated external standard seems to be a strong tool for the correction of chemical and colour quenching curves. (Author) 12 refs

  5. Alpha/beta separation in liquid scintillation gel samples

    International Nuclear Information System (INIS)

    Grau Carles, A.; Grau Malonda, A.

    1994-01-01

    The pulse shape analysis commonly used in liquid scintillation alpha/beta separations is satisfactory for moderate quench levels. However, for gel samples, the alpha particle counting efficiency is never greater than 10%, and an optimum separation of the alpha component cannot be achieved when beta to alpha counting rate ratios are greater than 100. In such cases, it is better to use a spectrum analysis method for alpha/beta separation. ((orig.))

  6. A large liquid scintillator detector for a long baseline neutrino oscillation experiment

    International Nuclear Information System (INIS)

    Border, P.; Cushman, P.; Heller, K.; Maxam, D.; Nelson, J.K.; Ruddick, K.; Rusack, R.; Schwienhorst, R.; Berg, T.; Chase, T.; Hansen, M.; Bower, C.; Hatcher, R.; Heinz, R.; Miller, L.; Mufson, S.

    2001-01-01

    We present the concept and design of a liquid scintillator detector for a long-baseline neutrino oscillation experiment. Neutrinos interact in 2.5 cm thick steel plates alternating with 2.0 cm thick planes of liquid scintillator. The scintillator is contained in multicell PVC extrusions containing individual 2 cmx3 cm cells up to 8 m long. Readout of the scintillation light is via wavelength-shifting fibers which transport light to pixellated photodetectors at one end of the cells

  7. A Performance Comparison of Nine Selected Liquid Scintillation Cocktails

    Energy Technology Data Exchange (ETDEWEB)

    Verrezen, F; Loots, H; Hurtgen, Ch

    2008-06-15

    In the selection of a suitable liquid scintillation (LSC) cocktail, the primary aspects taken into consideration are overall cocktail performance and specific laboratory needs. Overall performance of 9 selected, commercially available LSC cocktails was assessed by studying parameters of importance for the requirements of the Laboratory for Low Level Radioactivity Measurements of SCK-CEN: sample load capacity, sample compatibility, influence of sample load on counting efficiency, background count rate, figure of merit, quench resistance, sample stability and alpha/beta separation characteristics. The cocktails tested were EcoscintA, Insta Gel Plus, OptiPhase Hisafe3, OptiPhase Trisafe, Ready Gel, SafeScint 1:1, Ultima Gold, Ultima Gold LLT, and Ultima Gold XR. For the data acquisition a Packard TriCarb Model 1900CA and a Quantulus 1220 liquid scintillation counter is used. All samples were prepared in either 20 mL low potassium, borosilicate glass vials or 20 mL high density, polyethylene vials. The aim of this study was to determine a single cocktail that best suits all measurement requirements of the liquid scintillation laboratory at SCK-CEN for the determination of low levels of radioactivity in biological and environmental samples. As a conclusion, Optiphase HiSafe 3 was confirmed to be the optimal cocktail for the laboratory.

  8. A Performance Comparison of Nine Selected Liquid Scintillation Cocktails

    International Nuclear Information System (INIS)

    Verrezen, F.; Loots, H.; Hurtgen, Ch.

    2008-01-01

    In the selection of a suitable liquid scintillation (LSC) cocktail, the primary aspects taken into consideration are overall cocktail performance and specific laboratory needs. Overall performance of 9 selected, commercially available LSC cocktails was assessed by studying parameters of importance for the requirements of the Laboratory for Low Level Radioactivity Measurements of SCK-CEN: sample load capacity, sample compatibility, influence of sample load on counting efficiency, background count rate, figure of merit, quench resistance, sample stability and alpha/beta separation characteristics. The cocktails tested were EcoscintA, Insta Gel Plus, OptiPhase Hisafe3, OptiPhase Trisafe, Ready Gel, SafeScint 1:1, Ultima Gold, Ultima Gold LLT, and Ultima Gold XR. For the data acquisition a Packard TriCarb Model 1900CA and a Quantulus 1220 liquid scintillation counter is used. All samples were prepared in either 20 mL low potassium, borosilicate glass vials or 20 mL high density, polyethylene vials. The aim of this study was to determine a single cocktail that best suits all measurement requirements of the liquid scintillation laboratory at SCK-CEN for the determination of low levels of radioactivity in biological and environmental samples. As a conclusion, Optiphase HiSafe 3 was confirmed to be the optimal cocktail for the laboratory.

  9. Large-Area Liquid Scintillation Detector Slab

    International Nuclear Information System (INIS)

    Crouch, M. F.; Gurr, H. S.; Hruschka, A. A.; Jenkins, T. L.; Kropp, W.; Reines, F.; Sobel, H.; Hruschka, A. A.

    1966-01-01

    A low-cost detector 18' x 2' x 5' has been developed for an underground cosmic ray neutrino experiment. The liquid employed is a high-clarity mineral oil-based mixture, and light is guided to the ends of the detector by total internal reflection at the surface of the Lucite container. Signals from 2 five-inch photomultipliers at each end give energy and event location for single penetrating particles, with relatively good discrimination against natural radioactivity by virtue of the substantial thickness. Data are presented on the response function of the tank, energy resolution, rates and thresholds. A number of modifications that have been tried are also described

  10. Comparison of plastic scintillating fibres and capillaries filled with liquid scintillator

    International Nuclear Information System (INIS)

    Cardini, A.; Cavasinni, V.; Girolamo, B. di; Flaminio, V.; Golovkin, S.V.; Gorin, A.M.; Kulichenko, A.V.; Kushnirenko, A.E.; Pyshev, A.I.; Manuilov, I.; Vasilchenko, V.G.

    1994-01-01

    A comparison is made between the light yield, attenuation length, time response and light propagation speed in plastic scintillating fibres (SCSF-38 and Kuraray-3HF) and quartz capillaries filled with liquid scintillator (LS) 1-methilnaphthalene (1MN) doped with new dyes R45 and R39. The inner diameter of capillaries and diameter of plastic fibres is 0.5 mm. The number of photoelectrons detected at the far end (2 m) was 2.9 for capillaries filled with 1MN+3 g/l R45 while it was 1.8 times smaller in the case of SCSF-38 and 3 times smaller in the case of Kuraray 3HF plastic fibres. Taking into account the quantum efficiency of the photodetector used these reduction factors became 3.0 and 2.0, respectively. Good attenuation length, high light output and also excellent radiation resistance of capillaries filled with LS (>60 Mrad, measured elsewhere) show that they are a very promising alternative to plastic scintillating fibres for future applications in tracking detectors and calorimeters. ((orig.))

  11. Method for determining efficiency in a liquid scintillation system

    International Nuclear Information System (INIS)

    Laney, B.H.

    1975-01-01

    In a liquid scintillation system utilizing plural photomultiplyier means, a method for determining efficiency of coincident pulse detection. Various incremental counting efficiency levels are associated with asymptotic functions in a two dimension matrix in which the abscissa and ordinate correspond to the pulse heights of each of a pair of coincident pulses from different photomultiplier means. An efficiency determining point is located in the matrix based on the sum of the pulse heights of each of the coincident pulses as well as on the amplitude of the smallest pulse of the coincident pulses. The single counting efficiency determining point is recorded as the level of efficiency at which the photomultiplier means detect scintillations that generate coincident pulses having pulse heights equal to those recorded. (Patent Office Record)

  12. Developing Detectors for Scintillation Light in Liquid Argon for DUNE

    Energy Technology Data Exchange (ETDEWEB)

    Howard, Bruce [Fermilab

    2016-12-22

    The Deep Underground Neutrino experiment will conduct a broad program of physics research by studying a beam of neutrinos from Fermilab, atmospheric neutrinos, neutrinos from potential supernovae, and potential nucleon decay events. In pursuit of these studies, the experiment will deploy four 10kt fiducial mass liquid argon time projection chambers underground in Lead, South Dakota. Liquid argon time projection chambers allow high-resolution tracking and energy measurements. A precise timing signal is needed to provide the necessary time stamp to localize events in the drift direction. As liquid argon is a natural scintillator, a photon detection system will be deployed to provide such a signal, especially for non-beam events. In the baseline design for the single-phase time projection chamber, the detectors are contained within the anode plane assemblies. The design of two prototypes utilizing wavelength shifters and light guides are presented, and aspects of the research and development program are discussed.

  13. A study of liquid scintillator and fiber materials for use in a fiber calorimeter

    International Nuclear Information System (INIS)

    Altice, P.P. Jr.

    1990-04-01

    This reports an investigation into the performance of selected scintillation oils and fiber materials to test their applicability in high energy, liquid scintillator calorimetry. Two scintillating oils, Bicron BC-517 and an oil mixed for the MACRO experiment, and two fiber materials, Teflon and GlassClad PS-252, were tested for the following properties: light yield, attenuation length and internal reflection angle. The results of these tests indicated that the scintillation oils and the fiber materials had an overall good performance with lower energies and would meet the requirements of liquid scintillator detection at SSC energies. 6 refs

  14. A liquid scintillator detector for the solar neutrino

    Energy Technology Data Exchange (ETDEWEB)

    Ranucci, G [Lab. Nazionali del Gran Sasso, Assergi (Italy) Massachusetts Inst. of Technology, Cambridge, MA (United States) Joint Inst. for Nuclear Research, Dubna (USSR) Technical Univ. of Munich, Garching (Germany) Physics Dept., Univ. Genova (Italy) INFN, Genova (Italy) Univ. Hawaii, Honolulu, HI (United States) CCR Euratom, Ispra (Italy) Physics Dept., Univ. Milano (Italy) INFN, Milano (Italy) AT and T Bell Lab., Murray Hill, NJ (United States) Physics Dept., Univ. Pavia (Italy) INFN, Pavia (Italy) Physics Dept., Univ. Perugia (Italy) INFN, Perugia (Italy) Drexel Univ., Philadelphia, PA (United States) Charles Univ., Prague (Czechoslovakia) Czech Technical Univ., Prague (Czechoslovakia); Borex Collaboration

    1992-05-01

    Results of the three solar neutrino experiments presently running strongly suggest new neutrino physics scenarios to explain the discrepancy between the expected and measured neutrino flux. New experiments are needed to decide among the several theoretical explanations for this that has become known as the solar neutrino problem. This paper describes the unique features of the proposed low energy solar neutrino detector Borexino, that fully exploiting the powerful handless of liquid scintillation spectroscopy on large scale, will probe emerging suggestions on scenarios invoking neutrino mass mixing and magnetic moment. (orig.).

  15. Chemical and colour quenching in liquid scintillation counting

    International Nuclear Information System (INIS)

    Grau Malonda, A.; Scott Guilleard, P.E.

    1986-01-01

    Chemical and colour quenching for H-3 and C-14 was studied. The method includes spectral analysis of colouring agents; methyl red (4'-dimethylamine-azobenzene 2-carboxilic acid) dimethyl yellow (4'-dimethylamine-azobenzene) and melachite green (metane, bis (4'-dimethyl aminophenyl)-(phenyl)). External standard channels ratio was applied for the liquid scintillation counting of samples. The introduction of an isolated external standard seems to be a strong tool for the correction of chemical and colour quenching curves. (author). 10 figs., 12 refs

  16. Scintillation efficiency of nuclear recoil in liquid xenon

    CERN Document Server

    Arneodo, F; Badertscher, A; Benetti, P; Bernardini, E; Bettini, A; Borio di Tigliole, A A; Brunetti, R; Bueno, A G; Calligarich, E; Campanelli, M; Carpanese, C; Cavalli, D; Cavanna, F; Cennini, P; Centro, Sandro; Cesana, A; Cline, D; De Mitri, I; Dolfini, R; Ferrari, A; Gigli-Berzolari, A; Matthey, C; Mauri, F; Mazza, D; Mazzone, L; Meng, G; Montanari, C; Nurzia, G; Otwinowski, S; Palamara, O; Pascoli, D; Pepato, Adriano; Petrera, S; Periale, L; Piano Mortari, G; Piazzoli, A; Picchi, P; Pietropaolo, F; Rancati, T; Rappoldi, A; Raselli, G L; Rebuzzi, D; Revol, Jean Pierre Charles; Rico, J; Rossella, M; Rossi, C; Rubbia, André; Rubbia, Carlo; Sala, P; Scannicchio, D A; Sergiampietri, F; Suzuki, S; Terrani, M; Tian, W; Ventura, Sandro; Vignoli, C; Wang, H; Woo, J; Xu, Z

    2000-01-01

    We present the results of a test done with a Liquid Xenon (LXe) detector for 'Dark Matter' search, exposed to a neutron beam to produce nuclear recoil events simulating those which would be generated by WIMP's elastic scattering. The aim of the experiment was to measure directly the scintillation efficiency of nuclear recoil. The nuclear recoil considered in the test was in the tens of keV range. The ratio of measured visible energy over the true recoil energy was evaluated to be about 20%, in good agreement with the theoretical predictions.

  17. Stabilization of the photomultiplier gain of a liquid scintillation counter

    International Nuclear Information System (INIS)

    Alkhazov, I.D.; Dmitriev, V.D.; Kuznetsov, A.V.; Malkin, L.Z.; Petrov, B.F.; Sheremet'ev, A.K.; Shpakov, V.I.

    1987-01-01

    A stabilization system of photomultiplier gain, where light-emitting diode flashes have been used to obtain a reference signal, is described. The diode is placed just in the liquid scintilllator volume. The stabilization system contains several (according to the number of photomultipliers) identical channels, which of them consists of a colorimeter, a control trigger and an integrator with an operational amplifier. Increase of photomultiplier stability is reached by changing voltage of photomultiplier power according to the reference signal amplitude. The level of background and efficiency of neutron detection by a scintillation counter are unchanged when using the stabilization system for 10 days of measurements

  18. Optical scattering lengths in large liquid-scintillator neutrino detectors

    Energy Technology Data Exchange (ETDEWEB)

    Wurm, M.; Feilitzsch, F. von; Goeger-Neff, M.; Hofmann, M.; Lewke, T.; Meindl, Q.; Moellenberg, R.; Oberauer, L.; Potzel, W.; Tippmann, M.; Todor, S.; Winter, J. [Physik-Department E15, Technische Universitaet Muenchen, James-Franck-Str., D-85748 Garching (Germany); Lachenmaier, T.; Traunsteiner, C. [Excellence Cluster Universe, Technische Universitaet Muenchen, Boltzmannstr. 2, D-85748 Garching (Germany); Undagoitia, T. Marrodan [Physik-Department E15, Technische Universitaet Muenchen, James-Franck-Str., D-85748 Garching (Germany); Physik-Institut, Universitaet Zuerich, Winterthurstr. 189, CH-8057 Zuerich (Switzerland)

    2010-05-15

    For liquid-scintillator neutrino detectors of kiloton scale, the transparency of the organic solvent is of central importance. The present paper reports on laboratory measurements of the optical scattering lengths of the organic solvents phenylxylylethane, linear alkylbenzene (LAB), and dodecane, which are under discussion for next-generation experiments such as SNO+ (Sudbury Neutrino Observatory), HanoHano, or LENA (Low Energy Neutrino Astronomy). Results comprise the wavelength range of 415-440 nm. The contributions from Rayleigh and Mie scattering as well as from absorption/re-emission processes are discussed. Based on the present results, LAB seems to be the preferred solvent for a large-volume detector.

  19. Optical scattering lengths in large liquid-scintillator neutrino detectors.

    Science.gov (United States)

    Wurm, M; von Feilitzsch, F; Göger-Neff, M; Hofmann, M; Lachenmaier, T; Lewke, T; Marrodán Undagoitia, T; Meindl, Q; Möllenberg, R; Oberauer, L; Potzel, W; Tippmann, M; Todor, S; Traunsteiner, C; Winter, J

    2010-05-01

    For liquid-scintillator neutrino detectors of kiloton scale, the transparency of the organic solvent is of central importance. The present paper reports on laboratory measurements of the optical scattering lengths of the organic solvents phenylxylylethane, linear alkylbenzene (LAB), and dodecane, which are under discussion for next-generation experiments such as SNO+ (Sudbury Neutrino Observatory), HanoHano, or LENA (Low Energy Neutrino Astronomy). Results comprise the wavelength range of 415-440 nm. The contributions from Rayleigh and Mie scattering as well as from absorption/re-emission processes are discussed. Based on the present results, LAB seems to be the preferred solvent for a large-volume detector.

  20. Preparation of 'dead water' for low background liquid scintillation counting

    International Nuclear Information System (INIS)

    Morishima, Hiroshige; Koga, Taeko; Niwa, Takeo; Kawai, Hiroshi

    1987-01-01

    'Dead water', low level tritiated water is indispensable to measure tritium concentration in environmental waters using a low background liquid scintillation counter. Water produced by combustion of natural gas, or deep sea water etc. are usually used for the above purpose. A new method of reducing tritium concentration in natural water has been introduced for preparation of 'dead water'. This method is to combine hydrogen-oxygen mixture produced by water electrolysis with hopcalite catalyzer at 700 deg C. Deep well water was electrolized up to 2/3 volume, and tritium concentration of recombined water was reduced to be about one third of that of the original one. (author)

  1. ARAPUCA a new device for liquid argon scintillation light detection

    International Nuclear Information System (INIS)

    Machado, A.A.; Segreto, E.

    2016-01-01

    We present a totally innovative device for the detection of liquid argon scintillation light, that has been named ARAPUCA (Argon R and D Advanced Program at UniCAmp). It is composed of a passive light collector and of active devices. The latters are standard SiPMs that operate at liquid argon temperature, while the passive collector is based on a new technology, never explored in this field before. It is a photon trap, that allows to collect light with extremely high efficiency. The total detection efficiency of the device can be tuned by modifying the ratio between the area of the active devices (SiPM) and the area of the optical window. For example, it will allow to reach a detection efficiency at the level of 1% on a surface of 50 × 50 cm 2 with an active coverage of 2 × 2 cm 2 (two/three large area SiPM). It is also a cheap device, since the major part of its cost is represented by the active devices. For these reason this appears to be the ideal device for scintillation light detection in large Time Projection Chambers. With appropriate modifications it can be used also in next generation Dark Matter detectors

  2. Low level liquid scintillation analysis for environmental and biomedical quantitation

    International Nuclear Information System (INIS)

    Kessler, M.J.

    1991-01-01

    Over the past five years low level liquid scintillation counting has become increasing popular because of the large number of applications which can be performed using this technique. These applications include environmental monitoring ( 3 H, 90 Sr/ 90 Y, etc.), radiocarbon dating (for age determination to 50,000 years), food adulteration studies (alcohol and beverage industries), radon monitoring (air/water), nuclear power plant monitoring (low level 3 H) and metabolism studies (pharmaceutical research). These applications can be performed with either a dedicated low level LSC or using a standard liquid scintillation counter in conjunction with the new technique of time-resolved LSC (TR-LSC). This technique when used on a standard LSC reduces the instrument background without substantially effecting the background, thus increasing the performance (E 2 /B) of the LSC. Data will be presented for each of the applications mentioned above, comparing the standard LSC and the new TR-LSC techniques. The optimization of the samples for each of these applications will be explored in detail with experimental results. In conclusion, by using the TR-LSC technique in conjunction with a standard LSC the performance of the standard LSC can be increased substantially without dedicating the LSC to doing only low level samples

  3. Cerenkov counting and Cerenkov-scintillation counting with high refractive index organic liquids using a liquid scintillation counter

    Energy Technology Data Exchange (ETDEWEB)

    Wiebe, L I; Helus, F; Maier-Borst, W [Deutsches Krebsforschungszentrum, Heidelberg (Germany, F.R.). Inst. fuer Nuklearmedizin

    1978-06-01

    /sup 18/F and /sup 14/C radioactivity was measured in methyl salicylate (MS), a high refractive index hybrid Cherenkov-scintillation generating medium, using a liquid scintillation counter. At concentrations of up to 21.4%, in MS, dimethyl sulfoxide (DMSO) quenched /sup 14/C fluorescence, and with a 10-fold excess of DMSO over MS, /sup 18/F count rates were reduced below that for DMSO alone, probably as a result of concentration-independent self-quenching due to 'dark-complex' formation. DMSO in lower concentrations did not reduce the counting efficiency of /sup 18/F in MS. Nitrobenzene was a concentration-dependent quencher for both /sup 14/C and /sup 18/F in MS. Chlorobenzene (CB) and DMSO were both found to be weak Cherenkov generators with /sup 18/F. Counting efficiencies for /sup 18/F in MS, CB, and DMSO were 50.3, 7.8 and 4.3% respectively in the coincidence counting mode, and 58.1, 13.0 and 6.8% in the singles mode. /sup 14/C efficiencies were 14.4 and 22.3% for coincidence and singles respectively, and 15.3 and 42.0% using a modern counter designed for coincidence and single photon counting. The high /sup 14/C and /sup 18/F counting efficiency in MS are discussed with respect to excitation mechanism, on the basis of quench and channels ratios changes observed. It is proposed that MS functions as an efficient Cherenkov-scintillation generator for high-energy beta emitters such as /sup 18/F, and as a low-efficiency scintillator for weak beta emitting radionuclides such as /sup 14/C.

  4. Cerenkov counting and Cerenkov-scintillation counting with high refractive index organic liquids using a liquid scintillation counter

    International Nuclear Information System (INIS)

    Wiebe, L.I.; Helus, F.; Maier-Borst, W.

    1978-01-01

    18 F and 14 C radioactivity was measured in methyl salicylate (MS), a high refractive index hybrid Cherenkov-scintillation generating medium, using a liquid scintillation counter. At concentrations of up to 21.4%, in MS, dimethyl sulfoxide (DMSO) quenched 14 C fluorescence, and with a 10-fold excess of DMSO over MS, 18 F count rates were reduced below that for DMSO alone, probably as a result of concentration-independent self-quenching due to 'dark-complex' formation. DMSO in lower concentrations did not reduce the counting efficiency of 18 F in MS. Nitrobenzene was a concentration-dependent quencher for both 14 C and 18 F in MS. Chlorobenzene (CB) and DMSO were both found to be weak Cherenkov generators with 18 F. Counting efficiencies for 18 F in MS, CB, and DMSO were 50.3, 7.8 and 4.3% respectively in the coincidence counting mode, and 58.1, 13.0 and 6.8% in the singles mode. 14 C efficiencies were 14.4 and 22.3% for coincidence and singles respectively, and 15.3 and 42.0% using a modern counter designed for coincidence and single photon counting. The high 14 C and 18 F counting efficiency in MS are discussed with respect to excitation mechanism, on the basis of quench and channels ratios changes observed. It is proposed that MS functions as an efficient Cherenkov-scintillation generator for high-energy beta emitters such as 18 F, and as a low-efficiency scintillator for weak beta emitting radionuclides such as 14 C. (author)

  5. System of the incineration for the liquid scintillation garbage

    International Nuclear Information System (INIS)

    Naba, Katsumi

    1981-12-01

    In Japan from 1980 the incineration of the used scintillation liquid has been permitted according to the safety guide regulation of Japan Scientific Technology Agency. This incineration method would disperse the radioactivity in local site and destroy the chemicals at the same time. This system are consist of three parts. (1) Filtration and pH. adjustment of liquid garbage. (2) Bubbling vaporization in closed cycle. The temperature of the solution inside vessel is kept from 65 0 C to 85 0 C and the solution is bubbled with nealy 4 0 C circulated air. After the end of distillation, water layer is separated from the organic chemical layer and put it down the drain according to the regulation. (3) The residue is mixed with only the distilled organic chemicals according to the next classification, thereafter incineration is carried out. (a) For under the radioactive concentration of 1 x 10 -3 μCi/ml, the mixed scintillation liquid are burned up in specially designed incinerator. (b) For over the level of 1 x 10 -3 μCi/ml, only the distilled organic chemicals are burned up and the residue will be sent to the Waste Disposal Site. (c) For under the water content of 5% these liquid garbage can be directly are burned up without distillation The residue seemed to be suitable for the combustion of the dried carcased animals as the auxiliary fuels. This incinerator will be able to use as room heater or water heater for the bath without radioactive contamination inside of install room. (author)

  6. Liquid scintillation vial for radiometric assay of lymphocyte carbohydrate metabolism in response to mitogens

    International Nuclear Information System (INIS)

    Tran, N.; Wagner, H.N. Jr.

    1978-01-01

    We have demonstrated that mitogens--i.e., PHA and Con.A--stimulate lymphocyte carbohydrate metabolism using a liquid-scintillation vial with conventional liquid-scintillation detectors. The results showed that this enclosed system can be useful for development of rapid in vitro tests of lymphocytes immune responsiveness, as well as for radiometric detection of bacterial growth in various gaseous atmospheres

  7. Scintillation light from cosmic-ray muons in liquid argon

    International Nuclear Information System (INIS)

    Whittington, D.; Howard, B.; Mufson, S.

    2016-01-01

    This paper reports the results of an experiment to directly measure the time-resolved scintillation signal from the passage of cosmic-ray muons through liquid argon. Scintillation light from these muons is of value to studies of weakly-interacting particles in neutrino experiments and dark matter searches. The experiment was carried out at the TallBo dewar facility at Fermilab using prototype light guide detectors and electronics developed for the Deep Underground Neutrino Experiment. Two models are presented for the time structure of the scintillation light, a phenomenological model and a composite model. Both models find τ T  = 1.52 μs for the decay time constant of the Ar 2 * triplet state. These models also show that the identification of the ''early'' light fraction in the phenomenological model, F E  ≈ 25% of the signal, with the total light from singlet decays is an underestimate. The total fraction of singlet light is F S  ≈ 36%, where the increase over F E is from singlet light emitted by the wavelength shifter through processes with long decay constants. The models were further used to compute the experimental particle identification parameter F prompt , the fraction of light coming in a short time window after the trigger compared with the light in the total recorded waveform. The models reproduce quite well the typical experimental value ∼0.3 found by dark matter and double β-decay experiments, which suggests this parameter provides a robust metric for discriminating electrons and muons from more heavily ionizing particles.

  8. Scintillation light from cosmic-ray muons in liquid argon

    Energy Technology Data Exchange (ETDEWEB)

    Whittington, Denver Wade [Indiana Univ., Bloomington, IN (United States). Physics Dept.; Mufson, S. [Indiana Univ., Bloomington, IN (United States). Astronomy Dept.; Howard, B. [Indiana Univ., Bloomington, IN (United States). Physics Dept.

    2016-05-01

    This paper reports the results of an experiment to directly measure the time-resolved scintillation signal from the passage of cosmic-ray muons through liquid argon. Scintillation light from these muons is of value to studies of weakly-interacting particles in neutrino experiments and dark matter searches. The experiment was carried out at the TallBo dewar facility at Fermilab using prototype light guide detectors and electronics developed for the Deep Underground Neutrino Experiment. Two models are presented for the time structure of the scintillation light, a phenomenological model and a physically-motivated model. Both models find tT = 1:52 ms for the decay time constant of the Ar 2 triplet state. These models also show that the identification of the “early” light fraction in the phenomenological model, FE 25% of the signal, with the total light from singlet decays is an underestimate. The total fraction of singlet light is FS 36%, where the increase over FE is from singlet light emitted by the wavelength shifter through processes with long decay constants. The models were further used to compute the experimental particle identification parameter Fprompt, the fraction of light coming in a short time window after the trigger compared with the light in the total recorded waveform. The models reproduce quite well the typical experimental value 0.3 found by dark matter and double b-decay experiments, which suggests this parameter provides a robust metric for discriminating electrons and muons from more heavily ionizing particles.

  9. NEST: a comprehensive model for scintillation yield in liquid xenon

    Energy Technology Data Exchange (ETDEWEB)

    Szydagis, M; Barry, N; Mock, J; Stolp, D; Sweany, M; Tripathi, M; Uvarov, S; Walsh, N; Woods, M [University of California, Davis, One Shields Ave., Davis, CA 95616 (United States); Kazkaz, K, E-mail: mmszydagis@ucdavis.edu [Lawrence Livermore National Laboratory, 7000 East Ave., Livermore, CA 94550 (United States)

    2011-10-15

    A comprehensive model for explaining scintillation yield in liquid xenon is introduced. We unify various definitions of work function which abound in the literature and incorporate all available data on electron recoil scintillation yield. This results in a better understanding of electron recoil, and facilitates an improved description of nuclear recoil. An incident gamma energy range of O(1 keV) to O(1 MeV) and electric fields between 0 and O(10 kV/cm) are incorporated into this heuristic model. We show results from a Geant4 implementation, but because the model has a few free parameters, implementation in any simulation package should be simple. We use a quasi-empirical approach with an objective of improving detector calibrations and performance verification. The model will aid in the design and optimization of future detectors. This model is also easy to extend to other noble elements. In this paper we lay the foundation for an exhaustive simulation code which we call NEST (Noble Element Simulation Technique).

  10. NEST: a comprehensive model for scintillation yield in liquid xenon

    International Nuclear Information System (INIS)

    Szydagis, M; Barry, N; Mock, J; Stolp, D; Sweany, M; Tripathi, M; Uvarov, S; Walsh, N; Woods, M; Kazkaz, K

    2011-01-01

    A comprehensive model for explaining scintillation yield in liquid xenon is introduced. We unify various definitions of work function which abound in the literature and incorporate all available data on electron recoil scintillation yield. This results in a better understanding of electron recoil, and facilitates an improved description of nuclear recoil. An incident gamma energy range of O(1 keV) to O(1 MeV) and electric fields between 0 and O(10 kV/cm) are incorporated into this heuristic model. We show results from a Geant4 implementation, but because the model has a few free parameters, implementation in any simulation package should be simple. We use a quasi-empirical approach with an objective of improving detector calibrations and performance verification. The model will aid in the design and optimization of future detectors. This model is also easy to extend to other noble elements. In this paper we lay the foundation for an exhaustive simulation code which we call NEST (Noble Element Simulation Technique).

  11. Influence of dissolved gas and temperature on the light yield of new liquid scintillators

    CERN Document Server

    Buontempo, S; Golovkin, S V; Martellotti, G; Medvedkov, A M; Penso, G; Soloviev, A S; Vasilchenko, V G

    1999-01-01

    Sixteen new liquid scintillators, emitting green light, were studied. They are based on four solvents combined with four dopants. The influence of different gas atmospheres was studied. In particular it was shown that by keeping these liquid scintillators in vacuum or in a neutral gas, the light yield increases up to 32~\\% at 20 $^{\\circ}$C and for the best solvent-dopant combinations. The dependance of the light yield on temperature was also studied for these scintillators. In the 20--60 $^{\\circ}$C interval, some exhibit a light yield variation of $\\sim$ 3 \\% which is smaller than that of the NE 102A plastic scintillator.

  12. Measurements of 222Rn and 226Ra Levels in environmental samples by using liquid scintillation counter

    International Nuclear Information System (INIS)

    Moustafa, A.S.

    2004-01-01

    The advantageous of liquid scintillation counting technique for 6 Ra determination compared with other methods are the high counting efficiency and the easier sample preparation, with no need for sample pre-concentration. In this work, liquid scintillation counting system was used to measure 222 Rn and 226 Ra levels in environmental samples. The liquid scintillation cocktail was prepared in the laboratory and was found efficient for measuring 222 Rn. Soil, sediment and TENORM samples were dried, grind, sieved and added to hydrochloric acid, in a standard scintillation vial, preloaded with the liquid scintillation cocktail. By measuring 222 Rn levels in the prepared vials, at different intervals of time after preparation, 222 Rn and 226 Ra levels were determined

  13. COOLC, Ne-213 Liquid Scintillation Detector Neutron Spectra Unfolding

    International Nuclear Information System (INIS)

    1971-01-01

    1 - Nature of physical problem solved: COOLC is designed to calculate a neutron energy spectrum from a pulse-height spectrum produced by a detector system using the liquid scintillator NE-213. 2 - Method of solution: The program estimates the counts which would be observed in an ideal detector system having a response which is specified by the user. The solution implicitly takes into account the non-negativity of the desired neutron spectrum. The solution is obtained by finding a nearly optimal combination of slices through the spectrometer response functions such that their sum approximates the response of a channel of the ideal analyzer, and then uses the coefficients so determined to obtain an estimate of the desired neutron spectrum. 3 - Restrictions on the complexity of the problem: There are none noted

  14. Quality assurance manual plutonium liquid scintillation methods and procedures

    International Nuclear Information System (INIS)

    Romero, L.

    1997-01-01

    Nose swipe analysis is a very important tool for Radiation Protection personnel. Nose swipe analysis is a very fast and accurate method for (1) determining if a worker has been exposed to airborne plutonium contamination and (2) Identifying the area where there has been a possible plutonium release. Liquid scintillation analysis techniques have been effectively applied to accurately determine the plutonium alpha activity on nose swipe media. Whatman-40 paper and Q-Tips are the only two media which have been evaluated and can be used for nose swipe analysis. Presently, only Q-Tips are used by Group HSE-1 Radiation Protection Personnel. However, both swipe media will be discussed in this report

  15. The ionization quench factor in liquid-scintillation counting standardizations

    CERN Document Server

    Grau-Malonda, A

    1999-01-01

    We present a new detailed analysis of the ionization quench function Q(E) used in calculating the counting efficiency in liquid-scintillation counting (LSC), which shows that Q(0)=1, and permits one to derive Q(E) as a function of the electron energy and the parameter kB. The coefficients are tabulated by applying a new empirical formula of Q(E) for kB values in the range between 0.001 and 0.20 gMeV sup - sup 1 cm sup - sup 2. We demonstrate the convenience of applying sup 3 H and sup 5 sup 4 Mn for beta-ray and electron capture standardizations, respectively.

  16. LArGe. A liquid argon scintillation veto for GERDA

    International Nuclear Information System (INIS)

    Heisel, Mark

    2011-01-01

    LArGe is a GERDA low-background test facility to study novel background suppression methods in a low-background environment, for possible applications in the GERDA experiment. GERDA searches for the neutrinoless double-beta decay in 76 Ge, by operating naked germanium detectors submersed into 65 m 3 of liquid argon. Similarly, LArGe runs Ge-detectors in 1 m 3 (1.4 tons) of liquid argon, which in addition is instrumented with photomultipliers to detect argon scintillation light. The light is used in anti-coincidence with the germanium detectors, to effectively suppress background events that deposit energy in the liquid argon. This work adresses the design, construction, and commissioning of LArGe. The background suppression efficiency has been studied in combination with a pulse shape discrimination (PSD) technique for various sources, which represent characteristic backgrounds to GERDA. Suppression factors of a few times 10 3 have been achieved. First background data of LArGe (without PSD) yield a background index of (0.12-4.6).10 -2 cts/(keV.kg.y) (90% c.l.), which is at the level of the Gerda phase I design goal. Furthermore, for the first time we measure the natural 42 Ar abundance (in parallel to Gerda), and have indication for the 2νββ-decay in natural germanium. (orig.)

  17. The efficacy of biodegradable liquid scintillation counting cocktails

    International Nuclear Information System (INIS)

    Klein, R.C.; Gershey, E.L.

    1990-01-01

    Liquid scintillation counting (LSC) waste once accounted for ∼50% of the low-level radioactive wastes generated by academic and biomedial research. Strict regulations banning the land burial of organic liquids led the U.S. Nuclear Regulatory Commission to deregulate very low level LSC waste (10CFR20.306 of the Code of Federal Regulations) in 1981. Today, LSC waste containing ≤0.05 μCi/ml of 3 H or 14 C is generally incinerated as flammable liquid. Several manufacturers are now offering cocktails that contain long-chain and multiringed aromatic compounds that have not been identified as hazardous by the Environmental Protection Agency (EPA) under the Resource Conservation and Recovery Act (40CFR261) or the Clean Water Act (40CFR122). In addition to lower toxicity and higher flash points than their predecessors, these new cocktails are being advertised as biodegradable. Simple exclusion from the relatively short EPA lists of hazardous chemicals, however, may only reflect insufficient study. Five cocktail solvent families were identified by gas chromatography (GC) and GC/mass spectrometry: meta- and ortho-xylenes, trimethylbenzene isomers, linear alkylbenzenes, 1-phenyl-1-(3,4-xylyl)-ethane, and diisopropylnaphthalene. Cocktail efficiencies were determined for tritiated samples commonly found in biomedical research by the internal standard method

  18. LArGe. A liquid argon scintillation veto for GERDA

    Energy Technology Data Exchange (ETDEWEB)

    Heisel, Mark

    2011-04-13

    LArGe is a GERDA low-background test facility to study novel background suppression methods in a low-background environment, for possible applications in the GERDA experiment. GERDA searches for the neutrinoless double-beta decay in {sup 76}Ge, by operating naked germanium detectors submersed into 65 m{sup 3} of liquid argon. Similarly, LArGe runs Ge-detectors in 1 m{sup 3} (1.4 tons) of liquid argon, which in addition is instrumented with photomultipliers to detect argon scintillation light. The light is used in anti-coincidence with the germanium detectors, to effectively suppress background events that deposit energy in the liquid argon. This work adresses the design, construction, and commissioning of LArGe. The background suppression efficiency has been studied in combination with a pulse shape discrimination (PSD) technique for various sources, which represent characteristic backgrounds to GERDA. Suppression factors of a few times 10{sup 3} have been achieved. First background data of LArGe (without PSD) yield a background index of (0.12-4.6).10{sup -2} cts/(keV.kg.y) (90% c.l.), which is at the level of the Gerda phase I design goal. Furthermore, for the first time we measure the natural {sup 42}Ar abundance (in parallel to Gerda), and have indication for the 2{nu}{beta}{beta}-decay in natural germanium. (orig.)

  19. Scintillators

    International Nuclear Information System (INIS)

    Cusano, D.A.; Holub, F.F.; Prochazka, S.

    1979-01-01

    Scintillator bodies comprising phosphor materials and having high optical translucency with low light absorption, and methods of making the scintillator bodies, are described. Fabrication methods include (a) a hot-pressing process, (b) cold-pressing followed by sintering, (c) controlled cooling from a melt, and (d) hot-forging. The scintillator bodies that result are easily machined to desired shapes and sizes. Suitable phosphors include BaFCl:Eu, LaOBr:Tb, CsI:Tl, CaWO 4 and CdWO 4 . (U.K.)

  20. Method for calibration measurement in a liquid scintillation counter and carrier used in the method

    International Nuclear Information System (INIS)

    Reunanen, M.A.

    1976-01-01

    The present invention relates to a method for use in liquid scintillation measurements to feed an accurately determined amount of radioactive substance to a fluid scintillation system for a calibration measurement. According to the invention an accurately determined amount of radioactive substance is adsorbed to a carrier, which is introduced into the fluid scintillation system. The invention also relates to a carrier for use in the method

  1. Liquid scintillation systems and apparatus for measuring high-energy radiation emitted by samples in standard laboratory test tubes

    International Nuclear Information System (INIS)

    Benvenutti, R.A.

    1976-01-01

    Liquid scintillation detection system employs improved sample holders in which the cap of a glass vial is provided with a well for receiving a standard laboratory test tube containing a radioactive sample. The well is immersed in a liquid scintillator in the vial, the scintillator containing lead acetate solution to enhance its efficiency. A commercially available beta-counting liquid scintillation apparatus is modified to provide gamma-counting with the improved sample holders

  2. Low energy neutrino astronomy with the large liquid-scintillation detector LENA

    International Nuclear Information System (INIS)

    Undagoitia, T Marrodan; Feilitzsch, F von; Goeger-Neff, M; Hochmuth, K A; Oberauer, L; Potzel, W; Wurm, M

    2006-01-01

    The detection of low energy neutrinos in a large liquid scintillation detector may provide further important information on astrophysical processes as supernova physics, solar physics and elementary particle physics as well as geophysics. In this contribution, a new project for Low Energy Neutrino Astronomy (LENA) consisting of a 50 kt scintillation detector is presented

  3. First results of Minimum Fisher Regularisation as unfolding method for JET NE213 liquid scintillator neutron spectrometry

    International Nuclear Information System (INIS)

    Mlynar, Jan; Adams, John M.; Bertalot, Luciano; Conroy, Sean

    2005-01-01

    At JET, the NE213 liquid scintillator is being validated as a diagnostic tool for spectral measurements of neutrons emitted from the plasma. Neutron spectra have to be unfolded from the measured pulse-height spectra, which is an ill-conditioned problem. Therefore, use of two independent unfolding methods allows for less ambiguity on the interpretation of the data. In parallel to the routine algorithm MAXED based on the Maximum Entropy method, the Minimum Fisher Regularisation (MFR) method has been introduced at JET. The MFR method, known from two-dimensional tomography applications, has proved to provide a new transparent tool to validate the JET neutron spectra measured with the NE213 liquid scintillators. In this article, the MFR method applicable to spectra unfolding is briefly explained. After a mention of MFR tests on phantom spectra experimental neutron spectra are presented that were obtained by applying MFR to NE213 data in selected JET experiments. The results tend to confirm MAXED observations

  4. Partitioning of krypton-85 in liquid scintillation cocktail

    International Nuclear Information System (INIS)

    Hohorst, F.A.; Sherlock, M.A.

    1994-12-01

    Krypton is one of the noble gases. As such, it forms compounds only with exceptionally strong oxidizing agents. The concentration of krypton in air is 1.139 parts per million by volume. In general, its behavior is best described as that of an ideal gas. Krypton-85 is the longest lived of the common radioactive noble gases with a half life of 10.72 years. Gamma radiation at 513.990 keV has an intensity of only 0.434%. Most decay is β - emission with a maximum energy of 687.0 keV and an average energy of 251.4 keV. The analytical chemistry of krypton-85 is driven by these factors. High concentrations may be gamma counted directly. Low levels are typically determined by more sensitive techniques such as liquid scintillation counting (LSC) where detection limits on the order of 1 picocurie (pCi) are routinely achieved. For a 5 standard cubic centimeter (scc) sample, this represents a concentration of 0.2 pCi/scc, well below the DOE Air Immersion Derived Concentration Guideline (G) of 3 pCi/scc. As a gas, krypton in a sealed LSC vial distributes itself between the liquid phase and the gas phase. Some past work has used gamma counting at levels many orders of magnitude greater than those now achievable by LSC to study the distribution of krypton. This effect is of interest in the analytical chemistry of krypton-85 because geometrical considerations influence how much of the material in the gas phase decays generating particles which then impact the liquid phase where they may be counted

  5. Liquid scintillation counting techniques for the determination of some alpha emitting actinides: a review

    International Nuclear Information System (INIS)

    Mirashi, N.N.; Chander, Keshav; Aggarwal, S.K.

    2000-12-01

    The present report is a review of the work on liquid scintillation counting techniques, for the determination of alpha emitting actinides like uranium, plutonium, americium etc; for the last three decades (1970-1999). It covers the progress that has taken place in conventional liquid scintillation counting employing various solvents, scintillators and extractants. There is gradual development in instrumentation from integral counting of alpha emitters to alpha liquid scintillation spectrometry to resolve and identify different alpha emitters. These advancements have led to Pulse Shape Analysis (PSA) and Photon Electron Rejecting Alpha Liquid Scintillation Spectrometry (PERALS) techniques for the determination of the alpha emitters in the presence of beta and gamma activity. These techniques allow the determination of actinides at very low levels which has increased their applications to almost all the fields of chemistry; be it biomedical, environmental, geological or process chemistry of nuclear fuels. The development of biphasic technique using various extractants to separate different elements and counting in presence of one another has been made possible. Inorganic scintillators have been recently developed which have the advantage of eliminating effects of quenching and presence of beta/gamma emitting actinides. This review will serve as a reference to those who want to carry out work in the field of determination of actinides using liquid scintillation counting techniques. (author)

  6. Optimization of cocktail volume in estimation of Tritium activity using liquid scintillation spectrometer

    International Nuclear Information System (INIS)

    Kumaravel, S.; Narashimha Nath, V.; Prashanth Kumar, M.; Sunil, C.N.; Raghunath, T.; Bera, Utpal; Ramakrishna, V.; Nair, B.S.K.; Ganesh, G.; Tripathi, R.M.

    2016-01-01

    Liquid Scintillation Spectrometers (LSS) are widely used for the estimation of Tritium in Nuclear Industry and Environmental labs to find out the Tritium concentration. The main component used for the detection of tritium is the liquid scintillation cocktail composed of different chemicals. To reduce the radioactive chemical wastes and the cost of liquid scintillation cocktails the use of as small volume of cocktail as possible is required. Typically, 1 ml of the aqueous sample is added with 5 ml of the liquid scintillation cocktail in a 20 ml low potassium glass. In this study, suitability of the combination of I ml aqueous sample with 2.5 ml cocktail in a 7 ml low potassium glass vial using a HIDEX 300 SL TDCR LSS was carried out instead of the other combination

  7. Study of absorption and re-emission processes in a ternary liquid scintillation system

    International Nuclear Information System (INIS)

    Xiao Hualin; Wang Naiyan; Li Xiaobo; Cao Jun; Wen Liangjian; Zheng Dong

    2010-01-01

    Liquid scintillators are widely used as the neutrino target in neutrino experiments. The absorption and emission of different components of a ternary liquid scintillator (Linear Alkyl Benzene (LAB) as the solvent, 2, 5-diphenyloxazole (PPO) as the fluor and p-bis-(o-methylstyryl)-benzene (bis-MSB) as wavelength shifter) are studied. It is shown that the absorption of this liquid scintillator is dominant by LAB and PPO at wavelengths less than 349 nm, and the absorption by bis-MSB becomes prevalent at the wavelength larger than 349 nm. The fluorescence quantum yields, which are the key parameters to model the absorption and re-emission processes in large liquid scintillation detectors, are measured. (authors)

  8. Liquid scintillation counting standardization of Na129I by the CIEMAT/NIST method

    International Nuclear Information System (INIS)

    Rodriguez Barquero, L.; Grau Carles, A.; Grau Malonda, A.

    1996-01-01

    We describe a sample preparation procedure for liquid scintillation measurements of stable solution of Na''129I. The counting stability and spectral evolution of this solution is studied in HiSafe''tmII, Ultima-Gold''tm and Insta-Gel''r. The liquid scintillation measurements have been carried efficiencies lower than 0.4%. the solution has been standardized in terms of activity concentration to an overall uncertainty of 0.46% (k=1 )

  9. The Optimum Condition For Determination Of Radioactivity Of Pest Insects Labelled with P-32 By Using Liquid scintillation Counter

    International Nuclear Information System (INIS)

    Yarianto, S.; Susilo, Budi; Sutrisno, Singgih

    2002-01-01

    Tracer technique is needed in the control programe of pest insects especially for determining of its direction and dispersal. Radioisotopes of P-32 is frecuently used for labeling of pest insects. Liquid Scintillation Counter can be used effectively for measuring radioactivity of pest insects labelled by P-32. Optilnization of liquid compositions that consist of solvents. primary scintillation PPO and secondary scintillation POPOP were determined by examination of their compositions. Based on the research result obtained, composition of scintillator which had the highest efficiency. consists of P-Xylene solvent. primary scintillation PPO (5 g/l ) and secondary scintillation POPOP (0.5 g/l)

  10. Method for determination of radon-222 in water by liquid scintillation counting

    International Nuclear Information System (INIS)

    Suomela, J.

    1993-06-01

    The procedure for the determination of radon-222 by liquid scintillation counting is quite specific for this radionuclide. Radon-222 is extracted readily from the water sample by an organic scintillant. The decay products of radon-222 will remain in the water phase whilst radon-222 will be extracted into the organic phase. Before measurement the sample is stored for three hours until equilibrium is reached between radon-222 and its alpha emitting decay products. The alpha activity from radon-222 and its decay products is measured in a liquid scintillation counter

  11. Manual calibration of liquid scintillation counter using the channel ratio technique

    International Nuclear Information System (INIS)

    Moussa, H.M.; Townsend, L.; Miller, L.F.

    1999-01-01

    The objectives of this activity are to introduce students to liquid scintillation counting and to calibrate the counter using the sample channel ratio technique. This is accomplished by using quenched standards set for 14 C and tritium ( 3 H) to generate a quench correction curve for the scintillation solution. It is a good method for students to gain a detailed understanding of issues important to manual calibration of a liquid scintillation counter, and results can be compared with a built-in automatic method

  12. A liquid argon scintillation veto for the GERDA experiment

    Energy Technology Data Exchange (ETDEWEB)

    Wegmann, Anne [Max-Planck-Institut fuer Kernphysik, Saupfercheckweg 1, 69117 Heidelberg (Germany); Collaboration: GERDA-Collaboration

    2014-07-01

    Gerda is an experiment to search for the neutrinoless double beta decay of {sup 76}Ge. Results of Phase I have been published in summer 2013. Currently Gerda is being upgraded to a second phase. To reach the aspired background index of ≤ 10{sup -3} cts/(keV . kg . yr) for Phase II active background-suppression techniques will be applied, including an active liquid argon veto (LAr veto). It has been demonstrated by the LArGe test facility that the detection of argon scintillation light can be used to effectively suppress background events in the germanium, which simultaneously deposit energy in LAr. This talk focusses on the light instrumentation which is being installed in GERDA. Photomultiplier tubes (PMT) and wavelength-shifting fibers connected to silicon photomultipliers (SiPM) are combined to maximize the photoelectron-yield with respect to various background sources. Monte Carlo simulations have been performed to optimize the design for background suppression and low self-induced background. First results of the prototypes and the progress of installation are reported.

  13. Study on efficiency calibration of tritium in liquid scintillation spectrometry

    International Nuclear Information System (INIS)

    Zhai Xiufang; Wang Yaoqin; Li Weiping; Liang Wei; Xu Hui; Zhang Ruirong

    2014-01-01

    The method for efficiency calibration of tritium sample in liquid scintillation spectrometry was presented. The quenching effects from different chemical quenchers (Acidbase, CH_3NO_2, CCl_4, CH_3COCH_3) and color quencher (Na_2CrO_4) were studied. For each quencher, the methods of sample channel ratio (SCR), spectrum index of the sample (SIS) and spectral quenching parameter of the external standard (SQP (E)) were used for efficiency calibration respectively, and three methods were compared. The results show that the quenching from the various chemical quencher can be unified for one chemical quenching for efficiency calibration. There is great difference in the correction curves of chemical quenching and color quenching, and the fact is independent of the used efficiency calibration method. The SCR method is not advantageous for the tritium sample with low radioactivity or strong quenching. The SQP (E) method is independent of the sample count rate, and it is especially suitable for the efficiency calibration of low radioactivity tritium. The SIS method can be used for samples with high radioactivity. The accurate efficiency calibration for various quenching can be carried out by combining the SIS method and the SQP (E) method. (authors)

  14. Strontium-90 (90Sr) determination using liquid scintillation counting

    International Nuclear Information System (INIS)

    Cheberle, L.T.V.; Rosa, M.M.L.; Ferreira, M.T.; Taddei, M.H.T.

    2015-01-01

    This procedure describes a method for separation and measurement of strontium 90 Sr in water, soils, and biological samples. Water samples may be concentrated using evaporation or calcium phosphate coprecipitation. Soils and biological materials must be dissolved using wet digestion. Tracers and carriers must be added before the attack. Radioactive strontium is separated employing a specific resin before determination by liquid scintillation counting using the double energetic window method. The resin is used to concentrate strontium from samples. Stable strontium is used to monitor method yields and correct results to improve precision and accuracy. The presence of elemental strontium in the sample may bias the gravimetric yield determination. If it is suspected that natural strontium is present in the sample, its concentration should be determined by a suitable means (ICP), and the yield calculation properly modified. Sr-Spec resin with an 8M HNO 3 load solution is used to effectively remove 140 Ba and 40 K isotopes, as well as other interferences from the matrix. Tetravalent plutonium, neptunium, cerium and ruthenium, however, are not removed using nitric acid. The radiochemical procedure was tested using PROCORAD intercomparison exercises and PNI samples. (author)

  15. Determination of 90Sr by liquid scintillation counting

    International Nuclear Information System (INIS)

    Cerchetti, Maria L.; Aghazarian, V.P.

    2006-01-01

    99m Tc, the result of the radioactive decay of 99 Mo, is one of the most applied radioisotopes in nuclear medicine and is used in nuclear medicine as a radiopharmaceutical product. It is important to ensure 99 Mo quality in order to fit the 99m Tc quality specifications. The main objective was to obtain a technique for 90 Sr determination in 99 Mo and environmental samples. The purification of 90 Sr is performed by extraction chromatography where crown-ether resin (Sr-Spec, Eichrom) was used. The measurement of the 90 Sr activity is performed by Liquid Scintillation Counting (LSC) using the double windows method. This method permits the 90 Sr determination without waiting until radiochemical equilibrium 90 Sr / 90 Y has been reached. The recovery factor was determined by gamma spectrometry with 85 Sr, and by gravimetry with stable strontium carrier solution. The minimum detectable activity was 0,05 Bq. The recovery factor was the major contribution in the total uncertainty. (author)

  16. Low-level measurements by liquid scintillation counting

    International Nuclear Information System (INIS)

    Schoenhofer, F.

    1991-01-01

    Liquid scintillation counting has become a convenient tool for analysis of many beta- and alpha-emitters even in ultra low-level concentration ranges. Extremely low background is achieved in a commercially available counter by an active shielding and heavy lead shielding. Thus special time saving radiochemical separation processes could be designed. Extremely simple sample preparation techniques can be used. Counting time can be reduced and sample throughput enhanced. Also precision can be enhanced. From the author's research, several applications are discussed. They include: tritium in water without enrichment, tritium in urine (excretion analysis), carbon-14 in samples like alcohol or vinegar, Rn-222 in water and air, even gaseous Kr-85. A simple and fast method for Sr-90 in environmental samples and food has been developed and the Ra-226-concentration in water can be measured as low as 30 mBq/l without any chemical separation or enrichment. The instrument has been used successfully for screening purposes after the Chernobyl accident as well as for monitoring groundwater after a large scale contamination in Lower Austria. Using a 'gross-beta-measurement' effluents from a nuclear installation are monitored, clearly showing advantages over traditional methods. α-β-discrimination reduces the background for alpha emitters to practically zero. Examples from the determination of Ra-226 in water are shown

  17. Liquid scintillation for NORM in the oil and gas industry

    International Nuclear Information System (INIS)

    Moebius, Siegurd; Moebius, Rolf; Bartenbach, Martin; Ramamonjisoa, Tiana

    2008-01-01

    Natural radionuclides of Radium, Lead and Polonium are trapped along with crude oil and gas and accumulate as scale deposits on equipment in the oil industries. Problems arise by residues and sludge where such Norm often becomes concentrated during the process of extraction, transport, and storage of crude oil. Additionally, Radon is accumulated in natural gas or is co extracted into oil as organic phase where it equilibrates with its Progenies. Thus Norm creates a possible hazard to workers both by external radiation exposure and internal due to incorporation during intervention work, and to the environment due to waste disposal. The determination of 222 Rn, 226,228 Ra, 210 Pb, and 210 Po in the various production stages is a precondition for an efficient Radiation Protection Management. We have studied the applicability of Liquid Scintillation L S for the measurement of NORM in the oil and gas industry. Our investigations show that 226 Ra may be quantified by L S in solid scale deposits as carbonate and sulphate after grinding and as carbonate additionally after dissolution. Then, an organic L S scintillation cocktail like Betaplate Scint is added and the sample stored for Rn equilibration. While 222 Rn is quantitatively extracted from the solution, only 20 to 30% are emanated as free Rn from the powder into the organic phase. Emanation yield versus grain size and sample amount has been studied using synthetic Ra/Ca-carbonate powder and grinded Pitchblende ore samples. 226 Ra, 228 Ra and 210 Pb in carbonate may be determined by α/β-discriminating L S after dissolution, mutual separation on Radium Rad Disk filters and final elution with DHC and EDTA. From these results the isotopic ratio of Radium isotopes in the different scale fractions may be determined. 226 Ra, 228 Ra and 210 Pb in production and waste waters may be quantified accordingly. Radon in oil fractions has been measured as 0.1 to 2% solution in Betaplate Scint with sensitivity down to 5 Bq/l. From

  18. Quenching measurements and modeling of a boron-loaded organic liquid scintillator

    Energy Technology Data Exchange (ETDEWEB)

    Westerdale, S.; Xu, J.; Shields, E.; Froborg, F.; Calaprice, F.; Alexander, T.; Aprahamian, A.; Back, H. O.; Casarella, C.; Fang, X.; Gupta, Y. K.; Lamere, E.; Liu, Q.; Lyons, S.; Smith, M.; Tan, W.

    2017-08-01

    Organic liquid scintillators are used in a wide variety of applications in experimental nuclear and particle physics. Boron-loaded scintillators are particularly useful for detecting neutron captures, due to the high thermal neutron capture cross section of $^{10}$B. These scintillators are commonly used in neutron detectors, including the DarkSide-50 neutron veto, where the neutron may produce a signal when it scatters off protons in the scintillator or when it captures on $^{10}$B. Reconstructing the energy of these recoils is complicated by scintillation quenching. Understanding how nuclear recoils are quenched in these scintillators is an important and difficult problem. In this article, we present a set of measurements of neutron-induced proton recoils in a boron-loaded organic liquid scintillator at recoil energies ranging from 57--467 keV, and we compare these measurements to predictions from different quenching models. We find that a modified Birks' model whose denominator is quadratic in $dE/dx$ best describes the measurements, with $\\chi^2$/NDF$=1.6$. This result will help model nuclear recoil scintillation in similar detectors and can be used to improve their neutron tagging efficiency.

  19. Quenching measurements and modeling of a boron-loaded organic liquid scintillator

    International Nuclear Information System (INIS)

    Westerdale, S.; Xu, J.; Shields, E.; Froborg, F.; Calaprice, F.; Alexander, T.; Back, H.O.; Aprahamian, A.; Casarella, C.; Fang, X.; Gupta, Y.K.; Lamere, E.; Liu, Q.; Lyons, S.; Smith, M.; Tan, W.

    2017-01-01

    Organic liquid scintillators are used in a wide variety of applications in experimental nuclear and particle physics. Boron-loaded scintillators are particularly useful for detecting neutron captures, due to the high thermal neutron capture cross section of 10 B. These scintillators are commonly used in neutron detectors, including the DarkSide-50 neutron veto, where the neutron may produce a signal when it scatters off protons in the scintillator or when it captures on 10 B. Reconstructing the energy of these recoils is complicated by scintillation quenching. Understanding how nuclear recoils are quenched in these scintillators is an important and difficult problem. In this article, we present a set of measurements of neutron-induced proton recoils in a boron-loaded organic liquid scintillator at recoil energies ranging from 57–467 keV, and we compare these measurements to predictions from different quenching models. We find that a modified Birks' model whose denominator is quadratic in dE / dx best describes the measurements, with χ 2 /NDF=1.6. This result will help model nuclear recoil scintillation in similar detectors and can be used to improve their neutron tagging efficiency.

  20. Method for measuring multiple scattering corrections between liquid scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Verbeke, J.M., E-mail: verbeke2@llnl.gov; Glenn, A.M., E-mail: glenn22@llnl.gov; Keefer, G.J., E-mail: keefer1@llnl.gov; Wurtz, R.E., E-mail: wurtz1@llnl.gov

    2016-07-21

    A time-of-flight method is proposed to experimentally quantify the fractions of neutrons scattering between scintillators. An array of scintillators is characterized in terms of crosstalk with this method by measuring a californium source, for different neutron energy thresholds. The spectral information recorded by the scintillators can be used to estimate the fractions of neutrons multiple scattering. With the help of a correction to Feynman's point model theory to account for multiple scattering, these fractions can in turn improve the mass reconstruction of fissile materials under investigation.

  1. Determination of plutonium isotopes in bilberry using liquid scintillation spectrometry and alpha-particle spectrometry

    International Nuclear Information System (INIS)

    Seferinoğlu, Meryem; Aslan, Nazife; Kurt, Aylin; Erden, Pınar Esra; Mert, Hülya

    2014-01-01

    This paper presents α-particle spectrometry and liquid scintillation spectrometry methods to determine plutonium isotopes in bilberry. The analytical procedure involves sample preparation steps for ashing, digestion of bilberry samples, radiochemical separation of plutonium radioisotopes and their measurement. The validity of the method was checked for coherence using the ζ test, z-test, relative bias and relative uncertainty outlier tests. The results indicated that the recommended procedures for both measurement systems could be successfully applied for the accurate determination of plutonium activities in bilberry samples. - Highlights: • Sample preparation methods for Pu using LSS and alpha spectrometry developed. • Complete separation of plutonium from interfering radionuclides. • Commercial bilberry was spiked with NPL 2011 (AH-B11144) proficiency test sample. • Results were checked using ζ test, z-test, rel. bias and rel. uncert. outlier tests. • Recommended procedures successfully applied to bilberry samples

  2. A Liquid Scintillator System for Dosimetry of Photon and Proton Beams

    International Nuclear Information System (INIS)

    Beddar S

    2010-01-01

    We have developed a 3D system based on liquid scintillator (LS) for the dosimetry of photon and proton therapy. We have validated the LS detector system for fast and accurate quality assurance of IMRT and proton therapy fields. Further improvements are required to optimize the quantitative analysis of the light output provided by the system in photon beams. We have also demonstrated its usefulness for protons as it can determine the position and the range of proton beams. This system has also been shown to be capable of fast, sub-millimeter spatial localization of proton spots delivered in a 3D volume and could be used for quality assurance of IMPT. Further developments are on-going to measure beam intensities in 3D.

  3. Laboratory studies on the removal of radon-born lead from KamLAND's organic liquid scintillator

    Science.gov (United States)

    Keefer, G.; Grant, C.; Piepke, A.; Ebihara, T.; Ikeda, H.; Kishimoto, Y.; Kibe, Y.; Koseki, Y.; Ogawa, M.; Shirai, J.; Takeuchi, S.; Mauger, C.; Zhang, C.; Schweitzer, G.; Berger, B. E.; Dazeley, S.; Decowski, M. P.; Detwiler, J. A.; Djurcic, Z.; Dwyer, D. A.; Efremenko, Y.; Enomoto, S.; Freedman, S. J.; Fujikawa, B. K.; Furuno, K.; Gando, A.; Gando, Y.; Gratta, G.; Hatakeyama, S.; Heeger, K. M.; Hsu, L.; Ichimura, K.; Inoue, K.; Iwamoto, T.; Kamyshkov, Y.; Karwowski, H. J.; Koga, M.; Kozlov, A.; Lane, C. E.; Learned, J. G.; Maricic, J.; Markoff, D. M.; Matsuno, S.; McKee, D.; McKeown, R. D.; Miletic, T.; Mitsui, T.; Motoki, M.; Nakajima, Kyo; Nakajima, Kyohei; Nakamura, K.; O`Donnell, T.; Ogawa, H.; Piquemal, F.; Ricol, J.-S.; Shimizu, I.; Suekane, F.; Suzuki, A.; Svoboda, R.; Tajima, O.; Takemoto, Y.; Tamae, K.; Tolich, K.; Tornow, W.; Watanabe, Hideki; Watanabe, Hiroko; Winslow, L. A.; Yoshida, S.

    2015-01-01

    The removal of radioactivity from liquid scintillator has been studied in preparation of a low background phase of KamLAND. This paper describes the methods and techniques developed to measure and efficiently extract radon decay products from liquid scintillator. We report the radio-isotope reduction factors obtained when applying various extraction methods. During this study, distillation was identified as the most efficient method for removing radon-born lead from liquid scintillator.

  4. Laboratory studies on the removal of radon-born lead from KamLAND's organic liquid scintillator

    Energy Technology Data Exchange (ETDEWEB)

    Keefer, G., E-mail: gregkeefer@llnl.gov [Department of Physics and Astronomy, University of Alabama, Tuscaloosa, AL 35487 (United States); Grant, C. [Department of Physics and Astronomy, University of Alabama, Tuscaloosa, AL 35487 (United States); Piepke, A. [Department of Physics and Astronomy, University of Alabama, Tuscaloosa, AL 35487 (United States); Kavli Institute for the Physics and Mathematics of the Universe (WPI), University of Tokyo, Kashiwa 277-8583 (Japan); Ebihara, T.; Ikeda, H. [Research Center for Neutrino Science, Tohoku University, Sendai 980-8578 (Japan); Kishimoto, Y. [Research Center for Neutrino Science, Tohoku University, Sendai 980-8578 (Japan); Kavli Institute for the Physics and Mathematics of the Universe (WPI), University of Tokyo, Kashiwa 277-8583 (Japan); Kibe, Y.; Koseki, Y.; Ogawa, M.; Shirai, J.; Takeuchi, S. [Research Center for Neutrino Science, Tohoku University, Sendai 980-8578 (Japan); Mauger, C.; Zhang, C. [W.K. Kellogg Radiation Laboratory, California Institute of Technology, Pasadena, CA 91125 (United States); Schweitzer, G. [Department of Chemistry, University of Tennessee, Knoxville, TN 37996 (United States); Berger, B.E. [Department of Physics, Colorado State University, Fort Collins, CO 80523 (United States); Kavli Institute for the Physics and Mathematics of the Universe (WPI), University of Tokyo, Kashiwa 277-8583 (Japan); Dazeley, S. [Department of Physics and Astronomy, Louisiana State University, Baton Rouge, LA 70803 (United States); Decowski, M.P. [Physics Department, University of California, Berkeley, Berkeley, CA 94720 (United States); Kavli Institute for the Physics and Mathematics of the Universe (WPI), University of Tokyo, Kashiwa 277-8583 (Japan); Detwiler, J.A. [Physics Department, University of California, Berkeley, Berkeley, CA 94720 (United States); Djurcic, Z. [Department of Physics and Astronomy, University of Alabama, Tuscaloosa, AL 35487 (United States); and others

    2015-01-01

    The removal of radioactivity from liquid scintillator has been studied in preparation of a low background phase of KamLAND. This paper describes the methods and techniques developed to measure and efficiently extract radon decay products from liquid scintillator. We report the radio-isotope reduction factors obtained when applying various extraction methods. During this study, distillation was identified as the most efficient method for removing radon-born lead from liquid scintillator.

  5. Analytical method of Kr-85 determination, using cryogenic concentration and separation and liquid scintillation counting

    International Nuclear Information System (INIS)

    Heras Iniquez, M.C.; Perez Garcia, M.M.; Grau Malonda, A.

    1983-01-01

    The method used in the Laboratory of the JEN for the determination of Kr-85 levels in gaseous effluents of nuclear power and in the atmosphere is described. Samples of air, collected in metallic cylinders, are introduced into a gas-solid chromatographic separation system which resolves Kr from the other air components. The separated Kr ia dissolved in a toluene based scintillation cocktail, and the Kr-85 content is determined by liquid scintillation counting. (Author)

  6. Liquid scintillation measurements of aqueous 14C or 3H containing samples in a toluene cocktail

    International Nuclear Information System (INIS)

    Engelmann, A.; Reinhard, G.

    1980-01-01

    On the basis of investigations of the ternary system toluene/methanol/water that composition of toluene/methanol scintillation cocktails has been determined, which allows liquid scintillation measurements of 14 C or 3 H containing samples in homogeneous distribution. Because of more pronounced quenching the optimum sample quantity was less for blood solutions extracted with a HClO 4 /H 2 O 2 mixture than for water. The effect of beta radiation energy has to be taken into account. (author)

  7. Saturation characteristics of liquid rare gas ionization chambers and recombination luminescence in liquid rare gas scintillation

    International Nuclear Information System (INIS)

    Takahashi, Tan; Konno, Satoshi; Kubota, Shinzo; Nakamoto, Jun; Miyajima, Mitsuhiro.

    1978-01-01

    From the saturation characteristics of liquid rare gases (Ar and Xe), the mean distance between electrons and ions. W-value, and the ratio of freely diffusion electrons were determined on the basis of the theory of Onsager. Their relationships with the scintillation due to recombination are also discussed. In the first part of this report, an analytic equation for the probability that an electron escapes from preferential recombination under the existence of an electric field is derived. The equation was then numerically solved with a computer code developed by Freeman. The adjusted parameters and the results of calculations for both Xe and Ar are presented together with the experimental results. Some discrepancy appeared between the analytical and the experimental results when the electric field was weak, and it is ascribable to the existence of the columnar (cluster) recombination and the effect of attachment due to the pulse method employed in the experiments. In the second part, the effect of electric field on the scintillation of liquid rare gases is considered, based on the theory of Onsager. (Aoki, K.)

  8. Liquid scintillation alpha counting and spectrometry and its application to bone and tissue samples

    International Nuclear Information System (INIS)

    McDowell, W.J.; Weiss, J.F.

    1976-01-01

    Three methods for determination of alpha-emitting nuclides using liquid scintillation counting are compared, and the pertinent literature is reviewed. Data showing the application of each method to the measurement of plutonium concentration in tissue and bone samples are presented. Counting with a commercial beta-liquid scintillation counter and an aqueous-phase-accepting scintillator is shown to be accurate only in cases where the alpha activity is high (several hundred counts/min or more), only gross alpha counting is desired, and beta-gamma emitters are known to be absent from the sample or present at low levels compared with the alpha activity. Counting with the same equipment and an aqueous immiscible scintillator containing an extractant for the nuclide of interest (extractive scintillator) is shown to allow better control of alpha peak shift due to quenching, a significant reduction of beta-gamma interference, and, usually, a low background. The desirability of using a multichannel pulse-height analyzer in the above two counting methods is stressed. The use of equipment and procedures designed for alpha liquid scintillation counting is shown to allow alpha spectrometry with an energy resolution capability of 200 to 300 keV full-peak-width-at-half-peak-height and a background of 0.3 to 1.0 counts/min, or as low as 0.01 counts/min if pulse-shape discrimination methods are used. Methods for preparing animal bone and tissue samples for assay are described

  9. Scintillation densimeter for liquids and an isotopic conveyor weighers with plastic scintillator

    International Nuclear Information System (INIS)

    Makhaj, B.; Antonyak, V.; Plyater, Z.

    1979-01-01

    The method is described of the weighted material's mass measuring according to the results of the conveyor momentary load measurement derived from the attenuation of radiation in the transmission geometry, conveyor belt velocity measurement and digital processing of the signals from the measurement of the bouth values. In the measuring gage there are located: the point type gamma source of cesium-137 with 4 mCi capacity, the scintillation detector with plastic cylindric scintillator of 5 cm in diameter and with the length approximately equal to the width of the conveyor belt and also the tachometer-generator. The conveyor weighers described is intended for use with conveyor having belt; from 60 to 180 cm wide. The results are given of industrial exploitation of the instrument [ru

  10. Measuring fast neutrons with large liquid scintillation detector for ultra-low background experiments

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, C. [Department of Physics, The University of South Dakota, Vermillion, SD 57069 (United States); College of Sciences, China Three Gorges University, Yichang 443002 (China); Mei, D.-M., E-mail: dongming.mei@usd.edu [Department of Physics, The University of South Dakota, Vermillion, SD 57069 (United States); Davis, P.; Woltman, B. [Department of Physics, The University of South Dakota, Vermillion, SD 57069 (United States); Gray, F. [Department of Physics and Computational Science, Regis University, Denver, CO 80221 (United States)

    2013-11-21

    We developed a 12-liter volume neutron detector filled with the liquid scintillator EJ301 that measures neutrons in an underground laboratory where dark matter and neutrino experiments are located. The detector target is a cylindrical volume coated on the inside with reflective paint (95% reflectivity) that significantly increases the detector's light collection. We demonstrate several calibration techniques using point sources and cosmic-ray muons for energies up to 20 MeV for this large liquid scintillation detector. Neutron–gamma separation using pulse shape discrimination with a few MeV neutrons to hundreds of MeV neutrons is shown for the first time using a large liquid scintillator.

  11. Timing properties and pulse shape discrimination of LAB-based liquid scintillator

    International Nuclear Information System (INIS)

    Li Xiaobo; Xiao Hualin; Cao Jun; Li Jin; Heng Yuekun; Ruan Xichao

    2011-01-01

    Linear Alkyl Benzene (LAB) is a promising liquid scintillator solvent in neutrino experiments because it has many appealing properties. The timing properties of LAB-based liquid scintillator have been studied through ultraviolet and ionization excitation in this study. The decay time of LAB, PPO and bis-MSB is found to be 48.6 ns, 1.55 ns and 1.5 ns, respectively. A model can describe the absorption and re-emission process between PPO and bis-MSB perfectly. The energy transfer time between LAB and PPO with different concentrations can be obtained via another model. We also show that the LAB-based liquid scintillator has good (n, γ) and (α, γ) discrimination power. (authors)

  12. Measurement of the Rayleigh scattering length in liquid scintillators for JUNO

    Energy Technology Data Exchange (ETDEWEB)

    Hackspacher, Paul [Johannes Gutenberg-Universitaet Mainz, PRISMA Excellence Cluster (Germany); Collaboration: JUNO-Collaboration

    2016-07-01

    In liquid scintillator neutrino detectors such as the upcoming Jiangmen Underground Neutrino Observatory (JUNO), neutrino interactions are being detected by means of inverse beta decay and analysis of the resulting luminescent light. In order to reliably reconstruct these events from photomultiplier signals, the scattering properties of the detector materials need to be sufficiently well known. In the LAB-based liquid scintillator that has been proposed for JUNO, the primary contribution to the scattering process comes from Rayleigh scattering. The characteristic Rayleigh scattering length can be experimentally obtained in an optical laboratory setup. This talk presents the approach, the current status and the future plans of the experiment.

  13. Some studies on extractive liquid scintillation counting for Th-234/P-234m

    International Nuclear Information System (INIS)

    Grudpan, K.; Singjanusong, P.; Punyodom, W.

    1990-01-01

    A study on solvent extraction for Th-234/Pa-234m by liquid scintillation counting has not been reported. This paper will report an application of the technique on such a study. In a hydrochloric acid solution of an uranyl salt, Pa-234m which is one of the daughters of U-238 can be separated by extraction into isobutyl methyl ketone (IBMK). Cerenkov counting was applied for the extraction investigation. Solvent extraction of Th-234/Pa-234m from an aqueous nitric acid solution by TOPO/PPO in toluene by using liquid scintillation counting will be described

  14. Study of the peak shape in alpha spectra measured by liquid scintillation

    CERN Document Server

    Vera-Tome, F; Martin-Sanchez, A

    2002-01-01

    Liquid-scintillation counting allows the measurement of alpha and beta activities jointly or only of the alpha-emitting nuclides in a sample. Although the resolution of the alpha spectra is poorer than that attained with semiconductor detectors, it is still an attractive alternative. We describe here attempts to fit a peak shape to experimental liquid-scintillation alpha spectra and discuss the parameters affecting this shape, such as the PSA (pulse-shape analyser) level, vial type, shaking the sample, etc. Spectral analysis has been applied for complex alpha spectra.

  15. Ionization and scintillation produced by relativistic Au, He and H ions in liquid argon

    Energy Technology Data Exchange (ETDEWEB)

    Shibamura, E; Masuda, K; Crawford, H J; Engelage, J M; Doke, T; Hitachi, A; Kikuchi, J; Flores, I; Lindstrom, P J; Ogura, K

    1987-10-15

    We have measured ionization and scintillation produced by relativistic ions of Au, He and H in liquid argon. The sum of ionization signal and scintillation signal per unit energy deposition is the same for He and H ions, which is also the same as that for relativistic Ne, Fe and La ions previously measured. We have found that quenching occurs when liquid argon is irradiated by relativistic Au ions and that the sum per unit energy deposition for the Au ions is 70-76% of that for the other ions mentioned above.

  16. Liquid scintillation counting of 3H-thymidine incorporated into rat lens DNA

    International Nuclear Information System (INIS)

    Soederberg, P.G.; Lindstroem, B.

    1990-01-01

    DNA synthesis in the lens has previously been localized by autoradiography following incorporation of 3 H-thymidine. For the quantification of DNA synthesis in the lens, pooling of lenses and extraction of the DNA for liquid scintillation counting, has formerly been adapted. In the present investigation a method has been developed for the extraction of the unincorporated tracer from whole lenses after short time incubation in a medium containing 3 H-thymidine. The 3 H-thymidine incorporated into individual lenses was then detected by liquid scintillation counting after dissolution of the lenses. The sources of the variation in the method are evaluated. (author)

  17. Measurement of wavelength-dependent refractive indices of liquid scintillation cocktails

    International Nuclear Information System (INIS)

    Kossert, Karsten

    2013-01-01

    Refractive indices of several commercial liquid scintillation cocktails were measured by means of an automatic critical-angle dispersion refractometer in the wavelength range from 404.7 nm to 706.5 nm. The results are needed for various applications. In particular, detailed Monte Carlo simulations of liquid scintillation counters that include the computation of optical light require these data. In addition, the refractive index is an important parameter for studies of micelle sizes by means of dynamic light scattering. In this work, the refractive indices were determined for Ultima Gold™, Ultima Gold™ F, Ultima Gold™ LLT, Ultima Gold™ AB, Hionic Fluor™, Permafluor ® E+, Mineral Oil Scintillator, Insta-Gel Plus, OptiPhase HiSafe 2, OptiPhase HiSafe 3, Ultima Gold™ XR, Insta-Gel Plus, AquaLight, MaxiLight and Ultima Gold™ MV at 16 °C, 18 °C, 20 °C and 22 °C. The carbon dioxide absorber Carbo-Sorb ® E was also analyzed. For some scintillators, various batches were compared and mixtures with water or nitromethane were studied. - Highlights: • Refractive indices of several liquid scintillation cocktails were measured. • The wavelengths cover a range from 404.7 nm to 706.5 nm. • Measurements were carried out at 16 °C, 18 °C, 20 °C and 22 °C. • For some cocktails, mixtures with water or nitromethane were studied

  18. Removal of actinide elements from liquid scintillation cocktail wastes using liquid-liquid extraction and demulsification techniques

    International Nuclear Information System (INIS)

    Foltz, K.; Landsberger, S.; Srinivasan, B.; Vandegrift, G.F.

    1994-01-01

    For many years liquid scintillation cocktail (LSC) wastes have been generated and stored at Argonne National Laboratory (ANL). These wastes are stored in thousands of 10--20 m scintillation vials, many of which contain elements with Z > 88. Because storage space is limited, disposal of this waste is pressing. These wastes could be commercially incinerated if the radionuclides with Z>88 are reduced to sufficiently low levels. However, there is currently no deminimus level for these radionuclides, and separation techniques are still being tested. The University of Illinois is conducting experiments to separate radionuclides with Z > 88 from simulated LSC wastes by using liquid-liquid extraction (LLX) and demulsification techniques. The actinide elements are removed from the LSC by extraction into an aqueous phase after the cocktail has been demulsified. The aqueous and organic phases are separated and the organic phase, now free from radionuclides with Z > 88, can be sent to a commercial incineration facility. The aqueous phase may be treated and disposed of using existing techniques. The LLX separation techniques used solutions of sodium oxalate, aluminum nitrate, and tetrasodium EDTA at varying concentrations. These extractants were mixed with the simulated waste in a 1:1 volume ratio. Using 1.0M Na 4 EDTA salt solutions, decontamination ratios as high as 230 were achieved

  19. Measurement of radon emanation of drainage layer media by liquid scintillation counting

    International Nuclear Information System (INIS)

    Turtiainen, T.

    2009-01-01

    Slab-on-ground is a typical base floor construction type in Finland. The drainage layer between the slab and soil is a layer of sand, gravel or crushed stone. This layer has a minimum thickness of 200 mm and is sometimes even 600 mm thick, and thus may be a significant contributor to indoor air radon. In order to investigate radon emanation from the drainage layer material, a simple laboratory test was developed. Many organic solvents have high Ostwald coefficients for radon, i.e., the ratio of the volume of gas absorbed to the volume of the absorbing liquid, which enables direct absorption of radon into a liquid scintillation cocktail. Here, we first present equations relating to the processes of gas transfer in emanation measurement by direct absorption into liquid scintillation cocktails. In order to optimize the method for emanation measurement, four liquid scintillation cocktails were assessed for their ability to absorb radon from air. A simple apparatus consisting of a closed glass container holding an open liquid scintillation vial was designed and the diffusion/absorption rate and Ostwald coefficient were determined for a selected cocktail. Finally, a simple test was developed based on this work. (author)

  20. Tritium activity in milk by liquid scintillation counting

    International Nuclear Information System (INIS)

    Zheng Huang

    1993-01-01

    This paper estimates the total tritium content of both the organic and aqueous fractions simultaneously. To fulfill these conditions, the chosen scintillator should be able to accept large sample loadings and display the same counting efficiency for the organic as well as aqueous fractions of the whole milk. In an attempt to establish this method, samples from four different brands of milk were analysed using the pseudocumence based Picofluor 30 (Canberra Packard) and the di-isopropyl naphthalene based Aquasafe 500 (Zinser Analytic) scintillator solution. Glass vials were used thus enabling visual observation to be made. The tritium activities of four different brands of milks were estimated to be very low and at, or near, the detection level of the system

  1. Gamma-Ray interaction probabilities for some liquid scintillators

    International Nuclear Information System (INIS)

    Garcia-Torano Martinez, E.; Grau Malonda, A.

    1989-01-01

    Interaction probabilities for 17 gamma-Ray energies between 1 and 1.000 KeV have been computed and tabulated. The tables may be applied to the case of cylindrical vials with radius 1,25 cm and volumes 5, 10 and 15 ml. Toluene, Toluene/Alcohol, Dioxane-Naftalene, PCS, INSTAGEL and HISAFE II scintillators are considered. Graphical results for 10 ml are also given. (Author)

  2. Estimation of low level gross alpha activities in the radioactive effluent using liquid scintillation counting technique

    International Nuclear Information System (INIS)

    Bhade, Sonali P.D.; Johnson, Bella E.; Singh, Sanjay; Babu, D.A.R.

    2012-01-01

    A technique has been developed for simultaneous measurement of gross alpha and gross beta activity concentration in low level liquid effluent samples in presence of higher activity concentrations of tritium. For this purpose, alpha beta discriminating Pulse Shape Analysis Liquid Scintillation Counting (LSC) technique was used. Main advantages of this technique are easy sample preparation, rapid measurement and higher sensitivity. The calibration methodology for Quantulus1220 LSC based on PSA technique using 241 Am and 90 Sr/ 90 Y as alpha and beta standards respectively was described in detail. LSC technique was validated by measuring alpha and beta activity concentrations in test samples with known amount of 241 Am and 90 Sr/ 90 Y activities spiked in distilled water. The results obtained by LSC technique were compared with conventional planchet counting methods such as ZnS(Ag) and end window GM detectors. The gross alpha and gross beta activity concentrations in spiked samples, obtained by LSC technique were found to be within ±5% of the reference values. (author)

  3. Method for determination of radium-226 in water by liquid scintillation counting

    International Nuclear Information System (INIS)

    Suomela, J.

    1993-07-01

    The chemical procedure involves the isolation or radium from the sample solution by co-precipitation with lead sulphate. The precipitate is dissolved in alkaline DTPA. The radium isotopes are separated from other radionuclides by co-precipitation with barium sulphate. The barium/radium precipitate is dissolved in alkaline EDTA, the solution is transfered to a liquid scintillation vial and the organic scintillant is added. After sealing, the sample is left until equilibrium between Ra-226 and Rn-222 is established or until a suitable ingrowth time has elapsed. The alpha activity of Rn-222 and its short-lived daughters, Po-218 and Po-214, are measured by the use of a commercial liquid scintillation counter. By using the following procedure and a low level LSC a lover limit of detection of 2 mBq/sample can be achieved

  4. Preliminary study of light yield dependence on LAB liquid scintillator composition

    International Nuclear Information System (INIS)

    Ye Xingchen; Yu Boxiang; Zhou Xiang

    2015-01-01

    Liquid scintillator (LS) will be adopted as the detector material in JUNO (Jiangmen Underground Neutrino Observatory). The energy resolution requirement of JUNO is 3%, which has never previously been reached. To achieve this energy resolution, the light yield of liquid scintillator is an important factor. PPO (the fluor) and bis-MSB (the wavelength shifter) are the two main materials dissolved in LAB. To study the influence of these two materials on the transmission of scintillation photons in LS, 25 and 12 cm-long quartz vessels were used in a light yield experiment. LS samples with different concentration of PPO and bis-MSB were tested. At these lengths, the light yield growth is not obvious when the concentration of PPO is higher than 4 g/L. The influence from bis-MSB becomes insignificant when its concentration is higher than 8 mg/L. This result could provide some useful suggestions for the JUNO LS. (authors)

  5. Ionization and scintillation signals produced by relativistic La ions in liquid argon

    Energy Technology Data Exchange (ETDEWEB)

    Crawford, H J; Doke, T; Hitachi, H; Kikuchi, J; Lindstrom, P J; Masuda, K; Shibamura, E; Nagamiya, S

    1987-04-15

    We have observed simultaneously the ionization and scintillation signals produced by relativistic La ions in liquid argon. The two signals are highly correlated and the sums of these signals are constant with the standard deviation of 1.2% over the range of the electric field from 0 to 7.5 kV/cm. The ratio of the sum signals expressed in unit of the number of species to the value N/sub i/ + N/sub ex/ is close to unity where N/sub i/ and N/sub ex/ are the numbers of ion pairs and excitons, respectively, produced by La ions in liquid argon. The pulse height resolution of the sum of the signals is better than that of ionization or scintillation alone. Almost no quenching is found in the scintillation signal from relativistic La ions when compared to signals from lighter ions.

  6. Applications of commercial liquid scintillation counters to radon-222 and radium-226 analyses

    International Nuclear Information System (INIS)

    Gesell, T.F.; Prichard, H.M.; Haygood, J.R.

    1978-01-01

    The ubiquitous commerical liquid scintillation counter offers automatic sample processing, automatic data recording and the prospect of multiple users. With these features in mind we have explored a number of applications of liquid scintillation counters to environmental and health physics problems. One application, the analysis of radon in water has been described elsewhere and is only briefly reviewed. A method for measuring radon in air, two methods for measuring radium in water, and a technique for leak testing radium needles have also been investigated. An ordinary glass scintillation vial is readily converted into a miniature scintillation flask by coating the inside surface with a thin layer in ZnS:Ag phosphor. The lower limit detection is high, about 2 pCi/1 for a 1 hour count, but these flasks have proved to be useful in situations where a larger number of samples must be taken in environments with relatively high levels of radon. One technique for the detection of radium in water uses liquid-liquid extraction to concentrate radon into an organic scintillation fluid, the other involves passing the water sample through an ion exchange resin and then sealing the resin and scintillation fluid in a vial. Both techniques offer the prospect of easy and inexpensive analyses with limits of detection at or below 0.5 pCi/1. Radium needles can be leak tested by placing them in vials containing toluene for a few minutes, adding fluor to the toluene and counting. Preliminary data regarding these several methods are given

  7. Evaluating analytical ionization quenching correction models for 3D liquid organic scintillator detector

    Science.gov (United States)

    Alsanea, F.; Beddar, S.

    2017-05-01

    Proton therapy offers dosimetric advantage over conventional photon therapy due to the finite range of the proton beam, which improves dose conformity. However, one of the main challenges of proton beam therapy is verification of the complex treatment plans delivered to a patient. Thus, 3D measurements are needed to verify the complex dose distribution. A 3D organic scintillator detector is capable of such measurements. However, organic scintillators exhibit a non-linear relation to the ionization density called ionization quenching. The ionization quenching phenomenon in organic scintillators must be accounted for to obtain accurate dose measurements. We investigated the energy deposition by secondary electrons (EDSE) model to explain ionization quenching in 3D liquid organic scintillator when exposed to proton beams. The EDSE model was applied to volumetric scintillation measurement of proton pencil beam with energies of 85.6, 100.9, 144.9 and 161.9 MeV. The quenching parameter in EDSE model ρq was determined by plotting the total light output vs the initial energy of the ion. The results were compared to the Birks semi-empirical formula of scintillation light emission.

  8. A new analytical method for 32P. Liquid scintillation counting with solvent extraction

    International Nuclear Information System (INIS)

    Liyanage, J.A.; Yonezawa, C.

    2003-01-01

    Trace determination of phosphorus has been studied using neutron activation analysis. Radioactivity of 32 P in tri-n-octylamine phosphomolybdate complex was measured using liquid scintillation counting by extracting the complex into xylene. Phosphorus can be quantitatively determined from 16.7 to 600 μg/10 ml by using the radiochemical analysis method described. (author)

  9. Isotope Fractionation in Methane Reactions Studied by Gas Chromatography and Liquid Scintillation

    DEFF Research Database (Denmark)

    Andersen, Bertel Lohmann; Bidoglio, G.; Leip, A.

    1997-01-01

    Determination of C-14-marked methane by gas chromatography and liquid scintillation counting is shown to be useful in studies of isotope effects. Data on the specific activity is used to separate the contributions of (CH4)-C-14, and (CH4)-C-12 to the gas-chromatographic peak area. As an application...

  10. Operation of CdZnTe Semiconductor Detectors in Liquid Scintillator for the COBRA Experiment

    International Nuclear Information System (INIS)

    Oldorf, Christian

    2015-08-01

    COBRA, the Cadmium-Zinc-Telluride O-neutrino double-Beta Research Apparatus, is an experiment aiming for the measurement of the neutrinoless double beta decay with several isotopes, in particular 116 Cd, 106 Cd and 130 Te. A highly granular large scale experiment with about 400 kg of CdZnTe semiconductor detectors is currently under development. To provide evidence for the neutrinoless double beta decay of 116 Cd, a background rate in the order of 10 -3 counts/keV/kg/a is needed to achieve the required half-life sensitivity of at least 2 . 10 26 years. To reach this target, the detectors have to be operated in a highly pure environment, shielded from external radiation. Liquid scintillator is a promising candidate as a circum fluent replacement for the currently used lacquer. Next to the function as highly pure passivation material, liquid scintillator also acts as a neutron shield and active veto for external gammas. Within this thesis, the design, construction and assembly of a test set-up is described. The operation of four CdZnTe detectors after several years of storage in liquid scintillator is demonstrated. Next to extensive material compatibility tests prior to the assembly, the commissioning of the set-up and the characterization of the detectors are shown. Finally, results concerning the background reduction capability of liquid scintillator and the detection of cosmic muons are presented and compared to a Monte Carlo simulation.

  11. Measurement of radon 222 in drinking water and air by liquid scintillation

    International Nuclear Information System (INIS)

    Schoenhofer, F.

    1991-01-01

    This is a brief description of the liquid scintillation measuring method for determining radon 222 in drinking water and air. Discussed are the advantages of this method and its reliability or accuracy, as well as some conclusions from the results. (orig.) [de

  12. Study of alternative methods for the management of liquid scintillation counting wastes

    International Nuclear Information System (INIS)

    Roche-Farmer, L.

    1980-02-01

    The Nuclear Engineering Waste Disposal Site in Richland, Washington, is the only radioactive waste disposal facility that will accept liquid scintillation counting wastes (LSCW) for disposal. That site is scheduled to discontinue receiving LSCW by the end of 1982. This document explores alternatives presently available for management of LSCW: evaporation, distillation, solidification, conversion, and combustion

  13. Determination of /sup 226/Ra by alpha spectrometry of liquid scintillation

    Energy Technology Data Exchange (ETDEWEB)

    Nobrega, A W; Sachett, I A; Hespanhol, E C.B.

    1987-07-01

    The determination of /sup 226/Ra in environmental samples using alpha spectrometry in liquid scintilation is studied. The Radon/sup 1-2/ emanation method and /sup 226/Ra separation process of other radionuclides alpha emissors are analyzed. The use of /sup 226/Ra coprecipitation with barium sulphate is evaluated. (M.J.C.).

  14. Poissonian and binomial models in radionuclide metrology by liquid scintillation counting

    International Nuclear Information System (INIS)

    Grau Malonda, A.

    1990-01-01

    Binomial and Poissonian models developed for calculating the counting efficiency from a free parameter is analysed in this paper. This model have been applied to liquid scintillator counting systems with two or three photomultipliers. It is mathematically demostrated that both models are equivalent and that the counting efficiencies calculated either from one or the other model are identical. (Author)

  15. Liquid scintillator for 2D dosimetry for high-energy photon beams

    International Nuclear Information System (INIS)

    Poenisch, Falk; Archambault, Louis; Briere, Tina Marie; Sahoo, Narayan; Mohan, Radhe; Beddar, Sam; Gillin, Michael T.

    2009-01-01

    Complex radiation therapy techniques require dosimetric verification of treatment planning and delivery. The authors investigated a liquid scintillator (LS) system for application for real-time high-energy photon beam dosimetry. The system was comprised of a transparent acrylic tank filled with liquid scintillating material, an opaque outer tank, and a CCD camera. A series of images was acquired when the tank with liquid scintillator was irradiated with a 6 MV photon beam, and the light data measured with the CCD camera were filtered to correct for scattering of the optical light inside the liquid scintillator. Depth-dose and lateral profiles as well as two-dimensional (2D) dose distributions were found to agree with results from the treatment planning system. Further, the corrected light output was found to be linear with dose, dose rate independent, and is robust for single or multiple acquisitions. The short time needed for image acquisition and processing could make this system ideal for fast verification of the beam characteristics of the treatment machine. This new detector system shows a potential usefulness of the LS for 2D QA.

  16. Liquid scintillator for 2D dosimetry for high-energy photon beams

    Energy Technology Data Exchange (ETDEWEB)

    Poenisch, Falk; Archambault, Louis; Briere, Tina Marie; Sahoo, Narayan; Mohan, Radhe; Beddar, Sam; Gillin, Michael T. [Department of Radiation Physics, University of Texas M. D. Anderson Cancer Center, 1515 Holcombe Boulevard., Unit 94, Houston, Texas 77030 (United States)

    2009-05-15

    Complex radiation therapy techniques require dosimetric verification of treatment planning and delivery. The authors investigated a liquid scintillator (LS) system for application for real-time high-energy photon beam dosimetry. The system was comprised of a transparent acrylic tank filled with liquid scintillating material, an opaque outer tank, and a CCD camera. A series of images was acquired when the tank with liquid scintillator was irradiated with a 6 MV photon beam, and the light data measured with the CCD camera were filtered to correct for scattering of the optical light inside the liquid scintillator. Depth-dose and lateral profiles as well as two-dimensional (2D) dose distributions were found to agree with results from the treatment planning system. Further, the corrected light output was found to be linear with dose, dose rate independent, and is robust for single or multiple acquisitions. The short time needed for image acquisition and processing could make this system ideal for fast verification of the beam characteristics of the treatment machine. This new detector system shows a potential usefulness of the LS for 2D QA.

  17. Determination of the plutonium contamination level in biological samples by liquid scintillation

    International Nuclear Information System (INIS)

    Willemot, J.M.; Verry, M.; Lataillade, G.

    1989-01-01

    Usual radiochemical processes are unable to carry out without delay the very large number of analyses as required in plutonium toxicology studies. Liquid scintillation is the best method to quickly determine plutonium contamination levels in most various samples (bone, organs,...) [fr

  18. Planktonic primary production evaluation by means of the 14C method with liquid scintillation counting

    International Nuclear Information System (INIS)

    Frangopol, T.P.; Bologa, S.A.

    1979-05-01

    Preliminary results on the planktonic primary production obtained for the first time with the 14 C method off the Romanian Black Sea coast (1977, 1978) and in the Sinoe, Mamaia and Bicaz lakes (1978) are presented, along with a review of this method with special reference to liquid scintillation counting. 140 Refs. (author)

  19. Counting efficiency for liquid scintillator systems with a single multiplier phototube

    International Nuclear Information System (INIS)

    Grau Malonda, A.; Garcia-Torano, E.

    1984-01-01

    In this paper counting efficiency as a function of a free parameter (the figure of merit) has been computed. The results are applicable to liquid scintillator systems with a single multiplier phototube. Tables of counting efficiency for 62 pure beta emitters are given for figures of merit in the range 0.25 to 50. (Author) 16 refs

  20. A review of lyoluminescence dosimetry and a new readout method using liquid scintillation techniques

    International Nuclear Information System (INIS)

    Ziemer, P.L.; Hanig, R.; Fayerman, L.K.

    1978-01-01

    Lyoluminescence dosimetry is useful as a personnel monitor and also as a neutron dosimeter. A review of lyoluminescence is given including readout systems, the machanisms of light emission, radiometric characteristics of lyoluminescence dosimeters, factor affecting response and liquid scintillation lyoluminscence readout

  1. Polonium-210 assay using a background-rejecting extractive liquid-scintillation method

    International Nuclear Information System (INIS)

    Case, C.N.; McDowell, W.J.

    1981-01-01

    This paper describes a procedure which combines solvent extraction with alpha liquid scintillation spectrometry. Pulse shape discrimination electronics are used to reject beta and gamma pulses and to lower the background count to acceptable levels. Concentration of 210 Po and separation from interferring elements are accomplished using a H 3 Po 4 -HCl solution with TOPO combined with a scintillor in toluene

  2. Polyethylene vials for liquid scintillation counters produced by the National Materials Research Institute

    International Nuclear Information System (INIS)

    Fiser, B.; Lukas, D.

    1984-01-01

    The properties were tested of polyethylene vials for liquid scintillation counters manufactured by the National Materials Research Institute. Liquid scintillation counter ISOCAP 300 by Nuclear Chicago was used for measuring. For unquenched samples, channel A was set up to 0.5-3.6 keV and channel B to 0.5-18 keV. The scintillation solution was prepared of toluene, 4 g PPO, 0.15 g POPOP per 1 l of toluene. CCl 4 was used as the quenching agent. Radioactive samples were prepared from 20 μl of standard solution of [ 3 H]-toluene with specific activity of 349 Bq/g. All measurements were made using a 7 ml scintillation solution into which radioactivity and possibly quenching agents were added. Potassium-free glass vials by SKLO UNION Teplice and thin-walled polyethylene vials by Nuclear Chicago were used for comparison. The background was measured, as were the time dependences of weight losses of the scintillation solution and carbon tetrachloride from the counting vials, changes in efficiency in channel B with time, changes in SCR with time and changes in the quenching curve with time. (E.S.)

  3. Removal of impurities from environmental water samples for tritium measurement by means of liquid scintillation counter

    International Nuclear Information System (INIS)

    Sakuma, Yoichi; Noda, Mitsuyasu

    2000-01-01

    Tritium concentration in environmental water samples is usually measured by means of liquid scintillation counting. Before the counting distillation operation is necessarily required to remove impurities, which have possibility of bad influence on the measurement, from the samples. But the operation usually takes long time and it is also troublesome. If you could simplify the purification process, you would be much easily able to measure it. Then, we have studied the probability of replacement the process by filtration aiming to simplify the procedure. We prepared several environmental water samples and also several water samples added quenching materials. These samples were purified by means of the distillation and the filtration and the impurities in them were examined. The purified samples were mixed with scintillation cocktail and the tritium concentration was measured. We added small amount of tritium in the same samples and investigated their scintillation spectra and their ESCR values in order to compare the two purification methods. Two kinds of filters were used for the filtration: 0.45 μm and 0.1 μm pore sized membrane filters. The liquid scintillation counter was LB-3 produced by Aloka Co. and Ltd. The scintillation cocktail was Ultima Gold LLT made by Packard Instrument Co and Ltd. The vial was Polyvial 145 LSD made by Zinsser Analytic Co. and Ltd. As the result, there was no significant difference between the two purification methods then the filtration method is feasible instead of the distillation. (author)

  4. Application of avalanche photodiodes for the measurement of actinides by alpha liquid scintillation counting

    International Nuclear Information System (INIS)

    Reboli, A.

    2005-10-01

    Alpha emitters analysis using liquid scintillation spectroscopy is often used when sensitivity and fast samples preparation are the important points. A more extensive use of this technique is until now limited by its poor resolution compared to alpha particle spectroscopy with semiconductor detectors. To improve the resolution and thus promote this method for the measurement of actinides in environment, we have tested silicon avalanche photodiodes (APD) as new detectors for scintillation photons. The set-up consists of a large area avalanche photodiode (16 mm diameter) coupled to a thin vial containing alpha-emitters within a liquid scintillation cocktail. After optimization of several parameters like bias voltage, temperature, counting geometry and composition of the scintillating cocktail, energy resolutions have been found to be better than those obtained with standard photomultiplier tubes (PMT): 5% (200 keV FWHM) for 232 Th and 4.2% (240 keV FWHM) for 236 Pu. Our results show that the improvement is due to less fluctuations associated with light collection since the spatial response of APDs is more uniform than that of PMTs. The expected gain on quantum efficiency (80% for APDs instead of 25% for PMTs) is nullified by a corresponding increase on electronic noise and excess noise factor. Significant better results are foreseen by using green scintillators (450 - 550 nm wavelengths region) with larger Stokes-shift and blue-enhanced APDs which reach their maximum quantum efficiency in this region. (author)

  5. Near-Infrared Scintillation of Liquid Argon: Recent Results Obtained with the NIR Facility at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    Escobar, C. O. [Fermilab; Rubinov, P. [Fermilab; Tilly, E. [Sewanee U.

    2018-03-19

    After a short review of previous attempts to observe and measure the near-infrared scintillation in liquid argon, we present new results obtained with NIR, a dedicated cryostat at the Fermilab Proton Assembly Building (PAB). The new results give confidence that the near-infrared light can be used as the much needed light signal in large liquid argon time projection chambers.11 pages,

  6. Radon determination by activated charcoal adsorption and liquid scintillation measurement

    International Nuclear Information System (INIS)

    Lopez, F.O.; Canoba, A.C.

    1998-01-01

    A passive diffusion method for the determination of radon concentration has been optimised and calibrated. The device consists of a scintillation vial containing activated charcoal, a diffusion barrier and a desiccant agent. The response to diverse atmospheric humidity and variable exposure intervals was studied. The result is a detector, which is independent of atmospheric humidity for at least (up to) 7 days of exposure. The method was compared with electret detectors (US EPA) with very satisfactory results. The advantages of this method are its simplicity, low cost, low detection limit, the total automatization of the measurement and its total independence of humidity to measure in a wide range of radon concentrations. (author) [es

  7. Rapid determination of 226Ra in drinking water samples using dispersive liquid-liquid microextraction coupled with liquid scintillation counting

    International Nuclear Information System (INIS)

    Sadi, B.K.; Chunsheng Li; Kramer, G.H.; Johnson, C.L.; Queenie Ko; Lai, E.P.C.

    2011-01-01

    A new radioanalytical method was developed for rapid determination of 226 Ra in drinking water samples. The method is based on extraction and preconcentration of 226 Ra from a water sample to an organic solvent using a dispersive liquid-liquid microextraction (DLLME) technique followed by radiometric measurement using liquid scintillation counting. In DLLME for 226 Ra, a mixture of an organic extractant (toluene doped with dibenzo-21-crown-7 and 2-theonyltrifluoroacetone) and a disperser solvent (acetonitrile) is rapidly injected into the water sample resulting in the formation of an emulsion. Within the emulsion, 226 Ra reacts with dibenzo-21-crown-7 and 2-theonyltrifluoroacetone and partitions into the fine droplets of toluene. The water/toluene phases were separated by addition of acetonitrile as a de-emulsifier solvent. The toluene phase containing 226 Ra was then measured by liquid scintillation counting. Several parameters were studied to optimize the extraction efficiency of 226 Ra, including water immiscible organic solvent, disperser and de-emulsifier solvent type and their volume, chelating ligands for 226 Ra and their concentrations, inorganic salt additive and its concentration, and equilibrium pH. With the optimized DLLME conditions, the accuracy (expressed as relative bias, B r ) and method repeatability (expressed as relative precision, S B ) were determined by spiking 226 Ra at the maximum acceptable concentration level (0.5 Bq L -1 ) according to the Guidelines for Canadian Drinking Water Quality. Accuracy and repeatability were found to be less than -5% (B r ) and less than 6% (S B ), respectively, for both tap water and bottled natural spring water samples. The minimum detectable activity and sample turnaround time for determination of 226 Ra was 33 mBq L -1 and less than 3 h, respectively. The DLLME technique is selective for extraction of 226 Ra from its decay progenies. (author)

  8. Quenching of liquid scintillator fluorescence by chloroalkanes and chloroalkenes

    International Nuclear Information System (INIS)

    Hariharan, Chithra; Mishra, A.K.

    2000-01-01

    The fluorescence quenching of 2,5-diphenyloxazole (PPO) by a series of chloroalkanes and chloroalkenes including carbon tetrachloride, chloroform, dichloroethane, tetrachloroethane, dichloroethylene, trichloroethylene and tetrachloroethylene was studied in toluene as solvent at room temperature. CCl 4 was found to be the most efficient quencher in the series. The quenching was found to be appreciable and a positive deviation from linearity was observed in the Stern-Volmer (SV) plots for all the quenchers in the concentration range studied. From the studies of effect of temperature, solvent viscosity and excitation wavelength dependence for the PPO-CCl 4 system, it was inferred that non-linearity is due to the presence of a minor static quenching component in an overall dynamic quenching. The static (K S ) and the dynamic (K D ) quenching constants were calculated from the modified SV equation using quadratic least square fits. Fluorescence quenching experiments with CCl 4 were done for four other scintillators (POPOP, α-NPO, BBO and PBBO). The mechanism of quenching was established to be via charge-transfer, with the direction of transfer being from the scintillators to the chloroalkanes and chloroalkenes

  9. Scinfi, a program to calculate the standardization curve in liquid scintillation counting

    International Nuclear Information System (INIS)

    Grau Carles, A.; Grau Malonda, A.

    1984-01-01

    A code, Scinfi, was developed, written in Basic, to compute the efficiency-quench standardization curve for any radionuclide. The program requires the standardization curve for 3 H and the polynomial relations between counting efficiency and figure of merit for both 3 H and the problem (e.g. 14 C). The program is applied to the computation of the efficiency-quench standardization curve for 14 C. Five different liquid scintillation spectrometers and two scintillator solutions have been checked. The computation results are compared with the experimental values obtained with a set of 14 C standardized samples. (author)

  10. Investigation on n/γ discrimination methods for liquid scintillator detector

    International Nuclear Information System (INIS)

    Li Kuinian; Li Yang; Zhang Mei; Zhang Zhongbing; Li Binkang; Zhang Xiaodong; Liu Jun; Zhang Xianpeng

    2014-01-01

    To obtain the n/γ discrimination ability of different digital pulse shape discrimination methods, four methods (rising time method, charge comparison method, pulse gradient analysis and frequency gradient analysis) in americium-beryllium mixed radiation fields were demonstrated. The signals from EJ-301 and BC501A scintillator detectors were digitized using oscilloscope. A comparison was taken among the four discrimination methods. The discrimination results of the four methods in liquid scintillator detectors show that the rising time method is the best and it provides a good choice in real-time n/γ discrimination system. (authors)

  11. Preparation and calibration by liquid scintillation of a sample of Cl 36

    International Nuclear Information System (INIS)

    Grau Malonda, A.; Los Arcos, J.M.; Rodriguez Barquero, L.; Suarez, C.

    1989-01-01

    A procedure to prepare a sample of Clorine 36, as Li 36 Cl, able to be measured by liquid scintillation counting, is described. The sample is chemically stable, with no variation of the quenching parameter up to 4 mg of LiCl per 15 ml of scintillator, keeps constant the counting efficiency for concentration higher than 40 μg of Li 36 Cl in that volume, and shows no deterioration over a 3 weed period. The Li 36 Cl solution has been standarized using the free parameter method with different volumes of toluene, PCS and Instagel, to an uncertainty of 0,3% (Author)

  12. Automation of a Beckman liquid scintillation counter for data capture and data-base management

    International Nuclear Information System (INIS)

    Neil, W.; Irwin, T.J.; Yang, J.J.

    1988-01-01

    A software package for the automation of a Beckman LS9000 liquid scintillation counter is presented. The package provides effective on-line data capture (with a Perkin Elmer 3230 32-bit minicomputer), data-base management, audit trail and archiving facilities. Key features of the package are rapid and flexible data entry, background subtraction, half-life correction, ability to queue several sample sets pending scintillation counting, and formatted report generation. A brief discussion is given on the development of customized data processing programs. (author)

  13. Determination of "1"2"9I using volatilization method and liquid scintillation spectrometry

    International Nuclear Information System (INIS)

    Remenec, Boris; Dulanska, Silvia; Horvathova, Bianka; Matel, Lubomir

    2017-01-01

    A simple and rapid separation method for "1"2"9I determination in radioactive waste samples was developed. Suitable conditions for iodine volatilization were tested. Iodine was trapped in 1.5 mol L"-"1 NaOH and precipitated as PdI_2·H_2O by addition of PdCl_2 with recoveries higher than 80%. The method was applied for analysis of contaminated soil, radioactive sludge, evaporator concentrate and heterogeneous waste samples from nuclear power plants in Slovak Republic. "1"2"9I was measured on liquid scintillation counter TRI CARB 2900 TR using Ultima Gold AB scintillation cocktail. (author)

  14. A new digital method for high precision neutron-gamma discrimination with liquid scintillation detectors

    International Nuclear Information System (INIS)

    Nakhostin, M

    2013-01-01

    A new pulse-shape discrimination algorithm for neutron and gamma (n/γ) discrimination with liquid scintillation detectors has been developed, leading to a considerable improvement of n/γ separation quality. The method is based on triangular pulse shaping which offers a high sensitivity to the shape of input pulses, as well as, excellent noise filtering characteristics. A clear separation of neutrons and γ-rays down to a scintillation light yield of about 65 keVee (electron equivalent energy) with a dynamic range of 45:1 was achieved. The method can potentially operate at high counting rates and is well suited for real-time measurements.

  15. Determination of 226Ra and 224Ra in drinking waters by liquid scintillation counting

    International Nuclear Information System (INIS)

    Manjon, G.; Vioque, I.; Moreno, H.; Garcia-Tenorio, R.; Garcia-Leon, M.

    1997-01-01

    A method for the determination of Ra-isotopes in water samples has been developed. Ra is coprecipitated with Ba as sulphate. The precipitate is then dissolved with EDTA and counted with a liquid scintillation system after mixing with a scintillation cocktail. The study of the temporal evolution of the separated activity gives the isotopic composition of the sample, i.e. the 224 Ra and 226 Ra contribution to the total activity. The method has been applied to some Spanish drinking waters. (author)

  16. Liquid scintillation counting efficiency in three photomultiplier systems. Pure electron capture

    International Nuclear Information System (INIS)

    Los Arcos, J. M.; Grau Carles, A.; Grau Malonda, A.

    1990-01-01

    The tables of counting efficiency as a function of the figure of merit for a liquid scintillation counting system working with three phototubes are presented. The evaluation has been carried out for a Toluene-based scintillator with 5, 10 and 15 ml column, and 19 different radionuclides decaying by pure electron capture: 37Ar 41Ca, 49V, 53 Mn, 55Fe, 59Ni, 68Ge 7iGe, 82Sr, 97Tc, 118Te, 131CS, 137La, 140Ca, 157Tb, 165Er, 193Pt, 194Hg, 205Pb. (Author) 22 refs

  17. Novel determination of protein, fat, and lactose of milk by liquid scintillation counter

    International Nuclear Information System (INIS)

    Noble, R.C.; Shand, J.H.; West, I.G.

    1981-01-01

    A method for routine determination of protein, fat, and lactose contents of milk is based on the ability of a scintillation counter to measure coloration or opalescence through attenuation of photons emitted from sealed miniature carbon-14 and hydrogen-3 radioactive standards. A series of simplified and accurate analytical procedures enable full advantage to be taken of the automatic facilities on the modern liquid scintillation counter. The methods provide several advantages over existing procedures. Accuracy of quantification was high as assessed by comparing the results with those derived by recommended Kjeldahl, Gerber, and colorimetric procedures for protein, fat, and lactose determinations, respectively

  18. SCINFI, a program to calculate the standardization curve in liquid scintillation counting

    International Nuclear Information System (INIS)

    Grau Carles, A.; Grau Malonda, A.

    1984-01-01

    A code, SCINFI, was developed, written in BASIC, to compute the efficiency- quench standardization curve for any radionuclide. The program requires the standardization curve for 3H and the polynomial relations between counting efficiency and figure of merit for both 3H and the problem (e.g. 14 C ). The program is applied to the computation of the efficiency-quench standardization curve for 14 c . Five different liquid scintillation spectrometers and two scintillator solutions have bean checked. The computation results are compared with the experimental values obtained with a set of 14 c standardized samples. (Author)

  19. High-resolution tracking using large capillary bundles filled with liquid scintillator

    CERN Document Server

    Annis, P; Benussi, L; Bruski, N; Buontempo, S; Currat, C; D'Ambrosio, N; Van Dantzig, R; Dupraz, J P; Ereditato, A; Fabre, Jean-Paul; Fanti, V; Feyt, J; Frekers, D; Frenkel, A; Galeazzi, F; Garufi, F; Goldberg, J; Golovkin, S V; Gorin, A M; Grégoire, G; Harrison, K; Höpfner, K; Holtz, K; Konijn, J; Kozarenko, E N; Kreslo, I E; Kushnirenko, A E; Liberti, B; Martellotti, G; Medvedkov, A M; Michel, L; Migliozzi, P; Mommaert, C; Mondardini, M R; Panman, J; Penso, G; Petukhov, Yu P; Rondeshagen, D; Siegmund, W P; Tyukov, V E; Van Beek, G; Vasilchenko, V G; Vilain, P; Visschers, J L; Wilquet, G; Winter, Klaus; Wolff, T; Wörtche, H J; Wong, H; Zimyn, K V

    2000-01-01

    We have developed large high-resolution tracking detectors based on glass capillaries filled with organic liquid scintillator of high refractive index. These liquid-core scintillating optical fibres act simultaneously as detectors of charged particles and as image guides. Track images projected onto the readout end of a capillary bundle are visualized by an optoelectronic chain consisting of a set of image-intensifier tubes followed by a photosensitive CCD or by an EBCCD camera. Two prototype detectors, each composed of \\hbox{$\\approx 10^6$} capillaries with \\hbox{20$-$25 $\\mu$m} diameter and \\hbox{0.9$-$1.8 m} length, have been tested, and a spatial resolution of the order of \\hbox{20$-$40 $\\mu$m} has been attained. A high scintillation efficiency and a large light-attenuation length, in excess of 3 m, was achieved through special purification of the liquid scintillator. Along the tracks of minimum-ionizing particles, the hit densities obtained were $\\sim$ 8 hits/mm at the readout window, and \\hbox{$\\sim$ 3 ...

  20. Evaluation of oxidation techniques for preparing bioassay and environmental samples for liquid scintillation counting

    International Nuclear Information System (INIS)

    Miller, H.H.

    1979-10-01

    In environmental and biological monitoring for carbon-14 and tritium, the presence of color and chemical quenching agents in the samples can degrade the efficiency of liquid scintillation counting. A series of experiments was performed to evaluate the usefulness, under routine conditions, of first oxidizing the samples to improve the counting by removing the color and quenching agents. The scintillation counter was calibrated for the effects of quenching agents on its counting efficiency. Oxidizing apparatus was tested for its ability to accurately recover the 14 C and 3 H in the samples. Scintillation counting efficiences were compared for a variety of oxidized and unoxidized environmental and bioassay samples. The overall conclusion was that, for routine counting, oxidation of such samples is advantageous when they are highly quenched or in solid form

  1. Novel discrimination parameters for neutron-gamma discrimination with liquid scintillation detectors using wavelet transform

    International Nuclear Information System (INIS)

    Singh, H.; Singh, S.

    2015-01-01

    It has been observed that the discrimination performance of the wavelet transform method strongly depends on definition of discrimination parameters. These parameters are usually obtained from a combination of scaling functions at different scales, which represents the energy density of the wavelet coefficients. In this paper, the discrete wavelet transform (DWT) at minimum possible values of scale was investigated. Novel pulse shape discrimination parameters have been proposed for neutron and gamma discrimination in a mixed radiation field and tested with modeled pulses. The performance of these parameters was also validated in terms of quality of discrimination using experimental data of mixed events from an AmBe source collected with BC501 liquid scintillation detector. The quality of discrimination was evaluated by calculating a figure of merit (FOM) with all parameters under same experimental and simulation conditions. The FOM obtained with the proposed novel parameters was also compared with the charge comparison method. The proposed parameters exhibit better FOM as compared to the charge comparison method when high levels of noise are present in the data

  2. Comparison of analysis techniques by liquid scintillation and Cerenkov Effect for 40K quantification in aqueous samples

    International Nuclear Information System (INIS)

    Miranda C, L.; Davila R, J. I.; Lopez del R, H.; Mireles G, F.

    2015-09-01

    In this work the counting by liquid scintillation and Cerenkov Effect to quantify 40 K in aqueous samples was used. The performance of both techniques was studied by comparing the response of three commercial liquid scintillation OptiPhase HiSafe 3, Ultima Gold Ab and OptiPhase TriSafe, the vial type and presentation conditions of the sample for counting. In liquid scintillation, the ability to form homogeneous mixtures depended on the ionic strength of the aqueous solutions. The scintillator OptiPhase HiSafe 3 showed a greater charge capacity for solutions with high ionic strength (<3.4), while the scintillator OptiSafe TriSafe no form homogeneous mixtures for solutions of ionic strength higher than 0.3. Counting efficiencies for different proportions of sample and scintillator near 100% for the scintillators OptiSafe HiSafe 3 and Ultima Gold Ab were obtained. In the counting by Cerenkov Effect, the efficiency and sensitivity depended of the vial type; polyethylene vials were more suitable for counting that the glass vials. The sample volume had not significant effect on counting efficiency, obtaining an average value of 44.8% for polyethylene vials and 37.3% for glass vials. Therefore, the liquid scintillation was more efficient and sensitive for the measurement of 40 K in aqueous solutions. (Author)

  3. Liquid organic scintillator in a polymerizable emulsion, its application to radioactive counting and process for its destruction

    International Nuclear Information System (INIS)

    O'Brien, R.E.; Krieger, J.K.

    1981-01-01

    Scintillation organic liquid mixture for performing very efficient counts on compound solutions labelled with a radioactive indicator containing up to 10% water by volume and which is easily polymerizable into a solid substance, in order to facilitate its elimination. The mixture includes a polymerizable organic solvent, a solubilizing agent, an intermediate solvent and an organic scintillator [fr

  4. Detection of supernova neutrinos in the liquid-scintillator experiment LENA

    International Nuclear Information System (INIS)

    Winter, Jurgen Michael Albrecht

    2014-01-01

    The LENA project (Low-Energy Neutrino Astronomy) is a planned large-volume liquid-scintillator detector. The good energy resolution, low-energy threshold, and its large mass allow to perform real-time spectroscopy of low-energy neutrinos with high statistics. This is especially beneficial for the observation of rare events such as a galactic core-collapse supernova. In a liquid scintillator, interactions by different particle types cause different scintillation light pulse shapes. They can be used to identify proton recoils induced by neutrino-proton scattering from supernova neutrinos or by cosmogenic knock-out neutrons. In order to evaluate the performance of the detector, a precise characterization of the liquid scintillator is necessary. In the course of this work, an experiment has been set up at the Maier-Leibnitz-Laboratorium in Garching in order to determine the pulse shape of proton and electron recoils in different liquid-scintillator mixtures. Neutrons produced via 11 B(p,n) 11 C or an americiumberyllium source were used to induce proton recoils. Compton scattering of simultaneously emitted γs provided information on the electron recoils. A time-of-flight measurement allows for an easy identification of neutron and γ induced events and thus effective background reduction. The tail-to-total and the Gatti method are used in order to determine the energy-dependent discrimination power of proton and electron recoils in liquid scintillator. Combining both methods, a proton recoil identification efficiency of (99.70±0.05)% can be achieved between 1-1.5 MeV, while suppressing 99% of the γ induced recoils for the probable liquid scintillator mixture for LENA, linear alkylbenzene (LAB) as solvent and 3 g/l 2,5-diphenyloxazole (PPO) and 20mg/l 1,4-bis-(o-methylstyryl)-benzole (bisMSB) as fluors. Moreover, the decay constants τ i and the respective amplitudes n i are determined for various liquid scintillator mixtures. It can be observed that the decay times

  5. Test use of 'Ready Cap' for radiation measurement with a liquid scintillation counter

    International Nuclear Information System (INIS)

    Kato, Takahisa; Saito, Kazumi; Kurihara, Norio

    1989-01-01

    We tested the performance of 'Ready Cap' which can be used in place of liquid scintillation cocktails to measure the activity of 3 H and 14 C with a liquid scintillation counter, and observed satisfactory results on counting efficiencies for these nuclides. We could correct color-quenching with Ready Cap either by a method of the gravity-center of β-ray spectrum or by an external standard method that uses the external irradiation from bottom of the sample. Although there are several problems such as limitation of the maximum sample volumes (<200 μl) and sample preparation procedures (drying the sample solution), we can conveniently employ Ready Cap in some aspects of activity counting because of the easy disposal procedure of the radioactive waste resulting from it. (author)

  6. Fitting of alpha-efficiency versus quenching parameter by exponential functions in liquid scintillation counting

    International Nuclear Information System (INIS)

    Sosa, M.; Manjón, G.; Mantero, J.; García-Tenorio, R.

    2014-01-01

    The objective of this work is to propose an exponential fit for the low alpha-counting efficiency as a function of a sample quenching parameter using a Quantulus liquid scintillation counter. The sample quenching parameter in a Quantulus is the Spectral Quench Parameter of the External Standard (SQP(E)), which is defined as the number of channel under which lies the 99% of Compton spectrum generated by a gamma emitter ( 152 Eu). Although in the literature one usually finds a polynomial fitting of the alpha counting efficiency, it is shown here that an exponential function is a better description. - Highlights: • We have studied the quenching in alpha measurement by liquid scintillation counting. • We have reviewed typical fitting of alpha counting efficiency versus quenching parameter. • Exponential fitting of data is proposed as better fitting. • We consider exponential fitting has a physical basis

  7. Fitting of alpha-efficiency versus quenching parameter by exponential functions in liquid scintillation counting

    Energy Technology Data Exchange (ETDEWEB)

    Sosa, M. [Departamento de Ingeniería Física, Campus León, Universidad de Guanajuato, 37150 León, Guanajuato (Mexico); Universidad de Sevilla, Departamento de Física Aplicada II, E.T.S. Arquitectura, Av. Reina Mercedes, 2, 41012 Sevilla (Spain); Manjón, G., E-mail: manjon@us.es [Universidad de Sevilla, Departamento de Física Aplicada II, E.T.S. Arquitectura, Av. Reina Mercedes, 2, 41012 Sevilla (Spain); Mantero, J.; García-Tenorio, R. [Universidad de Sevilla, Departamento de Física Aplicada II, E.T.S. Arquitectura, Av. Reina Mercedes, 2, 41012 Sevilla (Spain)

    2014-05-01

    The objective of this work is to propose an exponential fit for the low alpha-counting efficiency as a function of a sample quenching parameter using a Quantulus liquid scintillation counter. The sample quenching parameter in a Quantulus is the Spectral Quench Parameter of the External Standard (SQP(E)), which is defined as the number of channel under which lies the 99% of Compton spectrum generated by a gamma emitter ({sup 152}Eu). Although in the literature one usually finds a polynomial fitting of the alpha counting efficiency, it is shown here that an exponential function is a better description. - Highlights: • We have studied the quenching in alpha measurement by liquid scintillation counting. • We have reviewed typical fitting of alpha counting efficiency versus quenching parameter. • Exponential fitting of data is proposed as better fitting. • We consider exponential fitting has a physical basis.

  8. Performance of a prototype active veto system using liquid scintillator for a dark matter search experiment

    Energy Technology Data Exchange (ETDEWEB)

    Park, J.S. [Center for Underground Physics, Institute for Basic Science (IBS), Daejeon 34047 (Korea, Republic of); Adhikari, P.; Adhikari, G.; Oh, S.Y. [Department of Physics, Sejong University, Seoul 05006 (Korea, Republic of); Kim, N.Y. [Center for Underground Physics, Institute for Basic Science (IBS), Daejeon 34047 (Korea, Republic of); Kim, Y.D. [Center for Underground Physics, Institute for Basic Science (IBS), Daejeon 34047 (Korea, Republic of); Department of Physics, Sejong University, Seoul 05006 (Korea, Republic of); Ha, C.; Park, K.S. [Center for Underground Physics, Institute for Basic Science (IBS), Daejeon 34047 (Korea, Republic of); Lee, H.S., E-mail: hyunsulee@ibs.re.kr [Center for Underground Physics, Institute for Basic Science (IBS), Daejeon 34047 (Korea, Republic of); Jeon, E.J. [Center for Underground Physics, Institute for Basic Science (IBS), Daejeon 34047 (Korea, Republic of)

    2017-04-11

    We report the performance of an active veto system using a liquid scintillator with NaI(Tl) crystals for use in a dark matter search experiment. When a NaI(Tl) crystal is immersed in the prototype detector, the detector tags 48% of the internal {sup 40}K background in the 0–10 keV energy region. We also determined the tagging efficiency for events at 6–20 keV as 26.5±1.7% of the total events, which corresponds to 0.76±0.04 events/keV/kg/day. According to a simulation, approximately 60% of the background events from U, Th, and K radioisotopes in photomultiplier tubes are tagged at energies of 0–10 keV. Full shielding with a 40-cm-thick liquid scintillator can increase the tagging efficiency for both the internal {sup 40}K and external background to approximately 80%.

  9. Optimization of liquid scintillation measurements applied to smears and aqueous samples collected in industrial environments

    Directory of Open Access Journals (Sweden)

    Arnaud Chapon

    Full Text Available Search for low-energy β contaminations in industrial environments requires using Liquid Scintillation Counting. This indirect measurement method supposes a fine control from sampling to measurement itself. Thus, in this paper, we focus on the definition of a measurement method, as generic as possible, for both smears and aqueous samples’ characterization. That includes choice of consumables, sampling methods, optimization of counting parameters and definition of energy windows, using the maximization of a Figure of Merit. Detection limits are then calculated considering these optimized parameters. For this purpose, we used PerkinElmer Tri-Carb counters. Nevertheless, except those relative to some parameters specific to PerkinElmer, most of the results presented here can be extended to other counters. Keywords: Liquid Scintillation Counting (LSC, PerkinElmer, Tri-Carb, Smear, Swipe

  10. The effect of volume and quenching on estimation of counting efficiencies in liquid scintillation counting

    International Nuclear Information System (INIS)

    Knoche, H.W.; Parkhurst, A.M.; Tam, S.W.

    1979-01-01

    The effect of volume on the liquid scintillation counting performance of 14 C-samples has been investigated. A decrease in counting efficiency was observed for samples with volumes below about 6 ml and those above about 18 ml when unquenched samples were assayed. Two quench-correction methods, sample channels ratio and external standard channels ratio, and three different liquid scintillation counters, were used in an investigation to determine the magnitude of the error in predicting counting efficiencies when small volume samples (2 ml) with different levels of quenching were assayed. The 2 ml samples exhibited slightly greater standard deviations of the difference between predicted and determined counting efficiencies than did 15 ml samples. Nevertheless, the magnitude of the errors indicate that if the sample channels ratio method of quench correction is employed, 2 ml samples may be counted in conventional counting vials with little loss in counting precision. (author)

  11. The IFIN-HH triple coincidence liquid scintillation counter

    CSIR Research Space (South Africa)

    Razdolescu, AC

    2006-10-01

    Full Text Available at IFIN-HH using a 3 H standard. The performances of the IFIN-HH TDCR counter was checked against the measurement results of the TDCR counters of CSIR NML (South Africa), RC (Poland) and LNHB (France). A set of ready-to-measure Ni-63 sources in liquid...

  12. Some applications of Photon/Electron-Rejecting Alpha Liquid Scintillation (PERALS) spectrometry to the assay of alpha emitters

    International Nuclear Information System (INIS)

    McDowell, W.J.; Case, G.N.

    1988-01-01

    The combination of certain solvent extraction separations and a special kind of liquid scintillation detector and electronics designed for alpha spectrometry allows some highly accurate, yet simple determinations of alpha-emitting nuclides. Counting efficiency is 99.68% with backgrounds of 99.95%. The Photon/Electron Rejecting Alpha Liquid Scintillation (PERALS) equipment is described and procedures for the separation and determination of uranium, thorium, plutonium, polonium, radium, and trivalent actinides are outlined. 25 refs., 10 figs., 1 tab

  13. Standardization of iodine-129 by the TDCR liquid scintillation method and 4π β-γ coincidence counting

    Science.gov (United States)

    Cassette, P.; Bouchard, J.; Chauvenet, B.

    1994-01-01

    Iodine-129 is a long-lived fission product, with physical and chemical properties that make it a good candidate for evaluating the environmental impact of the nuclear energy fuel cycle. To avoid solid source preparation problems, liquid scintillation has been used to standardize this nuclide for a EUROMET intercomparison. Two methods were used to measure the iodine-129 activity: triple-to-double-coincidence ratio liquid scintillation counting and 4π β-γ coincidence counting; the results are in good agreement.

  14. Determination of carbon-14 environmental samples by mixing 14CO2 with a liquid scintillator

    International Nuclear Information System (INIS)

    Garcia Sanz, M.R.; Gomez, V.; Heras, M.C.; Beltran, M.A.

    1990-01-01

    A method for the determination of Carbon-14 ( 14 CO 2 ) in environmental samples has been developed. The method use the direct absorption of the carbon dioxide into Carbosorb, followed with incorporation of the mixture (Carbosorb-CO 2 ) to the liquid scintillator. The results obtained to apply this method and the benzene synthesis, usual in our laboratory, are discused and compared. The method of collection of atmospheric samples is also described. (Author)

  15. The research program of the Liquid Scintillation Detector (LSD) in the Mont Blanc Laboratory

    Science.gov (United States)

    Dadykin, V. L.; Yakushev, V. F.; Korchagin, P. V.; Korchagin, V. B.; Malgin, A. S.; Ryassny, F. G.; Ryazhskaya, O. G.; Talochkin, V. P.; Zatsepin, G. T.; Badino, G.

    1985-01-01

    A massive (90 tons) liquid scintillation detector (LSD) has been running since October 1984 in the Mont Blanc Laboratory at a depth of 5,200 hg/sq cm of standard rock. The research program of the experiment covers a variety of topics in particle physics and astrophysics. The performance of the detector, the main fields of research are presented and the preliminary results are discussed.

  16. Efficiency calibration of a liquid scintillation counter for 90Y Cherenkov counting

    International Nuclear Information System (INIS)

    Vaca, F.; Garcia-Leon, M.

    1998-01-01

    In this paper a complete and self-consistent method for 90 Sr determination in environmental samples is presented. It is based on the Cherenkov counting of 90 Y with a conventional liquid scintillation counter. The effects of color quenching on the counting efficiency and background are carefully studied. A working curve is presented which allows to quantify the correction in the counting efficiency depending on the color quenching strength. (orig.)

  17. Standardization of 40 K by liquid scintillation counting. Determination of the half-life

    International Nuclear Information System (INIS)

    Grau Carles, A.; Grau Malonda, A.

    1997-01-01

    The relative abundance of the natural radioisotope ''40 K in environmental samples frequently generates interferences in low activity measurements. In the present study we propose the determination of ''40 K by the CIEMAT/NIST method. On this context, the verification of ''40 K half-life is required. We present a half-life value obtained by liquid scintillation counting in excellent agreement with those reported in the literature. (Author)

  18. Standardization of 137mCs+137mBa by Liquid Scintillation

    International Nuclear Information System (INIS)

    Rodriguez, L.; Los Arcos, J.M.; Grau, A.

    1995-01-01

    A procedure for the preparation of a stable, homogeneous solution of 137Cs+''137mBa, for use in liquid scintillation measurements, is described. Its count rate stability and spectral time evolution has been followed for several weeks. The solution has been standardised by the CIEMAT/NIST method in both Ultima-Gold and Insta-Gel, to a combined uncertainty lower than 0,51 % (k=l). (Author) 5 refs

  19. Determination of Carbon-14 in environmental samples by mixing 14CO2 with a liquid scintillator

    International Nuclear Information System (INIS)

    Garcia, M. R.; Gomez, V.; Heras, M. C.; Beltran, M. A.

    1990-01-01

    A method for the determination of Carbon-14 (14CO2) in environmental samples has been developed. The method use the direct absorption of the carbon dioxide into Carbosorb, followed with incorporation of the mixture (Carbosorb-CO2) to the liquid scintillator. The results obtained to apply this method and the benzene synthesis, usual in our laboratory, are discussed and compared. The method of collection of atmospheric samples is also described. (Author) 10 refs

  20. Liquid Scintillation counting Standardization of 22 NaCl by the CIEMAT/NIST method

    International Nuclear Information System (INIS)

    Rodriguez Barquero, L.; Grau Carles, A.; Grau Malonda, A.

    1995-09-01

    We describe a procedure for preparing a stable solution of ''22 NaCl for liquid scintillation counting and its counting stability and spectral evolution in Insta-Gel''R is studied. The solution has been standardised in terms of activity concentration by the CIEMAT/NIST method with discrepancies between experimental and computed efficiencies lower than 0.4/% and an overall uncertainty of 0.35%

  1. Liquid Scintillation Counting Standardization of 22NaCl by te CIEMAT/NIST method

    International Nuclear Information System (INIS)

    Rodriguez Barquero, L.; Grau Carles, A.; Grau Malonda, A.

    1995-01-01

    We describe a procedure for preparing a stable solution of ''22NaCl for liquid scintillation counting and its counting stability and spectral evolution in Insta-Gel''R is studied. The solution has been standardised in terms of activity concentration by the CIEMAT/NIST method with discrepancies between experimental and computed efficiencies lower than 0.4 % and an overall uncertainty of 0.35 %. (Author) 4 refs

  2. Spectral interpolation and unfolding to measure multi-labelled samples by liquid scintillation

    International Nuclear Information System (INIS)

    Grau Carles, A.; Grau Malonda, A.

    1990-01-01

    A new procedure to determine the activity of each radionuclide in a mixture is described. The information contained in the liquid scintillation pulse height spectra is used. The dilatation, interpolation and contraction steps are essential to obtain a good experimental and computed spectra fitting. The procedure can be applied to mixtures of radionuclides decayin by β - , β - - γ, β + ,β + - γ, EC, EC - γ and isomeric transitions. (Author). 10 refs

  3. Influence of atomic and nuclear constants on the counting efficiency for 55Fe in liquid scintillators

    International Nuclear Information System (INIS)

    Fernandez, A.; Grau, A.; Arcos, J. M. los

    1985-01-01

    In this paper one considers the influence of the different parameters on the determination of the uncertainty of the detection efficiency for 55 F e when the counting technique of liquid scintillation is applied. The following parameters are considered: the relative probabilities of X and Auger emission so as their corresponding energies, the fluorescence yields W K and W L , and the non-interaction probabilities of the emitted X photons. (Author) 11 refs

  4. Preparation and standardization of a sample of P 32 by liquid scintillation

    International Nuclear Information System (INIS)

    Rodriguez, L.; Grau, A.; Los Arcos, J.M.; Suarez, C.

    1988-01-01

    A procedure to standardize P 32 in liquid scintillation counting by labelling a tsributyl phosphate organic molecule is described. This method shows a high counting efficiency, over 99%, while keeping a good stability of samples in PCS or toluene, which vary less that 1% in two weed periods. The global uncertainty that results for calibrating the radioactive solution through this method has been less that 2.2%. (Author)

  5. Measurement by liquid scintillation of 226 Ra coprecipitated in BaSO4

    International Nuclear Information System (INIS)

    Lopez del Rio, H.; Davila R, J.I.; Badillo A, V.E.; Mireles G, F.; Quirino T, L.; Lugo R, J.F.; Pinedo V, J.L.; Rios M, C.

    2003-01-01

    The 226 Ra is one of the more radio toxic nuclides since when entering to the organism it continues metabolically to the calcium, accumulating mainly in the bone tissue where it becomes in an internal radiation source. For the analysis of radium in water the methods of radon emanation are generally applied and coprecipitation with barium sulfate. This last is quick and efficient, and the radium in the precipitate can be measured by alpha or gamma spectrometry, or liquid scintillation dissolving the precipitate one with EDTA. In this work it is proposed a procedure for the radium measurement in water based on the coprecipitation with barium sulfate and in the detection by liquid scintillation. The precipitate of Ba(Ra)SO 4 it is carried with water and blended with the liquid scintillator OptiPhase Hi Safe 3, avoiding the dissolution with EDTA. A 92± 1.4% of radium it was recovered and it was reached a minimum activity detectable of 4.2 ± 0.9 mBq -1 . The procedure was essayed with natural mineral water with a knew activity in concentration of 226 Ra. The analytic result it coincided with the reported value with a relative error of 9%. (Author)

  6. Nuclear recoil scintillation and ionisation yields in liquid xenon from ZEPLIN-III data

    Energy Technology Data Exchange (ETDEWEB)

    Horn, M., E-mail: m.horn@imperial.ac.uk [High Energy Physics group, Blackett Laboratory, Imperial College London (United Kingdom); Belov, V.A.; Akimov, D.Yu. [Institute for Theoretical and Experimental Physics, Moscow (Russian Federation); Araujo, H.M. [High Energy Physics group, Blackett Laboratory, Imperial College London (United Kingdom); Barnes, E.J. [School of Physics and Astronomy, SUPA University of Edinburgh (United Kingdom); Burenkov, A.A. [Institute for Theoretical and Experimental Physics, Moscow (Russian Federation); Chepel, V. [LIP-Coimbra and Department of Physics of the University of Coimbra (Portugal); Currie, A. [High Energy Physics group, Blackett Laboratory, Imperial College London (United Kingdom); Edwards, B. [Particle Physics Department, STFC Rutherford Appleton Laboratory, Chilton (United Kingdom); Ghag, C.; Hollingsworth, A. [School of Physics and Astronomy, SUPA University of Edinburgh (United Kingdom); Kalmus, G.E. [Particle Physics Department, STFC Rutherford Appleton Laboratory, Chilton (United Kingdom); Kobyakin, A.S.; Kovalenko, A.G. [Institute for Theoretical and Experimental Physics, Moscow (Russian Federation); Lebedenko, V.N. [High Energy Physics group, Blackett Laboratory, Imperial College London (United Kingdom); Lindote, A. [LIP-Coimbra and Department of Physics of the University of Coimbra (Portugal); Particle Physics Department, STFC Rutherford Appleton Laboratory, Chilton (United Kingdom); Lopes, M.I. [LIP-Coimbra and Department of Physics of the University of Coimbra (Portugal); Luescher, R.; Majewski, P. [Particle Physics Department, STFC Rutherford Appleton Laboratory, Chilton (United Kingdom); Murphy, A.StJ. [School of Physics and Astronomy, SUPA University of Edinburgh (United Kingdom)

    2011-11-24

    Scintillation and ionisation yields for nuclear recoils in liquid xenon above 10 keV{sub nr} (nuclear recoil energy) are deduced from data acquired using broadband Am-Be neutron sources. The nuclear recoil data from several exposures to two sources were compared to detailed simulations. Energy-dependent scintillation and ionisation yields giving acceptable fits to the data were derived. Efficiency and resolution effects are treated using a light collection Monte Carlo, measured photomultiplier response profiles and hardware trigger studies. A gradual fall in scintillation yield below {approx}40 keV{sub nr} is found, together with a rising ionisation yield; both are in agreement with the latest independent measurements. The analysis method is applied to the most recent ZEPLIN-III data, acquired with a significantly upgraded detector and a precision-calibrated Am-Be source, as well as to the earlier data from the first run in 2008. A new method for deriving the recoil scintillation yield, which includes sub-threshold S1 events, is also presented which confirms the main analysis.

  7. Simple analytical technique for liquid scintillation counting of environmental carbon-14 using gel suspension method

    International Nuclear Information System (INIS)

    Okai, Tomio; Wakabayashi, Genichiro; Nagao, Kenjiro; Matoba, Masaru; Ohura, Hirotaka; Momoshima, Noriyuki; Kawamura, Hidehisa

    2000-01-01

    A simple analytical technique for liquid scintillation counting of environmental 14 C was developed. Commercially available gelling agent, N-lauroyl-L -glutamic -α,γ-dibutylamide, was used for the gel-formation of the samples (gel suspension method) and for the subsequent liquid scintillation counting of 14 C in the form of CaCO 3 . Our procedure for sample preparation is much simpler than that of the conventional methods and requires no special equipment. Self absorption, stability and reproducibility of gel suspension samples were investigated in order to evaluate the characteristics of the gel suspension method for 14 C activity measurement. The self absorption factor is about 70% and slightly decrease as CaCO 3 weight increase. This is considered to be mainly due to the absorption of β-rays and scintillation light by the CaCO 3 sample itself. No change of the counting rate for the gel suspension sample was observed for more than 2 years after the sample preparation. Four samples were used for checking the reproducibility of the sample preparation method. The same values were obtained for the counting rate of 24 C activity within the counting error. No change of the counting rate was observed for the 're-gelated' sample. These results show that the gel suspension method is appropriate for the 14 C activity measurement by the liquid scintillation counting method and useful for a long-term preservation of the sample for repeated measurement. The above analytical technique was applied to actual environmental samples in Fukuoka prefecture, Japan. Results obtained were comparable with those by other researchers and appear to be reasonable. Therefore, the newly developed technique is useful for the routine monitoring of environmental 14 C. (author)

  8. Measuring techniques for environmental sup 3 H, sup 14 C and sup 222 Rn by liquid scintillation counter

    Energy Technology Data Exchange (ETDEWEB)

    Takata, Shigeru; Saito, Masaaki (Tokyo Metropolitan Isotope Research Center (Japan))

    1991-02-01

    Measuring techniques for environmental {sup 3}H, {sup 14}C and {sup 222}Rn with a liquid scintillation counter have been studied. {sup 3}H in environmental water was enriched by electrolysis and measured with a low background liquid scintillation counter. By this technique, {sup 3}H concentration of ground water, river water, sea water and rain water at Tokyo was founded to be 0.1 {approx} 2.5 Bq/1. {sup 14}C in taurine and ethyl-alcohol was measured directly liquid scintillation counter. By this {sup 14}C measuring, natural products, contain low level {sup 14}C, were distinguished from synthesised products contain no {sup 14}C. {sup 222}Rn in toluene extracted from environmental water or air was measured by scintillation pulse interval analysis method. By this technique, {sup 222}Rn was able to be measured under very low background counting rate, 0.03cpm, and high efficiency. (author).

  9. Gross alpha/beta analyses in water by liquid scintillation counting

    International Nuclear Information System (INIS)

    Wong, C.T.; Lawrence Livermore National Laboratory, CA; Soliman, V.M.; Perera, S.K.

    2005-01-01

    The standard procedure for analyzing gross alpha and gross beta in water is evaporation of the sample and radioactivity determination of the resultant solids by proportional counting. This technique lacks precision, and lacks sensitivity for samples with high total dissolved solids. Additionally, the analytical results are dependent on the choice of radionuclide calibration standard and the sample matrix. Direct analysis by liquid scintillation counting has the advantages of high counting efficiencies and minimal sample preparation time. However, due to the small sample aliquants used for analysis, long count times are necessary to reach required detection limits. The procedure proposed consists of evaporating a sample aliquant to dryness, dissolving the resultant solids in a small volume of dilute acid, followed by liquid scintillation counting to determine radioactivity. This procedure can handle sample aliquants containing up to 500 mg of dissolved solids. Various acids, scintillation cocktail mixtures, instrument discriminator settings, and regions of interest (ROI) were evaluated to determine optimum counting conditions. Precision is improved and matrix effects are reduced as compared to proportional counting. Tests indicate that this is a viable alternative to proportional counting for gross alpha and gross beta analyses of water samples. (author)

  10. Interference of dissolved salts in Cerenkov and liquid scintillation estimation of 90Sr

    International Nuclear Information System (INIS)

    Pulhani, Vandana; Jha, S.K.; Tripathi, R.M.; Reddy, Priyanka; Bhade, Sonali

    2014-01-01

    Quenching is the most important effect occurring in Cerenkov and LSC because it affects the efficiency of conversion of β particles into light. Bore well water samples are very often concentrated by evaporation to reduce the detection limit which can also increase the dissolved solid content (TDS) in the sample. Some ground waters are inherently having higher TDS. Self-absorption of beta-particle radiation by the sample especially the lower-energy beta particles depends on sample thickness and density. Environmental samples, after applying the radiochemical procedure, are also estimated by Cerenkov/LSC and might be affected by colour quenching. To get best measurements using Liquid Scintillation and Cerenkov radiations, it is necessary to avoid high salt concentrations and colors which may weaken energy transfers within scintillator cocktails and sample medium. Therefore the degree of self-absorption and quench should be evaluated and taken into account in the calibration. Efficiency is represented as a function spectral quench parameter of external standard SQP(E). The quenching effect of dissolved solids on the efficiency of estimation of 90 Sr by Cerenkov and Liquid Scintillation are studied

  11. Application of PSD for low level alpha counting using liquid scintillation counting

    International Nuclear Information System (INIS)

    Krishnamachari, G.; Vaze, P.K.; Iyer, M.R.

    1989-01-01

    In the liquid scintillator the light produced by alpha particles decays differently than those produced by electrons. Pulse shape discrimination (PSD) methods are employed to estimate low levels of alpha emitting radionuclides by reducing the background due to either beta or gamma events. An attempt is being made to develop a liquid scintillation counting sytem using a simple PSD circuit to achieve a background of 0.01 counts/min. The PSD circuit is based on measuring zero cross over points to differentiate particle types. The input signal is first differentiated by a delay line and subsequently by a RC circuit. The width of the initial part of the doubly differentiated pulse is different for alpha and beta pulses. This width is converted to amplitude by a time-to-amplitude converter (TAC). The higher amplitude pulses from the TAC are due to alpha particles and they are separated by an integral discriminator. The output from the integral discriminator opens a linear gate to record the pulse height spectrum. The figure of merit of the PSD circuit and background in the alpha energy channel have been worked out using different scintillator types. (author). 4 figs

  12. Determination of plutonium-241 by liquid scintillation counting method and its application to environmental samples

    International Nuclear Information System (INIS)

    Watanabe, Miki; Amano, Hikaru

    1997-03-01

    Radionuclides are usually measured by gross counting mode in liquid scintillator counting (LSC) which measures both α and β pulses. This method can easily measure radioactivities, but its background counting is high. Recently reported α-β pulse shape discrimination method (α-β PSD method) in LSC which distinguishes α pulses from β pulses, shows low background counting, so it makes the detection limit lower. The aim of this research is to develop the best method for the determination of 241 Pu which is β-emitter, and Pu isotopes of α-emitters which have long half-lives and stay long in animal body. In this research, two LSC machines was carried out in different scintillators, vial volumes, measurement modes and so on. The following things were found. 1. The liquid scintillator based on naphthalene is proved to be the best separator of α-ray from β-ray, because it acts quickly in energy translation procedure between solvent and aromatic compounds. 2. α-β PSD method makes the background counting rate ten times lower than usual method. It makes the measurement performance better. 3. It is possible to determine 241 Pu in environmental samples around Chernobyl by the combination of LSC and radiochemical separation methods. (author)

  13. Development of a Liquid Scintillator-Based Active Interrogation System for LEU Fuel Assemblies

    International Nuclear Information System (INIS)

    Lavietes, Anthony D.; Plenteda, Romano; Mascahrenas, Nicholas; Cronholm, L. Marie; Aspinall, Michael; Joyce, Malcolm; Tomanin, Alice; Peerani, Paolo

    2013-06-01

    The IAEA, in collaboration with the Joint Research Center (Ispra, IT) and Hybrid Instruments (Lancaster, UK), has developed a full scale, liquid scintillator-based active interrogation system to determine uranium (U) mass in fresh fuel assemblies. The system implements an array of moderate volume (∼1000 ml) liquid scintillator detectors, a multichannel pulse shape discrimination (PSD) system, and a high-speed data acquisition and signal processing system to assess the U content of fresh fuel assemblies. Extensive MCNPX-PoliMi modelling has been carried out to refine the system design and optimize the detector performance. These measurements, traditionally performed with 3 He-based assay systems (e.g., Uranium Neutron Coincidence Collar [UNCL], Active Well Coincidence Collar [AWCC]), can now be performed with higher precision in a fraction of the acquisition time. The system uses a high-flash point, non-hazardous scintillating fluid (EJ309) enabling their use in commercial nuclear facilities and achieves significantly enhanced performance and capabilities through the combination of extremely short gate times, adjustable energy detection threshold, real-time PSD electronics, and high-speed, FPGA-based data acquisition. Given the possible applications, this technology is also an excellent candidate for the replacement of select 3 He-based systems. Comparisons to existing 3 He-based active interrogation systems are presented where possible to provide a baseline performance reference. This paper will describe the laboratory experiments and associated modelling activities undertaken to develop and initially test the prototype detection system. (authors)

  14. Study on quench effects in liquid scintillation counting during tritium measurements

    International Nuclear Information System (INIS)

    Ivana Jakonic; Jovana Nikolov; Natasa Todorovic; Miroslav Veskovic; Branislava Tenjovic

    2014-01-01

    Quench effects can cause a serious reduction in counting efficiency for a given sample/cocktail mixture in liquid scintillation counting (LSC) experiments. This paper presents a simple experiment performed in order to test the influence of quenching on the LSC efficiency of 3 H. The aim of this study was to investigate the behavior of several quench agents with different quench strengths (nitromethane, nitric acid, acetone, dimethyl-sulfoxide) added in different amounts to tritiated water in order to obtain standard sets for quench calibration curves. The OptiPhase HiSafe 2 and OptiPhase HiSafe 3 scintillation cocktails were used in this study in order to compare their quench resistance. Measurements were performed using a low-level LS counter (Wallac, Quantulus 1220). (author)

  15. Background characterization in a liquid scintillation spectrometer; Caracterizacion del fondo de un espectrometro de centelleo liquido

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Barquero, L.; Los Arcos, J.M.; Jimenez de Mingo, A.

    1995-07-01

    An alternate procedure for background count rate estimation in a liquid scintillation spectrometer is presented, which does not require to measure a blank with similar composition, volume and quench, to the problem sample. The procedure is based on a double linear parameterization which was obtained from a systematic study of the background observed with glass vials, in three different windows, 0 - 20 KeV, 0 - 800 KeV and 0 - 2 MeV, for volume between 2 and 20 mi of three commercial scintillators, Hisafe II, Ultima-Gold and Instagel, and quenching degree in the interval equivalent to 50% - 3% tritium efficiency. This procedure was tested with standard samples of 3H, and led to average discrepancies less than 10% for activity {>=}0,6 Bq, against conventional methods for which the discrepancies are twice on average. (Author) 10 refs.

  16. Spectroscopic study of light scattering in linear alkylbenzene for liquid scintillator neutrino detectors

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Xiang; Zhang, Zhenyu [Wuhan University, Hubei Nuclear Solid Physics Key Laboratory, Key Laboratory of Artificial Micro- and Nano-structures of Ministry of Education and School of Physics and Technology, Wuhan (China); Liu, Qian; Zheng, Yangheng [University of Chinese Academy of Sciences, School of Physics, Beijing (China); Han, Junbo [Huazhong University of Science and Technology, Wuhan National High Magnetic Field Center, Wuhan (China); Zhang, Xuan; Ding, Yayun; Zhou, Li; Cao, Jun; Wang, Yifang [Chinese Academy of Sciences, Institute of High Energy Physics, Beijing (China)

    2015-11-15

    We have set up a light scattering spectrometer to study the depolarization of light scattering in linear alkylbenzene. The scattering spectra show that the depolarized part of light scattering is due to Rayleigh scattering. The additional depolarized Rayleigh scattering can make the effective transparency of linear alkylbenzene much better than expected. Therefore, sufficient scintillation photons can transmit through large liquid scintillator detector, such as that of the JUNO experiment. Our study is crucial to achieving an unprecedented energy resolution of 3 %/√(E(MeV)) required for the JUNO experiment to determine the neutrino mass hierarchy. The spectroscopic method can also be used to examine the depolarization of other organic solvents used in neutrino experiments. (orig.)

  17. Spectroscopic study of light scattering in linear alkylbenzene for liquid scintillator neutrino detectors

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Xiang, E-mail: xiangzhou@whu.edu.cn [Hubei Nuclear Solid Physics Key Laboratory, Key Laboratory of Artificial Micro- and Nano-structures of Ministry of Education and School of Physics and Technology, Wuhan University, 430072, Wuhan (China); Liu, Qian, E-mail: liuqian@ucas.ac.cn [School of Physics, University of Chinese Academy of Sciences, 100049, Beijing (China); Han, Junbo [Wuhan National High Magnetic Field Center, Huazhong University of Science and Technology, 430074, Wuhan (China); Zhang, Zhenyu [Hubei Nuclear Solid Physics Key Laboratory, Key Laboratory of Artificial Micro- and Nano-structures of Ministry of Education and School of Physics and Technology, Wuhan University, 430072, Wuhan (China); Zhang, Xuan; Ding, Yayun [Institute of High Energy Physics, Chinese Academy of Sciences, 100049, Beijing (China); Zheng, Yangheng [School of Physics, University of Chinese Academy of Sciences, 100049, Beijing (China); Zhou, Li; Cao, Jun; Wang, Yifang [Institute of High Energy Physics, Chinese Academy of Sciences, 100049, Beijing (China)

    2015-11-21

    We have set up a light scattering spectrometer to study the depolarization of light scattering in linear alkylbenzene. The scattering spectra show that the depolarized part of light scattering is due to Rayleigh scattering. The additional depolarized Rayleigh scattering can make the effective transparency of linear alkylbenzene much better than expected. Therefore, sufficient scintillation photons can transmit through large liquid scintillator detector, such as that of the JUNO experiment. Our study is crucial to achieving an unprecedented energy resolution of 3 %/√(E(MeV)) required for the JUNO experiment to determine the neutrino mass hierarchy. The spectroscopic method can also be used to examine the depolarization of other organic solvents used in neutrino experiments.

  18. Detection of environmental radioactive contamination levels using a liquid-scintillation counter

    International Nuclear Information System (INIS)

    Calisto, W.; Kun, A.; Campos, E.

    1981-01-01

    A high-efficiency LS-100 C liquid scintillation counter was used to detect low levels of environmental activity. Different concentrations of primary scintillator were tested and these established the most suitable values. Work was carried out at the same time to find conditions which would ensure a low background and high efficiency. To reduce the sample volume used, various types of chelating agents were utilized: 8-hydroxyquinoline (oxine), tannic acid, cupferron, dimethylglioxime and beta-naphthol. These were tested at pH levels of 1, 6 and 11. Measurements were performed by means of the Cerenkov effect using substances with differing refraction indices - 26% sodium chloride, water, glycerine, carbon bisulphide, nitrobenzene, benzyl alcohol and toluene. Finally, work was done on comparing spectra obtained by Cerenkov radiation and by 90 Sr and 90 Y beta radiation respectively. Clearly differentiated zones were obtained, thus making it possible to distinguish one isotope from another in an equilibrium solution. (author)

  19. Cherenkov radiation effects on counting efficiency in extremely quenched liquid scintillation samples

    International Nuclear Information System (INIS)

    Grau Carles, A.; Grau Malonda, A.; Rodriguez Barquero, L.

    1993-01-01

    The CIEMAT/NIST tracer method has successfully standardized nuclides with diverse quench values and decay schemes in liquid scintillation counting. However, the counting efficiency is computed inaccurately for extremely quenched samples. This article shows that when samples are extremely quenched, the counting efficiency in high-energy beta-ray nuclides depends principally on the Cherenkov effect. A new technique is described for quench determination, which makes the measurement of counting efficiency possible when scintillation counting approaches zero. A new efficiency computation model for pure beta-ray nuclides is also described. The results of the model are tested experimentally for 89 Sr, 90 Y, 36 Cl and 204 Tl nuclides with independence of the quench level. (orig.)

  20. Occulting Light Concentrators in Liquid Scintillator Neutrino Detectors

    Science.gov (United States)

    Buizza Avanzini, Margherita; Cabrera, Anatael; Dusini, Stefano; Grassi, Marco; He, Miao; Wu, Wenjie

    2017-09-01

    The experimental efforts characterizing the era of precision neutrino physics revolve around collecting high-statistics neutrino samples and attaining an excellent energy and position resolution. Next generation liquid-based neutrino detectors, such as JUNO, HyperKamiokande, etc, share the use of a large target mass, and the need of pushing light collection to the edge for maximal calorimetric information. Achieving high light collection implies considerable costs, especially when considering detector masses of several kt. A traditional strategy to maximize the effective photo-coverage with the minimum number of PMTs relies on Light Concentrators (LC), such as Winston Cones. In this paper, the authors introduce a novel concept called Occulting Light Concentrators (OLC), whereby a traditional LC gets tailored to a conventional PMT, by taking into account its single-photoelectron collection efficiency profile and thus occulting the worst performing portion of the photocathode. Thus, the OLC shape optimization takes into account not only the optical interface of the PMT, but also the maximization of the PMT detection performances. The light collection uniformity across the detector is another advantage of the OLC system. By considering the case of JUNO, we will show OLC capabilities in terms of light collection and energy resolution.

  1. Total alpha and beta determination by liquid scintillation counting in water samples from a Brazilian intercomparison exercise

    International Nuclear Information System (INIS)

    Dias, Fabiana F.; Taddei, Maria Helena T.; Pontedeiro, Elizabeth May Braga Dulley

    2009-01-01

    This paper describes CNEN/LAPOC's participation in the Brazilian Intercomparison Exercise (PNI) for simultaneous determination of total radioactivity in water samples, which took place in August and December 2008. The Proficiency Test (PT) also involved a short description of the nuclear analytical technique employed, emphasizing sources of uncertainty. A Liquid Scintillation System (Packard TRICARB 2700) was used with appropriate corrections applied to final results, expressed as Bq L -1 . Participation and PT data provide independent information on performance of a Laboratory and have an important role in method validation; especially because it allows the assessment of method performance over an entire range of concentrations and matrices. PT is also an important tool to demonstrate equivalence of measurements, if not their metrological comparability, and to promote education and improvement of Lab practices. (author)

  2. A Monte Carlo Model for Neutron Coincidence Counting with Fast Organic Liquid Scintillation Detectors

    International Nuclear Information System (INIS)

    Gamage, Kelum A.A.; Joyce, Malcolm J.; Cave, Frank D.

    2013-06-01

    Neutron coincidence counting is an established, nondestructive method for the qualitative and quantitative analysis of nuclear materials. Several even-numbered nuclei of the actinide isotopes, and especially even-numbered plutonium isotopes, undergo spontaneous fission, resulting in the emission of neutrons which are correlated in time. The characteristics of this i.e. the multiplicity can be used to identify each isotope in question. Similarly, the corresponding characteristics of isotopes that are susceptible to stimulated fission are somewhat isotope-related, and also dependent on the energy of the incident neutron that stimulates the fission event, and this can hence be used to identify and quantify isotopes also. Most of the neutron coincidence counters currently used are based on 3 He gas tubes. In the 3 He-filled gas proportional-counter, the (n, p) reaction is largely responsible for the detection of slow neutrons and hence neutrons have to be slowed down to thermal energies. As a result, moderator and shielding materials are essential components of many systems designed to assess quantities of fissile materials. The use of a moderator, however, extends the die-away time of the detector necessitating a larger coincidence window and, further, 3 He is now in short supply and expensive. In this paper, a simulation based on the Monte Carlo method is described which has been performed using MCNPX 2.6.0, to model the geometry of a sector-shaped liquid scintillation detector in response to coincident neutron events. The detection of neutrons from a mixed-oxide (MOX) fuel pellet using an organic liquid scintillator has been simulated for different thicknesses of scintillators. In this new neutron detector, a layer of lead has been used to reduce the gamma-ray fluence reaching the scintillator. The effect of lead for neutron detection has also been estimated by considering different thicknesses of lead layers. (authors)

  3. Triton X-100 as a complete liquid scintillation cocktail for counting aqueous solutions and ionic nutrient salts

    International Nuclear Information System (INIS)

    Reed, D.W.

    1984-01-01

    Triton X-100, used alone, was found to act as a complete liquid scintillation cocktail. Triton X-100 acted as a scintillator and the effect was not due to Cerenkov radiation. A variety of other commercially available surfactants also acted as scintillators, but with different levels of efficiency. Triton X-100/water combinations were suitable for counting aqueous solutions of 33 P and 86 Rb and the count rate was stable over extended periods of time. Triton X-100/toluene combinations also yielded high counting efficiencies. Triton X-100 was more sensitive to quenching than standard cocktails containing fluors. (author)

  4. Determination of 131I in milk using a liquid scintillation technique

    International Nuclear Information System (INIS)

    Palagyi, S.; Markusova, R.

    1978-01-01

    The method is based on the specific extraction of radioiodine using a liquid anion exchanger and measuring its radioactivity with a toluene based liquid scintillator. Milk proteins are precipitated with trichloroacetic acid and separated by filtration through asbestos. Radioiodine from whey is oxidized to I 2 with NaNO 2 or H 2 O 2 and purified by a benzene-water extraction cycle using sodium sulphite. Finally, the radioiodine is separated and concentrated into toluene solution of a liquid anion exchanger. Before radioactivity counting, the organic phase is decolourized with Na 2 SO 3 using methanol as solubilizer. The method takes about 2.5 hrs without radioactivity counting. The radiochemical yield is higher than 70% and the counting efficiency is 82%. (author)

  5. A study of the scintillation induced by alpha particles and gamma rays in liquid xenon in an electric field

    International Nuclear Information System (INIS)

    Dawson, J.V.; Howard, A.S.; Akimov, D.; Araujo, H.; Bewick, A.; Davidge, D.C.R.; Jones, W.G.; Joshi, M.; Lebedenko, V.N.; Liubarsky, I.; Quenby, J.J.; Rochester, G.; Shaul, D.; Sumner, T.J.; Walker, R.J.

    2005-01-01

    Scintillation produced in liquid xenon by alpha particles and gamma rays has been studied as a function of applied electric field. For back scattered gamma rays with energy of about 200keV, the number of scintillation photons was found to decrease by 64±2% with increasing field strength. Consequently, the pulse shape discrimination power between alpha particles and gamma rays is found to reduce with increasing field, but remaining non-zero at higher fields

  6. Liquid scintillation counting standardization of ''125 I in organic and inorganic samples by the CIEMAT/NIST method

    International Nuclear Information System (INIS)

    Rodriguez Barquero, L.; Grau Malonda, A.; Los Arcos Merino, J.M.; Grau Carles, A.

    1994-01-01

    The liquid scintillation counting standardization of organic and inorganic samples of ''125 I by the CIEMAT/NIST method using five different scintillators is described. The discrepancies between experimental and computed efficiencies are lower than 1.4% and 1.7%, for inorganic and organic samples, respectively, in the interval 421-226 of quenching parameter. Both organic and inorganic solutions have been standardized in terms of activity concentration to an overall uncertainty of 0.76%

  7. Liquid scintillation counting standardization of 125I in organic and inorganic samples by the CIEMAT/NIST method

    International Nuclear Information System (INIS)

    Rodriguez Barquero, L.; Grau Malonda, A.; Los Arcos Merino, J. M.; Grau Carles, A.

    1994-01-01

    The liquid scintillation counting standardization of organic and inorganic samples of ''I25I by the CIEMAT/NIST method using five different scintillators is described. The discrepancies between experimental and computed efficiencies are lower than 1.4% and 1.7%, for inorganic and organic samples, respectively, in the interval 421-226 of quenching parameter. Both organic and inorganic solutions have been standardized in terms of activity concentration to an overall uncertainty of 0.76%. (Author) 14 refs

  8. A feasibility study of boron-loaded liquid scintillator for the detection of electron anti-neutrinos

    CERN Document Server

    Wang, S C; Leung, R W S; Wang, S L; Chang, C Y; Chen Chi Ping; Cheng, K C; Ho, T I; Lai, W P; Liu, H M; Mao, Z P; Shih, I C; Wong, H T; Yu, Z Q

    1999-01-01

    Boron-loaded liquid scintillator offers some potential advantages as a detector for electron anti-neutrinos. A research program was carried out with the objective of developing such scintillators. The crucial feature is the pulse shape discrimination properties following the neutron capture by sup 1 sup 0 B. Results of the R and D efforts are presented. The feasibility and the technical difficulties of carrying out a full-scale neutrino experiment based on this approach are discussed. (author)

  9. Neutron detection in a high gamma-ray background with EJ-301 and EJ-309 liquid scintillators

    International Nuclear Information System (INIS)

    Stevanato, L.; Cester, D.; Nebbia, G.; Viesti, G.

    2012-01-01

    Using a fast digitizer, the neutron–gamma discrimination capability of the new liquid scintillator EJ-309 is compared with that obtained using standard EJ-301. Moreover the capability of both the scintillation detectors to identify a weak neutron source in a high gamma-ray background is demonstrated. The probability of neutron detection is PD=95% at 95% confidence level for a gamma-ray background corresponding to a dose rate of 100 μSv/h.

  10. The determination of Pu-241 by liquid scintillation counting in liquid effluents of the Karlsruhe Nuclear Research Center

    International Nuclear Information System (INIS)

    Godoy, J.M.; Schuettelkopf, H.; Pimpl, M.

    1983-04-01

    A procedure was developed to measure Pu-241 by liquid scintillation counting. Sample preparation was performed by electroplating of plutonium on stainless steel planchets. To correct the selfabsorption, the linear dependence of counting efficiency in the liquid scintillation counter from the resolution in the alpha spectrometer was used. Pu-238, Pu-239+240 and Pu-241 were measured in the liquid effluents of the Karlsruhe Nuclear Research Center (KfK). The concentrations in monthly mixed samples ranged from 0.07 until 46 nCi Pu-238/m 3 , from 0.13 until 2.1 nCi Pu-239+240/m 3 and from 25 until 190 nCi Pu-241/m 3 . Between 5.4% and 41% of the plutonium content of the KfK waste water are released to the River Old Rhine. The values for the activity ratio Pu-238/Pu-239+240 are between 0.39 and 1.1 and for Pu-241/Pu-239+240 are between 11 and 300. The mean value for Pu-241/Pu-239+240 is 61. The dose exposure of the environmental population of the Karlsruhe Nuclear Research Center caused by released Pu-241 is negligible low. (orig./HP) [de

  11. Determination of 129I using distillation method and liquid scintillation spectrometry

    International Nuclear Information System (INIS)

    Horvathova, B.; Dulanska, S.; Remenec, B.; Matel, L.; Gardonova, V.

    2014-01-01

    The conditions for effective distillation of iodine as a screening method for the determination of 129 I by liquid scintillation spectrometry were optimized. By distillation of iodine it is possible to achieve high-purity fraction without interferences needed for measuring 129 I for liquid scintillation spectrometer. Yields of separation were determined gravimetrically using PdI 2 ·H 2 O. The environment that was found to be effective for distillation of iodine is made up of 1 - 2 mol dm -3 HNO 3 together with 0.4 g of NaNO 2 as an oxidizing agent (I . →I 2 ). For testing of distillation, suitable apparatus for distillation of iodine was designed. The apparatus was connected to a vacuum box, which sucks iodine of the distilled solution. Then the iodine was captured in a solution of NaOH at a concentration of 1.5 mol dm -3 . As part of the optimization methodology, it was found that the concentration of NaOH solution for adsorption I 2 (g) does not have any influence on the yields, as opposed to its volume, where it is necessary to use a maximum amount of NaOH in the holding flask for maximum adsorption of iodine. It was determined, that time needed for coagulation PdI 2 ·H 2 O is 24 hours and suitable time for distillation was 20 minutes. Optimized method for the determination of 129 I was applied for various matrices from NPPs in Slovak Republic. Values of 129 I for all analyzed samples were less than the minimum detectable activity (0.043 Bq). The separation yields were in the range (73.14 to 82.04)% and 129 I was measured on a liquid scintillation spectrometer TRI CARB 2900TR with high detection efficiency of 95%. (authors)

  12. QUENCH: A software package for the determination of quenching curves in Liquid Scintillation counting.

    Science.gov (United States)

    Cassette, Philippe

    2016-03-01

    In Liquid Scintillation Counting (LSC), the scintillating source is part of the measurement system and its detection efficiency varies with the scintillator used, the vial and the volume and the chemistry of the sample. The detection efficiency is generally determined using a quenching curve, describing, for a specific radionuclide, the relationship between a quenching index given by the counter and the detection efficiency. A quenched set of LS standard sources are prepared by adding a quenching agent and the quenching index and detection efficiency are determined for each source. Then a simple formula is fitted to the experimental points to define the quenching curve function. The paper describes a software package specifically devoted to the determination of quenching curves with uncertainties. The experimental measurements are described by their quenching index and detection efficiency with uncertainties on both quantities. Random Gaussian fluctuations of these experimental measurements are sampled and a polynomial or logarithmic function is fitted on each fluctuation by χ(2) minimization. This Monte Carlo procedure is repeated many times and eventually the arithmetic mean and the experimental standard deviation of each parameter are calculated, together with the covariances between these parameters. Using these parameters, the detection efficiency, corresponding to an arbitrary quenching index within the measured range, can be calculated. The associated uncertainty is calculated with the law of propagation of variances, including the covariance terms. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Some rules to improve the energy resolution in alpha liquid scintillation with beta rejection

    CERN Document Server

    Aupiais, J; Dacheux, N

    2003-01-01

    Two common scintillating mixtures dedicated to alpha measurements by means of alpha liquid scintillation with pulse shape discrimination were tested: the di-isopropylnaphthalene - based and the toluene-based solvents containing the commercial cocktails Ultima Gold AB trademark and Alphaex trademark. We show the possibility to enhance the resolution up to 200% by using no-water miscible cocktails and by reducing the optical path. Under these conditions, the resolution of about 200 keV can be obtained either by the Tri Carb sup T sup M or by the Perals sup T sup M spectrometers. The time responses, e.g., the time required for a complete energy transfer between the initial interaction alpha particle-solvent and the final fluorescence of the organic scintillator, have been compared. Both cocktails present similar behavior. According to the Foerster theory, about 6-10 ns are required to complete the energy transfer. For both apparatus, the detection limits were determined for alpha emitters. The sensitivity of the...

  14. Accurate disintegration-rate measurement of 55Fe by liquid scintillation counting

    International Nuclear Information System (INIS)

    Steyn, J.; Oberholzer, P.; Botha, S.M.

    1979-01-01

    A method involving liquid scintillation counting is described for the accurate measurement of disintegration rate of 55 Fe. The method is based on the use of calculated efficiency functions together with either of the nuclides 54 Mn and 51 Cr as internal standards for measurement of counting efficiencies by coincidence counting. The method was used by the NAC during a recent international intercomparison of radioactivity measurements, and a summary of the results obtained by nine participating laboratories is presented. A spread in results of several percent is evident [af

  15. Data transfer from Beckman LS 5800 liquid scintillation counters to IBM personal computers.

    Science.gov (United States)

    Maan, A C

    1985-09-01

    This communication describes a short routine in BASICA for the IBM-PC, written to collect data from a Beckman liquid scintillation counter. In the form presented here the routine converts incoming bytes into separate lines and saves these lines in a file. There are many possible applications for further use of the data in these files. A few suggestions are given as to the format in which data can be stored and how to process these data automatically after all samples have been counted. The only hardware needed is an asynchronous communications adapter for the IBM-PC and an RS232 cable.

  16. A rope-net support system for the liquid scintillator detector for the SNO+ experiment

    Energy Technology Data Exchange (ETDEWEB)

    Bialek, A., E-mail: abialek@snolab.ca [University of Alberta, Edmonton (Canada); Chen, M. [Queen' s University, Kingston (Canada); Cleveland, B. [SNOLAB, Lively (Canada); Gorel, P.; Hallin, A. [University of Alberta, Edmonton (Canada); Harvey, P.J.; Heise, J. [Queen' s University, Kingston (Canada); Kraus, C. [Laurentian University, Sudbury (Canada); Krauss, C.B. [University of Alberta, Edmonton (Canada); Lawson, I. [SNOLAB, Lively (Canada); Ng, C.J.; Pinkney, B. [University of Alberta, Edmonton (Canada); Rogowsky, D.M. [Rogowsky Engineering Ltd, AECOM Canada Ltd (Canada); Sibley, L.; Soluk, R.; Soukup, J. [University of Alberta, Edmonton (Canada); Vázquez-Jáuregui, E. [SNOLAB, Lively (Canada); Laurentian University, Sudbury (Canada)

    2016-08-11

    The detector for the SNO+ experiment consists of 780 000 kg of liquid scintillator contained in an acrylic vessel that is surrounded by water. A mechanical system has been installed to counteract the 1.25 MN of buoyant force on the acrylic and prevent the vessel from moving. The system is a rope net, designed using a Finite Element Analysis to calculate the amount of stress on the acrylic induced by the ropes, hydrostatic pressures and gravity. A dedicated test was performed to measure strains in the acrylic arising from the complex geometry of the knots in the rope system. The ratio between measured and FEA calculated strains was 1.3.

  17. Determination of 90SR in food using extraction chromatography and LSC - Liquid Scintillation Counting

    International Nuclear Information System (INIS)

    Temba, Eliane S.C.; Amaral, Angela M.; Reis Junior, Aluisio S.; Monteiro, Roberto P.G.

    2013-01-01

    A methodology for the determination of 90 Sr in food is described. The procedure involved a preliminary freeze-drying of the samples followed by dry-ashing and sample digestion. The separation procedure was carried out using extraction chromatography with Sr Resin, from Eichrom, and 90 Sr was measured by liquid scintillation counting (LSC). A certified reference material, IAEA-375, was analyzed in order to evaluate the reliability of the method, and the results showed good agreement between the measured and certified values. The chemical yield was above 90% and the typical counting efficiency was 82%. The calculated limit of detection was 4.8 x 10 -3 Bq g -1 . (author)

  18. Age determination of trace plutonium using liquid scintillation counting and α-spectrometry

    International Nuclear Information System (INIS)

    Chen Yan; Chang Zhiyuan; Zhao Yonggang; Li Jinghuai; Shu Fujun

    2010-01-01

    Liquid scintillation counting combined with α-spectrometry through measuring 241 Pu/ 241 Am ratio to determine the age of trace Pu was studied. The technique was explored for the age determination of nanogram grade Pu sample on the basis of Pu/Am separation. The ages of two Pu samples-one with known and the other with unknown age were determined by the method. The determined age by the method is in agreement with the reference value. The established method for determining the age of trace Pu can be adopted in the verification activities of nuclear safeguards and nuclear arms control. (authors)

  19. Mixed incineration of RAIW and liquid scintillator waste after storage for decay

    International Nuclear Information System (INIS)

    Naba, K.; Nakazato, K.; Kataoka, K.

    1993-01-01

    Most medical radioactive waste is combustible after radioactive decay. Moreover mixed incineration of LLW with biomedical radioactive waste will lessen radiation exposure to the public. This paper describes the total system flowsheet for the processing of liquid scintillator wastes and radioimmunoassay tube wastes containing iodine 125 (after a two-year storage for decay). The process was tested with a 60 kg/hr capacity incinerator from 1987 to 1991; this has been upgraded to a 150 kg/hr incinerator which is used for nonradioactive biomedical waste incineration as well

  20. Evaluation of the uncertainty for the efficiency curve determination of 210Pb by liquid scintillation

    International Nuclear Information System (INIS)

    Sampaio, C.S.; Sousa, W.O.; Dantas, B.M.

    2014-01-01

    Methodologies for the evaluation of uncertainties associated with the determination of the efficiency curve of 210 Pb by liquid scintillation counting (LSC) are presented. No statistical difference were found when compared the uncertainties of the curves that represented the counting net before and after the secular equilibrium between 210 Pb and 210 Bi, nether when compared the curves when counting only 210 Pb and the curve with the total count of 210 Pb and 210 Bi, for the same time interval after precipitation. (author)

  1. Neutron-gamma discrimination employing pattern recognition of the signal from liquid scintillator

    International Nuclear Information System (INIS)

    Kamada, Kohji; Enokido, Uhji; Ogawa, Seiji

    1999-01-01

    A pattern recognition method was applied to the neutron-gamma discrimination of the pulses from the liquid scintillator, NE-213. The circuit for the discrimination is composed of A/D converter, fast SCA, memory control circuit, two digital delay lines and two buffer memories. All components are packed on a small circuit board and are installed into a personal computer. Experiments using a weak 252 Cf n-γ source were undertaken to test the feasibility of the circuit. The circuit is of very easy adjustment and, at the same time, of very economical price when compared with usual discrimination circuits, such as the TAC system

  2. Neutron-gamma discrimination employing pattern recognition of the signal from liquid scintillator

    CERN Document Server

    Kamada, K; Ogawa, S

    1999-01-01

    A pattern recognition method was applied to the neutron-gamma discrimination of the pulses from the liquid scintillator, NE-213. The circuit for the discrimination is composed of A/D converter, fast SCA, memory control circuit, two digital delay lines and two buffer memories. All components are packed on a small circuit board and are installed into a personal computer. Experiments using a weak sup 2 sup 5 sup 2 Cf n-gamma source were undertaken to test the feasibility of the circuit. The circuit is of very easy adjustment and, at the same time, of very economical price when compared with usual discrimination circuits, such as the TAC system.

  3. Measurement of tissue free water tritium in biological samples by liquid scintillation counter

    International Nuclear Information System (INIS)

    Wu Zongmei; Zheng Xiaomin

    1993-01-01

    The authors introduced a method of extracting tissue free water tritium (TFWT) by the azeotropic distribution with toluene and of measuring the activity of the TFWT in biological samples by liquid scintillation counter. The TFWT recovery ratio of pine needles (fresh), green vegetables, radish, rice, pork (muscle) and milk is 0.90, 0.95, 0.96, 0.90, 0.52 and 0.85, and TFWT activity is 1.8, 3.2, 1.8, 2.7, 3.3 and 4.0 Bq/L-H 2 O, respectively

  4. Activity measurement of tritium in biological samples by azeotropic distillation liquid scintillation counter

    International Nuclear Information System (INIS)

    Wu Zongmei; Zheng Xiaomin

    1994-01-01

    The authors introduced a method of extracting tissue free water tritium (TFWT) in biological samples by azeotropic distillation with toluene and of measuring its activity by liquid scintillation counter. Measured TFWT recovery ratios of pine needles (fresh), green vegetables, radish, milk, meat, rice are 0.90, 0.95, 0.95, 0.85, 0.53 and 0.90; and the activities of TFWT are 1.8, 3.2, 1.8, 4.0, 3.3 and 2.7 Bq/L, respectively

  5. Measuring the emulsion stability in Cherenkov radiation with insignificant modification of a liquid scintillation spectrometer

    International Nuclear Information System (INIS)

    Wiechen, A.; Lorenzen, P.Ch.; Reimerdes, E.H.

    1984-01-01

    A method is described by which the stability of emulsions can be measured by a modified liquid scintillation counter. The 226 Ra external standard source of a commercially available equipment, fixed in the measuring position, is used for the production of Cherenkov radiation in a sample of an emulsion. This Cherenkov radiation is absorbed by the sample due to its turbidity. The turbidity of emulsions follows a typical course with time designated as creaming-up-curve. These curves can be registered automatically in digital form. (author)

  6. Determination of radon in indoor air in Quebec by liquid scintillation counting in ortho-xylene

    Energy Technology Data Exchange (ETDEWEB)

    Chah, B; Zikovsky, L; Champagne, P [Ecole Polytechnique, Montreal, PQ (Canada)

    1992-01-01

    A new method for the determination of radon in air has been developed. it is based on low temperature absorption of radon in ortho-xylene followed by liquid scintillation counting. The method is reasonably fast and sensitive enough to analyse air without precipitation. The detection limit at the 95% confidence level for a 20 l air sample and 1 h counting time is 2 mBql{sup -1}. Radon concentrations measured in indoor air in Quebec varied from 7 to 162 mBql{sup -1}. (Author).

  7. Isolation and activity determination of 99Tc in nuclear waste by liquid scintillation counting

    International Nuclear Information System (INIS)

    Reis Junior, Aluisio S.; Temba, Eliane S.C.; Kastner, Geraldo F.; Monteiro, Roberto P.G.

    2011-01-01

    A radiochemical separation and purification for technetium was proposed for radioactive waste in which rhenium is to be used as a yield monitor. The separation was performed by anion exchange chromatography and the purification was performed by extraction chromatography using a TEVA resin.The determination of 99 Tc was by liquid scintillation counting and rhenium was activated by Triga Mark 1 research reactor and measured by gamma spectrometry. Some real samples of nuclear waste such as evaporator concentrate and filter were analysed. The chemical recovery determined using rhenium as tracer was around 90 %. (author)

  8. Electro-removal of H-3 and C-14 contained in scintillation liquid absorbed in soils type Phaeozem

    International Nuclear Information System (INIS)

    Valdovinos, V.; Bustos, E.; Monroy G, F.

    2014-10-01

    This paper presents the results of electro-removal, an electrochemical treatment in soils contaminated with H-3 and C-14 contained in scintillation liquids absorbed in soils. For this purpose the best electrochemical conditions were used, which are: scintillation liquid Ultima Gold Xr, water (1:1) and 1 m A in the passage of current. The media were characterized before and after of applying the different potentials by various analytical techniques, such as: liquids by gas chromatography with a flame ionization detector, solids and liquids by Fourier transform infrared spectroscopy (Ftir) and electrodes by scanning electron microscopy with elemental analysis by energy-dispersive X-ray spectroscopy. Later standard samples with H-3 and C-14 were prepared and the electrochemical treatment was applied to previously established conditions. After electrochemical treatment the scintillation liquid characterization was performed by gas chromatography and a scintillation counter to see the disintegrations per minute. According to results of Ftir, soils show no deterioration and in the liquid phase the amount of water increases as the applied potential, due to oxidation-reduction reactions where happen modification or mineralization of organic molecules (H 2 O and CO 2 formation). In 4 h of treatment, removal percentages in the liquid phase, were: 53.6% of H-3 and 11.6% of C-14. (Author)

  9. Comparison of accelerator mass spectrometric measurement with liquid scintillation counting measurement for the determination of 14C in environmental samples

    International Nuclear Information System (INIS)

    Yasuike, Kaeko; Yamada, Yoshimune; Amano, Hikaru

    2010-01-01

    The concentrations of organically-bound 14 C in tree-ring cellulose of a Japanese Black Pine grown in Shika-machi (37.0 deg. N, 136.8 deg. E) and those of a Japanese Cedar grown in Kanazawa (36.5 deg. N, 136.7 deg. E), Japan, were analyzed for the ring-years from 1989 to 1998 by the accelerator mass spectrometric measurement. The results were compared with those of the same samples analyzed by the liquid scintillation counting measurement to determine the reliability of liquid scintillation counting measurement. An important result of this study is that the sensitivity and reproducibility of accelerator mass spectrometric measurement was almost equal to that of liquid scintillation counting measurement.

  10. Determination of Np, Pu and Am in high level radioactive waste with extraction-liquid scintillation counting

    International Nuclear Information System (INIS)

    Yang Dazhu; Zhu Yongjun; Jiao Rongzhou

    1994-01-01

    A new method for the determination of transuranium elements, Np, Pu and Am with extraction-liquid scintillation counting has been studied systematically. Procedures for the separation of Pu and Am by HDEHP-TRPO extraction and for the separation of Np by TTA-TiOA extraction have been developed, by which the recovery of Np, Pu and Am is 97%, 99% and 99%, respectively, and the decontamination factors for the major fission products ( 90 Sr, 137 Cs etc.) are 10 4 -10 6 . Pulse shape discrimination (PSD) technique has been introduced to liquid scintillation counting, by which the counting efficiency of α-activity is >99% and the rejection of β-counts is >99.95%. This new method, combining extraction and pulse shape discrimination with liquid scintillation technique, has been successfully applied to the assay of Np, Pu and Am in high level radioactive waste. (author) 7 refs.; 7 figs.; 4 tabs

  11. Measurement of the muon-induced neutron yield in liquid scintillator and stainless steel at LNGS with the LVD experiment

    International Nuclear Information System (INIS)

    Persiani, R.; Garbini, M.; Sartorelli, G.; Selvi, M.

    2013-01-01

    We describe the measurement of the muon-induced neutron yield in liquid scintillator and stainless steel (SS) at the Gran Sasso National Laboratory (LNGS), with the LVD experiment. The Large Volume Detector (LVD) is located in Hall A of the LNGS and is made of 1000 t of liquid scintillator and 1000 t of SS. Using an independent measurement to evaluate the background and with the support of a full Monte Carlo simulation based on Geant4, we measured a neutron yield of (2.9±0.6)×10 −4 and (1.5±0.3)×10 −3 in liquid scintillator and in stainless steel, respectively

  12. The accurate measurement of the disintegration rate of 55Fe using an internal liquid scintillation counter

    International Nuclear Information System (INIS)

    Botha, S.M.

    1979-01-01

    As the well-known 4πX-γ-coincidence method cannot be used directly to find the disintegration rate of 55 Fe, another method was developed in which a tracer nuclide, possessing coincident gamma radiation, was used. It was now possible to determine the disintegration rate indirectly by the coincidence method using an internal liquid scintillation counter. 54 Mn and 51 Cr which lie in the immediate vicinity of iron in the series of nuclides, are suitable tracers. They are also electron capture nuclides, but decaying to an excited state, were counted by the 4πX-γ-coincidence method. A mixed source, containing 55 Fe and the tracer, was also counted by the coincidence method so that the 4π-counting rate of 55 Fe was obtained as function of the tracer's counting efficiency. It was also essential to find a relationship between the counting efficiencies of the liquid scintillation counter for 55 Fe and the tracer. This relationship is called the effeciency function. Efficiency functions were calculated for 55 Fe and 54 Mn as well as for 55 Fe and 51 Cr. Finally the radioactive concentration of a solution of 55 Fe had been carefully determined by using 54 Mn and 51 Cr tracers. The results for the two different tracers agreed within the statistical uncertainty of 0,4%. The systematic uncertainty on the final results was estimated as 0,17%

  13. Standardization of Ga-68 by coincidence measurements, liquid scintillation counting and 4πγ counting

    International Nuclear Information System (INIS)

    Roteta, Miguel; Peyres, Virginia; Rodríguez Barquero, Leonor; García-Toraño, Eduardo; Arenillas, Pablo; Balpardo, Christian; Rodrígues, Darío; Llovera, Roberto

    2012-01-01

    The radionuclide 68 Ga is one of the few positron emitters that can be prepared in-house without the use of a cyclotron. It disintegrates to the ground state of 68 Zn partially by positron emission (89.1%) with a maximum energy of 1899.1 keV, and partially by electron capture (10.9%). This nuclide has been standardized in the frame of a cooperation project between the Radionuclide Metrology laboratories from CIEMAT (Spain) and CNEA (Argentina). Measurements involved several techniques: 4πβ−γ coincidences, integral gamma counting and Liquid Scintillation Counting using the triple to double coincidence ratio and the CIEMAT/NIST methods. Given the short half-life of the radionuclide assayed, a direct comparison between results from both laboratories was excluded and a comparison of experimental efficiencies of similar NaI detectors was used instead. - Highlights: ► We standardized the positron emitter Ga-68 in a bilateral cooperation. ► We used several techniques, as coincidence, integral gamma and liquid scintillation. ► An efficiency comparison replaced a direct comparison of reference materials.

  14. A neutron multiplicity analysis method for uranium samples with liquid scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Hao, E-mail: zhouhao_ciae@126.com [China Institute of Atomic Energy, P.O.BOX 275-8, Beijing 102413 (China); Lin, Hongtao [Xi' an Reasearch Institute of High-tech, Xi' an, Shaanxi 710025 (China); Liu, Guorong; Li, Jinghuai; Liang, Qinglei; Zhao, Yonggang [China Institute of Atomic Energy, P.O.BOX 275-8, Beijing 102413 (China)

    2015-10-11

    A new neutron multiplicity analysis method for uranium samples with liquid scintillators is introduced. An active well-type fast neutron multiplicity counter has been built, which consists of four BC501A liquid scintillators, a n/γdiscrimination module MPD-4, a multi-stop time to digital convertor MCS6A, and two Am–Li sources. A mathematical model is built to symbolize the detection processes of fission neutrons. Based on this model, equations in the form of R=F*P*Q*T could be achieved, where F indicates the induced fission rate by interrogation sources, P indicates the transfer matrix determined by multiplication process, Q indicates the transfer matrix determined by detection efficiency, T indicates the transfer matrix determined by signal recording process and crosstalk in the counter. Unknown parameters about the item are determined by the solutions of the equations. A {sup 252}Cf source and some low enriched uranium items have been measured. The feasibility of the method is proven by its application to the data analysis of the experiments.

  15. {sup 222}Rn determination in water and brine samples using liquid scintillation spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Thiago C.; Oliveira, Arno H., E-mail: oliveiratco2010@gmail.com [Universidade Federal de Minas Gerais (DEN/UFMG), Belo Horizonte (Brazil). Departamento de Engenharia Nuclear; Monteiro, Roberto P.G.; Moreira, Rubens M., E-mail: rpgm@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN-CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-07-01

    Liquid scintillation spectrometry (LSC) is the most common technique used for {sup 222}Rn determination in environmental aqueous sample. In this study, the performance of water-miscible (Ultima Gold AB) and immiscible (Optiscint) liquid scintillation cocktails has been compared for different matrices. {sup 241}Am, {sup 90}Sr and {sup 226}Ra standard solutions were used for LSC calibration. {sup 214}Po region was defined as better for both cocktails. Counting efficiency of 76 % and optimum PSA level of 95 for Ultima Gold AB cocktail, and counting efficiency of 82 % and optimum PSA level of 85 for Optiscint cocktail were obtained. Both cocktails showed similar results when applied for {sup 222}Rn activity determination in water and brine samples. However the Optiscint is recommended due to its quenching resistance. Limit of detection of 0.08 and 0.06 Bq l{sup -1} were obtained for water samples using a sample:cocktail ratio of 10:12 mL for Ultima Gold AB and Optiscint cocktails, respectively. Limit of detection of 0.08 and 0.04 Bq l{sup -1} were obtained for brine samples using a sample:cocktail ratio of 8:12 mL for Ultima Gold AB and Optiscint cocktails, respectively. (author)

  16. 222Rn determination in water and brine samples using liquid scintillation spectrometry

    International Nuclear Information System (INIS)

    Oliveira, Thiago C.; Oliveira, Arno H.

    2017-01-01

    Liquid scintillation spectrometry (LSC) is the most common technique used for 222 Rn determination in environmental aqueous sample. In this study, the performance of water-miscible (Ultima Gold AB) and immiscible (Optiscint) liquid scintillation cocktails has been compared for different matrices. 241 Am, 90 Sr and 226 Ra standard solutions were used for LSC calibration. 214 Po region was defined as better for both cocktails. Counting efficiency of 76 % and optimum PSA level of 95 for Ultima Gold AB cocktail, and counting efficiency of 82 % and optimum PSA level of 85 for Optiscint cocktail were obtained. Both cocktails showed similar results when applied for 222 Rn activity determination in water and brine samples. However the Optiscint is recommended due to its quenching resistance. Limit of detection of 0.08 and 0.06 Bq l -1 were obtained for water samples using a sample:cocktail ratio of 10:12 mL for Ultima Gold AB and Optiscint cocktails, respectively. Limit of detection of 0.08 and 0.04 Bq l -1 were obtained for brine samples using a sample:cocktail ratio of 8:12 mL for Ultima Gold AB and Optiscint cocktails, respectively. (author)

  17. Radioactivity measurement of barium carbonate [14C] by liquid scintillation counting

    International Nuclear Information System (INIS)

    Kobayashi, Katsutoshi; Hoizumi, Kiyoshi

    1985-03-01

    Two methods of sample preparation for the measurement of specific activity of BaCO 3 [ 14 C] by external standard method in liquid scintillation counting were studied. BaCO 3 [ 14 C] was decomposed by perchloric acid solution and generated CO 2 [ 14 C] was absorbed by ethylene glycol monomethyl ether solution of monoethanolamine as the method 1 or aqueous sodium hydroxide as the method 2. In order to prepare the sample solution of adequate radioactivity concentration, these carbonate solutions by the methods 1 and 2 were diluted with the suitable organic solvent and distilled water respectively. One tenth millilitre of these sample solutions was added into 10 ml of PPO-toluene scintillator containing 0.1 ml of monoethanolamine in a counting vial and homogeneously dissolved with ethyl alcohol. The results of the radioactivity measurement of BaCO 3 [ 14 C] based on the different method agreed within 5 % and the counting rate was found to be stable for as long as 7 deays or more. Both methods of preparation are suitable for the routine measurement because of their simplicity and feasibility. In the case of method 2, the liquid radioactive waste is almost inorganic solution and recovery in the form of BaCO 3 [ 14 C] is easily performed, so that this method is very advantageous from the view point of the radioactive waste treatement. (author)

  18. Preparation and performance study of a novel liquid scintillator with mixed solvent as the matrix

    International Nuclear Information System (INIS)

    Zheng, Zhanlong; Zhu, Jiayi; Luo, Xuan; Xu, Yewei; Zhang, Qianfeng; Zhang, Xing; Bi, Yutie; Zhang, Lin

    2017-01-01

    A novel liquid scintillator with the mixed solvent as the matrix was prepared for obtaining a good comprehensive performance. In this ternary liquid scintillator, the combination of 20% pseudocumene (PC) and 80% linear-alkyl benzene (LAB) by volume was chosen as the mixed solvent, and 2,5-diphenyloxazole (PPO) and 1,4-bis(2-Methylstyryl) benzene (bis-MSB) were as the primary fluor and wavelength shifter, respectively. The optimum prescription was obtained with regard to the light yield. Some characterizations based on the optimal formulation were conducted. The fluorescence emission spectra and wavelength-dependent optical attenuation length of the sample were measured by the fluorescence spectrophotometer and an UV–Vis spectrometer, respectively. The light yield was characterized by adopting the home-made optical platform device. The decay time was tested by adopting the time-correlated single photon counting (TCSPC) technique featured in high dynamic range of several orders of magnitude in light intensity. The experimental test results showed that the sample had a fairly good comprehensive performance.

  19. Optimised method for the routine determination of Technetium-99 in environmental samples by liquid scintillation counting

    International Nuclear Information System (INIS)

    Wigley, F.; Warwick, P.E.; Croudace, I.W.; Caborn, J.; Sanchez, A.L.

    1999-01-01

    A method has been developed for the routine determination of 99 Tc in a range of environmental matrices using 99m Tc (t 1/2 =6.06 h) as an internal yield monitor. Samples are ignited stepwise to 550C and the 99 Tc is extracted from the ignited residue with 8 M nitric acid. Many contaminants are co-precipitated with Fe(OH) 3 and the Tc in the supernatant is pre-concentrated and further purified using anion exchange chromatography. Final separation of Tc from Ru is achieved by extraction of Tc into 5% tri-n-octylamine in xylene from 2 M sulphuric acid. The xylene fraction is mixed directly with a commercial liquid scintillant cocktail. The chemical yield is determined through the measurement of 99m Tc by gamma spectrometry and the 99 Tc activity is measured using liquid scintillation counting after a further two weeks to allow decay of the 99m Tc activity. Typical recoveries for this method are in the order 70-95%. The method has a detection limit of 1.7 Bq kg -1 based on a 2 h count time and a 10 g sample size. The chemical separation for 24 samples of sediment or marine biota can be completed by one analyst in a working week. A further week is required to allow the samples to decay before determination. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)

  20. A dual-phase xenon TPC for scintillation and ionisation yield measurements in liquid xenon

    Science.gov (United States)

    Baudis, Laura; Biondi, Yanina; Capelli, Chiara; Galloway, Michelle; Kazama, Shingo; Kish, Alexander; Pakarha, Payam; Piastra, Francesco; Wulf, Julien

    2018-05-01

    A small-scale, two-phase (liquid/gas) xenon time projection chamber ( Xurich II) was designed, constructed and is under operation at the University of Zürich. Its main purpose is to investigate the microphysics of particle interactions in liquid xenon at energies below 50 keV, which are relevant for rare event searches using xenon as target material. Here we describe in detail the detector, its associated infrastructure, and the signal identification algorithm developed for processing and analysing the data. We present the first characterisation of the new instrument with calibration data from an internal ^83{m} Kr source. The zero-field light yield is 15.0 and 14.0 photoelectrons/keV at 9.4 and 32.1 keV, respectively, and the corresponding values at an electron drift field of 1 kV/cm are 10.8 and 7.9 photoelectrons/keV. The charge yields at these energies are 28 and 31 electrons/keV, with the proportional scintillation yield of 24 photoelectrons per one electron extracted into the gas phase, and an electron lifetime of 200 μ s. The relative energy resolution, σ /E, is 11.9 and 5.8% at 9.4 and 32.1 keV, respectively using a linear combination of the scintillation and ionisation signals. We conclude with measurements of the electron drift velocity at various electric fields, and compare these to literature values.

  1. Preparation and performance study of a novel liquid scintillator with mixed solvent as the matrix

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Zhanlong [Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang 621900 (China); School of Material Science and Engineering, Southwest University of Science and Technology, Mianyang 621010 (China); Joint Laboratory for Extreme Conditions Matter Properties, Southwest University of Science and Technology and Research Center of Laser Fusion, Mianyang 621010 (China); Zhu, Jiayi [Joint Laboratory for Extreme Conditions Matter Properties, Southwest University of Science and Technology and Research Center of Laser Fusion, Mianyang 621010 (China); Luo, Xuan, E-mail: luox76@gmail.com [Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang 621900 (China); Xu, Yewei [School of Material Science and Engineering, Southwest University of Science and Technology, Mianyang 621010 (China); Zhang, Qianfeng [Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang 621900 (China); Joint Laboratory for Extreme Conditions Matter Properties, Southwest University of Science and Technology and Research Center of Laser Fusion, Mianyang 621010 (China); Zhang, Xing [Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang 621900 (China); Bi, Yutie, E-mail: biyutie@sina.com [Joint Laboratory for Extreme Conditions Matter Properties, Southwest University of Science and Technology and Research Center of Laser Fusion, Mianyang 621010 (China); Zhang, Lin [Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang 621900 (China); School of Material Science and Engineering, Southwest University of Science and Technology, Mianyang 621010 (China); Joint Laboratory for Extreme Conditions Matter Properties, Southwest University of Science and Technology and Research Center of Laser Fusion, Mianyang 621010 (China)

    2017-04-01

    A novel liquid scintillator with the mixed solvent as the matrix was prepared for obtaining a good comprehensive performance. In this ternary liquid scintillator, the combination of 20% pseudocumene (PC) and 80% linear-alkyl benzene (LAB) by volume was chosen as the mixed solvent, and 2,5-diphenyloxazole (PPO) and 1,4-bis(2-Methylstyryl) benzene (bis-MSB) were as the primary fluor and wavelength shifter, respectively. The optimum prescription was obtained with regard to the light yield. Some characterizations based on the optimal formulation were conducted. The fluorescence emission spectra and wavelength-dependent optical attenuation length of the sample were measured by the fluorescence spectrophotometer and an UV–Vis spectrometer, respectively. The light yield was characterized by adopting the home-made optical platform device. The decay time was tested by adopting the time-correlated single photon counting (TCSPC) technique featured in high dynamic range of several orders of magnitude in light intensity. The experimental test results showed that the sample had a fairly good comprehensive performance.

  2. Apparent and actual 14C retention in the slower turnover bicarbonate pool in man when using liquid scintillation counting

    International Nuclear Information System (INIS)

    Clague, M.B.; Keir, M.J.; Clayton, C.B.

    1979-01-01

    The use of liquid scintillation counting to determine 14 CO 2 expiration without correct calibration of the apparatus suggests that about 25% of the label is retained within the slower turnover bicarbonate pool. Calibration reduces this figure to 13% and is in agreement with the figure obtained using a calibrated ionisation chamber. The discrepancy is due to reduction in the specific radioactivity in the vial, the mechanism involved being unknown, but it may be a characteristic of certain liquid scintillators under certain conditions. (author)

  3. Determination of low α activity levels applying a pulse discrimination system to a conventional liquid scintillation unit

    International Nuclear Information System (INIS)

    Oliveira, A.A.; Bonino, A.D.

    1983-01-01

    The described system allows the measurement of α activity in the presence of β/γ activities in various types of samples. Pulse shape discrimination of the signal from a conventional liquid scintillation unit is used for assessing the α activity in samples obtained from several radiochemical processes as well as in samples from area and surface monitoring, without separating for the γ and β emitters present. Additionally, the considerable background reduction attained by this method makes possible the utilization of automatic liquid scintillation systems for measuring enviromental and occupational monitoring samples. (Author) [es

  4. A comparison between the measurements of Kr-85 in environmental samples by liquid scintillation and proportional counters

    International Nuclear Information System (INIS)

    Heras Iniquez, M.C.; Perez Garcia, M.M.

    1983-01-01

    The most used methods for the measurement of Kr-81 beta-activity after their concentration and aisolation are the liquid scintillation counting and the proportional counter. In this work the beta activity of concentrated and aisolated Kr-85 samples measured in collaboration with the Max-Planck Institut fur Kernphyslk, Aussenstelle Freiburg. Samples taken both In Madrid and Frelburg are measured by proportional counters in the Max-Planck lnstitut, Freibury and by liquid scintillation counting in JEN, Madrid. The comparison of both measurements do not show appreciable discrepancy between the results obtained to both techniques. (Author)

  5. Role of quenching on alpha/beta separation in liquid scintillation counting for several high capacity cocktails

    International Nuclear Information System (INIS)

    Pujol, L.; Sanchez-Cabeza, J.-A.

    1997-01-01

    The optimization of alpha/beta separation in liquid scintillation using pulse shape analysis is convenient for the simultaneous determination of alpha and beta emitters in natural water and other samples. In this work, alpha/beta separation was studied for different scintillant/vial combinations and it was observed that both the optimum pulse shape discrimination level and the total interference value (that is, the summed relative interference between alpha and beta spectra) were dependent on the sample quenching and independent of the scintillant/vial combination. These results provide a simple method for modifying the counting configuration, such as a change in the cocktail, vial or sample characteristics, without the need to perform exhaustive parameter optimizations. Also, it was observed that, for our counting conditions, the combination of Ultima Gold AB scintillation cocktail with Zinsser low diffusion vials presented the lowest total interference, namely 0.94 ± 0.28%, which is insignificant for the counting of environmental samples. (Author)

  6. Response of gadolinium doped liquid scintillator to charged particles: measurement based on intrinsic U/Th contamination

    Science.gov (United States)

    Du, Q.; Lin, S. T.; He, H. T.; Liu, S. K.; Tang, C. J.; Wang, L.; Wong, H. T.; Xing, H. Y.; Yue, Q.; Zhu, J. J.

    2018-04-01

    A measurement is reported for the response to charged particles of a liquid scintillator named EJ-335 doped with 0.5% gadolinium by weight. This liquid scintillator was used as the detection medium in a neutron detector. The measurement is based on the in-situ α-particles from the intrinsic Uranium and Thorium contamination in the scintillator. The β–α and the α–α cascade decays from the U/Th decay chains were used to select α-particles. The contamination levels of U/Th were consequently measured to be (5.54±0.15)× 10‑11 g/g, (1.45±0.01)× 10‑10 g/g and (1.07±0.01)× 10‑11 g/g for 232Th, 238U and 235U, respectively, assuming secular equilibrium. The stopping power of α-particles in the liquid scintillator was simulated by the TRIM software. Then the Birks constant, kB, of the scintillator for α-particles was determined to be (7.28±0.23) mg/(cm2ṡMeV) by Birks' formulation. The response for protons is also presented assuming the kB constant is the same as for α-particles.

  7. Review of the evolution of safety, ecological and economical aspects of liquid scintillation counting materials and techniques

    International Nuclear Information System (INIS)

    Kalbhen, D.A.

    1983-01-01

    The wide applicability of liquid scintillation techniques for counting weak β-emitters and other radionuclides has led to the daily use of a large number of liquid scintillation counter instruments in research and control laboratories. Of the solvents used in liquid scintillators, xylene, toluene and trimethyl benzene are most common. To a minor extent, dioxane, methylglycol, ethanol and methanol are also used. The estimated annual total volume is around 2-3 million liters of scintillation cocktails. The present situation demonstrates a problem in laboratory safety and concomitant cost for waste treatment, usually not recognized. The use and handling of these inflammable and irritant solvents can induce certain risks to personnel and laboratory safety. A significant reduction of the ecological and health risks is important. In recent years, some progress has been made by using smaller volumes and smaller sizes of vials. The introduction of non-flammable scintillator solvents, which do not penetrate through polyethylene vials and do not escape into the laboratory atmosphere, also adds to the safety process

  8. Performance of two liquids scintillation and optimization of a Wallac 1411 counter in the tritium quantification in aqueous samples

    International Nuclear Information System (INIS)

    Contreras de la Cruz, E. de J.; Lopez del Rio, H.; Davila R, J. I.; Mireles G, F.; Pinedo V, J. L.

    2014-10-01

    The optimization of a liquid scintillation counting Wallac 1411 is presented as well as the performance of the liquids scintillation miscible in water OptiPhase Hi Safe 3 and Last Gold Ab, in the tritium quantification in aqueous samples. The luminescence effect, the quenching, the solution ph and the level of pulse amplitude comparator (Pac) were evaluated in the response of both liquids scintillation in the tritium measurement. The quenching and the luminescence modify the scintillators response; in the first of them the counting efficiency decreases and the minimum detectable activity increases; the second interferes in the tritium quantification in the interest window, but the effect disappears after 4 hours of darkness of the samples. The maximum counting efficiency was of 24% for OptiPhase Hi Safe 3 and 31% for Last Gold Ab, diminishing with the quenching until values of 8 and 11%, respectively. For a counting time of 6 hours and lower quenching, the minimum detectable concentration for OptiPhase Hi Safe 3 was of 13.4 ± 0.2 Bq/L and 9.9 ± 0.1 Bq/L for Last Gold Ab. Both scintillators responded appropriately to sour and basic solutions, being only presented chemiluminescence in Last Gold Ab to ph highly basic. The Pac application that varies between 1 and 256 does not have effect in the tritium measurement until values above 90. (Author)

  9. Liquid scintillators and liquefied rare gases for particle detectors. Background-determination in Double Chooz and scintillation properties of liquid argon

    International Nuclear Information System (INIS)

    Hofmann, Martin Alexander

    2012-01-01

    the BiPo analysis show the high level of radiopurity reached in Double Chooz. In addition, with the BiPo analysis the α-quenching factors for the Target and the GammaCatcher liquids have been determined, respectively, to 9.94±0.04 and 13.69±0.02 at 7.7 MeV, and 9.05±0.01 and 14.3±0.1 at 8.8 MeV. The former values show a good agreement with the values obtained in a dedicated laboratory measurement. The time stability of the peak position of the 214 Po α-peak could be proven, too, showing a stable detector performance at low visible energies. The direct search for Dark Matter can, amongst others, be performed with liquid rare gas detectors, which make use of the scintillation light. However, a good background discrimination is needed. Studies on the wavelength- and time-resolved scintillation properties of liquid argon have therefore been carried out with high resolution and best statistics. The results obtained for different ion beams show that particle discrimination is not feasible in any realistic experiment by means of the wavelength-resolved scintillation light only, but the time structure of the emitted light provides a good handle to distinguish between different incident particles. For heavy ions (sulfur) a ratio of the fast to the slow scintillation component of (1.6 ± 0.6) is found, while lighter particles (protons) exhibit a ratio of (0.25 ± 0.05). The outcome of the present studies shows that this ratio can also be used in wavelength-integrating measurements which have a comparable detection efficiency for wavelengths below and above ∝170 nm. The present results demonstrate that for a number of 90 detected photons the singlet-to-triplet distributions obtained for sulfur ions and protons as exciting particles cease to overlap. In a Dark Matter experiment, if all photons produced can be detected, this corresponds to a discrimination threshold of only 2.25 keV.

  10. Liquid scintillators and liquefied rare gases for particle detectors. Background-determination in Double Chooz and scintillation properties of liquid argon

    Energy Technology Data Exchange (ETDEWEB)

    Hofmann, Martin Alexander

    2012-11-27

    }(g)/(g)). Both gamma spectroscopy measurements and the BiPo analysis show the high level of radiopurity reached in Double Chooz. In addition, with the BiPo analysis the {alpha}-quenching factors for the Target and the GammaCatcher liquids have been determined, respectively, to 9.94{+-}0.04 and 13.69{+-}0.02 at 7.7 MeV, and 9.05{+-}0.01 and 14.3{+-}0.1 at 8.8 MeV. The former values show a good agreement with the values obtained in a dedicated laboratory measurement. The time stability of the peak position of the {sup 214}Po {alpha}-peak could be proven, too, showing a stable detector performance at low visible energies. The direct search for Dark Matter can, amongst others, be performed with liquid rare gas detectors, which make use of the scintillation light. However, a good background discrimination is needed. Studies on the wavelength- and time-resolved scintillation properties of liquid argon have therefore been carried out with high resolution and best statistics. The results obtained for different ion beams show that particle discrimination is not feasible in any realistic experiment by means of the wavelength-resolved scintillation light only, but the time structure of the emitted light provides a good handle to distinguish between different incident particles. For heavy ions (sulfur) a ratio of the fast to the slow scintillation component of (1.6 {+-} 0.6) is found, while lighter particles (protons) exhibit a ratio of (0.25 {+-} 0.05). The outcome of the present studies shows that this ratio can also be used in wavelength-integrating measurements which have a comparable detection efficiency for wavelengths below and above {proportional_to}170 nm. The present results demonstrate that for a number of 90 detected photons the singlet-to-triplet distributions obtained for sulfur ions and protons as exciting particles cease to overlap. In a Dark Matter experiment, if all photons produced can be detected, this corresponds to a discrimination threshold of only 2.25 keV.

  11. Ionic liquids as solvents for liquid scintillation technology. Čerenkov counting with 1-Butyl-3-Methylimidazolium Chloride

    International Nuclear Information System (INIS)

    Mirenda, Martín; Rodrigues, Darío; Arenillas, Pablo; Gutkowski, Karin

    2014-01-01

    We report the detection of the Čerenkov luminescence after the incorporation of a few droplets of a physiological solution of 2-deoxi-2( 18 F)fluorine-D-glucose into the ionic liquid 1-Butyl-3-Methylimidazolium Chloride (BmimCl). The phenomenon is attributed to the β + particles having energy above the threshold energy value for the Čerenkov radiation in this medium. The presence of another type of radiation that could eventually cause coincidences in the photodetectors was safely discarded. We show that this property serves to determine the activity of a 18 F solution by means of the novel TDCR–Čerenkov technique. The results were compared with those obtained from the classic TDCR scintillation method using a commercial scintillation cocktail. The activity values obtained from both methods were found to be virtually identical within the experimental uncertainties. The fact that high energy β particles in BmimCl generates Čerenkov photons makes this ionic liquid a promising compound for future research in detection and quantification of ionizing radiation, and it provides a potential alternative for applications in nuclear technology. - Highlights: • Čerenkov luminescence was detected when 18 F was dissolved in 1-Butyl-3-Methylimidazolium Chloride (BmimCl) ionic liquid. • The presence of another type of radiation that could eventually cause coincidences in the photodetectors was safely discarded. • Čerenkov luminescence serves to determine the activity of a 18 F solution by means of TDCR–Čerenkov technique. • Some advantages of the use of BmimCl as solvent for Čerenkov counting were listed

  12. QUENCH: A software package for the determination of quenching curves in Liquid Scintillation counting

    International Nuclear Information System (INIS)

    Cassette, Philippe

    2016-01-01

    In Liquid Scintillation Counting (LSC), the scintillating source is part of the measurement system and its detection efficiency varies with the scintillator used, the vial and the volume and the chemistry of the sample. The detection efficiency is generally determined using a quenching curve, describing, for a specific radionuclide, the relationship between a quenching index given by the counter and the detection efficiency. A quenched set of LS standard sources are prepared by adding a quenching agent and the quenching index and detection efficiency are determined for each source. Then a simple formula is fitted to the experimental points to define the quenching curve function. The paper describes a software package specifically devoted to the determination of quenching curves with uncertainties. The experimental measurements are described by their quenching index and detection efficiency with uncertainties on both quantities. Random Gaussian fluctuations of these experimental measurements are sampled and a polynomial or logarithmic function is fitted on each fluctuation by χ"2 minimization. This Monte Carlo procedure is repeated many times and eventually the arithmetic mean and the experimental standard deviation of each parameter are calculated, together with the covariances between these parameters. Using these parameters, the detection efficiency, corresponding to an arbitrary quenching index within the measured range, can be calculated. The associated uncertainty is calculated with the law of propagation of variances, including the covariance terms. - Highlights: • The program “QUENCH” is devoted to the interpolation of quenching curves in LSC. • Functions are fitted to experimental data with uncertainties in both quenching and efficiency. • The parameters of the fitting function and the associated covariance matrix are evaluated. • The detection efficiency and uncertainty corresponding to a given quenching index is calculated.

  13. Nd loaded liquid scintillator to search for 150Nd neutrinoless double beta decay

    International Nuclear Information System (INIS)

    Barabanov, I; Bezrukov, L; Yanovich, E; Cattadori, C; Danilov, N; Di Vacri, A; Ianni, A; Nisi, S; Ortica, F; Romani, A; Salvo, C; Smirnov, O

    2008-01-01

    The 150 Nd is considered one of the most attractive candidate for searching neutrinoless double beta (0νββ-) decay, thanks to its high Q-value (3.367 MeV), that makes the external background issue less significative respect to other isotopes, and favorable computed matrix elements. The isotopic abundance of this isotope in natural neodimium is only 5.6% and up to now, it has been investigated only in low mass experiments. The next step is to increase the sensitivity of the experiments using larger mass of neodymium (10 ton-1 kton). This could be possible with a Nd loaded liquid scintillator (LS). At the Gran Sasso National Laboratory (LNGS), a joint INFN (Istituto Nazionale di Fisica Nucleare) and INR (Institute for Nuclear Research of Moscow) working group has been carrying out since 2001 an R and D activity aiming to develop organic liquid scintillators (LS) doped with metals. The achieved know-how and the satisfactory results obtained both with In and Gd allowed to face the development and production of Nd doped LS. The development of metal doped LS is challenging because the metal has to be embedded in a proper organic system that makes it soluble in an organic solvent minimizing the impact of the metal-organic compound on the optical and scintillation properties of the LS. A further challenge in the case of Nd is the presence of absorption bands of this element in the optical region with a transparent region around 400 nm, which is about at the maximum of the scintillator emission spectrum. A 2.5 1 Nd loaded LS has been produced diluting an originally developed Nd-Carboxylic (Nd-CBX) salt in pseudocumene (PC), the solvent of the Borexino liquid scintillator. The measured light yield, at [Nd] = 6.5 g/1 and [PPO] = 1.5 g/1, is ∼ 75% of pure PC at the same fluor concentration (∼ 10000 ph/MeV). The Nd doped LS has been tested in a 2 1 quartz cell (wrapped by VM2000 reflector film) having dimensions 5x5x100 cm 3 . The light propagates in the cell by total

  14. A liquid scintillation counter specifically designed for samples deposited on a flat matrix

    International Nuclear Information System (INIS)

    Potter, C.G.; Warner, G.T.

    1986-01-01

    A prototype liquid scintillation counter has been designed to count samples deposited as a 6x16 array on a flat matrix. Applications include the counting of labelled cells processed by a cell harvester from 96-well microtitration plates onto glass fibre filters and of DNA samples directly deposited onto nitrocellulose or nylon transfer membranes (e.g. 'Genescreen' NEN) for genetic studies by dot-blot hybridisation. The whole filter is placed in a bag with 4-12 ml of scintillant, sufficient to count all 96 samples. Nearest-neighbour intersample cross talk ranged from 0.004% for 3 H to 0.015% for 32 P. Background was 1.4 counts/min for glass fibre and 0.7 counts/min for 'Genescreen' in the 3 H channel: for 14 C the respective figures were 5.3 and 4.3 counts/min. Counting efficiency for 3 H-labelled cells on glass fibre was 54%(E 2 /B=2053) and 26% for tritiated thymidine spotted on 'Genescreen'(E 2 /B=980). Similar 14 C samples gave figures on 97%(E 2 /B=1775) and 81(E 2 B=1526) respectively. Electron emission counting from samples containing 125 I and 51 Cr was also possible. (U.K.)

  15. Use of liquid scintillation counting for quantitative analysis of volatile organic compounds in batch isotherm analysis

    International Nuclear Information System (INIS)

    Wickman, D.C.

    1987-01-01

    An estimate of how rapidly hazardous wastes move through subsurface soils via ground water is important to predict the location and concentration of the contaminant plume vs. time. The contaminated ground water system may be viewed as an HPLC column with the organic components of the waste in adsorption/desorption equilibrium with the subsurface soil. The batch isotherm method was chosen to determine the equilibrium constant between trichloroethylene, o-dichlorobenzene, 1-methyl naphthalene and aquifer materials obtained from various locations around the country. Liquid Scintillation counting has been found to be an excellent technique for batch isotherm analysis; using 14C labeled compounds, it affords unattended analysis, accuracy at very low concentrations and rapid data reduction. Ten ml serum containing about 5 ml water and a known weight of soil (approximately 2 grams) were spiked with the labeled solution to yield organic solute concentrations in the range of 0.02-1.0 mg/1. Six different concentrations were used. After spiking, the bottles were filled to the top with water and crimp sealed with teflon coated septa. All soil containing bottles were then rotated at 50 rpm and 22 degrees Celsius. Twenty-four hours later the bottles were uncapped and a 1.4 ml aliquot was removed and placed in scintillation cocktail and counted

  16. Determination of 226Ra and 224Ra in sediments samples by liquid scintillation counting

    International Nuclear Information System (INIS)

    Villa, M.; Moreno, H.P.; Manjon, G.

    2005-01-01

    An experimental procedure has been developed for a rapid determination of the activity concentration of 226 Ra and 224 Ra in sediments by liquid scintillation counting. The importance of the method lies in its application to the measurement of sediments where the Ra-isotopes activity concentration has been increased due to an anthropomorphic enhancement based on releases of naturally occurring radioactive material (NORM). A sample pre-treatment, including a digestion with aqua regia and a precipitation of hydroxides, was applied to samples before the radium extraction, which was made by co-precipitation with barium. Measurements were done in a low background scintillation spectrometer Quantulus 1220, which can separate and detect simultaneously α and β particles. Additionally, some improvements are suggested for a better α and β interference correction of the results. The obtaining of radiochemical yields is also improved using 133 Ba as tracer, which decays by emission of conversion electrons and γ-rays; the wide range of radiochemical yields obtained confirms the need of this analyses. The procedure has been applied to the measurement of riverbed sediments from an estuary in the south-west of Spain, affected in the past by direct and indirect phosphogypsum discharges

  17. Combustion water purification techniques influence on OBT analysing using liquid scintillation counting method

    Energy Technology Data Exchange (ETDEWEB)

    Varlam, C.; Vagner, I.; Faurescu, I.; Faurescu, D. [National Institute for Cryogenics and Isotopic Technologies, Valcea (Romania)

    2015-03-15

    In order to determine organically bound tritium (OBT) from environmental samples, these must be converted into water, measurable by liquid scintillation counting (LSC). For this purpose we conducted some experiments to determine OBT level of a grass sample collected from an uncontaminated area. The studied grass sample was combusted in a Parr bomb. However usual interfering phenomena were identified: color or chemical quench, chemiluminescence, overlap over tritium spectrum because of other radionuclides presence as impurities ({sup 14}C from organically compounds, {sup 36}Cl as chloride and free chlorine, {sup 40}K as potassium cations) and emulsion separation. So the purification of the combustion water before scintillation counting appeared to be essential. 5 purification methods were tested: distillation with chemical treatment (Na{sub 2}O{sub 2} and KMnO{sub 4}), lyophilization, chemical treatment (Na{sub 2}O{sub 2} and KMnO{sub 4}) followed by lyophilization, azeotropic distillation with toluene and treatment with a volcanic tuff followed by lyophilization. After the purification step each sample was measured and the OBT measured concentration, together with physico-chemical analysis of the water analyzed, revealed that the most efficient method applied for purification of the combustion water was the method using chemical treatment followed by lyophilization.

  18. Standardization of a 89Sr solution from a BIPM intercomparison using a liquid scintillation method

    International Nuclear Information System (INIS)

    Cruz, P.A.L.; Loureiro, J.S.; Bernardes, E.M.O.

    2002-01-01

    A procedure to standardize 89 Sr (as strontium chloride) solutions, within the frame of a BIPM intercomparison, by the CIEMAT/NIST method was presented for Instagel Plus, HiSafe III and Ultima Gold liquid scintillation cocktails. The stability was studied for two types of samples: those obtained by direct addition of the 89 Sr solution and those by the extra addition of 0.5 ml of HCl (0.1 mol l -1 ) to the cocktails. The results only showed good stability with the three scintillants used when additional HCl was added to the cocktails. The activities per unit mass determined for 89 Sr were: 26.344 kBq g -1 for Instagel Plus; 26.335 kBq g -1 for HiSafe III; and 26.310 kBq g -1 for Ultima Gold (at a reference time of 2000.10.01, 00 h UT) with a total uncertainty of 0.5% in each case (k=1)

  19. Combustion water purification techniques influence on OBT analysing using liquid scintillation counting method

    International Nuclear Information System (INIS)

    Varlam, C.; Vagner, I.; Faurescu, I.; Faurescu, D.

    2015-01-01

    In order to determine organically bound tritium (OBT) from environmental samples, these must be converted into water, measurable by liquid scintillation counting (LSC). For this purpose we conducted some experiments to determine OBT level of a grass sample collected from an uncontaminated area. The studied grass sample was combusted in a Parr bomb. However usual interfering phenomena were identified: color or chemical quench, chemiluminescence, overlap over tritium spectrum because of other radionuclides presence as impurities ( 14 C from organically compounds, 36 Cl as chloride and free chlorine, 40 K as potassium cations) and emulsion separation. So the purification of the combustion water before scintillation counting appeared to be essential. 5 purification methods were tested: distillation with chemical treatment (Na 2 O 2 and KMnO 4 ), lyophilization, chemical treatment (Na 2 O 2 and KMnO 4 ) followed by lyophilization, azeotropic distillation with toluene and treatment with a volcanic tuff followed by lyophilization. After the purification step each sample was measured and the OBT measured concentration, together with physico-chemical analysis of the water analyzed, revealed that the most efficient method applied for purification of the combustion water was the method using chemical treatment followed by lyophilization

  20. Results from a new combined test of an electromagnetic liquid argon calorimeter with a hadronic scintillating-tile calorimeter

    Czech Academy of Sciences Publication Activity Database

    Akhmadaliev, S.; Albiol, F.; Amaral, P.; Lokajíček, Miloš; Němeček, Stanislav

    2000-01-01

    Roč. 449, - (2000), s. 461-477 ISSN 0168-9002 R&D Projects: GA MPO RP-4210/69 Institutional research plan: CEZ:AV0Z1010920 Keywords : liquid argon * calorimeter * hadronic scintillating- tile * CERN SPS * ATLAS * LHC * energy resolution * pions Subject RIV: BF - Elementary Particles and High Energy Physics Impact factor: 0.964, year: 2000

  1. Performances and stability of a 2.4 ton Gd organic liquid scintillator target for ν-bar e detection

    International Nuclear Information System (INIS)

    Barabanov, I R; Bezrukov, L B; Danilov, N A; Krilov, Yu S; Yanovich, E A; Malguin, A S; Cattadori, C M; Vacri, A di; Ioannucci, L; Bruno, G; Aglietta, M; Bonardi, A; Fulgione, W; Porta, A; Kemp, E; Selvi, M

    2010-01-01

    In this paper we report the performance and the chemical and physical properties of a 2 x 1.2 ton organic liquid scintillator target doped with Gd up to ∼ 0.1%, and the results of a 3 year long stability survey of the target. In particular we have measured and monitored the optical and fluorescent properties of the Gd-doped liquid scintillator (LS), the amount of both Gd and primary fluor in solution, and the performance of the two Gd doped targets as neutron detectors, namely neutron capture efficiency and average capture time. The experimental survey is ongoing, the targets being continuously monitored. From the spectrophotometric measurements performed on samples periodically extracted along the three years, we can exclude, at 99% C.L. level, a degradation of the light transmittance of the Gd-doped liquid scintillator larger than 1% y -1 ; from the in-tank measurements no significant decrease of the neutron capture efficiency and neutron capture time is observed. This is the largest stable Gd-doped organic liquid scintillator target ever produced and continuously operated for a long period.

  2. Scintillating liquid xenon calorimeter for precise electron/photon/jet physics at high energy high luminosity hadron colliders

    International Nuclear Information System (INIS)

    Chen, M.; Luckey, D.; Pelly, D.; Shotkin, S.; Sumorok, K.; Wadsworth, B.; Yan, X.J.; You, C.; Zhang, X.; Chen, E.G.; Gaudreau, M.P.J.; Montgomery, D.B.; Sullivan, J.D.; Bolozdynya, A.; Chernyshev, V.; Goritchev, P.; Khovansky, V.; Kouchenkov, A.; Kovalenko, A.; Lebedenko, V.; Vinogradov, V.A.; Epstein, V.; Zeldovich, S.; Krasnokutsky, R.; Shuvalov, R.; Aprile, E.; Mukherjee, R.; Suzuki, M.; Moulsen, M.; Sugimoto, S.; Okada, K.; Fujino, T.; Matsuda, T.; Miyajima, M.; Doke, T.; Kikuchi, J.; Hitachi, A.; Kashiwagi, T.; Nagasawa, Y.; Ichinose, H.; Ishida, N.; Nakasugi, T.; Ito, T.; Masuda, K.; Shibamura, E.; Wallraff, W.; Vivargent, M.; Mutterer, M.; Chen, H.S.; Tang, H.W.; Tung, K.L.; Ding, H.L.; Takahashi, T.

    1990-01-01

    The authors use αs well as e, π, p, d and heavy ion beams to test prototype scintillating liquid xenon detectors, with large UV photodiodes and fast amplifiers submersed directly in liquid xenon. The data show very large photoelectron yields (10 7 /GeV) and high energy resolution (σ(E)/E 1.6 GeV). The α spectra are stable over long term and can be used to calibrate the detectors. Full size liquid xenon detectors have been constructed, to study cosmic μ's and heavy ions. The authors report the progress on the design and construction of the 5 x 5 and 11 x 11 cell liquid xenon detectors which will be tested in high energy beams to determine the e/π ratio. The authors describe the design and the unique properties of the proposed scintillating LXe calorimeter for the SSC

  3. Low energy neutrino astrophysics with the large liquid-scintillator detector LENA

    International Nuclear Information System (INIS)

    Wurm, M.; Feilitzsch, F. von; Goeger-Neff, M.; Undagoitia, T. Marrodan; Oberauer, L.; Potzel, W.; Winter, J.

    2007-01-01

    The large-volume liquid-scintillator detector LENA (Low Energy Neutrino Astronomy) will cover a broad field of physics. Apart from the detection of terrestrial and artificial neutrinos, and the search for proton decay, important contributions can be made to the astrophysics of stars by high-precision spectroscopy of low-energetic solar neutrinos and by the observation of neutrinos emitted by a galactic supernova. Moreover, the detection of the diffuse supernova neutrino background in LENA will offer the opportunity of studying both supernova core-collapse models and the supernova rate on cosmological timescales (z e events in an almost background-free energy window from ∼10 to 25 MeV. The search for such rare low-energetic events takes advantage of the high energy resolution and excellent background rejection possible in the LENA detector

  4. Digital discrimination of neutrons and γ-rays in liquid scintillators using pulse gradient analysis

    International Nuclear Information System (INIS)

    D'Mellow, B.; Aspinall, M.D.; Mackin, R.O.; Joyce, M.J.; Peyton, A.J.

    2007-01-01

    A method for the digital discrimination of neutrons and γ-rays in mixed radiation fields is described. Pulses in the time domain, arising from the interaction of photons and neutrons in a liquid scintillator, have been produced using an accepted empirical model and from experimental measurements with an americium-beryllium source. Neutrons and γ-rays have been successfully discriminated in both of these data sets in the digital domain. The digital discrimination method described in this paper is simple and exploits samples early in the life of the pulse. It is thus compatible with current embedded system technologies, offers a degree of immunity to pulse pile-up and heralds a real-time means for neutron/γ discrimination that is fundamental to many potential industrial applications

  5. Charged particle identification including Pions by pulse-shape discrimination with an NE213 liquid scintillator

    International Nuclear Information System (INIS)

    Nakamoto, T.; Ishibashi, K.; Matsufuji, N.; Shigyo, N.; Maehata, K.

    1995-01-01

    Particles emitted from spallation reactions induced by protons having GeV energies were measured with an NE213 liquid scintillator, 12.7 cm in diameter and 12.7 cm thick. The pulse-shape discrimination (PSD) was carried out for charged particle identification by the two-gate integration method. Pions having energies up to 60 MeV were clearly discriminated from protons and electrons. On the contrary, pions with higher energies could not be identified since they escaped from the detector. The advantage of PSD for charged particle identification is that there is no requirement for a ΔE detector in the measurements. copyright 1995 American Institute of Physics

  6. Usage of liquid scintillation counting for detecting the chemiluminescence of cells and its application in medicine

    International Nuclear Information System (INIS)

    Li Tianxing; Liang Qizhong; Zou Xiaowei; Yang Zhaohen; Huang Yong; Li Huaqiang

    1995-01-01

    The liquid scintillator counting-chemiluminescence (LSC-CL) of mono-photon radiance is a sensitive, handy and high-autoanalytic technique. Through measuring basic CL, dependent CL and maximum phagocytic CL of polymorphonuclear (PMN), we studied best factor levels of the method with orthogonal design [L 9 (3 4 )]. The results showed the peak forms changed markedly (inter-group P -4 M). PMN-CL in blood was measured during acute attack of the old patients with chronic bronchitis and the children with pneumonia bronchial. It was suggested that PMN phagocytosis decreased. So the dynamic analysis of maximum phagocytic CL would help us with the deep going clinical researches of the mechanisms of anti-inflammation and injuring by the oxygen free radicals

  7. Standardization of Ga-68 by coincidence measurements, liquid scintillation counting and 4πγ counting.

    Science.gov (United States)

    Roteta, Miguel; Peyres, Virginia; Rodríguez Barquero, Leonor; García-Toraño, Eduardo; Arenillas, Pablo; Balpardo, Christian; Rodrígues, Darío; Llovera, Roberto

    2012-09-01

    The radionuclide (68)Ga is one of the few positron emitters that can be prepared in-house without the use of a cyclotron. It disintegrates to the ground state of (68)Zn partially by positron emission (89.1%) with a maximum energy of 1899.1 keV, and partially by electron capture (10.9%). This nuclide has been standardized in the frame of a cooperation project between the Radionuclide Metrology laboratories from CIEMAT (Spain) and CNEA (Argentina). Measurements involved several techniques: 4πβ-γ coincidences, integral gamma counting and Liquid Scintillation Counting using the triple to double coincidence ratio and the CIEMAT/NIST methods. Given the short half-life of the radionuclide assayed, a direct comparison between results from both laboratories was excluded and a comparison of experimental efficiencies of similar NaI detectors was used instead. Copyright © 2012 Elsevier Ltd. All rights reserved.

  8. Standardization of 241Am by digital coincidence counting, liquid scintillation counting and defined solid angle counting

    International Nuclear Information System (INIS)

    Balpardo, C.; Capoulat, M.E.; Rodrigues, D.; Arenillas, P.

    2010-01-01

    The nuclide 241 Am decays by alpha emission to 237 Np. Most of the decays (84.6%) populate the excited level of 237 Np with energy of 59.54 keV. Digital coincidence counting was applied to standardize a solution of 241 Am by alpha-gamma coincidence counting with efficiency extrapolation. Electronic discrimination was implemented with a pressurized proportional counter and the results were compared with two other independent techniques: Liquid scintillation counting using the logical sum of double coincidences in a TDCR array and defined solid angle counting taking into account activity inhomogeneity in the active deposit. The results show consistency between the three methods within a limit of a 0.3%. An ampoule of this solution will be sent to the International Reference System (SIR) during 2009. Uncertainties were analysed and compared in detail for the three applied methods.

  9. Characterization of liquid scintillation detector (BC-501A) and digital pulse shape discrimination (DPSD) system

    Energy Technology Data Exchange (ETDEWEB)

    Lombigit, L., E-mail: lojius@nm.gov.my; Yussup, N., E-mail: nolida@nm.gov.my; Ibrahim, Maslina Mohd; Rahman, Nur Aira Abd; Rawi, M. Z. M. [Instrumentation Group, Malaysian Nuclear Agency, Bangi, 43000 Kajang, Selangor (Malaysia)

    2015-04-29

    A digital n/γ pulse shape discrimination (PSD) system is currently under development at Instrumentation and Automation Centre, Malaysian Nuclear Agency. This system aims at simultaneous detection of fast neutron and gamma ray in mixed radiations environment. This work reports the system characterization performed on the liquid scintillation detector (BC-501A) and digital pulse shape discrimination (DPSD) system. The characterization involves measurement of electron light output from the BC-501A detector and energy channels calibration of the pulse height spectra acquired with DPSD system using set of photon reference sources. The main goal of this experiment is to calibrate the ADC channel of our DPSD system, characterized the BC-501 detector and find the position of Compton edge which later could be used as threshold for the n/γ PSD experiment. The detector resolution however is worse as compared to other published data but it is expected as our detector has a smaller active volume.

  10. Radium 226 and uranium isotopes simultaneously determination in water samples using liquid scintillation counter

    International Nuclear Information System (INIS)

    Al-Masri, M.S.; Al-Akel, B.; Saaid, S.; Nashawati, A.

    2007-04-01

    In this work a method has been developed to determine simultaneously Radium 226 and Uranium isotopes in water samples by low back ground Liquid Scintillation Counter. Radium 226 was determined by its progeny Polonium 214 after one month of sample storage in order to achieve the equilibrium between Radium 226 and Polonium 214. Uranium isotopes were determined by subtracting Radium 226 activity from total alpha activity. The method detection limits were 0.049 Bq/L and 0.176 Bq/L for Radium 226 and Uranium isotopes respectively. The repeatability limits were ± 0.32 Bq/L and ± 0.9 Bq/L for Radium 226 and Uranium isotopes respectively. While relative errors were % 9.5 and %18.2 for Radium 226 and Uranium isotopes respectively. On the other hand, the report presented the results of different standard and natural samples.(author)

  11. High Resolution Tracking Devices Based on Capillaries Filled with Liquid Scintillator

    CERN Multimedia

    Bonekamper, D; Vassiltchenko, V; Wolff, T

    2002-01-01

    %RD46 %title\\\\ \\\\The aim of the project is to develop high resolution tracking devices based on thin glass capillary arrays filled with liquid scintillator. This technique provides high hit densities and a position resolution better than 20 $\\mu$m. Further, their radiation hardness makes them superior to other types of tracking devices with comparable performance. Therefore, the technique is attractive for inner tracking in collider experiments, microvertex devices, or active targets for short-lived particle detection. High integration levels in the read-out based on the use of multi-pixel photon detectors and the possibility of optical multiplexing allow to reduce considerably the number of output channels, and, thus, the cost for the detector.\\\\ \\\\New optoelectronic devices have been developed and tested: the megapixel Electron Bombarded CCD (EBCCD), a high resolution image-detector having an outstanding capability of single photo-electron detection; the Vacuum Image Pipeline (VIP), a high-speed gateable pi...

  12. Study of a system for tritium analysis in water by electrolytic enrichment and liquid scintillation

    International Nuclear Information System (INIS)

    Pane, L.

    1979-01-01

    A system for the measurement of the low-level tritium concentrations in water samples has been experimentally studied. The enrichment of the samples is performed through electrolysis in twenty cells connected in series, and the counting is made in a liquid scintillation counter. Several parameters that could affect the accuracy of the results are analysed and the optimization of the system is discussed. For a sample volume reduction from 1000 to 15ml, the recovery of tritium, during electrolysis is of 63% and the enrichment factor is about 40. The lowest detection limit of the system is 1.0+-0.5 U.T. Its analytical capacity is of 30 samples a month. The results obtained in the determination of 3 H concentration in a series of samples from rain, surface and underground waters can be considered satisfactory. (Author) [pt

  13. Rapid bioassay method for estimation of 90Sr in urine samples by liquid scintillation counting

    International Nuclear Information System (INIS)

    Wankhede, Sonal; Chaudhary, Seema; Sawant, Pramilla D.

    2018-01-01

    Radiostrontium (Sr) is a by-product of the nuclear fission of uranium and plutonium in nuclear reactors and is an important radionuclide in spent nuclear fuel and radioactive waste. Rapid bioassay methods are required for estimating Sr in urine following internal contamination. Decision regarding medical intervention, if any can be based upon the results of urinalysis. The present method used at Bioassay Laboratory, Trombay is by Solid Extraction Chromatography (SEC) technique. The Sr separated from urine sample is precipitated as SrCO 3 and analyzed gravimetrically. However, gravimetric procedure is time consuming and therefore, in the present study, feasibility of Liquid Scintillation Counting for direct detection of radiostrontium in effluent was explored. The results obtained in the present study were compared with those obtained using gravimetric method

  14. Standardization of method to determine 241Pu in urine samples by liquid scintillation analyzer

    International Nuclear Information System (INIS)

    Raveendran, Nanda; Rao, D.D.; Yadav, J.R.; Baburajan, A.

    2015-01-01

    As a part of radiation protection programme, occupational workers of fuel reprocessing plant are checked for internal contamination by analyzing urine samples periodically. Urine samples are analyzed to determine 239+240 Pu and 238 Pu by using standard conventional method and are counted by alpha spectrometry. 241 Pu is also one of the contaminant present in the urine sample of radiation workers. It is a low beta emitter with E max 21 keV. A methodology for the determination of this nuclide was standardized by using radiochemical analysis followed by Liquid Scintillation Counting. The method was tested and found suitable for the determination of 241 Pu in urine sample for the assessment of Committed Effective Dose (CED). (author)

  15. A methodology for the optimization of the estimation of tritium in urine by liquid scintillation counting

    International Nuclear Information System (INIS)

    Joseph, S.; Kramer, G.H.

    1982-10-01

    A method has been designed to optimize liquid scintillation (LS) urinalysis with respect to sensitivity and cost. Three related factors, quench, sample composition and counting efficiency, were measured simultaneously and the results plotted in three dimensions to determine the optimum conditions for urinalysis. Picric acid was used to simulate quenching. Subsequent urinalysis experiments showed that quenching by picric acid was analogous to urine quenching. The optimization methodology was applied to ten commercial LS cocktails and a wide divergence in results was obtained. This method can also be used to optimize minimum detectable activities (MDA) but the results show that there is no fixed sample composition that can be used for all the various types of urine samples; however, it is possible to achieve general improvements of at least a factor of 2 in the MDA for Scintiverse (the only one tested for this particular application of the methodology)

  16. Processing of liquid scintillation nuclear spectra for unquenched and quenched sources

    International Nuclear Information System (INIS)

    Madan, V.K.; Gopalakrishnan, K.R.

    1997-01-01

    This paper describes a nuclear (beta) spectral analysis method for qualitative and quantitative analysis of radioactivity for use in a liquid scintillation counting system. It is based on computing a spectral index number (SIN) for qualitative analysis of an unquenched sample. For quantitative analysis it was proposed that a complementary nonlinear function be estimated between efficiency and SIN from a standard set of samples. It reduces the computational burden. An unknown sample is analyzed by computing its SIN and that is used to calculate efficiency using the function to facilitate quantitative analysis. A software was developed and verified on real spectra of radioisotopes. The paper presents the method and its application with results. (author). 5 refs

  17. Characterization of liquid scintillation detector (BC-501A) and digital pulse shape discrimination (DPSD) system

    International Nuclear Information System (INIS)

    Lombigit, L.; Yussup, N.; Ibrahim, Maslina Mohd; Rahman, Nur Aira Abd; Rawi, M. Z. M.

    2015-01-01

    A digital n/γ pulse shape discrimination (PSD) system is currently under development at Instrumentation and Automation Centre, Malaysian Nuclear Agency. This system aims at simultaneous detection of fast neutron and gamma ray in mixed radiations environment. This work reports the system characterization performed on the liquid scintillation detector (BC-501A) and digital pulse shape discrimination (DPSD) system. The characterization involves measurement of electron light output from the BC-501A detector and energy channels calibration of the pulse height spectra acquired with DPSD system using set of photon reference sources. The main goal of this experiment is to calibrate the ADC channel of our DPSD system, characterized the BC-501 detector and find the position of Compton edge which later could be used as threshold for the n/γ PSD experiment. The detector resolution however is worse as compared to other published data but it is expected as our detector has a smaller active volume

  18. Correlation among the spectral parameters for qualitative analysis of Alpha Liquid Scintillation Spectra

    International Nuclear Information System (INIS)

    Bhade, Sonali P.D.; Reddy, P.J.; Kolekar, R.V.; Singh, Rajvir; Pradeepkumar, K.S.

    2014-01-01

    The potential use of alpha LSC technique is nowadays recognized widely. However the energy resolution of α particle is poor with liquid scintillators. Moreover, α peak positions are influenced by the level of quenching in the samples. To overcome this problem, a thorough study of all concerned parameters that affect spectral information was carried out. The parameters such as peak's centroid, quenching, % resolution, energy of α particle were investigated and the correlation between them was evaluated. In the present work, the qualitative analysis of α spectrum was carried out. Correlations between the energy of α particle and various parameters affecting the peaks of the collected spectra with respect to quenching were established. These correlations will be useful for the deconvolution studies of composite samples containing different alpha radionuclides

  19. Experimental results from a large volume active target made of glass capillaries and liquid scintillator

    International Nuclear Information System (INIS)

    Annis, P.; Buontempo, S.; Brunner, J.; De Jong, M.; Fabre, J.P.; Frenkel, A.; Galeazzi, F.; Golovkin, S.; Gregoire, G.; Hoepfner, K.; Konijn, J.; Kozarenko, E.; Kreslo, I.; Kushnirenko, A.; Martellotti, G.; Mazzoni, M.A.; Medvedkov, A.; Michel, L.; Mondardini, M.R.; Panman, J.; Penso, G.; Petukhov, Y.; Riccardi, F.; Siegmund, W.P.; Strack, R.; Tyukov, V.; Vasilchenko, V.; Vilain, P.; Wilquet, G.; Winter, K.; Wong, H.; Zymin, K.

    1995-01-01

    We are investigating the feasibility of high-resolution tracking with an active target made of glass capillaries filled with organic liquid scintillator. This technique allows real time detection of short-lived particle decays. In this paper, we report on experimental results obtained from an active target having 2 x 2 cm 2 cross section and 180 cm length, installed in front of the CHORUS detector and exposed to the CERN Wide Band Neutrino Beam. The detector consists of 5.1 x 10 5 capillaries with 20 μm inner diameter, read out by a single optoelectronic chain and a Megapixel CCD. Details on tests in the neutrino beam will be reported. First neutrino interactions have been detected. (orig.)

  20. Calibration of a liquid scintillation counter to assess tritium levels in various samples

    CERN Document Server

    Al-Haddad, M N; Abu-Jarad, F A

    1999-01-01

    An LKB-Wallac 1217 Liquid Scintillation Counter (LSC) was calibrated with a newly adopted cocktail. The LSC was then used to measure tritium levels in various samples to assess the compliance of tritium levels with the recommended international levels. The counter was calibrated to measure both biological and operational samples for personnel and for an accelerator facility at KFUPM. The biological samples include the bioassay (urine), saliva, and nasal tests. The operational samples of the light ion linear accelerator include target cooling water, organic oil, fomblin oil, and smear samples. Sets of standards, which simulate various samples, were fabricated using traceable certified tritium standards. The efficiency of the counter was obtained for each sample. The typical range of the efficiencies varied from 33% for smear samples down to 1.5% for organic oil samples. A quenching curve for each sample is presented. The minimum detectable activity for each sample was established. Typical tritium levels in bio...

  1. Ultra Low Level Tritium Analysis Method Using a Liquid Scintillation Counter

    Energy Technology Data Exchange (ETDEWEB)

    Noh, S. J.; Kim, H. J.; Kim, H.; Lim, H. J.; Lee, M. W.; Jeong, D. H.; Kim, J. K.; Kang, Y. R. [Dongnam Institute of Radiological and Medical Sciences, Busan (Korea, Republic of); Nam, S. H. [Inje University, Gimhae, (Korea, Republic of)

    2015-05-15

    To evaluate {sup 3}H concentration in the atmosphere more accurately compared to the conventional methods, the author of this paper intended to suggest more improved analytical methods and derived the elements which might occur during analysis or required improvements. The method suggested in this study is able to reduce the uncertainty and errors which may be existent in evaluating the {sup 3}H concentration of environmental sample s and thus will serve as the best solution in the technical and economic point of view. Liquid Scintillation Counter is the most widely used to analyze ultra-low level {sup 3}H by using CPM / DPM Counting Mode using external radiation source and Spectrum Plot Mode using internal radiation source. In CPM / DPM Counting Mode, multiple samples can be measured by single calibration despite its rather higher background whereas Spectrum Plot Mode requires more time and cost to analyze multiple samples despite its reliability to reduce the contribution of other radionuclides.

  2. Determination of radon concentration in ground water in Aichi Prefecture by liquid scintillation counter

    Energy Technology Data Exchange (ETDEWEB)

    Onuma, A.; Shimizu, M.; Chaya, K.; Hamamura, N. (Aichi Prefectural Inst. of Public Health, Nagoya (Japan)); Kagami, T.

    1982-01-01

    The radon (Rn) concentration in ground water in Aichi Prefecture was determined by the liquid scintillation counter (LSC) method. The measurement of radon by LSC was made by integration counting, keeping the constant LS quantity in a vial and the constant geometry of a photomultiplier. The recovery rate of radon with 226-radium standard solution was 98.7%. The coefficient of variation in the measured values of radon concentration in ground water in Aichi Prefecture by the LSC method was 4.9%. For the same ground waters in the prefecture, the radon concentrations measured by the LSC method and by the conventional IM fontactoscope method were examined comparatively. This gave a regression formula of LSC value = 0.583 x IM value + 1.325 (n = 70, coefficient of correlation 0.966), indicating significant correlation between the two. It is thus shown that the LSC method is an effective means as the IM fontactoscope method.

  3. Determination of radon concentration in ground water in Aichi Prefecture by liquid scintillation counter

    International Nuclear Information System (INIS)

    Onuma, Akiko; Shimizu, Michihiko; Chaya, Kunio; Hamamura, Norikatsu; Kagami, Tadaaki.

    1982-01-01

    The radon (Rn) concentration in ground water in Aichi Prefecture was determined by the liquid scintillation counter (LSC) method. The measurement of radon by LSC was made by integration counting, keeping the constant LS quantity in a vial and the constant geometry of a photomultiplier. The recovery rate of radon with 226-radium standard solution was 98.7%. The coefficient of variation in the measured values of radon concentration in ground water in Aichi Prefecture by the LSC method was 4.9%. For the same ground waters in the prefecture, the radon concentrations measured by the LSC method and by the conventional IM fontactoscope method were examined comparatively. This gave a regression formula of LSC value = 0.583 x IM value + 1.325 (n = 70, coefficient of correlation 0.966), indicating significant correlation between the two. It is thus shown that the LSC method is an effective means as the IM fontactoscope method. (J.P.N.)

  4. Tritium Activity Measurement of Water Samples Using Liquid Scintillation Counter and Electrolytical Enrichment

    International Nuclear Information System (INIS)

    Baresic, J.; Krajcar Bronic, I.; Horvatincic, N.; Obelic, B.; Sironic, A.; Kozar-Logar J.

    2011-01-01

    Tritium (3H) activity of natural waters (precipitation, groundwater, surface waters) has recently become too low to be directly measured by low-level liquid scintillation (LSC) techniques. It is therefore necessary to perform electrolytical enrichment of tritium in such waters prior to LSC measurements. Electrolytical enrichment procedure has been implemented at the Rudjer Boskovic Institute (RBI) Tritium Laboratory in 2008, and since then 19 electrolyses have been completed. The mean enrichment factor E (a ratio between the final and initial 3H activities) after stabilisation of the system is E R BI = 22.5 @ 0.5, and the mean enrichment parameter (which describes the process of water mass reduction during electrolysis) is P R BI 0.949 @ 0.003. These values are comparable with those obtained at the Jo@ef Stefan Institute (JSI) Laboratory for liquid scintillation counting, at the electrolysis equipment of the same producer (AGH University of Science and Technology, Krakow, Poland) after 66 electrolyses carried out under identical conditions since 2007: E J SI = 18.9 @ 1.5, and P J SI = 0.896 @ 0.021. Both RBI and JSI laboratories have Ultra-low-level LSC Quantulus 1220 (Wallac, PerkinElmer) for measurement of 3H activity. A set of water samples having 3H activities in the range from 0 TU (''dead-water'' samples) to 18 000 TU (1 TU 0.118 Bq/L) were measured at both laboratories. Samples having 3H activity <200 TU were electrolytically enriched, while the others were measured directly in LSC. A very good agreement was obtained (correlation coefficient 0.991). Both laboratories participated in the IAEA TRIC2008 international intercomparison exercise. The analyses of reported 3H activity results in terms of z and u parameters showed that all results in both laboratories were acceptable. (author)

  5. Evaluation of the ionization quenching correction for several liquid scintillators; Evaluacion de la extincion por ionizacion para diversos liquidos centelleadores

    Energy Technology Data Exchange (ETDEWEB)

    Los Arcos, J M; Borras, C

    1990-07-01

    The most appropriate computational model for the ionization quenching function Q(E) is analyzed for electrons in liquid scintillators. A numerical evaluation of Q(E) from 0.1 keV to 3 MeV which the kB parameter varying between 0.005 and 0.010 cm/MeV is presented for seven scintillators; Toluene, Toluene-Alcohol, PCS, Toluene-CCl4, INSTAGEL, Dioxane-Naphtalene and HISAFE II. The numerical result are summarized as tables of Ieast squares fitting coefficient which make easy the computation of Q(E). (Author)

  6. Preparation of ferric acetylacetonate, bonzonate and caprate labelled with Fe-55 and tests of application to liquid scintillation measurements

    International Nuclear Information System (INIS)

    Los Arcos, J.M.; Rodriguez Barquero, L.; Grau Malonda, A.

    1990-01-01

    The methods of preparation of ferric acetylacetonate, benzoate and caprate labelled with 55 Fe are described. The quenching effect, the spectral baehaviour and the count rate stability are studied by liquid scintillation measurements in toluene, INSTAGEL and HISAFE II, for two different values of the sample concentration. The ferric acetylaceton-ate is stable for all the three scintillators but shows a strong quench, while the ferric benzoate and caprate are stable only for INSTAGEL and HISAFE II showing no significant quench at the concentrat-ions of interest in habitual measurements. (Author)

  7. Scintillation counting apparatus

    International Nuclear Information System (INIS)

    Noakes, J.E.

    1978-01-01

    Apparatus is described for the accurate measurement of radiation by means of scintillation counters and in particular for the liquid scintillation counting of both soft beta radiation and gamma radiation. Full constructional and operating details are given. (UK)

  8. Development of prototype liquid scintillator system for monitoring liquid radioactive waste

    International Nuclear Information System (INIS)

    Nam, Uk Won; Seon, Kwang Il; Kong, Kyoung Nam; Kim, Chang Kyu; Lee, Dong Myung; Lee, Sang Kook

    2003-01-01

    A prototype liquid scillatillator system for measurement of multiple beta-labeled mixtures was developed and its characteristic was investigated. The signal processing system consists of two photomultiplier tubes and the coincident count circuit. The characteristic of the system was analyzed using 4 beta-labeled samples ( 3 H, 14 C, 36 Cl and 90 Sr). Beta spectra from the samples were obtained without radiation shielding, and the detection limits for each nuclides were estimated based on the spectra. The estimated detection limits were compared to the legal regulation values. It is found that the liquid radioactive nuclides are detectable well below the legal regulation values

  9. Optics study of liquid scintillation counting systems; Estudio de la Optica en sistemas de medida por centelle liquido

    Energy Technology Data Exchange (ETDEWEB)

    Duran Ramiro, M. T.; Garcia-Torano, E.

    2005-07-01

    Optics is a key issue in the development of any liquid scintillation counting (LSC) system. Light emission in the scintillating solution, transmission through the vial and reflector design are some aspects that need to be considered in detail. This paper describes measurements and calculations carried out to optimise these factors for the design of a new family of LSC counters. Measurements of the light distribution emitted by a scintillation vial were done by autoradiographs of cylindrical vials made of various materials and results were compared to those obtained by direct measurements of the light distribution made by scanning the vial with a photomultiplier tube. Calculations were also carried out to study the light transmission in the vial and the optimal design of the reflector for a system with one photomultiplier tube. (Author)

  10. Absorption of scintillation light in a 100l liquid xenon γ-ray detector and expected detector performance

    International Nuclear Information System (INIS)

    Baldini, A.; Bemporad, C.; Cei, F.; Doke, T.; Grassi, M.; Grebenuk, A.A.; Grigoriev, D.N.; Haruyama, T.; Kasami, K.; Kikuchi, J.; Maki, A.; Mashimo, T.; Mihara, S.; Mitsuhashi, T.; Mori, T.; Nicolo, D.; Nishiguchi, H.; Ootani, W.; Ozone, K.; Papa, A.; Pazzi, R.; Ritt, S.; Sawada, R.; Sergiampietri, F.; Signorelli, G.; Suzuki, S.; Terasawa, K.; Yamashita, M.; Yamashita, S.; Yoshimura, T.; Yuri, Yu.

    2005-01-01

    An 800l liquid xenon scintillation γ-ray detector is being developed for the MEG experiment which will search for μ + ->e + γdecay at the Paul Scherrer Institut. Absorption of scintillation light of xenon by impurities might possibly limit the performance of such a detector. We used a 100l prototype with an active volume of 372x372x496mm 3 to study the scintillation light absorption. We have developed a method to evaluate the light absorption, separately from elastic scattering of light, by measuring cosmic rays and α sources. By using a suitable purification technique, an absorption length longer than 100cm has been achieved. The effects of the light absorption on the energy resolution are estimated by Monte Carlo simulation

  11. Automated high performance liquid chromatography and liquid scintillation counting determination of pesticide mixture octanol/water partition rates

    International Nuclear Information System (INIS)

    Moody, R.P.; Carroll, J.M.; Kresta, A.M.

    1987-01-01

    Two novel methods are reported for measuring octanol/water partition rates of pesticides. A liquid scintillation counting (LSC) method was developed for automated monitoring of 14 C-labeled pesticides partitioning in biphasic water/octanol cocktail systems with limited success. A high performance liquid chromatography (HPLC) method was developed for automated partition rate monitoring of several constituents in a pesticide mixture, simultaneously. The mean log Kow +/- SD determined from triplicate experimental runs were for: 2,4-D-DMA (2,4-dichlorophenoxyacetic acid dimethylamine), 0.65 +/- .17; Deet (N,N-diethyl-m-toluamide), 2.02 +/- .01; Guthion (O,O-dimethyl-S-(4-oxo-1,2,3-benzotriazin-3(4H)-ylmethyl) phosphorodithioate), 2.43 +/- .03; Methyl-Parathion (O,O-dimethyl-O-(p-nitrophenyl) phosphorothioate), 2.68 +/- .05; and Fenitrothion (O,O-dimethyl O-(4-nitro-m-tolyl) phosphorothioate), 3.16 +/- .03. A strong positive linear correlation (r = .9979) was obtained between log Kow and log k' (log Kow = 2.35 (log k') + 0.63). The advantages that this automated procedure has in comparison with the standard manual shake-flask procedure are discussed

  12. Gross alpha and gross beta determination in surface and groundwater water by liquid scintillation counting (LSC)

    International Nuclear Information System (INIS)

    Faria, Ligia S.; Moreira, Rubens M.

    2013-01-01

    The present study has used 40 samples of groundwater and surface water collected at four different sites along the period of one year in Brumadinho and Nova Lima, two municipalities in the State of Minas Gerais, Brazil, as part of a more extensive study aiming at determination of the natural radioactivity in the water used for domestic use. These two sites are inside an Environmental Protection Area is located in a region of very intensive iron ore exploration. In addition of mineral resources, the region has a geological characteristic that includes quartzitic conglomerates associated with uranium. Radioactivity levels were determined via liquid scintillation counting (LSC), a fast and high counting efficiency method that can be advantageously employed to determine gross alpha and gross beta activity in liquid samples. Previously to gross alpha and gross beta counting the samples were acidified with concentrated HNO 3 in the field. The technique involved a pre-concentration of the sample to obtain a low detection limit. Specific details of the employed methodology are commented. The results showed that concentrations of gross alpha natural activity and gross beta values ranged from less than the detection limit of the equipment (0.03 Bq.L -1 ) to 0.275 ± 0.05 Bq.L -1 for gross alpha. As regards gross beta, all samples were below the limit of detection. (author)

  13. Methyl salicylate as a medium for radioassay of 36Cl using a liquid scintillation spectrometer

    International Nuclear Information System (INIS)

    Wiebe, L.I.; Ediss, C.

    1976-01-01

    Methyl salicylate (MS), a high refractive index liquid with wave-shifting properties, has been used as a Cherenkov radiation generating medium for the radioassay of 36 Cl by liquid scintillation (LS) spectrometer. Comparative experiments, using both a standard toluene-based LS fluor and toluene alone, for the measurement of 36 Cl were undertaken. The methyl salicylate medium was found to perform at an intermediate counting efficiency, near that for the LS fluor. In the presence of moderate amounts of nitromethane, the MS was less susceptible to chemical quenching effects than either the fluor or toluene. Counting efficiencies for 36 Cl in MS, toluene and toluene fluor respectively were 82.4, 28.4 and 100.3 percent with a Picker Liquimat 220 LS spectrometer, and 91.6, 54.9 and 100.0 percent with a Searle Mark III LS spectrometer. The addition of nitromethane (11.3 percent of final volume) reduced these efficiencies to 50.5, 10.0 and 15.4 percent, and to 58.8, 12.4 and 19.0 percent, respectively. The data are discussed in relation to observed changes in the pulse height spectra. Chemical quench correction by ESCR and by SCR methods is reported

  14. Validated Models for Radiation Response and Signal Generation in Scintillators: Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Kerisit, Sebastien N.; Gao, Fei; Xie, YuLong; Campbell, Luke W.; Van Ginhoven, Renee M.; Wang, Zhiguo; Prange, Micah P.; Wu, Dangxin

    2014-12-01

    This Final Report presents work carried out at Pacific Northwest National Laboratory (PNNL) under the project entitled “Validated Models for Radiation Response and Signal Generation in Scintillators” (Project number: PL10-Scin-theor-PD2Jf) and led by Drs. Fei Gao and Sebastien N. Kerisit. This project was divided into four tasks: 1) Electronic response functions (ab initio data model) 2) Electron-hole yield, variance, and spatial distribution 3) Ab initio calculations of information carrier properties 4) Transport of electron-hole pairs and scintillation efficiency Detailed information on the results obtained in each of the four tasks is provided in this Final Report. Furthermore, published peer-reviewed articles based on the work carried under this project are included in Appendix. This work was supported by the National Nuclear Security Administration, Office of Nuclear Nonproliferation Research and Development (DNN R&D/NA-22), of the U.S. Department of Energy (DOE).

  15. Calibration of a liquid scintillation counter for alpha, beta and Cerenkov counting

    International Nuclear Information System (INIS)

    Scarpitta, S.C.; Fisenne, I.M.

    1996-07-01

    Calibration data are presented for 25 radionuclides that were individually measured in a Packard Tri-Carb 2250CA liquid scintillation (LS) counter by both conventional and Cerenkov detection techniques. The relationships and regression data between the quench indicating parameters and the LS counting efficiencies were determined using microliter amounts of tracer added to low 40 K borosilicate glass vials containing 15 mL of Insta-Gel XF scintillation cocktail. Using 40 K, the detection efficiencies were linear over a three order of magnitude range (10 - 10,000 mBq) in beta activity for both LS and Cerenkov counting. The Cerenkov counting efficiency (CCE) increased linearly (42% per MeV) from 0.30 to 2.0 MeV, whereas the LS efficiency was >90% for betas with energy in excess of 0.30 MeV. The CCE was 20 - 50% less than the LS counting efficiency for beta particles with maximum energies in excess of 1 MeV. Based on replicate background measurements, the lower limit of detection (LLD) for a 1-h count at the 95% confidence level, using water as a solvent, was 0.024 counts sec- -1 and 0.028 counts sec-1 for plastic and glass vials, respectively. The LLD for a 1-h-count ranged from 46 to 56 mBq (2.8 - 3.4 dpm) for both Cerenkov and conventional LS counting. This assumes: (1) a 100% counting efficiency, (2) a 50% yield of the nuclide of interest, (3) a 1-h measurement time using low background plastic vials, and (4) a 0-50 keV region of interest. The LLD is reduced an order of magnitude when the yield recovery exceeds 90% and a lower background region is used (i.e., 100 - 500 keV alpha region of interest). Examples and applications of both Cerenkov and LS counting techniques are given in the text and appendices

  16. Solute concentration dependence of the decay curves of the liquid scintillation

    International Nuclear Information System (INIS)

    Onishi, Masayoshi; Niki, Eiji.

    1976-01-01

    The decay curves of the liquid scintillation of 2,5-diphenyloxazole (PPO) in toluene by the irradiation of β ray from 14 C were measured. Solute concentration dependences of the decay times of the fast and slow components were studied. The decay time tau sub(f) of the fast component of the air saturated scintillator was the smallest at 1.8x10 -2 --4.5x10 -2 mol/l, and about (3.4--3.5)ns. When the concentration became less than 1.8x10 -2 mol/l, the peak of the decay curve became roundish and the pulse width became large. The increase of the necessary time for the energy transfer due to the difficulty of the nonradiative transfer from excited solvent molecules to the solute was the reason. When the concentration became less than about 2.26x10 -3 mol/l, tau sub(f) became larger and the energy transfer became radiative. The pulse width and tau sub(f) were very small because of oxygen quenching compared with oxygen free. At higher concentrations such as 1.6x10 -1 and 2.3x10 -1 mol/l, the effect of the PPO excimer was observed on the fast component, and tau sub(f) became larger apparently. This denied the presumption of the close relation between PPO molecular interaction and the slow component together with the fact that the decay time tau sub(s) of the slow component was independent of PPO concentration. (auth.)

  17. Comparison of the efficacy of biodegradable and non-biodegradable scintillation liquids on the counting of tritium- and [14C]-labeled compounds

    Directory of Open Access Journals (Sweden)

    Medeiros R.B.

    2003-01-01

    Full Text Available The widespread use of ³H and 14C in research has generated a large volume of waste mixed with scintillation liquid, requiring an effective control and appropriate storage of liquid radioactive waste. In the present study, we compared the efficacy of three commercially available scintillation liquids, Optiphase HiSafe 3, Ultima-Gold(TM AB (biodegradable and Insta-Gel-XF (non-biodegradable, in terms of [14C]-glucose and [³H]-thymidine counting efficiency. We also analyzed the effect of the relative amount of water (1.6 to 50%, radioisotope concentration (0.1 to 100 nCi/ml, pH (2 to 10 and color of the solutions (samples containing 0.1 to 1.0 mg/ml of Trypan blue on the counting efficiency in the presence of these scintillation liquids. There were few significant differences in the efficiency of 14C and ³H counting obtained with biodegradable or non-biodegradable scintillation liquids. However, there was an 83 and 94% reduction in the efficiency of 14C and ³H counting, respectively, in samples colored with 1 mg/ml Trypan blue, but not with 0.1 mg/ml, independent of the scintillation liquid used. Considering the low cost of biodegradable scintillation cocktails and their efficacy, these results show that traditional hazardous scintillation fluids may be replaced with the new safe biodegradable fluids without impairment of ³H and 14C counting efficiency. The use of biodegradable scintillation cocktails minimizes both human and environmental exposure to hazardous solvents. In addition, some biodegradable scintillation liquids can be 40% less expensive than the traditional hazardous cocktails.

  18. Digital liquid-scintillation counting and effective pulse-shape discrimination with artificial neural networks

    International Nuclear Information System (INIS)

    Langrock, Gert; Wiehl, Norbert; Kling, Hans-Otto; Mendel, Matthias; Naehler, Andrea; Tharun, Udo; Eberhardt, Klaus; Trautmann, Norbert; Kratz, Jens Volker

    2015-01-01

    A typical problem in low-level liquid scintillation (LS) counting is the identification of α particles in the presence of a high background of β and γ particles. Especially the occurrence of β-β and β-γ pile-ups may prevent the unambiguous identification of an α signal by commonly used analog electronics. In this case, pulse-shape discrimination (PSD) and pile-up rejection (PUR) units show an insufficient performance. This problem was also observed in own earlier experiments on the chemical behaviour of transactinide elements using the liquid-liquid extraction system SISAK in combination with LS counting. α-particle signals from the decay of the transactinides could not be unambiguously assigned. However, the availability of instruments for the digital recording of LS pulses changes the situation and provides possibilities for new approaches in the treatment of LS pulse shapes. In a SISAK experiment performed at PSI, Villigen, a fast transient recorder, a PC card with oscilloscope characteristics and a sampling rate of 1 giga samples s -1 (1 ns per point), was used for the first time to record LS signals. It turned out, that the recorded signals were predominantly α β-β and β-γ pile up, and fission events. This paper describes the subsequent development and use of artificial neural networks (ANN) based on the method of 'back-propagation of errors' to automatically distinguish between different pulse shapes. Such networks can 'learn' pulse shapes and classify hitherto unknown pulses correctly after a learning period. The results show that ANN in combination with fast digital recording of pulse shapes can be a powerful tool in LS spectrometry even at high background count rates.

  19. Digital liquid-scintillation counting and effective pulse-shape discrimination with artificial neural networks

    Energy Technology Data Exchange (ETDEWEB)

    Langrock, Gert; Wiehl, Norbert; Kling, Hans-Otto; Mendel, Matthias; Naehler, Andrea; Tharun, Udo; Eberhardt, Klaus; Trautmann, Norbert; Kratz, Jens Volker [Mainz Univ. (Germany). Inst. fuer Kernchemie; Omtvedt, Jon-Petter [Oslo Univ. (Norway). Dept. of Chemistry; Skarnemark, Gunnar [Chalmers Univ. of Technology, Goeteborg (Sweden)

    2015-05-01

    A typical problem in low-level liquid scintillation (LS) counting is the identification of α particles in the presence of a high background of β and γ particles. Especially the occurrence of β-β and β-γ pile-ups may prevent the unambiguous identification of an α signal by commonly used analog electronics. In this case, pulse-shape discrimination (PSD) and pile-up rejection (PUR) units show an insufficient performance. This problem was also observed in own earlier experiments on the chemical behaviour of transactinide elements using the liquid-liquid extraction system SISAK in combination with LS counting. α-particle signals from the decay of the transactinides could not be unambiguously assigned. However, the availability of instruments for the digital recording of LS pulses changes the situation and provides possibilities for new approaches in the treatment of LS pulse shapes. In a SISAK experiment performed at PSI, Villigen, a fast transient recorder, a PC card with oscilloscope characteristics and a sampling rate of 1 giga samples s{sup -1} (1 ns per point), was used for the first time to record LS signals. It turned out, that the recorded signals were predominantly α β-β and β-γ pile up, and fission events. This paper describes the subsequent development and use of artificial neural networks (ANN) based on the method of 'back-propagation of errors' to automatically distinguish between different pulse shapes. Such networks can 'learn' pulse shapes and classify hitherto unknown pulses correctly after a learning period. The results show that ANN in combination with fast digital recording of pulse shapes can be a powerful tool in LS spectrometry even at high background count rates.

  20. Optimization of the detector and associated electronics used for high-resolution liquid-scintillation alpha spectroscopy

    International Nuclear Information System (INIS)

    Thorngate, J.H.; Christian, D.J.

    1977-01-01

    The performance of various reflector geometries, light coupling liquids, photomultiplier tubes, preamplifiers and linear amplifiers were compared and the configuration found that optimized the combination of pulse-height resolution and pulse-shape discrimination. The best combination used a hemispherical reflector, filled with distilled water, coupled to an 8575 photomultiplier tube, the output of which was conditioned by a special integrating preamplifier and a double-delay-line linear amplifier. Careful choice of the scintillator, sample preparation procedures, and electronic apparatus can produce liquid-scintillation alpha spectroscopy with a pulse-height resolution of 300 keV, or less, and, by using pulse-shape discrimination, background levels as low as 0.01 counts/min. (author)

  1. A Procedure for the Rapid Determination of 226Ra and 228Ra in Drinking Water by Liquid Scintillation Counting

    International Nuclear Information System (INIS)

    2014-01-01

    Since 2004, the environment programme of the IAEA has included activities aimed at the development of a set of procedures for the determination of radionuclides in terrestrial environmental samples. Reliable, comparable and ‘fit for purpose’ results are essential requirements for any decision based on analytical measurements. For the analyst, tested and validated analytical procedures are extremely important tools for the production of such data. For maximum utility, such procedures should be comprehensive, clearly formulated and readily available to both the analyst and the customer. This publication describes a procedure for the rapid determination of 226 Ra and 228 Ra in drinking water. The determination of radium in drinking water is important for protecting human health, since the consumption of drinking water containing radium may lead to an accumulation in the body, contributing to the radiological dose. The method is based on the separation of 226 Ra and 228 Ra from interfering elements using PbSO 4 and Ba(Ra)SO 4 coprecipitation steps. The isotopes 226 Ra and 228 Ra are then determined by liquid scintillation counting. The procedure is expected to be of general use to a wide range of laboratories, including the laboratories of the Analytical Laboratories for the Measurement of Environmental Radioactivity (ALMERA) network, both in emergency situations and for routine environmental monitoring purposes. The method was established after an extensive review of papers from the scientific literature, and was tested and validated in terms of repeatability and trueness (relative bias) in accordance with International Organization for Standardization guidelines. Reproducibility tests were performed at expert laboratories. The calculation of massic activities, uncertainty budget, decision threshold and detection limit are also described

  2. Preparation of manganese salts of carboxylic acids labelled with ''54Mn and comparison with ''54 MnCl2 in liquid scintillation counting

    International Nuclear Information System (INIS)

    Rodriguez Barquero, L.; Arcos Merino, J. M. los; Grau Malonda, A.

    1992-01-01

    Procedures for liquid scintillation sample preparation of manganese dimethylbutirate, decanoate and palmitate, labelled with 54 Mn are described. their quenching effect, spectral evolution and counting stability along several weeks are analysed in liquid scintillation measurements with Toluene. HISafe II. PCS, instagel. Dioxane-naphtalene and Toluene-alcohol. For comparison, Inorganic 54 MnCl-2 samples are also studied, resulting in acceptable counting stability but showing greater quenching and signs of little spectral degradation against the organic samples. (Author)

  3. A Monte-Carlo code for neutron efficiency calculations for large volume Gd-loaded liquid scintillation detectors

    Energy Technology Data Exchange (ETDEWEB)

    Trzcinski, A.; Zwieglinski, B. [Soltan Inst. for Nuclear Studies, Warsaw (Poland); Lynen, U. [Gesellschaft fuer Schwerionenforschung mbH, Darmstadt (Germany); Pochodzalla, J. [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany)

    1998-10-01

    This paper reports on a Monte-Carlo program, MSX, developed to evaluate the performance of large-volume, Gd-loaded liquid scintillation detectors used in neutron multiplicity measurements. The results of simulations are presented for the detector intended to count neutrons emitted by the excited target residue in coincidence with the charged products of the projectile fragmentation following relativistic heavy-ion collisions. The latter products could be detected with the ALADIN magnetic spectrometer at GSI-Darmstadt. (orig.) 61 refs.

  4. Chemical and colour quenching in liquid scintillation counting; Estudio de la extincion quimica y por color en centelleo liquido

    Energy Technology Data Exchange (ETDEWEB)

    Scott, P E; Grau, A

    1987-07-01

    Chemical and colour quenching for H-3 and C-14 was studied. The method includes spectral analysis of colouring agents; methyl red, (4'-dimethylamine-azobenzene 2-carboxylic acid) dimethyl yellow (4'-dimethylamine-azobenzene) and malachite green (methane, bis .(4-dimethyl aminophenyl) - (phenyl)). External standard channels ratio was applied for the liquid scintillation counting of samples. The introduction of an isolated external standard seems to be a strong tool for the correction of chemical and colour quenching curves. (Author) 12 refs.

  5. Radiocarbon dating of samples for archaeologic and geologic interesting by liquid scintillation spectrometry with low background radiation

    International Nuclear Information System (INIS)

    Pessenda, L.C.R.; Camargo, P.B. de

    1991-01-01

    An analytical system for radiocarbon dating of environmental samples using low level liquid scintillation counting spectrometry was developed at the Center for Nuclear Energy in Agriculture, University of Sao Paulo. Physical and chemical pretreatment and benzene synthesis of samples, counting procedure, optimization of analytical parameters and laboratory intercomparison with radiocarbon laboratories of Center for Applied Isotope Studies, University of Georgia, USA and University of Waterloo, Canada, are described. (author)

  6. Rapid determination of gross alpha and beta activity in seafood utilizing microwave digestion and liquid scintillation counting

    International Nuclear Information System (INIS)

    Daniel Sas; Jiri Janda; Alena Tokarova

    2015-01-01

    This paper describes a method for rapid determination of gross alpha and beta activity in seafood using liquid scintillation counting and microwave digestion for fast sample decomposition. The general group of seafood was divided into two groups based on its structure, whether it has shell or not. The selected group of radionuclides was chosen with respect to military significance, radiotoxicity, and possibility of potential misuse. 90 Sr and 239 Pu were selected as model radionuclides. (author)

  7. Fast and sensitive determination of Sr-90 and SR-89 activity in milk by ion-chromatography and liquid scintillation

    International Nuclear Information System (INIS)

    Figueiredo, V.; Herrmann, A.

    1992-01-01

    A method for fast and exact determination of both strontium isotopes in milk and other foodstuffs, combination high performance ion chromatographic separation with by liquid scintillation counting, which enables the desired results to be obtained with very satisfactory precision and reproducibility within 24 hours, has been developed. The lowest detectable activity lies by 3 Bq/liter for Sr-90 and 1 Bq/liter for Sr-89 which is satisfactory for assessing a situation in a time crisis. (author)

  8. Alternating sample changer and an automatic sample changer for liquid scintillation counting of alpha-emitting materials

    International Nuclear Information System (INIS)

    Thorngate, J.H.

    1977-08-01

    Two sample changers are described that were designed for liquid scintillation counting of alpha-emitting samples prepared using solvent-extraction chemistry. One operates manually but changes samples without exposing the photomultiplier tube to light, allowing the high voltage to remain on for improved stability. The other is capable of automatically counting up to 39 samples. An electronic control for the automatic sample changer is also described

  9. Application of the Monte Carlo method to the study of the response of an organic liquid scintillator irradiated by photons

    International Nuclear Information System (INIS)

    Dupre, Corinne.

    1982-10-01

    The Monte Carlo method was applied to simulate the transport of a photon beam in an organic liquid scintillation detector. The interactions of secondary gamma rays and electrons with the detector and its peripheral materials components such as the pyrex glass container are included. The pulse height spectra and the detectors efficiency are compared with calculated and measured results. Calculations and programmation methods are presented in the same way as results concerning cobalt and cesium sources [fr

  10. Spectrum library concept and pulse shape analysis in liquid scintillation counting

    Energy Technology Data Exchange (ETDEWEB)

    Kaihola, L [Wallac Oy, Turku (Finland)

    1997-03-01

    Wallac introduced in 1990 a new absolute liquid scintillation counting (LSC) method, Digital Overlay Technique (DOT) to correct for quench. This method allows quantization of multilabel samples by referring to library spectra which are generated against chemical and color quench indices at the factory. The libraries can further be expanded to any beta emitter by user with a method called fine tuning, which can be carried out even with a single sample. Spectrum libraries are created over the whole spectrum range of the radionuclide and allow automatic identification of a single label beta emitting radionuclide, called Easy Count method. Another improvement in LSC is commercial introduction of Pulse Shape Analysis (PSA) in 1986 by Wallac. This method recognizes alpha particle decay by pulse shape and leads to excellent sensitivity in alpha counting because most of the background signal in LSC comprises of short or beta like pulses. PSA detects alpha events in the presence of high excess of beta activity over alphas, up to a ratio 100000 to 1. (orig.)

  11. Low Energy Neutrino Astronomy in the future large-volume liquid-scintillator detector LENA

    International Nuclear Information System (INIS)

    Wurm, Michael; Feilitzsch, F V; Goeger-Neff, M; Lewke, T; Undagoitia, T Marrodan; Oberauer, L; Potzel, W; Todor, S; Winter, J

    2008-01-01

    The recent successes in neutrino physics prove that liquid-scintillator detectors allow to combine high energy resolution, efficient means of background reduction, and a large detection volume. In the planned LENA (Low Energy Neutrino Astronomy) experiment, a target mass of 50 kt will enable the investigation of a variety of terrestrial and astrophysical neutrino sources. The high-statistics spectroscopy of geoneutrinos, solar neutrinos and supernova neutrinos will provide new insights in the heat production processes of Earth and Sun, and the workings of a gravitational collapse. The same measurements will as well investigate neutrino properties as oscillation parameters and mass hierarchy. A first spectroscopic measurement of the low flux of diffuse supernova neutrino background is within the sensitivity of the LENA detector. Finally, a life-time limit of several 1034 years can be set to the proton decay into proton and anti-neutrino, testing the predictions of SUSY theory. The present contribution includes a review of the scientific studies that were performed in the last years as well as a report on currently on-going R and D activities.

  12. Measurement of gross alpha and beta in air filter samples by using liquid scintillation counter

    International Nuclear Information System (INIS)

    Sudheendran, V.; Baburajan, A.; Gaikwad, R.H.; Ravi, P.M.; Tripathi, R.M.

    2015-01-01

    The determination of gross alpha and gross beta in particulate air filter samples was carried out by alpha, beta discrimination method using Liquid Scintillation Analyzer by setting the PSA value at 55 for 5 ml 0.1 HCl plus 15 ml of Ultima Gold AB cocktail by using 241 Am and 90 Sr/ 90 Y sources. The standardized method was compared with the gross alpha and gross beta activity determined by conventional method of direct counting with end window G.M. counter and ZnS (Ag). The minimum detectable activity of LSA method was found to be 9.3 mBq and 17.7 mBq for gross alpha and gross beta respectively for 6000 sec compared to the conventional method of 9.8 mBq and 189 mBq respectively at the same counting time. The result of analysis by both method indicate that the alpha, beta discrimination set up of LSA method is highly effective in the determination of low level alpha, beta activity in air filter samples. (author)

  13. Determination of the air/water partition coefficient of groundwater radon using liquid scintillation counter

    International Nuclear Information System (INIS)

    Lee, K.Y.; Yoon, Y.Y.; Ko, K.S.

    2010-01-01

    A method was studied for measuring air/water partition coefficient (K air/water ) of groundwater radon by a simple procedure using liquid scintillation counter (LSC). In contrast conventional techniques such as equilibrium partitioning in a closed system or air striping methods, the described method allow for a simple and uncomplicated determination of the coefficient. The (K air/water ) of radon in pure water has been well known quantitatively over a wide range of temperatures. In this work, groundwater samples having high radon concentration instead of distilled water have been used to determine the (K air/water ) of radon in the temperature range of 0-25. Aqueous phase in a closed system was used in this study instead of gaseous phase in conventional methods. Three kinds of groundwater taken from different geologic environments were used to investigate the effect of groundwater properties. With the aim to evaluate the reproducibility of the data an appropriate number of laboratory experiments have been carried out. The results show that tie (K air/water ) of radon in the groundwater is smaller than that in the pure water. However, the temperature effect on the coefficient is similar in the groundwater and the pure water. The method using aqueous phase in a closed system by LSC can be used to determine the (K air/water ) of radon in various groundwaters with a simple procedure. The results will be presented at the NAC-IV conference

  14. Using the transportable, computer-operated, liquid-scintillator fast-neutron spectrometer system

    International Nuclear Information System (INIS)

    Thorngate, J.H.

    1988-01-01

    When a detailed energy spectrum is needed for radiation-protection measurements from approximately 1 MeV up to several tens of MeV, organic-liquid scintillators make good neutron spectrometers. However, such a spectrometer requires a sophisticated electronics system and a computer to reduce the spectrum from the recorded data. Recently, we added a Nuclear Instrument Module (NIM) multichannel analyzer and a lap-top computer to the NIM electronics we have used for several years. The result is a transportable fast-neutron spectrometer system. The computer was programmed to guide the user through setting up the system, calibrating the spectrometer, measuring the spectrum, and reducing the data. Measurements can be made over three energy ranges, 0.6--2 MeV, 1.1--8 MeV, or 1.6--16 MeV, with the spectrum presented in 0.1-MeV increments. Results can be stored on a disk, presented in a table, and shown in graphical form. 5 refs., 51 figs

  15. Neutron and photon spectrometry with liquid scintillation detectors in mixed fields

    CERN Document Server

    Klein, H

    2002-01-01

    Liquid scintillation detectors of type NE213 or BC501A are well suited and routinely used for spectrometry in mixed n-gamma-fields. Neutron- and photon-induced pulse height spectra may be simultaneously recorded making use of the n/gamma-discrimination capability based on pulse shape analysis. The light output functions for the detected secondary charged particles, i.e. electrons, positrons, protons and other charged reaction products, and the pulse height resolution function must carefully be determined. This can be done experimentally, in part via an iterative procedure by comparison with calculations. The response functions can then be reliably calculated by Monte Carlo simulations. Photon response functions calculated with the PHRESP code, which was developed on the basis of the EGS4+PRESTA program package, are in very good agreement with calibrations up to 17 MeV, both in shape and absolute scale. Similarly, neutron response functions calculated with the NRESP7 code well describe the pulse height spectra...

  16. 210Pb and 210Po determination in environmental samples using liquid scintillation counting and alpha spectrometry

    International Nuclear Information System (INIS)

    Perez Sanchez, D.; Martin Sanchez, A.; Jurado Vargas, M.

    2003-01-01

    A simple radiochemical procedure has been developed to determine 210 Pb and 210 Po in environmental samples from the same matrix. Sediment samples are decomposed by leaching with mineral acids or by microwave digestion, while water samples are pre-concentrated. One part of the resulting solution, spiked with 209 Po, is used for 210 Po determination by spontaneous deposition onto nickel disks (a-spectrometry). The other part is assayed for 210 Pb, separating the Pb either by anion-exchange (sediment samples), or by solvent extraction (water samples). The 210 Pb source is finally prepared by precipitation as oxalate and the chemical recovery determined by gravimetry. The 210 Pb activity concentration is determined by liquid scintillation. A standard sediment sample supplied by IAEA and spiked water samples were analysed to check the procedure. The 210 Pb and 210 Po measurements agreed well with the certifications, deviations being less than 10%. The mean recoveries for Pb and Po were (70±12)% and (77±8)% for sediments, and (70±10)% and (81±7)% for waters, respectively. (author)

  17. Recent advances in low-level β-counting by liquid scintillation instrumentation

    International Nuclear Information System (INIS)

    Verzilov, Yu.; Maekawa, Fujio; Oyama, Yukio; Maekawa, Hiroshi

    1995-01-01

    This work attempts to solve problems for measurement 3 H and 32 P activity. A measurement of tritium activity in materials is desired for neutron experiments such as a fusion reactor blanket experiment and a neutron flux monitor with 6 Li(n,α) 3 H reaction. In such studies, lithium-containing pellets are usually irradiated by neutrons and the tritium produced in them is measured with a liquid scintillation counter. Tritium technique for Li 2 CO 3 is the subject of interest in the present study because this compound is well soluble and easy to use it. The 32 P is important nuclide in the in-system neutron spectrometry due to the following reactions: 31 P(n,γ) 32 P, 32 S(n,p) 32 P and 35 Cl(n,α) 32 P. For the reasons of similarity with Li 2 CO 3 , NH 4 PH 2 O 2 , CH 3 SO 2 CH 3 and NH 4 Cl were selected for measurement of 32 P activity. (J.P.N.)

  18. Low Energy Neutrino Astronomy in the future large-volume liquid-scintillator detector LENA

    Energy Technology Data Exchange (ETDEWEB)

    Wurm, Michael; Feilitzsch, F V; Goeger-Neff, M; Lewke, T; Undagoitia, T Marrodan; Oberauer, L; Potzel, W; Todor, S; Winter, J [E15 Chair for Astroparticle Physics, Technische Universitat Miinchen, Physik Department, James-Franck-Str., D-85748 Garching (Germany)

    2008-11-01

    The recent successes in neutrino physics prove that liquid-scintillator detectors allow to combine high energy resolution, efficient means of background reduction, and a large detection volume. In the planned LENA (Low Energy Neutrino Astronomy) experiment, a target mass of 50 kt will enable the investigation of a variety of terrestrial and astrophysical neutrino sources. The high-statistics spectroscopy of geoneutrinos, solar neutrinos and supernova neutrinos will provide new insights in the heat production processes of Earth and Sun, and the workings of a gravitational collapse. The same measurements will as well investigate neutrino properties as oscillation parameters and mass hierarchy. A first spectroscopic measurement of the low flux of diffuse supernova neutrino background is within the sensitivity of the LENA detector. Finally, a life-time limit of several 1034 years can be set to the proton decay into proton and anti-neutrino, testing the predictions of SUSY theory. The present contribution includes a review of the scientific studies that were performed in the last years as well as a report on currently on-going R and D activities.

  19. Direct measurement of radioactive carbon in Vietnamese vodkas by Liquid Scintillation Counter

    International Nuclear Information System (INIS)

    Hattori, Takamitsu

    2014-01-01

    From the view point of applying to laboratory exercise of radioactivity measurement by a Liquid Scintillation Counter (LSC), Vietnamese vodkas have specific features as measurement samples, for example, they are colorless, have high ethanol content, and only very few organic materials are included. Investigation was made to make sure that the Vietnamese vodkas are appropriate or not as a measurement sample for the LSC exercise. Direct measurements of 14 C without any chemical pre-treatment were made on both radioactive concentrations and specific activities of three kinds of Vietnamese vodka and also pure ethanol reagent. The LSC measurements reveal that estimated 14 C concentration is proportional to ethanol content in samples and that specific activity of 14 C shows good agreement among the Vietnamese vodkas and pure ethanol, as well as the reference value of 0.25 Bq/g of Carbon. Thus the conclusion is derived that the Vietnamese vodkas can be applied with high accuracy to the LSC exercise as measurement samples. (author)

  20. A high-resolution tracking hodoscope based on capillary layers filled with liquid scintillator

    CERN Document Server

    Bay, A; Bruski, N; Buontempo, S; Currat, C; D'Ambrosio, N; Ekimov, A V; Ereditato, A; Fabre, Jean-Paul; Fanti, V; Frekers, D; Frenkel, A; Golovkin, S V; Govorun, V N; Harrison, K; Koppenburg, P; Kozarenko, E N; Kreslo, I E; Liberti, B; Martellotti, G; Medvedkov, A M; Mondardini, M R; Penso, G; Siegmund, W P; Vasilchenko, V G; Vilain, P; Wilquet, G; Winter, Klaus; Wörtche, H J

    2001-01-01

    Results are given on tests of a high-resolution tracking hodoscope based on layers of \\hbox{26-$\\mu$m-bore} glass capillaries filled with organic liquid scintillator (1-methylnaphthalene doped with R39). The detector prototype consisted of three 2-mm-thick parallel layers, with surface areas of $2.1 \\times 21$~cm$^2$. The layers had a centre-to-centre spacing of 6~mm, and were read by an optoelectronic chain comprising two electrostatically focused image intensifiers and an Electron-Bombarded Charge-Coupled Device (EBCCD). Tracks of cosmic-ray particles were recorded and analysed. The observed hit density was 6.6~hits/mm for particles crossing the layers perpendicularly, at a distance of 1~cm from the capillaries' readout end, and 4.2~hits/mm for particles at a distance of 20~cm. A track segment reconstructed in a single layer had an rms residual of $\\sim$~20~$\\mu$m, and allowed determination of the track position in a neighbouring layer with a precision of $\\sim$~170~$\\mu$m. This latter value corresponded to...

  1. The measurement of 222Rn in drinking water by low-level liquid scintillation counting

    International Nuclear Information System (INIS)

    Barnett, J.M.; McKlveen, J.W.

    1992-01-01

    Radon-222 (Rn) has universally been found in well water. Non-stagnant ground water is collected at the well head while the well is pumping. The water is adjusted to a slow, non-aerated, steady flow through a clear tube, and a 500 ml glass bottle is filled. The sample is tightly capped after a high meniscus has developed. In the laboratory, standard 22 ml glass vials are filled with 10 ml of a toluene based mineral oil LS cocktail. Then, two 5 ml sample aliquots are pipetted into the vial. Vials are capped tightly, shaken vigorously, and placed in the liquid scintillation (LS) counter. Secular equilibrium is established in approximately 4 hours, after which samples are counted for 100 minutes each. The counting efficiency for Rn and progeny ranges between 315 to 345 percent depending on the chosen spectral window. The average background is about 6 cpm. A total of 28 wells were tested for Rn in the Carefree-Cave Creek, Arizone, USA area. The area's geometric average Rn concentration was found to be 46.5 Bq*1 -1 . The associated estimated lung dose is 0.51 mSv*y -1 . (author) 8 refs.; 1 fig.; 1 tab

  2. High efficiency scintillation detectors

    International Nuclear Information System (INIS)

    Noakes, J.E.

    1976-01-01

    A scintillation counter consisting of a scintillation detector, usually a crystal scintillator optically coupled to a photomultiplier tube which converts photons to electrical pulses is described. The photomultiplier pulses are measured to provide information on impinging radiation. In inorganic crystal scintillation detectors to achieve maximum density, optical transparency and uniform activation, it has been necessary heretofore to prepare the scintillator as a single crystal. Crystal pieces fail to give a single composite response. Means are provided herein for obtaining such a response with crystal pieces, such means comprising the combination of crystal pieces and liquid or solid organic scintillator matrices having a cyclic molecular structure favorable to fluorescence. 8 claims, 6 drawing figures

  3. Detection of high energy gamma radiations with liquid rare gases as scintillators; Detection des rayonnements Gamma de grande energie avec les gaz rares liquides comme scintillateurs

    Energy Technology Data Exchange (ETDEWEB)

    Ho, Phan Xuan

    1965-11-25

    This research thesis reports the study of a sensor based on a liquid scintillator for the detection of high energy (10 to 30 MeV) gamma radiations. The scintillator is a liquefied argon or xenon rare gas. The author first studies the process of energy transfer from the particle to the sensing medium. He addresses the different involved elements and phenomena: electromagnetic radiations (Compton Effect, photoelectric effect, pair production, and total gamma absorption), charged particles (braking radiation, collisions) and application to gamma spectrometry. He describes and discusses the scintillation mechanisms (scintillation of organic and inorganic materials), the general characteristics of scintillators (impurities, converters), and then reports the practical realisation of the sensor. Results are presented and discussed [French] Dans ce travail, nous nous proposons d'etudier une technique. Il s'agit d'un detecteur a scintillateur liquide pour la detection des rayonnements gamma energiques (10 a 30 MeV). Le scintillateur utilise est un gaz rare liquefie argon ou xenon. Nous examinerons d'abord les processus de transfert de l'energie de la particule au milieu detecteur puis les mecanismes de scintillation en general pour pouvoir exploiter au mieux les phenomenes favorables. Nous presenterons ensuite la realisation pratique du detecteur. Ses qualites (et defauts) trouveront leur place dans la fin de ce memoire. Bien qu'a l'heure actuelle, par la methode de Kyropoulos, on puisse faire pousser des gros cristaux d'iodure de sodium, l'utilisation des 'gaz rares' liquefies comme scintillateurs est, grace a la brievete de la scintillation, tres utile lorsqu'on recherche un fort taux de comptage (jusqu'a 10 impulsions par seconde) ou lorsqu'on veut resoudre certains problemes de coincidence. Les cristaux NaI(Tl) de grandes dimensions sont d'un montage facile mais leur manipulation requiert beaucoup de precautions du fait qu'ils supportent tres mal les chocs thermiques

  4. Discriminator setting and cocktail preparation for analysis of alpha and beta emitters in aqueous solution using liquid scintillation counter

    International Nuclear Information System (INIS)

    Zaini Hamzah; Masitah Alias; Zaharudin Ahmad

    2011-01-01

    Liquid scintillation counting (LSC) is not only being used to measure pure beta emitters, but it can be used to measure both alpha and beta emitters simultaneously. Measurement of alpha and beta emitters in aqueous solution is done using a single sample. For the sample preparation, colorless detergent or emulsifier was used to incorporate the water into an organic based scintillator to produce a clear homogeneous solution, since this is the best form to give the highest count rate and detection efficiency. The instrument also need some attention, where after calibration, the LSC was set for the discriminator level which is suitable for measurement of both alpha and beta radiations. In this study, the focus is on the development of the best scintillation cocktail and establishes the best discriminator setting. From this study the best proportion of scintillation cocktail is 2:4:4 for water, toluene, and Triton-N101 (emulsifier) respectively and the best discriminator setting for alpha and beta counting are 120. (author)

  5. Calibration of radionuclides with decay trough beta emission or electron capture by liquid scintillation technique

    International Nuclear Information System (INIS)

    Loureiro, Jamir dos Santos

    2000-02-01

    In this work is reported a methodology a methodology for pure beta and electron capture radionuclides standardization, suing liquid scintillation technique. In this sense the CIEMAT/NIST method, recently utilized by international laboratories, was implemented and the lack in the Laboratorio Nacional das Radiacoes Ionizantes - LNMRI, of the Comissao Nacional de Energia Nuclear - CNEN, for adequate methodology to standardize this kind if radionuclides was filled, fact that was not present with alpha and gamma radionuclides. The implementation procedure evaluation was provided by concentration activity determination of the following radionuclides: 14 C and 90 Sr, pure beta emitters; 55 Fe, electron capture decay; 204 Tl, electron capture and beta decay and 60 Co, beta-gamma emitter. In this way, a careful analysis of the implementation procedure with these radionuclides types, ranging on a broad energy spectral, was possible. To check the calibration results, intercomparisons among our measurements of these radionuclides and the reference values of the CIEMAT/Spain laboratory were provided. To check the calibration results, intercomparisons among our measurements of these radionuclides and the reference values of the CIEMAT/Spain laboratory were provided. Besides this intercomparisons, one was provided with a 204 Tl solution, utilized in the international comparison recently promoted by BIPM, and another one with a 60 C solution calibrated in LNMRI/CNEN previously by a relative calibration system, with a well type pressurized ionization chamber, and an absolute beta-gamma coincidence system, with a pill-box type proportional counter 4 π geometry, coupled with a scintillator system with a sodium iodide cristal of 4x4 inches. The comparisons among LNMRI/CNEN results and the reference values, showed a small deviation of 1,32% for 14 C, 0,40% for 60 Co, 1,12% for 55 Fe, 0,10% for 90 Sr and 0,73% for 204 Tl. For the BIPM solution the deviation was 0,46% and for 60 Co

  6. Neutron-Gamma Pulse Shape Discrimination With Ne-213 Liquid Scintillator By Using Digital Signal Processing Combined With Similarity Method

    International Nuclear Information System (INIS)

    Mardiyanto

    2008-01-01

    Neutron-Gamma Pulse Shape Discrimination with a NE-213 Liquid Scintillator by Using Digital Signal Processing Combined with Similarity Method. Measurement of mixed neutron-gamma radiation is difficult because a nuclear detector is usually sensitive to both radiations. A new attempt of neutron-gamma pulse shape discrimination for a NE-213 liquid scintillator is presented by using digital signal processing combined with an off-line similarity method. The output pulse shapes are digitized with a high speed digital oscilloscope. The n-γ discrimination is done by calculating the index of each pulse shape, which is determined by the similarity method, and then fusing it with its corresponding pulse height. Preliminary results demonstrate good separation of neutron and gamma-ray signals from a NE-213 scintillator with a simple digital system. The results were better than those with a conventional rise time method. Figure of Merit is used to determine the quality of discrimination. The figure of merit of the discrimination using digital signal processing combined with off-line similarity method are 1.9; 1.7; 1.1; 1.1; and 0.8; on the other hand by using conventional method the rise time are 0.9; 0.9; 0.9; 0.7; and 0.4 for the equivalent electron energy of 800; 278; 139; 69; and 30 keV. (author)

  7. Fast technetium Eigen-colloid determination: preparative CPC combined with suspension liquid scintillation

    International Nuclear Information System (INIS)

    Breynaert, E.; Maes, A.

    2005-01-01

    Full text of publication follows: Both medical and environmental studies concerned with the solubility and the complexation chemistry of technetium have encountered colloidal Tc(IV)-forms. Although the existence of the Tc colloids has been proven by various techniques [1-6], their determination still remains an issue. Recently a Column Precipitation Chromatography (CPC) technique was developed which enabled the quantitative determination of technetium Eigen-colloids. Based on this technique, a solid phase extraction (SPE)-like methodology was developed that can be used in combination with suspension liquid scintillation to provide a fast analysis of the Eigen-colloid content of a sample. The CPC technique is a thorough analysis methodology for the quantitative determination of the Eigen-colloid content of a sample containing reduced technetium species. This technique requires a relative long elution scheme and fractionation of the eluate. The fractionation also implies a relatively long counting time to determine the Eigen-colloid activity of a sample. Currently an SPE-like analysis methodology was developed which combines a good estimate of the Eigen-colloid content with fast analysis times. To construct a methodology providing both features a specialized extraction apparatus was constructed and a quantitative suspension liquid scintillation technique was developed. This combination enables the Eigen-colloid determination within a short experimental time (15 min) and a limited counting time (60 min). The authors acknowledge a grant from KULeuven University and financial support from the KULeuven Geconcerteerde Onderzoeksacties (GOA2000/007). We also kindly acknowledge NIRAS/ONDRAF for financial support from Contract CCHO 20004004862 [1] Grossmann, B. and R. Muenze, Relationship between complex formation by 99 Tc(IV) and the chemical structure of aliphatic carboxylic acid ligands. The International Journal of Applied Radiation and Isotopes, 1982. 33(3): p. 189

  8. Process for the automatic compensation of spectral displacement based on quenching processes in a liquid scintillation counter

    International Nuclear Information System (INIS)

    Nather, R.E.

    1978-01-01

    In measurements in a liquid scintillation counter, the tritium or C 14 isotope to be examined is situated in a scintillator solution. It is excited according to the energy of the β particle to emit light. An electrical signal is proportional to the light signal, and from the former, selective counting in the β spectrum can be undertaken in an impulse height analyser. The influence of the quenching effects by colour quenching or chemical quenching would reduce the gain of the counter. To compensate for the displacement of the spectrum, the required adjustment of a system parameter is carried out by calibration with a sample of low quenching effect. The calibration process is directly set for the energy end-point of the spectrum. Well known processes can be used to determine the quenching effect of the quenching represented by the sample. For example, the system parameters can be the discriminator level of the counter window. (DG) 891 HP [de

  9. Counting efficiencies by liquid scintillation counting. Single isomeric transitions; Eficiencia de recuento por centelleo liquido. Transiciones isomericas simples

    Energy Technology Data Exchange (ETDEWEB)

    Grau Carles, A.; Grau Malonda, A.

    1995-07-01

    In this work we present liquid scintillation counting efficiency tables for several radionuclides with single isomeric transitions, in which electron conversion and gamma emission processes are competitive. We study the radionuclides: 58mCo, 77mSe, 79mBr, 87mSr, S9mY, 93mNb, 103mRh, 107mAg, 109mAg, 113mIn, 131mXe, I33mXe, 135raBa, 137mBa, 167raEr, for two different scintillators, Ultima-Gold and Insta-Gel. We consider volumes of 10 and 15 mL for Ultima Gold, and 15 mL for Insta-Gel. (Author) 18 refs.

  10. Rapid radiometric detection of microbial contamination using 14C-glucose and standard liquid scintillation counting system

    International Nuclear Information System (INIS)

    Joshi, S.H.; Kamble, S.B.; Pilkhwal, N.S.; Ramamoorthy, N.

    1998-01-01

    A simple and rapid method for detection of microbial contamination based on quantitation of 14 CO 2 released during metabolism of 14 C-Glucose by microorganisms is reported. Liquid scintillation counting system (LSCS) with a modified sample preparation method was utilised. The scintillator was impregnated on Whatman-1 paper on which 14 CO 2 evolved during metabolism could be absorbed. The important parameters of counting such as efficiency, position sensitivity and geometry as well as effect of NaOH quantity and of microbial load on detection period were studied. The efficiency of radioactivity assay was 18±2.8 %. Contamination of the order of 5-10 organism/ml of product could be detected in about 24 hours. (author)

  11. A comparative study of 19-iodocholesterol-''125I 3-acetate and Na''125I in liquid scintillation measurements

    International Nuclear Information System (INIS)

    Rodriguez Barquero, L.; Grau Malonda, A.; Los Arcos Merino, J.M.; Grau Carles, A.

    1994-01-01

    A comparative study of performance of 19-iodocholesterol-''125I 3-acetate and sodium iodine samples labelled with ''125 I is presented for liquid scintillation counting measurements. Quench effect, count rate stability and spectral evolution of samples have been followed for several weeks in Toluene, Hisafe II, Instagel, Dioxane-naphthalene and Toluene-alcohol scintillators. Organic samples have negligible quench effect in the interval of I''-concentration of 0-90 ug and inorganic samples only show a very small variation, lower than 12%, for Dioxane-naphthalene, in the same range of concentration. Satisfactory stability is obtained in general for both, organic and inorganic samples, but small counting losses, 0.03% for 19-iodocholesterol-''125I 3-acetate samples in Toluene-alcohol and 0.04% for Na''125I samples in Dioxane-naphthalene and Toluene-alcohol, have been reported. (Author) 8 refs

  12. A comparative study of 19-iodo cholesterol-125I 3-acetate and Na 125I in liquid scintillation measurements

    International Nuclear Information System (INIS)

    Rodriguez Barquero, L.; Grau Malonda, A.; Los Arcos Merino, J. M.; Grau Carles, A.

    1994-01-01

    A comparative study of performance of 19-iodo cholesterol 1 25I 3-acetate and sodium iodide samples labeled with 125I is presented for liquid scintillation counting measurements. Quench effect, count rate stability and spectral evolution of samples have been followed for several weeks in Toluene, Hisafe II, Instagel, Dioxane-naphthalene and Toluene-alcohol scintillators. Organic samples have negligible quench effect in the interval of I concentration of 0-90 μg and inorganic samples only show a very small variation, lower than 12%, for Dioxane-naphthalene, in the same range of concentration. Satisfactory stability is obtained in general for both, organic and inorganic samples, but small counting losses, 0.03% for 19-iodocholesterol 1 I 3-acetate samples in Tolue ne-alcohol and 0 .04% for Na 125I samples in Dioxane-naphthalene and Toluene-alcohol, have been reported. (Author) 8 refs

  13. 210Pb and 210Po determination in environmental samples using liquid scintillation counting and alpha spectrometry

    International Nuclear Information System (INIS)

    Sanchez, D.P.; Sanchez, A.M.; Vargas, M.J.

    2002-01-01

    A simple radiochemical procedure has been developed to determine 210 Pb and 210 Po in environmental samples. After adding 209 Po tracer and Pb carrier, an aliquot of the sample is decomposed by microwave digestion or by evaporation with mineral acids (depending on the expected activity of the sample). Part of the leaching solution must be used for 210 Po determination, preparing a polonium source by spontaneous deposition onto a nickel disk. The quantitative recoveries are determined using a standard 209 Po tracer, and the activity concentration is determined by isotopic dilution alpha spectrometry. The remaining part of the leaching solution is used for 210 Pb determination by means of two alternative methods: lead can be retained from 1.5 M HCl by the DOWEX 1 X 8, Cl - form resin in a chromatographic column, and stripped with deionised water, or it can be separated by solvent extraction as a lead bromide complex with the organic compound ALIQUAT-336 in toluene (this second method is used preferably in water samples). The Pb source for measurement is prepared by precipitation as oxalate and the chemical recovery determined by gravimetry. The activity concentration of 210 Pb is calculated from the spectra measured with a liquid scintillation spectrometer. Several certified material samples supplied by IAEA were analysed to check the procedure. The measured values for 210 Pb and 210 Po were in good agreement with the certified values presenting deviations lower than 5%. Several environmental samples (river and well waters and also sediments) from zones impacted by Uranium mine exploitation were analysed using the described procedure. The mean yields of Pb and Po were (70 ± 10)% and (81 ± 7)% for waters and (70 ± 12)% and (77 ± 8)% for sediments. (author)

  14. The measurement of Rn-222 in drinking water by low-level liquid scintillation counting

    International Nuclear Information System (INIS)

    Barnett, J.M.; McKlveen, J.W.

    1991-01-01

    Radon-222 has consistently been found in well water. The research objectives are to establish a method to collect well water and to measure the Rn in ground water using liquid scintillation (LS) counting. Water is collected at the well head while the well is pumping. The water is adjusted to a slow, non-aerated, steady flow through a clear tube, and a 437 mL (16 oz) glass bottle is filled. The sample is tightly capped after a high meniscus has developed. In the laboratory, standard 22 mL LS glass vials are filled with 10 mL of a toluene based mineral oil LS cocktail. Then, two 5 mL sample aliquots are pipetted into the vial. Vials are capped tightly, shaken vigorously, and placed in the LS counter. Secular equilibrium is established in approximately 3.5 hours, after which samples are counted for 100 minutes each. Quality assurance and control is performed weekly on the LS counter's electronics, spectral window, counting efficiency, and background. The counting efficiency ranges between 315-345 percent depending on the chosen spectral window. The average background is about 6 cpm. A total of 28 wells were tested for Rn in the Carefree-Cave Creek, Arizona, USA area, and 12 wells were selected, each over 50 Bq/L (1,350 pCi/L), for an extended 6 month period. The area's average Rn concentration was found to be 46.5 Bq/L (1,255 pCi/L); it is a geometric mean. The associated estimated lung dose is 1.13 mSv/a

  15. Correct liquid scintillation counting of steroids and glycosides in RIA samples: a comparison of xylene-based, dioxane-based and colloidal counting systems. Chapter 14

    International Nuclear Information System (INIS)

    Spolders, H.

    1977-01-01

    In RIA, the following parameters are important for accurate liquid scintillation counting. (1) Absence of chemiluminescence. (2) Stability of count rate. (3) Dissolving properties for the sample. For samples with varying colours, a quench correction must be applied. For any type of accurate quench correction, a homogeneous sample is necessary. This can be obtained if proteins and the buffer can be dissolved completely in the scintillator solution. In this paper, these criteria are compared in xylene-based, dioxane-based and colloidal scintillation solutions for either bound or free antigens of different polarity. The labelling radioisotope used was 3 H. Using colloidal scintillators with plasma and buffer samples, phasing or sedimentation of salt or proteins sometimes occurs. The influence of sedimentation or phasing on count rate stability and correct quench correction is illustrated by varying the ratio between the scintillator solution and a RIA sample containing a semi-polar steroid aldosterone. (author)

  16. Development of a liquid scintillation method for in vitro determination of 226Ra and 228 Ra in bioassay samples

    International Nuclear Information System (INIS)

    Fernandes, Paulo Cesar P.; Sousa, Wanderson O.; Juliao, Ligia M.Q.C.; Dantas, Bernardo M.

    2011-01-01

    Radium isotopes are dispersed in the environment according to their physicochemical characteristics. The intake of 226 Ra and 228 Ra in humans can occur by inhalation and ingestion and the risk of internal exposure are related to their long half-lives, characteristics of the emission and biokinetics of the isotopes in the human body. The goal of this work is to develop a methodology for the analysis of 226 Ra and 228 Ra in excreta samples (urine and feces), using liquid scintillation technique. Excreta samples were provided by non-exposed humans for the purpose of standardizing the methodology and the establishment of a background level of radium excretion. Radium isotopes were concentrated and separated from the constituents of the sample by co-precipitation with barium sulphate. The precipitate of Ba(Ra)SO 4 was filtrated and weighted for the determination of the chemical yield. The filter containing the precipitate was transferred to a scintillation vial. In the scintillation vial, 8 mL of water, 8 mL of Instagel XF and 4 mL of UltimaGold were added, forming a gel suspension, after stirring the solution. The 226 Ra and 228 Ra activities were determined 21 days after the precipitation of samples. The samples were counted in a liquid scintillation spectrometer. The technique presented adequate sensitivity and reproducibility for the analysis of urine and feces. The activities of 226 Ra and 228 Ra in excreta samples provide useful information for the identification of the main route of intake and for the assessment of the internal exposure of occupationally exposed workers and inhabitants of high background areas. (author)

  17. Validation of the α-μ Model of the Power Spectral Density of GPS Ionospheric Amplitude Scintillation

    Directory of Open Access Journals (Sweden)

    Kelias Oliveira

    2014-01-01

    Full Text Available The α-μ model has become widely used in statistical analyses of radio channels, due to the flexibility provided by its two degrees of freedom. Among several applications, it has been used in the characterization of low-latitude amplitude scintillation, which frequently occurs during the nighttime of particular seasons of high solar flux years, affecting radio signals that propagate through the ionosphere. Depending on temporal and spatial distributions, ionospheric scintillation may cause availability and precision problems to users of global navigation satellite systems. The present work initially stresses the importance of the flexibility provided by α-μ model in comparison with the limitations of a single-parameter distribution for the representation of first-order statistics of amplitude scintillation. Next, it focuses on the statistical evaluation of the power spectral density of ionospheric amplitude scintillation. The formulation based on the α-μ model is developed and validated using experimental data obtained in São José dos Campos (23.1°S; 45.8°W; dip latitude 17.3°S, Brazil, located near the southern crest of the ionospheric equatorial ionization anomaly. These data were collected between December 2001 and January 2002, a period of high solar flux conditions. The results show that the proposed model fits power spectral densities estimated from field data quite well.

  18. The determination of Pu-241 by liquid scintillation counting in gaseous effluents of an incineration facility, FERAB, and the Karlsruhe Nuclear Reprocessing Plant, WAK

    International Nuclear Information System (INIS)

    Godoy, J.M.; Schuettelkopf, H.

    1983-03-01

    Although the concentration of Pu-241 in nuclear fuel to be reprocessed is high, there are only few results published about the emission of Pu-241 with gaseous and liquid effluents. Nearly no information is available, too, about the environmental contamination of nuclear installations by Pu-241. Therefore a procedure was developed to measure Pu-241 by liquid scintillation counting. Sample preparation was performed by electroplating of plutonium on stainless steel planchets. To correct the selfabsorption the linear dependence of counting efficiency in the liquid scintillation counter and the resolution in the α-spectrometer was used. (orig./HP) [de

  19. Preparation of 45Ca(HDEHP)n and (CaH1502)2 samples for liquid scintillation counting, compared to 45caCl2 results

    International Nuclear Information System (INIS)

    Rodriguez, L.; Arcos, J. M. los; Grau Malonda, A.

    1994-01-01

    A procedure for preparation of liquid scintillation counting organic samples of the Di-2-ethylhexyl phosphate calcium complex and the 2-ethylhexanoate calcium salt, labelled with 45Ca, is described. The chemical quench, the counting stability and spectral evolution of both compounds is studied in six scintillators,Toluene-alcohol, Dioxane-naphtalene, Hi safe II, Ultimate-Gold and Instagel, and compared to results obtained from a commercial solution of 4 5CaCl2. (Author) 7 refs

  20. Internal Dosimetry Of I-131 For Radiation Workers Based On Analysis Of The Human Urine And Liquid Scintillation Counting

    International Nuclear Information System (INIS)

    Nguyen Van Hung; Pham Hung Thai; Le Van Ngoc

    2011-01-01

    Internal dosimetry of I-131 for radiation workers based on analysis of the human urine, measuring radioactivity by the liquid scintillation system, and dose calculation by the specialized code has been firstly studied at the Nuclear Research Institute. Urine samples from the subjects internally contaminated with I-131 through respiratory ways were collected, chemically processed, measured beta radioactivities of I-131 by the liquid scintillation system of ALOKA-LSC-6100, and then thyroid doses and effective ones for whole-body were calculated by using the specialized code of LUDEP 2.0. Based on chemically separation procedure for I-131 in urine samples and the low background HPGe gamma spectrometer of Canberra for measuring radioactivity, efficiency for chemical separation was determined to be (86.1 ± 5.0)%. The experimental results for 9 subjects with urine samples to be collected during 4 operating courses of Dalat nuclear reactor with production of I-131 (from June to September, 2010) were shown that thyroid doses and effective ones for whole-body for each course of I-131 production were in ranges of from 0.11 to 13.00 mSv and from 0.01 to 0.71 mSv, respectively. Therefore, totally average doses per year for thyroid and whole-body were less than the correlative levels of permissible doses. Besides, the liquid scintillation method was also compared experimentally with the gamma spectrometry (measuring directly urine samples by the gamma spectrometer to be carried out at the Institute before) was shown that errors on dosimetric results between them were less than 12%. This was proved the dosimetry has had a confidence, and it could be applied for internal dosimetry for radiation workers contacting with unsealed sources of I-131 in radiation installations as well as for diagnostic and therapeutic patients in health ones. (author)

  1. A measurement of the absorption of liquid argon scintillation light by dissolved nitrogen at the part-per-million level

    International Nuclear Information System (INIS)

    Jones, B J P; Chiu, C S; Conrad, J M; Ignarra, C M; Katori, T; Toups, M

    2013-01-01

    We report on a measurement of the absorption length of scintillation light in liquid argon due to dissolved nitrogen at the part-per-million (ppm) level. We inject controlled quantities of nitrogen into a high purity volume of liquid argon and monitor the light yield from an alpha source. The source is placed at different distances from a cryogenic photomultiplier tube assembly. By comparing the light yield from each position we extract the absorption cross section of nitrogen. We find that nitrogen absorbs argon scintillation light with strength of (1.51±0.15) × 10 −4 cm −1 ppm −1 , corresponding to an absorption cross section of (4.99±0.51) × 10 −21 cm 2 molecule −1 . We obtain the relationship between absorption length and nitrogen concentration over the 0 to 50 ppm range and discuss the implications for the design and data analysis of future large liquid argon time projection chamber (LArTPC) detectors. Our results indicate that for a current-generation LArTPC, where a concentration of 2 parts per million of nitrogen is expected, the attenuation length due to nitrogen will be 30±3 meters

  2. Measurements of the proton light output function of the organic liquid scintillator NE213 in several detectors

    Energy Technology Data Exchange (ETDEWEB)

    Hawkes, N.P.; Adams, J.M.; Bond, D.S.; Croft, S; Jarvis, O.N. E-mail: onj@jet.uk; Watkins, N

    2002-01-01

    When using an organic liquid scintillator such as NE213 for neutron spectrometry, the light output as a function of proton energy is needed in order to unfold the neutron spectrum from the scintillator's pulse height distribution. We have measured this function for several detectors over the range 1.5-16 MeV approximately, using monoenergetic neutrons from the Harwell 5 MV Van de Graaff accelerator. Results were obtained for a wide variety of sizes and shapes of the scintillator cell, and were found to be essentially in agreement within errors. The results were also compared with those of several other workers (amongst whom there is considerable disagreement). Below 10 MeV, there is excellent agreement with one worker and moderate or poor agreement with others; above 10 MeV, agreement is moderate in all cases. We conclude that workers wishing to unfold neutron spectra from NE213 pulse height distributions would be advised to make measurements with their own particular detector configuration, rather than use published functions.

  3. Discrimination of neutrons and γ-rays in liquid scintillators based of fuzzy c-means clustering

    International Nuclear Information System (INIS)

    Luo Xiaoliang; Liu Guofu; Yang Jun

    2011-01-01

    A novel method based on fuzzy c-means (FCM) clustering for the discrimination of neutrons and γ-rays in liquid scintillators was presented. The neutrons and γ-rays in the environment were firstly acquired by the portable real-time n-γ discriminator and then discriminated using fuzzy c-means clustering and pulse gradient analysis, respectively. By comparing the results with each other, it is shown that the discrimination results of the fuzzy c-means clustering are consistent with those of the pulse gradient analysis. The decrease in uncertainty and the improvement in discrimination performance of the fuzzy c-means clustering were also observed. (authors)

  4. Determination of 63Ni and 55Fe in nuclear waste samples using radiochemical separation and liquid scintillation counting

    DEFF Research Database (Denmark)

    Hou, Xiaolin; Frøsig Østergaard, L.; Nielsen, S.P.

    2005-01-01

    An analytical method for the determination of Ni-63 and Fe-55 in nuclear waste samples such as graphite, heavy concrete, aluminium and lead was developed. Different decomposition methods (i.e. ashing, acid digestion and alkali fusion) were investigated for the decomposition of the samples...... by extraction chromatography. The purified Ni-63 and Fe-55 was then measured by liquid scintillation counting. The chemical yields of the separation procedures for Fe-55 and Ni-63 are above 90% and the decontamination factors for all interfering radionuclides are more than 10(5). The detection limits...

  5. Results of low energy background measurements with the Liquid Scintillation Detector (LSD) of the Mont Blanc Laboratory

    Science.gov (United States)

    Aglietta, M.; Badino, G.; Bologna, G. F.; Castagnoli, C.; Fulgione, W.; Galeotti, P.; Saavedra, O.; Trinchero, G. C.; Vernetto, S.; Dadykin, V. L.

    1985-01-01

    The 90 tons liquid scintillation detector (LSD) is fully running since October 1984, at a depth of 5,200 hg/sq cm of standard rock underground. The main goal is to search for neutrino bursts from collapsing stars. The experiment is very sensitive to detect low energy particles and has a very good signature to gamma-rays from (n,p) reaction which follows the upsilon e + p yields n + e sup + neutrino capture. The analysis of data is presented and the preliminary results on low energy measurements are discussed.

  6. Results of low energy background measurements with the liquid scintillation detector (LSD) of the Mont Blanc Laboratory

    International Nuclear Information System (INIS)

    Aglietta, M.; Badino, G.; Bologna, G.F.

    1985-01-01

    The 90 tons liquid scintillation detector (LSD) has been fully running since October 1984 at a depth of 5,200 hg/sq cm of standard rock underground. The main goal is to search for neutrino bursts from collapsing stars. The experiment is very sensitive to detect low energy particles and has a very good signature to gamma rays from (n,p) reactions which follows the upsilon e + p yields n + e sup + neutrino capture. The analysis of data is presented and the preliminary results on low energy measurements are discussed. 1 ref

  7. Determining the level of gross alpha and beta radioactivity of water from Marilao river using liquid scintillation counter

    International Nuclear Information System (INIS)

    Cruz, J.; Magtaka, J.; Balisi, R.; Castaneda, Soledad; De Vero, J.

    2009-01-01

    This study aims to determine the level of gross alpha- and beta- radioactivity present in the Marilao River. Liquid Scintillation Counter was used to detect samples radioactivity. Water samples were taken along the different spots of Marilao River. The results showed that the radioactivity are below the Philippine National Standard for Drinking Water (PNSDW) which is 0.1 Bq/L for gross alpha activity and 1.0 Bq/L for gross beta activity set by the Dept. of Health. Hence water samples from Marilao River, is safe in terms of the level of radioactivity levels.(author)

  8. Chemical and colour quenching in liquid scintillation counting; Estudio de la extincion quimica y por color en centelleo liquido

    Energy Technology Data Exchange (ETDEWEB)

    Scott, P. E.; Grau, A.

    1987-07-01

    Chemical and colour quenching for H-3 and C-14 was studied. The method includes spectral analysis of colouring agents; methyl red, (4'-dimethylamine-azobenzene 2-carboxylic acid) dimethyl yellow (4'-dimethylamine-azobenzene) and malachite green (methane, bis .(4-dimethyl aminophenyl) - (phenyl)). External standard channels ratio was applied for the liquid scintillation counting of samples. The introduction of an isolated external standard seems to be a strong tool for the correction of chemical and colour quenching curves. (Author) 12 refs.

  9. Absolute measurement of ν/sub p/-bar for 252Cf by the large liquid scintillator tank technique

    International Nuclear Information System (INIS)

    Spencer, R.R.

    1979-01-01

    A vigorous effect to dispel the scandal of the approx. 2% dispersion in reported experimental values of 252 Cf ν-bar, the average number of neutrons emitted in spontaneous fission, has been underway over the past 5 years. The goal is to reduce the uncertainty in this fundamental parameter to the +- 0.25% level needed for reactor physics applications. Both new measurements and revaluation of older measurements are involved. At ORNL a new measurement is being carried out using the leage liquid scintillator neutron detector. Findings of the most recent experiment, incorporating improvements suggested in a preliminary study are discussed. 6 figures, 2 tables

  10. A comparative study using liquid scintillation counting to determine 63Ni in low and intermediate level radioactive waste

    International Nuclear Information System (INIS)

    Gautier, Celine; Colin, Christele; Garcia, Cecile

    2016-01-01

    A comparative study using liquid scintillation counting was performed to measure 63 Ni in low and intermediate level radioactive waste. Three dimethylglyoxime (DMG)-based radiochemical procedures (solvent extraction, precipitation, extraction chromatography) were investigated, the solvent extraction method being considered as the reference method. Theoretical speciation calculations enabled to better understand the chemical reactions involved in the three protocols and to optimize them. In comparison to the method based on DMG precipitation, the method based on extraction chromatography allowed to achieve the best results in one single step in term of recovery yield and accuracy for various samples. (author)

  11. Evaluation of biodegradable and nonbiodegradable liquid scintillation cocktails used for tritium-in-water and urine analyses

    International Nuclear Information System (INIS)

    Haddock, J.A.

    1992-11-01

    The performance of a number of liquid scintillation cocktails was evaluated for quench resistance, sample capacity, cost, waste reduction and limit of detection. Directed towards the specific applications of counting tritium in water and urine samples, this study illustrated the potential of the newer, biodegradable cocktails, which mostly exhibited comparable or superior counting performance to the traditional cocktails. Reduced cocktail volumes and the use of mini vials is recommended for medium-load cocktails used for routine urine or water analyses, since a significant decrease in the volume of waste generated in Canadian nuclear facilities would result. (Author) (13 refs., 5 tabs., 44 figs.)

  12. Measurement of low-level beta activity of samples in liquid state using plastic scintillator vials

    International Nuclear Information System (INIS)

    Wezranowski, E.; Panczyk, E.; Radwan, M.

    1977-01-01

    Plastic scintillation vials having walls from a plastic scintillator and the bottom from perspex were used. Wall thickness was 0.8 to 3 mm. The solution radioactivity was measured by a scintillation beta spectrometer. The total measurement errors were found for the following radionuclides: 14 C +-3.7%; 204 Tl +-3%; 32 P +-2.8%; 137 Cs +-2%, and 72 Ga +-5%. Detection efficiency was found to decrease rapidly with the solution layer thickness. For a solution thickness of 0.2 mm the highest detection efficiency was observed with the 4% measurement error. Linear dependence was found of detection efficiency on beta energy. For a solution layer thickness of 0.2 mm the minimum measurable activities were determined to be 30.3 pCi for 14 C and 2.12 pCi for 32 P. The use of the above vials permits quick and simple measurement without sample chemical preparation. (J.P.)

  13. Development of portable Liquid Scintillation counters for on-site primary measurement of radionuclides using the Triple-to-Double Coincidence Ratio method

    International Nuclear Information System (INIS)

    Cassette, P.; Capogni, M.; De Felice, P.; Johansson, L.; Sephton, J.; Kossert, K.; Naehle, O.

    2013-06-01

    The Triple-to-Double Coincidence Ratio (TDCR) method in Liquid Scintillation counting (LSC) is a primary radionuclide standardization method widely used in National Metrology laboratories and was primarily developed for the activity measurement of beta emitters. It is based on liquid scintillation: the light is detected by three photomultipliers (PM) and the detection efficiency is evaluated by using a model which uses the ratio of triple-to-double coincidences between the PM tubes. Up to now, most of current TDCR systems were locally-made metrology instruments neither aimed at nor suitable for in-situ measurements. In the framework of the European Metrofission project, a work package was dedicated to the realisation of miniature self-calibrated primary TDCR systems, which are state-of-the-art, for use on-site. The challenge was to develop a versatile portable, table-top designed instrument, from this metrology device. This implied improvements for the miniaturisation of the detection chamber, for the miniaturisation of electronic modules by exploring the possibilities of digital treatment, and for the validation of models and extension of them to nuclides with special beta spectrum shapes, to nuclides with complex decay schemes including many gamma-rays and to nuclides with higher atomic number decaying by electron capture. Four prototypes of counters were built by the Metrofission partners ENEA (Italy), LNHB (France), NPL (UK) and PTB (Germany) using various technical approaches. The paper describes these prototypes and provides some details on the choice of the technical options concerning the design of the optical chamber, of the photodetectors and of the acquisition system. (authors)

  14. Organic liquid scintillation detectors for on-the-fly neutron/gamma alarming and radionuclide identification in a pedestrian radiation portal monitor

    Science.gov (United States)

    Paff, Marc Gerrit; Ruch, Marc L.; Poitrasson-Riviere, Alexis; Sagadevan, Athena; Clarke, Shaun D.; Pozzi, Sara

    2015-07-01

    We present new experimental results from a radiation portal monitor based on the use of organic liquid scintillators. The system was tested as part of a 3He-free radiation portal monitor testing campaign at the European Commission's Joint Research Centre in Ispra, Italy, in February 2014. The radiation portal monitor was subjected to a wide range of test conditions described in ANSI N42.35, including a variety of gamma-ray sources and a 20,000 n/s 252Cf source. A false alarm test tested whether radiation portal monitors ever alarmed in the presence of only natural background. The University of Michigan Detection for Nuclear Nonproliferation Group's system triggered zero false alarms in 2739 trials. It consistently alarmed on a variety of gamma-ray sources travelling at 1.2 m/s at a 70 cm source to detector distance. The neutron source was detected at speeds up to 3 m/s and in configurations with up to 8 cm of high density polyethylene shielding. The success of on-the-fly radionuclide identification varied with the gamma-ray source measured as well as with which of two radionuclide identification methods was used. Both methods used a least squares comparison between the measured pulse height distributions to library spectra to pick the best match. The methods varied in how the pulse height distributions were modified prior to the least squares comparison. Correct identification rates were as high as 100% for highly enriched uranium, but as low as 50% for 241Am. Both radionuclide identification algorithms produced mixed results, but the concept of using liquid scintillation detectors for gamma-ray and neutron alarming in radiation portal monitor was validated.

  15. Measurement of isotopic uranium in water for compliance monitoring by liquid scintillation counting with alpha/beta discrimination

    International Nuclear Information System (INIS)

    Venso, E.A.S.

    1993-01-01

    A simple and inexpensive method is described for analysis of uranium (U) activity and mass in water by liquid scintillation counting using α/β discrimination. This method appears to offer a solution to the need for an inexpensive protocol for monitoring U activity and mass simultaneously and an alternative to the potential inaccuracy involved when depending on the mass-to-activity conversion factor or activity screen. U is extracted virtually quantitatively into 20 ml extractive scintillator from a 1-ell aliquot of water acidified to less than pH 2. After phase separation, the sample is counted for a 20-minute screening count with a minimum detection level of 0.27 pCi ell -1 . α-particle emissions from the extracted U are counted with close to 100% efficiency with a Beckman LS6000 LL liquid scintillation counter equipped with pulse-shape discrimination electronics. Samples with activities higher than 10 pCi ell -1 are recounted for 500-1000 minutes for isotopic analysis. Isotopic analysis uses events that are automatically stored in spectral files and transferred to a computer during assay. The data can be transferred to a commercially available spreadsheet and retrieved for examination or data manipulation. Values for three readily observable spectral features can be rapidly identified by data examination and substituted into a simple formula to obtain 234 U/ 238 U ratio for most samples. U mass is calculated by substituting the isotopic ratio value into a simple equation. The utility of this method for the proposed compliance monitoring of U in public drinking water supplies was field tested with a survey of drinking water from Texas supplies that had previously been known to contain elevated levels of gross α activity. U concentrations in 32 samples from 27 drinking water supplies ranged from 0.26 to 65.5 pCi ell -1 , with seven samples exceeding the proposed Maximum Contaminant Level

  16. Radiocarbon dating of archaeological samples (sambaqui) using CO(2) absorption and liquid scintillation spectrometry of low background radiation.

    Science.gov (United States)

    Mendonça, Maria Lúcia T G; Godoy, José M; da Cruz, Rosana P; Perez, Rhoneds A R

    2006-01-01

    Sambaqui means, in the Tupi language, a hill of shells. The sambaquis are archaeological sites with remains of pre-historical Brazilian occupation. Since the sambaqui sites in the Rio de Janeiro state region are older than 10,000 years, the applicability of CO(2) absorption on Carbo-sorb and (14)C determination by counting on a low background liquid scintillation counter was tested. In the present work, sambaqui shells were treated with H(3)PO(4) in a closed vessel in order to generate CO(2). The produced CO(2) was absorbed on Carbo-sorb. On saturation about 0.6g of carbon, as CO(2), was mixed with commercial liquid scintillation cocktail (Permafluor), and the (14)C activity determined by counting on a low background counter, Packard Tricarb 3170 TR/SL, for a period of 1000 mins to enable detection of a radiocarbon age of 22,400 BP. But only samples with ages up to 3500 BP were submitted to the method because the samples had been collected in the municipality of Guapimirim, in archaeological sambaqui-type sites belonging to this age range. The same samples were sent to the (14)C Laboratory of the Centro de Energia Nuclear na Agricultura (CENA/USP) where similar results were obtained.

  17. Development of large-volume, high-resolution tracking detectors based on capillaries filled with liquid scintillator

    International Nuclear Information System (INIS)

    Buontempo, S.; Fabre, J.P.; Frenkel, A.; Gregoire, G.; Hoepfner, K.; Konijn, J.; Kozarenko, E.; Kreslo, I.; Kushnirenko, A.; Martellotti, G.; Michel, L.; Mondardini, M.R.; Penso, G.; Siegmund, W.P.; Strack, R.; Tyukov, V.; Vasilchenko, V.; Vilain, P.; Wilquet, G.; Winter, K.; Wong, H.; Zymin, K.

    1995-01-01

    Searches for the decay of short-lived particles require real time, high-resolution tracking in active targets, which in the case of neutrino physics should be of large volume. The possibility of achieving this by using glass capillaries filled with organic liquid scintillator is being investigated in the framework of the CHORUS experiment at CERN. In this paper, after outlining the application foreseen, advances in the tracking technique are discussed and results from tests are reported. An active target of dimensions 180x2x2 cm 3 has been assembled from capillaries with 20 μm diameter pores. The readout scheme currently in operation allows the reading of similar 5x10 5 channels using a single chain of image intensifiers having a resolution of σ similar 20 μm. Following the development of new liquid scintillators and purification methods an attenuation length of similar 3 m has been obtained. This translates into a hit density of 3.5 per mm for a minimum-ionizing particle that crosses the active target at a distance of 1 m from the readout end. (orig.)

  18. New procedure for the determination of radium in water by extraction of radon and application of integral counting with a liquid scintillation counter

    Energy Technology Data Exchange (ETDEWEB)

    Horiuchi, K [Tokyo Metropolitan Univ. (Japan). Faculty of Science; Murakami, Y [Kitasato Univ. (Japan). School of Hygienic Sciences

    1981-05-01

    A new Ra determination method is devised, storing the sample in a glass bottle with a Teflon stopper in an upside-down position, extracting Rn with liquid scintillator solution and combining integral counting with a liquid scintillation counter. This method realizes a high sensitivity of 5 x 10/sup -13/ Ci Ra, eliminates the tedious procedure of transferring Rn through the vacuum system to the detector and makes possible repeated determinations of Ra on the same sample without any further chemical treatment except extraction.

  19. Liquid argon scintillation detection utilizing wavelength-shifting plates and light guides

    Science.gov (United States)

    Howard, B.

    2018-02-01

    In DUNE, the event timing provided by the detection of the relatively prompt scintillation photons will improve spatial resolution in the drift direction of the time-projection chamber (TPC) and is especially useful for non-beam physics topics such as supernova neutrinos and nucleon decay. The baseline design for the first 10kt single phase TPC fits the photon detector system in the natural gap between the wire planes of adjacent TPC volumes. A prototype photon detector design utilizes wavelength-shifter coated plates to convert the vacuum ultraviolet scintillation light to the optical and commercially-produced wavelength-shifting light guides to trap some of this light and transport it to an array of silicon photomultipliers at the end. This system and the testing performed to characterize the system and determine the efficiency are discussed.

  20. The determination of 14CO2 in breath by liquid scintillation counting

    International Nuclear Information System (INIS)

    Ozker, K.; East, B.W.; Boddy, K.

    1977-03-01

    A sensitive method of sampling and measuring the specific activity of 14 CO 2 in expired breath in order to evaluate the metabolic pathways of 14 C-labelled compounds has been devised. 14 CO 2 is blown through a short plastic tube, attached to a drier, into a scintillation vial containing hyamine hydroxide and ethanol. 14 CO 2 was generated to the end-point of neutralization of hyamine hydroxide, indicated by the decolourisation of phenolphthalein. 14 CO 2 was counted after mixing the hyamine hydroxide and ethanol with 15ml toluene scintillation solution. The specific activity of 14 CO 2 from the samples was compared with that of solutions of known activity. The method is sensitive for clinical applications and can be performed at a patient's bedside. (U.K.)

  1. Liquid Argon Scintillation Detection Utilizing Wavelength-Shifting Plates and Light Guides

    Energy Technology Data Exchange (ETDEWEB)

    Howard, B. [Indiana U.

    2018-02-06

    In DUNE, the event timing provided by the detection of the relatively prompt scintillation photons will improve spatial resolution in the drift direction of the time-projection chamber (TPC) and is especially useful for non-beam physics topics such as supernova neutrinos and nucleon decay. The baseline design for the first 10kt single phase TPC fits the photon detector system in the natural gap between the wire planes of adjacent TPC volumes. A prototype photon detector design utilizes wavelength-shifter coated plates to convert the vacuum ultraviolet scintillation light to the optical and commercially-produced wavelength-shifting light guides to trap some of this light and transport it to an array of silicon photomultipliers at the end. This system and the testing performed to characterize the system and determine the efficiency are discussed.

  2. Calculation of the detection efficiency in liquid scintillators. II. Single positron emitters

    International Nuclear Information System (INIS)

    Grau Malonda, A.; Garcia Torano, E.

    1982-01-01

    Counting efficiency as a function of the figure of merit for 30 positron emitters has been computed from the positron energy spectrum. Only the efficiency contribution of positrons has been taken into consideration. The contribution of the annihilation photons depending on the volume of the scintillator will be investigated in a near future. Efficiency vs figure of merit is plotted and tabulated. (Author) 19 refs

  3. Characteristic parameters in the measurement of (14)C of biobased diesel fuels by liquid scintillation.

    Science.gov (United States)

    Idoeta, R; Pérez, E; Herranz, M; Legarda, F

    2014-11-01

    The direct method based on the radiocarbon content present in modern-day materials used for the quantification of the renewable origin component in diesel has been analysed in order to establish the best sample preparation and measuring conditions that minimise the limit of detection. The scintillation cocktail and the diesel/cocktail ratio have been optimised. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Determination of the proton and alpha-particle light-response functions for the KamLAND, BC-501A and BC-517H liquid scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Braizinha, B. [Department of Physics and Astronomy, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599 (United States); Triangle Universities Nuclear Laboratory, Durham, NC 27708 (United States); Esterline, J.H. [Triangle Universities Nuclear Laboratory, Durham, NC 27708 (United States); Department of Physics, Duke University, Durham, NC 27708 (United States); Karwowski, H.J. [Department of Physics and Astronomy, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599 (United States); Triangle Universities Nuclear Laboratory, Durham, NC 27708 (United States); Tornow, W., E-mail: tornow@tunl.duke.ed [Triangle Universities Nuclear Laboratory, Durham, NC 27708 (United States); Department of Physics, Duke University, Durham, NC 27708 (United States)

    2010-11-21

    A cylindrical 5.1 cmx5.1 cm scintillator cell filled with the KamLAND liquid scintillator has been exposed to monoenergetic neutron beams produced via the {sup 2}H(d,n){sup 3}He reaction to measure the proton light-response function for energies up to 10 MeV. Using Birks' recipe, the {alpha}-particle light-response function was derived from these data. The same method was applied to the BC-501A and BC-517H liquid scintillators to check on the systematic accuracy of the present data. The proton and {alpha}-particle light-response functions are needed to correct the KamLAND antineutrino prompt energy spectrum for background effects caused by the reaction {sup 13}C({alpha},n){sup 16}O. Especially, the geo-antineutrino energy regime measured in the KamLAND experiment is contaminated by background events from this reaction.

  5. Determination of the proton and alpha-particle light-response functions for the KamLAND, BC-501A and BC-517H liquid scintillators

    International Nuclear Information System (INIS)

    Braizinha, B.; Esterline, J.H.; Karwowski, H.J.; Tornow, W.

    2010-01-01

    A cylindrical 5.1 cmx5.1 cm scintillator cell filled with the KamLAND liquid scintillator has been exposed to monoenergetic neutron beams produced via the 2 H(d,n) 3 He reaction to measure the proton light-response function for energies up to 10 MeV. Using Birks' recipe, the α-particle light-response function was derived from these data. The same method was applied to the BC-501A and BC-517H liquid scintillators to check on the systematic accuracy of the present data. The proton and α-particle light-response functions are needed to correct the KamLAND antineutrino prompt energy spectrum for background effects caused by the reaction 13 C(α,n) 16 O. Especially, the geo-antineutrino energy regime measured in the KamLAND experiment is contaminated by background events from this reaction.

  6. Development and Validation of Liquid Chromatography- Mass ...

    African Journals Online (AJOL)

    HP

    Method: A novel liquid chromatography–tandem mass spectrometry method for the quantitative determination of naproxen in human K2-EDTA plasma in negative ion mode was employed ..... Practice and Applications of Bio-analytical Method.

  7. Validation of GEANT4 Monte Carlo Models with a Highly Granular Scintillator-Steel Hadron Calorimeter

    CERN Document Server

    Adloff, C.; Blaising, J.J.; Drancourt, C.; Espargiliere, A.; Gaglione, R.; Geffroy, N.; Karyotakis, Y.; Prast, J.; Vouters, G.; Francis, K.; Repond, J.; Schlereth, J.; Smith, J.; Xia, L.; Baldolemar, E.; Li, J.; Park, S.T.; Sosebee, M.; White, A.P.; Yu, J.; Buanes, T.; Eigen, G.; Mikami, Y.; Watson, N.K.; Mavromanolakis, G.; Thomson, M.A.; Ward, D.R.; Yan, W.; Benchekroun, D.; Hoummada, A.; Khoulaki, Y.; Apostolakis, J.; Dotti, A.; Folger, G.; Ivantchenko, V.; Uzhinskiy, V.; Benyamna, M.; Cârloganu, C.; Fehr, F.; Gay, P.; Manen, S.; Royer, L.; Blazey, G.C.; Dyshkant, A.; Lima, J.G.R.; Zutshi, V.; Hostachy, J.Y.; Morin, L.; Cornett, U.; David, D.; Falley, G.; Gadow, K.; Gottlicher, P.; Gunter, C.; Hermberg, B.; Karstensen, S.; Krivan, F.; Lucaci-Timoce, A.I.; Lu, S.; Lutz, B.; Morozov, S.; Morgunov, V.; Reinecke, M.; Sefkow, F.; Smirnov, P.; Terwort, M.; Vargas-Trevino, A.; Feege, N.; Garutti, E.; Marchesini, I.; Ramilli, M.; Eckert, P.; Harion, T.; Kaplan, A.; Schultz-Coulon, H.Ch.; Shen, W.; Stamen, R.; Bilki, B.; Norbeck, E.; Onel, Y.; Wilson, G.W.; Kawagoe, K.; Dauncey, P.D.; Magnan, A.M.; Bartsch, V.; Wing, M.; Salvatore, F.; Alamillo, E.Calvo; Fouz, M.C.; Puerta-Pelayo, J.; Bobchenko, B.; Chadeeva, M.; Danilov, M.; Epifantsev, A.; Markin, O.; Mizuk, R.; Novikov, E.; Popov, V.; Rusinov, V.; Tarkovsky, E.; Kirikova, N.; Kozlov, V.; Smirnov, P.; Soloviev, Y.; Buzhan, P.; Ilyin, A.; Kantserov, V.; Kaplin, V.; Karakash, A.; Popova, E.; Tikhomirov, V.; Kiesling, C.; Seidel, K.; Simon, F.; Soldner, C.; Szalay, M.; Tesar, M.; Weuste, L.; Amjad, M.S.; Bonis, J.; Callier, S.; Conforti di Lorenzo, S.; Cornebise, P.; Doublet, Ph.; Dulucq, F.; Fleury, J.; Frisson, T.; van der Kolk, N.; Li, H.; Martin-Chassard, G.; Richard, F.; de la Taille, Ch.; Poschl, R.; Raux, L.; Rouene, J.; Seguin-Moreau, N.; Anduze, M.; Boudry, V.; Brient, J-C.; Jeans, D.; Mora de Freitas, P.; Musat, G.; Reinhard, M.; Ruan, M.; Videau, H.; Bulanek, B.; Zacek, J.; Cvach, J.; Gallus, P.; Havranek, M.; Janata, M.; Kvasnicka, J.; Lednicky, D.; Marcisovsky, M.; Polak, I.; Popule, J.; Tomasek, L.; Tomasek, M.; Ruzicka, P.; Sicho, P.; Smolik, J.; Vrba, V.; Zalesak, J.; Belhorma, B.; Ghazlane, H.; Takeshita, T.; Uozumi, S.; Gotze, M.; Hartbrich, O.; Sauer, J.; Weber, S.; Zeitnitz, C.

    2013-01-01

    Calorimeters with a high granularity are a fundamental requirement of the Particle Flow paradigm. This paper focuses on the prototype of a hadron calorimeter with analog readout, consisting of thirty-eight scintillator layers alternating with steel absorber planes. The scintillator plates are finely segmented into tiles individually read out via Silicon Photomultipliers. The presented results are based on data collected with pion beams in the energy range from 8GeV to 100GeV. The fine segmentation of the sensitive layers and the high sampling frequency allow for an excellent reconstruction of the spatial development of hadronic showers. A comparison between data and Monte Carlo simulations is presented, concerning both the longitudinal and lateral development of hadronic showers and the global response of the calorimeter. The performance of several GEANT4 physics lists with respect to these observables is evaluated.

  8. Study of n-γ discrimination by digital charge comparison method for a large volume liquid scintillator

    International Nuclear Information System (INIS)

    Moszynski, M.; Costa, G.J.; Guillaume, G.; Heusch, B.; Huck, A.; Ring, C.; Bizard, G.; Durand, D.; Peter, J.; Tamain, B.; El Masri, Y.; Hanappe, F.

    1992-01-01

    The study of the n-γ discrimination for a large 41 volume BC501A liquid scintillator coupled to a 130 mm diameter XP4512B photomultiplier was carried out by digital charge comparison method. A very good n-γ discrimination down to 100 keV of recoil electron energy was achieved. The measured relative intensity of the charge integrated at the slow component of the scintillation pulse and the photoelectron yield of the tested counter allow the factor of merit of the n-γ discrimination spectra to be calculated and to be compared with those measured experimentally. This shows that the main limitation of the n-γ discrimination is associated with the statistical fluctuation of the photoelectron number at the slow component. A serious effect of the distortion in the cable used to send the photomultiplier pulse to the electronics for the n-γ discrimination was studied. This suggests that the length of RG58 cable should be limited to about 40 m to preserve a high quality n-γ discrimination. (orig.)

  9. Alpha liquid-scintillation spectrometry used for the measurement of uranium/thorium-disequilibria in soil samples

    International Nuclear Information System (INIS)

    Fueeg, B.; Tschachtli, T.; Kraehenbuehl, U.

    1997-01-01

    For the measurements of low-level radioactivity of natural samples. It is of interest to have a system with high counting efficiency. Alpha liquid-scintillation spectrometry is attractive, because it offers a 4 π geometry. Some chemical separation can be obtained using extractive scintillators. Due to quenching problems for natural samples, additional separation power is needed. A new sample preparation method was developed employing extraction chromatographic resin for measuring 238 U, 234 U, 232 Th, 230 Th, 228 Th and 226 Ra in soil samples, without using any uranium- or thorium-tracer for determining the chemical yields. This method was tested by analyzing the two different reference materials, IAEA-375, soil from Tschernobyl, as well as IAEA SDA-1, a deep-sea sediment with a high calcium content. For all analyzed radionuclides the recoveries were better than 90% with errors (confidence level of 95%) smaller than 5%. The minimal detectable concentration ranges between 0.2 and 0.8 Bq/kg, based on a one gram aliquot of sample and 80'000 seconds counting time. (orig.)

  10. A Procedure for the Sequential Determination of Radionuclides in Environmental Samples. Liquid Scintillation Counting and Alpha Spectrometry for 90Sr, 241Am and Pu Radioisotopes

    International Nuclear Information System (INIS)

    2014-01-01

    Since 2004, IAEA activities related to the terrestrial environment have aimed at the development of a set of procedures to determine radionuclides in environmental samples. Reliable, comparable and ‘fit for purpose’ results are an essential requirement for any decision based on analytical measurements. For the analyst, tested and validated analytical procedures are extremely important tools for the production of analytical data. For maximum utility, such procedures should be comprehensive, clearly formulated and readily available for reference to both the analyst and the customer. This publication describes a combined procedure for the sequential determination of 90 Sr, 241 Am and Pu radioisotopes in environmental samples. The method is based on the chemical separation of strontium, americium and plutonium using ion exchange chromatography, extraction chromatography and precipitation followed by alpha spectrometric and liquid scintillation counting detection. The method was tested and validated in terms of repeatability and trueness in accordance with International Organization for Standardization (ISO) guidelines using reference materials and proficiency test samples. Reproducibility tests were performed later at the IAEA Terrestrial Environment Laboratory. The calculations of the massic activity, uncertainty budget, decision threshold and detection limit are also described in this publication. The procedure is introduced for the determination of 90 Sr, 241 Am and Pu radioisotopes in environmental samples such as soil, sediment, air filter and vegetation samples. It is expected to be of general use to a wide range of laboratories, including the Analytical Laboratories for the Measurement of Environmental Radioactivity (ALMERA) network for routine environmental monitoring purposes

  11. A Procedure for the Sequential Determination of Radionuclides in Phosphogypsum Liquid Scintillation Counting and Alpha Spectrometry for 210Po, 210Pb, 226Ra, Th and U Radioisotopes

    International Nuclear Information System (INIS)

    2014-01-01

    Since 2004, the Environment Programme of the IAEA has included activities aimed at the development of a set of procedures for the determination of radionuclides in terrestrial environmental samples. Reliable, comparable and 'fit for purpose' results are essential requirements for any decision based on analytical measurements. For the analyst, tested and validated analytical procedures are extremely important tools for the production of such analytical data. For maximum utility, such procedures should be comprehensive, clearly formulated, and readily available to both the analyst and the customer for reference. In this publication, a combined procedure for the sequential determination of 210Po, 210Pb, 226Ra, Th and U radioisotopes in phosphogypsum is described. The method is based on the dissolution of small amounts of phosphogypsum by microwave digestion, followed by sequential separation of 210Po, 210Pb, Th and U radioisotopes by selective extraction chromatography using Sr, TEVA and UTEVA resins. Radium-226 is separated from interfering elements using Ba(Ra)SO4 co-precipitation. Lead-210 is determined by liquid scintillation counting. The alpha source of 210Po is prepared by autodeposition on a silver plate. The alpha sources of Th and U are prepared by electrodeposition on a stainless steel plate. A comprehensive methodology for the calculation of results, including the quantification of measurement uncertainty, was also developed. The procedure is introduced as a recommended procedure and validated in terms of trueness, repeatability and reproducibility in accordance with ISO guidelines

  12. A sub-boiling distillation method for the preparation of low carbon content water from urine samples for tritium measurement by liquid scintillation counting

    International Nuclear Information System (INIS)

    Nogawa, Norio; Makide, Yoshihiro

    1999-01-01

    A new preparation method was developed for obtaining low carbon content water from urine samples for the measurement of tritium by a liquid scintillation counter. The method uses a simple and convenient subboiling distillation bottle. Many urine samples have been purified by this method and the change of tritium level in a tritium-handling radiation-worker was observed

  13. Counting efficiency for liquid scintillator systems with a single multiplier phototube; Eficiencia de recuento en espectrometros de centelleo con un solo fotomultiplicador

    Energy Technology Data Exchange (ETDEWEB)

    Grau Malonda, A; Garcia-Torano, E

    1984-07-01

    In this paper counting efficiency as a function of a free parameter (the figure of merit) has been computed. The results are applicable to liquid scintillator systems with a single multiplier phototube. Tables of counting efficiency for 62 pure beta emitters are given for figures of merit in the range 0.25 to 50. (Author) 16 refs.

  14. 14C measurement: effect of variations in sample preparation and storage on the counting efficiency for 14C using a carbo-sorb/permafluor E+ liquid scintillation cocktail

    International Nuclear Information System (INIS)

    Kramer, S.J.; Milton, G.M.; Repta, C.J.W.

    1995-06-01

    The effect of variations in sample preparation and storage on the counting efficiency for 14 C using a Carbo-Sorb/PermafluorE+ liquid scintillation cocktail has been studied, and optimum conditions are recommended. (author). 2 refs., 2 tabs., 4 figs

  15. Neutron/gamma discrimination employing the power spectrum analysis of the signal from the liquid scintillator BC501A

    International Nuclear Information System (INIS)

    Luo, X.L.; Wang, Y.K; Yang, J.; Liu, G.; Lin, C.B.; Hu, Q.Q.; Peng, J.X.

    2013-01-01

    A digital method for the discrimination of neutron and γ-ray events based on analyzing the power spectra of the signals from a BC501A liquid scintillator detector was presented and investigated in this paper. In order to evaluate the feasibility of this novel pulse shape discrimination method, a 5GSample/s 8-bit oscilloscope was used to acquire waveforms for n/γ discrimination. Furthermore, the performance of this novel n/γ discrimination method was compared with that of a widely used method called the reference-pulses method which averaged a large number of neutron and γ-ray pulses to obtain the reference-pulse as the criterion for n/γ discrimination. The results showed that the proposed method performed well over the reference-pulses method, which was verified by the considerable decrease in the error rate of n/γ discrimination and the improvement of the Figure of Merit

  16. Constructing experimental devices for half-ton synthesis of gadolinium-loaded liquid scintillator and its performance

    Science.gov (United States)

    Park, Young Seo; Jang, Yeong Min; Joo, Kyung Kwang

    2018-04-01

    This paper describes in brief features of various experimental devices constructed for half-ton synthesis of gadolinium(Gd)-loaded liquid scintillator (GdLS) and also includes the performances and detailed chemical and physical results of a 0.5% high-concentration GdLS. Various feasibility studies on useful apparatus used for loading Gd into solvents have been carried out. The transmittance, Gd concentration, density, light yield, and moisture content were measured for quality control. We show that with the help of adequate automated experimental devices and tools, it is possible to perform ton scale synthesis of GdLS at moderate laboratory scale without difficulty. The synthesized GdLS was satisfactory to meet chemical, optical, and physical properties and various safety requirements. These synthesizing devices can be expanded into massive scale next-generation neutrino experiments of several hundred tons.

  17. Measurement of 226Ra in water and 222Rn in water and air by liquid scintillation counting

    International Nuclear Information System (INIS)

    Schoenhofer, F.

    1992-01-01

    In the Austrian province of Lower Austria a comprehensive programme for measurement of 222 Rn and 226 Ra in drinking water was conducted. A simple liquid scintillation counting (LSC) method was used which gives a LLD of 30 mBq per litre for 226 Ra without any chemical separation. Results are presented and the health significance is discussed. For 222 Rn in air a commercially available simple charcoal system with LSC was used. The system was tested in a house with elevated radon concentration under normal living conditions. During relatively short 2-day periods a maximum deviation of ± 30% from the monthly mean value was found. The advantages of LSC are that the procedures are very simple and cheap. (author)

  18. Standardization of {sup 241}Am by digital coincidence counting, liquid scintillation counting and defined solid angle counting

    Energy Technology Data Exchange (ETDEWEB)

    Balpardo, C., E-mail: balpardo@cae.cnea.gov.a [Laboratorio de Metrologia de Radioisotopos, CNEA, Buenos Aires (Argentina); Capoulat, M.E.; Rodrigues, D.; Arenillas, P. [Laboratorio de Metrologia de Radioisotopos, CNEA, Buenos Aires (Argentina)

    2010-07-15

    The nuclide {sup 241}Am decays by alpha emission to {sup 237}Np. Most of the decays (84.6%) populate the excited level of {sup 237}Np with energy of 59.54 keV. Digital coincidence counting was applied to standardize a solution of {sup 241}Am by alpha-gamma coincidence counting with efficiency extrapolation. Electronic discrimination was implemented with a pressurized proportional counter and the results were compared with two other independent techniques: Liquid scintillation counting using the logical sum of double coincidences in a TDCR array and defined solid angle counting taking into account activity inhomogeneity in the active deposit. The results show consistency between the three methods within a limit of a 0.3%. An ampoule of this solution will be sent to the International Reference System (SIR) during 2009. Uncertainties were analysed and compared in detail for the three applied methods.

  19. Attenuation length measurements of a liquid scintillator with LabVIEW and reliability evaluation of the device

    International Nuclear Information System (INIS)

    Gao Long; Yu Boxiang; Ding Yayun

    2013-01-01

    An attenuation length measurement device was constructed using an oscilloscope and LabVIEW for signal acquisition and processing. The performance of the device has been tested in a variety of ways. The test results show that the set-up has a good stability and high precision (sigma/mean reached 0.4 percent). Besides, the accuracy of the measurement system will decrease by about 17 percent if a filter is used. The attenuation length of a gadolinium-loaded liquid scintillator (Gd-LS) was measured as 15.10±0.35 m where Gd-LS was heavily used in the Daya Bay Neutrino Experiment. In addition, one method based on the Beer-Lambert law was proposed to investigate the reliability of the measurement device, the R-square reached 0.9995. Moreover, three purification methods for Linear Alkyl Benzene (LAB) production were compared in the experiment. (authors)

  20. Water quality - Determination of tritium activity concentration - Liquid scintillation counting method (International Standard Publication ISO 9698:1989)

    International Nuclear Information System (INIS)

    Stefanik, J.

    1999-01-01

    This International Standard specifies a method for the determination of tritiated water ([ 3 H]H 2 O) activity concentration in water by liquid scintillation counting. The method is applicable to all types of water including seawater with tritium activity concentrations of up to 10 6 Bq/m 3 when using 20 ml counting vials. Below tritium activity concentrations of about 5 x 10 4 Bq/m 3[ 8], a prior enrichment step and/or the measurement of larger sample volumes can significantly improve the accuracy of the determination and lower the limit of detection. Tritium activity concentrations higher than 10 6 Bq/m 3 may be determined after appropriate dilution with distilled water of proven low tritium content. An alternative method for the determination of these higher activities involves increasing the tritium activity concentrations of the internal standard solution. The method is not applicable to the analysis of organically bound tritium; its determination requires an oxidative digestion

  1. Results from a combined test of an electromagnetic liquid argon calorimeter with a hadronic scintillating-tile calorimeter

    CERN Document Server

    Ajaltouni, Ziad J; Alifanov, A; Amaral, P; Ambrosini, G; Amorim, A; Anderson, K J; Astvatsaturov, A R; Aubert, Bernard; Augé, E; Autiero, D; Azuelos, Georges; Badaud, F; Baisin, L; Battistoni, G; Bazan, A; Bee, C P; Bellettini, Giorgio; Berglund, S R; Berset, J C; Blaj, C; Blanchot, G; Blucher, E; Bogush, A A; Bohm, C; Boldea, V; Borisov, O N; Bosman, M; Bouhemaid, N; Brette, P; Bromberg, C; Brossard, M; Budagov, Yu A; Buono, S; Calôba, L P; Camin, D V; Canton, B; Casado, M P; Cavalli, D; Cavalli-Sforza, M; Cavasinni, V; Chadelas, R; Chase, Robert L; Chekhtman, A; Chevaleyre, J C; Chevalley, J L; Chirikov-Zorin, I E; Chlachidze, G; Chollet, J C; Cobal, M; Cogswell, F; Colas, Jacques; Collot, J; Cologna, S; Constantinescu, S; Costa, G; Costanzo, D; Cozzi, L; Crouau, M; Dargent, P; Daudon, F; David, M; Davidek, T; Dawson, J; De, K; de La Taille, C; Del Prete, T; Depommier, P; de Saintignon, P; De Santo, A; Dinkespiler, B; Di Girolamo, B; Dita, S; Dolejsi, J; Dolezal, Z; Downing, R; Dugne, J J; Duval, P Y; Dzahini, D; Efthymiopoulos, I; Errede, D; Errede, S; Etienne, F; Evans, H; Fassnacht, P; Fedyakin, N N; Ferrari, A; Ferreira, P; Ferrer, A; Flaminio, Vincenzo; Fouchez, D; Fournier, D; Fumagalli, G; Gallas, E J; Gaspar, M; Gianotti, F; Gildemeister, O; Gingrich, D M; Glagolev, V V; Golubev, V B; Gómez, A; González, J; Gordon, H A; Grabskii, V; Hakopian, H H; Haney, M; Hellman, S; Henriques, A; Holmgren, S O; Honoré, P F; Hostachy, J Y; Huston, J; Ivanyushenkov, Yu M; Jézéquel, S; Johansson, E K; Jon-And, K; Jones, R; Juste, A; Kakurin, S; Karapetian, G V; Karyukhin, A N; Khokhlov, Yu A; Klioukhine, V I; Kolomoets, V; Kopikov, S V; Kostrikov, M E; Kovtun, V E; Kukhtin, V V; Kulagin, M; Kulchitskii, Yu A; Laborie, G; Lami, S; Lapin, V; Lebedev, A; Lefebvre, M; Le Flour, T; Leitner, R; León-Florián, E; Leroy, C; Le Van-Suu, A; Li, J; Liba, I; Linossier, O; Lokajícek, M; Lomakin, Yu F; Lomakina, O V; Lund-Jensen, B; Mahout, G; Maio, A; Malyukov, S N; Mandelli, L; Mansoulié, B; Mapelli, Livio P; Marin, C P; Marroquin, F; Martin, L; Mazzanti, M; Mazzoni, E; Merritt, F S; Michel, B; Miller, R; Minashvili, I A; Miotto, A; Miralles, L; Mnatzakanian, E A; Monnier, E; Montarou, G; Mornacchi, Giuseppe; Muanza, G S; Nagy, E; Némécek, S; Nessi, Marzio; Nicoleau, S; Noppe, J M; Olivetto, C; Orteu, S; Padilla, C; Pallin, D; Pantea, D; Parrour, G; Pereira, A; Perini, L; Perlas, J A; Pétroff, P; Pilcher, J E; Pinfold, James L; Poggioli, Luc; Poirot, S; Polesello, G; Price, L; Protopopov, Yu; Proudfoot, J; Pukhov, O; Radeka, V; Rahm, David Charles; Reinmuth, G; Renardy, J F; Renzoni, G; Resconi, S; Richards, R; Riu, I; Romanov, V; Ronceux, B; Rumyantsev, V; Rusakovitch, N A; Sala, P R; Sanders, H; Sauvage, G; Savard, P; Savoy-Navarro, Aurore; Sawyer, L; Says, L P; Schaffer, A C; Scheel, C V; Schwemling, P; Schindling, J; Seguin-Moreau, N; Seixas, J M; Selldén, B; Seman, M; Semenov, A A; Senchyshyn, V G; Serin, L; Shchelchkov, A S; Shevtsov, V P; Shochet, M J; Sidorov, V; Simaitis, V J; Simion, S; Sissakian, A N; Solodkov, A A; Sonderegger, P; Soustruznik, K; Stanek, R; Starchenko, E A; Stephani, D; Stephens, R; Studenov, S; Suk, M; Surkov, A; Tang, F; Tardell, S; Tas, P; Teiger, J; Teubert, F; Thaler, J J; Tisserant, S; Tokár, S; Topilin, N D; Trka, Z; Turcot, A S; Turcotte, M; Valkár, S; Vartapetian, A H; Vazeille, F; Vichou, I; Vinogradov, V; Vorozhtsov, S B; Vuillemin, V; Wagner, D; White, Alan R; Wingerter-Seez, I; Yamdagni, N; Yarygin, G; Yosef, C; Zaitsev, A; Zdrazil, M; Zitoun, R; Zolnierowski, Y

    1996-01-01

    The first combined test of an electromagnetic liquid argon accordion calorimeter and a hadronic scintillating-tile calorimeter was carried out at the CERN SPS. These devices are prototypes of the barrel calorimeter of the future ATLAS experiment at the LHC. The energy resolution of pions in the energy range from 20 to 300~GeV at an incident angle $\\theta$ of about 11$^\\circ$ is well-described by the expression $\\sigma/E = ((46.5 \\pm 6.0)\\%/\\sqrt{E} +(1.2 \\pm 0.3)\\%) \\oplus (3.2 \\pm 0.4)~\\mbox{GeV}/E$. Shower profiles, shower leakage, and the angular resolution of hadronic showers were also studied.

  2. Results from a new combined test of an electromagnetic liquid argon calorimeter with a hadronic scintillating-tile calorimeter

    CERN Document Server

    Akhmadaliev, S Z; Amaral, P; Ambrosini, G; Amorim, A; Anderson, K; Andrieux, M L; Aubert, Bernard; Augé, E; Badaud, F; Baisin, L; Barreiro, F; Battistoni, G; Bazan, A; Bazizi, K; Bee, C P; Belorgey, J; Belymam, A; Benchekroun, D; Berglund, S R; Berset, J C; Blanchot, G; Bogush, A A; Bohm, C; Boldea, V; Bonivento, W; Borgeaud, P; Borisov, O N; Bosman, M; Bouhemaid, N; Breton, D; Brette, P; Bromberg, C; Budagov, Yu A; Burdin, S V; Calôba, L P; Camarena, F; Camin, D V; Canton, B; Caprini, M; Carvalho, J; Casado, M P; Cases, R; Castillo, M V; Cavalli, D; Cavalli-Sforza, M; Cavasinni, V; Chadelas, R; Chalifour, M; Chekhtman, A; Chevalley, J L; Chirikov-Zorin, I E; Chlachidze, G; Chollet, J C; Citterio, M; Cleland, W E; Clément, C; Cobal, M; Cogswell, F; Colas, Jacques; Collot, J; Cologna, S; Constantinescu, S; Costa, G; Costanzo, D; Coulon, J P; Crouau, M; Dargent, P; Daudon, F; David, M; Davidek, T; Dawson, J; De, K; Delagnes, E; de La Taille, C; Del Peso, J; Del Prete, T; de Saintignon, P; Di Girolamo, B; Dinkespiler, B; Dita, S; Djama, F; Dodd, J; Dolejsi, J; Dolezal, Z; Downing, R; Dugne, J J; Duval, P Y; Dzahini, D; Efthymiopoulos, I; Errede, D; Errede, S; Etienne, F; Evans, H; Eynard, G; Farida, F; Fassnacht, P; Fedyakin, N N; Fernández de Troconiz, J; Ferrari, A; Ferrer, A; Flaminio, Vincenzo; Fournier, D; Fumagalli, G; Gallas, E J; García, G; Gaspar, M; Gianotti, F; Gildemeister, O; Glagolev, V; Glebov, V Yu; Gómez, A; González, V; González de la Hoz, S; Gordeev, A; Gordon, H A; Grabskii, V; Graugès-Pous, E; Grenier, P; Hakopian, H H; Haney, M; Hébrard, C; Henriques, A; Henry-Coüannier, F; Hervás, L; Higón, E; Holmgren, S O; Hostachy, J Y; Hoummada, A; Huet, M; Huston, J; Imbault, D; Ivanyushenkov, Yu M; Jacquier, Y; Jézéquel, S; Johansson, E K; Jon-And, K; Jones, R; Juste, A; Kakurin, S; Karst, P; Karyukhin, A N; Khokhlov, Yu A; Khubua, J I; Klioukhine, V I; Kolachev, G M; Kolomoets, V; Kopikov, S V; Kostrikov, M E; Kovtun, V E; Kozlov, V; Krivkova, P; Kukhtin, V V; Kulagin, M; Kulchitskii, Yu A; Kuzmin, M V; Labarga, L; Laborie, G; Lacour, D; Lami, S; Lapin, V; Le Dortz, O; Lefebvre, M; Le Flour, T; Leitner, R; Leltchouk, M; Le Van-Suu, A; Li, J; Liapis, C; Linossier, O; Lissauer, D; Lobkowicz, F; Lokajícek, M; Lomakin, Yu F; Lomakina, O V; López-Amengual, J M; Lottin, J P; Lund-Jensen, B; Lundqvist, J M; Maio, A; Makowiecki, D S; Malyukov, S N; Mandelli, L; Mansoulié, B; Mapelli, Livio P; Marin, C P; Marrocchesi, P S; Marroquin, F; Martin, L; Martin, O; Martin, P; Maslennikov, A M; Massol, N; Mazzanti, M; Mazzoni, E; Merritt, F S; Michel, B; Miller, R; Minashvili, I A; Miralles, L; Mirea, A; Mnatzakanian, E A; Monnier, E; Montarou, G; Mornacchi, Giuseppe; Mosidze, M D; Moynot, M; Muanza, G S; Nagy, E; Nayman, P; Némécek, S; Nessi, Marzio; Nicod, D; Nicoleau, S; Niculescu, M; Noppe, J M; Onofre, A; Pallin, D; Pantea, D; Paoletti, R; Park, I C; Parrour, G; Parsons, J; Pascual, J I; Pereira, A; Perini, L; Perlas, J A; Perrodo, P; Petroff, P; Pilcher, J E; Pinhão, J; Plothow-Besch, Hartmute; Poggioli, Luc; Poirot, S; Price, L; Protopopov, Yu; Proudfoot, J; Pukhov, O; Puzo, P; Radeka, V; Rahm, David Charles; Reinmuth, G; Renardy, J F; Renzoni, G; Rescia, S; Resconi, S; Richards, R; Richer, J P; Riu, I; Roda, C; Roldán, J; Romance, J B; Romanov, V; Romero, P; Rusakovitch, N A; Sala, P R; Sanchis, E; Sanders, H; Santoni, C; Santos, J; Sauvage, D; Sauvage, G; Savoy-Navarro, Aurore; Sawyer, L; Says, L P; Schaffer, A C; Schwemling, P; Schwindling, J; Seguin-Moreau, N; Seidl, W; Seixas, J M; Selldén, B; Seman, M; Semenov, A A; Senchyshyn, V G; Serin, L; Shaldaev, E; Shchelchkov, A S; Shochet, M J; Sidorov, V; Silva, J; Simaitis, V J; Simion, S; Sissakian, A N; Soloviev, I V; Snopkov, R; Söderqvist, J; Solodkov, A A; Sonderegger, P; Soustruznik, K; Spanó, F; Spiwoks, R; Stanek, R; Starchenko, E A; Stavina, P; Stephens, R; Studenov, S; Suk, M; Surkov, A; Sykora, I; Taguet, J P; Takai, H; Tang, F; Tardell, S; Tas, P; Teiger, J; Teubert, F; Thaler, J J; Thion, J; Tikhonov, Yu A; Tisserand, V; Tisserant, S; Tokar, S; Topilin, N D; Trka, Z; Turcotte, M; Valkár, S; Varanda, M J; Vartapetian, A H; Vazeille, F; Vichou, I; Vincent, P; Vinogradov, V; Vorozhtsov, S B; Vuillemin, V; Walter, C; White, A; Wielers, M; Wingerter-Seez, I; Wolters, H; Yamdagni, N; Yarygin, G; Yosef, C; Zaitsev, A; Zitoun, R; Zolnierowski, Y

    2000-01-01

    A new combined test of an electromagnetic liquid argon accordion calorimeter and a hadronic scintillating-tile calorimeter was carried out at the CERN SPS. These devices are prototypes of the barrel calorimeter of the future ATLAS experiment at the LHC. The energy resolution of pions in the energy range from 10 to 300 GeV at an incident angle theta of about 12 degrees is well described by the expression sigma /E=((41.9+or-1.6)%/ square root E+(1.8+or-0.1)%)(+) (1.8+or-0.1)/E, where E is in GeV. The response to electrons and muons was evaluated. Shower profiles, shower leakage and the angular resolution of hadronic showers were also studied. Results are compared with those from the previous beam test. (22 refs).

  3. The implications of particle energy and acidic media on gross alpha and gross beta determination using liquid scintillation

    Energy Technology Data Exchange (ETDEWEB)

    Zapata-Garcia, D. [Laboratori de Radiologia Ambiental (LRA), Departament de Quimica Analitica, Universitat de Barcelona, Marti i Franques, 1-11 Planta 3, E-08028 Barcelona (Spain); Llaurado, M., E-mail: montse.llaurado@ub.edu [Laboratori de Radiologia Ambiental (LRA), Departament de Quimica Analitica, Universitat de Barcelona, Marti i Franques, 1-11 Planta 3, E-08028 Barcelona (Spain); Rauret, G. [Laboratori de Radiologia Ambiental (LRA), Departament de Quimica Analitica, Universitat de Barcelona, Marti i Franques, 1-11 Planta 3, E-08028 Barcelona (Spain)

    2012-04-15

    The interaction of humans with radioactivity present in the environment from natural and artificial sources necessitates an evaluation of its risk on human health. Gross alpha and gross beta activities can provide a rapid evaluation of the radioactive content of a sample and can be simultaneously determined by using liquid scintillation counters. However, calibration of the liquid scintillation counter is required and is affected by many factors, such as particle energy and the acidity of the media. This study investigates what effect the particle energy used for calibration has on misclassification and how to account for this misclassification in routine measurements. The variability in measurement produced by the final pH, as well as any acids used in sample treatment, was also studied. These results showed that the most commonly used acid for these types of analyses, HNO{sub 3}, produced a high amount of misclassifications at very low pH. The results improved when HCl was used to adjust the sample to low pH. - Highlights: Black-Right-Pointing-Pointer We study the effect of alpha and beta energies on PSA optimisation. Black-Right-Pointing-Pointer The optimum PSA shifts to higher values as the alpha energy increases. Beta energies do not affect it. Black-Right-Pointing-Pointer We study the effect of pH on the simultaneous determination of gross alpha/beta activities. Black-Right-Pointing-Pointer HNO{sub 3} produces a high amount of misclassification at very low pH. Black-Right-Pointing-Pointer The results improve when HCl is used to adjust the sample to low pH.

  4. The implications of particle energy and acidic media on gross alpha and gross beta determination using liquid scintillation

    International Nuclear Information System (INIS)

    Zapata-García, D.; Llauradó, M.; Rauret, G.

    2012-01-01

    The interaction of humans with radioactivity present in the environment from natural and artificial sources necessitates an evaluation of its risk on human health. Gross alpha and gross beta activities can provide a rapid evaluation of the radioactive content of a sample and can be simultaneously determined by using liquid scintillation counters. However, calibration of the liquid scintillation counter is required and is affected by many factors, such as particle energy and the acidity of the media. This study investigates what effect the particle energy used for calibration has on misclassification and how to account for this misclassification in routine measurements. The variability in measurement produced by the final pH, as well as any acids used in sample treatment, was also studied. These results showed that the most commonly used acid for these types of analyses, HNO 3 , produced a high amount of misclassifications at very low pH. The results improved when HCl was used to adjust the sample to low pH. - Highlights: ► We study the effect of alpha and beta energies on PSA optimisation. ► The optimum PSA shifts to higher values as the alpha energy increases. Beta energies do not affect it. ► We study the effect of pH on the simultaneous determination of gross alpha/beta activities. ► HNO 3 produces a high amount of misclassification at very low pH. ► The results improve when HCl is used to adjust the sample to low pH.

  5. Validated High Performance Liquid Chromatography Method for ...

    African Journals Online (AJOL)

    Purpose: To develop a simple, rapid and sensitive high performance liquid chromatography (HPLC) method for the determination of cefadroxil monohydrate in human plasma. Methods: Schimadzu HPLC with LC solution software was used with Waters Spherisorb, C18 (5 μm, 150mm × 4.5mm) column. The mobile phase ...

  6. Validated high performance liquid chromatographic (HPLC) method ...

    African Journals Online (AJOL)

    STORAGESEVER

    2010-02-22

    Feb 22, 2010 ... specific and accurate high performance liquid chromatographic method for determination of ZER in micro-volumes ... tional medicine as a cure for swelling, sores, loss of appetite and ... Receptor Activator for Nuclear Factor κ B Ligand .... The effect of ... be suitable for preclinical pharmacokinetic studies. The.

  7. Validated High Performance Liquid Chromatography Method for ...

    African Journals Online (AJOL)

    Purpose: To develop a simple, rapid and sensitive high performance liquid ... response, tailing factor and resolution of six replicate injections was < 3 %. ... Cefadroxil monohydrate, Human plasma, Pharmacokinetics Bioequivalence ... Drug-free plasma was obtained from the local .... Influence of probenicid on the renal.

  8. An improved method for 85Kr analysis by liquid scintillation counting and its application to atmospheric 85Kr determination

    International Nuclear Information System (INIS)

    Momoshima, Noriyuki; Inoue, Fumio; Sugihara, Shinji; Shimada, Jun; Taniguchi, Makoto

    2010-01-01

    Atmospheric 85 Kr concentration at Fukuoka, Japan was determined by an improved 85 Kr analytical method using liquid scintillation counting (LSC). An average value of 1.54 ± 0.05 Bq m -3 was observed in 2008, which is about two times that measured in 1981 at Fukuoka, indicating a 29 mBq y -1 rate of increase as an average for these 27 years. The analytical method developed involves collecting Kr from air using activated charcoal at liquid N 2 temperature and purifying it using He at dry ice temperature, followed by Kr separation by gas chromatography. An overall Kr recovery of 76.4 ± 8.1% was achieved when Kr was analyzed in 500-1000 l of air. The Kr isolated by gas chromatography was collected on silica gel in a quartz glass vial cooled to liquid N 2 temperature and the activity of 85 Kr was measured with a low-background LS counter. The detection limit of 85 Kr activity by the present analytical method is 0.0015 Bq at a 95% confidence level, including all propagation errors, which is equivalent with 85 Kr in 1.3 l of the present air under the analytical conditions of 72.1% counting efficiency, 0.1597 cps background count rate, and 76.4% Kr recovery.

  9. A scheme for recycling of used liquid scintillation counting cocktail for tritium analysis

    International Nuclear Information System (INIS)

    Gocher, A.K.; Tailor, S.P.; Tiwari, S.N.; Ravi, P.M.; Tripathi, R.M.

    2018-01-01

    Ultima Gold LLT TM is a ready to use scintillation cocktail used for estimation of tritium activity in various water sample collected from Rawatbhata Rajasthan Site environment up to 30 km radial distance. The present study explores the possibility of re-using the cocktail used in non detect (BDL) samples for counting of high active samples. Results of tritium standard counted with used cocktail (UC) was within ±10 % variation w.r.t fresh Ultima gold scintillation cocktail. Also results of high active samples prepared using 20 ml Used Cocktail (UC) and 1 ml sample (20 ml UC: 1ml aq. sample) were found in the range -7% to +11.1% w.r.t same sample prepared using fresh Ultima Gold. Used cocktail (UC) can be reused for tritium activity estimation of high active samples. Re-using of used cocktail will ultimately reduce the cocktail consumption, reduce the operational cost and reduce the quantity of waste cocktail disposal to the environment

  10. SCINFI, a program to calculate the standardization curve in liquid scintillation counting; SCINFI, un programa para calcular la curva de calibracion eficiencia-extincion en centelleo liquido

    Energy Technology Data Exchange (ETDEWEB)

    Grau Carles, A.; Grau Malonda, A.

    1984-07-01

    A code, SCINFI, was developed, written in BASIC, to compute the efficiency- quench standardization curve for any radionuclide. The program requires the standardization curve for 3H and the polynomial relations between counting efficiency and figure of merit for both 3H and the problem (e.g. 14{sup C}). The program is applied to the computation of the efficiency-quench standardization curve for 14{sup c}. Five different liquid scintillation spectrometers and two scintillator solutions have bean checked. The computation results are compared with the experimental values obtained with a set of 14{sup c} standardized samples. (Author)

  11. Preparatory on manganose salts of carboxilic acids labelled with 54Mn and comparison with 54MnCl2 in liquid scintillation counting

    International Nuclear Information System (INIS)

    Rodriguez, L.; Los Arcos, J.M.; Grau, A.

    1992-01-01

    Procedures for scintillation sample preparation of manganose dimethylbutirate, decanoate and palmitate, labelled with 54 Mn are described. Their quenching effect, spectral evolution and counting stability along several weeks are analysed in liquid scintillation measurements with Toluene, HlSafe II, PCS, Instagel, Dioxane-naphtalene and Toluene-alcohol. For comparison, inorganic 54 MnCl 2 samples are also studied, resulting in acceptable counting stability but showing greater quenching and signs of little spectral degradation against the organic samples. (author) 14 fig. 15 ref

  12. Preparation and calibration by liquid scintillation of a sample of Cl 36. Preparacion y calibracion por centelleo liquido de una muestra de Cl 36

    Energy Technology Data Exchange (ETDEWEB)

    Grau Malonda, A; Los Arcos, J M; Rodriguez Barquero, L; Suarez, C [Centro de Investigaciones Energeticas, Medioambientales y Tecnologicas, Madrid (Spain)

    1989-01-01

    A procedure to prepare a sample of Clorine 36, as Li{sup 36}Cl, able to be measured by liquid scintillation counting, is described. The sample is chemically stable, with no variation of the quenching parameter up to 4 mg of LiCl per 15 ml of scintillator, keeps constant the counting efficiency for concentration higher than 40 {mu}g of Li{sup 36}Cl in that volume, and shows no deterioration over a 3 weed period. The Li{sup 36}Cl solution has been standarized using the free parameter method with different volumes of toluene, PCS and Instagel, to an uncertainty of 0,3% (Author).

  13. Performance of 2000CA/LL and 2260XL liquid scintillation spectrometers for low-level tritium and carbon-14 analyses

    International Nuclear Information System (INIS)

    Rozanski, K.; Stichler, W.; Schwarz, P.

    1991-01-01

    The performance of two commercially available liquid scintillation spectrometers for low-level counting of 3 H and 14 C has been investigated. Two models of new technology Tri-Carb spectrometers from the Packard Instrument Company were tested: the 2000CA/LL and 2260XL. The measurements revealed a superior 3 H performance of the 2000CA/LL equipment owing to its substantially higher counting efficiency. Results for 14 C are less conclusive and depend on the configuration of the counting parameters selected. A comparison of three commercially available scintillation cocktails for tritium assay in water samples revealed a superior performance for PicoFluor LLT. (Author)

  14. Liquid scintillation counting efficiency in three photomultiplier systems. Pure electron capture; Eficiencia de recuento por centelleo liquido en sistemas con tres fotomultiplicadores. Captura electronica pura

    Energy Technology Data Exchange (ETDEWEB)

    Los Arcos, J M; Grau Carles, A; Grau Malonda, A

    1990-07-01

    The tables of counting efficiency as a function of the figure of merit for a liquid scintillation counting system working with three phototubes are presented. The evaluation has been carried out for a Toluene-based scintillator with 5, 10 and 15 ml column, and 19 different radionuclides decaying by pure electron capture: 37Ar 41Ca, 49V, 53 Mn, 55Fe, 59Ni, 68Ge 7iGe, 82Sr, 97Tc, 118Te, 131CS, 137La, 140Ca, 157Tb, 165Er, 193Pt, 194Hg, 205Pb. (Author) 22 refs.

  15. Liquid scintillation counting of calcium-45 in plant and soil material

    International Nuclear Information System (INIS)

    Waller, S.S.; Dodd, J.D.

    1977-01-01

    The recovery efficiencies of 45 Ca, for plant material using dry ashing with HCL as the extractant, and for soils using column extraction with MgCl 2 as the extractant, have been determined. The extraction and detection procedures, using available scintillation solvent systems, are given and show a combination of a high counting efficiency with high recovery efficiencies. The extraction procedures are simple, involving minimal operator time, and allow simultaneous 45 Ca determination in both plant and soil material. Both extraction procedures exhibit good reproducibility over a wide range of specific activities while being relatively insensitive to quenching and carrier calcium normally encountered in plant and soil material. These procedures are particularly useful in ecological studies requiring the examination of a large number of plant and/or soil samples over a wide range of radioactive concentrations. (U.K.)

  16. Scintillators and other particle optical detectors

    International Nuclear Information System (INIS)

    Chipaux, R.

    2011-01-01

    The author reports and comments his researcher career in the field of particle optical detectors. He addresses the cases of organic scintillators (scintillating fibers, liquid scintillators), inorganic scintillators (crystals for electromagnetic calorimetry, crystals for solar neutrino spectroscopy), and Cherenkov Effect detectors. He also reports his works on Cd Te detectors and their modelling

  17. Study of the factors affecting the performance of microextraction by packed sorbent (MEPS) using liquid scintillation counter and liquid chromatography-tandem mass spectrometry

    International Nuclear Information System (INIS)

    Altun, Zeki; Abdel-Rehim, Mohamed

    2008-01-01

    Microextraction by packed sorbent (MEPS) is a new technique for sample preparation that can be connected on-line with LC or GC. In MEPS, approximately 1-2 mg of the solid packing material is inserted into a syringe (100-250 μL) as a plug. Sample preparation takes place on the packed bed. The bed can be packed or coated to provide selective and suitable sampling conditions. The new method is very promising for extraction of drugs and metabolites from biological samples. In this paper, some factors affecting the performance of MEPS such as recovery, carry-over, leakage, washing volume and elution volume were studied using C18 and hydroxylated polystyrene-divinylbenzene copolymer (ENV+) as sorbents. Radioactively labelled bupivacaine in plasma samples was used as test analyte. For the extraction of this drug, using methanol/water 95:5 (v/v) (0.25% ammonium hydroxide) was used as elution solvent. The analyte response increased with increasing the elution volume and it was linear upp up to 100 μL utilizing liquid scintillation counter. Further, for concentrating the sample, we found that MEPS may be used such that the sample can be drawn through the needle, up and down, several times. The analyte leakage increases as the volume washing increases, though higher washing volumes may also result in cleaner extracts. To eliminate analyte carry-over, the sorbents were washed first with 3 x 250 μL elution solution and then with 3 x 250 μL washing solution. In addition, the reproducibility measurements show relatively good relative standard deviation (RSD) % values concerning analyte recovery and analyte leakage. The present study provides an understanding of basic aspects when optimizing methods for MEPS. In this study, MEPS was used off-line with liquid scintillation counter and on-line with LC-MS/MS

  18. Study of the factors affecting the performance of microextraction by packed sorbent (MEPS) using liquid scintillation counter and liquid chromatography-tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Altun, Zeki [Karlstad University, Faculty of Technology and Science, SE-651 88 Karlstad (Sweden); Abdel-Rehim, Mohamed [Karlstad University, Faculty of Technology and Science, SE-651 88 Karlstad (Sweden); Clinical Pharmacology and DMPK, AstraZeneca R and D Soedertaelje, SE-151 85 Soedertaelje (Sweden)], E-mail: Mohamed.Abdel-Rehim@Astrazeneca.com

    2008-12-23

    Microextraction by packed sorbent (MEPS) is a new technique for sample preparation that can be connected on-line with LC or GC. In MEPS, approximately 1-2 mg of the solid packing material is inserted into a syringe (100-250 {mu}L) as a plug. Sample preparation takes place on the packed bed. The bed can be packed or coated to provide selective and suitable sampling conditions. The new method is very promising for extraction of drugs and metabolites from biological samples. In this paper, some factors affecting the performance of MEPS such as recovery, carry-over, leakage, washing volume and elution volume were studied using C18 and hydroxylated polystyrene-divinylbenzene copolymer (ENV+) as sorbents. Radioactively labelled bupivacaine in plasma samples was used as test analyte. For the extraction of this drug, using methanol/water 95:5 (v/v) (0.25% ammonium hydroxide) was used as elution solvent. The analyte response increased with increasing the elution volume and it was linear upp up to 100 {mu}L utilizing liquid scintillation counter. Further, for concentrating the sample, we found that MEPS may be used such that the sample can be drawn through the needle, up and down, several times. The analyte leakage increases as the volume washing increases, though higher washing volumes may also result in cleaner extracts. To eliminate analyte carry-over, the sorbents were washed first with 3 x 250 {mu}L elution solution and then with 3 x 250 {mu}L washing solution. In addition, the reproducibility measurements show relatively good relative standard deviation (RSD) % values concerning analyte recovery and analyte leakage. The present study provides an understanding of basic aspects when optimizing methods for MEPS. In this study, MEPS was used off-line with liquid scintillation counter and on-line with LC-MS/MS.

  19. Comparison of calculated spectra for the interaction of photons in a liquid scintillator. Example of Mn-54 835 keV emission

    CSIR Research Space (South Africa)

    Cassette, P

    2006-10-01

    Full Text Available and the associated probability of absorption. The validity of the method is thus dependent on the correct calculation of the energy transferred to the scintillator. In order to compare the calculation results obtained using various calculation tools, and to provide...

  20. Radiostrontium accumulation in animal bones: development of a radiochemical method by ultra low-level liquid scintillation counting for its quantification.

    Science.gov (United States)

    Iammarino, Marco; Dell'Oro, Daniela; Bortone, Nicola; Mangiacotti, Michele; Chiaravalle, Antonio Eugenio

    2018-03-31

    Strontium-90 (90Sr) is a fission product, resulting from the use of uranium and plutonium in nuclear reactors and weapons. Consequently, it may be found in the environment as a consequence of nuclear fallouts, nuclear weapon testing, and not correct waste management. When present in the environment, strontium-90 may be taken into animal body by drinking water, eating food, or breathing air. The primary health effects are bone tumors and tumors of the blood-cell forming organs, due to beta particles emitted by both 90Sr and yttrium-90 (90Y). Moreover, another health concern is represented by inhibition of calcification and bone deformities in animals. Actually, radiometric methods for the determination of 90Sr in animal bones are lacking. This article describers a radiochemical method for the determination of 90Sr in animal bones, by ultra low-level liquid scintillation counting. The method precision and trueness have been demonstrated through validation tests (CV% = 12.4%; mean recovery = 98.4%). Detection limit and decision threshold corresponding to 8 and 3 mBecquerel (Bq) kg-1, respectively, represent another strong point of this analytical procedure. This new radiochemical method permits the selective extraction of 90Sr, without interferences, and it is suitable for radiocontamination surveillance programs, and it is also an improvement with respect to food safety controls.

  1. Scintillation efficiency and X-ray imaging with the RE-Doped LuAG thin films grown by liquid phase epitaxy

    International Nuclear Information System (INIS)

    Tous, Jan; Blazek, Karel; Kucera, Miroslav; Nikl, Martin; Mares, Jiri A.

    2012-01-01

    Very thin scintillator imaging plates have recently become of great interest. In high resolution X-ray radiography, very thin scintillator layers of about 5–20 μm are used to achieve 2D-spatial resolutions below 1 μm. Thin screens can be prepared by mechanical polishing from single crystals or by epitaxial growth on single-crystal substrates using the Liquid Phase Epitaxy technique (LPE). Other types of screens (e.g. deposited powder) do no reach required spatial resolutions. This work compares LPE-grown YAG and LuAG scintillator films doped with different rare earth ions (Cerium, Terbium and Europium). Two different fluxes were used in the LPE growth procedure. These LPE films are compared to YAG:Ce and LuAG:Ce screens made from bulk single crystals. Relative light yield was detected by a highly sensitive CCD camera. Scintillator screens were excited by a micro-focus X-ray source and the generated light was gathered by the CCD camera’s optical system. Scintillator 2D-homogeneity is examined in an X-ray imaging setup also using the CCD camera.

  2. Measurement of gross alpha, gross beta, radon and radium activity concentrations in aqueous samples using liquid scintillation technique

    International Nuclear Information System (INIS)

    Zaini Hamzah; Ahmad Saat; Masitah Alias; Siti Afiqah Abdul Rahman; Mohamed Kasim; Abdul Kadir Ishak

    2011-01-01

    Recently, Malaysia has taken a positive step toward providing a better water quality by introducing more water quality parameters into its Water Quality Standard. With regard to the natural radionuclides that may present in the water, 3 parameters were introduced that is gross alpha, gross beta and radium which need to be measured and cannot exceed 0.1, 1.0 and 1.0 Bq/ L respectively. This study was conducted to develop a more practical method in measuring these parameters in aqueous environmental samples. Besides having a lot of former tin mining areas, some part of Malaysia is located on the granitic rock which also contributes to a certain extent the amount of natural radionuclides such as uranium and thorium. For all we know these two radionuclides are the origin of other radionuclides being produced from their decay series. The State of Kelantan was chosen as the study area, where the water samples were collected from various part of the Kelantan River. 25 liters of samples were collected, acidify to pH 2 and filtered before the analysis. Measurement of these parameters was done using liquid scintillation counter (LSC). The LSC was set up to the optimum discriminator level and counting was done using alpha-beta mode. The results show that gross alpha and beta can be measured using scintillation cocktail and radium and radon using extraction method. The results for gross alpha, gross beta, 222 Ra and 226 Ra are 0.39-6.42, 0.66-16.18, 0.40-4.65 and 0.05-0.56 Bq/ L. MDA for gross alpha, gross beta and radium is 0.03, 0.08 and 0.00035 Bq/ L respectively. (Author)

  3. Comparison of analysis techniques by liquid scintillation and Cerenkov Effect for {sup 40}K quantification in aqueous samples; Comparacion de las tecnicas de analisis por centelleo liquido y efecto Cerenkov para la cuantificacion {sup 40}K en muestras acuosas

    Energy Technology Data Exchange (ETDEWEB)

    Miranda C, L.; Davila R, J. I.; Lopez del R, H.; Mireles G, F., E-mail: lilimica20@hotmail.com [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas, Zac. (Mexico)

    2015-09-15

    In this work the counting by liquid scintillation and Cerenkov Effect to quantify {sup 40}K in aqueous samples was used. The performance of both techniques was studied by comparing the response of three commercial liquid scintillation OptiPhase HiSafe 3, Ultima Gold Ab and OptiPhase TriSafe, the vial type and presentation conditions of the sample for counting. In liquid scintillation, the ability to form homogeneous mixtures depended on the ionic strength of the aqueous solutions. The scintillator OptiPhase HiSafe 3 showed a greater charge capacity for solutions with high ionic strength (<3.4), while the scintillator OptiSafe TriSafe no form homogeneous mixtures for solutions of ionic strength higher than 0.3. Counting efficiencies for different proportions of sample and scintillator near 100% for the scintillators OptiSafe HiSafe 3 and Ultima Gold Ab were obtained. In the counting by Cerenkov Effect, the efficiency and sensitivity depended of the vial type; polyethylene vials were more suitable for counting that the glass vials. The sample volume had not significant effect on counting efficiency, obtaining an average value of 44.8% for polyethylene vials and 37.3% for glass vials. Therefore, the liquid scintillation was more efficient and sensitive for the measurement of {sup 40}K in aqueous solutions. (Author)

  4. Monitoring gross alpha and beta activity in liquids by using ZnS(Ag) scintillation detectors

    Energy Technology Data Exchange (ETDEWEB)

    Stevanato, L.; Cester, D.; Filippi, D.; Lunardon, M.; Mistura, G.; Moretto, S.; Viesti, G. [Department of Physics and Astronomy ' Galileo Galilei' , University of Padova, (Italy); Badocco, D.; Pastore, P.; Romanini, F. [Department of Chemical Sciences, University of Padova, (Italy)

    2015-07-01

    In this work the possibility of monitoring gross alpha and beta activity in liquids using EJ-444 was investigated. Specific tests were carried out to determine the change of the detector properties in water tests. Possible protecting coating is also proposed and tested. Alpha/beta real-time monitoring in liquids is a goal of the EU project TAWARA{sub R}TM. (authors)

  5. Light output response of EJ-309 liquid organic scintillator to 2.86-3.95 MeV carbon recoil ions due to neutron elastic and inelastic scatter

    Science.gov (United States)

    Norsworthy, Mark A.; Ruch, Marc L.; Hamel, Michael C.; Clarke, Shaun D.; Hausladen, Paul A.; Pozzi, Sara A.

    2018-03-01

    We present the first measurements of energy-dependent light output from carbon recoils in the liquid organic scintillator EJ-309. For this measurement, neutrons were produced by an associated particle deuterium-tritium generator and scattered by a volume of EJ-309 scintillator into stop detectors positioned at four fixed angles. Carbon recoils in the scintillator were isolated using triple coincidence among the associated particle detector, scatter detector, and stop detectors. The kinematics of elastic and inelastic scatter allowed data collection at eight specific carbon recoil energies between 2.86 and 3.95 MeV. We found the light output caused by carbon recoils in this energy range to be approximately 1.14% of that caused by electrons of the same energy, which is comparable to the values reported for other liquid organic scintillators. A comparison of the number of scattered neutrons at each angle to a Monte Carlo N-Particle eXtended simulation indicates that the ENDF/B-VII.1 evaluation of differential cross sections for 14.1 MeV neutrons on carbon has discrepancies with the experiment as large as 55%, whereas those reported in the JENDL-4.0u evaluation agree with experiment.

  6. Advances in the sample preparation and the detector for a combined solvent extraction-liquid scintillation method of low-level plutonium measurement

    International Nuclear Information System (INIS)

    Perdue, P.T.; Christian, D.J.; Thorngate, J.H.; McDowell, W.J.; Case, G.N.

    1976-07-01

    A combined solvent extraction-liquid scintillation technique, developed at Oak Ridge National Laboratory (ORNL), has many possible applications to the determination of low levels of plutonium and other alpha-emitting nuclides. Using these procedures, plutonium can be extracted from biological or environmental samples and introduced directly into a liquid scintillator. Quenching of the scintillator is thus minimized so that spectroscopic techniques may be employed. Existing chemical procedures and counting equipment were reviewed and improved. Purification of the di(2-ethylhexyl)phosphoric acid (used as the actinide extractant) was found necessary. Destruction of organic material in the sample and control of the valence state of plutonium were found to be major sources of irreproducibility. Methods were developed to allow samples separated with commonly used ion exchange techniques to be extracted into the scintillator. Comparisons were made of a wide variety of the components and parameters of the detector system to find the best combination of pulse-height resolution and pulse-shape discrimination. When a single phototube was used, optimum performance was obtained using a hemispherical reflector-sample holder viewed sideways by an RCA 8575 photomultiplier tube used in conjunction with a special integrating preamplifier and a good quality linear amplifier that used delay lines to shape the pulses

  7. Resistance of an enamel-bonding agent to saliva and acid exposure in vitro assessed by liquid scintillation.

    Science.gov (United States)

    Schmidlin, P R; Göhring, T N; Sener, B; Lutz, F

    2002-06-01

    To determine the leakage and resistance of a bonding agent and a light-curing fine hybrid composite when exposed to saliva or lactic acid (pH 4) in vitro. Twenty discs in each of four groups of selected irradiated bovine lower central incisors were treated with one of three sealing options: an enamel bond (Heliobond, Vivadent, Schaan, Liechenstein) in a single-step application; Heliobond in a two-step application; and Tetric Flow (Vivadent) as the negative control. One group served as the positive control and remained unsealed. Loss of apatite was determined using the radiochemical method of liquid scintillation. The Cherenkov radiation was assessed in order to evaluate the acid resistance and leakage of smooth surface enamel bonding after exposure to saliva and lactic acid. In addition, replicas were made for SEM analysis of micromorphologic surface changes. A mean loss of 416.5 g (s.d. 57.0) apatite was observed over the unsealed sites following 14 days of exposure to lactic acid. The application of Heliobond in a one- and two-step application still revealed a remarkable degree of leakage, and substance losses of 196.5 g (s.d. 38.9) and 161.8 g (s.d. 39.7), but a protective potential was evident. In saliva, untreated, as well as sealed teeth, showed a modest leakage that was less than 20 g. When Tetric Flow was used (negative control) leakage was reduced to a minimum of 2.4 g (s.d. 1.0) in saliva and 12.8 g (s.d. 19.6) in lactic acid. These results were confirmed by SEM analysis. The method of liquid scintillation was revealed to be of considerable value in evaluating leakage and acid resistance of potential smooth enamel sealing options. Sealing with an unfilled resin still demonstrated remarkable levels of acid dissolution, although a protection tendency could be observed. This leads to the conclusion that there is a need for further investigation to establish more acid-resistant enamel sealing agents.

  8. Active background suppression with the liquid argon scintillation veto of GERDA Phase II

    Science.gov (United States)

    Agostini, M.; Allardt, M.; Bakalyarov, A. M.; Balata, M.; Barabanov, I.; Baudis, L.; Bauer, C.; Bellotti, E.; Belogurov, S.; Belyaev, S. T.; Benato, G.; Bettini, A.; Bezrukov, L.; Bode, T.; Borowicz, D.; Brudanin, V.; Brugnera, R.; Caldwell, A.; Cattadori, C.; Chernogorov, A.; D'Andrea, V.; Demidova, E. V.; Di Marco, N.; Domula, A.; Doroshkevich, E.; Egorov, V.; Falkenstein, R.; Frodyma, N.; Gangapshev, A.; Garfagnini, A.; Gooch, C.; Grabmayr, P.; Gurentsov, V.; Gusev, K.; Hakenmüller, J.; Hegai, A.; Heisel, M.; Hemmer, S.; Hofmann, W.; Hult, M.; Inzhechik, L. V.; Janicskó Csáthy, J.; Jochum, J.; Junker, M.; Kazalov, V.; Kihm, T.; Kirpichnikov, I. V.; Kirsch, A.; Kish, A.; Klimenko, A.; Kneißl, R.; Knöpfle, K. T.; Kochetov, O.; Kornoukhov, V. N.; Kuzminov, V. V.; Laubenstein, M.; Lazzaro, A.; Lebedev, V. I.; Lehnert, B.; Liao, H. Y.; Lindner, M.; Lippi, I.; Lubashevskiy, A.; Lubsandorzhiev, B.; Lutter, G.; Macolino, C.; Majorovits, B.; Maneschg, W.; Medinaceli, E.; Miloradovic, M.; Mingazheva, R.; Misiaszek, M.; Moseev, P.; Nemchenok, I.; Palioselitis, D.; Panas, K.; Pandola, L.; Pelczar, K.; Pullia, A.; Riboldi, S.; Rumyantseva, N.; Sada, C.; Salamida, F.; Salathe, M.; Schmitt, C.; Schneider, B.; Schönert, S.; Schreiner, J.; Schulz, O.; Schütz, A.-K.; Schwingenheuer, B.; Selivanenko, O.; Shevzik, E.; Shirchenko, M.; Simgen, H.; Smolnikov, A.; Stanco, L.; Vanhoefer, L.; Vasenko, A. A.; Veresnikova, A.; von Sturm, K.; Wagner, V.; Wegmann, A.; Wester, T.; Wiesinger, C.; Wojcik, M.; Yanovich, E.; Zhitnikov, I.; Zhukov, S. V.; Zinatulina, D.; Zuber, K.; Zuzel, G.

    2017-09-01

    The observation of neutrinoless double beta decay would allow to shed light onto the particle nature of neutrinos. Gerda is aiming to perform a background-free search for this process using high purity germanium detectors enriched in 76Ge operated in liquid argon. This goal relies on the application of active background suppression techniques. A low background light instrumentation has been installed for Phase II to detect events with coincident energy deposition in the nearby liquid argon. The intended background index of ˜10-3 cts/(keV·ky·yr) has been confirmed.

  9. Comparison of triple to double coincidence ratio and Quench Parameter External methods for the determination of 3H efficiency by liquid scintillation counting

    International Nuclear Information System (INIS)

    Nisti, M.B.; Saueia, C.H.R.; Mazzilli, B.P.

    2013-01-01

    The aim of this study is to determine the tritium efficiency by liquid scintillation counting using two methodologies, Quench Parameter External (QPE) and Triple to Double Coincidence Ratio (TDCR), and to compare the results. The equipment used was the HIDEX model 300-SL Liquid Scintillation Counter, composed of three photomultipliers coupled with coincidence pulses, discrimination level and Mikro Win 2000 software. The efficiency varied from 0.028 to 0.706 cps dps -1 for QPE and from 0.061 to 0.703 cps dps -1 for TDCR. Different efficiencies were obtained using both methods, in the range from 459 to 572 quenching, above this range the efficiencies were similar. The verification of the efficiencies was performed by participating in the Intercomparison National Program (PNI). (author)

  10. Improved method for the determination of the cortisol production rate using high-performance liquid chromatography and liquid scintillation counting

    NARCIS (Netherlands)

    van Ingen, H. E.; Endert, E.

    1988-01-01

    Two new methods for the determination of the cortisol production rate using reversed-phase high-performance liquid chromatography are described. One uses ultraviolet detection at 205 nm, the other on-line post-column derivatization with benzamidine, followed by fluorimetric detection. The specific

  11. Microfluidic Scintillation Detectors for High Energy Physics

    CERN Document Server

    Maoddi, Pietro; Mapelli, Alessandro

    This thesis deals with the development and study of microfluidic scintillation detectors, a technology of recent introduction for the detection of high energy particles. Most of the interest for such devices comes from the use of a liquid scintillator, which entails the possibility of changing the active material in the detector, leading to increased radiation resistance. A first part of the thesis focuses on the work performed in terms of design and modelling studies of novel prototype devices, hinting to new possibilities and applications. In this framework, the simulations performed to validate selected designs and the main technological choices made in view of their fabrication are addressed. The second part of this thesis deals with the microfabrication of several prototype devices. Two different materials were studied for the manufacturing of microfluidic scintillation detectors, namely the SU-8 photosensitive epoxy and monocrystalline silicon. For what concerns the former, an original fabrication appro...

  12. Average energy expended per ion pair, exciton enhanced ionization (Jesse effect), electron drift velocity, average electron energy and scintillation in rare gas liquids

    International Nuclear Information System (INIS)

    Doke, T.; Hitachi, A.; Hoshi, Y.; Masuda, K.; Hamada, T.

    1977-01-01

    Precise measurements of W-values, the average energy expended per electron-hole pair in liquid Ar and Xe, were made by the electron-pulse method, and that in liquid Kr by the steady conduction current method. The results showed that the W-values were clearly smaller than those in gaseous Ar, Xe and Kr as predicted by Doke. The results can be explained by the conduction bands which exist in these rare gas liquids as well as in the solid state. The enhanced ionization yield was observed for Xe-doped liquid Ar, and it was attributed to the ionizing excitation transfer process from Ar excitons to doped Xe. This is very similar to the Jesse effect in the gas phase. The saturated value of the enhanced ionization was in good agreement with the theoretical value, and it provides strong evidence for the existence of the exciton states in liquid Ar. Fano factors in liquid Ar, Kr, Xe and Xe-doped liquid Ar have been estimated from the Fano Formula, and they were smaller than those in the gas phase. The drift velocity of electrons in liquid Ar, liquid Ar-gas mixtures and liquid Xe have been measured with gridded ionization chambers. The average electron energy in liquid Ar has been measured. The electron-induced scintillations of liquid Xe and Ar have been studied. (Kato, T.)

  13. CNO and pep neutrino spectroscopy in Borexino: Measurement of the deep underground production of cosmogenic 11C in organic liquid scintillator

    OpenAIRE

    Borexino Collaboration

    2006-01-01

    Borexino is an experiment for low energy neutrino spectroscopy at the Gran Sasso underground laboratories. It is designed to measure the mono-energetic $^7$Be solar neutrino flux in real time, via neutrino-electron elastic scattering in ultra-pure organic liquid scintillator. Borexino has the potential to also detect neutrinos from the \\emph{pep} fusion process and the CNO cycle. For this measurement to be possible, radioactive contamination in the detector must be kept extremely low. Once su...

  14. Standardization of 137mCs+137mBa by Liquid Scintillation; Calibracion de 137Cs+137mBa por Centelleo Liquido

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez, L.; Los Arcos, J.M.; Grau, A.

    1995-07-01

    A procedure for the preparation of a stable, homogeneous solution of 137Cs+''137mBa, for use in liquid scintillation measurements, is described. Its count rate stability and spectral time evolution has been followed for several weeks. The solution has been standardised by the CIEMAT/NIST method in both Ultima-Gold and Insta-Gel, to a combined uncertainty lower than 0,51 % (k=l). (Author) 5 refs.

  15. Use of K360Co(CN)6 and 114mInEDTA tracers determined by liquid scintillators method in hydrogeologic studies

    International Nuclear Information System (INIS)

    Lebecka, J.; Tomza, I.; Trzebicka, B.; Soltyk, W.

    1986-01-01

    The sensitive methods of K 3 60 Co(CN) 6 and 114m InEDTA tracers detection using the measurements by liquid scintillators method were elaborated to broaden the range of their use. The radiochemical separation of radioisotopes from investigated water samples and the measurement of their activity as well as double labelled samples are described. The practical uses of tracers are given. (A.S.)

  16. Activity measurements of radioactive solutions by liquid scintillation counting and pressurized ionization chambers and Monte Carlo simulations of source-detector systems for metrology

    International Nuclear Information System (INIS)

    Amiot, Marie-Noelle

    2013-01-01

    The research works 'Activity measurements of radioactive solutions by liquid scintillation and pressurized ionization chambers and Monte Carlo simulations of source-detector systems' was presented for the graduation: 'Habilitation a diriger des recherches'. The common thread of both themes liquid scintillation counting and pressurized ionization chambers lies in the improvement of the techniques of radionuclide activity measurement. Metrology of ionization radiation intervenes in numerous domains, in the research, in the industry including the environment and the health, which are subjects of constant concern for the world population these last years. In this big variety of applications answers a large number of radionuclides of diverse disintegration scheme and under varied physical forms. The presented works realized within the National Laboratory Henri Becquerel have for objective to assure detector calibration traceability and to improve the methods of activity measurements within the framework of research projects and development. The improvement of the primary and secondary activity measurement methods consists in perfecting the accuracy of the measurements in particular by a better knowledge of the parameters influencing the detector yield. The works of development dealing with liquid scintillation counting concern mainly the study of the response of liquid scintillators to low energy electrons as well as their linear absorption coefficients using synchrotron radiation. The research works on pressurized ionization chambers consist of the study of their response to photons and electrons by experimental measurements compared to the simulation of the source-detector system using Monte Carlo codes. Besides, the design of a new type of ionization chamber with variable pressure is presented. This new project was developed to guarantee the precision of the amount of activity injected into the patient within the framework of diagnosis examination

  17. A high-resolution detector based on liquid-core scintillating fibres with readout via an electron-bombarded charge-coupled device

    International Nuclear Information System (INIS)

    Cianfarani, C.; Duane, A.; Fabre, J.P.; Frenkel, A.; Golovkin, S.V.; Gorin, A.M.; Harrison, K.; Kozarenko, E.N.; Kushnirenko, A.E.; Ladygin, E.A.; Martellotti, G.; Medvedkov, A.M.; Nass, P.A.; Obudovski, V.P.; Penso, G.; Petukhov, Yu.P.; Siegmund, W.P.; Tyukov, V.E.; Vasilchenko, V.G.

    1994-01-01

    This paper is a presentation of results from tests in a 5 GeV/c hadron beam of detectors based on liquid-core scintillating fibres, each fibre consisting of a glass capillary filled with organic liquid scintillator. Fibre readout was performed via an Electron-Bombarded Charge-Coupled Device (EBCCD) image tube, a novel instrument that combines the functions of a high-gain, gated image intensifier and a Charge-Coupled Device. Using 1-methylnaphthalene doped with 3 g/l of R45 as liquid scintillator, the attenuation lengths obtained for light propagation over distances greater than 16 cm were 1.5 m in fibres of 20 μm core and 1.0 m in fibres of 16 μm core. For particles that crossed the fibres of 20 μm core at distances of ∼1.8 cm and ∼95 cm from the fibres' readout ends, the recorded hit densities were 5.3 mm -1 and 2.5 mm -1 respectively. Using 1-methylnaphthalene doped with 3.6 g/l of R39 as liquid scintillator and fibres of 75 μm core, the hit density obtained for particles that crossed the fibres at a distance of ∼1.8 cm from their readout ends was 8.5 mm -1 . With a specially designed bundle of tapered fibres, having core diameters that smoothly increase from 16 μm to 75 μm, a spatial precision of 6 μm was measured. (orig.)

  18. Development and Validation of a Liquid Chromatographic Method ...

    African Journals Online (AJOL)

    A liquid chromatographic method for the simultaneous determination of six human immunodeficiency virus (HIV) protease inhibitors, indinavir, saquinavir, ritonavir, amprenavir, nelfinavir and lopinavir, was developed and validated. Optimal separation was achieved on a PLRP-S 100 Å, 250 x 4.6 mm I.D. column maintained ...

  19. Determination of radiostrontium released from Fukushima Daiichi Nuclear Power Plant through extraction chromatography and liquid scintillation counting

    International Nuclear Information System (INIS)

    Maekawa, Akihiro; Momoshima, Noriyuki; Sugihara, Shinji; Tamari, Toshiya

    2013-01-01

    Two soil samples were collected on April 18-20, 2011 at Namie town and Tomioka town, which are located 26 km northwest and 11 km south of the Fukushima Daiichi Nuclear Power Plant, respectively. A 0-1 cm soil layer was used for analysis to determine the presence of radiostrontium. The soil was ashed, acid-digested, and strontium was separated from interference with use of an extraction chromatography resin (Sr resin, Eichrom Technologies). The isolation and purification of strontium from matrix components can be completed in 12 h. After 2 weeks for ingrowth of "9"0Y, measurements of a beta-ray of "9"0Y and "8"9"+"9"0Sr were conducted with a low-background liquid-scintillation counter for 1200 min. The concentration of "9"0Sr was determined to be 57.4 ± 1.0 and 10.1 ± 0.4 Bq kg"-"1 for Namie town and Tomioka town, respectively. "8"9Sr was not detected in either sample. The extraction chromatography method was successfully applied to determine the level of radiostrontium in the contaminated soil. When 2 g of soil is used, the detection limit of "9"0Sr is evaluated to be 2.7 Bq kg"-"1 under a chemical yield of strontium of 70%. (author)

  20. Study of the radioactivity of drinking water in the city of Antsirabe using the method of liquid scintillation counting

    International Nuclear Information System (INIS)

    RAKOTOMANGA, H.

    2003-01-01

    The objective of this work is to determine the radioactivity by liquid scintillation counting (LSC) and to study the distribution of radionuclides in drinking water from the Antsirabe region. Optiphase Hisafe 3TM is used to measure gross alpha-beta radioactivity. Radium, radon and the excess of short half-life radionuclides are obtained from MaxilightTM cocktail. Results of measurement of drinking water samples show that : gross alpha-beta activities are between (120±27) Bq.l -1 and (426±47) Bq.l -1 , the radium activities are from (14±2)Bq.l -1 to (78±5) Bq.l -1 , radon activities are from (0.6±0.2)Bq.l -1 to (60±6) Bq.l -1 , short half-life radionuclides activities are between 25±8 Bq.l -1 and 270±27 Bq.l -1 .Annual dose exposure from ingestion of radium-226 is between (2.09 ± 0.32)mSv and (11.03 ± 0.73)mSv. These values are close to the Malagasy standard (5 mSv). The results show that drinking waters from the Antsirabe region contain natural radionuclides. Dose exposure increases if the water is directly ingested after collection. [fr

  1. {sup 226}Ra, {sup 228}Ra and {sup 210}Pb determination in surface water and groundwater by liquid scintillation counting

    Energy Technology Data Exchange (ETDEWEB)

    Faria, Ligia S.; Moreira, Rubens M., E-mail: ligsfaria@gmail.com, E-mail: rubens@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2015-07-01

    The municipalities of Brumadinho and Nova Lima are located in the metropolitan region of Belo Horizonte city, in the State of Minas Gerais. These two sites are important due to being located inside an Environmental Protection Area inserted in the Iron Quadrangle. In addition to the mineral wealth, the region has geological features that include quartz conglomerates associated with uranium and a significant groundwater potential exhibiting quite peculiar and complex hydrogeological features, such as the quartzite aquifer itself. Nuclear techniques applied to hydrology, such as Liquid Scintillation Counting technique (LSC), make possible the evaluation of natural radioactivity in surface water and groundwater. The objectives of this study were the determination of the activities of the long half-life radionuclides of the uranium and thorium series, such as {sup 226}Ra, {sup 228}Ra and {sup 210}Pb, and provide an effective methodology to define if the direct consumption of these waters can cause risk to health due to its radioactivity. The results were compared with the recommendations of the Ministry of Health. (author)

  2. Determination of total alpha and beta activity in water for human consumption by LSC(Liquid Scintillation Counter)

    International Nuclear Information System (INIS)

    2013-01-01

    The Ordinance Brazilian of Ministry of Health (MS 2914/2011) establishes the standards for quality of water intended for human consumption, being limits values of 5.0 Bq/L for gross alpha, and 1.0 Bq/L for gross beta radioactivity. The liquid scintillation spectrometry (LSC) technique has been presented as an alternative to conventional procedure using gas flow proportional counter. The present work shows a review of the methods for determination of gross alpha and gross beta in water by using LSC. Between the factors that influence the accuracy and repeatability of the analytical results we can highlight: thermal preconcentration, type of the acid and calibration standard. A procedure was established and carried out to samples of the National Program of Intercomparison of Radionuclides in Environmental Samples for evaluation of its performance. The gross alpha and gross beta analysis in samples of the public water supplies in the Metropolitan Region of Goiania, state of Goias was carried out. The results are consistent with the guideline values form the Ministry of Health concerning radioactivity. (author)

  3. The liquid scintillation counter of the NAVF-It-district Central Norway

    International Nuclear Information System (INIS)

    Traetteberg, J.

    1979-01-01

    NAVF have placed an automatic liquid sciuntillation counter at the disposal of Prof. K. Eik-Nes of the Institute of Biophysics at Trondheim Univ.,Norges Tekniske Hoegskole. The instrument is an uncooled Searle Isocap 300, and is mainly used in biochemical research with radioactive tracers. The apparatus and its operation in 1978 are briefly described. Experience has shown that the instrument is very reliable. (JIW)

  4. Comparative study of large samples (2'' × 2'') plastic scintillators and EJ309 liquid with pulse shape discrimination (PSD) capabilities

    International Nuclear Information System (INIS)

    Iwanowska-Hanke, J; Moszynski, M; Swiderski, L; Sibczynski, P; Szczesniak, T; Krakowski, T; Schotanus, P

    2014-01-01

    In the paper we reported on the scintillation properties and pulse shape discrimination (PSD) performance of new plastic scintillators. The samples with dimension of 2 inches × 2 inches were tested: EJ299-34, EJ299-34G, EJ299-33 and EJ299-33G. They are the first commercially available plastics with neutron/gamma discrimination properties. The paper covers the measurements of emission spectra, photoelectron yield, analysis of the light pulse shapes originating from events related to gamma-rays and fast neutrons as well as neutron/gamma discrimination. The tested plastics are characterized by a photoelectron yield on a level of approximately 1600-2500 phe/MeV, depending on the sample. The highest value, measured for EJ299-34, is similar to the number of photoelectrons measured for EJ309 (2600 phe/MeV). The figure of merit (FOM) calculated for narrow energy cuts — indicating the PSD performance — showed that the PSD capabilities of the plastics are significantly lower than of EJ309. These scintillators are still under development in order to optimize the composition and manufacturing procedures. At this time the results obtained with the new plastics suggest their possible use as an alternative for liquid scintillators, especially if we consider their inflammability and non-toxicity

  5. Alpha spectrometry of environmental and food samples with photon/electron-rejecting alpha liquid-scintillation (P.E.R.A.L.S.)

    International Nuclear Information System (INIS)

    Zehringer, M.; Stockli, M.

    2006-01-01

    Full text: In environmental and food monitoring radio-nuclides are normally analysed with gamma spectrometry. Routine analysis of cesium nuclides can be realised fast and without much sample preparation. Also a few nuclides of the uranium- and thorium-series can be detected with gamma spectrometry at the low Bq/kg level. 226 Ra, 224 Ra and 228 Ra can be determined via their decay products when secular equilibrium of the sample is reached (e.g. 226 Ra via its daughters 214 Pb and 214 Bi). Alpha spectrometry is the method of choice for the determination of alpha nuclides in the mBq range. The analytes have to be separated from interfering nuclides and quenching parameters prior to the spectrometry. So, the main ask in alpha spectrometry consists in an efficient sample preparation and an alpha/beta discrimination for the spectrometric measurement. Based on the work of Jack McDowell sensitive methods for the analyses of naturally occurring nuclides such as uranium, thorium, polonium and other alpha-nuclides in water, honey and spices were developed and validated [1]. Such techniques enables the tolerance and limit values for radionuclides in food to be controlled in accordance with of the Swiss Ordinance on contaminants and Ingredients (FIV) [2] he method principle is based on a selective extraction of the alpha nuclides rom water samples rsp. from an aqueous extract of mineralized samples. The extractant has also the function of a cocktail in the alpha liquid spectrometry nd therefore the extract can be analysed directly without further clean -up Photon/Electron-Rejecting Alpha-Liquid-Scintillation, P.E.R.A.L..S. [1]). Normally, one liter of water sample is extracted with 5 ml of cocktail to achieve low detection limits. The cocktail phase is separated from the aqueous phase by use of a phase separator for liquid samples. Methods were developed for the analyses of 234 U and 238 U, the thorium nuclides 228 Th, 230 Th, 232 Th and other alpha nuclides. The achieved

  6. Scintillator structures

    International Nuclear Information System (INIS)

    Cusano, D.A.; Prener, J.S.

    1978-01-01

    Distributed phosphor scintillator structures providing superior optical coupling to photoelectrically responsive devices together with methods for fabricating said scintillator structures are disclosed. In accordance with one embodiment of the invention relating to scintillator structures, the phosphor is distributed in a 'layered' fashion with certain layers being optically transparent so that the visible wavelength output of the scintillator is better directed to detecting devices. In accordance with another embodiment of the invention relating to scintillator structures, the phosphor is distributed throughout a transparent matrix in a continuous fashion whereby emitted light is more readily transmitted to a photodetector. Methods for fabricating said distributed phosphor scintillator structures are also disclosed. (Auth.)

  7. Determination of 90Sr by liquid scintillation spectrometry in samples of contaminated water

    International Nuclear Information System (INIS)

    Ometakova, J.; Dulanska, S.

    2009-01-01

    On a model sample we optimized conditions of SPE separation of 90 Sr on Empore Sr Rad Disk in term of use eluent reagent and its appropriate concentration. Also the possibility of multiple use of both sorbents Empore Sr Rad Disk and AnaLig Sr-01 was confirmed. Not even after 8 separations radiochemical yield fall below 87%. For separation of 90 Sr from real sample of percolating water of controlled area of Bohunice NPP three commercially available products were used: 3M Empore Strontium Rad Disk, sorbents AnaLig (with different grain size) and Sr-Resin. The aim of this work was to compare the selected products in term of strontium extracts, the time demandingness and the possibility of multiple use of sorbents. For separation of strontium were also used two classical methods, namely liquid extraction with tributyl phosphate and carbonate precipitation due to the exclusion of interferents. (author)

  8. Studying, Determining The Radionuclide Of Tritum In The Water Samples (Rain, Surface Water) By Using Liquid Scintillation Counting (TRi-carb 3180TR/SL)

    International Nuclear Information System (INIS)

    Nguyen Thi Linh; Nguyen Dinh Tung; Truong Y; Le Nhu Sieu; Nguyen Van Phuc; Nguyen Van Phu; Nguyen Kim Thanh

    2014-01-01

    Tritium in the environment is of natural or man-made origin. Tritium is a radioactive isotope that occurs in the environment and is associated with the interaction of cosmic ray in the atmosphere. However, the most significant sources of tritium in the environment results from nuclear weapons testing in the atmosphere carried out during the late 1950s and early 1960s. Today, the most important new sources of tritium in the environments, such as power stations, processing and using of isotopes released the local tritium. The objective of this study is the application of the liquid scintillation technique to tritium analysis in water samples (rain, and surface waters). Following the Eichrom Tritium Column technique, an aliquot of the passed tritium resin sample (10 mL) is mixed with 10 mL of scintillation cocktail (Ultima Gold LLT, Packard) in 20-mL plastic- container vials and the sample activity is determined using a liquid scintillation spectrometer, Tri-carb 3180TR/SL. Counting efficiency is evaluated with internal standards. The tritium concentrations of water samples that were collected from DaLat, Lamdong range between 0 to 36.2 TU. (author)

  9. Scintillator structure

    International Nuclear Information System (INIS)

    Cusano, D.A.; Swank, R.K.; White, P.J.

    1978-01-01

    Scintillator structures are described in which the phosphor is embedded or suspended in an optically transparent matrix which is selected or adjusted to have an index of refraction which is approximately equal to that of the phosphor at the wavelength of the light emitted by the phosphor. The matrix may be glass, copoly 2-vinyl naphthalene/vinyl toluene or a liquid e.g. Br-naphthalene and optionally CH 3 I, the ratio of components being adjusted to give the desired refractive index. The polymer may be made in situ or a mixture of phosphor and polymer formed e.g. by freeze drying a solution and pulverizing, and then heating. Specified dyes may be used for converting the emitted light to other wavelengths. (author)

  10. Implementation of the TDCR liquid scintillation method at CNEA-LMR, Argentina.

    Science.gov (United States)

    Arenillas, Pablo; Cassette, Philippe

    2006-01-01

    During the last two years, a triple-to-double coincidence ratio (TDCR) system was assembled and adjusted at the CNEA-LMR, Argentina. The new counting system will add complementary capabilities to the absolute measurements section of the CNEA-LMR. This work describes its implementation and validation. Several checks and a set of beta-emitting standard solutions were used in order to perform the validation experiments. In preliminary measurements, a 3H LNHB solution with reference activity concentration of (119.7+/-0.9) kBq/g on 11 November 2003 was used. The CNEA-LMR TDCR counter gave, at the same reference date, an activity concentration of (120+/-1) kBq/g. Results and improvements are presented in detail. Concerning the asymmetry of the system, the quantum efficiency of the three photomultiplier tubes was studied for different operating conditions of the focusing voltage. The counter also includes an automatic system to change the efficiency by defocusing the photomultipliers and on the other hand, it was coupled to a HPGe detector to also measure beta-gamma coincidences.

  11. Implementation of the TDCR liquid scintillation method at CNEA-LMR, Argentina

    Energy Technology Data Exchange (ETDEWEB)

    Arenillas, Pablo [Laboratorio de Metrologia de Radioisotopos, Comision Nacional de Energia Atomica (Argentina); Cassette, Philippe [Laboratoire National Henri Becquerel, LNE-LNHB, 91191, Gif sur Yvette cedex (France)

    2006-10-15

    During the last two years, a triple-to-double coincidence ratio (TDCR) system was assembled and adjusted at the CNEA-LMR, Argentina. The new counting system will add complementary capabilities to the absolute measurements section of the CNEA-LMR. This work describes its implementation and validation. Several checks and a set of beta-emitting standard solutions were used in order to perform the validation experiments. In preliminary measurements, a {sup 3}H LNHB solution with reference activity concentration of (119.7{+-}0.9) kBq/g on 11 November 2003 was used. The CNEA-LMR TDCR counter gave, at the same reference date, an activity concentration of (120{+-}1) kBq/g. Results and improvements are presented in detail. Concerning the asymmetry of the system, the quantum efficiency of the three photomultiplier tubes was studied for different operating conditions of the focusing voltage. The counter also includes an automatic system to change the efficiency by defocusing the photomultipliers and on the other hand, it was coupled to a HPGe detector to also measure beta-gamma coincidences.

  12. Implementation of the TDCR liquid scintillation method at CNEA-LMR, Argentina

    International Nuclear Information System (INIS)

    Arenillas, Pablo; Cassette, Philippe

    2006-01-01

    During the last two years, a triple-to-double coincidence ratio (TDCR) system was assembled and adjusted at the CNEA-LMR, Argentina. The new counting system will add complementary capabilities to the absolute measurements section of the CNEA-LMR. This work describes its implementation and validation. Several checks and a set of beta-emitting standard solutions were used in order to perform the validation experiments. In preliminary measurements, a 3 H LNHB solution with reference activity concentration of (119.7±0.9) kBq/g on 11 November 2003 was used. The CNEA-LMR TDCR counter gave, at the same reference date, an activity concentration of (120±1) kBq/g. Results and improvements are presented in detail. Concerning the asymmetry of the system, the quantum efficiency of the three photomultiplier tubes was studied for different operating conditions of the focusing voltage. The counter also includes an automatic system to change the efficiency by defocusing the photomultipliers and on the other hand, it was coupled to a HPGe detector to also measure beta-gamma coincidences

  13. Standarization of Mn-54 by liquid scintillation counting using organic samples of (C8H15 O2)2 Mn-54

    International Nuclear Information System (INIS)

    1990-01-01

    A new method of standardization of Mn 54 by liquid scintillation counting with an organic sample of (C 8 H 15 O 2 ) 2 Mn 54 is described. This procedure shows a good long term stability of samples, over 20 days, and counting efficiencies between 10% and 24% for PCS e INSTAGEL and 10% 32% for a toluene-based scintillator. The discrepancies between experimental and computed values are less that 0,9% for PCS and INSTAGEL and less than 1,2% for Toluene, in the 5-2,5 interval of quenching parameter. The global uncertainty on the activity concentrat-ion of a sample standardized by this method has been lower than 3% (Author)

  14. Comparison of the quantulus 1220 and 300SL liquid scintillation counters for the analysis of {sup 222}Rn in groundwater

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Cheol; Jung, Yoon Hee; Lee, Wanno; Choi, Guen Sik; Chung, Kun Ho; Kang, Mun Ja [Environmental Radioactivity Assessment Team, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-12-15

    Liquid scintillation counters (LSCs) are commonly used as an analytical method for detecting {sup 222}Rn in groundwater because they involve a simple sample pretreatment and allow high throughout with an autosampler. The Quantulus 1220 is the best-selling LSC in Korea, but its production was stopped. Recently, a new type of LSC, the 300SL, was introduced. In this study, the 300SL was compared with the Quantulus 1220 in order to evaluate the ability of each apparatus to detect {sup 222}Rn in groundwater. The Quantulus 1220 and 300SL were used to detect the presence of {sup 222}Rn. Radon gas was extracted from a groundwater sample using a water-immiscible cocktail in a LSC vial. The optimal analytical conditions for each LSC were determined using a {sup 222}Rn calibration source prepared with a {sup 226}Ra source. The optimal pulse shape analysis level for alpha and beta separation was 80 for the Quantulus 1220, and the corresponding pulse length index was 12 in the 300SL. The counting efficiency of the Quantulus 1220 for alpha emissions was similar to that of the 300SL, but the background count rate of the Quantulus 1220 was 10 times lower than that of the 300SL. The minimum detectable activity of the Quantulus 1220 was 0.08 Bq·L{sup -,} while that of the 300SL was 0.20 Bq·L{sup -1}. The analytical results regarding {sup 222}Rn in groundwater were less than 10% different between these LSCs. The 300SL is an LSC that is comparable to the Quantulus 1220 for detecting {sup 222}Rn in groundwater. Both LSCs can be applied to determine the levels of {sup 222}Rn in groundwater under the management of the Ministry of Environment.

  15. Concentration of 222Rn in drinking water of the Zacatecas City, measured by liquid scintillation and associated dose

    International Nuclear Information System (INIS)

    Arevalo B, C. A.; Lopez del R, H.; Davila R, J. I.; Mireles G, F.; Pinedo V, J. L.; Rios M, C.; Saucedo A, S. A.

    2017-09-01

    A study was carried out to determine the concentration of 222 Rn in samples of drinking water collected from different homes in the Zacatecas city, Mexico, whose main source of supply is groundwater. The 222 Rn radioactive gas is a product of the decay series of 238 U and is considered one of the main sources of natural radiation, since it contributes almost half of the radiation dose that a person will receive throughout his life. The 222 Rn originates in the rocks of the aquifers and dissolves in the water, which is later integrated into the distribution network of the public supply that supplies the entire population. Exposure to ionizing radiation that 222 Rn and its offspring emit can damage the DNA molecule, inducing the possible appearance of cancer. Has been demonstrated by various epidemiological studies carried out in uranium mines workers in different parts of the world, that this exposure increases the incidence of lung cancer, placing 222 Rn and their offspring as the second main cause of this type of cancer, after smoking habit. Using the technique of solvent extraction of 222 Rn in water and liquid scintillation spectrometry, water collected from 14 different households was sampled and analyzed. The average of the measured activity of 222 Rn was 2.09 Bq/L and the annual effective dose per water intake attributable to that concentration of 6.07 mSv/a. The concentration of 222 Rn in water and the annual effective dose are below 11 Bq/L and 50 mSv/a, such concentrations are the maximum limits established by the Unites States Environmental Protection Agency (US EPA) and the ICRP, respectively. The concentration of 222 Rn that is transferred from the water to the air inside a house was also calculated and the radiation dose that this concentration causes by inhalation, being 0.209 Bq/m 3 and 1,463 μ Sv a, respectively. (Author)

  16. Development of a liquid scintillation method for in vitro determination of {sup 226}Ra and {sup 228} Ra in bioassay samples

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, Paulo Cesar P.; Sousa, Wanderson O.; Juliao, Ligia M.Q.C.; Dantas, Bernardo M., E-mail: pcesar@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2011-07-01

    Radium isotopes are dispersed in the environment according to their physicochemical characteristics. The intake of {sup 226}Ra and {sup 228}Ra in humans can occur by inhalation and ingestion and the risk of internal exposure are related to their long half-lives, characteristics of the emission and biokinetics of the isotopes in the human body. The goal of this work is to develop a methodology for the analysis of {sup 226}Ra and {sup 228}Ra in excreta samples (urine and feces), using liquid scintillation technique. Excreta samples were provided by non-exposed humans for the purpose of standardizing the methodology and the establishment of a background level of radium excretion. Radium isotopes were concentrated and separated from the constituents of the sample by co-precipitation with barium sulphate. The precipitate of Ba(Ra)SO{sub 4} was filtrated and weighted for the determination of the chemical yield. The filter containing the precipitate was transferred to a scintillation vial. In the scintillation vial, 8 mL of water, 8 mL of Instagel XF and 4 mL of UltimaGold were added, forming a gel suspension, after stirring the solution. The {sup 226}Ra and {sup 228}Ra activities were determined 21 days after the precipitation of samples. The samples were counted in a liquid scintillation spectrometer. The technique presented adequate sensitivity and reproducibility for the analysis of urine and feces. The activities of {sup 226}Ra and {sup 228}Ra in excreta samples provide useful information for the identification of the main route of intake and for the assessment of the internal exposure of occupationally exposed workers and inhabitants of high background areas. (author)

  17. The study of vial and cocktail for tritium radioactivity analysis of rain water by liquid scintillation counter

    International Nuclear Information System (INIS)

    Noh, Sung Jin; Kim, Hyo Jin; Kim, Hyun; Lee, Man Woo; Jeong, Dong Hyeok; Yang, Kwang Mo; Kang, Yeong Rok; Nam, Sang Hee

    2015-01-01

    Even though the current method for tritium (3H) analysis is routine, for the case of the low level of tritium in the environment, special conditions have to be fulfilled in order to obtain accurate and reliable tritium measurements. There are very little comparative data concerning commercial scintillating cocktails. The best cocktails for measuring tritium are those based on benzene derived solvent, and the worse cocktails are those which have complex chemical composition or contain too small concentration of scintillators. The aim of study was to investigate various vials and cocktails by comparison with the combination of few different scintillation cocktails and vials in our routine measurements according to count, efficiency, and the figure of merit (FOM). The comparison of three types of vials with scintillation cocktails for tritium activity analysis of rain water shows that glass vials have higher count rates and HiSafe 3 cocktails have lower FOM

  18. Scintillation scanner

    International Nuclear Information System (INIS)

    Mehrbrodt, A.W.; Mog, W.F.; Brunnett, C.J.

    1977-01-01

    A scintillation scanner having a visual image producing means coupled through a lost motion connection to the boom which supports the scintillation detector is described. The lost motion connection is adjustable to compensate for such delays as may occur between sensing and recording scintillations. 13 claims, 5 figures

  19. Scintillation light transport and detection

    International Nuclear Information System (INIS)

    Gabriel, T.A.; Lillie, R.A.

    1986-08-01

    The MORSE neutron gamma-ray transport code has been modified to allow for the transport of scintillation light. This modified code is used to analyze the light collection characteristics of a large liquid scintillator module (18 x 18 x 350 cm 3 )

  20. Preparation of 45 Ca (HDEHP)n and (C8H15O2)2 samples for liquid scintillation counting, compared to 45CaCl2 results

    International Nuclear Information System (INIS)

    Rodriguez Barquero, L.; Los Arcos Merino, J.M.; Grau Malonda, A.

    1994-01-01

    A procedure for preparation of liquid scintillation counting organic samples of the Di-2-ethylhexyl phosphate calcium complex and the 2-ethyhexanoate calcium salt, labelled with ''45 Ca, is described. The chemical quench, the counting stability and spectral evolution of both compounds is studied in six scintillators, Toluene, Toluene-alcohol, Dioxane-napthalhene, Hisafe II, Ultima-Gold and Instagel, and compared to results obtained from a commercial solution of ''45 CaCl 2