  1. Measurement of actinides in environmental samples by Photo-Electron Rejecting Alpha Liquid Scintillation

    Energy Technology Data Exchange (ETDEWEB)

    Cadieux, J.R. [Westinghouse Savannah River Co., Aiken, SC (United States); Clark, S. [Savannah River Ecology Lab., Univ. of Georgia (United States); Fjeld, R.A.; Reboul, S.; Sowder, A. [Clemson Univ., SC (United States). Dept. of Environmental Systems Engineering

    1994-05-01

    This work describes the adaptation of extractive scintillation with a Photo-Electron Rejecting Alpha Liquid Scintillation (PERALS) (ORDELA, Inc.) spectrometer to the analysis of actinides in environmental samples from the Savannah River Site (SRS). Environmental quality assurance standards and actual water samples were treated by one of two methods; either a two step direct extraction, or for more complex samples, pretreatment by an extraction chromatographic separation prior to measurement of the alpha activity by PERALS.

  2. Liquid Scintillation Counting

    OpenAIRE

    Carlsson, Sten

    1993-01-01

    In liquid scintillation counting (LSC) we use the process of luminescense to detect ionising radiation emit$ed from a radionuclide. Luminescense is emission of visible light of nonthermal origin. 1t was early found that certain organic molecules have luminescent properties and such molecules are used in LSC. Today LSC is the mostwidespread method to detect pure beta-ernitters like tritium and carbon-14. 1t has unique properties in its efficient counting geometry, deteetability and the lack of...

  3. Scintillating properties of frozen new liquid scintillators

    CERN Document Server

    Britvich, G I; Golovkin, S V; Martellotti, G; Medvedkov, A M; Penso, G; Soloviev, A S; Vasilchenko, V G

    1999-01-01

    The light emission from scintillators which are liquid at room temperature was studied in the interval between $+20$~$^{\\circ}$C and $-120$~$^{\\circ}$C, where the phase transition from liquid to solid takes place. The light yield measured at $-120$~$^{\\circ}$C is about twice as much as that observed at $+20$~$^{\\circ}$C. By cooling the scintillator from $+20$~$^{\\circ}$C to $-120$~$^{\\circ}$C and then heating it from $-120$~$^{\\circ}$C to $+20$~$^{\\circ}$C, the light yield varies in steps at well defined temperatures, which are different for the cooling and heating processes. These hysteresis phenomena appear to be related to the solvent rather than to the dopant. The decay time of scintillation light was measured at $+20$~$^{\\circ}$C and $-120$~$^{\\circ}$C. Whilst at room temperature most of the light is emitted with a decay time of 6--8 ns, at $-120$~$^{\\circ}$C a slower component, with a decay time of 25--35 ns, becomes important.

  4. Development of a reference liquid scintillation cocktail

    CSIR Research Space (South Africa)

    Van Wyn Gaardt, WM

    2006-02-01

    Full Text Available of a scintillator dissolved in an organic solvent. The so-called scintillator solute is a material which emits a weak light flash or scintillation upon interaction with a certain quanta of radiation – the intensity of this scintillation being a... to prepare preliminary liquid scintillation cocktails. Figure 3: Maximum deviations observed between repeat measurements of the same source, displayed in red for Ultima Gold, green for XP, yellow for XI and blue for XPI. Figure 4: The counting...

  5. Radiopure Metal-Loaded Liquid Scintillator

    Energy Technology Data Exchange (ETDEWEB)

    Rosero, Richard [Brookhaven National Lab. (BNL), Upton, NY (United States). Chemistry Dept.; Yeh, Minfang [Brookhaven National Lab. (BNL), Upton, NY (United States). Chemistry Dept.

    2015-03-18

    Metal-loaded liquid scintillator plays a key role in particle and nuclear physics experiments. The applications of metal ions in various neutrino experiments and the purification methods for different scintillator components are discussed in this paper.

  6. Some rules to improve the energy resolution in alpha liquid scintillation with beta rejection

    CERN Document Server

    Aupiais, J; Dacheux, N

    2003-01-01

    Two common scintillating mixtures dedicated to alpha measurements by means of alpha liquid scintillation with pulse shape discrimination were tested: the di-isopropylnaphthalene - based and the toluene-based solvents containing the commercial cocktails Ultima Gold AB trademark and Alphaex trademark. We show the possibility to enhance the resolution up to 200% by using no-water miscible cocktails and by reducing the optical path. Under these conditions, the resolution of about 200 keV can be obtained either by the Tri Carb sup T sup M or by the Perals sup T sup M spectrometers. The time responses, e.g., the time required for a complete energy transfer between the initial interaction alpha particle-solvent and the final fluorescence of the organic scintillator, have been compared. Both cocktails present similar behavior. According to the Foerster theory, about 6-10 ns are required to complete the energy transfer. For both apparatus, the detection limits were determined for alpha emitters. The sensitivity of the...

  7. Effect Factors of Liquid Scintillation Analysis

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    <正>Over the past decades, the liquid scintillation analysis (LSA) technique remains one of the most popular experimental tools used for the quantitative analysis of radionuclide, especially low-energy β

  8. Measuring the attenuation length in liquid scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Hellgartner, Dominikus; Oberauer, Lothar; Prummer, Sabrina; Sawatzki, Julia; Zimmer, Vincenz [Technische Universitaet Muenchen, Physik Departement E15, James Franck Strasse, 85748 Garching (Germany); Ulrich, Andreas [Technische Universitaet Muenchen, Physik Departement E12, James Franck Strasse, 85748 Garching (Germany)

    2015-07-01

    The next generation of liquid scintillator detectors like the proposed LENA detector or the planned JUNO detector will feature diameters of order 30 m. Due to this vast size, the optical quality of the scintillator is of crucial importance. To determine the attenuation length of liquid scintillators, an experiment with a 5 m long measurement section was set-up in the underground laboratory in Garching. The current set-up of the experiment is presented along with a discussion of the results of the first measurements. Additionally, there is an outlook towards possible upgrades of the experiment in the future.

  9. Examinations of efficacy of Peral-S under in vitro conditions

    Directory of Open Access Journals (Sweden)

    Ašanin Ružica

    2006-01-01

    Full Text Available The examinations covered numerous clinical and referent strain of both bacteria, as well as viruses and fungi. The paper presents only one part of the examinations in which referent strains of E. coli NTCC 8116, Proteus mirabilis ATCC 19086, Staphylococcus aureus ATCC 511, Salmonella Choleraeuis ATCC 10653, Enterococcus faecalis ATCC 6055 and Bacillus cereus ATCC 11778 were used. The effect of Peral-S in concentrations of 0.25%, 0.5% and 1% on the listed strain of bacteria was examined using the suspension method at exposition times of 5, 10, 15 and 20 minutes. Examinations were also performed of the antiviral effects of Peral-S in concentrations of 0.1% to 1% and at exposure times from 30 seconds to 5 minutes on the viruses Aujeszky 257/II, P13, Newcastle virus, Coxackie B6 , Herpes simplex type I. The efficacy of the antiviral effects of Peral-S was checked on tissue cultures MDBK, AUBEK and HEP-2 using the floating technique method. Examinations also covered the fungicidal effect of Peral-S in concentrations of from 0.1% to 1%, and of 3%, 4%, and 5% at exposure times of 5, 15 and 60 minutes and cultures aged 1 to 14 days. The investigations covered fungi from the following genera: Penicillium spp., Aspergillus spp. and Mucor spp. Peral-S showed a bactericidal effect on all the examined bacteria strains, in all the applied concentrations and at all exposure times. Peral-S in a concentration of 0.1% and at an exposure time of 30 seconds had a vurcidal effect on all examined viruses. How-ever, there was no fungicidal effect of Peral-S in concentrations of 0.1% to 1% at all expo-sure times on fungi cultures aged from one to 14 days. The preparation did exhibit a fungicidal effect in a concentration of 3% in all examined fungi cultures after 60 minutes of expo-sure, while it exhibited a fungicidal effect in a concentration of 4% after 5 minutes of expo-sure on all examined fungi cultures, regardless of their age.

  10. Measurement of Radiation Damage of Water-based Liquid Scintillator and Liquid Scintillator

    CERN Document Server

    Bignell, Lindsey J; Hans, Sunej; Jaffe, David E; Rosero, Richard; Vigdor, Steven; Viren, Brett; Worcester, Elizabeth; Yeh, Minfang; Zhang, Chao

    2015-01-01

    Liquid scintillating phantoms have been proposed as a means to perform real-time 3D dosimetry for proton therapy treatment plan verification. We have studied what effect radiation damage to the scintillator will have upon this application. We have performed measurements of the degradation of the light yield and optical attenuation length of liquid scintillator and water-based liquid scintillator after irradiation by 201 MeV proton beams that deposited doses of approximately 52 Gy, 300 Gy, and 800 Gy in the scintillator. Liquid scintillator and water-based liquid scintillator (composed of $5\\%$ scintillating phase) exhibit light yield reductions of $1.74 \\pm 0.55 \\%$ and $1.31 \\pm 0.59 \\%$ after $\\approx$ 800 Gy of proton dose, respectively. Whilst some increased optical attenuation was observed in the irradiated samples, the measured reduction to the light yield is also due to damage to the scintillation light production. Based on our results and conservative estimates of the expected dose in a clinical conte...

  11. Characterization of liquid scintillation detectors

    CERN Document Server

    Schmidt, D; Böttger, R; Klein, H; Lebreton, L; Neumann, S; Nolte, R; Pichenot, G

    2002-01-01

    Five scintillation detectors of different scintillator size and type were characterized. The pulse height scale was calibrated in terms of electron light output units using photon sources. The response functions for time-of-flight (TOF)-selected monoenergetic neutrons were experimentally determined and also simulated with the NRESP code over a wide energy range. A comparison of the measured and calculated response functions allows individual characteristics of the detectors to be determined and the response matrix to be reliably derived. Various applications are discussed.

  12. Quality study of the purified liquid scintillator

    Science.gov (United States)

    Konno, Y.; Nakajima, K.; Kibe, Y.

    2008-07-01

    We have been distilling the KamLAND liquid scintillator (LS) for the low energy solar neutrino observation. The distillation removes radioactive impurities from LS efficiently. We developed two types of high sensitivity radon detectors to monitor 222Rn contamination which causes a primary background source 210Pb. Their required sensitivity is several mBq/m3. The features and the measurement results of these detectors are presented. We also report the study of liquid scintillator properties after the distillation: attenuation length, light output and PPO density.

  13. Development of new Polysiloxane Based Liquid Scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Dalla Palma, M.; Quaranta, A. [Department of Industrial Engineering, University of Trento,Via Sommarive, 9, 38123 Trento (Italy); INFN, Laboratori Nazionali di Legnaro,Viale dell' Universita, 2, 35020 Legnaro - Padova (Italy); Gramegna, F.; Marchi, T.; Cinausero, M. [INFN, Laboratori Nazionali di Legnaro,Viale dell' Universita, 2, 35020 Legnaro - Padova (Italy); Carturan, S.; Collazuol, G.; Checchia, C. [INFN, Laboratori Nazionali di Legnaro,Viale dell' Universita, 2, 35020 Legnaro - Padova (Italy); Department of Physics and Astronomy, University of Padova, Via Marzolo, 8, 35131 Padova (Italy); Degerlier, M. [Department of Physics, Nevsehir Haci Bektas Veli University, Science and Art Faculty, 50300 Nevsehir (Turkey)

    2015-07-01

    In the last decade, attention toward neutron detection has been growing in the scientific community, driven by new requirements in different fields of application ranging from homeland security to medical and material analysis, from research physics, to nuclear energy production. So far neutron detection, with particular attention to fast neutrons, has been mainly based on organic liquid scintillators, owing to their good efficiency and pulse shape discrimination (PSD) capability. Most of these liquids have however some main drawbacks given by toxicity, flammability, volatility and sensitivity to dissolved oxygen that limits the duration and the quality of their performances with worse handiness and increased costs. Phenyl-substituted polysiloxanes could address most of these issues, being characterized by low toxicity, low volatility and low flammability. Their optical properties can be tailored by changing the phenyl distribution and concentration thus allowing to increase the solubility of organic dyes, to modify the fluorescence spectra and to vary the refractive index of the medium. Furthermore, polysiloxanes have been recently exploited for the production of plastic scintillators with very good chemical and thermal stability and very good radiation hardness and the development of polysiloxane liquid scintillators could allow to combine these interesting properties with the supremacy of liquid scintillators as regarding PSD over plastics. For these reasons, the properties of several phenyl-substituted polysiloxane with different phenyl amounts and different viscosities have been investigated, with particular attention to the scintillation response and the pulse shape discrimination capability, and the results of the investigation are reported in this work. More in details, the scintillation light yield towards gamma rays ({sup 60}Co and {sup 137}Cs) of several polysiloxane liquids has been analyzed and compared with the light yield of a commercial non

  14. Near-infrared scintillation of liquid argon

    Energy Technology Data Exchange (ETDEWEB)

    Alexander, T. [Fermilab; Escobar, C. O. [Campinas State U.; Lippincott, W. H. [Fermilab; Rubinov, P. [Fermilab

    2016-03-03

    Since the 1970s it has been known that noble gases scintillate in the near infrared (NIR) region of the spectrum (0.7 $\\mu$m < $\\lambda$; < 1.5$\\mu$m). More controversial has been the question of the NIR light yield for condensed noble gases. We first present the motivation for using the NIR scintillation in liquid argon detectors, then briefly review early as well as more recent efforts and finally show encouraging preliminary results of a test performed at Fermilab.

  15. Near-infrared scintillation of liquid argon

    CERN Document Server

    Alexander, T; Lippincott, W H; Rubinov, P

    2016-01-01

    Since the 1970s it has been known that noble gases scintillate in the near infrared (NIR) region of the spectrum (0.7 $\\mu$m < $\\lambda$; < 1.5$\\mu$m). More controversial has been the question of the NIR light yield for condensed noble gases. We first present the motivation for using the NIR scintillation in liquid argon detectors, then briefly review early as well as more recent efforts and finally show encouraging preliminary results of a test performed at Fermilab.

  16. The scintillation of liquid argon

    CERN Document Server

    Heindl, T; Hofmann, M; Krücken, R; Oberauer, L; Potzel, W; Wieser, J; Ulrich, A

    2015-01-01

    A spectroscopic study of liquid argon from the vacuum ultraviolet at 110 nm to 1000 nm is presented. Excitation was performed using continuous and pulsed 12 keV electron beams. The emission is dominated by the analogue of the so called 2nd excimer continuum. Various additional emission features were found. The time structure of the light emission has been measured for a set of well defined wavelength positions. The results help to interpret literature data in the context of liquid rare gas detectors in which the wavelength information is lost due to the use of wavelength shifters.

  17. Characterization of a new plastic scintillation material and comparison with liquid BC-501A scintillator

    OpenAIRE

    Poleshchuk, Oleksii

    2015-01-01

    In this work the capability of various scintillation materials to discriminate gamma rays and neutrons were studied. Also such basic properties of scintillators as light emission spectrum and light output were determined. The studied materials were BC-501A liquid scintillator and a plastic scintillator provided by CEA. An experimental setup consisting of detector shielding, analog and digital electronics and data acquisition system was built to study the neutron-gamma discrimination propertie...

  18. Light propagation and fluorescence quantum yields in liquid scintillators

    Science.gov (United States)

    Buck, C.; Gramlich, B.; Wagner, S.

    2015-09-01

    For the simulation of the scintillation and Cherenkov light propagation in large liquid scintillator detectors a detailed knowledge about the absorption and emission spectra of the scintillator molecules is mandatory. Furthermore reemission probabilities and quantum yields of the scintillator components influence the light propagation inside the liquid. Absorption and emission properties are presented for liquid scintillators using 2,5-Diphenyloxazole (PPO) and 4-bis-(2-Methylstyryl)benzene (bis-MSB) as primary and secondary wavelength shifter. New measurements of the quantum yields for various aromatic molecules are shown.

  19. Light propagation and fluorescence quantum yields in liquid scintillators

    CERN Document Server

    Buck, C; Wagner, S

    2015-01-01

    For the simulation of the scintillation and Cherenkov light propagation in large liquid scintillator detectors a detailed knowledge about the absorption and emission spectra of the scintillator molecules is mandatory. Furthermore reemission probabilities and quantum yields of the scintillator components influence the light propagation inside the liquid. Absorption and emission properties are presented for liquid scintillators using 2,5-Diphenyloxazole (PPO) and 4-bis-(2-Methylstyryl)benzene (bis-MSB) as primary and secondary wavelength shifter. New measurements of the quantum yields for various aromatic molecules are shown.

  20. Examinations of efficacy of Peral-S under in vitro conditions

    OpenAIRE

    Ašanin Ružica; Mišić Dušan

    2006-01-01

    The examinations covered numerous clinical and referent strain of both bacteria, as well as viruses and fungi. The paper presents only one part of the examinations in which referent strains of E. coli NTCC 8116, Proteus mirabilis ATCC 19086, Staphylococcus aureus ATCC 511, Salmonella Choleraeuis ATCC 10653, Enterococcus faecalis ATCC 6055 and Bacillus cereus ATCC 11778 were used. The effect of Peral-S in concentrations of 0.25%, 0.5% and 1% on the listed strain of bacteria was examined using ...

  1. Large-scale liquid scintillation detectors for solar neutrinos

    Energy Technology Data Exchange (ETDEWEB)

    Benziger, Jay B.; Calaprice, Frank P. [Princeton University Princeton, Princeton, NJ (United States)

    2016-04-15

    Large-scale liquid scintillation detectors are capable of providing spectral yields of the low energy solar neutrinos. These detectors require > 100 tons of liquid scintillator with high optical and radiopurity. In this paper requirements for low-energy neutrino detection by liquid scintillation are specified and the procedures to achieve low backgrounds in large-scale liquid scintillation detectors for solar neutrinos are reviewed. The designs, operations and achievements of Borexino, KamLAND and SNO+ in measuring the low-energy solar neutrino fluxes are reviewed. (orig.)

  2. Liquid scintillator production for the NOvA experiment

    CERN Document Server

    Mufson, S; Bower, C; Coan, T; Cooper, J; Corwin, L; Karty, J; Mason, P; Pla-Dalmau, A; Proudfoot, M

    2015-01-01

    The NOvA collaboration blended and delivered 8.8 kt (2.72M gal) of liquid scintillator to its detectors as its active detector medium. The composition of the scintillator was developed to meet the requirements of the experiment. The scintillator was shipped to the NOvA near and far detectors using dedicated stainless steel tanker trailers. A rigorous set of quality control procedures were put in place to assure that the liquid scintillator was blended to satisfy the transparency, light yield, and conductivity requirements. The incoming components, the blended scintillator, and the scintillator in the transport tanker trailers were all qualified with these procedures, which ensured that the NOvA scintillator was high quality and met its performance requirements.

  3. Proton recoils in organic liquid scintillator

    Energy Technology Data Exchange (ETDEWEB)

    Winter, Juergen [Technische Universitaet Muenchen, Physik Department E15, Garching (Germany); Collaboration: LENA Working Group

    2012-07-01

    In liquid-scintillator detectors like the LENA (Low Energy Neutrino Astronomy) project, understanding the nature of proton recoils is vital. First of all concerning the observation of the diffuse Supernova anti {nu}{sub e} background with the inverse beta decay (IBD). This signature can be mimicked by the thermalization and capture of a knockout neutron originating from inelastic NC interactions of atmospheric neutrinos on {sup 12}C. However, with the help of pulse shape discrimination between the neutron-induced proton recoils and the prompt positron signal from the IBD, this background might be reduced effectively. Furthermore, elastic {nu}-p scattering is an important channel for neutrinos from a galactic core-collapse SN. In order to reconstruct the initial neutrino energy, the energy-dependent quenching factor of proton recoils has to be known. Therefore, a neutron scattering experiment at the Maier-Leibnitz-Laboratorium in Garching has been set up in order to understand the response of proton recoils in organic liquid scintillator.

  4. Liquid scintillator production for the NOvA experiment

    Energy Technology Data Exchange (ETDEWEB)

    Mufson, S., E-mail: mufson@indiana.edu [Indiana University, Bloomington, IN 47405 (United States); Baugh, B.; Bower, C. [Indiana University, Bloomington, IN 47405 (United States); Coan, T.E. [Southern Methodist University, Dallas, TX 75275 (United States); Cooper, J. [Fermi National Accelerator Laboratory, Batavia, IL 60510 (United States); Corwin, L. [South Dakota School of Mines and Technology, Rapid City, SD 57701 (United States); Karty, J.A. [Indiana University, Bloomington, IN 47405 (United States); Mason, P. [University of Tennessee, Knoxville, TN 37916 (United States); Messier, M.D. [Indiana University, Bloomington, IN 47405 (United States); Pla-Dalmau, A. [Fermi National Accelerator Laboratory, Batavia, IL 60510 (United States); Proudfoot, M. [Renkert Oil, Morgantown, PA 19543 (United States)

    2015-11-01

    The NOvA collaboration blended and delivered 8.8 kt (2.72M gal) of liquid scintillator as the active detector medium to its near and far detectors. The composition of this scintillator was specifically developed to satisfy NOvA's performance requirements. A rigorous set of quality control procedures was put in place to verify that the incoming components and the blended scintillator met these requirements. The scintillator was blended commercially in Hammond, IN. The scintillator was shipped to the NOvA detectors using dedicated stainless steel tanker trailers cleaned to food grade.

  5. Cherenkov and Scintillation Light Separation in Organic Liquid Scintillators

    CERN Document Server

    Caravaca, J; Land, B J; Yeh, M; Gann, G D Orebi

    2016-01-01

    The CHErenkov / Scintillation Separation experiment (CHESS) has been used to demonstrate the separation of Cherenkov and scintillation light in both linear alkylbenzene (LAB) and LAB with 2g/L of PPO as a fluor (LAB/PPO). This is the first such demonstration for the more challenging LAB/PPO cocktail and improves on previous results for LAB. A time resolution of 338 +/- 12 ps FWHM results in an efficiency for identifying Cherenkov photons in LAB/PPO of 70 +/- 3% and 63 +/- 8% for time- and charge-based separation, respectively, with scintillation contamination of 36 +/- 5% and 38 +/- 4%. LAB/PPO data is consistent with a rise time of 0.75 +/- 0.25 ns.

  6. Measurements of proportional scintillation in liquid xenon using thin wires

    CERN Document Server

    Aprile, E; Goetzke, L W; Fernandez, A J Melgarejo; Messina, M; Naganoma, J; Plante, G; Rizzo, A; Shagin, P; Wall, R

    2014-01-01

    Proportional scintillation in liquid xenon has a promising application in the field of direct dark matter detection, potentially allowing for simpler, more sensitive detectors. However, knowledge of the basic properties of the phenomenon as well as guidelines for its practical use are currently limited. We report here on measurements of proportional scintillation light emitted in liquid xenon around thin wires. The maximum proportional scintillation gain of $287^{+97}_{-75}$ photons per drift electron was obtained using 10 $\\mu$m diameter gold plated tungsten wire. The thresholds for electron multiplication and proportional scintillation are measured as $725^{+48}_{-139}$ and $412^{+10}_{-133}$ kV/cm, respectively. The threshold for proportional scintillation is in good agreement with a previously published result, while the electron multiplication threshold represents a novel measurement. A complete set of parameters for the practical use of the electron multiplication and proportional scintillation processe...

  7. Study Performance of Liquid Scintillation Fiber Detector

    CERN Document Server

    Zhang, Yongpeng; Lu, Haoqi; Zhang, Peng; Zhang, Chengcai; Yang, Changgen

    2016-01-01

    Liquid scintillator (LS) with optical fiber detector (LSOF detector) is a new type of detector, which has been applied in large-scale particle physics experiments in recent years. We were proposing LSOF detector as one option of top veto detector in Jiangmen Underground Neutrino Observatory (JUNO) experiment. The prototype detector was located in laboratory of the institute of high energy physics (IHEP). From prototype study, we found that the detector have a good performance and can satisfy JUNO requirement. The detection efficiency of cosmic ray muon is greater than 98% and can collect 58 photon electrons (p.e.) when muon is going through the detector. Further more, the relationship between p.e., material reflectivity and LS depth are studied. We also compared the data with Monte Carlo simulation, and they have a good agreement with each other.

  8. Radon measurement using a liquid scintillation spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Koga, Taeko; Morishima, Hiroshige; Kawai, Hiroshi; Kondo, Sohei (Kinki Univ., Higashi-Osaka, Osaka (Japan). Atomic Energy Research Inst.); Mifune, Masaki; Konishi, Masanobu; Shirai, Chiaki

    1992-12-01

    A convenient radon detecting device for the purpose of estimating natural radiation exposure is described. The [alpha] radioactivity of radon gas absorbed in fine active carbon particles exposed to air is measured with a liquid scintillation spectrometer (Packard-PICO-RAD system). Its detection limits are 2mBq/l in air and 0.5 Bq/l in water with an accuracy of about 10 %. Radon concentrations at Misasa hot springs in Tottori prefecture were measured using this method. They were 0.16 [approx] 7.7 Bq/l in a bath room and 0.057 [approx] 0.36 Bq/l outdoors. Radon concentrations of the hot springs were 82 [approx] 1,700 Bq/l. (author).

  9. Rare-earth loaded liquid scintillator (for LENS experiment)

    CERN Document Server

    Barabanov, I R; Kornoukhov, V N; Yanovich, E A; Zatsepin, G T; Danilov, N A; Korpusov, G V; Kostukova, G V; Krylov, Y S; Yakshin, V V

    1999-01-01

    Rare-earth (Yb/Gd) complexes with neutral organophosphorus ligands are briefly discussed for their application in liquid scintillation technique. To evaluate the principal feasibility of rare-earth loaded scintillator, the ytterbium chloride complexes with tri-isoamylphosphine oxides were synthesized. Relative scintillation efficiency (RSE) for two Yb concentrations (78 and 88 g/L) was measured by means of the internal conversion exitation from Cs-137. The results obtained were 50 and 40% respectively.

  10. Measurement of scintillation efficiency for nuclear recoils in liquid argon

    CERN Document Server

    Gastler, D; Hime, A; Stonehill, L C; Seibert, S; Klein, J; Lippincott, W H; McKinsey, D N; Nikkel, J A

    2010-01-01

    The scintillation light yield of liquid argon from nuclear recoils relative to electronic recoils has been measured as a function of recoil energy from 10 keVr up to 250 keVr. The scintillation efficiency, defined as the ratio of the nuclear recoil scintillation response to the electronic recoil response, is 0.25 \\pm 0.02 + 0.01(correlated) above 20 keVr.

  11. Alpha counting and spectrometry using liquid scintillation methods

    Energy Technology Data Exchange (ETDEWEB)

    McDowell, W J

    1986-01-01

    The material in this report is intended to be a practical introduction and guide to the use of liquid scintillation for alpha counting and spectrometry. Other works devoted to the development of the theory of liquid scintillation exist and a minimum of such material is repeated here. Much remains to be learned and many improvements remain to be made in the use of liquid scintillation for alpha counting and spectrometry. It is hoped that this modest work will encourage others to continue development in the field.

  12. Liquid xenon scintillators for imaging of positron emitters.

    Science.gov (United States)

    Lavoie, L

    The current understanding of xenon scintillation physics is summarized and keyed to the use of xenon as a gamma-ray detector in medical radioisotope imaging systems. Liquid xenon has a short scintillation pulse (approximately 10(8) sec) and high gamma-ray absorption and scintillation efficiencies. The fast pulse may facilitate imaging in vivo distributions of hot positron sources and allow recovery of additional spatial information by time-of-flight techniques. We begin by describing our own study of the feasibility of making a practical positron scanning system, and consider the problems of scintillation decay time, linearity, efficiency, purity, and electricfield amplifcation. The prospects for a practical instrument are considered.

  13. Reactor Neutrino Experiments with a Large Liquid Scintillator Detector

    CERN Document Server

    Kopp, J F; Merle, A; Rolinec, M

    2007-01-01

    We discuss several new ideas for reactor neutrino oscillation experiments with a Large Liquid Scintillator Detector. We consider two different scenarios for a measurement of the small mixing angle $\\theta_{13}$ with a mobile $\\bar{\

  14. Fine grained electromagnetic lead-liquid scintillator calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Bachman, L.; Fluri, L.; Perrin, D.; Vuilleumier, J.M. (Neuchatel Univ. (Switzerland)); Bonesini, M.; Cavalli, D.; Costa, G.; Mandelli, L.; Mazzanti, M.; Tamborini, M. (Istituto Nazionale di Fisica Nucleare, Milan (Italy))

    1983-02-15

    A new technique using liquid scintillator contained in teflon tubes to build a low cost high spatial resolution electromagnetic sampling calorimeter is described. Test results and comparison with a Monte Carlo simulation are presented.

  15. Scintillation of liquid neon from electronic and nuclear recoils

    CERN Document Server

    Nikkel, J A; Lippincott, W H; McKinsey, D N

    2006-01-01

    We have measured the time dependence of scintillation light from electronic and nuclear recoils in liquid neon, finding a slow time constant of 15.4+-0.2 us. Pulse shape discrimination is investigated as a means of identifying event type in liquid neon. Finally, the nuclear recoil scintillation efficiency is measured to be 0.26+-0.03 for 387 keV nuclear recoils.

  16. Oxygen quenching in LAB based liquid scintillator and nitrogen bubbling

    CERN Document Server

    Hua-Lin, Xiao

    2009-01-01

    Oxygen quenching effect in Linear Alkl Benzne (LAB) based liquid scintillator (LAB+3g/L POPOP+ 15 mg Bis--MSB) was studied by measuring the light yield as the function of nitrogen bubbling time. it shows that the light yield of fully purged liquid scintillator would increase of nearly 11% in room temperature and room atmosphere pressure. A simple model of nitrogen bubbling was built to describe the relationship between relative light yield (oxygen quenching factor) and bubbling time.

  17. Scintillation yield of liquid xenon at room temperature

    Energy Technology Data Exchange (ETDEWEB)

    Ueshima, K. [Kamioka Observatory, Institute for Cosmic Ray Research, University of Tokyo, Kamioka, Hida, Gifu 506-1205 (Japan)], E-mail: ueshima@suketto.icrr.u-tokyo.ac.jp; Abe, K.; Iida, T.; Ikeda, M.; Kobayashi, K.; Koshio, Y.; Minamino, A.; Miura, M.; Moriyama, S. [Kamioka Observatory, Institute for Cosmic Ray Research, University of Tokyo, Kamioka, Hida, Gifu 506-1205 (Japan); Nakahata, M. [Kamioka Observatory, Institute for Cosmic Ray Research, University of Tokyo, Kamioka, Hida, Gifu 506-1205 (Japan); Institute for the Physics and Mathematics of the Universe, University of Tokyo, Kashiwa, Chiba 277-8582 (Japan); Nakajima, Y.; Ogawa, H.; Sekiya, H.; Shiozawa, M. [Kamioka Observatory, Institute for Cosmic Ray Research, University of Tokyo, Kamioka, Hida, Gifu 506-1205 (Japan); Suzuki, Y. [Kamioka Observatory, Institute for Cosmic Ray Research, University of Tokyo, Kamioka, Hida, Gifu 506-1205 (Japan); Institute for the Physics and Mathematics of the Universe, University of Tokyo, Kashiwa, Chiba 277-8582 (Japan); Takeda, A.; Takeuchi, Y.; Yamashita, M. [Kamioka Observatory, Institute for Cosmic Ray Research, University of Tokyo, Kamioka, Hida, Gifu 506-1205 (Japan); Kaneyuki, K. [Research Center for Cosmic Neutrinos, Institute for Cosmic Ray Research, University of Tokyo, Kashiwa, Chiba 277-8582 (Japan); Doke, T. [Faculty of Science and Engineering, Waseda University, Shinjuku-ku, Tokyo 162-8555 (Japan)] (and others)

    2008-09-01

    The intensity of scintillation light emission from liquid xenon at room temperature was measured. The scintillation light yield at 1{sup 0}C was measured to be 0.64{+-}0.02 (stat.) {+-}0.06 (sys.) of that at -100{sup 0}C. Using the reported light yield at -100{sup 0}C (46 photons/keV), the measured light yield at 1{sup 0}C corresponds to 29 photons/keV. This result shows that liquid xenon scintillator provides high light yield even at room temperature.

  18. Liquid Scintillation High Resolution Spectral Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Grau Carles, A.; Grau Malonda, A.

    2010-08-06

    The CIEMAT/NIST and the TDCR methods in liquid scintillation counting are based on the determination of the efficiency for total counting. This paper tries to expand these methods analysing the pulse-height spectrum of radionuclides. To reach this objective we have to generalize the equations used in the model and to analyse the influence of ionization and chemical quench in both spectra and counting efficiency. We present equations to study the influence of different photomultipliers response in systems with one, two or three photomultipliers. We study the effect of the electronic noise discriminator level in both spectra and counting efficiency. The described method permits one to study problems that up to now was not possible to approach, such as the high uncertainty in the standardization of pure beta-ray emitter with low energy when we apply the TDCR method, or the discrepancies in the standardization of some electron capture radionuclides, when the CIEMAT/NIST method is applied. (Author) 107 refs.

  19. Large liquid-scintillator trackers for neutrino experiments

    CERN Document Server

    Benussi, L; D'Ambrosio, N; Déclais, Y; Dupraz, J P; Fabre, Jean-Paul; Fanti, V; Forton, E; Frekers, D; Frenkel, A; Girerd, C; Golovkin, S V; Grégoire, G; Harrison, K; Jonkmans, G; Jonsson, P; Katsanevas, S; Kreslo, I; Marteau, J; Martellotti, G; Martínez, S; Medvedkov, A M; Moret, G; Niwa, K; Novikov, V; Van Beek, G; Penso, G; Vasilchenko, V G; Vuilleumier, J L; Wilquet, G; Zucchelli, P; Kreslo, I E

    2002-01-01

    Results are given on tests of large particle trackers for the detection of neutrino interactions in long-baseline experiments. Module prototypes have been assembled using TiO$_2$-doped polycarbonate panels. These were subdivided into cells of $\\sim 1$~cm$^2$ cross section and 6~m length, filled with liquid scintillator. A wavelength-shifting fibre inserted in each cell captured a part of the scintillation light emitted when a cell was traversed by an ionizing particle. Two different fibre-readout systems have been tested: an optoelectronic chain comprising an image intensifier and an Electron Bombarded CCD (EBCCD); and a hybrid photodiode~(HPD). New, low-cost liquid scintillators have been investigated for applications in large underground detectors. Testbeam studies have been performed using a commercially available liquid scintillator. The number of detected photoelectrons for minimum-ionizing particles crossing a module at different distances from the fibre readout end was 6 to 12 with the EBCCD chain and ...

  20. Fluorescence decay-time constants in organic liquid scintillators.

    Science.gov (United States)

    Marrodán Undagoitia, T; von Feilitzsch, F; Oberauer, L; Potzel, W; Ulrich, A; Winter, J; Wurm, M

    2009-04-01

    The fluorescence decay-time constants have been measured for several scintillator mixtures based on phenyl-o-xylylethane (PXE) and linear alkylbenzene (LAB) solvents. The resulting values are of relevance for the physics performance of the proposed large-volume liquid scintillator detector Low Energy Neutrino Astronomy (LENA). In particular, the impact of the measured values to the search for proton decay via p-->K(+)nu is evaluated in this work.

  1. Measurement of Scintillation and Ionization Yield and Scintillation Pulse Shape from Nuclear Recoils in Liquid Argon

    CERN Document Server

    Cao, H; Avetisyan, R; Back, H O; Cocco, A G; DeJongh, F; Fiorillo, G; Galbiati, C; Grandi, L; Guardincerri, Y; Kendziora, C; Lippincott, W H; Love, C; Lyons, S; Manenti, L; Martoff, C J; Meng, Y; Montanari, D; Mosteiro, P; Olvitt, D; Pordes, S; Qian, H; Rossi, B; Saldanha, R; Sangiorgio, S; Siegl, K; Strauss, S Y; Tan, W; Tatarowicz, J; Walker, S; Wang, H; Watson, A W; Westerdale, S; Yoo, J

    2014-01-01

    We have measured the scintillation and ionization yield of recoiling nuclei in liquid argon as a function of applied electric field by exposing a dual-phase Liquid Argon Time Projection Chamber (LAr-TPC) to a low energy pulsed narrowband neutron beam produced at the Notre Dame Institute for Structure and Nuclear Astrophysics. Liquid scintillation counters were arranged to detect and identify neutrons scattered in the TPC and to select the energy of the recoiling nuclei. We report measurements of the scintillation and ionization yields for nuclear recoils with energies from 10.3 to 57.2 keV and for applied electric fields from 0 to 1000 V/cm. We also report the observation of an anti-correlation between scintillation and ionization from nuclear recoils, which is similar to the anti-correlation between scintillation and ionization from electron recoils. A comparison of the light and charge yield of recoils parallel and perpendicular to the applied electric field yielded a first evidence of sensitivity to direct...

  2. Explore nuclearites in a large liquid scintillator neutrino detector

    CERN Document Server

    Guo, Wan-Lei; Lin, Tao; Wang, Zhi-Min

    2016-01-01

    We take the JUNO experiment as an example to explore nuclearites in the future large liquid scintillator detector. Comparing to the previous calculations, the visible energy of nuclearites across the liquid scintillator will be reestimated for the liquid scintillator based detector. Then the JUNO sensitivities to the nuclearite flux are presented. It is found that the JUNO projected sensitivities can be better than $7.7 \\times 10^{-17} {\\rm cm^{-2} s^{-1} sr^{-1}}$ for the nuclearite mass $10^{15} \\; {\\rm GeV} \\leq M \\leq 10^{24}$ GeV and initial velocity $10^{-4} \\leq \\beta_0 \\leq 10^{-1}$ with a 20 year running. Note that the JUNO will give the most stringent limits for downgoing nuclearites with $1.6 \\times 10^{13} \\; {\\rm GeV} \\leq M \\leq 4.0 \\times 10^{15}$ GeV and a typical galactic velocity $\\beta_0 = 10^{-3}$.

  3. New scintillating media based on liquid crystals for particle detectors

    CERN Document Server

    Barnik, M I; Vasilchenko, V G; Golovkin, S V; Medvedkov, A M; Soloviev, A S

    2000-01-01

    The study results of optical, photoluminiscent and scintillation properties of a liquid crystal 4-pentyl-4'-cyanobiphenyl are presented. The scintillation light output of this liquid crystal is about 35% of crystal anthracene, its main decay time constants are 4 and 14 ns, and the maximum of light emission spectrum is about 400 nm. The light output of a dissolution of green emitting light scintillation dopant R6 in the liquid crystal is about 120% of crystal anthracene. The light output of the frozen dissolution measured at -112 deg. C is about 2.5 times higher as observed at +20 deg. C. In the uniaxially oriented liquid crystal, the predominant intensity direction of emitted light is pointed perpendicular to the liquid crystal director and an appreciable part of the emitted light is elliptically polarized. The possibility to use scintillation properties of liquid crystals is considered both for the improvement of existing particle detector characteristics and for the creation of new gated particle detectors.

  4. Aging research of the LAB-based liquid scintillator in stainless steel container

    OpenAIRE

    Chen, Hai-tao; Yu, Bo-Xiang; Shan, Qing; Ding, Ya-yun; Du, Bing; Liu, Shu-tong; Zhang, Xuan; Zhou, Li; Jia, Wen-bao; Fang, Jian; Ye, Xing-Chen; HU, Wei; Niu, Shun-Li; Yan, Jia-qing; Zhao, Hang

    2014-01-01

    Stainless steel is the material used for the storage vessels and piping systems of LAB-based liquid scintillator in JUNO experiment. Aging is recognized as one of the main degradation mechanisms affecting the properties of liquid scintillator. LAB-based liquid scintillator aging experiments were carried out in different material of containers (type 316 and 304 stainless steel and glass) at two different temperature (40 and 25 degrees Celsius). For the continuous liquid scintillator properties...

  5. Data analysis in solar neutrinos liquid-scintillator detectors

    Energy Technology Data Exchange (ETDEWEB)

    Testera, G. [INFN, Genova (Italy)

    2016-04-15

    This paper focuses on the description of some of the methods developed to extract the solar neutrino signal from the background by the two running experiments (Borexino and Kamland) based on the use of a large volume of liquid scintillator. (orig.)

  6. Performance of Water-Based Liquid Scintillator: An Independent Analysis

    Directory of Open Access Journals (Sweden)

    D. Beznosko

    2014-01-01

    Full Text Available The water-based liquid scintillator (WbLS is a new material currently under development. It is based on the idea of dissolving the organic scintillator in water using special surfactants. This material strives to achieve the novel detection techniques by combining the Cerenkov rings and scintillation light, as well as the total cost reduction compared to pure liquid scintillator (LS. The independent light yield measurement analysis for the light yield measurements using three different proton beam energies (210 MeV, 475 MeV, and 2000 MeV for water, two different WbLS formulations (0.4% and 0.99%, and pure LS conducted at Brookhaven National Laboratory, USA, is presented. The results show that a goal of ~100 optical photons/MeV, indicated by the simulation to be an optimal light yield for observing both the Cerenkov ring and the scintillation light from the proton decay in a large water detector, has been achieved.

  7. Measurement of scintillation and ionization yield and scintillation pulse shape from nuclear recoils in liquid argon

    Energy Technology Data Exchange (ETDEWEB)

    Cao, H.; Alexander, T.; Aprahamian, A.; Avetisyan, R.; Back, H. O.; Cocco, A. G.; DeJongh, F.; Fiorillo, G.; Galbiati, C.; Grandi, L.; Guardincerri, Y.; Kendziora, C.; Lippincott, W. H.; Love, C.; Lyons, S.; Manenti, L.; Martoff, C. J.; Meng, Y.; Montanari, D.; Mosteiro, P.; Olvitt, D.; Pordes, S.; Qian, H.; Rossi, B.; Saldanha, R.; Sangiorgio, S.; Siegl, K.; Strauss, S. Y.; Tan, W.; Tatarowicz, J.; Walker, S.; Wang, H.; Watson, A. W.; Westerdale, S.; Yoo, J.

    2015-05-01

    We have measured the scintillation and ionization yield of recoiling nuclei in liquid argon as a function of applied electric field by exposing a dual-phase liquid argon time projection chamber (LAr-TPC) to a low energy pulsed narrow band neutron beam produced at the Notre Dame Institute for Structure and Nuclear Astrophysics. Liquid scintillation counters were arranged to detect and identify neutrons scattered in the TPC and to select the energy of the recoiling nuclei. We report measurements of the scintillation yields for nuclear recoils with energies from 10.3 to 57.3 keV and for median applied electric fields from 0 to 970 V / cm . For the ionization yields, we report measurements from 16.9 to 57.3 keV and for electric fields from 96.4 to 486 V / cm . We also report the observation of an anticorrelation between scintillation and ionization from nuclear recoils, which is similar to the anticorrelation between scintillation and ionization from electron recoils. Assuming that the energy loss partitions into excitons and ion pairs from 83 m Kr internal conversion electrons is comparable to that from 207 Bi conversion electrons, we obtained the numbers of excitons ( N ex ) and ion pairs ( N i ) and their ratio ( N ex / N i ) produced by nuclear recoils from 16.9 to 57.3 keV. Motivated by arguments suggesting direction sensitivity in LAr-TPC signals due to columnar recombination, a comparison of the light and charge yield of recoils parallel and perpendicular to the applied electric field is presented for the first time.

  8. Comparing the response of PSD-capable plastic scintillator to standard liquid scintillator

    Science.gov (United States)

    Woolf, Richard S.; Hutcheson, Anthony L.; Gwon, Chul; Phlips, Bernard F.; Wulf, Eric A.

    2015-06-01

    This work discusses a test campaign to characterize the response of the recently developed plastic scintillator with pulse shape discrimination (PSD) capabilities (EJ-299-33). PSD is a property exhibited by certain types of scintillating material in which incident stimuli (fast neutrons or γ rays) can be separated by exploiting differences in the scintillation light pulse tail. Detector geometries used were: a 10 cm×10 cm×10 cm cube and a 10-cm diameter×10-cm long cylinder. EJ-301 and EJ-309 liquid scintillators with well-known responses were also tested. The work was conducted at the University of Massachusetts Lowell Van De Graaff accelerator. The facility accelerated protons on a thin Li target to yield quasi-monoenergetic neutrons from the 7Li(p,n)7Be reaction (Q-value: -1.644 MeV). Collimated fast neutrons were obtained by placing detectors behind a neutron spectrometer. Rotating the spectrometer, and thus changing the neutron energy, allowed us to achieve 0.5-3.2 MeV neutrons in 200-300 keV steps. Data were acquired through a flash analog-to-digital converter (ADC) capable of performing digital PSD measurements. By using the PSD technique to separate the neutron events from unwanted γ background, we constructed a pulse height spectrum at each energy. Obtaining a relationship of the relative light output versus energy allowed us to construct the response function for the EJ-299-33 and liquid scintillator. The EJ-299-33 response in terms of electron equivalent energy (Ee.e.) vs. proton equivalent energy (Ep.e.), how it compared with the standard xylene-based EJ-301 (or, NE-213/BC-501 A equivalent) and EJ-309 liquid scintillator response, and how the EJ-301 and EJ-309 compared, are presented. We find that the EJ-299-33 demonstrated a lower light output by up to 40% for <1.0 MeV neutrons; and ranging between a 5-35% reduction for 2.5-3.0 MeV neutrons compared to the EJ-301/309, depending on the scintillator and geometry. Monte Carlo modeling techniques were

  9. Comparing the response of PSD-capable plastic scintillator to standard liquid scintillator

    Energy Technology Data Exchange (ETDEWEB)

    Woolf, Richard S., E-mail: richard.woolf@nrl.navy.mil [High Energy Space Environment Branch, Space Science Division, U. S. Naval Research Laboratory, 4555 Overlook Ave., SW, Washington, DC 20375 (United States); Hutcheson, Anthony L., E-mail: anthony.hutcheson@nrl.navy.mil [High Energy Space Environment Branch, Space Science Division, U. S. Naval Research Laboratory, 4555 Overlook Ave., SW, Washington, DC 20375 (United States); Gwon, Chul, E-mail: chul.gwon@nrl.navy.mil [High Energy Space Environment Branch, Space Science Division, U. S. Naval Research Laboratory, 4555 Overlook Ave., SW, Washington, DC 20375 (United States); Phlips, Bernard F., E-mail: bernard.phlips@nrl.navy.mil [High Energy Space Environment Branch, Space Science Division, U. S. Naval Research Laboratory, 4555 Overlook Ave., SW, Washington, DC 20375 (United States); Wulf, Eric A., E-mail: eric.wulf@nrl.navy.mil [High Energy Space Environment Branch, Space Science Division, U. S. Naval Research Laboratory, 4555 Overlook Ave., SW, Washington, DC 20375 (United States)

    2015-06-01

    This work discusses a test campaign to characterize the response of the recently developed plastic scintillator with pulse shape discrimination (PSD) capabilities (EJ-299-33). PSD is a property exhibited by certain types of scintillating material in which incident stimuli (fast neutrons or γ rays) can be separated by exploiting differences in the scintillation light pulse tail. Detector geometries used were: a 10 cm×10 cm×10 cm cube and a 10-cm diameter×10-cm long cylinder. EJ-301 and EJ-309 liquid scintillators with well-known responses were also tested. The work was conducted at the University of Massachusetts Lowell Van De Graaff accelerator. The facility accelerated protons on a thin Li target to yield quasi-monoenergetic neutrons from the {sup 7}Li(p,n){sup 7}Be reaction (Q-value: –1.644 MeV). Collimated fast neutrons were obtained by placing detectors behind a neutron spectrometer. Rotating the spectrometer, and thus changing the neutron energy, allowed us to achieve 0.5–3.2 MeV neutrons in 200–300 keV steps. Data were acquired through a flash analog-to-digital converter (ADC) capable of performing digital PSD measurements. By using the PSD technique to separate the neutron events from unwanted γ background, we constructed a pulse height spectrum at each energy. Obtaining a relationship of the relative light output versus energy allowed us to construct the response function for the EJ-299-33 and liquid scintillator. The EJ-299-33 response in terms of electron equivalent energy (E{sub e.e.}) vs. proton equivalent energy (E{sub p.e.}), how it compared with the standard xylene-based EJ-301 (or, NE-213/BC-501 A equivalent) and EJ-309 liquid scintillator response, and how the EJ-301 and EJ-309 compared, are presented. We find that the EJ-299-33 demonstrated a lower light output by up to 40% for <1.0 MeV neutrons; and ranging between a 5–35% reduction for 2.5–3.0 MeV neutrons compared to the EJ-301/309, depending on the scintillator and geometry

  10. Scintillation time dependence and pulse shape discrimination in liquid argon

    CERN Document Server

    Lippincott, W H; Gastler, D; Hime, A; Kearns, E; McKinsey, D N; Nikkel, J A; Stonehill, L C

    2008-01-01

    Using a single-phase liquid argon detector with a signal yield of 4.85 photoelectrons per keV of electronic-equivalent recoil energy (keVee), we measure the scintillation time dependence of both electronic and nuclear recoils in liquid argon down to 5 keVee. We develop two methods of pulse shape discrimination to distinguish between electronic and nuclear recoils. Using one of these methods, we measure a background and statistics-limited level of electronic recoil contamination to be $7.6\\times10^{-7}$ between 60 and 128 keV of nuclear recoil energy (keVr) for a nuclear recoil acceptance of 50% with no nuclear recoil-like events above 72 keVr. Finally, we develop a maximum likelihood method of pulse shape discrimination using the measured scintillation time dependence and predict the sensitivity to WIMP-nucleon scattering in three configurations of a liquid argon dark matter detector.

  11. Optical Design Considerations for Efficient Light Collection from Liquid Scintillation Counters

    Energy Technology Data Exchange (ETDEWEB)

    Bernacki, Bruce E.; Douglas, Matthew; Erchinger, Jennifer L.; Fuller, Erin S.; Keillor, Martin E.; Morley, Shannon M.; Mullen, Crystal A.; Orrell, John L.; Panisko, Mark E.; Warren, Glen A.; Wright, Michael E.

    2015-01-01

    Liquid scintillation counters measure charged particle-emitting radioactive isotopes and are used for environmental studies, nuclear chemistry, and life science. Alpha and beta emissions arising from the material under study interact with the scintillation cocktail to produce light. The prototypical liquid scintillation counter employs low-level photon-counting detectors to measure the arrival of the scintillation light produced as a result of the dissolved material under study interacting with the scintillation cocktail. For reliable operation the counting instrument must convey the scintillation light to the detectors efficiently and predictably. Current best practices employ the use of two or more detectors for coincidence processing to discriminate true scintillation events from background events due to instrumental effects such as photomultiplier tube dark rates, tube flashing, or other light emission not generated in the scintillation cocktail vial. In low background liquid scintillation counters additional attention is paid to shielding the scintillation cocktail from naturally occurring radioactive material (NORM) present in the laboratory and within the instruments construction materials. Low background design is generally at odds with optimal light collection. This study presents the evolution of a light collection design for liquid scintillation counting in a low background shield. The basic approach to achieve both good light collection and a low background measurement is described. The baseline signals arising from the scintillation vial are modeled and methods to efficiently collect scintillation light are presented as part of the development of a customized low-background, high sensitivity liquid scintillation counting system.

  12. Measuring the 14C content in liquid scintillators

    Science.gov (United States)

    Enqvist, T.; Barabanov, I. R.; Bezrukov, L. B.; Gangapshev, A. M.; Gavrilyuk, Y. M.; Grishina, V. Yu; Gurentsov, V. I.; Hissa, J.; Joutsenvaara, J.; Kazalov, V. V.; Krokhaleva, S.; Kutuniva, J.; Kuusiniemi, P.; Kuzminov, V. V.; Kurlovich, A. S.; Loo, K.; Lubsandorzhiev, B. K.; Lubsandorzhiev, S.; Morgalyuk, V. P.; Novikova, G. Y.; Pshukov, A. M.; Sinev, V. V.; Słupecki, M.; Trzaska, W. H.; Umerov, Sh I.; Veresnikova, A. V.; Virkajärvi, A.; Yanovich, Y. A.; Zavarzina, V. P.

    2016-05-01

    We are going to perform a series of measurements where the 14C/12 C ratio will be measured from several liquid scintillator samples with a dedicated setup. The setup is designed with the aim of measuring ratios smaller than 10-18. Measurements take place in two underground laboratories: in the Baksan Neutrino Observatory, Russia and in the Pyhäsalmi mine, Finland. In Baksan the measurements started in 2015 and in Pyhäsalmi they start in the beginning of 2015. In order to fully understand the operation of the setup and its background contributions a development of simulation packages has also been started. Low-energy neutrino detection with a liquid scintillator requires that the intrinsic 14C content in the liquid is extremely low. In the Borexino CTF detector at Gran Sasso, Italy the 14C/12C ratio of 2 × 10-18 has been achieved being the lowest 14C concentration ever measured. In principle, the older the oil or gas source that the liquid scintillator is derived of and the deeper it situates, the smaller the 14C/12C ratio is supposed to be. This, however, is not generally the case, and the ratio is probably determined by the U and Th content of the local environment.

  13. Characterization of positronium properties in doped liquid scintillators

    CERN Document Server

    Consolati, G; Hans, S; Jollet, C; Meregaglia, A; Perasso, S; Tonazzo, A; Yeh, M

    2013-01-01

    Ortho-positronium (o-Ps) formation and decay can replace the annihilation process, when positron interacts in liquid scintillator media. The delay induced by the positronium decay represents either a potential signature for anti-neutrino detection, via inverse beta decay, or to identify and suppress positron background, as recently demonstrated by the Borexino experiment. The formation probability and decay time of o-Ps depend strongly on the surrounding material. In this paper, we characterize the o-Ps properties in liquid scintillators as function of concentrations of gadolinium, lithium, neodymium, and tellurium, dopers used by present and future neutrino experiments. In particular, gadolinium and lithium are high neutron cross section isotopes, widely used in reactor anti-neutrino experiments, while neodymium and tellurium are double beta decay emitters, employed to investigates the Majorana neutrino nature. Future neutrino experiments may profit from the performed measurements to tune the preparation of ...

  14. SBIR Final Report. Liquid Core Optical Scintillating Fibers

    Energy Technology Data Exchange (ETDEWEB)

    Beetz, C.P.; Steinbeck, J.; Buerstler, R.

    2000-05-16

    This Phase I SBIR project focused on developing flexible scintillating liquid core optical fibers, with potential uses in high-energy calorimetry, tracking, preradiators, active targets or other fast detectors. Progress on the six tasks of the project is summarized. The technical developments involve three technology components: (1) highly flexible capillaries or tubes of relatively low n (index of refraction) to serve as cladding and liquid core containment; (2) scintillator (and clear) fluids of relatively high n to serve as a core-- these fluids must have a high light transmission and, for some applications, radiation hardness; (3) optical end plugs, plug insertion, and plug-cladding tube sealing technology to contain the core fluids in the tubes, and to transmit the light.

  15. Optical Properties of Quantum-Dot-Doped Liquid Scintillators

    CERN Document Server

    Aberle, C; Weiss, S; Winslow, L

    2013-01-01

    Semiconductor nanoparticles (quantum dots) were studied in the context of liquid scintillator development for upcoming neutrino experiments. The unique optical and chemical properties of quantum dots are particularly promising for the use in neutrinoless double beta decay experiments. Liquid scintillators for large scale neutrino detectors have to meet specific requirements which are reviewed, highlighting the peculiarities of quantum-dot-doping. In this paper, we report results on laboratory-scale measurements of the attenuation length and the fluorescence properties of three commercial quantum dot samples. The results include absorbance and emission stability measurements, improvement in transparency due to filtering of the quantum dot samples, precipitation tests to isolate the quantum dots from solution and energy transfer studies with quantum dots and the fluorophore PPO.

  16. Optical properties of quantum-dot-doped liquid scintillators

    Science.gov (United States)

    Aberle, C.; Li, J. J.; Weiss, S.; Winslow, L.

    2013-10-01

    Semiconductor nanoparticles (quantum dots) were studied in the context of liquid scintillator development for upcoming neutrino experiments. The unique optical and chemical properties of quantum dots are particularly promising for the use in neutrinoless double-beta decay experiments. Liquid scintillators for large scale neutrino detectors have to meet specific requirements which are reviewed, highlighting the peculiarities of quantum-dot-doping. In this paper, we report results on laboratory-scale measurements of the attenuation length and the fluorescence properties of three commercial quantum dot samples. The results include absorbance and emission stability measurements, improvement in transparency due to filtering of the quantum dot samples, precipitation tests to isolate the quantum dots from solution and energy transfer studies with quantum dots and the fluorophore PPO.

  17. The next-generation liquid-scintillator neutrino observatory LENA

    CERN Document Server

    Wurm, Michael; Bezrukov, Leonid B; Bick, Daniel; Blümer, Johannes; Choubey, Sandhya; Ciemniak, Christian; D'Angelo, Davide; Dasgupta, Basudeb; Dighe, Amol; Domogatsky, Grigorij; Dye, Steve; Eliseev, Sergey; Enqvist, Timo; Erykalov, Alexey; von Feilitzsch, Franz; Fiorentini, Gianni; Fischer, Tobias; Göger-Neff, Marianne; Grabmayr, Peter; Hagner, Caren; Hellgartner, Dominikus; Hissa, Johannes; Horiuchi, Shunsaku; Janka, Hans-Thomas; Jaupart, Claude; Jochum, Josef; Kalliokoski, Tuomo; Kuusiniemi, Pasi; Lachenmaier, Tobias; Lazanu, Ionel; Learned, John G; Lewke, Timo; Lombardi, Paolo; Lorenz, Sebastian; Lubsandorzhiev, Bayarto; Ludhova, Livia; Loo, Kai; Maalampi, Jukka; Mantovani, Fabio; Marafini, Michela; Maricic, Jelena; Undagoitia, Teresa Marrodán; McDonough, William F; Miramonti, Lino; Mirizzi, Alessandro; Meindl, Quirin; Mena, Olga; Möllenberg, Randolph; Nahnhauer, Rolf; Nesterenko, Dmitry; Novikov, Yuri N; Nuijten, Guido; Oberauer, Lothar; Pakvasa, Sandip; Palomares-Ruiz, Sergio; Pallavicini, Marco; Pascoli, Silvia; Patzak, Thomas; Peltoniemi, Juha; Potzel, Walter; Räihä, Tomi; Raffelt, Georg G; Ranucci, Gioacchino; Razzaque, Soebur; Rummukainen, Kari; Sarkamo, Juho; Sinev, Valerij; Spiering, Christian; Stahl, Achim; Thorne, Felicitas; Tippmann, Marc; Tonazzo, Alessandra; Trzaska, Wladyslaw H; Vergados, John D; Wiebusch, Christopher; Winter, Jürgen

    2011-01-01

    We propose the liquid-scintillator detector LENA (Low Energy Neutrino Astronomy) as a next-generation neutrino observatory on the scale of 50 kt. The outstanding successes of the Borexino and KamLAND experiments demonstrate the large potential of liquid-scintillator detectors in low-energy neutrino physics. LENA's physics objectives comprise the observation of astrophysical and terrestrial neutrino sources as well as the investigation of neutrino oscillations. In the GeV energy range, the search for proton decay and long-baseline neutrino oscillation experiments complement the low-energy program. Based on the considerable expertise present in European and international research groups, the technical design is sufficiently mature to allow for an early start of detector realization.

  18. Characterization and Modeling of a Water-based Liquid Scintillator

    CERN Document Server

    Bignell, Lindsey J; Diwan, Milind V; Hans, Sunej; Jaffe, David E; Kettell, Steven; Rosero, Richard; Themann, Harry W; Viren, Brett; Worcester, Elizabeth; Yeh, Minfang; Zhang, Chao

    2015-01-01

    We have characterised Water-based Liquid Scintillator (WbLS) using low energy protons, UV-VIS absorbance, and fluorescence spectroscopy. We have also developed and validated a simulation model that describes the behaviour of WbLS in our detector configurations for proton beam energies of 2 GeV, 475 MeV, and 210 MeV and for two WbLS compositions. Our results have enabled us to estimate the light yield and ionisation quenching of WbLS, as well as to understand the influence of the wavelength shifting of Cerenkov light on our measurements. These results are relevant to the suitability of water-based liquid scintillator materials for next generation intensity frontier experiments.

  19. Liquid Scintillation Counting - Packard Triple-Label Calibration

    Energy Technology Data Exchange (ETDEWEB)

    Torretto, P. A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-03-23

    The Radiological Measurements Laboratory (RML) maintains and operates nine Packard Liquid Scintillation Counters (LSCs). These counters were obtained through various sources and were generally purchased as 2500, 2700 or 3100 series counters. In 2004/2005 the software and firmware on the counters were upgraded. The counters are now designated as 3100 series counters running the Quantasmart software package. Thus, a single procedure can be used to calibrate and operate the Packard LSCs.

  20. Positronium signature in organic liquid scintillators for neutrino experiments

    CERN Document Server

    Franco, D; Trezzi, D

    2010-01-01

    Electron anti-neutrinos are commonly detected in liquid scintillator experiments via inverse beta decay, by looking at the coincidence between the reaction products, neutron and positron. Prior to positron annihilation, an electron-positron pair may form an orthopositronium (o-Ps) state, with a mean life of a few ns. Even if the o-Ps decay is speeded up by spin flip or pick off effects, it may introduce distortions in the photon emission time distribution, crucial for position reconstruction and pulse shape discrimination algorithms in anti-neutrino experiments. Reversing the problem, the o-Ps induced time distortion represents a new signature for tagging anti-neutrinos in liquid scintillator. In this paper, we report the results of measurements of the o-Ps formation probability and lifetime, for the most used solvents for organic liquid scintillators in neutrino physics (pseudocumene, linear alkyl benzene, phenylxylylethane, and dodecane). We characterize also a mixture of pseudocumene +1.5 g/l of 2,5-diphen...

  1. A Performance Comparison of Nine Selected Liquid Scintillation Cocktails

    Energy Technology Data Exchange (ETDEWEB)

    Verrezen, F.; Loots, H.; Hurtgen, Ch.

    2008-06-15

    In the selection of a suitable liquid scintillation (LSC) cocktail, the primary aspects taken into consideration are overall cocktail performance and specific laboratory needs. Overall performance of 9 selected, commercially available LSC cocktails was assessed by studying parameters of importance for the requirements of the Laboratory for Low Level Radioactivity Measurements of SCK-CEN: sample load capacity, sample compatibility, influence of sample load on counting efficiency, background count rate, figure of merit, quench resistance, sample stability and alpha/beta separation characteristics. The cocktails tested were EcoscintA, Insta Gel Plus, OptiPhase Hisafe3, OptiPhase Trisafe, Ready Gel, SafeScint 1:1, Ultima Gold, Ultima Gold LLT, and Ultima Gold XR. For the data acquisition a Packard TriCarb Model 1900CA and a Quantulus 1220 liquid scintillation counter is used. All samples were prepared in either 20 mL low potassium, borosilicate glass vials or 20 mL high density, polyethylene vials. The aim of this study was to determine a single cocktail that best suits all measurement requirements of the liquid scintillation laboratory at SCK-CEN for the determination of low levels of radioactivity in biological and environmental samples. As a conclusion, Optiphase HiSafe 3 was confirmed to be the optimal cocktail for the laboratory.

  2. A liquid scintillator detector with wavelength-shifting fibre readout

    CERN Document Server

    Doucet, M; Grégoire, G; Panman, J; Zucchelli, P

    2000-01-01

    A technique based on liquid scintillator with wavelength-shiftingfibre readout is interesting for large-mass neutrino detectors.In this paper we present the first results obtained with a laboratoryprototype assembled at CERN. In the configuration tested, a large light yield has been observed and attenuation lengths of the order of 3.2~m have been measured. As a comparison, we also measured the attenuation length of the fibres in air using the same setup. No significant difference in attenuation length between the fibres in air and in liquid was measured.

  3. Organic liquid scintillation detector shape and volume impact on radiation portal monitors

    Science.gov (United States)

    Paff, Marc G.; Clarke, Shaun D.; Pozzi, Sara A.

    2016-07-01

    We have developed and tested a radiation portal monitor using organic liquid scintillation detectors. In order to optimize our system designs, neutron measurements were carried out with three organic liquid scintillation detectors of different shapes and sizes, along with a 3He radiation portal monitor (RPM) as a reference. The three liquids tested were a 7.62 cm diameter by 7.62 cm length cylindrical active volume organic liquid scintillation detector, a 12.7 cm diameter by 12.7 cm length cylindrical active volume organic liquid scintillation detector, and a 25 cm by 25 cm by 10 cm "paddle" shaped organic liquid scintillation detector. Background and Cf-252 neutron measurements were recorded to allow for a comparison of neutron intrinsic efficiencies as well as receiver operating characteristics (ROC) curves between detectors. The 12.7 cm diameter cylindrical active volume organic liquid scintillation detector exhibited the highest intrinsic neutron efficiency (54%) of all three liquid scintillators. An ROC curve analysis for a heavily moderated Cf-252 measurement showed that using the 12.7 cm diameter by 12.7 cm length cylindrical active volume Eljen EJ309 organic liquid scintillation detector would result in the fewest needed detector units in order to achieve a near 100% positive neutron alarm rate while maintaining a better than 1 in 10,000 false alarm rate on natural neutron background. A small number of organic liquid scintillation detectors could therefore be a valid alternative to 3He in some RPM applications.

  4. Detecting energy dependent neutron capture distributions in a liquid scintillator

    Energy Technology Data Exchange (ETDEWEB)

    Balmer, Matthew J.I., E-mail: m.balmer@lancaster.ac.uk [Department of Engineering, Lancaster University, LA1 4YR (United Kingdom); Gamage, Kelum A.A. [Department of Engineering, Lancaster University, LA1 4YR (United Kingdom); Taylor, Graeme C. [Neutron Metrology Group, National Physical Laboratory, Teddington, TW11 0LW (United Kingdom)

    2015-03-11

    A novel technique is being developed to estimate the effective dose of a neutron field based on the distribution of neutron captures in a scintillator. Using Monte Carlo techniques, a number of monoenergetic neutron source energies and locations were modelled and their neutron capture response was recorded. Using back propagation Artificial Neural Networks (ANN) the energy and incident direction of the neutron field was predicted from the distribution of neutron captures within a {sup 6}Li-loaded liquid scintillator. Using this proposed technique, the effective dose of {sup 252}Cf, {sup 241}AmBe and {sup 241}AmLi neutron fields was estimated to within 30% for four perpendicular angles in the horizontal plane. Initial theoretical investigations show that this technique holds some promise for real-time estimation of the effective dose of a neutron field.

  5. The Research Progress of the Liquid Scintillation Detectors on Neutron Measurement

    Institute of Scientific and Technical Information of China (English)

    CHENG; Yi-mei; XU; Xiao-ming; ZHU; Li-qun; BAI; Lei; XU; Zhen; HE; Li-xia; YIN; Hong-he

    2012-01-01

    <正>The research for liquid scintillation detectors on neutron measurement is one of the study objects of technique research on neutron measurement. According to the task requirements, we accomplished the purchase of some detectors and related performance testing. The purchased liquid scintillation detectors BC-501A is produced by Saint-Gobain Company. According to the formulated performance testing outlines for liquid scintillation detectors, we conducted

  6. Simulation and Design of Multi-modulars Detector System of Gadolinium-Loaded Liquid Scintillator

    Institute of Scientific and Technical Information of China (English)

    HOU; Long; WANG; Zhao-hui; YU; Guo-liang; WANG; Qi; KANG; Guo-guo; SU; Xiao-bin; ZHANG; Xiao-peng; ZHANG; Kai

    2012-01-01

    <正>The gadolinium-loaded liquid scintillator has the superiority of high detecting efficiency, and it can be used to measure many kinds of nucleus. We improved this technique and construct a 4π liquid scintillator detecting systems which is composed by many liquid scintillators. By coupling with fission chamber, we form a novel research platform which can be used to measure the (n, 2n) and (n, 3n) cross sections of many nuclei.

  7. Developing Detectors for Scintillation Light in Liquid Argon for DUNE

    Energy Technology Data Exchange (ETDEWEB)

    Howard, Bruce [Fermilab

    2016-12-22

    The Deep Underground Neutrino experiment will conduct a broad program of physics research by studying a beam of neutrinos from Fermilab, atmospheric neutrinos, neutrinos from potential supernovae, and potential nucleon decay events. In pursuit of these studies, the experiment will deploy four 10kt fiducial mass liquid argon time projection chambers underground in Lead, South Dakota. Liquid argon time projection chambers allow high-resolution tracking and energy measurements. A precise timing signal is needed to provide the necessary time stamp to localize events in the drift direction. As liquid argon is a natural scintillator, a photon detection system will be deployed to provide such a signal, especially for non-beam events. In the baseline design for the single-phase time projection chamber, the detectors are contained within the anode plane assemblies. The design of two prototypes utilizing wavelength shifters and light guides are presented, and aspects of the research and development program are discussed.

  8. Scintillation efficiency of nuclear recoil in liquid xenon

    CERN Document Server

    Arneodo, F; Badertscher, A; Benetti, P; Bernardini, E; Bettini, A; Borio di Tigliole, A A; Brunetti, R; Bueno, A G; Calligarich, E; Campanelli, M; Carpanese, C; Cavalli, D; Cavanna, F; Cennini, P; Centro, Sandro; Cesana, A; Cline, D; De Mitri, I; Dolfini, R; Ferrari, A; Gigli-Berzolari, A; Matthey, C; Mauri, F; Mazza, D; Mazzone, L; Meng, G; Montanari, C; Nurzia, G; Otwinowski, S; Palamara, O; Pascoli, D; Pepato, Adriano; Petrera, S; Periale, L; Piano Mortari, G; Piazzoli, A; Picchi, P; Pietropaolo, F; Rancati, T; Rappoldi, A; Raselli, G L; Rebuzzi, D; Revol, Jean Pierre Charles; Rico, J; Rossella, M; Rossi, C; Rubbia, André; Rubbia, Carlo; Sala, P; Scannicchio, D A; Sergiampietri, F; Suzuki, S; Terrani, M; Tian, W; Ventura, Sandro; Vignoli, C; Wang, H; Woo, J; Xu, Z

    2000-01-01

    We present the results of a test done with a Liquid Xenon (LXe) detector for 'Dark Matter' search, exposed to a neutron beam to produce nuclear recoil events simulating those which would be generated by WIMP's elastic scattering. The aim of the experiment was to measure directly the scintillation efficiency of nuclear recoil. The nuclear recoil considered in the test was in the tens of keV range. The ratio of measured visible energy over the true recoil energy was evaluated to be about 20%, in good agreement with the theoretical predictions.

  9. Light propagation in a large volume liquid scintillator

    CERN Document Server

    Alimonti, G; Balata, M; Bellini, G; Benziger, J; Bonetti, S; Caccianiga, B; Cadonati, L; Calaprice, F P; Cecchet, G; Chen, M; Darnton, N; De Bari, A; Deutsch, M; Elisei, F; Feilitzsch, F V; Galbiati, C; Gatti, F; Giammarchi, M G; Giugni, D; Goldbrunner, T; Golubchikov, A; Goretti, A; Hagner, T; Hartmann, F X; Hentig, R V; Heusser, G; Ianni, A; Johnson, M; Laubenstein, M; Lombardi, P; Magni, S; Malvezzi, S; Maneira, J; Manno, I; Manuzio, G; Masetti, F; Mazzucato, U; Meroni, E; Neff, M; Oberauer, L; Perotti, A; Raghavan, R S; Ranucci, G; Resconi, E; Salvo, C; Scardaoni, R; Schönert, S; Smirnov, O; Tartaglia, R; Testera, G; Vogelaar, R B; Vitale, S; Zaimidoroga, O A

    2000-01-01

    The fluorescence light propagation in a large volume detector based on organic liquid scintillators is discussed. In particular, the effects of the fluor radiative transport and solvent Rayleigh scattering are emphasized. These processes have been modelled by a ray-tracing Monte Carlo method and have been experimentally investigated in the Borexino prototype which was a 4.3 ton, 4 pi sensitive detector. The comparison between the model prediction and the experimental data shows a satisfactory agreement indicating that the main aspects of these processes are well understood. Some features of the experimental time response of the detector are still under study.

  10. Optical fiber read-out for liquid argon scintillation light

    CERN Document Server

    Csáthy, J Janicskó; Kratz, J; Schönert, S; Wiesinger, Ch

    2016-01-01

    In this paper we describe the performance of a light detector for Ar scintillation light made of wavelength-shifting (WLS) fibers connected to Silicon-Photomultipliers (SiPM). The setup was conceived to be used as anti-Compton veto for high purity germanium (HPGe) detectors operated directly in liquid Argon (LAr). Background suppression efficiencies for different radioactive sources were measured in a test cryostat with about 800 kg LAr. This work was part of the R\\&D effort for the GERDA experiment.

  11. The efficiency study of different purification methods for liquid scintillator

    CERN Document Server

    Hu, Wei; Yu, Boxiang; Zhang, Xuan; Zhou, Li; Cai, Xiao; Sun, Lijun

    2016-01-01

    JUNO is an experiment aimed at detecting neutrino mass hierarchy. The innermost part of the JUNO detector is formed by 20,000 tons of liquid scintillator which should have very low level of radioactive materials, such as 238U, 232Th, and 40K. Since the radioactive level of raw LAB(the solvent of LS)cannot reach so stringent requirements of JUNO, the purification for LAB plays an extremely important role in LS production. This article studies the efficiency of several different purification methods for LS, like distillation, water extraction and Al2O3 purification.

  12. Liquid Xe scintillation calorimetry and Xe optical properties

    CERN Document Server

    Baldini, A; Cei, F; Doke, T; Grassi, M; Haruyama, T; Mihara, S; Mori, T; Nicolò, D; Nishiguchi, H; Ootani, W; Ozone, K; Papa, A; Pazzi, R; Sawada, R; Sergiampietri, F; Signorelli, G; Suzuki, S; Terasawa, K

    2004-01-01

    The optical properties of LXe in the vacuum ultra violet (VUV), determining the performance of a scintillation calorimeter, are discussed in detail. The available data, measured in a wider spectral region from visible to UV light, and in a large range of Xe densities, from gas to liquid, are examined. It is shown that this information can be used for deriving the LXe optical properties in the VUV. A comparison is made with the few direct measurements in LXe for VUV light resulting from the LXe excitation by ionizing particles. A useful relation is obtained which connects the Rayleigh scattering length to the refractive index in LXe.

  13. Large scale Gd-beta-diketonate based organic liquid scintillator production for antineutrino detection

    CERN Document Server

    Aberle, C; Gramlich, B; Hartmann, F X; Lindner, M; Schönert, S; Schwan, U; Wagner, S; Watanabe, H

    2011-01-01

    Over the course of several decades organic liquid scintillators form the basis for successful neutrino detectors. For electron antineutrino detection at nuclear reactor plants, gadolinium loaded liquid scintillators provide efficient background suppression. In the Double Chooz reactor antineutrino experiment a newly developed gadolinium-loaded scintillator is utilized for the first time. Its large scale production and characterization as well as the creation of an additional metalfree scintillator are presented. Both organic liquids are used in the inner part of the Double Chooz detectors.

  14. Production of Gadolinium-loaded Liquid Scintillator for the Daya Bay Reactor Neutrino Experiment

    CERN Document Server

    Beriguete, Wanda; Ding, Yayun; Hans, Sunej; Heeger, Karsten M; Hu, Liangming; Huang, Aizhong; Luk, Kam-Biu; Nemchenok, Igor; Qi, Ming; Rosero, Richard; Sun, Hansheng; Wang, Ruiguang; Wang, Yifang; Wen, Liangjian; Yang, Yi; Yeh, Minfang; Zhang, Zhiyong; Zhou, Li

    2014-01-01

    We report on the production and characterization of liquid scintillators for the detection of electron antineutrinos by the Daya Bay Reactor Neutrino Experiment. One hundred eighty-five tons of gadolinium-loaded (0.1% by mass) liquid scintillator (Gd-LS) and two hundred tons of unloaded liquid scintillator (LS) were successfully produced from a linear-alkylbenzene (LAB) solvent in six months. The scintillator properties, the production and purification systems, and the quality assurance and control (QA/QC) procedures are described.

  15. Detection of scintillation light in coincidence with ionizing tracks in a liquid argon time projection chamber

    CERN Document Server

    Cennini, P; Rubbia, Carlo; Sergiampietri, F; Bueno, A G; Campanelli, M; Goudsmit, P; Rubbia, André; Periale, L; Suzuki, S; Chen, C; Chen, Y; He, K; Huang, X; Li, Z; Lu, F; Ma, J; Xu, G; Xu, Z; Zhang, C; Zhang, Q; Zheng, S; Cavanna, F; Mazza, D; Piano Mortari, G; Petrera, S; Rossi, C; Mannocchi, G; Picchi, P; Arneodo, F; De Mitri, I; Palamara, O; Cavalli, D; Ferrari, A; Sala, P R; Borio di Tigliole, A A; Cesana, A; Terrani, M; Zavattari, C; Baibusinov, S; Bettini, A; Carpanese, C; Centro, Sandro; Favaretto, D; Pascoli, D; Pepato, Adriano; Pietropaolo, F; Ventura, Sandro; Benetti, P; Calligarich, E; Campo, S; Coco, S; Dolfini, R; Ghedi, B; Gigli-Berzolari, A; Mauri, F; Mazzone, L; Montanari, C; Piazzoli, A; Rappoldi, A; Raselli, G L; Rebuzzi, D; Rossella, M; Scannicchio, D A; Torre, P; Vignoli, C; Cline, D; Otwinowski, S; Wang, H; Woo, J

    1999-01-01

    A system to detect light from liquid argon scintillation has been implemented in a small, ICARUS-like, liquid argon time projection chamber. The system, which uses a VUV-sensitive photomultiplier to collect the light, has recorded many ionizing tracks from cosmic-rays in coincidence with scintillation signals. Our measurements demonstrate that scintillation light detection can provide an effective method for absolute time measurement of events and eventually a useful trigger signal. (19 refs).

  16. Preliminary study of light yield dependence on LAB liquid scintillator composition

    OpenAIRE

    Ye, Xing-Chen; Yu, Bo-Xiang; Zhou, Xiang; Zhao, Li; Ding, Ya-yun; Jie, Quan-lin; Niu, Shun-Li; Liu, Meng-Chao; Ding, Xue-Feng; Zhang, Xuan; Zhou, Li; Fang, Jian; Chen, Hai-tao; HU, Wei; Yan, Jia-qing

    2015-01-01

    Liquid scintillator (LS) will be adopted as the detector material in JUNO (Jiangmen Underground Neutrino Observatory). The energy resolution requirement of JUNO is 3%, which has never previously been reached. To achieve this energy resolution, the light yield of liquid scintillator is an important factor. PPO (the fluor) and bis-MSB (the wavelength shifter) are the two main materials dissolved in LAB. To study the influence of these two materials on the transmission of scintillation photons i...

  17. Light yield measurements in a liquid scintillator detector with wavelength-shifting fibre readout

    CERN Document Server

    Doucet, M; Grégoire, G; Panman, J; Zucchelli, P

    2001-01-01

    A technique based on liquid scintillator with wavelength-shiftingfibre readout is interesting for large-mass neutrino detectors. In this paper, we present results obtained with a laboratoryprototype assembled at CERN. Mixtures made of economical chemicalcomponents were compared to commercial liquid scintillators. Thelight yield was also studied as a function of fibre diameter, fibreposition, and surface quality of the container.

  18. Scintillation light from cosmic-ray muons in liquid argon

    Energy Technology Data Exchange (ETDEWEB)

    Whittington, Denver Wade [Indiana Univ., Bloomington, IN (United States). Physics Dept.; Mufson, S. [Indiana Univ., Bloomington, IN (United States). Astronomy Dept.; Howard, B. [Indiana Univ., Bloomington, IN (United States). Physics Dept.

    2016-05-01

    This paper reports the results of an experiment to directly measure the time-resolved scintillation signal from the passage of cosmic-ray muons through liquid argon. Scintillation light from these muons is of value to studies of weakly-interacting particles in neutrino experiments and dark matter searches. The experiment was carried out at the TallBo dewar facility at Fermilab using prototype light guide detectors and electronics developed for the Deep Underground Neutrino Experiment. Two models are presented for the time structure of the scintillation light, a phenomenological model and a physically-motivated model. Both models find tT = 1:52 ms for the decay time constant of the Ar 2 triplet state. These models also show that the identification of the “early” light fraction in the phenomenological model, FE 25% of the signal, with the total light from singlet decays is an underestimate. The total fraction of singlet light is FS 36%, where the increase over FE is from singlet light emitted by the wavelength shifter through processes with long decay constants. The models were further used to compute the experimental particle identification parameter Fprompt, the fraction of light coming in a short time window after the trigger compared with the light in the total recorded waveform. The models reproduce quite well the typical experimental value 0.3 found by dark matter and double b-decay experiments, which suggests this parameter provides a robust metric for discriminating electrons and muons from more heavily ionizing particles.

  19. Influence of dissolved gas and temperature on the light yield of new liquid scintillators

    CERN Document Server

    Buontempo, S; Golovkin, S V; Martellotti, G; Medvedkov, A M; Penso, G; Soloviev, A S; Vasilchenko, V G

    1999-01-01

    Sixteen new liquid scintillators, emitting green light, were studied. They are based on four solvents combined with four dopants. The influence of different gas atmospheres was studied. In particular it was shown that by keeping these liquid scintillators in vacuum or in a neutral gas, the light yield increases up to 32~\\% at 20 $^{\\circ}$C and for the best solvent-dopant combinations. The dependance of the light yield on temperature was also studied for these scintillators. In the 20--60 $^{\\circ}$C interval, some exhibit a light yield variation of $\\sim$ 3 \\% which is smaller than that of the NE 102A plastic scintillator.

  20. Liquid argon scintillation light studies in LArIAT

    Energy Technology Data Exchange (ETDEWEB)

    Kryczynski, Pawel [Fermilab

    2016-10-12

    The LArIAT experiment is using its Liquid Argon Time Projection Chamber (LArTPC) in the second run of data-taking at the Fermilab Test Beam Facility. The goal of the experiment is to study the response of LArTPCs to charged particles of energies relevant for planned neutrino experiments. In addition, it will help to develop and evaluate the performance of the simulation, analysis, and reconstruction software used in other LAr neutrino experiments. Particles from a tertiary beam detected by LArIAT (mainly protons, pions and muons) are identified using a set of beamline detectors, including Wire Chambers, Time of Flight counters and Cherenkov counters, as well as a simplified sampling detector used to detect muons. In its effort towards augmenting LArTPC technology for other neutrino experiments, LArIAT also takes advantage of the scintillating capabilities of LAr and is testing the possibility of using the light signal to help reconstruct calorimetric information and particle ID. In this report, we present results from these studies of the scintillation light signal to evaluate detector performance and calorimetry.

  1. NEST: A Comprehensive Model for Scintillation Yield in Liquid Xenon

    CERN Document Server

    Szydagis, M; Kazkaz, K; Mock, J; Stolp, D; Sweany, M; Tripathi, M; Uvarov, S; Walsh, N; Woods, M

    2011-01-01

    A comprehensive model for explaining scintillation yield in liquid xenon is introduced. We unify various definitions of work function which abound in the literature and incorporate all available data on electron recoil scintillation yield. This results in a better understanding of electron recoil, and facilitates an improved description of nuclear recoil. An incident gamma energy range of O(1 keV) to O(1 MeV) and electric fields between 0 and O(10 kV/cm) are incorporated into this heuristic model. We show results from a Geant4 implementation, but because the model has a few free parameters, implementation in any simulation package should be simple. We use a quasi-empirical approach, with an objective of improving detector calibrations and performance verification. The model will aid in the design and optimization of future detectors. This model is also easy to extend to other noble elements. In this paper we lay the foundation for an exhaustive simulation code which we call NEST (Noble Element Simulation Tech...

  2. Optimization of screening for radioactivity in urine by liquid scintillation.

    Energy Technology Data Exchange (ETDEWEB)

    Shanks, Sonoya Toyoko; Reese, Robert P.; Preston, Rose T. (Technadyne Engineering Consultants, Inc., Albuquerque, NM)

    2007-08-01

    Numerous events have or could have resulted in the inadvertent uptake of radionuclides by fairly large populations. Should a population receive an uptake, valuable information could be obtained by using liquid scintillation counting (LSC) techniques to quickly screen urine from a sample of the affected population. This study investigates such LSC parameters as discrimination, quench, volume, and count time to yield guidelines for analyzing urine in an emergency situation. Through analyzing variations of the volume and their relationships to the minimum detectable activity (MDA), the optimum ratio of sample size to scintillating chemical cocktail was found to be 1:3. Using this optimum volume size, the alpha MDA varied from 2100 pCi/L for a 30-second count time to 35 pCi/L for a 1000-minute count time. The typical count time used by the Sandia National Laboratories Radiation Protection Sample Diagnostics program is 30 minutes, which yields an alpha MDA of 200 pCi/L. Because MDA is inversely proportional to the square root of the count time, count time can be reduced in an emergency situation to achieve the desired MDA or response time. Note that approximately 25% of the response time is used to prepare the samples and complete the associated paperwork. It was also found that if the nuclide of interest is an unknown, pregenerated discriminator settings and efficiency calibrations can be used to produce an activity value within a factor of two, which is acceptable for a screening method.

  3. Organic liquid scintillation detector shape and volume impact on radiation portal monitors

    Energy Technology Data Exchange (ETDEWEB)

    Paff, Marc G.; Clarke, Shaun D.; Pozzi, Sara A.

    2016-07-21

    We have developed and tested a radiation portal monitor using organic liquid scintillation detectors. In order to optimize our system designs, neutron measurements were carried out with three organic liquid scintillation detectors of different shapes and sizes, along with a {sup 3}He radiation portal monitor (RPM) as a reference. The three liquids tested were a 7.62 cm diameter by 7.62 cm length cylindrical active volume organic liquid scintillation detector, a 12.7 cm diameter by 12.7 cm length cylindrical active volume organic liquid scintillation detector, and a 25 cm by 25 cm by 10 cm “paddle” shaped organic liquid scintillation detector. Background and Cf-252 neutron measurements were recorded to allow for a comparison of neutron intrinsic efficiencies as well as receiver operating characteristics (ROC) curves between detectors. The 12.7 cm diameter cylindrical active volume organic liquid scintillation detector exhibited the highest intrinsic neutron efficiency (54%) of all three liquid scintillators. An ROC curve analysis for a heavily moderated Cf-252 measurement showed that using the 12.7 cm diameter by 12.7 cm length cylindrical active volume Eljen EJ309 organic liquid scintillation detector would result in the fewest needed detector units in order to achieve a near 100% positive neutron alarm rate while maintaining a better than 1 in 10,000 false alarm rate on natural neutron background. A small number of organic liquid scintillation detectors could therefore be a valid alternative to {sup 3}He in some RPM applications.

  4. Aging research of the LAB-based liquid scintillator in stainless steel container

    CERN Document Server

    Chen, Hai-tao; Shan, Qing; Ding, Ya-yun; Du, Bing; Liu, Shu-tong; Zhang, Xuan; Zhou, Li; Jia, Wen-bao; Fang, Jian; Ye, Xing-chen; Hu, Wei; Niu, Shun-li; Yan, Jia-qing; Zhao, Hang; Zhao, Dao-jin

    2014-01-01

    Stainless steel is the material used for the storage vessels and piping systems of LAB-based liquid scintillator in JUNO experiment. Aging is recognized as one of the main degradation mechanisms affecting the properties of liquid scintillator. LAB-based liquid scintillator aging experiments were carried out in different material of containers (type 316 and 304 stainless steel and glass) at two different temperature (40 and 25 degrees Celsius). For the continuous liquid scintillator properties tests, the light yield and the absorption spectrum are nearly the same as that of the unaged one. The attenuation length of the aged samples is 6%~12% shorter than that of the unaged one. But the concentration of element Fe in the LAB-based liquid scintillator does not show a clear change. So the self aging has small effect on liquid scintillator, as well as the stainless steel impurity quenching. Type 316 and 304 stainless steel can be used as LAB-based liquid scintillator vessel, transportation pipeline material.

  5. LArGe. A liquid argon scintillation veto for GERDA

    Energy Technology Data Exchange (ETDEWEB)

    Heisel, Mark

    2011-04-13

    LArGe is a GERDA low-background test facility to study novel background suppression methods in a low-background environment, for possible applications in the GERDA experiment. GERDA searches for the neutrinoless double-beta decay in {sup 76}Ge, by operating naked germanium detectors submersed into 65 m{sup 3} of liquid argon. Similarly, LArGe runs Ge-detectors in 1 m{sup 3} (1.4 tons) of liquid argon, which in addition is instrumented with photomultipliers to detect argon scintillation light. The light is used in anti-coincidence with the germanium detectors, to effectively suppress background events that deposit energy in the liquid argon. This work adresses the design, construction, and commissioning of LArGe. The background suppression efficiency has been studied in combination with a pulse shape discrimination (PSD) technique for various sources, which represent characteristic backgrounds to GERDA. Suppression factors of a few times 10{sup 3} have been achieved. First background data of LArGe (without PSD) yield a background index of (0.12-4.6).10{sup -2} cts/(keV.kg.y) (90% c.l.), which is at the level of the Gerda phase I design goal. Furthermore, for the first time we measure the natural {sup 42}Ar abundance (in parallel to Gerda), and have indication for the 2{nu}{beta}{beta}-decay in natural germanium. (orig.)

  6. Application of scintillating properties of liquid xenon and silicon photomultiplier technology to medical imaging

    Science.gov (United States)

    Gomez-Cadenas, J. J.; Benlloch-Rodriguez, J. M.; Ferrario, Paola

    2016-04-01

    We describe a new positron emission time-of-flight apparatus using liquid xenon. The detector is based in a liquid xenon scintillating cell. The cell shape and dimensions can be optimized depending on the intended application. In its simplest form, the liquid xenon scintillating cell is a box in which two faces are covered by silicon photomultipliers and the others by a reflecting material such as Teflon. It is a compact, homogenous and highly efficient detector which shares many of the desirable properties of monolithic crystals, with the added advantage of high yield and fast scintillation offered by liquid xenon. Our initial studies suggest that good energy and spatial resolution comparable with that achieved by lutetium oxyorthosilicate crystals can be obtained with a detector based in liquid xenon scintillating cells. In addition, the system can potentially achieve an excellent coincidence resolving time of better than 100 ps.

  7. Liquid scintillator composition optimization for use in ultra-high energy cosmic ray detector systems

    Science.gov (United States)

    Beznosko, Dmitriy; Batyrkhanov, Ayan; Iakovlev, Alexander; Yelshibekov, Khalykbek

    2017-06-01

    The Horizon-T (HT) detector system and the currently under R&D HT-KZ detector system are designed for the detection of Extensive Air Showers (EAS) with energies above ˜1016 eV (˜1017 eV for HT-KZ). The main challenges in both detector systems are the fast time resolutions needed for studying the temporary structure of EAS, and the extremely wide dynamic range needed to study the spatial distribution of charged particles in EAS disks. In order to detect the low-density of charged particles far from the EAS axis, a large-area detector is needed. Liquid scintillator with low cost would be a possible solution for such a detector, including the recently developed safe and low-cost water-based liquid scintillators. Liquid organic scintillators give a fast and high light yield (LY) for charged particle detection. It is similar to plastic scintillator in properties but is cost effective for large volumes. With liquid scintillator, one can create detection volumes that are symmetric and yet retain high LY detection. Different wavelength shifters affect the scintillation light by changing the output spectrum into the best detection region. Results of the latest studies of the components optimization in the liquid scintillator formulae are presented.

  8. Discovery potential for supernova relic neutrinos with slow liquid scintillator detectors

    Science.gov (United States)

    Wei, Hanyu; Wang, Zhe; Chen, Shaomin

    2017-06-01

    Detection of supernova relic neutrinos could provide key support for our current understanding of stellar and cosmological evolution, and precise measurements of these neutrinos could yield novel insights into the universe. In this paper, we studied the detection potential of supernova relic neutrinos using linear alkyl benzene (LAB) as a slow liquid scintillator. The linear alkyl benzene features good separation of Cherenkov and scintillation lights, thereby providing a new route for particle identification. We further addressed key issues in current experiments, including (1) the charged current background of atmospheric neutrinos in water Cherenkov detectors and (2) the neutral current background of atmospheric neutrinos in typical liquid scintillator detectors. A kiloton-scale LAB detector at Jinping with O(10) years of data could discover supernova relic neutrinos with a sensitivity comparable to that of large-volume water Cherenkov detectors, typical liquid scintillator detectors, and liquid argon detectors.

  9. Properties of Quantum-Dot-Doped Liquid Scintillators

    Science.gov (United States)

    Coy, Christopher

    2014-03-01

    Novel scintillators based on semiconducting nanocrystals called quantum dots have unique optical and chemical properties that make them interesting for future neutrino experiments especially those searching for neutrino-less double beta decay. In this talk, we report the results of laboratory-scale measurements for three candidate quantum-dot-doped scintillators. We focus on the key properties required for large-scale neutrino experiments, which are the emission spectrum, the attenuation length and the stability. I would like to follow the talk by Andrey Elagin on directionality in scintillators and precede Athena Ierokomos' talk on light yield in scintillators.

  10. Biocomponent determination in vinegars with the help of 14C measured by liquid scintillation counting.

    Science.gov (United States)

    Tudyka, Konrad; Pawlyta, Jacek

    2014-02-15

    This article presents a method of carbon extraction from vinegar used in preparation of liquid scintillation counting cocktails for measurements of low (14)C radioactivity. The presented method is relatively fast and can be used to produce liquid scintillation cocktails e.g., via benzene synthesis. In this work we present specific radiocarbon radioactivity determinations and based on them estimation of bio product content for five commercially available vinegars. All investigated vinegars are likely produced from plants in fermentation process.

  11. The time-of-flight method for characterizing the neutron response of liquid organic scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Iwanowska, J., E-mail: joanna.iwanowska@ncbj.gov.pl [National Centre for Nuclear Research, 05-400 Otwock-Swierk (Poland); Swiderski, L.; Krakowski, T.; Moszynski, M.; Szczesniak, T. [National Centre for Nuclear Research, 05-400 Otwock-Swierk (Poland); Pausch, G. [OncoRay—National Center for Radiation Research in Oncology, Fetscherstr. 74, PF 41, 01307 Dresden (Germany)

    2015-05-01

    The purpose of this work is to present a measurement method for determining the neutron responses of various liquid organic scintillators using a time-of-flight technique in conjunction with a D–T neutron generator. The method is based on fast-neutron scattering on protons in a liquid-scintillator medium and on the acquisition of the neutron response of the medium as a function of the proton-recoil energy. This method can be applied to all scintillators that utilize fast-neutron elastic scattering.

  12. CdZnTe room-temperature semiconductor operation in liquid scintillator

    CERN Document Server

    Stewart, D Y

    2008-01-01

    We demonstrate the first operation of CdZnTe room-temperature detectors in a liquid scintillator environment. This work follows conceptually the Heusser-type detector method of operating HPGe detectors in liquid nitrogen and liquid argon but instead for a far more practical room-temperature ensemble with the aim of achieving ultra-low background levels for radiation detection.

  13. Quenching measurements and modeling of a boron-loaded organic liquid scintillator

    Energy Technology Data Exchange (ETDEWEB)

    Westerdale, S.; Xu, J.; Shields, E.; Froborg, F.; Calaprice, F.; Alexander, T.; Aprahamian, A.; Back, H. O.; Casarella, C.; Fang, X.; Gupta, Y. K.; Lamere, E.; Liu, Q.; Lyons, S.; Smith, M.; Tan, W.

    2017-08-01

    Organic liquid scintillators are used in a wide variety of applications in experimental nuclear and particle physics. Boron-loaded scintillators are particularly useful for detecting neutron captures, due to the high thermal neutron capture cross section of 10B. These scintillators are commonly used in neutron detectors, including the DarkSide-50 neutron veto, where the neutron may produce a signal when it scatters o protons in the scintillator or when it captures on 10B. Reconstructing the energy of these recoils is complicated by scintillation quenching. Understanding how nuclear recoils are quenched in these scintillators is an important and dicult problem. In this article, we present a set of measurements of neutron-induced proton recoils in a boron-loaded organic liquid scintillator at recoil energies ranging from 57-467 keV, and we compare these measurements to predictions from different quenching models. We and that a modified Birks' model whose denominator is quadratic in dE=dx best describes the measurements, with χ2/NDF = 1:6. This result will help model nuclear recoil scintillation in similar detectors and can be used to improve their neutron tagging efficiency.

  14. Quenching Measurements and Modeling of a Boron-Loaded Organic Liquid Scintillator

    Energy Technology Data Exchange (ETDEWEB)

    Westerdale, Shawn [Princeton U.; Xu, Jingke [Princeton U.; Shields, Emily [Princeton U.; Froborg, Francis [Princeton U.; Calaprice, Frank [Princeton U.; Alexander, Thomas [Fermilab; Aprahamian, Ani [Notre Dame U.; Back, Henning O. [Princeton U.; Casarella, Clark [Notre Dame U.; Fang, Xiao [Notre Dame U.; Gupta, Yogesh K. [Notre Dame U.; Lamere, Edward [Notre Dame U.; Liu, Qian [Notre Dame U.; Lyons, Stephanie [Notre Dame U.; Smith, Mallory [Notre Dame U.; Tan, Wanpeng [Notre Dame U.

    2017-03-18

    Organic liquid scintillators are used in a wide variety of applications in experimental nuclear and particle physics. Boron-loaded scintillators are particularly useful for detecting neutron captures, due to the high thermal neutron capture cross section of $^{10}$B. These scintillators are commonly used in neutron detectors, including the DarkSide-50 neutron veto, where the neutron may produce a signal when it scatters off protons in the scintillator or when it captures on $^{10}$B. Reconstructing the energy of these recoils is complicated by scintillation quenching. Understanding how nuclear recoils are quenched in these scintillators is an important and difficult problem. In this article, we present a set of measurements of neutron-induced proton recoils in a boron-loaded organic liquid scintillator at recoil energies ranging from 57--467 keV, and we compare these measurements to predictions from different quenching models. We find that a modified Birks' model whose denominator is quadratic in $dE/dx$ best describes the measurements, with $\\chi^2$/NDF$=1.6$. This result will help model nuclear recoil scintillation in similar detectors and can be used to improve their neutron tagging efficiency.

  15. Development of a low background liquid scintillation counter for a shallow underground laboratory

    CERN Document Server

    Erchinger, J L; Bernacki, B E; Douglas, M; Fuller, E S; Keillor, M E; Morley, S M; Mullen, C A; Orrell, J L; Panisko, M E; Warren, G A; Williams, R O; Wright, M E

    2015-01-01

    Pacific Northwest National Laboratory has recently opened a shallow underground laboratory intended for measurement of low-concentration levels of radioactive isotopes in samples collected from the environment. The development of a low-background liquid scintillation counter is currently underway to further augment the measurement capabilities within this underground laboratory. Liquid scintillation counting is especially useful for measuring charged particle (e.g., $\\beta$, $\\alpha$) emitting isotopes with no (or very weak) gamma-ray yields. The combination of high-efficiency detection of charged particle emission in a liquid scintillation cocktail coupled with the low-background environment of an appropriately-designed shield located in a clean underground laboratory provides the opportunity for increased-sensitivity measurements of a range of isotopes. To take advantage of the 35 meters-water-equivalent overburden of the underground laboratory, a series of simulations have evaluated the scintillation count...

  16. Scintillation yield and time dependence from electronic and nuclear recoils in liquid neon

    CERN Document Server

    Lippincott, W H; Gastler, D; Kearns, E; McKinsey, D N; Nikkel, J A

    2011-01-01

    We have performed measurements of scintillation light in liquid neon, observing a signal yield in our detector as high as (3.5 $\\pm$ 0.4) photoelectrons/keV. We measure pulse shape discrimination efficiency between electronic and nuclear recoils in liquid neon from 50 and 300 keV nuclear recoil energy. We also measure the \\leff\\, parameter in liquid neon between 30 and 370 keV nuclear recoil energy, observing an average \\leff$=0.24$ above 50 keV. We observe a dependence of the scintillation time distribution and signal yield on the pressure and temperature of the liquid neon.

  17. Method for measuring multiple scattering corrections between liquid scintillators

    Science.gov (United States)

    Verbeke, J. M.; Glenn, A. M.; Keefer, G. J.; Wurtz, R. E.

    2016-07-01

    A time-of-flight method is proposed to experimentally quantify the fractions of neutrons scattering between scintillators. An array of scintillators is characterized in terms of crosstalk with this method by measuring a californium source, for different neutron energy thresholds. The spectral information recorded by the scintillators can be used to estimate the fractions of neutrons multiple scattering. With the help of a correction to Feynman's point model theory to account for multiple scattering, these fractions can in turn improve the mass reconstruction of fissile materials under investigation.

  18. Laboratory Studies on the Removal of Radon-Born Lead from KamLAND's Organic Liquid Scintillator

    CERN Document Server

    Keefer, G; Piepke, A; Ebihara, T; Ikeda, H; Kishimoto, Y; Kibe, Y; Koseki, Y; Ogawa, M; Shirai, J; Takeuchi, S; Mauger, C; Zhang, C; Schweitzer, G; Berger, B E; Dazeley, S; Decowski, M P; Detwiler, J A; Djurcic, Z; Dwyer, D A; Efremenko, Y; Enomoto, S; Freedman, S J; Fujikawa, B K; Furuno, K; Gando, A; Gando, Y; Gratta, G; Hatakeyama, S; Heeger, K M; Hsu, L; Ichimura, K; Inoue, K; Iwamoto, T; Kamyshkov, Y; Karwowski, H J; Koga, M; Kozlov, A; Lane, C E; Learned, J G; Maricic, J; Marko, D M; Matsuno, S; McKee, D; McKeown, R D; Miletic, T; Mitsui, T; Motoki, M; Nakajima, K; Nakamura, K; O'Donnell, T; Ogawa, H; Piquemal, F; Ricol, J -S; Shimizu, I; Suekane, F; Suzuki, A; Svoboda, R; Tajima, O; Takemoto, Y; Tamae, K; Tolich, K; Tornow, W; Watanabe, Hideki; Watanabe, Hiroko; Winslow, L A; Yoshida, S

    2013-01-01

    The removal of radioactivity from liquid scintillator has been studied in preparation of a low background phase of KamLAND. This paper describes the methods and techniques developed to measure and efficiently extract radon decay products from liquid scintillator. We report the radio-isotope reduction factors obtained when applying various extraction methods. During this study, distillation was identified as the most efficient method for removing radon daughters from liquid scintillator.

  19. How to observe 8B solar neutrinos in liquid scintillator detectors

    CERN Document Server

    Ianni, A; Villante, F L

    2016-01-01

    We show that liquid organic scintillator detectors (e.g., KamLAND and Borexino) can measure the 8B solar neutrino flux by means of the nu_e charged current interaction with the 13C nuclei naturally contained in the scintillators. The neutrino events can be identified by exploiting the time and space coincidence with the subsequent decay of the produced 13N nuclei. We perform a detailed analysis of the background in KamLAND, Borexino and in a possible liquid scintillator detector at SNOLab, showing that the 8B solar neutrino signal can be extracted with a reasonable uncertainty in a few years of data taking. KamLAND should be able to extract about 18 solar neutrino events from the already collected data. Prospects for gigantic scintillator detectors (such as LENA) are also studied.

  20. Observation of the Dependence of Scintillation from Nuclear Recoils in Liquid Argon on Drift Field

    CERN Document Server

    Alexander, T; Cao, H; Cocco, A G; DeJongh, F; Fiorillo, G; Galbiati, C; Ghag, C; Grandi, L; Kendziora, C; Lippincott, W H; Loer, B; Love, C; Manenti, L; Martoff, C J; Meng, Y; Montanari, D; Mosteiro, P; Olvitt, D; Pordes, S; Qian, H; Rossi, B; Saldanha, R; Tan, W; Tatarowicz, J; Walker, S; Wang, H; Watson, A W; Westerdale, S; Yoo, J

    2013-01-01

    We have exposed a dual-phase Liquid Argon Time Projection Chamber (LAr-TPC) to a low energy pulsed narrowband neutron beam, produced at the Notre Dame Institute for Structure and Nuclear Astrophysics to study the scintillation light yield of recoiling nuclei in a LAr-TPC. A liquid scintillation counter was arranged to detect and identify neutrons scattered in the LAr-TPC target and to select the energy of the recoiling nuclei. We report the observation of a significant dependence on drift field of liquid argon scintillation from nuclear recoils of 11 keV. This observation is important because, to date, estimates of the sensitivity of noble liquid TPC dark matter searches are based on the assumption that electric field has only a small effect on the light yield from nuclear recoils.

  1. Liquid Helium and Liquid Neon - Sensitive, Low Background Scintillation Media For the Detection of Low Energy Neutrinos

    CERN Document Server

    McKinsey, D N

    1999-01-01

    The use of liquid helium and neon as scintillators for neutrino detection is investigated. Several unique properties of these cryogens make them promising candidates for real-time solar neutrino spectroscopy: large ultraviolet scintillation yields from ionizing radiation, transparency to their own scintillation light, and low levels of radioactive impurities. When neutrinos scatter from electrons in liquid helium or neon, ultraviolet light is emitted. The ultraviolet scintillation light can be efficiently converted to the visible with wavelength shifting films. In this way the neutrino-electron scattering events can be detected by photomultiplier tubes at room temperature. We conclude that the solar neutrino flux from the $\\rm p+p\\to e^{+}+d+\

  2. Infrared scintillation yield in gaseous and liquid argon for rare-event experiments

    CERN Document Server

    Buzulutskov, A; Grebenuk, A

    2011-01-01

    The study of primary and secondary scintillations in noble gases and liquids is of paramount importance to rare-event experiments using noble gas media, such those of dark matter search, mu-e-gamma decay search, neutrinoless double-beta decay search and coherent neutrino-nucleus scattering. In the present work, the scintillation yield in gaseous and liquid Ar has for the first time been measured in the near infrared (NIR), both for primary and secondary (proportional) scintillations, using Geiger-mode avalanche photodiodes (G-APDs) and pulsed X-ray irradiation. In the wavelength range of 690-850 nm, the primary NIR-scintillation yield of the fast component was measured to be 17000 photon/MeV in gaseous Ar and 450 photon/MeV in liquid Ar. Proportional NIR scintillations (electroluminescence) in gaseous Ar have been also observed; their amplification parameter at 163 K was measured to be 12 photons per drifting electron per kV. Possible applications of NIR scintillations in high energy physics experiments are d...

  3. A Novel Particle Detector: Quantum Dot Doped Liquid Scintillator

    Science.gov (United States)

    Winslow, Lindley; Conrad, Janet; Jerry, Ruel

    2010-02-01

    Quantum dots are semiconducting nanocrystals. When excited by light shorter then their characteristic wavelength, they re-emit in a narrow band around this wavelength. The size of the quantum is proportional to the characteristic wavelength so they can be tuned for many applications. CdS quantum dots are made in wavelengths from 360nm to 460nm, a perfect range for the sensitivity of photo-multiplier tubes. The synthesis of quantum dots automatically leaves them in toluene, a good organic scintillator and Cd is a particularly interesting material as it has one of the highest thermal neutron cross sections and has several neutrinoless double beta decay and double electron capture isotopes. The performance of quantum dot loaded scintillator compared to standard scintillators is measured and some unique properties presented. )

  4. Measurement of (90)Sr in environmental samples by cation-exchange and liquid scintillation counting.

    Science.gov (United States)

    Amano, H; Yanase, N

    1990-06-01

    A new method for the measurement of (90)Sr in environmental samples by cation-exchange and liquid scintillation counting is described. Strontium carbonate is purified by precipitation and ion-exchange, weighed for the determination of chemical yield, dissolved in hydrochloric acid and mixed with the liquid scintillator, Aquasol-2. Two channels of a low-background liquid scintillation counter are used to determine (90)Sr, (90)Y and (89)Sr, free from the effects of environmental tritium. The values of (90)Sr obtained by this method are in good agreement with those from ordinary (90)Y milking and the gas proportional counting method. The concentration of (90)Sr in the air at Tokai-mura in Japan has been measured by the new method.

  5. Calibration of an EJ309 liquid scintillator using an AmBe neutron source

    Science.gov (United States)

    Bai, Huaiyong; Wang, Zhimin; Zhang, Luyu; Lu, Yi; Jiang, Haoyu; Chen, Jinxiang; Zhang, Guohui

    2017-08-01

    As the light output function of the EJ309 liquid scintillator is nonlinear with respect to the energy of the recoil proton and it is difficult to be predicted, it need to be measured. In the present work, an EJ309 liquid scintillator, 5.1 cm in diameter and 5.1 cm in length, is calibrated with an AmBe neutron source using the time-of-flight method. A Monte Carlo simulation is performed to improve the accuracy of the measured light output function. The obtained light output function is presented and it is compared with existing measurements. The energy resolution of the EJ309 Liquid scintillator is also illustrated.

  6. Timing properties and pulse shape discrimination of LAB-based liquid scintillator

    Institute of Scientific and Technical Information of China (English)

    LI Xiao-Bo; XIAO Hua-Lin; CAO Jun; LI Jin; RUAN Xi-Chao; HENG Yue-Kun

    2011-01-01

    Linear Alkyl Benzene (LAB) is a promising liquid scintillator solvent in neutrino experiments because it has many appealing properties.The timing properties of LAB-based liquid scintillator have been studied through ultraviolet and ionization excitation in this study.The decay time of LAB,PPO and bis-MSB is found to be 48.6 ns,1.55 ns and 1.5 ns,respectively.A model can describe the absorption and re-emission process between PPO and bis-MSB perfectly.The energy transfer time between LAB and PPO with different concentrations can be obtained via another model.We also show that the LAB-based liquid scintillator has good (n,γ) and (α,γ) discrimination power.

  7. Measurement of neutron dose with an organic liquid scintillator coupled with a spectrum weight function

    Energy Technology Data Exchange (ETDEWEB)

    Kim, E.; Endo, A.; Yamaguchi, Y.; Yoshizawa, M.; Nakamura, T.; Shiomi, T

    2002-07-01

    A dose evaluation method for neutrons in the energy range of a few MeV to 100 MeV has been developed using a spectrum weight function (G-function), which is applied to an organic liquid scintillator of 12.7 cm in diameter and 12.7 cm in length. The G-function that converts the pulse height spectrum of the scintillator into the ambient dose equivalent, H*(10), was calculated by an unfolding method using successive approximation of the response function of the scintillator and the ambient dose equivalent per unit neutron fluence (H*(10) conversion coefficients) of ICRP 74. To verify the response function of the scintillator and the value of H*(10) evaluated by the G-function, pulse height spectra of the scintillator were measured in some different neutron fields, which have continuous energy, monoenergetic and quasi-monoenergetic spectra. Values of H*(10) estimated using the G-function and pulse height spectra of the scintillator were compared with those calculated using neutron energy spectra. These doses agreed with each other. From the results, it was concluded that H*(10) can be evaluated directly from the pulse height spectrum of the scintillator by applying the G-function proposed in this study. (author)

  8. Experimental determination of elemental compositions and densities of several common liquid scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez-Barquero, Leonor, E-mail: l.barquero@ciemat.e [Laboratorio de Metrologia de Radiaciones Ionizantes, CIEMAT, Avenida Complutense, 22, 28040 Madrid (Spain); Los Arcos, Jose M., E-mail: jm.losarcos@ciemat.e [Laboratorio de Metrologia de Radiaciones Ionizantes, CIEMAT, Avenida Complutense, 22, 28040 Madrid (Spain)

    2010-07-15

    New accurate data for the density and the elemental composition of several common liquid scintillators have been determined in this work. These data can be used to correctly determine or calculate the counting efficiency of radio-nuclides as well as to evaluate more accurately the uncertainties in LSC measurements due to variability on the composition of scintillators. The discrepancy between nominal densities at 20{sup o}C and the real densities at 20{sup o}C or 16{sup o}C can reach up to 4% among different batches of commercial scintillators all having the same nominal composition. Also significant differences in the elemental composition of commercial cocktails have been found compared to the nominal values. These differences range from 2% up to 260% depending on the element and the scintillator being measured.

  9. Characteristics of Gd-loaded liquid scintillators BC521 and BC525

    Energy Technology Data Exchange (ETDEWEB)

    Banerjee, K. [Variable Energy Cyclotron Centre, 1-AF, Bidhannagar, Kolkata 700 064 (India)], E-mail: kaushik@veccal.ernet.in; Kundu, S.; Mukhopadhyay, S.; Rana, T.K.; Bhattacharya, S.; Bhattacharya, C.; Banerjee, S.R.; Ghosh, T.K.; Mukherjee, G.; Bandyopadhyay, T.; Dey, A.; Meena, J.K.; Mukhopadhyay, P.; Gupta, D.; Pal, S.; Pandit, D. [Variable Energy Cyclotron Centre, 1-AF, Bidhannagar, Kolkata 700 064 (India); Bhattacharya, S. [Department of Physics, Darjeeling Government College, Darjeeling 734 101, West Bengal (India)

    2007-10-11

    Characteristic features of neutron detection properties of the loaded liquid scintillators, i.e., capture time distribution, pulse shape discrimination, and time resolution have been studied for two Gd-loaded liquid scintillators, BC521 and BC525. A new technique to measure the capture time distribution with a small size neutron detector (capacity 7.3 l) in combination with BaF{sub 2} {gamma}-ray detectors has been demonstrated. The measured capture time distributions were in good agreement with the results obtained by Monte Carlo simulation using the computer code DENIS.

  10. Intense vacuum ultraviolet and infrared scintillation of liquid Ar-Xe mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Neumeier, Alexander; Oberauer, Lothar; Potzel, Walter; Roth, Sabine; Schoenert, Stefan [Physik-Department E15, Technische Universitaet Muenchen, James-Franck-Strasse 1, 85748 Garching (Germany); Dandl, Thomas; Heindl, Thomas; Himpsl, Andreas; Wieser, Jochen; Ulrich, Andreas [Physik-Department E12, Technische Universitaet Muenchen, James-Franck-Strasse 1, 85748 Garching (Germany)

    2015-07-01

    Electron-beam excited xenon-doped liquid argon has two intense and well separated scintillation signals in the vacuum ultraviolet (VUV) and in the near-infrared (NIR) wavelength region. Wavelength resolved scintillation spectra of liquid argon-mixtures are presented in a wide wavelength range from 115 to 3500 nm. The most intense emission features in the VUV and the NIR were measured time resolved (ns resolution) under pulsed electron-beam excitation. In this talk, the different detection principles, the results and a possible application in a novel detector concept are briefly discussed.

  11. Liquid scintillators with near infrared emission based on organoboron conjugated polymers.

    Science.gov (United States)

    Tanaka, Kazuo; Yanagida, Takayuki; Yamane, Honami; Hirose, Amane; Yoshii, Ryousuke; Chujo, Yoshiki

    2015-11-15

    The organic liquid scintillators based on the emissive polymers are reported. A series of conjugated polymers containing organoboron complexes which show the luminescence in the near infrared (NIR) region were synthesized. The polymers showed good solubility in common organic solvents. From the comparison of the luminescent properties of the synthesized polymers between optical and radiation excitation, similar emission bands were detected. In addition, less significant degradation was observed. These data propose that the organoboron conjugated polymers are attractive platforms to work as an organic liquid scintillator with the emission in the NIR region.

  12. In-Situ Measurement of Relative Attenuation Length of Gadolinium-Loaded Liquid Scintillator Using Source Data at RENO Experiment

    CERN Document Server

    Kim, H S; Choi, J H; Choi, W Q; Choi, Y; Jang, H I; Jang, J S; Joo, K K; Kim, B R; Kim, J Y; Kim, S B; Kim, W; Kwon, E; Lee, D H; Lim, I T; Pac, M Y; Park, I G; Park, J S; Park, R G; Seo, H; Seo, S H; Seon, Y G; Shin, C D; Yeo, I S; Yu, I

    2016-01-01

    We present an in-situ method of measuring the relative attenuation length of gadolinium-loaded liquid scintillator in the RENO detectors using radioactive source calibration data without requiring any PMT performance model. We observed the degradation of the attenuation length of the gadolinium-loaded liquid scintillator in the RENO detectors by ~50% over a period of about 4 years.

  13. Study of infrared scintillations in gaseous and liquid argon - Part II: light yield and possible applications

    CERN Document Server

    Bondar, A; Dolgov, A; Grebenuk, A; Peleganchuk, S; Shekhtman, V Porosev L; Shemyakina, E; Sokolov, A

    2012-01-01

    We present here a comprehensive study of the light yield of primary and secondary scintillations produced in gaseous and liquid Ar in the near infrared (NIR) and visible region, at cryogenic temperatures. The measurements were performed using Geiger-mode avalanche photodiodes (GAPDs) and pulsed X-ray irradiation. The primary scintillation yield of the fast emission component in gaseous Ar was found to be independent of temperature in the range of 87-160 K; it amounted to 17000+/-3000 photon/MeV in the NIR in the range of 690-1000 nm. In liquid Ar at 87 K, the primary scintillation yield of the fast component was considerably reduced, amounting to 510+/-90 photon/MeV, in the range of 400-1000 nm. Proportional NIR scintillations (electroluminescence) in gaseous Ar were also observed; their amplification parameter at 160 K was measured to be 13 photons per drifting electron per kV. No proportional scintillations were observed in liquid Ar up to the electric fields of 30 kV/cm. The applications of NIR scintillati...

  14. Development of liquid scintillator containing a zirconium complex for neutrinoless double beta decay experiment

    Energy Technology Data Exchange (ETDEWEB)

    Fukuda, Yoshiyuki, E-mail: fukuda@staff.miyakyo-u.ac.jp [Department of Physics, Miyagi University of Education, Sendai, Miyagi 980-0845 (Japan); Moriyama, Shigetaka [Kamioka Observatory, Institute for Cosmic Ray Research, The University of Tokyo, Hida, Gifu 506-1205 (Japan); Ogawa, Izumi [Faculty of Engineering, Fukui University, Fukui-shi, Fukui 910-8507 (Japan)

    2013-12-21

    An organic liquid scintillator containing a zirconium complex has been developed for a new neutrinoless double beta decay experiment. In order to produce a detector that has good energy resolution (4% at 2.5 MeV) and low background (0.1counts/(t·year)) and that can monitor tons of target isotope, we chose a zirconium β-diketone complex having high solubility (over 10 wt%) in anisole. However, the absorption peak of the diketone ligand overlaps with the luminescence of anisole. Therefore, the light yield of the liquid scintillator decreases in proportion to the concentration of the complex. To avoid this problem, we synthesized a β-keto ester complex introducing –OC{sub 3}H{sub 7} or –OC{sub 2}H{sub 5} substituent groups in the β-diketone ligand, which shifted the absorption peak to around 245 nm, which is shorter than the emission peak of anisole (275 nm). However, the shift of the absorption peak depends on the polarity of the scintillation solvent. Therefore we must choose a low polarity solvent for the liquid scintillator. We also synthesized a Zr–ODZ complex, which has a high quantum yield (30%) and good emission wavelength (425 nm) with a solubility 5 wt% in benzonitrile. However, the absorption peak of the Zr–ODZ complex was around 240 nm. Therefore, it is better to use the scintillation solvent which has shorter luminescence wavelength than that of the aromatic solvent.

  15. Temperature dependence of the light yield of the LAB-based and mesitylene-based liquid scintillators

    CERN Document Server

    DongMei, Xia; XiaoBo, Li; XiLei, Sun; YaYun, Ding; Li, Zhou; Jun, Cao; Wei, Hu; XingCheng, Ye; HaiTao, Chen; XueFeng, Ding; Bing, Du

    2014-01-01

    We studied the temperature dependence of the light yield of the linear alkyl benzene (LAB)-based and mesitylene-based liquid scintillators. The light yield increases by 23% for both liquid scintillators when the temperature is lowered from $26\\;^{\\circ}$C to $-40\\;^{\\circ }$C, correcting for the temperature response of the photomultiplier tube. The measurements help to understand the energy response of the liquid scintillator detectors. Especially, the next generation reactor neutrino experiments for neutrino mass hierarchy, such as the Jiangmen Underground Neutrino Observatory (JUNO), require very high energy resolution. As no apparent degradation on the liquid scintillator transparency was observed, lowering the operation temperature of the detector to $\\sim4\\;^\\circ$C will increase the photoelectron yield of the detector by 13%, combining the light yield increase of the liquid scintillator and the quantum efficiency increase of the photomultiplier tubes.

  16. Advanced Scintillator Detector Concept (ASDC): A Concept Paper on the Physics Potential of Water-Based Liquid Scintillator

    CERN Document Server

    Alonso, J R; Bergevin, M; Bernstein, A; Bignell, L; Blucher, E; Calaprice, F; Conrad, J M; Descamps, F B; Diwan, M V; Dwyer, D A; Dye, S T; Elagin, A; Feng, P; Grant, C; Grullon, S; Hans, S; Jaffe, D E; Kettell, S H; Klein, J R; Lande, K; Learned, J G; Luk, K B; Maricic, J; Marleau, P; Mastbaum, A; McDonough, W F; Oberauer, L; Gann, G D Orebi; Rosero, R; Rountree, S D; Sanchez, M C; Shaevitz, M H; Shokair, T M; Smy, M B; Strait, M; Svoboda, R; Tolich, N; Vagins, M R; van Bibber, K A; Viren, B; Vogelaar, R B; Wetstein, M J; Winslow, L; Wonsak, B; Worcester, E T; Wurm, M; Yeh, M; Zhang, C

    2014-01-01

    The recent development of Water-based Liquid Scintillator (WbLS), and the concurrent development of high-efficiency and high-precision-timing light sensors, has opened up the possibility for a new kind of large-scale detector capable of a very broad program of physics. The program would include determination of the neutrino mass hierarchy and observation of CP violation with long-baseline neutrinos, searches for proton decay, ultra-precise solar neutrino measurements, geo- and supernova neutrinos including diff?use supernova antineutrinos, and neutrinoless double beta decay. We outline here the basic requirements of the Advanced Scintillation Detector Concept (ASDC), which combines the use of WbLS, doping with a number of potential isotopes for a range of physics goals, high efficiency and ultra-fast timing photosensors, and a deep underground location. We are considering such a detector at the Long Baseline Neutrino Facility (LBNF) far site, where the ASDC could operate in conjunction with the liquid argon t...

  17. Preliminary study of light yield dependence on LAB liquid scintillator composition

    CERN Document Server

    Ye, Xing-Chen; Zhou, Xiang; Zhao, Li; Ding, Ya-Yun; Jie, Quan-Lin; Niu, Shun-Li; Liu, Meng-Chao; Ding, Xue-Feng; Zhang, Xuan; Zhou, Li; Fang, Jian; Chen, Hai-Tao; Hu, Wei; Yan, Jia-Qing; Zhao, Hang; Hong, Dao-Jin

    2015-01-01

    Liquid scintillator (LS) will be adopted as the detector material in JUNO (Jiangmen Underground Neutrino Observatory). The energy resolution requirement of JUNO is 3%, which has never previously been reached. To achieve this energy resolution, the light yield of liquid scintillator is an important factor. PPO (the fluor) and bis-MSB (the wavelength shifter) are the two main materials dissolved in LAB. To study the influence of these two materials on the transmission of scintillation photons in LS, 25 and 12 cm-long quartz vessels were used in a light yield experiment. LS samples with different concentration of PPO and bis-MSB were tested. At these lengths, the light yield growth is not obvious when the concentration of PPO is higher than 4 g/L. The influence from bis-MSB becomes insignificant when its concentration is higher than 8 mg/L. This result could provide some useful suggestions for the JUNO LS.

  18. Discovery potential for supernova relic neutrinos with slow liquid scintillator detectors

    CERN Document Server

    Wei, Hanyu; Chen, Shaomin

    2016-01-01

    The detection of supernova relic neutrinos would provide a key support for our current understanding of stellar and cosmological evolution, and precise measurements of them would further give us an insight of the profound universe. In this paper we study the potential to detect supernova relic neutrinos using linear alkyl benzene, LAB, as a slow liquid scintillator, which features a good separation of Cherenkov and scintillation lights, thus providing a new ability in particle identification. We also address key issues of current experiments, including 1) the charged current background of atmospheric neutrinos in water Cherenkov detectors, and 2) the neutral current background of atmospheric neutrinos in typical liquid scintillator detectors. With LAB, a kiloton-scale detector, like the SNO, KamLAND, and the future Jinping neutrino detectors, with $\\mathcal{O}$(10) years of data, would have the sensitivity to discover supernova relic neutrinos, which is comparable to large-volume water Cherenkov, typical liqu...

  19. Aqueous liquid scintillation counting with fluor-containing nanosuspensions

    Energy Technology Data Exchange (ETDEWEB)

    Weekley, James C.; Wuenschel, Sara; Rosenstiel, Paul E.; Mumper, Russell J.; Jay, Michael E-mail: jay@email.uky.edu

    2004-06-01

    A microemulsion comprised of water, Brij 78, pentanol and styrene into which PPO and bis-MSB had been dissolved was prepared. Polymerization of the styrene resulted in a suspension of fluor-containing polystyrene nanoparticles (<100 nm). After a concentration step, the aqueous nanosuspension was able to detect {sup 14}C with counting efficiencies over 50% of those of a commercially available scintillation cocktail. Monte Carlo calculations demonstrated that the size and concentration of the nanoparticles were appropriate for optimum detection efficiency.

  20. Alpha and beta particle induced scintillations in liquid and solid neon

    CERN Document Server

    Michniak, R A; McKinsey, D N; Doyle, J M

    2002-01-01

    Scintillations induced by alpha and beta particles in liquid and solid neon are studied and their light yield measured. Charged particle scintillation in neon is primarily in the extreme ultraviolet (EUV). We detect this EUV light by converting it to blue using a wavelength shifting fluor and detecting the blue light with a photomultiplier tube. It is observed that liquid neon is a somewhat less-efficient scintillator than liquid helium for both alpha and beta radiation while the light yield in solid neon is greater than in liquid helium. Based on our measurements of the relative light yields of liquid and solid neon to liquid helium whose absolute light yield has previously been determined, we find that an alpha source in liquid neon produces up to 5900 photons per MeV while a beta source produces up to 7400 photons per MeV. In solid neon, we find that an alpha particle produces up to 9300 photons per MeV while a beta particle produces up to 17,000 photons per MeV. We observe a significant dependence of the ...

  1. Development of a low background liquid scintillation counter for a shallow underground laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Erchinger, Jennifer L.; Aalseth, Craig E.; Bernacki, Bruce E.; Douglas, Matthew; Fuller, Erin S.; Keillor, Martin E.; Morley, Shannon M.; Mullen, Crystal A.; Orrell, John L.; Panisko, Mark E.; Warren, Glen A.; Williams, Russell O.; Wright, Michael E.

    2015-08-20

    Pacific Northwest National Laboratory has recently opened a shallow underground laboratory intended for measurement of lowconcentration levels of radioactive isotopes in samples collected from the environment. The development of a low-background liquid scintillation counter is currently underway to further augment the measurement capabilities within this underground laboratory. Liquid scintillation counting is especially useful for measuring charged particle (e.g., B, a) emitting isotopes with no (orvery weak) gamma-ray yields. The combination of high-efficiency detection of charged particle emission in a liquid scintillation cocktail coupled with the low-background environment of an appropriately-designed shield located in a clean underground laboratory provides the opportunity for increased-sensitivity measurements of a range of isotopes. To take advantage of the 35-meter water-equivalent overburden of the underground laboratory, a series of simulations have evaluated the instrumental shield design requirements to assess the possible background rate achievable. This report presents the design and background evaluation for a shallow underground, low background liquid scintillation counter design for sample measurements.

  2. Effect of low electric fields on alpha scintillation light yield in liquid argon

    Energy Technology Data Exchange (ETDEWEB)

    Agnes, P.; Albuquerque, I. F. M.; Alexander, T.; Alton, A. K.; Asner, D. M.; Back, H. O.; Baldin, B.; Biery, K.; Bocci, V.; Bonfini, G.; Bonivento, W.; Bossa, M.; Bottino, B.; Brigatti, A.; Brodsky, J.; Budano, F.; Bussino, S.; Cadeddu, M.; Cadoni, M.; Calaprice, F.; Canci, N.; Candela, A.; Caravati, M.; Cariello, M.; Carlini, M.; Catalanotti, S.; Cavalcante, P.; Chepurnov, A.; Cicalò, C.; Cocco, A. G.; Covone, G.; D' Angelo, D.; D' Incecco, M.; Davini, S.; Cecco, S. De; Deo, M. De; Vincenzi, M. De; Derbin, A.; Devoto, A.; Eusanio, F. Di; Pietro, G. Di; Dionisi, C.; Edkins, E.; Empl, A.; Fan, A.; Fiorillo, G.; Fomenko, K.; Forster, G.; Franco, D.; Gabriele, F.; Galbiati, C.; Giagu, S.; Giganti, C.; Giovanetti, G. K.; Goretti, A. M.; Granato, F.; Gromov, M.; Guan, M.; Guardincerri, Y.; Hackett, B. R.; Herner, K.; Hughes, D.; Humble, P.; Hungerford, E. V.; Ianni, A.; James, I.; Johnson, T. N.; Jollet, C.; Keeter, K.; Kendziora, C. L.; Koh, G.; Korablev, D.; Korga, G.; Kubankin, A.; Li, X.; Lissia, M.; Loer, B.; Lombardi, P.; Longo, G.; Ma, Y.; Machulin, I. N.; Mandarano, A.; Mari, S. M.; Maricic, J.; Marini, L.; Martoff, C. J.; Meregaglia, A.; Meyers, P. D.; Milincic, R.; Miller, J. D.; Montanari, D.; Monte, A.; Mount, B. J.; Muratova, V. N.; Musico, P.; Napolitano, J.; Agasson, A. Navrer; Odrowski, S.; Oleinik, A.; Orsini, M.; Ortica, F.; Pagani, L.; Pallavicini, M.; Pantic, E.; Parmeggiano, S.; Pelczar, K.; Pelliccia, N.; Pocar, A.; Pordes, S.; Pugachev, D. A.; Qian, H.; Randle, K.; Ranucci, G.; Razeti, M.; Razeto, A.; Reinhold, B.; Renshaw, A. L.; Rescigno, M.; Riffard, Q.; Romani, A.; Rossi, B.; Rossi, N.; Rountree, D.; Sablone, D.; Saggese, P.; Sands, W.; Savarese, C.; Schlitzer, B.; Segreto, E.; Semenov, D. A.; Shields, E.; Singh, P. N.; Skorokhvatov, M. D.; Smirnov, O.; Sotnikov, A.; Stanford, C.; Suvorov, Y.; Tartaglia, R.; Tatarowicz, J.; Testera, G.; Tonazzo, A.; Trinchese, P.; Unzhakov, E. V.; Verducci, M.; Vishneva, A.; Vogelaar, B.; Wada, M.; Walker, S.; Wang, H.; Wang, Y.; Watson, A. W.; Westerdale, S.; Wilhelmi, J.; Wojcik, M. M.; Xiang, X.; Xiao, X.; Xu, J.; Yang, C.; Zhong, W.; Zhu, C.; Zuzel, G.

    2017-01-01

    Measurements were made of scintillation light yield of alpha particles from the $^{222}$Rn decay chain within the DarkSide-50 liquid argon time projection chamber. The light yield was found to increase as the applied electric field increased, with alphas in a 200 V/cm electric field exhibiting a 2% increase in light yield compared to alphas in no field.

  3. Effect of Low Electric Fields on Alpha Scintillation Light Yield in Liquid Argon

    CERN Document Server

    Agnes, P; Alexander, T; Alton, A K; Asner, D M; Back, H O; Baldin, B; Biery, K; Bocci, V; Bonfini, G; Bonivento, W; Bossa, M; Bottino, B; Brigatti, A; Brodsky, J; Budano, F; Bussino, S; Cadeddu, M; Cadoni, M; Calaprice, F; Canci, N; Candela, A; Caravati, M; Cariello, M; Carlini, M; Catalanotti, S; Cavalcante, P; Chepurnov, A; Cicalò, C; Cocco, A G; Covone, G; D'Angelo, D; D'Incecco, M; Davini, S; De Cecco, S; De Deo, M; De Vincenzi, M; Derbin, A; Devoto, A; Di Eusanio, F; Di Pietro, G; Dionisi, C; Edkins, E; Empl, A; Fan, A; Fiorillo, G; Fomenko, K; Forster, G; Franco, D; Gabriele, F; Galbiati, C; Giagu, S; Giganti, C; Giovanetti, G K; Goretti, A M; Granato, F; Gromov, M; Guan, M; Guardincerri, Y; Hackett, B R; Herner, K; Hughes, D; Humble, P; Hungerford, E V; Ianni, A; James, I; Johnson, T N; Jollet, C; Keeter, K; Kendziora, C L; Koh, G; Korablev, D; Korga, G; Kubankin, A; Li, X; Lissia, M; Loer, B; Lombardi, P; Longo, G; Ma, Y; Machulin, I N; Mandarano, A; Mari, S M; Maricic, J; Marini, L; Martoff, C J; Meregaglia, A; Meyers, P D; Milincic, R; Miller, J D; Montanari, D; Monte, A; Mount, B J; Muratova, V N; Musico, P; Napolitano, J; Agasson, A Navrer; Odrowski, S; Oleinik, A; Orsini, M; Ortica, F; Pagani, L; Pallavicini, M; Pantic, E; Parmeggiano, S; Pelczar, K; Pelliccia, N; Pocar, A; Pordes, S; Pugachev, D A; Qian, H; Randle, K; Ranucci, G; Razeti, M; Razeto, A; Reinhold, B; Renshaw, A L; Rescigno, M; Riffard, Q; Romani, A; Rossi, B; Rossi, N; Rountree, D; Sablone, D; Saggese, P; Sands, W; Savarese, C; Schlitzer, B; Segreto, E; Semenov, D A; Shields, E; Singh, P N; Skorokhvatov, M D; Smirnov, O; Sotnikov, A; Stanford, C; Suvorov, Y; Tartaglia, R; Tatarowicz, J; Testera, G; Tonazzo, A; Trinchese, P; Unzhakov, E V; Verducci, M; Vishneva, A; Vogelaar, B; Wada, M; Walker, S; Wang, H; Wang, Y; Watson, A W; Westerdale, S; Wilhelmi, J; Wojcik, M M; Xiang, X; Xiao, X; Xu, J; Yang, C; Zhong, W; Zhu, C; Zuzel, G

    2016-01-01

    Measurements were made of scintillation light yield of alpha particles from the $^{222}$Rn decay chain within the DarkSide-50 liquid argon time projection chamber. The light yield was found to increase as the applied electric field increased, with alphas in a 200 V/cm electric field exhibiting a $\\sim$2% increase in light yield compared to alphas in no field.

  4. Effect of low electric fields on alpha scintillation light yield in liquid argon

    Science.gov (United States)

    Agnes, P.; Albuquerque, I. F. M.; Alexander, T.; Alton, A. K.; Asner, D. M.; Back, H. O.; Baldin, B.; Biery, K.; Bocci, V.; Bonfini, G.; Bonivento, W.; Bossa, M.; Bottino, B.; Brigatti, A.; Brodsky, J.; Budano, F.; Bussino, S.; Cadeddu, M.; Cadoni, M.; Calaprice, F.; Canci, N.; Candela, A.; Caravati, M.; Cariello, M.; Carlini, M.; Catalanotti, S.; Cavalcante, P.; Chepurnov, A.; Cicalò, C.; Cocco, A. G.; Covone, G.; D'Angelo, D.; D'Incecco, M.; Davini, S.; De Cecco, S.; De Deo, M.; De Vincenzi, M.; Derbin, A.; Devoto, A.; Di Eusanio, F.; Di Pietro, G.; Dionisi, C.; Edkins, E.; Empl, A.; Fan, A.; Fiorillo, G.; Fomenko, K.; Forster, G.; Franco, D.; Gabriele, F.; Galbiati, C.; Giagu, S.; Giganti, C.; Giovanetti, G. K.; Goretti, A. M.; Granato, F.; Gromov, M.; Guan, M.; Guardincerri, Y.; Hackett, B. R.; Herner, K.; Hughes, D.; Humble, P.; Hungerford, E. V.; Ianni, A.; James, I.; Johnson, T. N.; Jollet, C.; Keeter, K.; Kendziora, C. L.; Koh, G.; Korablev, D.; Korga, G.; Kubankin, A.; Li, X.; Lissia, M.; Loer, B.; Lombardi, P.; Longo, G.; Ma, Y.; Machulin, I. N.; Mandarano, A.; Mari, S. M.; Maricic, J.; Marini, L.; Martoff, C. J.; Meregaglia, A.; Meyers, P. D.; Milincic, R.; Miller, J. D.; Montanari, D.; Monte, A.; Mount, B. J.; Muratova, V. N.; Musico, P.; Napolitano, J.; Navrer Agasson, A.; Odrowski, S.; Oleinik, A.; Orsini, M.; Ortica, F.; Pagani, L.; Pallavicini, M.; Pantic, E.; Parmeggiano, S.; Pelczar, K.; Pelliccia, N.; Pocar, A.; Pordes, S.; Pugachev, D. A.; Qian, H.; Randle, K.; Ranucci, G.; Razeti, M.; Razeto, A.; Reinhold, B.; Renshaw, A. L.; Rescigno, M.; Riffard, Q.; Romani, A.; Rossi, B.; Rossi, N.; Rountree, D.; Sablone, D.; Saggese, P.; Sands, W.; Savarese, C.; Schlitzer, B.; Segreto, E.; Semenov, D. A.; Shields, E.; Singh, P. N.; Skorokhvatov, M. D.; Smirnov, O.; Sotnikov, A.; Stanford, C.; Suvorov, Y.; Tartaglia, R.; Tatarowicz, J.; Testera, G.; Tonazzo, A.; Trinchese, P.; Unzhakov, E. V.; Verducci, M.; Vishneva, A.; Vogelaar, B.; Wada, M.; Walker, S.; Wang, H.; Wang, Y.; Watson, A. W.; Westerdale, S.; Wilhelmi, J.; Wojcik, M. M.; Xiang, X.; Xiao, X.; Xu, J.; Yang, C.; Zhong, W.; Zhu, C.; Zuzel, G.

    2017-01-01

    Measurements were made of scintillation light yield of alpha particles from the 222Rn decay chain within the DarkSide-50 liquid argon time projection chamber. The light yield was found to increase as the applied electric field increased, with alphas in a 200 V/cm electric field exhibiting a ~2% increase in light yield compared to alphas in no field.

  5. Effect of low electric fields on alpha scintillation light yield in liquid argon

    Energy Technology Data Exchange (ETDEWEB)

    Agnes, P.; Albuquerque, I. F. M.; Alexander, T.; Alton, A. K.; Asner, D. M.; Back, H. O.; Baldin, B.; Biery, K.; Bocci, V.; Bonfini, G.; Bonivento, W.; Bossa, M.; Bottino, B.; Brigatti, A.; Brodsky, J.; Budano, F.; Bussino, S.; Cadeddu, M.; Cadoni, M.; Calaprice, F.; Canci, N.; Candela, A.; Caravati, M.; Cariello, M.; Carlini, M.; Catalanotti, S.; Cavalcante, P.; Chepurnov, A.; Cicalò, C.; Cocco, A. G.; Covone, G.; D' Angelo, D.; D' Incecco, M.; Davini, S.; Cecco, S. De; Deo, M. De; Vincenzi, M. De; Derbin, A.; Devoto, A.; Eusanio, F. Di; Pietro, G. Di; Dionisi, C.; Edkins, E.; Empl, A.; Fan, A.; Fiorillo, G.; Fomenko, K.; Forster, G.; Franco, D.; Gabriele, F.; Galbiati, C.; Giagu, S.; Giganti, C.; Giovanetti, G. K.; Goretti, A. M.; Granato, F.; Gromov, M.; Guan, M.; Guardincerri, Y.; Hackett, B. R.; Herner, K.; Hughes, D.; Humble, P.; Hungerford, E. V.; Ianni, A.; James, I.; Johnson, T. N.; Jollet, C.; Keeter, K.; Kendziora, C. L.; Koh, G.; Korablev, D.; Korga, G.; Kubankin, A.; Li, X.; Lissia, M.; Loer, B.; Lombardi, P.; Longo, G.; Ma, Y.; Machulin, I. N.; Mandarano, A.; Mari, S. M.; Maricic, J.; Marini, L.; Martoff, C. J.; Meregaglia, A.; Meyers, P. D.; Milincic, R.; Miller, J. D.; Montanari, D.; Monte, A.; Mount, B. J.; Muratova, V. N.; Musico, P.; Napolitano, J.; Agasson, A. Navrer; Odrowski, S.; Oleinik, A.; Orsini, M.; Ortica, F.; Pagani, L.; Pallavicini, M.; Pantic, E.; Parmeggiano, S.; Pelczar, K.; Pelliccia, N.; Pocar, A.; Pordes, S.; Pugachev, D. A.; Qian, H.; Randle, K.; Ranucci, G.; Razeti, M.; Razeto, A.; Reinhold, B.; Renshaw, A. L.; Rescigno, M.; Riffard, Q.; Romani, A.; Rossi, B.; Rossi, N.; Rountree, D.; Sablone, D.; Saggese, P.; Sands, W.; Savarese, C.; Schlitzer, B.; Segreto, E.; Semenov, D. A.; Shields, E.; Singh, P. N.; Skorokhvatov, M. D.; Smirnov, O.; Sotnikov, A.; Stanford, C.; Suvorov, Y.; Tartaglia, R.; Tatarowicz, J.; Testera, G.; Tonazzo, A.; Trinchese, P.; Unzhakov, E. V.; Verducci, M.; Vishneva, A.; Vogelaar, B.; Wada, M.; Walker, S.; Wang, H.; Wang, Y.; Watson, A. W.; Westerdale, S.; Wilhelmi, J.; Wojcik, M. M.; Xiang, X.; Xiao, X.; Xu, J.; Yang, C.; Zhong, W.; Zhu, C.; Zuzel, G.

    2017-01-01

    Measurements were made of scintillation light yield of alpha particles from the 222Rn decay chain within the DarkSide-50 liquid argon time projection chamber. The light yield was found to increase as the applied electric field increased, with alphas in a 200 V/cm electric field exhibiting a 2% increase in light yield compared to alphas in no field.

  6. Isotope Fractionation in Methane Reactions Studied by Gas Chromatography and Liquid Scintillation

    DEFF Research Database (Denmark)

    Andersen, Bertel Lohmann; Bidoglio, G.; Leip, A.

    1997-01-01

    Determination of C-14-marked methane by gas chromatography and liquid scintillation counting is shown to be useful in studies of isotope effects. Data on the specific activity is used to separate the contributions of (CH4)-C-14, and (CH4)-C-12 to the gas-chromatographic peak area. As an application...

  7. Novel determination of protein, fat, and lactose of milk by liquid scintillation counter

    Energy Technology Data Exchange (ETDEWEB)

    Noble, R.C.; Shand, J.H.; West, I.G.

    1981-01-01

    A method for routine determination of protein, fat, and lactose contents of milk is based on the ability of a scintillation counter to measure coloration or opalescence through attenuation of photons emitted from sealed miniature carbon-14 and hydrogen-3 radioactive standards. A series of simplified and accurate analytical procedures enable full advantage to be taken of the automatic facilities on the modern liquid scintillation counter. The methods provide several advantages over existing procedures. Accuracy of quantification was high as assessed by comparing the results with those derived by recommended Kjeldahl, Gerber, and colorimetric procedures for protein, fat, and lactose determinations, respectively.

  8. High-resolution tracking using large capillary bundles filled with liquid scintillator

    CERN Document Server

    Annis, P; Benussi, L; Bruski, N; Buontempo, S; Currat, C; D'Ambrosio, N; Van Dantzig, R; Dupraz, J P; Ereditato, A; Fabre, Jean-Paul; Fanti, V; Feyt, J; Frekers, D; Frenkel, A; Galeazzi, F; Garufi, F; Goldberg, J; Golovkin, S V; Gorin, A M; Grégoire, G; Harrison, K; Höpfner, K; Holtz, K; Konijn, J; Kozarenko, E N; Kreslo, I E; Kushnirenko, A E; Liberti, B; Martellotti, G; Medvedkov, A M; Michel, L; Migliozzi, P; Mommaert, C; Mondardini, M R; Panman, J; Penso, G; Petukhov, Yu P; Rondeshagen, D; Siegmund, W P; Tyukov, V E; Van Beek, G; Vasilchenko, V G; Vilain, P; Visschers, J L; Wilquet, G; Winter, Klaus; Wolff, T; Wörtche, H J; Wong, H; Zimyn, K V

    2000-01-01

    We have developed large high-resolution tracking detectors based on glass capillaries filled with organic liquid scintillator of high refractive index. These liquid-core scintillating optical fibres act simultaneously as detectors of charged particles and as image guides. Track images projected onto the readout end of a capillary bundle are visualized by an optoelectronic chain consisting of a set of image-intensifier tubes followed by a photosensitive CCD or by an EBCCD camera. Two prototype detectors, each composed of \\hbox{$\\approx 10^6$} capillaries with \\hbox{20$-$25 $\\mu$m} diameter and \\hbox{0.9$-$1.8 m} length, have been tested, and a spatial resolution of the order of \\hbox{20$-$40 $\\mu$m} has been attained. A high scintillation efficiency and a large light-attenuation length, in excess of 3 m, was achieved through special purification of the liquid scintillator. Along the tracks of minimum-ionizing particles, the hit densities obtained were $\\sim$ 8 hits/mm at the readout window, and \\hbox{$\\sim$ 3 ...

  9. Low-Afterglow, High-Refractive-Index Liquid Scintillators for Fast-Neutron Spectrometry and Imaging Applications

    CERN Document Server

    Lauck, Ronald; Bromberger, Benjamin; Dangendorf, Volker; Goldberg, Mark B; Mor, Ilan; Tittelmeier, Kai; Vartsky, David

    2009-01-01

    For ion and neutron spectrometry and imaging applications at a high intensity pulsed laser facility, fast liquid scintillators with very low afterglow are required. Furthermore, neutron imaging with fiber (or liquid-core) capillary arrays calls for scintillation materials with high refractive index. To this end, we have examined various combinations of established mixtures of fluors and solvents, that were enriched alternatively with nitrogen or oxygen. Dissolved molecular oxygen is known to be a highly effective quenching agent, that efficiently suppresses the population of the triplet states in the fluor, which are primarily responsible for the afterglow. For measuring the glow curves of scintillators, we have employed the time-correlated single photon counting (TCSPC) technique, characterized by high dynamic range of several orders of magnitude in light intensity. In this paper we outline the application for the fast scintillators, briefly present the scintillation mechanism in liquids, describe our specif...

  10. Performance of liquid argon neutrino detectors with enhanced sensitivity to scintillation light

    CERN Document Server

    Sorel, M

    2014-01-01

    Scintillation light is used in liquid argon neutrino detectors to provide a trigger signal, veto information against cosmic rays, and absolute event timing. In this work, we discuss additional opportunities offered by detectors with enhanced sensitivity to scintillation light, that is with light collection efficiencies of about $10^{-3}$. We focus on two key detector performance indicators for neutrino oscillation physics: calorimetric neutrino energy reconstruction and neutrino/antineutrino separation in a non-magnetized detector. Our simulations indicate that a neutrino energy resolution as good as 3.3\\% RMS for 4 GeV electron neutrino charged-current interactions can in principle be obtained in a large detector of this type, by using both charge and light information. By exploiting muon capture in argon and scintillation light information to veto muon decay electrons, we also obtain muon neutrino identification efficiencies of about 50\\%, and muon antineutrino misidentification rates at the few percent lev...

  11. Measurements of Scintillation Efficiency and Pulse-Shape for Low Energy Recoils in Liquid Xenon

    CERN Document Server

    Akimov, D Y; Davidge, D; Dawson, J; Howard, A S; Ivaniouchenkov, Yu; Jones, W G; Joshi, M; Kudryavtsev, V A; Lawson, T B; Lebedenko, V; Lehner, M J; Lightfoot, P K; Liubarsky, I; Lüscher, R; McMillan, J E; Peak, C D; Quenby, J J; Spooner, N J C; Sumner, T J; Tovey, Daniel R; Ward, C K

    2002-01-01

    Results of observations of low energy nuclear and electron recoil events in liquid xenon scintillator detectors are given. The relative scintillation efficiency for nuclear recoils is 0.22 +/- 0.01 in the recoil energy range 40 keV - 70 keV. Under the assumption of a single dominant decay component to the scintillation pulse-shape the log-normal mean parameter T0 of the maximum likelihood estimator of the decay time constant for 6 keV < Eee < 30 keV nuclear recoil events is equal to 21.0 ns +/- 0.5 ns. It is observed that for electron recoils T0 rises slowly with energy, having a value ~ 30 ns at Eee ~ 15 keV. Electron and nuclear recoil pulse-shapes are found to be well fitted by single exponential functions although some evidence is found for a double exponential form for the nuclear recoil pulse-shape.

  12. Rapid determination of gross alpha/beta activity in milk using liquid scintilation counter technique

    Directory of Open Access Journals (Sweden)

    Sas Daniel

    2016-01-01

    Full Text Available Rapid determination of gross alpha and beta emitters in milk by liquid scintillation counter is discussed. This method is based on direct addition of different types of milk into scintillation cocktail and therefore it is very promising for fast determination of alpha/beta activity due to direct alpha and beta separation, measurement in close 4p geometry and without sample treatment. The selected group of radionuclides was chosen with the respect to military significance, radio-toxicity, and possibility of potential misuse. As model radionuclides 241Am, 239Pu, and 90Sr were selected. The Liquid Scintilation Counter Hidex 300 SL equipped with triple-double-coincidence-ratio technique was used for sample measurement. The aim of the work was focused on comparison of different cocktails produced by Hidex and Perkin Elmer, choosing the best cocktail based on our measurement results and adjustment of its appropriate volume. Furthermore, the optimization of ratio between the volume of scintillation cocktail and the volume of urine was investigated with the respect to the model radionuclides. According to the obtained results, the efficiency for alpha emitters was greater than 85% and for beta, greater than 95%. The obtained results allowed this method to be used for rapid determination of gross alpha/beta activity in cases where time is an essence, such as first responders or mass-scale samples, where ordinary means suffer from lack of capacity or simply collapse under the onslaught.

  13. An easy method for Ra-226 determination in river waters by liquid-scintillation counting

    Science.gov (United States)

    Moreno, H. P.; Vioque, I.; Manjón, G.; García-Tenorio, R.

    1999-01-01

    226Ra activity concentration in river water was determined using a low background liquid scintillation counter. Radium was extracted from the samples as Ra-BaSO4 precipitate which, afterwards, was dissolved with EDTA in ammonia medium. Solution was transferred into a low potassium glass vial and then mixed with a scintillation cocktail. Two different scintillation cocktails were selected for comparison. Efficiency, recovery yield and α/β separation were studied with both liquid scintillation cocktails. One single measurement, made one month after radium separation, allows to calculate the226Ra concentration as well as to assess the presence of alpha contamination of the sample. In the case of negligible interferences,224Ra concentrations can be subsequently evaluated in the same sample by the measurement made just after chemical separation of radium. This method has been applied for the determination of226Ra and224Ra activity concentrations in river water collected from different locations along the Odiel river estuary area (South-west of Spain). The presence of chemical industry, the wastes of which are released into the river, could be connected with radium activity concentration enhancements in the water.

  14. Direct activity determination of Mn-54 and Zn-65 by a non-extrapolation liquid scintillation method

    CSIR Research Space (South Africa)

    Simpson, BRS

    2004-02-01

    Full Text Available The measurement of Mn-54 and Zn-65 by liquid scintillation coincidence counting results in low detection efficiencies. The activity obtained from the extrapolation of efficiency data can therefore become problematic if curvature is present...

  15. Fitting of alpha-efficiency versus quenching parameter by exponential functions in liquid scintillation counting

    Energy Technology Data Exchange (ETDEWEB)

    Sosa, M. [Departamento de Ingeniería Física, Campus León, Universidad de Guanajuato, 37150 León, Guanajuato (Mexico); Universidad de Sevilla, Departamento de Física Aplicada II, E.T.S. Arquitectura, Av. Reina Mercedes, 2, 41012 Sevilla (Spain); Manjón, G., E-mail: manjon@us.es [Universidad de Sevilla, Departamento de Física Aplicada II, E.T.S. Arquitectura, Av. Reina Mercedes, 2, 41012 Sevilla (Spain); Mantero, J.; García-Tenorio, R. [Universidad de Sevilla, Departamento de Física Aplicada II, E.T.S. Arquitectura, Av. Reina Mercedes, 2, 41012 Sevilla (Spain)

    2014-05-01

    The objective of this work is to propose an exponential fit for the low alpha-counting efficiency as a function of a sample quenching parameter using a Quantulus liquid scintillation counter. The sample quenching parameter in a Quantulus is the Spectral Quench Parameter of the External Standard (SQP(E)), which is defined as the number of channel under which lies the 99% of Compton spectrum generated by a gamma emitter ({sup 152}Eu). Although in the literature one usually finds a polynomial fitting of the alpha counting efficiency, it is shown here that an exponential function is a better description. - Highlights: • We have studied the quenching in alpha measurement by liquid scintillation counting. • We have reviewed typical fitting of alpha counting efficiency versus quenching parameter. • Exponential fitting of data is proposed as better fitting. • We consider exponential fitting has a physical basis.

  16. Performance of a Large Area Avalanche Photodiode in a Liquid Xenon Ionization and Scintillation Chamber

    CERN Document Server

    Ni, K; Day, D; Giboni, K L; Lopes, J A M; Majewski, P; Yamashita, M

    2005-01-01

    Scintillation light produced in liquid xenon (LXe) by alpha particles, electrons and gamma-rays was detected with a large area avalanche photodiode (LAAPD) immersed in the liquid. The alpha scintillation yield was measured as a function of applied electric field. We estimate the quantum efficiency of the LAAPD to be 45%. The best energy resolution from the light measurement at zero electric field is 7.5%(sigma) for 976 keV internal conversion electrons from Bi-207 and 2.6%(sigma) for 5.5 MeV alpha particles from Am-241. The detector used for these measurements was also operated as a gridded ionization chamber to measure the charge yield. We confirm that using a LAAPD in LXe does not introduce impurities which inhibit the drifting of free electrons.

  17. SNM detection by means of thermal neutron interrogation and a liquid scintillation detector

    Science.gov (United States)

    Ocherashvili, A.; Roesgen, E.; Beck, A.; Caspi, E. N.; Mosconi, M.; Crochemore, J.-M.; Pedersen, B.

    2012-03-01

    The feasibility of using a pulsed neutron generator in a graphite assembly together with a single liquid scintillation detector for the detection of special nuclear materials is investigated. Thermal source neutrons induce fission in fissile material present in the sample. By means of pulse shape discrimination the detector signals from fast fission neutrons are easily identified among the signals from gamma rays and the interrogating thermal neutrons. The method has potential in applications for detection of special nuclear materials in shielded containers.

  18. Solar neutrino interactions with liquid scintillators used for double beta decay experiments

    CERN Document Server

    Ejiri, Hiroyasu

    2016-01-01

    Solar neutrinos interact with double beta decay detectors (DBD) and hence will contribute to backgrounds (BG) for DBD experiments. Background contributions due to solar neutrinos are evaluated for their interactions with atomic electrons and nuclei in liquid scintillation detectors used for DBD experiments. They are shown to be serious backgrounds for high sensitivity DBD experiments to search for the Majorana neutrino masses in the inverted and normal hierarchy regions.

  19. Performance of VUV-sensitive MPPC for liquid argon scintillation light

    Science.gov (United States)

    Igarashi, T.; Tanaka, M.; Washimi, T.; Yorita, K.

    2016-10-01

    A new multi-pixel photon counter (MPPC) sensitive to vacuum ultra-violet (VUV) light (wavelength λ dark count rate of the MPPCs are also evaluated. Using an 241Am α-ray source, the absolute photon detection efficiency (PDE) of the liquid argon (LAr) scintillation light (λ=128 nm) for the latest MPPC model is estimated to be 13%. Based on these basic measurements a possible application of the new MPPC to LAr detectors in dark matter search is suggested.

  20. Efficiency calibration of a liquid scintillation counter for {sup 90}Y Cherenkov counting

    Energy Technology Data Exchange (ETDEWEB)

    Vaca, F. [Huelva Univ. (Spain). Dept. de Fisica Aplicada e Ingenieria Electrica; Manjon, G. [Departamento de Fisica Aplicada, E.T.S. de Arquitectura, Universidad de Sevilla, Av. Reina Mercedes, 2, E-41012 Sevilla (Spain); Garcia-Leon, M. [Departamento de Fisica Atomica, Molecular y Nuclear, Facultad de Fisica, Universidad de Sevilla, Av. Reina Mercedes, s/n. Apartado 1061, E-41080 Sevilla (Spain)

    1998-04-01

    In this paper a complete and self-consistent method for {sup 90}Sr determination in environmental samples is presented. It is based on the Cherenkov counting of {sup 90}Y with a conventional liquid scintillation counter. The effects of color quenching on the counting efficiency and background are carefully studied. A working curve is presented which allows to quantify the correction in the counting efficiency depending on the color quenching strength. (orig.). 6 refs.

  1. Investigation of the scintillation light from liquid argon doped with xenon

    Science.gov (United States)

    Minerskjöld, Maxim; Lindblad, Thomas; Lund-Jensen, Bengt; Székely, Géza

    1993-11-01

    The scintillation light induced by 241Am 5.5 MeV α- particles in liquid argon doped with about 2% xenon detected with a fused silica UV photomultiplier tube is investigated. The pulse-height spectrum, the anode pulse shape and the attenuation of the light output are measured. The latter measurement was the main task of the present investigation and an effective half-length of more than 35 mm was found.

  2. The research program of the Liquid Scintillation Detector (LSD) in the Mont Blanc Laboratory

    Science.gov (United States)

    Dadykin, V. L.; Yakushev, V. F.; Korchagin, P. V.; Korchagin, V. B.; Malgin, A. S.; Ryassny, F. G.; Ryazhskaya, O. G.; Talochkin, V. P.; Zatsepin, G. T.; Badino, G.

    1985-01-01

    A massive (90 tons) liquid scintillation detector (LSD) has been running since October 1984 in the Mont Blanc Laboratory at a depth of 5,200 hg/sq cm of standard rock. The research program of the experiment covers a variety of topics in particle physics and astrophysics. The performance of the detector, the main fields of research are presented and the preliminary results are discussed.

  3. Solar neutrino interactions with liquid scintillators used for double beta-decay experiments

    Science.gov (United States)

    Ejiri, Hiroyasu; Zuber, Kai

    2016-08-01

    Solar neutrinos interact within double-beta-decay (DBD) detectors and hence will contribute to backgrounds (BGs) for DBD experiments. Background contributions due to solar neutrinos are evaluated for their interactions with atomic electrons and nuclei in liquid scintillation detectors used for DBD experiments. They are shown to be serious BGs for high-sensitivity DBD experiments to search for the Majorana neutrino masses in the inverted and normal hierarchy regions.

  4. Development of an Ultra-Low Background Liquid Scintillation Counter for Trace Level Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Erchinger, Jennifer L.; Orrell, John L.; Aalseth, Craig E.; Bernacki, Bruce E.; Douglas, Matthew; Finn, Erin C.; Fuller, Erin S.; Keillor, Martin E.; Morley, Shannon M.; Mullen, Crystal A.; Panisko, Mark E.; Shaff, Sarah M.; Warren, Glen A.; Wright, Michael E.

    2015-09-01

    Low-level liquid scintillation counting (LSC) has been established as one of the radiation detection techniques useful in elucidating environmental processes and environmental monitoring around nuclear facilities. The Ultra-Low Background Liquid Scintillation Counter (ULB-LSC) under construction in the Shallow Underground Laboratory at Pacific Northwest National Laboratory aims to further reduce the MDAs and/or required sample processing. Through layers of passive shielding in conjunction with an active veto and 30 meters water equivalent overburden, the background reduction is expected to be 10 to 100 times below typical analytic low-background liquid scintillation systems. Simulations have shown an expected background of around 14 counts per day. A novel approach to the light collection will use a coated hollow light guide cut into the inner copper shielding. Demonstration LSC measurements will show low-energy detection, spectral deconvolution, and alpha/beta discrimination capabilities, from trials with standards of tritium, strontium-90, and actinium-227, respectively. An overview of the system design and expected demonstration measurements will emphasize the potential applications of the ULB-LSC in environmental monitoring for treaty verification, reach-back sample analysis, and facility inspections.

  5. Design of a Low Background Liquid Scintillation Counter for a Shallow Underground Laboratory

    Science.gov (United States)

    Orrell, John; Aalseth, Craig; Bernacki, Bruce; Douglas, Matt; Erchinger, Jennifer; Fuller, Erin; Keillor, Martin; Morley, Shannon; Mullen, Crystal; Panisko, Mark; Shaff, Sarah; Warren, Glen; Wright, Michael

    2014-09-01

    Pacific Northwest National Laboratory operates a 35-meter water-equivalent overburden, shallow underground laboratory for measuring low-concentration radioactive isotopes in environmental samples collected. A low-background liquid scintillation counter is under development. Liquid scintillation counting is useful for beta-emitting isotopes without (or low) gamma ray yields. The high-efficiency beta detection in a liquid scintillation cocktail coupled with the low-background environment of a shield located in a clean underground laboratory provides for increased-sensitivity measurements to a range of isotopes. Benchmarked simulations have evaluated the shield design requirements to assess the background rate achievable. Assay of shield construction materials provides the basis for the shield design development. The low background design is informed by efforts in experimental design of neutrinoless double beta decay experiments, direct detection dark matter experiments, and low energy neutrino detection experiments. In this vein a background budget for the instrument is presented with attention to low background methods directed toward applications of nuclear measurements.

  6. Measurement of proton quenching factors and PSD-parameters in liquid scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Zimmer, Vincenz; Winter, Juergen; Oberauer, Lothar; Meyer, Judith; Moellenberg, Randolph; Strauss, Raimund; Ciemniak, Christian; Wawoczny, Stephan; Scherzinger, Julius [Technische Universitaet Muenchen, Physik Department E15, Garching (Germany)

    2012-07-01

    In liquid-scintillator detectors like Borexino, Double Chooz and the LENA (Low Energy Neutrino Astronomy) project the inverse beta decay (IBD) is used to detect electron antineutrinos anti {nu}{sub e}. This causes a delayed coincidence signal reducing the background sources to those mimicking such a coincidence. Fast neutrons are one of the background sources by scattering off a proton followed by a capture on hydrogen or gadolinium. Therefore, it is vital to understand the nature of proton recoils in liquid scintillators. Using pulse shape discrimination (PSD) to distinguish the neutron-induced proton recoils from the prompt positron signal from the IBD this background might be reduced. Furthermore, elastic {nu}-p scattering is an important channel for neutrinos from a galactic core-collapse SN. In order to reconstruct the initial neutrino energy, the energy-dependent proton quenching factor has to be known. Therefore, a neutron scattering experiment at the Maier-Leibnitz-Laboratorium in Garching has been set up in order to understand the response of proton recoils in organic liquid scintillators.

  7. The IFIN-HH triple coincidence liquid scintillation counter

    CSIR Research Space (South Africa)

    Razdolescu, AC

    2006-10-01

    Full Text Available at IFIN-HH using a 3 H standard. The performances of the IFIN-HH TDCR counter was checked against the measurement results of the TDCR counters of CSIR NML (South Africa), RC (Poland) and LNHB (France). A set of ready-to-measure Ni-63 sources in liquid...

  8. Scintillation-only Based Pulse Shape Discrimination for Nuclear and Electron Recoils in Liquid Xenon

    CERN Document Server

    Ueshima, K; Hiraide, K; Hirano, S; Kishimoto, Y; Kobayashi, K; Koshio, Y; Liu, J; Martens, K; Moriyama, S; Nakahata, M; Nishiie, H; Ogawa, H; Sekiya, H; Shinozaki, A; Suzuki, Y; Takeda, A; Yamashita, M; Fujii, K; Murayama, I; Nakamura, S; Otsuka, K; Takeuchi, Y; Fukuda, Y; Nishijima, K; Motoki, D; Itow, Y; Masuda, K; Nishitani, Y; Uchida, H; Tasaka, S; Ohsumi, H; Kim, Y D; Kim, Y H; Lee, K B; Lee, M K

    2011-01-01

    In a dedicated test setup at the Kamioka Observatory we studied pulse shape discrimination (PSD) in liquid xenon (LXe) for dark matter searches. PSD in LXe was based on the observation that scintillation light from electron events was emitted over a longer period of time than that of nuclear recoil events, and our method used a simple ratio of early to total scintillation light emission in a single scintillation event. Requiring an efficiency of 50% for nuclear recoil retention we reduced the electron background to 7.7\\pm1.1(stat)\\pm1.2 0.6(sys)\\times10-2 at energies between 4.8 and 7.2 keVee and to 7.7\\pm2.8(stat)\\pm2.5 2.8(sys)\\times10-3 at energies between 9.6 and 12 keVee for a scintillation light yield of 20.9 p.e./keV. Further study was done by masking some of that light to reduce this yield to 4.6 p.e./keV, the same method results in an electron event reduction of 2.4\\pm0.2(stat)\\pm0.3 0.2(sys)\\times10-1 for the lower of the energy regions above. We also observe that in contrast to nuclear recoils the ...

  9. Nuclear recoil scintillation and ionisation yields in liquid xenon from ZEPLIN-III data

    CERN Document Server

    Horn, M; Akimov, D Yu; Araújo, H M; Barnes, E J; Burenkov, A A; Chepel, V; Currie, A; Edwards, B; Ghag, C; Hollingsworth, A; Kalmus, G E; Kobyakin, A S; Kovalenko, A G; Lebedenko, V N; Lindote, A; Lopes, M I; Lüscher, R; Majewski, P; Murphy, A StJ; Neves, F; Paling, S M; da Cunha, J Pinto; Preece, R; Quenby, J J; Reichhart, L; Scovell, P R; Silva, C; Solovov, V N; Smith, N J T; Smith, P F; Stekhanov, V N; Sumner, T J; Thorne, C; de Viveiros, L; Walker, R J

    2011-01-01

    Scintillation and ionisation yields for nuclear recoils in liquid xenon above 10 keVnr (nuclear recoil energy) are deduced from data acquired using broadband Am-Be neutron sources. The nuclear recoil data from several exposures to two sources were compared to detailed simulations. Energy-dependent scintillation and ionisation yields giving acceptable fits to the data were derived. Efficiency and resolution effects are treated using a light collection Monte Carlo, measured photomultiplier response profiles and hardware trigger studies. A gradual fall in scintillation yield below ~40 keVnr is found, together with a rising ionisation yield; both are in good agreement with the latest independent measurements. The analysis method is applied to both the most recent ZEPLIN-III data, acquired with a significantly upgraded detector and a precision-calibrated Am-Be source, as well as to the earlier data from the first run in 2008. A new method for deriving the recoil scintillation yield, which includes sub-threshold S1...

  10. Pulse-shape discrimination of scintillation from alpha and beta particles with liquid scintillator and Geiger-mode multipixel avalanche diodes

    CERN Document Server

    Kreslo, I; Delaquis, S; Ereditato, A; Janos, S; Messina, M; Moser, U; Rossi, B; Zeller, M

    2011-01-01

    A successfull application of Geiger-mode multipixel avalanche diodes (GMAPDs) for pulse-shape discrimination in alpha-beta spectrometry using organic liquid scintillator is described in this paper. Efficient discrimination of alpha and beta components in the emission of radioactive isotopes is achieved for alpha energies above 0.3 MeV. The ultra-compact design of the scintillating detector helps to efficiently suppress cosmic-ray and ambient radiation background. This approach allows construction of hand-held robust devices for monitoring of radioactive contamination in various environmental conditions.

  11. Recent Developments In Fast Neutron Detection And Multiplicity Counting With Verification With Liquid Scintillator

    Energy Technology Data Exchange (ETDEWEB)

    Nakae, L; Chapline, G; Glenn, A; Kerr, P; Kim, K; Ouedraogo, S; Prasad, M; Sheets, S; Snyderman, N; Verbeke, J; Wurtz, R

    2011-09-30

    For many years at LLNL, we have been developing time-correlated neutron detection techniques and algorithms for applications such as Arms Control, Threat Detection and Nuclear Material Assay. Many of our techniques have been developed specifically for the relatively low efficiency (a few percent) attainable by detector systems limited to man-portability. Historically, we used thermal neutron detectors (mainly {sup 3}He), taking advantage of the high thermal neutron interaction cross-sections. More recently, we have been investigating the use of fast neutron detection with liquid scintillators, inorganic crystals, and in the near future, pulse-shape discriminating plastics which respond over 1000 times faster (nanoseconds versus tens of microseconds) than thermal neutron detectors. Fast neutron detection offers considerable advantages, since the inherent nanosecond production time-scales of spontaneous fission and neutron-induced fission are preserved and measured instead of being lost by thermalization required for thermal neutron detectors. We are now applying fast neutron technology to the safeguards regime in the form of fast portable digital electronics as well as faster and less hazardous scintillator formulations. Faster detector response times and sensitivity to neutron momentum show promise for measuring, differentiating, and assaying samples that have modest to very high count rates, as well as mixed fission sources like Cm and Pu. We report on measured results with our existing liquid scintillator array, and progress on the design of a nuclear material assay system that incorporates fast neutron detection, including the surprising result that fast liquid scintillator detectors become competitive and even surpass the precision of {sup 3}He-based counters measuring correlated pairs in modest (kg) samples of plutonium.

  12. Recent Developments in Fast Neutron Detection and Multiplicity Counting with Liquid Scintillator

    Science.gov (United States)

    Nakae, L. F.; Chapline, G. F.; Glenn, A. M.; Kerr, P. L.; Kim, K. S.; Ouedraogo, S. A.; Prasad, M. K.; Sheets, S. A.; Snyderman, N. J.; Verbeke, J. M.; Wurtz, R. E.

    2011-12-01

    For many years, LLNL researchers have been developing time-correlated neutron detection techniques and algorithms for applications such as Arms Control, Threat Detection and Nuclear Material Assay. Many of the techniques have been developed specifically for the relatively low efficiency (a few percent) attainable by detector systems limited to man-portability. Historically, thermal neutron detectors (mainly 3He) were used, taking advantage of the high thermal neutron interaction cross sections. More recently, we have been investigating the use of fast neutron detection with liquid scintillators, inorganic crystals, and in the near future, pulse-shape discriminating plastics that respond over 1000 times faster (ns versus tens of μs) than thermal neutron detectors. Fast neutron detection offers considerable advantages since the inherent ns production timescales of spontaneous fission and neutron-induced fission are preserved and measured instead of being lost by thermalization required for thermal neutron detectors. We are now applying fast neutron technology to the safeguards regime in the form of fast portable digital electronics as well as faster and less hazardous scintillator formulations. Faster detector response times and sensitivity to neutron momentum show promise for measuring, differentiating, and assaying samples that have modest to very high count rates, as well as mixed fission sources like Cm and Pu. We report on measured results with our existing liquid scintillator array and progress on the design of a nuclear material assay system that incorporates fast neutron detection, including the surprising result that fast liquid scintillator detectors become competitive and even surpass the precision of 3He-based counters measuring correlated pairs in modest (kg) samples of plutonium.

  13. Background characterization in a liquid scintillation spectrometer; Caracterizacion del fondo de un espectrometro de centelleo liquido

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Barquero, L.; Los Arcos, J.M.; Jimenez de Mingo, A.

    1995-07-01

    An alternate procedure for background count rate estimation in a liquid scintillation spectrometer is presented, which does not require to measure a blank with similar composition, volume and quench, to the problem sample. The procedure is based on a double linear parameterization which was obtained from a systematic study of the background observed with glass vials, in three different windows, 0 - 20 KeV, 0 - 800 KeV and 0 - 2 MeV, for volume between 2 and 20 mi of three commercial scintillators, Hisafe II, Ultima-Gold and Instagel, and quenching degree in the interval equivalent to 50% - 3% tritium efficiency. This procedure was tested with standard samples of 3H, and led to average discrepancies less than 10% for activity {>=}0,6 Bq, against conventional methods for which the discrepancies are twice on average. (Author) 10 refs.

  14. Determination of {sup 226}Ra and {sup 228}Ra in water by using liquid scintillation spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Mingote, Raquel Maia; Gomes, Nilton Carlos [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil). Servico de Quimica e Radioquimica], E-mail: mingote@cdtn.br; Gomes, Lorena Pedrosa; Menezes, Maria Angela de B.C. [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil). Servico de Reator e Irradiacoes

    2007-07-01

    A procedure for the determination of {sup 226}Ra and {sup 228}Ra in water samples by using liquid scintillation spectrometry was applied. The chemical separation of radium as Ba(Ra)SO{sub 4} was performed by the usual method of coprecipitation with barium carrier. The precipitated was mixed with water, Instagel{sup TM} and Ultima Gold AB{sup TM} scintillation cocktails after the delay time for {sup 226}Ra/{sup 222}Rn radioactive equilibrium. Activities of {sup 226}Ra and {sup 228}Ra were inferred from the alpha and beta counting respectively. It was used the pulse shape analyzer and correction factors for minimizing mutual radiometric interferences. The combined standard uncertainties were evaluated using the law of uncertainty propagation by partial derivatives method. The difficulties of method are discussed. (author)

  15. Occulting Light Concentrators in Liquid Scintillator Neutrino Detectors

    Science.gov (United States)

    Buizza Avanzini, Margherita; Cabrera, Anatael; Dusini, Stefano; Grassi, Marco; He, Miao; Wu, Wenjie

    2017-09-01

    The experimental efforts characterizing the era of precision neutrino physics revolve around collecting high-statistics neutrino samples and attaining an excellent energy and position resolution. Next generation liquid-based neutrino detectors, such as JUNO, HyperKamiokande, etc, share the use of a large target mass, and the need of pushing light collection to the edge for maximal calorimetric information. Achieving high light collection implies considerable costs, especially when considering detector masses of several kt. A traditional strategy to maximize the effective photo-coverage with the minimum number of PMTs relies on Light Concentrators (LC), such as Winston Cones. In this paper, the authors introduce a novel concept called Occulting Light Concentrators (OLC), whereby a traditional LC gets tailored to a conventional PMT, by taking into account its single-photoelectron collection efficiency profile and thus occulting the worst performing portion of the photocathode. Thus, the OLC shape optimization takes into account not only the optical interface of the PMT, but also the maximization of the PMT detection performances. The light collection uniformity across the detector is another advantage of the OLC system. By considering the case of JUNO, we will show OLC capabilities in terms of light collection and energy resolution.

  16. Neutron detection in a high gamma-ray background with EJ-301 and EJ-309 liquid scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Stevanato, L., E-mail: luca.stevanato@pd.infn.it [Dipartimento di Fisica ed Astronomia dell' Universita di Padova, Fisica ' Galileo Galilei' , Via Marzolo 8, I-35131 Padova (Italy); Cester, D. [Dipartimento di Fisica ed Astronomia dell' Universita di Padova, Fisica ' Galileo Galilei' , Via Marzolo 8, I-35131 Padova (Italy); Nebbia, G. [INFN Sezione di Padova, Via Marzolo 8, I-35131 Padova (Italy); Viesti, G. [Dipartimento di Fisica ed Astronomia dell' Universita di Padova, Fisica ' Galileo Galilei' , Via Marzolo 8, I-35131 Padova (Italy)

    2012-10-21

    Using a fast digitizer, the neutron-gamma discrimination capability of the new liquid scintillator EJ-309 is compared with that obtained using standard EJ-301. Moreover the capability of both the scintillation detectors to identify a weak neutron source in a high gamma-ray background is demonstrated. The probability of neutron detection is PD=95% at 95% confidence level for a gamma-ray background corresponding to a dose rate of 100 {mu}Sv/h.

  17. A feasibility study of boron-loaded liquid scintillator for the detection of electron anti-neutrinos

    CERN Document Server

    Wang, S C; Leung, R W S; Wang, S L; Chang, C Y; Chen Chi Ping; Cheng, K C; Ho, T I; Lai, W P; Liu, H M; Mao, Z P; Shih, I C; Wong, H T; Yu, Z Q

    1999-01-01

    Boron-loaded liquid scintillator offers some potential advantages as a detector for electron anti-neutrinos. A research program was carried out with the objective of developing such scintillators. The crucial feature is the pulse shape discrimination properties following the neutron capture by sup 1 sup 0 B. Results of the R and D efforts are presented. The feasibility and the technical difficulties of carrying out a full-scale neutrino experiment based on this approach are discussed. (author)

  18. Relative scintillation efficiency of liquid xenon in the XENON10 direct dark matter search

    Science.gov (United States)

    Manzur, Angel

    There is almost universal agreement that most of the mass in the Universe consists of dark matter. Many lines of reasoning suggest that the dark matter consists of a weakly interactive massive particle (WIMP) with mass ranging from 10 GeV/c 2 to a few TeV/c 2 . Today, numerous experiments aim for direct or indirect dark matter detection. XENON10 is a direct detection experiment using a xenon dual phase time projection chamber. Particles interacting with xenon will create a scintillation signal ( S 1) and ionization. The charge produced is extracted into the gas phase and converted into a proportional scintillation light ( S 2), with an external electric field. The dominant background, b particles and g rays, will undergo an electron recoil (ER) interaction, while WIMPs and neutrons will undergo a nuclear recoil (NR) interaction. Event-by-event discrimination of background signals is based on log 10 ( S 2/ S 1) NR review the requirements for a dark matter search. In particular I discuss the XENON10 detector, deployment, operation, calibrations, analysis and WIMP-nucleon cross- section limits. Finally, I present our latest results for the relative scintillation efficiency ([Special characters omitted.] ) for nuclear recoils in liquid xenon, which was the biggest source of uncertainty in the XENON10 limit. This quantity is essential to determine the nuclear energy scale and to determine the WIMP-nucleon cross sections.

  19. Prompt directional detection of galactic supernova by combining large liquid scintillator neutrino detectors

    CERN Document Server

    Fischer, V; Lasserre, T; Volpe, C; Cribier, M; Durero, M; Gaffiot, J; Houdy, T; Letourneau, A; Mention, G; Pequignot, M; Sibille, V; Vivier, M

    2015-01-01

    Core-collapse supernovae produce an intense burst of electron antineutrinos in the few-tens-of-MeV range. Several Large Liquid Scintillator-based Detectors (LLSD) are currently operated worldwide, being very effective for low energy antineutrino detection through the Inverse Beta Decay (IBD) process. In this article, we develop a procedure for the prompt extraction of the supernova location by revisiting the details of IBD kinematics over the broad energy range of supernova neutrinos. Combining all current scintillator-based detector, we show that one can locate a canonical supernova at 10 kpc with an accuracy of 45 degrees (68% C.L.). After the addition of the next generation of scintillator-based detectors, the accuracy could reach 12 degrees (68% C.L.), therefore reaching the performances of the large water Cerenkov neutrino detectors. We also discuss a possible improvement of the SuperNova Early Warning System (SNEWS) inter-experiment network with the implementation of a directionality information in each...

  20. Measurements of serum glucose using the luciferin/Luciferase system and a liquid scintillation spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Idahl, L.A.; Sandstroem, P.E.; Sehlin, J.

    1986-05-15

    A single-step assay for serum glucose measurements is described. The assay is based on the phosphorylation of D-glucose by glucokinase and the measurement of ATP consumption by firefly luciferase. The luminescence is recorded in an ordinary liquid scintillation spectrometer. The use of stable reagents and a stable final signal (light emission) makes it possible to analyze a large number of samples in each assay run. The assay is of particular value when repeated serum glucose determinations are performed on samples from small laboratory animals.

  1. TDCR and CIEMAT/NIST Liquid Scintillation Methods applied to the Radionuclide Metrology

    Science.gov (United States)

    da Cruz, P. A. L.; da Silva, C. J.; Iwahara, A.; Loureiro, J. S.; De Oliveira, A. E.; Tauhata, L.; Lopes, R. T.

    2016-07-01

    This work presents TDCR and CIEMAT/NIST methods of liquid scintillation implemented in National Institutes of Metrology for activity standardization of radionuclides, which decay by beta emission and electron capture. The computer codes used to calculate the detection efficiency take into account: decay schemes, beta decay theory, quenching parameter evaluation, Poisson statistic model and Monte Carlo simulation for photon and particle interactions in the detection system. Measurements were performed for pure emitters 3H, 14C, 99Tc and for 68Ge/68Ga which decay by electron capture and positron emission, with uncertainties smaller than 1% (k = 1).

  2. TDCR and CIEMAT/NIST liquid scintillation methods applied to the radionuclide metrology

    Energy Technology Data Exchange (ETDEWEB)

    Cruz, Paulo A.L. da; Silva, Carlos J. da; Iwahara, Akira; Loureiro, Jamir S.; Oliveira, Antonio E. de; Tauhata, Luiz, E-mail: palcruz@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Lopes, Ricardo T. [Coordenacao de Programas de Pos-Graduacao de Engenharia (PEN/COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear

    2015-07-01

    In this work are presented TDCR and CIEMAT/NIST methods of liquid scintillation implemented in National Institutes of Metrology for activity standardization of radionuclides which decay by beta emission and electron capture. The computer codes to calculate the detection efficiency take into account: decay schemes, beta decay theory, quenching parameter evaluation, Poisson statistic model and Monte Carlo simulation for photon and particle interactions in the detection system. Measurements were performed for {sup 3}H, {sup 14}C, {sup 99}Tc pure beta emitters in a large energy range, and {sup 68}Ge/{sup 68}Ga which decay by electron capture and positron emission, with uncertainties smaller than 1% (k = 1). (author)

  3. Neutron-gamma discrimination employing pattern recognition of the signal from liquid scintillator

    CERN Document Server

    Kamada, K; Ogawa, S

    1999-01-01

    A pattern recognition method was applied to the neutron-gamma discrimination of the pulses from the liquid scintillator, NE-213. The circuit for the discrimination is composed of A/D converter, fast SCA, memory control circuit, two digital delay lines and two buffer memories. All components are packed on a small circuit board and are installed into a personal computer. Experiments using a weak sup 2 sup 5 sup 2 Cf n-gamma source were undertaken to test the feasibility of the circuit. The circuit is of very easy adjustment and, at the same time, of very economical price when compared with usual discrimination circuits, such as the TAC system.

  4. Discrimination of neutrons and {\\gamma}-rays in liquid scintillator based on Elman neural network

    CERN Document Server

    Zhang, Cai-Xun; Zhao, Jian-Ling; Wang, Li; Yu, Xun-Zhen; Zhu, Jing-Jun; Xing, Hao-Yang

    2015-01-01

    A new neutron and {\\gamma} (n/{\\gamma}) discrimination method based on Elman Neural Network (ENN) was put forward to improve the n/{\\gamma} discrimination performance of liquid scintillator (LS). In this study, neutron and {\\gamma} data acquired from EJ-335 which was exposed in Am-Be radiation field was discriminated using ENN. The difference of n/{\\gamma} discrimination performance between using ENN and Back Propagation Neural Network (BPNN) is that ENN gave a improvement over BPNN in n/{\\gamma} discrimination with the increasing increasing of the Figure of Merit (FOM) from 0.907 to 0.953.

  5. A rope-net support system for the liquid scintillator detector for the SNO+ experiment

    Energy Technology Data Exchange (ETDEWEB)

    Bialek, A., E-mail: abialek@snolab.ca [University of Alberta, Edmonton (Canada); Chen, M. [Queen' s University, Kingston (Canada); Cleveland, B. [SNOLAB, Lively (Canada); Gorel, P.; Hallin, A. [University of Alberta, Edmonton (Canada); Harvey, P.J.; Heise, J. [Queen' s University, Kingston (Canada); Kraus, C. [Laurentian University, Sudbury (Canada); Krauss, C.B. [University of Alberta, Edmonton (Canada); Lawson, I. [SNOLAB, Lively (Canada); Ng, C.J.; Pinkney, B. [University of Alberta, Edmonton (Canada); Rogowsky, D.M. [Rogowsky Engineering Ltd, AECOM Canada Ltd (Canada); Sibley, L.; Soluk, R.; Soukup, J. [University of Alberta, Edmonton (Canada); Vázquez-Jáuregui, E. [SNOLAB, Lively (Canada); Laurentian University, Sudbury (Canada)

    2016-08-11

    The detector for the SNO+ experiment consists of 780 000 kg of liquid scintillator contained in an acrylic vessel that is surrounded by water. A mechanical system has been installed to counteract the 1.25 MN of buoyant force on the acrylic and prevent the vessel from moving. The system is a rope net, designed using a Finite Element Analysis to calculate the amount of stress on the acrylic induced by the ropes, hydrostatic pressures and gravity. A dedicated test was performed to measure strains in the acrylic arising from the complex geometry of the knots in the rope system. The ratio between measured and FEA calculated strains was 1.3.

  6. Data transfer from Beckman LS 5800 liquid scintillation counters to IBM personal computers.

    Science.gov (United States)

    Maan, A C

    1985-09-01

    This communication describes a short routine in BASICA for the IBM-PC, written to collect data from a Beckman liquid scintillation counter. In the form presented here the routine converts incoming bytes into separate lines and saves these lines in a file. There are many possible applications for further use of the data in these files. A few suggestions are given as to the format in which data can be stored and how to process these data automatically after all samples have been counted. The only hardware needed is an asynchronous communications adapter for the IBM-PC and an RS232 cable.

  7. Uncertainty evaluation in tritium activity assay in water by using direct liquid scintillation spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Mingote, Raquel Maia; Rocha, Zildete [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil). Servico de Quimica e Radioquimica]. E-mails: mingote@cdtn.br; rochaz@cdtn.br

    2007-07-01

    Tritium-labeled water is often applied to studies in environmental science, hydrology, biology, oil resources and other research areas. In most cases, the tritium activity is determined by using direct liquid scintillation spectrometry without tritium enrichment. A comprehensive uncertainty quantification is so important as accuracy and precision for analysing the results. This paper presents a discussion about the uncertainty propagation law and the partial derivatives method in the tritium assay. It also includes the relations between the tritium activity results and several input parameters. (author)

  8. Scintillation-only based pulse shape discrimination for nuclear and electron recoils in liquid xenon

    Energy Technology Data Exchange (ETDEWEB)

    Ueshima, K., E-mail: ueshima@suketto.icrr.u-tokyo.ac.jp [Kamioka Observatory, Institute for Cosmic Ray Research, University of Tokyo, Kamioka, Hida, Gifu 506-1205 (Japan); Abe, K.; Hiraide, K.; Hirano, S. [Kamioka Observatory, Institute for Cosmic Ray Research, University of Tokyo, Kamioka, Hida, Gifu 506-1205 (Japan); Kishimoto, Y. [Kamioka Observatory, Institute for Cosmic Ray Research, University of Tokyo, Kamioka, Hida, Gifu 506-1205 (Japan); Institute for the Physics and Mathematics of the Universe, University of Tokyo, Kashiwa, Chiba 277-8582 (Japan); Kobayashi, K.; Koshio, Y. [Kamioka Observatory, Institute for Cosmic Ray Research, University of Tokyo, Kamioka, Hida, Gifu 506-1205 (Japan); Liu, J.; Martens, K. [Institute for the Physics and Mathematics of the Universe, University of Tokyo, Kashiwa, Chiba 277-8582 (Japan); Moriyama, S.; Nakahata, M. [Kamioka Observatory, Institute for Cosmic Ray Research, University of Tokyo, Kamioka, Hida, Gifu 506-1205 (Japan); Institute for the Physics and Mathematics of the Universe, University of Tokyo, Kashiwa, Chiba 277-8582 (Japan); Nishiie, H.; Ogawa, H.; Sekiya, H.; Shinozaki, A. [Kamioka Observatory, Institute for Cosmic Ray Research, University of Tokyo, Kamioka, Hida, Gifu 506-1205 (Japan); Suzuki, Y. [Kamioka Observatory, Institute for Cosmic Ray Research, University of Tokyo, Kamioka, Hida, Gifu 506-1205 (Japan); Institute for the Physics and Mathematics of the Universe, University of Tokyo, Kashiwa, Chiba 277-8582 (Japan); Takeda, A. [Kamioka Observatory, Institute for Cosmic Ray Research, University of Tokyo, Kamioka, Hida, Gifu 506-1205 (Japan); Yamashita, M. [Kamioka Observatory, Institute for Cosmic Ray Research, University of Tokyo, Kamioka, Hida, Gifu 506-1205 (Japan); Institute for the Physics and Mathematics of the Universe, University of Tokyo, Kashiwa, Chiba 277-8582 (Japan); and others

    2011-12-11

    In a dedicated test setup at the Kamioka Observatory we studied pulse shape discrimination (PSD) in liquid xenon (LXe) for dark matter searches in the absence of an externally applied electric field. PSD in LXe was based on the observation that scintillation light from electron events was emitted over a longer period of time than that of nuclear recoil events, and our method used a simple ratio of early to total scintillation light emission in a single scintillation event. Requiring an efficiency of 50% for nuclear recoil retention we reduced the electron background by a factor of 7.7{+-}1.1(stat){+-}{sub 0.6}{sup 1.2}(sys) Multiplication-Sign 10{sup -2} at energies between 4.8 and 7.2 keV{sub ee} and 7.7{+-}2.8(stat){+-}{sub 2.8}{sup 2.5}(sys) Multiplication-Sign 10{sup -3} at energies between 9.6 and 12 keV{sub ee} for a scintillation light yield of 20.9 photoelectrons/keV{sub ee}. Further study was done by masking some of that light to reduce this yield to 4.6 photoelectrons/keV{sub ee}. Under these conditions the same method results in an electron event reduction by a factor of 2.4{+-}0.2(stat){+-}{sub 0.2}{sup 0.3}(sys) Multiplication-Sign 10{sup -1} for the lower of the energy regions above. We also observe that in contrast to nuclear recoils the fluctuations in our early to total ratio for electron events are larger than expected from statistical fluctuations.

  9. Role of quenching on alpha/beta separation in liquid scintillation counting for several high capacity cocktails

    Energy Technology Data Exchange (ETDEWEB)

    Pujol, L.; Sanchez-Cabeza, J.-A. [Universidad Autonoma de Barcelona (Spain). Facultad de Ciencias

    1997-04-01

    The optimization of alpha/beta separation in liquid scintillation using pulse shape analysis is convenient for the simultaneous determination of alpha and beta emitters in natural water and other samples. In this work, alpha/beta separation was studied for different scintillant/vial combinations and it was observed that both the optimum pulse shape discrimination level and the total interference value (that is, the summed relative interference between alpha and beta spectra) were dependent on the sample quenching and independent of the scintillant/vial combination. These results provide a simple method for modifying the counting configuration, such as a change in the cocktail, vial or sample characteristics, without the need to perform exhaustive parameter optimizations. Also, it was observed that, for our counting conditions, the combination of Ultima Gold AB scintillation cocktail with Zinsser low diffusion vials presented the lowest total interference, namely 0.94 {+-} 0.28%, which is insignificant for the counting of environmental samples. (Author).

  10. Evidence of delayed light emission of TetraPhenyl Butadiene excited by liquid Argon scintillation light

    CERN Document Server

    Segreto, Ettore

    2014-01-01

    TetraPhenyl Butadiene is the wavelength shifter most widely used in combination with liquid Argon. The latter emits scintillation photons with a wavelength of 127 nm that need to be downshifted to be detected by photomultipliers with glass or quartz windows. TetraPhenyl Butadiene has been demonstrated to have an extremely high conversion efficiency, possibly higher than 100% for 127 nm photons, while there is no precise information about the time dependence of its emission. It is usually assumed to be exponentially decaying with a characteristic time of the order of one ns, as an extrapolation from measurements with exciting radiation in the near UV. This work shows that TetraPhenyl Butadiene, when excited by 127 nm photons, reemits photons not only with a very short decay time, but also with slower ones due to triplet states de-excitations. This fact can strongly contribute to clarify the anomalies of liquid Argon scintillation light reported in literature since seventies, namely the inconsistency in the mea...

  11. Preparation and performance study of a novel liquid scintillator with mixed solvent as the matrix

    Science.gov (United States)

    Zheng, Zhanlong; Zhu, Jiayi; Luo, Xuan; Xu, Yewei; Zhang, Qianfeng; Zhang, Xing; Bi, Yutie; Zhang, Lin

    2017-04-01

    A novel liquid scintillator with the mixed solvent as the matrix was prepared for obtaining a good comprehensive performance. In this ternary liquid scintillator, the combination of 20% pseudocumene (PC) and 80% linear-alkyl benzene (LAB) by volume was chosen as the mixed solvent, and 2,5-diphenyloxazole (PPO) and 1,4-bis(2-Methylstyryl) benzene (bis-MSB) were as the primary fluor and wavelength shifter, respectively. The optimum prescription was obtained with regard to the light yield. Some characterizations based on the optimal formulation were conducted. The fluorescence emission spectra and wavelength-dependent optical attenuation length of the sample were measured by the fluorescence spectrophotometer and an UV-Vis spectrometer, respectively. The light yield was characterized by adopting the home-made optical platform device. The decay time was tested by adopting the time-correlated single photon counting (TCSPC) technique featured in high dynamic range of several orders of magnitude in light intensity. The experimental test results showed that the sample had a fairly good comprehensive performance.

  12. Performance of VUV-sensitive MPPC for Liquid Argon Scintillation Light

    CERN Document Server

    Igarashi, T; Tanaka, M; Washimi, T; Yorita, K

    2015-01-01

    A new type of the Multi-Pixel Photon Counter (MPPC), sensitive to Vacuum Ultra-Violet (VUV) light (wavelength {\\lambda} < 150 nm), is recently developed and produced by Hamamatsu Photonics K.K. The basic properties of the new MPPC are measured at cryogenic facility of Waseda university using liquid nitrogen. Temperature dependence of breakdown voltage, capacitance, and dark count rate of the MPPC are also evaluated. In addition, the absolute photon detection efficiency (PDE) for liquid argon (LAr) scintillation light ({\\lambda} = 128 nm) is estimated to be about 7% with uncertainty of 2% by using 241 Am {\\alpha}-ray source. Based on these basic measurements a possible application of the new MPPC to LAr detector for dark matter search is discussed.

  13. Liquid scintillators and liquefied rare gases for particle detectors. Background-determination in Double Chooz and scintillation properties of liquid argon

    Energy Technology Data Exchange (ETDEWEB)

    Hofmann, Martin Alexander

    2012-11-27

    }(g)/(g)). Both gamma spectroscopy measurements and the BiPo analysis show the high level of radiopurity reached in Double Chooz. In addition, with the BiPo analysis the {alpha}-quenching factors for the Target and the GammaCatcher liquids have been determined, respectively, to 9.94{+-}0.04 and 13.69{+-}0.02 at 7.7 MeV, and 9.05{+-}0.01 and 14.3{+-}0.1 at 8.8 MeV. The former values show a good agreement with the values obtained in a dedicated laboratory measurement. The time stability of the peak position of the {sup 214}Po {alpha}-peak could be proven, too, showing a stable detector performance at low visible energies. The direct search for Dark Matter can, amongst others, be performed with liquid rare gas detectors, which make use of the scintillation light. However, a good background discrimination is needed. Studies on the wavelength- and time-resolved scintillation properties of liquid argon have therefore been carried out with high resolution and best statistics. The results obtained for different ion beams show that particle discrimination is not feasible in any realistic experiment by means of the wavelength-resolved scintillation light only, but the time structure of the emitted light provides a good handle to distinguish between different incident particles. For heavy ions (sulfur) a ratio of the fast to the slow scintillation component of (1.6 {+-} 0.6) is found, while lighter particles (protons) exhibit a ratio of (0.25 {+-} 0.05). The outcome of the present studies shows that this ratio can also be used in wavelength-integrating measurements which have a comparable detection efficiency for wavelengths below and above {proportional_to}170 nm. The present results demonstrate that for a number of 90 detected photons the singlet-to-triplet distributions obtained for sulfur ions and protons as exciting particles cease to overlap. In a Dark Matter experiment, if all photons produced can be detected, this corresponds to a discrimination threshold of only 2.25 keV.

  14. Nd loaded liquid scintillator to search for 150Nd neutrinoless double beta decay

    Science.gov (United States)

    Barabanov, I.; Bezrukov, L.; Cattadori, C.; Danilov, N.; di Vacri, A.; Ianni, A.; Nisi, S.; Ortica, F.; Romani, A.; Salvo, C.; Smirnov, O.; Yanovich, E.

    2008-11-01

    The 150Nd is considered one of the most attractive candidate for searching neutrinoless double beta (0νββ-) decay, thanks to its high Q-value (3.367 MeV), that makes the external background issue less significative respect to other isotopes, and favorable computed matrix elements. The isotopic abundance of this isotope in natural neodimium is only 5.6% and up to now, it has been investigated only in low mass experiments. The next step is to increase the sensitivity of the experiments using larger mass of neodymium (10 ton-1 kton). This could be possible with a Nd loaded liquid scintillator (LS). At the Gran Sasso National Laboratory (LNGS), a joint INFN (Istituto Nazionale di Fisica Nucleare) and INR (Institute for Nuclear Research of Moscow) working group has been carrying out since 2001 an R&D activity aiming to develop organic liquid scintillators (LS) doped with metals. The achieved know-how and the satisfactory results obtained both with In and Gd allowed to face the development and production of Nd doped LS. The development of metal doped LS is challenging because the metal has to be embedded in a proper organic system that makes it soluble in an organic solvent minimizing the impact of the metal-organic compound on the optical and scintillation properties of the LS. A further challenge in the case of Nd is the presence of absorption bands of this element in the optical region with a transparent region around 400 nm, which is about at the maximum of the scintillator emission spectrum. A 2.5 1 Nd loaded LS has been produced diluting an originally developed Nd-Carboxylic (Nd-CBX) salt in pseudocumene (PC), the solvent of the Borexino liquid scintillator. The measured light yield, at [Nd] = 6.5 g/1 and [PPO] = 1.5 g/1, is ~ 75% of pure PC at the same fluor concentration (~ 10000 ph/MeV). The Nd doped LS has been tested in a 2 1 quartz cell (wrapped by VM2000 reflector film) having dimensions 5x5x100 cm3. The light propagates in the cell by total internal

  15. Combustion water purification techniques influence on OBT analysing using liquid scintillation counting method

    Energy Technology Data Exchange (ETDEWEB)

    Varlam, C.; Vagner, I.; Faurescu, I.; Faurescu, D. [National Institute for Cryogenics and Isotopic Technologies, Valcea (Romania)

    2015-03-15

    In order to determine organically bound tritium (OBT) from environmental samples, these must be converted into water, measurable by liquid scintillation counting (LSC). For this purpose we conducted some experiments to determine OBT level of a grass sample collected from an uncontaminated area. The studied grass sample was combusted in a Parr bomb. However usual interfering phenomena were identified: color or chemical quench, chemiluminescence, overlap over tritium spectrum because of other radionuclides presence as impurities ({sup 14}C from organically compounds, {sup 36}Cl as chloride and free chlorine, {sup 40}K as potassium cations) and emulsion separation. So the purification of the combustion water before scintillation counting appeared to be essential. 5 purification methods were tested: distillation with chemical treatment (Na{sub 2}O{sub 2} and KMnO{sub 4}), lyophilization, chemical treatment (Na{sub 2}O{sub 2} and KMnO{sub 4}) followed by lyophilization, azeotropic distillation with toluene and treatment with a volcanic tuff followed by lyophilization. After the purification step each sample was measured and the OBT measured concentration, together with physico-chemical analysis of the water analyzed, revealed that the most efficient method applied for purification of the combustion water was the method using chemical treatment followed by lyophilization.

  16. Determination of {sup 226}Ra and {sup 224}Ra in sediments samples by liquid scintillation counting

    Energy Technology Data Exchange (ETDEWEB)

    Villa, M. [Facultad de Fisica. Av. Reina Mercedes s/n, apdo 1065, Departamento de Fisica Atomica, Molecular y Nuclear, Universidad de Sevilla, 41080-Sevilla (Spain)]. E-mail: mvilla@us.es; Moreno, H.P. [E.T.S. Arquitectura. Av. Reina Mercedes, 2, Departamento de Fisica Aplicada II, Universidad de Sevilla, 41012-Sevilla (Spain); Manjon, G. [E.T.S. Arquitectura. Av. Reina Mercedes, 2, Departamento de Fisica Aplicada II, Universidad de Sevilla, 41012-Sevilla (Spain)

    2005-10-01

    An experimental procedure has been developed for a rapid determination of the activity concentration of {sup 226}Ra and {sup 224}Ra in sediments by liquid scintillation counting. The importance of the method lies in its application to the measurement of sediments where the Ra-isotopes activity concentration has been increased due to an anthropomorphic enhancement based on releases of naturally occurring radioactive material (NORM). A sample pre-treatment, including a digestion with aqua regia and a precipitation of hydroxides, was applied to samples before the radium extraction, which was made by co-precipitation with barium. Measurements were done in a low background scintillation spectrometer Quantulus 1220, which can separate and detect simultaneously {alpha} and {beta} particles. Additionally, some improvements are suggested for a better {alpha} and {beta} interference correction of the results. The obtaining of radiochemical yields is also improved using {sup 133}Ba as tracer, which decays by emission of conversion electrons and {gamma}-rays; the wide range of radiochemical yields obtained confirms the need of this analyses. The procedure has been applied to the measurement of riverbed sediments from an estuary in the south-west of Spain, affected in the past by direct and indirect phosphogypsum discharges.

  17. Design Constraints for a WIMP Dark Matter and pp Solar Neutrino Liquid Neon Scintillation Detector

    CERN Document Server

    Boulay, M G; Lidgard, J

    2004-01-01

    Detailed Monte-Carlo simulations were used to evaluate the performance of a liquid neon scintillation detector for dark matter and low-energy solar neutrino interactions. A maximum-likelihood event vertex fitter including PMT time information was developed, which significantly improves position resolution over spatial-only algorithms, and substantially decreases the required detector size and achievable analysis energy threshold. The ultimate sensitivity to WIMP dark matter and the pp flux uncertainty are evaluated as a function of detector size. The dependence on the neon scintillation and PMT properties are evaluated. A 300 cm radius detector would allow a ~13 keV threshold, a pp flux uncertainty of ~1%, and limits on the spin-independent WIMP-nucleon cross-section of ~10^{-46} cm^2 for a 100 GeV WIMP, using commercially available PMTs. Detector response calibration and background requirements for a precision pp measurement are defined. Internal radioactivity requirements for uranium, thorium, and krypton a...

  18. Liquid Scintillation Detectors for Gamma and Neutron Diagnostic at Textor and Results of Runaway and Sawtooth Oscillations

    NARCIS (Netherlands)

    Hoenen, F.; Graffmann, E.; Finken, K.H.; Barrenscheen, H. J.; Klein, H.; R. Jaspers,

    1994-01-01

    Time and energy resolved neutron and gamma measurements are performed at the TEXTOR tokamak with a fast liquid NE-213 scintillator. To distinguish between neutron and gamma (gamma)-ray induced events, pulse shape discrimination is used. To suppress scattered radiation, the detector is installed in w

  19. A Measurement of the Absorption of Liquid Argon Scintillation Light by Dissolved Nitrogen at the Part-Per-Million Level

    OpenAIRE

    Jones, B. J. P.; Chiu, C. S.; J. M. Conrad; Ignarra, C. M.; Katori, T.; Toups, M.

    2013-01-01

    We report on a measurement of the absorption length of scintillation light in liquid argon due to dissolved nitrogen at the part-per-million (ppm) level. We inject controlled quantities of nitrogen into a high purity volume of liquid argon and monitor the light yield from an alpha source. The source is placed at different distances from a cryogenic photomultiplier tube assembly. By comparing the light yield from each position we extract the absorption cross section of nitrogen. We find that n...

  20. Determination of {sup 90}SR in food using extraction chromatography and LSC - Liquid Scintillation Counting

    Energy Technology Data Exchange (ETDEWEB)

    Temba, Eliane S.C.; Amaral, Angela M.; Reis Junior, Aluisio S.; Monteiro, Roberto P.G., E-mail: esct@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG/SERTA), Belo Horizonte, MG (Brazil). Servico de Reator e Tecnicas Analiticas

    2013-07-01

    A methodology for the determination of {sup 90}Sr in food is described. The procedure involved a preliminary freeze-drying of the samples followed by dry-ashing and sample digestion. The separation procedure was carried out using extraction chromatography with Sr Resin, from Eichrom, and {sup 90}Sr was measured by liquid scintillation counting (LSC). A certified reference material, IAEA-375, was analyzed in order to evaluate the reliability of the method, and the results showed good agreement between the measured and certified values. The chemical yield was above 90% and the typical counting efficiency was 82%. The calculated limit of detection was 4.8 x 10{sup -3} Bq g{sup -1}. (author)

  1. Discriminating cosmic muons and radioactivity using a liquid scintillation fiber detector

    Science.gov (United States)

    Zhang, Y. P.; Xu, J. L.; Lu, H. Q.; Zhang, P.; Zhang, C. C.; Yang, C. G.

    2017-03-01

    In the case of underground experiments for neutrino physics or rare event searches, the background caused by cosmic muons contributes significantly and therefore must be identified and rejected. We proposed and optimized a new detector using liquid scintillator with wavelenghth-shifting fibers which can be employed as a veto detector for cosmic muons background rejection. From the prototype study, it has been found that the detector has good performances and is capable of discriminating between muons induced signals and environmental radiation background. Its muons detection efficiency is greater than 98%, and on average, 58 photo-electrons (p.e.) are collected when a muon passes through the detector. To optimize the design and enhance the collection of light, the reflectivity of the coating materials has been studied in detail. A Monte Carlo simulation of the detector has been developed and compared to the performed measurements showing a good agreement between data and simulation results.

  2. Discrimination in Liquid Scintillator and Its Usage to Suppress $^{8}$He/$^{9}$Li Backgrounds

    CERN Document Server

    Cheng, Ya-Ping; Zhang, Peng; Cao, Xing-Zhong

    2016-01-01

    Reactor neutrino experiments build large-scale detector systems to trap ghost-like neutrinos. In liquid scintillator, a neutral bound state of a positron and an electron named positronium could be formed. The spin triplet state was called ortho-positronium (o-Ps). In this script, an experiment was designed to measure the lifetime of o-Ps, which turned out to be 3.1 ns. A PSD parameter based on photon emission time distribution (PETD) was constructed to discriminate e$^+$/e$^-$. Finally the application of e$^+$/e$^-$ discrimination in JUNO experiment was shown. It helps suppression of $^{8}$He/$^{9}$Li backgrounds and improves the sensitivity by 0.6 in $\\chi^2$ analysis with assumption of $\\sigma=1$ ns PMT Transit Time Spread, which will bring smearing effect to PETD.

  3. Suppression of gamma-ray sensitivity of liquid scintillators for neutron detection

    Science.gov (United States)

    Swiderski, L.; Moszyński, M.; Wolski, D.; Iwanowska, J.; Szczęśniak, T.; Schotanus, P.; Hurlbut, C.

    2011-10-01

    Methods to reduce gamma-ray sensitivity of a liquid scintillator EJ309 have been studied. Zero-crossing pulse shape discrimination method was used to separate events generated by neutron and gamma radiation between 60- keVee and 4 MeVee. The measurements were carried out under irradiation from an intense 137Cs source, yielding dose rate of 10 mR/h at the detector. A Pu-Be source was used to establish neutron integration window. Pile-up rejection (PUR) circuit was used to reduce gamma-ray induced events under irradiation from an intense gamma-ray source. Further, application of lead, tin and copper shields was done in order to decrease intrinsic gamma-neutron detection efficiency.

  4. Suppression of gamma-ray sensitivity of liquid scintillators for neutron detection

    Energy Technology Data Exchange (ETDEWEB)

    Swiderski, L., E-mail: l.swiderski@ipj.gov.pl [Soltan Institute for Nuclear Studies, PL 05-400 Otwock-Swierk (Poland); Moszynski, M.; Wolski, D.; Iwanowska, J.; Szczesniak, T. [Soltan Institute for Nuclear Studies, PL 05-400 Otwock-Swierk (Poland); Schotanus, P. [Scionix Holland B.V., 3980 CC Bunnik (Netherlands); Hurlbut, C. [Eljen Technology, 2010 E. Broadway, Sweetwater, TX 79556 (United States)

    2011-10-01

    Methods to reduce gamma-ray sensitivity of a liquid scintillator EJ309 have been studied. Zero-crossing pulse shape discrimination method was used to separate events generated by neutron and gamma radiation between 60- keVee and 4 MeVee. The measurements were carried out under irradiation from an intense {sup 137}Cs source, yielding dose rate of 10 mR/h at the detector. A Pu-Be source was used to establish neutron integration window. Pile-up rejection (PUR) circuit was used to reduce gamma-ray induced events under irradiation from an intense gamma-ray source. Further, application of lead, tin and copper shields was done in order to decrease intrinsic gamma-neutron detection efficiency.

  5. ecCNO solar neutrinos: A challenge for gigantic ultra-pure liquid scintillator detectors

    Science.gov (United States)

    Villante, F. L.

    2015-03-01

    Neutrinos produced in the Sun by electron capture reactions on 13N, 15O and 17F, to which we refer as ecCNO neutrinos, are not usually considered in solar neutrino analysis since the expected fluxes are extremely low. The experimental determination of this sub-dominant component of the solar neutrino flux is very difficult but could be rewarding since it provides a determination of the metallic content of the solar core and, moreover, probes the solar neutrino survival probability in the transition region at Eν ∼ 2.5 MeV. In this Letter, we suggest that this difficult measure could be at reach for future gigantic ultra-pure liquid scintillator detectors, such as LENA.

  6. 13C(alpha,n)16O background in a liquid scintillator based neutrino experiment

    CERN Document Server

    Zhao, Jie; Liu, Jianglai; Li, Xiaobo; Zhang, Feihong; Xia, Dongmei

    2013-01-01

    Alpha from natural radioactivity may interact with a nucleus and emit a neutron. The reaction introduces background to the liquid scintillator (LS) based neutrino experiments. In the LS detector, alpha comes from 238U, 232Th and 210Po decay chains. For Gadolinium-doped LS (Gd-LS) detector, alpha also comes from 227Ac. The nucleus 13C is a natural component of Carbon which is rich in the LS. The background rate and spectrum should be subtracted carefully from the neutrino candidates. This paper describes the calculation of neutron yield and spectrum with uncertainty estimated. The results are relevant for many existing neutrino experiments and future LS or Gd-LS based experiments.

  7. Unfolding the fast neutron spectra of a BC501A liquid scintillation detector using GRAVEL method

    CERN Document Server

    Chen, Yonghao; Lei, Jiarong; An, Li; Zhang, Xiaodong; Shao, Jianxiong; Zheng, Pu; Wang, Xinhua

    2013-01-01

    Accurate knowledge of the neutron energy spectra is useful in basic research and applications. The overall procedure of measuring and unfolding the fast neutron energy spectra with BC501A liquid scintillation detector is described. The recoil proton spectrum of Am-Be neutrons was obtained experimentally. With the NRESP7 code, the response matrix of detector was simulated. Combining the recoil proton spectrum and response matrix, the unfolding of neutron spectra was performed by GRAVEL iterative algorithm. A MatLab program based on the GRAVEL method was developed. The continuous neutron spectrum of Am-Be source and monoenergetic neutron spectrum of D-T source have been unfolded successfully and are in good agreement with their standard reference spectra. The unfolded Am-Be spectrum are more accurate than the spectra unfolded by artificial neural networks in recent years.

  8. Unfolding the fast neutron spectra of a BC501A liquid scintillation detector using GRAVEL method

    Science.gov (United States)

    Chen, YongHao; Chen, XiMeng; Lei, JiaRong; An, Li; Zhang, XiaoDong; Shao, JianXiong; Zheng, Pu; Wang, XinHua

    2014-10-01

    Accurate knowledge of the neutron energy spectra is useful in basic research and applications. The overall procedure of measuring and unfolding the fast neutron energy spectra with BC501A liquid scintillation detector is described. The recoil proton spectrum of 241Am-Be neutrons was obtained experimentally. With the NRESP7 code, the response matrix of detector was simulated. Combining the recoil proton spectrum and response matrix, the unfolding of neutron spectra was performed by GRAVEL iterative algorithm. A MatLab program based on the GRAVEL method was developed. The continuous neutron spectrum of 241Am-Be source and monoenergetic neutron spectrum of D-T source have been unfolded successfully and are in good agreement with their standard reference spectra. The unfolded 241Am-Be spectrum are more accurate than the spectra unfolded by artificial neural networks in recent years.

  9. Borexino A real time liquid scintillator detector for low energy solar neutrino study

    CERN Document Server

    Miramonti, L

    2002-01-01

    Borexino is a large unsegmented calorimeter featuring 300 tons of liquid scintillator, contained in a 8.5 meter nylon vessel, viewed by 2200 PMTs. The main goal of Borexino is the study, in real time, of low energy solar neutrinos, and in particular, the monoenergetic neutrinos coming from $^7Be$, which is one of the missing links on the solar neutrino problem. The achievement of high radiopurity level, in the order of $10^{-16} g/g$ of U/Th equivalent, necessary to the detection of the low energy component of the solar neutrino flux, was proved in the Borexino prototype: the Counting Test Facility. The detector is located underground in the Laboratori Nazionali del Gran Sasso in the center of Italy at 3500 meter water equivalent depth. In this paper the science and technology of Borexino are reviewed and its main capabilities are presented.

  10. Application of pulse decay discrimination liquid scintillation counting for indoor radon measurement

    Science.gov (United States)

    Bem, H.; Ostrowska, M.; Bem, E. M.

    1999-01-01

    The pulse decay discrimination (PDD) liquid scintillation technique has been applied to optimise radon counting by the Pico-Rad method. A dermination limit (with 10% relative error) of 4.8 Bqm-3 for indoor radon measurement has been achieved for optimal PDD setting with a radon elution cocktail containing 20% (v/v) of Ultima Gold AB in Instafluor. From a practical point of view this procedure allows a shortening of the counting time to 1 hour after 48 hours exposure to detectors. This method has been applied to indoor radon determinations in 626 places (municipal offices and private dwellings) in the Lódz region. These measureents resulted in an average concentration of 21.4 Bqm-3 and a median value of 15.1 Bqm-3. Analysis of the data indicates that most indoor radon comes from the underlying soil, which contains relatively little226Ra (10-20 Bqkg-1).

  11. Ultra Low Level Tritium Analysis Method Using a Liquid Scintillation Counter

    Energy Technology Data Exchange (ETDEWEB)

    Noh, S. J.; Kim, H. J.; Kim, H.; Lim, H. J.; Lee, M. W.; Jeong, D. H.; Kim, J. K.; Kang, Y. R. [Dongnam Institute of Radiological and Medical Sciences, Busan (Korea, Republic of); Nam, S. H. [Inje University, Gimhae, (Korea, Republic of)

    2015-05-15

    To evaluate {sup 3}H concentration in the atmosphere more accurately compared to the conventional methods, the author of this paper intended to suggest more improved analytical methods and derived the elements which might occur during analysis or required improvements. The method suggested in this study is able to reduce the uncertainty and errors which may be existent in evaluating the {sup 3}H concentration of environmental sample s and thus will serve as the best solution in the technical and economic point of view. Liquid Scintillation Counter is the most widely used to analyze ultra-low level {sup 3}H by using CPM / DPM Counting Mode using external radiation source and Spectrum Plot Mode using internal radiation source. In CPM / DPM Counting Mode, multiple samples can be measured by single calibration despite its rather higher background whereas Spectrum Plot Mode requires more time and cost to analyze multiple samples despite its reliability to reduce the contribution of other radionuclides.

  12. Theoretical study of structure and stability of small gadolinium carboxylate complexes in liquid scintillator solvents.

    Science.gov (United States)

    Huang, Pin-Wen

    2014-09-01

    The structural properties of three small gadolinium carboxylate complexes in three liquid scintillator solvents (pseudocumene, linear alkylbenzene, and phenyl xylylethane) were theoretically investigated using density functional theory (B3LYP/LC-RECP) and polarizable continuum model (PCM). The average interaction energy between gadolinium atom and carboxylate ligand (E(int)) and the energy difference of the highest singly occupied molecular orbital and lowest unoccupied molecular orbital (Δ(SL)) were calculated to evaluate and compare the relative stability of these complexes in solvents. The calculation results show that the larger (with a longer alkyl chain) gadolinium carboxylate complex has greater stability than the smaller one, while these gadolinium carboxylates in linear alkylbenzene were found to have greater stability than those in the other two solvents.

  13. Laboratory measurement of radioactivity purification for 212Pb in liquid scintillator

    Science.gov (United States)

    Hu, Wei; Fang, Jian; Yu, Bo-Xiang; Zhang, Xuan; Zhou, Li; Cai, Xiao; Sun, Li-Jun; Liu, Wan-Jin; Wang, Lan; Lü, Jun-Guang

    2016-09-01

    Liquid scintillator (LS) has been widely used in past and running neutrino experiments, and is expected also to be used in future experiments. Requirements on LS radio-purity have become higher and higher. Water extraction is a powerful method to remove soluble radioactive nuclei, and a mini-extraction station has been constructed. To evaluate the extraction efficiency and optimize the operation parameters, a setup to load radioactivity to LS and a laboratory scale setup to measure radioactivity using the 212Bi-212Po-208Pb cascade decay have been developed. Experience from this laboratory study will be useful for the design of large scale water extraction plants and the optimization of working conditions in the future. Supported by The Strategic Priority Research Program of the Chinese Academy of Sciences (XDA10010500), Natural Science Foundation of China (11390384)

  14. Characterization of liquid scintillation detector (BC-501A) and digital pulse shape discrimination (DPSD) system

    Energy Technology Data Exchange (ETDEWEB)

    Lombigit, L., E-mail: lojius@nm.gov.my; Yussup, N., E-mail: nolida@nm.gov.my; Ibrahim, Maslina Mohd; Rahman, Nur Aira Abd; Rawi, M. Z. M. [Instrumentation Group, Malaysian Nuclear Agency, Bangi, 43000 Kajang, Selangor (Malaysia)

    2015-04-29

    A digital n/γ pulse shape discrimination (PSD) system is currently under development at Instrumentation and Automation Centre, Malaysian Nuclear Agency. This system aims at simultaneous detection of fast neutron and gamma ray in mixed radiations environment. This work reports the system characterization performed on the liquid scintillation detector (BC-501A) and digital pulse shape discrimination (DPSD) system. The characterization involves measurement of electron light output from the BC-501A detector and energy channels calibration of the pulse height spectra acquired with DPSD system using set of photon reference sources. The main goal of this experiment is to calibrate the ADC channel of our DPSD system, characterized the BC-501 detector and find the position of Compton edge which later could be used as threshold for the n/γ PSD experiment. The detector resolution however is worse as compared to other published data but it is expected as our detector has a smaller active volume.

  15. Measurement of the neutron spectrum of a Pu-C source with a liquid scintillator

    Institute of Scientific and Technical Information of China (English)

    WANG Song-Lin; HUANG Han-Xiong; RUAN Xi-Chao; LI Xia; BAO Jie; NIE Yang-So; ZHONG Qi-Ping; ZHOU Zu-Ying; KONG Xiang-Zhong

    2009-01-01

    The neutron response function for a BC501A liquid scintillator (LS) has been measured using a series of monoenergetic neutrons produced by the p-T reaction. The proton energies were chosen such as to produce neutrons in the energy range of 1 to 20 MeV. The principles of the technique of unfolding a neutron energy spectrum by using the measured neutron response function and the measured Pulse Height (PH) spectrum is briefly described. The PH spectrum of neutrons from the Pu-C source, which will be used for the calibration of the reactor antineutrino detectors for the Daya Bay neutrino experiment, was measured and analyzed to get the neutron energy spectrum. Simultaneously the neutron energy spectrum of an Am-Be source was measured and compared with other measurements as a check of the result for the Pu-C source. Finally, an error analysis and a discussion of the results are given.

  16. Attenuation length measurements of liquid scintillator with LabVIEW and reliability evaluation of the device

    CERN Document Server

    Gao, L; Ding, YY; Zhou, L; Wen, LJ; Xie, YG; Wang, ZG; Cai, X; Sun, XL; Fang, J; Xue, Z; Zhang, AW; LÜ, QW; Sun, LJ; Ge, YS; Liu, YB; Niu, SL; Hu, T; Cao, J; LÜ, JG

    2013-01-01

    The attenuation length measuring device was constructed by using oscilloscope and LabVIEW for signal acquisition and processing. The performance of the device has been tested with a variety of ways, the test results show that the set-up has a good stability and high precision (sigma/mean reached 0.4 percent). Besides, the accuracy of the measurement system will decrease by about 17 percent if a filter is used. The attenuation length of gadolinium-loaded liquid scintillator (Gd-LS) was measured as 15.10 plus or minus 0.35 m where Gd-LS was heavily used in Daya Bay Neutrino Experiment. In addition, one method based on the Beer-Lambert law was proposed to investigate the reliability of the measurement device, the R-square reached 0.9995. Moreover, three purification methods for Linear Alkyl Benzene (LAB) production were compared in the experiment.

  17. Calibration of a liquid scintillation counter to assess tritium levels in various samples

    CERN Document Server

    Al-Haddad, M N; Abu-Jarad, F A

    1999-01-01

    An LKB-Wallac 1217 Liquid Scintillation Counter (LSC) was calibrated with a newly adopted cocktail. The LSC was then used to measure tritium levels in various samples to assess the compliance of tritium levels with the recommended international levels. The counter was calibrated to measure both biological and operational samples for personnel and for an accelerator facility at KFUPM. The biological samples include the bioassay (urine), saliva, and nasal tests. The operational samples of the light ion linear accelerator include target cooling water, organic oil, fomblin oil, and smear samples. Sets of standards, which simulate various samples, were fabricated using traceable certified tritium standards. The efficiency of the counter was obtained for each sample. The typical range of the efficiencies varied from 33% for smear samples down to 1.5% for organic oil samples. A quenching curve for each sample is presented. The minimum detectable activity for each sample was established. Typical tritium levels in bio...

  18. High Resolution Tracking Devices Based on Capillaries Filled with Liquid Scintillator

    CERN Multimedia

    Bonekamper, D; Vassiltchenko, V; Wolff, T

    2002-01-01

    %RD46 %title\\\\ \\\\The aim of the project is to develop high resolution tracking devices based on thin glass capillary arrays filled with liquid scintillator. This technique provides high hit densities and a position resolution better than 20 $\\mu$m. Further, their radiation hardness makes them superior to other types of tracking devices with comparable performance. Therefore, the technique is attractive for inner tracking in collider experiments, microvertex devices, or active targets for short-lived particle detection. High integration levels in the read-out based on the use of multi-pixel photon detectors and the possibility of optical multiplexing allow to reduce considerably the number of output channels, and, thus, the cost for the detector.\\\\ \\\\New optoelectronic devices have been developed and tested: the megapixel Electron Bombarded CCD (EBCCD), a high resolution image-detector having an outstanding capability of single photo-electron detection; the Vacuum Image Pipeline (VIP), a high-speed gateable pi...

  19. Development and Characterization of 6Li-doped Liquid Scintillator Detectors for PROSPECT

    Science.gov (United States)

    Gaison, Jeremy; Prospect Collaboration

    2016-09-01

    PROSPECT, the Precision Reactor Oscillation and Spectrum experiment, is a phased reactor antineutrino experiment designed to search for eV-scale sterile neutrinos via short-baseline neutrino oscillations and to make a precision measurement of the 235U reactor antineutrino spectrum. A multi-ton, optically segmented detector will be deployed at Oak Ridge National Laboratory's (ORNL) High Flux Isotope Reactor (HFIR) to measure the reactor spectrum at baselines ranging from 7-12m. A two-segment detector prototype with 50 liters of active liquid scintillator target has been built to verify the detector design and to benchmark its performance. In this presentation, we will summarize the performance of this detector prototype and describe the optical and energy calibration of the segmented PROSPECT detectors.

  20. ecCNO solar neutrinos: A challenge for gigantic ultra-pure liquid scintillator detectors

    Directory of Open Access Journals (Sweden)

    F.L. Villante

    2015-03-01

    Full Text Available Neutrinos produced in the Sun by electron capture reactions on 13N, 15O and 17F, to which we refer as ecCNO neutrinos, are not usually considered in solar neutrino analysis since the expected fluxes are extremely low. The experimental determination of this sub-dominant component of the solar neutrino flux is very difficult but could be rewarding since it provides a determination of the metallic content of the solar core and, moreover, probes the solar neutrino survival probability in the transition region at Eν∼2.5 MeV. In this Letter, we suggest that this difficult measure could be at reach for future gigantic ultra-pure liquid scintillator detectors, such as LENA.

  1. Evaluation of the ionization quenching correction for several liquid scintillators; Evaluacion de la extincion por ionizacion para diversos liquidos centelleadores

    Energy Technology Data Exchange (ETDEWEB)

    Los Arcos, J. M.; Borras, C.

    1990-07-01

    The most appropriate computational model for the ionization quenching function Q(E) is analyzed for electrons in liquid scintillators. A numerical evaluation of Q(E) from 0.1 keV to 3 MeV which the kB parameter varying between 0.005 and 0.010 cm/MeV is presented for seven scintillators; Toluene, Toluene-Alcohol, PCS, Toluene-CCl4, INSTAGEL, Dioxane-Naphtalene and HISAFE II. The numerical result are summarized as tables of Ieast squares fitting coefficient which make easy the computation of Q(E). (Author)

  2. Development of a new neutron monitor using a boron-loaded organic liquid scintillation detector

    CERN Document Server

    Rasolonjatovo, A H D; Kim, E; Nakamura, T; Nunomiya, T; Endo, A; Yamaguchi, Y; Yoshizawa, M

    2002-01-01

    A new type of neutron dose monitor was developed by using a 12.7 cm diameterx12.7 cm long boron-loaded organic liquid scintillation detector BC523A. This detector aims to have a response in the wide energy range of thermal energy to 100 MeV by using the H and C reactions to the fast neutrons of organic liquid and the sup 1 sup 0 B(n, alpha) reaction to thermalized neutrons in the liquid. The response functions of this detector were determined by the Monte Carlo simulation in the energy region from thermal energy to 100 MeV. Using these response functions, the spectrum-weighted dose function, G-function, to get the neutron dose from the light output spectrum of the detector was also determined by the unfolding technique. The calculated G-function was applied to determine the neutron dose in real neutron fields having energies ranging from thermal energy to several tens of MeV, where the light output spectra were measured with the BC523A detector. The thus-obtained ambient doses and effective doses show rather ...

  3. Development of a new neutron monitor using a boron-loaded organic liquid scintillation detector

    Energy Technology Data Exchange (ETDEWEB)

    Rasolonjatovo, A.H.D.; Shiomi, T.; Kim, E.; Nakamura, T. E-mail: nakamura@cyric.tohoku.ac.jp; Nunomiya, T.; Endo, A.; Yamaguchi, Y.; Yoshizawa, M

    2002-10-21

    A new type of neutron dose monitor was developed by using a 12.7 cm diameterx12.7 cm long boron-loaded organic liquid scintillation detector BC523A. This detector aims to have a response in the wide energy range of thermal energy to 100 MeV by using the H and C reactions to the fast neutrons of organic liquid and the {sup 10}B(n, {alpha}) reaction to thermalized neutrons in the liquid. The response functions of this detector were determined by the Monte Carlo simulation in the energy region from thermal energy to 100 MeV. Using these response functions, the spectrum-weighted dose function, G-function, to get the neutron dose from the light output spectrum of the detector was also determined by the unfolding technique. The calculated G-function was applied to determine the neutron dose in real neutron fields having energies ranging from thermal energy to several tens of MeV, where the light output spectra were measured with the BC523A detector. The thus-obtained ambient doses and effective doses show rather good agreement with the fluence-to-dose conversion factor given by ICRP 74. This detector will be useful as a wide-energy range neutron monitor.

  4. COCO, a Compton coincidence experiment to study liquid scintillator response in the 1-20 keV energy range

    Energy Technology Data Exchange (ETDEWEB)

    Peron, M.N. (Laboratoire Primaire des Rayonnements Ionisants, CEA/DAMRI, CE Saclay, BP 52, 91193 Gif-sur-Yvette Cedex (France)); Cassette, P. (Laboratoire Primaire des Rayonnements Ionisants, CEA/DAMRI, CE Saclay, BP 52, 91193 Gif-sur-Yvette Cedex (France))

    1994-12-30

    The use of Liquid Scintillation Counting (LSC) as a fundamental radionuclide standardisation method requires a correct description of the physical phenomena occurring during the LSC process. In that framework, a special point of interest is the description of the liquid scintillator response, especially for low-energy electrons, in a region where this response is known to be non-linear. As there is no simple way to produce monoenergetic electrons in the liquid scintillator, we have simulated these electrons using a Compton interaction coincidence method. Due to the energy conservation law, the selection of the energy of the scattered Compton X-ray photon is equivalent to the selection of the energy of a monoenergetic electron. This paper describes the experimental system and the methods used to analyse the experimental results in order to deduce the statistical distribution of the photons emitted by the scintillator. The effects of some artefacts are discussed, including the accidental coincidences and the influence of cascade Compton interactions. ((orig.))

  5. Patient-specific quality assurance for spot scanning proton beams using a large-volume liquid scintillator detector

    Science.gov (United States)

    Robertson, D.; Beddar, S.

    2017-05-01

    A large-volume liquid scintillator detector was used to measure individual energy layers from a clinical prostate treatment plan on a scanning proton beam system. Lateral and beam’s-eye view images of the dose distribution were acquired with two CCD cameras facing adjacent sides of a scintillator tank. The measured dose images were compared with calculated dose distributions from a validated Monte Carlo model. The measured and calculated dose distributions showed good agreement, with the exception of the Bragg peak region of the lateral view, which exhibited ionization quenching. The beam’s-eye and lateral views achieved gamma analysis passing rates of 99.7% and 92.5%, respectively, using gamma criteria of 3%, 3 mm. Large-volume scintillator detectors show promise for quick and accurate measurements of patient treatment fields for scanning proton beam systems.

  6. Optics study of liquid scintillation counting systems; Estudio de la Optica en sistemas de medida por centelle liquido

    Energy Technology Data Exchange (ETDEWEB)

    Duran Ramiro, M. T.; Garcia-Torano, E.

    2005-07-01

    Optics is a key issue in the development of any liquid scintillation counting (LSC) system. Light emission in the scintillating solution, transmission through the vial and reflector design are some aspects that need to be considered in detail. This paper describes measurements and calculations carried out to optimise these factors for the design of a new family of LSC counters. Measurements of the light distribution emitted by a scintillation vial were done by autoradiographs of cylindrical vials made of various materials and results were compared to those obtained by direct measurements of the light distribution made by scanning the vial with a photomultiplier tube. Calculations were also carried out to study the light transmission in the vial and the optimal design of the reflector for a system with one photomultiplier tube. (Author)

  7. Review of plastic and liquid scintillation dosimetry for photon, electron, and proton therapy

    Science.gov (United States)

    Beaulieu, Luc; Beddar, Sam

    2016-10-01

    While scintillation dosimetry has been around for decades, the need for a dosimeter tailored to the reality of modern radiation therapy—in particular a real-time, water-equivalent, energy-independent dosimeter with high spatial resolution—has generated renewed interest in scintillators over the last 10 years. With the advent of at least one commercial plastic scintillation dosimeter and the ever-growing scientific literature on this subject, this topical review is intended to provide the medical physics community with a wide overview of scintillation physics, related optical concepts, and applications of plastic scintillation dosimetry.

  8. Characterizing a fast-response, low-afterglow liquid scintillator for neutron time-of-flight diagnostics in fast ignition experiments

    Energy Technology Data Exchange (ETDEWEB)

    Abe, Y., E-mail: abe-y@ile.osaka-u.ac.jp; Hosoda, H.; Arikawa, Y.; Nagai, T.; Kojima, S.; Sakata, S.; Inoue, H.; Iwasa, Y.; Iwano, K.; Yamanoi, K.; Fujioka, S.; Nakai, M.; Sarukura, N.; Shiraga, H.; Norimatsu, T.; Azechi, H. [Institute of Laser Engineering, Osaka University, 2-6 Yamada-oka, Suita, Osaka 565-0871 (Japan)

    2014-11-15

    The characteristics of oxygen-enriched liquid scintillators with very low afterglow are investigated and optimized for application to a single-hit neutron spectrometer for fast ignition experiments. It is found that 1,2,4-trimethylbenzene has better characteristics as a liquid scintillator solvent than the conventional solvent, p-xylene. In addition, a benzophenon-doped BBQ liquid scintillator is shown to demonstrate very rapid time response, and therefore has potential for further use in neutron diagnostics with fast time resolution.

  9. Landau Energy Loss in Liquid Scintillator and the Search for Wifs with the LVD Experiment.

    Science.gov (United States)

    Tang, Jie

    The LVD experiment at Gran Sasso, Italy, is described, and data since the completion of the first tower (one fifth of the whole LVD) are analyzed. The dE/dx distribution of reconstructed high-energy muons in the scintillator counters is obtained. This distribution is compared with predictions by a GEANT3 Monte Carlo simulation of cosmic muons going through the LVD detector. Its shape is similar to the Landau approximation. In the data from a total running time of 245 days, 159286 clearly separable charged tracks going through the detector were reconstructed. No WIF (Weakly-Interacting Fractionally-charged particle) is observed. Since the early 1930's to the 1980's, theories on the dE/dx distribution of charged particles in matter have evolved from the fundamental work done by Bethe, Bloch, Landau, Symon, Vavilov and others with the inclusion of more precise corrections of the density effect and the shell effect. At the LVD experiment, through a procedure of gain-factor calibration at every period of 20 days, to compensate for instability and nonuniformity of the scintillator counters and their readout, the muon dE/dx distribution is measured; it conforms to the Landau approximation. The precision of the dE/dx measurement is 7.6% (one sigma).. WIF particles are speculated by modern theories. Because dE/dx is proportional to the square of the charge carried by the incident particle, any WIF going through the LVD liquid scintillator will reveal itself by its dE/dx being on the low side of the carefully calibrated muon dE/dx distribution. Calculation has shown that when the charge of a WIF is as low as {2over 3} e, it still generates enough ionization in the LVD limited streamer tubes and thus its track is as visible as a muon track in the detector. Such events are not found. Assuming a uniform flux distribution of WIF particles coming from the atmosphere, the upper limit of their flux at the LVD site is 4.4 times rm 10^{-14} cm^{-2}sterad ^{-1}sec^{-1}. (Copies

  10. Liquid scintillation counting methodology for 99Tc analysis. A remedy for radiopharmaceutical waste

    Energy Technology Data Exchange (ETDEWEB)

    Khan, Mumtaz [Univ. of Science and Technology, Gyeongbuk (Korea); Um, Wooyong [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-08-13

    This paper presents a new approach for liquid scintillation counting (LSC) analysis of single-radionuclide samples containing appreciable organic or inorganic quench. This work offers better analytical results than existing LSC methods for technetium-99 (99gTc) analysis with significant savings in analysis cost and time. The method was developed to quantify 99gTc in environmental liquid and urine samples using LSC. Method efficiency was measured in the presence of 1.9 to 11,900 ppm total dissolved solids. The quench curve was proved to be effective in the case of spiked 99gTc activity calculation for deionized water, tap water, groundwater, seawater, and urine samples. Counting efficiency was found to be 91.66% for Ultima Gold LLT (ULG-LLT) and Ultima Gold (ULG). Relative error in spiked 99gTc samples was ±3.98% in ULG and ULG-LLT cocktails. Minimum detectable activity was determined to be 25.3 mBq and 22.7 mBq for ULG-LLT and ULG cocktails, respectively. A pre-concentration factor of 1000 was achieved at 100°C for 100% chemical recovery.

  11. Comparison of the efficacy of biodegradable and non-biodegradable scintillation liquids on the counting of tritium- and [14C]-labeled compounds

    Directory of Open Access Journals (Sweden)

    Medeiros R.B.

    2003-01-01

    Full Text Available The widespread use of ³H and 14C in research has generated a large volume of waste mixed with scintillation liquid, requiring an effective control and appropriate storage of liquid radioactive waste. In the present study, we compared the efficacy of three commercially available scintillation liquids, Optiphase HiSafe 3, Ultima-Gold(TM AB (biodegradable and Insta-Gel-XF (non-biodegradable, in terms of [14C]-glucose and [³H]-thymidine counting efficiency. We also analyzed the effect of the relative amount of water (1.6 to 50%, radioisotope concentration (0.1 to 100 nCi/ml, pH (2 to 10 and color of the solutions (samples containing 0.1 to 1.0 mg/ml of Trypan blue on the counting efficiency in the presence of these scintillation liquids. There were few significant differences in the efficiency of 14C and ³H counting obtained with biodegradable or non-biodegradable scintillation liquids. However, there was an 83 and 94% reduction in the efficiency of 14C and ³H counting, respectively, in samples colored with 1 mg/ml Trypan blue, but not with 0.1 mg/ml, independent of the scintillation liquid used. Considering the low cost of biodegradable scintillation cocktails and their efficacy, these results show that traditional hazardous scintillation fluids may be replaced with the new safe biodegradable fluids without impairment of ³H and 14C counting efficiency. The use of biodegradable scintillation cocktails minimizes both human and environmental exposure to hazardous solvents. In addition, some biodegradable scintillation liquids can be 40% less expensive than the traditional hazardous cocktails.

  12. Digital liquid-scintillation counting and effective pulse-shape discrimination with artificial neural networks

    Energy Technology Data Exchange (ETDEWEB)

    Langrock, Gert; Wiehl, Norbert; Kling, Hans-Otto; Mendel, Matthias; Naehler, Andrea; Tharun, Udo; Eberhardt, Klaus; Trautmann, Norbert; Kratz, Jens Volker [Mainz Univ. (Germany). Inst. fuer Kernchemie; Omtvedt, Jon-Petter [Oslo Univ. (Norway). Dept. of Chemistry; Skarnemark, Gunnar [Chalmers Univ. of Technology, Goeteborg (Sweden)

    2015-05-01

    A typical problem in low-level liquid scintillation (LS) counting is the identification of α particles in the presence of a high background of β and γ particles. Especially the occurrence of β-β and β-γ pile-ups may prevent the unambiguous identification of an α signal by commonly used analog electronics. In this case, pulse-shape discrimination (PSD) and pile-up rejection (PUR) units show an insufficient performance. This problem was also observed in own earlier experiments on the chemical behaviour of transactinide elements using the liquid-liquid extraction system SISAK in combination with LS counting. α-particle signals from the decay of the transactinides could not be unambiguously assigned. However, the availability of instruments for the digital recording of LS pulses changes the situation and provides possibilities for new approaches in the treatment of LS pulse shapes. In a SISAK experiment performed at PSI, Villigen, a fast transient recorder, a PC card with oscilloscope characteristics and a sampling rate of 1 giga samples s{sup -1} (1 ns per point), was used for the first time to record LS signals. It turned out, that the recorded signals were predominantly α β-β and β-γ pile up, and fission events. This paper describes the subsequent development and use of artificial neural networks (ANN) based on the method of 'back-propagation of errors' to automatically distinguish between different pulse shapes. Such networks can 'learn' pulse shapes and classify hitherto unknown pulses correctly after a learning period. The results show that ANN in combination with fast digital recording of pulse shapes can be a powerful tool in LS spectrometry even at high background count rates.

  13. Measurement of Trace $^{129}I$ Concentrations in CsI Powder and Organic Liquid Scintillator with Accelerator Mass Spectrometry

    CERN Document Server

    Dong, K J

    2007-01-01

    Levels of trace radiopurity in active detector materials is a subject of major concern in low-background experiments. Procedures were devised to measure trace concentrations of I-129 in the inorganic salt CsI as well as in organic liquid scintillator with Accelerator Mass Spectrometry (AMS) which leads to improvement in sensitivities by several orders of magnitude over other methods. No evidence of their existence in these materials were observed. Limits of < 6 X 10^{-13} g/g and < 2.6 X 10^{-17} g/g on the contaminations of I-129 in CsI and liquid scintillator, respectively, were derived.These are the first results in a research program whose goals are to develop techniques to measure trace radioactivity in detector materials by AMS.

  14. Liquid Scintillation Counting of Environmental Radioisotopes: A Review of the Impact of Background Reduction

    Energy Technology Data Exchange (ETDEWEB)

    Douglas, Matthew; Bernacki, Bruce E.; Erchinger, Jennifer L.; Finn, Erin C.; Fuller, Erin S.; Hoppe, Eric W.; Keillor, Martin E.; Morley, Shannon M.; Mullen, Crystal A.; Orrell, John L.; Panisko, Mark E.; Warren, Glen A.; Wright, Michael E.

    2016-03-09

    Liquid scintillation counting (LSC) is a versatile and commonplace method for radiometric measurement of charged particle emitting radionuclides. The LSC method provides utility in a range of environmental science applications including hydrological studies of water transport, anthropogenic releases of radionuclides into the environment, and vertical mixing rates within oceans. Instrumental measurement background is one limiting factor of radiometric measurement sensitivity. As part of the development of a custom low background LSC system located in a shallow underground laboratory at Pacific Northwest National Laboratory, a number of measurement applications of LSC have been considered and are summarized here. The focus is on determining which aspects of such measurements would gain the greatest benefit from the reduction of LSC backgrounds by a factor of 10-100 relative to values reported in the literature. Examples of benefits include lowering the minimum detectable activity, reducing the sample size required, and shortening the elapsed timeline of the processing and analysis sequence. In particular tritium, strontium, and actinium isotopes are examined as these isotopes cover a range of requirements related to the LSC measurement method (e.g., 3H: low energy; Sr: spectral deconvolution; Ac: alpha/beta discrimination).

  15. Spectrum library concept and pulse shape analysis in liquid scintillation counting

    Energy Technology Data Exchange (ETDEWEB)

    Kaihola, L. [Wallac Oy, Turku (Finland)

    1997-03-01

    Wallac introduced in 1990 a new absolute liquid scintillation counting (LSC) method, Digital Overlay Technique (DOT) to correct for quench. This method allows quantization of multilabel samples by referring to library spectra which are generated against chemical and color quench indices at the factory. The libraries can further be expanded to any beta emitter by user with a method called fine tuning, which can be carried out even with a single sample. Spectrum libraries are created over the whole spectrum range of the radionuclide and allow automatic identification of a single label beta emitting radionuclide, called Easy Count method. Another improvement in LSC is commercial introduction of Pulse Shape Analysis (PSA) in 1986 by Wallac. This method recognizes alpha particle decay by pulse shape and leads to excellent sensitivity in alpha counting because most of the background signal in LSC comprises of short or beta like pulses. PSA detects alpha events in the presence of high excess of beta activity over alphas, up to a ratio 100000 to 1. (orig.)

  16. Neutron and photon spectrometry with liquid scintillation detectors in mixed fields

    CERN Document Server

    Klein, H

    2002-01-01

    Liquid scintillation detectors of type NE213 or BC501A are well suited and routinely used for spectrometry in mixed n-gamma-fields. Neutron- and photon-induced pulse height spectra may be simultaneously recorded making use of the n/gamma-discrimination capability based on pulse shape analysis. The light output functions for the detected secondary charged particles, i.e. electrons, positrons, protons and other charged reaction products, and the pulse height resolution function must carefully be determined. This can be done experimentally, in part via an iterative procedure by comparison with calculations. The response functions can then be reliably calculated by Monte Carlo simulations. Photon response functions calculated with the PHRESP code, which was developed on the basis of the EGS4+PRESTA program package, are in very good agreement with calibrations up to 17 MeV, both in shape and absolute scale. Similarly, neutron response functions calculated with the NRESP7 code well describe the pulse height spectra...

  17. Characterization of CaWO{sub 4} scintillator at room and liquid nitrogen temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Moszynski, M. [Soltan Institute for Nuclear Studies, PL 05-400 Otwock-Swierk (Poland)]. E-mail: marek@ipj.gov.pl; Balcerzyk, M. [Soltan Institute for Nuclear Studies, PL 05-400 Otwock-Swierk (Poland); Czarnacki, W. [Soltan Institute for Nuclear Studies, PL 05-400 Otwock-Swierk (Poland); Nassalski, A. [Soltan Institute for Nuclear Studies, PL 05-400 Otwock-Swierk (Poland); Szczesniak, T. [Soltan Institute for Nuclear Studies, PL 05-400 Otwock-Swierk (Poland); Kraus, H. [Department of Physics, University of Oxford, Keble Road, Oxford OX1 3RH (United Kingdom); Mikhailik, V.B. [Department of Physics, University of Oxford, Keble Road, Oxford OX1 3RH (United Kingdom); Solskii, I.M. [Institute of Materials SRC ' Carat' , Lviv 790031 (Ukraine)

    2005-11-21

    The properties of CaWO{sub 4} (CaWO) crystals in {gamma}-spectrometry were studied at room and liquid nitrogen(LN{sub 2}) temperatures. Two small samples of 10x10x4 mm{sup 3} and 10x10x8 mm{sup 3} size were tested, coupled to a Photonis XP3212 photomultiplier at room temperature and a large area avalanche photodiode at LN{sub 2} temperature. Light pulse shape and light output at room and LN{sub 2} temperatures were measured. Energy resolution and non-proportionality of the CaWO response versus {gamma}-ray energy were studied and compared with those of small BGO and CdWO{sub 4} crystals to discuss further the origin of the intrinsic resolution of undoped scintillating crystals. A high light output of 4800{+-}200 phe/MeV and a good energy resolution of 6.6{+-}0.2% for 662 keV {gamma}-rays from a {sup 137}Cs source were measured for the small samples coupled to the XP3212 photomultiplier.

  18. ACID EVAPORATION OF ULTIMA GOLD TM AB LIQUID SCINTILLATION COCKTAIL RESIDUE

    Energy Technology Data Exchange (ETDEWEB)

    Kyser, E.; Fondeur, F.; Crump, S.

    2011-12-21

    Prior analyses of samples from the F/H Lab solutions showed the presence of diisopropylnapthalene (DIN), a major component of Ultima Gold{trademark} AB liquid scintillation cocktail (LSC). These solutions are processed through H-Canyon Tank 10.5 and ultimately through the 17.8E evaporator. Similar solutions originated in SRNL streams sent to the same H Canyon tanks. This study examined whether the presence of these organics poses a process-significant hazard for the evaporator. Evaporation and calorimetry testing of surrogate samples containing 2000 ppm of Ultima Gold{trademark} AB LSC in 8 M nitric acid have been completed. These experiments showed that although reactions between nitric acid and the organic components do occur, they do not appear to pose a significant hazard for runaway reactions or generation of energetic compounds in canyon evaporators. The amount of off-gas generated was relatively modest and appeared to be well within the venting capacity of the H-Canyon evaporators. A significant fraction of the organic components likely survives the evaporation process primarily as non-volatile components that are not expected to represent any new process concerns during downstream operations such as neutralization. Laboratory Waste solutions containing minor amounts of DIN can be safely received, stored, transferred, and processed through the canyon waste evaporator.

  19. A high-resolution tracking hodoscope based on capillary layers filled with liquid scintillator

    CERN Document Server

    Bay, A; Bruski, N; Buontempo, S; Currat, C; D'Ambrosio, N; Ekimov, A V; Ereditato, A; Fabre, Jean-Paul; Fanti, V; Frekers, D; Frenkel, A; Golovkin, S V; Govorun, V N; Harrison, K; Koppenburg, P; Kozarenko, E N; Kreslo, I E; Liberti, B; Martellotti, G; Medvedkov, A M; Mondardini, M R; Penso, G; Siegmund, W P; Vasilchenko, V G; Vilain, P; Wilquet, G; Winter, Klaus; Wörtche, H J

    2001-01-01

    Results are given on tests of a high-resolution tracking hodoscope based on layers of \\hbox{26-$\\mu$m-bore} glass capillaries filled with organic liquid scintillator (1-methylnaphthalene doped with R39). The detector prototype consisted of three 2-mm-thick parallel layers, with surface areas of $2.1 \\times 21$~cm$^2$. The layers had a centre-to-centre spacing of 6~mm, and were read by an optoelectronic chain comprising two electrostatically focused image intensifiers and an Electron-Bombarded Charge-Coupled Device (EBCCD). Tracks of cosmic-ray particles were recorded and analysed. The observed hit density was 6.6~hits/mm for particles crossing the layers perpendicularly, at a distance of 1~cm from the capillaries' readout end, and 4.2~hits/mm for particles at a distance of 20~cm. A track segment reconstructed in a single layer had an rms residual of $\\sim$~20~$\\mu$m, and allowed determination of the track position in a neighbouring layer with a precision of $\\sim$~170~$\\mu$m. This latter value corresponded to...

  20. Discrimination of neutrons and γ-rays in liquid scintillator based on Elman neural network

    Science.gov (United States)

    Zhang, Cai-Xun; Lin, Shin-Ted; Zhao, Jian-Ling; Yu, Xun-Zhen; Wang, Li; Zhu, Jing-Jun; Xing, Hao-Yang

    2016-08-01

    In this work, a new neutron and γ (n/γ) discrimination method based on an Elman Neural Network (ENN) is proposed to improve the discrimination performance of liquid scintillator (LS) detectors. Neutron and γ data were acquired from an EJ-335 LS detector, which was exposed in a 241Am-9Be radiation field. Neutron and γ events were discriminated using two methods of artificial neural network including the ENN and a typical Back Propagation Neural Network (BPNN) as a control. The results show that the two methods have different n/γ discrimination performances. Compared to the BPNN, the ENN provides an improved of Figure of Merit (FOM) in n/γ discrimination. The FOM increases from 0.907 ± 0.034 to 0.953 ± 0.037 by using the new method of the ENN. The proposed n/γ discrimination method based on ENN provides a new choice of pulse shape discrimination in neutron detection. Supported by National Natural Science Foundation of China (11275134,11475117)

  1. 210Pb and 210Po determination in environmental samples using liquid scintillation counting and alpha spectrometry

    Science.gov (United States)

    Pérez Sánchez, D.; Martin Sánchez, A.; Jurado Vargas, M.

    2003-01-01

    A simple radiochemical procedure has been developed to determine 210Pb and 210Po in environmental samples from the same matrix. Sediment samples are decomposed by leaching with mineral acids or by microwave digestion, while water samples are pre-concentrated. One part of the resulting solution, spiked with 209Po, is used for 210Po determination by spontaneous deposition onto nickel disks (α-spectrometry). The other part is assayed for 210Pb, separating the Pb either by anion-exchange (sediment samples), or by solvent extraction (water samples). The 210Pb source is finally prepared by precipitation as oxalate and the chemical recovery determined by gravimetry. The 210Pb activity concentration is determined by liquid scintillation. A standard sediment sample supplied by IAEA and spiked water samples were analysed to check the procedure. The 210Pb and 210Po measurements agreed well with the certifications, deviations being less than 10%. The mean recoveries for Pb and Po were (70±12)% and (77±8%) for sediments, and (70±10)% and (81±7)% for waters, respectively.

  2. Pulse-shape discrimination and energy resolution of a liquid-argon scintillator with xenon doping

    CERN Document Server

    Wahl, Christopher G; Lippincott, W Hugh; Nikkel, James A; Shin, Yunchang; McKinsey, Daniel N

    2014-01-01

    Liquid-argon scintillation detectors are used in fundamental physics experiments and are being considered for security applications. Previous studies have suggested that the addition of small amounts of xenon dopant improves performance in light or signal yield, energy resolution, and particle discrimination. In this study, we investigate the detector response for xenon dopant concentrations from 9 +/- 5 ppm to 1100 +/- 500 ppm xenon (by weight) in 6 steps. The 3.14-liter detector uses tetraphenyl butadiene (TPB) wavelength shifter with dual photomultiplier tubes and is operated in single-phase mode. Gamma-ray-interaction signal yield of 4.0 +/- 0.1 photoelectrons/keV improved to 5.0 +/- 0.1 photoelectrons/keV with dopant. Energy resolution at 662 keV improved from (4.4 +/- 0.2)% ({\\sigma}) to (3.5 +/- 0.2)% ({\\sigma}) with dopant. Pulse-shape discrimination performance degraded greatly at the first addition of dopant, slightly improved with additional additions, then rapidly improved near the end of our dopa...

  3. Using the transportable, computer-operated, liquid-scintillator fast-neutron spectrometer system

    Energy Technology Data Exchange (ETDEWEB)

    Thorngate, J.H.

    1988-11-01

    When a detailed energy spectrum is needed for radiation-protection measurements from approximately 1 MeV up to several tens of MeV, organic-liquid scintillators make good neutron spectrometers. However, such a spectrometer requires a sophisticated electronics system and a computer to reduce the spectrum from the recorded data. Recently, we added a Nuclear Instrument Module (NIM) multichannel analyzer and a lap-top computer to the NIM electronics we have used for several years. The result is a transportable fast-neutron spectrometer system. The computer was programmed to guide the user through setting up the system, calibrating the spectrometer, measuring the spectrum, and reducing the data. Measurements can be made over three energy ranges, 0.6--2 MeV, 1.1--8 MeV, or 1.6--16 MeV, with the spectrum presented in 0.1-MeV increments. Results can be stored on a disk, presented in a table, and shown in graphical form. 5 refs., 51 figs.

  4. Development of a liquid scintillator-based 3D detector for range measurements of spot-scanned proton beams

    Science.gov (United States)

    Darne, C. D.; Robertson, D.; Beddar, S.

    2017-05-01

    The goal of the present study is to develop a liquid scintillator-based 3D detector and investigate its performance for beam range measurements in real time. The detector design consists of a tank filled with water-equivalent liquid scintillator that scintillates in response to incident proton beams. Three scientific complementary metal-oxide semiconductor (sCMOS) cameras collect the resulting optical signals. Preliminary measurements have shown that the optical detection system can record light distribution profiles anywhere inside the tank with an average spatial resolution of 0.23 mm. By employing multiple cameras the system is capable of capturing high resolution 2D depth and beams-eye profiles of the delivered beam and can consequently localize the position of beam anywhere inside the tank. It is also shown that it is capable of accurately measuring proton beam range with no more than 0.3 mm difference from the nominal range. The detector system thus demonstrates its ability to perform fast, high-resolution, and precise beam range measurements in 3D.

  5. The light-yield response of a NE-213 liquid-scintillator detector measured using 2 -- 6 MeV tagged neutrons

    CERN Document Server

    Scherzinger, J; Annand, J R M; Fissum, K G; Hall-Wilton, R; Kanaki, K; Lundin, M; Nilsson, B; Perrey, H; Rosborg, A; Svensson, H

    2016-01-01

    The response of a NE-213 liquid-scintillator detector has been measured using tagged neutrons from 2--6 MeV originating from an Am/Be neutron source. The neutron energies were determined using the time-of-flight technique. Pulse-shape discrimination was employed to discern between gamma-rays and neutrons. The behavior of both the fast (35 ns) and the combined fast and slow (475 ns) components of the neutron scintillation-light pulses were studied. Three different prescriptions were used to relate the neutron maximum energy-transfer edges to the corresponding recoil-proton scintillation-light yields, and the results were compared to simulations. Parametrizations which predict the fast or total light yield of the scintillation pulses were also tested. Our results agree with both existing data and existing parametrizations. We observe a clear sensitivity to the portion and length of the neutron scintillation-light pulse considered.

  6. Study of SiPM custom arrays for scintillation light detection in a Liquid Argon Time Projection Chamber

    Science.gov (United States)

    Cervi, T.; Babicz, M. E.; Bonesini, M.; Falcone, A.; Kose, U.; Nessi, M.; Menegolli, A.; Pietropaolo, F.; Raselli, G. L.; Rossella, M.; Torti, M.; Zani, A.

    2017-03-01

    Liquid Argon Time Projection Chamber (LAr-TPC) technique has been established as one of the most promising for the next generation of experiments dedicated to neutrino and rare-event physics. LAr-TPCs have the fundamental feature to be able to both collect the charge and the scintillation light produced after the passage of a ionizing particle inside the Argon volume. Scintillation light is traditionally detected by large surface Photo-Multiplier Tubes (PMTs) working at cryogenic temperature. Silicon Photo-Multipliers (SiPMs) are semiconductor-based devices with performances comparable to the PMT ones, but with very small active areas. For this reason we built a prototype array composed by SiPMs connected in different electrical configurations. We present results on preliminary tests made with four SiPMs, connected both in parallel and in series configurations, deployed into a 50 liters LAr-TPC exposed to cosmic rays at CERN.

  7. Counting efficiencies by liquid scintillation counting. Single isomeric transitions; Eficiencia de recuento por centelleo liquido. Transiciones isomericas simples

    Energy Technology Data Exchange (ETDEWEB)

    Grau Carles, A.; Grau Malonda, A.

    1995-07-01

    In this work we present liquid scintillation counting efficiency tables for several radionuclides with single isomeric transitions, in which electron conversion and gamma emission processes are competitive. We study the radionuclides: 58mCo, 77mSe, 79mBr, 87mSr, S9mY, 93mNb, 103mRh, 107mAg, 109mAg, 113mIn, 131mXe, I33mXe, 135raBa, 137mBa, 167raEr, for two different scintillators, Ultima-Gold and Insta-Gel. We consider volumes of 10 and 15 mL for Ultima Gold, and 15 mL for Insta-Gel. (Author) 18 refs.

  8. Development of neutron-monitor detector using liquid organic scintillator coupled with 6Li + ZnS(Ag) Sheet.

    Science.gov (United States)

    Sato, Tatsuhiko; Endo, Akira; Yamaguchi, Yasuhiro; Takahashi, Fumiaki

    2004-01-01

    A phoswitch-type detector has been developed for monitoring neutron doses in high-energy accelerator facilities. The detector is composed of a liquid organic scintillator (BC501A) coupled with ZnS(Ag) sheets doped with 6Li. The dose from neutrons with energies above 1 MeV is evaluated from the light output spectrum of the BC501A by applying the G-function, which relates the spectrum to the neutron dose directly. The dose from lower energy neutrons, on the other hand, is estimated from the number of scintillations emitted from the ZnS(Ag) sheets. Characteristics of the phoswitch-type detector were studied experimentally in some neutron fields. It was found from the experiments that the detector has an excellent property of pulse-shape discrimination between the scintillations of BC501A and the ZnS(Ag) sheets. The experimental results also indicate that the detector is capable of reproducing doses from thermal neutrons as well as neutrons with energies from one to several tens of megaelectronvolts (MeV).

  9. A Measurement of the Absorption of Liquid Argon Scintillation Light by Dissolved Nitrogen at the Part-Per-Million Level

    CERN Document Server

    Jones, B J P; Conrad, J M; Ignarra, C M; Katori, T; Toups, M

    2013-01-01

    We report on a measurement of the absorption length of scintillation light in liquid argon due to dissolved nitrogen at the part-per-million (ppm) level. We inject controlled quantities of nitrogen into a high purity volume of liquid argon and monitor the light yield from an alpha source. The source is placed at different distances from a cryogenic photomultiplier tube assembly. By comparing the light yield from each position we extract the absorption cross section of nitrogen. We find that nitrogen absorbs argon scintillation light with strength of $\\left(1.51\\pm 0.15\\right)\\times10^{-4} \\;\\mathrm{cm^{-1} ppm^{-1}}$, corresponding to an absorption cross section of $\\left(4.99 \\pm 0.51 \\right)\\times10^{-21}\\;\\mathrm{cm^{2} molecule^{-1}}$. We obtain the relationship between absorption length and nitrogen concentration over the 0 to 50 ppm range and discuss the implications for the design and data analysis of future large liquid argon time projection chamber (LArTPC) detectors. Our results indicate that for a ...

  10. A Measurement of the Absorption of Liquid Argon Scintillation Light by Dissolved Nitrogen at the Part-Per-Million Level

    Energy Technology Data Exchange (ETDEWEB)

    Jones, B. J.P. [MIT, LNS; Chiu, C. S. [MIT, LNS; Conrad, J. M. [MIT, LNS; Ignarra, C. M. [MIT, LNS; Katori, T. [MIT, LNS; Toups, M. [MIT, LNS

    2013-07-24

    Here we report on a measurement of the absorption length of scintillation light in liquid argon due to dissolved nitrogen at the part-per-million (ppm)level. We inject controlled quantities of nitrogen into a high purity volume of liquid argon and monitor the light yield from an alpha source.The source is placed at different distances from a cryogenic photomultiplier tube assembly. By comparing the light yield from each position we extract the absorption cross section of nitrogen. We find that nitrogen absorbs argon scintillation light with strength of (1.51±0.15) × 10$-$4 cm$-$1ppm$-$1, correspondingto an absorption cross section of (4.99±0.51) × 10$-$21 cm2 molecule$-$1.We obtain the relationship between absorption length and nitrogenconcentration over the 0 to 50 ppm range and discuss the implicationsfor the design and data analysis of future large liquid argon time projection chamber (LArTPC)detectors. Our results indicate that for a current-generation LArTPC, wherea concentration of 2 parts per million of nitrogen is expected, the attenuationlength due to nitrogen will be 30±3 meters.

  11. The air luminescence count for the rapid determination of {sup 222}Rn in a liquid scintillation spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Morita-Murase, Yuko; Murakami, Isao; Homma, Yoshio [Laboratory for Radiopharmaceutical Chemistry, Kyoritsu College of Pharmacy, Tokyo (Japan)

    2001-03-01

    A liquid scintillation spectrometer has been applied to the determination of the counting efficiency for the air luminescence produced by standardized {sup 222}Rn and its daughters. Based on the counting efficiency, known amounts of {sup 222}Rn can be prepared in 3.5 h. Moreover, the {sup 226}Ra source from which {sup 222}Rn is collected does not necessary have to be a standard one. In contrast, the conventional method for preparing known amounts of {sup 222}Rn usually requires a long waiting period (ca. 15-30 days). (author)

  12. Chemical and colour quenching in liquid scintillation counting; Estudio de la extincion quimica y por color en centelleo liquido

    Energy Technology Data Exchange (ETDEWEB)

    Scott, P. E.; Grau, A.

    1987-07-01

    Chemical and colour quenching for H-3 and C-14 was studied. The method includes spectral analysis of colouring agents; methyl red, (4'-dimethylamine-azobenzene 2-carboxylic acid) dimethyl yellow (4'-dimethylamine-azobenzene) and malachite green (methane, bis .(4-dimethyl aminophenyl) - (phenyl)). External standard channels ratio was applied for the liquid scintillation counting of samples. The introduction of an isolated external standard seems to be a strong tool for the correction of chemical and colour quenching curves. (Author) 12 refs.

  13. Results of low energy background measurements with the Liquid Scintillation Detector (LSD) of the Mont Blanc Laboratory

    Science.gov (United States)

    Aglietta, M.; Badino, G.; Bologna, G. F.; Castagnoli, C.; Fulgione, W.; Galeotti, P.; Saavedra, O.; Trinchero, G. C.; Vernetto, S.; Dadykin, V. L.

    1985-01-01

    The 90 tons liquid scintillation detector (LSD) is fully running since October 1984, at a depth of 5,200 hg/sq cm of standard rock underground. The main goal is to search for neutrino bursts from collapsing stars. The experiment is very sensitive to detect low energy particles and has a very good signature to gamma-rays from (n,p) reaction which follows the upsilon e + p yields n + e sup + neutrino capture. The analysis of data is presented and the preliminary results on low energy measurements are discussed.

  14. Simultaneous reconstruction of scintillation light and ionization charge produced by 511 keV photons in liquid xenon: Potential application to PET

    Energy Technology Data Exchange (ETDEWEB)

    Amaudruz, P. [TRIUMF, 4004 Wesbrook Mall, Vancouver, BC, V6T 2A3 (Canada)], E-mail: amaudruz@triumf.ca; Bryman, D. [Department of Physics and Astronomy, University of British Columbia, 6224 Agricultural Road, Vancouver, BC, V6T 1Z1 (Canada)], E-mail: bryman@phas.ubc.ca; Kurchaninov, L. [TRIUMF, 4004 Wesbrook Mall, Vancouver, BC, V6T 2A3 (Canada)], E-mail: kurchan@triumf.ca; Lu, P. [Department of Physics and Astronomy, University of British Columbia, 6224 Agricultural Road, Vancouver, BC, V6T 1Z1 (Canada)], E-mail: philipfl@phas.ubc.ca; Marshall, C. [TRIUMF, 4004 Wesbrook Mall, Vancouver, BC, V6T 2A3 (Canada)], E-mail: cammarsh@triumf.ca; Martin, J.P. [University of Montreal, CP 6128 Succursale Centre-Ville, Montreal, Quebec, H3C 3J7 (Canada)], E-mail: jpmartin@lps.umontreal.ca; Muennich, A. [TRIUMF, 4004 Wesbrook Mall, Vancouver, BC, V6T 2A3 (Canada)], E-mail: muennich@triumf.ca; Retiere, F. [TRIUMF, 4004 Wesbrook Mall, Vancouver, BC, V6T 2A3 (Canada)], E-mail: fretiere@triumf.ca; Sher, A. [TRIUMF, 4004 Wesbrook Mall, Vancouver, BC, V6T 2A3 (Canada)], E-mail: sher@triumf.ca

    2009-08-21

    In order to assess the performance of liquid xenon detectors for use in positron emission tomography we studied the scintillation light and ionization charge produced by 511 keV photons in a small prototype detector. Scintillation light was detected with large area avalanche photodiodes while ionization electrons were collected on an anode instrumented with low noise electronics after drifting up to 3 cm. Operational conditions were studied as a function of the electric field. Energy resolutions of <10% (FWHM) were achieved by combining the scintillation light and ionization charge signals. The relationship between scintillation light and ionization signals was investigated. An analysis of the sources of fluctuations was performed in order to optimize future detector designs.

  15. Affect of Distinguishing of Neutron and Gamma for Liquid Scintillation Detector by Methods of Baseline Compensation

    Institute of Scientific and Technical Information of China (English)

    LI; Wei; LIU; Yi-na; LI; Chun-juan; WANG; Zhi-qiang; CHEN; Jun; LUO; Hai-long; ZHANG; Wei-hua; XU; Kun

    2015-01-01

    Most scintillation detectors are sensitive both for neutron and photon.Usually,there are photon in neutron fields which is coming from neutron source or reacting by neutron and materials around,so you must concern about the affect by photon which is below 10MeV.There will be a big effect for distinguishing

  16. Radiocarbon dating of archaeological samples (sambaqui) using CO(2) absorption and liquid scintillation spectrometry of low background radiation.

    Science.gov (United States)

    Mendonça, Maria Lúcia T G; Godoy, José M; da Cruz, Rosana P; Perez, Rhoneds A R

    2006-01-01

    Sambaqui means, in the Tupi language, a hill of shells. The sambaquis are archaeological sites with remains of pre-historical Brazilian occupation. Since the sambaqui sites in the Rio de Janeiro state region are older than 10,000 years, the applicability of CO(2) absorption on Carbo-sorb and (14)C determination by counting on a low background liquid scintillation counter was tested. In the present work, sambaqui shells were treated with H(3)PO(4) in a closed vessel in order to generate CO(2). The produced CO(2) was absorbed on Carbo-sorb. On saturation about 0.6g of carbon, as CO(2), was mixed with commercial liquid scintillation cocktail (Permafluor), and the (14)C activity determined by counting on a low background counter, Packard Tricarb 3170 TR/SL, for a period of 1000 mins to enable detection of a radiocarbon age of 22,400 BP. But only samples with ages up to 3500 BP were submitted to the method because the samples had been collected in the municipality of Guapimirim, in archaeological sambaqui-type sites belonging to this age range. The same samples were sent to the (14)C Laboratory of the Centro de Energia Nuclear na Agricultura (CENA/USP) where similar results were obtained.

  17. Study of digital pulse shape discrimination method for n-{\\gamma} separation of EJ-301 liquid scintillation detector

    CERN Document Server

    Wan, Bo; Chen, Liang; Ge, Honglin; Ma, Fei; Zhang, Hongbin; Ju, Yongqin; Zhang, Yanbin; Li, Yanyan; Xu, Xiaowei

    2015-01-01

    A digital pulse shape discrimination system based on a programmable module NI-5772 has been established and tested with EJ-301 liquid scintillation detector. The module was operated by means of running programs developed in LabVIEW with the sampling frequency up to 1.6GS/s. Standard gamma sources 22Na, 137Cs and 60Co were used to calibrate the EJ-301 liquid scintillation detector, and the gamma response function has been obtained. Digital algorithms for charge comparison method and zero-crossing method have been developed. The experimental results showed that both digital signal processing (DSP) algorithms could discriminate neutrons from gamma-rays. Moreover, the zero-crossing method shows better n-{\\gamma} discrimination at 80 keVee and lower, whereas the charge comparison method gives better results at higher thresholds. In addition, the figure-of-merit (FOM) of two different dimension detectors were extracted at 9 energy thresholds, and it was found that the smaller one presented a better n-{\\gamma} separ...

  18. Development of InP solid state detector and liquid scintillator containing metal complex for measurement of pp/7Be solar neutrinos and neutrinoless double beta decay

    Science.gov (United States)

    Fukuda, Yoshiyuki; Moriyama, Shigetaka

    2012-07-01

    A large volume solid state detector using a semi-insulating Indium Phosphide (InP) wafer have been developed for measurement of pp/7Be solar neutrinos. Basic performance such as the charge collection efficiency and the energy resolution were measured by 60% and 20%, respectively. In order to detect two gammas (115keV and 497keV) from neutrino capture, we have designed hybrid detector which consist InP detector and liquid xenon scintillator for IPNOS experiment. New InP detector with thin electrode (Cr 50Å- Au 50Å). For another possibility, an organic liquid scintillator containing indium complex and zirconium complex were studied for a measurement of low energy solar neutrinos and neutrinosless double beta decay, respectively. Benzonitrile was chosen as a solvent because of good solubility for the quinolinolato complexes (2 wt%) and of good light yield for the scintillation induced by gamma-ray irradiation. The photo-luminescence emission spectra of InQ3 and ZrQ4 in benzonitrile was measured and liquid scintillator cocktail using InQ3 and ZrQ4 (50mg) in benzonitrile solutions (20 mL) with secondary scintillators with PPO (100mg) and POPOP (10mg) was made. The energy spectra of incident gammas were measured, and they are first results of the gamma-ray energy spectra using luminescent of metal complexes.

  19. Separating double-beta decay events from solar neutrino interactions in a kiloton-scale liquid scintillator detector by fast timing

    Science.gov (United States)

    Elagin, Andrey; Frisch, Henry J.; Naranjo, Brian; Ouellet, Jonathan; Winslow, Lindley; Wongjirad, Taritree

    2017-03-01

    We present a technique for separating nuclear double beta decay (ββ -decay) events from background neutrino interactions due to 8B decays in the sun. This background becomes dominant in a kiloton-scale liquid-scintillator detector deep underground and is usually considered as irreducible due to an overlap in deposited energy with the signal. However, electrons from 0 νββ -decay often exceed the Cherenkov threshold in liquid scintillator, producing photons that are prompt and correlated in direction with the initial electron direction. The use of large-area fast photodetectors allows some separation of these prompt photons from delayed isotropic scintillation light and, thus, the possibility of reconstructing the event topology. Using a simulation of a 6.5 m radius liquid scintillator detector with 100 ps resolution photodetectors, we show that a spherical harmonics analysis of early-arrival light can discriminate between 0 νββ -decay signal and 8B solar neutrino background events on a statistical basis. Good separation will require the development of a slow scintillator with a 5 ns risetime.

  20. Counting efficiency for liquid scintillator systems with a single multiplier phototube; Eficiencia de recuento en espectrometros de centelleo con un solo fotomultiplicador

    Energy Technology Data Exchange (ETDEWEB)

    Grau Malonda, A.; Garcia-Torano, E.

    1984-07-01

    In this paper counting efficiency as a function of a free parameter (the figure of merit) has been computed. The results are applicable to liquid scintillator systems with a single multiplier phototube. Tables of counting efficiency for 62 pure beta emitters are given for figures of merit in the range 0.25 to 50. (Author) 16 refs.

  1. Comparison of calculated spectra for the interaction of photons in a liquid scintillator. Example of Mn-54 835 keV emission

    CSIR Research Space (South Africa)

    Cassette, P

    2006-10-01

    Full Text Available methods require the calculation of the energy spectrum absorbed by the liquid scintillator. For radionuclides emitting X-rays or g-rays, when the energy is greater than a few tens of keV the Compton interaction is important and the absorption is not total...

  2. Separating Double-Beta Decay Events from Solar Neutrino Interactions in a Kiloton-Scale Liquid Scintillator Detector By Fast Timing

    CERN Document Server

    Elagin, Andrey; Naranjo, Brian; Ouellet, Jonathan; Winslow, Lindley; Wongjirad, Taritree

    2016-01-01

    We present a technique for separating nuclear double beta decay ($\\beta\\beta$-decay) events from background neutrino interactions due to $^{8}$B decays in the sun. This background becomes dominant in a kiloton-scale liquid-scintillator detector deep underground and is usually considered as irreducible due to an overlap in deposited energy with the signal. However, electrons from 0$\

  3. A simple method to determine bioethanol content in gasoline using two-step extraction and liquid scintillation counting.

    Science.gov (United States)

    Yunoki, Shunji; Saito, Masaaki

    2009-12-01

    A simple method for determining bioethanol content in gasoline containing bioethanol (denoted as E-gasoline in this study) is urgently required. Liquid scintillation counting (LSC) was employed based on the principle that (14)C exists in bioethanol but not in synthetic ethanol. Bioethanol was extracted in two steps by water from E-gasoline containing 3% (E3) or 10% (E10) bioethanol. The (14)C radioactivity was measured by LSC and converted to the amount of bioethanol. The bioethanol content in E-gasoline was determined precisely from the partition coefficient in the extraction and the amount of bioethanol in the water phases: 2.98+/-0.10% for E3 and 10.0+/-0.1% for E10 (means+/-SD; n=3). It appears that this method can be used to determine bioethanol content in E-gasoline quickly and easily.

  4. Attenuation length measurements of a liquid scintillator with LabVIEW and reliability evaluation of the device

    Institute of Scientific and Technical Information of China (English)

    GAO Long; YU Bo-Xiang; DING Ya-Yun; ZHOU Li; WEN Liang-Jian; XIE Yu-Guang; WANG Zhi-Gang

    2013-01-01

    An attenuation length measurement device was constructed using an oscilloscope and LabVIEW for signal acquisition and processing.The performance of the device has been tested in a variety of ways.The test results show that the set-up has a good stability and high precision (sigma/mean reached 0.4 percent).Besides,the accuracy of the measurement system will decrease by about 17 percent if a filter is used.The attenuation length of a gadolinium-loaded liquid scintillator (Gd-LS) was measured as 15.10±0.35 m where Gd-LS was heavily used in the Daya Bay Neutrino Experiment.In addition,one method based on the Beer-Lambert law was proposed to investigate the reliability of the measurement device,the R-square reached 0.9995.Moreover,three purification methods for Linear Alkyl Benzene (LAB) production were compared in the experiment.

  5. Results from a combined test of an electromagnetic liquid argon calorimeter with a hadronic scintillating-tile calorimeter

    CERN Document Server

    Ajaltouni, Ziad J; Alifanov, A; Amaral, P; Ambrosini, G; Amorim, A; Anderson, K J; Astvatsaturov, A R; Aubert, Bernard; Augé, E; Autiero, D; Azuelos, Georges; Badaud, F; Baisin, L; Battistoni, G; Bazan, A; Bee, C P; Bellettini, Giorgio; Berglund, S R; Berset, J C; Blaj, C; Blanchot, G; Blucher, E; Bogush, A A; Bohm, C; Boldea, V; Borisov, O N; Bosman, M; Bouhemaid, N; Brette, P; Bromberg, C; Brossard, M; Budagov, Yu A; Buono, S; Calôba, L P; Camin, D V; Canton, B; Casado, M P; Cavalli, D; Cavalli-Sforza, M; Cavasinni, V; Chadelas, R; Chase, Robert L; Chekhtman, A; Chevaleyre, J C; Chevalley, J L; Chirikov-Zorin, I E; Chlachidze, G; Chollet, J C; Cobal, M; Cogswell, F; Colas, Jacques; Collot, J; Cologna, S; Constantinescu, S; Costa, G; Costanzo, D; Cozzi, L; Crouau, M; Dargent, P; Daudon, F; David, M; Davidek, T; Dawson, J; De, K; de La Taille, C; Del Prete, T; Depommier, P; de Saintignon, P; De Santo, A; Dinkespiler, B; Di Girolamo, B; Dita, S; Dolejsi, J; Dolezal, Z; Downing, R; Dugne, J J; Duval, P Y; Dzahini, D; Efthymiopoulos, I; Errede, D; Errede, S; Etienne, F; Evans, H; Fassnacht, P; Fedyakin, N N; Ferrari, A; Ferreira, P; Ferrer, A; Flaminio, Vincenzo; Fouchez, D; Fournier, D; Fumagalli, G; Gallas, E J; Gaspar, M; Gianotti, F; Gildemeister, O; Gingrich, D M; Glagolev, V V; Golubev, V B; Gómez, A; González, J; Gordon, H A; Grabskii, V; Hakopian, H H; Haney, M; Hellman, S; Henriques, A; Holmgren, S O; Honoré, P F; Hostachy, J Y; Huston, J; Ivanyushenkov, Yu M; Jézéquel, S; Johansson, E K; Jon-And, K; Jones, R; Juste, A; Kakurin, S; Karapetian, G V; Karyukhin, A N; Khokhlov, Yu A; Klioukhine, V I; Kolomoets, V; Kopikov, S V; Kostrikov, M E; Kovtun, V E; Kukhtin, V V; Kulagin, M; Kulchitskii, Yu A; Laborie, G; Lami, S; Lapin, V; Lebedev, A; Lefebvre, M; Le Flour, T; Leitner, R; León-Florián, E; Leroy, C; Le Van-Suu, A; Li, J; Liba, I; Linossier, O; Lokajícek, M; Lomakin, Yu F; Lomakina, O V; Lund-Jensen, B; Mahout, G; Maio, A; Malyukov, S N; Mandelli, L; Mansoulié, B; Mapelli, Livio P; Marin, C P; Marroquin, F; Martin, L; Mazzanti, M; Mazzoni, E; Merritt, F S; Michel, B; Miller, R; Minashvili, I A; Miotto, A; Miralles, L; Mnatzakanian, E A; Monnier, E; Montarou, G; Mornacchi, Giuseppe; Muanza, G S; Nagy, E; Némécek, S; Nessi, Marzio; Nicoleau, S; Noppe, J M; Olivetto, C; Orteu, S; Padilla, C; Pallin, D; Pantea, D; Parrour, G; Pereira, A; Perini, L; Perlas, J A; Pétroff, P; Pilcher, J E; Pinfold, James L; Poggioli, Luc; Poirot, S; Polesello, G; Price, L; Protopopov, Yu; Proudfoot, J; Pukhov, O; Radeka, V; Rahm, David Charles; Reinmuth, G; Renardy, J F; Renzoni, G; Resconi, S; Richards, R; Riu, I; Romanov, V; Ronceux, B; Rumyantsev, V; Rusakovitch, N A; Sala, P R; Sanders, H; Sauvage, G; Savard, P; Savoy-Navarro, Aurore; Sawyer, L; Says, L P; Schaffer, A C; Scheel, C V; Schwemling, P; Schindling, J; Seguin-Moreau, N; Seixas, J M; Selldén, B; Seman, M; Semenov, A A; Senchyshyn, V G; Serin, L; Shchelchkov, A S; Shevtsov, V P; Shochet, M J; Sidorov, V; Simaitis, V J; Simion, S; Sissakian, A N; Solodkov, A A; Sonderegger, P; Soustruznik, K; Stanek, R; Starchenko, E A; Stephani, D; Stephens, R; Studenov, S; Suk, M; Surkov, A; Tang, F; Tardell, S; Tas, P; Teiger, J; Teubert, F; Thaler, J J; Tisserant, S; Tokár, S; Topilin, N D; Trka, Z; Turcot, A S; Turcotte, M; Valkár, S; Vartapetian, A H; Vazeille, F; Vichou, I; Vinogradov, V; Vorozhtsov, S B; Vuillemin, V; Wagner, D; White, Alan R; Wingerter-Seez, I; Yamdagni, N; Yarygin, G; Yosef, C; Zaitsev, A; Zdrazil, M; Zitoun, R; Zolnierowski, Y

    1996-01-01

    The first combined test of an electromagnetic liquid argon accordion calorimeter and a hadronic scintillating-tile calorimeter was carried out at the CERN SPS. These devices are prototypes of the barrel calorimeter of the future ATLAS experiment at the LHC. The energy resolution of pions in the energy range from 20 to 300~GeV at an incident angle $\\theta$ of about 11$^\\circ$ is well-described by the expression $\\sigma/E = ((46.5 \\pm 6.0)\\%/\\sqrt{E} +(1.2 \\pm 0.3)\\%) \\oplus (3.2 \\pm 0.4)~\\mbox{GeV}/E$. Shower profiles, shower leakage, and the angular resolution of hadronic showers were also studied.

  6. Results from a new combined test of an electromagnetic liquid argon calorimeter with a hadronic scintillating-tile calorimeter

    CERN Document Server

    Akhmadaliev, S Z; Amaral, P; Ambrosini, G; Amorim, A; Anderson, K; Andrieux, M L; Aubert, Bernard; Augé, E; Badaud, F; Baisin, L; Barreiro, F; Battistoni, G; Bazan, A; Bazizi, K; Bee, C P; Belorgey, J; Belymam, A; Benchekroun, D; Berglund, S R; Berset, J C; Blanchot, G; Bogush, A A; Bohm, C; Boldea, V; Bonivento, W; Borgeaud, P; Borisov, O N; Bosman, M; Bouhemaid, N; Breton, D; Brette, P; Bromberg, C; Budagov, Yu A; Burdin, S V; Calôba, L P; Camarena, F; Camin, D V; Canton, B; Caprini, M; Carvalho, J; Casado, M P; Cases, R; Castillo, M V; Cavalli, D; Cavalli-Sforza, M; Cavasinni, V; Chadelas, R; Chalifour, M; Chekhtman, A; Chevalley, J L; Chirikov-Zorin, I E; Chlachidze, G; Chollet, J C; Citterio, M; Cleland, W E; Clément, C; Cobal, M; Cogswell, F; Colas, Jacques; Collot, J; Cologna, S; Constantinescu, S; Costa, G; Costanzo, D; Coulon, J P; Crouau, M; Dargent, P; Daudon, F; David, M; Davidek, T; Dawson, J; De, K; Delagnes, E; de La Taille, C; Del Peso, J; Del Prete, T; de Saintignon, P; Di Girolamo, B; Dinkespiler, B; Dita, S; Djama, F; Dodd, J; Dolejsi, J; Dolezal, Z; Downing, R; Dugne, J J; Duval, P Y; Dzahini, D; Efthymiopoulos, I; Errede, D; Errede, S; Etienne, F; Evans, H; Eynard, G; Farida, F; Fassnacht, P; Fedyakin, N N; Fernández de Troconiz, J; Ferrari, A; Ferrer, A; Flaminio, Vincenzo; Fournier, D; Fumagalli, G; Gallas, E J; García, G; Gaspar, M; Gianotti, F; Gildemeister, O; Glagolev, V; Glebov, V Yu; Gómez, A; González, V; González de la Hoz, S; Gordeev, A; Gordon, H A; Grabskii, V; Graugès-Pous, E; Grenier, P; Hakopian, H H; Haney, M; Hébrard, C; Henriques, A; Henry-Coüannier, F; Hervás, L; Higón, E; Holmgren, S O; Hostachy, J Y; Hoummada, A; Huet, M; Huston, J; Imbault, D; Ivanyushenkov, Yu M; Jacquier, Y; Jézéquel, S; Johansson, E K; Jon-And, K; Jones, R; Juste, A; Kakurin, S; Karst, P; Karyukhin, A N; Khokhlov, Yu A; Khubua, J I; Klioukhine, V I; Kolachev, G M; Kolomoets, V; Kopikov, S V; Kostrikov, M E; Kovtun, V E; Kozlov, V; Krivkova, P; Kukhtin, V V; Kulagin, M; Kulchitskii, Yu A; Kuzmin, M V; Labarga, L; Laborie, G; Lacour, D; Lami, S; Lapin, V; Le Dortz, O; Lefebvre, M; Le Flour, T; Leitner, R; Leltchouk, M; Le Van-Suu, A; Li, J; Liapis, C; Linossier, O; Lissauer, D; Lobkowicz, F; Lokajícek, M; Lomakin, Yu F; Lomakina, O V; López-Amengual, J M; Lottin, J P; Lund-Jensen, B; Lundqvist, J M; Maio, A; Makowiecki, D S; Malyukov, S N; Mandelli, L; Mansoulié, B; Mapelli, Livio P; Marin, C P; Marrocchesi, P S; Marroquin, F; Martin, L; Martin, O; Martin, P; Maslennikov, A M; Massol, N; Mazzanti, M; Mazzoni, E; Merritt, F S; Michel, B; Miller, R; Minashvili, I A; Miralles, L; Mirea, A; Mnatzakanian, E A; Monnier, E; Montarou, G; Mornacchi, Giuseppe; Mosidze, M D; Moynot, M; Muanza, G S; Nagy, E; Nayman, P; Némécek, S; Nessi, Marzio; Nicod, D; Nicoleau, S; Niculescu, M; Noppe, J M; Onofre, A; Pallin, D; Pantea, D; Paoletti, R; Park, I C; Parrour, G; Parsons, J; Pascual, J I; Pereira, A; Perini, L; Perlas, J A; Perrodo, P; Petroff, P; Pilcher, J E; Pinhão, J; Plothow-Besch, Hartmute; Poggioli, Luc; Poirot, S; Price, L; Protopopov, Yu; Proudfoot, J; Pukhov, O; Puzo, P; Radeka, V; Rahm, David Charles; Reinmuth, G; Renardy, J F; Renzoni, G; Rescia, S; Resconi, S; Richards, R; Richer, J P; Riu, I; Roda, C; Roldán, J; Romance, J B; Romanov, V; Romero, P; Rusakovitch, N A; Sala, P R; Sanchis, E; Sanders, H; Santoni, C; Santos, J; Sauvage, D; Sauvage, G; Savoy-Navarro, Aurore; Sawyer, L; Says, L P; Schaffer, A C; Schwemling, P; Schwindling, J; Seguin-Moreau, N; Seidl, W; Seixas, J M; Selldén, B; Seman, M; Semenov, A A; Senchyshyn, V G; Serin, L; Shaldaev, E; Shchelchkov, A S; Shochet, M J; Sidorov, V; Silva, J; Simaitis, V J; Simion, S; Sissakian, A N; Soloviev, I V; Snopkov, R; Söderqvist, J; Solodkov, A A; Sonderegger, P; Soustruznik, K; Spanó, F; Spiwoks, R; Stanek, R; Starchenko, E A; Stavina, P; Stephens, R; Studenov, S; Suk, M; Surkov, A; Sykora, I; Taguet, J P; Takai, H; Tang, F; Tardell, S; Tas, P; Teiger, J; Teubert, F; Thaler, J J; Thion, J; Tikhonov, Yu A; Tisserand, V; Tisserant, S; Tokar, S; Topilin, N D; Trka, Z; Turcotte, M; Valkár, S; Varanda, M J; Vartapetian, A H; Vazeille, F; Vichou, I; Vincent, P; Vinogradov, V; Vorozhtsov, S B; Vuillemin, V; Walter, C; White, A; Wielers, M; Wingerter-Seez, I; Wolters, H; Yamdagni, N; Yarygin, G; Yosef, C; Zaitsev, A; Zitoun, R; Zolnierowski, Y

    2000-01-01

    A new combined test of an electromagnetic liquid argon accordion calorimeter and a hadronic scintillating-tile calorimeter was carried out at the CERN SPS. These devices are prototypes of the barrel calorimeter of the future ATLAS experiment at the LHC. The energy resolution of pions in the energy range from 10 to 300 GeV at an incident angle theta of about 12 degrees is well described by the expression sigma /E=((41.9+or-1.6)%/ square root E+(1.8+or-0.1)%)(+) (1.8+or-0.1)/E, where E is in GeV. The response to electrons and muons was evaluated. Shower profiles, shower leakage and the angular resolution of hadronic showers were also studied. Results are compared with those from the previous beam test. (22 refs).

  7. e+/e- discrimination in liquid scintillator and its usage to suppress 8He/9Li backgrounds

    Science.gov (United States)

    Cheng, Ya-Ping; Wen, Liang-Jian; Zhang, Peng; Cao, Xing-Zhong

    2017-01-01

    Reactor neutrino experiments build large-scale detector systems to detect neutrinos. In liquid scintillator, a neutral bound state of a positron and an electron, named positronium, can be formed. The spin triplet state is called ortho-positronium (o-Ps). In this article, an experiment is designed to measure the lifetime of o-Ps, giving a result of 3.1 ns. A PSD parameter based on photon emission time distribution (PETD) was constructed to discriminate e+/e-. Finally, the application of e+/e- discrimination in the JUNO experiment is shown. It helps suppress 8He/9Li backgrounds and improves the sensitivity by 0.6 in χ 2 analysis with an assumption of σ = 1 ns PMT Transit Time Spread, which will bring a smearing effect to the PETD. Supported by National Natural Science Foundation of China (11575226, 11475197, 11205183)

  8. Attenuation length measurements of a liquid scintillator with LabVIEW and reliability evaluation of the device

    Science.gov (United States)

    Gao, Long; Yu, Bo-Xiang; Ding, Ya-Yun; Zhou, Li; Wen, Liang-Jian; Xie, Yu-Guang; Wang, Zhi-Gang; Cai, Xiao; Sun, Xi-Lei; Fang, Jian; Xue, Zhen; Zhang, Ai-Wu; Lü, Qi-Wen; Sun, Li-Jun; Ge, Yong-Shuai; Liu, Ying-Biao; Niu, Shun-Li; Hu, Tao; Cao, Jun; Lü, Jun-Guang

    2013-07-01

    An attenuation length measurement device was constructed using an oscilloscope and LabVIEW for signal acquisition and processing. The performance of the device has been tested in a variety of ways. The test results show that the set-up has a good stability and high precision (sigma/mean reached 0.4 percent). Besides, the accuracy of the measurement system will decrease by about 17 percent if a filter is used. The attenuation length of a gadolinium-loaded liquid scintillator (Gd-LS) was measured as 15.10±0.35 m where Gd-LS was heavily used in the Daya Bay Neutrino Experiment. In addition, one method based on the Beer-Lambert law was proposed to investigate the reliability of the measurement device, the R-square reached 0.9995. Moreover, three purification methods for Linear Alkyl Benzene (LAB) production were compared in the experiment.

  9. The implications of particle energy and acidic media on gross alpha and gross beta determination using liquid scintillation

    Energy Technology Data Exchange (ETDEWEB)

    Zapata-Garcia, D. [Laboratori de Radiologia Ambiental (LRA), Departament de Quimica Analitica, Universitat de Barcelona, Marti i Franques, 1-11 Planta 3, E-08028 Barcelona (Spain); Llaurado, M., E-mail: montse.llaurado@ub.edu [Laboratori de Radiologia Ambiental (LRA), Departament de Quimica Analitica, Universitat de Barcelona, Marti i Franques, 1-11 Planta 3, E-08028 Barcelona (Spain); Rauret, G. [Laboratori de Radiologia Ambiental (LRA), Departament de Quimica Analitica, Universitat de Barcelona, Marti i Franques, 1-11 Planta 3, E-08028 Barcelona (Spain)

    2012-04-15

    The interaction of humans with radioactivity present in the environment from natural and artificial sources necessitates an evaluation of its risk on human health. Gross alpha and gross beta activities can provide a rapid evaluation of the radioactive content of a sample and can be simultaneously determined by using liquid scintillation counters. However, calibration of the liquid scintillation counter is required and is affected by many factors, such as particle energy and the acidity of the media. This study investigates what effect the particle energy used for calibration has on misclassification and how to account for this misclassification in routine measurements. The variability in measurement produced by the final pH, as well as any acids used in sample treatment, was also studied. These results showed that the most commonly used acid for these types of analyses, HNO{sub 3}, produced a high amount of misclassifications at very low pH. The results improved when HCl was used to adjust the sample to low pH. - Highlights: Black-Right-Pointing-Pointer We study the effect of alpha and beta energies on PSA optimisation. Black-Right-Pointing-Pointer The optimum PSA shifts to higher values as the alpha energy increases. Beta energies do not affect it. Black-Right-Pointing-Pointer We study the effect of pH on the simultaneous determination of gross alpha/beta activities. Black-Right-Pointing-Pointer HNO{sub 3} produces a high amount of misclassification at very low pH. Black-Right-Pointing-Pointer The results improve when HCl is used to adjust the sample to low pH.

  10. Liquid scintillation counting efficiency in three photomultiplier systems. Pure electron capture; Eficiencia de recuento por centelleo liquido en sistemas con tres fotomultiplicadores. Captura electronica pura

    Energy Technology Data Exchange (ETDEWEB)

    Los Arcos, J. M.; Grau Carles, A.; Grau Malonda, A.

    1990-07-01

    The tables of counting efficiency as a function of the figure of merit for a liquid scintillation counting system working with three phototubes are presented. The evaluation has been carried out for a Toluene-based scintillator with 5, 10 and 15 ml column, and 19 different radionuclides decaying by pure electron capture: 37Ar 41Ca, 49V, 53 Mn, 55Fe, 59Ni, 68Ge 7iGe, 82Sr, 97Tc, 118Te, 131CS, 137La, 140Ca, 157Tb, 165Er, 193Pt, 194Hg, 205Pb. (Author) 22 refs.

  11. SCINFI, a program to calculate the standardization curve in liquid scintillation counting; SCINFI, un programa para calcular la curva de calibracion eficiencia-extincion en centelleo liquido

    Energy Technology Data Exchange (ETDEWEB)

    Grau Carles, A.; Grau Malonda, A.

    1984-07-01

    A code, SCINFI, was developed, written in BASIC, to compute the efficiency- quench standardization curve for any radionuclide. The program requires the standardization curve for 3H and the polynomial relations between counting efficiency and figure of merit for both 3H and the problem (e.g. 14{sup C}). The program is applied to the computation of the efficiency-quench standardization curve for 14{sup c}. Five different liquid scintillation spectrometers and two scintillator solutions have bean checked. The computation results are compared with the experimental values obtained with a set of 14{sup c} standardized samples. (Author)

  12. Comparison of analysis techniques by liquid scintillation and Cerenkov Effect for {sup 40}K quantification in aqueous samples; Comparacion de las tecnicas de analisis por centelleo liquido y efecto Cerenkov para la cuantificacion {sup 40}K en muestras acuosas

    Energy Technology Data Exchange (ETDEWEB)

    Miranda C, L.; Davila R, J. I.; Lopez del R, H.; Mireles G, F., E-mail: lilimica20@hotmail.com [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas, Zac. (Mexico)

    2015-09-15

    In this work the counting by liquid scintillation and Cerenkov Effect to quantify {sup 40}K in aqueous samples was used. The performance of both techniques was studied by comparing the response of three commercial liquid scintillation OptiPhase HiSafe 3, Ultima Gold Ab and OptiPhase TriSafe, the vial type and presentation conditions of the sample for counting. In liquid scintillation, the ability to form homogeneous mixtures depended on the ionic strength of the aqueous solutions. The scintillator OptiPhase HiSafe 3 showed a greater charge capacity for solutions with high ionic strength (<3.4), while the scintillator OptiSafe TriSafe no form homogeneous mixtures for solutions of ionic strength higher than 0.3. Counting efficiencies for different proportions of sample and scintillator near 100% for the scintillators OptiSafe HiSafe 3 and Ultima Gold Ab were obtained. In the counting by Cerenkov Effect, the efficiency and sensitivity depended of the vial type; polyethylene vials were more suitable for counting that the glass vials. The sample volume had not significant effect on counting efficiency, obtaining an average value of 44.8% for polyethylene vials and 37.3% for glass vials. Therefore, the liquid scintillation was more efficient and sensitive for the measurement of {sup 40}K in aqueous solutions. (Author)

  13. p-Terphenyl: An alternative to liquid scintillators for neutron detection

    Energy Technology Data Exchange (ETDEWEB)

    Sardet, A., E-mail: alix.sardet@cea.fr [CEA, DAM, DIF, F-91297 Arpajon (France); Varignon, C.; Laurent, B.; Granier, T. [CEA, DAM, DIF, F-91297 Arpajon (France); Oberstedt, A. [CEA, DAM, DIF, F-91297 Arpajon (France); Fundamental Physics, Chalmers University of Technology, S-41296 Göteborg (Sweden)

    2015-08-21

    A detailed characterization of doped paraterphenyl (p-Terphenyl) neutron detectors was obtained by means of γ-sources and a {sup 252}Cf fission chamber. The intrinsic timing resolution, the energy resolution up to 2 MeV{sub ee}, and the electron-equivalent energy calibration were determined using γ-sources. The neutron time-of-flight spectrum from the spontaneous fission of {sup 252}Cf provided information on the proton energy calibration, the light output function, and the intrinsic neutron detection efficiency between 0 and 8 MeV for a threshold of 250 keV. Measurements of the latter were also performed using monoenergetic neutron beams. The applied experimental methods were cross-checked using two BC501A scintillation detectors, which were previously calibrated at the Physikalisch-Technische Bundesanstalt in Braunschweig, Germany. Results were compared to Monte-Carlo simulations performed using NRESP7 and NEFF7 codes.

  14. A rapid method for the simultaneous determination of gross alpha and beta activities in water samples using a low background liquid scintillation counter

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez-Cabeza, J.A.; Pujol, Ll. [Universitat Autonoma de Barcelona, Bellaterra (Spain)

    1995-05-01

    The radiological examination of water requires a rapid screening technique that permits the determination of the gross alpha and beta activities of each sample in order to decide if further radiological analyses are necessary. In this work, the use of a low background liquid scintillation system (Quantulus 1220) is proposed to simultaneously determine the gross activities in water samples. Liquid scintillation is compared to more conventional techniques used in most monitoring laboratories. In order to determine the best counting configuration of the system, pulse shape discrimination was optimized for 6 scintillant/vial combinations. It was concluded that the best counting configuration was obtained with the scintillation cocktail Optiphase Hisafe 3 in Zinsser low diffusion vials. The detection limits achieved were 0.012 Bq L{sup -1} and 0.14 Bq L{sup {minus}1} for gross alpha and beta activity respectively, after a 1:10 concentration process by simple evaporation and for a counting time of only 360 min. The proposed technique is rapid, gives spectral information, and is adequate to determine gross activities according to the World Health Organization (WMO) guideline values.

  15. Study of the factors affecting the performance of microextraction by packed sorbent (MEPS) using liquid scintillation counter and liquid chromatography-tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Altun, Zeki [Karlstad University, Faculty of Technology and Science, SE-651 88 Karlstad (Sweden); Abdel-Rehim, Mohamed [Karlstad University, Faculty of Technology and Science, SE-651 88 Karlstad (Sweden); Clinical Pharmacology and DMPK, AstraZeneca R and D Soedertaelje, SE-151 85 Soedertaelje (Sweden)], E-mail: Mohamed.Abdel-Rehim@Astrazeneca.com

    2008-12-23

    Microextraction by packed sorbent (MEPS) is a new technique for sample preparation that can be connected on-line with LC or GC. In MEPS, approximately 1-2 mg of the solid packing material is inserted into a syringe (100-250 {mu}L) as a plug. Sample preparation takes place on the packed bed. The bed can be packed or coated to provide selective and suitable sampling conditions. The new method is very promising for extraction of drugs and metabolites from biological samples. In this paper, some factors affecting the performance of MEPS such as recovery, carry-over, leakage, washing volume and elution volume were studied using C18 and hydroxylated polystyrene-divinylbenzene copolymer (ENV+) as sorbents. Radioactively labelled bupivacaine in plasma samples was used as test analyte. For the extraction of this drug, using methanol/water 95:5 (v/v) (0.25% ammonium hydroxide) was used as elution solvent. The analyte response increased with increasing the elution volume and it was linear upp up to 100 {mu}L utilizing liquid scintillation counter. Further, for concentrating the sample, we found that MEPS may be used such that the sample can be drawn through the needle, up and down, several times. The analyte leakage increases as the volume washing increases, though higher washing volumes may also result in cleaner extracts. To eliminate analyte carry-over, the sorbents were washed first with 3 x 250 {mu}L elution solution and then with 3 x 250 {mu}L washing solution. In addition, the reproducibility measurements show relatively good relative standard deviation (RSD) % values concerning analyte recovery and analyte leakage. The present study provides an understanding of basic aspects when optimizing methods for MEPS. In this study, MEPS was used off-line with liquid scintillation counter and on-line with LC-MS/MS.

  16. Enhancement of archaeological heritage. El Risco de las Cuevas at Perales de Tajuña, Madrid (Spain)

    Science.gov (United States)

    Freire-Lista, David Martin; Alvarez de Buergo, Mónica; Fort, Rafael

    2016-04-01

    Heritage conservation has a great impact on the economy of a country. The enhancement of archaeological sites is an investment that promotes tourism and culture. The interdisciplinary knowledge of heritage should be the basis of its management. Preventive actions, non-destructive analytical techniques and monitoring for the conservation of these assets should be promoted. "El Risco de las Cuevas" is a highly decayed and nearly vertical gypsum escarpment which contains a series of dwellings excavated during the Chalcolithic and much more recent times. It is located at Perales de Tajuña, 40 km southeast of Madrid, Spain. This monument is approximately 70 metres high and 500 metres wide. It was listed as a cultural and monumental heritage site by the regional government of Madrid in 1998. The gypsum escarpment housing the dwellings forms part of a lower Miocene unit (Madrid Basin). Debris cones with a mixture of debris from the lower, medium and upper units are found at the bottom of the rockwall. The vulnerability of this monument to atmospheric agents has been studied using "in situ" monitoring techniques of humidity, temperature and rate of rockfalls. Drones have been used for aerial photography in the highest areas of the escarpment and have provided an information network of fractures likely to cause rockfall. Gypsum artificial accelerated ageing has been carried out in the laboratory, including freeze/thaw, wet/dry, thermal shock and dissolution tests. To determine the response of these accelerated ageing processes, density, micro-roughness, ultrasound velocities (Vp and Vs), air permeability and microscopy measurements were made before, during and after ageing tests. Geomorphological studies, rates of decay, material characteristics and durability tests indicate that the decay is controlled by the mineralogy, clay content and porosity of the gypsum rock, as well as microclimate, temperature changes and rock fractures. Rockfalls are particularly relevant in the

  17. Monitoring gross alpha and beta activity in liquids by using ZnS(Ag) scintillation detectors

    Energy Technology Data Exchange (ETDEWEB)

    Stevanato, L.; Cester, D.; Filippi, D.; Lunardon, M.; Mistura, G.; Moretto, S.; Viesti, G. [Department of Physics and Astronomy ' Galileo Galilei' , University of Padova, (Italy); Badocco, D.; Pastore, P.; Romanini, F. [Department of Chemical Sciences, University of Padova, (Italy)

    2015-07-01

    In this work the possibility of monitoring gross alpha and beta activity in liquids using EJ-444 was investigated. Specific tests were carried out to determine the change of the detector properties in water tests. Possible protecting coating is also proposed and tested. Alpha/beta real-time monitoring in liquids is a goal of the EU project TAWARA{sub R}TM. (authors)

  18. Table-top setup for investigating the scintillation properties of liquid argon

    CERN Document Server

    Heindl, T; Fedenev, A; Hofmann, M; Krücken, R; Oberauer, L; Potzel, W; Wieser, J; Ulrich, A

    2015-01-01

    The spectral and temporal light emission properties of liquid argon have been studied in the context of its use in large liquid rare-gas detectors for detecting Dark Matter particles in astronomy. A table-top setup has been developed. Continuous and pulsed low energy electron beam excitation is used to stimulate light emission. A spectral range from 110 to 1000 nm in wavelength is covered by the detection system with a time resolution on the order of 1 ns.

  19. Validation the quantification of beta emitters activity in urine by scintillation spectrometry in the liquid phase; Validacion de la cuantificacion de actividad de emisores beta en orina mediante espectrometria de centelleo en fase liquida

    Energy Technology Data Exchange (ETDEWEB)

    Sierra, I.; Hernandez, C.; Benito, P.; Lopez, C.

    2013-07-01

    In this paper the methodology used in the validation of the technique for quantifying activity of some beta emitters in urine ({sup 3}H, {sup 1}4C, {sup 3}5S, {sup 3}2P and {sup 9}0Sr) by scintillation spectrometry Liquid Phase (Liquid Scintillation Counting, LSC) is described in bio elimination Laboratory Service CIEMAT Radiation Dosimetry accredited since last year for carrying out assays measure radiation dose based on ISO forth above. (Author)

  20. Standardization of 137mCs+137mBa by Liquid Scintillation; Calibracion de 137Cs+137mBa por Centelleo Liquido

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez, L.; Los Arcos, J.M.; Grau, A.

    1995-07-01

    A procedure for the preparation of a stable, homogeneous solution of 137Cs+''137mBa, for use in liquid scintillation measurements, is described. Its count rate stability and spectral time evolution has been followed for several weeks. The solution has been standardised by the CIEMAT/NIST method in both Ultima-Gold and Insta-Gel, to a combined uncertainty lower than 0,51 % (k=l). (Author) 5 refs.

  1. Intense Vacuum-Ultraviolet and Infrared Scintillation of Liquid Ar-Xe Mixtures

    CERN Document Server

    Neumeier, A; Heindl, T; Himpsl, A; Oberauer, L; Potzel, W; Roth, S; Schönert, S; Wieser, J; Ulrich, A

    2015-01-01

    Vacuum ultraviolet light emission from xenon-doped liquid argon is described in the context of liquid noble gas particle detectors. Xenon concentrations in liquid argon from 0.1 ppm to 1000 ppm were studied. The energy transfer from the second excimer continuum of argon ($\\sim$127 nm) to the second excimer continuum of xenon ($\\sim$174 nm) is observed by recording optical emission spectra. The transfer almost saturates at a xenon concentration of $\\sim$10 ppm for which, in addition, an intense emission in the infrared at a peak wavelength of 1.17 $\\mu$m with (13000$\\pm$4000) photons per MeV deposited by electrons had been found. The corresponding value for the VUV emission at a peak wavelength of 174 nm (second excimer continuum of xenon) is determined to be (20000$\\pm$6000) photons per MeV electron energy deposited. Under these excitation conditions pure liquid argon emits (22000$\\pm$3000) photons per MeV electron energy deposited at a peak wavelength of 127nm. An electron-beam induced emission spectrum for ...

  2. Validation of a procedure for the analysis of (226)Ra in naturally occurring radioactive materials using a liquid scintillation counter.

    Science.gov (United States)

    Kim, Hyuncheol; Jung, Yoonhee; Ji, Young-Yong; Lim, Jong-Myung; Chung, Kun Ho; Kang, Mun Ja

    2017-01-01

    An analytical procedure for detecting (226)Ra in naturally occurring radioactive materials (NORMs) using a liquid scintillation counter (LSC) was developed and validated with reference materials (zircon matrix, bauxite matrix, coal fly ash, and phosphogypsum) that represent typical NORMs. The (226)Ra was released from samples by a fusion method and was separated using sulfate-coprecipitation. Next, a (222)Rn-emanation technique was applied for the determination of (226)Ra. The counting efficiency was 238 ± 8% with glass vials. The recovery for the reference materials was 80 ± 11%. The linearity of the method was tested with different masses of zircon matrix reference materials. Using 15 types of real NORMs, including raw materials and by-products, this LSC method was compared with γ-spectrometry, which had already been validated for (226)Ra analysis. The correlation coefficient for the results from the LSC method and γ-spectrometry was 0.993 ± 0.058.

  3. Magnetic iron oxide nanoparticles for the collection and direct measurement of adsorbed alpha-emitting radionuclides from environmental waters by liquid scintillation analysis

    Energy Technology Data Exchange (ETDEWEB)

    O' Hara, Matthew J.; Addleman, R. Shane

    2017-01-01

    Radioactive contamination in the environment, be it from accidental or intentional release, can create an urgent need to assess water and food supplies, the environment, and monitor human health. Alpha-emitting radionuclides represent the most ionizing, and therefore the most damaging, form of radiation when internalized. Additionally, because of its ease of energy attenuation in solids or liquids, alpha emissions cannot be reliably monitored using non-destructive means. In the event of such an emergency, rapid and efficient methods will be needed to screen scores of samples (food, water, and human excreta) within a short time window. Unfortunately, the assay of alpha-emitting radionuclides using traditional radioanalytical methods is typically labor intensive and time consuming. The creation of analytical counting sources typically requires a series of chemical treatment steps to achieve well performing counting sources. In an effort to devise radioanalytical methods that are fast, require little labor, and minimize the use of toxic or corrosive agents, researchers at PNNL have evaluated magnetite (Fe3O4) nanoparticles as extracting agents for alpha-emitting radionuclides from chemically unmodified aqueous systems. It is demonstrated that bare magnetic nanoparticles exhibit high affinity for representative α-emitting radionuclides (241Am and 210Po) from representative aqueous matrices: river and ground water. Furthermore, use of the magnetic properties of these materials to concentrate the sorbed analyte from the bulk aqueous solution has been demonstrated. The nanoparticle concentrate can be either directly dispensed into scintillation cocktail, or first dissolved and then added to scintillation cocktail as a solution for alpha emission assay by liquid scintillation analysis. Despite the extreme quench caused by the metal oxide suspensions, the authors have demonstrated that quench correction features available on modern liquid scintillation analyzers can be

  4. A measurement of the time profile of scintillation induced by low energy gamma-rays in liquid xenon with the XMASS-I detector

    CERN Document Server

    Takiya, H; Hiraide, K; Ichimura, K; Kishimoto, Y; Kobayashi, K; Kobayashi, M; Moriyama, S; Nakahata, M; Norita, T; Ogawa, H; Sekiya, H; Takachio, O; Takeda, A; Tasaka, S; Yamashita, M; Yang, B S; Kim, N Y; Kim, Y D; Itow, Y; Kegasa, R; Kobayashi, K; Masuda, K; Fushimi, K; Martens, K; Suzuki, Y; Fujita, R; Hosokawa, K; Miuchi, K; Oka, N; Onishi, Y; Takeuchi, Y; Kim, Y H; Lee, J S; Lee, K B; Lee, M K; Fukuda, Y; Nishijima, K; Nakamura, S

    2016-01-01

    We report the measurement of the emission time profile of scintillation from gamma-ray induced events in the XMASS-I 832 kg liquid xenon scintillation detector. Decay time constant was derived from a comparison of scintillation photon timing distributions between the observed data and simulated samples in order to take into account optical processes such as absorption and scattering in liquid xenon. Calibration data of radioactive sources, $^{55}$Fe, $^{241}$Am, and $^{57}$Co were used to obtain the decay time constant. The decay time constant $\\tau$ increased from 27.9 ns to 37.0 ns as the gamma-ray energy increased from 5.9 keV to 122 keV. The accuracy of the measurement was better than 1.5 ns at all energy levels. Furthermore, a fast decay component with $\\tau \\sim$2 ns was necessary to reproduce data. The obtained data almost reproduced previously reported data and extended it to the lower energy region relevant to the direct dark matter search.

  5. A measurement of the time profile of scintillation induced by low energy gamma-rays in liquid xenon with the XMASS-I detector

    Science.gov (United States)

    Takiya, H.; Abe, K.; Hiraide, K.; Ichimura, K.; Kishimoto, Y.; Kobayashi, K.; Kobayashi, M.; Moriyama, S.; Nakahata, M.; Norita, T.; Ogawa, H.; Sekiya, H.; Takachio, O.; Takeda, A.; Tasaka, S.; Yamashita, M.; Yang, B. S.; Kim, N. Y.; Kim, Y. D.; Itow, Y.; Kegasa, R.; Kobayashi, K.; Masuda, K.; Fushimi, K.; Martens, K.; Suzuki, Y.; Fujita, R.; Hosokawa, K.; Miuchi, K.; Oka, N.; Onishi, Y.; Takeuchi, Y.; Kim, Y. H.; Lee, J. S.; Lee, K. B.; Lee, M. K.; Fukuda, Y.; Nishijima, K.; Nakamura, S.

    2016-10-01

    We report the measurement of the emission time profile of scintillation from gamma-ray induced events in the XMASS-I 832 kg liquid xenon scintillation detector. Decay time constant was derived from a comparison of scintillation photon timing distributions between the observed data and simulated samples in order to take into account optical processes such as absorption and scattering in liquid xenon. Calibration data of radioactive sources, 55Fe, 241Am, and 57Co were used to obtain the decay time constant. Assuming two decay components, τ1 and τ2, the decay time constant τ2 increased from 27.9 ns to 37.0 ns as the gamma-ray energy increased from 5.9 keV to 122 keV. The accuracy of the measurement was better than 1.5 ns at all energy levels. A fast decay component with τ1 ∼ 2 ns was necessary to reproduce data. Energy dependencies of τ2 and the fraction of the fast decay component were studied as a function of the kinetic energy of electrons induced by gamma-rays. The obtained data almost reproduced previously reported results and extended them to the lower energy region relevant to direct dark matter searches.

  6. Neutron-Gamma Pulse Shape Discrimination with a NE-213 Liquid Scintillator by Using Digital Signal Processing Combined with Similarity Method

    Directory of Open Access Journals (Sweden)

    Mardiyanto

    2008-07-01

    Full Text Available Neutron-Gamma Pulse Shape Discrimination with a NE-213 Liquid Scintillator by Using Digital Signal Processing Combined with Similarity Method. Measurement of mixed neutron-gamma radiation is difficult because a neuclear detector is usually sensitive to both radiations. A new attempt of neutron-gamma pulse shape discrimination for a NE-213 liquid scintillator is presented by using digital signal processing combined with an off-line similarity method. The output pulse shapes are digitized with a high speed digital oscilloscope. The n-γ discrimination is done by calculating the index of each pulse shape, which is determined by the similarity method, and then fusing it with its corresponding pulse height. Preliminary results demonstrate good separation of neutron and gamma-ray signals from a NE-213 scintillator with a simple digital system. The results were better than those with a conventional rise time method. Figure of Merit is used to determine the quality of discrimination. The figure of merit of the discrimination using digital signal processing combined with of line similarity method are 1.9; 1.7; 1.1; 1.1; and 0.8 ; on the other hand by using conventional method the rise time are 0.9; 0.9; 0.9; 0.7; and 0.4 for the equivalent electron energy of 800 ; 278 ; 139 ; 69 ; and 30 keV

  7. Development of a liquid scintillation method for in vitro determination of {sup 226}Ra and {sup 228} Ra in bioassay samples

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, Paulo Cesar P.; Sousa, Wanderson O.; Juliao, Ligia M.Q.C.; Dantas, Bernardo M., E-mail: pcesar@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2011-07-01

    Radium isotopes are dispersed in the environment according to their physicochemical characteristics. The intake of {sup 226}Ra and {sup 228}Ra in humans can occur by inhalation and ingestion and the risk of internal exposure are related to their long half-lives, characteristics of the emission and biokinetics of the isotopes in the human body. The goal of this work is to develop a methodology for the analysis of {sup 226}Ra and {sup 228}Ra in excreta samples (urine and feces), using liquid scintillation technique. Excreta samples were provided by non-exposed humans for the purpose of standardizing the methodology and the establishment of a background level of radium excretion. Radium isotopes were concentrated and separated from the constituents of the sample by co-precipitation with barium sulphate. The precipitate of Ba(Ra)SO{sub 4} was filtrated and weighted for the determination of the chemical yield. The filter containing the precipitate was transferred to a scintillation vial. In the scintillation vial, 8 mL of water, 8 mL of Instagel XF and 4 mL of UltimaGold were added, forming a gel suspension, after stirring the solution. The {sup 226}Ra and {sup 228}Ra activities were determined 21 days after the precipitation of samples. The samples were counted in a liquid scintillation spectrometer. The technique presented adequate sensitivity and reproducibility for the analysis of urine and feces. The activities of {sup 226}Ra and {sup 228}Ra in excreta samples provide useful information for the identification of the main route of intake and for the assessment of the internal exposure of occupationally exposed workers and inhabitants of high background areas. (author)

  8. The study of vial and cocktail for tritium radioactivity analysis of rain water by liquid scintillation counter

    Energy Technology Data Exchange (ETDEWEB)

    Noh, Sung Jin; Kim, Hyo Jin; Kim, Hyun; Lee, Man Woo; Jeong, Dong Hyeok; Yang, Kwang Mo; Kang, Yeong Rok [Research Center, Dongnam Institute of Radiological and Medical Sciences, Busan (Korea, Republic of); Nam, Sang Hee [Dept. of Biomedical Engineering, Inje University, Gimhae (Korea, Republic of)

    2015-10-15

    Even though the current method for tritium (3H) analysis is routine, for the case of the low level of tritium in the environment, special conditions have to be fulfilled in order to obtain accurate and reliable tritium measurements. There are very little comparative data concerning commercial scintillating cocktails. The best cocktails for measuring tritium are those based on benzene derived solvent, and the worse cocktails are those which have complex chemical composition or contain too small concentration of scintillators. The aim of study was to investigate various vials and cocktails by comparison with the combination of few different scintillation cocktails and vials in our routine measurements according to count, efficiency, and the figure of merit (FOM). The comparison of three types of vials with scintillation cocktails for tritium activity analysis of rain water shows that glass vials have higher count rates and HiSafe 3 cocktails have lower FOM.

  9. Comparison of the quantulus 1220 and 300SL liquid scintillation counters for the analysis of {sup 222}Rn in groundwater

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Cheol; Jung, Yoon Hee; Lee, Wanno; Choi, Guen Sik; Chung, Kun Ho; Kang, Mun Ja [Environmental Radioactivity Assessment Team, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-12-15

    Liquid scintillation counters (LSCs) are commonly used as an analytical method for detecting {sup 222}Rn in groundwater because they involve a simple sample pretreatment and allow high throughout with an autosampler. The Quantulus 1220 is the best-selling LSC in Korea, but its production was stopped. Recently, a new type of LSC, the 300SL, was introduced. In this study, the 300SL was compared with the Quantulus 1220 in order to evaluate the ability of each apparatus to detect {sup 222}Rn in groundwater. The Quantulus 1220 and 300SL were used to detect the presence of {sup 222}Rn. Radon gas was extracted from a groundwater sample using a water-immiscible cocktail in a LSC vial. The optimal analytical conditions for each LSC were determined using a {sup 222}Rn calibration source prepared with a {sup 226}Ra source. The optimal pulse shape analysis level for alpha and beta separation was 80 for the Quantulus 1220, and the corresponding pulse length index was 12 in the 300SL. The counting efficiency of the Quantulus 1220 for alpha emissions was similar to that of the 300SL, but the background count rate of the Quantulus 1220 was 10 times lower than that of the 300SL. The minimum detectable activity of the Quantulus 1220 was 0.08 Bq·L{sup -,} while that of the 300SL was 0.20 Bq·L{sup -1}. The analytical results regarding {sup 222}Rn in groundwater were less than 10% different between these LSCs. The 300SL is an LSC that is comparable to the Quantulus 1220 for detecting {sup 222}Rn in groundwater. Both LSCs can be applied to determine the levels of {sup 222}Rn in groundwater under the management of the Ministry of Environment.

  10. Analytical method of Kr-85 determination, using cryogenic concentration and separation and liquid scintillation counting; Desarrollo del metodo de concentracion y se paracion criogenica cromatografica y medida radiactiva por centelleo liquido de Kr-85

    Energy Technology Data Exchange (ETDEWEB)

    Heras, M. C.; Perez, M. M.; Grau, A.

    1983-07-01

    The method used in the Laboratory of the JEN for the determination of Kr-85 levels in gaseous effluents of nuclear power and in the atmosphere is described. Samples of air, collected in metallic cylinders, are introduced into a gas-solid chromatographic separation system which resolves Kr from the other air components. The separated Kr ia dissolved in a toluene based scintillation cocktail, and the Kr-85 content is determined by liquid scintillation counting. (Author)

  11. Sensitivity and uncertainty analysis of the simulation of 123I and 54Mn gamma and X-ray emissions in a liquid scintillation vial.

    Science.gov (United States)

    Bignell, L J; Mo, L; Alexiev, D; Hashemi-Nezhad, S R

    2010-01-01

    Radiation transport simulations of the most probable gamma- and X-ray emissions of (123)I and (54)Mn in a three photomultiplier tube liquid scintillation detector have been carried out. A Geant4 simulation was used to acquire energy deposition spectra and interaction probabilities with the scintillant, as required for absolute activity measurement using the triple to double coincidence ratio (TDCR) method. A sensitivity and uncertainty analysis of the simulation model is presented here. The uncertainty in the Monte Carlo simulation results due to the input parameter uncertainties was found to be more significant than the statistical uncertainty component for a typical number of simulated decay events. The model was most sensitive to changes in the volume of the scintillant. Estimates of the relative uncertainty associated with the simulation outputs due to the combined stochastic and input uncertainties are provided. A Monte Carlo uncertainty analysis of an (123)I TDCR measurement indicated that accounting for the simulation uncertainties increases the uncertainty of efficiency of the logical sum of double coincidence by 5.1%. Copyright 2009 Elsevier Ltd. All rights reserved.

  12. Measurement of the scintillation time spectra and pulse-shape discrimination of low-energy β and nuclear recoils in liquid argon with DEAP-1

    Science.gov (United States)

    Amaudruz, P.-A.; Batygov, M.; Beltran, B.; Bonatt, J.; Boudjemline, K.; Boulay, M. G.; Broerman, B.; Bueno, J. F.; Butcher, A.; Cai, B.; Caldwell, T.; Chen, M.; Chouinard, R.; Cleveland, B. T.; Cranshaw, D.; Dering, K.; Duncan, F.; Fatemighomi, N.; Ford, R.; Gagnon, R.; Giampa, P.; Giuliani, F.; Gold, M.; Golovko, V. V.; Gorel, P.; Grace, E.; Graham, K.; Grant, D. R.; Hakobyan, R.; Hallin, A. L.; Hamstra, M.; Harvey, P.; Hearns, C.; Hofgartner, J.; Jillings, C. J.; Kuźniak, M.; Lawson, I.; La Zia, F.; Li, O.; Lidgard, J. J.; Liimatainen, P.; Lippincott, W. H.; Mathew, R.; McDonald, A. B.; McElroy, T.; McFarlane, K.; McKinsey, D. N.; Mehdiyev, R.; Monroe, J.; Muir, A.; Nantais, C.; Nicolics, K.; Nikkel, J.; Noble, A. J.; O'Dwyer, E.; Olsen, K.; Ouellet, C.; Pasuthip, P.; Peeters, S. J. M.; Pollmann, T.; Rau, W.; Retière, F.; Ronquest, M.; Seeburn, N.; Skensved, P.; Smith, B.; Sonley, T.; Tang, J.; Vázquez-Jáuregui, E.; Veloce, L.; Walding, J.; Ward, M.

    2016-12-01

    The DEAP-1 low-background liquid argon detector was used to measure scintillation pulse shapes of electron and nuclear recoil events and to demonstrate the feasibility of pulse-shape discrimination down to an electron-equivalent energy of 20 keVee. In the surface dataset using a triple-coincidence tag we found the fraction of β events that are misidentified as nuclear recoils to be cross-section sensitivity of 10-46 cm2, assuming negligible contribution from nuclear recoil backgrounds.

  13. [Comparative analysis of two diffusion methods for radon Rn-222 estimation in atmospheric air by means of gamma ray spectrometry and liquid scintillation counting].

    Science.gov (United States)

    Gorzkowski, B; Pachocki, K; Peńsko, J; Majle, T; Rózycki, Z

    1995-01-01

    The comparative measurements of radon Rn-222 concentration in indoor air of some buildings and in radon labour chamber have been conducted using two different diffusions methods. The results of parallel measurements using radon charcoal detectors and gamma-rays spectrometry with liquid alpha scintillation counting (Pico-Rad) have been presented. It was concluded that both methods offer the similar measurements possibilities of radon concentrations in the air from about 30 Bq/m3 to about 600 Bq/m3 with the real average divergence between both methods of about +/- 11%.

  14. A high-rate sup 1 sup 0 B-loaded liquid scintillation detector for parity-violation studies in neutron resonances

    CERN Document Server

    Yen Yi Fen; Bolton, R D; Crawford, B E; Delheij, P P J; Hart, G W; Haseyama, T; Frankle, C M; Iinuma, M; Knudson, J N; Masaike, A; Masuda, Y; Matsuda, Y; Mitchell, G E; Penttilae, S I; Roberson, N R; Seestrom, S J; Sharapov, E I; Shimizu, H M; Smith, D A; Stephenson, S L; Szymanski, J J; Yoo, S H; Yuan, V W

    2000-01-01

    We have developed a large-area sup 1 sup 0 B-loaded liquid scintillation detector for parity-violation studies in neutron resonances with high instantaneous neutron fluxes from the LANSCE short-pulse spallation source. The detector has an efficiency of 95%, 85% and 71% at neutron energies of 10, 100 and 1000 eV, respectively. The neutron mean capture time in the detector is (416+-5) ns. We describe the detector and the current-mode signal processing system, that can handle neutron rates up to 500 MHz.

  15. Deuterated-xylene (xylene-d{sub 10}; EJ301D): A new, improved deuterated liquid scintillator for neutron energy measurements without time-of-flight

    Energy Technology Data Exchange (ETDEWEB)

    Becchetti, F.D.; Raymond, R.S.; Torres-Isea, R.O. [Department of Physics, University of Michigan, Ann Arbor, MI 48109 (United States); Di Fulvio, A.; Clarke, S.D.; Pozzi, S.A. [Department of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, MI 48109 (United States); Febbraro, M. [Oak Ridge National Laboratory, Oak Ridge, TN 37830 (United States)

    2016-06-01

    In conjunction with Eljen Technology, Inc. (Sweetwater,TX) we have designed, constructed, and evaluated a 3 in. ×3 in. deuterated-xylene organic liquid scintillator (C{sub 8}D{sub 10}; EJ301D) as a fast neutron detector. Similar to deuterated benzene (C{sub 6}D{sub 6}; NE230, BC537, and EJ315) this scintillator can provide good pulse-shape discrimination between neutrons and gamma rays, has good timing characteristics, and can provide a light spectrum with peaks corresponding to discrete neutron energy groups up to ca. 20 MeV. Unlike benzene-based detectors, deuterated xylene is less volatile, less toxic, is not known to be carcinogenic, has a higher flashpoint, and hence is much safer for many applications. In addition EJ301D can provide slightly more light output and better PSD than deuterated-benzene scintillators. We show that, as with deuterated-benzene scintillators, the light-response spectra can be unfolded to provide useable neutron energy spectra without need for time-of-flight (ToF). An array of these detectors arranged at many angles close to a reaction target can be much more effective (×10 to ×100 or more) than an array of long-path ToF detectors which must utilize a narrowly-bunched and pulse-selected beam. As we demonstrate using a small Van de Graaff accelerator, measurements can thus be performed when a bunched and pulse-selected beam (as needed for time-of-flight) is not available.

  16. Electro-removal of H-3 and C-14 contained in scintillation liquid absorbed in soils type Phaeozem; Electrorremocion de H-3 y C-14 contenidos en liquido de centelleo absorbidos en suelos tipo Phaeozem

    Energy Technology Data Exchange (ETDEWEB)

    Valdovinos, V.; Bustos, E. [Centro de Investigacion y Desarrollo Tecnologico en Electroquimica, Parque Tecnologico Queretaro s/n, San Fandila, 76703 Pedro Escobedo, Queretaro (Mexico); Monroy G, F., E-mail: vvaldovinos@cideteq.mx [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2014-10-15

    This paper presents the results of electro-removal, an electrochemical treatment in soils contaminated with H-3 and C-14 contained in scintillation liquids absorbed in soils. For this purpose the best electrochemical conditions were used, which are: scintillation liquid Ultima Gold Xr, water (1:1) and 1 m A in the passage of current. The media were characterized before and after of applying the different potentials by various analytical techniques, such as: liquids by gas chromatography with a flame ionization detector, solids and liquids by Fourier transform infrared spectroscopy (Ftir) and electrodes by scanning electron microscopy with elemental analysis by energy-dispersive X-ray spectroscopy. Later standard samples with H-3 and C-14 were prepared and the electrochemical treatment was applied to previously established conditions. After electrochemical treatment the scintillation liquid characterization was performed by gas chromatography and a scintillation counter to see the disintegrations per minute. According to results of Ftir, soils show no deterioration and in the liquid phase the amount of water increases as the applied potential, due to oxidation-reduction reactions where happen modification or mineralization of organic molecules (H{sub 2}O and CO{sub 2} formation). In 4 h of treatment, removal percentages in the liquid phase, were: 53.6% of H-3 and 11.6% of C-14. (Author)

  17. Microfluidic Scintillation Detectors

    CERN Multimedia

    Microfluidic scintillation detectors are devices of recent introduction for the detection of high energy particles, developed within the EP-DT group at CERN. Most of the interest for such technology comes from the use of liquid scintillators, which entails the possibility of changing the active material in the detector, leading to an increased radiation resistance. This feature, together with the high spatial resolution and low thickness deriving from the microfabrication techniques used to manufacture such devices, is desirable not only in instrumentation for high energy physics experiments but also in medical detectors such as beam monitors for hadron therapy.

  18. Evaluation of different parameters affecting the liquid scintillation spectrometry measurement of gross alpha and beta index in water samples

    Energy Technology Data Exchange (ETDEWEB)

    Palomo, M. [Unitat de Radioquimica Ambiental i Sanitaria, Universitat Rovira i Virgili, Tarragona (Spain); Villa, M. [Centro de Investigacion, Tecnologia e Innovacion. Servicio Radioisotopos. Universidad de Sevilla (Spain); Casacuberta, N. [Institut de Ciencia i Tecnologia Ambientals-Departament de Fisica, Universitat Autonoma de Barcelona. Spain (Spain); Penalver, A.; Borrull, F. [Unitat de Radioquimica Ambiental i Sanitaria, Universitat Rovira i Virgili, Tarragona (Spain); Aguilar, C., E-mail: carme.aguilar@urv.cat [Unitat de Radioquimica Ambiental i Sanitaria, Universitat Rovira i Virgili, Tarragona (Spain)

    2011-09-15

    Liquid scintillation spectrometry is a fast competitive technique for the simultaneous evaluation of gross alpha and beta indexes. However, the implementation of this technique should not be considered as straightforward, and the pre-concentration methods to decrease the detection limit together with quenching and alpha, and beta crossover corrections should be carefully chosen according to the needs of the laboratory. Both aspects are being approached in this work as to find an easy and robust method for alpha/beta measurement in water samples, taking into account the quenching and alpha/beta crossover interferences effects. Results showed that most of the pre-concentration methods increased the quenching in the measurement, although HNO{sub 3} 0.05 M points to be the best solution for pre-concentration and re-dissolution of the sample as converges into low quenching and maximum recovery. Subsequently, in the measurement of water samples with different conductivities, the analysis of the raw counts to obtain gross alpha and beta indexes was carried out using different approaches to implement quenching and interference corrections. If quenching and salt content in the sample are relatively low, interference and quenching-efficiency corrections do not improve the accuracy of the results within the usual precision assumed for a result of gross alpha and beta index (25%). Special attention must be paid when corrections are applied to high quenched or saline samples and when alpha and beta activities values are different in several orders of magnitude. - Highlights: > Developed method for simultaneously quantifying gross alpha and gross beta indexes based on LSC was as accurate and precise as the results obtained from methods based on gas proportional counting and ZnS alpha counting. > Alpha/beta crossover and/or quenching corrections were applied and the results obtained did not improve accuracy within 25% dispersion, a widespread acceptance limit for gross alpha and

  19. Determination of the 10Be half-life by multicollector ICP-MS and liquid scintillation counting

    Science.gov (United States)

    Chmeleff, Jérôme; von Blanckenburg, Friedhelm; Kossert, Karsten; Jakob, Dieter

    2010-01-01

    A new method was designed and used for determining the half-life of the isotope 10Be. The method is based on (1) accurate 10Be/ 9Be measurements of 9Be-spiked solutions of a 10Be-rich master solution using multicollector ICP mass spectrometry (MC-ICP-MS) and (2) liquid scintillation counting (LSC) using the CIEMAT/NIST method for determining the activity concentrations of the solutions whose 10Be concentrations were determined by mass spectrometry. Important requirements for the success of this approach (a) was the previous coating of glass ampoules filled for counting experiments with 9Be, thereby reducing the risk of the adsorptive loss of 10Be; (b) the removal of Boron from solutions to be measured by MC-ICP-MS by cation chromatography without the introduction of mass fractionation and (c) the accurate determination of the mass bias of 10Be/ 9Be measurements by ICP-MS which are always affected by the space-charge effect. The mass bias factor was determined to be 1.1862 ± 0.071 for 10Be/ 9Be from careful fitting and error propagation of ratios of measured Li, B, Si, Cr, Fe, Cu, Sr, Nd, Hf, Tl and U standard solutions of known composition under the same measurement conditions. Employing this factor, an absolute 10Be/ 9Be ratio of 1.464 ± 0.014 was determined for a first dilution of the 10Be-rich master solution. This solution is now available as an absolute Be ratio standard in AMS measurements. Finally, a half-life of (1.386 ± 0.016) My (standard uncertainty) was calculated. This value is much more precise than previous estimates and was derived from a fully independent set of experiments. In a parallel, fully independent study using the same master solution, Korschinek et al. [35] have determined a half-life of (1.388 ± 0.018) My. The combined half-life and uncertainty amounts to (1.387 ± 0.012) My. We suggest the use of this value in nuclear studies and in studies that make use of cosmogenic 10Be in environmental and geologic samples.

  20. Measurement of radon on Misasa district, Tottori pref. using the PICO-RAD detector and a liquid scintillation spectrometer. 3

    Energy Technology Data Exchange (ETDEWEB)

    Koga, Taeko; Inagaki, Masayo; Morishima, Hiroshige; Tanaka, Yuki [Kinki Univ., Higashi-Osaka, Osaka (Japan). Atomic Energy Research Inst.; Nakanishi, Akihiro; Sasaki, Noriko; Mifune, Masaaki

    1996-12-01

    By means of a radon detecting device (Packard Pico-Rad System) using absorbed active charcoal and a liquid scintillation spectrometer, studies on environmental movements of radon and its decay nuclides on Misasa district in Tottori pref. were done continuously on last year. Its minimum detection limits of radon in the air are 1.7Bq/m{sup 3} and 0.43Bq/l in the water on counting time of 200 minutes. This method is able to measure conveniently and rapidly on sampling period for 24 hours. (1) Radon concentrations in the air at Misasa environs area on October and November, 1995 were ranged 7.7-59Bq/m{sup 3} in outdoor and 13-141Bq/m{sup 3} in indoor. On the results measured on Misasa area, {sup 222}Rn concentrations on Asahi district located southward from Misasa spa district and Takeda district along Tenjin stream are high, on Kojika district located east-southward from Misasa spa district and Mitoku district are low and outdoor {sup 222}Rn concentrations on Ningyo toge neighboring are low level with ranged 12-31Bq/m{sup 3}. Indoor {sup 222}Rn concentrations at Takeda district are about 4 times higher than Kojika district showed the lowest concentration and those of Kojika district are almost similar to those of Higashi Osaka. Indoor {sup 222}Rn concentration are higher than outdoor, the mean ratio of indoor to outdoor {sup 222}Rn concentration on a few sample of Takeda and Asahi districts (upper stream) are about 2 and those on the other district are shown in low tendency ranged 1-1.3. There are a few difference among some districts. (2) {sup 222}Rn concentration variations in a dwelling at Misasa spa district were observed from May to December 1995 in the time course. They are varied in range of 53-121Bq/m{sup 3} indoor, 9-50Bq/m{sup 3} outdoor and 48-188Bq/m{sup 3} in bathroom. (3) {sup 222}Rn concentration variations in water samples at Misasa spa district are 91-161Bq/l in hot spring, 2.3-10Bq/l in river water and 14-34Bq/l in well water from May to December 1995

  1. A comparison between the measurements of Kr-85 in environmental samples by liquid scintillation and proportional counters; Comparacion de resultados de la medida radiactiva del Kr-85 ambiental por centelleo liquido y contadores proporcionales

    Energy Technology Data Exchange (ETDEWEB)

    Heras, M. C.; Perez, M. M.

    1983-07-01

    The most used methods for the measurement of Kr-81 beta-activity after their concentration and aisolation are the liquid scintillation counting and the proportional counter. In this work the beta activity of concentrated and aisolated Kr-85 samples measured in collaboration with the Max-Planck Institut fur Kernphyslk, Aussenstelle Freiburg. Samples taken both In Madrid and Frelburg are measured by proportional counters in the Max-Planck lnstitut, Freibury and by liquid scintillation counting in JEN, Madrid. The comparison of both measurements do not show appreciable discrepancy between the results obtained to both techniques. (Author)

  2. Performance of two liquids scintillation and optimization of a Wallac 1411 counter in the tritium quantification in aqueous samples; Desempeno de dos centelleadores liquidos y optimizacion de un contador Wallac 1411 en la cuantificacion de tritio en muestras acuosas

    Energy Technology Data Exchange (ETDEWEB)

    Contreras de la Cruz, E. de J.; Lopez del Rio, H.; Davila R, J. I.; Mireles G, F.; Pinedo V, J. L., E-mail: hlopezdelrio@hotmail.com [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico)

    2014-10-15

    The optimization of a liquid scintillation counting Wallac 1411 is presented as well as the performance of the liquids scintillation miscible in water OptiPhase Hi Safe 3 and Last Gold Ab, in the tritium quantification in aqueous samples. The luminescence effect, the quenching, the solution ph and the level of pulse amplitude comparator (Pac) were evaluated in the response of both liquids scintillation in the tritium measurement. The quenching and the luminescence modify the scintillators response; in the first of them the counting efficiency decreases and the minimum detectable activity increases; the second interferes in the tritium quantification in the interest window, but the effect disappears after 4 hours of darkness of the samples. The maximum counting efficiency was of 24% for OptiPhase Hi Safe 3 and 31% for Last Gold Ab, diminishing with the quenching until values of 8 and 11%, respectively. For a counting time of 6 hours and lower quenching, the minimum detectable concentration for OptiPhase Hi Safe 3 was of 13.4 ± 0.2 Bq/L and 9.9 ± 0.1 Bq/L for Last Gold Ab. Both scintillators responded appropriately to sour and basic solutions, being only presented chemiluminescence in Last Gold Ab to ph highly basic. The Pac application that varies between 1 and 256 does not have effect in the tritium measurement until values above 90. (Author)

  3. Topological track reconstruction in liquid scintillator and LENA as a far-detector in an LBNO experiment

    Energy Technology Data Exchange (ETDEWEB)

    Lorenz, Sebastian

    2016-12-15

    Unsegmented liquid scintillator (LSc) neutrino detectors have proven to be successful instruments of neutrino physics. They usually measure terrestrial and astrophysical low-energy (LE) neutrinos and antineutrinos with energies up to some tens of MeV. Designs for next-generation detectors based on this technology intend to use several tens of kilotons of LSc. Two examples are the Low Energy Neutrino Astronomy (LENA) project with 50 kt considered in Europe and the Jiangmen Underground Neutrino Observatory (JUNO) with 20 kt already under construction in China. A key factor to reach the scientific goals of these projects, e.g., the determination of the neutrino mass ordering (MO) in the case of JUNO, will be the efficient rejection of background from radioisotopes produced by cosmogenic muons. This requires accurate reconstructions of extended muon event topologies in the LSc volume.The first part of this work is about the implementation of a novel, iterative track reconstruction procedure for unsegmented LSc detectors and a basic evaluation of its performance with the LENA detector simulation. The ultimate goal of the new method is to reconstruct the spatial number density distribution of optical photon emissions. This will give access to a charged particle's differential energy loss dE/dx in LSc and resolve details of an event's topology, e.g., induced particle showers. Visual comparisons of reconstruction outcomes with Monte Carlo (MC) truths already provide evidence for this capability. First quantitative results were extracted from the 3D reconstruction data of fully-contained muons in the kinetic energy range from 1 to 10 GeV: Despite some well understood systematic effects in the current method to find start and end point of a track, resolutions

  4. Determination of {sup 125}I impurities in [{sup 123}I]labelled radiopharmaceuticals, by liquid scintillation counting: sensitivity of the method

    Energy Technology Data Exchange (ETDEWEB)

    Bonardi, M.L. E-mail: mauro.bonardi@mi.infn.itmauro.bonari@mi.infn.it; Birattari, C.; Groppi, F.; Gini, L.; Mainardi, C.H.S.; Menapace, E

    2004-01-01

    Iodine-125 is a radioisotopic impurity 'always' present in iodine-123, produced by nuclear reactions induced either on natural or 'highly' enriched targets. Liquid scintillation counting is a very sensitive tool to determine low level impurities of both low energy electrons and photons in aqueous and organic solutions of radiopharmaceutical compounds. With this technique it was possible to determine, on commercial samples, that the content of {sup 125}I was of the order of not less than 0.1% for {sup 123}I produced via {sup 127}I(p,5n) reactions and not less than 0.01% for {sup 123}I produced via 'highly' enriched {sup 124}Xe(p,X) nuclear reactions.

  5. Measurements of high energy neutrons penetrated through iron shields using the Self-TOF detector and an NE213 organic liquid scintillator

    CERN Document Server

    Sasaki, M; Nunomiya, T; Nakamura, T; Fukumura, A; Takada, M

    2002-01-01

    Neutron energy spectra penetrated through iron shields were measured using the Self-TOF detector and an NE213 organic liquid scintillator which have been newly developed by our group at the Heavy-Ion Medical Accelerator in Chiba (HIMAC) of National Institute of Radiological Sciences (NIRS), Japan. Neutrons were generated by bombarding 400 MeV/nucleon C ion on a thick (stopping-length) copper target. The neutron spectra in the energy range from 20 to 800 MeV were obtained through the FORIST unfolding code with their response functions and compared with the MCNPX calculations combined with the LA150 cross section library. The neutron fluence measured by the NE213 detector was simulated by the track length estimator in the MCNPX, and evaluated the contribution of the room-scattered neutrons. The calculations are in fairly good agreement with the measurements. Neutron fluence attenuation lengths were obtained from the experimental results and the calculation.

  6. Monte Carlo simulation of prompt gamma-ray spectra from depleted uranium under D-T neutron irradiation and electron recoil spectra in a liquid scintillator detector

    CERN Document Server

    Qin, Jianguo; Liu, Rong; Zhu, Tonghua; Zhang, Xinwei; Ye, Bangjiao

    2015-01-01

    To overcome the problem of inefficient computing time and unreliable results in MCNP5 calculation, a two-step method is adopted to calculate the energy deposition of prompt gamma-rays in detectors for depleted uranium spherical shells under D-T neutrons irradiation. In the first step, the gamma-ray spectrum for energy below 7 MeV is calculated by MCNP5 code; secondly, the electron recoil spectrum in a BC501A liquid scintillator detector is simulated based on EGSnrc Monte Carlo Code with the gamma-ray spectrum from the first step as input. The comparison of calculated results with experimental ones shows that the simulations agree well with experiment in the energy region 0.4-3 MeV for the prompt gamma-ray spectrum and below 4 MeVee for the electron recoil spectrum. The reliability of the two-step method in this work is validated.

  7. Liquid scintillation counting standardization of 125I in organic and inorganic samples by the CIEMAT/NIST method; Calibracion por centelleo liquido del 125I en muestras inorganicas y organicas, mediante el metodo CIEMAT/NIST

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Barquero, L.; Grau Malonda, A.; Los Arcos Merino, J. M.; Grau Carles, A.

    1994-07-01

    The liquid scintillation counting standardization of organic and inorganic samples of ''I25I by the CIEMAT/NIST method using five different scintillators is described. The discrepancies between experimental and computed efficiencies are lower than 1.4% and 1.7%, for inorganic and organic samples, respectively, in the interval 421-226 of quenching parameter. Both organic and inorganic solutions have been standardized in terms of activity concentration to an overall uncertainty of 0.76%. (Author) 14 refs.

  8. Measurement of the scintillation time spectra and pulse-shape discrimination of low-energy beta and nuclear recoils in liquid argon with DEAP-1

    CERN Document Server

    Boulay, M G; Chen, M; Golovko, V V; Harvey, P; Mathew, R; Lidgard, J J; McDonald, A B; Pasuthip, P; Pollman, T; Skensved, P; Graham, K; Hallin, A L; McKinsey, D N; Lippincott, W H; Nikkel, J; Jillings, C J; Duncan, F; Cleveland, B; Lawson, I

    2009-01-01

    The DEAP-1 low-background liquid argon detector has been used to measure scintillation pulse shapes of beta decays and nuclear recoil events and to demonstrate the feasibility of pulse-shape discrimination down to an electron-equivalent energy of 20 keVee. The relative intensities of singlet/triplet states in liquid argon have been measured as a function of energy between 15 and 500 keVee for both beta and nuclear recoils. Using a triple-coincidence tag we find the fraction of beta events that are mis-identified as nuclear recoils to be less than 6x10^{-8} between 43-86 keVee and that the discrimination parameter agrees with a simple analytic model. The discrimination measurement is currently limited by nuclear recoils induced by cosmic-ray generated neutrons, and is expected to improve by operating the detector underground at SNOLAB. The analytic model predicts a beta mis-identification fraction of 10^{-10} for an electron-equivalent energy threshold of 20 keVee. This reduction allows for a sensitive search ...

  9. Detection of gamma-rays with a 3.5 l liquid xenon ionization chamber triggered by the primary scintillation light

    CERN Document Server

    Aprile, E; Chen Dan Li; Muhkerjee, R; Xu Fan

    2002-01-01

    A gridded ionization chamber with a drift length of 4.5 cm and a total volume of 3.5 l, was operated with high-purity liquid xenon and extensively tested with gamma-rays from sup 1 sup 3 sup 7 Cs, sup 2 sup 2 Na and sup 6 sup 0 Co radioactive sources. An electron lifetime in excess of 1 ms was inferred from two independent measurements. The electric field dependence of the collected charge and energy resolution was studied in the range 0.1-4 kV/cm, for different gamma-ray energies. With an electric field of 4 kV/cm, the spectral performance of the detector is consistent with an energy resolution of 5.9% at 1 MeV, scaling with energy as E sup - sup 0 sup . sup 5. The chamber was also used to detect the primary scintillation light produced by gamma-ray interactions in liquid xenon. The light signal was successfully used to trigger the acquisition of the charge signal with a FADC readout. A trigger efficiency of approx 85% was measured at 662 keV.

  10. Neutron/gamma discrimination properties of composite scintillation detectors

    Energy Technology Data Exchange (ETDEWEB)

    Iwanowska, J; Swiderski, L; Moszynski, M; Szczesniak, T; Sibczynski, P [The Soltan Institute for Nuclear Studies, Otwock-Swierk, PL-05-400 Poland (Poland); Galunov, N Z; Karavaeva, N L, E-mail: j.iwanowska@ipj.gov.pl [The Institute for Scintillation Materials of National Academy of Sciences of Ukraine, 60 Lenin Ave., 61001, Kharkov (Ukraine)

    2011-07-15

    A composite scintillator is a solid solution, which contains the grains of organic molecular single crystal introduced into a polymer matrix and placed inside the housing. Hereunder, we present n/{gamma} discrimination properties of four composite scintillators; two of the them are based on p-terphenyl and two others-on stilbene. The results obtained with a stilbene single crystal and a liquid scintillator BC501A are shown as a comparison. Initial conclusion, which is drawn from the paper, is that composite scintillators could be an alternative substitution for commonly used liquid scintillators.

  11. Linear lateral vibration of axisymmetric liquid briges

    Science.gov (United States)

    Ferrera, C.; Montanero, J. M.; Cabezas, M. G.

    A liquid bridge is a mass of liquid sustained by the action of the surface tension force between two parallel supporting disks Apart from their basic scientific interest a liquid bridge can be considered as the simplest idealization of the configuration appearing in the floating zone technique used for crystal growth and purification of high melting point materials footnote Messeguer et al emph Crystal Growth Res bf 5 27 1999 This has conferred considerable interest on the study of liquid bridges not only in fluid mechanics but also in the field of material engineering The axisymmetric dynamics of an isothermal liquid bridge has been frequently analysed over the past years The studies have considered different phenomena such as free oscillations footnote Montanero emph E J Mech B Fluids bf 22 169 2003 footnote Acero and Montanero emph Phys Fluids bf 17 078105 2005 forced vibrations footnote Perales and Messeguer emph Phys Fluids A bf 4 1110 1992 g-jitter effects footnote Messeguer and Perales emph Phys Fluids A bf 3 2332 1991 extensional deformation footnote Zhang et al emph J Fluid Mech bf 329 207 1996 and breakup process footnote Espino et al emph Phys Fluids bf 14 3710 2002 among others Works considering the nonaxisymmetric dynamical behaviour of a liquid bridge has been far less common footnote Sanz and Diez emph J Fluid Mech bf 205 503 1989 In the present study the linear vibration of an axisymmetric liquid

  12. Preparation of manganese salts of carboxylic acids labelled with ''54Mn and comparison with ''54 MnCl{sub 2} in liquid scintillation counting; Preparacion de sales manganosas de acidos alifaticos monocarboxilicos marcados con ''54 MnCl{sub 2} en medidas por centelleo liquido

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Barquero, L.; Arcos Merino, J. M. los; Grau Malonda, A.

    1992-07-01

    Procedures for liquid scintillation sample preparation of manganese dimethylbutirate, decanoate and palmitate, labelled with 54 Mn are described. their quenching effect, spectral evolution and counting stability along several weeks are analysed in liquid scintillation measurements with Toluene. HISafe II. PCS, instagel. Dioxane-naphtalene and Toluene-alcohol. For comparison, Inorganic 54 MnCl-2 samples are also studied, resulting in acceptable counting stability but showing greater quenching and signs of little spectral degradation against the organic samples. (Author)

  13. Influence of atomic and nuclear constants on the counting efficiency for 55{sup F}e in liquid scintillators; Influencia de los parametros atomicos y nucleares en la calibracion de 55{sup F}e mediante centelleo liquido

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez, A.; Grau, A.; Arcos, J. M. los

    1985-07-01

    In this paper one considers the influence of the different parameters on the determination of the uncertainty of the detection efficiency for 55{sup F}e when the counting technique of liquid scintillation is applied. The following parameters are considered: the relative probabilities of X and Auger emission so as their corresponding energies, the fluorescence yields W{sup K} and W{sup L}, and the non-interaction probabilities of the emitted X photons. (Author) 11 refs.

  14. Determination of Carbon-14 in environmental samples by mixing 14CO{sub 2} with a liquid scintillator; Determinacion de carbono-14 en muestras ambientales por incorporacion de 14CO{sub 2} a un centelleador liquido

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, M. R.; Gomez, V.; Heras, M. C.; Beltran, M. A.

    1990-07-01

    A method for the determination of Carbon-14 (14CO2) in environmental samples has been developed. The method use the direct absorption of the carbon dioxide into Carbosorb, followed with incorporation of the mixture (Carbosorb-CO2) to the liquid scintillator. The results obtained to apply this method and the benzene synthesis, usual in our laboratory, are discussed and compared. The method of collection of atmospheric samples is also described. (Author) 10 refs.

  15. Liquid Scintillation Counting Standardization of {sup 2}2NaCl by te CIEMAT/NIST method; Calibracion por Centelleo Liquido del ''22NaCl, mediante el metodo CIEMAT/NIST

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Barquero, L.; Grau Carles, A.; Grau Malonda, A.

    1995-07-01

    We describe a procedure for preparing a stable solution of ''22NaCl for liquid scintillation counting and its counting stability and spectral evolution in Insta-Gel''R is studied. The solution has been standardised in terms of activity concentration by the CIEMAT/NIST method with discrepancies between experimental and computed efficiencies lower than 0.4 % and an overall uncertainty of 0.35 %. (Author) 4 refs.

  16. Measurement by liquid scintillation of {sup 226} Ra coprecipitated in BaSO{sub 4}; Medicion por centelleo liquido de {sup 226} Ra coprecipitado en BaSO{sub 4}

    Energy Technology Data Exchange (ETDEWEB)

    Lopez del Rio, H.; Davila R, J.I.; Badillo A, V.E.; Mireles G, F.; Quirino T, L.; Lugo R, J.F.; Pinedo V, J.L.; Rios M, C. [UAEN-UAZ, A.P. 579C, Cipres 10, Fracc. La Penuela, 98068 Zacatecas (Mexico)]. e-mail: idavila@cantera.reduaz.mx

    2003-07-01

    The {sup 226} Ra is one of the more radio toxic nuclides since when entering to the organism it continues metabolically to the calcium, accumulating mainly in the bone tissue where it becomes in an internal radiation source. For the analysis of radium in water the methods of radon emanation are generally applied and coprecipitation with barium sulfate. This last is quick and efficient, and the radium in the precipitate can be measured by alpha or gamma spectrometry, or liquid scintillation dissolving the precipitate one with EDTA. In this work it is proposed a procedure for the radium measurement in water based on the coprecipitation with barium sulfate and in the detection by liquid scintillation. The precipitate of Ba(Ra)SO{sub 4} it is carried with water and blended with the liquid scintillator OptiPhase Hi Safe 3, avoiding the dissolution with EDTA. A 92{+-} 1.4% of radium it was recovered and it was reached a minimum activity detectable of 4.2 {+-} 0.9 mBq{sup -1}. The procedure was essayed with natural mineral water with a knew activity in concentration of {sup 226} Ra. The analytic result it coincided with the reported value with a relative error of 9%. (Author)

  17. Effective determination of the long-lived nuclide 41Ca in nuclear reactor bioshield concretes: comparison of liquid scintillation counting and accelerator mass spectrometry.

    Science.gov (United States)

    Warwick, P E; Croudace, I W; Hillegonds, D J

    2009-03-01

    The routine application of liquid scintillation counting to (41)Ca determination has been hindered by the absence of traceable calibration standards of known (41)Ca activity concentrations. The introduction of the new IRMM (41)Ca mass-spectrometric standards with sufficiently high (41)Ca activities for radiometric detection has partly overcome this although accurate measurement of stable Ca concentrations coupled with precise half-life data are still required to correct the certified (41)Ca:(40)Ca ratios to (41)Ca activity concentrations. In this study, (41)Ca efficiency versus quench curves have been produced using the IRMM standard, and their accuracy validated by comparison with theoretical calculations of (41)Ca efficiencies. Further verification of the technique was achieved through the analysis of (41)Ca in a reactor bioshield core that had been previously investigated for other radionuclide variations. Calcium-41 activity concentrations of up to 25 Bq/g were detected. Accelerator mass spectrometry (AMS) measurements of the same suite of samples showed a very good agreement, providing validation of the procedure. Calcium-41 activity concentrations declined exponentially with distance from the core of the nuclear reactor and correlated well with the predicted neutron flux.

  18. Determination of {sup 55}Fe in waste waters of the Krsko nuclear power plant measured simultaneously by liquid scintillation spectrometer (LSC) and X-ray spectrometer (XRS)

    Energy Technology Data Exchange (ETDEWEB)

    Mikelic, L. [Rudjer Boskovic Institute, Laboratory for Radioecology, Bijenicka Cesta 54, 10000 Zagreb (Croatia)], E-mail: lmikelic@irb.hr; Orescanin, V.; Lulic, S. [Rudjer Boskovic Institute, Laboratory for Radioecology, Bijenicka Cesta 54, 10000 Zagreb (Croatia)

    2007-10-15

    This paper presents comparison of two methods for the determination of {sup 55}Fe activity of waste waters discharged from the Krsko nuclear power plant (KNPP). Research was conducted on 12 composite samples of waste water collected in the waste monitor tank (WMT) during each month as well as on Analytics, Inc. cross-check sample. Results showed that the complicated and time-consuming method proposed by the Environmental Measurements Laboratory (EML) could be successfully replaced with a simple and fast based on the extraction of {sup 55}Fe from waste water by non-specific chelating agent ammonium-pyrrolidinedithiocarbamate (APDC) at pH 4 after separation from cobalt, and activity measurement by X-ray fluorescence spectroscopy (XRS). Results obtained by the XRS method were approximately 8.6% lower than those obtained by liquid scintillation spectrometer (LSC). The mean deviation of the XRS results from the activity of cross-check sample was 2.47%, which ensures that this method is accurate enough for environmental monitoring.

  19. Determination of 55Fe in waste waters of the Krsko nuclear power plant measured simultaneously by liquid scintillation spectrometer (LSC) and X-ray spectrometer (XRS)

    Science.gov (United States)

    Mikelic, L.; Orescanin, V.; Lulic, S.

    2007-10-01

    This paper presents comparison of two methods for the determination of 55Fe activity of waste waters discharged from the Krsko nuclear power plant (KNPP). Research was conducted on 12 composite samples of waste water collected in the waste monitor tank (WMT) during each month as well as on Analytics, Inc. cross-check sample. Results showed that the complicated and time-consuming method proposed by the Environmental Measurements Laboratory (EML) could be successfully replaced with a simple and fast based on the extraction of 55Fe from waste water by non-specific chelating agent ammonium-pyrrolidinedithiocarbamate (APDC) at pH 4 after separation from cobalt, and activity measurement by X-ray fluorescence spectroscopy (XRS). Results obtained by the XRS method were approximately 8.6% lower than those obtained by liquid scintillation spectrometer (LSC). The mean deviation of the XRS results from the activity of cross-check sample was 2.47%, which ensures that this method is accurate enough for environmental monitoring.

  20. Development of liquid scintillation based 4πβ(LS)-γ coincidence counting system and demonstration of its performance by standardization of ⁶⁰Co.

    Science.gov (United States)

    Kulkarni, D B; Anuradha, R; Joseph, Leena; Tomar, B S

    2013-02-01

    A single-vial, single-PMT 4πβ(LS)-γ coincidence counting system has been developed at the Radiation Safety Systems Division, BARC. It has advantages of simple sample preparation, higher counting efficiency and the absence of self absorption over the conventional proportional counter based 4πβ(PC)-γ coincidence counting system. The performance of the system is demonstrated by standardizing a (60)Co solution using the 4πβ(LS)-γ coincidence counting system, 4πβ(PC)-γ coincidence counting system and CIEMAT/NIST method and comparing the results obtained by each method. The detection efficiency of liquid scintillation counter of the 4πβ(LS)-γ coincidence counting system was varied by color quenching, by chemical quenching and by varying the bias voltage applied to the LSC PMT. For the proportional counter based 4πβ(PC)-γ coincidence counting system the detection efficiency was varied by source self absorption. The activity concentrations obtained using the 4πβ(LS)-γ coincidence counting system, the 4πβ(PC)-γ coincidence counting system and the CIEMAT/NIST method are comparable within the uncertainty limits.

  1. Measurement of radon in air using the PICO-RAD detector and a liquid scintillation spectrometer. 2. Misasa district, Tottori pref. on sampling of 1993

    Energy Technology Data Exchange (ETDEWEB)

    Koga, Taeko; Inagaki, Masayo; Morishima, Hiroshige; Kawai, Hiroshi; Kondo, Sohei [Kinki Univ., Higashi-Osaka, Osaka (Japan). Atomic Energy Research Inst.; Morishita, Satoru; Kitamura, Naoya; Mifune, Masaaki

    1994-12-01

    A convenient radon detecting device for the purpose of estimating natural radiation exposure is described. The {alpha} radioactivity of its daughters originated from radon gas adsorbed in fine active carbon particles exposed to air is measured with a liquid scintillation spectrometer (Packard PICO-RAD system). Its detection limit is 1.7 Bq/m{sup 3} in air with an accuracy of about 10% on 200 minutes of counting time, and correction coefficient, the ratio of measured radon concentration to standard radon concentration (about 300 Bq/m{sup 3}) is 0.75 on the standard radon gas chamber of Power Reactor and Nuclear Fuel Development Corporation. Radon concentrations at Misasa hot springs in Tottori prefecture were measured using the PICO-RAD method on 1993. They were 128-3,600 Bq/m{sup 3} in a bath room, 25-45 Bq/m{sup 3} outdoors and 28-89 Bq/m{sup 3} indoors. (author).

  2. Development and Mass Production of a Mixture of LAB- and DIN-based Gadolinium-loaded Liquid Scintillator for the NEOS Short-baseline Neutrino Experiment

    CERN Document Server

    Kim, Ba Ro; Jeon, Eun-ju; Joo, Kyung Kwang; Kim, H J; Kim, Hyunsoo; Kim, Jinyu; Kim, Yeongduk; Ko, Youngju; Lee, Jaison; Lee, Jooyoung; Lee, Moohyun; Ma, Kyungju; Oh, Yoomin; Park, Hyangkyu; Park, Kang-soon; Seo, Kyungmin; Seon, Gwang-Min; Siyeon, Kim

    2015-01-01

    A new experiment, which is called as NEOS (NEutrino Oscillation at Short baseline), is proposed on the site of Hanbit reactors at Yonggwang, South Korea, to investigate a reactor antineutrino anomaly. A homogeneous NEOS detector having a 1000-L target volume has been constructed and deployed at the tendon gallery ~25 m away from the reactor core. A linear alkylbenzene (LAB) is used as a main base solvent of the NEOS detector. Furthermore, a di-isopropylnaphthalene (DIN) is added to improve the light output and pulse shape discrimination (PSD) ability. The ratio of LAB to DIN is 90:10. PPO (3 g/L) and bis-MSB (30 mg/L) are dissolved to formulate the mixture of LAB- and DIN-based liquid scintillator (LS). Then, ~0.5% gadolinium (Gd) is loaded into the LS by using the solvent-solvent extraction technique. In this paper, we report the characteristics of Gd-loaded LS (GdLS) for the NEOS detector and the handling during mass production.

  3. Survey on the presence of 90Sr in milk samples by a validated ultra low level liquid scintillation counting (LSC method

    Directory of Open Access Journals (Sweden)

    dell’Oro D.

    2013-04-01

    Full Text Available 90Sr is one of the most biologically hazardous radionuclides produced in nuclear fission processes and decays emitting high-energy beta particles turning 90Y. 90Sr is transferred from soil-plant to cow’s milk and then to humans if it is introduced into the environment. Radiostrontium is chemically similar to calcium entering the human body through several food chains and depositing in bone and blood-forming tissue (bone marrow. Among main foodstuffs assumed in human diet, milk is considered of special interest for radiostrontium determination, especially in emergency situations, because the consumption of contaminated milk is the main source of internal radiation exposure, particularly for infants. In this work an analytical method for the determination of radiostrontium in milk was developed and validated in order to determine low activity levels by liquid scintillation counting (LSC after achieving 90Y secular equilibrium condition. The analytical procedure was applied both in surveillance and routine programmes to detect radiocontamination in cow’s, goat and sheep milk samples.

  4. Systematic study of particle quenching in organic scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Santiago, L.M.; Bagán, H. [Department of Analytical Chemistry of the University of Barcelona, Diagonal 645, E-08028 Barcelona (Spain); Tarancón, A., E-mail: alex.tarancon@ub.edu [Department of Analytical Chemistry of the University of Barcelona, Diagonal 645, E-08028 Barcelona (Spain); Rauret, G.; Garcia, J.F. [Department of Analytical Chemistry of the University of Barcelona, Diagonal 645, E-08028 Barcelona (Spain)

    2013-01-11

    Among the different factors that affect measurements by organic scintillators, the majority of attention has been focused on those related to the scintillator (i.e., ionization, chemical, color and optical quenching), and less attention has been paid to the loss of energy before the particle (i.e., alpha or beta) arrives at the scintillator (i.e., particle quenching). This study evaluates the effect of particle quenching in different scintillation methods (i.e., using two plastic scintillation microspheres (PSm1 and PSm2), liquid scintillator and gel scintillator) by measuring solutions that contain increasing concentrations of NaCl, BaCl{sub 2} and glycerin. The results show the importance of particle quenching in PSm measurements because detection efficiency decreases with increasing concentrations of the quenching component, although the spectrum position and external standard parameter remain constant. The results have shown evidence of particle quenching, although at a lower magnitude, in the liquid scintillation or gel scintillation measurements. Moreover, the use of two PSm with different diameters and salty compound that alters the equilibrium of the liquid and gel emulsions also exemplified the importance of the transmission of optical photons through different scintillation media (i.e., optical quenching). Improvement and deterioration of the optical conditions on the scintillation media is manifested as a movement of the spectrum to higher and lower energies, respectively. The results obtained with PSm were confirmed by Monte Carlo simulation.

  5. 直径30cm的等高圆柱形载钆液闪探测性能%Performance measurement of large volume ?30 cm×30 cm gadolinium-loaded liquid scintillator detector

    Institute of Scientific and Technical Information of China (English)

    朱传新; 牟云峰; 郑普

    2016-01-01

    Background: The gadolinium-loaded liquid scintillator detector is an important tool for particle detecting in the area of high energy physics and nuclear physics experiments.Purpose: In this work, a large-size?30cm×30cm gadolinium-loaded liquid scintillator detector has been developed for neutron measurement. Neutron gamma discrimination and distribution of neutron capture time of gadolinium-loaded liquid scintillator were main values of detecting performance.Methods: The n-gamma discrimination of the large-size gadolinium-loaded liquid scintillator detector has been studied using a252Cf spontaneous fission neutron source by zero-crossing method. It was observed that the neutron-gamma discrimination property of large-size gadolinium-loaded liquid scintillator detector was poor. n-gamma discrimination spectra of?30 cm×30 cm gadolinium-loaded liquid scintillator detector within1μs after the fission event were captured with coincidence method based on the start signal of fission fragment from252Cf fission chamber.Results: It was observed that the neutron-gamma discrimination property of large-size gadolinium-loaded liquid scintillator detector was also poor. The time distributions of neutron and gamma in the n-gamma discrimination spectra were measured by time-of-flight (TOF) technique and coincidence method. The peak time difference of neutron time distribution and gamma time distribution was 2 ns. The distribution of neutron capture time was measured for a?30 cm×30 cm gadolinium-loaded liquid scintillator detector with coincidence method based on the start signal of fission fragment from252Cf fission chamber. The main signals ofγ by neutron capture of?30 cm×30 cm gadolinium-loaded liquid scintillator detector were in about 30μs. The average time of neutron capture is 11μs. Conclusion: The neutron capture time property of homemade gadolinium-loaded liquid scintillator meets the experimental requirements. For the most signal of neutron and gamma within the

  6. Metal-loaded organic scintillators for neutrino physics

    CERN Document Server

    Buck, Christian

    2016-01-01

    Organic liquid scintillators are used in many neutrino physics experiments of the past and present. In particular for low energy neutrinos when realtime and energy information are required, liquid scintillators have several advantages compared to other technologies. In many cases the organic liquid needs to be loaded with metal to enhance the neutrino signal over background events. Several metal loaded scintillators of the past suffered from chemical and optical instabilities, limiting the performance of these neutrino detectors. Different ways of metal loading are described in the article with a focus on recent techniques providing metal loaded scintillators that can be used under stable conditions for many years even in ton scale experiments. Applications of metal loaded scintillators in neutrino experiments are reviewed and the performance as well as the prospects of different scintillator types are compared.

  7. Metal-loaded organic scintillators for neutrino physics

    Science.gov (United States)

    Buck, Christian; Yeh, Minfang

    2016-09-01

    Organic liquid scintillators are used in many neutrino physics experiments of the past and present. In particular for low energy neutrinos when realtime and energy information are required, liquid scintillators have several advantages compared to other technologies. In many cases the organic liquid needs to be loaded with metal to enhance the neutrino signal over background events. Several metal loaded scintillators of the past suffered from chemical and optical instabilities, limiting the performance of these neutrino detectors. Different ways of metal loading are described in the article with a focus on recent techniques providing metal loaded scintillators that can be used under stable conditions for many years even in ton scale experiments. Applications of metal loaded scintillators in neutrino experiments are reviewed and the performance as well as the prospects of different scintillator types are compared.

  8. A comparative study of 19-iodo cholesterol-125I 3-acetate and Na 125I in liquid scintillation measurements; Estudio comparativo del acetato de 19-iodocolesterol- -125I con Nal25I en medidas por centelleo liquido

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Barquero, L.; Grau Malonda, A.; Los Arcos Merino, J. M.; Grau Carles, A.

    1994-07-01

    A comparative study of performance of 19-iodo cholesterol {sup 1}25I 3-acetate and sodium iodide samples labeled with 125I is presented for liquid scintillation counting measurements. Quench effect, count rate stability and spectral evolution of samples have been followed for several weeks in Toluene, Hisafe II, Instagel, Dioxane-naphthalene and Toluene-alcohol scintillators. Organic samples have negligible quench effect in the interval of I concentration of 0-90 {mu}g and inorganic samples only show a very small variation, lower than 12%, for Dioxane-naphthalene, in the same range of concentration. Satisfactory stability is obtained in general for both, organic and inorganic samples, but small counting losses, 0.03% for 19-iodocholesterol 1 I 3-acetate samples in Tolue ne-alcohol and 0 .04% for Na 125I samples in Dioxane-naphthalene and Toluene-alcohol, have been reported. (Author) 8 refs.

  9. A new value for the half-life of {sup 10}Be by Heavy-Ion Elastic Recoil Detection and liquid scintillation counting

    Energy Technology Data Exchange (ETDEWEB)

    Korschinek, G., E-mail: Gunther.Korschinek@ph.tum.d [Physik Department, Technische Universitaet Muenchen, D-85748 Garching (Germany); Bergmaier, A. [Universitaet der Bundeswehr Muenchen, Fakultaet fuer Luft- und Raumfahrttechnik, Institut fuer Angewandte Physik und Messtechnik LRT2, Werner-Heisenberg-Weg 39, D-85577 Neubiberg (Germany); Faestermann, T. [Physik Department, Technische Universitaet Muenchen, D-85748 Garching (Germany); Gerstmann, U.C. [Helmholtz Zentrum Muenchen, German Research Center for Environmental Health, Institute of Radiation Protection, Ingolstaedter Landstr. 1, D-85764 Neuherberg (Germany); Knie, K.; Rugel, G. [Physik Department, Technische Universitaet Muenchen, D-85748 Garching (Germany); Wallner, A. [VERA Laboratory, Faculty of Physics, University of Vienna, Waehringer Strasse 17, A-1090 Wien (Austria); Dillmann, I. [Physik Department, Technische Universitaet Muenchen, D-85748 Garching (Germany); Dollinger, G. [Universitaet der Bundeswehr Muenchen, Fakultaet fuer Luft- und Raumfahrttechnik, Institut fuer Angewandte Physik und Messtechnik LRT2, Werner-Heisenberg-Weg 39, D-85577 Neubiberg (Germany); Lierse von Gostomski, Ch. [Lehrstuhl fuer Radiochemie, Technische Universitaet Muenchen, D-85748 Garching (Germany); Kossert, K. [Physikalisch-Technische Bundesanstalt, Braunschweig (Germany); Maiti, M.; Poutivtsev, M. [Physik Department, Technische Universitaet Muenchen, D-85748 Garching (Germany); Remmert, A. [Lehrstuhl fuer Radiochemie, Technische Universitaet Muenchen, D-85748 Garching (Germany)

    2010-01-15

    The importance of {sup 10}Be in different applications of accelerator mass spectrometry (AMS) is well-known. In this context the half-life of {sup 10}Be has a crucial impact, and an accurate and precise determination of the half-life is a prerequisite for many of the applications of {sup 10}Be in cosmic-ray and earth science research. Recently, the value of the {sup 10}Be half-life has been the centre of much debate. In order to overcome uncertainties inherent in previous determinations, we introduced a new method of high accuracy and precision. An aliquot of our highly enriched {sup 10}Be master solution was serially diluted with increasing well-known masses of {sup 9}Be. We then determined the initial {sup 10}Be concentration by least square fit to the series of measurements of the resultant {sup 10}Be/{sup 9}Be ratio. In order to minimize uncertainties because of mass bias which plague other low-energy mass spectrometric methods, we used for the first time Heavy-Ion Elastic Recoil Detection (HI-ERD) for the determination of the {sup 10}Be/{sup 9}Be isotopic ratios, a technique which does not suffer from difficult to control mass fractionation. The specific activity of the master solution was measured by means of accurate liquid scintillation counting (LSC). The resultant combination of the {sup 10}Be concentration and activity yields a {sup 10}Be half-life of T{sub 1/2} = 1.388 +- 0.018 (1 s, 1.30%) Ma. In a parallel but independent study (Chmeleff et al. ), found a value of 1.386 +- 0.016 (1.15%) Ma. Our recommended weighted mean and mean standard error for the new value for {sup 10}Be half-life based on these two independent measurements is 1.387 +- 0.012 (0.87%) Ma.

  10. Broad Energy Range Neutron Spectroscopy using a Liquid Scintillator and a Proportional Counter: Application to a Neutron Spectrum Similar to that from an Improvised Nuclear Device.

    Science.gov (United States)

    Xu, Yanping; Randers-Pehrson, Gerhard; Marino, Stephen A; Garty, Guy; Harken, Andrew; Brenner, David J

    2015-09-11

    A novel neutron irradiation facility at the Radiological Research Accelerator Facility (RARAF) has been developed to mimic the neutron radiation from an Improvised Nuclear Device (IND) at relevant distances (e.g. 1.5 km) from the epicenter. The neutron spectrum of this IND-like neutron irradiator was designed according to estimations of the Hiroshima neutron spectrum at 1.5 km. It is significantly different from a standard reactor fission spectrum, because the spectrum changes as the neutrons are transported through air, and it is dominated by neutron energies from 100 keV up to 9 MeV. To verify such wide energy range neutron spectrum, detailed here is the development of a combined spectroscopy system. Both a liquid scintillator detector and a gas proportional counter were used for the recoil spectra measurements, with the individual response functions estimated from a series of Monte Carlo simulations. These normalized individual response functions were formed into a single response matrix for the unfolding process. Several accelerator-based quasi-monoenergetic neutron source spectra were measured and unfolded to test this spectroscopy system. These reference neutrons were produced from two reactions: T(p,n)(3)He and D(d,n)(3)He, generating neutron energies in the range between 0.2 and 8 MeV. The unfolded quasi-monoenergetic neutron spectra indicated that the detection system can provide good neutron spectroscopy results in this energy range. A broad-energy neutron spectrum from the (9)Be(d,n) reaction using a 5 MeV deuteron beam, measured at 60 degrees to the incident beam was measured and unfolded with the evaluated response matrix. The unfolded broad neutron spectrum is comparable with published time-of-flight results. Finally, the pair of detectors were used to measure the neutron spectrum generated at the RARAF IND-like neutron facility and a comparison is made to the neutron spectrum of Hiroshima.

  11. Scintillation particle detection based on microfluidics

    CERN Document Server

    Mapelli, A; Renaud, P; Gorini, B; Trivino, N Vico; Jiguet, S; Vandelli, W; Haguenauer, M

    2010-01-01

    A novel type of particle detector based on scintillation, with precise spatial resolution and high radiation hardness, is being studied. It consists of a single microfluidic channel filled with a liquid scintillator and is designed to define an array of scintillating waveguides each independently coupled to a photodetector. Prototype detectors built using an SU-8 epoxy resin have been tested with electrons from a radioactive source. The experimental results show a light yield compatible with the theoretical expectations and confirm the validity of the approach. (C) 2010 Elsevier B.V. All rights reserved.

  12. Energy resolution of scintillation detectors

    Energy Technology Data Exchange (ETDEWEB)

    Moszyński, M., E-mail: M.Moszynski@ncbj.gov.pl; Syntfeld-Każuch, A.; Swiderski, L.; Grodzicka, M.; Iwanowska, J.; Sibczyński, P.; Szczęśniak, T.

    2016-01-01

    According to current knowledge, the non-proportionality of the light yield of scintillators appears to be a fundamental limitation of energy resolution. A good energy resolution is of great importance for most applications of scintillation detectors. Thus, its limitations are discussed below; which arise from the non-proportional response of scintillators to gamma rays and electrons, being of crucial importance to the intrinsic energy resolution of crystals. The important influence of Landau fluctuations and the scattering of secondary electrons (δ-rays) on intrinsic resolution is pointed out here. The study on undoped NaI and CsI at liquid nitrogen temperature with a light readout by avalanche photodiodes strongly suggests that the non-proportionality of many crystals is not their intrinsic property and may be improved by selective co-doping. Finally, several observations that have been collected in the last 15 years on the influence of the slow components of light pulses on energy resolution suggest that more complex processes are taking place in the scintillators. This was observed with CsI(Tl), CsI(Na), ZnSe(Te), and undoped NaI at liquid nitrogen temperature and, finally, for NaI(Tl) at temperatures reduced below 0 °C. A common conclusion of these observations is that the highest energy resolution, and particularly intrinsic resolution measured with the scintillators, characterized by two or more components of the light pulse decay, is obtainable when the spectrometry equipment integrates the whole light of the components. In contrast, the slow components observed in many other crystals degrade the intrinsic resolution. In the limiting case, afterglow could also be considered as a very slow component that spoils the energy resolution. The aim of this work is to summarize all of the above observations by looking for their origin.

  13. Separation of Scintillation and Cherenkov Lights in Linear Alkyl Benzene

    CERN Document Server

    Li, Mohan; Yeh, Minfang; Wang, Zhe; Chen, Shaomin

    2015-01-01

    To separate scintillation and Cherenkov lights in water-based liquid scintillator detectors is a desired feature for future neutrino and proton decay researches. Linear alkyl benzene (LAB) is one important ingredient of a water-based liquid scintillator being developed. In this paper we observed a good separation of scintillation and Cherenkov lights in an LAB sample. The rising and decay times of the scintillation light of the LAB were measured to be $(7.7\\pm3.0)\\ \\rm{ns}$ and $(36.6\\pm2.4)\\ \\rm{ns}$, respectively, while the full width [-3$\\sigma$, 3$\\sigma$] of the Cherenkov light was 12 ns dominated by the time resolution of our photomultiplier tubes. The light yield of the scintillation was measured to be $(1.01\\pm0.12)\\times10^3\\ \\rm{photons}/\\rm{MeV}$.

  14. Evaluation of the uncertainty for the efficiency curve determination of {sup 210}Pb by liquid scintillation; Avaliacao da incerteza para a curva de eficiencia da determinacao de {sup 210}Pb por cintilacao liquida

    Energy Technology Data Exchange (ETDEWEB)

    Sampaio, C.S.; Sousa, W.O.; Dantas, B.M., E-mail: camilla@ird.gov.br [Instituto de Radioprotecao e Dosimetria, (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2014-07-01

    Methodologies for the evaluation of uncertainties associated with the determination of the efficiency curve of {sup 210}Pb by liquid scintillation counting (LSC) are presented. No statistical difference were found when compared the uncertainties of the curves that represented the counting net before and after the secular equilibrium between {sup 210}Pb and {sup 210}Bi, nether when compared the curves when counting only {sup 210}Pb and the curve with the total count of {sup 210}Pb and {sup 210}Bi, for the same time interval after precipitation. (author)

  15. Scintillator materials for calorimetry

    Energy Technology Data Exchange (ETDEWEB)

    Weber, M.J. [Lawrence Berkeley Lab., CA (United States). Life Sciences Div.

    1994-09-01

    Requirements for fast, dense scintillator materials for calorimetry in high energy physics and approaches to satisfying these requirements are reviewed with respect to possible hosts and luminescent species. Special attention is given to cerium-activated crystals, core-valence luminescence, and glass scintillators. The present state of the art, limitations, and suggestions for possible new scintillator materials are presented.

  16. Scintillation response of organic and inorganic scintillators

    CERN Document Server

    Papadopoulos, L M

    1999-01-01

    A method to evaluate the scintillation response of organic and inorganic scintillators to different heavy ionizing particles is suggested. A function describing the rate of the energy consumed as fluorescence emission is derived, i.e., the differential response with respect to time. This function is then integrated for each ion and scintillator (anthracene, stilbene and CsI(Tl)) to determine scintillation response. The resulting scintillation responses are compared to the previously reported measured responses. Agreement to within 2.5% is observed when these data are normalized to each other. In addition, conclusions regarding the quenching parameter kB dependence on the type of the particle and the computed values of kB for certain ions are included. (author)

  17. Characterization of the scintillation anisotropy in crystalline stilbene scintillator detectors

    CERN Document Server

    Schuster, Patricia

    2016-01-01

    This paper reports a series of measurements that characterize the directional dependence of the scintillation response of crystalline melt-grown and solution-grown stilbene to incident DT and DD neutrons. These measurements give the amplitude and pulse shape dependence on the proton recoil direction over one hemisphere of the crystal, confirming and extending previous results in the literature for melt-grown stilbene and providing the first measurements for solution-grown stilbene. In similar measurements of liquid and plastic detectors, no directional dependence was observed, confirming the hypothesis that the anisotropy in stilbene and other organic crystal scintillators is a result of internal effects due to the molecular or crystal structure and not an external effect on the measurement system.

  18. Development of a quasi-monoenergetic neutron field and measurements of the response function of an organic liquid scintillator for the neutron energy range from 66 to 206 MeV

    CERN Document Server

    Nakao, N; Nakamura, T; Uwamino, Y

    2002-01-01

    A quasi-monoenergetic neutron field was developed using a thin sup 7 Li target bombarded by protons in the energy range from 70 to 210 MeV at the RIKEN ring cyclotron facility. The neutron energy spectra were measured with an NE213 organic liquid scintillator using the TOF method. The absolute peak neutron yields were obtained by measurements of 478 keV gamma-rays from sup 7 Be nuclei produced in a sup 7 Li target through the sup 7 Li( p,n) sup 7 Be (g.s.+0.429 MeV) reaction. Using the neutron field, the absolute values of the neutron response functions of a 12.7 cm diameter by 12.7 cm long NE213 organic liquid scintillator were measured, and were compared with calculations using a Monte Carlo code developed by Cecil et al. The measured response functions without any wall-effect events were also obtained, and compared with calculations using a modified Monte Carlo code. Comparisons between a measurement and a calculation both with and without any wall-effect events gave a good agreement.

  19. Subnanosecond Scintillation Detector

    Science.gov (United States)

    Hoenk, Michael (Inventor); Hennessy, John (Inventor); Hitlin, David (Inventor)

    2017-01-01

    A scintillation detector, including a scintillator that emits scintillation; a semiconductor photodetector having a surface area for receiving the scintillation, wherein the surface area has a passivation layer configured to provide a peak quantum efficiency greater than 40% for a first component of the scintillation, and the semiconductor photodetector has built in gain through avalanche multiplication; a coating on the surface area, wherein the coating acts as a bandpass filter that transmits light within a range of wavelengths corresponding to the first component of the scintillation and suppresses transmission of light with wavelengths outside said range of wavelengths; and wherein the surface area, the passivation layer, and the coating are controlled to increase the temporal resolution of the semiconductor photodetector.

  20. Improved Scintillator Materials For Compact Electron Antineutrino Detectors

    NARCIS (Netherlands)

    Dijkstra, Peter; Wortche, Heinrich J.; Browne, Wesley R.

    2012-01-01

    Recent developments provide new components holding the potential to improve the performance of liquid scintillation electron antineutrino detectors used as nuclear reactors monitors. Current systems raise issues regarding size, quantum efficiency, stability, and spatial resolution of the vertex dete

  1. Development and Studies of Novel Microfabricated Radiation Hard Scintillation Detectors With High Spatial Resolution

    CERN Document Server

    Mapelli, A; Haguenauer, M; Jiguet, S; Renaud, P; Vico Triviño, N

    2011-01-01

    A new type of scintillation detector is being developed with standard microfabrication techniques. It consists of a dense array of scintillating waveguides obtained by coupling microfluidic channels filled with a liquid scintillator to photodetectors. Easy manipulation of liquid scintillators inside microfluidic devices allow their flushing, renewal, and exchange making the active medium intrinsically radiation hard. Prototype detectors have been fabricated by photostructuration of a radiation hard epoxy resin (SU-8) deposited on silicon wafers and coupled to a multi-anode photomultiplier tube (MAPMT) to read-out the scintillation light. They have been characterized by exciting the liquid scintillator in the 200 micrometers thick microchannels with electrons from a 90Sr yielding approximately 1 photoelectron per impinging Minimum Ionizing Particle (MIP). These promising results demonstrate the concept of microfluidic scintillating detection and are very encouraging for future developments.

  2. The SNO+ Scintillator Purification Plant and Projected Sensitivity to Solar Neutrinos in the Pure Scintillator Phase

    Science.gov (United States)

    Pershing, Teal; SNO+ Collaboration

    2016-03-01

    The SNO+ detector is a neutrino and neutrinoless double-beta decay experiment utilizing the renovated SNO detector. In the second phase of operation, the SNO+ detector will contain 780 tons of organic liquid scintillator composed of 2 g/L 2,5-diphenyloxazole (PPO) in linear alkylbenzene (LAB). In this phase, SNO+ will strive to detect solar neutrinos in the sub-MeV range, including CNO production neutrinos and pp production neutrinos. To achieve the necessary detector sensitivity, a four-part scintillator purification plant has been constructed in SNOLAB for the removal of ionic and radioactive impurities. We present an overview of the SNO+ scintillator purification plant stages, including distillation, water extraction, gas stripping, and metal scavenger columns. We also give the projected SNO+ sensitivities to various solar-produced neutrinos based on the scintillator plant's projected purification efficiency.

  3. Nonproportionality of inorganic scintillators

    NARCIS (Netherlands)

    Khodyuk, I.V.

    2013-01-01

    A scintillator is a transparent material that emits a flash of light when it absorbs a γ-ray photon or an energetic particle. Scintillation crystals are widely used as spectroscopic detectors of ionizing radiation in nuclear science, space exploration, medical imaging, homeland security, etc. This t

  4. Anticoincidence scintillation counter

    CERN Multimedia

    1966-01-01

    This anticoincidence scintillation counter will be mounted in a hydrogen target vessel to be used in a measurement of the .beta. parameter in the .LAMBDA0. decay. The geometry of the counter optimizes light collection in the central part where a scintillation disk of variable thickness can be fitted.

  5. Improvements in apparatus and procedures for using an organic liquid scintillator as a fast-neutron spectrometer for radiation protection applications

    Energy Technology Data Exchange (ETDEWEB)

    Thorngate, J.H.

    1987-05-15

    For use in radiation protection measurements, a neutron spectrometer must have a wide energy range, good sensitivity, medium resolution, and ease of taking and reducing data. No single spectrometer meets all of these requirements. Several experiments aimed at improving and characterizing the detector response to gamma rays and neutrons were conducted. A light pipe (25 mm) was needed between the scintillator cell and the photomultiplier tube to achieve the best resolution. The light output of the scintillator as a function of gamma-ray energy was measured. Three experiments were conducted to determine the light output as a function of neutron energy. Monte Carlo calculations were made to evaluate the effects of multiple neutron scattering and edge effects in the detector. The electronic systems associated with the detector were improved with a transistorized circuit providing the bias voltage for the photomultiplier tube dynodes. This circuit was needed to obtain pulse-height linearity over the wide range of signal sizes. A special live-time clock was built to compensate for the large amount of dead time generated by the pulse-shape discrimination circuit we chose to use. 64 refs., 58 figs., 9 tabs.

  6. Detecting alpha radiation by scintillation in porous materials

    Energy Technology Data Exchange (ETDEWEB)

    Keillor, M.E. [McClellan Central Lab., McClellan AFB, CA (United States); Burggraf, L.W. [Air Force Inst. of Tech., Wright-Patterson AFB, OH (United States)

    1997-10-01

    This paper presents a study of some parameters essential to the development of a heterogeneous scintillation detector with improved alpha energy resolution and detection efficiency. Such a detector with better than 10% alpha energy resolution could provide in situ capability to identify and quantify important alpha-emitting radionuclides in dilute aqueous solutions. Nanoporous gel-silica is a potential scintillation matrix with the promise of improved energy resolution and 100% detection efficiency. Scintillating gel-silica made by a sol-gel process is under development. As a step toward realizing the system described, the dependence of alpha detection efficiency and intrinsic energy resolution in particulate and porous glass scintillation detectors is examined. The two main areas of this research are: (1) computer modeling of the geometric detection efficiency and energy dispersion in particulate and porous glass scintillation detectors and (2) experiments to test model predictions for detection of alphas in liquid-infiltrated porous glass structures. To confirm the predicted alpha energy deposition, the authors measured scintillation in nanoporous gel-silica infiltrated with an organic liquid scintillator. Results show that phase dimensions must be considered in constructing a heterogeneous detector for alpha spectroscopy. Nanometer-scale dimensions available in gel-silica essentially eliminate degradation of energy resolution due to energy dispersion of alpha particles within the liquid sample, while providing 100% detection efficiency.

  7. Preparation of 45Ca(HDEHP)n and (CaH{sub 1}50{sub 2})2 samples for liquid scintillation counting, compared to 45caCl{sub 2} results; Preparacion de Ca (HDEHP)n y (C{sub 8}H{sub 1}50{sub 2})2 marcados con 45Ca y estudio comparativo con 4 5ca Cl2 en medidas por centelleo liquido

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez, L.; Arcos, J. M. los; Grau Malonda, A.

    1994-07-01

    A procedure for preparation of liquid scintillation counting organic samples of the Di-2-ethylhexyl phosphate calcium complex and the 2-ethylhexanoate calcium salt, labelled with 45Ca, is described. The chemical quench, the counting stability and spectral evolution of both compounds is studied in six scintillators,Toluene-alcohol, Dioxane-naphtalene, Hi safe II, Ultimate-Gold and Instagel, and compared to results obtained from a commercial solution of 4 5CaCl2. (Author) 7 refs.

  8. Microfluidic Scintillation Detectors for High Energy Physics

    CERN Document Server

    Maoddi, Pietro; Mapelli, Alessandro

    This thesis deals with the development and study of microfluidic scintillation detectors, a technology of recent introduction for the detection of high energy particles. Most of the interest for such devices comes from the use of a liquid scintillator, which entails the possibility of changing the active material in the detector, leading to increased radiation resistance. A first part of the thesis focuses on the work performed in terms of design and modelling studies of novel prototype devices, hinting to new possibilities and applications. In this framework, the simulations performed to validate selected designs and the main technological choices made in view of their fabrication are addressed. The second part of this thesis deals with the microfabrication of several prototype devices. Two different materials were studied for the manufacturing of microfluidic scintillation detectors, namely the SU-8 photosensitive epoxy and monocrystalline silicon. For what concerns the former, an original fabrication appro...

  9. Scintillation properties of polycrystalline LaxY1-xO3 ceramic

    Science.gov (United States)

    Sahi, Sunil; Chen, Wei; Kenarangui, Rasool

    2015-03-01

    Scintillators are the material that absorbs the high-energy photons and emits visible photons. Scintillators are commonly used in radiation detector for security, medical imaging, industrial applications and high energy physics research. Two main types of scintillators are inorganic single crystals and organic (plastic or liquid) scintillators. Inorganic single crystals are expensive and difficult to grow in desire shape and size. Also, some efficient inorganic scintillator such as NaI and CsI are not environmental friendly. But on the other hand, organic scintillators have low density and hence poor energy resolution which limits their use in gamma spectroscopy. Polycrystalline ceramic can be a cost effective alternative to expensive inorganic single crystal scintillators. Here we have fabricated La0.2Y1.8O3 ceramic scintillator and studied their luminescence and scintillation properties. Ceramic scintillators were fabricated by vacuum sintering of La0.2Y1.8O3 nanoparticles at temperature below the melting point. La0.2Y1.8O3 ceramic were characterized structurally using XRD and TEM. Photoluminescence and radioluminescence studies were done using UV and X-ray as an excitation source. We have used gamma isotopes with different energy to studies the scintillation properties of La0.2Y1.8O3 scintillator. Preliminary studies of La0.2Y1.8O3 scintillator shows promising result with energy resolution comparable to that of NaI and CsI.

  10. An Experiment to Demonstrate Cherenkov / Scintillation Signal Separation

    CERN Document Server

    Caravaca, J; Land, B J; Wallig, J; Yeh, M; Gann, G D Orebi

    2016-01-01

    The ability to separately identify the Cherenkov and scintillation light components produced in scintillating mediums holds the potential for a major breakthrough in neutrino detection technology, allowing development of a large, low-threshold, directional detector with a broad physics program. The CHESS (CHErenkov / Scintillation Separation) experiment employs an innovative detector design with an array of small, fast photomultiplier tubes and state-of-the-art electronics to demonstrate the reconstruction of a Cherenkov ring in a scintillating medium based on photon hit time and detected photoelectron density. This paper describes the physical properties and calibration of CHESS along with first results. The ability to reconstruct Cherenkov rings is demonstrated in a water target, and a time precision of 338 +/- 12 ps FWHM is achieved. Monte Carlo based predictions for the ring imaging sensitivity with a liquid scintillator target predict an efficiency for identifying Cherenkov hits of 94 +/- 1% and 81 +/- 1...

  11. SR study of scintillators

    CERN Document Server

    Mikhailin, V V

    2000-01-01

    The technique and the models developed recently in Synchrotron Radiation (SR) Laboratory of Moscow University for the investigation of energy transfer processes in insulators can be applied for a detailed study of scintillator's properties. The experiments with SR in VUV and XUV regions allow to separate various processes and stages of energy transfer and help to indicate the dominating process on each stage. Thus, we can find the way to improve the properties, essential for the particular application of the scintillator: conversion efficiency, decay time, afterglow, radiation hardness, etc. The results of such a study can be used for the testing procedures in scintillator production.

  12. Measurement of the response function and the detection efficiency of an organic liquid scintillator for neutrons between 1 and 30 MeV

    Institute of Scientific and Technical Information of China (English)

    HUANG Han-Xiong; RUAN Xi-Chao; CHEN Guo-Chang; ZHOU Zu-Ying; LI Xia; BAO Jie; NIE Yang-Bo; ZHONG Qi-Ping

    2009-01-01

    The light output function of a φ50.8 mm×50.8 mm BC501A scintillation detector was measured in the neutron energy region of 1 to 30 MeV by fitting the pulse height (PH) spectra for neutrons with the simulations from the NRESP code at the edge range. Using the new light output function, the neutron detection efficiency was determined with two Monte-Carlo codes, NEFF and SCINFUL. The calculated efficiency was corrected by comparing the simulated PH spectra with the measured ones. The determined efficiency was verified at the near threshold region and normalized with a Proton-Recoil-Telescope (PRT) at the 8-14 MeV energy region.

  13. Design and Construction of the First Prototype of Liquid Scintillator Detector for Fast Beam Loss Monitor(FBLM) System%快响应束流损失监控(FBLM)系统液闪探测器初样的研制

    Institute of Scientific and Technical Information of China (English)

    韩晨霞; 陈昌; 田建民; 赵中亮; 徐美杭; 李公平; 陈元柏; 徐韬光; 赵海泉

    2011-01-01

    给出快响应束流损失监控(Fast Beam Lost Monitor,FBLM)系统的液体闪烁体探测器初样的研制.在高频四极加速器(Radio Frequency Quadrupole,RFQ)实验装置上的测试表明,液闪探测器能给出宽度为500 μs 束流宏脉冲结构,能逐个显示出宏脉冲内490 ns的束流切束脉冲.液闪输出信号脉冲较490 ns束流切束脉冲延迟约70 ns.液闪型FBLM输出的信号幅度大于塑闪型.液闪探测器初样的成功研制,为其性能进一步改进提高,打下了良好的基础.%Design and constmction of the first prototype of liquid scintillator detector for fast beam loss monitor ( FBLM ) system are given. A beam chopping device can remove a 490 ns section of beam at approximately 1 MHz repetition rate within a 500 μs macro beam pulse - width. The liquid scintillator displays the measured beam - pulse structure after the beam chopper. Through RFQ special beam structure, the response time of FBLM is measured. The response time of FBLM is about nano second. The signal amplitude from liquid scintillator is larger than plastic scintillator. All of these give us good experiences for the futher improvement of liquid seintillator detector design and construction. According to the measurement data. liquid seintillator is suggested as the detector of FBLM system.

  14. Light output of EJ228 scintillation neutron detectors

    Energy Technology Data Exchange (ETDEWEB)

    Stevanato, L., E-mail: luca.stevanato@pd.infn.i [Dipartimento di Fisica dell' Universita di Padova, Via Marzolo 8, I-35131 Padova (Italy); Fabris, D. [INFN Sezione di Padova, Via Marzolo 8, I-35131 Padova (Italy); Hao, Xin [Dipartimento di Fisica dell' Universita di Padova, Via Marzolo 8, I-35131 Padova (Italy); Lunardon, M.; Moretto, S. [Dipartimento di Fisica dell' Universita di Padova, Via Marzolo 8, I-35131 Padova (Italy); INFN Sezione di Padova, Via Marzolo 8, I-35131 Padova (Italy); Nebbia, G.; Pesente, S. [INFN Sezione di Padova, Via Marzolo 8, I-35131 Padova (Italy); Sajo-Bohus, L. [Universidad Simon-Bolivar, Laboratorio Fisica Nuclear, Apartado 8900, 1080 A. Caracas (Venezuela, Bolivarian Republic of); Viesti, G. [Dipartimento di Fisica dell' Universita di Padova, Via Marzolo 8, I-35131 Padova (Italy); INFN Sezione di Padova, Via Marzolo 8, I-35131 Padova (Italy)

    2011-02-15

    The light output of neutron detectors based on the plastic scintillator EJ228 is studied as a function of neutron energy using a time tagged {sup 252}Cf source. Calibration of the light output scale is performed by fitting the experimental distribution of Compton scattering events of photons from a {sup 22}Na source with a response function obtained by Gaussian smearing of the predicted line-shape. The light output curve as well as the pulse height resolution for the EJ228 scintillators is very close (within 5%) to those recently reported for NE213 type organic liquid scintillators.

  15. Study of n-γ discrimination for 0.4-1 MeV neutrons using the zero-crossing method with a BC501A liquid scintillation detector

    Institute of Scientific and Technical Information of China (English)

    CHEN Yong-Hao; LEI Jia-Rong; ZHANG Xiao-Dong; AN Li; ZHENG Pu; WANG Xin-Hua; ZHU Chuan-Xin

    2013-01-01

    An experimental system aimed at n-γ discrimination using the zero-crossing method with a φ3"× 2"BC501A liquid scintillation detector was established and tested with an Am-Be neutron source.Two-dimensional plots of energy versus zero-crossing time were obtained.The quality of n-γdiscrimination was checked by the figure-of-merit (FOM),the neutron peak-to-valley ratio,and the proportion of leaked neutrons over all neutron events.The performance of n-γ discrimination in terms of FOM was compared with previous work done by other groups.The n-γ discrimination in four different energy regions with an interval of 0.1 MeV between 0.3 MeV and 0.7 MeV was studied,and the results indicate that the n-γ discrimination threshold can go down to 0.4 MeV.

  16. Combination of chemical separation and data treatment for {sup 55}Fe, {sup 63}Ni, {sup 99}Tc, {sup 137}Cs and {sup 90}Sr/{sup 90}Y activity determination in radioactive waste by liquid scintillation

    Energy Technology Data Exchange (ETDEWEB)

    Mellado, J. [Departament de Quimica Analitica, Facultat de Quimica, Universitat de Barcelona, C/Marti Franques 1, 08028 Barcelona (Spain); Tarancon, A. [Departament de Quimica Analitica, Facultat de Quimica, Universitat de Barcelona, C/Marti Franques 1, 08028 Barcelona (Spain); Garcia, J.F. [Departament de Pintura, Facultat de Belles Arts, Universitat de Barcelona, C/Pau Gargallo 4, 08028 Barcelona (Spain)]. E-mail: jfgarcia@apolo.qui.ub.es; Rauret, G. [Departament de Quimica Analitica, Facultat de Quimica, Universitat de Barcelona, C/Marti Franques 1, 08028 Barcelona (Spain); Warwick, P. [Geoscience Advisory Unit, Southampton Oceanography Centre, Southampton SO14 3ZH (United Kingdom)

    2005-08-01

    Routine operations involving nuclear reactors and decommissioning activities require numerous chemical analyses. Most of the procedures developed for these chemical characterisations involve several separation steps to prepare the sample for measurement. Chemical treatments are time- and manpower-consuming, labour intensive and produce significant quantities of waste. In order to address this problem, we evaluate a data treatment procedure (multivariate calibration-PLS), which we propose as a substitute to some of these separation steps. Mixtures of beta emitter radionuclides of increasing complexity ({sup 90}Sr/{sup 90}Y-{sup 99}Tc, {sup 90}Sr/{sup 90}Y-{sup 99}Tc-{sup 63}Ni-{sup 137}Cs and {sup 90}Sr/{sup 90}Y-{sup 99}Tc-{sup 63}Ni-{sup 137}Cs-{sup 55}Fe) have been measured by liquid scintillation (LS) counting. The influences of quenching and level of activity was evaluated and the activity of unknown samples determined. Despite the spectra overlapping and low resolution of LS, relative errors in the activities quantification of unknown samples inside the range covered by the calibration matrix are lower than 15% whatever the number of radionuclides included in the solution was.

  17. Determination of total alpha and beta activity in water for human consumption by LSC(Liquid Scintillation Counter); Determinacao de atividades alfa e beta total em agua para consumo humano por LSC (Contador de Cintilacao Liquida))

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-07-01

    The Ordinance Brazilian of Ministry of Health (MS 2914/2011) establishes the standards for quality of water intended for human consumption, being limits values of 5.0 Bq/L for gross alpha, and 1.0 Bq/L for gross beta radioactivity. The liquid scintillation spectrometry (LSC) technique has been presented as an alternative to conventional procedure using gas flow proportional counter. The present work shows a review of the methods for determination of gross alpha and gross beta in water by using LSC. Between the factors that influence the accuracy and repeatability of the analytical results we can highlight: thermal preconcentration, type of the acid and calibration standard. A procedure was established and carried out to samples of the National Program of Intercomparison of Radionuclides in Environmental Samples for evaluation of its performance. The gross alpha and gross beta analysis in samples of the public water supplies in the Metropolitan Region of Goiania, state of Goias was carried out. The results are consistent with the guideline values form the Ministry of Health concerning radioactivity. (author)

  18. Research on the Progeny Volume Activity Measuring Method of 222 Rn with Liquid Scintillation Counting%氡子体体积活度的液体闪烁计数方法研究

    Institute of Scientific and Technical Information of China (English)

    杨志杰; 李则书; 侯胜利; 刘皓然; 张明; 梁珺成

    2015-01-01

    Based on liquid scintillation counting,a measuring method of 222 Rn progeny volume activity is established. Using this kind of method,measurements are executed in NIM’s radon chamber when 222 Rn and its progenies get to the secure equilibrium,and a typically expanded uncertainty of 1. 5%(k = 2)for the potential alpha energy concentration is obtained. Comparative measurements based on the alpha energy spectrum are also executed and the results of the two methods agree within the estimated uncertainty limit.%基于液体闪烁计数原理和滤膜采样技术,建立了一种氡(222 Rn)子体体积活度和α潜能浓度的测量方法。应用该方法对氡室中处于放射性平衡状态的氡子体体积活度进行了取样测量,氡子体α潜能浓度测量结果的扩展不确定度小于1.5%(k =2);用α能谱法对氡子体液体闪烁计数测量方法进行了旁证,两种方法的测量结果在不确定度范围内一致。

  19. Scintillation properties of acrylate based plastic scintillator by photoploymerization method

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung Hwan [Dept. of Radiological Science, Cheongju University, Cheongju (Korea, Republic of); Lee, Joo Il [Dept. of of Radiology, Daegu Health College, Daegu (Korea, Republic of)

    2016-12-15

    In this study, we prepared and characterized a acrylate based UV-curable plastic scintillator. It was used co-polymers TMPTA, DHPA and Ultima GoldTM LLT organic scintillator. The emission spectrum of the plastic scintillator was located in the range of 380⁓520 nm, peaking at 423 nm. And the scintillator is more than 50% transparent in the range of 400⁓ 800 nm. The emission spectrum is well match to the quantum efficiency of photo-multiplier tube and the fast decay time of the scintillation is 12 ns, approximately. This scintillation material provides the possibility of combining 3D printing technology, and then the applications of the plastic scintillator may be expected in human dosimetry etc.

  20. Calibration of radionuclides with decay trough beta emission or electron capture by liquid scintillation technique; Calibracao de radionuclideos que decaem por emissao beta ou por captura eletronica pela tecnica de cintilacao liquida

    Energy Technology Data Exchange (ETDEWEB)

    Loureiro, Jamir dos Santos

    2000-02-01

    In this work is reported a methodology a methodology for pure beta and electron capture radionuclides standardization, suing liquid scintillation technique. In this sense the CIEMAT/NIST method, recently utilized by international laboratories, was implemented and the lack in the Laboratorio Nacional das Radiacoes Ionizantes - LNMRI, of the Comissao Nacional de Energia Nuclear - CNEN, for adequate methodology to standardize this kind if radionuclides was filled, fact that was not present with alpha and gamma radionuclides. The implementation procedure evaluation was provided by concentration activity determination of the following radionuclides: {sup 14} C and {sup 90} Sr, pure beta emitters; {sup 55} Fe, electron capture decay; {sup 204} Tl, electron capture and beta decay and {sup 60} Co, beta-gamma emitter. In this way, a careful analysis of the implementation procedure with these radionuclides types, ranging on a broad energy spectral, was possible. To check the calibration results, intercomparisons among our measurements of these radionuclides and the reference values of the CIEMAT/Spain laboratory were provided. To check the calibration results, intercomparisons among our measurements of these radionuclides and the reference values of the CIEMAT/Spain laboratory were provided. Besides this intercomparisons, one was provided with a {sup 204} Tl solution, utilized in the international comparison recently promoted by BIPM, and another one with a {sup 60} C solution calibrated in LNMRI/CNEN previously by a relative calibration system, with a well type pressurized ionization chamber, and an absolute beta-gamma coincidence system, with a pill-box type proportional counter 4 {pi} geometry, coupled with a scintillator system with a sodium iodide cristal of 4x4 inches. The comparisons among LNMRI/CNEN results and the reference values, showed a small deviation of 1,32% for {sup 14} C, 0,40% for {sup 60} Co, 1,12% for {sup 55} Fe, 0,10% for {sup 90} Sr and 0,73% for {sup

  1. A Scintillator Purification Plant and Fluid Handling System for SNO+

    CERN Document Server

    Ford, Richard J

    2015-01-01

    A large capacity purification plant and fluid handling system has been constructed for the SNO+ neutrino and double-beta decay experiment, located 6800 feet underground at SNOLAB, Canada. SNO+ is a refurbishment of the SNO detector to fill the acrylic vessel with liquid scintillator based on Linear Alkylbenzene (LAB) and 2 g/L PPO, and also has a phase to load natural tellurium into the scintillator for a double-beta decay experiment with 130Te. The plant includes processes multi-stage dual-stream distillation, column water extraction, steam stripping, and functionalized silica gel adsorption columns. The plant also includes systems for preparing the scintillator with PPO and metal-loading the scintillator for double-beta decay exposure. We review the basis of design, the purification principles, specifications for the plant, and the construction and installations. The construction and commissioning status is updated.

  2. Neutron detection with single crystal organic scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Zaitseva, N; Newby, J; Hamel, S; Carman, L; Faust, M; Lordi, V; Cherepy, N; Stoeffl, W; Payne, S

    2009-07-15

    Detection of high-energy neutrons in the presence of gamma radiation background utilizes pulse-shape discrimination (PSD) phenomena in organics studied previously only with limited number of materials, mostly liquid scintillators and single crystal stilbene. The current paper presents the results obtained with broader varieties of luminescent organic single crystals. The studies involve experimental tools of crystal growth and material characterization in combination with the advanced computer modeling, with the final goal of better understanding the relevance between the nature of the organic materials and their PSD properties. Special consideration is given to the factors that may diminish or even completely obscure the PSD properties in scintillating crystals. Among such factors are molecular and crystallographic structures that determine exchange coupling and exciton mobility in organic materials and the impurity effect discussed on the examples of trans-stilbene, bibenzyl, 9,10-diphenylanthracene and diphenylacetylene.

  3. Neutron spectroscopy with scintillation detectors using wavelets

    Science.gov (United States)

    Hartman, Jessica

    The purpose of this research was to study neutron spectroscopy using the EJ-299-33A plastic scintillator. This scintillator material provided a novel means of detection for fast neutrons, without the disadvantages of traditional liquid scintillation materials. EJ-299-33A provided a more durable option to these materials, making it less likely to be damaged during handling. Unlike liquid scintillators, this plastic scintillator was manufactured from a non-toxic material, making it safer to use, as well as easier to design detectors. The material was also manufactured with inherent pulse shape discrimination abilities, making it suitable for use in neutron detection. The neutron spectral unfolding technique was developed in two stages. Initial detector response function modeling was carried out through the use of the MCNPX Monte Carlo code. The response functions were developed for a monoenergetic neutron flux. Wavelets were then applied to smooth the response function. The spectral unfolding technique was applied through polynomial fitting and optimization techniques in MATLAB. Verification of the unfolding technique was carried out through the use of experimentally determined response functions. These were measured on the neutron source based on the Van de Graff accelerator at the University of Kentucky. This machine provided a range of monoenergetic neutron beams between 0.1 MeV and 24 MeV, making it possible to measure the set of response functions of the EJ-299-33A plastic scintillator detector to neutrons of specific energies. The response of a plutonium-beryllium (PuBe) source was measured using the source available at the University of Nevada, Las Vegas. The neutron spectrum reconstruction was carried out using the experimentally measured response functions. Experimental data was collected in the list mode of the waveform digitizer. Post processing of this data focused on the pulse shape discrimination analysis of the recorded response functions to remove the

  4. Fast neutron spectrometry with organic scintillators applied to magnetic fusion experiments

    CERN Document Server

    Kaschuck, Y A; Trykov, L A; Semenov, V P

    2002-01-01

    Neutron spectrometry with NE213 liquid scintillators is commonly used in thermonuclear fusion experiments to measure the 2.45 and 14.1 MeV neutron flux. We present the unfolded neutron spectrum, which was accumulated during several ohmic deuterium plasma discharges in the Frascati Tokamak Upgrade using a 2''x2'' NE213 scintillator. In this paper, we review the application of organic scintillator neutron spectrometers to tokamaks, focusing in particular on the comparison between NE213 and stilbene scintillators. Various aspects of the calibration technique and neutron spectra unfolding procedure are considered in the context of their application for fusion neutron spectrometry. Testing and calibration measurements have been carried out using D-D and D-T neutron generator facilities with both NE213 and stilbene scintillators. The main result from these measurements is that stilbene scintillator has better neutron energy resolution than NE213. Our stilbene detector could be used for the determination of the ion ...

  5. Scintillation properties of solution-grown trans-stilbene single crystals

    Energy Technology Data Exchange (ETDEWEB)

    Zaitseva, Natalia, E-mail: zaitseva1@llnl.gov [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, CA 94551 (United States); Glenn, Andrew; Carman, Leslie; Paul Martinez, H.; Hatarik, Robert [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, CA 94551 (United States); Klapper, Helmut [Institut für Kristallographie, Jägerstraße 17-19, D-52066 Aachen (Germany); Payne, Stephen [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, CA 94551 (United States)

    2015-07-21

    The scintillation properties of trans-stilbene crystals grown for the first time by application of the solution growth technique to the scale of 10 cm are reported. Measurements of the scintillation light output, pulse shape discrimination, and neutron detection efficiency were made with sets of crystals cut as 50 cm diameter cylinders of different lengths from 0.3 to 10 cm. Comparison to liquid scintillators and traditional melt-grown stilbene showed that at increasing sizes new solution-grown crystals exhibit better scintillation performance that makes them promising for use in large scale neutron detectors. Results are discussed in relation to structural imperfections attributed to different methods of growth. - Highlights: • 10-cm-scale trans-stilbene single crystals grown from organic solutions. • Crystals have high optical quality required for fast neutron detection. • Scintillation performance superior to liquids and melt-grown stilbene demonstrated.

  6. PLASTIC SCINTILLATOR FOR RADIATION DOSIMETRY.

    Science.gov (United States)

    Kim, Yewon; Yoo, Hyunjun; Kim, Chankyu; Lim, Kyung Taek; Moon, Myungkook; Kim, Jongyul; Cho, Gyuseong

    2016-09-01

    Inorganic scintillators, composed of high-atomic-number materials such as the CsI(Tl) scintillator, are commonly used in commercially available a silicon diode and a scintillator embedded indirect-type electronic personal dosimeters because the light yield of the inorganic scintillator is higher than that of an organic scintillator. However, when it comes to tissue-equivalent dose measurements, a plastic scintillator such as polyvinyl toluene (PVT) is a more appropriate material than an inorganic scintillator because of the mass energy absorption coefficient. To verify the difference in the absorbed doses for each scintillator, absorbed doses from the energy spectrum and the calculated absorbed dose were compared. From the results, the absorbed dose of the plastic scintillator was almost the same as that of the tissue for the overall photon energy. However, in the case of CsI, it was similar to that of the tissue only for a photon energy from 500 to 4000 keV. Thus, the values and tendency of the mass energy absorption coefficient of the PVT are much more similar to those of human tissue than those of the CsI. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. A scintillator purification system for the Borexino solar neutrino detector

    Science.gov (United States)

    Benziger, J.; Cadonati, L.; Calaprice, F.; Chen, M.; Corsi, A.; Dalnoki-Veress, F.; Fernholz, R.; Ford, R.; Galbiati, C.; Goretti, A.; Harding, E.; Ianni, Aldo; Ianni, Andrea; Kidner, S.; Leung, M.; Loeser, F.; McCarty, K.; McKinsey, D.; Nelson, A.; Pocar, A.; Salvo, C.; Schimizzi, D.; Shutt, T.; Sonnenschein, A.

    2008-03-01

    Purification of the 278 tons of liquid scintillator and 889 tons of buffer shielding for the Borexino solar neutrino detector is performed with a system that combines distillation, water extraction, gas stripping, and filtration. This paper describes the principles of operation, design, and construction of that purification system, and reviews the requirements and methods to achieve system cleanliness and leak-tightness.

  8. Comparative analysis of two diffusion methods for radon Rn-222 estimation in atmospheric air by means of gamma-ray spectroscopy and liquid scintillation counting; Analiza porownawcza dwoch metod dyfuzyjnych pomiaru radonu Rn-222 w powietrzu z wykorzystaniem spektrometru promieni gamma i metody cieklej scyntylacji

    Energy Technology Data Exchange (ETDEWEB)

    Gorzkowski, B.; Pachocki, K.; Pensko, J.; Majle, T.; Rozycki, Z. [Panstwowy Zaklad Higieny, Warsaw (Poland)

    1995-12-31

    The comparative measurements of radon Rn-222 concentration in indoor air some buildings and in radon labour chamber have been conducted using two diffusions methods. The results of parallel measurements using radon charcoal detectors and gamma-ray spectroscopy with liquid alpha scintillation counting (Pico-Rad) have been presented. It was concluded that both methods offer the similar measurements possibilities of radon concentrations in the air from about 30 Bq/m{sup 3} to about 600 Bq/m{sup 3} with the real average divergence between both methods of about {+-}11%. (author). 10 refs, 6 figs, 1 tab.

  9. GPS Scintillation Analysis.

    Science.gov (United States)

    2007-11-02

    Rev. 2-89) Prescribed by ANSI Std. Z39-1 298-102 TABLE OF CONTENTS 1. INTRODUCTION 1 2. GPS COMPARISON WITH ALL-SKY IMAGES OVER AGUA VERDE...Depletions from 1 October 1994 2 3. GPS data from Agua Verde, Chile on the night of 1 October 1994 3 4. PL-SCINDA display of GPS ionospheric...comparison of GPS measurements with GOES8 L-band scintillation data, are discussed. 2. GPS COMPARISON WITH ALL-SKY IMAGES OVER AGUA VERDE, CHILE As

  10. Scintillating fiber detector

    CERN Document Server

    Vozak, Matous

    2016-01-01

    NA61 is one of the physics experiments at CERN dedicated to study hadron states coming from interactions of SPS beams with various targets. To determine the position of a secondary beam, three proportional chambers are placed along the beamline. However, these chambers tend to have slow response. In order to obtain more precise time information, use of another detector is being considered. Fast response and compact size is making scintillation fiber (SciFi) with silicon photomultiplier (Si-PM) read out a good candidate. This report is focused on analysing data from SciFi collected in a test beam at the beginning of July 2016.

  11. Hybrid scintillators for neutron discrimination

    Science.gov (United States)

    Feng, Patrick L; Cordaro, Joseph G; Anstey, Mitchell R; Morales, Alfredo M

    2015-05-12

    A composition capable of producing a unique scintillation response to neutrons and gamma rays, comprising (i) at least one surfactant; (ii) a polar hydrogen-bonding solvent; and (iii) at least one luminophore. A method including combining at least one surfactant, a polar hydrogen-bonding solvent and at least one luminophore in a scintillation cell under vacuum or an inert atmosphere.

  12. Proton induced radiation damage in fast crystal scintillators

    Science.gov (United States)

    Yang, Fan; Zhang, Liyuan; Zhu, Ren-Yuan; Kapustinsky, Jon; Nelson, Ron; Wang, Zhehui

    2016-07-01

    This paper reports proton induced radiation damage in fast crystal scintillators. A 20 cm long LYSO crystal, a 15 cm long CeF3 crystal and four liquid scintillator based sealed quartz capillaries were irradiated by 800 MeV protons at Los Alamos up to 3.3 ×1014 p /cm2. Four 1.5 mm thick LYSO plates were irradiated by 24 GeV protons at CERN up to 6.9 ×1015 p /cm2. The results show an excellent radiation hardness of LYSO crystals against charged hadrons.

  13. Determination of {sup 90}Sr, {sup 63}Ni and {sup 55}Fe activities by liquid scintillation counting in the environmental samples close to French nuclear power plants located on Loire and Garonne rivers

    Energy Technology Data Exchange (ETDEWEB)

    Rousseau, G.; Mokili, M.B.; Le Roy, C.; Deniau, I. [SUBATECH, IN2P3 (France); Gontier, G.; Boyer, C. [EDF-DPI-DIN-CIDEN (France); Hemidy, P.Y. [EDF-DPN-UNIE-GPRE-IEV (France); Chardon, P. [CNRS/IN2P3 (France)

    2014-07-01

    The protection of the aquatic and terrestrial environment from a wide range of radioactive contaminants released by nuclear industry requires continuous monitoring of radionuclides released into the environment. Specific measurement methods depending of the radionuclide are used to determinate this contribution. A lot of radionuclide can easily be measured at low level by gamma spectrometry, like {sup 137}Cs, {sup 60}Co..., but others like {sup 90}Sr, {sup 63}Ni or {sup 55}Fe require prior specific radiochemical separations. Activity of {sup 90}Sr values in environmental samples are available but only few measurements of {sup 63}Ni and {sup 55}Fe activities have been carried out in samples collected in the environment close to French nuclear power plants located on the Loire and Garonne rivers despite they represent 12% to 24% for {sup 63}Ni activity and <1% for {sup 55}Fe + other minor radionuclides of total activity of their liquid effluent discharges. {sup 90}Sr is not rejected by the liquid effluent discharges of Nuclear Power Plants and can be found in the environmental samples because of thermonuclear test and subsequently after the Chernobyl nuclear power plant accident. Considering the French Nuclear Power Plant located on Loire and Garonne rivers, the determination of {sup 90}Sr, {sup 63}Ni and {sup 55}Fe levels in the environmental samples around French nuclear power plants is carried out to detect the traces of these radionuclides originating from nuclear technology activities. The environment around five French nuclear Power Plants was investigated for 4 years between 2009 and 2014. The radionuclide activities determined by liquid scintillation counting after chemical steps were performed on a large set of various matrix samples likely to be encountered in environmental monitoring as soils, sediments, terrestrial and aquatic bio-indicators. It was found that the mean activity concentration of the most frequently detected was for the radionuclide {sup 90

  14. Development of Radiation Hard Scintillators

    CERN Document Server

    Tiras, Emrah; Bilki, Burak; Winn, David; Onel, Yasar

    2016-01-01

    Modern high-energy physics experiments are in ever increasing need for radiation hard scintillators and detectors. In this regard, we have studied various radiation-hard scintillating materials such as Polyethylene Naphthalate (PEN), Polyethylene Terephthalate (PET), our prototype material Scintillator X (SX) and Eljen (EJ). Scintillation and transmission properties of these scintillators are studied using stimulated emission from a 334 nm wavelength UV laser with PMT before and after certain amount of radiation exposure. Recovery from radiation damage is studied over time. While the primary goal of this study is geared for LHC detector upgrades, these new technologies could easily be used for future experiments such as the FCC and ILC. Here we discuss the physics motivation, recent developments and laboratory measurements of these materials.

  15. Antineutrino Geophysics with Liquid Scintillator Detectors

    CERN Document Server

    Rothschild, C G; Calaprice, F P; Rothschild, Casey G.; Chen, Mark C.; Calaprice, Frank P.

    1997-01-01

    Detecting the antineutrinos emitted by the decay of radioactive elements in the mantle and crust could provide a direct measurement of the total abundance of uranium and thorium in the Earth. In calculating the antineutrino flux at specific sites, the local geology of the crust and the background from the world's nuclear power reactors are important considerations. Employing a global crustal map, with type and thickness data, and using recent estimates of the uranium and thorium distribution in the Earth, we calculate the antineutrino event rate for two new neutrino detectors. We show that spectral features allow terrestrial antineutrino events to be identified above reactor antineutrino backgrounds and that the uranium and thorium contributions can be separately determined.

  16. Gadolinium-loaded gel scintillators for neutron and antineutrino detection

    Science.gov (United States)

    Riddle, Catherine Lynn; Akers, Douglas William; Demmer, Ricky Lynn; Paviet, Patricia Denise; Drigert, Mark William

    2016-11-29

    A gadolinium (Gd) loaded scintillation gel (Gd-ScintGel) compound allows for neutron and gamma-ray detection. The unique gel scintillator encompasses some of the best features of both liquid and solid scintillators, yet without many of the disadvantages associated therewith. Preferably, the gel scintillator is a water soluble Gd-DTPA compound and water soluble fluorophores such as: CdSe/ZnS (or ZnS) quantum dot (Q-dot) nanoparticles, coumarin derivatives 7-hydroxy-4-methylcoumarin, 7-hydroxy-4-methylcoumarin-3-acetic acid, 7-hydroxycoumarin-3-carboxylic acid, and Alexa Fluor 350 as well as a carbostyril compound, carbostyril 124 in a stable water-based gel, such as methylcellulose or polyacrylamide polymers. The Gd-loaded ScintGel allows for a homogenious distribution of the Gd-DTPA and the fluorophores, and yields clean fluorescent emission peaks. A moderator, such as deuterium or a water-based clear polymer, can be incorporated in the Gd-ScintGel. The gel scintillators can be used in compact detectors, including neutron and antineutrino detectors.

  17. Gadolinium-loaded gel scintillators for neutron and antineutrino detection

    Energy Technology Data Exchange (ETDEWEB)

    Riddle, Catherine Lynn; Akers, Douglas William; Demmer, Ricky Lynn; Paviet, Patricia Denise; Drigert, Mark William

    2016-11-29

    A gadolinium (Gd) loaded scintillation gel (Gd-ScintGel) compound allows for neutron and gamma-ray detection. The unique gel scintillator encompasses some of the best features of both liquid and solid scintillators, yet without many of the disadvantages associated therewith. Preferably, the gel scintillator is a water soluble Gd-DTPA compound and water soluble fluorophores such as: CdSe/ZnS (or ZnS) quantum dot (Q-dot) nanoparticles, coumarin derivatives 7-hydroxy-4-methylcoumarin, 7-hydroxy-4-methylcoumarin-3-acetic acid, 7-hydroxycoumarin-3-carboxylic acid, and Alexa Fluor 350 as well as a carbostyril compound, carbostyril 124 in a stable water-based gel, such as methylcellulose or polyacrylamide polymers. The Gd-loaded ScintGel allows for a homogenious distribution of the Gd-DTPA and the fluorophores, and yields clean fluorescent emission peaks. A moderator, such as deuterium or a water-based clear polymer, can be incorporated in the Gd-ScintGel. The gel scintillators can be used in compact detectors, including neutron and antineutrino detectors.

  18. First performance test of newly developed plastic scintillator for radiation detection

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, M., E-mail: minori@hep.sc.niigata-u.ac.jp [Graduate School of Science and Technology, Niigata University, Niigata 950-2181 (Japan); Katsumata, M. [Faculty of Science, Physics Department, Niigata University, Niigata 950-2181 (Japan); Ono, H. [Nippon Dental University, School of Life Dentistry at Niigata, Niigata 951-8580 (Japan); Suzuki, T. [Graduate School of Science and Technology, Niigata University, Niigata 950-2181 (Japan); Miyata, H. [Faculty of Science, Physics Department, Niigata University, Niigata 950-2181 (Japan); Itoh, Y.; Ishida, K. [Graduate School of Science and Technology, Niigata University, Niigata 950-2181 (Japan); Tamura, M.; Yamaguchi, Y. [Carlit Holdings Co., Ltd., Chiyoda, Tokyo 101-0024 (Japan)

    2015-01-11

    We present a plastic scintillator, developed in collaboration with Carlit Holdings Co., Ltd., that is fabricated using a liquid parent material cured at room temperature by adding a hardener. The new scintillator can incorporate heat-labile functional materials such as gadolinium to enhance neutron sensitivity. The characteristics of the new scintillator, in particular the light yield and attenuation length, were evaluated using a {sup 90}Sr β-ray source. The light yield was measured 7% Anthracene on the basis of a comparison with commercially available scintillator (BC-408) at a distance of 18 cm from the photodetector surface. This light yield is dependent on the distance between the luminous point and the photodetector because of light attenuation. The attenuation length of the Gd-doped scintillator was about 50 cm.

  19. Fracture-resistant lanthanide scintillators

    Science.gov (United States)

    Doty, F. Patrick

    2011-01-04

    Lanthanide halide alloys have recently enabled scintillating gamma ray spectrometers comparable to room temperature semiconductors (lanthanide alloy substitution, while preserving scintillation, have been demonstrated. Isovalent alloys having nominal compositions of comprising Al, Ga, Sc, Y, and In dopants as well as aliovalent alloys comprising Ca, Sr, Zr, Hf, Zn, and Pb dopants were prepared. All of these alloys exhibit bright fluorescence under UV excitation, with varying shifts in the spectral peaks and intensities relative to pure CeBr.sub.3. Further, these alloys scintillate when coupled to a photomultiplier tube (PMT) and exposed to .sup.137Cs gamma rays.

  20. Photon statistics in scintillation crystals

    Science.gov (United States)

    Bora, Vaibhav Joga Singh

    Scintillation based gamma-ray detectors are widely used in medical imaging, high-energy physics, astronomy and national security. Scintillation gamma-ray detectors are eld-tested, relatively inexpensive, and have good detection eciency. Semi-conductor detectors are gaining popularity because of their superior capability to resolve gamma-ray energies. However, they are relatively hard to manufacture and therefore, at this time, not available in as large formats and much more expensive than scintillation gamma-ray detectors. Scintillation gamma-ray detectors consist of: a scintillator, a material that emits optical (scintillation) photons when it interacts with ionization radiation, and an optical detector that detects the emitted scintillation photons and converts them into an electrical signal. Compared to semiconductor gamma-ray detectors, scintillation gamma-ray detectors have relatively poor capability to resolve gamma-ray energies. This is in large part attributed to the "statistical limit" on the number of scintillation photons. The origin of this statistical limit is the assumption that scintillation photons are either Poisson distributed or super-Poisson distributed. This statistical limit is often dened by the Fano factor. The Fano factor of an integer-valued random process is dened as the ratio of its variance to its mean. Therefore, a Poisson process has a Fano factor of one. The classical theory of light limits the Fano factor of the number of photons to a value greater than or equal to one (Poisson case). However, the quantum theory of light allows for Fano factors to be less than one. We used two methods to look at the correlations between two detectors looking at same scintillation pulse to estimate the Fano factor of the scintillation photons. The relationship between the Fano factor and the correlation between the integral of the two signals detected was analytically derived, and the Fano factor was estimated using the measurements for SrI2:Eu, YAP

  1. Ionospheric Scintillation Effects on GPS

    Science.gov (United States)

    Steenburgh, R. A.; Smithtro, C.; Groves, K.

    2007-12-01

    . Ionospheric scintillation of Global Positioning System (GPS) signals threatens navigation and military operations by degrading performance or making GPS unavailable. Scintillation is particularly active, although not limited to, a belt encircling the earth within 20 degrees of the geomagnetic equator. As GPS applications and users increases, so does the potential for detrimental impacts from scintillation. We examined amplitude scintillation data spanning seven years from Ascension Island, U.K.; Ancon, Peru; and Antofagasta, Chile in the Atlantic/Americas longitudinal sector at as well as data from Parepare, Indonesia; Marak Parak, Malaysia; Pontianak, Indonesia; Guam; and Diego Garcia, U.K.; in the Pacific longitudinal sector. From these data, we calculate percent probability of occurrence of scintillation at various intensities described by the S4 index. Additionally, we determine Dilution of Precision at one minute resolution. We examine diurnal, seasonal and solar cycle characteristics and make spatial comparisons. In general, activity was greatest during the equinoxes and solar maximum, although scintillation at Antofagasta, Chile was higher during 1998 rather than at solar maximum.

  2. Reconstruction of scintillations coordinates in cylindrical large detector with radial arrangement of photomultipliers

    CERN Document Server

    Alekseev, V M; Verbitskij, V S; Verbitskij, S S; Lapik, M A; Tselebrovskij, A N; Lapik, A M; Rusakov, A V; Savopulo, M L; Smirnov, V V; Chubarov, M N

    2002-01-01

    Paper describes algorithm to calculate scintillation coordinates elaborated for a coordinate-sensitive large detector based on liquid scintillator with radial arrangement of nine FEU-174 photomultipliers. Paper contains the simulation results of coordinate resolution dependence in detector centre on energy of gamma-quanta within 0.2-8 MeV range. Using this algorithm one processed the experimental data obtained with application of sup 6 sup 0 Co gamma-radiation source and the results of determination of scintillation coordinates for gamma-quanta beam. The accuracy of coordinate determination in detector centre when applying the descried algorithm constitutes approx 10 mm

  3. Calculation of the detection efficiency in liquid scintillators. II. Single positron emitters; Calculo de la eficiencia de deteccion en liquidos centelleadores. II Nucleidos que se desintegran por emision simple de positrones

    Energy Technology Data Exchange (ETDEWEB)

    Grau Malonda, A.; Garcia Torano, E.

    1982-07-01

    Counting efficiency as a function of the figure of merit for 30 positron emitters has been computed from the positron energy spectrum. Only the efficiency contribution of positrons has been taken into consideration. The contribution of the annihilation photons depending on the volume of the scintillator will be investigated in a near future. Efficiency vs figure of merit is plotted and tabulated. (Author) 19 refs.

  4. The theory and practice of scintillation counting

    CERN Document Server

    Birks, John Bettely

    1964-01-01

    The Theory and Practice of Scintillation Counting is a comprehensive account of the theory and practice of scintillation counting. This text covers the study of the scintillation process, which is concerned with the interactions of radiation and matter; the design of the scintillation counter; and the wide range of applications of scintillation counters in pure and applied science. The book is easy to read despite the complex nature of the subject it attempts to discuss. It is organized such that the first five chapters illustrate the fundamental concepts of scintillation counting. Chapters 6

  5. Characterization of cerium fluoride nanocomposite scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Stange, Sy [Los Alamos National Laboratory; Esch, Ernst I [Los Alamos National Laboratory; Brown, Leif O [Los Alamos National Laboratory; Couture, Aaron J [Los Alamos National Laboratory; Mckigney, Edward A [Los Alamos National Laboratory; Muenchausen, Ross E [Los Alamos National Laboratory; Del Sesto, Rico E [Los Alamos National Laboratory; Gilbertson, Robert D [Los Alamos National Laboratory; Mccleskey, T Mark [Los Alamos National Laboratory; Reifarth, Rene [Los Alamos National Laboratory

    2009-01-01

    Measurement of the neutron capture cross-sections of a number of short-lived isotopes would advance both pure and applied scientific research. These cross-sections are needed for calculation of criticality and waste production estimates for the Advanced Fuel Cycle Initiative, for analysis of data from nuclear weapons tests, and to improve understanding of nucleosynthesis. However, measurement of these cross-sections would require a detector with a faster signal decay time than those used in existing neutron capture experiments. Crystals of faster detector materials are not available in sufficient sizes and quantities to supply these large-scale experiments. Instead, we propose to use nanocomposite detectors, consisting of nanoscale particles of a scintillating material dispersed in a matrix material. We have successfully fabricated cerium fluoride (CeF{sub 3}) nanoparticles and dispersed them in a liquid matrix. We have characterized this scintillator and have measured its response to neutron capture. Results of the optical, structural, and radiation characterization will be presented.

  6. Application of a free parameter model to plastic scintillation samples

    Energy Technology Data Exchange (ETDEWEB)

    Tarancon Sanz, Alex, E-mail: alex.tarancon@ub.edu [Departament de Quimica Analitica, Universitat de Barcelona, Diagonal 647, E-08028 Barcelona (Spain); Kossert, Karsten, E-mail: Karsten.Kossert@ptb.de [Physikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, 38116 Braunschweig (Germany)

    2011-08-21

    In liquid scintillation (LS) counting, the CIEMAT/NIST efficiency tracing method and the triple-to-double coincidence ratio (TDCR) method have proved their worth for reliable activity measurements of a number of radionuclides. In this paper, an extended approach to apply a free-parameter model to samples containing a mixture of solid plastic scintillation microspheres and radioactive aqueous solutions is presented. Several beta-emitting radionuclides were measured in a TDCR system at PTB. For the application of the free parameter model, the energy loss in the aqueous phase must be taken into account, since this portion of the particle energy does not contribute to the creation of scintillation light. The energy deposit in the aqueous phase is determined by means of Monte Carlo calculations applying the PENELOPE software package. To this end, great efforts were made to model the geometry of the samples. Finally, a new geometry parameter was defined, which was determined by means of a tracer radionuclide with known activity. This makes the analysis of experimental TDCR data of other radionuclides possible. The deviations between the determined activity concentrations and reference values were found to be lower than 3%. The outcome of this research work is also important for a better understanding of liquid scintillation counting. In particular the influence of (inverse) micelles, i.e. the aqueous spaces embedded in the organic scintillation cocktail, can be investigated. The new approach makes clear that it is important to take the energy loss in the aqueous phase into account. In particular for radionuclides emitting low-energy electrons (e.g. M-Auger electrons from {sup 125}I), this effect can be very important.

  7. Molecular origins of scintillation in organic scintillators (Conference Presentation)

    Science.gov (United States)

    Feng, Patrick; Mengesha, Wondwosen; Myllenbeck, Nicholas

    2016-09-01

    Organic-based scintillators are indispensable materials for radiation detection owing to their high sensitivity to fast neutrons, low cost, and tailorable properties. There has been a recent resurgence of interest in organic scintillators due to exciting discoveries related to neutron discrimination and gamma-ray spectroscopy, which represent capabilities previously thought not possible in these materials. I will discuss our development of crystalline and polymer-based scintillators for these applications. Structure-property relationships related to intermolecular interactions and host-guest electronic exchange will be discussed in the context of energy-transfer pathways relevant to scintillation. An emphasis will be placed on the rational design of these materials, as guided by first principles and DFT calculations. Two related topics will be discussed: 1) Incorporation of organometallic triplet-harvesting additives to plastic scintillator matrices to confer a 'two-state' (singlet and triplet) luminescence signature to different types of ionizing radiation. This approach relies upon energetic and spatial overlap between the donor and acceptor excited states for efficient electronic exchange. Key considerations also include synthetic modification of the luminescence spectra and kinetics, as well as the addition of secondary additives to increase the recombination efficiency. 2) Design of organotin-containing plastic scintillators as a route towards gamma-ray spectroscopy. Organometallic compounds were selected on the basis of distance-dependent quenching relationships, phase compatibility with the polymer matrix, and the gamma-ray cross sections. This approach is guided by molecular modeling and radiation transport modeling to achieve the highest possible detection sensitivity luminescence intensity.

  8. New halide scintillators for gamma ray detection

    NARCIS (Netherlands)

    Alekhin, M. S.

    2013-01-01

    Scintillators are used for the detection of ionizing radiation. Despite decades of intensive search and numerous compounds discovered, there is still a need for materials with improved properties. Recently, several new scintillators with excellent light yield, energy resolution, and proportionality

  9. Scintillation-Hardened GPS Receiver

    Science.gov (United States)

    Stephens, Donald R.

    2015-01-01

    CommLargo, Inc., has developed a scintillation-hardened Global Positioning System (GPS) receiver that improves reliability for low-orbit missions and complies with NASA's Space Telecommunications Radio System (STRS) architecture standards. A software-defined radio (SDR) implementation allows a single hardware element to function as either a conventional radio or as a GPS receiver, providing backup and redundancy for platforms such as the International Space Station (ISS) and high-value remote sensing platforms. The innovation's flexible SDR implementation reduces cost, weight, and power requirements. Scintillation hardening improves mission reliability and variability. In Phase I, CommLargo refactored an open-source GPS software package with Kalman filter-based tracking loops to improve performance during scintillation and also demonstrated improved navigation during a geomagnetic storm. In Phase II, the company generated a new field-programmable gate array (FPGA)-based GPS waveform to demonstrate on NASA's Space Communication and Navigation (SCaN) test bed.

  10. Ionospheric precursors to scintillation activity

    Directory of Open Access Journals (Sweden)

    Paul S.J. Spencer

    2014-03-01

    Full Text Available Ionospheric scintillation is the rapid fluctuation of both phase and amplitude of trans-ionospheric radio waves due to small scale electron density irregularities in the ionosphere. Prediction of the occurrence of scintillation at L band frequencies is needed to mitigate the disruption of space-based communication and navigation systems. The purpose of this paper is to present a method of using tomographic inversions of the ionospheric electron density obtained from ground-based GPS data to infer the location and strength of the post-sunset plasma drift vortex. This vortex is related to the pre-reversal enhancement in the eastwards electric field which has been correlated to the subsequent occurrence of scintillation.

  11. Scintillation detectors in computerized tomography

    Energy Technology Data Exchange (ETDEWEB)

    Gilar, O.; Pavlicek, Z.; Jursova, L. (Tesla, Premysleni (Czechoslovakia). Vyzkumny Ustav Pristroju Jaderne Techniky)

    1984-07-01

    A new scintillator, Bi/sub 4/Ge/sub 3/O/sub 12/ (BGO), was tested for use in the detection part of computerized tomographs. In comparison with the NaI(Tl) scintillator it has a three-fold mass stopping power and allows the detection of medium and high energy gamma radiation with a higher detection efficiency, i.e., for the same detection efficiency its size is much smaller. Some other mechanical, physical and optical parameters of the BGO scintillator are given. BGO is prospective for use in high energy spectrometry and may replace NaI(Tl) wherever the following parameters are significant: crystal size, detection efficiency for gamma radiation, and good spatial resolution.

  12. Development of novel UV emitting single crystalline film scintillators

    Science.gov (United States)

    Zorenko, Yu; Gorbenko, V.; Savchyn, V.; Voznyak, T.; Nikl, M.; Mares, J. A.; Martin, T.; Douissard, P.-A.

    2011-04-01

    The work is dedicated to development of new types of UV -emitting scintillators based on single crystalline films (SCF) of aluminimum perovskites and garnets grown by the liquid phase epitaxy (LPE) method. The development of the following three types of UV SCF scintillators is considered in this work: i) Ce-doped SCF of Y-Lu-Al-perovskites with Ce3+ emission in the 360-370 nm range with a decay time of 16-17 ns; ii) Pr-doped SCF of Y-Lu-Al garnets with Pr3+ emission in the 300-400 nm range with a decay time of 13-17 ns; iii) La3+ and Sc3+ doped SCF of Y-Lu-Al-garnets, emitting in the 290-400 nm range due to formation of the LaY,Lu, ScY,Lu and ScAl centers with decay time of 250-575 ns. The results of testing the several novel UV-emitting SCFs scintillators for visualization of X-ray images at ESFR are presented. It is shown that the UV emission of the LuAG:Sc, LuAG:La and LuAG:Pr SCFs is efficient enough for conversion of X-ray to the UV light and that these scintillators can be used for improvement of the resolution of imaging detectors in synchrotron radiation applications.

  13. Optical artefact characterization and correction in volumetric scintillation dosimetry

    Science.gov (United States)

    Robertson, Daniel; Hui, Cheukkai; Archambault, Louis; Mohan, Radhe; Beddar, Sam

    2014-01-01

    The goals of this study were (1) to characterize the optical artefacts affecting measurement accuracy in a volumetric liquid scintillator detector, and (2) to develop methods to correct for these artefacts. The optical artefacts addressed were photon scattering, refraction, camera perspective, vignetting, lens distortion, the lens point spread function, stray radiation, and noise in the camera. These artefacts were evaluated by theoretical and experimental means, and specific correction strategies were developed for each artefact. The effectiveness of the correction methods was evaluated by comparing raw and corrected images of the scintillation light from proton pencil beams against validated Monte Carlo calculations. Blurring due to the lens and refraction at the scintillator tank-air interface were found to have the largest effect on the measured light distribution, and lens aberrations and vignetting were important primarily at the image edges. Photon scatter in the scintillator was not found to be a significant source of artefacts. The correction methods effectively mitigated the artefacts, increasing the average gamma analysis pass rate from 66% to 98% for gamma criteria of 2% dose difference and 2 mm distance to agreement. We conclude that optical artefacts cause clinically meaningful errors in the measured light distribution, and we have demonstrated effective strategies for correcting these optical artefacts.

  14. First approach to radionuclide mixtures quantification by using plastic scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Tarancon, A. [Departament de Quimica Analitica, Universitat de Barcelona, Diagonal 647, E-08028 Barcelona (Spain); Garcia, J.F. [Departament de Pintura, Universitat de Barcelona, Pau Gargallo 4, E-08028 Barcelona (Spain)]. E-mail: jfgarcia@ub.edu; Rauret, G. [Departament de Quimica Analitica, Universitat de Barcelona, Diagonal 647, E-08028 Barcelona (Spain)

    2007-05-08

    Recent studies have evaluated the capability of plastic scintillation (PS) as an alternative to liquid scintillation (LS) in radionuclide activity determination without mixed waste production. In order to complete the comparison, we now assess the extent to which PS can be used to quantify mixtures of radionuclides and the influence of the diameter of the plastic scintillation beads in detection efficiency. The results show that the detection efficiency decreases and the spectrum shrink to lower energies when the size of the plastic scintillation beads increases, and that the lower the energy of the beta particle, the greater the variation takes place. Similar behaviour has been observed for beta-gamma and alpha emitters. Two scenarios for the quantification of mixtures are considered, one including two radionuclides ({sup 14}C and {sup 60}Co) whose spectra do not overlap significantly, and the other including two radionuclides ({sup 137}Cs and {sup 90}Sr/{sup 90}Y), where the spectra of one the isotopes is totally overlapped by the other The calculation has been performed by using the conventional window selection procedure and a new approach in which the selected windows correspond to those with lower quantification errors. Relative errors obtained using the proposed approach (less than 10%) are lower than those of the conventional procedure, even when a radionuclide is completely overlapped, except for those samples with extreme activity ratios that were not included in the window optimization process.

  15. Study of a method of detection for natural carbon-14 using a liquid scintillator, recent variations in the natural radio-activity due to artificial carbon-14 (1963); Etude d'une methode de detection du carrons 14 naturel, utilisant un scintillateur liquide - variations recentes de l'activite naturelle dues au carbone 14 artificiel (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Leger, C. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1963-06-15

    Among the various natural isotopes of carbon, a radioactive isotope, carbon-14, is formed by the action of secondary neutrons from cosmic rays on nitrogen in the air. Until 1950, the concentration of this isotope in ordinary carbon underwent weak fluctuations of about 2-3 per cent. The exact measurement of this concentration 6 X 10{sup 12} Ci/gm of carbon, and of its fluctuations, are difficult and in the first part of this report a highly sensitive method is given using a liquid scintillator. Since 1950 this natural activity has shown large fluctuations because of the carbon-14 formed during nuclear explosions, and in the second part, the evolution in France of this specific activity of carbon in the atmosphere and biosphere is examined. In the last part is studied the local increase in carbon activity in the atmosphere around the Saclay site, an increase caused by the carbon-14 given off as C{sup 14}O{sub 2}, by the reactors cooled partially with exterior air. (author) [French] Parmi les differents isotopes naturels du carbone, un isotope radioactif, le carbone 14, est forme par l'action de neutrons secondaires due aux rayons cosmiques sir l'azote de l'air. Jusqu'en 1950, la concentration de cet isotope dans le carbone ordinaire est soumise a des fluctuations de faible amplitude, de l'ordre de 2 a 3 pour cent. Les mesures precises de cette concentration, 6. 10{sup -12} Ci/g de carbone, et de ses fluctuations sont delicates, et dans la premiere partie de ce rapport, on decrit une methode de detection a grande sensibilite utilisant un scintillateur liquide. Depuis 1950, cette activite naturelle subit des fluctuations importantes dues au carbone 14 forme lors des explosions nucleaires, et dans la seconde partie, on examine l'evolution en France de l'activite specifique du carbone de l'atmosphere et ce la biosphere. Dans la derniere partie, on etudie l'accroissement local de l'activite du carbone de l'air aux

  16. Composite scintillators for detection of ionizing radiation

    Science.gov (United States)

    Dai, Sheng [Knoxville, TN; Stephan, Andrew Curtis [Knoxville, TN; Brown, Suree S [Knoxville, TN; Wallace, Steven A [Knoxville, TN; Rondinone, Adam J [Knoxville, TN

    2010-12-28

    Applicant's present invention is a composite scintillator having enhanced transparency for detecting ionizing radiation comprising a material having optical transparency wherein said material comprises nano-sized objects having a size in at least one dimension that is less than the wavelength of light emitted by the composite scintillator wherein the composite scintillator is designed to have selected properties suitable for a particular application.

  17. Photonic crystal scintillators and methods of manufacture

    Science.gov (United States)

    Torres, Ricardo D.; Sexton, Lindsay T.; Fuentes, Roderick E.; Cortes-Concepcion, Jose

    2015-08-11

    Photonic crystal scintillators and their methods of manufacture are provided. Exemplary methods of manufacture include using a highly-ordered porous anodic alumina membrane as a pattern transfer mask for either the etching of underlying material or for the deposition of additional material onto the surface of a scintillator. Exemplary detectors utilizing such photonic crystal scintillators are also provided.

  18. Melt-cast organic glasses as high-efficiency fast neutron scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Carlson, Joseph S.; Feng, Patrick L., E-mail: plfeng@sandia.gov

    2016-10-01

    In this work we report a new class of organic-based scintillators that combines several of the desirable attributes of existing crystalline, liquid, and plastic organic scintillators. The prepared materials may be isolated in single crystalline form or melt-cast to produce highly transparent glasses that have been shown to provide high light yields of up to 16,000 photons/MeVee, as evaluated against EJ-200 plastic scintillators and solution-grown trans-stilbene crystals. The prepared organic glasses exhibit neutron/gamma pulse-shape discrimination (PSD) and are compatible with wavelength shifters to reduce optical self-absorption effects that are intrinsic to pure materials such as crystalline organics. The combination of high scintillation efficiency, PSD capabilities, and facile scale-up via melt-casting distinguishes this new class of amorphous materials from existing alternatives.

  19. Neutron detection with noble gas scintillation: a review of recent results

    Science.gov (United States)

    Lavelle, C. M.; Coplan, Michael; Miller, Eric C.; Thompson, Alan K.; Kowler, Alex; Vest, Rob; Yue, Andrew; Koeth, Tim; Al-Sheikhly, Mohammad; Clark, Charles

    2015-08-01

    Thermal neutron detection is of vital importance to many disciplines, including neutron scattering, workplace monitoring, and homeland protection. We survey recent results from our collaboration which couple low-pressure noble gas scintillation with novel approaches to neutron absorbing materials and geometries to achieve potentially advantageous detector concepts. Noble gas scintillators were used for neutron detection as early as the late 1950's. Modern use of noble gas scintillation includes liquid and solid forms of argon and xenon in the dark matter and neutron physics experiments and commercially available high pressure applications have achieved high resolution gamma ray spectroscopy. Little attention has been paid to the overlap between low pressure noble gas scintillation and thermal neutron detection, for which there are many potential benefits.

  20. Extruded plastic scintillator for MINERvA

    Energy Technology Data Exchange (ETDEWEB)

    Pla-Dalmau, Anna; Bross, Alan D.; /Fermilab; Rykalin, Victor V.; Wood, Brian M.; /NICADD, DeKalb

    2005-11-01

    An extrusion line has recently been installed at Fermilab in collaboration with NICADD (Northern Illinois Center for Accelerator and Detector Development). This new facility will serve to further develop and improve extruded plastic scintillator. Since polystyrene is widely used in the consumer industry, the logical path was to investigate the extrusion of commercial-grade polystyrene pellets with dopants to yield high quality plastic scintillator. The D0 and MINOS experiments are already using extruded scintillator strips in their detectors. A new experiment at Fermilab is pursuing the use of extruded plastic scintillator. A new plastic scintillator strip is being tested and its properties characterized. The initial results are presented here.

  1. New Scintillation Detectors for PET

    NARCIS (Netherlands)

    Shah, K.S.

    2010-01-01

    The focus of this thesis is on new detection technologies that can be used in advancing nuclear medicine modalities, particularly positron emission tomography (PET). Several detection technologies are covered in this thesis. First, new Ce3+ doped rare earth trihalide scintillators that can be used

  2. New Scintillation Detectors for PET

    NARCIS (Netherlands)

    Shah, K.S.

    2010-01-01

    The focus of this thesis is on new detection technologies that can be used in advancing nuclear medicine modalities, particularly positron emission tomography (PET). Several detection technologies are covered in this thesis. First, new Ce3+ doped rare earth trihalide scintillators that can be used i

  3. Complex Dynamics of Equatorial Scintillation

    Science.gov (United States)

    Piersanti, Mirko; Materassi, Massimo; Forte, Biagio; Cicone, Antonio

    2017-04-01

    Radio power scintillation, namely highly irregular fluctuations of the power of trans-ionospheric GNSS signals, is the effect of ionospheric plasma turbulence. The scintillation patterns on radio signals crossing the medium inherit the ionospheric turbulence characteristics of inter-scale coupling, local randomness and large time variability. On this basis, the remote sensing of local features of the turbulent plasma is feasible by studying radio scintillation induced by the ionosphere. The distinctive character of intermittent turbulent media depends on the fluctuations on the space- and time-scale statistical properties of the medium. Hence, assessing how the signal fluctuation properties vary under different Helio-Geophysical conditions will help to understand the corresponding dynamics of the turbulent medium crossed by the signal. Data analysis tools, provided by complex system science, appear to be best fitting to study the response of a turbulent medium, as the Earth's equatorial ionosphere, to the non-linear forcing exerted by the Solar Wind (SW). In particular we used the Adaptive Local Iterative Filtering, the Wavelet analysis and the Information theory data analysis tool. We have analysed the radio scintillation and ionospheric fluctuation data at low latitude focusing on the time and space multi-scale variability and on the causal relationship between forcing factors from the SW environment and the ionospheric response.

  4. Organic scintillators with pulse shape discrimination for detection of radiation (Conference Presentation)

    Science.gov (United States)

    Mabe, Andrew; Carman, M. Leslie; Glenn, Andrew M.; Zaitseva, Natalia P.; Payne, Stephen A.

    2016-09-01

    The detection of neutrons in the presence of gamma-ray fields has important applications in the fields of nuclear physics, homeland security, and medical imaging. Organic scintillators provide several attractive qualities as neutron detection materials including low cost, fast response times, ease of scaling, and the ability to implement pulse shape discrimination (PSD) to discriminate between neutrons and gamma-rays. This talk will focus on amorphous organic scintillators both in plastic form and small-molecule organic glass form. The first section of this talk will describe recent advances and improvements in the performance of PSD-capable plastic scintillators. The primary advances described in regard to modification of the polymer matrix, evaluation of new scintillating dyes, improved fabrication conditions, and implementation of additives which impart superior performance and mechanical properties to PSD-capable plastics as compared to commercially-available plastics and performance comparable to PSD-capable liquids. The second section of this talk will focus on a class of small-molecule organic scintillators based on modified indoles and oligophenylenes which form amorphous glasses as PSD-capable neutron scintillation materials. Though indoles and oligophenylenes have been known for many decades, their PSD properties have not been investigated and their scintillation properties only scantily investigated. Well-developed synthetic methodologies have permitted the synthesis of a library of structural analogs of these compounds as well as the investigation of their scintillation properties. The emission wavelengths of many indoles are in the sensitive region of common photomultiplier tubes, making them appropriate to be used as scintillators in either pure or doped form. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344. This work has been supported by the U

  5. Position Reconstruction in a Dual Phase Xenon Scintillation Detector

    CERN Document Server

    Solovov, V N; Akimov, D Yu; Araújo, H M; Barnes, E J; Burenkov, A A; Chepel, V; Currie, A; DeViveiros, L; Edwards, B; Ghag, C; Hollingsworth, A; Horn, M; Kalmus, G E; Kobyakin, A S; Kovalenko, A G; Lebedenko, V N; Lindote, A; Lopes, M I; Lüscher, R; Majewski, P; Murphy, A St J; Neves, F; Paling, S M; da Cunha, J Pinto; Preece, R; Quenby, J J; Reichhart, L; Scovell, P R; Silva, C; Smith, N J T; Smith, P F; Stekhanov, V N; Sumner, T J; Thorne, C; Walker, R J

    2011-01-01

    We studied the application of statistical reconstruction algorithms, namely maximum likelihood and least squares methods, to the problem of event reconstruction in a dual phase liquid xenon detector. An iterative method was developed for in-situ reconstruction of the PMT light response functions from calibration data taken with an uncollimated gamma-ray source. Using the techniques described, the performance of the ZEPLIN-III dark matter detector was studied for 122 keV gamma-rays. For the inner part of the detector (R<100 mm), spatial resolutions of 13 mm and 1.6 mm FWHM were measured in the horizontal plane for primary and secondary scintillation, respectively. An energy resolution of 8.1% FWHM was achieved at that energy. The possibility of using this technique for improving performance and reducing cost of scintillation cameras for medical applications is currently under study.

  6. Design, Construction and Installation of the ATLAS Hadronic Barrel Scintillator-Tile Calorimeter

    CERN Document Server

    Abdallah, J; Alexa, C; Alves, R; Amaral, P; Ananiev, A; Anderson, K; Andresen, X; Antonaki, A; Batusov, V; Bednar, P; Bergeaas, E; Biscarat, C; Blanch, O; Blanchot, G; Bohm, C; Boldea, V; Bosi, F; Bosman, M; Bromberg, C; Budagov, Yu A; Calvet, D; Cardeira, C; Carli, T; Carvalho, J; Cascella, M; Castillo, M V; Costello, J; Cavalli-Sforza, M; Cavasinni, V; Cerqueira, A S; Clément, C; Cobal, M; Cogswell, F; Constantinescu, S; Costanzo, D; Da Silva, P; Davidek, M; David, T; Dawson, J; De, K; Del Prete, T; Di Girolamo, B; Dita, S; Dolejsi, J; Dolezal, Z; Dotti, A; Downing, R; Drake, G; Efthymiopoulos, I; Errede, D; Errede, S; Farbin, A; Fassouliotis, D; Feng, E; Fenyuk, A; Ferdi, C; Ferreira, B C; Ferrer, A; Flaminio, V; Flix, J; Francavilla, P; Fullana, E; Garde, V; Gellerstedt, K; Giakoumopoulou, V; Giangiobbe, V; Gildemeister, O; Gilewsky, V; Giokaris, N; Gollub, N; Gomes, A; González, V; Gouveia, J; Grenier, P; Gris, P; Guarino, V; Guicheney, C; Sen-Gupta, A; Hakobyan, H; Haney, M; Hellman, S; Henriques, A; Higón, E; Hill, N; Holmgren, S; Hruska, I; Hurwitz, M; Huston, J; Jen-La Plante, I; Jon-And, K; Junk, T; Karyukhin, A; Khubua, J; Klereborn, J; Kopikov, S; Korolkov, I; Krivkova, P; Kulchitsky, Y; Kurochkin, Yu; Kuzhir, P; Lapin, V; Le Compte, T; Lefèvre, R; Leitner, R; Li, J; Liablin, M; Lokajícek, M; Lomakin, Y; Lourtie, P; Lovas, L; Lupi, A; Maidantchik, C; Maio, A; Maliukov, S; Manousakis, A; Marques, C; Marroquim, F; Martin, F; Mazzoni, E; Merritt, F S; Myagkov, A; Miller, R; Minashvili, I; Miralles, L; Montarou, G; Némécek, S; Nessi, M; Nikitine, I; Nodulman, L; Norniella, O; Onofre, A; Oreglia, M; Palan, B; Pallin, D; Pantea, D; Pereira, A; Pilcher, J E; Pina, J; Pinhão, J; Pod, E; Podlyski, F; Portell, X; Poveda, J; Pribyl, L; Price, L E; Proudfoot, J; Ramalho, M; Ramstedt, M; Raposeiro, L; Reis, J; Richards, R; Roda, C; Romanov, V; Rosnet, P; Roy, P; Ruiz, A; Rumiantsau, V; Russakovich, N; Sada Costa, J; Salto, O; Salvachúa, B; Sanchis, E; Sanders, H; Santoni, C; Santos, J; Saraiva, J G; Sarri, F; Says, L P; Schlager, G; Schlereth, J L; Seixas, J M; Selldén, B; Shalanda, N; Shevtsov, P; Shochet, M; Simaitis, V; Simonyan, M; Sisakian, A; Sjölin, J; Solans, C; Solodkov, A; Solovianov, J; Silva, O; Sosebee, M; Spanó, F; Speckmeyer, P; Stanek, R; Starchenko, E; Starovoitov, P; Suk, M; Sykora, I; Tang, F; Tas, P; Teuscher, R; Tokar, S; Topilin, N; Torres, J; Underwood, D; Usai, G; Valero, A; Valkár, S; Valls, J A; Vartapetian, A; Vazeille, F; Vellidis, C; Ventura, F; Vichou, I; Vivarelli, I; Volpi, M; White, A; Zaitsev, A; Zenin, A; Zenis, T; Zenonos, Z; Zenz, S; Zilka, B

    2007-01-01

    The scintillator tile hadronic calorimeter is a sampling calorimeter using steel as the absorber structure and scintillator as the active medium. The scintillator is located in "pockets" in the steel structure and the wavelength-shifting fibers are contained in channels running radially within the absorber to photomultiplier tubes which are located in the outer support girders of the calorimeter structure. In addition, to its role as a detector for high energy particles, the tile calorimeter provides the direct support of the liquid argon electromagnetic calorimeter in the barrel region, and the liquid argon electromagnetic and hadronic calorimeters in the endcap region. Through these, it indirectly supports the inner tracking system and beam pipe. The steel absorber, and in particular the support girders, provide the flux return for the solenoidal field from the central solenoid. Finally, the end surfaces of the barrel calorimeter are used to mount services, power supplies and readout crates for the inner tr...

  7. Evaluation of various planar gaseous detectors with Cs1 photocathodes for the detection of primary scintillation light from noble gases

    CERN Document Server

    Periale, L; Carlson, Per J; Iacobaeus, C; Francke, T; Pavlopoulos, N; Pietropaoplo, F; Sokolova, T; Picchi, P

    2003-01-01

    Noble gases and liquids are excellent scintillators and this opens a unique opportunity to directly detect the primary scintillation light produced in these media by photons or particles. This signal can be used for several purposes, for example as a start signal for TPCs or for particle's identification. Usually photomultipliers (PMs) are used for the detection of the scintillation light. In our previous work we have demonstrated that costly PMs could be replaced by gaseous detectors with CsI photocathodes. Such detectors have the same quantum efficiency as the best PMs but at the same time are cheap, simple and have high position and time resolutions. The aim of this work is to evaluate various planar type gaseous detectors with CsI photocathodes in order to choose the best one for the detection of the primary scintillation light from noble gases and liquids. (10 refs).

  8. LHCb Upgrade: Scintillating Fibre Tracker

    Science.gov (United States)

    Tobin, Mark

    2016-07-01

    The LHCb detector will be upgraded during the Long Shutdown 2 (LS2) of the LHC in order to cope with higher instantaneous luminosities and to read out the data at 40 MHz using a trigger-less read-out system. All front-end electronics will be replaced and several sub-detectors must be redesigned to cope with higher occupancy. The current tracking detectors downstream of the LHCb dipole magnet will be replaced by the Scintillating Fibre (SciFi) Tracker. The SciFi Tracker will use scintillating fibres read out by Silicon Photomultipliers (SiPMs). State-of-the-art multi-channel SiPM arrays are being developed to read out the fibres and a custom ASIC will be used to digitise the signals from the SiPMs. The evolution of the design since the Technical Design Report in 2014 and the latest R & D results are presented.

  9. A helical scintillating fiber hodoscope

    CERN Document Server

    Altmeier, M; Bisplinghoff, J; Bissel, T; Bollmann, R; Busch, M; Büsser, K; Colberg, T; Demiroers, L; Diehl, O; Dohrmann, F; Engelhardt, H P; Eversheim, P D; Felden, O; Gebel, R; Glende, M; Greiff, J; Gross, A; Gross-Hardt, R; Hinterberger, F; Jahn, R; Jeske, M; Jonas, E; Krause, H; Lahr, U; Langkau, R; Lindemann, T; Lindlein, J; Maier, R; Maschuw, R; Mayer-Kuckuck, T; Meinerzhagen, A; Naehle, O; Pfuff, M; Prasuhn, D; Rohdjess, H; Rosendaal, D; Von Rossen, P; Sanz, B; Schirm, N; Schulz-Rojahn, M; Schwarz, V; Scobel, W; Thomas, S; Trelle, H J; Weise, E; Wellinghausen, A; Wiedmann, W; Woller, K; Ziegler, R

    1999-01-01

    A novel scintillating fiber hodoscope in helically cylindric geometry has been developed for detection of low multiplicity events of fast protons and other light charged particles in the internal target experiment EDDA at the Cooler Synchrotron COSY. The hodoscope consists of 640 scintillating fibers (2.5 mm diameter), arranged in four layers surrounding the COSY beam pipe. The fibers are helically wound in opposing directions and read out individually using 16-channel photomultipliers connected to a modified commercial encoding system. The detector covers an angular range of 9 deg. <= THETA<=72 deg. and 0 deg. <=phi (cursive,open) Greek<=360 deg. in the lab frame. The detector length is 590 mm, the inner diameter 161 mm. Geometry and granularity of the hodoscope afford a position resolution of about 1.3 mm. The detector design took into consideration a maximum of reliability and a minimum of maintenance. An LED array may be used for monitoring purposes. (author)

  10. LHCb Upgrade: Scintillating Fibre Tracker

    Energy Technology Data Exchange (ETDEWEB)

    Tobin, Mark, E-mail: Mark.Tobin@epfl.ch

    2016-07-11

    The LHCb detector will be upgraded during the Long Shutdown 2 (LS2) of the LHC in order to cope with higher instantaneous luminosities and to read out the data at 40 MHz using a trigger-less read-out system. All front-end electronics will be replaced and several sub-detectors must be redesigned to cope with higher occupancy. The current tracking detectors downstream of the LHCb dipole magnet will be replaced by the Scintillating Fibre (SciFi) Tracker. The SciFi Tracker will use scintillating fibres read out by Silicon Photomultipliers (SiPMs). State-of-the-art multi-channel SiPM arrays are being developed to read out the fibres and a custom ASIC will be used to digitise the signals from the SiPMs. The evolution of the design since the Technical Design Report in 2014 and the latest R & D results are presented.

  11. Scintillation Monitoring Using Asymmetry Index

    Science.gov (United States)

    Shaikh, Muhammad Mubasshir; Mahrous, Ayman; Abdallah, Amr; Notarpietro, Riccardo

    Variation in electron density can have significant effect on GNSS signals in terms of propagation delay. Ionospheric scintillation can be caused by rapid change of such delay, specifically, when they last for a longer period of time. Ionospheric irregularities that account for scintillation may vary significantly in spatial range and drift with the background plasma at speeds of 45 to 130 m/sec. These patchy irregularities may occur several times during night, e.g. in equatorial region, with the patches move through the ray paths of the GNSS satellite signals. These irregularities are often characterized as either ‘large scale’ (which can be as large as several hundred km in East-West direction and many times that in the North-South direction) or ‘small scale’ (which can be as small as 1m). These small scale irregularities are regarded as the main cause of scintillation [1,2]. In normal solar activity conditions, the mid-latitude ionosphere is not much disturbed. However, during severe magnetic storms, the aurora oval extends towards the equator and the equator anomaly region may stretched towards poles extending the scintillation phenomena more typically associated with those regions into mid-latitudes. In such stormy conditions, the predicted TEC may deviate largely from the true value of the TEC both at low and mid-latitudes due to which GNSS applications may be strongly degraded. This work is an attempt to analyze ionospheric scintillation (S4 index) using ionospheric asymmetry index [3]. The asymmetry index is based on trans-ionospheric propagation between GPS and LEO satellites in a radio occultation (RO) scenario, using background ionospheric data provided by MIDAS [4]. We attempted to simulate one of the recent geomagnetic storms (NOAA scale G4) occurred over low/mid-latitudes. The storm started on 26 September 2011 at UT 18:00 and lasted until early hours of 27 September 2011. The scintillation data for the storm was taken from an ionospheric

  12. A helical scintillating fiber hodoscope

    Energy Technology Data Exchange (ETDEWEB)

    Altmeier, M.; Bauer, F.; Bisplinghoff, J.; Bissel, T.; Bollmann, R.; Busch, M.; Buesser, K.; Colberg, T.; Demiroers, L.; Diehl, O.; Dohrmann, F.; Engelhardt, H.P.; Eversheim, P.D.; Felden, O.; Gebel, R.; Glende, M.; Greiff, J.; Gross, A.; Gross-Hardt, R.; Hinterberger, F.; Jahn, R.; Jeske, M.; Jonas, E.; Krause, H.; Lahr, U.; Langkau, R.; Lindemann, T.; Lindlein, J.; Maier, R.; Maschuw, R.; Mayer-Kuckuck, T.; Meinerzhagen, A.; Naehle, O.; Pfuff, M.; Prasuhn, D.; Rohdjess, H.; Rosendaal, D.; Rossen, P. von; Sanz, B.; Schirm, N.; Schulz-Rojahn, M.; Schwarz, V.; Scobel, W.; Thomas, S.; Trelle, H.J.; Weise, E.; Wellinghausen, A.; Wiedmann, W.; Woller, K.; Ziegler, R

    1999-07-21

    A novel scintillating fiber hodoscope in helically cylindric geometry has been developed for detection of low multiplicity events of fast protons and other light charged particles in the internal target experiment EDDA at the Cooler Synchrotron COSY. The hodoscope consists of 640 scintillating fibers (2.5 mm diameter), arranged in four layers surrounding the COSY beam pipe. The fibers are helically wound in opposing directions and read out individually using 16-channel photomultipliers connected to a modified commercial encoding system. The detector covers an angular range of 9 deg. {<=}{theta}{<=}72 deg. and 0 deg. {<=}phi (cursive,open) Greek{<=}360 deg. in the lab frame. The detector length is 590 mm, the inner diameter 161 mm. Geometry and granularity of the hodoscope afford a position resolution of about 1.3 mm. The detector design took into consideration a maximum of reliability and a minimum of maintenance. An LED array may be used for monitoring purposes. (author)

  13. Temperature dependence of alpha-induced scintillation in the 1,1,4,4-tetraphenyl-1,3-butadiene wavelength shifter

    CERN Document Server

    Veloce, L M; Di Stefano, P C F; Noble, A J; Boulay, M G; Nadeau, P; Pollmann, T; Clark, M; Piquemal, M; Schreiner, K

    2015-01-01

    Liquid noble gas based particle detectors often use the organic wavelength shifter 1,1,4,4-tetraphenyl-1,3-butadiene (TPB) which shifts UV scintillation light to the visible regime, facilitating its detection, but which also can scintillate on its own. Dark matter searches based on this type of detector commonly rely on pulse-shape discrimination (PSD) for background mitigation. Alpha-induced scintillation therefore represents a possible background source in dark matter searches. The timing characteristics of this scintillation determine whether this background can be mitigated through PSD. We have therefore characterized the pulse shape and light yield of alpha induced TPB scintillation at temperatures ranging from 300 K down to 4 K, with special attention given to liquid noble temperatures. We find that the pulse shapes and light yield depend strongly on temperature. In addition, the significant contribution of long time constants above ~50 K provides an avenue for discrimination between alpha decay events ...

  14. Scintillation in the Circinus Galaxy water megamasers

    CERN Document Server

    McCallum, J N

    2004-01-01

    We present observations of the 22 GHz water vapor megamasers in the Circinus galaxy made with the Tidbinbilla 70m telescope. These observations confirm the rapid variability seen earlier by Greenhill et al (1997). We show that this rapid variability can be explained by interstellar scintillation, based on what is now known of the interstellar scintillation seen in a significant number of flat spectrum AGN. The observed variability cannot be fully described by a simple model of either weak or diffractive scintillation.

  15. General optical scintillation in turbulent atmosphere

    Institute of Scientific and Technical Information of China (English)

    Ruizhong Rao

    2008-01-01

    A general expression of the scintillation index is proposed for optical wave propagating in turbulent atmosphere under arbitrary fluctuation conditions. The expression depends on extreme behaviors of the scintillation indices under both weak and strong fluctuations. The maximum scintillation index in the onset region and the corresponding Rytov index can be evaluated from the general expression. Plane and spherical waves in the cases of zero and non-zero turbulence inner scale are given as examples for illustration of the general behaviors of scintillation indices.

  16. High-symmetry organic scintillator systems

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Patrick L.

    2017-07-18

    An ionizing radiation detector or scintillator system includes a scintillating material comprising an organic crystalline compound selected to generate photons in response to the passage of ionizing radiation. The organic compound has a crystalline symmetry of higher order than monoclinic, for example an orthorhombic, trigonal, tetragonal, hexagonal, or cubic symmetry. A photodetector is optically coupled to the scintillating material, and configured to generate electronic signals having pulse shapes based on the photons generated in the scintillating material. A discriminator is coupled to the photon detector, and configured to discriminate between neutrons and gamma rays in the ionizing radiation based on the pulse shapes of the output signals.

  17. High-symmetry organic scintillator systems

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Patrick L.

    2017-09-05

    An ionizing radiation detector or scintillator system includes a scintillating material comprising an organic crystalline compound selected to generate photons in response to the passage of ionizing radiation. The organic compound has a crystalline symmetry of higher order than monoclinic, for example an orthorhombic, trigonal, tetragonal, hexagonal, or cubic symmetry. A photodetector is optically coupled to the scintillating material, and configured to generate electronic signals having pulse shapes based on the photons generated in the scintillating material. A discriminator is coupled to the photon detector, and configured to discriminate between neutrons and gamma rays in the ionizing radiation based on the pulse shapes of the output signals.

  18. Designing an optimally proportional inorganic scintillator

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Jai, E-mail: jai.singh@cdu.edu.au [School of Engineering and IT, B-Purple-12, Faculty of EHSE, Charles Darwin University, NT 0909 (Australia); Koblov, Alexander [School of Engineering and IT, B-Purple-12, Faculty of EHSE, Charles Darwin University, NT 0909 (Australia)

    2012-09-01

    The nonproportionality observed in the light yield of inorganic scintillators is studied theoretically as a function of the rates of bimolecular and Auger quenching processes occurring within the electron track initiated by a gamma- or X-ray photon incident on a scintillator. Assuming a cylindrical track, the influence of the track radius and concentration of excitations created within the track on the scintillator light yield is also studied. Analysing the calculated light yield a guideline for inventing an optimally proportional scintillator with optimal energy resolution is presented.

  19. Gamma-ray scintillation counter hodoscope for the experiment S140

    CERN Multimedia

    1975-01-01

    The experiment S140 was set-up in the East Hall (beam p14) by the CERN-Munich-Cracow Collaboration to study the production by negative kaons of a neutral meson associated to a Lambda. Here, the liquid hydrogen target (inside the horizontal black tube) is withdrawn from the surrounding cylindrical gamma-ray-measuring scintillation counter hodoscope.

  20. First Demonstration of a Scintillating Xenon Bubble Chamber for Dark Matter and CE$\

    Energy Technology Data Exchange (ETDEWEB)

    Baxter, D. [Fermilab; Chen, C. J. [Northwestern U.; Crisler, M. [PNL, Richland; Cwiok, T. [Northwestern U.; Dahl, C. E. [Fermilab; Grimsted, A. [Evanston Township High School; Gupta, J. [Northwestern U.; Jin, M. [Northwestern U.; Puig, R. [Northwestern U.; Temples, D. [Northwestern U; Zhang, J. [Northwestern U.

    2017-02-28

    A 30-gram xenon bubble chamber, operated at Northwestern University in June and November 2016, has for the first time observed simultaneous bubble nucleation and scintillation by nuclear recoils in liquid xenon. This chamber is instrumented with a CCD camera for near-IR bubble imaging, a solar-blind PMT to detect 175-nm xenon scintillation light, and a piezoelectric acoustic transducer to detect the ultrasonic emission from a growing bubble. The time-of-nucleation determined from the acoustic signal is used to correlate specific scintillation pulses with bubble-nucleating events. The observed single- and multiple-bubble rates when exposed to a $^{252}$Cf neutron source indicate that, for a thermodynamic "Seitz" threshold of 8.3 keV, the minimum nuclear recoil energy required to nucleate a bubble is between 11 and 25 keV. This is consistent with the observed scintillation spectrum for bubble-nucleating events. We see no evidence for bubble nucleation by gamma rays at the thresholds studied, setting a 90% CL upper limit of $6.3\\times10^{-7}$ bubbles per gamma interaction at a 4.2-keV thermodynamic threshold. This indicates stronger gamma discrimination than in CF$_3$I bubble chambers, supporting the hypothesis that scintillation production suppresses bubble nucleation by electron recoils, while nuclear recoils nucleate bubbles as usual. These measurements establish the noble-liquid bubble chamber as a promising new technology for WIMP and CE$\

  1. Energy resolution of CsI(Na) scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Syntfeld-Kazuch, A., E-mail: syntfeld@ipj.gov.p [Andrzej Soltan Institute for Nuclear Studies, PL-05-400 Otwock-Swierk (Poland); Sibczynski, P.; Moszynski, M. [Andrzej Soltan Institute for Nuclear Studies, PL-05-400 Otwock-Swierk (Poland); Gektin, A.V. [Institute for Scintillation Materials, 60 Lenin Ave., 61001 Kharkov (Ukraine); Czarnacki, W.; Grodzicka, M.; Iwanowska, J.; Szawlowski, M.; Szczesniak, T.; Swiderski, L. [Andrzej Soltan Institute for Nuclear Studies, PL-05-400 Otwock-Swierk (Poland)

    2010-03-15

    The presented paper on CsI(Na) scintillators is a continuation of systematical studies of alkali halide crystals exhibiting more than one exponential decay time. The CsI(Na) crystals are known to have short ({approx}550 ns) and long (few microseconds) components in the scintillation pulse. Previous studies showed that integration of slow components of the light pulse improved the light output, non-proportionality and energy resolution of CsI(Tl), NaI(Tl) in lower temperatures and undoped NaI crystal at liquid nitrogen temperature. In this work, an influence of the shaping time in the spectroscopy amplifier on the light output, non-proportional response to {gamma}-rays, and energy resolution of two different size CsI(Na) scintillators is examined. Each crystal was coupled to the Photonis XP5212 PMT with a photocathode blue sensitivity of 12.2 {mu}A/l mF. The data analysis showed improved proportionality of the crystal response, higher number of photoelectrons/MeV-{gamma}, and consequently, a better overall energy resolution obtained for 12 {mu}s shaping time constant. Finally, the CsI(Na) characteristics are compared to that obtained previously for NaI(Tl).

  2. Scalability, scintillation readout and charge drift in a kilogram scale solid xenon particle detector

    CERN Document Server

    Yoo, J; Jaskierny, W F; Markley, D; Pahlka, R B; Balakishiyeva, D; Saab, T; Filipenko, M

    2014-01-01

    We report a demonstration of the scalability of optically transparent xenon in the solid phase for use as a particle detector above a kilogram scale. We employ a liquid nitrogen cooled cryostat combined with a xenon purification and chiller system to measure the scintillation light output and electron drift speed from both the solid and liquid phases of xenon. Scintillation light output from sealed radioactive sources is measured by a set of high quantum efficiency photomultiplier tubes suitable for cryogenic applications. We observed a reduced amount of photons in solid phase compared to that in liquid phase. We used a conventional time projection chamber system to measure the electron drift time in a kilogram of solid xenon and observed faster electron drift speed in the solid phase xenon compared to that in the liquid phase.

  3. Scalability, Scintillation Readout and Charge Drift in a Kilogram Scale Solid Xenon Particle Detector

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, J. [Fermilab; Cease, H. [Fermilab; Jaskierny, W. F. [Fermilab; Markley, D. [Fermilab; Pahlka, R. B. [Fermilab; Balakishiyeva, D. [Florida U.; Saab, T. [Florida U.; Filipenko, M. [Erlangen - Nuremberg U., ECAP

    2014-10-23

    We report a demonstration of the scalability of optically transparent xenon in the solid phase for use as a particle detector above a kilogram scale. We employ a liquid nitrogen cooled cryostat combined with a xenon purification and chiller system to measure the scintillation light output and electron drift speed from both the solid and liquid phases of xenon. Scintillation light output from sealed radioactive sources is measured by a set of high quantum efficiency photomultiplier tubes suitable for cryogenic applications. We observed a reduced amount of photons in solid phase compared to that in liquid phase. We used a conventional time projection chamber system to measure the electron drift time in a kilogram of solid xenon and observed faster electron drift speed in the solid phase xenon compared to that in the liquid phase.

  4. Photodetectors for scintillator proportionality measurement

    Energy Technology Data Exchange (ETDEWEB)

    Moses, William W. [Lawrence Berkeley National Laboratory (United States)], E-mail: wwmoses@lbl.gov; Choong, Woon-Seng [Lawrence Berkeley National Laboratory (United States); Hull, Giulia; Payne, Steve; Cherepy, Nerine; Valentine, John D. [Lawrence Livermore National Laboratory (United States)

    2009-10-21

    We evaluate photodetectors for use in a Compton Coincidence apparatus designed for measuring scintillator proportionality. There are many requirements placed on the photodetector in these systems, including active area, linearity, and the ability to accurately measure low light levels (which implies high quantum efficiency and high signal-to-noise ratio). Through a combination of measurement and Monte Carlo simulation, we evaluate a number of potential photodetectors, especially photomultiplier tubes and hybrid photodetectors. Of these, we find that the most promising devices available are photomultiplier tubes with high ({approx}50%) quantum efficiency, although hybrid photodetectors with high quantum efficiency would be preferable.

  5. Photodetectors for Scintillator Proportionality Measurement

    Energy Technology Data Exchange (ETDEWEB)

    Moses, William W.; Choong, Woon-Seng; Hull, Giulia; Payne, Steve; Cherepy, Nerine; Valentine, J.D.

    2010-10-18

    We evaluate photodetectors for use in a Compton Coincidence apparatus designed for measuring scintillator proportionality. There are many requirements placed on the photodetector in these systems, including active area, linearity, and the ability to accurately measure low light levels (which implies high quantum efficiency and high signal-to-noise ratio). Through a combination of measurement and Monte Carlo simulation, we evaluate a number of potential photodetectors, especially photomultiplier tubes and hybrid photodetectors. Of these, we find that the most promising devices available are photomultiplier tubes with high ({approx}50%) quantum efficiency, although hybrid photodetectors with high quantum efficiency would be preferable.

  6. Performance and characteristics of a new scintillator

    Energy Technology Data Exchange (ETDEWEB)

    Czirr, J.B. [Mission Support Incorporated, Provo, Utah (United States); MacGillivray, G.M. [Nray Services Inc., RP no. 1 Black Bay Road, Petawawa, Ont. K8H2W8 (Canada); MacGillivray, R.R. [Nray Services Inc., RP no. 1 Black Bay Road, Petawawa, Ont. K8H2W8 (Canada); Seddon, P.J. [Nray Services Inc., RP no. 1 Black Bay Road, Petawawa, Ont. K8H2W8 (Canada)

    1999-11-03

    A new class of scintillators for neutron imaging, based upon lithium gadolinium borate, is described. These scintillators offer the ability to tailor their response to the neutron spectrum by varying the relative absorption of neutrons by the key constituents (lithium, gadolinium and boron). The isotopic compositions of each constituent can be varied in order to change the spectral response.

  7. Performance and characteristics of a new scintillator

    CERN Document Server

    Czirr, J B; MacGillivray, R R; Seddon, P J

    1999-01-01

    A new class of scintillators for neutron imaging, based upon lithium gadolinium borate, is described. These scintillators offer the ability to tailor their response to the neutron spectrum by varying the relative absorption of neutrons by the key constituents (lithium, gadolinium and boron). The isotopic compositions of each constituent can be varied in order to change the spectral response.

  8. Mounting LHCb hadron calorimeter scintillating tiles

    CERN Multimedia

    Maximilien Brice

    2004-01-01

    Scintillating tiles are carefully mounted in the hadronic calorimeter for the LHCb detector. These calorimeters measure the energy of particles that interact via the strong force, called hadrons. The detectors are made in a sandwich-like structure where these scintillator tiles are placed between metal sheets.

  9. Application of the efficiency tracing method to the liquid scintillation metrology of 3H and 14C dual-labelled samples; Aplicacion del metodo de la figura de merito a la metrologia por centelleo liquido de muestras doblemente marcadas con 3H y 14C.

    Energy Technology Data Exchange (ETDEWEB)

    Martin-Casallo, M. T.; Los Arcos, J. M.; Grau, A.

    1989-07-01

    Two calculation procedures have been tested for the application of the efficiency tracing method to the activity determination of 3H and 14C dual- -labelled samples in the liquid scintillation metrology. A procedure Ieads to the statement of a linear equations system as a function of the quenching parameter, while the other one uses a least-square algorithm to fit the total count rate against the quenching parameter. The first procedure is strongly sensitive to the statistical uncertainty on the partial efficiencies and produces discrepancies which may reach more than 100% compared to the real values. The second procedure leads to more reliable results, showing discrepancies between 0.1% and 0.6% for the 3H activity and between 0.6% and 5% for the 14C activity, as that the efficiency tracing method can be applied to the metro- logy of dual-labelled samples of 3H and 14C by means of this procedure. (Author) 7 refs.

  10. Prospects of the search for neutrino bursts from Supernovae with Baksan Large Volume Scintillation Detector

    CERN Document Server

    Petkov, V B

    2015-01-01

    Observing a high-statistics neutrino signal from the supernova explosions in the Galaxy is a major goal of low-energy neutrino astronomy. The prospects for detecting all flavors of neutrinos and antineutrinos from the core-collapse supernova (ccSN) in operating and forthcoming large liquid scintillation detectors (LLSD) are widely discussed now. One of proposed LLSD is Baksan Large Volume Scintillation Detector (BLVSD). This detector will be installed at the Baksan Neutrino Observatory (BNO) of the Institute for Nuclear Research, Russian Academy of Sciences, at a depth of 4800 m.w.e. Low-energy neutrino astronomy is one of the main lines of research of the BLVSD.

  11. Development of scintillation materials for PET scanners

    CERN Document Server

    Korzhik, Mikhail; Annenkov, Alexander N; Borissevitch, Andrei; Dossovitski, Alexei; Missevitch, Oleg; Lecoq, Paul

    2007-01-01

    The growing demand on PET methodology for a variety of applications ranging from clinical use to fundamental studies triggers research and development of PET scanners providing better spatial resolution and sensitivity. These efforts are primarily focused on the development of advanced PET detector solutions and on the developments of new scintillation materials as well. However Lu containing scintillation materials introduced in the last century such as LSO, LYSO, LuAP, LuYAP crystals still remain the best PET species in spite of the recent developments of bright, fast but relatively low density lanthanum bromide scintillators. At the same time Lu based materials have several drawbacks which are high temperature of crystallization and relatively high cost compared to alkali-halide scintillation materials. Here we describe recent results in the development of new scintillation materials for PET application.

  12. Inorganic-organic rubbery scintillators

    CERN Document Server

    Gektin, A V; Pogorelova, N; Neicheva, S; Sysoeva, E; Gavrilyuk, V

    2002-01-01

    Spectral-kinetic luminescence properties of films, containing homogeneously dispersed scintillation particles of CsI, CsI:Tl, CsI:Na, and NaI:Tl in optically transparent organosiloxane matrix, are presented. Material is flexible and rubbery and in consequence the detectors of convenient shapes can be produced. It is found that luminescence spectra of the received films are identical whereas decay times are much shorter compared to the same ones of the corresponding single crystals. Layers with pure CsI demonstrate only the fast UV emission (307 nm, 10 ns) without blue microsecond afterglow typical for crystals. The films containing NaI:Tl are non-hygroscopic and preserve scintillation properties for a long time in humid atmosphere unlike single crystals. Organosiloxane layers with CsI:Tl particles provide high light output with good energy resolution for sup 5 sup 5 Fe, sup 1 sup 0 sup 9 Cd, sup 2 sup 4 sup 1 Am sources, and are capable of detecting both X-rays and alpha-, beta-particles.

  13. Theoretical simulation and experimental research of the light output function of liquid scintillator EJ339A%EJ339A型液体闪烁探测系统光输出响应函数的理论模拟与实验研究

    Institute of Scientific and Technical Information of China (English)

    王亭亭; 王亮; 莫钊洪; 赵德山; 熊忠华

    2016-01-01

    对液体闪烁探测器EJ339A中子与伽马辐射测量问题,采用理论模拟与实验分析方法,结合自主设计搭建的基于LabVIEW的数字化信号处理系统,分别完成22Na、133Ba、137Cs和60Co等4种不同能量的γ源等效电子能量测量与刻度。在此基础上,利用中子飞行时间测量原理,在不同时间窗下将锎(252Cf)源近似分化成若干个单能中子源,获得1.9‒7.8 MeV范围内中子在探测器中的光输出响应函数。结果表明,理论模拟与实验测量值在低能段比较吻合,而高能段存在约7.3%的误差。%Background: The light output function is an elementary aspect for neutron spectrometry measured by an organic scintillator to unfold the neutron spectrum from the pulse height distribution.Purpose: This paper aims to investigate the properties of a boron-loaded liquid scintillator EJ339A, using photon sources and neutrons from a 252Cf source.Methods: The light output was defined using Compton electron spectra. Pulse shape discrimination (PSD) and time of flight (TOF) were used to distinguish neutron andg-rays. Combining theoretical modeling and experimental research, four different gamma sources are applied to achieve equivalent calibration of electronic energy, namely22Na,133Ba,137Cs, and60Co, respectively. Accordingly, based on TOF method,252Cf, a spontaneous fission neutron source, is treated as several quasi-monoenergetic neutron sources under different time-windows.Results: The electron light output scale was calibrated by the measured detector response. Neutrons deposit energy in the detector and give a light output function with the neutron energy in the range of 1.9‒7.8MeV.Conclusion: It shows that experimental data of light output function are in good agreement with simulation result in the low energy section, while discrepancies arise in the high energy section.

  14. Determination of light output function and angle dependent correction for a stilbene crystal scintillation neutron spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, W. E-mail: hansen@metrs1.mw.tu-dresden.de; Richter, D

    2002-01-01

    In addition to liquid NE213 scintillators also stilbene solid crystals are applied traditionally for fast neutron spectrometry. A proper evaluation of experimental data provides a precise determination of the nonlinear light output function for the given scintillator/photomultiplier combination, and for stilbene additionally an adequate correction of the anisotropy effect. Calibration experiments with monoenergetic neutrons (1.2, 2.5, 5.0, 13.95, 14.8, 19.0 MeV) and various neutron incidence angles were carried out at the accelerator facility of the PTB Braunschweig for two cylindrical scintillators (diameter 30 mm x 25 mm, diameter 10 mm x 10 mm). An improved analytic light output function as well as an adequate angle dependent correction function were derived.

  15. Measurement of α-particle quenching in LAB based scintillator in independent small-scale experiments

    Energy Technology Data Exchange (ETDEWEB)

    Krosigk, B. von [Technische Universitaet Dresden, Institut fuer Kern- und Teilchenphysik, Dresden (Germany); University of British Columbia, Department of Physics and Astronomy, Vancouver, BC (Canada); Chen, M.; Liu, X.; Wright, A. [Queen' s University, Department of Physics, Engineering Physics and Astronomy, Kingston, ON (Canada); Hans, S. [Brookhaven National Laboratory, Upton, NY (United States); Bronx Community College, Bronx, NY (United States); Junghans, A.R. [Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Koegler, T. [Technische Universitaet Dresden, Institut fuer Kern- und Teilchenphysik, Dresden (Germany); Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Kraus, C. [Queen' s University, Department of Physics, Engineering Physics and Astronomy, Kingston, ON (Canada); Laurentian University, Sudbury, ON (Canada); Kuckert, L. [Technische Universitaet Dresden, Institut fuer Kern- und Teilchenphysik, Dresden (Germany); Karlsruher Institut fuer Technologie, Institut fuer Experimentelle Kernphysik, Karlsruhe (Germany); Nolte, R. [Physikalisch-Technische Bundesanstalt, Braunschweig (Germany); O' Keeffe, H.M. [Queen' s University, Department of Physics, Engineering Physics and Astronomy, Kingston, ON (Canada); Lancaster University, Physics Department, Lancaster (United Kingdom); Tseung, H.W.C. [University of Washington, Department of Physics, Center for Experimental Nuclear Physics and Astrophysics, Seattle, WA (United States); Mayo Clinic, Department of Radiation Oncology, Rochester, MN (United States); Wilson, J.R. [Queen Mary, University of London, School of Physics and Astronomy, London (United Kingdom); Yeh, M. [Brookhaven National Laboratory, Upton, NY (United States); Zuber, K. [Technische Universitaet Dresden, Institut fuer Kern- und Teilchenphysik, Dresden (Germany)

    2016-03-15

    The α-particle light response of liquid scintillators based on linear alkylbenzene (LAB) has been measured with three different experimental approaches. In the first approach, α-particles were produced in the scintillator via {sup 12}C(n,α){sup 9}Be reactions. In the second approach, the scintillator was loaded with 2 % of {sup nat}Sm providing an α-emitter, {sup 147}Sm, as an internal source. In the third approach, a scintillator flask was deployed into the water-filled SNO+ detector and the radioactive contaminants {sup 222}Rn, {sup 218}Po and {sup 214}Po provided the α-particle signal. The behavior of the observed α-particle light outputs are in agreement with each case successfully described by Birks' law. The resulting Birks parameter kB ranges from (0.0066 ± 0.0016) to (0.0076 ± 0.0003) cm/MeV. In the first approach, the α-particle light response was measured simultaneously with the light response of recoil protons produced via neutron- proton elastic scattering. This enabled a first time a direct comparison of kB describing the proton and the α-particle response of LAB based scintillator. The observed kB values describing the two light response functions deviate by more than 5σ. The presented results are valuable for all current and future detectors, using LAB based scintillator as target, since they depend on an accurate knowledge of the scintillator response to different particles. (orig.)

  16. Scintillation Light Detection System in LArIAT

    Energy Technology Data Exchange (ETDEWEB)

    Kryczynski, Pawel [Cracow, INP

    2016-02-29

    The LArIAT experiment is currently taking data at Fermilab using a Liquid Argon TPC, with the aim of studying particle interactions and characterizing detector response for neutrino detectors using argon. In parallel, it serves as a test-bench to develop and evaluate the performance of the simulation, reconstruction, and analysis software used in LAr neutrino experiments. LArIAT also takes advantage of the scintillating capabilities of liquid argon and will evaluate the feasibility of using the light signal to determine calorimetric information and particle identification. To test this possibility, a scintillation light detection system consisting of high Quantum Efficiency (QE) PMT and Silicon Photomultiplier (SiPM) devices is installed in the cryostat, viewing the interior of the TPC. Light collection efficiency is maximized by means of lining the walls with reflector foils covered by a wavelength shifter layer. Collecting the light reflected at the boundaries of the active volume greatly improves also the uniformity of the light yield. Presented here are initial results of the LArIAT light detection system calibration together with the preliminary results of the dedicated simulation and its application in future LAr TPC experiments

  17. Effect of an electric field on superfluid helium scintillation produced by α-particle sources

    Science.gov (United States)

    Ito, T. M.; Clayton, S. M.; Ramsey, J.; Karcz, M.; Liu, C.-Y.; Long, J. C.; Reddy, T. G.; Seidel, G. M.

    2012-04-01

    We report a study of the intensity and time dependence of scintillation produced by weak α-particle sources in superfluid helium in the presence of an electric field (0-45 kV/cm) in the temperature range of 0.2 to 1.1 K at the saturated vapor pressure. Both the prompt and the delayed components of the scintillation exhibit a reduction in intensity with the application of an electric field. The reduction in the intensity of the prompt component is well approximated by a linear dependence on the electric field strength with a reduction of 15% at 45 kV/cm. When analyzed using the Kramers theory of columnar recombination, this electric field dependence leads to the conclusion that roughly 40% of the scintillation results from species formed from atoms originally promoted to excited states and 60% from excimers created by ionization and subsequent recombination with the charges initially having a cylindrical Gaussian distribution about the α track of 60 nm radius. The intensity of the delayed component of the scintillation has a stronger dependence on the electric field strength and on temperature. The implications of these data on the mechanisms affecting scintillation in liquid helium are discussed.

  18. Scintillating track image camera-SCITIC

    CERN Document Server

    Sato, Akira; Ieiri, Masaharu; Iwata, Soma; Kadowaki, Tetsuhito; Kurosawa, Maki; Nagae, Tomohumi; Nakai, Kozi

    2004-01-01

    A new type of track detector, scintillating track image camera (SCITIC) has been developed. Scintillating track images of particles in a scintillator are focused by an optical lens system on a photocathode on image intesifier tube (IIT). The image signals are amplified by an IIT-cascade and stored by a CCD camera. The performance of the detector has been tested with cosmic-ray muons and with pion- and proton-beams from the KEK 12-GeV proton synchrotron. Data of the test experiments have shown promising features of SCITIC as a triggerable track detector with a variety of possibilities. 7 Refs.

  19. Light Pulses to Photomultipliers from Extended Scintillators

    CERN Document Server

    Boemi, D; CERN. Geneva; Costa, S; Insolia, A; Panebianco, S; Potenza, R; Randazzo, N; Reito, S; Romanski, J; Russo, G V; Tuvé, C

    1994-01-01

    Light pulses received by photomultipliers coupled to scintillators are investigated in the cases of long scintillator slats or rods as well as large disc-shaped ones and compared with pulses from point-like scintillators. Results of experimental tests for the disc-shaped configuration performed with the single photon counting technique are presented and compared with numerical calculations. The calculations were done describing light pulse shape by means of a quite new general analytical method based on virtual light paths and images from geometrical optics. The associated electric pulses from the photomultipliers are then discussed and their dependence from source-photocathode distance are put in light.

  20. Testing gravity with pulsar scintillation measurements

    Science.gov (United States)

    Yang, Huan; Nishizawa, Atsushi; Pen, Ue-Li

    2017-04-01

    We propose to use pulsar scintillation measurements to test predictions of alternative theories of gravity. Compared to single-path pulsar timing measurements, the scintillation measurements can achieve an accuracy of one part in a thousand within one wave period, which means picosecond scale resolution in time, due to the effect of multipath interference. Previous scintillation measurements of PSR B 0834 +06 have hours of data acquisition, making this approach sensitive to mHz gravitational waves. Therefore it has unique advantages in measuring the effect of gravity or other mechanisms on light propagation. We illustrate its application in constraining the scalar gravitational-wave background, in which case the sensitivities can be greatly improved with respect to previous limits. We expect much broader applications in testing gravity with existing and future pulsar scintillation observations.

  1. Testing Gravity with Pulsar Scintillation Measurements

    CERN Document Server

    Yang, Huan; Pen, Ue-Li

    2016-01-01

    We propose to use pulsar scintillation measurements to test predictions of alternative theories of gravity. Comparing to single-path pulsar timing measurements, the scintillation measurements can achieve a factor of 10^5 improvement in timing accuracy, due to the effect of multi-path interference. Previous scintillation measurements of PSR B0834+06 have data acquisition for hours, making this approach sensitive to mHz gravitational waves. Therefore it has unique advantages in measuring gravitational effect or other mechanisms (at mHz and above frequencies) on light propagation. We illustrate its application in constraining scalar gravitational-wave background, in which case the sensitivities can be greatly improved with respect to previous limits. We expect much broader applications in testing gravity with existing and future pulsar scintillation observations.

  2. Pulsar Scintillation and the Local Bubble

    CERN Document Server

    Bhat, N D R; Rao, A P; Gupta, Yashwant

    1998-01-01

    We present here the results from an extensive scintillation study of twenty pulsars in the dispersion measure (DM) range 3 - 35 pc cm^-3 caried out using the Ooty Radio Telescope (ORT) at 327 MHz, to investigate the distribution of ionized material in the local interstellar medium. Observations were made during the period January 1993 to August 1995, in which the dynamic scintillation spectra of these pulsars were regularly monitored over 10 - 90 epochs spanning 100 days. Reliable and accurate estimates of strengths of scattering have been deduced from the scintillation parameters averaged out for their long-term fluctuations arising from refractive scintillation (RISS) effects. Our analysis reveals several anomalies in the scattering strength, which suggest tht the distribution of scattering material in the Solar neighborhood is not uniform. We have modelled these anomalous scattering effects in terms of inhomogeneities in the distribution of electron dnsity fluctuations in the local interstellar medium (LIS...

  3. Spectrometric characteristics of polystyrene scintillation films

    CERN Document Server

    Astvatsaturov, A R; Gavalyan, V B; Gavalyan, V G

    1999-01-01

    The spectrometric characteristics of five types of polystyrene scintillation films with thicknesses of 10, 30, 50 and 80 mu m and of analogous 250 mu m thick plates irradiated with sup 2 sup 3 sup 9 Pu, sup 2 sup 3 sup 8 Pu and sup 2 sup 2 sup 6 Ra sources of alpha-particles have been studied. The prospects of utilization of scintillation films as radiators for detection of heavy charged particles and measurement of their energy was experimentally shown.

  4. Multi-GNSS for Ionospheric Scintillation Studies

    Science.gov (United States)

    Morton, Y.

    2015-12-01

    GNSS have been widely used for ionospheric monitoring. We anticipate over 160 GNSS satellites broadcasting 400 signals by 2023, nearly double the number today. With their well-defined signal structures, high spatial density and spectral diversity, GNSS offers low cost and distributed passive sensing of ionosphere effects. There are, however, many challenges to utilize GNSS resources to characterize and forecast ionospheric scintillation. Originally intended for navigation purposes, GNSS receivers are designed to filter out nuisance effects due to ionosphere effects. GNSS measurements are plagued with errors from multipath, oscillator jitters, processing artifacts, and neutral atmosphere effects. Strong scintillation events are often characterized by turbulent structures in ionosphere, causing simultaneous deep amplitude fading and abrupt carrier phase changes. The combined weak signal and high carrier dynamics imposes conflicting requirements for GNSS receiver design. Therefore, GNSS receivers often experience cycle slips and loss of lock of signals during strong scintillation events. High quality, raw GNSS signals bearing space weather signatures and robust receiver algorithms designed to capture these signatures are needed in order for GNSS to be a reliable and useful agent for scintillation monitoring and forecasting. Our event-driven, reconfigurable data collection system is designed to achieve this purpose. To date, our global network has collected ~150TB of raw GNSS data during space weather events. A suite of novel receiver processing algorithms has been developed by exploitating GNSS spatial, frequency, temporal, and constellation diversity to process signals experiencing challenging scintillation impact. The algorithms and data have advanced our understanding of scintillation impact on GNSS, lead to more robust receiver technologies, and enabled high spatial and temporal resolution depiction of ionosphere responses to solar and geomagnetic conditions. This

  5. Ionospheric scintillation effects on single frequency GPS

    Science.gov (United States)

    Steenburgh, R. A.; Smithtro, C. G.; Groves, K. M.

    2008-04-01

    Ionospheric scintillation of Global Positioning System (GPS) signals threatens navigation and military operations by degrading performance or making GPS unavailable. Scintillation is particularly active within, although not limited to, a belt encircling the Earth within 20 degrees of the geomagnetic equator. As GPS applications and users increase, so does the potential for degraded precision and availability from scintillation. We examined amplitude scintillation data spanning 7 years from Ascension Island, U.K.; Ancon, Peru; and Antofagasta, Chile in the Atlantic/American longitudinal sector as well as data from Parepare, Indonesia; Marak Parak, Malaysia; Pontianak, Indonesia; Guam; and Diego Garcia, U.K. in the Pacific longitudinal sector. From these data, we calculate percent probability of occurrence of scintillation at various intensities described by the S4 index. Additionally, we determine Dilution of Precision at 1 min resolution. We examine diurnal, seasonal, and solar cycle characteristics and make spatial comparisons. In general, activity was greatest during the equinoxes and solar maximum, although scintillation at Antofagasta, Chile was higher during 1998 rather than at solar maximum.

  6. Performance of scintillation materials at cryogenic temperatures

    CERN Document Server

    Mikhailik, V B

    2010-01-01

    An increasing number of applications of scintillators at low temperatures, particularly in cryogenic experiments searching for rare events, has motivated the investigation of scintillation properties of materials over a wide temperature range. This paper provides an overview of the latest results on the study of luminescence, absorption and scintillation properties of materials selected for rare event searches so far. These include CaWO4, ZnWO4, CdWO4, MgWO4, CaMoO4, CdMoO4, Bi4Ge3O12, CaF2, MgF2, ZnSe and AL2O3-Ti. We discuss the progress achieved in research and development of these scintillators, both in material preparation and in the understanding of scintillation mechanisms, as well as the underlying physics. To understand the origin of the performance limitation of self-activated scintillators we employed a semi-empirical model of conversion of high energy radiation into light and made appropriate provision for effects of temperature and energy transfer. We conclude that the low-temperature value of th...

  7. Scintillation light, ionization yield and scintillation decay times in high pressure xenon and xenon methane

    NARCIS (Netherlands)

    Pushkin, K. N.; Akimov, D. Y.; Burenkov, A. A.; Dmitrenko, V. V.; Kovalenko, A. G.; Lebedenko, V. N.; Kuznetsov, I. S.; Stekhanov, V. N.; Tezuka, C.; Ulin, S. E.; Uteshev, Z. M.; Vlasik, K. F.

    2007-01-01

    Scintillation light, ionization yield and scintillation decay times have been measured in xenon and in its mixture with a 0.05% concentration of methane as a function of the reduced electric field (E/N)-the ratio of the electric field strength to the number density of gas-at a pressure of 21 atm. Th

  8. Role of hot electron transport in scintillators: A theoretical study

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Huihui [SZU-NUS Collaborative Innovation Center for Optoelectronic Science and Technology, Key Lab. of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Optoelectronic Engineering, Shenzhen Univ. (China); Li, Qi [Physical Sciences Division, IBM TJ Watson Research Center, Yorktown Heights, NY (United States); Department of Computer Science, University of Illinois at Urbana-Champaign, Urbana, IL (United States); Lu, Xinfu; Williams, R.T. [Department of Physics, Wake Forest University, Winston Salem, NC (United States); Qian, Yiyang [College of Engineering and Applied Science, Nanjing University (China); Wu, Yuntao [Scintillation Materials Research Center, University of Tennessee, Knoxville, TN (United States)

    2016-10-15

    Despite recent intensive study on scintillators, several fundamental questions on scintillator properties are still unknown. In this work, we use ab-initio calculations to determine the energy dependent group velocity of the hot electrons from the electronic structures of several typical scintillators. Based on the calculated group velocities and optical phonon frequencies, a Monte-Carlo simulation of hot electron transport in scintillators is carried out to calculate the thermalization time and diffusion range in selected scintillators. Our simulations provide physical insights on a recent trend of improved proportionality and light yield from mixed halide scintillators. (copyright 2016 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  9. Developing LAr Scintillation Light Collection Ideas in the Short Baseline Neutrino Detector

    Energy Technology Data Exchange (ETDEWEB)

    Szelc, A. M. [Manchester U.

    2016-02-08

    Scintillation light is becoming the most rapidly developing feature of Liquid Argon Time Projection Chamber (LArTPC) neutrino detectors due to its capability to enhance and expand their physics reach traditionally based on charge readout. The SBND detector, set to be built on the Booster Neutrino Beam Line at Fermilab, is in a unique position to test novel liquid argon scintillation light readout systems in a detector with physics neutrino events. The different ideas under consideration by the collaboration are described, including an array of PMTs detecting direct light, SiPM coupled lightguide bars and a setup which uses PMTs/SiPMS and wavelength shifter covered reflector foils, as well as their respective strengths and physics foci and the benchmarks used to compare them.

  10. Optimization of detection system based on inorganic scintillation crystal coupled with a long lightguide

    CERN Document Server

    Globus, M; Ratner, M

    2002-01-01

    Operation characteristics of a scintillation crystal, linked with the photomultiplier by a long transparent lightguide, are considered (such detection systems are used for monitoring the seawater pollution, scintillation measurements in magnetic field, etc.). This system is optimized with respect to the refractive index of the liquid, coupling the crystal with the lightguide, and the roughness degree of the crystal surface. It is shown that the energy resolution of the system can be significantly improved by using the coupling liquid with a refractive index somewhat less than that of the lightguide (a difference of about 0.2 is optimal). Light output and especially energy resolution becomes better with an increase of the roughness degree of the reflecting surface.

  11. Mixture quantification using PLS in plastic scintillation measurements

    Energy Technology Data Exchange (ETDEWEB)

    Bagan, H.; Tarancon, A.; Rauret, G. [Departament de Quimica Analitica, Universitat de Barcelona, Diagonal 647, E-08028 Barcelona (Spain); Garcia, J.F., E-mail: jfgarcia@ub.ed [Departament de Quimica Analitica, Universitat de Barcelona, Diagonal 647, E-08028 Barcelona (Spain)

    2011-06-15

    This article reports the capability of plastic scintillation (PS) combined with multivariate calibration (Partial least squares; PLS) to detect and quantify alpha and beta emitters in mixtures. While several attempts have been made with this purpose in mind using liquid scintillation (LS), no attempt was done using PS that has the great advantage of not producing mixed waste after the measurements are performed. Following this objective, ternary mixtures of alpha and beta emitters ({sup 241}Am, {sup 137}Cs and {sup 90}Sr/{sup 90}Y) have been quantified. Procedure optimisation has evaluated the use of the net spectra or the sample spectra, the inclusion of different spectra obtained at different values of the Pulse Shape Analysis parameter and the application of the PLS1 or PLS2 algorithms. The conclusions show that the use of PS+PLS2 applied to the sample spectra, without the use of any pulse shape discrimination, allows quantification of the activities with relative errors less than 10% in most of the cases. This procedure not only allows quantification of mixtures but also reduces measurement time (no blanks are required) and the application of this procedure does not require detectors that include the pulse shape analysis parameter.

  12. Advanced Scintillator Detectors for Neutron Imaging in Inertial Confinement Fusion

    Science.gov (United States)

    Geppert-Kleinrath, Verena; Danly, Christopher; Merrill, Frank; Simpson, Raspberry; Volegov, Petr; Wilde, Carl

    2016-10-01

    The neutron imaging team at Los Alamos National Laboratory (LANL) has been providing two-dimensional neutron imaging of the inertial confinement fusion process at the National Ignition Facility (NIF) for over five years. Neutron imaging is a powerful tool in which position-sensitive detectors register neutrons emitted in the fusion reactions, producing a picture of the burning fuel. Recent images have revealed possible multi-dimensional asymmetries, calling for additional views to facilitate three-dimensional imaging. These will be along shorter lines of sight to stay within the existing facility at NIF. In order to field imaging capabilities equivalent to the existing system several technological challenges have to be met: high spatial resolution, high light output, and fast scintillator response to capture lower-energy neutrons, which have scattered from non-burning regions of fuel. Deuterated scintillators are a promising candidate to achieve the timing and resolution required; a systematic study of deuterated and non-deuterated polystyrene and liquid samples is currently ongoing. A test stand has been implemented to measure the response function, and preliminary data on resolution and light output have been obtained at the LANL Weapons Neutrons Research facility.

  13. The Advanced Scintillator Compton Telescope (ASCOT) balloon project

    Science.gov (United States)

    Bloser, Peter F.; Sharma, Tejaswita; Legere, Jason S.; Bancroft, Christopher M.; McConnell, Mark L.; Ryan, James M.; Wright, Alex M.

    2016-07-01

    We describe a project to develop new medium-energy gamma-ray instrumentation by constructing and flying a balloon-borne Compton telescope using advanced scintillator materials combined with silicon photomultiplier readouts. There is a need in high-energy astronomy for a medium-energy gamma-ray mission covering the energy range from approximately 0.4 - 20 MeV to follow the success of the COMPTEL instrument on CGRO. We believe that directly building on the legacy of COMPTEL, using relatively robust, low-cost, off-the-shelf technologies, is the most promising path for such a mission. Fortunately, high-performance scintillators, such as Lanthanum Bromide (LaBr3), Cerium Bromide (CeBr3), and p-terphenyl, and compact readout devices, such as silicon photomultipliers (SiPMs), are already commercially available and capable of meeting this need. We have conducted two balloon flights of prototype instruments to test these technologies. The first, in 2011, demonstrated that a Compton telescope consisting of an liquid organic scintillator scattering layer and a LaBr3 calorimeter effectively rejects background under balloon-flight conditions, using time-of-flight (ToF) discrimination. The second, in 2014, showed that a telescope using an organic stilbene crystal scattering element and a LaBr3 calorimeter with SiPM readouts can achieve similar ToF performance. We are now constructing a much larger balloon instrument, an Advanced Scintillator Compton Telescope (ASCOT) with SiPM readout, with the goal of imaging the Crab Nebula at MeV energies in a one-day flight. We expect a 4σ detection up to 1 MeV in a single transit. We present calibration results of the first detector modules, and updated simulations of the balloon instrument sensitivity. If successful, this project will demonstrate that the energy, timing, and position resolution of this technology are sufficient to achieve an order of magnitude improvement in sensitivity in the mediumenergy gamma-ray band, were it to be

  14. Semiconductor quantum dot scintillation under gamma-ray irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Letant, S E; Wang, T

    2006-08-23

    We recently demonstrated the ability of semiconductor quantum dots to convert alpha radiation into visible photons. In this letter, we report on the scintillation of quantum dots under gamma-ray irradiation, and compare the energy resolution of the 59 keV line of Americium 241 obtained with our quantum dot-glass nanocomposite material to that of a standard sodium iodide scintillator. A factor 2 improvement is demonstrated experimentally and interpreted theoretically using a combination of energy-loss and photon transport models. These results demonstrate the potential of quantum dots for room-temperature gamma-ray detection, which has applications in medical imaging, environmental monitoring, as well as security and defense. Present technology in gamma radiation detection suffers from flexibility and scalability issues. For example, bulk Germanium provides fine energy resolution (0.2% energy resolution at 1.33 MeV) but requires operation at liquid nitrogen temperature. On the other hand, Cadmium-Zinc-Telluride is a good room temperature detector ( 1% at 662 keV) but the size of the crystals that can be grown is limited to a few centimeters in each direction. Finally, the most commonly used scintillator, Sodium Iodide (NaI), can be grown as large crystals but suffers from a lack of energy resolution (7% energy resolution at 662 keV). Recent advancements in nanotechnology6-10 have provided the possibility of controlling materials synthesis at the molecular level. Both morphology and chemical composition can now be manipulated, leading to radically new material properties due to a combination of quantum confinement and surface to volume ratio effects. One of the main consequences of reducing the size of semiconductors down to nanometer dimensions is to increase the energy band gap, leading to visible luminescence, which suggests that these materials could be used as scintillators. The visible band gap of quantum dots would also ensure both efficient photon counting

  15. Neutron detection by scintillation of noble-gas excimers

    Science.gov (United States)

    McComb, Jacob Collin

    scintillation yields from the 10B( n, alpha)7Li reaction are comparable to the yields of many liquid and solid neutron scintillators. Additionally, the observed slow triplet-state decay of neutron-capture-induced excimers may be used in a practical detector to discriminate neutron interactions from gamma-ray interactions. The results of these measurements and simulations will contribute to the development and optimization of a deployable neutron detector based on noble-gas excimer scintillation.

  16. Scintillation Detectors for Charged Particles and Photons

    CERN Document Server

    Lecoq, P

    2011-01-01

    Scintillation Detectors for Charged Particles and Photons in 'Charged Particle Detectors - Particle Detectors and Detector Systems', part of 'Landolt-Börnstein - Group I Elementary Particles, Nuclei and Atoms: Numerical Data and Functional Relationships in Science and Technology, Volume 21B1: Detectors for Particles and Radiation. Part 1: Principles and Methods'. This document is part of Part 1 'Principles and Methods' of Subvolume B 'Detectors for Particles and Radiation' of Volume 21 'Elementary Particles' of Landolt-Börnstein - Group I 'Elementary Particles, Nuclei and Atoms'. It contains the Subsection '3.1.1 Scintillation Detectors for Charged Particles and Photons' of Section '3.1 Charged Particle Detectors' of Chapter '3 Particle Detectors and Detector Systems' with the content: 3.1.1 Scintillation Detectors for Charged Particles and Photons 3.1.1.1 Basic detector principles and scintillator requirements 3.1.1.1.1 Interaction of ionizing radiation with scintillator material 3.1.1.1.2 Important scint...

  17. Performance of the LAr scintillation veto of Gerda Phase II

    Energy Technology Data Exchange (ETDEWEB)

    Wiesinger, Christoph [Physik-Department and Excellence Cluster Universe, Technische Universitaet Muenchen, James-Franck-Strasse, 85748 Garching (Germany); Collaboration: GERDA-Collaboration

    2016-07-01

    Gerda is an experiment to search for the neutrinoless double beta decay in {sup 76}Ge. Results of Phase I have been published in summer 2013 and Gerda has been upgraded to Phase II. To reach the aspired background index of ∝10{sup -3} cts/(keV.kg.yr) for Phase II active background-suppression techniques are applied, including an active liquid argon (LAr) veto. It has been demonstrated with the LArGe test facility that the detection of argon scintillation light can be used to effectively suppress background events in the germanium detectors, which simultaneously deposit energy in the LAr. The light instrumentation consisting of photomultiplier tubes (PMT) and wavelength-shifting fibers connected to silicon photomultipliers (SiPM) has been installed in Gerda. In this talk the low background design of the LAr veto and its performance during Phase II start-up is reported.

  18. Performance of the LAr scintillation veto of GERDA Phase II

    Energy Technology Data Exchange (ETDEWEB)

    Wiesinger, Christoph [Technische Universitaet Muenchen, Physik Dept. E15, James-Franck-Strasse, 85748 Garching (Germany); Collaboration: GERDA-Collaboration

    2015-07-01

    Gerda is an experiment to search for the neutrinoless double beta decay in {sup 76}Ge. Results of Phase I have been published in summer 2013 and Gerda is upgraded to Phase II. To reach the aspired background index of ≤ 10{sup -3} cts/(keV.kg.yr) for Phase II active background-suppression techniques are applied, including an active liquid argon (LAr) veto. It has been demonstrated with the LArGe test facility that the detection of argon scintillation light can be used to effectively suppress background events in the germanium, which simultaneously deposit energy in the LAr. The light instrumentation consisting of photomultiplier tubes (PMT) and wavelength-shifting fibers connected to silicon multipliers (SiPM) has been installed in Gerda. In this talk the low background design of the LAr veto and its performance during the commissioning runs are reported.

  19. Light yield non-proportionality of undoped YAP scintillator

    Energy Technology Data Exchange (ETDEWEB)

    Klamra, W [Department of Physics, Royal Institute of Technology, 10691 Stockholm (Sweden); Balcerzyk, M; Czarnacki, W; Moszynski, M; Syntfeld-Kazuch, A; Szczesniak, T [Soltan Institute for Nuclear Studies, 05-400 Otwock-Swierk (Poland); Kozlov, V [Lebedev Physical Institute, 117924 Moscow (Russian Federation)], E-mail: klamra@particle.kth.se

    2009-05-15

    Scintillation properties of undoped YAP crystal were studied. The emission spectra show a very intense light component at 360 nm. Analysis of the light pulse shape resulted in five components, four of them, with time constants of 38{+-}2 ns, 92{+-}3 ns, 7.5{+-}0.5 {mu}s and 24{+-}3 {mu}s, representing high light intensity. The light yield was found to be temperature dependent, N{sub ph}= 3090{+-}130 ph/MeV at liquid nitrogen temperature and N{sub ph}= 1440{+-}60 ph/MeV at room temperature. Also the light yield non-proportionality shows temperature dependence and is more pronounced at room temperature.

  20. DESCANT - The DEuterated SCintillator Array for Neutron Tagging

    Science.gov (United States)

    Bildstein, Vinzenz; Garrett, P. E.; Bandyopadhay, D.; Bangay, J.; Bianco, L.; Demand, G.; Hadinia, B.; Leach, K. G.; Sumithrarachchi, C.; Turko, J.; Wong, J.; Ashley, S. F.; Crider, B. P.; McEllistrem, M. T.; Peters, E. E.; Prados-Estévez, F. M.; Yates, S. W.; Vanhoy, J. R.; Ball, G. C.; Bishop, D. P.; Garnsworthy, A. B.; Hackman, G.; Pearson, C. J.; Shaw, B.; Saran, F.

    2016-09-01

    The DESCANT array at TRIUMF is designed to detect neutrons from RIB experiments. DESCANT is composed of 70 close-packed deuterated organic liquid scintillators coupled to digital fast read-out ADC modules. This configuration will permit online pulse-shape discrimination between neutron and γ-ray events. A prototype detector has been tested with monoenergetic neutrons at the accelerator laboratory of the University of Kentucky. A first commissioning experiment of the full array, using the decay of 145-146Cs, will be performed in August 2016. The results of the tests and a preliminary analysis of the commissioning experiment will be presented. Work supported by the Canada Foundation for Innovation, the Natural Sciences and Engineering Research Council of Canada, the National Research Council of Canada and the Canadian Research Chairs program.

  1. Pulse-shape discrimination scintillators for homeland security applications

    Science.gov (United States)

    Ellis, Mark E.; Duroe, Kirk; Kendall, Paul A.

    2016-09-01

    An extensive programme of research has been conducted for scintillation liquids and plastics capable of neutron-gamma discrimination for deployment in future passive and active Homeland Security systems to provide protection against radiological and nuclear threats. The more established detection materials such as EJ-301 and EJ-309 are compared with novel materials such as EJ-299-33 and p-terphenyl. This research also explores the benefits that can be gained from improvements in the analogue-to-digital sampling rate and sample bit resolution. Results are presented on the Pulse Shape Discrimination performance of various detector and data acquisition combinations and how optimum configurations from these studies have been developed into field-ready detector arrays. Early results from application-specific experimental configurations of multi-element detector arrays are presented.

  2. Primary and secondary scintillation measurements in a Xenon Gas Proportional Scintillation Counter

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, L M P; Freitas, E D C; Monteiro, C M B; Santos, J M F dos [Instrumentation Centre, Physics Department, University of Coimbra, P-3004-516 Coimbra (Portugal); Ball, M; Gomez-Cadenas, J J; Yahlali, N [Instituto de Fisica Corpuscular, E-46071, Valencia (Spain); Nygren, D, E-mail: pancho@gian.fis.uc.p [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States)

    2010-09-15

    NEXT is a new experiment to search for neutrinoless double beta decay using a 100 kg radio-pure high-pressure gaseous xenon TPC. The detector requires excellent energy resolution, which can be achieved in a Xe TPC with electroluminescence readout. Hamamatsu R8520-06SEL photomultipliers are good candidates for the scintillation readout. The performance of this photomultiplier, used as VUV photosensor in a gas proportional scintillation counter, was investigated. Initial results for the detection of primary and secondary scintillation produced as a result of the interaction of 5.9 keV X-rays in gaseous xenon, at room temperature and at pressures up to 3 bar, are presented. An energy resolution of 8.0% was obtained for secondary scintillation produced by 5.9 keV X-rays. No significant variation of the primary scintillation was observed for different pressures (1, 2 and 3 bar) and for electric fields up to 0.8 V cm{sup -1} torr{sup -1} in the drift region, demonstrating negligible recombination luminescence. A primary scintillation yield of 81 {+-} 7 photons was obtained for 5.9 keV X-rays, corresponding to a mean energy of 72 {+-} 6 eV to produce a primary scintillation photon in xenon.

  3. Scintillation-Induced Intermittency in SETI

    CERN Document Server

    Cordes, J M; Sagan, Carl Edward; Cordes, James M.; Sagan, Carl

    1997-01-01

    We consider interstellar scintillations as a cause of intermittency in radio signals from extraterrestrial intelligence (ETI). We demonstrate that scintillations are very likely to allow initial detections of narrowband signals from distant sources (> 100 pc), while making redetections improbable. We consider three models in order to assess the non-repeating, narrowband events found in recent SETI and to analyze large surveys in general: (I) Radiometer noise; (II) A population of constant Galactic sources undergoing interstellar scintillation,; and (III) Real, transient signals (or hardware errors) of either terrestrial or ET origin. We apply likelihood and Bayesian tests of the models to The Planetary Society/Harvard META data. We find that Models II and III are both highly preferred to Model I, but that Models II and III are about equally likely. Ruling out Model II in favor of Model III requires many more reobservations than were conducted in META *or* the reobservation threshold must be much lower than wa...

  4. Current trends in scintillator detectors and materials

    CERN Document Server

    Moses, W W

    2002-01-01

    The last decade has seen a renaissance in inorganic scintillator development for gamma ray detection. Lead tungstate (PbWO sub 4) has been developed for high-energy physics experiments, and possesses exceptionally high density and radiation hardness, albeit with low luminous efficiency. Lutetium orthosilicate or LSO (Lu sub 2 SiO sub 5 :Ce) possesses a unique combination of high luminous efficiency, high density, and reasonably short decay time, and is now incorporated in commercial positron emission tomography cameras. There have been advances in understanding the fundamental mechanisms that limit energy resolution, and several recently discovered materials (such as LaBr sub 3 :Ce) possess energy resolution that approaches that of direct solid state detectors. Finally, there are indications that a neglected class of scintillator materials that exhibit near band-edge fluorescence could provide scintillators with sub-nanosecond decay times and high luminescent efficiency.

  5. Characterization of the new scintillator CLYC

    CERN Document Server

    Kui-Nian, Li; Qiang, Gui; Peng, Jin; Geng, Tian

    2016-01-01

    The first domestic inorganic scintillator CLYC was grown in Beijing Glass Research Instituteusing the vertical Bridgman method. In this work, we evaluated the performance of this new CLYC crystal in terms of gamma-ray energy resolution and pulse shape discrimination(PSD)capability between neutrons and gamma-rays. The decay times occurred throughdifferent scintillation mechanisms were achievedby fitting decay functions to the neutron and gamma-ray waveform structures. We found an energy resolution of 4.5% for 662-keV gamma-rays and efficient neutron/gamma PSD withFoM 2.6. Under gamma-ray excitation, there is ultrafast scintillation mechanism in CLYC, with a decay time about 2 ns,whereasthere is no evidence of ultrafast decay under thermal neutron excitation. This work contributes to promote domestic development of CLYC.

  6. Study of nuclear recoils in liquid argon with monoenergetic neutrons

    CERN Document Server

    Regenfus, C; Amsler, C; Creus, W; Ferella, A; Rochet, J; Walter, M

    2012-01-01

    For the development of liquid argon dark matter detectors we assembled a setup in the laboratory to scatter neutrons on a small liquid argon target. The neutrons are produced mono-energetically (E_kin=2.45 MeV) by nuclear fusion in a deuterium plasma and are collimated onto a 3" liquid argon cell operating in single-phase mode (zero electric field). Organic liquid scintillators are used to tag scattered neutrons and to provide a time-of-flight measurement. The setup is designed to study light pulse shapes and scintillation yields from nuclear and electronic recoils as well as from {\\alpha}-particles at working points relevant to dark matter searches. Liquid argon offers the possibility to scrutinise scintillation yields in noble liquids with respect to the populations of the two fundamental excimer states. Here we present experimental methods and first results from recent data towards such studies.

  7. The design of the TASD (totally active scintillator detector) prototype

    Energy Technology Data Exchange (ETDEWEB)

    Mefodiev, A. V., E-mail: Mefodiev@inr.ru; Kudenko, Yu. G. [Moscow Institute of Physics and Technology (State University) (Russian Federation)

    2015-12-15

    Totally active and magnetic segmented scintillation neutrino detectors are developed for the nextgeneration accelerator neutrino experiments. Such detectors will incorporate scintillation modules with scintillation counters that form X and Y planes. A single counter is a 7 × 10 × 90 mm{sup 3} scintillation bar with gluedin wavelength-shifting fibers and micropixel avalanche photodiodes. The results of measurements of the parameters of these detectors are presented.

  8. Combined scintillation detector for gamma dose rate measurement

    Energy Technology Data Exchange (ETDEWEB)

    Viererbl, L.; Novakova, O.; Jursova, L. (Tesla, Premysleni (Czechoslovakia). Vyzkumny Ustav Pristroju Jaderne Techniky)

    1990-01-01

    The specifications are described of a newly developed scintillation detector, essentially consisting of a plastic scintillator completed with inorganic scintillators ZnS(Ag) and NaI(Tl). The gamma dose rate is derived from the photomultiplier anode current. The composition and sizes of the scintillators and the capsule are selected so as to minimise the energy dependence errors and directional dependence errors of the detector response over a wide range of energies and/or angles. (author).

  9. Measurement of $\\alpha$-particle quenching in LAB based scintillator in independent small-scale experiments

    CERN Document Server

    von Krosigk, B; Hans, S; Junghans, A R; Kögler, T; Kraus, C; Kuckert, L; Liu, X; Nolte, R; O'Keeffe, H M; Tseung, H S Wan Chan; Wilson, J R; Wright, A; Yeh, M; Zuber, K

    2015-01-01

    The $\\alpha$-particle light response of liquid scintillators based on linear alkylbenzene (LAB) has been measured with three different experimental approaches. In the first approach, $\\alpha$-particles were produced in the scintillator via $^{12}$C($n$,$\\alpha$)$^9$Be reactions. In the second approach, the scintillator was loaded with 2% of $^{\\mathrm{nat}}$Sm providing an $\\alpha$-emitter, $^{147}$Sm, as an internal source. In the third approach, a scintillator flask was deployed into the water-filled SNO+ detector and the radioactive contaminants $^{222}$Rn, $^{218}$Po and $^{214}$Po provided the $\\alpha$-particle signal. The behavior of the observed $\\alpha$-particle light outputs are in agreement with each case successfully described by Birks' law. The resulting Birks parameter $kB$ ranges from $(0.0071\\pm0.0003)$ cm/MeV to $(0.0076\\pm0.0003)$ cm/MeV. In the first approach, the $\\alpha$-particle light response was measured simultaneously with the light response of recoil protons produced via neutron-proto...

  10. A study on the pulse height resolution of organic scintillator digitized pulses

    Energy Technology Data Exchange (ETDEWEB)

    Belli, Francesco, E-mail: Francesco.Belli@enea.it [Associazione EURATOM-ENEA sulla Fusione, C.R. Frascati, C.P. 65, Frascati I-00044, Rome (Italy); Esposito, Basilio; Marocco, Daniele; Riva, Marco [Associazione EURATOM-ENEA sulla Fusione, C.R. Frascati, C.P. 65, Frascati I-00044, Rome (Italy)

    2013-10-15

    Highlights: ► The frequency analysis of pulses from a liquid scintillator detector is performed. ► The minimum sampling rate required to avoid PH degradation is determined. ► It is shown that interpolation methods increase the FoM for n/γ discrimination. -- Abstract: Organic scintillator detectors are widely used for neutron spectroscopy in fusion devices due to their good energy resolution and capability of neutron/gamma discrimination. Nowadays, scintillator pulses are commonly recorded by means of digital acquisition systems. These have several advantages, and in particular the possibility of off-line data reprocessing: however, the signal digitization can be a cause of degradation of the pulse height (PH) resolution (and therefore of the energy resolution obtained after pulse height spectra unfolding). In this work, the problem of how pulse digitization may influence the pulse height resolution is investigated. First, through downsampling of digitized scintillator pulses, we determine the minimum sampling rate required to avoid any degradation of the pulse height resolution. Secondly, we find that the application of interpolation methods to the digitized pulses does not affect the pulse height resolution, whereas it increases the figure of merit for neutron/gamma discrimination. These results are relevant to define the specifications for the digital acquisition systems of neutron detectors in present and future fusion devices such as JET and ITER.

  11. Light Collection and Pulse-Shape Discrimination in Elongated Scintillator Cells for the PROSPECT Reactor Antineutrino Experiment

    CERN Document Server

    Ashenfelter, J; Band, H R; Barclay, G; Bass, C D; Berish, D; Bowden, N S; Bowes, A; Brodsky, J P; Bryan, C D; Cherwinka, J J; Chu, R; Classen, T; Commeford, K; Davee, D; Dean, D; Deichert, G; Diwan, M V; Dolinski, M J; Dolph, J; Dwyer, D A; Gaison, J K; Galindo-Uribarri, A; Gilje, K; Glenn, A; Goddard, B W; Green, M; Han, K; Hans, S; Heeger, K M; Heffron, B; Jaffe, D E; Langford, T J; Littlejohn, B R; Caicedo, D A Martinez; McKeown, R D; Mendenhall, M P; Mueller, P; Mumm, H P; Napolitano, J; Neilson, R; Norcini, D; Pushin, D; Qian, X; Romero, E; Rosero, R; Saldana, L; Seilhan, B S; Sharma, R; Sheets, S; Stemen, N T; Surukuchi, P T; Varner, R L; Viren, B; Wang, W; White, B; White, C; Wilhelmi, J; Williams, C; Wise, T; Yao, H; Yeh, M; Yen, Y -R; Zangakis, G; Zhang, C; Zhang, X

    2015-01-01

    A meter-long, 23-liter EJ-309 liquid scintillator detector has been constructed to study the light collection and pulse-shape discrimination performance of elongated scintillator cells for the PROSPECT reactor antineutrino experiment. The magnitude and uniformity of light collection and neutron/gamma discrimination power in the energy range of antineutrino inverse beta decay products have been studied using gamma and spontaneous fission calibration sources deployed along the cell long axis. We also study neutron-gamma discrimination and light collection abilities for differing PMT and reflector configurations. Key design features for optimizing MeV-scale response and background rejection capabilities are identified.

  12. Energy transfer and light yield properties of a new highly loaded indium(III) β-diketonate organic scintillator system

    Science.gov (United States)

    Buck, C.; Hartmann, F. X.; Motta, D.; Schoenert, S.

    2007-02-01

    We present combined experimental and model studies of the light yield and energy transfer properties of a newly developed high light yield scintillator based on indium(III)-tris(2,4-pentanedionate) in a 2-(4-biphenyl)-5-phenyloxazole (BPO), methoxybenzene organic liquid; of interest to the detection of solar electron neutrino oscillations. Optical measurements are made to understand the energy transfer properties and a model is advanced to treat the unusual conditions of high metal and fluor loadings. Such scintillator types are of interest to the exploration of novel luminescent materials and the development of large-scale detectors for studying fundamental properties of naturally occurring neutrinos.

  13. Radiation tolerance tests of scintillating fibres

    Energy Technology Data Exchange (ETDEWEB)

    Gavardi, Laura; Albrecht, Johannes [TU Dortmund (Germany); Collaboration: LHCb-Collaboration

    2016-07-01

    An upgrade of the LHCb detector is planned during the shutdown which will take place from mid 2018 to the end of 2019. The proposed upgrade for the tracking system is a detector composed of scintillating fibres read out by silicon photomultipliers. The tracking detector will be working in an environment exposed to radiation, so that the resistance of the fibres to radiation is an important quality, which needs to be investigated. In this talk tests of scintillating fibres tolerance to radiation will be presented.

  14. Recent measurements on scintillator-photodetector systems

    Energy Technology Data Exchange (ETDEWEB)

    Sakai, E.

    1987-02-01

    The pulse height distributions from eleven kinds of scintillators coupled with a photomultiplier (PMT) and with a silicon photodiode were measured for gamma-ray energies between 14 keV and 1836 keV and compared. The numbers of photoelectrons from the PMT photocathode and those of electron-hole pairs in the photodiode were obtained. The intrinsic pulse height broadening was clearly demonstrated in NaI(T1), CsI(Na), CsI(T1) and CsI(pure) scintillators.

  15. International Colloquium on Scattering and Scintillation in Radio Astronomy

    CERN Document Server

    Coles, W A; Rickett, B J; Bird, M K; Efimov, A I; Samoznaev, L N; Rudash, V K; Chashei, I V; Plettemeier, D; Spangler, S R; Tokarev, Y; Belov, Y; Boiko, G; Komrakov, G; Chau, J; Harmon, J; Sulzer, M; Kojima, M; Tokumaru, M; Fujiki, K; Janardhan, P; Jackson, B V; Hick, P P; Buffington, A; Olyak, M R; Fallows, R A; Nechaeva, M B; Gavrilenko, V G; Gorshenkov, Yu N; Alimov, V A; Molotov, I E; Pushkarev, A B; Shanks, R; Tuccari, G; Lotova, N A; Vladimirski, K V; Obridko, V N; Gubenko, V N; Andreev, V E; Stinebring, D R; Gwinn, C; Lovell, J E J; Jauncey, D L; Senkbeil, C; Shabala, S; Bignall, H E; MacQuart, J P; Kedziora-Chudczer, L; Smirnova, T V; Malofeev, V M; Malov, O I; Tyulbashev, S A; Jessner, A; Sieber, W; Wielebinski, R; Scattering and Scintillation in Radio Astronomy

    2006-01-01

    Topics of the Colloquium: a) Interplanetary scintillation b) Interstellar scintillation c) Modeling and physical origin of the interplanetary and the interstellar plasma turbulence d) Scintillation as a tool for investigation of radio sources e) Seeing through interplanetary and interstellar turbulent media Ppt-presentations are available on the Web-site: http://www.prao.ru/conf/Colloquium/main.html

  16. Upconverting nanoparticles for optimizing scintillator based detection systems

    Science.gov (United States)

    Kross, Brian; McKisson, John E; McKisson, John; Weisenberger, Andrew; Xi, Wenze; Zom, Carl

    2013-09-17

    An upconverting device for a scintillation detection system is provided. The detection system comprises a scintillator material, a sensor, a light transmission path between the scintillator material and the sensor, and a plurality of upconverting nanoparticles particles positioned in the light transmission path.

  17. Plastic scintillators modifications for a selective radiation detection

    Energy Technology Data Exchange (ETDEWEB)

    Hamel, Matthieu; Bertrand, Guillaume H.V.; Carrel, Frederick; Coulon, Romain; Dumazert, Jonathan; Montbarbon, Eva; Sguerra, Fabien [CEA, LIST, Laboratoire Capteurs and Architectures electroniques, 91191 Gif-sur-Yvette cedex (France)

    2015-07-01

    Recent developments of plastic scintillators are reviewed, from January 2000 to June 2015. All examples are distributed into the main application, i.e. how the plastic scintillator was modified to enhance the detection towards a given radiation particle. The main characteristics of these newly created scintillators and their detection properties are given. (authors)

  18. 21 CFR 892.1100 - Scintillation (gamma) camera.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Scintillation (gamma) camera. 892.1100 Section 892...) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1100 Scintillation (gamma) camera. (a) Identification. A scintillation (gamma) camera is a device intended to image the distribution of radionuclides...

  19. Establishment of methodology for determination of {sup 93}Zr in radioactive wastes by Liquid Scintillation Counting (LSC) and Inductively Coupled Plasma Mass Spectrometry (ICP-MS); Estabelecimento de metodologia para determinacao de {sup 93}Zr em rejeitos radioativos por Espectrometria de Cintilacao Liquida (LSC) e Espectrometria de Massa com Plasma Indutivamente Acoplado (ICP-MS)

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Thiago Cesar de

    2014-06-01

    The zirconium-93 is a long-lived pure β-particle-emitting radionuclide produced from {sup 235}U fission and from neutron activation of the stable isotope {sup 92}Zr and thus occurring as one of the radionuclides found in nuclear reactors. Due to its long half life, {sup 93}Zr is one of the radionuclides of interest for the performance of assessment studies of waste storage or disposal. Measurement of {sup 93}Zr is difficult owing to its trace level concentration and its low activity in nuclear wastes and further because its certified standards are not frequently available. The aim of this work was to develop a selective radiochemical separation methodology for the determination of {sup 93}Zr in nuclear waste and analyze it by Liquid Scintillation Counting (LSC) and Inductively Coupled Plasma Mass Spectrometry (ICP-MS). To set up the radiochemical separation procedure for zirconium, a tracer solution of {sup 95}Zr and its 724 keV γ-ray measurements by γ- spectrometry were used in order to follow the behavior of zirconium during the radiochemical separation. For the LSC technique a {sup 55}Fe solution, which is one of the major interfering measures zirconium, was used to verify the decontamination factor during the separation process. The efficiency detection for {sup 63}Ni was used to determination of {sup 93}Zr activity in the matrices analyzed. The limit of detection of the 0.05 Bq 1{sup −1} was obtained for {sup 63}Ni standard solutions by using a sample:cocktail ratio of 3:17 mL for Optiphase Hisafe 3 cocktail. For the ICP-MS technique a zirconium stable solution was used to verify the zirconium behavior and recovery during radiochemical separation and a solution of Ba, Co, Eu, Fe, Mn, Nb, Sr and Y was used to verify the decontamination factor during the separation process. A standard solution {sup 93}Nb as isotope for determining the {sup 93}Zr by ICP-MS was used for calibration and analysis. The detection limit of 0.039 ppb was obtained for the standard

  20. Robust GPS carrier tracking under ionospheric scintillation

    Science.gov (United States)

    Susi, M.; Andreotti, M.; Aquino, M. H.; Dodson, A.

    2013-12-01

    Small scale irregularities present in the ionosphere can induce fast and unpredictable fluctuations of Radio Frequency (RF) signal phase and amplitude. This phenomenon, known as scintillation, can degrade the performance of a GPS receiver leading to cycle slips, increasing the tracking error and also producing a complete loss of lock. In the most severe scenarios, if the tracking of multiple satellites links is prevented, outages in the GPS service can also occur. In order to render a GPS receiver more robust under scintillation, particular attention should be dedicated to the design of the carrier tracking stage, that is the receiver's part most sensitive to these types of phenomenon. This paper exploits the reconfigurability and flexibility of a GPS software receiver to develop a tracking algorithm that is more robust under ionospheric scintillation. For this purpose, first of all, the scintillation level is monitored in real time. Indeed the carrier phase and the post correlation terms obtained by the PLL (Phase Locked Loop) are used to estimate phi60 and S4 [1], the scintillation indices traditionally used to quantify the level of phase and amplitude scintillations, as well as p and T, the spectral parameters of the fluctuations PSD. The effectiveness of the scintillation parameter computation is confirmed by comparing the values obtained by the software receiver and the ones provided by a commercial scintillation monitoring, i.e. the Septentrio PolarxS receiver [2]. Then the above scintillation parameters and the signal carrier to noise density are exploited to tune the carrier tracking algorithm. In case of very weak signals the FLL (Frequency Locked Loop) scheme is selected in order to maintain the signal lock. Otherwise an adaptive bandwidth Phase Locked Loop (PLL) scheme is adopted. The optimum bandwidth for the specific scintillation scenario is evaluated in real time by exploiting the Conker formula [1] for the tracking jitter estimation. The performance

  1. Development of scintillator plates with high energy resolution for alpha particles made of GPS scintillator grains

    Science.gov (United States)

    Shimaoka, Takehiro; Kaneko, Junichi H.; Izaki, Kenji; Tsubota, Youichi; Higuchi, Mikio; Nishiyama, Shusuke

    2014-01-01

    A scintillator plate with high energy resolution was developed to produce an alpha particle monitor used in nuclear fuel reprocessing plants and mixed plutonium-uranium oxide (MOX) fuel plants. Grains of a Gd2Si2O7 (GPS) scintillator of several 10 to 550 μm were fixed on a glass substrate and were then mechanically polished. By increasing the size of scintillator grains and removing fine powders, the collected light yield and energy resolution for alpha particles were drastically improved. Energy resolution of 9.3% was achieved using average grain size of 91 μm. Furthermore, the ratios between counts in a peak and total counts were improved by more than 60% by the further increase of grain size and adoption of mechanically polished surfaces on both sides. Beta and gamma ray influences were suppressed sufficiently by the thin 100 μm scintillator plates.

  2. Pulse-shape discrimination of the new plastic scintillators in neutron-gamma mixed field using fast digitizer card

    Science.gov (United States)

    Jančář, A.; Kopecký, Z.; Dressler, J.; Veškrna, M.; Matěj, Z.; Granja, C.; Solar, M.

    2015-11-01

    Recently invented plastic scintillator EJ-299-33 enables pulse-shape discrimination (PSD) and thus measurement of neutron and photon spectra in mixed fields. In this work we compare the PSD properties of EJ-299-33 plastic and the well-known NE-213 liquid scintillator in monoenergetic neutron fields generated by the Van de Graaff accelerator using the 3H(d, n)4He reaction. Pulses from the scintillators are processed by a newly developed digital measuring system employing the fast digitizer card. This card contains two AD converters connected to the measuring computer via 10 Gbps optical ethernet. The converters operate with a resolution of 12 bits and have two differential inputs with a sampling frequency 1 GHz. The resulting digital channels with different gains are merged into one composite channel with a higher digital resolution in a wide dynamic range of energies. Neutron signals are fully discriminated from gamma signals. Results are presented.

  3. Stopping power and mean free path for low-energy electrons in ten scintillators over energy range of 20-20,000 eV.

    Science.gov (United States)

    Tan, Zhenyu; Xia, Yueyuan

    2012-01-01

    Systematic calculations of the stopping powers (SP) and inelastic mean free paths (IMFP) for 20-20,000eV electrons in a group of 10 important scintillators have been carried out. The calculations are based on the dielectric model including the Born-Ochkur exchange correction and the optical energy loss functions (OELFs) are empirically evaluated because of the lack of available experimental optical data for the scintillators under consideration. The evaluated OELFs are examined by both the f-sum rule and the calculation of mean ionization potential. The SP and IMFP data presented here are the first results for the 10 scintillators over the energy range of 20-20,000eV, and are of key importance for the investigation of liquid scintillation counting.

  4. Optimization of Shielded Scintillator for Neutron Detection

    Science.gov (United States)

    Belancourt, Patrick; Morrison, John; Akli, Kramer; Freeman, Richard; High Energy Density Physics Team

    2011-10-01

    The High Energy Density Physics group is interested in the basic science of creating a neutron and gamma ray source. The neutrons and gamma rays are produced by accelerating ions via a laser into a target and creating fusion neutrons and gamma rays. A scintillator and photomultiplier tube will be used to detect these neutrons. Neutrons and photons produce ionizing radiation in the scintillator which then activates metastable states. These metastable states have both short and long decay rates. The initial photon count is orders of magnitude higher than the neutron count and poses problems for accurately detecting the neutrons due to the long decay state that is activated by the photons. The effects of adding lead shielding on the temporal response and signal level of the neutron detector will be studied in an effort to minimize the photon count without significant reduction to the temporal resolution of the detector. MCNP5 will be used to find the temporal response and energy deposition into the scintillator by adding lead shielding. Results from the simulations will be shown. Optimization of our scintillator neutron detection system is needed to resolve the neutron energies and neutron count of a novel neutron and gamma ray source.

  5. Thallium bromide photodetectors for scintillation detection

    CERN Document Server

    Hitomi, K; Shoji, T; Hiratate, Y; Ishibashi, H; Ishii, M

    2000-01-01

    A wide bandgap compound semiconductor, TlBr, has been investigated as a blue sensitive photodetector material for scintillation detection. The TlBr photodetectors have been fabricated from the TlBr crystals grown by the TMZ method using materials purified by many pass zone refining. The performance of the photodetectors has been evaluated by measuring their leakage current, quantum efficiency, spatial uniformity, direct X-ray detection and scintillation detection characteristics. The photodetectors have shown high quantum efficiency for the blue wavelength region and high spatial uniformity for their optical response. In addition, good direct X-ray detection characteristics with an energy resolution of 4.5 keV FWHM for 22 keV X-rays from a sup 1 sup 0 sup 9 Cd radioactive source have been obtained. Detection of blue scintillation from GSO and LSO scintillators irradiated with a sup 2 sup 2 Na radioactive source has been done successfully by using the photodetectors at room temperature. A clear full-energy pea...

  6. Progress in studying scintillator proportionality: Phenomenological model

    Energy Technology Data Exchange (ETDEWEB)

    Bizarri, Gregory; Cherepy, Nerine; Choong, Woon-Seng; Hull, Giulia; Moses, William; Payne, Sephen; Singh, Jai; Valentine, John; Vasilev, Andrey; Williams, Richard

    2009-04-30

    We present a model to describe the origin of non-proportional dependence of scintillator light yield on the energy of an ionizing particle. The non-proportionality is discussed in terms of energy relaxation channels and their linear and non-linear dependences on the deposited energy. In this approach, the scintillation response is described as a function of the deposited energy deposition and the kinetic rates of each relaxation channel. This mathematical framework allows both a qualitative interpretation and a quantitative fitting representation of scintillation non-proportionality response as function of kinetic rates. This method was successfully applied to thallium doped sodium iodide measured with SLYNCI, a new facility using the Compton coincidence technique. Finally, attention is given to the physical meaning of the dominant relaxation channels, and to the potential causes responsible for the scintillation non-proportionality. We find that thallium doped sodium iodide behaves as if non-proportionality is due to competition between radiative recombinations and non-radiative Auger processes.

  7. Light transport in long, plastic scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Gierlik, M. [Soltan Institute for Nuclear Studies, PL 05-400 Swierk-Otwock (Poland)], E-mail: m.gierlik@ipj.gov.pl; Batsch, T.; Marcinkowski, R.; Moszynski, M.; Sworobowicz, T. [Soltan Institute for Nuclear Studies, PL 05-400 Swierk-Otwock (Poland)

    2008-08-11

    As a form of the input into the collaboration the group from the Andrzej Soltan Institute for Nuclear Studies undertook a task of investigating the validity of the design of a compact detector for Gamma Ray Bursts photon polarization measurements, known as POLAR. The authors focused at the scintillation and light transport properties of (200x6x6)mm{sup 3} BC400 plastic bars as well as of other samples of BC408 plastic in the attempt to determine whether the assembled instrument is going to achieve the performance criteria bestowed upon it by the project. The investigation revealed a strong dependence between the amplitude of a signal and distance between the precursor interaction in a scintillator and the photodetector. Accordingly to this finding an attempt has been made to determine the influence of the surface polishing quality on the overall scintillator performance. The authors consider that proper machining of scintillator pieces, adequate choice of their packaging, and proper software analysis may overcome the revealed disadvantages.

  8. Improved light yield of lead tungstate scintillators

    CERN Document Server

    Annenkov, A N; Hofstäetter, A; Korzhik, M V; Ligun, V; Lecoq, P; Missevitch, O V; Novotny, R; Peigneux, J P

    2000-01-01

    The application at medium and low energies of lead tungstate scintillators, so far optimized for the ECAL calorimeter of CMS for the future LHC, is strongly limited by their poor light yield. Suitable dopants like molybdenum and terbium can help to overcome this problem. Concepts, results, advantages and drawbacks of this approach are discussed. (11 refs).

  9. Fluorescent compounds for plastic scintillation applications

    Energy Technology Data Exchange (ETDEWEB)

    Pla-Dalmau, A.; Bross, A.D.

    1994-04-01

    Several 2-(2{prime}-hydroxyphenyl)benzothiazole, -benzoxazole, and -benzimidazole derivatives have been prepared. Transmittance, fluorescence, light yield, and decay time characteristics of these compounds have been studied in a polystyrene matrix and evaluated for use in plastic scintillation detectors. Radiation damage studies utilizing a {sup 60}C source have also been performed.

  10. Scintillation properties of YAG:Yb crystals

    CERN Document Server

    Antonini, P; Carugno, Giovanni; Iannuzzi, D

    2001-01-01

    We report on measurements of the light yield, emission spectrum, and time response of YAG:Yb crystals. The temperature dependence of light yield was investigated. Data show that YAG:Yb crystals are good scintillators, suitable for applications to neutrino detection and spectroscopy.

  11. Development of time-of-flight neutron detector with fast-decay and low-afterglow scintillator for fast ignition experiment

    Directory of Open Access Journals (Sweden)

    Nagai T.

    2013-11-01

    Full Text Available A fast-decay and low-afterglow liquid scintillator was developed for the fast ignition experiment at the Institute of Laser Engineering (ILE. The liquid scintillator was coupled to a gated photomultiplier (PMT, and the gating performance under high-intensity γ-rays was experimentally checked. In 2010, a detector with a high detection efficiency of 10−4 was developed and installed in this experiment. The neutron yield in the fast heating experiment was successfully measured using this detector.

  12. Assessment of scintillation proxy maps for a scintillation study during geomagnetically quiet and disturbed conditions over Uganda

    Science.gov (United States)

    Amabayo, Emirant B.; Jurua, Edward; Cilliers, Pierre J.

    2017-02-01

    The objective of this paper is demonstrate the validity and usefulness of scintillation proxies derived from IGS data, through its comparison with data from dedicated scintillation monitors and its application to GNSS scintillation patterns. The paper presents scintillation patterns developed by using data from the dedicated scintillation monitors of the scintillation network decision aid (SCINDA) network, and proxy maps derived from IGS GPS data for 2011 and 2012 over low latitude stations in Uganda. The amplitude and phase scintillation indicies (S4 and σΦ) were obtained from the Novatel GSV4004B ionospheric scintillation and total electron content (TEC) monitor managed by SCINDA at Makerere (0.340N, 32.570E). The corresponding IGS GPS proxy data were obtained from the receivers at Entebbe (0.040N, 32.440E) and Mbarara (0.600S, 30.740E). The derived amplitude (S4p) and phase (sDPR) scintillation proxy maps were compared with maps of S4 and σΦ during geomagnetic storms (moderate and strong) and geomagnetically quiet conditions. The scintillation patterns using S4 and σΦ and their respective proxies revealed similar diurnal and seasonal patterns of strong scintillation occurrence. The peaks of scintillation occurrence with mean values in the range 0.3 geomagnetically disturbed (moderate and strong) and quiet conditions over the Ugandan region. The results show that SCINDA and IGS based scintillation patterns reveal the same nighttime and seasonal occurrence of irregularities over Uganda irrespective of the geomagnetic conditions. Therefore, the amplitude and phase scintillation proxies presented here can be used to fill gaps in low-latitude data where there are no data available from dedicated scintillation receivers, irrespective of the geomagnetic conditions.

  13. Non-Carbon Dyes For Platic Scintillators- Report

    Energy Technology Data Exchange (ETDEWEB)

    Teprovich, J. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Colon-Mercado, H. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Gaillard, J. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Sexton, L. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Washington, A. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Ward, P. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Velten, J. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-10-19

    Scintillation based detectors are desirable for many radiation detection applications (portal and border monitoring, safeguards verification, contamination detection and monitoring). The development of next generation scintillators will require improved detection sensitivity for weak gamma ray sources, and fast and thermal neutron quantification. Radiation detection of gamma and neutron sources can be accomplished with organic scintillators, however, the single crystals are difficult to grow for large area detectors and subject to cracking. Alternatives to single crystal organic scintillators are plastic scintillators (PS) which offer the ability to be shaped and scaled up to produce large sized detectors. PS is also more robust than the typical organic scintillator and are ideally suited for deployment in harsh real-world environments. PS contain a mixture of dyes to down-convert incident radiation into visible light that can be detected by a PMT. This project will evaluate the potential use of nano-carbon dyes in plastic scintillators.

  14. Scintillation mechanism in stoichiometric cerium compounds

    Energy Technology Data Exchange (ETDEWEB)

    Wojtowicz, A.J.; Lempicki, A.; Berman, E. [Boston Univ., MA (United States). Dept. of Chemistry

    1992-12-31

    These materials constitute a new class of scintillator media, with high speed and high light output. This is illustrated using CeF{sub 3}, and CeP{sub 5}O{sub l4}. While speed, being limited by a radiative lifetime of an allowed d-f transition on the Ce{sup +3} ion, cannot be improved (without loss of the light output), the light output in both cases falls significantly below the estimated theoretical limit. To explain this we propose a mechanism of scintillation process, in which transfer of excitation energy from the lattice to the d-f electronic structure of Ce{sup +3} ions is absent and the light output of the scintillator is limited to the excitation energy directly intercepted by Ce ions. The efficiency depends, therefore, on the competition for holes between Ce{sup +3} ions and anions, determining the share of the total energy deposited by a high energy particle, which can be transformed into scintillation photons. The mechanism requires that the Ce ion has a stable 4+ charge state. Ionization of Ce{sup +3} is followed by capturing of an electron and creation of the Ce bound exciton. In the next step the energy of the bound exciton is transferred to the d-f structure of the Ce ion and, in the final step, a scintillation photon is emitted. The relatively high light output characteristic of these materials is due to the high concentration of Ce ions. The reasons for the lack of efficient energy transfer from the lattice may reside in large relaxation energies of lattice excitations. We use this model to discuss potential improvements in the light output of CeF{sub 3}.

  15. Detection of atmospheric tritium by scintillation. Variations in its concentration in France; Detection du tritium atmospherique par scintillation. Evolution de sa concentration en France

    Energy Technology Data Exchange (ETDEWEB)

    Bibron, R. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-06-01

    The tritium released into the atmosphere as a result of the explosion of thermonuclear devices is a useful radioactive tracer for the study of certain geophysical problems. The low concentrations found however call for the use of extremely sensitive detectors. Two detection methods using liquid scintillators are described. In the first method, the sample is introduced into the scintillator in liquid form, after prior concentration of the tritium by electrolysis. In the second method the tritium is incorporated into the scintillator solvent molecule by chemical synthesis. In the last part of the report are examined the variations in the tritium concentration in rain-water and of the free hydrogen in the air in France. A discussion is then made of the seasonal variations in the case of rain-water and these are compared to the variations in the strontium-90 concentrations. (author) [French] Le tritium introduit dans l'atmosphere par les explosions d'armes thermonucleaires est un traceur radioactif Interessant pour l'etude de certains problemes de geophysique. Les faibles concentrations rencontrees obligent toutefois a utiliser des detecteurs extremement sensibles. On decrit deux methodes de detection utilisant des scintillateurs liquides. Dans la premiere methode, l'echantillon est introduit dans le scintillateur, sous forme aqueuse, apres une concentration prealable du tritium par electrolyse. Dans la seconde methode, le tritium est incorpore a la molecule du solvant du scintillateur par synthese chimique. Dans la derniere partie du rapport, on examine l'evolution de la concentration du tritium dans les eaux de precipitation et l'hydrogene libre de l'air en France. On discute ensuite les variations saisonnieres dans le cas des eaux de precipitation et on les compare aux variations du strontium 90. (auteur)

  16. Construction and Performance of an Iron-Scintillator Hadron Calorimeter with Longitudinal Tile Configuration

    CERN Multimedia

    2002-01-01

    % RD34 \\\\ \\\\ In a scintillator tile calorimeter with wavelength shifting fiber readout significant simplifications of the construction and the assembly are possible if the tiles are oriented $^{\\prime\\prime}$longitudinally$^{\\prime\\prime}$, i.e.~in a r-$\\phi$ planes for a barrel configuration. For a hybrid calorimeter consisting of a scintillator tile hadron compartment and a sufficiently containing liquid argon electromagnetic (EM) compartment, as proposed for the ATLAS detector, good jet resolution is predicted by simulations, which is not affected by this particular orientation of the tiles. \\\\ \\\\The aim of the proposed development program is to construct a calorimeter test module with longitudinal tiles and to check the simulation results by test beam measurements. In addition several component tests and further simulations and engineering studies are needed to optimize the design of a large calorimeter structure to be used in collider experiments. The construction of a test module will also provide valua...

  17. Novel Scintillating Materials Based on Phenyl-Polysiloxane for Neutron Detection and Monitoring

    CERN Document Server

    Degerlier, M; Gramegna, F; Marchi, T; Palma, M Dalla; Cinausero, M; Maggioni, G; Quaranta, A; Collazuol, G; Bermudez, J

    2013-01-01

    Neutron detectors are extensively used at many nuclear research facilities across Europe. Their application range covers many topics in basic and applied nuclear research: in nuclear structure and reaction dynamics (reaction reconstruction and decay studies); in nuclear astrophysics (neutron emission probabilities); in nuclear technology (nuclear data measurements and in-core/off-core monitors); in nuclear medicine (radiation monitors, dosimeters); in materials science (neutron imaging techniques); in homeland security applications (fissile materials investigation and cargo inspection). Liquid scintillators, widely used at present, have however some drawbacks given by toxicity, flammability, volatility and sensitivity to oxygen that limit their duration and quality. Even plastic scintillators are not satisfactory because they have low radiation hardness and low thermal stability. Moreover organic solvents may affect their optical properties due to crazing. In order to overcome these problems, phenyl-polysilox...

  18. Study of Double Strangeness Nuclei by an Emulsion-Scintillating fiber Hybrid Method

    Science.gov (United States)

    Nakazawa, K.

    1995-02-01

    In the emulsion-counter hybrid experiment of KEK-E176, we have analyzed one light double-Λ hypernucleus, at least three heavy double-Λ hypernuclei and two events emitting a sigle-Λ hypernuclei pair found in the sample of ≈80 events of Ξ- capture at rest. Based on this experiment, we have proposed an experiment to study double strangeness nuclei with ten times more events than the E176, ie. 10 3Ξ- stop events. This proposed experiment will clear the uncertainty given by the E176 with use of a new emulsion counter hybrid method, where a laser microscope works for 3D graphic processing in emulsion analysis, scintillating fiber blocks detect decay products of strange particles and a glass capillary tracker filled with liquid scintillator gives precise predictions of Ξ- particle's angle aand position.

  19. Scintillating Cocktail Mixtures and the Role of Water on the Optophysical Properties.

    Energy Technology Data Exchange (ETDEWEB)

    Cordaro, Joseph Gabriel [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Feng, Patrick L. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Mengesha, Wondwosen [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Murtagh, Dustin [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Anstey, Mitchell [Sandia National Lab. (SNL-CA), Livermore, CA (United States)

    2015-10-01

    Two types of water - containing liquid scinti llation mixtures were prepared in the present work. In the first, m ixtures of 2 - phenylethanol, water, diphenyl phosphate, sodium phenyl phosphate dibasic dihydrate, and the dye 2,5 - diphenyloxazole (PPO) have been investigated as liquid scintillators. In th e second system, nonionic and mixed surfactant systems were investigated in conjunction with water and small amounts of toluene. In both cases, increasing amounts of water led to reductions in the scintillation light yield. Understanding what factors contr ibute to this phenomenon is the focus of this report. Changes in the solution microphase structure, diminishing aromatic content of the cocktail mixtures, and inefficient energy transfer to the dye a ppear to be responsible for the decreased light yield as more water is added . In the 2 - phenylethanol system, the observed experimental results are consistent with the formation of a bicontinuous microemulsion at higher water concentrations, which incorporates PPO and shields it from the quenching effects of the increasing polar matrix. Evidence for this proposed phase chan ge c ome s from light scattering data, photo - and x - ray luminescence measurements, and optical transparency measurements . In the surfactant - based system, the quenching effect of water was found to be less than both commercially - available dioxane - naphthalene mixtures used for scintillation counting as well as the 2 - phenylethanol mixtures described above. The effect of different surfactant mixtures and concentrations were studied, revealing a benefic ial effect upon the scintillation light yield for mixed surfactant mixtures. These results are interpreted in the context of r eactive radical species formation following water ionization , which leads to light - yield quenching in aqueous systems . The presenc e of surfactant(s) in these mixtures enables the formation of organic - rich regions that are spatially separated from the

  20. Nonproportionality of Scintillator Detectors: Theory and Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Payne, Stephen; Cherepy, Nerine; Hull, Giulia; Valentine, John; Moses, William; Choong, Woon-Seng

    2009-08-17

    On the basis of nonproportionality data obtained for several scintillators, we have developed a theory to describe the carrier dynamics to fit the light yield versus electron energy. The theory of Onsager was adapted to explain how the carriers form excitons or sequentially arrive at the activators to promote the ion to an excited state, and the theory of Birks was employed to allow for exciton-exciton annihilation. We then developed a second theory to deduce the degradation in resolution that results from nonproportionality by evoking Landau fluctuations, which are essentially variations in the deposited energy density that occur as the high energy electron travels along its trajectory. In general there is good agreement with the data, in terms of fitting the nonproportionality curves and reproducing the literature values of nonproportionality's contribution to the scintillator resolution. With the resurgence of interest in developing scintillator detectors that have good energy resolution, an improved understanding of nonproportionality has become a crucial matter since it presents the fundamental limit to the achievable resolution. In order to hasten an improved understanding of scintillator nonproportionality, we have constructed an instrument referred to as SLYNCI (Scintillator Light Yield Nonproportionality Compton Instrument). This is a second-generation instrument to the original device developed by Valentine and coworkers, wherein several new principles of operation have served to increase the data rate by an order of magnitude as discussed in detail in References. In the present article, the focus is on a theory to describe the measured electron response, which is the light yield as a function of the electron energy. To do this, we account for transport of carriers and excitons, in terms of how they transfer their energy to the activators with competition from nonradiative decay pathways. This work builds on the original work of Murray and coworkers

  1. Measurement of the attenuation length of argon scintillation light in the ArDM LAr TPC

    CERN Document Server

    Calvo, J; Crivelli, P; Daniel, M; DiLuise, S; Gendotti, A; Horikawa, S; Molina-Bueno, L; Montes, B; Mu, W; Murphy, S; Natterer, G; Ngyuen, K; Periale, L; Quan, Y; Radics, B; Regenfus, C; Romero, L; Rubbia, A; Santorelli, R; Sergiampietri, F; Viant, T; Wu, S

    2016-01-01

    We report on a measurement of the attenuation length for the scintillation light in the tonne size liquid argon target of the ArDM dark matter experiment. The data was recorded in the first underground operation of the experiment in single-phase operational mode. The results were achieved by comparing the light yield spectra from 39-Ar and 83m-Kr to a description of the ArDM setup with a model of full light ray tracing. A relatively low value close to 0.5 m was found for the attenuation length of the liquid argon bulk to its own scintillation light. We interpret this result as a presence of optically active impurities in the liquid argon which are not filtered by the installed purification systems. We also present analyses of the argon gas employed for the filling and discuss cross sections in the vacuum ultraviolet of various molecules in respect to purity requirements in the context of large liquid argon installations.

  2. Primary and secondary scintillation measurements in a xenon Gas Proportional Scintillation Counter

    CERN Document Server

    Fernandes, L M P; Ball, M; Gómez-Cadenas, J J; Monteiro, C M B; Yahlali, N; Nygren, D; Santos, J M F dos

    2010-01-01

    NEXT is a new experiment to search for neutrinoless double beta decay using a 100 kg radio-pure high-pressure gaseous xenon TPC. The detector requires excellent energy resolution, which can be achieved in a Xe TPC with electroluminescence readout. Hamamatsu R8520-06SEL photomultipliers are good candidates for the scintillation readout. The performance of this photomultiplier, used as VUV photosensor in a gas proportional scintillation counter, was investigated. Initial results for the detection of primary and secondary scintillation produced as a result of the interaction of 5.9 keV X-rays in gaseous xenon, at room temperature and at pressures up to 3 bar, are presented. An energy resolution of 8.0% was obtained for secondary scintillation produced by 5.9 keV X-rays. No significant variation of the primary scintillation was observed for different pressures (1, 2 and 3 bar) and for electric fields up to 0.8 V cm-1 torr-1 in the drift region, demonstrating negligible recombination luminescence. A primary scinti...

  3. Plastic fiber scintillator response to fast neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Danly, C. R.; Sjue, S.; Wilde, C. H.; Merrill, F. E.; Haight, R. C. [Los Alamos National Laboratory, Los Alamos, New Mexico 87544 (United States)

    2014-11-15

    The Neutron Imaging System at NIF uses an array of plastic scintillator fibers in conjunction with a time-gated imaging system to form an image of the neutron emission from the imploded capsule. By gating on neutrons that have scattered from the 14.1 MeV DT energy to lower energy ranges, an image of the dense, cold fuel around the hotspot is also obtained. An unmoderated spallation neutron beamline at the Weapons Neutron Research facility at Los Alamos was used in conjunction with a time-gated imaging system to measure the yield of a scintillating fiber array over several energy bands ranging from 1 to 15 MeV. The results and comparison to simulation are presented.

  4. Scintillation detectors of Alborz-I experiment

    Energy Technology Data Exchange (ETDEWEB)

    Pezeshkian, Yousef [Department of Physics, Sharif University of Technology, P.O.Box 11155-9161, Tehran (Iran, Islamic Republic of); Alborz Observatory, Sharif University of Technology, P.O.Box 11155-9161, Tehran (Iran, Islamic Republic of); Bahmanabadi, Mahmud, E-mail: bahmanabadi@sharif.edu [Department of Physics, Sharif University of Technology, P.O.Box 11155-9161, Tehran (Iran, Islamic Republic of); Alborz Observatory, Sharif University of Technology, P.O.Box 11155-9161, Tehran (Iran, Islamic Republic of); Abbasian Motlagh, Mehdi; Rezaie, Masume [Alborz Observatory, Sharif University of Technology, P.O.Box 11155-9161, Tehran (Iran, Islamic Republic of)

    2015-02-11

    A new air shower experiment of the Alborz Observatory, Alborz-I, located at the Sharif University of Technology, Iran, will be constructed in near future. An area of about 30×40 m{sup 2} will be covered by 20 plastic scintillation detectors (each with an area of 50×50 cm{sup 2}). A series of experiments have been performed to optimize the height of light enclosures of the detectors for this array and the results have been compared to an extended code simulation of these detectors. Operational parameters of the detector obtained by this code are cross checked by the Geant4 simulation. There is a good agreement between the extended-code and Geant4 simulations. We also present further discussions on the detector characteristics, which can be applicable for all scintillation detectors with a similar configuration.

  5. Semiconductor High-Energy Radiation Scintillation Detector

    CERN Document Server

    Kastalsky, A; Spivak, B

    2006-01-01

    We propose a new scintillation-type detector in which high-energy radiation produces electron-hole pairs in a direct-gap semiconductor material that subsequently recombine producing infrared light to be registered by a photo-detector. The key issue is how to make the semiconductor essentially transparent to its own infrared light, so that photons generated deep inside the semiconductor could reach its surface without tangible attenuation. We discuss two ways to accomplish this, one based on doping the semiconductor with shallow impurities of one polarity type, preferably donors, the other by heterostructure bandgap engineering. The proposed semiconductor scintillator combines the best properties of currently existing radiation detectors and can be used for both simple radiation monitoring, like a Geiger counter, and for high-resolution spectrography of the high-energy radiation. The most important advantage of the proposed detector is its fast response time, about 1 ns, essentially limited only by the recombi...

  6. Ultra-fast timing with plastic scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Hoischen, Robert [Department of Physics, Lund University, S-22100 Lund (Sweden); Helmholtzzentrum fuer Schwerionenforschung GmbH, D-64291 Darmstadt (Germany); Pietri, Stephane; Prokopowicz, Wawrzyniec; Schaffner, Henning; Gerl, Juergen; Wollersheim, Hans Juergen; Kurz, Nikolaus [Helmholtzzentrum fuer Schwerionenforschung GmbH, D-64291 Darmstadt (Germany); Rudolph, Dirk [Department of Physics, Lund University, S-22100 Lund (Sweden)

    2009-07-01

    Fast timing detectors for time-of-flight measurements are essential identification tools for isotopes studied at fragment separators at major heavy-ion research facilities. While today's standard technique of utilizing a plastic scintillator read out by few photomultiplier tubes proofs to be efficient, it does not provide the required time resolution for future key experiments at, for example, the Super-FRS at FAIR. A common present-day approach is to use diamond detectors instead. While they do provide a better time resolution compared to scintillators, they are more difficult to use and far more expensive. Results from tests using a new design approach with standard materials will be presented. This leads to a much improved performance, but remains both cost-efficient, compact, and reliable. The design goals and how to accomplish them will be exemplified by the LYCCA (Lund-York-Cologne CAlorimeter) detector aiming for fast-beam experiments at HISPEC within NUSTAR.

  7. Effect of shallow traps on scintillation

    Energy Technology Data Exchange (ETDEWEB)

    Lempicki, A. [Department of Chemistry, Metcalf Ctr Science and Engineering, 590 Commonwealth Avenue, Boston University, Boston, MA (United States); Bartram, R.H. [Department of Physics, University of Connecticut, Storrs, CT (United States)

    1999-01-04

    The paper establishes the mathematical connection between the process of scintillation in Ce-doped materials and their thermoluminescence. A set of kinetic equations describes the competing processes of radiative recombination and trapping by a single trap. The more general case of second-order kinetics is simplified to first order, allowing an analytic solution. Second-order kinetics is also solved numerically without such simplification and both are successfully applied to explain the temperature dependence of the scintillation light output on temperature, in the range where glow peaks occur. The order of the kinetics predicts rather different shapes of decay, but are difficult to distinguish experimentally. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)

  8. Scintillating 99Tc Selective Ion Exchange Resins

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell Greenhalgh; Richard D. Tillotson

    2012-07-01

    Scintillating technetium (99Tc) selective ion exchange resins have been developed and evaluated for equilibrium capacities and detection efficiencies. These resins can be utilized for the in-situ concentration and detection of low levels of pertechnetate anions (99TcO4-) in natural waters. Three different polystyrene type resin support materials were impregnated with varying amounts of tricaprylmethylammonium chloride (Aliquat 336) extractant, several different scintillating fluors and wavelength shifters. The prepared resins were contacted batch-wise to equilibrium over a wide range of 99TcO4- concentrations in natural water. The measured capacities were used to develop Langmuir adsorption isotherms for each resin. 99Tc detection efficiencies were determined and up to 71.4 ± 2.6% was achieved with some resins. The results demonstrate that a low level detection limit for 99TcO4- in natural waters can be realized.

  9. Central Tracking Detector Based on Scintillating Fibres

    CERN Multimedia

    2002-01-01

    Scintillating fibres form a reasonable compromise for central tracking detectors in terms of price, resolution, response time, occupancy and heat production. \\\\ \\\\ New fluorescents with large Stokes shifts have been produced, capable of working without wavelength shifters. Coherent multibundles have been developed to achieve high packing fractions. Small segments of tracker shell have been assembled and beam tests have confirmed expectations on spatial resolution. An opto-electronic delay line has been designed to delay the track patterns and enable coincidences with a first level trigger. Replacement of the conventional phosphor screen anode with a Si pixel chip is achieved. This tube is called ISPA-tube and has already been operated in beam tests with a scintillating fibres tracker. \\\\ \\\\ The aim of the proposal is to improve hit densities for small diameter fibres by increasing the fraction of trapped light, by reducing absorption and reflection losses, by reflecting light at the free fibre end, and by inc...

  10. Scintillation detectors of Alborz-I experiment

    CERN Document Server

    Pezeshkian, Yousef; Motlagh, Mehdi Abbasian; Rezaie, Masoume

    2014-01-01

    A new air shower experiment of the Alborz Observatory, Alborz-I, located at the Sharif University of Technology, Iran, will be constructed in near future. An area of about 30$\\times$40 m$^{2}$ will be covered by 20 plastic scintillation detectors (each with an area of 50$\\times$50 cm$^{2}$). A series of experiments have been performed to optimize the height of light enclosures of the detectors for this array and the results have been compared to an extended code simulation of these detectors. Operational parameters of the detector obtained by this code are cross checked by Geant4 simulation. There is a good agreement between extended-code and Geant4 simulations. We also present further discussions on the detector characteristics, which can be applicable for all scintillation detectors with a similar configuration.

  11. Transparent Ceramic Scintillator Fabrication, Properties and Applications

    Energy Technology Data Exchange (ETDEWEB)

    Cherepy, N J; Kuntz, J D; Roberts, J J; Hurst, T A; Drury, O B; Sanner, R D; Tillotson, T M; Payne, S A

    2008-08-24

    Transparent ceramics offer an alternative to single crystals for scintillator applications such as gamma ray spectroscopy and radiography. We have developed a versatile, scaleable fabrication method, using Flame Spray Pyrolysis (FSP) to produce feedstock which is readily converted into phase-pure transparent ceramics. We measure integral light yields in excess of 80,000 Ph/MeV with Cerium-doped Garnets, and excellent optical quality. Avalanche photodiode readout of Garnets provides resolution near 6%. For radiography applications, Lutetium Oxide offers a high performance metric and is formable by ceramics processing. Scatter in transparent ceramics due to secondary phases is the principal limitation to optical quality, and afterglow issues that affect the scintillation performance are presently being addressed.

  12. Nanophosphor composite scintillators comprising a polymer matrix

    Science.gov (United States)

    Muenchausen, Ross Edward; Mckigney, Edward Allen; Gilbertson, Robert David

    2010-11-16

    An improved nanophosphor composite comprises surface modified nanophosphor particles in a solid matrix. The nanophosphor particle surface is modified with an organic ligand, or by covalently bonding a polymeric or polymeric precursor material. The surface modified nanophosphor particle is essentially charge neutral, thereby preventing agglomeration of the nanophosphor particles during formation of the composite material. The improved nanophosphor composite may be used in any conventional scintillator application, including in a radiation detector.

  13. Sorohalide scintillators, phosphors, and uses thereof

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Pin; Deng, Haoran; Doty, F. Patrick; Zhou, Xiaowang

    2016-05-10

    The present invention relates to sorohalide compounds having formula A.sub.3B.sub.2X.sub.9, where A is an alkali metal, B is a rare earth metal, and X is a halogen. Optionally, the sorohalide includes a dopant D. Such undoped and doped sorohalides are useful as scintillation materials or phosphors for any number of uses, including for radiation detectors, solid-state light sources, gamma-ray spectroscopy, medical imaging, and drilling applications.

  14. Simulating Silicon Photomultiplier Response to Scintillation Light

    Science.gov (United States)

    Jha, Abhinav K.; van Dam, Herman T.; Kupinski, Matthew A.; Clarkson, Eric

    2015-01-01

    The response of a Silicon Photomultiplier (SiPM) to optical signals is affected by many factors including photon-detection efficiency, recovery time, gain, optical crosstalk, afterpulsing, dark count, and detector dead time. Many of these parameters vary with overvoltage and temperature. When used to detect scintillation light, there is a complicated non-linear relationship between the incident light and the response of the SiPM. In this paper, we propose a combined discrete-time discrete-event Monte Carlo (MC) model to simulate SiPM response to scintillation light pulses. Our MC model accounts for all relevant aspects of the SiPM response, some of which were not accounted for in the previous models. We also derive and validate analytic expressions for the single-photoelectron response of the SiPM and the voltage drop across the quenching resistance in the SiPM microcell. These analytic expressions consider the effect of all the circuit elements in the SiPM and accurately simulate the time-variation in overvoltage across the microcells of the SiPM. Consequently, our MC model is able to incorporate the variation of the different SiPM parameters with varying overvoltage. The MC model is compared with measurements on SiPM-based scintillation detectors and with some cases for which the response is known a priori. The model is also used to study the variation in SiPM behavior with SiPM-circuit parameter variations and to predict the response of a SiPM-based detector to various scintillators. PMID:26236040

  15. Scintillation Detectors in Experiments on Plasma Accelerators

    CERN Document Server

    Bystritsky, V M; Gerasimov, V V; Kublikov, R V; Nechaev, B A; Padalko, V M; Parzhitski, S S; Smirnov, V S; Wozniak, J

    2005-01-01

    The gating circuits for photomultipliers of scintillation detectors operating in powerful pulsed electromagnetic and nuclear radiation fields are investigated. PMTs with the jalousie-type dynode system and with the linear dynode system are considered. The basic gating circuits of the photomultipliers involving active and resistor high-voltage dividers are given. The results of the investigations are important for experiments in which it is necessary to discriminate in time the preceding background radiation and the process of interest.

  16. Improved Neutron Scintillators Based on Nanomaterials

    Energy Technology Data Exchange (ETDEWEB)

    Dennis Friesel, PhD

    2008-06-30

    The development work conducted in this SBIR has so far not supported the premise that using nano-particles in LiFZnS:Ag foils improves their transparency to 420 (or other frequency) light. This conclusion is based solely on the light absorption properties of LiFZnS foils fabricated from nano- and from micro-particles. Furthermore, even for the case of the Gd{sub 2}O{sub 3} foils, the transmission of 420 nm light gained by using nano-particles all but disappears as the foil thickness is increased beyond about 0.2 mm, a practical scintillator thickness. This was not immediately apparent from the preliminary study since no foils thicker than about 0.04 mm were produced. Initially it was believed that the failure to see an improvement by using nano-particles for the LiFZnS foils was caused by the clumping of the particles in Toluene due to the polarity of the ZnS particles. However, we found, much to our surprise, that nano-particle ZnS alone in polystyrene, and in Epoxy, had worse light transmission properties than the micro-particle foils for equivalent thickness and density foils. The neutron detection measurements, while disappointing, are attributable to our inability to procure or fabricate Bulk Doped ZnS nanoparticles. The cause for the failure of nano-particles to improve the scintillation light, and hence improved neutron detection efficiency, is a fundamental one of light scattering within the scintillator. A consequence of PartTec's documentation of this is that several concepts for the fabrication of improved {sup 6}LiFZnS scintillators were formulated that will be the subject of a future SBIR submission.

  17. Wimp Detection Using Liquid Xenon (dark Matter)

    CERN Document Server

    Wang, H

    1998-01-01

    The missing mass "Dark Matter" problem of the Universe is one of the most important questions facing the moden physics and astronomy. This thesis work developed the Liquid Xenon technology to detect the SUSY ark matter. The background rejection principle was tested and many technical problem are studied, including the purification of the liquid xenon to yield both long electron lifetime and long xenon scintillation light attenuation length, and xenon recoil scintillation efficiency measurement. The detector design and construction are studied. Finally a two phase xenon detector was realized for the future dark matter experiment. The key working principle is the use of proportional scintillation and electro-luminescence to detector the ionization components, which is different between background and recoil signals. The two phase test results shown that a detector energy threshold as low as 10keV can be achieved.

  18. Scintillation counter with MRS APD light readout

    CERN Document Server

    INSPIRE-00061314; Malkevich, D.; Martemyanov, A.; Ryabinin, M.; Smirnitsky, A.; Voloshin, K.; Bondarenko, G.; Golovin, V.; Grigoriev, E.

    2005-01-01

    START, a high-efficiency and low-noise scintillation detector for ionizing particles, was developed for the purpose of creating a high-granular system for triggering cosmic muons. Scintillation light in START is detected by MRS APDs (Avalanche Photo-Diodes with Metal-Resistance-Semiconductor structure), operated in the Geiger mode, which have 1 mm^2 sensitive areas. START is assembled from a 15 x 15 x 1 cm^3 scintillating plastic plate, two MRS APDs and two pieces of wavelength-shifting optical fiber stacked in circular coils inside the plastic. The front-end electronic card is mounted directly on the detector. Tests with START have confirmed its operational consistency, over 99% efficiency of MIP registration and good homogeneity. START demonstrates a low intrinsic noise of about 10^{-2} Hz. If these detectors are to be mass-produced, the cost of a mosaic array of STARTs is estimated at a moderate level of 2-3 kUSD/m^2.

  19. A large Scintillating Fibre Tracker for LHCb

    Science.gov (United States)

    Greim, R.

    2017-02-01

    The LHCb experiment will be upgraded during LHC Long Shutdown 2 to be able to record data at a higher instantaneous luminosity. The readout rate is currently limited to 1 MHz by the Level 1 trigger. In order to achieve the target integrated luminosity of 50 fb-1 during LHC Run 3, all subdetectors have to be read out by a 40 MHz trigger-less readout system. Especially, the current tracking detectors downstream of the LHCb dipole magnet suffer from large detector dead times and a small granularity in the Outer Tracker, which consists of proportional straw tubes. Therefore, the Downstream Tracker will be replaced by a Scintillating Fibre Tracker with Silicon Photomultiplier readout. The total sensitive area of 340 m2 is made up of 2.5 m long fibre mats consisting of six staggered layers of 250 μm thin scintillating fibres. The scintillation light created by the charged particles traversing the fibre mats is transported to the fibre ends via total internal reflection and detected by state-of-the-art multi-channel SiPM arrays. This paper presents the detector concept, design, challenges, custom-made readout chips, as well as laboratory and beam test results.

  20. New scintillating crystals for PET scanners

    CERN Document Server

    Lecoq, P

    2002-01-01

    Systematic R&D on basic mechanism in inorganic scintillators, initiated by the Crystal Clear Collaboration at CERN 10 years ago, has contributed not to a small amount, to the development of new materials for a new generation of medical imaging devices with increased resolution and sensitivity. The first important requirement for a scintillator to be used in medical imaging devices is the stopping power for the given energy range of X and gamma rays to be considered, and more precisely the conversion efficiency. A high light yield is also mandatory to improve the energy resolution, which is essentially limited by the photostatistics and the electronic noise at these energies. A short scintillation decay time allows to reduce the dead time and therefore to increase the limiting counting rate. When all these requirements are fulfilled the sensitivity and image contrast are increased for a given patient dose, or the dose can be reduced. Examples of new materials under development by the Crystal Clear Collabor...