WorldWideScience

Sample records for liquid effluent treatments

  1. Waste Treatment Plant Liquid Effluent Treatability Evaluation

    International Nuclear Information System (INIS)

    LUECK, K.J.

    2001-01-01

    Bechtel National, Inc. (BNI) provided a forecast of the radioactive, dangerous liquid effluents expected to be generated by the Waste Treatment Plant (WTP). The forecast represents the liquid effluents generated from the processing of 25 distinct batches of tank waste through the WTP. The WTP liquid effluents will be stored, treated, and disposed of in the Liquid Effluent Retention Facility (LERF) and the Effluent Treatment Facility (ETF). Fluor Hanford, Inc. (FH) evaluated the treatability of the WTP liquid effluents in the LERFIETF. The evaluation was conducted by comparing the forecast to the LERFIETF treatability envelope, which provides information on the items that determine if a liquid effluent is acceptable for receipt and treatment at the LERFIETF. The WTP liquid effluent forecast is outside the current LERFlETF treatability envelope. There are several concerns that must be addressed before the WTP liquid effluents can be accepted at the LERFIETF

  2. WASTE TREATMENT PLANT (WTP) LIQUID EFFLUENT TREATABILITY EVALUATION

    International Nuclear Information System (INIS)

    LUECK, K.J.

    2004-01-01

    A forecast of the radioactive, dangerous liquid effluents expected to be produced by the Waste Treatment Plant (WTP) was provided by Bechtel National, Inc. (BNI 2004). The forecast represents the liquid effluents generated from the processing of Tank Farm waste through the end-of-mission for the WTP. The WTP forecast is provided in the Appendices. The WTP liquid effluents will be stored, treated, and disposed of in the Liquid Effluent Retention Facility (LERF) and the Effluent Treatment Facility (ETF). Both facilities are located in the 200 East Area and are operated by Fluor Hanford, Inc. (FH) for the US. Department of Energy (DOE). The treatability of the WTP liquid effluents in the LERF/ETF was evaluated. The evaluation was conducted by comparing the forecast to the LERF/ETF treatability envelope (Aromi 1997), which provides information on the items which determine if a liquid effluent is acceptable for receipt and treatment at the LERF/ETF. The format of the evaluation corresponds directly to the outline of the treatability envelope document. Except where noted, the maximum annual average concentrations over the range of the 27 year forecast was evaluated against the treatability envelope. This is an acceptable approach because the volume capacity in the LERF Basin will equalize the minimum and maximum peaks. Background information on the LERF/ETF design basis is provided in the treatability envelope document

  3. Liquid Effluent Retention Facility/Effluent Treatment Facility Hazards Assessment

    International Nuclear Information System (INIS)

    Simiele, G.A.

    1994-01-01

    This document establishes the technical basis in support of Emergency Planning activities for the Liquid Effluent Retention Facility and Effluent Treatment Facility the Hanford Site. The document represents an acceptable interpretation of the implementing guidance document for DOE ORDER 5500.3A. Through this document, the technical basis for the development of facility specific Emergency Action Levels and the Emergency Planning Zone is demonstrated

  4. Treatment option evaluation for liquid effluent secondary streams on the Hanford Site

    International Nuclear Information System (INIS)

    Holter, G.M.; Triplett, M.B.; Fow, C.L.; White, M.K.

    1988-08-01

    This study, conducted by the Pacific Northwest Laboratory (PNL) for Westinghouse Hanford Company (WHC), examines the range of secondary waste types and volumes likely to result from treatment of contaminated liquid effluents. Alternatives for treatment of these effluents were considered, taking into account the implementation of the ''best-available technology'' as assumed in current and ongoing engineering studies for treating the various liquid effluent waste streams. These treatment alternatives, and potential variations in the operating schedules for Hanford Site facilities generating contaminated liquid effluents, were evaluated to project an estimated range for the volume of each of the various secondary waste streams that are likely to be generated. The conclusions and recommendations were developed, based on these estimates. 23 refs., 34 figs., 16 tabs

  5. Hanford Facility dangerous waste permit application, liquid effluent retention facility and 200 area effluent treatment facility

    International Nuclear Information System (INIS)

    Coenenberg, J.G.

    1997-01-01

    The Hanford Facility Dangerous Waste Permit Application is considered to 10 be a single application organized into a General Information Portion (document 11 number DOE/RL-91-28) and a Unit-Specific Portion. The scope of the 12 Unit-Specific Portion is limited to Part B permit application documentation 13 submitted for individual, 'operating' treatment, storage, and/or disposal 14 units, such as the Liquid Effluent Retention Facility and 200 Area Effluent 15 Treatment Facility (this document, DOE/RL-97-03). 16 17 Both the General Information and Unit-Specific portions of the Hanford 18 Facility Dangerous Waste Permit Application address the content of the Part B 19 permit application guidance prepared by the Washington State Department of 20 Ecology (Ecology 1987 and 1996) and the U.S. Environmental Protection Agency 21 (40 Code of Federal Regulations 270), with additional information needs 22 defined by the Hazardous and Solid Waste Amendments and revisions of 23 Washington Administrative Code 173-303. For ease of reference, the Washington 24 State Department of Ecology alpha-numeric section identifiers from the permit 25 application guidance documentation (Ecology 1996) follow, in brackets, the 26 chapter headings and subheadings. A checklist indicating where information is 27 contained in the Liquid Effluent Retention Facility and 200 Area Effluent 28 Treatment Facility permit application documentation, in relation to the 29 Washington State Department of Ecology guidance, is located in the Contents 30 Section. 31 32 Documentation contained in the General Information Portion is broader in 33 nature and could be used by multiple treatment, storage, and/or disposal units 34 (e.g., the glossary provided in the General Information Portion). Wherever 35 appropriate, the Liquid Effluent Retention Facility and 200 Area Effluent 36 Treatment Facility permit application documentation makes cross-reference to 37 the General Information Portion, rather than duplicating

  6. Hanford Facility dangerous waste permit application, liquid effluent retention facility and 200 area effluent treatment facility

    Energy Technology Data Exchange (ETDEWEB)

    Coenenberg, J.G.

    1997-08-15

    The Hanford Facility Dangerous Waste Permit Application is considered to 10 be a single application organized into a General Information Portion (document 11 number DOE/RL-91-28) and a Unit-Specific Portion. The scope of the 12 Unit-Specific Portion is limited to Part B permit application documentation 13 submitted for individual, `operating` treatment, storage, and/or disposal 14 units, such as the Liquid Effluent Retention Facility and 200 Area Effluent 15 Treatment Facility (this document, DOE/RL-97-03). 16 17 Both the General Information and Unit-Specific portions of the Hanford 18 Facility Dangerous Waste Permit Application address the content of the Part B 19 permit application guidance prepared by the Washington State Department of 20 Ecology (Ecology 1987 and 1996) and the U.S. Environmental Protection Agency 21 (40 Code of Federal Regulations 270), with additional information needs 22 defined by the Hazardous and Solid Waste Amendments and revisions of 23 Washington Administrative Code 173-303. For ease of reference, the Washington 24 State Department of Ecology alpha-numeric section identifiers from the permit 25 application guidance documentation (Ecology 1996) follow, in brackets, the 26 chapter headings and subheadings. A checklist indicating where information is 27 contained in the Liquid Effluent Retention Facility and 200 Area Effluent 28 Treatment Facility permit application documentation, in relation to the 29 Washington State Department of Ecology guidance, is located in the Contents 30 Section. 31 32 Documentation contained in the General Information Portion is broader in 33 nature and could be used by multiple treatment, storage, and/or disposal units 34 (e.g., the glossary provided in the General Information Portion). Wherever 35 appropriate, the Liquid Effluent Retention Facility and 200 Area Effluent 36 Treatment Facility permit application documentation makes cross-reference to 37 the General Information Portion, rather than duplicating

  7. Waste analysis plan for the 200 area effluent treatment facility and liquid effluent retention facility

    International Nuclear Information System (INIS)

    Ballantyne, N.A.

    1995-01-01

    This waste analysis plan (WAP) has been prepared for startup of the 200 Area Effluent Treatment Facility (ETF) and operation of the Liquid Effluent Retention Facility (LERF), which are located on the Hanford Facility, Richland, Washington. This WAP documents the methods used to obtain and analyze representative samples of dangerous waste managed in these units, and of the nondangerous treated effluent that is discharged to the State-Approved Land Disposal System (SALDS). Groundwater Monitoring at the SALDS will be addressed in a separate plan

  8. Application of reverse osmosis to the treatment of liquid effluents produced by nuclear power plants

    International Nuclear Information System (INIS)

    Huet, Y.; Poulat, B.; Menjeaud, C.

    1989-01-01

    Radioactive liquid effluents generated during the operation of PWR nuclear power units are currently treated by two independent systems. The effluents from the reactor coolant system are recycled, unlike the others, which, after treatment, are released into the river or ocean that provides cooling water for the unit. The objective of the treatment of nonrecycled effluents is to separate from them as much of the radioactive particles that they contain as possible, so as to release into the environment a maximum volume of nonradioactive waste, and to be left with only a minimum volume of concentrated waste, containing most of the initial radioactivity, which must be loaded into casks for storage. Membrane-based filtration techniques, because they have excellent separation performances, can logically be used for this decontamination of the liquid effluents. Having developed its own reverse osmosis membrane, a possible application in a nuclear power plant, i.e., integration of a reverse osmosis unit into a radioactive liquid effluent treatment system is presented. (author)

  9. 200 Area Liquid Effluent Facilities -- Quality assurance program plan

    International Nuclear Information System (INIS)

    Fernandez, L.

    1995-01-01

    This Quality Assurance Program Plan (QAPP) describes the quality assurance and management controls used by the 200 Area Liquid Effluent Facilities (LEF) to perform its activities in accordance with DOE Order 5700.6C. The 200 Area LEF consists of the following facilities: Effluent Treatment Facility (ETF); Treated Effluent Disposal Facility (TEDF); Liquid Effluent Retention facility (LERF); and Truck Loading Facility -- (Project W291). The intent is to ensure that all activities such as collection of effluents, treatment, concentration of secondary wastes, verification, sampling and disposal of treated effluents and solids related with the LEF operations, conform to established requirements

  10. Seminar on long term research into liquid effluent treatment,

    International Nuclear Information System (INIS)

    Hooper, E.W.

    1987-02-01

    A one-day Seminar on Long Term Research into Liquid Waste Treatment was held at Harwell on 30th January 1986. The Seminar was sponsored by the Department of the Environment and was attended by ninety-five delegates representing industry, universities, DoE, CEGB and the AEA. The purpose of the meeting was to provide an opportunity for people working in the field of liquid effluent treatment to obtain up-to-date information on the nature and status of research being carried out in the United Kingdom. Nine presentations on research activity described work being undertaken on ultrafiltration and associated techniques, electrical processes and ion exchange. The presenters were from BNF plc, CEGB, Imperial College, University of Salford, University of Reading and from Harwell. (author)

  11. INEEL Liquid Effluent Inventory

    Energy Technology Data Exchange (ETDEWEB)

    Major, C.A.

    1997-06-01

    The INEEL contractors and their associated facilities are required to identify all liquid effluent discharges that may impact the environment at the INEEL. This liquid effluent information is then placed in the Liquid Effluent Inventory (LEI) database, which is maintained by the INEEL prime contractor. The purpose of the LEI is to identify and maintain a current listing of all liquid effluent discharge points and to identify which discharges are subject to federal, state, or local permitting or reporting requirements and DOE order requirements. Initial characterization, which represents most of the INEEL liquid effluents, has been performed, and additional characterization may be required in the future to meet regulations. LEI information is made available to persons responsible for or concerned with INEEL compliance with liquid effluent permitting or reporting requirements, such as the National Pollutant Discharge Elimination System, Wastewater Land Application, Storm Water Pollution Prevention, Spill Prevention Control and Countermeasures, and Industrial Wastewater Pretreatment. The State of Idaho Environmental Oversight and Monitoring Program also needs the information for tracking liquid effluent discharges at the INEEL. The information provides a baseline from which future liquid discharges can be identified, characterized, and regulated, if appropriate. The review covered new and removed buildings/structures, buildings/structures which most likely had new, relocated, or removed LEI discharge points, and at least 10% of the remaining discharge points.

  12. The treatment of effluents

    International Nuclear Information System (INIS)

    Wormser, G.; Rodier, J.; Robien, E. de; Fernandez, N.

    1964-01-01

    For several years the French Atomic Energy Commission has been studying with interest problems presented by radio-active effluents. Since high activities have not yet received a definite solution we will deal only, in this paper, with the achievements and research concerning low and medium activity effluents. In the field of the achievements, we may mention the various effluent treatment stations which have been built in France; a brief list will be given together with an outline of their main new features. Thus in particular the latest treatment stations put into operation (Grenoble, Fontenay-aux-Roses, Cadarache) will be presented. From all these recent achievements three subjects will be dealt with in more detail. 1 - The workshop for treating with bitumen the sludge obtained after concentration of radionuclides. 2 - The workshop for treating radioactive solid waste by incineration. 3 - A unit for concentrating radio-active liquid effluents by evaporation. In the field of research, several topics have been undertaken, a list will be given. In most cases the research concerns the concentration of radionuclides with a view to a practical and low cost storage, a concentration involving an efficient decontamination of the aqueous liquids in the best possible economic conditions. For improving the treatments leading to the concentration of nuclides, our research has naturally been concerned with perfecting the treatments used in France: coprecipitation and evaporation. In our work we have taken into account in particular two conditions laid down in the French Centres. 1 - A very strict sorting out of the effluents at their source in order to limit in each category the volume of liquid to be dealt with. 2 - The necessity for a very complete decontamination due to the high population density in our country. In the last past we present two original methods for treating liquid effluents. 1 - The use of ion-exchange resins for liquids containing relatively many salts. The

  13. Treatment of liquid effluent from uranium mines and mills. Report of a co-ordinated research project 1996-2000

    International Nuclear Information System (INIS)

    2004-10-01

    Treatment and control of liquid effluents produced during uranium mining and milling operations is an integral part of environmental project management. Research has continued to add to the large body of science that has been built up around the treatment of radioactive and non-radioactive effluents to minimize their long-term environmental impact. The objective of the meetings on which this publication is based was to exchange information on active effluent treatment technologies that have application during operations and passive treatment techniques such as constructed wetlands and use of micro-organisms that are applicable during project reclamation and long-term care and maintenance. Papers describe effluent treatment case histories from active uranium mining and processing operations as well as effluent treatment research on both active and passive systems that have potential application under a wide range of operating and post-operational conditions including new information on high-density sludge from effluent neutralization (Australia), aerated manganese hydroxide for removal of radium (China), nanofiltration and macropore resins to treat mine water (Australia and China), in situ microbial treatment and permeable reactive walls for treatment of contaminated groundwater (Germany), construction of wetlands to treat mine water runoff (Australia and Germany), biogenic granules to remove 226 Ra from mill effluent (India), self-remediation of acidic in situ leach aquifers (Kazakhstan) and sorption characteristics of soil for self-remediation of contaminated groundwater (Hungary). These and other topics presented in this publication will be of interest to technical personnel who deal with day-to-day practical aspects of liquid effluent control and treatment at uranium production facilities worldwide

  14. Supercritical water oxidation test bed effluent treatment study

    International Nuclear Information System (INIS)

    Barnes, C.M.

    1994-04-01

    This report presents effluent treatment options for a 50 h Supercritical Water Test Unit. Effluent compositions are calculated for eight simulated waste streams, using different assumed cases. Variations in effluent composition with different reactor designs and operating schemes are discussed. Requirements for final effluent compositions are briefly reviewed. A comparison is made of two general schemes. The first is one in which the effluent is cooled and effluent treatment is primarily done in the liquid phase. In the second scheme, most treatment is performed with the effluent in the gas phase. Several unit operations are also discussed, including neutralization, mercury removal, and evaporation

  15. Liquid effluent at Dounreay

    International Nuclear Information System (INIS)

    Sinclair, N.R.

    1995-01-01

    This short paper reviews the liquid effluent treatment at the Dounreay site. The significant reductions in volume and activity discharged from the site to the environment have been achieved over the many years of operation, and some of the techniques are highlighted. The Regulator interaction and the effect on the environment is discussed, while some of the requirements of the Regulator are presented. (author)

  16. The management plan of liquid effluent in Korean advanced light water reactor

    International Nuclear Information System (INIS)

    Kim, S. H.; Lim, H. S.; Jeong, D. W.; Jeong, D. Y.

    2001-01-01

    Non-radioactive liquid effluent in Korean Advanced Light Water Reactor is transferred and treated in centralized waste treatment facility after the radioactivity in effluent is checked within power block. The liquid effluent from centralized waste treatment facility will be discharged by way of discharge canal in order to be in the sufficient condition. As a result of investigating the radiation monitoring design in accordance with 20 provisions by Korean Regulatory Authority, each effluent radiation monitoring with 20 provisions by Korean Regulatory Authority, each effluent radiation monitoring design satisfies the regulatory guideline. In relation to sampling and analyses, most systems satisfy the regulatory guideline except for some effluents from turbine building. And, though sampling and analyses are performed after radioactivity is monitored at each system in turbine building, these exceptions in turbine building effluents are expected to cause no significant problems because radioactivity is monitored by direct or indirect methods prior to release from turbine building. Integrated monitoring on liquid effluent from the centralized waste water treatment facility is not necessary because radiation monitoring, sampling and analyses on each system within power block are performed, and operational effectiveness compared with cost according to adding the radiation monitoring equipment is too low. So, whether the radiation monitoring in this effluent is reflected on design or not is planned to be determined through discussion with regulatory authority

  17. A risk-based approach to liquid effluent monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Hull, L.C.

    1995-10-01

    DOE Order 5400.1 identifies six objectives of a liquid effluent monitoring program. A strategy is proposed that meets these objective in one of two ways: (1) by showing that effluent concentrations are below concentration limits set by permits or are below concentrations that could cause environmental problems or (2) by showing that concentrations in effluent have not changed from a period when treatment processes were in control and there were no unplanned releases. The intensity of liquid effluent monitoring should be graded to the importance of the source being monitored. This can be accomplished by determining the risk posed by the source. A definition of risk is presented that defines risk in terms of the statistical probability of exceeding a release limit and the time available to recover from an exceedance of a release limit. Three examples are presented that show this approach to grading an effluent monitoring program can be implemented at the Idaho National Engineering Laboratory and will reduce monitoring requirements.

  18. A risk-based approach to liquid effluent monitoring

    International Nuclear Information System (INIS)

    Hull, L.C.

    1995-10-01

    DOE Order 5400.1 identifies six objectives of a liquid effluent monitoring program. A strategy is proposed that meets these objective in one of two ways: (1) by showing that effluent concentrations are below concentration limits set by permits or are below concentrations that could cause environmental problems or (2) by showing that concentrations in effluent have not changed from a period when treatment processes were in control and there were no unplanned releases. The intensity of liquid effluent monitoring should be graded to the importance of the source being monitored. This can be accomplished by determining the risk posed by the source. A definition of risk is presented that defines risk in terms of the statistical probability of exceeding a release limit and the time available to recover from an exceedance of a release limit. Three examples are presented that show this approach to grading an effluent monitoring program can be implemented at the Idaho National Engineering Laboratory and will reduce monitoring requirements

  19. Liquid Effluent Retention Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Liquid Effluent Retention Facility (LERF) is located in the central part of the Hanford Site. LERF is permitted by the State of Washington and has three liquid...

  20. Control system of liquid effluents generated in treatment with I-131

    International Nuclear Information System (INIS)

    Garcia M, T.; Ruiz C, M. A.; Angeles C, A.; Ramirez S, R.

    2015-09-01

    In recent years, nuclear medicine has developed greatly in our country and around the world. Techniques for both medical diagnosis and therapy have increased the use of radiopharmaceuticals, notably the I-131. In Mexico there are around 150 nuclear medicine establishments authorized by the Comision Nacional de Seguridad Nuclear y Salvaguardias. Most of these establishments do not have an appropriate facility for the treatment of radioactive liquid effluents, to ensure compliance with the concentration limits established in the regulations. The Instituto Nacional de Investigaciones Nucleares (ININ) developed and implemented successfully, a control system of radioactive effluents (named SACEL) from a nuclear medicine facility. This system ensures an effective compliance with regulations and also better management and control of these radioactive effluents. Calculations and design of SACEL were made with respect to I-131, because is one of the most commonly used in radiotherapy and medical diagnostics, besides its half-life is greater in relation to other radionuclides. SACEL is comprised of four storage tanks and decay and a fifth tank for measuring the concentration of I-131 and later discharge to the drain; these tanks are connected to an automated system that controls the effluents passage. The calculation to determine the volume of the tanks was carried out according to the demand that has the hospital, to the maximum activity being poured in effluents and time required to decay. In this paper the design and installation of SACEL system, in addition to functioning as a facility that enables the Hospital meet the required standards is presented. Dose calculations performed with MCNPX and the methodology used in the calibration of the detection system is also presented. (Author)

  1. Legal provisions governing liquid effluents radiological monitoring

    International Nuclear Information System (INIS)

    Gans, I.; Ruehle, H.

    1985-01-01

    The KTA rule 1504 for radiological monitoring of liquid effluents from nuclear installations is explained. As there are no such rules published to date for establishments handling isotopes, some criteria are discussed which in the future ought to form part of a practical guide for liquid effluents monitoring in isotope handling installations. Monitoring measures described refer to liquid effluents from transfer containers, auxiliary cooling equipment, turbine buildings, main cooling installations, and waste air discharges from closed-circuit cooling systems. (DG) [de

  2. Liquid Effluent Monitoring Information System (LEMIS) System Construction

    International Nuclear Information System (INIS)

    Adams, R.T.

    1994-01-01

    The liquid effluent sampling program is part of the effort to minimize adverse environmental impact during the cleanup operation at the Hanford Site. Of the 33 Phase I and Phase II liquid effluents, all streams actively discharged to the soil column will be sampled. The Liquid Effluent Monitoring Information System (LEMIS) is being developed as the organized information repository facility in support of the liquid effluent monitoring requirements of the Tri-Party Agreement. It is necessary to provide an automated repository into which the results from liquid effluent sampling will be placed. This repository must provide for effective retention, review, and retrieval of selected sample data by authorized persons and organizations. This System Construction document is the aggregation of the DMR P+ methodology project management deliverables. Together they represent a description of the project and its plan through four Releases, corresponding to the definition and prioritization of requirements defined by the user

  3. Treatment of effluent at the Saclay Centre d'Etudes Nucleaires (1960); Le traitement des effluents du Centre d'Etudes Nucleaires de Saclay (1960)

    Energy Technology Data Exchange (ETDEWEB)

    Wormser, G [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    The Centre d'Etudes Nucleaires at Saclay possesses several installations from which liquid radioactive effluent is rejected, and it has thus been found necessary to construct a station for the purification of radioactive liquids and to settle various chemical, analytical and technological problems. This report describes, in the following order: - the disposal possibilities at the Centre d'Etudes Nucleaires, Saclay, - the effluents produced at the centre, - the set-up for collecting effluent, - treatment of the effluent, - results of these treatments. (author) [French] La presence, au Centre d'Etudes Nucleaires de Saclay, de plusieurs installations susceptibles de rejeter des effluents liquides radioactifs a necessite la construction d'une station d'epuration d'eaux radioactives et la mise au point de differents problemes chimiques, analytiques et technologiques. Dans ce rapport, nous exposerons successivement: - les possibilites de rejet du Centre d'Etudes Nucleaires de Saclay, - les effluents du centre, - le dispositif de collecte des effluents, - le traitement de ces effluents, - les resultats de ces traitements. (auteur)

  4. Fertilizer potential of liquid and solid effluent from thermophilic anaerobic digestion of poultry waste.

    Science.gov (United States)

    Liedl, B E; Bombardiere, J; Chaffield, J M

    2006-01-01

    Thermophilic anaerobic treatment of poultry litter produces an effluent stream of digested materials that can be separated into solid and liquid fractions for use as a crop fertilizer. The majority of the phosphorus is partitioned into the solid fraction while the majority of the nitrogen is present in the liquid fraction in the form of ammonium. These materials were tested over six years as an alternative fertilizer for the production of vegetable, fruit, and grassland crops. Application of the solids as a field crop fertilizer for vegetables and blueberries resulted in lower yields than the other fertilizer treatments, but an increase in soil phosphorus over a four-year period. Application of the digested liquids on grass and vegetable plots resulted in similar or superior yields to plots treated with commercially available nitrogen fertilizers. Hydroponic production of lettuce using liquid effluent was comparable to a commercial hydroponic fertilizer regime; however, the effluent treatment for hydroponic tomato production required supplementation and conversion of ammonium to nitrate. While not a total fertilizer solution, our research shows the effectiveness of digested effluent as part of a nutrient management program which could turn a livestock residuals problem into a crop nutrient resource.

  5. Computer software configuration management plan for 200 East/West Liquid Effluent Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Graf, F.A. Jr.

    1995-02-27

    This computer software management configuration plan covers the control of the software for the monitor and control system that operates the Effluent Treatment Facility and its associated truck load in station and some key aspects of the Liquid Effluent Retention Facility that stores condensate to be processed. Also controlled is the Treated Effluent Disposal System`s pumping stations and monitors waste generator flows in this system as well as the Phase Two Effluent Collection System.

  6. Computer software configuration management plan for 200 East/West Liquid Effluent Facilities

    International Nuclear Information System (INIS)

    Graf, F.A. Jr.

    1995-01-01

    This computer software management configuration plan covers the control of the software for the monitor and control system that operates the Effluent Treatment Facility and its associated truck load in station and some key aspects of the Liquid Effluent Retention Facility that stores condensate to be processed. Also controlled is the Treated Effluent Disposal System's pumping stations and monitors waste generator flows in this system as well as the Phase Two Effluent Collection System

  7. Effluent treatment plant and decontamination centre, Trombay

    International Nuclear Information System (INIS)

    Kaushik, C.P.; Agarwal, K.

    2017-01-01

    The Bhabha Atomic Research Centre, Trombay, has a number of plants and laboratories, which generate Radioactive Liquid Waste and Protective Wears. Two facilities have been established in late 1960s to cater to this requirement. The Centre, on the average generates about 50,000 m"3 of active liquid effluents of varying specific activities. The Effluent Treatment Plant was setup to receive and process radioactive liquids generated by various facilities of BARC in Trombay. It also serves a single-point discharge facility to enable monitoring of radioactive effluents discharged from the Trombay site. About 120-150 Te of protective wears and inactive apparel are generated annually from various radioactive facilities and laboratories of BARC. In addition, contaminated fuel assembly components are generated by DHRUVA and formerly by CIRUS. These components require decontamination before its recycle to the fuel assembly process. The Decontamination Centre, setup in late 1960s, is mandated to carry out the above mentioned decontamination activities

  8. Complete physico-chemical treatment for coke plant effluents.

    Science.gov (United States)

    Ghose, M K

    2002-03-01

    Naturally found coal is converted to coke which is suitable for metallurgical industries. Large quantities of liquid effluents produced contain a large amount of suspended solids, high COD, BOD, phenols, ammonia and other toxic substances which are causing serious pollution problem in the receiving water to which they are discharged. There are a large number of coke plants in the vicinity of Jharia Coal Field (JCF). Characteristics of the effluents have been evaluated. The present effluent treatment systems were found to be inadequate. Physico-chemical treatment has been considered as a suitable option for the treatment of coke plant effluents. Ammonia removal by synthetic zeolite, activated carbon for the removal of bacteria, viruses, refractory organics, etc. were utilized and the results are discussed. A scheme has been proposed for the complete physico-chemical treatment, which can be suitably adopted for the recycling, reuse and safe disposal of the treated effluent. Various unit process and unit operations involved in the treatment system have been discussed. The process may be useful on industrial scale at various sites.

  9. Radiological characterization of liquid effluent hold up tank for generating data base for future decommissioning

    International Nuclear Information System (INIS)

    Sapkal, Jyotsna A.; Singh, Pratap; Verma, Amit; Yadav, R.K.B.; Thakare, S.V.

    2018-01-01

    Operations at Radiological laboratory facilities are involved in fabrication of high activity radioactive sources like 60 Co, 192 1r and 137 Cs, handling of long lived radionuclides like 137 Cs/ 90 Sr, radiochemical processing and production of short-lived radioisotopes for medical diagnosis and treatment of patients. Typical liquid waste management feature at any Radiological Laboratory facility primarily consists of effluent tanks which store the liquid effluent wastes generated during radiochemical processing and fabrication of reactor produced radioisotopes. The liquid waste generated from various laboratories are collected to low level sump tanks from where it is transferred to hold up tanks. The liquid waste is transferred to centralized effluent treatment plant, analysis and characterization of the same is carried out. This paper explains the characterization study of samples drawn from the liquid effluent tank which would be helpful for planning for decontamination as well as for decommissioning and in management of radioactive wastes. In this study the crud deposited at the bottom of tank was collected for gamma spectrometry analysis. Radiation field was measured, at the bottom of the tank for correlating the activity present and the radiation field

  10. Liquid Effluents Program mission analysis

    International Nuclear Information System (INIS)

    Lowe, S.S.

    1994-01-01

    Systems engineering is being used to identify work to cleanup the Hanford Site. The systems engineering process transforms an identified mission need into a set of performance parameters and a preferred system configuration. Mission analysis is the first step in the process. Mission analysis supports early decision-making by clearly defining the program objectives, and evaluating the feasibility and risks associated with achieving those objectives. The results of the mission analysis provide a consistent basis for subsequent systems engineering work. A mission analysis was performed earlier for the overall Hanford Site. This work was continued by a ''capstone'' team which developed a top-level functional analysis. Continuing in a top-down manner, systems engineering is now being applied at the program and project levels. A mission analysis was conducted for the Liquid Effluents Program. The results are described herein. This report identifies the initial conditions and acceptable final conditions, defines the programmatic and physical interfaces and sources of constraints, estimates the resources to carry out the mission, and establishes measures of success. The mission analysis reflects current program planning for the Liquid Effluents Program as described in Liquid Effluents FY 1995 Multi-Year Program Plan

  11. Effluent and water treatment at AERE Harwell

    International Nuclear Information System (INIS)

    Lewis, J.B.

    1977-01-01

    The treatment of liquid wastes at Harwell is based on two main principles: separation of surface water, domestic sewage, trade wastes and radioactive effluents at source, and a system of holding tanks which are sampled so that the appropriate treatment can be given to any batch. All discharges are subject to independent monitoring by the authorising departments and the Thames Water Inspectors. (author)

  12. Elimination of liquid discharge to the environment from the TA-50 Radioactive Liquid Waste Treatment Facility

    International Nuclear Information System (INIS)

    Moss, D.; Williams, N.; Hall, D.; Hargis, K.; Saladen, M.; Sanders, M.; Voit, S.; Worland, P.; Yarbro, S.

    1998-06-01

    Alternatives were evaluated for management of treated radioactive liquid waste from the radioactive liquid waste treatment facility (RLWTF) at Los Alamos National Laboratory. The alternatives included continued discharge into Mortandad Canyon, diversion to the sanitary wastewater treatment facility and discharge of its effluent to Sandia Canyon or Canada del Buey, and zero liquid discharge. Implementation of a zero liquid discharge system is recommended in addition to two phases of upgrades currently under way. Three additional phases of upgrades to the present radioactive liquid waste system are proposed to accomplish zero liquid discharge. The first phase involves minimization of liquid waste generation, along with improved characterization and monitoring of the remaining liquid waste. The second phase removes dissolved salts from the reverse osmosis concentrate stream to yield a higher effluent quality. In the final phase, the high-quality effluent is reused for industrial purposes within the Laboratory or evaporated. Completion of these three phases will result in zero discharge of treated radioactive liquid wastewater from the RLWTF

  13. Elimination of liquid discharge to the environment from the TA-50 Radioactive Liquid Waste Treatment Facility

    Energy Technology Data Exchange (ETDEWEB)

    Moss, D.; Williams, N.; Hall, D.; Hargis, K.; Saladen, M.; Sanders, M.; Voit, S.; Worland, P.; Yarbro, S.

    1998-06-01

    Alternatives were evaluated for management of treated radioactive liquid waste from the radioactive liquid waste treatment facility (RLWTF) at Los Alamos National Laboratory. The alternatives included continued discharge into Mortandad Canyon, diversion to the sanitary wastewater treatment facility and discharge of its effluent to Sandia Canyon or Canada del Buey, and zero liquid discharge. Implementation of a zero liquid discharge system is recommended in addition to two phases of upgrades currently under way. Three additional phases of upgrades to the present radioactive liquid waste system are proposed to accomplish zero liquid discharge. The first phase involves minimization of liquid waste generation, along with improved characterization and monitoring of the remaining liquid waste. The second phase removes dissolved salts from the reverse osmosis concentrate stream to yield a higher effluent quality. In the final phase, the high-quality effluent is reused for industrial purposes within the Laboratory or evaporated. Completion of these three phases will result in zero discharge of treated radioactive liquid wastewater from the RLWTF.

  14. Flow proportional sampling of low level liquid effluent

    International Nuclear Information System (INIS)

    Colley, D.; Jenkins, R.

    1989-01-01

    A flow proportional sampler for use on low level radioactive liquid effluent has been developed for installation on all CEGB nuclear power stations. The sampler, operates by drawing effluent continuously from the main effluent pipeline, through a sampler loop and returning it to the pipeline. The effluent in this loop is sampled by taking small, frequent aliquots using a linear acting shuttle valve. The frequency of operation of this valve is controlled by a flowmeter installed in the effluent line; sampling rate being directly proportional to effluent flowrate. (author)

  15. Treatment of ORNL liquid low-level waste

    International Nuclear Information System (INIS)

    Berry, J.B.; Brown, C.H. Jr.; Fowler, V.L.; Robinson, S.M.

    1988-01-01

    Discontinuation of the hydrofracture disposal method at Oak Ridge National Laboratory (ORNL) has caused intensive efforts to reduce liquid waste generation. Improving the treatment of slightly radioactive liquid waste, called process waste, has reduced the volume of the resulting contaminated liquid radioactive waste effluent by 66%. Proposed processing improvements could eliminate the contaminated liquid effluent and reduce solid low-level waste by an additional one-third. The improved process meets stringent discharge limits for radionuclides. Discharge limits for radionuclides are expected to be enforced at the outfall of the treatment plant to a creek; currently, limits are enforced at the reservation boundary. Plant discharge is monitored according to the National Pollutant Discharge Elimination System (NPDES) permit for ORNL. 1 ref., 4 figs., 2 tabs

  16. Recycling liquid effluents in a ceramic industry

    International Nuclear Information System (INIS)

    Araujo Almeida, B.; Almeida, M.; Martins, S.; Alexandra Macarico, V.; Tomas da Fonseca, A.

    2016-01-01

    In this work is presented a study on the recycling of liquid effluents in a ceramic installation for sanitary industry. The effluents were characterized by X-ray diffraction and inductively coupled plasma to evaluate their compositions. It was also assessed the daily production rate. Several glaze-slurry mixtures were prepared and characterized according to procedures and equipment of the company's quality laboratory. The results show that for most of the properties, the tested mixtures exhibited acceptable performance. However, the pyro plasticity parameter is highly influenced by the glaze content and imposes the separation of glaze and slurry liquid effluents. In addition, it is necessary to invest on a storage plant, including tanks with constant stirring and a new pipeline structure to implement the reincorporation method on the slurry processing. (Author)

  17. Recovery of sludge from the treatment of liquid radioactive effluents by co-precipitation with calcium carbonate: laboratory study; Recuperation des boues de traitement des effluents radioactifs liquides par coprecipitation avec le carbonate de calcium: etude de laboratoire

    Energy Technology Data Exchange (ETDEWEB)

    Patti, F.; Gailledreau, C.; Cohen, P.

    1961-02-24

    As during the treatment by co-precipitation with calcium carbonate of liquid radioactive residues, a partial decontamination can be obtained by simply agitating an already formed radioactive sludge with the effluent to be processed, the authors study whether it would be possible to first perform a co-precipitation with a lower dose of calcium carbonate and then to complete decontamination by agitating with an adequate quantity of sludge stored during preceding operations. The authors report the study of the influence of reactant quantity on the chemical treatment efficiency, of the evolution of the activity of a radioactive residual solution in contact with a precipitate, of the cleaner element, of a precipitate reuse, of the technological and economic aspects, and of another possibility of reduction of the precipitate volume [French] Dans le traitement par coprecipitation avec le carbonate de calcium des residus radioactifs liquides, une decontamination partielle peut etre obtenue en agitant simplement une boue radioactive deja formee avec l'effluent a traiter. En consequence, il pourrait etre possible d'effectuer d'abord une coprecipitation avec une dose plus faible de carbonate de calcium et de completer ensuite la decontamination en agitant le liquide avec une quantite convenable de boue stockee a partir d'operations precedentes. (auteurs)

  18. Monitoring of released radioactive gaseous and liquid effluent at Rokkasho Reprocessing Plant

    International Nuclear Information System (INIS)

    Oka, M.; Keta, S.; Nagai, S.; Kano, M.; Ishihara, N.; Moriyama, T.; Ogaki, K.; Noda, K.

    2009-01-01

    Rokkasho Reprocessing Plant (RRP) Rokkasho Reprocessing Plant started its active tests with spent fuel at the end of March 2006. When spent fuels are sheared and dissolved, radioactive gaseous effluent and radioactive liquid effluent such as krypton-85, tritium, etc. are released into the environment. In order to limit the public dose as low as reasonably achievable in an efficient way, RRP removes radioactive material by evaporation, rinsing, filtering, etc., and then releases it through the main stack and the sea discharge pipeline that allow to make dispersion and dilution very efficiently. Also, concerning the radioactive gaseous and liquid effluent to be released into the environment, the target values of annual release have been defined in the Safety Rule based on the estimated annual release evaluated at the safety review of RRP. By monitoring the radioactive material in gaseous exhaust and liquid effluent RRP controls it not to exceed the target values. RRP reprocessed 430 tUpr of spent fuel during Active Test (March 2006 to October 2008). In this report, we report about: The outline of gaseous and liquid effluent monitoring. The amount of radioactive gaseous and liquid effluent during the active test. The performance of removal of radioactive materials in gaseous and liquid effluents. The impact on the public from radioactive effluents during the active test. (author)

  19. Treatment of liquid wastes from uranium hydrometallurgy

    International Nuclear Information System (INIS)

    Moraga G, J.C.

    1988-01-01

    Different treatments for low activity liquid wastes, generated by the hidromettalurgy of uranium ore are studied. A process of treatment was chosen which includes a neutralization with lime and limestone and a selective removal of Ra-226, through ion-exchange resins. A plant, with a capacity of treatment of 1 m 3 /h of liquid effluents was scoped. (author)

  20. The treatment of liquid effluents of reprocessing plants by a chemical process: French experience

    International Nuclear Information System (INIS)

    Fernandez, N.; Taillard, D.

    1977-01-01

    The goal of radioactive effluent processing is to obtain a liquid with a residual activity level allowing disposal and a minimum amount of slurries. Insolubilization methods used in France are described to eliminate fission products in reprocessing plants effluents i.e. strontium, cesium, ruthenium and antimony; others radioelements are generally carried away with others precipitates. Evolution of the process is expressed in terms of reprocessing needs and improvements. Decontamination factors better than 100 are now possible with concentration factors between 30 and 50 [fr

  1. Criticality safety issues arising from the treatment of liquid effluent streams from the reprocessing of thermal oxide fuel

    International Nuclear Information System (INIS)

    Thorne, P.R.; Farrington, L.M.

    1991-01-01

    The BNFL THORP plant will reprocess irradiated oxide fuel from thermal reactors to recover plutonium dioxide and uranium trioxide in a pure form. A consequence of the reprocessing is that several liquid effluent streams are produced which can contain residual fissile material. Generally, the treatment of these effluent streams is carried out in large vessels which are not geometrically favourable with regard to nuclear safety. This is possible because the concentration of fissile material in solution is far less than the safely subcritical infinite sea concentrations. The situation is complicated by the presence of precipitated solids in some vessels and crud layers in others. Experimental measurements have been used to characterise these solids in order to extend the usual safe limits, and to provide an acceptable operating regime. Based on the experimental characterisation of the solids, the neutronics computer codes WIMS and MONK have been used to determine the optimum possible conditions existing, and to determine the safe fissile mass limits for these systems. The limits which are derived have been used to provide alarm and trip levels for instrumentation which has been employed in a novel way. It has been shown that the plant can be operated successfully and remains acceptably safe taking into account the presence of solids in the liquid effluent streams. (author)

  2. Liquid Effluent Monitoring Information System test plans release 1.2

    International Nuclear Information System (INIS)

    Adams, R.T.

    1994-01-01

    The Liquid Effluent Monitoring Information System (LEMIS) is being developed as the organized information repository facility in support of the liquid effluent monitoring requirements of the Tri-Party Agreement. It is necessary to provide an automated repository into which the results from liquid effluent sampling will be placed. This repository must provide for effective retention, review, and retrieval of selected sample data by authorized persons and organizations. This System Architecture document is the aggregation of the DMR P+ methodology project management deliverables. Together they represent a description of the project and its plan through four Releases, corresponding to the definition and prioritization of requirements defined by the user

  3. 242-A Evaporator/Liquid Effluent Retention Facility data quality objectives

    International Nuclear Information System (INIS)

    Von Bargen, B.H.

    1994-01-01

    The purpose of data quality objectives (DQO) is to determine the most cost effective methods of gathering the essential data necessary to make decisions to support successful operation of the facility. The essential data is defined by such information as sample amount, sample location, required analyses, and how sampling and analyses are performed. Successful operation is defined as meeting the campaign objectives while operating within established requirements. This DQO document addresses that portion of the system from 242-A Evaporator candidate feed tanks through discharge of process condensate to the Liquid Effluent Retention of Facility (LERF). Later revisions will incorporate and integrate the entire system, including the Effluent Treatment Facility (ETF)

  4. 242-A Evaporator/Liquid Effluent Retention Facility data quality objectives

    Energy Technology Data Exchange (ETDEWEB)

    Von Bargen, B.H.

    1994-09-29

    The purpose of data quality objectives (DQO) is to determine the most cost effective methods of gathering the essential data necessary to make decisions to support successful operation of the facility. The essential data is defined by such information as sample amount, sample location, required analyses, and how sampling and analyses are performed. Successful operation is defined as meeting the campaign objectives while operating within established requirements. This DQO document addresses that portion of the system from 242-A Evaporator candidate feed tanks through discharge of process condensate to the Liquid Effluent Retention of Facility (LERF). Later revisions will incorporate and integrate the entire system, including the Effluent Treatment Facility (ETF).

  5. Assessment of Radioactive Liquid Effluents Release at IPEN-CNEN/SP

    International Nuclear Information System (INIS)

    Bessa Nisti, Marcelo; Godoy dos Santos, Adir Janete

    2008-01-01

    A continuous effluent monitoring program has been established at IPEN's plant in order to allow an environmental impact assessment due to radioactive liquid effluent discharge to sanitary system. Representative samples of radioactive liquid effluents are analyzed by using high resolution gamma spectroscopy and instrumental neutron activation analysis, facing to Brazilian radioprotection regulatory rules. The results are consolidating yearly in the Institute source-term. In this paper, results of the source-term are presented, concerning to years 2004, 2005 and 2006. The total activity discharged was 8.5xl0 8 Bq, 5.7x10 8 Bq and 2.7xl0 8 Bq, respectively. As the release is strongly dependent on the total amount of the effluent and on the dilution factor, special attention is needed in order to obtain the correct value of that last one. The estimated inside plant dilution factor, considering the recent facilities and the reshaping of the sewerage system was 80, 180 and 130, for period of 2004, 2005 and 2006 discharged liquid radioactive effluent

  6. The use of supported liquid membranes in the treatment of mining effluents

    International Nuclear Information System (INIS)

    Hebden, D.; Smit, J.J.

    1984-01-01

    The acid barren effluents from uranium extraction plants contain a number of dissolved metals although these are often only in trace concentrations. Whilst recovery of these minerals for economic gain has been considered in the past, the removal of some of these minerals is now even more desirable in view of environmental considerations. It is in this application that the supported liquid membrane system finds a model application, with its ability to treat large volumes of unclarified waters, with minimal solvent losses, and selectivity of ion removal. This paper presents current research into this supported liquid membrane application and reviews techniques and costs, in the light of present knowledge. (author)

  7. Liquid effluent processing group. Activity details 1963

    International Nuclear Information System (INIS)

    1964-08-01

    This report first gives a quantitative overview of volumes of effluents of high activity, medium activity and low activity which passed through the department for effluent processing. It also makes the distinction between the shape or type of container of these effluents. A table indicates their origin and another indicates their destination. The β and α decontamination rates are determined, and the assessment of stored aqueous and organic effluents on the 31 December 1963 is given. The next part proposes an assessment of laboratory activities: control operations (input controls, control of processed effluent before discarding), controls related to processing (processing types, radiochemical and chemical dosing performed on effluent mixes before processing). Tables indicate the characteristics of medium activity effluents collected in 1963, the results of high activity liquid analysis, and Beryllium dosing results. A summary of ALEA processing, a table of the characteristics of stored oils and solvents are given. The third part reports data related to transport activities, and various works performed in the Saclay plant to improve exploitation conditions and results

  8. The treatment of effluents; Ameliorations apportees aux traitements des residus radioactifs

    Energy Technology Data Exchange (ETDEWEB)

    Wormser, G; Rodier, J; Robien, E de; Fernandez, N [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1964-07-01

    For several years the French Atomic Energy Commission has been studying with interest problems presented by radio-active effluents. Since high activities have not yet received a definite solution we will deal only, in this paper, with the achievements and research concerning low and medium activity effluents. In the field of the achievements, we may mention the various effluent treatment stations which have been built in France; a brief list will be given together with an outline of their main new features. Thus in particular the latest treatment stations put into operation (Grenoble, Fontenay-aux-Roses, Cadarache) will be presented. From all these recent achievements three subjects will be dealt with in more detail. 1 - The workshop for treating with bitumen the sludge obtained after concentration of radionuclides. 2 - The workshop for treating radioactive solid waste by incineration. 3 - A unit for concentrating radio-active liquid effluents by evaporation. In the field of research, several topics have been undertaken, a list will be given. In most cases the research concerns the concentration of radionuclides with a view to a practical and low cost storage, a concentration involving an efficient decontamination of the aqueous liquids in the best possible economic conditions. For improving the treatments leading to the concentration of nuclides, our research has naturally been concerned with perfecting the treatments used in France: coprecipitation and evaporation. In our work we have taken into account in particular two conditions laid down in the French Centres. 1 - A very strict sorting out of the effluents at their source in order to limit in each category the volume of liquid to be dealt with. 2 - The necessity for a very complete decontamination due to the high population density in our country. In the last past we present two original methods for treating liquid effluents. 1 - The use of ion-exchange resins for liquids containing relatively many salts. The

  9. 200 area liquid effluent facility quality assurance program plan. Revision 1

    International Nuclear Information System (INIS)

    Sullivan, N.J.

    1995-01-01

    Direct revision of Supporting Document WHC-SD-LEF-QAPP-001, Rev. 0. 200 Area Liquid Effluent Facilities Quality Assurance Program Plan. Incorporates changes to references in tables. Revises test to incorporate WHC-SD-LEF-CSCM-001, Computer Software Configuration Management Plan for 200 East/West Liquid Effluent Facilities

  10. Liquid Effluent Monitoring Information System (LEMIS) test plans release 1.0

    International Nuclear Information System (INIS)

    Adams, R.T.

    1994-01-01

    The Liquid Effluent Monitoring Information System (LEMIS) is being developed as the organized information repository facility in support of the liquid effluent monitoring requirements of the Tri-Party Agreement. It is necessary to provide an automated repository into which the results from liquid effluent sampling will be placed. This repository must provide for effective retention, review, and retrieval of selected sample data by authorized persons and organizations. This System Architecture document is the aggregation of the DMR P+ methodology project management deliverables. Together they represent a description of the project and its plan through four Releases, corresponding to the definition and prioritization of requirements defined by the user

  11. Liquid Effluent Monitoring Information System (LEMIS) test plans release 1.1

    International Nuclear Information System (INIS)

    Adams, R.T.

    1994-01-01

    The Liquid Effluent Monitoring Information System (LEMIS) is being developed as the organized information repository facility in support of the liquid effluent monitoring requirements of the Tri-Party Agreement. It is necessary to provide an automated repository into which the results from liquid effluent sampling will be placed. This repository must provide for effective retention, review, and retrieval of selected sample data by authorized persons and organizations. This System Architecture document is the aggregation of the DMR P+ methodology project management deliverables. Together they represent a description of the project and its plan through four Releases, corresponding to the definition and prioritization of requirements defined by the user

  12. Proposed radioactive liquid effluent monitoring requirements at the Savannah River Site

    International Nuclear Information System (INIS)

    Jannik, G.T.; Carlton, W.H.; Blunt, B.C.

    1994-01-01

    Clear regulatory guidance exists for structuring a radiological air monitoring program, however, there is no parallel guidance for radiological liquid monitoring. For Department of Energy (DOE) facilities, there are no existing applicable federal regulations, DOE orders, or DOE guidance documents that specify at what levels continuous monitoring, continuous sampling, or periodic confirmatory measurements of radioactive liquid effluents must be made. In order to bridge this gap and to technically justify and document liquid effluent monitoring decisions at DOE's Savannah River Site, Westinghouse Savannah River Company has proposed that a graded, dose-based approach be established, in conjunction with limits on facility radionuclide inventories, to determine the monitoring and sampling criteria to be applied at each potential liquid radioactive effluent point. The graded approach would be similar to--and a conservative extension of--the existing, agreed-upon SRS/EPA-IV airborne effluent monitoring approach documented in WSRC's NESHAP Quality Assurance Project Plan. The limits on facility radionuclide inventories are based on--and are a conservative extension of--the 10 CFR 834, 10 CFR 20, and SCR 61-63 annual limits on discharges to sanitary sewers. Used in conjunction with each other, the recommended source category criteria levels and facility radionuclide inventories would allow for the best utilization of resources and provide consistent, technically justifiable determinations of radioactive liquid effluent monitoring requirements

  13. Radiation treatment of gaseous and liquid effluents for contaminant removal. Proceedings of a technical meeting

    International Nuclear Information System (INIS)

    2005-12-01

    The Technical Meeting on Radiation Processing of Gaseous and Liquid Effluents conducted in Sofia, Bulgaria, 7-10 September 2004, discussed and evaluated issues related to the status and future trends in radiation application for environmental protection. Five experts from Bulgaria, India, the Republic of Korea, Poland, and the United States of America were invited to provide their experiences in this field. Twenty cost-free participants and observers - from Bulgaria, India, Lithuania, Poland and Ukraine -joined the meeting, and 15 papers in total were presented. Research and development in radiation processing of gaseous and liquid effluents is undertaken in three fields: electron beam flue gas treatment (SO x and NO x removal), wastewater purification and sewage sludge sterilization. Wastewater or sludge treatment and flue gas purification all differ from technological points of view, but they are common services and applications of environmental radiation technology applications, based mostly on electron accelerators. The technical meeting discussed new development in the field of radiation applications in environmental service, especially the status and prospects of radiation processing of gaseous and liquid effluents. Progress in the field of electron accelerators and gamma sources is crucial for routine application of the technology. Cost reduction and improvement of technical reliability are substantial especially for high power of accelerators and high activity of the sources needed for environmental applications. Environmental applications were carefully reviewed in accordance with the existing regulations and state of the art knowledge. The comparison with conventional commercial technologies was addressed as well. In flue gas treatment, applicability of the technology using different fossil fuels (coal, lignite, oil, etc.) was reviewed. The elaborated materials cover the technical and economical evaluation of the technologies. The possible applications of

  14. Technical treatment options for the mill effluents of the Los Gigantes Complex

    International Nuclear Information System (INIS)

    Asenjo, A.R.

    2002-01-01

    The Mining/Milling Los Gigantes Complex is located in Cordoba Province, about 100 km to the West of the capital city. The uranium mining and milling activities have been carried out during the period between 1980 and 1990. As result of those activities, mine wastes, low grade ore, sludge, heap leach wastes and liquid effluents have been accumulated in the site. At present, the National Atomic Energy Commission of Argentina is developing the Remediation Project of the site. Within the frame of this Project it is necessary to define the liquid effluent treatment methodology of the liquids accumulated in a pond in order to achieve the proper quality to be released to the environment, according with the national and provincial regulations. In this paper several liquid treatment methods are described. These methods were also developed at the lab scale. Among these we can mention hot and cool alcalinization with barium chloride addition and ion exchange resins treatments. Also a pilot scale assay has been done in the site (about 450 m 3 ) in order to verify the obtained lab scale results. Nevertheless that other assays are yet under developing, the obtained results are reported. (author)

  15. Water feed and effluent treatment for hydrogen sulfide-water system

    International Nuclear Information System (INIS)

    Spevack, J.S.

    1981-01-01

    This invention provides a feed and effluent treatment system for improving the recovery of a gas (e.g. H 2 S) from solution in a liquid (e.g. water) when the liquid also contains dissolved nonvolatile components (e.g. the salts of sea water) at low temperatures. In a gas/liquid contact process in which the gas is at least partially soluble in the liquid, a portion of the liquid is extracted after it passes through a hot zone, the pressure of the liquid is reduced by flashing it through pressure reduction means to remove a portion of the dissolved gas, and the gas thus recovered is returned to the process

  16. Liquid effluent Sampling and Analysis Plan (SAP) implementation summary report

    International Nuclear Information System (INIS)

    Lueck, K.J.

    1995-01-01

    This report summarizes liquid effluent analytical data collected during the Sampling and Analysis Plan (SAP) Implementation Program, evaluates whether or not the sampling performed meets the requirements of the individual SAPs, compares the results to the WAC 173-200 Ground Water Quality Standards. Presented in the report are results from liquid effluent samples collected (1992-1994) from 18 of the 22 streams identified in the Consent Order (No. DE 91NM-177) requiring SAPs

  17. Elimination of slightly radioactive liquid effluent by dilution. Its consequences (1960); Elimination par dilution d'effluents liquides faiblement radioactifs. Leurs consequences (1960)

    Energy Technology Data Exchange (ETDEWEB)

    Bovard, P; Candillon, C [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    Nuclear centres often have to solve problems raised by the elimination of large volumes of slightly radioactive liquid effluent. As things stand at present, the method usually adopted consists in expelling this effluent into the main water system in order to dilute it to a maximum, and thus to lower its radioactive isotope concentration to below the norms imposed by the Public Health Service. This technique requires systematic checking of the water system and its dependences, and demands a thorough knowledge of adsorption and fixation processes. (author) [French] Les centres nucleaires ont frequemment a resoudre des problemes poses par l'elimination de volumes importants d'effluents liquides faiblement radioactifs. Dans l'etat actuel des choses, la solution la plus utilisee consiste a rejeter ces effluents dans le reseau hydrographique de maniere a les diluer au maximum et abaisser ainsi leurs teneurs en isotopes radioactifs au-dessous des normes imposees par la Sante Publique. Cette technique necessite un controle systematique du reseau et de ses dependances et demande une connaissance approfondie des processus d'adsorption et de fixation. (auteur)

  18. LIQUID EFFLUENT RETENTION FACILITY (LERF) BASIN 42 STUDIES

    International Nuclear Information System (INIS)

    DUNCAN JB

    2004-01-01

    This report documents laboratory results obtained under test plan RPP-21533 for samples submitted by the Effluent Treatment Facility (ETF) from the Liquid Effluent Retention Facility (LERF) Basin 42 (Reference 1). The LERF Basin 42 contains process condensate (PC) from the 242-A Evaporator and landfill leachate. The ETF processes one PC campaign approximately every 12 to 18 months. A typical PC campaign volume can range from 1.5 to 2.5 million gallons. During the September 2003 ETF Basin 42 processing campaign, a recurring problem with 'gelatinous buildup' on the outlet filters from 60A-TK-I (surge tank) was observed (Figure 1). This buildup appeared on the filters after the contents of the surge tank were adjusted to a pH of between 5 and 6 using sulfuric acid. Biological activity in the PC feed was suspected to be the cause of the gelatinous material. Due to this buildup, the filters (10 (micro)m CUNO) required daily change out to maintain process throughput

  19. LIQUID EFFLUENT RETENTION FACILITY (LERF) BASIN 42 STUDIES

    Energy Technology Data Exchange (ETDEWEB)

    DUNCAN JB

    2004-10-29

    This report documents laboratory results obtained under test plan RPP-21533 for samples submitted by the Effluent Treatment Facility (ETF) from the Liquid Effluent Retention Facility (LERF) Basin 42 (Reference 1). The LERF Basin 42 contains process condensate (PC) from the 242-A Evaporator and landfill leachate. The ETF processes one PC campaign approximately every 12 to 18 months. A typical PC campaign volume can range from 1.5 to 2.5 million gallons. During the September 2003 ETF Basin 42 processing campaign, a recurring problem with 'gelatinous buildup' on the outlet filters from 60A-TK-I (surge tank) was observed (Figure 1). This buildup appeared on the filters after the contents of the surge tank were adjusted to a pH of between 5 and 6 using sulfuric acid. Biological activity in the PC feed was suspected to be the cause of the gelatinous material. Due to this buildup, the filters (10 {micro}m CUNO) required daily change out to maintain process throughput.

  20. Optimizing Liquid Effluent Monitoring at a Large Nuclear Complex

    International Nuclear Information System (INIS)

    Chou, Charissa J.; Johnson, V.G.; Barnett, Brent B.; Olson, Phillip M.

    2003-01-01

    Monitoring data for a centralized effluent treatment and disposal facility at the Hanford Site, a defense nuclear complex undergoing cleanup and decommissioning in southeast Washington State, was evaluated to optimize liquid effluent monitoring efficiency. Wastewater from several facilities is collected and discharged to the ground at a common disposal site. The discharged water infiltrates through 60 m of soil column to the groundwater, which eventually flows into the Columbia River, the second largest river in the contiguous United States. Protection of this important natural resource is the major objective of both cleanup and groundwater and effluent monitoring activities at the Hanford Site. Four years of effluent data were evaluated for this study. More frequent sampling was conducted during the first year of operation to assess temporal variability in analyte concentrations, to determine operational factors contributing to waste stream variability and to assess the probability of exceeding permit limits. Subsequently, the study was updated which included evaluation of the sampling and analysis regime. It was concluded that the probability of exceeding permit limits was one in a million under normal operating conditions, sampling frequency could be reduced, and several analytes could be eliminated, while indicators could be substituted for more expensive analyses. Findings were used by the state regulatory agency to modify monitoring requirements for a new discharge permit. The primary focus of this paper is on the statistical approaches and rationale that led to the successful permit modification and to a more cost-effective effluent monitoring program

  1. Effluent treatment for nuclear thermal propulsion ground testing

    Science.gov (United States)

    Shipers, Larry R.

    1993-01-01

    The objectives are to define treatment functions, review concept options, discuss PIPET effluent treatment system (ETS), and outline future activities. The topics covered include the following: reactor exhaust; effluent treatment functions; effluent treatment categories; effluent treatment options; concept evaluation; PIPETS ETS envelope; PIPET effluent treatment concept; and future activities.

  2. Liquid effluent retention facility dangerous waste permit application

    International Nuclear Information System (INIS)

    1991-06-01

    This appendix to the Liquid Effluent Retention Facility Dangerous Waste Permit Application contains pumps, piping, leak detection systems, geomembranes, leachate collection systems, earthworks and floating cover systems

  3. Nuclide separation by hydrothermal treatment and ion exchange: a highly effective method for treatment of liquid effluents - 59217

    International Nuclear Information System (INIS)

    Braehler, Georg; Rieck, Ronald; Avramenko, V.A.; Sergienko, V.I.; Antonov, E.A.

    2012-01-01

    Liquid low level radioactive effluents, when solidified in e.g. cement matrix, contribute to a significant extent to the waste amount to be disposed of in final repositories. Accordingly, since many years scientists and engineers investigate processes to remove the radioactive nuclides selectively from the effluents, to split the raw solution into two separate fractions: a large fraction with activity concentrations below the limits for free release; and a small fraction, containing the activity in concentrated form on e. g. ion exchanger materials (ion exchange has proven to be the most promising method for such 'nuclide separation'). The challenge to be taken up is: When (and this is most often the case) the effluent contains organic materials and complexing agents, the formation of e. g. the 60-Co-EDTA complex prohibits its fixation to the ion exchangers. Accordingly the complexing agent needs to be removed or destroyed. The Institute for Chemistry of the Russian Academy of Sciences has applied the method of hydrothermal treatment (at elevated temperature and pressure, 200 deg. C, 200 bar), supported by Hydrogen Peroxide oxidation, to allow virtually complete removal of radioactive nuclides on inorganic ion exchangers. Pilot plants have been operated successfully in Russian power stations, and an operational plant has been designed. The method is being extended for an interesting and promising application: spent organic ion exchange resins, loaded up to the medium activity level, represent a serious disposal problem. With the hydrothermal process, in a process cycle, the activity can be stripped from the resins, the organic content is destroyed, and the activity is fixed on an inorganic absorber, well suited for final disposal. (authors)

  4. Method for the determination of carboxylic acids in industrial effluents using dispersive liquid-liquid microextraction with injection port derivatization gas chromatography-mass spectrometry.

    Science.gov (United States)

    Makoś, Patrycja; Fernandes, Andre; Boczkaj, Grzegorz

    2017-09-29

    The paper presents a new method for the determination of 15 carboxylic acids in samples of postoxidative effluents from the production of petroleum bitumens using ion-pair dispersive liquid-liquid microextraction and gas chromatography coupled to mass spectrometry with injection port derivatization. Several parameters related to the extraction and derivatization efficiency were optimized. Under optimized experimental conditions, the obtained limit of detection and quantification ranged from 0.0069 to 1.12μg/mL and 0.014 to 2.24μg/mL, respectively. The precision (RSD ranged 1.29-6.42%) and recovery (69.43-125.79%) were satisfactory. Nine carboxylic acids at concentrations ranging from 0.10μg/mL to 15.06μg/mL were determined in the raw wastewater and in samples of effluents treated by various oxidation methods. The studies revealed a substantial increase of concentration of benzoic acids, in samples of wastewater after treatment, which confirms the need of carboxylic acids monitoring during industrial effluent treatment processes. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Biological treatment of the liquid effluents of a paper industry

    International Nuclear Information System (INIS)

    Mejia, Juan Felipe; Ramirez, Gladys Eugenia; Arias Zabala, Mario

    2001-01-01

    The objective of this paper is to determine the effect of the microorganisms Candida utilis and Candida tropicalis in the reduction of the chemical oxygen demand (COD) of the liquid effluents of a producing factory of paper kraft type, by means of fermentations made to pH of 5 and a 30 centigrade degrees during 6 days. The biological processing is preceded by a physicochemical process of directed acidulation to reduce pH of the effluent (liquor black) from its initial value, of approximately 13, to 5, in order to it is adapted for the growth of yeast. In this process, which forms precipitated, that is necessary to eliminate by centrifugation and filtration to facilitate the growth of the microorganisms, with is obtained one first removal of the COD of the order of 70 %. With the biological processing obtains for both yeasts a percentage of removal of 45 -50% of the COD surplus. The total removal of the COD, that is to say, obtained with the pre-cure and the fermentation it is of the order of 84% for the yeast. Additionally the possibility studied of implementing some complementary procedures to the biological processing, with a view to obtaining greater growth of yeast in the black liquor and thus obtaining additional reductions in the OCD of the same one

  6. Monitoring of low-level radioactive liquid effluent in Tokai reprocessing plant

    International Nuclear Information System (INIS)

    Mizutani, Tomoko; Koarashi, Jun; Takeishi, Minoru

    2009-01-01

    The Tokai reprocessing plant (TRP), the first reprocessing plant in Japan, has discharged low-level liquid wastes to the Pacific Ocean since the start of its operation in 1977. We have performed liquid effluent monitoring to realize an appropriate radioactive discharge control. Comparing simple and rapid analytical methods with labor-intensive radiochemical analyses demonstrated that the gross-alpha and gross-beta activities agreed well with the total activities of plutonium isotopes ( 238 Pu and 239+240 Pu) and major beta emitters (e.g., 90 Sr and 137 Cs), respectively. The records of the radioactive liquid discharge from the TRP showed that the normalized discharges of all nuclides, except for 3 H, were three or four orders of magnitude lower than those from the Sellafield and La Hague reprocessing plants. This was probably due to the installation of multistage evaporators in the liquid waste treatment process in 1980. The annual public doses for a hypothetical person were estimated to be less than 0.2 μSv y -1 from the aquatic pathway. Plutonium radioactivity ratios ( 238 Pu/ 239+240 Pu) of liquid effluents were determined to be 1.3-3.7, while those of the seabed sediment samples collected around the discharge point were 0.003-0.059, indicating no remarkable accumulation of plutonium in the regional aquatic environment. Thus, we concluded that there were no significant radiological effects on the public and the aquatic environment during the past 30-year operation of the TRP. (author)

  7. Treatment of liquid effluents from uranium analytical method 'DAVIES & GRAY' by electrodialysis and electrodialysis reactive tests

    International Nuclear Information System (INIS)

    Zuniga Alvear, Karina Andrea

    2014-01-01

    This work describes the process which produces liquid waste coming from the chemical analysis laboratory of the Chilean Nuclear Energy Commission (CCHEN), from the analytical technique called 'Davies and Gray' and their further treatment, using electro dialysis (ED) and reactive electro dialysis (RED), in order to achieve lower uranium contents in solution. The contamination in water is a big problem, since there are many places in the world where is limited. For these reasons new treatments must be done, and the ion-selective membrane has opened a new path for these processes. The radioactive liquid waste have lots of other restrictions in their final disposal, which difficult even more the water recovery, because the law has very strict security margins with respect to these ones. In the case of liquid waste containing uranium, the concern increases, because being the uranium a radioactive element has it has to be lowered at its maximum, or eliminated directly, in order to avoid any kind of contamination. There exist national regulations and international recommendations. They have stipulated the correct management and disposal for radioactive waste. These can come from any uranium production process. In any of these, the liquid waste contains certain uranium content, which after the end of the process; the discarded waste must go through a conditioning and cleaning process for its afterward liberation or recycling. In this study, it was tested the electro dialysis as a radioactive waste treatment, only uranium containing waste coming from the chemical analysis laboratory in CCHEN. The electro dialysis process has a direct competition with other separation process, such as distillation, ionic exchange, and reverse osmosis, among others. The classic electro dialysis has been developed during the 50's, and until today, there has been different version, as inverse, reactive, reversible. The unidirectional and reactive electro dialysis will be the

  8. Suspended solids in liquid effluents

    International Nuclear Information System (INIS)

    McGrath, J.J.

    1988-06-01

    An international literature review and telephone mail survey was conducted with respect to technical and regulatory aspects of suspended solids in radioactive liquid wastes from nuclear power stations. Results of the survey are summarized and show that suspended solids are an important component of some waste streams. The data available, while limited, show these solids to be associated largely with corrosion products. The solids are highly variable in quantity, size and composition. Filtration is commonly applied for their removal from liquid effluents and is effective. Complex interactions with receiving waters can result in physical/chemical changes of released radionuclides and these phenomena have been seen as reason for not applying regulatory controls based on suspended solids content. 340 refs

  9. Physico-chemical treatment of coke plant effluents for control of water pollution in India

    Energy Technology Data Exchange (ETDEWEB)

    Ghose, M.K. [Indian School of Mines, Dhanbad (India). Center of Mining Environmental

    2002-01-01

    Coal carbonizing industries in India are important and are growing every year. Large quantities of liquid effluents produced in this industry contain a large amount of suspended solids, high biochemical oxygen demand (BOD), chemical oxygen demand (COD), phenols, ammonia and other toxic substances, which are causing serious surface water pollution in the area. There is a large number of coke plants in the vicinity of Jharia Coal Field (JCF). The working principle of a coke plant and the effluents produced is described. One large coke plant was chosen to evaluate characteristics of the effluent and to suggest a proper treatment method. Present effluent treatment system was found to be inadequate and a large quantity of a very good quality coke breeze is being lost, which is also causing siltation on the riverbed in addition to surface water pollution. Physico-chemical treatment has been considered as a suitable option for the treatment of coke plant effluents. A scheme has been proposed for the treatment, which can be suitably adopted for the recycling, reuse or safe disposal of the treated effluent. Various unit process and unit operations are discussed. The process may be useful on industrial scale for various sites so as to maintain a clean environment.

  10. Systems engineering implementation plan for the liquid effluents services program

    International Nuclear Information System (INIS)

    Lowe, S.S.

    1995-01-01

    A graded approach is being taken by the Liquid Effluents Services Program in implementing systems engineering because of the advanced state of the program. The approach is cost-effective and takes credit for related work already completed, yet retains the benefits of systems engineering. This plan describes how the Liquid Effluents Services Program will implement systems engineering so there is a common understanding. Systems engineering work to be performed and the products of that work are identified. The relation to the current planning process and integration with the sitewide systems engineering effort is described

  11. Liquid effluent/Hanford Environmental compliance FY 1995 Multi-Year Program Plan/Fiscal Year Work Plan, WBS 1.2.2.1 and 1.2.2.2

    Energy Technology Data Exchange (ETDEWEB)

    1994-09-01

    This document details the program effort to eliminate the use of the soil column for liquid effluent treatment and to manage current and future liquid effluent streams at the Hanford Site, in a safe responsible cost effective and legally compliant mannger. This should be achieved through planning, public and stakeholder interaction, definition of requiremtns for generators, and provision of timely treatment, stroage, disposal capability, and waste minimization of waste streams.

  12. Liquid effluent/Hanford Environmental compliance FY 1995 Multi-Year Program Plan/Fiscal Year Work Plan, WBS 1.2.2.1 and 1.2.2.2

    International Nuclear Information System (INIS)

    1994-09-01

    This document details the program effort to eliminate the use of the soil column for liquid effluent treatment and to manage current and future liquid effluent streams at the Hanford Site, in a safe responsible cost effective and legally compliant mannger. This should be achieved through planning, public and stakeholder interaction, definition of requiremtns for generators, and provision of timely treatment, stroage, disposal capability, and waste minimization of waste streams

  13. Chemical processing of liquid effluents in reprocessing plants: experience gained in France

    International Nuclear Information System (INIS)

    Fernandez, N.; Pottier, P.; Taillard, D.

    1977-01-01

    The radionuclides present in radioactive liquid effluents are precipitated for two purposes, viz: 1) to reduce the radioactivity to a level at which the liquids may be discharged; 2) to concentrate the radioactive compounds in the smallest possible volume for storage. The scientific principles of the radionuclide precipitation process are reviewed in the first part, which covers the solubility product, adsorption onto the surface of the precipitates, co-precipitation by isomorphism, ion-exchange on precipitates, etc. The paper goes on to discuss flocculation techniques, flocculation monitoring (zeta potential etc.) and methods of separating the solid and liquid phases. The specific methods for precipitating the main radionuclides are then described, with special reference to Sr, Cs, Ru, Co and Sb. The synergism of certain methods of precipitation is also discussed. The main part of the paper concerns the application of chemical processes for purifying low and medium active effluents in the Marcoule and La Hague centres. Particular emphasis is placed on the development of the processes used and the improvement of performance. Lastly, the paper discusses the possibilities offered in final treatment in such a way as to determine the limits to the effectiveness of the chemical processes. (orig.) [de

  14. Liquid Effluent Monitoring Information System test plans releases 2.0 and 3.0

    International Nuclear Information System (INIS)

    Guettler, D.A.

    1995-01-01

    The Liquid Effluent Monitoring Information System (LEMIS) is being developed as the organized information repository facility in support of the liquid effluent monitoring requirements of the Tri-Party Agreement. It is necessary to provide an automated repository into which the results from liquid effluent sampling will be placed. This repository must provide for effective retention, review, and retrieval of selected sample data by authorized persons and organizations. This System Architecture document is the aggregation of the DMR P+ methodology project management deliverables. Together they represent a description of the project and its plan through four Releases, corresponding to the definition and prioritization of requirements defined by the user

  15. Assessment of options for the treatment of Sizewell PWR liquid effluent

    International Nuclear Information System (INIS)

    Hornby, J.; Allam, J.; Knibbs, R.H.

    1992-01-01

    This report describes the origins of PWR liquid waste streams, their composition and rates of arising. Data has been collected from operational PWRs and estimates obtained for Sizewell B PWR liquid waste streams. Current liquid waste treatment practices are reviewed and assessments made of established and novel treatment techniques which could be applicable to Sizewell B. A short list of treatment options is given and recommendations are made relating to established treatment technologies suitable for Sizewell B and also to development work on more novel treatments which could lead to a reduction in waste disposal volumes. (author)

  16. Decentralised wastewater treatment effluent fertigation: preliminary ...

    African Journals Online (AJOL)

    Decentralised wastewater treatment effluent fertigation: preliminary technical assessment. ... living in informal settlements with the effluent produced being used on agricultural land. ... Banana and taro required 3 514 mm of irrigation effluent.

  17. Operational experience of gaseous effluent treatment at the Eurochemic reprocessing plant

    International Nuclear Information System (INIS)

    Osipenco, A.; Detilleux, E.

    1977-01-01

    The EUROCHEMIC fuel reprocessing plant applies the PUREX flow sheet. Two particular features of the plant influence gaseous and liquid effluents: chemical decanning and the ability to process a wide range of fuels, uranium metal or oxide, having an initial enrichment typical of power reactors (up to 5%) or material testing reactors (up to 93%). The ventilation circuits, treatment plant and monitoring equipment for gaseous releases are briefly described. No retention facilities for rare gases, tritium, or carbon-14 are provided. The releases are monitored for krypton-85, iodine-131, alpha and beta-gamma aerosols and tritium. Between 1966 and 1974 the plant processes about 200 tonnes of power reactor fuel, from which about 0.7 tonnes of plutonium and 1.5 tonnes of highly enriched uranium were separated. The most important points in the operation of the gas cleaning equipment are indicated: efficiency, operational reliability, incidents, etc.. Actual discharges as measured are compared with the limits set in the operation licence. Using the atmospheric diffusion coefficients, the dose commitment is estimated. The low level liquid effluents are passed, after neutralization, to the treatment plant of the Belgian nuclear center CEN/SCK. However, if the activity exceeds the limit set by the CEN/SCK, the effluents are concentrated by evaporation and stored on the EUROCHEMIC site. (orig.) [de

  18. Optimizing liquid effluent monitoring at a large nuclear complex.

    Science.gov (United States)

    Chou, Charissa J; Barnett, D Brent; Johnson, Vernon G; Olson, Phil M

    2003-12-01

    Effluent monitoring typically requires a large number of analytes and samples during the initial or startup phase of a facility. Once a baseline is established, the analyte list and sampling frequency may be reduced. Although there is a large body of literature relevant to the initial design, few, if any, published papers exist on updating established effluent monitoring programs. This paper statistically evaluates four years of baseline data to optimize the liquid effluent monitoring efficiency of a centralized waste treatment and disposal facility at a large defense nuclear complex. Specific objectives were to: (1) assess temporal variability in analyte concentrations, (2) determine operational factors contributing to waste stream variability, (3) assess the probability of exceeding permit limits, and (4) streamline the sampling and analysis regime. Results indicated that the probability of exceeding permit limits was one in a million under normal facility operating conditions, sampling frequency could be reduced, and several analytes could be eliminated. Furthermore, indicators such as gross alpha and gross beta measurements could be used in lieu of more expensive specific isotopic analyses (radium, cesium-137, and strontium-90) for routine monitoring. Study results were used by the state regulatory agency to modify monitoring requirements for a new discharge permit, resulting in an annual cost savings of US dollars 223,000. This case study demonstrates that statistical evaluation of effluent contaminant variability coupled with process knowledge can help plant managers and regulators streamline analyte lists and sampling frequencies based on detection history and environmental risk.

  19. Treatment of liquid effluents from an ammonia/urea/sulphur plant

    Energy Technology Data Exchange (ETDEWEB)

    Padula, R.C.; Amabal, S.P.

    1979-01-01

    The effluent treatment processes planned for a new 1500 ton/day urea, 1200 ton/day ammonia plant in Brazil, based on the two-stage reaction of ammonia and carbon dioxide to form urea and on the catalytic hydrogenation of nitrogen to ammonia, will include the steps of equalization, flocculation, flotation, nitrification, sedimentation, denitrification, rapid aeration, further settlement, filtration, and discharge to a river. Sludge will be chemically conditioned as needed, and will be thickened, filtered, and disposed of by land application. There will be considerable recycling of nutrients.

  20. Request for modification of 200 Area effluent treatment facility final delisting

    International Nuclear Information System (INIS)

    Bowman, R.C.

    1998-01-01

    A Delisting Petition submitted to the U.S. Environmental Protection Agency in August 1993 addressed effluent to be generated at the 200 Area Effluent Treatment Facility from treating Hanford Facility waste streams. This Delisting Petition requested that 71.9 million liters per year of treated effluent, bearing the designation 'F001' through 'F005', and/or 'F039' that is derived from 'F001' through 'F005' waste, be delisted. On June 13, 1995, the U.S. Environmental Protection Agency published the final rule (Final Delisting), which formally excluded 71.9 million liters per year of 200 Area Effluent Treatment Facility effluent from ''being listed as hazardous wastes'' (60 FR 31115 now promulgated in 40 CFR 261). Given the limited scope, it is necessary to request a modification of the Final Delisting to address the management of a more diverse multi-source leachate (F039) at the 200 Area Effluent Treatment Facility. From past operations and current cleanup activities on the Hanford Facility, a considerable amount of both liquid and solid Resource Conservation and Recovery Act of 1976 regulated mixed waste has been and continues to be generated. Ultimately this waste will be treated as necessary to meet the Resource Conservation and Recovery Act Land Disposal Restrictions. The disposal of this waste will be in Resource Conservation and Recovery Act--compliant permitted lined trenches equipped with leachate collection systems. These operations will result in the generation of what is referred to as multi-source leachate. This newly generated waste will receive the listed waste designation of F039. This waste also must be managed in compliance with the provisions of the Resource Conservation and Recovery Act

  1. Method for the simultaneous determination of monoaromatic and polycyclic aromatic hydrocarbons in industrial effluents using dispersive liquid-liquid microextraction with gas chromatography-mass spectrometry.

    Science.gov (United States)

    Makoś, Patrycja; Fernandes, André; Boczkaj, Grzegorz

    2018-02-23

    We present a new method for simultaneous determination of 22 monoaromatic and polycyclic aromatic hydrocarbons in postoxidative effluents from the production of petroleum bitumen using dispersive liquid-liquid microextraction coupled to gas chromatography and mass spectrometry. The eight extraction parameters including the type and volume of extraction and disperser solvent, pH, salting out effect, extraction, and centrifugation time were optimized. The low detection limit ranging from 0.36 to 28 μg/L, limit of quantitation (1.1-84 μg/L), good reproducibility, and wide linear ranges, as well as the recoveries ranging from 71.74 to 114.67% revealed that the new method allows the determination of aromatic hydrocarbons at low concentration levels in industrial effluents having a very complex composition. The developed method was applied to the determination of content of mono- and polycyclic aromatic hydrocarbons in samples of raw postoxidative effluents in which 15 compounds were identified at concentrations ranging from 1.21 to 1017.0 μg/L as well as in effluents after chemical treatment. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Biotransformation of chromium (VI) in liquid effluents by resistant bacteria isolated from the Matanza-Riachuelo basin, in Argentina.

    Science.gov (United States)

    González, Ana Julieta; Caimán, Carolina; Gorino, Natalia; Fortunato, María Susana; Radice, Marcela; Gómez, Carlos; Mujica, Carolina; Marquina, Lorena; Gallego, Alfredo; Korol, Sonia Edith

    2017-10-10

    The aims of this investigation were to evaluate the bacterial resistance to zinc, copper, chromium (VI) and lead in surface water streams from Buenos Aires, Argentina; to select a chromium-resistant strain able to remove the metal in batch process and to evaluate the potential of this strain to remove chromium (VI) in liquid effluents. Bacterial resistance to the metals was evaluated by determining the minimal inhibitory concentration. The kinetic of chromium (VI) removal by one of the resistant strains was studied in nutrient broth with 50 and 100 mg L -1 of the metal, as well as an effluent from an electroplating industry. High resistance to all the metals under study was observed in the bacterial communities of the Matanza-Riachuelo basin. A chromium-resistant strain was isolated and identified as Microbacterium sp. It was able to remove 50 and 100 mg L -1 of Cr (VI) in 36 and 66 h respectively, with efficiency higher than 99%. Experiments with liquid effluents showed the ability of the strain to transform 150 mg L -1 of the metal in 84 h, with efficiency higher than 99%. These results show the potential of this native strain for the treatment of liquid effluents that contain chromium (VI).

  3. Treatment and processing of the effluents and wastes (other than fuel) produced by a 900 MWe nuclear power plant

    International Nuclear Information System (INIS)

    Giraud

    1983-01-01

    Effluents produced by a 900 MWe power plant, are of three sorts: gaseous, liquid and solid. According to their nature, effluents are either released or stored for decaying before being released to the atmosphere. The non-contaminated reactor coolant effluents are purified (filtration, gas stripping) and treated by evaporation for reuse. Depending upon their radioactive level, liquid waste is either treated by evaporation or discharged after filtration. Solid waste issuing from previous treatments (concentrates, resins, filters) is processed in concrete drums using an encapsulation process. The concrete drum provides biological self-protection consistent with the national and international regulations pertaining to the transport of radioactive substance. Finally, the various low-level radioactive solid waste collected throughout the plant, is compacted into metal drums. Annual estimates of the quantity of effluents (gaseous, liquid) released in the environment and the number of drums (concrete, metal) produced by the plant figure in the conclusion

  4. Radiation treatment of sewage effluent, (2)

    International Nuclear Information System (INIS)

    Sawai, Teruko; Sekiguchi, Masayuki; Sawai, Takeshi; Shimokawa, Toshinari; Tanabe, Hiroko

    1991-01-01

    The water demand of the past several years has increased rapidly. Recycling of municipal waste water is an effective mean of coping with the water shortage in Tokyo. We studied the radiation treatment method of further purification of the effluent from sewage treatment plants. By gamma irradiation the refractory organic substances in the effluent were decomposed and the COD values decreased with increasing dose. The high molecular weight components in the effluent were degraded to lower molecular weight substances and were decomposed finally to carbon dioxide. In this paper we studied on the fading color and the reducing of order of sewage effluent. (author)

  5. Performance of Hybrid Photocatalytic-Ceramic Membrane System for the Treatment of Secondary Effluent.

    Science.gov (United States)

    Song, Lili; Zhu, Bo; Gray, Stephen; Duke, Mikel; Muthukumaran, Shobha

    2017-03-28

    Evaluation of an advanced wastewater treatment system that combines photocatalysis with ceramic membrane filtration for the treatment of secondary effluent was undertaken. The results showed that, after photocatalysis and ceramic membrane filtration, the removal of dissolved organic carbon and UV 254 was 60% and 54%, respectively, at a concentration of 4 g/L of TiO₂. Dissolved organic matter (DOM) present in the secondary effluent was characterised with a liquid chromatography-organic carbon detector (LC-OCD) technique. The results showed low removal of humics, building blocks, the other oxidation by-products and no removal of biopolymers after TiO₂/UV photocatalytic treatment. This suggested that the radical non-selective oxidation mechanisms of TiO₂/UV process resulted in secondary effluent in which all of the DOM fractions were present. However, the hybrid system was effective for removing biopolymers with the exception of low molecular weight (LMW) compounds acids, which accumulated from the beginning of the reaction. In addition, monitoring of the DOM fractions with LC-OCD analysis demonstrated that the reduction of the effluent aromaticity was not firmly correlated with the removal of humic substances for the combined processes.

  6. Liquid Effluent Monitoring Program at the Pacific Northwest Laboratory

    International Nuclear Information System (INIS)

    Ballinger, M.Y.

    1995-05-01

    Pacific Northwest Laboratory (PNL) is conducting a program to monitor the waste water from PNL-operated research and development facilities on the Hanford Site. The purpose of the program is to collect data to assess administrative controls and to determine whether discharges to the process sewer meet sewer criteria. Samples have been collected on a regular basis from the major PNL facilities on the Hanford Site since March 1994. A broad range of analyses has been performed to determine the primary constituents in the liquid effluent. The sampling program is briefly summarized in the paper. Continuous monitoring of pH, conductivity, and flow also provides data on the liquid effluent streams. In addition to sampling and monitoring, the program is evaluating the dynamics of the waste stream with dye studies and is evaluating the use of newer technologies for potential deployment in future sampling/monitoring efforts. Information collected to date has been valuable in determining sources of constituents that may be higher than the Waste Acceptance Criteria (WAC) for the Treated Effluent Disposal Facility (TEDF). This facility treats the waste streams before discharge to the Columbia River

  7. Improved technique for in situ measurement of radioactivity in liquid effluents

    International Nuclear Information System (INIS)

    Balasundar, S.; Jose, M.T.; Ravi, T.; Sundaram, V.M.; Raghunath, V.M.

    1993-01-01

    As a pre-requisite for handling and disposal of radioactive liquid effluents, they should be categorized according to their chemical nature and the type and level of radioactivity. A continuous monitoring of these effluents is necessary to assess the discharged activity and to detect any unusually large increase in the activity level. It may also be required to assess the beta, gamma specific activities in the effluents independently instead of just combined beta-gamma activity as is generally done. (author). 1 ref., 2 tabs

  8. Plant and soil modifications by continuous surface effluent application

    Energy Technology Data Exchange (ETDEWEB)

    Tedesco, M J; Levien, R [Rio Grande do Sul Univ., Porto Alegre, RS (Brazil). Dept. of Solos; Mohrdieck, F G; Rodrigues, N R [CORSAN-SITEL, Triunfo, RS (Brazil). Polo Petroquimico do Sul. Dept. de Operacao e Manutencao; Flores, A I.P.

    1994-12-31

    In order to study the effects on soil and plants of the liquid effluent generated by a the Integrated Liquid Effluent Treatment System of a large Brazilian petrochemical complex, a field study was conducted in four areas which received the effluent and compared to control sites. This work presents some results of this study. 12 refs., 1 fig., 3 tabs.

  9. Plant and soil modifications by continuous surface effluent application

    Energy Technology Data Exchange (ETDEWEB)

    Tedesco, M.J.; Levien, R. [Rio Grande do Sul Univ., Porto Alegre, RS (Brazil). Dept. of Solos; Mohrdieck, F.G.; Rodrigues, N.R. [CORSAN-SITEL, Triunfo, RS (Brazil). Polo Petroquimico do Sul. Dept. de Operacao e Manutencao; Flores, A.I.P.

    1993-12-31

    In order to study the effects on soil and plants of the liquid effluent generated by a the Integrated Liquid Effluent Treatment System of a large Brazilian petrochemical complex, a field study was conducted in four areas which received the effluent and compared to control sites. This work presents some results of this study. 12 refs., 1 fig., 3 tabs.

  10. Design and development of effluent treatment plants for the Sellafield reprocessing factory

    International Nuclear Information System (INIS)

    Howden, M.

    1989-01-01

    The reprocessing of spent nuclear fuel has been carried out at Sellafield since the early 1950s. The storage of fuel in water filled ponds prior to reprocessing and the reprocessing operation itself results in the generation of a number of radioactive liquid effluents. The highly active liquors are stored in stainless steel tanks and will, with the commissioning of the Windscale Vitrification Plant, be converted into glass for long term storage and disposal. The medium and low active liquors are, after appropriate treatment, discharged to sea well below the Authorised Limits which are set by the appropriate Regulatory Bodies. Since 1960 these have been the Department of the Environment and the Ministry of Agriculture, Fisheries and Food. Even though the discharges have been well below the limits set, BNFL have for many years adopted a policy of reducing the levels of activity still further. Considerable progress has already been made, by changing reprocessing operations regimes but more importantly by the development and construction of specialised effluent treatment plants. Further reductions are, however, planned. Two major effluent treatment plants form the main basis of BNFL's policy to reduce activity discharges from Sellafield. The first, the Site Ion Exchange Effluent Plant, to treat storage pond water was brought into operation in 1985. The second, the enhanced Actinide Removal Plant to treat medium and low active effluents, is programmed to operate in 1992. (author)

  11. Effect of surface treatment of tailings on effluent quality

    International Nuclear Information System (INIS)

    Murray, D.R.

    1980-01-01

    Successful reclamation treatment, in preparation for long range abandonment of mining wastes, involves both surface treatment and water quality control containment of waste solids and liquid contaminants. This paper describes use of lysimeters containing 125 tonnes of tailings to determine the impact of gravel, sawdust, and vegetation as surface treatments on the quality and quantity of effluent produced from sulphide-containing uranium mill tailings. Over a five-year period these treatments were observed and compared with bare tailings where no surface addition was made. The treatments did not alter the effluent quality to a level acceptable to regulatory requirements. Surface treatments did not appear to affect the leaching of Ra-226, NH 4 and NO 3 . The concentration of Fe, SO 4 , Cu, Pb, and Al increased with the rise of acidity as the pH changed from pH 9.5 to pH 2 in four and one-half years. However the rate and extent of changes of some of these parameters vary with the treatment. The experimental results for the observed trends are presented with limited explanation. Original design problems and unexpected delays in tailing reactions have made firm conclusions impossible at this stage. These data, however, provide a base for further investigation and development of explanations and firm conclusions, as to the role of surface treatment in long-term waste abandonment

  12. Request for modification of 200 Area effluent treatment facility final delisting

    Energy Technology Data Exchange (ETDEWEB)

    BOWMAN, R.C.

    1998-11-19

    A Delisting Petition submitted to the U.S. Environmental Protection Agency in August 1993 addressed effluent to be generated at the 200 Area Effluent Treatment Facility from treating Hanford Facility waste streams. This Delisting Petition requested that 71.9 million liters per year of treated effluent, bearing the designation 'F001' through 'F005', and/or 'F039' that is derived from 'F001' through 'F005' waste, be delisted. On June 13, 1995, the U.S. Environmental Protection Agency published the final rule (Final Delisting), which formally excluded 71.9 million liters per year of 200 Area Effluent Treatment Facility effluent from ''being listed as hazardous wastes'' (60 FR 31115 now promulgated in 40 CFR 261). Given the limited scope, it is necessary to request a modification of the Final Delisting to address the management of a more diverse multi-source leachate (F039) at the 200 Area Effluent Treatment Facility. From past operations and current cleanup activities on the Hanford Facility, a considerable amount of both liquid and solid Resource Conservation and Recovery Act of 1976 regulated mixed waste has been and continues to be generated. Ultimately this waste will be treated as necessary to meet the Resource Conservation and Recovery Act Land Disposal Restrictions. The disposal of this waste will be in Resource Conservation and Recovery Act--compliant permitted lined trenches equipped with leachate collection systems. These operations will result in the generation of what is referred to as multi-source leachate. This newly generated waste will receive the listed waste designation of F039. This waste also must be managed in compliance with the provisions of the Resource Conservation and Recovery Act.

  13. TBP production plant effluent treatment process

    International Nuclear Information System (INIS)

    Sriniwas, C.; Sugilal, G.; Wattal, P.K.

    2004-06-01

    TBP production facility at Heavy Water Plant, Talcher generates about 2000 litres of effluent per 200 kg batch. The effluent is basically an aqueous solution containing dissolved and dispersed organics such as dibutyl phosphate, butanol etc. The effluent has high salinity, chemical oxygen demand (30-80 g/L) and pungent odour. It requires treatment before discharge. A chemical precipitation process using ferric chloride was developed for quantitative separation of organics from the aqueous part of the effluent. This process facilitates the discharge of the aqueous effluent. Results of the laboratory and bench scale experiments on actual effluent samples are presented in this report. (author)

  14. Treatability studies of alternative wastewaters for Metal Finishing Effluent Treatment Facility

    International Nuclear Information System (INIS)

    Wittry, D.M.; Martin, H.L.

    1994-01-01

    The 300-M Area Liquid Effluent Treatment Facility (LETF) of the Savannah River Site (SRS) is an end-of-pipe industrial wastewater treatment facility that uses precipitation and filtration, which is the EPA Best Available Technology economically achievable for a Metal Finishing and Aluminum Form Industries. Upon the completion of stored waste treatment, the LETF will be shut down, because production of nuclear materials for reactors stopped at the end of the Cold War. The economic use of the LETF for the treatment of alternative wastewater streams is being evaluated through laboratory bench-scale treatability studies

  15. Removal of active species from liquid effluent

    International Nuclear Information System (INIS)

    Blake, N.J.; Ritchie, S.

    1992-01-01

    Experimental and theoretical assessments were made of recirculating liquid membrane technology applied to the removal of active species from liquid effluent. Caesium and strontium were extracted from neutral, aqueous liquor by di-(2-ethylhexyl) phosphate in odourless kerosine and subsequently stripped by nitric acid. Flowrates to the membrane modules influenced the extraction and stripping mass transfer coefficients (MTC) for caesium, but not strontium. The acid strength of the strip solution affected the stripping MTC. When both ions were co-processed, caesium transfer was retarded. Potassium cobalt ferrocyanide and polyantimonic acid were used as adsorbers for caesium and strontium respectively in the strip loop. Caesium was more quickly adsorbed than strontium. A scale-up assessment of a recirculating liquid membrane was performed and compared to SIXEP at Sellafield. (author)

  16. Management of radioactive effluents from research Reactors and PHWRs

    International Nuclear Information System (INIS)

    Bodke, S.B.; Surender Kumar; Sinha, P.K.; Budhwar, R.K.; Raj, Kanwar

    2006-01-01

    Indian nuclear power programme is mainly based on pressurized heavy water reactors (PHWRs). In addition we have research reactors namely Apsara, CIRUS, Dhruva at Trombay. The operation and maintenance activities of these reactors generate radioactive liquid waste. These wastes require effective management so that the release of radioactivity to the environment is well within the authorized limits. India is self reliant in the design, erection, commissioning and operation of effluent management system for nuclear reactors. Segregation at source based on nature of effluents and radioactivity content is the first and foremost step in the over all management of liquid effluents. The effluents from the power reactors contain mainly activation products like 3 H. It also contains fission products like 137 Cs. Containment of these radionuclide along with 60 Co, 90 Sr, 131 I plays an important part in liquid waste management. Treatment processes for decontamination of these radionuclide include chemical treatment, ion exchange, evaporation etc. Effluents after treatment are monitored and discharged to the nearby water body after filtration and dilution. The concentrates from the processes are conditioned in cement matrix and disposed in Near Surface Disposal Facilities (NSDFs) co-located at each site. Some times large quantity of effluents with higher radioactivity concentration may get generated from the abnormal operation such as failure of heat exchangers. These effluents are handled on a campaign basis for which adequate storage capacity is provided. The treatment is given taking into consideration the required decontamination factor (DF), capacities of available treatment process, discharge limits and the availability of the dilution water. Similarly large quantities of effluents may get generated during fuel clad failure incident in reactors. In such situation, as in CIRUS large volume of effluent containing higher radioactivity are generated and are managed by delay

  17. Functional design criteria for project W-252, phase II liquid effluent treatment and disposal. Revision 2

    International Nuclear Information System (INIS)

    Hatch, C.E.

    1995-05-01

    This document is the Functional Design Criteria for Project W-252. Project W-252 provides the scope to provide BAT/AKART (best available technology...) to 200 Liquid Effluent Phase II streams (B-Plant). This revision (Rev. 2) incorporates a major descoping of the project. The descoping was done to reflect a combination of budget cutting measures allowed by a less stringent regulatory posture toward the Phase II streams

  18. New procedure for the control of the treatment of industrial effluents to remove volatile organosulfur compounds.

    Science.gov (United States)

    Boczkaj, Grzegorz; Makoś, Patrycja; Fernandes, André; Przyjazny, Andrzej

    2016-10-01

    We present a new procedure for the determination of volatile organosulfur compounds in samples of industrial effluents using dispersive liquid-liquid microextraction and gas chromatography with flame photometric detection. Initially, the extraction parameters were optimized. These included: type and volume of extraction solvent, volume of disperser solvent, salting out effect, pH, time and speed of centrifugation as well as extraction time. The procedure was validated for 30 compounds. The developed procedure has low detection limits of 0.0071-0.49 μg/L and a good precision (relative standard deviation values of 1.2-5.0 and 0.6-4.1% at concentrations of 1 and 10 μg/L, respectively). The procedure was used to determine the content of volatile organosulfur compounds in samples of effluents from the production of bitumens before and after chemical treatment, in which six compounds were identified, including 2-mercaptoethanol, thiophenol, thioanisole, dipropyl disulfide, 1-decanethiol, and phenyl isothiocyanate at concentrations ranging from 0.47 to 8.89 μg/L. Problems in the determination of organosulfur compounds related to considerable changes in composition of the effluents, increase in concentration of individual compounds and appearance of secondary pollutants during effluent treatment processes are also discussed. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. High-yield pulping effluent treatment technologies

    International Nuclear Information System (INIS)

    Su, W.X.; Hsieh, J.S.

    1993-03-01

    The objective of this report is to examine the high-yield (mechanical) pulp processes with respect to environmental issues affected by the discharge of their waste streams. Various statistics are given that support the view that high-yield pulping processes will have major growth in the US regions where pulp mills are located, and sites for projects in the development phase are indicated. Conventional and innovative effluent-treatment technologies applicable to these processes are reviewed. The different types of mechanical pulping or high-yield processes are explained, and the chemical additives are discussed. The important relationship between pulp yield and measure of BOD in the effluent is graphically presented. Effluent contaminants are identified, along with other important characteristics of the streams. Current and proposed environmental limitations specifically related to mechanical pulp production are reviewed. Conventional and innovative effluent-treatment technologies are discussed, along with their principle applications, uses, advantages, and disadvantages. Sludge management and disposal techniques become an intimate part of the treatment of waste streams. The conclusion is made that conventional technologies can successfully treat effluent streams under current waste-water discharge limitations, but these systems may not be adequate when stricter standards are imposed. At present, the most important issue in the treatment of pulp-mill waste is the management and disposal of the resultant sludge

  20. Determination of statin drugs in hospital effluent with dispersive liquid-liquid microextraction and quantification by liquid chromatography.

    Science.gov (United States)

    Martins, Ayrton F; Frank, Carla da S; Altissimo, Joseline; de Oliveira, Júlia A; da Silva, Daiane S; Reichert, Jaqueline F; Souza, Darliana M

    2017-08-24

    Statins are classified as being amongst the most prescribed agents for treating hypercholesterolaemia and preventing vascular diseases. In this study, a rapid and effective liquid chromatography method, assisted by diode array detection, was designed and validated for the simultaneous quantification of atorvastatin (ATO) and simvastatin (SIM) in hospital effluent samples. The solid phase extraction (SPE) of the analytes was optimized regarding sorbent material and pH, and the dispersive liquid-liquid microextraction (DLLME), in terms of pH, ionic strength, type and volume of extractor/dispersor solvents. The performance of both extraction procedures was evaluated in terms of linearity, quantification limits, accuracy (recovery %), precision and matrix effects for each analyte. The methods proved to be linear in the concentration range considered; the quantification limits were 0.45 µg L -1 for ATO and 0.75 µg L -1 for SIM; the matrix effect was almost absent in both methods and the average recoveries remained between 81.5-90.0%; and the RSD values were <20%. The validated methods were applied to the quantification of the statins in real samples of hospital effluent; the concentrations ranged from 18.8 µg L -1 to 35.3 µg L -1 for ATO, and from 30.3 µg L -1 to 38.5 µg L -1 for SIM. Since the calculated risk quotient was ≤192, the occurrence of ATO and SIM in hospital effluent poses a potential serious risk to human health and the aquatic ecosystem.

  1. Treatment of LL and ML liquid radwaste. The SGN experience

    International Nuclear Information System (INIS)

    Tchemitcheff, E.; Roux, P.

    1993-01-01

    SGN (Societe Generale pour les Techniques Nouvells) with considerable know-how and thirty years of feed-back in industrial management of liquid effluents from the entire French nuclear industry, has accordingly completed many low- and medium-level liquid radwaste treatment, relying on two major industrially proven technologies: evaporation and chemical coprecipitation. The low level and medium level radwaste in France and evaluated

  2. Optimal policies for activated sludge treatment systems with multi effluent stream generation

    Directory of Open Access Journals (Sweden)

    Gouveia R.

    2000-01-01

    Full Text Available Most industrial processes generate liquid waste, which requires treatment prior to disposal. These processes are divided into sectors that generate effluents with time dependent characteristics. Each sector sends the effluent to wastewater treatment plants through pumping-stations. In general, activated sludge is the most suitable treatment and consists of equalization, aeration and settling tanks. During the treatment, there is an increase in the mass of microorganisms, which needs to be removed. Sludge removal represents the major operating costs for wastewater treatment plants. The objective of this work is to propose an optimization model to minimize sludge generation using a superstructure in which the streams from pumping-stations can be sent to the equalization tank. In addition, the aeration tank is divided into cells that can be fed in series and parallel. The model relies on mass balances, kinetic equations, and the resulting Nonlinear Programming problem generates the best operational strategy for the system feed streams with a high substrate removal. Reductions of up to 30 % can be achieved with the proposed strategy maintened BOD efficiency removal upper than 98 %.

  3. Dosage of fission products in irradiated fuel treatment effluents (radio-chemical method); Dosage des produits de fission dans les effluents du traitement des combustibles irradies (methode radiochimique)

    Energy Technology Data Exchange (ETDEWEB)

    Auchapt, J [Commissariat a l' Energie Atomique, Marcoule (France). Centre d' Etudes Nucleaires

    1966-07-01

    The dosage methods presented here are applicable to relatively long-lived fission products present in the effluents resulting from irradiated fuel treatment processes (Sr - Cs - Ce - Zr - Nb - Ru - I). The methods are based on the same principle: - addition of a carrying-over agent - chemical separation over several purification stages, - determination of the chemical yield by calorimetry - counting of an aliquot liquid portion. (author) [French] Les methodes de dosage presentees concernent les produits de fission a vie relativement longue presents dans les effluents de traitement des combustibles irradies (Sr - Cs - Ce - Zr - Nb - Ru - I). Elles sont toutes basees sur le meme principe: - addition d'entraineur, - separation chimique en plusieurs stades de purification, - determination du rendement chimique par calorimetrie, - comptage d'une aliquote liquide. (auteur)

  4. Toxicity regulation of radioactive liquid waste effluent from CANDU stations - lessons from Ontario's MISA program

    International Nuclear Information System (INIS)

    Rodgers, D.W.

    2009-01-01

    Toxicity testing became an issue for Ontario's CANDU stations, when it was required under Ontario's MISA regulations for the Electricity Generation Sector. In initial tests, radioactive liquid waste (RLW) effluent was intermittently toxic to both rainbow trout and Daphnia. Significant differences in RLW toxicity were apparent among stations and contributing streams. Specific treatment systems were designed for three stations, with the fourth electing to use existing treatment systems. Stations now use a combination of chemical analysis and treatment to regulate RLW toxicity. Studies of Ontario CANDU stations provide a basis for minimizing costs and environmental effects of new nuclear stations. (author)

  5. Approach to the problem of liquid effluents in petrochemical plants; Abordagem do problema efluentes liquidos em plantas petroquimicas

    Energy Technology Data Exchange (ETDEWEB)

    Rios, Cordelia Alves [PROMON Engenharia SA, Rio de Janeiro, RJ (Brazil)

    1993-12-31

    It represents the typical example of petrochemical company that uses the responsible care. The company looks for solve the liquid effluent problems of its units at a complete view. First of all, they made a complete report of the environmental scenario through the operational conditions (it included the collect system, effluent treatment, etc.) and their connection with the environmental problems. In the following step was made the necessary changes to establish the effluents pollute level below the allowable levels and to avoid soil contamination. The company has made the modifications at the following systems:a closed system to collect and reprocess process drains; collect, transfer and retention of contaminated storm water; a stripper column and a solid removal system to treat contaminated water. (author) 2 figs.

  6. Approach to the problem of liquid effluents in petrochemical plants; Abordagem do problema efluentes liquidos em plantas petroquimicas

    Energy Technology Data Exchange (ETDEWEB)

    Rios, Cordelia Alves [PROMON Engenharia SA, Rio de Janeiro, RJ (Brazil)

    1992-12-31

    It represents the typical example of petrochemical company that uses the responsible care. The company looks for solve the liquid effluent problems of its units at a complete view. First of all, they made a complete report of the environmental scenario through the operational conditions (it included the collect system, effluent treatment, etc.) and their connection with the environmental problems. In the following step was made the necessary changes to establish the effluents pollute level below the allowable levels and to avoid soil contamination. The company has made the modifications at the following systems:a closed system to collect and reprocess process drains; collect, transfer and retention of contaminated storm water; a stripper column and a solid removal system to treat contaminated water. (author) 2 figs.

  7. Inorganic ion exchangers. Application to liquid effluent processing

    International Nuclear Information System (INIS)

    Dozol, M.

    1983-10-01

    Main inorganic ion exchangers used for radioactive liquid effluents presented in this report are: synthetic and natural zeolites, in titanium oxides, titanates, niobates, tantalates, zirconates, some insoluble salts of zirconium, molybdenum and tin, heteropolyacids and polyantimonic acid. Properties of these ion exchangers are described: structure, adsoption, radiation effects and thermal stability, application to waste processing, radioactive waste storage uranium and cesium 137 recovery are evoked [fr

  8. Risk-Based Radioactive Liquid Effluent Monitoring Requirements at the U. S. Department of Energy's Savannah River Site

    International Nuclear Information System (INIS)

    Jannik, G.T.

    2001-01-01

    For Department of Energy (DOE) facilities, clear regulatory guidance exists for structuring radiological air emissions monitoring programs. However, there are no parallel regulations for radiological liquid effluent monitoring programs. In order to bridge this gap and to technically justify liquid effluent monitoring decisions at DOE's Savannah River Site, a graded, risk-basked approach has been established to determine the monitoring and sampling criteria to be applied at each liquid discharge point

  9. Rancho Seco liquid effluent pathway aquatic and terrestrial dietary survey report

    International Nuclear Information System (INIS)

    Eagle, R.J.; Wong, K.M.; Noshkin, V.E.

    1984-01-01

    This report is a detailed summary of a survey conducted to identify all environmental pathways that may lead to any potential radiological dose to individuals utilizing aquatic and terrestrial components possibly contaminated with radionuclides contained in the liquid effluents that have been routinely discharged since 1980 to Clay Creek from the Rancho Seco Nuclear Generating Station. All land users and identified residents who obtain food from the creeks or use the creek water for irrigation or recreation were interviewed. Site specific usage parameters for the consumption of different food products and for direct exposure to individuals at downstream locations were identified and are discussed in this report. These usage parameters will be used with appropriate radionuclide concentration data to estimate radiological dose to man from the identified liquid effluent pathways

  10. Derived release limits for radionuclides in airborne and liquid effluents for the Whiteshell Nuclear Research Establishment and errata

    International Nuclear Information System (INIS)

    Lemire, A.E.

    1989-08-01

    Radionuclides released to the environment may cause external and internal radiation exposure to man via a number of potential pathways. The resulting radiation dose due to such releases from any operating facility must be kept below dose limits specified in the regulations issued by the Atomic Energy Control Board of Canada. At the Whiteshell Nuclear Research Establishment (WNRE), there is one primary source of liquid effluent to the Winnipeg River via the process water outfall. There are five sources of gaseous effluents: the WR-1 stack; the incinerator stack in the waste management area; the active laboratories building (including the hot cells); the Active-Liquid Waste Treatment Centre; and the compactor-baler in the Waste Management Area. This report presents the methodology and models used to calculate the maximum permissible release rates of radionuclides for each of these sources

  11. USERDA effluent data collection and reporting program

    International Nuclear Information System (INIS)

    Elle, D.R.; Schoen, A.A.

    1978-01-01

    Effluent and environmental monitoring has been conducted at United States Energy Research and Development Administration (formerly United States Atomic Energy Commission) facilities and sites virtually since the inception of atomic energy research and development. In 1971, computer systems were developed that permitted storage of information and data characterizing each effluent and onsite discharge point and relevant information on sources, effluent treatment and control systems, and discharge data, and serve as ERDA's computer-based management information systems for compiling waste discharge control and monitoring data on radioactivity released as airborne or liquid effluents or liquid discharges to onsite retention basins at ERDA facilities. The information systems and associated data outputs have proved to be an effective internal management tool for identifying effluent control problem areas and for surveying an agencywide Radioactive Effluent Reduction Program. The trend data facilitate the detection of gradual changes in the effectiveness of waste treatment systems, and errors or oversights in monitoring and data handling. Other computer outputs are useful for identifying effluent release points that have significantly higher or lower concentrations or quantities in the discharge stream than were measured the previous year. The year-to-year trend reports and the extensive computer edit and error checks have improved the reliability of the reported effluent data. Adoption of a uniform, centralized reporting system has improved the understanding and credibility of effluent data, and has allowed management to evaluate the effectiveness of effluent control practices at ERDA facilities. (author)

  12. Study of radiation processes for purifying liquid effluent and the design of pilot plants

    International Nuclear Information System (INIS)

    Kon'kov, N.G.; Buslaeva, S.P.; Osipov, V.B.; Panin, Yu.A.; Solodikhina, L.D.; Upadyshev, L.B.; Karpukhin, V.F.; Fajngol'd, Z.L.

    1975-01-01

    The possibilities of purifying liquid effluent containing dyestuffs and various organic and biological pollutants with an accelerated electron beam of energy up to 0.7 MeV are examined. A laboratory plant has been erected for the stationary, continuous irradiation - with bubbling of air - of artificial and natural industrial effluent containing organic pollutants in concentrations of up to 2g/litre and the 5 SKh dye in concentrations of up to 220 mg/litre. The results are discussed of the experimental irradiation of artificial mixtures consisting of distilled water, organic pollutants and dyestuffs, and also of natural industrial effluents from an enterprise where antibiotics are produced and from textile mills. The results of the studies indicate that the physicochemical characteristics of effluents are improved. On the basis of these studies pilot plants with electron accelerators are being designed for a daily throughput of 15 000 m 3 of effluent from the production of antibiotics. The electron accelerators are of the transformer type (EhLV-1) with an energy of up to 0.7 MeV and a power of up to 40 kW. In addition, units with a daily throughput of 200 m 3 are being designed for the breakdown of cyanides in effluent by 60 Co. Such a unit consists of three reactors with centro-axial irradiators and solid cast-iron biological shielding. The dose-rate can be measured over a wide range, thanks to the use of spherical source holders. The sources have a total activity of 62 kCi. Calculations of the cost of the radiation treatment of effluent demonstrate the economic feasibility of the method

  13. 200 Area Effluent Treatment Facility: Delisting petition

    International Nuclear Information System (INIS)

    1993-08-01

    Waste water has been generated for over 40 years as a result of operations conducted on the Hanford Site. This waste water previously was discharged to cribs, ponds, or ditches. An example of such waste water includes process condensate that might have been in contact with dangerous waste or mixed waste (containing both radioactive and dangerous components). This petition presents the treatment technologies that are designed into the 200 Area Effluent Treatment Facility to eliminate the dangerous characteristics of the waste and to delist the effluent in accordance with the requirements found in 40 Code of Federal Regulations 260.20 and 260.22. The purpose of this petition is to demonstrate that the 242-A Evaporator process condensate will be treated adequately so that the effluent from the 200 Area Effluent Treatment Facility will no longer require management as a regulated dangerous waste. This demonstration was performed by use of a surrogate (synthetic) waste, designed by the US Department of Energy, Richland Operations Office to include species that represent all organic and inorganic constituents (but not radionuclide species) expected to be found on the Hanford Site. Thus, the surrogate will encompass not only the expected 242-A Evaporator process condensate characteristics, but those of other potential 200 Area Effluent Treatment Facility waste streams and additional 40 CFR Appendix VIII constituents

  14. Effluent Treatment Facility tritium emissions monitoring

    International Nuclear Information System (INIS)

    Dunn, D.L.

    1991-01-01

    An Environmental Protection Agency (EPA) approved sampling and analysis protocol was developed and executed to verify atmospheric emissions compliance for the new Savannah River Site (SRS) F/H area Effluent Treatment Facility. Sampling equipment was fabricated, installed, and tested at stack monitoring points for filtrable particulate radionuclides, radioactive iodine, and tritium. The only detectable anthropogenic radionuclides released from Effluent Treatment Facility stacks during monitoring were iodine-129 and tritium oxide. This paper only examines the collection and analysis of tritium oxide

  15. The treatment of liquid effluents from the nuclear industry

    International Nuclear Information System (INIS)

    Carley-Macauly, K.W.

    1983-01-01

    This paper reviews the sources, and principles of management, of radioactive liquid wastes in the nuclear industry. The selection of processes for their treatment is based on consideration of the solution chemistry and of the total system for active waste disposal which must ensure that the activity or radiation dose arriving in the biosphere is kept within acceptable limits. Treatment processes aim primarily at concentration of the active species into a small volume, as by evaporation, selective ion exchange or precipitation. These well established methods have counterparts or developments among the more novel means of separation, such as membrane processes. (author)

  16. Toxicity assays applied for evaluation of ionizing radiation and zeolites adsorption as treatment technologies for coloured effluent

    International Nuclear Information System (INIS)

    Higa, Marcela Cantelli

    2008-01-01

    Textile industry is one raising commercial activity in Brazil. This activity has been generating important environmental interferences such as colour and bad biological effects into aquatic environment. Liquid textile effluents are toxic to lived organisms and may present low biological degradability. Although foreseen at federal regulation, the effluent quality is not controlled by toxicity assays in the country. These assays are carried out to determine the potential effects of chemical substances and effluents to cause negative effects to the exposed organisms. The present work aimed whole toxicity evaluation as well as the applicability of two different treatment techniques: ionizing radiation and zeolite adsorption. The efficacy of them were evaluated using eco toxicity bases and real effluents. Two different industries from Sao Paulo State contributed to this project supplying their real effluents. The samples were collected at a Textile Industry and at a Chemical Industry (dying producer) and after the measurement of whole toxicity the samples were submitted to treatments. Toxicity assays were carried out for Daphnia similis and for Vibrio fischeri. Sample irradiations were performed at an Electron Beam Accelerator at CTR/IPEN. Zeolites treatment is an P and D activity from CQMA/IPEN which contributed to this Project. Zeolites v/ere prepared from fly ash previously being used as an adsorber material. Both treatments (electron irradiation and zeolite adsorption) resulted on important toxicity and colour reduction. Concerning irradiation the effluents from chemical industry required higher radiation doses than that from textile activity. The radiation dose to be suggested is 40 kGy (toxicity reduction > 60%) for the chemical effluents and 0.5 kGy for the textile effluents (toxicity reduction > 90%). When zeolite adsorption was evaluated the Z1M6 resulted in 85%o v/hole toxicity reduction and ZC6 resulted in very low efficiency for the effluents of chemical

  17. Screening for crude oil degrading bacteria in liquid organic waste (effluent samples)

    International Nuclear Information System (INIS)

    Akpe, A.R.

    2014-01-01

    The screening for crude oil degrading bacteria in some liquid organic wastes (cassava mill effluents, rubber effluents and oil palm mill effluents) was carried out. Hydrocarbon utilising bacteria were isolated on mineral salt agar using vapour phase technique. The samples yielded 20 bacterial isolates from 13 different genera. Cassava mill effluent and rubber effluent had the highest number (7), while oil palm effluent had the least number (6) of bacterial isolates. The isolates that had the highest occurrence (occurring in all samples) were Pseudomonas aeruginosa and Escherichia coli. Of these 13 genera 9 were gram negative, while only 4 were gram positive. The total heterotrophic bacterial (THB) count and total hydrocarbon utilisers (THU) from all the effluent samples ranged from 3.0 * 10/sup 4/ to 6.0* 10/sup 7/ cfu/mL and 2.3 *10/sup 2/ to 4.2*10/sup 3/ cfu/mL, respectively. The counts of hydrocarbon utilisers were obviously lower than the heterotrophic counts, although the differences in counts were found to be statistically non-significant (P > 0.05). Rubber effluents and oil palm mill effluents had the highest number of hydrocarbon utilisers with three isolates each. The active hydrocarbon utilisers encountered in this study included Serratia marscescens, Bacillus cereus, P. aeruginosa, Enterobacter aerogenes and Bacillus subtilis. Presence of nutrients and crude oil degrading bacteria in these effluents suggests that these effluents can be used to enhance bioremediation through their use as biostimulation and bioaugmentation agents. (author)

  18. [Newly Designed Water Treatment Systems for Hospital Effluent].

    Science.gov (United States)

    Azuma, Takashi

    2018-01-01

     Pharmaceuticals are indispensable to contemporary life. Recently, the emerging problem of pharmaceutical-based pollution of river environments, including drinking water sources and lakes, has begun to receive significant attention worldwide. Because pharmaceuticals are designed to perform specific physiological functions in targeted regions of the human body, there is increasing concern regarding their toxic effects, even at low concentrations, on aquatic ecosystems and human health, via residues in drinking water. Pharmaceuticals are consistently employed in hospitals to treat disease; and Japan, one of the most advanced countries in medical treatment, ranks second worldwide in the quantity of pharmaceuticals employed. Therefore, the development of technologies that minimize or lessen the related environmental risks for clinical effluent is an important task as well as that for sewage treatment plants (STPs). However, there has been limited research on clinical effluent, and much remains to be elucidated. In light of this, we are investigating the occurrence of pharmaceuticals, and the development of water treatment systems for clinical effluent. This review discusses the current research on clinical effluent and the development of advanced water treatment systems targeted at hospital effluent, and explores strategies for future environmental risk assessment and risk management.

  19. Effluent from Wastewater Treatment Plants

    DEFF Research Database (Denmark)

    Kristensen, Jannie Munk; Nierychlo, Marta; Albertsen, Mads

    Incoming microorganisms to wastewater treatment plants (WWTPs) are usually considered to be removed in the treatment process. Analyses of the effluent generally show a very high degree of reduction of pathogens supporting this assumption. However, standard techniques for detecting bacteria......-independent 16SrRNA gene amplicon sequencing was applied for the identification and quantification of the microorganisms. In total 84 effluent samples from 14 full-scale Danish wastewater treatment plants were investigated over a period of 3 months. The microbial community composition was investigated by 16S r...... contain pathogenic species. One of these was Arcobacter (Campylobacteraceae) which was found in up to 16% relative abundance. This indicates that Arcobacter, and perhaps other pathogenic genera, are not being removed efficiently in full-scale plants and may pose a potential health safety problem. Further...

  20. Physiochemical Treatment of Textile Industry Effluents

    International Nuclear Information System (INIS)

    Latif, M. I.; Qazi, M. A.; Khan, H.; Ahmad, N.

    2015-01-01

    The study mainly focuses on the application of chemical Coagulants (Lime, Alum and Ferrous Sulfate) and Advanced Oxidation Processes (AOPs) (Ozone Treatment and Fenton Process, alone and in combination) to treat textile industry effluents, optimization of coagulation process for various Coagulants in terms of process conditions, including coagulant dose, pH and settling time. The results revealed that Alum was most effective. The efficiency of coagulation process was dose dependent and 400 mg/L dose of Alum alone showed maximum color removal of 47%, 57% and 54% of yellow, red and blue dyes, respectively in addition to the COD removal of 44%. The combined applications of Alum and Lime (300:75 mg/L) and Lime and Alum (300:75 mg/L) showed slightly better COD removal of 51%. However, color removal efficiency of all coagulants was at par. The Ozonation process appeared the most promising for the treatment of waste water and color/COD removal, the efficiency of which increased with increasing the treatment time at constant Ozone dose. For less polluted effluents, 97% color removal was obtained after 1 minute and after 15 minutes for highly polluted effluents; The COD removal efficiency of the process for less polluted effluents was around 89% after 5 minutes Ozonation and for highly polluted effluents 88% COD removal after 40 minutes. The performance of Fenton process was extremely low as compared to Ozonation process. Increase in pH, significantly decreased the color removal efficiency of the process. COD removal efficiency of Fenton process increased with an increase in settling time. (author)

  1. EU-wide monitoring survey on emerging polar organic contaminants in wastewater treatment plant effluents.

    Science.gov (United States)

    Loos, Robert; Carvalho, Raquel; António, Diana C; Comero, Sara; Locoro, Giovanni; Tavazzi, Simona; Paracchini, Bruno; Ghiani, Michela; Lettieri, Teresa; Blaha, Ludek; Jarosova, Barbora; Voorspoels, Stefan; Servaes, Kelly; Haglund, Peter; Fick, Jerker; Lindberg, Richard H; Schwesig, David; Gawlik, Bernd M

    2013-11-01

    In the year 2010, effluents from 90 European wastewater treatment plants (WWTPs) were analyzed for 156 polar organic chemical contaminants. The analyses were complemented by effect-based monitoring approaches aiming at estrogenicity and dioxin-like toxicity analyzed by in vitro reporter gene bioassays, and yeast and diatom culture acute toxicity optical bioassays. Analyses of organic substances were performed by solid-phase extraction (SPE) or liquid-liquid extraction (LLE) followed by liquid chromatography tandem mass spectrometry (LC-MS-MS) or gas chromatography high-resolution mass spectrometry (GC-HRMS). Target microcontaminants were pharmaceuticals and personal care products (PPCPs), veterinary (antibiotic) drugs, perfluoroalkyl substances (PFASs), organophosphate ester flame retardants, pesticides (and some metabolites), industrial chemicals such as benzotriazoles (corrosion inhibitors), iodinated x-ray contrast agents, and gadolinium magnetic resonance imaging agents; in addition biological endpoints were measured. The obtained results show the presence of 125 substances (80% of the target compounds) in European wastewater effluents, in concentrations ranging from low nanograms to milligrams per liter. These results allow for an estimation to be made of a European median level for the chemicals investigated in WWTP effluents. The most relevant compounds in the effluent waters with the highest median concentration levels were the artificial sweeteners acesulfame and sucralose, benzotriazoles (corrosion inhibitors), several organophosphate ester flame retardants and plasticizers (e.g. tris(2-chloroisopropyl)phosphate; TCPP), pharmaceutical compounds such as carbamazepine, tramadol, telmisartan, venlafaxine, irbesartan, fluconazole, oxazepam, fexofenadine, diclofenac, citalopram, codeine, bisoprolol, eprosartan, the antibiotics trimethoprim, ciprofloxacine, sulfamethoxazole, and clindamycine, the insect repellent N,N'-diethyltoluamide (DEET), the pesticides

  2. Development of improved liquid radioactive effluents treatment technology by precipitation and ion exchange and the related analytical control system

    International Nuclear Information System (INIS)

    Rahman, M.M.; Mollah, A.S.; Alam, M.K.; Begum, A.; Islam, S.; Koddus, A.

    1997-01-01

    Chemical precipitation method for treatment of LLW and ILW by co-precipitation of caesium with nickel ferrocyanide was employed. High decontamination factors were observed in the pH range of 9 to ∼ 11. The percentage removals of 137 Cs from 37 kBq, 370 kB and 3.4 MBq per litre of simulated effluents were ∼ 90%, 99.7% and 99.8% respectively. Liquid radioactive wastes generated from radioisotope production facilities of AERE, Savar were found to contain 134 Cs and 60 Co with the average activity levels of 13.23 kBq/L and 5.3 kBq/L, respectively. Test runs for removal of 134 Cs from the wastes varied from ∼ 90% to 99%. The radioactive concentrates (sludges) were conditioned by cementation and safely stored in interim storage room. (author). 4 refs, 1 fig., 9 tabs

  3. Elimination of slightly radioactive liquid effluent by dilution. Its consequences (1960)

    International Nuclear Information System (INIS)

    Bovard, P.; Candillon, C.

    1960-01-01

    Nuclear centres often have to solve problems raised by the elimination of large volumes of slightly radioactive liquid effluent. As things stand at present, the method usually adopted consists in expelling this effluent into the main water system in order to dilute it to a maximum, and thus to lower its radioactive isotope concentration to below the norms imposed by the Public Health Service. This technique requires systematic checking of the water system and its dependences, and demands a thorough knowledge of adsorption and fixation processes. (author) [fr

  4. Electrocoagulation for the treatment of textile industry effluent--a review.

    Science.gov (United States)

    Khandegar, V; Saroha, Anil K

    2013-10-15

    Various techniques such as physical, chemical, biological, advanced oxidation and electrochemical are used for the treatment of industrial effluent. The commonly used conventional biological treatment processes are time consuming, need large operational area and are not effective for effluent containing toxic elements. Advanced oxidation techniques result in high treatment cost and are generally used to obtain high purity grade water. The chemical coagulation technique is slow and generates large amount of sludge. Electrocoagulation has recently attracted attention as a potential technique for treating industrial effluent due to its versatility and environmental compatibility. This technique uses direct current source between metal electrodes immersed in the effluent, which causes the dissolution of electrode plates into the effluent. The metal ions, at an appropriate pH, can form wide range of coagulated species and metal hydroxides that destabilize and aggregate particles or precipitate and adsorb the dissolved contaminants. Therefore, the objective of the present manuscript is to review the potential of electrocoagulation for the treatment of industrial effluents, mainly removal of dyes from textile effluent. © 2013 Elsevier Ltd. All rights reserved.

  5. The main rules regarding the management of solid waste and liquid effluent contaminated during use at nuclear medicine departments; Les principales regles de gestion des dechets solides et des effluents liquides contamines dans les services de medecine nucleaire

    Energy Technology Data Exchange (ETDEWEB)

    Boudouin, E. [Autorite de Surete Nucleaire, Direction des rayonnements ionisants et de la sante, 75 - Paris (France)

    2011-02-15

    This article describes the key requirements applicable to the management of contaminated medical waste and effluent from hospitals and health care centres, and more especially from nuclear medicine departments that use radionuclides for the purposes of diagnosis (in vivo or in vitro) or in patient treatment. It also presents the key management regulations, making a distinction between contaminated solid waste and contaminated liquid waste from such nuclear medicine departments. (author)

  6. Control system of liquid effluents generated in treatment with I-131; Sistema de control de efluentes liquidos generados en el tratamiento con I-131

    Energy Technology Data Exchange (ETDEWEB)

    Garcia M, T.; Ruiz C, M. A.; Angeles C, A.; Ramirez S, R., E-mail: teodoro.garcia@inin.gob.mx [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2015-09-15

    In recent years, nuclear medicine has developed greatly in our country and around the world. Techniques for both medical diagnosis and therapy have increased the use of radiopharmaceuticals, notably the I-131. In Mexico there are around 150 nuclear medicine establishments authorized by the Comision Nacional de Seguridad Nuclear y Salvaguardias. Most of these establishments do not have an appropriate facility for the treatment of radioactive liquid effluents, to ensure compliance with the concentration limits established in the regulations. The Instituto Nacional de Investigaciones Nucleares (ININ) developed and implemented successfully, a control system of radioactive effluents (named SACEL) from a nuclear medicine facility. This system ensures an effective compliance with regulations and also better management and control of these radioactive effluents. Calculations and design of SACEL were made with respect to I-131, because is one of the most commonly used in radiotherapy and medical diagnostics, besides its half-life is greater in relation to other radionuclides. SACEL is comprised of four storage tanks and decay and a fifth tank for measuring the concentration of I-131 and later discharge to the drain; these tanks are connected to an automated system that controls the effluents passage. The calculation to determine the volume of the tanks was carried out according to the demand that has the hospital, to the maximum activity being poured in effluents and time required to decay. In this paper the design and installation of SACEL system, in addition to functioning as a facility that enables the Hospital meet the required standards is presented. Dose calculations performed with MCNPX and the methodology used in the calibration of the detection system is also presented. (Author)

  7. Methanization of industrial liquid effluents; Methanisation des effluents industriels liquides

    Energy Technology Data Exchange (ETDEWEB)

    Frederic, S.; Lugardon, A. [Societe Naskeo Environnement, 92 - Levallois-Perret (France)

    2007-09-15

    In a first part, this work deals with the theoretical aspects of the methanization of the industrial effluents; the associated reactional processes are detailed. The second part presents the technological criteria for choosing the methanization process in terms of the characteristics of the effluent to be treated. Some of the methanization processes are presented with their respective advantages and disadvantages. At last, is described the implementation of an industrial methanization unit. The size and the main choices are detailed: the anaerobic reactor, the control, the valorization aspects of the biogas produced. Some examples of industrial developments illustrate the different used options. (O.M.)

  8. Hydroponic system for the treatment of anaerobic liquid.

    Science.gov (United States)

    Krishnasamy, K; Nair, J; Bäuml, B

    2012-01-01

    The effluent from anaerobic digestion process has high concentrations of nutrients, particularly nitrogen, essential for plant growth but is not suitable for direct disposal or application due to high chemical oxygen demand (COD), low dissolved oxygen (DO), odour issues and is potentially phytotoxic. This research explored the optimum conditions of anaerobic effluent for application and dilutions of the effluent required to obtain better plant growth. A small-scale hydroponic system was constructed in a glasshouse to test different concentrations of anaerobic effluent against a commercial hydroponic medium as the control for the growth of silverbeet. It was found that the survival of silverbeet was negatively affected at 50% concentration due to low DO and NH(4) toxicity. The concentration of 20% anaerobic liquid was found to be the most efficient with highest foliage yield and plant growth. The hydroponic system with 20% concentrated effluent had better utilisation of nutrients for plant growth and a COD reduction of 95% was achieved during the 50-day growth period. This preliminary evaluation revealed that the growth and development of silverbeet was significantly lower in anaerobic effluent compared with a commercial hydroponic plant growth solution. The nutrient quality of anaerobic effluent could be highly variable with the process and the waste material used and dilution may depend on the nutrient content of the effluent. It is recommended that, a pre-treatment of the effluent to increase DO and reduce ammonium content is required before plant application, and simple dilution by itself is not suitable for optimum plant growth in a hydroponic system.

  9. Predicting chromium (VI) adsorption rate in the treatment of liquid ...

    African Journals Online (AJOL)

    The adsorption rate of chromium (VI) on commercial activated carbon during the treatment of the flocculation effluent of liquid-phase oil-based drill-cuttings has been investigated in terms of contact time and initial chromium (VI) ion concentration. Homogenizing 1 g of the activated carbon with 100 ml of the flocculation ...

  10. Development of improved liquid radioactive effluents treatment technology by precipitation and ion exchange and the related analytical control system

    Energy Technology Data Exchange (ETDEWEB)

    Rahman, M M; Mollah, A S; Alam, M K; Begum, A; Islam, S; Koddus, A [Institute of Nuclear Science and Technology, Savar, Dacca (Bangladesh)

    1997-02-01

    Chemical precipitation method for treatment of LLW and ILW by co-precipitation of caesium with nickel ferrocyanide was employed. High decontamination factors were observed in the pH range of 9 to {approx} 11. The percentage removals of {sup 137}Cs from 37 kBq, 370 kB and 3.4 MBq per litre of simulated effluents were {approx} 90%, 99.7% and 99.8% respectively. Liquid radioactive wastes generated from radioisotope production facilities of AERE, Savar were found to contain {sup 134}Cs and {sup 60}Co with the average activity levels of 13.23 kBq/L and 5.3 kBq/L, respectively. Test runs for removal of {sup 134}Cs from the wastes varied from {approx} 90% to 99%. The radioactive concentrates (sludges) were conditioned by cementation and safely stored in interim storage room. (author). 4 refs, 1 fig., 9 tabs.

  11. Environmental system applied to radioactive liquid effluent release

    International Nuclear Information System (INIS)

    Nisti, Marcelo Bessa

    2009-01-01

    The current environmental administration considers the productive activity as an environmental system, defined as a group of processes, interactions, parameters and factors involved in the production. This mastering dissertation evaluated the release of the liquid radioactive effluents at Instituto de Pesquisas Energeticas e Nucleares (IPEN), under a systemic environmental study. The study evaluated the source term at IPEN in the period from 2004 to 2008, making use of gamma-ray and alpha spectrometry, instrumental neutron activation analysis, liquid phase scintillation and atomic absorption spectrometry. The employed methodologies were verified using samples from the Intercomparison National Program - PNI/IRD and Reference Materials. The facilities that contributed the most in these releases were the Radiopharmaceutical Center (CR) and the Research Reactor Center (CRPq) with an average of 11,4% and 87,4%, respectively, relative to the present radioactive activity. The sewer system releases were within the radioactive protection regulations, showing the effectiveness of IPEN's Radioactive Effluents Monitoring Program. The concentration of the stable elements Ag, Cd, Cr, Fe, Mn, Ni, Pb and Zn was determined in the liquid effluent in ali the samples from the storage tanks TR1 and CR in the period from 2004 to 2008 and in some of the samples of other IPEN's facilities in the period from 2004 to 2007. Among the analyzed effluents, two samples were higher than the stable elements discharge standards established in the state of Sao Paulo, one sample was higher than the required value of the element cadmium and the other higher than required value of the element zinco The storage tank TR1 discharge flow was estimated in 10,9 ± 0,9 m3 h -1 . The dilution factor at discharge point E1 was estimated using a radiotracers the isotopes 3 H, 137 CS, 60 Co, 54 Mn and 65 Zn, which are commonly released into IPEN's sewer system. The executed radiotracer study was carried out

  12. Performance evaluation of effluent treatment plant for automobile industry

    Energy Technology Data Exchange (ETDEWEB)

    Ansari, Farid [Department of Applied Science and Humanities, PDM College of Engineering, Bahadurgarh (Haryana) (India); Pandey, Yashwant K. [School of Energy and Environmental Studies, Devi Ahilya Vishwavidyalaya, Indore (India); Kumar, P.; Pandey, Priyanka [Department of Environmental Science, Post Graduate College Ghazipur (IN

    2013-07-01

    The automobile industry’s wastewater not only contains high levels of suspended and total solids such as oil, grease, dyestuff, chromium, phosphate in washing products, and coloring, at various stages of manufacturing but also, a significant amount of dissolved organics, resulting in high BOD or COD loads. The study reveals the performance, evaluation and operational aspects of effluent treatment plant and its treatability, rather than the contamination status of the real property. The Results revealed that the treated effluent shows most of the parameters are within permissible limits of Central Pollution Control Board (CPCB), India and based on the site visits, discussion with operation peoples, evaluation of process design, treatment system, existing effluent discharge, results of sample analyzed and found that effluent treatment plant of automobile industry are under performance satisfactory.

  13. Liquid effluent retention facility final-status groundwater monitoring plan

    International Nuclear Information System (INIS)

    Sweeney, M.D.; Chou, C.J.; Bjornstad, B.N.

    1997-09-01

    The following sections describe the groundwater-monitoring program for the Liquid Effluent Retention Facility (LERF). The LERF is regulated under the Resource Conservation and Recovery Act of 1976 (RCRA). The LERF is included in the open-quotes Dangerous Waste Portion of the Resource Conservation and Recovery Act Permit for the Treatment, Storage, and Disposal of Dangerous Waste, Permit WA890008967close quotes, (referred to herein as the Permit) (Ecology 1994) and is subject to final-status requirements for groundwater monitoring (WAC 173-303-645). This document describes a RCRA/WAC groundwater detection-monitoring program for groundwater in the uppermost aquifer system at the LERF. This plan describes the LERF monitoring network, constituent list, sampling schedule, statistical methods, and sampling and analysis protocols that will be employed for the LERF. This plan will be used to meet the groundwater monitoring requirements from the time the LERF becomes part of the Permit and through the post-closure care period, until certification of final closure

  14. Comprehensive Two-dimensional Liquid Chromatography coupled to High Resolution Time of Flight Mass Spectrometry for Chemical Characterization of Sewage Treatment Plant Effluents

    NARCIS (Netherlands)

    Ouyang, X.; Leonards, P.E.G.; Legler, J.; van der Oost, R.; de Boer, J.; Lamoree, M.H.

    2015-01-01

    For the first time a comprehensive two-dimensional liquid chromatography (LC. ×. LC) system coupled with a high resolution time-of-flight mass spectrometer (HR-ToF MS) was developed and applied for analysis of emerging toxicants in wastewater effluent. The system was optimized and validated using

  15. Alternatives for biodigester effluent treatment: economic impact; Impacto economico de um sistema de tratamento dos efluentes de biodigestores

    Energy Technology Data Exchange (ETDEWEB)

    Miele, Marcelo; Kunz, Airton; Correa, Juliano Corulli; Steinmetz, Ricardo [EMBRAPA Suinos e Aves, Concordia, SC (Brazil)], email: marcelo@cnpsa.embrapa.br; Bortoli, Marcelo [Universidade Federal de Santa Catarina, (UFSC), Florianopolis, SC (Brazil)

    2011-07-01

    The aim of this study was to present a prospective economic impact assessment of a biodigester liquid effluent treatment system. This system developed by Embrapa Swine and Poultry is composed by a N removal module and a P one, which can be attached to a biodigester, technology widely diffused in Brazil. Biodigesters do not remove nutrients (NPK) with high pollution potential of water resources and demanding high effluent transport costs. The analysis was based on Net Present Value (NPV) technique, using prototype performance information, market prices and wastewater analysis. The N module reduces more than ten times the surface needed to spread effluents. The P module attains the standard for discharge in water resources and makes this element available as fertilizer. The system has a significant impact on swine production costs, what can be reduced in farms which produces its own energy from manure. High effluent distribution costs also turn treatment more attractive. The study concludes that this is a promising technology which has to be validated. Financial support is needed to implement a real scale prototype to validate it. (author)

  16. 40 CFR 417.162 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SOAP AND DETERGENT MANUFACTURING POINT SOURCE CATEGORY Manufacture of Liquid Detergents Subcategory § 417.162 Effluent limitations guidelines... available (BPT): (a) For normal liquid detergent operations the following values pertain: Effluent...

  17. Automated system of control of radioactive liquid effluents of patients submitted to therapy in hospitals of nuclear medicine (SACEL)

    International Nuclear Information System (INIS)

    Ruiz C, M.A.; Rivero G, T.; Celis del Angel, L.; Sainz M, E.; Molina, G.

    2006-01-01

    Different hospitals of nuclear medicine require of the technical attendance for the design, construction and instrumentation of an effluents retention system coming from the room dedicated to the medical application of iodine 131, with the one object of giving execution to the normative requirements of radiological protection, settled down in the General Regulation of Radiological Safety (RGSR) emitted by the CNSNS in November, 1988 and in the corresponding official standards. An automatic system of flow measurement, the activity concentration of the effluents to the drainage, the discharges control and the automated report it will allow the execution of the national regulations, also the elimination of unhealthy activities as the taking of samples, analysis of those same and the corresponding paperwork, its will allow that the SACEL is capable of to carry out registrations that are to consult in an automated way. The changes in the demands of the National Commission of Nuclear Safety and Safeguards in relation to the liberation of radioactive material in hospitals by medical treatments, it has created the necessity to develop a system that quantifies and dose the liquid effluents of people under thyroid treatment with iodine-131 to the drainage. The Automated System of Control of radioactive liquids effluents generated in Hospitals of Nuclear Medicine (SACEL) developed in the National Institute of Nuclear Research, it fulfills this regulation, besides improving the work conditions for the medical and technical personnel of the hospital in that are installed, since this system has the advantage of to be totally automated and to require of a minimum of attendance. The SACEL is an electro-hydraulic system of effluents control, based in the alternate operation of two decay deposits of the activity of the material contaminated with iodine-131. The system allows to take a registration of those volumes and liberated dose, besides being able to be monitoring in remote

  18. An automation model of Effluent Treatment Plant

    Directory of Open Access Journals (Sweden)

    Luiz Alberto Oliveira Lima Roque

    2012-07-01

    Full Text Available Population growth and intensification of industrial activities have increased the deterioration of natural resources. Industrial, hospital and residential wastes are dumped directly into landfills without processing, polluting soils. This action will have consequences later, because the liquid substance resulting from the putrefaction of organic material plows into the soil to reach water bodies. Cities arise without planning, industrial and household wastes are discharged into rivers, lakes and oceans without proper treatment, affecting water resources. It is well known that in the next century there will be fierce competition for fresh water on the planet, probably due to the scarcity of it. Demographic expansion has occurred without proper health planning, degrading oceans, lakes and rivers. Thus, a large percentage of world population suffers from diseases related to water pollution. Accordingly, it can be concluded that sewage treatment is essential to human survival, to preserve rivers, lakes and oceans. An Effluent Treatment Plant (ETP treats wastewater to reduce its pollution to acceptable levels before sending them to the oceans or rivers. To automate the operation of an ETP, motors, sensors and logic blocks, timers and counters are needed. These functions are achieved with programmable logic controllers (PLC and Supervisory Systems. The Ladder language is used to program controllers and is a pillar of the Automation and Control Engineering. The supervisory systems allow process information to be monitored, while the PLC are responsible for control and data acquisition. In the age we live in, process automation is used in an increasing scale in order to provide higher quality, raise productivity and improve the proposed activities. Therefore, an automatic ETP will improve performance and efficiency to handle large volumes of sewage. Considering the growing importance of environmental awareness with special emphasis

  19. Demasculinization of male fish by wastewater treatment plant effluent

    Science.gov (United States)

    Vajda, A.M.; Barber, L.B.; Gray, J.L.; Lopez, E.M.; Bolden, A.M.; Schoenfuss, H.L.; Norris, D.O.

    2011-01-01

    Adult male fathead minnows (Pimephales promelas) were exposed to effluent from the City of Boulder, Colorado wastewater treatment plant (WWTP) under controlled conditions in the field to determine if the effluent induced reproductive disruption in fish. Gonadal intersex and other evidence of reproductive disruption were previously identified in white suckers (Catostomus commersoni) in Boulder Creek downstream from this WWTP effluent outfall. Fish were exposed within a mobile flow-through exposure laboratory in July 2005 and August 2006 to WWTP effluent (EFF), Boulder Creek water (REF), or mixtures of EFF and REF for up to 28 days. Primary (sperm abundance) and secondary (nuptial tubercles and dorsal fat pads) sex characteristics were demasculinized within 14 days of exposure to 50% and 100% EFF. Vitellogenin was maximally elevated in both 50% and 100% EFF treatments within 7 days and significantly elevated by 25% EFF within 14 days. The steroidal estrogens 17??-estradiol, estrone, estriol, and 17??-ethynylestradiol, as well as estrogenic alkylphenols and bisphenol A were identified within the EFF treatments and not in the REF treatment. These results support the hypothesis that the reproductive disruption observed in this watershed is due to endocrine-active chemicals in the WWTP effluent. ?? 2011 Elsevier B.V.

  20. In-Plant Corrosion Study of Steels in Distillery Effluent Treatment Plant

    Science.gov (United States)

    Ram, Chhotu; Sharma, Chhaya; Singh, A. K.

    2015-05-01

    The present study deals with corrosion and performance of steels observed in an effluent treatment plant (ETP) of a distillery. For this purpose, the metal coupons were exposed in primary (untreated effluent) and secondary tank (anaerobic treatment effluent) of the ETP. The extent of attack has been correlated with the composition of the effluent with the help of laboratory immersion and electrochemical tests. Untreated distillery effluent found to be more corrosive than the anaerobic-treated effluents and is assigned due to chloride, phosphate, calcium, nitrate, and nitrite ions, which enhances corrosivity at acidic pH. Mild steel showed highest uniform and localized corrosion followed by stainless steels 304L and 316L and lowest in case of duplex 2205.

  1. Effluent treatment efficiency and compliance monitoring in Nigerian ...

    African Journals Online (AJOL)

    The effectiveness of effluent treatment at the Eleme Petrochemical Industry, Port Harcourt, Nigeria was monitored weekly for six weeks to assess their level of compliance with the Directorate of Petroleum Resources (DPR) guidelines and standards for environmental safety. Effluent samples were taken from the untreated ...

  2. On-line immunoaffinity column-liquid chromatography-tandem mass spectrometry method for trace analysis of diuron in wastewater treatment plant effluent sample.

    Science.gov (United States)

    Zhang, Xiuli; Martens, Dieter; Krämer, Petra M; Kettrup, Antonius A; Liang, Xinmiao

    2006-11-10

    An on-line immunoaffinity column with liquid chromatography/tandem mass spectrometry (IAC-LC-MS/MS) method for the determination of diuron in water matrices was described. This method used a sol-gel immunoaffinity column (20 mm x 4 mm I.D.) for on-line sample cleanup and enrichment, a monolithic analytical column (100 mm x 4.6 mm I.D.) for separation, and a triple quadrupole mass spectrometer for quantitation. The major challenges for the on-line set-up were discussed. The optimized on-line protocol was emphasized by the fact that low limit of quantitation (LOQ) of 1.0 ng/L was achieved with only 2.5-mL sample. In addition, a satisfactory accuracy ( approximately 90% of recovery) and precision (effect, the on-line IAC-LC-MS/MS analysis method can reliably determine diuron in wastewater treatment plant effluent sample.

  3. An assessment of the quality of liquid effluents from opaque beer ...

    African Journals Online (AJOL)

    driniev

    2005-01-01

    Jan 1, 2005 ... The effluent treatment plants in both plants were not only inadequate but also ... Keywords: industrial effluents, opaque beer-brewery, pollution load, quality, quantity ... to hydraulic overloading and corrosion of the sewer pipe system ... The two breweries studied in this paper produce African traditional.

  4. Continuously tritium monitoring of the pipe of liquid effluents at the Cea Cadarache; Controle en continu du tritium de la conduite des effluents liquides du CEA Cadarache

    Energy Technology Data Exchange (ETDEWEB)

    Pira, Y

    2004-07-01

    This report is oriented toward the radiation protection of environment that is an essential component of radiation protection. It is necessary to detect any solid, liquid or gaseous abnormal release and to find its origin. The present study bears on a detection instrument in continuously to find tritium in liquid effluents of the Cea Cadarache. After having study the functioning principle of this device, an evaluation of its performances has been realised ( back noise, yield, detection limit) and to a checking in real conditions of utilization. (N.C.)

  5. The main rules regarding the management of solid waste and liquid effluent contaminated during use at nuclear medicine departments

    International Nuclear Information System (INIS)

    Boudouin, E.

    2011-01-01

    This article describes the key requirements applicable to the management of contaminated medical waste and effluent from hospitals and health care centres, and more especially from nuclear medicine departments that use radionuclides for the purposes of diagnosis (in vivo or in vitro) or in patient treatment. It also presents the key management regulations, making a distinction between contaminated solid waste and contaminated liquid waste from such nuclear medicine departments. (author)

  6. Petroleum Refinery Effluents Treatment by Advanced Oxidation Process with Methanol

    Energy Technology Data Exchange (ETDEWEB)

    Shoucheng, Wen [Yangtze Univ., HuBei Jingzhou (China)

    2014-02-15

    Petroleum refinery effluents are waste originating from industries primarily engaged in refining crude oil. It is a very complex compound of various oily wastes, water, heavy metals and so on. Conventional processes are unable to effectively remove the chemical oxygen demand (COD) of petroleum refinery effluents. Supercritical water oxidation (SCWO) was proposed to treat petroleum refinery effluents. In this paper, methanol was used to investigate co-oxidative effect of methanol on petroleum refinery effluents treatment. The results indicated that supercritical water oxidation is an effective process for petroleum refinery effluents treatment. Adding methanol caused an increase in COD removal. When reaction temperature is 440 .deg. C, residence time is 20 min, OE is 0.5 and initial COD is 40000 mg/L, and COD removal increases 8.5%.

  7. Petroleum Refinery Effluents Treatment by Advanced Oxidation Process with Methanol

    International Nuclear Information System (INIS)

    Shoucheng, Wen

    2014-01-01

    Petroleum refinery effluents are waste originating from industries primarily engaged in refining crude oil. It is a very complex compound of various oily wastes, water, heavy metals and so on. Conventional processes are unable to effectively remove the chemical oxygen demand (COD) of petroleum refinery effluents. Supercritical water oxidation (SCWO) was proposed to treat petroleum refinery effluents. In this paper, methanol was used to investigate co-oxidative effect of methanol on petroleum refinery effluents treatment. The results indicated that supercritical water oxidation is an effective process for petroleum refinery effluents treatment. Adding methanol caused an increase in COD removal. When reaction temperature is 440 .deg. C, residence time is 20 min, OE is 0.5 and initial COD is 40000 mg/L, and COD removal increases 8.5%

  8. Treatment of effluents in uranium industry

    International Nuclear Information System (INIS)

    Ghosh, S.K.

    2009-01-01

    Uranium processing technology in India has matured in the last 50 years and is able to meet the country's requirement. Right from mining of the ore to milling and refining, effluents are generated and are being processed for their safe disposal. While the available technology is able to meet the regulatory limits of the effluents, the same may not be enough to meet the increased demand of uranium in the future. The increased population, urbanization and climate change are not only going to decrease the supply of process water but will also place increased restrictions on disposal to environment. This demands technologies that will generate less effluent for disposal and enable reuse and recycle concept to the extent possible. Presently used conventional physical-chemical methods, to contain the contaminants would, therefore, require further refinements. Contaminants like sulfates, chlorides etc in the effluent of uranium mill based on acid leach process are the concerns for the future plants. Hence, there is an urgent need for development of suitable methods for maximum recycle of the process effluents, which will also enable in minimizing the consumption of process water. A suitable membrane based process can be an option leaving a concentrated brine for reuse or for further treatment and disposal

  9. Performance of drippers in two filtering systems using sewage treatment effluent

    Directory of Open Access Journals (Sweden)

    Alexandre B. Dalri

    Full Text Available ABSTRACT The objective of this study was to evaluate the performance of three models of drippers using treated sewage effluent, pure and diluted, and two types of filters, screen and disc. The treated sewage effluent used in the experiment was collected from the city’s treatment plant. The experiment included 12 lateral lines with three types of emitters to apply pure (100% and diluted (50% effluent filtered by screen and disc filters. The combination of those factors set the treatments: T1 (50% effluent diluted in fresh water filtered by a screen filter; T2 (50% effluent diluted in fresh water filtered by a disc filter; T3 (pure effluent filtered by a screen filter; T4 (pure effluent filtered by a disc filter. The results showed that the flat type emitter is less sensitive to clogging, the disc filter is the most suitable to prevent clogging and the use of pure or diluted sewage effluent increases the drippers’ flow rate coefficient of variation.

  10. Design parameters for waste effluent treatment unit from beverages production

    Directory of Open Access Journals (Sweden)

    Mona A. Abdel-Fatah

    2017-09-01

    Full Text Available Based on a successful experimental result from laboratory and bench scale for treatment of wastewater from beverages industry, an industrial and efficient treatment unit is designed and constructed. The broad goal of this study was to design and construct effluent, cost effective and high quality treatment unit. The used technology is the activated sludge process of extended aeration type followed by rapid sand filters and chlorination as tertiary treatment. Experimental results have been considered as the basis for full scale design of the industrial capacity of 1600 m3/day treatment plant. Final effluent characteristics after treatment comply with Egyptian legalizations after reducing COD and BOD5 by about 97% and 95% respectively. So it is recommended to reuse treated effluent in textile industry in dyeing process.

  11. Treatment of industrial wastewater effluents using hydrodynamic cavitation and the advanced Fenton process.

    Science.gov (United States)

    Chakinala, Anand G; Gogate, Parag R; Burgess, Arthur E; Bremner, David H

    2008-01-01

    For the first time, hydrodynamic cavitation induced by a liquid whistle reactor (LWR) has been used in conjunction with the advanced Fenton process (AFP) for the treatment of real industrial wastewater. Semi-batch experiments in the LWR were designed to investigate the performance of the process for two different industrial wastewater samples. The effect of various operating parameters such as pressure, H2O2 concentration and the initial concentration of industrial wastewater samples on the extent of mineralization as measured by total organic carbon (TOC) content have been studied with the aim of maximizing the extent of degradation. It has been observed that higher pressures, sequential addition of hydrogen peroxide at higher loadings and lower concentration of the effluent are more favourable for a rapid TOC mineralization. In general, the novel combination of hydrodynamic cavitation with AFP results in about 60-80% removal of TOC under optimized conditions depending on the type of industrial effluent samples. The combination described herein is most useful for treatment of bio-refractory materials where the diminution in toxicity can be achieved up to a certain level and then conventional biological oxidation can be employed for final treatment. The present work is the first to report the use of a hydrodynamic cavitation technique for real industrial wastewater treatment.

  12. Radioactive Liquid Waste Treatment Facility Discharges in 2011

    Energy Technology Data Exchange (ETDEWEB)

    Del Signore, John C. [Los Alamos National Laboratory

    2012-05-16

    This report documents radioactive discharges from the TA50 Radioactive Liquid Waste Treatment Facilities (RLWTF) during calendar 2011. During 2011, three pathways were available for the discharge of treated water to the environment: discharge as water through NPDES Outfall 051 into Mortandad Canyon, evaporation via the TA50 cooling towers, and evaporation using the newly-installed natural-gas effluent evaporator at TA50. Only one of these pathways was used; all treated water (3,352,890 liters) was fed to the effluent evaporator. The quality of treated water was established by collecting a weekly grab sample of water being fed to the effluent evaporator. Forty weekly samples were collected; each was analyzed for gross alpha, gross beta, and tritium. Weekly samples were also composited at the end of each month. These flow-weighted composite samples were then analyzed for 37 radioisotopes: nine alpha-emitting isotopes, 27 beta emitters, and tritium. These monthly analyses were used to estimate the radioactive content of treated water fed to the effluent evaporator. Table 1 summarizes this information. The concentrations and quantities of radioactivity in Table 1 are for treated water fed to the evaporator. Amounts of radioactivity discharged to the environment through the evaporator stack were likely smaller since only entrained materials would exit via the evaporator stack.

  13. Membrane Treatment of Liquid Salt Bearing Radioactive Wastes

    International Nuclear Information System (INIS)

    Dmitriev, S. A.; Adamovich, D. V.; Demkin, V. I.; Timofeev, E. M.

    2003-01-01

    The main fields of introduction and application of membrane methods for preliminary treatment and processing salt liquid radioactive waste (SLRW) can be nuclear power stations (NPP) and enterprises on atomic submarines (AS) utilization. Unlike the earlier developed technology for the liquid salt bearing radioactive waste decontamination and concentrating this report presents the new enhanced membrane technology for the liquid salt bearing radioactive waste processing based on the state-of-the-art membrane unit design, namely, the filtering units equipped with the metal-ceramic membranes of ''TruMem'' brand, as well as the electrodialysis and electroosmosis concentrators. Application of the above mentioned units in conjunction with the pulse pole changer will allow the marked increase of the radioactive waste concentrating factor and the significant reduction of the waste volume intended for conversion into monolith and disposal. Besides, the application of the electrodialysis units loaded with an ion exchange material at the end polishing stage of the radioactive waste decontamination process will allow the reagent-free radioactive waste treatment that meets the standards set for the release of the decontaminated liquid radioactive waste effluents into the natural reservoirs of fish-farming value

  14. Determination and removal of antibiotics in secondary effluent using a horizontal subsurface flow constructed wetland.

    Science.gov (United States)

    Zhang, Chunhui; Ning, Ke; Zhang, Wenwen; Guo, Yuanjie; Chen, Jun; Liang, Chen

    2013-04-01

    Increased attention is currently being directed towards the potential negative effects of antibiotics and other PPCPs discharged into the aquatic environment via municipal WWTP secondary effluents. A number of analytical methods, such as high performance liquid chromatography technologies, including a high performance liquid chromatography-fluorescence method (HPLC-FLD), high performance liquid chromatography-UV detection method (HPLC-UV) and high performance liquid chromatography-mass spectrometry method (HPLC-MS), have been suggested as determination technologies for antibiotic residues in water. In this study, we implement a HPLC-MS/MS combined method to detect and analyze antibiotics in WWTP secondary effluent and apply a horizontal subsurface flow constructed wetland (CW) as an advanced wastewater treatment for removing antibiotics in the WWTP secondary effluent. The results show that there were 2 macrolides, 2 quinolones and 5 sulfas in WWTP secondary effluent among all the 22 antibiotics considered. After the CW advanced treatment, the concentration removal efficiencies and removal loads of 9 antibiotics were 53-100% and 0.004-0.7307 μg m(-2) per day, respectively.

  15. Innovative processes for the treatment of radioactive liquid wastes

    International Nuclear Information System (INIS)

    Pacary, V.; Barre, Y.; Plasari, E.

    2008-01-01

    Full text of publication follows: Because of the high salinity (0.5 to 2 M) of liquid wastes and the variability of their composition, the method which is the most appropriate and commonly used to remove the contaminants consists in the in situ formation of adsorbent particles in the waste stream. This technique is often called coprecipitation. To increase the efficiency of this treatment, a study is performed to point out the impact of the choice of the process and the influence of operating parameters (mean residence time, stirring speed, etc.) on the formation of crystals and ultimately on their ability to capture radionuclide. Barium sulphate was chosen as a reference because it is a well known precipitate and a material used in the decontamination facilities to remove radiostrontium. Two issues are encountered with the classic treatments which are consequences of the variability of effluents composition. On the one hand when high activity effluents have to be treated, the efficiency of the classic processes can not be sufficient and the liquid must be once again decontaminated. Thus the volume of disposal waste produced by the treatment is doubled. On the other hand when low activity effluents have to be treated, the classic processes produce a low activity waste. Consequently the volume of storage occupied by this waste is disproportionate with regard to its low activity. To return the more flexible process, various configurations were tested. They can be classified in two categories: improvements of the classic treatments and new types of reactors. Because of the good results which are obtained, these processes are patent pending. To support the experimental investigations, a modelling study at the reactor scale is initiated to distinguish the influence of each process parameter. These models assume that the surface of adsorbent particles is continuously renewed by crystal growth. The aim of this work is to determine the decisive parameters which allow the

  16. Towards zero discharge by integrated effluent treatment approach

    International Nuclear Information System (INIS)

    Rath, Ashish Kumar; Pattnaik, Sambhu Prasad; Pati, Ganeswar; Saha, Sushant; Viswanath, Kowtha

    2014-01-01

    Heavy Water Plant, Talcher houses two Organo-phosphorus Solvent Production Plants namely, 60 MTPY TBP Plant engaged in the production of Tri-n-Butyl Phosphate and Versatile Solvent Production Plant (VSPP) capable of producing various Organo Phosphorus Solvents namely, 100 MTPY D2EHPA (Di-2-Ethyl Hexyl Phosphoric Acid), or 40 MTPY TAPO (Tri-Alkyl Phosphine Oxide) or TOPO (Tri-n-Octyl Phosphine Oxide) or DNPPA (Di-Nonyl Phenyl Phosphoric Acid). These solvents have important application for separation duties in front and back end of nuclear fuel cycle and also in conventional hydrometallurgy for separation metals like Ni, Cu, Zn, Co etc., both of these plants are first of their kind in India designed by the Heavy Water Board, Mumbai with R and D inputs from BARC. The two plants employ esterification (1) process between PCl 3 / and a suitable oxo-alcohol followed by hydrolysis, neutralization and product purification. The second and third steps find large usage of Water, which eventually surface as liquid effluent. All the gaseous emissions from plants, mostly HCl gas are traded off for Saline Water as liquid effluent by scrubbing the same with Sodium Hydroxide Solution

  17. Characterization of an acidification and equalization tank (AET operating as a primary treatment of swine liquid effluent

    Directory of Open Access Journals (Sweden)

    Fabrício Motteran

    2013-06-01

    Full Text Available This work evaluated the potential of the acidification equalization tank (AET used as a primary treatment unit, treating the hog farming wastewater. The treatment system consisted of a degritter with a triangular-notch weir, for measuring the flow, a static sieve, and an acidification and equalization tank (AET, an anaerobic baffled reactor (ABR, an upflow anaerobic sludge blanket (UASB reactor, a settling tank, a greenhouse for fertirrigation and two infiltration ponds. The AET had a net capacity of 8,000 liters, internally covered with asphalt blanket, worked based on surface loading rates application. The unit operated continuously, with its flow varying from 0.1 to 10 L s-1. To determine the efficiency, the following parameters were measured: pH; COD; BOD; volatile and fixed solids; settleable solids; total, intermediate and partial alkalinity and total acidity. The COD removal varied from 5 to 20%. The average pH was 7.3 and the total, intermediate and partial alkalinity in the effluent, were 1919, 846, 1197 mg L-1, respectively. The total acidity in the effluent was 34 mg L-1. The influent and effluent total BOD and oil & grease concentrations were 3436 and 3443 mg L-1, and 415 and 668 mg L-1, respectively. It was found that the AET worked properly concerning the acidification, equalization and sedimentation processes, confirming low cost of implementation and easy operation, when compared to other traditional decanters.

  18. Metal concentration of liquid effluents and surroundings of a pharmaceutical industry

    Directory of Open Access Journals (Sweden)

    E.I. Adeyeye

    2007-04-01

    Full Text Available Major and trace metals (Mg, Na, K, Ca, Fe, Zn, Cu, Sn, Al, Pb, As, Cr, Cd, Mn and Ti in liquid effluents, soil sediments and plant parts (roots and leaves from Tisco Nigeria Limited, Akure, were determined in both open effluent channel and closed direct tank. The plant in the open effluent channel was Pennisetum purpureum while the one around the direct tank was Chloris pilosa. The correlation coefficient (Cc of the metals in the open channel gave the values: soil sediments/water (0.61, roots/leaves (0.709; and (0.34, (0.91, respectively, in direct tank. F-test values showed that 67 % of the metals were significantly different (p < 0.05 among the samples. The soil sediments would serve as reservoir for all the metals determined. This was also the case for both plant roots with species variation. The plant leaves showed evidence of bioaccumulation of some metals. The high levels of Pb, As and Cd in the samples call for concern as environmental contaminants.

  19. The effect of advanced treatment of sewage effluents on metal speciation and (bio)availability.

    Science.gov (United States)

    Peters, A; Merrington, G; Leverett, D; Ellor, B; Lofts, S; Gravell, A

    2014-02-01

    The bioavailability of metals can be strongly influenced by dissolved organic carbon (DOC). Wastewater treatment effluents add considerable quantities of DOC and metals to receiving waters, and as effluent controls become more stringent advanced effluent treatments may be needed. We assessed the effects of two types of advanced treatment processes on metal availability in wastewater effluents. Trace metal availability was assessed using diffuse gradients in thin films and predicted through speciation modelling. The results show little difference in metal availability post-advanced treatment. EDTA-like compounds are important metal complexants in the effluents.

  20. Occurrences and fate of selected human antibiotics in influents and effluents of sewage treatment plant and effluent-receiving river Yamuna in Delhi (India).

    Science.gov (United States)

    Mutiyar, Pravin K; Mittal, Atul K

    2014-01-01

    Antibiotics consumption has increased worldwide, and their residues are frequently reported in aquatic environments. It is believed that antibiotics reach aquatic water bodies through sewage. Medicine consumed for healthcare practices are often released into sewage, and after sewage treatment plant, it reaches the receiving water bodies of lakes or rivers. In the present study, we determined the fate of some commonly used antibiotics in a sewage treatment plant (STP) located in Delhi and the environmental concentration of these antibiotics in the Yamuna River, which receives the sewage and industrial effluent of Delhi. There are many reports on antibiotics occurrences in STP and river water worldwide, but monitoring data from the Indian subcontinent is sparse. Samples were taken from a STP and from six sampling sites on the Yamuna River. Several antibiotics were tested for using offline solid-phase extraction followed by high-performance liquid chromatography equipped with photodiode array analysis. Recoveries varied from 25.5-108.8 %. Ampicillin had the maximum concentration in wastewater influents (104.2 ± 98.11 μg l(-1)) and effluents (12.68 ± 8.38 μg l(-1)). The fluoroquinolones and cephalosporins had the lower concentrations. Treatment efficiencies varied between 55 and 99 %. Significant amounts of antibiotics were discharged in effluents and were detected in the receiving water body. The concentration of antibiotics in the Yamuna River varied from not detected to 13.75 μg l(-1) (ampicillin) for the compounds investigated.

  1. Ion exchange for treatment of industrial effluents

    International Nuclear Information System (INIS)

    Moreno Daudinot, Aurora Maria; Ge Leyva, Midalis

    2016-01-01

    The acid leaching and ammoniacal carbonate technologies of laterite respectively, are responsible for the low quality of life of the local population, the big deforested areas due to the mining tilling, the elevated contents of solids in the air and waters, as well as the chemical contamination by metals presence, the acidity or basicity of the effluents of both industries, that arrive through the river and the bay to aquifer's mantle. The ion exchange resins allow ions separation contained in low concentrations in the solutions, where the separation of these elements for solvents, extraction or another chemical methods would be costly. Technological variants are proposed in order to reduce the impact produced on the flora and the fauna, by the liquid effluents of nickel industry, by means of ion exchange resins introduction as well as the recuperation of metals and their re incorporation to the productive process. (Author)

  2. Simultaneous determination of several veterinary pharmaceuticals in effluents from urban, livestock and slaughterhouse wastewater treatment plants using a simple chromatographic method.

    Science.gov (United States)

    Cavenati, Simone; Carvalho, Pedro N; Almeida, C Marisa R; Basto, M Clara P; Vasconcelos, M Teresa S D

    2012-01-01

    Minocycline, oxytetracycline, tetracycline, enrofloxacin and ceftiofur, commonly used veterinary pharmaceuticals, were searched in four urban, two livestock and two slaughterhouse effluents from wastewater treatment plants (WWTPs) in the north of Portugal. A simple method that includes solid-phase extraction followed with analysis by high-performance liquid chromatography with diode array detector was established and applied to the simultaneous determination of the five pharmaceuticals in WWTP effluents. This method, which is expeditious, inexpensive and available in most laboratories, showed to be useful for screening for problematic levels of drugs in WWTP effluents. It is known that several livestock and slaughterhouse effluents (pre-treated or treated) are discharged to the urban network before discharge into the environment. The presence of these drugs in such effluents can constitute a significant environmental problem that should be addressed, by the monitoring of these drugs and by implementation of methodologies that contribute to their decrease/elimination from wastewaters. Minocycline (≤6 μg L(-1)), oxytetracycline (≤7 μg L(-1)), tetracycline (≤6 μg L(-1)) and enrofloxacin (effluents. Detectable levels of enrofloxacin (effluents.

  3. Tannery Effluent Treatment by Yeast Species Isolates from Watermelon

    Directory of Open Access Journals (Sweden)

    Stanley Irobekhian Reuben Okoduwa

    2017-02-01

    Full Text Available The quest for an effective alternative means for effluent treatment is a major concern of the modern-day scientist. Fungi have been attracting a growing interest for the biological treatment of industrial wastewater. In this study, Saccharomycescerevisiae and Torulasporadelbrueckii were isolated from spoiled watermelon and inoculated into different concentrations of effluent. The inoculants were incubated for 21-days to monitor the performance of the isolates by measurement of biochemical oxygen demand (BOD, chemical oxygen demand (COD, nitrates, conductivity, phosphates, sulphates and turbidity. The results showed that Saccharomycescerevisiae had the highest percentage decrease of 98.1%, 83.0%, 60.7%, 60.5%, and 54.2% for turbidity, sulphates, BOD, phosphates and COD, respectively, of the tannery effluent. Torulasporadelbrueckii showed the highest percentage decrease of 92.9%, 90.6%, and 61.9% for sulphates, COD, and phosphates, respectively, while the syndicate showed the highest percentage reduction of 87.4% and 70.2% for nitrate and total dissolve solid (TDS, respectively. The least percentage decrease was displayed by syndicate organisms at 51.2%, 48.1% and 40.3% for BOD, COD and conductivity, respectively. The study revealed that Saccharomycescerevisiae and Torulasporadelbrueckii could be used in the biological treatment of tannery-effluent. Hence, it was concluded that the use of these organisms could contribute to minimizing the adverse environmental risks and health-hazards associated with the disposal of untreated tannery-effluents.

  4. Effect of surface treatment of tailings on effluent quality

    International Nuclear Information System (INIS)

    Murray, D.R.; Okuhara, D.

    1980-01-01

    Lysimeters containing 125 tons of mine tailings were used to determine the impact of gravel, sawdust, and vegetation as surface treatments on the quality and quantity of effluent produced from sulfide-containing uranium mill tailings. Over a 5-yr period, treatments did not alter the effluent quality to a level acceptable to regulatory requirements. The concentration of iron, copper, lead, aluminum, and sulfate increased with the rise of acidity during this period. However, the rate and extent of changes did vary with the treatment. The role of surface treatment in long-term waste abandonment must be investigated further

  5. Best Available Technology (BAT) guidance for radiological liquid effluents at US Department of Energy Facilities

    International Nuclear Information System (INIS)

    Wallo, A. III; Peterson, H.T. Jr.; Ikenberry, T.A.; Baker, R.E.

    1993-01-01

    The US Department of Energy (DOE), in DOE Order 5400.5 (1990), directs operators of DOE facilities to apply the Best Available Technology (BAT) to control radiological liquid effluents from these facilities when specific conditions are present. DOE has published interim guidance to assist facility operators in knowing when a BAT analysis is needed and how such an analysis should be performed and documented. The purpose of the guidance is to provide a uniform basis in determining BAT throughout DOE and to assist in evaluating BAT determinations during programmatic audits. The BAT analysis process involves characterizing the effluent source; identifying and selecting candidate control technologies; evaluating the potential environmental, operational, resource, and economic impacts of the control technologies; developing an evaluation matrix for comparing the technologies; selecting the BAT; and documenting the evaluation process. The BAT analysis process provides a basis for consistent evaluation of liquid effluent releases, yet allows an individual site or facility the flexibility to address site-specific issues or concerns in the most appropriate manner

  6. Monitoring of the radioactive liquid effluents discharged from IPEN-CNEN/SP. Optimization of the procedures adopted

    International Nuclear Information System (INIS)

    Seki, C.R.

    1990-01-01

    The main purpose of a radioactive liquid effluents monitoring of a nuclear installation is to determine the amount of radioactivity discharged to the environment, as well as, to verify if this activity is below the authorized discharge limits established by the competent authority. Although this control has been established on a routine basis since the beginning of operation of the nuclear installations available at IPEN, the growing of such facilities in the last years has implied in an increase in the number of samples to be analyzed. The aim of this work is, therefore, to optimize the procedures adopted in the Environmental Monitoring Division of IPEN-CNEN/SP for the activity measurement of the liquid effluents discharged to the environment. Since these effluents are discharged to Pinheiros river, which presents a high dilution factor, a study is also carried out in order to verify if the activity present can be measured by the equipment available. (author)

  7. British Nuclear Fuels plc's effluent plant services building

    International Nuclear Information System (INIS)

    Williams, L.

    1990-01-01

    The new Effluent Plant Services building (EPSB) on the Sellafield Nine Acre Site was built by Costain Engineering Limited for British Nuclear Fuels Limited. The EPSB is dedicated to a new generation of nuclear waste treatment plants, aimed at reducing discharges into the Irish Sea and other environmental impacts by removing actinides from liquid effluents and decontaminating waste solvents. This article describes the design, construction and operation of the plant. (UK)

  8. A Novel Methylotrophic Bacterial Consortium for Treatment of Industrial Effluents.

    Science.gov (United States)

    Hingurao, Krushi; Nerurkar, Anuradha

    2018-01-01

    Considering the importance of methylotrophs in industrial wastewater treatment, focus of the present study was on utilization of a methylotrophic bacterial consortium as a microbial seed for biotreatment of a variety of industrial effluents. For this purpose, a mixed bacterial methylotrophic AC (Ankleshwar CETP) consortium comprising of Bordetella petrii AC1, Bacillus licheniformis AC4, Salmonella subterranea AC5, and Pseudomonas stutzeri AC8 was used. The AC consortium showed efficient biotreatment of four industrial effluents procured from fertilizer, chemical and pesticide industries, and common effluent treatment plant by lowering their chemical oxygen demand (COD) of 950-2000 mg/l to below detection limit in 60-96 h in 6-l batch reactor and 9-15 days in 6-l continuous reactor. The operating variables of wastewater treatment, viz. COD, BOD, pH, MLSS, MLVSS, SVI, and F/M ratio of these effluents, were also maintained in the permissible range in both batch and continuous reactors. Therefore, formation of the AC consortium has led to the development of an efficient microbial seed capable of treating a variety of industrial effluents containing pollutants generated from their respective industries.

  9. Introduction to Effluent Treatment and Industrial Methods

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 5; Issue 11. Techniques of WasteWater Treatment - Introduction to Effluent Treatment and Industrial Methods. Amol A Kulkarni Mugdha Deshpande A B Pandit. General Article Volume 5 Issue 11 November 2000 pp 56-68 ...

  10. Safety evaluation of liquid radioactive effluents treatment system in a BWR reactor, through the LIQM03 code

    International Nuclear Information System (INIS)

    Zorrilla R, S.H.

    1978-01-01

    In this work we made a safety evaluation of the liquid radioactive effluents system in a plant using a BWR similar to that now installed in Laguna Verde. For that purpose, the computation program ORIGENwas modified, in order to keep up to date and adapt it to the PDP 10 computer, which is operating at the Computation Department of the Nuclear Center of Mexico, the code LIQM03 was the result of this modification. As usual in this work we dealt with problems which were solved opportunely, now we have at our disposal the code LIQM03 which will be in the future a very useful tool for this kind of evaluations. (author)

  11. Free Moisture in GT-73 Resin Waste Generated from the Effluent Treatment Facility

    International Nuclear Information System (INIS)

    Kaplan, D.I.

    2002-01-01

    Solid Waste Division is presently evaluating whether to transfer spent resin generated from the Effluent Treatment Facility (ETF) to the Nevada Test Site (NTS). One of the criteria for the waste to be accepted at the NTS is that the waste must not contain more than 1 vol-percent free liquid. This criterion reduces the amount of liquid, a primary vector for subsurface contaminant migration (along with colloids), introduced into the repository. This criterion also serves to reduce the chance of an accidental spill during transport of the waste to the NTS. On December 15, 1997, a shipment from Fernald to the NTS leaked some liquid waste onto a highway in Kingman, Arizona, resulting in a Type B Accident Investigation. The direct cause of the leak was attributed to broken welds related to the use of substandard containers. The overall objective of this study was to provide guidance as to whether the spent GT-73 resin would meet the free moisture WAC set by the NTS

  12. Study of technical and economical feasibility for implementation of a movable unit for treatment of industrial effluents with electron beam

    International Nuclear Information System (INIS)

    Rela, Carolina Sciamarelli

    2006-01-01

    The treatment of industrial effluents is a practice that is disseminating in accelerated rhythm, of contributing to reinforce the public image, through the combat of the pollution, it brings economical advantages allowing the companies the reuse of the treated water in their own processes. The liquid effluent treatment technique studied in the present work is the one that uses the chemical oxidation/reduction standing out the use of the electron beam (e.b.) radiation. This technique uses an advanced oxidation process, generating radicals highly reagents that provoke the oxidation, reduction, dissociation and degradation in composed organic and exercising lethal effect in general in the microorganisms and parasites. In this work a conceptual and basic project of a movable unit of effluents treatment using electron beam radiation process was developed, in order that the unit moves until the treatment point, where the effluent is produced, facilitating the logistics. A technical and economical feasibility study was also elaborated allowing data on the capacity and cost of effluents processing to consolidate the values of the necessary investments to be presented to foundations organs for the construction of a movable unit. The results of the studies demonstrated that it is technically viable attending the pertinent legislation of Brazil, in the aspects of Radiation Protection and transport limit capacity. The unitary cost of the e.b. radiation processing in the movable unit was shown more expensive than in the fixed unit, the reason is the decrease of the efficiency of the interaction of the incident electrons in the effluent, due to the reduction of electron energy operation time of the unit. (author)

  13. Two stage treatment of dairy effluent using immobilized Chlorella pyrenoidosa

    Science.gov (United States)

    2013-01-01

    Background Dairy effluents contains high organic load and unscrupulous discharge of these effluents into aquatic bodies is a matter of serious concern besides deteriorating their water quality. Whilst physico-chemical treatment is the common mode of treatment, immobilized microalgae can be potentially employed to treat high organic content which offer numerous benefits along with waste water treatment. Methods A novel low cost two stage treatment was employed for the complete treatment of dairy effluent. The first stage consists of treating the diary effluent in a photobioreactor (1 L) using immobilized Chlorella pyrenoidosa while the second stage involves a two column sand bed filtration technique. Results Whilst NH4+-N was completely removed, a 98% removal of PO43--P was achieved within 96 h of two stage purification processes. The filtrate was tested for toxicity and no mortality was observed in the zebra fish which was used as a model at the end of 96 h bioassay. Moreover, a significant decrease in biological oxygen demand and chemical oxygen demand was achieved by this novel method. Also the biomass separated was tested as a biofertilizer to the rice seeds and a 30% increase in terms of length of root and shoot was observed after the addition of biomass to the rice plants. Conclusions We conclude that the two stage treatment of dairy effluent is highly effective in removal of BOD and COD besides nutrients like nitrates and phosphates. The treatment also helps in discharging treated waste water safely into the receiving water bodies since it is non toxic for aquatic life. Further, the algal biomass separated after first stage of treatment was highly capable of increasing the growth of rice plants because of nitrogen fixation ability of the green alga and offers a great potential as a biofertilizer. PMID:24355316

  14. Waste treatment

    International Nuclear Information System (INIS)

    Davies, D.; Hooper, E.W.

    1981-01-01

    In the treatment of wastes, such as liquid radioactive effluents, it is known to remove radionuclides by successive in situ precipitation of cobalt sulphide, an hydroxide, barium sulphate and a transition element ferrocyanide, followed by separation of the thereby decontaminated effluent. In this invention, use is made of precipitates such as obtained above in the treatment of further fresh liquid radioactive effluent, when it is found that the precipitates have additional capacity for extracting radionuclides. The resulting supernatant liquor may then be subjected to a further precipitation treatment such as above. Decontamination factors for radionuclides of Ce, Ru, Sr and Cs have been considerably enhanced. (author)

  15. PFOS and PFOA in influents, effluents, and biosolids of Chinese wastewater treatment plants and effluent-receiving marine environments

    International Nuclear Information System (INIS)

    Chen Hong; Zhang Can; Han Jianbo; Yu Yixuan; Zhang Peng

    2012-01-01

    Concentrations of perfluorooctane sulfonate (PFOS) and perfluorooctanoate (PFOA) in influents, effluents and sludges were investigated by analyzing the samples from twelve wastewater treatment plants (WWTPs) in China. The highest concentrations of PFOS and PFOA in influents were found to occur in municipal and industrial WWTPs, respectively. Relative to PFOS and PFOA concentrations in influents, elevated concentrations were observed in effluents from WWTPs applying anaerobic–anoxic–oxic wastewater treatment process. Importantly, application of previously reported organic carbon normalized partition coefficients (K OC ) derived from sediment-based sorption experiments appear to underestimate the PFOS and PFOA levels in biosolids quantified in the current study. PFOS and PFOA levels in effluents were found to be approximately 27 and 2 times higher than those detected in the effluent-receiving seawater, respectively. However, their levels in this area of seawater haven't exceeded the provisional short-term health advisories in drinking water issued by U.S. EPA yet. - Highlights: ► Levels of PFOS and PFOA in influents, effluents and sludge from Chinese WWTPs were examined. ► Municipal sewage was the main source for PFOS in Chinese WWTPs, while industrial sewage for PFOA. ► PFOS and PFOA concentrations in effluents were much higher than those in receiving seawater. - Levels of PFOS and PFOA in influent, effluent and sludge samples from Chinese WWTPs were examined and found much higher than those in receiving seawater.

  16. 40 CFR 417.163 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SOAP AND DETERGENT MANUFACTURING POINT SOURCE CATEGORY Manufacture of Liquid Detergents Subcategory § 417.163 Effluent limitations guidelines representing the degree... subpart after application of the best available technology economically achievable: (a) For normal liquid...

  17. The effects of Niger State water treatment plant effluent on its ...

    African Journals Online (AJOL)

    The effect of water treatment plant effluent on its receiving river (Kaduna) was examined. Samples were collected from the effluents discharge from Chanchaga water treatment plant into upstream and down stream of the receiving river monthly for six month. Samples were analyzed in the laboratory for microbial counts and ...

  18. Efficiency Evaluation of Filtration with Fluidized Bed for Treatment of Secondary Effluents for Reuse

    OpenAIRE

    Mohammad Hosaini; Rohallah Moradi; Gholam Hossain Safari

    2013-01-01

    Background & Objectives: Recently, deficient in atmospheric drop and discharges of wastewater effluents leads to serious threat for water resource. For that reason, for prevention of water source pollution and also reuse of wastewater effluents, treatment of such effluents seems to be necessary. Methods: In this work, fluidized bed reactor with a filter was used for treatment of effluents from Shahrak Gharb wastewater treatment plant. Various parameters such as BOD5, COD, TS, TP, TN and t...

  19. Disposal of Low-Activity Liquid Effluents by Dilution

    Energy Technology Data Exchange (ETDEWEB)

    Bovard, P.; Candillon, C. [Atomic Energy Commission, Saclay (France)

    1960-07-01

    Nuclear centres are frequently faced with problems of disposal of sizeable quantities of low-activity liquid effluents. Under present conditions the most practicable solution seems to be to discharge them into a natural or artificial water system, so as to dilute them as much as possible and thus reduce their radioactive isotope content below the public health levels. This technique is employed by all nuclear centres in France, which use the following convenient outlets: Saclay: the artificial ponds made by Louis XIV to feed the great Versailles fountains; Fontenay-aux-Roses: the Paris sewer system; Grenoble: the river Isere; Marcoule: the river Rhone. Until 1957 the amount of waste was negligible. It is still very slight at the first three centres, only a few dozen millicuries a month. At Marcoule the activity of the effluents is somewhat greater, but the Rhone's rate of flow ensures a very low final content of radioactive elements. The increasing discharge of wastes into river systems calls for a close watch on changes in radioactivity in the environment (i.e. in air, water and soil), and especially on areas in which radioactive isotopes may accumulate. We have therefore made laboratory studies of the mechanics of radioactivity concentration, in order to improve our sampling methods and ascertain the movement of wastes.

  20. Treatment of radioactive effluents at the Boris Kidric Institute

    International Nuclear Information System (INIS)

    Bojovic, P.; Drobnik, S.; Popara, D.

    1964-10-01

    The paper describes the origin, composition and activity of radioactive effluents at the Boris Kidric Institute, their collection at the places or origin, transport to the place of disposal and treatment of some smaller quantities. Special attention has been paid to effluents with short-lived isotopes produced in the Laboratory for radioactive isotope production (author)

  1. Extraction of metals from liquid effluent using modified inorganic ion exchangers

    International Nuclear Information System (INIS)

    Hudson, M.J.

    1993-01-01

    Inorganic ion exchangers such as goethite, titanium (IV) oxide; silica and zeolites have been modified to examine the extraction of ruthenium; technetium and cobalt from liquid effluent. In addition, tin (IV) hydrogenphosphate and antimony hydrogenphosphate have been also examined in the modified and unmodified forms. It has been shown that some of the above reagents are able to remove the required metal ions from aqueous solution at the trace and mg L -1 levels. (author)

  2. Study of sample-detector assemblies for application to in-situ measurement of radioactivity in liquid effluents

    International Nuclear Information System (INIS)

    Pendharkar, K.A.; Narayanan Kutty, K.; Krishnamony, S.

    1991-01-01

    This paper describes the experimental investigations carried out on four different types of sample-detector assemblies with a view to determining their detection limits and relative merits for application to in-situ measurement of radioactivity in liquid effluents. The four systems studied were: (1) gamma detection using 11 cm x 8 cm NaI (Tl) scintillation detector inserted in the cavity of a specially designed stainless steel chamber of capacity 15 liters, (2) gamma detection using a metal-walled G.M. counter in a similar manner, (3) beta detection using twin thin-walled G.M. counters immersed in liquid, and (4) end window G.M. counter positioned above the liquid surface in a shallow tray. The design features of an in-line monitor employing a 11 cm x 8 cm NaI (Tl) detector used for the routine monitoring of beta gamma activity concentrations in the low level effluents of the Tarapur Fuel Processing Plant are described. (author). 1 tab

  3. Continuously tritium monitoring of the pipe of liquid effluents at the Cea Cadarache

    International Nuclear Information System (INIS)

    Pira, Y.

    2004-01-01

    This report is oriented toward the radiation protection of environment that is an essential component of radiation protection. It is necessary to detect any solid, liquid or gaseous abnormal release and to find its origin. The present study bears on a detection instrument in continuously to find tritium in liquid effluents of the Cea Cadarache. After having study the functioning principle of this device, an evaluation of its performances has been realised ( back noise, yield, detection limit) and to a checking in real conditions of utilization. (N.C.)

  4. Method and apparatus for treating gaseous effluents from waste treatment systems

    Science.gov (United States)

    Flannery, Philip A.; Kujawa, Stephan T.

    2000-01-01

    Effluents from a waste treatment operation are incinerated and oxidized by passing the gases through an inductively coupled plasmas arc torch. The effluents are transformed into plasma within the torch. At extremely high plasma temperatures, the effluents quickly oxidize. The process results in high temperature oxidation of the gases without addition of any mass flow for introduction of energy.

  5. Treatment of emerging contaminants in wastewater treatment plants (WWTP) effluents by solar photocatalysis using low TiO2 concentrations

    International Nuclear Information System (INIS)

    Prieto-Rodriguez, L.; Miralles-Cuevas, S.; Oller, I.; Agüera, A.; Puma, G. Li; Malato, S.

    2012-01-01

    Highlights: ► Low TiO 2 concentration suitable for removal of contaminants in WWTP effluents. ► The low concentration of TiO 2 limits the reaction rate due to the loss of photons. ► Contaminant degradation >85% is possible after a certain reaction time. ► New developments in CPC photoreactors with as large an O.D. are necessary. - Abstract: The optimal photocatalyst concentration for industrial wastewater treatment in current photoreactor designs is several hundreds of milligrams per liter. However, the elimination of emerging contaminants (ECs), which are present at extremely low concentrations in waste water treatment plants (WWTP) effluents might be accomplished at much lower catalyst (TiO 2 ) concentrations. One of the main drawbacks of reducing catalyst loading below the optimum is the loss of useful photons which instead are transmitted through the TiO 2 suspension without being absorbed by the catalyst. Accordingly, in this work, laboratory and solar pilot-scale experiments were performed with real WWTP effluents to evaluate the kinetics of photocatalytic degradation of 52 emerging contaminants under realistic (ppb) concentrations. The analysis of the samples was accomplished by solid phase extraction (SPE) followed by liquid chromatography–mass spectrometry (LC–MS). In view of the results, low concentrations of TiO 2 of the order of tens of milligrams per liter were found to be insufficient for the degradation of the ECs in photoreactors with a short light-path length (29 cm). However, it was established that solar reactors of diameters of several hundreds of millimetres could be used for the efficient removal of ECs from WWTP effluents. The results presented show a general methodology for selecting the most efficient reactor diameter on the basis of the desired catalyst concentration.

  6. Derived release limits (DRL's) for airborne and liquid effluents from the Chalk River Nuclear Laboratories during normal operations

    International Nuclear Information System (INIS)

    Palmer, J.F.

    1981-02-01

    Derived release limits (DRL's), based on regulatory dose limits, have been calculated for routine discharges of radioactivity in airborne and liquid effluents from the Chalk River Nuclear Laboratories. Three types of sources of airborne effluents were considered: the NRX/NRU stack, the 61 m stack connected to the 99 Mo production facility, and a roof vent typical of those installed on several buildings on the site. Sources of liquid effluents to the Ottawa River were treated as a single source from the site as a whole. Various exposure pathways to workers on the site and to members of the public outside the site boundary were considered in the calculations. The DRL's represent upper limits for routine emissions of radioactivity from the Chalk River Nuclear Laboratories to the surrounding environment. Actual releases are regulated by Administrative Levels, set lower than the DRL's, and are confirmed by monitoring. (author)

  7. Annual report on the effluent control of low level liquid water in Tokai Works. FY2004

    International Nuclear Information System (INIS)

    Takeishi, Minoru; Miyagawa, Naoto; Watanabe, Hitoshi

    2005-08-01

    This report was written about the effluent control of low level liquid waste in JNC Tokai Works Fiscal Year 2004, from 1st April 2004 to 31th March 2005. In this period, the quantities and concentrations of radioactivity in liquid waste from Tokai Works were under the discharge limits of 'Safety Regulations for the Tokai Reprocessing Plant' and regulations of government. (author)

  8. Comparison of different liquid anaerobic digestion effluents as inocula and nitrogen sources for solid-state batch anaerobic digestion of corn stover

    International Nuclear Information System (INIS)

    Xu Fuqing; Shi Jian; Lv Wen; Yu Zhongtang; Li Yebo

    2013-01-01

    Highlights: ► Compared methane production of solid AD inoculated with different effluents. ► Food waste effluent (FWE) had the largest population of acetoclastic methanogens. ► Solid AD inoculated with FWE produced the highest methane yield at F/E ratio of 4. ► Dairy waste effluent (DWE) was rich of cellulolytic and xylanolytic bacteria. ► Solid AD inoculated with DWE produced the highest methane yield at F/E ratio of 2. - Abstract: Effluents from three liquid anaerobic digesters, fed with municipal sewage sludge, food waste, or dairy waste, were evaluated as inocula and nitrogen sources for solid-state batch anaerobic digestion of corn stover in mesophilic reactors. Three feedstock-to-effluent (F/E) ratios (i.e., 2, 4, and 6) were tested for each effluent. At an F/E ratio of 2, the reactor inoculated by dairy waste effluent achieved the highest methane yield of 238.5 L/kgVS feed , while at an F/E ratio of 4, the reactor inoculated by food waste effluent achieved the highest methane yield of 199.6 L/kgVS feed . The microbial population and chemical composition of the three effluents were substantially different. Food waste effluent had the largest population of acetoclastic methanogens, while dairy waste effluent had the largest populations of cellulolytic and xylanolytic bacteria. Dairy waste also had the highest C/N ratio of 8.5 and the highest alkalinity of 19.3 g CaCO 3 /kg. The performance of solid-state batch anaerobic digestion reactors was closely related to the microbial status in the liquid anaerobic digestion effluents.

  9. Comparison of different liquid anaerobic digestion effluents as inocula and nitrogen sources for solid-state batch anaerobic digestion of corn stover

    Energy Technology Data Exchange (ETDEWEB)

    Xu Fuqing; Shi Jian [Department of Food, Agricultural and Biological Engineering, Ohio State University, Ohio Agricultural Research and Development Center, 1680 Madison Ave., Wooster, OH 44691 (United States); Lv Wen; Yu Zhongtang [Department of Animal Sciences, Ohio State University, Columbus, OH 43210 (United States); Li Yebo, E-mail: li.851@osu.edu [Department of Food, Agricultural and Biological Engineering, Ohio State University, Ohio Agricultural Research and Development Center, 1680 Madison Ave., Wooster, OH 44691 (United States)

    2013-01-15

    Highlights: Black-Right-Pointing-Pointer Compared methane production of solid AD inoculated with different effluents. Black-Right-Pointing-Pointer Food waste effluent (FWE) had the largest population of acetoclastic methanogens. Black-Right-Pointing-Pointer Solid AD inoculated with FWE produced the highest methane yield at F/E ratio of 4. Black-Right-Pointing-Pointer Dairy waste effluent (DWE) was rich of cellulolytic and xylanolytic bacteria. Black-Right-Pointing-Pointer Solid AD inoculated with DWE produced the highest methane yield at F/E ratio of 2. - Abstract: Effluents from three liquid anaerobic digesters, fed with municipal sewage sludge, food waste, or dairy waste, were evaluated as inocula and nitrogen sources for solid-state batch anaerobic digestion of corn stover in mesophilic reactors. Three feedstock-to-effluent (F/E) ratios (i.e., 2, 4, and 6) were tested for each effluent. At an F/E ratio of 2, the reactor inoculated by dairy waste effluent achieved the highest methane yield of 238.5 L/kgVS{sub feed}, while at an F/E ratio of 4, the reactor inoculated by food waste effluent achieved the highest methane yield of 199.6 L/kgVS{sub feed}. The microbial population and chemical composition of the three effluents were substantially different. Food waste effluent had the largest population of acetoclastic methanogens, while dairy waste effluent had the largest populations of cellulolytic and xylanolytic bacteria. Dairy waste also had the highest C/N ratio of 8.5 and the highest alkalinity of 19.3 g CaCO{sub 3}/kg. The performance of solid-state batch anaerobic digestion reactors was closely related to the microbial status in the liquid anaerobic digestion effluents.

  10. Liquid effluent FY 1996 program plan WBS 1.2.2.1. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-09-01

    The Liquid Effluents Program supports the three Hanford Site mission components: (1) Clean up the site, (2) provide scientific and technological excellence to meet global needs, and (3) Partner in the economic diversification of the region. Nine Hanford Site objectives have been established for the Hanford Site programs to accomplish all three components of this mission.

  11. Liquid effluent FY 1996 program plan WBS 1.2.2.1. Revision 1

    International Nuclear Information System (INIS)

    1995-09-01

    The Liquid Effluents Program supports the three Hanford Site mission components: (1) Clean up the site, (2) provide scientific and technological excellence to meet global needs, and (3) Partner in the economic diversification of the region. Nine Hanford Site objectives have been established for the Hanford Site programs to accomplish all three components of this mission

  12. Activated sludge and activated carbon treatment of a wood preserving effluent containing pentachlorophenol

    National Research Council Canada - National Science Library

    Guo, P. H. M

    1980-01-01

    ...; however, PCP removal averaged only 35% and the effluent was toxic to rainbow trout. Treatment of the activated sludge effluent by carbon adsorption resulted in effective PCP removal and non-toxic effluents...

  13. Radioactive tracer method as an instrument for testing effectiveness of effluent treatment installations and mixing patterns in natural streams

    Energy Technology Data Exchange (ETDEWEB)

    Szpilowski, S; Strzelczak, G; Winnicki, R [Institute of Nuclear Research, Warsaw (Poland)

    1976-01-01

    The radiotracer methods of evaluation of sewage flow rate, testing of effluent treatment plants and mixing patterns in natural streams have been described. Experimental works were carried out for industrial installations and natural streams. As a tracer of liquid phase an aqueous KBr solution labelled with /sup 82/Br have been used. The sediment materials have been labelled with /sup 198/Au in the form of colloidal gold. The results of investigations have been utilized for treatment process analysis and water pollution control.

  14. The effects of Niger State water treatment plant effluent on its ...

    African Journals Online (AJOL)

    STORAGESEVER

    2008-05-16

    May 16, 2008 ... The effect of water treatment plant effluent on its receiving river (Kaduna) was examined. Samples were ... Agency (FEPA) limits for effluent discharge into surface water. .... municipal sewage, garbages, domestic and industrial.

  15. Treatment of effluents from the nuclear fuel cycle reconversion stage

    International Nuclear Information System (INIS)

    Ladeira, Ana C.Q.; Morais, Carlos A.; Goncalves, Joao S.; Souza, Pedro de

    2007-01-01

    The conversion of uranium hexafluoride (UF 6 ) into uranium dioxide (UO 2 ) takes place in Resende (RJ) at the Nuclear Fuel Factory - FCN. The process generates liquid effluents with significant concentrations of uranium which might be treated before being discharged into the environment. This work is aimed at the recovery of uranium from two distinct liquid effluents; one with high carbonate content and the other with elevated fluoride concentration. It is also presented a study about carbonate removal from an effluent that consists of water - methanol solution generated during the filtration step of the ammonium uranyl tricarbonate (AUT). The results showed that (1) the uranium from the carbonated solution can be recovered through the ion exchange technique using the strong base anionic resin IRA 910-U since carbonate has been removed as CO 2 after heating; (2) the most suitable technique to recover uranium from the fluoride solution is by precipitation as (NH 4 ) 2 UO 4 F 2 - ammonium fluorouranate peroxide (APOFU), (3) the solution free of carbonate can be added to the fluoride solution and the uranium from the final solution can be recovered by precipitation as ammonium fluorouranate peroxide as well; (4) the carbonate from the water-methanol solution can be recovered as calcium carbonate through the addition of calcium chloride or it can be removed through the addition of sulfuric acid. The product formed by adding sulfuric acid is ammonium sulfate and might be used as fertilizer. (author)

  16. Effluent treatment options for nuclear thermal propulsion system ground tests

    International Nuclear Information System (INIS)

    Shipers, L.R.; Brockmann, J.E.

    1992-01-01

    A variety of approaches for handling effluent from nuclear thermal propulsion system ground tests in an environmentally acceptable manner are discussed. The functional requirements of effluent treatment are defined and concept options are presented within the framework of these requirements. System concepts differ primarily in the choice of fission-product retention and waste handling concepts. The concept options considered range from closed cycle (venting the exhaust to a closed volume or recirculating the hydrogen in a closed loop) to open cycle (real time processing and venting of the effluent). This paper reviews the strengths and weaknesses of different methods to handle effluent from nuclear thermal propulsion system ground tests

  17. Study about the integrated treatment of chemical and radioactive effluents, introducing the zero release concept

    International Nuclear Information System (INIS)

    Mierzwa, Jose Carlos

    1996-01-01

    An Integrated System to the treatment of Chemical and Radioactive Effluents to the Centro Experimental Aramar is proposed and evaluated, introducing the Effluent Zero Release concept, where factors related to the environmental regulation in vigor in the country, as well as the availability of hydrological resources in the place where CEA have been implanted, are considered. Through a literature analysis of the main effluents treatment techniques available nowadays and after a case of study selection, take into account two industrial installations that will be implanted at CEA, it was defined an arrangement to compose the Integrated System to the Treatment of Chemicals and Radioactive Effluents, focusing the Zero Release concept consolidation. A defined arrangement uses a combination among three treatment processes, it means chemical precipitation, reverse osmosis and evaporation, that were experimentally evaluated. The proposed arrangement was evaluated using synthetic effluents, that were prepared based on data from literature and conception documents of the installation considered in this work. Three kinds of effluents were simulated, one arising from a nuclear reactor laundry, one arising from the water refrigeration system and demineralized water production to the nuclear reactor and the other one arising from a nuclear material production laboratory. Each effluent were individually submitted to the selected treatment processes, to get the best operational conditions for each treatment process. The results got during the laboratory assays show that the proposed Integrated System to the Treatment of Chemicals and Radioactive Effluents is feasible, consolidating the Effluent Zero Release concept, which is the proposition of this work. (author)

  18. Treatment of radioactive liquid effluents by reverse osmosis membranes: From lab-scale to pilot-scale.

    Science.gov (United States)

    Combernoux, Nicolas; Schrive, Luc; Labed, Véronique; Wyart, Yvan; Carretier, Emilie; Moulin, Philippe

    2017-10-15

    The recent use of the reverse osmosis (RO) process at the damaged Fukushima-Daiichi nuclear power plant generated a growing interest in the application of this process for decontamination purposes. This study focused on the development of a robust RO process for decontamination of two kinds of liquid effluents: a contaminated groundwater after a nuclear disaster and a contaminated seawater during a nuclear accident. The SW30 HR membrane was selected among other in this study due to higher retentions (96% for Cs and 98% for Sr) in a true groundwater. Significant fouling and scaling phenomenon, attributed to calcium and strontium precipitation, were evidenced in this work: this underscored the importance of the lab scale experiment in the process. Validation of the separation performances on trace radionuclides concentration was performed with similar retention around 96% between surrogates Cs (inactive) and 137 Cs (radioactive). The scale up to a 2.6 m 2 spiral wound membrane led to equivalent retentions (around 96% for Cs and 99% for Sr) but lower flux values: this underlined that the hydrodynamic parameters (flowrate/cross-flow velocity) should be optimized. This methodology was also applied on the reconstituted seawater effluent: retentions were slightly lower than for the groundwater and the same hydrodynamic effects were observed on the pilot scale. Then, ageing of the membrane through irradiation experiments were performed. Results showed that the membrane active layer composition influenced the membrane resistance towards γ irradiation: the SW30 HR membrane performances (retention and permeability) were better than the Osmonics SE at 1 MGy. Finally, to supplement the scale up approach, the irradiation of a spiral wound membrane revealed a limited effect on the permeability and retention. This indicated that irradiation conditions need to be controlled for a further development of the process. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Pulp and paper mill effluent treatments have differential endocrine-disrupting effects on rainbow trout.

    Science.gov (United States)

    Orrego, Rodrigo; Guchardi, John; Hernandez, Victor; Krause, Rachelle; Roti, Lucia; Armour, Jeffrey; Ganeshakumar, Mathumai; Holdway, Douglas

    2009-01-01

    Endocrine disruption (ED) effects due to pulp and paper mill effluents extracts involving different industrial procedures and effluent treatments (nontreated, primary, and secondary treated) were evaluated using immature triploid rainbow trout in a pulse-exposure toxicity experiment. The protocol involved the use of intraperitoneal injection of mill extracts (solid-phase extraction [SPE]) corrected for individual fish weight and included several laboratory standards (steroidal hormones and phytosterols). Biological endpoints at two different levels of biological organization were analyzed (molecular and individual organism). Results indicated that nonsignificant changes were observed in the individual physiological indices represented by condition factor, liver somatic index, and gonad somatic index during the experiment. Significant induction of liver ethoxyresorufin-O-deethylase activity was observed between different effluent treatments and experimental controls. Significant endocrine-disrupting effects at the reproductive level were observed in all effluent treatments involving significant increments in plasma vitellogenin (VTG) levels. Fish exposed to untreated effluent extracts had significantly higher VTG levels compared to fish exposed to primary and secondary treatment effluent extracts, indicating a decrease of the estrogenic effect due to the effluent treatment. The present study has shown that for the Chilean pulp and paper mill SPE extracts evaluated, an endocrine disruption effect was induced in immature triploid rainbow, reaffirming the significant estrogenic effects demonstrated previously in laboratory and field experiments.

  20. Calculation of releases of radioactive materials in gaseous and liquid effluents from boiling water reactors (BWR-GALE Code)

    International Nuclear Information System (INIS)

    Bangart, R.L.; Bell, L.G.; Boegli, J.S.; Burke, W.C.; Lee, J.Y.; Minns, J.L.; Stoddart, P.G.; Weller, R.A.; Collins, J.T.

    1978-12-01

    The calculational procedures described in the report reflect current NRC staff practice. The methods described will be used in the evaluation of applications for construction permits and operating licenses docketed after January 1, 1979, until this NUREG is revised as a result of additional staff review. The BWR-GALE (Boiling Water Reactor Gaseous and Liquid Effluents) Code is a computerized mathematical model for calculating the release of radioactive material in gaseous and liquid effluents from boiling water reactors (BWRs). The calculations are based on data generated from operating reactors, field tests, laboratory tests, and plant-specific design considerations incorporated to reduce the quantity of radioactive materials that may be released to the environment

  1. Facility effluent monitoring plan for the 325 Facility

    International Nuclear Information System (INIS)

    1998-01-01

    The Applied Chemistry Laboratory (325 Facility) houses radiochemistry research, radioanalytical service, radiochemical process development, and hazardous and mixed hazardous waste treatment activities. The laboratories and specialized facilities enable work ranging from that with nonradioactive materials to work with picogram to kilogram quantities of fissionable materials and up to megacurie quantities of other radionuclides. The special facilities include two shielded hot-cell areas that provide for process development or analytical chemistry work with highly radioactive materials, and a waste treatment facility for processing hazardous, mixed, low-level, and transuranic wastes generated by Pacific Northwest Laboratory. Radioactive material storage and usage occur throughout the facility and include a large number of isotopes. This material is in several forms, including solid, liquid, particulate, and gas. Some of these materials are also heated during testing which can produce vapors. The research activities have been assigned to the following activity designations: High-Level Hot Cell, Hazardous Waste Treatment Unit, Waste Form Development, Special Testing Projects, Chemical Process Development, Analytical Hot Cell, and Analytical Chemistry. The following summarizes the airborne and liquid effluents and the results of the Facility Effluent Monitoring Plan (FEMP) determination for the facility. The complete monitoring plan includes characterization of effluent streams, monitoring/sampling design criteria, a description of the monitoring systems and sample analysis, and quality assurance requirements

  2. Bromide as chemical tracer to measure the liquid effluent flow at IPEN-CNEN/SP

    International Nuclear Information System (INIS)

    Silva, Douglas B.; Faustino, Mainara G.; Monteiro, Lucilena R.; Cotrim, Marycel E.B.; Pires, Maria Aparecida F.

    2013-01-01

    Due to recent changes in CONAMA Resolution 357, which occurred through the publication of Resolution 430, on May 13, 2011 that now set standards about the effluent release, IPEN-CNEN/SP initiated several actions to improve the Environmental Monitoring Program (PMA-Q) of stable chemical compounds. Besides various parameters (physical and chemical) established by CONAMA, the submission of an annual pollution inventory report became necessary. The liquid effluent flow measurement is required to implement this inventory. Thereby, this paper describes a study that uses bromide as a chemical tracer. This paper presents the results of 6 tracer releases in IPEN wastewater collection network between 2011 and 2012. Two tracer releases designs were performed: single pulse and continuous releases performed with 1 to 6 hours duration, done by using one single piston pump manufactured by DIONEX. After the release, one fraction of the effluent was collected every 15 minutes at IPEN effluent monitoring station. The tracer concentration in the effluent was analyzed by ion chromatography and flow was calculated considering the dilution in the system and pump flow set up for the release. The flow values were measured in 6 events were determined and evaluated as per Brazilian regulation requirements. Experimental designs to be implemented during 2013 monitoring were also discussed in this paper, contributing to legal compliance and to improve IPEN's Environmental Monitoring Program for stable chemical compounds (PMA-Q). (author)

  3. French practice and trends in the treatment and conditioning of PWR liquid effluents and solid wastes

    International Nuclear Information System (INIS)

    Celeri, J.J.; Pottier, P.; Sousselier, Y.

    1982-01-01

    From the early stages of the development of the nuclear industry in France, it has been decided to avoid radioactive effluent release by treatment, conditioning and storage of the wastes. It was not possible, when choosing this option, to reach the optimum from the beginning for the whole management system. The selection of a treatment process requires a precise knowledge of the nature, the composition and the arisings of radioactive wastes and these data are only available when commercial size reactors are in operation. To solve this problem, a close collaboration has been developed between the nuclear station operators and the R and D laboratories in charge of studying new treatment methods. This cooperation is a fruitful permanent exchange giving precise data about the waste, results of treatment operation on the industrial units, allowing modification in the installations to improve their efficiency and sometimes, resulting in new trends for the research program

  4. Methanization of industrial liquid effluents

    International Nuclear Information System (INIS)

    Frederic, S.; Lugardon, A.

    2007-01-01

    In a first part, this work deals with the theoretical aspects of the methanization of the industrial effluents; the associated reactional processes are detailed. The second part presents the technological criteria for choosing the methanization process in terms of the characteristics of the effluent to be treated. Some of the methanization processes are presented with their respective advantages and disadvantages. At last, is described the implementation of an industrial methanization unit. The size and the main choices are detailed: the anaerobic reactor, the control, the valorization aspects of the biogas produced. Some examples of industrial developments illustrate the different used options. (O.M.)

  5. Dragon Fruit Foliage Plant-Based Coagulant for Treatment of Concentrated Latex Effluent: Comparison of Treatment with Ferric Sulfate

    Directory of Open Access Journals (Sweden)

    Juferi Idris

    2013-01-01

    Full Text Available The effectiveness of dragon fruit foliage as a natural coagulant for treatment of concentrated latex effluent was investigated and compared with ferric sulfate, a chemical coagulant. Dragon fruit is a round and often red-colored fruit with scales-like texture and is native to south American countries which is also cultivated and heavily marketed in southeast Asian countries. Its foliage represents a part of its overall plant system. Latex effluent is one of the main byproduct from rubber processing factories in Malaysia. Three main parameters investigated were chemical oxygen demand (COD, suspended solids (SS, and turbidity of effluent. Coagulation experiments using jar test were performed with a flocculation system where the effects of latex effluent pH as well as coagulation dosage on coagulation effectiveness were examined. The highest recorded COD, SS, and turbidity removal percentages for foliage were observed for effluent pH 10 at 94.7, 88.9, and 99.7%, respectively. It is concluded that the foliage showed tremendous potential as a natural coagulant for water treatment purposes. The foliage could be used in the pretreatment stage of Malaysian latex effluent prior to secondary treatment.

  6. Chromium removal from tanning industries effluents

    International Nuclear Information System (INIS)

    Chaudry, M.A.; Ahmad, S.

    1997-01-01

    Air and water are the basic needs of human being and other living entities on the earth. Tanning industry uses water and some chemicals and so creates environmental problems, depending basically on two principal sources, hide and water. The processes of tanning are based on chromium sulphate and vegetable treatment of hide. According to the national environmental quality standards (NEQS) the effluent or disposed water should contain phenol less than 0.5 ppm, Cr, sulphates, chloride and other salts content. About 30-40 liters of water are used to process one Kg of raw hide into finished goods. Total installed capacity of hides and skins chrome tanning is 53.5 million square meter, earning a large amount of foreign exchange for our country. In the present work, seven tanning industries effluents from the suburbs of Multan city have been collected and analysed. The pH of the liquors have been found to vary from 2.72 to 4.4 and the constituent Cr have been found to be from zero to 8000 ppm from vegetable to chrome tanning industrial effluents studied. The stages involved in tanning and treatment of the effluent water waste including chemical treatment of Cr has been described with a special reference to supported liquid membranes process for removal of chromium ions. (author)

  7. Experiment of decontamination of radioactive liquid by a biological method; Experience de decontamination de liquides radioactifs far voie biologique

    Energy Technology Data Exchange (ETDEWEB)

    Wormser, G.

    1962-07-01

    The author reports experiments of treatment of radioactive liquid effluents by percolation on a bacterial bed like the one used for the treatment of sewer wastewaters. He also reports results obtained in other countries in terms of reduction of effluent radioactivity for various radioactive ions. The installation is described and results are presented in terms of variation of contamination of an effluent with respect to its recycling on a bacterial bed [French] Dans le monde entier, on se preoccupe des moyens de decontamination pour des liquides radioactifs. Les experiences de l'auteur ont confirme qu'un lit bacterien neuf peut donner de bons resultats: il est a noter que ce procede biologique se montre selectif a l'egard des divers ions radioactifs. (auteur)

  8. 40 CFR 417.82 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SOAP AND DETERGENT MANUFACTURING POINT SOURCE CATEGORY Manufacture of Liquid Soaps Subcategory § 417.82 Effluent limitations guidelines representing the...

  9. Design, calculation and testing on mock-up of B(U) f type LR 56 packaging for radioactive liquid effluent transport

    International Nuclear Information System (INIS)

    Belaud; Leconnetable; Daspet; Tombini; Tanguy

    1986-06-01

    Transport of radioactive acid liquid effluents are effected on tank truck inside nuclear center of the CEA. The cylindrical packaging type B(U) f has a capacity of 4,000l, a maximum permissible activity of 110 T Bq (3x10 4 Ci) and comprises a central element for liquid effluent containment to prevent contamination of environment and peripheral elements for mechanical, biological and thermal protection. This packaging is fixed on a trailer associated with a control box. Design and equipment of the packaging are studied for a maximum safety and in accordance with regulations [fr

  10. Technologies for the treatment of effluents from uranium mines, mills and tailings. Proceedings of a technical committee meeting

    International Nuclear Information System (INIS)

    2002-06-01

    Effluent treatment is an important aspect of uranium mining and milling operations that continues through decommissioning and site rehabilitation. During the life of a mine, effluent treatment is an integral part of the operation with all effluent either being recycled to the mill or processed through a water treatment plant before being released into the environment. During decommissioning and rehabilitation, effluent treatment must continue either through a water treatment plant of by using passive treatment techniques. Because of the recent closing of several uranium mines or mining districts, particularly in eastern Europe, effluent treatment is becoming an ever increasing concern. Therefore the IAEA convened a technical committee meeting (TCM) so that experts from different countries could discuss information and knowledge on effluent treatment processes and methods. The papers presented at the meeting describe techniques for treatment of effluents from uranium production operations - both past and present. This publication contains ten papers presented at the meeting; each of the papers was indexed separately

  11. 40 CFR 417.83 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SOAP AND DETERGENT MANUFACTURING POINT SOURCE CATEGORY Manufacture of Liquid Soaps Subcategory § 417.83 Effluent limitations guidelines representing the degree of...

  12. Photo-Electrochemical Treatment of Reactive Dyes in Wastewater and Reuse of the Effluent: Method Optimization

    Science.gov (United States)

    Sala, Mireia; López-Grimau, Víctor; Gutiérrez-Bouzán, Carmen

    2014-01-01

    In this work, the efficiency of a photo-electrochemical method to remove color in textile dyeing effluents is discussed. The decolorization of a synthetic effluent containing a bi-functional reactive dye was carried out by applying an electrochemical treatment at different intensities (2 A, 5 A and 10 A), followed by ultraviolet irradiation. The combination of both treatments was optimized. The final percentage of effluent decolorization, the reduction of halogenated organic volatile compound and the total organic carbon removal were the determinant factors in the selection of the best treatment conditions. The optimized method was applied to the treatment of nine simulated dyeing effluents prepared with different reactive dyes in order to compare the behavior of mono, bi, and tri-reactive dyes. Finally, the nine treated effluents were reused in new dyeing processes and the color differences (DECMC (2:1)) with respect to a reference were evaluated. The influence of the effluent organic matter removal on the color differences was also studied. The reuse of the treated effluents provides satisfactory dyeing results, and an important reduction in water consumption and salt discharge is achieved. PMID:28788251

  13. Short communication: Industrial effluent treatments using heavy ...

    African Journals Online (AJOL)

    Bioflocculants produced by Herbaspirillium sp. CH7, Paenibacillus sp. CH11, Bacillus sp. CH15 and a Halomonas sp. were preliminarily evaluated as flocculating agents in the treatment of industrial wastewater effluents. Industrial (1 local chemical-industry and 2 textile-industry: Biavin 109-medium blue dye and Whale dye) ...

  14. Anaerobic Treatment of Cane Sugar Effluent from Muhoroni Sugar ...

    African Journals Online (AJOL)

    It was therefore concluded that anaerobic treatment, particularly with pH control and seeding shows potential in first stage management of sugar mill wastewater. Keywords: cane sugar mill effluent, anaerobic treatment, batch reactor, waste stabilization ponds. Journal of Civil Engineering Research and Practice Vol.

  15. Pollution control in pulp and paper industrial effluents using integrated chemical-biological treatment sequences.

    Science.gov (United States)

    El-Bestawy, Ebtesam; El-Sokkary, Ibrahim; Hussein, Hany; Keela, Alaa Farouk Abu

    2008-11-01

    The main objective of the present study was to improve the quality of pulp and paper industrial wastewater of two local mills RAKTA and El-Ahlia, Alexandria, Egypt, and to bring their pollutant contents to safe discharge levels. Quality improvement was carried out using integrated chemical and biological treatment approaches after their optimization. Chemical treatment (alum, lime, and ferric chloride) was followed by oxidation using hydrogen peroxide and finally biological treatment using activated sludge (90 min for RAKTA and 60 min for El-Ahlia effluents). Chemical coagulation produced low-quality effluents, while pH adjustment during coagulation treatment did not enhance the quality of the effluents. Maximum removal of the tested pollutants was achieved using the integrated treatment and the pollutants recorded residual concentrations (RCs) of 34.67, 17.33, 0.13, and 0.43 mg/l and 15.0, 11.0, 0.0, and 0.13 mg/l for chemical oxygen demand (COD), biochemical oxygen demand (BOD5), tannin and lignin, and silica in RAKTA and El-Ahlia effluents, respectively, all of which were below their maximum permissible limits (MPLs) for the safe discharge into water courses. Specific oxygen uptake rate (SOUR) and sludge volume index (SVI) values reflect good conditions and healthy activated sludge. Based on the previous results, optimized conditions were applied as bench scale on the raw effluents of RAKTA and El-Ahlia via the batch chemical and the biological treatment sequences proposed. For RAKTA effluents, the sequence was as follows: (1) coagulation with 375 mg/l FeCl3, (2) oxidation with 50 mg/l hydrogen peroxide, and (3) biological treatment using activated sludge with 2,000 mg/l initial concentration and 90 min hydraulic retention time (HRT), while for El-Ahlia raw effluents, the sequence was (1) coagulation with 250 mg/l FeCl3, (2) oxidation with 45 mg/l hydrogen peroxide, and (3) biological treatment using activated sludge with 2,000 mg/l initial concentration and 60

  16. Dry washing: the solution for contaminated liquid effluent releases

    International Nuclear Information System (INIS)

    L'homme, D.; Trambouze, P.

    1998-01-01

    The release of wash water used for contaminated garments poses an ever-increasing problem on nuclear sites. Even though the radioactivity is low, it mixes with organic compounds, thus polluting a large quantity of liquid effluents. In many cases, several thousands of m 3 /year per nuclear site are produced, which at times represents more than 30% of the volume of total releases. The conventional dry cleaning process is not a viable option, given that repeated washing cause clothes to fade and the odors are rot removed completely. In order to eliminate releases, STMI has developed, after several years of research with the Technological University of Compiegne, France, a solvent dry washing process for garments used in the nuclear industry. (author)

  17. SECONDARY WASTE/ETF (EFFLUENT TREATMENT FACILITY) PRELIMINARY PRE-CONCEPTUAL ENGINEERING STUDY

    International Nuclear Information System (INIS)

    May, T.H.; Gehner, P.D.; Stegen, Gary; Hymas, Jay; Pajunen, A.L.; Sexton, Rich; Ramsey, Amy

    2009-01-01

    This pre-conceptual engineering study is intended to assist in supporting the critical decision (CD) 0 milestone by providing a basis for the justification of mission need (JMN) for the handling and disposal of liquid effluents. The ETF baseline strategy, to accommodate (WTP) requirements, calls for a solidification treatment unit (STU) to be added to the ETF to provide the needed additional processing capability. This STU is to process the ETF evaporator concentrate into a cement-based waste form. The cementitious waste will be cast into blocks for curing, storage, and disposal. Tis pre-conceptual engineering study explores this baseline strategy, in addition to other potential alternatives, for meeting the ETF future mission needs. Within each reviewed case study, a technical and facility description is outlined, along with a preliminary cost analysis and the associated risks and benefits.

  18. A system for destroying mixed and hazardous wastes with no gas or liquid effluents

    International Nuclear Information System (INIS)

    Camp, D.W.; Upadhye, R.S.

    1992-04-01

    We developed a conceptual design for a processing system in which the organic components of hazardous or mixed waste would be destroyed, while discharging virtually no gaseous or liquid effluents. Only solid products would be produced. For mixed waste feeds these could then be transported and disposed as low level waste. This system would oxidize the organics using any one of several destruction processes adapted to replace air with a mixture of O 2 and recycled CO 2 . Net production Of CO 2 , HC1, and H 2 O in the dosed recycle system would be scrubbed or reacted to solid products such as CaCO 3 , NaCl, and concrete. This no-effluent design may improve community acceptance of a waste destruction system

  19. A review on effluent generation in coal mines and its treatment methods

    Energy Technology Data Exchange (ETDEWEB)

    Sethi, R.; Karmakar, N.C.; Gupta, S. [Banaras Hindu University, Varanasi (India)

    2008-07-01

    The waste water of coal washeries, coal handling plants, workshops and overburden runoff of a coal mine contains a high concentration of suspended fine particles which usually remain after treatment in sedimentation tanks. The study on the performance characteristics of different coagulants shows that the turbidity removal efficiency depends much on the characteristics of the effluent and combined coagulants perform better than individuals. The various sources of generation of effluent and their treatment methods are discussed. It is suggested that the mine owners should consider the mine effluent as a rich source of both fine particles of coal and precious water. The coal particles are of high grade and may be used in coke preparation and water may be reused in mine to avoid the extra cost for water. The effluent treatment methods are required to be studied properly, so that less consumption of chemicals will be possible. If polyelectrolyte is used along with the other coagulants, the clarification performance will be improved. The best combination of chemicals are selected and practiced in mines. 14 refs., 5 tabs.

  20. Study on color removal of Sewage Treatment Plant (STP effluent using granular activated carbon

    Directory of Open Access Journals (Sweden)

    Nurfida Anita

    2018-01-01

    Full Text Available Recycling of sewage treatment plant (STP effluent is one of the attractive solutions to fulfill clean water for hotels and malls in Indonesia. STP effluent has average characteristics as follow: pH 6.8; color (true color 107 PtCo; A254 (UV absorption 0.36 cm-1 and COD 35.9 mg/L. Because of high color and organics contents, STP effluent needs further treatment such as activated carbon adsorption. Batch and continuous treatment of synthetic STP effluent by a commercial granular activated carbon (Filtrasorb 300 were investigated. The results show that adsorption capacity of the Filtrasorb 300 for color body of STP effluent was 184 PCU/g of carbon. Langmuir model is appropriate to describe the isotherm adsorption process in this study, with Qm: 476.2 PCU/g of carbon. The results of isotherm adsorption model evaluation, SEM photograph and FTIR analysis show that color adsorption occurred was physical adsoption.

  1. Hazard Baseline Downgrade Effluent Treatment Facility

    International Nuclear Information System (INIS)

    Blanchard, A.

    1998-01-01

    This Hazard Baseline Downgrade reviews the Effluent Treatment Facility, in accordance with Department of Energy Order 5480.23, WSRC11Q Facility Safety Document Manual, DOE-STD-1027-92, and DOE-EM-STD-5502-94. It provides a baseline grouping based on the chemical and radiological hazards associated with the facility. The Determination of the baseline grouping for ETF will aid in establishing the appropriate set of standards for the facility

  2. Removal of novel antiandrogens identified in biological effluents of domestic wastewater by activated carbon.

    Science.gov (United States)

    Ma, Dehua; Chen, Lujun; Liu, Rui

    2017-10-01

    Environmental antiandrogenic (AA) contaminants in effluents from wastewater treatment plants have the potential for negative impacts on wildlife and human health. The aim of our study was to identify chemical contaminants with likely AA activity in the biological effluents and evaluate the removal of these antiandrogens (AAs) during advanced treatment comprising adsorption onto granular activated carbon (GAC). In this study, profiling of AA contaminants in biological effluents and tertiary effluents was conducted using effect-directed analysis (EDA) including high performance liquid chromatography (HPLC) fractionation, a recombinant yeast screen containing androgen receptor (YAS), in combination with mass spectrometry analyses. Analysis of a wastewater secondary effluent from a membrane bioreactor revealed complex profiles of AA activity comprising 14 HPLC fractions and simpler profiles of GAC effluents with only 2 to 4 moderately polar HPLC fractions depending on GAC treatment conditions. Gas chromatography-mass spectrometry and ultra-high performance liquid chromatography-nanospray mass spectrometry analyses of AA fractions in the secondary effluent resulted in detection of over 10 chemical contaminants, which showed inhibition of YAS activity and were potential AAs. The putative AAs included biocides, food additives, flame retardants, pharmaceuticals and industrial contaminants. To our knowledge, it is the first time that the AA properties of N-ethyl-2-isopropyl-5-methylcyclohexanecarboxamide (WS3), cetirizine, and oxcarbazepine are reported. The EDA used in this study was proven to be a powerful tool to identify novel chemical structures with AA activity in the complex aquatic environment. The adsorption process to GAC of all the identified antiandrogens, except WS3 and triclosan, fit well with the pseudo-second order kinetics models. Adsorption to GAC could further remove most of the AAs identified in the biological effluents with high efficiencies. Copyright

  3. Order of 24 July 1992 on the licensing of liquid radioactive effluent releases from the large nuclear installation called Atalante at the nuclear research centre in the Rhone valley on the Marcoule nuclear site

    International Nuclear Information System (INIS)

    1992-01-01

    This Order fixes the annual authorized limits and procedures for the transfer from Atalante to the Cogema establishment also at Marcoule of the low-level liquid effluents for treatment. It also specifies the measures for their control and surveillance. (NEA)

  4. Decree No 74-1181 of 31 December 1974 concerning liquid radioactive effluent releases from nuclear installations

    International Nuclear Information System (INIS)

    1975-01-01

    This Decree prescribes the licensing procedure for the release of liquid wastes from nuclear installations as well as the technical supervision of such operations. It does not apply to the transport of radioactive effluents which is governed by the regulations on the transport of dangerous goods. (NEA) [fr

  5. Occurrence of disinfection byproducts in United States wastewater treatment plant effluents

    KAUST Repository

    Krasner, Stuart W.; Westerhoff, Paul K.; Chen, Baiyang; Rittmann, Bruce E.; Amy, Gary L.

    2009-01-01

    Effluents from wastewater treatment plants (WWTPs) contain disinfection byproducts (DBPs) of health concern when the water is utilized downstream as a potable water supply. The pattern of DBP formation was strongly affected by whether or not the WWTP achieved good nitrification. Chlorine addition to poorly nitrified effluents formed low levels of halogenated DBPs, except for (in some cases) dihalogenated acetic acids, but often substantial amounts of N-nitrosodimethyamine (NDMA). Chlorination of well-nitrified effluent typically resulted in substantial formation of halogenated DBPs but much less NDMA. For example, on a median basis after chlorine addition, the well-nitrified effluents had 57 μg/L of trihalomethanes [THMs] and 3 ng/L of NDMA, while the poorly nitrified effluents had 2 μg/L of THMs and 11 ng/L of NDMA. DBPs with amino acid precursors (haloacetonitriles, haloacetaldehydes) formed at substantial levels after chlorination of well-nitrified effluent. The formation of halogenated DBPs but not that of NDMA correlated with the formation of THMs in WWTP effluents disinfected with free chlorine. However, THM formation did not correlate with the formation of other DBPs in effluents disinfected with chloramines. Because of the relatively high levels of bromide in treated wastewater, bromine incorporation was observed in various classes of DBPs. © 2009 American Chemical Society.

  6. Occurrence of disinfection byproducts in United States wastewater treatment plant effluents

    KAUST Repository

    Krasner, Stuart W.

    2009-11-01

    Effluents from wastewater treatment plants (WWTPs) contain disinfection byproducts (DBPs) of health concern when the water is utilized downstream as a potable water supply. The pattern of DBP formation was strongly affected by whether or not the WWTP achieved good nitrification. Chlorine addition to poorly nitrified effluents formed low levels of halogenated DBPs, except for (in some cases) dihalogenated acetic acids, but often substantial amounts of N-nitrosodimethyamine (NDMA). Chlorination of well-nitrified effluent typically resulted in substantial formation of halogenated DBPs but much less NDMA. For example, on a median basis after chlorine addition, the well-nitrified effluents had 57 μg/L of trihalomethanes [THMs] and 3 ng/L of NDMA, while the poorly nitrified effluents had 2 μg/L of THMs and 11 ng/L of NDMA. DBPs with amino acid precursors (haloacetonitriles, haloacetaldehydes) formed at substantial levels after chlorination of well-nitrified effluent. The formation of halogenated DBPs but not that of NDMA correlated with the formation of THMs in WWTP effluents disinfected with free chlorine. However, THM formation did not correlate with the formation of other DBPs in effluents disinfected with chloramines. Because of the relatively high levels of bromide in treated wastewater, bromine incorporation was observed in various classes of DBPs. © 2009 American Chemical Society.

  7. Filtration device for active effluents

    International Nuclear Information System (INIS)

    Guerin, M.; Meunier, G.

    1994-01-01

    Among the various techniques relating to solid/liquid separations, filtration is currently utilized for treating radioactive effluents. After testing different equipments on various simulated effluents, the Valduc Center has decided to substitute a monoplate filter for a rotative diatomite precoated filter

  8. Soil plutonium and cesium in stream channels and banks of Los Alamos liquid effluent-receiving areas

    International Nuclear Information System (INIS)

    Nyhan, J.W.; White, G.C.; Trujillo, G.

    1982-01-01

    Stream channel sediments and adjacent bank soils found in three intermittent streams used for treated liquid effluent disposal at Los Alamos, New Mexico were sampled to determine the distribution of 238 Pu, sup(239,240)Pu and 137 Cs. Radionuclide concentrations and inventories were determined as functions of distance downstream from the waste outfall and from the center of the stream channel, soil sampling depth, stream channel-bank physiography, and the waste use history of each disposal area. Radionuclide concentrations in channel sediments were inversely related to distances up to 10 km downstream from the outfalls. For sites receiving appreciable waste effluent additions, contaminant concentrations in bank soils decreased with perpendicular distances greater than 0.38 m from the stream channel, and with stream bank sampling depths greater than 20-40 cm. Concentrations and total inventories of radionuclides in stream bank soils generally decreased as stream bank height increased. Inventory estimates of radionuclides in channel sediments exhibited coefficients of variation that ranged 0.41-2.6, reflecting the large variation in radionuclide concentrations at each site. Several interesting temporal relationships of these radionuclides in intermittent streams were gleaned from the varying waste use histories of the three effluent-receiving areas. Eleven years after liquid wastes were added to one canyon, the major radionuclide inventories were found in the stream bank soils, unlike most of the other currently-used receiving areas. A period of time greater than 6 yr seems to be required before the plutonium in liquid wastes currently added to the canyon is approximately equilibrated with the plutonium in the bank soils. These observations are discussed relative to waste management practices in these southwestern intermittent streams. (author)

  9. Soil plutonium and cesium in stream channels and banks of Los Alamos liquid effluent-receiving areas.

    Science.gov (United States)

    Nyhan, J W; White, G C; Trujillo, G

    1982-10-01

    Stream channel sediments and adjacent bank soils found in three intermittent streams used for treated liquid effluent disposal at Los Alamos, New Mexico were sampled to determine the distribution of 238Pu, 239,240Pu and 137Cs. Radionuclide concentrations and inventories were determined as functions of distance downstream from the waste outfall and from the center of the stream channel, soil sampling depth, stream channel-bank physiography, and the waste use history of each disposal area. Radionuclide concentrations in channel sediments were inversely related to distances up to 10 km downstream from the outfalls. For sites receiving appreciable waste effluent additions, contaminant concentrations in bank soils decreased with perpendicular distances greater than 0.38 m from the stream channel, and with stream bank sampling depths greater than 20-40 cm. Concentrations and total inventories of radionuclides in stream bank soils generally decreased as stream bank height increased. Inventory estimates of radionuclides in channel sediments exhibited coefficients of variation that ranged 0.41-2.6, reflecting the large variation in radionuclide concentrations at each site. Several interesting temporal relationships of these radionuclides in intermittent streams were gleaned from the varying waste use histories of the three effluent-receiving areas. Eleven yr after liquid wastes were added to one canyon, the major radionuclide inventories were found in the stream bank soils, unlike most of the other currently-used receiving areas. A period of time greater than 6 yr seems to be required before the plutonium in liquid wastes currently added to the canyon is approximately equilibrated with the plutonium in the bank soils. These observations are discussed relative to waste management practices in these southwestern intermittent streams.

  10. Experiment of decontamination of radioactive liquid by a biological method

    International Nuclear Information System (INIS)

    Wormser, G.

    1962-01-01

    The author reports experiments of treatment of radioactive liquid effluents by percolation on a bacterial bed like the one used for the treatment of sewer wastewaters. He also reports results obtained in other countries in terms of reduction of effluent radioactivity for various radioactive ions. The installation is described and results are presented in terms of variation of contamination of an effluent with respect to its recycling on a bacterial bed [fr

  11. Utilization of ultraviolet radiation in effluent disinfestation of domestic waste treatment systems

    International Nuclear Information System (INIS)

    Camacho, P.R.R.; Andrade e Silva, L.G. de

    1995-01-01

    Ultraviolet radiation disinfection of Upflow Anaerobic Sludge Biodigestor (UASB) and UASB with aerated lagoon pos-treatment effluents is possible to be reached utilizing a single low pressure mercury lamp arc (15 W nominal power) in a shell tube flow through reactor (1.2 L useful volume). Fecal coliforms, total coliforms and colifages were used as microbiological parameters. For fecal coliforms, about 3 logarithmic units (log. un.) was removed from UASB with aerated lagoon pos-treatment effluent and 4 log. un. from UASB effluent with 7 and 30 seconds of hydraulic retention time, respectively. Good empirical correlations were obtained between microbiological parameters and hydraulic retention times. (author). 4 refs, 1 fig, 3 tabs

  12. Applicability and costs of nanofiltration in combination with photocatalysis for the treatment of dye house effluents

    Directory of Open Access Journals (Sweden)

    Wolfgang M. Samhaber

    2014-04-01

    Full Text Available Nanofiltration (NF is a capable method for the separation of dyes, which can support and even improve the applicability of photocatalysis in effluent-treatment processes. The membrane process usually will need a special pre-treatment to avoid precipitation and fouling on the membrane surface. Conceptually NF can be applied in the pre-treatment prior to the catalytic reactor or in connection with the reactor to separate the liquid phase from the reaction system and to recycle finely suspended catalysts and/or organic compounds. When concerning such reaction systems on a bigger scale, cost figures will prove the usefulness of those concepts. Different applications of photocatalysis on the lab-scale have been published in recent years. Membrane technology is used almost in all those processes and an overview will be given of those recently published systems that have been reported to be potentially useful for a further scale-up. NF membranes are mostly used for the more sophisticated separation step of these processes and the additional costs of the NF treatment, without any associated equipments, will be described and illustrated. The total specific costs of industrial NF treatment processes in usefully adjusted and designed plants range from 1 to 6 US$/m3 treated effluent. Combination concepts will have a good precondition for further development and upscaling, if the NF costs discussed here in detail will be, together with the costs of photocatalysis, economically acceptable.

  13. Design and implementation of an intensified coprecipitation reactor for the treatment of liquid radioactive wastes

    International Nuclear Information System (INIS)

    Flouret, Julie; Barre, Yves; Muhr, Herve; Plasari, Edouard

    2013-01-01

    The coprecipitation is a robust and inexpensive process for the treatment of important volumes of low and intermediate radioactive level liquid wastes. Its major inconvenient is the huge volume of sludge generated. The purpose of this work is to optimize the industrial coprecipitation continuous process by achieving the following objectives: - maximize the decontamination efficiency; - minimize the volume of sludge generated by the process; - reduce the treatment cost decreasing the installation volume. An innovative reactor with an infinite recycling ratio was therefore designed. It is a multifunctional reactor composed of two zones: a perfectly mixed precipitation zone and a classifier to perform liquid-solid separation. The experiments are focused on the coprecipitation of strontium by barium sulphate. The effluent containing sulphate ions and the barium nitrate solution are injected in the reaction zone where strontium and barium co-precipitate as sulphates. The produced solid phase is returned into the reaction zone by the classifier and goes out slowly from the reactor bottom with a residence time much higher than the liquid phase. This creates both a high concentration of solid phase in the reaction zone and a high efficiency of decontamination. The experimental conditions simulate the industrial effluents. The total treatment flow rate is 17 L/h, with an effluent flow rate of 16 L/h and a reactive flow rate of 1 L/h, hence a mean residence time of 10 minutes. In these experimental conditions, the molar ratio sulphate/barium after mixing corresponds to 4.9. These conditions are used in the reprocessing plant of La Hague. The decontamination factor reached in these experimental conditions is excellent: DF = 1500. The decontamination factor obtained with the classical continuous process is only equal to 60. Different process parameters are studied in order to optimize the reactor/classifier: residence time, barium nitrate flow rate and racking flow rate. The

  14. 200 area effluent treatment facility opertaional test report

    International Nuclear Information System (INIS)

    Crane, A.F.

    1995-01-01

    This document reports the results of the 200 Area Effluent Treatment Facility (200 Area ETF) operational testing activities. These Operational testing activities demonstrated that the functional, operational and design requirements of the 200 Area ETF have been met and identified open items which require retesting

  15. Methods of reducing liquid effluent from the OSU TRIGA MKII Reactor

    International Nuclear Information System (INIS)

    Higginbotham, J.F.; Dodd, B.; Pratt, D.S.; Smith, S.; Anderson, T.V.

    1992-01-01

    In 1991, the OSU Radiation Center implemented a program to minimize the liquid effluent generated by the reactor facility. The goal of program is to become a 'zero' release facility with regards to routine liquid discharges. Only two liquid waste streams exist for the OSU reactor facility: discharges resulting from changing resin in the deminerializer and decontamination of equipment, primarily sample loading tubes. This paper describes a system which allows remote resin exchange to performed with the collection of all flush water. This water is then recycled for use as makeup for the primary water system. The service life of the resin is maximized by using a steam distillation unit as the source of makeup water to the deminerializer system instead of water coming directly from the City of Corvallis water supply. The second source of liquid waste water comes from the decontamination of the plastic loading tubes used to encapsulate samples. This process originally involved placing the tubes in a dishwasher and sending the discharge to a hold up tank. If the radionuclide concentrations in the tank were below the maximum permissible concentrations of 10CFR20 then it was released to the sanitary sewerage. This process was replaced in 1991 with a system which involved manual washing and rinsing of the tubes with the liquids being absorbed for disposal as solid waste. This paper will also describe the system which is being built to replace this process. It will use the dishwasher unit again but the liquid discharge will collected for absorption and disposal as solid waste. (author)

  16. Post-treatment of anaerobic reactor effluent using coagulation/oxidation followed by double filtration.

    Science.gov (United States)

    Cavallini, Grasiele Soares; de Sousa Vidal, Carlos Magno; de Souza, Jeanette Beber; de Campos, Sandro Xavier

    2016-04-01

    This study evaluates the efficacy of a sanitary sewage treatment system, proposing post-treatment of the effluent generated by the upflow anaerobic sludge blanket UASB reactor, through a Fenton coagulation/oxidation ((ferric chloride (FC) or ferrous sulfate (FS) and peracetic acid (PAA)), followed by a double filtration system, composed of a gravel ascending drainage filter and a sand descending filter. Following the assessment of treatability, the system efficiency was evaluated using physicochemical and microbiological parameters. In all treatments performed in the pilot unit, total suspended solids (TSS) were completely removed, leading to a decrease in turbidity greater than 90% and close to 100% removal of total phosphorous. In the FC and PAA combination, the effluent was oxygenated prior to filtration, enabling a more significant removal of biochemical oxygen demand (BOD), which characterizes aerobic degradation even in a quick sand filter. The treatments carried out in the presence of the PAA oxidizing agent showed a more significant bleaching of the effluent. Concerning the microbiological parameters, the simultaneous use of PAA and FC contributed to the partial inactivation of the assessed microorganisms. A 65% recovery of the effluent was obtained with the proposed treatment system, considering the volume employed in filter backwashing.

  17. Effects of advanced treatments of wastewater effluents on estrogenic and reproductive health impacts in fish.

    Science.gov (United States)

    Filby, Amy L; Shears, Janice A; Drage, Briane E; Churchley, John H; Tyler, Charles R

    2010-06-01

    Whether the implementation of additional treatments for the removal of estrogens from wastewater treatment works (WwTWs) effluents will eliminate their feminizing effects in exposed wildlife has yet to be established, and this information is crucial for future decisions on investment into WwTWs. Here, granular activated carbon (GAC), ozone (O(3)), and chlorine dioxide (ClO(2)) were investigated for their effectiveness in reducing steroidal estrogen levels in a WwTW effluent and assessments made on the associated estrogenic and reproductive responses in fathead minnows (Pimephales promelas) exposed for 21 days. All treatments reduced the estrogenicity of the standard-treated (STD) effluent, but with different efficacies; ranging between 70-100% for total estrogenicity and 53-100% for individual steroid estrogens. In fish exposed to the GAC- and ClO(2)- (but not O(3)-) treated effluents, there was no induction of plasma vitellogenin (VTG) or reduction in the weight of the fatpad, a secondary sex character in males, as occurred for fish exposed to STD effluent. This finding suggests likely benefits of employing these treatment processes for the reproductive health in wild fish populations living in rivers receiving WwTW discharges. Exposure of pair-breeding minnows to the GAC-treated effluent, however, resulted in a similar inhibition of egg production to that occurring for exposure to the STD effluent (34-40%). These data, together with a lack of effect on egg production of the estrogen, ethinylestradiol (10 ng/L), alone, suggest that chemical/physical properties of the effluents rather than their estrogenicity were responsible for the reproductive effect and that these factor(s) were not remediated for through GAC treatment. Collectively, our findings illustrate the importance of assessing integrative biological responses, rather than biomarkers alone, in the assessment and improvement of WwTW technologies for the protection of wild fish populations.

  18. Wastewater treatment plant effluent introduces recoverable shifts in microbial community composition in urban streams

    Science.gov (United States)

    Ledford, S. H.; Price, J. R.; Ryan, M. O.; Toran, L.; Sales, C. M.

    2017-12-01

    New technologies are allowing for intense scrutiny of the impact of land use on microbial communities in stream networks. We used a combination of analytical chemistry, real-time polymerase chain reaction (qPCR) and targeted amplicon sequencing for a preliminary study on the impact of wastewater treatment plant effluent discharge on urban streams. Samples were collected on two dates above and below treatment plants on the Wissahickon Creek, and its tributary, Sandy Run, in Montgomery County, PA, USA. As expected, effluent was observed to be a significant source of nutrients and human and non-specific fecal associated taxa. There was an observed increase in the alpha diversity at locations immediately below effluent outflows, which contributed many taxa involved in wastewater treatment processes and nutrient cycling to the stream's microbial community. Unexpectedly, modeling of microbial community shifts along the stream was not controlled by concentrations of measured nutrients. Furthermore, partial recovery, in the form of decreasing abundances of bacteria and nutrients associated with wastewater treatment plant processes, nutrient cycling bacteria, and taxa associated with fecal and sewage sources, was observed between effluent sources. Antecedent moisture conditions impacted overall microbial community diversity, with higher diversity occurring after rainfall. These findings hint at resilience in stream microbial communities to recover from wastewater treatment plant effluent and are vital to understanding the impacts of urbanization on microbial stream communities.

  19. Post-treatment and reuse of secondary effluents using natural ltreatment systems: the Indian practices.

    Science.gov (United States)

    Kumar, D; Asolekar, S R; Sharma, S K

    2015-10-01

    Paper summarizes the results of India-wide survey of natural treatment systems (NTSs) for wastewater treatment and reuse. The quality of treated wastewater from different types of NTSs was analyzed for various physico-chemical and bacteriological parameters, and needs for post-treatment were identified. Currently, about 1838 million liters per day (MLD) of wastewater is being treated using NTSs, of which the contributions of polishing ponds, waste stabilization ponds, duckweed ponds, constructed wetlands, and Karnal technology were found to be 53.39, 45.15, 0.13, 0.55, and 0.78%, respectively. Among the NTSs studied, constructed wetland was found most efficient in removal of pollutants including nitrogen, phosphorus, total coliform, and fecal coliform in the range of 76, 61, 99.956, and 99.923%, respectively. Of all types of NTSs, only constructed wetland was found to meet the total coliform count requirements (effluents for irrigation; effluents from 48 systems are being discharged into river or lake, and remaining 38 systems have not found any designated use of treated effluent. The chlorination was the only post-treatment, which is being practiced at only three wastewater treatment facilities. During post-treatment, 1-2 ppm of chlorine is applied to the secondary effluent irrespective of its quality. The treated effluents from different NTSs contain fecal bacteria in the magnitude of 10(3) to 10(5), which may cause the severe health impacts through contamination of groundwater as well as surface water resources.

  20. Behavior of natural radionuclides in wastewater treatment plants

    International Nuclear Information System (INIS)

    Camacho, A.; Montaña, M.; Vallés, I.; Devesa, R.; Céspedes-Sánchez, R.; Serrano, I.; Blázquez, S.; Barjola, V.

    2012-01-01

    56 samples, including influent, primary effluent, secondary effluent and final effluent wastewater from two Spanish municipal wastewater treatment plants (WWTPs), were analyzed to assess both the occurrence and behavior of natural radioactivity during 12 sampling campaigns carried out over the period 2007–2010. Influent and final effluent wastewaters were sampled by taking into account the hydraulic residence time within the WWTP. A wide range of gross alpha activities (15–129 mBq/L) and gross beta activities (477–983 mBq/L) in liquid samples were obtained. A correlation analysis between radioactivity in liquid samples and the performance characteristics of the WWTPs was performed. The results in liquid samples showed that gross beta activities were not influenced by treatment in the studied WWTPs. However, gross alpha activities behave differently and an increase was detected in the effluent values compared with influent wastewater. This behavior was due to the increase in the total dissolved uranium produced during secondary treatment. The results indicate that the radiological characteristics of the effluents do not present a significant radiological risk and make them suitable for future applications. - Highlights: ► Liquids from WWTPs were analyzed to know the behavior of natural radionuclides. ► Gross beta activities were not influenced by treatment in the studied WWTPs. ► Increase in gross alpha activity was observed due to uranium desorption/solubilisation. ► Correlation between gross alpha activity and the chemical oxygen demand was found

  1. Solutions to microplastic pollution - Removal of microplastics from wastewater effluent with advanced wastewater treatment technologies.

    Science.gov (United States)

    Talvitie, Julia; Mikola, Anna; Koistinen, Arto; Setälä, Outi

    2017-10-15

    Conventional wastewater treatment with primary and secondary treatment processes efficiently remove microplastics (MPs) from the wastewater. Despite the efficient removal, final effluents can act as entrance route of MPs, given the large volumes constantly discharged into the aquatic environments. This study investigated the removal of MPs from effluent in four different municipal wastewater treatment plants utilizing different advanced final-stage treatment technologies. The study included membrane bioreactor treating primary effluent and different tertiary treatment technologies (discfilter, rapid sand filtration and dissolved air flotation) treating secondary effluent. The MBR removed 99.9% of MPs during the treatment (from 6.9 to 0.005 MP L -1 ), rapid sand filter 97% (from 0.7 to 0.02 MP L -1 ), dissolved air flotation 95% (from 2.0 to 0.1 MP L -1 ) and discfilter 40-98.5% (from 0.5 - 2.0 to 0.03-0.3 MP L -1 ) of the MPs during the treatment. Our study shows that with advanced final-stage wastewater treatment technologies WWTPs can substantially reduce the MP pollution discharged from wastewater treatment plants into the aquatic environments. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Application of biotechnology for treatment of nitrogen compounds in gold mill effluents

    International Nuclear Information System (INIS)

    Kapoor, A.; Gould, W.D.; Bedard, P.; Morin, K.

    2004-01-01

    This paper presents the results of a research study that is being conducted by the Mine Effluents Program, Mining and Mineral Science Laboratory (MMSL), Natural Resources Canada aimed at evaluating biotechnology processes for the treatment of nitrogen compounds such as thiocyanide (CNS) and ammonia (NH 4- N) which are present in gold mill effluents. A sequencing batch reactor (SBR) technology, commonly used for the biological treatment of municipal and industrial effluents, was used in this study. In the SBR process, the micro-organisms were able to degrade CNS to NH 4- N and NH 4- N to nitrate (NO 3- N) at operating conditions of two 12 h treatment cycles per day, with pH maintained in the 7.4 to 7.6 range, and at room temperature (approximately 21 o C) and also at 12 o C. The end products of CNS and NH 4- N biological oxidation were NO 3- N and sulphate (SO 4 ) that are relatively non-toxic. Partial removal of NO 3- N was achieved by biological denitrification reactions in the SBR process. The SBR process effluent was measured to be non-toxic to rainbow trout based on the 96 h acute toxicity test. The microbial consortium isolated from the SBR treating a simulated effluent was able to effectively oxidize CNS and NH 4- N to NO 3- N in water samples (under batch conditions) collected at three mine sites located in Quebec, the Northwest Territories, and Yukon. (author)

  3. The conceptual flowsheet of effluent treatment during preparing spherical fuel elements of HTR

    Energy Technology Data Exchange (ETDEWEB)

    Ying, Quan, E-mail: quanying@tsinghua.edu.cn; Xiao-tong, Chen; Bing, Liu; Gen-na, Fu; Yang, Wang; You-lin, Shao; Zhen-ming, Lu; Ya-ping, Tang; Chun-he, Tang

    2014-05-01

    High temperature gas-cooled reactor (HTR) is one of the advanced nuclear reactors owing to its inherent safety and broad applications. For HTR, one of the key components is the ceramic fuel element. During the preparation of spherical fuel elements, the radioactive effluent treatment is necessary. Referring to the current treatment technologies and methods, the conceptual flowsheet of low-level radioactive effluent treatment during preparing spherical fuel elements was established. According to the above treatment process, the uranium concentration was decreased from 200 mg/l to the level of discharged standard.

  4. Treatment of Industrial Liquid Waste of Steel Plating by Coagulation-Flocculation Using Sodium Biphosphate

    International Nuclear Information System (INIS)

    Subiarto; Herlan Martono

    2007-01-01

    Research about treatment of industrial liquid waste of steel plating by coagulation-flocculation using sodium biphosphate have been conducted. The purpose of the treatment was the content reduction of Cr, Ni, and Cu in the liquid waste, so that produced effluent with Cr, Ni, and Cu content until they laid under mutual standard. The variables studied in this process were the solution pH, the coagulant/waste volume comparison, the speed of the fast stirring, and the time of the fast stirring. Optimum separation efficiency on coagulation-flocculation process of liquid waste of steel plating using sodium biphosphate at the condition of solution ph 9, coagulant/waste volume comparation 1.50, the speed of the fast stirring 400 rpm, and the time of fast stirring is 5 minute. Low stirring was conducted at 60 rpm for 60 minute. The yields of optimum separation efficiency in this condition were 99.48 % for Cr, 99.51 % for Ni, and 99.03 % for Cu. (author)

  5. Global hepatic gene expression in rainbow trout exposed to sewage effluents: A comparison of different sewage treatment technologies

    Energy Technology Data Exchange (ETDEWEB)

    Cuklev, Filip, E-mail: filip.cuklev@neuro.gu.se [Institute of Neuroscience and Physiology, Department of Physiology, The Sahlgrenska Academy at the University of Gothenburg, Box 434, SE-405 30 Goeteborg (Sweden); Gunnarsson, Lina, E-mail: lina.gunnarsson@fysiologi.gu.se [Institute of Neuroscience and Physiology, Department of Physiology, The Sahlgrenska Academy at the University of Gothenburg, Box 434, SE-405 30 Goeteborg (Sweden); Cvijovic, Marija, E-mail: marija.cvijovic@chalmers.se [Institute of Neuroscience and Physiology, Department of Physiology, The Sahlgrenska Academy at the University of Gothenburg, Box 434, SE-405 30 Goeteborg (Sweden); Department of Mathematical Sciences, Chalmers University of Technology and University of Gothenburg, SE-412 96 Goeteborg (Sweden); Kristiansson, Erik, E-mail: erik.kristiansson@chalmers.se [Department of Mathematical Sciences, Chalmers University of Technology and University of Gothenburg, SE-412 96 Goeteborg (Sweden); Rutgersson, Carolin [Institute of Neuroscience and Physiology, Department of Physiology, The Sahlgrenska Academy at the University of Gothenburg, Box 434, SE-405 30 Goeteborg (Sweden); Bjoerlenius, Berndt, E-mail: berndtb@kth.se [Stockholm Water Company, Vaermdoevaegen 23, SE-131 55 Stockholm (Sweden); Larsson, D.G. Joakim, E-mail: joakim.larsson@fysiologi.gu.se [Institute of Neuroscience and Physiology, Department of Physiology, The Sahlgrenska Academy at the University of Gothenburg, Box 434, SE-405 30 Goeteborg (Sweden)

    2012-06-15

    Effluents from sewage treatment plants contain a mixture of micropollutants with the potential of harming aquatic organisms. Thus, addition of advanced treatment techniques to complement existing conventional methods has been proposed. Some of the advanced techniques could, however, potentially produce additional compounds affecting exposed organisms by unknown modes of action. In the present study the aim was to improve our understanding of how exposure to different sewage effluents affects fish. This was achieved by explorative microarray and quantitative PCR analyses of hepatic gene expression, as well as relative organ sizes of rainbow trout exposed to different sewage effluents (conventionally treated, granular activated carbon, ozonation (5 or 15 mg/L), 5 mg/L ozone plus a moving bed biofilm reactor, or UV-light treatment in combination with hydrogen peroxide). Exposure to the conventionally treated effluent caused a significant increase in liver and heart somatic indexes, an effect removed by all other treatments. Genes connected to xenobiotic metabolism, including cytochrome p450 1A, were differentially expressed in the fish exposed to the conventionally treated effluents, though only effluent treatment with granular activated carbon or ozone at 15 mg/L completely removed this response. The mRNA expression of heat shock protein 70 kDa was induced in all three groups exposed to ozone-treated effluents, suggesting some form of added stress in these fish. The induction of estrogen-responsive genes in the fish exposed to the conventionally treated effluent was effectively reduced by all investigated advanced treatment technologies, although the moving bed biofilm reactor was least efficient. Taken together, granular activated carbon showed the highest potential of reducing responses in fish induced by exposure to sewage effluents. - Highlights: Black-Right-Pointing-Pointer Livers of trout exposed to different sewage effluents were analysed by microarray. Black

  6. Global hepatic gene expression in rainbow trout exposed to sewage effluents: A comparison of different sewage treatment technologies

    International Nuclear Information System (INIS)

    Cuklev, Filip; Gunnarsson, Lina; Cvijovic, Marija; Kristiansson, Erik; Rutgersson, Carolin; Björlenius, Berndt; Larsson, D.G. Joakim

    2012-01-01

    Effluents from sewage treatment plants contain a mixture of micropollutants with the potential of harming aquatic organisms. Thus, addition of advanced treatment techniques to complement existing conventional methods has been proposed. Some of the advanced techniques could, however, potentially produce additional compounds affecting exposed organisms by unknown modes of action. In the present study the aim was to improve our understanding of how exposure to different sewage effluents affects fish. This was achieved by explorative microarray and quantitative PCR analyses of hepatic gene expression, as well as relative organ sizes of rainbow trout exposed to different sewage effluents (conventionally treated, granular activated carbon, ozonation (5 or 15 mg/L), 5 mg/L ozone plus a moving bed biofilm reactor, or UV-light treatment in combination with hydrogen peroxide). Exposure to the conventionally treated effluent caused a significant increase in liver and heart somatic indexes, an effect removed by all other treatments. Genes connected to xenobiotic metabolism, including cytochrome p450 1A, were differentially expressed in the fish exposed to the conventionally treated effluents, though only effluent treatment with granular activated carbon or ozone at 15 mg/L completely removed this response. The mRNA expression of heat shock protein 70 kDa was induced in all three groups exposed to ozone-treated effluents, suggesting some form of added stress in these fish. The induction of estrogen-responsive genes in the fish exposed to the conventionally treated effluent was effectively reduced by all investigated advanced treatment technologies, although the moving bed biofilm reactor was least efficient. Taken together, granular activated carbon showed the highest potential of reducing responses in fish induced by exposure to sewage effluents. - Highlights: ► Livers of trout exposed to different sewage effluents were analysed by microarray. ► Exposure to conventionally

  7. Treatment of low-level radioactive waste liquid by reverse osmosis

    International Nuclear Information System (INIS)

    Buckley, L.P.; Sen Gupta, S.K.; Slade, J.A.

    1995-01-01

    The processing of low-level radioactive waste (LLRW) liquids that result from operation of nuclear power plants with reverse osmosis systems is not common practice. A demonstration facility is operating at Chalk River Laboratories (of Atomic Energy of Canada Limited), processing much of the LLRW liquids generated at the site from a multitude of radioactive facilities, ranging from isotope production through decontamination operations and including chemical laboratory drains. The reverse osmosis system comprises two treatment steps--spiral wound reverse osmosis followed by tubular reverse osmosis--to achieve an average volume reduction factor of 30:1 and a removal efficiency in excess of 99% for most radioactive and chemical species. The separation allows the clean effluent to be discharged without further treatment. The concentrated waste stream of 3 wt% total solids is further processed to generate a solid product. The typical lifetimes of the membranes have been nearly 4000 hours, and replacement was required based on increased pressure drops and irreversible loss of permeate flux. Four years of operating experience with the reverse osmosis system, to demonstrate its practicality and to observe and record its efficiency, maintenance requirements and effectiveness, have proven it to be viable for volume reduction and concentration of LLRW liquids generated from nuclear-power-plant operations

  8. Assessment of derived emission limits for radioactive effluents resulted from the decommissioning activities of the VVR-S nuclear research reactor

    International Nuclear Information System (INIS)

    Tuca, C.; Stochioiu, A.; Sahagia, M.; Gurau, D.; Dragusin, M.

    2015-01-01

    This paper presents complex studies on establishment of derived emission limits for potential radionuclides emitted as gaseous and liquid effluents, during the decommissioning activities (2nd and 3rd phases) of a nuclear research reactor, cooled and moderated with distilled water, type VVR-S, owned by the IFIN-HH. In the present paper there are described: the analysis methods and equipment used, the methodologies for calculating doses and the Derived Emission Limits (DEL), the experimentally measured activities of the representative radionuclides found in gaseous and liquid effluents resulted from decommissioning activities, as well as the effective derived limits of liquid and gaseous effluents, applying the calculation methodologies, specific to critical categories of exposed subjects. A constraint effective dose limit for a person from the critical group of 50 μSv/year was considered in calculations. From the comparison of the two series of values, measured released activities and DELs, there has been concluded that for the gaseous effluents they comply with the DELs, while in the case of liquid effluents they are higher and consequently they must be treated as liquid radioactive wastes. - Highlights: • The DELs for gaseous and liquid effluents in decommissioning were studied. • The impact on the environment and critical group was assessed. • Gamma-ray spectrometry was used to determine the radionuclide composition. • Based on the dosimetry models, the values of conservative DELs were calculated. • The DELs are compliant for gases, not for liquids; require the treatment as rad-waste

  9. Nuclear liquid wastes treatment: study of the reverse osmosis membranes degradation under γ irradiation

    International Nuclear Information System (INIS)

    Combernoux, Nicolas

    2015-01-01

    The treatment of nuclear liquid wastes by reverse osmosis (RO) involved issues of the water radiolysis and the membrane ageing due to γ irradiation effects. Membrane performances (permeability, strontium and cesium retention) were assessed after γ irradiation. Irradiation was carried out with an external 60 Co source in different conditions that simulated real used of the process (dose from 0.1 to 1 MGy, dose rate of 0.5 and 5 kGy.h -1 , with or without oxygen or water). Several analytical methods were performed to evaluate irradiation effects (ATR-FTIR, XPS, gas production, water soluble species released from the membrane). The methodology developed led to relevant information due to an innovative analytical protocol. Membrane performances started dropping between 0.2 and 0.5 MGy with oxygen and water (dose rate 0.5 kGy.h -1 ). This shift was linked to chains scissions inside the membrane active layer. The membrane degradation was weaker without oxygen or water or at high dose rate (5 kGy.h -1 ). Results showed that each analysis comforted each other. Membrane performances were also evaluated with three different types of liquid effluents, representing radioactive effluents from a post-disaster situation (groundwater type), disaster situation (seawater) or process water. Experiments were carried out at lab and pilot scales. Results indicated that the treatment of each effluent was possible by RO with an adequate choice of membrane and operating parameters. Finally, the time to reach an integrated dose threshold for the membrane in real conditions was estimated with the RABBI software: a dozen of days in the case of disaster situation to several years in the two other cases. (author) [fr

  10. The use of magnetite for decontaminating alpha containing effluents

    International Nuclear Information System (INIS)

    Ivens, R.

    1988-06-01

    The feasibility of retention of precipitated magnetite by magnetic filtration followed by direct cementation offered an attractive alternative to conventional ferric hydroxide treatment of radioactive liquid effluents. The magnetically-assisted dewatering of laboratory-prepared magnetite was examined in a number of ways, none of which achieved the desired optimum solids content for cementation. Attempts to prepare magnetite in situ from typical effluents containing iron were unsuccessful owing to the presence of interfering ions. Preformed magnetite was reasonably effective at absorbing actinides from solution but did not appear to offer any significant advantage over ferric hydroxide. (author)

  11. Radioactive clearance discharge of effluent from nuclear and radiation facilities

    International Nuclear Information System (INIS)

    Liu Xinhua; Xu Chunyan

    2013-01-01

    On the basis of the basic concepts of radiation safety management system exemption, exclusion and clearance, we expound that the general industrial gaseous and liquid effluent discharges are exempted or excluded, gaseous and liquid effluent discharged from nuclear and radiation facilities are clearance, and non-radioactive. The main purpose of this paper is to clarify the concepts, reach a consensus that the gaseous and liquid effluent discharged from nuclear and radiation facilities are non-radioactive and have no hazard to human health and natural environment. (authors)

  12. Treatment of Alkaline Stripped Effluent in Aerated Constructed Wetlands: Feasibility Evaluation and Performance Enhancement

    Directory of Open Access Journals (Sweden)

    Keli He

    2016-09-01

    Full Text Available Ammonium stripping has gained increasing interest for nitrogen recovery in anaerobically digested effluents. However, the stripped effluents often still do not meet discharge standards, having high pH and residual pollutants. Constructed wetlands (CWs are an easy to operate ecosystem and have a long history of application in treatment of wastewaters with extreme pH, such as acid mine drainage. However, knowledge of the mechanistic details involved in the use of CWs to treat high alkaline drainage, such as stripped effluent, is insufficient. This study explored the feasibility and effectiveness of using three sub-surface horizontal flow CWs to treat high alkaline stripped effluent (pH > 10. Two intensification strategies—intermittent aeration and effluent recirculation—were evaluated to enhance nitrogen depuration performance. The results show that the treatment of alkaline stripped effluent is feasible due to the high buffering capacity of the wetlands. Effluent recirculation combined with intermittent artificial aeration improves nitrogen removal, with 71% total nitrogen (TN removal. Ammonia volatilization from the surface of the wetlands in high alkaline conditions only contributed to 3% of the total removed ammonium. The microbial abundance and activity had significant diversity for the various enhancement strategies used in the constructed wetland systems. Anammox is an important process for nitrogen removal in CWs treating alkaline stripped effluent, and possible enhancements of this process should be investigated further.

  13. Determination and behaviour of plutonium emitted with liquid effluents and exhaust air into the environment of the Nuclear Research Centre Karlsruhe

    International Nuclear Information System (INIS)

    Schuettelkopf, H.; Pimpl, M.

    1986-01-01

    The plutonium concentrations in the surroundings of the Karlsruhe Nuclear Research Centre (KfK) are in the range of variation of the global plutonium contamination caused by fallout of atmospheric nuclear tests. Exclusively in the sediments of the Old River Rhine, which serves as main canal for the liquid effluents, higher plutonium concentrations could be detected. The dose exposure of the population living in the environment of the KfK caused by the measured plutonium concentrations is negligible low. From the Karlsruhe Reprocessing Plant (WAK) and the facilities needed to decontaminate radioactive wastes 0.48 GBq (13 mCi) plutonium alpha activity has been emitted within 11 years of operation until 1982 - 1/3 with the liquid effluents and 2/3 with the exhaust air. Following the pathway with the exhaust air, plutonium concentrations in the environment of the Karlsruhe Reprocessing Plant were measured in groundlevel air, in soil, in plants, in food and in animal tissues. Radioecological parameters like dispersion factors, deposition velocities, migration velocities in soil and transfer soil-to-plant were investigated. Following the pathway with the liquid effluents, plutonium concentrations were measured in surface waters, sediments, water plants, plankton and animals. Dilution and sedimentation behaviour were studied as well as the transfer water-to-plant and water-to-animals. (orig.) [de

  14. Analysis of copper losses throughout weak acid effluent flows generated during off-gas treatment in the New Copper Smelter RTB Bor

    Directory of Open Access Journals (Sweden)

    Dragana Ivšić-Bajčeta

    2013-09-01

    Full Text Available The previous inadequate treatment of off-gas in RTB Bor in Serbia has resulted in serious pollution of the environment and the possibly high losses of copper through the effluent flows. The project of New Copper Smelter RTB Bor, besides the new flash smelting furnace (FSF and the reconstruction of Pierce-Smith converter (PSC, includes more effective effluent treatment. Paper presents an analysis of the new FSF and PSC off-gas treatment, determination of copper losses throughout generated wastewaters and discussion of its possible valorization. Assumptions about the solubility of metals phases present in the FSF and PSC off-gas, obtained by the treatment process simulation, were compared with the leaching results of flue dusts. Determined wastewaters characteristics indicate that the PSC flow is significantly richer in copper, mostly present in insoluble metallic/sulfide form, while the FSF flow has low concentration of copper in the form of completely soluble oxide/sulfate. The possible scenario for the copper valorization, considering arsenic and lead as limiting factors, is the separation of the FSF and PSC flows, return of the metallic/sulfide solid phase to the smelting process and recovery from the sulfate/oxide liquid phase.

  15. Pre-digestion to enhance volatile fatty acids (VFAs) concentration as a carbon source for denitrification in treatment of liquid swine manure.

    Science.gov (United States)

    Wu, Sarah Xiao; Chen, Lide; Zhu, Jun; Walquist, McKenzie; Christian, David

    2018-04-30

    Insufficient denitrification in biological treatment is often a result of the lack of a carbon source. In this study, use of the volatile fatty acids (VFAs) generated via pre-digestion as a carbon source to improve denitrification in sequencing batch reactor (SBR) treatment of liquid swine manure was investigated. The pre-digestion of swine manure was realized by storing the manure in a sealed container in room temperature and samples were taken periodically from the container to determine the VFA levels. The results showed that after 14 days of pre-digestion, the VFA level in the digested liquid was increased by 200%. A polynomial relationship for the VFA level in the digested manure with the digestion time was observed with a correlation coefficient being 0.9748. Two identical SBRs were built and operated on 8-h cycles in parallel, with one fed with pre-digested and the other raw swine manure. There were five phases included in each cycle, i.e., anaerobic (90 min), anoxic (150 min), anoxic/anaerobic (90 min), anoxic/aerobic (120 min), and settle/decant (30 min), and the feeding was split to 600 mL/200 mL and performed at the beginning of and 240 min into the cycle. The SBR fed on pre-digested swine manure achieved successful denitrification with only 0.35 mg/L nitrate left in the effluent, compared to 15.9 mg/L found in the effluent of the other SBR. Nitrite was not detected in the effluent from both SBRs. The results also indicated that there was no negative impact of feeding SBRs with the pre-digested liquid swine manure for treatment on the removal of other constituents such as total solids (TS), volatile solids (VS), suspended solids (SS), volatile suspended solids (VSS), and soluble chemical oxygen demand (COD). Therefore, anaerobic digestion as a pretreatment can be an effective way to condition liquid swine manure for SBR treatment to achieve sufficient nitrate removal.

  16. New procedure for the examination of the degradation of volatile organonitrogen compounds during the treatment of industrial effluents.

    Science.gov (United States)

    Boczkaj, Grzegorz; Makoś, Patrycja; Fernandes, Andre; Przyjazny, Andrzej

    2017-03-01

    We present a new procedure for the determination of 32 volatile organonitrogen compounds in samples of industrial effluents with a complex matrix. The procedure, based on dispersive liquid-liquid microextraction followed by gas chromatography with nitrogen-phosphorus and mass spectrometric detection, was optimized and validated. Optimization of the extraction included the type of extraction and disperser solvent, disperser solvent volume, pH, salting out effect, extraction, and centrifugation time. The procedure based on nitrogen-phosphorus detection was found to be superior, having lower limits of detection (0.0067-2.29 μg/mL) and quantitation as well as a wider linear range. The developed procedure was applied to the determination of content of volatile organonitrogen compounds in samples of raw effluents from the production of bitumens in which 13 compounds were identified at concentrations ranging from 0.15 to 10.86 μg/mL and in samples of effluents treated by various chemical methods. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Design of a treatment pilot by electro-coagulation and electro-flotation of high charged liquid effluents; Conception d'un pilote de traitement par electrocoagulation-electroflottation d'effluents liquides fortement charges

    Energy Technology Data Exchange (ETDEWEB)

    Cames, M.C.; Leclerc, J.P.; Valentin, G.; Sanchez-Calvo, L.; Lapicque, F. [Centre National de la Recherche Scientifique (CNRS-ENSIC), Lab. des Sciences du Genie Chimique, 54 - Nancy (France); Rostan, A.; Muller, P. [Centre de Recherche pour l' Environnement, l' Energie et le Dechet, Vivendi Environnement, 78 - Limay (France)

    2001-07-01

    The possibilities of the electro-coagulation and electro-flotation process has been studied on many industrial effluents by cells. The results show that the process efficiency is conditioned by the effluent nature and the dissolved aluminium quantity, what ever the initial rate of Carbon Organic Total (COT). Other parameters as the current density and the circulation speed are not significant. (A.L.B.)

  18. Rice field for the treatment of pond aquaculture effluents | Wang ...

    African Journals Online (AJOL)

    We conducted an experiment to evaluate the efficiency of rice fields in treating pond aquaculture effluent and its responses to different fertilizer treatments. Four treatments was considered in the experiment: no rice planted as the control (CT); rice planted and no fertilizer input (RE); rice planted and a rate of approximately ...

  19. Evaluation of effluents from bench-scale treatment combinations for landfill leachate in Ibadan, Nigeria.

    Science.gov (United States)

    Aluko, Olufemi Oludare; Sridhar, Mkc

    2014-01-01

    The removal of pollutants in landfill leachate was investigated using constructed wetlands, a trickling filter, alum flocculation and coagulation, and a sequencing batch reactor in various combinations. Thirteen combined operations were investigated involving three out of the four unit treatment methods in series. The study was conducted because unit operations, though achieved reductions in pollutants concentrations had effluent values above the national regulatory guideline values. The suspended solids of effluents were permissible in most treatment processes, while reductions in 5-day biochemical oxygen demand (BOD5), chemical oxygen demand (COD) and ammonia (NH3) of leachates ranged from 80% to 97%; 86% to 97% and 92% to 98% respectively. However, there were significant increases in nitrate (85%) and dissolved oxygen of treatment (218%). In addition, the characteristics of the recommended treatment sequence, involving constructed wetlands, alum and trickling filter produced effluents with reductions in colour (97%), alkalinity (97%), BOD (97%), COD (97%) and NH3 (98%), and in metals, except nickel (29% reduction from the influent values). The recommended treatment combination is suitable for effective leachate management at the landfill. The cost of constructing and operating the recommended treatment combination at the facility, for 5 years, would be NGN6,009,750.00 ($38,036.39). The performance should be monitored on site prior to full adoption if effluent characteristics remain consistently low over dry and wet seasons.

  20. Human norovirus in untreated sewage and effluents from primary, secondary and tertiary treatment processes.

    Science.gov (United States)

    Campos, Carlos J A; Avant, Justin; Lowther, James; Till, Dale; Lees, David N

    2016-10-15

    Wastewater treatments are considered important means to control the environmental transmission of human norovirus (NoV). Information about NoV concentrations in untreated and treated effluents, their seasonality and typical removal rates achieved by different treatment processes is required to assess the effectiveness of sewage treatment processes in reducing human exposure to NoV. This paper reports on a characterisation of concentrations of NoV (genogroups I and II) in untreated sewage (screened influent) and treated effluents from five full scale wastewater treatment works (WwTW) in England. Results are shown for effluent samples characteristic of primary- (primary settlement, storm tank overflows), secondary- (activated sludge, trickling filters, humus tanks) and tertiary (UV disinfection) treatments. NoV occurrence in untreated sewage varied between years. This variation was consistent with the annual variation of the virus in the community as indicated by outbreak laboratory reports. Significant differences were found between mean NoV concentrations in effluents subject to different levels of treatment. Primary settlement achieved approximately 1 log10 removal for both genogroups. Concentrations of NoV and Escherichia coli in untreated sewage were of the same order of magnitude of those in storm tank overflows. Of the secondary treatments studied, activated sludge was the most effective in removing NoV with mean log10 removals of 3.11 and 2.34 for GI and GII, respectively. The results of this study provide evidence that monitoring of NoV in raw sewage or treated effluents could provide early warning of an elevated risk for NoV and potentially help prevent outbreaks through environmental exposure. They also provide evidence that elimination of stormwater discharges and improvement of the efficiency of activated sludge for NoV removal would be effective for reducing the risk of environmental transmission. Crown Copyright © 2016. Published by Elsevier Ltd. All

  1. Radiological map evolution in the treatment of 137Cs liquid wastes by a reverse osmosis plant

    International Nuclear Information System (INIS)

    Arnal, J.M.; Sancho, M.; Verdu, G.; Gozalvez, J.M.

    2002-01-01

    As a result of an accidental 1 37C s source melting in one of the furnaces of a stainless steel production company located in Spain, a part of the factory was radioactively contaminated. LAINSA (Logistica y Acondicionamientos Industriales S.A.) company took charge of the plant decontamination process, in which 40 m 3 , approximately, of 1 37C s contaminated water with a mean activity of 300 kBq/L were generated. After some preliminary tests in which the efficiency of reverse osmosis (RO) process in the treatment of 1 37C s contaminated effluent was proved, the radioactive liquid waste was treated by a reverse osmosis plant designed by the Chemical and Nuclear Engineering Department of the Polytechnic University of Valencia (UPV), and built by LAINSA company. Membrane techniques (microfiltration, ultrafiltration, nanofiltration and reverse osmosis) have become common in the treatment of radioactive effluents having substitute conventional treatments such as evaporation and ionic exchange. The main advantages of membrane processes used for concentrating radioactive wastes are moderate operating conditions, simple apparatus, high decontamination factors and low energy consumption. The treatment was carried out by the research team UPV-LAINSA, and it consisted in the application of reverse osmosis (RO) process with the main objective of reducing the waste volume to be disposed, obtaining a treated liquid with an activity less than the legal discharge limit for 1 37C s radioisotope (300 Bq/L). When working with radioactive effluents it is very important the radiological vigilance of working areas because it ensures that neither exposed personnel nor general public receive doses above established limits. Radiological vigilance consists in determining (continuously or periodically) radiation and contamination levels in working areas and even in those places where personnel can temporarily stand. The aim of this paper is to assess the evolution of radiation levels of the

  2. Electro-coagulation applied to the treatment of industrial effluents; Electrocoagulation appliquee en traitement des effluents industriels

    Energy Technology Data Exchange (ETDEWEB)

    Laplace, C.; Leboucher, G.; Coste, M. [Anjou Recherche, Vivendi Water, 78 - Maisons-Laffitte (France)

    2001-07-01

    The electro-coagulation is a water treatment technic in electrolysis cell with double anode. In substitution to the coagulant reagent often used in water de-pollution, it realizes also the coloring decomposition, the DCO abatement and sometimes improving the sludges processing. The technic presents meanwhile some limitations as its poor treatment capacity and the necessity of a high effluent conductivity. An example of application shows that this technic is economically competitive. (A.L.B.)

  3. Assessment of the disinfection capacity and eco-toxicological impact of atmospheric cold plasma for treatment of food industry effluents.

    Science.gov (United States)

    Patange, Apurva; Boehm, Daniela; Giltrap, Michelle; Lu, Peng; Cullen, P J; Bourke, Paula

    2018-08-01

    Generation of wastewater is one of the main environmental sustainability issues across food sector industries. The constituents of food process effluents are often complex and require high energy and processing for regulatory compliance. Wastewater streams are the subject of microbiological and chemical criteria, and can have a significant eco-toxicological impact on the aquatic life. Thus, innovative treatment approaches are required to mitigate environmental impact in an energy efficient manner. Here, dielectric barrier discharge atmospheric cold plasma (ACP) was evaluated for control of key microbial indicators encountered in food industry effluent. This study also investigated the eco-toxicological impact of cold plasma treatment of the effluents using a range of aquatic bioassays. Continuous ACP treatment was applied to synthetic dairy and meat effluents. Microbial inactivation showed treatment time dependence with significant reduction in microbial populations within 120 s, and to undetectable levels after 300 s. Post treatment retention time emerged as critical control parameter which promoted ACP bacterial inactivation efficiency. Moreover, ACP treatment for 20 min achieved significant reduction (≥2 Log 10 ) in Bacillus megaterium endospores in wastewater effluent. Acute aquatic toxicity was assessed using two fish cell lines (PLHC-1 and RTG-2) and a crustacean model (Daphnia magna). Untreated effluents were toxic to the aquatic models, however, plasma treatment limited the toxic effects. Differing sensitivities were observed to ACP treated effluents across the different test bio-assays in the following order: PLHC-1 > RTG-2 ≥ D. magna; with greater sensitivity retained to plasma treated meat effluent than dairy effluent. The toxic effects were dependent on concentration and treatment time of the ACP treated effluent; with 30% cytotoxicity in D. magna and fish cells observed after 24 h of exposure to ACP treated effluent for

  4. Design parameters for waste effluent treatment unit from beverages production

    OpenAIRE

    Mona A. Abdel-Fatah; H.O. Sherif; S.I. Hawash

    2017-01-01

    Based on a successful experimental result from laboratory and bench scale for treatment of wastewater from beverages industry, an industrial and efficient treatment unit is designed and constructed. The broad goal of this study was to design and construct effluent, cost effective and high quality treatment unit. The used technology is the activated sludge process of extended aeration type followed by rapid sand filters and chlorination as tertiary treatment. Experimental results have been con...

  5. The determination of Pu-241 by liquid scintillation counting in liquid effluents of the Karlsruhe Nuclear Research Center

    International Nuclear Information System (INIS)

    Godoy, J.M.; Schuettelkopf, H.; Pimpl, M.

    1983-04-01

    A procedure was developed to measure Pu-241 by liquid scintillation counting. Sample preparation was performed by electroplating of plutonium on stainless steel planchets. To correct the selfabsorption, the linear dependence of counting efficiency in the liquid scintillation counter from the resolution in the alpha spectrometer was used. Pu-238, Pu-239+240 and Pu-241 were measured in the liquid effluents of the Karlsruhe Nuclear Research Center (KfK). The concentrations in monthly mixed samples ranged from 0.07 until 46 nCi Pu-238/m 3 , from 0.13 until 2.1 nCi Pu-239+240/m 3 and from 25 until 190 nCi Pu-241/m 3 . Between 5.4% and 41% of the plutonium content of the KfK waste water are released to the River Old Rhine. The values for the activity ratio Pu-238/Pu-239+240 are between 0.39 and 1.1 and for Pu-241/Pu-239+240 are between 11 and 300. The mean value for Pu-241/Pu-239+240 is 61. The dose exposure of the environmental population of the Karlsruhe Nuclear Research Center caused by released Pu-241 is negligible low. (orig./HP) [de

  6. Global hepatic gene expression in rainbow trout exposed to sewage effluents: a comparison of different sewage treatment technologies.

    Science.gov (United States)

    Cuklev, Filip; Gunnarsson, Lina; Cvijovic, Marija; Kristiansson, Erik; Rutgersson, Carolin; Björlenius, Berndt; Larsson, D G Joakim

    2012-06-15

    Effluents from sewage treatment plants contain a mixture of micropollutants with the potential of harming aquatic organisms. Thus, addition of advanced treatment techniques to complement existing conventional methods has been proposed. Some of the advanced techniques could, however, potentially produce additional compounds affecting exposed organisms by unknown modes of action. In the present study the aim was to improve our understanding of how exposure to different sewage effluents affects fish. This was achieved by explorative microarray and quantitative PCR analyses of hepatic gene expression, as well as relative organ sizes of rainbow trout exposed to different sewage effluents (conventionally treated, granular activated carbon, ozonation (5 or 15 mg/L), 5 mg/L ozone plus a moving bed biofilm reactor, or UV-light treatment in combination with hydrogen peroxide). Exposure to the conventionally treated effluent caused a significant increase in liver and heart somatic indexes, an effect removed by all other treatments. Genes connected to xenobiotic metabolism, including cytochrome p450 1A, were differentially expressed in the fish exposed to the conventionally treated effluents, though only effluent treatment with granular activated carbon or ozone at 15 mg/L completely removed this response. The mRNA expression of heat shock protein 70 kDa was induced in all three groups exposed to ozone-treated effluents, suggesting some form of added stress in these fish. The induction of estrogen-responsive genes in the fish exposed to the conventionally treated effluent was effectively reduced by all investigated advanced treatment technologies, although the moving bed biofilm reactor was least efficient. Taken together, granular activated carbon showed the highest potential of reducing responses in fish induced by exposure to sewage effluents. Copyright © 2012 Elsevier B.V. All rights reserved.

  7. Pilot-scale ultrafiltration testing for the F and H area effluent treatment facility

    International Nuclear Information System (INIS)

    Kessler, J.L.

    1984-01-01

    An F and H Area Effluent Treatment Facility (F/H ETF) is being designed to treat low activity aqueous effluents which are produced from F and H Area daily operations. The treatment scheme for the F/H ETF will include pretreatment (pH adjustment and filtration) followed by Reverse Osmosis and/or Ion Exchange to remove dissolved species. Several alternative treatment processes are being considered for the F/H ETF. One of the alternatives in the pretreatment step is tubular Ultrafiltration (UF), using a dynamically formed zirconium oxide membrane supported on a porous stainless steel backing. Pilot-scale testing with a single membrane module (13 ft 2 area) and 200-Area effluent simulant has demonstrated that UF is a viable filtration option for the F/H ETF. UF testing at TNX has defined the operating conditions necessary for extended operation and also demonstrated excellent filtration performance (filtrate SDI 2 /day) flux and will provide excellent pretreatment for both reverse osmosis and ion exchange. 2 refs

  8. Palm oil mill effluent treatment and utilization to ensure the sustainability of palm oil industries.

    Science.gov (United States)

    Hasanudin, U; Sugiharto, R; Haryanto, A; Setiadi, T; Fujie, K

    2015-01-01

    The purpose of this study was to evaluate the current condition of palm oil mill effluent (POME) treatment and utilization and to propose alternative scenarios to improve the sustainability of palm oil industries. The research was conducted through field survey at some palm oil mills in Indonesia, in which different waste management systems were used. Laboratory experiment was also carried out using a 5 m(3) pilot-scale wet anaerobic digester. Currently, POME is treated through anaerobic digestion without or with methane capture followed by utilization of treated POME as liquid fertilizer or further treatment (aerobic process) to fulfill the wastewater quality standard. A methane capturing system was estimated to successfully produce renewable energy of about 25.4-40.7 kWh/ton of fresh fruit bunches (FFBs) and reduce greenhouse gas (GHG) emissions by about 109.41-175.35 kgCO2e/tonFFB (CO2e: carbon dioxide equivalent). Utilization of treated POME as liquid fertilizer increased FFB production by about 13%. A palm oil mill with 45 ton FFB/hour capacity has potential to generate about 0.95-1.52 MW of electricity. Coupling the POME-based biogas digester and anaerobic co-composting of empty fruit bunches (EFBs) is capable of adding another 0.93 MW. The utilization of POME and EFB not only increases the added value of POME and EFB by producing renewable energy, compost, and liquid fertilizer, but also lowers environmental burden.

  9. Liquid secondary waste. Waste form formulation and qualification

    Energy Technology Data Exchange (ETDEWEB)

    Cozzi, A. D. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Dixon, K. L. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Hill, K. A. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); King, W. D. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Nichols, R. L. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-03-01

    The Hanford Site Effluent Treatment Facility (ETF) currently treats aqueous waste streams generated during Site cleanup activities. When the Hanford Tank Waste Treatment and Immobilization Plant (WTP) begins operations, a liquid secondary waste (LSW) stream from the WTP will need to be treated. The volume of effluent for treatment at the ETF will increase significantly. Washington River Protection Solutions is implementing a Secondary Liquid Waste Immobilization Technology Development Plan to address the technology needs for a waste form and solidification process to treat the increased volume of waste planned for disposal at the Integrated Disposal Facility IDF). Waste form testing to support this plan is composed of work in the near term to demonstrate the waste form will provide data as input to a performance assessment (PA) for Hanford’s IDF.

  10. Facility effluent monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Gleckler, B.P.

    1995-06-01

    This section of the 1994 Hanford Site Environmental Report summarizes the facility effluent monitoring programs and provides an evaluation of effluent monitoring data. These evaluations are useful in assessing the effectiveness of effluent treatment and control systems, as well as management practices.

  11. Assessment of wastewater treatment plant effluent effects on fish reproduction

    Science.gov (United States)

    Wastewater treatment plant (WWTP) effluents are known contributors of chemical mixtures into the environment. Of particular concern are endocrine-disrupting compounds that can affect hypothalamic-pituitary-gonadal axis function in exposed organisms. The present study examined t...

  12. The use of PHP in the radioactive effluent treatment in rare earth industry

    International Nuclear Information System (INIS)

    Shitang, Q.; Ruensheng, W.

    1985-01-01

    Monazite is one of the most important rare earth resources, processing monazite, however, is accompanied by radioactive effluent that needs treatment. A satisfactory treatment should be able not only to insolubilize the radioactive isotopes but also to clarify the suspension quickly and completely. In this study, out of 15 different coagulants, partially hydrolyzed polyacrylamide (PHP) of molecular weight 1000 has been chosen as the most efficient one for the clarification of the treated effluent in question. Satisfactory performance has been attained in a continuous clarifier

  13. Comparison of six sewage effluents treated with different treatment technologies-Population level responses in the harpacticoid copepod Nitocra spinipes

    International Nuclear Information System (INIS)

    Lundstroem, Elin; Bjoerlenius, Berndt; Brinkmann, Markus; Hollert, Henner; Persson, Jan-Olov; Breitholtz, Magnus

    2010-01-01

    Since conventional treatment technologies may fail in removing many micro-pollutants, there is currently a focus on the potential of additional treatment technologies for improved sewage treatment. The aim of the present study was to evaluate six different effluents from Henriksdal Sewage Treatment Plant in Stockholm, Sweden. The effluents were; conventionally treated effluent (chemical phosphorous removal in combination with an activated sludge process, including biological nitrogen removal and a sand filter), with additional treatments individually added to the conventional treatment; active carbon filtration, ozonation at 5 mg l -1 , ozonation at 15 mg l -1 , ozonation at 5 mg l -1 + moving bed biofilm reactor and irradiation with ultraviolet radiation + hydrogen peroxide. The evaluation was done by characterizing and comparing the effluents using a Lefkovitch matrix model based on a life cycle test with the harpacticoid copepod Nitocra spinipes, combined with analysis of juvenile development and survival over time. The conventionally treated effluent resulted in the most negative effects, leading to the conclusion that all additional treatments in the present study created effluents with less negative impacts on the copepod populations. The ozone treatments with the low dose treatment in particular, resulted in the overall least negative effects. Moving bed biofilm reactor combined with ozone did not improve the quality of the effluent in the sense that slightly more negative effects on the population abundance were seen for this treatment technology compared to ozonation alone. The active carbon treatment had more negative effects than the ozone treatments, most of which could possibly be explained by removal of essential metal ions. The effluent which was treated with ultraviolet radiation + hydrogen peroxide resulted in few developmental and survival effects over time, but still showed negative effects on the population level. Matrix population modeling

  14. Treated Effluent Disposal Facility

    Data.gov (United States)

    Federal Laboratory Consortium — Treated non-hazardous and non-radioactive liquid wastes are collected and then disposed of through the systems at the Treated Effluent Disposal Facility (TEDF). More...

  15. Different techniques recently used for the treatment of textile dyeing effluents: a review

    International Nuclear Information System (INIS)

    Altaf, A.; Noor, S.; Sharif, Q.M.; Najeebullah, M.

    2010-01-01

    Industrial textile processing comprises the operation of pretreatment dyeing printing and finishing. These production processes produce a substantial amount of chemical pollution. Textile finishing's wastewater, especially dye house effluent, contain different classes of organic dyes, chemicals and auxiliaries. They are colored and have extreme pH, COD and BOD values, and contain different salts, surfactants heavy metals and mineral oils. Therefore, dye bath effluents have to be treated before being discharge into the environment or municipal wastewater reservoir. This paper presents the review of different techniques currently used for the treatment of textile effluent, which are based on carbon adsorption, filtration, chemical precipitation, photo degradation, biodegradation and electrolytic chemical treatment. Membrane Technology has also been applied with the objective of recovering dyes and water. Biological processes could be adopted as a pretreatment decolorization step, combined with conventional treatment system (eg. coagulation flocculation, adsorption on activated carbon) to reduce the COD and BOD, an effective alternative for use by the textile dyeing industries. Electrochemical oxidation is an efficient process for the removal of colour and total organic carbon in reactive dyes textile wastewater. The ozonation is effective for decolorization of several dyes of different classes. Practical application of this process is feasible by treating industrial textile effluent after biological treatment. Processes using membranes technique, very interesting possibilities of separating hydrolyzed dyestuffs, dyeing auxiliaries and reuse treated wastewater in different finishing operation of textile industries. (author)

  16. 3,3',5-Triiodo-L-thyronine-like activity in effluents from domestic sewage treatment plants detected by in vitro and in vivo bioassays

    International Nuclear Information System (INIS)

    Murata, Tomonori; Yamauchi, Kiyoshi

    2008-01-01

    Thyroid system-disrupting activity in effluents from municipal domestic sewage treatment plants was detected using three in vitro assays and one in vivo assay. Contaminants in the effluents were extracted by solid-phase extraction (SPE) and eluted stepwise with different organic solvents. The majority of the thyroid system-disrupting activity was detected in the dichloromethane/methanol (1/1) fraction after SPE in all three in vitro assays: competitive assays of 3,3',5-[ 125 I]triiodo-L-thyronine ([ 125 I]T 3 ) binding to the plasma protein transthyretin (TTR assay) and thyroid hormone receptor (TR assay) and T 3 -dependent luciferase assay (Luc assay). Subsequent reverse-phase high-performance liquid chromatography (RP-HPLC) of the dichloromethane/methanol (1/1) fraction separated contaminants potent in the TR and Luc assays from those potent in the TTR assay. The contaminants potent in the TR and Luc assays were also potent in an in vivo short-term gene expression assay in Xenopus laevis (Tadpole assay). The present study demonstrated that the effluents from domestic sewage treatment plants contain contaminants with T 3 -like activity of ∼ 10 -10 M T 3 -equivalent concentration (T 3 EQ) and that the TR and Luc assays are powerful in vitro bioassays for detecting thyroid system-disrupting activity in effluents. The availability and applicability of these bioassays for screening contaminants with thyroid system-disrupting activity in the water environment are discussed

  17. Hanford Facility Dangerous Waste Permit Application, 200 Area Effluent Treatment Facility

    International Nuclear Information System (INIS)

    1993-08-01

    The 200 Area Effluent Treatment Facility Dangerous Waste Permit Application documentation consists of both Part A and a Part B permit application documentation. An explanation of the Part A revisions associated with this treatment and storage unit, including the current revision, is provided at the beginning of the Part A section. Once the initial Hanford Facility Dangerous Waste Permit is issued, the following process will be used. As final, certified treatment, storage, and/or disposal unit-specific documents are developed, and completeness notifications are made by the US Environmental Protection Agency and the Washington State Department of Ecology, additional unit-specific permit conditions will be incorporated into the Hanford Facility Dangerous Waste Permit through the permit modification process. All treatment, storage, and/or disposal units that are included in the Hanford Facility Dangerous Waste Permit Application will operate under interim status until final status conditions for these units are incorporated into the Hanford Facility Dangerous Waste Permit. The Hanford Facility Dangerous Waste Permit Application, 200 Area Effluent Treatment Facility contains information current as of May 1, 1993

  18. Hanford Facility Dangerous Waste Permit Application, 200 Area Effluent Treatment Facility

    Energy Technology Data Exchange (ETDEWEB)

    1993-08-01

    The 200 Area Effluent Treatment Facility Dangerous Waste Permit Application documentation consists of both Part A and a Part B permit application documentation. An explanation of the Part A revisions associated with this treatment and storage unit, including the current revision, is provided at the beginning of the Part A section. Once the initial Hanford Facility Dangerous Waste Permit is issued, the following process will be used. As final, certified treatment, storage, and/or disposal unit-specific documents are developed, and completeness notifications are made by the US Environmental Protection Agency and the Washington State Department of Ecology, additional unit-specific permit conditions will be incorporated into the Hanford Facility Dangerous Waste Permit through the permit modification process. All treatment, storage, and/or disposal units that are included in the Hanford Facility Dangerous Waste Permit Application will operate under interim status until final status conditions for these units are incorporated into the Hanford Facility Dangerous Waste Permit. The Hanford Facility Dangerous Waste Permit Application, 200 Area Effluent Treatment Facility contains information current as of May 1, 1993.

  19. Temporal Variation in the Estrogenicity of a Sewage Treatment Plant Effluent and its Biological Significance

    Science.gov (United States)

    This paper describes variations in the estrogenic potency of effluent from a "model" wastewater treatment plant in Duluth, MN, and explores the significance of these variations relative to sampling approaches for monitoring effluents and their toxicity to fish.

  20. Host range of antibiotic resistance genes in wastewater treatment plant influent and effluent.

    Science.gov (United States)

    Hultman, Jenni; Tamminen, Manu; Pärnänen, Katariina; Cairns, Johannes; Karkman, Antti; Virta, Marko

    2018-04-01

    Wastewater treatment plants (WWTPs) collect wastewater from various sources for a multi-step treatment process. By mixing a large variety of bacteria and promoting their proximity, WWTPs constitute potential hotspots for the emergence of antibiotic resistant bacteria. Concerns have been expressed regarding the potential of WWTPs to spread antibiotic resistance genes (ARGs) from environmental reservoirs to human pathogens. We utilized epicPCR (Emulsion, Paired Isolation and Concatenation PCR) to detect the bacterial hosts of ARGs in two WWTPs. We identified the host distribution of four resistance-associated genes (tetM, int1, qacEΔ1and blaOXA-58) in influent and effluent. The bacterial hosts of these resistance genes varied between the WWTP influent and effluent, with a generally decreasing host range in the effluent. Through 16S rRNA gene sequencing, it was determined that the resistance gene carrying bacteria include both abundant and rare taxa. Our results suggest that the studied WWTPs mostly succeed in decreasing the host range of the resistance genes during the treatment process. Still, there were instances where effluent contained resistance genes in bacterial groups not carrying these genes in the influent. By permitting exhaustive profiling of resistance-associated gene hosts in WWTP bacterial communities, the application of epicPCR provides a new level of precision to our resistance gene risk estimates.

  1. Production of demineralized water for use in thermal power stations by advanced treatment of secondary wastewater effluent.

    Science.gov (United States)

    Katsoyiannis, Ioannis A; Gkotsis, Petros; Castellana, Massimo; Cartechini, Fabricio; Zouboulis, Anastasios I

    2017-04-01

    The operation and efficiency of a modern, high-tech industrial full-scale water treatment plant was investigated in the present study. The treated water was used for the supply of the boilers, producing steam to feed the steam turbine of the power station. The inlet water was the effluent of municipal wastewater treatment plant of the city of Bari (Italy). The treatment stages comprised (1) coagulation, using ferric chloride, (2) lime softening, (3) powdered activated carbon, all dosed in a sedimentation tank. The treated water was thereafter subjected to dual-media filtration, followed by ultra-filtration (UF). The outlet of UF was subsequently treated by reverse osmosis (RO) and finally by ion exchange (IX). The inlet water had total organic carbon (TOC) concentration 10-12 mg/L, turbidity 10-15 NTU and conductivity 3500-4500 μS/cm. The final demineralized water had TOC less than 0.2 mg/L, turbidity less than 0.1 NTU and conductivity 0.055-0.070 μS/cm. Organic matter fractionation showed that most of the final DOC concentration consisted of low molecular weight neutral compounds, while other compounds such as humic acids or building blocks were completely removed. It is notable that this plant was operating under "Zero Liquid Discharge" conditions, implementing treatment of any generated liquid waste. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Treatment alternatives of liquid radioactive waste containing uranium in phosphoric acid

    International Nuclear Information System (INIS)

    Bustamante Escobedo, Mauricio

    2003-01-01

    The UGDR, receives annually 100 [l] of liquid radioactive waste containing, highly acid (pH=0) uranium in phosphoric acid from the Laboratory of Chemical Analysis. This waste must be chemically and radiologically decontaminated before it can be discharged in accordance with local environmental standards. Chemical precipitation and evaporation test were carried out to define the operating conditions for the radiological decontamination of this radioactive waste and to obtain a solid waste that can be conditioned in a cement matrix. The evaporation process generates excellent rates of volume reduction, over 80%, but generates a pulp that is hard handle when submitted to a drying process. Chemical precipitation generates good results for decontaminating these solutions and reducing volume (above 50%) to obtain a uranium free effluent. The treatment with calcium carbonate generated an effluent with a low concentration of polluting agents. A preliminary test was carried out condition these solids in a cement matrix, using ratios of 0.45 waste/cement and 2 of water/cement. The mix prepared with waste from the sodium hydroxide treatment had low mechanical resistance resulting from the saline incrustations. The waste from the calcium carbonate treatment was very porous due to the water evaporation from the highly exothermic reaction between the waste and the cement. The mix of the calcium carbonate generated waste and the cement matrix needs to be optimized, since it generates favorable conditions for adhering with the cement matrix (au)

  3. On-line liquid-effluent monitoring of sewage at Lawrence Livermore National Laboratory

    International Nuclear Information System (INIS)

    Dreicer, M.; Cate, J.L.; Rueppel, D.W.; Huntzinger, C.J.; Gonzalez, M.A.

    1982-01-01

    An automatic on line sewage effluent monitoring system has been developed. A representative fraction of the total waste stream leaving the site is monitored for pH, radiation, and metals as it passes through a detection assembly. This assembly consists of an industrial pH probe, NaI radiation detectors, and an x-ray fluorescence metal detector. A microprocessor collects, reduces and analyzes the data to determine if the levels are acceptable by established environmental limits. Currently, if preset levels are exceeded, a sample of the suspect sewage is automatically collected for further analysis, and an alarm is sent to a station where personnel can be alerted to respond on a 24-hour basis. Since at least four hours pass before LLNL effluent reaches the treatment plant, sufficient time is available to alert emergency personnel, evaluate the situation, and if necessary arrange for diversion of the material to emergency holding basins at the treatment plant. Information on the current system is presented, and progress is reported in developing an on-line tritium monitor as an addition to the assembly

  4. Calculation of risk-based detection limits for radionuclides in the liquid effluents from Korean nuclear power plants

    International Nuclear Information System (INIS)

    Cheong, Jae Hak

    2017-01-01

    In order to review if present detection limits of radionuclides in liquid effluent from nuclear power plants are effective enough to warrant compliance with regulatory discharge limits, a risk-based approach is developed to derive a new detection limit for each radionuclide based on radiological criteria. Equations and adjustment factors are also proposed to discriminate the validity of the detection limits for multiple radionuclides in the liquid effluent with or without consideration of the nuclide composition. From case studies to three nuclear power plants in Korea with actual operation data from 2006 to 2015, the present detection limits have turned out to be effective for Hanul Unit 1 but may not be sensitive enough for Kori Unit 1 (8 out of 14 radionuclides) and Wolsong Unit 1 (9 out of 42 radionuclides). However, it is shown that the present detection limits for the latter two nuclear power plants can be justified, if credit is given to the radionuclide composition. Otherwise, consideration should be given to adjustment of the present detection limits. The risk-based approach of this study can be used to determine the validity of established detection limits of a specific nuclear power plant. (author)

  5. Comparison of six sewage effluents treated with different treatment technologies--population level responses in the harpacticoid copepod Nitocra spinipes.

    Science.gov (United States)

    Lundström, Elin; Björlenius, Berndt; Brinkmann, Markus; Hollert, Henner; Persson, Jan-Olov; Breitholtz, Magnus

    2010-03-01

    Since conventional treatment technologies may fail in removing many micro-pollutants, there is currently a focus on the potential of additional treatment technologies for improved sewage treatment. The aim of the present study was to evaluate six different effluents from Henriksdal Sewage Treatment Plant in Stockholm, Sweden. The effluents were; conventionally treated effluent (chemical phosphorous removal in combination with an activated sludge process, including biological nitrogen removal and a sand filter), with additional treatments individually added to the conventional treatment; active carbon filtration, ozonation at 5 mg l(-1), ozonation at 15 mg l(-1), ozonation at 5 mg l(-1)+moving bed biofilm reactor and irradiation with ultraviolet radiation+hydrogen peroxide. The evaluation was done by characterizing and comparing the effluents using a Lefkovitch matrix model based on a life cycle test with the harpacticoid copepod Nitocra spinipes, combined with analysis of juvenile development and survival over time. The conventionally treated effluent resulted in the most negative effects, leading to the conclusion that all additional treatments in the present study created effluents with less negative impacts on the copepod populations. The ozone treatments with the low dose treatment in particular, resulted in the overall least negative effects. Moving bed biofilm reactor combined with ozone did not improve the quality of the effluent in the sense that slightly more negative effects on the population abundance were seen for this treatment technology compared to ozonation alone. The active carbon treatment had more negative effects than the ozone treatments, most of which could possibly be explained by removal of essential metal ions. The effluent which was treated with ultraviolet radiation+hydrogen peroxide resulted in few developmental and survival effects over time, but still showed negative effects on the population level. Matrix population modeling proved a

  6. Comparison of six sewage effluents treated with different treatment technologies-Population level responses in the harpacticoid copepod Nitocra spinipes

    Energy Technology Data Exchange (ETDEWEB)

    Lundstroem, Elin, E-mail: elin.lundstrom@itm.su.se [Stockholm University, Department of Applied Environmental Science (ITM), S-106 91 Stockholm (Sweden); Bjoerlenius, Berndt [Stockholm Water Company, S-106 36 Stockholm (Sweden); Brinkmann, Markus; Hollert, Henner [RWTH Aachen University, Institute for Environmental Research, Department of Ecosystem Analysis, D-520 74 Aachen (Germany); Persson, Jan-Olov [Stockholm University, Department of Mathematics, S-106 91 Stockholm (Sweden); Breitholtz, Magnus [Stockholm University, Department of Applied Environmental Science (ITM), S-106 91 Stockholm (Sweden)

    2010-03-01

    Since conventional treatment technologies may fail in removing many micro-pollutants, there is currently a focus on the potential of additional treatment technologies for improved sewage treatment. The aim of the present study was to evaluate six different effluents from Henriksdal Sewage Treatment Plant in Stockholm, Sweden. The effluents were; conventionally treated effluent (chemical phosphorous removal in combination with an activated sludge process, including biological nitrogen removal and a sand filter), with additional treatments individually added to the conventional treatment; active carbon filtration, ozonation at 5 mg l{sup -1}, ozonation at 15 mg l{sup -1}, ozonation at 5 mg l{sup -1} + moving bed biofilm reactor and irradiation with ultraviolet radiation + hydrogen peroxide. The evaluation was done by characterizing and comparing the effluents using a Lefkovitch matrix model based on a life cycle test with the harpacticoid copepod Nitocra spinipes, combined with analysis of juvenile development and survival over time. The conventionally treated effluent resulted in the most negative effects, leading to the conclusion that all additional treatments in the present study created effluents with less negative impacts on the copepod populations. The ozone treatments with the low dose treatment in particular, resulted in the overall least negative effects. Moving bed biofilm reactor combined with ozone did not improve the quality of the effluent in the sense that slightly more negative effects on the population abundance were seen for this treatment technology compared to ozonation alone. The active carbon treatment had more negative effects than the ozone treatments, most of which could possibly be explained by removal of essential metal ions. The effluent which was treated with ultraviolet radiation + hydrogen peroxide resulted in few developmental and survival effects over time, but still showed negative effects on the population level. Matrix population

  7. Extraction by means of emulsified liquid membranes; Extraction par membranes liquides emulsionnees (MLE)

    Energy Technology Data Exchange (ETDEWEB)

    Pareau, D.; Stambouli, M. [Ecole Centrale de Paris, 75 (France)

    2006-12-15

    It is an alternative of the liquid-liquid extraction process where extraction and stripping are simultaneously carried out. The stripping solution is dispersed in the solvent in micro-droplets. This emulsion, stabilised by a surface-active agent, is then dispersed in the liquid to be treated and, during that step, the metal is transferred to the stripping solution, moving through the solvent which operates as an organic membrane. The paper describes in detail the mechanism of the process, its advantages and its disadvantages. Its field of applications is wide, but only a few units are now industrially in operation, most of them exists only at the pilot scale. It is particularly adapted for the treatment of effluents with a very low content in metallic impurities. As examples, the paper describes the recovery of zinc from viscose plant effluents (Lenzing plant, Austria) and the removal of free cyanide ions and cyanide metallic complexes (pilot scale). (authors)

  8. Canadian uranium mines and mills evolution of regulatory expectations and requirements for effluent treatment

    International Nuclear Information System (INIS)

    LeClair, J.; Ashley, F.

    2006-01-01

    The regulation of uranium mining in Canada has changed over time as our understanding and concern for impacts on both human and non-human biota has evolved. Since the mid-1970s and early 1980s, new uranium mine and mill developments have been the subject of environmental assessments to assess and determine the significance of environmental effects throughout the project life cycle including the post-decommissioning phase. Water treatment systems have subsequently been improved to limit potential effects by reducing the concentration of radiological and non-radiological contaminants in the effluent discharge and the total loadings to the environment. This paper examines current regulatory requirements and expectations and how these impact uranium mining/milling practices. It also reviews current water management and effluent treatment practices and performance. Finally, it examines the issues and challenges for existing effluent treatment systems and identifies factors to be considered in optimizing current facilities and future facility designs. (author)

  9. Fungal Biosorption, An Innovative Treatment for the Decolourisation and Detoxification of Textile Effluents

    Directory of Open Access Journals (Sweden)

    Antonella Pannocchia

    2010-08-01

    Full Text Available Textile effluents are among the most difficult-to-treat wastewaters, due to their considerable amount of recalcitrant and toxic substances. Fungal biosorption is viewed as a valuable additional treatment for removing pollutants from textile wastewaters. In this study the efficiency of Cunninghamella elegans biomass in terms of contaminants, COD and toxicity reduction was tested against textile effluents sampled in different points of wastewater treatment plants. The results showed that C. elegans is a promising candidate for the decolourisation and detoxification of textile wastewaters and its versatility makes it very competitive compared with conventional sorbents adopted in industrial processes.

  10. Facility effluent monitoring plan for the tank farms facilities

    International Nuclear Information System (INIS)

    Crummel, G.M.; Gustavson, R.D.; Kenoyer, J.L.; Moeller, M.P.

    1991-11-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan is the first annual report. It shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated as a minimum three years. A variety of liquid wastes are generated in processing treatment, and disposal operations throughout the Hanford Site. The Tank Farms Project serves a major role in Hanford Site waste management activities as the temporary repository for these wastes. Stored wastes include hazardous components regulated under the Resource Conservation and Recovery Act of 1976 (RCRA) and as by-product material regulated under the Atomic Energy Act of 1954. A total of 177 single- and double-shell tanks (SST and DST) have been constructed in the 200 East and 200 West Areas of the Hanford Site. These facilities were constructed to various designs from 1943 to 1986. The Tank Farms Project is comprised of these tanks along with various transfer, receiving, and treatment facilities

  11. Remediation of textile effluents by membrane based treatment techniques: a state of the art review.

    Science.gov (United States)

    Dasgupta, Jhilly; Sikder, Jaya; Chakraborty, Sudip; Curcio, Stefano; Drioli, Enrico

    2015-01-01

    The textile industries hold an important position in the global industrial arena because of their undeniable contributions to basic human needs satisfaction and to the world economy. These industries are however major consumers of water, dyes and other toxic chemicals. The effluents generated from each processing step comprise substantial quantities of unutilized resources. The effluents if discharged without prior treatment become potential sources of pollution due to their several deleterious effects on the environment. The treatment of heterogeneous textile effluents therefore demands the application of environmentally benign technology with appreciable quality water reclamation potential. These features can be observed in various innovative membrane based techniques. The present review paper thus elucidates the contributions of membrane technology towards textile effluent treatment and unexhausted raw materials recovery. The reuse possibilities of water recovered through membrane based techniques, such as ultrafiltration and nanofiltration in primary dye houses or auxiliary rinse vats have also been explored. Advantages and bottlenecks, such as membrane fouling associated with each of these techniques have also been highlighted. Additionally, several pragmatic models simulating transport mechanism across membranes have been documented. Finally, various accounts dealing with techno-economic evaluation of these membrane based textile wastewater treatment processes have been provided. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Treatment of low level radioactive liquid waste containing appreciable concentration of TBP degraded products.

    Science.gov (United States)

    Valsala, T P; Sonavane, M S; Kore, S G; Sonar, N L; De, Vaishali; Raghavendra, Y; Chattopadyaya, S; Dani, U; Kulkarni, Y; Changrani, R D

    2011-11-30

    The acidic and alkaline low level radioactive liquid waste (LLW) generated during the concentration of high level radioactive liquid waste (HLW) prior to vitrification and ion exchange treatment of intermediate level radioactive liquid waste (ILW), respectively are decontaminated by chemical co-precipitation before discharge to the environment. LLW stream generated from the ion exchange treatment of ILW contained high concentrations of carbonates, tributyl phosphate (TBP) degraded products and problematic radio nuclides like (106)Ru and (99)Tc. Presence of TBP degraded products was interfering with the co-precipitation process. In view of this a modified chemical treatment scheme was formulated for the treatment of this waste stream. By mixing the acidic LLW and alkaline LLW, the carbonates in the alkaline LLW were destroyed and the TBP degraded products got separated as a layer at the top of the vessel. By making use of the modified co-precipitation process the effluent stream (1-2 μCi/L) became dischargeable to the environment after appropriate dilution. Based on the lab scale studies about 250 m(3) of LLW was treated in the plant. The higher activity of the TBP degraded products separated was due to short lived (90)Y isotope. The cement waste product prepared using the TBP degraded product was having good chemical durability and compressive strength. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. Operability test procedure for the TK-900 effluent monitoring station

    International Nuclear Information System (INIS)

    Weissenfels, R.D.

    1994-01-01

    This procedure will verify that the 221-B liquid effluent monitoring system, installed near the east end of the 6-in. chemical sewer header, functions as intended by design. TK-900B was installed near stairwell 3 in the 221-B electrical gallery by Project W-007H. The system is part of BAT/AKART for the BCE liquid effluent system

  14. Treatment and utilization of septic tank effluent using vertical-flow constructed wetlands and vegetable hydroponics.

    Science.gov (United States)

    Cui, Li-Hua; Luo, Shi-Ming; Zhu, Xi-Zhen; Liu, Ying-Hu

    2003-01-01

    Vertical flow constructed wetlands is a typical ecological sanitation system for sewage treatment. The removal rates for COD, BOD5, SS, TN, and TP were 60%, 80%, 74%, 49% and 79%, respectively, when septic tank effluent was treated by vertical flow filter. So the concentration of COD and BOD5 in the treated effluent could meet the quality standard for irrigation water. After that the treated effluent was used for hydroponic cultivation of water spinach and romaine lettuce, the removal efficiencies of the whole system for COD, BOD5, SS, TN and TP were 71.4%, 97.5%, 96.9%, 86.3%, and 87.4%, respectively. And it could meet the integrated wastewater discharge standard for secondary biological treatment plant. It was found that using treated effluent for hydroponic cultivation of vegetables could reduce the nitrate content in vegetables. The removal rates for total bacteria and coliform index by using vertical flow bed system with cinder substrate were 80%-90% and 85%-96%, respectively.

  15. Control of Reactive Species Generated by Low-frequency Biased Nanosecond Pulse Discharge in Atmospheric Pressure Plasma Effluent

    Science.gov (United States)

    Takashima, Keisuke; Kaneko, Toshiro

    2016-09-01

    The control of hydroxyl radical and the other gas phase species generation in the ejected gas through air plasma (air plasma effluent) has been experimentally studied, which is a key to extend the range of plasma treatment. Nanosecond pulse discharge is known to produce high reduced electric field (E/N) discharge that leads to efficient generation of the reactive species than conventional low frequency discharge, while the charge-voltage cycle in the low frequency discharge is known to be well-controlled. In this study, the nanosecond pulse discharge biased with AC low frequency high voltage is used to take advantages of these discharges, which allows us to modulate the reactive species composition in the air plasma effluent. The utilization of the gas-liquid interface and the liquid phase chemical reactions between the modulated long-lived reactive species delivered from the air plasma effluent could realize efficient liquid phase chemical reactions leading to short-lived reactive species production far from the air plasma, which is crucial for some plasma agricultural applications.

  16. Treatment of a Textile Effluent from Dyeing with Cochineal Extracts Using Trametes versicolor Fungus

    Directory of Open Access Journals (Sweden)

    Gabriela Arroyo-Figueroa

    2011-01-01

    Full Text Available Trametes versicolor (Tv fungus can degrade synthetic dyes that contain azo groups, anthraquinone, triphenylmethane polymers, and heterocyclic groups. However, no references have been found related to the degradation of natural dyes, such as the carminic acid that is contained in the cochineal extract. Experiments to determine the decolorization of the effluent used in the cotton dyeing process with cochineal extract by means of Tv fungus were done. Treatments to determine decolorization in the presence or absence of Kirk's medium, glucose, and fungus, with an addition of 50% (v v-1 of nonsterilized effluent were performed. Physicochemical characterization was performed at the start and end of the treatment. Degradation kinetics were determined. A direct relationship was found between the dry weight of fungi, pH, and the decolorization system, with higher decolorization at lower pH levels (pH ~4.3. High decolorization (81% ± 0.09; 88% ± 0.17; and 99% ± 0.04 for three of the eight treatments (Kirk's medium without glucose, Kirk's medium with glucose, and without medium with glucose, respectively was found. Toxicity tests determined an increase in the initial effluent toxicity (7.33 TU compared with the final treatment (47.73 TU in a period of 11 days. For this system, a degradation sequence of the carminic acid structure present in the effluent by the Tv fungus is suggested, in which it is seen that metabolites still containing aromatic structures are generated.

  17. Treatment of a textile effluent from dyeing with cochineal extracts using Trametes versicolor fungus.

    Science.gov (United States)

    Arroyo-Figueroa, Gabriela; Ruiz-Aguilar, Graciela M L; López-Martínez, Leticia; González-Sánchez, Guillermo; Cuevas-Rodríguez, Germán; Rodríguez-Vázquez, Refugio

    2011-05-05

    Trametes versicolor (Tv) fungus can degrade synthetic dyes that contain azo groups, anthraquinone, triphenylmethane polymers, and heterocyclic groups. However, no references have been found related to the degradation of natural dyes, such as the carminic acid that is contained in the cochineal extract. Experiments to determine the decolorization of the effluent used in the cotton dyeing process with cochineal extract by means of Tv fungus were done. Treatments to determine decolorization in the presence or absence of Kirk's medium, glucose, and fungus, with an addition of 50% (v v-1) of nonsterilized effluent were performed. Physicochemical characterization was performed at the start and end of the treatment. Degradation kinetics were determined. A direct relationship was found between the dry weight of fungi, pH, and the decolorization system, with higher decolorization at lower pH levels (pH ~4.3). High decolorization (81% ± 0.09; 88% ± 0.17; and 99% ± 0.04) for three of the eight treatments (Kirk's medium without glucose, Kirk's medium with glucose, and without medium with glucose, respectively) was found. Toxicity tests determined an increase in the initial effluent toxicity (7.33 TU) compared with the final treatment (47.73 TU) in a period of 11 days. For this system, a degradation sequence of the carminic acid structure present in the effluent by the Tv fungus is suggested, in which it is seen that metabolites still containing aromatic structures are generated.

  18. Operation and effluent quality of a small rural wastewater treatment ...

    African Journals Online (AJOL)

    The objective of this study was to evaluate the impact of effluent and sludge discharges of an abattoir wastewater treatment plant (WWTP) on the operation of a municipal aerated pond WWTP. Experiments were carried out in Cervera WWTP, located in northeastern Spain, which comprises four ponds operating in series.

  19. Assessment of wastewater treatment plant effluent on fish reproduction utilizing the adverse outcome pathway conceptual framework

    Science.gov (United States)

    Wastewater treatment plant (WWTP) effluents are a known contributor of chemical mixture inputs into the environment. Whole effluent testing guidelines were developed to screen these complex mixtures for acute toxicity. However, efficient and cost-effective approaches for screenin...

  20. Changes in the Treatment of Some Physico-Chemical Properties of Cassava Mill Effluents Using Saccharomyces cerevisiae.

    Science.gov (United States)

    Izah, Sylvester Chibueze; Bassey, Sunday Etim; Ohimain, Elijah Ige

    2017-10-16

    Cassava is majorly processed into gari by smallholders in Southern Nigeria. During processing, large volume of effluents are produced in the pressing stage of cassava tuber processing. The cassava mill effluents are discharged into the soil directly and it drain into nearby pits, surface water, and canals without treatment. Cassava mill effluents is known to alter the receiving soil and water characteristics and affects the biota in such environments, such as fishes (water), domestic animals, and vegetation (soil). This study investigated the potential of Saccharomyces cerevisiae to be used for the treatment of some physicochemical properties of cassava mill effluents. S. cerevisiae was isolated from palm wine and identified based on conventional microbiological techniques, viz. morphological, cultural, and physiological/biochemical characteristics. The S. cerevisiae was inoculated into sterile cassava mill effluents and incubated for 15 days. Triplicate samples were withdrawn from the setup after the fifth day of treatment. Portable equipment was used to analyze the in-situ parameters, viz. total dissolved solids (TDS), pH, dissolved oxygen (DO), conductivity, salinity, and turbidity. Anions (nitrate, sulphate, and phosphate) and chemical oxygen demand (COD) were analyzed using spectrophotometric and open reflux methods respectively. Results showed a decline of 37.62%, 22.96%, 29.63%, 20.49%, 21.44%, 1.70%, 53.48%, 68.00%, 100%, and 74.48% in pH, conductivity, DO, TDS, salinity, sulphate, nitrate, phosphate, and COD levels respectively, and elevation of 17.17% by turbidity. The study showed that S. cerevisiae could be used for the treatment of cassava mill effluents prior to being discharged into the environment so as to reduce the pollution or contamination and toxicity levels.

  1. Packed bed reactor treatment of liquid hazardous and mixed wastes

    International Nuclear Information System (INIS)

    Tennant, R.A.; Wantuck, P.J.; Vargas, R.

    1992-01-01

    We are developing thermal-based packed bed reactor (PBR) technology as an alternative to incineration for treatment of hazardous organic liquid wastes. The waste streams targeted by this technology are machining fluids contaminated with chlorocarbons and/or chlorofluorocarbons and low levels of plutonium or tritium The PBR offers several distinct advantages including simplistic design, rugged construction, ambient pressure processing, economical operations, as well as ease of scalability and maintainability. In this paper, we provide a description of the apparatus as well as test results using prepared mixtures of machining oils/emulsions with trichloroethylene (TCE), carbon tetrachloride (CCl 4 ), trichloroethane (TCA), and Freon TF. The current treatment system is configured as a two stage device with the PBR (1st stage) coupled to a silent discharge plasma (SDP) cell. The SDP serves as a second stage for further treatment of the gaseous effluent from the PBR. One of the primary advantages of this two stage system is that its suitability for closed loop operation where radioactive components are well contained and even CO 2 is not released to the environment

  2. Effect of exposure to wastewater treatment plant effluent on fathead minnow reproduction

    Data.gov (United States)

    U.S. Environmental Protection Agency — Adult fathead minnows were exposed to dilutions of a historically estrogenic wastewater treatment plant effluent in a 21-d reproduction study. This dataset is...

  3. Decontamination factor Improvement and Waste Reduction of Full-scaled Evaporation System for Liquid Radioactive Waste Treatment

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ki Tae; Ju, Young Jong; Seol, Jeung Gun; Cho, Nam Chan [KNF, Daejeon (Korea, Republic of); Ha, Dong Hwan; Kim, Yun Kwan [Jeontech Co., Suwon (Korea, Republic of)

    2016-05-15

    Liquid radioactive waste is produced from nuclear power plants, nuclear research centers, radiopharmaceuticals and nuclear fuel fabrication plants, etc. Ion-exchange, chemical precipitation, evaporation, filtration, liquid/solid extraction and centrifugal are applied to treat the liquid waste. Chemical precipitation requires low capital and operation cost. However, it produces large amount of secondary waste and has low DF (decontamination factor). Evaporation process removes variety of radionuclides in high DF. But, it also has problems in scaling and foaming [3, 4]. In this study, it is investigated that the effect of switching lime precipitation and centrifugal processes to evaporation system for improvement of removal efficiency and decrease of waste in full-scaled radioactive wastewater treatment plant. By swapping full-scaled wastewater treatment system from the centrifugal and the lime precipitation to the evaporator and the crystallizer in the nuclear fuel fabrication plant, it was possible to increase removal efficiency and to minimize waste productivity. Radioactivity concentration of effluent is decreased from 0.01 Bq/mL to ND level. Besides, waste production was reduced from 15 drums/yr to 2 drums/yr (87%).

  4. Effluent Treatment Technologies in the Iron and Steel Industry - A State of the Art Review.

    Science.gov (United States)

    Das, Pallabi; Mondal, Gautam C; Singh, Siddharth; Singh, Abhay K; Prasad, Bably; Singh, Krishna K

    2018-05-01

      Iron and steel industry is the principal driving force propelling economic and technological growth of a nation. However, since its inception this industry is associated with widespread environmental pollution and enormous water consumption. Different units of a steel plant discharge effluents loaded with toxic, hazardous pollutants, and unutilized components which necessitates mitigation. In this paper, pollutant removal efficiency, effluent volume product quality, and economic feasibility of existing treatments are studied vis-à-vis their merits, demerits, and innovations to access their shortcomings which can be overcome with new technology to identify future research directions. While conventional methods are inadequate for complete remediation and water reclamation, the potential of advanced treatments, like membrane separation, remains relatively untapped. It is concluded that integrated systems combining membrane separation with chemical treatments can guarantee a high degree of contaminant removal, reusability of effluents concurrently leading to process intensification ensuring ecofriendliness and commercial viability.

  5. Treatment of radioactive effluents by concentration in an installation with natural evaporation

    International Nuclear Information System (INIS)

    Wormser, G.; Chauvet, P.

    1963-01-01

    This document reports natural evaporation tests performed in Cadarache, notably to adapt the equipment to the treatment of radioactive effluents. After a brief description of the apparatus principle and operation, the authors propose a summary of the first test campaign (test apparatus, results), indicate modifications brought to the apparatus by taking the first results into account, and propose a detailed discussion of results obtained during the second test campaign. They finally discuss the possibility of concentration of effluents by means of natural evaporation [fr

  6. Characterization of secondary treated effluents for tertiary membrane filtration and water recycling

    KAUST Repository

    Ayache, C.; Pidou, Marc; Gernjak, Wolfgang; Poussade, Yvan; Croue, Jean-Philippe; Tazi-Pain, Annie; Keller, Jurg R.

    2012-01-01

    This study evaluates the impacts of water quality from three different secondary effluents on low pressure membrane fouling. Effluent organic matter (EfOM) has been reported by previous studies as responsible for membrane fouling. However, the contribution of the different components of EfOM to membrane fouling is still not well understood. In order to improve and optimize treatment processes, characterization and quantification of the organic matter are important. The characterization methods used in this study are liquid chromatography coupled with an organic detector (LC-OCD) and excitation emission matrix fluorescence spectroscopy (EEM). A bench-scale hollow fibre membrane system was used to identify the type of fouling depending on the feed water quality. Results showed no measurable dissolved organic carbon removal by the membranes for the three secondary effluents. Biopolymers and humic-like substances found in different proportions in the three effluents were partially retained by the membranes and were identified to contribute significantly to the flux decline of the low pressure membranes. The observed fouling was determined to be reversible by hydraulic backwashing for two effluents and only by chemical cleaning for the third effluent. © IWA Publishing 2012.

  7. Characterization of secondary treated effluents for tertiary membrane filtration and water recycling

    KAUST Repository

    Ayache, C.

    2012-06-01

    This study evaluates the impacts of water quality from three different secondary effluents on low pressure membrane fouling. Effluent organic matter (EfOM) has been reported by previous studies as responsible for membrane fouling. However, the contribution of the different components of EfOM to membrane fouling is still not well understood. In order to improve and optimize treatment processes, characterization and quantification of the organic matter are important. The characterization methods used in this study are liquid chromatography coupled with an organic detector (LC-OCD) and excitation emission matrix fluorescence spectroscopy (EEM). A bench-scale hollow fibre membrane system was used to identify the type of fouling depending on the feed water quality. Results showed no measurable dissolved organic carbon removal by the membranes for the three secondary effluents. Biopolymers and humic-like substances found in different proportions in the three effluents were partially retained by the membranes and were identified to contribute significantly to the flux decline of the low pressure membranes. The observed fouling was determined to be reversible by hydraulic backwashing for two effluents and only by chemical cleaning for the third effluent. © IWA Publishing 2012.

  8. System for effluent treatment with particular reference to the reuse of the water

    Energy Technology Data Exchange (ETDEWEB)

    Rolke, O.E.

    1979-01-01

    A system for effluent treatment with particular reference to the reuse of the water consisted of biological treatment, flocculation, filtration, activated carbon adsorption and ion exchange. Such a multistage system is needed to treat wastewaters from coal gasification and coke-oven plants since the effluents, derived from cooling water for scrubbers, waste heat boilers, and heat exchangers, contains high levels of phenols, fatty acids, ammonia, suspended tar oil, and coal particles. A pilot plant, which has been built based on the system, will produce water of sufficient quality for reuse as cooling water. It is hoped that cooling systems for coal gasification plants can be 90% closed circuit.

  9. Performance of cellulose acetate membrane with different additives for palm oil mill effluent (POME) liquid waste treatment

    Science.gov (United States)

    Aprilia, N. A. S.; Fauzi; Azmi, N.; Najwan, N.; Amin, A.

    2018-03-01

    Performance of cellulose acetate membrane for treatment of POME liquid has studied with different additives. Cellulose acetate membranes were prepared with different additive ie formamide and polyethylene glycol and used acetone as solvent. The function of formamide and polyethylene glycol (PEG) is to increase the porosity of the membrane surface. Performance of the membrane were included SEM, FT-IR and coefficient permeability. Membrane performance has been performed for percent rejection of total suspended solid (TSS) and turbidity of POME liquid waste. Cellulose acetate with formamide shows an increased percentage of rejection in removing TSS and turbidity than cellulose acetate with PEG.

  10. Pre-treatment and membrane ultrafiltration using treated palm oil mill effluent (POME

    Directory of Open Access Journals (Sweden)

    Wong Pui Wah

    2002-11-01

    Full Text Available Treatment of palm oil mill effluent (POME has always been a topic of research in Malaysia. This effluent that is extremely rich in organic content needs to be properly treated to minimize environmental hazards before it is released into watercourses. The common practice for treating POME in Malaysia involves a combination of aerobic and anaerobic methods. The purpose of tertiary treatment is to allow the treated water to be reused in the mill operations for other purposes such as feed water. The proposed treatment will also ensure the industry to meet a more stringent discharge standard in terms of the BOD, COD and nitrogen values. In this study membrane ultrafiltration is used as the tertiary treatment method. Before the actual membrane operation was conducted, the samples were pre-treated using three separate method namely filtration, centrifugation and coagulation. It was found that the combination of filtrationultrafiltration treatment POME produced the best-treated sample quality in terms of pollutant contents elimination, namely % BOD, % COD and % nitrogen removal.

  11. Development of work on the treatment of radioactive wastes at IPR (Instituto de Pesquisas Radioativas, Minas Gerais, Brazil)

    International Nuclear Information System (INIS)

    Soares, M.L.L.; Gomes, H.

    1974-01-01

    The work developed until 1974 by the group of IPR (Instituto de Pesquisas Radioativas - MG, Brazil) responsible for the treatment of radioative wastes, is presented. The evaporation of liquid effluents of medium level activity, the treatment of gaseous effluents, the vitrification of high level liquid wastes and the sites for the final disposal of wastes are discussed [pt

  12. Microbiological characterization of winery effluents: an inventory of the sites for different treatment systems.

    Science.gov (United States)

    Jourjon, F; Khaldi, S; Reveillere, M; Thibault, C; Poulard, A; Chretien, P; Bednar, J

    2005-01-01

    In a more and more regulated and socially pressured environment, the durable management of winery effluents must take into account their characteristics and their potential impact on their natural setting. The object of this exploratory study is to establish an inventory of the microbiological composition of winery effluents coming from different treatment systems. We have observed that winery effluents are charged with micro-organisms, by a factor that ranges from 10(5) to 10(8) UFC/ml, and that the level of "microbiological pollution" is independent of the type of system. The composition of the flora is closely tied to the time of year and therefore to winery activities, so certain micro-organisms will be favoured in certain periods and others will have a tendency to decrease. We have seen that from one year to another our observations remain identical; the flora equilibrium therefore occurs systematically and naturally. Faecal germs are found in very small quantities in winery effluent treatment systems. They represent minor sanitary risks. Good correlations were observed between some micro-organisms and some physical-chemical parameters (COD). It is, however, difficult to use these "easy-to-measure" parameters as reliable markers of certain microbial populations.

  13. Analysis of adaptability of radioactive liquid effluent discharge under normal condition of inland nuclear power plant

    International Nuclear Information System (INIS)

    Xu Yueping; Zhang Bing; Chen Yang; Zhu Lingqing; Tao Yunliang; Shangguan Zhihong

    2011-01-01

    The discharge of radioactive liquid effluent from inland nuclear power plant under normal operation is an important part to be considered in environmental impact assessment. Requirements of newly revised and upcoming standards GB 6249 and GB 14587 are introduced in this paper. Through an example of an inland NPP siting in the preliminary feasibility study phase, the adaptability to the relevant regulations in the site selection is analyzed. Also, the concerned problems in the design of AP1000 units are addressed. (authors)

  14. Disposal of the radioactive effluents at the 'Commissariat a l'Energie Atomique'. Treatment leading to evacuation into a river

    International Nuclear Information System (INIS)

    Duhamel; Menoux; Candillon

    1958-01-01

    1) The problems dealing with the treatment of the radioactive effluents at the 'Commissariat a l'Energie Atomique' have been studied in order to allow evacuation into a river - after treatment - with respect for the standards regarding radiation protection. 2) At Saclay where there is no possibility of evacuating the effluents, the liquids are directed towards Fontenay-aux-Roses by means of tank wagons. They are removed temporarily into the sewers and will be evacuated later on into the Seine. 3) ln Le Bouchet, the effluents coming from the Factory where urano-thorianite ore is treated will undergo a two stages treatment. The elimination of radium in the first phase facilitates decontamination in the second phase. 4) In Marcoule: a study of synthetic effluents of the Marcoule type is being carried on in order to perfect a selective elimination method of Sr 90 and Cs 137 by coprecipitation. 5) In the general case of the final evacuation into a river, the following problems have been studied: - pre-dilution of treated waters between the storing tanks and the river; - admission in the river; dilution in the river (preliminary study by means of a tracer); - evolution of the activity in the water of the river (adsorption by inert or living elements), contamination of the banks; - locating of the site; - isotopic dilution. 6) Circumstantial study of that last problem. 7) The quantity of a given product in water conditions the isotopic dilution of its radioactive isotopes. When the analysis shows the lack of an element, stable isotopes should be added in order to compensate it. 8) That method led to difficult analysis (specially as far as Sr 90 is concerned), for the percentage of stable isotopes necessary to an important isotopic dilution is very low. 9) The standard regarding the quantity of Sr 90 in drinking water is 8.10 -8 c/m 3 or 4.10 -10 g/m 3 . So a percentage of 40 μg/litre of Sr is enough which is difficult to find out in loaded water, 10) Important elements

  15. Unsupervised Analysis of the Effects of a Wastewater Treatment Plant Effluent on the Fathead Minnow Ovarian Transcriptome

    Science.gov (United States)

    Wastewater treatment plant (WWTP) effluents contain complex mixtures of chemicals, potentially including endocrine active chemicals (EACs), pharmaceuticals, and other contaminants of emerging concern (CECs). Due to the complex and variable nature of effluents, biological monitori...

  16. Determination of 232Th, 230Th and 228Th in liquid effluents from uranium mining

    International Nuclear Information System (INIS)

    Godoy, Jose Marcus de Oliveira

    1979-10-01

    A liquid scintillator αlpha spectrometer was built for the determination of Th- 228 , Th- 230 and Th- 232 in liquid effluents from Uranium mines and mills. The resolution of the αlpha spectrometer was found to be 200-300 KeV, when the scintillator was 8% T0P0, 0,77% scintimix-4 (91% PP0 and 9% Dimetil-P0P0P) and 10% of naphthalene in toluene. Aliquat-336 in xylene (30% v/v) was used to separate the thorium isotopes from other interfering radionuclides (U- 238 , U- 234 , Ra- 226 , Po- 210 ). Under the extraction experimental conditions, the detection limits were 1,2 pCi/1 for Th- 232 , 1,2 pCi/1 for Th- 230 and 0,9 pCi/1 for Th- 228 , for 1000 minutes of counting time. (author)

  17. Radioecological impact of effluents from a nuclear facility being decommissioned in the Antas river hydro graphic basin in the state of Minas Gerais, Brazil. Radioecological impact of effluents in the Antas reservoir

    International Nuclear Information System (INIS)

    Ronque, Leilane Barbosa; Azevedo, Heliana de; Lopes do Nascimento, Marcos Roberto; Roque, Claudio Vitor; Silva, Nivaldo Carlos da; Rodgher, Suzelei; Regali-Seleghim, Mirna Helena

    2008-01-01

    The Antas reservoir receives the treated effluents which come from acid drainage of uranium ore from the UTM-INB (Ore Treatment Unit - Brazilian Nuclear Industries), located in Caldas, Minas Gerais. This study was conducted in order to determine the possible environmental impact caused by discharge of the treated liquid effluent from the UTM into the Antas reservoir. Biological (ciliated protozoa and Peridinium sp. phytoflagellate) and physicochemical variables (manganese, zinc, sulfate, uranium, dissolved oxygen and temperature), trophic state and saprobity indexes were evaluated. Sampling in reservoir (Cab, P41, P14S, and P14F points) took place during the dry winter season (July 2006). Each day, samples were collected four times (6:00 am, 12:00 pm, 6:00 pm, and 12:00 am). Biological variables analyzed at the Antas reservoir classified it as an oligo trophic and beta-mesosaprobic environment. Chemical parameters indicate failures in the nuclear facility effluent treatment plant, showing that effluents outside of standard limits established by Brazilian current legislation for Class II water are being discharged at point P41. These results agree with biological analyses, since point P41 has the lowest diversity and biomass values for ciliated protozoa organisms, indicating possible environmental impacts on the ecosystem due to effluent discharge by this mining company.(author)

  18. Facility effluent monitoring plan for K Area Spent Fuel. Revision 1

    International Nuclear Information System (INIS)

    Hunacek, G.S.

    1995-09-01

    The scope of this document includes program plans for monitoring and characterizing radioactive and nonradioactive hazardous materials discharged in the K Area effluents. This FEMP includes complete documentation for both airborne and liquid effluent monitoring systems that monitor radioactive and nonradioactive hazardous pollutants that could be discharged to the environment under routine and/or upset conditions. This documentation is provided for each K Area facility that uses, generates, releases, or manages significant quantities of radioactive and nonradioactive hazardous materials that could impact public and employee safety and the environment. This FEW describes the airborne and liquid effluent paths and the associated sampling and monitoring systems of the K Area facilities. Sufficient information is provided on the effluent characteristics and the effluent monitoring systems so that a compliance assessment against requirements may be performed. Adequate details are supplied such that radioactive and hazardous material source terms may be related to specific effluent streams which are, in turn, related to discharge points and finally compared to the effluent monitoring system capability

  19. Treatment of industrial effluents in constructed wetlands: challenges, operational strategies and overall performance.

    Science.gov (United States)

    Wu, Shubiao; Wallace, Scott; Brix, Hans; Kuschk, Peter; Kirui, Wesley Kipkemoi; Masi, Fabio; Dong, Renjie

    2015-06-01

    The application of constructed wetlands (CWs) has significantly expanded to treatment of various industrial effluents, but knowledge in this field is still insufficiently summarized. This review is accordingly necessary to better understand this state-of-the-art technology for further design development and new ideas. Full-scale cases of CWs for treating various industrial effluents are summarized, and challenges including high organic loading, salinity, extreme pH, and low biodegradability and color are evaluated. Even horizontal flow CWs are widely used because of their passive operation, tolerance to high organic loading, and decolorization capacity, free water surface flow CWs are effective for treating oil field/refinery and milking parlor/cheese making wastewater for settlement of total suspended solids, oil, and grease. Proper pretreatment, inflow dilutions through re-circulated effluent, pH adjustment, plant selection and intensifications in the wetland bed, such as aeration and bioaugmentation, are recommended according to the specific characteristics of industrial effluents. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Application of inorganic ion exchangers for low and medium activity radioactive effluent decontamination

    International Nuclear Information System (INIS)

    Dozol, J.F.; Eymard, S.; Gambade, R.; La Rosa, G.

    1986-01-01

    This study proposes an alternative pretreatment or treatment for low and medium activity liquid wastes, allowing to improve the quality of containment and decrease the cost of storage. Inorganic ion exchangers are used to remove alpha emitters and long lived fission products and concentrate them in a small volume; these exchangers can be converted into a stable matrix by thermal treatment. This treatment, at least for some liquid wastes, don't exclude a complementary decontamination by chemical precipitation. Sludges, arising from precipitation, exempt from alpha emitters and long lived fission products can be stored in a shallow land burial. This study includes two parts: - Measurements of distribution coefficients for the main nuclides in order to choose, for each liquid wastes, the most suitable ion exchanger. - Estimation of performances of selected inorganic ion exchangers, from tests of percolation of genuine effluents

  1. Liquid radioactive waste processing improvement of PWR nuclear power plants

    International Nuclear Information System (INIS)

    Nery, Renata Wolter dos Reis; Martinez, Aquilino Senra; Monteiro, Jose Luiz Fontes

    2005-01-01

    The study evaluate an inorganic ion exchange to process the low level liquid radwaste of PWR nuclear plants, so that the level of the radioactivity in the effluents and the solid waste produced during the treatment of these liquid radwaste can be reduced. The work compares two types of ion exchange materials, a strong acid cation exchange resin, that is the material typically used to remove radionuclides from PWR nuclear plants wastes, and a mordenite zeolite. These exchange material were used to remove cesium from a synthetic effluent containing only this ion and another effluent containing cesium and cobalt. The breakthrough curves of the zeolite and resin using a fix bed reactor were compared. The results demonstrated that the zeolite is more efficient than the resin in removing cesium from a solution containing cesium and cobalt. The results also showed that a bed combining zeolite and resin can process more volume of an effluent containing cesium and cobalt than a bed resin alone. (author)

  2. Pharmaceutical Formulation Facilities as Sources of Opioids and Other Pharmaceuticals to Wastewater Treatment Plant Effluents

    Science.gov (United States)

    2010-01-01

    Facilities involved in the manufacture of pharmaceutical products are an under-investigated source of pharmaceuticals to the environment. Between 2004 and 2009, 35 to 38 effluent samples were collected from each of three wastewater treatment plants (WWTPs) in New York and analyzed for seven pharmaceuticals including opioids and muscle relaxants. Two WWTPs (NY2 and NY3) receive substantial flows (>20% of plant flow) from pharmaceutical formulation facilities (PFF) and one (NY1) receives no PFF flow. Samples of effluents from 23 WWTPs across the United States were analyzed once for these pharmaceuticals as part of a national survey. Maximum pharmaceutical effluent concentrations for the national survey and NY1 effluent samples were generally effluent had median concentrations ranging from 3.4 to >400 μg/L. Maximum concentrations of oxycodone (1700 μg/L) and metaxalone (3800 μg/L) in samples from NY3 effluent exceeded 1000 μg/L. Three pharmaceuticals (butalbital, carisoprodol, and oxycodone) in samples of NY2 effluent had median concentrations ranging from 2 to 11 μg/L. These findings suggest that current manufacturing practices at these PFFs can result in pharmaceuticals concentrations from 10 to 1000 times higher than those typically found in WWTP effluents. PMID:20521847

  3. Retention soil filter as post-treatment step to remove micropollutants from sewage treatment plant effluent

    NARCIS (Netherlands)

    Brunsch, Andrea F.; Laak, ter Thomas L.; Christoffels, Ekkehard; Rijnaarts, Huub H.M.; Langenhoff, Alette A.M.

    2018-01-01

    Retention soil filters (RSFs) are a specific form of vertical flow constructed wetlands for the treatment of rain water and/or wastewater. We have tested 3 pilot RSFs to investigate removal of dissolved organic carbon (DOC) and 14 different organic micropollutants (OMPs) from the effluent of a

  4. Southeast Regional Wastewater Treatment Plant Facilities Improvements Project and Geysers Effluent Pipeline Project. Draft EIR/EIS: Executive summary

    International Nuclear Information System (INIS)

    1994-01-01

    The Southeast Regional Wastewater Treatment Plant (SERWTP) Facilities Improvement Plan and Geysers Effluent Pipeline and Effluent Injection Project are proposed as a plan to provide expanded wastewater treatment capabilities and to dispose of the effluent by injection in The Geysers geothermal field for purposes of power production. The project is located predominantly in the County of Lake, California, and also in part of Sonoma County. The plan includes various conventional facilities improvements in wastewater treatment to a secondary level of treatment at the SWERWTP. The plan includes facilities to convey the treated effluent in a 26-mile, 24-inch inside diameter pipeline to the Southeast Geysers. The wastewater from the SERWTP would be supplemented by raw lake water diverted from nearby Clear Lake. At The Geysers, the effluent would be directed into a system of distribution lines to wells. In the geothermal reservoir, the water will be converted to steam and collected in production wells that will direct the steam to six existing power plants. This document is a summary of a combined full Environmental Impact Report (EIR) and Environmental Impact Statement (EIS). The EIR/EIS describes the environmental impacts of the various components of the project. Mitigation measures are suggested for reducing impacts to a less than significant level

  5. Environmental risk assessment of effluents as a whole emerging contaminant: Efficiency of alternative tertiary treatments for wastewater depuration.

    Science.gov (United States)

    Díaz-Garduño, B; Pintado-Herrera, M G; Biel-Maeso, M; Rueda-Márquez, J J; Lara-Martín, P A; Perales, J A; Manzano, M A; Garrido-Pérez, C; Martín-Díaz, M L

    2017-08-01

    Emerging contaminants (ECs) and regulated compounds (RCs) from three different WWTP effluents were measured in the current study. The efficiency of two tertiary treatments, Photobiotreatment (PhtBio) and Multi-Barrier Treatment (MBT), for removing contaminants was determined. Results indicated different percentages of removal depending on the treatment and the origin of the effluent. Risk Quotients (RQs) were determined for different species of algae, Daphnia, and fish. RQ results revealed diverse risk values depending on the bioindicator species. Tonalide, galaxolide (fragrances), and ofloxacin (antibiotic) were the most persistent and harmful substances in tested effluents. "Negligible risk" category was reached since a wide diversity of ECs were removed by MBT with high removal percentages. Contrarily, PhtBio was effective only in the depuration of certain chemical compounds, and its efficiency depended on the composition of the raw effluent. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. A guide for preparing Hanford Site facility effluent monitoring plans

    International Nuclear Information System (INIS)

    Nickels, J.M.

    1992-06-01

    This document provides guidance on the format and content of effluent monitoring plans for facilities at the Hanford Site. The guidance provided in this document is designed to ensure compliance with US Department of Energy (DOE) Orders 5400.1 (DOE 1988a), 5400.3 (DOE 1989a), 5400.4 (DOE 1989b), 5400.5 (DOE 1990a), 5480.1 (DOE 1982), 5480.11 (DOE 1988b), and 5484.1 (DOE 1981). These require environmental monitoring plans for each site, facility, or process that uses, generates, releases, or manages significant pollutants of radioactive or hazardous materials. In support of DOE Orders 5400.5 (Radiation Protection of the Public and the Environment) and 5400.1 (General Environmental Protection Program), the DOE Environmental Regulatory Guide for Radiological Effluent Monitoring and Environmental Surveillance (DOE 1991) should be used to establish elements of a radiological effluent monitoring program in the Facility Effluent Monitoring Plan. Evaluation of facilities for compliance with the US Environmental Protection Agency Clean Air Act of 1977 requirements also is included in the airborne emissions section of the Facility Effluent Monitoring Plans. Sampling Analysis Plans for Liquid Effluents, as required by the Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement), also are included in the Facility Effluent Monitoring Plans. The Facility Effluent Monitoring Plans shall include complete documentation of gaseous and liquid effluent sampling and monitoring systems

  7. Assessing the application of advanced oxidation processes, and their combination with biological treatment, to effluents from pulp and paper industry.

    Science.gov (United States)

    Merayo, Noemí; Hermosilla, Daphne; Blanco, Laura; Cortijo, Luis; Blanco, Angeles

    2013-11-15

    The closure of water circuits within pulp and paper mills has resulted in a higher contamination load of the final mill effluent, which must consequently be further treated in many cases to meet the standards imposed by the legislation in force. Different treatment strategies based on advanced oxidation processes (ozonation and TiO2-photocatalysis), and their combination with biological treatment (MBR), are herein assessed for effluents of a recycled paper mill and a kraft pulp mill. Ozone treatment achieved the highest efficiency of all. The consumption of 2.4 g O3 L(-1) resulted in about a 60% COD reduction treating the effluent from the kraft pulp mill at an initial pH=7; although it only reached about a 35% COD removal for the effluent of the recycled paper mill. Otherwise, photocatalysis achieved about a 20-30% reduction of the COD for both type of effluents. In addition, the effluent from the recycled paper mill showed a higher biodegradability, so combinations of these AOPs with biological treatment were tested. As a result, photocatalysis did not report any significant COD reduction improvement whether being performed as pre- or post-treatment of the biological process; whereas the use of ozonation as post-biological treatment enhanced COD removal a further 10%, summing up a total 90% reduction of the COD for the combined treatment, as well as it also supposed an increase of the presence of volatile fatty acids, which might ultimately enable the resultant wastewater to be recirculated back to further biological treatment. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Influent pathogenic bacteria may go straight into effluent in full scale wastewater treatment plants

    DEFF Research Database (Denmark)

    Kristensen, Jannie Munk; Nierychlo, Marta; Albertsen, Mads

    , it is assumed that the bacteria present in the effluent comprise primarily of those bacteria that thrive/grow in the plants. However, standard techniques for detecting bacteria in the effluent, particularly pathogens, are based on culture-dependent methods, which may give erroneous results by underestimating...... flocs. Some of these are known as pathogens. One of these was from the genus Arcobacter (Campylobacteraceae) and it included one particularly abundant OTU found in both influent and effluent in all 14 investigated WWTPs. This single Arcobacter OTU accounted for up to 14% of all bacteria found......Incoming microorganisms to wastewater treatment plants (WWTPs) are usually considered to be adsorbed onto the activated sludge flocs, consumed by protozoan or to just die off. Analyses of the effluent generally show a very high degree of reduction of pathogens supporting this assumption. Thus...

  9. Automatic control of the effluent turbidity from a chemically enhanced primary treatment with microsieving.

    Science.gov (United States)

    Väänänen, J; Memet, S; Günther, T; Lilja, M; Cimbritz, M; la Cour Jansen, J

    2017-10-01

    For chemically enhanced primary treatment (CEPT) with microsieving, a feedback proportional integral controller combined with a feedforward compensator was used in large pilot scale to control effluent water turbidity to desired set points. The effluent water turbidity from the microsieve was maintained at various set points in the range 12-80 NTU basically independent for a number of studied variations in influent flow rate and influent wastewater compositions. Effluent turbidity was highly correlated with effluent chemical oxygen demand (COD). Thus, for CEPT based on microsieving, controlling the removal of COD was possible. Thereby incoming carbon can be optimally distributed between biological nitrogen removal and anaerobic digestion for biogas production. The presented method is based on common automation and control strategies; therefore fine tuning and optimization for specific requirements are simplified compared to model-based dosing control.

  10. A toxicity reduction evaluation for an oily waste treatment plant exhibiting episodic effluent toxicity.

    Science.gov (United States)

    Erten-Unal, M; Gelderloos, A B; Hughes, J S

    1998-07-30

    A Toxicity Reduction Evaluation (TRE) was conducted on the oily wastewater treatment plant (Plant) at a Naval Fuel Depot. The Plant treats ship and ballast wastes, berm water from fuel storage areas and wastes generated in the fuel reclamation plant utilizing physical/chemical treatment processes. In the first period of the project (Period I), the TRE included chemical characterization of the plant wastewaters, monitoring the final effluent for acute toxicity and a thorough evaluation of each treatment process and Plant operating procedures. Toxicity Identification Evaluation (TIE) procedures were performed as part of the overall TRE to characterize and identify possible sources of toxicity. Several difficulties were encountered because the effluent was saline, test organisms were marine species and toxicity was sporadic and unpredictable. The treatability approach utilizing enhancements, improved housekeeping, and operational changes produced substantial reductions in the acute toxicity of the final effluent. In the second period (Period II), additional acute toxicity testing and chemical characterization were performed through the Plant to assess the long-term effects of major unit process improvements for the removal of toxicity. The TIE procedures were also modified for saline wastewaters to focus on suspected class of toxicants such as surfactants. The TRE was successful in reducing acute toxicity of the final effluent through process improvements and operational modifications. The results indicated that the cause of toxicity was most likely due to combination of pollutants (matrix effect) rather than a single pollutant.

  11. Detoxification of kraft pulp ECF bleaching effluents by catalytic hydrotreatment.

    Science.gov (United States)

    Calvo, L; Gilarranz, M A; Casas, J A; Mohedano, A F; Rodríguez, J J

    2007-02-01

    Two different effluents from the D(1) and E(1) stages of the ECF bleaching of Eucalyptus globulus kraft pulp were treated by catalytic hydrogenation in a trickle bed reactor using commercial and homemade Pd/AC catalysts. The reactor was fed with the bleaching effluent and a H(2)/N(2) gas stream. The variables studied were space-time (1.4-5g(cat)min/mL), gas to liquid flow ratio (286-1000vol.), gas feed concentration (H(2):N(2), 1:1-1:7.3vol.), temperature (25-100 degrees C) and pressure (1-11bar). Hydrotreatment performance was evaluated in terms of ecotoxicity, adsorbable organic halogen (AOX), chemical oxygen demand (COD), biological oxygen demand (BOD(5)) and colour removal. In all the runs, the ecotoxicity of the effluents decreased as a result of the treatment, achieving reductions that ranged from 70% to 98%. Simultaneously to the reduction of toxicity, the hydrotreatment led to a decrease of the colour of the effluents, being the decrease significantly higher in the case of E(1) effluent. The AOX content was reduced by 85% and 23% for E(1) and D(1) effluents, respectively. In the case of D(1) effluent the removal of ecotoxicity was significantly higher than that of AOX, which indicates that much of the toxicity of the effluent must be associated to non-chlorinated organics. In spite of the important reduction of ecotoxicity, the biodegradability of the effluents only increased slightly. The homemade catalysts, prepared from activated carbons with a high external or non-microporous surface area and mesopore volume and a convenient surface chemistry showed a higher efficiency than the commercial one.

  12. Treatment of textile effluent in a developed phytoreactor with immobilized bacterial augmentation and subsequent toxicity studies on Etheostoma olmstedi fish

    Energy Technology Data Exchange (ETDEWEB)

    Watharkar, Anuprita D. [Department of Biotechnology, Shivaji University, Kolhapur (India); Khandare, Rahul V. [School of Life Sciences, North Maharashtra University, Jalgaon (India); Waghmare, Pankajkumar R.; Jagadale, Ashwini D.; Govindwar, Sanjay P. [Department of Biochemistry, Shivaji University, Kolhapur (India); Jadhav, Jyoti P., E-mail: jpj_biochem@unishivaji.ac.in [Department of Biotechnology, Shivaji University, Kolhapur (India); Department of Biochemistry, Shivaji University, Kolhapur (India)

    2015-02-11

    Graphical abstract: - Highlights: • A phytoreactor was developed and augmented with immobilized bacteria. • This consortium showed enhanced treatment than the individual species. • Oxido-reductases from P. crinitum and B. pumilus could decolorize the effluent. • Characterization of effluent samples endorsed the efficacy of consortial strategy. • Toxicity studies revealed the less toxic nature of the consortium treated effluent. - Abstract: A static hydroponic bioreactor using nursery grown plants of Pogonatherum crinitum along with immobilized Bacillus pumilus cells was developed for the treatment of textile wastewater. Independent reactors with plants and immobilized cells were also kept for performance and efficacy evaluation. The effluent samples characterized before and after their treatment showed that the plant–bacterial consortium reactor was more efficient than those of individual plant and bacterium reactors. COD, BOD, ADMI, conductivity, turbidity, TDS and TSS of the textile effluent was found to be reduced by 78, 70, 93, 4, 90, 13 and 70% respectively within 12 d by the consortial set. HPTLC analysis revealed the transformation of the textile effluent to new products. The phytotoxicity study on Phaeseolus mungo and Sorghum vulgare seeds showed reduced toxicity of treated effluents. The animal toxicity study performed on Etheostoma olmstedi fishes showed the toxic nature of untreated effluent giving extreme stress to fishes leading to death. Histology of fish gills exposed to treated effluent was found to be less affected. The oxidative stress related enzymes like superoxide dismutase and catalase were found to show decreased activities and less lipid peroxidation in fishes exposed to treated effluent.

  13. Treatment of textile effluent in a developed phytoreactor with immobilized bacterial augmentation and subsequent toxicity studies on Etheostoma olmstedi fish

    International Nuclear Information System (INIS)

    Watharkar, Anuprita D.; Khandare, Rahul V.; Waghmare, Pankajkumar R.; Jagadale, Ashwini D.; Govindwar, Sanjay P.; Jadhav, Jyoti P.

    2015-01-01

    Graphical abstract: - Highlights: • A phytoreactor was developed and augmented with immobilized bacteria. • This consortium showed enhanced treatment than the individual species. • Oxido-reductases from P. crinitum and B. pumilus could decolorize the effluent. • Characterization of effluent samples endorsed the efficacy of consortial strategy. • Toxicity studies revealed the less toxic nature of the consortium treated effluent. - Abstract: A static hydroponic bioreactor using nursery grown plants of Pogonatherum crinitum along with immobilized Bacillus pumilus cells was developed for the treatment of textile wastewater. Independent reactors with plants and immobilized cells were also kept for performance and efficacy evaluation. The effluent samples characterized before and after their treatment showed that the plant–bacterial consortium reactor was more efficient than those of individual plant and bacterium reactors. COD, BOD, ADMI, conductivity, turbidity, TDS and TSS of the textile effluent was found to be reduced by 78, 70, 93, 4, 90, 13 and 70% respectively within 12 d by the consortial set. HPTLC analysis revealed the transformation of the textile effluent to new products. The phytotoxicity study on Phaeseolus mungo and Sorghum vulgare seeds showed reduced toxicity of treated effluents. The animal toxicity study performed on Etheostoma olmstedi fishes showed the toxic nature of untreated effluent giving extreme stress to fishes leading to death. Histology of fish gills exposed to treated effluent was found to be less affected. The oxidative stress related enzymes like superoxide dismutase and catalase were found to show decreased activities and less lipid peroxidation in fishes exposed to treated effluent

  14. Treatment of fast reactor liquid waste- electrochemical method

    International Nuclear Information System (INIS)

    Mahato, Swapan Kumar; Sudha, R.; Anthonysamy, S.; Muralidaran, P.

    2015-01-01

    During the operation of fast reactors, components get wetted by sodium. The sodium wetted primary components such as pumps and intermediate heat exchangers (IHX) in fast reactors are cleaned free of sodium followed by suitable chemical decontamination process before taking them for maintenance or for disposal. This helps in reduction of radiation dose to the operating personnel. Sodium cleaning and decontamination generates large volumes of liquid effluent. The activity in the liquid effluent during sodium cleaning/decontamination is due to 22 Na, 54 Mn, 58 Co, 60 Co, 59 Fe, 137 Cs and 134 Cs. It is required to chemically treat the effluent to reduce the activity levels prior to storage in tanks and transportation to the waste management facility for final disposal. Conventionally the ion exchange method is used for removal of radionuclides which produces large quantities of secondary waste. A method which is suitable both for removal of radionuclides present in low concentration and that avoids generation of large quantities of secondary waste is required. Hence an electrochemical method for metal ion removal is attempted in this work which produces little or no secondary waste. Electrochemical method towards removal of manganese ions was finalized earlier using reticulated vitreous carbon (RVC) from simulated decontamination solution containing a mixture of sulphuric and phosphoric acids. In continuation of the experiments for the removal of cesium ions from simulated cleaning solution which has an alkaline pH, a thin film of nickel hexacyanoferrate (NiHCF) was deposited electrochemically on the surface of RVC. Hexacyanoferrates are known for selectively binding cesium. This NiHCF coated RVC was used for electrodeposition of Cs ions. NiHCF coated and Cs deposited RVC was characterized using SEM/EDX analysis. EDX analysis confirms the presence of Cs on NiHCF coated RVC. (author)

  15. Soil aquifer treatment using advanced primary effluent

    KAUST Repository

    Sharma, Saroj K.; Hussen, Mustefa; Amy, Gary L.

    2011-01-01

    Soil aquifer treatment (SAT) using primary effluent (PE) is an attractive option for wastewater treatment and reuse in many developing countries with no or minimal wastewater treatment. One of the main limitations of SAT of PE is rapid clogging of the infiltration basin due to high suspended solid concentrations. Some pre-treatment of PE before infiltration is likely to reduce this limitation, improve performance of SAT and help to implement this technology effectively. The effects of three pre-treatment options namely sedimentation (SED), coagulation (COAG) and horizontal roughing filtration (HRF) on SAT were analyzed by conducting laboratory-scale batch and soil column experiments. The sedimentation and coagulation pre-treatments led to less head loss development and reduction of clogging effect. The head loss development in soil column using PE + COAG and PE + SED was reduced by 85 and 72%, respectively, compared to PE alone without any pretreatment. The overall dissolved organic carbon (DOC) removal of pre-treatments and soil column collectively were 34, 44, 51 and 43.5% for PE without any pre-treatment, PE + SED, PE+ COAG and PE + HRF, respectively. Coagulation pre-treatment of PE was found to be the most effective option in terms of suspended solids, DOC and nitrogen removal. Sedimentation pre-treatment of PE could be attractive where land is relatively less expensive for the construction of sedimentation basins. © IWA Publishing 2011.

  16. Soil aquifer treatment using advanced primary effluent

    KAUST Repository

    Sharma, Saroj K.

    2011-08-01

    Soil aquifer treatment (SAT) using primary effluent (PE) is an attractive option for wastewater treatment and reuse in many developing countries with no or minimal wastewater treatment. One of the main limitations of SAT of PE is rapid clogging of the infiltration basin due to high suspended solid concentrations. Some pre-treatment of PE before infiltration is likely to reduce this limitation, improve performance of SAT and help to implement this technology effectively. The effects of three pre-treatment options namely sedimentation (SED), coagulation (COAG) and horizontal roughing filtration (HRF) on SAT were analyzed by conducting laboratory-scale batch and soil column experiments. The sedimentation and coagulation pre-treatments led to less head loss development and reduction of clogging effect. The head loss development in soil column using PE + COAG and PE + SED was reduced by 85 and 72%, respectively, compared to PE alone without any pretreatment. The overall dissolved organic carbon (DOC) removal of pre-treatments and soil column collectively were 34, 44, 51 and 43.5% for PE without any pre-treatment, PE + SED, PE+ COAG and PE + HRF, respectively. Coagulation pre-treatment of PE was found to be the most effective option in terms of suspended solids, DOC and nitrogen removal. Sedimentation pre-treatment of PE could be attractive where land is relatively less expensive for the construction of sedimentation basins. © IWA Publishing 2011.

  17. Inorganic ion-exchangers for the treatment and disposal of industrial effluents

    International Nuclear Information System (INIS)

    Hasany, S.M.

    2000-01-01

    Ion-exchangers can be broadly classified into organic and inorganic ion-exchangers. Inorganic ion-exchangers are stable at high temperatures and radiation dosage, resistant towards oxidizing agents and organic solvents. They are cheap and easy to prepare. Inorganic ion-exchangers, due to their superiority over organic ion-exchangers, have been extensively used for a wide variety of applications including treatment and management of industrial effluents. The criteria governing the division into essential and toxic elements for animal life have been described. The occupational sources of toxic elements and their compounds in the environment have been identified and their tolerance limits prescribed in air, water and food are given. The toxicity and adverse effects of harmful elements and their hazardous compounds are mentioned. Factors influencing sorption of trace elements onto inorganic ion-exchangers are highlighted. Examples of inorganic ion-exchangers are cited where they can be utilized for the treatment of industrial effluents before their safe discharge into waterways and biosphere. (author)

  18. Combined methods for liquid radioactive waste treatment. Final report of a co-ordinated research project 1997-2001

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-02-01

    The report contains 13 papers presented at the final research co-ordination meeting of the CRP. The subjects covered include processes and technologies for treatment and conditioning of liquid radioactive wastes. It quite often includes the application of several steps, such as filtration, precipitation, sorption, ion exchange, evaporation and/or membrane separation to meet the requirements both for the release of decontaminated effluents into the environment and the conditioning of waste concentrates for disposal. Combination of the processes and their consecutive or simultaneous application is also described. It results in an improved decontamination, waste volume reduction, safety and overall cost effectiveness in the treatment, conditioning and disposal of these wastes.

  19. Combined methods for liquid radioactive waste treatment. Final report of a co-ordinated research project 1997-2001

    International Nuclear Information System (INIS)

    2003-02-01

    The report contains 13 papers presented at the final research co-ordination meeting of the CRP. The subjects covered include processes and technologies for treatment and conditioning of liquid radioactive wastes. It quite often includes the application of several steps, such as filtration, precipitation, sorption, ion exchange, evaporation and/or membrane separation to meet the requirements both for the release of decontaminated effluents into the environment and the conditioning of waste concentrates for disposal. Combination of the processes and their consecutive or simultaneous application is also described. It results in an improved decontamination, waste volume reduction, safety and overall cost effectiveness in the treatment, conditioning and disposal of these wastes

  20. Possible use of ionic polymers for treatment of radioactive liquid waste

    International Nuclear Information System (INIS)

    Siyam, T.; Nofal, M.; Eldessouky, M.I.; Aly, H.F.

    1992-01-01

    Water-soluble nonionic polymers such as polyacrylamide is recently introduced for treatment of radioactive liquid waste. Eater-soluble ionic polymers such as: poly (sodium acrylate) [anionic polymer], poly (acrylamide-CO-sodium acrylate) [anionic copolymer] and poly (acrylamide-sodium acrylate-diallyldiethylammonium chloride) [amphoteric terpolymer] were prepared by gamma radiation-initiated polymerization of the corresponding monomer solutions. The prepared polymers were assessed for use in treatment of radionuclides that might be present in radioactive waste effluents. It was found that the polymer efficiency for cobalt-60 was affected by the composition of the copolymer and the degree of ionization of the polymer. The efficiency of the polymer increases with increasing the concentration of the polymer. The mechanism of sludge formation for each type of polymer was discussed. It was found that the anionic copolymer is more selective for cobalt than the prepared polymers. Amphoteric terpolymer has different selectivity for cations and anions. 3 figs, 1 tab

  1. Application of advanced oxidation process by electron beam irradiation in the organic compounds degradation present in industrial effluents

    International Nuclear Information System (INIS)

    Duarte, Celina Lopes

    1999-01-01

    The inefficacy of conventional methods to destroy toxic organic compounds present in industrial effluent has taken the search for new technologies of treatment. he water irradiation is the most efficient process to generate radicals that mineralise these compounds. A study to evaluate the Advanced Oxidation Process by electron beam irradiation to treat industrial effluent with high toxic organic compounds concentration was carried out. Experiments were conducted using a Radiation Dynamics Electron Beam Accelerator with 1,5 MeV energy and 37 power. The effluent samples from a big industrial complex were irradiated using the IPEN's Liquid Effluent Irradiation Pilot Plant and the effluent samples from five steps of a Governmental Wastewater Treatment Plant from SABESP - ETE Suzano (industrial Receiver Unit, Coarse Bar Screens, Medium Bar Screens, Primary Sedimentation and Final Effluent), were irradiated in a batch system. The electron beam irradiation showed be efficient on destroying the organic compounds delivered in these effluents mainly chloroform, dichloroethane, methyl isobutyl ketone, benzene, toluene, xylene, phenol and in the decoloring of dyes present in some samples. To remove 90% of the most organic compounds was necessary a 20 kGy dose for industry's ETE, 20 kGy for IRU, CBS and MBS and 10 kGy to 20 kGy for PS and FE. (author)

  2. Investigation of Irrigation Reuse Potential of Wastewater Treatment Effluent from Hamedan Atieh-Sazan General Hospital

    Directory of Open Access Journals (Sweden)

    Mohammad Binavapour

    2007-12-01

    Full Text Available Hospital wastewater is a type of municipal wastewater which may contain pathogenic agents and different microorganisms. If properly treated, the effluent from hospital wastewater treatment facilities can be used for irrigation purposes. To investigate this, the effluent from Hamedan Atieh-Sazan General Hospital was studied. The existing treatment facility uses an extended aeration system with an average wastewater flow rate of approximately 150 m3/day. In addition to evaluating the performance of the wastewater facility at Atieh-Sazan General Hospital, quality parameters of the raw wastewater and the effluent were measured. The mean values obtained for pH, BOD, COD, MPN for total Coliform/100ml, and Nematode/lit in raw wastewater were about 7.1, 238 mg/l, 352 mg/l, 5.5´106, and 2340, respectively. The mean values obtained for pH, BOD, COD, Na%, MPN for total Coliform/100 ml, and Nematode/lit in the effluent were 7.1, 35 mg/L, 77 mg/L, 61, 1561, and 575, respectively. Based on these results, the efficiency of the existing system in removing BOD, COD, and MPN/100 ml were %85.3, %78.3, and %99.97, respectively. With respect to water quality standards available, the quality of the effluent was considered to be suitable for irrigation except for its Na%, MPN for total Coliform, and Nematodes values.

  3. Recycling of dyehouse effluents by biological and chemical treatment

    Energy Technology Data Exchange (ETDEWEB)

    Krull, R.; Doepkens, E. [Inst. of Biochemical Engineering, Technical Univ. of Braunschweig, Braunschweig (Germany)

    2003-07-01

    The introduction of the production integrated environmental protection by closing raw material cycles is shown exemplary for the textile finishing industry. Colored process water with a high content of dissolved organic dyes has always been a non-trivial problem for the sewage engineering sector. The recycling of process water of textile mills is often hindered by remaining color of water-soluable azo dyes after conventional wastewater treatment. Rising costs of emitted wastewater, lawful limits and restricted availability of water makes it of great interest to introduce sophisticated techniques helping to purify dye effluents and to recycle process water. A combined biological and chemical process of purification and recycling of residual dyehouse split flows into the production was developed, investigated and installed by a textile finishing company which produces 330,000 m{sup 3} colored wastewater effluents per year. The process contains anaerobic dye-cleavage, aerobic mineralization of cleavage-products and the decolorization and partial oxidation of traces of dyeresiduals by advanced oxidation. (orig.)

  4. Investigation of endogenous biomass efficiency in the treatment of unhairing effluents from the tanning industry.

    Science.gov (United States)

    Mlaik, Najwa; Bouzid, Jalel; Gharsallah, Neji; Belbahri, Lassad; Woodward, Steve; Mechichi, Tahar

    2009-08-01

    The tanning industry is of great economic importance worldwide; however, the potential environmental impact of tanning is significant. An important component in tanning is the removal of hair from the hide (unhairing), a process which generates considerable amounts of toxic effluent characterized by a high concentration of sulphur, rich mineral compounds, a high alkalinity and a high organic load. The purpose of the work described here was to evaluate the biodegradability of the unhairing wastewater by endogenous biomass in batch culture and continuous systems. The detoxification of the effluent was assessed by seed germination tests. The batch culture experiments showed that variations in COD, temperature and pH significantly affected the endogenous biomass growth and activity. The optimal treatment condition corresponded to an initial COD of 6 g/L, pH of 7 and 30 degrees C. Under continuous culture conditions, the reactor was fed for 48 days with the unhairing effluent. The optimal COD removal efficiency was 85.5%. During treatment, a transformation of sulphides into thiosulphates and then sulphates was also observed. The effect of untreated and treated unhairing wastewater on seed germination of different plant species was studied. The data suggested that treatment decreased the wastewater toxicity. Indeed, germination was inhibited when the effluent dilution was lower than 20% and 10% for treated and untreated wastewater, respectively.

  5. Potential risks of effluent from acid mine drainage treatment plants at abandoned coal mines.

    Science.gov (United States)

    Seo, Jaehwan; Kang, Sung-Wook; Ji, Wonhyun; Jo, Hun-Je; Jung, Jinho

    2012-06-01

    The lethal and sublethal toxicity of effluent from three acid mine drainage treatment plants were monitored from August 2009 to April 2010 using Daphnia magna (reference species) and Moina macrocopa (indigenous species). Acute lethal toxicity was observed in Samma effluent due to incomplete neutralization of acid mine drainages by the successive alkalinity producing system (SAPS). Additionally, there was no significant difference in toxicity values (TU) between D. magna and M. macrocopa (p water bodies.

  6. Optimization of lime treatment processes

    International Nuclear Information System (INIS)

    Zinck, J. M.; Aube, B. C.

    2000-01-01

    Lime neutralization technology used in the treatment of acid mine drainage and other acidic effluents is discussed. Theoretical studies and laboratory experiments designed to optimize the technology of lime neutralization processes and to improve the cost efficiency of the treatment process are described. Effluent quality, slaking temperature, aeration, solid-liquid separation, sludge production and geochemical stability have been studied experimentally and on site. Results show that through minor modification of the treatment process, costs, sludge volume generated, and metal released to the environment can be significantly reduced. 17 refs., 4 figs

  7. Liquid and solid rad waste treatment in advanced nuclear power plants. Application to the SBWR design

    International Nuclear Information System (INIS)

    Tielas Reina, M.; Asuar Alonso, O.

    1994-01-01

    Rad waste treatment requirements for the new generation of American advanced passive and evolutionary power plants are listed in the URD (Utility Requirements Document) of the EPRI (Electrical Power Research Institute). These requirements focus on: - Minimization of shipped solid wastes - Minimization of liquid effluents - Simplification of design and operation, with emphasis not only on waste treatment system design but also on general plant design and operation These objectives are aimed at: - Reducing and segregating wastes at source - Minimizing chemical contamination of these wastes System design simplification is completed by providing free space in the building for the use of mobile plants, either for special services not considered in the basic design or to accommodate future technical advances. (Author)

  8. Treating domestic effluent wastewater treatment by aerobic biofilter with bioballs medium

    Science.gov (United States)

    Permatasari, R.; Rinanti, A.; Ratnaningsih, R.

    2018-01-01

    This laboratory scale research aimed to treat wastewater effluent with advanced treatment utilizing aerobic biofilter with bio-balls medium to obtain effluent quality in accordance with DKI Jakarta Governor Regulation No. 122 of 2005. The seeding and acclimatization were conducted in 4 weeks. The effluent were accommodated in a 150 L water barrel supported by a submersible pump. The effluent were treated in two boxes shaped reactors made of glasses with 36 L of each capacity. These reactors were equipped with aquarium aerators, sampling tap is 10 cm from the base of reactors, and bio-balls with 3 cm diameter are made of PVC. Reactors operated continuously with variations of retention time of 4 hours, 8 hours, 12 hours, 18 hours, and 24 hours and also variations of Carbon: Nitrogen: Phosphor = C: N: P ratio were, 100:5:1, 100:8:1, 100:10:1, 100:12:1, 100:15:1. The results showed that the optimum variance of retention time was 24 hours and the ratio of C:N:P was 100:10:1 yielded the largest removal efficiency for 83,33% of COD, 87,33% of BOD, 82,5% of Ammonia, 79,1% of Nitrate, 92% of Nitrite, 84,82% of Oil and Grease. The concentration parameter resulted from outlet biofilter has met the domestic wastewater quality standard of DKI Jakarta.

  9. Effluent Guidelines

    Science.gov (United States)

    Effluent guidelines are national standards for wastewater discharges to surface waters and municipal sewage treatment plants. We issue the regulations for industrial categories based on the performance of treatment and control technologies.

  10. State waste discharge permit application for the 200 Area Effluent Treatment Facility and the State-Approved Land Disposal Site

    International Nuclear Information System (INIS)

    1993-08-01

    Application is being made for a permit pursuant to Chapter 173--216 of the Washington Administrative Code (WAC), to discharge treated waste water and cooling tower blowdown from the 200 Area Effluent Treatment Facility (ETF) to land at the State-Approved Land Disposal Site (SALDS). The ETF is located in the 200 East Area and the SALDS is located north of the 200 West Area. The ETF is an industrial waste water treatment plant that will initially receive waste water from the following two sources, both located in the 200 Area on the Hanford Site: (1) the Liquid Effluent Retention Facility (LERF) and (2) the 242-A Evaporator. The waste water discharged from these two facilities is process condensate (PC), a by-product of the concentration of waste from DSTs that is performed in the 242-A Evaporator. Because the ETF is designed as a flexible treatment system, other aqueous waste streams generated at the Hanford Site may be considered for treatment at the ETF. The origin of the waste currently contained in the DSTs is explained in Section 2.0. An overview of the concentration of these waste in the 242-A Evaporator is provided in Section 3.0. Section 4.0 describes the LERF, a storage facility for process condensate. Attachment A responds to Section B of the permit application and provides an overview of the processes that generated the wastes, storage of the wastes in double-shell tanks (DST), preliminary treatment in the 242-A Evaporator, and storage at the LERF. Attachment B addresses waste water treatment at the ETF (under construction) and the addition of cooling tower blowdown to the treated waste water prior to disposal at SALDS. Attachment C describes treated waste water disposal at the proposed SALDS

  11. Review of Potential Candidate Stabilization Technologies for Liquid and Solid Secondary Waste Streams

    Energy Technology Data Exchange (ETDEWEB)

    Pierce, Eric M.; Mattigod, Shas V.; Westsik, Joseph H.; Serne, R. Jeffrey; Icenhower, Jonathan P.; Scheele, Randall D.; Um, Wooyong; Qafoku, Nikolla

    2010-01-30

    Pacific Northwest National Laboratory has initiated a waste form testing program to support the long-term durability evaluation of a waste form for secondary wastes generated from the treatment and immobilization of Hanford radioactive tank wastes. The purpose of the work discussed in this report is to identify candidate stabilization technologies and getters that have the potential to successfully treat the secondary waste stream liquid effluent, mainly from off-gas scrubbers and spent solids, produced by the Hanford Tank Waste Treatment and Immobilization Plant (WTP). Down-selection to the most promising stabilization processes/waste forms is needed to support the design of a solidification treatment unit (STU) to be added to the Effluent Treatment Facility (ETF). To support key decision processes, an initial screening of the secondary liquid waste forms must be completed by February 2010.

  12. Detection of glucocorticoid receptor agonists in effluents from sewage treatment plants in Japan.

    Science.gov (United States)

    Suzuki, Go; Sato, Kentaro; Isobe, Tomohiko; Takigami, Hidetaka; Brouwer, Abraham; Nakayama, Kei

    2015-09-15

    Glucocorticoids (GCs) are widely used as anti-inflammatory drugs. Our previous study demonstrated that several GCs such as cortisol and dexamethasone (Dex) were frequently detected in effluents collected from Japanese sewage treatment plants (STPs) in 2012. In this study, we used the GC-Responsive Chemical-Activated LUciferase gene eXpression (GR-CALUX) assay to elucidate GC receptor (GR) agonistic activities of ten pure synthetic GCs and selected STP effluents in Japan for assessment of the risks associated with the presence of GR agonists. The tested GCs demonstrated dose-dependent agonistic effects in the GR-CALUX assay and their EC50 values were calculated for estimation of relative potencies (REPs) compared to Dex. The GR agonistic potency was in the rank of: clobetasol propionate > clobetasone butyrate > betamethasone 17-valerate > difluprednate > betamethasone 17,21-dipropionate > Dex > betamethasone > 6α-methylprednisolone > prednisolone > cortisol. The GR agonistic activity in STP effluents as measured in Dex-equivalent (Dex-EQ) activities ranged from effluents in Japan. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Liquid waste treatment system. Final report

    International Nuclear Information System (INIS)

    Baker, M.N.; Houston, H.M.

    1999-01-01

    Pretreatment of high-level liquid radioactive waste (HLW) at the West Valley Demonstration Project (WVDP) involved three distinct processing operations: decontamination of liquid HLW in the Supernatant Treatment System (STS); volume reduction of decontaminated liquid in the Liquid Waste Treatment System (LWTS); and encapsulation of resulting concentrates into an approved cement waste form in the Cement Solidification System (CSS). Together, these systems and operations made up the Integrated Radwaste Treatment System (IRTS)

  14. Removal of pollutants from pulp and paper mill effluent by anaerobic and aerobic treatment in pilot scale bioreactor

    DEFF Research Database (Denmark)

    Singh, P.; Katiyar, D.; Gupta, M.

    2011-01-01

    Pilot-scale anaerobic and aerobic treatment in a two-step bioreactor was performed for the removal of pollutants from pulp and paper mill effluent. After seven days of anaerobic treatment, colour (45%), lignin (60%), COD (26%) and adsorbable organic halogen (AOX) (20%) were reduced. The anaerobic......Pilot-scale anaerobic and aerobic treatment in a two-step bioreactor was performed for the removal of pollutants from pulp and paper mill effluent. After seven days of anaerobic treatment, colour (45%), lignin (60%), COD (26%) and adsorbable organic halogen (AOX) (20%) were reduced....... The anaerobically treated effluent was then treated in a bioreactor in the presence of a fungal strain (Aspergillus fumigatus) or a bacterial strain (Pseudomonas ovalis). The results of this study indicated a reduction in colour (76% and 56%), lignin (78% and 68%), COD (85% and 78%) and AOX (70% and 82...

  15. Studies on uranium recovery from inlet stream of Effluent Treatment Plant by novel 'In-House' sorbent

    International Nuclear Information System (INIS)

    Sangita Pal; Tewari, P.K.; Suchismita Mishra; Pandit, G.G.; Puranik, V.D.; Satpati, S.K.

    2011-01-01

    'In-House' resin Polyacrylhydroxamic acid (PHOA) has been synthesized and utilized targeting ground water remediation; recovery of uranium from low concentration aqueous solution e.g., mining activities related water, flooding of excavated or deplumed areas, nuclear plant washed effluent and process generated effluents in nuclear plant during front-end as well as back-end treatment. In the present study, treatment of field effluent containing heavy metals and radio-nuclides from contaminated mining sites reflected preference for uranium with respect to manganese. The specific complexation between the extractant and metal ion especially uranium provides high distribution co-efficient (K d ) for uranium (K d,U = 1,450 mL/g from inlet of Effluent Treatment Plant (ETP) and K d,U = 74,950 mL/g for synthetic solution) compared to high level impurity (1,000 times higher concentration) of manganese (K d,Mn = 111 mL/g from inlet of ETP and K d,Mn = 10,588 mL/g for synthetic solution). The 'In-House' resin showed significant extractability (70-95% elution efficiency) and indicates a possibility of selective removal/recovery of the valuable metal ions even from secondary sources. As a specialty, resin can be regenerated and reused. (author)

  16. Facility effluent monitoring plan for the 300 Area Fuels Fabrication Facility

    International Nuclear Information System (INIS)

    Nickels, J.M.; Brendel, D.F.

    1991-11-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP- 0438. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan is the first annual report. It shall ensure long-range integrity of the effluent monitoring system by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated as a minimum every three years. The Fuel Fabrication Facility in the Hanford 300 Area supported the production reactors from the 1940's until they were shut down in 1987. Prior to 1987 the Fuel Fabrication Facility released both airborne and liquid radioactive effluents. In January 1987 the emission of airborne radioactive effluents ceased with the shutdown of the fuels facility. The release of liquid radioactive effluents have continued although decreasing significantly from 1987 to 1990

  17. Radioactive liquid effluent management - state of art and the role of membrane processes

    International Nuclear Information System (INIS)

    Panicker, S.T.; Prabhakar, S.; Misra, B.M.; Ramani, M.P.S.

    1990-01-01

    This report reviews the conventional methods involving filtration, chemical precipitation, evaporation and ion exchange, employed for the treatment of low level radioactive effluents. The role of membrane processes, particularly reverse osmosis and ultrafiltration has been assessed with a view to increase the effectiveness of the existing methods. After overviewing the practices followed in major countries, a possible scheme has been proposed. (author). 66 refs., 4 tabs., figs

  18. Acute lethality data for Ontario's electric power generation sector effluents covering the period from December 1990 to May 1991

    International Nuclear Information System (INIS)

    Poirier, D.G.; Lee, J.T.; Mueller, M.C.; Westlake, G.F.

    1995-01-01

    Regulations require that electric power generation facilities monitor their liquid effluents. Acute lethality tests are simple, rapid standard methods for measuring potential impacts on aquatic ecosystems. These toxicity tests will detect harmful concentrations of chemicals and mixtures of compounds in effluents, but compliance with end of pipe limits for acute toxicity will not necessarily control all adverse environmental effects. In these tests, aquatic organisms were exposed to undiluted effluent, as well as a series of effluent dilutions for a fixed period of time. This report is a compilation of six months of test results. Typically the most toxic samples were taken from the waste treatment plant (WTP) neutral sumps. This was true for fossil fueled as well as for nuclear generating stations. tabs., figs

  19. Radiological assessment and management of radioactive spill in a liquid waste treatment facility - Case study

    International Nuclear Information System (INIS)

    Amer, H.A.; Shawky, S.; Ibrahiem, N.

    2002-01-01

    The radiological assessment and management of radioactive spill from liquid waste treatment facility is presented. The incident contaminated the area surrounding the treatment facility with various radionuclides, which were dispersed into the soil. A method based on the European basic safety standards was used to contain the risks associated with the contaminated site. The introduced case study proceeded up to the stage of simplified risk study, since the site is small and it was relatively easy to remove and store the contaminated soil. According to the obtained results, the removal of the upper 30-cm would be considered as appropriate remedying action to resume background level. One of the most important basic concepts of radiation protection in nuclear facilities is the continuity of monitoring radiological release to the environment. It is known that from nuclear facilities only very small amounts of radioactivity are discharged with the liquid effluents and the exhaust air into the environment. Recent studies screening the natural and artificial radionuclide in soil samples from the investigated area revealed normal background concentrations with no anomalies

  20. Alternatives to disposal of Hanford Site liquid effluents to the soil column

    International Nuclear Information System (INIS)

    Meinhardt, C.C.; Flyckt, D.L.; Wirsing, R.M.; Winterhalder, J.A.

    1987-04-01

    Alternative systems were selected for 28 effluent streams, based on the use of available technology and ability to eliminate the contaminated effluent or reduce contaminant levels to meet specified effluent disposal criteria and standards derived from DOE Orders and environmental statutes. This study determined that technically feasible alternative waste disposal systems are available. 6 refs., 2 figs., 2 tabs

  1. Effluent Information System (EIS) / Onsite Discharge Information System (ODIS): 1986 executive summary

    International Nuclear Information System (INIS)

    Watanabe, T.

    1987-09-01

    Department of Energy (DOE) data base systems aid DOE-Headquarters and Field Offices in managing the radioactive air and liquid effluents from DOE facilities. Data on effluents released offsite are entered into effluent information system (EIS) and data on effluents discharged onsite and retained onsite are entered into Onsite Discharge Information System (ODIS). This document is a summary of information obtained from the CY 1986 effluent data received from all DOE and DOE contractor facilities and entered in the data bases. Data from previous years are also included. The summary consists of information for effluents released offsite, and information for effluents retained onsite

  2. Treatment of the Bleaching Effluent from Sulfite Pulp Production by Ceramic Membrane Filtration

    Directory of Open Access Journals (Sweden)

    Mehrdad Ebrahimi

    2015-12-01

    Full Text Available Pulp and paper waste water is one of the major sources of industrial water pollution. This study tested the suitability of ceramic tubular membrane technology as an alternative to conventional waste water treatment in the pulp and paper industry. In this context, in series batch and semi-batch membrane processes comprising microfiltration, ultrafiltration and nanofiltration, ceramic membranes were developed to reduce the chemical oxygen demand (COD and remove residual lignin from the effluent flow during sulfite pulp production. A comparison of the ceramic membranes in terms of separation efficiency and performance revealed that the two-stage process configuration with microfiltration followed by ultrafiltration was most suitable for the efficient treatment of the alkaline bleaching effluent tested herein, reducing the COD concentration and residual lignin levels by more than 35% and 70%, respectively.

  3. Treatment of the Bleaching Effluent from Sulfite Pulp Production by Ceramic Membrane Filtration.

    Science.gov (United States)

    Ebrahimi, Mehrdad; Busse, Nadine; Kerker, Steffen; Schmitz, Oliver; Hilpert, Markus; Czermak, Peter

    2015-12-31

    Pulp and paper waste water is one of the major sources of industrial water pollution. This study tested the suitability of ceramic tubular membrane technology as an alternative to conventional waste water treatment in the pulp and paper industry. In this context, in series batch and semi-batch membrane processes comprising microfiltration, ultrafiltration and nanofiltration, ceramic membranes were developed to reduce the chemical oxygen demand (COD) and remove residual lignin from the effluent flow during sulfite pulp production. A comparison of the ceramic membranes in terms of separation efficiency and performance revealed that the two-stage process configuration with microfiltration followed by ultrafiltration was most suitable for the efficient treatment of the alkaline bleaching effluent tested herein, reducing the COD concentration and residual lignin levels by more than 35% and 70%, respectively.

  4. Cross-flow filtration with different ceramic membranes for polishing wastewater treatment plant effluent

    DEFF Research Database (Denmark)

    Farsi, Ali; Hammer Jensen, Sofie; Roslev, Peter

    Nowadays the need for sustainable water treatment is essential because water shortages are increasing. Depending on the wastewater treatment plant (WWTP) effluent constituents, the effluent cannot be simply discharged to environment because it contains toxic ions and organic micropollutants which...... pore size is 15 nm), mesoporous γ-alumina (5 nm), microporous TiO2 (1nm) and microporous hybrid silica (used. The total ions and specified toxic ions (e. g. Cu2+) rejections were measured using conductivity measurements and atomic adsorption...... spectroscopy, respectively. The type and the molecular size of removed organic compounds were determined using pH, full spectrum UV and size exclusion HPLC. Inorganic N-compound rejections were calculated by N-autoanalyzer. The retention of humic like substances measured by UV254 (Fig.1) decreased almost...

  5. Biogas Production Using Anaerobic Biodigester from Cassava Starch Effluent

    Directory of Open Access Journals (Sweden)

    S. Sunarso

    2010-12-01

    Full Text Available IKMs’ factory activity in Margoyoso produces liquid and solid wastes. The possible alternative was to use the liquid effluent as biogas raw material. This study focuses on the used of urea, ruminant, yeast, microalgae, the treatment of gelled and ungelled feed for biogas production, pH control during biogas production using buffer Na2CO3, and feeding management in the semi-continuous process of biogas production that perform at ambient temperature for 30 days. Ruminant bacteria, yeast, urea, and microalgae was added 10% (v/v, 0.08% (w/v, 0.04% (w/v, 50% (v/v of mixing solution volume, respectively. The pH of slurry was adjusted with range 6.8-7.2 and was measured daily and corrected when necessary with Na2CO3. The total biogas production was measured daily by the water displacement technique. Biogas production from the ungelling and gelling mixture of cassava starch effluent, yeast, ruminant bacteria, and urea were 726.43 ml/g total solid and 198 ml/g total solid. Biogas production from ungelling mixture without yeast was 58.6 ml/g total solid. Biogas production from ungelling mixture added by microalgae without yeast was 58.72 ml/g total solid and that with yeast was 189 ml/g total solid. Biogas production from ungelling mixture of cassava starch effluent, yeast, ruminant bacteria, and urea in semi-continuous process was 581.15 ml/g total solid. Adding of microalgae as nitrogen source did not give significant effect to biogas production. But adding of yeast as substrate activator was very helpful to accelerate biogas production. The biogas production increased after cassava starch effluent and yeast was added. Requirement of sodium carbonate (Na2CO3 to increase alkalinity or buffering capacity of fermenting solution depends on pH-value

  6. Genotoxicity of swine effluents.

    Science.gov (United States)

    Techio, V H; Stolberg, J; Kunz, A; Zanin, E; Perdomo, C C

    2011-01-01

    This study aimed at the investigation of genotoxic effects of swine effluents from different stages of a treatment system for swine wastes through bioassay of stamen hairs and micronuclei in Tradescantia (clone BNL 4430). No significant differences (p≥0.05) regarding the genic mutations were found in the bioassay of stamen hairs, independently of the effluent analysed. For the genotoxicity test with micronuclei, the plants exposed to raw wastes, to sludge, and to effluent of the biodigester have presented higher rates of chromosomal damages (micronuclei), with significant differences in relation to the control group and other effluent of the waste treatment system (p≤0.05). The association between the chemical parameters and the genotoxicity data have shown that the variables COD and TKN have presented significant correlation (p≤0.05) with the number of mutagenic events in the tetrads.

  7. Development of a surfactant liquid membrane extraction process for the cleansing of industrial aqueous effluents containing metallic cation traces

    International Nuclear Information System (INIS)

    Rapaumbya Akaye, Guy-Roland

    1994-01-01

    The purpose of this work was to develop a process of surfactant liquid membrane extraction to purify industrial waste solution containing Cu(II), Fe(III), and Zn(II) (about 0,1 g/L). The extractant is the ammonium salt of Cyanex 306 and Aliquat 336. The first part of this work deals with the study of the liquid-liquid extraction of the metals. The efficiency of the extractant has been shown for the extraction of each metal alone and for Cu(II) and Zn(II) in the case of a mixture of the three metals. During this study we have observed that Fe(III) is reduced to Fe(II) (which is not extracted by the salt of Cyanex 301) in presence of Cu(II) and the quaternary ammonium salt (Aliquat 336). The optimisation of the experimental conditions for the discontinuous surfactant liquid membrane process led us to choose the following composition of the emulsion: 1,5 % of Cyanex 301 salt, 2,5 % of ECA 4360, dodecan. The internal phase is an aqueous solution containing 3,5 mol/L of NaOH and 0,5 mol/L tri-ethanolamin The residual concentration of Cu(II) and Zn(II) in the external phase is very low. In the case of iron, only 60 % are extracted because of the reduction phenomenon (10 % in liquid-liquid extraction). The realisation of the continuous process in pulsed column, after optimisation of hydrodynamics conditions, leads to similar results. In stationary conditions, we obtain a raffinate containing less than 0,5 mg/L of Cu(II) and Zn(II) and 36 mg/L of iron. The internal phase contains about 2 g/L of Cu(II) an Zn(II). We tried and minimize the reduction of Fe(III) in surfactant liquid membrane process. Less than 16 % of iron cannot be reduced. This leads to a purification of only 84 % In the basis of these results, processes of purification have been proposed for effluents of various composition. They enable to purify the effluent and besides to concentrate the pollutants about twenty times. (author) [fr

  8. Algal-based immobilization process to treat the effluent from a secondary wastewater treatment plant (WWTP)

    International Nuclear Information System (INIS)

    He Shengbing; Xue Gang

    2010-01-01

    Algal-based immobilization process was applied to treat the effluent from a secondary wastewater treatment plant. Batch test proved that algae could attach onto fiber-bundle carrier in 7 days, and then the algal-based immobilization reactor could reduce TN (total nitrogen) and TP (total phosphorus) significantly within 48 h. Based on the above investigations, the hydraulic retention time (HRT) of the algal-based immobilization reactor in continuous operation mode was determined to be 2 days. During the 91 days of experiment on the treating secondary effluent of Guang-Rao wastewater treatment plant, it was found that the fiber-bundle carrier could collect the heterobacteria and nitrifying bacteria gradually, and thus improved the COD removal efficiency and nitrification performance step by step. Results of the continuous operation indicated that the final effluent could meet the Chinese National First A-level Sewage Discharge Standard when the algal-based immobilization reactor reached steady state.

  9. Assessment of Nelumbo nucifera and Hydrilla verticillata in the treatment of pharmaceutical industry effluent from 24 Parganas, West Bengal

    Directory of Open Access Journals (Sweden)

    Shamba Chatterjee

    2014-10-01

    Full Text Available Modern day technologies employed in industrialization and unhygienic lifestyle of mankind has led to a severe environmental menace resulting in pollution of freshwater bodies. Pharmaceutical industry effluents cause eutrophication and provide adequate nutrients for growth of pathogenic bacteria. This study has been conducted with aquatic plants water lotus (Nelumbo nucifera and hydrilla (Hydrilla verticillata with an novel aim to treat pharmaceutical industry effluents showing the outcome of the experiments carried out with the effluents collected from rural areas of 24 Parganas, West Bengal, India. Determination of pH, solid suspend, BOD5, NH3-N, MPN and coliform test were used for this notioned purpose. Pharmaceutical waste effluent water treated with water lotus showed less pH, solid suspend, DO, BOD, NH3-N, MPN and coliform bacteria than hydrilla treatment when compared to the control. In conclusion, water lotus is found to be more efficient in treatment of pharmaceutical industry effluent waste water than hydrilla.

  10. Advanced biological treatment of aqueous effluent from the nuclear fuel cycle

    International Nuclear Information System (INIS)

    Pitt, W.W. Jr.; Hancher, C.W.; Patton, B.D.; Shumate, S.E. II.

    1979-01-01

    Many of the processing steps in the nuclear fuel cycle generate aqueous effluent streams bearing contaminants that can, because of their chemical or radiological properties, pose an environmental hazard. Concentration of such contaminants must be reduced to acceptable levels before the streams can be discharged to the environment. Two classes of contaminants, nitrates and heavy metals, are addressed in this study. Specific techniques aimed at the removal of nitrates and radioactive heavy metals by biological processes are being developed, tested, and demonstrated. Although cost comparisons between biological processes and current treatment methods are presented, these comparisons may be misleading because biological processes yield environmentally better end results which are difficult to price. However, a strong case is made for the use of biological processes for removing nitrates and heavy metals fron nuclear fuel cycle effluents. The estimated costs for these methods are as low as, or lower than, those for alternate processes. In addition, the resulting disposal products - nitrogen gas, CO 2 , and heavy metals incorporated into microorganisms - are much more ecologically desirable than the end products of other waste treatment methods

  11. Development of a liquid filter testing technique using radioisotope

    International Nuclear Information System (INIS)

    Kumar, Surender; Ramarathinam, K.; Khan, A.A.

    1979-01-01

    Efficient removal of suspended matter from liquids was always in demand in industries as a process requirement for the recovery of suspended materials. In nuclear industry the filters are required to remove fine suspended matter from water in reactors, effluent treatment plants, fuel reprocessing plants etc. The filters are used to maintain clarity and to limit the activity level to a minimum. In effluent treatment plants low level liquid waste is discharged to the environment after removing active suspended matter by filters. Various type of liquid filters are available in the market to meet the demands of different industries. These filters must be evaluated for their removal effectiveness for particulate matter from liquids. The filters are evaluated using several techniques like gravimetric analysis, turbidity measurement, direct counting of particles using optical and electronic instruments etc. All the techniques have their own advantages and disadvantages. Counting of radioactive particles using radiation counters is a simple and sensitive technique. It involves the neutron activation of selected test powders which are dispersed in the liquid and led through the test filter; the up-stream and down-stream concentrations are measured using GM counter. This technique was found to be consistent and reproducible in the low, middle and high ranges of efficiency. Selection of a test powder, its activation and use for evaluating liquid filters are dealt with. (auth.)

  12. Automated system of control of radioactive liquid effluents of patients submitted to therapy in hospitals of nuclear medicine (SACEL); Sistema automatizado de control de efluentes liquidos radiactivos de pacientes sometidos a terapia en hospitales de medicina nuclear (SACEL)

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz C, M A; Rivero G, T; Celis del Angel, L; Sainz M, E; Molina, G [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2006-07-01

    Different hospitals of nuclear medicine require of the technical attendance for the design, construction and instrumentation of an effluents retention system coming from the room dedicated to the medical application of iodine 131, with the one object of giving execution to the normative requirements of radiological protection, settled down in the General Regulation of Radiological Safety (RGSR) emitted by the CNSNS in November, 1988 and in the corresponding official standards. An automatic system of flow measurement, the activity concentration of the effluents to the drainage, the discharges control and the automated report it will allow the execution of the national regulations, also the elimination of unhealthy activities as the taking of samples, analysis of those same and the corresponding paperwork, its will allow that the SACEL is capable of to carry out registrations that are to consult in an automated way. The changes in the demands of the National Commission of Nuclear Safety and Safeguards in relation to the liberation of radioactive material in hospitals by medical treatments, it has created the necessity to develop a system that quantifies and dose the liquid effluents of people under thyroid treatment with iodine-131 to the drainage. The Automated System of Control of radioactive liquids effluents generated in Hospitals of Nuclear Medicine (SACEL) developed in the National Institute of Nuclear Research, it fulfills this regulation, besides improving the work conditions for the medical and technical personnel of the hospital in that are installed, since this system has the advantage of to be totally automated and to require of a minimum of attendance. The SACEL is an electro-hydraulic system of effluents control, based in the alternate operation of two decay deposits of the activity of the material contaminated with iodine-131. The system allows to take a registration of those volumes and liberated dose, besides being able to be monitoring in remote

  13. Coagulant recovery from water treatment plant sludge and reuse in post-treatment of UASB reactor effluent treating municipal wastewater.

    Science.gov (United States)

    Nair, Abhilash T; Ahammed, M Mansoor

    2014-09-01

    In the present study, feasibility of recovering the coagulant from water treatment plant sludge with sulphuric acid and reusing it in post-treatment of upflow anaerobic sludge blanket (UASB) reactor effluent treating municipal wastewater were studied. The optimum conditions for coagulant recovery from water treatment plant sludge were investigated using response surface methodology (RSM). Sludge obtained from plants that use polyaluminium chloride (PACl) and alum coagulant was utilised for the study. Effect of three variables, pH, solid content and mixing time was studied using a Box-Behnken statistical experimental design. RSM model was developed based on the experimental aluminium recovery, and the response plots were developed. Results of the study showed significant effects of all the three variables and their interactions in the recovery process. The optimum aluminium recovery of 73.26 and 62.73 % from PACl sludge and alum sludge, respectively, was obtained at pH of 2.0, solid content of 0.5 % and mixing time of 30 min. The recovered coagulant solution had elevated concentrations of certain metals and chemical oxygen demand (COD) which raised concern about its reuse potential in water treatment. Hence, the coagulant recovered from PACl sludge was reused as coagulant for post-treatment of UASB reactor effluent treating municipal wastewater. The recovered coagulant gave 71 % COD, 80 % turbidity, 89 % phosphate, 77 % suspended solids and 99.5 % total coliform removal at 25 mg Al/L. Fresh PACl also gave similar performance but at higher dose of 40 mg Al/L. The results suggest that coagulant can be recovered from water treatment plant sludge and can be used to treat UASB reactor effluent treating municipal wastewater which can reduce the consumption of fresh coagulant in wastewater treatment.

  14. Aerobic effluent treatment with lower electric power consumption. Survey of results from questionnaire sent out to Swedish pulp and paper mills with biological effluent treatment plants; Aerob rening med laegre elfoerbrukning. Sammanstaellning av enkaetsvar fraan svenska skogsindustrier med biologisk rening

    Energy Technology Data Exchange (ETDEWEB)

    Sivard, Aasa; Simon, Olle

    2010-12-15

    A survey of the energy situation at 23 Swedish pulp and paper mills with aerobic effluent treatment plants has been performed. The electricity consumption for aeration equipment is about 80 % of the total electricity consumption. Proposed measures to increase energy efficiency are regular measurements of energy consumption, better control of the oxygen level in some mills and evaluation of measures to use the heat in process effluent before and after biological treatment

  15. Safety evaluation for packaging transport of LSA-II liquids in MC-312 cargo tanks

    Energy Technology Data Exchange (ETDEWEB)

    Carlstrom, R.F.

    1996-09-11

    This safety evaluation for packaging authorizes the onsite transfer of bulk LSA-II radioactive liquids in the 222-S Laboratory Cargo Tank and Liquid Effluent Treatment Facility Cargo Tanks (which are U.S. Department of Transportation MC-312 specification cargo tanks) from their operating facilities to tank farm facilities.

  16. Method for removing and decolorizing aqueous waste effluents containing dissolved or dispersed organic matter

    International Nuclear Information System (INIS)

    Case, F.N.; Ketchen, E.E.

    1975-01-01

    A method is provided for treating organic waste material dissolved or dispersed in an aqueous effluent, which comprises contacting the effluent with an inert particulate carbonaceous sorbent at an oxygen pressure up to 2000 psi, irradiating the resultant mixture with high energy radiation until a decolorized liquid is produced, and then separating the decolorized liquid

  17. Sizewell nuclear power station: investigation of radiation exposure pathways from liquid effluents. Local habits survey 1981

    International Nuclear Information System (INIS)

    Leonard, D.R.P.; Smith, B.D.

    1982-01-01

    A habits and consumption survey to review radiation exposure pathways due to liquid effluents released from the CEGB Sizewell site is described. It is relevant to both the Sizewell A and proposed Sizewell B nuclear power stations. The main objectives are to provide input data to a radiological assessment by means of identifying critical groups and to provide data for guidance in a review of environmental monitoring programmes. The way in which data for the different pathways should be combined in order to aid the subsequent radiological assessment is discussed. Recommendations are made for adjustments to the present monitoring programmes. (U.K.)

  18. Soil Aquifer Treatment : Assessment and Applicability of Primary Effluent Reuse in Developing Countries

    NARCIS (Netherlands)

    Abel, C.D.T.

    2014-01-01

    This thesis showed that soil aquifer treatment (SAT) is an effective polishing technology for reuse of primary effluent. The study experimentally revealed relatively high removal of suspended solids, bulk organic matter, nutrients, pharmaceutically active compounds and pathogens indicators under

  19. Soil Aquifer Treatment: Assessment and Applicability of Primary Effluent Reuse in Developing Countries

    NARCIS (Netherlands)

    Abel, C.D.T.

    2014-01-01

    This thesis showed that soil aquifer treatment (SAT) is an effective polishing technology for reuse of primary effluent. The study experimentally revealed relatively high removal of suspended solids, bulk organic matter, nutrients, pharmaceutically active compounds and pathogens indicators under

  20. Treatment of radioactive effluents at the Boris Kidric Institute; Postupak sa radioaktivnim elementima u Institutu Boris Kidric

    Energy Technology Data Exchange (ETDEWEB)

    Bojovic, P; Drobnik, S; Popara, D [Institute of Nuclear Sciences Vinca, Beograd (Serbia and Montenegro)

    1964-10-15

    The paper describes the origin, composition and activity of radioactive effluents at the Boris Kidric Institute, their collection at the places or origin, transport to the place of disposal and treatment of some smaller quantities. Special attention has been paid to effluents with short-lived isotopes produced in the Laboratory for radioactive isotope production (author)

  1. Waste treatment at the La Hague and Marcoule sites

    International Nuclear Information System (INIS)

    1995-04-01

    In this report, an overview of waste treatment and solidification facilities located at the La Hague and Marcoule sites, which are owned and/or operated by Cogema, provided. The La Hague facilities described in this report include the following: The STE3 liquid effluent treatment facility (in operation); the AD2 solid waste processing facility (also in operation); and the UCD alpha waste treatment facility (under construction). The Marcoule facilities described in this report, both of which are in operation, include the following: The STEL-EVA liquid effluent treatment facilities for the entire site; and the alpha waste incinerator of the UPI plant. This report is organized into four sections: this introduction, low-level waste treatment at La Hague, low-level waste treatment at Marcoule, and new process development. including the solvent pyrolysis process currently in the development stage for Cogema's plants

  2. Waste treatment at the La Hague and Marcoule sites

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-04-01

    In this report, an overview of waste treatment and solidification facilities located at the La Hague and Marcoule sites, which are owned and/or operated by Cogema, provided. The La Hague facilities described in this report include the following: The STE3 liquid effluent treatment facility (in operation); the AD2 solid waste processing facility (also in operation); and the UCD alpha waste treatment facility (under construction). The Marcoule facilities described in this report, both of which are in operation, include the following: The STEL-EVA liquid effluent treatment facilities for the entire site; and the alpha waste incinerator of the UPI plant. This report is organized into four sections: this introduction, low-level waste treatment at La Hague, low-level waste treatment at Marcoule, and new process development. including the solvent pyrolysis process currently in the development stage for Cogema`s plants.

  3. Cryo magnetic separation adaptation to environment technologies: application to industrial effluents; Adaptation de la separation cryomagnetique aux technologies de l`environnement: application a l`epuration d`effluents liquides industriels

    Energy Technology Data Exchange (ETDEWEB)

    Bureau, V

    1993-12-20

    Cryomagnetic separation adaptation to environment technologies application to industrial liquid effluents. The performance, obtained by superconducting high filed - high gradient magnetic separation, permitted to foresee the magnetic treatment of heavy metals in rinse waters, derived from the surface finishing industry. The paramagnetic ions, precipitated in basic media as hydroxides, present a very hydrated amorphous structure, which masks their subjacent magnetic properties. Coprecipitation of a `magnetic carrier`, jointly with the heavy metals, has been studied: ferric chloride forms in basic media, an hydrated iron oxide. Its structure is of the goethite type, and it stabilizes as hematite. The magnetic susceptibility of the obtained product is still weak and its crystalline structure is not enough affirmative to utilize magnetic filtration with efficiency. Mixture of ferrous sulphate and ferric chloride forms, in a basic media, an hydrated magnetite. Initial ideal ratio between divalent iron and trivalent iron, varies between 0,5 and 1,2. This mixture, coprecipitated with the heavy metals, permits to optimize the magnetic cleaning of the fluids in a high field - high gradient filter. (author)

  4. Coal washery effluent treatment for material recovery and water reuse

    Energy Technology Data Exchange (ETDEWEB)

    Banerjee, N.N.; Chaudhuri, M.

    1980-10-01

    Th effluent from coal washeries consisting mainly of coal fines is normally discharged to inland surface waters and causes severe river pollution with substantial loss of good quality coking coal. The study reported in this paper was undertaken to characterize the effluents from several coal washeries and to evaluate the potential of using various coagulants and coagulant aids for clarification of the effluent with a view to recovery of the coal fines and reuse of the clarified effluent. It has been demonstrated that higher recovery of coal fines can be achieved by using coagulants like alum or ferric chloride with or without coagulant aids with an added advantage of reuse of the clarified effluent in the washery.

  5. Readiness Assessment Plan, Hanford 200 areas treated effluent disposal facilities

    International Nuclear Information System (INIS)

    Ulmer, F.J.

    1995-01-01

    This Readiness Assessment Plan documents Liquid Effluent Facilities review process used to establish the scope of review, documentation requirements, performance assessment, and plant readiness to begin operation of the Treated Effluent Disposal system in accordance with DOE-RLID-5480.31, Startup and Restart of Facilities Operational Readiness Review and Readiness Assessments

  6. Modified natural zeolite as heterogeneous Fenton catalyst in treatment of recalcitrants in industrial effluent

    Directory of Open Access Journals (Sweden)

    Milton M. Arimi

    2017-04-01

    Full Text Available Industrial effluents with high recalcitrants should undergo post-treatment after biological treatment. The aim of this study was to use cheap and abundantly available natural materials to develop heterogeneous Fenton catalysts for the removal of colored recalcitrants in molasses distillery wastewater (MDW. The pellets of zeolite, which is naturally available in many countries, were modified by pre-treatment with sulphuric acid, nitric acid and hydrochloric acid, before embedding on them the ferrous ions. The effects of pH and temperature on heterogeneous Fenton were studied using the modified catalysts. The sulphuric acid-ferrous modified catalysts showed the highest affectivity which achieved 90% color and 60% TOC (total organic carbon removal at 150 g/L pellet catalyst dosage, 2 g/L H2O2 and 25 °C. The heterogeneous Fenton with the same catalyst caused improvement in the biodegradability of anaerobic effluent from 0.07 to 0.55. The catalyst was also applied to pre-treat the raw MDW and increased it's biodegradability by 4%. The color of the resultant anaerobic effluent was also reduced. The kinetics of total TOC removal was found to depend on operation temperature. It was best described by simultaneous first and second order kinetics model for the initial reaction and second order model for the rest of the reaction.

  7. Safety evaluation for packaging (Onsite) transport of LSA-II liquids in MC-312 cargo tanks

    International Nuclear Information System (INIS)

    Carlstrom, R.F.

    1996-01-01

    This safety evaluation for packaging authorizes the onsite transfer of bulk LSA-II radioactive liquids in the 222-S Laboratory Cargo Tank and Liquid Effluent Treatment Facility Cargo Tanks (which are U.S. Department of Transportation MC-312 specification cargo tanks) from their operating facilities to tank farm facilities

  8. The determination of Pu-241 by liquid scintillation counting in gaseous effluents of an incineration facility, FERAB, and the Karlsruhe Nuclear Reprocessing Plant, WAK

    International Nuclear Information System (INIS)

    Godoy, J.M.; Schuettelkopf, H.

    1983-03-01

    Although the concentration of Pu-241 in nuclear fuel to be reprocessed is high, there are only few results published about the emission of Pu-241 with gaseous and liquid effluents. Nearly no information is available, too, about the environmental contamination of nuclear installations by Pu-241. Therefore a procedure was developed to measure Pu-241 by liquid scintillation counting. Sample preparation was performed by electroplating of plutonium on stainless steel planchets. To correct the selfabsorption the linear dependence of counting efficiency in the liquid scintillation counter and the resolution in the α-spectrometer was used. (orig./HP) [de

  9. Treatment of textile effluent by chemical (Fenton's Reagent) and biological (sequencing batch reactor) oxidation

    International Nuclear Information System (INIS)

    Rodrigues, Carmen S.D.; Madeira, Luis M.; Boaventura, Rui A.R.

    2009-01-01

    The removal of organic compounds and colour from a synthetic effluent simulating a cotton dyeing wastewater was evaluated by using a combined process of Fenton's Reagent oxidation and biological degradation in a sequencing batch reactor (SBR). The experimental design methodology was first applied to the chemical oxidation process in order to determine the values of temperature, ferrous ion concentration and hydrogen peroxide concentration that maximize dissolved organic carbon (DOC) and colour removals and increase the effluent's biodegradability. Additional studies on the biological oxidation (SBR) of the raw and previously submitted to Fenton's oxidation effluent had been performed during 15 cycles (i.e., up to steady-state conditions), each one with the duration of 11.5 h; Fenton's oxidation was performed either in conditions that maximize the colour removal or the increase in the biodegradability. The obtained results allowed concluding that the combination of the two treatment processes provides much better removals of DOC, BOD 5 and colour than the biological or chemical treatment alone. Moreover, the removal of organic matter in the integrated process is particularly effective when Fenton's pre-oxidation is carried out under conditions that promote the maximum increase in wastewater biodegradability.

  10. Fate of wastewater effluent hER-agonists and hER-antagonists during soil aquifer treatment.

    Science.gov (United States)

    Otakuye, Conroy; Quanrud, David M; Ela, Wendell P; Wicke, Daniel; Lansey, Kevin E; Arnold, Robert G

    2005-04-01

    Estrogen activity was measured in wastewater effluent before and after polishing via soil-aquifer treatment (SAT) using both a (hER-beta) competitive binding assay and a transcriptional activation (yeast estrogen screen, YES) assay. From the competitive binding assay, the equivalent 17alpha-ethinylestradiol (EE2) concentration in secondary effluent was 4.7 nM but decreased to 0.22 nM following SAT. The YES assay indicated that the equivalent EE2 concentration in the same effluent sample was below the method-detection limit (bioassays alone should not be relied upon to measure estrogenic activity in complex environmental samples because the simultaneous presence of both agonists and antagonist compounds can yield false negatives. Multiple in vitro bioassays, sample fractionation or tests designed to measure anti-estrogenic activity can be used to overcome this problem. It is also clear that there are circumstances under which SAT does not completely remove estrogenic activity during municipal wastewater effluent polishing.

  11. Efficiency of combined process of ozone and bio-filtration in the treatment of secondary effluent.

    Science.gov (United States)

    Tripathi, Smriti; Tripathi, B D

    2011-07-01

    The present work was aimed at studying the efficiency of the combined process of biofiltration with ozonation to improve the quality of secondary effluent. The secondary effluent from the Dinapur Sewage Treatment Plant Varanasi, India was used in this work. The process of biofiltration with the plant species of Eichornia crassipes and Lemna minor, at a flow rate of 262 ml min(-1) and plant density of 30 mg L(-1) for 48 h, in combination with the process of ozonation with ozone dose of 10 mg L(-1) and contact time of 5 min was applied. Results revealed that combined process was statistically most suitable for the highest degradation of physico-chemical and microbial parameters with improving BDOC value. The biofiltration process is able to remove highest percentage of toxic heavy metals from the secondary effluent without production of toxicity. This technique is highly recommendable for tropical wastewater where sewage is mixed with industrial effluents. Copyright © 2011 Elsevier Ltd. All rights reserved.

  12. Wastewater treatment plant effluent as a source of microplastics: review of the fate, chemical interactions and potential risks to aquatic organisms.

    Science.gov (United States)

    Ziajahromi, Shima; Neale, Peta A; Leusch, Frederic D L

    2016-11-01

    Wastewater treatment plant (WWTP) effluent has been identified as a potential source of microplastics in the aquatic environment. Microplastics have recently been detected in wastewater effluent in Western Europe, Russia and the USA. As there are only a handful of studies on microplastics in wastewater, it is difficult to accurately determine the contribution of wastewater effluent as a source of microplastics. However, even the small amounts of microplastics detected in wastewater effluent may be a remarkable source given the large volumes of wastewater treatment effluent discharged to the aquatic environment annually. Further, there is strong evidence that microplastics can interact with wastewater-associated contaminants, which has the potential to transport chemicals to aquatic organisms after exposure to contaminated microplastics. In this review we apply lessons learned from the literature on microplastics in the aquatic environment and knowledge on current wastewater treatment technologies, with the aim of identifying the research gaps in terms of (i) the fate of microplastics in WWTPs, (ii) the potential interaction of wastewater-based microplastics with trace organic contaminants and metals, and (iii) the risk for aquatic organisms.

  13. New treatment facility for low level process effluents at the Savannah River site

    International Nuclear Information System (INIS)

    Ebra, M.A.; Bibler, J.P.; Johnston, B.S.; Kilpatrick, L.L.; Poy, F.L.; Wallace, R.M.

    1987-01-01

    A new facility, the F/H Effluent Treatment Facility (F/H ETF) is under construction at the Savannah River site. It will decontaminate process effluents containing low levels of radionuclides and hazardous chemicals prior to discharge to a surface stream. These effluents, which are currently discharged to seepage basins, originate in the chemical separations and high-level radioactive waste processing areas, known as F-Area and H-Area. The new facility will allow closure of the basins in order to meet the provisions of the Resource Conservation and Recovery Act by November 1988. A high degree of reliability is expected from this design as a result of extensive process development work that has been conducted at the Savannah River Laboratory. This work has included both bench scale testing of individual unit operations and pilot scale testing of an integrated facility, 150 to 285 L/min (40 to 75 gpm), that contains the major operations

  14. Facility effluent monitoring plan for the 327 Facility

    International Nuclear Information System (INIS)

    1994-11-01

    The 327 Facility [Post-Irradiation Testing Laboratory] provides office and laboratory space for Pacific Northwest Laboratory (PNL) scientific and engineering staff conducting multidisciplinary research in the areas of post-irradiated fuels and structural materials. The facility is designed to accommodate the use of radioactive and hazardous materials in the conduct of these activities. This report summarizes the airborne emissions and liquid effluents and the results of the Facility Effluent Monitoring Plan (FEMP) determination for the facility. The complete monitoring plan includes characterization of effluent streams, monitoring/sampling design criteria, a description of the monitoring systems and sample analysis, and quality assurance requirements

  15. Low cost methods of treatment of agricultural effluents in warm climates

    Energy Technology Data Exchange (ETDEWEB)

    Parker, C.D.

    Treatment of effluents by anaerobic-aerobic lagoons, flood and spray irrigation and grass filtration is outlined and there are 4 examples of plants disposing respectively of waste from a domestic population with a cannery, vegetable and milk processing plants and a slaughterhouse; 2 wineries and a brandy distillery; a milk processing plant; and a potato processing plant. In the 3rd example high-strength dairy factory effluent (12,000 mg BOD/1) is fermented to methane and CO/sub 2/ with a daily yield of 59,000 cubic feet gas from 35,000 gal of waste; the outflow from fermenters and low strength waste (2500 mg BOD/1) is treated in a lagoon which removes greater than 90% BOD and passes to an oxidation ditch before irrigating pasture. A cost comparison of the various systems is included.

  16. A note on the utilisation of the water hyacinth (eichhornia crassipes) for the treatment of tannery effluents

    International Nuclear Information System (INIS)

    1981-01-01

    Water hyacinth is an aquatic weed which grows quickly in ponds, ditches and streams. It clogs drains, irrigation canals and run-off streams promoting back waters and flood conditions. By its prolific growth it competes with other aquatic weeds and causes destruction of the ecosystems of inland waters. Other damaging effects of water hyacinth include incubation of insects and disease vectors, hindrance to navigation, interference with fishing, increased loss of water by plant transpiration, restriction of desirable aquatic plant growth, depletion of oxygen in water and destruction of recreation values of inland waters. It has been observed from the literature that world-wide attempts have been made to destroy water hyacinth for the reasons enumerated above. But recently emphasis has been given to its utilisation rather than its destruction. Reports are available on its use in paper and pulp industries, for production of biogas, as a food for animals and as fertilizer. Water hyacinth has been used in oxidation ponds for the treatment of digested sugar wastes and effluents of septic tanks, but no work has been reported as yet on use of water hyacinth in the treatment of tannery effluents. The waste water from a tannery is highly coloured with a foul odour and contains toxic materials like phenols, sulphides and chromium in addition to bio-degradable matter like proteins, flesh, hair, etc. The untreated effluents when let into streams deplete the dissolved oxygen of the stream and destroy the aquatic life. Similarly, when the untreated effluents are let off into sewers they choke the sewers, or when let off on land they cause ground water pollution. The conventional methods of treatment of sewage, namely the trickling filter activated sludge process are equally applicable for the treatment of tannery waste water. But these methods are known to be costly both in construction and maintenance. Certain low-cost waste treatment methods have been developed involving the use

  17. Design improvement and performance evaluation of solar photocatalytic reactor for industrial effluent treatment.

    Science.gov (United States)

    Nair, Ranjith G; Bharadwaj, P J; Samdarshi, S K

    2016-12-01

    This work reports the details of the design components and materials used in a linear compound parabolic trough reactor constructed with an aim to use the photocatalyst for solar photocatalytic applications. A compound parabolic trough reactor has been designed and engineered to exploit both UV and visible part of the solar irradiation. The developed compound parabolic trough reactor could receive almost 88% of UV radiation along with a major part of visible radiation. The performance of the reactor has been evaluated in terms of degradation of a probe pollutant using the parameters such as rate constant, residence time and photonic efficiency. An attempt has been made to assess the performance in different ranges of solar spectrum. Finally the developed reactor has been employed for the photocatalytic treatment of a paper mill effluent using Degussa P25 as the photocatalyst. The paper mill effluent collected from Nagaon paper mill, Assam, India has been treated under both batch mode and continuous mode using Degussa P25 photocatalyst under artificial and natural solar radiation, respectively. The photocatalytic degradation kinetics of the paper mill effluent has been determined using the reduction in total organic carbon (TOC) values of the effluent. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Facility Effluent Monitoring Plan for the 325 Radiochemical Processing Laboratory

    International Nuclear Information System (INIS)

    Shields, K.D.; Ballinger, M.Y.

    1999-03-01

    This Facility Effluent Monitoring Plan (FEMP) has been prepared for the 325 Building Radiochemical Processing Laboratory (RPL) at the Pacific Northwest National Laboratory (PNNL) to meet the requirements in DOE Order 5400.1, ''General Environmental Protection Programs.'' This FEMP has been prepared for the RPL primarily because it has a ''major'' (potential to emit >0.1 mrem/yr) emission point for radionuclide air emissions according to the annual National Emission Standards for Hazardous Air Pollutants (NESHAP) assessment performed. This section summarizes the airborne and liquid effluents and the inventory based NESHAP assessment for the facility. The complete monitoring plan includes characterization of effluent streams, monitoring/sampling design criteria, a description of the monitoring systems and sample analysis, and quality assurance requirements. The RPL at PNNL houses radiochemistry research, radioanalytical service, radiochemical process development, and hazardous and radioactive mixed waste treatment activities. The laboratories and specialized facilities enable work ranging from that with nonradioactive materials to work with picogram to kilogram quantities of fissionable materials and up to megacurie quantities of other radionuclides. The special facilities within the building include two shielded hot-cell areas that provide for process development or analytical chemistry work with highly radioactive materials and a waste treatment facility for processing hazardous, mixed radioactive, low-level radioactive, and transuranic wastes generated by PNNL activities

  19. Facility Effluent Monitoring Plan for the 325 Radiochemical Processing Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Shields, K.D.; Ballinger, M.Y.

    1999-04-02

    This Facility Effluent Monitoring Plan (FEMP) has been prepared for the 325 Building Radiochemical Processing Laboratory (RPL) at the Pacific Northwest National Laboratory (PNNL) to meet the requirements in DOE Order 5400.1, ''General Environmental Protection Programs.'' This FEMP has been prepared for the RPL primarily because it has a ''major'' (potential to emit >0.1 mrem/yr) emission point for radionuclide air emissions according to the annual National Emission Standards for Hazardous Air Pollutants (NESHAP) assessment performed. This section summarizes the airborne and liquid effluents and the inventory based NESHAP assessment for the facility. The complete monitoring plan includes characterization of effluent streams, monitoring/sampling design criteria, a description of the monitoring systems and sample analysis, and quality assurance requirements. The RPL at PNNL houses radiochemistry research, radioanalytical service, radiochemical process development, and hazardous and radioactive mixed waste treatment activities. The laboratories and specialized facilities enable work ranging from that with nonradioactive materials to work with picogram to kilogram quantities of fissionable materials and up to megacurie quantities of other radionuclides. The special facilities within the building include two shielded hot-cell areas that provide for process development or analytical chemistry work with highly radioactive materials and a waste treatment facility for processing hazardous, mixed radioactive, low-level radioactive, and transuranic wastes generated by PNNL activities.

  20. Assessing Methanobrevibacter smithii and Clostridium difficile as not conventional faecal indicators in effluents of a wastewater treatment plant integrated with sludge anaerobic digestion.

    Science.gov (United States)

    Romanazzi, Valeria; Bonetta, Silvia; Fornasero, Stefania; De Ceglia, Margherita; Gilli, Giorgio; Traversi, Deborah

    2016-12-15

    Wastewater treatment plants (WWTP) are an important source of surface water contamination by enteric pathogens, affecting the role of environmental water as a microbial reservoir. We describe the release to the environment of certain anaerobes of human and environmental concern. The work was focused on emerging microbial targets. They are tracing, by RT-qPCR, on WWTP effluents, both liquid and solid, when an anaerobic digestion step is included. The focus is placed on Clostridium spp. with the specific quantification of Clostridium perfringens, as typical bioindicator, and Clostridium difficile, as emerging pathogen not only confined into nosocomial infection. Moreover methanogens were quantified for their involvement in the anaerobic digestion, and in particular on Methanobrevibacter smithii as major methanogenic component of the human gut microbiome and as not conventional faecal indicator. In the water samples, a reduction, statistically significant, in all microbial targets was observed (p effluents, particularly bio-solids, to reduce the potential release of pathogens into the environment. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Testing for Nuclear Thermal Propulsion Systems: Identification of Technologies for Effluent Treatment in Test Facilities

    Data.gov (United States)

    National Aeronautics and Space Administration — Key steps to ensure identification of relevant effluent treatment technologies for Nuclear Thermal Propulsion (NTP) testing include the following. 1. Review of...

  2. Stress-related gene expression changes in rainbow trout hepatocytes exposed to various municipal wastewater treatment influents and effluents.

    Science.gov (United States)

    Gagné, F; Smyth, S A; André, C; Douville, M; Gélinas, M; Barclay, K

    2013-03-01

    The present study sought to examine the performance of six different wastewater treatment processes from 12 wastewater treatment plants using a toxicogenomic approach in rainbow trout hepatocytes. Freshly prepared rainbow trout hepatocytes were exposed to increasing concentrations of influent (untreated wastewaters) and effluent (C(18)) extracts for 48 h at 15 °C. A test battery of eight genes was selected to track changes in xenobiotic biotransformation, estrogenicity, heavy metal detoxification, and oxidative stress. The wastewaters were processed by six different treatment systems: facultative and aerated lagoons, activated sludge, biological aerated filter, biological nutrient removal, chemically assisted primary treated, and trickling filter/solids contact. Based on the chemical characteristics of the effluents, the treatment plants were generally effective in removing total suspended solids and chemical oxygen demand, but less so for ammonia and alkalinity. The 12 influents differed markedly with each other, which makes the comparison among treatment processes difficult. For the influents, both population size and flow rate influenced the increase in the following mRNA levels in exposed hepatocytes: metallothionein (MT), cytochrome P4503A4 (CYP3A4), and vitellogenin (VTG). Gene expression of glutathione S-transferase (GST) and the estrogen receptor (ER), were influenced only by population size in exposed cells to the influent extracts. The remaining genes-superoxide dismutase (SOD) and multidrug resistance transporter (MDR)-were not influenced by either population size or flow rate in exposed cells. It is noteworthy that the changes in MT, ER, and VTG in cells exposed to the effluents were significantly affected by the influents across the 12 cities examined. However, SOD, CYP1A1, CYP3A4, GST, and MDR gene expression were the least influenced by the incoming influents. The data also suggest that wastewater treatments involving biological or aeration

  3. Characterization of effluent from food processing industries and stillage treatment trial with Eichhornia crassipes (Mart. and Panicum maximum (Jacq.

    Directory of Open Access Journals (Sweden)

    N.A. Noukeu

    2016-12-01

    Full Text Available In this study, effluents from 11 food processing industries from various sectors were characterized through analysis of physical and chemical parameters. In general, effluents pHs are between 4.07 and 7.63. Lead (Pb2+ and cadmium (Cd+ concentrations range from 0.083 to 1.025 mg/l and 0.052–0.158 mg/l respectively. The biodegradability of the effluent is very low. The principal component analysis (PCA grouped industries according to their organic matter levels; thus, stillage, livestock, molasses and sugar refinery effluents show some similarities, as well as confectionery, oil mill, dairy and brewery effluents. Forms of nitrogen measured show low levels of nitrites (NO2−, high levels of nitrates (NO3−, ammonium (NH4+ and Kjeldahl nitrogen (TKN. Among these effluents, a treatment trial with Eichhornia crassipes and Panicum maximum was applied to stillage effluent from Fermencam distillery. The results show that Panicum maximum and Eichhornia crassipes reduce pollutant loads of Fermencam's wastewater.

  4. Study of technical and economical feasibility for implementation of a movable unit for treatment of industrial effluents with electron beam; Estudo de viabilidade tecnica e economica para implementacao de uma unidade movel para tratamento de efluentes industriais com feixe de eletrons

    Energy Technology Data Exchange (ETDEWEB)

    Rela, Carolina Sciamarelli

    2006-07-01

    The treatment of industrial effluents is a practice that is disseminating in accelerated rhythm, of contributing to reinforce the public image, through the combat of the pollution, it brings economical advantages allowing the companies the reuse of the treated water in their own processes. The liquid effluent treatment technique studied in the present work is the one that uses the chemical oxidation/reduction standing out the use of the electron beam (e.b.) radiation. This technique uses an advanced oxidation process, generating radicals highly reagents that provoke the oxidation, reduction, dissociation and degradation in composed organic and exercising lethal effect in general in the microorganisms and parasites. In this work a conceptual and basic project of a movable unit of effluents treatment using electron beam radiation process was developed, in order that the unit moves until the treatment point, where the effluent is produced, facilitating the logistics. A technical and economical feasibility study was also elaborated allowing data on the capacity and cost of effluents processing to consolidate the values of the necessary investments to be presented to foundations organs for the construction of a movable unit. The results of the studies demonstrated that it is technically viable attending the pertinent legislation of Brazil, in the aspects of Radiation Protection and transport limit capacity. The unitary cost of the e.b. radiation processing in the movable unit was shown more expensive than in the fixed unit, the reason is the decrease of the efficiency of the interaction of the incident electrons in the effluent, due to the reduction of electron energy operation time of the unit. (author)

  5. Evaluation of waste stabilization ponds effluent efficiency on the growth and nutritive characteristics of cluster beans (cyamopsis tetragonoloba l.) taub

    International Nuclear Information System (INIS)

    Khan, M.; Shaukat, S.S.; Alamgir, A.; Hasan, S.A.

    2014-01-01

    South Asian countries including Pakistan are facing chronic shortage of water supply which is anticipated to be aggravated in future. These countries are agribased where the continued water supply is crucial for sustainable economy. One of the possible alternatives to overcome the problems of water scarcity is the used of treated wastewater which is gaining much importance even in the western world. The treated wastewater can be used as a liquid fertilizer which could provide dual benefits both in terms of saving of fresh water as well as inorganic fertilizers. The potential of treated effluent from waste stabilization ponds (WSP) and equivalent basal fertilizer on growth and nutritive quality of cluster beans (Cyamopsis tetragonoloba L.) Taub. was investigated under field conditions. Treated effluent significantly increased fresh weight of leaves and stems. Dry weight of stem was also significantly higher with the treatment of WSP effluent as compared to the use of basal fertilizer and fresh water. Fresh and dry fruit weights, number of seeds per fruit and fruit length were also significantly increased in WSP effluent treatment as compared to other two treatments. Treatment with WSP effluent also improved the nutritive characteristics such as crude proteins and total carbohydrates. However, total fat and ash content percentage of Cyamopsis tetragonoloba remained unaltered. The application of WSP effluent also increased NPK and organic matter content of the soil after harvesting the crop which would be helpful for succeeding crop. The study demonstrated that treated effluent can be successfully used for unrestricted irrigation in the water deficient areas of Pakistan thereby saving huge quantities of fresh water. (author)

  6. A history of effluent releases from the Texas A and M University reactor

    Energy Technology Data Exchange (ETDEWEB)

    Bates, E F; Neff, R D; Sandel, P S; Schoenbucher, B [Texas A and M University (United States)

    1974-07-01

    Since 1966 records of radioactive effluents releases from the Texas A and M University Research Reactor have been compiled. These data include particulate activity, noble gases, and liquid effluent releases. Particulate activity releases with half-lives greater than eight days were negligible and are not included in this presentation. Conversion from an MTR plate reactor to a TRIGA fueled reactor was completed in August 1968. Records of effluent releases of Argon-4l and liquids for the past, five years are summarized, in this presentation. These release data are compared to the current limits specified: in 10 CPR 20 and the limits appearing in proposed Appendix.

  7. Conventional methods and emerging wastewater polishing technologies for palm oil mill effluent treatment: a review.

    Science.gov (United States)

    Liew, Wai Loan; Kassim, Mohd Azraai; Muda, Khalida; Loh, Soh Kheang; Affam, Augustine Chioma

    2015-02-01

    The Malaysian palm oil industry is a major revenue earner and the country is ranked as one of the largest producers in the world. However, growth of the industry is synonymous with a massive production of agro-industrial wastewater. As an environmental protection and public health concern, the highly polluting palm oil mill effluent (POME) has become a major attention-grabber. Hence, the industry is targeting for POME pollution abatement in order to promote a greener image of palm oil and to achieve sustainability. At present, most palm oil mills have adopted the ponding system for treatment. Due to the successful POME pollution abatement experiences, Malaysia is currently planning to revise the effluent quality standards towards a more stringent discharge limits. Hence, the current trend of POME research focuses on developing tertiary treatment or polishing systems for better effluent management. Biotechnologically-advanced POME tertiary (polishing) technologies as well as other physicochemical methods are gaining much attention as these processes are the key players to push the industry towards the goal of environmental sustainability. There are still ongoing treatment technologies being researched and the outcomes maybe available in a while. However, the research completed so far are compiled herein and reported for the first time to acquire a better perspective and insight on the subject with a view of meeting the new standards. To this end, the most feasible technology could be the combination of advanced biological processes (bioreactor systems) with extended aeration, followed by solids separation prior to discharge. Chemical dosing is favoured only if effluent of higher quality is anticipated. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Treatment of secondary effluent by sequential combination of photocatalytic oxidation with ceramic membrane filtration.

    Science.gov (United States)

    Song, Lili; Zhu, Bo; Jegatheesan, Veeriah; Gray, Stephen; Duke, Mikel; Muthukumaran, Shobha

    2018-02-01

    The aim of the present work was to experimentally evaluate an alternative advanced wastewater treatment system, which combines the action of photocatalytic oxidation with ceramic membrane filtration. Experiments were carried out using laboratory scale TiO 2 /UV photocatalytic reactor and tubular ceramic microfiltration (CMF) system to treat the secondary effluent (SE). A 100-nm pore size CMF membrane was investigated in cross flow mode under constant transmembrane pressure of 20 kPa. The results show that specific flux decline of CMF membrane with and without TiO 2 /UV photocatalytic treatment was 30 and 50%, respectively, after 60 min of filtration. Data evaluation revealed that the adsorption of organic compounds onto the TiO 2 particles was dependent on the pH of the suspension and was considerably higher at low pH. The liquid chromatography-organic carbon detector (LC-OCD) technique was used to characterise the dissolved organic matter (DOM) present in the SE and was monitored following photocatalysis and CMF. The results showed that there was no removal of biopolymers and slight removal of humics, building blocks and the other oxidation by-products after TiO 2 /UV photocatalytic treatment. This result suggested that the various ions present in the SE act as scavengers, which considerably decrease the efficiency of the photocatalytic oxidation reactions. On the other hand, the CMF was effective for removing 50% of biopolymers with no further removal of other organic components after photocatalytic treatment. Thus, the quantity of biopolymers in SE has an apparent correlation with the filterability of water samples in CMF.

  9. Reduction of releases of radioactive effluents from light-water-power-reactors in Japan

    International Nuclear Information System (INIS)

    Yoshida, Y.; Itakura, T.; Kanai, T.

    1977-01-01

    Japan Atomic Energy Commission established the dose objectives to the population around the light-water-reactors in May, 1975, based on the ''ALAP'' concept. These values are respectively, 5 mrems per year for total body and 15 mrems per year for thyroid of an individual in the critical group in the environs, due to both gaseous and liquid effluents from LWRs in one site. The present paper describes the implications of the dose objective values, control measures which have been adopted to reduce releases of radioactive materials and related technical developments in Japan. The main control measures for reduction of radioactive gaseous effluents are an installation of a charcoal gas holdup system for decay of noble gases and a supply of clean steam for the gland seal of a turbine in BWR, and a storage tank system allowing decay of noble gases in PWR. For liquid effluents are taken measures to re-use them as the primary coolant. Consequently, the amounts of radioactivity released to the environment from any LWR during normal operation have been maintained under the level to meet the above dose objective values. For research reactors, reduction of release of effluents has also been carried out in a similar way to LWRs. In order to establish the techniques applicable for further reduction, studies are being made on the control measures to reduce leakage of radioiodine, an apparatus for removal of krypton, the treatment of laundry waste and measures to remove the crud in the primary coolant. Presentation is also made on the energy-integrated gas monitor for gaseous effluent and systems of measuring γ dose from radioactive cloud descriminating from natural background, which have been developed for effective monitoring thus reduced environmental dose

  10. Variations in nitrate isotope composition of wastewater effluents by treatment type in Hong Kong.

    Science.gov (United States)

    Archana, A; Li, Luo; Shuh-Ji, Kao; Thibodeau, Benoit; Baker, David M

    2016-10-15

    Stable isotopes (δ(15)N, δ(18)O) can serve as tracers for sources of nitrogen in the receiving environment. Hong Kong discharges ~3×10(6)m(3)d(-1) of treated wastewater into the ocean from 68 facilities implementing preliminary to tertiary treatment. We sampled treated sewage from 18 plants across 5 treatment types and examined receiving seawater from northeast Hong Kong. We analyzed nitrate and nitrite (NO3(-)+NO2(-), hereafter NOx) ammonium (NH4(+)), phosphate (PO4(+)) concentrations and δ(15)NNOx, δ(18)ONOx. Sewage effluents contained high mean nutrient concentrations (NO3(-)=260μmolL(-1), NH4(+)=1400μmolL(-1), PO4(+)=50μmolL(-1)) with some indication of nitrogen removal in advanced treatment types. Mean δ(15)NNOx of sewage effluents from all plants and treatment types (12‰) was higher than natural sources and varied spatially and seasonally. There was no overall effect of sewage treatment type on δ(15)NNOx. A mass balance model indicated that sewage (>68%) remains a dominant source of nitrate pollution in seawater in Tolo Harbor. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Dissolved organic nitrogen recalcitrance and bioavailable nitrogen quantification for effluents from advanced nitrogen removal wastewater treatment facilities

    International Nuclear Information System (INIS)

    Fan, Lu; Brett, Michael T.; Jiang, Wenju; Li, Bo

    2017-01-01

    The objective of this study was to determine the composition of nitrogen (N) in the effluents of advanced N removal (ANR) wastewater treatment plants (WWTPs). This study also tested two different experimental protocols for determining dissolved N recalcitrance. An analysis of 15 effluent samples from five WWTPs, showed effluent concentrations and especially effluent composition varied greatly from one system to the other, with total nitrogen (TN) ranging between 1.05 and 8.10 mg L −1 . Nitrate (NO 3 − ) accounted for between 38 ± 32% of TN, and ammonium accounted for a further 29 ± 28%. All of these samples were dominated by dissolved inorganic nitrogen (DIN; NO 3 −  + NH 4 + ), and uptake experiments indicated the DIN fraction was as expected highly bioavailable. Dissolved organic N (DON) accounted for 20 ± 11% for the total dissolved N in these effluents, and uptake experiments indicated the bioavailability of this fraction varied between 27 ± 26% depending on the WWTP assessed. These results indicate near complete DIN removal should be the primary goal of ANR treatment systems. The comparison of bioavailable nitrogen (BAN) quantification protocols showed that the dissolved nitrogen uptake bioassay approach was clearly a more reliable way to determine BAN concentrations compared to the conventional cell yield protocol. Moreover, because the nitrogen uptake experiment was much more sensitive, this protocol made it easier to detect extrinsic factors (such as biological contamination or toxicity) that could affect the accuracy of these bioassays. Based on these results, we recommend the nitrogen uptake bioassay using filtered and autoclaved samples to quantify BAN concentrations. However, for effluent samples indicating toxicity, algal bioassays will not accurately quantify BAN. - Highlights: • DIN was the dominated N pool for most of the tested effluent samples. • DON bioavailability considerably varied depending on the WWTP assessed.

  12. Characterisation of potential aquaculture pond effluents, and ...

    African Journals Online (AJOL)

    Conventional treatment of effluents from these small-scale, low-volume operations, which discharge relatively dilute effluents infrequently, might not be cost-effective. Keywords: aquaculture–environment interaction, earthen ponds, effluent characterisation, K-means clustering, t ilapia, water quality. African Journal of Aquatic ...

  13. Disposal of the radioactive effluents at the 'Commissariat a l'Energie Atomique'. Treatment leading to evacuation into a river; Probleme du rejet des residus radioactifs liquides au CEA. Traitements aboutissant a des rejets en riviere

    Energy Technology Data Exchange (ETDEWEB)

    Duhamel,; Menoux,; Candillon, [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    The problems dealing with the treatment of the radioactive effluents at the 'Commissariat a l'Energie Atomique' have been studied in order to allow evacuation into a river - after treatment - with respect for the standards regarding radiation protection. 2) At Saclay where there is no possibility of evacuating the effluents, the liquids are directed towards Fontenay-aux-Roses by means of tank wagons. They are removed temporarily into the sewers and will be evacuated later on into the Seine. 3) ln Le Bouchet, the effluents coming from the Factory where urano-thorianite ore is treated will undergo a two stages treatment. The elimination of radium in the first phase facilitates decontamination in the second phase. 4) In Marcoule: a study of synthetic effluents of the Marcoule type is being carried on in order to perfect a selective elimination method of Sr{sup 90} and Cs{sup 137} by coprecipitation. 5) In the general case of the final evacuation into a river, the following problems have been studied: - pre-dilution of treated waters between the storing tanks and the river; - admission in the river; dilution in the river (preliminary study by means of a tracer); - evolution of the activity in the water of the river (adsorption by inert or living elements), contamination of the banks; - locating of the site; - isotopic dilution. 6) Circumstantial study of that last problem. 7) The quantity of a given product in water conditions the isotopic dilution of its radioactive isotopes. When the analysis shows the lack of an element, stable isotopes should be added in order to compensate it. 8) That method led to difficult analysis (specially as far as Sr{sup 90} is concerned), for the percentage of stable isotopes necessary to an important isotopic dilution is very low. 9) The standard regarding the quantity of Sr{sup 90} in drinking water is 8.10{sup -8} c/m{sup 3} or 4.10{sup -10} g/m{sup 3}. So a percentage of 40 {mu}g/litre of Sr is enough which is difficult to find out in

  14. Palm Oil Mill Effluent Treatment Through Combined Process Adsorption and Membrane Filtration

    Directory of Open Access Journals (Sweden)

    Muhammad Said

    2016-08-01

    Full Text Available The growth in palm oil production also leads to an Increase in the production of palm oil mill effluent (POME. Nowadays, POME was treated using an open lagoon but this method is ineffectiveness in complying with the standards for water disposal. Therefore, efficient and cohesive treatment system is highly desired to ensure the final discharge of the treated water meets the effluent discharge standards. Initially, the POME was treated through adsorption, followed by UF membranes roomates were intended to reduce COD, TSS and turbidity up to 88%, 99%, and 98%, while the final treatment of RO membranes can reduce BOD, COD and color up to 92%, 98% and 99%. To determine the optimum condition of the RO membrane, response surface methodology (RSM was used. The results showed there was correlation between all key variables. POME concentration, trans-membrane pressure, pH and time would give significant effects in reducing the parameters in POME treatment with the optimum condition of 15.77% for POME concentration, 3.73 for pH, 0.5 bar trans-membrane pressure and 5 hours for filtration time. To predict COD removal, the results were analyzed by applying the artificial neural network (ANN to derive a mathematical model.

  15. Factors Affecting Distribution of Estrogenicity in the Influents, Effluents, and Biosolids of Canadian Wastewater Treatment Plants.

    Science.gov (United States)

    Shieh, Ben H H; Louie, Alvin; Law, Francis C P

    2016-05-01

    Canadian wastewater treatment plants (WWTPs) release significant amounts of estrogenic chemicals to nearby surface waters. Environmental estrogens have been implicated as the causative agents of many developmental and reproductive problems in animals, including fish. The goals of this study were to assess the estrogenic activity in the influents, effluents, and biosolids of thirteen Canadian WWTPs using the yeast estrogen screen (YES) bioassay and to investigate whether factors, such as wastewater treatment method, sample storage, extraction efficiency, population, and summer/winter temperature had any effects on the distribution of estrogenicity in the WWTPs. Results of the study showed that estrogenicity from the influent to the effluent decreased in seven WWTPs, increased in two WWTPs, and did not change in four WWTPs during the winter. Estrogenic concentrations generally decreased in the order of biosolids > influents > effluents and ranged from 1.57 to 24.6, 1.25E-02 to 3.84E-01, and 9.46E-03 to 3.90E-01 ng estradiol equivalents/g or ml, respectively. The estrogenicity in the final effluents, but not those in the influents and biosolids, was significantly higher in the summer than the winter. Among the WWTP treatment methods, advanced, biological nutrient removal appeared to be the most effective method to remove estrogenic chemicals from wastewaters in Canada. Our studies help to identify factors or mechanisms that affect the distribution of estrogenicity in WWTPs, providing a better understanding on the discharges of estrogenic chemicals from WWTPs.

  16. Results of the F/H Effluent Treatment Facility biological monitoring program, July 1987--July 1991

    International Nuclear Information System (INIS)

    Specht, W.L.

    1992-07-01

    As required by the South Carolina Department of Health and Environmental Control (SCDHEC) under NPDES Permit SCO000175, biological monitoring was conducted in Upper Three Runs Creek to determine if discharges from the F/H Effluent Treatment Facility have adversely impacted the biotic community of the receiving stream. Data included in this summary report encompass July 1987 through July 1991. As originally designed, the F/H ETF was not expected to remove all of the mercury from the wastewater; therefore, SCDHEC specified that studies be conducted to determine if mercury was bioaccumulating in aquatic biota. Subsequent to approval of the biological monitoring program, an ion exchange column was added to the F/H ETF specifically to remove mercury, which eliminated mercury from the F/H ETF effluent. The results of the biological monitoring program indicate that at the present rate of discharge, the F/H ETF effluent has not adversely affected the receiving stream with respect to any of the parameters that were measured. The effluent is not toxic at the in-stream waste concentration and there is no evidence of mercury bioaccumulation

  17. Treatment efficiency of effluent prawn culture by wetland with floating aquatic macrophytes arranged in series

    Directory of Open Access Journals (Sweden)

    MNP Henares

    Full Text Available The efficiency of a series of wetland colonized with Eichhornia crassipes and Salvinia molesta to treat the effluent of a giant river prawn (Macrobrachium rosenbergii broodstock pond was evaluated in this study. The experimental design was completely randomized and was performed in 9 rectangular tanks (1.6 m3 with three treatments (constructed wetlands and three replicates. The treatment types included: a wetland colonized with E. crassipes and S. molesta (EcSm arranged sequentially, a wetland with E. crassipes only (Ec and a wetland with S. molesta only (Sm. The means of suspended particulate material (SPM, total inorganic nitrogen (TIN, total Kjeldahl nitrogen (TKN, P-orthophosphate (PO4-P and total phosphorus (TP of the treated effluents were compared using ANOVA followed by Tukey's test (P<0.05. The effluent treated in Ec and EcSm wetlands exhibited lower SPM concentrations. The Ec wetland reduced TIN, TKN, PO4-P and TP by 46.0, 43.7, 44.4 and 43.6%, respectively. In the EcSm wetland, the reduction of TIN (23.0%, TKN (33.7% and PO4-P (26.7% was similar to the Sm wetland (19.8% TIN, 30.9% TKN and 23.8% PO4-P. The Ec wetland was more efficient in treating pond effluent due likely to the higher root surface of E. crassipes, which forms an extensive area favorable to retention and adsorption of debris and absorption of nutrients.

  18. Biological treatment of paper pulp effluents: the application of ligninolytic white rot-fungi

    Energy Technology Data Exchange (ETDEWEB)

    Martin, C; Fajardo, S.; Manzanares, P.

    1996-07-01

    Biological treatments using white-rot fungi, based in their ability to degrade lignin, can constitute an interesting approach to remove colour and toxic compounds usually contained in paper pulp effluents due to the presence of recalcitrant lignin derived molecules. In this work, strains A-137 and A-136 (IJFM collection, CIB-CSIC, Madrid) of Trameles versicolor, a ligninolytic white-rot fungus that have been frequently reported in relation to degradation of lignin, have been used for decolorisation studies of the straw alkaline-pulping effluent from SAICA factory (Zaragoza, Spain). From results obtained it can be concluded that decolorisation percentages about 80% can be obtained in 4-6 days (for maximum initial colour effluent between 12,000 and 15,000 CU) and total phenolics content can be reduced in about 90%. Mn-dependent peroxidase (about 20 IU/I) and high values of laccase activities (up to 700 IU/I) were produced, what may be of great interest to set up ligninolytic enzymes production processes for industrial uses. (Author) 19 refs.

  19. Biological treatment of paper pulp effluents: the application of ligninolytic white rot-fungi

    International Nuclear Information System (INIS)

    Martin, C; Fajardo, S.; Manzanares, P.

    1996-01-01

    Biological treatments using white-rot fungi, based in their ability to degrade lignin, can constitute an interesting approach to remove colour and toxic compounds usually contained in paper pulp effluents due to the presence of recalcitrant lignin derived molecules. In this work, strains A-137 and A-136 (IJFM collection, CIB-CSIC, Madrid) of Trameles versicolor, a ligninolytic white-rot fungus that have been frequently reported in relation to degradation of lignin, have been used for decolorisation studies of the straw alkaline-pulping effluent from SAICA factory (Zaragoza, Spain). From results obtained it can be concluded that decolorisation percentages about 80% can be obtained in 4-6 days (for maximum initial colour effluent between 12,000 and 15,000 CU) and total phenolics content can be reduced in about 90%. Mn-dependent peroxidase (about 20 IU/I) and high values of laccase activities (up to 700 IU/I) were produced, what may be of great interest to set up ligninolytic enzymes production processes for industrial uses. (Author) 19 refs

  20. Combination of biological treatment of waste air and liquid effluents in small and medium-sized businesses by using spherical carrier media in exchange with each other. Final report; Kombination der biologischen Behandlung von Abluft- und Abwasserreinigung in kleinen und mittleren Unternehmen durch die Verwendung von kugeligen Traegermaterialien im gegenseitigen Austausch. Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Kunz, P.M.; Brunk, M.; Bentz, P.; Bach, K.; Marcos del Rio, O.; Stahl, B.; Wolf, C.

    2002-05-08

    A combined system for biological treatment of solvent-contaminated liquid and gaseous effluents was to be constructed. The system was to be mobile for demonstration purposes in industrial processes and was to serve for dimensioning of full-scale systems. The system works by a combined process via exchange of spherical carriers with a growth of micro-organisms. Two pilot systems of the Institut fuer Biologische Verfahrenstechnik, one for liquid and one for gaseous effluents, were combined for this purpose, ensuring exchange of carrier materials between the two units. (orig.) [German] Aufgabe im Rahmen dieses F+E-Vorhabens war es gewesen, eine kombinierte biologische Abluft- und Abwasserreinigungsanlage - speziell fuer loesungsmittelhaltige Abluft und Abwaesser - zu untersuchen. Dazu sollte eine Anlage aufgebaut werden, die auch als Demonstrations- und Versuchsanlage zu Industriebetrieben gebracht und dort zur Dimensionierung von full-scale-Anlage eingesetzt werden kann. Idee fuer dieses Vorhaben war gewesen, die Kombination beider Behandlungssysteme ueber den Austausch von mit Mikroorganismen bewachsenem Traegermaterial herzustellen. Am Institut fuer Biologische Verfahrenstechnik existierte bereits eine Pilotanlage fuer die biologische Abwasserreinigung mit kugeligem Traegermaterial (Vario-Bio-Reaktor) und eine Pilotanlage fuer die biologische Behandlung von Abluft nach dem Trickling-Filter-Prinzip mit ebenfalls kugeligem Traegermaterial. Diese beiden Anlagen sollten miteinander kombiniert und der Austausch des Traegermaterials hergestellt werden. (orig.)

  1. Treatment of municipal wastewater treatment plant effluents with modified photo-Fenton as a tertiary treatment for the degradation of micro pollutants and disinfection.

    Science.gov (United States)

    Klamerth, Nikolaus; Malato, Sixto; Agüera, Ana; Fernández-Alba, Amadeo; Mailhot, Gilles

    2012-03-06

    The goal of this paper was to develop a modified photo-Fenton treatment able to degrade micro pollutants in municipal wastewater treatment plant (MWTP) effluents at a neutral pH with minimal iron and H(2)O(2) concentrations. Complexation of Fe by ethylenediamine-N,N'-disuccinic acid (EDDS) leads to stabilization and solubilization of Fe at natural pH. Photo-Fenton experiments were performed in a pilot compound parabolic collector (CPC) solar plant. Samples were treated with solid phase extraction (SPE) and analyzed by HPLC-Qtrap-MS. The rapid degradation of contaminants within the first minutes of illumination and the low detrimental impact on degradation of bicarbonates present in the water suggested that radical species other than HO(•) are responsible for the efficiency of such photo-Fenton process. Disinfection of MWTP effluents by the same process showed promising results, although disinfection was not complete.

  2. Treatment of colored effluents with lignin-degrading enzymes: An emerging role of marine-derived fungi

    Digital Repository Service at National Institute of Oceanography (India)

    Raghukumar, C.; DeSouza-Ticlo, D.; Verma, A.K.

    laccase, manganese-peroxidase and lignin peroxidases are useful in the treatment of colored industrial effluents and other xenobiotics. Free mycelia, mycelial pellets, immobilized fungi or their lignin-degrading enzymes fromterrestrial fungi have been...

  3. Treatment of real industrial wastewaters through nano-TiO2 and nano-Fe2O3 photocatalysis: case study of mining and kraft pulp mill effluents.

    Science.gov (United States)

    Nogueira, V; Lopes, I; Rocha-Santos, T A P; Gonçalves, F; Pereira, R

    2018-06-01

    High quantities of industrial wastewaters containing a wide range of organic and inorganic pollutants are being directly discharged into the environment, sometimes without proper treatment. Nanotechnology has a tremendous potential improving the existing treatments or even develop new treatment solutions. In this study, nano-TiO 2 or nano-Fe 2 O 3 was used for the photocatalytic treatment of kraft pulp mill effluent and mining effluent. The experiments with the organic effluent lead to reduction percentages of 93.3%, 68.4% and 89.8%, for colour, aromatic compounds and chemical oxygen demand, respectively, when treated with nano-TiO 2 /H 2 O 2 /UV and nano-Fe 2 O 3 /H 2 O 2 /UV, at pH 3.0. Significant removal of metals from the mining effluent was recorded but only for Zn, Al and Cd, the highest removal attained with 1.0 g L -1 of nano-TiO 2 /UV and nano-Fe 2 O 3 /UV. Regarding the toxicity of the organic effluent to Vibrio fischeri, it was reduced with the treatments combining the oxidant and the catalyst. However, for the inorganic effluent, the best reduction was achieved using 1.0 g L -1 of catalyst. In fact, the increase in dose of the catalyst, especially for nano-TiO 2 , enhanced toxicity reduction. Our results have shown that the use of these NMs seemed to be more effective in the organic effluent than in metal-rich effluent.

  4. Enhanced performance of a submerged membrane bioreactor with powdered activated carbon addition for municipal secondary effluent treatment

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Hongjun, E-mail: hjlin@zjnu.cn [College of Geography and Environmental Sciences, Zhejiang Normal University, 688 Yingbin Avenue, Jinhua, Zhejiang Province 321004 (China); Wang, Fangyuan; Ding, Linxian; Hong, Huachang [College of Geography and Environmental Sciences, Zhejiang Normal University, 688 Yingbin Avenue, Jinhua, Zhejiang Province 321004 (China); Chen, Jianrong, E-mail: cjr@zjnu.cn [College of Geography and Environmental Sciences, Zhejiang Normal University, 688 Yingbin Avenue, Jinhua, Zhejiang Province 321004 (China); Lu, Xiaofeng [Shanghai Institute of Applied Physics, Chinese Academy of Science, Shanghai 201800 (China)

    2011-09-15

    Highlights: {yields} The first study to investigate the feasibility of PAC-MBR process treating municipal secondary effluent. {yields} The study revealed that most organics in the secondary effluent were low molecular weight (MW) substances, which could be retained in the reactor and then removed to some extent by PAC-MBR process. {yields} The study suggested that the action of biomass and the PAC is mutual and synergistic. - Abstract: The aim of this study was to investigate the feasibility of PAC-MBR process treating municipal secondary effluent. Two laboratory-scale submerged MBRs (SMBR) with and without PAC addition were continuously operated in parallel for secondary effluent treatment. Approximately 63%TOC, 95% NH{sub 4}{sup +}-N and 98% turbidity in secondary effluent were removed by the PAC-MBR process. Most organics in the secondary effluent were found to be low molecular weight (MW) substances, which could be retained in the reactor and then removed to some extent by using PAC-MBR process. Parallel experiments showed that the addition of PAC significantly increased organic removal and responsible for the largest fraction of organic removal. Membrane fouling analysis showed the enhanced membrane performance in terms of sustainable operational time and filtration resistances by PAC addition. Based on these results, the PAC-MBR process was considered as an attractive option for the reduction of pollutants in secondary effluent.

  5. Enhanced performance of a submerged membrane bioreactor with powdered activated carbon addition for municipal secondary effluent treatment

    International Nuclear Information System (INIS)

    Lin, Hongjun; Wang, Fangyuan; Ding, Linxian; Hong, Huachang; Chen, Jianrong; Lu, Xiaofeng

    2011-01-01

    Highlights: → The first study to investigate the feasibility of PAC-MBR process treating municipal secondary effluent. → The study revealed that most organics in the secondary effluent were low molecular weight (MW) substances, which could be retained in the reactor and then removed to some extent by PAC-MBR process. → The study suggested that the action of biomass and the PAC is mutual and synergistic. - Abstract: The aim of this study was to investigate the feasibility of PAC-MBR process treating municipal secondary effluent. Two laboratory-scale submerged MBRs (SMBR) with and without PAC addition were continuously operated in parallel for secondary effluent treatment. Approximately 63%TOC, 95% NH 4 + -N and 98% turbidity in secondary effluent were removed by the PAC-MBR process. Most organics in the secondary effluent were found to be low molecular weight (MW) substances, which could be retained in the reactor and then removed to some extent by using PAC-MBR process. Parallel experiments showed that the addition of PAC significantly increased organic removal and responsible for the largest fraction of organic removal. Membrane fouling analysis showed the enhanced membrane performance in terms of sustainable operational time and filtration resistances by PAC addition. Based on these results, the PAC-MBR process was considered as an attractive option for the reduction of pollutants in secondary effluent.

  6. Treatment of turtle aquaculture effluent by an improved multi-soil-layer system.

    Science.gov (United States)

    Song, Ying; Huang, Yu-ting; Ji, Hong-fang; Nie, Xin-jun; Zhang, Zhi-yuan; Ge, Chuan; Luo, An-cheng; Chen, Xin

    2015-02-01

    Concentrated turtle aquaculture effluent poses an environmental threat to water bodies, and therefore needs to be treated prior to disposal. This study was conducted to assess the effect of multi-soil-layer (MSL) systems treating turtle aquaculture effluent with adding different amounts of sludge. Four MSL systems were constructed with dry weight ratios of sludge with 0%, 5%, 10%, and 20% (MSL 1, MSL 2, MSL 3, and MSL 4, respectively). The turtle aquaculture effluent had an average chemical oxygen demand (COD), ammonia nitrogen (NH4(+)-N) and total nitrogen (TN) concentration of 288.4, 213.4, and 252.0 mg/L, respectively. The COD/TN (C/N) ratio was 1.2. The results showed that the four MSL systems could effectively treat the COD, NH4(+)-N, and TN, and MSL 4 showed significantly improved NH4(+)-N removal efficiency, suggesting the potential of sludge addition to improve the turtle aquaculture effluent treatment. The average COD, TN, and NH4(+)-N removal efficiencies of MSL 4 were 70.3%, 66.5%, and 72.7%, respectively. To further interpret the contribution of microorganisms to the removal, the microbial community compositions and diversities of the four MSL systems were measured. Comparisons of the denaturing gradient gel electrophoresis (DGGE) profiles revealed that the amount of nitrifying bacteria and diversity in MSL 4 were higher than those in the other three systems. We concluded that adding 20% of sludge improved the NH4(+)-N removal and stability of the system for nitrification, due to the enrichment of the nitrifying bacteria in MSL 4.

  7. The conceptual flowsheet of effluent treatment during total gelation of uranium process for preparing ceramic UO2 particles of high temperature gas-cooled reactors

    International Nuclear Information System (INIS)

    Quan Ying; Chen Xiaotong; Wang Yang; Liu Bing; Tang Yaping; Tang Chunhe

    2014-01-01

    Today, more and more people pay attention to the environmental protection and ecological environment. Along with the development of nuclear industry, many radioactive effluents may be discharged into environment, which can lead to the pollutions of water, atmosphere and soil. So radioactive effluents including low-activity and medium-level wastes solution treatments have been becoming one of significant subjects. High temperature gas-cooled reactor (HTR) is one of advanced nuclear reactors owing to its reliability, security and broad application in which the fabrication of spherical fuel element is a key technology. During the production of spherical fuel elements, the radioactive effluent treatment is necessary. Referring to the current treatment technologies and methods, the conceptual flowsheet of low-level radioactive effluent treatment during preparing spherical fuel elements was summarized which met the 'Zero Emission' demand. (authors)

  8. Investigation of TC and TSS Removal Efficiencies at Ahvaz West WTP Effluent Using the Land‒plant Treatment Process

    Directory of Open Access Journals (Sweden)

    Afshin Takdastan

    2015-12-01

    Full Text Available Although the conventional (primary and secondary treatment processes are known to remove up to 95–99% of some micro-organisms, they do not provide adequate treatment to make the effluent suitable for direct reuse, mainly due to the presence of high concentrations of pathogenic microorganisms. Obtaining reusable effluents, therefore, requires the use of processes that can be justified both technical and economic grounds. One such indigenous, low cost option is the land-plant process that can be used for advanced wastewater treatment. It is the objective of the present study to determine the efficiency of the local soil in Ahvaz and that of the vetiver plant in reducing the microbial load in the effluent from municipal wastewater treatment plants. A pilot study was thus carried out including three Lysimeters installed in West Ahvaz Wastewater Treatment Plant. Local soil was used in one Lysimeter, local soil with vetiver plant in the second one, and an artificial assortment of soil comprising local soil, silica sand (0.5-1mm, and sand (15-30mm in the third. In addition, the effluent from the secondary settling outlet at the WTP was transferred by pumping at the three filtration rates of 0.2, 0.6, and 1 ml/min into the system with three replications for each rate and samples were collected from both inlet and outlet flows. The average removal efficiencies of Total Suspended Solids (TSS and Total Coliform (TC in the effluent from the three Lysimeters with local soil with vetiver, local soil without vetiver, and artificial soil assortment for the filtration rate of 0.2 ml/min were: 67.75% and 99.7%, 58.33% and 99.6%, and 56.25% and 99.5%, respectively. For a filtration rate of 0.6 ml/min, these values were: 53.33% and 98.93%, 48.8 and 98.77%, and 47.68% and 98.64%. Finally, the values obtained for a filtration rate of 0.6 ml/min were: 50% and 93.96%, 46.42 and 91.34%, and 44/04% and 88/81%, respectively. The results from the study showed that the

  9. Final treatment of liquid radioactive wastes

    International Nuclear Information System (INIS)

    Svolik, S.

    2004-01-01

    Final treatment of liquid radioactive wastes which are produced by 1 st and 2 nd bloc of the Mochovce NPP, prepares the NPP in its natural range. The purpose of the equipment is liquidation of wastes, which are formed at production. Wastes are warehoused in the building of active auxiliary plants in the present time, where are reservoirs in which they are deposited. Because they are already feeling and in 2006 year they should be filled definitely, it is necessary to treat them in that manner, so as they may be liquidated. Therefore the Board of directors of the Slovenske elektrarne has disposed about construction of final treatment of liquid radioactive wastes in the Mochovce NPP. Because of transport the wastes have to be treated in the locality of power plant. Technically, the final treatment of the wastes will be interconnected with building of active operation by bridges. These bridges will transport the wastes for treatment into processing centre

  10. An investigation into the removal of Salmonella and enteric indicator bacteria from the separated liquid fraction of raw or anaerobically digested pig manure using novel on-farm woodchip biofilters.

    Science.gov (United States)

    McCarthy, G; Lawlor, P G; Carney, K N; Zhan, X; Gutierrez, M; Gardiner, G E

    2015-05-01

    The objective was to investigate the removal of Salmonella and enteric indicator bacteria from the liquid fraction of raw and anaerobically digested (AD) pig manure in woodchip biofilters over a 14 week (98 day) period. Antibiotic susceptible Salmonella Infantis was detected in one influent material (liquid fraction of raw manure) on two occasions but was not found in the effluent at any time point. Furthermore, mean coliform reductions of 56% were observed in the biofilters treating the liquid fraction of raw manure. However, a mean increase of 228% was found in those treating the liquid from AD manure, despite the fact that the microbial challenge to these biofilters was lower. In addition, relatively high coliform counts were still present in the effluent from both biofilter treatments, especially in the systems treating the liquid fraction of AD manure. However, findings for Escherichia coli and Enterococcus were more promising, with reductions observed for both treatments (10 and 18.5% for E. coli and 71 and 87% for Enterococcus). Moreover, E. coli and Enterococcus were at, or just above, the limit of detection in the final effluents. Overall, although, there are no microbial limits for discharge or washwaters, the woodchip filter effluent would appear safe for discharge to waterways or use on-farm as regards Salmonella, E. coli and Enterococcus but not coliform. In conclusion, woodchip biofilters offer potential as a low-cost sustainable novel treatment option for the removal of pathogens from the liquid fraction of pig manure. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Removal of pharmaceuticals and unspecified contaminants in sewage treatment effluents by activated carbon filtration and ozonation: Evaluation using biomarker responses and chemical analysis.

    Science.gov (United States)

    Beijer, Kristina; Björlenius, Berndt; Shaik, Siraz; Lindberg, Richard H; Brunström, Björn; Brandt, Ingvar

    2017-06-01

    Traces of active pharmaceutical ingredients (APIs) and other chemicals are demonstrated in effluents from sewage treatment plants (STPs) and they may affect quality of surface water and eventually drinking water. Treatment of effluents with granular activated carbon (GAC) or ozone to improve removal of APIs and other contaminants was evaluated at two Swedish STPs, Käppala and Uppsala (88 and 103 APIs analyzed). Biomarker responses in rainbow trout exposed to regular and additionally treated effluents were determined. GAC and ozone treatment removed 87-95% of the total concentrations of APIs detected. In Käppala, GAC removed 20 and ozonation (7 g O 3 /m 3 ) 21 of 24 APIs detected in regular effluent. In Uppsala, GAC removed 25 and ozonation (5.4 g O 3 /m 3 ) 15 of 25 APIs detected in effluent. GAC and ozonation also reduced biomarker responses caused by unidentified pollutants in STP effluent water. Elevated ethoxyresorufin-O-deethylase (EROD) activity in gills was observed in fish exposed to effluent in both STPs. Gene expression analysis carried out in Käppala showed increased concentrations of cytochrome P450 (CYP1As and CYP1C3) transcripts in gills and of CYP1As in liver of fish exposed to effluent. In fish exposed to GAC- or ozone-treated effluent water, gill EROD activity and expression of CYP1As and CYP1C3 in gills and liver were generally equal to or below levels in fish held in tap water. The joint application of chemical analysis and sensitive biomarkers proved useful for evaluating contaminant removal in STPs with new technologies. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Identification of effluent organic matter fractions responsible for low-pressure membrane fouling

    KAUST Repository

    Filloux, Emmanuelle

    2012-11-01

    Anion exchange resin (AER), powder activated carbon (PAC) adsorption and ozonation treatments were applied on biologically treated wastewater effluent with the objective to modify the effluent organic matter (EfOM) matrix. Both AER and PAC led to significant total organic carbon (TOC) removal, while the TOC remained nearly constant after ozonation. Liquid Chromatography-Organic Carbon Detection (LC-OCD) analysis showed that the AER treatment preferentially removed high and intermediate molecular weight (MW) humic-like structures while PAC removed low MW compounds. Only a small reduction of the high MW colloids (i.e. biopolymers) was observed for AER and PAC treatments. Ozonation induced a large reduction of the biopolymers and an important increase of the low MW humic substances (i.e. building blocks).Single-cycle microfiltration (MF) and ultrafiltration (UF) tests were conducted using commercially available hollow fibres at a constant flux. After reconcentration to their original organic carbon content, the EfOM matrix modified by AER and PAC treatments exhibited higher UF membrane fouling compared to untreated effluent; result that correlated with the higher concentration of biopolymers. On the contrary, ozonation which induced a significant degradation of the biopolymers led to a minor flux reduction for both UF and MF filtration tests. Based on a single filtration, results indicate that biopolymers play a major role in low pressure membrane fouling and that intermediate and low MW compounds have minor impact. Thus, this approach has shown to be a valid methodology to identify the foulant fractions of EfOM. © 2012 Elsevier Ltd.

  13. Liquid by-products from fish canning industry as sustainable sources of ω3 lipids.

    Science.gov (United States)

    Monteiro, Ana; Paquincha, Diogo; Martins, Florinda; Queirós, Rui P; Saraiva, Jorge A; Švarc-Gajić, Jaroslava; Nastić, Nataša; Delerue-Matos, Cristina; Carvalho, Ana P

    2018-08-01

    Fish canning industry generates large amounts of liquid wastes, which are discarded, after proper treatment to remove the organic load. However, alternative treatment processes may also be designed in order to target the recovery of valuable compounds; with this procedure, these wastewaters are converted into liquid by-products, becoming an additional source of revenue for the company. This study evaluated green and economically sustainable methodologies for the extraction of ω3 lipids from fish canning liquid by-products. Lipids were extracted by processes combining physical and chemical parameters (conventional and pressurized extraction processes), as well as chemical and biological parameters. Furthermore, LCA was applied to evaluate the environmental performance and costs indicators for each process. Results indicated that extraction with high hydrostatic pressure provides the highest amounts of ω3 polyunsaturated fatty acids (3331,5 mg L -1 effluent), apart from presenting the lowest environmental impact and costs. The studied procedures allow to obtain alternative, sustainable and traceable sources of ω3 lipids for further applications in food, pharmaceutical and cosmetic industries. Additionally, such approach contributes towards the organic depuration of canning liquid effluents, therefore reducing the overall waste treatment costs. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. Estimation of low level gross alpha activities in the radioactive effluent using liquid scintillation counting technique

    International Nuclear Information System (INIS)

    Bhade, Sonali P.D.; Johnson, Bella E.; Singh, Sanjay; Babu, D.A.R.

    2012-01-01

    A technique has been developed for simultaneous measurement of gross alpha and gross beta activity concentration in low level liquid effluent samples in presence of higher activity concentrations of tritium. For this purpose, alpha beta discriminating Pulse Shape Analysis Liquid Scintillation Counting (LSC) technique was used. Main advantages of this technique are easy sample preparation, rapid measurement and higher sensitivity. The calibration methodology for Quantulus1220 LSC based on PSA technique using 241 Am and 90 Sr/ 90 Y as alpha and beta standards respectively was described in detail. LSC technique was validated by measuring alpha and beta activity concentrations in test samples with known amount of 241 Am and 90 Sr/ 90 Y activities spiked in distilled water. The results obtained by LSC technique were compared with conventional planchet counting methods such as ZnS(Ag) and end window GM detectors. The gross alpha and gross beta activity concentrations in spiked samples, obtained by LSC technique were found to be within ±5% of the reference values. (author)

  15. Lagrangian sampling of wastewater treatment plant effluent in Boulder Creek, Colorado, and Fourmile Creek, Iowa, during the summer of 2003 and spring of 2005--Hydrological and chemical data

    Science.gov (United States)

    Barber, Larry B.; Keefe, Steffanie H.; Kolpin, Dana W.; Schnoebelen, Douglas J.; Flynn, Jennifer L.; Brown, Gregory K.; Furlong, Edward T.; Glassmeyer, Susan T.; Gray, James L.; Meyer, Michael T.; Sandstrom, Mark W.; Taylor, Howard E.; Zaugg, Steven D.

    2011-01-01

    This report presents methods and data for a Lagrangian sampling investigation into chemical loading and in-stream attenuation of inorganic and organic contaminants in two wastewater treatment-plant effluent-dominated streams: Boulder Creek, Colorado, and Fourmile Creek, Iowa. Water-quality sampling was timed to coincide with low-flow conditions when dilution of the wastewater treatment-plant effluent by stream water was at a minimum. Sample-collection times corresponded to estimated travel times (based on tracer tests) to allow the same "parcel" of water to reach downstream sampling locations. The water-quality data are linked directly to stream discharge using flow- and depth-integrated composite sampling protocols. A range of chemical analyses was made for nutrients, carbon, major elements, trace elements, biological components, acidic and neutral organic wastewater compounds, antibiotic compounds, pharmaceutical compounds, steroid and steroidal-hormone compounds, and pesticide compounds. Physical measurements were made for field conditions, stream discharge, and time-of-travel studies. Two Lagrangian water samplings were conducted in each stream, one in the summer of 2003 and the other in the spring of 2005. Water samples were collected from five sites in Boulder Creek: upstream from the wastewater treatment plant, the treatment-plant effluent, and three downstream sites. Fourmile Creek had seven sampling sites: upstream from the wastewater treatment plant, the treatment-plant effluent, four downstream sites, and a tributary. At each site, stream discharge was measured, and equal width-integrated composite water samples were collected and split for subsequent chemical, physical, and biological analyses. During the summer of 2003 sampling, Boulder Creek downstream from the wastewater treatment plant consisted of 36 percent effluent, and Fourmile Creek downstream from the respective wastewater treatment plant was 81 percent effluent. During the spring of 2005

  16. Membrane technologies for liquid radioactive waste treatment

    International Nuclear Information System (INIS)

    Chmielewski, A.G.; Harasimowicz, M.; Zakrzewska-Trznadel, G.

    1998-01-01

    At Institute of Nuclear Chemistry and Technology (INCT) the membrane method for purification of radioactive wastes applied such processes as ultrafiltration (UF), 'seeded' ultrafiltration and reverse osmosis (RO) was developed. On the basis of the results obtained in laboratory experiments the pilot plant for radioactive effluents treatment was built. The plant was composed of UF unit (AMICON H 26P30 capillary module) and two RO units (NITTO NTR 739 HF S-4 spiral wound LPRO modules). The capacity of the pilot plant was up to 200 L/h and the specific activity of wastes purified in the system - below 10 4 Bq/L. Decontamination factor for entire system is higher than 5 x10 3 . Another possibility for radioactive wastes treatment is membrane distillation (MD), non-isothermal process employing hydrophobic polymer membrane, which is developed at INCT now. Preliminary tests with liquid radwaste were carried out on laboratory unit with permeation test-cell holding flat sheet membrane. As a hydrophobic barrier membranes made of two polymers were used: polytetrafluoroethylene (PTFE) and polypropylene (PP). The process was arranged in direct contact membrane distillation configuration. The permeate condensed directly in the cold stream (distilled water) and retentate was enriched in radionuclides. The further experiments carried out with capillary module BFMF 06-30-33 (Euro-Sep Ltd.) with polypropylene capillaries, diameter 0.33 mm and cut off 0.6 μm proved previous results. A pilot plant employing GORE-TEX membrane distillation was constructed. The plant can clean the low-level radioactive wastes from nuclear centre, at a throughput about 0.05 m 3 /h

  17. Dissolved organic nitrogen recalcitrance and bioavailable nitrogen quantification for effluents from advanced nitrogen removal wastewater treatment facilities.

    Science.gov (United States)

    Fan, Lu; Brett, Michael T; Jiang, Wenju; Li, Bo

    2017-10-01

    The objective of this study was to determine the composition of nitrogen (N) in the effluents of advanced N removal (ANR) wastewater treatment plants (WWTPs). This study also tested two different experimental protocols for determining dissolved N recalcitrance. An analysis of 15 effluent samples from five WWTPs, showed effluent concentrations and especially effluent composition varied greatly from one system to the other, with total nitrogen (TN) ranging between 1.05 and 8.10 mg L -1 . Nitrate (NO 3 - ) accounted for between 38 ± 32% of TN, and ammonium accounted for a further 29 ± 28%. All of these samples were dominated by dissolved inorganic nitrogen (DIN; NO 3 -  + NH 4 + ), and uptake experiments indicated the DIN fraction was as expected highly bioavailable. Dissolved organic N (DON) accounted for 20 ± 11% for the total dissolved N in these effluents, and uptake experiments indicated the bioavailability of this fraction varied between 27 ± 26% depending on the WWTP assessed. These results indicate near complete DIN removal should be the primary goal of ANR treatment systems. The comparison of bioavailable nitrogen (BAN) quantification protocols showed that the dissolved nitrogen uptake bioassay approach was clearly a more reliable way to determine BAN concentrations compared to the conventional cell yield protocol. Moreover, because the nitrogen uptake experiment was much more sensitive, this protocol made it easier to detect extrinsic factors (such as biological contamination or toxicity) that could affect the accuracy of these bioassays. Based on these results, we recommend the nitrogen uptake bioassay using filtered and autoclaved samples to quantify BAN concentrations. However, for effluent samples indicating toxicity, algal bioassays will not accurately quantify BAN. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Evaluation code for the dose due to the discharges of liquid effluents of the Embalse nuclear power plant

    International Nuclear Information System (INIS)

    Lopez, Fabio O.; Boutet, Luis I.; Bruno, Hector A.; Gavini, Ricardo M.

    2004-01-01

    A new methodology is presented to assess the evaluation of the radiological impact to the population, due to the discharges to the environment of liquids effluents of Central Nuclear Embalse (CNE), located in the Province of Cordoba (Argentina). In order to carry out the dose evaluation, a code denominated EDDELIQ was developed, in this code the calculation of the radionuclides concentration in the water lake is made by means of a simple physical model of the type of complete mixture. The physical model is solved numerically by means of Runge Kutta method of second order. (author)

  19. Nuclear plant refurbishment calls for patience. [Construction of radioactive effluent plant

    Energy Technology Data Exchange (ETDEWEB)

    Henly, Anna

    1989-08-01

    All nuclear power plants produce a small quantity of liquid effluent from wash hand basins, showers and surface drains on the site. The effluent is termed low-level radioactive waste and under the 'Radioactive Substances Act' can be discharged into estuaries or the sea. Before a controlled discharge can be made the effluent has to be chemically treated and have any radioactive particulate matter removed. The replacing of the radioactive effluent plant at the Berkeley nuclear power station in the United Kingdom is described, with particular reference to the vigorous safety standards and quality assurance programme operated by the Central Electricity Generating Board. (author).

  20. Calculation of the annual radiation dose to the population in the vicinity of nuclear installations due to liquid effluents

    International Nuclear Information System (INIS)

    Gans, I.

    1991-01-01

    Since 1974, assessments of radiation exposure due to the emission of radioactive substances with liquid effluents have been done by the Institut fuer Wasser-, Boden- und Lufhygiene of the Federal Health Office and data have bee published in the annual reports in the series 'Umweltradioaktivitaet und Strahlenbelastung'. The paper explaines the radioecological models of ABG and AVV as far as they relate to the wastewater pathway, as well as the required modifications. Individual aspects of computation are explained referring to the dose calculations for 1989. (orig./DG) [de

  1. Southeast Regional Wastewater Treatment Plant Facilities Improvements Project and Geysers Effluent Pipeline Project. Draft EIR/EIS, Volume 2 of 2: Appendices

    International Nuclear Information System (INIS)

    1994-01-01

    The Southeast Regional Wastewater Treatment Plant (SERWTP) Facilities Improvement Plan and Geysers Effluent Pipeline and Effluent Injection Project are proposed as a plan to provide expanded wastewater treatment capabilities and to dispose of the effluent by injection in The Geysers geothermal field for purposes of power production. The project is located predominantly in the County of Lake, California, and also in part of Sonoma County. The plan includes various conventional facilities improvements in wastewater treatment to a secondary level of treatment at the SWERWTP. The plan includes facilities to convey the treated effluent in a 26-mile, 24-inch inside diameter pipeline to the Southeast Geysers. The wastewater from the SERWTP would be supplemented by raw lake water diverted from nearby Clear Lake. At The Geysers, the effluent would be directed into a system of distribution lines to wells. In the geothermal reservoir, the water will be converted to steam and collected in production wells that will direct the steam to six existing power plants. This document is a summary of a combined full Environmental Impact Report (EIR) and Environmental Impact Statement (EIS). The EIR/EIS describes the environmental impacts of the various components of the project. Mitigation measures are suggested for reducing impacts to a less than significant level. This report contains appendices A and B. Appendix A contains notices of preparation/notices of intent and EIR/EIS scoping comments. Appendix B contains GeothermEx, Inc., analysis of Geothermal Reservoir Effects and Induced Seismicity

  2. LC-MS/MS determination of antiretroviral drugs in influents and effluents from wastewater treatment plants in KwaZulu-Natal, South Africa.

    Science.gov (United States)

    Abafe, Ovokeroye A; Späth, Jana; Fick, Jerker; Jansson, Stina; Buckley, Chris; Stark, Annegret; Pietruschka, Bjoern; Martincigh, Bice S

    2018-06-01

    South Africa has the largest occurrence of the human immune deficiency virus (HIV) in the world but has also implemented the largest antiretroviral (ARV) treatment programme. It was therefore of interest to determine the presence and concentrations of commonly used antiretroviral drugs (ARVDs) and, also, to determine the capabilities of wastewater treatment plants (WWTPs) for removing ARVDs. To this end, a surrogate standard based LC-MS/MS method was optimized and applied for the detection of thirteen ARVDs used in the treatment and management of HIV/acquired immune deficiency syndrome (HIV/AIDS) in two major and one modular WWTP in the eThekwini Municipality in KwaZulu-Natal, South Africa. The method was validated and the detection limits fell within the range of 2-20 ng L -1 . The analytical recoveries for the ARVDs were mainly greater than 50% with acceptable relative standard deviations. The concentration values ranged from effluent) in a decentralized wastewater treatment facility (DEWATS); effluent) in Northern WWTP and 61-34000 ng L -1 (influent), effluent) in Phoenix WWTP. Whilst abacavir, lamivudine and zidovudine were almost completely removed from the effluents, atazanavir, efavirenz, lopinavir and nevirapine persisted in the effluents from all three WWTPs. To estimate the ecotoxicological risks associated with the discharge of ARVDs, a countrywide survey focussing on the occurrence of ARVDs in WWTPs, surface and fresh water bodies, and aquatic organisms, is necessary. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Distribution of effluent injected into the Boulder Zone of the Floridan aquifer system at the North District Wastewater Treatment Plant, southeastern Florida, 1997–2011

    Science.gov (United States)

    King, Jeffrey N.; Decker, Jeremy D.

    2018-02-09

    Nonhazardous, secondarily treated, domestic wastewater (effluent) has been injected about 1 kilometer below land surface into the Boulder Zone of the Floridan aquifer system at the North District Wastewater Treatment Plant in southeastern Florida. The Boulder Zone contains saline, nonpotable water. Effluent transport out of the injection zone is a risk of underground effluent injection. At the North District Wastewater Treatment Plant, injected effluent was detected outside the Boulder Zone. The U.S. Geological Survey, in cooperation with Miami-Dade Water and Sewer Department, investigated effluent transport from the Boulder Zone to overlying permeable zones in the Floridan aquifer system.One conceptual model is presented to explain the presence of effluent outside of the injection zone in which effluent injected into the Boulder Zone was transported to the Avon Park permeable zone, forced by buoyancy and injection pressure. In this conceptual model, effluent injected primarily into the Boulder Zone reaches a naturally occurring feature (a karst-collapse structure) near an injection well, through which the effluent is transported vertically upward to the uppermost major permeable zone of the Lower Floridan aquifer. The effluent is then transported laterally through the uppermost major permeable zone of the Lower Floridan aquifer to another naturally occurring feature northwest of the North District Wastewater Treatment Plant, through which it is then transported vertically upward into the Avon Park permeable zone. In addition, a leak within a monitoring well, between monitoring zones, allowed interflow between the Avon Park permeable zone and the Upper Floridan aquifer. A groundwater flow and effluent transport simulation of the hydrogeologic system at the North District Wastewater Treatment Plant, based on the hypothesized and non-unique conceptualization of the subsurface hydrogeology and flow system, generally replicated measured effluent constituent

  4. Decision no 2009-DC-0157 of the 15. of September 2009 by the Nuclear Safety Authority specifying the limits of releases in the environment of liquid and gaseous effluents of the base nuclear installation n. 29 operated by the CIS Bio International on the district of Saclay (Essonne department)

    International Nuclear Information System (INIS)

    2009-01-01

    This document contains references to the different legal and official documents (codes, orders, minister's opinion, public surveys, administrative authorizations, local community opinion) at the root of this specification of limits related to releases in the environment of liquid and gaseous effluents of a base nuclear installation. Tables present the limits for radioactive liquid effluents (iodine, rare earths, and other beta and gamma emitters) and the maximum admitted concentrations for gaseous chemical effluents (SO 2 , H 2 S, VOCs)

  5. Active liquid treatment by a combination of precipitation and membrane processes

    International Nuclear Information System (INIS)

    Gutman, R.G.; Cumming, I.W.; Williams, G.H.

    1986-08-01

    New ultrafiltration processes developed for the treatment of low and medium active radioactive wastes, were applied successfully to a variety of simulated and real wastes, including magnesium alloy clad spent storage fuel pond waters, reprocessing plant solvent wash liquors, plutonium production effluents and mixed site effluents. After initial laboratory scale feasibility experiments the process was scaled up successfully, using a variety of different ultrafiltration modules. The information accumulated on membrane performance, membrane fouling and flux restoration techniques, and ancillary equipment performance was used to design a much larger demonstration pilot plant. This plant has been constructed and is now processing continuously each day over 1m 3 of a real radioactive effluent. (author)

  6. Palisades Nuclear Plant. Radioactive effluents and environmental monitoring sections to second annual operating report

    International Nuclear Information System (INIS)

    1977-01-01

    A total of 0.435 Ci of radioactive liquid effluent less tritium was released with 19.63 Ci of tritium. Both liquid and gaseous releases were within permissible limits. There were 8 Ci of solid wastes stored on the site as of 12/31/76. Data clearly shows there was no detectable increase in radioactivity levels in the environmental media that can be attributed to plant effluents. Monitoring reports are presented concerning fish, meteorology, noise, and cooling tower drift

  7. Quantification of effluents in the production of nuclear fuel

    Energy Technology Data Exchange (ETDEWEB)

    Sakai, Mayara C.C.B.; Riella, Humberto G.; Carvalho, Elita F.U. de, E-mail: mcostac@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-07-01

    At the Instituto de Pesquisa Energéticas e Nucleares (IPEN), the Centro de Combustível Nuclear (CCN), Sao Paulo, SP, Brazil, is responsible for manufacturing fuels for the IEA-R1 reactor and, possibly, the multipurpose reactor fuels. In order to meet the demand for both reactors, the CCN developed a new plant. The production process of the fuel generates several types of effluents - containing uranium or not - being solid, liquid and gaseous with varied physical and chemical characteristics. The objective of this work is to follow the nuclear fuel production process and to identify, quantify and characterize the effluents, especially the liquid ones, to later elaborate a plan of management of these and eventually dispose in a responsible way in the environment. (author)

  8. Quantification of effluents in the production of nuclear fuel

    International Nuclear Information System (INIS)

    Sakai, Mayara C.C.B.; Riella, Humberto G.; Carvalho, Elita F.U. de

    2017-01-01

    At the Instituto de Pesquisa Energéticas e Nucleares (IPEN), the Centro de Combustível Nuclear (CCN), Sao Paulo, SP, Brazil, is responsible for manufacturing fuels for the IEA-R1 reactor and, possibly, the multipurpose reactor fuels. In order to meet the demand for both reactors, the CCN developed a new plant. The production process of the fuel generates several types of effluents - containing uranium or not - being solid, liquid and gaseous with varied physical and chemical characteristics. The objective of this work is to follow the nuclear fuel production process and to identify, quantify and characterize the effluents, especially the liquid ones, to later elaborate a plan of management of these and eventually dispose in a responsible way in the environment. (author)

  9. Radionuclide content of wastewater and solid waste from a low-level effluent treatment plant

    International Nuclear Information System (INIS)

    Muhamat Omar; Zalina Laili; Nik Marzukee Nik Ibrahim; Mat Bakar Mahusin

    2010-01-01

    A study on radioactivity levels of wastewater and solid waste from a Low-level Effluent Treatment Plant has been carried out. The measurement of radionuclide concentration was carried out using gamma spectrometry. Natural and anthropogenic radionuclides were detected in solid radioactive waste recovered from the treatment plant. The presence of radionuclides in waste water varies depending on activities carried out in laboratories and facilities connected to the plant. (author)

  10. Treatment of dairy effluent model solutions by nanofiltration and reverse osmosis

    Directory of Open Access Journals (Sweden)

    I. Kyrychuk

    2015-05-01

    Full Text Available Introduction. Dairy industry generates a large amount of wastewaters that have high concentrations and contain milk components. Membrane processes have been shown to be convenient for wastewater treatment recovering milk components present in wastewaters and producing treated water. Materials and methods. The experiments were carried out in an unstirred batch sell using nanofiltration membranes OPMN-P (ZAO STC “Vladipor”, Russian Federation and reverse osmosis membranes NanoRo, ZAO (“RM Nanotech”, Russian Federation. The model solutions of dairy effluents –diluted skim and whole milk were used. Results. The nanofiltration and reverse osmosis membranes showed the same permeate flux during the concentration of model solutions of dairy effluents. The reason of this was likely membrane fouling with feed components. The fouling indexes indicated the fouling factor that was higher for RO. The higher permeate quality was obtainedwith RO membranes. The NF permeate containing up to 0.4 g/L of lactose and 0.75 g/L of mineral salts can be discharged or after finishing trеatment (e.g. RO or other can be reused. The obtained NF and RO retentate corresponds to milk in composition and can be used for non-food applications or as feed supplement for animals. Conclusions.The studied RO and NF membranes can be used for concentration of dairy effluents at low pressure. They showed better performance and separation characteristics comparing with data of other membranes available in the literature.

  11. Structural modeling and analysis of an effluent treatment process for electroplating--a graph theoretic approach.

    Science.gov (United States)

    Kumar, Abhishek; Clement, Shibu; Agrawal, V P

    2010-07-15

    An attempt is made to address a few ecological and environment issues by developing different structural models for effluent treatment system for electroplating. The effluent treatment system is defined with the help of different subsystems contributing to waste minimization. Hierarchical tree and block diagram showing all possible interactions among subsystems are proposed. These non-mathematical diagrams are converted into mathematical models for design improvement, analysis, comparison, storage retrieval and commercially off-the-shelf purchases of different subsystems. This is achieved by developing graph theoretic model, matrix models and variable permanent function model. Analysis is carried out by permanent function, hierarchical tree and block diagram methods. Storage and retrieval is done using matrix models. The methodology is illustrated with the help of an example. Benefits to the electroplaters/end user are identified. 2010 Elsevier B.V. All rights reserved.

  12. Separate treatment of hospital and urban wastewaters: A real scale comparison of effluents and their effect on microbial communities.

    Science.gov (United States)

    Chonova, Teofana; Keck, François; Labanowski, Jérôme; Montuelle, Bernard; Rimet, Frédéric; Bouchez, Agnès

    2016-01-15

    Hospital wastewaters (HWW) contain wider spectrum and higher quantity of pharmaceuticals than urban wastewaters (UWW), but they are generally discharged in sewers without pretreatment. Since traditional urban wastewater treatment plants (WWTP) are not designed to treat HWWs, treated effluents may still contain pollutants that could impair receiving aquatic environments. Hence, a better understanding of the effect of pharmaceuticals in the environment is required. Biofilms are effective "biological sensors" for assessing the environmental effects of pharmaceuticals due to their ability to respond rapidly to physical, chemical and biological fluctuations by changes in their structure and composition. This study evaluated the efficiency of biological treatment with conventional activated sludge system performed parallel on HWW and UWW. Furthermore, six successive monthly colonizations of biofilms were done on autoclaved stones, placed in grid-baskets in the hospital treated effluents (HTE) and urban treated effluents (UTE). The biomass of these biofilms as well as the structure and diversity of their bacterial communities were investigated. Results showed better treatment efficiency for phosphate and nitrite/nitrate during the treatment of UWW. Pharmaceuticals from all investigated therapeutic classes (beta-blockers, nonsteroidal anti-inflammatory drugs, antibiotics, analgesics and anticonvulsants) were efficiently removed, except for carbamazepine. The removal efficiency of the antibiotics, NSAIDs and beta-blockers was higher during the treatment of HWW. HTE and UTE shaped the bacterial communities in different ways. Higher concentrations of pharmaceuticals in the HTE caused adapted development of the microbial community, leading to less developed biomass and lower bacterial diversity. Seasonal changes in solar irradiance and temperature, caused changes in the community composition of biofilms in both effluents. According to the removal efficiency of pharmaceuticals

  13. Radioactive effluent monitoring at the Idaho National Engineering Laboratory

    International Nuclear Information System (INIS)

    Simpson, O.D.

    1975-01-01

    The Effluent and Radiation Measurements Laboratory at the Idaho National Engineering Laboratory (INEL) has recently upgraded capabilities in the field of monitoring and analysis of radioactive airborne and liquid effluents using the techniques of gamma-ray spectrometry. The techniques and equipment used include remotely-operated, computer-based Ge(Li) spectrometers which obtain data on a real-time basis. Permanent record files are maintained of both the effluent release values and the gamma-ray data from which the release values are calculated. Should values for release levels ever be challenged, the gamma-ray spectral information for any measurement can be recalled and analyzed as needed. Daily effluent release reports are provided to operating personnel which contributes to prompt correction of any operational problems. Monthly, quarterly, and annual reports are compiled which provide inventories of the radionuclides released. A description of the effluent monitoring, reporting and records system developed at INEL for this application will be presented

  14. Healthcare liquid waste management.

    Science.gov (United States)

    Sharma, D R; Pradhan, B; Pathak, R P; Shrestha, S C

    2010-04-01

    The management of healthcare liquid waste is an overlooked problem in Nepal with stern repercussions in terms of damaging the environment and affecting the health of people. This study was carried out to explore the healthcare liquid waste management practices in Kathmandu based central hospitals of Nepal. A descriptive prospective study was conducted in 10 central hospitals of Kathmandu during the period of May to December 2008. Primary data were collected through interview, observation and microbiology laboratory works and secondary data were collected by records review. For microbiological laboratory works,waste water specimens cultured for the enumeration of total viable counts using standard protocols. Evidence of waste management guidelines and committees for the management of healthcare liquid wastes could not be found in any of the studied hospitals. Similarly, total viable counts heavily exceeded the standard heterotrophic plate count (p=0.000) with no significant difference in such counts in hospitals with and without treatment plants (p=0.232). Healthcare liquid waste management practice was not found to be satisfactory. Installation of effluent treatment plants and the development of standards for environmental indicators with effective monitoring, evaluation and strict control via relevant legal frameworks were realized.

  15. Impact evaluation of the liquid effluent disposal of the Duque de Caxias Refinery (REDUC) in fluvial waters and sediments, RJ, Brazil; Avaliacao do impacto do descarte de efluentes liquidos da Refinaria Duque de Caxias (REDUC) sobre aguas e sedimentos fluviais, RJ, Brasil

    Energy Technology Data Exchange (ETDEWEB)

    Bidone, Edison Dausacker; Santelli, Ricardo Erthal; Cordeiro, Renato Campello [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil); Gamboa, Carla Maria; Camaz, Fernando Ribeiro; Jorge, Fabricio Goncalves [PETROBRAS/REDUC, Rio de Janeiro, RJ, RJ (Brazil). Refinaria de Duque de Caxias; Carvalho, Maria de Fatima B. [PETROBRAS S.A., Rio de Janeiro, RJ (Brazil). Centro de Pesquisas (CENPES)

    2008-07-01

    The purpose of this work is to assess the contribution of the liquid effluents of the Duque de Caxias Refinery (REDUC) in the water and sediment contamination in the estuarine Iguacu-Sarapui system, a tributary of the Guanabara Bay, Rio de Janeiro, Brazil. Since 2002 is being conducted a quarterly monitoring of some parameters in water, river sediments and treated liquid effluent, such as: pH, suspended solids, total sedimented solids, dissolved oxygen, biochemical oxygen demand, chemical oxygen demand, total organic carbon, oil and grease (O and G), phenols, sulfide, ammonia, metals and metalloids (V, Cr, Pb, Ni, Cu, Cd, Zn, Hg, As, Se , Co, Fe, Mn), polycyclic aromatic hydrocarbons, coprostanol and cholesterol (indicators of domestic wastes). The obtained results show that the effluents meet the legal standards and the treated liquid effluents from REDUC in the estuarine system have little or no impact on river water quality. The higher levels of contaminants detected in water and sediments samples are directly related to untreated domestic sewage from urban areas. (author)

  16. Human infective potential of Cryptosporidium spp., Giardia duodenalis and Enterocytozoon bieneusi in urban wastewater treatment plant effluents

    Data.gov (United States)

    U.S. Environmental Protection Agency — Cryptosporidiosis, giardiasis, and microsporidiosis are important waterborne diseases. In the standard for wastewater treatment plant (WWTP) effluents in China and...

  17. Treatment options of low level liquid waste of ETP origin by synthetic zeolites

    International Nuclear Information System (INIS)

    Singh, I.J.; Jain, Savita; Sathi Sasidharan, N.; Deshingkar, D.S.

    2001-08-01

    Mixture of synthetic zeolites, AR1, 4A and 13X of Indian origin were tested in a single fixed bed column operation for the treatment of low level liquid waste received at Effluents Treatment Plant (ETP) Trombay, under dynamic conditions. The mixed bed of zeolites was highly effective in decontaminating thousands of bed volumes of waste stream from radio cesium, radio strontium and gross beta gamma activity. High volume reduction factors, upwards of 10,000 are available in this process compared to less than 100 available with chemical precipitation process, currently followed. Containment of entrapped activity in zeolite bed was studied by solidifying them in Portland cement matrix as stable waste form. Incorporation of minerals like vermiculite as minor additive for improving the leaching characteristics of the final waste form was evaluated. Zeolite incorporated cement blocks were subjected to leach tests in distilled water for over 200 days to assess the incremental and cumulative leach rates of individual activity components. Leachability index of radio cesium and strontium were computed, which indicated the suitability of the matrix for safe shallow land burial. (author)

  18. CY-1981 effluent monitoring report

    International Nuclear Information System (INIS)

    Honkus, R.J.

    1982-05-01

    The effluent monitoring programs at ICPP for calendar year 1981 are summarized. During the year, five significant occurrences or unplanned releases occurred. These are briefly described and tabulated. In none of the instances were the applicable Radiation Concentration Guides (RCG's) exceeded. A graphic summary of the total airborne, liquid and solid releases during CY-1981 is presented. Liquid waste activity was higher than anticipated due to various processing factors throughout the year. Solid waste jumped dramatically in December due to shipment of end-prices from the EBR-II fuel which was processed during the Electrolytic campaign

  19. Effect of the tide on the diffusion of 3H in the liquid effluent discharged from Daya Bay Nuclear Power Station

    International Nuclear Information System (INIS)

    Zhang Jie; Zhang Chunlin; Pan Meng

    2006-01-01

    The tide field at the time of liquid effluent discharging from Daya Bay nuclear power station, and the average water speed at the monitoring points in west Daya Bay from the time of discharging to the time of sampling were calculated by ADI (Alternating Direction Implicit) method. By comparing analysis, the difference of 3 H diffusion between spring tide and neap tide (the expansion of 3 H within one day of spring tide is greater than that within one day of neap tide) was found. So, an equivalent diffusion time is introduced to modify the original model, and a better attenuation relation between the average 3 He concentration in west Daya Bay and the time since the liquid 3 H discharging is obtained. (authors)

  20. An Evaluation of Illicit Stimulants and Metabolites in Wastewa ter Effluent and the Wisconsin River Along the Central Wisconsin River Basin

    Directory of Open Access Journals (Sweden)

    Erik S. Hendrickson

    2015-09-01

    Full Text Available The goals of the study were to develop a method for extracting and quantifying illicit stimulants and metabolites, methamphetamine, amphetamine, cocaine, and benzoylecogonine from wastewater effluent and surface water grab samples, and evaluate Central Wisconsin wastewater treatment plant’s (WWTP removal efficiency of compounds of interest. The method created used HLB solid-phase extraction (SPE cartridges to extract substances of interest and High Performance Liquid Chromatography tandem Mass Spectrometry (HPLC/MS/MS for quantification and qualification. All four wastewater effluent samples and three Wisconsin River samples had quantifiable concentrations of at least one analyte. Conclusions derived from the study were: The method created is effective for separating, quantifying, and identifying amphetamine, cocaine, and benzoylecognine from wastewater effluent and surface water grab samples, and each illicit stimulant and metabolite analyzed in this study were all quantified in wastewater effluent, indicating these compounds have the ability to survive WWTP.

  1. A database system for the control of radioactive effluents generated by the IPEN-CNEN/SP installations

    International Nuclear Information System (INIS)

    Maduar, M.F.

    1992-01-01

    A PC-compatible database system has been developed in order to optimize the control of liquid and gaseous effluents generated by the installations of IPEN-CNEN/SP. The system implements source-term generation, optimizes the discharge control of the effluents and allows several ways for the retrieval of data concerning to the effluents. (author)

  2. Treatment and Energy Valorisation of an Agro-Industrial Effluent in Upflow Anaerobic Sludge Reactor (UASB)

    Science.gov (United States)

    Martins, Ramiro; Boaventura, Rui; Paulista, Larissa

    2017-12-01

    The accelerated growth of the population brings with it an increase in the generation of agro-industrial effluents. The inadequate discharge of these effluents significantly affects the quality of water resources. In this way, it becomes important to invest in treatment processes for agro-industrial effluents, particularly low-cost ones. In this context, the present study includes the design and construction of an UASB reactor and optimization of the anaerobic digestion treatment of the raw effluent from sweet chestnut production in the agro-industrial company Sortegel. The efficiency of the system was evaluated through the determination / monitoring of oxygen chemical oxygen demand (COD), biochemical oxygen demand (BOD5), total suspended solids (TSS), biogas production rate and quality (% methane). The reactor was fed for 25 weeks and operated under mesophilic conditions (temperature 30-40 °C). Different values were tested for the hydraulic retention time (HRT) and volumetric flow rate (VF): 0.66 days (VF=1509 L.m-3.d-1); 1.33 days (VF=755 L.m-3.d-1); 2.41 d days (VF=415 L.m-3.d-1). The average COD removal efficiency reached values of 69%, 82% and 75%, respectively, and simultaneously the associated BOD5 removal efficiency was 84%, 91% and 70%. As regards TSS, removal values were 78%, 94% and 63%. In addition, high methane production rates were obtained, between 2500 and 4800 L CH4.kg-1 COD removed d-1. For all the hydraulic retention times tested, high concentrations of methane in the biogas were recorded: 66-75%, 70% and 75% for HRT of 0.66, 1.33 and 2.41 days, respectively.

  3. F/H Effluent Treatment Facility. Preliminary engineering report

    International Nuclear Information System (INIS)

    1985-01-01

    The Department of Energy is currently proposing to construct the F/H ETF to process wastewater from the Separations Areas and replace the existing seepage basins. Reasons for seepage basin closure are two-fold. First, nonradioactive hazardous materials routinely discharged to the seepage basins may have adversely impacted the quality of the groundwater in the vicinity of the basins. Second, amendments to the Resource Conservation and Recovery Act (RCRA) were approved in 1984, prohibiting the discharge of hazardous wastes to unlined seepage basins after November, 1988. The F/H ETF will consist of wastewater storage facilities and a treatment plant discharging treated effluent to Upper Three Runs Creek. Seepage basin use in F and H Areas wil be discontinued after startup, allowing timely closure of these basins. 3 refs

  4. 200 Area TEDF effluent sampling and analysis plan

    International Nuclear Information System (INIS)

    Alaconis, W.C.; Ballantyne, N.A.; Boom, R.J.

    1995-06-01

    This sampling analysis sets forth the effluent sampling requirements, analytical methods, statistical analyses, and reporting requirements to satisfy the State Waste Discharge Permit No. ST4502 for the Treated Effluent Disposal Facility. These requirements are listed below: Determine the variability in the effluent of all constituents for which enforcement limits, early warning values and monitoring requirements; demonstrate compliance with the permit; and verify that BAT/AKART (Best Available Technology/All know and Reasonable Treatment) source, treatment, and technology controls are being met

  5. Decentralised wastewater treatment effluent fertigation: preliminary ...

    African Journals Online (AJOL)

    2018-04-02

    Apr 2, 2018 ... The experimental site at Newlands-Mashu Research Facility, located in Durban ... Samples of effluent used during the study were collected from the AF ... Yield parameters of banana (number and mass of true fingers ..... GHOREISHI M, HOSSINI Y and MAFTOON M (2012) Simple models for predicting leaf ...

  6. Study on quality of effluent discharge by the Tiruppur textile dyeing units and its impact on river Noyyal, Tamil Nadu (India).

    Science.gov (United States)

    Rajkumar, A Samuel; Nagan, S

    2010-10-01

    In Tiruppur, 729 textile dyeing units are under operation and these units generate 96.1 MLD of wastewater. The untreated effluent was discharged into the Noyyal River till 1997. After the issuance of directions by Tamil Nadu Pollution Control Board (TNPCB) in 1997, these units have installed 8 common effluent treatment plants (CETP) consisting of physical, chemical and biological treatment units. Some of the units have installed individual ETP (IETP). The treated effluent was finally discharged into the river. The dyeing units use sodium chloride in the dyeing process for efficient fixing of dye in the fabric efficiently. This contributes high total dissolved solids (TDS) and chlorides in the effluent. CETPs and IETPs failed to meet discharge standards of TDS and chlorides and thereby significantly affected the river water quality. TDS level in the river water was in the range of 900 - 6600 mg/L, and chloride was in the range of 230 - 2700 mg/L. Orathupalayam dam is located across Noyyal river at 32 km down stream of Tiruppur. The pollutants carried by the river were accumulated in the dam. TDS in the dam water was in the range of 4250 - 7900 mg/L and chloride was in the range of 1600 - 2700 mg/L. The dam sediments contain heavy metals of chromium, copper, zinc and lead. In 2006, the High Court has directed the dyeing units to install zero liquid discharge (ZLD) plant and to stop discharging of effluent into the river. Accordingly, the industries have installed and commissioned the ZLD plant consisting of RO plant and reject management system in 2010. The effluent after secondary treatment from the CETP is further treated in RO plant. The RO permeate is reused by the member units. The RO reject is concentrated in multiple effect evaporator (MEE)/ mechanical vacuum re-compressor (MVR). The concentrate is crystallized and centrifuged to recover salt. The salt recovered is reused. The liquid separated from the centrifuge is sent to solar evaporation pan. The salt

  7. Toxicity Identification and Evaluation for the Effluent from Wastewater Treatment Plant in Industrial Complex using D.magna

    Science.gov (United States)

    Lee, S.; Keum, H.; Chun Sang, H.

    2015-12-01

    In recent years, the interests on the impacts of industrial wastewater on aquatic ecosystem have increased with concern about ecosystem protection and human health. Whole effluent toxicity tests are used to monitor toxicity by unknown toxic chemicals as well as conventional pollutants from industrial effluent discharges. This study describes the application of TIE (toxicity identification evaluation) procedures to an acutely toxic effluent from a wastewater treatment plant in industrial complex which was toxic to Daphnia magna. In TIE phase I (characterization step), the toxic effects by heavy metals, organic compounds, oxidants, volatile organic compounds, suspended solids and ammonia were screened and revealed that the source of toxicity is far from these toxicants group. Chemical analysis (TIE phase II) on TDS showed that the concentration of chloride ion (6,900 mg/L) was substantially higher than that predicted from EC50 for D. magna. In confirmation step (TIE phase III), chloride ion was demonstrated to be main toxicant in this effluent by the spiking approach, species sensitivity approach and deletion approach. Calcium, potassium, magnesium, sodium, fluorine, sulfate ion concentration (450, 100, 80, 5,300, 0.66, 2,200mg/L) was not shown toxicity from D. magna. Finally, we concluded that chloride was the most contributing toxicant in the waste water treatment plant. Further research activities are needed for technical support of toxicity identification and evaluation on the various types of wastewater treatment plant discharge in Korea. Keywords : TIE, D. magna, Industrial waste water Acknowledgement This research was supported by a grant (15IFIP-B089908-02) from Plant Research Program funded by Ministry of Land, Infrastructure and Transport of Korean government

  8. Toxicity evaluation of the process effluent streams of a petrochemical industry.

    Science.gov (United States)

    Reis, J L R; Dezotti, M; Sant'Anna, G L

    2007-02-01

    The physico-chemical characteristics and the acute toxicity of several wastewater streams, generated in the industrial production of synthetic rubber, were determined. The acute toxicity was evaluated in bioassays using different organisms: Danio rerio (fish), Lactuca sativa (lettuce) and Brachionus calyciflorus (rotifer). The removal of toxicity attained in the industrial wastewater treatment plant was also determined upstream and downstream of the activated sludge process. The results obtained indicate that the critical streams in terms of acute toxicity are the effluents from the liquid polymer unit and the spent caustic butadiene washing stage. The biological treatment was able to partially remove the toxicity of the industrial wastewater. However, a residual toxicity level persisted in the biotreated wastewater. The results obtained with Lactuca sativa showed a high degree of reproducibility, using root length or germination index as evaluation parameters. The effect of volatile pollutants on the toxicity results obtained with lettuce seeds was assessed, using ethanol as a model compound. Modifications on the assay procedure were proposed. A strong correlation between the toxic responses of Lactuca sativa and Danio rerio was observed for most industrial effluent streams.

  9. Disposal of the radioactive effluents at the 'Commissariat a l'Energie Atomique'. Treatment leading to evacuation into a river; Probleme du rejet des residus radioactifs liquides au CEA. Traitements aboutissant a des rejets en riviere

    Energy Technology Data Exchange (ETDEWEB)

    Duhamel; Menoux; Candillon [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    The problems dealing with the treatment of the radioactive effluents at the 'Commissariat a l'Energie Atomique' have been studied in order to allow evacuation into a river - after treatment - with respect for the standards regarding radiation protection. 2) At Saclay where there is no possibility of evacuating the effluents, the liquids are directed towards Fontenay-aux-Roses by means of tank wagons. They are removed temporarily into the sewers and will be evacuated later on into the Seine. 3) ln Le Bouchet, the effluents coming from the Factory where urano-thorianite ore is treated will undergo a two stages treatment. The elimination of radium in the first phase facilitates decontamination in the second phase. 4) In Marcoule: a study of synthetic effluents of the Marcoule type is being carried on in order to perfect a selective elimination method of Sr{sup 90} and Cs{sup 137} by coprecipitation. 5) In the general case of the final evacuation into a river, the following problems have been studied: - pre-dilution of treated waters between the storing tanks and the river; - admission in the river; dilution in the river (preliminary study by means of a tracer); - evolution of the activity in the water of the river (adsorption by inert or living elements), contamination of the banks; - locating of the site; - isotopic dilution. 6) Circumstantial study of that last problem. 7) The quantity of a given product in water conditions the isotopic dilution of its radioactive isotopes. When the analysis shows the lack of an element, stable isotopes should be added in order to compensate it. 8) That method led to difficult analysis (specially as far as Sr{sup 90} is concerned), for the percentage of stable isotopes necessary to an important isotopic dilution is very low. 9) The standard regarding the quantity of Sr{sup 90} in drinking water is 8.10{sup -8} c/m{sup 3} or 4.10{sup -10} g/m{sup 3}. So a percentage of 40 {mu}g/litre of Sr is enough which is difficult

  10. Use of macrophites for removal of Co e Zn in liquid effluents

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Juliana de Almeida S.; Silva, Paulo Sergio Cardoso da Silva, E-mail: ju_aso@usp.br, E-mail: pscsilva@ipen.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil)

    2017-07-01

    This study proposes the application of Eichhornia crassipes roots biomass to remove cobalt and zinc ions from solution, aiming its application to effluent treatment. The efficiency of adsorption and the percent of removal were checked as a function of pH and contact time. The plants, for biomass production, were collected at the Billings reservoir in São Bernardo do Campo, located in the Southeast of São Paulo Metropolitan Region. The biomass obtained was subjected to the chemical activation process by the treatment with HCl 0.1 molL{sup -1} in order to increase its surface area. The concentrations of cobalt and zinc, present in the adsorbent, before and after the adsorption experiments were determined by the instrumental neutron activation analysis (INAA) technique. Results showed that the pH of the solution must be adjusted after the addition of the biomass. The contact time for maximum removal of both ions is between 20 and 30 min. (author)

  11. Technical Orders of 10 August 1976 on the limits and procedures applicable to radioactive effluent discharges from nuclear installations

    International Nuclear Information System (INIS)

    1976-01-01

    Seven technical Orders by the competent Ministers (mainly the Ministers of Health, of Industry and Research, of the Quality of Life) lay down the procedures, conditions and limits applicable to gaseous and liquid radioactive effluent discharges from nuclear installations. These Orders of 10 August were published on 12 September 1976 in the Official French Gazette and were made in implementation of the Decree of 6 November 1974 on gaseous radioactive effluent discharges from nuclear installations and the Decree of 31 December 1974 on liquid radioactive effluent discharges from nuclear installations. Apart from the general rules for setting limits and methods for effluent discharges, they specify the measures for environmental monitoring and for control by the Central Service for Protection against Ionizing Radiations. Certain of them contain the general rules for liquid or gaseous effluent discharges from all nuclear installations, while others lay down the rules proper to light water nuclear power plants. Other types of reactor ie. fast breeders are not yet subject to such regulations. (N.E.A.) [fr

  12. Design Seminar for Land Treatment of Municipal Wastewater Effluents.

    Science.gov (United States)

    Demirjian, Y. A.

    This document reports the development and operation of a country-wide wastewater treatment program. The program was designed to treat liquid wastewater by biological treatment in aerated lagoons, store it, and then spray irrigate on crop farmland during the growing season. The text discusses the physical design of the system, agricultural aspects,…

  13. Effect of soap industry effluents on soil and ground water in Albageir area

    International Nuclear Information System (INIS)

    Awadalla, S. O.

    2004-02-01

    This study investigates the effect on soil and ground water produced by the effluent from soap industry discharged from Alsheikh Mustafa Alamin (SMA) factory, in Albageir industrial area, located 45 Km south of Khartoum. Soil samples were taken from the periphery of the effluent pond and from 25 and 50 cm depths from pits at different distances from the pond.The samples were analyzed for the following chemical and physical characteristics PH, EC, sodium, chloride ions and their grain size, in order to investigate any possible soil degradation. The results showed that there is an increase in soil salinity and sodicity resulting from the improper discharge of the liquid waste, and from lack of treatment before the discharge. Hence, there are definitive signs for soil degradation in the study area, which could reach a high magnitude in the long.This situation could be rectified by adopting updated techniques for treatment and disposal of effluent, and by regular inspection, by the authorities in order to make sure that the regulations are not violated. Chemical and physical analyses of ground water samples showed no signs of pollution. However, if the disposal practices are not revised, the possibility of pollution in the near future is likely to occur. A package of measurements is proposed in order to curb the impact of the industry on the environment. (Author)

  14. Facility effluent monitoring plan for the 324 Facility

    International Nuclear Information System (INIS)

    1994-11-01

    The 324 Facility [Waste Technology Engineering Laboratory] in the 300 Area primarily supports the research and development of radioactive and nonradioactive waste vitrification technologies, biological waste remediation technologies, spent nuclear fuel studies, waste mixing and transport studies, and tritium development programs. All of the above-mentioned programs deal with, and have the potential to, release hazardous and/or radioactive material. The potential for discharge would primarily result from (1) conducting research activities using the hazardous materials, (2) storing radionuclides and hazardous chemicals, and (3) waste accumulation and storage. This report summarizes the airborne and liquid effluents, and the results of the Facility Effluent Monitoring Plan (FEMP) determination for the facility. The complete monitoring plan includes characterizing effluent streams, monitoring/sampling design criteria, a description of the monitoring systems and sample analysis, and quality assurance requirements

  15. Management of Discharge of Low Level Liquid Radioactive Waste Generated in Medical, Educational, Research and Industrial Facilities

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-07-15

    Although published information on management technologies suitable for radioactive effluents is readily available, smaller facilities such as hospitals, universities and research laboratories in some countries can benefit from more detailed guidance on identifying optimal arrangements for effectively managing their radioactive liquid effluents. A wide range of circumstances exist globally, given that the generation of radioactive liquid effluents may be regular or irregular, and the liquid effluents may be suitable for direct discharge to the environment, or may require a period of decay storage prior to discharge. Countries typically fit into one of the four following categories with respect to the status of their arrangements for the management of radioactive liquid effluents: (1) The country does not have sufficient technical, regulatory and organizational infrastructure to effectively manage its radioactive liquid effluents; (2) The country's technical infrastructure for effectively managing its radioactive liquid effluents is almost sufficient, but it is not supported by an acceptable level of regulatory and organizational capacity (e.g. legal infrastructure, administrative infrastructure); (3) The country has sufficient technical, regulatory and organizational capacity, but it is known that the application of the requirements for proper management of radioactive liquid effluents is, in many cases, not being carried out to the standard indicated by official reports; (4) The country has well developed and established regulatory and organizational capacity, which is complemented by an acceptable level of relevant technical infrastructure such that the radioactive liquid effluents can be properly managed. Facilities, as well as countries, in the first three categories will find information in this publication to assist their further development. Even countries that already have the necessary infrastructure to properly manage their liquid radioactive effluents may

  16. Management of Discharge of Low Level Liquid Radioactive Waste Generated in Medical, Educational, Research and Industrial Facilities

    International Nuclear Information System (INIS)

    2013-07-01

    Although published information on management technologies suitable for radioactive effluents is readily available, smaller facilities such as hospitals, universities and research laboratories in some countries can benefit from more detailed guidance on identifying optimal arrangements for effectively managing their radioactive liquid effluents. A wide range of circumstances exist globally, given that the generation of radioactive liquid effluents may be regular or irregular, and the liquid effluents may be suitable for direct discharge to the environment, or may require a period of decay storage prior to discharge. Countries typically fit into one of the four following categories with respect to the status of their arrangements for the management of radioactive liquid effluents: (1) The country does not have sufficient technical, regulatory and organizational infrastructure to effectively manage its radioactive liquid effluents; (2) The country's technical infrastructure for effectively managing its radioactive liquid effluents is almost sufficient, but it is not supported by an acceptable level of regulatory and organizational capacity (e.g. legal infrastructure, administrative infrastructure); (3) The country has sufficient technical, regulatory and organizational capacity, but it is known that the application of the requirements for proper management of radioactive liquid effluents is, in many cases, not being carried out to the standard indicated by official reports; (4) The country has well developed and established regulatory and organizational capacity, which is complemented by an acceptable level of relevant technical infrastructure such that the radioactive liquid effluents can be properly managed. Facilities, as well as countries, in the first three categories will find information in this publication to assist their further development. Even countries that already have the necessary infrastructure to properly manage their liquid radioactive effluents may

  17. Behavior and removal of organic species in the Savannah River Plant effluent treatment facility

    International Nuclear Information System (INIS)

    Oblath, S.B.; Georgeton, G.K.

    1988-01-01

    The effluent treatment facility (ETF) at the Savannah River Plant (SRP) is a new facility designed to treat and decontaminate low-level radioactive wastewater prior to release to the environment. The wastewater is primarily composed of evaporator overheads from the chemical separations and waste handling facilities at SRP. Primarily a 2000 mg/L NaNO 3 solution, the wastewater also contains microcurie-per-liter quantities of radionuclides and milligram-per-liter concentrations of heavy metals and organic components. This paper shows a block diagram of the major process steps. The pH adjustment, filtration, mercury removal, reverse osmosis, and cation-exchange polishing steps give a significant reduction of inorganic species and radionuclide (except trittium) concentrations. The activated carbon removal step was recently added to remove organic species to ensure that the effluent discharge permit limits for oil and grease and biochemical oxygen demand are met. The concentrates and regenerates from each of the treatment steps are further concentrated by evaporation to reduce the volume sufficiently for incorporation into and disposal as a grout

  18. Utilization of vinasse effluents from an anaerobic reactor

    Energy Technology Data Exchange (ETDEWEB)

    Costa, F J.C.B.; Rocha, B B.M.; Viana, C E; Toledo, A C

    1986-01-01

    An anaerobic reactor was developed to biodigest alcohol distillery wastes. A further post-treatment of the effluent reduced the level of pollution to the point of eventually discharging into streams and rivers. The present work also analyses the use of biodigested vinasse as a source of food for fish. Very high efficiencies were obtained during primary and secondary treatment of vinasse effluent, as demonstrated by the greatly reduced organic load. The utilization of the treated effluent as a source of fish food presents an excellent alternative for the Brazilian alcohol industry. (Refs. 6).

  19. Environmental and Effluent Monitoring at ANSTO Sites, 2002-2003

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, E L; Ferris,; Markich, S J

    2004-10-01

    This report presents the results of environmental and effluent monitoring at the Lucas Heights Science and Technology Centre (LHSTC) and the National Medical Cyclotron (NMC) from January 2002 to June 2003. Potential effective dose rates to the general public from airborne discharges from the LHSTC site were less than 0.01 mSv/year, well below the 1 mSv/year dose rate limit for long term exposure that is recommended by the Australian National Occupational Health and Safety Commission. The effective dose rates to hypothetical individuals potentially exposed to radiation in routine liquid effluent discharges from the LHSTC were recently calculated to be less than 0.001 mSv/year. This is much less than dose rates estimated for members of public potentially exposed to airborne emissions. The levels of tritium detected in roundwater and stormwater at the LHSTC were less than the Australian drinking water guidelines. The airborne and liquid effluent emissions from the NMC were below the ARPANSA-approved notification levels and NSW EPA limits, respectively. ANSTO's routine operations at the LHSTC and the NMC make only a very small addition to the natural background radiation dose experienced by members of the Australian public. (authors)

  20. Impact of effluent organic matter on low-pressure membrane fouling in tertiary treatment

    KAUST Repository

    Ayache, C.; Pidou, Marc; Croue, Jean-Philippe; Labanowski, Jé rô me; Poussade, Yvan; Tazi-Pain, Annie; Keller, Jurg R.; Gernjak, Wolfgang

    2013-01-01

    This study aims at comparing low-pressure membrane fouling obtained with two different secondary effluents at bench and pilot-scale based on the determination of two fouling indices: the total fouling index (TFI) and the hydraulically irreversible fouling index (HIFI). The main objective was to investigate if simpler and less costly bench-scale experimentation can substitute for pilot-scale trials when assessing the fouling potential of secondary effluent in large scale membrane filtration plants producing recycled water. Absolute values for specific flux and total fouling index for the bench-scale system were higher than those determined from pilot-scale, nevertheless a statistically significant correlation (r2 = 0.63, α = 0.1) was obtained for the total fouling index at both scales. On the contrary no such correlation was found for the hydraulically irreversible fouling index. Advanced water characterization tools such as excitation-emission matrix fluorescence spectroscopy (EEM) and liquid chromatography with organic carbon detection (LC-OCD) were used for the characterization of foulants. On the basis of statistical analysis, biopolymers and humic substances were found to be the major contribution to total fouling (r2 = 0.95 and r2 = 0.88, respectively). Adsorption of the low molecular weight neutral compounds to the membrane was attributed to hydraulically irreversible fouling (r2 = 0.67). © 2013 Elsevier Ltd.

  1. Impact of effluent organic matter on low-pressure membrane fouling in tertiary treatment

    KAUST Repository

    Ayache, C.

    2013-05-01

    This study aims at comparing low-pressure membrane fouling obtained with two different secondary effluents at bench and pilot-scale based on the determination of two fouling indices: the total fouling index (TFI) and the hydraulically irreversible fouling index (HIFI). The main objective was to investigate if simpler and less costly bench-scale experimentation can substitute for pilot-scale trials when assessing the fouling potential of secondary effluent in large scale membrane filtration plants producing recycled water. Absolute values for specific flux and total fouling index for the bench-scale system were higher than those determined from pilot-scale, nevertheless a statistically significant correlation (r2 = 0.63, α = 0.1) was obtained for the total fouling index at both scales. On the contrary no such correlation was found for the hydraulically irreversible fouling index. Advanced water characterization tools such as excitation-emission matrix fluorescence spectroscopy (EEM) and liquid chromatography with organic carbon detection (LC-OCD) were used for the characterization of foulants. On the basis of statistical analysis, biopolymers and humic substances were found to be the major contribution to total fouling (r2 = 0.95 and r2 = 0.88, respectively). Adsorption of the low molecular weight neutral compounds to the membrane was attributed to hydraulically irreversible fouling (r2 = 0.67). © 2013 Elsevier Ltd.

  2. Zero-valent iron treatment of dark brown colored coffee effluent: Contributions of a core-shell structure to pollutant removals.

    Science.gov (United States)

    Tomizawa, Mayuka; Kurosu, Shunji; Kobayashi, Maki; Kawase, Yoshinori

    2016-12-01

    The decolorization and total organic carbon (TOC) removal of dark brown colored coffee effluent by zero-valent iron (ZVI) have been systematically examined with solution pH of 3.0, 4.0, 6.0 and 8.0 under oxic and anoxic conditions. The optimal decolorization and TOC removal were obtained at pH 8.0 with oxic condition. The maximum efficiencies of decolorization and TOC removal were 92.6 and 60.2%, respectively. ZVI presented potential properties for pollutant removal at nearly neutral pH because of its core-shell structure in which shell or iron oxide/hydroxide layer on ZVI surface dominated the decolorization and TOC removal of coffee effluent. To elucidate the contribution of the core-shell structure to removals of color and TOC at the optimal condition, the characterization of ZVI surface by scanning electron microscopy (SEM) with an energy dispersive X-ray spectroscope (EDS), X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS) was conducted. It was confirmed that the core-shell structure was formed and the shell on ZVI particulate surface and the precipitates formed during the course of ZVI treatment consisted of iron oxides and hydroxides. They were significantly responsible for decolorization and TOC removal of coffee effluent via adsorption to shell on ZVI surface and inclusion into the precipitates rather than the oxidative degradation by OH radicals and the reduction by emitted electrons. The presence of dissolved oxygen (DO) enhanced the formation of the core-shell structure and as a result improved the efficiency of ZVI treatment for the removal of colored components in coffee effluents. ZVI was found to be an efficient material toward the treatment of coffee effluents. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. A mesocosm approach for detecting stream invertebrate community responses to treated wastewater effluent

    International Nuclear Information System (INIS)

    Grantham, Theodore E.; Cañedo-Argüelles, Miguel; Perrée, Isabelle; Rieradevall, Maria; Prat, Narcís

    2012-01-01

    The discharge of wastewater from sewage treatment plants is one of the most common forms of pollution to river ecosystems, yet the effects on aquatic invertebrate assemblages have not been investigated in a controlled experimental setting. Here, we use a mesocosm approach to evaluate community responses to exposure to different concentrations of treated wastewater effluents over a two week period. Multivariate analysis using Principal Response Curves indicated a clear, dose-effect response to the treatments, with significant changes in macroinvertebrate assemblages after one week when exposed to 30% effluent, and after two weeks in the 15% and 30% effluent treatments. Treatments were associated with an increase in nutrient concentrations (ammonium, sulfate, and phosphate) and reduction of dissolved oxygen. These findings indicate that exposure to wastewater effluent cause significant changes in abundance and composition of macroinvertebrate taxa and that effluent concentration as low as 5% can have detectable ecological effects. - Highlights: ► Stream invertebrate communities are altered by exposure to wastewater effluent. ► Principal Response Curves indicate a dose-effect response to effluent treatment. ► Biotic quality indices decline with increasing effluent concentration and exposure time. ► Effluent concentrations as low as 5% have detectable ecological effects. - Exposure to treated effluent in a stream mesocosm caused a dose-dependent response in the aquatic invertebrate community and led to declines in biological quality indices.

  4. Facility Effluent Monitoring Plan for the N Reactor

    International Nuclear Information System (INIS)

    Watson, D.J.; Brendel, D.F.; Shields, K.D.

    1991-11-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP- 0438. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan is the first annual report. It shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated as a minimum every three years. The primary purpose of the N Reactor Facility Effluent Monitoring Plan (FEMP), during standby, is to ensure that the radioactive effluents are properly monitored and evaluated for compliance with the applicable DOE orders and regulatory agencies at the federal, state, and local levels. A secondary purpose of the FEMP is to ensure that hazardous wastes are not released, in liquid effluents, to the environment even though the potential to do so is extremely low. The FEMP is to provide a monitoring system that collects representative samples in accordance with industry standards, performs analyses within stringent quality control (QC) requirements, and evaluates the data through the use of comparative analysis with the standards and acceptable environmental models

  5. Design of a PWR gaseous effluent treatment system combining delay-storage vessels, volume-reduction and activated-charcoal beds

    International Nuclear Information System (INIS)

    Nuyt, G.; Glibert, R.; Lahaye, J.P.

    1986-01-01

    The usual technique for the treatment of gaseous effluents is to store them in radioactive decay tanks and to carry out a range of operations such as recycling, volume-reduction and discharge. Although presenting undeniable advantages, this technique has a number of weaknesses which have become apparent with experience. This paper describes and analyses a system designed to alleviate these difficulties and to permit greater flexibility in gaseous effluent treatment, especially for power stations in the load-following mode of operation, by means of a combination of storage techniques and retention of short-lived isotopes in activated charcoal beds. The attractiveness of the proposed system is apparent from an analysis of operational, maintenance, safety and cost aspects. (author)

  6. Rapid, single-step most-probable-number method for enumerating fecal coliforms in effluents from sewage treatment plants

    Science.gov (United States)

    Munoz, E. F.; Silverman, M. P.

    1979-01-01

    A single-step most-probable-number method for determining the number of fecal coliform bacteria present in sewage treatment plant effluents is discussed. A single growth medium based on that of Reasoner et al. (1976) and consisting of 5.0 gr. proteose peptone, 3.0 gr. yeast extract, 10.0 gr. lactose, 7.5 gr. NaCl, 0.2 gr. sodium lauryl sulfate, and 0.1 gr. sodium desoxycholate per liter is used. The pH is adjusted to 6.5, and samples are incubated at 44.5 deg C. Bacterial growth is detected either by measuring the increase with time in the electrical impedance ratio between the innoculated sample vial and an uninnoculated reference vial or by visual examination for turbidity. Results obtained by the single-step method for chlorinated and unchlorinated effluent samples are in excellent agreement with those obtained by the standard method. It is suggested that in automated treatment plants impedance ratio data could be automatically matched by computer programs with the appropriate dilution factors and most probable number tables already in the computer memory, with the corresponding result displayed as fecal coliforms per 100 ml of effluent.

  7. Biological effects and bioaccumulation of steroidal and phenolic endocrine disrupting chemicals in high-back crucian carp exposed to wastewater treatment plant effluents

    International Nuclear Information System (INIS)

    Liu Jingliang; Wang Renmin; Huang Bin; Lin Chan; Zhou Jiali; Pan Xuejun

    2012-01-01

    Endocrine disrupting chemicals (EDCs) found in wastewater treatment plant (WWTP) effluents have been shown to cause adverse effects, but the uptake of EDCs from effluents (measured in fish muscle) are not known. In this study, the biological effects and bioaccumulation of steroidal and phenolic EDCs were assessed in high-back crucian carp (Carassius auratus) exposed to WWTP effluents for 141 days. Compared with fish controls caged in Dianchi Lake, a significant reduction in gonadosomatic index (GSI) and increase in hepatosomatic index (HSI) and plasma vitellogenin (VTG) levels were observed in effluent-exposed fish. The concentrations of steroids and phenols in effluent-exposed fish showed time-dependent increase during the exposure. In addition, bioconcentration factors (BCFs) for steroids and phenols were between 17 and 59 on day 141. The results confirm that steroids and phenols bioconcentrate in fish muscle and this accumulation may account for the biological effects associated with exposures to WWTP effluents. - Highlights: ► We assess the potential risk of WWTP effluents to fish. ► We investigate the biological responses of EDCs in fish exposed to effluents. ► We estimate the uptake of EDCs originating from WWTP effluents in fish. ► The bioaccumulation of EDCs may account for the biological effects of effluents. - Bioaccumulation of endocrine disrupting chemicals in WWTP effluent-exposed fish.

  8. Multiple response optimization of the coagulation process for upgrading the quality of effluent from municipal wastewater treatment plant

    Science.gov (United States)

    Li, Na; Hu, Yi; Lu, Yong-Ze; Zeng, Raymond J.; Sheng, Guo-Ping

    2016-05-01

    To meet the high quality standard of receiving water, the coagulation process using polyferric chloride (PFC) was used to further improve the water quality of effluent from wastewater treatment plants. Uniform design (UD) coupled with response surface methodology (RSM) was adopted to assess the effects of the main influence factors: coagulant dosage, pH and basicity, on the removal of total organic carbon (TOC), NH4+-N and PO43--P. A desirability function approach was used to effectively optimize the coagulation process for the comprehensive removal of TOC, NH4+-N and PO43--P to upgrade the effluent quality in practical application. The optimized operating conditions were: dosage 28 mg/L, pH 8.5 and basicity 0.001. The corresponding removal efficiencies for TOC, NH4+-N and PO43--P were 77.2%, 94.6% and 20.8%, respectively. More importantly, the effluent quality could upgrade to surface water Class V of China through coagulation under optimal region. In addition, grey relational analysis (GRA) prioritized these three factors as: pH > basicity > dosage (for TOC), basicity > dosage > pH (for NH4+-N), pH > dosage > basicity (for PO43--P), which would help identify the most important factor to control the treatment efficiency of various effluent quality indexes by PFC coagulation.

  9. Removal of radium-226 from uranium mining effluents

    International Nuclear Information System (INIS)

    Averill, D.W.; Moffett, D.; Webber, R.T.; Whittle, L.; Wood, J.A.

    1984-12-01

    Uranium mining and milling operations usually generate large quantities of solid and liquid waste materials. A slurry, consisting of waste rock and chemical solutions from the milling operation, is discharged to impoundment areas (tailings basins). Most of the radioactive material dissolved in tailings slurries is precipitated by the addition of lime and limestone prior to discharge from the mill. However, the activity of one radioisotope, radium-226, remains relatively high in the tailings basin effluents. In Canada, radium-226 is removed from uranium mining and milling effluents by the addition of barium chloride to precipitate barium-radium sulphate [(Ba,Ra)SO 4 ]. Although dissolved radium-226 activities are generally reduced effectively, the process is considered to have two undesirable characteristics: the first related to suspended radium-226 in the effluents and the second to ultimate disposal of the (Ba,Ra)SO 4 sludge. A government-industry mining task force established a radioactivity sub-group in 1974 to assist in the development of effluent guidelines and regulations for the uranium mining industry (Radioactivity Sub-group, 1974). The investigation of more effective removal methods was recommended, including the development of mechanical treatment systems as alternatives to settling ponds. Environment Canada's Wastewater Technology Centre (WTC) initiated a bench scale study in March, 1976 which was designed to assess the feasibility of using precipitation, coagulation, flocculation and sedimentation for the removal of radium-226. In 1977, the study was accelerated with financial assistance from the Atomic Energy Control Board. The results were favourable, with improved radium removals obtained in bench scale batch tests using barium chloride as the precipitant and either alum or ferric chloride as the coagulant. A more comprehensive bench scale and pilot scale process development and demonstration program was formulated. The results of the joint study

  10. Pathway-based approaches for assessment of real-time exposure to an estrogenic wastewater treatment plant effluent on fathead minnow reproduction

    Science.gov (United States)

    Cavallin, Jenna E.; Jensen, Kathleen M.; Kahl, Michael D.; Villeneuve, Daniel L.; Lee, Kathy E.; Schroeder, Anthony L.; Mayasich, Joe; Eid, Evan P.; Nelson, Krysta R.; Milsk, Rebecca Y.; Blackwell, Brett R.; Berninger, Jason P.; LaLone, Carlie A.; Blanskma, Chad; Jicha, Terri M.; Elonen, Colleen M.; Johnson, Rodney C.; Ankley, Gerald T.

    2016-01-01

    Wastewater treatment plant (WWTP) effluents are known contributors of chemical mixtures into the environment. Of particular concern are endocrine-disrupting compounds, such as estrogens, which can affect the hypothalamic-pituitary-gonadal axis function in exposed organisms. The present study examined reproductive effects in fathead minnows exposed for 21 d to a historically estrogenic WWTP effluent. Fathead minnow breeding pairs were held in control water or 1 of 3 effluent concentrations (5%, 20%, and 100%) in a novel onsite, flow-through system providing real-time exposure. The authors examined molecular and biochemical endpoints representing key events along adverse outcome pathways linking estrogen receptor activation and other molecular initiating events to reproductive impairment. In addition, the authors used chemical analysis of the effluent to construct a chemical-gene interaction network to aid in targeted gene expression analyses and identifying potentially impacted biological pathways. Cumulative fecundity was significantly reduced in fish exposed to 100% effluent but increased in those exposed to 20% effluent, the approximate dilution factor in the receiving waters. Plasma vitellogenin concentrations in males increased in a dose-dependent manner with effluent concentration; however, male fertility was not impacted. Although in vitro analyses, analytical chemistry, and biomarker responses confirmed the effluent was estrogenic, estrogen receptor agonists were unlikely the primary driver of impaired reproduction. The results provide insights into the significance of pathway-based effects with regard to predicting adverse reproductive outcomes.

  11. Treatment of uranium-containing effluent in the process of metallic uranium parts

    International Nuclear Information System (INIS)

    Yuan Guoqi

    1993-01-01

    The anion exchange method used in treatment of uranium-containing effluent in the process of metallic parts is the subject of the paper. The results of the experiments shows that the uranium concentration in created water remains is less than 10 μg/l when the waste water flowed through 10000 column volume. A small facility with column volume 150 litre was installed and 1500 m 3 of waste water can be cleaned per year. (1 tab.)

  12. 1994 Environmental monitoring drinking water and nonradiological effluent programs annual report

    International Nuclear Information System (INIS)

    Andersen, B.D.; Brock, T.A.; Meachum, T.R.

    1995-10-01

    EG ampersand G Idaho, Inc., initiated monitoring programs for drinking water in 1988 and for nonradiological parameters and pollutants in liquid effluents in 1985. These programs were initiated for the facilities operated by EG ampersand G Idaho for the US Department of Energy at the Idaho National Engineering Laboratory. On October 1, 1994, Lockheed Idaho Technologies Company (LITCO) replaced EG ampersand G Idaho as the prime contractor at the INEL and assumed responsibility for these programs. Section I discusses the general site characteristics, the analytical laboratories, and sampling methodology general to both programs. Section 2, the Drinking Water Program, tracks the bacteriological, chemical, and radiological parameters required by State and Federal regulations. This section describes the drinking water monitoring activities conducted at 17 LITCO-operated production wells and 11 distribution systems. It also contains all of the drinking water parameters detected and the regulatory limits exceeded during calendar year 1994. In addition, groundwater quality is discussed as it relates to contaminants identified at the wellhead for LITCO production wells. Section 3 discusses the nonradiological liquid effluent monitoring results for 27 liquid effluent streams. These streams are presented with emphasis on calendar year 1994 activities. All parameter measurements and concentrations were below the Resource Conservation and Recovery Act toxic characteristics limits

  13. Evaluation of genotoxicity of liquid effluents from gas washing systems by means of bioassay Trad-MCN

    International Nuclear Information System (INIS)

    Machado, Alessandra Carla Fattori Ergesse; Alves, Edenise Segala

    2007-01-01

    In the gas washing systems the gaseous emissions from a facility are forced through an absorbing liquid preventing pollutants to be dispersed into the atmosphere. In the Centro Tecnologico da Marinha em Sao Paulo/Centro Experimental Aramar (CEA), the gas washing are used to control the emissions from the uranium enrichment facilities. Uranium. fluoride, ammonia and hydrogen fluoride are the main contaminants, all heavily toxic. Biological assays, using plants or other living organisms, have been used to assess genotoxic agents in the environment. Among the bioassays using plants, the Trad-MCN has been used extensively, as it allows the evaluation of liquid or gaseous contaminants. The species Tradescantia pallida (Rose) was exposed in a dynamic system to liquid effluents from CEA. A positive control was the exposure to formaldehyde 10% in water, known as a very toxic solution, and the negative control was the exposure to filtered air. The protocol established by Ma (1983) for hybrid clones and validated for the T. pallida by Guimaraes (2003) was used to perform the Trad-MCN assays. Only preparations containing early tetrads were scored. In that context, the present study objectifies to evaluate, by the Trad-MCN bioassay, the genotoxicity of the solution from the gas washing and, also, evaluate the efficiency of that system. The results obtained show that the T. pallida is a sensitive bioindicator for the pollutants tested and can be useful for in vitro environmental monitoring under controlled conditions. (author)

  14. Evaluation of genotoxicity of liquid effluents from gas washing systems by means of bioassay Trad-MCN

    Energy Technology Data Exchange (ETDEWEB)

    Machado, Alessandra Carla Fattori Ergesse [Centro Tecnologico da Marinha em Sao Paulo (CTMSP), SP (Brazil). Div. de Monitoracao Ambiental], E-mail: alessandra@ctmsp.mar.mil.br; Alves, Edenise Segala [Instituto de Botanica de Sao Paulo, SP (Brazil). Secao de Anatomia], E-mail: ealves@ibot.sp.gov.br

    2007-07-01

    In the gas washing systems the gaseous emissions from a facility are forced through an absorbing liquid preventing pollutants to be dispersed into the atmosphere. In the Centro Tecnologico da Marinha em Sao Paulo/Centro Experimental Aramar (CEA), the gas washing are used to control the emissions from the uranium enrichment facilities. Uranium. fluoride, ammonia and hydrogen fluoride are the main contaminants, all heavily toxic. Biological assays, using plants or other living organisms, have been used to assess genotoxic agents in the environment. Among the bioassays using plants, the Trad-MCN has been used extensively, as it allows the evaluation of liquid or gaseous contaminants. The species Tradescantia pallida (Rose) was exposed in a dynamic system to liquid effluents from CEA. A positive control was the exposure to formaldehyde 10% in water, known as a very toxic solution, and the negative control was the exposure to filtered air. The protocol established by Ma (1983) for hybrid clones and validated for the T. pallida by Guimaraes (2003) was used to perform the Trad-MCN assays. Only preparations containing early tetrads were scored. In that context, the present study objectifies to evaluate, by the Trad-MCN bioassay, the genotoxicity of the solution from the gas washing and, also, evaluate the efficiency of that system. The results obtained show that the T. pallida is a sensitive bioindicator for the pollutants tested and can be useful for in vitro environmental monitoring under controlled conditions. (author)

  15. Osmosis process for leachate treatment in industrial platform: Economic and performances evaluations to zero liquid discharge.

    Science.gov (United States)

    Cingolani, Diego; Eusebi, Anna Laura; Battistoni, Paolo

    2017-12-01

    The industrial processes require large quantities of water. The presence of discharges results not only in significant environmental impact but implies wastage of water resources. This problem could be solved treating and reusing the produced wastewaters and applying the new zero liquid discharge approach. This paper discusses the design and the performances of reverse osmosis membranes for the upgrading of full scale platform for industrial liquid wastes. The final effluent from the ultrafiltration unit of the full scale plant was monitored to design the reverse osmosis unit. Previous modelling phase was used to evaluate the specific ordinary and maintenance costs and the final effluent quality (2.7 €/m 3 ). The system was designed in triple stages at different operative pressures. The economic feasibility and the payback period of the technology at different percentages of produced permeate were determined. The recovery of 90% was identified as profitable for the reverse osmosis application. One experimental pilot plant applying the reverse osmosis was used to test the final effluent. Moreover, the same flow was treated with second pilot system based on the forward osmosis process. The final efficiencies were compared. Removals higher than 95% using the reverse system were obtained for the main macropollutants and ions. No sustainable applicability of the forward osmosis was determined. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Treatment of some Textile Industrial Effluents using Dry Corn Stalk ...

    African Journals Online (AJOL)

    Corn stalk ground to various mesh sizes was used to treat textile effluents obtained from three different industries. These effluents were first pretreated with alum and then charcoal; passing the water through a column, (20cm long and 5cm diameter) containing the ground corn stalk of size diameters of 300mm, 355mm ...

  17. Treatment of septic tank effluents by a full-scale capillary seepage soil biofiltration system.

    Science.gov (United States)

    Fan, Chihhao; Chang, Fang-Chih; Ko, Chun-Han; Teng, Chia-Ji; Chang, Tzi-Chin; Sheu, Yiong-Shing

    2009-03-01

    The purpose of this study is to evaluate the efficiency of septic tank effluent treatment by an underground capillary seepage soil biofiltration system in a suburban area of Taipei, Taiwan. In contrast to traditional subsurface wastewater infiltration systems, capillary seepage soil biofiltration systems initially draw incoming influent upwards from the distribution pipe by capillary and siphonage actions, then spread influent throughout the soil biofiltration bed. The underground capillary seepage soil biofiltration system consists of a train of underground treatment units, including one wastewater distribution tank, two capillary seepage soil biofiltration units in series, and a discharge tank. Each capillary seepage soil biofiltration unit contains one facultative digestion tank and one set of biofiltration beds. At the flow rate of 50 m3/day, average influent concentrations of biochemical oxygen demand (BOD), suspended solid (SS), ammonia nitrogen (NH3-N), and total phosphates (TP), were 36.15 mg/L, 29.14 mg/L, 16.05 mg/L, and 1.75 mg/L, respectively. After 1.5 years of system operation, the measured influent and effluent results show that the treatment efficiencies of the soil biofiltration system for BOD, SS, NH3-N, TP, and total coliforms are 82.96%, 60.95%, 67.17%, 74.86%, and 99.99%, respectively.

  18. Zero effluent; Efluente zero

    Energy Technology Data Exchange (ETDEWEB)

    Monteiro, Silvio Rogerio; Santos, Angelo Francisco dos [Liquigas Distribuidora S.A., Sao Paulo, SP (Brazil)

    2008-07-01

    A scenery of water shortage and the search for profitability improvement obligate the companies to exercise their creativity and to adopt alternative methods to the conventional ones to preserve the environmental resources. The 'Effluent Zero' project comes from a paradigms changing that the environmental preservation is a necessary cost. It brings a new analysis approach of this problem with the purpose to adapt the investments and operational costs with the effluents treatment to the demands of the productive processes. In Liquigas, the project brought significant results; made a potential reduction of nearly 90% in the investments of the effluents treatment systems. That means nearly 13% in reduction in the total investments in modernization and upgrade of the existents companies installations and of 1,6% in the total operational costs of the Company. Further more, it has contributed for a reduction of until 43% of the water consumption in the bottling process of the Liquefied Petroleum Gas (LPG). This way, the project resulted in effective actions of environmental protection with relevant economic benefits. (author)

  19. Treatment of textile dyehouse effluent using ceramic membrane based process in combination with chemical pretreatment.

    Science.gov (United States)

    Bhattacharya, Priyankari; Ghosh, Sourja; Majumdar, Swachchha; Bandyopadhyay, Sibdas

    2013-10-01

    Treatment of highly concentrated dyebath effluent and comparatively dilute composite effluent having mixture of various reactive dyes collected from a cotton fabric dyeing unit was undertaken in the present study. Ceramic microfiltration membrane prepared from a cost effective composition of alumina and clay was used. Prior to microfiltration, a chemical pretreatment was carried out with aluminium sulphate in combination with a polymeric retention aid. An optimum dose of 100 mg/L of aluminium sulphate and 1 ml/L of a commercial flocculant Afilan RAMF was found effective for dye removal (> 98%) from the synthetic solutions of reactive dyes with initial concentration of 150 mg/L in both the single component and two component systems. In the microfiltration study, effect of operating pressure in the permeate flux was observed for both the pretreated and untreated effluents and permeate samples were analyzed for dye concentration, COD, turbidity, TSS, etc. during constant pressure filtration. About 98-99% removal of dyes was obtained in the combined process with COD reduction of 54-64%.

  20. Water reclamation and effluent retreatment system at Jaduguda

    Energy Technology Data Exchange (ETDEWEB)

    Beri, K K [Uranium Corporation of India Limited, Jaduguda Mines, Singhbhum (India)

    1994-06-01

    Neutralization of uranium mill tailing with lime provided in original flow sheet was not found adequate for effluent quality control within limits particularly as regards to{sup 226}Ra and Mn. The same was being controlled by dilution and hence no water was being reclaimed. In October 1987 the Jaduguda mill was expanded to augment its ore processing capacity from 1000 MT/day to 1340 MT/day. This necessitated extra water requirement, which could have been met only with water reclamation. But this would have resulted in build up of pollutant ions apart from less water available for dilution. Hence a composite scheme was made for water reclamation and treatment of effluent with BaCl{sub 2} to precipitate Ba(Ra)So{sub 4} and with lime to precipitate Mn as hydroxide. This effluent treatment plant was commissioned in May 1990 and is working satisfactorily. The scheme is being further modified and augmented to take care of Narwa mine water and sewage treatment plant effluent. (author).