WorldWideScience

Sample records for liquid control system

  1. Research of Liquid Level Control System

    Directory of Open Access Journals (Sweden)

    Dominykas Beištaras

    2015-07-01

    Full Text Available This paper presents liquid level control system model and analysis of dynamic characteristics. The system consists of scalar controlled induction motor drive, fuzzy logic controller, water tank and centrifugal pump. Simulink models of water tank, pump and controller are presented. The simulation of the system shows that the use of fuzzy logic controller reduces valve opening time and reservoir filling time.

  2. Design and Realization of Liquid Stub Tuner Control System

    Institute of Scientific and Technical Information of China (English)

    Pan Yaping(潘亚平); R. Kumazawa; T. Seki; Wang Lei(王磊); ZhaoYanping(赵燕平); Qin Chengmin(秦成明); Xue Diye(薛迪冶); Deng Xu(邓旭); Mao Yuzhou(毛玉周); Ding Jiayi(丁家义); T. Watari

    2004-01-01

    In microwave circuit and aerial system, impedance matching is very important.Liquid stub tuner is a new type of impedance matching device. In the HT-7 Tokamak Ion Cyclotron Resonance Heating ( ICRH ) system, we have already adopted liquid stub tuner to replace the conventional stub tuner. It is urgent to develop a control system of the liquid stub tuner.This paper mainly introduces the design and realization of the liquid stub tuner control system ,and briefly introduces its three controlling functions: local control, remote control and computer control.

  3. Nitrous Oxide Liquid Injection Thrust Vector Control System Testing Project

    Data.gov (United States)

    National Aeronautics and Space Administration — A Nitrous Oxide-fed Liquid Thrust Vector Control system is proposed as an efficient method for vehicle attitude control during powered flight. Pulled from a N2O main...

  4. A Smartphone Controlled Handheld Microfluidic Liquid Handling System

    CERN Document Server

    Li, Baichen; Guan, Allan; Dong, Quan; Ruan, Kangcheng; Hu, Ronggui; Li, Zhenyu

    2014-01-01

    Microfluidics and lab-on-a-chip technologies have made it possible to manipulate small volume liquids with unprecedented resolution, automation and integration. However, most current microfluidic systems still rely on bulky off-chip infrastructures such as compressed pressure sources, syringe pumps and computers to achieve complex liquid manipulation functions. Here, we present a handheld automated microfluidic liquid handling system controlled by a smartphone, which is enabled by combining elastomeric on-chip valves and a compact pneumatic system. As a demonstration, we show that the system can automatically perform all the liquid handling steps of a bead-based sandwich immunoassay on a multi-layer PDMS chip without any human intervention. The footprint of the system is 6 by 10.5 by 16.5cm, and the total weight is 829g including battery. Powered by a 12.8V 1500mAh Li battery, the system consumed 2.2W on average during the immunoassay and lasted for 8.7 hrs. This handheld microfluidic liquid handling platform...

  5. The liquid lithium limiter control system on FTU

    Energy Technology Data Exchange (ETDEWEB)

    Bertocchi, A. [EURATOM-ENEA Association, Frascati Research Center, Via E. Fermi 45, 00044 Frascati (Rome) (Italy)], E-mail: bertocchi@frascati.enea.it; Di Donna, M. [Department of Informatics, Systems and Productions, University of Rome Tor Vergata, Rome (Italy); Panella, M.; Vitale, V. [EURATOM-ENEA Association, Frascati Research Center, Via E. Fermi 45, 00044 Frascati (Rome) (Italy)

    2007-10-15

    In the second half of 2005, a liquid lithium limiter (LLL) with capillary porous system (CPS) configuration was installed to test on Tokamak FTU. The liquid lithium flows through capillaries from a reservoir to the side faced to the plasma to form a thin lithium film as wall coating. The system includes three stainless steel cases, which contain two thermocouples each one. A heating system brings the Li temperature about 200 deg. C to allow the liquid to flow. This temperature, monitored by thermocouples, needs to be controlled. To carry out this experimental procedure, some new features have been introduced in the existent control system based on Opto22{sup TM} modules and a CORBA/PHP/MySQL software architecture. The historical data storage to keep the lithium temperature evolution has been added. Two graphical tools - developed in MATLAB{sup TM} and Java environments, respectively, to monitor the lithium temperature coming from thermocouples - have been also implemented. The LLL control system allows to regulate the heater temperature in each unit to reach operational conditions, where the temperature adjustment can be performed either automatically through a specific control law or manually by the operator. During the plasma shot the system switches off the limiter power supply to prevent instruments damage. Moreover, in the same experimental context, a first approach to automatically obtain executable code - starting from control laws designed by Simulink{sup TM} tool - has been realized.

  6. Design and Experiment of Slave Computer Control System for Applying Variable-rate Liquid Fertilizer

    Institute of Scientific and Technical Information of China (English)

    Zhang Ying-zi; Chen Hai-tao; Hou Shou-yin; Ji Wen-yi; Ouyang Bin-lin; Dun Guo-qiang; Zhang Ji-cheng

    2015-01-01

    In order to increase the applying rate of liquid fertilizer and reduce environmental pollution, a slave computer control system for applying variable-rate liquid fertilizer was designed. The system used SMC as core processor and electrically controlled pressure regulator as execution component. The characteristic equation of the system was obtained by using classical control theory. Results indicated that the characteristic equation met the requirements of routh-criterion, which indicated the working process of the system was stable. Performance of the slave computer was verified via bench tests. Results demonstrated that there was no significant influence on the response from interclass error. The fertilization error was less than 0.9, and the fertilization accuracy was larger than 97%. The liquid fertilizer emitted by the fertilizing devices had no significant difference in uniformity, which met the demands of the slave computer control system for applying variable-rate liquid fertilizer.

  7. Controlling the locus of bubble nucleation by dissolved gases in heterogeneous liquid-liquid systems.

    Science.gov (United States)

    Priyananda, Pramith; Hawkett, Brian S; Warr, Gregory G

    2010-01-19

    We have examined the nucleation of chemically generated nitrogen gas bubbles in microheterogeneous systems, using optical microscopy on a model system consisting of a single liquid-liquid interface. Results clearly show that bubble nucleation occurs in both the aqueous and oil phases, despite the nitrogen production reaction being a purely aqueous phase process. A theoretical model is developed which describes the time evolution of the nitrogen concentration profile, and this reveals that bubbles in the oil are a result of homogeneous nucleation of dissolved N(2) transported across the interface into a (supersaturated) diffusion layer. We further show that bubble nucleation in the oil can be inhibited or eliminated by adding water-soluble surfactants, which facilitates aqueous phase bubble nucleation and then acts as highly effective nitrogen sinks, severely reducing the flux of dissolved gas across the water-oil interface.

  8. Automated Liquid-Level Control of a Nutrient Reservoir for a Hydroponic System

    Science.gov (United States)

    Smith, Boris; Asumadu, Johnson A.; Dogan, Numan S.

    1997-01-01

    A microprocessor-based system for control of the liquid level of a nutrient reservoir for a plant hydroponic growing system has been developed. The system uses an ultrasonic transducer to sense the liquid level or height. A National Instruments' Multifunction Analog and Digital Input/Output PC Kit includes NI-DAQ DOS/Windows driver software for an IBM 486 personal computer. A Labview Full Development system for Windows is the graphical programming system being used. The system allows liquid level control to within 0.1 cm for all levels tried between 8 and 36 cm in the hydroponic system application. The detailed algorithms have been developed and a fully automated microprocessor based nutrient replenishment system has been described for this hydroponic system.

  9. Design of Controllers for Liquid Level Control

    OpenAIRE

    Augustin Simon,; Elizabeth Varghese

    2015-01-01

    The liquid level control system is commonly used in many process control applications. The aim of the process is to keep the liquid level in the tank at the desired value. The conventional proportional-integral-derivative (PID) controller is simple, reliable and eliminates the error rate but it cannot handle complex problems. Fuzzy logic controllers are rule based systems which simulates human behavior of the process. The fuzzy controller is combined with the PID controller and th...

  10. Modal liquid crystal lens driven by low voltage produced from a wireless controlling and driving system

    Science.gov (United States)

    Zhang, Xinyu; Loktev, Mikhail; Vdovin, Gleb

    2005-04-01

    A wireless driving and controlling setup constructed by a coil system and a simple power metal-oxide-semiconductor field effect transistor switch circuit for modal liquid crystal lens has been designed, fabricated and characterized. Electrical and structural modeling and analysis have been applied to the design of the wireless power transforming and controlling system. Some key electrical characteristics of coils with different diameter and winding, such as resistance, impedance, capacitance, inductance, and Q factor, which determine the driving and controlling behaviors of the coil system constructed, are given. The liquid crystal lens can be operated under relatively low driving voltage ranging from about 1.5to12Vrms. Under dynamic operation, the prototype system has shown a stable driving and controlling performance to liquid crystal lens under the condition of switching mode of a few KHz. The possibility of integrating very small coils connected in series onto a small-size silicon chip as an integrated receiver in biomedicine application has been shown experimentally.

  11. A microprocessor-controlled tracheal insufflation-assisted total liquid ventilation system.

    Science.gov (United States)

    Parker, James Courtney; Sakla, Adel; Donovan, Francis M; Beam, David; Chekuri, Annu; Al-Khatib, Mohammad; Hamm, Charles R; Eyal, Fabien G

    2009-09-01

    A prototype time cycled, constant volume, closed circuit perfluorocarbon (PFC) total liquid ventilator system is described. The system utilizes microcontroller-driven display and master control boards, gear motor pumps, and three-way solenoid valves to direct flow. A constant tidal volume and functional residual capacity (FRC) are maintained with feedback control using end-expiratory and end-inspiratory stop-flow pressures. The system can also provide a unique continuous perfusion (bias flow, tracheal insufflation) through one lumen of a double-lumen endotracheal catheter to increase washout of dead space liquid. FRC and arterial blood gases were maintained during ventilation with Rimar 101 PFC over 2-3 h in normal piglets and piglets with simulated pulmonary edema induced by instillation of albumin solution. Addition of tracheal insufflation flow significantly improved the blood gases and enhanced clearance of instilled albumin solution during simulated edema.

  12. Design of Controllers for Liquid Level Control

    Directory of Open Access Journals (Sweden)

    Augustin Simon,

    2015-08-01

    Full Text Available The liquid level control system is commonly used in many process control applications. The aim of the process is to keep the liquid level in the tank at the desired value. The conventional proportional-integral-derivative (PID controller is simple, reliable and eliminates the error rate but it cannot handle complex problems. Fuzzy logic controllers are rule based systems which simulates human behavior of the process. The fuzzy controller is combined with the PID controller and then applied to the tank level control system. This paper proposes Inverse fuzzy with fuzzy logic controller for controlling liquid level system for a plant. This paper also compares the transient response as well as error indices of PID, Fuzzy logic controller, inverse fuzzy controllers. The responses of the controllers are verified through simulation. From the simulation results, it is observed that inverse fuzzy-PID controller gives the superior performance than the other controllers. The inverse fuzzy-PID controller gives better performance than the PID and fuzzy controller in terms of overshoot and settling time. Performance analysis is carried out with Liquid Flow Control System Design with Fuzzy logic controller. Results are evaluated by comparing the response time of conventional PID, fuzzy logic and Inverse fuzzy controller. Comparative analysis of the performance of different controllers is done in MATLAB and Simulink.

  13. Development and implementation of flowing liquid lithium limiter control system for EAST

    Energy Technology Data Exchange (ETDEWEB)

    Yuan, XiaoLin [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); University of Science and Technology of China, Hefei 230031 (China); Chen, Yue [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Hu, JianSheng, E-mail: hujs@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Li, JianGang; Zuo, GuiZhong; Ren, Jun; Zhou, Yue; Li, ChangZheng; Sun, Zheng; Xu, Wei; Meng, XianCai; Huang, Ming; Zheng, XingWei; Yao, Xingjia [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China)

    2016-11-15

    Highlights: • Development of a FLiLi remote control system for EAST. • Intelligent instruments are used to realize FLiLi remote control. • Good operating results of the control system were obtained in the EAST campaign. - Abstract: A control system of a flowing liquid lithium (FLiLi) limiter for the Experimental Advanced Superconducting Tokamak (EAST) was developed and implemented. The control system is not only able to control the direct current (DC) electromagnetic pump and heating power but can also set scanning parameters, receive the shot number, acquire the temperature, etc. The system consists of multifunctional LAN eXtensions for Instrumentation (LXI) instrument, temperature-acquisition module, programmable DC power supply, and programmable logic controller (PLC). The multi-range DC power supply is programmed to meet the operational requirements of the DC electromagnetic pump. The LXI instrument and temperature-acquisition module are used to obtain temperature data. The PLC is adopted to control the temperature of the FLiLi limiter. A safety interlock and protection function was developed for the FLiLi limiter control system. The software was designed by using LabVIEW to achieve data interaction between multiple protocols. The FLiLi limiter control system can acquire experimental data at a speed of 100 S/s and store it for later analysis. The control system was successfully applied to a FLiLi limiter to study the interaction between plasma and a fixed wall in the EAST campaign. This paper presents the framework, the implementation details, and results of the control system.

  14. Controlling micro-sized droplet generation using electrical pulses for studying liquid-liquid systems

    Science.gov (United States)

    Fernandino, M.; La Forgia, N.; Vera, A. J.; Bjerknes, J.; Dorao, C. A.

    2014-04-01

    Water droplets removal from oil is a critical process in several industries, in particular in the oil and gas industry. Water/oil separation is commonly done in large gravitational sedimentation tanks, which are over dimensioned due to the lack of accurate models to allow for optimization. This can become challenging for off-shore and subsea processing installations. One of the bottlenecks to study droplet dynamics in the micron range, is the generation of droplets with less than 100μm in diameter. In this regard, one of the most promising techniques for controlling the generated droplet size is based on the use of a high voltage electrical signal or electro-hydrodynamic technique (EHD). Although much work on EHD and droplet generation can been found in the literature, many challenges still remain. One of this is the generation of droplets smaller than 100μm in diameter in a controllable, on-demand manner. In this work, the effect of the meniscus shape and the electric pulse characteristics on the size of the generated droplet is investigated. Both the meniscus height and width help to determine the droplet size, with the latter having a stronger effect. No significant influence of the pulse amplitude and pulse width was observed for the tested conditions.

  15. Control of ROS and RNS productions in liquid in atmospheric pressure plasma-jet system

    Science.gov (United States)

    Uchida, Giichiro; Ito, Taiki; Takenaka, Kosuke; Ikeda, Junichiro; Setsuhara, Yuichi

    2016-09-01

    Non-thermal plasma jets are of current interest in biomedical applications such as wound disinfection and even treatment of cancer tumors. Beneficial therapeutic effects in medical applications are attributed to excited species of oxygen and nitrogen from air. However, to control the production of these species in the plasma jet is difficult because their production is strongly dependent on concentration of nitrogen and oxygen from ambient air into the plasma jet. In this study, we analyze the discharge characteristics and the ROS and RNS productions in liquid in low- and high-frequency plasma-jet systems. Our experiments demonstrated the marked effects of surrounding gas near the plasma jet on ROS and RNS productions in liquid. By controlling the surround gas, the O2 and N2 main plasma jets are selectively produced even in open air. We also show that the concentration ratio of NO2- to H2O2 in liquid is precisely tuned from 0 to 0.18 in deionized water by changing N2 gas ratio (N2 / (N2 +O2)) in the main discharge gas, where high NO2- ratio is obtained at N2 gas ratio at N2 / (N2 +O2) = 0 . 8 . The low-frequency plasma jet with controlled surrounding gas is an effective plasma source for ROS and RNS productions in liquid, and can be a useful tool for biomedical applications. This study was partly supported by a Grant-in-Aid for Scientific Research on Innovative Areas ``Plasma Medical Innovation'' (24108003) from the Ministry of Education, Culture, Sports, Science and Technology, Japan (MEXT).

  16. Liquid crystalline systems containing Vitamin E TPGS for the controlled transdermal nicotine delivery

    Directory of Open Access Journals (Sweden)

    Lívia Neves Borgheti-Cardoso

    Full Text Available ABSTRACT Transdermal nicotine patches have been used in smoking cessation therapy, suggested for the treatment of skin disorders with eosinophilic infiltration and have been found to improve attention performance in patients with Alzheimer's disease and age-associated memory impairment. However, skin irritation with extended patch use is still a problem. The aim of this work was to develop a simple to prepare liquid crystalline system containing vitamin E TPGS that would be able to control nicotine delivery and reduce irritation and sensitization problems. The liquid crystalline phases were macroscopically characterized by visual analysis and examined microscopically under a polarized light microscope. Topical and transdermal delivery of nicotine were investigated in vitro using porcine ear skin mounted on a Franz diffusion cell. Nicotine skin permeation from the developed cubic phase followed zero-order kinetics (r = 0.993 and was significantly enhanced after 12 h when compared to the control formulation (nicotine solution (p < 0.05 (138.86 ± 20.44 and 64.91 ± 4.06 μg/cm2, respectively. Cubic phase was also able to target viable skin layers in comparison to control solution (8.18 ± 1.89 and 2.63 ± 2.51 μg/cm2, respectively. Further studies to evaluate skin sensitization and irritation are now necessary.

  17. Hydrodynamic directional control of liquid metal droplets within a microfluidic flow focusing system

    Science.gov (United States)

    Gol, Berrak; Kurdzinski, Michael E.; Tovar-Lopez, Francisco J.; Petersen, Phred; Mitchell, Arnan; Khoshmanesh, Khashayar

    2016-04-01

    Here, we investigate the directional control of Galinstan liquid metal droplets when transferring from the high-viscosity glycerol core into the parallel low-viscosity NaOH sheath streams within a flow focusing microfluidic system. In the presence of sufficient flow mismatch between the sheath streams, the droplets are driven toward the higher velocity interface and cross the interface under the influence of surface tension gradient. A minimum flow mismatch of 125 μl/min is required to enable the continuous transfer of droplets toward the desired sheath stream. The response time of droplets, the time required to change the direction of droplet transfer, is governed by the response time of the syringe pump driven microfluidic system and is found to be 3.3 and 8.8 s when increasing and decreasing the flow rate of sheath stream, respectively.

  18. Constructing a LabVIEW-Controlled High-Performance Liquid Chromatography (HPLC) System: An Undergraduate Instrumental Methods Exercise

    Science.gov (United States)

    Smith, Eugene T.; Hill, Marc

    2011-01-01

    In this laboratory exercise, students develop a LabVIEW-controlled high-performance liquid chromatography system utilizing a data acquisition device, two pumps, a detector, and fraction collector. The programming experience involves a variety of methods for interface communication, including serial control, analog-to-digital conversion, and…

  19. Constructing a LabVIEW-Controlled High-Performance Liquid Chromatography (HPLC) System: An Undergraduate Instrumental Methods Exercise

    Science.gov (United States)

    Smith, Eugene T.; Hill, Marc

    2011-01-01

    In this laboratory exercise, students develop a LabVIEW-controlled high-performance liquid chromatography system utilizing a data acquisition device, two pumps, a detector, and fraction collector. The programming experience involves a variety of methods for interface communication, including serial control, analog-to-digital conversion, and…

  20. Post-scram Liquid Metal cooled Fast Breeder Reactor (LMFBR) heat transport system dynamics and steam generator control: Figures

    Science.gov (United States)

    Brukx, J. F. L. M.

    1982-06-01

    Dynamic modeling of LMFBR heat transport system is discussed. Uncontrolled transient behavior of individual components and of the integrated heat transport system are considered. For each component, results showing specific dynamic features of the component and/or model capability were generated. Controlled dynamic behavior for alternative steam generator control systems during forced and natural sodium coolant circulation was analyzed. Combined free and forced convection of laminar and turbulent vertical pipe flow of liquid metals was investigated.

  1. Modeling, system identification, and control for slosh-free motion of an open container of liquid

    Energy Technology Data Exchange (ETDEWEB)

    Feddema, J.; Baty, R.; Dykhuizen, R.; Dohrmann, C.; Parker, G.; Robinett, R.; Romero, V.; Schmitt, D.

    1996-04-01

    This report discusses work performed under a Cooperative Research And Development Agreement (CRADA) with Corning, Inc., to analyze and test various techniques for controlling the motion of a high speed robotic arm carrying an open container of viscous liquid, in this case, molten glass. A computer model was generated to estimate the modes of oscillation of the liquid based on the shape of the container and the viscosity of the liquid. This fluid model was experimentally verified and tuned based on experimental data from a capacitive sensor on the side of the container. A model of the robot dynamics was also developed and verified through experimental tests on a Fanuc S-800 robot arm. These two models were used to estimate the overall modes of oscillation of an open container of liquid being carried by a robot arm. Using the estimated modes, inverse dynamic control techniques were used to determine a motion profile which would eliminate waves on the liquid`s surface. Experimental tests showed that residual surface waves in an open container of water at the end of motion were reduced by over 95% and that in-motion surface waves were reduced by over 75%.

  2. Assembly and Commissioning of a Liquid Argon Detector and Development of a Slow Control System for the COHERENT Experiment

    Science.gov (United States)

    Kaemingk, Michael; Cooper, Robert; Coherent Collaboration

    2016-09-01

    COHERENT is a collaboration whose goal is to measure coherent elastic neutrino-nucleus scattering (CEvNS). COHERENT plans to deploy a suite of detectors to measure the expected number-of-neutrons squared dependence of CEvNS at the Spallation Neutron Source at Oak Ridge National Laboratory. One of these detectors is a liquid argon detector which can measure these low energy nuclear recoil interactions. Ensuring optimal functionality requires the development of a slow control system to monitor and control various aspects, such as the temperature and pressure, of these detectors. Electronics manufactured by Beckhoff, Digilent, and Arduino among others are being used to create these slow control systems. This poster will generally discuss the assembly and commissioning of this CENNS-10 liquid argon detector at Indiana University and will feature work on the slow control systems.

  3. PLC Based Adaptive PID Control of Non Linear Liquid Tank System using Online Estimation of Linear Parameters by Difference Equations

    Directory of Open Access Journals (Sweden)

    Kesavan.E

    2013-04-01

    Full Text Available This paper suggests an idea to design an adaptive PID controller for Non-linear liquid tank System and is implemented in PLC. Online estimation of linear parameters (Time constant and Gain brings an exact model of the process to take perfect control action. Based on these estimated values, the controller parameters will be well tuned by internal model control. Internal model control is an unremarkably used technique and provides well tuned controller in order to have a good controlling process. PLC with its ability to have both continues control for PID Control and digital control for fault diagnosis which ascertains faults in the system and provides alerts about the status of the entire process.

  4. A dose-controlled system for air-liquid interface cell exposure and application to zinc oxide nanoparticles

    Directory of Open Access Journals (Sweden)

    Ferron George A

    2009-12-01

    Full Text Available Abstract Background Engineered nanoparticles are becoming increasingly ubiquitous and their toxicological effects on human health, as well as on the ecosystem, have become a concern. Since initial contact with nanoparticles occurs at the epithelium in the lungs (or skin, or eyes, in vitro cell studies with nanoparticles require dose-controlled systems for delivery of nanoparticles to epithelial cells cultured at the air-liquid interface. Results A novel air-liquid interface cell exposure system (ALICE for nanoparticles in liquids is presented and validated. The ALICE generates a dense cloud of droplets with a vibrating membrane nebulizer and utilizes combined cloud settling and single particle sedimentation for fast (~10 min; entire exposure, repeatable (2. The cell-specific deposition efficiency is currently limited to 0.072 (7.2% for two commercially available 6-er transwell plates, but a deposition efficiency of up to 0.57 (57% is possible for better cell coverage of the exposure chamber. Dose-response measurements with ZnO nanoparticles (0.3-8.5 μg/cm2 showed significant differences in mRNA expression of pro-inflammatory (IL-8 and oxidative stress (HO-1 markers when comparing submerged and air-liquid interface exposures. Both exposure methods showed no cellular response below 1 μg/cm2 ZnO, which indicates that ZnO nanoparticles are not toxic at occupationally allowed exposure levels. Conclusion The ALICE is a useful tool for dose-controlled nanoparticle (or solute exposure of cells at the air-liquid interface. Significant differences between cellular response after ZnO nanoparticle exposure under submerged and air-liquid interface conditions suggest that pharmaceutical and toxicological studies with inhaled (nano-particles should be performed under the more realistic air-liquid interface, rather than submerged cell conditions.

  5. Remotely controllable liquid marbles

    KAUST Repository

    Zhang, Lianbin

    2012-07-26

    Liquid droplets encapsulated by self-organized hydrophobic particles at the liquid/air interface - liquid marbles - are prepared by encapsulating water droplets with novel core/shell-structured responsive magnetic particles, consisting of a responsive block copolymer-grafted mesoporous silica shell and magnetite core (see figure; P2VP-b-PDMS: poly(2-vinylpyridine-b- dimethylsiloxane)). Desirable properties of the liquid marbles include that they rupture upon ultraviolet illumination and can be remotely manipulated by an external magnetic field. 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Application of Neural network PID Controller in Constant Temperature and Constant Liquid-level System

    Institute of Scientific and Technical Information of China (English)

    Chen,Guochu; Zhang,Lin; Hao,Ninmei; Liu,Xianguang; Wang,Junhong

    2003-01-01

    Guided by the principle of neural network, an intelligent PID controller based on neural network is devised and applied to control of constant temperature and constant liquidlevel system. The experiment results show that this controller has high accuracy and strong robustness and good characters.

  7. Test and Evaluation Station (TESt) - A Control System for the ALICE-HMPID Liquid Distribution Prototype

    CERN Document Server

    Maatta, E; CERN. Geneva; Swoboda, Detlef; Lecoeur, G

    1999-01-01

    The sub-detectors and systems in the ALICE experiment [1] are of various types. However, during physics runs, all devices necessary for the operation of the detector must be accessible and controllable through a common computer interface. Throughout all other periods each sub-detector requires maintenance, upgrading or test operation. To this end, an access independant of other sub-detectors must be guaranteed. These basic requirements impose a fair number of constraints on the architecture and components of the Detector Control System (DCS). The purpose of the TESt project consisted in the construction of a stand alone unit for a specific sub-system of an ALICE detector in order to gain first experience with commercial products for detector control. Although the control system includes only a small number of devices and is designed for a particular application, it covers nevertheless all layers of a complete system and can be extended or used in different applications. The control system prototype has been...

  8. Fluid Mechanics of Liquid-Liquid Systems.

    Science.gov (United States)

    Richards, John Reed

    The detailed hydrodynamics of selected liquid -liquid flow systems are investigated to provide a firm foundation for the rational design of separation processes. The implementation of this objective centers on the development of a robust code to simulate liquid-liquid flows. We have applied this code to the realistic simulation of aspects of the complex fluid mechanical behavior, and developed quantitative insight into the underlying processes involved. The Volume of Fluid (VOF) method is combined with the Continuous Surface Force (CSF) algorithm to provide a numerically stable code capable of solving high Reynolds numbers free surface flows. One of the developments during the testing was an efficient method for solving the Young-Laplace equation describing the shape of the meniscus in a vertical cylinder for a constrained liquid volume. The steady-state region near the nozzle for the laminar flow of a Newtonian liquid jet injected vertically into another immiscible Newtonian liquid is investigated for various Reynolds numbers by solving the axisymmetric transient equations of motion and continuity. The analysis takes into account pressure, viscous, inertial, gravitational, and surface tension forces, and comparison with previous experimental measurements shows good agreement. Comparisons of the present numerical method with the numerical results of previous boundary-layer methods help establish their range of validity. A new approximate equation for the shape of the interface of the steady jet, based on an overall momentum balance, is also developed. The full transient from liquid-liquid jet startup to breakup into drops is also simulated numerically. In comparison with experiment, the results of the present numerical method show a greater sensitivity of the jet length to the Reynolds number than the best predictions of previous linear stability analyses. The formation of drops is investigated at low to high Reynolds numbers before and after jet formation. The

  9. Liquid-circulating garment controls thermal balance

    Science.gov (United States)

    Kuznetz, L. H.

    1977-01-01

    Experimental data and mathematical model of human thermoregulatory system have been used to investigate use of liquid-circulatory garment (LCG) to control thermal balance. Model proved useful as accurate simulator of such variables as sweat rate, skin temperature, core temperature, and radiative, evaporative, and LCG heat loss.

  10. Integrated light-guide plates that can control the illumination angle for liquid crystal display backlight system

    Science.gov (United States)

    Feng, Di; Yang, Xingpeng; Jin, Guofan; Yan, Yingbai; Fan, Shoushan

    2006-01-01

    Liquid crystal displays (LCDs) with edge-lit backlight systems offer several advantages, such as low energy consuming, low weight, and high uniformity of intensity, over traditional cathode-ray tube displays, and make them ideal for many applications including monitors in notebook personal computers, screens for TV, and many portable information terminals, such as mobile phones, personal digital assistants, etc. To satisfy market requirements for mobile and personal display panels, it is more and more necessary to modify the backlight system and make it thinner, lighter, and brighter all at once. In this paper, we have proposed a new integrated LGP based on periodic and aperiodic microprism structures by using polymethyl methacrylate material, which can be designed to control the illumination angle, and to get high uniformity of intensity. So the backlight system will be simplified to use only light sources and one LGP without using other optical sheets, such as reflection sheet, diffusion sheet and prism sheets. By using optimizing program and ray tracing method, the designed LGPs can achieve a uniformity of intensity better than 86%, and get a peak illumination angle from +400 to -200, without requiring other optical sheets. We have designed a backlight system with only one LED light source and one LGP, and other LGP design examples with different sizes (1.8 inches and 14.1 inches) and different light source (LED or CCFL), are performed also.

  11. Alien liquid detector and control

    Energy Technology Data Exchange (ETDEWEB)

    Potter, B.M.

    1980-09-02

    An alien liquid detector employs a monitoring element and an energizing circuit for maintaining the temperature of the monitoring element substantially above ambient temperature. For this purpose an electronic circit controls a flow of heating current to the monitoring element. The presence of an alien liquid is detected by sensing a predetermined change in heating current flow to the monitoring element, e.g., to distinguish between water and oil. In preferred embodiments the monitoring element is a thermistor whose resistance is compared with a reference resistance and heating current through the thermistor is controlled in accordance with the difference. In one embodiment a bridge circuit senses the resistance difference; the difference may be sensed by an operational amplifier arrangement. Features of the invention include positioning the monitoring element at the surface of water, slightly immersed, so that the power required to maintain the thermistor temperature substantially above ambient temperature serves to detect presence of oil pollution at the surface.

  12. Design and Control of High Temperature PEM Fuel Cell Systems using Methanol Reformers with Air or Liquid Heat Integration

    DEFF Research Database (Denmark)

    Andreasen, Søren Juhl; Kær, Søren Knudsen; Sahlin, Simon Lennart

    2013-01-01

    The present work describes the ongoing development of high temperature PEM fuel cell systems fuelled by steam reformed methanol. Various fuel cell system solutions exist, they mainly differ depending on the desired fuel used. High temperature PEM (HTPEM) fuel cells offer the possibility of using...... methanol is converted to a hydrogen rich gas with CO2 trace amounts of CO, the increased operating temperatures allow the fuel cell to tolerate much higher CO concentrations than Nafion-based membranes. The increased tolerance to CO also enables the use of reformer systems with less hydrogen cleaning steps...... liquid fuels such as methanol, due to the increased robustness of operating at higher temperatures (160-180oC). Using liquid fuels such as methanol removes the high volume demands of compressed hydrogen storages, simplifies refueling, and enables the use of existing fuel distribution systems. The liquid...

  13. Design and Control of High Temperature PEM Fuel Cell Systems using Methanol Reformers with Air or Liquid Heat Integration

    DEFF Research Database (Denmark)

    Andreasen, Søren Juhl; Sahlin, Simon Lennart; Justesen, Kristian Kjær

    The present work describes the ongoing development of high temperature PEM fuel cell systems fuelled by steam reformed methanol. Various fuel cell system solutions exist, they mainly differ depending on the desired fuel used. High temperature PEM (HTPEM) fuel cells offer the possibility of using...... methanol is converted to a hydrogen rich gas with CO2 trace amounts of CO, the increased operating temperatures allow the fuel cell to tolerate much higher CO concentrations than Nafion-based membranes. The increased tolerance to CO also enables the use of reformer systems with less hydrogen cleaning steps...... liquid fuels such as methanol, due to the increased robustness of operating at higher temperatures (160-180oC). Using liquid fuels such as methanol removes the high volume demands of compressed hydrogen storages, simplifies refueling, and enables the use of existing fuel distribution systems. The liquid...

  14. Control system of liquid effluents generated in treatment with I-131; Sistema de control de efluentes liquidos generados en el tratamiento con I-131

    Energy Technology Data Exchange (ETDEWEB)

    Garcia M, T.; Ruiz C, M. A.; Angeles C, A.; Ramirez S, R., E-mail: teodoro.garcia@inin.gob.mx [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2015-09-15

    In recent years, nuclear medicine has developed greatly in our country and around the world. Techniques for both medical diagnosis and therapy have increased the use of radiopharmaceuticals, notably the I-131. In Mexico there are around 150 nuclear medicine establishments authorized by the Comision Nacional de Seguridad Nuclear y Salvaguardias. Most of these establishments do not have an appropriate facility for the treatment of radioactive liquid effluents, to ensure compliance with the concentration limits established in the regulations. The Instituto Nacional de Investigaciones Nucleares (ININ) developed and implemented successfully, a control system of radioactive effluents (named SACEL) from a nuclear medicine facility. This system ensures an effective compliance with regulations and also better management and control of these radioactive effluents. Calculations and design of SACEL were made with respect to I-131, because is one of the most commonly used in radiotherapy and medical diagnostics, besides its half-life is greater in relation to other radionuclides. SACEL is comprised of four storage tanks and decay and a fifth tank for measuring the concentration of I-131 and later discharge to the drain; these tanks are connected to an automated system that controls the effluents passage. The calculation to determine the volume of the tanks was carried out according to the demand that has the hospital, to the maximum activity being poured in effluents and time required to decay. In this paper the design and installation of SACEL system, in addition to functioning as a facility that enables the Hospital meet the required standards is presented. Dose calculations performed with MCNPX and the methodology used in the calibration of the detection system is also presented. (Author)

  15. Modeling of the flow continuum and optimal design of control-oriented injection systems in liquid composite molding processes

    Science.gov (United States)

    Gokce, Ali

    Several methodologies are presented in this dissertation that aim to ensure successful filling of the mold cavity consistently, during the mold filling stage of Liquid Composite Molding (LCM) processes such as Resin Transfer Molding (RTM), Vacuum Assisted Resin Transfer Molding (VARTM) and Seemann Composites Resin Infusion Molding (SCRIMP). Key parameters that affect the resin flow in the mold cavity can be divided into two main groups as continuum-related parameters and injection-related parameters. Flow continuum, which consists of all the spaces resin can reach in the mold cavity, has two major components: the porous medium, which is made up of the fiber reinforcements, and the flow channels that are introduced into the flow continuum unintentionally and offer an easy flow path to the resin. The properties that characterize the porous medium and the unintentional flow channels are continuum-related parameters. The injection-related parameters include resin injection locations (gates), resin injection conditions and air drainage locations (vents). Modeling the flow continuum is crucial in predicting the resin flow in the mold cavity. In this study, permeability, the key property of the porous medium, is predicted using the Method of Cells, a proven method to predict macroscopic properties of heterogeneous materials. Unintentional flow channels, which are also called racetracking channels, are modeled using a probabilistic approach. Injection-related parameters are the key tools to influence the resin flow in the mold cavity. In this study, Branch and Bound Search is modified for single gate optimization. Due to its pertinence to injection system design, the parameters that govern gate effectiveness in steering the resin advance are studied. A combinatorial search algorithm is proposed for vent optimization. Vent optimization and gate optimization algorithms are integrated for simultaneous gate and vent optimization. Overall, these methodologies reduce the cycle

  16. The Integrated HV, LV and Liquid Radiator Control System for the HMPID in the ALICE Experiment at LHC

    CERN Document Server

    Carrone, E; De Cataldo, G; Di Mauro, A; Franco, A; Martinengo, P; Nappi, E; Piuz, François; Schyns, E M

    2001-01-01

    The complexity and the underground location of the new generation experiments (ALICE, ATLAS, CMS and LHCb) at the CERN Large Hadron Collider (LHC) requires a reliable and user friendly control system to operate such large detectors remotely. Control system experts at CERN are deeply involved in developing the JCOP (Joint Controls Project) 'Framework', a software running in the PVSSII SCADA1 (Supervisory Control And Data Acquisition) system, that will provide a homogeneous and ready to use tool for the control system developers of the LHC experiments. The High Momentum Particle Identification Detector (HMPID), one of the ALICE2 sub-detectors, is being equipped with a Detector Control System (DCS) developed within the JCOP Framework. In this paper the basic features and the first results of the DCS prototype are presented.

  17. Gas absorption in an agitated gas-liquid-liquid system

    NARCIS (Netherlands)

    Cents, A.H.G.; Brilman, D.W.F.; Versteeg, G.F.

    2001-01-01

    Gas-liquid-liquid systems have gained interest in the past decade and are encountered in several important industrial applications. In these systems an immiscible liquid phase may affect the gas absorption rate significantly. This phenomenon, however, is not completely understood and underlying mech

  18. Post-scram Liquid Metal cooled Fast Breeder Reactor (LMFBR) neat transport system dynamics and steam generator control

    Science.gov (United States)

    Brukx, J. F. L. M.

    1982-06-01

    Loop type LMFBR heat transport system dynamics after reactor shutdown and during subsequent decay heat removal are considered with emphasis on steam generator dynamics including the development and evaluation of various post-scram steam generator control systems, and natural circulation of the sodium coolant, including the influence of superimposed free convection on forced convection heat transfer and pressure drop. The normal operating and decay heat removal functions of the overall heat transport system are described.

  19. 液体注肥器定量控制系统的设计%Design of Weighing Control System of Liquid Fertilizer Injector

    Institute of Scientific and Technical Information of China (English)

    邹伟; 王秀; 张睿; 郝强

    2013-01-01

      针对目前液体施肥机的不足,设计了可以定量控制施肥量的注肥控制系统。系统采用电机带动离心泵输送液态肥料,通过计算注肥器管道中流量传感器的脉冲信号,获取系统实际排出的液体体积,根据实际施肥量与设定值的差值控制电机运转,从而实现根据实际需要精确控制施肥量。实际运行结果表明,该系统运行可靠,系统对施肥控制量误差相对比较小,可以在一定程度上实现精准注肥,减少肥料浪费。%Because of deficiency of the liquid fertilizer applicator , the weighing control system of liquid fertilizer injector was designed .The liquid fertilizer is delivered by a centrifugal pump which adopts the motor drive .Through the calcula-tion of the flow sensor pulse signal in the pipe , the controller gains the actual discharged liquid volume .The difference between the actual value and the set value determines whether the motor running .The fertilizer control error of the system is relatively small , the crops can be fertilization accurately and the fertilizer waste can be reduced in a sense .

  20. Liquid Oxygen/Liquid Methane Integrated Propulsion System Test Bed

    Science.gov (United States)

    Flynn, Howard; Lusby, Brian; Villemarette, Mark

    2011-01-01

    In support of NASA?s Propulsion and Cryogenic Advanced Development (PCAD) project, a liquid oxygen (LO2)/liquid methane (LCH4) Integrated Propulsion System Test Bed (IPSTB) was designed and advanced to the Critical Design Review (CDR) stage at the Johnson Space Center. The IPSTB?s primary objectives are to study LO2/LCH4 propulsion system steady state and transient performance, operational characteristics and to validate fluid and thermal models of a LO2/LCH4 propulsion system for use in future flight design work. Two phase thermal and dynamic fluid flow models of the IPSTB were built to predict the system performance characteristics under a variety of operating modes and to aid in the overall system design work. While at ambient temperature and simulated altitude conditions at the White Sands Test Facility, the IPSTB and its approximately 600 channels of system instrumentation would be operated to perform a variety of integrated main engine and reaction control engine hot fire tests. The pressure, temperature, and flow rate data collected during this testing would then be used to validate the analytical models of the IPSTB?s thermal and dynamic fluid flow performance. An overview of the IPSTB design and analytical model development will be presented.

  1. Innovative technologies of liquid media treatment in the system of ecological and sanitary-hygienic control of waste landfills

    Directory of Open Access Journals (Sweden)

    Shevchenko Andrey

    2017-01-01

    Full Text Available The article focuses on the scientific and practical aspects of establishing a comprehensive system of environmental compliance for industrial and household waste landfills, including the system of industrial and environmental monitoring and control, modern innovations in the field of instrumental-analytical control of the state of environmental components, new methods of neutralization of complex industrial pollution. Priority is given to wastewater treatment from toxic compounds coming from the surface and drainage water seepage of landfill sites into surface and underground water sources.

  2. Variable Fertilizer Control System for Deep-fertilization Liquid Fertilizer Applicator%深施型液态肥变量施肥控制系统

    Institute of Scientific and Technical Information of China (English)

    郎春玲; 王金武; 王金峰; 何剑南; 郗晓焕

    2013-01-01

    A control system for variahle rate fertilization, which depends on deep-fertilization liquid fertilizer applicator, was introduced. The single chip microcomputer was used as core processor and electromagnetic proportion regulator valve was used as execution unit. Software was designed for selecting data and sending commands. The test results in the test-bed showed that the system can complete the control of variable rate fertilization and the error of the variable fertilizing was less than 0. 5 mL in each time, which meets the liquid fertilizer variables requirement.%以深施型液态施肥机为依托,采用单片机作为核心处理器,以电磁比例调节阀为执行部件,设计了深施型液态变量施肥控制系统.设计了与硬件配套的上位机软件,用于采集数据与发送命令.喷肥针施肥量控制误差台架试验结果表明,该系统可实现深施型液态变量施肥,施肥误差不超过0.5 mL/次,满足液态变量施肥作业要求.

  3. Development of a numerical simulator to control the liquid level of a subsea separator system; Dsenvolvimento de simulador numerico para controle de nivel de um sistema de separacao submarina

    Energy Technology Data Exchange (ETDEWEB)

    Shiguemoto, Denis; Rodrigues, Vinicius Mastelaro [DPR Engenharia, Campinas, SP (Brazil); Tsukada, Raphael; Mendes, Jose Ricardo Palaquim [Universidade Estadual de Campinas (UNICAMP), SP (Brazil); Serapiao, Adriane Beatriz de Souza [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Sao Paulo, SP (Brazil); Estevam, Valdir [Petroleo Brasileiro S.A. (PETROBRAS), Rio de Janeiro, RJ (Brazil)

    2012-07-01

    The challenges posed by recent discoveries of oil accumulations at bigger distances from the cost and ultra deep water depths (above 2500 meters) have stimulated the development of technologies and equipment to overcome these challenges. A major technological issue is the need for larger vessels capable of withstanding the weight of installed equipment and pipe production, which significantly increase the manufacturing cost which is already of the order of billions of dollars. The oil industry has focused efforts on developing solutions aimed to reduce weight installed on production platforms. In this context the Subsea Separation Systems was developed in order to carry out the primary processing under the water, thereby reducing the processing plant installed in the oil production platforms. It is a biphasic (liquid and gas) separator that sends the phases to the platform by means of independent pipes. This paper presents a numerical simulator developed to understand the behavior of the liquid level inside the Subsea Separations Systems for its operating conditions. A control system for liquid level was tested and evaluated considering the behavior of fluids within the Subsea Separation System and the pipes that carry them to the production unit. The numerical simulator developed allows a quick and practical understanding of the behavior of the liquid level inside the equipment and also the behavior of pressure and flow within the production pipe which produce benefits for the development design. (author)

  4. Control of thermal balance by a liquid circulating garment based on a mathematical representation of the human thermoregulatory system. Ph.D. Thesis - California Univ., Berkeley

    Science.gov (United States)

    Kuznetz, L. H.

    1976-01-01

    Test data and a mathematical model of the human thermoregulatory system were used to investigate control of thermal balance by means of a liquid circulating garment (LCG). The test data were derived from five series of experiments in which environmental and metabolic conditions were varied parametrically as a function of several independent variables, including LCG flowrate, LCG inlet temperature, net environmental heat exchange, surrounding gas ventilation rate, ambient pressure, metabolic rate, and subjective/obligatory cooling control. The resultant data were used to relate skin temperature to LCG water temperature and flowrate, to assess a thermal comfort band, to demonstrate the relationship between metabolic rate and LCG heat dissipation, and so forth. The usefulness of the mathematical model as a tool for data interpretation and for generation of trends and relationships among the various physiological parameters was also investigated and verified.

  5. Morphological control and polarization switching in polymer dispersed liquid crystal materials and devices

    Indian Academy of Sciences (India)

    K K Raina; Pankaj Kumar; Praveen Malik

    2006-11-01

    Liquid crystals dispersed in polymer systems constitute novel class of optical materials. The precise control of the liquid crystal droplet morphology in the polymer matrix is essentially required to meet the prerequisites of display device. Experiments have been carried out to investigate and identify the material properties and processing conditions required for the precise control of the droplet morphology of the dispersed liquid crystal systems. Polarization switching has been studied. Aligned liquid crystal dispersed systems showed higher polarization over unaligned ones.

  6. A new computer-controlled air-liquid interface cultivation system for the generation of differentiated cell cultures of the airway epithelium.

    Science.gov (United States)

    Aufderheide, Michaela; Förster, Christine; Beschay, Morris; Branscheid, Detlev; Emura, Makito

    2016-01-01

    The increased application of in vitro systems in pharmacology and toxicology requires cell culture systems that facilitate the cultivation process and ensure stable, reproducible and controllable cultivation conditions. Up to now, some devices have been developed for the cultivation of cells under submersed conditions. However, systems meeting the requirements of an air-liquid interface (ALI) cultivation for the special needs of bronchial epithelial cells for example are still lacking. In order to obtain in vivo like organization and differentiation of these cells they need to be cultivated under ALI conditions on microporous membranes in direct contact with the environmental atmosphere. For this purpose, a Long-Term-Cultivation system was developed (CULTEX(®) LTC-C system) for the computer-controlled cultivation of such cells. The transwell inserts are placed in an incubator module (24 inserts), which can be adjusted for the medium level (ultrasonic pulse-echosensor), time and volume-dependent medium exchange, and frequency for mixing the medium with a rotating disc for homogeneous distribution of medium and secretion components. Normal primary freshly isolated bronchial epithelial cells were cultivated for up to 38 days to show the efficiency of such a cultivation procedure for generating 3D cultures exhibiting in vivo-like pseudostratified organization of the cells as well as differentiation characteristics like mucus-producing and cilia-forming cells. Copyright © 2015 The Authors. Published by Elsevier GmbH.. All rights reserved.

  7. Fire Control System Design of Flammable Liquid Vertical Storage Tank Farm%可燃液体立式储罐罐区消防系统设计

    Institute of Scientific and Technical Information of China (English)

    时晓宁; 王全贵

    2016-01-01

    The paper introduces classification and structure of the fire-control cooling water system and foam fire-fighting system about the flammable liquid vertical storage tank farm, and combines some tank farm project engineering design example to expound the calculation process and the equipment selection of the fixed fire-control cooling water system as wel as the calculation process and equipment selection of fixed foam fire-fighting system.%介绍了甲、乙、丙类可燃液体立式储罐罐区消防冷却水系统和泡沫灭火系统的分类和组成,并结合某项目罐区工程设计实例阐述了固定式消防冷却水系统计算过程、设备选型以及固定式泡沫灭火系统计算过程和设备选型。

  8. Thermal energy storage with liquid-liquid systems

    Energy Technology Data Exchange (ETDEWEB)

    Santana, E.A.; Stiel, L.I. [Polytechnic Univ., Brooklyn, NY (United States)

    1989-03-01

    The use of liquid-liquid mixtures for heat and cool storage applications has been investigated. Suitable mixtures exhibit large changes in the heat of mixing above and below the critical solution temperature of the system. Analytical procedures have been utilized to determine potential energy storage capabilities of systems with upper or lower critical solution temperatures. It has been found that aqueous systems with lower critical solution temperatures in a suitable range can result in large increases in the effective heat capacity in the critical region. For cool storage with a system of this type, the cooling process results in a transformation from two liquid phases to a single phase. Heats of mixing have been measured with a flow calorimeter system for a number of potential mixtures, and the results are summarized.

  9. Application of the OPC Technology in Liquid Level Control System%OPC技术在液位控制中的应用

    Institute of Scientific and Technical Information of China (English)

    匡芬芳

    2011-01-01

    Aiming at the the difficulties in implementing communication among internal hardware and software of the computerized control systems, and the system is poor at the expandability, the multi-layer network control system based on OPC technology is proposed. The system is composed of a three-layer network that includes field operator stations, engineer station and expert station, and the internal information of the system can be transmitted among the three-layer network in real time with OPC technology. The structure and implementing method of program are discussed in detail. The design has been applied successfully in liquid level control object. The practice shows that the system is open, expandable and low cost in development; it is ease to implement information interaction and sharing for multiple software and hardware.%针对计算机控制系统内部各软硬件之间通信困难以及系统可扩展性差等问题,提出了一种基于OPC技术的多级网络控制系统.该系统由现场操作级、工程师站和专家站三级网络组成,借助OPC技术,系统内部信息可在三级网络间实时传递.详细探讨了系统结构及程序实现的方法,并将系统成功应用于液位对象的控制.实践表明,系统具有开放、可扩展和开发费用低廉等特点,便于实现多种软硬件之间的信息交互与共享.

  10. Design and research on liquid level control system of human imitation control algorithm based on the rule%基于规则的仿人控制算法液位控制系统设计与研究

    Institute of Scientific and Technical Information of China (English)

    赵静

    2016-01-01

    In the liquid level control process, the application traditional PID control to system devia-tion of the same, can not achieve the desired effect. Proportion integral control of humanoid with system error difference, but this algorithm still only residual error, system controllability is insufficient. In order to overcome this shortcoming, the humanoid control algorithm based on rules and controller parameter tuning method were proposed. The traditional PID control, proportional integral control and human simu-lated humanoid control based rules were compared, verify superiority of the intelligent control algorithm based on rules.%在液位控制过程中,应用传统的PID控制对系统偏差同等对待,不能达到理想的控制效果. 比例仿人积分控制对系统偏差区别对待,但这种控制算法仍存在余差,系统控制能力不足. 为了克服这一不足,提出基于规则的仿人控制算法以及控制器参数整定法,最后对传统的PID控制、比例仿人积分控制和基于规则的仿人控制进行了仿真比较,验证了基于规则的仿人控制算法的优越性.

  11. Automated system of control of radioactive liquid effluents of patients submitted to therapy in hospitals of nuclear medicine (SACEL); Sistema automatizado de control de efluentes liquidos radiactivos de pacientes sometidos a terapia en hospitales de medicina nuclear (SACEL)

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz C, M.A.; Rivero G, T.; Celis del Angel, L.; Sainz M, E.; Molina, G. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)]. e-mail: marc@nuclear.inin.mx

    2006-07-01

    Different hospitals of nuclear medicine require of the technical attendance for the design, construction and instrumentation of an effluents retention system coming from the room dedicated to the medical application of iodine 131, with the one object of giving execution to the normative requirements of radiological protection, settled down in the General Regulation of Radiological Safety (RGSR) emitted by the CNSNS in November, 1988 and in the corresponding official standards. An automatic system of flow measurement, the activity concentration of the effluents to the drainage, the discharges control and the automated report it will allow the execution of the national regulations, also the elimination of unhealthy activities as the taking of samples, analysis of those same and the corresponding paperwork, its will allow that the SACEL is capable of to carry out registrations that are to consult in an automated way. The changes in the demands of the National Commission of Nuclear Safety and Safeguards in relation to the liberation of radioactive material in hospitals by medical treatments, it has created the necessity to develop a system that quantifies and dose the liquid effluents of people under thyroid treatment with iodine-131 to the drainage. The Automated System of Control of radioactive liquids effluents generated in Hospitals of Nuclear Medicine (SACEL) developed in the National Institute of Nuclear Research, it fulfills this regulation, besides improving the work conditions for the medical and technical personnel of the hospital in that are installed, since this system has the advantage of to be totally automated and to require of a minimum of attendance. The SACEL is an electro-hydraulic system of effluents control, based in the alternate operation of two decay deposits of the activity of the material contaminated with iodine-131. The system allows to take a registration of those volumes and liberated dose, besides being able to be monitoring in remote

  12. A novel liquid system of catalytic hydrogenation

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    On the basis that endothermic aqueous-phase reforming of oxygenated hydrocarbons for H2 production and exothermic liquid phase hydrogenation of organic compounds are carried out under extremely close conditions of temperature and pressure over the same type of catalyst, a novel liquid system of catalytic hydrogenation has been proposed, in which hydrogen produced from aqueous-phase reforming of oxygenated hydrocarbons is in situ used for liquid phase hydrogenation of organic compounds. The usage of active hydrogen generated from aqueous-phase reforming of oxygenated hydrocarbons for liquid catalytic hydrogenation of organic compounds could lead to increasing the selectivity to H2 in the aqueous-phase reforming due to the prompt removal of hydrogen on the active centers of the catalyst. Meanwhile, this novel liquid system of catalytic hydrogenation might be a potential method to improve the selectivity to the desired product in liquid phase catalytic hydrogenation of organic compounds. On the other hand, for this novel liquid system of catalytic hydrogenation, some special facilities for H2 generation, storage and transportation in traditional liquid phase hydrogenation industry process are yet not needed. Thus, it would simplify the working process of liquid phase hydrogenation and increase the energy usage and hydrogen productivity.

  13. Liquid-Liquid Extraction in Systems Containing Butanol and Ionic Liquids – A Review

    Directory of Open Access Journals (Sweden)

    Kubiczek Artur

    2017-03-01

    Full Text Available Room-temperature ionic liquids (RTILs are a moderately new class of liquid substances that are characterized by a great variety of possible anion-cation combinations giving each of them different properties. For this reason, they have been termed as designer solvents and, as such, they are particularly promising for liquid-liquid extraction, which has been quite intensely studied over the last decade. This paper concentrates on the recent liquid-liquid extraction studies involving ionic liquids, yet focusing strictly on the separation of n-butanol from model aqueous solutions. Such research is undertaken mainly with the intention of facilitating biological butanol production, which is usually carried out through the ABE fermentation process. So far, various sorts of RTILs have been tested for this purpose while mostly ternary liquid-liquid systems have been investigated. The industrial design of liquid-liquid extraction requires prior knowledge of the state of thermodynamic equilibrium and its relation to the process parameters. Such knowledge can be obtained by performing a series of extraction experiments and employing a certain mathematical model to approximate the equilibrium. There are at least a few models available but this paper concentrates primarily on the NRTL equation, which has proven to be one of the most accurate tools for correlating experimental equilibrium data. Thus, all the presented studies have been selected based on the accepted modeling method. The reader is also shown how the NRTL equation can be used to model liquid-liquid systems containing more than three components as it has been the authors’ recent area of expertise.

  14. Quantum liquids in correlated systems

    Science.gov (United States)

    Kusminskiy, Silvia Viola

    quasiparticle dispersion. It is found that the electronic fluid can be described by a non-interacting-like dispersion but with renormalized parameters. The interacting theory is compared with recent cyclotron resonance experiments in this system. The results suggest that the electronic fluid can be described in terms of an effective Lorentz invariant theory with renormalized mass and velocity, the Dirac liquid.

  15. Cryogenic Control System

    Energy Technology Data Exchange (ETDEWEB)

    Goloborod' ko, S.; /Fermilab

    1989-02-27

    The control system (CS) for the cryogenic arrangement of the DO Liquid Argon Calorimeter consists of a Texas instruments 560/565 Programmable Logical Controller (PLC), two remote bases with Remote Base Controllers and a corresponding set of input/output (I/O) modules, and a PC AST Premium 286 (IBM AT Compatible). The PLC scans a set of inputs and provides a set of outputs based on a ladder logic program and PID control loops. The inputs are logic or analog (current, voltage) signals from equipment status switches or transducers. The outputs are logic or analog (current or voltage) signals for switching solenoids and positioning pneumatic actuators. Programming of the PLC is preformed by using the TISOFT2/560/565 package, which is installed in the PC. The PC communicates to the PLC through a serial RS232 port and provides operator interface to the cryogenic process using Xpresslink software.

  16. Phase-field simulation of liquid phase migration in the WC-Co system during liquid phase sintering

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Kaiming; Zhang, Lijun; Du, Yong [Central South Univ., Changsha (China). State Key Lab. of Powder Metallurgy; Schwarze, Christian; Steinbach, Ingo [Bochum Univ. (Germany). Interdisciplinary Centre for Advanced Materials Simulation

    2016-04-15

    Liquid phase sintering is a process for forming high performance, multiple-phase components from powders. The process includes very complex interactions between various mass transportation phenomena, among which the liquid phase migration represents an important one in the aspect of forming a gradient structure in cemented carbide. In the present work, phase-field simulation of the liquid phase migration phenomenon during liquid phase sintering is performed in the WC-Co based cemented carbide. The simulation results are analyzed and compared with the experimentally determined key factors of microstructural evolution, such as contiguity and liquid phase migration rate. The diffusion-controlled solution-precipitation mechanism of the liquid phase migration process in the cemented carbide system is confirmed from the current simulation result, which provides deeper understanding of the microstructural evolution during the liquid phase migration process. These simulations can offer guidance in preventing the liquid phase migration process during liquid phase sintering of cellular cemented carbide.

  17. Solution processing of polymer semiconductor: Insulator blends-Tailored optical properties through liquid-liquid phase separation control

    KAUST Repository

    Hellmann, Christoph

    2014-12-17

    © 2014 Wiley Periodicals, Inc. It has been demonstrated that the 0-0 absorption transition of poly(3-hexylthiophene) (P3HT) in blends with poly(ethylene oxide) (PEO) could be rationally tuned through the control of the liquid-liquid phase separation process during solution deposition. Pronounced J-like aggregation behavior, characteristic for systems of a low exciton band width, was found for blends where the most pronounced liquid-liquid phase separation occurred in solution, leading to domains of P3HT and PEO of high phase purity. Since liquid-liquid phase separation could be readily manipulated either by the solution temperature, solute concentration, or deposition temperature, to name a few parameters, our findings promise the design from the out-set of semiconductor:insulator architectures of pre-defined properties by manipulation of the interaction parameter between the solutes as well as the respective solute:solvent system using classical polymer science principles.

  18. Liquidity Risk – Measurement and Control

    OpenAIRE

    Blahová, Naďa

    2012-01-01

    The article deals with the liquidity risk in the banks in the context of the financial crisis. At first, the balance sheet and market liquidity are defined and the main principles of the methods for measuring liquidity risk, which banks use, are identified. Then follow review of main challenges of managing the liquidity of banks. Finally, it discusses qualitative regulatory requirements and eligibility of newly formulated standards with regard to minimum liquidity in general and in relation t...

  19. 舞钢VOD炉热井液位PID控制系统的开发及应用%Development and Application of Hot Well TanK Liquid Level PID Control System for Wugang′s VOD

    Institute of Scientific and Technical Information of China (English)

    邢党辉; 贾淑荣

    2014-01-01

    针对舞钢公司 VOD 炉热井系统对恒液位的需要,介绍了一种水箱恒液位 PID 控制系统的开发与设计。该系统通过西门子 S7-400系列 PLC 指令实现对液位的 PID 闭环控制,液位传感器将液位值作为反馈信号传给 PLC,对变频器进行调节控制,实现电机转速调节,从而达到恒液位控制目的。运行结果表明改造取得了节能降耗的效果。%For the demand of hot well tank in Wugang′s VOD system on constant liquid level,the paper intro-duces the development and design of PID for constant liquid level control of hot well tank. The system uses the com-mand from Siemens S7 - 400 series PLC to achieve PID closed loop control over liquid level. The PLC receives the sig-nal from liquid level sensor as feedback. The signal from liquid level sensor feedback to PLC controls the frequency con-verter. The converter regulates the rotational speed of motor so as to achieve constant liquid level control. The opera-tion result proves that the revamp reduces power consumption and maintenance cost.

  20. Control of liquid column height in electromagnetic casting with fuzzy neural network model

    Institute of Scientific and Technical Information of China (English)

    李朝霞; 郑贤淑

    2002-01-01

    The control of suitable and stable height of liquid column is the crucial point to operate the electromagnetic casting(EMC) process and to obtain ingots with desirable shape and dimensional accuracy. But due to the complicated interact parameters and special circumstances, the measure and control of liquid column are quite difficult. A fuzzy neural network was used to help control the liquid column by predicting its height on line. The results show that the stabilization of the height of liquid column and surface quality of the ingot are remarkably improved by using the neural network based control system.

  1. Modeling the Capillary Pressure for the Migration of the Liquid Phase in Granular Solid-Liquid-Vapor Systems: Application to the Control of the Composition Profile in W-Cu FGM Materials

    Science.gov (United States)

    Missiaen, Jean-Michel; Raharijaona, Jean-Joël; Delannay, Francis

    2016-11-01

    A model is developed to compute the capillary pressure for the migration of the liquid phase out or into a uniform solid-liquid-vapor system. The capillary pressure is defined as the reduction of the overall interface energy per volume increment of the transferred fluid phase. The model takes into account the particle size of the solid particle aggregate, the packing configuration (coordination number, porosity), the volume fractions of the different phases, and the values of the interface energies in the system. The model is used for analyzing the stability of the composition profile during processing of W-Cu functionally graded materials combining a composition gradient with a particle size gradient. The migration pressure is computed with the model in two stages: (1) just after the melting of copper, i.e., when sintering and shape accommodation of the W particle aggregate can still be neglected and (2) at high temperature, when the system is close to full density with equilibrium particle shape. The model predicts well the different stages of liquid-phase migration observed experimentally.

  2. Supersonic Gas-Liquid Cleaning System

    Science.gov (United States)

    Kinney, Frank

    1996-01-01

    The Supersonic Gas-Liquid Cleaning System Research Project consisted mainly of a feasibility study, including theoretical and engineering analysis, of a proof-of-concept prototype of this particular cleaning system developed by NASA-KSC. The cleaning system utilizes gas-liquid supersonic nozzles to generate high impingement velocities at the surface of the device to be cleaned. The cleaning fluid being accelerated to these high velocities may consist of any solvent or liquid, including water. Compressed air or any inert gas is used to provide the conveying medium for the liquid, as well as substantially reduce the total amount of liquid needed to perform adequate surface cleaning and cleanliness verification. This type of aqueous cleaning system is considered to be an excellent way of conducting cleaning and cleanliness verification operations as replacements for the use of CFC 113 which must be discontinued by 1995. To utilize this particular cleaning system in various cleaning applications for both the Space Program and the commercial market, it is essential that the cleaning system, especially the supersonic nozzle, be characterized for such applications. This characterization consisted of performing theoretical and engineering analysis, identifying desirable modifications/extensions to the basic concept, evaluating effects of variations in operating parameters, and optimizing hardware design for specific applications.

  3. Water Ionic Liquid-Crown Ether System Controlling Morphologies and Sizes of Soluble Polypyrrole Nanostructures and Their Self-Assembly Behaviors in the System

    Science.gov (United States)

    Yavari, Issa; Kowsari, Elaheh

    The present study reports a novel chemical route to synthesize different sizes of conducting polypyrrol (ppy) nanoparticles by hydrogen-bonding directionality in the presence of a crown ether, ionic liquid ([octmim]Br, octhyl-methyl imidazulim bromide) and ammonium persulfate in HCl solution. The morphology of the nanoparticle of PPy was confirmed by SEM images. The effects of reaction conditions on the morphology of the resultant ppy nanostructures were studied. The conductivity of the product varied with the mass ratio of aniline monomer to crown ether and IL. The chemical and electronic structures of the ppy nanoparticle were also studied by FT-IR and UV-Vis spectrometry, respectively.

  4. Tailoring liquid crystalline lipid nanomaterials for controlled release of macromolecules.

    Science.gov (United States)

    Bisset, Nicole B; Boyd, Ben J; Dong, Yao-Da

    2015-11-10

    Lipid-based liquid crystalline materials are being developed as drug delivery systems. However, the use of these materials for delivery of large macromolecules is currently hindered by the small size of the water channels in these structures limiting control over diffusion behaviour. The addition of the hydration-modulating agent, sucrose stearate, to phytantriol cubic phase under excess water conditions incrementally increased the size of these water channels. Inclusion of oleic acid enabled further control of swelling and de-swelling of the matrix via a pH triggerable system where at low pH the hexagonal phase is present and at higher pH the cubic phase is present. Fine control over the release of various sized model macromolecules is demonstrated, indicating future application to controlled loading and release of large macromolecules such as antibodies. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Polynomial Digital Control of a Series Equal Liquid Tanks

    Directory of Open Access Journals (Sweden)

    Bobála Vladimír

    2016-01-01

    Full Text Available Time-delays are mainly caused by the time required to transport mass, energy or information, but they can also be caused by processing time or accumulation. Typical examples of such processes are e.g. pumps, liquid storing tanks, distillation columns or some types of chemical reactors. In many cases time-delay is caused by the effect produced by the accumulation of a large number of low-order systems. Several industrial processes have the time-delay effect produced by the accumulation of a great number of low-order systems with the identical dynamic. The dynamic behavior of series these low-order systems is expressed by high-order system. One of possibilities of control of such processes is their approximation by low-order model with time-delay. The paper is focused on the design of the digital polynomial control of a set of equal liquid cylinder atmospheric tanks. The designed control algorithms are realized using the digital Smith Predictor (SP based on polynomial approach – by minimization of the Linear Quadratic (LQ criterion. The LQ criterion was combined with pole assignment.

  6. Bireactor Electronuclear Systems with Liquid Cadmium Valve

    CERN Document Server

    Bznuni, S A; Zhamkochyan, V M; ASosnin, A N; Polanski, A; Khudaverdyan, A H

    2002-01-01

    Three main types of bireactor electronuclear systems are discussed. From the point of view of assuring high level of functional characteristics and safety bireactor electronuclear systems with booster using enriched uranium (20 %) and with a liquid cadmium valve appears to be the most effective. It is shown by means of Monte-Carlo modeling that such operation conditions can be achieved which lead to the destruction of the intermediate cadmium layer making the systems supercritical (k_{eff}>1). One can avoid the problem by using a special design of the liquid cadmium valve. In comparison with other nuclear systems (critical reactors, one-reactor electronuclear systems) cascade electronuclear systems have essential advantages allowing the decrease of the proton beam current by one order of magnitude and providing at same time the necessary level of power generation and neutron flux. Availability of both the thermal and fast cones allows one to transmute not only transuranics but also the fission products - cesi...

  7. 锅炉储水罐液位控制系统的创新设计%Innovative Design of Liquid Level Control System of Boiler Water Storage Tank

    Institute of Scientific and Technical Information of China (English)

    胡江平

    2014-01-01

    In view of the imperfect of the existing boiler whose control device of liquid level of water storage tank can't accu-rately control water level, this paper designed a kind of safe ,reliable and accurate ultrasonic liquid level control system. Through the ultrasonic non-contact measurement, the chemical and physical properties of liquid of the system turned out to be adaptively strong. Simple structure, easy installation, high measurement precision, wide applicability integrate the system.%针对现有锅炉储水罐液位控制装置,不能精确控制水位的缺陷,设计了一种安全可靠、精确度高的超声波液位控制系统。该系统通过超声波非接触测量,液体的物理、化学性质的适应性极强。该系统结构简单、安装方便、测量精度高、适用性广。

  8. Liquid metals fire control engineering handbook

    Energy Technology Data Exchange (ETDEWEB)

    Ballif, J.L. (comp.)

    1979-02-01

    This handbook reviews the basic requirements of the use of liquid metals with emphasis on sodium which has the greatest current usage. It delineates the concepts necessary to design facilities both radioactive and nonradioactive for use with liquid metals. It further reviews the state-of-the-art in fire extinguishers and leak detection equipment and comments on their application and sensitivity. It also provides details on some engineering features of value to the designer of liquid metal facilities.

  9. Controlling Liquid Release by Compressing Electrospun Nanowebs

    Directory of Open Access Journals (Sweden)

    K.G. Kornev

    2009-09-01

    Full Text Available Electrospun nanowebs with pores ranging from nanometers to micrometers, constitute new materials with enhanced absorbency and ability to retain liquids in pores for a long period of time. These materials can be used as nanofluidic probes collecting minute amount of liquids. However, extraction of liquids from nanofibrous materials presents a problem: menisci in the interfiber pores create very high suction pressure which holds the liquid inside the material. This problem can be resolved if the probe is completely filled with the liquid: menisci at the probe edges become flat to establish a pressure equilibrium with the atmosphere. Therefore, one can take advantage of the nanoweb softness and extract liquid by mechanically deforming the nanowebs. We show that the liquid-saturated nanowebs follow the Voigt-type rheology upon loading. We theoretically explain this behavior and derive the relations between the Voigt phenomenological parameters, nanoweb permeability and compression modulus. We show that the limiting deformations follow the Hooke’s law which assumes linear relation between the extracted volume of liquid and the applied load. Because of this predictable behavior, the nanoweb probes can be engineered to release minute liquid doses upon compression. The developed experimental methodology can be used for characterization of nanostructured materials which otherwise impossible to analyze by using the existing instruments.

  10. Modeling of Ultrasonically Generated Liquid-Liquid Dispersions During Controlled Directional Solidification

    Science.gov (United States)

    Grugel, R. N.; Fedoseyev, A. I.

    2000-01-01

    There are innumerable two-component systems in which two very different liquid phases co-exist in equilibrium over a range of temperature and composition, e.g., oil and water, salt fluxes and solders, aluminum and lead. Often it is of practical concern to fabricate a solid component consisting of a uniform dispersion of one phase in the other. Unfortunately, uniform microstructural development during solidification of two immiscible liquids is hampered by inherent, often large, density differences between the phases that lead to severe segregation. Uniformity is also compromised by preferential wetting and coalescence phenomena. It is, however, well known that ultrasonic energy can initiate and maintain a fine liquid-liquid dispersion. The work presented here extends that observation by application of ultrasonic energy to promote uniform phase incorporation during controlled directional solidification. To this end experiments with the transparent organic, immiscible, succinonitrile-glycerol system were conducted and the numerous processing parameters associated with this technique were evaluated in view of optimizing dispersion uniformity. In view of the initial experimental results a model that predicts the dispersed liquid droplet size as a function of material properties, sample geometry, and applied energy has been developed. In the mathematical model we consider the ultrasonic field in an experimental ampoule of length L and diameter D induced by a probe having a vibration frequency of f=2OKhz (circular frequency omega = 2 pi f). The amplitude is adjustable from A=65 to 13Omicrons. The probe tip diameter is d, the liquid has a density of p, in which the speed of sound and surface tension are, respectively, c and sigma. The mathematical model and numerical investigation for the experiments [1] is done using the following assumptions: (i) The droplet size is small in comparison to the sound wave length; (ii) The forces between droplets are neglected (relative

  11. Microprocessor Control For Liquid-Cooled Garment

    Science.gov (United States)

    Weaver, Charles S.

    1990-01-01

    Automatic control system maintains temperature of water-cooled garment within comfort zone while wearer's level of physical activity varies. Uncomfortable overshoots and undershoots of temperature eliminated. Designed for use in space suit, adaptable to other protective garments and to enclosed environments operating according to similar principles.

  12. Mass transfer and chemical reaction in gas-liquid-liquid systems

    NARCIS (Netherlands)

    Brilman, Derk Willem Frederik

    1998-01-01

    Gas-liquid-liquid reaction systems may be encountered in several important fields of application as e.g. hydroformylation, alkylation, carboxylation, polymerisation, hydrometallurgy, biochemical processes and fine chemicals manufacturing. However, the reaction engineering aspects of these systems ha

  13. Theoretical and experimental investigation into the explosive boiling potential of thermally stratified liquid-liquid systems

    NARCIS (Netherlands)

    Fabiano, B.; Kersten, R.J.A.; Opschoor, G.; Pastorino, R.

    2002-01-01

    The occurrence of a rapid phase transition, or so-called explosive boiling, when a cold volatile liquid comes into contact with a hot liquid or hot surface is a potential hazard in industry. This study was focused on the explosive boiling potential of thermally stratified liquid-liquid systems that

  14. Liquid chromatography detection unit, system, and method

    Energy Technology Data Exchange (ETDEWEB)

    Derenzo, Stephen E.; Moses, William W.

    2015-10-27

    An embodiment of a liquid chromatography detection unit includes a fluid channel and a radiation detector. The radiation detector is operable to image a distribution of a radiolabeled compound as the distribution travels along the fluid channel. An embodiment of a liquid chromatography system includes an injector, a separation column, and a radiation detector. The injector is operable to inject a sample that includes a radiolabeled compound into a solvent stream. The position sensitive radiation detector is operable to image a distribution of the radiolabeled compound as the distribution travels along a fluid channel. An embodiment of a method of liquid chromatography includes injecting a sample that comprises radiolabeled compounds into a solvent. The radiolabeled compounds are then separated. A position sensitive radiation detector is employed to image distributions of the radiolabeled compounds as the radiolabeled compounds travel along a fluid channel.

  15. Liquid chromatography detection unit, system, and method

    Science.gov (United States)

    Derenzo, Stephen E.; Moses, William W.

    2015-10-27

    An embodiment of a liquid chromatography detection unit includes a fluid channel and a radiation detector. The radiation detector is operable to image a distribution of a radiolabeled compound as the distribution travels along the fluid channel. An embodiment of a liquid chromatography system includes an injector, a separation column, and a radiation detector. The injector is operable to inject a sample that includes a radiolabeled compound into a solvent stream. The position sensitive radiation detector is operable to image a distribution of the radiolabeled compound as the distribution travels along a fluid channel. An embodiment of a method of liquid chromatography includes injecting a sample that comprises radiolabeled compounds into a solvent. The radiolabeled compounds are then separated. A position sensitive radiation detector is employed to image distributions of the radiolabeled compounds as the radiolabeled compounds travel along a fluid channel.

  16. Liquid Oxygen Thermodynamic Vent System Testing with Helium Pressurization

    Science.gov (United States)

    VanDresar, Neil T.

    2014-01-01

    This report presents the results of several thermodynamic vent system (TVS) tests with liquid oxygen plus a test with liquid nitrogen. In all tests, the liquid was heated above its normal boiling point to 111 K for oxygen and 100 K for nitrogen. The elevated temperature was representative of tank conditions for a candidate lunar lander ascent stage. An initial test series was conducted with saturated oxygen liquid and vapor at 0.6 MPa. The initial series was followed by tests where the test tank was pressurized with gaseous helium to 1.4 to 1.6 MPa. For these tests, the helium mole fraction in the ullage was quite high, about 0.57 to 0.62. TVS behavior is different when helium is present than when helium is absent. The tank pressure becomes the sum of the vapor pressure and the partial pressure of helium. Therefore, tank pressure depends not only on temperature, as is the case for a pure liquid-vapor system, but also on helium density (i.e., the mass of helium divided by the ullage volume). Thus, properly controlling TVS operation is more challenging with helium pressurization than without helium pressurization. When helium was present, the liquid temperature would rise with each successive TVS cycle if tank pressure was kept within a constant control band. Alternatively, if the liquid temperature was maintained within a constant TVS control band, the tank pressure would drop with each TVS cycle. The final test series, which was conducted with liquid nitrogen pressurized with helium, demonstrated simultaneous pressure and temperature control during TVS operation. The simultaneous control was achieved by systematic injection of additional helium during each TVS cycle. Adding helium maintained the helium partial pressure as the liquid volume decreased because of TVS operation. The TVS demonstrations with liquid oxygen pressurized with helium were conducted with three different fluid-mixer configurations-a submerged axial jet mixer, a pair of spray hoops in the tank

  17. 液氯包装泵输送过程自动控制系统%Automatic Control System in the Liquid Cl2 Transport Process by the Packing Pump

    Institute of Scientific and Technical Information of China (English)

    赵石平

    2001-01-01

    Adopt the programmable controller in the liquid Cl2 transport process by the packing Pump. Assure the security of production. Utilize the functions of select control. Have fulfilled, conveniently and securely, the soft transfer in reserve system.%采用可编程序调节器对液氯包装泵输送过程进行自动控制,保证安全生产。利用可编程序调节器的选择控制功能,方便可靠地实现备用系统的软切换。

  18. Data liquidity in health information systems.

    Science.gov (United States)

    Courtney, Paul K

    2011-01-01

    In 2001, the Institute of Medicine report Crossing the Quality Chasm and the National Committee on Vital and Health Statistics report Information for Health were released, and they provided the context for the development of information systems used to support health-supporting processes. Both had as their goals, implicit or explicit, to ensure the right data are provided to the right person at the right time, which is one definition of "data liquidity." This concept has had some traction in recent years as a shorthand way to express a system property for health information technology, but there is not a well-defined characterization of what properties of a system or of its components give it better or worse data liquidity. This article looks at some recent work that help to identify those properties and perhaps can help to ground the concept with metrics that are assessable.

  19. Ultrastable Liquid-Liquid Interface as Viable Route for Controlled Deposition of Biodegradable Polymer Nanocapsules.

    Science.gov (United States)

    Vecchione, Raffaele; Iaccarino, Giulia; Bianchini, Paolo; Marotta, Roberto; D'autilia, Francesca; Quagliariello, Vincenzo; Diaspro, Alberto; Netti, Paolo A

    2016-06-01

    Liquid-liquid interfaces are highly dynamic and characterized by an elevated interfacial tension as compared to solid-liquid interfaces. Therefore, they are gaining an increasing interest as viable templates for ordered assembly of molecules and nanoparticles. However, liquid-liquid interfaces are more difficult to handle compared to solid-liquid interfaces; their intrinsic instability may affect the assembly process, especially in the case of multiple deposition. Indeed, some attempts have been made in the deposition of polymer multilayers at liquid-liquid interfaces, but with limited control over size and stability. This study reports on the preparation of an ultrastable liquid-liquid interface based on an O/W secondary miniemulsion and its possible use as a template for the self-assembly of polymeric multilayer nanocapsules. Such polymer nanocapsules are made of entirely biodegradable materials, with highly controlled size-well under 200 nm-and multi-compartment and multifunctional features enriching their field of application in drug delivery, as well as in other bionanotechnology fields.

  20. A Small Transfer and Distribution System for Liquid Nitrogen

    Directory of Open Access Journals (Sweden)

    Č. Šimáně

    2001-01-01

    Full Text Available A system for remotely controlled filling of small Dewars with liquid nitrogen from a central storage Dewar vessel is described, consisting of a plunger type pump with an electromechanical driver and electromechanical ball type valves for distribution of liquid nitrogen. The preset nitrogen level in the small Dewars is kept constant by automatic refilling. The delivery is adjustable in steps by frequency change from 2.5 to 25 cm3/s, and delivery height up to 2 meters is assured.

  1. Reactor models for a series of continuous stirred tank reactors with a gas-liquid-solid leaching system: Part I. Surface reaction control

    Science.gov (United States)

    Papangelakis, V. G.; Demopoulos, G. P.

    1992-12-01

    In this three-part series of articles, comprehensive three-phase steady-state hydrometallurgical reactor models of the continuous stirred tank reactor (CSTR) type are developed and applied to a commercial (pressure oxidation) process. The key features of the developed models are the coupling of both mass and heat balance equations, the description of the nonisothermal performance (autothermal) of a multistage continuous reactor, and the treatment of multimineral feed materials. The model considers only the oxidation reactions, because they mainly affect the thermal balance of the reactor. The stoichiometries and intrinsic kinetics of the heterogeneous leaching reactions, which are established via independent experiments, are the foundation of the developed model. A three-phase (g-l-s) reaction process might be controlled by either surface reaction control, i.e., the rate(s) of the heterogeneous leaching reaction(s), or by gas transfer control, i.e., the rate of transfer of the gaseous reactant into the liquid phase. In the present article (Part I), the case of surface reaction control is treated. The article addresses, in particular, the following topics: (1) it outlines the basic mass and heat balance equations which describe the performance of a multistage leaching reactor; (2) it presents a continuous function to describe the particle size distribution of the feed; and (3) it develops, on the basis of probability theory, number- and mass-particle size density functions which give the size distribution of particle populations reacting according to the surface reaction control-shrinking core model.

  2. Solar Thermal Upper Stage Liquid Hydrogen Pressure Control Testing

    Science.gov (United States)

    Moore, J. D.; Otto, J. M.; Cody, J. C.; Hastings, L. J.; Bryant, C. B.; Gautney, T. T.

    2015-01-01

    High-energy cryogenic propellant is an essential element in future space exploration programs. Therefore, NASA and its industrial partners are committed to an advanced development/technology program that will broaden the experience base for the entire cryogenic fluid management community. Furthermore, the high cost of microgravity experiments has motivated NASA to establish government/aerospace industry teams to aggressively explore combinations of ground testing and analytical modeling to the greatest extent possible, thereby benefitting both industry and government entities. One such team consisting of ManTech SRS, Inc., Edwards Air Force Base, and Marshall Space Flight Center (MSFC) was formed to pursue a technology project designed to demonstrate technology readiness for an SRS liquid hydrogen (LH2) in-space propellant management concept. The subject testing was cooperatively performed June 21-30, 2000, through a partially reimbursable Space Act Agreement between SRS, MSFC, and the Air Force Research Laboratory. The joint statement of work used to guide the technical activity is presented in appendix A. The key elements of the SRS concept consisted of an LH2 storage and supply system that used all of the vented H2 for solar engine thrusting, accommodated pressure control without a thermodynamic vent system (TVS), and minimized or eliminated the need for a capillary liquid acquisition device (LAD). The strategy was to balance the LH2 storage tank pressure control requirements with the engine thrusting requirements to selectively provide either liquid or vapor H2 at a controlled rate to a solar thermal engine in the low-gravity environment of space operations. The overall test objective was to verify that the proposed concept could enable simultaneous control of LH2 tank pressure and feed system flow to the thruster without necessitating a TVS and a capillary LAD. The primary program objectives were designed to demonstrate technology readiness of the SRS concept

  3. Control system design method

    Science.gov (United States)

    Wilson, David G [Tijeras, NM; Robinett, III, Rush D.

    2012-02-21

    A control system design method and concomitant control system comprising representing a physical apparatus to be controlled as a Hamiltonian system, determining elements of the Hamiltonian system representation which are power generators, power dissipators, and power storage devices, analyzing stability and performance of the Hamiltonian system based on the results of the determining step and determining necessary and sufficient conditions for stability of the Hamiltonian system, creating a stable control system based on the results of the analyzing step, and employing the resulting control system to control the physical apparatus.

  4. Algorithm design of liquid lens inspection system

    Science.gov (United States)

    Hsieh, Lu-Lin; Wang, Chun-Chieh

    2008-08-01

    In mobile lens domain, the glass lens is often to be applied in high-resolution requirement situation; but the glass zoom lens needs to be collocated with movable machinery and voice-coil motor, which usually arises some space limits in minimum design. In high level molding component technology development, the appearance of liquid lens has become the focus of mobile phone and digital camera companies. The liquid lens sets with solid optical lens and driving circuit has replaced the original components. As a result, the volume requirement is decreased to merely 50% of the original design. Besides, with the high focus adjusting speed, low energy requirement, high durability, and low-cost manufacturing process, the liquid lens shows advantages in the competitive market. In the past, authors only need to inspect the scrape defect made by external force for the glass lens. As to the liquid lens, authors need to inspect the state of four different structural layers due to the different design and structure. In this paper, authors apply machine vision and digital image processing technology to administer inspections in the particular layer according to the needs of users. According to our experiment results, the algorithm proposed can automatically delete non-focus background, extract the region of interest, find out and analyze the defects efficiently in the particular layer. In the future, authors will combine the algorithm of the system with automatic-focus technology to implement the inside inspection based on the product inspective demands.

  5. Liquid metal ion source analysis system

    Energy Technology Data Exchange (ETDEWEB)

    Marriott, P.

    1986-06-14

    An analysis system for angular and mass resolved energy distribution measurements of liquid metal ion source beams has been constructed. The energy analyser has been calibrated, and preliminary on-axis energy distribution measurements of a gallium source operating between 0.26 and 30.0 ..mu..A have been made. These results closely agree with measurements reported by other workers, confirming the unusual FWHM behaviour of gallium sources below approx. 2 ..mu..A.

  6. Correlation of liquid-liquid equilibria of non-ideal binary systems by NRTL model

    Directory of Open Access Journals (Sweden)

    Grozdanić Nikola D.

    2013-01-01

    Full Text Available Non Random Two Liquid model (NRTL with three different forms of temperature dependant parameters was used to correlate the liquid - liquid equilibrium data for systems of alcohols with alkanes, and alcohols with two ionic liquids: 1-butyl-2,3-dimethylimidazolium tetrafluoroborate ([bmmim][BF4] and 1-butyl-3-ethylimidazolium tetrafluoroborate ([beim][BF4]. Different temperature dependences of NRTL parameters were tested on thirteen literature experimental liquid - liquid equilibrium data for binary systems. [Projekat Ministarstva nauke Republike Srbije, br. 172063

  7. Distributed computer control systems

    Energy Technology Data Exchange (ETDEWEB)

    Suski, G.J.

    1986-01-01

    This book focuses on recent advances in the theory, applications and techniques for distributed computer control systems. Contents (partial): Real-time distributed computer control in a flexible manufacturing system. Semantics and implementation problems of channels in a DCCS specification. Broadcast protocols in distributed computer control systems. Design considerations of distributed control architecture for a thermal power plant. The conic toolset for building distributed systems. Network management issues in distributed control systems. Interprocessor communication system architecture in a distributed control system environment. Uni-level homogenous distributed computer control system and optimal system design. A-nets for DCCS design. A methodology for the specification and design of fault tolerant real time systems. An integrated computer control system - architecture design, engineering methodology and practical experience.

  8. Liquid-crystal intraocular adaptive lens with wireless control

    NARCIS (Netherlands)

    Simonov, A.N.; Vdovine, G.V.; Loktev, M.

    2007-01-01

    We present a prototype of an adaptive intraocular lens based on a modal liquid-crystal spatial phase modulator with wireless control. The modal corrector consists of a nematic liquid-crystal layer sandwiched between two glass substrates with transparent low- and high-ohmic electrodes, respectively.

  9. Liquid-crystal intraocular adaptive lens with wireless control

    NARCIS (Netherlands)

    Simonov, A.N.; Vdovine, G.V.; Loktev, M.

    2007-01-01

    We present a prototype of an adaptive intraocular lens based on a modal liquid-crystal spatial phase modulator with wireless control. The modal corrector consists of a nematic liquid-crystal layer sandwiched between two glass substrates with transparent low- and high-ohmic electrodes, respectively.

  10. Charge-Controlled Colloids on Liquid-Liquid Interfaces

    Science.gov (United States)

    Kunz, Daniel A.; Reck, Bernd; Manoharan, Vinothan N.

    2014-03-01

    The tendency of colloidal particles to stabilize interfaces has been exploited for many years to generate Pickering emulsions with a variety of industrial applications. However, the exact stabilization mechanism and its dependence on the surface properties of the colloidal particles are not yet fully understood. We provide new interfacial studies on the nonequilibrium dynamics of a colloidal system with tunable surface charge density. We push individual sub-micron colloidal particles towards an oil-water interface and track their motion in three-dimensions using holographic microscopy to examine the influence of zeta potential on the dynamics of the system. This project was funded by the BASF Advanced Research Initiative, BASF SE, Germany.

  11. Thermomorphic phase separation in ionic liquid-organic liquid systems - conductivity and spectroscopic characterization

    DEFF Research Database (Denmark)

    Riisager, Anders; Fehrmann, Rasmus; Berg, Rolf W.;

    2005-01-01

    Electrical conductivity, FT-Raman and NMR measurements are demonstrated as useful tools to probe and determine phase behavior of thermomorphic ionic liquid-organic liquid systems. To illustrate the methods, consecutive conductivity measurements of a thermomorphic methoxyethoxyethyl-imidazolium io......Electrical conductivity, FT-Raman and NMR measurements are demonstrated as useful tools to probe and determine phase behavior of thermomorphic ionic liquid-organic liquid systems. To illustrate the methods, consecutive conductivity measurements of a thermomorphic methoxyethoxyethyl...

  12. Static and dynamic electrowetting of an ionic liquid in a solid/liquid/liquid system.

    Science.gov (United States)

    Paneru, Mani; Priest, Craig; Sedev, Rossen; Ralston, John

    2010-06-23

    A droplet of an ionic liquid (1-butyl-3-methylimidazolium tetrafluoroborate, bmim.BF(4)) is immersed in an immiscible liquid (n-hexadecane) and electrowetted on a flat Teflon AF1600-coated ITO electrode. The static contact angle decreases significantly when voltage is applied between the droplet and the electrode: from 145 degrees down to 50 degrees (with DC voltage) and 15 degrees (with AC voltage). The electrowetting curves (contact angle versus voltage) are similar to the ones obtained in other solid/liquid/vapor and solid/liquid/liquid systems: symmetric with respect to zero voltage and correctly described by Young-Lippmann equation below saturation. The reversibility is excellent and contact angle hysteresis is minimal (approximately 2 degrees). The step size used in applying the DC voltage and the polarity of the voltage are unimportant. The saturation contact angle cannot be predicted with the simple zero-interfacial tension theory. Spreading (after applying a DC voltage) and retraction (after switching off the voltage) of the droplet is monitored. The base area of the droplet varies exponentially during wetting (exponential saturation) and dewetting (exponential decay). The characteristic time is 20 ms for spreading and 35 ms for retraction (such asymmetry is not observed with water-glycerol mixtures of a similar viscosity). The spreading kinetics (dynamic contact angle versus contact line speed) can be described by the hydrodynamic model (Voinov's equation) for small contact angles and by the molecular-kinetic model (Blake's equation) for large contact angles. The role of viscous and molecular dissipation follows the scheme outlined by Brochard-Wyart and de Gennes.

  13. Energy conversion at liquid/liquid interfaces: artificial photosynthetic systems

    Science.gov (United States)

    Volkov, A. G.; Gugeshashvili, M. I.; Deamer, D. W.

    1995-01-01

    This chapter focuses on multielectron reactions in organized assemblies of molecules at the liquid/liquid interface. We describe the thermodynamic and kinetic parameters of such reactions, including the structure of the reaction centers, charge movement along the electron transfer pathways, and the role of electric double layers in artificial photosynthesis. Some examples of artificial photosynthesis at the oil/water interface are considered, including water photooxidation to the molecular oxygen, oxygen photoreduction, photosynthesis of amphiphilic compounds and proton evolution by photochemical processes.

  14. Development of Automotive Liquid Hydrogen Storage Systems

    Science.gov (United States)

    Krainz, G.; Bartlok, G.; Bodner, P.; Casapicola, P.; Doeller, Ch.; Hofmeister, F.; Neubacher, E.; Zieger, A.

    2004-06-01

    Liquid hydrogen (LH2) takes up less storage volume than gas but requires cryogenic vessels. State-of-the-art applications for passenger vehicles consist of double-wall cylindrical tanks that hold a hydrogen storage mass of up to 10 kg. The preferred shell material of the tanks is stainless steel, since it is very resistant against hydrogen brittleness and shows negligible hydrogen permeation. Therefore, the weight of the whole tank system including valves and heat exchanger is more than 100 kg. The space between the inner and outer vessel is mainly used for thermal super-insulation purposes. Several layers of insulation foils and high vacuums of 10-3 Pa reduce the heat entry. The support structures, which keep the inner tank in position to the outer tank, are made of materials with low thermal conductivity, e.g. glass or carbon fiber reinforced plastics. The remaining heat in-leak leads to a boil-off rate of 1 to 3 percent per day. Active cooling systems to increase the stand-by time before evaporation losses occur are being studied. Currently, the production of several liquid hydrogen tanks that fulfill the draft of regulations of the European Integrated Hydrogen Project (EIHP) is being prepared. New concepts of lightweight liquid hydrogen storage tanks will be investigated.

  15. Design of Automatic Control System for Continuous Caster Liquid Level%连铸机液位自动控制系统设计

    Institute of Scientific and Technical Information of China (English)

    邓丽霞; 姜磊; 高生祥

    2012-01-01

    在比较连铸机液位控制系统各组成部分形式和特点的基础上,采用涡流检测技术与步进电动缸技术相结合实现结晶器液位的闭环自动控制.硬件设计上,完成了液位控制系统各组成部分的设计选型.下位机软件设计上,采用PLC自带的PTO输出口控制步进电动缸的位置间接控制进入结晶器的流量,采用成熟的PI控制算法实现液位的闭环控制.%The eddy current detection technology and the stepping electromotion technology were used to realize the closed loop automatic control of mold molten steel level, on the basis of comparing mode and characteristic of each constituent part of the mold level control system. For the hardware design, choice of each constituent part of mold level control system was completed. For the software design of rock - bottom machine, PTO port of PLC was used to control the stepping electric cylinder in order to keep the molten steel level steady, and the mature PI control algorithm was adopted to realize closed loop automatic control of mold molten steel level.

  16. Slug control system; Sistema de controle de golfadas

    Energy Technology Data Exchange (ETDEWEB)

    Borges Filho, Alvaro de Miranda; Meira, Marco Antonio Alves de; Vaz, Celio Eduardo Martins [PETROBRAS, Macae, RJ (Brazil). Unidade de Negocios da Bacia de Campos

    2004-07-01

    Due to the characteristics of flow, gas can separate from oil in the pipelines and risers that link subsea manifolds to production offshore platforms, forming liquid and gas slugs in the production separator. Liquid slugs can cause overflow in the separators. Gas slugs can cause burning in the flare due to the limitation in the turbo-compressors acceleration. In both cases the consequences are loss of production or shut-downs. This paper presents a Slug Control System designed to attenuate severe gas and liquid flow variations. The system consist of a control valve installed in the separator inlet, transmitters, a controller, control algorithm and a monitoring station. This system is operating since October 2003 in a production offshore platform, in Campus Basin, Brazil, with excellent results, reducing the gas burning in 45% without oil production loss. (author)

  17. Cryogenic Liquid Sample Acquisition System for Remote Space Applications

    Science.gov (United States)

    Mahaffy, Paul; Trainer, Melissa; Wegel, Don; Hawk, Douglas; Melek, Tony; Johnson, Christopher; Amato, Michael; Galloway, John

    2013-01-01

    There is a need to acquire autonomously cryogenic hydrocarbon liquid sample from remote planetary locations such as the lakes of Titan for instruments such as mass spectrometers. There are several problems that had to be solved relative to collecting the right amount of cryogenic liquid sample into a warmer spacecraft, such as not allowing the sample to boil off or fractionate too early; controlling the intermediate and final pressures within carefully designed volumes; designing for various particulates and viscosities; designing to thermal, mass, and power-limited spacecraft interfaces; and reducing risk. Prior art inlets for similar instruments in spaceflight were designed primarily for atmospheric gas sampling and are not useful for this front-end application. These cryogenic liquid sample acquisition system designs for remote space applications allow for remote, autonomous, controlled sample collections of a range of challenging cryogenic sample types. The design can control the size of the sample, prevent fractionation, control pressures at various stages, and allow for various liquid sample levels. It is capable of collecting repeated samples autonomously in difficult lowtemperature conditions often found in planetary missions. It is capable of collecting samples for use by instruments from difficult sample types such as cryogenic hydrocarbon (methane, ethane, and propane) mixtures with solid particulates such as found on Titan. The design with a warm actuated valve is compatible with various spacecraft thermal and structural interfaces. The design uses controlled volumes, heaters, inlet and vent tubes, a cryogenic valve seat, inlet screens, temperature and cryogenic liquid sensors, seals, and vents to accomplish its task.

  18. Controllable liquid crystal gratings for an adaptive 2D/3D auto-stereoscopic display

    Science.gov (United States)

    Zhang, Y. A.; Jin, T.; He, L. C.; Chu, Z. H.; Guo, T. L.; Zhou, X. T.; Lin, Z. X.

    2017-02-01

    2D/3D switchable, viewpoint controllable and 2D/3D localizable auto-stereoscopic displays based on controllable liquid crystal gratings are proposed in this work. Using the dual-layer staggered structure on the top substrate and bottom substrate as driven electrodes within a liquid crystal cell, the ratio between transmitting region and shielding region can be selectively controlled by the corresponding driving circuit, which indicates that 2D/3D switch and 3D video sources with different disparity images can reveal in the same auto-stereoscopic display system. Furthermore, the controlled region in the liquid crystal gratings presents 3D model while other regions maintain 2D model in the same auto-stereoscopic display by the corresponding driving circuit. This work demonstrates that the controllable liquid crystal gratings have potential applications in the field of auto-stereoscopic display.

  19. 基于BP神经网络PID算法的水箱液位控制系统设计%Design of liquid level control system of water tank based on BP network PID algorithm

    Institute of Scientific and Technical Information of China (English)

    陈怀忠

    2012-01-01

    针对水箱液位这样一个多干扰、大惯性、高度非线性系统控制性能优化较困难,传统的控制策略在控制精度、灵敏度以及系统稳定性均存在缺陷,充分利用神经网络具有非线性函数逼近能力,构造神经网络PID自整定控制器,在解决高度非线性和严重不确定系统方面具有较好控制能力.解决了传统PID控制算法难以保证系统在任何工况条件下始终具有最佳控制性能的难题.仿真结果表明,该控制能使系统达到较好的控制效果.%For the problem of controlling the liquid level of water tank with multi- interference, large inertia and highly nonlinear, the traditional control strategy has disadvantages in control precision, sensitivity and system stability. BP neural network control makes full use of neural network approximation capability to construct neural network self-tuning PID controller, having better control in resolving the highly nonlinear seriously uncertain systems. It overcomes the shortcoming of traditional PID controller which can not assure optimal control performance for system in any working condition. Simulated result indicates this control is able to make system reach satisfied control effect.

  20. Control System Damps Vibrations

    Science.gov (United States)

    Kopf, E. H., Jr.; Brown, T. K.; Marsh, E. L.

    1983-01-01

    New control system damps vibrations in rotating equipment with help of phase-locked-loop techniques. Vibrational modes are controlled by applying suitable currents to drive motor. Control signals are derived from sensors mounted on equipment.

  1. Controllability of Quantum Systems

    CERN Document Server

    Schirmer, S G; Solomon, A I

    2003-01-01

    An overview and synthesis of results and criteria for open-loop controllability of Hamiltonian quantum systems obtained using Lie group and Lie algebra techniques is presented. Negative results for open-loop controllability of dissipative systems are discussed, and the superiority of closed-loop (feedback) control for quantum systems is established.

  2. Feedback control of flow alignment in sheared liquid crystals.

    Science.gov (United States)

    Strehober, David A; Schöll, Eckehard; Klapp, Sabine H L

    2013-12-01

    Based on a continuum theory, we investigate the manipulation of the nonequilibrium behavior of a sheared liquid crystal via closed-loop feedback control. Our goal is to stabilize a specific dynamical state, that is, the stationary "flow alignment," under conditions where the uncontrolled system displays oscillatory director dynamics with in-plane symmetry. To this end we employ time-delayed feedback control (TDFC), where the equation of motion for the ith component q(i)(t) of the order parameter tensor is supplemented by a control term involving the difference q(i)(t)-q(i)(t-τ). In this diagonal scheme, τ is the delay time. We demonstrate that the TDFC method successfully stabilizes flow alignment for suitable values of the control strength K and τ; these values are determined by solving an exact eigenvalue equation. Moreover, our results show that only small values of K are needed when the system is sheared from an isotropic equilibrium state, contrary to the case where the equilibrium state is nematic.

  3. Kinetics of glycoalkaloid hydrolysis and solanidine extraction in liquid-liquid systems

    Directory of Open Access Journals (Sweden)

    Stanković Mihajlo Z.

    2002-01-01

    Full Text Available The kinetics of glycoalkaloid hydrolysis and solanidine extraction in Analyzed in this study. obtained from dried and milled potato haulm to to which hydrochlotic acid was added is the first liquid phase, while chloroform trichloroethylene or carbon tetrachlondeisthe second organic, liquid phase. The purpose of this paper was to combine the processes of glycoalkaloid hydrolysis to solanidine and solanidine extraction into one step, and to find the optimal liquid-liquid system for such a process.

  4. Systems and methods for analyzing liquids under vacuum

    Science.gov (United States)

    Yu, Xiao-Ying; Yang, Li; Cowin, James P.; Iedema, Martin J.; Zhu, Zihua

    2013-10-15

    Systems and methods for supporting a liquid against a vacuum pressure in a chamber can enable analysis of the liquid surface using vacuum-based chemical analysis instruments. No electrical or fluid connections are required to pass through the chamber walls. The systems can include a reservoir, a pump, and a liquid flow path. The reservoir contains a liquid-phase sample. The pump drives flow of the sample from the reservoir, through the liquid flow path, and back to the reservoir. The flow of the sample is not substantially driven by a differential between pressures inside and outside of the liquid flow path. An aperture in the liquid flow path exposes a stable portion of the liquid-phase sample to the vacuum pressure within the chamber. The radius, or size, of the aperture is less than or equal to a critical value required to support a meniscus of the liquid-phase sample by surface tension.

  5. Compact and Integrated Liquid Bismuth Propellant Feed System

    Science.gov (United States)

    Polzin, Kurt A.; Stanojev, Boris; Korman, Valentin; Gross, Jeffrey T.

    2007-01-01

    Operation of Hall thrusters with bismuth propellant has been shown to be a promising path toward high-power, high-performance, long-lifetime electric propulsion for spaceflight missions [1]. There has been considerable effort in the past three years aimed at resuscitating this promising technology and validating earlier experimental results indicating the advantages of a bismuth-fed Hall thruster. A critical element of the present effort is the precise metering of propellant to the thruster, since performance cannot be accurately assessed without an accurate accounting of mass flow rate. Earlier work used a pre./post-test propellant weighing scheme that did not provide any real-time measurement of mass flow rate while the thruster was firing, and makes subsequent performance calculations difficult. The motivation of the present work is to develop a precision liquid bismuth Propellant Management System (PMS) that provides hot, molten bismuth to the thruster while simultaneously monitoring in real-time the propellant mass flow rate. The system is a derivative of our previous propellant feed system [2], but the present system represents a more compact design. In addition, all control electronics are integrated into a single unit and designed to reside on a thrust stand and operate in the relevant vacuum environment where the thruster is operating, significantly increasing the present technology readiness level of liquid metal propellant feed systems. The design of various critical components in a bismuth PMS are described. These include the bismuth reservoir and pressurization system, 'hotspot' flow sensor, power system and integrated control system. Particular emphasis is given to selection of the electronics employed in this system and the methods that were used to isolate the power and control systems from the high-temperature portions of the feed system and thruster. Open loop calibration test results from the 'hotspot' flow sensor are reported, and results of

  6. Design of Ultrasonic Liquid Level Control System Based on MCU%基于单片机的超声波液位检测系统设计

    Institute of Scientific and Technical Information of China (English)

    鲁可; 张晓东; 马宏旭

    2014-01-01

    为解决腐蚀性液体的液位测量中电极特别容易被电解腐蚀的问题,将超声波技术应用到工业生产液位或物料的检测中。以AT89S52单片机为核心,建立超声波测得距离和声速与传输时间之间的关系,提出通过硬件电路设计和软件编程实现对液位高度的检测的方法,进行了超声波测距在20 cm和80 cm两种距离的试验。由于超声波受温度的影响较大,采用温度传感器对温度进行测量,根据公式进行温度补偿,并设计了报警模块,当温度过高时进行报警。结果表明,超声波测距的相对误差分别为2.5%和1.25%,这样的精度能够满足实际需求,达到了预期目标。该系统具有测量准确、功耗低、使用寿命长等特点,可以满足一般的工业需要。%To solve the problem of the electrode especially vulnerable to electrolytic corrosion in corrosive liquid level measurement, the detection of ultrasonic technology is applied to the industrial production level or materials. Carries out AT89S52 MCU as the core, establishes ultrasonic measurement of relationship between distance and speed and the transmission time, the method of detecting the height of the liquid level is realized by hardware circuit design and software programming, the ultrasonic ranging in the test of 20cm and 80cm two kinds of distance. The ultrasonic influenced by temperature, measure the temperature by temperature sensor, according to the temperature compensation formula, and the design of alarm module, when the temperature is too high. The results show that, the relative error of ultrasonic distance measurement was 2.5%and 1.25% respectively, the accuracy can meet the actual demand, to achieve the expected goal. The system has the characteristics of accurate measurement, low power consumption, long service life, can meet the general needs of industry.

  7. Digital Optical Control System

    Science.gov (United States)

    Jordan, David H.; Tipton, Charles A.; Christmann, Charles E.; Hochhausler, Nils P.

    1988-09-01

    We describe the digital optical control system (DOGS), a state-of-the-art controller for electrical feedback in an optical system. The need for a versatile optical controller arose from a number of unique experiments being performed by the Air Force Weapons Laboratory. These experiments use similar detectors and actuator-controlled mirrors, but the control requirements vary greatly. The experiments have in common a requirement for parallel control systems. The DOGS satisfies these needs by allowing several control systems to occupy a single chassis with one master controller. The architecture was designed to allow upward compatibility with future configurations. Combinations of off-the-shelf and custom boards are configured to meet the requirements of each experiment. The configuration described here was used to control piston error to X/80 at a wavelength of 0.51 Am. A peak sample rate of 8 kHz, yielding a closed loop bandwidth of 800 Hz, was achieved.

  8. Discrete Control Systems

    CERN Document Server

    Lee, Taeyoung; McClamroch, N Harris

    2007-01-01

    Discrete control systems, as considered here, refer to the control theory of discrete-time Lagrangian or Hamiltonian systems. These discrete-time models are based on a discrete variational principle, and are part of the broader field of geometric integration. Geometric integrators are numerical integration methods that preserve geometric properties of continuous systems, such as conservation of the symplectic form, momentum, and energy. They also guarantee that the discrete flow remains on the manifold on which the continuous system evolves, an important property in the case of rigid-body dynamics. In nonlinear control, one typically relies on differential geometric and dynamical systems techniques to prove properties such as stability, controllability, and optimality. More generally, the geometric structure of such systems plays a critical role in the nonlinear analysis of the corresponding control problems. Despite the critical role of geometry and mechanics in the analysis of nonlinear control systems, non...

  9. Thermomorphic phase separation in ionic liquid-organic liquid systems--conductivity and spectroscopic characterization.

    Science.gov (United States)

    Riisager, Anders; Fehrmann, Rasmus; Berg, Rolf W; van Hal, Roy; Wasserscheid, Peter

    2005-08-21

    Electrical conductivity, FT-Raman and NMR measurements are demonstrated as useful tools to probe and determine phase behavior of thermomorphic ionic liquid-organic liquid systems. To illustrate the methods, consecutive conductivity measurements of a thermomorphic methoxyethoxyethyl-imidazolium ionic liquid/1-hexanol system are performed in the temperature interval 25-80 degrees C using a specially constructed double-electrode cell. In addition, FT-Raman and 1H-NMR spectroscopic studies performed on the phase-separable system in the same temperature interval confirm the mutual solubility of the components in the system, the liquid-liquid equilibrium phase diagram of the binary mixture, and signify the importance of hydrogen bonding between the ionic liquid and the hydroxyl group of the alcohol.

  10. ALFA Detector Control System

    CERN Document Server

    Oleiro Seabra, Luis Filipe; The ATLAS collaboration

    2015-01-01

    ALFA (Absolute Luminosity For ATLAS) is one of the sub-detectors of ATLAS/LHC. The ALFA system is composed by two stations installed in the LHC tunnel 240 m away from each side of the ATLAS interaction point. Each station has a vacuum and ventilation system, movement control and all the required electronic for signal processing. The Detector Control System (DCS) provides control and monitoring of several components and ensures the safe operation of the detector contributing to good Data Quality. This paper describes the ALFA DCS system including a detector overview, operation aspects and hardware control through a SCADA system, WinCC OA.

  11. ALFA Detector Control System

    CERN Document Server

    Oleiro Seabra, Luis Filipe; The ATLAS collaboration

    2015-01-01

    ALFA (Absolute Luminosity For ATLAS) is one of the sub-detectors of ATLAS (A Toroidal LHC Apparatus). The ALFA system is composed by four stations installed in the LHC tunnel 240 m away from the ATLAS interaction point. Each station has a vacuum and ventilation system, movement control and all the required electronics for signal processing. The Detector Control System (DCS) provides control and monitoring of several components and ensures the safe operation of the detector contributing to good Data Quality. This paper describes the ALFA DCS system including a detector overview, operation aspects and hardware control through a SCADA system, WinCC OA.

  12. Controllability in nonlinear systems

    Science.gov (United States)

    Hirschorn, R. M.

    1975-01-01

    An explicit expression for the reachable set is obtained for a class of nonlinear systems. This class is described by a chain condition on the Lie algebra of vector fields associated with each nonlinear system. These ideas are used to obtain a generalization of a controllability result for linear systems in the case where multiplicative controls are present.

  13. International Approach to Structuring Liquidity of Banking Systems

    Directory of Open Access Journals (Sweden)

    Makarenko Mykhaylo I.

    2014-03-01

    Full Text Available The goal of the article is analysis of liquidity as a system category and study of essential transformation of liquidity from the purely banking notion to its wider interpretation as a financial system category on the basis of international approaches in this sphere. The article states that the liquidity notion is one of the fundamental ones in the theory of finance and banking business, but, until now, the issue of the nature of liquidity has not been completely developed yet. The article also states that the system nature of liquidity is expressed, in international practice, in availability of interaction of specific forms of its manifestation, such as the Central Bank liquidity (monetary basis of the economy, market liquidity (inter-bank market and asset market and financing liquidity (liquidity of institutional units. In the result of the study the article offers such interpretation of the banking system liquidity as a complex dynamic interaction of such elements as the Central Bank liquidity, liquidity of individual banking institutions and markets (both at national and international levels, which ensures execution of their obligations by banks, easy flow of financial resources and their efficient re-distribution between economic subjects, ensuring continuous general growth of economy.

  14. Motion control systems

    CERN Document Server

    Sabanovic, Asif

    2011-01-01

    "Presents a unified approach to the fundamental issues in motion control, starting from the basics and moving through single degree of freedom and multi-degree of freedom systems In Motion Control Systems, Šabanovic and Ohnishi present a unified approach to very diverse issues covered in motion control systems, offering know-how accumulated through work on very diverse problems into a comprehensive, integrated approach suitable for application in high demanding high-tech products. It covers material from single degree of freedom systems to complex multi-body non-redundant and redundant systems. The discussion of the main subject is based on original research results and will give treatment of the issues in motion control in the framework of the acceleration control method with disturbance rejection technique. This allows consistent unification of different issues in motion control ranging from simple trajectory tracking to topics related to haptics and bilateral control without and with delay in the measure...

  15. Applied Control Systems Design

    CERN Document Server

    Mahmoud, Magdi S

    2012-01-01

    Applied Control System Design examines several methods for building up systems models based on real experimental data from typical industrial processes and incorporating system identification techniques. The text takes a comparative approach to the models derived in this way judging their suitability for use in different systems and under different operational circumstances. A broad spectrum of control methods including various forms of filtering, feedback and feedforward control is applied to the models and the guidelines derived from the closed-loop responses are then composed into a concrete self-tested recipe to serve as a check-list for industrial engineers or control designers. System identification and control design are given equal weight in model derivation and testing to reflect their equality of importance in the proper design and optimization of high-performance control systems. Readers’ assimilation of the material discussed is assisted by the provision of problems and examples. Most of these e...

  16. Control and optimization system

    Science.gov (United States)

    Xinsheng, Lou

    2013-02-12

    A system for optimizing a power plant includes a chemical loop having an input for receiving an input parameter (270) and an output for outputting an output parameter (280), a control system operably connected to the chemical loop and having a multiple controller part (230) comprising a model-free controller. The control system receives the output parameter (280), optimizes the input parameter (270) based on the received output parameter (280), and outputs an optimized input parameter (270) to the input of the chemical loop to control a process of the chemical loop in an optimized manner.

  17. Control systems engineering

    CERN Document Server

    Nise, Norman S

    1995-01-01

    This completely updated new edition shows how to use MATLAB to perform control-system calculations. Designed for the professional or engineering student who needs a quick and readable update on designing control systems, the text features a series of tightly focused examples that clearly illustrate each concept of designing control systems. Most chapters conclude with a detailed application from the two case studies that run throughout the book: an antenna asimuth control system and a submarine. The author also refers to many examples of design methods.

  18. Step Motor Control System

    Institute of Scientific and Technical Information of China (English)

    ZhangShuochengt; WangDan; QiaoWeimin; JingLan

    2003-01-01

    All kinds of step motors and servomotors are widely used in CSR control system, such as many vacuum valves control that set on the HIRFL-CSR; all kinds of electric switches and knobs of ECR Ion Source; equipment of CSR Beam Diagnostics and a lot of large equipment like Inside Gun Toroid and Collector Toroid of HIRFL. A typical control system include up to 32 16-I/O Control boards, and each 16-I/O Control board can control 4 motors at the same time (including 8 Limit Switches).

  19. Evaluation of Mechanical Ventilator Use with Liquid Oxygen Systems

    Science.gov (United States)

    2017-02-22

    AFRL-SA-WP-SR-2017-0006 Evaluation of Mechanical Ventilator Use with Liquid Oxygen Systems Thomas Blakeman, MSc, RRT; Dario...To) August 2014 – September 2016 4. TITLE AND SUBTITLE Evaluation of Mechanical Ventilator Use with Liquid Oxygen Systems 5a. CONTRACT NUMBER...Cleared, 88PA, Case # 2016-6491, 16 Dec 2016. 14. ABSTRACT Mechanical ventilators coupled with portable liquid oxygen (LOX) systems are critical

  20. dc power control for a liquid-fed resistojet

    Science.gov (United States)

    Gruber, Robert P.

    1988-01-01

    A simple breadboard power controller was designed and demonstrated for a new liquid-fed water resistojet. The 1-piece laboratory model thruster has an integrated vaporizer/superheater using a single heating element. Heater temperature was maintained at or near a preset reference value with the closed loop controller providing pulse width modulated (PWM) dc power into the thruster heater. A combined thruster, temperature readout, PWM transfer function was experimentally determined. This transfer function was used to design a proportional plus integral controller that demonstrated zero steady state error, conservative stability margins and adequate transient response to step changes in propellant flow rate, input voltage and temperature reference. Initial turn-on temperature overshoot from room temperature to a 650 C setpoint was 80 C. In addition, EMI was alleviated by reducing heater dI/dt and dV/dt using a simple diode-inductor-capacitor network. Based on limited initial tests, thruster preheat with no propellant flow was necessary to achieve stable system operation during startup. Breadboard power efficiency was 99 percent at 1 kW, and component mass was 0.4 kg excluding the power loss and mass of an input filter required for spacecraft integration.

  1. The dc power control for a liquid-fed resistojet

    Science.gov (United States)

    Gruber, Robert P.

    1988-01-01

    A simple breadboard power controller was designed and demonstrated for a new liquid-fed water resistojet. The 1-piece laboratory model thruster has an integrated vaporizer/superheater using a single heating element. Heater temperature was maintained at or near a preset reference value with the closed loop controller providing pulse width modulated (PWM) dc power into the thruster heater. A combined thruster, temperature readout, PWM transfer function was experimentally determined. This transfer function was used to design a proportional plus integral controller that demonstrated zero steady state error, conservative stability margins and adequate transient response to step changes in propellant flow rate, input voltage and temperature reference. Initial turn-on temperature overshoot from room temperature to a 650 C setpoint was 80 C. In addition, EMI was alleviated by reducing heater dI/dt and dV/dt using a simple diode-inductor-capacitor network. Based on limited initial tests, thruster preheat with no propellant flow was necessary to achieve stable system operation during startup. Breadboard power efficiency was 99 percent at 1 kW, and component mass was 0.4 kg excluding the power loss and mass of an input filter required for spacecraft integration.

  2. Modeling leaks from liquid hydrogen storage systems.

    Energy Technology Data Exchange (ETDEWEB)

    Winters, William Stanley, Jr.

    2009-01-01

    This report documents a series of models for describing intended and unintended discharges from liquid hydrogen storage systems. Typically these systems store hydrogen in the saturated state at approximately five to ten atmospheres. Some of models discussed here are equilibrium-based models that make use of the NIST thermodynamic models to specify the states of multiphase hydrogen and air-hydrogen mixtures. Two types of discharges are considered: slow leaks where hydrogen enters the ambient at atmospheric pressure and fast leaks where the hydrogen flow is usually choked and expands into the ambient through an underexpanded jet. In order to avoid the complexities of supersonic flow, a single Mach disk model is proposed for fast leaks that are choked. The velocity and state of hydrogen downstream of the Mach disk leads to a more tractable subsonic boundary condition. However, the hydrogen temperature exiting all leaks (fast or slow, from saturated liquid or saturated vapor) is approximately 20.4 K. At these temperatures, any entrained air would likely condense or even freeze leading to an air-hydrogen mixture that cannot be characterized by the REFPROP subroutines. For this reason a plug flow entrainment model is proposed to treat a short zone of initial entrainment and heating. The model predicts the quantity of entrained air required to bring the air-hydrogen mixture to a temperature of approximately 65 K at one atmosphere. At this temperature the mixture can be treated as a mixture of ideal gases and is much more amenable to modeling with Gaussian entrainment models and CFD codes. A Gaussian entrainment model is formulated to predict the trajectory and properties of a cold hydrogen jet leaking into ambient air. The model shows that similarity between two jets depends on the densimetric Froude number, density ratio and initial hydrogen concentration.

  3. Design of an Automatic Two-dimensional Liquid Chromatograph Control System%全自动二维液相色谱仪控制系统的设计

    Institute of Scientific and Technical Information of China (English)

    常剑; 罗飞

    2011-01-01

    Based on the theory of two-dimensional chromatogram the liquid chromatograph employs two chromatographic columns to gradually separate substances, and thus solves the challenge of separating natural substances in traditional Chinese medicine.Firstly the structure of the two-dimensional liquid chromatograph is introduced, then two methods for controlling stream paths and separating substances, on-line separating and off-line separating are discussed in details.And then the design for controlling the stream paths is illustrated which is aimed at the realization of time-sharing control of various valves and the realization of separating substances and steady operating of systems in different separating ways.And in the substance collecting step, an algorithm is adopted for the analysis of chromatogram wave.As is shown by the result, the system can collect substances efficiently.%二维液相色谱仪根据二维液相色谱的原理,采用两根色谱柱逐步分离,解决了中药中天然物质分离难度大的问题.本文首先介绍了二维液相色谱仪控制系统的架构,接着讨论了整体流路及分离的两种工作方法:在线工作方式和离线工作方式.然后设计控制流路实现对各种阀门的分时控制,以实现不同分离方法下的系统运行及物质分离.在最后收集阶段,采用一种算法对色谱波峰进行分析,实现有效收集.

  4. Discrete control systems

    CERN Document Server

    Okuyama, Yoshifumi

    2014-01-01

    Discrete Control Systems establishes a basis for the analysis and design of discretized/quantized control systemsfor continuous physical systems. Beginning with the necessary mathematical foundations and system-model descriptions, the text moves on to derive a robust stability condition. To keep a practical perspective on the uncertain physical systems considered, most of the methods treated are carried out in the frequency domain. As part of the design procedure, modified Nyquist–Hall and Nichols diagrams are presented and discretized proportional–integral–derivative control schemes are reconsidered. Schemes for model-reference feedback and discrete-type observers are proposed. Although single-loop feedback systems form the core of the text, some consideration is given to multiple loops and nonlinearities. The robust control performance and stability of interval systems (with multiple uncertainties) are outlined. Finally, the monograph describes the relationship between feedback-control and discrete ev...

  5. Compact electrically controlled broadband liquid crystal photonic bandgap fiber polarizer

    DEFF Research Database (Denmark)

    Wei, Lei; Alkeskjold, Thomas Tanggaard; Bjarklev, Anders Overgaard

    2009-01-01

    An electrically controlled liquid crystal photonic-bandgap fiber polarizer is experimentally demonstrated. A maximum 21.3dB electrically tunable polarization extinction ratio is achieved with 45° rotatable transmission axis as well as switched on and off in 1300nm–1600nm.......An electrically controlled liquid crystal photonic-bandgap fiber polarizer is experimentally demonstrated. A maximum 21.3dB electrically tunable polarization extinction ratio is achieved with 45° rotatable transmission axis as well as switched on and off in 1300nm–1600nm....

  6. Control system design guide

    Energy Technology Data Exchange (ETDEWEB)

    Sellers, David; Friedman, Hannah; Haasl, Tudi; Bourassa, Norman; Piette, Mary Ann

    2003-05-01

    The ''Control System Design Guide'' (Design Guide) provides methods and recommendations for the control system design process and control point selection and installation. Control systems are often the most problematic system in a building. A good design process that takes into account maintenance, operation, and commissioning can lead to a smoothly operating and efficient building. To this end, the Design Guide provides a toolbox of templates for improving control system design and specification. HVAC designers are the primary audience for the Design Guide. The control design process it presents will help produce well-designed control systems that achieve efficient and robust operation. The spreadsheet examples for control valve schedules, damper schedules, and points lists can streamline the use of the control system design concepts set forth in the Design Guide by providing convenient starting points from which designers can build. Although each reader brings their own unique questions to the text, the Design Guide contains information that designers, commissioning providers, operators, and owners will find useful.

  7. Controllability of Discontinuous Systems

    OpenAIRE

    Veliov, V. M.; Krastanov, M.

    1988-01-01

    This report presents an approach to the local controllability problem for a discontinuous system. The approach is based on a concept of tangent vector field to a generalized dynamic system, which makes possible the differential geometry tools to be applied in the discontinuous case. Sufficient controllability conditions are derived.

  8. Spacecraft momentum control systems

    CERN Document Server

    Leve, Frederick A; Peck, Mason A

    2015-01-01

    The goal of this book is to serve both as a practical technical reference and a resource for gaining a fuller understanding of the state of the art of spacecraft momentum control systems, specifically looking at control moment gyroscopes (CMGs). As a result, the subject matter includes theory, technology, and systems engineering. The authors combine material on system-level architecture of spacecraft that feature momentum-control systems with material about the momentum-control hardware and software. This also encompasses material on the theoretical and algorithmic approaches to the control of space vehicles with CMGs. In essence, CMGs are the attitude-control actuators that make contemporary highly agile spacecraft possible. The rise of commercial Earth imaging, the advances in privately built spacecraft (including small satellites), and the growing popularity of the subject matter in academic circles over the past decade argues that now is the time for an in-depth treatment of the topic. CMGs are augmented ...

  9. Liquid metal flow control by DC electromagnetic pumps; Controle de vazao de metais liquidos por bombas eletromagneticas de corrente continua

    Energy Technology Data Exchange (ETDEWEB)

    Borges, Eduardo Madeira; Braz Filho, Francisco Antonio; Guimaraes, Lamartine Nogueira Frutuoso [Instituto de Estudos Avancados (IEAv), Sao Jose dos Campos, SP (Brazil)], e-mail: eduardo@ieav.cta.br, e-mail: fbraz@ieav.cta.br, e-mail: guimarae@ieav.cta.br

    2006-07-01

    The cooling system of high-density thermal power requires fluids of high thermal conductivity, such as liquid metals. Electromagnetic pumps can be used to liquid metal fluid flow control in cooling circuits. The operation of electromagnetic pumps used to flow control is based on Lorentz force. This force can be achieved by magnetic field and electric current interaction, controlled by external independent power supplies. This work presents the electromagnetic pump operational principles, the IEAv development scheme and the BEMC-1 simulation code. The theoretical results of BEMC-1 simulation are compared to electromagnetic pump operation experimental data, validating the BEMC-1 code. This code is used to evaluate the DC electromagnetic pump performance applied to Mercury flow control and others liquid metal such as Sodium, Lead and Bismuth, used in nuclear fast reactors. (author)

  10. Drone Control System

    Science.gov (United States)

    1983-01-01

    Drones, subscale vehicles like the Firebees, and full scale retired military aircraft are used to test air defense missile systems. The DFCS (Drone Formation Control System) computer, developed by IBM (International Business Machines) Federal Systems Division, can track ten drones at once. A program called ORACLS is used to generate software to track and control Drones. It was originally developed by Langley and supplied by COSMIC (Computer Software Management and Information Center). The program saved the company both time and money.

  11. Thermomorphic phase separation in ionic liquid-organic liquid systems - conductivity and spectroscopic characterization

    DEFF Research Database (Denmark)

    Riisager, Anders; Fehrmann, Rasmus; Berg, Rolf W.

    2005-01-01

    Electrical conductivity, FT-Raman and NMR measurements are demonstrated as useful tools to probe and determine phase behavior of thermomorphic ionic liquid-organic liquid systems. To illustrate the methods, consecutive conductivity measurements of a thermomorphic methoxyethoxyethyl-imidazolium io...... of the components in the system, the liquid-liquid equilibrium phase diagram of the binary mixture, and signify the importance of hydrogen bonding between the ionic liquid and the hydroxyl group of the alcohol.......Electrical conductivity, FT-Raman and NMR measurements are demonstrated as useful tools to probe and determine phase behavior of thermomorphic ionic liquid-organic liquid systems. To illustrate the methods, consecutive conductivity measurements of a thermomorphic methoxyethoxyethyl......-imidazolium ionic liquid/1-hexanol system are performed in the temperature interval 25-80 degrees C using a specially constructed double-electrode cell. In addition, FT-Raman and H-1-NMR spectroscopic studies performed on the phase-separable system in the same temperature interval confirm the mutual solubility...

  12. HYBRID VEHICLE CONTROL SYSTEM

    Directory of Open Access Journals (Sweden)

    V. Dvadnenko

    2016-06-01

    Full Text Available The hybrid vehicle control system includes a start–stop system for an internal combustion engine. The system works in a hybrid mode and normal vehicle operation. To simplify the start–stop system, there were user new possibilities of a hybrid car, which appeared after the conversion. Results of the circuit design of the proposed system of basic blocks are analyzed.

  13. Common Control System Vulnerability

    Energy Technology Data Exchange (ETDEWEB)

    Trent Nelson

    2005-12-01

    The Control Systems Security Program and other programs within the Idaho National Laboratory have discovered a vulnerability common to control systems in all sectors that allows an attacker to penetrate most control systems, spoof the operator, and gain full control of targeted system elements. This vulnerability has been identified on several systems that have been evaluated at INL, and in each case a 100% success rate of completing the attack paths that lead to full system compromise was observed. Since these systems are employed in multiple critical infrastructure sectors, this vulnerability is deemed common to control systems in all sectors. Modern control systems architectures can be considered analogous to today's information networks, and as such are usually approached by attackers using a common attack methodology to penetrate deeper and deeper into the network. This approach often is composed of several phases, including gaining access to the control network, reconnaissance, profiling of vulnerabilities, launching attacks, escalating privilege, maintaining access, and obscuring or removing information that indicates that an intruder was on the system. With irrefutable proof that an external attack can lead to a compromise of a computing resource on the organization's business local area network (LAN), access to the control network is usually considered the first phase in the attack plan. Once the attacker gains access to the control network through direct connections and/or the business LAN, the second phase of reconnaissance begins with traffic analysis within the control domain. Thus, the communications between the workstations and the field device controllers can be monitored and evaluated, allowing an attacker to capture, analyze, and evaluate the commands sent among the control equipment. Through manipulation of the communication protocols of control systems (a process generally referred to as ''reverse engineering''), an

  14. Applications of Fuzzy adaptive PID control in the thermal power plant denitration liquid ammonia evaporation

    Directory of Open Access Journals (Sweden)

    Li Jing

    2016-01-01

    Full Text Available For the control of the liquid level of liquid ammonia in thermal power plant’s ammonia vaporization room, traditional PID controller parameter tuning is difficult to adapt to complex control systems, the setting of the traditional PID controller parameters is difficult to adapt to the complex control system. For the disadvantage of bad parameter setting, poor performance and so on the fuzzy adaptive PID control is proposed. Fuzzy adaptive PID control combines the advantages of traditional PID technology and fuzzy control. By using the fuzzy controller to intelligent control the object, the performance of the PID controller is further improved, and the control precision of the system is improved[1]. The simulation results show that the fuzzy adaptive PID controller not only has the advantages of high accuracy of PID controller, but also has the characteristics of fast and strong adaptability of fuzzy controller. It realizes the optimization of PID parameters which are in the optimal state, and the maximum increase production efficiency, so that are more suitable for nonlinear dynamic system.

  15. Electrical control of Faraday rotation at a liquid-liquid interface.

    Science.gov (United States)

    Marinescu, Monica; Kornyshev, Alexei A; Flatté, Michael E

    2015-01-01

    A theory is developed for the Faraday rotation of light from a monolayer of charged magnetic nanoparticles at an electrified liquid-liquid interface. The polarization fields of neighboring nanoparticles enhance the Faraday rotation. At such interfaces, and for realistic sizes and charges of nanoparticles, their adsorption-desorption can be controlled with a voltage variationFaraday rotation. A calculation based on the Maxwell-Garnett theory predicts that the corresponding redistribution of 40 nm nanoparticles of yttrium iron garnet can switch a cavity with a quality factor larger than 10(4) for light of wavelength 500 nm at normal incidence.

  16. Digital flight control systems

    Science.gov (United States)

    Caglayan, A. K.; Vanlandingham, H. F.

    1977-01-01

    The design of stable feedback control laws for sampled-data systems with variable rate sampling was investigated. These types of sampled-data systems arise naturally in digital flight control systems which use digital actuators where it is desirable to decrease the number of control computer output commands in order to save wear and tear of the associated equipment. The design of aircraft control systems which are optimally tolerant of sensor and actuator failures was also studied. Detection of the failed sensor or actuator must be resolved and if the estimate of the state is used in the control law, then it is also desirable to have an estimator which will give the optimal state estimate even under the failed conditions.

  17. 基于云模型的水箱液位控制系统的设计与实现%Design and Realization of a Tank Liquid Lever Control System Based on the Cloud Model

    Institute of Scientific and Technical Information of China (English)

    李众; 李军; 王海波

    2012-01-01

    A tank liquid lever control system based on cloud model is designed and implemented. The site part of the A3000 process control systerm as the hardware platform, hybrid programming of VB and Matlab achieving the software, the Kingview collecting and displaying date, DDE transforming date are used. In the absence of establish the precise mathematical model of the case, the effect and the robustness of the cloud model controller to are veri-fyed. The experimental results on cloud model theory research as well as industrial control field has certain reference significance.%设计并实现了水箱水位的云模型控制系统.以A3000过程控制系统的现场部分为硬件平台,软件采用VB与Matlab的混合编程,组态采集数据及数据显示.数据传输方式采用DDE通讯技术.验证了云模型控制器在没有建立精确数学模型的情况下的控制效果.验证了云模型控制器的鲁棒性.实验结果对云模型的理论研究以及工业控制现场具有一定的参考意义.

  18. Control Oriented System Identification

    Science.gov (United States)

    1993-08-01

    The research goals for this grant were to obtain algorithms for control oriented system identification is to construct dynamical models of systems...and measured information. Algorithms for this type of nonlinear system identification have been given that produce models suitable for gain scheduled

  19. Dual-beam laser autofocusing system based on liquid lens

    Science.gov (United States)

    Zhang, Fumin; Yao, Yannan; Qu, Xinghua; Zhang, Tong; Pei, Bing

    2017-02-01

    A dual-beam laser autofocusing system is designed in this paper. The autofocusing system is based on a liquid lens with less moving parts and fast response time, which makes the system simple, reliable, compact and fast. A novel scheme "Time-sharing focus, fast conversion" is innovatively proposed. The scheme effectively solves the problem that the guiding laser and the working laser cannot focus at the same target point because of the existence of chromatic aberration. This scheme not only makes both guiding laser and working laser achieve optimal focusing in guiding stage and working stage respectively, but also greatly reduces the system complexity and simplifies the focusing process as well as makes autofocusing time of the working laser reduce to about 10 ms. In the distance range of 1 m to 30 m, the autofocusing spot size is kept under 4.3 mm at 30 m and just 0.18 mm at 1 m. The spot size is much less influenced by the target distance compared with the collimated laser with a micro divergence angle for its self-adaptivity. The dual-beam laser autofocusing system based on liquid lens is fully automatic, compact and efficient. It is fully meet the need of dynamicity and adaptivity and it will play an important role in a number of long-range control applications.

  20. Bioinspired Hand-Operated Smart-Wetting Systems Using Smooth Liquid Coatings.

    Science.gov (United States)

    Tenjimbayashi, Mizuki; Matsubayashi, Takeshi; Moriya, Takeo; Shiratori, Seimei

    2017-07-06

    Manually controllable "hand-operated" smart systems have been developed in many fields, including smart wetting materials, electronic devices, molecular machines, and drug delivery systems. Because complex morphological or chemical control are generally required, versatile strategies for constructing the system are technologically important. Inspired by the natural phenomenon of raindrops rarely bouncing and usually spreading on a puddle, we introduce a droplet-impact-triggering smart-wetting system using "non-smart" smooth liquid coating materials. Changing the droplet impact energy by changing the volume or casting height causes the droplet to completely bounce or spread on the liquid surface, regardless of the miscibility between the two liquids, owing to the stability of air layer. As the bouncing of a droplet on a liquid interface is not usually observed during wetting, we first analyze how the droplet bounces, then prove that the wettability is triggered by the droplet's impact energy, and finally introduce some applications using this system.

  1. FORCES AND MOMENTS OF THE LIQUID FINITE AMPLITUDE SLOSHING IN A LIQUID-SOLID COUPLED SYSTEM

    Institute of Scientific and Technical Information of China (English)

    苟兴宇; 李铁寿; 马兴瑞; 王本利

    2001-01-01

    Nonlinear coupling dynamics between a spring-mass system and a finite amplitude sloshing system with liquid in a cylindrical tank is investigated. Based on a group of nonlinear coupling equations of six degrees of freedoms, analytical formulae of forces and moments of the liquid large amplitude sloshing were obtained. Nonlinearity of the forces and moments of the sloshing was induced by integrating on final configuration of liquid sloshing and the nonlinear terms in the liquid pressure formula. The symmetry between the formula of Ox and Oy direction proves that the derivation is correct. According to the coupled mechanism, the formulae are available in other liquid-solid coupled systems.Simulations and corresponding experimental results arecompared. It is shown that the forces and moments formulae by integrating on the final sloshing configuration are more reasonable. The omitted high-dimensional modal bases and high-order nonlinear terms and the complexity of sloshing damping are main sources of errors.

  2. IGISOL control system modernization

    Energy Technology Data Exchange (ETDEWEB)

    Koponen, J., E-mail: jukka.ae.koponen@jyu.fi; Hakala, J.

    2016-06-01

    Since 2010, the IGISOL research facility at the Accelerator laboratory of the University of Jyväskylä has gone through major changes. Comparing the new IGISOL4 facility to the former IGISOL3 setup, the size of the facility has more than doubled, the length of the ion transport line has grown to about 50 m with several measurement setups and extension capabilities, and the accelerated ions can be fed to the facility from two different cyclotrons. The facility has evolved to a system comprising hundreds of manual, pneumatic and electronic devices. These changes have prompted the need to modernize also the facility control system taking care of monitoring and transporting the ion beams. In addition, the control system is also used for some scientific data acquisition tasks. Basic guidelines for the IGISOL control system update have been remote control, safety, usability, reliability and maintainability. Legacy components have had a major significance in the control system hardware and for the renewed control system software the Experimental Physics and Industrial Control System (EPICS) has been chosen as the architectural backbone.

  3. Load Control System Reliability

    Energy Technology Data Exchange (ETDEWEB)

    Trudnowski, Daniel [Montana Tech of the Univ. of Montana, Butte, MT (United States)

    2015-04-03

    This report summarizes the results of the Load Control System Reliability project (DOE Award DE-FC26-06NT42750). The original grant was awarded to Montana Tech April 2006. Follow-on DOE awards and expansions to the project scope occurred August 2007, January 2009, April 2011, and April 2013. In addition to the DOE monies, the project also consisted of matching funds from the states of Montana and Wyoming. Project participants included Montana Tech; the University of Wyoming; Montana State University; NorthWestern Energy, Inc., and MSE. Research focused on two areas: real-time power-system load control methodologies; and, power-system measurement-based stability-assessment operation and control tools. The majority of effort was focused on area 2. Results from the research includes: development of fundamental power-system dynamic concepts, control schemes, and signal-processing algorithms; many papers (including two prize papers) in leading journals and conferences and leadership of IEEE activities; one patent; participation in major actual-system testing in the western North American power system; prototype power-system operation and control software installed and tested at three major North American control centers; and, the incubation of a new commercial-grade operation and control software tool. Work under this grant certainly supported the DOE-OE goals in the area of “Real Time Grid Reliability Management.”

  4. Liquid-crystal intraocular adaptive lens with wireless control.

    Science.gov (United States)

    Simonov, Aleksey N; Vdovin, Gleb; Loktev, Mikhail

    2007-06-11

    We present a prototype of an adaptive intraocular lens based on a modal liquid-crystal spatial phase modulator with wireless control. The modal corrector consists of a nematic liquid-crystal layer sandwiched between two glass substrates with transparent low- and high-ohmic electrodes, respectively. Adaptive correction of ocular aberrations is achieved by changing the amplitude and the frequency of the applied control voltage. The convex-shaped glass substrates provide the required initial focusing power of the lens. A loop antenna mounded on the rim of the lens delivers an amplitude-modulated radio-frequency control signal to the integrated rectifier circuit that drives the liquid-crystal modal corrector. In vitro measurements of a 5-mm clear aperture prototype with an initial focusing power of +12.5 diopter, remotely driven by a radio-frequency control unit at ~6 MHz, were carried out using a Shack-Hartmann wavefront sensor. The lens based on a 40-mum thick liquid-crystal layer allows for an adjustable defocus of 4 waves, i. e. an accommodation of ~2.51 dioptres at a wavelength of 534 nm, and correction of spherical aberration coefficient ranging from -0.8 to 0.67 waves. Frequency-switching technique was employed to increase the response speed and eliminate transient overshoots in aberration coefficients. The full-scale settling time of the adaptive modal corrector was measured to be ~4 s.

  5. Flow Induced Electrification of Liquid Insulated Systems.

    Science.gov (United States)

    Washabaugh, Andrew Patrick

    1995-01-01

    The transport or motion of semi-insulating liquids has led to flow induced static electrification and catastrophic failures in several industries. While techniques for reducing the hazard have been developed, the roles of seemingly important parameters are poorly understood. The objective of this thesis was to measure and understand the fundamental parameters of the flow electrification process that, together with the laws of electroquasistatics and physicochemical hydrodynamics, can be used to predict the performance of complex flow systems, with particular attention to transformer applications. A rotating cylindrical electrode apparatus, which provided cylindrical Couette flow, was used to simulate flow electrification in an electric power transformer. The apparatus had Shell Diala A transformer oil filling the annulus between coaxial cylindrical stainless steel electrodes that were either bare metal, or covered by a thin copper sheet and/or EHV-Weidmann HiVal pressboard insulation. Extensive experiments characterized the time transient and steady state behavior of the electrification through measurements of the volume charge density, the terminal voltage, and the terminal current as the system was driven out of equilibrium by changes in the flow rate (inner cylinder rotation rates of 100-1400 rpm, Reynolds numbers of 5 times 10^3-5 times 10^5), temperature (15-70 ^circ), insulation moisture content (0.5-20 ppm in the oil), applied voltage (0-2 kV DC), and concentration of the non-ionizable anti-static additive 1,2,3 benzotriazole (BTA, 0-60 ppm). Generally, the electrification increased with flow rate and temperature but the BTA appeared to cause competing effects: it decreased the volume charge density on the liquid side of the interface (by a factor of 4), which reduces the electrification, but also decreased the oil conductivity (by a factor of 10), which enhances the electrification. A critical oil BTA concentration of 5 -8 ppm minimized the electrification

  6. Development of a fast thermal response microfluidic system using liquid metal

    Science.gov (United States)

    Gao, Meng; Gui, Lin

    2016-07-01

    Room temperature liquid metal gallium alloy has been widely used in many micro-electromechanical systems applications, such as on-chip electrical microheaters, micro temperature sensors, micro pumps and so on. Injecting liquid metal into microchannels can provide a simple, rapid, low-cost but efficient way to integrate these elements in microfluidic chips with high accuracy. The liquid metal-filled microstructures can be designed in any shape and easily integrated into microfluidic chips. In this paper, an on-chip liquid metal-based thermal microfluidic system is proposed for quick temperature control at the microscale. The micro system utilizes just one microfluidic chip as a basic working platform, which has liquid metal-based on-chip heaters, temperature sensors and electroosmotic flow pumps. Under the comprehensive control of these elements, the micro system can quickly change the temperature of a target fluid in the microfluidic chip. These liquid metal-based on-chip elements are very helpful for the fabrication and miniaturization of the microfluidic chip. In this paper, deionized water is used to test the temperature control performance of the thermal microfluidic system. According to the experimental results, the micro system can efficiently control the temperature of water ranging from 28 °C to 90 °C. The thermal microfluidic system has great potential for use in many microfluidic applications, such as on-chip polymerase chain reaction, temperature gradient focusing, protein crystallization and chemical synthesis.

  7. ISTTOK control system upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, Ivo S., E-mail: ivoc@ipfn.ist.utl.pt; Duarte, Paulo; Fernandes, Horácio; Valcárcel, Daniel F.; Carvalho, Pedro J.; Silva, Carlos; Duarte, André S.; Neto, André; Sousa, Jorge; Batista, António J.N.; Carvalho, Bernardo B.

    2013-10-15

    Highlights: •ISTTOK fast controller. •All real-time diagnostic and actuators were integrated in the control platform. •100 μs control cycle under the MARTe framework. •The ISTTOK control system upgrade provides reliable operation with an improved operational space. -- Abstract: The ISTTOK tokamak (Ip = 4 kA, BT = 0.5 T, R = 0.46 m, a = 0.085 m) is one of the few tokamaks with regular alternate plasma current (AC) discharges scientific programme. In order to improve the discharge stability and to increase the number of AC discharge cycles a novel control system was developed. The controller acquires data from 50 analog-to-digital converter (ADC) channels of real-time diagnostics and measurements: tomography, Mirnov coils, interferometer, electric probes, sine and cosine probes, bolometer, current delivered by the power supplies, loop voltage and plasma current. The system has a control cycle of 100 μs during which it reads all the diagnostics connected to the advanced telecommunications computing architecture (ATCA) digitizers and sends the control reference to ISTTOK actuators. The controller algorithms are executed on an Intel{sup ®} Q8200 chip with 4 cores running at 2.33 GHz and connected to the I/O interfaces through an ATCA based environment. The real-time control system was programmed in C++ on top of the Multi-threaded Application Real-Time executor (MARTe). To extend the duration of the AC discharges and the plasma stability a new magnetising field power supply was commissioned and the horizontal and vertical field power supplies were also upgraded. The new system also features a user-friendly interface based on HyperText Markup Language (HTML) and Javascript to configure the controller parameters. This paper presents the ISTTOK control system and the consequent update of real-time diagnostics and actuators.

  8. Systemic liquidity risk: a European approach

    NARCIS (Netherlands)

    Perotti, E.

    2011-01-01

    How should financial regulators address problems stemming from liquidity risk? This column argues that the liquidity coverage and net funding ratios proposed for Basel III are economically and politically impractical. It recommends using those ratios as long-term targets while imposing ‘prudential r

  9. Liquid-Liquid Phase Transition and Glass Transition in a Monoatomic Model System

    Directory of Open Access Journals (Sweden)

    Nicolas Giovambattista

    2010-12-01

    Full Text Available We review our recent study on the polyamorphism of the liquid and glass states in a monatomic system, a two-scale spherical-symmetric Jagla model with both attractive and repulsive interactions. This potential with a parametrization for which crystallization can be avoided and both the glass transition and the liquid-liquid phase transition are clearly separated, displays water-like anomalies as well as polyamorphism in both liquid and glassy states, providing a unique opportunity to study the interplay between the liquid-liquid phase transition and the glass transition. Our study on a simple model may be useful in understanding recent studies of polyamorphism in metallic glasses.

  10. Separating closely resembling steroids with ionic liquids in liquid-liquid extraction systems

    NARCIS (Netherlands)

    Vitasari, C.R.; Gramblicka, M.; Gibcus, K.; Visser, T.J.; Geertman, R.M.; Schuur, B.

    2015-01-01

    Separation of steroids by liquid–liquid extraction with ionic liquids (ILs) as solvent was studied both experimentally and by simulation using a model mixture of progesterone and pregnenolone. The studies involved a solvent screening using COSMO-RS software for estimation of progesterone solubility.

  11. A Historical Systems Study of Liquid Rocket Engine Throttling Capabilities

    Science.gov (United States)

    Betts, Erin M.; Frederick, Robert A., Jr.

    2010-01-01

    This is a comprehensive systems study to examine and evaluate throttling capabilities of liquid rocket engines. The focus of this study is on engine components, and how the interactions of these components are considered for throttling applications. First, an assessment of space mission requirements is performed to determine what applications require engine throttling. A background on liquid rocket engine throttling is provided, along with the basic equations that are used to predict performance. Three engines are discussed that have successfully demonstrated throttling. Next, the engine system is broken down into components to discuss special considerations that need to be made for engine throttling. This study focuses on liquid rocket engines that have demonstrated operational capability on American space launch vehicles, starting with the Apollo vehicle engines and ending with current technology demonstrations. Both deep throttling and shallow throttling engines are discussed. Boost and sustainer engines have demonstrated throttling from 17% to 100% thrust, while upper stage and lunar lander engines have demonstrated throttling in excess of 10% to 100% thrust. The key difficulty in throttling liquid rocket engines is maintaining an adequate pressure drop across the injector, which is necessary to provide propellant atomization and mixing. For the combustion chamber, cooling can be an issue at low thrust levels. For turbomachinery, the primary considerations are to avoid cavitation, stall, surge, and to consider bearing leakage flows, rotordynamics, and structural dynamics. For valves, it is necessary to design valves and actuators that can achieve accurate flow control at all thrust levels. It is also important to assess the amount of nozzle flow separation that can be tolerated at low thrust levels for ground testing.

  12. Liquidity Risk and its Management in Lithuanian Banking System

    Directory of Open Access Journals (Sweden)

    Erika Bareikaitė

    2014-04-01

    Full Text Available Banks are the main part of financial sector in each economy and strength of banking system becomes vital for ensuringfavourable economic stability and growth. Recent failure of two commercial banks in Lithuania showed that managershaven’t evaluated liquidity risk or haven’t dealt with it properly. The tasks of the paper are to investigate Lithuanian banksposition towards liquidity risk, analyse what kind of management tools banks use for ensuring favourable position towardsliquidity and to explore the liquidity influence to profitability in Lithuanian banking sector. The article examines liquidity andits management processes in Lithuanian banking sector. Description of liquidity importance is presented. Liquidity risk and itsmeasurement as well as the ways of managing the above mentioned risk is analysed in the article. In order to analyse the relationshipbetween liquidity risk and profitability of banks, analysis of scientific literature, research synthesis and generalizationshave been made.

  13. Gas-Liquid Interfacial Non-Equilibrium Plasmas for Structure Controlled Nanoparticles

    Science.gov (United States)

    Kaneko, Toshiro

    2013-10-01

    Plasmas generated in liquid or in contact with liquid have attracted much attention as a novel reactive field in the nano-bio material creation because the brand-new chemical and biological reactions are yielded at the gas-liquid interface, which are induced by the physical actions of the non-equilibrium plasmas. In this study, first, size- and structure-controlled gold nanoparticles (AuNPs) covered with DNA are synthesized using a pulse-driven gas-liquid interfacial discharge plasma (GLIDP) for the application to next-generation drug delivery systems. The size and assembly of the AuNPs are found to be easily controlled by changing the plasma parameters and DNA concentration in the liquid. On the other hand, the mono-dispersed, small-sized, and interval-controlled AuNPs are synthesized by using the carbon nanotubes (CNTs) as a template, where the CNTs are functionalized by the ion and radical irradiation in non-equilibrium plasmas. These new materials are now widely applied to the solar cell, optical devices, and so on. Second, highly-ordered periodic structures of the AuNPs are formed by transcribing the periodic plasma structure to the surface of the liquid, where the spatially selective synthesis of the AuNPs is realized. This phenomenon is well explained by the reduction and oxidation effects of the radicals which are generated by the non-equilibrium plasma irradiation to the liquid and resultant dissociation of the liquid. In addition, it is attempted to form nano- or micro-scale periodic structures of the AuNPs based on the self-organizing behavior of turbulent plasmas generated by the nonlinear development of plasma fluctuations at the gas-liquid interface.

  14. Control systems under attack?

    CERN Document Server

    Lüders, Stefan

    2005-01-01

    The enormous growth of the Internet during the last decade offers new means to share and distribute both information and data. In Industry, this results in a rapprochement of the production facilities, i.e. their Process Control and Automation Systems, and the data warehouses. At CERN, the Internet opens the possibility to monitor and even control (parts of) the LHC and its four experiments remotely from anywhere in the world. However, the adoption of standard IT technologies to Distributed Process Control and Automation Systems exposes inherent vulnerabilities to the world. The Teststand On Control System Security at CERN (TOCSSiC) is dedicated to explore the vulnerabilities of arbitrary Commercial-Of-The-Shelf hardware devices connected to standard Ethernet. As such, TOCSSiC should discover their vulnerabilities, point out areas of lack of security, and address areas of improvement which can then be confidentially communicated to manufacturers. This paper points out risks of accessing the Control and Automa...

  15. Control and Information Systems

    Directory of Open Access Journals (Sweden)

    Jiri Zahradnik

    2003-01-01

    Full Text Available The article deals with main tends of scientific research activities of Department of Control and Information Systems at the Faculty of Electrical Engineering of University of Zilina and its perspectives in this area.

  16. Tautological control systems

    CERN Document Server

    Lewis, Andrew D

    2014-01-01

    This brief presents a description of a new modelling framework for nonlinear/geometric control theory. The framework is intended to be—and shown to be—feedback-invariant. As such, Tautological Control Systems provides a platform for understanding fundamental structural problems in geometric control theory. Part of the novelty of the text stems from the variety of regularity classes, e.g., Lipschitz, finitely differentiable, smooth, real analytic, with which it deals in a comprehensive and unified manner. The treatment of the important real analytic class especially reflects recent work on real analytic topologies by the author. Applied mathematicians interested in nonlinear and geometric control theory will find this brief of interest as a starting point for work in which feedback invariance is important. Graduate students working in control theory may also find Tautological Control Systems to be a stimulating starting point for their research.

  17. Reset Control Systems

    CERN Document Server

    Baños, Alfonso

    2012-01-01

    Reset Control Systems addresses the analysis for reset control treating both its basic form which requires only that the state of the controller be reinitialized to zero (the reset action) each time the tracking error crosses zero (the reset condition), and some useful variations of the reset action (partial reset with fixed or variable reset percentage) and of the reset condition (fixed or variable reset band and anticipative reset). The issues regarding reset control – concepts and motivation; analysis tools; and the application of design methodologies to real-world examples – are given comprehensive coverage. The text opens with an historical perspective which moves from the seminal work of the Clegg integrator and Horowitz FORE to more recent approaches based on impulsive/hybrid control systems and explains the motivation for reset compensation. Preliminary material dealing with notation, basic definitions and results, and with the definition of the control problem under study is also included. The fo...

  18. Internal control system

    OpenAIRE

    Pavésková, Ivana

    2012-01-01

    Dissertation focuse on the internal control system in the enterprises, aims to map the control system by focusing on the purchasing department. I focused on the purchasing process, because with an increasing trends of outsourcing services and the increasing interconnectedness of enterprises increases the risk of fraud currently in the purchasing process. To the research was selected the sample of companies from the banking and non-banking environment, to which were sent a questionnaire focusi...

  19. 轨姿控液体火箭发动机水击仿真模拟%Simulation of water hammer in liquid rocket engine of orbit and attitude control system

    Institute of Scientific and Technical Information of China (English)

    张峥岳; 康乃全

    2012-01-01

    Taking the liquid rocket engine of orbit and attitude control system as the study object, an emulator was established with AMESim according to the modular modeling idea. The simulation computation of water hammer pressure in the pipeline while the engine system was working was per- formed. The results show that the running of orbit control engine is a major factor creating high water hammer. The compared result of theoretical calculation and test data indicate that the simulation mod- els can give reasonable descriptions for generative process of water hammer. The measure to reduce the amount of water hammer is introduced.%以轨姿控液体火箭发动机为研究对象,根据模块化思想,利用AMESim建立了仿真平台,仿真计算了发动机系统工作中管路的水击压力。结果表明:轨控发动机的工作是引起大水击的主要因素。通过与理论计算和试验数据的对比表明,仿真模型较好地描述了管路水击的生成过程。介绍了减小系统水击量的措施。

  20. Integrated system for temperature-controlled fast protein liquid chromatography comprising improved copolymer modified beaded agarose adsorbents and a travelling cooling zone reactor arrangement.

    Science.gov (United States)

    Müller, Tobias K H; Cao, Ping; Ewert, Stephanie; Wohlgemuth, Jonas; Liu, Haiyang; Willett, Thomas C; Theodosiou, Eirini; Thomas, Owen R T; Franzreb, Matthias

    2013-04-12

    An integrated approach to temperature-controlled chromatography, involving copolymer modified agarose adsorbents and a novel travelling cooling zone reactor (TCZR) arrangement, is described. Sepharose CL6B was transformed into a thermoresponsive cation exchange adsorbent (thermoCEX) in four synthetic steps: (i) epichlorohydrin activation; (ii) amine capping; (iii) 4,4'-azobis(4-cyanovaleric acid) immobilization; and 'graft from' polymerization of poly(N-isopropylacrylamide-co-N-tert-butylacrylamide-co-acrylic acid-co-N,N'-methylenebisacrylamide). FT-IR, (1)H NMR, gravimetry and chemical assays allowed precise determination of the adsorbent's copolymer composition and loading, and identified the initial epoxy activation step as a critical determinant of 'on-support' copolymer loading, and in turn, protein binding performance. In batch binding studies with lactoferrin, thermoCEX's binding affinity and maximum adsorption capacity rose smoothly with temperature increase from 20 to 50 °C. In temperature shifting chromatography experiments employing thermoCEX in thermally jacketed columns, 44-51% of the lactoferrin adsorbed at 42 °C could be desorbed under binding conditions by cooling the column to 22 °C, but the elution peaks exhibited strong tailing. To more fully exploit the potential of thermoresponsive chromatography adsorbents, a new column arrangement, the TCZR, was developed. In TCZR chromatography, a narrow discrete cooling zone (special assembly of copper blocks and Peltier elements) is moved along a bespoke fixed-bed separation columnfilled with stationary phase. In tests with thermoCEX, it was possible to recover 65% of the lactoferrin bound at 35 °C using 8 successive movements of the cooling zone at a velocity of 0.1mm/s; over half of the recovered protein was eluted in the first peak in more concentrated form than in the feed. Intra-particle diffusion of desorbed protein out of the support pores, and the ratio between the velocities of the cooling

  1. Nonlinear Control Systems

    Science.gov (United States)

    2007-03-01

    IEEE Transactions on Automatic Control , AC- 48, pp. 1712-1723, (2003). [14] C.I. Byrnes, A. Isidori...Nonlinear internal models for output regulation,” IEEE Transactions on Automatic Control , AC-49, pp. 2244-2247, (2004). [15] C.I. Byrnes, F. Celani, A...approach,” IEEE Transactions on Automatic Control , 48 (Dec. 2003), 2172–2190. 2. C. I. Byrnes, “Differential Forms and Dynamical Systems,” to appear

  2. [Development of a novel liquid injection system].

    Science.gov (United States)

    Chen, Kai; Lv, Yong-Gui

    2009-11-01

    A liquid jet injector employs compressed gas or spring to produce a high-velocity stream to deliver liquid drug into human body through skin. There are many clinical jet injection products available, none of which is domestic. A new liquid jet injector is designed based on a comprehensive analysis of the current products. The injector consists of an ejector, trigger and a re-positioning mechanism. The jets characteristics of sample injector are tested, and the results show that the maximum exit pressure is above 15 MPa, a threshold value for penetrating into the skin.

  3. Coolant and ambient temperature control for chillerless liquid cooled data centers

    Energy Technology Data Exchange (ETDEWEB)

    Chainer, Timothy J.; David, Milnes P.; Iyengar, Madhusudan K.; Parida, Pritish R.; Simons, Robert E.

    2017-08-29

    Cooling control methods and systems include measuring a temperature of air provided to one or more nodes by an air-to-liquid heat exchanger; measuring a temperature of at least one component of the one or more nodes and finding a maximum component temperature across all such nodes; comparing the maximum component temperature to a first and second component threshold and comparing the air temperature to a first and second air threshold; and controlling a proportion of coolant flow and a coolant flow rate to the air-to-liquid heat exchanger and the one or more nodes based on the comparisons.

  4. Thermoreversible (Ionic-Liquid-Based) Aqueous Biphasic Systems.

    Science.gov (United States)

    Passos, Helena; Luís, Andreia; Coutinho, João A P; Freire, Mara G

    2016-02-04

    The ability to induce reversible phase transitions between homogeneous solutions and biphasic liquid-liquid systems, at pre-defined and suitable operating temperatures, is of crucial relevance in the design of separation processes. Ionic-liquid-based aqueous biphasic systems (IL-based ABS) have demonstrated superior performance as alternative extraction platforms, and their thermoreversible behaviour is here disclosed by the use of protic ILs. The applicability of the temperature-induced phase switching is further demonstrated with the complete extraction of two value-added proteins, achieved in a single-step. It is shown that these temperature-induced mono(bi)phasic systems are significantly more versatile than classical liquid-liquid systems which are constrained by their critical temperatures. IL-based ABS allow to work in a wide range of temperatures and compositions which can be tailored to fit the requirements of a given separation process.

  5. FABRIC QUALITY CONTROL SYSTEMS

    Directory of Open Access Journals (Sweden)

    Özlem KISAOĞLU

    2006-02-01

    Full Text Available Woven fabric quality depends on yarn properties at first, then weaving preparation and weaving processes. Defect control of grey and finished fabric is done manually on the lighted tables or automatically. Fabrics can be controlled by the help of the image analysis method. In image system the image of fabrics can be digitized by video camera and after storing controlled by the various processing. Recently neural networks, fuzzy logic, best wavelet packet model on automatic fabric inspection are developed. In this study the advantages and disadvantages of manual and automatic, on-line fabric inspection systems are given comparatively.

  6. Control of density fluctuations in atomistic-continuum simulations of dense liquids

    DEFF Research Database (Denmark)

    Kotsalis, E.M.; Walther, Jens Honore; Koumoutsakos, P.

    2007-01-01

    We present a control algorithm to eliminate spurious density fluctuations associated with the coupling of atomistic and continuum descriptions for dense liquids. A Schwartz domain decomposition algorithm is employed to couple molecular dynamics for the simulation of the atomistic system with a co...

  7. Storage, retrieval, and inventory control of donor red cells in liquid nitrogen.

    Science.gov (United States)

    Mitchell, R; Muir, W

    1972-06-01

    A system of identification and inventory control of donations and aliquots of human blood stored in liquid nitrogen is described. It is simple and easy to operate. Up to five adequate samples can be obtained from each donation at discrete intervals without the need to recover the main donation or, as is so often the case, the only single aliquot available.

  8. Study on the Holdup and Mass Transfer Performances for Gas-Liquid-Liquid System in a Screen Plate Column

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The gas and dispersed phase holdups and mass transfer coefficients of liquid-iquid were determined for gas-liquid-liquid three phase system in a screen plate column. The flow pattern of gas-liquid-liquid three phase system was studied under different gas velocities. The shape factors showed the geometric properties of screen plates and the corrected drop characteristic velocities were introduced. The phase holdup in two phases was correlated. The research results indicated that mass transfer coefficient for liquid-liquid system in a column with screen plates and gas agitation was found to increase apparently.

  9. ACCESS Pointing Control System

    Science.gov (United States)

    Brugarolas, Paul; Alexander, James; Trauger, John; Moody, Dwight; Egerman, Robert; Vallone, Phillip; Elias, Jason; Hejal, Reem; Camelo, Vanessa; Bronowicki, Allen; O'Connor, David; Partrick, Richard; Orzechowski, Pawel; Spitter, Connie; Lillie, Chuck

    2010-01-01

    ACCESS (Actively-Corrected Coronograph for Exoplanet System Studies) was one of four medium-class exoplanet concepts selected for the NASA Astrophysics Strategic Mission Concept Study (ASMCS) program in 2008/2009. The ACCESS study evaluated four major coronograph concepts under a common space observatory. This paper describes the high precision pointing control system (PCS) baselined for this observatory.

  10. Computer controlled antenna system

    Science.gov (United States)

    Raumann, N. A.

    1972-01-01

    The application of small computers using digital techniques for operating the servo and control system of large antennas is discussed. The advantages of the system are described. The techniques were evaluated with a forty foot antenna and the Sigma V computer. Programs have been completed which drive the antenna directly without the need for a servo amplifier, antenna position programmer or a scan generator.

  11. Fault Tolerant Control Systems

    DEFF Research Database (Denmark)

    Bøgh, S. A.

    was to avoid a total close-down in case of the most likely faults. The second was a fault tolerant attitude control system for a micro satellite where the operation of the system is mission critical. The purpose was to avoid hazardous effects from faults and maintain operation if possible. A method...

  12. The design of liquid drip speed monitoring device system based on MCU

    Science.gov (United States)

    Zheng, Shiyong; Li, Zhao; Li, Biqing

    2017-08-01

    This page proposed an intelligent transfusion control and monitoring system which designed by using AT89S52 micro controller as the core, using the keyboard and photoelectric sensor as the input module, digital tube and motor as the output module. The keyboard is independent and photoelectric sensor can offer reliable detection for liquid drop speed and the transfusion bottle page. When the liquid amount is less than the warning value, the system sounded the alarm, you can remove the alert by hand movement. With the advantages of speed controllable and input pulse power can be maintained of the motor, the system can control the bottle through the upper and lower slow-moving liquid drip to control the speed of intelligent purpose.

  13. Pneumatically Modulated Liquid Delivery System for Nebulizers

    Science.gov (United States)

    2011-12-02

    spectrometry (OES). Nebulizers generate a fine aerosol, or mist, of liquid droplets that are subsequently vaporized. The aerosol is generated by...Elemental Scientific, Omaha, NE USA) at 30 μL min-1 liquid flow and 1000 mL min-1 gas flow. The small droplets of the aerosol are clearly visible. Gas...PMLDS can easily be extended to microfluidic applications and nanoliter per minute to milliliter per minute flow rate ranges. The PMLDS is a flexible

  14. Free-surface molecular command systems for photoalignment of liquid crystalline materials.

    Science.gov (United States)

    Fukuhara, Kei; Nagano, Shusaku; Hara, Mitsuo; Seki, Takahiro

    2014-01-01

    The orientation of liquid crystal molecules is very sensitive towards contacting surfaces, and this phenomenon is critical during the fabrication of liquid crystal display panels, as well as optical and memory devices. To date, research has focused on designing and modifying solid surfaces. Here we report an approach to control the orientation of liquid crystals from the free (air) surface side: a skin layer at the free surface was prepared using a non-photoresponsive liquid crystalline polymer film by surface segregation or inkjet printing an azobenzene-containing liquid crystalline block copolymer. Both planar-planar and homoeotropic-planar mode patterns were readily generated. This strategy is applicable to various substrate systems, including inorganic substrates and flexible polymer films. These versatile processes require no modification of the substrate surface and are therefore expected to provide new opportunities for the fabrication of optical and mechanical devices based on liquid crystal alignment.

  15. Experimental Study on Liquid-Liquid Equilibria of Alcohol-Ester-Water-CaCl2 System

    Institute of Scientific and Technical Information of China (English)

    Fu Jiquan; Fu Die

    2014-01-01

    The binary liquid-liquid equilibrium (LLE) data for salt-containing systems of 1-butanol+water+CaCl2, n-butyl acetate+water+CaCl2 and ethyl acetate+acetic acid+water+CaCl2 were determined and the salt effect was analyzed. The results showed that an obvious salt effect could be identified for the systems of 1-butanol+water+CaCl2 and ethyl acetate+acetic acid+water.

  16. Liquid-liquid distribution of aromatic α-amino acids in multicomponent systems

    Science.gov (United States)

    Korenman, Ya. I.; Mokshina, N. Ya.; Pakhomova, O. A.

    2010-02-01

    Distribution coefficients and recovery factors of phenylalanine, tyrosine, and tryptophan are measured in extraction systems with butanol, pentanol, acetone, and ethyl acetate, their binary and ternary mixtures, and water-soluble polymers. Extraction conditions—extractant composition, salting-out agents, and pH—are optimized. Efficient systems providing maximum quantitative characteristics of the process of liquid-liquid distribution of aromatic α-amino acids are proposed.

  17. CNEOST Control Software System

    Science.gov (United States)

    Wang, X.; Zhao, H. B.; Xia, Y.; Lu, H.; Li, B.

    2015-03-01

    In 2013, CNEOST (China Near Earth Object Survey Telescope) adapted its hardware system for the new CCD camera. Based on the new system architecture, the control software is re-designed and implemented. The software system adopts the message passing mechanism via WebSocket protocol, and improves its flexibility, expansibility, and scalability. The user interface with responsive web design realizes the remote operating under both desktop and mobile devices. The stable operating of software system has greatly enhanced the operation efficiency while reducing the complexity, and has also made a successful attempt for the future system design of telescope and telescope cloud.

  18. Alginate fibres containing discrete liquid filled vacuoles for controlled delivery of healing agents in fibre reinforced composites

    NARCIS (Netherlands)

    Mookhoek, S.D.; Fischer, H.R.; Zwaag, S. van der

    2012-01-01

    The work addressed involves the preparation and application of a compartmented polymer fibre, containing multiple separated domains with liquid agent for controlled release. The created fibre is a design for improvement to the existing liquid encapsulated self-healing systems such as fibre reinforce

  19. The ISOLDE control system

    Science.gov (United States)

    Deloose, I.; Pace, A.

    1994-12-01

    The two CERN isotope separators named ISOLDE have been running on the new Personal Computer (PC) based control system since April 1992. The new architecture that makes heavy use of the commercial software and hardware of the PC market has been implemented on the 1700 geographically distributed control channels of the two separators and their experimental area. Eleven MSDOS Intel-based PCs with approximately 80 acquisition and control boards are used to access the equipment and are controlled from three PCs running Microsoft Windows used as consoles through a Novell Local Area Network. This paper describes the interesting solutions found and discusses the reduced programming workload and costs that have been obtained.

  20. Controllability of delay systems with restrained controls

    Science.gov (United States)

    Chukwu, E. N.

    1979-01-01

    Using a geometric growth condition, both the function space and Euclidean controllability of a nonlinear delay system which has a compact and convex control set are characterized. This extends analogous results for ordinary differential systems, and it yields conditions under which perturbed nonlinear delay controllable systems are controllable.

  1. Recommended Liquid-Liquid Equilibrium Data. Hydrocarbons with Seawater Systems

    Science.gov (United States)

    Góral, Marian; Gierycz, Paweł; Oracz, Paweł; Shaw, David G.

    2011-12-01

    The solubilities of C5-C26 hydrocarbons in seawater, reviewed previously, were re-evaluated using a predictive model based on the Sechenov equation. It was found that, within the scope of investigated data, the Sechenov constant is proportional to a hydrocarbon-specific parameter representing the size of the cavity in water needed to accommodate the dissolved molecule of the hydrocarbon. The proportionality coefficient has one value for n-alkanes, cycloalkanes, and alkylbenzenes, whereas for higher aromatics (including those with fused rings), a second value of the coefficient is indicated. The proposed model provides a framework for comparison of the data for various systems and helps in the recognition of systematic error. Evaluation of experimental solubility data and analysis of error propagation is given.

  2. A nanosecond pulsed laser heating system for studying liquid and supercooled liquid films in ultrahigh vacuum

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Yuntao [Physical Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99352, USA; Dibble, Collin J. [Physical Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99352, USA; Petrik, Nikolay G. [Physical Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99352, USA; Smith, R. Scott [Physical Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99352, USA; Joly, Alan G. [Physical Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99352, USA; Tonkyn, Russell G. [Physical Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99352, USA; Kay, Bruce D. [Physical Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99352, USA; Kimmel, Greg A. [Physical Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99352, USA

    2016-04-26

    A pulsed laser heating system has been developed that enables investigations of the dynamics and kinetics of nanoscale liquid films and liquid/solid interfaces on the nanosecond timescale in ultrahigh vacuum (UHV). Details of the design, implementation and characterization of a nanosecond pulsed laser system for transiently heating nanoscale films are described. Nanosecond pulses from a Nd:YAG laser are used to rapidly heat thin films of adsorbed water or other volatile materials on a clean, well-characterized Pt(111) crystal in UHV. Heating rates of ~1010 K/s for temperature increases of ~100 – 200 K are obtained. Subsequent rapid cooling (~5 × 109 K/s) quenches the film, permitting in-situ, post-mortem analysis using a variety of surface science techniques. Lateral variations in the laser pulse energy are ~ ± 3% leading to a temperature uncertainty of ~ ± 5 K for a temperature jump of 200 K. Initial experiments with the apparatus demonstrate that crystalline ice films initially held at 90 K can be rapidly transformed into liquid water films with T > 273 K. No discernable recrystallization occurs during the rapid cooling back to cryogenic temperatures. In contrast, amorphous solid water films heated below the melting point rapidly crystallize. The nanosecond pulsed laser heating system can prepare nanoscale liquid and supercooled liquid films that persist for nanoseconds per heat pulse in an UHV environment, enabling experimental studies of a wide range of phenomena in liquids and at liquid/solid interfaces.

  3. Water-saving liquid-gas conditioning system

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Christopher; Zhuang, Ye

    2014-01-14

    A method for treating a process gas with a liquid comprises contacting a process gas with a hygroscopic working fluid in order to remove a constituent from the process gas. A system for treating a process gas with a liquid comprises a hygroscopic working fluid comprising a component adapted to absorb or react with a constituent of a process gas, and a liquid-gas contactor for contacting the working fluid and the process gas, wherein the constituent is removed from the process gas within the liquid-gas contactor.

  4. Water-saving liquid-gas conditioning system

    Science.gov (United States)

    Martin, Christopher; Zhuang, Ye

    2014-01-14

    A method for treating a process gas with a liquid comprises contacting a process gas with a hygroscopic working fluid in order to remove a constituent from the process gas. A system for treating a process gas with a liquid comprises a hygroscopic working fluid comprising a component adapted to absorb or react with a constituent of a process gas, and a liquid-gas contactor for contacting the working fluid and the process gas, wherein the constituent is removed from the process gas within the liquid-gas contactor.

  5. Thermohydraulic safety issues for liquid metal cooled systems

    Energy Technology Data Exchange (ETDEWEB)

    Gerbeth, Gunter; Stefani, Frank [Helmholtz-Zentrum Dresden-Rossendorf (HZDR) e.V., Dresden (Germany). Inst. of Fluid Dynamics; Eckert, Sven

    2016-05-15

    In this paper recent developments of various techniques for single-phase and two-phase flow measurements with relevance to liquid metal cooled systems will be presented. Further, the status of the DRESDYN platform for large-scale experiments with liquid sodium is sketched.

  6. Controlled electrodeposition of Au monolayer film on ionic liquid

    Science.gov (United States)

    Ma, Qiang; Pang, Liuqing; Li, Man; Zhang, Yunxia; Ren, Xianpei; Liu, Shengzhong Frank

    2016-05-01

    Gold (Au) nanoparticles have been attractive for centuries for their vibrant appearance enhanced by their interaction with sunlight. Nowadays, there have been tremendous research efforts to develop them for high-tech applications including therapeutic agents, sensors, organic photovoltaics, medical applications, electronics and catalysis. However, there remains to be a challenge to fabricate a monolayer Au coating with complete coverage in controlled fashion. Here we present a facile method to deposit a uniform Au monolayer (ML) film on the [BMIM][PF6] ionic liquid substrate using an electrochemical deposition process. It demonstrates that it is feasible to prepare a solid phase coating on the liquid-based substrate. Moreover, the thickness of the monolayer coating can be controlled to a layer-by-layer accuracy.

  7. Reactor models for a series of continuous stirred tank reactors with a gas-liquid-solid leaching system: Part II. Gas-transfer control

    Science.gov (United States)

    Papangelakis, V. G.; Demopoulos, G. P.

    1992-12-01

    This article is the second in a three-article series devoted to the development of comprehensive three-phase steady-state reactor models. In this article in particular, model equations are developed for the case of a leaching reactor operating under pure gas-transfer control. That is, the transfer of a gaseous reactant at the g-1 interface is considered to be the controlling step of the process rather than the particle dissolution reaction itself. For the derivation of the appropriate model equations, the gas-transfer capacity of the reactor is coupled with the particle dissolution kinetics. Two model versions are developed. In model version 1, the dissolved gas is assumed to be distributed equally among all particles. On the basis of this assumption, a gastransfer control-shrinking core model (GTC-SCM) equation is formulated which, along with the segregated flow model, helps to calculate the conversion of the solid phase. The size distribution of the particles at the exit of the reactor is computed via a mass-particle size density (PSD) function derived with the use of the population balance model (PBM). In model version 2, the dissolved gas is assumed to be distributed among particles in proportion to their surface area. Using the PBM, equations are developed suitable for the calculation of the total specific surface area of the reacting solids and their conversion. Single as well as multiple parallel leaching reactions are considered in developing the two model versions.

  8. Simulation of Liquid Injection Thrust Vector Control for Mars Ascent Vehicle

    Science.gov (United States)

    Gudenkauf, Jared

    2017-01-01

    The Jet Propulsion Laboratory is currently in the initial design phase for a potential Mars Ascent Vehicle; which will be landed on Mars, stay on the surface for period of time, collect samples from the Mars 2020 rover, and then lift these samples into orbit around Mars. The engineers at JPL have down selected to a hybrid wax-based fuel rocket using a liquid oxidizer based on nitrogen tetroxide, or a Mixed Oxide of Nitrogen. To lower the gross lift-off mass of the vehicle the thrust vector control system will use liquid injection of the oxidizer to deflect the thrust of the main nozzle instead of using a gimbaled nozzle. The disadvantage of going with the liquid injection system is the low technology readiness level with a hybrid rocket. Presented in this paper is an effort to simulate the Mars Ascent Vehicle hybrid rocket nozzle and liquid injection thrust vector control system using the computational fluid dynamic flow solver Loci/Chem. This effort also includes determining the sensitivity of the thrust vector control system to a number of different design variables for the injection ports; including axial location, number of adjacent ports, injection angle, and distance between the ports.

  9. Liquid–liquid equilibrium in the lithium–lanthanum system

    Energy Technology Data Exchange (ETDEWEB)

    Khairulin, Rashid A., E-mail: kra@itp.nsc.ru [Institute of Thermophysics, Siberian Branch of the Russian Academy of Sciences, Lavrentyev Avenue 1, 630090 Novosibirsk (Russian Federation); Belozerova, Anastasiya A. [Institute of Metallurgy, Ural Division of the Russian Academy of Sciences, Amundsen Street 101, 620016 Ekaterinburg (Russian Federation); Abdullaev, Rasul N. [Novosibirsk State University, Pirogov Street 2, 630090 Novosibirsk (Russian Federation); Stankus, Sergei V. [Institute of Thermophysics, Siberian Branch of the Russian Academy of Sciences, Lavrentyev Avenue 1, 630090 Novosibirsk (Russian Federation)

    2016-08-20

    Highlights: Liquid–liquid equilibria in the Li–La system are studied experimentally. The study is conducted by a gamma-ray attenuation technique. The phase diagram of the Li–La system is refined. - Abstract: The boundaries of the liquid–liquid immiscibility region on the phase diagram of the Li–La system have been determined by the gamma-ray attenuation technique. At the monotectic temperature (1118 K), the miscibility gap ranges from 0.25 to 92.9 at.% La. As the temperature increases, the solubility of the liquid metals in each other rises slightly.

  10. Application of the penetration theory for gas - Liquid mass transfer without liquid bulk : Differences with system with a bulk

    NARCIS (Netherlands)

    van Elk, E. P.; Knaap, M. C.; Versteeg, G. F.

    2007-01-01

    Frequently applied micro models for gas-liquid mass transfer all assume the presence of a liquid bulk. However, some systems are characterized by the absence of a liquid bulk, a very thin layer of liquid flows over a solid surface. An example of such a process is absorption in a column equipped with

  11. Controllability of nonlinear systems.

    Science.gov (United States)

    Sussmann, H. J.; Jurdjevic, V.

    1972-01-01

    Discussion of the controllability of nonlinear systems described by the equation dx/dt - F(x,u). Concepts formulated by Chow (1939) and Lobry (1970) are applied to establish criteria for F and its derivatives to obtain qualitative information on sets which can be obtained from x which denotes a variable of state in an arbitrary, real, analytical manifold. It is shown that controllability implies strong accessibility for a large class of manifolds including Euclidean spaces.-

  12. Optical controlled keyboard system

    Science.gov (United States)

    Budzyński, Łukasz; Długosz, Dariusz; Niewiarowski, Bartosz; Zajkowski, Maciej

    2011-06-01

    Control systems of our computers are common devices, based on the manipulation of keys or a moving ball. Completely healthy people have no problems with the operation of such devices. Human disability makes everyday activities become a challenge and create trouble. When a man can not move his hands, the work becomes difficult or often impossible. Controlled optical keyboard is a modern device that allows to bypass the limitations of disability limbs. The use of wireless optical transmission allows to control computer using a laser beam, which cooperates with the photodetectors. The article presents the construction and operation of non-contact optical keyboard for people with disabilities.

  13. Modern tandem control systems

    Science.gov (United States)

    Lutz, J. R.; Marsaudon, J. C.

    1993-04-01

    Nowadays, tandem electrostatic accelerators can benefit greatly from the growing possibilities provided by modern control facilities. Controlling an electrostatic accelerator first requires the solution of technological problems raised by the necessity of fitting inside the tank equipment which is highly stressed by the physical environment. Then, these controls can take advantage of new techniques which appear on the market. Present computer technology provides cheap powerful workstations for efficient operator interfacing, and new modular and distributed control concepts have been developed for general use in experimental physics, in data acquisition and in control systems. The general trend towards standardization is now accepted for both hardware and software and this brings benefits to the designer and the user.

  14. A perfluorochemical loss/restoration (L/R) system for tidal liquid ventilation.

    Science.gov (United States)

    Libros, R; Philips, C M; Wolfson, M R; Shaffer, T H

    2000-01-01

    Tidal liquid ventilation is the transport of dissolved respiratory gases via volume exchange of perfluorochemical (PFC) liquid to and from the PFC-filled lung. All gas-liquid surface tension is eliminated, increasing compliance and providing lung protection due to lower inflation pressures. Tidal liquid ventilation is achieved by cycling fluid from a reservoir to and from the lung by a ventilator. Current approaches are microprocessor-based with feedback control. During inspiration, warmed oxygenated PFC liquid is pumped from a fluid reservoir/gas exchanger into the lung. PFC fluid is conserved by condensing (60-80% efficiency) vapor in the expired gas. A feedback-control system was developed to automatically replace PFC lost due to condenser inefficiency. This loss/restoration (L/R) system consists of a PFC-vapor thermal detector (+/- 2.5%), pneumatics, amplifiers, a gas flow detector (+/- 1%), a PFC pump (+/- 5%), and a controller. Gravimetric studies of perflubron loss from a flask due to evaporation were compared with experimental L/R results and found to be within +/- 1.4%. In addition, when L/R studies were conducted with a previously reported liquid ventilation system over a four-hour period, the L/R system maintained system perflubron volume to within +/- 1% of prime volume and 11.5% of replacement volume, and the difference between experimental PFC loss and that of the L/R system was 1.8 mL/hr. These studies suggest that the PFC L/R system may have significant economic (appropriate dosing for PFC loss) as well as physiologic (maintenance of PFC inventory in the lungs and liquid ventilator) impact on liquid ventilation procedures.

  15. Control of complex systems

    CERN Document Server

    Albertos, Pedro; Blanke, Mogens; Isidori, Alberto; Schaufelberger, Walter; Sanz, Ricardo

    2001-01-01

    The world of artificial systems is reaching complexity levels that es­ cape human understanding. Surface traffic, electricity distribution, air­ planes, mobile communications, etc. , are examples that demonstrate that we are running into problems that are beyond classical scientific or engi­ neering knowledge. There is an ongoing world-wide effort to understand these systems and develop models that can capture its behavior. The reason for this work is clear, if our lack of understanding deepens, we will lose our capability to control these systems and make they behave as we want. Researchers from many different fields are trying to understand and develop theories for complex man-made systems. This book presents re­ search from the perspective of control and systems theory. The book has grown out of activities in the research program Control of Complex Systems (COSY). The program has been sponsored by the Eu­ ropean Science Foundation (ESF) which for 25 years has been one of the leading players in stimula...

  16. Efficient energy storage in liquid desiccant cooling systems

    Energy Technology Data Exchange (ETDEWEB)

    Hublitz, Astrid

    2008-07-18

    Liquid Desiccant Cooling Systems (LDCS) are open loop sorption systems for air conditioning that use a liquid desiccant such as a concentrated salt solution to dehumidify the outside air and cool it by evaporative cooling. Thermochemical energy storage in the concentrated liquid desiccant can bridge power mismatches between demand and supply. Low-flow LDCS provide high energy storage capacities but are not a state-of-the-art technology yet. The key challenge remains the uniform distribution of the liquid desiccant on the heat and mass transfer surfaces. The present research analyzes the factors of influence on the energy storage capacity by simulation of the heat and mass transfer processes and specifies performance goals for the distribution of the process media. Consequently, a distribution device for the liquid desiccant is developed that reliably meets the performance goals. (orig.)

  17. Automated methanol dosage using liquid flow controllers; Automatisierte Methanolregelung mit Liquid Flow Controllern

    Energy Technology Data Exchange (ETDEWEB)

    Sattler, Thomas [Buerkert Fluid Control Systems, Ingelfingen (Germany)

    2010-12-15

    Transmission gearwheels are frequently exposed to extreme loads. Generally, in order to counteract premature wear, gearwheels made from steel are surface-hardened. This is carried out primarily by gas carburizing and subsequent quenching (case hardening). These processes of gas carburizing increase the carbon content in the boundary area of the workpiece and change the boundary structure of the steel. In the foundation Institut fuer Werkstofftechnik (IWT) (Institute for Materials Engineering) in Bremen, they are engaged intensively with the various processes of heat treatment for the hardening of steel. As an alternative to gas carburizing using endogas, the Nitrogen-Methanol Process, in which liquid methanol is directly introduced into the furnace, plays an important role and is gaining in importance. At the IWT, Liquid Flow Controllers (LFC) provide regulated and completely documented processes. (orig.)

  18. Supervisory Control of Networked Control Systems

    Science.gov (United States)

    2006-01-15

    REPORT: January 15, 2006 Problem Statement: A networked control system is a control system whose feedback path is realized over a computer...theoretical bounds derived in [Ling03a]. 6. The feedback information in a networked control system is quantized due to the digital nature of

  19. Controllability of Complex Systems

    Science.gov (United States)

    Slotine, Jean-Jacques

    2013-03-01

    We review recent work on controllability of complex systems. We also discuss the interplay of our results with questions of synchronization, and point out key directions of future research. Work done in collaboration with Yang-Yu Liu, Center for Complex Network Research and Departments of Physics, Computer Science and Biology, Northeastern University and Center for Cancer Systems Biology, Dana-Farber Cancer Institute; and Albert-László Barabási, Center for Complex Network Research and Departments of Physics, Computer Science and Biology, Northeastern University; Center for Cancer Systems Biology, Dana-Farber Cancer Institute; and Department of Medicine, Brigham and Women's Hospital, Harvard Medical School.

  20. Internet Congestion Control System

    Directory of Open Access Journals (Sweden)

    Pranoto Rusmin

    2010-10-01

    Full Text Available Internet congestion occurs when resource demands exceeds the network capacity. But, it is not the only reason. Congestion can happen on some users because some others user has higher sending rate. Then some users with lower sending rate will experience congestion. This partial congestion is caused by inexactly feedback. At this moment congestion are solved by the involvement of two controlling mechanisms. These mechanisms are flow/congestion control in the TCP source and Active Queue Management (AQM in the router. AQM will provide feedback to the source a kind of indication for the occurrence of the congestion in the router, whereas the source will adapt the sending rate appropriate with the feedback. These mechanisms are not enough to solve internet congestion problem completely. Therefore, this paper will explain internet congestion causes, weakness, and congestion control technique that researchers have been developed. To describe congestion system mechanisms and responses, the system will be simulated by Matlab.

  1. Electric turbocompound control system

    Energy Technology Data Exchange (ETDEWEB)

    Algrain, Marcelo C. (Dunlap, IL)

    2007-02-13

    Turbocompound systems can be used to affect engine operation using the energy in exhaust gas that is driving the available turbocharger. A first electrical device acts as a generator in response to turbocharger rotation. A second electrical device acts as a motor to put mechanical power into the engine, typically at the crankshaft. Apparatus, systems, steps, and methods are described to control the generator and motor operations to control the amount of power being recovered. This can control engine operation closer to desirable parameters for given engine-related operating conditions compared to actual. The electrical devices can also operate in "reverse," going between motor and generator functions. This permits the electrical device associated with the crankshaft to drive the electrical device associated with the turbocharger as a motor, overcoming deficient engine operating conditions such as associated with turbocharger lag.

  2. Liquid rad waste system improvement at YGN 5 and 6

    Energy Technology Data Exchange (ETDEWEB)

    Lee, B. S.; Kang, Y. H.; Shin, Y. H. [Korea Power Engineering Company Inc. (KOPEC), Yonggin, Kyunggido(Korea, Republic of)

    1999-07-01

    The performance of the rad waste system is measured in terms of the generation of waste volumes, the release of radioactive materials to the environment and the occupational radiation exposure to workers. Based on our design and operating experience from PWR plants, various design goals for the liquid rad waste system were developed to improve system performance. As a result of feasibility studies for an improved liquid rad waste system, a design concept was developed to meet the basic design goals, which have been incorporated into the YGN 5 and 6 system. As a result, the performance of the system will be significantly improved. (author)

  3. 46 CFR 154.1300 - Liquid level gauging system: General.

    Science.gov (United States)

    2010-10-01

    ... Equipment Instrumentation § 154.1300 Liquid level gauging system: General. (a) If Table 4 lists a closed... type device, electronic or magnetic probe, or bubble tube indicator. (b) If Table 4 lists a...

  4. CANDU 6 liquid injection shutdown system waterhammer analysis using PTRAN

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Deuk Yoon; Kim, Eun Ki; Ko, Yong Sang; Park, Byung Ho; Kim, Seok Bum [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1996-06-01

    An in-core LOCA could result in flooding of the helium header in the liquid injection shutdown system. Flooding of the helium header will result in severe pressure transients (waterhammer) in the liquid injection shutdown system when the shutdown signal is initiated. To evaluate the impact of the dynamic effects of this event, a pressure transient analysis has been performed. This analysis is performed using PTRAN, which is a computer program based on the method of characteristics. The results of this analysis are used in the stress analysis of the piping and pipe supports to ensure that the liquid injection shutdown system can withstand the pressure transient loadings. This analysis report documents the results of waterhammer analysis performed for the liquid injection shutdown system for the Wolsung nuclear power plant unit 2, 3 and 4. 4 tabs., 11 figs., 15 refs. (Author).

  5. The ISOLDE control system

    Energy Technology Data Exchange (ETDEWEB)

    Deloose, I. (CERN, PS Division, CH-1211 Geneva 23 (Switzerland)); Pace, A. (CERN, PS Division, CH-1211 Geneva 23 (Switzerland))

    1994-12-15

    The two CERN isotope separators named ISOLDE have been running on the new Personal Computer (PC) based control system since April 1992. The new architecture that makes heavy use of the commercial software and hardware of the PC market has been implemented on the 1700 geographically distributed control channels of the two separators and their experimental area. Eleven MSDOS Intel-based PCs with approximately 80 acquisition and control boards are used to access the equipment and are controlled from three PCs running Microsoft Windows used as consoles through a Novell Local Area Network. This paper describes the interesting solutions found and discusses the reduced programming workload and costs that have been obtained. ((orig.))

  6. Electromagnetic control of mass transfer at liquid/liquid interfaces; Controle electromagnetique des transferts de masse aux interfaces liquide/liquide

    Energy Technology Data Exchange (ETDEWEB)

    Saadi, B

    2006-04-15

    Most metallurgical processes, such as steel refining or nuclear waste processing; the interfaces between two liquid phases are the regions of mass transfer. These transfers require the implementation of a means of stirring to accelerate the kinetics of the pollutants transfer between both phases. This thesis deals with the use of the electromagnetic forces to stir, without any material contact, the bath core and the interface in order to control or even increase the kinetic transfers. To achieve this, two complementary experimental installations were used. The first experiment allows the measurement of the Indium transfer, initially dissolved in mercury towards a covering electrolyte layer and the velocity field in mercury. The performed experiments, determine the topology of the fields flows speeds in the mercury bath, moreover the behaviour of the transfer kinetics versus the intensity of the magnetic field are established. This evolution is correlated with the dynamic behaviour of the mercury surface. The second installation allows the characterization of an element transfer (Pb, Zr or Ce) initially contained in a fluorinated salt towards an antimony matrix containing lithium. It appears that all transfers kinetics are very fast. The proposed experimental set-up is particularly efficient for Cerium transfer (limited by the interface) but does not present any action for Zirconium transfer. (author)

  7. An Overview of Liquid Fluoride Salt Heat Transport Systems

    Energy Technology Data Exchange (ETDEWEB)

    Holcomb, David Eugene [ORNL; Cetiner, Sacit M [ORNL

    2010-09-01

    , and this report also describes more recently developed technologies such as dry gas seals. This report also provides a high-level, parametric evaluation of LSHT loop performance to allow general intercomparisons between heat-transport fluid options as well as provide an overview of the properties and requirements for a representative loop. A compilation of relevant thermophysical properties of useful fluoride salts is also included for salt heat transport systems. Fluoride salts can be highly corrosive depending on the container materials selected, the salt chemistry, and the operating procedures used. The report includes an overview of the state-of-the-art in reduction-oxidation chemistry control methodologies employed to minimize corrosion issues. Salt chemistry control technology, however, remains at too low a level of understanding for widespread industrial usage. Loop operational issues such as start-up procedures and system freeze-up vulnerability are also discussed. Liquid fluoride salts are a leading candidate heat transport medium for high-temperature applications. This report provides an overview of the current status of liquid salt heat transport technology. The report includes a high-level, parametric evaluation of liquid fluoride salt heat transport loop performance to allow intercomparisons between heat-transport fluid options as well as providing an overview of the properties and requirements for a representative loop. Much of the information presented here derives from the earlier molten salt reactor program and a significant advantage of fluoride salts, as high temperature heat transport media is their consequent relative technological maturity. The report also includes a compilation of relevant thermophysical properties of useful heat transport fluoride salts. Fluoride salts are both thermally stable and with proper chemistry control can be relatively chemically inert. Fluoride salts can, however, be highly corrosive depending on the container

  8. An Overview of Liquid Fluoride Salt Heat Transport Systems

    Energy Technology Data Exchange (ETDEWEB)

    Holcomb, David Eugene [ORNL; Cetiner, Sacit M [ORNL

    2010-09-01

    , and this report also describes more recently developed technologies such as dry gas seals. This report also provides a high-level, parametric evaluation of LSHT loop performance to allow general intercomparisons between heat-transport fluid options as well as provide an overview of the properties and requirements for a representative loop. A compilation of relevant thermophysical properties of useful fluoride salts is also included for salt heat transport systems. Fluoride salts can be highly corrosive depending on the container materials selected, the salt chemistry, and the operating procedures used. The report includes an overview of the state-of-the-art in reduction-oxidation chemistry control methodologies employed to minimize corrosion issues. Salt chemistry control technology, however, remains at too low a level of understanding for widespread industrial usage. Loop operational issues such as start-up procedures and system freeze-up vulnerability are also discussed. Liquid fluoride salts are a leading candidate heat transport medium for high-temperature applications. This report provides an overview of the current status of liquid salt heat transport technology. The report includes a high-level, parametric evaluation of liquid fluoride salt heat transport loop performance to allow intercomparisons between heat-transport fluid options as well as providing an overview of the properties and requirements for a representative loop. Much of the information presented here derives from the earlier molten salt reactor program and a significant advantage of fluoride salts, as high temperature heat transport media is their consequent relative technological maturity. The report also includes a compilation of relevant thermophysical properties of useful heat transport fluoride salts. Fluoride salts are both thermally stable and with proper chemistry control can be relatively chemically inert. Fluoride salts can, however, be highly corrosive depending on the container

  9. Microprocessor control for standardized power control systems

    Science.gov (United States)

    Green, D. G.; Perry, E.

    1978-01-01

    The use of microcomputers in space-oriented power systems as a replacement for existing inflexible analog type controllers has been proposed. This study examines multiprocessor systems, various modularity concepts and presents a conceptualized power system incorporating a multiprocessor controller as well as preliminary results from a breadboard model of the proposed system.

  10. Wireless Remote Control System

    Directory of Open Access Journals (Sweden)

    Adrian Tigauan

    2012-06-01

    Full Text Available This paper presents the design of a wireless remote control system based on the ZigBee communication protocol. Gathering data from sensors or performing control tasks through wireless communication is advantageous in situations in which the use of cables is impractical. An Atmega328 microcontroller (from slave device is used for gathering data from the sensors and transmitting it to a coordinator device with the help of the XBee modules. The ZigBee standard is suitable for low-cost, low-data-rate and low-power wireless networks implementations. The XBee-PRO module, designed to meet ZigBee standards, requires minimal power for reliable data exchange between devices over a distance of up to 1600m outdoors. A key component of the ZigBee protocol is the ability to support networking and this can be used in a wireless remote control system. This system may be employed e.g. to control temperature and humidity (SHT11 sensor and light intensity (TSL230 sensor levels inside a commercial greenhouse.

  11. Dynamitron control systems

    Science.gov (United States)

    Lisanti, Thomas F.

    2005-12-01

    The Dynamitron control system utilizes the latest personal computer technology in control circuitry and components. Both the DPC-2000 and newer Millennium series of control systems make use of their modular architecture in both software and hardware to keep up with customer and engineering demands. This also allows the main structure of the software to remain constant for the user while software drivers are easily changed as hardware demands are modified and improved. The system is presented as four units; the Remote I/O (Input/Output), Local Analog and Digital I/O, Operator Interface and the Main Computer. The operator is provided with a selection of many informative screen displays. The control program handles all graphic screen displays and the updating of these screens directly; it does not communicate to a display terminal. This adds to the quick response and excellent operator feedback received while operating the accelerator. The CPU also has the ability to store and record all process variable setpoints for each product that will be treated. All process parameters are printed to a report at regular intervals during a process run for record keeping.

  12. Management control system description

    Energy Technology Data Exchange (ETDEWEB)

    Bence, P. J.

    1990-10-01

    This Management Control System (MCS) description describes the processes used to manage the cost and schedule of work performed by Westinghouse Hanford Company (Westinghouse Hanford) for the US Department of Energy, Richland Operations Office (DOE-RL), Richland, Washington. Westinghouse Hanford will maintain and use formal cost and schedule management control systems, as presented in this document, in performing work for the DOE-RL. This MCS description is a controlled document and will be modified or updated as required. This document must be approved by the DOE-RL; thereafter, any significant change will require DOE-RL concurrence. Westinghouse Hanford is the DOE-RL operations and engineering contractor at the Hanford Site. Activities associated with this contract (DE-AC06-87RL10930) include operating existing plant facilities, managing defined projects and programs, and planning future enhancements. This document is designed to comply with Section I-13 of the contract by providing a description of Westinghouse Hanford's cost and schedule control systems used in managing the above activities. 5 refs., 22 figs., 1 tab.

  13. Isothermal (liquid + liquid) equilibrium data at T = 313.15 K and isobaric (vapor + liquid + liquid) equilibrium data at 101.3 kPa for the ternary system (water + 1-butanol + p-xylene)

    OpenAIRE

    Gomis Yagües, Vicente; Font Escamilla, Alicia; Saquete Ferrándiz, María Dolores; García Cano, Jorge

    2014-01-01

    The (vapor + liquid), (liquid + liquid) and (vapor + liquid + liquid) equilibria of the ternary system (water + 1-butanol + p-xylene) have been determined. (Water + 1-butanol + p-xylene) is a type 2 heterogeneous ternary system with partially miscible (water + 1-butanol) and (water + p-xylene) pairs. By contrast, (1-butanol + p-xylene) is totally miscible under atmospheric conditions. This paper examines the (vapor + liquid) equilibrium in both heterogeneous and homogeneous regions at 101.3 k...

  14. Liquid-Liquid equilibria of the water-acetic acid-butyl acetate system

    Directory of Open Access Journals (Sweden)

    E. Ince

    2002-04-01

    Full Text Available Experimental liquid-liquid equilibria of the water-acetic acid-butyl acetate system were studied at temperatures of 298.15± 0.20, 303.15± 0.20 and 308.15± 0.20 K. Complete phase diagrams were obtained by determining solubility and tie-line data. The reliability of the experimental tie-line data was ascertained by using the Othmer and Tobias correlation. The UNIFAC group contribution method was used to predict the observed ternary liquid-liquid equilibrium (LLE data. It was found that UNIFAC group interaction parameters used for LLE did not provide a good prediction. Distribution coefficients and separation factors were evaluated for the immiscibility region.

  15. Nuclotron Control System

    Science.gov (United States)

    Volkov, V.; Gorchenko, V.; Kirichenko, A.; Kovalenko, A.; Kulikov, I.; Romanov, S.; Sveshnikov, B.; Vasilishin, B.

    1997-05-01

    The superconducting synchrotron named Nuclotron based on a miniature iron-shaped field SC-magnets was put into operation at the LHE JINR in 1993.The Nuclotron Control System (NCS) project,which is still under development,started in 1992 and has provided efficient support for the machine commissioning through all its phases.This paper presents the current status of the NCS. The control system architecture is hierarc- hical in nature and consists of two physical levels. High performance workstations,together with a general purpose server computers, are used at the top level.Workstations act as an operator consoles,while the servers provide massive disk data storage,printing utilities,a common database, program library and data exchange between Nuclotron and its experiments. The front-end level comprises as industrial com- puters equipped with I/O boards and data acquisition modules, as in- telligent CAMAC crate-controllers with embedded micro-PCs. NCS is distributed system,in which subsytems geographically separated by as much as 500 m.The total number of computers presently installed is 25. An Ethernet Local Area Network,which runs IPX/SPX and TCP/IP communi- cation protocols ,connects the console computers to the front-end le- vel and physicists workstations.

  16. Experimental analysis on adjusting performance of vapor-liquid two-phase flow controller

    Institute of Scientific and Technical Information of China (English)

    LI Hui-jun; TU Shan

    2006-01-01

    The vapor-liquid self-adjusting controller is an innovative automatic regulating valve. In order to ensure adjusted objects run safely and economically, the controller automatically adjusts the liquid flux to keep liquid level at a required level according to physical properties of vapor-liquid two-phase fluid. The adjusting mechanics, the controller' s performance and influencing factors of its stability have been analyzed in this paper. The theoretical analysis and successful applications have demonstrated this controller can keep the liquid level steady with good performance. The actual application in industry has shown that the controller can satisfactorily meet the requirement of industrial production and has wide application areas.

  17. Functions and requirements document, WESF decoupling project, low-level liquid waste system

    Energy Technology Data Exchange (ETDEWEB)

    Rasmussen, J.H., Fluor Daniel Hanford

    1997-02-27

    The Waste Encapsulation and Storage Facility (WESF) was constructed in 1974 to encapsulate and store cesium and strontium which were isolated at B Plant from underground storage tank waste. The WESF, Building 225-B, is attached physically to the west end of B Plant, Building 221-B, 200 East area. The WESF currently utilizes B Plant facilities for disposing liquid and solid waste streams. With the deactivation of B Plant, the WESF Decoupling Project will provide replacement systems allowing WESF to continue operations independently from B Plant. Four major systems have been identified to be replaced by the WESF Decoupling Project, including the following: Low Level Liquid Waste System, Solid Waste Handling System, Liquid Effluent Control System, and Deionized Water System.

  18. Liquid - liquid equilibria of the water + butyric acid + decanol ternary system

    Directory of Open Access Journals (Sweden)

    S.I. Kirbaslar

    2006-09-01

    Full Text Available Liquid-liquid equilibrium (LLE data for the water + butyric acid + decanol ternary system were determined experimentally at temperatures of 298.15, 308.15 and 318.15 K. Complete phase diagrams were obtained by determining the solubility curve and the tie lines. The reliability of the experimental tie line data was confirmed with the Othmer-Tobias correlation. The UNIFAC method was used to predict the phase equilibrium of the system using the interaction parameters for groups CH3, CH2, COOH, OH and H2O determined experimentally. Distribution coefficients and separation factors were evaluated for the immiscibility region.

  19. A nanosecond pulsed laser heating system for studying liquid and supercooled liquid films in ultrahigh vacuum.

    Science.gov (United States)

    Xu, Yuntao; Dibble, Collin J; Petrik, Nikolay G; Smith, R Scott; Joly, Alan G; Tonkyn, Russell G; Kay, Bruce D; Kimmel, Greg A

    2016-04-28

    A pulsed laser heating system has been developed that enables investigations of the dynamics and kinetics of nanoscale liquid films and liquid/solid interfaces on the nanosecond time scale in ultrahigh vacuum (UHV). Details of the design, implementation, and characterization of a nanosecond pulsed laser system for transiently heating nanoscale films are described. Nanosecond pulses from a Nd:YAG laser are used to rapidly heat thin films of adsorbed water or other volatile materials on a clean, well-characterized Pt(111) crystal in UHV. Heating rates of ∼10(10) K/s for temperature increases of ∼100-200 K are obtained. Subsequent rapid cooling (∼5 × 10(9) K/s) quenches the film, permitting in-situ, post-heating analysis using a variety of surface science techniques. Lateral variations in the laser pulse energy are ∼±2.7% leading to a temperature uncertainty of ∼±4.4 K for a temperature jump of 200 K. Initial experiments with the apparatus demonstrate that crystalline ice films initially held at 90 K can be rapidly transformed into liquid water films with T > 273 K. No discernable recrystallization occurs during the rapid cooling back to cryogenic temperatures. In contrast, amorphous solid water films heated below the melting point rapidly crystallize. The nanosecond pulsed laser heating system can prepare nanoscale liquid and supercooled liquid films that persist for nanoseconds per heat pulse in an UHV environment, enabling experimental studies of a wide range of phenomena in liquids and at liquid/solid interfaces.

  20. A nanosecond pulsed laser heating system for studying liquid and supercooled liquid films in ultrahigh vacuum

    Science.gov (United States)

    Xu, Yuntao; Dibble, Collin J.; Petrik, Nikolay G.; Smith, R. Scott; Joly, Alan G.; Tonkyn, Russell G.; Kay, Bruce D.; Kimmel, Greg A.

    2016-04-01

    A pulsed laser heating system has been developed that enables investigations of the dynamics and kinetics of nanoscale liquid films and liquid/solid interfaces on the nanosecond time scale in ultrahigh vacuum (UHV). Details of the design, implementation, and characterization of a nanosecond pulsed laser system for transiently heating nanoscale films are described. Nanosecond pulses from a Nd:YAG laser are used to rapidly heat thin films of adsorbed water or other volatile materials on a clean, well-characterized Pt(111) crystal in UHV. Heating rates of ˜1010 K/s for temperature increases of ˜100-200 K are obtained. Subsequent rapid cooling (˜5 × 109 K/s) quenches the film, permitting in-situ, post-heating analysis using a variety of surface science techniques. Lateral variations in the laser pulse energy are ˜±2.7% leading to a temperature uncertainty of ˜±4.4 K for a temperature jump of 200 K. Initial experiments with the apparatus demonstrate that crystalline ice films initially held at 90 K can be rapidly transformed into liquid water films with T > 273 K. No discernable recrystallization occurs during the rapid cooling back to cryogenic temperatures. In contrast, amorphous solid water films heated below the melting point rapidly crystallize. The nanosecond pulsed laser heating system can prepare nanoscale liquid and supercooled liquid films that persist for nanoseconds per heat pulse in an UHV environment, enabling experimental studies of a wide range of phenomena in liquids and at liquid/solid interfaces.

  1. Molecular absorption cryogenic cooler for liquid hydrogen propulsion systems

    Science.gov (United States)

    Klein, G. A.; Jones, J. A.

    1982-01-01

    A light weight, long life molecular absorption cryogenic cooler (MACC) system is described which can use low temperature waste heat to provide cooling for liquid hydrogen propellant tanks for interplanetary spacecraft. Detailed tradeoff studies were made to evaluate the refrigeration system component interactions in order to minimize the mass of the spacecraft cooler system. Based on this analysis a refrigerator system mass of 31 kg is required to provide the .48 watts of cooling required by a 2.3 meter diameter liquid hydrogen tank.

  2. Liquidity creation and risk in the international monetary system

    Directory of Open Access Journals (Sweden)

    L. DINI

    2013-12-01

    Full Text Available The article looks at how the present financial system works, signalling out its most crucial function, namely the provision of liquidity and its impact on the broad spectrum of international financial variables. Liquidity and risk are closely interrelated concepts. As Keynes and Hicks taught, a meaningful definition of liquidity cannot be given without reference to risk itself. The author provides some considerations to help shed light on the policy actions that may be required to mitigate the problems and difficulties associated with the current international monetary setting.

  3. Liquid Chromatography Applied to Space System

    Science.gov (United States)

    Poinot, Pauline; Chazalnoel, Pascale; Geffroy, Claude; Sternberg, Robert; Carbonnier, Benjamin

    Searching for signs of past or present life in our Solar System is a real challenge that stirs up the curiosity of scientists. Until now, in situ instrumentation was designed to detect and determine concentrations of a wide number of organic biomarkers. The relevant method which was and still is employed in missions dedicated to the quest of life (from Viking to ExoMars) corresponds to the pyrolysis-GC-MS. Along the missions, this approach has been significantly improved in terms of extraction efficiency and detection with the use of chemical derivative agents (e.g. MTBSTFA, DMF-DMA, TMAH…), and in terms of analysis sensitivity and resolution with the development of in situ high-resolution mass spectrometer (e.g. TOF-MS). Thanks to such an approach, organic compounds such as amino acids, sugars, tholins or polycyclic aromatic hydrocarbons (PAHs) were expected to be found. However, while there’s a consensus that the GC-MS of Viking, Huygens, MSL and MOMA space missions worked the way they had been designed to, pyrolysis is much more in debate (Glavin et al. 2001; Navarro-González et al. 2006). Indeed, (1) it is thought to remove low levels of organics, (2) water and CO2 could interfere with the detection of likely organic pyrolysis products, and (3) only low to mid-molecular weight organic molecules can be detected by this technique. As a result, researchers are now focusing on other in situ techniques which are no longer based on the volatility of the organic matter, but on the liquid phase extraction and analysis. In this line, micro-fluidic systems involving sandwich and/or competitive immunoassays (e.g. LMC, SOLID; Parro et al. 2005; Sims et al. 2012), micro-chip capillary electrophoreses (e.g. MOA; Bada et al. 2008), or nanopore-based analysis (e.g. BOLD; Schulze-Makuch et al. 2012) have been conceived for in situ analysis. Thanks to such approaches, molecular biological polymers (polysaccharides, polypeptides, polynucleotides, phospholipids, glycolipids

  4. Closed-loop adaptive optical system with a liquid mirror.

    Science.gov (United States)

    Vdovin, Gleb

    2009-02-15

    A deformable mirror based on internal reflection from an electrostatically deformable liquid-air interface is proposed and investigated. A differential equation describing the static behavior of such a mirror is analyzed and solved numerically. Stable closed-loop operation of an adaptive optical system with a liquid deformable mirror is demonstrated, including forming and the correction of low-order aberrations described by Zernike polynomials and the real-time correction of dynamically changing aberrations.

  5. Modeling of the thyme: Liquid carbon dioxide extraction system

    Directory of Open Access Journals (Sweden)

    Zeković Zoran P.

    2003-01-01

    Full Text Available The extraction of thyme (Thymus vulgaris L by liquid carbon dioxide was investigated. The obtained extracts were analyzed by HPLC and GC-MS methods, and their composition was compared with that of the essential oil obtained by steam distillation and by supercritical carbon dioxide at 100 bar and 40°C. To model extraction of the thyme - liquid carbon dioxide system, we used the Reverchon - Sesti Osseo equation, as well as our modified equation.

  6. Liquid-drop-like model for cylindrical helium systems

    Science.gov (United States)

    Szybisz, Leszek

    2000-08-01

    Free liquid 4He at T=0 K with cylindrical symmetry is studied. The ground-state energy and chemical potential are computed by using a density functional approach. A liquid-drop-like model is formulated for analyzing the behavior of these observables as a function of the size of the systems. It is shown that such a model allows to get precise information about the asymptotic values of the energy per particle and surface tension.

  7. (Liquid + liquid) equilibria of {l_brace}heptane + xylene + N-formylmorpholine{r_brace} ternary system

    Energy Technology Data Exchange (ETDEWEB)

    Chen Dongchu [College of Chemistry and Chemical Engineering, Central South University, ChangSha 410083 (China)], E-mail: dcchen@hnust.edu.cn; Ye Hongqi; Hao Wu [College of Chemistry and Chemical Engineering, Central South University, ChangSha 410083 (China)

    2007-12-15

    (Liquid + liquid) equilibrium (LLE) data for ternary system {l_brace}heptane (1) + m-xylene (2) + N-formylmorpholine (3){r_brace} have been determined experimentally at temperatures ranging from 298.15 K to 353.15 K. Complete phase diagrams were obtained by determining solubility and tie-line data. Tie-line compositions were correlated by Othmer-Tobias and Bachman methods. The universal quasichemical activity coefficient (UNIQUAC) and The non-random two liquids equation (NRTL) were used to correlate the phase equilibrium in the system using the interaction parameters determined from experimental data. It is found that UNIQUAC and NRTL used for LLE could provide a good correlation. Distribution coefficients, separation factors, and selectivity were evaluated for the immiscibility region.

  8. MIRADAS control system

    Science.gov (United States)

    Rosich Minguell, Josefina; Garzón Lopez, Francisco

    2012-09-01

    The Mid-resolution InfRAreD Astronomical Spectrograph (MIRADAS, a near-infrared multi-object echelle spectrograph operating at spectral resolution R=20,000 over the 1-2.5μm bandpass) was selected in 2010 by the Gran Telescopio Canarias (GTC) partnership as the next-generation near-infrared spectrograph for the world's largest optical/infrared telescope, and is being developed by an international consortium. The MIRADAS consortium includes the University of Florida, Universidad de Barcelona, Universidad Complutense de Madrid, Instituto de Astrofísica de Canarias, Institut de Física d'Altes Energies, Institut d'Estudis Espacials de Catalunya and Universidad Nacional Autónoma de México. This paper shows an overview of the MIRADAS control software, which follows the standards defined by the telescope to permit the integration of this software on the GTC Control System (GCS). The MIRADAS Control System is based on a distributed architecture according to a component model where every subsystem is selfcontained. The GCS is a distributed environment written in object oriented C++, which runs components in different computers, using CORBA middleware for communications. Each MIRADAS observing mode, including engineering, monitoring and calibration modes, will have its own predefined sequence, which are executed in the GCS Sequencer. These sequences will have the ability of communicating with other telescope subsystems.

  9. Centrifugal contactor with liquid mixing and flow control vanes and method of mixing liquids of different phases

    Science.gov (United States)

    Jubin, Robert T.; Randolph, John D.

    1991-01-01

    The invention is directed to a centrifugal contactor for solvent extraction systems. The centrifugal contactor is provided with an annular vertically oriented mixing chamber between the rotor housing and the rotor for mixing process liquids such as the aqueous and organic phases of the solvent extraction process used for nuclear fuel reprocessing. A set of stationary helically disposed vanes carried by the housing is in the lower region of the mixing chamber at a location below the process-liquid inlets for the purpose of urging the liquids in an upward direction toward the inlets and enhancing the mixing of the liquids and mass transfer between the liquids. The upper region of the mixing vessel above the inlets for the process liquids is also provided with a set helically disposed vanes carried by the housing for urging the process liquids in a downward direction when the liquid flow rates through the inlets are relatively high and the liquids contact the vane set in the upper region. The use of these opposing vane sets in the mixing zone maintains the liquid in the mixing zone at suitable levels.

  10. A Calibration-Free, Noncontact, Disposable Liquid Dispensing Cartridge Featuring an Online Process Control.

    Science.gov (United States)

    Bammesberger, Stefan Borja; Malki, Imad; Ernst, Andreas; Zengerle, Roland; Koltay, Peter

    2014-08-01

    We present a noncontact liquid dispenser that uses a disposable cartridge for the calibration-free dosage of diverse biochemical reagents from the nanoliter to the microliter range. The dispensing system combines the advantages of a positive displacement syringe pump (responsible for defining the aliquot's volume with high accuracy) with a highly dynamic noncontact dispenser (providing kinetic energy to detach the liquid from the tip). The disposable, noncontact dispensing cartridge system renders elaborate washing procedures of tips obsolete. A noncontact sensor monitors the dispensing process to enable an online process control. To further increase confidence and reliability for particularly critical biomedical applications, an optional closed-loop control prevents malfunctions. The dispensing performance was characterized experimentally in the range of 0.25 to 10.0 µL using liquids of different rheological properties (viscosity 1.03-16.98 mPas, surface tension 30.49-70.83 mN/m) without adjusting or calibrating the actuation parameters. The precision ranged between a coefficient of variation of 0.5% and 5.3%, and the accuracy was below ±10%. The presented technology has the potential to contribute significantly to the improvement of biochemical liquid handling for laboratory automation in terms of usability, miniaturization, cost reduction, and safety.

  11. Robust H∞ control for networked control systems

    Institute of Scientific and Technical Information of China (English)

    Ma Weiguo; Shao Cheng

    2008-01-01

    The robust H∞ control for networked control systems with both stochastic network-induced delay and data packet dropout is studied.When data are transmitted over network,the stochastic data packet dropout process can be described by a two-state Markov chain.The networked control systems with stochastic network-induced delay and data packet dropout are modeled as a discrete time Markov jump linear system with two operation modes.The sufficient condition of robust H∞ control for networked control systems stabilized by state feedback controller is presented in terms of linear matrix inequality.The state feedback controller can be constructed via the solution of a set of linear matrix inequalities.An example is given to verify the effectiveness of the method proposed.

  12. Fuel sensor-less control of a liquid feed fuel cell under dynamic loading conditions for portable power sources (I)

    Energy Technology Data Exchange (ETDEWEB)

    Chang, C.L. [Institute of Nuclear Energy Research (INER), No. 1000, Wunhua Road, Jiaan Village, Longtan Township, Taoyuan County 32546 (China); National Taiwan University (China); Chen, C.Y.; Liou, D.H. [Institute of Nuclear Energy Research (INER), No. 1000, Wunhua Road, Jiaan Village, Longtan Township, Taoyuan County 32546 (China); Sung, C.C. [National Taiwan University (China)

    2008-07-15

    This work presents a novel fuel sensor-less control scheme for a liquid feed fuel cell system that operates under dynamic loading conditions and is suitable for portable power sources. The proposed technique utilizes the operating characteristics of a fuel cell, such as voltage, current and power, to control the supply of liquid fuel and regulate its concentration. As verified by systematic experiments, this scheme controls effectively the supply of fuel under dynamic loading conditions and pushes the system toward higher power output. The primary features and advantages of sensor-less fuel control are as follows. When the fuel concentration sensor is excluded, the cost of a liquid feed fuel cell system is decreased and system volume and weight are reduced, thereby increasing specific energy density and design simplicity, and shortening system response time. Notably, temperature compensation for measurement data is unnecessary. With a decreased number of components, the control scheme improves durability and reliability of liquid feed fuel cells. These advantages will help commercialization of liquid feed fuel cells as portable power sources. (author)

  13. Experimental Investigations on the Interactions Between Liquids and Structures to Passively Control the Surface-Driven Capillary Flow in Microfluidic Lab-On Systems to Separate the Microparticles for Bioengineering Applications

    Science.gov (United States)

    Mukhopadhyay, Subhadeep

    In this research paper, total 246 individual microfluidic devices have been fabricated by maskless lithography, hot embossing lithography and direct bonding technique. The effect of surface area to volume ratio on the surface-driven capillary flow of different liquids has been experimentally investigated in these microfluidic devices fabricated by polymethylmethacrylate (PMMA). Also, the individual effects of liquid viscosity and surface wettability on the surface-driven capillary flow of different liquids are experimentally investigated. The polystyrene particles of 10μm diameters have been separated from the aqueous microparticle suspensions in the microfluidic lab-on-a-chip systems with 100% separation efficiency. Also, the polystyrene particles of 5μm diameters have been separated from a different set of aqueous microparticle suspensions in the microfluidic lab-on-a-chip systems with 100% separation efficiency. The individual designs of the microfluidic lab-on-a-chip systems are a novel approach in this research paper. The effect of surface area to volume ratio on the separation time is experimentally investigated as another novel approach of this research paper.

  14. Operational test report for 2706-T complex liquid transfer system

    Energy Technology Data Exchange (ETDEWEB)

    BENZEL, H.R.

    1999-09-01

    This document is the Operational Test Report (OTR). It enters the Record Copy of the W-259 Operational Test Procedure (HNF-3610) into the document retrieval system. Additionally, the OTR summarizes significant issues associated with testing the 2706-T waste liquid transfer and storage system.

  15. Liquid-Liquid Extraction-Chromogenic Systems Containing Iron(III), 4-Nitrocatechol and Tetrazolium Salts

    OpenAIRE

    Galya K. Toncheva; Teodora S. Stefanova; Gavazov, Kiril B.

    2015-01-01

    Complex formation and liquid-liquid extraction were studied in systems containing iron(III), 4-nitrocatechol (4NC),tetrazolium salt (TZS), water and organic solvent. Three different TZS were used: 3-(4,5-dimethyl-2-thiazol)-2,5-diphenyl-2H-tetrazolium bromide (MTT), 3-(2-naphtyl)-2,5-diphenyl-2H-tetrazolium chloride (Tetrazolium violet, TV) and 2-(4-iodophenyl)-3-(4-nitrophenyl)-5-phenyl-2H-tetrazolium chloride (INT).The cations of the first two TZSs (TZ+: MTT+ and TV+) form intensively color...

  16. For solid-liquid two phase softness abrasive flow embedded real-time monitoring and control system%面向固-液两相软性磨粒流嵌入式实时测控系统

    Institute of Scientific and Technical Information of China (English)

    计时鸣; 兰信鸿

    2012-01-01

    In order to solve the problems of flow pipe is to small to the conventional sensor for solid-liquid two phase softness abrasive flow,a monitoring method based on the vibration signal was proposed. Through the wavelet packet analysis of vibration signal, extraction signal characteristics were gotten. Using object-oriented technology, a kind of measurement and control software framework was developed, combined with finite state machine theory and embedded real-time operating system and programming methods of multitasking. Using Linux and DSP/BIOS RTOS, the double operating system signal processing technology was implemented,a multi-channel high speed data acquisition function was implemented on the intelligence embedded real-time measurement and control platform. The results indicate that it is easy to expand and interactive.%针对固-液两相软性磨粒流精密抛光方法中流道微小,无法采用常规直接信号传感器的问题,提出了一种基于二次信号-加速度振动信号的软性磨粒流监测方法.通过小波包分析提取了振动信号的特征.结合基于有限状态机理论与基于嵌入式实时操作系统的并发多任务的程序设计方法,采用面向对象技术开发了一种测控软件框架.采用Linux和DSP/BIOS RTOS实施了双操作系统信号处理技术,开发实现了一个面向软性磨粒流的,具有通用多通道高速数据采集功能的智能化嵌入式实时测控平台.研究结果表明,该系统具有易扩展与易交互的优点.

  17. New liquid aerosol generation devices: systems that force pressurized liquids through nozzles.

    Science.gov (United States)

    Geller, David E

    2002-12-01

    Over the past few decades, aerosol delivery devices have been relatively inefficient, wasteful, and difficult for patients to use. These drawbacks have been tolerated because the drugs available for inhalation have wide therapeutic margins and steep dose-response curves at low doses. Recently several forces have converged to drive innovation in the aerosol device industry: the ban on chlorofluorocarbon propellants in metered-dose inhalers, the need for more user-friendly devices, and the invention of expensive inhalable therapies for topical and systemic lung delivery. Numerous devices are in development to improve the efficiency, ease of use, and reproducibility of aerosol delivery to the lung, including systems that force liquid through a nozzle to form the aerosol cloud. The Respimat is a novel, compact, propellant-free, multi-dose inhaler that employs a spring to push drug solution through a nozzle, which generates a slow-moving aerosol. Deposition studies show that the Respimat can deliver 39-44% of a dose to the lungs. Clinical asthma and chronic obstructive pulmonary disease trials with bronchodilators show that the Respimat is 2-8 times as effective as a metered-dose inhaler. Respimat has been tested with bronchodilators and inhaled corticosteroids. The AERx device uses sophisticated electronics to deliver aerosol from a single-dose blister, using an integral, disposable nozzle array. The electronics control dose expression and titration, timing of aerosol generation with the breath, and provide feedback for proper inhalation technique. Lung deposition ranges from 50 to 80% of the loaded dose, with remarkable reproducibility. AERx has been tested with a variety of drugs, for both topical and systemic delivery, including rhDNase (dornase alfa), insulin, and opioids. These novel devices face competition from other technologies as well as financial and regulatory hurdles, but they both offer a marked improvement in the efficiency of pulmonary drug delivery.

  18. A moving mesh interface tracking method for simulation of liquid-liquid systems

    Science.gov (United States)

    Charin, A. H. L. M.; Tuković, Ž.; Jasak, H.; Silva, L. F. L. R.; Lage, P. L. C.

    2017-04-01

    This manuscript presents a moving mesh interface tracking procedure, with a novel treatment for phase coupling. The new coupling strategy allows accurate predictions for the interface behaviour in a wide range of macroscopic properties with great potential to explore liquid-liquid systems. In this approach, governing equations are applied to each phase individually while the interface is represented by a zero-thickness surface that contemplates inter-phase jumps. These equations are described in an arbitrary Lagrangian-Eulerian finite volume framework. Computations consider the pressure-corrector PISO method. The new treatment for phase coupling incorporates the interfacial jump updates within the pressure/velocity calculations. Additionally, cell-centred values from both phases are considered when calculating convective and diffusive terms at the interface. The employment of GGI (Generalized Grid-Interface) interpolation provides conservative data mapping between surfaces for non-conformal meshes. The prediction capability of the new formulation is evaluated under different dominant effects governing interface motion. Simulated cases include gravity and capillary waves in a sloshing tank, three-dimensional drop oscillation for liquid-liquid systems and drop deformation due to shear flow. The numerical results show good agreement with analytical transient profiles of interface position. The procedure is able to successfully represent systems with similar macroscopic properties, i.e. density and viscosity ratios approaching unity, and a broad range of interfacial tensions.

  19. Extraction of proteins with ionic liquid aqueous two-phase system based on guanidine ionic liquid.

    Science.gov (United States)

    Zeng, Qun; Wang, Yuzhi; Li, Na; Huang, Xiu; Ding, Xueqin; Lin, Xiao; Huang, Songyun; Liu, Xiaojie

    2013-11-15

    Eight kinds of green ionic liquids were synthesized, and an ionic liquid aqueous two-phase system (ILATPS) based on 1,1,3,3-tetramethylguandine acrylate (TMGA) guanidine ionic liquid was first time studied for the extraction of proteins. Single factor experiments proved that the extraction efficiency of bovine serum albumin (BSA) was influenced by the mass of IL, K2HPO4 and BSA, also related to the separation time and temperature. The optimum conditions were determined through orthogonal experiment by the five factors described above. The results showed that under the optimum conditions, the extraction efficiency could reach up to 99.6243%. The relative standard deviations (RSD) of extraction efficiencies in precision experiment, repeatability experiment and stability experiment were 0.8156% (n=5), 1.6173% (n=5) and 1.6292% (n=5), respectively. UV-vis and FT-IR spectra confirmed that there were no chemical interactions between BSA and ionic liquid in the extraction process, and the conformation of the protein was not changed after extraction. The conductivity, DLS and TEM were combined to investigate the microstructure of the top phase and the possible mechanism for the extraction. The results showed that hydrophobic interaction, hydrogen bonding interaction and the salt out effect played important roles in the transferring process, and the aggregation and embrace phenomenon was the main driving force for the separation. All these results proved that guanidine ionic liquid-based ATPSs have the potential to offer new possibility in the extraction of proteins.

  20. Second Order Sliding Mode Control of the Coupled Tanks System

    Directory of Open Access Journals (Sweden)

    Fayiz Abu Khadra

    2015-01-01

    Full Text Available Four classes of second order sliding mode controllers (2-SMC have been successfully applied to regulate the liquid level in the second tank of a coupled tanks system. The robustness of these classes of 2-SMC is investigated and their performances are compared with a first order controller to show the merits of these controllers. The effectiveness of these controllers is verified through computer simulations. Comparison between the controllers is based on the time domain performance measures such as rise time, settling time, and the integral absolute error. Results showed that controllers are able to regulate the liquid level with small differences in their performance.

  1. Pretreatment of Lignocellulosic Biomass with Ionic Liquids and Ionic Liquid-Based Solvent Systems

    OpenAIRE

    Qidong Hou; Meiting Ju; Weizun Li; Le Liu; Yu Chen; Qian Yang

    2017-01-01

    Pretreatment is very important for the efficient production of value-added products from lignocellulosic biomass. However, traditional pretreatment methods have several disadvantages, including low efficiency and high pollution. This article gives an overview on the applications of ionic liquids (ILs) and IL-based solvent systems in the pretreatment of lignocellulosic biomass. It is divided into three parts: the first deals with the dissolution of biomass in ILs and IL-based solvent systems; ...

  2. Controlled Cavitation in Microfluidic Systems

    NARCIS (Netherlands)

    Zwaan, Ed; le Gac, Severine; Tsuji, Kinko; Ohl, C.D.

    2007-01-01

    We report on cavitation in confined microscopic environments which are commonly called microfluidic or lab-on-a-chip systems. The cavitation bubble is created by focusing a pulsed laser into these structures filled with a lght-absorbing liquid. At hte center of a 20 mu m thick and 1 mm wide channel,

  3. Concept and System of Personification Control System

    Institute of Scientific and Technical Information of China (English)

    Bai,Fengshuang; Yin,Yixin; Tu,Xuyan; Zhang,Ying

    2006-01-01

    This paper provides the system and conception of the Personification Control System (PCS) on the basis of Intelligent Control System based on Artificial life (ICS/AL), Artificial Emotion, Humanoid Control, and Intelligent Control System based on Field bus. According to system science and deciding of organize of biology, the Pyramid System of PCS are created. Then Pyramid System of PCS which is made up of PCS1/H, PCS1/S, PCS1/O, PCS1/C and PCS1/G is described.

  4. The Effects of P, I and D Parameters in Automatic Liquid Level Control Using UniTrain Module

    Directory of Open Access Journals (Sweden)

    Alfatirta Mufti

    2013-04-01

    Full Text Available The research discusses some experiments to control the level of liquid inside a tank by using PID controllers which can be divided into four categories. The experiments describe the effect of P, I, and D element. It also discusses the best possible controller, which is a PI controller, for the liquid level tank system. The liquid level controlling is done by adjusting the voltage pump which will further regulate the flow rate of the fluid entering the inlet valve. The liquid that flows through the outlet valve is considered as the disturbance variable to the system. The liquid tank sensor needs to be calibrated prior to the experiments. Calibration can be done manually by using a digital multimeter or by using the computer sofware that is connected directly to the plant system. Set point and PID parameters are determined by the UniTrain and the computer interface. In these experiments, PI controller has the best result with a medium proportional gain (KP = 5 and a small integral gain (TN = 0.2.

  5. A reconfigurable liquid metal antenna driven by electrochemically controlled capillarity

    Energy Technology Data Exchange (ETDEWEB)

    Wang, M.; Adams, J. J., E-mail: jjadams2@ncsu.edu [Department of Electrical and Computer Engineering, North Carolina State University, Raleigh, North Carolina 27606 (United States); Trlica, C.; Khan, M. R.; Dickey, M. D. [Department of Chemical and Biomolecular Engineering, North Carolina State University, Raleigh, North Carolina 27606 (United States)

    2015-05-21

    We describe a new electrochemical method for reversible, pump-free control of liquid eutectic gallium and indium (EGaIn) in a capillary. Electrochemical deposition (or removal) of a surface oxide on the EGaIn significantly lowers (or increases) its interfacial tension as a means to induce the liquid metal in (or out) of the capillary. A fabricated prototype demonstrates this method in a reconfigurable antenna application in which EGaIn forms the radiating element. By inducing a change in the physical length of the EGaIn, the operating frequency of the antenna tunes over a large bandwidth. This purely electrochemical mechanism uses low, DC voltages to tune the antenna continuously and reversibly between 0.66 GHz and 3.4 GHz resulting in a 5:1 tuning range. Gain and radiation pattern measurements agree with electromagnetic simulations of the device, and its measured radiation efficiency varies from 41% to 70% over its tuning range.

  6. A magnetic suspension system for measuring liquid density

    Directory of Open Access Journals (Sweden)

    Luz María Centeno González

    2013-04-01

    Full Text Available Density is a derived quantity of mass and length; it is defined as mass per volume unit and its SI unit is kg/m3. National metrology institutes have been designing and building their own magnetic suspension systems during the last 5 decades for making fluid density measurements; this has allowed them to carry out research into liquids and gases’ physical characteristics. This paper was aimed at designing and developing a magnetic suspension system for a magnetic balance used in determining liquid density to be used in CENAM’s metrology density laboratories.

  7. Guaranteed cost control for networked control systems

    Institute of Scientific and Technical Information of China (English)

    Linbo XIE; Huajing FANG; Ying ZHENG

    2004-01-01

    The guaranteed cost control problem for networked control systems (NCSs) is addressed under communication constraints and varying sampling rate. First of all, a simple information-scheduling scheme is presented to describe the scheduling approach of system signals in NCSs. Then, based on such a scheme and given sampling method, the design procedure in dynamic output feedback manner is also derived which renders the closed loop system to be asymptotically stable and guarantees an upper bound of the LQ performance cost function.

  8. Optically controlled welding system

    Science.gov (United States)

    Gordon, Stephen S. (Inventor)

    1989-01-01

    An optically controlled welding system (10) wherein a welding torch (12) having through-the-torch viewing capabilities is provided with an optical beam splitter (56) to create a transmitted view and a reflective view of a welding operation. These views are converted to digital signals which are then processed and utilized by a computerized robotic welder (15) to make the welding torch responsive thereto. Other features includes an actively cooled electrode holder (26) which minimizes a blocked portion of the view by virtue of being constructed of a single spoke or arm (28) and a weld pool contour detector (14) comprising a laser beam directed onto the weld pool with the position of specular radiation reflected therefrom being characteristic of a penetrated or unpenetrated condition of the weld pool.

  9. Systemic Liquidity Shocks and Banking Sector Liquidity Characteristics on the Eve of Liquidity Coverage Ratio Application - The Case of the Czech Republic1

    Directory of Open Access Journals (Sweden)

    Brůna Karel

    2016-01-01

    Full Text Available The paper contains an analysis of the economic and regulatory concept of bank liquidity in the context of systemic liquidity shock. A formal model analysis shows that the application of liquidity coverage ratio (LCR based on Basel III will lead to a significant adaptation of banks liquidity management. LCR causes a change in bank’s liquidity allocation and funding to be less effective and more costly and restrictive for providing credits comparing with economic determinants. It is demonstrated that the application of LCR underestimates actual liquidity position of a bank and leads to allocation ineffectiveness. The empirical part contains simulation of impacts of systemic liquidity shock on the banking sector’s ability to withstand the unfavourable credit shock while solvency is maintained. The results confirm the robustness of the Czech banking system ensuing from the systemic surplus of liquidity, high volume of bank capital and its high profitability. The estimations of the VAR model show that the relations between liquidity characteristics of banks, sources of aggregate liquidity shock, interbank market illiquidity and the credit facilities of the Czech National Bank are relatively weak, supporting the conclusion that the banks face liquidity shocks of non-persistent character.

  10. Lignin-AuNPs liquid marble for remotely-controllable detection of Pb2+

    Science.gov (United States)

    Han, Guocheng; Wang, Xiaoying; Hamel, Jonathan; Zhu, Hongli; Sun, Runcang

    2016-12-01

    This work reported the green and facile fabrication of a versatile lignin-AuNP composite, which was readily and remotely encapsulated to form novel liquid marbles. The marbles can stay suspended in water, and show excellent photothermal conversion properties, as well as visual detection and adsorption towards Pb2+. More importantly, the marbles can simultaneously remotely detect and adsorb Pb2+ via co-precipitation by simply controlling the near infrared (NIR) irradiation. It is believed that the remotely-controllable NIR-responsive lignin-AuNPs liquid marble can be used in Pb2+-related reactions. The liquid marble can be placed in the system at the very beginning of the reaction and stably stays on the surface until the reaction has ended. After reacting, upon remote NIR irradiation, the liquid marble bursts to adsorb Pb2+, and the residual Pb2+ can be collected. This facile manipulation strategy does not use complicated nanostructures or sophisticated equipment, so it has potential applications for channel-free microfluidics, smart microreactors, microengines, and so on.

  11. Pretreatment of Lignocellulosic Biomass with Ionic Liquids and Ionic Liquid-Based Solvent Systems.

    Science.gov (United States)

    Hou, Qidong; Ju, Meiting; Li, Weizun; Liu, Le; Chen, Yu; Yang, Qian

    2017-03-20

    Pretreatment is very important for the efficient production of value-added products from lignocellulosic biomass. However, traditional pretreatment methods have several disadvantages, including low efficiency and high pollution. This article gives an overview on the applications of ionic liquids (ILs) and IL-based solvent systems in the pretreatment of lignocellulosic biomass. It is divided into three parts: the first deals with the dissolution of biomass in ILs and IL-based solvent systems; the second focuses on the fractionation of biomass using ILs and IL-based solvent systems as solvents; the third emphasizes the enzymatic saccharification of biomass after pretreatment with ILs and IL-based solvent systems.

  12. Liquid fuel utilization in SOFC hybrid systems

    Energy Technology Data Exchange (ETDEWEB)

    Santin, Marco; Traverso, Alberto; Magistri, Loredana [TPG-DIMSET, University of Genoa, Via Montallegro 1, 16145 Genoa (Italy)

    2009-10-15

    The interest in solid oxide fuel cell systems comes from their capability of converting the chemical energy of traditional fuels into electricity, with high efficiency and low pollutant emissions. In this paper, a study of the design space of solid oxide fuel cell and gas turbine hybrids fed by methanol and kerosene is presented for stationary power generation in isolated areas (or transportation). A 500 kW class hybrid system was analysed using WTEMP original software developed by the Thermochemical Power Group of the University of Genoa. The choice of fuel-processing strategy and the influence of the main design parameters on the thermoeconomic characteristics of hybrid systems were investigated. The low capital and fuel cost of methanol systems make them the most attractive solutions among those investigated here. (author)

  13. Liquid-crystal adaptive lenses with modal control.

    Science.gov (United States)

    Naumov, A F; Loktev, M Y; Guralnik, I R; Vdovin, G

    1998-07-01

    We report on a novel approach to the realization of nematic liquid-crystal (LC) phase correctors to form spherical and cylindrical wave fronts. A LC cell with a distributed reactive electrical impedance was driven by an ac voltage applied to the cell boundary to yield the desired spatial distribution of the refractive index. The two-dimensional function of the phase delay introduced into the light beam depends on the frequency of the ac control voltage, the geometry of the boundary electrode surrounding the LC cell, and the electrical parameters of the cell. We realized a cylindrical adaptive lens with a clear aperture of 15 mm x 4mm and a spherical adaptive lens with circular aperture of 6.5 mm. Both devices are capable of focusing collimated light in the range infinity...0.5 m.

  14. Nonresonant Multiple-Pulse Control of Molecular Motions in Liquid

    Directory of Open Access Journals (Sweden)

    Nikiforov V.G.

    2015-01-01

    Full Text Available We propose the implementation of the multiple-pulse excitation for manipulation of the molecular contributions to the optically-heterodyne-detected optical-Kerr-effect. The key parameters controlling the specificity of the multiple-pulse excitation scenarios are the pulses durations, the delays between pulses, the relation between the pump pulses amplitudes and the pulses polarizations. We model the high-order optical responses and consider some principles of the scenarios construction. We show that it is possible to adjust the excitation scenario in such a way that the some responses can be removed from detected signal along with the enhancement of the interested response amplitude. The theoretical analysis and first experimental data reveal that the multiple-pulse excitation technique can be useful for the selective spectroscopy of the molecular vibrations and rotations in liquid.

  15. System-level simulation of liquid filling in microfluidic chips.

    Science.gov (United States)

    Song, Hongjun; Wang, Yi; Pant, Kapil

    2011-06-01

    Liquid filling in microfluidic channels is a complex process that depends on a variety of geometric, operating, and material parameters such as microchannel geometry, flow velocity∕pressure, liquid surface tension, and contact angle of channel surface. Accurate analysis of the filling process can provide key insights into the filling time, air bubble trapping, and dead zone formation, and help evaluate trade-offs among the various design parameters and lead to optimal chip design. However, efficient modeling of liquid filling in complex microfluidic networks continues to be a significant challenge. High-fidelity computational methods, such as the volume of fluid method, are prohibitively expensive from a computational standpoint. Analytical models, on the other hand, are primarily applicable to idealized geometries and, hence, are unable to accurately capture chip level behavior of complex microfluidic systems. This paper presents a parametrized dynamic model for the system-level analysis of liquid filling in three-dimensional (3D) microfluidic networks. In our approach, a complex microfluidic network is deconstructed into a set of commonly used components, such as reservoirs, microchannels, and junctions. The components are then assembled according to their spatial layout and operating rationale to achieve a rapid system-level model. A dynamic model based on the transient momentum equation is developed to track the liquid front in the microchannels. The principle of mass conservation at the junction is used to link the fluidic parameters in the microchannels emanating from the junction. Assembly of these component models yields a set of differential and algebraic equations, which upon integration provides temporal information of the liquid filling process, particularly liquid front propagation (i.e., the arrival time). The models are used to simulate the transient liquid filling process in a variety of microfluidic constructs and in a multiplexer, representing a

  16. Coordination control of distributed systems

    CERN Document Server

    Villa, Tiziano

    2015-01-01

    This book describes how control of distributed systems can be advanced by an integration of control, communication, and computation. The global control objectives are met by judicious combinations of local and nonlocal observations taking advantage of various forms of communication exchanges between distributed controllers. Control architectures are considered according to  increasing degrees of cooperation of local controllers:  fully distributed or decentralized controlcontrol with communication between controllers,  coordination control, and multilevel control.  The book covers also topics bridging computer science, communication, and control, like communication for control of networks, average consensus for distributed systems, and modeling and verification of discrete and of hybrid systems. Examples and case studies are introduced in the first part of the text and developed throughout the book. They include: control of underwater vehicles, automated-guided vehicles on a container terminal, contro...

  17. Liquid cooling system for the vibro-tactile threshold device.

    Science.gov (United States)

    Parsons, Erin M; Redd, Christian; Gandhi, Minu S; Tuckett, Robert P; Bamberg, Stacy J Morris

    2011-01-01

    Vibrotactile threshold testing has been used to investigate activation of human somatosensory pathways. A portable vibrotactile threshold testing device called the Vibrotactile Threshold Evaluator for the Workplace (VTEW) was designed for screening of carpal tunnel syndrome in the workplace, and initially contained a small fan for cooling. During subject testing, the device is operated intermittently, which causes the linear actuator to warm the tactile probe. The probe causes discomfort for some subjects. During testing, the probe heated to 42 °C within 90 seconds of continuous operation. A liquid cooling system was implemented to dissipate heat from the probe. The liquid cooling system maintains a steady state temperature of 36 °C for continuous actuation of the probe. The liquid cooling system is capable of maintaining a safe operating temperature, without adding erroneous vibrations to the device. However, the cooling system deters the portability of the device. Further research will investigate how to make the liquid cooling system portable and implements vibrotactile threshold testing in the workplace to quickly evaluate whether or not a person has early symptoms of carpal tunnel syndrome.

  18. Division 1137 property control system

    Energy Technology Data Exchange (ETDEWEB)

    Pastor, D.J.

    1982-01-01

    An automated data processing property control system was developed by Mobile and Remote Range Division 1137. This report describes the operation of the system and examines ways of using it in operational planning and control.

  19. Generic device controller for accelerator control systems

    Energy Technology Data Exchange (ETDEWEB)

    Mariotti, R.; Buxton, W.; Frankel, R.; Hoff, L.

    1987-01-01

    A new distributed intelligence control system has become operational at the AGS for transport, injection, and acceleration of heavy ions. A brief description of the functionality of the physical devices making up the system is given. An attempt has been made to integrate the devices for accelerator specific interfacing into a standard microprocessor system, namely, the Universal Device Controller (UDC). The main goals for such a generic device controller are to provide: local computing power; flexibility to configure; and real time event handling. The UDC assemblies and software are described. (LEW)

  20. Impact of gate geometry on ionic liquid gated ionotronic systems

    Science.gov (United States)

    Wong, A. T.; Noh, J. H.; Pudasaini, P. R.; Wolf, B.; Balke, N.; Herklotz, A.; Sharma, Y.; Haglund, A. V.; Dai, S.; Mandrus, D.; Rack, P. D.; Ward, T. Z.

    2017-04-01

    Ionic liquid electrolytes are gaining widespread application as a gate dielectric used to control ion transport in functional materials. This letter systematically examines the important influence that device geometry in standard "side gate" 3-terminal geometries plays in device performance of a well-known oxygen ion conductor. We show that the most influential component of device design is the ratio between the area of the gate electrode and the active channel, while the spacing between these components and their individual shapes has a negligible contribution. These findings provide much needed guidance in device design intended for ionotronic gating with ionic liquids.

  1. On Restructurable Control System Theory

    Science.gov (United States)

    Athans, M.

    1983-01-01

    The state of stochastic system and control theory as it impacts restructurable control issues is addressed. The multivariable characteristics of the control problem are addressed. The failure detection/identification problem is discussed as a multi-hypothesis testing problem. Control strategy reconfiguration, static multivariable controls, static failure hypothesis testing, dynamic multivariable controls, fault-tolerant control theory, dynamic hypothesis testing, generalized likelihood ratio (GLR) methods, and adaptive control are discussed.

  2. Role of basicity and tetrahedral speciation in controlling the thermodynamic properties of silicate liquids, part 1: the system CaO-MgO-Al 2O 3-SiO 2

    Science.gov (United States)

    Beckett, John R.

    2002-01-01

    Activity coefficients of oxide components in the system CaO-MgO-Al 2O 3-SiO 2 (CMAS) were calculated with the model of Berman (Berman R. G., "A thermodynamic model for multicomponent melts with application to the system CaO-MgO-Al 2O 3-SiO 2," Ph.D. dissertation, University of British Columbia, 1983) and used to explore large-scale relationships among these variables and between them and the liquid composition. On the basis of Berman's model, the natural logarithm of the activity coefficient of MgO, ln(γ MgOLiq), and ln(γ MgOLiq/γ SiO 2Liq) are nearly linear functions of ln(γ CaOLiq). All three of these variables are simple functions of the optical basicity Λ with which they display minima near Λ ˜ 0.54 that are generated by liquids with low ratios of nonbridging to tetrahedral oxygens (NBO/T) (factor in determining the thermodynamic properties of aluminosilicate liquids. For a constant NBO/T, ln(γ CaOLiq/γ Al 2O 3Liq) and ln(γ MgOLiqγ Al 2O 3Liq) form curves in terms of X SiO 2Liq/X Al 2O 3Liq. The same liquids that generate minima in the Λ plots are also associated with minima in ln(γ CaOLiqγ Al 2O 3Liq) and ln(γ MgOLiqγ Al 2O 3Liq) as a function of X SiO 2Liq/X Al 2O 3Liq. In addition, there are maxima or sharp changes in slope for NBO/T > 0.3, which occur for X SiO 2Liq/X Al 2O 3Liq ranging from ˜0 to ˜6 and increase with increasing NBO/T. The systematic variations in activity coefficients as a function of composition and optical basicity reflect underlying shifts in speciation as the composition of the liquid is changed. On the basis of correlations among the activity coefficients, it is likely that the use of CaO, an exchange component such as SiMg -1 and two of MgO, CaAl 2O 4, or MgAl 2O 4 would yield significant savings in the number of parameters required to model the excess free energy surface of liquids over large portions of CMAS relative to the use of oxide end members. Systematic behavior of thermodynamic properties extends to small

  3. Ion adsorption components in liquid/solid systems

    Institute of Scientific and Technical Information of China (English)

    WU Xiao-fu; HU Yue-li; ZHAO Fang; HUANG Zhong-zi; LEI Dian

    2006-01-01

    Experiments on Zn2+ and Cd2+ adsorptions on vermiculite in aqueous solutions were conducted to investigate the widely observed adsorbent concentration effect on the traditionally defined adsorption isotherm in the adsorbate range 25-500 mg/L and adsorbent range 10-150 g/L. The results showed that the equilibrium ion adsorption density did not correspond to a unique equilibrium ion concentration in liquid phase. Three adsorbate/adsorbent ratios, the equilibrium adsorption density, the ratio of equilibrium adsorbate concentration in liquid phase to adsorbent concentration, and the ratio of initial adsorbate concentration to adsorbent concentration, were found to be related with unique values in the tested range. Based on the assumption that the equilibrium state of a liquid/solid adsorption system is determined by four mutually related components: adsorbate in liquid phase, adsorbate in solid phase, uncovered adsorption site and covered adsorption site, and that the equilibrium chemical potentials of these components should be equalized, a new model was presented for describing ion adsorption isotherm in liquid/solid systems. The proposed model fit well the experimental data obtained from the examined samples.

  4. Unimolecular Solvolyses in Ionic Liquid: Alcohol Dual Solvent Systems

    Directory of Open Access Journals (Sweden)

    Elizabeth D. Kochly

    2016-01-01

    Full Text Available A study was undertaken of the solvolysis of pivaloyl triflate in a variety of ionic liquid:alcohol solvent mixtures. The solvolysis is a kΔ process (i.e., a process in which ionization occurs with rearrangement, and the resulting rearranged carbocation intermediate reacts with the alcohol cosolvent via two competing pathways: nucleophilic attack or elimination of a proton. Five different ionic liquids and three different alcohol cosolvents were investigated to give a total of fifteen dual solvent systems. 1H-NMR analysis was used to determine relative amounts of elimination and substitution products. It was found, not surprisingly, that increasing the bulkiness of alcohol cosolvent led to increased elimination product. The change in the amount of elimination product with increasing ionic liquid concentration, however, varied greatly between ionic liquids. These differences correlate strongly, though not completely, to the Kamlet–Taft solvatochromic parameters of the hydrogen bond donating and accepting ability of the solvent systems. An additional factor playing into these differences is the bulkiness of the ionic liquid anion.

  5. Development of an Analytical Method Based on Temperature Controlled Solid-Liquid Extraction Using an Ionic Liquid as Solid Solvent

    Directory of Open Access Journals (Sweden)

    Zhongwei Pan

    2015-12-01

    Full Text Available At the present paper, an analytical method based on temperature controlled solid-liquid extraction (TC-SLE utilizing a synthesized ionic liquid, (N-butylpyridinium hexafluorophosphate, [BPy]PF6, as solid solvent and phenanthroline (PT as an extractant was developed to determine micro levels of Fe2+ in tea by PT spectrophotometry. TC-SLE was carried out in two continuous steps: Fe2+ can be completely extracted by PT-[BPy]PF6 or back-extracted at 80 °C and the two phases were separated automatically by cooling to room temperature. Fe2+, after back-extraction, needs 2 mol/L HNO3 as stripping agent and the whole process was determined by PT spectrophotometry at room temperature. The extracted species was neutral Fe(PTmCl2 (m = 1 according to slope analysis in the Fe2+-[BPy]PF6-PT TC-SLE system. The calibration curve was Y = 0.20856X − 0.000775 (correlation coefficient = 0.99991. The linear calibration range was 0.10–4.50 μg/mL and the limit of detection for Fe2+ is 7.0 × 10−2 μg/mL. In this method, the contents of Fe2+ in Tieguanyin tea were determined with RSDs (n = 5 3.05% and recoveries in range of 90.6%–108.6%.

  6. Parametric Analysis of a Rotary Type Liquid Desiccant Air Conditioning System

    Directory of Open Access Journals (Sweden)

    M. Mujahid Rafique

    2016-04-01

    Full Text Available Now days, air conditioning systems are a must for almost every commercial and residential building to achieve comfortable indoor conditions. The increasing energy demand, and increasing oil prices and pollution levels raise the need for alternative air conditioning systems which can efficiently utilize renewable energy resources. The liquid desiccant-based air conditioning method is pollution free and thermal energy-based cooling techniques can use low grade thermal energy resources like solar energy, waste heat, etc. These systems have an additional advantage of cleaning bacteria and fungi from the air. In this paper, a newly proposed rotary liquid desiccant air conditioning system has been investigated theoretically. Most direct contact liquid desiccant cooling systems have the problem of desiccant carryover which can be eliminated using the proposed system. The effects of various key parameters and climatic conditions on the performance of the system have been evaluated. The results showed that if the key parameters of the system are controlled effectively, the proposed cooling system has the ability to achieve the desired supply air conditions. The system can achieve high coefficient of performance (COP under different conditions. The dehumidifier has a sensible heat ratio (SHR in the range of 0.3–0.6 for different design, climatic, and operating conditions. The system can remove latent load efficiently in applications which require good humidity control.

  7. Liquid metal technology for concentrated solar power systems: Contributions by the German research program

    Directory of Open Access Journals (Sweden)

    Thomas Wetzel

    2014-03-01

    Full Text Available Concentrated solar power (CSP systems can play a major role as a renewable energy source with the inherent possibility of including a thermal energy storage subsystem for improving the plant dispatchability. Next-generation CSP systems have to provide an increased overall efficiency at reduced specific costs and they will require higher operating temperatures and larger heat flux densities. In that context, liquid metals are proposed as advanced high temperature heat transfer fluids, particularly for central receiver systems. Their main advantages are chemical stability at temperatures up to 900 ℃ and even beyond, as well as largely improved heat transfer when compared to conventional fluids like oil or salt mixtures, primarily due to their superior thermal conductivity. However, major issues here are the corrosion protection of structural materials and the development of technology components and control systems, as well as the development of indirect storage solutions, to circumvent the relatively small heat capacity of liquid metals. On the other hand, using liquid metals might enable alternative technologies like direct thermal-electric conversion or use of solar high-tem­perature heat in chemical processes. This article aims at describing research areas and research needs to be addressed for fully evaluating and subsequently utilizing the potential of liquid metals in CSP systems. A second aim of the article is a brief overview of the liquid metal research capabilities of Karlsruhe Institute of Technology (KIT, their background and their relation to CSP and the aforementioned research pathways.

  8. CONTROLLABILITY OF IOTA-2-SYSTEMS

    NARCIS (Netherlands)

    FAGNANI, F; WILLEMS, JC

    1992-01-01

    This paper is devoted to an investigation of controllability and almost controllability of l2-systems. These concepts are defined in terms of the possibility of steering one system trajectory to another. It is proved that a controllable l2-system always has finite memory The main result on almost co

  9. Networked control of microgrid system of systems

    Science.gov (United States)

    Mahmoud, Magdi S.; Rahman, Mohamed Saif Ur; AL-Sunni, Fouad M.

    2016-08-01

    The microgrid has made its mark in distributed generation and has attracted widespread research. However, microgrid is a complex system which needs to be viewed from an intelligent system of systems perspective. In this paper, a network control system of systems is designed for the islanded microgrid system consisting of three distributed generation units as three subsystems supplying a load. The controller stabilises the microgrid system in the presence of communication infractions such as packet dropouts and delays. Simulation results are included to elucidate the effectiveness of the proposed control strategy.

  10. Low heat-gain cryogenic-liquid transfer system

    Science.gov (United States)

    Hows, G. E.; Wright, B. J.

    1970-01-01

    Cryogenic-liquid transfer system, containing a ring structure with tensioned small diameter, high strength wires, provides adequate physical support for the piping, minimizes the conductive heat paths between the piping and jacket, and allows for thermal expansion and contraction of the piping.

  11. Gas-Liquid Supersonic Cleaning and Cleaning Verification Spray System

    Science.gov (United States)

    Parrish, Lewis M.

    2009-01-01

    NASA Kennedy Space Center (KSC) recently entered into a nonexclusive license agreement with Applied Cryogenic Solutions (ACS), Inc. (Galveston, TX) to commercialize its Gas-Liquid Supersonic Cleaning and Cleaning Verification Spray System technology. This technology, developed by KSC, is a critical component of processes being developed and commercialized by ACS to replace current mechanical and chemical cleaning and descaling methods used by numerous industries. Pilot trials on heat exchanger tubing components have shown that the ACS technology provides for: Superior cleaning in a much shorter period of time. Lower energy and labor requirements for cleaning and de-scaling uper.ninih. Significant reductions in waste volumes by not using water, acidic or basic solutions, organic solvents, or nonvolatile solid abrasives as components in the cleaning process. Improved energy efficiency in post-cleaning heat exchanger operations. The ACS process consists of a spray head containing supersonic converging/diverging nozzles, a source of liquid gas; a novel, proprietary pumping system that permits pumping liquid nitrogen, liquid air, or supercritical carbon dioxide to pressures in the range of 20,000 to 60,000 psi; and various hoses, fittings, valves, and gauges. The size and number of nozzles can be varied so the system can be built in configurations ranging from small hand-held spray heads to large multinozzle cleaners. The system also can be used to verify if a part has been adequately cleaned.

  12. Liquid / liquid biphasic electrochemistry in ultra-turrax dispersed acetonitrile / aqueous electrolyte systems

    Energy Technology Data Exchange (ETDEWEB)

    Watkins, John D. [Department of Chemistry, University of Bath, Claverton Down, Bath, BA2 7AY (United Kingdom); Amemiya, Fumihiro; Atobe, Mahito [Tokyo Institute of Technology, Department of Electronic Chemistry, Yokohama, Kanagawa 2268502 (Japan); Bulman-Page, Philip C. [School of Chemistry, University of East Anglia, Norwich, Norfolk NR4 7TJ (United Kingdom); Marken, Frank, E-mail: F.Marken@bath.ac.u [Department of Chemistry, University of Bath, Claverton Down, Bath, BA2 7AY (United Kingdom)

    2010-12-01

    Unstable acetonitrile | aqueous emulsions generated in situ with ultra-turrax agitation are investigated for applications in dual-phase electrochemistry. Three modes of operation for liquid / liquid aqueous-organic electrochemical processes are demonstrated with no intentionally added electrolyte in the organic phase based on (i) the formation of a water-soluble product in the aqueous phase in the presence of the organic phase, (ii) the formation of a product and ion transfer at the liquid / liquid-electrode triple phase boundary, and (iii) the formation of a water-insoluble product in the aqueous phase which then transfers into the organic phase. A three-electrode electrolysis cell with ultra-turrax agitator is employed and characterised for acetonitrile / aqueous 2 M NaCl two phase electrolyte. Three redox systems are employed in order to quantify the electrolysis cell performance. The one-electron reduction of Ru(NH{sub 3}){sub 6}{sup 3+} in the aqueous phase is employed to determine the rate of mass transport towards the electrode surface and the effect of the presence of the acetonitrile phase. The one-electron oxidation of n-butylferrocene in acetonitrile is employed to study triple phase boundary processes. Finally, the one-electron reduction of cobalticenium cations in the aqueous phase is employed to demonstrate the product transfer from the electrode surface into the organic phase. Potential applications in biphasic electrosynthesis are discussed.

  13. Statistical thermodynamics of liquid-liquid phase separation in ternary systems during complex coacervation

    Science.gov (United States)

    Pawar, Nisha; Bohidar, H. B.

    2010-09-01

    Liquid-liquid phase separation leading to complex coacervation in a ternary system (oppositely charged polyion and macroion in a solvent) is discussed within the framework of a statistical thermodynamics model. The polyion and the macroion in the ternary system interact to form soluble aggregates (complexes) in the solvent, which undergoes liquid-liquid phase separation. Four necessary conditions are shown to drive the phase separation: (i) (σ23)3r/Φ23c≥((64)/(9α2))(χ23Φ3)2 , (ii) r≥[(64(χ23Φ3)2)/(9α2σ233)]1/2 , (iii) χ23≥((2χ231-1))/(Φ23cΦ3) , and (iv) (σ23)2/I≥(8)/(3α)(2χ231-1) (where σ23 is the surface charge on the complex formed due to binding of the polyelectrolyte and macroion, Φ23c is the critical volume fraction of the complex, χ23 is the Flory interaction parameter between polyelectrolyte and macroion, χ231 is the same between solvent and the complex, Φ3 is the volume fraction of the macroions, I is the ionic strength of the solution, α is electrostatic interaction parameter and r is typically of the order of molecular weight of the polyions). It has been shown that coacervation always requires a hydrated medium. In the case of a colloidal macroion and polyelectrolyte coacervation, molecular weight of polyelectrolyte must satisfy the condition r≥103Da to exhibit liquid-liquid phase separation. This model has been successfully applied to study the coacervation phenomenon observed in aqueous Laponite (macroion)-gelatin (polyion) system where it was found that the coacervate volume fraction, δΦ23˜χ2312 (where δΦ23 is the volume fraction of coacervates formed during phase separation). The free energy and entropy of this process have been evaluated, and a free-energy landscape has been drawn for this system that maps the pathway leading to phase separation.

  14. Liquid crystalline systems for transdermal delivery of celecoxib: in vitro drug release and skin permeation studies.

    Science.gov (United States)

    Estracanholli, Eder André; Praça, Fabíola Silva Garcia; Cintra, Ana Beatriz; Pierre, Maria Bernadete Riemma; Lara, Marilisa Guimarães

    2014-12-01

    Liquid crystalline systems of monoolein/water could be a promising approach for the delivery of celecoxib (CXB) to the skin because these systems can sustain drug release, improve drug penetration into the skin layers and minimize side effects. This study evaluated the potential of these systems for the delivery of CXB into the skin based on in vitro drug release and skin permeation studies. The amount of CXB that permeated into and/or was retained in the skin was assayed using an HPLC method. Polarizing light microscopy studies showed that liquid crystalline systems of monoolein/water were formed in the presence of CXB, without any changes in the mesophases. The liquid crystalline systems decreased drug release when compared to control solution. Drug release was independent of the initial water content of the systems and CXB was released from cubic phase systems, irrespective of the initial water content. The systems released the CXB following zero-order release kinetics. In vitro drug permeation studies showed that cubic phase systems allowed drug permeation and retention in the skin layers. Cubic phase systems of monoolein/water may be promising vehicles for the delivery of CXB in/through the skin because it improved CXB skin permeation compared with the control solution.

  15. Reactor control rod timing system. [LMFBR

    Science.gov (United States)

    Wu, P.T.K.

    1980-03-18

    A fluid driven jet-edge whistle timing system is described for control rods of a nuclear reactor for producing real-time detection of the timing of each control rod in its scram operation. An important parameter in reactor safety, particularly for liquid metal fast breeder reactors (LMFBR), is the time deviation between the time the control rod is released and the time the rod actually reaches the down position. The whistle has a nearly pure tone signal with center frequency (above 100 kHz) far above the frequency band in which the energy of the background noise is concentrated. Each control rod can be fitted with a whistle with a different frequency so that there is no ambiguity in differentiating the signal from each control rod.

  16. The Combination of Micro Diaphragm Pumps and Flow Sensors for Single Stroke Based Liquid Flow Control.

    Science.gov (United States)

    Jenke, Christoph; Pallejà Rubio, Jaume; Kibler, Sebastian; Häfner, Johannes; Richter, Martin; Kutter, Christoph

    2017-04-03

    With the combination of micropumps and flow sensors, highly accurate and secure closed-loop controlled micro dosing systems for liquids are possible. Implementing a single stroke based control mode with piezoelectrically driven micro diaphragm pumps can provide a solution for dosing of volumes down to nanoliters or variable average flow rates in the range of nL/min to μL/min. However, sensor technologies feature a yet undetermined accuracy for measuring highly pulsatile micropump flow. Two miniaturizable in-line sensor types providing electrical readout-differential pressure based flow sensors and thermal calorimetric flow sensors-are evaluated for their suitability of combining them with mircopumps. Single stroke based calibration of the sensors was carried out with a new method, comparing displacement volumes and sensor flow volumes. Limitations of accuracy and performance for single stroke based flow control are described. Results showed that besides particle robustness of sensors, controlling resistive and capacitive damping are key aspects for setting up reproducible and reliable liquid dosing systems. Depending on the required average flow or defined volume, dosing systems with an accuracy of better than 5% for the differential pressure based sensor and better than 6.5% for the thermal calorimeter were achieved.

  17. Liquid-Liquid Equilibria of Ternary Systems cis-1,2-Dimethylcyclohexane+Toluene+Sulfolane☆

    Institute of Scientific and Technical Information of China (English)

    Xiaoyan Sun; Shuguang Xiang

    2014-01-01

    Liquid–Liquid Equilibrium (LLE) data for three Ternary Systems comprising cis-1,2-dimethylcyclohexane+toluene+sulfolane were measured at 298.15, 313.15 and 328.15 K under atmospheric pressure. The phase di-agrams for the ternary systems were presented. The reliability of the experiment data was tested using the Othmer–Tobias correlation. The LLE data were then correlated with the universal functional activity coefficient for liquid–liquid systems (UNIF-LL) and non-random two liquid using dataset 2 (NRTL/2) activity coefficient models to obtain the binary interaction parameters as programmed by the Aspen Plus simulation. The results showed that the experimental data were satisfactorily represented by both the UNIF-LL and the NRTL/2 models as revealed from the very smal values of the root mean square error and the absolute deviation in composition. © 2014 The Chemical Industry and Engineering Society of China, and Chemical Industry Press. Al rights reserved.

  18. System for controlling apnea

    Science.gov (United States)

    Holzrichter, John F

    2015-05-05

    An implanted stimulation device or air control device are activated by an external radar-like sensor for controlling apnea. The radar-like sensor senses the closure of the air flow cavity, and associated control circuitry signals (1) a stimulator to cause muscles to open the air passage way that is closing or closed or (2) an air control device to open the air passage way that is closing or closed.

  19. Smart Fluid Systems: The Advent of Autonomous Liquid Robotics.

    Science.gov (United States)

    Chiolerio, A; Quadrelli, Marco B

    2017-07-01

    Organic, inorganic or hybrid devices in the liquid state, kept in a fixed volume by surface tension or by a confining membrane that protects them from a harsh environment, could be used as biologically inspired autonomous robotic systems with unique capabilities. They could change shape according to a specific exogenous command or by means of a fully integrated adaptive system, and provide an innovative solution for many future applications, such as space exploration in extreme or otherwise challenging environments, post-disaster search and rescue in ground applications, compliant wearable devices, and even in the medical field for in vivo applications. This perspective provides an initial assessment of existing capabilities that could be leveraged to pursue the topic of "Smart Fluid Systems" or "Liquid Engineered Systems".

  20. Computer simulation of confined and flexoelectric liquid crystalline systems

    CERN Document Server

    Barmes, F

    2003-01-01

    In this Thesis, systems of confined and flexoelectric liquid crystal systems have been studied using molecular computer simulations. The aim of this work was to provide a molecular model of a bistable display cell in which switching is induced through the application of directional electric field pulses. In the first part of this Thesis, the study of confined systems of liquid crystalline particles has been addressed. Computation of the anchoring phase diagrams for three different surface interaction models showed that the hard needle wall and rod-surface potentials induce both planar and homeotropic alignment separated by a bistability region, this being stronger and wider for the rod-surface varant. The results obtained using the rod-sphere surface model, in contrast, showed that tilled surface arrangements can be induced by surface absorption mechanisms. Equivalent studies of hybrid anchored systems showed that a bend director structure can be obtained in a slab with monostable homeotropic anchoring at the...

  1. Air Liquide's pulse tube cryocooler systems for space applications

    Science.gov (United States)

    Trollier, T.; Tanchon, J.; Rey, J. C.; Ravex, A.; Buquet, J.

    2009-05-01

    Thanks to important development efforts completed internally and with the European Space Agency (ESA) funding, Air Liquide Advanced Technology Division (AL/DTA) is now in position to propose two Pulse Tube cooler systems in the 40-80K temperature range for coming Earth Observation missions such as Meteosat Third Generation (MTG), SIFTI, etc... The Miniature Pulse Tube Cooler (MPTC) is lifting up to 2.47W@80K with 50W maximal compressor input power and 10°C rejection temperature. The weight is 2.8 kg. The Large Pulse Tube Cooler (LPTC) is providing 2.3W@50K for 160W input power and 10°C rejection temperature. This product is weighing 5.1 kg. The two pulse tube coolers thermo-mechanical units are qualified against environmental constraints as per ESA ECSS-E-30. They are both using dual opposed pistons flexure bearing compressor with moving magnet linear motors in order to ensure very high lifetime. The associated Cooler Drive Electronics is also an important aspect specifically regarding the active control of the cooler thermo-mechanical unit during the launch phase and the active reduction of the vibrations induced by the compressor (partly supported by the French Agency CNES). This paper details the presentation of the two Pulse Tube Coolers together with the Cooler Drive Electronics aspects.

  2. Hydroponic system for the treatment of anaerobic liquid.

    Science.gov (United States)

    Krishnasamy, K; Nair, J; Bäuml, B

    2012-01-01

    The effluent from anaerobic digestion process has high concentrations of nutrients, particularly nitrogen, essential for plant growth but is not suitable for direct disposal or application due to high chemical oxygen demand (COD), low dissolved oxygen (DO), odour issues and is potentially phytotoxic. This research explored the optimum conditions of anaerobic effluent for application and dilutions of the effluent required to obtain better plant growth. A small-scale hydroponic system was constructed in a glasshouse to test different concentrations of anaerobic effluent against a commercial hydroponic medium as the control for the growth of silverbeet. It was found that the survival of silverbeet was negatively affected at 50% concentration due to low DO and NH(4) toxicity. The concentration of 20% anaerobic liquid was found to be the most efficient with highest foliage yield and plant growth. The hydroponic system with 20% concentrated effluent had better utilisation of nutrients for plant growth and a COD reduction of 95% was achieved during the 50-day growth period. This preliminary evaluation revealed that the growth and development of silverbeet was significantly lower in anaerobic effluent compared with a commercial hydroponic plant growth solution. The nutrient quality of anaerobic effluent could be highly variable with the process and the waste material used and dilution may depend on the nutrient content of the effluent. It is recommended that, a pre-treatment of the effluent to increase DO and reduce ammonium content is required before plant application, and simple dilution by itself is not suitable for optimum plant growth in a hydroponic system.

  3. Liquid-liquid and liquid-solid phase separation in protein-polyelectrolyte systems.

    Science.gov (United States)

    Comert, Fatih; Dubin, Paul L

    2017-01-01

    The coacervation of systems containing colloids (e.g. proteins or micelles) and polyelectrolytes (notably ionic polysaccharides) is often accompanied by precipitation. This can introduce inhomogeneity, irreversibility and irreproducible kinetics in applications in food science and bioengineering, with negative impact on texture and stability of food products, and unpredictable delivery of active "payloads." The relationship between coacervation and precipitation is obscure in that coacervates might be intermediates in the formation of precipitates, or else the two phenomena might proceed by different but possibly simultaneous mechanisms. This review will summarize the recent literature on coacervation/precipitation in protein-polyelectrolyte systems for which reports are most abundant, particularly in the context of food science. We present current findings and opinions about the relationship between the two types of phase separation. Results vary considerably depending not only on the protein-polyelectrolyte pairs chosen, but also on conditions including macromolecular concentrations and ionic strength. Nevertheless, we offer some general approaches that could explain a variety of observations. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Design of a controlled release liquid formulation of lamotrigine

    Directory of Open Access Journals (Sweden)

    V Kumar

    2011-05-01

    Full Text Available "n  "n  Background and the purpose of the study: Lamotrigine is a broad spectrum anticonvulsant drug widely used as mono- or adjunct- therapy in adults and children. The aim of this study was to develop controlled release liquid formulation of lamotrigine to improve bioavailability and compliance of pediatric and geriatric epileptic patients. "n  Methods: Multiple (w/o/w emulsion was prepared using one step emulsification technique. It was evaluated for entrapment efficiency (EE, morphology, zeta potential (ZP, polydispersity index (PI, rheology, thermal property, in vitro drug release behavior and stability. In vivo studies in albino mice were carried out using maximal electroshock seizure (MES test and strychnine induced seizure (SIS pattern test and results were compared with marketed formulation. "n  Results: The EE of the formulations varied from 84.37% to 98.11%. The ZP and PI values of the prepared batches were in the range of +23.46 to +28.07 and 0.256 and 0.365, respectively. Microscopic observation clearly indicated the stability of the emulsions during the storage period. All batches exhibited controlled in vitro drug release up to 12 hrs. Batch C11 exhibited significantly longer duration of protection of seizure in mice against MES and exhibited comparable efficacy in SIS as compared to the marketed formulation. "n  Major Conclusion: Multiple emulsion of lamotrigine compared to the marketed tablet showed plasma drug concentration within therapeutic range for longer time and comparable efficacy.

  5. Wettability and interfacial interactions in bioceramic-body-liquid systems.

    Science.gov (United States)

    Agathopoulos, S; Nikolopoulos, P

    1995-04-01

    Wetting experiments, by the sessile drop technique, were carried out at 37 degrees C in air to determine the surface and interfacial interactions that take place in various solid bioceramics based on Al2O3, ZrO2(YPZ), SiO2, and TiO2 in contact with water, Ringer solution, artificial synovial fluid, calf serum, human plasma, and whole blood (+ EDTA). The surface energy of the liquids was measured by the ring method. The calculated values of the energy of interaction (work of adhesion) reveal that intermolecular forces act across the solid-liquid interfaces. The contribution of the dispersion and polar interactions to the surface energy of the polar liquids and the pure or mixed oxides was determined assuming that in the system of Mn-steel-liquids only dispersion forces act at the interface. It was found that the contribution of the polar interactions to the energy of interaction at the solid-liquid interface increases with the glassy phase content of the oxide that causes reduction of the measured contact angle.

  6. Managing the inventory control system.

    Science.gov (United States)

    Daniels, C E

    1985-02-01

    The four functions of management--planning, organizing, directing, and controlling--are described in relation to the hospital pharmacy inventory control system. Planning includes the development of inventory system objectives and identification of the resources needed to complete them. Organizing requires the manager to decide on the best method of grouping system activities and resources to complete the objectives in order of priority. Directing is a continual activity that involves obtaining optimal performance from the inventory system resources available. Controlling consists of regulation and verification of inventory system activities. The effective inventory system manager integrates planning, organizing, directing, and controlling in a continuous cycle.

  7. Hybrid spacecraft attitude control system

    Directory of Open Access Journals (Sweden)

    Renuganth Varatharajoo

    2016-02-01

    Full Text Available The hybrid subsystem design could be an attractive approach for futurespacecraft to cope with their demands. The idea of combining theconventional Attitude Control System and the Electrical Power System ispresented in this article. The Combined Energy and Attitude ControlSystem (CEACS consisting of a double counter rotating flywheel assemblyis investigated for small satellites in this article. Another hybrid systemincorporating the conventional Attitude Control System into the ThermalControl System forming the Combined Attitude and Thermal ControlSystem (CATCS consisting of a "fluid wheel" and permanent magnets isalso investigated for small satellites herein. The governing equationsdescribing both these novel hybrid subsystems are presented and theironboard architectures are numerically tested. Both the investigated novelhybrid spacecraft subsystems comply with the reference missionrequirements.The hybrid subsystem design could be an attractive approach for futurespacecraft to cope with their demands. The idea of combining theconventional Attitude Control System and the Electrical Power System ispresented in this article. The Combined Energy and Attitude ControlSystem (CEACS consisting of a double counter rotating flywheel assemblyis investigated for small satellites in this article. Another hybrid systemincorporating the conventional Attitude Control System into the ThermalControl System forming the Combined Attitude and Thermal ControlSystem (CATCS consisting of a "fluid wheel" and permanent magnets isalso investigated for small satellites herein. The governing equationsdescribing both these novel hybrid subsystems are presented and theironboard architectures are numerically tested. Both the investigated novelhybrid spacecraft subsystems comply with the reference missionrequirements.

  8. Liquid equilibria in the Fe-Ni-Mn system

    Energy Technology Data Exchange (ETDEWEB)

    Schuermann, E. [Technische Univ. Clausthal, Clausthal-Zellerfeld (Germany). Inst. fuer Eisenhuettenkunde und Giessereiwesen; Djurdjevic, M.; Nedeljkovic, L. [Belgrade Univ. (Yugoslavia). Faculty of Technology and Metallurgy

    1997-12-01

    New literature results on the liquid equilibria in the three edge binary systems make necessary a reconsideration and correction of liquidus surfaces of the {gamma} and {delta} solid solutions hitherto outlined in the literature. Therefore, with respect to the critically reinterpreted edge binary systems, the shape of the stable liquidus surface of the {gamma} and {delta} solid solutions has been newly outlined. (orig.) 7 refs.

  9. Diagnostic, reliablility and control systems

    CERN Document Server

    Leondes

    2014-01-01

    1. Explicit-Model-Based Fault Detection Method in Industrial Plants 2. Soft Sensor: An Effective Approach to Improve Control 3. Techniques in Soft Computing and Their Utilization in Mechatronic Products 4. Techniques in the Control of Interconnected Plants 5. A Mechatronic Systems Approach to Controlling Robotic Systems with Actuator Dynamics 6. Process and Control Design for Fast Coordinate Measuring Machines 7. Techniques in the Stability of Mechatronic Systems with Sensor or Actuator Failure.

  10. Size Control and Fractionation of Ionic Liquid Filled Polymersomes with Glassy and Rubbery Bilayer Membranes.

    Science.gov (United States)

    So, Soonyong; Lodge, Timothy P

    2016-05-17

    We demonstrate control over the size of ionic liquid (IL) filled polymeric vesicles (polymersomes) by three distinct methods: mechanical extrusion, cosolvent-based processing in an IL, and fractionation of polymersomes in a biphasic system of IL and water. For the representative ionic liquid (1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl) imide ([EMIM][TFSI])), the size and dispersity of polymersomes formed from 1,2-polybutadiene-b-poly(ethylene oxide) (PB-PEO) and polystyrene-b-poly(ethylene oxide) (PS-PEO) diblock copolymers were shown to be sensitive to assembly conditions. During mechanical extrusion through a polycarbonate membrane, the relatively larger polymersomes were broken up and reorganized into vesicles with mean size comparable to the membrane pore (100 nm radius); the distribution width also decreased significantly after only a few passes. Other routes were studied using the solvent-switch or cosolvent (CS) method, whereby the initial content of the cosolvent and the PEO block length of PS-PEO were systemically changed. The nonvolatility of the ionic liquid directly led to the desired concentration of polymersomes in the ionic liquid using a single step, without the dialysis conventionally used in aqueous systems, and the mean vesicle size depended on the amount of cosolvent employed. Finally, selective phase transfer of PS-PEO polymersomes based on size was used to extract larger polymersomes from the IL to the aqueous phase via interfacial tension controlled phase transfer. The interfacial tension between the PS membrane and the aqueous phase was varied with the concentration of sodium chloride (NaCl) in the aqueous phase; then the larger polymersomes were selectively separated to the aqueous phase due to differences in shielding of the hydrophobic core (PS) coverage by the hydrophilic corona brush (PEO). This novel fractionation is a simple separation process without any special apparatus and can help to prepare monodisperse polymersomes

  11. Space Shuttle flight control system

    Science.gov (United States)

    Klinar, W. J.; Kubiak, E. T.; Peters, W. H.; Saldana, R. L.; Smith, E. E., Jr.; Stegall, H. W.

    1975-01-01

    The Space Shuttle is a control stabilized vehicle with control provided by an all digital, fly-by-wire flight control system. This paper gives a description of the several modes of flight control which correspond to the Shuttle mission phases. These modes are ascent flight control (including open loop first stage steering, the use of four computers operating in parallel and inertial guidance sensors), on-orbit flight control (with a discussion of reaction control, phase plane switching logic, jet selection logic, state estimator logic and OMS thrust vector control), entry flight control and TAEM (terminal area energy management to landing). Also discussed are redundancy management and backup flight control.

  12. Liquid Cooling System for CPU by Electroconjugate Fluid

    Directory of Open Access Journals (Sweden)

    Yasuo Sakurai

    2014-06-01

    Full Text Available The dissipated power of CPU for personal computer has been increased because the performance of personal computer becomes higher. Therefore, a liquid cooling system has been employed in some personal computers in order to improve their cooling performance. Electroconjugate fluid (ECF is one of the functional fluids. ECF has a remarkable property that a strong jet flow is generated between electrodes when a high voltage is applied to ECF through the electrodes. By using this strong jet flow, an ECF-pump with simple structure, no sliding portion, no noise, and no vibration seems to be able to be developed. And then, by the use of the ECF-pump, a new liquid cooling system by ECF seems to be realized. In this study, to realize this system, an ECF-pump is proposed and fabricated to investigate the basic characteristics of the ECF-pump experimentally. Next, by utilizing the ECF-pump, a model of a liquid cooling system by ECF is manufactured and some experiments are carried out to investigate the performance of this system. As a result, by using this system, the temperature of heat source of 50 W is kept at 60°C or less. In general, CPU is usually used at this temperature or less.

  13. Electro-optical switching by liquid-crystal controlled metasurfaces

    CERN Document Server

    Decker, Manuel; Minovich, Alexander; Staude, Isabelle; Miroshnichenko, Andrey E; Chigrin, Dmitry; Neshev, Dragomir N; Jagadish, Chennupati; Kivshar, Yuri S

    2013-01-01

    We study the optical response of a metamaterial surface created by a lattice of split-ring resonators covered with a nematic liquid crystal and demonstrate millisecond timescale switching between electric and magnetic resonances of the metasurface. This is achieved due to a high sensitivity of liquid-crystal molecular reorientation to the symmetry of the metasurface as well as to the presence of a bias electric field. Our experiments are complemented by numerical simulations of the liquid-crystal reorientation.

  14. Non-linear and adaptive control of a refrigeration system

    DEFF Research Database (Denmark)

    Rasmussen, Henrik; Larsen, Lars F. S.

    2011-01-01

    In a refrigeration process heat is absorbed in an evaporator by evaporating a flow of liquid refrigerant at low pressure and temperature. Controlling the evaporator inlet valve and the compressor in such a way that a high degree of liquid filling in the evaporator is obtained at all compressor...... are capable of adapting to variety of systems. This paper proposes a novel method for superheat and capacity control of refrigeration systems; namely by controlling the superheat by the compressor speed and capacity by the refrigerant flow. A new low order nonlinear model of the evaporator is developed...

  15. Analysis of Liquid Zone Control Valve Oscillation Problem in CANDU Reactors

    Directory of Open Access Journals (Sweden)

    Elnara Nasimi

    2013-01-01

    Full Text Available This paper looks at the existing challenges with steady-state Liquid Zone control at some CANDU (CANada Deuterium Uranium stations, where—contrary to expectations for equilibrium flow—Liquid Zone Control Valve oscillations have proven to be a chronic, unanticipated challenge. Currently, the exact causes of this behaviour are not fully understood, although it is confirmed that the Control Valve oscillations are not due to automatic power adjustment requests or zone level changes due to process leaks. This phenomenon was analysed based on a case study of one domestic nuclear power station to determine whether it could be attributed to inherent controller properties. Next, a proposal is made in an attempt to improve current performance with minimal changes to the existing system hardware and logic using conventional technologies. Finally, a proposal was made to consider Model Predictive Control-based technology to minimize the undesirable Control Valve oscillations at steady state based on the obtained simulation results and discussion of other available alternatives.

  16. Liquid flexRIXS: A RIXS endstation for molecular systems at BESSY II

    OpenAIRE

    2016-01-01

    The liquid flexRIXS endstation is dedicated to resonant inelastic x-ray scattering experiments on liquid samples and gasses in the soft x-ray range. The liquids are injected into the chamber via a liquid jet system whereas gasses and also small amounts of liquids can be investigated using a liquid/gas flow cell. The MCP-based RIXS spectrometer allows for a resolving power of better than 1000.

  17. Thermodynamic Vent System Performance Testing with Subcooled Liquid Methane and Gaseous Helium Pressurant

    Science.gov (United States)

    Flachbart, R. H.; Hastings, L. J.; Hedayat, A.; Nelson, S. L.; Tucker, S. P.

    2007-01-01

    Due to its high specific impulse and favorable thermal properties for storage, liquid methane (LCH4) is being considered as a candidate propellant for exploration architectures. In order to gain an -understanding of any unique considerations involving micro-gravity pressure control with LCH4, testing was conducted at the Marshall Space Flight Center using the Multipurpose Hydrogen Test Bed (MHTB) to evaluate the performance of a spray-bar thermodynamic vent system (TVS) with subcooled LCH4 and gaseous helium (GHe) pressurant. Thirteen days of testing were performed in November 2006, with total tank heat leak conditions of about 715 W and 420 W at a fill level of approximately 90%. The TVS system was used to subcool the LCH4 to a liquid saturation pressure of approximately 55.2 kPa before the tank was pressurized with GHe to a total pressure of 165.5 kPa. A total of 23 TVS cycles were completed. The TVS successfully controlled the ullage pressure within a prescribed control band but did not maintain a stable liquid saturation pressure. This was likely. due to a TVS design not optimized for this particular propellant and test conditions, and possibly due to a large artificially induced heat input directly into the liquid. The capability to reduce liquid saturation pressure as well as maintain it within a prescribed control band, demonstrated that the TVS could be used to seek and maintain a desired liquid inlet temperature for an engine (at a cost of propellant lost through the TVS vent). One special test was conducted at the conclusion of the planned test activities. Reduction of the tank ullage pressure by opening the Joule-Thomson valve (JT) without operating the pump was attempted. The JT remained open for over 9300 seconds, resulting in an ullage pressure reduction of 30 kPa. The special test demonstrated the feasibility of using the JT valve for limited ullage pressure reduction in the event of a pump failure.

  18. Liquid crystal devices especially for use in liquid crystal point diffraction interferometer systems

    Science.gov (United States)

    Marshall, Kenneth L [Rochester, NY

    2009-02-17

    Liquid crystal point diffraction interferometer (LCPDI) systems that can provide real-time, phase-shifting interferograms that are useful in the characterization of static optical properties (wavefront aberrations, lensing, or wedge) in optical elements or dynamic, time-resolved events (temperature fluctuations and gradients, motion) in physical systems use improved LCPDI cells that employ a "structured" substrate or substrates in which the structural features are produced by thin film deposition or photo resist processing to provide a diffractive element that is an integral part of the cell substrate(s). The LC material used in the device may be doped with a "contrast-compensated" mixture of positive and negative dichroic dyes.

  19. D0 Cryo System Control System Autodialer

    Energy Technology Data Exchange (ETDEWEB)

    Urbin, J.; /Fermilab

    1990-04-17

    The DO cryogenic system is controlled by a TI565-PLC based control system. This allows the system to be unmanned when in steady state operation. System experts will need to be contacted when system parameters exceed normal operating points and reach alarm setpoints. The labwide FIRUS system provides one alarm monitor and communication link. An autodialer provides a second and more flexible alarm monitor and communication link. The autodialer monitors contact points in the control system and after receiving indication of an alarm accesses a list of experts which it calls until it receives an acknowledgement. There are several manufacturers and distributors of autodialer systems. This EN explains the search process the DO cryo group used to fmd an autodialer system that fit the cryo system's needs and includes information and specs for the unit we chose.

  20. Liquid-Liquid Extraction-Chromogenic Systems Containing Iron(III, 4-Nitrocatechol and Tetrazolium Salts

    Directory of Open Access Journals (Sweden)

    Galya K. Toncheva

    2015-03-01

    Full Text Available Complex formation and liquid-liquid extraction were studied in systems containing iron(III, 4-nitrocatechol (4NC,tetrazolium salt (TZS, water and organic solvent. Three different TZS were used: 3-(4,5-dimethyl-2-thiazol-2,5-diphenyl-2H-tetrazolium bromide (MTT, 3-(2-naphtyl-2,5-diphenyl-2H-tetrazolium chloride (Tetrazolium violet, TV and 2-(4-iodophenyl-3-(4-nitrophenyl-5-phenyl-2H-tetrazolium chloride (INT.The cations of the first two TZSs (TZ+: MTT+ and TV+ form intensively colored (molar absorptivity of 4.6´104 L mol–1 cm–1 and 4.4´104 L mol–1 cm–1, respectively chloroform extractable ion-associates with the FeIII-4NC anionic chelate. These ternary complexes can be represented with the following general formula: (TZ+3[FeIII(4NC3]3−.

  1. Measurement of liquid-liquid equilibria for condensate + glycol and condensate + glycol + water systems

    DEFF Research Database (Denmark)

    Riaz, Muhammad; Kontogeorgis, Georgios; Stenby, Erling Halfdan

    2011-01-01

    Today's oil and gas production requires the application of various chemicals in large amounts. To evaluate the effects of those chemicals on the environment, it is of crucial importance to know how much of the chemicals are discharged via produced water and how much is dissolved in the crude oil....... The ultimate objective of this work is to develop a predictive thermodynamic model for the mutual solubility of oil, water, and polar chemicals. But for the development and validation of the model, experimental data are required. This work presents new experimental liquid-liquid equilibrium (LLE) data for 1......,2-ethanediol (MEG) + condensate and MEG + water + condensate systems at temperatures from (275 to 323) K at atmospheric pressure. The condensate used in this work is a stabilized natural gas condensate from an offshore field in the North Sea. Compositional analysis of the natural gas condensate was carried out...

  2. Controlling frustrated liquids and solids with an applied field in a kagome Heisenberg antiferromagnet.

    Science.gov (United States)

    Nishimoto, Satoshi; Shibata, Naokazu; Hotta, Chisa

    2013-01-01

    Quantum spin-1/2 kagome Heisenberg antiferromagnet is the representative frustrated system possibly hosting a spin liquid. Clarifying the nature of this elusive topological phase is a key challenge in condensed matter; however, even identifying it still remains unsettled. Here we apply a magnetic field and discover a series of spin-gapped phases appearing at five different fractions of magnetization by means of a grand canonical density matrix renormalization group, an unbiased state-of-the-art numerical technique. The magnetic field dopes magnons and first gives rise to a possible Z₃ spin liquid plateau at 1/9 magnetization. Higher field induces a self-organized super-lattice unit, a six-membered ring of quantum spins, resembling an atomic orbital structure. Putting magnons into this unit one by one yields three quantum solid plateaus. We thus find that the magnetic field could control the transition between various emergent phases by continuously releasing the frustration.

  3. Ion Transfer Voltammetry Associated with Two Polarizable Interfaces Within Water and Moderately Hydrophobic Ionic Liquid Systems

    DEFF Research Database (Denmark)

    Gan, Shiyu; Zhou, Min; Zhang, Jingdong;

    2013-01-01

    An electrochemical system composed of two polarizable interfaces (the metallic electrode|water and water|ionic liquid interfaces), namely two‐polarized‐interface (TPI) technique, has been proposed to explore the ion transfer processes between water and moderately hydrophobic ionic liquids (W...... to an extremely narrow polarized potential window (ppw) caused by these moderately hydrophobic ionic components. In this article, we show that TPI technique has virtually eliminated the ppw limitation based on a controlling step of concentration polarization at the electrode|water interface. With the aid...

  4. Possibilities of Thermal Systems Control

    Directory of Open Access Journals (Sweden)

    Renata WAGNEROVÁ

    2009-06-01

    Full Text Available This contribution describes different approaches to thermal system control. Not only PID control but also sliding mode controls were used. In addition the different modifications of sliding mode control were used, such as extension with integral element or continuous substitution of sign function. Considering the thermal system allows applying cooling element, the control algorithm using cooling and heating parts was tested too. All designed algorithms were verified with help of computer simulation and also directly on laboratory stand. All used control algorithms ensured required temperature but with different control quality.

  5. Cylindrical liquid crystal lenses system for autostereoscopic 2D/3D display

    Science.gov (United States)

    Chen, Chih-Wei; Huang, Yi-Pai; Chang, Yu-Cheng; Wang, Po-Hao; Chen, Po-Chuan; Tsai, Chao-Hsu

    2012-06-01

    The liquid crystal lenses system, which could be electrically controlled easily for autostereoscopic 2D/3D switchable display was proposed. The High-Resistance liquid crystal (HRLC) lens utilized less controlled electrodes and coated a high-resistance layer between the controlled-electrodes was proposed and was used in this paper. Compare with the traditional LC lens, the HR-LC Lens could provide smooth electric-potential distribution within the LC layer under driving status. Hence, the proposed HR-LC Lens had less circuit complexity, low driving voltage, and good optical performance also could be obtained. In addition, combining with the proposed driving method called dual-directional overdriving method, the above method could reduce the switching time by applying large voltage onto cell. Consequently, the total switching time could be further reduced to around 2second. It is believed that the LC lens system has high potential in the future.

  6. Combined effect of hemipteran control and liquid bait on Argentine ant populations.

    Science.gov (United States)

    Brightwell, R J; Bambara, S B; Silverman, J

    2010-10-01

    The invasive Argentine ant, Linepithema humile (Mayr), has become a worldwide problem capable of inflicting significant ecological and economic injury on urban, agricultural, and natural environments. The mobility of this pest ant has long been noted, rapidly moving nests to new food resources and then away as resources are depleted. This ant, like many pest ant species, has a special affinity for honeydew excreted by phloem-feeding Hemiptera. We investigated the effect of various hemipteran control strategies on terrapin scale densities and measured their indirect effect on local Argentine ant densities and foraging effort. We then determined whether this indirect treatment strategy improved the performance of an ant bait. We predicted that Argentine ants would move nests away from trees treated for Hemiptera and then move nests back when a liquid bait was offered, followed by a decline in ant numbers due to intake of the toxicant. A horticultural oil spray and soil application of the systemic insecticide, imidacloprid, had no effect on terrapin scale numbers. However, trunk-injected dicrotophos caused a reduction in scale and a decline in local Argentine ant nest density and canopy foraging effort. We also recorded a reduction in local Argentine ant ground foraging when large amounts of liquid bait were applied, and we found no evidence that combining dicrotophos with liquid ant bait performed better than each treatment alone. We suggest that a strategy of combined hemipteran control plus application of liquid ant bait can reduce local Argentine ant densities, when both components of this system are highly efficacious.

  7. Renewable Liquid Optics with Magneto-electrostatic Control

    Energy Technology Data Exchange (ETDEWEB)

    Ryutov, D; Toor, A

    2001-06-25

    We suggest a new class of high-flux renewable optics, in particular, for the use at the X-ray free electron laser, LCLS, which is under discussion now. The size of optical elements we have in mind is from a fraction of a square centimeter to a few square centimeters. We suggest that working fluid be pressed through a porous substrate (made, e.g., of fused capillaries) to form a film, a few tens to a hundred microns thick. After the passage of an intense laser pulse, the liquid film is sucked back through the substrate by a reversed motion of the piston, and formed anew before the next pulse. The working surface of the film is made flat by capillary forces. We discuss the role of viscous, gravitational, and capillary forces in the dynamics of the film and show that the properly made film can be arbitrarily oriented with respect to the gravitational force. This makes the proposed optics very flexible. We discuss effects of vibrations of the supporting structures on the quality of optical elements. Limitations on the radiation intensity are formulated. We show how the shape of the film surface can be controlled by electrostatic and magnetic forces, allowing one to make parabolic mirrors and reflecting diffraction gratings.

  8. Delays and networked control systems

    CERN Document Server

    Hetel, Laurentiu; Daafouz, Jamal; Johansson, Karl

    2016-01-01

    This edited monograph includes state-of-the-art contributions on continuous time dynamical networks with delays. The book is divided into four parts. The first part presents tools and methods for the analysis of time-delay systems with a particular attention on control problems of large scale or infinite-dimensional systems with delays. The second part of the book is dedicated to the use of time-delay models for the analysis and design of Networked Control Systems. The third part of the book focuses on the analysis and design of systems with asynchronous sampling intervals which occur in Networked Control Systems. The last part of the book exposes several contributions dealing with the design of cooperative control and observation laws for networked control systems. The target audience primarily comprises researchers and experts in the field of control theory, but the book may also be beneficial for graduate students. .

  9. ON COMPLEX DYNAMIC CONTROL SYSTEMS

    Institute of Scientific and Technical Information of China (English)

    CHENG Daizhan

    2003-01-01

    This paper presents some recent works on the control of dynamic systems, which have certain complex properties caused by singularity of the nonlinear structures, structure-varyings, or evolution process etc. First, we consider the structure singularity of nonlinear control systems. It was revealed that the focus of researches on nonlinear control theory is shifting from regular systems to singular systems. The singularity of nonlinear systems causes certain complexity. Secondly, the switched systems are considered. For such systems the complexity is caused by the structure varying. We show that the switched systems have significant characteristics of complex systems. Finally, we investigate the evolution systems. The evolution structure makes complexity, and itself is a proper model for complex systems.

  10. Control integral systems; Sistemas integrales de control

    Energy Technology Data Exchange (ETDEWEB)

    Burgos, Estrella [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1998-12-31

    Almost two third of the electric power generation in Mexico are obtained from hydrocarbons, for that reasons Comision Federal de Electricidad (CFE) dedicated special commitment in modernizing the operation of fossil fuel central stations. In attaining this objective the control systems play a fundamental roll, from them depend a good share of the reliability and the efficiency of the electric power generation process, as well as the extension of the equipment useful life. Since 1984 the Instituto de Investigaciones Electricas (IIE) has been working, upon the request of CFE, on the development of digital control systems. To date it has designed and implemented a logic control system for gas burners, which controls 32 burners of the Unit 4 boiler of the Generation Central of Valle de Mexico and two systems for distributed control for two combined cycle central stations, which are: Dos Bocas, Veracruz Combined cycle central, and Gomez Palacio, Durango combined cycle central. With these two developments the IIE enters the World tendency of implementing distributed control systems for the fossil fuel power central update [Espanol] Casi las dos terceras partes de la generacion electrica en Mexico se obtienen a partir de hidrocarburos, es por eso que la Comision Federal de Electricidad (CFE) puso especial empeno en modernizar la operacion de las centrales termoelectricas de combustibles fosiles. En el logro de este objetivo los sistemas de control desempenan un papel fundamental, de ellos depende una buena parte la confiabilidad y la eficiencia en el proceso de generacion de energia electrica, asi como la prolongacion de la vida util de los equipos. Desde 1984 el Instituto de Investigaciones Electricas (IIE) ha trabajado, a solicitud de la CFE, en el desarrollo de sistemas digitales de control. A la fecha se han disenado e implantado un sistema de control logico de quemadores de gas, el cual controla 32 quemadores de la caldera de la unidad 4 de la central de generacion

  11. Optimal Control of Mechanical Systems

    OpenAIRE

    Vadim Azhmyakov

    2007-01-01

    In the present work, we consider a class of nonlinear optimal control problems, which can be called “optimal control problems in mechanics.” We deal with control systems whose dynamics can be described by a system of Euler-Lagrange or Hamilton equations. Using the variational structure of the solution of the corresponding boundary-value problems, we reduce the initial optimal control problem to an auxiliary problem of multiobjective programming. This technique makes it possible to apply some ...

  12. Asynchronous control for networked systems

    CERN Document Server

    Rubio, Francisco; Bencomo, Sebastián

    2015-01-01

    This book sheds light on networked control systems; it describes different techniques for asynchronous control, moving away from the periodic actions of classical control, replacing them with state-based decisions and reducing the frequency with which communication between subsystems is required. The text focuses specially on event-based control. Split into two parts, Asynchronous Control for Networked Systems begins by addressing the problems of single-loop networked control systems, laying out various solutions which include two alternative model-based control schemes (anticipatory and predictive) and the use of H2/H∞ robust control to deal with network delays and packet losses. Results on self-triggering and send-on-delta sampling are presented to reduce the need for feedback in the loop. In Part II, the authors present solutions for distributed estimation and control. They deal first with reliable networks and then extend their results to scenarios in which delays and packet losses may occur. The novel ...

  13. Pretreatment of Lignocellulosic Biomass with Ionic Liquids and Ionic Liquid-Based Solvent Systems

    Directory of Open Access Journals (Sweden)

    Qidong Hou

    2017-03-01

    Full Text Available Pretreatment is very important for the efficient production of value-added products from lignocellulosic biomass. However, traditional pretreatment methods have several disadvantages, including low efficiency and high pollution. This article gives an overview on the applications of ionic liquids (ILs and IL-based solvent systems in the pretreatment of lignocellulosic biomass. It is divided into three parts: the first deals with the dissolution of biomass in ILs and IL-based solvent systems; the second focuses on the fractionation of biomass using ILs and IL-based solvent systems as solvents; the third emphasizes the enzymatic saccharification of biomass after pretreatment with ILs and IL-based solvent systems.

  14. Gas Transport and Control in Thick-Liquid Inertial Fusion PowerPlants

    Energy Technology Data Exchange (ETDEWEB)

    Debonnel, Christophe Sylvain [Univ. of California, Berkeley, CA (United States)

    2006-01-01

    Among the numerous potential routes to a commercial fusion power plant, the inertial path with thick-liquid protection is explored in this doctoral dissertation. Gas dynamics phenomena in such fusion target chambers have been investigated since the early 1990s with the help of a series of simulation codes known as TSUNAMI. For this doctoral work, the code was redesigned and rewritten entirely to enable the use of modern programming techniques, languages and software; improve its user-friendliness; and refine its ability to model thick-liquid protected chambers. The new ablation and gas dynamics code is named “Visual Tsunami” to emphasize its graphics-based pre- and post-processors. It is aimed at providing a versatile and user-friendly design tool for complex systems for which transient gas dynamics phenomena play a key role. Simultaneously, some of these improvements were implemented in a previous version of the code; the resulting code constitutes the version 2.8 of the TSUNAMI series. Visual Tsunami was used to design and model the novel Condensation Debris Experiment (CDE), which presents many aspects of a typical Inertial Fusion Energy (IFE) system and has therefore been used to exercise the code. Numerical and experimental results are in good agreement. In a heavy-ion IFE target chamber, proper beam and target propagation set stringent requirements for the control of ablation debris transport in the target chamber and beam tubes. When the neutralized ballistic transport mode is employed, the background gas density should be adequately low and the beam tube metallic surfaces upstream of the neutralizing region should be free of contaminants. TSUNAMI 2.8 was used for the first simulation of gas transport through the complex geometry of the liquid blanket of a hybrid target chamber and beam lines. Concurrently, the feasibility of controlling the gas density was addressed with a novel beam tube design, which introduces magnetic shutters and a long low

  15. Effectiveness of Nitrous Oxide as a Liquid Injection Thrust Vector Control Fluid Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Nitrous Oxide is proposed as an energetic liquid injection thrust vector control fluid for vehicle attitude control during dynamic vehicle maneuvers. Pulled from the...

  16. Stabilising falling liquid film flows using feedback control

    CERN Document Server

    Thompson, Alice B; Pavliotis, Grigorios A; Papageorgiou, Demetrios T

    2015-01-01

    The flow of a fluid layer with one interface exposed to the air and the other an inclined planar wall becomes unstable due to inertial effects when the fluid layer is sufficiently thick or the slope sufficiently steep. This free surface flow of a single fluid layer has industrial applications including coating and heat transfer, which benefit from smooth and wavy interfaces, respectively. Here we discuss how the dynamics of the system are altered by introducing deliberately spatially-varying or time-dependent perturbations via the injection and suction of fluid through the wall. We find that injection and suction is a remarkably effective control mechanism: the controls can be used to drive the system towards arbitrary steady states and travelling waves, and the qualitative effects are independent of the details of the flow modelling. Furthermore, the system can still be successfully controlled even if the feedback must be applied via a set of localised actuators, and only a small number of system observation...

  17. PID Daylight Control System

    Directory of Open Access Journals (Sweden)

    Horaţiu Ştefan Grif

    2011-06-01

    Full Text Available The paper describes the implementation and the tuning of a digital PID controller used in a daylight control application. Due to the fact that the process is unknown, an experimental method, Ziegler-Nichols, for the tuning of the PID controller was used. The obtained PID parameters do not offer a good behavior of the ALCS. To improve the performances of the ALCS, supplementary tuning of the PID parameters, via step response analysis, was made. The step response acquiring and analysis may have an expensive time cost. To avoid the time cost the present paper offers an algorithm which guide the designer to chose, in a slight manner, not only a set but a set family of the PID parameters for which the ALCS has a good behavior. Also, the algorithm presents the way how the ALCS user can set his desired ALCS speed reaction to the daylight variations.

  18. Studies in Three Phase Gas-Liquid Fluidised Systems

    Science.gov (United States)

    Awofisayo, Joyce Ololade

    1992-01-01

    Available from UMI in association with The British Library. The work is a logical continuation of research started at Aston some years ago when studies were conducted on fermentations in bubble columns. The present work highlights typical design and operating problems that could arise in such systems as waste water, chemical, biochemical and petroleum operations involving three-phase, gas-liquid -solid fluidisation; such systems are in increasing use. It is believed that this is one of few studies concerned with "true" three-phase, gas-liquid-solid fluidised systems, and that this work will contribute significantly to closing some of the gaps in knowledge in this area. The research work was experimentally based and involved studies of the hydrodynamic parameters, phase holdups (gas and solid), particle mixing and segregation, and phase flow dynamics (flow regime and circulation patterns). The studies have focused particularly on the solid behaviour and the influence of properties of solids present on the above parameters in three-phase, gas-liquid-solid fluidised systems containing single particle components and those containing binary and ternary mixtures of particles. All particles were near spherical in shape and two particle sizes and total concentration levels were used. Experiments were carried out in two- and three-dimensional bubble columns. Quantitative results are presented in graphical form and are supported by qualitative results from visual studies which are also shown as schematic diagrams and in photographic form. Gas and solid holdup results are compared for air-water containing single, binary and ternary component particle mixtures. It should be noted that the criteria for selection of the materials used are very important if true three-phase fluidisation is to be achieved: this is very evident when comparing the results with those in the literature. The fluid flow and circulation patterns observed were assessed for validation of the generally

  19. Ground Control System Description Document

    Energy Technology Data Exchange (ETDEWEB)

    Eric Loros

    2001-07-31

    The Ground Control System contributes to the safe construction and operation of the subsurface facility, including accesses and waste emplacement drifts, by maintaining the configuration and stability of the openings during construction, development, emplacement, and caretaker modes for the duration of preclosure repository life. The Ground Control System consists of ground support structures installed within the subsurface excavated openings, any reinforcement made to the rock surrounding the opening, and inverts if designed as an integral part of the system. The Ground Control System maintains stability for the range of geologic conditions expected at the repository and for all expected loading conditions, including in situ rock, construction, operation, thermal, and seismic loads. The system maintains the size and geometry of operating envelopes for all openings, including alcoves, accesses, and emplacement drifts. The system provides for the installation and operation of sensors and equipment for any required inspection and monitoring. In addition, the Ground Control System provides protection against rockfall for all subsurface personnel, equipment, and the engineered barrier system, including the waste package during the preclosure period. The Ground Control System uses materials that are sufficiently maintainable and that retain the necessary engineering properties for the anticipated conditions of the preclosure service life. These materials are also compatible with postclosure waste isolation performance requirements of the repository. The Ground Control System interfaces with the Subsurface Facility System for operating envelopes, drift orientation, and excavated opening dimensions, Emplacement Drift System for material compatibility, Monitored Geologic Repository Operations Monitoring and Control System for ground control instrument readings, Waste Emplacement/Retrieval System to support waste emplacement operations, and the Subsurface Excavation System

  20. Evaluation of battery packs for liquid microclimate cooling systems

    Science.gov (United States)

    Teal, Walter B., Jr.; Avellini, Barbara A.

    1995-05-01

    The Navy clothing and Textile Research Facility conducted a literature and industry survey to determine the best commercially available battery technology for use with liquid microclimate cooling systems (MCS), and a laboratory evaluation of a battery pack utilizing that technology. Nickel/cadmium batteries were determined to be the best battery technology commercially available at the present time. However, several other battery technologies are nearing commercialization and may be available in the near future.

  1. Nematic liquid crystals on spherical surfaces: Control of defect configurations by temperature, density, and rod shape

    Science.gov (United States)

    Dhakal, Subas; Solis, Francisco J.; Olvera de la Cruz, Monica

    2012-07-01

    Recent experiments have shown that defect conformations in spherical nematic liquid crystals can be controlled through variations of temperature, shell thickness, and other environmental parameters. These modifications can be understood as a result of the induced changes in the effective elastic constants of the system. To characterize the relation between defect conformations and elastic anisotropy, we carry out Monte Carlo simulations of a nematic on a spherical surface. As the anisotropy is increased, the defects flow from a tetrahedral arrangement to two coalescing pairs and then to a great circle configuration. We also analyze this flow using a variational method based on harmonic configurations.

  2. Communicating Networked Control Systems

    Science.gov (United States)

    2007-03-31

    Bahamas, pages 1010-1015. 64. Carmen Del Vecchio and I.C. Paschalidis, “Supply Contracts with Service Level Requirements”, Proceedings of the IFAC...control using Monte Carlo sensing,” Proc. IEEE International Conference on Robotics and Automation, pp. 3058-3063, 2005. 10. S.B. Andersson, A.A. Handzel, V...Analysis, Madrid Spain. 20. S. Andersson and D. Hristu-Varsakelis, “Language-based feedback control using Monte -Carlo sensing”, to be subm. To IEEE Int’l

  3. Hybrid Systems: Computation and Control.

    Science.gov (United States)

    2007-11-02

    elbow) and a pinned first joint (shoul- der) (see Figure 2); it is termed an underactuated system since it is a mechanical system with fewer...Montreal, PQ, Canada, 1998. [10] M. W. Spong. Partial feedback linearization of underactuated mechanical systems . In Proceedings, IROS󈨢, pages 314-321...control mechanism and search for optimal combinations of control variables. Besides the nonlinear and hybrid nature of powertrain systems , hardware

  4. The CARMA Control System

    Science.gov (United States)

    Gwon, C.; Beard, A. D.; Daniel, P.; Hobbs, R.; Scott, S. L.; Kraybill, J. C.; Leitch, E.; Mehringer, D. M.; Plante, R.; Amarnath, N. S.; Pound, M. W.; Rauch, K. P.; Teuben, P. J.

    2004-07-01

    The Combined Array for Research in Millimeter-wave Astronomy (CARMA) will be the combination of the BIMA, OVRO, and SZA millimeter arrays. With first light scheduled for 2005, CARMA will be the first heterogeneous millimeter array, combining antennas varying from 3.5 m to 10.4 m in diameter. The controls for CARMA involve creating a uniform interface for all antennas. The antennas are grouped into five independently-controlled sub-arrays, which will be used for scientific observations, engineering, or maintenance. The sub-arrays are controlled by two components: the Sub-array Command Processor (SCP) and the Sub-array Tracker (SAT). While each sub-array has a dedicated SCP for handling command processing, a single SAT computes and distributes slowly varying parameters to the necessary sub-arrays. The sub-array interface uses CORBA distributed objects to physically separate the user interface from the array. This allows for stability in the core engine controlling the array while enabling flexibility in the user interface implementation.

  5. Electrochemically controlled supramolecular systems

    NARCIS (Netherlands)

    Nijhuis, Christian A.; Ravoo, Bart Jan; Huskens, Jurriaan; Reinhoudt, David N.

    2007-01-01

    Large and complex molecular structures can be assembled by supramolecular chemistry and self-organization. For practical purposes it is required that the assembly and disassembly of supramolecular complexes and materials can be directed and controlled by external stimuli in order to build, for insta

  6. Approximate controllability of distributed systems by distributed controllers

    Directory of Open Access Journals (Sweden)

    Benzion Shklyar

    2005-04-01

    Full Text Available Approximate controllability problem for a linear distributed control system with possibly unbounded input operator, connected in a series to another distributed system without control is investigated. An initial state of the second distributed system is considered as a control parameter. Applications to control partial equations governed by hyperbolic controller, and to control delay systems governed by hereditary controller are considered.

  7. Using Vibrations to Probe and Control Photoisomerization in Liquids

    Science.gov (United States)

    2014-08-07

    toward the conical intersection. Resonance Raman scattering experiments show that the C=C stretching vibration of the central ethylenic bond has a...Figure 1, that controls the passage of the system towards the conical intersection. Because crossing the barrier takes substantially longer than the...teristic times for motion on the excited- and ground-state surfaces. The excited molecule moves to the conical intersection in about 300 fs and takes

  8. Design and simulation of liquid cooled system for power battery of PHEV

    Science.gov (United States)

    Wang, Jianpeng; Xu, Haijun; Xu, Xiaojun; Pan, Cunyun

    2017-09-01

    Various battery chemistries have different responses to failure, but the most common failure mode of a cell under abusive conditions is the generation of heat and gas. To prevent battery thermal abuse, a battery thermal management system is essential. An excellent design of battery thermal management system can ensure that the battery is working at a suitable temperature and keeps the battery temperature diffenence at 2-3 °C. This paper presents a thermal-elcetric coupling model for a 37Ah lithium battery using AMESim. A liquid cooled system of hybrid electric vehicle power battery is designed to control the battery temperature.A liquid cooled model of thermal management system is built using AMESim, the simulation results showed that the temperature difference within 3°C of cell in the pack.

  9. Arithmetically Controlled H Systems

    Directory of Open Access Journals (Sweden)

    V. Manca

    1998-06-01

    Full Text Available We consider two classes of restricted H systems, both dealing with numbers associated to the terms of splicing operations. In one of them, these numbers indicate the age of the strings (the generation when the strings are produced, in the second one the numbers can be interpreted as valences of the strings. Restricting the splicing to strings of "a similar age", or accepting as complete splicing processes only those processes which produce strings with a null valence increase the generative power of H systems (with finite sets of rules.

  10. 21 CFR 862.2260 - High pressure liquid chromatography system for clinical use.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false High pressure liquid chromatography system for... Clinical Laboratory Instruments § 862.2260 High pressure liquid chromatography system for clinical use. (a) Identification. A high pressure liquid chromatography system for clinical use is a device intended to...

  11. 21 CFR 862.2250 - Gas liquid chromatography system for clinical use.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Gas liquid chromatography system for clinical use... Instruments § 862.2250 Gas liquid chromatography system for clinical use. (a) Identification. A gas liquid chromatography system for clinical use is a device intended to separate one or more drugs or compounds from...

  12. Vapor-liquid equilibria of coal-derived liquids; 3: Binary systems with tetralin at 200 mmHg

    Energy Technology Data Exchange (ETDEWEB)

    Blanco, B.; Beltran, S.; Cabezas, J.L. (University Coll., Burgos (Spain). Dept. of Chemical Engineering); Coca, J. (Univ. of Oviedo (Spain). Dept. of Chemical Engineering)

    1994-01-01

    Isobaric vapor-liquid equilibrium data are reported for binary systems of tetralin with p-xylene, [gamma]-picoline, piperidine, and pyridine; all systems were measured at 26.66 kPa (200 mmHg) with a recirculation still. Liquid-phase activity coefficients were correlated using the Van Laar, Wilson, NRTL, and UNIQUAC equations. Vapor-phase nonidealities were found negligible under the experimental conditions of this work, and deviations of the liquid phase from the ideal behavior, as described by Raoult's law, were found to be slightly positive for all the systems.

  13. Robust power system frequency control

    CERN Document Server

    Bevrani, Hassan

    2008-01-01

    Emphasizes the physical and engineering aspects of the power system frequency control design problem while providing a conceptual understanding of frequency regulation and application of robust control techniques. This book summarizes the author's research outcomes, contributions and experiences with power system frequency regulation.

  14. High Accuracy Liquid Propellant Slosh Predictions Using an Integrated CFD and Controls Analysis Interface

    Science.gov (United States)

    Marsell, Brandon; Griffin, David; Schallhorn, Dr. Paul; Roth, Jacob

    2012-01-01

    Coupling computational fluid dynamics (CFD) with a controls analysis tool elegantly allows for high accuracy predictions of the interaction between sloshing liquid propellants and th e control system of a launch vehicle. Instead of relying on mechanical analogs which are not valid during aU stages of flight, this method allows for a direct link between the vehicle dynamic environments calculated by the solver in the controls analysis tool to the fluid flow equations solved by the CFD code. This paper describes such a coupling methodology, presents the results of a series of test cases, and compares said results against equivalent results from extensively validated tools. The coupling methodology, described herein, has proven to be highly accurate in a variety of different cases.

  15. Integrated CFD and Controls Analysis Interface for High Accuracy Liquid Propellant Slosh Predictions

    Science.gov (United States)

    Marsell, Brandon; Griffin, David; Schallhorn, Paul; Roth, Jacob

    2012-01-01

    Coupling computational fluid dynamics (CFD) with a controls analysis tool elegantly allows for high accuracy predictions of the interaction between sloshing liquid propellants and the control system of a launch vehicle. Instead of relying on mechanical analogs which are n0t va lid during all stages of flight, this method allows for a direct link between the vehicle dynamic environments calculated by the solver in the controls analysis tool to the fluid now equations solved by the CFD code. This paper describes such a coupling methodology, presents the results of a series of test cases, and compares said results against equivalent results from extensively validated tools. The coupling methodology, described herein, has proven to be highly accurate in a variety of different cases.

  16. Liquid-Vapor Equilibrium of Multicomponent Cryogenic Systems

    Science.gov (United States)

    Thompson, W. Reid; Calado, Jorge C. G.; Zollweg, John A.

    1990-01-01

    Liquid-vapor and solid-vapor equilibria at low to moderate pressures and low temperatures are important in many solar system environments, including the surface and clouds of Titan, the clouds of Uranus and Neptune, and the surfaces of Mars and Triton. The familiar cases of ideal behavior are limiting cases of a general thermodynamic representation for the vapor pressure of each component in a homogeneous multicomponent system. The fundamental connections of laboratory measurements to thermodynamic models are through the Gibbs-Duhem relation and the Gibbs-Helmholtz relation. Using laboratory measurements of the total pressure, temperature, and compositions of the liquid and vapor phases at equilibrium, the values of these parameters can be determined. The resulting model for vapor-liquid equilibrium can then conveniently and accurately be used to calculate pressures, compositions, condensation altitudes, and their dependencies on changing climatic conditions. A specific system being investigated is CH4-C2H6-N2, at conditions relevant to Titan's surface and atmosphere. Discussed are: the modeling of existing data on CH4-N2, with applications to the composition of Titan's condensate clouds; some new measurements on the CH4-C2H6 binary, using a high-precision static/volumetric system, and on the C2H6-N2 binary, using the volumetric system and a sensitive cryogenic flow calorimeter; and describe a new cryogenic phase-equilibrium vessel with which we are beginning a detailed, systematic study of the three constituent binaries and the ternary CH4-C2H6-N2 system at temperatures ranging from 80 to 105 K and pressures from 0.1 to 7 bar.

  17. Control Rod Driveline Reactivity Feedback Model for Liquid Metal Reactors

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Young-Min; Jeong, Hae-Yong; Chang, Won-Pyo; Cho, Chung-Ho; Lee, Yong-Bum

    2008-01-15

    The thermal expansion of the control rod drivelines (CRDL) is one important passive mitigator under all unprotected accident conditions in the metal and oxide cores. When the CRDL are washed by hot sodium in the coolant outlet plenum, the CRDL thermally expands and causes the control rods to be inserted further down into the active core region, providing a negative reactivity feedback. Since the control rods are attached to the top of the vessel head and the core attaches to the bottom of the reactor vessel (RV), the expansion of the vessel wall as it heats will either lower the core or raise the control rods supports. This contrary thermal expansion of the reactor vessel wall pulls the control rods out of the core somewhat, providing a positive reactivity feedback. However this is not a safety factor early in a transient because its time constant is relatively large. The total elongated length is calculated by subtracting the vessel expansion from the CRDL expansion to determine the net control rod expansion into the core. The system-wide safety analysis code SSC-K includes the CRDL/RV reactivity feedback model in which control rod and vessel expansions are calculated using single-nod temperatures for the vessel and CRDL masses. The KALIMER design has the upper internal structures (UIS) in which the CRDLs are positioned outside the structure where they are exposed to the mixed sodium temperature exiting the core. A new method to determine the CRDL expansion is suggested. Two dimensional hot pool thermal hydraulic model (HP2D) originally developed for the analysis of the stratification phenomena in the hot pool is utilized for a detailed heat transfer between the CRDL mass and the hot pool coolant. However, the reactor vessel wall temperature is still calculated by a simple lumped model.

  18. Control of nonlinear systems with applications

    Science.gov (United States)

    Pan, Haizhou

    the efficacy of our proposed saturation control design framework. The second part of this research addresses adaptive nonlinear control designs for nonlinear systems, with application to several real-world problems. This research is motivated by the inherent nonlinear characteristics of most physical plants. Although control theory for linear systems is quite mature and has been successful in practice, it is often inadequate when dealing with nonlinear systems. In addition, inaccurately known and often unknown plant parameter/plant and unpredictable environmental changes render the nonlinear control design problems more complicated. In this research, we utilize a Lyapunov framework combined with the backstepping methodology to design adaptive full-state feedback controllers for several interesting real-world problems. First, we consider a liquid level control problem in a state-coupled water tank system. Next, we address the combined orbit and attitude modeling and adaptive control design problems for a 6 degree of freedom (DOF) spacecraft. We also consider a spacecraft formation control problem with combined orbit and attitude dynamics. For each problem, all control designs are validated via experimentation or simulation studies.

  19. Optimal Control of Mechanical Systems

    Directory of Open Access Journals (Sweden)

    Vadim Azhmyakov

    2007-01-01

    Full Text Available In the present work, we consider a class of nonlinear optimal control problems, which can be called “optimal control problems in mechanics.” We deal with control systems whose dynamics can be described by a system of Euler-Lagrange or Hamilton equations. Using the variational structure of the solution of the corresponding boundary-value problems, we reduce the initial optimal control problem to an auxiliary problem of multiobjective programming. This technique makes it possible to apply some consistent numerical approximations of a multiobjective optimization problem to the initial optimal control problem. For solving the auxiliary problem, we propose an implementable numerical algorithm.

  20. VERTICAL FLOW OF GAS-LIQUID-SOLID PARTICLES SYSTEM

    OpenAIRE

    幡手, 泰雄; 野村, 博; 碇, 醇; ハタテ, ヤスオ; ノムラ, ヒロシ; イカリ, アツシ; HATATE, Yasuo; Nomura, Hiroshi; IKARI, Atsushi

    1983-01-01

    It is significant to know the hydrodynamic characteristics of the system in the design and scale-up of reactors containing gas-liquid-solid particles system. As a fundamental study of such a three-phase flow, the gas holdup and the pressure drop were measured in the vertical tubes, through which various mixtures of air, water, and fine glass-sphere, particles were passed. Three kinds of glass particles were used the average sizes of which were 30, 60 and 90 μm. Two kinds of tubes, 15 an...

  1. FFT-LB Modeling of Thermal Liquid-Vapor System

    Institute of Scientific and Technical Information of China (English)

    甘延标; 许爱国; 张广财; 李英骏

    2012-01-01

    We present an improved lattice Boltzmann(LB) model for thermal liquid-vapor system.In the new model,the Windowed Fast Fourier Transform(WFFT) and its inverse are used to calculate both the convection term and the external force term of the LB equation.By adopting the WFFT scheme,Gibbs oscillations can be damped effectively in unsmooth regions while high resolution feature of the spectral method can be retained in smooth regions.As a result,spatial discretization errors are dramatically decreased,conservation of the total energy is much better preserved,and the spurious velocities near the liquid-vapor interface are significantly reduced.The high resolution,together with the low complexity of the WFFT approach,endows the proposed method with considerable potential for studying a wide class of problems in the field of multiphase flows.

  2. Two Beam Energy Exchange in Hybrid Liquid Crystal Cells with Photorefractive Field Controlled Boundary Conditions (Postprint)

    Science.gov (United States)

    2016-09-12

    AFRL-RX-WP-JA-2017-0209 TWO BEAM ENERGY EXCHANGE IN HYBRID LIQUID CRYSTAL CELLS WITH PHOTOREFRACTIVE FIELD CONTROLLED BOUNDARY...DATES COVERED (From - To) 29 August 2016 Interim 26 October 2015 – 29 July 2016 4. TITLE AND SUBTITLE TWO BEAM ENERGY EXCHANGE IN HYBRID LIQUID... energy gain when two light beams intersect in a hybrid nematic liquid crystal (LC) cell with photorefractive crystalline substrates. A periodic space

  3. Control principles of complex systems

    Science.gov (United States)

    Liu, Yang-Yu; Barabási, Albert-László

    2016-07-01

    A reflection of our ultimate understanding of a complex system is our ability to control its behavior. Typically, control has multiple prerequisites: it requires an accurate map of the network that governs the interactions between the system's components, a quantitative description of the dynamical laws that govern the temporal behavior of each component, and an ability to influence the state and temporal behavior of a selected subset of the components. With deep roots in dynamical systems and control theory, notions of control and controllability have taken a new life recently in the study of complex networks, inspiring several fundamental questions: What are the control principles of complex systems? How do networks organize themselves to balance control with functionality? To address these questions here recent advances on the controllability and the control of complex networks are reviewed, exploring the intricate interplay between the network topology and dynamical laws. The pertinent mathematical results are matched with empirical findings and applications. Uncovering the control principles of complex systems can help us explore and ultimately understand the fundamental laws that govern their behavior.

  4. Microprocessor control of photovoltaic systems

    Science.gov (United States)

    Millner, A. R.; Kaufman, D. L.

    1984-01-01

    The present low power CMOS microprocessor controller for photovoltaic power systems possesses three programs, which are respectively intended for (1) conventional battery-charging systems with state-of-charge estimation and sequential shedding of subarrays and loads, (2) maximum power-controlled battery-charging systems, and (3) variable speed dc motor drives. Attention is presently given to the development of this terrestrial equipment for spacecraft use.

  5. Uzaybimer Radio Telescope Control System

    Science.gov (United States)

    Balbay, R.; Öz, G. K.; Arslan, Ö.; Özeren, F. F.; Küçük, İ.

    2016-12-01

    A 13 meters former NATO radar is being converted into a radio telescope. The radio telescope is controlled by a system which has been developed at UZAYBİMER. The Telescope Control System(TCS) has been designed using modern industrial systems. TCS has been developed in LabView platform in which works Windows embedded OS. The position feedback used on radio telescopes is an industrial EtherCAT standard. ASCOM library is used for astronomical calculations.

  6. Aircraft control system

    Science.gov (United States)

    Lisoski, Derek L. (Inventor); Kendall, Greg T. (Inventor)

    2007-01-01

    A solar rechargeable, long-duration, span-loaded flying wing, having no fuselage or rudder. Having a two-hundred foot wingspan that mounts photovoltaic cells on most all of the wing's top surface, the aircraft uses only differential thrust of its eight propellers to turn, pitch and yaw. The wing is configured to deform under flight loads to position the propellers such that the control can be achieved. Each of five segments of the wing has one or more motors and photovoltaic arrays, and produces its own lift independent of the other segments, to avoid loading them. Five two-sided photovoltaic arrays, in all, are mounted on the wing, and receive photovoltaic energy both incident on top of the wing, and which is incident also from below, through a bottom, transparent surface.

  7. Distributed Health Monitoring System for Reusable Liquid Rocket Engines

    Science.gov (United States)

    Lin, C. F.; Figueroa, F.; Politopoulos, T.; Oonk, S.

    2009-01-01

    The ability to correctly detect and identify any possible failure in the systems, subsystems, or sensors within a reusable liquid rocket engine is a major goal at NASA John C. Stennis Space Center (SSC). A health management (HM) system is required to provide an on-ground operation crew with an integrated awareness of the condition of every element of interest by determining anomalies, examining their causes, and making predictive statements. However, the complexity associated with relevant systems, and the large amount of data typically necessary for proper interpretation and analysis, presents difficulties in implementing complete failure detection, identification, and prognostics (FDI&P). As such, this paper presents a Distributed Health Monitoring System for Reusable Liquid Rocket Engines as a solution to these problems through the use of highly intelligent algorithms for real-time FDI&P, and efficient and embedded processing at multiple levels. The end result is the ability to successfully incorporate a comprehensive HM platform despite the complexity of the systems under consideration.

  8. Numerical and experimental investigation of a confined plunging liquid jet system

    OpenAIRE

    Mishra, A

    2012-01-01

    In a confined plunging liquid jet (CPLJ) system, a liquid jet is allowed to fall in a partially submerged narrow downcomer tube. Liquid jet impingement at gas-liquid interface leads to entrainment of gas, which is dispersed down the downcomer tube in to outer pool in form of bubbles. This simple phenomenon of gas entrainment bears great industrial significance. It facilitates an efficient gas liquid contacting device, which can be used for waste water aeration and lake destratification etc. I...

  9. Quantitative Determination on Ionic-Liquid-Gating Control of Interfacial Magnetism.

    Science.gov (United States)

    Zhao, Shishun; Zhou, Ziyao; Peng, Bin; Zhu, Mingmin; Feng, Mengmeng; Yang, Qu; Yan, Yuan; Ren, Wei; Ye, Zuo-Guang; Liu, Yaohua; Liu, Ming

    2017-03-03

    Ionic-liquid gating on a functional thin film with a low voltage has drawn a lot of attention due to rich chemical, electronic, and magnetic phenomena at the interface. Here, a key challenge in quantitative determination of voltage-controlled magnetic anisotropy (VCMA) in Au/[DEME](+) [TFSI](-) /Co field-effect transistor heterostructures is addressed. The magnetic anisotropy change as response to the gating voltage is precisely detected by in situ electron spin resonance measurements. A reversible change of magnetic anisotropy up to 219 Oe is achieved with a low gating voltage of 1.5 V at room temperature, corresponding to a record high VCMA coefficient of ≈146 Oe V(-1) . Two gating effects, the electrostatic doping and electrochemical reaction, are distinguished at various gating voltage regions, as confirmed by X-ray photoelectron spectroscopy and atomic force microscopy experiments. This work shows a unique ionic-liquid-gating system for strong interfacial magnetoelectric coupling with many practical advantages, paving the way toward ion-liquid-gating spintronic/electronic devices.

  10. Controllable parabolic lensed liquid-core optical fiber by using electrostatic force.

    Science.gov (United States)

    Tang, Chun Yin; Zhang, Xuming; Chai, Yang; Hui, Long; Tao, Lili; Tsang, Yuen H

    2014-08-25

    For typical optical fiber system, an external lens accessory set is required to adjust the optical path of output light, which however is limited by the fixed parameter of the lens accessory setup. Considering spherical aberration in the imaging process and its small focusable spot size, a complicated lens combination is required to compensate the aberration. This paper has demonstrated a unique method to fabricate liquid-core lensed fibers by filling water and NOA61 respectively into hollow Teflon AF fibers and silicate fiber, the radius of curvature of the liquid lens can be controlled by adjusting the applied voltage on the core liquid and even parabolic shape lens can be produced with enough applied voltage. The experiment has successfully demonstrated a variation of focal length from 0.628 mm to 0.111 mm responding to the change of applied voltage from 0V to 3.2KV (L = 2mm) for the Teflon AF fiber, as well as a variation of focal length from 0.274 mm to 0.08 mm responding to the change of applied voltage from 0V to 3KV (L = 2mm) for the silicate fiber. Further simulation shows that the focused spot size can be reduced to 2 µm by adjusting the refractive index and fiber geometry. Solid state parabolic lensed fiber can be produced after NOA61 is solidified by the UV curing.

  11. Distributed Stepping Motor Control System

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The beam diagnostic devices used at RIBLL are driven by stepper motors, which are controlled by I/O modules based on ISA-bus in an industrial computer. The disadvantages of such mode are that a large number of long cables are used and one computer to control is unsafe. We have developed a distributed stepping motor control system for the remote, local and centralized control of the stepping motors. RS-485 bus is used for the connection between the remote control unit and the local control units. The con...

  12. Analysis of Liquid Zone Control Valve Oscillation Problem in CANDU Reactors

    OpenAIRE

    Elnara Nasimi; Hossam A. Gabbar

    2013-01-01

    This paper looks at the existing challenges with steady-state Liquid Zone control at some CANDU (CANada Deuterium Uranium) stations, where—contrary to expectations for equilibrium flow—Liquid Zone Control Valve oscillations have proven to be a chronic, unanticipated challenge. Currently, the exact causes of this behaviour are not fully understood, although it is confirmed that the Control Valve oscillations are not due to automatic power adjustment requests or zone level changes due to proces...

  13. Design and evaluation of automatic control for human/liquid cooling garment thermal interaction

    Science.gov (United States)

    Nyberg, Karen Lujean

    An automatic control system was designed and developed to control the thermal comfort of an astronaut wearing a liquid cooling garment (LCG). Experimental trials were run with test subjects performing arm cranking exercise in an environmental chamber. The thermal control algorithm incorporates the use of carbon dioxide production as a measure of metabolic rate to initiate the control response and mean body temperature, as a function of ear canal and skin temperatures, to provide feedback of the human thermal state to the controller. Nine test subjects each completed three, ninety-minute tests in three different environmental temperatures. Subjective comfort levels were obtained from the subjects throughout each test. Evaluation of subjective comfort level and quantitative energy storage indicates good performance of the controller in maintaining thermal neutrality for the subject over a wide range of environmental and transient metabolic states. The Wissler human thermoregulation model was utilized in the control design process and was used to further analyze the experimental results following testing. Subsequent application of the model allowed evaluation of additional protocols for which the LCG thermal controller may be used in the future.

  14. Emission control system

    Science.gov (United States)

    Parrish, Clyde F. (Inventor); Chung, J. Landy (Inventor)

    2009-01-01

    Methods and apparatus utilizing hydrogen peroxide are useful to reduce SOx and mercury (or other heavy metal) emissions from combustion flue gas streams. The methods and apparatus may further be modified to reduce NOx emissions. Continuous concentration of hydrogen peroxide to levels approaching or exceeding propellant-grade hydrogen peroxide facilitates increased system efficiency. In this manner, combustion flue gas streams can be treated for the removal of SOx and heavy metals, while isolating useful by-products streams of sulfuric acid as well as solids for the recovery of the heavy metals. Where removal of NOx emissions is included, nitric acid may also be isolated for use in fertilizer or other industrial applications.

  15. Calculation of liquid-vapor and liquid-liquid equilibrium in multicomponent systems using correlations of equilibrium data

    OpenAIRE

    Reyes Labarta, Juan Antonio; Olaya López, María del Mar; Gómez Siurana, Amparo; Marcilla Gomis, Antonio

    1999-01-01

    Póster presentado en el congreso EQUIFASE 99 (Vigo, del 20 al 24 de Junio de 1999). Resumen publicado en el libro de actas del Congreso An algebraic correlation method to calculate equilibrium data for ternary vapor-liquid equilibrium and quaternary liquid-liquid equilibrium has been proposed. The proposed method allows the calculation of the conjugated phase in equilibrium with a given phase, and the calculation of the two phases in equilibrium from the composition of a heterogeneous glob...

  16. Control of Solar Energy Systems

    CERN Document Server

    Camacho, Eduardo F; Rubio, Francisco R; Martínez, Diego

    2012-01-01

    Control of Solar Energy Systems details the main solar energy systems, problems involved with their control, and how control systems can help in increasing their efficiency.  After a brief introduction to the fundamental concepts associated with the use of solar energy in both photovoltaic and thermal plants, specific issues related to control of solar systems are embarked upon. Thermal energy systems are then explored in depth, as well as  other solar energy applications such as solar furnaces and solar refrigeration systems. Problems of variable generation profile and of the contribution of many solar plants to the same grid system are considered with the necessary integrated and supervisory control solutions being discussed. The text includes material on: ·         A comparison of basic and advanced control methods for parabolic troughs from PID to nonlinear model-based control; ·         solar towers and solar tracking; ·         heliostat calibration, characterization and off...

  17. Control Evaluation Information System Savings

    Directory of Open Access Journals (Sweden)

    Eddy Sutedjo

    2011-05-01

    Full Text Available The purpose of this research is to evaluate the control of information system savings in the banking and to identify the weaknesses and problem happened in those saving systems. Research method used are book studies by collecting data and information needed and field studies by interview, observation, questioner, and checklist using COBIT method as a standard to assess the information system control of the company. The expected result about the evaluation result that show in the problem happened and recommendation given as the evaluation report and to give a view about the control done by the company. Conclusion took from this research that this banking company has met standards although some weaknesses still exists in the system.Index Terms - Control Information System, Savings

  18. Study on Osmotic Pressure and Liquid-Liquid Equilibria for Micelle, Colloid and Microemulsion Systems by Yukawa Potential

    Institute of Scientific and Technical Information of China (English)

    FU,Dong(付东); LU,Jiu-Fang(陆九芳); WU,Wei(吴畏); Li,Yi-Gui(李以圭)

    2004-01-01

    An equation of state (EOS) was established to study the osmotic pressure and liquid-liquid equilibria for micelle,colloid and microemulsion systems. The Carnahan-Starling equation was used for the hard sphere repulsion. The Yukawa potential was used to describe both the attractive dispersion and the double-layer repulsion. By using the established EOS, the osmotic pressures for charged colloid, uncharged micelle, uncharged and weakly charged microemuslion, the phase equilibria for uncharged micelle and charged colloid systems were studied.

  19. Acuity systems and control charting.

    Science.gov (United States)

    Shaha, S H

    1995-01-01

    The strengths of control charting and other statistical process control (SPC) tools have not previously been applied to acuity systems. Intermountain Health Care, Salt Lake City, Utah, developed a new acuity system that relies heavily upon control charting for an array of purposes, including immediate feedback to caregivers regarding decisions, ongoing feedback to managers regarding decision patterns, and longer-term feedback regarding trends and budget-relevant information. The use of control charts has eliminated the need for auditing acuity-based staffing and has maintained the reliability of classifications at levels above 95 percent. Implications for other novel applications are offered.

  20. Commutated automatic gain control system

    Science.gov (United States)

    Yost, S. R.

    1982-01-01

    The commutated automatic gain control (AGC) system was designed and built for the prototype Loran-C receiver is discussed. The current version of the prototype receiver, the Mini L-80, was tested initially in 1980. The receiver uses a super jolt microcomputer to control a memory aided phase loop (MAPLL). The microcomputer also controls the input/output, latitude/longitude conversion, and the recently added AGC system. The AGC control adjusts the level of each station signal, such that the early portion of each envelope rise is about at the same amplitude in the receiver envelope detector.

  1. Traction Control System for Motorcycles

    Directory of Open Access Journals (Sweden)

    Cardinale Pascal

    2009-01-01

    Full Text Available Traction control is a widely used control system to increase stability and safety of four wheel vehicles. Automatic stability control is used in the BMW K1200R motorcycle and in motoGP competition, but not in other motorcycles. This paper presents an algorithm and a low-cost real-time hardware implementation for motorcycles. A prototype has been developed, applied on a commercial motorcycle, and tested in a real track. The control system that can be tuned by the driver during the race has been appreciated by the test driver.

  2. Traction Control System for Motorcycles

    Directory of Open Access Journals (Sweden)

    Massimo Conti

    2009-01-01

    Full Text Available Traction control is a widely used control system to increase stability and safety of four wheel vehicles. Automatic stability control is used in the BMW K1200R motorcycle and in motoGP competition, but not in other motorcycles. This paper presents an algorithm and a low-cost real-time hardware implementation for motorcycles. A prototype has been developed, applied on a commercial motorcycle, and tested in a real track. The control system that can be tuned by the driver during the race has been appreciated by the test driver.

  3. Nonlinear system identification and control based on modular neural networks.

    Science.gov (United States)

    Puscasu, Gheorghe; Codres, Bogdan

    2011-08-01

    A new approach for nonlinear system identification and control based on modular neural networks (MNN) is proposed in this paper. The computational complexity of neural identification can be greatly reduced if the whole system is decomposed into several subsystems. This is obtained using a partitioning algorithm. Each local nonlinear model is associated with a nonlinear controller. These are also implemented by neural networks. The switching between the neural controllers is done by a dynamical switcher, also implemented by neural networks, that tracks the different operating points. The proposed multiple modelling and control strategy has been successfully tested on simulated laboratory scale liquid-level system.

  4. A universal heliostat control system

    Science.gov (United States)

    Gross, Fabian; Geiger, Mark; Buck, Reiner

    2017-06-01

    This paper describes the development of a universal heliostat control system as part of the AutoR project [1]. The system can control multiple receivers and heliostat types in a single application. The system offers support for multiple operators on different machines and is designed to be as adaptive as possible. Thus, the system can be used for different heliostat field setups with only minor adaptations of the system's source code. This is achieved by extensive usage of modern programming techniques like reflection and dependency injection. Furthermore, the system features co-simulation of a ray tracer, a reference PID-controller implementation for open volumetric receivers and methods for heliostat calibration and monitoring.

  5. Linux in Industrial Control Systems

    CERN Document Server

    Riesco, T

    2001-01-01

    Today the Linux operating system has become a real alternative for industrial control systems. Linux supports all layers in control systems starting with Real-Time or embedded systems for data acquisition, following with treatment, storage, communication and data adaptation, and finally, with supervision and user interfaces. In the last years the Linux development has grown being incorporated in several industrial systems demonstrating high performance, availability and stability for complex processes in chemical, automobile or petrol industries. In many of these industries Linux architectures have been tested and validated successfully. The new CERN policy supporting Linux, as well as the emergence of cheap and robust Linux solutions, motivates its implementation in our safety control and supervision systems in the near future.

  6. Liquid crystal multi-mode lenses and axicons based on electronic phase shift control.

    Science.gov (United States)

    Kirby, Andrew K; Hands, Philip J; Love, Gordon D

    2007-10-17

    We report on the principle of operation, construction and testing of a liquid crystal lens which is controlled by distributing voltages across the control electrodes, which are in turn controlled by adjusting the phase of the applied voltages. As well as (positive and negative) defocus, then lenses can be used to control tip/tilt, astigmatism, and to create variable axicons.

  7. MULTIPLE ECH LAUNCHER CONTROL SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    GREEN,M.T; PONCE,D; GRUNLOH,H.J; ELLIS,R.A; GROSNICKLE,W.H; HUMPHREY,R.L

    2003-10-01

    OAK-B135 The addition of new, high power gyrotrons to the heating and current drive arsenal at DIII-D, required a system upgrade for control of fully steerable ECH Launchers. Each launcher contains two pointing mirrors with two degrees of mechanical freedom. The two flavors of motion are called facet and tilt. Therefore up to four channels of motion per launcher need to be controlled. The system utilizes absolute encoders to indicate mirror position and therefore direction of the microwave beam. The launcher movement is primarily controlled by PLC, but future iterations of design, may require this control to be accomplished by a CPU on fast bus such as Compact PCI. This will be necessary to accomplish real time position control. Safety of equipment and personnel is of primary importance when controlling a system of moving parts. Therefore multiple interlocks and fault status enunciators have been implemented. This paper addresses the design of a Multiple ECH Launcher Control System, and characterizes the flexibility needed to upgrade to a real time position control system in the future.

  8. Comparison of automatic control systems

    Science.gov (United States)

    Oppelt, W

    1941-01-01

    This report deals with a reciprocal comparison of an automatic pressure control, an automatic rpm control, an automatic temperature control, and an automatic directional control. It shows the difference between the "faultproof" regulator and the actual regulator which is subject to faults, and develops this difference as far as possible in a parallel manner with regard to the control systems under consideration. Such as analysis affords, particularly in its extension to the faults of the actual regulator, a deep insight into the mechanism of the regulator process.

  9. Facile synthesis and properties of CdSe quantum dots in a novel two-phase liquid/liquid system

    Science.gov (United States)

    Wang, Jidong; Wang, Xiaoyu; Tang, Hengshan; Gao, Zehua; He, Shengquan; Ke, Dandan; Zheng, Yue; Han, Shumin

    2017-10-01

    High-quantity CdSe QDs were synthesized in a novel two-phase liquid/liquid system. This system, ODE/water was stable and as-used solvents were almost nontoxic. The methodology leading to the successful synthesis of CdSe QDs was a typical, one-pot approach and the obtained CdSe QDs with zinc-blende phase structure exhibited excellent optical properties, narrow size distribution, higher particle uniformity and crystallinity. The mechanism of nucleation and growth of CdSe QDs were discussed by the possible thermodynamic equilibrium existing in ODE/water interface. This two-phase liquid/liquid system would broaden the synthesis of other semiconductor QDs.

  10. VA National Bed Control System

    Data.gov (United States)

    Department of Veterans Affairs — The VA National Bed Control System records the levels of operating, unavailable and authorized beds at each VAMC, and it tracks requests for changes in these levels....

  11. Fuel sensor-less control of a liquid feed fuel cell under dynamic loading conditions for portable power sources (II)

    Energy Technology Data Exchange (ETDEWEB)

    Chang, C.L.; Chen, C.Y.; Liou, D.H.; Chang, C.Y.; Cha, H.C. [Institute of Nuclear Energy Research (INER), No. 1000, Wunhua Rd., Jiaan Village, Longtan Township, Taoyuan County 32546 (China); Sung, C.C. [National Taiwan University (China)

    2010-03-01

    This work presents a new fuel sensor-less control scheme for liquid feed fuel cells that is able to control the supply to a fuel cell system for operation under dynamic loading conditions. The control scheme uses cell-operating characteristics, such as potential, current, and power, to regulate the fuel concentration of a liquid feed fuel cell without the need for a fuel concentration sensor. A current integral technique has been developed to calculate the quantity of fuel required at each monitoring cycle, which can be combined with the concentration regulating process to control the fuel supply for stable operation. As verified by systematic experiments, this scheme can effectively control the fuel supply of a liquid feed fuel cell with reduced response time, even under conditions where the membrane electrolyte assembly (MEA) deteriorates gradually. This advance will aid the commercialization of liquid feed fuel cells and make them more adaptable for use in portable and automotive power units such as laptops, e-bikes, and handicap cars. (author)

  12. Control of density fluctuations in atomistic-continuum simulations of dense liquids

    Science.gov (United States)

    Kotsalis, E. M.; Walther, J. H.; Koumoutsakos, P.

    2007-07-01

    We present a control algorithm to eliminate spurious density fluctuations associated with the coupling of atomistic and continuum descriptions for dense liquids. A Schwartz domain decomposition algorithm is employed to couple molecular dynamics for the simulation of the atomistic system with a continuum solver for the simulation of the Navier-Stokes equations. The lack of periodic boundary conditions in the molecular dynamics simulations hinders the proper accounting for the virial pressure leading to spurious density fluctuations at the continuum-atomistic interface. An ad hoc boundary force is usually employed to remedy this situation. We propose the calculation of this boundary force using a control algorithm that explicitly cancels the density fluctuations. The results demonstrate that the present approach outperforms state-of-the-art algorithms. The conceptual and algorithmic simplicity of the method makes it suitable for any type of coupling between atomistic and continuum descriptions of dense fluids.

  13. Optimal Design of Liquid Dampers for Structural Vibration Control Based on GA and H∞ Norm

    Directory of Open Access Journals (Sweden)

    Linsheng Huo

    2013-01-01

    Full Text Available This paper focused on the optimal design of liquid dampers for the seismic response control of structures. The H∞ norm of the transfer function from the ground motion to the structural response is selected as the optimal objective. The optimization procedure is carried out by using Genetic Algorithms (GAs in order to reach an optimal solution. The proposed method has the advantages that it is unnecessary to solve the equation of motion for the control system and that the obtained optimal parameters of dampers are not dependent on the ground motion records. The influences of weighted functions on the optimization results are analyzed. The generality and effeteness of the proposed method are verified by the time history analysis of a 3-story structure subjected to earthquake records in different sites. The results show that the structural responses can be effectively reduced subjected to earthquake excitation at different sites.

  14. Controlling Nonspecific Protein Adsorption in a Plug-Based Microfluidic System by Controlling Interfacial Chemistry Using Fluorous-Phase Surfactants

    OpenAIRE

    Roach, L. Spencer; Song, Helen; Ismagilov, Rustem F.

    2005-01-01

    Control of surface chemistry and protein adsorption is important for using microfluidic devices for biochemical analysis and high-throughput screening assays. This paper describes the control of protein adsorption at the liquid-liquid interface in a plug-based microfluidic system. The microfluidic system uses multiphase flows of immiscible fluorous and aqueous fluids to form plugs, which are aqueous droplets that are completely surrounded by fluorocarbon oil and do not come into direct contac...

  15. Synthesis of pneumatic controll systems

    Directory of Open Access Journals (Sweden)

    D. Nowak

    2011-04-01

    Full Text Available Currently, the basic tool for automating the production processes are the PLCs. However, in many areas application of the pneumaticcontrol systems may be more reasonable. The main factor determining choice of the control technology are costs. In the case of pneumaticsystems, the costs shall be determined by the number of elements used. Therefore, during the design works it is important to choose anappropriate method for the pneumatic control systems synthesis. The article presents the MTS method, which may be used for a discretetechnological processes modeling and PLC programming, as well as for a pneumatic control systems designing. An important element ofthe MTS method is the network of actions, which graphically presents an algorithm of the implemented process. Based on the actionnetwork and operating machine’s functional diagram, the diagram of different states is determinated, which graphically shows changes ofthe control system’s input and output signals. Analysis of the diagram of different states, makes it easy to determine a schematic equation, which shall be the basis for the control system implementation. Advantage of the MTS method is the lack of restrictions on the number of the control system’s input and output signals. The resulting solution is characterized by a minimum number of elements needed to implement the control system.

  16. Reliability and Maintainability Data for Liquid Metal Cooling Systems

    Energy Technology Data Exchange (ETDEWEB)

    Cadwallader, Lee Charles [Idaho National Laboratory

    2015-05-01

    One of the coolants of interest for future fusion breeding blankets is lead-lithium. As a liquid metal it offers the advantages of high temperature operation for good station efficiency, low pressure, and moderate flow rate. This coolant is also under examination for use in test blanket modules to be used in the ITER international project. To perform reliability, availability, maintainability and inspectability (RAMI) assessment as well as probabilistic safety assessment (PSA) of lead-lithium cooling systems, component failure rate data are needed to quantify the system models. RAMI assessment also requires repair time data and inspection time data. This paper presents a new survey of the data sets that are available at present to support RAMI and PSA quantification. Recommendations are given for the best data values to use when quantifying system models.

  17. Contamination Control: a systems approach

    NARCIS (Netherlands)

    Donck, J.C.J. van der

    2010-01-01

    Contamination influences a wide variety of industrial processes. For complex systems, contamination control, the collective effort to control contamination to such a level that it guarantees or even improves process or product functionality, offers a way for finding workable solutions. Central in

  18. Contamination Control: a systems approach

    NARCIS (Netherlands)

    Donck, J.C.J. van der

    2010-01-01

    Contamination influences a wide variety of industrial processes. For complex systems, contamination control, the collective effort to control contamination to such a level that it guarantees or even improves process or product functionality, offers a way for finding workable solutions. Central in th

  19. Contamination Control: a systems approach

    NARCIS (Netherlands)

    Donck, J.C.J. van der

    2010-01-01

    Contamination influences a wide variety of industrial processes. For complex systems, contamination control, the collective effort to control contamination to such a level that it guarantees or even improves process or product functionality, offers a way for finding workable solutions. Central in th

  20. Robust power system frequency control

    CERN Document Server

    Bevrani, Hassan

    2014-01-01

    This updated edition of the industry standard reference on power system frequency control provides practical, systematic and flexible algorithms for regulating load frequency, offering new solutions to the technical challenges introduced by the escalating role of distributed generation and renewable energy sources in smart electric grids. The author emphasizes the physical constraints and practical engineering issues related to frequency in a deregulated environment, while fostering a conceptual understanding of frequency regulation and robust control techniques. The resulting control strategi

  1. Pump control system for windmills

    Science.gov (United States)

    Avery, Don E.

    1983-01-01

    A windmill control system having lever means, for varying length of stroke of the pump piston, and a control means, responsive to the velocity of the wind to operate the lever means to vary the length of stroke and hence the effective displacement of the pump in accordance with available wind energy, with the control means having a sensing member separate from the windmill disposed in the wind and displaceable thereby in accordance with wind velocity.

  2. A novel microsatellite control system

    Energy Technology Data Exchange (ETDEWEB)

    Moore, K.R.; Frigo, J.R.; Tilden, M.W.

    1998-02-01

    The authors are researching extremely simple yet quite capable analog pulse-coded neural networks for ``smaller-faster-cheaper`` spacecraft attitude and control systems. The will demonstrate a prototype microsatellite that uses their novel control method to autonomously stabilize itself in the ambient magnetic field and point itself at the brightest available light source. Though still in design infancy, the ``Nervous Net`` controllers described could allow for space missions not currently possible given conventional satellite hardware. Result, prospects and details are presented.

  3. The ATLAS Detector Control System

    CERN Document Server

    Schlenker, S; Kersten, S; Hirschbuehl, D; Braun, H; Poblaguev, A; Oliveira Damazio, D; Talyshev, A; Zimmermann, S; Franz, S; Gutzwiller, O; Hartert, J; Mindur, B; Tsarouchas, CA; Caforio, D; Sbarra, C; Olszowska, J; Hajduk, Z; Banas, E; Wynne, B; Robichaud-Veronneau, A; Nemecek, S; Thompson, PD; Mandic, I; Deliyergiyev, M; Polini, A; Kovalenko, S; Khomutnikov, V; Filimonov, V; Bindi, M; Stanecka, E; Martin, T; Lantzsch, K; Hoffmann, D; Huber, J; Mountricha, E; Santos, HF; Ribeiro, G; Barillari, T; Habring, J; Arabidze, G; Boterenbrood, H; Hart, R; Marques Vinagre, F; Lafarguette, P; Tartarelli, GF; Nagai, K; D'Auria, S; Chekulaev, S; Phillips, P; Ertel, E; Brenner, R; Leontsinis, S; Mitrevski, J; Grassi, V; Karakostas, K; Iakovidis, G.; Marchese, F; Aielli, G

    2011-01-01

    The ATLAS experiment is one of the multi-purpose experiments at the Large Hadron Collider (LHC), constructed to study elementary particle interactions in collisions of high-energy proton beams. Twelve different sub-detectors as well as the common experimental infrastructure are supervised by the Detector Control System (DCS). The DCS enables equipment supervision of all ATLAS sub-detectors by using a system of >130 server machines running the industrial SCADA product PVSS. This highly distributed system reads, processes and archives of the order of 106 operational parameters. Higher level control system layers allow for automatic control procedures, efficient error recognition and handling, and manage the communication with external systems such as the LHC. This contribution firstly describes the status of the ATLAS DCS and the experience gained during the LHC commissioning and the first physics data taking operation period. Secondly, the future evolution and maintenance constraints for the coming years an...

  4. Trace Material Capture by Controlled Liquid Droplets on a Superhydrophobic/Hydrophilic Surface.

    Science.gov (United States)

    Fukada, Kenta; Kawamura, Naoya; Shiratori, Seimei

    2017-09-15

    A liquid droplet in contact with a superhydrophobic surface can be used to collect dissolved trace materials after evaporating the solvent. This process effect enhances detection limits, but a liquid droplet easily rolls off a superhydrophobic surface. Keeping it at a specific collecting spot area is challenging. Here the means for controlling and capturing a liquid droplet on a superhydrophobic surface is demonstrated. To induce a liquid droplet to a collecting spot, its rolling direction was controlled by two superhydrophobic fabric guides. The liquid droplet was then captured by hydrophilic polymer and hydrophilic nanoparticles at the measuring spot. After removing the solvent, the trace compounds were evaluated with a colorimetric analysis visible to the naked eye.

  5. IMPULSE CONTROL HYBRID ELECTRICAL SYSTEM

    Directory of Open Access Journals (Sweden)

    A. A. Lobaty

    2016-01-01

    Full Text Available This paper extends the recently introduced approach for modeling and solving the optimal control problem of fixedswitched mode DC-DC power converter. DCDC converters are a class of electric power circuits that used extensively in regulated DC power supplies, DC motor drives of different types, in Photovoltaic Station energy conversion and other applications due to its advantageous features in terms of size, weight and reliable performance. The main problem in controlling this type converters is in their hybrid nature as the switched circuit topology entails different modes of operation, each of it with its own associated linear continuous-time dynamics.This paper analyses the modeling and controller synthesis of the fixed-frequency buck DC-DC converter, in which the transistor switch is operated by a pulse sequence with constant frequency. In this case the regulation of the DC component of the output voltage is via the duty cycle. The optimization of the control system is based on the formation of the control signal at the output.It is proposed to solve the problem of optimal control of a hybrid system based on the formation of the control signal at the output of the controller, which minimizes a given functional integral quality, which is regarded as a linear quadratic Letov-Kalman functional. Search method of optimal control depends on the type of mathematical model of control object. In this case, we consider a linear deterministic model of the control system, which is common for the majority of hybrid electrical systems. For this formulation of the optimal control problem of search is a problem of analytical design of optimal controller, which has the analytical solution.As an example of the hybrid system is considered a step-down switching DC-DC converter, which is widely used in various electrical systems: as an uninterruptible power supply, battery charger for electric vehicles, the inverter in solar photovoltaic power plants.. A

  6. Development of systems for the laser synthesis of nanoparticles starting from liquid precursors

    Science.gov (United States)

    Popovici, E.; Luculescu, C.; Alexandrescu, R.; Fleaca, C.; Dumitrache, F.; Barjega, R.; Scarisoreanu, M.; Dutu, E.; Barbut, A.; Morjan, I.; Vasile, E.

    2012-09-01

    The laser synthesis of nanoparticles starting from liquid precursors is particularly suitable as synthesis technique for obtaining nanoparticles. In the present work the laser pyrolysis is performed in a novel setup where the liquid precursor is brought with the aid of an original evaporator system to temperatures in excess of the boiling point and is finally fed into the reactor under the form of heated vapors.The process occurs in the gas phase and ensures the avoidance of the condensation. The temperature control system allows for the maintaining of the overall system temperature below the decomposition temperature and above the boiling. Temperatures up to 500 °C are assured for the mixed precursors. The control of the amount of the active substances is performed upstream, in the liquid phase. The set-up is able to offer safety conditions at the synthesis of substances with high toxicity. This experimental set-up was proposed in order to synthesize TiO2 nanoparticles from TTIP because its boiling temperature is relatively high (239 °C grades). Different analytical techniques such as EDX, TEM, XRD and HRTEM were used in order to evaluate the structural characteristics of the produced nanopowders.

  7. Liquid-Metal Microdroplets Formed Dynamically with Electrical Control of Size and Rate.

    Science.gov (United States)

    Tang, Shi-Yang; Joshipura, Ishan D; Lin, Yiliang; Kalantar-Zadeh, Kourosh; Mitchell, Arnan; Khoshmanesh, Khashayar; Dickey, Michael D

    2016-01-27

    Liquid metal co-injected with electrolyte through a microfluidic flow-focusing orifice forms droplets with diameters and production frequencies controlled in real time by voltage. Applying voltage to the liquid metal controls the interfacial tension via a combination of electrochemistry and electrocapillarity. This simple and effective method can instantaneously tune the size of the microdroplets, which has applications in composites, catalysts, and microsystems.

  8. Study of Baffle Boundary and System Parameters on Liquid-Solid Coupling Vibration of Rectangular Liquid-Storage Structure

    Directory of Open Access Journals (Sweden)

    Wei Jing

    2016-01-01

    Full Text Available In order to study the vibration problem of liquid-solid coupling of rectangular liquid-storage structure with horizontal elastic baffle, ignoring the influence of surface gravity wave, two different velocity potential functions corresponding to the liquid above and below the elastic baffle are assumed; based on the theory of mathematical equation and energy method, the formulas of basic frequency of liquid-solid coupling vibration system are derived, the baffle joined to the tank wall with 3 kinds of boundary conditions, namely, four edges simply supported, two opposite edges clamped and two opposite edges simply supported, and four edges clamped; the influence rules of baffle length-width ratio, the ratio of baffle height to liquid level, baffle elastic modulus, baffle density, baffle thickness, and liquid density on the coupling vibration performance are studied. The results show that the frequency of the clamped boundary is minimum; the influences of baffle length-width ratio and relative height on the basic frequency are much greater than that of the other system parameters; the relation between baffle length-width ratio and the frequency is exponential, while baffle relative height has a parabola relation with the frequency; the larger the baffle length-width ratio, the closer the baffle to the liquid level; the coupling frequency will be reduced more obviously.

  9. Radiant{trademark} Liquid Radioisotope Intravascular Radiation Therapy System

    Energy Technology Data Exchange (ETDEWEB)

    Eigler, N.; Whiting, J.; Chernomorsky, A.; Jackson, J.; Knapp, F.F., Jr.; Litvack, F.

    1998-01-16

    RADIANT{trademark} is manufactured by United States Surgical Corporation, Vascular Therapies Division, (formerly Progressive Angioplasty Systems). The system comprises a liquid {beta}-radiation source, a shielded isolation/transfer device (ISAT), modified over-the-wire or rapid exchange delivery balloons, and accessory kits. The liquid {beta}-source is Rhenium-188 in the form of sodium perrhenate (NaReO{sub 4}), Rhenium-188 is primarily a {beta}-emitter with a physical half-life of 17.0 hours. The maximum energy of the {beta}-particles is 2.1 MeV. The source is produced daily in the nuclear pharmacy hot lab by eluting a Tungsten-188/Rhenium-188 generator manufactured by Oak Ridge National Laboratory (ORNL). Using anion exchange columns and Millipore filters the effluent is concentrated to approximately 100 mCi/ml, calibrated, and loaded into the (ISAT) which is subsequently transported to the cardiac catheterization laboratory. The delivery catheters are modified Champion{trademark} over-the-wire, and TNT{trademark} rapid exchange stent delivery balloons. These balloons have thickened polyethylene walls to augment puncture resistance; dual radio-opaque markers and specially configured connectors.

  10. Controlling liquid splash on superhydrophobic surfaces by a vesicle surfactant

    Science.gov (United States)

    Song, Meirong; Ju, Jie; Luo, Siqi; Han, Yuchun; Dong, Zhichao; Wang, Yilin; Gu, Zhen; Zhang, Lingjuan; Hao, Ruiran; Jiang, Lei

    2017-01-01

    Deposition of liquid droplets on solid surfaces is of great importance to many fundamental scientific principles and technological applications, such as spraying, coating, and printing. For example, during the process of pesticide spraying, more than 50% of agrochemicals are lost because of the undesired bouncing and splashing behaviors on hydrophobic or superhydrophobic leaves. We show that this kind of splashing on superhydrophobic surfaces can be greatly inhibited by adding a small amount of a vesicular surfactant, Aerosol OT. Rather than reducing splashing by increasing the viscosity via polymer additives, the vesicular surfactant confines the motion of liquid with the help of wettability transition and thus inhibits the splash. Significantly, the vesicular surfactant exhibits a distinguished ability to alter the surface wettability during the first inertial spreading stage of ~2 ms because of its dense aggregates at the air/water interface. A comprehensive model proposed by this idea could help in understanding the complex interfacial interactions at the solid/liquid/air interface. PMID:28275735

  11. Identifying Liquid-Gas System Misconceptions and Addressing Them Using a Laboratory Exercise on Pressure-Temperature Diagrams of a Mixed Gas Involving Liquid-Vapor Equilibrium

    Science.gov (United States)

    Yoshikawa, Masahiro; Koga, Nobuyoshi

    2016-01-01

    This study focuses on students' understandings of a liquid-gas system with liquid-vapor equilibrium in a closed system using a pressure-temperature ("P-T") diagram. By administrating three assessment questions concerning the "P-T" diagrams of liquid-gas systems to students at the beginning of undergraduate general chemistry…

  12. Identifying Liquid-Gas System Misconceptions and Addressing Them Using a Laboratory Exercise on Pressure-Temperature Diagrams of a Mixed Gas Involving Liquid-Vapor Equilibrium

    Science.gov (United States)

    Yoshikawa, Masahiro; Koga, Nobuyoshi

    2016-01-01

    This study focuses on students' understandings of a liquid-gas system with liquid-vapor equilibrium in a closed system using a pressure-temperature ("P-T") diagram. By administrating three assessment questions concerning the "P-T" diagrams of liquid-gas systems to students at the beginning of undergraduate general chemistry…

  13. Dressage, Control, and Enterprise Systems

    DEFF Research Database (Denmark)

    Gal, Uri; Berente, Nicholas; Yoo, Youngjin

    2010-01-01

    In 2004, National Aeronautics and Space Administration (NASA) implemented Full Cost, an activity-based accounting program through an agency-wide enterprise resource planning (ERP) implementation. We apply Foucault's notion of 'dressage' to highlight aspects of demonstrative control associated...... with this implementation effort and to outline the different dimensions along which control was distributed. We suggest that some elements of Full Cost and the ERP system were geared toward satisfying disciplinary requirements without necessarily contributing to productive activity. We term these elements dressage...... that the ideal of complete enterprise control remains unattainable, as aspects of demonstrative control are inevitably implicated within broader enterprise-wide control systems within contemporary organizations. We conclude with implications for research and practice....

  14. Development of systems for the laser synthesis of nanoparticles starting from liquid precursors

    Energy Technology Data Exchange (ETDEWEB)

    Popovici, E., E-mail: popovici05@yahoo.co.uk [National Institute for Laser, Plasma and Radiation Physics, Laser Department, Laser Photochemistry Laboratory, P.O. Box MG-36, Atomistilor 409 St., R 077125 Bucharest (Romania); Luculescu, C.; Alexandrescu, R.; Fleaca, C.; Dumitrache, F.; Barjega, R.; Scarisoreanu, M.; Dutu, E.; Barbut, A.; Morjan, I. [National Institute for Laser, Plasma and Radiation Physics, Laser Department, Laser Photochemistry Laboratory, P.O. Box MG-36, Atomistilor 409 St., R 077125 Bucharest (Romania); Vasile, E. [SC-METAV SA, Strada C.A. Rosetti, Nr. 31, cod 020011 Bucuresti (Romania)

    2012-09-15

    Highlights: Black-Right-Pointing-Pointer An original evaporator system was designed and instrumentation was developed. Black-Right-Pointing-Pointer The process occurs in the gas phase, over the boiling temperature of the substances. Black-Right-Pointing-Pointer The control system allows the maintaining of the overall system temperature. - Abstract: The laser synthesis of nanoparticles starting from liquid precursors is particularly suitable as synthesis technique for obtaining nanoparticles. In the present work the laser pyrolysis is performed in a novel setup where the liquid precursor is brought with the aid of an original evaporator system to temperatures in excess of the boiling point and is finally fed into the reactor under the form of heated vapors.The process occurs in the gas phase and ensures the avoidance of the condensation. The temperature control system allows for the maintaining of the overall system temperature below the decomposition temperature and above the boiling. Temperatures up to 500 Degree-Sign C are assured for the mixed precursors. The control of the amount of the active substances is performed upstream, in the liquid phase. The set-up is able to offer safety conditions at the synthesis of substances with high toxicity. This experimental set-up was proposed in order to synthesize TiO{sub 2} nanoparticles from TTIP because its boiling temperature is relatively high (239 Degree-Sign C grades). Different analytical techniques such as EDX, TEM, XRD and HRTEM were used in order to evaluate the structural characteristics of the produced nanopowders.

  15. Balanced bridge feedback control system

    Science.gov (United States)

    Lurie, Boris J. (Inventor)

    1990-01-01

    In a system having a driver, a motor, and a mechanical plant, a multiloop feedback control apparatus for controlling the movement and/or positioning of a mechanical plant, the control apparatus has a first local bridge feedback loop for feeding back a signal representative of a selected ratio of voltage and current at the output driver, and a second bridge feedback loop for feeding back a signal representative of a selected ratio of force and velocity at the output of the motor. The control apparatus may further include an outer loop for feeding back a signal representing the angular velocity and/or position of the mechanical plant.

  16. The AFP Detector Control System

    CERN Document Server

    Oleiro Seabra, Luis Filipe; The ATLAS collaboration

    2017-01-01

    The ATLAS Forward Proton (AFP) detector is one of the forward detectors of the ATLAS experiment at CERN aiming at measuring momenta and angles of diffractively scattered protons. Silicon Tracking and Time-of-Flight detectors are located inside Roman Pot stations inserted into beam pipe aperture. The AFP detector is composed of two stations on each side of the ATLAS interaction point and is under commissioning. The detector is provided with high and low voltage distribution systems. Each station has vacuum and cooling systems, movement control and all the required electronics for signal processing. Monitoring of environmental parameters, like temperature and radiation, is also available. The Detector Control System (DCS) provides control and monitoring of the detector hardware and ensures the safe and reliable operation of the detector, assuring good data quality. Comparing with DCS systems of other detectors, the AFP DCS main challenge is to cope with the large variety of AFP equipment. This paper describes t...

  17. Distributed control system for vehicles

    Science.gov (United States)

    Callen, Jeffrey N.; Iaconis, John M.

    1997-01-01

    Previously, control systems for remotely controlled vehicles (RCVs) and unmanned ground vehicles (UGVs) have largely been of a centralized design, in which all vehicles sensing and servo control systems are individually interfaces to a central computer. These controllers often have been completely redeveloped for each new application. This approach leads to increased development, installation, and maintenance costs, and to a product that is not easily adaptable to other platforms or tasks. Under a Phase II SBIR program, RedZone Robotics is developing a distributed control systems (DCS) that reduces development, installation, and maintenance costs while enhancing adaptability to other platforms or applications. The DCS consists of a distributed control network of small, intelligent local controller nodes acting on the vehicle motion and sensing system components. A central card oversees the network and handles higher level commands. The central card and local nodes are linked through the controller area network serial bus. The node hardware is of standardized design so that application specific tasks are largely accomplished in software. The standardized design makes the DCS potentially compatible with multiple UGV platforms and eventual dual-use applications in commercial vehicles. More sophisticated functionality, such as remote control or autonomous navigation can be layered on top of the low level control supplied by DCS. Thus, the DCS can be an enabling component for development of advanced UGV technologies. ALso, intelligent nodes enable fault identification and orderly shutdown to be accomplished directly at the vehicle actuators. This SBIR is sponsored by the US Army Tank-Automotive Research, Development and Engineering Center.

  18. Control of NASA's Space Launch System

    Science.gov (United States)

    VanZwieten, Tannen S.

    2014-01-01

    The flight control system for the NASA Space Launch System (SLS) employs a control architecture that evolved from Saturn, Shuttle & Ares I-X while also incorporating modern enhancements. This control system, baselined for the first unmanned launch, has been verified and successfully flight-tested on the Ares I-X rocket and an F/A-18 aircraft. The development of the launch vehicle itself came on the heels of the Space Shuttle retirement in 2011, and will deliver more payload to orbit and produce more thrust than any other vehicle, past or present, opening the way to new frontiers of space exploration as it carries the Orion crew vehicle, equipment, and experiments into new territories. The initial 70 metric ton vehicle consists of four RS-25 core stage engines from the Space Shuttle inventory, two 5- segment solid rocket boosters which are advanced versions of the Space Shuttle boosters, and a core stage that resembles the External Tank and carries the liquid propellant while also serving as the vehicle's structural backbone. Just above SLS' core stage is the Interim Cryogenic Propulsion Stage (ICPS), based upon the payload motor used by the Delta IV Evolved Expendable Launch Vehicle (EELV).

  19. Cryogenic System for the Test Facilities of the ATLAS Liquid Argon Calorimeter Modules

    CERN Document Server

    Bremer, J; Chalifour, M; Haug, F; Passardi, Giorgio; Tischhauser, Johann

    1998-01-01

    To perform cold tests on the different modules of the ATLAS liquid argon calorimeter, a cryogenic system has been constructed and is now operated at the CERN North Experimental Area. Three different test cryostats will house the modules, which can also be exposed to particle beams for calibration purposes. The three cryostats share a common liquid argon and liquid nitrogen distribution system. The system is rather complex since it has to allow operations of the three cryostats at the same time. Liquid nitrogen is used as cold source for both the cool-down of the cryostats and for normal operation of the cryostats filled with liquid argon.

  20. Chaos Control in Mechanical Systems

    Directory of Open Access Journals (Sweden)

    Marcelo A. Savi

    2006-01-01

    Full Text Available Chaos has an intrinsically richness related to its structure and, because of that, there are benefits for a natural system of adopting chaotic regimes with their wide range of potential behaviors. Under this condition, the system may quickly react to some new situation, changing conditions and their response. Therefore, chaos and many regulatory mechanisms control the dynamics of living systems, conferring a great flexibility to the system. Inspired by nature, the idea that chaotic behavior may be controlled by small perturbations of some physical parameter is making this kind of behavior to be desirable in different applications. Mechanical systems constitute a class of system where it is possible to exploit these ideas. Chaos control usually involves two steps. In the first, unstable periodic orbits (UPOs that are embedded in the chaotic set are identified. After that, a control technique is employed in order to stabilize a desirable orbit. This contribution employs the close-return method to identify UPOs and a semi-continuous control method, which is built up on the OGY method, to stabilize some desirable UPO. As an application to a mechanical system, a nonlinear pendulum is considered and, based on parameters obtained from an experimental setup, analyses are carried out. Signals are generated by numerical integration of the mathematical model and two different situations are treated. Firstly, it is assumed that all state variables are available. After that, the analysis is done from scalar time series and therefore, it is important to evaluate the effect of state space reconstruction. Delay coordinates method and extended state observers are employed with this aim. Results show situations where these techniques may be used to control chaos in mechanical systems.

  1. MODELING VAPOR LIQUID EQUILIBRIUM OF IONIC LIQUIDS plus GAS BINARY SYSTEMS AT HIGH PRESSURE WITH CUBIC EQUATIONS OF STATE

    OpenAIRE

    Freitas, ACD; Cunico, LP; M. Aznar; Guirardello,R.

    2013-01-01

    Ionic liquids (IL) have been described as novel environmentally benign solvents because of their remarkable characteristics. Numerous applications of these solvents continue to grow at an exponential rate. In this work, high pressure vapor liquid equilibria for 17 different IL + gas binary systems were modeled at different temperatures with Peng-Robinson (PR) and Soave-Redlich-Kwong (SRK) equations of state, combined with the van der Waals mixing rule with two binary interaction parameters (v...

  2. Learning fuzzy logic control system

    Science.gov (United States)

    Lung, Leung Kam

    1994-01-01

    The performance of the Learning Fuzzy Logic Control System (LFLCS), developed in this thesis, has been evaluated. The Learning Fuzzy Logic Controller (LFLC) learns to control the motor by learning the set of teaching values that are generated by a classical PI controller. It is assumed that the classical PI controller is tuned to minimize the error of a position control system of the D.C. motor. The Learning Fuzzy Logic Controller developed in this thesis is a multi-input single-output network. Training of the Learning Fuzzy Logic Controller is implemented off-line. Upon completion of the training process (using Supervised Learning, and Unsupervised Learning), the LFLC replaces the classical PI controller. In this thesis, a closed loop position control system of a D.C. motor using the LFLC is implemented. The primary focus is on the learning capabilities of the Learning Fuzzy Logic Controller. The learning includes symbolic representation of the Input Linguistic Nodes set and Output Linguistic Notes set. In addition, we investigate the knowledge-based representation for the network. As part of the design process, we implement a digital computer simulation of the LFLCS. The computer simulation program is written in 'C' computer language, and it is implemented in DOS platform. The LFLCS, designed in this thesis, has been developed on a IBM compatible 486-DX2 66 computer. First, the performance of the Learning Fuzzy Logic Controller is evaluated by comparing the angular shaft position of the D.C. motor controlled by a conventional PI controller and that controlled by the LFLC. Second, the symbolic representation of the LFLC and the knowledge-based representation for the network are investigated by observing the parameters of the Fuzzy Logic membership functions and the links at each layer of the LFLC. While there are some limitations of application with this approach, the result of the simulation shows that the LFLC is able to control the angular shaft position of the

  3. Design and development of a helium injection system to improve external leakage detection during liquid nitrogen immersion tests

    Science.gov (United States)

    Townsend, Andrew; Mishra, Rakesh

    2016-10-01

    The testing of assemblies for use in cryogenic systems commonly includes evaluation at or near operating (therefore cryogenic) temperature. Typical assemblies include valves and pumps for use in liquid oxygen-liquid hydrogen rocket engines. One frequently specified method of cryogenic external leakage testing requires the assembly, pressurized with gaseous helium (GHe), be immersed in a bath of liquid nitrogen (LN2) and allowed to thermally stabilize. Component interfaces are then visually inspected for leakage (bubbles). Unfortunately the liquid nitrogen will be boiling under normal, bench-top, test conditions. This boiling tends to mask even significant leakage. One little known and perhaps under-utilized property of helium is the seemingly counter-intuitive thermodynamic property that when ambient temperature helium is bubbled through boiling LN2 at a temperature of -195.8 °C, the temperature of the liquid nitrogen will reduce. This paper reports on the design and testing of a novel proof-of-concept helium injection control system confirming that it is possible to reduce the temperature of an LN2 bath below boiling point through the controlled injection of ambient temperature gaseous helium and then to efficiently maintain a reduced helium flow rate to maintain a stabilized liquid temperature, enabling clear visual observation of components immersed within the LN2. Helium saturation testing is performed and injection system sizing is discussed.

  4. Control System for the NSTX Lithium Pellet Injector

    Energy Technology Data Exchange (ETDEWEB)

    P. Sichta; J. Dong; R. Gernhardt; G. Gettelfinger; H. Kugel

    2003-10-27

    The Lithium Pellet Injector (LPI) is being developed for the National Spherical Torus Experiment (NSTX). The LPI will inject ''pellets'' of various composition into the plasma in order to study wall conditioning, edge impurity transport, liquid limiter simulations, and other areas of research. The control system for the NSTX LPI has incorporated widely used advanced technologies, such as LabVIEW and PCI bus I/O boards, to create a low-cost control system which is fully integrated into the NSTX computing environment. This paper will present the hardware and software design of the computer control system for the LPI.

  5. Plasma Reforming of Liquid Hydrocarbon Fuels in Non-Thermal Plasma-Liquid Systems

    Science.gov (United States)

    2010-04-30

    channel with liquid wall in the microporous media under the ultrasound cavitations has shown the following: · The action of the ultrasound field in the...microporous liquid which has a very large ratio of the plasma-liquid contact surface to the plasma volume. As is known the ultrasonic (US) cavitation is a very...2) and it ran over a flat dielectric surface of the magnetostrictive transmitter (5) which produced ultrasonic (US) cavitations , so the discharge

  6. Biomimetic Synthesis of CdSe Quantum Dots through Emulsion Liquid Membrane System of Gas-Liquid Transport

    Institute of Scientific and Technical Information of China (English)

    LIU,LU(刘璐); WU,Qing-Sheng,(吴庆生); DING,Ya-Ping(丁亚平); LIU,Hua-Jie(柳华杰); ZHANG,Bao-Quan(张保权)

    2004-01-01

    The cadmium selenide quantum dots (QD) have been synthesized by template-control in an emulsion liquid membrane system.The system consisted of kerosene as solvent,L152 (dialkylene succinimide) as surfactant,N7301 (trialiphatic amine,R3N,R=Cs-C10) as carrier,0.1 mol/L CdC12 solution as internal-aqueous phase and H2Se gas as external phase.Additive organic template agent in internal-aqueous phase was necessary to form CdSe QD.The influence of the nature of template and its concentration on sizes of the formed CdSe QD has also been studied.Transmission electron microscopy showed that the sizes of the products could be controlled down to 3-4nm.X-ray diffraction analysis revealed that the crystals had cubic structure.The formation process and the optical properties of CdSe QD have also been presented.

  7. Universality classes and critical phenomena in confined liquid systems

    Directory of Open Access Journals (Sweden)

    A.V. Chalyi

    2013-06-01

    Full Text Available It is well known that the similar universal behavior of infinite-size (bulk systems of different nature requires the same basic conditions: space dimensionality; number components of order parameter; the type (short- or long-range of the intermolecular interaction; symmetry of the fluctuation part of thermodynamical potential. Basic conditions of similar universal behavior of confined systems needs the same supplementary conditions such as the number of monolayers for a system confinement; low crossover dimensionality, i.e., geometric form of restricted volume; boundary conditions on limiting surfaces; physical properties under consideration. This review paper is aimed at studying all these conditions of similar universal behavior for diffusion processes in confined liquid systems. Special attention was paid to the effects of spatial dispersion and low crossover dimensionality. This allowed us to receive receiving correct nonzero expressions for the diffusion coefficient at the critical point and to take into account the specific geometric form of the confined liquid volume. The problem of 3D⇔2D dimensional crossover was analyzed. To receive a smooth crossover for critical exponents, the Kawasaki-like approach from the theory of mode coupling in critical dynamics was proposed. This ensured a good agreement between data of computer experiment and theoretical calculations of the size dependence of the critical temperature Tc(H of water in slitlike pores. The width of the quasi-elastic scattering peak of slow neutrons near the structural phase transition in the aquatic suspensions of plasmatic membranes (mesostructures with the typical thickness up to 10 nm was studied. It was shown that the width of quasi-elastic peak of neutron scattering decreases due to the process of cell proliferation, i.e., with an increase of the membrane size (including the membrane thickness. Thus, neutron studies could serve as an additional diagnostic test for the

  8. On the molecular anisotropy of liquid crystalline and flexible polymer systems

    Science.gov (United States)

    van Horn, Brett L.

    The demand for products of ever increasing quality or for novel applications has required increasing attention to or manipulation of the anisotropy of manufactured parts. Oriented plastics are used everywhere from recording film to automotive body parts to monofilament fishing line. Liquid crystals are also used in a wide array of applications including their dominance in the flat panel display industry, color changing temperature sensors, and woven bullet resistant fabrics. Anisotropy can also be detrimental, for instance sometimes leading to poor fracture resistance or low yield stress along specific directions. Controlling and measuring anisotropy of materials has become increasingly important, but doing so is wrought with challenges. Measuring physical properties of isotropic liquids, such as water or most oils can be done in a straightforward fashion. Their viscosities and densities, for example, have unique values under a given set of conditions. With anisotropic fluids, like liquid crystals, the viscosity, for instance, will not only depend upon temperature, concentration, etc. but also upon the direction of observation, degree of anisotropy, source of anisotropy, and so forth. This added degree of complexity complicates our ability to define the state of the material at which the measurements are made and generally necessitates the use of more sophisticated measurement strategies or techniques. This work presents techniques and tools for investigating anisotropy in liquid crystalline and stretched polymeric systems. Included are the use of conoscopy for the determination of birefringence and orientation of nematic liquid crystals and stretched polymers, the shear response of flow aligning nematic liquid crystal monodomains, and the design of a novel linear rheometer that allows for in situ optical or scattering investigations.

  9. The CERN SPS Control System

    CERN Multimedia

    CERN Neyrac Films

    2012-01-01

    Part of the series of films produced by CERN about the SPS. Names, facts and credits added on the 1975 version by Bengt Sagnell, Meyrin, Oct 2012. The project leader for the SPS accelerator (with 400 staff) was John Adams - later Sir John. The group responsible for the design and installation of the control system was led by Michael Crowley-Milling. 00:02:14 Bernard Sutton00:02:48 Michael Crowley-Milling, Head of the Controls Group00:03:01 Designed in the Controls Group, this was probably the first use of touch screens in an industrial control system00:04:37 Louis Burnod, Section leader, Beam Instrumentation00:05:36 Claes Frisk, Computer technician 00:06:03 The system contained 24 Norsk Data NORD-10 16-bit mini computers with 16-64 kB of magnetic core memory and external hard disks of from 5MB to 256 MB in size00:06:23 Frank Beck, Section leader, Central Controls00:06:26 Véronique Frammery, Programmer 00:06:31 Hans-Karl Kuhn, Power Supply Controls00:07:55 Raymond Rausch, Control electronics00:10:23 Paul Acti...

  10. Experimental analysis of beam pointing system based on liquid crystal optical phase array

    Science.gov (United States)

    Shi, Yubin; Zhang, Jianmin; Zhang, Zhen

    2016-12-01

    In this paper, we propose and demonstrate an elementary non-mechanical beam aiming and steering system with a single liquid crystal optical phase array (LC-OPA) and charge-coupled device (CCD). With the conventional method of beam steering control, the LC-OPA device can realize one dimensional beam steering continuously. An improved beam steering strategy is applied to realize two dimensional beam steering with a single LC-OPA. The whole beam aiming and steering system, including an LC-OPA and a retroreflective target, is controlled by the monitor. We test the feasibility of beam steering strategy both in one dimension and in two dimension at first, then the whole system is build up based on the improved strategy. The experimental results show that the max experimental pointing error is 56 μrad, and the average pointing error of the system is 19 μrad.

  11. The Nature and Assessment of Systemic Risk in Terms of Liquidity of the Banking System

    Directory of Open Access Journals (Sweden)

    Lavreniuk Vladyslav V.

    2016-11-01

    Full Text Available The aim of the article is to determine the nature of systemic risk as a threat to the financial stability of the banking system and develop analytical tools to assess its impact on the banking system in terms of its liquidity. To solve the tasks assigned, there used general scientific and specific methods, such as: logical and dialectical method, mathematical and graphical one. Based on the generalization, analysis and comparison of different interpretations, there clarified the concept of «systemic risk» as a risk generated by financial institutions or individual sectors through the implementation of the mechanism of risk transmission, achieving significant scale of distribution and adversely affecting the stability of the financial system and the real sector of economy. There identified key aspects of systemic risk: a systemic risk is not a sum of all individual risks of financial institutions; b spreads through the channels of interconnectedness between financial institutions; c is a result of accumulated structural imbalances; d affects the stability of the financial/banking system, public confidence and the real sector of economy. Analytical tools for estimation of the bank’s contribution to the systemic liquidity risk on the basis of which it is determined that the first place in terms of the effect on the aggregate systemic risk of liquidity of the Ukrainian banking system is occupied by banks of Group I, the second place — by Privatbank, the third, fourth, fifth places — by banks in Group II — Oschadbank, Ukreximbank. It is found that it is systemically important state-owned banks that have a significant impact on systemic liquidity risk. It is determined that the probability of default of a leading systemically important bank could result in considerable cumulative losses for the entire banking system and real economy. The prospects of further research are the development of tools for systemic risk assessment with respect to

  12. Advanced Supported Liquid Membranes for Carbon Dioxide Control in Cabin Applications

    Science.gov (United States)

    Wickham, David T.; Gleason, Kevin J.; Engel, Jeffrey R.; Chullen, Cinda

    2016-01-01

    The development of new, robust, life support systems is critical to NASA's continued progress in space exploration. One vital function is maintaining the carbon dioxide (CO2) concentration in the cabin at levels that do not impair the health or performance of the crew. The CO2 removal assembly (CDRA) is the current CO2 control technology on-board the International Space Station (ISS). Although the CDRA has met the needs of the ISS to date, the repeated cycling of the molecular sieve sorbent causes it to break down into small particles that clog filters or generate dust in the cabin. This reduces reliability and increases maintenance requirements. Another approach that has potential advantages over the current system is a membrane that separates CO2 from air. In this approach, cabin air contacts one side of the membrane while other side of the membrane is maintained at low pressure to create a driving force for CO2 transport across the membrane. In this application, the primary power requirement is for the pump that creates the low pressure and then pumps the CO2 to the oxygen recovery system. For such a membrane to be practical, it must have high CO2 permeation rate and excellent selectivity for CO2 over air. Unfortunately, conventional gas separation membranes do not have adequate CO2 permeability and selectivity to meet the needs of this application. However, the required performance could be obtained with a supported liquid membrane (SLM), which consists of a microporous material filled with a liquid that selectively reacts with CO2 over air. In a recently completed Phase II SBIR project, Reaction Systems, Inc. fabricated an SLM that is very close to meeting permeability and selectivity objectives for use in the advanced space suit portable life support system. This paper describes work carried out to evaluate its potential for use in spacecraft cabin application.

  13. Electrically controllable liquid crystal photonic bandgap fiber with dual-frequency control

    DEFF Research Database (Denmark)

    Scolari, Lara; Alkeskjold, Thomas Tanggaard; Riishede, Jesper

    2005-01-01

    We present an electrically tunable liquid crystal photonic bandgap fiber device based on a dual frequency liquid crystal with pre-tilted molecules that allows the bandgaps to be continuously tuned. The frequency dependent behavior of the liquid crystal enables active shifting of the bandgaps toward...

  14. Integration of Fire Control, Flight Control and Propulsion Control Systems.

    Science.gov (United States)

    1983-08-01

    system, the answer was by a comprehensive programme of simulation and rig testing. ix In the only paper in the programme deailing with systems for civil ...be used otherwise. At one time there was an explosive growth in the application of automatic flight control to civil transport aircraft, culminating in...nombre at l’ampleur des 6quipesenta de maintenance extgrieurs a lavion, 11 faut s’efforcer I ce qua 1. mayan privil~gif pareattant lea 6changss

  15. Control synthesis of switched systems

    CERN Document Server

    Zhao, Xudong; Niu, Ben; Wu, Tingting

    2017-01-01

    This book offers its readers a detailed overview of the synthesis of switched systems, with a focus on switching stabilization and intelligent control. The problems investigated are not only previously unsolved theoretically but also of practical importance in many applications: voltage conversion, naval piloting and navigation and robotics, for example. The book considers general switched-system models and provides more efficient design methods to bring together theory and application more closely than was possible using classical methods. It also discusses several different classes of switched systems. For general switched linear systems and switched nonlinear systems comprising unstable subsystems, it introduces novel ideas such as invariant subspace theory and the time-scheduled Lyapunov function method of designing switching signals to stabilize the underlying systems. For some typical switched nonlinear systems affected by various complex dynamics, the book proposes novel design approaches based on inte...

  16. Proton beam therapy control system

    Science.gov (United States)

    Baumann, Michael A.; Beloussov, Alexandre V.; Bakir, Julide; Armon, Deganit; Olsen, Howard B.; Salem, Dana

    2010-09-21

    A tiered communications architecture for managing network traffic in a distributed system. Communication between client or control computers and a plurality of hardware devices is administered by agent and monitor devices whose activities are coordinated to reduce the number of open channels or sockets. The communications architecture also improves the transparency and scalability of the distributed system by reducing network mapping dependence. The architecture is desirably implemented in a proton beam therapy system to provide flexible security policies which improve patent safety and facilitate system maintenance and development.

  17. Proton beam therapy control system

    Science.gov (United States)

    Baumann, Michael A.; Beloussov, Alexandre V.; Bakir, Julide; Armon, Deganit; Olsen, Howard B.; Salem, Dana

    2008-07-08

    A tiered communications architecture for managing network traffic in a distributed system. Communication between client or control computers and a plurality of hardware devices is administered by agent and monitor devices whose activities are coordinated to reduce the number of open channels or sockets. The communications architecture also improves the transparency and scalability of the distributed system by reducing network mapping dependence. The architecture is desirably implemented in a proton beam therapy system to provide flexible security policies which improve patent safety and facilitate system maintenance and development.

  18. Phase control of excitable systems

    Energy Technology Data Exchange (ETDEWEB)

    Zambrano, S; Seoane, J M; Marino, I P; Sanjuan, M A F [Nonlinear Dynamics and Chaos Group, Departamento de Fisica, Universidad Rey Juan Carlos, Tulipan s/n, 28933 Mostoles, Madrid (Spain); Euzzor, S; Meucci, R; Arecchi, F T [CNR-Istituto Nazionale di Ottica Applicata, Largo E. Fermi, 6 50125 Firenze (Italy)], E-mail: samuel.zambrano@urjc.es, E-mail: jesus.seoane@urjc.es, E-mail: ines.perez@urjc.es

    2008-07-15

    Here we study how to control the dynamics of excitable systems by using the phase control technique. Excitable systems are relevant in neuronal dynamics and therefore this method might have important applications. We use the periodically driven FitzHugh-Nagumo (FHN) model, which displays both spiking and non-spiking behaviours in chaotic or periodic regimes. The phase control technique consists of applying a harmonic perturbation with a suitable phase {phi} that we adjust in search of different behaviours of the FHN dynamics. We compare our numerical results with experimental measurements performed on an electronic circuit and find good agreement between them. This method might be useful for a better understanding of excitable systems and different phenomena in neuronal dynamics.

  19. The STAR Online Control System

    Science.gov (United States)

    Gilkes, M. L.; Chrin, J.; Olchanski, K.; Pruneau, C. A.; Stone, N. T. B.; Wenaus, T.

    1998-10-01

    The STAR Online Software Group has designed and built a complete control system for the STAR experiment. We support SUN Solaris and Windows NT, and utilize commercial software packages including Orbix (C++) for CORBA IPC, Objectivity/DB (C++) for the configuration database, Borland JBuilder for Java GUI development, EPICS and CDEV for hardware interfacing, and RogueWave libraries (STL, Tools.h++, Threads.h++, Net.h++). The system embodies a unified object-oriented approach to experiment control. Device-specific details are encapsulated in a single server unique to each subsystem (i.e. DAQ, Trigger, sub-detectors). Key online system features include management of subsystem states, configuration management, CORBA messaging, arbitration and synchronization of multiple runs, participation of subsystems in multiple runs, a user interface incorporating ROOT and its C++ interpreter for scripting, JAVA control GUIs with automatic logging, and an online event pool from which consumers can interactively select events.

  20. The CMS Detector Control System

    CERN Document Server

    Gomez-Reino Garrido, Robert

    2009-01-01

    The Compact Muon Solenoid (CMS) experiment at CERN is one of the Large Hadron Collider multi-purpose experiments. Its large subsystems size sum up to around 6 million Detector Control System (DCS) channels to be supervised. A cluster of ~100 servers is needed to provide the required processing resources. To cope with such a size a scalable approach has been chosen factorizing the DCS system as much as possible. CMS DCS has made a clear division between its computing resources and functionality by creating a computing framework allowing for plugging in functional components. DCS components are developed by the subsystems expert groups while the computing infrastructure is developed centrally. To ease the component development task, a framework based on PVSSII [1] has been developed by the CERN Joint Controls Project [2] (JCOP). This paper describes the current status of CMS Detector Control System, giving an overview of the DCS computing infrastructure, the integration of DCS subsystem functional components an...

  1. Power system dynamics and control

    CERN Document Server

    Kwatny, Harry G

    2016-01-01

    This monograph explores a consistent modeling and analytic framework that provides the tools for an improved understanding of the behavior and the building of efficient models of power systems. It covers the essential concepts for the study of static and dynamic network stability, reviews the structure and design of basic voltage and load-frequency regulators, and offers an introduction to power system optimal control with reliability constraints. A set of Mathematica tutorial notebooks providing detailed solutions of the examples worked-out in the text, as well as a package that will enable readers to work out their own examples and problems, supplements the text. A key premise of the book is that the design of successful control systems requires a deep understanding of the processes to be controlled; as such, the technical discussion begins with a concise review of the physical foundations of electricity and magnetism. This is followed by an overview of nonlinear circuits that include resistors, inductors, ...

  2. Three-dimensional positioning and control of colloidal objects utilizing engineered liquid crystalline defect networks.

    Science.gov (United States)

    Yoshida, H; Asakura, K; Fukuda, J; Ozaki, M

    2015-05-21

    Topological defects in liquid crystals not only affect the optical and rheological properties of the host, but can also act as scaffolds in which to trap nano or micro-sized colloidal objects. The creation of complex defect shapes, however, often involves confining the liquid crystals in curved geometries or adds complex-shaped colloidal objects, which are unsuitable for device applications. Using topologically patterned substrates, here we demonstrate the controlled generation of three-dimensional defect lines with non-trivial shapes and even chirality, in a flat slab of nematic liquid crystal. By using the defect lines as templates and the electric response of the liquid crystals, colloidal superstructures are constructed, which can be reversibly reconfigured at a voltage as low as 1.3 V. Three-dimensional engineering of the defect shapes in liquid crystals is potentially useful in the fabrication of self-healing composites and in stabilizing artificial frustrated phases.

  3. Advanced Light Source control system

    Energy Technology Data Exchange (ETDEWEB)

    Magyary, S.; Chin, M.; Cork, C.; Fahmie, M.; Lancaster, H.; Molinari, P.; Ritchie, A.; Robb, A.; Timossi, C.

    1989-03-01

    The Advanced Light Source (ALS) is a third generation 1--2 GeV synchrotron radiation source designed to provide ports for 60 beamlines. It uses a 50 MeV electron linac and 1.5 GeV, 1 Hz, booster synchrotron for injection into a 1--2 GeV storage ring. Interesting control problems are created because of the need for dynamic closed beam orbit control to eliminate interaction between the ring tuning requirements and to minimize orbit shifts due to ground vibrations. The extremely signal sensitive nature of the experiments requires special attention to the sources of electrical noise. These requirements have led to a control system design which emphasizes connectivity at the accelerator equipment end and a large I/O bandwidth for closed loop system response. Not overlooked are user friendliness, operator response time, modeling, and expert system provisions. Portable consoles are used for local operation of machine equipment. Our solution is a massively parallel system with >120 Mbits/sec I/O bandwidth and >1500 Mips computing power. At the equipment level connections are made using over 600 powerful Intelligent Local Controllers (ILC-s) mounted in 3U size Eurocard slots using fiber-optic cables between rack locations. In the control room, personal computers control and display all machine variables at a 10 Hz rate including the scope signals which are collected though the control system. Commercially available software and industry standards are used extensively. Particular attention is paid to reliability, maintainability and upgradeability. 10 refs., 11 figs.

  4. Control System of the Bepcii

    CERN Document Server

    Zhao, J; Kong, X C; Lei, G; Xu, S F; Le, Q

    2001-01-01

    Recently the Chinese Academy of Sciences has chosen BEPCII as the future development of the BEPC, i.e. upgrade of both the machine and detector. The luminosity of the machine is expected to increase to 1.0x1033cm-2s-1. The project will be started at the beginning of 2002 and finished with in 3-4 years. The BEPC control system was built in 1987 and upgraded in 1994. According to the design of the BEPCII, a double ring schema will be adopted and a number of new devices will be added in the system. The existing control system has to be upgraded. The BEPCII will be distributed architecture and developed by EPICS. We are going to apply the standard hardware interfaces and mature technologies in the system. A number of VME IOCs will be added in the system and the feildbus, PLCs will be used as device control for some kind of equipment. We will keep the existing system in use, such as CAMAC modules and PC front-ends, and merge it into EPICS system. Recently the development of the prototype is in progress. This paper...

  5. 14 CFR 27.395 - Control system.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Control system. 27.395 Section 27.395... STANDARDS: NORMAL CATEGORY ROTORCRAFT Strength Requirements Control Surface and System Loads § 27.395 Control system. (a) The part of each control system from the pilot's controls to the control stops must...

  6. Controlling dynamics in diatomic systems

    Indian Academy of Sciences (India)

    Praveen Kumar; Harjinder Singh

    2007-09-01

    Controlling molecular energetics using laser pulses is exemplified for nuclear motion in two different diatomic systems. The problem of finding the optimized field for maximizing a desired quantum dynamical target is formulated using an iterative method. The method is applied for two diatomic systems, HF and OH. The power spectra of the fields and evolution of populations of different vibrational states during transitions are obtained.

  7. Study of the control-equilibrium of control systems

    Institute of Scientific and Technical Information of China (English)

    Liu Qiaoge; Fu Mengyin; Sun Changsheng

    2008-01-01

    Not so much had been talked about equilibrium in control area.On the basis of the phenomenon of balance,the concept of control-equilibrium and control-equilibrium of a control system is proposed.According to this theory,a perfect control method should not only guarantee stability of the system,but also ensure the control-equilibrium of the system.To achieve the control-equilibrium,feed-forward control is required.

  8. SMS BASED REMOTE CONTROL SYSTEM

    Directory of Open Access Journals (Sweden)

    Reecha Ranjan Singh , Sangeeta Agrawal , Saurabh Kapoor ,S. Sharma

    2011-08-01

    Full Text Available A modern world contains varieties of electronic equipment and systems like: TV, security system, Hi-fi equipment, central heating systems, fire alarm systems, security alarm systems, lighting systems, SET Top Box, AC (Air Conditioner etc., we need to handle, ON/OFF or monitor these electrical devices remotely or to communicate with these but, if you are not at the home or that place and you want to communicate with these device. So the new technology for handled these devices remotely and for communication to required the GSM, mobile technology, SMS (short message service and some hardware resources. SMS based remote control for home appliances is beneficial for the human generation, because mobile is most recently used technology nowadays.

  9. The Design and Scale-Up of Multiple-Impeller Fermenters for Liquid Film Controlled Processes

    Directory of Open Access Journals (Sweden)

    Labík, L.

    2013-05-01

    Full Text Available Mechanically agitated gas-liquid contactors are frequently used in the chemical, food and biochemical industries as fermenters and as hydrogenation or chlorination reactors. However wide is the usage of such vessels, their design is not based on chemical engineering data, but is still rather empirical. Thus, it is highly desirable to have a tool for the rational design of agitated gas-liquid contactors that is based on fundamental chemical engineering parameters that are transferable to other systems and operating conditions. Focusing on liquid film-controlled processes and using the data from fermenters of different scales, we develop kLa correlations that are suitable for scale-up. First, we discuss how to determine the proper experimental kLa values, which are not distorted by other equipment parameters as is the gas residence time. We demonstrate the possible kLa distortion on the pilot-plant experimental data by comparing the results obtained by two different experimental techniques. Further, we present physically correct kLa data for fully non-coalescent (sodium sulphate solution batch. The data are presented both for laboratory and pilot-plant fermenters. We identify the process parameters, the values of which are dependent on the vessel scale when operated under the same power input per volume, and, using these parameters, we develop common kLa correlations suitable to describe the data for various scales of the vessel. The correlations developed reduce the uncertainty in predicting the volume of industrial scale fermenters from almost 1/2 to 1/4 of their total volume, thereby enabling significant reductions in both the initial costs, and operating costs.

  10. The QUIJOTE TGI control system

    Science.gov (United States)

    Gómez-Reñasco, M. F.; Martín, Y.; Aguiar-González, M.; Cozar, J.; González-Cobos, N.; Hoyland, R.; Núñez Cagical, M.; Pérez-de-Taoro, M. R.; Sánchez-de la Rosa, V.; Vega-Moreno, A.; Viera-Curbelo, T.

    2016-07-01

    The QUIJOTE-CMB experiment (Q-U-I JOint TEnerife CMB experiment) has been described in previous publications. In particular, the architecture of the MFI instrument control system, the first of the three QUIJOTE instruments, was presented in [1]. In this paper we describe the control system architecture, hardware, and software, of the second QUIJOTE instrument, the TGI (Thirty GHz Instrument), which has been in the process of commissioning for a few weeks now. It is a 30 pixel 26-36 GHz polarimeter array mounted at the focus of the second QUIJOTE telescope. The polarimeter design is based on the QUIET polarimeter scheme, implementing phase switches of 90° and 180° to generate four states of polarisation. The TGI control system acquires the scientific signal of the four channels for each of the 30 polarimeters, sampled at 160 kHz; it controls the commutation of the 30 x 4 phase switches at 16 kHz or 8 kHz; it performs the acquisition and monitoring of the health of the complete instrument, acquiring housekeeping from the various subsystems and also controls the different operational modes of the telescope. It finally, implements a queue system that permits automation of the observations by allowing the programming of several days of observations with the minimum of human intervention. The acquisition system is based on a PXI-RT host from NI, the commutations of the phase switches are performed by a PXI-FPGA subsystem and the telescope control is based on an EtherCAT bus from Beckhoff.

  11. The ATLAS liquid Argon calorimeters read-out system

    CERN Document Server

    Blondel, A; Fayard, L; La Marra, D; Léger, A; Matricon, P; Perrot, G; Poggioli, L; Prast, J; Riu, I; Simion, S

    2004-01-01

    The calorimetry of the ATLAS experiment takes advantage of different detectors based on the liquid Argon (LAr) technology. Signals from the LAr calorimeters are processed by various stages before being delivered to the Data Acquisition system. The calorimeter cell signals are received by the front-end boards, which digitize a predetermined number of samples of the bipolar waveform and sends them to the Read-Out Driver (ROD) boards. The ROD board receives triggered data from 1028 calorimeter cells, and determines the precise energy and timing of the signals by processing the discrete samplings of the pulse. In addition, it formats the digital stream for the following elements of the DAQ chain, and performs monitoring. The architecture and functionality of the ATLAS LAr ROD board are discussed, along with the final design of the Processing Unit boards housing the Digital Signal Processors (DSP). (9 refs).

  12. Compositional and kinetic controls on liquid immiscibility in ferrobasalt-rhyolite volcanic and plutonic series

    Science.gov (United States)

    Charlier, Bernard; Namur, Olivier; Grove, Timothy L.

    2013-07-01

    We present major element compositions of basalts and their differentiation products for some major tholeiitic series. The dry, low-pressure liquid lines of descent are shown to approach or intersect the experimentally-defined compositional space of silicate liquid immiscibility. Ferrobasalt-rhyolite unmixing along tholeiitic trends in both volcanic and plutonic environments is supported by worldwide occurrence of immiscible globules in the mesostasis of erupted basalts, unmixed melt inclusions in cumulus phases of major layered intrusions such as Skaergaard and Sept Iles, and oxide-rich ferrogabbros closely associated with plagiogranites in the lower oceanic crust. Liquid immiscibility is promoted by low-pressure, anhydrous fractional crystallization that drives the low Al2O3, high FeO liquids into the two-liquid field. Kinetic controls can be important in the development of two-liquid separation. The undercooling that occurs at the slow cooling rates of plutonic environments promotes early development of liquid immiscibility at higher temperature. In contrast rapid cooling in erupted lavas leads to large undercoolings and liquid immiscibility develops at significantly lower temperatures. Unmixing leads to the development of a compositional gap characterized by the absence of intermediate compositions, a feature of many tholeiitic provinces. The compositions of experimental unmixed silica-rich melts coincide with those of natural rhyolites and plagiogranites with high FeOtot and low Al2O3, suggesting the potential role of large-scale separation of immiscible Si-rich liquid in the petrogenesis of late-stage residual melts. No trace of the paired ferrobasaltic melt is found in volcanic environments because of its uneruptable characteristics. Instead, Fe-Ti ± P-rich gabbros are the cumulate products of immiscible Fe-rich melts in plutonic settings. The immiscibility process may be difficult to identify because both melts crystallize the same phases with the same

  13. Design of an MCU-controlled laser liquid turbidimeter based on OPT101

    Science.gov (United States)

    Liu, Yang; Xu, Huiying

    2009-11-01

    With the rapid development of industry, accurate detection of liquid turbidity has attracted more and more attention, and been widely applied to many industries. According to the Mie scattering and the Rayleigh scattering law, this paper presents a novel design of laser liquid turbidimeter which uses the method of determining the turbidity by means of detecting the 90° scattered light. The entire detection system mainly consists of a 650nm red laser source, a light receiver (OPT101) and photoelectric conversion devices, an A/D converter, a data processing and controlling unit, a screen display device (LCD) and a power supply module. This turbidimeter is proved to be an intelligent instrument, which makes the process of measuring greatly simplified by displaying the result of turbidity in a digital form directly. It operates normally at a temperature range from 0 oC to 50 oC . From 0 NTU to 1000 NTU, the measuring ranges can be adjusted in accordance with the situation of samples automatically, and a single measurement takes about 1.608 ms. A high precision of 0.001 NTU is realized in our experiments. After repeated measurements, an average error of +/-2.2% is obtained, and the repeatability is less than 1%. Moreover, two measuring modes are provided, one can store and view the measuring records repeatedly, while the other can be used for batch testing with an additional alarm device. This turbidimeter possesses a good practicality either in laboratory measurement or in industrial and environmental inspection.

  14. TUNING OF GAUSSIAN STOCHASTIC-CONTROL SYSTEMS

    NARCIS (Netherlands)

    VANSCHUPPEN, JH

    1994-01-01

    A closed-loop system consisting of a control system and an adaptive controller will be called tuning for a specified control objective if the real system and the ideal system defined below achieve the same value for the control objective. The real system is the system consisting of the unknown contr

  15. Spherical tuned liquid damper for vibration control in wind turbines

    DEFF Research Database (Denmark)

    Chen, Jun-Ling; Georgakis, Christos T.

    2015-01-01

    A tuned liquid damper (TLD), which consisted of two-layer hemispherical containers, partially filled with water, was investigated as a cost-effective method to reduce the wind-induced vibration of wind turbines. A 1/20 scaled test model was designed to investigate its performance on the shaking...... table. Three groups of equivalent ground accelerations were inputted to simulate the wind-induced dynamic response under different load cases. The influence of rotors and nacelle was assumed to be a concentrated tip mass. A series of free and forced vibration experiments were performed on the shaking......% of the generalized mass. That is to say, the spherical TLD can effectively improve the anti-fatigue performance of the wind turbine tower....

  16. Satellite Attitude Control System Simulator

    Directory of Open Access Journals (Sweden)

    G.T. Conti

    2008-01-01

    Full Text Available Future space missions will involve satellites with great autonomy and stringent pointing precision, requiring of the Attitude Control Systems (ACS with better performance than before, which is function of the control algorithms implemented on board computers. The difficulties for developing experimental ACS test is to obtain zero gravity and torque free conditions similar to the SCA operate in space. However, prototypes for control algorithms experimental verification are fundamental for space mission success. This paper presents the parameters estimation such as inertia matrix and position of mass centre of a Satellite Attitude Control System Simulator (SACSS, using algorithms based on least square regression and least square recursive methods. Simulations have shown that both methods have estimated the system parameters with small error. However, the least square recursive methods have performance more adequate for the SACSS objectives. The SACSS platform model will be used to do experimental verification of fundamental aspects of the satellite attitude dynamics and design of different attitude control algorithm.

  17. HOTOL Command and Control Systems

    Science.gov (United States)

    Rowley, J. D.

    1988-04-01

    HOTOL is intended to provide a low cost means of delivering payloads to low earth orbit. The vehicle is thus designed for unmanned and largely autonomous operations with very limited contact with a ground station. This paper outlines the Command and Control Systems studies undertaken to date and proposed for future phases.

  18. Center for Intelligent Control Systems

    Science.gov (United States)

    1992-12-01

    CENTER FOR INTELLIGENT CONTROL SYSTEMS Brown Umiversity Harvard University Marsachomtta Institute of Tecnology PUBLICATIONS LIST CICS Number Authors...Equivalence of the Auction Algorithm for 11/1/92 Assignment and die e-Relaxation (Preflow- Push ) Method for Min Cost Flow 26

  19. Control of structure and growth of polymorphic crystalline thin films of amphiphilic molecules on liquid surfaces

    DEFF Research Database (Denmark)

    Weinbach, S.P.; Kjær, K.; Bouwman, W.G.;

    1994-01-01

    The spontaneous formation and coexistence of crystalline polymorphic trilayer domains in amphiphilic films at air-liquid interfaces is demonstrated by grazing incidence synchrotron x-ray diffraction. These polymorphic crystallites may serve as models for the early stages of crystal nucleation...... and growth, helping to elucidate the manner in which additives influence the progress of crystal nucleation, growth, and polymorphism and suggesting ways of selectively generating and controlling multilayers on liquid surfaces. Auxiliary molecules have been designed to selectively inhibit development...

  20. The Control System Modeling Language

    CERN Document Server

    Zagar, K; Sekoranja, M; Tkacik, G; Vodovnik, A; Zagar, Klemen; Plesko, Mark; Sekoranja, Matej; Tkacik, Gasper; Vodovnik, Anze

    2001-01-01

    The well-known Unified Modeling Language (UML) describes software entities, such as interfaces, classes, operations and attributes, as well as relationships among them, e.g. inheritance, containment and dependency. The power of UML lies in Computer Aided Software Engineering (CASE) tools such as Rational Rose, which are also capable of generating software structures from visual object definitions and relations. UML also allows add-ons that define specific structures and patterns in order to steer and automate the design process. We have developed an add-on called Control System Modeling Language (CSML). It introduces entities and relationships that we know from control systems, such as "property" representing a single controllable point/channel, or an "event" specifying that a device is capable of notifying its clients through events. Entities can also possess CSML-specific characteristics, such as physical units and valid ranges for input parameters. CSML is independent of any specific language or technology...

  1. Control of Unknown Chaotic Systems Based on Neural Predictive Control

    Institute of Scientific and Technical Information of China (English)

    LIDong-Mei; WANGZheng-Ou

    2003-01-01

    We introduce the predictive control into the control of chaotic system and propose a neural network control algorithm based on predictive control. The proposed control system stabilizes the chaotic motion in an unknown chaotic system onto the desired target trajectory. The proposed algorithm is simple and its convergence speed is much higher than existing similar algorithms. The control system can control hyperchaos. We analyze the stability of the control system and prove the convergence property of the neural controller. The theoretic derivation and simulations demonstrate the effectiveness of the algorithm.

  2. Salt effect of KBr on the liquid-liquid equilibrium of the water/ethanol/1-pentanol system

    Directory of Open Access Journals (Sweden)

    G.R. Santos

    2000-12-01

    Full Text Available Liquid-liquid equilibrium data for the water/ethanol/1-pentanol/potassium bromide systems were experimentally determined at 25° C and 40ºC. The experimental data were correlated through the NRTL and UNIFAC-Dortmund models for the activity coefficient, with the estimation of new binary interaction parameters for both models, corresponding to the salt-solvent and solvent-solvent interactions for the NRTL model and the ion-ion and solvent-ion interactions for the UNIFAC-Dortmund model. The results obtained have shown that the NRTL model was more able to represent equilibrium data for the studied systems.

  3. The ALMA Telescope Control System

    Science.gov (United States)

    Farris, A.; Marson, Ralph; Kern, Jeff

    2005-10-01

    The Atacama Large Millimeter Array (ALMA) is a joint project between North America, Europe and Japan. ALMA is an aperture synthesis radio telescope consisting of 50 12-meter antennas located at an elevation of 5,000 meters in Llano de Chajnantor, Chile. These antennas will operate at frequencies ranging from 31.3 GHz to 950 GHz. The antennas can be moved and placed in different configurations, with baselines between the antennas varying from 150 meters to 20 km. The 50 antennas are supplemented by sixteen additional ones, known as the ALMA Compact Array (ACA): 12 7-meter antennas and 4 12-meter antennas. The ALMA control system will consist of over 70 computers separated by distances of over 20 km. Two aspects of the system are apparent: its distributed nature and its need to accurately synchronize events across many computers separated by large distances. In this paper we describe key features of the architecture of the ALMA Control System, focusing on its properties as a distributed system and on the mechanisms employed to achieve its time synchronization goals. This control system is a distributed system that uses the ALMA Common Software (ACS) as a middleware system layered on top of CORBA. The architecture of the control system extensively employs the component/container model in ACS. In addition, the use of CORBA allows us to employ Java in the higher levels of the control system, leaving C++ to the lower time-critical levels. Python as a scripting language is used by astronomers, to craft standard observing programs, and engineers, in a testing and debugging mode. Key to the concept of an aperture synthesis telescope is a special purpose hardware system known as a correlator, responsible for making various delay model corrections and correlating the signals from the antennas. There are two correlators in ALMA, one for the array of 50 antennas and one for the ACA. This entire system operates under a control system that must synchronize events across the

  4. Modelling on fuzzy control systems

    Institute of Scientific and Technical Information of China (English)

    LI; Hongxing(李洪兴); WANG; Jiayin(王加银); MIAO; Zhihong(苗志宏)

    2002-01-01

    A kind of modelling method for fuzzy control systems is first proposed here, which is calledmodelling method based on fuzzy inference (MMFI). It should be regarded as the third modelling method thatis different from two well-known modelling methods, that is, the first modelling method, mechanism modellingmethod (MMM), and the second modelling method, system identification modelling method (SlMM). Thismethod can, based on the interpolation mechanism on fuzzy logic system, transfer a group of fuzzy inferencerules describing a practice system into a kind of nonlinear differential equation with variable coefficients, calledHX equations, so that the mathematical model of the system can be obtained. This means that we solve thedifficult problem of how to get a model represented as differential equations on a complicated or fuzzy controlsystem.

  5. System of thermostatic control on Peltier thermopiles and microprocessor control for a portable NMR relaxometer.

    Science.gov (United States)

    Anisimov, Alexander V; Teplov, Vadim Yu; Silkin, Nikolai I

    2002-02-01

    Liquid equipment for thermostatic control of samples with accuracy better than 0.1 degree C within the temperature range from -20 to +70 degree C is designed for small-sized NMR spectrometers. The difficulty in using this equipment is a thermomodule based on the Peltier effect. The temperature control system is based on a single crystal microcomputer. The equipment fits modern small-sized NMR spectrometers, which facilitates medical and biological studies.

  6. Feedback control of quantum system

    Institute of Scientific and Technical Information of China (English)

    DONG Dao-yi; CHEN Zong-hai; ZHANG Chen-bin; CHEN Chun-lin

    2006-01-01

    Feedback is a significant strategy for the control of quantum system.Information acquisition is the greatest difficulty in quantum feedback applications.After discussing several basic methods for information acquisition,we review three kinds of quantum feedback control strategies:quantum feedback control with measurement,coherent quantum feedback,and quantum feedback control based on cloning and recognition.The first feedback strategy can effectively acquire information,but it destroys the coherence in feedback loop.On the contrary,coherent quantum feedback does not destroy the coherence,but the capability of information acquisition is limited.However,the third feedback scheme gives a compromise between information acquisition and measurement disturbance.

  7. Lighting system with illuminance control

    DEFF Research Database (Denmark)

    2013-01-01

    The present invention relates to an illumination control system comprising a plurality of outdoor luminaries and a motorized service vehicle. Each luminaire comprises a controllable light source producing a light illuminance. The motorized service vehicle comprises a light sensor configured...... to detect the light illuminance generated by the controllable light source at the motorized service vehicle. The motorized service vehicle computes light illuminance data based on the detected light illuminance and transmits these to the outdoor luminaire through a wireless communication link or stores...... the light illuminance data on a data recording device of the motorized service vehicle. The outdoor luminaire receives may use the light illuminance data to set or adjust a light illuminance of the controllable light source....

  8. Testing of Liquid Metal Components for Nuclear Surface Power Systems

    Science.gov (United States)

    Polzin, K. A.; Pearson, J. B.; Godfroy, T. J.; Schoenfeld, M.; Webster, K.; Briggs, M. H.; Geng, S. M.; Adkins, H. E.; Werner, J. E.

    2010-01-01

    The capability to perform testing at both the module/component level and in near prototypic reactor configurations using a non-nuclear test methodology allowed for evaluation of two components critical to the development of a potential nuclear fission power system for the lunar surface. A pair of 1 kW Stirling power convertors, similar to the type that would be used in a reactor system to convert heat to electricity, were integrated into a reactor simulator system to determine their performance using pumped NaK as the hot side working fluid. The performance in the pumped-NaK system met or exceed the baseline performance measurements where the converters were electrically heated. At the maximum hot-side temperature of 550 C the maximum output power was 2375 watts. A specially-designed test apparatus was fabricated and used to quantify the performance of an annular linear induction pump that is similar to the type that could be used to circulate liquid metal through the core of a space reactor system. The errors on the measurements were generally much smaller than the magnitude of the measurements, permitting accurate performance evaluation over a wide range of operating conditions. The pump produced flow rates spanning roughly 0.16 to 5.7 l/s (2.5 to 90 GPM), and delta p levels from less than 1 kPa to 90 kPa (greater than 0.145 psi to roughly 13 psi). At the nominal FSP system operating temperature of 525 C the maximum efficiency was just over 4%.

  9. Continued Advancement of Supported Liquid Membranes for Carbon Dioxide Control in Extravehicular Activity Applications

    Science.gov (United States)

    Wickham, David T.; Gleason, Kevin J.; Engel, Jeffrey R.; Cowley, Scott W.; Chullen, Cinda

    2015-01-01

    The Development of a new, robust, portable life support system (PLSS) is currently a high NASA priority in order to support longer and safer extravehicular activity (EVA) missions that will be necessary as space travel extends to near-Earth asteroids and eventually Mars. One of the critical PLSS functions is maintaining the carbon dioxide (CO2) concentration in the suit at acceptable levels. The Metal Oxide (MetOx) canister has a finite CO2 adsorption capacity and therefore in order to extend mission times, the unit would have to be larger and heavier, which is undesirable; therefore new CO2 control technologies must be developed. While recent work has centered on the use of alternating sorbent beds that can be regenerated during the EVA, this strategy increases the system complexity and power consumption. A simpler approach is to use a membrane that vents CO2 to space but retains oxygen(O2). A membrane has many advantages over current technology: it is a continuous system with no theoretical capacity limit, it requires no consumables, and it requires no hardware for switching beds between absorption and regeneration. Conventional gas separation membranes do not have adequate selectivity for use in the PLSS, but the required performance could be obtained with a supported liquid membrane (SLM), which consists of a microporous film filled with a liquid that selectively reacts with CO2 over oxygen (O2). In a recently completed Phase II Small Business Innovative Research project, Reaction Systems developed a new reactive liquid that has effectively zero vapor pressure, making it an ideal candidate for use in an SLM. Results obtained with the SLM in a flat sheet configuration with representative pressures of CO2, O2, and water (H2O) have shown that the CO2 permeation rate and CO2/O2 selectivity requirements have been met. In addition, the SLM vents moisture to space very effectively. The SLM has also been prepared and tested in a hollow fiber form, which will be

  10. Mathematical Control of Complex Systems 2013

    OpenAIRE

    Zidong Wang; Hamid Reza Karimi; Bo Shen; Jun Hu; Hongli Dong; Xiao He

    2014-01-01

    Mathematical control of complex systems have already become an ideal research area for control engineers, mathematicians, computer scientists, and biologists to understand, manage, analyze, and interpret functional information/dynamical behaviours from real-world complex dynamical systems, such as communication systems, process control, environmental systems, intelligent manufacturing systems, transportation systems, and structural systems. This special issue aims to bring together the latest...

  11. INJECTION VOLUME CONTROL BY THERMAL WAY IN TRANSGENIC DNA MICRO-INJECTION SYSTEM

    Institute of Scientific and Technical Information of China (English)

    Zhang Ling; Zhang Yun; Yang Yimin; Chen Jinghua

    2004-01-01

    Nowdays there are several manual or half-automatic methods developed to drive the DNA micro-fluid of transgenic micro-injection and they often fail to control precisely the injection volume at picolitres level.Micro-size of the injector tip and viscosity of the DNA liquid also lead to dead area of volume control.An adequate way is presented utilizing temperature gradients to direct liquid flow in the pipette from the warmer to the cooler.Compared with the previous ones, this way is helpful in decreasing the dead area of controlling through decreasing the viscous rate of DNA liquid, which changes as the temperature varies.The DNA liquid is pushed by a sheer stress at the liquid-pipette interface, which emerges when viscous rate of the liquid changes.Preliminary experimenting results show the efficiency and convenience of this way in improving the system's characteristics.

  12. Cyber Incidents Involving Control Systems

    Energy Technology Data Exchange (ETDEWEB)

    Robert J. Turk

    2005-10-01

    The Analysis Function of the US-CERT Control Systems Security Center (CSSC) at the Idaho National Laboratory (INL) has prepared this report to document cyber security incidents for use by the CSSC. The description and analysis of incidents reported herein support three CSSC tasks: establishing a business case; increasing security awareness and private and corporate participation related to enhanced cyber security of control systems; and providing informational material to support model development and prioritize activities for CSSC. The stated mission of CSSC is to reduce vulnerability of critical infrastructure to cyber attack on control systems. As stated in the Incident Management Tool Requirements (August 2005) ''Vulnerability reduction is promoted by risk analysis that tracks actual risk, emphasizes high risk, determines risk reduction as a function of countermeasures, tracks increase of risk due to external influence, and measures success of the vulnerability reduction program''. Process control and Supervisory Control and Data Acquisition (SCADA) systems, with their reliance on proprietary networks and hardware, have long been considered immune to the network attacks that have wreaked so much havoc on corporate information systems. New research indicates this confidence is misplaced--the move to open standards such as Ethernet, Transmission Control Protocol/Internet Protocol, and Web technologies is allowing hackers to take advantage of the control industry's unawareness. Much of the available information about cyber incidents represents a characterization as opposed to an analysis of events. The lack of good analyses reflects an overall weakness in reporting requirements as well as the fact that to date there have been very few serious cyber attacks on control systems. Most companies prefer not to share cyber attack incident data because of potential financial repercussions. Uniform reporting requirements will do much to make this

  13. Control for a class of hybrid systems

    NARCIS (Netherlands)

    J.H. van Schuppen (Jan)

    1997-01-01

    textabstractA hybrid control system is a control theoretic model for a computer controlled engineering system. A definition of a hybrid control system is formulated that consists of a product of a finite state automaton and of a family of continuous control systems. An example of a transportation

  14. Encyclopedia of systems and control

    CERN Document Server

    Samad, Tariq

    2015-01-01

    The Encyclopedia of Systems and Control collects a broad range of short expository articles that describe the current state of the art in the central topics of control and systems engineering as well as in many of the related fields in which control is an enabling technology. The editors have assembled the most comprehensive reference possible, and this has been greatly facilitated by the publisher’s commitment continuously to publish updates to the articles as they become available in the future. Although control engineering is now a mature discipline, it remains an area in which there is a great deal of research activity, and as new developments in both theory and applications become available, they will be included in the online version of the encyclopedia. A carefully chosen team of leading authorities in the field has written the well over 200 articles that comprise the work. The topics range from basic principles of feedback in servomechanisms to advanced topics such as the control of Boolean networks...

  15. Robust lyapunov controller for uncertain systems

    KAUST Repository

    Laleg-Kirati, Taous-Meriem

    2017-02-23

    Various examples of systems and methods are provided for Lyapunov control for uncertain systems. In one example, a system includes a process plant and a robust Lyapunov controller configured to control an input of the process plant. The robust Lyapunov controller includes an inner closed loop Lyapunov controller and an outer closed loop error stabilizer. In another example, a method includes monitoring a system output of a process plant; generating an estimated system control input based upon a defined output reference; generating a system control input using the estimated system control input and a compensation term; and adjusting the process plant based upon the system control input to force the system output to track the defined output reference. An inner closed loop Lyapunov controller can generate the estimated system control input and an outer closed loop error stabilizer can generate the system control input.

  16. Application of energy-saving technology system of the oil well liquid level continuous monitoring and interrupted control system%油井液面连续监测及间开控制节能技术系统的应用

    Institute of Scientific and Technical Information of China (English)

    朱益飞

    2015-01-01

    This paper introduces the system components, the acoustic level monitoring principle, main technical parameters, oil EMC measures, and the implementation of project application. The comprehensive benefits of the project are analyzed and evaluated. Practice has proved that the oil well liquid level continuous moni⁃toring and control system is a kind of energy⁃saving technology combined with EMC can resolve not only difficult problems in ener⁃gy⁃saving and emissions reduction effectively with funds and tech⁃nology, promote energy⁃saving and emissions reduction of oil field enterprises, but also create an internal energy professional market for oil field enterprises, promote the innovation of energy manage⁃ment mechanism.%介绍油井液面连续监测及间开控制节能技术的系统组成、次声波液位监测原理、主要技术参数、油田合同能源管理配套措施以及项目现场应用实施情况,并对项目综合效益进行了分析评价。实践证明,应用油井液面连续监测及间开控制节能技术结合合同能源管理创新模式实施油田节能技术项目改造,不仅能有效解决油田企业在节能减排方面存在的资金和技术不足的难题,促进油田企业节能减排,而且有利于营造油田企业内部节能专业市场,促进能源管理机制创新。

  17. Multiagent voltage and reactive power control system

    Directory of Open Access Journals (Sweden)

    I. Arkhipov

    2014-12-01

    Full Text Available This paper is devoted to the research of multiagent voltage and reactive power control system development. The prototype of the system has been developed by R&D Center at FGC UES (Russia. The control system architecture is based on the innovative multiagent system theory application that leads to the achievement of several significant advantages (in comparison to traditional control systems implementation such as control system efficiency enhancement, control system survivability and cyber security.

  18. Isolation contactor state control system

    Energy Technology Data Exchange (ETDEWEB)

    Bissontz, Jay E.

    2017-05-16

    A controller area network (CAN) installed on a hybrid electric vehicle provides one node with control of high voltage power distribution system isolation contactors and the capacity to energize a secondary electro-mechanical relay device. The output of the secondary relay provides a redundant and persistent backup signal to the output of the node. The secondary relay is relatively immune to CAN message traffic interruptions and, as a result, the high voltage isolation contactor(s) are less likely to transition open in the event that the intelligent output driver should fail.

  19. Ionic liquid and nanoparticle hybrid systems: Emerging applications.

    Science.gov (United States)

    He, Zhiqi; Alexandridis, Paschalis

    2017-06-01

    Having novel electronic and optical properties that emanate from their nano-scale dimensions, nanoparticles are central to numerous applications. Ionic liquids can confer to nanoparticle chemical protection and physicochemical property enhancement through intermolecular interactions and can consequently improve the stability and reusability of nanoparticle for various operations. With an aim to combine the novel properties of nanoparticles and ionic liquids, different structures have been generated, based on a balance of several intermolecular interactions. Such ionic liquid and nanoparticle hybrids are showing great potential in diverse applications. In this review, we first introduce various types of ionic liquid and nanoparticle hybrids, including nanoparticle colloidal dispersions in ionic liquids, ionic liquid-grafted nanoparticles, and nanoparticle-stabilized ionic liquid-based emulsions. Such hybrid materials exhibit interesting synergisms. We then highlight representative applications of ionic liquid and nanoparticle hybrids in the catalysis, electrochemistry and separations fields. Such hybrids can attain better stability and higher efficiency under a broad range of conditions. Novel and enhanced performance can be achieved in these applications by combining desired properties of ionic liquids and of nanoparticles within an appropriate hybrid nanostructure. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Microprocessor controlled portable TLD system

    Science.gov (United States)

    Apathy, I.; Deme, S.; Feher, I.

    1996-01-01

    An up-to-date microprocessor controlled thermoluminescence dosemeter (TLD) system for environmental and space dose measurements has been developed. The earlier version of the portable TLD system, Pille, was successfully used on Soviet orbital stations as well as on the US Space Shuttle, and for environmental monitoring. The new portable TLD system, Pille'95, consists of a reader and TL bulb dosemeters, and each dosemeter is provided with an EEPROM chip for automatic identification. The glow curve data are digitised and analysed by the program of the reader. The measured data and the identification number appear on the LED display of the reader. Up to several thousand measured data together with the glow curves can be stored on a removable flash memory card. The whole system is supplied either from built-in rechargeable batteries or from the mains of the space station.

  1. 900-L liquid xenon cryogenic system operation for the MEG experiment

    CERN Document Server

    Haruyama, T; Mihara, S; Hisamatsu, Y; Iawamoto, W; Mori, T; Nishiguchi, H; Otani, W; Sawada, R; Uchiyama, Y; Nishitani, T

    2009-01-01

    A cryogenic system for the MEG (muon rare decay) experiment has started operation at the Paul Sherrer Institute in Zurich. The main part of the MEG detector is the 900-L liquid xenon calorimeter for gamma ray detection, equipped with 850 photo multipliers directly immersed in liquid xenon. A 200 W pulse tube cryocooler enabled LN2-free operation of this calorimeter. A liquid purification system; using a liquid pump and a zero boil-off 1000-L cryogenic buffer dewar is also included in the system. The first entire engineering run was carried out in November-December 2007 and satisfactory cryogenic performances were confirmed.

  2. Stress Testing Liquidity Risk: The Case of the Brazilian Banking System.

    OpenAIRE

    Benjamin M. Tabak; Solange M. Guerra; Rodrigo C. Miranda; Sergio Rubens S. de Souza

    2012-01-01

    This paper discusses the effects of the recent financial crisis on the Brazilian banking system. It discusses how liquidity risks have risen during the crisis and preventive measures that were taken in order to cope with these risks. It presents the liquidity stress testing approach that is under use in the Central Bank of Brazil and results from a survey on liquidity stress testing that has been applied to banks that operate in the Brazilian banking system.

  3. Design and implementation of an automated liquid-phase microextraction-chip system coupled on-line with high performance liquid chromatography.

    Science.gov (United States)

    Li, Bin; Petersen, Nickolaj Jacob; Payán, María D Ramos; Hansen, Steen Honoré; Pedersen-Bjergaard, Stig

    2014-03-01

    An automated liquid-phase microextraction (LPME) device in a chip format has been developed and coupled directly to high performance liquid chromatography (HPLC). A 10-port 2-position switching valve was used to hyphenate the LPME-chip with the HPLC autosampler, and to collect the extracted analytes, which then were delivered to the HPLC column. The LPME-chip-HPLC system was completely automated and controlled by the software of the HPLC instrument. The performance of this system was demonstrated with five alkaloids i.e. morphine, codeine, thebaine, papaverine, and noscapine as model analytes. The composition of the supported liquid membrane (SLM) and carrier was optimized in order to achieve reasonable extraction performance of all the five alkaloids. With 1-octanol as SLM solvent and with 25 mM sodium octanoate as anionic carrier, extraction recoveries for the different opium alkaloids ranged between 17% and 45%. The extraction provided high selectivity, and no interfering peaks in the chromatograms were observed when applied to human urine samples spiked with alkaloids. The detection limits using UV-detection were in the range of 1-21 ng/mL for the five opium alkaloids presented in water samples. The repeatability was within 5.0-10.8% (RSD). The membrane liquid in the LPME-chip was regenerated automatically between every third injection. With this procedure the liquid membrane in the LPME-chip was stable in 3-7 days depending on the complexity of sample solutions with continuous operation. With this LPME-chip-HPLC system, series of samples were automatically injected, extracted, separated, and detected without any operator interaction.

  4. Controls and Machine Protection Systems

    CERN Document Server

    Carrone, E

    2016-01-01

    Machine protection, as part of accelerator control systems, can be managed with a 'functional safety' approach, which takes into account product life cycle, processes, quality, industrial standards and cybersafety. This paper will discuss strategies to manage such complexity and the related risks, with particular attention to fail-safe design and safety integrity levels, software and hardware standards, testing, and verification philosophy. It will also discuss an implementation of a machine protection system at the SLAC National Accelerator Laboratory's Linac Coherent Light Source (LCLS).

  5. Investigation and development of liquid-liquid extraction systems for the removal of pertechnetate from aqueous nuclear waste stream simulants

    Science.gov (United States)

    Gansle, Kristina Marie Rohal

    1998-11-01

    The solvent extraction behavior of perrhenate (ReO 4-) and pertechnetate (TcO4- ) from aqueous nuclear waste stream simulants was examined using the anion-exchange reagent Aliquat-336 nitrate. The extraction tendencies of ReO 4- followed those of TcO4- from both acidic and basic media, demonstrating that ReO4 - was a suitable nonradioactive surrogate for TcO4 -. For ICP-AES analysis of Re in high salt solutions, a V-groove nebulizer and 1:1 dilution of the sample and standards with 0.1% Triton X-100 surfactant reduced deposition of solids within the sample introduction system, thus minimizing memory effects. A new approach to waste remediation technology, Redox-Recyclable Extraction and Recovery (R2ER), was also studied. The redox-active species 1,1',3,3'-tetrakis(2-methyl-2-hexyl)ferrocene (HEP) was oxidized to its cationic form for extraction of TcO4 - or ReO4- from aqueous waste and reduced to its neutral form for recovery of the anion. The thermodynamics of liquid-liquid interfacial electron transfer for the oxidation/activation of HEP were shown to be controlled by three factors: the reduction potentials of the redox-active species in the aqueous and organic phases and the transfer of an ion across the liquid-liquid interface. The deactivation/reduction rate of HEP+NO3- by iron was affected by organic solvent diluent and improved by treating the iron with hexanes and 1 M HCl. The volume of solid secondary-waste in the R2ER cycle was reduced by a factor of 3000. In complete extraction/recovery cycles, HEP+NO3- in 2-nonanone removed greater than 99% TcO4- from the 101-SY, 103-SY, 1 M HCl and 1 M NaOH/1.5 M NaNO3 Hanford Tank waste simulants. Another redox-active extractant, bis(hydridotris(1-pyrazolyl)borato)iron(III) nitrate (FeTp2+NO3-), was also selective for ReO4- remediation from simulated aqueous waste. Organic solutions of the alkyl substituted ferricenium extractants were not stable in the presence of nucleophilic anions and/or reducing agents. HEP+NO3

  6. Aqueous biphasic systems involving alkylsulfate-based ionic liquids

    Energy Technology Data Exchange (ETDEWEB)

    Deive, Francisco J. [Instituto de Tecnologia Quimica e Biologica, UNL, Av. Republica, Apartado 127, 2780-901 Oeiras (Portugal); Department of Chemical Engineering, University of Vigo, P.O. Box 36310, Vigo (Spain); Rodriguez, Ana [Department of Chemical Engineering, University of Vigo, P.O. Box 36310, Vigo (Spain); Marrucho, Isabel M., E-mail: imarrucho@itqb.unl.pt [Instituto de Tecnologia Quimica e Biologica, UNL, Av. Republica, Apartado 127, 2780-901 Oeiras (Portugal); Rebelo, Luis P.N. [Instituto de Tecnologia Quimica e Biologica, UNL, Av. Republica, Apartado 127, 2780-901 Oeiras (Portugal)

    2011-11-15

    Highlights: > K{sub 3}PO{sub 4}, K{sub 2}CO{sub 3}, Na{sub 2}CO{sub 3}, and (NH{sub 4}){sub 2}SO{sub 4} act as phase promoter in aqueous solutions of ILs. > Remarkable influence of alkyl-chain length on solubility curves of alkylsulfate-based ILs. > Merchuck correlation was used for describing these systems. > {Delta}S{sub hyd} and Hofmeister series were used to discuss the different salting out effects. - Abstract: The specific effects of K{sub 3}PO{sub 4}, K{sub 2}CO{sub 3}, Na{sub 2}CO{sub 3}, and (NH{sub 4}){sub 2}SO{sub 4}, as high charge-density inorganic salts and thus inducers of the formation of aqueous biphasic systems (ABS) containing several ethyl-methylimidazolium alkylsulfate ionic liquids, C{sub 2}MIM C{sub n}SO{sub 4} (n = 2, 4, 6, or 8), have been assessed at T = 298.15 K. The results are analyzed in the light of the Hofmeister series. The influence of different alkyl chain lengths in the anion, together with the ability of the selected inorganic salts to induce the formation of ABS, is discussed. Phase diagrams have been determined through turbidimetry, including tie lines assignments from mass phase ratios according to the lever - arm rule. The Merchuck equation was satisfactorily used to correlate the solubility curve.

  7. Microfluidic liquid chromatography system for proteomic applications and biomarker screening.

    Science.gov (United States)

    Lazar, Iulia M; Trisiripisal, Phichet; Sarvaiya, Hetal A

    2006-08-01

    A microfluidic liquid chromatography (LC) system for proteomic investigations that integrates all the necessary components for stand-alone operation, i.e., pump, valve, separation column, and electrospray interface, is described in this paper. The overall size of the LC device is small enough to enable the integration of two fully functional separation systems on a 3 in. x 1 in. glass microchip. A multichannel architecture that uses electroosmotic pumping principles provides the necessary functionality for eluent propulsion and sample valving. The flow rates generated within these chips are fully consistent with the requirements of nano-LC platforms that are routinely used in proteomic applications. The microfluidic device was evaluated for the analysis of a protein digest obtained from the MCF7 breast cancer cell line. The cytosolic protein extract was processed according to a shotgun protocol, and after tryptic digestion and prefractionation using strong cation exchange chromatography (SCX), selected sample subfractions were analyzed with conventional and microfluidic LC platforms. Using similar experimental conditions, the performance of the microchip LC was comparable to that obtained with benchtop instrumentation, providing an overlap of 75% in proteins that were identified by more than two unique peptides. The microfluidic LC analysis of a protein-rich SCX fraction enabled the confident identification of 77 proteins by using conventional data filtering parameters, of 39 proteins with p screening applications.

  8. EXPLORING ENGINEERING CONTROL THROUGH PROCESS MANIPULATION OF RADIOACTIVE LIQUID WASTE TANK CHEMICAL CLEANING

    Energy Technology Data Exchange (ETDEWEB)

    Brown, A.

    2014-04-27

    One method of remediating legacy liquid radioactive waste produced during the cold war, is aggressive in-tank chemical cleaning. Chemical cleaning has successfully reduced the curie content of residual waste heels in large underground storage tanks; however this process generates significant chemical hazards. Mercury is often the bounding hazard due to its extensive use in the separations process that produced the waste. This paper explores how variations in controllable process factors, tank level and temperature, may be manipulated to reduce the hazard potential related to mercury vapor generation. When compared using a multivariate regression analysis, findings indicated that there was a significant relationship between both tank level (p value of 1.65x10{sup -23}) and temperature (p value of 6.39x10{sup -6}) to the mercury vapor concentration in the tank ventilation system. Tank temperature showed the most promise as a controllable parameter for future tank cleaning endeavors. Despite statistically significant relationships, there may not be confidence in the ability to control accident scenarios to below mercury’s IDLH or PAC-III levels for future cleaning initiatives.

  9. Characterization of proacrosin/acrosin system after liquid storage and cryopreservation of turkey semen (Meleagris gallopavo).

    Science.gov (United States)

    Słowińska, M; Liszewska, E; Dietrich, G J; Ciereszko, A

    2012-09-15

    freezing-thawing, additional bands appeared in sperm extract and seminal plasma. These bands were of different molecular weight regarding the presence or absence of NPGB. These data suggest that the mechanism of damage to the proacrosin/acrosin system is different for liquid storage and cryopreservation. Liquid storage seems to increase in the susceptibility of the proacrosin/acrosin system to be activated during extraction. Kazal inhibitors of turkey seminal plasma are involved in the control of proacrosin activation. The disturbances of the proacrosin/acrosin system of turkey spermatozoa can be related to a disturbance in the induction of the acrosome reaction. Our results may be important for a better understanding of the proacrosin/acrosin system of turkey spermatozoa and disturbance to this system during liquid storage and cryopreservation.

  10. Autonomous grain combine control system

    Science.gov (United States)

    Hoskinson, Reed L.; Kenney, Kevin L.; Lucas, James R.; Prickel, Marvin A.

    2013-06-25

    A system for controlling a grain combine having a rotor/cylinder, a sieve, a fan, a concave, a feeder, a header, an engine, and a control system. The feeder of the grain combine is engaged and the header is lowered. A separator loss target, engine load target, and a sieve loss target are selected. Grain is harvested with the lowered header passing the grain through the engaged feeder. Separator loss, sieve loss, engine load and ground speed of the grain combine are continuously monitored during the harvesting. If the monitored separator loss exceeds the selected separator loss target, the speed of the rotor/cylinder, the concave setting, the engine load target, or a combination thereof is adjusted. If the monitored sieve loss exceeds the selected sieve loss target, the speed of the fan, the size of the sieve openings, or the engine load target is adjusted.

  11. Thermal Integration of a Liquid Acquisition Device into a Cryogenic Feed System

    Science.gov (United States)

    Hastings, L. J.; Bolshinskiy, L. G.; Schunk, R. G.; Martin, A. K.; Eskridge, R. H.; Frenkel, A.; Grayson, G.; Pendleton, M. L.

    2011-01-01

    Primary objectives of this effort were to define the following: (1) Approaches for quantification of the accumulation of thermal energy within a capillary screen liquid acquisition device (LAD) for a lunar lander upper stage during periods of up to 210 days on the lunar surface, (2) techniques for mitigating heat entrapment, and (3) perform initial testing, data evaluation. The technical effort was divided into the following categories: (1) Detailed thermal modeling of the LAD/feed system interactions using both COMSOL computational fluid device and standard codes, (2) FLOW-3D modeling of bulk liquid to provide interfacing conditions for the LAD thermal modeling, (3) condensation conditioning of capillary screens to stabilize surface tension retention capability, and (4) subscale testing of an integrated LAD/feed system. Substantial progress was achieved in the following technical areas: (1) Thermal modeling and experimental approaches for evaluating integrated cryogen LAD/feed systems, at both the system and component levels, (2) reduced gravity pressure control analyses, (3) analytical modeling and testing for capillary screen conditioning using condensation and wicking, and (4) development of rapid turnaround testing techniques for evaluating LAD/feed system thermal and fluid integration. A comprehensive effort, participants included a diverse cross section of representatives from academia, contractors, and multiple Marshall Space Flight Center organizations.

  12. Control Systems for Logistics Performance

    OpenAIRE

    Virolainen, V.-M.

    1991-01-01

    This text is concerned with identifying and outlining the various aspects of logistics control and performance measurement process. The objective is to identify, based on available literature, methods and techniques which can be used to measure the performance of logistics. Logistics management is essentially a task of balancing between minimizing cost and ensuring availability objectives. Availability can be seen as the output of logistics system. On the input side, management is concer...

  13. Learning System Center App Controller

    CERN Document Server

    Naeem, Nasir

    2015-01-01

    This book is intended for IT professionals working with Hyper-V, Azure cloud, VMM, and private cloud technologies who are looking for a quick way to get up and running with System Center 2012 R2 App Controller. To get the most out of this book, you should be familiar with Microsoft Hyper-V technology. Knowledge of Virtual Machine Manager is helpful but not mandatory.

  14. Control Systems for Logistics Performance

    OpenAIRE

    Virolainen, V.-M.

    1991-01-01

    This text is concerned with identifying and outlining the various aspects of logistics control and performance measurement process. The objective is to identify, based on available literature, methods and techniques which can be used to measure the performance of logistics. Logistics management is essentially a task of balancing between minimizing cost and ensuring availability objectives. Availability can be seen as the output of logistics system. On the input side, management is concer...

  15. Thermodynamic modeling of ternary and quaternary (liquid + liquid) systems containing water, FeCl3, HCl and diisopropyl ether

    NARCIS (Netherlands)

    Milosevic, M.; Hendriks, I.; Smits, R.E.R.; Schuur, Boelo; de Haan, A.B.

    2013-01-01

    Liquid–liquid extraction using ethers as solvents is a potentially energy saving alternative for the concentration of aqueous ferric chloride solutions. Adequate thermodynamic models that describe the behavior of the resulting quaternary systems (FeCl3, ether, acid and water) are not available in

  16. Semantic Linkage of Control Systems

    Directory of Open Access Journals (Sweden)

    Rolf Andreas Rasenack

    2006-01-01

    Full Text Available Control systems are sets of interconnected hardware and software components which regulate the behaviour of processes. The software of modern control systems rises for some years by requirements regarding the flexibility and functionality. Thus the force of innovation grows on enterprises, since ever newer products in ever shorter time intervals must be made available. Associated hereby is the crucial shortening of the product life cycle, whose effects show up in reduced care of the software and the spares inventory. The aim, the concept presented here and developed in a modeling environment, is proved and ensures a minimum functionality of software components. Replacing software components of a control system verified for functionality by a framework at run-time and if necessary the software conditions will become adapted. Quintessential point of this implementation is the usage of an abstract syntax tree. Within its hierarchical structure meta information is attached to nodes and processed by the framework. With the development of the concept for semantic proving of software components the lifetime of software-based products is increased.

  17. Nonlinear modeling and control of slosh in liquid container transfer via a PPR robot

    Science.gov (United States)

    Reyhanoglu, Mahmut; Rubio Hervas, Jaime

    2013-06-01

    This paper studies the point-to-point liquid container transfer control problem for a PPR robot. The robot manipulator is represented as three rigid links, and the liquid slosh dynamics are included using a multi-mass-spring model. It is assumed that two forces and a torque applied to the prismatic joints and the revolute joint, respectively, are available as control inputs. The objective is to control the robot end-effector movement while suppressing the sloshing modes. A nonlinear mathematical model that reflects all of these assumptions is first introduced. Then, Lyapunov-based feedback controllers are designed to achieve the control objective. Two cases are considered: partial-state feedback that does not use slosh state information and full-state feedback that uses both robot state and slosh state measurements or estimations. Computer simulations are included to illustrate the effectiveness of the proposed control laws.

  18. 微流控液液萃取-液液波导集成化分析系统%Microfluidic Analysis System Integrated with Liquid-liquid Extraction and Liquid-liquid Waveguide

    Institute of Scientific and Technical Information of China (English)

    姜健; 李盼盼; 马滢雪; 杨春光; 徐章润

    2016-01-01

    A microfluidic analysis system integrated with liquid-liquid extraction and liquid-liquid waveguide detection was explored. Multiphase laminar liquid-liquid extraction was realized using 1-butyl-3-methyl imidazolium bromide ionic liquid/sodium carbonate solution aqueous two-phase system. Liquid-liquid waveguide absorption photometric detection was achieved by the ionic liquid with higher refractive index served as liquid core and the salt aqueous solution with lower refractive index served as liquid cladding. The extraction efficiency for cresol red extraction is more than 93%. The linear range, the relative standard devia-tion and the detection limit for cresol red detection were 0. 01—0. 40 mg/mL, 3. 4%(n=11) and 3. 8μg/mL (3σ) respectively. Extraction separation and liquid-liquid waveguide-based long optical path absorbance detection were integrated in the system, which provided a new strategy for expanding the application of absorbance detection in microfluidic systems.%利用溴化1-丁基-3-甲基咪唑离子液体/碳酸钠溶液双水相体系,实现了多相层流液液萃取.以具有较高折射率的离子液体为液芯,较低折射率的盐溶液为包层,实现了液液波导吸光度检测.据此建立了一种液液萃取与液液波导检测集成化的微流控分析系统.该系统对甲酚红试样的萃取率在93%以上,对甲酚红试样检测的线性范围为0.01~0.40 mg/mL,相对标准偏差为3.4%(n=11),检出限为3.8μg/mL(3σ).该系统将萃取分离与液液波导长光程吸光度检测集成在一起,为拓展吸光度检测在微流控系统中的应用提供了新思路.

  19. Automatic control of human thermal comfort with a liquid-cooled garment

    Science.gov (United States)

    Kuznetz, L. H.

    1977-01-01

    Water cooling in a liquid-cooled garment is used to maintain the thermal comfort of crewmembers during extravehicular activity. The feasibility of a simple control that will operate automatically to maintain the thermal comfort is established. Data on three test subjects are included to support the conclusion that heat balance can be maintained well within allowable medical limits. The controller concept was also successfully demonstrated for ground-based applications and shows potential for any tasks involving the use of liquid-cooled garments.

  20. Coolant and ambient temperature control for chillerless liquid cooled data centers

    Energy Technology Data Exchange (ETDEWEB)

    Chainer, Timothy J.; David, Milnes P.; Iyengar, Madhusudan K.; Parida, Pritish R.; Simons, Robert E.

    2016-02-02

    Cooling control methods include measuring a temperature of air provided to a plurality of nodes by an air-to-liquid heat exchanger, measuring a temperature of at least one component of the plurality of nodes and finding a maximum component temperature across all such nodes, comparing the maximum component temperature to a first and second component threshold and comparing the air temperature to a first and second air threshold, and controlling a proportion of coolant flow and a coolant flow rate to the air-to-liquid heat exchanger and the plurality of nodes based on the comparisons.

  1. Control of Unknown Chaotic Systems Based on Neural Predictive Control

    Institute of Scientific and Technical Information of China (English)

    LI Dong-Mei; WANG Zheng-Ou

    2003-01-01

    We introduce the predictive control into the control of chaotic system and propose a neural networkcontrol algorithm based on predictive control. The proposed control system stabilizes the chaotic motion in an unknownchaotic system onto the desired target trajectory. The proposed algorithm is simple and its convergence speed is muchhigher than existing similar algorithms. The control system can control hyperchaos. We analyze the stability of thecontrol system and prove the convergence property of the neural controller. The theoretic derivation and simulationsdemonstrate the effectiveness of the algorithm.

  2. WORKING LIQUID PRESSURE AND ITS CONTROL IN HYDRAULIC DRAWING PROCESSES OF CUPS

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    A method of setting up a pressure-stroke characteristic of the working liquid in hydraulic drawing is studied. A pressure-stroke characteristic and software for controlling its forming process are also developed. And a set of pressure controlling devices with PLC as a central processor are designed. It can be got from the relevant experiments that the pressure-stroke characteristic is correct and its control for forming process is available.

  3. Modeling of Plasma-Assisted Conversion of Liquid Ethanol into Hydrogen Enriched Syngas in the Nonequilibrium Electric Discharge Plasma-Liquid System

    CERN Document Server

    Levko, Dmitry; Naumov, Vadim; Chernyak, Valery; Yukhymenko, Vitaly; Prysiazhnevych, Irina; Olszewski, Sergey

    2008-01-01

    In this work we report recent results of our experimental and theoretical studies related to plasma conversion of liquid ethanol into hydrogen-enriched syngas in the plasma-liquid system with the electric discharge in a gas channel with liquid wall using available diagnostics and numerical modeling.

  4. Lyapunov control of quantum systems with impulsive control fields.

    Science.gov (United States)

    Yang, Wei; Sun, Jitao

    2013-01-01

    We investigate the Lyapunov control of finite-dimensional quantum systems with impulsive control fields, where the studied quantum systems are governed by the Schrödinger equation. By three different Lyapunov functions and the invariant principle of impulsive systems, we study the convergence of quantum systems with impulsive control fields and propose new results for the mentioned quantum systems in the form of sufficient conditions. Two numerical simulations are presented to illustrate the effectiveness of the proposed control method.

  5. HTGR Resilient Control System Strategy

    Energy Technology Data Exchange (ETDEWEB)

    Lynne M. Stevens

    2010-09-01

    A preeminent objective for corporate and government organizations is the protection of major investments, which is attained by achieving state awareness, a comprehensive understanding of security and safety, for critical infrastructures. Given the dependence of critical infrastructure on control systems for automation, the integrity of these systems and their ability to provide owner/operators a high degree of state awareness is essential in attaining a high degree of investment protection and public acceptance. Operators as well as government are therefore burdened to ensure they have a timely understanding of the status of their plant or all plants, respectively, to ensure efficient operations and investment and public protection. “This characterization is a significant objective that must consider many aspects of instrumentation, control, and intelligent systems in order to achieve the required result. These aspects include sensory, communication, analysis, decision, and human system interfaces necessary to achieve fusion of data and presentation of results that will provide an understanding of what issues are important and why.

  6. Plug-and-Play Control – Modifying Control Systems Online

    DEFF Research Database (Denmark)

    Bendtsen, Jan Dimon; Trangbæk, K; Stoustrup, Jakob

    2013-01-01

    Often, when new sensor or actuator hardware be- comes available for use in a control system, it is desirable to retain the existing control system and apply the new control capabilities in a gradual fashion rather than decommissioning the entire existing system and replacing it with an altogether...... new control system. However, this requires that the existing controller remains in action, and the new control law component is added to the existing system. This paper formally introduces the concept of Plug-and-Play control and proposes two different methods of introducing new control components...... in a smooth manner, providing stability guarantees during the transition phase as well as retaining the original control structure. The applicability of the methods is illustrated on two different practical example systems, a livestock stable climate control system and a laboratory-scale model of a district...

  7. Research on Web Press Tension Control System

    Directory of Open Access Journals (Sweden)

    Chen Sheng Jiang

    2016-01-01

    Full Text Available Tension control of press is a key and difficult point of the whole machine control. The stand or fall of tension is directly related to the quality of the products. According to the characteristics of the web press tension control, this paper expounds the main factors influencing tension and the purpose of tension control, researches on the tension control principle of web tape, analyzes control rule and control circuit of tension control system, illustrates the advantages of PID control law adopted in the tension control system, and concludes the influencing factors of paper tape tension control system and the corresponding problems needed to solve in the control.

  8. 49 CFR 193.2619 - Control systems.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Control systems. 193.2619 Section 193.2619...: FEDERAL SAFETY STANDARDS Maintenance § 193.2619 Control systems. (a) Each control system must be properly adjusted to operate within design limits. (b) If a control system is out of service for 30 days or more,...

  9. 14 CFR 25.395 - Control system.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Control system. 25.395 Section 25.395... STANDARDS: TRANSPORT CATEGORY AIRPLANES Structure Control Surface and System Loads § 25.395 Control system. (a) Longitudinal, lateral, directional, and drag control system and their supporting structures...

  10. Stochastic stabilization analysis of networked control systems

    Institute of Scientific and Technical Information of China (English)

    Ma Changlin; Fang Huajing

    2007-01-01

    Considering the stochastic delay problems existing in networked control systems, a new control mode is proposed for networked control systems whose delay is longer than a sampling period. Under the control mode, the mathematical model of such a system is established. A stochastic stabilization condition for the system is given. The maximum delay can be derived from the stabilization condition.

  11. Investigation on regeneration and energy storage characteristics of a solar liquid desiccant air-conditioning system

    Institute of Scientific and Technical Information of China (English)

    SHI Mingheng; DU Bin; ZHAO Yun

    2007-01-01

    Solar liquid desiccant air-conditioner is a new air-conditioning system in which liquid desiccant can be regenerated by solar energy and energy can be stored in the form of chemical energy in the liquid desiccant.In this paper regeneration and energy storage characteristics were studied theoretically and experimentally.Two criterion equations for heat and mass transfer in the regeneration process were obtained.The main factors that influence the regeneration process were analyzed.A principal solar liquid desiccant air-conditioning system under energy storage operating mode is proposed.

  12. The control system of intelligent wheelchair

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    <正>A control system of intelligent wheelchair based on spce061A and C8051 is introduced in this discourse.It also introduces the theory of the control system,and the design of hardware and software.The control system including the speech control system of SPCE061 and the keyboard control system of C8051.The movement including marching,countermarching,speedup,slowdown,turning left,turning right,uphill and downhill were realized.The speech control system control based on SPCE061A and C8051 is simple,a high ratio of capability to price.The system can be easily realized and enlarged.

  13. Ultrasonic system for continuous washing of textiles in liquid layers.

    Science.gov (United States)

    Gallego-Juarez, Juan A; Riera, Enrique; Acosta, Victor; Rodríguez, Germán; Blanco, Alfonso

    2010-01-01

    The use of ultrasonic energy for washing of textiles has been tried several times without achieving practical development. In fact, the softness of the fibres makes the cavitation to produce small erosion effect and the reticulate structure of the fabric favours the formation of air bubble layers which obstruct wave penetration. In addition, a high proportion of water with respect to the wash load and a certain water degassing is required to assure efficiency and homogeneity in the wash performance. Such requirements have hindered the commercial development of the ultrasonic washing machines for domestic purposes. For specific industrial applications, a great part of these limitations may be overcome. This article deals with a new process in which the fabric is exposed to the ultrasonic field in a flat format. Such process has been implemented at laboratory and at semi-industrial stage by using specially designed power ultrasonic transducers with rectangular plate radiators. The cleaning effect is produced by the intense cavitation field generated by the plate radiator within a thin layer of liquid where the fabric is introduced. The homogeneity of such effect is achieved by the successive exposure of all the fabric areas to the intense acoustic field. In this paper the structure and performance of the developed system are shown.

  14. Crystal growth in a three-phase system: diffusion and liquid-liquid phase separation in lysozyme crystal growth.

    Science.gov (United States)

    Heijna, M C R; van Enckevort, W J P; Vlieg, E

    2007-07-01

    In the phase diagram of the protein hen egg-white lysozyme, a region is present in which the lysozyme solution demixes and forms two liquid phases. In situ observations by optical microscopy show that the dense liquid droplets dissolve when crystals grow in this system. During this process the demixed liquid region retracts from the crystal surface. The spatial distribution of the dense phase droplets present special boundary conditions for Fick's second law for diffusion. In combination with the cylindrical symmetry provided by the kinetically roughened crystals, this system allows for a full numerical analysis. Using experimental data for setting the boundary conditions, a quasi-steady-state solution for the time-dependent concentration profile was shown to be valid. Comparison of kinetically rough growth in a phase separated system and in a nonseparated system shows that the growth kinetics for a three-phase system differs from a two-phase system, in that crystals grow more slowly but the duration of growth is prolonged.

  15. Rapid removal of nitrobenzene in a three-phase ozone loaded system with gas-liquid-liquid

    Science.gov (United States)

    Li, Shiyin; Zhu, Jiangpeng; Wang, Guoxiang; Ni, Lixiao; Zhang, Yong; Green, Christopher T.

    2015-01-01

    This study explores the removal rate of nitrobenzene (NB) using a new gas-liquid-liquid (G-L-L) three-phase ozone loaded system consisting of a gaseous ozone, an aqueous solvent phase, and a fluorinated solvent phase (perfluorodecalin, or FDC). The removal rate of NB was quantified in relation to six factors including 1) initial pH, 2) initial NB dosage, 3) gaseous ozone dosage, 4) free radical scavenger, 5) FDC pre-aerated gaseous ozone, and 6) reuse of FDC. The NB removal rate is positively affected by the first three factors. Compared with the conventional gas-liquid (water) (G-L) two-phase ozonation system, the free radical scavenger (tertiary butyl alcohol) has much less influence on the removal rate of NB in the G-L-L system. The FDC loaded ozone acts as an ozone reservoir and serves as the main reactive phase in the G-L-L three-phase system. The reuse of FDC has little influence on the removal rate of NB. These experimental results suggest that the oxidation efficiency of ozonation in the G-L-L three-phase system is better than that in the conventional G-L two-phase system.

  16. A microfluidic two-pump system inspired by liquid feeding in mosquitoes

    Science.gov (United States)

    Marino, Andrew; Goad, Angela; Stremler, Mark; Socha, John; Jung, Sunghwan

    Mosquitoes feed on nectar and blood using a two-pump system in the head-a smaller cibarial pump in line with a larger a pharyngeal pump, with a valve in between. To suck, mosquitoes transport the liquid (which may be a multi-component viscous fluid, blood) through a long micro-channel, the proboscis. In the engineering realm, microfluidic devices in biomedical applications, such as lab-on-a-chip technology, necessitate implementing a robust pump design to handle clogging and increase flow control compared to a single-pump system. In this talk, we introduce a microfluidic pump design inspired by the mosquito's two-pump system. The pumping performance (flow rate) in presence of impurities (air bubbles, soft clogs) is quantified as a function of phase difference and volume expansion of the pumps, and the elasticity of the valve.

  17. A Standalone Vision Sensing System for Pseudodynamic Testing of Tuned Liquid Column Dampers

    Directory of Open Access Journals (Sweden)

    Kyung-Won Min

    2016-01-01

    Full Text Available Experimental investigation of the tuned liquid column damper (TLCD is a primal factory task prior to its installation at a site and is mainly undertaken by a pseudodynamic test. In this study, a noncontact standalone vision sensing system is developed to replace a series of the conventional sensors installed at the TLCD tested. The fast vision sensing system is based on binary pixel counting of the portion of images steamed in a pseudodynamic test and achieves near real-time measurements of wave height, lateral motion, and control force of the TLCD. The versatile measurements of the system are theoretically and experimentally evaluated through a wide range of lab scale dynamic tests.

  18. A pump driving liquid cooling circuit method for the aperture of an infrared cold optical system

    Science.gov (United States)

    Xie, RongJian

    2017-06-01

    To enhance the optical recognition and wavelength filtering of an infrared cold optical system, some lens need to be maintained within a certain temperature range, which requires specific thermal management of the aperture. A 250K liquid cooling circuit designed for this purpose is introduced, and the experimental results established and operated in a vacuum environmental simulation chamber is carried out and analyzed. A practical cooling power source of radiation cooling equipment is adopted and the sun exposure heat load is imitated by array of planar membrane heaters attached on the specific designed structure of the aperture. Controlling the aperture temperature and improving the optical system performance are proved effective. Numerical optimization of the cooling circuit and simulation of the aperture are performed , and the factors affect the optical system performance in the mean time are also investigated.

  19. Instrumentation, Control, and Intelligent Systems

    Energy Technology Data Exchange (ETDEWEB)

    2005-09-01

    Abundant and affordable energy is required for U.S. economic stability and national security. Advanced nuclear power plants offer the best near-term potential to generate abundant, affordable, and sustainable electricity and hydrogen without appreciable generation of greenhouse gases. To that end, Idaho National Laboratory (INL) has been charged with leading the revitalization of nuclear power in the U.S. The INL vision is to become the preeminent nuclear energy laboratory with synergistic, world-class, multi-program capabilities and partnerships by 2015. The vision focuses on four essential destinations: (1) Be the preeminent internationally-recognized nuclear energy research, development, and demonstration laboratory; (2) Be a major center for national security technology development and demonstration; (3) Be a multi-program national laboratory with world-class capabilities; (4) Foster academic, industry, government, and international collaborations to produce the needed investment, programs, and expertise. Crucial to that effort is the inclusion of research in advanced instrumentation, control, and intelligent systems (ICIS) for use in current and advanced power and energy security systems to enable increased performance, reliability, security, and safety. For nuclear energy plants, ICIS will extend the lifetime of power plant systems, increase performance and power output, and ensure reliable operation within the system's safety margin; for national security applications, ICIS will enable increased protection of our nation's critical infrastructure. In general, ICIS will cost-effectively increase performance for all energy security systems.

  20. PEF and UV combined system for pathogen microorganisms inactivation in liquid food products

    Science.gov (United States)

    Cramariuc, R.; Popa, M.; Tudorache, A.; Brînduşe, E.; Kontek, A.; Mitelut, A.; Fotescu, L.; Cramariuc, B.; Geicu, M.; Nisiparu, L.

    2011-06-01

    Pulsed electrical field (PEF) treatment is a non-thermal food preservation technology based on the use of the electrical field in impulses applied in order to inactivate and control pathogen microorganisms in foods. This technology is highly appreciated for its ability to prolong the shelf life of the treated product without the use of heat and also for its ability to preserve the product's sensory qualities and nutritional value as well as for the microbiological control of the treated products. This paper presents the PEF and UV treatment methods, or a combination between the two, for microbe inactivation in liquid products. The experiments were carried out using yeasts, lactic bacteria and acetic bacteria in the following systems: stand-alone treatments (PEF or UV) or in combination (UV+PEF or PEF+UV). The results of these experiments showed that one can obtain total inactivation of microorganisms using the combined UV+PEF system, thus leading to the possibility of increasing liquid food products quality as compared to the quality obtained using thermal pasteurization.