WorldWideScience

Sample records for liquid chromatography-based radiometric

  1. A high-performance liquid chromatography-based radiometric assay for acyl-CoA:alcohol transacylase from jojoba.

    Science.gov (United States)

    Garver, W S; Kemp, J D; Kuehn, G D

    1992-12-01

    Acyl-CoA:alcohol transacylase catalyzes the final step in the biosynthesis of storage liquid wax esters from acyl-CoA fatty acids and fatty alcohols in a limited number of microbes, algae, and Simmondsia chinensis Link (jojoba). An improved and automated method of enzyme assay for this catalyst from cotyledons of jojoba is described. The assay method uses reversed-phase C18 high performance liquid chromatography (HPLC) to separate the labeled C30:1 liquid wax product, [14C]-dodecanyl-octadecenoate, from the unreacted substrate, [14C]octadecenoyl-CoA (oleyl-CoA), and other components produced from enzymes present in the crude homogenate of jojoba cotyledons, including [14C]-octadecenoic acid (oleic acid) and [14C]octadecenol (oleyol). Methods are also described for microscale chemical synthesis in one vessel of 14C-radiolabeled substrates and products for the transacylase. These labeled reagents are required to confirm the HPLC separations of reaction products. The radioactive components are quantitated using an on-line flow-through scintillation detector enabling sensitive and precise analysis of the reaction products.

  2. Radiometric Determination of Uranium in Natural Waters after Enrichment and Separation by Cation-Exchange and Liquid-Liquid Extraction

    CERN Document Server

    Pashalidis, I

    2003-01-01

    The alpha-radiometric determination of uranium after its pre-concentration from natural water samples using the cation-exchange resin Chelex-100, its selective extraction by tributylphosphate and electrodeposition on stainless steel discs is reported. The validity of the separation procedure and the chemical recoveries were checked by addition of uranium standard solution as well as by tracing with U-232. The average uranium yield was determined to be (97 +- 2) % for the cation-exchange, (95 +- 2) % for the liquid-liquid extraction, and more than 99% for the electrodeposition. Employing high-resolution alpha-spectroscopy, the measured activity of the U-238 and U-234 radioisotopes was found to be of similar magnitude; i.e. ~7 mBq/L and ~35 mBq/L for ground- and seawater samples, respectively. The energy resolution (FWHM) of the alpha-peaks was 22 keV, while the Minimum Detectable Activity (MDA) was estimated to be 1 mBq/L (at the 95% confidence limit).

  3. Rapid determination of trace semicarbazide in flour products by high-performance liquid chromatography based on a nucleophilic substitution reaction.

    Science.gov (United States)

    Wei, Tianfu; Li, Gongke; Zhang, Zhuomin

    2017-05-01

    Semicarbazide, a toxic food contaminant, widely exists in food products and it originates from the thermal degradation of a food additive of azodicarbonamide or a metabolite of nitrofurazone abused in meat specimens. Many previous methods for semicarbazide determination usually required expensive instruments, difficult-to-prepare monoclonal antibodies, and a long operation time. In this study, a high-performance liquid chromatography method was developed for the rapid determination of trace semicarbazide coupling with a nucleophilic substitution reaction firstly using 4-nitrobenzoyl chloride as derivatization reagent. The derivatization reaction was mild at room temperature for 1 min in neutral solution. Then, semicarbazide derivative was separated and quantified by high-performance liquid chromatography with ultraviolet detection under optimal separation conditions at λmax = 261 nm. The proposed method offered the detection limit of 1.8 μg/L and was successfully applied for the rapid determination of trace semicarbazide in flour products. Semicarbazide in positive real samples could be actually found and quantified in the range of 0.47-7.53 mg/kg. The recoveries were 76.6-119% with relative standard deviations of 0.5-9.1% (n = 3). This developed method was rapid, reliable, and convenient for the determination of trace semicarbazide in food. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Optimization and development of a high-performance liquid chromatography-based one-site immunometric assay with chemiluminescence detection

    Energy Technology Data Exchange (ETDEWEB)

    Oates, Matthew R.; Clarke, William; Zimlich, Alden; Hage, David S

    2002-10-11

    Various practical and theoretical considerations were examined in the creation and optimization of a high-performance liquid chromatography (HPLC)-based one-site immunometric assay. This method used an HPLC analyte analog column and post-column chemiluminescence detection. The specific analyte chosen as the model for this study was L-thyroxine (also known as T{sub 4}). In this technique, a sample containing thyroxine was first combined with an excess of anti-T{sub 4} antibody Fab fragments that had earlier been conjugated with chemiluminescent acridinium ester labels. After incubation, the mixture was injected onto a column that contained immobilized T{sub 4}. The amount of thyroxine in the original sample was then determined by measuring the labeled Fab fragments that appeared in the non-retained fraction, or the decrease in excess Fab fragments that were bound to and later eluted from the column. Items considered in creating this assay included the preparation of acridinium ester-labeled Fab fragments, the detection of these fragments with a post-column reactor, and the creation of a suitable immobilized analog column for capturing excess labeled Fab fragments. The final method could measure T{sub 4} in standards at clinically-relevant concentrations and provided a response within 1.5 min of sample injection, following a 20-45 min incubation with the labeled Fab fragments. Possible applications of this method include its use in clinical chemistry and the screening of proteomic or combinatorial libraries.

  5. Facile preparation of organic-silica hybrid monolith for capillary hydrophilic liquid chromatography based on "thiol-ene" click chemistry.

    Science.gov (United States)

    Chen, Ming-Luan; Zhang, Jun; Zhang, Zheng; Yuan, Bi-Feng; Yu, Qiong-Wei; Feng, Yu-Qi

    2013-04-05

    In this work, a one-step approach to facile preparation of organic-inorganic hybrid monoliths was successfully developed. After vinyl-end organic monomers and azobisisobutyronitrile (AIBN) were mixed with hydrolyzed tetramethoxysilane (TMOS) and 3-mercaptopropyltrimethoxysilane (MPTMS), the homogeneous mixture was introduced into a fused-silica capillary for simultaneous polycondensation and "thiol-ene" click reaction to form the organic-silica hybrid monoliths. By employing this strategy, two types of organic-silica hybrid monoliths with positively charged quaternary ammonium and amide groups were prepared, respectively. The functional groups were successfully introduced onto the monoliths during the sol-gel process with "thiol-ene" click reaction, which was demonstrated by ζ-potential assessment, energy dispersive X-ray spectroscopy (EDX), and Fourier transform infrared (FT-IR) spectroscopy. The porous structure of the prepared monolithic columns was examined by scanning electron microscopy (SEM), nitrogen adsorption-desorption measurement, and mercury intrusion porosimetry. These results indicate the prepared organic-silica hybrid monoliths possess homogeneous column bed, large specific surface area, good mechanical stability, and excellent permeability. The prepared monolithic columns were then applied for anion-exchange/hydrophilic interaction liquid chromatography. Different types of analytes, including benzoic acids, inorganic ions, nucleosides, and nucleotides, were well separated with high column efficiency around 80,000-130,000 plates/m. Taken together, we present a facile and universal strategy to prepare organic-silica hybrid monoliths with a variety of organic monomers using one-step approach. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. Radiometric Observations of Supercooled Liquid Water within a Split Front over the Sierra Nevada.

    Science.gov (United States)

    Heggli, Mark F.; Reynolds, David W.

    1985-11-01

    A storm bearing close structural resemblance to a katafront was observed from the ground with microwave radiometry and a vertically pointing Ka-band radar over the Sierra Nevada of California. The onset and duration of supercooled liquid water was determined and matched to a split front model used to describe the synoptic features of a katafront. Results indicate that prior to the passage of the upper front no supercooled liquid water was observed. This portion of the storm provided the deepest cloud and coldest cloud tops. Supercooled liquid water was most prevalent after the upper front passage, and persisted until the suspected surface front passage. The duration of measured supercooled water was 16 hours.This information broadens the knowledge regarding the presence of supercooled liquid water, and thus possible seeding potential, within winter storms so that treatment can be confined to the period of storms amenable to cloud seeding. Future studies may well confirm the ease with which these periods can be predicted on an operational basis in the Sierra Nevada.

  7. Development of a Stationary Phase Optimised Selectivity Liquid Chromatography based screening method for adulterations of food supplements for the treatment of pain.

    Science.gov (United States)

    Deconinck, E; Kamugisha, A; Van Campenhout, P; Courselle, P; De Beer, J O

    2015-06-01

    Illegally adulterated dietary supplements are an increasing problem worldwide. One of the important groups of often adulterated products are the dietary supplements, sold for the treatment of pain. These often contain analgesics, a heterogeneous group of molecules, containing both hydrophilic and hydrophobic compounds. The development of a screening method for these components, especially when mass spectrometric detection is not available, necessitates chromatographic separation, difficult to achieve with traditional chromatographic columns. In this paper Stationary Phase Optimised Selectivity Liquid Chromatography was used for the development of a screening method for nine analgesics, codeine and caffeine, often present in this type of dietary supplements. The method shows a good separation of all the compounds, allowing the screening to be performed with diode array detection and is fully compatible with mass spectrometry. The method was validated for its selectivity following the guidelines as described for the screening of pesticide residues and residues of veterinary medicines in food.

  8. A High-Performance Liquid Chromatography-Based Screening Method for the Analysis of Atrazine, Alachlor, and Ten of Their Transformation Products

    Science.gov (United States)

    Schroyer, B.R.; Capel, P.D.

    1996-01-01

    A high-performance liquid Chromatography (HPLC) method is presented for the for the fast, quantitative analysis of the target analytes in water and in low organic-carbon, sandy soils that are known to be contaminated with the parent herbicides. Speed and ease of sample preparation was prioritized above minimizing detection limits. Soil samples were extracted using 80:20 methanol:water (volume:volume). Water samples (50 ??L) were injected directly into the HPLC without prior preparation. Method quantification limits for soil samples (10 g dry weight) and water samples ranged from 20 to 110 ng/g and from 20 to 110 ??g/L for atrazine and its transformation products and from 80 to 320 ng/g and from 80 to 320 ??g/L for alachlor and its transformation products, respectively.

  9. High-performance liquid chromatography based chemical fingerprint analysis and chemometric approaches for the identification and distinction of three endangered Panax plants in Southeast Asia.

    Science.gov (United States)

    Xia, Pengguo; Bai, Zhenqing; Liang, Tongyao; Yang, Dongfeng; Liang, Zongsuo; Yan, Xijun; Liu, Yan

    2016-10-01

    Among Panax genus, only three endangered species Panax notoginseng, P. vietnamensis, and P. stipuleanatus that have a similar morphology are mainly distributed in Southeast Asia. These three plants are usually misidentified or adulterated. To identify them well, their chemical chromatographic fingerprints were established by an effective high-performance liquid chromatography method. By comparing the chromatograms, the three Panax species could be distinguished easily using the 22 characteristic peaks. Besides, the data of the chromatographic fingerprints aided by chemometric approaches were applied for the identification and investigation the relationship of different samples and species. Using similarity analysis, the chemical components revealed higher similarity between P. vietnamensis and P. stipuleanatus. The results of hierarchical clustering analysis indicated that samples belonging to the same species could be clustered together. The result of principal component analysis was similar with hierarchical clustering analysis and the three principal components accounted for >80.5% of total variability.

  10. Comparison of three development approaches for Stationary Phase Optimised Selectivity Liquid Chromatography based screening methods Part II: A group of structural analogues (PDE-5 inhibitors in food supplements).

    Science.gov (United States)

    Deconinck, E; Ghijs, L; Kamugisha, A; Courselle, P

    2016-02-01

    Three approaches for the development of a screening method to detect adulterated dietary supplements, based on Stationary Phase Optimised Selectivity Liquid Chromatography were compared for their easiness/speed of development and the performance of the optimal method obtained. This comparison was performed for a heterogeneous group of molecules, i.e. slimming agents (Part I) and a group of structural analogues, i.e. PDE-5 inhibitors (Part II). The first approach makes use of primary runs at one isocratic level, the second of primary runs in gradient mode and the third of primary runs at three isocratic levels to calculate the optimal combination of segments of stationary phases. In each approach the selection of the stationary phase was followed by a gradient optimisation. For the PDE-5 inhibitors, the group of structural analogues, only the method obtained with the third approach was able to differentiate between all the molecules in the development set. Although not all molecules are baseline separated, the method allows the identification of the selected adulterants in dietary supplements using only diode array detection. Though, due to the mobile phases used, the method could also be coupled to mass spectrometry. The method was validated for its selectivity following the guidelines as described for the screening of pesticide residues and residues of veterinary medicines in food.

  11. A high-performance liquid chromatography-based assay of glutathione transferase omega 1 supported by glutathione or non-physiological reductants.

    Science.gov (United States)

    Németi, Balázs; Poór, Miklós; Gregus, Zoltán

    2015-01-15

    The unusual glutathione S-transferase GSTO1 reduces, rather than conjugates, endo- and xenobiotics, and its role in diverse cellular processes has been proposed. GSTO1 has been assayed spectrophotometrically by measuring the disappearance of its substrate, S-(4-nitrophenacyl)glutathione (4-NPG), in the presence of 2-mercaptoethanol that regenerates GSTO1 from its mixed disulfide. To assay GSTO1 in rat liver cytosol, we have developed a high-performance liquid chromatography (HPLC)-based procedure with two main advantages: (i) it measures the formation of the 4-NPG reduction product 4-nitroacetophenone, thereby offering improved sensitivity and accuracy, and (ii) it can use glutathione, the physiological reductant of GSTO1, which is impossible to do with the spectrophotometric procedure. Using the new assay, we show that (i) the GSTO1-catalyzed reduction of 4-NPG in rat liver cytosol also yields 1-(4-nitrophenyl)ethanol, whose formation from 4-nitroacetophenone requires NAD(P)H; (ii) the two assays measure comparable activities with 2-mercaptoethanol or tris(2-carboxyethyl)phosphine used as reductant; (iii) the cytosolic reduction of 4-NPG is inhibited by GSTO1 inhibitors (KT53, 5-chloromethylfluorescein diacetate, and zinc), although the inhibitory effect is strikingly influenced by the type of reductant in the assay and by the sequence of reductant and inhibitor addition. Characterization of GSTO1 inhibitors with the improved assay provides better understanding of interaction of these chemicals with the enzyme.

  12. Development of a high-performance liquid chromatography-based assay for carotenoids in human red blood cells: application to clinical studies.

    Science.gov (United States)

    Nakagawa, Kiyotaka; Kiko, Takehiro; Hatade, Keijiro; Asai, Akira; Kimura, Fumiko; Sookwong, Phumon; Tsuduki, Tsuyoshi; Arai, Hiroyuki; Miyazawa, Teruo

    2008-10-01

    Peroxidized phospholipid-mediated cytotoxicity is involved in the pathophysiology of many diseases; for example, there is an abnormal increase of phospholipid hydroperoxides in red blood cells (RBCs) of dementia patients. Dietary carotenoids have gained attention as potent inhibitors of RBC phospholipid hydroperoxidation, thereby making them plausible candidates for preventing disease. However, the occurrence of carotenoids in human RBCs is still unclear. This is in contradistinction to plasma carotenoids, which have been investigated thoroughly for analytical methods as well as biological significance. In this study, we developed a method to analyze RBC carotenoids using high-performance liquid chromatography (HPLC) coupled with ultraviolet (UV) diode array detection (DAD) and atmospheric pressure chemical ionization (APCI) mass spectrometry (MS). Under optimized conditions that included extraction, separation, and detection procedures, six carotenoids (lutein, zeaxanthin, beta-cryptoxanthin, alpha-carotene, beta-carotene, and lycopene) were separated, detected by DAD, and concurrently identified based on APCI/MS and UV spectra profiles when an extract from human RBCs was subjected to HPLC-DAD-APCI/MS. The amounts of carotenoids varied markedly (1.3-70.2 nmol/L packed cells), and polar oxygenated carotenoids (xanthophylls) were predominant in RBCs. The HPLC-DAD-APCI/MS method would be a useful tool for clinical studies for evaluating the bioavailability of RBC carotenoids.

  13. Alaska Radiometric Ages

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — The Alaska Radiometric Age file is a database of radiometric ages of rocks or minerals sampled from Alaska. The data was collected from professional publications...

  14. Quantitative structure-retention relationships of pesticides in reversed-phase high-performance liquid chromatography based on WHIM and GETAWAY molecular descriptors

    Energy Technology Data Exchange (ETDEWEB)

    D' Archivio, Angelo Antonio [Dipartimento di Chimica, Ingegneria Chimica e Materiali, Universita degli Studi di L' Aquila, Via Vetoio, 67010 Coppito, L' Aquila (Italy)], E-mail: darchivi@univaq.it; Maggi, Maria Anna; Mazzeo, Pietro; Ruggieri, Fabrizio [Dipartimento di Chimica, Ingegneria Chimica e Materiali, Universita degli Studi di L' Aquila, Via Vetoio, 67010 Coppito, L' Aquila (Italy)

    2008-11-03

    The ability of the Weighted Holistic Invariant Molecular (WHIM) and GEometry, Topology, and Atom-Weights AssemblY (GETAWAY) descriptors to represent the effect of molecular structure on the retention of pesticides in reversed-phase high-performance liquid chromatography (RP-HPLC) is investigated. To this end, two retention data sets previously collected in water-acetonitrile mobile phase are re-examined. The first data set (data-set-1) consists of retention data of 26 neutral compounds belonging to widely used pesticide classes, collected within the mobile phase composition range 40-65% (v/v) acetonitrile. The second data set (data-set-2) describes retention of phenoxy acid herbicides and structurally related compounds (benzoic acid and phenylacetic acid derivatives), as a whole covering the pK{sub a} range 2.3-4.3, as a function of mobile phase composition, ranging between 30 and 70% (v/v) acetonitrile, and pH, ranging between 2 and 5. For each data set, the mobile phase attributes are combined with WHIM or GETAWAY descriptors into 'mixed' predictive models in order to attempt retention modelling within the whole mobile phase composition range of analytical interest. Six- or seven-dimensional multilinear models, preliminarily selected using a genetic algorithm, were improved using a multi-layer artificial neural network (ANN) learned by back propagation. ANN performance was tested on three molecules not used in the learning stage and by leave-more-out cross validation. The results reveal that while WHIM descriptors seem not adequate to model retention of solutes of data-set-1, GETAWAY descriptors provide a satisfactory retention model. On the other hand WHIM and GETAWAY descriptors applied to data-set-2 provide a similar performance, even if slightly worse as compared with the above case. Accuracy of retention modelling in these cases is comparable or slightly poorer as compared with the results previously obtained by combining quantum chemical

  15. Quantitative structure-retention relationships of pesticides in reversed-phase high-performance liquid chromatography based on WHIM and GETAWAY molecular descriptors.

    Science.gov (United States)

    D'Archivio, Angelo Antonio; Maggi, Maria Anna; Mazzeo, Pietro; Ruggieri, Fabrizio

    2008-11-03

    The ability of the Weighted Holistic Invariant Molecular (WHIM) and GEometry, Topology, and Atom-Weights AssemblY (GETAWAY) descriptors to represent the effect of molecular structure on the retention of pesticides in reversed-phase high-performance liquid chromatography (RP-HPLC) is investigated. To this end, two retention data sets previously collected in water-acetonitrile mobile phase are re-examined. The first data set (data-set-1) consists of retention data of 26 neutral compounds belonging to widely used pesticide classes, collected within the mobile phase composition range 40-65% (v/v) acetonitrile. The second data set (data-set-2) describes retention of phenoxy acid herbicides and structurally related compounds (benzoic acid and phenylacetic acid derivatives), as a whole covering the pK(a) range 2.3-4.3, as a function of mobile phase composition, ranging between 30 and 70% (v/v) acetonitrile, and pH, ranging between 2 and 5. For each data set, the mobile phase attributes are combined with WHIM or GETAWAY descriptors into "mixed" predictive models in order to attempt retention modelling within the whole mobile phase composition range of analytical interest. Six- or seven-dimensional multilinear models, preliminarily selected using a genetic algorithm, were improved using a multi-layer artificial neural network (ANN) learned by back propagation. ANN performance was tested on three molecules not used in the learning stage and by leave-more-out cross validation. The results reveal that while WHIM descriptors seem not adequate to model retention of solutes of data-set-1, GETAWAY descriptors provide a satisfactory retention model. On the other hand WHIM and GETAWAY descriptors applied to data-set-2 provide a similar performance, even if slightly worse as compared with the above case. Accuracy of retention modelling in these cases is comparable or slightly poorer as compared with the results previously obtained by combining quantum chemical descriptors or usual

  16. Determination of CYP4A11-catalyzed lauric acid 12-hydroxylation by high-performance liquid chromatography with radiometric detection.

    Science.gov (United States)

    Crespi, Charles L; Chang, Thomas K H; Waxman, David J

    2006-01-01

    Lauric acid serves as an endogenous substrate for the cytochrome P450 enzyme CYP4A11. A reverse-phase, high-performance liquid chromatography method is described for the quantification of 12-hydroxylauric acid formed enzymatically by incubation of 14C-labeled lauric acid with cDNA-expressed CYP4A11 or human liver microsomes. Analytical separation is achieved using a C18 column and a gradient of 30% acetonitrile and 2 mM perchloric acid to 100% methanol, using a detection scintillation counter. This method is applicable to enzymatic studies for determination of lauric acid 12-hydroxylation activity.

  17. Radiometric Dating Does Work!

    Science.gov (United States)

    Dalrymple, G. Brent

    2000-01-01

    Discusses the accuracy of dating methods and creationist arguments that radiometric dating does not work. Explains the Manson meteorite impact and the Pierre shale, the ages of meteorites, the K-T tektites, and dating the Mount Vesuvius eruption. (Author/YDS)

  18. Photovoltaics radiometric issues and needs

    Energy Technology Data Exchange (ETDEWEB)

    Myers, D.R. [National Renewable Energy Laboratory, Golden, CO (United States)

    1995-11-01

    This paper presents a summary of issues discussed at the photovoltaic radiometric measurements workshop. Topics included radiometric measurements guides, the need for well-defined goals, documentation, calibration checks, accreditation of testing laboratories and methods, the need for less expensive radiometric instrumentation, data correlations, and quality assurance.

  19. Radiometric studies of mycobacterium tuberculosis

    Directory of Open Access Journals (Sweden)

    Edwaldo E. Camargo

    1987-02-01

    Full Text Available An in vitro assay system that included automated radiometric quantification of 14CO2 released as a result of oxidation of 14C- substrates was applied for studying the metabolic activity of M. tuberculosis under various experimental conditions. These experiments included the study of a mtabolic pathways, b detection times for various inoculum sizes, c effect of filtration on reproducibility of results, d influence of stress environment e minimal inhibitory concentrations for isoniazid, streptomycin, ethambutol and rifampin, and f generation times of M. tuberculosis and M. bovis. These organisms were found to metabolize 14C-for-mate, (U-14C acetate, (U-14C glycerol, (1-14C palmitic acid, 1-14C lauric acid, (U-14C L-malic acid, (U-14C D-glucose, and (U-14C D-glucose, but not (1-14C L-glucose, (U-14C glycine, or (U-14C pyruvate to 14CO2. By using either 14C-for-mate, (1-14C palmitic acid, or (1-14C lauric acid, 10(7 organisms/vial could be detected within 24 48 hours and as few as 10 organisms/vial within 16-20 days. Reproducible results could be obtained without filtering the bacterial suspension, provided that the organisms were grown in liquid 7H9 medium with 0.05% polysorbate 80 and homogenized prior to the study. Drugs that block protein synthesis were found to have lower minimal inhibitory concentrations with the radiometric method when compared to the conventional agar dilution method. The mean generation time obtained for M. bovis and different strains of M. tuberculosis with various substrates was 9 ± 1 hours.

  20. First ultraperformance liquid chromatography based strategy for profiling intact proteins in complex matrices: application to the evaluation of the performance of olive ( Olea europaea L.) stone proteins for cultivar fingerprinting.

    Science.gov (United States)

    Esteve, Clara; Del Río, Carmen; Marina, María Luisa; García, María Concepción

    2010-07-28

    There is a clear need for accelerating protein separations by HPLC. Different proposals have been developed including the use of perfusion and monolithic stationary phases. Nevertheless, these stationary phases, in some occasions, do not provide enough efficiency to resolve these large molecules when they are present in complex matrices. Although ultraperformance liquid chromatography (UPLC) columns have been successfully used for the efficient and rapid separation of small molecules, this is the first time these columns were proposed for the separation of intact proteins in a real complex matrix: the olive stone. Two different strategies were employed for the extraction of olive proteins: enzymatic assisted extraction and buffered extraction. Five different columns traditionally employed for the separation of proteins were used, and results were compared with those obtained when using different sub-2 microm particle columns. Separations obtained with sub-2 mum particle columns significantly improved the separations obtained with the other columns. This paper also demonstrates the applicability of protein profiles obtained from the olive stone for the discrimination among olive varieties.

  1. Uncooled radiometric camera performance

    Science.gov (United States)

    Meyer, Bill; Hoelter, T.

    1998-07-01

    Thermal imaging equipment utilizing microbolometer detectors operating at room temperature has found widespread acceptance in both military and commercial applications. Uncooled camera products are becoming effective solutions to applications currently using traditional, photonic infrared sensors. The reduced power consumption and decreased mechanical complexity offered by uncooled cameras have realized highly reliable, low-cost, hand-held instruments. Initially these instruments displayed only relative temperature differences which limited their usefulness in applications such as Thermography. Radiometrically calibrated microbolometer instruments are now available. The ExplorIR Thermography camera leverages the technology developed for Raytheon Systems Company's first production microbolometer imaging camera, the Sentinel. The ExplorIR camera has a demonstrated temperature measurement accuracy of 4 degrees Celsius or 4% of the measured value (whichever is greater) over scene temperatures ranges of minus 20 degrees Celsius to 300 degrees Celsius (minus 20 degrees Celsius to 900 degrees Celsius for extended range models) and camera environmental temperatures of minus 10 degrees Celsius to 40 degrees Celsius. Direct temperature measurement with high resolution video imaging creates some unique challenges when using uncooled detectors. A temperature controlled, field-of-view limiting aperture (cold shield) is not typically included in the small volume dewars used for uncooled detector packages. The lack of a field-of-view shield allows a significant amount of extraneous radiation from the dewar walls and lens body to affect the sensor operation. In addition, the transmission of the Germanium lens elements is a function of ambient temperature. The ExplorIR camera design compensates for these environmental effects while maintaining the accuracy and dynamic range required by today's predictive maintenance and condition monitoring markets.

  2. Radiometric force in dusty plasmas

    CERN Document Server

    Ignatov, A M

    2000-01-01

    A radiofrequency glow discharge plasma, which is polluted with a certain number of dusty grains, is studied. In addition to various dusty plasma phenomena, several specific colloidal effects should be considered. We focus on radiometric forces, which are caused by inhomogeneous temperature distribution. Aside from thermophoresis, the role of temperature distribution in dusty plasmas is an open question. It is shown that inhomogeneous heating of the grain by ion flows results in a new photophoresis like force, which is specific for dusty discharges. This radiometric force can be observable under conditions of recent microgravity experiments.

  3. Radiometric estimation of water vapor content over Brazil

    Science.gov (United States)

    Karmakar, P. K.; Maiti, M.; Sett, S.; Angelis, C. F.; Machado, L. A. T.

    2011-11-01

    A multi-channel microwave radiometre (make: Radiometrics Corporation) is installed at Instituto Nacional de Pesquisas Espaciais-INPE, Brazil (22°S). The radiometric output of two channels of the radiometer in the form of brightness temperature at 23.834 GHz and 30 GHz, initially, were used to find out the ambient water vapor content and the non-precipitable cloud liquid water content. The necessary algorithm was developed for the purpose. The best results were obtained using the hinge frequency 23.834 GHz and 30 GHz pair having an r.m.s. error of only 2.64. The same methodology was then adopted exploiting 23.034 GHz and 30 GHz pair. In that case the r.m.s. error was 3.42. These results were then compared with those obtained over Kolkata (22°N), India, by using 22.234 GHz and 31.4 GHz radiometric data. This work conclusively suggests the use of a frequency should not be at the water vapor resonance line. Instead, while measuring the vapor content for separation of vapor and cloud liquid, one of them should be a few GHz left or right from the resonance line i.e., at 23.834 GHz and the other one should be around 30 GHz.

  4. RADIOMETRIC PROPERTIES OFAGRICULTURAL PERMEABLE COVERINGS

    Directory of Open Access Journals (Sweden)

    Sergio Castellano

    2010-06-01

    Full Text Available Nets are commonly used for agricultural applications. However, only little is known about the radiometric properties of net types and how to influence them. In order to investigate the influence of net construction parameters on their radiometric properties, a set of radiometric tests were performed on 45 types of agricultural nets. Laboratory tests on large size net samples was performed using a large and a small integrating sphere. Open field radiometric test were carried out by means of an experimental set up (120x120x50 cm and a full scale shade house. Small differences (less than 5% occurred between laboratory and open field tests. Results highlighted that the porosity and the mesh size, combined with the colour and secondarily, with the fabric and the kind of threads of the net influenced the shading performance of the net. The colour influenced the spectral distribution of the radiation passing through the net absorbing its complementary colours. Since nets are three-dimensional structures the transmissivity of direct light under different angles of incident of solar radiation changes when installed in the warp or weft direction. Transmissivity could be considered one of the main parameters involved in the agronomic performances of the netting system.

  5. Statistical synthesis of multiantenna ultrawideband radiometric complexes

    Science.gov (United States)

    Volosyuk, V. K.; Kravchenko, V. F.; Pavlikov, V. V.; Pustovoit, V. I.

    2016-04-01

    An optimum signal processing algorithm of radiometric imaging has been synthesized for the first time using multiantenna ultrawideband (UWB) radiometric complexes (RMCs). Radiometric images (RMI) are interpreted physically as intensity depending on the angular coordinates or the spectral radio brightness averaged in the operation frequency band. In accordance with the synthesized algorithm, a structural scheme of ultrawideband radiometric complexes has been developed. An analytical expression for the ambiguity function of radiometric complexes has been obtained. The ambiguity function is modeled in the case of processing narrowband and ultrawideband radiometric signals. As follows from the analysis of the results, new elements of the theory of optimum processing of UWB radiometric signals with the involvement of multielement antenna systems are an important tool in creating highly accurate, biologically and ecologically safe complexes for studying various media and objects.

  6. Airborne microwave radiometric imaging system

    Science.gov (United States)

    Guo, Wei; Li, Futang; Zhang, Zuyin

    1999-09-01

    A dual channel Airborne Microwave Radiometric Imaging system (AMRI) was designed and constructed for regional environment mapping. The system operates at 35GHz, which collects radiation at horizontal and vertical polarized channels. It runs at mechanical conical scanning with 45 degrees incidence angle. Two Cassegrain antennas with 1.5 degrees beamwidth scan the scene alternately and two pseudo- color images of two channels are displayed on the screen of PC in real time. Simultaneously, all parameters of flight and radiometric data are sorted in hard disk for post- processing. The sensitivity of the radiometer (Delta) T equals 0.16K. A new displaying method, unequal size element arc displaying method, is used in image displaying. Several experiments on mobile tower were carried out and the images demonstrate that the AMRI is available to work steadily and accurately.

  7. Radiometric studies of Mycobacterium lepraemurium.

    Science.gov (United States)

    Camargo, E E; Larson, S M; Tepper, B S; Wagner, H N

    1976-01-01

    The radiometric method has been applied for studying the metabolism of M. lepraemurium and the conditions which might force or inhibit its metabolic activity in vitro. These organisms assimilate and oxidize (U-14C) glycerol, and (U-14C) acetate, but are unable to oxidize (U-14C) glucose, (U-14C) pyruvate, (U-14C) glycine and 14C-formate. When incubated at 30 degrees C M. lepraemurium oxidizes (U-14C) acetate to 14CO2 faster than 37 degrees C. The smae effect was observed with increasing concentrations of polysorbate 80 (Tween 80), or the 14C-substrate. No change in metabolic rate was observed when the organisms were kept at -20 degrees C for 12 days. Although tried several times, it was not possible to demonstrate any "inhibitors" of bacterial metabolism in the reaction system. The radiometric method seems to be an important tool for studying metabolic pathways and the influence of physical and biochemical factors on the metabolism of M. lepraemurium in vitro.

  8. Survey of emissivity measurement by radiometric methods.

    Science.gov (United States)

    Honner, M; Honnerová, P

    2015-02-01

    A survey of the state of the art in the field of spectral directional emissivity measurements by using radiometric methods is presented. Individual quantity types such as spectral, band, or total emissivity are defined. Principles of emissivity measurement by various methods (direct and indirect, and calorimetric and radiometric) are discussed. The paper is focused on direct radiometric methods. An overview of experimental setups is provided, including the design of individual parts such as the applied reference sources of radiation, systems of sample clamping and heating, detection systems, methods for the determination of surface temperature, and procedures for emissivity evaluation.

  9. Relative Radiometric Normalization of Multitemporal images

    Directory of Open Access Journals (Sweden)

    Andrés Castillo Sanz

    2010-12-01

    Full Text Available A correct radiometric normalization between both images is fundamental for change detection. MAD method and its IR-MAD extension in an implementation on multisprectral aerial images is described in this paper

  10. Lansat MSS, Radiometric Processing Improvement

    Science.gov (United States)

    Saunier, Sebastien; Salgues, Germain; Gascon, Ferran; Biaasutti, Roberto

    2016-08-01

    The reprocessing campaigns of Landsat European Space Agency (ESA) data archive have been initiated since 3 years [1]. As part of this project, the processing algorithms have been upgraded. This article focuses on the radiometric processing of historical data observed with the Multi Spectral Scanner (MSS) instruments on board Landsat 1, 2, 3, 4 and 5.The Landsat MSS data have been recorded data from 1972 up to 1990. The MSS instruments have been designed with four visible bands covering the near / infrared regions of the electromagnetic spectrum, allowing the spatial sampling of our Earth surface at 60 meter.The current calibration method has shown some limitations in case of data observed out of mid latitude areas, where the Earth surface is bright because of desert or snow. The resulting image data suffers from saturations and is not fit for the potential application purposes.Although, when saturation exist, further investigations have shown that the radiometry of the raw data involved in the production of the Level 1 images is generally correct. As consequences, experiments have been undertaken to adapt the current processing in order to produce image data saturation free products.

  11. Radiometric surveys in underground environment

    Science.gov (United States)

    Bochiolo, Massimo; Chiozzi, Paolo; Verdoya, Massimo; Pasquale, Vincenzo

    2010-05-01

    Due to their ability to travel through the air for several metres, gamma-rays emitted from natural radioactive elements can be successfully used in surveys carried out both with airborne and ground equipments. Besides the concentration of the radio-elements contained in rocks and soils and the intrinsic characteristics of the gamma-ray detector, the detected count rate depends on the solid angle around the spectrometer. On a flat outcrop, ground spectrometry detects the radiation ideally produced by a cylindrical mass of rock of about two metres in diameter and thickness of about half a meter. Under these geometrical conditions, the natural radioactivity can be easily evaluated. With operating conditions different from the standard ones, such as at the edge of an escarpment, the count rate halves because of the missing material, whereas in the vicinity of a rock wall the count rate will increase. In underground environment, the recorded count rate may even double and the in situ assessment of the concentration of radio-elements may be rather difficult, even if the ratios between the different radio-elements may not be affected. We tested the applicability of gamma-ray spectrometry for rapid assessment of the potential hazard levels related to radon and radiation dose rate in underground environment. A mine shaft, located in a zone of uranium enrichment in Liguria (Italy), has been investigated. A preliminary ground radiometric survey was carried out to define the extent of the ore deposit. Then, the radiometric investigation was focussed on the mine shaft. Due to rock mass above the shaft vault, the background gamma radiation can be considered of negligible influence on measurements. In underground surveys, besides deviations from a flat geometry, factors controlling radon exhalation, emanation and stagnation, such as fractures, water leakage and the presence of ventilation, should be carefully examined. We attempted to evaluate these control factors and collected

  12. RADIOMETRIC TECHNIQUES IN HEAVY MINERAL EXPLORATION AND EXPLOITATION

    NARCIS (Netherlands)

    DEMEIJER, RJ; TANCZOS, IC; STAPEL, C

    1994-01-01

    In recent years the Environmental Research Group of the KVI has been developing a number of radiometric techniques that may be employed in mineral sand exploration. These techniques involve: radiometric fingerprinting for assessing sand provenances and mineralogical composition; thermoluminescence

  13. RADIOMETRIC TECHNIQUES IN HEAVY MINERAL EXPLORATION AND EXPLOITATION

    NARCIS (Netherlands)

    DEMEIJER, RJ; TANCZOS, IC; STAPEL, C

    1994-01-01

    In recent years the Environmental Research Group of the KVI has been developing a number of radiometric techniques that may be employed in mineral sand exploration. These techniques involve: radiometric fingerprinting for assessing sand provenances and mineralogical composition; thermoluminescence f

  14. Radiometric Receiver for Passive Microwave Imaging System

    Directory of Open Access Journals (Sweden)

    Ubaichin Anton

    2016-01-01

    Full Text Available The paper describes a new method to develop a zero-type W-band radiometric receiver. The block diagram and operating algorithm of the digital control system are presented. The main advantages of the zero method in passive radio physical investigations in comparison with classical engineering solutions are shown.

  15. Radiometric Correction of Multitemporal Satellite Imagery

    Directory of Open Access Journals (Sweden)

    S. G. Biday,

    2010-01-01

    Full Text Available Problem statement: Repeated observation of a given area over time yields potential for many forms of change detection analysis. These repeated observations are confounded in terms of radiometric consistency due to changes in sensor calibration over time, differences in illumination, observation angles and variation in atmospheric effects. Also major problem with satellite images is that regions below clouds are not covered by sensor. Cloud detection, removal and data prediction in cloudy region is essential for image interpretation. Approach: This study demonstrated applicability of empirical relative radiometric normalization methods to a set of multitemporal cloudy images acquired by Resourcesat-1 LISS III sensor. Objective of this study was to detect and remove cloud cover and normalize an image radiometrically. Cloud detection was achieved by using Average Brightness Threshold (ABT algorithm. The detected cloud removed and replaced with data from another images of the same area. We proposed a new method in which cloudy pixels are replaced with predicted pixel values obtained by regression. After cloud removal, the proposed normalization method was applied to reduce the radiometric influence caused by non surface factors. This process identified landscape elements whose reflectance values are nearly constant over time, i.e., the subset of non-changing pixels are identified using frequency based correlation technique. Further, we proposed another method of radiometric correction in frequency domain, Pseudo-Invariant Feature regression and this process removed landscape elements such as vegetation whose reflectance values are not constant over time. It takes advantage of vegetation being typically high frequency area, can be removed by low pass filter. Results: The quality of radiometric normalization is statistically assessed by R2 value and Root Mean Square Error (RMSE between each pair of analogous band. Further we verified that difference

  16. Radiometric consistency assessment of hyperspectral infrared sounders

    OpenAIRE

    Wang, L.; Y. Han; Jin, X.; Y. Chen; D. A. Tremblay

    2015-01-01

    The radiometric and spectral consistency among the Atmospheric Infrared Sounder (AIRS), the Infrared Atmospheric Sounding Interferometer (IASI), and the Cross-track Infrared Sounder (CrIS) is fundamental for the creation of long-term infrared (IR) hyperspectral radiance benchmark datasets for both inter-calibration and climate-related studies. In this study, the CrIS radiance measurements on Suomi National Polar-orbiting Partnership (SNPP) satellite are directly com...

  17. GEOMETRIC AND RADIOMETRIC EVALUATION OF RASAT IMAGES

    Directory of Open Access Journals (Sweden)

    A. Cam

    2016-06-01

    Full Text Available RASAT, the second remote sensing satellite of Turkey, was designed and assembled, and also is being operated by TÜBİTAK Uzay (Space Technologies Research Institute (Ankara. RASAT images in various levels are available free-of-charge via Gezgin portal for Turkish citizens. In this paper, the images in panchromatic (7.5 m GSD and RGB (15 m GSD bands in various levels were investigated with respect to its geometric and radiometric characteristics. The first geometric analysis is the estimation of the effective GSD as less than 1 pixel for radiometrically processed level (L1R of both panchromatic and RGB images. Secondly, 2D georeferencing accuracy is estimated by various non-physical transformation models (similarity, 2D affine, polynomial, affine projection, projective, DLT and GCP based RFM reaching sub-pixel accuracy using minimum 39 and maximum 52 GCPs. The radiometric characteristics are also investigated for 8 bits, estimating SNR between 21.8-42.2, and noise 0.0-3.5 for panchromatic and MS images for L1R when the sea is masked to obtain the results for land areas. The analysis show that RASAT images satisfies requirements for various applications. The research is carried out in Zonguldak test site which is mountainous and partly covered by dense forest and urban areas.

  18. Revised landsat-5 thematic mapper radiometric calibration

    Science.gov (United States)

    Chander, G.; Markham, B.L.; Barsi, J.A.

    2007-01-01

    Effective April 2, 2007, the radiometric calibration of Landsat-5 (L5) Thematic Mapper (TM) data that are processed and distributed by the U.S. Geological Survey (USGS) Center for Earth Resources Observation and Science (EROS) will be updated. The lifetime gain model that was implemented on May 5, 2003, for the reflective bands (1-5, 7) will be replaced by a new lifetime radiometric-calibration curve that is derived from the instrument's response to pseudoinvariant desert sites and from cross calibration with the Landsat-7 (L7) Enhanced TM Plus (ETM+). Although this calibration update applies to all archived and future L5 TM data, the principal improvements in the calibration are for the data acquired during the first eight years of the mission (1984-1991), where the changes in the instrument-gain values are as much as 15%. The radiometric scaling coefficients for bands 1 and 2 for approximately the first eight years of the mission have also been changed. Users will need to apply these new coefficients to convert the calibrated data product digital numbers to radiance. The scaling coefficients for the other bands have not changed. ?? 2007 IEEE.

  19. The radiometric characteristics of KOMPSAT-3A by using reference radiometric tarps and ground measurement

    Science.gov (United States)

    Yeom, Jong-Min

    2016-09-01

    In this study, we performed the vicarious radiometric calibration of KOMPSAT-3A multispectral bands by using 6S radiative transfer model, radiometric tarps, MFRSR measurements. Furthermore, to prepare the accurate input parameter, we also did experiment work to measure the BRDF of radiometric tarps based on hyperspectral gonioradiometer to compensate the observation geometry difference between satellite and ASD Fieldspec 3. Also, we measured point spread function (PSF) by using the bright star and corrected multispectral bands based on the Wiener filter. For accurate atmospheric constituent effects such as aerosol optical depth, column water, and total ozone, we used MFRSR instrument and estimated related optical depth of each gases. Based on input parameters for 6S radiative transfer model, we simulated top of atmosphere (TOA) radiance by observed by KOMPSAT-3A and matched-up the digital number. Consequently, DN to radiance coefficients was determined based on aforementioned methods and showed reasonable statistics results.

  20. Rapid radiometric methods to detect and differentiate Mycobacterium tuberculosis/M. bovis from other mycobacterial species

    Energy Technology Data Exchange (ETDEWEB)

    Siddiqi, S.H.; Hwangbo, C.C.; Silcox, V.; Good, R.C.; Snider, D.E. Jr.; Middlebrook, G.

    1984-10-01

    Rapid methods for the differentiation of Mycobacterium tuberculosis/M. bovis (TB complex) from other mycobacteria (MOTT bacilli) were developed and evaluated in a three-phase study. In the first phase, techniques for identification of Mycobacterium species were developed by using radiometric technology and BACTEC Middlebrook 7H12 liquid medium. Based on /sup 14/CO/sub 2/ evolution, characteristic growth patterns were established for 13 commonly encountered mycobacterial species. Mycobacteria belonging to the TB complex were differentiated from other mycobacteria by cellular morphology and rate of /sup 14/CO/sub 2/ evolution. For further differentiation, radiometric tests for niacin production and inhibition by Q-nitro-alpha-acetyl amino-beta-hydroxy-propiophenone (NAP) were developed. In the second phase, 100 coded specimens on Lowenstein-Jensen medium were identified as members of the TB complex, MOTT bacilli, bacteria other than mycobacteria, or ''no viable organisms'' within 3 to 12 (average 6.4) days of receipt from the Centers for Disease Control. Isolation and identification of mycobacteria from 20 simulated sputum specimens were carried out in phase III. Out of 20 sputum specimens, 16 contained culturable mycobacteria, and all of the positives were detected by the BACTEC method in an average of 7.3 days. The positive mycobacterial cultures were isolated and identified as TB complex or MOTT bacilli in an average of 12.8 days. The radiometric NAP test was found to be highly sensitive and specific for a rapid identification of TB complex, whereas the radiometric niacin test was found to have some inherent problems. Radiometric BACTEC and conventional methodologies were in complete agreement in Phase II as well as in Phase III.

  1. INTRABAND RADIOMETRIC PERFORMANCE OF THE LANDSAT 4 THEMATIC MAPPER.

    Science.gov (United States)

    Kieffer, Hugh H.; Eliason, Eric M.; Chavez, Pat S.; ,

    1985-01-01

    This preliminary report examines those radiometric characteristics of the Landsat 4 Thematic Mapper (TM) that can be established without absolute calibration of spectral data. Analysis is based largely on radiometrically raw (B type) data of three daytime and two nighttime scenes; in most scenes, a set of 512 lines were examined on an individual-detector basis. Subscenes selected for uniform-radiance were used to characterize subtle radiometric differences and noise problems.

  2. Radiometric instrumentation and measurements guide for photovoltaic performance testing

    Energy Technology Data Exchange (ETDEWEB)

    Myers, D.

    1997-04-01

    The Photovoltaic Module and Systems Performance and Engineering Project at the National Renewable Energy Laboratory performs indoor and outdoor standardization, testing, and monitoring of the performance of a wide range of photovoltaic (PV) energy conversion devices and systems. The PV Radiometric Measurements and Evaluation Team (PVSRME) within that project is responsible for measurement and characterization of natural and artificial optical radiation which stimulates the PV effect. The PV manufacturing and research and development community often approaches project members for technical information and guidance. A great area of interest is radiometric instrumentation, measurement techniques, and data analysis applied to understanding and improving PV cell, module, and system performance. At the Photovoltaic Radiometric Measurements Workshop conducted by the PVSRME team in July 1995, the need to communicate knowledge of solar and optical radiometric measurements and instrumentation, gained as a result of NREL`s long-term experiences, was identified as an activity that would promote improved measurement processes and measurement quality in the PV research and manufacturing community. The purpose of this document is to address the practical and engineering need to understand optical and solar radiometric instrument performance, selection, calibration, installation, and maintenance applicable to indoor and outdoor radiometric measurements for PV calibration, performance, and testing applications. An introductory section addresses radiometric concepts and definitions. Next, concepts essential to spectral radiometric measurements are discussed. Broadband radiometric instrumentation and measurement concepts are then discussed. Each type of measurement serves as an important component of the PV cell, module, and system performance measurement and characterization process.

  3. Evaluation on Radiometric Capability of Chinese Optical Satellite Sensors

    Science.gov (United States)

    Yang, Aixia; Zhong, Bo; Wu, Shanlong; Liu, Qinhuo

    2017-01-01

    The radiometric capability of on-orbit sensors should be updated on time due to changes induced by space environmental factors and instrument aging. Some sensors, such as Moderate Resolution Imaging Spectroradiometer (MODIS), have onboard calibrators, which enable real-time calibration. However, most Chinese remote sensing satellite sensors lack onboard calibrators. Their radiometric calibrations have been updated once a year based on a vicarious calibration procedure, which has affected the applications of the data. Therefore, a full evaluation of the sensors’ radiometric capabilities is essential before quantitative applications can be made. In this study, a comprehensive procedure for evaluating the radiometric capability of several Chinese optical satellite sensors is proposed. In this procedure, long-term radiometric stability and radiometric accuracy are the two major indicators for radiometric evaluation. The radiometric temporal stability is analyzed by the tendency of long-term top-of-atmosphere (TOA) reflectance variation; the radiometric accuracy is determined by comparison with the TOA reflectance from MODIS after spectrally matching. Three Chinese sensors including the Charge-Coupled Device (CCD) camera onboard Huan Jing 1 satellite (HJ-1), as well as the Visible and Infrared Radiometer (VIRR) and Medium-Resolution Spectral Imager (MERSI) onboard the Feng Yun 3 satellite (FY-3) are evaluated in reflective bands based on this procedure. The results are reasonable, and thus can provide reliable reference for the sensors’ application, and as such will promote the development of Chinese satellite data. PMID:28117745

  4. Absolute Radiometric Calibration of KOMPSAT-3A

    Science.gov (United States)

    Ahn, H. Y.; Shin, D. Y.; Kim, J. S.; Seo, D. C.; Choi, C. U.

    2016-06-01

    This paper presents a vicarious radiometric calibration of the Korea Multi-Purpose Satellite-3A (KOMPSAT-3A) performed by the Korea Aerospace Research Institute (KARI) and the Pukyong National University Remote Sensing Group (PKNU RSG) in 2015.The primary stages of this study are summarized as follows: (1) A field campaign to determine radiometric calibrated target fields was undertaken in Mongolia and South Korea. Surface reflectance data obtained in the campaign were input to a radiative transfer code that predicted at-sensor radiance. Through this process, equations and parameters were derived for the KOMPSAT-3A sensor to enable the conversion of calibrated DN to physical units, such as at-sensor radiance or TOA reflectance. (2) To validate the absolute calibration coefficients for the KOMPSAT-3A sensor, we performed a radiometric validation with a comparison of KOMPSAT-3A and Landsat-8 TOA reflectance using one of the six PICS (Libya 4). Correlations between top-of-atmosphere (TOA) radiances and the spectral band responses of the KOMPSAT-3A sensors at the Zuunmod, Mongolia and Goheung, South Korea sites were significant for multispectral bands. The average difference in TOA reflectance between KOMPSAT-3A and Landsat-8 image over the Libya 4, Libya site in the red-green-blue (RGB) region was under 3%, whereas in the NIR band, the TOA reflectance of KOMPSAT-3A was lower than the that of Landsat-8 due to the difference in the band passes of two sensors. The KOMPSAT-3Aensor includes a band pass near 940 nm that can be strongly absorbed by water vapor and therefore displayed low reflectance. Toovercome this, we need to undertake a detailed analysis using rescale methods, such as the spectral bandwidth adjustment factor.

  5. Landsat-7 ETM+ radiometric calibration status

    Science.gov (United States)

    Barsi, Julia A.; Markham, Brian L.; Czapla-Myers, Jeffrey S.; Helder, Dennis L.; Hook, Simon J.; Schott, John R.; Haque, Md. Obaidul

    2016-09-01

    Now in its 17th year of operation, the Enhanced Thematic Mapper + (ETM+), on board the Landsat-7 satellite, continues to systematically acquire imagery of the Earth to add to the 40+ year archive of Landsat data. Characterization of the ETM+ on-orbit radiometric performance has been on-going since its launch in 1999. The radiometric calibration of the reflective bands is still monitored using on-board calibration devices, though the Pseudo-Invariant Calibration Sites (PICS) method has proven to be an effective tool as well. The calibration gains were updated in April 2013 based primarily on PICS results, which corrected for a change of as much as -0.2%/year degradation in the worst case bands. A new comparison with the SADE database of PICS results indicates no additional degradation in the updated calibration. PICS data are still being tracked though the recent trends are not well understood. The thermal band calibration was updated last in October 2013 based on a continued calibration effort by NASA/Jet Propulsion Lab and Rochester Institute of Technology. The update accounted for a 0.036 W/m2 sr μm or 0.26K at 300K bias error. The updated lifetime trend is now stable to within +/- 0.4K.

  6. The Influence of Colour on Radiometric Performances of Agricultural Nets

    NARCIS (Netherlands)

    Castellano, S.; Hemming, S.; Russo, G.

    2008-01-01

    The whole construction parameters of the net, combined with the shape of the structure, the position of the sun and the sky conditions affect the radiometric performance of the permeable covering system. The radiometric properties of the permeable membrane influence the quality of the agricultural p

  7. The Influence of Colour on Radiometric Performances of Agricultural Nets

    NARCIS (Netherlands)

    Castellano, S.; Hemming, S.; Russo, G.

    2008-01-01

    The whole construction parameters of the net, combined with the shape of the structure, the position of the sun and the sky conditions affect the radiometric performance of the permeable covering system. The radiometric properties of the permeable membrane influence the quality of the agricultural

  8. GIFTS SM EDU Radiometric and Spectral Calibrations

    Science.gov (United States)

    Tian, J.; Reisse, R. a.; Johnson, D. G.; Gazarik, J. J.

    2007-01-01

    The Geosynchronous Imaging Fourier Transform Spectrometer (GIFTS) Sensor Module (SM) Engineering Demonstration Unit (EDU) is a high resolution spectral imager designed to measure infrared (IR) radiance using a Fourier transform spectrometer (FTS). The GIFTS instrument gathers measurements across the long-wave IR (LWIR), short/mid-wave IR (SMWIR), and visible spectral bands. The raw interferogram measurements are radiometrically and spectrally calibrated to produce radiance spectra, which are further processed to obtain atmospheric profiles via retrieval algorithms. This paper describes the processing algorithms involved in the calibration. The calibration procedures can be subdivided into three categories: the pre-calibration stage, the calibration stage, and finally, the post-calibration stage. Detailed derivations for each stage are presented in this paper.

  9. Verification of the radiometric map of the Czech Republic.

    Science.gov (United States)

    Matolín, Milan

    2017-01-01

    The radiometric map of the Czech Republic is based on uniform regional airborne radiometric total count measurements (1957-1959) which covered 100% of the country. The airborne radiometric instrument was calibrated to a (226)Ra point source. The calibration facility for field gamma-ray spectrometers, established in the Czech Republic in 1975, significantly contributed to the subsequent radiometric data standardization. In the 1990's, the original analogue airborne radiometric data were digitized and using the method of back-calibration (IAEA, 2003) converted to dose rate. The map of terrestrial gamma radiation expressed in dose rate (nGy/h) was published on the scale 1:500,000 in 1995. Terrestrial radiation in the Czech Republic, formed by magmatic, sedimentary and metamorphic rocks of Proterozoic to Quaternary age, ranges mostly from 6 to 245 nGy/h, with a mean of 65.6 ± 19.0 nGy/h. The elevated terrestrial radiation in the Czech Republic, in comparison to the global dose rate average of 54 nGy/h, reflects an enhanced content of natural radioactive elements in the rocks. The 1995 published radiometric map of the Czech Republic was successively studied and verified by additional ground gamma-ray spectrometric measurements and by comparison to radiometric maps of Germany, Poland and Slovakia in border zones. A ground dose rate intercomparison measurement under participation of foreign and domestic professional institutions revealed mutual dose rate deviations about 20 nGy/h and more due to differing technical parameters of applied radiometric instruments. Studies and verification of the radiometric map of the Czech Republic illustrate the magnitude of current deviations in dose rate data. This gained experience can assist in harmonization of dose rate data on the European scale.

  10. Improved Absolute Radiometric Calibration of a UHF Airborne Radar

    Science.gov (United States)

    Chapin, Elaine; Hawkins, Brian P.; Harcke, Leif; Hensley, Scott; Lou, Yunling; Michel, Thierry R.; Moreira, Laila; Muellerschoen, Ronald J.; Shimada, Joanne G.; Tham, Kean W.; hide

    2015-01-01

    The AirMOSS airborne SAR operates at UHF and produces fully polarimetric imagery. The AirMOSS radar data are used to produce Root Zone Soil Moisture (RZSM) depth profiles. The absolute radiometric accuracy of the imagery, ideally of better than 0.5 dB, is key to retrieving RZSM, especially in wet soils where the backscatter as a function of soil moisture function tends to flatten out. In this paper we assess the absolute radiometric uncertainty in previously delivered data, describe a method to utilize Built In Test (BIT) data to improve the radiometric calibration, and evaluate the improvement from applying the method.

  11. MISR radiometric camera-by-camera Cloud Mask V004

    Data.gov (United States)

    National Aeronautics and Space Administration — This file contains the Radiometric camera-by-camera Cloud Mask dataset. It is used to determine whether a scene is classified as clear or cloudy. A new parameter has...

  12. Data acquisition and processing - helicopter radiometric survey, Krageroe, 1998

    CERN Document Server

    Beard, L P

    2000-01-01

    On 07 October 1998 a helicopter radiometric survey was flown in the vicinity of Krageroe municipality. The purpose of the survey was to provide radiometric information to help assess radon hazard from radioactive rocks in the area. A total of 60 line-kilometres of radiometric data were acquired in a single flight, covering an area of approximately 3 square km with a 50-m line spacing. The data were collected by Geological Survey of Norway (NGU) personnel and processed at NGU. Radiometric data were reduced using the three-channel procedure recommended by the International Atomic Energy Association. All data were gridded using square cells with 30-m sides and geophysical maps were produced at a scale of 1:5000. This report covers aspects of data acquisition and processing (Author)

  13. Spectral and Radiometric Calibration using Tunable Lasers Project

    Data.gov (United States)

    National Aeronautics and Space Administration —  SIRCUS-based calibration relies on a set of monitoring radiometers and tunable laser sources to provide an absolute radiometric calibration that can approach...

  14. Quantifying the Dynamic Ocean Surface Using Underwater Radiometric Measurement

    Science.gov (United States)

    2013-09-30

    Radiometric Measurement Lian Shen Department of Mechanical Engineering & St. Anthony Falls Laboratory University of Minnesota Minneapolis, MN...information if it does not display a currently valid OMB control number. 1. REPORT DATE 30 SEP 2013 2. REPORT TYPE 3. DATES COVERED 00-00-2013 to 00-00...2013 4. TITLE AND SUBTITLE Quantifying the Dynamic Ocean Surface Using Underwater Radiometric Measurement 5a. CONTRACT NUMBER 5b. GRANT NUMBER

  15. The Radiometric Bode's Law and Extrasolar Planets

    CERN Document Server

    Lazio, T J W; Dietrick, J; Greenlees, E; Hogan, E; Jones, C; Hennig, L A

    2004-01-01

    We predict the radio flux densities of the extrasolar planets in the current census, making use of an empirical relation--the radiometric Bode's Law--determined from the five ``magnetic'' planets in the solar system (Earth and the four gas giants). Radio emission from these planets results from solar-wind powered electron currents depositing energy in the magnetic polar regions. We find that most of the known extrasolar planets should emit in the frequency range 10--1000 MHz and, under favorable circumstances, have typical flux densities as large as 1 mJy. We also describe an initial, systematic effort to search for radio emission in low radio frequency images acquired with the Very Large Array. The limits set by the VLA images (~ 300 mJy) are consistent with, but do not provide strong constraints on, the predictions of the model. Future radio telescopes, such as the Low Frequency Array (LOFAR) and the Square Kilometer Array (SKA), should be able to detect the known extrasolar planets or place austere limits ...

  16. Radiometric dating of the Siloam Tunnel, Jerusalem.

    Science.gov (United States)

    Frumkin, Amos; Shimron, Aryeh; Rosenbaum, Jeff

    2003-09-11

    The historical credibility of texts from the Bible is often debated when compared with Iron Age archaeological finds (refs. 1, 2 and references therein). Modern scientific methods may, in principle, be used to independently date structures that seem to be mentioned in the biblical text, to evaluate its historical authenticity. In reality, however, this approach is extremely difficult because of poor archaeological preservation, uncertainty in identification, scarcity of datable materials, and restricted scientific access into well-identified worship sites. Because of these problems, no well-identified Biblical structure has been radiometrically dated until now. Here we report radiocarbon and U-Th dating of the Siloam Tunnel, proving its Iron Age II date; we conclude that the Biblical text presents an accurate historic record of the Siloam Tunnel's construction. Being one of the longest ancient water tunnels lacking intermediate shafts, dating the Siloam Tunnel is a key to determining where and when this technological breakthrough took place. Siloam Tunnel dating also refutes a claim that the tunnel was constructed in the second century bc.

  17. Downstream processing and chromatography based analytical methods for production of vaccines, gene therapy vectors, and bacteriophages

    Science.gov (United States)

    Kramberger, Petra; Urbas, Lidija; Štrancar, Aleš

    2015-01-01

    Downstream processing of nanoplexes (viruses, virus-like particles, bacteriophages) is characterized by complexity of the starting material, number of purification methods to choose from, regulations that are setting the frame for the final product and analytical methods for upstream and downstream monitoring. This review gives an overview on the nanoplex downstream challenges and chromatography based analytical methods for efficient monitoring of the nanoplex production. PMID:25751122

  18. Downstream processing and chromatography based analytical methods for production of vaccines, gene therapy vectors, and bacteriophages.

    Science.gov (United States)

    Kramberger, Petra; Urbas, Lidija; Štrancar, Aleš

    2015-01-01

    Downstream processing of nanoplexes (viruses, virus-like particles, bacteriophages) is characterized by complexity of the starting material, number of purification methods to choose from, regulations that are setting the frame for the final product and analytical methods for upstream and downstream monitoring. This review gives an overview on the nanoplex downstream challenges and chromatography based analytical methods for efficient monitoring of the nanoplex production.

  19. RADIOMETRIC CALIBRATION OF MULTI-WAVELENGTH AIRBORNE LASER SCANNING DATA

    Directory of Open Access Journals (Sweden)

    C. Briese

    2012-07-01

    Full Text Available Airborne laser scanning (ALS is a widely used technique for the sampling of the earth's surface. Nowadays a wide range of ALS sensor systems with different technical specifications can be found. One parameter is the laser wavelength which leads to a sensitivity for the wavelength dependent backscatter characteristic of sensed surfaces. Current ALS sensors usually record next to the geometric information additional information on the recorded signal strength of each echo. In order to utilize this information for the study of the backscatter characteristic of the sensed surface, radiometric calibration is essential. This paper focuses on the radiometric calibration of multi-wavelength ALS data and is based on previous work on the topic of radiometric calibration of monochromatic (single-wavelength ALS data. After a short introduction the theory and whole workflow for calibrating ALS data radiometrically based on in-situ reference surfaces is presented. Furthermore, it is demonstrated that this approach for the monochromatic calibration can be used for each channel of multi-wavelength ALS data. The resulting active multi-channel radiometric image does not have any shadows and from a geometric viewpoint the position of the objects on top of the terrain surface is not altered (the result is a multi-channel true orthophoto. Within this paper the approach is demonstrated by three different single-wavelength ALS data acquisition campaigns (532nm, 1064nm and 1550nm covering the area of the city Horn (Austria. The results and practical issues are discussed.

  20. Outdoor relative radiometric calibration method using gray scale targets

    Institute of Scientific and Technical Information of China (English)

    DUAN; YiNi; YAN; Lei; YANG; Bin; JING; Xin; CHEN; Wei

    2013-01-01

    The radiometric calibration of remote sensors is a basis and prerequisite of information quantification in remote sensing. This paper proposes a method for outdoor relative radiometric calibration using gray scale targets. In this method, the idea of two substitutions is adopted. Sunlight is used to replace the integrating sphere light source, and gray scale targets are used to re-place the diffuser. In this way, images at different radiance levels obtained outdoors can calculate the relative radiometric cali-bration coefficients using the least square method. The characteristics of this method are as follows. Firstly, compared with la-boratory calibration, it greatly reduces the complexity of the calibration method and the test cost. Secondly, compared with the existing outdoor relative radiometric calibration of a single radiance level, it uses test images of different radiance levels to re-duce errors. Thirdly, it is easy to operate with fewer environmental requirements, has obvious advantages in the rapid calibra-tion of airborne remote sensors before or after flight and is practical in engineering. This paper theoretically and experimental-ly proves the feasibility of this method. Calibration experiments were conducted on the wide-view multispectral imager (WVMI) using this method, and the precision of this method was evaluated by analyzing the corrected images of large uniform targets on ground. The experiment results have demonstrated that the new method is effective and its precision meets the re-quirement of the absolute radiometric calibration.

  1. Radiometric Study of Soil Profiles in the Infrared Band

    Science.gov (United States)

    Ponomareva, T. V.; Ponomarev, E. I.

    2016-02-01

    The applicability of radiometric survey of soil profiles in the infrared range for the analysis of soil physical properties was studied. Radiometric data were obtained for different dates of the growing season for a number of soil profiles. The specificity of temperature profiles of texture-differentiated soils (Luvisols and Retisols) as related to weather conditions of the growing season was examined. The correlation analysis showed a close relationship between the air and surface soil temperatures and between the radiometric and thermodynamic soil temperatures in the upper 10 cm. In the studied profiles, the gradient of radiometric temperatures reached 0.5-0.8°C/cm in the humus horizons and sharply decreased at the depth of more than 15-20 cm. The gradient analysis of radiometric images made it possible to outline the boundaries of soil horizons. For the texture-differentiated soils, the most distinct boundaries were established between the gray-humus AY horizon and the underlying eluvial EL horizon in podzolic soils and between the AY horizon and the underlying humus-eluvial AEL horizon in gray soils.

  2. Radiometric rectification - Toward a common radiometric response among multidate, multisensor images

    Science.gov (United States)

    Hall, F. G.; Strebel, D. E.; Nickeson, J. E.; Goetz, S. J.

    1991-01-01

    A method is developed for relating scene digital counts among several images of the same scene by identifying radiometric control sets with mean reflectances that are basically constant. The average digital-count values of the control sets are utilized to compute linear transforms that relate digital count values between images. Two Landsat TM images are studied by means of the technique using simulations of a wide range of atmospheric conditions. In the visible and near-IR bands the algorithm effectively adjusts the surface reflectance for the effects of relative atmospheric differences to within 1 percent. The proposed method is found to be an effective relative correction procedure that can be used when atmospheric optical-depth data and calibration coefficients are not available.

  3. Radiometric Methods for Rapid Diagnosis of Viral Infection.

    Science.gov (United States)

    2014-09-26

    6/ NL IL 1-2 1-N6 U..V. -- V-- 1** ’~r I Ii’sW - -Kw RADIOMETRIC METHODS FOR RAPID DIAGNOSIS OF VIRAL INFECTION o Annual Report Min-Fu Tsan, M.D...REPORT DATE Command November 22, 1976 *U. S.. Army Medical Research and Development/ 13 NUMBER OF P!AGES Fort Detrick, Frederick, MD1 21701,5012 21...by black number) , Radiometric methods Virus r; fV 20. AISSY fRACT (Continue on, reverse sie it nwc. urr and ldvntity by block nuaibe,) -Vrtwo

  4. Microwave and Millimeter-Wave Radiometric Studies of Temperature, Water Vapor and Clouds

    Energy Technology Data Exchange (ETDEWEB)

    Westwater, Edgeworth

    2011-05-06

    The importance of accurate measurements of column amounts of water vapor and cloud liquid has been well documented by scientists within the Atmospheric Radiation Measurement (ARM) Program. At the North Slope of Alaska (NSA), both microwave radiometers (MWR) and the MWRProfiler (MWRP), been used operationally by ARM for passive retrievals of the quantities: Precipitable Water Vapor (PWV) and Liquid Water Path (LWP). However, it has been convincingly shown that these instruments are inadequate to measure low amounts of PWV and LWP. In the case of water vapor, this is especially important during the Arctic winter, when PWV is frequently less than 2 mm. For low amounts of LWP (< 50 g/m{sup 2}), the MWR and MWRP retrievals have an accuracy that is also not acceptable. To address some of these needs, in March-April 2004, NOAA and ARM conducted the NSA Arctic Winter Radiometric Experiment - Water Vapor Intensive Operational Period at the ARM NSA/Adjacent Arctic Ocean (NSA/AAO) site. After this experiment, the radiometer group at NOAA moved to the Center for Environmental Technology (CET) of the Department of Electrical and Computer Engineering of the University of Colorado at Boulder. During this 2004 experiment, a total of 220 radiosondes were launched, and radiometric data from 22.235 to 380 GHz were obtained. Primary instruments included the ARM MWR and MWRP, a Global Positioning System (GPS), as well as the CET Ground-based Scanning Radiometer (GSR). We have analyzed data from these instruments to answer several questions of importance to ARM, including: (a) techniques for improved water vapor measurements; (b) improved calibration techniques during cloudy conditions; (c) the spectral response of radiometers to a variety of conditions: clear, liquid, ice, and mixed phase clouds; and (d) forward modeling of microwave and millimeter wave brightness temperatures from 22 to 380 GHz. Many of these results have been published in the open literature. During the third year of

  5. Reintroducing radiometric surface temperature into the Penman-Monteith formulation

    DEFF Research Database (Denmark)

    Mallick, Kaniska; Bøgh, Eva; Trebs, Ivonne;

    2015-01-01

    Here we demonstrate a novel method to physically integrate radiometric surface temperature (TR) into the Penman-Monteith (PM) formulation for estimating the terrestrial sensible and latent heat fluxes (H and λE) in the framework of a modified Surface Temperature Initiated Closure (STIC). It combi...

  6. Radiometric dating by alpha spectrometry on uranium series nuclides

    NARCIS (Netherlands)

    Wijk, Albert van der

    1987-01-01

    De Engelse titel van dit proegschrift \\"Radiometric Dating by Alpha Spectometry on Uranium Series Nuclides\\" kan in het Nederlands wellicht het best worden weergegeven door \\"ouderdomsdbepalingen door stralingsmeting aan kernen uit de uraniumreeks met behulp van alfaspectometrie\\". In dit laatste ho

  7. Results of radiometric ash-content measurements at the Dudar coal mine, Hungary

    Energy Technology Data Exchange (ETDEWEB)

    Csoti, T. (Veszpremi Szenbanyak Dudari Banyauezeme, Dudar (Hungary))

    1983-12-01

    The regression analysis of the results of calorimetric and radiometric ash-content measurements of 1239 coal samples have shown that the calorific values which cannot be measured easily with traditional means can be approximated reasonably from the more easily measured radiometric data. The introduction of the radiometric measurements can be recommended for coal deposits. 6 refs.

  8. A Review of LIDAR Radiometric Processing: From Ad Hoc Intensity Correction to Rigorous Radiometric Calibration

    Directory of Open Access Journals (Sweden)

    Alireza G. Kashani

    2015-11-01

    Full Text Available In addition to precise 3D coordinates, most light detection and ranging (LIDAR systems also record “intensity”, loosely defined as the strength of the backscattered echo for each measured point. To date, LIDAR intensity data have proven beneficial in a wide range of applications because they are related to surface parameters, such as reflectance. While numerous procedures have been introduced in the scientific literature, and even commercial software, to enhance the utility of intensity data through a variety of “normalization”, “correction”, or “calibration” techniques, the current situation is complicated by a lack of standardization, as well as confusing, inconsistent use of terminology. In this paper, we first provide an overview of basic principles of LIDAR intensity measurements and applications utilizing intensity information from terrestrial, airborne topographic, and airborne bathymetric LIDAR. Next, we review effective parameters on intensity measurements, basic theory, and current intensity processing methods. We define terminology adopted from the most commonly-used conventions based on a review of current literature. Finally, we identify topics in need of further research. Ultimately, the presented information helps lay the foundation for future standards and specifications for LIDAR radiometric calibration.

  9. Application of a scattered-light radiometric power meter.

    Science.gov (United States)

    Caron, James N; DiComo, Gregory P; Ting, Antonio C; Fischer, Richard P

    2011-04-01

    The power measurement of high-power continuous-wave laser beams typically calls for the use of water-cooled thermopile power meters. Large thermopile meters have slow response times that can prove insufficient to conduct certain tests, such as determining the influence of atmospheric turbulence on transmitted beam power. To achieve faster response times, we calibrated a digital camera to measure the power level as the optical beam is projected onto a white surface. This scattered-light radiometric power meter saves the expense of purchasing a large area power meter and the required water cooling. In addition, the system can report the power distribution, changes in the position, and the spot size of the beam. This paper presents the theory of the scattered-light radiometric power meter and demonstrates its use during a field test at a 2.2 km optical range. © 2011 American Institute of Physics

  10. Radiometric microbiologic assay for the biologically active forms of niacin

    Energy Technology Data Exchange (ETDEWEB)

    Kertcher, J.A.; Guilarte, T.R.; Chen, M.F.; Rider, A.A.; McIntyre, P.A.

    1979-05-01

    A radiometric microbiologic assay has been developed for the determination of niacin in biologic fluids. Lactobacillus plantarum produced /sup 14/CO/sub 2/ from L-(U-/sup 14/C) malic acid in quantities proportional to the amount of niacin present. The assay is specific for the biologically active forms of niacin in humans. Thirty normal hemolysates were analyzed and the values ranged from 13.0 to 17.8 ..mu..g niacin/ml RBC (mean = 15.27 +- 1.33 s.d.). Good recovery and reproducibility studies were obtained with this assay. On thirty blood samples, correlation was excellent between the radiometric and the conventional turbidimetric assays.

  11. SLC-off Landsat-7 ETM+ reflective band radiometric calibration

    Science.gov (United States)

    Markham, B.L.; Barsi, J.A.; Thome, K.J.; Barker, J.L.; Scaramuzza, P.L.; Helder, D.L.; ,

    2005-01-01

    Since May 31, 2003, when the scan line corrector (SLC) on the Landsat-7 ETM+ failed, the primary foci of Landsat-7 ETM+ analyses have been on understanding and attempting to fix the problem and later on developing composited products to mitigate the problem. In the meantime, the Image Assessment System personnel and vicarious calibration teams have continued to monitor the radiometric performance of the ETM+ reflective bands. The SLC failure produced no measurable change in the radiometric calibration of the ETM+ bands. No trends in the calibration are definitively present over the mission lifetime, and, if present, are less than 0.5% per year. Detector 12 in Band 7 dropped about 0.5% in response relative to the rest of the detectors in the band in May 2004 and recovered back to within 0.1% of its initial relative gain in October 2004.

  12. The OLI Radiometric Scale Realization Round Robin Measurement Campaign

    Science.gov (United States)

    Cutlip, Hansford; Cole,Jerold; Johnson, B. Carol; Maxwell, Stephen; Markham, Brian; Ong, Lawrence; Hom, Milton; Biggar, Stuart

    2011-01-01

    A round robin radiometric scale realization was performed at the Ball Aerospace Radiometric Calibration Laboratory in January/February 2011 in support of the Operational Land Imager (OLI) Program. Participants included Ball Aerospace, NIST, NASA Goddard Space Flight Center, and the University of Arizona. The eight day campaign included multiple observations of three integrating sphere sources by nine radiometers. The objective of the campaign was to validate the radiance calibration uncertainty ascribed to the integrating sphere used to calibrate the OLI instrument. The instrument level calibration source uncertainty was validated by quatnifying: (1) the long term stability of the NIST calibrated radiance artifact, (2) the responsivity scale of the Ball Aerospace transfer radiometer and (3) the operational characteristics of the large integrating sphere.

  13. Development and calibration of UV/VUV radiometric sources

    Science.gov (United States)

    Bridges, J. M.

    1993-01-01

    A program exists at NIST to calibrate radiometric sources for the spectral range from 118-350 nm. These include deuterium lamps, hollow-cathode lamps, RF-excited dimer lamps, and wall-stabilized argon arcs. Sources have been calibrated for and used by researchers in solar physics, astrophysics, atmospheric physics (ozone measurements), magnetically controlled fusion, and photobiology. The argon arcs were developed in our laboratory, and provide intense sources of both radiance and irradiance. Calibrations are performed relative to two primary sources, a wall-stabilized hydrogen arc and a 12,000 K black-body line arc, both developed in our laboratory. Also we recently have begun periodic calibrations on the NIST storage ring, SURF II, to insure consistency between our respective radiometric bases. Various sources have been calibrated for space' applications, including several which are flyable. Also, some development and testing of radiometers for semiconductor lithography were recently carried out with an intense argon arc source.

  14. Determination of plutonium isotopes (238Pu, 239Pu, 240Pu, 241Pu) in environmental samples using radiochemical separation combined with radiometric and mass spectrometric measurements

    DEFF Research Database (Denmark)

    Xu, Yihong; Qiao, Jixin; Hou, Xiaolin

    2014-01-01

    This paper reports an analytical method for the determination of plutonium isotopes (238Pu, 239Pu, 240Pu, 241Pu) in environmental samples using anion exchange chromatography in combination with extraction chromatography for chemical separation of Pu. Both radiometric methods (liquid scintillation...

  15. Radiometric Methods for Rapid Diagnosis of Viral Infection.

    Science.gov (United States)

    1975-11-01

    4, 6, 24, 48, and 72 hours postinfection, infection time beginning when the 14C-labeled medium was added. Nucleic acid sT, thesis system. Stationary...coccus epidermidis, Pseudomonas aeruginosa, and Acinetobacter caloaceticus var. anitratus) had no effect on the DNA synthesis of HSV-1 infected or...7 UNCLASS 41 RADIOMETRIC METHODS FOR RAPID DIAGNIS F VIRA ~ /fl INFECTION (U) JOHNS HOPKINS UNIV BALTIMORE MDUNC . IFEDH N WAG ER FT AL. NOV 75

  16. Quantifying the Dynamic Ocean Surface Using Underwater Radiometric Measurements

    Science.gov (United States)

    2015-03-31

    2. REPORT DATE 3. DATES COVERED (From - To) 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER 6. AUTHOR(S) 7. PERFORMING ORGANIZATION NAME(S) AND...WORK UNIT NUMBER 1. REPORT DATE (DD-MM-YYYY) 16. SECURITY CLASSIFICATION OF: PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. 31-03-2015...Final March 2013 -- February 2015 Quantifying the Dynamic Ocean Surface Using Underwater Radiometric Measurements N00014-13-1-0352 Yue, Dick K.P

  17. Radiometric dating by alpha spectrometry on uranium series nuclides

    OpenAIRE

    Wijk, Albert van der

    1987-01-01

    De Engelse titel van dit proegschrift \\"Radiometric Dating by Alpha Spectometry on Uranium Series Nuclides\\" kan in het Nederlands wellicht het best worden weergegeven door \\"ouderdomsdbepalingen door stralingsmeting aan kernen uit de uraniumreeks met behulp van alfaspectometrie\\". In dit laatste hoofdstuk wil ik proberen om op beknopte, ook voor de niet gespecialiseerde lezer, de inhoud en achtergrond van het onderzoek samen te vatten. Aan het eind van de vorige eeuw werd het verschijnsel ra...

  18. The Radiometric Bode’s law and Extrasolar Planets

    Science.gov (United States)

    2004-09-01

    THE RADIOMETRIC BODE’S LAW AND EXTRASOLAR PLANETS T. Joseph, W. Lazio Naval Research Laboratory, Code 7213, Washington, DC 20375-5351; joseph.lazio...the magnetic polar regions. We find that most of the known extrasolar planets should emit in the frequency range 10–1000 MHz and, under favorable...detect the known extrasolar planets or place austere limits on their radio emission. Planets with masses much lower than those in the current census

  19. Novel techniques for the analysis of the TOA radiometric uncertainty

    Science.gov (United States)

    Gorroño, Javier; Banks, Andrew; Gascon, Ferran; Fox, Nigel P.; Underwood, Craig I.

    2016-10-01

    In the framework of the European Copernicus programme, the European Space Agency (ESA) has launched the Sentinel-2 (S2) Earth Observation (EO) mission which provides optical high spatial -resolution imagery over land and coastal areas. As part of this mission, a tool (named S2-RUT, from Sentinel-2 Radiometric Uncertainty Tool) estimates the radiometric uncertainties associated to each pixel using as input the top-of-atmosphere (TOA) reflectance factor images provided by ESA. The initial version of the tool has been implemented — code and user guide available1 — and integrated as part of the Sentinel Toolbox. The tool required the study of several radiometric uncertainty sources as well as the calculation and validation of the combined standard uncertainty in order to estimate the TOA reflectance factor uncertainty per pixel. Here we describe the recent research in order to accommodate novel uncertainty contributions to the TOA reflectance uncertainty estimates in future versions of the tool. The two contributions that we explore are the radiometric impact of the spectral knowledge and the uncertainty propagation of the resampling associated to the orthorectification process. The former is produced by the uncertainty associated to the spectral calibration as well as the spectral variations across the instrument focal plane and the instrument degradation. The latter results of the focal plane image propagation into the provided orthoimage. The uncertainty propagation depends on the radiance levels on the pixel neighbourhood and the pixel correlation in the temporal and spatial dimensions. Special effort has been made studying non-stable scenarios and the comparison with different interpolation methods.

  20. A Radiometric Uncertainty Tool for the Sentinel 2 Mission

    Directory of Open Access Journals (Sweden)

    Javier Gorroño

    2017-02-01

    Full Text Available In the framework of the European Copernicus programme, the European Space Agency (ESA has launched the Sentinel-2 (S2 Earth Observation (EO mission which provides optical high spatial resolution imagery over land and coastal areas. As part of this mission, a tool (named S2-RUT, from Sentinel-2 Radiometric Uncertainty Tool has been developed. The tool estimates the radiometric uncertainty associated with each pixel in the top-of-atmosphere (TOA reflectance factor images provided by ESA. This paper describes the design and development process of the initial version of the S2-RUT tool. The initial design step describes the S2 radiometric model where a set of uncertainty contributors are identified. Each of the uncertainty contributors is specified by reviewing the pre- and post-launch characterisation. The identified uncertainty contributors are combined following the guidelines in the ‘Guide to Expression of Uncertainty in Measurement’ (GUM model and this combination model is further validated by comparing the results to a multivariate Monte Carlo Method (MCM. In addition, the correlation between the different uncertainty contributions and the impact of simplifications in the combination model have been studied. The software design of the tool prioritises an efficient strategy to read the TOA reflectance factor images, extract the auxiliary information from the metadata in the satellite products and the codification of the resulting uncertainty image. This initial version of the tool has been implemented and integrated as part of the Sentinels Application Platform (SNAP.

  1. Size-exclusion chromatography based on silica-diol for the analysis of the proinsulin fusion protein.

    Science.gov (United States)

    Gusarova, V; Vorobjeva, T; Gusarov, D; Lasman, V; Bayramashvili, D

    2007-12-28

    Size-exclusion chromatography based on silica-diol sorbent was employed to analyze the recombinant proinsulin fusion protein obtained during the process of refolding and the following ion-exchange purification. The assay was qualified as a control method estimating its accuracy, precision, linearity, limit of detection, limits of quantitation, specificity, and robustness. The results show the reliability for the intended use.

  2. Site characterization for calibration of radiometric sensors using vicarious method

    Science.gov (United States)

    Parihar, Shailesh; Rathore, L. S.; Mohapatra, M.; Sharma, A. K.; Mitra, A. K.; Bhatla, R.; Singh, R. S.; Desai, Yogdeep; Srivastava, Shailendra S.

    2016-05-01

    Radiometric performances of earth observation satellite/sensors vary from ground pre-launch calibration campaign to post launch period extended to lifetime of the satellite due to launching vibrations. Therefore calibration is carried out worldwide through various methods throughout satellite lifetime. In India Indian Space Research Organization (ISRO) calibrates the sensor of Resourcesat-2 satellite by vicarious method. One of these vicarious calibration methods is the reflectance-based approach that is applied in this study for radiometric calibration of sensors on-board Resouresat-2 satellite. The results of ground-based measurement of atmospheric conditions and surface reflectance are made at Bap, Rajasthan Calibration/Validation (Cal/Val) site. Cal/Val observations at site were carried out with hyper-spectral Spectroradiometer covering spectral range of 350nm- 2500nm for radiometric characterization of the site. The Sunphotometer/Ozonometer for measuring the atmospheric parameters has also been used. The calibrated radiance is converted to absolute at-sensor spectral reflectance and Top-Of-Atmosphere (TOA) radiance. TOA radiance was computed using radiative transfer model `Second simulation of the satellite signal in the solar spectrum' (6S), which can accurately simulate the problems introduced by the presence of the atmosphere along the path from Sun to target (surface) to Sensor. The methodology for band averaged reflectance retrieval and spectral reflectance fitting process are described. Then the spectral reflectance and atmospheric parameters are put into 6S code to predict TOA radiance which compare with Resourcesat-2 radiance. Spectral signature and its reflectance ratio indicate the uniformity of the site. Thus the study proves that the selected site is suitable for vicarious calibration of sensor of Resourcesat-2. Further the study demonstrates the procedure for similar exercise for site selection for Cal/Val analysis of other satellite over India

  3. Spectrally and Radiometrically Stable, Wideband, Onboard Calibration Source

    Science.gov (United States)

    Coles, James B.; Richardson, Brandon S.; Eastwood, Michael L.; Sarture, Charles M.; Quetin, Gregory R.; Porter, Michael D.; Green, Robert O.; Nolte, Scott H.; Hernandez, Marco A.; Knoll, Linley A.

    2013-01-01

    The Onboard Calibration (OBC) source incorporates a medical/scientific-grade halogen source with a precisely designed fiber coupling system, and a fiber-based intensity-monitoring feedback loop that results in radiometric and spectral stabilities to within less than 0.3 percent over a 15-hour period. The airborne imaging spectrometer systems developed at the Jet Propulsion Laboratory incorporate OBC sources to provide auxiliary in-use system calibration data. The use of the OBC source will provide a significant increase in the quantitative accuracy, reliability, and resulting utility of the spectral data collected from current and future imaging spectrometer instruments.

  4. Virtual and remote experiments for radiometric and photometric measurements

    Science.gov (United States)

    Thoms, L.-J.; Girwidz, R.

    2017-09-01

    The analysis of spectra is fundamental to our modern understanding of wave optics and colour perception. Since spectrometers are expensive, and accurate calibration is necessary to achieve high quality spectra, we developed a remote lab on optical spectrometry. With this tool, students can carry out real experiments over the Internet. In this article the pros and cons of remote labs, the physical background of optical spectrometry, and the development and use of a radiometric remote lab for higher education are discussed. The remote lab is freely accessible to everyone at http://virtualremotelab.net.

  5. Peat Mapping Associations of Airborne Radiometric Survey Data

    Directory of Open Access Journals (Sweden)

    David Beamish

    2014-01-01

    Full Text Available This study considers recent airborne radiometric (gamma ray survey data, obtained at high-resolution, across various regions of the UK. The datasets all display a very evident attenuation of signal in association with peat, and intra-peat variations are observed. The geophysical response variations are examined in detail using example data sets across lowland areas (raised bogs, meres, fens and afforested peat and upland areas of blanket bog, together with associated wetland zones. The radiometric data do not map soils per se. The bedrock (the radiogenic parent provides a specific amplitude level. Attenuation of this signal level is then controlled by moisture content in conjunction with the density and porosity of the soil cover. Both soil and bedrock variations need to be jointly assessed. The attenuation theory, reviewed here, predicts that the behaviour of wet peat is distinct from most other soil types. Theory also predicts that the attenuation levels observed across wet peatlands cannot be generally used to map variations in peat thickness. Four survey areas at various scales, across England, Scotland, Wales and Ireland are used to demonstrate the ability of the airborne data to map peat zones. A 1:50 k national mapping of deep peat is used to provide control although variability in the definition of peat zones across existing databases is also demonstrated.

  6. Off-line radiometric analysis of Planck-LFI data

    Energy Technology Data Exchange (ETDEWEB)

    Tomasi, M; Mennella, A; Bersanelli, M [Dipartimento di Fisica, Universita degli Studi di Milano, Via Celoria 16, 20133 Milano (Italy); Galeotta, S; Maris, M [LFI-DPC INAF-OATs, Via Tiepolo 11, 34131 Trieste (Italy); Lowe, S R [Jodrell Bank Centre for Astrophysics, The University of Manchester, Manchester, M13 9PL (United Kingdom); Mendes, L [Planck Science Office, European Space Agency, ESAC, P.O. box 78, 28691 Villanueva de la Canada, Madrid (Spain); Leonardi, R; Meinhold, P [Department of Physics, University of California, Santa Barbara, CA 93106-9530 (United States); Villa, F; Sandri, M; Cuttaia, F; Terenzi, L; Valenziano, L; Butler, R C [INAF-IASF Bologna, Via Gobetti, 101, 40129, Bologna (Italy); Cappellini, B [INAF-IASF Milano, Via E. Bassini 15, 20133 Milano (Italy); Gregorio, A [Department of Physics, University of Trieste, Via Valerio, 2 Trieste I-34127 (Italy); Salmon, M J [Departamento de IngenierIa de Comunicaciones, Universidad de Cantabria, Avenida de los Castros s/n. 39005 Santander (Spain); Binko, P [ISDC Data Centre for Astrophysics, University of Geneva, ch. d' Ecogia 16, 1290 Versoix (Switzerland); D' Arcangelo, O, E-mail: tomasi@lambrate.inaf.i [IFP-CNR, Via Cozzi 53, Milano (Italy)

    2009-12-15

    The Planck Low Frequency Instrument (LFI) is an array of 22 pseudo-correlation radiometers on-board the Planck satellite to measure temperature and polarization anisotropies in the Cosmic Microwave Background (CMB) in three frequency bands (30, 44 and 70 GHz). To calibrate and verify the performances of the LFI, a software suite named LIFE has been developed. Its aims are to provide a common platform to use for analyzing the results of the tests performed on the single components of the instrument (RCAs, Radiometric Chain Assemblies) and on the integrated Radiometric Array Assembly (RAA). Moreover, its analysis tools are designed to be used during the flight as well to produce periodic reports on the status of the instrument. The LIFE suite has been developed using a multi-layered, cross-platform approach. It implements a number of analysis modules written in RSI IDL, each accessing the data through a portable and heavily optimized library of functions written in C and C++. One of the most important features of LIFE is its ability to run the same data analysis codes both using ground test data and real flight data as input. The LIFE software suite has been successfully used during the RCA/RAA tests and the Planck Integrated System Tests. Moreover, the software has also passed the verification for its in-flight use during the System Operations Verification Tests, held in October 2008.

  7. a Comparison of LIDAR Reflectance and Radiometrically Calibrated Hyperspectral Imagery

    Science.gov (United States)

    Roncat, A.; Briese, C.; Pfeifer, N.

    2016-06-01

    In order to retrieve results comparable under different flight parameters and among different flight campaigns, passive remote sensing data such as hyperspectral imagery need to undergo a radiometric calibration. While this calibration, aiming at the derivation of physically meaningful surface attributes such as a reflectance value, is quite cumbersome for passively sensed data and relies on a number of external parameters, the situation is by far less complicated for active remote sensing techniques such as lidar. This fact motivates the investigation of the suitability of full-waveform lidar as a "single-wavelength reflectometer" to support radiometric calibration of hyperspectral imagery. In this paper, this suitability was investigated by means of an airborne hyperspectral imagery campaign and an airborne lidar campaign recorded over the same area. Criteria are given to assess diffuse reflectance behaviour; the distribution of reflectance derived by the two techniques were found comparable in four test areas where these criteria were met. This is a promising result especially in the context of current developments of multi-spectral lidar systems.

  8. Off-line radiometric analysis of Planck/LFI data

    CERN Document Server

    Tomasi, M; Galeotta, S; Lowe, S R; Mendes, L; Leonardi, R; Villa, F; Cappellini, B; Gregorio, A; Meinhold, P; Sandri, M; Cuttaia, F; Terenzi, L; Maris, M; Valenziano, L; Salmon, M J; Bersanelli, M; Binko, P; Butler, R C; D'Arcangelo, O; Fogliani, S; Frailis, M; Franceschi, E; Gasparo, F; Maggio, G; Maino, D; Malaspina, M; Mandolesi, N; Manzato, P; Meharga, M; Morgante, G; Morisset, N; Pasian, F; Perrotta, F; Rohlfs, R; Turler, M; Zacchei, A; Zonca, A; 10.1088/1748-0221/4/12/T12020

    2009-01-01

    The Planck Low Frequency Instrument (LFI) is an array of 22 pseudo-correlation radiometers on-board the Planck satellite to measure temperature and polarization anisotropies in the Cosmic Microwave Background (CMB) in three frequency bands (30, 44 and 70 GHz). To calibrate and verify the performances of the LFI, a software suite named LIFE has been developed. Its aims are to provide a common platform to use for analyzing the results of the tests performed on the single components of the instrument (RCAs, Radiometric Chain Assemblies) and on the integrated Radiometric Array Assembly (RAA). Moreover, its analysis tools are designed to be used during the flight as well to produce periodic reports on the status of the instrument. The LIFE suite has been developed using a multi-layered, cross-platform approach. It implements a number of analysis modules written in RSI IDL, each accessing the data through a portable and heavily optimized library of functions written in C and C++. One of the most important features ...

  9. Microwave radiometric signatures of temperature anomalies in tissue

    Science.gov (United States)

    Kelly, Patrick; Sobers, Tamara; St. Peter, Benjamin; Siqueira, Paul; Capraro, Geoffrey

    2012-03-01

    Because of its ability to measure the temperature-dependent power of electromagnetic radiation emitted from tissue down to several centimeters beneath the skin, microwave radiometry has long been of interest as a means for identifying the internal tissue temperature anomalies that arise from abnormalities in physiological parameters such as metabolic and blood perfusion rates. However, the inherent lack of specificity and resolution in microwave radiometer measurements has limited the clinical usefulness of the technique. The idea underlying this work is to make use of information (assumed to be available from some other modality) about the tissue configuration in the volume of interest to study and improve the accuracy of anomaly detection and estimation from radiometric data. In particular, knowledge of the specific anatomy and the properties of the overall measurement system enable determination of the signatures of localized physiological abnormalities in the radiometry data. These signatures are used to investigate the accuracy with which the location of an anomaly can be determined from radiometric measurements. Algorithms based on matches to entries in a signature dictionary are developed for anomaly detection and estimation. The accuracy of anomaly identification is improved when the coupling of power from the body to the sensor is optimized. We describe the design of a radiometer waveguide having dielectric properties appropriate for biomedical applications.

  10. Reduction of Radiometric Miscalibration—Applications to Pushbroom Sensors

    Directory of Open Access Journals (Sweden)

    Sigrid Roessner

    2011-06-01

    Full Text Available The analysis of hyperspectral images is an important task in Remote Sensing. Foregoing radiometric calibration results in the assignment of incident electromagnetic radiation to digital numbers and reduces the striping caused by slightly different responses of the pixel detectors. However, due to uncertainties in the calibration some striping remains. This publication presents a new reduction framework that efficiently reduces linear and nonlinear miscalibrations by an image-driven, radiometric recalibration and rescaling. The proposed framework—Reduction Of Miscalibration Effects (ROME—considering spectral and spatial probability distributions, is constrained by specific minimisation and maximisation principles and incorporates image processing techniques such as Minkowski metrics and convolution. To objectively evaluate the performance of the new approach, the technique was applied to a variety of commonly used image examples and to one simulated and miscalibrated EnMAP (Environmental Mapping and Analysis Program scene. Other examples consist of miscalibrated AISA/Eagle VNIR (Visible and Near Infrared and Hawk SWIR (Short Wave Infrared scenes of rural areas of the region Fichtwald in Germany and Hyperion scenes of the Jalal-Abad district in Southern Kyrgyzstan. Recovery rates of approximately 97% for linear and approximately 94% for nonlinear miscalibrated data were achieved, clearly demonstrating the benefits of the new approach and its potential for broad applicability to miscalibrated pushbroom sensor data.

  11. RADIOMETRIC AND GEOMETRIC ACCURACY ANALYSIS OF RASAT PAN IMAGERY

    Directory of Open Access Journals (Sweden)

    S. Kocaman

    2016-06-01

    Full Text Available RASAT is the second Turkish Earth Observation satellite which was launched in 2011. It operates with pushbroom principle and acquires panchromatic and MS images with 7.5 m and 15 m resolutions, respectively. The swath width of the sensor is 30 km. The main aim of this study is to analyse the radiometric and geometric quality of RASAT images. A systematic validation approach for the RASAT imagery and its products is being applied. RASAT image pair acquired over Kesan city in Edirne province of Turkey are used for the investigations. The raw RASAT data (L0 are processed by Turkish Space Agency (TUBITAK-UZAY to produce higher level image products. The image products include radiometrically processed (L1, georeferenced (L2 and orthorectified (L3 data, as well as pansharpened images. The image quality assessments include visual inspections, noise, MTF and histogram analyses. The geometric accuracy assessment results are only preliminary and the assessment is performed using the raw images. The geometric accuracy potential is investigated using 3D ground control points extracted from road intersections, which were measured manually in stereo from aerial images with 20 cm resolution and accuracy. The initial results of the study, which were performed using one RASAT panchromatic image pair, are presented in this paper.

  12. Absorbance detector for high performance liquid chromatography based on a deep-UV light-emitting diode at 235nm.

    Science.gov (United States)

    da Silveira Petruci, João Flavio; Liebetanz, Michael G; Cardoso, Arnaldo Alves; Hauser, Peter C

    2017-08-25

    In this communication, we describe a flow-through optical absorption detector for HPLC using for the first time a deep-UV light-emitting diode with an emission band at 235nm as light source. The detector is also comprised of a UV-sensitive photodiode positioned to enable measurement of radiation through a flow-through cuvette with round aperture of 1mm diameter and optical path length of 10mm, and a second one positioned as reference photodiode; a beam splitter and a power supply. The absorbance was measured and related to the analyte concentration by emulating the Lambert-Beer law with a log-ratio amplifier circuitry. This detector showed noise levels of 0.30mAU, which is comparable with our previous LED-based detectors employing LEDs at 280 and 255nm. The detector was coupled to a HPLC system and successfully evaluated for the determination of the anti-diabetic drugs pioglitazone and glimepiride in an isocratic separation and the benzodiazepines flurazepam, oxazepam and clobazam in a gradient elution. Good linearities (r>0.99), a precision better than 0.85% and limits of detection at sub-ppm levels were achieved. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Evaluating Radiometric Measurements Using a Fixed 45 Degrees Responsivity and Zenith Angle Dependent Responsivities (Poster)

    Energy Technology Data Exchange (ETDEWEB)

    Dooraghi, M.; Habte, A.; Reda, I.; Sengupta, M.; Gotseff, P.; Andreas, A.; Anderberg, M.

    2014-03-01

    This poster seeks to demonstrate the importance and application of an existing but unused approach that ultimately reduces the uncertainty of radiometric measurements. Current radiometric data is based on a single responsivity value that introduces significant uncertainty to the data, however, through using responsivity as a function of solar zenith angle, the uncertainty could be decreased by 50%.

  14. Evaluating Radiometric Measurements Using a Fixed 45 Degrees Responsivity and Zenith Angle Dependent Responsivities (Poster)

    Energy Technology Data Exchange (ETDEWEB)

    Dooraghi, M.; Habte, A.; Reda, I.; Sengupta, M.; Gotseff, P.; Andreas, A.; Anderberg, M.

    2014-03-01

    This poster seeks to demonstrate the importance and application of an existing but unused approach that ultimately reduces the uncertainty of radiometric measurements. Current radiometric data is based on a single responsivity value that introduces significant uncertainty to the data, however, through using responsivity as a function of solar zenith angle, the uncertainty could be decreased by 50%.

  15. The Landsat Data Continuity Mission Operational Land Imager (OLI) Radiometric Calibration

    Science.gov (United States)

    Markham, Brian L.; Dabney, Philip W.; Murphy-Morris, Jeanine E.; Knight, Edward J.; Kvaran, Geir; Barsi, Julia A.

    2010-01-01

    The Operational Land Imager (OLI) on the Landsat Data Continuity Mission (LDCM) has a comprehensive radiometric characterization and calibration program beginning with the instrument design, and extending through integration and test, on-orbit operations and science data processing. Key instrument design features for radiometric calibration include dual solar diffusers and multi-lamped on-board calibrators. The radiometric calibration transfer procedure from NIST standards has multiple checks on the radiometric scale throughout the process and uses a heliostat as part of the transfer to orbit of the radiometric calibration. On-orbit lunar imaging will be used to track the instruments stability and side slither maneuvers will be used in addition to the solar diffuser to flat field across the thousands of detectors per band. A Calibration Validation Team is continuously involved in the process from design to operations. This team uses an Image Assessment System (IAS), part of the ground system to characterize and calibrate the on-orbit data.

  16. ROSCAM: a 95-GHz radiometric one-second camera

    Science.gov (United States)

    Smith, Roger M.; Sundstrom, Bryce M.; Belcher, Byron W.; Ewen, Doc

    1998-08-01

    The ability to obtain millimeter wave images under a variety of environmental conditions, such as rain, snow, fog, smoke, dust, etc., has numerous DoD as well as commercial applications. The demonstrated ability to look through doors, walls and clothing has recently extended potential millimeter wave applications to contraband detection and surveillance within buildings. Though the phenomenology supports the generation of high quality millimeter wave images, present-day frame time capabilities limit the use of millimeter wave cameras. Several solutions to frame time reduction are currently being investigated within government and industry. Two popular approaches include: (1) Electronic scanning focal plane arrays (FPA); (2) Mechanical raster scanning of a single antenna beam. One significant difference between the two approaches noted above is the number of receiving channels required. This is important because camera cost is driven by the number of receiver channels used in a camera, as well as the added complexities associated with inter-channel gain stability. There are a number of applications that do not require a motion picture capability. Images obtained sequentially at a nominal rate of one per second would satisfy the needs of a wide range of applications. It is evident, however, that the motion picture quality of a starring FPA may ultimately reduce the market for one-second cameras. In the interim, the one-second camera fills an important need. The goal of the Radiometric One Second Camera (ROSCAM) investigation is to demonstrate a practical millimeter-wave imaging (MMWI) camera, with a frame time of approximately one second. The approach combines a high-speed mechanical raster scanning antenna system with a single-channel radiometric receiving system. For baseline comparison, it is assumed that the scene is comprised of 1,000 pixels, each sampled for one millisecond, to generate a single frame in one second. The ROSCAM is based on combining a state

  17. [In-flight absolute radiometric calibration of UAV multispectral sensor].

    Science.gov (United States)

    Chen, Wei; Yan, Lei; Gou, Zhi-Yang; Zhao, Hong-Ying; Liu, Da-Ping; Duan, Yi-Ni

    2012-12-01

    Based on the data of the scientific experiment in Urad Front Banner for UAV Remote Sensing Load Calibration Field project, with the help of 6 hyperspectral radiometric targets with good Lambertian property, the wide-view multispectral camera in UAV was calibrated adopting reflectance-based method. The result reveals that for green, red and infrared channel, whose images were successfully captured, the linear correlation coefficients between the DN and radiance are all larger than 99%. In final analysis, the comprehensive error is no more than 6%. The calibration results demonstrate that the hyperspectral targets equipped by the calibration field are well suitable for air-borne multispectral load in-flight calibration. The calibration result is reliable and could be used in the retrieval of geophysical parameters.

  18. Radiometric Calibrations, Measurements, and Standards Development at NREL: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Myers, D. R.; Andreas, A.; Stoffel, T.; Reda, I.; Wilcox, S.; Gotseff, P.; Kay, B.

    2001-10-01

    Presented at the 2001 NCPV Program Review Meeting: Radiometric calibrations, measurements, and standards development at NREL. We describe proposed revisions to current reference standard spectral distributions used to evaluate photovoltaic device performance and durability of materials. Improvements in broadband outdoor radiometer calibrations reduce uncertainties in broadband radiometer calibrations. We report a method to quantify the rate of change of broadband radiometer responsivities as a function of integrated exposure to irradiance and thermal energy. The results of applying a vector of calibration factors or responsivities to field data to remove zenith-angle dependent errors in global solar radiation measurements are shown. We report on the relative sensitivity of radiometers to daily versus biweekly cleaning.

  19. Simulation study of element plastic migration from radiometric measurements

    Energy Technology Data Exchange (ETDEWEB)

    Rosa, Faena M.L.; Manzoli, Jose Eduardo; Saiki, Mitiko [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Soares, Eufemia Paez [Escola SENAI Fundacao Zerrenner, Sao Paulo, SP (Brazil)], E-mail: eufemia@sp.senai.br

    2007-07-01

    Element migration from plastic packaging to either foodstuffs or medicine is a serious public health. Many conventional experimental techniques such as chromatography-mass spectrometry, atomic absorption spectroscopy, inductively coupled plasma spectroscopy or calorimetric methods are used to measure total and specific migration of components from plastic packaging. The radiometric method is also used to measure the element migration. In this study a numerical technique was employed to simulate the experimental migration results obtained from measurements of elements from dairy product polymeric packages into 3% acetic acid solution which is a normative food simulant. This numerical technique can be used as complementary tool for the experimental measurements, allowing for a better understanding of the diffusion process and to estimate element migration situations not experimentally measured. (author)

  20. LFI Radiometric Chain Assembly (RCA) data handling "Rachel"

    CERN Document Server

    Malaspina, M; Battaglia, P; Binko, P; Butler, R C; D'Arcangelo, O; Fogliani, S; Frailis, M; Franceschet, C; Galeotta, S; Gasparo, F; Gregorio, A; Lapolla, M; Leonardi, R; Maggio, G; Mandolesi, N; Manzato, P; Maris, M; Meharga, M; Meinhold, P; Morisset, N; Pasian, F; Perrotta, F; Rohlfs, R; Sandri, M; Tomasi, M; Turler, M; Zacchei, A; Zonca, A; 10.1088/1748-0221/4/12/T12017

    2009-01-01

    This paper is part of the Prelaunch status LFI papers published on JINST (http://www.iop.org/EJ/journal/-page=extra.proc5/1748-0221). Planck's Low Frequency Instrument is an array of 22 pseudo-correlation radiometers at 30, 44, and 70 GHz. Before integrating the overall array assembly, a first set of tests has been performed for each radiometer chain assembly (RCA), consisting of two radiometers. In this paper, we describe Rachel, a software application which has been purposely developed and used during the RCA test campaign to carry out both near-realtime on-line data analysis and data storage (in FITS format) of the raw output from the radiometric chains.

  1. Development of a portable ambient temperature radiometric assaying instrument

    Energy Technology Data Exchange (ETDEWEB)

    Lavietes, A.D.; McQuaid, J.H.; Ruhter, W.D.

    1994-10-01

    There is a strong need for portable radiometric instrumentation that can accurately confirm the presence of nuclear materials and allow isotopic analysis of radionuclides in the field. To fulfill this need we are developing a hand-held, non-cryogenic, low-power gamma- and x-ray measurement and analysis instrument that can both search and then accurately verify the presence of nuclear materials. We report on the use of cadmium zinc telluride detectors, signal processing electronics, and the new field-portable instrument based on the MicroNOMAD Multichannel Analyzer from EG&G ORTBC. We also describe the isotopic analysis that allows uranium enrichment measurements to be made accurately in the field.

  2. New Sentinel-2 radiometric validation approaches (SEOM program)

    Science.gov (United States)

    Bruniquel, Véronique; Lamquin, Nicolas; Ferron, Stéphane; Govaerts, Yves; Woolliams, Emma; Dilo, Arta; Gascon, Ferran

    2016-04-01

    SEOM is an ESA program element whose one of the objectives aims at launching state-of-the-art studies for the scientific exploitation of operational missions. In the frame of this program, ESA awarded ACRI-ST and its partners Rayference and National Physical Laboratory (NPL) early 2016 for a R&D study on the development and intercomparison of algorithms for validating the Sentinel-2 radiometric L1 data products beyond the baseline algorithms used operationally in the frame of the S2 Mission Performance Centre. In this context, several algorithms have been proposed and are currently in development: The first one is based on the exploitation of Deep Convective Cloud (DCC) observations over ocean. This method allows an inter-band radiometry validation from the blue to the NIR (typically from B1 to B8a) from a reference band already validated for example with the well-known Rayleigh method. Due to their physical properties, DCCs appear from the remote sensing point of view to have bright and cold tops and they can be used as invariant targets to monitor the radiometric response degradation of reflective solar bands. The DCC approach is statistical i.e. the method shall be applied on a large number of measurements to derive reliable statistics and decrease the impact of the perturbing contributors. The second radiometric validation method is based on the exploitation of matchups combining both concomitant in-situ measurements and Sentinel-2 observations. The in-situ measurements which are used here correspond to measurements acquired in the frame of the RadCalNet networks. The validation is performed for the Sentinel-2 bands similar to the bands of the instruments equipping the validation site. The measurements from the Cimel CE 318 12-filters BRDF Sun Photometer installed recently in the Gobabeb site near the Namib desert are used for this method. A comprehensive verification of the calibration requires an analysis of MSI radiances over the full dynamic range

  3. JPSS-1 VIIRS pre-launch radiometric performance

    Science.gov (United States)

    Oudrari, Hassan; McIntire, Jeff; Xiong, Xiaoxiong; Butler, James; Efremova, Boryana; Ji, Qiang; Lee, Shihyan; Schwarting, Tom

    2015-09-01

    The Visible Infrared Imaging Radiometer Suite (VIIRS) on-board the first Joint Polar Satellite System (JPSS) completed its sensor level testing on December 2014. The JPSS-1 (J1) mission is scheduled to launch in December 2016, and will be very similar to the Suomi-National Polar-orbiting Partnership (SNPP) mission. VIIRS instrument was designed to provide measurements of the globe twice daily. It is a wide-swath (3,040 km) cross-track scanning radiometer with spatial resolutions of 370 and 740 m at nadir for imaging and moderate bands, respectively. It covers the wavelength spectrum from reflective to long-wave infrared through 22 spectral bands [0.412 μm to 12.01 μm]. VIIRS observations are used to generate 22 environmental data products (EDRs). This paper will briefly describe J1 VIIRS characterization and calibration performance and methodologies executed during the pre-launch testing phases by the independent government team, to generate the at-launch baseline radiometric performance, and the metrics needed to populate the sensor data record (SDR) Look-Up-Tables (LUTs). This paper will also provide an assessment of the sensor pre-launch radiometric performance, such as the sensor signal to noise ratios (SNRs), dynamic range, reflective and emissive bands calibration performance, polarization sensitivity, bands spectral performance, response-vs-scan (RVS), near field and stray light responses. A set of performance metrics generated during the pre-launch testing program will be compared to the SNPP VIIRS pre-launch performance.

  4. Inter-Band Radiometric Comparison and Calibration of ASTER Visible and Near-Infrared Bands

    Directory of Open Access Journals (Sweden)

    Kenta Obata

    2015-11-01

    Full Text Available The present study evaluates inter-band radiometric consistency across the Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER visible and near-infrared (VNIR bands and develops an inter-band calibration algorithm to improve radiometric consistency. Inter-band radiometric comparison of current ASTER data shows a root mean square error (RMSE of 3.8%–5.7% among radiance outputs of spectral bands due primarily to differences between calibration strategies of the NIR band for nadir-looking (Band 3N and the other two bands (green and red bands, corresponding to Bands 1 and 2. An algorithm for radiometric calibration of Bands 2 and 3N with reference to Band 1 is developed based on the band translation technique and is used to obtain new radiometric calibration coefficients (RCCs for sensor sensitivity degradation. The systematic errors between radiance outputs are decreased by applying the derived RCCs, which result in reducing the RMSE from 3.8%–5.7% to 2.2%–2.9%. The remaining errors are approximately equal to or smaller than the intrinsic uncertainties of inter-band calibration derived by sensitivity analysis. Improvement of the radiometric consistency would increase the accuracy of band algebra (e.g., vegetation indices and its application. The algorithm can be used to evaluate inter-band radiometric consistency, as well as for the calibration of other sensors.

  5. Radiometric Normalization of Large Airborne Image Data Sets Acquired by Different Sensor Types

    Science.gov (United States)

    Gehrke, S.; Beshah, B. T.

    2016-06-01

    Generating seamless mosaics of aerial images is a particularly challenging task when the mosaic comprises a large number of im-ages, collected over longer periods of time and with different sensors under varying imaging conditions. Such large mosaics typically consist of very heterogeneous image data, both spatially (different terrain types and atmosphere) and temporally (unstable atmo-spheric properties and even changes in land coverage). We present a new radiometric normalization or, respectively, radiometric aerial triangulation approach that takes advantage of our knowledge about each sensor's properties. The current implementation supports medium and large format airborne imaging sensors of the Leica Geosystems family, namely the ADS line-scanner as well as DMC and RCD frame sensors. A hierarchical modelling - with parameters for the overall mosaic, the sensor type, different flight sessions, strips and individual images - allows for adaptation to each sensor's geometric and radiometric properties. Additional parameters at different hierarchy levels can compensate radiome-tric differences of various origins to compensate for shortcomings of the preceding radiometric sensor calibration as well as BRDF and atmospheric corrections. The final, relative normalization is based on radiometric tie points in overlapping images, absolute radiometric control points and image statistics. It is computed in a global least squares adjustment for the entire mosaic by altering each image's histogram using a location-dependent mathematical model. This model involves contrast and brightness corrections at radiometric fix points with bilinear interpolation for corrections in-between. The distribution of the radiometry fixes is adaptive to each image and generally increases with image size, hence enabling optimal local adaptation even for very long image strips as typi-cally captured by a line-scanner sensor. The normalization approach is implemented in HxMap software. It has been

  6. Landsat-7 ETM+ radiometric stability and absolute calibration

    Science.gov (United States)

    Markham, B.L.; Barker, J.L.; Barsi, J.A.; Kaita, E.; Thome, K.J.; Helder, D.L.; Palluconi, Frank Don; Schott, J.R.; Scaramuzza, P.; ,

    2002-01-01

    Launched in April 1999, the Landsat-7 ETM+ instrument is in its fourth year of operation. The quality of the acquired calibrated imagery continues to be high, especially with respect to its three most important radiometric performance parameters: reflective band instrument stability to better than ??1%, reflective band absolute calibration to better than ??5%, and thermal band absolute calibration to better than ??0.6 K. The ETM+ instrument has been the most stable of any of the Landsat instruments, in both the reflective and thermal channels. To date, the best on-board calibration source for the reflective bands has been the Full Aperture Solar Calibrator, which has indicated changes of at most -1.8% to -2.0% (95% C.I.) change per year in the ETM+ gain (band 4). However, this change is believed to be caused by changes in the solar diffuser panel, as opposed to a change in the instrument's gain. This belief is based partially on ground observations, which bound the changes in gain in band 4 at -0.7% to +1.5%. Also, ETM+ stability is indicated by the monitoring of desert targets. These image-based results for four Saharan and Arabian sites, for a collection of 35 scenes over the three years since launch, bound the gain change at -0.7% to +0.5% in band 4. Thermal calibration from ground observations revealed an offset error of +0.31 W/m 2 sr um soon after launch. This offset was corrected within the U. S. ground processing system at EROS Data Center on 21-Dec-00, and since then, the band 6 on-board calibration has indicated changes of at most +0.02% to +0.04% (95% C.I.) per year. The latest ground observations have detected no remaining offset error with an RMS error of ??0.6 K. The stability and absolute calibration of the Landsat-7 ETM+ sensor make it an ideal candidate to be used as a reference source for radiometric cross-calibrating to other land remote sensing satellite systems.

  7. MISR FIRSTLOOK radiometric camera-by-camera Cloud Mask V001

    Data.gov (United States)

    National Aeronautics and Space Administration — This file contains the FIRSTLOOK Radiometric camera-by-camera Cloud Mask (RCCM) dataset produced using ancillary inputs (RCCT) from the previous time period. It is...

  8. Intra-annual NDVI validation of the Landsat 5 TM radiometric calibration

    Science.gov (United States)

    Chander, G.; Groeneveld, D.P.

    2009-01-01

    Multispectral data from the Landsat 5 (L5) Thematic Mapper (TM) sensor provide the backbone of the extensive archive of moderate‐resolution Earth imagery. Even after more than 24 years of service, the L5 TM is still operational. Given the longevity of the satellite, the detectors have aged and the sensor's radiometric characteristics have changed since launch. The calibration procedures and parameters in the National Land Archive Production System (NLAPS) have also changed with time. Revised radiometric calibrations in 2003 and 2007 have improved the radiometric accuracy of recently processed data. This letter uses the Normalized Difference Vegetation Index (NDVI) as a metric to evaluate the radiometric calibration. The calibration change has improved absolute calibration accuracy, consistency over time, and consistency with Landsat 7 (L7) Enhanced Thematic radiometry and will provide the basis for continued long‐term studies of the Earth's land surfaces.

  9. Signature modelling and radiometric rendering equations in infrared scene simulation systems

    CSIR Research Space (South Africa)

    Willers, CJ

    2011-09-01

    Full Text Available The development and optimisation of modern infrared systems necessitates the use of simulation systems to create radiometrically realistic representations (e.g. images) of infrared scenes. Such simulation systems are used in signature prediction...

  10. Simultaneous Inflight Spectral and Radiometric Calibration Validation of AVRIS and HYDICE Over Lunar Lake, Nevada

    Science.gov (United States)

    Chrien, Thomas; Green, Robert; Chovit, Chris; Faust, Jessica; Johnson, Howell; Basedow, Robert; Zalewski, Edward; Colwell, John

    1995-01-01

    An experiment to check the spectral and radiometric calibration of two sensors--the airborne visible/infrared imaging spectromenter (AVRIS) and the Hyperspectral digital image collection experiment (HYDICE)--is described.

  11. Radiometric Measurements of Slant Path Attenuation in the V/W Bands

    Science.gov (United States)

    2014-09-01

    MM-YYYY) SEPTEMBER 2014 2. REPORT TYPE INTERIM TECHNICAL REPORT 3. DATES COVERED (From - To) AUG 2012 – APR 2014 4. TITLE AND SUBTITLE RADIOMETRIC ... RADIOMETRIC MEASUREMENTS OF SLANT PATH ATTENUATION IN THE V/W BANDS SEPTEMBER 2014 INTERIM TECHNICAL REPORT APPROVED...information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. 1. REPORT DATE (DD

  12. An Infrared Focal Plane Array Camera System for Stereo-based Radiometric Imaging

    Science.gov (United States)

    1999-01-01

    Plane Array Calibrated System ( FPACS ) utilizes several features to help ensure radiometric accuracy. Some features help minimize unwanted radiation...possible, and beyond that, the FPACS design ensures that the operator is made aware when operating conditions may lead to radiometric inaccuracies. Primary...components of FPACS are illustrated in Fig. 1. Components are 1) Optics, 2) FPA/Dewar, 3) Camera Electronics, 4) Pan & Tilt platform, and 4) Windows

  13. Optimized mapping of radiometric quantities into OpenGL

    Science.gov (United States)

    Lorenzo, Maximo; Jacobs, Eddie L.; Moulton, J. R., Jr.; Liu, Jesse

    1999-07-01

    Physically realistic synthesis of FLIR imagery requires intensive phenomenology calculations of the spectral band thermal emission and reflection from scene elements in the database. These calculations predict the heat conduction, convection, and radiation exchange between scene elements and the environment. Balancing this requirement is the need for imagery to be presented to a display in a timely fashion, often in real time. In order to support these conflicting requirements, some means of overcoming the gap between real time and high fidelity must be achieved. Over the past several years, the US Army Night Vision and Electronic Sensors Directorate (NVESD) has been developing a real-time forward looking infrared sensor simulation known as Paint the Night (PTN). As part of this development, NVESD has explored schemes for optimizing signature models and for mapping model radiometric output into parameters compatible with OpenGL, real-time rendering architectures. Relevant signature and mapping optimization issues are discussed, and a current NVESD PTN real-time implementation scheme is presented.

  14. Landsat-8 Operational Land Imager Radiometric Calibration and Stability

    Directory of Open Access Journals (Sweden)

    Brian Markham

    2014-12-01

    Full Text Available The Landsat-8 Operational Land Imager (OLI was radiometrically calibrated prior to launch in terms of spectral radiance, using an integrating sphere source traceable to National Institute of Standards and Technology (NIST standards of spectral irradiance. It was calibrated on-orbit in terms of reflectance using diffusers characterized prior to launch using NIST traceable standards. The radiance calibration was performed with an uncertainty of ~3%; the reflectance calibration to an uncertainty of ~2%. On-orbit, multiple calibration techniques indicate that the sensor has been stable to better than 0.3% to date, with the exception of the shortest wavelength band, which has degraded about 1.0%. A transfer to orbit experiment conducted using the OLI’s heliostat-illuminated diffuser suggests that some bands increased in sensitivity on transition to orbit by as much as 5%, with an uncertainty of ~2.5%. On-orbit comparisons to other instruments and vicarious calibration techniques show the radiance (without a transfer to orbit adjustment, and reflectance calibrations generally agree with other instruments and ground measurements to within the uncertainties. Calibration coefficients are provided with the data products to convert to either radiance or reflectance units.

  15. NERO: General concept of a NEO radiometric observatory

    Science.gov (United States)

    Cellino, A.; Somma, R.; Tommasi, L.; Paolinetti, R.; Muinonen, K.; Virtanen, J.; Tedesco, E. F.

    NERO (Near-Earth Objects Radiometric Observatory) is one of the six studies for possible missions dedicated to near-Earth objects, that were funded by the ESA in 2002-2003. NERO is a further development of previous studies already submitted to ESA (Sysiphos,Spaceguard-1). The general concept is that a small satellite equipped with both a CCD for visible wavelengths and an array for thermal IR measurements around 10 microns would be an ideal platform for simultaneously obtaining two of the major objectives of current NEO science, namely the physical characterization of the objects and the discovery of NEOs which are difficult to detect because they have orbits entirely or partly interior to the Earth's orbit. The NERO study included a comprehensive analysis of the advantages and drawbacks of different orbital options for the satellite (including L2 of Earth and L2 of Venus) and a preliminary simulation of the effectiveness in deriving reliable orbits of the newly detected objects. The main results of this study, including also a preliminary design of the payload (optics, detectors, cooling system, etc.) are briefly summarized.

  16. Radiometric dating of sediment records in European mountain lakes

    Directory of Open Access Journals (Sweden)

    Peter G. APPLEBY

    2000-09-01

    Full Text Available Sediment cores from seven European mountain lakes collected as part of a study of palaeolimnogical records of climate change (the MOLAR project were dated radiometrically by 210Pb. In spite of the remote locations, only one site recorded more or less uniform sediment accumulation throughout the past 150 years. At three further sites the 210Pb record indicated uniform sedimentation up until ca 1950 but significant increases since then. Stratigraphic dates based on records of fallout 137Cs and 241Am showed that 210Pb supply rates to these core sites had nonetheless remained relatively constant and that the sediments could be dated by the CRS model. At the remaining sites there were indications of episodic changes in both sedimentation rates and 210Pb supply rates. Since the changes were not in proportion, neither of the simple dating models (CRS or CIC was applicable. Using the 137Cs and 241Am stratigraphic dates as reference points it was however possible to construct a realistic chronology for these cores by applying the CRS model piecewise to each time-bounded section.

  17. Selection of chemotherapy for patient treatment utilizing a radiometric versus a cloning system.

    Science.gov (United States)

    Von Hoff, D D; Forseth, B J; Turner, J N; Clark, G M; Warfel, L E

    1986-01-01

    From the 1950s to the 1970s, a number of in vitro systems that measured inhibition of glucose metabolism were used to predict the responsiveness of patients' tumors to chemotherapy. In vitro-in vivo correlations were excellent, with true positive predictions ranging from 68% to 96% and true negative predictions of 95% to 100%. The radiometric system is a new in vitro technique that measures the conversion of 14C-glucose to 14CO2. The system already has been utilized to screen prospective new antineoplastic agents for cytotoxicity. The present study was undertaken to determine if the radiometric system might be used to predict correctly the responsiveness of an individual patient's tumor to single-agent or combination-agent chemotherapy. Fifty-six tumor specimens were divided and tested for drug sensitivity in the radiometric system and a conventional human tumor clonning system. Overall, there was a significant correlation between in vitro and in vivo results for the conventional cloning system (P = 0.03). However, there was no significant relationship between in vitro and in vivo results for the radiometric system. The radiometric system consistently failed to predict the tumor's clinical sensitivity to single agents. A radiometric system is not useful in predicting the responsiveness of a patient's tumor to single agent chemotherapy and is not a replacement for the more biologically attractive human tumor cloning system.

  18. Evaluation of relative radiometric correction techniques on Landsat 8 OLI sensor data

    Science.gov (United States)

    Novelli, Antonio; Caradonna, Grazia; Tarantino, Eufemia

    2016-08-01

    The quality of information derived from processed remotely sensed data may depend upon many factors, mostly related to the extent data acquisition is influenced by atmospheric conditions, topographic effects, sun angle and so on. The goal of radiometric corrections is to reduce such effects in order enhance the performance of change detection analysis. There are two approaches to radiometric correction: absolute and relative calibrations. Due to the large amount of free data products available, absolute radiometric calibration techniques may be time consuming and financially expensive because of the necessary inputs for absolute calibration models (often these data are not available and can be difficult to obtain). The relative approach to radiometric correction, known as relative radiometric normalization, is preferred with some research topics because no in situ ancillary data, at the time of satellite overpasses, are required. In this study we evaluated three well known relative radiometric correction techniques using two Landsat 8 - OLI scenes over a subset area of the Apulia Region (southern Italy): the IR-MAD (Iteratively Reweighted Multivariate Alteration Detection), the HM (Histogram Matching) and the DOS (Dark Object Subtraction). IR-MAD results were statistically assessed within a territory with an extremely heterogeneous landscape and all computations performed in a Matlab environment. The panchromatic and thermal bands were excluded from the comparisons.

  19. MSFIA-LOV system for {sup 226}Ra isolation and pre-concentration from water samples previous radiometric detection

    Energy Technology Data Exchange (ETDEWEB)

    Rodríguez, Rogelio [Environmental Radioactivity Laboratory (LaboRA), University of the Balearic Islands, Cra. Valldemossa km 7.5, 07122, Palma (Spain); Environment and Energy Department, Advanced Materials Research Center (CIMAV) S.C., Miguel de Cervantes 120, Chihuahua, Chih. 31136 (Mexico); Borràs, Antoni [Environmental Radioactivity Laboratory (LaboRA), University of the Balearic Islands, Cra. Valldemossa km 7.5, 07122, Palma (Spain); Leal, Luz [Environment and Energy Department, Advanced Materials Research Center (CIMAV) S.C., Miguel de Cervantes 120, Chihuahua, Chih. 31136 (Mexico); Cerdà, Víctor [Department of Chemistry, University of the Balearic Islands, Cra. Valldemossa km 7.5, 07122, Palma (Spain); Ferrer, Laura, E-mail: laura.ferrer@uib.es [Environmental Radioactivity Laboratory (LaboRA), University of the Balearic Islands, Cra. Valldemossa km 7.5, 07122, Palma (Spain)

    2016-03-10

    An automatic system based on multisyringe flow injection analysis (MSFIA) and lab-on-valve (LOV) flow techniques for separation and pre-concentration of {sup 226}Ra from drinking and natural water samples has been developed. The analytical protocol combines two different procedures: the Ra adsorption on MnO{sub 2} and the BaSO{sub 4} co-precipitation, achieving more selectivity especially in water samples with low radium levels. Radium is adsorbed on MnO{sub 2} deposited on macroporous of bead cellulose. Then, it is eluted with hydroxylamine to transform insoluble MnO{sub 2} to soluble Mn(II) thus freeing Ra, which is then coprecipitated with BaSO{sub 4}. The {sup 226}Ra can be directly detected in off-line mode using a low background proportional counter (LBPC) or through a liquid scintillation counter (LSC), after performing an on-line coprecipitate dissolution. Thus, the versatility of the proposed system allows the selection of the radiometric detection technique depending on the detector availability or the required response efficiency (sample number vs. response time and limit of detection). The MSFIA-LOV system improves the precision (1.7% RSD), and the extraction frequency (up to 3 h{sup −1}). Besides, it has been satisfactorily applied to different types of water matrices (tap, mineral, well and sea water). The {sup 226}Ra minimum detectable activities (LSC: 0.004 Bq L{sup −1}; LBPC: 0.02 Bq L{sup −1}) attained by this system allow to reach the guidance values proposed by the relevant international agencies e.g. WHO, EPA and EC. - Highlights: • Automatic, rapid and selective method for {sup 226}Ra extraction/pre-concentration from water. • MSFIA-LOV system performs a sample clean-up prior to {sup 226}Ra radiometric detection. • {sup 226}Ra sample preparation allows using two radiometric detectors (LBPC and LSC). • Environmental levels of {sup 226}Ra are easily quantified. • High sensitivity and selectivity are achieved, reaching the

  20. Precise quantitation of PAIgG: A new radiometric microtechnique

    Energy Technology Data Exchange (ETDEWEB)

    Schwartz, K.A.; Gauger, J.A.; Davis, J.M. (Michigan State Univ., East Lansing (USA))

    1990-03-01

    We report the development of a radiometric assay for platelet-bound IgG that is both sensitive and quantitative. The assay utilized 96-well millititer plates incorporating a 0.2 microns filter membrane in the bottom. A 125I-labeled monoclonal antihuman IgG, as a secondary antibody, detected the platelet-bound human IgG. Since 5 x 10(6) platelets were used for each assay, tests for platelet-bound IgG can be performed on persons with severe thrombocytopenia. For the detection of circulating antiplatelet alloantibodies, as little as 10 microliters of platelet-free plasma per assay is required. Antiplatelet IgG was quantitated by using anti-PIA1 antibody that was purified with affinity and elution and DEAE chromatography. This purified antiplatelet antibody was labeled with 125I and was used to determine the binding ratio of secondary antibody to primary antibody. Under our standard conditions, this ratio was found to be stable at approximately 0.35 over the sensitivity range of the assay. The assay can detect approximately 200 molecules of human IgG per platelet (0.1 ng of secondary antibody bound per 5 x 10(6) platelets). It has a linear range from 0 to 7,000 molecules per platelet. Quantitation of anti-PIA1 binding for platelets stored for up to 6 months under refrigeration showed no change in number of PIA1 binding sites. Clinical studies showed that 18 of 19 ITP patients had an increased number of IgG molecules per platelet as did patients with malignancy and drug-induced immune thrombocytopenia. Patients who had received multiple platelet transfusions had antiplatelet antibody in their plasma. Normal amounts of PAIgG were observed in platelets and plasma of patients with nonimmune thrombocytopenia.

  1. Radiometric Cross-Calibration of GF-4 in Multispectral Bands

    Directory of Open Access Journals (Sweden)

    Aixia Yang

    2017-03-01

    Full Text Available The GaoFen-4 (GF-4, launched at the end of December 2015, is China’s first high-resolution geostationary optical satellite. A panchromatic and multispectral sensor (PMS is onboard the GF-4 satellite. Unfortunately, the GF-4 has no onboard calibration assembly, so on-orbit radiometric calibration is required. Like the charge-coupled device (CCD onboard HuanJing-1 (HJ or the wide field of view sensor (WFV onboard GaoFen-1 (GF-1, GF-4 also has a wide field of view, which provides challenges for cross-calibration with narrow field of view sensors, like the Landsat series. A new technique has been developed and used to calibrate HJ-1/CCD and GF-1/WFV, which is verified viable. The technique has three key steps: (1 calculate the surface using the bi-directional reflectance distribution function (BRDF characterization of a site, taking advantage of its uniform surface material and natural topographic variation using Landsat Enhanced Thematic Mapper Plus (ETM+/Operational Land Imager (OLI imagery and digital elevation model (DEM products; (2 calculate the radiance at the top-of-the atmosphere (TOA with the simulated surface reflectance using the atmosphere radiant transfer model; and (3 fit the calibration coefficients with the TOA radiance and corresponding Digital Number (DN values of the image. This study attempts to demonstrate the technique is also feasible to calibrate GF-4 multispectral bands. After fitting the calibration coefficients using the technique, extensive validation is conducted by cross-validation using the image pairs of GF-4/PMS and Landsat-8/OLI with similar transit times and close view zenith. The validation result indicates a higher accuracy and frequency than that given by the China Centre for Resources Satellite Data and Application (CRESDA using vicarious calibration. The study shows that the new technique is also quite feasible for GF-4 multispectral bands as a routine long-term procedure.

  2. An Overview of MODIS Radiometric Calibration and Characterization

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    The Moderate Resolution Imaging Spectroradiometer (MODIS) is one of the key instruments for NASA's Earth Observing System (EOS), currently operating on both the Terra and Aqua satellites. The MODIS is a major advance over the previous generation of sensors in terms of its spectral, spatial, and temporal resolutions. It has 36 spectral bands: 20 reflective solar bands (RSB) with center wavelengths from 0.41 to 2.1μm and 16 thermal emissive bands (TEB) with center wavelengths from 3.7 to 14.4μm,making observations at three spatial resolutions: 250 m (bands 1-2), 500 m (bands 3-7), and 1km (bands 8-36). MODIS is a cross-track scanning radiometer with a wide field-of-view, providing a complete global coverage of the Earth in less than 2 days. Both Terra and Aqua MODIS went through extensive pre-launch calibration and characterization at various levels. In orbit, the calibration and characterization tasks are performed using its on-board calibrators (OBCs) that include a solar diffuser (SD) and a solar diffuser stability monitor (SDSM), a v-grooved flat panel blackbody (BB), and a spectro-radiometric calibration assembly (SRCA). In this paper, we present an overview of MODIS calibration and characterization activities, methodologies, and lessons learned from pre-launch characterization and in-orbit operation. Key issues discussed in this paper include in-orbit efforts of monitoring the noise characteristics of the detectors,tracking the solar diffuser and optics degradations, and updating the sensor's response versus scan angle.The experiences and lessons learned through MODIS have played and will continue to play major roles in the design and characterization of future sensors.

  3. Landsat-7 EMT+ On-Orbit Radiometric Calibration

    Science.gov (United States)

    Markham, Brian L.; Barker, J. L.; Kaita, E.; Seiferth, J.; Morfitt, Ron

    1999-01-01

    Landsat-7 was launched on April 15, 1999 and completed its on orbit initialization and verification period on June 28, 1999. The ETM+ payload is similar to the TM sensors on previous Landsat satellites and incorporates two new devices to improve its absolute radiometric calibration. The Full Aperture Solar Calibrator (FASC) is a deployable diffuser panel. This device has been deployed 9 times to date, with a normal deployment schedule of once per month. The initial analysis of the FASC data has given absolute calibration results within 5% of the prelaunch integrating sphere calibrations and a range of variation of 2% between dates. The Partial Aperture Solar Calibrator (PASC), is a set of auxiliary optics that allows the ETM+ to view the sun through a reduced aperture. Data have normally been acquired on a daily basis with the PASC. Initial results with the PASC were encouraging, despite some unexpected saturation in the shortest wavelength band. The response of the ETM+ short wavelength (silicon) bands to the PASC increased initially and has begun to decrease in some of these bands. The longer wavelength (InSb) bands have shown up to 30% oscillations that vary between detectors within the band. Studies are ongoing to better characterize the response to the PASC. The ETM+ also incorporates an internal calibrator (IC), a shutter that oscillates in front of the focal plane that directs light from the internal calibrator lamps to the focal plane. The responses to this device are also varying, though differently than the PASC results. Both the IC and PASC results are attributable to the calibration devices as opposed to the ETM+ itself.

  4. Initial Radiometric Characteristics of KOMPSAT-3A Multispectral Imagery Using the 6S Radiative Transfer Model, Well-Known Radiometric Tarps, and MFRSR Measurements

    Directory of Open Access Journals (Sweden)

    Jong-Min Yeom

    2017-02-01

    Full Text Available On-orbit radiometric characterization of the multispectral (MS imagery of the Korea Aerospace Research Institute (KARI’s Korea Multi-Purpose Satellite-3A (KOMPSAT-3A, which was launched on 25 March 2015, was conducted to provide quantitative radiometric information about KOMPSAT-3A. During the in-orbit test (IOT, vicarious radiometric calibration of KOMPSAT-3A was performed using the Second Simulation of a Satellite Signal in the Solar Spectrum (6S radiative transfer model. The characteristics of radiometric tarps, the atmospheric optical depth from multi-filter rotating shadowband radiometer (MFRSR measurements, and sun–sensor–geometry were carefully considered, in order to calculate the exact top of atmosphere (TOA radiance received by KOMPSAT-3A MS bands. In addition, the bidirectional reflectance distribution function (BRDF behaviors of the radiometric tarps were measured in the laboratory with a two-dimensional hyperspectral gonioradiometer, to compensate for the geometry discrepancy between the satellite and the ASD FieldSpec® 3 spectroradiometer. The match-up datasets between the TOA radiance and the digital number (DN from KOMPSAT-3A were used to determine DN-to-radiance conversion factors, based on linear least squares fitting for two field campaigns. The final results showed that the R2 values between the observed and simulated radiances for the blue, green, red, and near-infrared (NIR bands, are greater than 0.998. An approximate error budget analysis for the vicarious calibration of KOMPSAT-3A showed an error of less than 6.8%. When applying the laboratory-based BRDF correction to the case of higher viewing zenith angle geometry, the gain ratio was improved, particularly for the blue (1.3% and green (1.2% bands, which exhibit high sensitivity to the BRDF of radiometric tarps during the backward-scattering phase. The calculated gain ratio between the first and second campaigns showed a less than 5% discrepancy, indicating that

  5. English/Russian terminology on radiometric calibration of space-borne optoelectronic sensors

    Science.gov (United States)

    Privalsky, V.; Zakharenkov, V.; Humpherys, T.; Sapritsky, V.; Datla, R.

    The efficient use of data acquired through exo-atmospheric observations of the Earth within the framework of existing and newly planned programs requires a unique understanding of respective terms and definitions. Yet, the last large-scale document on the subject - The International Electrotechnical Vocabulary - had been published 18 years ago. This lack of a proper document, which would reflect the changes that had occurred in the area since that time, is especially detrimental to the developing international efforts aimed at global observations of the Earth from space such as the Global Earth Observations Program proposed by the U.S.A. at the 2003 WMO Congress. To cover this gap at least partially, a bi-lingual explanatory dictionary of terms and definitions in the area of radiometric calibration of space-borne IR sensors is developed. The objectives are to produce a uniform terminology for the global space-borne observations of the Earth, establish a unique understanding of terms and definitions by the radiometric communities, including a correspondence between the Russian and American terms and definitions, and to develop a formal English/Russian reference dictionary for use by scientists and engineers involved in radiometric observations of the Earth from space. The dictionary includes close to 400 items covering basic concepts of geometric, wave and corpuscular optics, remote sensing technologies, and ground-based calibration as well as more detailed treatment of terms and definitions in the areas of radiometric quantities, symbols and units, optical phenomena and optical properties of objects and media, and radiometric systems and their properties. The dictionary contains six chapters: Basic Concepts, Quantities, Symbols, and Units, Optical phenomena, Optical characteristics of surfaces and media, Components of Radiometric Systems, Characteristics of radiometric system components, plus English/Russian and Russian/Inglish indices.

  6. Experimental methods of indoor millimeter-wave radiometric imaging for personnel concealed contraband detection

    Science.gov (United States)

    Hu, Taiyang; Xiao, Zelong; Li, Hao; Lv, Rongchuan; Lu, Xuan

    2014-11-01

    The increasingly emerging terrorism attacks and violence crimes around the world have posed severe threats to public security, so carrying out relevant research on advanced experimental methods of personnel concealed contraband detection is crucial and meaningful. All of the advantages of imaging covertly, avoidance of interference with other systems, intrinsic property of being safe to persons under screening , and the superior ability of imaging through natural or manmade obscurants, have significantly combined to enable millimeter-wave (MMW) radiometric imaging to offer great potential in personnel concealed contraband detection. Based upon the current research status of MMW radiometric imaging and urgent demands of personnel security screening, this paper mainly focuses on the experimental methods of indoor MMW radiometric imaging. The reverse radiation noise resulting from super-heterodyne receivers seriously affects the image experiments carried out at short range, so both the generation mechanism and reducing methods of this noise are investigated. Then, the benefit of sky illumination no longer exists for the indoor radiometric imaging, and this leads to the decrease in radiometric temperature contrast between target and background. In order to enhance the radiometric temperature contrast for improving indoor imaging performance, the noise illumination technique is adopted in the indoor imaging scenario. In addition, the speed and accuracy of concealed contraband detection from acquired MMW radiometric images are usually restricted to the deficiencies in traditional artificial interpretation by security inspectors, thus an automatic recognition and location algorithm by integrating improved Fuzzy C-means clustering with moment invariants is put forward. A series of original results are also presented to demonstrate the significance and validity of these methods.

  7. Improved Thermal-Vacuum Compatible Flat Plate Radiometric Souce for System-Level Testing of Optical Sensors

    Science.gov (United States)

    Schwarz, Mark A.; Kent, Craig J.; Bousquet, Robert; Brown, Steven W.

    2015-01-01

    This work describes the development of an improved vacuum compatible flat plate radiometric source used for characterizing and calibrating remote optical sensors, in situ, throughout their testing period. The original flat plate radiometric source was developed for use by the VIIRS instrument during the NPOESS Preparatory Project (NPP). Following this effort, the FPI has had significant upgrades in order to improve both the radiometric throughput and uniformity. Results of the VIIRS testing with the reconfigured FPI are reported and discussed.

  8. RADIOMETRIC NORMALIZATION OF LARGE AIRBORNE IMAGE DATA SETS ACQUIRED BY DIFFERENT SENSOR TYPES

    Directory of Open Access Journals (Sweden)

    S. Gehrke

    2016-06-01

    Full Text Available Generating seamless mosaics of aerial images is a particularly challenging task when the mosaic comprises a large number of im-ages, collected over longer periods of time and with different sensors under varying imaging conditions. Such large mosaics typically consist of very heterogeneous image data, both spatially (different terrain types and atmosphere and temporally (unstable atmo-spheric properties and even changes in land coverage. We present a new radiometric normalization or, respectively, radiometric aerial triangulation approach that takes advantage of our knowledge about each sensor’s properties. The current implementation supports medium and large format airborne imaging sensors of the Leica Geosystems family, namely the ADS line-scanner as well as DMC and RCD frame sensors. A hierarchical modelling – with parameters for the overall mosaic, the sensor type, different flight sessions, strips and individual images – allows for adaptation to each sensor’s geometric and radiometric properties. Additional parameters at different hierarchy levels can compensate radiome-tric differences of various origins to compensate for shortcomings of the preceding radiometric sensor calibration as well as BRDF and atmospheric corrections. The final, relative normalization is based on radiometric tie points in overlapping images, absolute radiometric control points and image statistics. It is computed in a global least squares adjustment for the entire mosaic by altering each image’s histogram using a location-dependent mathematical model. This model involves contrast and brightness corrections at radiometric fix points with bilinear interpolation for corrections in-between. The distribution of the radiometry fixes is adaptive to each image and generally increases with image size, hence enabling optimal local adaptation even for very long image strips as typi-cally captured by a line-scanner sensor. The normalization approach is implemented in

  9. Vicarious absolute radiometric calibration of GF-2 PMS2 sensor using permanent artificial targets in China

    Science.gov (United States)

    Liu, Yaokai; Li, Chuanrong; Ma, Lingling; Wang, Ning; Qian, Yonggang; Tang, Lingli

    2016-10-01

    GF-2, launched on August 19 2014, is one of the high-resolution land resource observing satellite of the China GF series satellites plan. The radiometric performance evaluation of the onboard optical pan and multispectral (PMS2) sensor of GF-2 satellite is very important for the further application of the data. And, the vicarious absolute radiometric calibration approach is one of the most useful way to monitor the radiometric performance of the onboard optical sensors. In this study, the traditional reflectance-based method is used to vicarious radiometrically calibrate the onboard PMS2 sensor of GF-2 satellite using three black, gray and white reflected permanent artificial targets located in the AOE Baotou site in China. Vicarious field calibration campaign were carried out in the AOE-Baotou calibration site on 22 April 2016. And, the absolute radiometric calibration coefficients were determined with in situ measured atmospheric parameters and surface reflectance of the permanent artificial calibration targets. The predicted TOA radiance of a selected desert area with our determined calibrated coefficients were compared with the official distributed calibration coefficients. Comparison results show a good consistent and the mean relative difference of the multispectral channels is less than 5%. Uncertainty analysis was also carried out and a total uncertainty with 3.87% is determined of the TOA radiance.

  10. RADIOMETRIC CALIBRATION OF MARS HiRISE HIGH RESOLUTION IMAGERY BASED ON FPGA

    Directory of Open Access Journals (Sweden)

    Y. Hou

    2016-06-01

    Full Text Available Due to the large data amount of HiRISE imagery, traditional radiometric calibration method is not able to meet the fast processing requirements. To solve this problem, a radiometric calibration system of HiRISE imagery based on field program gate array (FPGA is designed. The montage gap between two channels caused by gray inconsistency is removed through histogram matching. The calibration system is composed of FPGA and DSP, which makes full use of the parallel processing ability of FPGA and fast computation as well as flexible control characteristic of DSP. Experimental results show that the designed system consumes less hardware resources and the real-time processing ability of radiometric calibration of HiRISE imagery is improved.

  11. Preparation of a new autonomous instrumented radiometric calibration site: Gobabeb, Namib Desert

    Science.gov (United States)

    Greenwell, Claire; Bialek, Agnieszka; Marks, Amelia; Woolliams, Emma; Berthelot, Béatrice; Meygret, Aimé; Marcq, Sébastien; Bouvet, Marc; Fox, Nigel

    2015-10-01

    A new permanently instrumented radiometric calibration site for high/medium resolution imaging satellite sensors is currently under development, focussing on the visible and near infra-red parts of the spectrum. The site will become a European contribution to the Committee on Earth Observation Satellites (CEOS) initiative RadCalNet (Radiometric Calibration Network). The exact location of the permanent monitoring instrumentation will be defined following the initial site characterisation. The new ESA/CNES RadCalNet site will have a robust uncertainty budget and its data fully SI traceable through detailed characterisation and calibration by NPL of the instruments and artefacts to be used on the site. This includes a CIMEL sun photometer (the permanent instrumentation) an ASD FieldSpec spectroradiometer, Gonio Radiometric Spectrometer System (GRASS), and reference reflectance standards.

  12. Inflight Radiometric Calibration of New Horizons' Multispectral Visible Imaging Camera (MVIC)

    CERN Document Server

    Howett, C J A; Olkin, C B; Reuter, D C; Ennico, K; Grundy, W M; Graps, A L; Harrison, K P; Throop, H B; Buie, M W; Lovering, J R; Porter, S B; Weaver, H A; Young, L A; Stern, S A; Beyer, R A; Binzell, R P; Buratti, B J; Cheng, A F; Cook, J C; Cruikshank, D P; Ore, C M Dalle; Earle, A M; Jennings, D E; Linscott, I R; Lunsford, A W; Parker, J Wm; Phillippe, S; Protopapa, S; Quirico, E; Schenk, P M; Schmitt, B; Singer, K N; Spencer, J R; Stansberry, J A; Tsang, C C C; Weigle, G E; Verbiscer, A J

    2016-01-01

    We discuss two semi-independent calibration techniques used to determine the in-flight radiometric calibration for the New Horizons' Multi-spectral Visible Imaging Camera (MVIC). The first calibration technique compares the observed stellar flux to modeled values. The difference between the two provides a calibration factor that allows the observed flux to be adjusted to the expected levels for all observations, for each detector. The second calibration technique is a channel-wise relative radiometric calibration for MVIC's blue, near-infrared and methane color channels using observations of Charon and scaling from the red channel stellar calibration. Both calibration techniques produce very similar results (better than 7% agreement), providing strong validation for the techniques used. Since the stellar calibration can be performed without a color target in the field of view and covers all of MVIC's detectors, this calibration was used to provide the radiometric keywords delivered by the New Horizons project...

  13. Evaluation of Two Absolute Radiometric Normalization Algorithms for Pre-processing of Landsat Imagery

    Institute of Scientific and Technical Information of China (English)

    Xu Hanqiu

    2006-01-01

    In order to evaluate radiometric normalization techniques, two image normalization algorithms for absolute radiometric correction of Landsat imagery were quantitatively compared in this paper, which are the Illumination Correction Model proposed by Markham and Irish and the Illumination and Atmospheric Correction Model developed by the Remote Sensing and GIS Laboratory of the Utah State University. Relative noise, correlation coefficient and slope value were used as the criteria for the evaluation and comparison, which were derived from pseudo-invariant features identified from multitemtween the normalized multitemporal images were significantly reduced when the seasons of multitemporal images were different. However, there was no significant difference between the normalized and unnormalized images with a similar seasonal condition. Furthermore, the correction results of two algorithms are similar when the images are relatively clear with a uniform atmospheric condition. Therefore, the radiometric normalization procedures should be carried out if the multitemporal images have a significant seasonal difference.

  14. Absolute Radiometric Calibration of ALS Intensity Data: Effects on Accuracy and Target Classification

    Directory of Open Access Journals (Sweden)

    Anssi Krooks

    2011-11-01

    Full Text Available Radiometric calibration of airborne laser scanning (ALS intensity data aims at retrieving a value related to the target scattering properties, which is independent on the instrument or flight parameters. The aim of a calibration procedure is also to be able to compare results from different flights and instruments, but practical applications are sparsely available, and the performance of calibration methods for this purpose needs to be further assessed. We have studied the radiometric calibration with data from three separate flights and two different instruments using external calibration targets. We find that the intensity data from different flights and instruments can be compared to each other only after a radiometric calibration process using separate calibration targets carefully selected for each flight. The calibration is also necessary for target classification purposes, such as separating vegetation from sand using intensity data from different flights. The classification results are meaningful only for calibrated intensity data.

  15. Lack of clinical relevance in routine final subcultures of radiometrically negative BACTEC blood culture vials

    Energy Technology Data Exchange (ETDEWEB)

    Plorde, J.J.; Carlson, L.G.; Dau, M.E.

    1982-11-01

    During a 38-month period, 10,106 blood specimens were received in the laboratory for culture. These were inoculated into 26,424 vials and processed using the BACTEC radiometric detection system. Of these vials, 1,914 were eventually found to be microbiologically positive. Isolates from 836 vials were judged to be contaminants. In the remaining 1,078 vials, growth was first detected visually or radiometrically in 1,062 and by final subculture in 16. Growth from these sixteen bottles represented 12 clinically significant bacteremic episodes in as many patients. In nine of these episodes, other culture vials from the same patient were positive radiometrically. Therefore, 358 of 361 (99.2%) bacteremic episodes were detected without the benefit of routine final subcultures. The three patients whose bacteremia was missed were diagnosed clinically and placed on appropriate therapy prior to the detection of the bacteremias by final subculture.

  16. Radiometric-microbiologic assay of niacin using Kloeckera brevis: analysis of human blood and food

    Energy Technology Data Exchange (ETDEWEB)

    Guilarte, T.R.; Pravlik, K.

    1983-12-01

    Kloeckera brevis, a yeast, was used as the test organism for the development of a radiometric-microbiologic (RMA) assay for niacin. The assay was determined to be sensitive to the 2 ng niacin per vial level and specific for the biologically active forms of this vitamin. The method was shown to be simple, accurate, and precise in the analysis of niacin in human blood and food. The application of the radiometric technique eliminates some of the problems encountered with conventional turbidimetric-microbiologic assay.

  17. Radiometric survey in mammography: problems and challenges; Levantamento radiometrico em mamografia: problemas e desafios

    Energy Technology Data Exchange (ETDEWEB)

    Navarro, M.V.T.; Navarro, V.C.C.; Garcia, I.F.M.; Ferreira, M.J.; Macedo, E.M., E-mail: navarro@ifba.edu.br [Instituto Federal da Bahia (LABPROSAUD/IFBA), Salvador, BA (Brazil). Laboratorio de Produtos para a Saude

    2015-07-01

    In addition to being mandatory, the radiometric survey is a necessity, especially in the Brazilian reality with the construction of smaller and smaller rooms. However, calibration conditions, the instrumentation and its use, can produce underestimated factors. Measures made at Labprosaud/IFBA, with five different instruments and the ISO N 25 radiation quality, show the possibility of the values presented in the radiometric surveys are underestimated by up to 10 times. The results indicate the need for meters to be calibrated in ISO N qualities, in mammography energy range, in integrated dose mode and exposure times shorter or equal to 1 s. (author)

  18. Radiometric 81Kr dating identifies 120,000-year-old ice at Taylor Glacier, Antarctica

    OpenAIRE

    Buizert, Christo; Baggenstos, Daniel; Jiang, Wei; Purtschert, Roland; Petrenko, Vasilii V.; Lu, Zheng-Tian; Müller, Peter; Kuhl, Tanner; Lee, James,; Severinghaus, Jeffrey P.; Brook, Edward J.

    2014-01-01

    We present the first successful 81Kr-Kr radiometric dating of ancient polar ice. Krypton was extracted from the air bubbles in four ~350 kg polar ice samples from Taylor Glacier in the McMurdo Dry Valleys, Antarctica, and dated using Atom Trap Trace Analysis (ATTA). The 81Kr radiometric ages agree with independent age estimates obtained from stratigraphic dating techniques with a mean absolute age offset of 6 +/- 2.5 ka. Our experimental methods and sampling strategy are validated by 1) 85Kr ...

  19. Airborne lidar and radiometric observations of PBL- and low clouds

    Science.gov (United States)

    Flamant, P. H.; Valentin, R.; Pelon, J.

    1992-01-01

    lidar and narrowbeam IR radiometer is conducted to study the scale integration problem. A good agreement within less than 100 m relies on spatial uniformity and an optically thick layer. In the presence of holes, a discrepancy is observed. This is illustrated in figure 2, displaying as a function of time (1) the lidar signals; (2) the target temperature (either clouds or sea surface) retreived from a narrowbeam IR radiometer, 17 C is the sea surface temperature on that day; and (3) the visible flux, linked to cloud albedo, measured by a pyranometer. In preparation of ASTEX, down- and up-looking measurements where conducted on stratocumulus clouds over the Atlantic Ocean near Quimper in Brittany. Depending on the flight pattern orientation with respect to the wind, the top and bottom cloud morphologies are different. Preliminary results are given on cloud morphology, cloud top PDFs, optical porosity, fractional cloudiness, and comparison of lidar and radiometric measurements.

  20. Calibrated, multiband radiometric measurements of the optical radiation from lightning

    Science.gov (United States)

    Quick, Mason G.

    Calibrated, multiband radiometric measurements of the optical radiation emitted by rocket-triggered lightning (RTL) have been made in the ultraviolet (UV, 200-360 nm), the visible and near infrared (VNIR, 400-1000 nm), and the long wave infrared (LWIR, 8-12 microm) spectral bands. Measurements were recorded from a distance of 198 m at the University of Florida International Center for Lightning Research and Testing (ICLRT) during the summers of 2011 and 2012. The ICLRT provided time-correlated measurements of the current at the base of the RTL channels. Following the onset of a return stroke, the dominant mechanism for the initial rise of the UV and VNIR waveforms was the geometrical growth of the channel in the field-of-view of the sensors. The UV emissions peaked about 0.7 micros after the current peak, with a peak spectral power emitted by the source per unit length of channel of 10 +/- 7 kW/(nm-m) in the UV. The VNIR emissions peaked 0.9 micros after the current peak, with a spectral power of at 7 +/- 4 kW/(nm-m). The LWIR emissions peaked 30-50 micros after the current peak, and the mean peak spectral power was 940 +/- 380 mW/(nm-m), a value that is about 4 orders of magnitude lower than the other spectral band emissions. In some returns strokes the LWIR peak coincides with a secondary maximum in the VNIR band that occurs during a steady decrease in channel current. Examples of the optical waveforms in each spectral band are shown as a function of time and are discussed in the context of the current measured at the channel base. Source power estimates in the VNIR band have a mean and standard deviation of 2.5 +/- 2.2 MW/m and are in excellent agreement with similar estimates of the emission from natural subsequent strokes that remain in a pre-existing channel which have a mean and standard deviation of 2.3 +/- 3.4 MW/m. The peak optical power emitted by RTL in the UV and VNIR bands are observed to be proportional to the square of the peak current at the

  1. Liquids and liquid mixtures

    CERN Document Server

    Rowlinson, J S; Baldwin, J E; Buckingham, A D; Danishefsky, S

    2013-01-01

    Liquids and Liquid Mixtures, Third Edition explores the equilibrium properties of liquids and liquid mixtures and relates them to the properties of the constituent molecules using the methods of statistical thermodynamics. Topics covered include the critical state, fluid mixtures at high pressures, and the statistical thermodynamics of fluids and mixtures. This book consists of eight chapters and begins with an overview of the liquid state and the thermodynamic properties of liquids and liquid mixtures, including vapor pressure and heat capacities. The discussion then turns to the thermodynami

  2. Automatic Radiometric Normalization of Multitemporal Satellite Imagery with the Iteratively Re-weighted MAD Transformation

    DEFF Research Database (Denmark)

    Canty, Morton John; Nielsen, Allan Aasbjerg

    2008-01-01

    A recently proposed method for automatic radiometric normalization of multi- and hyper-spectral imagery based on the invariance property of the Multivariate Alteration Detection (MAD) transformation and orthogonal linear regression is extended by using an iterative re-weighting scheme involving no...

  3. Observations of the moon by the global ozone monitoring experiment: radiometric calibration and lunar albedo

    NARCIS (Netherlands)

    Dobber, M.R.; Goede, A.P.H.; Burrows, J.P.

    1998-01-01

    The Global Ozone Monitoring Experiment (GOME) is a new instrument, which was launched aboard the second European Remoting Sensing satellite ESA-ERS2 in 1995. For its long-term radiometric and spectral calibration the GOME observes the sun and less frequently the moon on a regular basis. These measur

  4. Effects of agrochemicals, ultra violet stabilisers and solar radiation on the radiometric properties of greenhouse films

    Directory of Open Access Journals (Sweden)

    Giuliano Vox

    2013-10-01

    Full Text Available Agrochemicals, based on iron, sulphur and chlorine, generate by products that lead to a degradation of greenhouse films together with a decrease in their mechanical and physical properties. The degradation due to agrochemicals depends on their active principles, method and frequency of application, and greenhouse ventilation. The aim of the research was to evaluate how agrochemical contamination and solar radiation influence the radiometric properties of ethylene-vinyl acetate copolymer greenhouse films by means of laboratory and field tests. The films, manufactured on purpose with the addition of different light stabiliser systems, were exposed to natural outdoor weathering at the experimental farm of the University of Bari (Italy; 41° 05’ N in the period from 2006 to 2008. Each film was tested for two low tunnels: one low tunnel was sprayed from inside with the agrochemicals containing iron, chlorine and sulphur while the other one was not sprayed and served as control. Radiometric laboratory tests were carried out on the new films and on samples taken at the end of the trials. The experimental tests showed that both the natural weathering together with the agrochemicals did not modify significantly the radiometric properties of the films in the solar and in the photosynthetically active radiation wavelength range. Within six months of experimental field tests the variations in these radiometric characteristics were at most 10%. Significant variations, up to 70% of the initial value, were recorded for the stabilised films in the long-wave infrared radiation wavelength range.

  5. Development of a five-hour radiometric serum antibacterial assay for gram-positive cocci

    Energy Technology Data Exchange (ETDEWEB)

    Beckwith, D.G.; Guidon, P.T. Jr.

    1981-03-01

    A preliminary report on a 5-hr radiometric serum antibacterial assay (ABA) for Gram-positive cocci is presented. The method agreed within +- one twofold dilution with static ABA endpoints in 24/26 (92%) of the assays and with cidal ABA end-points in 23/26 (88%) of the assays performed.

  6. New radiometric and petrological constraints on the evolution of the Pichincha volcanic complex (Ecuador)

    NARCIS (Netherlands)

    Robin, Claude; Samaniego, Pablo; Le Pennec, Jean-Luc; Fornari, Michel; Mothes, Patricia; van der Plicht, Johannes; Stix, J.

    2010-01-01

    Fieldwork, radiometric ((40)Ar/(39)Ar and (14)C) ages and whole-rock geochemistry allow a reconstruction of eruptive stages at the active, mainly dacitic, Pichincha Volcanic Complex (PVC), whose eruptions have repeatedly threatened Quito, most recently from 1999 to 2001. After the emplacement of bas

  7. New radiometric and petrological constraints on the evolution of the Pichincha volcanic complex (Ecuador)

    NARCIS (Netherlands)

    Robin, Claude; Samaniego, Pablo; Le Pennec, Jean-Luc; Fornari, Michel; Mothes, Patricia; van der Plicht, Johannes; Stix, J.

    2010-01-01

    Fieldwork, radiometric ((40)Ar/(39)Ar and (14)C) ages and whole-rock geochemistry allow a reconstruction of eruptive stages at the active, mainly dacitic, Pichincha Volcanic Complex (PVC), whose eruptions have repeatedly threatened Quito, most recently from 1999 to 2001. After the emplacement of bas

  8. Radiometric flight results from the HyperSpectral Imager for Climate Science (HySICS)

    Science.gov (United States)

    Kopp, Greg; Smith, Paul; Belting, Chris; Castleman, Zach; Drake, Ginger; Espejo, Joey; Heuerman, Karl; Lanzi, James; Stuchlik, David

    2017-04-01

    Long-term monitoring of the Earth-reflected solar spectrum is necessary for discerning and attributing changes in climate. High radiometric accuracy enables such monitoring over decadal timescales with non-overlapping instruments, and high precision enables trend detection on shorter timescales. The HyperSpectral Imager for Climate Science (HySICS) is a visible and near-infrared spatial/spectral imaging spectrometer intended to ultimately achieve ˜ 0.2 % radiometric accuracies of Earth scenes from space, providing an order-of-magnitude improvement over existing space-based imagers. On-orbit calibrations from measurements of spectral solar irradiances acquired by direct views of the Sun enable radiometric calibrations with superior long-term stability than is currently possible with any manmade spaceflight light source or detector. Solar and lunar observations enable in-flight focal-plane array (FPA) flat-fielding and other instrument calibrations. The HySICS has demonstrated this solar cross-calibration technique for future spaceflight instrumentation via two high-altitude balloon flights. The second of these two flights acquired high-radiometric-accuracy measurements of the ground, clouds, the Earth's limb, and the Moon. Those results and the details of the uncertainty analyses of those flight data are described.

  9. Landsat-8 Operational Land Imager (OLI Radiometric Performance On-Orbit

    Directory of Open Access Journals (Sweden)

    Ron Morfitt

    2015-02-01

    Full Text Available Expectations of the Operational Land Imager (OLI radiometric performance onboard Landsat-8 have been met or exceeded. The calibration activities that occurred prior to launch provided calibration parameters that enabled ground processing to produce imagery that met most requirements when data were transmitted to the ground. Since launch, calibration updates have improved the image quality even more, so that all requirements are met. These updates range from detector gain coefficients to reduce striping and banding to alignment parameters to improve the geometric accuracy. This paper concentrates on the on-orbit radiometric performance of the OLI, excepting the radiometric calibration performance. Topics discussed in this paper include: signal-to-noise ratios that are an order of magnitude higher than previous Landsat missions; radiometric uniformity that shows little residual banding and striping, and continues to improve; a dynamic range that limits saturation to extremely high radiance levels; extremely stable detectors; slight nonlinearity that is corrected in ground processing; detectors that are stable and 100% operable; and few image artifacts.

  10. Landsat-8 Operational Land Imager (OLI) radiometric performance on-orbit

    Science.gov (United States)

    Morfitt, Ron; Barsi, Julia A.; Levy, Raviv; Markham, Brian L.; Micijevic, Esad; Ong, Lawrence; Scaramuzza, Pat; Vanderwerff, Kelly

    2015-01-01

    Expectations of the Operational Land Imager (OLI) radiometric performance onboard Landsat-8 have been met or exceeded. The calibration activities that occurred prior to launch provided calibration parameters that enabled ground processing to produce imagery that met most requirements when data were transmitted to the ground. Since launch, calibration updates have improved the image quality even more, so that all requirements are met. These updates range from detector gain coefficients to reduce striping and banding to alignment parameters to improve the geometric accuracy. This paper concentrates on the on-orbit radiometric performance of the OLI, excepting the radiometric calibration performance. Topics discussed in this paper include: signal-to-noise ratios that are an order of magnitude higher than previous Landsat missions; radiometric uniformity that shows little residual banding and striping, and continues to improve; a dynamic range that limits saturation to extremely high radiance levels; extremely stable detectors; slight nonlinearity that is corrected in ground processing; detectors that are stable and 100% operable; and few image artifacts.

  11. Radiometric trace analysis of cobalt with diethyldithiocarbamate-35S, or 203Hg

    NARCIS (Netherlands)

    Erkelens, P.C. van

    1962-01-01

    Two radiometric methods for the determination of submugram amounts of cobalt are described. (A) Cobalt is extracted from an ammoniacal solution with a zinc-diethyldithiocarbamate-35S solution in chloroform. Excess reagent and interfering metals are removed with mercury(II) and cyanide. The 35S in

  12. Application of radioisotopes Au -198 to radiometrical field investigation of spraying machine

    Energy Technology Data Exchange (ETDEWEB)

    Goraczko, W.; Kocorowska, E. [Technical Univeristy, Poznan (Poland). Radio and Photo-Chemistry Department

    1997-10-01

    The poster shows application of radioisotope {sup 198}Au to radiometrical field testing of spraying machine. In the research was tested the Polish suspensioned tractor OZS400 type spraying machine. The machine worked in two different variants: without and with the beam stabilisation (oscillatory stabilisation)

  13. Establishing metrological traceability for radiometric calibration of earth observation sensor in Malaysia

    Science.gov (United States)

    Ng, S. W.; Zulkifli, A.

    2016-10-01

    The space borne earth observation (EO) sensor provides a continuous large spatial coverage over the earth at relatively low cost (cost-effective) and can be practically accessible worldwide. The daily synoptic view offered by instrument in earth orbit is tremendously useful in various applications, particularly long term global monitoring that needs multi-disciplinary, multi-temporal and multi-sensor data. Due to the indirect measurement nature of the EO sensor, calibration and validation (cal/val) are essentially required to establish the linkage between the acquired raw data and the actual target of interest. Ultimately, EO sensor provider must strive to deliver “the right information, at the right time, to the right people”. This paper is authored with the main aim to report the process of establishing metrological traceability for radiometric calibration of EO sensor at Optical Calibration Laboratory (OCL), National Space Agency of Malaysia (ANGKASA). The paper is structured into six sections. The first section introduces the context of EO and background of radiometric calibration. The next section discusses the requirements for metrological traceability in radiometric calibration while the following third section outlines ANGKASA efforts in setting up the metrological traceability laboratory in radiometric calibration. Meanwhile, the uncertainty estimation results is reported in the fourth section and the fifth section explains some of the continuous efforts made in order to improve the current metrological traceability set up. Lastly, the summary of this paper is provided in the last section.

  14. ANALYZING SPECTRAL CHARACTERISTICS OF SHADOW AREA FROM ADS-40 HIGH RADIOMETRIC RESOLUTION AERIAL IMAGES

    Directory of Open Access Journals (Sweden)

    Y.-T. Hsieh

    2016-06-01

    Full Text Available The shadows in optical remote sensing images are regarded as image nuisances in numerous applications. The classification and interpretation of shadow area in a remote sensing image are a challenge, because of the reduction or total loss of spectral information in those areas. In recent years, airborne multispectral aerial image devices have been developed 12-bit or higher radiometric resolution data, including Leica ADS-40, Intergraph DMC. The increased radiometric resolution of digital imagery provides more radiometric details of potential use in classification or interpretation of land cover of shadow areas. Therefore, the objectives of this study are to analyze the spectral properties of the land cover in the shadow areas by ADS-40 high radiometric resolution aerial images, and to investigate the spectral and vegetation index differences between the various shadow and non-shadow land covers. According to research findings of spectral analysis of ADS-40 image: (i The DN values in shadow area are much lower than in nonshadow area; (ii DN values received from shadowed areas that will also be affected by different land cover, and it shows the possibility of land cover property retrieval as in nonshadow area; (iii The DN values received from shadowed regions decrease in the visible band from short to long wavelengths due to scattering; (iv The shadow area NIR of vegetation category also shows a strong reflection; (v Generally, vegetation indexes (NDVI still have utility to classify the vegetation and non-vegetation in shadow area. The spectral data of high radiometric resolution images (ADS-40 is potential for the extract land cover information of shadow areas.

  15. Analyzing Spectral Characteristics of Shadow Area from ADS-40 High Radiometric Resolution Aerial Images

    Science.gov (United States)

    Hsieh, Yi-Ta; Wu, Shou-Tsung; Chen, Chaur-Tzuhn; Chen, Jan-Chang

    2016-06-01

    The shadows in optical remote sensing images are regarded as image nuisances in numerous applications. The classification and interpretation of shadow area in a remote sensing image are a challenge, because of the reduction or total loss of spectral information in those areas. In recent years, airborne multispectral aerial image devices have been developed 12-bit or higher radiometric resolution data, including Leica ADS-40, Intergraph DMC. The increased radiometric resolution of digital imagery provides more radiometric details of potential use in classification or interpretation of land cover of shadow areas. Therefore, the objectives of this study are to analyze the spectral properties of the land cover in the shadow areas by ADS-40 high radiometric resolution aerial images, and to investigate the spectral and vegetation index differences between the various shadow and non-shadow land covers. According to research findings of spectral analysis of ADS-40 image: (i) The DN values in shadow area are much lower than in nonshadow area; (ii) DN values received from shadowed areas that will also be affected by different land cover, and it shows the possibility of land cover property retrieval as in nonshadow area; (iii) The DN values received from shadowed regions decrease in the visible band from short to long wavelengths due to scattering; (iv) The shadow area NIR of vegetation category also shows a strong reflection; (v) Generally, vegetation indexes (NDVI) still have utility to classify the vegetation and non-vegetation in shadow area. The spectral data of high radiometric resolution images (ADS-40) is potential for the extract land cover information of shadow areas.

  16. A versatile noninvasive method for adsorber quantification in batch and column chromatography based on the ionic capacity.

    Science.gov (United States)

    Huuk, Thiemo C; Briskot, Till; Hahn, Tobias; Hubbuch, Jürgen

    2016-05-01

    Within the Quality by Design (QbD) framework proposed by the International Conference on Harmonisation (ICH), high-throughput process development (HTPD) and mechanistic modeling are of outstanding importance for future biopharmaceutical chromatography process development. In order to compare the data derived from different column scales or batch chromatographies, the amount of adsorber has to be quantified with the same noninvasive method. Similarly, an important requirement for the implementation of mechanistic modeling is the reliable determination of column characteristics such as the ionic capacity Λ for ion-exchange chromatography with the same method at all scales and formats. We developed a method to determine the ionic capacity in column and batch chromatography, based on the adsorption/desorption of the natural, uv-detectable amino acid histidine. In column chromatography, this method produces results comparable to those of classical acid-base titration. In contrast to acid-base titration, this method can be adapted to robotic batch chromatographic experiments. We are able to convert the adsorber volumes in batch chromatography to the equivalent volume of a compressed column. In a case study, we demonstrate that this method increases the quality of SMA parameters fitted to batch adsorption isotherms, and the capability to predict column breakthrough experiments. © 2016 American Institute of Chemical Engineers Biotechnol. Prog., 32:666-677, 2016.

  17. Generic chromatography-based purification strategies accelerate the development of downstream processes for biopharmaceutical proteins produced in plants.

    Science.gov (United States)

    Buyel, Johannes F; Fischer, Rainer

    2014-04-01

    Plants offer a valuable alternative to cultured mammalian cells for the production of recombinant biopharmaceutical proteins. However, the target protein typically represents only a minor fraction of the total protein in the initial plant extract, which means that the development of product-specific chromatography-based purification strategies is often laborious and expensive. To address this challenge, we designed a generic downstream process that is suitable for the purification of recombinant proteins with diverse properties from plant production platforms. This was achieved by focusing on the binding behavior of tobacco host cell proteins (HCPs) to a broad set of chromatography resins under different pH and conductivity conditions. Strong cation exchanger and salt-tolerant anion exchanger resins exhibited the best resolution of tobacco HCPs among the 13 tested resins, and their selectivity was easy to manipulate through the adjustment of pH and conductivity. The advantages, such as direct capture of a target protein from leaf extract, and limitations, such as low binding capacity, of various chromatography ligands and resins are discussed. We also address the most useful applications of the chromatography ligands, namely recovery of proteins with a certain pI, in a downstream process that aims to purify diverse plant-derived biopharmaceutical proteins. Based on these results, we describe generic purification schemes that are suitable for acidic, neutral, and basic target proteins, as a first step toward the development of industrial platform processes.

  18. Automated geographic registration and radiometric correction for UAV-based mosaics

    Science.gov (United States)

    Thomasson, J. Alex; Shi, Yeyin; Sima, Chao; Yang, Chenghai; Cope, Dale A.

    2017-05-01

    Texas A and M University has been operating a large-scale, UAV-based, agricultural remote-sensing research project since 2015. To use UAV-based images in agricultural production, many high-resolution images must be mosaicked together to create an image of an agricultural field. Two key difficulties to science-based utilization of such mosaics are geographic registration and radiometric calibration. In our current research project, image files are taken to the computer laboratory after the flight, and semi-manual pre-processing is implemented on the raw image data, including ortho-mosaicking and radiometric calibration. Ground control points (GCPs) are critical for high-quality geographic registration of images during mosaicking. Applications requiring accurate reflectance data also require radiometric-calibration references so that reflectance values of image objects can be calculated. We have developed a method for automated geographic registration and radiometric correction with targets that are installed semi-permanently at distributed locations around fields. The targets are a combination of black (≍5% reflectance), dark gray (≍20% reflectance), and light gray (≍40% reflectance) sections that provide for a transformation of pixel-value to reflectance in the dynamic range of crop fields. The exact spectral reflectance of each target is known, having been measured with a spectrophotometer. At the time of installation, each target is measured for position with a real-time kinematic GPS receiver to give its precise latitude and longitude. Automated location of the reference targets in the images is required for precise, automated, geographic registration; and automated calculation of the digital-number to reflectance transformation is required for automated radiometric calibration. To validate the system for radiometric calibration, a calibrated UAV-based image mosaic of a field was compared to a calibrated single image from a manned aircraft. Reflectance

  19. Mississippi exploration field trials using microbial, radiometrics, free soil gas, and other techniques

    Energy Technology Data Exchange (ETDEWEB)

    Moody, J.S.; Brown, L.R.; Thieling, S.C.

    1995-12-31

    The Mississippi Office of Geology has conducted field trials using the surface exploration techniques of geomicrobial, radiometrics, and free soil gas. The objective of these trials is to determine if Mississippi oil and gas fields have surface hydrocarbon expression resulting from vertical microseepage migration. Six fields have been surveyed ranging in depth from 3,330 ft to 18,500 ft. The fields differ in trapping styles and hydrocarbon type. The results so far indicate that these fields do have a surface expression and that geomicrobial analysis as well as radiometrics and free soil gas can detect hydrocarbon microseepage from pressurized reservoirs. All three exploration techniques located the reservoirs independent of depth, hydrocarbon type, or trapping style.

  20. An information theory characterization of radar images and a new definition for radiometric resolution

    Science.gov (United States)

    Frost, V. S.; Shanmugan, K. S.; Holtzman, J. C.

    1982-01-01

    The noise properties of the radar image formation process are used in the present modeling of a communication channel in which the desired target properties are the information transmitted, and the final image represents the received signal. The average information rate over this communication channel is calculated together with appropriate bounds and approximations, and is found to be small on a per-sample basis. As a result, many samples must be averaged to allow for the discrimination, or classification, of several levels of target reflectivity. These information rate properties are consistent with known results concerning target detection and image quality in speckle, and the rate is applicable to the definition of radar image radiometric resolution. Radiometric resolution is functionally related to the degree of noncoherent averaging performed by the sensor.

  1. Determination of Cloud Ice Water Content and Geometrical Thickness Using Microwave and Infrared Radiometric Measurements.

    Science.gov (United States)

    Wu, Man-Li C.

    1987-08-01

    Cloud ice water content and cloud geometrical thickness have been determined using a combination of near-infrared, thermal infrared and thermal microwave radiometric measurements. The radiometric measurements are from a Multispectral Cloud Radiometer, which has seven channels ranging from visible to thermal infrared, and an Advanced Microwave Moisture Sounder, which has four channels ranging from 90 to 183 GHz. Studies indicate that the microwave brightness temperatures depend not only on the amount of ice water content but also on the vertical distribution of ice water content. Studies also show that the low brightness temperature at 92 GHz for large ice water content is due to cloud reflection which reflects most of the irradiance incident at the cloud base downward. Therefore the 92 GHz channel detects a low brightness temperature at the cloud top.

  2. Contact sensitivity in mice evaluated by means of ear swelling and a radiometric test

    Energy Technology Data Exchange (ETDEWEB)

    Baeck, O.; Larsen, A.

    1982-04-01

    Contact sensitivity to picryl chloride was investigated by means of the ear swelling test and a radiometric test in order to establish optimal experimental conditions for these assays. Contact sensitivity was demonstrated as soon as 2 days after sensitization, with a maximum reaction 3-4 days after sensitization, when a 48 hr test reaction was registered. The test reaction was followed for 72 hr and maximum was arrived at after 24 hr and 48 hr for the ear swelling test and the radiometric test, respectively. Optimal sensitization was reached with a 7% solution of picryl chloride and a maximum test reaction was found with 0.75-1.0% picryl chloride. It is concluded that both assays measure contact sensitivity in quantitative terms and a future replacement of the guinea pig maximization test is discussed.

  3. HJ-1A HSI on-orbit radiometric calibration and validation research

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    The calibration experiment data at Dunhuang radiometric calibration site in October, 2008 were used to achieve the on-orbit radiometric calibration for HJ-1A hyper spectral imager (HSI). Two other field experiments data were used to validate the Dunhuang calibration results. One field experiment took place in Inner-Mongolia, China in September, 2008, and the other field experiment took place in Lake Frome, Australia in February, 2009. Finally, the ‘confidence interval of calibration error’ concept was put forward for quantitatively computing the calibration coefficient error confidence interval. The results showed that the Dunhuang calibration results in 2008 had high reliability. The confidence intervals of calibration error for all HSI channels were between 2% to 12%, which could satisfy the requirement of the HSI quantitative applications.

  4. Extreme Ultraviolet Variability Experiment (EVE) Multiple EUV Grating Spectrographs (MEGS): Radiometric Calibrations and Results

    Science.gov (United States)

    Hock, R. A.; Woods, T. N.; Crotser, D.; Eparvier, F. G.; Woodraska, D. L.; Chamberlin, P. C.; Woods, E. C.

    2010-01-01

    The NASA Solar Dynamics Observatory (SDO), scheduled for launch in early 2010, incorporates a suite of instruments including the Extreme Ultraviolet Variability Experiment (EVE). EVE has multiple instruments including the Multiple Extreme ultraviolet Grating Spectrographs (MEGS) A, B, and P instruments, the Solar Aspect Monitor (SAM), and the Extreme ultraviolet SpectroPhotometer (ESP). The radiometric calibration of EVE, necessary to convert the instrument counts to physical units, was performed at the National Institute of Standards and Technology (NIST) Synchrotron Ultraviolet Radiation Facility (SURF III) located in Gaithersburg, Maryland. This paper presents the results and derived accuracy of this radiometric calibration for the MEGS A, B, P, and SAM instruments, while the calibration of the ESP instrument is addressed by Didkovsky et al. . In addition, solar measurements that were taken on 14 April 2008, during the NASA 36.240 sounding-rocket flight, are shown for the prototype EVE instruments.

  5. Determination of in vitro susceptibility of Mycobacterium tuberculosis to cephalosporins by radiometric and conventional methods

    Energy Technology Data Exchange (ETDEWEB)

    Heifets, L.B.; Iseman, M.D.; Cook, J.L.; Lindholm-Levy, P.J.; Drupa, I.

    1985-01-01

    Among eight cephalosporins and cephamycins tested in preliminary in vitro screening against Mycobacterium tuberculosis, the most promising for further study was found to be ceforanide, followed by ceftizoxime, cephapirin, and cefotaxime. Moxalactam, cefoxitin, cefamandole, and cephalothin were found to be not active enough against M. tuberculosis to be considered for further in vitro studies. The antibacterial activity of various ceforanide concentrations was investigated by three methods: (i) the dynamics of radiometric readings (growth index) in 7H12 broth; (ii) the number of CFU in the same medium; and (iii) the proportion method on 7H11 agar plates. There was a good correlation among the results obtained with these methods. The MIC for most strains ranged from 6.0 to 25.0 micrograms/ml. The BACTEC radiometric method is a reliable, rapid, and convenient method for preliminary screening and determination of the level of antibacterial activity of drugs not commonly used against M. tuberculosis.

  6. Improved thermal-vacuum compatible flat plate radiometric source for system-level testing of remote optical sensors

    Science.gov (United States)

    Schwarz, Mark A.; Kent, Craig J.; Bousquet, Robert; Brown, Steven W.

    2016-09-01

    In this work, we describe an improved thermal-vacuum compatible flat plate radiometric source which has been developed and utilized for the characterization and calibration of remote optical sensors. This source is unique in that it can be used in situ, in both ambient and thermal-vacuum environments, allowing it to follow the sensor throughout its testing cycle. The performance of the original flat plate radiometric source was presented at the 2009 SPIE1. Following the original efforts, design upgrades were incorporated into the source to improve both radiometric throughput and uniformity. The pre-thermal-vacuum (pre-TVAC) testing results of a spacecraft-level optical sensor with the improved flat plate illumination source, both in ambient and vacuum environments, are presented. We also briefly discuss potential FPI configuration changes in order to improve its radiometric performance. Keywords: Calibration, radiometry, remote sensing, source.

  7. Development of absolute radiometric response functions for HyPlant & G-LiHT using SIRCUS Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The goal of this project is to provide absolute radiometric and cross-calibrated spectral characterizations for G-LiHT and HyPlant.  The objectives are: (i) to...

  8. A new relative radiometric consistency processing method for change detection based on wavelet transform and a low-pass filter

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    The research purpose of this paper is to show the limitations of the existing radiometric normalization approaches and their disadvantages in change detection of artificial objects by comparing the existing approaches,on the basis of which a preprocessing approach to radiometric consistency,based on wavelet transform and a spatial low-pass filter,has been devised.This approach first separates the high frequency information and low frequency information by wavelet transform.Then,the processing of relative radiometric consistency based on a low-pass filter is conducted on the low frequency parts.After processing,an inverse wavelet transform is conducted to obtain the results image.The experimental results show that this approach can substantially reduce the influence on change detection of linear or nonlinear radiometric differences in multi-temporal images.

  9. Improving Ocean Color Data Products using a Purely Empirical Approach: Reducing the Requirement for Radiometric Calibration Accuracy

    Science.gov (United States)

    Gregg, Watson

    2008-01-01

    Radiometric calibration is the foundation upon which ocean color remote sensing is built. Quality derived geophysical products, such as chlorophyll, are assumed to be critically dependent upon the quality of the radiometric calibration. Unfortunately, the goals of radiometric calibration are not typically met in global and large-scale regional analyses, and are especially deficient in coastal regions. The consequences of the uncertainty in calibration are very large in terms of global and regional ocean chlorophyll estimates. In fact, stability in global chlorophyll requires calibration uncertainty much greater than the goals, and outside of modern capabilities. Using a purely empirical approach, we show that stable and consistent global chlorophyll values can be achieved over very wide ranges of uncertainty. Furthermore, the approach yields statistically improved comparisons with in situ data, suggesting improved quality. The results suggest that accuracy requirements for radiometric calibration cab be reduced if alternative empirical approaches are used.

  10. High-speed radiometric imaging with a gated, intensified, digitally controlled camera

    Science.gov (United States)

    Ross, Charles C.; Sturz, Richard A.

    1997-05-01

    The development of an advanced instrument for real-time radiometric imaging of high-speed events is described. The Intensified Digitally-Controlled Gated (IDG) camera is a microprocessor-controlled instrument based on an intensified CCD that is specifically designed to provide radiometric optical data. The IDG supports a variety of camera- synchronous and camera-asynchronous imaging tasks in both passive imaging and active laser range-gated applications. It features both automatic and manual modes of operation, digital precision and repeatability, and ease of use. The IDG produces radiometric imagery by digitally controlling the instrument's optical gain and exposure duration, and by encoding and annotating the parameters necessary for radiometric analysis onto the resultant video signal. Additional inputs, such as date, time, GPS, IRIG-B timing, and other data can also be encoded and annotated. The IDG optical sensitivity can be readily calibrated, with calibration data tables stored in the camera's nonvolatile flash memory. The microprocessor then uses this data to provide a linear, calibrated output. The IDG possesses both synchronous and asynchronous imaging modes in order to allow internal or external control of exposure, timing, and direct interface to external equipment such as event triggers and frame grabbers. Support for laser range-gating is implemented by providing precise asynchronous CCD operation and nanosecond resolution of the intensifier photocathode gate duration and timing. Innovative methods used to control the CCD for asynchronous image capture, as well as other sensor and system considerations relevant to high-speed imaging are discussed in this paper.

  11. A procedure for radiometric recalibration of Landsat 5 TM reflective-band data

    Science.gov (United States)

    Chander, G.; Haque, M.O.; Micijevic, E.; Barsi, J.A.

    2010-01-01

    From the Landsat program's inception in 1972 to the present, the Earth science user community has been benefiting from a historical record of remotely sensed data. The multispectral data from the Landsat 5 (L5) Thematic Mapper (TM) sensor provide the backbone for this extensive archive. Historically, the radiometric calibration procedure for the L5 TM imagery used the detectors' response to the internal calibrator (IC) on a scene-by-scene basis to determine the gain and offset for each detector. The IC system degraded with time, causing radiometric calibration errors up to 20%. In May 2003, the L5 TM data processed and distributed by the U.S. Geological Survey (USGS) Earth Resources Observation and Science Center through the National Landsat Archive Production System (NLAPS) were updated to use a lifetime lookup-table (LUT) gain model to radiometrically calibrate TM data instead of using scene-specific IC gains. Further modification of the gain model was performed in 2007. The L5 TM data processed using IC prior to the calibration update do not benefit from the recent calibration revisions. A procedure has been developed to give users the ability to recalibrate their existing level-1 products. The best recalibration results are obtained if the work-order report that was included in the original standard data product delivery is available. However, if users do not have the original work-order report, the IC trends can be used for recalibration. The IC trends were generated using the radiometric gain trends recorded in the NLAPS database. This paper provides the details of the recalibration procedure for the following: 1) data processed using IC where users have the work-order file; 2) data processed using IC where users do not have the work-order file; 3) data processed using prelaunch calibration parameters; and 4) data processed using the previous version of the LUT (e.g., LUT03) that was released before April 2, 2007.

  12. Reduction of Striping Noise in Overlapping LIDAR Intensity Data by Radiometric Normalization

    Science.gov (United States)

    Yan, Wai Yeung; Shaker, Ahmed

    2016-06-01

    To serve seamless mapping, airborne LiDAR data are usually collected with multiple parallel strips with one or two cross strip(s). Nevertheless, the overlapping regions of LiDAR data strips are usually found with unbalanced intensity values, resulting in the appearance of stripping noise. Despite that physical intensity correction methods are recently proposed, some of the system and environmental parameters are assumed as constant or not disclosed, leading to such an intensity discrepancy. This paper presents a new normalization technique to adjust the radiometric misalignment found in the overlapping LiDAR data strips. The normalization technique is built upon a second-order polynomial function fitted on the joint histogram plot, which is generated with a set of pairwise closest data points identified within the overlapping region. The method was tested on Teledyne Optech's Gemini dataset (at 1064 nm wavelength), where the LiDAR intensity data were first radiometrically corrected based on the radar (range) equation. Five land cover features were selected to evaluate the coefficient of variation (cv) of the intensity values before and after implementing the proposed method. Reduction of cv was found by 19% to 59% in the Gemini dataset, where the striping noise was significantly reduced in the radiometrically corrected and normalized intensity data. The Gemini dataset was also used to conduct land cover classification, and the overall accuracy yielded a notable improvement of 9% to 18%. As a result, LiDAR intensity data should be pre-processed with radiometric correction and normalization prior to any data manipulation.

  13. Impact of the cameras radiometric resolution on the accuracy of determining spectral reflectance coefficients

    Science.gov (United States)

    Orych, A.; Walczykowski, P.; Jenerowicz, A.; Zdunek, Z.

    2014-11-01

    Nowadays remote sensing plays a very important role in many different study fields, i.e. environmental studies, hydrology, mineralogy, ecosystem studies, etc. One of the key areas of remote sensing applications is water quality monitoring. Understanding and monitoring of the water quality parameters and detecting different water contaminants is an important issue in water management and protection of whole environment and especially the water ecosystem. There are many remote sensing methods to monitor water quality and detect water pollutants. One of the most widely used method for substance detection with remote sensing techniques is based on usage of spectral reflectance coefficients. They are usually acquired using discrete methods such as spectrometric measurements. These however can be very time consuming, therefore image-based methods are used more and more often. In order to work out the proper methodology of obtaining spectral reflectance coefficients from hyperspectral and multispectral images, it is necessary to verify the impact of cameras radiometric resolution on the accuracy of determination of them. This paper presents laboratory experiments that were conducted using two monochromatic XEVA video sensors (400-1700 nm spectral data registration) with two different radiometric resolutions (12 and 14 bits). In view of determining spectral characteristics from images, the research team used set of interferometric filters. All data collected with multispectral digital video cameras were compared with spectral reflectance coefficients obtained with spectroradiometer. The objective of this research is to find the impact of cameras radiometric resolution on reflectance values in chosen wavelength. The main topic of this study is the analysis of accuracy of spectral coefficients from sensors with different radiometric resolution. By comparing values collected from images acquired with XEVA sensors and with the curves obtained with spectroradiometer it

  14. A new automatic system for angular measurement and calibration in radiometric instruments.

    Science.gov (United States)

    Marquez, Jose Manuel Andujar; Bohórquez, Miguel Ángel Martínez; Garcia, Jonathan Medina; Nieto, Francisco Jose Aguilar

    2010-01-01

    This paper puts forward the design, construction and testing of a new automatic system for angular-response measurement and calibration in radiometric instruments. Its main characteristics include precision, speed, resolution, noise immunity, easy programming and operation. The developed system calculates the cosine error of the radiometer under test by means of a virtual instrument, from the measures it takes and through a mathematical procedure, thus allowing correcting the radiometer with the aim of preventing cosine error in its measurements.

  15. A New Automatic System for Angular Measurement and Calibration in Radiometric Instruments

    Directory of Open Access Journals (Sweden)

    Jose Manuel Andujar Marquez

    2010-04-01

    Full Text Available This paper puts forward the design, construction and testing of a new automatic system for angular-response measurement and calibration in radiometric instruments. Its main characteristics include precision, speed, resolution, noise immunity, easy programming and operation. The developed system calculates the cosine error of the radiometer under test by means of a virtual instrument, from the measures it takes and through a mathematical procedure, thus allowing correcting the radiometer with the aim of preventing cosine error in its measurements.

  16. Prime candidate earth targets for the post-launch radiometric calibration of space-based optical imaging instruments

    Science.gov (United States)

    Teillet, P.M.; Barsi, J.A.; Chander, G.; Thome, K.J.

    2007-01-01

    This paper provides a comprehensive list of prime candidate terrestrial targets for consideration as benchmark sites for the post-launch radiometric calibration of space-based instruments. The key characteristics of suitable sites are outlined primarily with respect to selection criteria, spatial uniformity, and temporal stability. The establishment and utilization of such benchmark sites is considered an important element of the radiometric traceability of satellite image data products for use in the accurate monitoring of environmental change.

  17. Radiometric Calibration of a Dual-Wavelength, Full-Waveform Terrestrial Lidar

    Science.gov (United States)

    Li, Zhan; Jupp, David L. B.; Strahler, Alan H.; Schaaf, Crystal B.; Howe, Glenn; Hewawasam, Kuravi; Douglas, Ewan S.; Chakrabarti, Supriya; Cook, Timothy A.; Paynter, Ian; Saenz, Edward J.; Schaefer, Michael

    2016-01-01

    Radiometric calibration of the Dual-Wavelength Echidna® Lidar (DWEL), a full-waveform terrestrial laser scanner with two simultaneously-pulsing infrared lasers at 1064 nm and 1548 nm, provides accurate dual-wavelength apparent reflectance (ρapp), a physically-defined value that is related to the radiative and structural characteristics of scanned targets and independent of range and instrument optics and electronics. The errors of ρapp are 8.1% for 1064 nm and 6.4% for 1548 nm. A sensitivity analysis shows that ρapp error is dominated by range errors at near ranges, but by lidar intensity errors at far ranges. Our semi-empirical model for radiometric calibration combines a generalized logistic function to explicitly model telescopic effects due to defocusing of return signals at near range with a negative exponential function to model the fall-off of return intensity with range. Accurate values of ρapp from the radiometric calibration improve the quantification of vegetation structure, facilitate the comparison and coupling of lidar datasets from different instruments, campaigns or wavelengths and advance the utilization of bi- and multi-spectral information added to 3D scans by novel spectral lidars. PMID:26950126

  18. Radiometric resolution enhancement by lossy compression as compared to truncation followed by lossless compression

    Science.gov (United States)

    Tilton, James C.; Manohar, Mareboyana

    1994-01-01

    Recent advances in imaging technology make it possible to obtain imagery data of the Earth at high spatial, spectral and radiometric resolutions from Earth orbiting satellites. The rate at which the data is collected from these satellites can far exceed the channel capacity of the data downlink. Reducing the data rate to within the channel capacity can often require painful trade-offs in which certain scientific returns are sacrificed for the sake of others. In this paper we model the radiometric version of this form of lossy compression by dropping a specified number of least significant bits from each data pixel and compressing the remaining bits using an appropriate lossless compression technique. We call this approach 'truncation followed by lossless compression' or TLLC. We compare the TLLC approach with applying a lossy compression technique to the data for reducing the data rate to the channel capacity, and demonstrate that each of three different lossy compression techniques (JPEG/DCT, VQ and Model-Based VQ) give a better effective radiometric resolution than TLLC for a given channel rate.

  19. Calibrating Late Quaternary terrestrial climate signals: radiometrically dated pollen evidence from the southern Sierra Nevada, USA

    Science.gov (United States)

    Litwin, Ronald J.; Smoot, Joseph P.; Durika, Nancy J.; Smith, George I.

    1999-01-01

    We constructed a radiometrically calibrated proxy record of Late Pleistocene and Holocene climate change exceeding 230,000 yr duration, using pollen profiles from two cores taken through age-equivalent dry lakes - one core having greater age control (via 230Th alpha mass-spectrometry) and the other having greater stratigraphic completeness. The better dated of these two serial pollen records (Searles Lake) served as a reference section for improving the effective radiometric age control in a nearby and more complete pollen record (Owens Lake) because they: (1) are situated ~90 km apart in the same drainage system (on, and immediately leeward of, the eastern flank of the Sierra Nevada), and (2) preserved strikingly similar pollen profiles and concordant sequences of sedimentological changes. Pollen assemblages from both lakes are well preserved and diverse, and document serial changes in Late Pleistocene and Holocene plant zone distribution and composition in the westernmost Great Basin; they consist of taxa now inhabiting montane forest, woodland, steppe, and desert-scrub environments. The studied core intervals are interpreted here to be the terrestrial equivalent of marine δ18O stages 1 through 9; these pollen profiles now appear to be among the best radiometrically dated Late Pleistocene records of terrestrial climate change known.

  20. Radiometric 81Kr dating identifies 120,000-year-old ice at Taylor Glacier, Antarctica.

    Science.gov (United States)

    Buizert, Christo; Baggenstos, Daniel; Jiang, Wei; Purtschert, Roland; Petrenko, Vasilii V; Lu, Zheng-Tian; Müller, Peter; Kuhl, Tanner; Lee, James; Severinghaus, Jeffrey P; Brook, Edward J

    2014-05-13

    We present successful (81)Kr-Kr radiometric dating of ancient polar ice. Krypton was extracted from the air bubbles in four ∼350-kg polar ice samples from Taylor Glacier in the McMurdo Dry Valleys, Antarctica, and dated using Atom Trap Trace Analysis (ATTA). The (81)Kr radiometric ages agree with independent age estimates obtained from stratigraphic dating techniques with a mean absolute age offset of 6 ± 2.5 ka. Our experimental methods and sampling strategy are validated by (i) (85)Kr and (39)Ar analyses that show the samples to be free of modern air contamination and (ii) air content measurements that show the ice did not experience gas loss. We estimate the error in the (81)Kr ages due to past geomagnetic variability to be below 3 ka. We show that ice from the previous interglacial period (Marine Isotope Stage 5e, 130-115 ka before present) can be found in abundance near the surface of Taylor Glacier. Our study paves the way for reliable radiometric dating of ancient ice in blue ice areas and margin sites where large samples are available, greatly enhancing their scientific value as archives of old ice and meteorites. At present, ATTA (81)Kr analysis requires a 40-80-kg ice sample; as sample requirements continue to decrease, (81)Kr dating of ice cores is a future possibility.

  1. Radiometric 81Kr dating identifies 120,000 year old ice at Taylor Glacier, Antarctica

    CERN Document Server

    Buizert, Christo; Jiang, Wei; Purtschert, Roland; Petrenko, Vasilii V; Lu, Zheng-Tian; Mueller, Peter; Kuhl, Tanner; Lee, James; Severinghaus, Jeffrey P; Brook, Edward J

    2014-01-01

    We present the first successful 81Kr-Kr radiometric dating of ancient polar ice. Krypton was extracted from the air bubbles in four ~350 kg polar ice samples from Taylor Glacier in the McMurdo Dry Valleys, Antarctica, and dated using Atom Trap Trace Analysis (ATTA). The 81Kr radiometric ages agree with independent age estimates obtained from stratigraphic dating techniques with a mean absolute age offset of 6 +/- 2.5 ka. Our experimental methods and sampling strategy are validated by 1) 85Kr and 39Ar analyses that show the samples to be free of modern air contamination, and 2) air content measurements that show the ice did not experience gas loss. We estimate the error in the 81Kr ages due to past geomagnetic variability to be below 3 ka. We show that ice from the previous interglacial period (MIS 5e, 130-115 ka before present) can be found in abundance near the surface of Taylor Glacier. Our study paves the way for reliable radiometric dating of ancient ice in blue ice areas and margin sites where large samp...

  2. Radiometric Calibration of a Dual-Wavelength, Full-Waveform Terrestrial Lidar.

    Science.gov (United States)

    Li, Zhan; Jupp, David L B; Strahler, Alan H; Schaaf, Crystal B; Howe, Glenn; Hewawasam, Kuravi; Douglas, Ewan S; Chakrabarti, Supriya; Cook, Timothy A; Paynter, Ian; Saenz, Edward J; Schaefer, Michael

    2016-03-02

    Radiometric calibration of the Dual-Wavelength Echidna(®) Lidar (DWEL), a full-waveform terrestrial laser scanner with two simultaneously-pulsing infrared lasers at 1064 nm and 1548 nm, provides accurate dual-wavelength apparent reflectance (ρ(app)), a physically-defined value that is related to the radiative and structural characteristics of scanned targets and independent of range and instrument optics and electronics. The errors of ρ(app) are 8.1% for 1064 nm and 6.4% for 1548 nm. A sensitivity analysis shows that ρ(app) error is dominated by range errors at near ranges, but by lidar intensity errors at far ranges. Our semi-empirical model for radiometric calibration combines a generalized logistic function to explicitly model telescopic effects due to defocusing of return signals at near range with a negative exponential function to model the fall-off of return intensity with range. Accurate values of ρ(app) from the radiometric calibration improve the quantification of vegetation structure, facilitate the comparison and coupling of lidar datasets from different instruments, campaigns or wavelengths and advance the utilization of bi- and multi-spectral information added to 3D scans by novel spectral lidars.

  3. Application of an online ion-chromatography-based instrument for gradient flux measurements of speciated nitrogen and sulfur

    Science.gov (United States)

    Rumsey, Ian C.; Walker, John T.

    2016-06-01

    The dry component of total nitrogen and sulfur atmospheric deposition remains uncertain. The lack of measurements of sufficient chemical speciation and temporal extent make it difficult to develop accurate mass budgets and sufficient process level detail is not available to improve current air-surface exchange models. Over the past decade, significant advances have been made in the development of continuous air sampling measurement techniques, resulting with instruments of sufficient sensitivity and temporal resolution to directly quantify air-surface exchange of nitrogen and sulfur compounds. However, their applicability is generally restricted to only one or a few of the compounds within the deposition budget. Here, the performance of the Monitor for AeRosols and GAses in ambient air (MARGA 2S), a commercially available online ion-chromatography-based analyzer is characterized for the first time as applied for air-surface exchange measurements of HNO3, NH3, NH4+, NO3-, SO2 and SO42-. Analytical accuracy and precision are assessed under field conditions. Chemical concentrations gradient precision are determined at the same sampling site. Flux uncertainty measured by the aerodynamic gradient method is determined for a representative 3-week period in fall 2012 over a grass field. Analytical precision and chemical concentration gradient precision were found to compare favorably in comparison to previous studies. During the 3-week period, percentages of hourly chemical concentration gradients greater than the corresponding chemical concentration gradient detection limit were 86, 42, 82, 73, 74 and 69 % for NH3, NH4+, HNO3, NO3-, SO2 and SO42-, respectively. As expected, percentages were lowest for aerosol species, owing to their relatively low deposition velocities and correspondingly smaller gradients relative to gas phase species. Relative hourly median flux uncertainties were 31, 121, 42, 43, 67 and 56 % for NH3, NH4+, HNO3, NO3-, SO2 and SO42-, respectively. Flux

  4. [VMTBB-Based Spectral Radiometric Calibration of NIR Fiber Coupled Spectrometer].

    Science.gov (United States)

    Zheng, Feng; Liu, Li-ying; Liu, Xiao-xi; Li, Ye; Shi, Xiao-guang; Zhang, Guo-yu; Huan, Ke-wei

    2015-09-01

    The medium temperature black body (MTBB) is conventional high precision equipment used as spectral radiometric scale in infrared spectral region. However, in near-infrared (NIR) spectral region, there are few papers about spectral radiometric calibration by using MTBB, that is because NIR spectral region is the borderland of its effective spectral region. The main research of this paper is spectral radiometric calibration method by using MTBB in NIR spectral region. Accordingly, this paper is devoted mostly to a discussion of how the calibration precision could be affected by selecting different structural parameters of calibration model. The purpose of this paper is to present the results of research and provide technical reference for improving the traceability in NIR spectral radiometric calibration. In this paper, a NIR fiber coupled spectrometer, whose wavelength range covers from 950 to 1700 nm, has been calibrated by a MTBB with adjustable temperature range from 50 to 1050 °C. Concentrating on calibration process, two key points have been discussed. For one thing, the geometric factors of radiation transfer model of the calibration systems have been compared between traditional structure and fiber direct-coupled structure. Because the fiber direct-coupled model is simple and effective, it has been selected instead of traditional model based on the radiation transfer between two coaxial discs. So, it is an advantaged radiation transfer model for radiometric calibration of fiber coupled spectrometer. For another thing, the relation between calibration accuracy and structural parameters of calibration model has been analyzed intensively. The root cause is scale feature of attribute of calibration data itself, which is the nonlinear structure in scales of spectral data. So, the high precision calibration needs nonlinear calibration model, and the uniform sampling for scale feature is also very important. Selecting sample is an inevitable problem when the

  5. MSFIA-LOV system for (226)Ra isolation and pre-concentration from water samples previous radiometric detection.

    Science.gov (United States)

    Rodríguez, Rogelio; Borràs, Antoni; Leal, Luz; Cerdà, Víctor; Ferrer, Laura

    2016-03-10

    An automatic system based on multisyringe flow injection analysis (MSFIA) and lab-on-valve (LOV) flow techniques for separation and pre-concentration of (226)Ra from drinking and natural water samples has been developed. The analytical protocol combines two different procedures: the Ra adsorption on MnO2 and the BaSO4 co-precipitation, achieving more selectivity especially in water samples with low radium levels. Radium is adsorbed on MnO2 deposited on macroporous of bead cellulose. Then, it is eluted with hydroxylamine to transform insoluble MnO2 to soluble Mn(II) thus freeing Ra, which is then coprecipitated with BaSO4. The (226)Ra can be directly detected in off-line mode using a low background proportional counter (LBPC) or through a liquid scintillation counter (LSC), after performing an on-line coprecipitate dissolution. Thus, the versatility of the proposed system allows the selection of the radiometric detection technique depending on the detector availability or the required response efficiency (sample number vs. response time and limit of detection). The MSFIA-LOV system improves the precision (1.7% RSD), and the extraction frequency (up to 3 h(-1)). Besides, it has been satisfactorily applied to different types of water matrices (tap, mineral, well and sea water). The (226)Ra minimum detectable activities (LSC: 0.004 Bq L(-1); LBPC: 0.02 Bq L(-1)) attained by this system allow to reach the guidance values proposed by the relevant international agencies e.g. WHO, EPA and EC.

  6. A review of novel strategies of sample preparation for the determination of antibacterial residues in foodstuffs using liquid chromatography-based analytical methods

    Energy Technology Data Exchange (ETDEWEB)

    Marazuela, M.D., E-mail: marazuela@quim.ucm.es [Department of Analytical Chemistry, Faculty of Chemistry, Universidad Complutense de Madrid, E-28040 Madrid (Spain); Bogialli, S. [Department of Chemistry, University of Rome ' La Sapienza' , Piazza Aldo Moro, 5 00185 Rome (Italy)

    2009-07-10

    The determination of trace residues and contaminants in food has been of growing concern over the past few years. Residual antibacterials in food constitute a risk to human health, especially because they can contribute to the transmission of antibiotic-resistant pathogenic bacteria through the food chain. Therefore, to ensure food safety EU and USA regulatory agencies have established lists of forbidden or banned substances and tolerance levels for authorized veterinary drugs (e.g. antibacterials). In addition, the EU Commission Decision 2002/657/EC has set requirements about the performance of analytical methods for the determination of veterinary drug residues in food and feedstuffs. During the past years, the use of powerful mass spectrometric detectors in combination with innovative chromatographic technologies has solved many problems related to sensitivity and selectivity of this type of analysis. However sample preparation still remains as the bottleneck step, mainly in terms of analysis time and sources of error. This review covering research published between 2004 and 2008 intends to provide an update overview of the past five years, on recent trends in sample preparation for the determination of antibacterial residues in foods, making special emphasis in on-line, high-throughput, multi-class methods and including several applications in detail.

  7. One-pot preparation of glutathione-silica hybrid monolith for mixed-mode capillary liquid chromatography based on "thiol-ene" click chemistry.

    Science.gov (United States)

    Lin, Zian; Tan, Xiaoqing; Yu, Ruifang; Lin, Jiashi; Yin, Xiaofei; Zhang, Lan; Yang, Huanghao

    2014-08-15

    A novel glutathione (GSH)-silica hybrid monolithic column synthesized via a combination of thiol-ene click reaction and one-pot process was described, where thiol-end GSH organic monomer and 2,2-azobisisobutyronitrile (AIBN) were mixed with hydrolyzed tetramethyloxysilane (TMOS) and γ-methacryloxypropyltrimethoxysilane (γ-MAPS) and then introduced into a fused-silica capillary for simultaneous polycondensation and "thiol-ene" click reaction to form the GSH-silica hybrid monolith. The effects of the molar ratio of TMOS/γ-MAPS, the amount of GSH, and the volume of porogen on the morphology, permeability and pore properties of the prepared GSH-silica hybrid monoliths were studied in detail. A uniform monolithic network with high porosity was obtained. A series of test compounds including alkylbenzenes, amides, and anilines were used to evaluate the retention behaviors of the GSH-silica hybrid monolithic column. The results demonstrated that the prepared GSH-silica hybrid monolith exhibited multiple interactions including hydrophobicity, hydrophilicity, as well as cation exchange interaction. The run-to-run, column-to-column and batch-to-batch reproducibilities of the GSH-silica hybrid monolith for phenols' retention were satisfactory with the relative standard deviations (RSDs) less than 1.3% (n=5), 2.6% (n=3) and 3.2% (n=3), respectively, indicating the effectiveness and practicability of the proposed method. In addition, the GSH-silica hybrid monolith was applied to the separation of nucleotides, peptides and protein tryptic digests, respectively. The successful applications suggested the potential of the GSH-silica hybrid monolith in complex sample analysis.

  8. Highly selective and sensitive determination of several antioxidants in human breast milk using high-performance liquid chromatography based on Ag(III) complex chemiluminescence detection.

    Science.gov (United States)

    Ma, Li; Shi, Hongmei; Lian, Kaoqi; Diao, Yingfei; Chen, Yang; Ma, Chunling; Kang, Weijun

    2017-03-01

    Ascorbic acid (AA), uric acid (UA) and glutathione (GSH) are the most important water-soluble antioxidants. The concentrations of GSH and glutathione disulfide (GSSG) and their molar ratio are the indicators of oxidative stress. Little is known about the contents of UA, GSH and GSSG in human milk; a reliable and sensitive method to monitor the concentrations of the four compounds simultaneously in human milk is of critical importance. A new method for separation and quantification of these water-soluble antioxidants by HPLC coupled with Ag(III) chemiluminescence detector has been developed in this work with better recoveries. The antioxidants contents were determined in different times of lactation utilizing this method. The results show that the levels of AA, UA, GSH and GSH/GSSG of human colostrum are significantly higher than those of mature milk (Pantioxidants than mature milk. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Influence of Lossy Compressed DEM on Radiometric Correction for Land Cover Classification of Remote Sensing Images

    Science.gov (United States)

    Moré, G.; Pesquer, L.; Blanes, I.; Serra-Sagristà, J.; Pons, X.

    2012-12-01

    World coverage Digital Elevation Models (DEM) have progressively increased their spatial resolution (e.g., ETOPO, SRTM, or Aster GDEM) and, consequently, their storage requirements. On the other hand, lossy data compression facilitates accessing, sharing and transmitting large spatial datasets in environments with limited storage. However, since lossy compression modifies the original information, rigorous studies are needed to understand its effects and consequences. The present work analyzes the influence of DEM quality -modified by lossy compression-, on the radiometric correction of remote sensing imagery, and the eventual propagation of the uncertainty in the resulting land cover classification. Radiometric correction is usually composed of two parts: atmospheric correction and topographical correction. For topographical correction, DEM provides the altimetry information that allows modeling the incidence radiation on terrain surface (cast shadows, self shadows, etc). To quantify the effects of the DEM lossy compression on the radiometric correction, we use radiometrically corrected images for classification purposes, and compare the accuracy of two standard coding techniques for a wide range of compression ratios. The DEM has been obtained by resampling the DEM v.2 of Catalonia (ICC), originally having 15 m resolution, to the Landsat TM resolution. The Aster DEM has been used to fill the gaps beyond the administrative limits of Catalonia. The DEM has been lossy compressed with two coding standards at compression ratios 5:1, 10:1, 20:1, 100:1 and 200:1. The employed coding standards have been JPEG2000 and CCSDS-IDC; the former is an international ISO/ITU-T standard for almost any type of images, while the latter is a recommendation of the CCSDS consortium for mono-component remote sensing images. Both techniques are wavelet-based followed by an entropy-coding stage. Also, for large compression ratios, both techniques need a post processing for correctly

  10. Results from the radiometric validation of Sentinel-3 optical sensors using natural targets

    Science.gov (United States)

    Fougnie, Bertrand; Desjardins, Camille; Besson, Bruno; Bruniquel, Véronique; Meskini, Naceur; Nieke, Jens; Bouvet, Marc

    2016-09-01

    The recently launched SENTINEL-3 mission measures sea surface topography, sea/land surface temperature, and ocean/land surface colour with high accuracy. The mission provides data continuity with the ENVISAT mission through acquisitions by multiple sensing instruments. Two of them, OLCI (Ocean and Land Colour Imager) and SLSTR (Sea and Land Surface Temperature Radiometer) are optical sensors designed to provide continuity with Envisat's MERIS and AATSR instruments. During the commissioning, in-orbit calibration and validation activities are conducted. Instruments are in-flight calibrated and characterized primarily using on-board devices which include diffusers and black body. Afterward, vicarious calibration methods are used in order to validate the OLCI and SLSTR radiometry for the reflective bands. The calibration can be checked over dedicated natural targets such as Rayleigh scattering, sunglint, desert sites, Antarctica, and tentatively deep convective clouds. Tools have been developed and/or adapted (S3ETRAC, MUSCLE) to extract and process Sentinel-3 data. Based on these matchups, it is possible to provide an accurate checking of many radiometric aspects such as the absolute and interband calibrations, the trending correction, the calibration consistency within the field-of-view, and more generally this will provide an evaluation of the radiometric consistency for various type of targets. Another important aspect will be the checking of cross-calibration between many other instruments such as MERIS and AATSR (bridge between ENVISAT and Sentinel-3), MODIS (bridge to the GSICS radiometric standard), as well as Sentinel-2 (bridge between Sentinel missions). The early results, based on the available OLCI and SLSTR data, will be presented and discussed.

  11. Radiometric model for the stereo camera STC onboard the BepiColombo ESA mission

    Science.gov (United States)

    Da Deppo, Vania; Martellato, Elena; Simioni, Emanuele; Naletto, Giampiero; Cremonese, Gabriele

    2016-08-01

    The STereoscopic imaging Channel (STC) is one of the instruments on-board the BepiColombo mission, which is an ESA/JAXA Cornerstone mission dedicated to the investigation of the Mercury planet. STC is part of the Spectrometers and Imagers for MPO BepiColombo Integrated Observatory SYStem (SIMBIO-SYS) suite. STC main scientific objective is the 3D global mapping of the entire surface of Mercury with a mean scale factor of 55 m per pixel at periherm. To determine the design requirements and to model the on-ground and in-flight performance of STC, a radiometric model has been developed. In particular, STC optical characteristics have been used to define the instrument response function. As input for the model, different sources can be taken into account depending on the applications, i.e. to simulate the in-flight or on-ground performances. Mercury expected radiance, the measured Optical Ground Support Equipment (OGSE) integrating sphere radiance, or calibrated stellar fluxes can be considered. Primary outputs of the model are the expected signal per pixel expressed in function of the integration time and its signal-to-noise ratio (SNR). These outputs allow then to calculate the most appropriate integration times to be used during the different phases of the mission; in particular for the images taken during the calibration campaign on-ground and for the in-flight ones, i.e. surface imaging along the orbit around Mercury and stellar calibration acquisitions. This paper describes the radiometric model structure philosophy, the input and output parameters and presents the radiometric model derived for STC. The predictions of the model will be compared with some measurements obtained during the Flight Model (FM) ground calibration campaign. The results show that the model is valid, in fact the foreseen simulated values are in good agreement with the real measured ones.

  12. Detection of anti-tuberculosis activity in some folklore plants by radiometric BACTEC assay.

    Science.gov (United States)

    Gupta, V K; Shukla, C; Bisht, G R S; Saikia, D; Kumar, S; Thakur, R L

    2011-01-01

    The anti-tubercular drugs are less effective because of the emergence of multi-drug resistant (MDR) and extensively drug resistant (XDR) strains of M. tuberculosis, so plants being an alternative source of anti-microbial compounds. The aim of this study was to investigate anti-tuberculosis potential of the plants using Mycobacterium smegmatis as a rapid screening model for detection of anti-mycobacterial activity and further to evaluate the active plants for anti-tuberculosis activity against M. tuberculosis using radiometric BACTEC assay. The 15 plants were screened for anti-mycobacterial activity against M. smegmatis by the disk diffusion assay. The ethanolic extracts of Mallotus philippensis, Vitex negundo, Colebrookea oppositifolia, Rumex hastatus, Mimosa pudica, Kalanchoe integra and Flacourtia ramontchii were active against M. smegmatis in primary screening. The anti-tuberculosis potential was identified in the leaves extracts of Mallotus philippensis by radiometric BACTEC assay. The ethanolic extract of M. philippensis showed anti-tuberculosis activity against virulent and avirulent strains of M. tuberculosis H(37) Rv and M. tuberculosis H(37) Ra with minimum inhibitory concentration 0·25 and 0·125 mg ml(-1), respectively. The inhibition in growth index values of M. tuberculosis was observed in the presence of ethyl acetate fraction at a minimum concentration of 0·05 mg ml(-1). We found that BACTEC radiometric assay is a valuable method for detection of anti-tuberculosis activity of the plant extracts. The results indicate that ethanolic extract and ethyl acetate fraction of M. philippensis exhibited significant anti-mycobacterial activity against M. tuberculosis. These findings provide scientific evidence to support the traditional medicinal uses of M. philippensis and indicate a promising potential of this plant for the development of anti-tuberculosis agent. © 2010 The Authors. Letters in Applied Microbiology © 2010 The Society for Applied

  13. Analysis of Sentinel-1 Radiometric Stability and Quality for Land Surface Applications

    Directory of Open Access Journals (Sweden)

    Mohammad El Hajj

    2016-05-01

    Full Text Available Land monitoring using temporal series of Synthetic Aperture Radar (SAR images requires radiometrically well calibrated sensors. In this paper, the radiometric stability of the new SAR Sentinel-1A “S-1A” sensor was first assessed by analyzing temporal variations of the backscattering coefficient (σ° returned from invariant targets. Second, the radiometric level of invariant targets was compared from S-1A and Radarsat-2 “RS-2” data. The results show three stable sub-time series of S-1A data. The first (between 1 October 2014 and 19 March 2015 and third (between 25 November 2015 and 1 February 2016 sub-time series have almost the same mean σ°-values (a difference lower than 0.3 dB. The mean σ°-value of the second sub-time series (between 19 March 2015 and 25 November 2015 is higher than that of the first and the third sub-time series by roughly 0.9 dB. Moreover, our results show that the stability of each sub-time series is better than 0.48 dB. In addition, the results show that S-1A images of the first and third sub-time series appear to be well calibrated in comparison to RS-2 data, with a difference between S-1A and RS-2 lower than 0.3 dB. However, the S-1A images of the second sub-time series have σ°-values that are higher than those from RS-2 by roughly 1 dB.

  14. L5 TM radiometric recalibration procedure using the internal calibration trends from the NLAPS trending database

    Science.gov (United States)

    Chander, G.; Haque, Md. O.; Micijevic, E.; Barsi, J.A.

    2008-01-01

    From the Landsat program's inception in 1972 to the present, the earth science user community has benefited from a historical record of remotely sensed data. The multispectral data from the Landsat 5 (L5) Thematic Mapper (TM) sensor provide the backbone for this extensive archive. Historically, the radiometric calibration procedure for this imagery used the instrument's response to the Internal Calibrator (IC) on a scene-by-scene basis to determine the gain and offset for each detector. The IC system degraded with time causing radiometric calibration errors up to 20 percent. In May 2003 the National Landsat Archive Production System (NLAPS) was updated to use a gain model rather than the scene acquisition specific IC gains to calibrate TM data processed in the United States. Further modification of the gain model was performed in 2007. L5 TM data that were processed using IC prior to the calibration update do not benefit from the recent calibration revisions. A procedure has been developed to give users the ability to recalibrate their existing Level-1 products. The best recalibration results are obtained if the work order report that was originally included in the standard data product delivery is available. However, many users may not have the original work order report. In such cases, the IC gain look-up table that was generated using the radiometric gain trends recorded in the NLAPS database can be used for recalibration. This paper discusses the procedure to recalibrate L5 TM data when the work order report originally used in processing is not available. A companion paper discusses the generation of the NLAPS IC gain and bias look-up tables required to perform the recalibration.

  15. Spatial and radiometric characterization of multi-spectrum satellite images through multi-fractal analysis

    Science.gov (United States)

    Alonso, Carmelo; Tarquis, Ana M.; Zúñiga, Ignacio; Benito, Rosa M.

    2017-03-01

    Several studies have shown that vegetation indexes can be used to estimate root zone soil moisture. Earth surface images, obtained by high-resolution satellites, presently give a lot of information on these indexes, based on the data of several wavelengths. Because of the potential capacity for systematic observations at various scales, remote sensing technology extends the possible data archives from the present time to several decades back. Because of this advantage, enormous efforts have been made by researchers and application specialists to delineate vegetation indexes from local scale to global scale by applying remote sensing imagery. In this work, four band images have been considered, which are involved in these vegetation indexes, and were taken by satellites Ikonos-2 and Landsat-7 of the same geographic location, to study the effect of both spatial (pixel size) and radiometric (number of bits coding the image) resolution on these wavelength bands as well as two vegetation indexes: the Normalized Difference Vegetation Index (NDVI) and the Enhanced Vegetation Index (EVI). In order to do so, a multi-fractal analysis of these multi-spectral images was applied in each of these bands and the two indexes derived. The results showed that spatial resolution has a similar scaling effect in the four bands, but radiometric resolution has a larger influence in blue and green bands than in red and near-infrared bands. The NDVI showed a higher sensitivity to the radiometric resolution than EVI. Both were equally affected by the spatial resolution. From both factors, the spatial resolution has a major impact in the multi-fractal spectrum for all the bands and the vegetation indexes. This information should be taken in to account when vegetation indexes based on different satellite sensors are obtained.

  16. Radiometric trend of lunar calibration compared with vicarious calibration for GOSAT

    Science.gov (United States)

    Shiomi, K.; Kawakami, S.; Kuze, A.; Suto, H.; Hashiguchi, T.; Kataoka, F.; Higuchi, R.; Bruegge, C. J.; Schwandner, F. M.; Chapsky, L.

    2014-12-01

    GOSAT observes a nearly full moon for the on-orbit radiometric calibration of the FTS SWIR bands and the CAI. Lunar calibrations are operated in April/May for investigation of continuous annual radiometric trends and in June/July, corresponding to the annual Railroad Valley Cal/Val campaign. JAXA's Greenhouse Gases Observing Satellite (GOSAT) is since 2009 in polar orbit to monitor greenhouse gases such as CO2 and CH4 from space. GOSAT consists of a Fourier Transform Spectrometer (TANSO-FTS) and a Cloud and Aerosol Imager (TANSO-CAI). The FTS has 3 polarized SWIR narrow bands and a TIR wide band. The FTS observes globally with gridded points of 10 km FOV using discrete pointing. The CAI carries 4 radiometers in the UV to SWIR with high spatial resolution of 0.5-1.5 km and a wide swath of 1000 km. Since the 3rd year, lunar calibration has been planned to observe at a phase angle around 7 degrees from normal incidence. This choice avoids the reflectance opposition surge in order to target the nearly-unchanged and brightest reflectance as a function of phase angle. The Railroad Valley vicarious calibration campaign is conducted by measuring the surface reflectance and atmospheric parameters coincident with a dedicated GOSAT target observation, to derive top-of-the-atmosphere radiance. The nadir surface reflectance is collected in 500x500 m areas corresponding to the CAI resolution. The off-nadir reflectance is measured simultaneously with BRDF values, for correction. We will summarize the radiometric study of the GOSAT lunar calibration compared with the vicarious calibration. In-flight coincident calibration activities will continue with GOSAT and OCO-2.

  17. A novel solution for car traffic control based on radiometric microwave devices

    Science.gov (United States)

    Soldovieri, Francesco; Denisov, Alexander; Speziale, Victor

    2014-05-01

    The significant problem of traffic in big cities, connected with huge and building up quantity of automobile cars, demands for novel strategies, based on nonconventional solutions, in order to improve system traffic control, especially at crossroads. As well known, the usual solution is based on the time relay, which requires the installation of a fixed traffic interval (signal light switching) at a crossroad; this solution is low cost, but does not account for the actual traffic conditions. Therefore, in the recent years, attention is towards to new designs, where the monitoring of the and control of traffic is carried out by using various methods including, optical, the infrared, magnetic, radar tracking, acoustical ones. In this work, we discuss the deployment of high sensitivity radiometric systems and radiometers(sensor) in the microwave range [1, 2]. In fact, the radiometer as "sensor" can provide an always updated information about the car traffic in any weather condition and in absence or low visibility conditions. In fact, the radiometric sensor detects the cars thanks to the different behavior of the car roofs which reflect the cold sky whereas the road asphalt is visible as warm object (at around outside temperature). [1] A. G. Denisov, V. P. Gorishnyak, S. E. Kuzmin et al., "Some experiments concerning resolution of 32 sensors passive 8mm wave imaging system," in Proceedings of the International Symposium on Space Terahertz Technology (ISSTT '09), Charlottesville, Va, USA, April 2009. [2] F. Soldovieri, A. Natale, V. Gorishnyak, A. Pavluchenko, A. Denisov, and L. Chen, "Radiometric Imaging for Monitoring and Surveillance Issues," International Journal of Antennas and Propagation, vol. 2013, Article ID 272561, 8 pages, 2013. doi:10.1155/2013/272561.

  18. Titan Density Reconstruction Using Radiometric and Cassini Attitude Control Flight Data

    Science.gov (United States)

    Andrade, Luis G., Jr.; Burk, Thomas A.

    2015-01-01

    This paper compares three different methods of Titan atmospheric density reconstruction for the Titan 87 Cassini flyby. T87 was a unique flyby that provided independent Doppler radiometric measurements on the ground throughout the flyby including at Titan closest approach. At the same time, the onboard accelerometer provided an independent estimate of atmospheric drag force and density during the flyby. These results are compared with the normal method of reconstructing atmospheric density using thruster on-time and angular momentum accumulation. Differences between the estimates are analyzed and a possible explanation for the differences is evaluated.

  19. Analysis of radiometric signal in sedimentating suspension flow in open channel

    Directory of Open Access Journals (Sweden)

    Zych Marcin

    2015-01-01

    Full Text Available The article discusses issues related to the estimation of the sedimentating solid particles average flow velocity in an open channel using radiometric methods. Due to the composition of the compound, which formed water and diatomite, received data have a very weak signal to noise ratio. In the process analysis the known determining of the solid phase transportation time delay the classical cross-correlation function is the most reliable method. The use of advanced frequency analysis based on mutual spectral density function and wavelet transform of recorded signals allows a reduction of the noise contribution.

  20. Analysis of radiometric signal in sedimentating suspension flow in open channel

    Science.gov (United States)

    Zych, Marcin; Hanus, Robert; Petryka, Leszek; Świsulski, Dariusz; Doktor, Marek; Mastej, Wojciech

    2015-05-01

    The article discusses issues related to the estimation of the sedimentating solid particles average flow velocity in an open channel using radiometric methods. Due to the composition of the compound, which formed water and diatomite, received data have a very weak signal to noise ratio. In the process analysis the known determining of the solid phase transportation time delay the classical cross-correlation function is the most reliable method. The use of advanced frequency analysis based on mutual spectral density function and wavelet transform of recorded signals allows a reduction of the noise contribution.

  1. On-Orbit Radiometric Performance of the Landsat 8 ThermalInfrared Sensor

    Directory of Open Access Journals (Sweden)

    Matthew Montanaro

    2014-11-01

    Full Text Available The Thermal Infrared Sensor (TIRS requirements for noise, stability, and uniformity were designed to ensure the radiometric integrity of the data products. Since the launch of Landsat 8 in February 2013, many of these evaluations have been based on routine measurements of the onboard calibration sources, which include a variable-temperature blackbody and a deep space view port. The noise equivalent change in temperature (NEdT of TIRS data is approximately 0.05 K @ 300 K in both bands, exceeding requirements by about a factor of 8 and Landsat 7 ETM+ performance by a factor of 3. Coherent noise is not readily apparent in TIRS data. No apparent change in the detector linearization has been observed. The radiometric stability of the TIRS instrument over the period between radiometric calibrations (about 40 min is less than one count of dark current and the variation in terms of radiance is less than 0.015 \\(W/m^2/sr/\\mu m\\ (or 0.13 K at 300 K, easily meeting the short term stability requirements. Long term stability analysis has indicated a degradation of about 0.2% or less per year. The operational calibration is only updated using the biases taken every orbit, due to the fundamental stability of the instrument. By combining the data from two active detector rows per band, 100% detector operability is maintained for the instrument. No trends in the noise, operability, or short term radiometric stability are apparent over the mission life. The uniformity performance is more difficult to evaluate as scene-varying banding artifacts have been observed in Earth imagery. Analyses have shown that stray light is affecting the recorded signal from the Earth and inducing the banding depending on the content of the surrounding Earth surface. As the stray light effects are stronger in the longer wavelength TIRS band11 (12.0 \\(\\mu m\\, the uniformity is better in the shorter wavelength band10 (10.9 \\(\\mu m\\. Both bands have exceptional noise and

  2. Titan Density Reconstruction Using Radiometric and Cassini Attitude Control Flight Data

    Science.gov (United States)

    Andrade, Luis G., Jr.; Burk, Thomas A.

    2015-01-01

    This paper compares three different methods of Titan atmospheric density reconstruction for the Titan 87 Cassini flyby. T87 was a unique flyby that provided independent Doppler radiometric measurements on the ground throughout the flyby including at Titan closest approach. At the same time, the onboard accelerometer provided an independent estimate of atmospheric drag force and density during the flyby. These results are compared with the normal method of reconstructing atmospheric density using thruster on-time and angular momentum accumulation. Differences between the estimates are analyzed and a possible explanation for the differences is evaluated.

  3. A Kalman Approach to Lunar Surface Navigation using Radiometric and Inertial Measurements

    Science.gov (United States)

    Chelmins, David T.; Welch, Bryan W.; Sands, O. Scott; Nguyen, Binh V.

    2009-01-01

    Future lunar missions supporting the NASA Vision for Space Exploration will rely on a surface navigation system to determine astronaut position, guide exploration, and return safely to the lunar habitat. In this report, we investigate one potential architecture for surface navigation, using an extended Kalman filter to integrate radiometric and inertial measurements. We present a possible infrastructure to support this technique, and we examine an approach to simulating navigational accuracy based on several different system configurations. The results show that position error can be reduced to 1 m after 5 min of processing, given two satellites, one surface communication terminal, and knowledge of the starting position to within 100 m.

  4. CrIS Sensor Temperature Effects on CrIS Radiometric Performance

    OpenAIRE

    Esplin, Mark; Zavyalov, Vladimir; Grant, Kevin; Scott, Deron

    2012-01-01

    The Cross-track Infrared Sounder (CrIS) sensor was launched on the Suomi NPP spacecraft October 28, 2011. The CrIS sensor is a Michelson interferometer with a 3 x 3 detectors for each of three spectral bands: LWIR 650-1095 wavenumbers, MWIR 1210-1750 wavenumbers and SWIR 2155-2550 wavenumbers. The CrIS sensor is performing very well and is generally exceeding the noise, radiometric and spectral performance requirements for its primary weather sensing mission. However, for climate change appli...

  5. Radiometric and spectral calibrations of the Geostationary Imaging Fourier Transform Spectrometer (GIFTS) using principle component analysis

    Science.gov (United States)

    Tian, Jialin; Smith, William L.; Gazarik, Michael J.

    2008-10-01

    The ultimate remote sensing benefits of the high resolution Infrared radiance spectrometers will be realized with their geostationary satellite implementation in the form of imaging spectrometers. This will enable dynamic features of the atmosphere's thermodynamic fields and pollutant and greenhouse gas constituents to be observed for revolutionary improvements in weather forecasts and more accurate air quality and climate predictions. As an important step toward realizing this application objective, the Geostationary Imaging Fourier Transform Spectrometer (GIFTS) Engineering Demonstration Unit (EDU) was successfully developed under the NASA New Millennium Program, 2000-2006. The GIFTS-EDU instrument employs three focal plane arrays (FPAs), which gather measurements across the long-wave IR (LWIR), short/mid-wave IR (SMWIR), and visible spectral bands. The raw GIFTS interferogram measurements are radiometrically and spectrally calibrated to produce radiance spectra, which are further processed to obtain atmospheric profiles via retrieval algorithms. The radiometric calibration is achieved using internal blackbody calibration references at ambient (260 K) and hot (286 K) temperatures. The absolute radiometric performance of the instrument is affected by several factors including the FPA off-axis effect, detector/readout electronics induced nonlinearity distortions, and fore-optics offsets. The GIFTS-EDU, being the very first imaging spectrometer to use ultra-high speed electronics to readout its large area format focal plane array detectors, operating at wavelengths as large as 15 microns, possessed non-linearity's not easily removable in the initial calibration process. In this paper, we introduce a refined calibration technique that utilizes Principle Component (PC) analysis to compensate for instrument distortions and artifacts remaining after the initial radiometric calibration process, thus, further enhance the absolute calibration accuracy. This method is

  6. Vicarious Radiometric Calibration of a Multispectral Camera on Board an Unmanned Aerial System

    Directory of Open Access Journals (Sweden)

    Susana Del Pozo

    2014-02-01

    Full Text Available Combinations of unmanned aerial platforms and multispectral sensors are considered low-cost tools for detailed spatial and temporal studies addressing spectral signatures, opening a broad range of applications in remote sensing. Thus, a key step in this process is knowledge of multi-spectral sensor calibration parameters in order to identify the physical variables collected by the sensor. This paper discusses the radiometric calibration process by means of a vicarious method applied to a high-spatial resolution unmanned flight using low-cost artificial and natural covers as control and check surfaces, respectively.

  7. Algorithms for Relative Radiometric Correction in Earth Observing Systems Resource-P and Canopus-V

    Science.gov (United States)

    Zenin, V. A.; Eremeev, V. V.; Kuznetcov, A. E.

    2016-06-01

    The present paper has considered two algorithms of the relative radiometric correction of information obtained from a multimatrix imagery instrument of the spacecraft "Resource-P" and frame imagery systems of the spacecraft "Canopus-V". The first algorithm is intended for elimination of vertical stripes on the image that are caused by difference in transfer characteristics of CCD matrices and CCD detectors. Correction coefficients are determined on the basis of analysis of images that are homogeneous by brightness. The second algorithm ensures an acquisition of microframes homogeneous by brightness from which seamless images of the Earth surface are synthesized. Examples of practical usage of the developed algorithms are mentioned.

  8. FPGA-based data processing module design of on-board radiometric calibration in visible/near infrared bands

    Science.gov (United States)

    Zhou, Guoqing; Li, Chenyang; Yue, Tao; Liu, Na; Jiang, Linjun; Sun, Yue; Li, Mingyan

    2015-12-01

    FPGA technology has long been applied to on-board radiometric calibration data processing however the integration of FPGA program is not good enough. For example, some sensors compressed remote sensing images and transferred to ground station to calculate the calibration coefficients. It will affect the timeliness of on-board radiometric calibration. This paper designs an integrated flow chart of on-board radiometric calibration. Building FPGA-based radiometric calibration data processing modules uses system generator. Thesis focuses on analyzing the calculation accuracy of FPGA-based two-point method and verifies the feasibility of this method. Calibration data was acquired by hardware platform which was built using integrating sphere, CMOS camera (canon 60d), ASD spectrometers and light filter (center wavelength: 690nm, bandwidth: 45nm). The platform can simulate single-band on-board radiometric calibration data acquisition in visible/near infrared band. Making an experiment of calibration coefficients calculation uses obtained data and FPGA modules. Experimental results show that: the camera linearity is above 99% meeting the experimental requirement. Compares with MATLAB the calculation accuracy of two-point method by FPGA are as follows: the error of gain value is 0.0053%; the error of offset value is 0.00038719%. Those results meet experimental accuracy requirement.

  9. PHASS99: A software program for retrieving and decoding the radiometric ages of igneous rocks from the international database IGBADAT

    Science.gov (United States)

    Al-Mishwat, Ali T.

    2016-05-01

    PHASS99 is a FORTRAN program designed to retrieve and decode radiometric and other physical age information of igneous rocks contained in the international database IGBADAT (Igneous Base Data File). In the database, ages are stored in a proprietary format using mnemonic representations. The program can handle up to 99 ages in an igneous rock specimen and caters to forty radiometric age systems. The radiometric age alphanumeric strings assigned to each specimen description in the database consist of four components: the numeric age and its exponential modifier, a four-character mnemonic method identification, a two-character mnemonic name of analysed material, and the reference number in the rock group bibliography vector. For each specimen, the program searches for radiometric age strings, extracts them, parses them, decodes the different age components, and converts them to high-level English equivalents. IGBADAT and similarly-structured files are used for input. The output includes three files: a flat raw ASCII text file containing retrieved radiometric age information, a generic spreadsheet-compatible file for data import to spreadsheets, and an error file. PHASS99 builds on the old program TSTPHA (Test Physical Age) decoder program and expands greatly its capabilities. PHASS99 is simple, user friendly, fast, efficient, and does not require users to have knowledge of programing.

  10. Analysis of Properties of Reflectance Reference Targets for Permanent Radiometric Test Sites of High Resolution Airborne Imaging Systems

    Directory of Open Access Journals (Sweden)

    Eero Ahokas

    2010-08-01

    Full Text Available Reliable and optimal exploitation of rapidly developing airborne imaging methods requires geometric and radiometric quality assurance of production systems in operational conditions. Permanent test sites are the most promising approach for cost-efficient performance assessment. Optimal construction of permanent radiometric test sites for high resolution airborne imaging systems is an unresolved issue. The objective of this study was to assess the performance of commercially available gravels and painted and unpainted concrete targets for permanent, open-air radiometric test sites under sub-optimal climate conditions in Southern Finland. The reflectance spectrum and reflectance anisotropy and their stability were characterized during the summer of 2009. The management of reflectance anisotropy and stability were shown to be the key issues for better than 5% reflectance accuracy.

  11. [In-flight absolute radiometric calibration of UAV hyperspectral camera and its validation analysis].

    Science.gov (United States)

    Gou, Zhi-yang; Yan, Lei; Chen, Wei; Jing, Xin; Yin, Zhong-yi; Duan, Yi-ni

    2012-02-01

    With the data in Urad Front Banner, Inner Mongolia on November 14th, 2010, hyper-spectral camera on UAV was calibrated adopting reflectance-based method. During the in-flight absolute radiometric calibration, 6 hyper-spectral radiometric gray-scale targets were arranged in the validation field. These targets' reflectances are 4.5%, 20%, 30%, 40%, 50% and 60% separately. To validate the calibration result, four extra hyper-spectral targets with sharp-edge spectrum were arranged to simulate the reflection and absorption peaks in natural objectives. With these peaks, the apparent radiance calculated by radiation transfer model and that calculated through calibration coefficients are much different. The result shows that in the first 15 bands (blue bands), errors are somewhat huge due to the noises of equipment. In the rest bands with quite even spectrum, the errors are small, most of which are less than 10%. For those bands with sharp changes in spectral curves, the errors are quite considerable, varying from 10% to 25%.

  12. Measurements and analysis of solar direct irradiance-meter on Dunhuang radiometric calibration sites

    Science.gov (United States)

    Liu, En-chao; Li, Xin; Zhang, Yan-na; Zheng, Xiao-bing; Yan, Jing

    2016-10-01

    In order to realize the quantitative application of satellite remote sensing data and adapt to the demand of field calibration of hyper-spectral remote sensors, the solar direct spectral irradiance-meter was developed. According to the sampling principle of spectral irradiance, the irradiance-meter was designed with some technical improvements, the radiometric calibration based on system-level detector were adopted. Irradiance-meter took part in field calibration experiment on Dunhuang radiometric calibration sites and the correct data results were collected. The measurement results of spectral irradiance were consistent with simulated ground irradiance by MODTRAN model. The relative deviation of atmospheric optical depth(AOD) compared with solar radiometer CE318 was less than 4.84%. The whole day results of the irradiance observations and atmospheric transmission in the data applications were collected, the local atmosphere mode and the change of environment were reflected accurately, the input information of the atmospheric parameter were provided for the study of atmospheric properties and field calibration of remote sensors.

  13. Radiometric assay of red cell and plasma cholinesterase in pesticide appliers from Minnesota.

    Science.gov (United States)

    Potter, W T; Garry, V F; Kelly, J T; Tarone, R; Griffith, J; Nelson, R L

    1993-03-01

    In this study we demonstrate the uses of radiometric assay to detect anticholinesterases in a human population (N = 80) exposed to a broad spectrum of pesticides. The assay is nondilutional. Therefore, anticholinesterase (AChE) agents with low binding affinity can be detected. Our initial results show statistically significant exposure-related decreases in either red cell (AChE) or plasma cholinesterase activity ((butyrl)cholinesterase; BuChE) occurred not only among pesticide appliers who use organophosphates, but also among appliers of the fumigant phosphine. These data extend earlier observations made in laboratory animals exposed to this fumigant. Significant exposure-related decreases in AChE activity were seen in herbicide appliers and appear to be associated with exposure to the herbicide 2-methoxy-3,6-dichlorobenzoic acid. There was no evidence of exposure-related decreases in BuChE activity in herbicide appliers. Our in vivo data, coupled with preliminary in vitro studies of phosphine (50% AChE inhibition, 10 ppm) and 2-methoxy-3,6-chlorobenzoic acid (50% AChE and BuChE inhibition, 70 ppm), suggest that the radiometric assay may be used to detect a broader spectrum of biologically active anticholinesterase agents.

  14. Progress in the determination of some astronomical constants from radiometric observations of planets and spacecraft

    Science.gov (United States)

    Pitjeva, E. V.

    2001-05-01

    Modern radiometric observations of planets, beginning in 1961, make it possible to determine and improve a broad set of astronomical constants from the value of the astronomical unit (AU) to parameters of PPN formalism. Three main factors that influence the progress in the determination of astronomical constants - 1) reductions of the observational data, 2) dynamical models of planet motion, 3) observational data themselves - are demonstrated in this paper. The reduction of the measurements included all relevant corrections, including the modeling of the topography of Mercury and Venus which reduced the rms residuals for observations by 14.5% and 23% correspondingly. The formal standard deviations of the solution elements of the planets and the AU are improved by 30-50% using the DE405 or EPM2000 ephemerides constructed in IAA (Russia) instead of DE200. It was shown that including the measurements of the Viking and Pathfinder landers, being free from the uncertainties due to planetary topography, into the observational data reduces the uncertainties of adjusted parameters by 1-2 orders. The astronomical constants obtained in the fitting process of the DE405 and EPM2000 ephemerides to data totaling more 80 000 radiometric observations of planets and spacecraft are given.

  15. METHOD OF RADIOMETRIC DISTORTION CORRECTION OF MULTISPECTRAL DATA FOR THE EARTH REMOTE SENSING

    Directory of Open Access Journals (Sweden)

    A. N. Grigoriev

    2015-07-01

    Full Text Available The paper deals with technologies of ground secondary processing of heterogeneous multispectral data. The factors of heterogeneous data include uneven illumination of objects on the Earth surface caused by different properties of the relief. A procedure for the image restoration of spectral channels by means of terrain distortion compensation is developed. The object matter of this paper is to improve the quality of the results during image restoration of areas with large and medium landforms. Methods. Researches are based on the elements of the digital image processing theory, statistical processing of the observation results and the theory of multi-dimensional arrays. Main Results. The author has introduced operations on multidimensional arrays: concatenation and elementwise division. Extended model description for input data about the area is given. The model contains all necessary data for image restoration. Correction method for multispectral data radiometric distortions of the Earth remote sensing has been developed. The method consists of two phases: construction of empirical dependences for spectral reflectance on the relief properties and restoration of spectral images according to semiempirical data. Practical Relevance. Research novelty lies in developme nt of the application theory of multidimensional arrays with respect to the processing of multispectral data, together with data on the topography and terrain objects. The results are usable for development of radiometric data correction tools. Processing is performed on the basis of a digital terrain model without carrying out ground works connected with research of the objects reflective properties.

  16. JPSS-1 VIIRS Radiometric Characterization and Calibration Based on Pre-Launch Testing

    Directory of Open Access Journals (Sweden)

    Hassan Oudrari

    2016-01-01

    Full Text Available The Visible Infrared Imaging Radiometer Suite (VIIRS on-board the first Joint Polar Satellite System (JPSS completed its sensor level testing on December 2014. The JPSS-1 (J1 mission is scheduled to launch in December 2016, and will be very similar to the Suomi-National Polar-orbiting Partnership (SNPP mission. VIIRS instrument has 22 spectral bands covering the spectrum between 0.4 and 12.6 μm. It is a cross-track scanning radiometer capable of providing global measurements twice daily, through observations at two spatial resolutions, 375 m and 750 m at nadir for the imaging and moderate bands, respectively. This paper will briefly describe J1 VIIRS characterization and calibration performance and methodologies executed during the pre-launch testing phases by the government independent team to generate the at-launch baseline radiometric performance and the metrics needed to populate the sensor data record (SDR Look-Up-Tables (LUTs. This paper will also provide an assessment of the sensor pre-launch radiometric performance, such as the sensor signal to noise ratios (SNRs, radiance dynamic range, reflective and emissive bands calibration performance, polarization sensitivity, spectral performance, response-vs-scan (RVS, and scattered light response. A set of performance metrics generated during the pre-launch testing program will be compared to both the VIIRS sensor specification and the SNPP VIIRS pre-launch performance.

  17. The importance of geoprocessing tools in radiometric monitoring of large areas

    Energy Technology Data Exchange (ETDEWEB)

    Dias, Danila Carrijo da Silva [Universidade Federal de Alfenas (UNIFAL), Pocos de Caldas, MG (Brazil); Comissao Nacional de Energia Nuclear (LAPOC/CNEN-MG), Pocos de Caldas, MG (Brazil). Lab. de Pocos de Caldas; Silva, Nivaldo Carlos da; Alberti, Heber Luiz Caponi; Guerrero, Eder Tadeu Zenun, E-mail: ncsilva@cnen.gov.b, E-mail: heber@cnen.gov.b, E-mail: edertzg@cnen.gov.b [Comissao Nacional de Energia Nuclear (LAPOC/CNEN-MG), Pocos de Caldas, MG (Brazil). Lab. de Pocos de Caldas

    2011-07-01

    Throughout history, the natural tendency of men to physically characterize their different surroundings has played an important role on the evolution of societies. Today, that tendency combined to the development of computer technologies, has allowed the accelerated growth of the Geographical Information Systems, which permits the analysis and manipulation of spatial data from diverse sources, producing geo referenced databases. The gamma radiation, one of the main contributors of human exposure to natural radiation, is known for its high penetration energy. Today, the environmental gamma radiation is measured through radiometric tracking mobile units, allowing large scale samplings and precise assessments. As a geo processing case study, a radiometric monitoring work was conducted in the town of Aguas da Prata-SP using a tracking mobile system, composed by a scintillator detector, a GPS and a computer, all installed in a vehicle. The data made of collected points and their respective doses and geographical references were captured and stored in a computer software and then inserted and treated in a GIS environment. After a cartographic base was created using a digitalized map of Aguas da Prata, the sampled points were plotted and interpolated with the cartographic base, producing two maps that demonstrate the tracking route and the gamma radiation dose range throughout the monitored area. Geo processing tools have shown great efficiency in this study, allowing agile manipulation and management of a large quantity of data, thus promoting a spatial analysis of natural radiation levels in the studied region. (author)

  18. Combining mobile terrestrial laser scanning geometric and radiometric data to eliminate accessories in circular metro tunnels

    Science.gov (United States)

    Tan, Kai; Cheng, Xiaojun; Ju, Qiaoqiao

    2016-07-01

    Terrestrial laser scanning (TLS) is a noninvasive technique to monitor surface conditions and morphological characteristics of structures and has been successfully introduced to the regular inspection and maintenance of metro tunnels. To accurately analyze the deformation and structural conditions of a metro tunnel, nonliner points (e.g., outliers and accessories) should be detected and eliminated. Nevertheless, the accessories are attached very closely to the liner and cannot be thoroughly eliminated by three-dimensional (3D) geometric information. This study proposes to separate the liner and accessories by combining TLS geometric and radiometric information. A refitted mobile Faro Focus3D X330 system is used for data collection of a new-built metro tunnel in Hangzhou, China. The results show that the corrected intensity data are an effective physical criterion and a complementary data source to remove accessories that cannot be eliminated by geometric data. After the removal of accessories by geometric and radiometric data, the remaining liner points can accurately reflect the actual structural and deformation conditions of metro tunnels.

  19. Sensible and latent heat flux from radiometric surface temperatures at the regional scale: methodology and validation

    Directory of Open Access Journals (Sweden)

    F. Miglietta

    2009-02-01

    Full Text Available The CarboEurope Regional Experiment Strategy (CERES was designed to develop and test a range of methodologies to assess regional surface energy and mass exchange of a large study area in the south-western part of France. This paper describes a methodology to estimate sensible and latent heat fluxes on the basis of net radiation, surface radiometric temperature measurements and information obtained from available products derived from the Meteosat Second Generation (MSG geostationary meteorological satellite, weather stations and ground-based eddy covariance towers. It is based on a simplified bulk formulation of sensible heat flux that considers the degree of coupling between the vegetation and the atmosphere and estimates latent heat as the residual term of net radiation. Estimates of regional energy fluxes obtained in this way are validated at the regional scale by means of a comparison with direct flux measurements made by airborne eddy-covariance. The results show an overall good matching between airborne fluxes and estimates of sensible and latent heat flux obtained from radiometric surface temperatures that holds for different weather conditions and different land use types. The overall applicability of the proposed methodology to regional studies is discussed.

  20. Radiometric Mapping for Naturally Occurring Radioactive Materials (NORM Assessment in Mamuju, West Sulawesi

    Directory of Open Access Journals (Sweden)

    H. Syaeful

    2014-04-01

    Full Text Available Mamuju has been known to have high radiation dose rate which comes from NORM in rock and soil. Major concern is due to its location which is near inhabitant settlement area. Preliminary research has been done by environmental team which is limited to main access road only, while some remote area has left untouched. The purpose of the research is to delineate the location and distribution of thorium and uranium anomaly in Mamuju, and also to provide adequate information regarding the anomaly and high dose rate area to decision makers and stakeholders in neither local nor central government. Method applied is radiometric mapping using spectrometer RS-125 with NaI(Tl detector in the area of interest Geological Formation of Adang Volcanic, which is more than 800 square km in size. The radiometric mapping method is widely used in uranium/thorium exploration, and now has been added with the measurement of radiation dose rate which is appropriate to environmental surveys. The mapping has been successfully delineated the area of NORM or the area with thorium and uranium anomaly. Thorium and uranium anomaly are related with multi-geological-process resulting the increase of grade into several fold from its original state

  1. The moon as a radiometric reference source for on-orbit sensor stability calibration

    Science.gov (United States)

    Stone, T.C.

    2009-01-01

    The wealth of data generated by the world's Earth-observing satellites, now spanning decades, allows the construction of long-term climate records. A key consideration for detecting climate trends is precise quantification of temporal changes in sensor calibration on-orbit. For radiometer instruments in the solar reflectance wavelength range (near-UV to shortwave-IR), the Moon can be viewed as a solar diffuser with exceptional stability properties. A model for the lunar spectral irradiance that predicts the geometric variations in the Moon's brightness with ???1% precision has been developed at the U.S. Geological Survey in Flagstaff, AZ. Lunar model results corresponding to a series of Moon observations taken by an instrument can be used to stabilize sensor calibration with sub-percent per year precision, as demonstrated by the Sea-viewing Wide Field-of-view Sensor (SeaWiFS). The inherent stability of the Moon and the operational model to utilize the lunar irradiance quantity provide the Moon as a reference source for monitoring radiometric calibration in orbit. This represents an important capability for detecting terrestrial climate change from space-based radiometric measurements.

  2. Imager-to-radiometer inflight cross calibration: RSP radiometric comparison with airborne and satellite sensors

    Directory of Open Access Journals (Sweden)

    J. McCorkel

    2015-10-01

    Full Text Available This work develops a method to compare the radiometric calibration between a radiometer and imagers hosted on aircraft and satellites. The radiometer is the airborne Research Scanning Polarimeter (RSP that takes multi-angle, photo-polarimetric measurements in several spectral channels. The RSP measurements used in this work were coincident with measurements made by the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS, which was on the same aircraft. These airborne measurements were also coincident with an overpass of the Landsat 8 Operational Land Imager (OLI. First we compare the RSP and OLI radiance measurements to AVIRIS since the spectral response of the multispectral instruments can be used to synthesize a spectrally equivalent signal from the imaging spectrometer data. We then explore a method that uses AVIRIS as a transfer between RSP and OLI to show that radiometric traceability of a satellite-based imager can be used to calibrate a radiometer despite differences in spectral channel sensitivities. This calibration transfer shows agreement within the uncertainty of both the various instruments for most spectral channels.

  3. Extreme Ultraviolet Variability Experiment (EVE) Multiple EUV Grating Spectrographs (MEGS): Radiometric Calibrations and Results

    Science.gov (United States)

    Hock, R. A.; Chamberlin, P. C.; Woods, T. N.; Crotser, D.; Eparvier, F. G.; Woodraska, D. L.; Woods, E. C.

    2012-01-01

    The NASA Solar Dynamics Observatory (SDO), scheduled for launch in early 2010, incorporates a suite of instruments including the Extreme Ultraviolet Variability Experiment (EVE). EVE has multiple instruments including the Multiple Extreme ultraviolet Grating Spectrographs (MEGS) A, B, and P instruments, the Solar Aspect Monitor (SAM), and the Extreme ultraviolet SpectroPhotometer (ESP). The radiometric calibration of EVE, necessary to convert the instrument counts to physical units, was performed at the National Institute of Standards and Technology (NIST) Synchrotron Ultraviolet Radiation Facility (SURF III) located in Gaithersburg, Maryland. This paper presents the results and derived accuracy of this radiometric calibration for the MEGS A, B, P, and SAM instruments, while the calibration of the ESP instrument is addressed by Didkovsky et al. ( Solar Phys., 2010, doi:10.1007/s11207-009-9485-8). In addition, solar measurements that were taken on 14 April 2008, during the NASA 36.240 sounding-rocket flight, are shown for the prototype EVE instruments.

  4. Analysis of aerosol properties derived from sun photometer and lidar over Dunhuang radiometric calibration site

    Science.gov (United States)

    Chen, Lin; Jing, Yingying; Zhang, Peng; Hu, Xiuqing

    2016-05-01

    Duhuang site has been selected as China Radiation Calibration Site (CRCS) for Remote Sensing Satellite Sensors since 1996. With the economic development of Dunhuang city, the ambient of the radiation calibration field has changed in recent years. Taking into account the key role of aerosol in radiometric calibration, it is essential to investigate the aerosol optical properties over Dunhuang radiometric calibration site. In this paper, the CIMEL sun photometer (CE-318) and Mie-scattering Lidar are simultaneously used to measure aerosol optical properties in Dunhuang site. Data from aerosol-bands of sun photometer are used in a Langley method to determine spectral optical depths of aerosol. And Lidar is utilized to obtain information of vertical profile and integrated aerosol optical depths at different heights. The results showed that the aerosol optical depth at 500 nm wavelength during the in-situ measurement campaigns varied from 0.1 to 0.3 in Dunhuang site. And the observation results also indicated that high aerosol concentration layer mostly located at the height of about 2~4 km. These results implies that the aerosol concentration of atmosphere in Dunhuang was relatively small and suitable for in-flight calibration for remote sensing satellite sensors.

  5. OCRA radiometric cloud fractions for GOME-2 on MetOp-A/B

    Directory of Open Access Journals (Sweden)

    R. Lutz

    2015-12-01

    Full Text Available This paper describes an approach for cloud parameter retrieval (radiometric cloud fraction estimation using the polarization measurements of the Global Ozone Monitoring Experiment-2 (GOME-2 on-board the MetOp-A/B satellites. The core component of the Optical Cloud Recognition Algorithm (OCRA is the calculation of monthly cloud-free reflectances for a global grid (resolution of 0.2° in longitude and 0.2° in latitude and to derive radiometric cloud fractions. These cloud fractions will serve as a priori information for the retrieval of cloud top height (CTH, cloud top pressure (CTP, cloud top albedo (CTA and cloud optical thickness (COT with the Retrieval Of Cloud Information using Neural Networks (ROCINN algorithm. This approach is already being implemented operationally for the GOME/ERS-2 and SCIAMACHY/ENVISAT sensors and here we present version 3.0 of the OCRA algorithm applied to the GOME-2 sensors. Based on more than six years of GOME-2A data (February 2007–June 2013, reflectances are calculated for ≈ 35 000 orbits. For each measurement a degradation correction as well as a viewing angle dependent and latitude dependent correction is applied. In addition, an empirical correction scheme is introduced in order to remove the effect of oceanic sun glint. A comparison of the GOME-2A/B OCRA cloud fractions with co-located AVHRR geometrical cloud fractions shows a general good agreement with a mean difference of −0.15±0.20. From operational point of view, an advantage of the OCRA algorithm is its extremely fast computational time and its straightforward transferability to similar sensors like OMI (Ozone Monitoring Instrument, TROPOMI (TROPOspheric Monitoring Instrument on Sentinel 5 Precursor, as well as Sentinel 4 and Sentinel 5. In conclusion, it is shown that a robust, accurate and fast radiometric cloud fraction estimation for GOME-2 can be achieved with OCRA by using the polarization measurement devices (PMDs.

  6. OCRA radiometric cloud fractions for GOME-2 on MetOp-A/B

    Science.gov (United States)

    Lutz, Ronny; Loyola, Diego; Gimeno García, Sebastián; Romahn, Fabian

    2016-05-01

    This paper describes an approach for cloud parameter retrieval (radiometric cloud-fraction estimation) using the polarization measurements of the Global Ozone Monitoring Experiment-2 (GOME-2) onboard the MetOp-A/B satellites. The core component of the Optical Cloud Recognition Algorithm (OCRA) is the calculation of monthly cloud-free reflectances for a global grid (resolution of 0.2° in longitude and 0.2° in latitude) to derive radiometric cloud fractions. These cloud fractions will serve as a priori information for the retrieval of cloud-top height (CTH), cloud-top pressure (CTP), cloud-top albedo (CTA) and cloud optical thickness (COT) with the Retrieval Of Cloud Information using Neural Networks (ROCINN) algorithm. This approach is already being implemented operationally for the GOME/ERS-2 and SCIAMACHY/ENVISAT sensors and here we present version 3.0 of the OCRA algorithm applied to the GOME-2 sensors. Based on more than five years of GOME-2A data (April 2008 to June 2013), reflectances are calculated for ≈ 35 000 orbits. For each measurement a degradation correction as well as a viewing-angle-dependent and latitude-dependent correction is applied. In addition, an empirical correction scheme is introduced in order to remove the effect of oceanic sun glint. A comparison of the GOME-2A/B OCRA cloud fractions with colocated AVHRR (Advanced Very High Resolution Radiometer) geometrical cloud fractions shows a general good agreement with a mean difference of -0.15 ± 0.20. From an operational point of view, an advantage of the OCRA algorithm is its very fast computational time and its straightforward transferability to similar sensors like OMI (Ozone Monitoring Instrument), TROPOMI (TROPOspheric Monitoring Instrument) on Sentinel 5 Precursor, as well as Sentinel 4 and Sentinel 5. In conclusion, it is shown that a robust, accurate and fast radiometric cloud-fraction estimation for GOME-2 can be achieved with OCRA using polarization measurement devices (PMDs).

  7. Local-scale flood mapping on vegetated floodplains from radiometrically calibrated airborne LiDAR data

    Science.gov (United States)

    Malinowski, Radosław; Höfle, Bernhard; Koenig, Kristina; Groom, Geoff; Schwanghart, Wolfgang; Heckrath, Goswin

    2016-09-01

    Knowledge about the magnitude of localised flooding of riverine areas is crucial for appropriate land management and administration at regional and local levels. However, detection and delineation of localised flooding with remote sensing techniques are often hampered on floodplains by the presence of herbaceous vegetation. To address this problem, this study presents the application of full-waveform airborne laser scanning (ALS) data for detection of floodwater extent. In general, water surfaces are characterised by low values of backscattered energy due to water absorption of the infrared laser shots, but the exact strength of the recorded laser pulse depends on the area covered by the targets located within a laser pulse footprint area. To account for this we analysed the physical quantity of radiometrically calibrated ALS data, the backscattering coefficient, in relation to water and vegetation coverage within a single laser footprint. The results showed that the backscatter was negatively correlated to water coverage, and that of the three distinguished classes of water coverage (low, medium, and high) only the class with the largest extent of water cover (>70%) had relatively distinct characteristics that can be used for classification of water surfaces. Following the laser footprint analysis, three classifiers, namely AdaBoost with Decision Tree, Naïve Bayes and Random Forest, were utilised to classify laser points into flooded and non-flooded classes and to derive the map of flooding extent. The performance of the classifiers is highly dependent on the set of laser points features used. Best performance was achieved by combining radiometric and geometric laser point features. The accuracy of flooding maps based solely on radiometric features resulted in overall accuracies of up to 70% and was limited due to the overlap of the backscattering coefficient values between water and other land cover classes. Our point-based classification methods assure a high

  8. Optical detectors for integration into a low cost radiometric device for in-water applications: A feasibility study

    CSIR Research Space (South Africa)

    Ramkilowan, A

    2013-04-01

    Full Text Available -based remote sensing techniques, coupled with in-situ radiometric technology to offer a powerful and potentially cost effective method of addressing algal bloom related hazards. The work presented in this paper focuses on the decision making processes involved...

  9. Radiometric Measurements on Ag/n-Si Composite Films for Detecting Radiation in the Earth’s Atmospheric Windows

    Science.gov (United States)

    2009-02-20

    NAME(S) AND ADDRESS(ES) AFOSR/NE 875 N. Randolph Street Suite 324, room 3112 Arlington VA 22203-1768 Dr. Silversmith 10. SPONSOR/MONITOR’S...008 to 30-11-008 AFOSR Grant # FA9550-08-1-0008 Program Manager - Dr. Donald Silversmith Radiometric Measurements on Ag/n-Si Composite Films for

  10. The Relationship between Balancing Reactions and Reaction Lifetimes: A Consideration of the Potassium-Argon Radiometric Method for Dating Minerals

    Science.gov (United States)

    Howard, William A.

    2005-01-01

    A detailed examination of a commonly accepted practice in geology offers an example of how to stimulate critical thinking, teaches students how to read reactions, and challenges students to formulate better experiments for determining mineral ages more accurately. A demonstration of a Potassium-Argon radiometric method for dating minerals is…

  11. Application of a radiometric method for evaluation of loss of salicylic acid during isolation from biologic material.

    Science.gov (United States)

    Ostrowski, A

    1983-01-01

    A radiometric method for evaluation of loss of salicylic acid in the process of isolation from biologic material is described. According to this study the mean loss during the total process of isolation amounts to 33.59%, the specific values being 19.47% during protein precipitation, 10.68% during extraction, and 3.44% during evaporation of solvent.

  12. Pilot study of the application of Tellus airborne radiometric and soil geochemical data for radon mapping.

    Science.gov (United States)

    Appleton, J D; Miles, J C H; Green, B M R; Larmour, R

    2008-10-01

    The scope for using Tellus Project airborne gamma-ray spectrometer and soil geochemical data to predict the probability of houses in Northern Ireland having high indoor radon concentrations is evaluated, in a pilot study in the southeast of the province, by comparing these data statistically with in-house radon measurements. There is generally good agreement between radon maps modelled from the airborne radiometric and soil geochemical data using multivariate linear regression analysis and conventional radon maps which depend solely on geological and indoor radon data. The radon maps based on the Tellus Project data identify some additional areas where the radon risk appears to be relatively high compared with the conventional radon maps. One of the ways of validating radon maps modelled on the Tellus Project data will be to carry out additional indoor measurements in these areas.

  13. Experimental results and simulations from aperture synthesis three-dimensional radiometric imaging

    Science.gov (United States)

    Salmon, Neil A.

    2016-10-01

    This paper presents the theory and algorithm of how a three-dimensional (3D) image can be generated using crosscorrelations of radiometric emission from a source measured using antennas in the near field. An example of how the algorithm is used to create 3D images of emission measured from a noise source is presented, indicating the presence of Fresnel noise and aliasing in the experimental data when the source is moved away from the phase centre. Simulations are presented which reproduce the Fresnel noise as generated by a 3x3x3 array of point sources located at the centre of a 2 metre diameter array of antennas representing a security screening portal. Two methods of reducing the Fresnel noise are presented: 1) a software method which makes successive more accurate estimates of the locations and intensities of sources; 2) a hardware method which reduces the coherence length of the radiation by increasing the radiation bandwidth.

  14. A Radiometric All-Sky Infrared Camera (RASICAM) for DES/CTIO

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, Peter M.; Rogers, Howard; Schindler, Rafe H.; /SLAC

    2010-08-25

    A novel radiometric all-sky infrared camera [RASICAM] has been constructed to allow automated real-time quantitative assessment of night sky conditions for the Dark Energy Camera [DECam] located on the Blanco Telescope at the Cerro Tololo Inter-American Observatory in Chile. The camera is optimized to detect the position, motion and optical depth of thin, high (8-10km) cirrus clouds and contrails by measuring their apparent temperature above the night sky background. The camera system utilizes a novel wide-field equiresolution catadioptic mirror system that provides sky coverage of 2{pi} azimuth and 14-90{sup o} from zenith. Several new technological and design innovations allow the RASICAM system to provide unprecedented cloud detection and IR-based photometricity quantification. The design of the RASICAM system is presented.

  15. A HISTORICAL OUTLINE OF RADIONUCLIDE CONTAMINATION OF THE YENISEY FLOODPLAIN BASED ON LANDSCAPE AND RADIOMETRIC SURVEY

    Directory of Open Access Journals (Sweden)

    Vitaly Linnik

    2013-01-01

    Full Text Available Distribution of technogenic radionuclides discharged by the Krasnoyarsk Mining and Chemical Combine (KMCC, Zheleznogorsk in the period from 1958 to 1992 has been studied in floodplain landscapes of the Yenisey river. After shutting down the direct-flow reactors the radioactive contamination of the Yenisey river became dozen times lower. Performed landscape and radiometric studies revealed factors responsible for radionuclide differentiation and the character of radionuclide distribution within two landscape segments of the Yenisey river floodplain. The first segment characterized the impact zone from 16 km to 20 downstream the discharge, the second one was studied in the remote zone as far as 2000 km down the river. Artificial radionuclide contamination was most intensive in the 60-ies of the past century when it reached the Kara Sea. Traces of that contamination were registered in soils of both sites at the depth of 20–50 cm.

  16. Age and duration of the Deccan Traps, India: A review of radiometric and paleomagnetic constraints

    Indian Academy of Sciences (India)

    Kanchan Pande

    2002-06-01

    A review of the available radiometric and paleomagnetic data from the Deccan Flood Basalt Province (DFBP) suggests that the volcanism was episodic in nature and probably continued over an extended duration from 69Ma to 63Ma between 31R and 28N. It is likely that the most intense pulse of volcanism at 66.9 ± 0.2Ma preceded the Cretaceous Tertiary Boundary (KTB, 65.2 ± 0.2Ma) events by ∼1.7Ma. The magnetostratigraphic record in the Deccan lava pile is incomplete and it is therefore possible that the lava ows constituting the reverse polarity sequence were erupted in more than one reversed magnetic chron.

  17. SPECTRAL REFLECTANCE MEASUREMENTS AT THE CHINA RADIOMETRIC CALIBRATION TEST SITE FOR THE REMOTE SENSING SATELITE SENSOR

    Institute of Scientific and Technical Information of China (English)

    张玉香; 张广顺; 刘志权; 张立军; 朱顺斌; 戎志国; 邱康睦

    2001-01-01

    A comprehensive field experiment was made with the support of the project of China Radiometric Calibration Site (CRCS) during June-July 1999. Ground reflectance spectra were measured at Dunhuang Calibration Test Site in the experiment. More than two thousands of spectral curves were acquired in a 20 km × 20 km area. The spectral coverage is from 350 nm to 2500 nm. The measurement values show that reflectance is between 10% and 33% at the VISSWIR spectral region. The standard deviation of reflectance is between 1.0% and 2.0% for the spectral range. Optical characteristics and ground reflectance measurements at the Dunhuang test site, result analysis and error source were described. In addition, a comparison of the reflectance obtained in 1999 with those measured in 1994 and 1996 was also made.

  18. Pre-Launch Radiometric Characterization of JPSS-1 VIIRS Thermal Emissive Bands

    Directory of Open Access Journals (Sweden)

    Jeff McIntire

    2016-01-01

    Full Text Available Pre-launch characterization and calibration of the thermal emissive spectral bands on the Joint Polar Satellite System (JPSS-1 Visible Infrared Imaging Radiometer Suite (VIIRS is critical to ensure high quality data products for environmental and climate data records post-launch. A comprehensive test program was conducted at the Raytheon El Segundo facility in 2013–2014, including extensive environmental testing. This work is focused on the thermal band radiometric performance and stability, including evaluation of a number of sensor performance metrics and estimation of uncertainties. Analysis has shown that JPSS-1 VIIRS thermal bands perform very well in relation to their design specifications, and comparisons to the Suomi National Polar-orbiting Partnership (SNPP VIIRS instrument have shown their performance to be comparable.

  19. Radiometric quality of the MODIS bands at 667 and 678nm

    Science.gov (United States)

    Meister, Gerhard; Franz, Bryan A.

    2011-10-01

    The MODIS instruments on Terra and Aqua were designed to allow the measurement of chlorophyll fluorescence effects over ocean. The retrieval algorithm is based on the difference between the water-leaving radiances at 667nm and 678nm. The water-leaving radiances at these wavelengths are usually very low relative to the topof- atmosphere radiances. The high radiometric accuracy needed to retrieve the small fluorescence signal lead to a dual gain design for the 667 and 678nm bands. This paper discusses the benefits obtained from this design choice and provides justification for the use of only one set of gains for global processing of ocean color products. Noise characteristics of the two bands and their related products are compared to other products of bands from 412nm to 2130nm. The impact of polarization on the two bands is discussed. In addition, the impact of stray light on the two bands is compared to other MODIS bands.

  20. DEM-Based SAR Pixel Area Estimation For Enhanced Geocoding Refinement And Radiometric Normalization

    Science.gov (United States)

    Frey, Othmar; Santoro, Maurizio; Werner, Charles L.; Wegmuller, Urs

    2012-01-01

    Precise terrain-corrected georeferencing of SAR images and derived products in range-Doppler coordinates is important with respect to several aspects, such as data interpretation, combination with other geodata products, and transformation of, e.g., terrain heights into SAR geometry as used in DInSAR applications. For georeferencing a look-up table is calculated and refined based on a coregistration of the actual SAR image to a simulated SAR image. The impact of using two different implementations of such a simulator of topography-induced radar brightness, an approach based on angular relationships and a pixel-area based method are discussed in this paper. It is found that the pixel-area-based method leads to considerable improvements with regard to the robustness of georeferencing and also with regard to radiometric normalization in layover- affected areas.

  1. Time course of radiometric detection of positive blood cultures in childhood

    Energy Technology Data Exchange (ETDEWEB)

    Meadow, W.L.; Schwartz, I.K.

    1986-05-01

    We have determined the time course of radiometric detection of microbial growth in 2348 positive blood culture specimens obtained at Wyler Children's Hospital during a 5-year interval. Overall 72 and 88% of isolates were detected within 48 and 72 hours after sampling, respectively. For pathogenic organisms aerobic detection was generally more rapid and more inclusive than anaerobic detection. At 48 hours of incubation the detection of six potential pathogens (Salmonella sp., Haemophilus influenzae, Group D streptococci, Neisseria meningitidis, coagulase-negative staphylococci, Candida sp.) was significantly delayed compared with detection of other pathogenic organisms recovered from blood. At 72 hours of incubation the detection rates remained less than 95% for H. influenzae, Staphylococcus aureus, Klebsiella sp., coagulase-negative staphylococci, Group D streptococci and Candida sp. These data should assist clinical decisions regarding duration of antibiotic therapy for the presumptive diagnosis of bacteremia in children.

  2. Laboratory experience with radiometric detection of bacteremia with three culture media

    Energy Technology Data Exchange (ETDEWEB)

    Wicher, K.; Koscinski, D.

    1984-10-01

    In two long-term studies, the BACTEC radiometric system for detection of bacteremia was evaluated with three culture media each: (i) BACTEC media 6A (for aerobes) and 7B (for anaerobes) plus a thioglycolate medium and (ii) BACTEC media 6A, 7B, and 8A (hypertonic). In study 1, clinically significant isolates were identified in 1,873 (13.9%) of 13,432 blood cultures with all three media. The thioglycolate medium revealed 143 (1.1%) organisms not recovered from the 6A and 7B media. In study 2, isolates were identified in 1,135 (12.9%) of 8,759 cultures with all three media; 104 (1.2%) organisms were isolated only from the hypertonic medium. The increased yield of positive cultures in the three-medium system is likely due to the larger volume of blood cultured.

  3. Electronic transport characterization of silicon wafers by spatially resolved steady-state photocarrier radiometric imaging

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Qian [Institute of Optics and Electronics, Chinese Academy of Sciences, P. O. Box 350, Shuangliu, Chengdu 610209 (China); University of the Chinese Academy of Sciences, Beijing 100039 (China); Li, Bincheng, E-mail: bcli@ioe.ac.cn [Institute of Optics and Electronics, Chinese Academy of Sciences, P. O. Box 350, Shuangliu, Chengdu 610209 (China); School of Optoelectronic Information, University of Electronic Science and Technology of China, Chengdu 610054 (China)

    2015-09-28

    Spatially resolved steady-state photocarrier radiometric (PCR) imaging technique is developed to characterize the electronic transport properties of silicon wafers. Based on a nonlinear PCR theory, simulations are performed to investigate the effects of electronic transport parameters (the carrier lifetime, the carrier diffusion coefficient, and the front surface recombination velocity) on the steady-state PCR intensity profiles. The electronic transport parameters of an n-type silicon wafer are simultaneously determined by fitting the measured steady-state PCR intensity profiles to the three-dimensional nonlinear PCR model. The determined transport parameters are in good agreement with the results obtained by the conventional modulated PCR technique with multiple pump beam radii.

  4. Importance of radiometric survey in radiodiagnosis installationscalculated; Importancia del levantamiento radiometrico en instalaciones de radiodiagnostico

    Energy Technology Data Exchange (ETDEWEB)

    Leyton, Fernando; Alarcon, Luis; Zapata, Victor H.; Ortega, Dulia; Ramirez, Alfredo; Aravena, Gonzalo [Hospital Clinico Universidad de Chile, Santiago (Chile); Ubeda, Carlos [Universidad de Tarapaca, Arica (Chile); Oyarzun, Carlos [Comision Chilena de Energia Nuclear (CCHEN), Santiago (Chile); Inzulza, Alonso [Hospital Juan Noe (Chile)

    2005-07-01

    A radiometric survey was conducted in two services of imaging with a total of 7 evaluated radiology rooms. The Quality Control Protocol methodology was used in Radiology ARCAL (Regional Agreement of cooperation for the promotion of nuclear science and technology in Latin America and the Caribbean) XLIX of the International Atomic Energy Agency (IAEA). The effective dose in different positions of interest rates were calculated, from the point of view of radiation protection. All evaluated rooms have rates of effective doses that meet the values limits set in the Protocol ARCAL XLIX, for 82% of the positions evaluated. However operators located in the position A (controlled area) exceed on average 370% with a range of [1-870] the limit proposed by ARCAL XLIX.

  5. Determination of plutonium isotopes (238Pu, 239Pu, 240Pu, 241Pu) in environmental samples using radiochemical separation combined with radiometric and mass spectrometric measurements.

    Science.gov (United States)

    Xu, Yihong; Qiao, Jixin; Hou, Xiaolin; Pan, Shaoming; Roos, Per

    2014-02-01

    This paper reports an analytical method for the determination of plutonium isotopes ((238)Pu, (239)Pu, (240)Pu, (241)Pu) in environmental samples using anion exchange chromatography in combination with extraction chromatography for chemical separation of Pu. Both radiometric methods (liquid scintillation counting and alpha spectrometry) and inductively coupled plasma mass spectrometry (ICP-MS) were applied for the measurement of plutonium isotopes. The decontamination factors for uranium were significantly improved up to 7.5 × 10(5) for 20 g soil compared to the level reported in the literature, this is critical for the measurement of plutonium isotopes using mass spectrometric technique. Although the chemical yield of Pu in the entire procedure is about 55%, the analytical results of IAEA soil 6 and IAEA-367 in this work are in a good agreement with the values reported in the literature or reference values, revealing that the developed method for plutonium determination in environmental samples is reliable. The measurement results of (239+240)Pu by alpha spectrometry agreed very well with the sum of (239)Pu and (240)Pu measured by ICP-MS. ICP-MS can not only measure (239)Pu and (240)Pu separately but also (241)Pu. However, it is impossible to measure (238)Pu using ICP-MS in environmental samples even a decontamination factor as high as 10(6) for uranium was obtained by chemical separation.

  6. Forest Vertical Parameter Estimation Using PolInSAR Imagery Based on Radiometric Correction

    Directory of Open Access Journals (Sweden)

    Yu Zhang

    2016-10-01

    Full Text Available This work introduces an innovative radiometric terrain correction algorithm using PolInSAR imagery for improving forest vertical structure parameter estimation. The variance of radar backscattering caused by terrain undulation has been considered in this research by exploiting an iteration optimization procedure to improve the backscattering estimation for a Synthetic Aperture Radar (SAR image. To eliminate the variance of backscatter coefficients caused by the local incident angle, a radiometric normalization algorithm has been investigated to compensate the influence of terrain on backscattering values, which hinders forest vertical parameter estimation. In vertical parameter estimation, species diversity and the spatial distribution of different vegetation have been modeled. Then, a combination of Fisher’s Alpha-Diversity model parameter estimation and the three-stage inversion method was designed for the vertical structure parameter. To demonstrate the efficiency of the proposed method in forest height estimation, the classical phase difference and three-stage inversion approach have been performed for the purpose of comparison. The proposed algorithm is tested on ALOS PALSAR (Advanced Land Observing Satellite Phased Array type L-band Synthetic Aperture Radar and RADARSAT-2 (Radio Direction and Range Satellite 2 data sets for the Great Xing’an Mountain area and BioSAR (Biomass Synthetic Aperture Radar 2007 data sets for the Remningstorp area. Height estimation results have also been validated using in-situ measurements. Experiments indicate the proposed method has the ability to compensate the influence of terrain undulation and improving the accuracy of forest vertical structure parameter estimation.

  7. Radiometric, geometric, and image quality assessment of ALOS AVNIR-2 and PRISM sensors

    Science.gov (United States)

    Saunier, S.; Goryl, P.; Chander, G.; Santer, R.; Bouvet, M.; Collet, B.; Mambimba, A.; Kocaman, Aksakal S.

    2010-01-01

    The Advanced Land Observing Satellite (ALOS) was launched on January 24, 2006, by a Japan Aerospace Exploration Agency (JAXA) H-IIA launcher. It carries three remote-sensing sensors: 1) the Advanced Visible and Near-Infrared Radiometer type 2 (AVNIR-2); 2) the Panchromatic Remote-Sensing Instrument for Stereo Mapping (PRISM); and 3) the Phased-Array type L-band Synthetic Aperture Radar (PALSAR). Within the framework of ALOS Data European Node, as part of the European Space Agency (ESA), the European Space Research Institute worked alongside JAXA to provide contributions to the ALOS commissioning phase plan. This paper summarizes the strategy that was adopted by ESA to define and implement a data verification plan for missions operated by external agencies; these missions are classified by the ESA as third-party missions. The ESA was supported in the design and execution of this plan by GAEL Consultant. The verification of ALOS optical data from PRISM and AVNIR-2 sensors was initiated 4 months after satellite launch, and a team of principal investigators assembled to provide technical expertise. This paper includes a description of the verification plan and summarizes the methodologies that were used for radiometric, geometric, and image quality assessment. The successful completion of the commissioning phase has led to the sensors being declared fit for operations. The consolidated measurements indicate that the radiometric calibration of the AVNIR-2 sensor is stable and agrees with the Landsat-7 Enhanced Thematic Mapper Plus and the Envisat MEdium-Resolution Imaging Spectrometer calibration. The geometrical accuracy of PRISM and AVNIR-2 products improved significantly and remains under control. The PRISM modulation transfer function is monitored for improved characterization. ?? 2006 IEEE.

  8. Accelerator physics and radiometric properties of superconducting wavelength shifters; Beschleunigerphysik und radiometrische Eigenschaften supraleitender Wellenlaengenschieber

    Energy Technology Data Exchange (ETDEWEB)

    Scheer, Michael

    2008-11-17

    Subject of this thesis is the operation of wave-length shifters at electron storage rings and their use in radiometry. The basic aspects of the radiometry, the technical requirements, the influence of wave-length shifters on the storage ring, and results of first measurements are presented for a device installed at BESSY. Most of the calculations are carried out by the program WAVE, which has been developed within this thesis. WAVE allows to calculate the synchrotron radiation spectra of wavelength shifters within an relative uncertainty of 1/100000. The properties of wave-length shifters in terms of accelerator physics as well as a generating function for symplectic tracking calculations can also be calculated by WAVE. The later was implemented in the tracking code BETA to investigate the influence of insertion devices on the dynamic aperture and emittance of the storage ring. These studies led to the concept of alternating low- and high-beta-sections at BESSY-II, which allow to operate superconducting insertion devices without a significant distortion of the magnetic optics. To investigate the experimental aspects of the radiometry at wave-length shifters, a program based on the Monte-Carlo-code GEANT4 has been developed. It allows to simulate the radiometrical measurements and the absorption properties of detectors. With the developed codes first radiometrical measurements by the PTB have been analysed. A comparison of measurements and calculations show a reasonable agreement with deviations of about five percent in the spectral range of 40-60 keV behind a 1-mm-Cu filter. A better agreement was found between 20 keV and 80 keV without Cu filter. In this case the measured data agreed within a systematic uncertainty of two percent with the results of the calculations. (orig.)

  9. RLS Instrument Radiometric Model: Instrument performance theoretical evaluation and experimental checks

    Science.gov (United States)

    Quintana, César; Ramos, Gonzalo; Moral, Andoni; Rodriguez, Jose Antonio; Pérez, Carlos; Hutchinson, Ian; INGLEY, Richard; Rull, Fernando

    2016-10-01

    Raman Laser Spectrometer (RLS) is one of the Pasteur payload instruments located at the Rover of the ExoMars mission and within the ESA's Aurora Exploration Programme. RLS will explore the Mars surface composition through the Raman spectroscopy technique. The instrument is divided into several units: a laser for Raman emission stimulation, an internal optical head (iOH) for sample excitation and for Raman emission recovering, a spectrometer with a CCD located at its output (SPU), the optical harness (OH) for the units connection, from the laser to the excitation path of the iOH and from the iOH reception path to the spectrometer, and the corresponding electronics for the CCD operation.Due to the variability of the samples to be analyzed on Mars, a radiometry prediction for the instrument performance results to be of the critical importance. In such a framework, and taking into account the SNR (signal to noise ratio) required for the achievement of successful results from the scientific point of view (a proper information about the Mars surface composition), a radiometric model has been developed to provide the requirements for the different units, i.e. the laser irradiance, the iOH, OH, and SPU throughputs, and the samples that will be possible to be analyzed in terms of its Raman emission and the relationship of the Raman signal with respect to fluorescence emission, among others.The radiometric model fundamentals (calculations and approximations), as well as the first results obtained during the bread board characterization campaign are here reported on.

  10. Assessment of the Short-Term Radiometric Stability between Terra MODIS and Landsat 7 ETM+ Sensors

    Science.gov (United States)

    Choi, Taeyoung; Xiong, Xiaxiong; Chander, G.; Angal, Amit

    2009-01-01

    The Landsat 7 (L7) Enhanced Thematic Mapper (ETM+) sensor was launched on April 15th, 1999 and has been in operation for over nine years. It has six reflective solar spectral bands located in the visible and shortwave infrared part of the electromagnetic spectrum (0.5 - 2.5 micron) at a spatial resolution of 30 m. The on-board calibrators are used to monitor the on-orbit sensor system changes. The ETM+ performs solar calibrations using on-board Full Aperture Solar Calibrator (FASC) and the Partial Aperture Solar Calibrator (PASC). The Internal Calibrator Lamp (IC) lamps, a blackbody and shutter optics constitute the on-orbit calibration mechanism for ETM+. On 31 May 2003, a malfunction of the scan-line corrector (SLC) mirror assembly resulted in the loss of approximately 22% of the normal scene area. The missing data affects most of the image with scan gaps varying in width from one pixel or less near the centre of the image to 14 pixels along the east and west edges of the image, creating a wedge-shaped pattern. However, the SLC failure has no impacts on the radiometric performance of the valid pixels. On December 18, 1999, the Moderate Resolution Imaging Spectroradiometer (MODIS) Proto-Flight Model (PFM) was launched on-board the NASA's EOS Terra spacecraft. Terra MODIS has 36 spectral bands with wavelengths ranging from 0.41 to 14.5 micron and collects data over a wide field of view angle (+/-55 deg) at three nadir spatial resolutions of 250 m, 500 in 1 km for bands 1 to 2, 3 to 7, and 8 to 36, respectively. It has 20 reflective solar bands (RSB) with spectral wavelengths from 0.41 to 2.1 micron. The RSB radiometric calibration is performed by using on-board solar diffuser (SD), solar diffuser stability monitor (SDSM), space-view (SV), and spectro-radiometric calibration assembly (SRCA). Through the SV port, periodic lunar observations are used to track radiometric response changes at different angles of incidence (AOI) of the scan mirror. As a part of the AM

  11. Digital Airborne Photogrammetry—A New Tool for Quantitative Remote Sensing?—A State-of-the-Art Review On Radiometric Aspects of Digital Photogrammetric Images

    Directory of Open Access Journals (Sweden)

    Nikolaj Veje

    2009-09-01

    Full Text Available The transition from film imaging to digital imaging in photogrammetric data capture is opening interesting possibilities for photogrammetric processes. A great advantage of digital sensors is their radiometric potential. This article presents a state-of-the-art review on the radiometric aspects of digital photogrammetric images. The analysis is based on a literature research and a questionnaire submitted to various interest groups related to the photogrammetric process. An important contribution to this paper is a characterization of the photogrammetric image acquisition and image product generation systems. The questionnaire revealed many weaknesses in current processes, but the future prospects of radiometrically quantitative photogrammetry are promising.

  12. CO₂ laser welding of corneal cuts with albumin solder using radiometric temperature control.

    Science.gov (United States)

    Strassmann, Eyal; Livny, Eitan; Loya, Nino; Kariv, Noam; Ravid, Avi; Katzir, Abraham; Gaton, Dan D

    2013-01-01

    To examine the efficacy and reproducibility of CO₂ laser soldering of corneal cuts using real-time infrared fiber-optic radiometric control of tissue temperature in bovine eyes (in vitro) and to evaluate the duration of this procedure in rabbit eyes (in vivo). In vitro experiment: a 6-mm central perforating cut was induced in 40 fresh bovine eyes and sealed with a CO₂ laser, with or without albumin soldering, following placement of a single approximating nylon suture. A fiber-optic radiometric temperature control system for the CO₂ laser was used. Leaking pressure and histological findings were analyzed and compared between groups. In vivo experiment: following creation of a central perforation, 6 rabbit eyes were treated with a CO₂ laser with albumin solder and 6 rabbit eyes were treated with 10-0 nylon sutures. The amount of time needed for completion of the procedures was compared. In vitro experiment: effective sealing was achieved by CO₂ laser soldering. Mean (± SD) leaking pressure was 109 ± 30 mm Hg in the bovine corneas treated by the laser with albumin solder compared to 51 ± 7 mm Hg in the sutured control eyes (n = 10 each; p laser without albumin solder (48 ± 12 mm Hg) and in the cuts sealed only with albumin without laser welding (6.3 ± 4 mm Hg) than in the cuts treated with laser welding and albumin solder. In vivo experiment: mean surgical time was 140 ± 17 s in the laser-treated rabbits compared to 330 ± 30 s in the sutured controls (n = 6; p laser soldering revealed sealed corneal edges with a small gap bridged by coagulated albumin. The inflammatory reaction was minimal in contrast to the sutured controls. No thermal damage was detected at the wound edges. CO₂ laser soldering combined with the fiber-optic radiometer is an effective, reliable, and rapid tool for the closure of corneal wounds, and holds advantages over conventional suturing in terms of leaking pressure and surgical time. Copyright © 2013 S. Karger AG, Basel.

  13. Making SAR Data Accessible - ASF's ALOS PALSAR Radiometric Terrain Correction Project

    Science.gov (United States)

    Meyer, F. J.; Arko, S. A.; Gens, R.

    2015-12-01

    While SAR data have proven valuable for a wide range of geophysical research questions, so far, largely only the SAR-educated science communities have been able to fully exploit the information content of internationally available SAR archives. The main issues that have been preventing a more widespread utilization of SAR are related to (1) the diversity and complexity of SAR data formats, (2) the complexity of the processing flows needed to extract geophysical information from SAR, (3) the lack of standardization and automation of these processing flows, and (4) the often ignored geocoding procedures, leaving the data in image coordinate space. In order to improve upon this situation, ASF's radiometric terrain-correction (RTC) project is generating uniformly formatted and easily accessible value-added products from the ASF Distributed Active Archive Center's (DAAC) five-year archive of JAXA's ALOS PALSAR sensor. Specifically, the project applies geometric and radiometric corrections to SAR data to allow for an easy and direct combination of obliquely acquired SAR data with remote sensing imagery acquired in nadir observation geometries. Finally, the value-added data is provided to the user in the broadly accepted Geotiff format, in order to support the easy integration of SAR data into GIS environments. The goal of ASF's RTC project is to make SAR data more accessible and more attractive to the broader SAR applications community, especially to those users that currently have limited SAR expertise. Production of RTC products commenced October 2014 and will conclude late in 2015. As of July 2015, processing of 71% of ASF's ALOS PALSAR archive was completed. Adding to the utility of this dataset are recent changes to the data access policy that allow the full-resolution RTC products to be provided to the public, without restriction. In this paper we will introduce the processing flow that was developed for the RTC project and summarize the calibration and validation

  14. Gravity, magnetic, and radiometric data for Newberry Volcano, Oregon, and vicinity

    Science.gov (United States)

    Wynn, Jeff

    2014-01-01

    Newberry Volcano in central Oregon is a 3,100-square-kilometer (1,200-square-mile) shield-shaped composite volcano, occupying a location east of the main north-south trend of the High Cascades volcanoes and forming a transition between the High Lava Plains subprovince of the Basin and Range Province to the east and the Cascade Range to the west. Magnetic, gravity, and radiometric data have been gathered and assessed for the region around the volcano. These data have widely varying quality and resolution, even within a given dataset, and these limitations are evaluated and described in this release. Publicly available gravity data in general are too sparse to permit detailed modeling except along a few roads with high-density coverage. Likewise, magnetic data are also unsuitable for all but very local modeling, primarily because available data consist of a patchwork of datasets with widely varying line-spacing. Gravity data show only the broadest correlation with mapped geology, whereas magnetic data show moderate correlation with features only in the vicinity of Newberry Caldera. At large scales, magnetic data correlate poorly with both geologic mapping and gravity data. These poor correlations are largely due to the different sensing depths of the two potential fields methods, which respond to physical properties deeper than the surficial geology. Magnetic data derive from rocks no deeper than the Curie-point isotherm depth (10 to 15 kilometers, km, maximum), whereas gravity data reflect density-contrasts to 100 to 150 km depths. Radiometric data from the National Uranium Resource Evaluation (NURE) surveys of the 1980s have perhaps the coarsest line-spacing of all (as much as 10 km between lines) and are extremely “noisy” for several reasons inherent to this kind of data. Despite its shallow-sensing character, only a few larger anomalies in the NURE data correlate well with geologic mapping. The purpose of this data series release is to collect and place the

  15. Review of Terra MODIS thermal emissive band L1B radiometric performance

    Science.gov (United States)

    Moeller, Chris; Menzel, W. P.; Quinn, Greg

    2014-09-01

    The MODerate-resolution Imaging Spectroradiometer (MODIS) on NASA's Earth Observing System Terra satellite, launched into orbit on 18 December 1999, will have a "first light" 15th anniversary on 24 February 2015. For nearly 15 years the MODIS instrument has provided radiances in all spectral bands. Though some detectors have fallen below SNR thresholds, the vast majority of spectral bands continue to provide high quality L1B measurements for use in L2 science algorithms supporting global climate research. Radiometric accuracy of the Terra MODIS thermal emissive bands (TEBs) in the C6 L1B product has been assessed using various approaches over the nearly 15 year Terra MODIS data record, including comparisons with instruments on the ground, in aircraft under-flights, and on other satellites. All of these approaches contribute to the understanding of the Terra MODIS radiometric L1B performance. Early in the lifetime of Terra, ground-based measurements and NASA ER-2 aircraft under-flights revealed that TEBs in the infrared window ("window" bands) are well calibrated and performing within accuracy specifications. The ER-2 under-flights also suggested that many atmospheric bands may be performing outside of specification, especially LWIR CO2 sensitive bands that are subject to optical crosstalk, although analysis uncertainties are larger for atmospheric bands. Beginning in 2007, MetOp-A IASI observations were used to evaluate Terra MODIS TEB performance through Simultaneous Nadir Overpass (SNO) comparisons. These inter-satellite comparisons largely affirm the early aircraft and ground-based evaluations, showing that all Terra MODIS window bands have small biases, minimal trending, and minor detector and mirror side striping over the 2007-2013 timeframe. Most atmospheric bands are performing satisfactorily near to specification; however, biases, striping and trending are large and significantly out of specification in the water vapor sensitive band 27 and ozone sensitive

  16. Radiometric Cross-Calibration of the HJ-1B IRS in the Thermal Infrared Spectral Band

    Science.gov (United States)

    Sun, K.

    2012-12-01

    The natural calamities occur continually, environment pollution and destruction in a severe position on the earth presently, which restricts societal and economic development. The satellite remote sensing technology has an important effect on improving surveillance ability of environment pollution and natural calamities. The radiometric calibration is precondition of quantitative remote sensing; which accuracy decides quality of the retrieval parameters. Since the China Environment Satellite (HJ-1A/B) has been launched successfully on September 6th, 2008, it has made an important role in the economic development of China. The satellite has four infrared bands; and one of it is thermal infrared. With application fields of quantitative remote sensing in china, finding appropriate calibration method becomes more and more important. Many kinds of independent methods can be used to do the absolute radiometric calibration. In this paper, according to the characteristic of thermal infrared channel of HJ-1B thermal infrared multi-spectral camera, the thermal infrared spectral band of HJ-1B IRS was calibrated using cross-calibration methods based on MODIS data. Firstly, the corresponding bands of the two sensors were obtained. Secondly, the MONDTRAN was run to analyze the influences of different spectral response, satellite view zenith angle, atmosphere condition and temperature on the match factor. In the end, their band match factor was calculated in different temperature, considering the dissimilar band response of the match bands. Seven images of Lake Qinghai in different time were chosen as the calibration data. On the basis of radiance of MODIS and match factor, the IRS radiance was calculated. And then the calibration coefficients were obtained by linearly regressing the radiance and the DN value. We compared the result of this cross-calibration with that of the onboard blackbody calibration, which consistency was good.The maximum difference of brightness temperature

  17. Parallel algorithms of relative radiometric correction for images of TH-1 satellite

    Science.gov (United States)

    Wang, Xiang; Zhang, Tingtao; Cheng, Jiasheng; Yang, Tao

    2014-05-01

    The first generation of transitive stereo-metric satellites in China, TH-1 Satellite, is able to gain stereo images of three-line-array with resolution of 5 meters, multispectral images of 10 meters, and panchromatic high resolution images of 2 meters. The procedure between level 0 and level 1A of high resolution images is so called relative radiometric correction (RRC for short). The processing algorithm of high resolution images, with large volumes of data, is complicated and time consuming. In order to bring up the processing speed, people in industry commonly apply parallel processing techniques based on CPU or GPU. This article firstly introduces the whole process and each step of the algorithm - that is in application - of RRC for high resolution images in level 0; secondly, the theory and characteristics of MPI (Message Passing Interface) and OpenMP (Open Multi-Processing) parallel programming techniques is briefly described, as well as the superiority for parallel technique in image processing field; thirdly, aiming at each step of the algorithm in application and based on MPI+OpenMP hybrid paradigm, the parallelizability and the strategies of parallelism for three processing steps: Radiometric Correction, Splicing Pieces of TDICCD (Time Delay Integration Charge-Coupled Device) and Gray Level Adjustment among pieces of TDICCD are deeply discussed, and furthermore, deducts the theoretical acceleration rates of each step and the one of whole procedure, according to the processing styles and independence of calculation; for the step Splicing Pieces of TDICCD, two different strategies of parallelism are proposed, which are to be chosen with consideration of hardware capabilities; finally, series of experiments are carried out to verify the parallel algorithms by applying 2-meter panchromatic high resolution images of TH-1 Satellite, and the experimental results are analyzed. Strictly on the basis of former parallel algorithms, the programs in the experiments

  18. Market Liquidity and Funding Liquidity

    OpenAIRE

    Brunnermeier, Markus K; Lasse Heje Pedersen

    2007-01-01

    We provide a model that links an asset's market liquidity - i.e., the ease with which it is traded - and traders' funding liquidity - i.e., the ease with which they can obtain funding. Traders provide market liquidity, and their ability to do so depends on their availability of funding. Conversely, traders' funding, i.e., their capital and the margins they are charged, depend on the assets' market liquidity. We show that, under certain conditions, margins are destabilizing and market liquidit...

  19. Market Liquidity and Funding Liquidity

    OpenAIRE

    Markus K. Brunnermeier; Lasse Heje Pedersen

    2007-01-01

    We provide a model that links an asset's market liquidity - i.e., the ease with which it is traded - and traders' funding liquidity - i.e., the ease with which they can obtain funding. Traders provide market liquidity, and their ability to do so depends on their availability of funding. Conversely, traders' funding, i.e., their capital and the margins they are charged, depend on the assets' market liquidity. We show that, under certain conditions, margins are destabilizing and market liquidit...

  20. Experimental tests and radiometric calculations for the feasibility of fluorescence LIDAR-based discrimination of oil spills from UAV

    Science.gov (United States)

    Raimondi, Valentina; Palombi, Lorenzo; Lognoli, David; Masini, Andrea; Simeone, Emilio

    2017-09-01

    This paper presents experimental tests and radiometric calculations for the feasibility of an ultra-compact fluorescence LIDAR from an Unmanned Air Vehicle (UAV) for the characterisation of oil spills in natural waters. The first step of this study was to define the experimental conditions for a LIDAR and its budget constraints on the basis of the specifications of small UAVs already available on the market. The second step consisted of a set of fluorescence LIDAR measurements on oil spills in the laboratory in order to propose a simplified discrimination method and to calculate the oil fluorescence conversion efficiency. Lastly, the main technical specifications of the payload were defined and radiometric calculations carried out to evaluate the performances of both the payload and the proposed discrimination method.

  1. A definitive calibration record for the Landsat-5 thematic mapper anchored to the Landsat-7 radiometric scale

    Science.gov (United States)

    Teillet, P.M.; Helder, D.L.; Ruggles, T.A.; Landry, R.; Ahern, F.J.; Higgs, N.J.; Barsi, J.; Chander, G.; Markham, B.L.; Barker, J.L.; Thome, K.J.; Schott, J.R.; Palluconi, Frank Don

    2004-01-01

    A coordinated effort on the part of several agencies has led to the specification of a definitive radiometric calibration record for the Landsat-5 thematic mapper (TM) for its lifetime since launch in 1984. The time-dependent calibration record for Landsat-5 TM has been placed on the same radiometric scale as the Landsat-7 enhanced thematic mapper plus (ETM+). It has been implemented in the National Landsat Archive Production Systems (NLAPS) in use in North America. This paper documents the results of this collaborative effort and the specifications for the related calibration processing algorithms. The specifications include (i) anchoring of the Landsat-5 TM calibration record to the Landsat-7 ETM+ absolute radiometric calibration, (ii) new time-dependent calibration processing equations and procedures applicable to raw Landsat-5 TM data, and (iii) algorithms for recalibration computations applicable to some of the existing processed datasets in the North American context. The cross-calibration between Landsat-5 TM and Landsat-7 ETM+ was achieved using image pairs from the tandem-orbit configuration period that was programmed early in the Laridsat-7 mission. The time-dependent calibration for Landsat-5 TM is based on a detailed trend analysis of data from the on-board internal calibrator. The new lifetime radiometric calibration record for Landsat-5 will overcome problems with earlier product generation owing to inadequate maintenance and documentation of the calibration over time and will facilitate the quantitative examination of a continuous, near-global dataset at 30-m scale that spans almost two decades.

  2. Analysis of airborne radiometric data. Volume 2. Description, listing, and operating instructions for the code DELPHI/MAZAS. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Sperling, M.; Shreve, D.C.

    1978-12-01

    The computer code DELPHI is an interactive English language command system for the analysis of airborne radiometric data. The code includes modules for data reduction, data simulation, time filtering, data adjustment and graphical presentation of the results. DELPHI is implemented in FORTRAN on a DEC-10 computer. This volume gives a brief set of operations instructions, samples of the output obtained from hard copies of the display on a Tektronix terminal and finally a listing of the code.

  3. New argon-argon (40Ar/39Ar) radiometric age dates from selected subsurface basalt flows at the Idaho National Laboratory, Idaho

    Science.gov (United States)

    Hodges, Mary K.; Turrin, Brent D.; Champion, Duane E.; Swisher, Carl C.

    2015-01-01

    In 2011, the U.S. Geological Survey, in cooperation with the U.S. Department of Energy, collected samples for 12 new argon-argon radiometric ages from eastern Snake River Plain olivine tholeiite basalt flows in the subsurface at the Idaho National Laboratory. The core samples were collected from flows that had previously published paleomagnetic data. Samples were sent to Rutgers University for argon-argon radiometric dating analyses.

  4. Analysis of hyperspectral field radiometric data for monitoring nitrogen concentration in rice crops

    Science.gov (United States)

    Stroppiana, D.; Boschetti, M.; Confalonieri, R.; Bocchi, S.; Brivio, P. A.

    2005-10-01

    Monitoring crop conditions and assessing nutrition requirements is fundamental for implementing sustainable agriculture. Rational nitrogen fertilization is of particular importance in rice crops in order to guarantee high production levels while minimising the impact on the environment. In fact, the typical flooded condition of rice fields can be a significant source of greenhouse gasses. Information on plant nitrogen concentration can be used, coupled with information about the phenological stage, to plan strategies for a rational and spatially differentiated fertilization schedule. A field experiment was carried out in a rice field Northern Italy, in order to evaluate the potential of field radiometric measurements for the prediction of rice nitrogen concentration. The results indicate that rice reflectance is influenced by nitrogen supply at certain wavelengths although N concentration cannot be accurately predicted based on the reflectance measured at a given wavelength. Regression analysis highlighted that the visible region of the spectrum is most sensitive to plant nitrogen concentration when reflectance measures are combined into a spectral index. An automated procedure allowed the analysis of all the possible combinations into a Normalized Difference Index (NDI) of the narrow spectral bands derived by spectral resampling of field measurements. The derived index appeared to be least influenced by plant biomass and Leaf Area Index (LAI) providing a useful approach to detect rice nutritional status. The validation of the regressive model showed that the model is able to predict rice N concentration (R2=0.55 [p<0.01] RRMSE=29.4; modelling efficiency close to the optimum value).

  5. Determining water use of sorghum from two-source energy balance and radiometric temperatures

    Directory of Open Access Journals (Sweden)

    J. M. Sánchez

    2011-10-01

    Full Text Available Estimates of surface actual evapotranspiration (ET can assist in predicting crop water requirements. An alternative to the traditional crop-coefficient methods are the energy balance models. The objective of this research was to show how surface temperature observations can be used, together with a two-source energy balance model, to determine crop water use throughout the different phenological stages of a crop grown. Radiometric temperatures were collected in a sorghum (Sorghum bicolor field as part of an experimental campaign carried out in Barrax, Spain, during the 2010 summer growing season. Performance of the Simplified Two-Source Energy Balance (STSEB model was evaluated by comparison of estimated ET with values measured on a weighing lysimeter. Errors of ±0.14 mm h−1 and ±1.0 mm d−1 were obtained at hourly and daily scales, respectively. Total accumulated crop water use during the campaign was underestimated by 5%. It is then shown that thermal radiometry can provide precise crop water necessities and is a promising tool for irrigation management.

  6. A W-Band Radiometer with the Offset Parabolic Antenna for Radiometric Measurements

    Directory of Open Access Journals (Sweden)

    Li Wu

    2016-01-01

    Full Text Available This paper deals with the development of a W-band noise-adding radiometer which combines the millimeter-wave (MMW radiometric measurements with a high-resolution imager. The offset parabolic antenna is presented to achieve an accurate measurement and a high resolution. To reduce the cross-polarization level of the antenna, a multimode feed horn with a multistep structure is proposed to match the focal region fields of the reflector. It has advantages over the corrugated horns in lower mass and easier manufacturing. In addition, due to an unavoidable settling time for the noise-adding radiometer output signal passing through the low-pass filter, a theoretical criterion for the optimum duty cycle determination to reject extraneous contributions from the transient is proposed in this paper. The appropriate duty cycle threshold is 0.33 for the developed W-band radiometer. Also, a geometric correction method is presented to correct the obtained passive image suffering from a distortion for a better image interpretation. Preliminary experimental results are given to illustrate and verify the presented techniques.

  7. Radiometric in-situ calibration of satelital sensors of Earth observation using a spectroradiometer

    CERN Document Server

    Delgado-Correal, Camilo

    2012-01-01

    By using the satelital information of Earth observation unloaded by a station constructed in the country and reflectances measurements of the soil, we found the total radiation attenuation of the atmosphere for a small region of the Colombian territory. It was necessary to use the Fourier's theory that describes the ideal filters of signals to find the transfer functions between the spectral response of an spectroradiometer and the satelital sensor, whose radiative sign we are going to calibrate. After that, we used the reflectance spectrum of the soil taken with our spectroradiometer, the information in digital numbers (DN) of a pixel of the satelital image of the same region at the same time, and using again the theory of ideal filters we found the transfer function between the responses of both sensors to the radiance of the soil. The relation between both signals provides us the total intensity of the radiation attenuation of the atmosphere for pixel, which is fundamental to do a radiometric calibration o...

  8. NERO: General concept of a Near-Earth object Radiometric Observatory

    Science.gov (United States)

    Cellino, A.; Somma, R.; Tommasi, L.; Paolinetti, R.; Muinonen, K.; Virtanen, J.; Tedesco, E. F.; Delbò, M.

    Near-Earth objects Radiometric Observatory (NERO) is one of the six studies for possible missions dedicated to near-Earth objects, that were funded by the European Space Agency (ESA) in 2002 2003. It is a further development of some previous studies already submitted to ESA (Sysiphos, Spaceguard-1). The general concept is that a small satellite equipped with both a detector for visible wavelengths and an array for thermal IR measurements around 10 μm would be an ideal platform to obtain simultaneously two of the major objectives of current NEO science, namely the physical characterization of the objects and the discovery of those NEOs that are difficult to detect from the ground because their orbits are entirely or partly inside the Earth’s orbit. The NERO study includes a comprehensive analysis of the advantages and drawbacks of different orbital options for the satellite (including L2 of Earth and L2 of Venus) and a preliminary simulation of the effectiveness of orbit determination based on NERO observations of newly detected objects. The main results of this study, including also a preliminary sketch of the payload design (optics, detectors, cooling system, etc.) are briefly summarized.

  9. Evaluation of Radiometric Performance for the Thermal Infrared Sensor Onboard Landsat 8

    Directory of Open Access Journals (Sweden)

    Huazhong Ren

    2014-12-01

    Full Text Available The radiometric performance of remotely-sensed images is important for the applications of such data in monitoring land surface, ocean and atmospheric status. One requirement placed on the Thermal Infrared Sensor (TIRS onboard Landsat 8 was that the noise-equivalent change in temperature (NEΔT should be ≤0.4 K at 300 K for its two thermal infrared bands. In order to optimize the use of TIRS data, this study investigated the on-orbit NEΔT of the TIRS two bands from a scene-based method using clear-sky images over uniform ground surfaces, including lake, deep ocean, snow, desert and Gobi, as well as dense vegetation. Results showed that the NEΔTs of the two bands were 0.051 and 0.06 K at 300 K, which exceeded the design specification by an order of magnitude. The effect of NEΔT on the land surface temperature (LST retrieval using a split window algorithm was discussed, and the estimated NEΔT could contribute only 3.5% to the final LST error in theory, whereas the required NEΔT could contribute up to 26.4%. Low NEΔT could improve the application of TIRS images. However, efforts are needed in the future to remove the effects of unwanted stray light that appears in the current TIRS images.

  10. Radiometric compensation for cooperative distributed multi-projection system through 2-DOF distributed control.

    Science.gov (United States)

    Tsukamoto, Jun; Iwai, Daisuke; Kashima, Kenji

    2015-11-01

    This paper proposes a novel radiometric compensation technique for cooperative projection system based-on distributed optimization. To achieve high scalability and robustness, we assume cooperative projection environments such that 1. each projector does not have information about other projectors as well as target images, 2. the camera does not have information about the projectors either, while having the target images, and 3. only a broadcast communication from the camera to the projectors is allowed to suppress the data transfer bandwidth. To this end, we first investigate a distributed optimization based feedback mechanism that is suitable for the required decentralized information processing environment. Next, we show that this mechanism works well for still image projection, however not necessary for moving images due to the lack of dynamic responsiveness. To overcome this issue, we propose to implement an additional feedforward mechanism. Such a 2 Degree Of Freedom (2-DOF) control structure is well-known in control engineering community as a typical method to enhance not only disturbance rejection but also reference tracking capability, simultaneously. We theoretically guarantee and experimentally demonstrate that this 2-DOF structure yields the moving image projection accuracy that is overwhelming the best achievable performance only by the distributed optimization mechanisms.

  11. Radiometric calibration stability of the EO-1 advanced land imager: 5 years on-orbit

    Science.gov (United States)

    Markham, B.L.; Ong, L.; Barsi, J.A.; Mendenhall, J.A.; Lencioni, D.E.; Helder, D.L.; Hollaren, D.M.; Morfitt, R.

    2006-01-01

    The Advanced Land Imager (ALI) was developed as a prototype sensor for follow on missions to Landsat-7. It was launched in November 2000 on the Earth Observing One (EO-1) satellite as a nominal one-year technology demonstration mission. As of this writing, the sensor has continued to operate in excess of 5 years. Six of the ALl's nine multi-spectral (MS) bands and the panchromatic band have similar spectral coverage as those on the Landsat-7 ETM+. In addition to on-board lamps, which have been significantly more stable than the lamps on ETM+, the ALI has a solar diffuser and has imaged the moon monthly since launch. This combined calibration dataset allows understanding of the radiometric stability of the ALI system, its calibrators and some differentiation of the sources of the changes with time. The solar dataset is limited as the mechanism controlling the aperture to the solar diffuser failed approximately 18 months after launch. Results over 5 years indicate that: the shortest wavelength band (443 nm) has degraded in response about 2%; the 482 nm and 565 nm bands decreased in response about 1%; the 660 nm, 790 nm and 868 nm bands each degraded about 5%; the 1250 nm and 1650 nm bands did not change significantly and the 2215 nm band increased in response about 2%.

  12. Radiometric immunosorbent assay for the detection of anti-hormone-binding protein antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Pierce, E.A.; Dame, M.C.; DeLuca, H.F.

    1986-02-15

    A radiometric immunosorbent assay (RISA) for the detection of monoclonal antibodies to hormone-binding proteins has been developed. The assay involves incubating hybridoma supernatants in microtiter wells that have been coated with goat anti-mouse IgG antibodies. Any mouse IgG in the test supernatant is thus specifically retained in the wells. Radioactive ligand-binding protein complexes are then incubated in the wells. The presence of anti-binding protein antibodies in the supernatant is indicated by specific retention of radioactive ligand-binding protein complexes in the wells. Crude antigen preparations, such as tissue homogenates, can be used to detect antibodies. The assay is capable of detecting antibody at concentrations 20 ng/ml (approx. 100 pM IgG). The RISA has been used successfully to screen for monoclonal antibodies to the intracellular receptor for 1,25-dihydroxyvitamin D/sub 3/ and should be useful for the detection of antibodies to ligand-binding proteins in general.

  13. Radiometric and Geometric Analysis of Hyperspectral Imagery Acquired from an Unmanned Aerial Vehicle

    Directory of Open Access Journals (Sweden)

    Nancy F. Glenn

    2012-09-01

    Full Text Available In the summer of 2010, an Unmanned Aerial Vehicle (UAV hyperspectral calibration and characterization experiment of the Resonon PIKA II imaging spectrometer was conducted at the US Department of Energy’s Idaho National Laboratory (INL UAV Research Park. The purpose of the experiment was to validate the radiometric calibration of the spectrometer and determine the georegistration accuracy achievable from the on-board global positioning system (GPS and inertial navigation sensors (INS under operational conditions. In order for low-cost hyperspectral systems to compete with larger systems flown on manned aircraft, they must be able to collect data suitable for quantitative scientific analysis. The results of the in-flight calibration experiment indicate an absolute average agreement of 96.3%, 93.7% and 85.7% for calibration tarps of 56%, 24%, and 2.5% reflectivity, respectively. The achieved planimetric accuracy was 4.6 m (based on RMSE with a flying height of 344 m above ground level (AGL.

  14. New Radiometric Age Constraints for the Matuyama-Bruhnes Reversal and Santa Rosa Excursion

    Science.gov (United States)

    Balbas, A.; Koppers, A. A. P.; Kent, D. V.; Coe, R. S.; Konrad, K.; Clark, P. U.

    2015-12-01

    The coupling of the timing of the virtual geomagnetic pole (VGP) position and the absolute paleointensities for geomagnetic events is vital for understanding the Earth's geodynamo. Here we present new high-precision 40Ar/39Ar age determinations using an ARGUS-VI multi-collector mass spectrometer for lava flows on Floreana Island, Galapagos, and Tahiti Nui, Society Islands. New Galapagos ages (n=6) place the GA-79 lava flow on Floreana Island, which records an excursional VGP from an equatorial region (Cox and Dalrymple, 1966), within the Santa Rosa excursion. This flow contains extremely low paleointesity values of 1.1 x 1022 Am2 (n=11; Wang and Kent, 2013). We also present 52 new ages on 18 lava flows from the Punaruu valley, Tahiti, which record the Matuyama-Bruhnes reversal. The new ages confirm that the lavas record this reversal, but the ages differ from the original stratigraphy presented in Mochizuki et al. (2011). Our new ages using the Kuiper et al. (2008) fish canyon sanidine ages for Punaruu valley lava flows are concordant with previous astronomically tuned ages (Channell et al. 2002, 2009) and represent the highest precision radiometric ages for the most recent reversal. Here we show that paleointensity lows associated with excursional events can be comparable to or less than those associated with reversals. In addition, such field strength reductions can occur in time intervals as short as 3 thousand years.

  15. Radiometric Cross-calibration of KOMPSAT-3A with Landsat-8

    Science.gov (United States)

    Shin, D. Y.; Ahn, H. Y.; Lee, S. G.; Choi, C. U.; Kim, J. S.

    2016-06-01

    In this study, Cross calibration was conducted at the Libya 4 PICS site on 2015 using Landsat-8 and KOMPSAT-3A. Ideally a cross calibration should be calculated for each individual scene pair because on any given date the TOA spectral profile is influenced by sun and satellite view geometry and the atmospheric conditions. However, using the near-simultaneous images minimizes this effect because the sensors are viewing the same atmosphere. For the cross calibration, the calibration coefficient was calculated by comparing the at sensor spectral radiance for the same location calculated using the Landsat-8 calibration parameters in metadata and the DN of KOMPSAT-3A for the regions of interest (ROI). Cross calibration can be conducted because the satellite sensors used for overpass have a similar bandwidth. However, not all satellites have the same color filter transmittance and sensor reactivity, even though the purpose is to observe the visible bands. Therefore, the differences in the RSR should be corrected. For the cross-calibration, a calibration coefficient was calculated using the TOA radiance and KOMPSAT-3 DN of the Landsat-8 OLI overpassed at the Libya 4 Site, As a result, the accuracy of the calibration coefficient at the site was assumed to be ± 1.0%. In terms of the results, the radiometric calibration coefficients suggested here are thought to be useful for maintaining the optical quality of the KOMPSAT-3A.

  16. Application of gamma-ray spectrometry in a NORM industry for its radiometrical characterization

    Science.gov (United States)

    Mantero, J.; Gázquez, M. J.; Hurtado, S.; Bolívar, J. P.; García-Tenorio, R.

    2015-11-01

    Industrial activities involving Naturally Occurring Radioactive Materials (NORM) are found among the most important industrial sectors worldwide as oil/gas facilities, metal production, phosphate Industry, zircon treatment, etc. being really significant the radioactive characterization of the materials involved in their production processes in order to assess the potential radiological risk for workers or natural environment. High resolution gamma spectrometry is a versatile non-destructive radiometric technique that makes simultaneous determination of several radionuclides possible with little sample preparation. However NORM samples cover a wide variety of densities and composition, as opposed to the standards used in gamma efficiency calibration, which are either water-based solutions or standard/reference sources of similar composition. For that reason self-absorption correction effects (especially in the low energy range) must be considered individually in every sample. In this work an experimental and a semi-empirical methodology of self-absorption correction were applied to NORM samples, and the obtained results compared critically, in order to establish the best practice in relation to the circumstances of an individual laboratory. This methodology was applied in samples coming from a TiO2 factory (NORM industry) located in the south-west of Spain where activity concentration of several radionuclides from the Uranium and Thorium series through the production process was measured. These results will be shown in this work.

  17. Determining water use of sorghum from two-source energy balance and radiometric temperatures

    Science.gov (United States)

    Sánchez, J. M.; López-Urrea, R.; Rubio, E.; Caselles, V.

    2011-10-01

    Estimates of surface actual evapotranspiration (ET) can assist in predicting crop water requirements. An alternative to the traditional crop-coefficient methods are the energy balance models. The objective of this research was to show how surface temperature observations can be used, together with a two-source energy balance model, to determine crop water use throughout the different phenological stages of a crop grown. Radiometric temperatures were collected in a sorghum (Sorghum bicolor) field as part of an experimental campaign carried out in Barrax, Spain, during the 2010 summer growing season. Performance of the Simplified Two-Source Energy Balance (STSEB) model was evaluated by comparison of estimated ET with values measured on a weighing lysimeter. Errors of ±0.14 mm h-1 and ±1.0 mm d-1 were obtained at hourly and daily scales, respectively. Total accumulated crop water use during the campaign was underestimated by 5%. It is then shown that thermal radiometry can provide precise crop water necessities and is a promising tool for irrigation management.

  18. XRTD: An X-Windows based, real-time radiometric display and analysis system

    Science.gov (United States)

    Pollmeier, Vincent M.

    1993-01-01

    XRTD is a graphical user interface (GUI) based tool for monitoring real time radiometric spacecraft data. The tool is designed to allow the navigation analyst to both view and analyze the characteristics of Doppler and ranging data. This capability is critical if ground personnel wish to verify the correct performance of ongoing maneuvers. The raw tracking data is transferred from Deep Space Network (DSN) computers to a local workstation, where the predicted value for the observable is subtracted from the actual observed value to create a residual. The tool then allows the navigation analyst to rescale and replot the data using simple GUI techniques. The navigator may then perform a number of data analysis and modeling techniques on the resulting residuals to allow for the real time characterization of spacecraft events. These techniques include the modeling of maneuvers, the compression and differencing of data, and Fast Fourier transforms of the data. This tool has shortened the amount of time required for initial characterization of spacecraft maneuvers from several hours to a few minutes.

  19. Radiometric Short-Term Fourier Transform analysis of photonic Doppler velocimetry recordings and detectivity limit

    Science.gov (United States)

    Prudhomme, G.; Berthe, L.; Bénier, J.; Bozier, O.; Mercier, P.

    2017-01-01

    Photonic Doppler Velocimetry is a plug-and-play and versatile diagnostic used in dynamic physic experiments to measure velocities. When signals are analyzed using a Short-Time Fourier Transform, multiple velocities can be distinguished: for example, the velocities of moving particle-cloud appear on spectrograms. In order to estimate the back-scattering fluxes of target, we propose an original approach "PDV Radiometric analysis" resulting in an expression of time-velocity spectrograms coded in power units. Experiments involving micron-sized particles raise the issue of detection limit; particle-size limit is very difficult to evaluate. From the quantification of noise sources, we derive an estimation of the spectrogram noise leading to a detectivity limit, which may be compared to the fraction of the incoming power which has been back-scattered by the particle and then collected by the probe. This fraction increases with their size. At last, some results from laser-shock accelerated particles using two different PDV systems are compared: it shows the improvement of detectivity with respect to the Effective Number of Bits (ENOB) of the digitizer.

  20. Landsat 8 OLI radiometric calibration performance after three years (Conference Presentation)

    Science.gov (United States)

    Morfitt, Ron A.

    2016-09-01

    The Landsat 8 Operational Land Imager (OLI) impressed science users soon after launch in early 2013 with both its radiometric and geometric performance. After three years on-orbit, OLI continues to exceed expectations with its high signal-to-noise ratio, low striping, and stable response. The few artifacts that do exist, such as ghosting, continue to be minimal and show no signs of increasing. The on-board calibration sources showed a small decrease in response during the first six months of operations in the coastal aerosol band, but that decrease has stabilized to less than a half percent per year since that time. The other eight bands exhibit very little change over the past three years and have remained well within a half percent of their initial response to all on-board calibration sources. Analysis of lunar acquisitions also agree with the on-board calibrators. Overall, the OLI on-board the Landsat 8 spacecraft continues to provide exceptional measurements of the Earth's surface to continue the long tradition of Landsat.

  1. Assessment of Infrared Sounder Radiometric Noise from Analysis of Spectral Residuals

    Science.gov (United States)

    Dufour, E.; Klonecki, A.; Standfuss, C.; Tournier, B.; Serio, C.; Masiello, G.; Tjemkes, S.; Stuhlmann, R.

    2016-08-01

    For the preparation and performance monitoring of the future generation of hyperspectral InfraRed sounders dedicated to the precise vertical profiling of the atmospheric state, such as the Meteosat Third Generation hyperspectral InfraRed Sounder, a reliable assessment of the instrument radiometric error covariance matrix is needed.Ideally, an inflight estimation of the radiometrric noise is recommended as certain sources of noise can be driven by the spectral signature of the observed Earth/ atmosphere radiance. Also, unknown correlated noise sources, generally related to incomplete knowledge of the instrument state, can be present, so a caracterisation of the noise spectral correlation is also neeed.A methodology, relying on the analysis of post-retreival spectral residuals, is designed and implemented to derive in-flight the covariance matrix on the basis of Earth scenes measurements. This methodology is successfully demonstrated using IASI observations as MTG-IRS proxy data and made it possible to highlight anticipated correlation structures explained by apodization and micro-vibration effects (ghost). This analysis is corroborated by a parallel estimation based on an IASI black body measurement dataset and the results of an independent micro-vibration model.

  2. A study of elemental migration from poly(ethylene terephthalate) of food packagings to simulated solutions by radiometric method

    Energy Technology Data Exchange (ETDEWEB)

    Soares, Eufemia Paez [Escola SENAI Fundacao Zerrenner, Sao Paulo, SP (Brazil)]|[Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)], E-mail: eufemia@sp.senai.br; Saki, Mitiko; Silva, Leonardo G.A. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)], E-mail: mitiko@ipen.br, E-mail: lgasilva@ipen.br

    2007-07-01

    Brazilian plastic production for food packagings, in recent years, has grown in the same proportion as food consumption. Considering that the plastic manufacturing involves catalytic processes and the use of additives, when the foods are in direct contact with these materials, the components present in plastics may migrate to the food. The Brazilian Health Surveillance Agency (ANVISA) has established boundary-values of migrants as well as procedures to evaluate migration of elements and substances from plastic packaging to food. In this study elemental composition of poly (ethylene terephthalate) - PET - packaging and results of elemental migration were obtained. Instrumental Neutron Activation Analysis (INAA) was used to determine elemental concentrations in PET packagings and the radiometric method was applied for elemental migration determination. This radiometric method consisted of irradiating the PET samples with neutrons, followed by migration exposition and radioactivity measurement in food-simulated solution. Experimental conditions used for migration were 10 days exposure period at 40 deg C. Migration was evaluated for soft drink, juice and water PET packaging. The analytical results indicated that PET packagings contain Co and Sb and those elements are transferred to the simulated solutions. However, these migration results were lower than the maximum tolerance values established by ANVISA. The migration detection limits also indicated high sensitivity of the radiometric method. (author)

  3. Radiometric stability of the Multi-angle Imaging SpectroRadiometer (MISR) following 15 years on-orbit

    Science.gov (United States)

    Bruegge, Carol J.; Val, Sebastian; Diner, David J.; Jovanovic, Veljko; Gray, Ellyn; Di Girolamo, Larry; Zhao, Guangyu

    2014-09-01

    The Multi-angle Imaging SpectroRadiometer (MISR) has successfully operated on the EOS/ Terra spacecraft since 1999. It consists of nine cameras pointing from nadir to 70.5° view angle with four spectral channels per camera. Specifications call for a radiometric uncertainty of 3% absolute and 1% relative to the other cameras. To accomplish this, MISR utilizes an on-board calibrator (OBC) to measure camera response changes. Once every two months the two Spectralon panels are deployed to direct solar-light into the cameras. Six photodiode sets measure the illumination level that are compared to MISR raw digital numbers, thus determining the radiometric gain coefficients used in Level 1 data processing. Although panel stability is not required, there has been little detectable change in panel reflectance, attributed to careful preflight handling techniques. The cameras themselves have degraded in radiometric response by 10% since launch, but calibration updates using the detector-based scheme has compensated for these drifts and allowed the radiance products to meet accuracy requirements. Validation using Sahara desert observations show that there has been a drift of ~1% in the reported nadir-view radiance over a decade, common to all spectral bands.

  4. [In-Flight Radiometric Calibration for ZY-3 Satellite Multispectral Sensor by Modified Reflectance-Based Method].

    Science.gov (United States)

    Han, Jie; Xie, Yong; Gu, Xing-fa; Yu, Tao; Liu, Qi-yue; Gao, Rong-jun

    2015-03-01

    Through integrating multi-spectral sensor characteristics of ZY-3 satellite, a modified reflectance-based method is proposed and used to achieve ZY-3 satellite multispectral sensor in-flight radiometric calibration. This method chooses level 1A image as data source and establishes geometric model to get an accurate observation geometric parameters at calibration site according to the information provided in image auxiliary documentation, which can reduce the influences on the calibration accuracy from image resampling and observation geometry errors. We use two-point and multi-points methods to calculate the absolute radiometric calibration coefficients of ZY-3 satellite multispectral sensor based on the large campaign at Dongying city, Shan Dong province. Compared with ZY-3 official calibration coefficients, multi-points method has higher accuracy than two-point method. Through analyzing the dispersion between each calibration point and the fitting line, we find that the residual error of water calibration site is larger than others, which of green band is approximately 67.39%. Treating water calibration site as an error, we filter it out using 95.4% confidence level as standard and recalculate the calibration coefficients with multi-points method. The final calibration coefficients show that the relative differences of the first three bands are less than 2% and the last band is less than 5%, which manifests that the proposed radiometric calibration method can obtain accurate and reliable calibration coefficients and is useful for other similar satellites in future.

  5. Temporal dynamics of sand dune bidirectional reflectance characteristics for absolute radiometric calibration of optical remote sensing data

    Science.gov (United States)

    Coburn, Craig A.; Logie, Gordon; Beaver, Jason

    2016-09-01

    The use of Pseudo Invariant Calibration Sites (PICS) for establishing the radiometric trending of optical remote sensing systems has a long history of successful implementation. Past studies have shown that the PICS method is useful for evaluating the trend of sensors over time or cross-calibration of sensors but was not considered until recently for deriving absolute calibration. Current interest in using this approach to establish absolute radiometric calibration stems from recent research that indicates that with empirically derived models of the surface properties and careful atmospheric characterisation Top of Atmosphere (TOA) reflectance values can be predicted and used for absolute sensor radiometric calibration. Critical to the continued development of this approach is the accurate characterization of the Bidirectional Reflectance Distribution Function (BRDF) of PICS sites. This paper presents BRDF data collected by a high-performance portable goniometer system in order to develop a temporal BRDF model for the Algodones Dunes in California. The results demonstrated that the BRDF of a reasonably simple sand surface was complex with changes in anisotropy taking place in response to changing solar zenith angles. The nature of these complex interactions would present challenges to future model development.

  6. Development of radiometric assays for quantification of enzyme activities of the key enzymes of thyroid hormones metabolism.

    Science.gov (United States)

    Pavelka, S

    2014-01-01

    We newly elaborated and adapted several radiometric enzyme assays for the determination of activities of the key enzymes engaged in the biosynthesis (thyroid peroxidase, TPO) and metabolic transformations (conjugating enzymes and iodothyronine deiodinases, IDs) of thyroid hormones (THs) in the thyroid gland and in peripheral tissues, especially in white adipose tissue (WAT). We also elaborated novel, reliable radiometric methods for extremely sensitive determination of enzyme activities of IDs of types 1, 2 and 3 in microsomal fractions of different rat and human tissues, as well as in homogenates of cultured mammalian cells. The use of optimized TLC separation of radioactive products from the unconsumed substrates and film-less autoradiography of radiochromatograms, taking advantage of storage phosphor screens, enabled us to determine IDs enzyme activities as low as 10(-18) katals. In studies of the interaction of fluoxetine (Fluox) with the metabolism of THs, we applied adapted radiometric enzyme assays for iodothyronine sulfotransferases (ST) and uridine 5'-diphospho-glucuronyltransferase (UDP-GT). Fluox is the most frequently used representative of a new group of non-tricyclic antidepressant drugs--selective serotonin re-uptake inhibitors. We used the elaborated assays for quantification the effects of Fluox and for the assessment of the degree of potential induction of rat liver ST and/or UDP-GT enzyme activities by Fluox alone or in combination with T(3). Furthermore, we studied possible changes in IDs activities in murine adipose tissue under the conditions that promoted either tissue hypertrophy (obesogenic treatment) or involution (caloric restriction), and in response to leptin, using our newly developed radiometric enzyme assays for IDs. Our results suggest that deiodinase D1 has a functional role in WAT, with D1 possibly being involved in the control of adipose tissue metabolism and/or accumulation of the tissue. Significant positive correlation between

  7. Liquid Ventilation

    Directory of Open Access Journals (Sweden)

    Qutaiba A. Tawfic

    2011-01-01

    Full Text Available Mammals have lungs to breathe air and they have no gills to breath liquids. When the surface tension at the air-liquid interface of the lung increases, as in acute lung injury, scientists started to think about filling the lung with fluid instead of air to reduce the surface tension and facilitate ventilation. Liquid ventilation (LV is a technique of mechanical ventilation in which the lungs are insufflated with an oxygenated perfluorochemical liquid rather than an oxygen-containing gas mixture. The use of perfluorochemicals, rather than nitrogen, as the inert carrier of oxygen and carbon dioxide offers a number of theoretical advantages for the treatment of acute lung injury. In addition, there are non-respiratory applications with expanding potential including pulmonary drug delivery and radiographic imaging. The potential for multiple clinical applications for liquid-assisted ventilation will be clarified and optimized in future. Keywords: Liquid ventilation; perfluorochemicals; perfluorocarbon; respiratory distress; surfactant.

  8. Model-aided radiometric determination of photolysis frequencies in a sunlit atmosphere simulation chamber

    Directory of Open Access Journals (Sweden)

    B. Bohn

    2004-10-01

    Full Text Available In this work diurnal and seasonal variations of mean photolysis frequencies for the atmosphere simulation chamber SAPHIR at Forschungszentrum Jülich are calculated. SAPHIR has a complex construction with UV permeable teflon walls allowing natural sunlight to enter the reactor volume. The calculations are based on external measurements of solar spectral actinic flux and a model considering the time-dependent impact of shadows from construction elements as well as the influence of the teflon walls. Overcast and clear-sky conditions are treated in a consistent way and different assumptions concerning diffuse sky radiance distributions are tested. Radiometric measurements inside the chamber are used for an inspection of model predictions. Under overcast conditions we obtain 74% and 67% of external values for photolysis frequencies j(NO2 (NO2+hν→NO+O(3P and j(O1D (O3+hν→O2+O(1D, respectively. On a clear sky summer day these values are time-dependent within ranges 0.65–0.86 and 0.60–0.73, for j(NO2 and j(O1D, respectively. A succeeding paper (Bohn et al., 2004 is dealing with an on-road test of the model approach by comparison with photolysis frequencies from chemical actinometry experiments within SAPHIR.

  9. Radiometric reconnaissance in the Garfield and Taylor park quadrangles, Chaffee and Gunnison counties, Colorado

    Science.gov (United States)

    Dings, M.G.; Schafer, Max

    1953-01-01

    During the summer of 1952 most of the mines and prospects in the Garfield and Taylor Park quadrangles of west-central Colorado were examined radiometrically by the U. S. Geological Survey to determine the extent, grade, and mode of occurrence of radioactive substances. The region contains a relatively large number of rock types, chiefly pre-Cambrian schists, gneisses, and granites; large and small isolated areas of sedimentary rocks of Paleozoic and Mesozoic ages; and a great succession of intrusive rocks of Tertiary age that range from andesite to granite and occur as stocks, chonoliths, sills, dikes, and one batholith. The prevailing structures are northwest-trending folds and faults. Ores valued at about $30,000,000 have been produced from this region. Silver, lead, zinc, and gold have accounted for most of this value, but small tonnages of copper, tungsten, and molybdenum have also been produced. The principal ore minerals are sphalerite, silver-bearing galena, cerussite, smithsonite, and gold-bearing pyrite and limonite; they occur chiefly as replacement bodies in limestone and as shoots in pyritic quartz veins. Anomalous radioactivity is uncommon and the four localities at which it is known are widely separated in space. The uranium content of samples from these localities is low. Brannerite, the only uranium-bearing mineral positively identified in the region, occurs sparingly in a few pegmatites and in one quartz-beryl-pyrite vein. Elsewhere radioactivity is associated with (l) black shale seams in the Manitou dolomite, (2) a quartz-pyrite-molybdenite vein, (3) a narrow border zone of oxidized material surrounding a small lead zinc ore body in the Manitou dolomite along a strong fault zone.

  10. Radiometric evaluation of granite tables in environment public in the city of Recife-PE, Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Rocha, Edilson A.; Amaral, Romilton dos S.; Santos Junior, Jose A. dos; Bezerra, Jairo D., E-mail: accioly.edilson@ufpe.b, E-mail: romilton@ufpe.b, E-mail: jaraujo@ufpe.b, E-mail: jairo.dias@ufpe.b [Universidade Federal de Pernambuco (RAE/DEN/UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear. Grupo de Radioecologia

    2011-07-01

    Granite in Pernambuco has been used as raw-material in several utensils, amongst which, furniture and decoration objects. This granite, besides being traded internally, is also exported to Asia and Europe. Differentiated content of some radionuclides of the ({sup 238}U and {sup 232}Th) and {sup 40}K natural series above average content of other rocks is also commonly found, due to its origin and geological formation. The gamma radiation stems from the decay of the given series, followed by the {sup 40}K, and it should not exceed the 1 mSv.y{sup -1} limit per person of the public, according to the current radiological protection rules (ICRP, 60). This work aimed to radiometrically assess the granite tables used by the public of a well visited restaurant in the city of Recife. It is expected to contribute to the environmental monitoring and to assess the possible health risks for humans. The tables were monitored for a period of about one year. Dosimetric tablets of CaSO{sub 4}:Dy were used. The findings showed doses ranges from the background to 4.7 mSv.y{sup -1}, with general average of dose rate equal to 3.0 mSv.y{sup -1}. Therefore, it was concluded that despite the average dose rates in the different granite objects studied being higher than the recommended rate, the exposure does not offer risks to their users, due to the contact time (meal time) and the levels of radioactive emission found. (author)

  11. Radiometric and geometric assessment of data from the RapidEye constellation of satellites

    Science.gov (United States)

    Chander, Gyanesh; Haque, Md. Obaidul; Sampath, Aparajithan; Brunn, A.; Trosset, G.; Hoffmann, D.; Roloff, S.; Thiele, M.; Anderson, C.

    2013-01-01

    To monitor land surface processes over a wide range of temporal and spatial scales, it is critical to have coordinated observations of the Earth's surface using imagery acquired from multiple spaceborne imaging sensors. The RapidEye (RE) satellite constellation acquires high-resolution satellite images covering the entire globe within a very short period of time by sensors identical in construction and cross-calibrated to each other. To evaluate the RE high-resolution Multi-spectral Imager (MSI) sensor capabilities, a cross-comparison between the RE constellation of sensors was performed first using image statistics based on large common areas observed over pseudo-invariant calibration sites (PICS) by the sensors and, second, by comparing the on-orbit radiometric calibration temporal trending over a large number of calibration sites. For any spectral band, the individual responses measured by the five satellites of the RE constellation were found to differ Geometric assessment was also performed to study the positional accuracy and relative band-to-band (B2B) alignment of the image data sets. The position accuracy was assessed by comparing the RE imagery against high-resolution aerial imagery, while the B2B characterization was performed by registering each band against every other band to ensure that the proper band alignment is provided for an image product. The B2B results indicate that the internal alignments of these five RE bands are in agreement, with bands typically registered to within 0.25 pixels of each other or better.

  12. Millimeter-wave radiometric measurements of a treeline and building for aircraft obstacle avoidance

    Science.gov (United States)

    Wikner, David A.

    2003-08-01

    Passive millimeter-wave (MMW) imagers have the potential to be used on low-flying aircraft for terrain-following / terrain-avoidance during low-visibility conditions. This potential exists because of the inherent nature of MMW radiation that allows it to penetrate many visible and IR obscurants such as fog, clouds, and smoke. The phenomenology associated with this application, however, has not been fully explored. Specifically, the radiometric signatures of the various obstacles that might be encountered during a low-altitude flight need to be thoroughly understood. The work described in this paper explores the 93-GHz passive signature of a deciduous treeline and a concrete/glass building. The data were taken from the roof of a 4-story building to simulate the view of a low-flying aircraft. The data were collected over many months with an ARL-built Stokes-vector radiometer. This radiometer is a single-beam system that raster scans over a scene to collect a calibrated 93-GHz image. The data show the effects of weather and tree lifecycle on the 93-GHz brightness temperature contrast between the horizon sky and the obstacles. For the case of trees, it is shown that the horizon sky brightness temperature is greater than that of the trees when the leaves are on because of the reflective properties of the leaves. This made the trees quite detectable to our system during the late spring, summer, and early fall. Concrete buildings are inherently low-contrast obstacles because their vertical nature reflects the horizon behind the sensor and can easily mimic the forward horizon sky. Solar loading can have a large effect on building signatures.

  13. New radiometric dates for the Prehistory of Northwestern Iberia: Valdavara Cave (Becerreá, Lugo

    Directory of Open Access Journals (Sweden)

    Vaquero Rodríguez, Manuel

    2009-06-01

    Full Text Available The goal of this paper is to make known the first results of the excavations in Valdavara Cave (Becerreá, Lugo, paying special attention to the radiometric dating that places this cave among the few Galician sites with Upper Palaeolithic dates. During the excavation carried out in 2007, two archaeological locations were documented in the same karstic system (Valdavara 1 and Valdavara 2. The test pit initiated in Valdavara 1 allowed us to identify so far two stratigraphic units: an upper unit corresponding to Recent Prehistory and a lower unit (level 4 that yielded the Upper Palaeolithic dates. An assemblage of human remains from the Bronze Age was found in Valdavara 2.

    El objetivo de este artículo es dar a conocer los primeros resultados de las excavaciones en la cueva de Valdavara (Becerreá, Lugo, prestando especial atención a las dataciones radiométricas que la sitúan entre los pocos yacimientos gallegos que han arrojado fechas correspondientes al Paleolítico Superior. La excavación realizada en el año 2007 permitió documentar dos localizaciones arqueológicas en el marco del mismo sistema cárstico (Valdavara 1 y Valdavara 2. El sondeo iniciado en Valdavara 1 ha permitido identificar hasta el momento dos conjuntos estratigráficos: un conjunto superior correspondiente a la Prehistoria reciente y un conjunto inferior (nivel 4 en el que se han obtenido las fechas del Paleolítico Superior final. En Valdavara 2 se encontró un conjunto de restos humanos de la Edad del Bronce.

  14. Landsat-7 ETM+: 12 years on-orbit reflective-band radiometric performance

    Science.gov (United States)

    Markham, B.L.; Haque, M.O.; Barsi, J.A.; Micijevic, E.; Helder, D.L.; Thome, K.J.; Aaron, D.; Czapla-Myers, J. S.

    2012-01-01

    The Landsat-7 ETM+ sensor has been operating on orbit for more than 12 years, and characterizations of its performance have been ongoing over this period. In general, the radiometric performance of the instrument has been remarkably stable: 1) noise performance has degraded by 2% or less overall, with a few detectors displaying step changes in noise of 2% or less; 2) coherent noise frequencies and magnitudes have generally been stable, though the within-scan amplitude variation of the 20 kHz noise in bands 1 and 8 disappeared with the failure of the scan line corrector and a new similar frequency noise (now about 18 kHz) has appeared in two detectors in band 5 and increased in magnitude with time; 3) bias stability has been better than 0.25 DN out of a normal value of 15 DN in high gain; 4) relative gains, the differences in response between the detectors in the band, have generally changed by 0.1% or less over the mission, with the exception of a few detectors with a step response change of 1% or less; and 5) gain stability averaged across all detectors in a band, which is related to the stability of the absolute calibration, has been more stable than the techniques used to measure it. Due to the inability to confirm changes in the gain (beyond a few detectors that have been corrected back to the band average), ETM+ reflective band data continues to be calibrated with the prelaunch measured gains. In the worst case, some bands may have changed as much as 2% in uncompensated absolute calibration over the 12 years.

  15. Updated radiometric calibration for the Landsat-5 thematic mapper reflective bands

    Science.gov (United States)

    Helder, D.L.; Markham, B.L.; Thome, K.J.; Barsi, J.A.; Chander, G.; Malla, R.

    2008-01-01

    The Landsat-5 Thematic Mapper (TM) has been the workhorse of the Landsat system. Launched in 1984, it continues collecting data through the time frame of this paper. Thus, it provides an invaluable link to the past history of the land features of the Earth's surface, and it becomes imperative to provide an accurate radiometric calibration of the reflective bands to the user community. Previous calibration has been based on information obtained from prelaunch, the onboard calibrator, vicarious calibration attempts, and cross-calibration with Landsat-7. Currently, additional data sources are available to improve this calibration. Specifically, improvements in vicarious calibration methods and development of the use of pseudoinvariant sites for trending provide two additional independent calibration sources. The use of these additional estimates has resulted in a consistent calibration approach that ties together all of the available calibration data sources. Results from this analysis indicate a simple exponential, or a constant model may be used for all bands throughout the lifetime of Landsat-5 TM. Where previously time constants for the exponential models were approximately one year, the updated model has significantly longer time constants in bands 1-3. In contrast, bands 4, 5, and 7 are shown to be best modeled by a constant. The models proposed in this paper indicate calibration knowledge of 5% or better early in life, decreasing to nearly 2% later in life. These models have been implemented at the U.S. Geological Survey Earth Resources Observation and Science (EROS) and are the default calibration used for all Landsat TM data now distributed through EROS. ?? 2008 IEEE.

  16. Radiometric analysis of farmed fish (sea bass, gilthead bream, and rainbow trout) from Tenerife Island, Spain.

    Science.gov (United States)

    Jalili, A; López-Pérez, M; Karlsson, L; Hernández, F; Rubio, C; Hernández-Armas, J; Hardisson, A

    2009-09-01

    This study analyzed the content of gamma-emitting radionuclides in fish farmed on the island of Tenerife (Canary Islands, Spain). The fish species included in this study were sea bass, gilthead bream, and rainbow trout. The first two species are produced in offshore enclosures, while the third is produced in a freshwater fish farm. All measurements were performed using two high-purity germanium gamma-ray detectors. The content of gamma-emitting radionuclides in the fodder used to feed the different species of farmed fish studied was also determined. The following nuclides were often detected in the analyzed samples: 137Cs, 40K, 235U, 228Ac, 214Bi, 208Tl, 212Pb, and 214Pb. As a complement to this analysis, 210Po concentrations in two fish samples were determined by alpha spectrometry. The nuclide presenting the highest concentration was, as expected, the naturally occurring 40K, with an average concentration of 0.13 +/- 0.01 Bq/g (wet weight) (Bq/gww) in gilthead bream and sea bass and 0.12 +/- 0.01 Bq/gww in rainbow trout. The 235U concentrations determined in the same fish species were 0.6 +/- 0.5, 0.8 +/- 0.7, and 1.6 +/- 1.0 mBq/gww, respectively. This nuclide is seldom reported in fish samples. The concentrations of 137Cs (the only artificial nuclide determined in this study) in gilthead bream and sea bass were 0.026 +/- 0.006 and 0.044 +/- 0.01 mBq/gww, respectively. In addition to the radiometric analysis, the contribution of the analyzed nuclides to the effective dose from the mean daily intake of the fish was calculated. The calculated contribution, in terms of dose per person, produced by intake of the analyzed fish was 0.8 microSv/year. This value does not represent a significant risk to the local population.

  17. Radiometric evaluation of granite tables in environment public in the city of Recife-PE, Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Rocha, Edilson A.; Amaral, Romilton dos S.; Santos Junior, Jose A. dos; Bezerra, Jairo D., E-mail: accioly.edilson@ufpe.b, E-mail: romilton@ufpe.b, E-mail: jaraujo@ufpe.b, E-mail: jairo.dias@ufpe.b [Universidade Federal de Pernambuco (RAE/DEN/UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear. Grupo de Radioecologia

    2011-07-01

    Granite in Pernambuco has been used as raw-material in several utensils, amongst which, furniture and decoration objects. This granite, besides being traded internally, is also exported to Asia and Europe. Differentiated content of some radionuclides of the ({sup 238}U and {sup 232}Th) and {sup 40}K natural series above average content of other rocks is also commonly found, due to its origin and geological formation. The gamma radiation stems from the decay of the given series, followed by the {sup 40}K, and it should not exceed the 1 mSv.y{sup -1} limit per person of the public, according to the current radiological protection rules (ICRP, 60). This work aimed to radiometrically assess the granite tables used by the public of a well visited restaurant in the city of Recife. It is expected to contribute to the environmental monitoring and to assess the possible health risks for humans. The tables were monitored for a period of about one year. Dosimetric tablets of CaSO{sub 4}:Dy were used. The findings showed doses ranges from the background to 4.7 mSv.y{sup -1}, with general average of dose rate equal to 3.0 mSv.y{sup -1}. Therefore, it was concluded that despite the average dose rates in the different granite objects studied being higher than the recommended rate, the exposure does not offer risks to their users, due to the contact time (meal time) and the levels of radioactive emission found. (author)

  18. Challenges in the implementation of a quality management system applied to radiometric analysis

    Energy Technology Data Exchange (ETDEWEB)

    Dias, Danila C.S.; Bonifacio, Rodrigo L.; Nascimento, Marcos R.L.; Silva, Nivaldo C. da; Taddei, Maria Helena T., E-mail: danilacdias@gmail.com [Comissao Nacional de Energia Nuclear (LAPOC/CNEN-MG), Pocos de Caldas, MG (Brazil). Laboratorio de Pocos de Caldas

    2015-07-01

    The concept of quality in laboratories has been well established as an essential factor in the search for reliable results. Since its first version published (1999), the ISO/IEC 17025 has been applied in the industrial and research fields, in a wide range of laboratorial analyses. However, the implementation of a Quality Management System still poses great challenges to institutions and companies. The purpose of this work is to expose the constraints related to the implementation of ISO/IEC 17025 applied to analytical assays of radionuclides, accomplished by studying the case of the Pocos de Caldas Laboratory of the Brazilian Commission for Nuclear Energy. In this lab, a project of accreditation of techniques involving determination of radionuclides in water, soil, sediment and food samples has been conducted since 2011. The challenges presented by this project arise from the administrative view, where the governmental nature of the institution translates into unlevelled availability resources and the organizational view, whereas QMS requires inevitable changes in the organizational culture. It is important to point out that when it comes to accreditation of analysis involving radioactive elements, many aspects must be treated carefully due to the their very particular nature. Among these concerns are the determination of analysis uncertainties, accessibility to international proficiency studies, international radioactive samples and CRM transportation, the study of parameters on the validation of analytical methods and the lack of documentation and specialized personnel regarding quality at radiometric measurements. Through an effective management system, the institution is overcoming these challenges, moving toward the ISO/IEC 17025 accreditation. (author)

  19. Absolute radiometric calibration of Landsat using a pseudo invariant calibration site

    Science.gov (United States)

    Helder, D.; Thome, K.J.; Mishra, N.; Chander, G.; Xiong, Xiaoxiong; Angal, A.; Choi, Tae-young

    2013-01-01

    Pseudo invariant calibration sites (PICS) have been used for on-orbit radiometric trending of optical satellite systems for more than 15 years. This approach to vicarious calibration has demonstrated a high degree of reliability and repeatability at the level of 1-3% depending on the site, spectral channel, and imaging geometries. A variety of sensors have used this approach for trending because it is broadly applicable and easy to implement. Models to describe the surface reflectance properties, as well as the intervening atmosphere have also been developed to improve the precision of the method. However, one limiting factor of using PICS is that an absolute calibration capability has not yet been fully developed. Because of this, PICS are primarily limited to providing only long term trending information for individual sensors or cross-calibration opportunities between two sensors. This paper builds an argument that PICS can be used more extensively for absolute calibration. To illustrate this, a simple empirical model is developed for the well-known Libya 4 PICS based on observations by Terra MODIS and EO-1 Hyperion. The model is validated by comparing model predicted top-of-atmosphere reflectance values to actual measurements made by the Landsat ETM+ sensor reflective bands. Following this, an outline is presented to develop a more comprehensive and accurate PICS absolute calibration model that can be Système international d'unités (SI) traceable. These initial concepts suggest that absolute calibration using PICS is possible on a broad scale and can lead to improved on-orbit calibration capabilities for optical satellite sensors.

  20. Radiometric and spectrophotometric studies of the behavior of chromium(VI) oxide in concentrated perchloric acid

    Energy Technology Data Exchange (ETDEWEB)

    Pezzin, S.H.; Collins, C.H.; Collins, K.E. [Universidade Estadual de Campinas (Brazil). Inst. de Quimica; Archundia, C. [Universidad Nacional Autonoma de Mexico, Mexico City (Mexico). Inst. de Ciencias Nucleares

    1997-11-01

    A study of the behavior of {sup 51}CrO{sub 3} in 70% HClO{sub 4} over the temperature range from 20 to 194 C by means of Cr-51 labelling, UV-VIS spectrophotometry and ion exchange chromatography, shows that the solubility of {sup 51}CrO{sub 3} depends on a competition between the dissolution process and the acid reduction of solution phase Cr(VI). These processes occur simultaneously and are dependent on both the temperature and the concentration of Cr(VI), as shown by comparison between radiometric measurements (where total chromium can be accurately determined) and spectrophotometric measurements (where only the Cr(VI) is detectable at the wavelengths studied). These conclusions are confirmed by PbCrO{sub 4} precipitation of {sup 51}Cr(VI), where at 194 C, 97% of the total chromium appears as Pb{sup 51}CrO{sub 4} while at 86 C only 5% does. Cation exchange chromatography of the solution after brief contact of {sup 51}CrO{sub 3} with concentrated HClO{sub 4} at 20 C shows only traces of {sup 51}Cr(VI), most of the radioactivity eluting as {sup 51}Cr(H{sub 2}O){sup 3+}{sub 6}, with smaller amounts of species with +2 and +1 charges. These results imply serious limitations to the spectrophotometric determination of low concentrations of total chromium in alloys or in biological material which use dissolution in 70% HClO{sub 4} as a primary analytical step. (orig.)

  1. In-flight absolute radiometric calibration of MODIS using the irradiance-based method

    Science.gov (United States)

    Wei, Wei; Li, Xin; Zhao, Chun-yan; Qiu, Gang-gang; Zheng, Xiao-bing

    2016-10-01

    In order to reduce the calibration uncertainty of the reflectance-based method brought by the assumption of the aerosol model, the irradiance-based method, known as improved reflectance-based method, was proposed. The irradiance-based method is described in this paper. The radiometric calibration field campaign was performed at Dunhuang test site on 27 August, 2014. A hyperspectral irradiance meter (HSIM) developed by Anhui Institute of Optics and Fine Mechanics (AIOFM) was used to measure the diffuse-to-global spectral irradiance ratio. The irradiance-based method and the reflectance-based method were performed to calibrate the first four bands of Moderate Resolution Imaging Spectroradiometer (MODIS). The results of two methods were compared with result of MODIS on-board calibrator. The comparison shows that the result of irradiance-based method has a good consistency with on-board calibration and reflectance-based method results. The difference of calibration coefficients between irradiance-based and on-board method was less than 1.4%. Due to the limitations of the irradiance-based method, a clear sky and stable atmospheric condition is required for the entire half of the calibration day to provide the data necessary for the extrapolation of diffuse-to-global ratio in viewing direction. A study on the effects of aerosol mode assumption on the final apparent reflectance was performed on both the irradiance-based method and the reflectance-based method by selecting different aerosol modes to predict the apparent reflectance. The results show that aerosol mode assumption has a great effect on the reflectance-based method, however slight effect on the irradiance-based method.

  2. Subsidizing Liquidity

    DEFF Research Database (Denmark)

    Malinova, Katya; Park, Andreas

    2015-01-01

    Facing increased competition over the last decade, many stock exchanges changed their trading fees to maker-taker pricing, an incentive scheme that rewards liquidity suppliers and charges liquidity demanders. Using a change in trading fees on the Toronto Stock Exchange, we study whether and why...

  3. Mise en pratique for the definition of the candela and associated derived units for photometric and radiometric quantities in the International System of Units (SI)

    Science.gov (United States)

    Zwinkels, Joanne; Sperling, Armin; Goodman, Teresa; Campos Acosta, Joaquin; Ohno, Yoshi; Rastello, Maria Luisa; Stock, Michael; Woolliams, Emma

    2016-06-01

    The purpose of this mise en pratique, prepared by the Consultative Committee for Photometry and Radiometry (CCPR) of the International Committee for Weights and Measures (CIPM) and formally adopted by the CIPM, is to provide guidance on how the candela and related units used in photometry and radiometry can be realized in practice. The scope of the mise en pratique recognizes the fact that the two fields of photometry and radiometry and their units are closely related through the current definition of the SI base unit for the photometric quantity, luminous intensity: the candela. The previous version of the mise en pratique was applied only to the candela whereas this updated version covers the realization of the candela and other related units used for photometric and radiometric quantities. Recent advances in the generation and manipulation of individual photons show great promise of producing radiant fluxes with a well-established number of photons. Thus, this mise en pratique also includes information on the practical realization of units for photometric and radiometric quantities using photon-number-based techniques. In the following, for units used for photometric and radiometric quantities, the shorter term, photometric and radiometric units, is generally used. Section 1 describes the definition of the candela which introduces a close relationship between photometric and radiometric units. Sections 2 and 3 describe the practical realization of radiometric and photon-number-based units, respectively. Section 4.1 explains how, in general, photometric units are derived from radiometric units. Sections 4.2-4.5 deal with the particular geometric conditions for the specific photometric units. Section 5 deals very briefly with the topic of determination of measurement uncertainties in photometry.

  4. Liquid pearls

    CERN Document Server

    Bremond, Nicolas; Bibette, Jérôme

    2010-01-01

    This fluid dynamics video reports how to form liquid core capsules having a thin hydrogel elastic membrane named liquid pearls. These fish-egg like structures are initially made of a millimetric liquid drop, aqueous or not, coated with an aqueous liquid film containing sodium alginate that gels once the double drop enters a calcium chloride bath. The creation of such pearls with micrometer thick membrane requires to suppress mixing until gelling takes place. Here, we show that superimposing a two dimensional surfactant precipitation at the interface confers a transient rigidity that can damp the shear induced instability at impact. Based on this, pearls containing almost any type of liquids can be created. The video focuses on the dynamics of the entry of the compound drop into the gelling bath.

  5. A Detailed Radiometric Chronological Framework for Nordic Seas Ocean-Ice Sheet Interactions Spanning 50-150 Ka BP

    Science.gov (United States)

    Brendryen, J.; Edwards, R. L.; Haflidason, H.; Cheng, H.; Grasmo, K. J.; Sejrup, H. P.

    2014-12-01

    Chronological control of sedimentary deposits is a key to do paleoclimatic interpretations of proxy records and to compare them with records from other archives. Beyond the reach of radiocarbon dating there are however few options for developing chronological control. We present a detailed radiometrical-based chronological framework of a Norwegian Sea core archive that records ocean-ice sheet interactions in the Nordic Seas covering the time span 50-150 ka BP. The chronology is based on a detailed multi-proxy and multi-archive alignment of high resolution records from the Norwegian Sea and precisely radiometric dated speleothem δ18O record from both China and the Alps. This approach utilizes the close and well documented millennial and multi-centennial scale coupling between the North Atlantic climate variability (recorded in the Norwegian Sea records, the Greenland ice cores and in the Alpine speleothems) and the Asian Monsoon system recorded in the Chinese speleothem δ18O. One intriguing feature of the Norwegian Sea record is that it often is more similar to the Chinese speleothem records than to the Greenland ice core records. The alignment is aided by a tephrostratigraphic link to the Greenland ice cores which provide an independent test of the age model and alignment. Uncertainties are addressed by Bayesian age-depth modeling. The radiometric-based age model and the quantified uncertainties enable an independent comparison between the Nordic Seas ocean-ice sheet interaction and other absolutely dated records such as U/Th dated sea-level indices and orbital parameters. This improves our ability to interpret the ocean-ice sheet interactions of the polar north in a global context over this time span that comprises a glacial-interglacial cycle.

  6. Evaluation of Radiometric and Atmospheric Correction Algorithms for Aboveground Forest Biomass Estimation Using Landsat 5 TM Data

    Directory of Open Access Journals (Sweden)

    Pablito M. López-Serrano

    2016-04-01

    Full Text Available Solar radiation is affected by absorption and emission phenomena during its downward trajectory from the Sun to the Earth’s surface and during the upward trajectory detected by satellite sensors. This leads to distortion of the ground radiometric properties (reflectance recorded by satellite images, used in this study to estimate aboveground forest biomass (AGB. Atmospherically-corrected remote sensing data can be used to estimate AGB on a global scale and with moderate effort. The objective of this study was to evaluate four atmospheric correction algorithms (for surface reflectance, ATCOR2 (Atmospheric Correction for Flat Terrain, COST (Cosine of the Sun Zenith Angle, FLAASH (Fast Line-of-sight Atmospheric Analysis of Spectral Hypercubes and 6S (Second Simulation of Satellite Signal in the Solar, and one radiometric correction algorithm (for reflectance at the sensor ToA (Apparent Reflectance at the Top of Atmosphere to estimate AGB in temperate forest in the northeast of the state of Durango, Mexico. The AGB was estimated from Landsat 5 TM imagery and ancillary information from a digital elevation model (DEM using the non-parametric multivariate adaptive regression splines (MARS technique. Field reference data for the model training were collected by systematic sampling of 99 permanent forest growth and soil research sites (SPIFyS established during the winter of 2011. The following predictor variables were identified in the MARS model: Band 7, Band 5, slope (β, Wetness Index (WI, NDVI and MSAVI2. After cross-validation, 6S was found to be the optimal model for estimating AGB (R2 = 0.71 and RMSE = 33.5 Mg·ha−1; 37.61% of the average stand biomass. We conclude that atmospheric and radiometric correction of satellite images can be used along with non-parametric techniques to estimate AGB with acceptable accuracy.

  7. Managing liquidity

    DEFF Research Database (Denmark)

    Pokutta, Sebastian; Schmaltz, Christian

    2011-01-01

    Large banking groups face the question of how to optimally allocate and generate liquidity: in a central liquidity hub or in many decentralized branches. We translate this question into a facility location problem under uncertainty. We show that volatility is the key driver behind (de...... above which it is advantageous to open a liquidity center and show that it is a function of the volatility and the characteristic of the bank network. Finally, we discuss the n-branch model for real-world banking groups (10-60 branches) and show that it can be solved with high granularity (100 scenarios...

  8. Patch Antenna for Measuring the Internal Temperature of Biological Objects Using the Near-Field Microwave Radiometric Method

    Science.gov (United States)

    Ubaichin, A.; Bespalko, A.; Filatov, A.; Alexeev, E.; Zhuk, G.

    2016-01-01

    The near-field microwave antenna with central frequency of 2.23 GHz has been designed and manufactured to be used as a part of the medical microwave radiometric system. Experimental studies of the reflection coefficient in different parts of the human body were conducted using the developed antenna. The experimental studies were carried out in a group of volunteers with normal somatic growth. The results of the experiments were used to perform the analysis of the potential errors in the measurements obtained via the developed antenna.

  9. Determination of dentifrice abrasivity indices by radiometric method; Determinacao de indices de abrasividade de dentifricios pelo metodo radiometrico

    Energy Technology Data Exchange (ETDEWEB)

    Camargo, Iara M.C. de; Saiki, Mitiko; Avila, Daniela M.; Vasconcellos, Marina B.A. [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil); Panzeri, Heitor; Lara, Elza H.G. [Faculdade de Odontologia, Ribeirao Preto, SP (Brazil)

    1996-07-01

    This paper consists on the application of a radiometric method to the evaluation of dentifrice abrasivity in order to bring this technique in Brazil. It is a method recommended by the American Dental Association (ADA) from the USA. The precision of the abrasivity indices (RDA) was satisfactory, providing values that varied from 1.4 to 15.1%. The dentifrices analyzed presented RDA values between 33 and 88, therefore, they were within the limit value established by ADA, 250. A correlation between RDA values of raw materials and size of their particles was observed. (author)

  10. The Moon Mineralogy (M3) Imaging Spectrometer: Early Assessment of the Spectral, Radiometric, Spatial and Uniformity Properties

    Science.gov (United States)

    Green, Robert O.; Pieters, C. M.; Boardman, J.; Barr, D.; Bruce, C.; Bousman, J.; Chatterjee, A.; Eastwood, M.; Essandoh, V.; Geier, S.; Glavich, T.; Green, R.; Haemmerle, V.; Hyman, S.; Hovland, L.; Koch, T.; Lee, K.; Lundeen, S.; Motts, E.; Mouroulis, P.; Paulson, S.; Plourde, K.; Racho, C.; Robinson, D.; Rodriquez, J.

    2009-01-01

    The Moon Mineralogy Mapper's (M3) is a high uniformity and high signal-to-noise ratio NASA imaging spectrometer that is a guest instrument on the Indian Chandrayaan-1 Mission to the Moon. The laboratory measured spectral, radiometric, spatial, and uniformity characteristics of the M3 instrument are given. The M3 imaging spectrometer takes advantage of a suite of critical enabling capabilities to achieve its measurement requirement with a mass of 8 kg, power usage of 15 W, and volume of 25X18X12 cm. The M3 detector and spectrometer are cooled by a multi-stage passive cooler. This paper presents early M3 performance assessment results.

  11. GOSAT TIR radiometric validation toward simultaneous GHG column and profile observation

    Science.gov (United States)

    Kataoka, F.; Knuteson, R. O.; Kuze, A.; Shiomi, K.; Suto, H.; Saitoh, N.

    2015-12-01

    The Greenhouse gases Observing SATellite (GOSAT) was launched on January 2009 and continues its operation for more than six years. The thermal and near infrared sensor for carbon observation Fourier-Transform Spectrometer (TANSO-FTS) onboard GOSAT measures greenhouse gases (GHG), such as CO2 and CH4, with wide and high resolution spectra from shortwave infrared (SWIR) to thermal infrared (TIR). This instrument has the advantage of being able to measure simultaneously the same field of view in different spectral ranges. The combination of column-GHG form SWIR band and vertical profile-GHG from TIR band provide better understanding and distribution of GHG, especially in troposphere. This work describes the radiometric validation and sensitivity analysis of TANSO-FTS TIR spectra, especially CO2, atmospheric window and CH4 channels with forward calculation. In this evaluation, we used accurate in-situ dataset of the HIPPO (HIAPER Pole-to-Pole Observation) airplane observation data and GOSAT vicarious calibration and validation campaign data in Railroad Valley, NV. The HIPPO aircraft campaign had taken accurate atmospheric vertical profile dataset (T, RH, O3, CO2, CH4, N2O, CO) approximately pole-to-pole from the surface to the tropopause over the ocean. We implemented these dataset for forward calculation and made the spectral correction model with respect to wavenumber and internal calibration blackbody temperature The GOSAT vicarious calibration campaign have conducted every year since 2009 near summer solstice in Railroad Valley, where high-temperature desert site. In this campaign, we have measured temperature and humidity by a radiosonde and CO2, CH4 and O3 profile by the AJAX airplane at the time of the GOSAT overpass. Sometimes, the GHG profiles over the Railroad Valley show the air mass advection in mid-troposphere depending on upper wind. These advections bring the different concentration of GHG in lower and upper troposphere. Using these cases, we made

  12. Assessment and Correction of on-Orbit Radiometric Calibration for FY-3 VIRR Thermal Infrared Channels

    Directory of Open Access Journals (Sweden)

    Na Xu

    2014-03-01

    Full Text Available FengYun-3 (FY-3 Visible Infrared Radiometer (VIRR, along with its predecessor, Multispectral Visible Infrared Scanning Radiometer (MVISR, onboard FY-1C&D have had continuous global observation more than 14 years. This data record is valuable for weather prediction, climate monitoring, and environment research. Data quality is vital for satellite data assimilations in Numerical Weather Prediction (NWP and quantitative remote sensing applications. In this paper, the accuracies of radiometric calibration for VIRR onboard FY-3A and FY-3B, in thermal infrared (TIR channels, are evaluated using the Low Earth Orbit (LEO-LEO simultaneous nadir overpass intercalibration method. Hyperspectral and high-quality observations from Infrared Atmosphere Sounding Instrument (IASI onboard METOP-A are used as reference. The biases of VIRR measurements with respect to IASI over one-and-a-half years indicate that the TIR calibration accuracy of FY-3B VIRR is better than that of FY-3A VIRR. The brightness temperature (BT measured by FY-3A/VIRR is cooler than that measured by IASI with monthly mean biases ranging from −2 K to −1 K for channel 4 and −1 K to 0.2 K for channel 5. Measurements from FY-3B/VIRR are more consistent with that from IASI, and the annual mean biases are 0.84 ± 0.16 K and −0.66 ± 0.18 K for channels 4 and 5, respectively. The BT biases of FY-3A/VIRR show scene temperature-dependence and seasonal variation, which are not found from FY-3B/VIRR BT biases. The temperature-dependent biases are shown to be attributed to the nonlinearity of detectors. New nonlinear correction coefficients of FY-3A/VIRR TIR channels are reevaluated using various collocation samples. Verification results indicate that the use of the new nonlinear correction can greatly correct the scene temperature-dependent and systematic biases.

  13. Analysis of the topographic effect on the radiometric correction of MERIS images

    Directory of Open Access Journals (Sweden)

    G. Grau

    2014-12-01

    Full Text Available Topography alters the vertical structure of the atmosphere and, therefore, its radiative properties regarding the reflection and transmission of the solar radiation. Also it modifies the conditions of illumination of terrain, with remarkable influence in the remote sensing measures of the terrestrial surface in the optical spectrum. In this work we have applied two models of atmospheric and radiometric correction on an ENVISAT/MERIS image, considering the topography, to analyse the importance of such effects. For this, we have exploited the recent rise of Digital Models of Elevation (MDE sufficiently detailed and precise, available to a global scale, that open new prospects for the topographical corrections of remote sensing data. The results show the adjustment of the conjoint correction model (atmospheric and topographical in the considered case, improving comparison of spectral signatures of similar surfaces independently of the elevation or the conditions of illumination, compensating the relative variations caused by the topography in the reflectivity measured by sensors. Although the remote sensing of the terrestrial surface has tended traditionally to avoid the bands of atmospheric absorption, a peculiarity that presents the ENVISAT/MERIS images is the availability of a band (O2A of absorption of the oxygen, located in the 761.5 nm. This band is used mainly for atmospheric corrections (estimate of the surface’s pressure, elevation of clouds, aerosols effects, etc.. But also it has been employed recently to determine the fluorescence of the vegetation, consequently this band of absorption has received remarkable attention in the last years. Considering that this absorption of the oxygen is strongly affected for topography, the determination of information on the terrestrial surface from this absorption of the oxygen requires a very precise correction of the topographical effects. Therefore in this work we analyse in particular the effect

  14. Radiometric inter-sensor cross-calibration uncertainty using a traceable high accuracy reference hyperspectral imager

    Science.gov (United States)

    Gorroño, Javier; Banks, Andrew C.; Fox, Nigel P.; Underwood, Craig

    2017-08-01

    Optical earth observation (EO) satellite sensors generally suffer from drifts and biases relative to their pre-launch calibration, caused by launch and/or time in the space environment. This places a severe limitation on the fundamental reliability and accuracy that can be assigned to satellite derived information, and is particularly critical for long time base studies for climate change and enabling interoperability and Analysis Ready Data. The proposed TRUTHS (Traceable Radiometry Underpinning Terrestrial and Helio-Studies) mission is explicitly designed to address this issue through re-calibrating itself directly to a primary standard of the international system of units (SI) in-orbit and then through the extension of this SI-traceability to other sensors through in-flight cross-calibration using a selection of Committee on Earth Observation Satellites (CEOS) recommended test sites. Where the characteristics of the sensor under test allows, this will result in a significant improvement in accuracy. This paper describes a set of tools, algorithms and methodologies that have been developed and used in order to estimate the radiometric uncertainty achievable for an indicative target sensor through in-flight cross-calibration using a well-calibrated hyperspectral SI-traceable reference sensor with observational characteristics such as TRUTHS. In this study, Multi-Spectral Imager (MSI) of Sentinel-2 and Landsat-8 Operational Land Imager (OLI) is evaluated as an example, however the analysis is readily translatable to larger-footprint sensors such as Sentinel-3 Ocean and Land Colour Instrument (OLCI) and Visible Infrared Imaging Radiometer Suite (VIIRS). This study considers the criticality of the instrumental and observational characteristics on pixel level reflectance factors, within a defined spatial region of interest (ROI) within the target site. It quantifies the main uncertainty contributors in the spectral, spatial, and temporal domains. The resultant tool

  15. Liquid explosives

    CERN Document Server

    Liu, Jiping

    2015-01-01

    The book drawing on the author's nearly half a century of energetic materials research experience intends to systematically review the global researches on liquid explosives. The book focuses on the study of the conception, explosion mechanism, properties and preparation of liquid explosives. It provides a combination of theoretical knowledge and practical examples in a reader-friendly style. The book is likely to be interest of university researchers and graduate students in the fields of energetic materials, blasting engineering and mining.

  16. A comparison of radiometric correction techniques in the evaluation of the relationship between LST and NDVI in Landsat imagery.

    Science.gov (United States)

    Tan, Kok Chooi; Lim, Hwee San; Matjafri, Mohd Zubir; Abdullah, Khiruddin

    2012-06-01

    Atmospheric corrections for multi-temporal optical satellite images are necessary, especially in change detection analyses, such as normalized difference vegetation index (NDVI) rationing. Abrupt change detection analysis using remote-sensing techniques requires radiometric congruity and atmospheric correction to monitor terrestrial surfaces over time. Two atmospheric correction methods were used for this study: relative radiometric normalization and the simplified method for atmospheric correction (SMAC) in the solar spectrum. A multi-temporal data set consisting of two sets of Landsat images from the period between 1991 and 2002 of Penang Island, Malaysia, was used to compare NDVI maps, which were generated using the proposed atmospheric correction methods. Land surface temperature (LST) was retrieved using ATCOR3_T in PCI Geomatica 10.1 image processing software. Linear regression analysis was utilized to analyze the relationship between NDVI and LST. This study reveals that both of the proposed atmospheric correction methods yielded high accuracy through examination of the linear correlation coefficients. To check for the accuracy of the equation obtained through linear regression analysis for every single satellite image, 20 points were randomly chosen. The results showed that the SMAC method yielded a constant value (in terms of error) to predict the NDVI value from linear regression analysis-derived equation. The errors (average) from both proposed atmospheric correction methods were less than 10%.

  17. Transmittance Measurement of a Heliostat Facility used in the Preflight Radiometric Calibration of Earth-Observing Sensors

    Science.gov (United States)

    Czapla-Myers, J.; Thome, K.; Anderson, N.; McCorkel, J.; Leisso, N.; Good, W.; Collins, S.

    2009-01-01

    Ball Aerospace and Technologies Corporation in Boulder, Colorado, has developed a heliostat facility that will be used to determine the preflight radiometric calibration of Earth-observing sensors that operate in the solar-reflective regime. While automatically tracking the Sun, the heliostat directs the solar beam inside a thermal vacuum chamber, where the sensor under test resides. The main advantage to using the Sun as the illumination source for preflight radiometric calibration is because it will also be the source of illumination when the sensor is in flight. This minimizes errors in the pre- and post-launch calibration due to spectral mismatches. It also allows the instrument under test to operate at irradiance values similar to those on orbit. The Remote Sensing Group at the University of Arizona measured the transmittance of the heliostat facility using three methods, the first of which is a relative measurement made using a hyperspectral portable spectroradiometer and well-calibrated reference panel. The second method is also a relative measurement, and uses a 12-channel automated solar radiometer. The final method is an absolute measurement using a hyperspectral spectroradiometer and reference panel combination, where the spectroradiometer is calibrated on site using a solar-radiation-based calibration.

  18. Hierarchical Bayesian Data Analysis in Radiometric SAR System Calibration: A Case Study on Transponder Calibration with RADARSAT-2 Data

    Directory of Open Access Journals (Sweden)

    Björn J. Döring

    2013-12-01

    Full Text Available A synthetic aperture radar (SAR system requires external absolute calibration so that radiometric measurements can be exploited in numerous scientific and commercial applications. Besides estimating a calibration factor, metrological standards also demand the derivation of a respective calibration uncertainty. This uncertainty is currently not systematically determined. Here for the first time it is proposed to use hierarchical modeling and Bayesian statistics as a consistent method for handling and analyzing the hierarchical data typically acquired during external calibration campaigns. Through the use of Markov chain Monte Carlo simulations, a joint posterior probability can be conveniently derived from measurement data despite the necessary grouping of data samples. The applicability of the method is demonstrated through a case study: The radar reflectivity of DLR’s new C-band Kalibri transponder is derived through a series of RADARSAT-2 acquisitions and a comparison with reference point targets (corner reflectors. The systematic derivation of calibration uncertainties is seen as an important step toward traceable radiometric calibration of synthetic aperture radars.

  19. Transmittance measurement of a heliostat facility used in the preflight radiometric calibration of Earth-observing sensors

    Science.gov (United States)

    Czapla-Myers, J.; Thome, K.; Anderson, N.; McCorkel, J.; Leisso, N.; Good, W.; Collins, S.

    2009-08-01

    Ball Aerospace and Technologies Corporation in Boulder, Colorado, has developed a heliostat facility that will be used to determine the preflight radiometric calibration of Earth-observing sensors that operate in the solar-reflective regime. While automatically tracking the Sun, the heliostat directs the solar beam inside a thermal vacuum chamber, where the sensor under test resides. The main advantage to using the Sun as the illumination source for preflight radiometric calibration is because it will also be the source of illumination when the sensor is in flight. This minimizes errors in the pre- and post-launch calibration due to spectral mismatches. It also allows the instrument under test to operate at irradiance values similar to those on orbit. The Remote Sensing Group at the University of Arizona measured the transmittance of the heliostat facility using three methods, the first of which is a relative measurement made using a hyperspectral portable spectroradiometer and well-calibrated reference panel. The second method is also a relative measurement, and uses a 12-channel automated solar radiometer. The final method is an absolute measurement using a hyperspectral spectroradiometer and reference panel combination, where the spectroradiometer is calibrated on site using a solar-radiation-based calibration.

  20. Radiometric calibration of IR Fourier transform spectrometers - Solution to a problem with the High-Resolution Interferometer Sounder

    Science.gov (United States)

    Revercomb, Henry E.; Smith, William L.; Buijs, H.; Howell, Hugh B.; Laporte, D. D.

    1988-01-01

    A calibrated Fourier transform spectrometer, known as the High-Resolution Interferometer Sounder (HIS), has been flown on the NASA U-2 research aircraft to measure the infrared emission spectrum of the earth. The primary use - atmospheric temperature and humidity sounding - requires high radiometric precision and accuracy (of the order of 0.1 and 1 C, respectively). To meet these requirements, the HIS instruments, the HIS instrument performs inflight radiometric calibration, using observations of hot and cold blackbody reference sources as the basis for two-point calibrations at each wavenumber. Initially, laboratory tests revealed a calibration problem with brightness temperature errors as large as 15 C between 600 and 900/cm. The symptom of the problem, which occurred in one of the three spectral bands of HIS, was a source-dependent phase response. Minor changes to the calibration equations completely eliminated the anomalous errors. The new analysis properly accounts for the situation in which the phase response for radiance from the instrument itself differs from that for radiance from an external source. The mechanism responsible for the dual phase response of the HIS instrument is identified as emission from the interferometer beam splitter.

  1. Level 0 to 1 processing of the imaging Fourier transform spectrometer GLORIA: generation of radiometrically and spectrally calibrated spectra

    Directory of Open Access Journals (Sweden)

    A. Kleinert

    2014-12-01

    Full Text Available The Gimballed Limb Observer for Radiance Imaging of the Atmosphere (GLORIA is an imaging Fourier transform spectrometer that is capable of operating on various high-altitude research aircraft. It measures the atmospheric emission in the thermal infrared spectral region in limb and nadir geometry. GLORIA consists of a classical Michelson interferometer combined with an infrared camera. The infrared detector has a usable area of 128 × 128 pixels, measuring up to 16 384 interferograms simultaneously. Imaging Fourier transform spectrometers impose a number of challenges with respect to instrument calibration and algorithm development. The optical setup with extremely high optical throughput requires the development of new methods and algorithms for spectral and radiometric calibration. Due to the vast amount of data there is a high demand for scientifically intelligent optimisation of the data processing. This paper outlines the characterisation and processing steps required for the generation of radiometrically and spectrally calibrated spectra. Methods for performance optimisation of the processing algorithm are presented. The performance of the data processing and the quality of the calibrated spectra are demonstrated for measurements collected during the first deployments of GLORIA on aircraft.

  2. Radiometric cross calibration of Landsat 8 Operational Land Imager (OLI) and Landsat 7 Enhanced Thematic Mapper Plus (ETM+)

    Science.gov (United States)

    Mishra, Nischal; Haque, Md. Obaidul; Leigh, Larry; Aaron, David; Helder, Dennis; Markham, Brian L

    2014-01-01

    This study evaluates the radiometric consistency between Landsat-8 Operational Land Imager (OLI) and Landsat 7 Enhanced Thematic Mapper Plus (ETM+) using cross calibration techniques. Two approaches are used, one based on cross calibration between the two sensors using simultaneous image pairs, acquired during an underfly event on 29–30 March 2013. The other approach is based on using time series of image statistics acquired by these two sensors over the Libya 4 pseudo invariant calibration site (PICS) (+28.55°N, +23.39°E). Analyses from these approaches show that the reflectance calibration of OLI is generally within ±3% of the ETM+ radiance calibration for all the reflective bands from visible to short wave infrared regions when the ChKur solar spectrum is used to convert the ETM+ radiance to reflectance. Similar results are obtained comparing the OLI radiance calibration directly with the ETM+ radiance calibration and the results in these two different physical units (radiance and reflectance) agree to within ±2% for all the analogous bands. These results will also be useful to tie all the Landsat heritage sensors from Landsat 1 MultiSpectral Scanner (MSS) through Landsat-8 OLI to a consistent radiometric scale.

  3. Imager-to-Radiometer In-flight Cross Calibration: RSP Radiometric Comparison with Airborne and Satellite Sensors

    Science.gov (United States)

    McCorkel, Joel; Cairns, Brian; Wasilewski, Andrzej

    2016-01-01

    This work develops a method to compare the radiometric calibration between a radiometer and imagers hosted on aircraft and satellites. The radiometer is the airborne Research Scanning Polarimeter (RSP), which takes multi-angle, photo-polarimetric measurements in several spectral channels. The RSP measurements used in this work were coincident with measurements made by the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS), which was on the same aircraft. These airborne measurements were also coincident with an overpass of the Landsat 8 Operational Land Imager (OLI). First we compare the RSP and OLI radiance measurements to AVIRIS since the spectral response of the multispectral instruments can be used to synthesize a spectrally equivalent signal from the imaging spectrometer data. We then explore a method that uses AVIRIS as a transfer between RSP and OLI to show that radiometric traceability of a satellite-based imager can be used to calibrate a radiometer despite differences in spectral channel sensitivities. This calibration transfer shows agreement within the uncertainty of both the various instruments for most spectral channels.

  4. Liquid Crystals

    Science.gov (United States)

    1990-01-01

    Thermochromic liquid crystals, or TLCs, are a type of liquid crystals that react to changes in temperature by changing color. The Hallcrest/NASA collaboration involved development of a new way to visualize boundary layer transition in flight and in wind tunnel testing of aircraft wing and body surfaces. TLCs offered a new and potentially better method of visualizing the boundary layer transition in flight. Hallcrest provided a liquid crystal formulation technique that afforded great control over the sensitivity of the liquid crystals to varying conditions. Method is of great use to industry, government and universities for aerodynamic and hydrodynamic testing. Company's principal line is temperature indicating devices for industrial use, such as non-destructive testing and flaw detection in electric/electronic systems, medical application, such as diagnostic systems, for retail sale, such as room, refrigerator, baby bath and aquarium thermometers, and for advertising and promotion specials. Additionally, Hallcrest manufactures TLC mixtures for cosmetic applications, and liquid crystal battery tester for Duracell batteries.

  5. Radiometric parameters in freshwater samples of Centro Experimental Aramar (CTMSP/Brazil)

    Energy Technology Data Exchange (ETDEWEB)

    Moraes, Marco Antonio P.V. [Laboratorio Radioecologico (LARE), Ipero, SP (Brazil). Dept. de Seguranca Nuclear; Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    Experimental results are described obtained with gamma spectrometry, alpha and beta gross counts, liquid scintillation and fluorometry techniques for the measurement of background radiation in surface water samples, collected in Centro Experimental Aramar and surroundings, from 1988 to 2009. The estimated average background radiation concentrations in water samples in this region are low, related to the low level detection limits of the techniques, and indicates good water quality parameters, and low interference in the environment in Centro Experimental Aramar and region. (author)

  6. Liquid acrobatics

    CERN Document Server

    Bird, James C

    2008-01-01

    We experiment with injecting a continuous stream of gas into a shallow liquid, similar to how one might blow into a straw placed at the bottom of a near-empty drink. By varying the angle of the straw (here a metal needle), we observe a variety of dynamics, which we film using a high-speed camera. Most noteworthy is an intermediate regime in which cyclical jets erupt from the air-liquid interface and breakup into air-born droplets. These droplets trace out a parabolic trajectory and bounce on the air-liquid interface before eventually coalescing. The shape of each jet, as well as the time between jets, is remarkably similar and leads to droplets with nearly identical trajectories. The following article accompanies the linked fluid dynamics video submitted to the Gallery of Fluid Motion in 2008.

  7. Macromolecular liquids

    Energy Technology Data Exchange (ETDEWEB)

    Safinya, C.R.; Safran, S.A. (Exxon Research and Engineering Co., Annandale, NJ (US)); Pincus, P.A. (Univ. of California at Santa Barbara, Santa Barbara, CA (US))

    1990-01-01

    Liquids include a broad range of material systems which are of high scientific and technological interest. Generally speaking, these are partially ordered or disordered phases where the individual molecular species have organized themselves on length scales which are larger than simple fluids, typically between 10 Angstroms and several microns. The specific systems reported on in this book include membranes, microemulsions, micelles, liquid crystals, colloidal suspensions, and polymers. They have a major impact on a broad spectrum of technological industries such as displays, plastics, soap and detergents, chemicals and petroleum, and pharmaceuticals.

  8. CSP parabolic trough and power tower performance analysis through the Southern African universities radiometric network (SAURAN) data

    Science.gov (United States)

    Pidaparthi, A. S.; Dall, E. P.; Hoffmann, J. E.; Dinter, F.

    2016-05-01

    The objective of this paper is to analyse the performance of parabolic trough and power tower technologies by selecting two radiometric stations in different geographic locations, with approximately equal annual direct normal irradiance (DNI) values, but with different monthly DNI distributions. The two stations chosen for this study are situated at the University of Free State, Bloemfontein, Free State Province and in Vanrhynsdorp, Western Cape Province. The annual measured DNI values for both these locations in South Africa are in the range of 2500-2700 kWh/m2. The comparison between the different monthly DNI distributions of these selected sites includes an assessment of annual hourly data in order to study the performance analysis of the most mature concentrating solar power (CSP) technologies, namely parabolic trough and power tower plants. The weather data has been obtained from the Southern African Universities Radiometric Network (SAURAN). A comparison between the different monthly DNI distributions of these selected sites includes the assessment of hourly data. Selection of these radiometric stations has also been done on the basis that they have been operational for at least one year. The first year that most SAURAN stations have been online for at least one year is 2014, thus data from this year has been considered. The annual performance analysis shows that parabolic trough plants have a higher energy yield in Vanrhynsdorp while power tower plants seem to be more suitable for Bloemfontein. Power tower plants in both the locations have a higher annual energy yield when compared with parabolic trough plants. A parabolic trough power plant in Vanrhynsdorp in the Western Cape Province has very low monthly electricity generation in the winter months of May, June, July and August. This is partly due to the higher cosine losses in the parabolic trough `one-axis' tracking systems and lower DNI values in the winter months. However, a power tower plant in

  9. Liquid Marbles

    KAUST Repository

    Khalil, Kareem

    2012-12-01

    Granulation, the process of formation of granules from a combination of base powders and binder liquids, has been a subject of research for almost 50 years, studied extensively for its vast applications, primarily to the pharmaceutical industry sector. The principal aim of granulation is to form granules comprised of the active pharmaceutical ingredients (API’s), which have more desirable handling and flowability properties than raw powders. It is also essential to ensure an even distribution of active ingredients within a tablet with the goal of achieving time‐controlled release of drugs. Due to the product‐specific nature of the industry, however, data is largely empirical [1]. For example, the raw powders used can vary in size by two orders of magnitude with narrow or broad size distributions. The physical properties of the binder liquids can also vary significantly depending on the powder properties and required granule size. Some significant progress has been made to better our understanding of the overall granulation process [1] and it is widely accepted that the initial nucleation / wetting stage, when the binder liquid first wets the powders, is key to the whole process. As such, many experimental studies have been conducted in attempt to elucidate the physics of this first stage [1], with two main mechanisms being observed – classified by Ivenson [1] as the “Traditional description” and the “Modern Approach”. See Figure 1 for a graphical definition of these two mechanisms. Recent studies have focused on the latter approach [1] and a new, exciting development in this field is the Liquid Marble. This interesting formation occurs when a liquid droplet interacts with a hydrophobic (or superhydrophobic) powder. The droplet can become encased in the powder, which essentially provides a protective “shell” or “jacket” for the liquid inside [2]. The liquid inside is then isolated from contact with other solids or liquids and has some

  10. Comparison of radiometric scaling laws and detailed wave-optics simulations for designing ground-based laser satellite-illumination and receiver systems

    Science.gov (United States)

    Bush, Keith A.

    2002-12-01

    Ground-based optical transmitter and receiver systems designed for active imaging, active tracking and laser ranging of satellites in Earth orbit are very sensitive to physical conditions limiting the radiometric returns for achieving these measurements. The initial design of these systems is often based on simple radiometric scaling laws that provide estimates of average radiometric returns and are derived from experimental data or from more complex theoretical calculations. While these laws are quite useful, it is often easy to lose sight of the initial assumptions made in their formulation, and hence, the limits of their accuracy for designing certain systems. The objective of this paper is to review some of the commonly used radiometric scaling laws for active systems and to establish guidelines for their use based on comparisons of their predictions with results from detailed wave-optics simulations for different system design requirements and physical conditions. The combined effects of laser and transmitter beam parameters, wave-front aberrations, atmospheric turbulence, and satellite optical cross-section are considered.

  11. Revisiting the paper “Using radiometric surface temperature for surface energy flux estimation in Mediterranean drylands from a two-source perspective”

    DEFF Research Database (Denmark)

    Kustas, William P.; Nieto, Hector; Morillas, Laura

    2016-01-01

    The recent paper by Morillas et al. [Morillas, L. et al. Using radiometric surface temperature for surface energy flux estimation in Mediterranean drylands from a two-source perspective, Remote Sens. Environ. 136, 234–246, 2013] evaluates the two-source model (TSM) of Norman et al. (1995) with re...

  12. A Sounding Rocket Mission Concept to Acquire High-Resolution Radiometric Spectra Spanning the 9 nm - 31 nm Wavelength Range

    Science.gov (United States)

    Krause, L. Habash; Cirtain, Jonathan; McGuirck, Michael; Pavelitz, Steven; Weber, Ed.; Winebarger, Amy

    2012-01-01

    When studying Solar Extreme Ultraviolet (EUV) emissions, both single-wavelength, two- dimensional (2D) spectroheliograms and multi-wavelength, one-dimensional (1D) line spectra are important, especially for a thorough understanding of the complex processes in the solar magnetized plasma from the base of the chromosphere through the corona. 2D image data are required for a detailed study of spatial structures, whereas radiometric (i.e., spectral) data provide information on relevant atomic excitation/ionization state densities (and thus temperature). Using both imaging and radiometric techniques, several satellite missions presently study solar dynamics in the EUV, including the Solar Dynamics Observatory (SDO), Hinode, and the Solar-Terrestrial Relations Observatory (STEREO). The EUV wavelengths of interest typically span 9 nm to 31 nm, with the shorter wavelengths being associated with the hottest features (e.g., intense flares and bright points) and the longer wavelengths associated with cooler features (e.g., coronal holes and filaments). Because the optical components of satellite instruments degrade over time, it is not uncommon to conduct sounding rocket underflights for calibration purposes. The authors have designed a radiometric sounding rocket payload that could serve as both a calibration underflight for and a complementary scientific mission to the upcoming Solar Ultraviolet Imager (SUVI) mission aboard the GOES-R satellite (scheduled for a 2015 launch). The challenge to provide quality radiometric line spectra over the 9-31 nm range covered by SUVI was driven by the multilayer coatings required to make the optical components, including mirrors and gratings, reflective over the entire range. Typically, these multilayers provide useful EUV reflectances over bandwidths of a few nm. Our solution to this problem was to employ a three-telescope system in which the optical components were coated with multilayers that spanned three wavelength ranges to cover

  13. Correlation of VLF-EM Data with Radiometric Measurements: Implications for Uranium Exploration around Beldih, South Purulia Shear Zone, India

    Directory of Open Access Journals (Sweden)

    Saurabh Mittal

    2014-01-01

    Full Text Available This study is an attempt to correlate VLF-EM data with the radiometric measurements to decipher the subsurface structure and to locate uranium mineralization in the shear zone. The study area is around Beldih mine which is an open cast apatite mine located on the South Purulia Shear Zone. VLF method has been applied to map the structure and the presence of radioactive minerals has been delineated by the detection of high α and γ counts with respect to the background radiations. High radiation counts and high surface γ activity are found just above the higher apparent current-density zones in all the profiles studied, at various locations, indicating uranium and/or thorium mineralization as well as good correlation between these techniques.

  14. Comparison of global irradiance measurements of the official Spanish radiometric network for 2006 with satellite estimated data

    Directory of Open Access Journals (Sweden)

    J. M. Sancho

    2011-01-01

    Full Text Available The monthly average values of daily global irradiance measured in broadband at 40 stations of the National Radiometric Network of the Spanish Meteorological Agency have been compared with the monthly values of SIS (Surface Incoming Shortwave radiation of the Climate Monitoring-Satellite Application Facility for 2006. It is calculated by the data from the instrument Spinning Enhanced Visible and Infrared Imager of the Meteosat Second Generation satellite and of the Advanced Very High Resolution Radiometer of the NOAA polar satellites. The results show a great similarity between the data from both sources of information, and the discrepancies found are around 5%. The aim of such a comparison is to evaluate the suitability of the use of the SIS data for the elaboration of an atlas of solar irradiance available in Spain.

  15. Surface aerosol radiative forcing derived from collocated ground-based radiometric observations during PRIDE, SAFARI, and ACE-Asia.

    Science.gov (United States)

    Hansell, Richard A; Tsay, Si-Chee; Ji, Qiang; Liou, K N; Ou, Szu-Cheng

    2003-09-20

    An approach is presented to estimate the surface aerosol radiative forcing by use of collocated cloud-screened narrowband spectral and thermal-offset-corrected radiometric observations during the Puerto Rico Dust Experiment 2000, South African Fire Atmosphere Research Initiative (SAFARI) 2000, and Aerosol Characterization Experiment-Asia 2001. We show that aerosol optical depths from the Multiple-Filter Rotating Shadowband Radiometer data match closely with those from the Cimel sunphotometer data for two SAFARI-2000 dates. The observed aerosol radiative forcings were interpreted on the basis of results from the Fu-Liou radiative transfer model, and, in some cases, cross checked with satellite-derived forcing parameters. Values of the aerosol radiative forcing and forcing efficiency, which quantifies the sensitivity of the surface fluxes to the aerosol optical depth, were generated on the basis of a differential technique for all three campaigns, and their scientific significance is discussed.

  16. Critical comparison of radiometric and mass spectrometric methods for the determination of radionuclides in environmental, biological and nuclear waste samples.

    Science.gov (United States)

    Hou, Xiaolin; Roos, Per

    2008-02-11

    The radiometric methods, alpha (alpha)-, beta (beta)-, gamma (gamma)-spectrometry, and mass spectrometric methods, inductively coupled plasma mass spectrometry, accelerator mass spectrometry, thermal ionization mass spectrometry, resonance ionization mass spectrometry, secondary ion mass spectrometry, and glow discharge mass spectrometry are reviewed for the determination of radionuclides. These methods are critically compared for the determination of long-lived radionuclides important for radiation protection, decommissioning of nuclear facilities, repository of nuclear waste, tracer application in the environmental and biological researches, these radionuclides include (3)H, (14)C, (36)Cl, (41)Ca, (59,63)Ni, (89,90)Sr, (99)Tc, (129)I, (135,137)Cs, (210)Pb, (226,228)Ra, (237)Np, (241)Am, and isotopes of thorium, uranium and plutonium. The application of on-line methods (flow injection/sequential injection) for separation of radionuclides and automated determination of radionuclides is also discussed.

  17. 传感器交叉辐射定标综述%Review of radiometric cross-calibration

    Institute of Scientific and Technical Information of China (English)

    高彩霞; 姜小光; 马灵玲; 霍红元

    2013-01-01

    With the development of quantitative remote sensing, interest in the radiometric calibration aspects of terrestrial remote sensing has been on the rise, and significant resources are being devoted to the relevant areas of research and development. The radiometric calibration of those sensors is a contributing factor to the success of application of remote sensing data. The calibration of sensors has relied on the preflight laboratory work as well as on in-flight techniques. At present, three kinds of in-flight radiometric calibration methods have been developed and widely used, namely, on-board calibration, in-situ calibration and cross-calibration. On-board calibrators, such as solar diffuser (SD) and solar diffuser stability monitor (SDSM) , can be used for operational calibration; however, some satellites are not equipped with these due to power, weight, and space restrictions. In order to compensate for the limitations of on-board calibration systems, many methods have been proposed and used for in-flight radiometric calibration, such as in-situ calibration and cross-calibration. The problem with in-situ calibration is that it could be labor intensive, costly and time consuming. This typically limits the number of calibrations that can be performed. Cross-calibration is an alternative and potentially easier technique that can be used to acquire post-launch calibration coefficients. In comparison to in-situ calibration, cross-calibration can circumvent the strict requirements of atmospheric and surface variables; it is a cost-effective and convenient mean of calibration without the need of accurate synchronous in-situ measurements, compensating for the deficiencies of in-situ calibration. To date, many cross-calibration methods have been proposed with the same goal but different application conditions, advantages and limitations. Therefore, this paper aims to review these cross-calibration methods and to provide technical assistance for in-flight calibration

  18. Radiometric dating of the Earlier Stone Age sequence in excavation I at Wonderwerk Cave, South Africa: preliminary results.

    Science.gov (United States)

    Chazan, Michael; Ron, Hagai; Matmon, Ari; Porat, Naomi; Goldberg, Paul; Yates, Royden; Avery, Margaret; Sumner, Alexandra; Horwitz, Liora Kolska

    2008-07-01

    We present here the results of 44 paleomagnetic measurements, and single cosmogenic burial and optically stimulated luminescence ages for the Earlier Stone Age deposits from Wonderwerk Cave, Northern Cape, South Africa. The resulting paleomagnetic sequence: N>R>N>R>N constrains the Earlier Stone Age strata in this part of the site to between approximately 0.78-1.96 Ma. A single cosmogenic date of approximately 2.0 Ma from the base of the section offers some corroboration for the paleomagnetic sequence. Preliminary results indicate that the small lithic assemblage from the basal stratum may contain an Oldowan facies. This is overlain by several strata containing Acheulean industries. The preliminary radiometric dates reported here place the onset of the Acheulean at this site to approximately 1.6 Ma, which is roughly contemporaneous with that of East Africa.

  19. Radiometric Compensation of Images Projected on Non-White Surfaces by Exploiting Chromatic Adaptation and Perceptual Anchoring.

    Science.gov (United States)

    Huang, Tai-Hsiang; Wang, Ting-Chun; Chen, Homer H

    2017-01-01

    Flat surfaces in our living environment to be used as replacements of a projection screen are not necessarily white. We propose a perceptual radiometric compensation method to counteract the effect of color projection surfaces on image appearance. It reduces color clipping while preserving the hue and brightness of images based on the anchoring property of human visual system. In addition, it considers the effect of chromatic adaptation on perceptual image quality and fixes the color distortion caused by non-white projection surfaces by properly shifting the color of the image pixels toward the complementary color of the projection surface. User ratings show that our method outperforms the existing methods in 974 out of 1020 subjective tests.

  20. APPLICATION OF MILLIMETER WAVE′S RADIOMETRIC SYSTEM FOR DETECTION OF MALIGNANT NEW GROWTHS OF MAMMARY GLANDS

    Directory of Open Access Journals (Sweden)

    V. V. Murav’iov

    2014-01-01

    Full Text Available Developed and investigated radiometric system EHF (extremely high frequency range for the diagnosis of tissue samples affected by carcinoma. EHF system are significantly higher than in the possibility of identifying a lower frequency range, as in UHF band (UHF band and UHF (ultra high frequency resolution of 1-3 mm are impossible. It was established that the affected carcinoma tissue samples are 3 dB lower transmittance compared to unaffected tissues. Analysis of the dependency of the harmonic components of the modulation signal passing through the examined tissue samples shows dramatic difference in the behavior of the harmonic components of the frequency domain. This phenomenon appears to altered tissue the presence of slumps that due to the interaction of electromagnetic waves with the tissue samples may be explained by the so-called stochastic resonance effect. 

  1. Tectonic structure and post-Hercynian evolution of the Serre, Calabrian Arc, southern Italy: Geological, petrological and radiometric evidences

    Science.gov (United States)

    Moro, Aldo Del; Paglionico, Antonio; Piccarreta, Giuseppe; Rottura, Alessandro

    1986-04-01

    Conflicting opinions exist concerning the structure and the post-Hercynian evolution of the Serre. The present paper deals with these topics on the basis of new geological, petrological and radiometric evidence. The composition of the so-called Stilo and Polia-Copanello units has been redefined. The above domains—former sections of upper and lower Palaeozoic continental crust respectively—came into contact, due to transcurrent movements 130-140 Ma ago. A significant vertical component during the transcurrent movements, probably, exhumed the former section of lower crust. The above domains, juxtaposed, were successively involved as a single kinematic body in the Alpine orogenesis. The results enable us to make inferences for the Calabrian Arc evolution and call attention to similarities between an Austro-Alpine element (Stilo + Polia-Copanello) of the Calabrian chain and a South-Alpine sector of the Alps (Ivrea + Ceneri zones).

  2. Diabatic initialization for improvement in the tropical analysis of divergence and moisture using satellite radiometric imagery data

    Science.gov (United States)

    Kasahara, Akira; Mizzi, Arthur P.; Donner, Leo J.

    1994-05-01

    To improve the quality of horizontal divergence and moisture analyses in the tropics, a diabatic initialization scheme is developed to incorporate information on convective activity and the proxy data of precipitation obtained from satellite radiometric imagery data. The tropical precipitation rates are estimated by developing a relationship between the pentad precipitation data of the Global Precipitation Climatology Project with daily outgoing longwave radiation data. The tropical belt from 35°S to 25°N (for January 1988) is divided into 3 parts: convective, convective fringe, and downward-motion (clear-air) areas. In the convective region, the algorithm adjusts the horizontal divergence and humidity fields such that a version of the Kuo cumulus parameterization will yield the precipitation rates closest to the proxy data. The temperature in the planetary boundary layer is also adjusted, if necessary, to ensure the initiation of cumulus convection. In the downward-motion region, the divergence field is adjusted to yield descending motion expected from the thermodynamic balance between radiative cooling and adiabatic warming. In the convective fringe region, where convective criteria are not met, the divergence field is adjusted only to satisfy the global conservation of divergence. The humidity field is left intact in both the downward-motion and convective fringe regions. This adjustment scheme will ameliorate problems associated with spinup of precipitation in a numerical prediction model with the same cumulus parameterization as used in the initialization. This initialization scheme may be used as a method of quality control for first-guess fields in four-dimensional data assimilation by means of satellite radiometric imagery data.

  3. Evaluation of radiometric faecal culture and direct PCR on pooled faeces for detection of Mycobacterium avium subsp. paratuberculosis in cattle.

    Science.gov (United States)

    Eamens, Graeme J; Whittington, Richard J; Turner, Mark J; Austin, Susan L; Fell, Shayne A; Marsh, Ian B

    2007-11-15

    Dilution rates for pooled faecal culture (PFC) and direct IS900 polymerase chain reaction (D-PCR) tests were evaluated on faecal samples from infected cows mixed with uninfected faeces in dilutions from 1 in 5 to 1 in 50. PFC was performed by radiometric culture, with confirmation by IS900 PCR and restriction endonuclease analysis (PCR/REA) on growth, and by mycobactin dependency testing on solid medium. Using 37 culture positive faecal samples from 12 subclinical cows, 83.8% and 94.6% of samples were confirmed positive in the PFC assay at dilutions of 1 in 50 and 1 in 30, respectively. Lower dilutions (1 in 5 to 1 in 20) provided only marginally better sensitivity, and confirmation of PFC growth by PCR/REA was significantly more sensitive than mycobactin dependency. D-PCR had significantly lower sensitivity than PFC confirmed by PCR/REA, with pools of 1 in 50, 30, 10 and 5 yielding positive results in 64.9%, 70.3%, 78.4% and 83.8% of samples, respectively. Cattle considered to be shedding 1.5 x 10(6) viable M. avium subsp. paratuberculosis (Map)/g faeces (on the basis of estimated losses in processing and growth rates in radiometric broth) were positive at dilutions up to 1 in 50 in the PFC and D-PCR. Those shedding 5 x 10(5) viable Map/g were positive in the PFC at dilutions up to 1 in 40, but required a 1 in 10 dilution or less for D-PCR. The results suggest that for cattle shedding relatively high concentrations of Map in faeces (>2 x 10(5) viable Map/g), maximal dilutions of 1 in 30 for PFC and 1 in 10 for D-PCR would be applicable.

  4. Analysis of the radiometric survey during the Argonauta reactor operation; Analise do levantamento radiometrico durante operacao do reator Argonauta

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Eara de S.L.; Cardozo, Katia K.M.; Silva, Joao Carlos P.; Santos, Joao Regis dos, E-mail: esluz@ien.gov.br, E-mail: cardozo@ien.gov.br, E-mail: jcarlos@ien.gov.br, E-mail: regis@ien.gov.br [Instituto de Engenharia Nuclear (CNEN-IEN/RJ), Rio de Janeiro - RJ (Brazil)

    2013-07-01

    The Argonaut reactor at the Institute of Nuclear Engineering-IEN/CNEN, operates normally, the powers between 1.7 and 340 W on neutrongraphy procedures, production of radionuclides and experimental reactor physics lessons to postgraduate courses. The doses from neutrons and gamma radiation are measured when the reactor is critical, inside the reactor hall and surrounding regions. A study of the data obtained was performed to evaluate the daily need of this survey in the reactor hall. Taking into account the principle ALARA, which aims to optimize and minimize the dose received by the individual, we propose, in this work, through an analysis of the acquired data in occupational radiometric surveys, a reformulation of the area monitoring routine practiced by the team of radiological protection of the Institute of Nuclear Engineering - IEN/CNEN-RJ, whereas other monitoring routines regarding the radiological protection are also applied in the routine of the reactor. The operations under review occurred with the reactor operating 340 W power at intervals of 60, 120 and 180 minutes, in monitoring points in controlled areas, supervised and free. The results showed significant dose values in the output of the J-Channel 9 when the operation occurs with this open. With 180 minutes of operation, the measured values of dose rate were lower than the values at 60 min and 120 operations min. At the point in the supervised area, offsite to the reactor hall, situated in the direction of the J-Channel 9, the value reduces more than 14% in any operating time in relation to the dose rate measured at the point opposite the canal. There is a 50% reduction in the dose rates for operations with and J-9 closed. The results suggest a new frequency of radiometric survey whose mode of operation is maintained in similar conditions, since combined with other relevant practices of radiation protection.

  5. Radiometric cross-calibration of the Terra MODIS and Landsat 7 ETM+ using an invariant desert site

    Science.gov (United States)

    Choi, T.; Angal, A.; Chander, G.; Xiong, X.

    2008-01-01

    A methodology for long-term radiometric cross-calibration between the Terra Moderate Resolution Imaging Spectroradiometer (MODIS) and Landsat 7 (L7) Enhanced Thematic Mapper Plus (ETM+) sensors was developed. The approach involves calibration of near-simultaneous surface observations between 2000 and 2007. Fifty-seven cloud-free image pairs were carefully selected over the Libyan desert for this study. The Libyan desert site (+28.55??, +23.39??), located in northern Africa, is a high reflectance site with high spatial, spectral, and temporal uniformity. Because the test site covers about 12 kmx13 km, accurate geometric preprocessing is required to match the footprint size between the two sensors to avoid uncertainties due to residual image misregistration. MODIS Level IB radiometrically corrected products were reprojected to the corresponding ETM+ image's Universal Transverse Mercator (UTM) grid projection. The 30 m pixels from the ETM+ images were aggregated to match the MODIS spatial resolution (250 m in Bands 1 and 2, or 500 m in Bands 3 to 7). The image data from both sensors were converted to absolute units of at-sensor radiance and top-ofatmosphere (TOA) reflectance for the spectrally matching band pairs. For each band pair, a set of fitted coefficients (slope and offset) is provided to quantify the relationships between the testing sensors. This work focuses on long-term stability and correlation of the Terra MODIS and L7 ETM+ sensors using absolute calibration results over the entire mission of the two sensors. Possible uncertainties are also discussed such as spectral differences in matching band pairs, solar zenith angle change during a collection, and differences in solar irradiance models.

  6. Multispectral Radiometric Analysis of Façades to Detect Pathologies from Active and Passive Remote Sensing

    Directory of Open Access Journals (Sweden)

    Susana Del Pozo

    2016-01-01

    Full Text Available This paper presents a radiometric study to recognize pathologies in façades of historical buildings by using two different remote sensing technologies covering part of the visible and very near infrared spectrum (530–905 nm. Building materials deteriorate over the years due to different extrinsic and intrinsic agents, so assessing these affections in a non-invasive way is crucial to help preserve them since in many cases they are valuable and some have been declared monuments of cultural interest. For the investigation, passive and active remote acquisition systems were applied operating at different wavelengths. A 6-band Mini-MCA multispectral camera (530–801 nm and a FARO Focus3D terrestrial laser scanner (905 nm were used with the dual purpose of detecting different materials and damages on building façades as well as determining which acquisition system and spectral range is more suitable for this kind of studies. The laser scan points were used as base to create orthoimages, the input of the two different classification processes performed. The set of all orthoimages from both sensors was classified under supervision. Furthermore, orthoimages from each individual sensor were automatically classified to compare results from each sensor with the reference supervised classification. Higher overall accuracy with the FARO Focus3D, 74.39%, was obtained with respect to the Mini MCA6, 66.04%. Finally, after applying the radiometric calibration, a minimum improvement of 24% in the image classification results was obtained in terms of overall accuracy.

  7. Lunar Spectral Irradiance and Radiance (LUSI): New Instrumentation to Characterize the Moon as a Space-Based Radiometric Standard.

    Science.gov (United States)

    Smith, Allan W; Lorentz, Steven R; Stone, Thomas C; Datla, Raju V

    2012-01-01

    The need to understand and monitor climate change has led to proposed radiometric accuracy requirements for space-based remote sensing instruments that are very stringent and currently outside the capabilities of many Earth orbiting instruments. A major problem is quantifying changes in sensor performance that occur from launch and during the mission. To address this problem on-orbit calibrators and monitors have been developed, but they too can suffer changes from launch and the harsh space environment. One solution is to use the Moon as a calibration reference source. Already the Moon has been used to remove post-launch drift and to cross-calibrate different instruments, but further work is needed to develop a new model with low absolute uncertainties capable of climate-quality absolute calibration of Earth observing instruments on orbit. To this end, we are proposing an Earth-based instrument suite to measure the absolute lunar spectral irradiance to an uncertainty(1) of 0.5 % (k=1) over the spectral range from 320 nm to 2500 nm with a spectral resolution of approximately 0.3 %. Absolute measurements of lunar radiance will also be acquired to facilitate calibration of high spatial resolution sensors. The instruments will be deployed at high elevation astronomical observatories and flown on high-altitude balloons in order to mitigate the effects of the Earth's atmosphere on the lunar observations. Periodic calibrations using instrumentation and techniques available from NIST will ensure traceability to the International System of Units (SI) and low absolute radiometric uncertainties.

  8. Liquid/liquid heat exchanger

    Science.gov (United States)

    Miller, C. G.

    1980-01-01

    Conceptual design for heat exchanger, utilizing two immiscible liquids with dissimilar specific gravities in direct contact, is more efficient mechanism of heat transfer than conventional heat exchangers with walls or membranes. Concept could be adapted for collection of heat from solar or geothermal sources.

  9. Solar Tower Experiments for Radiometric Calibration and Validation of Infrared Imaging Assets and Analysis Tools for Entry Aero-Heating Measurements

    Science.gov (United States)

    Splinter, Scott C.; Daryabeigi, Kamran; Horvath, Thomas J.; Mercer, David C.; Ghanbari, Cheryl M.; Ross, Martin N.; Tietjen, Alan; Schwartz, Richard J.

    2008-01-01

    The NASA Engineering and Safety Center sponsored Hypersonic Thermodynamic Infrared Measurements assessment team has a task to perform radiometric calibration and validation of land-based and airborne infrared imaging assets and tools for remote thermographic imaging. The IR assets and tools will be used for thermographic imaging of the Space Shuttle Orbiter during entry aero-heating to provide flight boundary layer transition thermography data that could be utilized for calibration and validation of empirical and theoretical aero-heating tools. A series of tests at the Sandia National Laboratories National Solar Thermal Test Facility were designed for this task where reflected solar radiation from a field of heliostats was used to heat a 4 foot by 4 foot test panel consisting of LI 900 ceramic tiles located on top of the 200 foot tall Solar Tower. The test panel provided an Orbiter-like entry temperature for the purposes of radiometric calibration and validation. The Solar Tower provided an ideal test bed for this series of radiometric calibration and validation tests because it had the potential to rapidly heat the large test panel to spatially uniform and non-uniform elevated temperatures. Also, the unsheltered-open-air environment of the Solar Tower was conducive to obtaining unobstructed radiometric data by land-based and airborne IR imaging assets. Various thermocouples installed on the test panel and an infrared imager located in close proximity to the test panel were used to obtain surface temperature measurements for evaluation and calibration of the radiometric data from the infrared imaging assets. The overall test environment, test article, test approach, and typical test results are discussed.

  10. Chiral liquids

    Directory of Open Access Journals (Sweden)

    Zakharov V.I.

    2015-01-01

    Full Text Available We review briefly properties of chiral liquids, or liquids with massless fermionic constituents. We concentrate on three effects, namely, the low ratio of viscosity η to entropy density s, chiral magnetic and vortical effects. We sketch standard derivations of these effects in the hydrodynamic approximation and then concentrate on possibile unifying approach which is based on consideration of the (anomalously conserved axial current. The point is that the conservation of chirality is specific for the microscopic, field-theoretic description of massless fermions and their interactions. On the macroscopic side, the standard hydrodynamic equations are not consistent, generally speaking, with conservation of a helical macroscopic motion. Imposing extra constraints on the hydrodynamics might resolve this “clash-of-symmetries” paradox.

  11. Liquid helium

    CERN Document Server

    Atkins, K R

    1959-01-01

    Originally published in 1959 as part of the Cambridge Monographs on Physics series, this book addresses liquid helium from the dual perspectives of statistical mechanics and hydrodynamics. Atkins looks at both Helium Three and Helium Four, as well as the properties of a combination of the two isotopes. This book will be of value to anyone with an interest in the history of science and the study of one of the universe's most fundamental elements.

  12. Pump for Saturated Liquids

    Science.gov (United States)

    Elliott, D. G.

    1986-01-01

    Boiling liquids pumped by device based on proven components. Expanding saturated liquid in nozzle and diverting its phases along separate paths in liquid/vapor separator raises pressure of liquid. Liquid cooled in process. Pump makes it unnecessary to pressurize cryogenic liquids in order to pump them. Problems of introducing noncondensable pressurizing gas avoided.

  13. Liquid Ventilation

    Directory of Open Access Journals (Sweden)

    Peter N Cox

    1996-01-01

    Full Text Available There has been a recent explosion of interest in the use of liquid ventilation. Over time humans have lost the physiological attributes necessary for respiration in water. However, perfluorocarbons have high solubilities for oxygen and carbon dioxide, as well as a low surface tension. These characteristics allow them to be used as a medium to assist gas exchange and recruit atelectatic-dependent lung zones in respiratory distress syndrome. Current trials may prove perfluorocarbon to be a useful adjunct in lung protective strategies in respiratory distress syndrome.

  14. [Process analysis for levulinic acid generated in waste wood liquefaction by non-development thin-layer chromatography based on oblique projection].

    Science.gov (United States)

    Su, Hui; Ge, Jun; Fang, Feng; Yao, Zhixiang; Song, Guangjun

    2014-01-01

    A rapid and quantitative method is presented for multi-component process analysis, based on multi-wavelength thin-layer chromatography (TLC) scanning but without the routine development. The samples from the waste wood liquefaction process are applied on silica plates, and just the last sample of spot need to be developed for getting separated spectra. These spectra are divided into two parts of production (levulinic acid) and background, respectively, to build an oblique projection operator. The other process samples do not need to be developed repeatedly, and are scanned to collect hybrid spectra immediately. The pure production spectrum can be separated from the process spectrum by the oblique projection algorithms to realize the production quantification. It was showed that the relative errors between the determination results by this method and those by high performance liquid chromatography (HPLC) were less than 3.27%, and so the consistency is perfect.

  15. Combined high-resolution aeromagnetic and radiometric mapping of uranium mineralization and tectonic settings in Northeastern Nigeria

    Science.gov (United States)

    Adepelumi, A. A.; Falade, A. H.

    2017-09-01

    Geological lineaments, depths to the basement, uranium concentrations, and remobilization in parts of the Upper Benue Trough, covering about 55 × 55 km2 (longitudes 11°30'-12°00'E and 10°30'-10°30'N), Northeastern Nigeria were investigated using integrated High-Resolution Aeromagnetic Data (HRAD) and radiometric data. This was with a view to identifying the potential zones of uranium occurrence in the area. The HRAD was processed to accentuate anomalies of interest and depths estimate of 150-1941 m were obtained from source parameter imaging technique. The results from the superposition of the horizontal gradient magnitude, analytical signal amplitude, first vertical derivative, and 3D Euler solutions of the HRAD revealed that the study area was dissected by linear structures that trend ENE-WSW, NE-SW, E-W, NNE-SSW, WNW-ESE, and NW-SE; among which the ENE-WSW and NE-SW trends dominated. Analyses of radiometric data showed that uranium ores in the study area were possibly remobilized epigenetically from the granitic rocks, and were later deposited into sedimentary rocks (Bima formation). Burashika group (Bongna hills) and Wawa area of the study area showed vein-type deposits, while the anatectic migmatite in the northeastern region and the uranium rich Bima formation showed both fault/fracture and contact types of deposition. It was also observed the northwesterly and southeasterly, dominant dip direction, dipping faults dip in the same direction as the paleocurrent direction (direction of depositions of sediments), and trend in a direction perpendicular to the hypothetical direction of uranium deposition. The study concluded that the studied area is dissected by several linear structures and the studied area possibly contains deposits of uranium ore, which are likely to be found in: the Bima Sandstones of Wade, Shinga, Bima hill, Wuyo, Teli, Bryel, Dali, Barkan, Gasi, Kunkun, Boragara, Deba, and Gberundi localities; the anatectic migmatite at Kubuku, Whada

  16. From Funding Liquidity to Market Liquidity

    DEFF Research Database (Denmark)

    Dick-Nielsen, Jens; Lund, Jesper; Gyntelberg, Jacob

    This paper shows empirically that funding liquidity drives market liquidity. As it becomes harder to secure term funding in the money markets, liquidity deteriorates in the Danish bond market. We show that the first principal component of bond market liquidity is driven by the market makers' abil...... for other European government bonds using MTS data. The findings suggest that regulatory bond based liquidity buffers for banks will have limited effectiveness.......This paper shows empirically that funding liquidity drives market liquidity. As it becomes harder to secure term funding in the money markets, liquidity deteriorates in the Danish bond market. We show that the first principal component of bond market liquidity is driven by the market makers...

  17. Liquidation of the company

    OpenAIRE

    Procházka, Michal

    2011-01-01

    This work deals with the liquidation of the company focusing on commercial companies. It describes whole process of liquidation from decision to liquidate to delete the company from the Commercial Register. The work also focuses on legal, accounting and tax site of liquidation. Accounting practices in the liquidation process are illustrated on the example of a fictive company.

  18. Structural and photocarrier radiometric characterization of Cu{sub x}(CdTe){sub y}O{sub z} thin films growth by reactive sputtering

    Energy Technology Data Exchange (ETDEWEB)

    Velazquez-Hernandez, R., E-mail: ruvel2@yahoo.com.m [Division de Investigacion y Posgrado, Facultad de Ingenieria, Universidad Autonoma de Queretaro, Cerro de las Campanas S/N, Queretaro, Qro., Mexico, C.P. 76010 (Mexico); Rojas-Rodriguez, I. [Universidad Tecnologica de Queretaro, Av. Pie de la Cuesta S/N, Sn. Pedrito Penuelas, Queretaro, Qro. Mexico (Mexico); Carmona-Rodriguez, J.; Jimenez-Sandoval, S. [Centro de Investigacion y de Estudios Avanzados del IPN, Unidad Queretaro, Apartado Postal 1-798, Queretaro, Qro., Mexico C.P.76001 (Mexico); Rodriguez-Garcia, M.E. [Departamento de Nanotecnologia, Centro de Fisica Aplicada y Tecnologia Avanzada, Universidad Nacional Autonoma de Mexico, Campus Juriqulla, Apartado Postal 1-1010, Queretaro, Qro. Mexico (Mexico)

    2011-01-31

    This research presents a structural and photocarrier radiometric (PCR) characterization of Cu{sub x}(CdTe){sub y}O{sub z} thin films grown using reactive radiofrequency co-sputtering. Electronic distribution induced by variations in dopant concentration as a function of the position was studied using photocarrier radiometric images. Optical and structural characterization of these thin films was carried out by using micro Raman spectroscopy and X-ray diffraction. Due to its nondestructive and noncontact characteristics, the PCR is an excellent technique that permits one to obtain details of lateral electronic distribution across the sample. It was found that Cu target power influences the electronic distribution and produces different phases such as Cu{sub 2}Te and CdO.

  19. A Method to Estimate Uncertainty in Radiometric Measurement Using the Guide to the Expression of Uncertainty in Measurement (GUM) Method; NREL (National Renewable Energy Laboratory)

    Energy Technology Data Exchange (ETDEWEB)

    Habte, A.; Sengupta, M.; Reda, I.

    2015-03-01

    Radiometric data with known and traceable uncertainty is essential for climate change studies to better understand cloud radiation interactions and the earth radiation budget. Further, adopting a known and traceable method of estimating uncertainty with respect to SI ensures that the uncertainty quoted for radiometric measurements can be compared based on documented methods of derivation.Therefore, statements about the overall measurement uncertainty can only be made on an individual basis, taking all relevant factors into account. This poster provides guidelines and recommended procedures for estimating the uncertainty in calibrations and measurements from radiometers. The approach follows the Guide to the Expression of Uncertainty in Measurement (GUM). derivation.Therefore, statements about the overall measurement uncertainty can only be made on an individual basis, taking all relevant factors into account. This poster provides guidelines and recommended procedures for estimating the uncertainty in calibrations and measurements from radiometers. The approach follows the Guide to the Expression of Uncertainty in Measurement (GUM).

  20. Non-invasive hyperthermia apparatus including coaxial applicator having a non-invasive radiometric receiving antenna incorporated therein and method of use thereof

    Science.gov (United States)

    Ross, M.P.

    1996-08-27

    A coaxial hyperthermia applicator is disclosed for applying non-invasively electromagnetic energy to a body against which it is placed. The coaxial applicator antenna has formed integrally within it a non-invasive radiometric antenna for receiving thermoelectromagnetic emissions. The coaxial-configured applicator produces a bell-shaped radiation pattern symmetric about the axis of symmetry of the coaxial applicator. Integrating the radiometric antenna within the coaxial applicator produces a single device that performs dual functions. The first function is to transmit non-invasively energy for heating a subcutaneous tumor. The second function is to receive non-invasively thermal electromagnetic radiation from the tumor by which temperature is sensed and fed back to control the output of the coaxial applicator. 11 figs.

  1. Usefulness of systematic in situ gamma-ray surveys in the radiometric characterization of natural systems with poorly contrasting geological features (examples from NE of Portugal)

    Energy Technology Data Exchange (ETDEWEB)

    Duarte, Pedro [Instituto Tecnologico e Nuclear, Unidade de Proteccao e Seguranca Radiologica, Estrada Nacional no10, Apartado 21, 2686-953 Sacavem (Portugal); Departamento de Geologia e CeGUL, Faculdade de Ciencias da Universidade de Lisboa, Campo Grande, Edificio C6, 1749-016 Lisboa (Portugal); Mateus, Antonio [Departamento de Geologia e CeGUL, Faculdade de Ciencias da Universidade de Lisboa, Campo Grande, Edificio C6, 1749-016 Lisboa (Portugal); Paiva, Isabel, E-mail: ipaiva@itn.p [Instituto Tecnologico e Nuclear, Unidade de Proteccao e Seguranca Radiologica, Estrada Nacional no10, Apartado 21, 2686-953 Sacavem (Portugal); Trindade, Romao [Instituto Tecnologico e Nuclear, Unidade de Proteccao e Seguranca Radiologica, Estrada Nacional no10, Apartado 21, 2686-953 Sacavem (Portugal); Santos, Pedro [Instituto Tecnologico e Nuclear, Unidade de Proteccao e Seguranca Radiologica, Estrada Nacional no10, Apartado 21, 2686-953 Sacavem (Portugal); Departamento de Geologia e CeGUL, Faculdade de Ciencias da Universidade de Lisboa, Campo Grande, Edificio C6, 1749-016 Lisboa (Portugal)

    2011-02-15

    This paper focuses on the starting point of various studies that are being carried out in two possible locations being considered to host a hypothetical site for a repository for low and intermediate level radioactive waste (LILW) produced in Portugal in compliance with international requirements on the long-term safety of this kind of repository. Previous studies concerning the geology of the much larger geographical areas where these locations are included were fundamental in the choice of these locations and for the design of the survey strategy. One of the fundamental assessment studies during the site-selection is the overall radiological characterization of the locations and its relation to the geology. This paper pretends to show the adequability of using a fast and reasonably inexpensive survey technique such as in situ gamma-ray portable detectors, to access the radiometric response of the systems in study by providing the radiometric mapping of the areas. The existence of adequate radiometric maps represents a critical pre-requisite to constrain both the number and spatial distribution of samples to be collected for further analysis, sustaining as well the subsequent extrapolation of results needed to fully characterise the surveyed system. Both areas were surveyed using portable gamma-ray spectrometers with NaI(Tl) detectors. In situ gamma-ray measurements have clearly shown not only the poorly contrasting geological features, but also their differences representing: (i) a deformed/metamorphosed ophiolite complex and (ii) a monotonous meta-sedimentary sequence. The radiometric maps obtained have show heterogeneities that reflect mostly changes in rock-forming mineral assemblages, even in the presence of small variations of gamma radiation. These maps support objective criteria about the number/distribution of samples to be collected for subsequent comprehensive studies and reinforce the valuable contribution of in situ gamma spectrometry to assess, in

  2. An Assessment of Polynomial Regression Techniques for the Relative Radiometric Normalization (RRN of High-Resolution Multi-Temporal Airborne Thermal Infrared (TIR Imagery

    Directory of Open Access Journals (Sweden)

    Mir Mustafizur Rahman

    2014-11-01

    Full Text Available Thermal Infrared (TIR remote sensing images of urban environments are increasingly available from airborne and satellite platforms. However, limited access to high-spatial resolution (H-res: ~1 m TIR satellite images requires the use of TIR airborne sensors for mapping large complex urban surfaces, especially at micro-scales. A critical limitation of such H-res mapping is the need to acquire a large scene composed of multiple flight lines and mosaic them together. This results in the same scene components (e.g., roads, buildings, green space and water exhibiting different temperatures in different flight lines. To mitigate these effects, linear relative radiometric normalization (RRN techniques are often applied. However, the Earth’s surface is composed of features whose thermal behaviour is characterized by complexity and non-linearity. Therefore, we hypothesize that non-linear RRN techniques should demonstrate increased radiometric agreement over similar linear techniques. To test this hypothesis, this paper evaluates four (linear and non-linear RRN techniques, including: (i histogram matching (HM; (ii pseudo-invariant feature-based polynomial regression (PIF_Poly; (iii no-change stratified random sample-based linear regression (NCSRS_Lin; and (iv no-change stratified random sample-based polynomial regression (NCSRS_Poly; two of which (ii and iv are newly proposed non-linear techniques. When applied over two adjacent flight lines (~70 km2 of TABI-1800 airborne data, visual and statistical results show that both new non-linear techniques improved radiometric agreement over the previously evaluated linear techniques, with the new fully-automated method, NCSRS-based polynomial regression, providing the highest improvement in radiometric agreement between the master and the slave images, at ~56%. This is ~5% higher than the best previously evaluated linear technique (NCSRS-based linear regression.

  3. High pH solubilization and chromatography-based renaturation and purification of recombinant human granulocyte colony-stimulating factor from inclusion bodies.

    Science.gov (United States)

    Li, Ming; Fan, Hua; Liu, Jiahua; Wang, Minhong; Wang, Lili; Wang, Chaozhan

    2012-03-01

    Recombinant human granulocyte colony-stimulating factor (rhG-CSF) is a very efficient therapeutic protein drug which has been widely used in human clinics to treat cancer patients suffering from chemotherapy-induced neutropenia. In this study, rhG-CSF was solubilized from inclusion bodies by using a high-pH solution containing low concentration of urea. It was found that solubilization of the rhG-CSF inclusion bodies greatly depended on the buffer pH employed; alkalic pH significantly favored the solubilization. In addition, when small amount of urea was added to the solution at high pH, the solubilization was further enhanced. After solubilization, the rhG-CSF was renatured with simultaneous purification by using weak anion exchange, strong anion exchange, and hydrophobic interaction chromatography, separately. The results indicated that the rhG-CSF solubilized by the high-pH solution containing low concentration of urea had much higher mass recovery than the one solubilized by 8 M urea when using anyone of the three refolding methods employed in this work. In the case of weak anion exchange chromatography, the high pH solubilized rhG-CSF could get a mass recovery of 73%. The strategy of combining solubilization of inclusion bodies at high pH with refolding of protein using liquid chromatography may become a routine method for protein production from inclusion bodies.

  4. Rapid Detection of Mycobacterium paratuberculosis in Clinical Samples from Ruminants and in Spiked Environmental Samples by Modified BACTEC 12B Radiometric Culture and Direct Confirmation by IS900 PCR

    OpenAIRE

    Whittington, R. J.; Marsh, I.; Turner, M J; McAllister, S; Choy, E.; Eamens, G J; Marshall, D.J.; Ottaway, S.

    1998-01-01

    The suitability of a radiometric culture medium consisting of BACTEC 12B with PANTA PLUS, mycobactin J, and egg yolk was evaluated for detection of Mycobacterium paratuberculosis in feces, mesenteric lymph nodes, and intestinal walls from cattle, sheep, and goats. In addition, a simple method that would enable the rapid identification of Mycobacterium paratuberculosis by IS900 PCR in the primary cultures was sought so that subculture to secondary egg-free radiometric medium could be avoided. ...

  5. Simultaneous Retrieval of Aerosol and Surface Optical Properties from Combined Airborne- and Ground-Based Direct and Diffuse Radiometric Measurements

    Science.gov (United States)

    Gatebe, C. K.; Dubovik, O.; King, M. D.; Sinyuk, A.

    2010-01-01

    This paper presents a new method for simultaneously retrieving aerosol and surface reflectance properties from combined airborne and ground-based direct and diffuse radiometric measurements. The method is based on the standard Aerosol Robotic Network (AERONET) method for retrieving aerosol size distribution, complex index of refraction, and single scattering albedo, but modified to retrieve aerosol properties in two layers, below and above the aircraft, and parameters on surface optical properties from combined datasets (Cloud Absorption Radiometer (CAR) and AERONET data). A key advantage of this method is the inversion of all available spectral and angular data at the same time, while accounting for the influence of noise in the inversion procedure using statistical optimization. The wide spectral (0.34-2.30 m) and angular range (180 ) of the CAR instrument, combined with observations from an AERONET sunphotometer, provide sufficient measurement constraints for characterizing aerosol and surface properties with minimal assumptions. The robustness of the method was tested on observations made during four different field campaigns: (a) the Southern African Regional Science Initiative 2000 over Mongu, Zambia, (b) the Intercontinental Transport Experiment-Phase B over Mexico City, Mexico (c) Cloud and Land Surface Interaction Campaign over the Atmospheric Radiation Measurement (ARM) Central Facility, Oklahoma, USA, and (d) the Arctic Research of the Composition of the Troposphere from Aircraft and Satellites (ARCTAS) over Elson Lagoon in Barrow, Alaska, USA. The four areas are dominated by different surface characteristics and aerosol types, and therefore provide good test cases for the new inversion method.

  6. San Bernardino Cave (Italy and the appearance of Levallois technology in Europe: results of a radiometric and technological reassessment.

    Directory of Open Access Journals (Sweden)

    Andrea Picin

    Full Text Available The introduction of Levallois technology in Europe marked the transition from the Lower to the early Middle Paleolithic. This new method of flake production was accompanied by significant behavioral changes in hominin populations. The emergence of this technological advance is considered homogeneous in the European archaeological record at the Marine isotopic stage (MIS 9/MIS 8 boundary. In this paper we report a series of combined electron spin resonance/U-series dates on mammal bones and teeth recovered from the lower units of San Bernardino Cave (Italy and the technological analyses of the lithic assemblages. The San Bernardino Cave has yielded the earliest evidence of Levallois production on the Italian Peninsula recovered to date. In addition to our results and the review of the archaeological record, we describe the chronological and geographical differences between European territories and diversities in terms of technological developments. The belated emergence of Levallois technology in Italy compared to western Europe corresponds to the late Italian Neanderthal speciation event. The new radiometric dates and the technological analyses of San Bernardino Cave raise the issue of the different roles of glacial refugia in the peopling and the spread of innovative flaking strategies in Europe during the late Middle Pleistocene.

  7. Radiometric cytolysis inhibition assay, a new rapid test for neutralizing antibodies to intact and trypsin-cleaved poliovirus

    Energy Technology Data Exchange (ETDEWEB)

    Hovi, T.; Roivainen, M.

    1989-04-01

    We have developed a new rapid test, the radiometric cytolysis inhibition assay (RACINA), for the determination of neutralizing poliovirus antibodies. HeLa cells prelabeled with /sup 51/Cr, (/sup 3/H)leucine, or, preferentially, with (/sup 3/H)uridine are used as sensitive quantitative indicators of residual infectious virus. Both suspensions and monolayer cultures of the indicator cells can be used. Neutralization of a fraction of a high-titer virus preparation can be scored after the first replication cycle at 8 to 10 h. By lowering the incubation temperature to 30/degree/C, the completion of the cytolysis due to the first replication cycle of poliovirus was delayed beyond 21 h. This makes it possible to use the RACINA, unlike the standard microneutralization assay, for measuring antibodies to trypsin-cleaved polioviruses. The RACINA was found to be as sensitive as and more reproducible than the standard microneutralization assay in the measurement of neutralizing poliovirus antibodies. The RACINA is a rapid and reliable test for neutralizing antibodies and in principle it may be applicable for quantitation of neutralizing antibodies to other cytolytic agents as well.

  8. Airborne Geophysical Surveys in the North-Central Region of Goias (Brazil): Implications for Radiometric Characterization of Subtropical Soils

    CERN Document Server

    Guimarães, S N P; Justo, J S

    2011-01-01

    In this work we present progress obtained in analysis airborne geophysical survey data for the north-central region of the state of Goias (Brazil). The results obtained indicate that most of the subtropical soil types are characterized by Uranium contents of greater than one parts per million (ppm). Only ultisol and oxisol soils are found to have Uranium contents lower than one ppm. Thorium and Potassium abundances also display trends similar to those of Uranium. The K/U ratios fall in the expected range of values for common soils while the Th/U ratios are higher than normal. This latter observation may indicate a characteristic feature of subtropical soils. Alternatively it may be considered as indicative of disequilibrium conditions in radioactive series and consequent underestimation of Uranium in soil layers of the study area. In this context we point out the possibility of using results of radiometric surveys as a convenient complementary tool in identifying geochemical zoning of soils in subtropical env...

  9. Radiometric age determination of tonsteins and stratigraphic constraints for the Lower Permian coal succession in southern Parana Basin, Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Guerra-Sommer, Margot; Cazzulo-Klepzig, Miriam; Hartmann, Leo Afraneo; Formoso, Milton Luis Laquintinie [Instituto de Geociencias, Universidade Federal do Rio Grande do Sul, Avenida Bento Goncalves, 9500, 91501-970 Porto Alegre, Rio Grande do Sul (Brazil); Santos, Joao Orestes Schneider [Centre for Global Targeting, University of Western Australia, Crawley, Perth 6009, WA (Australia); Ketzer, Joao Marcelo [Instituto de Meio Ambiente, Pontificia Universidade Catolica, Avenida Ipiranga, Porto Alegre, Rio Grande do Sul (Brazil)

    2008-03-03

    Ion microprobe (SHRIMP II) dating of zircons from tonsteins interbedded with coal seams from the Candiota and Faxinal coalfields (Early Permian, Rio Bonito Formation, Parana Basin, Brazil) is presented. The mean ages obtained (290.6 {+-} 1.5 Ma) are more precise than previously published intervals. Calibrations of chronostratigraphic data with radiometric ages show that the main coal succession from the southern Basin is constrained to the Middle Sakmarian. The {+-} 2 Ma time interval of deposition supports the hypothesis that the coal-generating process was quite rapid in terms of geological time. In a general context, Faxinal and Candiota coals are assigned, into the Protohaploxypinus goraiensis Subzone, besides some paleocological differences evidenced by palynological studies. This bio-interval does not correspond to a consistent palynostratigraphic tool and more accurate biostratigraphic zonation for the Carboniferous-Permian interval must be delineated. The new results have far-reaching significance for correlations of the Basin with sequences of the Argentinian Paganzo Basin (302 {+-} 6 Ma and 288 {+-} 7 Ma) and also with the Karoo Basin, with the lowermost Ecca Group (288 {+-} 3 Ma and 289.6 {+-} 3.8 Ma). This new evidence supports the presence of an active and widespread Lower Permian explosive volcanic event in western Gondwana, which is interpreted as the same volcanism which produced the Choiyoi Group in western Argentina. According to this correlation the ash-fall source is located about 1400 km to the southwest of their area of deposition. (author)

  10. Some observations from radiometric ‘8 bit’ data of sediment thin sections based on alternative petrographic image analysis method

    Indian Academy of Sciences (India)

    Sudip Dey; Suvendu Ghosh; Chandrani Debbarma; Prasamita Sarkar; Mhu Aris Marfai; Sabyasachi Maiti

    2009-04-01

    This paper deals with the experiment of sediment microstructure analysis especially microfabric mapping by digital imaging.For that purpose the greyscale images (Red band from RGB combination)of the thin sections have been prepared from the selected 12 samples.The basis of this mapping is the reflectance capacity of different sediments which is influenced by the physical parameters like grain size and colour.The reflectances of different sediments are represented in digital format by different DN values from 0 –255 within the radiometric ranges of ‘8 bit ’data. Density slicing has been chosen as the method of microstructure mapping in this research.This study shows that lower DN values normally present dark coloured coarser sand and clay while higher DN values present light coloured finer sediment samples.In the selected samples for this study the maximum DN value has been found from micaceous materials.Another remarkable thing observed from the microfabric mapping is that the presence of coarser sediments forms complex microfabric pattern than the finer sediments in the study area.Though this method have some demerits,still its simple technique can be very useful for accurate microstructure analysis.

  11. Radiometric discrimination of pre-Variscan amphibolites in the Ediacaran Serie Negra (Ossa-Morena Zone, SW Iberia)

    Science.gov (United States)

    Sánchez-Lorda, M. E.; Ábalos, B.; García de Madinabeitia, S.; Eguíluz, L.; Gil Ibarguchi, J. I.; Paquette, J.-L.

    2016-06-01

    New results on the geochronology of metabasites hosted by the Neoproterozoic (late Ediacaran) Serie Negra of the Ossa-Morena Zone (Iberian Massif) are presented. These rocks record a protracted subduction at least since the latest Cryogenian, followed in a continuum by early Cambrian rifting. The Serie Negra country rocks are continental-crust forearc segments of the thinned continental margin of Gondwana. The metabasite suite exhibits E- and N-MORB, as well as volcanic arc signatures, and discloses the existence of a diverse Late Ediacaran-Early Cambrian magmatism across the Ossa-Morena Zone. Protoliths of the E-MORB metabasites are clearly Ediacaran. They exhibit geochemical characteristics typical of younger island arcs, notably of their forearc zones affected by extension soon after the initiation of subduction. Radiometric dating of N-MORB metabasites shows that these rocks are significatively younger than their country rocks, whose age has been stratigraphically and paleontologically constrained as Ediacaran. They record early Cambrian rifting developed in a continuum after a protracted subduction. Metabasite petrological zonation permits to reconstruct a single Ediacaran subduction zone located to the S of the current OMZ and dipping towards the N (in present day geographical coordinates).

  12. Radiometric assay for cytochrome P-450-catalyzed progesterone 16 alpha-hydroxylation and determination of an apparent isotope effect

    Energy Technology Data Exchange (ETDEWEB)

    Osawa, Y.; Coon, M.J.

    1987-08-01

    In the course of studies on the oxygenation of steroids by purified P-450 cytochromes, particularly rabbit liver microsomal cytochrome P-450 form 3b, a rapid and reliable radiometric assay has been devised for progesterone 16 alpha-hydroxylation. In view of the lack of a commercially available, suitably tritiated substrate, (1,2,6,7,16,17-3H)progesterone was treated with alkali to remove the label from potential hydroxylation sites other than the 16 alpha position. The resulting (1,7,16-3H)progesterone was added to a reconstituted enzyme system containing cytochrome P-450 form 3b, NADPH-cytochrome P-450 reductase, and NADPH, and the rate of 16 alpha-hydroxylation was measured by the formation of /sup 3/H/sub 2/O. This reaction was shown to be linear with respect to time and to the cytochrome P-450 concentration. An apparent tritium isotope effect of 2.1 was observed by comparison of the rates of formation of tritium oxide and 16 alpha-hydroxyprogesterone, and the magnitude of the isotope effect was confirmed by an isotope competition assay in which a mixture of (1,7,16-/sup 3/H)progesterone and (4-14C)progesterone was employed.

  13. Clinical comparison of the Isolator 1. 5 microbial tube and the BACTEC radiometric system for detection of bacteremia in children

    Energy Technology Data Exchange (ETDEWEB)

    Carey, R.B.

    1984-05-01

    The Isolator 1.5 microbial tube was compared with the BACTEC radiometric detection system for the detection of bacteremia in children. The Isolator 1.5 is a blood culture system designed for small volumes of blood (0.5 to 1.5 ml). The method involves lysis of the cells of the patient and the direct plating of the entire blood lysate on agar media appropriate for the growth of fastidious microorganisms. Of 1,500 paired samples inoculated into the two systems, 68 were positive for 73 clinically significant organisms. The Isolator 1.5 recovered 81% of the positive cultures compared with 84% recovered by the BACTEC system. The contamination rates were 8.7 and 3.1% for the Isolator 1.5 and the BACTEC system, respectively. In cultures positive by both systems, the mean time to detection was 4.1 h faster with the Isolator 1.5. The mean time to obtain isolated colonies was 26.6 h faster with the Isolator 1.5. These data indicate the potential value of the Isolator 1.5 microbial tube as a simple, rapid, and sensitive method for the detection of bacteremia in children.

  14. Comparative evaluation of Oxoid Signal and BACTEC radiometric blood culture systems for the detection of bacteremia and fungemia

    Energy Technology Data Exchange (ETDEWEB)

    Weinstein, M.P.; Mirrett, S.; Reller, L.B.

    1988-05-01

    The Oxoid Signal blood culture system is a newly described, innovative method for visually detecting growth of microorganisms. We did 5,999 paired comparisons of equal volumes (10 ml) of blood in the Oxoid Signal and BACTEC radiometric blood culture systems at two university hospitals that use identical methods of obtaining and processing specimens. Overall, more microorganisms were detected in the BACTEC system (P less than 0.001), in particular, streptococci (P less than 0.01), fungi (P less than 0.001), and nonfermentative gram-negative rods, especially Acinetobacter species (P less than 0.001). Trends favoring the BACTEC system for detection of Pseudomonas aeruginosa, Haemophilus species, and Neisseria species were noted. There were no differences in the yield of staphylococci, members of the family Enterobacteriaceae, and anaerobic bacteria. When both systems detected sepsis, the BACTEC did so earlier (P less than 0.001). This advantage was most notable at 24 h (70% of BACTEC positives detected versus 48% of Oxoid positives). The proportion of positives detected after 48 h, however, was similar (BACTEC, 84%; Oxoid, 78%). Revisions in the Oxoid Signal system itself or in the processing of Oxoid bottles appear to be necessary to improve its performance in detecting certain microorganism groups, especially fungi.

  15. Study on a mean radiant temperature measure tool based on an almost spherical array of radiometric sensors.

    Science.gov (United States)

    Fontana, L

    2012-11-01

    Mean radiant temperature has significant influence on indoor thermal comfort conditions. It has gained greater importance with the wider application of heating and cooling systems based on the use of large surfaces with a temperature slightly higher or lower than the indoor temperature (hot/cold floors or ceilings), because these systems operate through the radiant temperature control. The most used tool to measure radiant temperature, the globe thermometer, still has large margins of error, most of all due to the uncertainty in the evaluation of the convection heat exchanges between the globe surface and the indoor air. The feasibility of a device to measure mean radiant temperature in indoor condition, alternative to the globe-thermometer (obtained placing radiometric sensors (thermopiles) on the sides of different geometric regular solids), is proposed. The behavior has been investigated for different regular solids, such as the residual error and its dependence on walls average temperature, non-uniformity magnitude, orientation and position of the solid in the enclosure, room shape, non-uniformity temperature distribution. Icosahedron shape shows an excellent behavior, with errors lower than 0.1 K in all the examined conditions.

  16. Compilation of radiometric age and trace-element geochemical data, Yucca Mountain and surrounding areas of southwestern Nevada

    Energy Technology Data Exchange (ETDEWEB)

    Weiss, S.I.; Noble, D.C.; Larson, L.T.

    1994-12-31

    This document is a compilation of available radiometric age and trace-element geochemical data for volcanic rocks and episodes of hydrothermal activity in Yucca Mountain and the surrounding region of southwestern Nevada. Only the age determinations considered to be geologically reasonable (consistent with stratigraphic relations) are listed below. A number of the potassium-argon (K-Ar) ages of volcanic rocks given by Kistler, Marvin et al., Noble et al., Weiss et al., and Noble et al. are not included as these ages have been shown to be incorrect or disturbed by hydrothermal alteration based on subsequent stratigraphic and/or petrographic data and the recognition of errors in K-Ar age determinations related to incomplete extraction of argon. In cases where absolute ages are tightly constrained by high precision {sup 40}Ar/{sup 39}Ar ages and unequivocal stratigraphic relations, we have omitted the less precise K-Ar age data. Similarly, the more precise single-crystal laser-fusion {sup 40}Ar/{sup 39}Ar age determinations of certain units are reported and less precise ages by multi-grain bulk-fusion {sup 40}Ar/{sup 39}Ar methods are not included. This compilation does not include age data for basaltic rocks of Pliocene and Quaternary age in the Yucca Mountain region.

  17. [Estimation models of vegetation fractional coverage (VFC) based on remote sensing image at different radiometric correction levels].

    Science.gov (United States)

    Gu, Zhu-Jun; Zeng, Zhi-Yuan; Shi, Xue-Zheng; Yu, Dong-Sheng; Zheng, Wei; Zhang, Zhen-Long; Hu, Zi-Fu

    2008-06-01

    The images of post atmospheric correction reflectance (PAC), top of atmosphere reflectance (TOA), and digital number (DN) of a SPOT5 HRG remote sensing image of Nanjing, China were used to derive four vegetation indices (VIs), i. e., normalized difference vegetation index (NDVI), transformed vegetation index (TVI), soil-adjusted vegetation index (SAVI), and modified soil-adjusted vegetation index (MSAVI), and 36 VI-VFC relationship models were established based on these VIs and the VFC data obtained from ground measurement. The results showed that among the models established, the cubic polynomial models based on NDVI and TVI from PAC were the best, followed by those based on SAVI and MSAVI from DN, with the accuracy being slightly higher than that of the former two models when VFC > 0.8. The accuracy of these four models was higher in middle-densely vegetated areas (VFC = 0.4-0.8) than in sparsely vegetated areas (VFC = 0-0.4). All the established models could be used in other places via the introduction of calibration models. In VI-VFC modeling, using VIs derived from different radiometric correction levels of remote sensing image could help mining valuable information from remote sensing image, and thus, improving the accuracy of VFC estimation.

  18. Spectral radiant power measurements of VUV and soft x-ray sources using the electron storage ring BESSY as a radiometric standard source.

    Science.gov (United States)

    Fischer, J; Kühne, M; Wende, B

    1984-12-01

    A method is described for measuring the spectral radiant power of VUV and soft x-ray sources using the electron storage ring BESSY as a radiometric standard source of calculable spectral radiant power and degree of polarization. An ellipsoidal grazing incidence mirror stigmatically images the stored electrons or the source under investigation in equal optical conditions into a toroidal grating monochromator. The monochromator can be rotated around its optical axis in UHV conditions to account for different degrees of polarization of the two sources. The accuracy presently available with this method is demonstrated by a measurement of the spectral concentration of radiant intensity of a laser-produced tungsten plasma in the wavelength range between 7 and 100 nm with an overall uncertainty of 10%. A detailed analysis of the contributions to this uncertainty shows that the major part of it is caused by the presently uncertain knowledge of the polarizing properties of the radiometric instrumentation and by the uncertainty of the correction procedure which accounts for the influence of higher diffraction orders of the monochromator grating. The results of the radiation measurements of the laser-produced tungsten plasma let us expect that this source type has the potential to serve as a radiometric transfer standard in the VUV and soft x-ray range below 100 nm.

  19. The effect of image radiometric correction on the accuracy of vegetation canopy density estimate using several Landsat-8 OLI’s vegetation indices: A case study of Wonosari area, Indonesia

    Science.gov (United States)

    Dewa, R. P.; Danoedoro, P.

    2017-01-01

    Recent studies on the use of spectral indices have involved radiometric correction as a prerequisite. However, study on the effect of radiometric correction level on the accuracy of biophysical parameters’ estimate is still rare in Indonesia. This study tried to investigate the influence of various radiometric correction levels and the number of vegetation strata on the accuracy of vegetation density estimates using NDVI, MSAVI2 and GEMI of Landsat 8 OLI. In this study, the dataset covering vegetated area in Wonosari, Gunung Kidul Regency, Indonesia was processed radiometrically using eight different methods, i.e. spectral radiance, at sensor reflectance, sun elevation correction, histogram adjustments using original DN, spectal radiance, at sensor reflectance, and sun position correction respectively, as well as dark object subtraction (DOS). Every image with specific correction level was then transformed using the aforementioned indices, in order correlate with the field-measured canopy density. The analysis were carried out by considering the number of canopy layers. This found that different radiometric correction methods resulted canopy density estimates with different accuracies. The number of canopy strata also played an important role. Every vegetation index transformation performed its best accuracy by using different radiometric correction method and different number of canopy layers.

  20. CASH AND LIQUIDITY/LIQUIDITY AND LIQUIDITY RATIO

    Directory of Open Access Journals (Sweden)

    BEATRIX LIGHEZAN BREUER

    2012-12-01

    Full Text Available The present paper aims to present the correlation as well as the differences between liquidity/cash and liquidity ratio in terms of economic entities. Researches on this topic are based on the opinions of some specialists in accounting and in the economic-financial analysis, as well as on the national legal stipulations and the ones set out in the International Accounting Standards, the Financial report, respectively. The object of this paper is represented by the correlation between liquidity/cash and liquidity ratios representing the liquidity as current assets, assets implied in the determination of liquidity ratios. The end of the paper consists of the conclusions drawn from the issues presented in the paper but also our views on this research topic.

  1. Dust Provenance and Radiometric U-Series Ages as Evidence for an Eemian Ice Sheet in Greenland

    Science.gov (United States)

    Aciego, S.; Bourdon, B.; Schwander, J.; Stocker, T. F.

    2009-12-01

    The mineralogy and geochemistry of air-transported mineral particles, dust, reflect the prior history of the source material as well as influence the chemistry of the settling locations (rivers, ice sheets and ultimately the oceans). When applied to ice sheets, the atmospheric circulation patterns gleaned from the chemical characteristics of the dust may provide some additional constraints on size and shape of paleo-ice sheets. Furthermore, the ice bound dust grains can be used to determine the age of the ice by using uranium series recoil as a radiometric dating method, provided there is sufficient information about the size and shape of the dust grains and the [U] concentration and isotopic (234U/238U) composition of the ice and dust. The Dye3 ice core is the southern-most deep ice core in Greenland, so should provide a minimum estimate of ice sheet size in the past: the existence of ice is evidence for an ice sheet at any given time. A series of samples from 200 m to 2030 m in depth were analyzed by MC-ICPMS and TIMS for U concentrations and 234U/238U as well as 176Hf/177Hf, 87Sr/86Sr, and 143Nd/144Nd. The radiogenic isotopic compositions of the insoluble dust found in the upper 1800 m falls within the range of previously measured Greenland dust samples: 87Sr/86Sr = 0.7108 - 0.7174, ɛNd = -9.7 - -13.6, and ɛHf = -2 - -5. However, the data trends toward significantly more unradiogenic Nd and Hf and radiogenic Sr values in the lower 100 m: 87Sr/86Sr = 0.7167 - 0.7200, ɛNd = -15.62 - -17.36, and ɛHf = -21 - -25; the deepest sample containing basal sediments having the most extreme values: 87Sr/86Sr = 0.7349 - 0.7785 ɛNd = -37.48 - -41.61, and ɛHf = -24.8 - -39.54. The calculated 234U/238U radiometric age for the deepest ice ranges from 90 to 110 ± 50 ka, in the same range as two possible age models for the Dye3 location, indicating the deepest ice is in the range of 40-60 ka or 85-120 ka. However, based on the radiogenic isotopes, while the dust in the

  2. Simultaneous retrieval of aerosol and surface optical properties from combined airborne- and ground-based direct and diffuse radiometric measurements

    Directory of Open Access Journals (Sweden)

    C. K. Gatebe

    2009-12-01

    Full Text Available This paper presents a new method for simultaneously retrieving aerosol and surface reflectance properties from combined airborne and ground-based direct and diffuse radiometric measurements. The method is based on the standard Aerosol Robotic Network (AERONET method for retrieving aerosol size distribution, complex index of refraction, and single scattering albedo, but modified to retrieve aerosol properties in two layers, below and above the aircraft, and parameters on surface optical properties from combined datasets (Cloud Absorption Radiometer, CAR, and AERONET data. A key advantage of this method is the inversion of all available spectral and angular data at the same time, while accounting for the influence of noise in the inversion procedure using statistical optimization. The wide spectral (0.34–2.30 μm and angular range (180° of the CAR instrument, combined with observations from an AERONET sunphotometer, provide sufficient measurement constraints for characterizing aerosol and surface properties with minimal assumptions. The robustness of the method was tested on observations made during four different field campaigns: (a the Southern African Regional Science Initiative 2000 over Mongu, Zambia, (b the Intercontinental Transport Experiment-Phase B over Mexico City, Mexico (c Cloud and Land Surface Interaction Campaign over the Atmospheric Radiation Measurement (ARM Central Facility, Oklahoma, USA, and (d the Arctic Research of the Composition of the Troposphere from Aircraft and Satellites (ARCTAS over Elson Lagoon in Barrow, Alaska, USA. The four areas are dominated by different surface characteristics and aerosol types, and therefore provide good test cases for the new inversion method.

  3. AERONET-OC: Strengths and Weaknesses of a Network for the Validation of Satellite Coastal Radiometric Products

    Science.gov (United States)

    Zibordi, Giuseppe; Holben, Brent; Slutsker, Ilya; Giles, David; D'Alimonte, Davide; Melin, Frederic; Berthon, Jean-Francois; Vandemark, Doug; Feng, Hui; Schuster, Gregory; Fabbri, Bryan E.; Kaitala, Seppo; Seppala, Jukka

    2008-01-01

    The Ocean Color component of the Aerosol Robotic Network (AERONET-OC) has been implemented to support long-term satellite ocean color investigations through cross-site consistent and accurate measurements collected by autonomous radiometer systems deployed on offshore fixed platforms. The ultimate purpose of AERONET-OC is the production of standardized measurements performed at different sites with identical measuring systems and protocols, calibrated using a single reference source and method, and processed with the same code. The AERONET-OC primary data product is the normalized water leaving radiance determined at center-wavelengths of interest for satellite ocean color applications, with an uncertainty lower than 5% in the blue-green spectral regions and higher than 8% in the red. Measurements collected at 6 sites counting the northern Adriatic Sea, the Baltic Proper, the Gulf of Finland, the Persian Gulf, and, the northern and southern margins of the Middle Atlantic Bay, have shown the capability of producing quality assured data over a wide range of bio-optical conditions including Case-2 yellow substance- and sedimentdominated waters. This work briefly introduces network elements like: deployment sites, measurement method, instrument calibration, processing scheme, quality-assurance, uncertainties, data archive and products accessibility. Emphases is given to those elements which underline the network strengths (i.e., mostly standardization of any network element) and its weaknesses (i.e., the use of consolidated, but old-fashioned technology). The work also addresses the application of AERONET-OC data to the validation of primary satellite radiometric products over a variety of complex coastal waters and finally provides elements for the identification of new deployment sites most suitable to support satellite ocean color missions.

  4. Loss of surface horizon of an irrigated soil detected by radiometric images of normalized difference vegetation index.

    Science.gov (United States)

    Fabian Sallesses, Leonardo; Aparicio, Virginia Carolina; Costa, Jose Luis

    2017-04-01

    The use of the soil in the Humid Pampa of Argentina has changed since the mid-1990s from agricultural-livestock production (that included pastures with direct grazing) to a purely agricultural production. Also, in recent years the area under irrigation by central pivot has been increased to 150%. The waters used for irrigation are sodium carbonates. The combination of irrigation and rain increases the sodium absorption ratio of soil (SARs), consequently raising the clay dispersion and reducing infiltration. This implies an increased risk of soil loss. A reduction in the development of white clover crop (Trifolium repens L.) was observed at an irrigation plot during 2015 campaign. The clover was planted in order to reduce the impact of two maize (Zea mays L.) campaigns under irrigation, which had increased soil SAR and deteriorated soil structure. SPOT-5 radiometric normalized difference vegetation index (NDVI) images were used to determine two zones of high and low production. In each zone, four random points were selected for further geo-referenced field sampling. Two geo-referenced measures of effective depth and surface soil sampling were carried out in each point. Texture of soil samples was determined by Pipette Method of Sedimentation Analysis. Data exploratory analysis showed that low production zone had a media effective depth = 80 cm and silty clay loam texture, while high production zone had a media effective depth > 140 cm and silt loam texture. The texture class of the low production zone did not correspond to prior soil studies carried out by the INTA (National Institute of Agricultural Technology), which showed that those soil textures were silt loam at surface and silty clay loam at sub-surface. The loss of the A horizon is proposed as a possible explanation, but further research is required. Besides, the need of a soil cartography actualization, which integrates new satellite imaging technologies and geo-referenced measurements with soil sensors is

  5. Urban vegetation detection using radiometrically calibrated small-footprint full-waveform airborne LiDAR data

    Science.gov (United States)

    Höfle, Bernhard; Hollaus, Markus; Hagenauer, Julian

    2012-01-01

    This paper introduces a new GIS workflow for urban vegetation mapping from high-density (50 pts./m 2) full-waveform airborne LiDAR data, combining the advantages of both raster and point cloud based analysis. Polygon segments derived by edge-based segmentation of the normalized digital surface model are used for classification. A rich set of segment features based on the point cloud and derived from full-waveform attributes is built, serving as input for a decision tree and artificial neural network (ANN) classifier. Exploratory data analysis and detailed investigation of the discriminative power of selected point cloud and full-waveform LiDAR observables indicate a high value of the occurrence of multiple distinct targets in a laser beam (i.e. 'echo ratio') for vegetation classification (98% correctness). The radiometric full-waveform observables (e.g. backscattering coefficient) do not suffice as single discriminators with low correctness values using a decision tree classifier (⩽72% correctness) but higher values with ANN (⩽95% correctness). Tests using reduced point densities indicate that the derived segment features and classification accuracies remain relatively stable even up to a reduction factor of 10 (5 pts./m 2). In a representative study area in the City of Vienna/Austria the applicability of the developed object-based GIS workflow is demonstrated. The unique high density full-waveform LiDAR data open a new scale in 3D object characterization but demands for novel joint strategies in object-based raster and 3D point cloud analysis.

  6. Hexabromocyclododecanes, polybrominated diphenyl ethers, and polychlorinated biphenyls in radiometrically dated sediment cores from English lakes, ~ 1950–present

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Congqiao, E-mail: congqiao.yang@utoronto.ca [School of Geography, Earth, and Environmental Sciences, University of Birmingham, Birmingham B15 2TT (United Kingdom); Rose, Neil L.; Turner, Simon D.; Yang, Handong; Goldsmith, Ben [Environmental Change Research Centre, Department of Geography, University College London, London WC1E 6BT (United Kingdom); Losada, Sara; Barber, Jonathan L. [Centre for Environment, Fisheries and Aquaculture Science, Cefas Lowestoft Laboratory, Pakefield Road, Lowestoft, Suffolk NR33 0HT (United Kingdom); Harrad, Stuart [School of Geography, Earth, and Environmental Sciences, University of Birmingham, Birmingham B15 2TT (United Kingdom)

    2016-01-15

    This paper reports input fluxes between ~ 1950 and present, of polychlorinated biphenyls (PCBs), polybrominated diphenyl ethers (PBDEs), and hexabromocyclododecanes (HBCDs) in radiometrically-dated sediment cores from 7 English lakes. Fluxes of PCBs at all but one location prone to significant sediment resuspension peaked in the late-1960s/early-1990s, before declining thereafter. Input fluxes of HBCDs at all sites increased from first emergence in the mid-1960s. Thereafter, fluxes peaked in the late-1980s/early-2000s, before declining through to the present, except at the most urban site where HBCD fluxes are still increasing. Trends of PBDEs predominant in the Penta-BDE and Octa-BDE formulations vary between sites. While at some locations, fluxes peaked in the late-1990s/early-2000s; at others, fluxes are still increasing. This suggests the full impact of EU restrictions on these formulations has yet to be felt. Fluxes of BDE-209 have yet to peak at all except one location, suggesting little discernible environmental response to recent EU restrictions on the Deca-BDE product. Strikingly, fluxes of BDE-209 in the most recent core slices either exceed or approach peak fluxes of ΣPCBs, implying substantial UK use of Deca-BDE. Excepting HBCDs, inventories of our target contaminants correlated significantly with local population density, implying substantial urban sources. - Highlights: • Temporal trends in PCB inputs consistent with those in UK manufacture & use. • HBCD inputs declining from peak levels at all but the most urban site. • Deca-BDE inputs yet to peak at all but one site. • Varying Penta & Octa-BDE trends imply full impact of restrictions not yet evident. • Excepting HBCDs, contaminant inventories correlate with local population density.

  7. Simultaneous retrieval of aerosol and surface optical properties from combined airborne- and ground-based direct and diffuse radiometric measurements

    Directory of Open Access Journals (Sweden)

    C. K. Gatebe

    2010-03-01

    Full Text Available This paper presents a new method for simultaneously retrieving aerosol and surface reflectance properties from combined airborne and ground-based direct and diffuse radiometric measurements. The method is based on the standard Aerosol Robotic Network (AERONET method for retrieving aerosol size distribution, complex index of refraction, and single scattering albedo, but modified to retrieve aerosol properties in two layers, below and above the aircraft, and parameters on surface optical properties from combined datasets (Cloud Absorption Radiometer (CAR and AERONET data. A key advantage of this method is the inversion of all available spectral and angular data at the same time, while accounting for the influence of noise in the inversion procedure using statistical optimization. The wide spectral (0.34–2.30 μm and angular range (180° of the CAR instrument, combined with observations from an AERONET sunphotometer, provide sufficient measurement constraints for characterizing aerosol and surface properties with minimal assumptions. The robustness of the method was tested on observations made during four different field campaigns: (a the Southern African Regional Science Initiative 2000 over Mongu, Zambia, (b the Intercontinental Transport Experiment-Phase B over Mexico City, Mexico (c Cloud and Land Surface Interaction Campaign over the Atmospheric Radiation Measurement (ARM Central Facility, Oklahoma, USA, and (d the Arctic Research of the Composition of the Troposphere from Aircraft and Satellites (ARCTAS over Elson Lagoon in Barrow, Alaska, USA. The four areas are dominated by different surface characteristics and aerosol types, and therefore provide good test cases for the new inversion method.

  8. The on-orbit performance of the Orbiting Carbon Observatory-2 (OCO-2) instrument and its radiometrically calibrated products

    Science.gov (United States)

    Crisp, David; Pollock, Harold R.; Rosenberg, Robert; Chapsky, Lars; Lee, Richard A. M.; Oyafuso, Fabiano A.; Frankenberg, Christian; O'Dell, Christopher W.; Bruegge, Carol J.; Doran, Gary B.; Eldering, Annmarie; Fisher, Brendan M.; Fu, Dejian; Gunson, Michael R.; Mandrake, Lukas; Osterman, Gregory B.; Schwandner, Florian M.; Sun, Kang; Taylor, Tommy E.; Wennberg, Paul O.; Wunch, Debra

    2017-01-01

    The Orbiting Carbon Observatory-2 (OCO-2) carries and points a three-channel imaging grating spectrometer designed to collect high-resolution, co-boresighted spectra of reflected sunlight within the molecular oxygen (O2) A-band at 0.765 microns and the carbon dioxide (CO2) bands at 1.61 and 2.06 microns. These measurements are calibrated and then combined into soundings that are analyzed to retrieve spatially resolved estimates of the column-averaged CO2 dry-air mole fraction, XCO2. Variations of XCO2 in space and time are then analyzed in the context of the atmospheric transport to quantify surface sources and sinks of CO2. This is a particularly challenging remote-sensing observation because all but the largest emission sources and natural absorbers produce only small ( 17 000), dynamic range (˜ 104), and sensitivity (continuum signal-to-noise ratio > 400). The OCO-2 instrument performance was extensively characterized and calibrated prior to launch. In general, the instrument has performed as expected during its first 18 months in orbit. However, ongoing calibration and science analysis activities have revealed a number of subtle radiometric and spectroscopic challenges that affect the yield and quality of the OCO-2 data products. These issues include increased numbers of bad pixels, transient artifacts introduced by cosmic rays, radiance discontinuities for spatially non-uniform scenes, a misunderstanding of the instrument polarization orientation, and time-dependent changes in the throughput of the oxygen A-band channel. Here, we describe the OCO-2 instrument, its data products, and its on-orbit performance. We then summarize calibration challenges encountered during its first 18 months in orbit and the methods used to mitigate their impact on the calibrated radiance spectra distributed to the science community.

  9. Radiometric Inter-Calibration between Himawari-8 AHI and S-NPP VIIRS for the Solar Reflective Bands

    Directory of Open Access Journals (Sweden)

    Fangfang Yu

    2016-02-01

    Full Text Available The Advanced Himawari Imager (AHI on-board Himawari-8, which was launched on 7 October 2014, is the first geostationary instrument housed with a solar diffuser to provide accurate onboard calibrated data for the visible and near-infrared (VNIR bands. In this study, the Ray-matching and collocated Deep Convective Cloud (DCC methods, both of which are based on incidently collocated homogeneous pairs between AHI and Suomi NPP (S-NPP Visible Infrared Imaging Radiometer Suite (VIIRS, are used to evaluate the calibration difference between these two instruments. While the Ray-matching method is used to examine the reflectance difference over the all-sky collocations with similar viewing and illumination geometries, the near lambertian collocated DCC pxiels are used to examine the difference for the median or high reflectance scenes. Strong linear relationships between AHI and VIIRS can be found at all the paired AHI and VIIRS bands. Results of both methods indicate that AHI radiometric calibration accuracy agrees well with VIIRS data within 5% for B1-4 and B6 at mid and high reflectance scenes, while AHI B5 is generally brighter than VIIRS by ~6%–8%. No apparent East-West viewing angle dependent calibration difference can be found at all the VNIR bands. Compared to the Ray-matching method, the collocated DCC method provides less uncertainty of inter-calibration results at near-infrared (NIR bands. As AHI has similar optics and calibration designs to the GOES-R Advanced Baseline Imager (ABI, which is currently scheduled to launch in fall 2016, the on-orbit AHI data provides a unique opportunity to develop, test and examine the cal/val tools developed for ABI.

  10. VNIR, MWIR, and LWIR source assemblies for optical quality testing and spectro-radiometric calibration of earth observation satellites

    Science.gov (United States)

    Compain, Eric; Maquet, Philippe; Leblay, Pierrick; Gavaud, Eric; Marque, Julien; Glastre, Wilfried; Cortese, Maxime; Sugranes, Pierre; Gaillac, Stephanie; Potheau, Hervé

    2015-09-01

    This document presents several original OGSEs, Optical Ground Support Equipment, specifically designed and realized for the optical testing and calibration of earth observation satellites operating in a large spectral band from 0.4μm to 14.7μm. This work has been mainly supported by recent development dedicated to MTG, Meteosat Third Generation, the ESA next generation of meteorological satellites. The improved measurement capabilities of this new satellite generation has generated new challenging requirements for the associated optical test equipments. These improvements, based on design and component innovation will be illustrated for the MOTA, the GICS and the DEA OGSEs. MOTA and GICS are dedicated to the AIT, Assembly Integration and Test, of FCI, the Flexible Combined Imager of the imaging satellite MTG-I. DEA OGSE is dedicated to the AIT of the DEA, Detection Electronics Assembly, which is part of IRS instrument, an IR sounder part of MTG-S satellite. From an architectural point of view, the presented original designs enable to run many optical tests with a single system thanks to a limited configuration effort. Main measurement capabilities are optical quality testing (MTF based mainly on KEF measurement), Line of Sight (LoS) stability measurement, straylight analyses, VNIR-MWIR-LWIR focal plane array co-registration, and broadband large dynamic spectro-radiometric calibration. Depending on the AIT phase of the satellite, these source assemblies are operated at atmospheric pressure or under secondary vacuum. In operation, they are associated with an opto-mechanical projection system that enables to conjugate the image of the source assembly with the focal plane of the satellite instruments. These conjugation systems are usually based on high resolution, broadband collimator, and are optionally mounted on hexapod to address the entire field of instruments.

  11. Radiometric calibration stability and inter-calibration of solar-band instruments in orbit using the moon

    Science.gov (United States)

    Stone, T.C.

    2008-01-01

    With the increased emphasis on monitoring the Earth's climate from space, more stringent calibration requirements are being placed on the data products from remote sensing satellite instruments. Among these are stability over decade-length time scales and consistency across sensors and platforms. For radiometer instruments in the solar reflectance wavelength range (visible to shortwave infrared), maintaining calibration on orbit is difficult due to the lack of absolute radiometric standards suitable for flight use. The Moon presents a luminous source that can be viewed by all instruments in Earth orbit. Considered as a solar diffuser, the lunar surface is exceedingly stable. The chief difficulty with using the Moon is the strong variations in the Moon's brightness with illumination and viewing geometry. This mandates the use of a photometric model to compare lunar observations, either over time by the same instrument or between instruments. The U.S. Geological Survey in Flagstaff, Arizona, under NASA sponsorship, has developed a model for the lunar spectral irradiance that explicitly accounts for the effects of phase, the lunar librations, and the lunar surface reflectance properties. The model predicts variations in the Moon's brightness with precision ???1% over a continuous phase range from eclipse to the quarter lunar phases. Given a time series of Moon observations taken by an instrument, the geometric prediction capability of the lunar irradiance model enables sensor calibration stability with sub-percent per year precision. Cross-calibration of instruments with similar passbands can be achieved with precision comparable to the model precision. Although the Moon observations used for intercomparison can be widely separated in phase angle and/or time, SeaWiFS and MODIS have acquired lunar views closely spaced in time. These data provide an example to assess inter-calibration biases between these two instruments.

  12. Liquidity risk management

    Directory of Open Access Journals (Sweden)

    Milošević Miloš

    2014-01-01

    Full Text Available Liquidity risk management is a major activity of every bank. To be able to honor its matured liabilities, a bank strives to provide and maintain the required level of liquidity on a daily basis. Although each commercial bank has its own methodology of calculating the required liquidity level, in line with its adopted policies, the central bank has enacted the Decision on Liquidity Risk Management, prescribing the obligatory liquidity risk management policy.

  13. Absolute Radiometric Calibration of the GÖKTÜRK-2 Satellite Sensor Using Tuz GÖLÜ (landnet Site) from Ndvi Perspective

    Science.gov (United States)

    Sakarya, Ufuk; Hakkı Demirhan, İsmail; Seda Deveci, Hüsne; Teke, Mustafa; Demirkesen, Can; Küpçü, Ramazan; Feray Öztoprak, A.; Efendioğlu, Mehmet; Fehmi Şimşek, F.; Berke, Erdinç; Zübeyde Gürbüz, Sevgi

    2016-06-01

    TÜBİTAK UZAY has conducted a research study on the use of space-based satellite resources for several aspects of agriculture. Especially, there are two precision agriculture related projects: HASSAS (Widespread application of sustainable precision agriculture practices in Southeastern Anatolia Project Region (GAP) Project) and AKTAR (Smart Agriculture Feasibility Project). The HASSAS project aims to study development of precision agriculture practice in GAP region. Multi-spectral satellite imagery and aerial hyperspectral data along with ground measurements was collected to analyze data in an information system. AKTAR aims to develop models for irrigation, fertilization and spectral signatures of crops in Inner Anatolia. By the end of the project precision agriculture practices to control irrigation, fertilization, pesticide and estimation of crop yield will be developed. Analyzing the phenology of crops using NDVI is critical for the projects. For this reason, absolute radiometric calibration of the Red and NIR bands in space-based satellite sensors is an important issue. The Göktürk-2 satellite is an earth observation satellite which was designed and built in Turkey and was launched in 2012. The Göktürk-2 satellite sensor has a resolution 2.5 meters in panchromatic and 5 meters in R/G/B/NIR bands. The absolute radiometric calibration of the Göktürk-2 satellite sensor was performed via the ground-based measurements - spectra-radiometer, sun photometer, and meteorological station- in Tuz Gölü cal/val site in 2015. In this paper, the first ground-based absolute radiometric calibration results of the Göktürk-2 satellite sensor using Tuz Gölü is demonstrated. The absolute radiometric calibration results of this paper are compared with the published cross-calibration results of the Göktürk-2 satellite sensor utilizing Landsat 8 imagery. According to the experimental comparison results, the Göktürk-2 satellite sensor coefficients for red and NIR bands

  14. ABSOLUTE RADIOMETRIC CALIBRATION OF THE GÖKTÜRK-2 SATELLITE SENSOR USING TUZ GÖLÜ (LANDNET SITE FROM NDVI PERSPECTIVE

    Directory of Open Access Journals (Sweden)

    U. Sakarya

    2016-06-01

    Full Text Available TÜBİTAK UZAY has conducted a research study on the use of space-based satellite resources for several aspects of agriculture. Especially, there are two precision agriculture related projects: HASSAS (Widespread application of sustainable precision agriculture practices in Southeastern Anatolia Project Region (GAP Project and AKTAR (Smart Agriculture Feasibility Project. The HASSAS project aims to study development of precision agriculture practice in GAP region. Multi-spectral satellite imagery and aerial hyperspectral data along with ground measurements was collected to analyze data in an information system. AKTAR aims to develop models for irrigation, fertilization and spectral signatures of crops in Inner Anatolia. By the end of the project precision agriculture practices to control irrigation, fertilization, pesticide and estimation of crop yield will be developed. Analyzing the phenology of crops using NDVI is critical for the projects. For this reason, absolute radiometric calibration of the Red and NIR bands in space-based satellite sensors is an important issue. The Göktürk-2 satellite is an earth observation satellite which was designed and built in Turkey and was launched in 2012. The Göktürk-2 satellite sensor has a resolution 2.5 meters in panchromatic and 5 meters in R/G/B/NIR bands. The absolute radiometric calibration of the Göktürk-2 satellite sensor was performed via the ground-based measurements - spectra-radiometer, sun photometer, and meteorological station- in Tuz Gölü cal/val site in 2015. In this paper, the first ground-based absolute radiometric calibration results of the Göktürk-2 satellite sensor using Tuz Gölü is demonstrated. The absolute radiometric calibration results of this paper are compared with the published cross-calibration results of the Göktürk-2 satellite sensor utilizing Landsat 8 imagery. According to the experimental comparison results, the Göktürk-2 satellite sensor coefficients for

  15. Post-launch Radiometric and Spectral Calibration Assessment of NPP/CrIS by Comparing CrIS with VIIRS, AIRS, and IASI

    OpenAIRE

    Wang, Likun; Han, Yong; Tremblay, Denis; Goldberg, Mitch

    2012-01-01

    The Cross-track Infrared Sounder (CrIS) on the newly-launched Suomi National Polar-orbiting Partnership (Suomi NPP) and future Joint Polar Satellite System (JPSS) is a Fourier transform spectrometer that provides soundings of the atmosphere with 1305 spectral channels, over 3 wavelength ranges: LWIR (9.14 - 15.38um); MWIR (5.71 - 8.26um); and SWIR (3.92 - 4.64 um). An accurate spectral and radiometric calibration is fundamental for CrIS radiance Sensor Data Records (SDRs). In this study, thro...

  16. Evidence of cracks in austenitic pipe weldings with a radiometric inspection system; Nachweis von Rissen in austenitischen Rohrleitungsnaehten mit einem radiometrischen Pruefsystem

    Energy Technology Data Exchange (ETDEWEB)

    Maier, H.J.; Wuensch, W. [Stuttgart Univ. (Germany). Staatliche Materialpruefungsanstalt

    1999-08-01

    The paper reports the development of a radiometric prototype device and its application to inspection of austenitic weldings with intercrystalline crack defects. The device initially was intended to be used for supplemental inspection for clarification of contradictory or unclear testing results, but the results obtained justify to consider the possibility of using it as an independent, full-scope testing instrument. (orig./CB) [Deutsch] Berichtet wird ueber die Entwicklung eines Prototypes eines Radiometrie-Geraetes zur Pruefung von austenitischen Schweissnaehten mit interkristalliner Rissbildung, zunaechst als Entscheidungshilfe bei unklaren bzw. sich widersprechenden Pruefresultaten. Zwischenzeitlich wird auch daran gedacht, ein solches Geraet fuer eine vollstaendige Pruefung weiter zu entwickeln. (orig./DGE)

  17. Radiometric Normalization of Temporal Images Combining Automatic Detection of Pseudo-Invariant Features from the Distance and Similarity Spectral Measures, Density Scatterplot Analysis, and Robust Regression

    Directory of Open Access Journals (Sweden)

    Ana Paula Ferreira de Carvalho

    2013-05-01

    Full Text Available Radiometric precision is difficult to maintain in orbital images due to several factors (atmospheric conditions, Earth-sun distance, detector calibration, illumination, and viewing angles. These unwanted effects must be removed for radiometric consistency among temporal images, leaving only land-leaving radiances, for optimum change detection. A variety of relative radiometric correction techniques were developed for the correction or rectification of images, of the same area, through use of reference targets whose reflectance do not change significantly with time, i.e., pseudo-invariant features (PIFs. This paper proposes a new technique for radiometric normalization, which uses three sequential methods for an accurate PIFs selection: spectral measures of temporal data (spectral distance and similarity, density scatter plot analysis (ridge method, and robust regression. The spectral measures used are the spectral angle (Spectral Angle Mapper, SAM, spectral correlation (Spectral Correlation Mapper, SCM, and Euclidean distance. The spectral measures between the spectra at times t1 and t2 and are calculated for each pixel. After classification using threshold values, it is possible to define points with the same spectral behavior, including PIFs. The distance and similarity measures are complementary and can be calculated together. The ridge method uses a density plot generated from images acquired on different dates for the selection of PIFs. In a density plot, the invariant pixels, together, form a high-density ridge, while variant pixels (clouds and land cover changes are spread, having low density, facilitating its exclusion. Finally, the selected PIFs are subjected to a robust regression (M-estimate between pairs of temporal bands for the detection and elimination of outliers, and to obtain the optimal linear equation for a given set of target points. The robust regression is insensitive to outliers, i.e., observation that appears to deviate

  18. Evidence of cracks in austenitic pipe weldings with a radiometric inspection system; Nachweis von Rissen in austenitischen Rohrleitungsnaehten mit einem radiometrischen Pruefsystem

    Energy Technology Data Exchange (ETDEWEB)

    Maier, H.J.; Wuensch, W. [Stuttgart Univ. (Germany). Staatliche Materialpruefungsanstalt

    1999-08-01

    The paper reports the development of a radiometric prototype device and its application to inspection of austenitic weldings with intercrystalline crack defects. The device initially was intended to be used for supplemental inspection for clarification of contradictory or unclear testing results, but the results obtained justify to consider the possibility of using it as an independent, full-scope testing instrument. (orig./CB) [Deutsch] Berichtet wird ueber die Entwicklung eines Prototypes eines Radiometrie-Geraetes zur Pruefung von austenitischen Schweissnaehten mit interkristalliner Rissbildung, zunaechst als Entscheidungshilfe bei unklaren bzw. sich widersprechenden Pruefresultaten. Zwischenzeitlich wird auch daran gedacht, ein solches Geraet fuer eine vollstaendige Pruefung weiter zu entwickeln. (orig./DGE)

  19. Radiometric evaluation of the {sup 210}Pb in the estuary of the SUAPE Pole in the State of Pernambuco

    Energy Technology Data Exchange (ETDEWEB)

    Carneiro, Paula Frassinetti P.; Antonio Filho, Joao; Mendonca, Keyla Mary C., E-mail: jaf@ufpe.com [Departamento de Energia Nuclear (DEN/UFPE), Recife, PE (Brazil); Carvalho, Wellington S. [Faculdade Integrada de Pernambuco (FACIPE), Recife, PE (Brazil)

    2011-07-01

    Nowadays there is a growing interest in the study of natural radioactivity levels, mainly of radionuclide {sup 210}Pb present in the environment. The environmental radioactivity control is of extreme importance for attainment of information on the exposition of humans and vegetables the potential sources in natural radioactive occurrences. Industrial processes involving mining and extraction and production of oil foster concentration of radionuclides, contributing to the occurrence of what is known as TENORM Technologically Enhanced Naturally Occurring Radioactive Material. This work aims to assess the environmental radiological impact on the Estuarine Region of the SUAPE Industrial Pole, due to the installation of an oil refinery and the consequent introduction on the environment of natural radioactive materials from other regions. For this, were determined the concentrations of {sup 210}Pb in samples de soil, sediments, roots and levels of fen and fishes in the region above reported, these data will serve of parameters of reference for a radiometric evaluation on future radioecology impacts caused by the functioning of the refinery of SUAPE oil. To determine the concentration of {sup 210}Pb was used the Ionic Resin Exchange method, for in such a way, the detector was used alpha-beta. Concentrations of {sup 210}Pb in the soils, sediments, roots and levels of fen samples vary respectively from 27 {+-} 2 to 60 {+-} 5, from 18 {+-} 5 to 60 {+-} 6, from 65 {+-} 2 to 117 {+-} 3, from 217 {+-} 6 to 239 {+-} 7 Bq.kg-1. Concentrations of the {sup 210}Pb in samples of some species of fish found in the studied region, such as Mullet, Salema, Catfish and Carapitinga, was also determined varying from 26 {+-} 11 to 62 {+-} 6 Bq.kg-1. The results obtained in the samples of soils, sediments, roots of fen e fishes showed that the concentrations of {sup 210}Pb in the environment are normal for the patterns of the area and are in accordance with data the found ones in literature

  20. Radiometric temperature measurements fundamentals

    CERN Document Server

    Zhang, Zhuomin M; Machin, Graham

    2009-01-01

    This book describes the theory of radiation thermometry, both at a primary level and for a variety of applications, such as in the materials processing industries and remote sensing. This book is written for those who will apply radiation thermometry in industrial practice; use radiation thermometers for scientific research; the radiation thermometry specialist in a national measurement institute; developers of radiation thermometers who are working to innovate products for instrument manufacturers, and developers of non-contact thermometry methods to address challenging thermometry problems.

  1. OLI Radiometric Calibration

    Science.gov (United States)

    Markham, Brian; Morfitt, Ron; Kvaran, Geir; Biggar, Stuart; Leisso, Nathan; Czapla-Myers, Jeff

    2011-01-01

    Goals: (1) Present an overview of the pre-launch radiance, reflectance & uniformity calibration of the Operational Land Imager (OLI) (1a) Transfer to orbit/heliostat (1b) Linearity (2) Discuss on-orbit plans for radiance, reflectance and uniformity calibration of the OLI

  2. Radiometric Dating in Geology.

    Science.gov (United States)

    Pankhurst, R. J.

    1980-01-01

    Described are several aspects and methods of quantitatively measuring geologic time using a constant-rate natural process of radioactive decay. Topics include half lives and decay constants, radiogenic growth, potassium-argon dating, rubidium-strontium dating, and the role of geochronology in support of geological exploration. (DS)

  3. Dynamics of liquid-liquid displacement.

    Science.gov (United States)

    Fetzer, Renate; Ramiasa, Melanie; Ralston, John

    2009-07-21

    Capillary driven liquid-liquid displacement in a system with two immiscible liquids of comparable viscosity was investigated by means of optical high speed video microscopy. For the first time, the impact of substrate wettability on contact line dynamics in liquid-liquid systems was studied. On all substrates, qualitatively different dynamics, in two distinct velocity regimes, were found. Hydrodynamic models apply to the fast stage of initial spreading, while nonhydrodynamic dissipation dominates contact line motion in a final stage at low speed, where the molecular kinetic theory (MKT) successfully captured the dynamics. The MKT model parameter values showed no systematic dependence on substrate wettability. This unexpected result is interpreted in terms of local contact line pinning.

  4. Liquid Effluent Retention Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Liquid Effluent Retention Facility (LERF) is located in the central part of the Hanford Site. LERF is permitted by the State of Washington and has three liquid...

  5. Liquid Drop Measuring Device for Analyzing Liquid Properties

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    Based on the correlation between certain properties of liquid and the properties of the corresponding liquid drop formed under given conditions, a liquid drop measuring device is utilized to monitor the drop formation process of the liquid sample with photoelectric measuring methods. The mechanical and optical characteristic of the liquid is explored with the optical fibers from the internal of the liquid drop during its formation. The drop head capacitor is utilized to monitor the growth process of the liquid drop to gain the drop volume information related to the physical property of liquid. The unique liquid drop trace containing the integrated properties of liquid is generated, and it is proved by experiment that for different liquids their liquid drop traces are different. The analysis on liquid properties and discrimination between different liquids can be proceeded with the liquid drop trace obtained by the liquid drop measuring device.

  6. Global Liquidity Trap

    OpenAIRE

    Fujiwara, Ippei; NAKAJIMA Tomoyuki; Sudo, Nao; Teranishi, Yuki

    2011-01-01

    In this paper we consider a two-country New Open Economy Macroeconomics model, and analyze the optimal monetary policy when countries cooperate in the face of a "global liquidity trap" -- i.e., a situation where the two countries are simultaneously caught in liquidity traps. The notable features of the optimal policy in the face of a global liquidity trap are history dependence and international dependence. The optimality of history dependent policy is confirmed as in local liquidity trap. A ...

  7. Asset Class Liquidity Risk

    OpenAIRE

    Ronnie Sadka

    2014-01-01

    This paper studies liquidity risk, as measured by the covariation of returns with unexpected changes in aggregate liquidity, across 106 indices covering global equity, industry sectors, fixed income, and hedge funds. Roughly 20% of all sample indices, and over 50% of hedge-fund indices, display a significant exposure to liquidity risk. The annualized cross-sectional liquidity risk premium is estimated at about 2%. The results are robust to various controls and methodological choices. Practica...

  8. Liquid Scintillation Counting of Environmental Radioisotopes: A Review of the Impact of Background Reduction

    Energy Technology Data Exchange (ETDEWEB)

    Douglas, Matthew; Bernacki, Bruce E.; Erchinger, Jennifer L.; Finn, Erin C.; Fuller, Erin S.; Hoppe, Eric W.; Keillor, Martin E.; Morley, Shannon M.; Mullen, Crystal A.; Orrell, John L.; Panisko, Mark E.; Warren, Glen A.; Wright, Michael E.

    2016-03-09

    Liquid scintillation counting (LSC) is a versatile and commonplace method for radiometric measurement of charged particle emitting radionuclides. The LSC method provides utility in a range of environmental science applications including hydrological studies of water transport, anthropogenic releases of radionuclides into the environment, and vertical mixing rates within oceans. Instrumental measurement background is one limiting factor of radiometric measurement sensitivity. As part of the development of a custom low background LSC system located in a shallow underground laboratory at Pacific Northwest National Laboratory, a number of measurement applications of LSC have been considered and are summarized here. The focus is on determining which aspects of such measurements would gain the greatest benefit from the reduction of LSC backgrounds by a factor of 10-100 relative to values reported in the literature. Examples of benefits include lowering the minimum detectable activity, reducing the sample size required, and shortening the elapsed timeline of the processing and analysis sequence. In particular tritium, strontium, and actinium isotopes are examined as these isotopes cover a range of requirements related to the LSC measurement method (e.g., 3H: low energy; Sr: spectral deconvolution; Ac: alpha/beta discrimination).

  9. Intracellular fate of Mycobacterium avium subspecies paratuberculosis in monocytes from normal and infected, interferon-responsive cows as determined by a radiometric method.

    Science.gov (United States)

    Zhao, B Y; Czuprynski, C J; Collins, M T

    1999-01-01

    The ability of Mycobacterium avium subsp. paratuberculosis to survive in bovine monocytes was studied using radiometric (BACTEC) culture, standard plate counting and microscopic counting of acid-fast stained monocyte monolayers. Results of microscopic counts sharply contrasted with results of viable counts determined both by plate counting and radiometric counting. We observed an early phase (the first 6 d after in vitro infection) of intracellular bacillary growth, followed by a later phase of mycobacteriostasis or killing (up to 12 d after in vitro infection) in monocytes from non-infected cows. The data suggest that multiplication and death of M. avium subsp. paratuberculosis occur simultaneously in bovine monocytes infected in vitro. Using the BACTEC method, we compared the ability of bovine monocytes from normal cows and cows infected with M. avium subsp. paratuberculosis and showing evidence of a strong Thl-like cellular immune response to ingest and inhibit the intracellular growth of M. avium subsp. paratuberculosis. There was a trend toward greater phagocytosis and faster killing of Mycobacterium avium subsp. paratuberculosis by monocytes from the infected, immune responder cows. However, the observed numbers of viable M. avium subsp. paratuberculosis at each time after monocyte infection were not significantly different between normal and infected cows.

  10. Radiometric Cross-Calibration of the Chilean Satellite FASat-C Using RapidEye and EO-1 Hyperion Data and a Simultaneous Nadir Overpass Approach

    Directory of Open Access Journals (Sweden)

    Carolina Barrientos

    2016-07-01

    Full Text Available The absolute radiometric calibration of a satellite sensor is the critical factor that ensures the usefulness of the acquired data for quantitative applications on remote sensing. This work presents the results of the first cross-calibration of the sensor on board the Sistema Satelital de Observación de la Tierra (SSOT Chilean satellite or Air Force Satellite FASat-C. RapidEye-MSI was chosen as the reference sensor, and a simultaneous Nadir Overpass Approach (SNO was applied. The biases caused by differences in the spectral responses of both instruments were compensated through an adjustment factor derived from EO-1 Hyperion data. Through this method, the variations affecting the radiometric response of New AstroSat Optical Modular Instrument (NAOMI-1, have been corrected based on collections over the Frenchman Flat calibration site. The results of a preliminary evaluation of the pre-flight and updated coefficients have shown a significant improvement in the accuracy of at-sensor radiances and TOA reflectances: an average agreement of 2.63% (RMSE was achieved for the multispectral bands of both instruments. This research will provide a basis for the continuity of calibration and validation tasks of future Chilean space missions.

  11. Spectrally and Radiometrically Stable Wide-Band on Board Calibration Source for In-Flight Data Validation in Imaging Spectroscopy Applications

    Science.gov (United States)

    Coles, J. B.; Richardson, Brandon S.; Eastwood, Michael L.; Sarture, Charles M.; Quetin, Gregory R.; Hernandez, Marco A.; Kroll, Linley A.; Nolte, Scott H.; Porter, Michael D.; Green, Robert O.

    2011-01-01

    The quality of the quantitative spectral data collected by an imaging spectrometer instrument is critically dependent upon the accuracy of the spectral and radiometric calibration of the system. In order for the collected spectra to be scientifically useful, the calibration of the instrument must be precisely known not only prior to but during data collection. Thus, in addition to a rigorous in-lab calibration procedure, the airborne instruments designed and built by the NASA/JPL Imaging Spectroscopy Group incorporate an on board calibrator (OBC) system with the instrument to provide auxiliary in-use system calibration data. The output of the OBC source illuminates a target panel on the backside of the foreoptics shutter both before and after data collection. The OBC and in-lab calibration data sets are then used to validate and post-process the collected spectral image data. The resulting accuracy of the spectrometer output data is therefore integrally dependent upon the stability of the OBC source. In this paper we describe the design and application of the latest iteration of this novel device developed at NASA/JPL which integrates a halogen-cycle source with a precisely designed fiber coupling system and a fiber-based intensity monitoring feedback loop. The OBC source in this Airborne Testbed Spectrometer was run over a period of 15 hours while both the radiometric and spectral stabilities of the output were measured and demonstrated stability to within 1% of nominal.

  12. An in vitro study of dental enamel wear by restorative materials using radiometric method; Estudo in vitro do desgaste do esmalte dental pelos materiais restauradores utilizando metodo radiometrico

    Energy Technology Data Exchange (ETDEWEB)

    Adachi, Lena Katekawa

    2000-07-01

    There is an increasing demand and interest to study the dental materials wear as well as about the abrasion effect on antagonistic teeth. Due to the fact that the existent restorative materials have no specifications about their abrasiveness, it is necessary the establishment of degrees of comparison among them to support clinical application. In this work, the radiometric method was applied to study the enamel wear caused by another enamel and by restorative materials (Ceramco II, Noritake and Finesse porcelains, Artglass and Targis). The dental enamel made radioactive by irradiation at the IEA-R1m nuclear research reactor under a thermal neutron flux was submitted to wear in a machine which allows sliding motion of an antagonistic surface in contact with this radioactive enamel. The enamel wear was evaluated by measuring beta activity of {sup 32}P transferred to water from this irradiated tooth. Results obtained indicated that dental porcelains cause pronounced enamel wear when compared with that provoked by another enamel or by resin materials. Resin materials caused less enamel wear than another enamel. Vickers microhardness data obtained for antagonistic materials showed a correlation with the wear caused to the enamel. This study allowed to conclude that the radiometric method proposed can be used satisfactorily in the evaluation of enamel wear by restorative materials. This method presents advantages due to quick responses and ease of analyses There is (author)

  13. Radiometric Cross Calibration of Landsat 8 Operational Land Imager (OLI and Landsat 7 Enhanced Thematic Mapper Plus (ETM+

    Directory of Open Access Journals (Sweden)

    Nischal Mishra

    2014-12-01

    Full Text Available This study evaluates the radiometric consistency between Landsat-8 Operational Land Imager (OLI and Landsat 7 Enhanced Thematic Mapper Plus (ETM+ using cross calibration techniques. Two approaches are used, one based on cross calibration between the two sensors using simultaneous image pairs, acquired during an underfly event on 29–30 March 2013. The other approach is based on using time series of image statistics acquired by these two sensors over the Libya 4 pseudo invariant calibration site (PICS (+28.55°N, +23.39°E. Analyses from these approaches show that the reflectance calibration of OLI is generally within ±3% of the ETM+ radiance calibration for all the reflective bands from visible to short wave infrared regions when the ChKur solar spectrum is used to convert the ETM+ radiance to reflectance. Similar results are obtained comparing the OLI radiance calibration directly with the ETM+ radiance calibration and the results in these two different physical units (radiance and reflectance agree to within ±2% for all the analogous bands. These results will also be useful to tie all the Landsat heritage sensors from Landsat 1 MultiSpectral Scanner (MSS through Landsat-8 OLI to a consistent radiometric scale.

  14. Calibration chain design based on integrating sphere transfer radiometer for SI-traceable on-orbit spectral radiometric calibration and its uncertainty analysis

    Science.gov (United States)

    Zhao, Wei-Ning; Fang, Wei; Sun, Li-Wei; Cui, Li-Hong; Wang, Yu-Peng

    2016-09-01

    In order to satisfy the requirement of SI-traceable on-orbit absolute radiation calibration transfer with high accuracy for satellite remote sensors, a transfer chain consisting of a fiber coupling monochromator (FBM) and an integrating sphere transfer radiometer (ISTR) was designed in this paper. Depending on the Sun, this chain based on detectors provides precise spectral radiometric calibration and measurement to spectrometers in the reflective solar band (RSB) covering 300-2500 nm with a spectral bandwidth of 0.5-6 nm. It shortens the traditional chain based on lamp source and reduces the calibration uncertainty from 5% to 0.5% by using the cryogenic radiometer in space as a radiometric benchmark and trap detectors as secondary standard. This paper also gives a detailed uncertainty budget with reasonable distribution of each impact factor, including the weak spectral signal measurement with uncertainty of 0.28%. According to the peculiar design and comprehensive uncertainty analysis, it illustrates that the spectral radiance measurement uncertainty of the ISTR system can reach to 0.48%. The result satisfies the requirements of SI-traceable on-orbit calibration and has wider significance for expanding the application of the remote sensing data with high-quality. Project supported by the National Natural Science Foundation of China (Grant No. 41474161) and the National High-Technology Program of China (Grant No. 2015AA123703).

  15. Radiometric quality and performance of TIMESAT for smoothing moderate resolution imaging spectroradiometer enhanced vegetation index time series from western Bahia State, Brazil

    Science.gov (United States)

    Borges, Elane F.; Sano, Edson E.; Medrado, Euzébio

    2014-01-01

    The launch of the Moderate Resolution Imaging Spectroradiometer (MODIS) sensor aboard the Terra and Aqua platforms in 1999 and 2002, respectively, with temporal resolutions of 1 to 2 days opened the possibility of using a longtime series of satellite images to map land use and land cover classes from different regions of the Earth, to study vegetation phenology, and to monitor regional and global climate change, among other applications. The main objectives of this study were twofold: to analyze the radiometric quality of the time series of enhanced vegetation index (EVI) products derived from the Terra MODIS sensor in western Bahia State, Brazil, and to identify the most appropriate filter to smooth MODIS EVI time series of the study area among those available in the public domain, the TIMESAT algorithm. The 2000 to 2011 time period was considered (a total of 276 scenes). The radiometric quality was analyzed based on the pixel reliability data set available in the MOD13Q1 product. The performances of the three smoothing filters available within TIMESAT (double logistic, Savitzky-Golay, and asymmetric Gaussian) were analyzed using the Graybill's F test and Willmott statistics. Five percent of the MODIS pixels from the study area were cloud-affected, almost all of which were from the rainy season. The double logistic filter presented the best performance.

  16. Spectrally and Radiometrically Stable Wide-Band on Board Calibration Source for In-Flight Data Validation in Imaging Spectroscopy Applications

    Science.gov (United States)

    Coles, J. B.; Richardson, Brandon S.; Eastwood, Michael L.; Sarture, Charles M.; Quetin, Gregory R.; Hernandez, Marco A.; Kroll, Linley A.; Nolte, Scott H.; Porter, Michael D.; Green, Robert O.

    2011-01-01

    The quality of the quantitative spectral data collected by an imaging spectrometer instrument is critically dependent upon the accuracy of the spectral and radiometric calibration of the system. In order for the collected spectra to be scientifically useful, the calibration of the instrument must be precisely known not only prior to but during data collection. Thus, in addition to a rigorous in-lab calibration procedure, the airborne instruments designed and built by the NASA/JPL Imaging Spectroscopy Group incorporate an on board calibrator (OBC) system with the instrument to provide auxiliary in-use system calibration data. The output of the OBC source illuminates a target panel on the backside of the foreoptics shutter both before and after data collection. The OBC and in-lab calibration data sets are then used to validate and post-process the collected spectral image data. The resulting accuracy of the spectrometer output data is therefore integrally dependent upon the stability of the OBC source. In this paper we describe the design and application of the latest iteration of this novel device developed at NASA/JPL which integrates a halogen-cycle source with a precisely designed fiber coupling system and a fiber-based intensity monitoring feedback loop. The OBC source in this Airborne Testbed Spectrometer was run over a period of 15 hours while both the radiometric and spectral stabilities of the output were measured and demonstrated stability to within 1% of nominal.

  17. Fluid Mechanics of Liquid-Liquid Systems.

    Science.gov (United States)

    Richards, John Reed

    The detailed hydrodynamics of selected liquid -liquid flow systems are investigated to provide a firm foundation for the rational design of separation processes. The implementation of this objective centers on the development of a robust code to simulate liquid-liquid flows. We have applied this code to the realistic simulation of aspects of the complex fluid mechanical behavior, and developed quantitative insight into the underlying processes involved. The Volume of Fluid (VOF) method is combined with the Continuous Surface Force (CSF) algorithm to provide a numerically stable code capable of solving high Reynolds numbers free surface flows. One of the developments during the testing was an efficient method for solving the Young-Laplace equation describing the shape of the meniscus in a vertical cylinder for a constrained liquid volume. The steady-state region near the nozzle for the laminar flow of a Newtonian liquid jet injected vertically into another immiscible Newtonian liquid is investigated for various Reynolds numbers by solving the axisymmetric transient equations of motion and continuity. The analysis takes into account pressure, viscous, inertial, gravitational, and surface tension forces, and comparison with previous experimental measurements shows good agreement. Comparisons of the present numerical method with the numerical results of previous boundary-layer methods help establish their range of validity. A new approximate equation for the shape of the interface of the steady jet, based on an overall momentum balance, is also developed. The full transient from liquid-liquid jet startup to breakup into drops is also simulated numerically. In comparison with experiment, the results of the present numerical method show a greater sensitivity of the jet length to the Reynolds number than the best predictions of previous linear stability analyses. The formation of drops is investigated at low to high Reynolds numbers before and after jet formation. The

  18. Investigating the influence of radiometric calibration on tree species determination based on small footprint full-waveform airborne LiDAR

    Science.gov (United States)

    Mücke, W.; Briese, C.; Hollaus, M.; Pfeifer, N.; Wagner, W.

    2013-12-01

    Small footprint airborne LiDAR is a well-established measurement technique in forestry, where cost- and time efficient wide-area data acquisition of the vegetation structure is required. Gathering stand-based information about tree species composition is of particular interest for forestry applications. Modern LiDAR systems provide, next to the acquired 3D (i.e. geometric) information, also a quantification of the signal strength of each echo. In order to utilize this information for tree species determination independently from different overlapping LiDAR swaths, different LiDAR sensors or acquisition times, radiometric calibration is a necessity. This contribution summarises the theoretical background of radiometric LiDAR data calibration on the physical basis of the radar equation. Using LiDAR observations of reference targets with known reflectivity the so-called calibration constant is computed. It accounts for sensor specific parameters, as well as atmospheric attenuation of the laser signal. Hence the backscatter properties of the laser echoes can be determined and physical observables characterizing the reflectivity of the scanned surface can be estimated. A practical calibration workflow is demonstrated on the example of a single wavelength full-waveform LiDAR data set from a mixed woodland in Austria. Subsequently, an automated method for tree species determination that is based on the laser light scattering mechanisms in the forest canopy is applied on both (calibrated and un-calibrated) data sets. First, an edge-based segmentation approach is used to aggregate LiDAR echoes to segments representing single tree crowns. Second, metrics are computed for each tree crown describing radiometric and geometric features that are related to foliage composition. Third, these metrics are used in a knowledge-based fuzzy classification scheme for the determination of segments representing coniferous and deciduous trees. Influences of the radiometric calibration on the

  19. Liquid/liquid/solid contact angles

    Science.gov (United States)

    Borocco, Marine; Pellet, Charlotte; Authelin, Jean-René; Clanet, Christophe; Quéré, David; Compagnie des Interfaces Team

    2016-11-01

    Many studies have investigated solid/liquid/air interfaces and their corresponding wetting properties. We discuss what happens in less-studied liquid/liquid/solid systems, and focus on questions of dynamical wetting in a tube, having in mind applications in detergency. We use a capillary tube filled with water and containing a slug of silicone oil (or vice-versa), and present a series of experiments to determine static and dynamic wetting properties corresponding to this situation. We also discuss interfacial aging of such systems.

  20. The effect of radiometer placement and view on inferred directional and hemispheric radiometric temperatures of an urban canopy

    Science.gov (United States)

    Adderley, C.; Christen, A.; Voogt, J. A.

    2015-07-01

    Any radiometer at a fixed location has a biased view when observing a convoluted, three-dimensional surface such as an urban canopy. The goal of this contribution is to determine the bias of various sensors views observing a simple urban residential neighbourhood (nadir, oblique, hemispherical) over a 24 hour cycle under clear weather conditions. The error in measuring a longwave radiation flux density (L) and/or inferring surface temperatures (T0) is quantified for different times over a diurnal cycle. Panoramic time-sequential thermography (PTST) data were recorded by a thermal camera on a hydraulic mast above a residential canyon in Vancouver, BC. The data set resolved sub-facet temperature variability of all representative urban facets in a 360° swath repetitively over a 24-hour cycle. This data set is used along with computer graphics and vision techniques to project measured fields of L for a given time and pixel onto texture sheets of a three-dimensional urban surface model at a resolution of centimetres. The resulting data set attributes L of each pixel on the texture sheets to different urban facets and associates facet location, azimuth, slope, material, and sky view factor. The texture sheets of L are used to calculate the complete surface temperature (T0,C) and to simulate the radiation in the field of view (FOV) of narrow and hemispheric radiometers observing the same urban surface (in absence of emissivity and atmospheric effects). The simulated directional (T0,d) and hemispheric (T0,h) radiometric temperatures inferred from various biased views are compared to T0,C. For a range of simulated off-nadir (φ) and azimuth (Ω) angles, T0,d(φ,Ω) and T0,C differ between -2.6 and +2.9 K over the course of the day. The effects of effective anisotropy are highest in the daytime, particularly around sunrise and sunset when different views can lead to differences in T0,d(φ,Ω) that are as high as 3.5 K. For a sensor with a narrow FOV in the nadir of the

  1. The effect of radiometer placement and view on inferred directional and hemispheric radiometric temperatures of a urban canopy

    Science.gov (United States)

    Adderley, C.; Christen, A.; Voogt, J. A.

    2015-02-01

    Any radiometer at a fixed location has a biased view when observing a convoluted, three dimensional surface such as an urban canopy. The goal of this contribution is to determine the bias of various sensors views observing a simple urban residential neighbourhood (nadir, oblique, hemispherical) over a 24 h cycle under clear weather conditions. The error in measuring longwave radiance (L) and/or inferring surface temperatures (T0) is quantified for different times over a diurnal cycle. Panoramic time-sequential thermography (PTST) data was recorded by a thermal camera on a hydraulic mast above a residential canyon in Vancouver, BC. The dataset resolved sub-facet temperature variability of all representative urban facets in a 360° swath repetitively over a 24 h cycle. This dataset is used along with computer graphics and vision techniques to project measured fields of L for a given time and pixel onto texture sheets of a three-dimensional urban surface model at a resolution of centimetres. The resulting dataset attributes L of each pixel on the texture sheets to different urban facets and associates facet location, azimuth, slope, material, and sky view factor. The texture sheets of L are used to calculate the complete surface temperature (T0,C) and to simulate the instantaneous field of view (IFOV) of narrow and hemispheric radiometers observing the same urban surface (in absence of emissivity and atmospheric effects). The simulated directional (T0,d) and hemispheric (T0,h) radiometric temperatures inferred from various biased views are compared to T0,C. For a range of simulated off-nadir (ϕ) and azimuth (Ω) angles, T0,d (ϕ, Ω) and T0,C differ between -2.7 and +2.9 K over the course of the day. The effects of effective anisotropy are highest in the daytime, particularly around sunrise and sunset when different views can lead to differences in T0,d (ϕ, Ω) that are as high as 3.5 K. For a sensor with a narrow IFOV in the nadir of the urban

  2. The effect of radiometer placement and view on inferred directional and hemispheric radiometric temperatures of a urban canopy

    Directory of Open Access Journals (Sweden)

    C. Adderley

    2015-02-01

    Full Text Available Any radiometer at a fixed location has a biased view when observing a convoluted, three dimensional surface such as an urban canopy. The goal of this contribution is to determine the bias of various sensors views observing a simple urban residential neighbourhood (nadir, oblique, hemispherical over a 24 h cycle under clear weather conditions. The error in measuring longwave radiance (L and/or inferring surface temperatures (T0 is quantified for different times over a diurnal cycle. Panoramic time-sequential thermography (PTST data was recorded by a thermal camera on a hydraulic mast above a residential canyon in Vancouver, BC. The dataset resolved sub-facet temperature variability of all representative urban facets in a 360° swath repetitively over a 24 h cycle. This dataset is used along with computer graphics and vision techniques to project measured fields of L for a given time and pixel onto texture sheets of a three-dimensional urban surface model at a resolution of centimetres. The resulting dataset attributes L of each pixel on the texture sheets to different urban facets and associates facet location, azimuth, slope, material, and sky view factor. The texture sheets of L are used to calculate the complete surface temperature (T0,C and to simulate the instantaneous field of view (IFOV of narrow and hemispheric radiometers observing the same urban surface (in absence of emissivity and atmospheric effects. The simulated directional (T0,d and hemispheric (T0,h radiometric temperatures inferred from various biased views are compared to T0,C. For a range of simulated off-nadir (ϕ and azimuth (Ω angles, T0,d (ϕ, Ω and T0,C differ between −2.7 and +2.9 K over the course of the day. The effects of effective anisotropy are highest in the daytime, particularly around sunrise and sunset when different views can lead to differences in T0,d (ϕ, Ω that are as high as 3.5 K. For a sensor with a narrow IFOV in the nadir of the

  3. Liquid Wall Chambers

    Energy Technology Data Exchange (ETDEWEB)

    Meier, W R

    2011-02-24

    The key feature of liquid wall chambers is the use of a renewable liquid layer to protect chamber structures from target emissions. Two primary options have been proposed and studied: wetted wall chambers and thick liquid wall (TLW) chambers. With wetted wall designs, a thin layer of liquid shields the structural first wall from short ranged target emissions (x-rays, ions and debris) but not neutrons. Various schemes have been proposed to establish and renew the liquid layer between shots including flow-guiding porous fabrics (e.g., Osiris, HIBALL), porous rigid structures (Prometheus) and thin film flows (KOYO). The thin liquid layer can be the tritium breeding material (e.g., flibe, PbLi, or Li) or another liquid metal such as Pb. TLWs use liquid jets injected by stationary or oscillating nozzles to form a neutronically thick layer (typically with an effective thickness of {approx}50 cm) of liquid between the target and first structural wall. In addition to absorbing short ranged emissions, the thick liquid layer degrades the neutron flux and energy reaching the first wall, typically by {approx}10 x x, so that steel walls can survive for the life of the plant ({approx}30-60 yrs). The thick liquid serves as the primary coolant and tritium breeding material (most recent designs use flibe, but the earliest concepts used Li). In essence, the TLW places the fusion blanket inside the first wall instead of behind the first wall.

  4. Acidic Ionic Liquids.

    Science.gov (United States)

    Amarasekara, Ananda S

    2016-05-25

    Ionic liquid with acidic properties is an important branch in the wide ionic liquid field and the aim of this article is to cover all aspects of these acidic ionic liquids, especially focusing on the developments in the last four years. The structural diversity and synthesis of acidic ionic liquids are discussed in the introduction sections of this review. In addition, an unambiguous classification system for various types of acidic ionic liquids is presented in the introduction. The physical properties including acidity, thermo-physical properties, ionic conductivity, spectroscopy, and computational studies on acidic ionic liquids are covered in the next sections. The final section provides a comprehensive review on applications of acidic ionic liquids in a wide array of fields including catalysis, CO2 fixation, ionogel, electrolyte, fuel-cell, membrane, biomass processing, biodiesel synthesis, desulfurization of gasoline/diesel, metal processing, and metal electrodeposition.

  5. Critical Phenomena in Liquid-Liquid Mixtures

    Science.gov (United States)

    Jacobs, D. T.

    2000-04-01

    Critical phenomena provide intriguing and essential insight into many issues in condensed matter physics because of the many length scales involved. Large density or concentration fluctuations near a system's critical point effectively mask the identity of the system and produce universal phenomena that have been well studied in simple liquid-vapor and liquid-liquid systems. Such systems have provided useful model systems to test theoretical predictions which can then be extended to more complicated systems. Along various thermodynamic paths, several quantities exhibit a simple power-law dependence close to the critical point. The critical exponents describing these relationships are universal and should depend only on a universality class determined by the order-parameter and spatial dimensionality of the system. Liquid gas, binary fluid mixtures, uniaxial ferromagnetism, polymer-solvent, and protein solutions all belong to the same (Ising model) universality class. The diversity of critical systems that can be described by universal relations indicates that experimental measurements on one system should yield the same information as on another. Our experimental investigations have tested existing theory and also extended universal behavior into new areas. By measuring the coexistence curve, heat capacity, thermal expansion and static light scattering (turbidity) in various liquid-liquid and polymer-solvent systems, we have determined critical exponents and amplitudes that have sometimes confirmed and other times challenged current theory. Recent experiments investigating the heat capacity and light scattering in a liquid-liquid mixture very close to the critical point will be discussed. This research is currently supported by The Petroleum Research Fund and by NASA grant NAG8-1433 with some student support from NSF-DMR 9619406.

  6. Comparison of agar dilution, broth microdilution, disk diffusion, E-test, and BACTEC radiometric methods for antimicrobial susceptibility testing of clinical isolates of the Nocardia asteroides complex.

    Science.gov (United States)

    Ambaye, A; Kohner, P C; Wollan, P C; Roberts, K L; Roberts, G D; Cockerill, F R

    1997-01-01

    An evaluation was undertaken to determine the optimal method for the in vitro susceptibility testing of 26 Nocardia asteroides complex isolates to the following antimicrobial agents: amikacin, ampicillin, amoxicillin-clavulanate, ceftriaxone, ciprofloxacin, erythromycin, imipenem, minocycline, and trimethoprim-sulfamethoxazole. Five testing methods were studied including the agar dilution, broth microdilution, and disk diffusion methods, the epsilometer test (E-test), and the BACTEC radiometric method. Results for each antimicrobial agent and each testing method were interpreted as indicating susceptibility, intermediate susceptibility, or resistance according to current guidelines of the National Committee for Clinical Laboratory Standards (NCCLS) for bacteria that grow aerobically and were then compared to a "gold standard" susceptibility test result. The gold standard result for each Nocardia isolate was established by a consensus of the results of the majority of testing methods used in the study. When the results were combined for all antimicrobial agents tested against all Nocardia isolates by all methods, the BACTEC radiometric method produced the highest level of agreement (97.9%) with the consensus results and had the fewest very major (n = 1), major (n = 2), and minor (n = 2) errors. In contrast, the results of the agar dilution method were in least agreement (93.2%) with the consensus results, and this method also produced the most very major (n = 8), major (n = 4), and, along with the disk diffusion method, minor (n = 6) errors. For all test methods, interpretive errors were most frequent when testing ampicillin or amoxicillin-clavulanate. Moreover, for all Nocardia nova isolates tested, ampicillin susceptibility results by any of the testing methods were not in agreement with the results of testing for beta-lactamase by the nitrocefin (Cefinase) disk method. We conclude that among the methods evaluated, the BACTEC radiometric method appeared to be the

  7. Determination of {sup 226}Ra and {sup 228}Ra in water by using liquid scintillation spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Mingote, Raquel Maia; Gomes, Nilton Carlos [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil). Servico de Quimica e Radioquimica], E-mail: mingote@cdtn.br; Gomes, Lorena Pedrosa; Menezes, Maria Angela de B.C. [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil). Servico de Reator e Irradiacoes

    2007-07-01

    A procedure for the determination of {sup 226}Ra and {sup 228}Ra in water samples by using liquid scintillation spectrometry was applied. The chemical separation of radium as Ba(Ra)SO{sub 4} was performed by the usual method of coprecipitation with barium carrier. The precipitated was mixed with water, Instagel{sup TM} and Ultima Gold AB{sup TM} scintillation cocktails after the delay time for {sup 226}Ra/{sup 222}Rn radioactive equilibrium. Activities of {sup 226}Ra and {sup 228}Ra were inferred from the alpha and beta counting respectively. It was used the pulse shape analyzer and correction factors for minimizing mutual radiometric interferences. The combined standard uncertainties were evaluated using the law of uncertainty propagation by partial derivatives method. The difficulties of method are discussed. (author)

  8. Solid on liquid deposition

    Energy Technology Data Exchange (ETDEWEB)

    Charmet, J., E-mail: jerome.charmet@he-arc.c [Institut des Microtechnologies Appliquees ARC, HES-SO Arc, Eplatures-Grise 17, 2300 La Chaux-de-Fonds (Switzerland); Banakh, O.; Laux, E.; Graf, B.; Dias, F.; Dunand, A.; Keppner, H. [Institut des Microtechnologies Appliquees ARC, HES-SO Arc, Eplatures-Grise 17, 2300 La Chaux-de-Fonds (Switzerland); Gorodyska, G.; Textor, M. [BioInterface group, ETHZ, Wolfgang-Pauli-Strasse 10, ETH Hoenggerberg HCI H 525 8093 Zuerich (Switzerland); Noell, W.; Rooij, N.F. de [Ecole Polytechnique Federale de Lausanne, Institute of Microengineering, Sensors, Actuators and Microsystems laboratory, Rue Jaquet Droz 1, 2000 Neuchatel (Switzerland); Neels, A.; Dadras, M.; Dommann, A.; Knapp, H. [Centre Suisse d' Electronique et de Microtechnique SA, Rue Jacquet-Droz 1, 2002 Neuchatel (Switzerland); Borter, Ch.; Benkhaira, M. [COMELEC SA, Rue de la Paix 129, 2300 La Chaux-de-Fonds (Switzerland)

    2010-07-01

    A process for the deposition of a solid layer onto a liquid is presented. The polymer poly-di-chloro-para-xylylene, also known as Parylene C, was grown on low vapour pressure liquids using the conventional low pressure chemical vapour deposition process. A reactor was built and a process developed to enable the deposition of Parylene C at atmospheric pressure over high vapour pressure liquids. It was used to deposit Parylene C over water among others. In all cases Parylene C encapsulated the liquid without influencing its initial shape. The results presented here show also that the Parylene C properties are not affected by its growth on liquid templates and the roughness of the Parylene C surface in contact with the liquid during the deposition is extremely low.

  9. LIQUID CYCLONE CONTACTOR

    Science.gov (United States)

    Whatley, M.E.; Woods, W.M.

    1962-09-01

    This invention relates to liquid-liquid extraction systems. The invention, an improved hydroclone system, comprises a series of serially connected, axially aligned hydroclones, each of which is provided with an axially aligned overflow chamber. The chambers are so arranged that rotational motion of a fluid being passed through the system is not lost in passing from chamber to chamber; consequently, this system is highly efficient in contacting and separating two immiscible liquids. (AEC)

  10. ROMANIAN BANKS LIQUIDITY MANAGEMENT

    Directory of Open Access Journals (Sweden)

    BATRANCEA MARIA

    2013-07-01

    Full Text Available Most transactions or financial commitments have implications for a bank liquidity. Transactions are particularly vulnerable to liquidity problems at a specific institution. Therefore, one can deduce the importance of the correct calculation and liquidity indicator, not only for the bank concerned, but especially for NBR uses that bank risk management tool. That is why the authors took into consideration a sample of banks in Romania to show to what extent the banking crisis has influenced the development banks.

  11. Harvesting contaminants from liquid

    Energy Technology Data Exchange (ETDEWEB)

    Simpson, John T.; Hunter, Scott R.

    2016-05-31

    Disclosed are examples of apparatuses for evaporative purification of a contaminated liquid. In each example, there is a vessel for storing the contaminated fluid. The vessel includes a surface coated with a layer of superhydrophobic material and the surface is at least partially in contact with the contaminated liquid. The contaminants do not adhere to the surface as the purified liquid evaporates, thus allowing the contaminants to be harvested.

  12. Parallel artificial liquid membrane extraction

    DEFF Research Database (Denmark)

    Gjelstad, Astrid; Rasmussen, Knut Einar; Parmer, Marthe Petrine

    2013-01-01

    This paper reports development of a new approach towards analytical liquid-liquid-liquid membrane extraction termed parallel artificial liquid membrane extraction. A donor plate and acceptor plate create a sandwich, in which each sample (human plasma) and acceptor solution is separated by an arti...... by an artificial liquid membrane. Parallel artificial liquid membrane extraction is a modification of hollow-fiber liquid-phase microextraction, where the hollow fibers are replaced by flat membranes in a 96-well plate format....

  13. Geology, tephrochronology, radiometric ages, and cross sections of the Mark West Springs 7.5 degree quadrangle, Sonoma and Napa counties, California

    Science.gov (United States)

    McLaughlin, R.J.; Sarna-Wojicki, A. M.; Fleck, R.J.; Wright, W.H.; Levin, V.R.G.; Valin, Z.C.

    2004-01-01

    This geologic map database and cross sections presents new geologic mapping by the authors in addition to new radiometric ages and tephrochronology of volcanic rock units. The map database depicts the general distribution of bedrock and surficial deposits in the mapped area and provides a context for interpreting the evolution of active faults in the region. Together with the accompanying PDF file (SIM2858-pamphlet.pdf), it provides current information on the geologic structure and stratigraphy of the area covered. The database delineates map units that are identified by general age and lithology following the stratigraphic nomenclature of the U.S. Geological Survey. The scale of the source maps limits the spatial resolution (scale) of the database to 1:24,000 or smaller.

  14. Radiometric Dating of Ignimbrite from Inner Mongolia Provides no Indication of a Post-Middle Jurassic Age for the Daohugou Beds

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    Lacustrine deposits exposed at Daohugou, Inner Mongolia, China, have yielded superbly preserved vertebrate fossils. The fossil beds were first misinterpreted as of Early Cretaceous age, based on alleged occurrences of key fossils of the Jehol Biota. Compelling evidence revealed by more rigorous research involving regional biostratigraphy, radiometric dating, and paleontology supports the Middle Jurassic age of the fossil beds. Despite the awesome evidence for the Middle Jurassic age of the Daohugou beds, the age dispute has been resurrected recently by invoking an overturned stratigraphic sequence. A careful review of the data, however, found no evidence that this sequence has been overturned. In addition, many of the assumptions, on which the conjecture of the fossil beds being postMiddle Jurassic is imprudently based, are self-contradictory or otherwise misleading. Thus, the postMiddle Jurassic age of the Daohugou beds as an unfounded conclusion can readily be dismissed.

  15. (25143) Itokawa: The Power of Radiometric Techniques for the Interpretation of Remote Thermal Observations in the Light of the Hayabusa Rendezvous Results

    CERN Document Server

    Müller, T G; Usui, F

    2014-01-01

    The near-Earth asteroid (25143) Itokawa was characterised in great detail by the Japanese Hayabusa mission. We revisited the available thermal observations in the light of the true asteroid properties with the goal to evaluate the possibilities and limitations of thermal model techniques. In total, we used 25 published ground-based mid-infrared photometric observations and 5 so far unpublished measurements from the Japanese infrared astronomical satellite AKARI in combination with improved H-G values. Our thermophysical model (TPM) approach allowed us to determine correctly the sense of rotation, to estimate the thermal inertia and to derive robust effective size and albedo values by only using a simple spherical shape model. A more complex shape model, derived from light-curve inversion techniques, improved the quality of the predictions considerably and made the interpretation of thermal light-curve possible. The radiometrically derived effective diameter value agrees within 2% of the true Itokawa size valu...

  16. Using the Sonoran Desert test site to monitor the long-term radiometric stability of the Landsat TM/ETM+ and Terra MODIS sensors

    Science.gov (United States)

    Angal, A.; Xiong, X.; Choi, T.; Chander, G.; Wu, A.

    2009-01-01

    Pseudo-invariant ground targets have been extensively used to monitor the long-term radiometric calibration stability of remote sensing instruments. The NASA MODIS Characterization Support Team (MCST), in collaboration with members from the U.S. Geological Survey (USGS) Earth Resources Observation and Science (EROS) Center, has previously demonstrated the use of pseudo-invariant ground sites for the long-term stability monitoring of Terra MODIS and Landsat 7 ETM+ sensors. This paper focuses on the results derived from observations made over the Sonoran Desert. Additionally, Landsat 5 TM data over the Sonoran Desert site were used to evaluate the temporal stability of this site. Top-ofatmosphere (TOA) reflectances were computed for the closely matched TM, ETM+, and MODIS spectral bands over selected regions of interest. The impacts due to different viewing geometries, or the effect of test site Bi-directional Reflectance Distribution Function (BRDF), are also presented. ?? 2009 SPIE.

  17. Remotely controllable liquid marbles

    KAUST Repository

    Zhang, Lianbin

    2012-07-26

    Liquid droplets encapsulated by self-organized hydrophobic particles at the liquid/air interface - liquid marbles - are prepared by encapsulating water droplets with novel core/shell-structured responsive magnetic particles, consisting of a responsive block copolymer-grafted mesoporous silica shell and magnetite core (see figure; P2VP-b-PDMS: poly(2-vinylpyridine-b- dimethylsiloxane)). Desirable properties of the liquid marbles include that they rupture upon ultraviolet illumination and can be remotely manipulated by an external magnetic field. 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Liquid hydrogen in Japan

    Energy Technology Data Exchange (ETDEWEB)

    Yasumi, S. [Iwatani Corp., Osaka (Japan). Dept. of Overseas Business Development

    2009-07-01

    Japan's Iwatani Corporation has focused its attention on hydrogen as the ultimate energy source in future. Unlike the United States, hydrogen use and delivery in liquid form is extremely limited in the European Union and in Japan. Iwatani Corporation broke through industry stereotypes by creating and building Hydro Edge Co. Ltd., Japan's largest liquid hydrogen plant. It was established in 2006 as a joint venture between Iwatani and Kansai Electric Power Group in Osaka. Hydro Edge is Japan's first combined liquid hydrogen and ASU plant, and is fully operational. Liquid oxygen, liquid nitrogen and liquid argon are separated from air using the cryogenic energy of liquefied natural gas fuel that is used for power generation. Liquid hydrogen is produced efficiently and simultaneously using liquid nitrogen. Approximately 12 times as much hydrogen in liquid form can be transported and supplied as pressurized hydrogen gas. This technology is a significant step forward in the dissemination and expansion of hydrogen in a hydrogen-based economy.

  19. 无人机航放测量新技术的示范应用%The applied demonstration of new drone aero-radiometric technique

    Institute of Scientific and Technical Information of China (English)

    高国林; 邱崇涛; 王景丹; 沈正新; 李江坤

    2016-01-01

    基于我国首套无人机平台的航放测量系统,简要介绍了无人机航放探测原理及校准、测量、数据处理等技术;通过在新疆克拉玛依和喀什等地区开展的应用示范工作,获取了内容丰富的无人机航放测量结果;结合地质、遥感资料以及岩石放射性参数、航放异常检查结果,对区域航放特征和局部航放异常进行综合分析评价,说明了该技术在基础地质调查、放射性矿产勘查和非放射性矿产调查中的有效性;最后对比有人机和无人机的航放测量效果并进行了简单评价.%Based on the first airborne gamma ray spectrometer on the drone in China,this paper briefly described related techniques such as principle,calibration, measurement,and data processing.Through the demonstration surveys in both Karamay and Kashi,rich re-sults of aero radiometric survey were obtained.Combined with regional geology,remote sensing data,radioactivity characteristics of rocks and the results of ground-checking,the authors analyzed and evaluated the regional features and the local anomalies of aero-radiometric survey comprehensively.The results show that the technique is an effective method in such aspects as basic geological investigation and exploration of radioactive and non-radioactive mineral resource.Finally,the measurement technique was evaluated briefly for the drone based on the fix-wing craft.

  20. Volcanic Event Recurrence Rate Model (VERRM): Incorporating Radiometric Ages, Volcanic Stratigraphy and Paleomagnetic Data into a Monte Carlo Simulation to Estimate Uncertainty in Recurrence Rate through Time

    Science.gov (United States)

    Wilson, J. A.; Richardson, J. A.

    2015-12-01

    Traditional methods used to calculate recurrence rate of volcanism, such as linear regression, maximum likelihood and Weibull-Poisson distributions, are effective at estimating recurrence rate and confidence level, but these methods are unable to estimate uncertainty in recurrence rate through time. We propose a new model for estimating recurrence rate and uncertainty, Volcanic Event Recurrence Rate Model. VERRM is an algorithm that incorporates radiometric ages, volcanic stratigraphy and paleomagnetic data into a Monte Carlo simulation, generating acceptable ages for each event. Each model run is used to calculate recurrence rate using a moving average window. These rates are binned into discrete time intervals and plotted using the 5th, 50th and 95th percentiles. We present recurrence rates from Cima Volcanic Field (CA), Yucca Mountain (NV) and Arsia Mons (Mars). Results from Cima Volcanic Field illustrate how several K-Ar ages with large uncertainties obscure three well documented volcanic episodes. Yucca Mountain results are similar to published rates and illustrate the use of using the same radiometric age for multiple events in a spatially defined cluster. Arsia Mons results show a clear waxing/waning of volcanism through time. VERRM output may be used for a spatio-temporal model or to plot uncertainty in quantifiable parameters such as eruption volume or geochemistry. Alternatively, the algorithm may be reworked to constrain geomagnetic chrons. VERRM is implemented in Python 2.7 and takes advantage of NumPy, SciPy and matplotlib libraries for optimization and quality plotting presentation. A typical Monte Carlo simulation of 40 volcanic events takes a few minutes to couple hours to complete, depending on the bin size used to assign ages.

  1. The Liquid Vapour Interface

    DEFF Research Database (Denmark)

    Als-Nielsen, Jens Aage

    1985-01-01

    In this short review we are concerned with the density variation across the liquid-vapour interface, i.e. from the bulk density of the liquid to the essentially zero density of the vapour phase. This density variation can in principle be determined from the deviation of the reflectivity from...

  2. LIGHT NONAQUEOUS PHASE LIQUIDS

    Science.gov (United States)

    Nonaqueous phase liquids (NAPLS) are hydrocarbons that exist as a separate, immiscible phase when in contact with water and/or air. ifferences in the physical and chemical properties of water and NAPL result in the formation of a physical interface between the liquids which preve...

  3. Disposal of Liquid Propellants

    Science.gov (United States)

    1990-03-13

    SYNTHESIS OF LIQUID PROPELLANT Hydroxylammonium nitrate (HAN), prepared via the electrolysis of nitric acid, is commercially available as a high-purity...stack gases, and brine solution from the wet scrubber (82). 5 Applicability/Limitation Most types of solid, liquid, and gaseous organic wastes or

  4. Liquid crystal colloids

    Directory of Open Access Journals (Sweden)

    2010-01-01

    Full Text Available This special issue of "Condensed Matter Physics" focuses on the most recent developments in the study of a fascinating soft matter system, representing colloidal particles in a liquid crystalline environment. Furthermore, some articles address pioneering steps in the discovery of liquid crystals going back to 1861 paper by Julius Planer.

  5. INEEL Liquid Effluent Inventory

    Energy Technology Data Exchange (ETDEWEB)

    Major, C.A.

    1997-06-01

    The INEEL contractors and their associated facilities are required to identify all liquid effluent discharges that may impact the environment at the INEEL. This liquid effluent information is then placed in the Liquid Effluent Inventory (LEI) database, which is maintained by the INEEL prime contractor. The purpose of the LEI is to identify and maintain a current listing of all liquid effluent discharge points and to identify which discharges are subject to federal, state, or local permitting or reporting requirements and DOE order requirements. Initial characterization, which represents most of the INEEL liquid effluents, has been performed, and additional characterization may be required in the future to meet regulations. LEI information is made available to persons responsible for or concerned with INEEL compliance with liquid effluent permitting or reporting requirements, such as the National Pollutant Discharge Elimination System, Wastewater Land Application, Storm Water Pollution Prevention, Spill Prevention Control and Countermeasures, and Industrial Wastewater Pretreatment. The State of Idaho Environmental Oversight and Monitoring Program also needs the information for tracking liquid effluent discharges at the INEEL. The information provides a baseline from which future liquid discharges can be identified, characterized, and regulated, if appropriate. The review covered new and removed buildings/structures, buildings/structures which most likely had new, relocated, or removed LEI discharge points, and at least 10% of the remaining discharge points.

  6. The TIPS Liquidity Premium

    DEFF Research Database (Denmark)

    Andreasen, Martin Møller; Christensen, Jens H.E.; Simon Riddell, Simon

    We introduce an arbitrage-free term structure model of nominal and real yields that accounts for liquidity risk in Treasury inflation-protected securities (TIPS). The novel feature of our model is to identify liquidity risk from individual TIPS prices by accounting for the tendency that TIPS, lik...

  7. Air/liquid collectors

    DEFF Research Database (Denmark)

    Jensen, Søren Østergaard; Olesen, Ole; Kristiansen, Finn Harken

    1997-01-01

    This report determine efficiency equations for combined air/liquid solar collectors by measurements on to different air/liquid collectors. Equations which contain all relevant informations on the solar collectors. A simulation program (Kviksol) has been modified in order to be able to handle...

  8. Liquid heat capacity lasers

    Science.gov (United States)

    Comaskey, Brian J.; Scheibner, Karl F.; Ault, Earl R.

    2007-05-01

    The heat capacity laser concept is extended to systems in which the heat capacity lasing media is a liquid. The laser active liquid is circulated from a reservoir (where the bulk of the media and hence waste heat resides) through a channel so configured for both optical pumping of the media for gain and for light amplification from the resulting gain.

  9. Liquid Chromatography in 1982.

    Science.gov (United States)

    Freeman, David H.

    1982-01-01

    Reviews trends in liquid chromatography including apparatus, factors affecting efficient separation of a mixture (peak sharpness and speed), simplified problem-solving, adsorption, bonded phase chromatography, ion selectivity, and size exclusion. The current trend is to control chemical selectivity by the liquid phase. (Author/JN)

  10. Column Liquid Chromatography.

    Science.gov (United States)

    Majors, Ronald E.; And Others

    1984-01-01

    Reviews literature covering developments of column liquid chromatography during 1982-83. Areas considered include: books and reviews; general theory; columns; instrumentation; detectors; automation and data handling; multidimensional chromatographic and column switching techniques; liquid-solid chromatography; normal bonded-phase, reversed-phase,…

  11. Modeling of ionic liquids

    Science.gov (United States)

    Tatlipinar, Hasan

    2017-02-01

    Ionic liquids are very important entry to industry and technology. Because of their unique properties they may classified as a new class of materials. IL usually classified as a high temperature ionic liquids (HTIL) and room temperature ionic liquids (RTIL). HTIL are molten salts. There are many research studies on molten salts such as recycling, new energy sources, rare elements mining. RTIL recently become very important in daily life industry because of their "green chemistry" properties. As a simple view ionic liquids consist of one positively charged and one negatively charged components. Because of their Coulombic or dispersive interactions the local structure of ionic liquids emerges. In this presentation the local structural properties of the HTIL are discussed via correlation functions and integral equation theories. RTIL are much more difficult to do modeling, but still general consideration for the modeling of the HTIL is valid also for the RTIL.

  12. Modern methods for vancomycin determination in biological fluids by methods based on high-performance liquid chromatography--A review.

    Science.gov (United States)

    Javorska, Lenka; Krcmova, Lenka Kujovska; Solichova, Dagmar; Solich, Petr; Kaska, Milan

    2016-01-01

    Vancomycin is a glycopeptide antibiotic used in the therapy of severe bacterial infection. The monitoring of vancomycin levels is recommended because of its narrow therapeutic index and toxicity. This measurement is especially appropriate in patients with unstable renal functions, who receive high doses of vancomycin or present serious bacterial infections accompanied by important sequestration of liquids when it could be difficult to achieve the optimal therapeutic dose. Most of the methods for vancomycin determination in routine practice are immunoassays. However, chromatography-based techniques in combination with UV or mass spectrometry detection provide results with greater accuracy and precision also in complicated biological matrices. This review provides a detailed overview of modern approaches for the chromatographic separation of vancomycin in various biological samples and useful sample preparation procedures for vancomycin determination in various biological fluids.

  13. Liquid-liquid phase transition in Stillinger-Weber silicon

    Energy Technology Data Exchange (ETDEWEB)

    Beaucage, Philippe; Mousseau, Normand [Departement de Physique and Regroupement Quebecois sur les Materiaux de Pointe, Universite de Montreal, CP 6128, Succursale Centre-ville, Montreal, QC, H3C 3J7 (Canada)

    2005-04-20

    It was recently demonstrated that Stillinger-Weber silicon undergoes a liquid-liquid first-order phase transition deep into the supercooled region (Sastry and Angell 2003 Nat. Mater. 2 739). Here we study the effects of perturbations on this phase transition. We show that the order of the liquid-liquid transition changes with negative pressure. We also find that the liquid-liquid transition disappears when the three-body term of the potential is strengthened by as little as 5%. This implies that the details of the potential could affect strongly the nature and even the existence of the liquid-liquid phase.

  14. The Risk Components of Liquidity

    OpenAIRE

    Chollete, Lorán; Næs, Randi; Johannes A. Skjeltorp

    2008-01-01

    Does liquidity risk differ depending on our choice of liquidity proxy? Unlike literature that considers common liquidity variation, we focus on identifying different components of liquidity, statistically and economically, using more than a decade of US transaction data. We identify three main statistical liquidity factors which are utilized in a linear asset pricing framework. We motivate a correspondence of the statistical factors to traditional dimensions of liquidity as well as the notion...

  15. Liquid metal enabled microfluidics.

    Science.gov (United States)

    Khoshmanesh, Khashayar; Tang, Shi-Yang; Zhu, Jiu Yang; Schaefer, Samira; Mitchell, Arnan; Kalantar-Zadeh, Kourosh; Dickey, Michael D

    2017-03-14

    Several gallium-based liquid metal alloys are liquid at room temperature. As 'liquid', such alloys have a low viscosity and a high surface tension while as 'metal', they have high thermal and electrical conductivities, similar to mercury. However, unlike mercury, these liquid metal alloys have low toxicity and a negligible vapor pressure, rendering them much safer. In comparison to mercury, the distinguishing feature of these alloys is the rapid formation of a self-limiting atomically thin layer of gallium oxide over their surface when exposed to oxygen. This oxide layer changes many physical and chemical properties of gallium alloys, including their interfacial and rheological properties, which can be employed and modulated for various applications in microfluidics. Injecting liquid metal into microfluidic structures has been extensively used to pattern and encapsulate highly deformable and reconfigurable electronic devices including electrodes, sensors, antennas, and interconnects. Likewise, the unique features of liquid metals have been employed for fabricating miniaturized microfluidic components including pumps, valves, heaters, and electrodes. In this review, we discuss liquid metal enabled microfluidic components, and highlight their desirable attributes including simple fabrication, facile integration, stretchability, reconfigurability, and low power consumption, with promising applications for highly integrated microfluidic systems.

  16. Spreading of miscible liquids

    Science.gov (United States)

    Walls, Daniel J.; Haward, Simon J.; Shen, Amy Q.; Fuller, Gerald G.

    2016-05-01

    Miscible liquids commonly contact one another in natural and technological situations, often in the proximity of a solid substrate. In the scenario where a drop of one liquid finds itself on a solid surface and immersed within a second, miscible liquid, it will spread spontaneously across the surface. We show experimental findings of the spreading of sessile drops in miscible environments that have distinctly different shape evolution and power-law dynamics from sessile drops that spread in immiscible environments, which have been reported previously. We develop a characteristic time to scale radial data of the spreading sessile drops based on a drainage flow due to gravity. This time scale is effective for a homologous subset of the liquids studied. However, it has limitations when applied to significantly chemically different, yet miscible, liquid pairings; we postulate that the surface energies between each liquid and the solid surface becomes important for this other subset of the liquids studied. Initial experiments performed with pendant drops in miscible environments support the drainage flow observed in the sessile drop systems.

  17. Liquid crystals fundamentals

    CERN Document Server

    Singh, Shri

    2001-01-01

    Liquid crystals are partially ordered systems without a rigid, long-range structure. The study of these materials covers a wide area: chemical structure, physical properties and technical applications. Due to their dual nature - anisotropic physical properties of solids and rheological behavior of liquids - and easy response to externally applied electric, magnetic, optical and surface fields liquid crystals are of greatest potential for scientific and technological applications. The subject has come of age and has achieved the status of being a very exciting interdisciplinary field of scienti

  18. Ionic and Molecular Liquids

    DEFF Research Database (Denmark)

    Chaban, Vitaly V.; Prezhdo, Oleg

    2013-01-01

    Because of their outstanding versatility, room-temperature ionic liquids (RTILs) are utilized in an ever increasing number of novel and fascinating applications, making them the Holy Grail of modern materials science. In this Perspective, we address the fundamental research and prospective...... applications of RTILs in combination with molecular liquids, concentrating on three significant areas: (1) the use of molecular liquids to decrease the viscosity of RTILs; (2) the role of RTIL micelle formation in water and organic solvents; and (3) the ability of RTILs to adsorb pollutant gases. Current...

  19. Liquidity and Risk Management

    OpenAIRE

    Holmström, Bengt; Tirole, Jean

    2007-01-01

    This paper provides a model of the interaction between risk-management practices and market liquidity. On one hand, tighter risk management reduces the maximum position an institution can take, thus the amount of liquidity it can offer to the market. On the other hand, risk managers can take into account that lower liquidity amplifies the effective risk of a position by lengthening the time it takes to sell it. The main result of the paper is that a feedback effect can arise: tighter risk man...

  20. Transient Grating Investigations at Liquid-Liquid Interfaces

    OpenAIRE

    Punzi, Angela; Brodard, Pierre; Vauthey, Eric

    2005-01-01

    A new four-wave-mixing technique with evanescent optical fields generated by total internal reflection at a liquid-liquid interface is described. Several applications of this method to measure thermoacoustic and dynamic properties near liquid-liquid interfaces are presented.

  1. Chiral separation by enantioselective liquid-liquid extraction

    NARCIS (Netherlands)

    Schuur, B.; Verkuijl, B. J. V.; Minnaard, A. J.; De Vries, J. G.; Heeres, H. J.; Feringa, B. L.

    2011-01-01

    The literature on enantioselective liquid-liquid extraction (ELLE) spans more than half a century of research. Nonetheless, a comprehensive overview has not appeared during the past few decades. Enantioselective liquid-liquid extraction is a technology of interest for a wide range of chemists and ch

  2. Liquid-Liquid Hydrocyclone Adopted in Jilin Oil Fields

    Institute of Scientific and Technical Information of China (English)

    1996-01-01

    @@ As a new invention with high technique, liquid-liquid hydrocyclone (LLH) was developed in the world in the 1980s. It is designed to separate mutually insoluble liquid mixtures by its geometry and structure which cause an eddy motion in the internal of the liquid. It is characterized by the absence of moving parts in itself.

  3. Beyond dispersive liquid-liquid microextraction.

    Science.gov (United States)

    Leong, Mei-I; Fuh, Ming-Ren; Huang, Shang-Da

    2014-03-28

    Dispersive liquid-liquid microextraction (DLLME) and other dispersion liquid-phase microextraction (LPME) methods have been developed since the first DLLME method was reported in 2006. DLLME is simple, rapid, and affords high enrichment factor, this is due to the large contact surface area of the extraction solvent. DLLME is a method suitable for the extraction in many different water samples, but it requires using chlorinated solvents. In recent years, interest in DLLME or dispersion LPME has been focused on the use of low-toxicity solvents and more conveniently practical procedures. This review examines some of the most interesting developments in the past few years. In the first section, DLLME methods are separated in two categories: DLLME with low-density extraction solvent and DLLME with high-density extraction solvent. Besides these methods, many novel special devices for collecting low-density extraction solvent are also mentioned. In addition, various dispersion techniques with LPME, including manual shaking, air-assisted LPME (aspirating and injecting the extraction mixture by syringe), ultrasound-assisted emulsification, vortex-assisted emulsification, surfactant-assisted emulsification, and microwave-assisted emulsification are described. Besides the above methods, combinations of DLLME with other extraction techniques (solid-phase extraction, stir bar sorptive extraction, molecularly imprinted matrix solid-phase dispersion and supercritical fluid extraction) are introduced. The combination of nanotechnique with DLLME is also introduced. Furthermore, this review illustrates the application of DLLME or dispersion LPME methods to separate and preconcentrate various organic analytes, inorganic analytes, and samples.

  4. Fermi liquid theory

    CERN Document Server

    Apostol, M

    2001-01-01

    sup 3 He liquefies at 3.2 K under normal pressure, where its mean inter-particle separation of a few angstroms, is comparable with the range of the interaction potential (and with the mean inter-particle separation in the corresponding ideal gas); its thermal wavelength is about 8 A, so that, under this conditions, sup 3 He is a quantum liquid of fermions, or a Fermi liquid (sometimes called a normal Fermi liquid too). The motion of the sup 3 He atoms in the (repulsive) self-consistent, meanfield potential is affected by inertial effects, i.e. the particles possess an effective mass, and consequently they obey the Fermi distribution, like an ideal Fermi gas. In this paper the Landau's theory of the Fermi liquid is reviewed. (author)

  5. Corporate governance and liquidity

    DEFF Research Database (Denmark)

    Farooq, Omar; Derrabi, Mohamed; Naciri, Monir

    2012-01-01

    This paper examines the impact of corporate governance mechanisms on liquidity in the MENA region, i.e. Morocco, Egypt, Saudi Arabia, United Arab Emirates, Jordan, Kuwait, and Bahrain. Using turnover as a proxy for liquidity, we document significant difference in liquidity between the pre......- and the post-crisis periods in the MENA region. In addition, our results show that bulk of this reduction in turnover can be explained due to weaknesses of corporate governance mechanisms. For example, that dividend payout ratio and choice of auditors – proxies for agency problems – can explain the entire...... difference in liquidity between the two periods. Furthermore, our results indicate that more than 50% of this difference between the two periods can be explained by operational and informational complexity of a firm – proxy for transparency. We argue that poor corporate governance mechanisms increase...

  6. Liquid-Cooled Garment

    Science.gov (United States)

    1977-01-01

    A liquid-cooled bra, offshoot of Apollo moon suit technology, aids the cancer-detection technique known as infrared thermography. Water flowing through tubes in the bra cools the skin surface to improve resolution of thermograph image.

  7. Wettability by Ionic Liquids.

    Science.gov (United States)

    Liu, Hongliang; Jiang, Lei

    2016-01-06

    Ionic liquids (ILs) have become particularly attractive recently because they have demonstrated themselves to be important construction units in the broad fields of chemistry and materials science, from catalysis and synthesis to analysis and electrochemistry, from functional fluids to clean energy, from nanotechnology to functional materials. One of the greatest issues that determines the performance of ILs is the wettability of correlated surfaces. In this concept article, the key developments and issues in IL wettability are surveyed, including the electrowetting of ILs in gas-liquid-solid systems and liquid-liquid-solid systems, ILs as useful probe fluids, the superwettability of Ils, and future directions in IL wettability. This should generate extensive interest in the field and encourage more scientists to engage in this area to tackle its scientific challenges.

  8. Liquid rocket engine injectors

    Science.gov (United States)

    Gill, G. S.; Nurick, W. H.

    1976-01-01

    The injector in a liquid rocket engine atomizes and mixes the fuel with the oxidizer to produce efficient and stable combustion that will provide the required thrust without endangering hardware durability. Injectors usually take the form of a perforated disk at the head of the rocket engine combustion chamber, and have varied from a few inches to more than a yard in diameter. This monograph treats specifically bipropellant injectors, emphasis being placed on the liquid/liquid and liquid/gas injectors that have been developed for and used in flight-proven engines. The information provided has limited application to monopropellant injectors and gas/gas propellant systems. Critical problems that may arise during injector development and the approaches that lead to successful design are discussed.

  9. Lacerations - liquid bandage

    Science.gov (United States)

    ... be found at your local pharmacy. Applying and Caring for a Liquid Bandage With clean hands or ... Bethesda, MD 20894 U.S. Department of Health and Human Services National Institutes of Health Page last updated: ...

  10. Ionic liquids in tribology.

    Science.gov (United States)

    Minami, Ichiro

    2009-06-24

    Current research on room-temperature ionic liquids as lubricants is described. Ionic liquids possess excellent properties such as non-volatility, non-flammability, and thermo-oxidative stability. The potential use of ionic liquids as lubricants was first proposed in 2001 and approximately 70 articles pertaining to fundamental research on ionic liquids have been published through May 2009. A large majority of the cations examined in this area are derived from 1,3-dialkylimidazolium, with a higher alkyl group on the imidazolium cation being beneficial for good lubrication, while it reduces the thermo-oxidative stability. Hydrophobic anions provide both good lubricity and significant thermo-oxidative stability. The anions decompose through a tribochemical reaction to generate metal fluoride on the rubbed surface. Additive technology to improve lubricity is also explained. An introduction to tribology as an interdisciplinary field of lubrication is also provided.

  11. Ionic Liquids in Tribology

    Directory of Open Access Journals (Sweden)

    Ichiro Minami

    2009-06-01

    Full Text Available Current research on room-temperature ionic liquids as lubricants is described. Ionic liquids possess excellent properties such as non-volatility, non-flammability, and thermo-oxidative stability. The potential use of ionic liquids as lubricants was first proposed in 2001 and approximately 70 articles pertaining to fundamental research on ionic liquids have been published through May 2009. A large majority of the cations examined in this area are derived from 1,3-dialkylimidazolium, with a higher alkyl group on the imidazolium cation being beneficial for good lubrication, while it reduces the thermo-oxidative stability. Hydrophobic anions provide both good lubricity and significant thermo-oxidative stability. The anions decompose through a tribochemical reaction to generate metal fluoride on the rubbed surface. Additive technology to improve lubricity is also explained. An introduction to tribology as an interdisciplinary field of lubrication is also provided.

  12. Corporate governance and liquidity

    DEFF Research Database (Denmark)

    Farooq, Omar; Derrabi, Mohamed; Naciri, Monir

    2012-01-01

    This paper examines the impact of corporate governance mechanisms on liquidity in the MENA region, i.e. Morocco, Egypt, Saudi Arabia, United Arab Emirates, Jordan, Kuwait, and Bahrain. Using turnover as a proxy for liquidity, we document significant difference in liquidity between the pre......- and the post-crisis periods in the MENA region. In addition, our results show that bulk of this reduction in turnover can be explained due to weaknesses of corporate governance mechanisms. For example, that dividend payout ratio and choice of auditors – proxies for agency problems – can explain the entire...... difference in liquidity between the two periods. Furthermore, our results indicate that more than 50% of this difference between the two periods can be explained by operational and informational complexity of a firm – proxy for transparency. We argue that poor corporate governance mechanisms increase...

  13. Gases, liquids and solids

    CERN Document Server

    Tabor, David

    1969-01-01

    It has been tradional to treat gases, liquids and solids as if they were completely unrelated material. However, this book shows that many of their bulk properties can been explained in terms of intermolecular forces.

  14. A Radiometric Varying Robust Stereo Matching Algorithm%一种光照度不一致鲁棒立体匹配算法

    Institute of Scientific and Technical Information of China (English)

    曹晓倩; 马彩文

    2014-01-01

    In order to improve the matching rate of radiometric varying stereo images, a novel stereo matching algorithm based on the improved epipolar distance transformation in log-chromaticity space is proposed. In log-chromaticity space, the intensity proportion of stereo image pairs is computed firstly according to raw disparity map;secondly, epipolar distance transformation is performed on left and right images respectively using proportional intensity deviation parameters;at last, the final disparity map is acquired by the belief propagation method. Theoretically, the matching rate of the proposed algorithm is independent of radiometric varying situations including differences in light source’s position, spectrum, intensity and the parameters setting of cameras. Experimental results indicate that the matching rate of the proposed algorithm is improved at most 60%comparing with the original epipolar distance transformation algorithm and at most 78%comparing with the state of art algorithms such as ANCC (adaptive normalized cross correlation) when applied to textureless image pairs.%为了提高光照度不一致立体图像对的匹配率,提出一种基于对数颜色空间下改进极线距离变换的立体匹配算法。在对数颜色空间下,首先根据初始视差图计算立体图像对的灰度比;然后,采用与灰度比成比例的灰度误差系数,分别对左右图像进行极线距离变换;最后利用置信度传播算法计算视差图。理论上,本文算法的匹配结果不会受光源位置、光源谱分布、光照强度以及摄像机参数设置等光照度不一致因素的影响。实验表明:本文算法的匹配率相对于原始极线距离变换算法最多可提高60%;而应用于弱纹理图像对时,相对于当前先进的自适应归一化算法,匹配率最多可提高78%。

  15. Effects of Landsat 5 Thematic Mapper and Landsat 7 Enhanced Thematic Mapper plus radiometric and geometric calibrations and corrections on landscape characterization

    Science.gov (United States)

    Vogelmann, James E.; Helder, Dennis; Morfitt, Ron; Choate, Michael J.; Merchant, James W.; Bulley, Henry

    2001-01-01

    The Thematic Mapper (TM) instruments onboard Landsats 4 and 5 provide high-quality imagery appropriate for many different applications, including land cover mapping, landscape ecology, and change detection. Precise calibration was considered to be critical to the success of the Landsat 7 mission and, thus, issues of calibration were given high priority during the development of the Enhanced Thematic Mapper Plus (ETM+). Data sets from the Landsat 5 TM are not routinely corrected for a number of radiometric and geometric artifacts, including memory effect, gain/bias, and interfocal plane misalignment. In the current investigation, the effects of correcting vs. not correcting these factors were investigated for several applications. Gain/bias calibrations were found to have a greater impact on most applications than did memory effect calibrations. Correcting interfocal plane offsets was found to have a moderate effect on applications. On June 2, 1999, Landsats 5 and 7 data were acquired nearly simultaneously over a study site in the Niobrara, NE area. Field radiometer data acquired at that site were used to facilitate crosscalibrations of Landsats 5 and 7 data. Current findings and results from previous investigations indicate that the internal calibrator of Landsat 5 TM tracked instrument gain well until 1988. After this, the internal calibrator diverged from the data derived from vicarious calibrations. Results from this study also indicate very good agreement between prelaunch measurements and vicarious calibration data for all Landsat 7 reflective bands except Band 4. Values are within about 3.5% of each other, except for Band 4, which differs by 10%. Coefficient of variation (CV) values derived from selected targets in the imagery were also analyzed. The Niobrara Landsat 7 imagery was found to have lower CV values than Landsat 5 data, implying that lower levels of noise characterize Landsat 7 data than current Landsat 5 data. It was also found that following

  16. Liquid Crystal Airborne Display

    Science.gov (United States)

    1977-08-01

    81/2X 11- 10 -9 .8 display using a large advertising alphanimeric ( TCI ) has been added to the front of the optical box used in the F-4 aircraft for HUD...properties over a wide range of tempera - tures, including normal room temperature. What are Liquid Crystals? Liquid crystals have been classified in three...natic fanctions and to present data needed for the semi- automatic and manual control of system functions. Existing aircraft using CRT display

  17. COMMERCIAL BANK LIQUIDITY MANAGEMENT

    OpenAIRE

    KOREKOV A.V.

    2015-01-01

    Bank liquidity management and optimal resource allocation of commercial bank Nostro accounts balances receive much less attention from the scientists compared to the questions on capital structure, funding, credit risk analysis and stress testing. Optimal liquidity management is a way to lower bank costs and risks, which are going to increase over time, especially when money markets are dry of free funds. There are two sides of the issue to be analyzed. The optimal resource allocation and cor...

  18. Gas to liquids

    Energy Technology Data Exchange (ETDEWEB)

    Roche, Pat

    2011-04-15

    Sasol, a South African company, along with the Canadian company Talisman, are looking at gas to liquid process opportunities in North America. Sasol decided to launch a study into the feasibility of gas to liquid (GTL) operation in western Canada, and according to previous studies GTL would need a crude barrel price of $85 or higher combined with a gas price of $4 or less to be economical. Sasol is already operating a GTL plant in Qatar.

  19. Quantification of achiral and chiral methylsulfonyl polychlorinated biphenyl metabolites by column-switching liquid chromatography-atmospheric pressure photoionization-tandem mass spectrometry.

    Science.gov (United States)

    Cooper, Victoria I; Letcher, Robert J; Dietz, Rune; Sonne, Christian; Wong, Charles S

    2012-12-14

    An enantioselective heart-cut column-switching liquid chromatography-atmospheric pressure photoionization-tandem mass spectrometry method was developed for the analysis of 25 methylsulfonyl polychlorinated biphenyl metabolites in tissue extracts. Use of a pyrenyl-ethyl silica column in the first dimension enabled separation of all but two pairs of isobaric analytes. Enantioseparation was achieved for 9 out of the 10 atropisomeric analytes using a Chiralpak AD-H amylose-based column within 93 min, resulting in greater chromatographic resolution of enantioseparation over shorter analysis time by up to a factor of three, compared to previous one-dimensional and multi-dimensional gas chromatography-based methods. Precision for concentration and enantiomer fraction measurements was within 11% and 3% relative standard deviation, respectively. Limits of detection ranged from 0.01 to 1.73 ng on-column. Meta-congeners had poorer sensitivity (i.e., ng on-column), consistent with existing gas chromatography-based methods. Despite this limitation, the method was successfully applied to the analysis of Greenland sledge dog adipose tissue extracts, which had highly non-racemic residues of 4-methylsulfonyl-2,2',3,5',6-pentachlorobiphenyl and 4'-methylsulfonyl-2,2',3,3',4,6'-hexachlorobiphenyl, consistent with past reports in Arctic mammals.

  20. The reversibility and first-order nature of liquid-liquid transition in a molecular liquid

    Science.gov (United States)

    Kobayashi, Mika; Tanaka, Hajime

    2016-11-01

    Liquid-liquid transition is an intriguing phenomenon in which a liquid transforms into another liquid via the first-order transition. For molecular liquids, however, it always takes place in a supercooled liquid state metastable against crystallization, which has led to a number of serious debates concerning its origin: liquid-liquid transition versus unusual nano-crystal formation. Thus, there have so far been no single example free from such debates, to the best of our knowledge. Here we show experimental evidence that the transition is truly liquid-liquid transition and not nano-crystallization for a molecular liquid, triphenyl phosphite. We kinetically isolate the reverse liquid-liquid transition from glass transition and crystallization with a high heating rate of flash differential scanning calorimetry, and prove the reversibility and first-order nature of liquid-liquid transition. Our finding not only deepens our physical understanding of liquid-liquid transition but may also initiate a phase of its research from both fundamental and applications viewpoints.

  1. Nuclear geochronology. Chapter 6: Sedimentary rocks dating by the Rubidium-Strontium (Rb/Sr) and Potassium-Argon (K/Ar) radiometric methods; Geocronologia nuclear. Capitulo 6: Datacao de rochas sedimentares pelos metodos radiometricos rubidio-estroncio (Rb/Sr) e potassio-argonio (K/Ar)

    Energy Technology Data Exchange (ETDEWEB)

    Thomaz Filho, Antonio [Universidade do Estado, Rio de Janeiro, RJ (Brazil). Inst. de Geociencias; Mizusaki, Ana Maria Pimentel [Rio Grande do Sul Univ., Porto Alegre, RS (Brazil). Inst. de Geociencias; Kawashita, Koji [Sao Paulo Univ., SP (Brazil). Inst. de Geociencias; Torquato, Joaquim Raul [Ceara Univ., Fortaleza, CE (Brazil). Dept. de Geologia

    1995-12-31

    The paper deals with the Rubidium/Strontium (Rb/Sr) and Potassium/Argon (K/Ar) radiometric methods application in the sedimentary rocks dating, including the methodology, the method restrictions and the ages meaning. The work concludes that the sedimentary rocks radiometric dating, by the Rb/Sr method is possible, furnishing results geologically significant. The {sup 87} Sr/{sup 86} Sr of marine carbonates has propitiated, mainly in the last years, the dating possibility of sedimentary rocks. The K/Ar radiometric method has been applied to determine the diagenetic events age of the sedimentary rocks, including its application in mesozoic and recent rocks, where the RB/Sr radiometric method presents some limitations 71 refs., 18 figs.

  2. A data format 'EUMELDAT: European Material, Energetic and Luminous Data' for luminous and radiometric properties of daylighting systems; EUMELDAT ''Ein europaeisches Datenformat fuer strahlungsphysikalische und lichttechnische Kennzahlen von Tageslichtsystemen

    Energy Technology Data Exchange (ETDEWEB)

    Herrmann, B.; Rosemann, A.; Aydinli, S.; Kaase, H. [Technische Univ. Berlin (Germany). Fachgebiet Lichttechnik

    2003-07-01

    This paper describes a data format (EUMELDAT: European Material, Energetic and Luminous Data) for luminous and radiometric properties of daylighting systems for different light incidences and observer directions. The data format is based on a coordinate system whose properties and advantages are discussed in this paper. The technical description of the data format can be found on the web page of the lighting institute (http://ntife.ee.tu-berlin.de/Lichttechnik/Eumeldat.html). (orig.)

  3. Automated radioanalytical system incorporating microwave-assisted sample preparation, chemical separation, and online radiometric detection for the monitoring of total 99Tc in nuclear waste processing streams.

    Science.gov (United States)

    Egorov, Oleg B; O'Hara, Matthew J; Grate, Jay W

    2012-04-03

    An automated fluidic instrument is described that rapidly determines the total (99)Tc content of aged nuclear waste samples, where the matrix is chemically and radiologically complex and the existing speciation of the (99)Tc is variable. The monitor links microwave-assisted sample preparation with an automated anion exchange column separation and detection using a flow-through solid scintillator detector. The sample preparation steps acidify the sample, decompose organics, and convert all Tc species to the pertechnetate anion. The column-based anion exchange procedure separates the pertechnetate from the complex sample matrix, so that radiometric detection can provide accurate measurement of (99)Tc. We developed a preprogrammed spike addition procedure to automatically determine matrix-matched calibration. The overall measurement efficiency that is determined simultaneously provides a self-diagnostic parameter for the radiochemical separation and overall instrument function. Continuous, automated operation was demonstrated over the course of 54 h, which resulted in the analysis of 215 samples plus 54 hly spike-addition samples, with consistent overall measurement efficiency for the operation of the monitor. A sample can be processed and measured automatically in just 12.5 min with a detection limit of 23.5 Bq/mL of (99)Tc in low activity waste (0.495 mL sample volume), with better than 10% RSD precision at concentrations above the quantification limit. This rapid automated analysis method was developed to support nuclear waste processing operations planned for the Hanford nuclear site.

  4. Radiometric and geometric evaluation of GeoEye-1, WorldView-2 and Pléiades-1A stereo images for 3D information extraction

    Science.gov (United States)

    Poli, D.; Remondino, F.; Angiuli, E.; Agugiaro, G.

    2015-02-01

    Today the use of spaceborne Very High Resolution (VHR) optical sensors for automatic 3D information extraction is increasing in the scientific and civil communities. The 3D Optical Metrology (3DOM) unit of the Bruno Kessler Foundation (FBK) in Trento (Italy) has collected VHR satellite imagery, as well as aerial and terrestrial data over Trento for creating a complete testfield for investigations on image radiometry, geometric accuracy, automatic digital surface model (DSM) generation, 2D/3D feature extraction, city modelling and data fusion. This paper addresses the radiometric and the geometric aspects of the VHR spaceborne imagery included in the Trento testfield and their potential for 3D information extraction. The dataset consist of two stereo-pairs acquired by WorldView-2 and by GeoEye-1 in panchromatic and multispectral mode, and a triplet from Pléiades-1A. For reference and validation, a DSM from airborne LiDAR acquisition is used. The paper gives details on the project, dataset characteristics and achieved results.

  5. Dose of radiometric exposure of granites from state of Rondonia, Brazil; Dose de exposicao radiometrica de granitos do estado de Rondonia, Brasil

    Energy Technology Data Exchange (ETDEWEB)

    Bonotto, Daniel Marcos; Leite Junior, Washington Barbosa, E-mail: danielbonotto@yahoo.com.br, E-mail: wleite@rc.unesp.br [Instituto de Geociencias e Ciencias Exatas (IGCE/UNESP), Rio Claro, SP (Brazil); Payolla, Bruno Leonelo, E-mail: bruno@eln.gov.br [Centrais Eletricas do Norte do Brasil S.A., ELETRONORTE, Brasilia, DF (Brazil); Bettencourt, Jorge da Silva, E-mail: jsbetten@usp.br [Instituto de Geociencias (IG), USP, Sao Paulo, SP (Brazil); Silveira, Ene Gloria da, E-mail: ene_gloria@yahoo.com.br [Fundacao Universidade Federal de Rondonia, UNIR, Porto Velho, RO (Brazil)

    2009-07-15

    This work evaluated the activity concentration of the radioelements K, eU and eTh in samples of granites from Rondonia State, Brazil. The statistical analysis of the data indicated that they fit lognormal distributions. The modal values correspond to about 11% for K, 29 ppm for eU and 85 ppm for eTh. Direct significant correlations were found among the concentrations of the three radioelements, i.e. r = 0.71 (between K and eU), r = 0.72 (between K and eTh), and r = 0.72 (between eU and eTh), suggesting congruency of their accumulation in minerals occurring in the rocks analyzed. The activity concentration data allowed estimate the absorbed dose rate in air at 1 m above the ground, which also fits a lognormal distribution characterized by a mode of 2.7 mSv/y that is slightly higher than the average worldwide exposure of 2.4 mSv/y. The results obtained also allowed evaluate if the granites analyzed are radiometrically suitable as building and ornamental materials. (author)

  6. Radiometric ligand binding assay for C-reactive protein. Complexed C-reactive protein is not detectable in acute phase serum.

    Science.gov (United States)

    De Beer, F C; Shine, B; Pepys, M B

    1982-10-01

    A radiometric ligand binding assay for human C-reactive protein (CRP) was established using pneumococcal C polysaccharide (CPS) coupled to magnetizable cellulose particles as the solid phase ligand. Competition for binding to the solid phase between 125I-CRP and unlabelled CRP permitted detection of 30 micrograms/l of CRP and the precise assay of concentrations up to 3000 micrograms/l. Identical results were obtained when the assay was used to quantitate isolated pure CRP and pure CRP added to normal human serum. However in vitro addition of known ligands for CRP to acute phase serum resulted in lowering of the apparent CRP concentration in this assay and addition of as little as 1 microgram/l of free CPS or 1 mg/l of lecithin was demonstrable in this way. A combination of the ligand binding assay and the standard electroimmunoassay for CRP was therefore used to test acute phase sera for the presence of CRP complexed in vitro. No evidence of complexed CRP was detected among sera containing between 1-319 mg/l of CRP from patients with Hodgkin's disease (10), rheumatoid arthritis (10), Crohn's disease (19) and various microbial infections (11), including six with subacute bacterial endocarditis. Since it is likely that CRP does form complexes with its ligands in the plasma these results suggest that complexed CRP is rapidly cleared from the circulation.

  7. Comparison of Northern Ireland radon maps based on indoor radon measurements and geology with maps derived by predictive modelling of airborne radiometric and ground permeability data.

    Science.gov (United States)

    Appleton, J D; Miles, J C H; Young, M

    2011-03-15

    Publicly available information about radon potential in Northern Ireland is currently based on indoor radon results averaged over 1-km grid squares, an approach that does not take into account the geological origin of the radon. This study describes a spatially more accurate estimate of the radon potential of Northern Ireland using an integrated radon potential mapping method based on indoor radon measurements and geology that was originally developed for mapping radon potential in England and Wales. A refinement of this method was also investigated using linear regression analysis of a selection of relevant airborne and soil geochemical parameters from the Tellus Project. The most significant independent variables were found to be eU, a parameter derived from airborne gamma spectrometry measurements of radon decay products in the top layer of soil and exposed bedrock, and the permeability of the ground. The radon potential map generated from the Tellus data agrees in many respects with the map based on indoor radon data and geology but there are several areas where radon potential predicted from the airborne radiometric and permeability data is substantially lower. This under-prediction could be caused by the radon concentration being lower in the top 30 cm of the soil than at greater depth, because of the loss of radon from the surface rocks and soils to air. Copyright © 2011. Published by Elsevier B.V.

  8. Evaluation of element migration from food plastic packagings into simulated solutions using radiometric method; Avaliacao da migracao de elementos de embalagens plasticas de alimentos para solucoes simulantes pelo metodo radiometrico

    Energy Technology Data Exchange (ETDEWEB)

    Soares, Eufemia Paez [Escola SENAI ' Fundacao Zerrenner' , Sao Paulo, SP (Brazil)]. E-mail: vlcastro@dialdata.com.br; Saiki, Mitiko [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil)]. E-mail: mitiko@ipen.br; Wiebeck, Helio [Sao Paulo Univ., SP (Brazil). Escola Politecnica]. E-mail: hwiebeck@usp.br

    2005-07-01

    In the present study a radiometric method was established to determine the migration of elements from food plastic packagings to a simulated acetic acid solution. This radiometric method consisted of irradiating plastic samples with neutrons at IEA-R1 nuclear reactor for a period of 16 hours under a neutron flux of 10{sup 12} n cm{sup -2} s{sup -1} and, then to expose them to the element migration into a simulated solution. The radioactivity of the activated elements transferred to the solutions was measured to evaluate the migration. The experimental conditions were: time of exposure of 10 days at 40 deg C and 3% acetic acid solution was used as simulated solution, according to the procedure established by the National Agency of Sanitary Monitoring (ANVISA). The migration study was applied for plastic samples from soft drink and juice packagings. The results obtained indicated the migration of elements Co, Cr and Sb. The advantage of this methodology was no need to analyse the blank of simulantes, as well as the use of high purity simulated solutions. Besides, the method allows to evaluate the migration of the elements into the food content instead of simulated solution. The detention limits indicated high sensitivity of the radiometric method. (author)

  9. Supercooled liquids for pedestrians

    Science.gov (United States)

    Cavagna, Andrea

    2009-06-01

    When we lower the temperature of a liquid, at some point we meet a first order phase transition to the crystal. Yet, under certain conditions it is possible to keep the system in its metastable phase and to avoid crystallization. In this way the liquid enters in the supercooled phase. Supercooled liquids have a very rich phenomenology, which is still far from being completely understood. To begin with, there is the problem of how to prevent crystallization and how deeply the liquid can be supercooled before a metastability limit is hit. But by far the most interesting feature of supercooled liquids is the dynamic glass transition: when the temperature is decreased below a certain point, the relaxation time increases so much that a dramatic dynamical arrest intervenes and we are unable to equilibrate the system within reasonable experimental times. The glass transition is a phenomenon whose physical origin has stirred an enormous interest in the last hundred years. Why does it occur? Is it just a conventional reference point, or does it have a more profound physical meaning? Is it a purely dynamical event, or the manifestation of a true thermodynamic transition? What is the correlation length associated to the sharp increase of the relaxation time? Can we define a new kind of amorphous order? A shared theory of supercooled liquids and the glass transition does not yet exist and these questions are still largely open. Here, I will illustrate in the most elementary fashion the main phenomenological traits of supercooled liquids and discuss in a very partial way a few theoretical ideas on the subject.

  10. Liquidity Risk and Syndicate Structure

    OpenAIRE

    Evan Gatev; Philip Strahan

    2008-01-01

    We offer a new explanation of loan syndicate structure based on banks' comparative advantage in managing systematic liquidity risk. When a syndicated loan to a rated borrower has systematic liquidity risk, the fraction of passive participant lenders that are banks is about 8% higher than for loans without liquidity risk. In contrast, liquidity risk does not explain the share of banks as lead lenders. Using a new measure of ex-ante liquidity risk exposure, we find further evidence that syndica...

  11. On the identification of liquid surface properties using liquid bridges.

    Science.gov (United States)

    Kostoglou, M; Karapantsios, T D

    2015-08-01

    The term liquid bridge refers to the specific silhouette of a liquid volume when it is placed between two solid surfaces. Liquid bridges have been studied extensively both theoretically and experimentally during the last century due to their significance in many technological applications. It is worth noticing that even today new technological applications based on liquid bridges continue to appear. A liquid bridge has a well-defined surface configuration dictated by a rigid theoretical foundation so the potential of its utilization as a tool to study surface properties of liquids is apparent. However, it is very scarce in literature that the use of liquid bridges is suggested as an alternative to the well-established drop techniques (pendant/sessile drop). The present work (i) presents the theoretical background for setting up a liquid-bridge based surface property estimation problem, (ii) describes the required experimental equipment and procedures and (iii) performs a thorough literature review on the subject. A case with particular interest is that of liquid bridges made of electrically conducting liquids forming between two conducting solids; such a liquid bridge presents an integral electrical conductance value which is sensitive to the specific silhouette of the bridge. This enables the use of this integral conductance as shape descriptor instead of the conventional image processing techniques. Several attempts in literature for the estimation of liquid surface tension, liquid-solid contact angle and surfactant induced surface elasticity for conducting or non/conducting liquids are presented and the prospects of the technique are discussed.

  12. Redox chemistry at liquid/liquid interfaces

    Science.gov (United States)

    Volkov, A. G.; Deamer, D. W.

    1997-01-01

    The interface between two immiscible liquids with immobilized photosynthetic pigments can serve as the simplest model of a biological membrane convenient for the investigation of photoprocesses accompanied by spatial separation of charges. As it follows from thermodynamics, if the resolvation energies of substrates and products are very different, the interface between two immiscible liquids may act as a catalyst. Theoretical aspects of charge transfer reactions at oil/water interfaces are discussed. Conditions under which the free energy of activation of the interfacial reaction of electron transfer decreases are established. The activation energy of electron transfer depends on the charges of the reactants and dielectric permittivity of the non-aqueous phase. This can be useful when choosing a pair of immiscible solvents to decrease the activation energy of the reaction in question or to inhibit an undesired process. Experimental interfacial catalytic systems are discussed. Amphiphilic molecules such as chlorophyll or porphyrins were studied as catalysts of electron transfer reactions at the oil/water interface.

  13. Laser imaging in liquid-liquid flows

    Science.gov (United States)

    Abidin, M. I. I. Zainal; Park, Kyeong H.; Voulgaropoulos, Victor; Chinaud, Maxime; Angeli, Panagiota

    2016-11-01

    In this work, the flow patterns formed during the horizontal flow of two immiscible liquids are studied. The pipe is made from acrylic, has an ID of 26 mm and a length of 4 m. A silicone oil (5cSt) and a water/glycerol mixture are used as test fluids. This set of liquids is chosen to match the refractive indices of the phases and enable laser based flow pattern identification. A double pulsed Nd:Yag laser was employed (532mm) with the appropriate optics to generate a laser sheet at the middle of the pipe. The aqueous phase was dyed with Rhodamine 6G, to distinguish between the two phases. Experiments were carried out for mixture velocities ranging from 0.15 to 2 m/s. Different inlet designs were used to actuate flow patterns in a controlled way and observe their development downstream the test section. A static mixer produced dispersed flow at the inlet which separated downstream due to enhanced coalescence. On the other hand, the use of a cylindrical bluff body at the inlet created non-linear interfacial waves in initially stratified flows from which drops detached leading to the transition to dispersed patterns. From the detailed images important flow parameters were measured such as wave characteristics and drop size. Project funded under the UK Engineering and Physical Sciences Research Council (EPSRC) Programme Grant MEMPHIS.

  14. Macromolecular sensing at the liquid-liquid interface

    Energy Technology Data Exchange (ETDEWEB)

    Herzog, Gregoire; Flynn, Shane [Tyndall National Institute, Lee Maltings, University College, Cork (Ireland); Arrigan, Damien W M, E-mail: gregoire.herzog@tyndall.ie [Nanochemistry Research Institute, Department of Chemistry, Curtin University, Perth (Australia)

    2011-08-17

    We report here the electrochemical sensing of macromolecules, such as polyLysine dendrimers, at the polarised liquid | liquid interface. Electrochemistry at the liquid | liquid interface is a powerful analytical technique which allows the detection of non-redox active molecules via ion transfer reactions at a polarised water - oil interface. We demonstrate here that different parameters of the polyLysine dendrimers (charge number, molecular weight) have a strong influence on the sensitivity and limit of detection of these macromolecules. This work will help to the development of sensors based on charge transfer at the liquid | liquid interface.

  15. Liquid lubrication in space

    Science.gov (United States)

    Zaretsky, Erwin V.

    1990-01-01

    The requirement for long-term, reliable operation of aerospace mechanisms has, with a few exceptions, pushed the state of the art in tribology. Space mission life requirements in the early 1960s were generally 6 months to a year. The proposed U.S. space station schedule to be launched in the 1990s must be continuously usable for 10 to 20 years. Liquid lubrication systems are generally used for mission life requirements longer than a year. Although most spacecraft or satellites have reached their required lifetimes without a lubrication-related failure, the application of liquid lubricants in the space environment presents unique challenges. The state of the art of liquid lubrication in space as well as the problems and their solutions are reviewed.

  16. Liquid crystals in tribology.

    Science.gov (United States)

    Carrión, Francisco-José; Martínez-Nicolás, Ginés; Iglesias, Patricia; Sanes, José; Bermúdez, María-Dolores

    2009-09-18

    Two decades ago, the literature dealing with the possible applications of low molar mass liquid crystals, also called monomer liquid crystals (MLCs), only included about 50 references. Today, thousands of papers, conference reports, books or book chapters and patents refer to the study and applications of MLCs as lubricants and lubricant additives and efforts are made to develop new commercial applications. The development of more efficient lubricants is of paramount technological and economic relevance as it is estimated that half the energy consumption is dissipated as friction. MLCs have shown their ability to form ordered boundary layers with good load-carrying capacity and to lower the friction coefficients, wear rates and contact temperature of sliding surfaces, thus contributing to increase the components service life and to save energy. This review includes the use of MLCs in lubrication, and dispersions of MLCs in conventional polymers (PDMLCs). Finally, new lubricating system composed of MLC blends with surfactants, ionic liquids or nanophases are considered.

  17. Neutron scattering in liquids

    Energy Technology Data Exchange (ETDEWEB)

    Barocchi, F. [Florence Univ. (Italy). Ist. di Fisica

    1996-12-31

    Together with X-rays, thermal neutrons are the ideal probe to study the microscopic structure of condensed matter, however the precision attainable usually with neutrons for the measurement of atomic position correlation functions in liquids is, at least, one order of magnitude better than for X-rays. In order to measure properly the microscopic dynamics a wide range of momentum transfer with corresponding energy transfer must be available in the range of liquid state excitations. This again is only attainable, with good resolution, with neutrons. (author) 7 figs., 3 refs.

  18. Bicontinuous liquid crystals

    CERN Document Server

    Lynch, Mathew L

    2005-01-01

    PrefaceIntroduction AcknowledgmentsBicontinuous Cubic Liquid Crystalline Materials: A Historical Perspective and Modern Assessment; Kr̄e LarssonIntermediate Phases; Michael C. Holmes and Marc S. LeaverCubic Phases and Human Skin: Theory and Practice; Steven Hoath and Lars NorlňThe Relationship between Bicontinuous Inverted Cubic Phases and Membrane Fusion; D.P. SiegelAspects of the Differential Geometry and Topology of Bicontinuous Liquid-Crystalline Phases; Robert W. CorkeryNovel L3 Phases and Their Macroscopic Properties; R. Beck and H. HoffmannBicontinuous Cubic Phases of Lipids with Entra

  19. Air/liquid collectors

    DEFF Research Database (Denmark)

    Jensen, Søren Østergaard; Olesen, Ole; Kristiansen, Finn Harken

    1997-01-01

    This report determine efficiency equations for combined air/liquid solar collectors by measurements on to different air/liquid collectors. Equations which contain all relevant informations on the solar collectors. A simulation program (Kviksol) has been modified in order to be able to handle...... this kind of collectors. The modified simulation program has been used for the determination of the surplus in performance which solar heating systems with this type of solar collectors for combined preheating of ventilation air and domestic hot water will have. The simulation program and the efficiency...

  20. Modeling of liquid phases

    CERN Document Server

    Soustelle, Michel

    2015-01-01

    This book is part of a set of books which offers advanced students successive characterization tool phases, the study of all types of phase (liquid, gas and solid, pure or multi-component), process engineering, chemical and electrochemical equilibria, and the properties of surfaces and phases of small sizes. Macroscopic and microscopic models are in turn covered with a constant correlation between the two scales. Particular attention has been given to the rigor of mathematical developments. This second volume in the set is devoted to the study of liquid phases.