WorldWideScience

Sample records for liquid chromatography atmospheric

  1. Characterization of typical chemical background interferences in atmospheric pressure ionization liquid chromatography-mass spectrometry

    NARCIS (Netherlands)

    Guo, Xinghua; Bruins, Andries P.; Covey, Thomas R.

    2006-01-01

    The structures and origins of typical chemical background noise ions in positive atmospheric pressure ionization liquid chromatography/mass spectrometry (API LC/MS) are investigated and summarized in this study. This was done by classifying chemical background ions using precursor and product ion sc

  2. Atmospheric pressure chemical ionisation liquid chromatography/mass spectrometry of bacteriochlorophylls from Chlorobiaceae: characteristic fragmentations.

    Science.gov (United States)

    Airs, Ruth L; Keely, Brendan J

    2002-01-01

    Atmospheric pressure chemical ionisation liquid chromatography/mass spectrometry/mass spectrometry (APCI-LC/MS/MS) has been applied to the study of bacteriochlorophylls c, d, and e of phototrophic prokaryotes. Cultures of Chlorobiaceae containing bacteriochlorophyll c, d or e were examined using a high-resolution high-performance liquid chromatography (HPLC) method and APCI-LC/MS/MS employing post-column addition of formic acid. The results reveal complex distributions of bacteriochlorophyll homologues, with some closely eluting species giving isobaric protonated molecules. On-line LC/MS/MS studies reveal characteristic fragment ions for bacteriochlorophylls c, d, and e. Fragmentations involving loss of the extended alkyl substituents that are unique to bacteriochlorophylls c, d and e and their derivatives have been rationalised by studying the phaeophorbides and the results applied to the direct study of the bacteriochlorophylls.

  3. Determination of kava lactones in food supplements by liquid chromatography-atmospheric pressure chemical ionisation tandem mass spectrometry

    NARCIS (Netherlands)

    Bobeldijk, I.; Boonzaaijer, G.; Spies-Faber, E.J.; Vaes, W.H.J.

    2005-01-01

    Reversed-phase liquid chromatography and detection with atmospheric pressure chemical ionisation tandem mass spectrometry was used for the determination of kava extracts in herbal mixtures. One percent of kava extract can be detected, corresponding to approximately 0.05-0.2 mg/g of the individual ka

  4. Accurate quantitation of pentaerythritol tetranitrate and its degradation products using liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry

    NARCIS (Netherlands)

    Brust, H.; Asten, A. van; Koeberg, M.; Dalmolen, J.; Heijden, A.E.D.M. van der; Schoenmakers, P.

    2014-01-01

    After an explosion of pentaerythritol tetranitrate (PETN), its degradation products pentaerythritol trinitrate (PETriN), dinitrate (PEDiN) and mononitrate (PEMN) were detected using liquid chromatography-atmospheric-pressure chemical-ionization-mass spectrometry (LC-APCI-MS). Discrimination between

  5. Atmospheric pressure photoionisation : An ionization method for liquid chromatography-mass spectrometry

    NARCIS (Netherlands)

    Robb, DB; Covey, TR; Bruins, AP

    2000-01-01

    Atmospheric pressure photoionization (APPI) has been successfully demonstrated to provide high sensitivity to LC-MS analysis. A vacuum-ultraviolet lamp designed for photoionization detection in gas chromatography is used as a source of 10-eV photons. The mixture of samples and solvent eluting from a

  6. Capillary liquid chromatography-microchip atmospheric pressure chemical ionization-mass spectrometry.

    Science.gov (United States)

    Ostman, Pekka; Jäntti, Sirkku; Grigoras, Kestas; Saarela, Ville; Ketola, Raimo A; Franssila, Sami; Kotiaho, Tapio; Kostiainen, Risto

    2006-07-01

    A miniaturized nebulizer chip for capillary liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry (capillary LC-microchip APCI-MS) is presented. The APCI chip consists of two wafers, a silicon wafer and a Pyrex glass wafer. The silicon wafer has a DRIE etched through-wafer nebulizer gas inlet, an edge capillary insertion channel, a stopper, a vaporizer channel and a nozzle. The platinum heater electrode and pads for electrical connection were patterned on to the Pyrex glass wafer. The two wafers were joined by anodic bonding, creating a microchip version of an APCI-source. The sample inlet capillary from an LC column is directly connected to the vaporizer channel of the APCI chip. The etched nozzle in the microchip forms a narrow sample plume, which is ionized by an external corona needle, and the formed ions are analyzed by a mass spectrometer. The nebulizer chip enables for the first time the use of low flow rate separation techniques with APCI-MS. The performance of capillary LC-microchip APCI-MS was tested with selected neurosteroids. The capillary LC-microchip APCI-MS provides quantitative repeatability and good linearity. The limits of detection (LOD) with a signal-to-noise ratio (S/N) of 3 in MS/MS mode for the selected neurosteroids were 20-1000 fmol (10-500 nmol l(-1)). LODs (S/N = 3) with commercial macro APCI with the same compounds using the same MS were about 10 times higher. Fast heat transfer allows the use of the optimized temperature for each compound during an LC run. The microchip APCI-source provides a convenient and easy method to combine capillary LC to any API-MS equipped with an APCI source. The advantages and potentials of the microchip APCI also make it a very attractive interface in microfluidic APCI-MS.

  7. Observation of different ceramide species from crude cellular extracts by normal-phase high-performance liquid chromatography coupled to atmospheric pressure chemical ionization mass spectrometry

    NARCIS (Netherlands)

    Pettus, BJ; Bielawska, A; Kroesen, BJ; Moeller, PDR; Szulc, ZM; Hannun, YA; Busman, M

    2003-01-01

    Normal-phase high-performance liquid chromatography (NP-HPLC) coupled to atmospheric pressure chemical ionization mass spectrometry (APCI-MS) allows qualitative analysis of endogenous ceramide and dihydroceramide species from crude lipid extracts utilizing chromatographic methods readily adaptable

  8. Liquid Chromatography in 1982.

    Science.gov (United States)

    Freeman, David H.

    1982-01-01

    Reviews trends in liquid chromatography including apparatus, factors affecting efficient separation of a mixture (peak sharpness and speed), simplified problem-solving, adsorption, bonded phase chromatography, ion selectivity, and size exclusion. The current trend is to control chemical selectivity by the liquid phase. (Author/JN)

  9. Column Liquid Chromatography.

    Science.gov (United States)

    Majors, Ronald E.; And Others

    1984-01-01

    Reviews literature covering developments of column liquid chromatography during 1982-83. Areas considered include: books and reviews; general theory; columns; instrumentation; detectors; automation and data handling; multidimensional chromatographic and column switching techniques; liquid-solid chromatography; normal bonded-phase, reversed-phase,…

  10. Quantitative determination of acetylcholine in microdialysis samples using liquid chromatography/atmospheric pressure spray ionization mass spectrometry.

    Science.gov (United States)

    Keski-Rahkonen, Pekka; Lehtonen, Marko; Ihalainen, Jouni; Sarajärvi, Timo; Auriola, Seppo

    2007-01-01

    A fast, simple and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed for the determination of acetylcholine in rat brain microdialysis samples. The chromatographic separation was achieved in 3 min on a reversed-phase column with isocratic conditions using a mobile phase containing 2% (v/v) of acetonitrile and 0.05% (v/v) of trifluoroacetic acid (TFA). A stable isotope-labeled internal standard was included in the analysis and detection was carried out with a linear ion trap mass spectrometer using selected reaction monitoring (SRM). Analyte ionization was performed with an atmospheric pressure chemical ionization (APCI) source without applying discharge current (atmospheric pressure spray ionization). This special ionization technique offered significant advantages over electrospray ionization for the analysis of acetylcholine with reversed-phase ion-pairing chromatography. The lower limit of quantification was 0.15 nM (1.5 fmol on-column) and linearity was maintained over the range of 0.15-73 nM, providing a concentration range that is significantly wider than that of the existing LC/MS methods. Good accuracy and precision were obtained for concentrations within the standard curve range. The method was validated and has been used extensively for the determination of acetylcholine in rat brain microdialysis samples.

  11. Comparative analysis of different plant oils by high-performance liquid chromatography-atmospheric pressure chemical ionization mass spectrometry.

    Science.gov (United States)

    Jakab, Annamaria; Héberger, Károly; Forgács, Esther

    2002-11-01

    Different vegetable oil samples (almond, avocado, corngerm, grapeseed, linseed, olive, peanut, pumpkin seed, soybean, sunflower, walnut, wheatgerm) were analyzed using high-performance liquid chromatography-atmospheric pressure chemical ionization mass spectrometry. A gradient elution technique was applied using acetone-acetonitrile eluent systems on an ODS column (Purospher, RP-18e, 125 x 4 mm, 5 microm). Identification of triacylglycerols (TAGs) was based on the pseudomolecular ion [M+1]+ and the diacylglycerol fragments. The positional isomers of triacylglycerol were identified from the relative intensities of the [M-RCO2]+ fragments. Linear discriminant analysis (LDA) as a common multivariate mathematical-statistical calculation was successfully used to distinguish the oils based on their TAG composition. LDA showed that 97.6% of the samples were classified correctly.

  12. Novel determination of polychlorinated naphthalenes in water by liquid chromatography-mass spectrometry with atmospheric pressure photoionization.

    Science.gov (United States)

    Moukas, Athanasios I; Thomaidis, Nikolaos S; Calokerinos, Antony C

    2016-01-01

    This study presents the development, optimization, and validation of a novel method for the determination of polychlorinated naphthalenes (PCNs) by liquid chromatography-atmospheric pressure photoionization (APPI), using toluene as dopant. The mass spectra of PCN 52, 54, 66, 67, 73, and 75 were recorded in negative ionization. The base ions corresponded to [M-Cl+O](-), where M is the analyte molecule. A strategy, which includes designs of experiments, for the development, the evaluation, and the optimization of the LC-APPI-MS/MS methods is also described. Finally, a highly sensitive method with low instrumental limits of detection (LoDs), ranging from 0.8 pg for PCN 75 to 16 pg for PCN 54 on column, was validated. A Thermo Hypersil Green PAH (100 mm × 2.1 mm, 3 μm) column was used with acetonitrile/water/methanol as mobile phase. The method was applied for the determination of the selected PCNs in surface and tap water samples. A simple liquid-liquid extraction method for the extraction of PCNs from water samples was used. Method LoQs ranged from 29 ng L(-1), for PCN 73, to 63 ng L(-1), for PCN 54, and the recoveries ranged from 97 to 99%, for all congeners. This is the first LC-APPI-MS/MS method for the determination of PCNs in water samples.

  13. Determination of neonicotinoid insecticides and strobilurin fungicides in particle phase atmospheric samples by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Raina-Fulton, Renata

    2015-06-01

    A liquid chromatography-tandem mass spectrometry method has been developed for the determination of neonicotinoids and strobilurin fungicides in the particle phase fraction of atmosphere samples. Filter samples were extracted with pressurized solvent extraction, followed by a cleanup step with solid phase extraction. Method detection limits for the seven neonicotinoid insecticides and six strobilurin fungicides were in the range of 1.0-4.0 pg/m(3). Samples were collected from June to September 2013 at two locations (Osoyoos and Oliver) in the southern Okanagan Valley Agricultural Region of British Columbia, where these insecticides and fungicides are recommended for use on tree fruit crops (apples, pears, cherries, peaches, apricots) and vineyards. This work represents the first detection of acetamiprid, imidacloprid, clothianidin, kresoxim-methyl, pyraclostrobin, and trifloxystrobin in particle phase atmospheric samples collected in the Okanagan Valley in Canada. The highest particle phase atmospheric concentrations were observed for imidacloprid, pyraclostrobin, and trifloxystrobin at 360.0, 655.6, and 1908.2 pg/m(3), respectively.

  14. Characterization of the chemical composition of a block copolymer by liquid chromatography/mass spectrometry using atmospheric pressure chemical ionization and electrospray ionization

    NARCIS (Netherlands)

    Leeuwen, van Suze M.; Tan, BoonHua; Grijpma, Dirk W.; Feijen, J.; Karst, Uwe

    2007-01-01

    Liquid chromatography/mass spectrometry (LC/MS) with electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) in the positive and negative ion modes was used for the characterization of a block copolymer consisting of methoxy poly(ethylene oxide) (mPEO), an -caprolactone (CL

  15. Characterization of the chemical composition of a block copolymer by liquid chromatography/mass spectrometry using atmospheric pressure chemical ionization and electrospray ionization

    NARCIS (Netherlands)

    van Leeuwen, Suze M.; Tan, BoonHua; Grijpma, Dirk W.; Fejen, Jan; Karst, Uwe

    2007-01-01

    Liquid chromatography/mass spectrometry (LC/MS) with electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) in the positive and negative ion modes was used for the characterization of a block copolymer consisting of methoxy poly(ethylene oxide) (mPEO), an epsilon-caprolact

  16. High Performance Liquid Chromatography

    Science.gov (United States)

    Talcott, Stephen

    High performance liquid chromatography (HPLC) has many applications in food chemistry. Food components that have been analyzed with HPLC include organic acids, vitamins, amino acids, sugars, nitrosamines, certain pesticides, metabolites, fatty acids, aflatoxins, pigments, and certain food additives. Unlike gas chromatography, it is not necessary for the compound being analyzed to be volatile. It is necessary, however, for the compounds to have some solubility in the mobile phase. It is important that the solubilized samples for injection be free from all particulate matter, so centrifugation and filtration are common procedures. Also, solid-phase extraction is used commonly in sample preparation to remove interfering compounds from the sample matrix prior to HPLC analysis.

  17. Micellar liquid chromatography

    Science.gov (United States)

    Basova, Elena M.; Ivanov, Vadim M.; Shpigun, Oleg A.

    1999-12-01

    Background and possibilities of practical applications of micellar liquid chromatography (MLC) are considered. Various retention models in MLC, the effects of the nature and concentration of surfactants and organic modifiers, pH, temperature and ionic strength on the MLC efficiency and selectivity are discussed. The advantages and limitations of MLC are demonstrated. The performance of MLC is critically evaluated in relationship to the reversed-phase HPLC and ion-pair chromatography. The potential of application of MLC for the analysis of pharmaceuticals including that in biological fluids and separation of inorganic anions, transition metal cations, metal chelates and heteropoly compounds is described. The bibliography includes 146 references.

  18. Analysis of wax ester molecular species by high performance liquid chromatography/atmospheric pressure chemical ionisation mass spectrometry.

    Science.gov (United States)

    Vrkoslav, Vladimír; Urbanová, Klára; Cvacka, Josef

    2010-06-18

    High chromatographic resolution of wax esters (WEs) was achieved by non-aqueous reversed-phase liquid chromatography on a Nova-Pak C18 column by optimising the acetonitrile/ethyl acetate mobile phase gradient. The retention behaviour of WEs was studied in this chromatographic system. The WEs eluted according to their equivalent carbon number (ECN) values; within the group of WEs with the identical ECN, the most unsaturated species tended to elute first. The isobaric WEs with different positions of the ester moiety were separated from each other whenever the lengths of the chains were sufficiently different. The methyl-branched esters eluted at shorter retention times than the straight-chained analogues, and the resolution among methyl-branched WEs depended on the position of the branching. The analytes were detected by atmospheric pressure chemical ionisation mass spectrometry (APCI-MS) using data-dependent scanning. WEs provided simple full-scan spectra with abundant protonated molecules and low-intensity fragments. Collision-induced dissociation (CID) promoted identification of the WE molecular species. The responses of WEs were found to be dependent on the number of double bonds and on the alkyl-chain length; the limits of the detection ranged from 20micromol/L to 200nmol/L. The HPLC/APCI-MS was applied for the analysis of the WEs isolated from honeycomb beeswax, jojoba oil and human hair. Good agreement between reported results and the literature data was achieved, with several novel polyunsaturated WEs also being found.

  19. Principles of Liquid Chromatography

    Science.gov (United States)

    Bakalyar, Stephen R.

    This article reviews the basic principles of high performance liquid chromatography (HPLC). The introductory section provides an overview of the HPLC technique, placing it in historical context and discussing the elementary facts of the separation mechanism. The next section discusses the nature of resolution, describing the two principal aspects, zone center separation and zone spreading. The third section takes a detailed look at how HPLC is used in practice to achieve a separation. It discusses the three key variables that need to be adjusted: retention, efficiency, and selectivity. A fourth section is concerned with various relationships of practical importance: flow rate, temperature, and pressure. A final section discusses future trends in HPLC.

  20. Quantitation of triacylglycerols in edible oils by off-line comprehensive two-dimensional liquid chromatography-atmospheric pressure chemical ionization mass spectrometry using a single column.

    Science.gov (United States)

    Wei, Fang; Hu, Na; Lv, Xin; Dong, Xu-Yan; Chen, Hong

    2015-07-24

    In this investigation, off-line comprehensive two-dimensional liquid chromatography-atmospheric pressure chemical ionization mass spectrometry using a single column has been applied for the identification and quantification of triacylglycerols in edible oils. A novel mixed-mode phenyl-hexyl chromatographic column was employed in this off-line two-dimensional separation system. The phenyl-hexyl column combined the features of traditional C18 and silver-ion columns, which could provide hydrophobic interactions with triacylglycerols under acetonitrile conditions and can offer π-π interactions with triacylglycerols under methanol conditions. When compared with traditional off-line comprehensive two-dimensional liquid chromatography employing two different chromatographic columns (C18 and silver-ion column) and using elution solvents comprised of two phases (reversed-phase/normal-phase) for triacylglycerols separation, the novel off-line comprehensive two-dimensional liquid chromatography using a single column can be achieved by simply altering the mobile phase between acetonitrile and methanol, which exhibited a much higher selectivity for the separation of triacylglycerols with great efficiency and rapid speed. In addition, an approach based on the use of response factor with atmospheric pressure chemical ionization mass spectrometry has been developed for triacylglycerols quantification. Due to the differences between saturated and unsaturated acyl chains, the use of response factors significantly improves the quantitation of triacylglycerols. This two-dimensional liquid chromatography-mass spectrometry system was successfully applied for the profiling of triacylglycerols in soybean oils, peanut oils and lord oils. A total of 68 triacylglycerols including 40 triacylglycerols in soybean oils, 50 triacylglycerols in peanut oils and 44 triacylglycerols in lord oils have been identified and quantified. The liquid chromatography-mass spectrometry data were analyzed

  1. On-line enrichment and determination of polycyclic aromatic hydrocarbons in atmospheric particulates using high performance liquid chromatography with fluorescence as detector

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Seven polycyclic aromatic hydrocarbons (PAHs) in atmospheric particulates were determinated by high performance liquid chromatography (HPLC) with fluorescence detector using direction injection and an on-line enrichment trap column. The method simplified the sample pretreatment, saved time and increased the efficiency. With the on-line trap column, PAHs were separated availably even underground injecting 1.0 ml sample with relatively high column efficiency. The recoveries of the seven PAHs were from 85% to 120% for spiked atmospheric particulate sample. The limit of detection was 15.3-39.6 ng/L (S/N=3.3). There were good linear correlations between the peak areas and concentrations of the seven kinds of PAHs in the range of 1-50 ng/ml with the correlation coefficients over 0.9970. Furthermore, it also indicated that the method is available to determine PAHs in atmospheric particulates well.

  2. Ultrapressure liquid chromatography-tandem mass spectrometry assay using atmospheric pressure photoionization (UPLC-APPI-MS/MS) for quantification of 4-methoxydiphenylmethane in pharmacokinetic evaluation.

    Science.gov (United States)

    Farhan, Nashid; Fitzpatrick, Sean; Shim, Yun M; Paige, Mikell; Chow, Diana Shu-Lian

    2016-09-05

    4-Methoxydiphenylmethane (4-MDM), a selective augmenter of Leukotriene A4 Hydrolase (LTA4H), is a new anti-inflammatory compound for potential treatment of chronic obstructive pulmonary disease (COPD). Currently, there is no liquid chromatography tandem mass spectrometric (LC-MS/MS) method for the quantification of 4-MDM. A major barrier for developing the LC-MS/MS method is the inability of electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) to ionize 4-MDM due to its hydrophobicity and lack of any functional group for ionization. With the advent of atmospheric pressure photoionization (APPI) technique, many hydrophobic compounds have been demonstrated to ionize by charge transfer reactions. In this study, a highly sensitive ultrapressure liquid chromatography tandem mass spectrometry assay using atmospheric pressure photoionization (UPLC-APPI-MS/MS) for the quantifications of 4-MDM in rat plasma has been developed and validated. 4-MDM was extracted from the plasma by solid phase extraction (SPE) and separated chromatographically using a reverse phase C8 column. The photoionization (PI) was achieved by introducing anisole as a dopant to promote the reaction of charge transfer. The assay with a linear range of 5 (LLOQ)-400ngmL(-1) met the regulatory requirements for accuracy, precision and stability. The validated assay was employed to quantify the plasma concentrations of 4-MDM after an oral dosing in Sprague Dawley (SD) rats.

  3. Fast analysis of 29 polycyclic aromatic hydrocarbons (PAHs) and nitro-PAHs with ultra-high performance liquid chromatography-atmospheric pressure photoionization-tandem mass spectrometry

    OpenAIRE

    Shih-Chun Candice Lung; Chun-Hu Liu

    2015-01-01

    Polycyclic aromatic hydrocarbons (PAHs) and nitro-PAHs are ubiquitous in the environment. Some of them are probable carcinogens and some are source markers. This work presents an ultra-high performance liquid chromatography-atmospheric pressure photoionization-tandem mass spectrometry (UHPLC-APPI-MS/MS) method for simultaneous analysis of 20 PAHs and nine nitro-PAHs. These compounds are separated in 15 minutes in the positive mode and 11 minutes in the negative mode, one half of GC/MS analysi...

  4. Introduction to modern liquid chromatography

    National Research Council Canada - National Science Library

    Snyder, Lloyd R; Kirkland, J. J; Dolan, John W

    2010-01-01

    "High-performance liquid chromatography (HPLC) is today the leading technique for chemical analysis and related applications, with an ability to separate, analyze, and/or purify virtually any sample...

  5. Quantification of achiral and chiral methylsulfonyl polychlorinated biphenyl metabolites by column-switching liquid chromatography-atmospheric pressure photoionization-tandem mass spectrometry.

    Science.gov (United States)

    Cooper, Victoria I; Letcher, Robert J; Dietz, Rune; Sonne, Christian; Wong, Charles S

    2012-12-14

    An enantioselective heart-cut column-switching liquid chromatography-atmospheric pressure photoionization-tandem mass spectrometry method was developed for the analysis of 25 methylsulfonyl polychlorinated biphenyl metabolites in tissue extracts. Use of a pyrenyl-ethyl silica column in the first dimension enabled separation of all but two pairs of isobaric analytes. Enantioseparation was achieved for 9 out of the 10 atropisomeric analytes using a Chiralpak AD-H amylose-based column within 93 min, resulting in greater chromatographic resolution of enantioseparation over shorter analysis time by up to a factor of three, compared to previous one-dimensional and multi-dimensional gas chromatography-based methods. Precision for concentration and enantiomer fraction measurements was within 11% and 3% relative standard deviation, respectively. Limits of detection ranged from 0.01 to 1.73 ng on-column. Meta-congeners had poorer sensitivity (i.e., ng on-column), consistent with existing gas chromatography-based methods. Despite this limitation, the method was successfully applied to the analysis of Greenland sledge dog adipose tissue extracts, which had highly non-racemic residues of 4-methylsulfonyl-2,2',3,5',6-pentachlorobiphenyl and 4'-methylsulfonyl-2,2',3,3',4,6'-hexachlorobiphenyl, consistent with past reports in Arctic mammals.

  6. Quantification of levoglucosan and its isomers by High Performance Liquid Chromatography - Electrospray Ionization tandem Mass Spectrometry and its applications to atmospheric and soil samples

    Science.gov (United States)

    Piot, C.; Jaffrezo, J.-L.; Cozic, J.; Pissot, N.; El Haddad, I.; Marchand, N.; Besombes, J.-L.

    2012-01-01

    The determination of atmospheric concentrations of levoglucosan and its two isomers, unambiguous tracers of biomass burning emissions, became even more important with the development of wood as renewable energy for domestic heating. Many researches demonstrated the increase during recent years of atmospheric particulate matter load due to domestic biomass combustion in developed countries. Analysis of biomass burning tracers is traditionally performed with Gas Chromatography-Mass Spectrometry (GC-MS) technique after derivatization and requires an organic solvent extraction. A simpler and faster technique using Liquid Chromatography - Electrospray Ionisation - tandem Mass Spectrometry (LC-ESI-MS/MS) was optimized for the analysis of levoglucosan, mannosan and galactosan isomers after an aqueous extraction. This technique allows a good separation between the three compounds in a very reduced time (runtime ~5 min). LOD and LOQ of this method are 30 μg l-1 and 100 μg l-1 respectively, allowing the use of filters from low-volume sampler (as commonly used in routine campaigns). A comparison of simultaneous levoglucosan measurements by GC-MS and LC-ESI-MS/MS for about 50 samples coming from different types of sampling sites and seasons was realized and shows very good agreement between the two methods. Therefore LC-ESI-MS/MS method can be used as an alternative to GC-MS particularly for measurement campaigns in routine where analysis time is important and detection limit is reduced. This paper shows that this method is also applicable to other environmental sample types like soil.

  7. Rapid simultaneous determination of o-phenylphenol, diphenyl, thiabendazole, imazalil and its major metabolite in citrus fruits by liquid chromatography-mass spectrometry using atmospheric pressure photoionization.

    Science.gov (United States)

    Yoshioka, Naoki; Akiyama, Yumi; Teranishi, Kiyoshi

    2004-01-02

    A simple and rapid simultaneous analytical method of four post-harvest fungicides, o-phenylphenol (OPP), diphenyl (DP), thiabendazole (TBZ), imazalil (IMZ) and its major metabolite R14821 (IMZ-M) in citrus fruits was developed. These compounds were extracted under basic conditions with diethyl ether. The organic layer was washed with water and evaporated at moderate pressure adding methanol. These compounds were determined by liquid chromatography-mass spectrometry (LC-MS) using atmospheric pressure photoionization (APPI). The recoveries of the five compounds added to citrus fruits at 1 microg/g ranged from 67 to 100%, with relative standard deviations (R.S.D.) ranging from 2 to 8%. The detection limits (S/N = 3) were 0.01 microg/g and 0.05 microg/g (DP).

  8. Analysis of oxysterols and vitamin D metabolites in mouse brain and cell line samples by ultra-high-performance liquid chromatography-atmospheric pressure photoionization-mass spectrometry.

    Science.gov (United States)

    Ahonen, Linda; Maire, Florian B R; Savolainen, Mari; Kopra, Jaakko; Vreeken, Rob J; Hankemeier, Thomas; Myöhänen, Timo; Kylli, Petri; Kostiainen, Risto

    2014-10-17

    We have developed an ultra-high-performance liquid chromatography-atmospheric pressure photoionization-tandem mass spectrometric (UHPLC-APPI-MS/MS) method for the simultaneous quantitative analyses of several oxysterols and vitamin D metabolites in mouse brain and cell line samples. An UHPLC-APPI-high resolution mass spectrometric (UHPLC-APPI-HRMS) method that uses a quadrupole-time of flight mass spectrometer was also developed for confirmatory analysis and for the identification of non-targeted oxysterols. Both methods showed good quantitative performance. Furthermore, APPI provides high ionization efficiency for determining oxysterols and vitamin D related compounds without the time consuming derivatization step needed in the conventionally used electrospray ionization method to achieve acceptable sensitivity. Several oxysterols were quantified in mouse brain and cell line samples. Additionally, 25-hydroxyvitamin D3 was detected in mouse brain samples for the first time.

  9. Trace determination of 13 haloacetamides in drinking water using liquid chromatography triple quadrupole mass spectrometry with atmospheric pressure chemical ionization.

    Science.gov (United States)

    Chu, Wenhai; Gao, Naiyun; Yin, Daqiang; Krasner, Stuart W; Templeton, Michael R

    2012-04-27

    The haloacetamides (HAcAms) are disinfection by-products (DBPs) in drinking water which are currently receiving increased scientific attention due to their elevated toxicity relative to regulated disinfection by-products. A simultaneous determination method of 13 HAcAms, combining solid-phase extraction (SPE) enrichment, liquid chromatographic (LC) separation, and triple quadrupole mass spectrometry (tqMS) detection with atmospheric pressure chemical ionization (APCI) using selective reaction monitoring in positive mode, was developed to measure HAcAms, including chlorinated, brominated, and iodinated analogs. Ammonium chloride and Oasis HLB were selected as the dechlorinating reagent and polymeric SPE sorbent of HAcAm samples. The used tqMS apparatus showed higher sensitivity for the studied HAcAms in the APCI mode than electrospray ionization. 13 HAcAms were separated by LC in 9.0 min, and the detection limits ranged from 7.6 to 19.7 ng/L. The SPE-LC/tqMS method was successfully applied to quantify 13 HAcAms in drinking water samples for the first time, and first indentified tribromoacetamide and chloroiodoacetamide as DBPs in drinking water.

  10. Two-dimensional liquid chromatography

    DEFF Research Database (Denmark)

    Græsbøll, Rune

    of this thesis is on online comprehensive two-dimensional liquid chromatography (online LC×LC) with reverse phase in both dimensions (online RP×RP). Since online RP×RP has not been attempted before within this research group, a significant part of this thesis consists of knowledge and experience gained...

  11. Separation of whey proteins for chromatography liquid

    OpenAIRE

    Abraham D. Giraldo Zuñiga; Edwin E.García Rojas; Jane S. R. Coimbra; Wilmer E. Luera Peña

    2010-01-01

    This paper describes and compares three chromatographic methods for the analysis and quantification of most abundant proteins in cheese whey, -lactalbumin and -lactoglobulin. The methods were: Reverse-phase high performance liquid chromatography, anion Exchange chromatography and size-exclusion chromatography. The reverse- phase liquid chromatography led to a better separation of whey proteins than size-exclusion chromatography and anion exchange chromatography, this method offered an excel...

  12. Liquid chromatography for determination of disulfiram in workplace atmosphere%工作场所空气中双硫醒测定的液相色谱法

    Institute of Scientific and Technical Information of China (English)

    傅胜; 韩志辉; 余克平; 高寿泉

    2015-01-01

    Objective To establish a method for determination of disulfiram in the workplace atmosphere by liquid chromatography.Methods Sampling with glass fiber filter,eluting with methanol,separating with C18 column,and determination with liquid chromatography.Results The bearing capacity of glass fiber filter exceeded 3.45 mg per piece.The elution efficiency was 97.8%~101.0% The relative standard deviation varied from 1.09% to 1.44%.The limit of detection was 0.1 μg/ml.The minimum detectable concentration was 0.011 mg/m3 (with sampled air volume of 45 L).Conclusion The method has high selectivity,accuracy,and precision and strong applicability.%目的 建立工作场所空气中双硫醒测定的液相色谱法.方法 玻璃纤维滤膜采样、甲醇洗脱,C18柱进行分离,液相色谱法测定.结果 玻璃纤维滤膜采样承载量>3.45 mg/张,洗脱效率为97.8%~101.0%,方法相对标准偏差(RSD)为1.09%~1.44%,检出限为0.1 μg/ml,最低检出浓度为0.011mg/m3(以采集45 L空气样品计).结论 该方法选择性好,准确度和精密度高,适用性强.

  13. Quantification of levoglucosan and its isomers by High Performance Liquid Chromatography – Electrospray Ionization tandem Mass Spectrometry and its applications to atmospheric and soil samples

    Directory of Open Access Journals (Sweden)

    C. Piot

    2011-07-01

    Full Text Available The determination of atmospheric concentrations of levoglucosan and its two isomers, unambiguous tracers of biomass burning emissions, became even more important with the development of wood as renewable energy for domestic heating. Many researches demonstrated the increase during recent years of atmospheric particulate matter load due to domestic biomass combustion in developed countries. Analysis of biomass burning tracers is traditionally performed with Gas Chromatography-Mass Spectrometry (GC-MS technique after derivatization and requires an organic solvent extraction. A simpler and faster technique using Liquid Chromatography – Electrospray Ionisation – tandem Mass Spectrometry (LC-ESI-MS/MS was optimized for the analysis of levoglucosan, mannosan and galactosan isomers after an aqueous extraction. This technique allows a good separation between the three compounds in a very reduced time (runtime ~5 min. LOD and LOQ of this method are 30 μg l−1 and 100 μg l−1 respectively, allowing the use of filters from low-volume sampler (as commonly used in routine campaigns. A comparison of simultaneous levoglucosan measurements by GC-MS and LC-ESI-MS/MS for about 50 samples coming from different types of sampling sites and seasons was realized and shows very good agreement between the two methods. Therefore LC-ESI-MS/MS method can be used as an alternative to GC-MS particularly for measurement campaigns in routine where analysis time is important and detection limit is reduced. This paper shows that this method is also applicable to other environmental sample types like soil.

  14. Technical report Development of a piezoelectric inkjet dopant delivery device for an atmospheric pressure photoionization source with liquid chromatography/mass spectrometry

    KAUST Repository

    Amad, Maan H.

    2013-01-01

    This paper describes a simple robust and integrated piezoelectric actuated printhead as a dopant delivery system for atmospheric pressure photoionization with liquid chromatography/mass spectrometry The newly designed dopant delivery system avoids problems associated with traditional liquid delivery systems such as solvent immiscibility backpressure and increased post-column dead volume issues The performance of the new device was tested and evaluated using chlorobenzene as a dopant with a test mixture consisting of 18 different polycyclic aromatic hydrocarbons (PAHs) The results show that the new system works robustly at low dopant consumption level (16 uL min-1) consuming only approximately 5% of the amount used by conventional sources The low dopant consumption has resulted in up to a 20-fold reduction in signal intensity of tested PAH molecules but has led to less presence of background cluster ions and dopant trace contaminant background ions in the source area Consequently all tested PAHs were detected with excellent signal-to-noise ratio with at least two-to ten-fold improvements in the limit of detection and quantification compared to those obtained with traditional dopant assistance using a post-column addition method © IM Publications LLP 2013.

  15. A liquid chromatography-atmospheric pressure photoionization tandem mass spectrometric (LC-APPI-MS/MS) method for the determination of triterpenoids in medicinal plant extracts.

    Science.gov (United States)

    Gobo, Luciana Assis; Viana, Carine; Lameira, Osmar Alves; de Carvalho, Leandro Machado

    2016-08-01

    An analytical method using liquid chromatography-atmospheric pressure photoionization tandem mass spectrometry with toluene as a dopant was developed for the determination of triterpenes in medicinal plant extracts. The 12 compounds determined have been shown to exhibit biological activity, such as gastroprotective, hepatoprotective, anti-inflammatory, antiviral and anti-tumor effects. The parameters of the atmospheric pressure photoionization interface were optimized to obtain the highest possible sensitivity for all of the compounds. The limits of detection and quantification ranged from 0.4 to 157.9 µg l(-1) and 1.3 to 526.4 µg l(-1) , respectively. The method was validated and applied to extracts of five medicinal plants species (Mansoa alliacea (Lam.) A.H.Gentry, Bauhinia variegata var variegata, Bauhinia variegata var alboflava, Cecropia obtuse Trécul and Cecropia palmate Willd) from the Amazonian region. The concentrations of the six triterpenes quantified in the samples ranged from 0.424 mg kg(-1) for ursolic acid to 371.96 mg kg(-1) for β-amyrin, which were quantified by using the standard addition method (n = 3). Copyright © 2016 John Wiley & Sons, Ltd.

  16. Determination of polycyclic aromatic hydrocarbons in fractions in asphalt mixtures using liquid chromatography coupled to mass spectrometry with atmospheric pressure chemical ionization.

    Science.gov (United States)

    Nascimento, Paulo Cicero; Gobo, Luciana Assis; Bohrer, Denise; Carvalho, Leandro Machado; Cravo, Margareth Coutinho; Leite, Leni Figueiredo Mathias

    2015-07-01

    An analytical method using liquid chromatography coupled to mass spectrometry with atmospheric pressure chemical ionization for the determination of polycyclic aromatic hydrocarbons in asphalt fractions has been developed. The 14 compounds determined, characterized by having two or more condensed aromatic rings, are expected to be present in asphalt and are considered carcinogenic and mutagenic. The parameters of the atmospheric pressure chemical ionization interface were optimized to obtain the highest possible sensitivity for all of the compounds. The limits of detection ranged from 0.5 to 346.5 μg/L and the limits of quantification ranged from 1.7 to 1550 μg/L. The method was validated against a diesel particulate extract standard reference material (NIST SRM 1975), and the obtained concentrations agreed with the certified values. The method was applied to asphalt samples after its fractionation according to ASTM D4124 and the method of Green. The concentrations of the seven polycyclic aromatic hydrocarbons quantified in the sample ranged from 0.86 mg/kg for benzo[ghi]perylene to 98.32 mg/kg for fluorene.

  17. Multicomponent mixed dopant optimization for rapid screening of polycyclic aromatic hydrocarbons using ultra high performance liquid chromatography coupled to atmospheric pressure photoionization high-resolution mass spectrometry

    KAUST Repository

    Sioud, Salim

    2012-05-04

    RATIONALE To enhance the ionization efficiencies in atmospheric pressure photoionization mass spectrometry a dopant with favorable ionization energy such as chlorobenzene is typically used. These dopants are typically toxic and difficult to mix with water-soluble organic solvents. In order to achieve a more efficient and less toxic dopant, a multicomponent mixed dopant was explored. METHODS A multicomponent mixed dopant for non-targeted rapid screening of polycyclic aromatic hydrocarbons (PAHs) was developed and optimized using ultra high performance liquid chromatography (UPLC) coupled to atmospheric pressure photoionization high-resolution mass spectrometry. Various single and multicomponent mixed dopants consisting of ethanol, chlorobenzene, bromobenzene, anisole and toluene were evaluated. RESULTS Fourteen out of eighteen PAHs were successfully separated and detected at low pg/μL levels within 5 min with high mass accuracy ≤4 ppm. The optimal mixed multicomponent dopant consisted of ethanol/chlorobenzene/bromobenzene/anisole (98.975:0.1:0.9:0.025, v/v %) and it improved the limit of detection (LOD) by 2- to 10-fold for the tested PAHs compared to those obtained with pure chlorobenzene. CONCLUSIONS A novel multicomponent dopant that contains 99% ethanol and 1% mixture of chlorobenzene, bromobenzene and anisole was found to be an effective dopant mixture to ionize PAHs. The developed UPLC multicomponent dopant assisted atmospheric pressure photoionization high-resolution mass spectrometry offered a rapid non targeted screening method for detecting the PAHs at low pg/;μL levels within a 5 min run time with high mass accuracy a;circ4 ppm. Copyright © 2012 John Wiley & Sons, Ltd.

  18. Stability studies of propoxur herbicide in environmental water samples by liquid chromatography-atmospheric pressure chemical ionization ion-trap mass spectrometry.

    Science.gov (United States)

    Sun, Lei; Lee, Hian Kee

    2003-10-01

    Liquid chromatography-atmospheric pressure ionization ion-trap mass spectrometry has been investigated for the analysis of polar pesticides in water. The degradation behavior of propoxur, selected as a model pesticide belonging to the N-methylcarbamate group, in various aqueous matrices (Milli-Q water, drinking water, rain water, seawater and river water) was investigated. Two interfaces of atmospheric pressure ionization, atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI), were compared during the study. Propoxur and its transformation product (N-methylformamide) were best ionized as positive ions with both APCI and ESI, while another transformation product (2-isopropoxyphenol) yielded stronger signals as negative ions only with APCI. In addition, the effects of various pH, matrix type and irradiation sources (sunlight, darkness, indoor lighting and artificial UV lamp) on the chemical degradation (hydrolysis) were also assessed. From the kinetic studies of degradation, it was found that the half-life of propoxur was reduced from 327 to 161 h in Milli-Q water with variation of irradiation conditions from dark to sunlight exposure. Degradation rates largely increased with increasing pH. The half-life of the target compound dissolved in Milli-Q water under darkness decreased from 407 to 3 h when the pH of Milli-Q water was increased from 5 to 8.5. These suggest that hydrolysis of propoxur is light-intensity and pH-dependent. In order to mimic contaminated natural environmental waters, propoxur was spiked into real water samples at 30 microg/l. The degradation of propoxur in such water samples under various conditions were studied in detail and compared. With the ion trap run in a time-scheduled single ion monitoring mode, typical limits of detection of the instrument were in the range of 1-10 microg/l.

  19. Normal phase liquid chromatography coupled to quadrupole time of flight atmospheric pressure chemical ionization mass spectrometry for separation, detection and mass spectrometric profiling of neutral sphingolipids and cholesterol.

    Science.gov (United States)

    Farwanah, Hany; Wirtz, Jennifer; Kolter, Thomas; Raith, Klaus; Neubert, Reinhard H H; Sandhoff, Konrad

    2009-10-01

    Many lipidomic approaches focus on investigating aspects of sphingolipid metabolism. Special emphasis is put on neutral sphingolipids and cholesterol and their interaction. Such an interest is attributed to the fact that those lipids are altered in a series of serious disorders including various sphingolipidoses. High performance thin-layer chromatography (HPTLC) has become a widely used technique for lipid analysis. However, mass spectrometric profiling is irreplaceable for gaining an overview about the various molecular species within a lipid class. In this work we have developed a sensitive method based on a gradient normal phase high performance liquid chromatography (HPLC) coupled to quadrupole time of flight (QTOF) atmospheric pressure chemical ionization mass spectrometry (APCI-MS) in positive mode, which for the first time enables separation, on-line detection, and mass spectrometric profiling of multiple neutral sphingolipids including ceramide, glucosylceramide, lactosylceramide, globotriaosylceramide, globotetraosylceramide, sphingomyelin as well as cholesterol within less than 15min. An important advantage of the presented HPLC/APCI-MS approach is that the separation pattern emulates the one obtained by an optimized HPTLC method with a multiple stage development. Thus, the lipid classes previously separated and quantified by HPTLC can be easily screened regarding their mass spectrometric profiles by HPLC/APCI-MS. In addition, the selected ionization conditions enable in-source fragmentation providing useful structural information. The methods (HPLC/APCI-MS and the optimized HPTLC) were applied for the analysis of the mentioned lipids in human fibroblasts. This approach is aimed basically at investigators who perform studies based on genetic modifications or treatment with pharmacological agents leading to changes in the biochemical pathways of neutral sphingolipids and cholesterol. In addition, it can be of interest for research on disorders related to

  20. A liquid chromatography-atmospheric pressure photoionization tandem mass spectrometric method for the determination of organosulfur compounds in petroleum asphalt cements.

    Science.gov (United States)

    da Silveira, Géssica Domingos; Faccin, Henrique; Claussen, Luis; Goularte, Rayane Bueno; Do Nascimento, Paulo C; Bohrer, Denise; Cravo, Margareth; Leite, Leni F M; de Carvalho, Leandro Machado

    2016-07-29

    We present a sensitive liquid chromatography-atmospheric pressure photoionization tandem mass spectrometric (UHPLC-APPI-MS/MS) method for the determination of selected organosulfur compounds in Brazilian asphalt cements. It was possible to detect 14 organosulfur compounds of different classes where sulfoxides and sulfones presented higher sensibility in ionization than thiophenes and aromatic sulfides. A dopant-assisted APPI method was also tested, however, when chromatographic flow rate was optimized a decrease in signal was observed for all compounds. PAHs were tested and ruled out as possible interfering compounds and the matrix effect of asphalt cements was within an acceptable range for the quantification of organosulfur compounds. The proposed method was found to have satisfactory linearity and accuracy with recoveries between 83.85 and 110.28% for thianaphthene and 3-methylbenzothiophene, respectively. Therefore, the method allowed the characterization of organosulfur compounds in Brazilian asphalt cements and demonstrated changes in the amount quantified in asphaltenic and maltenic fractions after the RTFOT+SUNTEST aging process.

  1. Fast analysis of 29 polycyclic aromatic hydrocarbons (PAHs) and nitro-PAHs with ultra-high performance liquid chromatography-atmospheric pressure photoionization-tandem mass spectrometry

    Science.gov (United States)

    Lung, Shih-Chun Candice; Liu, Chun-Hu

    2015-08-01

    Polycyclic aromatic hydrocarbons (PAHs) and nitro-PAHs are ubiquitous in the environment. Some of them are probable carcinogens and some are source markers. This work presents an ultra-high performance liquid chromatography-atmospheric pressure photoionization-tandem mass spectrometry (UHPLC-APPI-MS/MS) method for simultaneous analysis of 20 PAHs and nine nitro-PAHs. These compounds are separated in 15 minutes in the positive mode and 11 minutes in the negative mode, one half of GC/MS analysis time. Two pairs of precursor/product ions are offered, which is essential for confirmation. This method separates and quantifies benzo[a]pyrene (the most toxic PAHs) and non-priority benzo[e]pyrene (isomers, little toxicity) to avoid overestimation of toxin levels, demonstrating its importance for health-related researches. With 0.5% 2,4-difluoroanisole in chlorobenzene as the dopant, limits of detection of PAHs except acenaphthylene and those of nitro-PAHs except 2-nitrofluoranthene are below 10 pg and 3 pg, respectively, mostly lower than or comparable to those reported using LC-related systems. The responses were linear over two orders of magnitude with fairly good accuracy and precision. Certified reference materials and real aerosol samples were analyzed to demonstrate its applicability. This fast, sensitive, and reliable method is the first UHPLC-APPI-MS/MS method capable of simultaneously analyzing 29 environmentally and toxicologically important PAHs and nitro-PAHs.

  2. Trace analysis of selected hormones and sterols in river sediments by liquid chromatography-atmospheric pressure chemical ionization-tandem mass spectrometry.

    Science.gov (United States)

    Matić, Ivana; Grujić, Svetlana; Jauković, Zorica; Laušević, Mila

    2014-10-17

    In this paper, development and optimization of new LC-MS method for determination of twenty selected hormones, human/animal and plant sterols in river sediments were described. Sediment samples were prepared using ultrasonic extraction and clean up with silica gel/anhydrous sodium sulphate cartridge. Extracts were analyzed by liquid chromatography-linear ion trap-tandem mass spectrometry, with atmospheric pressure chemical ionization. The optimized extraction parameters were extraction solvent (methanol), weight of the sediment (2 g) and time of ultrasonic extraction (3× 10 min). Successful chromatographic separation of hormones (estriol and estrone, 17α- and 17β-estradiol) and four human/animal sterols (epicoprostanol, coprostanol, α-cholestanol and β-cholestanol) that have identical fragmentation reactions was achieved. The developed and optimized method provided high recoveries (73-118%), low limits of detection (0.8-18 ng g(-1)) and quantification (2.5-60 ng g(-1)) with the RSDs generally lower than 20%. Applicability of the developed method was confirmed by analysis of six river sediment samples. A widespread occurrence of human/animal and plant sterols was found. The only detected hormone was mestranol in just one sediment sample. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. A highly specific and sensitive quantification analysis of the sterols in silkworm larvae by high performance liquid chromatography-atmospheric pressure chemical ionization-tandem mass spectrometry.

    Science.gov (United States)

    Igarashi, Fumihiko; Hikiba, Juri; Ogihara, Mari H; Nakaoka, Takayoshi; Suzuki, Minoru; Kataoka, Hiroshi

    2011-12-15

    The biochemical quantification of sterols in insects has been difficult because only small amounts of tissues can be obtained from insect bodies and because sterol metabolites are structurally related. We have developed a highly specific and sensitive quantitative method for determining of the concentrations of seven sterols-7-dehydrocholesterol, desmosterol, cholesterol, ergosterol, campesterol, stigmasterol, and β-sitosterol-using a high performance liquid chromatography-atmospheric pressure chemical ionization-tandem mass spectrometry (HPLC/APCI-MS/MS). The sterols were extracted from silkworm larval tissues using the Bligh and Dyer method and were analyzed using HPLC/APCI-MS/MS with selected reaction monitoring, using cholesterol-3,4-(13)C(2) as an internal standard. The detection limits of the method were between 12.1 and 259 fmol. The major sterol in most silkworm larval tissues was cholesterol, whereas only small quantities of the dietary sterols were detected. Thus, a simple, sensitive, and specific method was successfully developed for the quantification of the sterol concentrations in each tissue of an individual silkworm larva. This method will be a useful tool for investigating to molecular basis of sterol physiology in insects, facilitating the quantification of femtomole quantities of sterols in biological samples. Copyright © 2011 Elsevier Inc. All rights reserved.

  4. Determination of ethylenethiourea (ETU) and propylenethiourea (PTU) in foods by high performance liquid chromatography-atmospheric pressure chemical ionisation-medium-resolution mass spectrometry.

    Science.gov (United States)

    Startin, James R; Hird, Simon J; Sykes, Mark D

    2005-03-01

    A robust and sensitive method for the determination of ethylenethiourea (ETU) and iso-propylenethiourea (i-PTU) in foods is reported. ETU and i-PTU were extracted by blending with dichloromethane (DCM) in the presence of sodium sulphate, sodium carbonate, thiourea and ascorbic acid. 2H4-ETU and n-PTU were used as internal standards. After filtration the DCM was removed by rotary evaporation and the extract re-dissolved in water before analysis by reversed-phase liquid chromatography with detection by atmospheric pressure chemical ionization-mass spectrometry using a double focusing mass spectrometer at a resolution of 5000. Mean recoveries of ETU and i-PTU from fruit-based, cereal-based and meat-based infant foods, potato chips and tinned potatos at 0.01 mg kg(-1) and from pizza and yoghurt at 0.02-0.1 mg kg(-1) were 95% and 97% respectively. Precision, including both repeatability and internal reproducibility, was in the range of 3.1-13.1%.

  5. Fast analysis of 29 polycyclic aromatic hydrocarbons (PAHs) and nitro-PAHs with ultra-high performance liquid chromatography-atmospheric pressure photoionization-tandem mass spectrometry.

    Science.gov (United States)

    Lung, Shih-Chun Candice; Liu, Chun-Hu

    2015-08-12

    Polycyclic aromatic hydrocarbons (PAHs) and nitro-PAHs are ubiquitous in the environment. Some of them are probable carcinogens and some are source markers. This work presents an ultra-high performance liquid chromatography-atmospheric pressure photoionization-tandem mass spectrometry (UHPLC-APPI-MS/MS) method for simultaneous analysis of 20 PAHs and nine nitro-PAHs. These compounds are separated in 15 minutes in the positive mode and 11 minutes in the negative mode, one half of GC/MS analysis time. Two pairs of precursor/product ions are offered, which is essential for confirmation. This method separates and quantifies benzo[a]pyrene (the most toxic PAHs) and non-priority benzo[e]pyrene (isomers, little toxicity) to avoid overestimation of toxin levels, demonstrating its importance for health-related researches. With 0.5% 2,4-difluoroanisole in chlorobenzene as the dopant, limits of detection of PAHs except acenaphthylene and those of nitro-PAHs except 2-nitrofluoranthene are below 10 pg and 3 pg, respectively, mostly lower than or comparable to those reported using LC-related systems. The responses were linear over two orders of magnitude with fairly good accuracy and precision. Certified reference materials and real aerosol samples were analyzed to demonstrate its applicability. This fast, sensitive, and reliable method is the first UHPLC-APPI-MS/MS method capable of simultaneously analyzing 29 environmentally and toxicologically important PAHs and nitro-PAHs.

  6. Identification and quantification of antitumor thioproline and methylthioproline in Korean traditional foods by a liquid chromatography-atmospheric pressure chemical ionization-tandem mass spectrometry.

    Science.gov (United States)

    Kim, Sun Hyo; Kim, Hyun-Ji; Shin, Ho-Sang

    2014-11-01

    A liquid chromatography-atmospheric pressure chemical ionization-tandem mass spectrometric method (LC-APCI-MS/MS) has been developed for the sensitive determination of antitumor thioproline and methylthioproline from fermented foods. Thioproline and methylthioproline were derivatized in one step with ethyl chloroformate at room temperature. These compounds were identified and quantified in various traditional Korean fermented foods by LC-APCI-MS/MS. The concentration range of thioproline of each food was found for doenjang (0.011-0.032mg/kg), gochujang (0.010-0.038mg/kg), and ganjang (0.010-0.038mg/kg). Those of methylthioproline of each food was found for doenjang (0.098-0.632mg/kg), gochujang (0.015-0.112mg/kg), and ganjang (0.023-1.468mg/kg). A prolonged aging time leads to an increase in both the thioproline and methylthioproline contents, suggesting that the storage time plays a key role in the formation of thioproline and methylthioproline in Korean traditional foods. The results here suggest that thioproline and methylthioproline are related to the biological activities of traditional Korean fermented foods.

  7. Determination of oxygen and nitrogen derivatives of polycyclic aromatic hydrocarbons in fractions of asphalt mixtures using liquid chromatography coupled to mass spectrometry with atmospheric pressure chemical ionization.

    Science.gov (United States)

    Nascimento, Paulo Cicero; Gobo, Luciana Assis; Bohrer, Denise; Carvalho, Leandro Machado; Cravo, Margareth Coutinho; Leite, Leni Figueiredo Mathias

    2015-12-01

    Liquid chromatography coupled to mass spectrometry with atmospheric pressure chemical ionization was used for the determination of polycyclic aromatic hydrocarbon derivatives, the oxygenated polycyclic aromatic hydrocarbons and nitrated polycyclic aromatic hydrocarbons, formed in asphalt fractions. Two different methods have been developed for the determination of five oxygenated and seven nitrated polycyclic aromatic hydrocarbons that are characterized by having two or more condensed aromatic rings and present mutagenic and carcinogenic properties. The parameters of the atmospheric pressure chemical ionization interface were optimized to obtain the highest possible sensitivity for all compounds. The detection limits of the methods ranged from 0.1 to 57.3 μg/L for nitrated and from 0.1 to 6.6 μg/L for oxygenated derivatives. The limits of quantification were in the range of 4.6-191 μg/L for nitrated and 0.3-8.9 μg/L for oxygenated derivatives. The methods were validated against a diesel particulate extract standard reference material (National Institute of Standards and Technology SRM 1975), and the obtained concentrations (two nitrated derivatives) agreed with the certified values. The methods were applied in the analysis of asphalt samples after their fractionation into asphaltenes and maltenes, according to American Society for Testing and Material D4124, where the maltenic fraction was further separated into its basic, acidic, and neutral parts following the method of Green. Only two nitrated derivatives were found in the asphalt sample, quinoline and 2-nitrofluorene, with concentrations of 9.26 and 2146 mg/kg, respectively, whereas no oxygenated derivatives were detected.

  8. Two-dimensional liquid chromatography

    DEFF Research Database (Denmark)

    Græsbøll, Rune

    Two-dimensional liquid chromatography has received increasing interest due to the rise in demand for analysis of complex chemical mixtures. Separation of complex mixtures is hard to achieve as a simple consequence of the sheer number of analytes, as these samples might contain hundreds or even...... dimensions. As a consequence of the conclusions made within this thesis, the research group has, for the time being, decided against further development of online LC×LC systems, since it was not deemed ideal for the intended application, the analysis of the polar fraction of oil. Trap-and...

  9. Identification and determination of glycosides in tobacco leaves by liquid chromatography with atmospheric pressure chemical ionization tandem mass spectrometry.

    Science.gov (United States)

    Pang, Tao; Yuan, Zhongyi; Dai, Yongsheng; Wang, Chang; Yang, Jun; Peng, Liming; Xu, Guowang

    2007-02-01

    HPLC-atmospheric pressure chemical ionization MS (HPLC-APCI-MS) was used to screen and identify glycosides in tobacco leaf. MS/MS and MS3 and photodiode array (PDA) detection were also used in the characterization. A total of 12 glycosides were found and four of them were identified based on their abundant [M + H]+ ions, UV spectra, and MS/MS analysis and they are scopolin, rutin, quercetin-3-glycoside, and kaempferol-3-rutinoside. Analytical characteristics of the method were investigated. The contents of these glycosides were obtained and compared based on the relative peak area to the internal standard in seven kinds of tobacco leaf.

  10. Field-Free Atmospheric Pressure Photoionization - Liquid Chromatography - Mass Spectrometry for the Analysis of Steroids within Complex Biological Matrices.

    Science.gov (United States)

    McCulloch, Ross David; Robb, Damon B

    2017-03-06

    A comparison study is presented in which the relative performance of a new orthogonal geometry field-free atmospheric pressure photoionization (FF-APPI) source was evaluated against both electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) for the analysis of a small panel of clinically relevant steroids, spiked within various complex biological matrices. Critical performance factors like sensitivity and susceptibility to matrix effects were assessed using a simple, isocratic, high throughput LC-MS workflow. FF-APPI was found to provide the best performance in terms of both sensitivity and detection limit for all of the steroids included in the survey. Order-of-magnitude sensitivity advantages were realized for some low polarity analytes including both estradiol and estrone. A robust linear regression, post extraction addition method was used to evaluate the relative impact of matrix effects upon each ionization method using protein precipitated human serum, plasma and Surine (simulated urine) as standard clinical matrices. Under conditions optimized for sensitivity, both the field-free APPI and APCI sources were found to provide similarly high resistance to matrix suppression effects, while ESI performance was impacted the most dramatically. For the prototype FF-APPI source, a strong relationship was established between optimizable source parameters and the degree of ion suppression observed. Through careful optimization of vaporization temperature and nebulizer gas flow rates it was possible to significantly reduce or even eliminate the impact of matrix effects, even for high throughput LC-MS methods.

  11. Determination of eight nitrosamines in water at the ng L(-1) levels by liquid chromatography coupled to atmospheric pressure chemical ionization tandem mass spectrometry.

    Science.gov (United States)

    Ripollés, Cristina; Pitarch, Elena; Sancho, Juan V; López, Francisco J; Hernández, Félix

    2011-09-19

    In this work, we have developed a sensitive method for detection and quantification of eight N-nitrosamines, N-nitrosodimethylamine (NDMA), N-nitrosomorpholine (NMor), N-nitrosomethylethylamine (NMEA), N-nitrosopirrolidine (NPyr), N-nitrosodiethylamine (NDEA), N-nitrosopiperidine (NPip), N-nitroso-n-dipropylamine (NDPA) and N-nitrosodi-n-butylamine (NDBA) in drinking water. The method is based on liquid chromatography coupled to tandem mass spectrometry, using atmospheric pressure chemical ionization (APCI) in positive mode with a triple quadrupole analyzer (QqQ). The simultaneous acquisition of two MS/MS transitions in selected reaction monitoring mode (SRM) for each compound, together with the evaluation of their relative intensity, allowed the simultaneous quantification and reliable identification in water at ppt levels. Empirical formula of the product ions selected was confirmed by UHPLC-(Q)TOF MS accurate mass measurements from reference standards. Prior to LC-MS/MS QqQ analysis, a preconcentration step by off-line SPE using coconut charcoal EPA 521 cartridges (by passing 500 mL of water sample) was necessary to improve the sensitivity and to meet regulation requirements. For accurate quantification, two isotope labelled nitrosamines (NDMA-d(6) and NDPA-d(14)) were added as surrogate internal standards to the samples. The optimized method was validated at two concentration levels (10 and 100 ng L(-1)) in drinking water samples, obtaining satisfactory recoveries (between 90 and 120%) and precision (RSDwater samples: chlorinated from drinking water and wastewater treatment plants (DWTP and WWTP, respectively), wastewaters subjected to ozonation and tap waters.

  12. High performance liquid chromatography coupled with atmospheric pressure chemical ionization mass spectrometry for sensitive determination of bioactive amines in donkey milk.

    Science.gov (United States)

    La Torre, Giovanna Loredana; Saitta, Marcello; Giorgia Potortì, Angela; Di Bella, Giuseppa; Dugo, Giacomo

    2010-08-06

    In the present study we report on the optimization and validation of a sensitive high performance liquid chromatography atmospheric pressure chemical ionization mass spectrometry (HPLC-APCI-MS) method for the determination of 8 bioactive amines (histamine, tyramine, tryptamine, 2-phenylethylamine, cadaverine, putrescine, spermidine and spermine) in donkey milk samples. The method involves donkey milk pre-treatment to remove proteins and pre-column dansylation of the amines. HPLC in reversed phase mode has been used for bioactive amines separation and the operating condition of the APCI-MS system proved to be powerful and very efficient for peak assignment. The separation was accomplished in a short time with an excellent resolution for all the amine peaks. Quantification was carried out by monitoring the characteristic [M+H](+) ion of each amine derivative. The method sensitivity, linearity and repeatability were assayed with satisfactory results. The detection limits of the analysed amines ranged from 0.5 microg L(-1) to 15 microg L(-1); the highest LOD was for spermine. Also remarkably good recovery values were obtained; at the lowest spiking level (1 microg L(-1)) the percent mean recoveries ranged from 77.7 to 109.7. Furthermore, as the investigations relate to a complex matrix as donkey milk, suitable studies on matrix effect were performed. Finally, the developed and validated method was applied to analyse 13 donkey milk samples. Among the identified bioactive amines, putrescine, spermine and spermidine proved to be the main amines in donkey milk. Their concentration levels in the present study were lower than the values determined in mature human, cow and sow milk.

  13. Profiling of triacylglycerols in plant oils by high-performance liquid chromatography-atmosphere pressure chemical ionization mass spectrometry using a novel mixed-mode column.

    Science.gov (United States)

    Hu, Na; Wei, Fang; Lv, Xin; Wu, Lin; Dong, Xu-Yan; Chen, Hong

    2014-12-01

    In this investigation, a rapid and high-throughput method for profiling of TAGs in plant oils by liquid chromatography using a single column coupled with atmospheric pressure chemical ionization (APCI) mass spectrometry was reported. A novel mixed-mode phenyl-hexyl chromatographic column was employed in this separation system. The phenyl-hexyl column could provide hydrophobic interactions as well as π-π interactions. Compared with two traditionally columns used in TAG separation - the C18 column and silver-ion column, this column exhibited much higher selectivity for the separation of TAGs with great efficiency and rapid speed. By comparison with a novel mix-mode column (Ag-HiSep OTS column), which can also provide both hydrophobic interactions as well as π-π interactions for the separation of TAGs, phenyl-hexyl column exhibited excellent stability. LC method using phenyl-hexyl column coupled with APCI-MS was successfully applied for the profiling of TAGs in soybean oils, peanut oils, corn oils, and sesame oils. 29 TAGs in peanut oils, 22 TAGs in soybean oils, 19 TAGs in corn oils, and 19 TAGs in sesame oils were determined and quantified. The LC-MS data was analyzed by barcodes and principal component analysis (PCA). The resulting barcodes constitute a simple tool to display differences between different plant oils. Results of PCA also enabled a clear identification of different plant oils. This method provided an efficient and convenient chromatographic technology for the fast characterization and quantification of complex TAGs in plant oils at high selectivity. It has great potential as a routine analytical method for analysis of edible oil quality and authenticity control.

  14. Determination of Glucosamine in Human Plasma by High-Performance Liquid Chromatography-Atmospheric Pressure Chemical Ionization Source-Tandem Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Xingchen Zhou

    2011-01-01

    Full Text Available A sensitive, specific, and rapid high-performance liquid chromatography-atmospheric pressure chemical ionization source-tandem mass spectrometry (HPLC-APCI-MS/MS method for the determination of glucosamine in human plasma was developed and validated. Plasma samples were processed by protein precipitation with dehydrated ethanol, and the chromatographic separation was performed on an Agilent XDB-C18 column with a mobile phase of methanol—0.2% formic acid solution (70 : 30, v/v. Mass spectrometric quantification was carried out in the multiple reaction monitoring (MRM mode, monitoring ion transitions of m/z 180.1 to m/z 162.1 with collision energy (CE of 2 eV for glucosamine and m/z 181.1 to m/z 163.1 with CE of 2 eV for the internal standard (IS in positive ion mode. The linear calibration curves covered a concentration range of 53.27–3409 ng/mL with a lower limit of quantification (LLOQ of 53.27 ng/mL. The extraction recovery of glucosamine was greater than 101.7%. The intra- and interday precisions for glucosamine were less than 10%, and the accuracies were between 93.7% and 102.6%, determined from quality control (QC samples of three representative concentrations. The method has been successfully applied to determining the plasma concentration of glucosamine in a clinical pharmacokinetic study involving 20 healthy Chinese male volunteers.

  15. Liquid phase chromatography on microchips.

    Science.gov (United States)

    Kutter, Jörg P

    2012-01-20

    Over the past twenty years, the field of microfluidics has emerged providing one of the main enabling technologies to realize miniaturized chemical analysis systems, often referred to as micro-Total Analysis Systems (uTAS), or, more generally, Lab-on-a-Chip Systems (LOC) [1,2]. While microfluidics was driven forward a lot from the engineering side, especially with respect to ink jet and dispensing technology, the initial push and interest from the analytical chemistry community was through the desire to develop miniaturized sensors, detectors, and, very early on, separation systems. The initial almost explosive development of, in particular, chromatographic separation systems on microchips, has, however, slowed down in recent years. This review takes a closer, critical look at how liquid phase chromatography has been implemented in miniaturized formats over the past several years, what is important to keep in mind when developing or working with separations in a miniaturized format, and what challenges and pitfalls remain.

  16. Liquid phase chromatography on microchips

    DEFF Research Database (Denmark)

    Kutter, Jörg Peter

    2012-01-01

    Over the past twenty years, the field of microfluidics has emerged providing one of the main enabling technologies to realize miniaturized chemical analysis systems, often referred to as micro-Total Analysis Systems (uTAS), or, more generally, Lab-on-a-Chip Systems (LOC) [1,2]. While microfluidics...... was driven forward a lot from the engineering side, especially with respect to ink jet and dispensing technology, the initial push and interest from the analytical chemistry community was through the desire to develop miniaturized sensors, detectors, and, very early on, separation systems. The initial almost...... explosive development of, in particular, chromatographic separation systems on microchips, has, however, slowed down in recent years. This review takes a closer, critical look at how liquid phase chromatography has been implemented in miniaturized formats over the past several years, what is important...

  17. Mixed Stationary Liquid Phases for Gas-Liquid Chromatography.

    Science.gov (United States)

    Koury, Albert M.; Parcher, Jon F.

    1979-01-01

    Describes a laboratory technique for use in an undergraduate instrumental analysis course that, using the interpretation of window diagrams, prepares a mixed liquid phase column for gas-liquid chromatography. A detailed procedure is provided. (BT)

  18. Liquid chromatography-atmospheric pressure laser ionization-mass spectrometry (LC-APLI-MS) analysis of polycyclic aromatic hydrocarbons with 6-8 rings in the environment.

    Science.gov (United States)

    Thiäner, Jan B; Achten, Christine

    2017-03-01

    A method has been developed for the sensitive and rapid analysis of polycyclic aromatic hydrocarbons (PAHs) in environmental samples using liquid chromatography time-of-flight mass spectrometry as well as the selective atmospheric pressure laser ionization (APLI) process (LC-APLI-MS). Upon analyzing 34 PAHs, the limits of detection of this method were found to range from 0.008 to 1.824 pg (0.024 pg for benzo[a]pyrene). The method therefore provides 30-fold to 5,400-fold increased sensitivity compared with the established GC-MS technique. This LC-APLI-MS method was optimized for higher molecular weight PAHs (C24-C30 PAHs with 6-8 rings), which are difficult to detect or cannot be detected by GC-MS. Using the LC-APLI-MS method, various 6- to 8-ring PAHs were detected in environmental samples for the first time. After developing the method, it was successfully validated in ruggedness tests. The concentrations determined by the LC-APLI-MS method were in good accord with the certified concentrations in three certified reference materials (contaminated soils and sediments). Upon applying the method to environmental samples, it was found that (1) the presence of dibenzo[a,i]pyrene and dibenzo[a,h]pyrene in urban soil samples could only be detected using LC-APLI-MS (i.e., not GC-MS) due to its high sensitivity, (2) a bituminous coal sample yielded 211 tentative peaks from aromatic compounds in the C24-C30 range, and (3) eleven of those compounds occurred in different environmental samples in similar patterns. Hence, 6- to 8-ring PAHs occur in solid environmental samples in which other 6-ring PAHs such as indeno[1,2,3-cd]pyrene or benzo[ghi]perylene may also be present. Some of these numerous higher molecular weight PAH compounds could have very high carcinogenic potential, which will need to be elucidated to ensure the reliability of PAH risk assessments.

  19. Analysis of C60-fullerene derivatives and pristine fullerenes in environmental samples by ultrahigh performance liquid chromatography-atmospheric pressure photoionization-mass spectrometry.

    Science.gov (United States)

    Astefanei, Alina; Núñez, Oscar; Galceran, Maria Teresa

    2014-10-24

    In this work, a method is proposed for the simultaneous analysis of several pristine fullerenes (C60, C70, C76, C78, and C84) and three C60-fullerene derivatives (N-methyl fulleropyrrolidine, [6,6]-phenyl C61 butyric acid methyl ester and [6,6]-phenyl C61 butyric acid butyl ester) in environmental samples. The method involves the use of ultrahigh performance liquid chromatography coupled to atmospheric pressure photoionization mass spectrometry (UHPLC-APPI-MS) and allowed the chromatographic separation in less than 4.5min. The product ions from tandem mass spectrometry studies of fullerene derivatives were characterized and the most abundant one (m/z 720), corresponding to [C60](-), was selected for quantitation. Selected reaction monitoring (SRM at 0.7m/z FWHM) by acquiring two transitions using both isotopic cluster ions [M](-) and [M+1](-) as precursor ions was proposed for quantitation and confirmation purposes. For pristine fullerenes, highly selective selected ion monitoring (H-SIM) acquisition mode by monitoring the isotopic cluster ions [M](-) and [M+1](-) was used. Pressurized solvent extraction conditions were optimized in order to improve recoveries of the studied fullerene compounds from sediment samples. Values up to 87-92% for C60-fullerene derivatives and lower but still acceptable, 70-80%, for pristine fullerenes were obtained. Method limits of quantitation (MLOQs) ranging from 1.5pgL(-1) to 5.5ngL(-1) in water samples and from 0.1ngkg(-1) to 523ngkg(-1) in sediments were obtained with good precision (relative standard deviations always lower than 13%). The applicability of the developed method was evaluated by analyzing several environmental samples such as sediments and pond water and the detected levels for C60-fullerene derivatives were of 0.1-2.7ngkg(-1) and 1.5-8.5pgL(-1), respectively. C60 and C70 were the only pristine fullerenes detected in the analyzed samples (0.1-7.2ngkg(-1) in sediments and 9-330pgL(-1) in water pond samples). Copyright

  20. Online profiling of triacylglycerols in plant oils by two-dimensional liquid chromatography using a single column coupled with atmospheric pressure chemical ionization mass spectrometry.

    Science.gov (United States)

    Wei, Fang; Ji, Shu-Xian; Hu, Na; Lv, Xin; Dong, Xu-Yan; Feng, Yu-Qi; Chen, Hong

    2013-10-18

    The complexity of natural triacylglycerols (TAGs) in various edible oils is high because of the hundreds of TAG compositions, which makes the profiling of TAGs quite difficult. In this investigation, a rapid and high-throughput method for online profiling of TAGs in plant oils by two-dimensional (2D) liquid chromatography using a single column coupled with atmospheric pressure chemical ionization (APCI) mass spectrometry was reported. A novel mixed-mode 2D chromatographic column packed with silver-ion-modified octyl and sulfonic co-bonded silica was employed in this online 2D separation system. This novel 2D column combined the features of C8 column and silver-ion. In comparison with the traditional C18 column and silver-ion column, which are the two main columns used for the separation of complex TAGs in natural oil samples, this novel 2D column, could provide hydrophobic interactions as well as π-complexation interactions. It exhibited much higher selectivity for the separation of TAGs, and the separation was rapid. This online 2D separation system was successful in the separation of a large number of TAG solutes, and the TAG structures were evaluated by analyzing their APCI mass spectra information. This system was applied for the profiling of TAGs in peanut oils, corn oils, and soybean oils. 30 TAGs in peanut oils, 18 TAGs in corn oils, and 21 TAGs in soybean oils were determined and quantified. The highest relative content of TAGs was LLL, which was found in corn oil with the relative content up to 45.43 (%, w/w), and the lowest relative content of TAGs was LLS and OSS, which was found in soybean oil and corn oil respectively, with the relative content only 0.01 (%, w/w). In addition, the TAG data were analyzed by principal component analysis (PCA). Results of PCA enabled a clear identification of different plant oils. This method provided an efficient and convenient chromatographic technology for the fast characterization and quantification of complex TAGs

  1. Determination of eight nitrosamines in water at the ng L{sup -1} levels by liquid chromatography coupled to atmospheric pressure chemical ionization tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Ripolles, Cristina; Pitarch, Elena; Sancho, Juan V.; Lopez, Francisco J. [Research Institute for Pesticides and Water, University Jaume I, Avda. Sos Baynat, E-12071 Castellon (Spain); Hernandez, Felix, E-mail: felix.hernandez@qfa.uji.es [Research Institute for Pesticides and Water, University Jaume I, Avda. Sos Baynat, E-12071 Castellon (Spain)

    2011-09-19

    Highlights: {center_dot} Eight N-nitrosamines in water by LC(APCI)MS/MS QqQ analysis. {center_dot} Validation at two levels: 10 ng L{sup -1} (LOQ) and 100 ng L{sup -1} in drinking water. {center_dot} Developed method applied to different types of water samples. {center_dot} NDMA was the analyte more frequently detected and at the highest concentration levels. - Abstract: In this work, we have developed a sensitive method for detection and quantification of eight N-nitrosamines, N-nitrosodimethylamine (NDMA), N-nitrosomorpholine (NMor), N-nitrosomethylethylamine (NMEA), N-nitrosopirrolidine (NPyr), N-nitrosodiethylamine (NDEA), N-nitrosopiperidine (NPip), N-nitroso-n-dipropylamine (NDPA) and N-nitrosodi-n-butylamine (NDBA) in drinking water. The method is based on liquid chromatography coupled to tandem mass spectrometry, using atmospheric pressure chemical ionization (APCI) in positive mode with a triple quadrupole analyzer (QqQ). The simultaneous acquisition of two MS/MS transitions in selected reaction monitoring mode (SRM) for each compound, together with the evaluation of their relative intensity, allowed the simultaneous quantification and reliable identification in water at ppt levels. Empirical formula of the product ions selected was confirmed by UHPLC-(Q)TOF MS accurate mass measurements from reference standards. Prior to LC-MS/MS QqQ analysis, a preconcentration step by off-line SPE using coconut charcoal EPA 521 cartridges (by passing 500 mL of water sample) was necessary to improve the sensitivity and to meet regulation requirements. For accurate quantification, two isotope labelled nitrosamines (NDMA-d{sub 6} and NDPA-d{sub 14}) were added as surrogate internal standards to the samples. The optimized method was validated at two concentration levels (10 and 100 ng L{sup -1}) in drinking water samples, obtaining satisfactory recoveries (between 90 and 120%) and precision (RSD < 20%). Limits of detection were found to be in the range of 1-8 ng L{sup -1

  2. Quantification of 16 polycyclic aromatic hydrocarbons in cigarette smoke condensate using stable isotope dilution liquid chromatography with atmospheric-pressure photoionization tandem mass spectrometry.

    Science.gov (United States)

    Zhang, Xiaotao; Hou, Hongwei; Chen, Huan; Liu, Yong; Wang, An; Hu, Qingyuan

    2015-09-17

    A stable isotope dilution liquid chromatography with tandem mass spectrometry method for the analysis of 16 polycyclic aromatic hydrocarbons in cigarette smoke condensate was developed and validated. Compared with previously reported methods, this method has lower limits of detection (0.04-1.35 ng/cig). Additionally, the proposed method saves time, reduces the number of separation steps, and reduces the quantity of solvent needed. The new method was applied to evaluate polycyclic aromatic hydrocarbon content in 213 commercially available cigarettes in China, under the International Standardization Organization smoking regime and the Health Canadian intense smoking regime. The results showed that the total polycyclic aromatic hydrocarbon content was more than two times higher in samples from the Health Canadian intense smoking regime than in samples from the International Standardization Organization smoking regime (1189.23 vs. 2859.50 ng/cig, ppolycyclic aromatic hydrocarbons (and total polycyclic aromatic hydrocarbons) increased with labeled tar content in both of the tested smoking regimes. There was a positive correlation between total polycyclic aromatic hydrocarbons under the International Standardization Organization smoking regime with that under the Health Canadian intense smoking regime. The proposed liquid chromatography with tandem mass spectrometry method is satisfactory for the rapid, sensitive, and accurately quantitative evaluation of polycyclic aromatic hydrocarbon content in cigarette smoke condensate, and it can be applied to assess potential health risks from smoking. This article is protected by copyright. All rights reserved.

  3. Low thermal mass liquid chromatography.

    Science.gov (United States)

    Gu, Binghe; Cortes, Hernan; Luong, Jim; Pursch, Matthias; Eckerle, Patric; Mustacich, Robert

    2009-02-15

    A novel technique, low thermal mass liquid chromatography (LTMLC), is introduced in this study. The use of an LTM assembly that utilizes the principle of resistive wire heating and a temperature sensor to accurately deliver unprecedented heating (up to 1800 degrees C/min) or cooling (100 to approximately 200 degrees C/min) rates is reported. With the use of packed microcolumns (heat transfer from the assembly to the mobile phase was obtained. A systematic investigation was conducted to study the performance of the LTMLC technique. Both isocratic and gradient mobile phase conditions were used. For temperature control, isothermal, temperature-increasing, and temperature-decreasing gradients were applied. Three model mixtures, two of which containing neutral and acidic analytes and the other containing neutral, acidic, and basic analytes, were used to study the effect of temperature on elution time, resolution, column efficiency, and selectivity. It was found that the LTMLC experimental setup delivered reliable temperature control, as evidenced by linear van't Hoff plots for neutral and acidic compounds. The effect of temperature on the elution of basic analytes yielded nonlinear van't Hoff plots, explaining the dramatic selectivity changes observed for bases with changes in column temperature. Column efficiency generally increased with the increase in column temperature in the range of 25 to approximately 75 degrees C and decreased in the range of 75 to approximately 150 degrees C at a fixed column flow rate (3 microL/min), when extra column band broadening was taken into account. The increase in efficiency upon the increase in column temperature in the low temperature range was mainly due to the decreased mass transfer term resulting from increased analyte diffusivity. However, under even higher temperatures, the longitudinal diffusion dominated band broadening, explaining the decrease in column efficiency upon a further increase in column temperature. Resolution

  4. Development and Comparison of Three Liquid Chromatography-Atmospheric Pressure Chemical Ionization/Mass Spectrometry Methods for Determining Vitamin D Metabolites in Human Serum

    OpenAIRE

    Bedner, Mary; Karen W. Phinney

    2012-01-01

    Liquid chromatographic methods with atmospheric pressure chemical ionization mass spectrometry were developed for the determination of the vitamin D metabolites 25-hydroxyvitamin D2 (25(OH)D2), 25-hydroxyvitamin D3 (25(OH)D3), and 3-epi-25-hydroxyvitamin-D3 (3-epi-25(OH)D3) in the four Levels of SRM 972, Vitamin D in Human Serum. One method utilized a C18 column, which separates 25(OH)D2 and 25(OH)D3, and one method utilized a CN column that also resolves the diastereomers 25(OH)D3 and 3-epi-...

  5. Identification and quantification of flavonoids in human urine samples by column switching liquid chromatography coupled to atmospheric pressure chemical ionization mass spectrometry

    DEFF Research Database (Denmark)

    Nielsen, Salka E.; Freese, R.; Cornett, C.

    2000-01-01

    A rapid and sensitive high-performance liquid chromatographic mass spectrometric (HPLC-MS) method is described for the determination and quantification of 12 dietary flavonoid glycosides and aglycons in human urine samples. Chromatographic separation of the analytes of interest was achieved...... by column-switching, using the first column (a Zorbax 300SB C-3 column) for sample cleanup and eluting the heart-cut flavonoid fraction onto the second column (a Zorbax SE C-18 column) for separation and detection by ultraviolet and atmospheric pressure chemical ionization MS using single ion monitoring...... with high and low flavonoid content was analyzed, and the results are reported....

  6. Liquid chromatography detection unit, system, and method

    Energy Technology Data Exchange (ETDEWEB)

    Derenzo, Stephen E.; Moses, William W.

    2015-10-27

    An embodiment of a liquid chromatography detection unit includes a fluid channel and a radiation detector. The radiation detector is operable to image a distribution of a radiolabeled compound as the distribution travels along the fluid channel. An embodiment of a liquid chromatography system includes an injector, a separation column, and a radiation detector. The injector is operable to inject a sample that includes a radiolabeled compound into a solvent stream. The position sensitive radiation detector is operable to image a distribution of the radiolabeled compound as the distribution travels along a fluid channel. An embodiment of a method of liquid chromatography includes injecting a sample that comprises radiolabeled compounds into a solvent. The radiolabeled compounds are then separated. A position sensitive radiation detector is employed to image distributions of the radiolabeled compounds as the radiolabeled compounds travel along a fluid channel.

  7. Liquid chromatography detection unit, system, and method

    Science.gov (United States)

    Derenzo, Stephen E.; Moses, William W.

    2015-10-27

    An embodiment of a liquid chromatography detection unit includes a fluid channel and a radiation detector. The radiation detector is operable to image a distribution of a radiolabeled compound as the distribution travels along the fluid channel. An embodiment of a liquid chromatography system includes an injector, a separation column, and a radiation detector. The injector is operable to inject a sample that includes a radiolabeled compound into a solvent stream. The position sensitive radiation detector is operable to image a distribution of the radiolabeled compound as the distribution travels along a fluid channel. An embodiment of a method of liquid chromatography includes injecting a sample that comprises radiolabeled compounds into a solvent. The radiolabeled compounds are then separated. A position sensitive radiation detector is employed to image distributions of the radiolabeled compounds as the radiolabeled compounds travel along a fluid channel.

  8. High-performance liquid chromatography of biopolymers

    Energy Technology Data Exchange (ETDEWEB)

    Regnier, F.E.

    1983-10-21

    The ability to separate biological macromolecules with good resolution on liquid chromatographic columns has depended on the development of suitable packing materials. In size exclusion chromatography, molecules are separated by size on the basis of differential permeation of the packing. Ion exchange, hydrophobic interaction (or reversed-phase), and affinity chromatography are all surface-mediated separation methods, although they depend on different retention mechanisms. High-performance liquid chromatographic columns designed for biopolymers offer major advantages over conventional columns in both speed and resolving power. The exponential growth of literature on the high-performance separation of peptides and proteins in particular indicates that the techniques will become the dominant form of column liquid chromatography. 92 refs., 4 figs.

  9. Quantification of β-carotene, retinol, retinyl acetate and retinyl palmitate in enriched fruit juices using dispersive liquid-liquid microextraction coupled to liquid chromatography with fluorescence detection and atmospheric pressure chemical ionization-mass spectrometry.

    Science.gov (United States)

    Viñas, Pilar; Bravo-Bravo, María; López-García, Ignacio; Hernández-Córdoba, Manuel

    2013-02-01

    A detailed optimization of dispersive liquid-liquid microextraction (DLLME) was carried out for developing liquid chromatographic (HPLC) techniques, using both fluorescence and atmospheric pressure chemical ionization mass spectrometric (APCI-MS) detection, for the simultaneous analysis of preforms of vitamin A: retinol (R), retinyl acetate (RA), retinyl palmitate (RP) and β-carotene (β-C). The HPLC analyses were carried out using a mobile phase composed of methanol and water, with gradient elution. The APCI-MS and fluorescence spectra permitted the correct identification of compounds in the analyzed samples. Parameters affecting DLLME were optimized using 2 mL of methanol (disperser solvent) containing 150 μL carbon tetrachloride (extraction solvent). The precision ranged from 6% to 8% (RSD) and the limits of detection were between 0.03 and 1.4 ng mL(-1), depending on the compound. The enrichment factor values were in the 21-44 range. Juice samples were analyzed without saponification and no matrix effect was found when using fluorescence detection, so calibration was possible with aqueous standards. However, a matrix effect appeared with APCI-MS, in which case it was necessary to apply matrix-matched calibration. There was great variability in the forms of vitamin A present in the juices, the most abundant ester being retinyl acetate (0.04 to 3.4 μg mL(-1)), followed by the amount of retinol (0.01 to 0.16 μg mL(-1)), while retinyl palmitate was not detected, except in the milk-containing juice, in which RP was the main form. The representative carotenoid β-carotene was present in the orange, peach, mango and multifruit juices in high amounts. The method was validated using two certified reference materials.

  10. Systematic screening and characterization of glycosides in tobacco leaves by liquid chromatography with atmospheric pressure chemical ionization tandem mass spectrometry using neutral loss scan and product ion scan.

    Science.gov (United States)

    Ding, Li; Wang, Xiaoyu; Wang, Sheng; Yu, Jingjing; Qin, Yaqiong; Zhang, Xiaobing; Xie, Fuwei

    2015-12-01

    Glycosides in tobacco leaves are highly important aromatic precursors. It is necessary to reveal glycosides in tobacco leaves to improve tobacco planting and processing. This study describes a method for the systematic screening of glycosides in tobacco leaves by liquid chromatography with tandem mass spectrometry. Although glycosides contain numerous aglycones, the number of glycans is limited. Based on a screening table of glycans designed for neutral loss scan, glycosides with different aglycones were systematically screened out. Then, the MS(2) fragment spectra of scanned glycosides were further obtained using product ion scan. By comparison with the spectra in online tandem mass spectral databases, reported references, and verification by commercial standards, 64 glycosides were detected, including 39 glycosides linked with monosaccharides, 18 glycosides linked with disaccharides and 7 glycosides linked with trisaccharides. It is noteworthy that glycosides linked with trisaccharides have previously been rarely reported in tobacco. This method appears to be a useful tool for the systematic screening and characterization of glycosides in tobacco and can potentially be applied to other plants.

  11. Instrument platforms for nano liquid chromatography.

    Science.gov (United States)

    Šesták, Jozef; Moravcová, Dana; Kahle, Vladislav

    2015-11-20

    The history of liquid chromatography started more than a century ago and miniaturization and automation are two leading trends in this field. Nanocolumn liquid chromatography (nano LC) and largely synonymous capillary liquid chromatography (capillary LC) are the most recent results of this process where miniaturization of column dimensions and sorbent particle size play crucial role. Very interesting results achieved in the research of extremely miniaturized LC columns at the end of the last century lacked distinctive raison d'être and only advances in mass spectrometry brought a real breakthrough. Configuration of nano LC-electrospray ionization mass spectrometry (LC-ESI-MS) has become a basic tool in bioanalytical chemistry, especially in proteomics. This review discusses and summarizes past and current trends in the realization of nano liquid chromatography (nano LC) platforms. Special attention is given to the mobile phase delivery under nanoflow rates (isocratic, gradient) and sample injection to the nanocolumn. Available detection techniques applied in nano LC separations are also briefly discussed. We followed up the key themes from the original scientific reports over gradual improvements up to the contemporary commercial solutions.

  12. Liquid chromatography of organophosphorus acids

    NARCIS (Netherlands)

    Verweij, A.; Kientz, C.E.; Berg, J. van den

    1988-01-01

    The applicability of different liquid chromatographic systems such as ion-exchange, ion-exclusion, reversed phase and ion-pair partition was studied for the analysis of a number of simple structurally related organophosphorus acids which lack a chromophoric group. Preliminary experiments based on th

  13. Flow Rates in Liquid Chromatography, Gas Chromatography and Supercritical Fluid Chromatography: A Tool for Optimization

    OpenAIRE

    Joris Meurs

    2016-01-01

    This paper aimed to develop a standalone application for optimizing flow rates in liquid chromatography (LC), gas chromatography (GC) and supercritical fluid chromatography (SFC). To do so, Van Deemter’s equation, Knox’ equation and Golay’s equation were implemented in a MATLAB script and subsequently a graphical user interface (GUI) was created. The application will show the optimal flow rate or linear velocity and the corresponding plate height for the set input parameters. Furthermore, a p...

  14. High Performance Liquid Chromatography Experiments to Undergraduate Laboratories

    Science.gov (United States)

    Kissinger, Peter T.; And Others

    1977-01-01

    Reviews the principles of liquid chromatography with electrochemical detection (LCEC), an analytical technique that incorporates the advantages of both liquids chromatography and electrochemistry. Also suggests laboratory experiments using this technique. (MLH)

  15. High Performance Liquid Chromatography/Video Fluorometry. Part I. Instrumentation.

    Science.gov (United States)

    1981-09-30

    High Performance Liquid Chromatography /Video...PERIOD COVERED High Performance Liquid Chromatography /Video .. / Fluorometry. Part I. Instrumentation. . Interim/ echnicaliepart,. 6. PERFORMING ORG...34Entered SECURITY CLASSIFICATION OF THIS OlAGE (When Data Entered) II1| III I I I I E I II ... .. High Performance Liquid Chromatography

  16. Method development for the determination of 24S-hydroxycholesterol in human plasma without derivatization by high-performance liquid chromatography with tandem mass spectrometry in atmospheric pressure chemical ionization mode.

    Science.gov (United States)

    Sugimoto, Hiroshi; Kakehi, Masaaki; Satomi, Yoshinori; Kamiguchi, Hidenori; Jinno, Fumihiro

    2015-10-01

    We developed a highly sensitive and specific high-performance liquid chromatography with tandem mass spectrometry method with an atmospheric pressure chemical ionization interface to determine 24S-hydroxycholesterol, a major metabolite of cholesterol formed by cytochrome P450 family 46A1, in human plasma without any derivatization step. Phosphate buffered saline including 1% Tween 80 was used as the surrogate matrix for preparation of calibration curves and quality control samples. The saponification process to convert esterified 24S-hydroxycholesterol to free sterols was optimized, followed by liquid-liquid extraction using hexane. Chromatographic separation of 24S-hydroxycholesterol from other isobaric endogenous oxysterols was successfully achieved with gradient mobile phase comprised of 0.1% propionic acid and acetonitrile using L-column2 ODS (2 μm, 2.1 mm id × 150 mm). This assay was capable of determining 24S-hydroxycholesterol in human plasma (200 μL) ranging from 1 to 100 ng/mL with acceptable intra- and inter-day precision and accuracy. The potential risk of in vitro formation of 24S-hydroxycholesterol by oxidation from endogenous cholesterol in human plasma was found to be negligible. The stability of 24S-hydroxycholesterol in relevant solvents and human plasma was confirmed. This method was successfully applied to quantify the plasma concentrations of 24S-hydroxycholesterol in male and female volunteers.

  17. Development of gas chromatography-flame ionization detection system with a single column and liquid nitrogen-free for measuring atmospheric C2-C12 hydrocarbons.

    Science.gov (United States)

    Liu, Chengtang; Mu, Yujing; Zhang, Chenglong; Zhang, Zhibo; Zhang, Yuanyuan; Liu, Junfeng; Sheng, Jiujiang; Quan, Jiannong

    2016-01-04

    A liquid nitrogen-free GC-FID system equipped with a single column has been developed for measuring atmospheric C2-C12 hydrocarbons. The system is consisted of a cooling unit, a sampling unit and a separation unit. The cooling unit is used to meet the temperature needs of the sampling unit and the separation unit. The sampling unit includes a dehydration tube and an enrichment tube. No breakthrough of the hydrocarbons was detected when the temperature of the enrichment tube was kept at -90 °C and sampling volume was 400 mL. The separation unit is a small round oven attached on the cooling column. A single capillary column (OV-1, 30 m × 0.32 mm I.D.) was used to separate the hydrocarbons. An optimal program temperature (-60 ∼ 170 °C) of the oven was achieved to efficiently separate C2-C12 hydrocarbons. There were good linear correlations (R(2)=0.993-0.999) between the signals of the hydrocarbons and the enrichment amount of hydrocarbons, and the relative standard deviation (RSD) was less than 5%, and the method detection limits (MDLs) for the hydrocarbons were in the range of 0.02-0.10 ppbv for sampling volume of 400 mL. Field measurements were also conducted and more than 50 hydrocarbons from C2 to C12 were detected in Beijing city.

  18. Liquid chromatography coupled to different atmospheric pressure ionization sources-quadrupole-time-of-flight mass spectrometry and post-column addition of metal salt solutions as a powerful tool for the metabolic profiling of Fusarium oxysporum.

    Science.gov (United States)

    Cirigliano, Adriana M; Rodriguez, M Alejandra; Gagliano, M Laura; Bertinetti, Brenda V; Godeas, Alicia M; Cabrera, Gabriela M

    2016-03-25

    Fusarium oxysporum L11 is a non-pathogenic soil-borne fungal strain that yielded an extract that showed antifungal activity against phytopathogens. In this study, reversed-phase high-performance liquid chromatography (RP-HPLC) coupled to different atmospheric pressure ionization sources-quadrupole-time-of-flight mass spectrometry (API-QTOF-MS) was applied for the comprehensive profiling of the metabolites from the extract. The employed sources were electrospray (ESI), atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI). Post-column addition of metal solutions of Ca, Cu and Zn(II) was also tested using ESI. A total of 137 compounds were identified or tentatively identified by matching their accurate mass signals, suggested molecular formulae and MS/MS analysis with previously reported data. Some compounds were isolated and identified by NMR. The extract was rich in cyclic peptides like cyclosporins, diketopiperazines and sansalvamides, most of which were new, and are reported here for the first time. The use of post-column addition of metals resulted in a useful strategy for the discrimination of compound classes since specific adducts were observed for the different compound families. This technique also allowed the screening for compounds with metal binding properties. Thus, the applied methodology is a useful choice for the metabolic profiling of extracts and also for the selection of metabolites with potential biological activities related to interactions with metal ions.

  19. Basic prinicipal of high performance liquid chromatography

    OpenAIRE

    Ivanova, Violeta

    2016-01-01

    High-performance liquid chromatography (HPLC) is an analytical technique based on the separation of molecules due to differences in their structure and/or composition. Separation is performed between two phases, mobile and stationary. The molecules in the sample have different affinities and interactions with the stationary support, leading to separation of molecules. Compounds which are longer retained at the stationary phase will elute later, compared to those which are distributed into the...

  20. Determination of 21-hydroxydeflazacort in human plasma by high-performance liquid chromatography/atmospheric pressure chemical ionization tandem mass spectrometry. Application to bioequivalence study.

    Science.gov (United States)

    Ifa, D R; Moraes, M E; Moraes, M O; Santagada, V; Caliendo, G; de Nucci, G

    2000-03-01

    A liquid chromatographic atmospheric pressure chemical ionization tandem mass spectrometric method is described for the determination of 21-hydroxydeflazacort in human plasma using dexamethasone 21-acetate as an internal standard. The procedure requires a single diethyl ether extraction. After evaporation of the solvent under a nitrogen flow, the analytes are reconstituted in the mobile phase, chromatographed on a C18 reversed-phase column and analyzed by mass spectrometry via a heated nebulizer interface where they are detected by multiple reaction monitoring. The method has a chromatographic run time of less than 5 min and a linear calibration curve with a range of 1-400 ng ml(-1) (r>0.999). The between-run precision, based on the relative standard deviation for replicate quality controls, was Comercio, Brazil, as a test formulation, and Calcort from Merrell Lepetit, Brazil, as a reference formulation) in 24 healthy volunteers of both sexes who received a single 30 mg dose of each formulation. The study was conducted using an open, randomized, two-period crossover design with a 7-day washout interval. The 90% confidence interval (CI) of the individual geometric mean ratio for Denacen/Calcort was 89.8-109.5% for area under the curve AUC(0-24 h) and 80.7-98.5% for Cmax. Since both the 90% CI for AUC(0-24 h) and Cmax were included in the 80-125% interval proposed by the US Food and Drug Administration, Denacen was considered bioequivalent to Calcort according to both the rate and extent of absorption.

  1. Non-polar lipids characterization of Quinoa (Chenopodium quinoa) seed by comprehensive two-dimensional gas chromatography with flame ionization/mass spectrometry detection and non-aqueous reversed-phase liquid chromatography with atmospheric pressure chemical ionization mass spectrometry detection.

    Science.gov (United States)

    Fanali, Chiara; Beccaria, Marco; Salivo, Simona; Tranchida, Peter; Tripodo, Giusy; Farnetti, Sara; Dugo, Laura; Dugo, Paola; Mondello, Luigi

    2015-07-08

    A chemical characterization of major lipid components, namely, triacylglycerols, fatty acids and the unsaponifiable fraction, in a Quinoa seed lipids sample is reported. To tackle such a task, non-aqueous reversed-phase high-performance liquid chromatography with mass spectrometry detection was employed. The latter was interfaced with atmospheric pressure chemical ionization for the analysis of triacylglycerols. The main triacylglycerols (>10%) were represented by OLP, OOL and OLL (P = palmitoyl, O = oleoyl, L = linoleoyl); the latter was present in the oil sample at the highest percentage (18.1%). Furthermore, fatty acid methyl esters were evaluated by gas chromatography with flame ionization detection. 89% of the total fatty acids was represented by unsaturated fatty acid methyl esters with the greatest percentage represented by linoleic and oleic acids accounting for approximately 48 and 28%, respectively. An extensive characterization of the unsaponifiable fraction of Quinoa seed lipids was performed for the first time, by using comprehensive two-dimensional gas chromatography with dual mass spectrometry/flame ionization detection. Overall, 66 compounds of the unsaponifiable fraction were tentatively identified, many constituents of which (particularly sterols) were confirmed by using gas chromatography with high-resolution time-of-flight mass spectrometry.

  2. Recent applications of hydrophilic interaction liquid chromatography in pharmaceutical analysis.

    Science.gov (United States)

    Zhang, Qian; Yang, Feng-Qing; Ge, Liya; Hu, Yuan-Jia; Xia, Zhi-Ning

    2017-01-01

    Hydrophilic interaction liquid chromatography, an alternative liquid chromatography mode, is of particular interest in separating hydrophilic and polar ionic compounds. Compared with traditional liquid chromatography techniques, hydrophilic interaction liquid chromatography offers specific advantages mainly including: (1) relatively green and water-soluble mobile phase composition, which enhances the solubility of hydrophilic and polar ionic compounds; (2) no need for ion-pairing reagents and high content of organic solvent, which benefits mass spectrometry detection; (3) high orthogonality to reverse-phase liquid chromatography, well adapted to two-dimensional liquid chromatography for complicated samples. Therefore, hydrophilic interaction liquid chromatography has been rapidly developed in many areas over the past decades. This review summarizes the recent progress (from 2012 to July 2016) of hydrophilic interaction liquid chromatography in pharmaceutical analysis, with the focus on detecting chemical drugs in various matrices, charactering active compounds of natural products and assessing biotherapeutics through typical structure unit. Moreover, the retention mechanism and behavior of analytes in hydrophilic interaction liquid chromatography as well as some novel hydrophilic interaction liquid chromatography columns used for pharmaceutical analysis are also described.

  3. Simultaneous extraction of acetylsalicylic acid and salicylic acid from human plasma and simultaneous estimation by liquid chromatography and atmospheric pressure chemical ionization/tandem mass spectrometry detection. Application to a pharmacokinetic study.

    Science.gov (United States)

    Nirogi, Ramakrishna; Kandikere, Vishwottam; Mudigonda, Koteshwara; Ajjala, Devender; Suraneni, Ramakrishna; Thoddi, Parthasarathi

    2011-01-01

    A simple analytical method using liquid chromatography-tandem mass spectrometry (LC-MS/MS) in atmospheric chemical ionization mode (APCI) for the simultaneous estimation of acetylsalicylic acid (ASA, CAS 50-78-2) and its active metabolite salicylic acid (SA, CAS 69-72-7) in human plasma has been developed and validated. ASA and SA were analyzed simultaneously despite differences in plasma concentration ranges of ASA and SA after oral administration of ASA. In spite of having different chemical, ionization and chromatographic properties, ASA and SA were extracted simultaneously from the plasma sample using acetonitrile protein precipitation followed by liquid-liquid extraction. The analytes were separated on a reversed phase column with rapid gradient program using mobile phase consisting of ammonium acetate buffer and methanol. The structural analogue diclofenac was used as an internal standard. The multiple reaction monitoring (MRM) transitions m/z 179 --> 137 for ASA, m/z 137 --> 65 for SA and m/z 294 --> 250 for IS were used. The assay exhibited a linear dynamic range of 0.02-10 microg/mL for ASA and 0.1-50 microg/mL for SA. The between-batch precision (%CV) ranged from 2.1 to 7.9% for ASA and from 0.2 to 5.2% for SA. The between-batch accuracy ranged from 95.4 to 96.7% for ASA and from 94.6 to 111.3% for SA. The validated method was successfully applied for the evaluation of pharmacokinetics of ASA after single oral administration of 650 mg test formulation versus two 325 mg reference formulations of ASA in human subjects.

  4. High Performance Liquid Chromatography/Video Fluorometry. Part II. Applications.

    Science.gov (United States)

    1981-09-30

    HIGH PERFORMANCE LIQUID CHROMATOGRAPHY /VIDEO FLUOROMETRY. PART...REP«T_N&:-ŗ/ High Performance Liquid Chromatography /Video Fluorometry» Part II. Applications« by | Dennis C./Shelly* Michael P./Vogarty and...Data EnlirtdJ REPORT DOCUMENTATION PAGE t. REPORT NUMBER 2 GOVT ACCESSION NO 4. T1TI.F (and Submit) lP-^fffsyva High Performance Liquid Chromatography

  5. Analytical capabilities of high performance liquid chromatography - Atmospheric pressure photoionization - Orbitrap mass spectrometry (HPLC-APPI-Orbitrap-MS) for the trace determination of novel and emerging flame retardants in fish.

    Science.gov (United States)

    Zacs, D; Bartkevics, V

    2015-10-22

    A new analytical method was established and validated for the analysis of 27 brominated flame retardants (BFRs), including so called "emerging" and "novel" BFRs (EBFRs and NBFRs) in fish samples. High performance liquid chromatography (HPLC) coupled to Orbitrap mass spectrometry (Orbitrap-MS) employing atmospheric pressure photoionization (APPI) interface operated in negative mode was used for the identification/quantitation of contaminants. HPLC-Orbitrap-MS analysis provided a fast separation of selected analytes within 14 min, thus demonstrating a high throughput processing of samples. The developed methodology was tested by intralaboratory validation in terms of recovery, repeatability, linear calibration ranges, instrumental and method limits of quantitation (i-LOQ and m-LOQ), and where possible, trueness was verified by analysis of certified reference materials (CRMs). Recoveries of analytes were between 80 and 119%, while the repeatability in terms of relative standard deviations (RSDs) was in the range from 1.2 to 15.5%. The measured values for both analyzed CRMs agreed with the provided consensus values, revealing the recovery of reference concentrations in 72-119% range. The elaborated method met the sensitivity criterion according to Commission Recommendation 2014/118/EU on monitoring of BFRs in food products for majority of the compounds. The concentrations of polybrominated diphenyl ethers (PBDEs) in real samples determined by HPLC-APPI-Orbitrap-MS method and validated gas chromatography-high-resolution mass spectrometry (GC-HRMS) method were found to be in a good agreement. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Simultaneous determination of hydroxycinnamates and catechins in human urine samples by column switching liquid chromatography coupled to atmospheric pressure chemical ionization mass spectrometry

    DEFF Research Database (Denmark)

    Nielsen, Salka E.; Sandström, B.

    2003-01-01

    by atmospheric pressure chemical ionization (APCI) MS using single ion monitoring (SIM) in negative mode. Linear calibration graphs were achieved in the dynamic range of 10-1000 ng/ml urine. The inter- and intraassay coefficients of variation (C.V.%) for the analysis of the four compounds in quality control...

  7. Analysis of vitamin K-1 in fruits and vegetables using accelerated solvent extraction and liquid chromatography tandem mass spectrometry with atmospheric pressure chemical ionization

    DEFF Research Database (Denmark)

    Jäpelt, Rie Bak; Jakobsen, Jette

    2016-01-01

    spectrometry with atmospheric pressure chemical ionization in selected reaction monitoring mode with deuterium-labeled vitamin K1 as an internal standard. The precision was estimated as the pooled estimate of three replicates performed on three different days for spinach, peas, apples, banana, and beetroot...

  8. Simulating retention in gas-liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Martin, M.G.; Siepmann, J.I.; Schure, M.R.

    1999-12-16

    Accurate predictions of retention times, retention indices, and partition constants are a long sought-after goal for theoretical studies in chromatography. Configurational-bias Monte Carlo (CBMC) simulations in the Gibbs ensemble using the transferable potentials for phase equilibria-united atom (TraPPE-UA) force field have been carried out to obtain a microscopic picture of the partitioning of 10 alkane isomers between a helium vapor phase and a squalane liquid phase, a protypical gas-liquid chromatography system. The alkane solutes include some topological isomers that differ only in the arrangement of their building blocks (e.g., 2,5-dimethylhexane and 3,4-dimethylhexane), for which the prediction of the retention order is particularly difficult. The Kovats retention indices, a measure of the relative retention times, are calculated directly from the partition constants and are in good agreement with experimental values. The calculated Gibbs free energies of transfer for the normal alkanes conform to Martin's equation which is the basis of linear free energy relationships used in many process modeling packages. Analysis of radial distribution functions and the corresponding energy integrals does not yield evidence for specific retention structures and shows that the internal energy of solvation is not the main driving force for the separation of topological isomers in this system.

  9. Characterization and quantification of triacylglycerols in peanut oil by off-line comprehensive two-dimensional liquid chromatography coupled with atmospheric pressure chemical ionization mass spectrometry.

    Science.gov (United States)

    Hu, Jun; Wei, Fang; Dong, Xu-Yan; Lv, Xin; Jiang, Mu-Lan; Li, Guang-Ming; Chen, Hong

    2013-01-01

    The complexity of natural triacylglycerols (TAGs) in various edible oils is prodigious due to the hundreds of set is of TAG compositions, which makes the identification of TAGs quite difficult. In this investigation, the off-line 2D system coupling of nonaqueous RP and silver-ion HPLC with atmospheric pressure chemical ionization MS detection has been applied to the identification and quantification of TAGs in peanut oil. The method was successful in the separation of a high number of TAG solutes, and the TAG structures were evaluated by analyzing their atmospheric pressure chemical ionization mass spectra information. HPLC and MS conditions have been optimized and the fragmentation mechanisms of isomers have been validated. In addition, an internal standard approach has been developed for TAG quantification. Then this system was applied in peanut oil samples and there was a total of 48 TAGs including regioisomers that have been determined and quantified.

  10. Identification and quantification of flavonoids in human urine samples by column switching liquid chromatography coupled to atmospheric pressure chemical ionization mass spectrometry

    DEFF Research Database (Denmark)

    Nielsen, S. E.; Freese, R.; Cornett, Claus

    2000-01-01

    by column-switching, using the first column (a Zorbax 300SB C-3 column) for sample cleanup and eluting the heart-cut flavonoid fraction onto the second column (a Zorbax SE C-18 column) for separation and detection by ultraviolet and atmospheric pressure chemical ionization MS using single ion monitoring...... of variation for the analysis of the 12 different flavonoids in quality control urine samples were 12.3% on average (range 11.0-13.7%, n = 24, reproducibility) and the repeatability of the assay were 5.0% (mean, range 0.1-14.8%, it = 12). A subset of 10 urine samples from a human dietary intervention study...

  11. Two-step cleanup procedure for the identification of carotenoid esters by liquid chromatography-atmospheric pressure chemical ionization-tandem mass spectrometry.

    Science.gov (United States)

    Rodrigues, Daniele Bobrowski; Mariutti, Lilian Regina Barros; Mercadante, Adriana Zerlotti

    2016-07-29

    Carotenoids are naturally found in both free form and esterified with fatty acids in most fruits; however, up to now the great majority of studies only evaluated their composition after saponification. This fact is easily explained by the difficult to analyze carotenoid esters. Preliminary studies showed that cleanup procedures in the extract are necessary for further analysis by LC-MS/MS since triacylglycerols (TAGs) impair the MS detection. Considering these facts, we developed a new cleanup procedure to remove TAGs and other lipids from carotenoid fruit extracts. This procedure is based on physical removal of solid lipids at low temperature followed by open column chromatography on MgO and diatomaceous earth. Before cleanup, four carotenoid diesters and two free xanthophylls were identified in murici (Byrsonyma crassifolia), corresponding to about 65% of the total chromatogram area. After carrying out the two-step cleanup procedure, 35 carotenoids were identified, being 14 monoesters, six free carotenoids and 15 carotenoid diesters. We can conclude that this two-step procedure was successfully applied to murici, an Amazonian fruit, which contains high amounts of lipids.

  12. Comprehensive two-dimensional liquid chromatography: Ion chromatography × reversed-phase liquid chromatography for separation of low-molar-mass organic acids

    NARCIS (Netherlands)

    S.S. Brudin; R.A. Shellie; P.R. Haddad; P.J. Schoenmakers

    2010-01-01

    In the work presented here a novel approach to comprehensive two-dimensional liquid chromatography is evaluated. Ion chromatography is chosen for the first-dimension separation and reversed-phase liquid chromatography is chosen for the second-dimension separation mode. The coupling of these modes is

  13. Detection of flunixin in equine urine using high-performance liquid chromatography with particle beam and atmospheric pressure ionization mass spectrometry after solid-phase extraction.

    Science.gov (United States)

    Stanley, S M; Owens, N A; Rodgers, J P

    1995-05-05

    A normal-phase HPLC method combined with particle-beam mass spectrometry (PB-MS) was developed for the analysis of non-steroidal anti-inflammatory drugs (NSAIDs). The forty one NSAIDs analysed responded in one or more (electron impact, positive and negative chemical ionisation) modes and highly characteristic spectra were produced. A mixed-mode solid-phase extraction (SPE) method for isolating acidic NSAIDs was developed using the Bond Elut Certify II cartridge. The average recovery was 88.5%. Flunixin, extracted by SPE from urine of a mare to which the meglumine salt had been administered was positively identified by HPLC-PB-MS and HPLC-atmospheric pressure ionization (API) MS methods.

  14. Identification of acylated xanthone glycosides by liquid chromatography-atmospheric pressure chemical ionization mass spectrometry in positive and negative modes from the lichen Umbilicaria proboscidea.

    Science.gov (United States)

    Rezanka, Tomás; Dembitsky, Valery M

    2003-05-01

    The xanthoside composition of the crude extract of Umbilicaria proboscidea (L.) Schrader was characterized using LC-UV diode array detection and LC-atmospheric pressure chemical ionization (APCI) MS methods. The presence of acylated xanthone-O-glucosides was determined by both positive and negative ion LC-APCI-MS methods. Based on UV and MS spectral data and NMR spectroscopy, a total of 14 compounds (6-O-acylated umbilicaxanthosides A and B) were identified in U. proboscidea for the first time. In order to further develop the applicability of LC-MS techniques in phytochemical characterization, the effect of different ionization energy on fragmentation was studied using APCI. The optimal ionization conditions were achieved in positive ion APCI by using ammonium acetate buffer and in negative ion APCI by using formic acid (pH 4).

  15. Simultaneous determination of diosmin and diosmetin in human plasma by ion trap liquid chromatography-atmospheric pressure chemical ionization tandem mass spectrometry: Application to a clinical pharmacokinetic study.

    Science.gov (United States)

    Campanero, Miguel Angel; Escolar, Manuel; Perez, Guiomar; Garcia-Quetglas, Emilio; Sadaba, Belen; Azanza, Jose Ramon

    2010-03-11

    Diosmetin (3',5,7-trihydroxy-4'-methoxyflavone) is the aglycone of the flavonoid glycoside diosmin (3',5,7-trihydroxy-4'-methoxyflavone-7-ramnoglucoside). Diosmin is hydrolyzed by enzymes of intestinal micro flora before absorption of its aglycone diosmetin. A specific, sensitive, precise, accurate and robust HPLC assay for the simultaneous determination of diosmin and diosmetin in human plasma was developed and validated. Plasma samples were incubated with beta-glucuronidase/sulphatase. The analytes were isolated by liquid-liquid extraction with tert-butyl methyl ether at pH 2, and separated on a C(18) reversed-phase column using a mixture of methanol/1% formic acid (58:42, v/v) at a flow rate of 0.5ml/min. APCI in the positive ion mode and multiple reaction monitoring (MRM) method was employed. The selected transitions for diosmin, diosmetin and the internal standard (7-ethoxycoumarin) at m/z were: 609.0-->463.0, 301.2-->286.1 and 191, respectively. A good linearity was found in the range of 0.25-500ng/ml (R(2)>0.992) for both compounds. The intra-batch assay precision (CV) for diosmin and diosmetin ranged from 1.5% to 11.2% and from 2.8% to 12.5%, respectively, and the inter-batch precision were from 5.2% to 11.5% and 8.5% to 9.8%, respectively. The accuracy was well within the acceptable range the accuracies (from -2.7% to 4.2% and -1.6% to 3.5% for diosmin and diosmetin, respectively). The mean recoveries of diosmin, diosmetin and the internal standard were 87.5%, 89.2% and 67.2%. Stability studies showed that diosmin and diosmetin were stable in different conditions. Finally, the method was successfully applied to the pharmacokinetic study of diosmin in healthy volunteers following a single oral administration (Daflon).

  16. Characterization of triacylglycerol and diacylglycerol composition of plant oils using high-performance liquid chromatography-atmospheric pressure chemical ionization mass spectrometry.

    Science.gov (United States)

    Holcapek, Michal; Jandera, Pavel; Zderadicka, Petr; Hrubá, Lucie

    2003-08-29

    Triacylglycerols (TGs) and diacylglycerols (DGs) in 16 plant oil samples (hazelnut, pistachio, poppy-seed, almond, palm, Brazil-nut, rapeseed, macadamia, soyabean, sunflower, linseed, Dracocephalum moldavica, evening primrose, corn, amaranth, Silybum arianum) were analyzed by HPLC-MS with atmospheric pressure chemical ionization (APCI) and UV detection at 205 nm on two Nova-Pak C18 chromatographic columns connected in series. A single chromatographic column and non-aqueous ethanol-acetonitrile gradient system was used as a compromise between the analysis time and the resolution for the characterization of TG composition of five plant oils. APCI mass spectra were applied for the identification of all TGs and other acylglycerols. The isobaric positional isomers can be distinguished on the basis of different relative abundances of the fragment ions formed by preferred losses of the fatty acid from sn-1(3) positions compared to the sn-2 position. Excellent chromatographic resolution and broad retention window together with APCI mass spectra enabled positive identification of TGs containing fatty acids with odd numbers of carbon atoms such as margaric (C17:0) and heptadecanoic (C17:1) acids. The general fragmentation patterns of TGs in both APCI and electrospray ionization mass spectra were proposed on the basis of MSn spectra measured with an ion trap analyzer. The relative concentrations of particular TGs in the analyzed plant oils were estimated on the basis of relative peak areas measured with UV detection at 205 nm.

  17. Application of pentafluorophenyl hydrazine derivatives to the analysis of nabumetone and testosterone in human plasma by liquid chromatography-atmospheric pressure chemical ionization-tandem mass spectrometry.

    Science.gov (United States)

    Sheen, J F; Her, G R

    2004-12-01

    Two carbonyl compounds, nabumetone and testosterone, were derivatized with pentafluorophenyl hydrazine (PFPH) and analyzed by atmospheric-pressure chemical-ionization mass spectrometry. The PFPH derivatives underwent dissociative electron capture in negative-ion APCI (ECAPCI) and gave intense [M-20](-) ions in the mass spectra. In positive-ion APCI, the PFPH derivatives underwent efficient protonation and gave intense [M + H](+) ions in the mass spectra. In CID, the major product ions of the [M-20](-) ions in ECAPCI corresponded to the partial moiety of PFPH. In contrast, the major product ions of [M + H](+) corresponded to the partial moiety of the analyte. By using selected reaction monitoring (SRM) detection, low pg of nabumetone (1 pg) and testosterone (7 pg) could be detected in both ECAPCI and positive-ion APCI. In comparison with the detection limits (SRM) of the underivatized analytes, use of the PFPH derivatives resulted in 2500-fold and 35-fold sensitivity enhancements for nabumetone and testosterone, respectively. The PFPH derivatives were applied to the analysis of nabumetone and testosterone in human plasma by both ECAPCI and positive-ion APCI and were found to enable detection of 0.1 ng mL(-1) nabumetone in spiked plasma. For testosterone, endogenous testosterone in female plasma was detected in both ECAPCI and positive-ion APCI.

  18. Comparison of electrospray ionization and atmospheric pressure photoionization liquid chromatography mass spectrometry methods for analysis of ergot alkaloids from endophyte-infected sleepygrass (Achnatherum robustum).

    Science.gov (United States)

    Jarmusch, Alan K; Musso, Ashleigh M; Shymanovich, Tatsiana; Jarmusch, Scott A; Weavil, Miranda J; Lovin, Mary E; Ehrmann, Brandie M; Saari, Susanna; Nichols, David E; Faeth, Stanley H; Cech, Nadja B

    2016-01-05

    Ergot alkaloids are mycotoxins with an array of biological effects. With this study, we investigated for the first time the application of atmospheric pressure photoionization (APPI) as an ionization method for LC-MS analysis of ergot alkaloids, and compared its performance to that of the more established technique of electrospray ionization (ESI). Samples of the grass Achnatherum robustum infected with the ergot producing Epichloë fungus were extracted using cold methanol and subjected to reserved-phase HPLC-ESI-MS and HPLC-APPI-MS analysis. The ergot alkaloids ergonovine and lysergic acid amide were detected in these samples, and quantified via external calibration. Validation parameters were recorded in accordance with ICH guidelines. A triple quadrupole MS operated in multiple reaction monitoring yielded the lowest detection limits. The performance of APPI and ESI methods was comparable. Both methods were subject to very little matrix interference, with percent recoveries ranging from 82% to 100%. As determined with HPLC-APPI-MS quantification, lysergic acid amide and ergonovine were extracted from an A. robustum sample infected with the Epichloë fungus at concentrations of 1.143±0.051 ppm and 0.2822±0.0071 ppm, respectively. There was no statistically significant difference between these concentrations and those determined using ESI for the same samples.

  19. Search for Non-Volatile Components with Low Polarity Characterizing Tobacco Leaves Using Liquid Chromatography / Atmospheric Pressure Chemical Ionization Mass Spectrometry Detector

    Directory of Open Access Journals (Sweden)

    Ishida Naoyuki

    2015-06-01

    Full Text Available Alors que les regards se sont principalement tournés sur les composants à faible polarité dans la résine de feuilles de tabac en raison de leur lien probable avec le goût et l’arôme des produits du tabac, l’absence d’une méthode praticable et d’un outil analytique a longtemps fait obstacle à l’identification des composants non-volatils à faible polarité. L’auteur a, en l’occurrence, porté son attention sur l’analyse recourant à la chromatographie en phase inverse non aqueuse couplée à un détecteur à barrettes de photodiodes et à un détecteur de spectrométrie de masse par ionisation chimique à pression atmosphérique. Cette analyse fut considérée applicable à la séparation des composants nonvolatils significatifs mais inconnus. Son application a permis, avec succès, de séparer, détecter et quantifier simultanément plus de 100 composants non-volatils présentant des polarités faibles et différenciées. Ces composantes furent, entre autres, des solanésols, des triacylglycérides, des phytostérols et des chlorophylles. Cependant, les données concernant les différences de composition parmi les diverses feuilles de tabac demeurent encore partielles et basées sur une analyse ciblée plutôt que globales et basées sur une analyse exhaustive. Aucune étude n’a été, à ce jour, accomplie qui recense les composants essentiels permettant de distinguer, parmi les feuilles de tabac, les différents goûts, arômes, variétés, cultivars, processus de séchage et régions de culture. Par conséquent, toutes les données de quantification ont été consolidées dans le but de former une matrice multidimensionnelle complète et ont subi un traitement statistique qui a mis en exergue les catégories et les composants-clés des diverses feuilles de tabac grâce à une analyse en composantes principales et une classification hiérarchique. Les feuilles de tabac ont, dans un premier temps, été ventilées en

  20. Determination of cholesterol oxides in processed food using high-performance liquid chromatography-mass spectrometry with atmospheric pressure chemical ionisation.

    Science.gov (United States)

    Razzazi-Fazeli, E; Kleineisen, S; Luf, W

    2000-10-27

    The present work describes the development and application of an on-line atmospheric pressure ionisation (APCI) LC-MS interface for the simultaneous determination of seven toxicologically relevant cholesterol oxides (7alpha-hydroxycholesterol, 7beta-hydroxycholesterol, 25-hydroxycholesterol, 7-ketocholesterol, 5,6alpha-, 5,6beta-epoxycholesterol and cholestan-3beta,5alpha,6beta-triol). The HPLC method has been optimised to reach better separation of all tested compounds. The influences of APCI parameters (nebulising temperature, cone voltage, source temperature) on signal intensity and fragmentation pattern were investigated for all tested cholesterol oxides compounds. This is the first report on optimisation and determination of two compounds 7alpha-hydroxycholesterol and 5,6beta-epoxycholesterol in processed food using LC-MS. After extraction with hexane, clean-up was carried out using solid-phase extraction on a silica column. For the chromatographic separation of cholesterol oxides an Aquasil C18 column was used with acetonitrile-methanol (60:40) as mobile phase. For the first time we report the use of such a C18 column with a relatively hydrophilic nature for the separation of cholesterol oxides. APCI-MS detection was then applied in selected ion monitoring and positive ion modes by using the molecular ions and the main fragments. The developed method shows good linearity, high repeatability and good recovery for all tested cholesterol oxides. The method was applied for determination of seven selected cholesterol oxidation products in different foodstuffs such as butter, butteroil, lard and egg powder.

  1. Ion suppression and enhancement effects of co-eluting analytes in multi-analyte approaches: systematic investigation using ultra-high-performance liquid chromatography/mass spectrometry with atmospheric-pressure chemical ionization or electrospray ionization.

    Science.gov (United States)

    Remane, Daniela; Meyer, Markus R; Wissenbach, Dirk K; Maurer, Hans H

    2010-11-15

    In multi-analyte procedures, sufficient separation is important to avoid interferences, particularly when using liquid chromatography/mass spectrometry (LC/MS) because of possible ion suppression or enhancement. However, even using ultra-high-performance LC, baseline separation is not always possible. For development and validation of an LC/MS/MS approach for quantification of 140 antidepressants, benzodiazepines, neuroleptics, beta-blockers, oral antidiabetics, and analytes measured in the context of brain death diagnosis in plasma, the extent of ion suppression or enhancement of co-eluting analytes within and between the drug classes was investigated using atmospheric-pressure chemical ionization (APCI) or electrospray ionization (ESI). Within the drug classes, five analytes showed ion enhancement of over 25% and six analytes ion suppression of over 25% using APCI and 16 analytes ion suppression of over 25% using ESI. Between the drug classes, two analytes showed ion suppression of over 25% using APCI. Using ESI, one analyte showed ion enhancement of over 25% and five analytes ion suppression of over 25%. These effects may influence the drug quantification using calibrators made in presence of overlapping and thus interfering analytes. Ion suppression/enhancement effects induced by co-eluting drugs of different classes present in the patient sample may also lead to false measurements using class-specific calibrators made in absence of overlapping and thus interfering analytes. In conclusion, ion suppression and enhancement tests are essential during method development and validation in LC/MS/MS multi-analyte procedures, with special regards to co-eluting analytes.

  2. An improved high performance liquid chromatography-photodiode array detection-atmospheric pressure chemical ionization-mass spectrometry method for determination of chlorophylls and their derivatives in freeze-dried and hot-air-dried Rhinacanthus nasutus (L.) Kurz.

    Science.gov (United States)

    Kao, Tsai Hua; Chen, Chia Ju; Chen, Bing Huei

    2011-10-30

    Rhinacanthus nasutus (L.) Kurz, a traditional Chinese herb possessing antioxidant and anti-cancer activities, has been reported to contain functional components like carotenoids and chlorophylls. However, the variety and amount of chlorophylls remain uncertain. The objectives of this study were to develop a high performance liquid chromatography-photodiode array detection-atmospheric pressure chemical ionization-mass spectrometry (HPLC-DAD-APCI-MS) method for determination of chlorophylls and their derivatives in hot-air-dried and freeze-dried R. nasutus. An Agilent Eclipse XDB-C18 column and a gradient mobile phase composed of methanol/N,N-dimethylformamide (97:3, v/v), acetonitrile and acetone were employed to separate internal standard zinc-phthalocyanine plus 12 cholorophylls and their derivatives within 21 min, including chlorophyll a, chlorophyll a', hydroxychlorophyll a, 15-OH-lactone chlorophyll a, chlorophyll b, chlorophyll b', hydroxychlorophyll b, pheophytin a, pheophytin a', hydroxypheophytin a, hydroxypheophytin a' and pheophytin b in hot-air-dried R. nasutus with flow rate at 1 mL/min and detection at 660 nm. But, in freeze-dried R. nasutus, only 4 chlorophylls and their derivatives, including chlorophyll a, chlorophyll a', chlorophyll b and pheophytin a were detected. Zinc-phthalocyanine was found to be an appropriate internal standard to quantify all the chlorophyll compounds. After quantification by HPLC-DAD, both chlorophyll a and pheophytin a were the most abundant in hot-air-dried R. nasutus, while in freeze-dried R. nasutus, chlorophyll a and chlorophyll b dominated.

  3. Diclofenac in municipal wastewater treatment plant: quantification using laser diode thermal desorption--atmospheric pressure chemical ionization--tandem mass spectrometry approach in comparison with an established liquid chromatography-electrospray ionization-tandem mass spectrometry method.

    Science.gov (United States)

    Lonappan, Linson; Pulicharla, Rama; Rouissi, Tarek; Brar, Satinder K; Verma, Mausam; Surampalli, Rao Y; Valero, José R

    2016-02-12

    Diclofenac (DCF), a prevalent non-steroidal anti-inflammatory drug (NSAID) is often detected in wastewater and surface water. Analysis of the pharmaceuticals in complex matrices is often laden with challenges. In this study a reliable, rapid and sensitive method based on laser diode thermal desorption/atmospheric pressure chemical ionization (LDTD/APCI) coupled with tandem mass spectrometry (MS/MS) has been developed for the quantification of DCF in wastewater and wastewater sludge. An established conventional LC-ESI-MS/MS (liquid chromatography-electrospray ionization-tandem mass spectrometry) method was compared with LDTD-APCI-MS/MS approach. The newly developed LDTD-APCI-MS/MS method reduced the analysis time to 12s in lieu of 12 min for LC-ESI-MS/MS method. The method detection limits for LDTD-APCI-MS/MS method were found to be 270 ng L(-1) (LOD) and 1000 ng L(-1) (LOQ). Furthermore, two extraction procedures, ultrasonic assisted extraction (USE) and accelerated solvent extraction (ASE) for the extraction of DCF from wastewater sludge were compared and ASE with 95.6 ± 7% recovery was effective over USE with 86 ± 4% recovery. The fate and partitioning of DCF in wastewater (WW) and wastewater sludge (WWS) in wastewater treatment plant was also monitored at various stages of treatment in Quebec Urban community wastewater treatment plant. DCF exhibited affinity towards WW than WWS with a presence about 60% of DCF in WW in contrary with theoretical prediction (LogKow=4.51).

  4. Trends in High Performance Liquid Chromatography for Cultural Heritage.

    Science.gov (United States)

    Degano, Ilaria; La Nasa, Jacopo

    2016-04-01

    The separation, detection and quantitation of specific species contained in a sample in the field of Cultural Heritage requires selective, sensitive and reliable methods. Procedures based on liquid chromatography fulfil these requirements and offer a wide range of applicability in terms of analyte types and concentration range. The main applications of High Performance Liquid Chromatography in this field are related to the separation and detection of dyestuffs in archaeological materials and paint samples by reversed-phase liquid chromatography with suitable detectors. The relevant literature will be revised, with particular attention to sample treatment strategies and future developments. Reversed phase chromatography has also recently gained increasing importance in the analysis of lipid binders and lipid materials in archaeological residues: the main advantages and disadvantages of the new approaches will be discussed. Finally, the main applications of ion chromatography and size exclusion chromatography in the field of Cultural Heritage will be revised in this chapter.

  5. Comparison of high performance liquid chromatography and enzymatic analysis of soluble carbohydrates in loblolly pine

    Science.gov (United States)

    Patricia L. Faulkner; Michele M. Schoeneberger; Kim H. Ludovici

    1993-01-01

    Foliar tissue was collected from a field study designed to test impacts of atmospheric pollutants on loblolIy pine (Pinus taeda L.) seedlings. Standard enzymatic (ENZ) and high performance liquid chromatography (HPLC) methods were used to analyze the tissue for soluble sugars. A comparison of the methods revealed no significant diffennces in accuracy...

  6. Comparison of electrospray ionization and atmospheric pressure chemical ionization for multi-residue analysis of biocides, UV-filters and benzothiazoles in aqueous matrices and activated sludge by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Wick, Arne; Fink, Guido; Ternes, Thomas A

    2010-04-02

    This paper describes the development of a multi-residue method for the determination of 36 emerging organic pollutants (26 biocides, 5 UV-filters and 5 benzothiazoles) in raw and treated wastewater, activated sludge and surface water using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The target analytes were enriched from water samples adjusted to pH 6 by solid-phase extraction (SPE) on Oasis HLB 200mg cartridges and eluted with a mixture of methanol and acetone (60/40, v/v). Extraction of freeze-dried sludge samples was accomplished by pressurized liquid extraction (PLE) using a mixture of methanol and water (50/50, v/v) as extraction solvent followed by SPE. LC-tandem MS detection was compared using electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) in positive and negative ionization mode. ESI exhibited strong ion suppression for most target analytes, while APCI was generally less susceptible to ion suppression but partially leading to ion enhancement of up to a factor of 10. In general, matrix effects could be compensated using stable isotope-labeled surrogate standards, indicated by relative recoveries ranging from 70% to 130%. In wastewater, activated sludge and surface water up to 33 analytes were detected. Maximum concentrations up to 5.1 and 3.9mugL(-1) were found in raw wastewater for the water-soluble UV-filters benzophenone-4 (BZP-4) and phenylbenz-imidazole sulfonic acid (PBSA), respectively. For the first time, the anti-dandruff climbazole was detected in raw wastewater and in activated sludge with concentrations as high as 1.4 microg L(-1) and 1.2 microg gTSS(-1), respectively. Activated sludge is obviously a sink for four benzothiazoles and two isothiazolones, as concentrations were detected in activated sludge between 120 ng gTSS(-1) (2-n-octyl-4-isothiazolin-3-one, OIT) to 330 ng gTSS(-1) (benzothiazole-2-sulfonic acid, BTSA). Copyright (c) 2010 Elsevier B.V. All rights reserved.

  7. High Performance Liquid Chromatography of Vitamin A: A Quantitative Determination.

    Science.gov (United States)

    Bohman, Ove; And Others

    1982-01-01

    Experimental procedures are provided for the quantitative determination of Vitamin A (retinol) in food products by analytical liquid chromatography. Standard addition and calibration curve extraction methods are outlined. (SK)

  8. A generalized theory of chromatography and multistep liquid extraction

    Science.gov (United States)

    Chizhkov, V. P.; Boitsov, V. N.

    2017-03-01

    A generalized theory of chromatography and multistep liquid extraction is developed. The principles of highly efficient processes for fine preparative separation of binary mixture components on a fixed sorbent layer are discussed.

  9. ANALYSIS OF AMINO ACIDS BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

    Directory of Open Access Journals (Sweden)

    Qurat E Noor Baig

    2016-06-01

    Full Text Available Amino acids are the building blocks of proteins and are considered as the key precursors for the formation of hormones and low molecular weight nitrogenous substances with biological importance. Since the analysis of amino acids has been carried out for both qualitative and quantitative purposes with an aim to study their levels in the plasma concentration, the quantitative determination, in particular, also helps in the diagnosis of different diseases associated with their deficiency. This review article deals with the determination of amino acids by chromatographic methods which include ion-exchange chromatography (IEC, high performance liquid chromatography (HPLC, reverse phase-high performance liquid chromatography (RP-HPLC and ultra-performance liquid chromatography (UPLC. The review will also give an idea for the preparation of samples, derivatization methods for the analysis of amino acids (direct and indirect methods and separation of amino acids by high performance liquid chromatographic technique.

  10. Instrumentation for hand-portable liquid chromatography.

    Science.gov (United States)

    Sharma, Sonika; Plistil, Alex; Simpson, Robert S; Liu, Kun; Farnsworth, Paul B; Stearns, Stanley D; Lee, Milton L

    2014-01-31

    Liquid chromatography (LC) has lagged behind gas chromatography (GC) in developments related to hand-portable instrumentation. In this work, a new battery-operated (24V DC) nano-flow pumping system with a stop-flow injector was developed and integrated with an on-column UV-absorption detector (254nm) that was reduced in size to an acceptable weight and power usage for field operation. The pumping system, which includes nano-flow pump, stepper motor and high-pressure valve weighs only 1.372kg (3lbs) and can generate up to 110.32MPa (16,000psi) pressure. A major advantage of this pump is that it does not employ a splitter, since it was specifically designed for capillary column use. The volume capacity of the pump is 24μL, and a sample volume as low as 10nL can be injected. Flow rate calibration (300nL to 6.12μL per min) was performed, and an accuracy >99.94% was obtained. The percent injection carry-over was found to be low (RSD 0.31%), which makes it practical for quantitative analysis. The detector linear range and limit of detection (LOD) were determined using sodium anthraquinone-2-sulfonate. A linear regression coefficient (R) of 0.9996 was obtained for a plot of log peak area versus log concentration over the range of 3.2μM to 6.5mM, and the LOD (S/N=3) was found to be 7.8fmol (0.13μM). The short term noise of the detector is comparable to commercially available detectors (∼10(-5)AU). In this work, the system was tested in the laboratory using regular line power (120V AC) with an AC to DC adapter. Reversed-phase isocratic separations were performed using a 15.5cm×75μm i.d. fused silica capillary column containing a monolithic stationary phase synthesized from 1,6-hexanediol dimethacrylate. Good retention time repeatability (RSD 0.09-0.74%) was obtained for a mixture containing an unretained marker (i.e., uracil) and a homologous series of alkyl benzenes.

  11. Analysis of Tocopherols by High Performance Liquid Chromatography

    OpenAIRE

    Edison, B.

    2009-01-01

    : Gas chromatography is the key technique for organic components and also for tocopherols analysis. High performance liquid chromatography has an important role to take part in applications such as the handling of less usual samples, prevention of degradation of heat sensitive functional groups and for micro preparative purposes. Many approaches for development of improved methods are suggested, especially for reversed phase applications.

  12. Micellar liquid chromatography of terephthalic acid impurities.

    Science.gov (United States)

    Richardson, Ashley E; McPherson, Shakeela D; Fasciano, Jennifer M; Pauls, Richard E; Danielson, Neil D

    2017-03-31

    The production of terephthalic acid (TPA) by oxidation of p-xylene is an important industrial process because high purity TPA is required for the synthesis of polyethylene terephthalate, the primary polymer used to make plastic beverage bottles. Few separation methods have been published that aim to separate TPA from eight major aromatic acid impurities. This work describes a "green" micellar liquid chromatography (MLC) method using a C18 column (100×2.1mm, 3.5μm), an acidic 1% sodium dodecyl sulfate (SDS) mobile phase, and a simple step flow rate gradient to separate TPA and eight impurities in less than 20min. The resulting chromatogram shows excellent peak shape and baseline resolution of all nine acids, in which there are two sets of isomers. Partition coefficients and equilibrium constants have been calculated for the two sets of isomers by plotting the reciprocal of the retention factor versus micelle concentration. Quantitation of the nine analytes in an actual industrial TPA sample is possible. Limits of detection for all nine acids range from 0.180 to 1.53ppm (2.16-19.3 pmoles) and limits of quantitation range from 0.549 to 3.45ppm (6.48-43.0 pmoles). In addition, the method was tested on two other reversed phase C18 columns of similar dimensions and particle diameter from different companies. Neither column showed quite the same peak resolution as the original column, however slight modifications to the mobile phase could improve the separation. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Ion Exchange and Liquid Column Chromatography.

    Science.gov (United States)

    Walton, Harold F.

    1980-01-01

    Emphasizes recent advances in principles and methodology in ion exchange and chromatography. Two tables list representative examples for inorganic ions and organic compounds. Cites 544 references. (CS)

  14. Atmospheric Pressure Glow Discharge with Liquid Electrode

    Science.gov (United States)

    Tochikubo, Fumiyoshi

    2013-09-01

    Nonthermal atmospheric pressure plasmas in contact with liquid are widely studied aiming variety of plasma applications. DC glow discharge with liquid electrode is an easy method to obtain simple and stable plasma-liquid interface. When we focus attention on liquid-phase reaction, the discharge system is considered as electrolysis with plasma electrode. The plasma electrode will supply electrons and positive ions to the liquid surface in a different way from the conventional metal electrode. However, the phenomena at plasma-liquid interface have not been understood well. In this work, we studied physical and chemical effect in liquid induced by dc atmospheric pressure glow discharge with liquid electrode. The experiment was carried out using H-shaped Hoffman electrolysis apparatus filled with electrolyte, to separate the anodic and cathodic reactions. Two nozzle electrodes made of stainless steel are set about 2 mm above the liquid surface. By applying a dc voltage between the nozzle electrodes, dc glow discharges as plasma electrodes are generated in contact with liquid. As electrolyte, we used aqueous solutions of NaCl, Na2SO4, AgNO3 and HAuCl4. AgNO3 and HAuCl4 are to discuss the reduction process of metal ions for synthesis of nanoparticles (NPs). OH radical generation yield in liquid was measured by chemical probe method using terephthalic acid. Discharge-induced liquid flow was visualized by Schlieren method. Electron irradiation to liquid surface (plasma cathode) generated OH- and OH radical in liquid while positive ion irradiation (plasma anode) generated H+ and OH radical. The generation efficiency of OH radical was better with plasma anode. Both Ag NPs in AgNO3 and Au NPs in HAuCl4 were synthesized with plasma cathode while only Au NPs were generated with plasma anode. Possible reaction process is qualitatively discussed. The discharge-induced liquid flow such as convection pattern was strongly influenced by the gas flow on the liquid surface. This work

  15. Investigation of Symphytum cordatum alkaloids by liquid-liquid partitioning, thin-layer chromatography and liquid chromatography-ion-trap mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Mroczek, Tomasz [Department of Pharmacognosy with Medicinal Plants Laboratory, Medical University, 1 Chodzki St., 20-093 Lublin (Poland)]. E-mail: tmroczek@pharmacognosy.org; Ndjoko-Ioset, Karine [Laboratoire de Pharmacognosie et Phytochimie, Ecole de Pharmacie Geneve-Lausanne, Universite de Geneve, Quai Ernest-Ansermet 30, CH-1211 Geneva 4 (Switzerland); Glowniak, Kazimierz [Department of Pharmacognosy with Medicinal Plants Laboratory, Medical University, 1 Chodzki St., 20-093 Lublin (Poland); Mietkiewicz-Capala, Agnieszka [Department of Pharmacognosy with Medicinal Plants Laboratory, Medical University, 1 Chodzki St., 20-093 Lublin (Poland); Hostettmann, Kurt [Laboratoire de Pharmacognosie et Phytochimie, Ecole de Pharmacie Geneve-Lausanne, Universite de Geneve, Quai Ernest-Ansermet 30, CH-1211 Geneva 4 (Switzerland)

    2006-05-04

    From the alkalised crude extract of Symphytum cordatum (L.) W.K. roots, pyrrolizidine alkaloids (PAs) were extracted as free tertiary bases and polar N-oxides in a merely one-step liquid-liquid partitioning (LLP) in separation funnel and subsequently pre-fractionated by preparative multiple-development (MD) thin-layer chromatography (TLC) on silica gel plates. In this way three alkaloid fractions of different polarities and retention on silica gel plates were obtained as: the most polar N-oxides of the highest retention, the tertiary bases of medium retention, and diesterified N-oxides of the lowest retention. The former fraction was reduced into free bases by sodium hydrosulfite and purified by LLP on Extrelut-NT3 cartridge. It was further analysed together with the two other fractions by high-performance liquid chromatography (HPLC)-ion-trap mass spectrometry with atmospheric pressure chemical ionization (APCI) interface on XTerra C{sub 18} column using a gradient elution. Based on MS {sup n} spectra, 18 various alkaloids have been tentatively determined for the first time in this plant as the following types of structure: echimidine-N-oxide (three diasteroisomers), 7-sarracinyl-9-viridiflorylretronecine (two diasteroisomers), echimidine (two diasteroisomers), lycopsamine (two diasteroisomers), dihydroechinatine-N-oxide, dihydroheliospathuline-N-oxide, lycopsamine-N-oxide (three diasteroisomers), 7-acetyllycopsamine-N-oxide, symphytine-N-oxide (two diasteroisomers) and 2'',3''-epoxyechiumine-N-oxide.

  16. High-Performance Liquid Chromatography: An Overview

    OpenAIRE

    Tandia N; Singh SK1; Kumar N; Singh S

    2013-01-01

    Chromatography is considered extremely powerful separation technique for variety of samples. Thecommon feature of all these techniques is that the different components in a sample mixture aredistributed between two phases, one of which remains stationary while the other the mobile phase, runsthrough the interstices or over the surface of the fixed phase. The movement of the mobile phase resultsin differential migration of the sample components. High performance thin layer chromatography is an...

  17. Analysis of Tocopherols by High Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    B. Edison

    2009-01-01

    Full Text Available : Gas chromatography is the key technique for organic components and also for tocopherols analysis. High performance liquid chromatography has an important role to take part in applications such as the handling of less usual samples, prevention of degradation of heat sensitive functional groups and for micro preparative purposes. Many approaches for development of improved methods are suggested, especially for reversed phase applications.

  18. Performance of the same column in supercritical fluid chromatography and in liquid chromatography.

    Science.gov (United States)

    Lambert, Nándor; Felinger, Attila

    2015-08-28

    We have studied the chromatographic behavior of the homologous series of alkylbenzenes (ranging from octylbenzene to octadecylbenzene) on the same C18 reversed-phase column in supercritical fluid chromatography (SFC) and reversed phase liquid chromatography (RPLC) at various experimental conditions, such as different eluent compositions, flow-rates, and mobile phase densities. The first and the second moments of the peaks were used to estimate the overall mass-transfer processes in both chromatographic modes using the stochastic model of chromatography. The results confirm that in SFC - as the density of the mobile phase is influenced by the flow-rate - there is a broader variation of mass-transfer properties than in liquid chromatography. As expected, the optimum mobile phase velocity is higher in SFC, but there is no real difference in the minimum value of plate height, i.e. in the optimum efficiency.

  19. Liquid Chromatography Applied to Space System

    Science.gov (United States)

    Poinot, Pauline; Chazalnoel, Pascale; Geffroy, Claude; Sternberg, Robert; Carbonnier, Benjamin

    Searching for signs of past or present life in our Solar System is a real challenge that stirs up the curiosity of scientists. Until now, in situ instrumentation was designed to detect and determine concentrations of a wide number of organic biomarkers. The relevant method which was and still is employed in missions dedicated to the quest of life (from Viking to ExoMars) corresponds to the pyrolysis-GC-MS. Along the missions, this approach has been significantly improved in terms of extraction efficiency and detection with the use of chemical derivative agents (e.g. MTBSTFA, DMF-DMA, TMAH…), and in terms of analysis sensitivity and resolution with the development of in situ high-resolution mass spectrometer (e.g. TOF-MS). Thanks to such an approach, organic compounds such as amino acids, sugars, tholins or polycyclic aromatic hydrocarbons (PAHs) were expected to be found. However, while there’s a consensus that the GC-MS of Viking, Huygens, MSL and MOMA space missions worked the way they had been designed to, pyrolysis is much more in debate (Glavin et al. 2001; Navarro-González et al. 2006). Indeed, (1) it is thought to remove low levels of organics, (2) water and CO2 could interfere with the detection of likely organic pyrolysis products, and (3) only low to mid-molecular weight organic molecules can be detected by this technique. As a result, researchers are now focusing on other in situ techniques which are no longer based on the volatility of the organic matter, but on the liquid phase extraction and analysis. In this line, micro-fluidic systems involving sandwich and/or competitive immunoassays (e.g. LMC, SOLID; Parro et al. 2005; Sims et al. 2012), micro-chip capillary electrophoreses (e.g. MOA; Bada et al. 2008), or nanopore-based analysis (e.g. BOLD; Schulze-Makuch et al. 2012) have been conceived for in situ analysis. Thanks to such approaches, molecular biological polymers (polysaccharides, polypeptides, polynucleotides, phospholipids, glycolipids

  20. Analysis of ganciclovir and its related substances using high performance liquid chromatography and liquid chromatography-mass spectrometry methods

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    Objective High performance liquid chromatography(HPLC)and liquid chromatography-mass spectrometry(LC/MS)methods were developed for the determination of ganciclovir and its related substances.Methods A Hypersil ODS2 column(4.6 mm×250 mm,5 μm)was used with a mobile phase of 0.02 M potassium dihydrogen phosphate buffer(pH 6.0)-methanol(92∶8)at a flow rate of 1.0 mL/min,and UV detector set at 254 nm was used for monitoring the eluents.Results The method was simple,rapid,selective and capable of separating all r...

  1. Monitoring stevioside in soju by high-performance liquid chromatography and liquid chromatography/mass spectrometry.

    Science.gov (United States)

    Ni, Fan; Ammann, Jeffrey; Mabud, Abdul

    2007-01-01

    A method using high-performance liquid chromatography (HPLC) with UV absorption detection was developed to monitor stevioside in soju, a distilled spirits product that is commercially available. The method uses a single-step dilution for sample preparation. It completely eliminates the time-consuming process of solid-phase extraction. A method using HPLC/mass spectrometry was optimized to confirm the identities of stevioside and other related impurities, including rebaudioside A, rebaudioside C, and dulcoside. The method was validated. The validation parameters included range (10.1-1007.3 ppm), precision, linearity, accuracy, robustness, system suitability, and intermediate precision. Stevioside standard solutions at 6 concentration levels were prepared for the validation work, including the tests for precision, linearity, and accuracy. The solutions were prepared in triplicate for each concentration. The relative standard deviation for the precision test was 0.999. The average recovery ranged from 95.7 to 101.1% for the soju samples spiked with stevioside standard. The detection limit for stevioside was estimated at 75 ppb. The method was used to screen several soju samples; no detectable stevioside was found in the samples.

  2. Liquid chromatography and liquid chromatography-mass spectrometry analysis of donepezil degradation products

    Directory of Open Access Journals (Sweden)

    Mladenović Aleksandar R.

    2015-01-01

    Full Text Available This study describes the investigation of degradation products of donepezil (DP using stability indicating RP-HPLC method for determination of donepezil, which is a centrally acting reversible acetylcholinesterase inhibitor. In order to investigate the stability of drug and formed degradation products, a forced degradation study of drug sample and finished product under different forced degradation conditions has been conducted. Donepezil hydrochloride and donepezil tablets were subjected to stress degradation conditions recommended by International Conference on Harmonization (ICH. Donepezil hydrochloride solutions were subjected to acid and alkali hydrolysis, chemical oxidation and thermal degradation. Significant degradation was observed under alkali hydrolysis and oxidative degradation conditions. Additional degradation products were observed under the conditions of oxidative degradation. The degradation products observed during forced degradation studies were monitored using the high performance liquid chromatography (HPLC method developed. The parent method was modified in order to obtain LC-MS compatible method which was used to identify the degradation products from forced degradation samples using high resolution mass spectrometry. The mass spectrum provided the precise mass from which derived molecular formula of drug substance and degradation products formed and proved the specificity of the method unambiguously. [Projekat Ministarstva nauke Republike Srbije, br. 172013

  3. Towards early detection of the hydrolytic degradation of poly(bisphenol A)carbonate by hyphenated liquid chromatography and comprehensive two-dimensional liquid chromatography

    NARCIS (Netherlands)

    Coulier, L.; Kaal, E.R.; Hankemeier, Th.

    2006-01-01

    The hydrolytic degradation of poly(bisphenol A)carbonate (PC) has been characterized by various liquid chromatography techniques. Size exclusion chromatography (SEC) showed a significant decrease in molecular mass as a result of hydrolytic degradation, while 'liquid chromatography at critical

  4. Towards early detection of the hydrolytic degradation of poly(bisphenol A)carbonate by hyphenated liquid chromatography and comprehensive two-dimensional liquid chromatography

    NARCIS (Netherlands)

    Coulier, L.; Kaal, E.R.; Hankemeier, Th.

    2006-01-01

    The hydrolytic degradation of poly(bisphenol A)carbonate (PC) has been characterized by various liquid chromatography techniques. Size exclusion chromatography (SEC) showed a significant decrease in molecular mass as a result of hydrolytic degradation, while 'liquid chromatography at critical condit

  5. Mallow carotenoids determined by high-performance liquid chromatography

    Science.gov (United States)

    Mallow (corchorus olitorius) is a green vegetable, which is widely consumed either fresh or dry by Middle East population. This study was carried out to determine the contents of major carotenoids quantitatively in mallow, by using a High Performance Liquid Chromatography (HPLC) equipped with a Bis...

  6. Determination of Caffeine in Beverages by High Performance Liquid Chromatography.

    Science.gov (United States)

    DiNunzio, James E.

    1985-01-01

    Describes the equipment, procedures, and results for the determination of caffeine in beverages by high performance liquid chromatography. The method is simple, fast, accurate, and, because sample preparation is minimal, it is well suited for use in a teaching laboratory. (JN)

  7. Multichannel Detection in High-Performance Liquid Chromatography.

    Science.gov (United States)

    Miller, James C.; And Others

    1982-01-01

    A linear photodiode array is used as the photodetector element in a new ultraviolet-visible detection system for high-performance liquid chromatography (HPLC). Using a computer network, the system processes eight different chromatographic signals simultaneously in real-time and acquires spectra manually/automatically. Applications in fast HPLC…

  8. High-Performance Liquid Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Vestal, Marvin L.

    1984-01-01

    Reviews techniques for online coupling of high-performance liquid chromatography with mass spectrometry, emphasizing those suitable for application to nonvolatile samples. Also summarizes the present status, strengths, and weaknesses of various techniques and discusses potential applications of recently developed techniques for combined liquid…

  9. Ultra high performance liquid chromatography of seized drugs

    NARCIS (Netherlands)

    Lurie, I.S.

    2010-01-01

    The primary goal of this thesis is to investigate the use of ultra high performance liquid chromatography (UHPLC) for the analysis of seized drugs. This goal was largely achieved and significant progress was made in achieving improved separation and detection of drugs of forensic interest.

  10. High-performance liquid chromatography with packed microchips

    OpenAIRE

    Ehlert, Steffen

    2011-01-01

    This work is explaining the importance of generating a densely packed chromatographic bed to achieve optimum separation efficiency in miniaturized liquid chromatography. The reduction of peak dispersion and enhancement of separation efficiency is the important problem in micro- and nano-separation that is to be solved to generate highly efficient chromatographic systems that can exploit all advantages of miniaturization. Therefore...

  11. Characterisation of cholera toxin by liquid chromatography - Electrospray mass spectrometry

    NARCIS (Netherlands)

    Baar, B.L.M. van; Hulst, A.G.; Wils, E.R.J.

    1999-01-01

    Cholera toxin, one of the toxins that may be generated by various strains of the bacterium Vibrio cholerae, can be considered as a substance possibly used in biological warfare. The possibilities of characterising the toxin by liquid chromatography electrospray mass spectrometry (LC-ES-MS) were inve

  12. Characterisation of cholera toxin by liquid chromatography - Electrospray mass spectrometry

    NARCIS (Netherlands)

    Baar, B.L.M. van; Hulst, A.G.; Wils, E.R.J.

    1999-01-01

    Cholera toxin, one of the toxins that may be generated by various strains of the bacterium Vibrio cholerae, can be considered as a substance possibly used in biological warfare. The possibilities of characterising the toxin by liquid chromatography electrospray mass spectrometry (LC-ES-MS) were

  13. Advancing liquid chromatography- mass spectrometry based technologies for proteome research

    NARCIS (Netherlands)

    Boersema, P.J.

    2010-01-01

    In proteomics, high-tech nano-liquid chromatography (LC) and mass spectrometry (MS) instrumentation is used to routinely sequence proteins at a large scale. In this thesis, several technological developments are described to advance proteomics and their applicability is demonstrated in several diffe

  14. Quantification of Tea Flavonoids by High Performance Liquid Chromatography

    Science.gov (United States)

    Freeman, Jessica D.; Niemeyer, Emily D.

    2008-01-01

    We have developed a laboratory experiment that uses high performance liquid chromatography (HPLC) to quantify flavonoid levels in a variety of commercial teas. Specifically, this experiment analyzes a group of flavonoids known as catechins, plant-derived polyphenolic compounds commonly found in many foods and beverages, including green and black…

  15. Coupling of column liquid chromatography and Fourier transform infrared spectrometry

    NARCIS (Netherlands)

    Somsen, G.W; Gooijer, C; Velthorst, N.H; Brinkman, U.A Th

    1998-01-01

    This paper provides an extensive overview of the literature on the coupling of column liquid chromatography (LC) and Fourier transform infrared spectrometry (FT-IR). Flow-cell-based FT-IR detection and early solvent-elimination interfaces for LC-FT-IR are discussed in brief. A comprehensive descript

  16. Alternative solvents can make preparative liquid chromatography greener

    NARCIS (Netherlands)

    Shen, Y.; Chen, B.; Beek, van T.A.

    2015-01-01

    To make preparative Reversed-Phase High Performance Liquid Chromatography (RP-pHPLC) greener, alternative solvents were considered among others in terms of toxicity, cost, safety, workability, chromatographic selectivity and elution strength. The less toxic solvents ethanol, acetone and ethyl acetat

  17. Challenges in polymer analysis by liquid chromatography

    NARCIS (Netherlands)

    E. Uliyanchenko; S. van der Wal; P.J. Schoenmakers

    2012-01-01

    Synthetic polymers are very important in our daily life. Many valuable properties of polymers are determined by their molecular weight and chemical composition. Liquid chromatographic (LC) techniques are very commonly used for molecular characterisation of polymers. LC analysis of macromolecules is

  18. Analysis of Free Fatty Acids on the Fingertips by High Performance Liquid Chromatography.

    Science.gov (United States)

    1978-12-20

    This investigation studied the efficiency of high performance liquid chromatography in the determination of free fatty acids present on the...utilized to eliminate the microbial contamination. The high performance liquid chromatography provided excellent separation of skin fatty acids for

  19. A Review on Ultra Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    Darasanapalli Meenakshi

    2013-06-01

    Full Text Available UPLC is a rising chromatographic separation technique whose packing materials have smaller particle size lesser than 2.5μm which improves the speed, resolution and sensitivity of analysis. When many scientists experienced separation barriers with conventional HPLC, UPLC extended and expanded the utility of chromatography. The main advantage is a reduction of analysis time which also reduces solvent consumption. The analysis time, solvent consumption and analysis cost are very important factor in many analytical laboratories. The time spent for optimizing new methods can also be greatly reduced. This results in many analysis in a day and quick results which is of very importance to the industries and research laboratories. UPLC principle is same as that of HPLC that is based on Van Deemter equation but decrease in particle size has increased efficiency at increased flow rates.

  20. Determination of a Jet Fuel Metal Deactivator by High Performance Liquid Chromatography

    Science.gov (United States)

    1983-06-01

    HIGH PERFORMANCE LIQUID CHROMATOGRAPHY Paul C. Hayes, Jr. Fuels Branch...SUPPLEMENTARY NOTES 19. KEY WORDS (Continue on reverse side if necessary and identify by block number) High Performance Liquid Chromatography absorbance...SYMBOL HPLC High Performance Liquid Chromatography P-4 jet propulsion fuel, wide-boiling range, conforming to MIL-T-5624L MDA metal deactivator,

  1. Determination of Stabiliser Contents in Advanced Gun Propellants by Reverse Phase High Performance Liquid Chromatography

    Science.gov (United States)

    1994-03-01

    HIGH PERFORMANCE LIQUID CHROMATOGRAPHY N"m A.R. TURNER AND A. WHITE...TO biEPROOU.; AND SELL THIS REPORT Determination of Stabiliser Contents in Advanced Gun Propellants by Reverse Phase High Performance Liquid Chromatography A.R...8217/......... .. Availability Cooes Dist Avaiardlo A-i Determination of Stabiliser Contents in Advanced Gun Propellants by Reverse Phase High Performance Liquid Chromatography

  2. Theories to support method development in comprehensive two-dimensional liquid chromatography - A review

    NARCIS (Netherlands)

    Bedani, F.; Schoenmakers, P.J.; Janssen, H.-G.

    2012-01-01

    On-line comprehensive two-dimensional liquid chromatography techniques promise to resolve samples that current one-dimensional liquid chromatography methods cannot adequately deal with. To make full use of the potential of two-dimensional liquid chromatography, optimization is required. Optimization

  3. 21 CFR 862.2260 - High pressure liquid chromatography system for clinical use.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false High pressure liquid chromatography system for... Clinical Laboratory Instruments § 862.2260 High pressure liquid chromatography system for clinical use. (a) Identification. A high pressure liquid chromatography system for clinical use is a device intended to...

  4. 21 CFR 862.2250 - Gas liquid chromatography system for clinical use.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Gas liquid chromatography system for clinical use... Instruments § 862.2250 Gas liquid chromatography system for clinical use. (a) Identification. A gas liquid chromatography system for clinical use is a device intended to separate one or more drugs or compounds from...

  5. Optimizing heterosurface adsorbent synthesis for liquid chromatography

    Science.gov (United States)

    Bogoslovskii, S. Yu.; Serdan, A. A.

    2016-03-01

    The structural and geometric parameters of a silica matrix (SM) for the synthesis of heterosurface adsorbents (HAs) are optimized. Modification is performed by shielding the external surfaces of alkyl-modified silica (AS) using human serum albumin and its subsequent crosslinking. The structural and geometric characteristics of the SM, AS, and HA are measured via low-temperature nitrogen adsorption. It is found that the structural characteristics of AS pores with diameters D 9 nm reduces significantly due to adsorption of albumin. It is concluded that silica gel with a maximum pore size distribution close to 5 nm and a minimal proportion of pores with D > 9 nm is optimal for HA synthesis; this allows us to achieve the greatest similarity between the chromatographic retention parameters for HA and AS. The suitability of the synthesized adsorbents for analyzing drugs in biological fluids through direct sample injection is confirmed by chromatography. It was found that the percentage of the protein fraction detected at the outlet of the chromatographic column is 98%.

  6. Standard flow liquid chromatography for shotgun proteomics in bioenergy research.

    Science.gov (United States)

    González Fernández-Niño, Susana M; Smith-Moritz, A Michelle; Chan, Leanne Jade G; Adams, Paul D; Heazlewood, Joshua L; Petzold, Christopher J

    2015-01-01

    Over the past 10 years, the bioenergy field has realized significant achievements that have encouraged many follow on efforts centered on biosynthetic production of fuel-like compounds. Key to the success of these efforts has been transformational developments in feedstock characterization and metabolic engineering of biofuel-producing microbes. Lagging far behind these advancements are analytical methods to characterize and quantify systems of interest to the bioenergy field. In particular, the utilization of proteomics, while valuable for identifying novel enzymes and diagnosing problems associated with biofuel-producing microbes, is limited by a lack of robustness and limited throughput. Nano-flow liquid chromatography coupled to high-mass accuracy, high-resolution mass spectrometers has become the dominant approach for the analysis of complex proteomic samples, yet such assays still require dedicated experts for data acquisition, analysis, and instrument upkeep. The recent adoption of standard flow chromatography (ca. 0.5 mL/min) for targeted proteomics has highlighted the robust nature and increased throughput of this approach for sample analysis. Consequently, we assessed the applicability of standard flow liquid chromatography for shotgun proteomics using samples from Escherichia coli and Arabidopsis thaliana, organisms commonly used as model systems for lignocellulosic biofuels research. Employing 120 min gradients with standard flow chromatography, we were able to routinely identify nearly 800 proteins from E. coli samples; while for samples from Arabidopsis, over 1,000 proteins could be reliably identified. An examination of identified peptides indicated that the method was suitable for reproducible applications in shotgun proteomics. Standard flow liquid chromatography for shotgun proteomics provides a robust approach for the analysis of complex samples. To the best of our knowledge, this study represents the first attempt to validate the standard

  7. Standard flow liquid chromatography for shotgun proteomics in bioenergy research

    Directory of Open Access Journals (Sweden)

    Susana M. González Fernández-Niño

    2015-04-01

    Full Text Available Over the past ten years the bioenergy and biofuels field has realized significant achievements that have encouraged many follow on efforts centered on biosynthetic production of fuel-like compounds. Key to the success of these efforts has been transformational developments in feedstock characterization and metabolic engineering of biofuel-producing microbes. Lagging far behind these advancements are analytical methods to characterize and quantify systems of interest to the bioenergy field. In particular the utilization of proteomics, while valuable for identifying novel enzymes and diagnosing problems associated with biofuel-producing microbes, is limited by a lack of robustness and limited throughput. Nano-flow liquid chromatography coupled to high-mass accuracy, high-resolution mass spectrometers has become the dominant approach for the analysis of complex proteomic samples, yet such assays still require dedicated experts for data acquisition, analysis, and instrument upkeep. The recent adoption of standard flow chromatography (ca. 0.5 mL/min for targeted proteomics has highlighted the robust nature and increased throughput of this approach for sample analysis. Consequently, we assessed the applicability of standard flow liquid chromatography for shotgun proteomics using samples from Escherichia coli and Arabidopsis thaliana, organisms commonly used as model systems for lignocellulosic biofuels research. Employing 120 minute gradients with standard flow chromatography we were able to routinely identify nearly 800 proteins from E. coli samples, while for samples from Arabidopsis over 1,000 proteins could be reliably identified. An examination of identified peptides indicated that the method was suitable for reproducible applications in shotgun proteomics. Standard flow liquid chromatography for shotgun proteomics provides a robust approach for the analysis of complex samples. To the best of our knowledge this study represents the first attempt

  8. Nano-liquid chromatography applied to enantiomers separation.

    Science.gov (United States)

    Fanali, Salvatore

    2017-02-24

    This paper presents the state of the art concerning the separation of chiral compounds by means of nano-liquid chromatography (nano-LC). The enantiomers' separation and determination are a subject of fundamental importance in various application fields such as pharmaceutical industry, biomedicine, food, agrochemical etc. Nano-LC is a miniaturized chromatographic technique offering some advantages over conventional ones such as low consumption of mobile phase, sample volume and amount of chiral stationary phase, reduced costs etc. This is reported in the first part of the paper illustrating the features of the nano-LC. In addition, chiral resolution methods are briefly illustrated. Some chiral selectors, used in high-performance liquid chromatography have also been applied in nano-LC including cyclodextrins, glycopeptide antibiotics, modified polysaccharides etc. This is discussed in the second part of the review. Finally some examples of the applications available in literature are reported.

  9. Application of fast liquid chromatography for antioxidants analysis

    Directory of Open Access Journals (Sweden)

    Agnieszka Drożdżyńska

    2012-03-01

    Full Text Available Background. An intensive development of the Fast Liquid Chromatography (FLC has been recently observed. It makes possible to reduce time analysis and improve resolution as well as sensitivity. The aim of this study was to separate the chosen antioxidants optimization using the FLC method. Material  and methods. The three various procedures for antioxidants analysis were compared. Mobile phases containing aqueous solution of formic acid, acetic acid, acetonitrile, and methanol were tested. Limit of detection (LOD, limit of quantification (LOQ, linearity and repeatability of each procedures were determined. Results. Developed procedure enabled to separate all analytes and allowed to get low LOD levels and good repeatability. This procedure was used for antioxidants analysis in buckwheat and buckwheat products. Conclusion. Fast Liquid Chromatography allows to  reduce time analysis and  obtain good  validation parameters.

  10. Temperature-Modulated Array High-Performance Liquid Chromatography

    OpenAIRE

    Premstaller, Andreas; Xiao, Wenzhong; Oberacher, Herbert; O'Keefe, Matthew; Stern, David; Willis, Thomas; Huber, Christian G.; Peter J. Oefner

    2001-01-01

    Using novel monolithic poly(styrene-divinylbenzene) capillary columns with an internal diameter of 0.2 mm, we demonstrate for the first time the feasibility of constructing high-performance liquid chromatography arrays for the detection of mutations by heteroduplex analysis under partially denaturing conditions. In one embodiment, such an array can be used to analyze one sample simultaneously at different temperatures to maximize the detection of mutations in DNA fragments containing multiple...

  11. Determination of serotonin released from coffee wax by liquid chromatography.

    Science.gov (United States)

    Kele, M; Ohmacht, R

    1996-04-12

    A simple hydrolysis and extraction method was developed for the release of serotonin (5-hydroxytryptamine) from a coffee wax sample obtained from decaffeination of coffee beans. The recoverable amount of serotonin was determined by reversed-phase high-performance liquid chromatography with gradient elution and UV detection, using the standard addition method. Different type of basic deactivated chromatographic columns were used for the separation.

  12. Determination of aminocresol isomers by high-speed liquid chromatography.

    Science.gov (United States)

    Sakurai, H; Kito, M

    Aminocresol isomers (4-hydroxy-m-toluidine [II], 3-hydroxy-p-toluidine [II], 2-hydroxy-p-toluidine [III]) and p-aminophenol have been separated and determined by a high-speed liquid Chromatographie method. Since this method is applicable in aqueous media, it was used to investigate the suitability of a haemin-cysteine system as a model for the cytochrome P-450 mono-oxygenase system, by determination of the [I], [II], [III] and p-aminophenol formed.

  13. Fiber Bragg grating photoacoustic detector for liquid chromatography.

    Science.gov (United States)

    Yang, Qingxin; Loock, Hans-Peter; Kozin, Igor; Pedersen, David

    2008-11-01

    Fiber Bragg Gratings (FBGs) are known to be sensitive acoustic transducers and have previously been used for the photoacoustic detection of small solid samples. Here, we demonstrate the use of an FBG as an on-line detector for liquid chromatography. The FBG was inserted into a silica capillary and the photoacoustic response from the effluent was generated by a 10 ns pulsed laser. The acoustic pulse was quantified by the FBG through a characteristic change in the reflection spectrum. Good repeatability and linear response were obtained over three orders of magnitude (R(2) > 0.99), and the limit of detection of Coumarin 440 was determined to be 5 microM. The technique was successfully coupled to high performance liquid chromatography and applied to on-line analysis of a three-compound solution. Photoacoustic detection in liquid chromatography using FBGs is a label-free method, which can be applied to the detection of any chromogenic compound irrespective of its fluorogenic properties. It is a simple, inexpensive, and inherently micron-sized technique, insensitive to electromagnetic interference.

  14. Thermal expansion pump for capillary high-performance liquid chromatography.

    Science.gov (United States)

    Tao, Qian; Wu, Qian; Zhang, Xiangmin

    2010-02-01

    A thermal expansion pump (TEP) based on a principle of liquid thermal expansion for capillary high-performance liquid chromatography has been developed. The novel pump is capable of generating a continuous flow at high pressure for constant and stable delivery of binary solvents from nanoliters to microliters per minute without splitting. Theoretical equations for controlling fluidic output of this pump have been established and validated by a series of experiments. Factors affecting flow rate, such as density discrepancy, liquid compressibility, and mass loss in output, were taken into account. An assembly of the pump system employing two groups of thermal expansion pumps (TEPs) working in turns were fabricated, and a controlling strategy for the pump system to maintain a continuous delivery without pressure fluctuation even at switching points was also developed. Both isocratic and gradients of binary solvent delivery by the TEPs were performed. Reproducibility and standard deviation at different flow rates were determined. A capillary high-performance liquid chromatography (micro-HPLC) system consisting of the TEPs, an injection valve, a homemade packed capillary column (20 cm x 100 microm i.d. with 5 microm C18), and a laser-induced fluorescence detector was set up, and sample separations were carried out. Results of RSD = 4% for flow and RSD = 2% for retention times at 500 nL/min were achieved. Such a pump system has almost no moving parts except for the solvent switches. Its overall costs of manufacture and running are very low. It is proven that the TEPs system has great potential and competitive capabilities in capillary liquid chromatography.

  15. Liquid chromatography-mass spectroscopy and liquid chromatography-ultraviolet/visible photodiode array analysis of selected colchicum species.

    Science.gov (United States)

    Gharaibeh, Ahmad A; Al-Serini, Ala'a; Qasaymeh, Rana M; Ma'aya'h, Amani S; Tawaha, Khaled; El-Elimat, Tamam; Alali, Feras Q

    2012-01-01

    An in-house strategy to dereplicate colchicinoid alkaloids was recently developed by our team. It aimed at quickly identifying Colchicum constituents using LC-MS (liquid chromatography-mass spectroscopy) and LC-UV/Vis PDA (liquid chromatography-ultraviolet/ visible photodiode array) techniques. In this project, our goal was to validate the developed method through analysing the alkaloid-rich fractions of three Colchicum species that had been previously studied phytochemically using the traditional bioactivity-guided fractionation methodology. The analysed species were Colchicum tauri Siehe ex Stefanoff, Colchicum stevenii Kunth, and Colchicum tunicatum Feinbr., all belonging to the family Colchicaceae. In addition to identifying the compounds previously isolated and characterized by the traditional methodology, the new strategy succeeded in tentatively identifying a set of known compounds, but new to the species.

  16. HPLC separation and GC-MS identification of the polar components of coal liquids. [High pressure liquid chromatography, gas chromatography-mass spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Satoh, M.; Tanabe, K.; Uchino, H.; Yokoyama, S.; Sanada, Y.

    1984-01-01

    The polar components in the 200-400 C fraction of Akabira coal liquids were separated by high pressure liquid chromatography using an amine-based column. By varying the CHCl/sub 3/ concentration in the solvent, basic, neutral and acid fractions were obtained. These were then investigated separately using infrared spectroscopy, flame ionization detection-gas chromatography and gas chromatography-mass spectroscopy. The basic fraction contained alkyltetrahydroquinolines, the neutral fraction, alkylphenols and alkylcarbazoles; and the acid fraction, alkylphenols. 15 references.

  17. Characteristics of liquid flow induced by atmospheric-pressure DC glow discharge in contact with liquid

    Science.gov (United States)

    Tochikubo, Fumiyoshi; Aoki, Takuya; Shirai, Naoki; Uchida, Satoshi

    2017-04-01

    In this work, we investigated the characteristics of liquid flow induced by atmospheric-pressure dc glow discharge in contact with a liquid. The spatiotemporal development of liquid flow was visualized by the schlieren method, and the temperature distribution was measured using microencapsulated thermotropic liquid crystal particles dispersed in a liquid. We confirmed the appearance of specific downward liquid flow immediately below the dc glow discharge. The characteristics of downward liquid flow were reproduced by fluid simulation considering a downward driving force at the plasma–liquid interface. Our results suggest that the probable driving force for the downward liquid flow was the momentum transfer of charged species at the liquid surface.

  18. Optimized determination of polybrominated diphenyl ethers by ultrasound-assisted liquid-liquid extraction and high-performance liquid chromatography.

    Science.gov (United States)

    He, Kuang; Lv, YuanCai; Chen, YuanCai

    2014-10-01

    A method based on ultrasound-assisted liquid-liquid extraction and high-performance liquid chromatography has been optimized for the determination of six polybrominated diphenyl ether congeners. The optimal condition relevant to the extraction was first investigated, more than 98.7 ± 0.7% recovery was achieved with dichloromethane as extractant, 5 min extraction time, and three cycles of ultrasound-assisted liquid-liquid extraction. Then multiple function was employed to optimize polybrominated diphenyl ether detection conditions with overall resolution and chromatography signal area as the responses. The condition chosen in this experiment was methanol/water 93:7 v/v, flow rate 0.80 mL/min, column temperature 30.0°C. The optimized technique revealed good linearity (R(2) > 0.9962 over a concentration range of 1-100 μg/L) and repeatability (relative standard deviation liquid-liquid extraction coupled with high-performance liquid chromatography was effective to identify and quantify the complex polybrominated diphenyl ethers in effluent samples.

  19. Ionic Liquids as Mobile Phase Additives for Separation of Nucleotides in High-Performance Liquid Chromatography

    Institute of Scientific and Technical Information of China (English)

    ZHANG,Wen-Zhu(张文珠); HE,Li-Jun(何丽君); LIU,Xia(刘霞); JIANG,Sheng-Xiang(蒋生祥)

    2004-01-01

    Ionic liquids are a type of salts that are liquid at low temperature (< 100 ℃). Because of their some special properties, they have been widely used as new "green solvents" for many chemical reactions and liquid-liquid extraction in the past several years. In this paper, a new method for the separation of nucleotides is developed and the essential feature of the method is that 1-alkyl-3-methylimidazolium salts are used as mobile phase additives, resulting in a baseline separation of nucleotides without need of gradient elution and need of organic solvent addition as currently used in RP-HPLC. This study shows the potential application of ionic liquids as mobile phase additives in reversed-phase liquid chromatography.

  20. Mass transfer mechanism in chiral reversed phase liquid chromatography.

    Science.gov (United States)

    Gritti, Fabrice; Guiochon, Georges

    2014-03-01

    The mechanism of mass transfer in chiral chromatography was investigated using an experimental protocol already applied in RPLC and HILIC chromatography. The different contributions to the reduced height equivalent to a theoretical plate (HETP) include the longitudinal diffusion HETP term, the solid-liquid mass transfer resistance HETP term, the short-range eddy dispersion HETP term, and the long-range eddy dispersion HETP term. Their accurate measurement permits the determination of the adsorption rate constant kads of trans-stilbene enantiomers on a column packed with Lux 5 μm Cellulose-1 particles. The experimental results demonstrate that the number of adsorption-desorption steps per unit time of chiral compounds on polysaccharide-based chiral stationary phases is four orders of magnitude smaller than that of achiral compounds.

  1. Modeling of closed-loop recycling liquid-liquid chromatography: Analytical solutions and model analysis.

    Science.gov (United States)

    Kostanyan, Artak E

    2015-08-07

    In closed-loop recycling (CLR) chromatography, the effluent from the outlet of a column is directly returned into the column through the sample feed line and continuously recycled until the required separation is reached. To select optimal operating conditions for the separation of a given feed mixture, an appropriate mathematical description of the process is required. This work is concerned with the analysis of models for the CLR separations. Due to the effect of counteracting mechanisms on separation of solutes, analytical solutions of the models could be helpful to understand and optimize chromatographic processes. The objective of this work was to develop analytical expressions to describe the CLR counter-current (liquid-liquid) chromatography (CCC). The equilibrium dispersion and cell models were used to describe the transport and separation of solutes inside a CLR CCC column. The Laplace transformation is applied to solve the model equations. Several possible CLR chromatography methods for the binary and complex mixture separations are simulated.

  2. MEMS Liquid and Gas Chromatography for Miniaturized Planetary In Situ Instruments

    Science.gov (United States)

    Kidd, R. D.; Bae, B.; Willis, P. A.; Noell, A. C.; Scianmarello, N.; Tai, Y.-C.

    2016-10-01

    Micro-Electro-Mechanical Systems (MEMS) technology to reduce the size, mass and power of the three classical chromatographic technologies: gas chromatography (GC), capillary electrophoresis (CE) and high performance liquid chromatography (HPLC).

  3. Purification of pituitary autoantigen by column liquid chromatography and chromatofocusing.

    Science.gov (United States)

    Gut, Paweł; Fischbach, Jakub; Ziemnicka, Katarzyna; Bączyk, Maciej; Baszko-Błaszyk, Daria; Wrotkowska, Elżbieta; Ruchała, Marek

    2014-01-01

    Pituitary autoantibodies can be determined both in patients with pituitary disease as well as patients with autoimmune endocrine diseases. The purpose of the study was to isolate and purify pituitary autoantigen using sera of patients and the microsomal fraction of the pituitary. To isolate a pituitary autoantigen, patient sera were used, which showed a strong immune response to pituitary antigens. Pituitary microsomal fractions were prepared from pituitary tissue homogenates. In the study, sera of patients with pituitary disease, Addison and Graves' disease were used. The initial stages were carried out by affinity chromatography on CN -Br sepharose column whereas purification was continued by column liquid chromatography on AcA54 Ultrogel. Chromatofocusing was performed by Polybuffer exchanger PBE 94. (125)I-labeled pituitary antigens after isolation appeared in column chromatography in three peaks. The first peak contained 50-70 kDa proteins, the second peak - 17 to 22 kDa proteins and the third peak contains (125)-iodides. Three fractions obtained from filtration on Ultrogel were separated in a polyacrylamide gel. In the first peak two bands 67 and 55 kDa appeared. The second peak contained low molecular weight substances, and the third peak contained (125)I. The first peak from Ultrogel was isolated by chromatofocusing - the first peak with pH 5.9 and the second one with pH 4.9. Isolation and purification of pituitary autoantigen with the use of column liquid chromatography and chromatofocusing resulted in obtainment of two antigenic proteins of specific gravity of 67 and 55 kDa.

  4. Quantification of tryptophan in plasma by high performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Renata Romanholi Pinhati

    2012-01-01

    Full Text Available A simple, rapid and selective method using high-performance liquid chromatography with ultraviolet detection (267 nm was applied for the determination of tryptophan in plasma. Separation was carried out on a C18 column (150 x 4.6 mm internal diameter in 6 min. The mobile phase consisted of 5 mM the sodium acetate and acetonitrile (92:8, v/v. The method was shown to be precise and accurate, and good recovery of analyte was achieved, characterizing the method as efficient and reliable for use in laboratory analysis.

  5. A novel ionic liquids grafted polysiloxane for capillary gas chromatography

    Institute of Scientific and Technical Information of China (English)

    Qing Quan Wei; Mei Ling Qi; Ruo Nong Fu

    2009-01-01

    A new ionic liquids grafted polysiloxane used as stationary phase for capillary gas chromatography(CGC)is described.The stationary phase of 1-vinyl-3-hexylimidazolium hexafluorophosphate anchored to polysiloxane(PMHS-[VHIm][PF6])was synthesized,characterized and coated onto capillary columns by static coating.The results show that the present stationary phase exhibits a very good chromatographic resolution and selectivity for Grob test mixture and alcohols with baseline resolution and symmetry peaks.The present work suggests that novel stationary phase has a great potential for further development and application.

  6. Gas-liquid chromatography in lunar organic analysis.

    Science.gov (United States)

    Gehrke, C. W.

    1972-01-01

    Gas-liquid chromatography (GLC) is a powerful and sensitive method for the separation and detection of organic compounds at nanogram levels. The primary requirement for successful analyses is that the compounds of interest must be volatile under the chromatographic conditions employed. Nonvolatile organic compounds must be converted to volatile derivatives prior to analysis. The derivatives of choice must be both amenable to chromatographic separation and be relatively stable. The condition of volatility necessitates the development of efficient derivatization reactions for important groups of compounds as amino acids, carbohydrates, nucleosides, etc. Trimethylsilylation and trifluoroacetylation represent specific areas of recent prominence. Some relevant practical aspects of GLC are discussed.

  7. Determination of Selected Colored Smokes on Glass Fiber Discs by High Performance Liquid Chromatography (HPLC)

    Science.gov (United States)

    1991-05-01

    High Performance Liquid Chromatography (HPLC) 12. PERSONAL AUTHOR(S) F F_ n.ipl’prifl. Alan R...GROUP SUB-GROUP High Performance Liquid Chromatography (HPLC), Analytical IMethod, 1,4-diamino-2,3-dihydroanthraquinone, 2-(2 - _ quinolinyl)-1,3...weights, low vapor pressures and low thermal stability. High performance liquid chromatography (HPLC) appears to be the analytical method of choice

  8. Determination of Stereoisomers of Epalrestat by Liquid Chromatography

    Institute of Scientific and Technical Information of China (English)

    齐美玲; 王鹏; 杨建军

    2004-01-01

    An isocratic reversed-phase liquid chromatographic (LC) method is described for the determination of epalrestat and its three stereoisomers (degradation impurities) in drug substance. The LC separation system consisted of a Hypersil C18 column (250 mm×4.6 mm, 5 μm) with a mobile phase comprising methanol, acetonitrile and water (volume ratio 60∶1∶50, pH 4.5) delivered at a flow rate of 1.6 mL/min and UV detection at 280 nm. The proposed LC method is simple and selective for the determination of the stereoisomers of epalrestat in the drug substance with a limit of detection and quantification of 3.9 μg/mL and 4.9 μg/mL, respectively. The stereoisomers were identified by liquid chromatography-mass spectrometry (LC-MS).

  9. A novel amide stationary phase for hydrophilic interaction liquid chromatography and ion chromatography.

    Science.gov (United States)

    Shen, Guobin; Zhang, Feifang; Yang, Bingcheng; Chu, Changhu; Liang, Xinmiao

    2013-10-15

    A novel amide stationary phase (ASP) for hydrophilic interaction liquid chromatography (HILIC) has been prepared via the Click chemistry method. It was based on the strategy that the amino group of Asparagine was easily transferred to the corresponding azido group and then clicked onto terminal alkyne-silica gel in the presence of Cu(I)-based catalyst. For the tested polar compounds including nucleosides and nucleic acid bases, ASP-based column has demonstrated good performance in terms of separation efficiency and column stability, and the retention mechanism was found to match well the typical HILIC retention. In addition, the ASP described here showed much better selectivity in separation of inorganic anions under ion chromatography mode relative to other kinds of commercial ASP.

  10. Fundamentals of the Theory of Capillary Gas-Liquid-Solid Chromatography

    Science.gov (United States)

    Berezkin, Viktor G.; Zolotarev, P. P.

    1984-11-01

    It is shown that the known instances of the separation of volatile compounds actually refer to gas-liquid-solid chromatography and not gas-liquid chromatography, the walls of the capillary column fulfilling the function of the solid. The theories of the retention and spreading of the chromatographic bands in elution gas-liquid-solid chromatography are examined. The results of theoretical and experimental studies indicate the need to take into account the role of adsorption in capillary gas-liquid chromatography. The bibliography includes 140 references.

  11. Analysis of Some Biogenic Amines by Micellar Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    Irena Malinowska

    2012-01-01

    Full Text Available Micellar liquid chromatography (MLC with the use of high performance liquid chromatography (HPLC was used to determine some physicochemical parameters of six biogenic amines: adrenaline, dopamine, octopamine, histamine, 2-phenylethylamine, and tyramine. In this paper, an influence of surfactant’s concentration and pH of the micellar mobile phase on the retention of the tested substances was examined. To determine the influence of surfactant’s concentration on the retention of the tested amines, buffered solutions (at pH 7.4 of ionic surfactant—sodium dodecyl sulfate SDS (at different concentrations with acetonitrile as an organic modifier (0.8/0.2 v/v were used as the micellar mobile phases. To determine the influence of pH of the micellar mobile phase on the retention, mobile phases contained buffered solutions (at different pH values of sodium dodecyl sulfate SDS (at 0.1 M with acetonitrile (0.8/0.2 v/v. The inverse of value of retention factor (1/ versus concentration of micelles ( relationships were examined. Other physicochemical parameters of solutes such as an association constant analyte—micelle (ma—and partition coefficient of analyte between stationary phase and water (hydrophobicity descriptor (swΦ were determined by the use of Foley’s equation.

  12. Dispersive liquid-liquid microextraction coupled to liquid chromatography for thiamine determination in foods.

    Science.gov (United States)

    Viñas, Pilar; López-García, Ignacio; Bravo-Bravo, María; Briceño, Marisol; Hernández-Córdoba, Manuel

    2012-05-01

    A miniaturized dispersive liquid-liquid microextraction (DLLME) procedure coupled to liquid chromatography (LC) with fluorimetric detection was evaluated for the preconcentration and determination of thiamine (vitamin B(1)). Derivatization was carried out by chemical oxidation of thiamine with 5 × 10(-5) M ferricyanide at pH 13 to form fluorescent thiochrome. For DLLME, 0.5 mL of acetonitrile (dispersing solvent) containing 90 μL of tetrachloroethane (extraction solvent) was rapidly injected into 10 mL of sample solution containing the derivatized thiochrome and 24% (w/v) sodium chloride, thereby forming a cloudy solution. Phase separation was carried out by centrifugation, and a volume of 20 μL of the sedimented phase was submitted to LC. The mobile phase was a mixture of a 90% (v/v) 10 mM KH(2)PO(4) (pH 7) solution and 10% (v/v) acetonitrile at 1 mL min(-1). An amide-based stationary phase involving a ligand with amide groups and the endcapping of trimethylsilyl was used. Specificity, linearity, precision, recovery, and sensitivity were satisfactory. Calibration graph was carried out by the standard additions method and was linear between 1 and 10 ng mL(-1). The detection limit was 0.09 ng mL(-1). The selectivity of the method was judged from the absence of interfering peaks at the thiamine elution time for blank chromatograms of unspiked samples. A relative standard deviation of 3.2% was obtained for a standard solution containing thiamine at 5 ng mL(-1). The esters thiamine monophosphate and thiamine pyrophosphate can also be determined by submitting the sample to successive acid and enzymatic treatments. The method was applied to the determination of thiamine in different foods such as beer, brewer's yeast, honey, and baby foods including infant formulas, fermented milk, cereals, and purees. For the analysis of solid samples, a previous extraction step was applied based on an acid hydrolysis with trichloroacetic acid. The reliability of the procedure was

  13. Purification of flavonoids from licorice using an off-line preparative two-dimensional normal-phase liquid chromatography/reversed-phase liquid chromatography method.

    Science.gov (United States)

    Fan, Yunpeng; Fu, Yanhui; Fu, Qing; Cai, Jianfeng; Xin, Huaxia; Dai, Mei; Jin, Yu

    2016-07-01

    An orthogonal (71.9%) off-line preparative two-dimensional normal-phase liquid chromatography/reversed-phase liquid chromatography method coupled with effective sample pretreatment was developed for separation and purification of flavonoids from licorice. Most of the nonflavonoids were firstly removed using a self-made Click TE-Cys (60 μm) solid-phase extraction. In the first dimension, an industrial grade preparative chromatography was employed to purify the crude flavonoids. Click TE-Cys (10 μm) was selected as the stationary phase that provided an excellent separation with high reproducibility. Ethyl acetate/ethanol was selected as the mobile phase owing to their excellent solubility for flavonoids. Flavonoids co-eluted in the first dimension were selected for further purification using reversed-phase liquid chromatography. Multiple compounds could be isolated from one normal-phase fraction and some compounds with bad resolution in one-dimensional liquid chromatography could be prepared in this two-dimensional system owing to the orthogonal separation. Moreover, this two-dimensional liquid chromatography method was beneficial for the preparation of relatively trace flavonoid compounds, which were enriched in the first dimension and further purified in the second dimension. Totally, 24 flavonoid compounds with high purity were obtained. The results demonstrated that the off-line two-dimensional liquid chromatography method was effective for the preparative separation and purification of flavonoids from licorice.

  14. Evaluation between ultrahigh pressure liquid chromatography and high-performance liquid chromatography analytical methods for characterizing natural dyestuffs.

    Science.gov (United States)

    Serrano, Ana; van Bommel, Maarten; Hallett, Jessica

    2013-11-29

    An evaluation was undertaken of ultrahigh pressure liquid chromatography (UHPLC) in comparison to high-performance liquid chromatography (HPLC) for characterizing natural dyes in cultural heritage objects. A new UHPLC method was optimized by testing several analytical parameters adapted from prior UHPLC studies developed in diverse fields of research. Different gradient elution programs were tested on seven UHPLC columns with different dimensions and stationary phase compositions by applying several mobile phases, flow rates, temperatures, and runtimes. The UHPLC method successfully provided more improved data than that achieved by the HPLC method. Indeed, even though carminic acid has shown circa 146% higher resolution with HPLC, UHPLC resulted in an increase of 41-61% resolution and a decrease of 91-422% limit of detection, depending on the dye compound. The optimized method was subsequently assigned to analyse 59 natural reference materials, in which 85 different components were ascribed with different physicochemical properties, in order to create a spectral database for future characterization of dyes in cultural heritage objects. The majority of these reference samples could be successfully distinguished with one single method through the examination of these compounds' retention times and their spectra acquired with a photodiode array detector. These results demonstrate that UHPLC analyses are extremely valuable for the acquisition of more precise chromatographic information concerning natural dyes with complex mixtures of different and/or closely related physicochemical properties, essential for distinguishing similar species of plants and animals used to colour cultural heritage objects.

  15. Comprehensive characterization of Stevia rebaudiana using two-dimensional reversed-phase liquid chromatography/hydrophilic interaction liquid chromatography.

    Science.gov (United States)

    Fu, Qing; Guo, Zhimou; Zhang, Xiuli; Liu, Yanfang; Liang, Xinmiao

    2012-07-01

    Two-dimensional reversed-phase liquid chromatography/hydrophilic interaction liquid chromatography (2D-RPLC/HILIC) system was successfully applied for comprehensive characterization of steviol glycosides from Stevia rebaudiana. The experiments were performed in offline mode using an XCharge C18 column in first dimension and an XAmide column in second dimension. In first dimension, preliminary separation of Stevia aqueous extract was accomplished and 30 fractions were collected. Then fractions 1-20 were selected for further purification and 13 compounds with high purity were obtained in second dimension. Comprehensive characterization of these compounds was completed by determination of their retention time, accurate molecular weight, diagnostic fragmentation ions, and nuclear magnetic resonance spectroscopy. As a result, all nine known steviol glycosides, as well as other four steviol glycosides were fully purified. The result demonstrated that this procedure is an effective approach for the preparative separation and comprehensive characterization of steviol glycosides in Stevia. This 2D-RPLC/HILIC method will be a promising tool for the purification of low-abundance compounds from natural products.

  16. Comparison of liquid chromatography-microchip/mass spectrometry to conventional liquid chromatography-mass spectrometry for the analysis of steroids.

    Science.gov (United States)

    Ahonen, Linda; Keski-Rahkonen, Pekka; Saarelainen, Taija; Paviala, Jenni; Ketola, Raimo A; Auriola, Seppo; Poutanen, Matti; Kostianen, Risto

    2012-04-01

    The feasibility of a microfluidic-based liquid chromatography-electrospray ionization/mass spectrometric system (HPLC-Chip/ESI/MS) was studied and compared to a conventional narrow-bore liquid chromatography-electrospray ionization/mass spectrometric (LC-ESI/MS) system for the analysis of steroids. The limits of detection (LODs) for oxime derivatized steroids, expressed as concentrations, were slightly higher with the HPLC-Chip/MS system (50-300 pM) using an injection volume of 0.5 μL than with the conventional LC-ESI/MS (10-150 pM) using an injection volume of 40 μL. However, when the LODs are expressed as injected amounts, the sensitivity of the HPLC-Chip/MS system was about 50 times higher than with the conventional LC-ESI/MS system. The results indicate that the use of HPLC-Chip/MS system is clearly advantageous only in the analysis of low-volume samples. Both methods showed good linearity and good quantitative and chromatographic repeatability. In addition to the instrument comparisons with oxime derivatized steroids, the feasibility of the HPLC-Chip/MS system in the analysis of non-derivatized and oxime derivatized steroids was compared. The HPLC-Chip/MS method developed for non-derivatized steroids was also applied to the quantitative analysis of 15 mouse plasma samples.

  17. Method transfer from high-pressure liquid chromatography to ultra-high-pressure liquid chromatography. II. Temperature and pressure effects.

    Science.gov (United States)

    Åsberg, Dennis; Samuelsson, Jörgen; Leśko, Marek; Cavazzini, Alberto; Kaczmarski, Krzysztof; Fornstedt, Torgny

    2015-07-03

    The importance of the generated temperature and pressure gradients in ultra-high-pressure liquid chromatography (UHPLC) are investigated and compared to high-pressure liquid chromatography (HPLC). The drug Omeprazole, together with three other model compounds (with different chemical characteristics, namely uncharged, positively and negatively charged) were used. Calculations of the complete temperature profile in the column at UHPLC conditions showed, in our experiments, a temperature difference between the inlet and outlet of 16 °C and a difference of 2 °C between the column center and the wall. Through van't Hoff plots, this information was used to single out the decrease in retention factor (k) solely due to the temperature gradient. The uncharged solute was least affected by temperature with a decrease in k of about 5% while for charged solutes the effect was more pronounced, with k decreases up to 14%. A pressure increase of 500 bar gave roughly 5% increase in k for the uncharged solute, while omeprazole and the other two charged solutes gave about 25, 20 and 15% increases in k, respectively. The stochastic model of chromatography was applied to estimate the dependence of the average number of adsorption/desorption events (n) and the average time spent by a molecule in the stationary phase (τs) on temperature and pressure on peak shape for the tailing, basic solute. Increasing the temperature yielded an increase in n and decrease in τs which resulted in less skew at high temperatures. With increasing pressure, the stochastic modeling gave interesting results for the basic solute showing that the skew of the peak increased with pressure. The conclusion is that pressure effects are more pronounced for both retention and peak shape than the temperature effects for the polar or charged compounds in our study.

  18. Analysis of quality of aviation lubricating oils by means of liquid and gas-liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Kholostova, G.G.; Bakunin, V.N.; Shimonaev, G.S.

    1987-01-01

    The authors examine the basic methodological aspects of chromatographic analysis of the quality of oils for aircraft gas turbine engines, and certain relationships in oil aging that have been established on this basis. A commercial ester (designated PEE) was selected for investigation of pentaerythritol and C/sub 5/-C/sub 9/ synthetic fatty acids (SFA) which serves as the synthetic base stock for a number of aviation oils. The changes in PEE composition upon oxidation, with or without additives, were evaluated by means of gas-liquid chromatography in a Tsvet-100 chromatograph with a flame ionization detector. The results from examination of the original and oxidized PEE samples by means of gas and liquid chromatography are presented.

  19. Purification of amide alkaloids from Piper longum L. using preparative two-dimensional normal-phase liquid chromatography × reversed-phase liquid chromatography.

    Science.gov (United States)

    Li, Kuiyong; Zhu, Wenya; Fu, Qing; Ke, Yanxiong; Jin, Yu; Liang, Xinmiao

    2013-06-07

    A comprehensive off-line two-dimensional liquid chromatography (2D-LC) method coupling normal phase liquid chromatography (NPLC) and reversed phase liquid chromatography (RPLC) was developed for separation and purification of amide alkaloids from Piper longum L. In the first dimension, the crude alkaloid fractions were separated in NPLC mode and 20 fractions were collected. Then fractions 5-20 were selected for further purification in RPLC mode in the second dimension. The purities of RPLC fractions with similar structures were all identified accurately by ultra performance liquid chromatography (UPLC). In total, 28 compounds with high purity were obtained and their structures were comprehensively characterized by electrospray ionization-mass spectrometry (ESI-MS) and nuclear magnetic resonance (NMR) spectroscopy. The results demonstrate that this 2D NPLC × RPLC method with good orthogonality (58.3%) was effective for the preparative separation and purification of amide alkaloids from Piper longum L.

  20. Sheath liquid effects in capillary high-performance liquid chromatography-electrospray mass spectrometry of oligonucleotides.

    Science.gov (United States)

    Huber, C G; Krajete, A

    2000-02-18

    Fused-silica capillary columns of 200 microm inner diameter were packed with micropellicular, octadecylated, 2.3 microm poly(styrene-divinylbenzene) particles and applied to the separation of oligonucleotides by ion-pair reversed-phase high-performance liquid chromatography. Oligonucleotides were eluted at 50 degrees C with gradients of 3-13% acetonitrile in 50 mM triethylammonium bicarbonate. Addition of sheath liquid to the column effluent allowed the detection of oligonucleotides by electrospray ionization mass spectrometry using full-scan data acquisition with a detectability comparable to that obtained with UV detection. The signal-to-noise ratios with different sheath liquids increased in the order isopropanolliquid was found to influence the charge state distribution of oligonucleotides longer than 20 nucleotide units whereas no significant effect was observed with shorter oligonucleotides. Organic acids and bases in the sheath liquid generally deteriorated the signal-to-noise ratios in the chromatograms and mass spectra mainly because of increased background noise. Only a few charge states were observed in the mass spectra of oligonucleotides because of charge state reduction due to the presence of carbonic acid in the eluent. With triethylammonium hydrogencarbonate as chromatographic eluent and acetonitrile as sheath liquid, very few cation adducts of oligonucleotides were observed in the mass spectra. However, the presence of small amounts of monopotassium adducts enabled the calculation of the charge state of multiply charged ions. With acetonitrile as sheath liquid, 710 amol of a 16-mer oligonucleotide were detected using selected ion monitoring data acquisition with a signal-to-noise ratio of 3:1. Finally, capillary ion-pair reversed-phase high-performance liquid chromatography-electrospray ionization mass spectrometry was

  1. Determination of sulfonamides in butter samples by ionic liquid magnetic bar liquid-phase microextraction high-performance liquid chromatography.

    Science.gov (United States)

    Wu, Lijie; Song, Ying; Hu, Mingzhu; Xu, Xu; Zhang, Hanqi; Yu, Aimin; Ma, Qiang; Wang, Ziming

    2015-01-01

    A novel, simple, and environmentally friendly pretreatment method, ionic liquid magnetic bar liquid-phase microextraction, was developed for the determination of sulfonamides in butter samples by high-performance liquid chromatography. The ionic liquid magnetic bar was prepared by inserting a stainless steel wire into the hollow of a hollow fiber and immobilizing ionic liquid in the micropores of the hollow fiber. In the extraction process, the ionic liquid magnetic bars were used to stir the mixture of sample and extraction solvent and enrich the sulfonamides in the mixture. After extraction, the analyte-adsorbed ionic liquid magnetic bars were readily isolated with a magnet from the extraction system. It is notable that the present method was environmentally friendly since water and only several microliters of ionic liquid were used in the whole extraction process. Several parameters affecting the extraction efficiency were investigated and optimized, including the type of ionic liquid, sample-to-extraction solvent ratio, the number of ionic liquid magnetic bars, extraction temperature, extraction time, salt concentration, stirring speed, pH of the extraction solvent, and desorption conditions. The recoveries were in the range of 73.25-103.85 % and the relative standard deviations were lower than 6.84 %. The experiment results indicated that the present method was effective for the extraction of sulfonamides in high-fat content samples.

  2. Recent advances in ultra-high performance liquid chromatography for the analysis of traditional chinese medicine

    Science.gov (United States)

    Traditional Chinese medicines (TCMs) have been widely used for the prevention and treatment of various diseases for thousands of years in China. Ultra Performance Liquid Chromatography (UHPLC) is a relatively new technique offering new possibilities in liquid chromatography. This paper reviews recen...

  3. Determination of Roxarsone in feeds using solid phase extraction and liquid chromatography with ultraviolet detection.

    Science.gov (United States)

    Sapp, R E; Davidson, S

    1993-01-01

    A method is presented for detection and quantitation of Roxarsone in poultry feed by liquid chromatography. The drug is extracted by phosphate buffer and determined by solid phase extraction and reversed-phase liquid chromatography. Recoveries of the sample spikes and fortified field samples agree closely with those obtained by the standard spectrophotometric method.

  4. Applications of nanomaterials in liquid chromatography: opportunities for separation with high efficiency and selectivity.

    Science.gov (United States)

    Zhang, Zhengxiang; Wang, Zhiyong; Liao, Yiping; Liu, Huwei

    2006-08-01

    During recent decades, great efforts have been made to improve the chemical stability, selectivity, and separation efficiency of stationary phases in liquid chromatography. Significant progress has been achieved, especially after the introduction of nanomaterials into separation science. This review covers the applications of nanomaterials playing various roles in liquid chromatography. Future possibilities for developing nanomaterial-based stationary phases are also discussed.

  5. Investigating the Retention Mechanisms of Liquid Chromatography Using Solid-Phase Extraction Cartridges

    Science.gov (United States)

    O'Donnell, Mary E.; Musial, Beata A.; Bretz, Stacey Lowery; Danielson, Neil D.; Ca, Diep

    2009-01-01

    Liquid chromatography (LC) experiments for the undergraduate analytical laboratory course often illustrate the application of reversed-phase LC to solve a separation problem, but rarely compare LC retention mechanisms. In addition, a high-performance liquid chromatography instrument may be beyond what some small colleges can purchase. Solid-phase…

  6. Nano-liquid chromatography in pharmaceutical and biomedical research.

    Science.gov (United States)

    Gama, Mariana Roberto; Collins, Carol H; Bottoli, Carla B G

    2013-08-01

    Miniaturized separation techniques have emerged as environmentally friendly alternatives to available separation methods. Nano-liquid chromatography (nano-LC), microchip devices and nano-capillary electrophoresis are miniaturized methods that minimize reagent consumption and waste generation. Furthermore, the low levels of analytes, especially in biological samples, promote the search for more highly sensitive techniques; coupled to mass spectrometry, nano-LC has great potential to become an indispensable tool for routine analysis of biomolecules. This short review presents the fundamental aspects of nano-LC analytical instrumentation, discussing practical considerations and the primary differences between miniaturized and conventional instrumentation. Some theoretical aspects are discussed to better explain both the potential and the principal limitations of nano-LC. Recent pharmaceutical and biomedical applications of this separation technique are also presented to indicate the satisfactory performance for complex matrices, especially for proteomic analysis, that is obtained with nano-LC.

  7. Biological Fingerprinting of Herbal Samples by Means of Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    Łukasz Cieśla

    2012-01-01

    Full Text Available Biological chromatographic fingerprinting is a relatively new concept in the quality control of herbal samples. Originally it has been developed with the application of HPLC, and recently herbal samples' biological profiles have been obtained by means of thin-layer chromatography (TLC. This paper summarizes the application of liquid chromatographic techniques for the purpose of biological fingerprint analysis (BFA of complex herbal samples. In case of biological TLC fingerprint, which is a relatively novel solution, perspectives of its further development are outlined in more detail. Apart from already published data, some novel results are also shown and briefly discussed. The paper aims at drawing scientists' attention to the unique solutions offered by biological fingerprint construction.

  8. Protein identification using nano liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Negroni, Luc

    2007-01-01

    Tandem mass spectrometry is an efficient technique for the identification of peptides on the basis of their fragmentation pattern (MS/MS scan). It can generate individual spectra for each peptide, thereby creating a powerful tool for protein identification on the basis of peptide characterization. This important advance in automatic data acquisition has allowed an efficient association between liquid chromatography and tandem mass spectrometry, and the use of nanocolumns and nanoelectrospray ionization has dramatically increased the efficiency of this method. Now large sets of peptides can be identified at a femtomole level. At the end of the process, batch processing of the MS/MS spectra produces peptide lists that identify purified proteins or protein mixtures with high confidence.

  9. Microfluidic liquid chromatography system for proteomic applications and biomarker screening.

    Science.gov (United States)

    Lazar, Iulia M; Trisiripisal, Phichet; Sarvaiya, Hetal A

    2006-08-01

    A microfluidic liquid chromatography (LC) system for proteomic investigations that integrates all the necessary components for stand-alone operation, i.e., pump, valve, separation column, and electrospray interface, is described in this paper. The overall size of the LC device is small enough to enable the integration of two fully functional separation systems on a 3 in. x 1 in. glass microchip. A multichannel architecture that uses electroosmotic pumping principles provides the necessary functionality for eluent propulsion and sample valving. The flow rates generated within these chips are fully consistent with the requirements of nano-LC platforms that are routinely used in proteomic applications. The microfluidic device was evaluated for the analysis of a protein digest obtained from the MCF7 breast cancer cell line. The cytosolic protein extract was processed according to a shotgun protocol, and after tryptic digestion and prefractionation using strong cation exchange chromatography (SCX), selected sample subfractions were analyzed with conventional and microfluidic LC platforms. Using similar experimental conditions, the performance of the microchip LC was comparable to that obtained with benchtop instrumentation, providing an overlap of 75% in proteins that were identified by more than two unique peptides. The microfluidic LC analysis of a protein-rich SCX fraction enabled the confident identification of 77 proteins by using conventional data filtering parameters, of 39 proteins with p screening applications.

  10. Gradient chromatofocusing high-performance liquid chromatography. I. Practical aspects.

    Science.gov (United States)

    Liu, Y; Anderson, D J

    1997-02-21

    In this work, a versatile method for generating linear pH gradients using weak anion-exchange HPLC has been developed, which is termed gradient chromatofocusing high-performance liquid chromatography. This method utilizes a linear external pH gradient generated in the mobile phase entering the column (inlet pH gradient), superimposed on an internally-generated pH gradient within the column (column pH gradient), which results from the buffering action of the ion exchanger on the mobile phase and vice versa. The method shows significant advantages over conventional chromatofocusing, including: decreased expense due to the use of common buffer components, ease of adjusting the slope of the pH gradient produced at the outlet of the column (outlet pH gradient) through the manipulation of the inlet pH gradient and the ability of using high concentration buffers in the mobile phase. Chromatography of fibrinogen degradation products was done using gradient chromatofocusing. Bandwidths comparable to conventional chromatofocusing were obtained in the separation of fibrinogen degradation products.

  11. Towards Chip Scale Liquid Chromatography and High Throughput Immunosensing

    Energy Technology Data Exchange (ETDEWEB)

    Ni, Jing [Iowa State Univ., Ames, IA (United States)

    2000-09-21

    This work describes several research projects aimed towards developing new instruments and novel methods for high throughput chemical and biological analysis. Approaches are taken in two directions. The first direction takes advantage of well-established semiconductor fabrication techniques and applies them to miniaturize instruments that are workhorses in analytical laboratories. Specifically, the first part of this work focused on the development of micropumps and microvalves for controlled fluid delivery. The mechanism of these micropumps and microvalves relies on the electrochemically-induced surface tension change at a mercury/electrolyte interface. A miniaturized flow injection analysis device was integrated and flow injection analyses were demonstrated. In the second part of this work, microfluidic chips were also designed, fabricated, and tested. Separations of two fluorescent dyes were demonstrated in microfabricated channels, based on an open-tubular liquid chromatography (OT LC) or an electrochemically-modulated liquid chromatography (EMLC) format. A reduction in instrument size can potentially increase analysis speed, and allow exceedingly small amounts of sample to be analyzed under diverse separation conditions. The second direction explores the surface enhanced Raman spectroscopy (SERS) as a signal transduction method for immunoassay analysis. It takes advantage of the improved detection sensitivity as a result of surface enhancement on colloidal gold, the narrow width of Raman band, and the stability of Raman scattering signals to distinguish several different species simultaneously without exploiting spatially-separated addresses on a biochip. By labeling gold nanoparticles with different Raman reporters in conjunction with different detection antibodies, a simultaneous detection of a dual-analyte immunoassay was demonstrated. Using this scheme for quantitative analysis was also studied and preliminary dose-response curves from an immunoassay of a

  12. Predicting drug penetration across the blood-brain barrier: comparison of micellar liquid chromatography and immobilized artificial membrane liquid chromatography.

    Science.gov (United States)

    De Vrieze, Mike; Lynen, Frédéric; Chen, Kai; Szucs, Roman; Sandra, Pat

    2013-07-01

    Several in vitro methods have been tested for their ability to predict drug penetration across the blood-brain barrier (BBB) into the central nervous system (CNS). In this article, the performance of a variety of micellar liquid chromatographic (MLC) methods and immobilized artificial membrane (IAM) liquid chromatographic approaches were compared for a set of 45 solutes. MLC measurements were performed on a C18 column with sodium dodecyl sulfate (SDS), polyoxyethylene (23) lauryl ether (Brij35), or sodium deoxycholate (SDC) as surfactant in the micellar mobile phase. IAM liquid chromatography measurements were performed with Dulbecco's phosphate-buffered saline (DPBS) and methanol as organic modifier in the mobile phase. The corresponding retention and computed descriptor data for each solute were used for construction of models to predict transport across the blood-brain barrier (log BB). All data were correlated with experimental log BB values and the relative performance of the models was studied. SDS-based models proved most suitable for prediction of log BB values, followed closely by a simplified IAM method, in which it could be observed that extrapolation of retention data to 0% modifier in the mobile phase was unnecessary.

  13. Ultra performance liquid chromatography coupled with electrospray and atmospheric pressure chemical ionization (ESCi)-quadrupole time-of-flight mass spectrometry with novel mass spectrometry(Elevated Energy) (MS(E)) data collection technique: determination and pharmacokinetics, tissue distribution and biliary excretion study of ergone in rat.

    Science.gov (United States)

    Zhao, Ying-Yong; Cheng, Xian-Long; Wei, Feng; Bai, Xu; Lin, Rui-Chao

    2012-07-01

    Ergosta-4,6,8(14),22-tetraen-3-one (ergone) has been proved to have novel antitumor effects on HepG2 cells. The aim of this study was to investigate the pharmacokinetics, tissue distribution, and biliary excretion of ergone in rats following a single oral administration (5, 10, and 20 mg/kg). The levels of ergone in plasma, tissues, and bile were measured by ultra performance liquid chromatography coupled with electrospray and atmospheric pressure chemical ionization (ESCi)-quadrupole time-of-flight mass spectrometry with novel mass spectrometry(Elevated Energy) (MS(E)) data collection technique method. The results show ergone was distributed and eliminated from rat plasma and in non-linear pharmacokinetics from a dose range of 5-20 mg/kg. The ergone was found to distribute widely in the internal organs, with tissue concentrations in order of lungs, spleen, liver, intestine, kidneys, heart, stomach, parorchis, teasticles, and brain. At 12 h after dosing, the tissue concentrations in the organs were markedly decreased. The lungs, spleen, and liver were the dominant organs with high tissue concentrations that might be the primary sites for metabolism and elimination of ergone. Total recoveries of ergone within 24 h in bile were 34.14%.

  14. Analysis of Short Chain Chlorinated Paraffins in Leather by Liquid Chromatography-Atmosphere Pressure Ionization Mass Spectrometry%皮革中短链氯化石蜡的液相色谱-大气压化学电离质谱分析

    Institute of Scientific and Technical Information of China (English)

    马贺伟

    2012-01-01

    Short - chain chlorinated paraffins ( SCCPs) in leather were analyzed by liquid chromatography combined atmosphere pressure ionization mass spectrometry ( LC - APCI/MS). The results demonstrated that multi - clusters of chloride adduct ions were contained in the mass spectrum and the response factors were dependent on the degree of chlorination. Selective Ion Monitoring (SIM) mode could reduce the interferences of medium - chain chlorinated paraffins (MCCPs). However, the significant interferences were found when leather samples were tested due to the expressive complexity of the matrix in leather, which easily resulted in FALSE positives.%采用液相色谱-大气压化学电离源质谱(LC-MS/APCI)对皮革中短链氯化石蜡(SCCPs)进行分析.结果表明,SCCPs的质谱图包含了多簇离子碎片峰,其响应值表现出对氯含量的依赖性;采用选择监测离子模式可有效降低中链氯化石蜡(MCCPs)的干扰,但实际皮革样品基质的多样性及复杂性,极易造成检测结果的假阳性.

  15. Salting-out assisted liquid-liquid extraction coupled to dispersive liquid-liquid microextraction for the determination of chlorophenols in wine by high-performance liquid chromatography.

    Science.gov (United States)

    Fan, Yingying; Hu, Shibin; Liu, Shuhui

    2014-12-01

    A novel procedure of sample preparation combined with high-performance liquid chromatography with diode array detection is introduced for the analysis of highly chlorinated phenols (trichlorophenols, tetrachlorophenols, and pentachlorophenol) in wine. The main features of the proposed method are (i) low-toxicity diethyl carbonate as extraction solvent to selectively extract the analytes without matrix effect, (ii) the combination of salting-out assisted liquid-liquid extraction and dispersive liquid-liquid microextraction to achieve an enrichment factor of 334-361, and (iii) the extract is analyzed by high-performance liquid chromatography to avoid derivatization. Under the optimum conditions, correlation coefficients (r) were >0.997 for calibration curves in the range 1-80 ng/mL, detection limits and quantification limits ranged from 0.19 to 0.67 and 0.63 to 2.23 ng/mL, respectively, and relative standard deviation was wines, with recovery rates in the range 82-104%. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Discrimination of eight chloramphenicol isomers by liquid chromatography tandem mass spectrometry in order to investigate the natural occurence of chloramphenicol

    NARCIS (Netherlands)

    Berendsen, B.J.A.; Zuidema, T.; Jong, de J.; Stolker, A.A.M.; Nielen, M.W.F.

    2011-01-01

    This paper describes the discrimination of eight different isomers of chloramphenicol (CAP), an antibiotic banned for use in food producing animals, by reversed phase and chiral liquid chromatography in combination with tandem mass spectrometric detection. Previously, by liquid chromatography couple

  17. Pressurized liquid extraction followed by liquid chromatography with tandem mass spectrometry to determine pharmaceuticals in mussels.

    Science.gov (United States)

    Núñez, Mireia; Borrull, Francesc; Pocurull, Eva; Fontanals, Núria

    2016-02-01

    An analytical method based on pressurized liquid extraction and solid-phase extraction with a mixed-mode Oasis(®) MAX sorbent as cleanup, followed by liquid chromatography with electrospray ionization and tandem mass spectrometry was developed and validated for the determination of seven widely used pharmaceuticals in mussel species. The optimization of the pressurized liquid extraction and the solid-phase extraction parameters is described. The method provided extraction recoveries ranging from 61 to 90%, and limits of detection ranging from 2 to 50 ng/g (dry weight). The repeatability and reproducibility of the method, expressed as relative standard deviation, were lower than 15 and 19%, respectively. The method was successfully applied to the analysis of mussel samples from different locations. The analyses showed that salicylic acid was present in mussels at concentrations up to 177 ng/g (dry weight).

  18. Three dimensional liquid chromatography coupling ion exchange chromatography/hydrophobic interaction chromatography/reverse phase chromatography for effective protein separation in top-down proteomics.

    Science.gov (United States)

    Valeja, Santosh G; Xiu, Lichen; Gregorich, Zachery R; Guner, Huseyin; Jin, Song; Ge, Ying

    2015-01-01

    To address the complexity of the proteome in mass spectrometry (MS)-based top-down proteomics, multidimensional liquid chromatography (MDLC) strategies that can effectively separate proteins with high resolution and automation are highly desirable. Although various MDLC methods that can effectively separate peptides from protein digests exist, very few MDLC strategies, primarily consisting of 2DLC, are available for intact protein separation, which is insufficient to address the complexity of the proteome. We recently demonstrated that hydrophobic interaction chromatography (HIC) utilizing a MS-compatible salt can provide high resolution separation of intact proteins for top-down proteomics. Herein, we have developed a novel 3DLC strategy by coupling HIC with ion exchange chromatography (IEC) and reverse phase chromatography (RPC) for intact protein separation. We demonstrated that a 3D (IEC-HIC-RPC) approach greatly outperformed the conventional 2D IEC-RPC approach. For the same IEC fraction (out of 35 fractions) from a crude HEK 293 cell lysate, a total of 640 proteins were identified in the 3D approach (corresponding to 201 nonredundant proteins) as compared to 47 in the 2D approach, whereas simply prolonging the gradients in RPC in the 2D approach only led to minimal improvement in protein separation and identifications. Therefore, this novel 3DLC method has great potential for effective separation of intact proteins to achieve deep proteome coverage in top-down proteomics.

  19. A Method for the Quantitation of Trace Levels of Dimethyl Sulfoxide in Urine by High Performance Liquid Chromatography

    Science.gov (United States)

    1989-05-01

    HIGH PERFORMANCE LIQUID CHROMATOGRAPHY by...for the sample cleanup and concentration, followed by separation by reversed phase high performance liquid chromatography . EXPERIMENTAL Materials...DIMETHYL SULFOXIDE IN URINE BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY 4. AUTHORS (Last name, first name, middle initial. If military, show rank, e.g.

  20. Determination of Dimethyl Sulfoxide (DMSO), Ethanol (ETOH), Formamide (F) and Glycerol/Formal (GF) by High Performance Liquid Chromatography (HPLC)

    Science.gov (United States)

    1989-01-30

    HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC...Classification) (U) Determination of Dimethyl Sulfoxide (DMSO), Ethanol, (ETOH), Formamide (F), and Glycerol/ Formal (GF) by High Performance Liquid Chromatography (HPLC...and 5). High performance liquid chromatography (HPLC) was the analytical method of choice for analyzing DMSO, ethanol, formamide and

  1. Determination of 5-Bromo-2’-Deoxyuridine (BrdU) in Well Water by High Performance Liquid Chromatography (HPLC)

    Science.gov (United States)

    1992-09-01

    HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC...Securrty Classification) Determination of 5-Bromo-2’-Deoxyuridine (BrdU) in Well Water by High Performance Liquid Chromatography (hPLC) 12. PERSONAL...PLOT OF BrdU STABILITY VERSUS TIME ....................... 10 ii DETERMINATION OF 5-BROMO-2’-DEOXY-URIDINE (BrdU) IN WELL WATER BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

  2. Determination of Organic Pollutants in Small Samples of Groundwaters by Liquid-Liquid Extraction and Capillary Gas Chromatography

    DEFF Research Database (Denmark)

    Harrison, I.; Leader, R.U.; Higgo, J.J.W.;

    1994-01-01

    A method is presented for the determination of 22 organic compounds in polluted groundwaters. The method includes liquid-liquid extraction of the base/neutral organics from small, alkaline groundwater samples, followed by derivatisation and liquid-liquid extraction of phenolic compounds after...... neutralisation. The extracts were analysed by capillary gas chromatography. Dual detection by flame Ionisation and electron capture was used to reduce analysis time....

  3. Determination of telmisartan in human blood plasma: Part II: Liquid chromatography-tandem mass spectrometry method development, comparison to immunoassay and pharmacokinetic study

    NARCIS (Netherlands)

    Hempen, C.M.; Gläsle-Schwarz, Liane; Kunz, Ulrich; Karst, U.

    2006-01-01

    A new liquid chromatography/atmospheric pressure chemical ionization-tandem mass spectrometry (LC/APCI-MS/MS) method with on-line sample clean-up for the determination of telmisartan in human blood plasma is presented. This technique is compared to a previously introduced enzyme-linked immunosorbent

  4. Application of Genetic Algorithms for Parameter Estimation in Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    Orestes Llanes Santiago

    2011-11-01

    Full Text Available Normal 0 21 false false false ES X-NONE X-NONE /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Tabla normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;} In chromatography, complex inverse problems related to the parameters estimation and process optimization are presented. Metaheuristics methods are known as general purpose approximated algorithms which seek and hopefully find good solutions at a reasonable computational cost. These methods are iterative process to perform a robust search of a solution space. Genetic algorithms are optimization techniques based on the principles of genetics and natural selection. They have demonstrated very good performance as global optimizers in many types of applications, including inverse problems. In this work, the effectiveness of genetic algorithms is investigated to estimate parameters in liquid chromatography.

  5. Determination of carbocysteine in human plasma by liquid chromatography/tandem mass spectrometry employing precolumn derivatization.

    Science.gov (United States)

    Chen, Xiaoyan; Zhong, Dafang; Han, Ying; Xie, Zhiyong

    2003-01-01

    A sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed to determine carbocysteine in human plasma using 2-pyridylacetic acid as the internal standard (IS). The method employed derivatization with 10 M hydrochloric acid/methanol, which significantly improved the ionization efficiency of carbocysteine. After methanol-induced protein precipitation of plasma samples, carbocysteine and the IS were derivatized and subjected to LC/MS/MS analysis using atmospheric pressure chemical ionization. The method has a lower limit of quantitation of 20 ng/mL for a 0.2-mL plasma aliquot. The intra- and inter-day precision (RSD), calculated from quality control (QC) samples, was less than 7%. The accuracy, determined using QC samples, was within +/- 1%. The method offered increased sensitivity, selectivity and speed of analysis over existing methods. The method was utilized to support clinical pharmacokinetic studies of carbocysteine in volunteers following oral administration. Copyright 2002 John Wiley & Sons, Ltd.

  6. Current Applications of Liquid Chromatography/Mass Spectrometry in Pharmaceutical Discovery After a Decade of Innovation

    Science.gov (United States)

    Ackermann, Bradley L.; Berna, Michael J.; Eckstein, James A.; Ott, Lee W.; Chaudhary, Ajai K.

    2008-07-01

    Current drug discovery involves a highly iterative process pertaining to three core disciplines: biology, chemistry, and drug disposition. For most pharmaceutical companies the path to a drug candidate comprises similar stages: target identification, biological screening, lead generation, lead optimization, and candidate selection. Over the past decade, the overall efficiency of drug discovery has been greatly improved by a single instrumental technique, liquid chromatography/mass spectrometry (LC/MS). Transformed by the commercial introduction of the atmospheric pressure ionization interface in the mid-1990s, LC/MS has expanded into almost every area of drug discovery. In many cases, drug discovery workflow has been changed owing to vastly improved efficiency. This review examines recent trends for these three core disciplines and presents seminal examples where LC/MS has altered the current approach to drug discovery.

  7. Extensive database of liquid phase diffusion coefficients of some frequently used test molecules in reversed-phase liquid chromatography and hydrophilic interaction liquid chromatography.

    Science.gov (United States)

    Song, Huiying; Vanderheyden, Yoachim; Adams, Erwin; Desmet, Gert; Cabooter, Deirdre

    2016-07-15

    Diffusion plays an important role in all aspects of band broadening in chromatography. An accurate knowledge of molecular diffusion coefficients in different mobile phases is therefore crucial in fundamental column performance studies. Correlations available in literature, such as the Wilke-Chang equation, can provide good approximations of molecular diffusion under reversed-phase conditions. However, these correlations have been demonstrated to be less accurate for mobile phases containing a large percentage of acetonitrile, as is the case in hydrophilic interaction liquid chromatography. A database of experimentally measured molecular diffusion coefficients of some 45 polar and apolar compounds that are frequently used as test molecules under hydrophilic interaction liquid chromatography and reversed-phase conditions is therefore presented. Special attention is given to diffusion coefficients of polar compounds obtained in large percentages of acetonitrile (>90%). The effect of the buffer concentration (5-10mM ammonium acetate) on the obtained diffusion coefficients is investigated and is demonstrated to mainly influence the molecular diffusion of charged molecules. Diffusion coefficients are measured using the Taylor-Aris method and hence deduced from the peak broadening of a solute when flowing through a long open tube. The validity of the set-up employed for the measurement of the diffusion coefficients is demonstrated by ruling out the occurrence of longitudinal diffusion, secondary flow interactions and extra-column effects, while it is also shown that radial equilibration in the 15m long capillary is effective.

  8. An approach based on ultrahigh performance liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry allowing the quantification of both individual phytosteryl and phytostanyl fatty acid esters in complex mixtures.

    Science.gov (United States)

    Scholz, Birgit; Menzel, Nicole; Lander, Vera; Engel, Karl-Heinz

    2016-01-15

    A method for the analysis of both individual phytosteryl and phytostanyl fatty acid esters in complex mixtures was established. The approach was based on a previously not described combination of three elements: (i) the formation of [M-FA+H](+) fragment ions via APCI (atmospheric pressure chemical ionization), (ii) a highly efficient UHPLC-based separation on a 1.7 μ C8 column, previously established for phytostanyl fatty acid esters, allowing the distinction of individual fatty acid esters sharing the same sterol/stanol nucleus and of isotope peaks of phytosteryl fatty acid esters and corresponding phytostanyl fatty acid esters based on these [M-FA+H](+) fragment ions, and (iii) the adjustment of the APCI conditions allowing the differential APCI-MS-SIM (single ion monitoring) detection of phytostanyl esters of linoleic and linolenic acid based on their distinct formation of a [M+H](+) ion. The usefulness of the methodology was demonstrated by the analysis of a commercially available enriched margarine. Two runs per sample allowed the quantification of 35 target analytes; the total amounts of esters were between 124.7 and 125.3g/kg, being in good agreement with the labelled 125 g/kg. Validation data were elaborated for 35 individual fatty acid esters of sitosterol, campesterol, brassicasterol, stigmasterol, sitostanol and campestanol. Recovery rates ranged from 95 to 106%; the coefficients of variation were consistently quantification of both individual phytosteryl and phytostanyl fatty acid esters and thus closes an analytical gap related to this class of health-relevant food constituents.

  9. HIGH PERFORMANCE LIQUID CHROMATOGRAPHY DETECTORS – A REVIEW

    Directory of Open Access Journals (Sweden)

    Kaushal Ramni

    2011-05-01

    Full Text Available HPLC is the most versatile and widely used elution chromatography. The technique is used to resolve and determine species in a variety of organic, inorganic, biological, ionic and polymeric materials. Detector is the heart of an instrument and efficiency of system is dependent upon detecting techniques. Many types of HPLC detectors exist, each of which has some valuable performance feature such as refractive index detector, ultraviolet detector, fluorescent detector, electrochemical detector, electric conductivity detector, liquid light scattering detector, evaporative light scattering detector. Due to strong requirement for improvements in sensitivity, selectivity and other performance characteristics of the detector recent developments in conventional techniques and some other new technologies have been adopted such as laser light scattering detector, charged aerosol detector, nano quantity aerosol detector, chiral detector and pulsed amperometric detector. These detectors provide accurate concentration analysis, excellent sensitivity, wide dynamic range, consistent response and broad applicability of the drug components. Working of these detectors involve different principles such as optical techniques, aerosol based techniques, refractive methods, light scattering principle, amperometric and fluorescence. The present review enlightens both conventional and advanced techniques and compares their capabilities of analyzing drug components and need for new techniques for better and wide range of applicability.

  10. Determination of saffron quality by high-performance liquid chromatography.

    Science.gov (United States)

    Valle García-Rodríguez, M; Serrano-Díaz, Jéssica; Tarantilis, Petros A; López-Córcoles, Horacio; Carmona, Manuel; Alonso, Gonzalo L

    2014-08-13

    The aim of this work was to propose a high-performance liquid chromatography with diode array detection (HPLC-DAD) method for determining the three main compounds responsible for determining the quality of saffron (crocetin esters, picrocrocin, and safranal) by preparing an aqueous extract according to the ISO 3632 standard to solve the difficulty that this standard has for aroma and taste determination by ultraviolet-visible spectroscopy. Toward this aim, laboratory-isolated picrocrocin, a safranal standard with a purity of ≥ 88%, trans-crocetin di(β-D-gentiobiosyl) ester (trans-4-GG) and trans-crocetin (β-D-glucosyl)-(β-D-gentiobiosyl) ester (trans-3-Gg) standards, both with a purity of ≥ 99%, and 50 different saffron spice samples from Italy, Iran, Greece, and Spain were used in the intralaboratory validation of the HPLC method. The analytical method proposed was adequate in terms of linearity, selectivity, sensitivity, and accuracy for determining the three foremost parameters that define the quality of saffron using only a saffron solution prepared according to the ISO 3632 standard.

  11. Molecular simulation studies of reversed-phase liquid chromatography.

    Science.gov (United States)

    Lindsey, Rebecca K; Rafferty, Jake L; Eggimann, Becky L; Siepmann, J Ilja; Schure, Mark R

    2013-04-26

    Over the past 20 years, molecular simulation methods have been applied to the modeling of reversed-phase liquid chromatography (RPLC). The purpose of these simulations was to provide a molecular-level understanding of: (i) the structure and dynamics of the bonded phase and its interface with the mobile phase, (ii) the interactions of analytes with the bonded phase, and (iii) the retention mechanism for different analytes. However, the investigation of chromatographic systems poses significant challenges for simulations with respect to the accuracy of the molecular mechanics force fields and the efficiency of the sampling algorithms. This review discusses a number of aspects concerning molecular simulation studies of RPLC systems including the historical development of the subject, the background needed to understand the two prevalent techniques, molecular dynamics (MD) and Monte Carlo (MC) methods, and the wealth of insight provided by these simulations. Examples from the literature employing MD approaches and from the authors' laboratory using MC methods are discussed. The former can provide information on chain dynamics and transport properties, whereas the latter techniques are uniquely suited for the investigation of phase and sorption equilibria that underly RPLC retention, and both can be used to elucidate the bonded-chain conformations and solvent distributions. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. Analysis of Cordyceps by multi-column liquid chromatography

    Directory of Open Access Journals (Sweden)

    Zhengming Qian

    2017-03-01

    Full Text Available Cordyceps is a famous traditional Chinese medicine (TCM that has been used in China for hundreds of years. In the present study a multi-column liquid chromatography (MC-LC system was developed for the qualitative analysis of macromolecules and micromolecules in Cordyceps. The MC-LC system includes a size exclusion pre-column, a size exclusion column (SEC and a reversed phase column (RP which were controlled by column-switching valves. The sample was separated by the size exclusion pre-column into two fractions (macromolecules and micromolecules. These fractions were further separated on SEC and RP columns, respectively. A diode array detector (DAD and a mass spectrometer (MS were used to detect the components. This MC-LC method was utilized for analysis of Cordyceps samples. Two macromolecular peaks and 15 micromolecular peaks were found in Cordyceps, and 11 of the micromolecular peaks were identified as adenosine-5′-monophosphate (AMP, phenylalanine, uridine, hypoxanthine, inosine, guanine, guanosine, deoxyadenosine-5′-monophosphate (dAMP, adenosine, adenine and cordycepin (or its isomer. This method is useful for quality control of Cordyceps.

  13. Analysis of Cordyceps by multi-column liquid chromatography.

    Science.gov (United States)

    Qian, Zhengming; Li, Shaoping

    2017-03-01

    Cordyceps is a famous traditional Chinese medicine (TCM) that has been used in China for hundreds of years. In the present study a multi-column liquid chromatography (MC-LC) system was developed for the qualitative analysis of macromolecules and micromolecules in Cordyceps. The MC-LC system includes a size exclusion pre-column, a size exclusion column (SEC) and a reversed phase column (RP) which were controlled by column-switching valves. The sample was separated by the size exclusion pre-column into two fractions (macromolecules and micromolecules). These fractions were further separated on SEC and RP columns, respectively. A diode array detector (DAD) and a mass spectrometer (MS) were used to detect the components. This MC-LC method was utilized for analysis of Cordyceps samples. Two macromolecular peaks and 15 micromolecular peaks were found in Cordyceps, and 11 of the micromolecular peaks were identified as adenosine-5'-monophosphate (AMP), phenylalanine, uridine, hypoxanthine, inosine, guanine, guanosine, deoxyadenosine-5'-monophosphate (dAMP), adenosine, adenine and cordycepin (or its isomer). This method is useful for quality control of Cordyceps.

  14. Electrochemical flow cell, particularly use with liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Matson, W.R.

    1983-11-08

    An amperometric cell modified for high pressure operation is described. The cell is a flow-through type cell defining a flow path and has at least one active testing electrode, at least one reference electrode and at least one counter electrode operatively disposed and electrically insulated from one another within the cell flow path. In a preferred embodiment the flow cell is encapsulated within a high impact, chemically resistant, chemically insulating material, and has a pair of high pressure resistance fittings communicating with the flow path and extending in part beyond the encapsulation. The cell has particular utility for use with a liquid chromatography separation and when placed in line upstream of sample injection, will remove selected electroactive components in the carrier fluid and thereby reduce background level of contaminents reaching the column and eluting from the column. The cell may also be placed in line following sample injection whereby it may be employed to electrochemically modify selected materials in the mobile phase whereby to change their chromatographic characteristics.

  15. Determination of Glimepiride in Human Plasma by Liquid Chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ho Hyun; Lee, Hee Joo [Seoul Clinical Laboratories, Seoul (Korea, Republic of); Chang, Kyu Young [Korean Biochip Society, Seoul (Korea, Republic of); Han, Sang Beom [ChungAng University, Seoul (Korea, Republic of)

    2004-01-15

    A sensitive method for quantitation of glimepiride in human plasma has been established using liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI/MS/MS). Glipizide was used as an internal standard. Glimepiride and internal standard in plasma sample was extracted using diethyl etherethyl acetate (1 : 1). A centrifuged upper layer was then evaporated and reconstituted with the mobile phase of acetonitrile-5 mM ammonium acetate (60:40, pH 3.0). The reconstituted samples were injected into a C{sub 18} reversed-phase column. Using MS/MS in the multiple reaction monitoring (MRM) mode, glimepiride and glipizide were detected without severe interference from human plasma matrix. Glimepiride produced a protonated precursor ion ([M+H]{sup +}) at m/z 491 and a corresponding product ion at m/z 352. And the internal standard produced a protonated precursor ion ([M+H]{sup +}) at m/z 446 and a corresponding product ion at m/z 321. Detection of glimepiride in human plasma by the LC-ESI/MS/MS method was accurate and precise with a quantitation limit of 0.1 ng/mL. The validation, reproducibility, stability, and recovery of the method were evaluated. The method has been successfully applied to pharmacokinetic studies of glimepiride in human plasma

  16. Gradient chromatofocusing high-performance liquid chromatography. II. Theoretical aspects.

    Science.gov (United States)

    Liu, Y; Anderson, D J

    1997-02-21

    This article is Part II of a series describing a newly-developed gradient chromatofocusing high-performance liquid chromatography (HPLC) technique. Theoretical aspects of the technique are discussed. In gradient chromatofocusing, the column pH gradient with respect to column distance can be varied without necessarily affecting the outlet pH gradient with respect to time. Factors influencing the value of the slope of the column pH gradient are identified through derived equations and a computer simulation model. A newly-identified parameter is introduced, column travel time, which can be uniquely varied in gradient chromatofocusing. Experiments show increased conversion of fibrinogen to denatured forms with increased column travel time. Another unique aspect of gradient chromatofocusing is that the mobile phase buffer concentration can be manipulated without necessarily affecting the outlet pH gradient slope, giving the technique expanded versatility for optimizing the separation. In the present work, the pIapparent for fibrinogen is found to increase with increased mobile phase buffer concentration.

  17. Chromatographic analysis of olopatadine in hydrophilic interaction liquid chromatography.

    Science.gov (United States)

    Maksić, Jelena; Jovanović, Marko; Rakić, Tijana; Popović, Igor; Ivanović, Darko; Jančić-Stojanović, Biljana

    2015-01-01

    In this paper, chromatographic analysis of active substance olopatadine hydrochloride, which is used in eye drops as antihistaminic agent, and its impurity E isomer by hydrophilic interaction liquid chromatography (HILIC) and application of design of experiments (DoE) methodology are presented. In addition, benzalkonium chloride is very often used as a preservative in eye drops. Therefore, the evaluation of its chromatographic behavior in HILIC was carried out as well. In order to estimate chromatographic behavior and set optimal chromatographic conditions, DoE methodology was applied. After the selection of important chromatographic factors, Box-Behnken design was utilized, and on the basis of the obtained models factor effects were examined. Then, multi-objective robust optimization is performed aiming to obtain chromatographic conditions that comply with several quality criteria simultaneously: adequate and robust separation of critical peak pair and maximum retention of the first eluting peak. The optimal conditions are identified by using grid point search methodology. The experimental verification confirmed the adequacy of the defined optimal conditions. Finally, under optimal chromatographic conditions, the method was validated and applicability of the proposed method was confirmed.

  18. Separation of microcystins and nodularins by ultra performance liquid chromatography.

    Science.gov (United States)

    Spoof, Lisa; Neffling, Milla-Riina; Meriluoto, Jussi

    2009-11-15

    Four ultra performance liquid chromatography (UPLC) columns with different reversed-phase characteristics were tested in the chromatographic separation of 10 microcystins and three nodularins, cyanobacterial peptide toxins. The columns had been designed by the manufacturer to withstand the ultra-high pressure generated by sub-2microm stationary phase particles and the Waters ACQUITY UPLC system in ultra-fast separations. The gradient mobile phase consisted of water and acetonitrile, both acidified with trifluoroacetic acid, with three gradient rise times: 1, 1.5 and 2min. The UV detection of the toxins was performed by a photodiode array detector. The chromatographic performance was evaluated both visually and by calculating chromatographic parameters such as capacity factor, resolution, peak width at half height, selectivity and peak asymmetry. The best chromatographic performance as judged by visual inspection was given by the ACQUITY BEH Shield RP18 and ACQUITY BEH Phenyl columns. The BEH Shield RP18 column showed excellent selectivity and resolution of chosen peak pairs considered as critical. A further advantage of the UPLC system was the high sample throughput with a total analysis time of 3.12min (injection-to-injection) equalling to 461 separations per 24h.

  19. Simultaneous determination of cyclodol and diprazin by thin layer chromatography and high performance liquid chromatography.

    Science.gov (United States)

    Makharadze, R; Adeishvili, L; Chelidze, T; Imnadze, N; Nizharadze, N

    2009-11-01

    Ciklodol (trihexyphenidil)--the central and peripheral m-cholinoblocker is currently used with other antipsychotic drugs such as phenotiazines and tricycle antidepressants. For the purpose of simultaneous determination of ciklodol and diprazine, were selected two methods of analysis: Thin Layer Chromatography (TLC) and High Performance Liquid Chromatography (HPLC). During development of TLC method was studied the 10 visualizing system and 24 mobile systems. For individual or simultaneous determination of ciklodol and diprazine were recommended the following solvents' systems: 1. Toluene-acetone-ethanole-25%NH(4)OH (45:45: 7.5:2.5), 2. Hexane-ethyl acetate (15:5), 3. Chloroform-heptene-25%NH(4)OH (16:3:3), 4. Ethylacetate-hexane (10:10), 5. Acetonitrile-metanol (10:10) and 6.Heptene-chloroform-ethanol-25% NH(4)OH (5:10:3:1). As visualizing systems were chosen: Iodine vapors, blacklight (UV254) and reagent of FNP. Reagent of FNP gives colored spot just with diprazine and it is also could be used for separation of both objects in simultaneous analysis. Developed HPLC method of simultaneous determination of ciklodol and diprazine: like mobile phase is recommended: Acetonitril- 0.05M KH(2)PO4 (55:45) (v/v) +H(3)PO(4) (pH3.5), column EC250 x 4.6mm, with solid phase Nucleosil, flow rate 1ml/min, sample volume 40 microl. In given conditions, the retention time of ciklodol is 6.005min and diprazine 7.227min. Developed method of simultaneous determination and separation of ciklodol and diprazine in respective mixtures could be successfully applied as in the pharmaceutical, as well in the chemical-toxicological laboratories.

  20. Investigation of the ionization mechanism of polycyclic aromatic hydrocarbons using an ethanol/bromobenzene/chlorobenzene/anisole mixture as a dopant in liquid chromatography/atmospheric pressure photoionization mass spectrometry

    KAUST Repository

    Amad, Maan H.

    2012-09-23

    RATIONALE An ethanol-based multicomponent dopant consisting of ethanol/chlorobenzene/bromobenzene/anisole (98.975:0.1:0.9:0.025, v/v/v/v) has been used as a dopant for atmospheric pressure photoionization (APPI) of polycyclic aromatic hydrocarbons (PAHs). In this study the mechanism of ionization of PAHs assisted by the ethanol-based multicomponent dopant is investigated. METHODS The reactant background cluster ions of the ethanol-based multicomponent dopant observed in the positive ion APPI were studied. These studies were performed to investigate the mechanism behind the generation of a molecular radical cation (M +•) for PAHs by APPI assisted by the ethanol-based multicomponent dopant. Full scan and MS/MS analyses were conducted using an LTQ Orbitrap mass spectrometer. The effect of acidification of the mobile phase on the dopant cluster ion formation was also investigated. RESULTS With the ethanol-based multicomponent dopant, a single type of molecular radical cation M +• was observed for the studied PAHs. The characteristic ion signal of the multicomponent dopant mixture consisted of mainly anisole photoions at m/z 108.05697 and its adduct ions at m/z 124.05188 and 164.07061. The anisole ion response at m/z 108.05697 was stable in the presence of acetonitrile, methanol, water and 0.1% formic acid mobile phase composition. CONCLUSIONS The abundance formation of anisole photoions shows the universality of this multicomponent dopant in ionizing compounds with ionization energy ranging from 7.1-8.2 eV. Since the ionization energy of anisole is 8.2 eV and is lower than those of chlorobenzene (9.07 eV) and bromobenzene (9.0 eV), the mechanism of formation of anisole photoions even with its very minute amounts was not only governed by its photoionization by the krypton lamp photon energy (10.0 eV and 10.6 eV), but also by charge transfer from bromobenzene and chlorobenzene radical cations. PAH molecules were mainly ionized by charge transfer reaction from

  1. High-performance liquid chromatography analysis methods developed for quantifying enzymatic esterification of flavonoids in ionic liquids

    DEFF Research Database (Denmark)

    Lue, Bena-Marie; Guo, Zheng; Xu, X.B.

    2008-01-01

    Methods using reversed-phase high-performance liquid chromatography (RP-HPLC) with ELSD were investigated to quantify enzymatic reactions of flavonoids with fatty acids in the presence of diverse room temperature ionic liquids (RTILs). A buffered salt (preferably triethylamine-acetate) was found ...

  2. Simultaneous analysis for water- and fat-soluble vitamins by a novel single chromatography technique unifying supercritical fluid chromatography and liquid chromatography.

    Science.gov (United States)

    Taguchi, Kaori; Fukusaki, Eiichiro; Bamba, Takeshi

    2014-10-03

    Chromatography techniques usually use a single state in the mobile phase, such as liquid, gas, or supercritical fluid. Chromatographers manage one of these techniques for their purpose but are sometimes required to use multiple methods, or even worse, multiple techniques when the target compounds have a wide range of chemical properties. To overcome this challenge, we developed a single method covering a diverse compound range by means of a "unified" chromatography which completely bridges supercritical fluid chromatography and liquid chromatography. In our method, the phase state was continuously changed in the following order; supercritical, subcritical and liquid. Moreover, the gradient of the mobile phase starting at almost 100% CO2 was replaced with 100% methanol at the end completely. As a result, this approach achieved further extension of the polarity range of the mobile phase in a single run, and successfully enabled the simultaneous analysis of fat- and water-soluble vitamins with a wide logP range of -2.11 to 10.12. Furthermore, the 17 vitamins were exceptionally separated in 4min. Our results indicated that the use of dense CO2 and the replacement of CO2 by methanol are practical approaches in unified chromatography covering diverse compounds. Additionally, this is a first report to apply the novel approach to unified chromatography, and can open another door for diverse compound analysis in a single chromatographic technique with single injection, single column and single system.

  3. A simple liquid extraction protocol for overcoming the ion suppression of triacylglycerols by phospholipids in liquid chromatography mass spectrometry studies.

    Science.gov (United States)

    Araujo, Pedro; Tilahun, Ephrem; Breivik, Joar Fjørtoft; Abdulkader, Bashir M; Frøyland, Livar; Zeng, Yingxu

    2016-02-01

    It is well-known that triacylglycerol (TAG) ions are suppressed by phospholipid (PL) ions in regiospecific analysis of TAG by mass spectrometry (MS). Hence, it is essential to remove the PL during sample preparation prior to MS analysis. The present article proposes a cost-effective liquid-liquid extraction (LLE) method to remove PL from TAG in different kinds of biological samples by using methanol, hexane and water. High performance thin layer chromatography confirmed the lack of PL in krill oil and salmon liver samples, submitted to the proposed LLE protocol, and liquid chromatography tandem MS confirmed that the identified TAG ions were highly enhanced after implementing the LLE procedure.

  4. Electrochemically modulated liquid chromatography: Theoretical investigations and applications from the perspectives of chromatography and interfacial electrochemistry

    Energy Technology Data Exchange (ETDEWEB)

    Keller, David W.

    2005-05-01

    Electrochemically modulated liquid chromatography (EMLC) employs a conductive material as both a stationary phase for chromatographic separations and as a working electrode for performing electrochemistry experiments. This dual functionality gives EMLC the capacity to manipulate chromatographic separations by changing the potential applied (E{sub app}) to the stationary phase with respect to an external reference. The ability to monitor retention as a function of E{sub app} provides a means to chromatographically monitor electrosorption processes at solid-liquid interfaces. In this dissertation, the retention mechanism for EMLC is examined from the perspective of electrical double layer theory and interfacial thermodynamics. From the chromatographic data, it is possible to determine the interfacial excess ({Lambda}) of a solute and changes in interfacial tension (d{gamma}) as a function of both E{sub app} and the supporting electrolyte concentration. Taken together, these two experimentally manipulated parameters can be examined within the context of the Gibbs adsorption equation to delineate the contribution of a variety of interfacial properties, including the charge of solute on the stationary phase and the potential of zero charge (PZC), to the mechanism behind EMLC-based retention. The chromatographic probing of interfacial phenomena is complemented by electroanalytical experiments that exploit the ability to monitor the electronic current flowing through an EMLC column. Cyclic voltammetry and chronoamperometry of an EMLC column are used to determine the electronic performance characteristics of an EMLC column. An electrochemical flow injection analysis of a column is provided in which the current required to maintain a constant E{sub app} is monitored and provides a way to examine the influence that acetonitrile and supporting electrolyte composition, flow rate, column backpressure, and ionic strength have on the structure of electrified interfaces.

  5. Electrochemically modulated liquid chromatography: Theoretical investigations and applications from the perspectives of chromatography and interfacial electrochemistry

    Energy Technology Data Exchange (ETDEWEB)

    Keller, David W. [Iowa State Univ., Ames, IA (United States)

    2005-01-01

    Electrochemically modulated liquid chromatography (EMLC) employs a conductive material as both a stationary phase for chromatographic separations and as a working electrode for performing electrochemistry experiments. This dual functionality gives EMLC the capacity to manipulate chromatographic separations by changing the potential applied (Eapp) to the stationary phase with respect to an external reference. The ability to monitor retention as a function of Eapp provides a means to chromatographically monitor electrosorption processes at solid-liquid interfaces. In this dissertation, the retention mechanism for EMLC is examined from the perspective of electrical double layer theory and interfacial thermodynamics. From the chromatographic data, it is possible to determine the interfacial excess (Λ) of a solute and changes in interfacial tension (dγ) as a function of both Eapp and the supporting electrolyte concentration. Taken together, these two experimentally manipulated parameters can be examined within the context of the Gibbs adsorption equation to delineate the contribution of a variety of interfacial properties, including the charge of solute on the stationary phase and the potential of zero charge (PZC), to the mechanism behind EMLC-based retention. The chromatographic probing of interfacial phenomena is complemented by electroanalytical experiments that exploit the ability to monitor the electronic current flowing through an EMLC column. Cyclic voltammetry and chronoamperometry of an EMLC column are used to determine the electronic performance characteristics of an EMLC column. An electrochemical flow injection analysis of a column is provided in which the current required to maintain a constant Eapp is monitored and provides a way to examine the influence that acetonitrile and supporting electrolyte composition, flow rate, column backpressure, and ionic strength have on the structure of electrified interfaces.

  6. Application of High Performance Liquid Chromatography to Separation of Novel Chiral Tetrahedral Heterometal Clusters

    Institute of Scientific and Technical Information of China (English)

    Xin Yi ZHU; Wei Qiang ZHANG; Yu Hua ZHANG; Li Ren CHEN; Yong Min LI

    2003-01-01

    A series of novel chiral tetrahedral heterometal clusters have firstly been separated oncellulose tris-(3,5-dimethylphenylcarbamate) stationary phase by high performance liquid chrom-atography, using hexane as the mobile phase with various alcohols as modifiers.

  7. Determination of Aspartame, Caffeine, Saccharin, and Benzoic Acid in Beverages by High Performance Liquid Chromatography.

    Science.gov (United States)

    Delaney, Michael F.; And Others

    1985-01-01

    Describes a simple and reliable new quantitative analysis experiment using liquid chromatography for the determinaiton of caffeine, saccharin, and sodium benzoate in beverages. Background information, procedures used, and typical results obtained are provided. (JN)

  8. Determination of maduramicin in feedingstuffs and premixtures by liquid chromatography : development, validation and interlaboratory study

    NARCIS (Netherlands)

    Jong, de J.; Stoisser, B.; Wagner, K.; Tomassen, M.J.H.; Driessen, J.J.M.; Hofman, P.; Putzka, H.A.

    2004-01-01

    A reversed-phase liquid chromatography method for determination of maduramicin in feedingstuffs and premixtures was developed, validated, and interlaboratory studied. The extraction solvent was methanol. Maduramicin was detected at 520 nm after postcolumn derivatization with vanillin. Recovery was

  9. Steroid monochloroacetates : Physical-chemical characteristics and use in gas-liquid chromatography

    NARCIS (Netherlands)

    Molen, H.J. van der; Groen, D.; Maas, J.H. van der

    1965-01-01

    Synthesis and physical-chemical characteristics (melting points, infrared-, visible- and ultraviolet spectra, paper-,thin-layer- and gas-liquid Chromatographie behaviour) of monochloroacetate derivatives of steroids representing the androstane-, pregnane-, estrane- and cholestane series are describe

  10. Two-dimensional liquid chromatography and its application in traditional Chinese medicine analysis and metabonomic investigation.

    Science.gov (United States)

    Li, Zheng; Chen, Kai; Guo, Meng-zhe; Tang, Dao-quan

    2016-01-01

    Two-dimensional liquid chromatography has become an attractive analytical tool for the separation of complex samples due to its enhanced selectivity, peak capacity, and resolution compared with one-dimensional liquid chromatography. Recently, more attention has been drawn on the application of this separation technique in studies concerning traditional Chinese medicines, metabonomes, proteomes, and other complex mixtures. In this review, we aim to examine the application of two-dimensional liquid chromatography in traditional Chinese medicine analysis and metabonomic investigation. The classification and evaluation indexes were first introduced. Then, various switching methods were summarized when used in an on-line two-dimensional liquid chromatography system. Finally, the applications of this separation technique in traditional Chinese medicine analysis and metabonomic investigation were discussed on the basis of specific studies.

  11. Two-dimensional liquid chromatography for direct chiral separations: a review.

    Science.gov (United States)

    León-González, María Eugenia; Rosales-Conrado, Noelia; Pérez-Arribas, Luis Vicente; Guillén-Casla, Vanesa

    2014-01-01

    Separation of enantiomers remains a challenge owing to their identical physical and chemical properties in an achiral environment, and research on specialized separation techniques such as multidimensional achiral-chiral liquid chromatography continues to resolve individual enantiomers in complex samples. Recent advances in application of multidimensional liquid chromatography applied to chiral analysis are reviewed. For this reason, benefits of achiral-chiral coupling are shown, with emphasis in applications on biological and pharmaceutical fields as well as pesticide analysis. A description of standard instrumental setup in both heart-cut and comprehensive multidimensional liquid chromatography is shown. The most broadly used chiral stationary phases for multidimensional liquid chromatography are summarized. An extensive overview of different interface designs applied to complex samples is presented.

  12. New methods and materials for solid phase extraction and high performance liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Dumont, Philip John [Iowa State Univ., Ames, IA (United States)

    1996-04-23

    This paper describes methods for solid phase extraction and high performance liquid chromatography (HPLC). The following are described: Effects of Resin Sulfonation on the Retention of Polar Organic Compounds in Solid Phase Extraction; Ion-Chromatographic Separation of Alkali Metals In Non-Aqueous Solvents; Cation-Exchange Chromatography in Non-Aqueous Solvents; and Silicalite As a Stationary Phase For HPLC.

  13. An efficient hydrophilic interaction liquid chromatography separation of 7 phospholipid classes based on a diol column

    NARCIS (Netherlands)

    Zhu, C.; Dane, A.; Spijksma, G.; Wang, M.; Greef, J. van der; Luo, G.; Hankemeier, T.; Vreeken, R.J.

    2012-01-01

    A hydrophilic interaction liquid chromatography (HILIC) - ion trap mass spectrometry method was developed for separation of a wide range of phospholipids. A diol column which is often used with normal phase chromatography was adapted to separate different phospholipid classes in HILIC mode using a m

  14. [Development of methods for determining acrylamide in food products by gas-liquid chromatography].

    Science.gov (United States)

    Bessonov, V V; Malinkin, A D; Perederiaev, O I; Bogachuk, M N; Volkovich, S V; Medvedev, Iu V

    2011-01-01

    The method of determination of acrylamide in various food (milk powder, potato chips, instant coffee) by gas-liquid chromatography after pre-bromination was developed. Studies have shown the possibility of using bromination of acrylamide to give it the necessary properties for better extraction, purification and detection. Also revealed the possibility of qualitative and quantitative determine a acrylamide in food by gas-liquid chromatography with detection by electron capture detector.

  15. Liquid chromatography-mass spectrometry coupling by the intermediary of a liquid micro chromatography-electro spray interface; Couplage chromatographie liquide-spectrometrie de masse par l`intermediaire d`une interface electrospray-microchromatographie liquide

    Energy Technology Data Exchange (ETDEWEB)

    Gillard Factor, C.

    1996-12-06

    The objective of this work is to realize a liquid chromatography- mass spectrometry coupling by the intermediary of an electro spray interface and the evaluation of performances of tis analytical tool to study pollutants in water, and more particularly pesticides whom maximum admissible concentration in a table water is 0.1{mu}g/l. This study has allowed to bring to the fore the interest of the ionization mode by electro spray in a LC/MS coupling to identify and quantify pesticides in the state of traces without treating the sample. Then, it was demonstrated the usefulness of this analytical tool to detect high molecular masses molecules. (N.C.)

  16. Liquid chromatography method to determine polyamines in thermosetting polymers

    Energy Technology Data Exchange (ETDEWEB)

    Dopico-Garcia, M.S. [Laboratorio de Quimica - Centro de Investigacions Tecnoloxicas, Universidade da Coruna, Campus de Esteiro s/n, 15403 Ferrol (Spain); Centro Galego do Plastico, A Cabana s/n, 15590 Ferrol (Spain); Lopez-Vilarino, J.M. [Laboratorio de Quimica - Centro de Investigacions Tecnoloxicas, Universidade da Coruna, Campus de Esteiro s/n, 15403 Ferrol (Spain); Fernandez-Martinez, G. [Unidad de Tecnicas Cromatograficas, Servizos de Apoio a Investigacion, Edificio Servizos Centrais de Investigacion, Universidade da Coruna, Campus de Elvina s/n, 15071 A Coruna (Spain); Gonzalez-Rodriguez, M.V., E-mail: victoria@udc.es [Dpto. de Quimica Analitica - E.U. Politecnica, Universidade da Coruna, Avda. 19 de Febrero s/n, 15405 Ferrol (Spain)

    2010-05-14

    A simple, robust and sensitive analytical method to determine three polyamines commonly used as hardeners in epoxy resin systems and in the manufacture of polyurethane is reported. The studied polyamines are: one tetramine, TETA (triethylenetetramine), and two diamines, IPDA (Isophorone diamine) and TCD-diamine (4,7-methano-1H-indene-5,?-dimethanamine, octahydro-). The latter has an incompletely defined structure, and, as far as we know, has not been previously determined by other methods. All three polyamines contain primary amines; TETA also contains secondary amines. The analytical method involves derivatization with 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate, used for the first time for these compounds, followed by high performance liquid chromatography (HPLC) analysis with a fluorescence (FL) detector ({lambda} excitation 248 nm, {lambda} emision 395 nm). The HPLC-DAD-LTQ Orbitrap MS was used in order to provide structural information about the obtained derivatized compounds. The hybrid linear ion trap LTQ Orbitrap mass spectrometer has been introduced in recent years and provides a high mass accuracy. The structures of the derivatized analytes were identified from the protonated molecular ions [M+H]{sup +} and corresponded to the fully labelled analytes. The following analytical parameters were determined for the method using the HPLC-FL: linearity, precision (2.5-10%), instrumental precision intraday (0.8-1.5%) and interday (2.9-6.3%), and detection limits (0.02-0.14 mg L{sup -1}). The stability of stock solutions and derivatized compounds was also investigated. The method was applied to determine the amine free content in epoxy resin dust collected in workplaces.

  17. Liquid Chromatography for Analysis of Metformin in Myrmeleon sp.

    Directory of Open Access Journals (Sweden)

    Afidatul Muadifah

    2017-09-01

    Full Text Available Myrmeleon sp is a typical of insect larva which has been used in Indonesia for diabetes treatment. However, there is no sufficient scientific report explaining the bioactive compounds in this insect. Based on our preliminary research, this insect contained metformin, i.e. one of bioactive compounds for the treatment of type-2 diabetes. Therefore, this study is focused on the development of separation technique using high performance liquid chromatography (HPLC on a reverse phase C-18 column with UV detection to identify and quantify metformin in methanol extract of Myrmeleon sp. Several parameters of HPLC method were optimized with respect to high resolution of separation and accurate determination of metformin. Satisfied separation was obtained under gradient elution mode using aqueous methanol mobile phase varied from 50-90 % of methanol with flow rate of 0.5 mL/min and detection wavelength of 233 nm. The method performed total separation for all compounds in less than 11 minutes. Spiking technique was chosen for metformin identification and quantitation. Metformin in extract Myrmeleon sp was eluted at retention time (tR of 4.095 minutes, similarly with retention time of standard metformin of 4.092 minutes. The quantity of metformin in Myrmeleon sp can be simply determined by comparing the additional area of standard metformin with area of metformin from extract Myrmeleon sp. The results confirmed that methanol extract of Myrmeleon sp contained anti-diabetes compound of metformin of 0.58 mg/g Myrmeleon sp larvae with acceptable coefficient variation of 5.56 %.

  18. Tryptophan and kynurenine determination in human hair by liquid chromatography.

    Science.gov (United States)

    Dario, Michelli F; Freire, Thamires Batello; Pinto, Claudinéia Aparecida Sales de Oliveira; Prado, María Segunda Aurora; Baby, André R; Velasco, Maria Valéria R

    2017-09-18

    Tryptophan, an amino acid found in hair proteinaceous structure is used as a marker of hair photodegradation. Also, protein loss caused by several chemical/physical treatments can be inferred by tryptophan quantification. Kynurenine is a photo-oxidation product of tryptophan, expected to be detected when hair is exposed mainly to UVB (290-320nm) radiation range. Tryptophan from hair is usually quantified directly as a solid or after alkaline hydrolysis, spectrofluorimetrically. However, these types of measure are not sufficiently specific and present several interfering substances. Thus, this work aimed to propose a quantification method for both tryptophan and kynurenine in hair samples, after alkali hydrolysis process, by using high-performance liquid chromatography (HPLC) with fluorimetric and UV detection. The tryptophan and kynurenine quantification method was developed and validated. Black, white, bleached and dyed (blond and auburn) hair tresses were used in this study. Tryptophan and kynurenine were separated within ∼9min by HPLC. Both black and white virgin hair samples presented similar concentrations of tryptophan, while bleaching caused a reduction in the tryptophan content as well as dyeing process. Unexpectedly, UV/vis radiation did not promote significantly the conversion of tryptophan into its photo-oxidation product and consequently, kynurenine was not detected. Thus, this works presented an acceptable method for quantification of tryptophan and its photooxidation metabolite kynurenine in hair samples. Also, the results indicated that bleaching and dyeing processes promoted protein/amino acids loss but tryptophan is not extensively degraded in human hair by solar radiation. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Novel liquid chromatography tandem mass spectrometry (LC-MS/MS) methods for measuring steroids.

    Science.gov (United States)

    Keevil, Brian G

    2013-10-01

    Liquid chromatography tandem mass spectrometry (LC-MS/MS) is increasingly becoming the method of choice for steroid hormone measurements due to small sample volumes, fast analysis times and improved specificity compared to immunoassays. Achievement of demanding analytical targets for steroid analysis is now becoming possible because of improvements in sample preparation technology, liquid chromatography column technology and mass spectrometer design. The most popular sample treatment strategies comprise protein precipitation (PP), solid-phase extraction (SLE) and liquid-liquid extraction (LLE). Modern liquid chromatography columns can ensure the adequate separation of isobaric compounds e.g. 21 Deoxycortisol, 11 Deoxycortisol and Corticosterone. The most appropriate method may be chosen to improve assay sensitivity by reducing matrix effects (LLE, SPE) or simplicity and speed (PP). Specific examples of some clinically important steroids including oestradiol, aldosterone, renin, serum cortisol, salivary cortisol and salivary testosterone will be described.

  20. Study of photorespiration in marine microalgae through the determination of glycolic acid using hydrophilic interaction liquid chromatography.

    Science.gov (United States)

    Rigobello-Masini, Marilda; Penteado, José C P; Tiba, Maurício; Masini, Jorge C

    2012-01-01

    Determination of organic acids in intracellular extracts and in the cultivation media of marine microalgae aid investigations about metabolic routes related to assimilation of atmospheric carbon by these organisms, which are known by their role in the carbon dioxide sink. The separation of these acids was investigated by hydrophilic interaction liquid chromatography (HILIC) using isocratic elution with a mobile phase composed of 70:30 v/v acetonitrile/20 mmol/L ammonium acetate buffer (pH 6.8) and detection at 220 nm. HILIC allowed the determinations of glycolic acid, the most important metabolite for the evaluation of the photorespiration process in algae, to be made with better selectivity than that achieved by reversed phase liquid chromatography, but with less detectability. The concentration of glycolic acid was determined in the cultivation media and in intracellular extracts of the algae Tetraselmis gracilis and Phaeodactylum tricornutum submitted to different conditions of aeration: (i) without forced aeration, (ii) aeration with atmospheric air, and (iii) bubbling with N(2). The concentration of glycolic acid had a higher increase as the cultures were aerated with nitrogen, showing higher photorespiratory flux than that occurring in the cultures aerated with atmospheric air.

  1. Supercritical fluid chromatography coupled with in-source atmospheric pressure ionization hydrogen/deuterium exchange mass spectrometry for compound speciation.

    Science.gov (United States)

    Cho, Yunju; Choi, Man-Ho; Kim, Byungjoo; Kim, Sunghwan

    2016-04-29

    An experimental setup for the speciation of compounds by hydrogen/deuterium exchange (HDX) with atmospheric pressure ionization while performing chromatographic separation is presented. The proposed experimental setup combines the high performance supercritical fluid chromatography (SFC) system that can be readily used as an inlet for mass spectrometry (MS) and atmospheric pressure photo ionization (APPI) or atmospheric pressure chemical ionization (APCI) HDX. This combination overcomes the limitation of an approach using conventional liquid chromatography (LC) by minimizing the amount of deuterium solvents used for separation. In the SFC separation, supercritical CO2 was used as a major component of the mobile phase, and methanol was used as a minor co-solvent. By using deuterated methanol (CH3OD), AP HDX was achieved during SFC separation. To prove the concept, thirty one nitrogen- and/or oxygen-containing standard compounds were analyzed by SFC-AP HDX MS. The compounds were successfully speciated from the obtained SFC-MS spectra. The exchange ions were observed with as low as 1% of CH3OD in the mobile phase, and separation could be performed within approximately 20min using approximately 0.24 mL of CH3OD. The results showed that SFC separation and APPI/APCI HDX could be successfully performed using the suggested method.

  2. Analysis of global components in Ganoderma using liquid chromatography system with multiple columns and detectors.

    Science.gov (United States)

    Qian, Zhengming; Zhao, Jing; Li, Deqiang; Hu, Dejun; Li, Shaoping

    2012-10-01

    In present study, a multiple columns and detectors liquid chromatography system for analysis of global components in traditional Chinese medicines was developed. The liquid chromatography system was consist of three columns, including size exclusion chromatography column, hydrophilic interaction chromatography column, and reversed phase chromatography column, and three detectors, such as diode array detector, evaporative light scattering detector, and mass spectrometry detector, based on column switching technique. The developed multiple columns and detectors liquid chromatography system was successfully applied to the analysis of global components, including macromolecular (polysaccharides), high (nucleosides and sugars)-, and low (triterpenes)-polarity small molecular compounds in Ganoderma, a well-known Chinese medicinal mushroom. As a result, one macromolecular chromatographic peak was found in two Ganoderma species, 19 components were identified in Ganoderma lucidum (two sugars, three nucleosides, and 14 triterpenes), and four components (two sugars and two nucleosides) were identified in Ganoderma sinense. The developed multiple columns and detectors liquid chromatography system was helpful to understand comprehensive chemical characters in TCMs.

  3. Determination of dodecylbenzenesulphonates and ethoxylated alkylphenols in liquid pesticide formulations by high-performance liquid chromatography.

    Science.gov (United States)

    Schreuder, R H; Martijn, A

    1988-01-01

    A method is presented for determining mixtures of calcium dodecylbenzene-sulphonate (CaDBS) and ethoxylated alkylphenols in pesticidal emulsifiable concentrates. The pesticide formulations are adsorbed on a pre-concentration column. The active ingredients, the solvents and the emulsifiers are eluted successively by using solvents with increasing polarities. The various homologues of CaDBS and the ethoxylated alkylphenols are separated by reversed-phase high performance liquid chromatography using methanol-water containing tetramethylammonium bromide. The oligomers of the ethoxylated phenols are separated on an aminopropyl-modified column using a solvent gradient (propan-2-ol-water and hexane-tetrahydrofuran). Quantitative results are given for synthetic samples. The degree of ethoxylation of the ethoxylated alkylphenols has been determined and the CaDBS components characterized.

  4. Isolation and purification of uremic middle molecules by multi-step liquid chromatography

    Institute of Scientific and Technical Information of China (English)

    储结根; 何炳林; 刘晓航; 袁直

    2002-01-01

    Isolation and comparison of uremic sera and urine and normal sera and urine were performed by gel permeation chromatography, anion exchange chromatography and re-versed-phase high performance liquid chromatography. Two uremic middle molecular fractions (A and B) were obtained from uremic sera and urine and normal urine by gel permeation chromatography, but not from normal sera. The anion exchange chromatographic results of fraction A from different origins demonstrate that subfraction A-3 could be excreted in urine by healthy subject, but accumulated in uremic serum for renal failure of patient with uremia. After desalinization subfraction A-3 was analyzed by MALDI-TOF-MS. The results show that subfraction A-3 consists of six compounds with molecular weight 839, 873, 1007.94, 1106, 1680 and 2015 respectively. Finally, by reversed-phase high performance liquid chromatography, subfraction A-3 was further resolved into six independent fractions. Thus, the isolation and purification of six middle molecular c

  5. Evaluation of a silicon oxynitride hydrophilic interaction liquid chromatography column in saccharide and glycoside separations.

    Science.gov (United States)

    Wan, Huihui; Sheng, Qianying; Zhong, Hongmin; Guo, Xiujie; Fu, Qing; Liu, Yanfang; Xue, Xingya; Liang, Xinmiao

    2015-05-01

    The retention characteristics of a silicon oxynitride stationary phase for carbohydrate separation were studied in hydrophilic interaction chromatography mode. Four saccharides including mono-, di-, and trisaccharides were employed to investigate the effects of water content and buffer concentration in the mobile phase on hydrophilic interaction liquid chromatography retention. For the tested saccharides, the silicon oxynitride column demonstrated excellent performance in terms of separation efficiency, hydrophilicity, and interesting separation selectivity for carbohydrates compared to the bare silica stationary phase. Finally, the silicon oxynitride hydrophilic interaction liquid chromatography column was employed in the separation of complex samples of fructooligosaccharides, saponins, and steviol glycoside from natural products. The resulting chromatograms demonstrated good separation efficiency and longer retention compared with silica, which further confirmed the advantages and potential application of silicon oxynitride stationary phase for hydrophilic interaction liquid chromatography separation.

  6. An online monitoring system for atmospheric nitrous acid (HONO) based on stripping coil and ion chromatography

    Institute of Scientific and Technical Information of China (English)

    Peng Cheng; Yafang Cheng; Keding Lu; Hang Su; Qiang Yang; Yikan Zou; Yanran Zhao

    2013-01-01

    A new instrument for measuring atmospheric nitrous acid (HONO) was developed,consisting of a double-wail glass stripping coil sampler coupled with ion chromatography (SC-IC).SC-IC is featured by small size (50 × 35 × 25 cm) and modular construction,including three independent parts:the sampling unit,the transfer and supporting unit,and the detection unit.High collection efficiency (> 99%) was achieved with 25 μmol/L Na2CO3 as absorption solution even in the presence of highly acidic compounds.This instrument has a detection limit of 8 pptv at 15 min time resolution,with a measurement uncertainty of 7%.Potentiai interferences from NOx,NO2+SO2,NO2+VOCs,HONO+O3,HNO3,peroxyacetyl nitrite (PAN) and particle nitrite were quantified in laboratory studies and were found to be insignificant under typical atmospheric conditions.Within the framework of the 3C-STAR project,inter-comparison between the SC-IC and LOPAP (long path liquid absorption photometer) was conducted at a rurai site in the Pearl River Delta.Good agreement was achieved between the two instruments over three weeks.Both instruments determined a clear diurnai profile of ambient HONO concentrations from 0.1 to 2.5 ppbv.However,deviations were found for low ambient HONO concentrations (i.e.<0.3 ppbv),which cannot be explained by previous investigated interference species.To accurately determine the HONO budget under illuminated conditions,more intercomparison of HONO measurement techniques is still needed in future studies,especiaily at low HONO concentrations.

  7. Characterization of hydroxypropylmethylcellulose (HPMC) using comprehensive two-dimensional liquid chromatography

    NARCIS (Netherlands)

    Greiderer, A.; Steeneken, L.; Aalbers, T.; Vivó-Truyols, G.; Schoenmakers, P.

    2011-01-01

    Various hydroxyl-propylmethylcellulose (HPMC) polymers were characterized according to size and compositional distributions (percentage of methoxyl and hydroxyl-propoxyl substitution) by means of comprehensive two-dimensional liquid chromatography (LC × LC) using reversed-phase (RP) liquid chromatog

  8. STRUCTURAL CHARACTERIZATION OF THE DECOMPOSITION PRODUCTS OF SALBUTAMOL BY LIQUID-CHROMATOGRAPHY IONSPRAY MASS-SPECTROMETRY

    NARCIS (Netherlands)

    MALKKILAINE, L; BRUINS, AP

    1994-01-01

    Liquid chromatography-ionspray mass spectrometry was used to elucidate the structures of the decomposition products of salbutamol. The best sensitivity in mass spectrometry was achieved by using a mixture of acetonitrile and ammonium formate (10 mM, pH 3.3) as the mobile phase in liquid chromatograp

  9. Dispersive Liquid-Liquid Microextraction and determination of Platinum(IV by High Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    Ali Mazloomifar

    2015-09-01

    Full Text Available A simple, rapid, and efficient procedure, dispersive liquid-liquid microextraction (DLLME, has been developed for the extraction and preconcentration of platinum (IV in environmental water samples. The factors relevant to the microextraction efficiency, such as the kind and volume of extraction and dispersive solvent, the extraction time, the pH in aqueous, and the salt effect, were optimized. Under the optimum conditions , the enrichment factor of this method for platinum was reached at 119. The detection limit for platinum was 0.3 ng mL-1 , and the relative standard deviation (RSD was 0.42% (n = 10 , C = 10 ng mL-1. The method was successfully applied to the determination of trace amounts of platinum in environmental water samples.

  10. Chromatography.

    Science.gov (United States)

    Brantley, L. Reed, Sr.; Demanche, Edna L.; Klemm, E. Barbara; Kyselka, Will; Phillips, Edwin A.; Pottenger, Francis M.; Yamamoto, Karen N.; Young, Donald B.

    This booklet presents some activities on chromatography. Directions for preparing leaf pigment extracts using alcohol are given, and paper chromatography and thin-layer chromatography are described as modifications of the basic principles of chromatography. (KHR)

  11. Chromatography.

    Science.gov (United States)

    Brantley, L. Reed, Sr.; Demanche, Edna L.; Klemm, E. Barbara; Kyselka, Will; Phillips, Edwin A.; Pottenger, Francis M.; Yamamoto, Karen N.; Young, Donald B.

    This booklet presents some activities on chromatography. Directions for preparing leaf pigment extracts using alcohol are given, and paper chromatography and thin-layer chromatography are described as modifications of the basic principles of chromatography. (KHR)

  12. Preparation and evaluation of surface-bonded tricationic ionic liquid silica as stationary phases for high-performance liquid chromatography.

    Science.gov (United States)

    Qiao, Lizhen; Shi, Xianzhe; Lu, Xin; Xu, Guowang

    2015-05-29

    Two tricationic ionic liquids were prepared and then bonded onto the surface of supporting silica materials through "thiol-ene" click chemistry as new stationary phases for high-performance liquid chromatography. The obtained columns of tricationic ionic liquids were evaluated respectively in the reversed-phase liquid chromatography (RPLC) mode and hydrophilic interaction liquid chromatography (HILIC) mode, and possess ideal column efficiency of 80,000 plates/m in the RPLC mode with naphthalene as the test solute. The tricationic ionic liquid stationary phases exhibit good hydrophobic and shape selectivity to hydrophobic compounds, and RPLC retention behavior with multiple interactions. In the HILIC mode, the retention and selectivity were evaluated through the efficient separation of nucleosides and bases as well as flavonoids, and the typical HILIC retention behavior was demonstrated by investigating retention changes of hydrophilic solutes with water volume fraction in mobile phase. The results show that the tricationic ionic liquid columns possess great prospect for applications in analysis of hydrophobic and hydrophilic samples.

  13. Supercritical Fluid Chromatography, Pressurized Liquid Extraction and Supercritical Fluid Extraction

    Energy Technology Data Exchange (ETDEWEB)

    Henry, Matthew C.; Yonker, Clement R.

    2006-06-15

    In this review we examine the related fields of supercritical fluid chromatography (SFC) and supercritical fluid extraction (SFE). We reviewed the published literature in the period from November 2003 to November 2005. Well over 300 papers were published in this period. This large body of work indicates continuing active growth of the field, but an exhaustive review is beyond the scope of this work. We have chosen to include a sampling of publications that best represent the continuing trends and new ideas in the field. In keeping with past reviews on this subject1, we have broadened our scope to include fluid systems operating at high temperature and pressure, but below the critical point. Various terms have been applied to this state: sub-critical fluid extraction, pressurized liquid extraction, and accelerated solvent extraction. The term accelerated solvent extraction has been used by instrument manufacturers to refer to this process, but we will use the more descriptive term pressurized liquid extraction (PLE) to refer to these systems. Most of the research in the field is of an “evolutionary” rather than “revolutionary” nature. As in the previous review period, applications papers make up a majority of the published work. Pharmaceutical applications continue to be a strong theme. Most of the pharmaceutical work has centered on preparative, rather than analytical, separations. Chiral separations are an exception, as analytical scale separations of chiral compounds are an area of intense interest. Food and natural products represent the next largest body of work. Major themes are the isolation and characterization of high-value added foodstuffs, fragrances, and flavor compounds from novel natural materials or agricultural by-products. The areas of food, natural products, and pharmaceutical separation science converge in the area of so-called nutraceuticals. These are typically high-value products, either sold alone or as part of a fortified food, that

  14. Crosslinked polymeric ionic liquids as solid-phase microextraction sorbent coatings for high performance liquid chromatography.

    Science.gov (United States)

    Yu, Honglian; Merib, Josias; Anderson, Jared L

    2016-03-18

    Neat crosslinked polymeric ionic liquid (PIL) sorbent coatings for solid-phase microextraction (SPME) compatible with high-performance liquid chromatography (HPLC) are reported for the first time. Six structurally different PILs were crosslinked to nitinol supports and applied for the determination of select pharmaceutical drugs, phenolics, and insecticides. Sampling conditions including sample solution pH, extraction time, desorption solvent, desorption time, and desorption solvent volume were optimized using design of experiment (DOE). The developed PIL sorbent coatings were stable when performing extractions under acidic pH and remained intact in various organic desorption solvents (i.e., methanol, acetonitrile, acetone). The PIL-based sorbent coating polymerized from the IL monomer 1-vinyl-3-(10-hydroxydecyl) imidazolium chloride [VC10OHIM][Cl] and IL crosslinker 1,12-di(3-vinylbenzylimidazolium) dodecane dichloride [(VBIM)2C12] 2[Cl] exhibited superior extraction performance compared to the other studied PILs. The extraction efficiency of pharmaceutical drugs and phenolics increased when the film thickness of the PIL-based sorbent coating was increased while many insecticides were largely unaffected. Satisfactory analytical performance was obtained with limits of detection (LODs) ranging from 0.2 to 2 μg L(-1) for the target analytes. The accuracy of the analytical method was examined by studying the relative recovery of analytes in real water samples, including tap water and lake water, with recoveries varying from 50.2% to 115.9% and from 48.8% to 116.6%, respectively.

  15. Ionic liquids as novel stationary phases in gas liquid chromatography: inverse or normal isotope effect?

    Science.gov (United States)

    Schmarr, Hans-Georg; Slabizki, Petra; Müntnich, Sabrina; Metzger, Carmen; Gracia-Moreno, Elisa

    2012-12-28

    The separation of deuterated and non-deuterated compounds in gas liquid partitioning chromatography (GLC) on silicone type stationary phase usually results in the inverse isotope effect. With ionic liquids (ILs) as stationary phase, however, this may show a totally different nature. The inverse isotope effect, in which heavier (deuterated) isotopic compounds (isotopologues) elute earlier, is to be expected when van der Waals (London) dispersion forces play a dominant role in the solute-stationary phase interaction. Such (apolar) interactions seem to play only a minor role when ILs are the stationary phases, leading to only a marginal inverse isotope effect, e.g. for the separation of 2,4,6-trichloroanisole and its [(2)H(5)]-isotopologue on 1,12-di(tripropylphosphonium) dodecane bis(trifluoromethansulfonyl) amide (commercialized as SLB-IL59, Supelco). Indeed, with the most polar stationary phase available (commercialized as SLB-IL111; Supelco), this separation showed a normal isotope effect. Further examples are presented and the nature of the isotope effect observed is discussed.

  16. Determination of the triacylglycerol fraction in fish oil by comprehensive liquid chromatography techniques with the support of gas chromatography and mass spectrometry data.

    Science.gov (United States)

    Beccaria, Marco; Costa, Rosaria; Sullini, Giuseppe; Grasso, Elisa; Cacciola, Francesco; Dugo, Paola; Mondello, Luigi

    2015-07-01

    Fish oil made from menhaden (Brevoortia tyrannus) can be used as a dietary supplement for the presence of high levels of the long-chained omega-3 fatty acids, viz. epentaenoic and docosahexanoic. In this work, for the first time, two different multidimensional approaches were developed and compared, in terms of peak capacity, for triacylglycerol characterization. In particular, silver ion chromatography with a silver-ion column and non-aqueous reverse-phase liquid chromatography with a C18 column were tested in both comprehensive (stop-flow) and off-line modes. The use of mass spectra attained by atmospheric pressure chemical ionization for both LC approaches, and the fatty acids methyl esters profile of menhaden oil obtained by gas chromatography analysis, greatly supported the elucidation of the triacylglycerol content in menhaden oil. The off-line approach afforded a better separation and, thus, higher peak capacity to allow identifying and semiquantifying more than 250 triacylglycerols. Such a huge number has never been reported for a menhaden oil sample.The main disadvantage of such an approach over the stop-flow one was the longer analysis time, mainly attributable to solvent exchange between the two dimensions.

  17. Characterization of synthetic dyes by comprehensive two-dimensional liquid chromatography combining ion-exchange chromatography and fast ion-pair reversed-phase chromatography.

    Science.gov (United States)

    Pirok, Bob W J; Knip, Jitske; van Bommel, Maarten R; Schoenmakers, Peter J

    2016-03-04

    In the late 19th century, newly invented synthetic dyes rapidly replaced the natural dyes on the market. The characterization of mixtures of these so-called early synthetic dyes is complicated through the occurrence of many impurities and degradation products. Conventional one-dimensional liquid chromatography does not suffice to obtain fingerprints with sufficient resolution and baseline integrity. Comprehensive two-dimensional liquid chromatography (LC×LC) is employed in this study, with ion-exchange chromatography in the first dimension and fast ion-pair liquid chromatography in the second. Retention in the first dimension is largely determined by the number of charges, while the selection of a small ion-pair reagent (tetramethylammonium hydroxide) in the second dimension causes retention to be largely determined by the molecular structure of the dye. As a result, there is a high degree of orthogonality of the two dimensions, similar to the values typically encountered in GC×GC. The proposed LC×LC method shows a theroretical peak capacity of about 2000 in an analysis time of about three hours. Clear, informative fingerprints are obtained that open a way to a more efficient characterization of dyes used in objects of cultural heritage.

  18. Application of Ionic Liquids in High Performance Reversed-Phase Chromatography

    Science.gov (United States)

    Wang, Ye; Tian, Minglei; Bi, Wentao; Row, Kyung Ho

    2009-01-01

    Ionic liquids, considered “green” chemicals, are widely used in many areas of analytical chemistry due to their unique properties. Recently, ionic liquids have been used as a kind of novel additive in separation and combined with silica to synthesize new stationary phase as separation media. This review will focus on the properties and mechanisms of ionic liquids and their potential applications as mobile phase modifier and surface-bonded stationary phase in reversed-phase high performance liquid chromatography (RP-HPLC). Ionic liquids demonstrate advantages and potential in chromatographic field. PMID:19582220

  19. Application of Ionic Liquids in High Performance Reversed-Phase Chromatography

    Directory of Open Access Journals (Sweden)

    Wentao Bi

    2009-06-01

    Full Text Available Ionic liquids, considered “green” chemicals, are widely used in many areas of analytical chemistry due to their unique properties. Recently, ionic liquids have been used as a kind of novel additive in separation and combined with silica to synthesize new stationary phase as separation media. This review will focus on the properties and mechanisms of ionic liquids and their potential applications as mobile phase modifier and surface-bonded stationary phase in reversed-phase high performance liquid chromatography (RP-HPLC. Ionic liquids demonstrate advantages and potential in chromatographic field.

  20. Partition coefficients of organic compounds in new imidazolium based ionic liquids using inverse gas chromatography.

    Science.gov (United States)

    Revelli, Anne-Laure; Mutelet, Fabrice; Jaubert, Jean-Noël

    2009-06-05

    Partition coefficients of organic compounds in four ionic liquids: 1-ethanol-3-methylimidazolium tetrafluoroborate, 1-ethanol-3-methylimidazolium hexafluorophosphate, 1,3-dimethylimidazolium dimethylphosphate and 1-ethyl-3-methylimidazolium diethylphosphate were measured using inverse gas chromatography from 303.3 to 332.55K. The influence of gas-liquid and gas-solid interfacial adsorption of different solutes on ionic liquids was also studied. Most of the polar solutes were retained largely by partition while light hydrocarbons were retained predominantly by interfacial adsorption on the ionic liquids studied in this work. The solvation characteristics of the ionic liquids were evaluated using the Abraham solvation parameter model.

  1. Using dispersive liquid-liquid microextraction and liquid chromatography for determination of guaifenesin enantiomers in human urine.

    Science.gov (United States)

    Hatami, Mehdi; Farhadi, Khalil; Abdollahpour, Assem

    2011-11-01

    A simple, rapid, and efficient method, dispersive liquid-liquid microextraction (DLLME) coupled with high-performance liquid chromatography-fluorescence detector, has been developed for the determination of guaifenesin (GUA) enantiomers in human urine samples after an oral dose administration of its syrup formulation. Urine samples were collected during the time intervals 0-2, 2-4, and 4-6 h and concentration and ratio of two enantiomers was determined. The ratio of R-(-) to S-(+) enantiomer concentrations in urine showed an increase with time, with R/S ratios of 0.66 at 2 h and 2.23 at 6 h. For microextraction process, a mixture of extraction solvent (dichloromethane, 100 μL) and dispersive solvent (THF, 1 mL) was rapidly injected into 5.0 mL diluted urine sample for the formation of cloudy solution and extraction of enantiomers into the fine droplets of CH(2)Cl(2). After optimization of HPLC enantioselective conditions, some important parameters, such as the kind and volume of extraction and dispersive solvents, extraction time, temperature, pH, and salt effect were optimized for dispersive liquid-liquid microextraction process. Under the optimum extraction condition, the method yields a linear calibration curve in the concentration range from 10 to 2000 ng/mL for target analytes. LOD was 3.00 ng/mL for both of the enantiomers. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Identification of Explosives from Porous Materials: Applications Using Reverse Phase High Performance Liquid Chromatography and Gas Chromatography

    Science.gov (United States)

    Miller, C. J.; Elias, G.; Schmitt, N. C.; Rae, C.

    2010-06-01

    High performance liquid chromatography and gas chromatography techniques are well documented and widely used for the detection of trace explosives from organic solvents. These techniques were modified to identify and quantify explosives extracted from various materials taken from people who had recently handled explosives. Documented techniques were modified to specifically detect and quantify trace levels of the military explosives, RDX, TNT, and PETN from denim, colored flannel, vinyl, and canvas extracted in methanol and filtered using no additional sample cleanup of the sample extract prior to analysis. The filtered methanol extracts were injected directly into several different column types and analyzed by high performance liquid chromatography using ultraviolet detection and/or gas chromatography using electron capture detection. This paper describes general screening methods that were used to determine the presence of explosives (RDX, TNT, and PETN) in unknown samples of denim, colored flannel, vinyl and canvas in addition to techniques that have been optimized for quantification of each explosive from the substrate extracts.

  3. Heat exchanges in fast, high-performance liquid chromatography. A complete thermodynamic study

    Energy Technology Data Exchange (ETDEWEB)

    Gritti, Fabrice [University of Tennessee, Knoxville (UTK); Guiochon, Georges A [ORNL

    2008-01-01

    The successive physical transformations of the mobile phase that take place in very high pressure liquid chromatography were studied based on the formalism of classical thermodynamics. The eluent is initially under atmospheric pressure (P{sup 0}) and at ambient temperature (T{sub ext}). In a first step, it is compressed to a high pressure (P{sub max} of the order of 1 kbar) in the pump heads of the chromatograph. In a second step, the pressurized eluent is transferred to the inlet of the chromatographic column, along which, in a third step, it is decompressed to atmospheric pressure. Both the compression and the decompression of the fluid were considered to take place under conditions that can be either adiabatic or nonadiabatic and either reversible or irreversible. Applications of the first and second principles of thermodynamics allow the determination of the heat and energy exchanged between the eluent and the external surroundings during each transformation. Experimental data were acquired using acetonitrile as the mobile phase. The true state equation, {rho}(P, T), of liquid acetonitrile was used in the theoretical calculations. A series of four different flow rates (0.55, 0.85, 1.15, and 1.45 mL/min, corresponding to inlet pressures of 357.2, 559.5, 765.1, and 972.9 bar, respectively), were applied to a 2.1 x 100 mm column packed with 1.7-{micro}m bridged ethane-silicon hybrid particles. Thermocouples were used to measure the eluent temperature before and after its passage through the column. These data provide estimates of the variation of the internal energy of the eluent. The heat lost through the external wall of the column during the eluent decompression was estimated by measuring the surface temperature of the column tube under steady state. Both the compression and the decompression of acetonitrile were found to be nonadiabatic and irreversible transformations. The results showed that, during the eluent decompression, the heat released by the friction

  4. Separation of Nitration By-Products in Commercial-Grade Trinitro-Toluene by High Performance Liquid Chromatography.

    Science.gov (United States)

    1982-06-01

    MRL-TN-464 SEPARATION OF NITRATION BY-PRODUCTS IN COMMERCIAL-GRADE TITR-TOLUENE BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY Peter J. Sanders ABSTRACT...UNCLASSIFIED TITLE SEPARATION OF NITRATION BY-PRODUCTS IN COMMERCIAL-GRADE TRXNITRO-TOLUENE BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY AUTHOR(S...PRODUCTS IN COMMERCIAL-GRADE TRINITRO-TOLUENE BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY 16 INTRODUCTION Fbr some time, a need has existed for the

  5. Analysis of chlorpheniramine in human urine samples using dispersive liquid-liquid microextraction combined with high-performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Mehdi Maham

    2014-09-01

    Full Text Available A simple and environmentally friendly microextraction technique was used for determination of chlorpheniramine (CPM, an antihistamine drug, in human urine samples using dispersive liquid-liquid microextraction (DLLME followed by high performance liquid chromatography with diode array detection (HPLC-DAD. In this extraction technique, an appropriate mixture of acetonitrile (disperser solvent and carbon tetrachloride (extraction solvent was rapidly injected into the urine sample containing the target analyte. Tiny droplets of extractant were formed and dispersed into the sample solution and then sedimented at the bottom of the conical test tube by centrifugation. Under optimal conditions, the calibration curve was linear in the range of 0.055-5.5 µg mL-1, with a detection limit of 16.5 ng mL-1. This proposed method was successfully applied to the analysis of real urine samples. Low consumption of toxic organic solvents, simplicity of operation, low cost and acceptable figures of merit are the main advantages of the proposed technique.

  6. Optimization and Application of Liquid Chromatography Determination of Dispersive Liquid-liquid Microextraction Purified Astaxanthin in Shrimp Waste

    Institute of Scientific and Technical Information of China (English)

    ZHU Tao; ROW Kyung-ho

    2013-01-01

    A new molecularly imprinted solid-phase extraction(MISPE) monolithic cartridge was synthesized,and MISPE-DLLME(DLLME=dispersive liquid-liquid microextraction) was developed for purification of astaxanthin in shrimp waste.The eluent(methanol) from MISPE was used as the dispersive solvent in subsequent DLLME for further purifying and enriching the analyte prior to high-performance liquid chromatography(HPLC) analysis.The mobile phase was methanol-acetonitrile-water-dichloromethane(85:5:5:5,volume ratio),flow rate was 0.7 mL/min and UV wavelength was 476 nm.Under optimal conditions,good linearity was obtained in a range of 0.2-200.0 μg/mL(r2=0.9998) with a limit of detection(LOD) of 0.08 μg/mL,and the extraction recoveries at three spiked levels ranged from 88.3%-92.5% with a relative standard deviation(RSD) less than 4.3%.Moreover,the mean contents of astaxanthin in the three batches of shrimp waste were 95.9,85.4 and 77.2 μg/g,respectively.This method combining the advantages of MISPE and DLLME results in high selectivity and low cost,which was applied to determining the astaxanthin level in shrimp waste samples.

  7. Quality evaluation of moluodan concentrated pill using high-performance liquid chromatography fingerprinting coupled with chemometrics.

    Science.gov (United States)

    Tao, Lingyan; Zhang, Qing; Wu, Yongjiang; Liu, Xuesong

    2016-12-01

    In this study, a fast and effective high-performance liquid chromatography method was developed to obtain a fingerprint chromatogram and quantitative analysis simultaneously of four indexes including gallic acid, chlorogenic acid, albiflorin and paeoniflorin of the traditional Chinese medicine Moluodan Concentrated Pill. The method was performed by using a Waters X-bridge C18 reversed phase column on an Agilent 1200S high-performance liquid chromatography system coupled with diode array detection. The mobile phase of the high-performance liquid chromatography method was composed of 20 mmol/L phosphate solution and acetonitrile with a 1 mL/min eluent velocity, under a detection temperature of 30°C and a UV detection wavelength of 254 nm. After the methodology validation, 16 batches of Moluodan Concentrated Pill were analyzed by this high-performance liquid chromatography method and both qualitative and quantitative evaluation results were achieved by similarity analysis, principal component analysis and hierarchical cluster analysis. The results of these three chemometrics were in good agreement and all indicated that batch 10 and batch 16 showed significant differences with the other 14 batches. This suggested that the developed high-performance liquid chromatography method could be applied in the quality evaluation of Moluodan Concentrated Pill.

  8. Systematic comparison of sensitivity between hydrophilic interaction liquid chromatography and reversed phase liquid chromatography coupled with mass spectrometry.

    Science.gov (United States)

    Periat, Aurélie; Boccard, Julien; Veuthey, Jean-Luc; Rudaz, Serge; Guillarme, Davy

    2013-10-18

    Hydrophilic interaction liquid chromatography (HILIC) appears as a promising strategy to increase sensitivity with electrospray ionization source (ESI/MS). In the present study, peak heights, background noises and signal-to-noise ratios (S/N) obtained with HILIC-MS/MS and RPLC-MS/MS conditions were systematically compared using a dataset of 56 basic drugs possessing diverse physico-chemical properties. Various mobile phase conditions were investigated, including different pH (3 and 6 in HILIC; 3, 6 and 9 in RPLC) and flow rates (300, 600 and 1000μL/min). The average gain in sensitivity obtained between HILIC and RPLC was equal to 7 and 10 at pH 3 and 6, respectively. However, this value was not reliable, since it was altered by a few compounds possessing an "extreme" behaviour (gain in sensitivity from 100-fold to >8000-fold better). Then, the median gain in sensitivity, equal to 4 in our case, whatever the pH, should be considered. For about 90% of the tested compounds and analytical conditions, the best S/N was systematically attained under HILIC mode. Thanks to PCA representation, it was shown that the basic compounds with pKa between 6 and 8 generally had the best sensitivity in HILIC at pH 6, while the best sensitivity for basic analytes possessing pKa higher than 8 was usually obtained in HILIC at pH 3. As previously reported, the sensitivity gain in HILIC vs. RPLC was explained by the difference in acetonitrile concentration at elution (in average 29% ACN in RPLC and 82% ACN in HILIC at pH 6) leading to better analytes' desolvation. However, it seems that this high proportion of solvent also favourably influenced the ionization by modifying pH and pKa. Indeed the weakest bases of our training set of compounds (pKa between 2 and 5) showed an unexpectedly strong gain in sensitivity, between 20 and 100-fold in comparison to RPLC. These results prove that the ionic character of analytes in solution (i.e., pKa and pH) and the ionization mechanism (i.e., proton

  9. SFC-APLI-(TOF)MS: Hyphenation of Supercritical Fluid Chromatography to Atmospheric Pressure Laser Ionization Mass Spectrometry.

    Science.gov (United States)

    Klink, Dennis; Schmitz, Oliver Johannes

    2016-01-05

    Atmospheric-pressure laser ionization mass spectrometry (APLI-MS) is a powerful method for the analysis of polycyclic aromatic hydrocarbon (PAH) molecules, which are ionized in a selective and highly sensitive way via resonance-enhanced multiphoton ionization. APLI was presented in 2005 and has been hyphenated successfully to chromatographic separation techniques like high performance liquid chromatography (HPLC) and gas chromatography (GC). In order to expand the portfolio of chromatographic couplings to APLI, a new hyphenation setup of APLI and supercritical-fluid chromatography (SFC) was constructed and aim of this work. Here, we demonstrate the first hyphenation of SFC and APLI in a simple designed way with respect to different optimization steps to ensure a sensitive analysis. The new setup permits qualitative and quantitative determination of native and also more polar PAH molecules. As a result of the altered ambient characteristics within the source enclosure, the quantification of 1-hydroxypyrene (1-HP) in human urine is possible without prior derivatization. The limit of detection for 1-HP by SFC-APLI-TOF(MS) was found to be 0.5 μg L(-1), which is lower than the 1-HP concentrations found in exposed persons.

  10. Isolation and purification of six iridoid glycosides from gardenia jasminoides fruit by medium-pressure liquid chromatography combined with macroporous resin chromatography.

    Science.gov (United States)

    Wang, Yun; Liu, Hui; Shen, Lifeng; Yao, Lan; Ma, Yinlian; Yu, Dingrong; Chen, Jianhong; Li, Puling; Chen, Ying; Zhang, Cun

    2015-12-01

    Gardeniae fructus is one of the most frequently used herbs in traditional Chinese medicine. In the present study, a process for the enrichment of six iridoid glycosides from Gardeniae fructus was developed using medium-pressure liquid chromatography combined with macroporous resin and reversed-phase chromatography. The purities of different fractions from Gardeniae fructus were assessed using quantitative high-performance liquid chromatography. After fractionation using HPD-100 column chromatography, a 30% ethanol fraction was selected based on high-performance liquid chromatography and liquid chromatography with mass spectrometry qualitative analysis to separate and purify. Based on the orientation analysis results, six compounds-deacetyl asperulosidic acid methyl ester, gardenoside, ixoroside, scandoside methyl ester, genipin-1-O-β-d-gentiobioside, and geniposide-were successfully isolated and purified in three to four combined steps from Gardeniae fructus. The purities of these compounds were found by high-performance liquid chromatography analysis to be 97.9, 98.1, 95.5, 96.3, 97.1, and 98.7%, respectively. Moreover, their structures were elucidated by NMR spectroscopy and liquid chromatography with tandem mass spectrometry. The separation process was highly efficient, rapid, and accurate, making it a potential approach for the large-scale production of iridoids in the laboratory and providing several marker compounds for quality control. This procedure may be meaningful for the purification of other natural products used in traditional Chinese medicine.

  11. Screening and quantitative determination of twelve acidic and neutral pharmaceuticals in whole blood by liquid-liquid extraction and liquid chromatography-tandem mass spectrometry

    DEFF Research Database (Denmark)

    Simonsen, Kirsten Wiese; Steentoft, Anni; Buck, Maike

    2010-01-01

    . The method was fully validated for salicylic acid, paracetamol, phenobarbital, carisoprodol, meprobamate, topiramate, etodolac, chlorzoxazone, furosemide, ibuprofen, warfarin, and salicylamide. The method also tentatively includes thiopental, theophylline, piroxicam, naproxen, diclophenac, and modafinil......We describe a multi-method for simultaneous identification and quantification of 12 acidic and neutral compounds in whole blood. The method involves a simple liquid-liquid extraction, and the identification and quantification are performed using liquid chromatography-tandem mass spectrometry...

  12. Analytical confirmation of lethal heroin overdose by the use of liquid chromatography methods

    Directory of Open Access Journals (Sweden)

    Đorđević Snežana

    2007-01-01

    Full Text Available Background/Aim. Heroin is diacetylated morphine. Its ability to induce euphoria has led to its frequent abuse, giving rise to psychological and physical dependence. It has a short half-life, of approximately 2−6 min. In the brain, heroin undergoes deacetylation to 6-monoacetylmorphine (6−MAM and morphine. Detection of 6-acetylmorphine in the urine is indicative of heroin use. The aim of this study was to compare sensitivity and reliability of two analytical methods, a multicolumn liquid chromatography system with UV scanning detector (HPLCUV and liquid chromatography-mass spectrometry detection (LC-MS in opiate determining in post mortem material. Methods. Post mortem samples (blood, urine and vitreous humor were analyzed by liquid chromatography with UV and MS detection. The samples were prepared by liquid-liquid extraction with mixture chloroform-isopropanol (9:1. Separation was performed on C8 column with mobile phase composed of 55% acetonitrile-glacial acetic acid (99:1 and 45% 20 mM ammonium acetate. Results. The analysis of blood samples, urine, and eye liquid by the use of multicolumn HPLC-UV method confirmed the presence of morphine in the samples of blood and urine, codeine only in urine, and 6-MAM in the samples of urine and eye liquid. Using LC-MS method morphine was confirmed in all of the samples, while codeine was confirmed in urine and in the sample of eye liquid. In the samples of eye liquid and urine 6-MAM was confirmed. Conclusion. For determination of opiates in post mortem material LC-MS technique is more sensitive and reliable as compared to multicolumn liquid chromatography.

  13. The Application of High Performance Liquid Chromatography in the Analysis of Trace Rare Earth

    Institute of Scientific and Technical Information of China (English)

    WANG; Xiu-feng; DING; You-qian

    2012-01-01

    <正>Rare earth elements are very important in the field of radioanalytical chemistry, for it must be separated and determined in the measurements of burn-up and fission yield. High performance liquid chromatography has become a main method in the separation of rare earth elements due to its obvious advantages, this is, high speed of analysis, high efficiency and easy automation. The ion exchange chromatography is the main means to separate rare earth elements, especially the cation exchange

  14. DETERMINATION OF ACRYLAMIDE IN FOOD BY GAS AND LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY

    OpenAIRE

    Michaela Vieriková; Miriam Vlčáková

    2010-01-01

     Acrylamide in food was determined by gas chromatography - mass spectrometry (GC-MS) after bromination of acrylamide and underivatized acrylamide was quantified by ultra performance liquid chromatography -mass spectrometry (UPLC-MS). Two different sample preparation methods were used and optimised. The GC-MS method was used for various food matrices like breads, potato crisps, potato crackers, french fries. The UPLC-MS method was used for analysis of coffee. The limit of detect...

  15. Plasma lipid analysis by hydrophilic interaction liquid chromatography coupled with electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Sonomura, Kazuhiro; Kudoh, Shinobu; Sato, Taka-Aki; Matsuda, Fumihiko

    2015-06-01

    A novel method for the analysis of endogenous lipids and related compounds was developed employing hydrophilic interaction liquid chromatography with electrospray ionization tandem mass spectrometry. A hydrophilic interaction liquid chromatography with carbamoyl stationary phase achieved clear separation of phosphatidylcholine, lysophosphatidylcholine, sphingomyelin, ceramide, and mono-hexsosyl ceramide groups with good peak area repeatability (RSD% 0.99). The established method was applied to human plasma assays and a total of 117 endogenous lipids were successfully detected and reproducibly identified. In addition, we investigated the simultaneous detection of small polar metabolites such as amino and organic acids co-existing in the same biological samples processed in a single analytical run with lipids. Our results show that hydrophilic interaction liquid chromatography is a useful tool for human plasma lipidome analysis and offers more comprehensive metabolome coverage.

  16. Surface Confined Ionic Liquid-A New Stationary Phase for the Separation of Ephedrines in High-performance Liquid Chromatography

    Institute of Scientific and Technical Information of China (English)

    Shu Juan LIU; Feng ZHOU; Xiao Hua XIAO; Liang ZHAO; Xia LIU; Sheng Xiang JIANG

    2004-01-01

    In this article, a new and effective stationary phase based on ionic liquid modified silica is first reported and used for the separation of ephedrines in high-performance liquid chromatography (HPLC). The separation results indicate the high efficiency and reproducibility of the stationary phase. The electrostatic interaction, ion-exchange interaction between the solutes and the stationary phase are considered to attribute the effective separation. Moreover, the free silanols on the surface of the silica are effectively masked by the immobilized ionic liquid, a result of which is to decrease the non-specific absorption.

  17. Determination of muscimol and ibotenic acid in Amanita mushrooms by high-performance liquid chromatography and liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Tsujikawa, Kenji; Kuwayama, Kenji; Miyaguchi, Hajime; Kanamori, Tatsuyuki; Iwata, Yuko; Inoue, Hiroyuki; Yoshida, Takemi; Kishi, Tohru

    2007-06-01

    A reliable analytical method was developed for the quantification and identification of muscimol (MUS) and ibotenic acid (IBO), the toxic constituents of Amanita muscaria and Amanita pantherina. MUS and IBO were extracted from mushrooms by aqueous methanol and derivatized with dansyl chloride (DNS-Cl). After extraction with ethyl acetate and evaporation of the solvent, the residue was ethylated with 1.25 M hydrogen chloride in ethanol. The resulting derivatives were quantified by high-performance liquid chromatography with UV detection and identified by liquid chromatography electrospray ionization tandem mass spectrometry. Calibration curves were linear in the range of 25-2500 ppm for MUS and 40-2500 ppm for IBO, respectively. This method was successfully applied to identify and quantify MUS and IBO in Amanita mushrooms naturally grown and circulated in the drug market.

  18. On-line comprehensive two-dimensional normal-phase liquid chromatography×reversed-phase liquid chromatography for preparative isolation of toad venom.

    Science.gov (United States)

    Li, Jia-Fu; Fang, Hua; Yan, Xia; Chang, Fang-Rong; Wu, Zhen; Wu, Yun-Long; Qiu, Ying-Kun

    2016-07-22

    An on-line comprehensive preparative two-dimensional normal-phase liquid chromatography×reversed-phase liquid chromatography (2D NPLC×RPLC) system was constructed with a newly developed vacuum evaporation assisted adsorption (VEAA) interface, allowing fast removal of NPLC solvent in the vacuum condition and successfully solving the solvent incompatibility problem between NPLC and RPLC. The system achieved on-line solvent exchange within the two dimensions and its performance was illustrated by gram-scale isolation of crude extract from the venom of Bufo bufo gargarizans. Within separation time of ∼20h, 19 compounds were obtained with high purity in a single run. With the VEAA interface, the 2D system exhibited apparent advantages in separation efficiency and automation compared with conventional methods, indicating its promising application in the routine separation process for complicated natural products.

  19. Ultrasound-assisted ionic liquid-based homogeneous liquid-liquid microextraction high-performance liquid chromatography for determination of tanshinones in Salvia miltiorrhiza Bge. root.

    Science.gov (United States)

    Wang, Zhibing; Cao, Bocheng; Yu, Aimin; Zhang, Hanqi; Qiu, Fangping

    2015-02-01

    The ultrasound-assisted ionic liquid-based homogeneous liquid-liquid microextraction has been developed and applied to the extraction of four tanshinones, including dihydrotanshinone, tanshinone I, cryptotanshinone and tanshinone IIA in Salvia miltiorrhiza Bge. root. High performance liquid chromatography was applied to the separation and determination of the analytes. The ionic liquid was used as extraction solvent and target analytes were extracted with help of ultrasound. Then, ion-pairing agent was added into the sample solution, which resulted in the formation of water-insoluble ionic liquid in the solution. The phase separation was performed by centrifugation. The extraction, concentration and purification of target analytes were performed simultaneously. The experimental parameters, including type and volume of ionic liquid, sample amount, the size of sample particle, pH value of extraction medium, extraction temperature, extraction time, amount of ion-pairing agent and centrifuging time, were investigated and optimized. The calibration curves showed good linear relationship (r>0.9997). The limits of detection and quantification were in the range of 0.052-0.093 and 0.17-0.31 μg mL(-1), respectively. The recoveries were between 70.45% and 94.23% with relative standard deviations lower than 5.31%. The present method is free of volatile organic solvents, and represents lower expenditures of sample, extraction time and solvent, compared with UAE and HRE. There was no obvious difference in the extraction yields of active constitutions obtained by the three extraction methods.

  20. Fluorimetric assay for ornithine decarboxylase by high-performance liquid chromatography.

    Science.gov (United States)

    Haraguchi, K; Kai, M; Kohashi, K; Ohkura, Y

    1980-12-05

    A highly sensitive method for the assay of ornithine decarboxylase in sample solutions prepared from rat tissue homogenate is described which employs high-performance liquid chromatography with fluorescence detection. Putrescine formed from ornithine under the optimal conditions for the enzyme reaction is treated by Cellex P column chromatography for clean-up and converted into the fluorescamine derivative in the presence of cupric ion which inhibits the reaction of interfering amines with fluorescamine. The derivative is separated by reversed-phase chromatography on LiChrosorb RP-18 with linear gradient elution. The lower limit of detection for putrescine formed enzymatically is 5 pmol.

  1. High-performance liquid chromatography of oligoguanylates at high pH

    Science.gov (United States)

    Stribling, R.; Deamer, D. (Principal Investigator)

    1991-01-01

    Because of the stable self-structures formed by oligomers of guanosine, standard high-performance liquid chromatography techniques for oligonucleotide fractionation are not applicable. Previously, oligoguanylate separations have been carried out at pH 12 using RPC-5 as the packing material. While RPC-5 provides excellent separations, there are several limitations, including the lack of a commercially available source. This report describes a new anion-exchange high-performance liquid chromatography method using HEMA-IEC BIO Q, which successfully separates different forms of the guanosine monomer as well as longer oligoguanylates. The reproducibility and stability at high pH suggests a versatile role for this material.

  2. Comprehensive two-dimensional normal-phase liquid chromatography × reversed-phase liquid chromatography for analysis of toad skin.

    Science.gov (United States)

    Li, Jia-Fu; Yan, Xia; Wu, Yun-Long; Fang, Mei-Juan; Wu, Zhen; Qiu, Ying-Kun

    2017-04-15

    An analytical two-dimensional normal-phase liquid chromatography × reversed-phase liquid chromatography (2D NPLC × RPLC) system was constructed with a newly developed thermal evaporation assisted adsorption (TEAA) interface. This novel TEAA interface with heating temperature above solvent boiling point allowed fast removal of organic NPLC solvent and successfully solved the solvent incompatibility problem between NPLC and RPLC. The system achieved rapid on-line solvent exchange between the two dimensions within a short modulation time of 190 s and was applied in the analysis of an extract from the skin of Bufo bufo gargarizans. This is the first time to realize the on-line comprehensive analysis of a moderate polar natural product by coupling NPLC with reversed phase ultra-high performance liquid chromatography (UHPLC). To be highlighted, with the TEAA interface, the 2D NPLC × RPLC system provided excellent resolution and orthogonality (75.2%), when compared with that of 2D RPLC × RPLC.

  3. Preparation and chromatographic evaluation of a newly designed steviol glycoside modified-silica stationary phase in hydrophilic interaction liquid chromatography and reversed phase liquid chromatography.

    Science.gov (United States)

    Liang, Tu; Fu, Qing; Shen, Aijin; Wang, Hui; Jin, Yu; Xin, Huaxia; Ke, Yanxiong; Guo, Zhimou; Liang, Xinmiao

    2015-04-03

    A diterpene glycoside compound, rebaudioside A (commonly abbreviated as RA), was immobilized onto porous silica surface through "thiol-ene" click chemistry strategy. The successful immobilization of the RA on the silica support was confirmed by FT-IR and elemental analysis. Chromatographic characteristics of the new stationary phase, named Click TE-RA, were evaluated by a set of diverse analytes such as carbohydrates, nucleosides, and organic acids in hydrophilic interaction liquid chromatography (HILIC) mode. The effects of water content, buffer pH and concentration were investigated and a typical HILIC retention feature of Click TE-RA was observed at high organic modifier content. The Click TE-RA stationary phase was further studied by a series of glycoside compounds. Tunable retention mechanisms from hydrophilic to hydrophobic interactions were observed. Separation of very polar compounds including oligosaccharides, nucleic acid bases and nucleosides using Click TE-RA in HILIC mode was successfully accomplished. In addition, separation of saponins both in HILIC and reversed-phase liquid chromatography (RPLC) modes was performed, demonstrating the presence of orthogonality between two different modes on Click TE-RA column. The multiple interactions induced by polar sugar group and hydrophobic aglycone group allowed this Click TE-RA to serve as a multi-mode stationary phase in two-dimensional liquid chromatography.

  4. [Simultaneous determination of three antioxidants BHA, BHT and TBHQ in food by liquid chromatography and gas chromatography].

    Science.gov (United States)

    Yang, Jie; Fang, Congrong; Yang, Dajin

    2013-01-01

    To develop a method for determining 3 kinds of antioxidants in food in same time with HPLC and GC. Firstly, extracted fat with petroleum ether, then extracted antioxidants with 13 ml methnol, centrifuged, repeated the above procedure twice, combined the extracts, next evaporated to 5 ml, constanted volume to 10 ml, then kepted in freezer (- 1h), lastly, the supernatant injected into high performance liquid chromatography (HPLC) and Gas chromatography (GC) which had been optimized condition. The limits of quantitation for BHA,BHT and TBHQ were 0.002, 0.010 and 0.002g/kg respectively in HPLC, The limits of quantitation for BHA, BHT and TBHQ were 0.003, 0.002 and 0.005 g/kg respectively in GC, The mean recoveries at the two spiked levels were 82.8% - 109.0%. There were no significant difference between HPLC and GC. The method can be used to determine the antioxidants in food accurately and sensitively, the comparative results are constant between liquid and gas chromatography.

  5. Simultaneous liquid chromatography-mass spectrometry quantification of cefixime and clavulanic acid in human plasma.

    Science.gov (United States)

    Dubala, Anil; Nagarajan, Janaki Sankarachari Krishnan; Vimal, Chandran Sathish; George, Renjith

    2015-01-01

    A simple and specific liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry (LC-APCI-MS) assay method has been developed and fully validated for the simultaneous quantification of cefixime (CX) and clavulanic acid (CA) in human plasma. Analytes and internal standard were extracted from human plasma by a solid phase extraction technique using a Sam prep (3 mL, 100 mg) extraction cartridge. The extracted samples were chromatographed on a reverse phase C18 column using a mixture of methanol : acetonitrile : 2 mM ammonium acetate (pH 3.5) (25 : 25 : 50, v/v/v) as the mobile phase at a flow rate of 0.8 mL/min. Quantification of the analytes were carried out using single quadrupole LC-APCI-MS through selected ion monitoring at m/z 452 and 198, respectively, for CX and CA. The assay was linear over the concentration range of 0.05-10.0 and 0.1-10.0 μg/mL, respectively, for CX and CA. The mean plasma extraction recoveries of the CX and CA were found to be 95.20-96.27% and 94.67-95.58%, respectively. The method was successfully applied for the determination of pharmacokinetics of CX and CA after oral administration of single dosage CX/CA (200/125 mg) pill to the humans (n = 12).

  6. Quantitative profiling of retinyl esters in milk from different ruminant species by using high performance liquid chromatography-diode array detection-tandem mass spectrometry.

    Science.gov (United States)

    Rocchi, Silvia; Caretti, Fulvia; Gentili, Alessandra; Curini, Roberta; Perret, Daniela; Pérez-Fernández, Virginia

    2016-11-15

    An effective high performance liquid chromatography-diode array detection-tandem mass spectrometry (HPLC-DAD-MS/MS) analytical approach was developed for retinoid profiling in raw milk samples (cow, buffalo, ewe, and goat). The analytes were isolated by means of liquid-liquid extraction, including a "lipid freezing" step, with yields exceeding 66%. Since the positive atmospheric pressure chemical ionisation mass spectrometry (APCI-MS) detection is not completely selective, a reliable identification has been accomplished by fully separating the analytes on a tandem C18/C30 column system under non-aqueous reversed phase (NARP) chromatography conditions. After validation, different milk varieties obtained from pasture-fed animals were analysed, providing, for the first time, the retinoid composition of both buffalo's and ewe's milk. According to the literature, retinyl palmitate has been found to be the most abundant vitamin A vitamer, but retinyl oleate is the prevalent form in the caprine milk.

  7. Determination of five antiarrhythmic drugs in human plasma by dispersive liquid-liquid microextraction and high-performance liquid chromatography.

    Science.gov (United States)

    Jouyban, Abolghasem; Sorouraddin, Mohammad Hossein; Farajzadeh, Mir Ali; Somi, Mohammad Hossein; Fazeli-Bakhtiyari, Rana

    2015-03-01

    A fast and sensitive high-performance liquid chromatography (HPLC) method with ultraviolet (UV) detection was developed and validated for the simultaneous quantitation of five antiarrhythmic drugs (metoprolol, propranolol, carvedilol, diltiazem, and verapamil) in human plasma samples. It involves dispersive liquid-liquid microextraction (DLLME) of the desired drugs from 660 µL plasma and separation using isocratic elution with UV detection at 200 nm. The complete separation of all analytes was achieved within 7 min. Acetonitrile (as disperser solvent) resulting from the protein precipitation procedure was mixed with 100 µL dichloromethane (as an extraction solvent) and rapidly injected into 5 mL aqueous solution (pH 11.5) containing 1% (w/v), NaCl. After centrifugation, the sedimented phase containing enriched analytes was collected and evaporated to dryness. The residue was re-dissolved in 50 µL de-ionized water (acidified to pH 3) and injected into the HPLC system for analysis. Under the optimal conditions, the enrichment factors and extraction recoveries ranged between 4.4-10.8 and 33-82%, respectively. The suggested method was linear (r(2) ≥0.997) over a dynamic range of 0.02-0.80 µg mL(-1) in plasma. The intra- and inter-days relative standard deviation (RSD%) and relative error (RE%) values of the method were below 20%, which shows good precision and accuracy. Finally, this method was applied to the analysis of real plasma samples obtained from the patients treated with these drugs.

  8. Analysis of drugs of abuse in human plasma by dispersive liquid-liquid microextraction and high-performance liquid chromatography.

    Science.gov (United States)

    Fernández, P; Regenjo, M; Bermejo, A M; Fernández, A M; Lorenzo, R A; Carro, A M

    2015-04-01

    Opioids and cocaine are widely used at present, both for recreational purposes and as drugs of abuse. This raises the need to develop new analytical methods specifically designed for the simultaneous detection of several drugs of abuse in biological samples. In this work, dispersive liquid-liquid microextraction (DLLME) was assessed as a new sample treatment for the simultaneous extraction of morphine (MOR), 6-acetylmorphine (6AM), cocaine (COC), benzoylecgonine (BZE) and methadone (MET) from human plasma. Preliminary assays were done before developing an experimental design based on a Uniform Network Doehlert which allowed the optimum extraction conditions to be identified, namely: a volume of extractant solvent (chloroform) and dispersant solvent (acetonitrile) of 220 µl and 3.2 ml, respectively; 0.2 g of NaCl as a salting-out additive; pH 10.6 and ultrasound stirring for 3.5 min. The resulting extracts were analyzed by high-performance liquid chromatography with photodiode array detection (HPLC-PDA), using an XBridge® RP18 column (250 × 4.6 mm i.d., 5 µm particle size). Calibration graphs were linear over the concentration range 0.1-10 µg ml⁻¹, and detection limits ranged from 13.9 to 28.5 ng ml⁻¹. Precision calculated at three different concentration levels in plasma was included in the range 0.1-6.8% RSD. Recoveries of the five drugs were all higher than 84% on average. Finally the proposed method was successfully applied to 22 plasma samples from heroin, cocaine and/or methadone users, and the most frequently detected drug was benzoylecgonine, followed by methadone, cocaine and morphine.

  9. Microwave-assisted ionic liquid homogeneous liquid-liquid microextraction coupled with high performance liquid chromatography for the determination of anthraquinones in Rheum palmatum L.

    Science.gov (United States)

    Wang, Zhibing; Hu, Jianxue; Du, Hongxia; He, Shuang; Li, Qing; Zhang, Hanqi

    2016-06-01

    The microwave-assisted ionic liquid homogeneous liquid-liquid microextraction (MA-IL-HLLME) coupled with high performance liquid chromatography with diode array detection (HPLC-DAD) was developed for the determination of anthraquinones, including aloe-emodin, emodin, chrysophanol and physcion in root of Rheum palmatum L. Several experimental parameters influencing the extraction efficiency, including amount of sample, type and volume of ionic liquid, volume and pH value of extraction medium, microwave power and extraction time, concentration of NH4PF6 as well as centrifugal condition were optimized. When 140μL of ionic liquid ([C8MIM][BF4]) was used as an extraction solvent, target analytes can be extracted from sample matrix in one minute with the help of microwave irradiation. The MA-IL-HLLME is simple and quick. The calibration curves exhibited good linear relationship (r>0.9984). The limits of detection and quantification were in the range of 0.015-0.026 and 0.051-0.088μgmL(-1), respectively. The spiked recovery for each analyte was in the range of 81.13-93.07% with relative standard deviations lower than 6.89%. The present method is free of volatile organic solvents, and represents lower expenditures of sample, extraction time and solvent, compared with ultrasonic and heat reflux extraction. The results indicated that the present method can be successfully applied to the determination of anthraquinones in medicinal plant.

  10. [Determination of five triazine herbicides in infant milk powder by high performance liquid chromatography coupled with ionic liquid-based homogeneous liquid-liquid microextraction].

    Science.gov (United States)

    Zhang, Liyuan; Yao, Di; Li, Na; Zhang, Hanqi; Yu, Aimin

    2015-07-01

    A high performance liquid chromatography coupled with homogeneous liquid-liquid microextraction was developed for the determination of five triazine herbicides in infant milk powders. The ionic liquid was used as microextraction solvent. The separation of the herbicides was performed on an Eclipse XDB-C18 column using acetonitrile and water as mobile phases in gradient mode. The effects of homogeneous liquid-liquid extraction conditions on the experimental results were investigated in detail. Under the optimized experimental conditions, the calibration curves for determining the analytes were linear and the correlation coefficients were ≥ 0.9992. The limits of detection for cyanazine, desmetryn, terbumeton, terbuthylazine and dimethametryn were 12.1, 13.8, 11.8, 14.6 and 13.7 μg/kg, respectively. The recoveries of the analytes spiked in four infant milk powders ranged from 92.2% to 103.2% and the relative standard deviations were lower than 6%. This method is sensitive, simple, and suitable for the determination of triazine herbicides in milk powder samples.

  11. Identification of Explosives from Porous Materials: Applications Using Reverse Phase High Performance Liquid Chromatography and Gas Chromatography

    Energy Technology Data Exchange (ETDEWEB)

    C.J. Miller; G. Elias; N.C. Schmitt; C. Rae

    2010-06-01

    High performance liquid chromatography and gas chromatography techniques are well documented and widely used for the detection of trace explosives from organic solvents. These techniques were modified to specifically identify and quantify explosives extracted from various materials taken from people who had recently handled explosives. Documented techniques were modified to specifically detect and quantify RDX, TNT, and PETN from denim, colored flannel, vinyl, and canvas extracted in methanol using no sample cleanup prior to analysis. The methanol extracts were injected directly into several different column types and analyzed by HPLC-UV and/or GC-ECD. This paper describes general screening methods that were used to determine the presence of explosives in unknown samples and techniques that have been optimized for quantification of each explosive from the substrate extracts.

  12. Liquid-phase reactions induced by atmospheric pressure glow discharge with liquid electrode

    Science.gov (United States)

    Tochikubo, Fumiyoshi; Shirai, Naoki; Uchida, Satoshi

    2014-12-01

    We experimentally investigated some of the initial reactions in a liquid induced by electron or positive-ion irradiation from an atmospheric-pressure dc glow discharge in contact with the liquid. We used an H-shaped glass reactor to observe the effects of electron irradiation and positive-ion irradiation on the liquid-phase reaction separately and simultaneously. Aqueous solutions of NaCl, AgNO3, HAuCl4, and FeCl2 are used as the electrolyte. Solutions of AgNO3 and HAuCl4 are used for the generation of Ag and Au nanoparticles, respectively. Solution of FeCl2 is used for the generation of ferromagnetic particles. Experimental results showed that electron irradiation of the liquid surface generates OH- in water and that positive-ion irradiation of the liquid surface generates H+ in water even without the dissolution of gas-phase nitrogen oxide. A possible reaction process is qualitatively discussed. We also showed that the control of reductive and oxidative environment in the liquid is possible not only by the gas composition for the plasma generation but also by the liquid composition.

  13. Analysis of nitroguanidine in Aqueous Solutions by HPLC (High Performance Liquid Chromatography) with electrochemical Detection and Voltammetry

    Science.gov (United States)

    1987-04-01

    The nitroguanidine was analyzed by high performance liquid chromatography (HPLC) with electrochemical detection at a hanging miercury drop electrode...previously reported on the application of solid sorbent collection techniques to the analysis of several explosives in water by high performance liquid chromatography (HPLC

  14. Application in pesticide analysis: Liquid chromatography - A review of the state of science for biomarker discovery and identification

    Science.gov (United States)

    Book Chapter 18, titled Application in pesticide analysis: Liquid chromatography - A review of the state of science for biomarker discovery and identification, will be published in the book titled High Performance Liquid Chromatography in Pesticide Residue Analysis (Part of the C...

  15. Identifying Ca2+-Binding Sites in Proteins by Liquid Chromatography-Mass Spectrometry Using Ca2+-Directed Dissociations

    NARCIS (Netherlands)

    Jamalian, Azadeh; Sneekes, Evert-Jan; Wienk, Hans; Dekker, Lennard J. M.; Ruttink, Paul J. A.; Ursem, Mario; Luider, Theo M.; Burgers, Peter C.

    2014-01-01

    Here we describe a new method to identify calcium-binding sites in proteins using high-resolution liquid chromatography-mass spectrometry in concert with calcium-directed collision-induced dissociations. Our method does not require any modifications to the liquid chromatography-mass spectrometry app

  16. DETERMINATION OF CARBENDAZIM IN WATER BY HIGH-PERFORMANCE IMMUNOAFFINITY CHROMATOGRAPHY ON-LINE WITH HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY WITH DIODE-ARRAY OR MASS SPECTROMETRIC DETECTION

    Science.gov (United States)

    An automated method for the determination of carbendazim in water that combines high-performance immunoaffinity chromatography (HPIAC), high-performance liquid chromatography (HPLC) in the reversed-phase mode, and detection by either UV-Vis diode array detector (DAD) spectroscopy...

  17. Comparison of gas chromatography/isotope ratio mass spectrometry and liquid chromatography/isotope ratio mass spectrometry for carbon stable-isotope analysis of carbohydrates

    NARCIS (Netherlands)

    Moerdijk-Poortvliet, T.C.W.; Schierbeek, H.; Houtekamer, M.; van Engeland, T.; Derrien, D.; Stal, L.J.; Boschker, H.T.S.

    2015-01-01

    We compared gas chromatography/isotope ratio mass spectrometry (GC/IRMS) and liquid chromatography/isotope ratio mass spectrometry (LC/IRMS) for the measurement of d13C values in carbohydrates. Contrary to GC/IRMS, no derivatisation is needed for LC/IRMS analysis of carbohydrates. Hence, although

  18. The analysis of aqueous mixtures using liquid chromatography-electrospray mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Steven [Iowa State Univ., Ames, IA (United States)

    1999-02-12

    The focus of this dissertation is the use of chromatographic methods coupled with electrospray mass spectrometry (ES-MS) for the determination of both organic and inorganic compounds in aqueous solutions. The combination of liquid chromatography (LC) methods and ES-MS offers one of the foremost methods for determining compounds in complex aqueous solutions. In this work, LC-ES-MS methods are devised using ion exclusion chromatography, reversed phase chromatography, and ion exchange chromatography, as well as capillary electrophoresis (CE). For an aqueous sample, these LC-ES-MS and CE-ES-MS techniques require no sample preparation or analyte derivatization, which makes it possible to observe a wide variety of analytes as they exist in solution. The majority of this work focuses on the use of LC-ES-MS for the determination of unknown products and intermediates formed during electrochemical incineration (ECI), an experimental waste remediation process. This report contains a general introduction to the project and the general conclusions. Four chapters have been removed for separate processing. Titles are: Chapter 2: Determination of small carboxylic acids by ion exclusion chromatography with electrospray mass spectrometry; Chapter 3: Electrochemical incineration of benzoquinone in aqueous media using a quaternary metal oxide electrode in the absence of a soluble supporting electrolyte; Chapter 4: The determination of electrochemical incineration products of 4-chlorophenol by liquid chromatography-electrospray mass spectrometry; and Chapter 5: Determination of small carboxylic acids by capillary electrophoresis with electrospray mass spectrometry.

  19. Liquid chromatography and supercritical fluid chromatography as alternative techniques to gas chromatography for the rapid screening of anabolic agents in urine.

    Science.gov (United States)

    Desfontaine, Vincent; Nováková, Lucie; Ponzetto, Federico; Nicoli, Raul; Saugy, Martial; Veuthey, Jean-Luc; Guillarme, Davy

    2016-06-17

    This work describes the development of two methods involving supported liquid extraction (SLE) sample treatment followed by ultra-high performance liquid chromatography or ultra-high performance supercritical fluid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS and UHPSFC-MS/MS) for the screening of 43 anabolic agents in human urine. After evaluating different stationary phases, a polar-embedded C18 and a diol columns were selected for UHPLC-MS/MS and UHPSFC-MS/MS, respectively. Sample preparation, mobile phases and MS conditions were also finely tuned to achieve highest selectivity, chromatographic resolution and sensitivity. Then, the performance of these two methods was compared to the reference routine procedure for steroid analyses in anti-doping laboratories, which combines liquid-liquid extraction (LLE) followed by gas chromatography coupled to tandem mass spectrometry (GC-MS/MS). For this purpose, urine samples spiked with the compounds of interest at five different concentrations were analyzed using the three analytical platforms. The retention and selectivity of the three techniques were very different, ensuring a good complementarity. However, the two new methods displayed numerous advantages. The overall procedure was much faster thanks to high throughput SLE sample treatment using 48-well plates and faster chromatographic analysis. Moreover, the highest sensitivity was attained using UHPLC-MS/MS with 98% of the doping agents detected at the lowest concentration level (0.1ng/mL), against 76% for UHPSFC-MS/MS and only 14% for GC-MS/MS. Finally, the weakest matrix effects were obtained with UHPSFC-MS/MS with 76% of the analytes displaying relative matrix effect between -20 and 20%, while the GC-MS/MS reference method displayed very strong matrix effects (over 100%) for all of the anabolic agents.

  20. DETERMINATION OF ENZYME-ACTIVITY BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY

    NARCIS (Netherlands)

    WELLING, GW; SCHEFFER, AJ; WELLINGWESTER, S

    1994-01-01

    The application of high-performance liquid chromatography (HPLC) in the study of enzymatic reactions is reviewed. The rationale for using HPLC is given and whether the components of the reaction mixture should be derivatized prior to or after HPLC. An alphabetical list of enzymes assayed by HPLC is

  1. Determination of daminozide in apples and apple leaves by liquid chromatography-mass spectrometry

    NARCIS (Netherlands)

    Mol, H.G.J.; Dam, R.C.J. van; Vreeken, R.J.; Steijger, O.M.

    1999-01-01

    A straightforward and efficient method was developed for the determination of intact daminozide in apples and apple leaves. After extraction with methanol and a clean-up step using a graphitized carbon cartridge, the extract was analysed by ion-trap liquid chromatography-tandem mass spectrometry (LC

  2. High-performance liquid chromatography of rat and mouse islet polypeptides

    DEFF Research Database (Denmark)

    Linde, S; Hansen, B; Welinder, B S

    1990-01-01

    After preparative high-performance liquid chromatography of mouse islet culture medium, concentrated on disposable C18 cartridges (Sep-Pak), an unexpected insulin immunoreactive peak eluting earlier than mouse insulin I and II was detected. Molecular mass determination by mass spectrometry...

  3. Going Beyond, Going Further: An Inexpensive Experiment for the Introduction of High Performance Liquid Chromatography.

    Science.gov (United States)

    Bidlingmeyer, Brian A.; Warren, F. Vincent, Jr.

    1984-01-01

    Background information, materials needed, laboratory procedures, and typical results are provided for five high performance liquid chromatography experiments (three isocratic and two step gradient separations). Suggestions for further experimentation are also provided, including quantitative determinations and separation of charged solutes. (JN)

  4. Quantitative separation of tetralin hydroperoxide from its decomposition products by high performance liquid chromatography

    Science.gov (United States)

    Worstell, J. H.; Daniel, S. R.

    1981-01-01

    A method for the separation and analysis of tetralin hydroperoxide and its decomposition products by high pressure liquid chromatography has been developed. Elution with a single, mixed solvent from a micron-Porasil column was employed. Constant response factors (internal standard method) over large concentration ranges and reproducible retention parameters are reported.

  5. Extraction and Purification of Glucoraphanin by Preparative High-Performance Liquid Chromatography (HPLC)

    Science.gov (United States)

    Lee, Iris; Boyce, Mary C.

    2011-01-01

    A student activity that focuses on the isolation of glucoraphanin from broccoli using preparative high-performance liquid chromatography (HPLC) is presented here. Glucoraphanin is a glucosinolate, whose byproducts are known to possess anticancer properties. It is present naturally at high levels in broccoli and other "Brassica" vegetables. This…

  6. High-Performance Liquid Chromatography in the Undergraduate Chemical Engineering Laboratory

    Science.gov (United States)

    Frey, Douglas D.; Guo, Hui; Karnik, Nikhila

    2013-01-01

    This article describes the assembly of a simple, low-cost, high-performance liquid chromatography (HPLC) system and its use in the undergraduate chemical engineering laboratory course to perform simple experiments. By interpreting the results from these experiments students are able to gain significant experience in the general method of…

  7. DETERMINATION OF CHLOROPHENOLS, NITROPHENOLS, AND METHYLPHENOLS IN GROUND-WATER SAMPLES USING HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

    Science.gov (United States)

    A high performance liquid chromatography (HPLC) method was developed to quantitatively determine phenolic compounds and their isomers in aqueous samples. The HPLC method can analyze a mixture of 15 contaminants in the same analytical run with an analysis time of 25 minutes. The...

  8. Determination of low molecular weight thiols using monobromobimane fluorescent labeling and high-performance liquid chromatography

    Science.gov (United States)

    Fahey, Robert C.; Newton, Gerald L.

    1988-01-01

    Methods are described for the preparation and high-performance liquid chromatography (HPLC) analysis of monobromobimane derivatives of low molecular weight thiols in extracts of biological samples. Typical problems encountered in the development and application of these methods are discussed. Analysis of mung bean extract is used as an example.

  9. High Performance Liquid Chromatography of Some Analgesic Compounds: An Instrumental Analysis Experiment.

    Science.gov (United States)

    Haddad, Paul; And Others

    1983-01-01

    Background information, procedures, and results are provided for an experiment demonstrating techniques of solvent selection, gradient elution, pH control, and ion-pairing in the analysis of an analgesic mixture using reversed-phase liquid chromatography on an octadecylsilane column. Although developed using sophisticated/expensive equipment, less…

  10. Sugar Determination in Foods with a Radially Compressed High Performance Liquid Chromatography Column.

    Science.gov (United States)

    Ondrus, Martin G.; And Others

    1983-01-01

    Advocates use of Waters Associates Radial Compression Separation System for high performance liquid chromatography. Discusses instrumentation and reagents, outlining procedure for analyzing various foods and discussing typical student data. Points out potential problems due to impurities and pump seal life. Suggests use of ribose as internal…

  11. Simultaneous quantitative analysis of metabolites using ion-pair liquid chromatography-electrospray ionization mass spectrometry

    NARCIS (Netherlands)

    Coulier, L.; Bas, R.; Jespersen, S.; Verheij, E.; Werf, M.J. van der; Hankemeier, T.

    2006-01-01

    We have developed an analytical method, consisting of ion-pair liquid chromatography coupled to electrospray ionization mass spectrometry (IP-LC-ESI-MS), for the simultaneous quantitative analysis of several key classes of polar metabolites, like nucleotides, coenzyme A esters, sugar nucleotides, an

  12. Experimental hydrophobicity parameters of perfluorinated alkylated substances from reversed-phase high performance liquid chromatography

    NARCIS (Netherlands)

    de Voogt, P.; Zurano, L.; Serné, P.; Haftka, J.J.H.

    2012-01-01

    Capacity factors of perfluorinated alkylated substances were obtained from isocratic reversed-phase high-performance liquid chromatography-mass spectrometry experiments at different organic modifier strengths of the mobile phase. The resulting capacity factor v. modifier strengths plots were extrapo

  13. Analysis of Currently Available Analgesic Tablets by Modern Liquid Chromatography: An Undergraduate Laboratory Introduction to HPLC.

    Science.gov (United States)

    Kagel, R. A.; Farwell, S. O.

    1983-01-01

    Background information, procedures, and results, are provided for an undergraduate experiment in which analgesic tablets are analyzed using liquid chromatography. The experiment, an improved, modified version of the Waters Associates Inc. experiment, is simple to prepare, requiring little glassware and minimal sample manipulation by students. (JN)

  14. Sensitive, Preclinical Detection of Prions in Brain by nanospray liquid chromatography/tandem mass spectrometry

    Science.gov (United States)

    More sensitive detection of prions in brain is important because it would allow early detection of disease in young animals and assure a safer food supply. We quantitated the amount of proteinase K-resistant prion protein (PrP 27-30) by use of nano-scale liquid chromatography coupled to a tandem ma...

  15. Sorption of catechins under conditions of reverse-phase high-efficiency liquid chromatography

    Science.gov (United States)

    Shafigulin, R. V.; Egorova, K. V.; Bulanova, A. V.

    2010-08-01

    The physico-chemical principles of catechin sorption from various polar solvents onto silica gel modified with octadecyl groups were studied. Thermodynamic characteristics of the sorption were calculated, and the applicability of different models of retention was demonstrated for catechins under the conditions of reverse-phase high-efficiency liquid chromatography.

  16. The role of liquid chromatography-tandem mass spectrometry in the clinical laboratory

    NARCIS (Netherlands)

    van den Ouweland, Johannes M. W.; Kema, Ido P.

    2012-01-01

    Liquid chromatography coupled to mass spectrometry (LC-MS/MS) is increasingly used as a routine methodology in clinical laboratories for the analysis of low molecular weight molecules. The high specificity in combination with high sensitivity and multi-analyte potential makes it an attractive comple

  17. Simulated Moving Bed Chromatography: Separation and Recovery of Sugars and Ionic Liquid from Biomass Hydrolysates

    Science.gov (United States)

    Caes, Benjamin R.; Van Oosbree, Thomas R.; Lu, Fachuang; Ralph, John; Maravelias, Christos T.

    2015-01-01

    Simulated moving bed chromatography, a continuous separation method, enables the nearly quantitative recovery of sugar products and ionic liquid solvent from chemical hydrolysates of biomass. The ensuing sugars support microbial growth, and the residual lignin from the process is intact. PMID:23939991

  18. An Advanced, Interactive, High-Performance Liquid Chromatography Simulator and Instructor Resources

    Science.gov (United States)

    Boswell, Paul G.; Stoll, Dwight R.; Carr, Peter W.; Nagel, Megan L.; Vitha, Mark F.; Mabbott, Gary A.

    2013-01-01

    High-performance liquid chromatography (HPLC) simulation software has long been recognized as an effective educational tool, yet many of the existing HPLC simulators are either too expensive, outdated, or lack many important features necessary to make them widely useful for educational purposes. Here, a free, open-source HPLC simulator is…

  19. Characterization of Pentachlorophenol in Soil by Liquid Chromatography-Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    JIN Mi-cong; WANG Biao

    2004-01-01

    A simple, accurate and sensitive method for characterization of pentachlorophenol in soil was presented. The method included Soxhlet extraction using extracting agent of methanol/water/triethylamine (80∶20∶2), decontamination using solid-phase extraction (SPE) column and characterization by liquid chromatography-mass spectrometry (LCMS). The developed analytical method was successfully used to the determination of pentachlorophenol in soil samples.

  20. High-Performance Liquid Chromatography in the Undergraduate Chemical Engineering Laboratory

    Science.gov (United States)

    Frey, Douglas D.; Guo, Hui; Karnik, Nikhila

    2013-01-01

    This article describes the assembly of a simple, low-cost, high-performance liquid chromatography (HPLC) system and its use in the undergraduate chemical engineering laboratory course to perform simple experiments. By interpreting the results from these experiments students are able to gain significant experience in the general method of…

  1. An on-line high performance liquid chromatography-crocin bleaching assay for detection of antioxidants

    NARCIS (Netherlands)

    Bountagkidou, O.; Klift, van der E.J.C.; Tsimidou, M.Z.; Ordoudi, S.A.; Beek, van T.A.

    2012-01-01

    An on-line HPLC (high performance liquid chromatography) method for the rapid screening of individual antioxidants in mixtures was developed using crocin as a substrate (i.e. oxidation probe) and 2,2'-azobis(2-amidinopropane dihydrochloride (AAPH)) in phosphate buffer (pH 7.5) as a radical generator

  2. Determination of Peroxide-Based Explosives Using Liquid Chromatography with On-Line Infrared Detection

    NARCIS (Netherlands)

    Schulte-Ladbeck, Rasmus; Edelmann, Andrea; Quintas, Guillermo; Lendl, Bernhard; Karst, U.

    2006-01-01

    A nondestructive analytical method for peroxide-based explosives determination in solid samples is described. Reversed-phase high-performance liquid chromatography in combination with on-line Fourier transform infrared (FT-IR) detection is used for the analysis of triacetonetriperoxide (TATP) and

  3. Isotope Fractionation in Methane Reactions Studied by Gas Chromatography and Liquid Scintillation

    DEFF Research Database (Denmark)

    Andersen, Bertel Lohmann; Bidoglio, G.; Leip, A.

    1997-01-01

    Determination of C-14-marked methane by gas chromatography and liquid scintillation counting is shown to be useful in studies of isotope effects. Data on the specific activity is used to separate the contributions of (CH4)-C-14, and (CH4)-C-12 to the gas-chromatographic peak area. As an application...

  4. Simultaneous determination of seven flavonoids in Epimedium by liquid chromatography-tandem mass spectrometry method

    Institute of Scientific and Technical Information of China (English)

    Cai Sheng Wu; Bao Lin Guo; Yu Xin Sheng; Jin Lan Zhang

    2008-01-01

    In this paper, a sensitive and specific liquid chromatography-electrospray ionisation-mass spectrometry (LC-ESI-MS) method has been developed and validated for the identification and determination of seven flavonoids, namely epimedin A, epimedin B, epimedin C, icariin, sagittatoside B, 2"-0-rhamnosyl icariside II, and baohuoside I in Epimedium from different sources.

  5. The Separation and Identification of Straight Chain Hydrocarbons: An Experiment Using Gas-Liquid Chromatography.

    Science.gov (United States)

    Benson, G. A.

    1982-01-01

    An experiment using gas-liquid chromatography is discussed, introducing the student to concept of dead volume and its measurement, idea and use of an internal reference compound, and to linear relationship existing between measurements of a separation on two different stationary phases. (Author/SK)

  6. Alternative sample-introduction technique to avoid breakthrough in gradient-elution liquid chromatography of polymers

    NARCIS (Netherlands)

    Reingruber, E.; Bedani, F.; Buchberger, W.; Schoenmakers, P.

    2010-01-01

    Gradient-elution liquid chromatography (GELC) is a powerful tool for the characterization of synthetic polymers. However, gradient-elution chromatograms often suffer from breakthrough phenomena. Breakthrough can be averted by using a sample solvent as weak as the mobile phase. However, this approach

  7. Deformation and degradation of polymers in ultra-high-pressure liquid chromatography

    NARCIS (Netherlands)

    Uliyanchenko, E.; van der Wal, S.; Schoenmakers, P.J.

    2011-01-01

    Ultra-high-pressure liquid chromatography (UHPLC) using columns packed with sub-2 μm particles has great potential for separations of many types of complex samples, including polymers. However, the application of UHPLC for the analysis of polymers meets some fundamental obstacles. Small particles an

  8. High throughput pyrogenic carbon (biochar) characterisation and quantification by liquid chromatography

    NARCIS (Netherlands)

    Cerqueira, W.V.; Rittl, T.F.; Novotny, E.H.; Pereira Netto, A.D.

    2015-01-01

    Characterisation and quantification of the carbonaceous polyaromatic structure of pyrogenic carbon (PyC) are of paramount importance to evaluate the role of PyC in soil carbon sequestration. A new method of rapid resolution liquid chromatography with UV diode array detection (RRLC-UV-DAD) was dev

  9. Determination of organophosphorus acids by thermo-spray liquid chromatography-mass spectrometry

    NARCIS (Netherlands)

    Wils, E.R.J.; Hulst, A.G.

    1988-01-01

    The determination of thirteen organophosphorus acids, hydrolysis products of nerve agents and pesticides, by a combination of ion-pair liquid chromatography on a reversed-phase C18 column and thermospray mass spectrometry was investigated. Ammonium acetate and three tetraalkylammonium salts with dif

  10. Analysis of Currently Available Analgesic Tablets by Modern Liquid Chromatography: An Undergraduate Laboratory Introduction to HPLC.

    Science.gov (United States)

    Kagel, R. A.; Farwell, S. O.

    1983-01-01

    Background information, procedures, and results, are provided for an undergraduate experiment in which analgesic tablets are analyzed using liquid chromatography. The experiment, an improved, modified version of the Waters Associates Inc. experiment, is simple to prepare, requiring little glassware and minimal sample manipulation by students. (JN)

  11. Extraction and Purification of Glucoraphanin by Preparative High-Performance Liquid Chromatography (HPLC)

    Science.gov (United States)

    Lee, Iris; Boyce, Mary C.

    2011-01-01

    A student activity that focuses on the isolation of glucoraphanin from broccoli using preparative high-performance liquid chromatography (HPLC) is presented here. Glucoraphanin is a glucosinolate, whose byproducts are known to possess anticancer properties. It is present naturally at high levels in broccoli and other "Brassica" vegetables. This…

  12. Determination of Peroxide-Based Explosives Using Liquid Chromatography with On-Line Infrared Detection

    NARCIS (Netherlands)

    Schulte-Ladbeck, Rasmus; Edelmann, Andrea; Quintas, Guillermo; Lendl, Bernhard; Karst, Uwe

    2006-01-01

    A nondestructive analytical method for peroxide-based explosives determination in solid samples is described. Reversed-phase high-performance liquid chromatography in combination with on-line Fourier transform infrared (FT-IR) detection is used for the analysis of triacetonetriperoxide (TATP) and he

  13. Benzoin Condensation: Monitoring a Chemical Reaction by High-Pressure Liquid Chromatography

    Science.gov (United States)

    Bhattacharya, Apurba; Purohit, Vikram C.; Bellar, Nicholas R.

    2004-01-01

    High-pressure liquid chromatography (HPLC) is the preferred method of separating a variety of materials in complex mixtures such as pharmaceuticals, polymers, soils, food products and biological fluids and is also considered to be a powerful analytical tool in both academia and industry. The use of HPLC analysis as a means of monitoring and…

  14. Gold nanoparticle decorated graphene oxide/silica composite stationary phase for high-performance liquid chromatography.

    Science.gov (United States)

    Liang, Xiaojing; Wang, Xusheng; Ren, Haixia; Jiang, Shengxiang; Wang, Licheng; Liu, Shujuan

    2014-06-01

    In the initial phase of this study, graphene oxide (GO)/silica was fabricated by assembling GO onto the silica particles, and then gold nanoparticles (GNPs) were used to modify the GO/silica to prepare a novel stationary phase for high-performance liquid chromatography. The new stationary phase could be used in both reversed-phase chromatography and hydrophilic interaction liquid chromatography modes. Good separations of alkylbenzenes, isomerides, amino acids, nucleosides, and nucleobases were achieved in both modes. Compared with the GO/silica phase and GNPs/silica phase, it is found that except for hydrophilicity, large π-electron systems, hydrophobicity, and coordination functions, this new stationary phase also exhibited special separation performance due to the combination of 2D GO with zero-dimensional GNPs.

  15. Determination of alkyl amines in atmospheric aerosol particles: a comparison of gas chromatography-mass spectrometry and ion chromatography approaches

    Directory of Open Access Journals (Sweden)

    R.-J. Huang

    2014-03-01

    Full Text Available In recent years low molecular weight alkyl amines have been recognized to play an important role in particle formation and growth in the lower atmosphere. However, major uncertainties are associated with their atmospheric processes, sources and sinks, mostly due to the lack of ambient measurements and the difficulties in accurate quantification of alkyl amines at trace level. In this study, we present the evaluation and optimization of two analytical approaches, i.e., gas chromatography-mass spectrometry (GC-MS and ion chromatography (IC, for the determination of alkyl amines in aerosol particles. Alkyl amines were converted to carbamates through derivatization with isobutyl chloroformate for GC-MS determination. A set of parameters affecting the analytical performances of the GC-MS approach, including reagent amount, reaction time and pH value, was evaluated and optimized. The accuracy is 84.3–99.1%, and the limits of detection obtained are 1.8–3.9 pg. For the IC approach, a solid phase extraction (SPE column was used to separate alkyl amines from interfering cations before IC analysis. 1–2% (v/v of acetone (or 2–4% (v/v of acetonitrile was added to the eluent to improve the separation of alkyl amines on the IC column. The limits of detection obtained are 2.1–15.9 ng and the accuracy is 55.1–103.4%. The lower accuracy can be attributed to evaporation losses of amines during the sample concentration procedure. Measurements of ambient aerosol particle samples collected in Hong Kong show that the GC-MS approach is superior to the IC approach for the quantification of primary and secondary alkyl amines due to its lower detection limits and higher accuracy.

  16. Gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-mass spectrometry (LC-MS) in toxicological analysis. Studies on the detection of clobenzorex and its metabolites within a systematic toxicological analysis procedure by GC-MS and by immunoassay and studies on the detection of alpha- and beta-amanitin in urine by atmospheric pressure ionization electrospray LC-MS.

    Science.gov (United States)

    Maurer, H H; Kraemer, T; Ledvinka, O; Schmitt, C J; Weber, A A

    1997-02-07

    GC-MS is the method of choice for toxicological analysis of toxicants volatile in GC while non-volatile and/or thermally labile toxicants need LC-MS for their determination. Studies are presented on the toxicological detection of the amphetamine-like anorectic clobenzorex in urine by GC-MS after acid hydrolysis, extraction and acetylation and by fluorescence polarization immunoassay (FPIA, TDx (meth)amphetamine II). After ingestion of 60 mg of clobenzorex, the parent compound and/or its metabolites could be detected by GC-MS for up to 84 h or by FPIA for up to 60 h. Since clobenzorex shows no cross-reactivity with the used immunoassay, the N-dealkylated metabolite amphetamine is responsible for the positive TDx results. The intake of clobenzorex instead of amphetamine can be differentiated by GC-MS detection of hydroxyclobenzorex which is detectable for at least as long as amphetamine. In addition, the described GC-MS procedure allows the simultaneous detection of most of the toxicologically relevant drugs. Furthermore, studies are described on the atmospheric pressure ionization electrospray LC-MS detection of alpha- and beta-amanitin, toxic peptides of amanita mushrooms, in urine after solid-phase extraction on RP-18 columns. Using the single ion monitoring mode with the ions m/z 919 and 920 the amanitins could be detected down to 10 ng/ml of urine which allows us to diagnose intoxications with amanita mushrooms.

  17. Resolution of RNA using high-performance liquid chromatography

    NARCIS (Netherlands)

    Mclaughlin, L.W.; Bischoff, Rainer

    1987-01-01

    High-performance liquid chromatographic techniques can be very effective for the resolution and isolation of nucleic acids. The characteristic ionic (phosphodiesters) and hydrophobic (nucleobases) properties of RNAs can be exploited for their separation. In this respect anion-exchange and reversed-p

  18. Studies on Chromatography Fingerprint of Hongqi by High-performance Liquid Chromatography

    Institute of Scientific and Technical Information of China (English)

    Shi Lan FENG; Fang Di HU; Jian Xiong ZHAO; Jing Wen XU; Li Ren CHEN

    2004-01-01

    Chromatography fingerprint (CFP) of 10 samples of hongqi were studied. 23 common peaks were analyzed, their average similarity was 97.29%. CFP were positioned with main index composition such as formononetin, calycosin and then the contents of index composition were determined. The character and exclusive of CFP of 10 samples of hongqi were clear. CFP and content determination of index composition of hongqi could be used to evaluate the quality of hongqi comprehensively.

  19. Characterization of goat colostrum oligosaccharides by nano-liquid chromatography on chip quadrupole time-of-flight mass spectrometry and hydrophilic interaction liquid chromatography-quadrupole mass spectrometry.

    Science.gov (United States)

    Martín-Ortiz, A; Salcedo, J; Barile, D; Bunyatratchata, A; Moreno, F J; Martin-García, I; Clemente, A; Sanz, M L; Ruiz-Matute, A I

    2016-01-08

    A detailed qualitative and quantitative characterization of goat colostrum oligosaccharides (GCO) has been carried out for the first time. Defatted and deproteinized colostrum samples, previously treated by size exclusion chromatography (SEC) to remove lactose, were analyzed by nanoflow liquid chromatography-quadrupole-time of flight mass spectrometry (Nano-LC-Chip-Q-TOF MS). Up to 78 oligosaccharides containing hexose, hexosamine, fucose, N-acetylneuraminic acid or N-glycolylneuraminic acid monomeric units were identified in the samples, some of them detected for the first time in goat colostra. As a second step, a hydrophilic interaction liquid chromatography coupled to mass spectrometry (HILIC-MS) methodology was developed for the separation and quantitation of the main GCO, both acidic and neutral carbohydrates. Among other experimental chromatographic conditions, mobile phase additives and column temperature were evaluated in terms of retention time, resolution, peak width and symmetry of target carbohydrates. Narrow peaks (wh: 0.2-0.6min) and good symmetry (As: 0.8-1.4) were obtained for GCO using an acetonitrile:water gradient with 0.1% ammonium hydroxide at 40°C. These conditions were selected to quantify the main oligosaccharides in goat colostrum samples. Values ranging from 140 to 315mgL(-1) for neutral oligosaccharides and from 83 to 251mgL(-1) for acidic oligosaccharides were found. The combination of both techniques resulted to be useful to achieve a comprehensive characterization of GCO.

  20. Review of in situ derivatization techniques for enhanced bioanalysis using liquid chromatography with mass spectrometry.

    Science.gov (United States)

    Baghdady, Yehia Z; Schug, Kevin A

    2016-01-01

    Accurate and specific analysis of target molecules in complex biological matrices remains a significant challenge, especially when ultra-trace detection limits are required. Liquid chromatography with mass spectrometry is often the method of choice for bioanalysis. Conventional sample preparation and clean-up methods prior to the analysis of biological fluids such as liquid-liquid extraction, solid-phase extraction, or protein precipitation are time-consuming, tedious, and can negatively affect target recovery and detection sensitivity. An alternative or complementary strategy is the use of an off-line or on-line in situ derivatization technique. In situ derivatization can be incorporated to directly derivatize target analytes in their native biological matrices, without any prior sample clean-up methods, to substitute or even enhance the extraction and preconcentration efficiency of these traditional sample preparation methods. Designed appropriately, it can reduce the number of sample preparation steps necessary prior to analysis. Moreover, in situ derivatization can be used to enhance the performance of the developed liquid chromatography with mass spectrometry-based bioanalysis methods regarding stability, chromatographic separation, selectivity, and ionization efficiency. This review presents an overview of the commonly used in situ derivatization techniques coupled to liquid chromatography with mass spectrometry-based bioanalysis to guide and to stimulate future research.

  1. Highly sensitive detection of melamine based on reversed phase liquid chromatography mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    WU QingQing; FAN KeXin; SHA Wei; RUAN HongQiang; ZENG Rong; SHIEH ChiaHui

    2009-01-01

    In this work, we developed a highly sensitive method to detect melamine based on reversed phase liquid chromatography mass spectrometry. A mass spectrometry compatible ion pair, heptafluorobu-tyric acid(HFBA), was used to separate melamine by reversed phase liquid chromatography prior to electrospray mass spectrometry. The incorporation of isotope internal standard and multiple reaction monitoring improved the accuracy and linearity of quantification. Based on this strategy, the method limit of quantification was 0.1 ng/g. The limits of quantification were 8 ng/g for liquid milk and 15 ng/g for dry milk powder. This method provided a reproducible and stable approach to sensitive detection and quantification of melamine.

  2. Two-dimensional liquid chromatography analysis of synthetic polymers using fast size exclusion chromatography at high column temperature.

    Science.gov (United States)

    Im, Kyuhyun; Park, Hae-Woong; Lee, Sekyung; Chang, Taihyun

    2009-05-22

    In recent years, two-dimensional liquid chromatography (2D-LC) has been used increasingly for the analysis of synthetic polymers. A 2D-LC analysis provides richer information than a single chromatography analysis at the cost of longer analysis time. The time required for a comprehensive 2D-LC analysis is essentially proportional to the analysis time of the second dimension separation. Many of 2D-LC analyses of synthetic polymers have employed size exclusion chromatography (SEC) for the second-dimension analysis due to the relatively short analysis time in addition to the wide use in the polymer analysis. Nonetheless, short SEC columns are often used for 2D-LC analyses to reduce the separation time, which inevitably deteriorates the resolution. In this study, we demonstrated that high temperature SEC can be employed as an efficient second-LC in the 2D-LC separation of synthetic polymers. By virtue of high temperature operation (low solvent viscosity and high diffusivity of the polymer molecules), a normal length SEC column can be used at high flow rate with little loss in resolution.

  3. Hyphenated and comprehensive liquid chromatography × gas chromatography-mass spectrometry for the identification of Mycobacterium tuberculosis.

    Science.gov (United States)

    Mourão, Marta P B; Denekamp, Ilse; Kuijper, Sjoukje; Kolk, Arend H J; Janssen, Hans-Gerd

    2016-03-25

    Tuberculosis is one of the world's most emerging public health problems, particularly in developing countries. Chromatography based methods have been used to tackle this epidemic by focusing on biomarker detection. Unfortunately, interferences from lipids in the sputum matrix, particularly cholesterol, adversely affect the identification and detection of the marker compounds. The present contribution describes the serial combination of normal phase liquid chromatography (NPLC) with thermally assisted hydrolysis and methylation followed by gas chromatography-mass spectrometry (THM-GC-MS) to overcome the difficulties of biomarker evaluation. The in-series combination consists of an LC analysis where fractions are collected and then transferred to the THM-GC-MS system. This was either done with comprehensive coupling, transferring all the fractions, or with hyphenated interfacing, i.e. off-line multi heart-cutting, transferring only selected fractions. Owing to the high sensitivity and selectivity of LC as a sample pre-treatment method, and to the high specificity of the MS as a detector, this analytical approach, NPLC × THM-GC-MS, is extremely sensitive. The results obtained indicate that this analytical set-up is able to detect down to 1 × 10(3) mycobacteria/mL of Mycobacterium tuberculosis strain 124, spiked in blank sputum samples. It is a powerful analytical tool and also has great potential for full automation. If further studies demonstrate its usefulness when applied blind in real sputum specimens, this technique could compete with the current smear microscopy in the early diagnosis of tuberculosis.

  4. Separation of carbohydrates using hydrophilic interaction liquid chromatography.

    Science.gov (United States)

    Fu, Qing; Liang, Tu; Li, Zhenyu; Xu, Xiaoyong; Ke, Yanxiong; Jin, Yu; Liang, Xinmiao

    2013-09-20

    A strategy was developed to rapidly evaluate chromatographic properties of hydrophilic interaction chromatography (HILIC) columns for separating carbohydrates. Seven HILIC columns (Silica, Diol, TSK Amide-80, XAmide, Click Maltose, Click β-CD, and Click TE-Cys columns) were evaluated by using three monosaccharide and seven disaccharides as probes. The influence of column temperature on the peak shape and tautomerization of carbohydrates, as well as column selectivity were investigated. The influence of surface charge property on the retention was also studied by using glucose, glucuronic acid, and glucosamine, which indicated that buffer salt concentration and pH value in mobile phase was necessary to control the ionic interactions between ionic carbohydrates and HILIC columns. According to evaluation results, the XAmide column was selected as an example to establish experimental schemes for separation of complex mixtures of oligosaccharide.

  5. Liquid chromatography-tandem mass spectrometric assay for the tyrosine kinase inhibitor afatinib in mouse plasma using salting-out liquid-liquid extraction

    NARCIS (Netherlands)

    Sparidans, Rolf W; van Hoppe, Stephanie; Rood, Johannes J M; Schinkel, Alfred H; Schellens, Jan H M; Beijnen, Jos H

    2016-01-01

    A quantitative bioanalytical liquid chromatography-tandem mass spectrometric (LC-MS/MS) assay for afatinib, an irreversible inhibitor of the ErbB (erythroblastic leukemia viral oncogene homolog) tyrosine kinase family, was developed and validated. Plasma samples were pre-treated using salting-out as

  6. Isolation and purification of uremic middle molecules by multi-step liquid chromatography

    Institute of Scientific and Technical Information of China (English)

    储结根; 刘晓航; 袁直; 何炳林

    2002-01-01

    Isolation and comparison of uremic sera and urine and normal sera and urine were performed by gel permeation chromatography, anion exchange chromatography and reversed-phase high performance liquid chromatography. Two uremic middle molecular fractions (A and B) were obtained from uremic sera and urine and normal urine by gel permeation chromatography, but not from normal sera. The anion exchange chromatographic results of fraction A from different origins demonstrate that subfraction A-3 could be excreted in urine by healthy subject, but accumulated in uremic serum for renal failure of patient with uremia. After desalinization subfraction A-3 was analyzed by MALDI-TOF-MS. The results show that subfraction A-3 consists of six compounds with molecular weight 839, 873, 1007.94, 1106, 1680 and 2015 respectively. Finally, by reversed-phase high performance liquid chromatography, subfraction A-3 was further resolved into six independent fractions. Thus, the isolation and purification of six middle molecular compounds in subfraction A-3 came true by our method.

  7. Characterization of sodium carboxymethyl cellulose by comprehensive two-dimensional liquid chromatography.

    Science.gov (United States)

    Shakun, Maria; Heinze, Thomas; Radke, Wolfgang

    2015-10-05

    Two series of sodium carboxymethyl celluloses (NaCMC) with average degrees of substitution (DS) ranging from 0.45 to 1.55 were synthesized from low molecular mass Avicel cellulose (Avicel samples) and from high molecular mass cotton linters (BWL samples). The samples were characterized by online two-dimensional liquid chromatography using gradient liquid adsorption chromatography in the first and size exclusion chromatography (SEC) in the second dimension. This method allows the simultaneous determination of the chemical composition (DS) and the molar mass distribution within the individual samples. Moreover information was obtained on the dependence of the elution volume in gradient chromatography on molar mass. As expected, evidence for a stronger influence of molar mass on gradient elution volume was found for the low molecular mass NaCMC as compared to the high molecular mass BWL samples. Finally the applicability of the method for the simultaneous separation of blends heterogeneous with respect to chemical composition (DS) and molar mass was demonstrated. Such blends cannot be efficiently separated by either SEC or gradient chromatography alone, nor by simply combining the results of both methods. Only the complete two-dimensional chromatogram can reveal the complexity of such blends, since it reveals the correlations between molar mass and chemical composition.

  8. Background vapor from six ionic liquids and the partition coefficients and limits of detection for 10 different analytes in those ionic liquids measured using headspace gas chromatography.

    Science.gov (United States)

    Von Wald, Grant; Albers, David; Cortes, Hernan; McCabe, Terry

    2008-08-01

    The concentration and identity of the compounds detected in the vapor above six ionic liquids by headspace gas chromatography (HS-GC) at 100 degrees C are reported. In addition, the partition coefficients for 10 different compounds in these ionic liquids and limits of detection were measured. These results provide quantitative guidance for the application of ionic liquids for HS-GC.

  9. Gas and high-performance liquid chromatography of phenols

    Energy Technology Data Exchange (ETDEWEB)

    Tesarova, E.; Pacakova, V.

    1983-05-01

    Gas (GC) and high-performance liquid chromatographic (HPLC) methods in the analysis of phenols are reviewed. Among the great number of phenolic compounds analyzed, alkylphenols, chlorophenols, dihydroxy-and trihydroxy-benzenes and biphenols are chiefly considered. The advantages and drawbacks of the methods are discussed. Relationships between the structural characteristics of phenols, the stationary phase structure, the mobile phase composition and the retention data are treated. Typical examples of the conditions for GC and HPLC analysis are summarized in tables. 276 references

  10. Rapid analysis of phentolamine by high-performance liquid chromatography.

    Science.gov (United States)

    Webster, Gregory K; Lemmer, Robert R; Greenwald, Steven

    2003-02-01

    A rapid liquid chromatographic method is validated for the quantitative analysis of phentolamine. Phentolamine exists in three forms for this investigation: as a mesylate salt, hydrochloride salt, and free base. In solution, phentolamine dissociates from its salt and is chromatographed as free phentolamine. This validation confirms the analysis of each form, which is simply based upon molar mass differences encountered in weighing. As such, both the United States Pharmacopeia hydrochloride and mesylate standards are used throughout this validation to demonstrate this equivalency. The validation demonstrates that this method may be used to quantitate phentolamine, regardless of its salt form.

  11. Determination of methylphenidate in Calliphorid larvae by liquid-liquid extraction and liquid chromatography mass spectrometry - Forensic entomotoxicology using an in vivo rat brain model

    DEFF Research Database (Denmark)

    Bushby, Sarah K.; Thomas, Nicky; Priemel, Petra A.;

    2012-01-01

    and Calliphorid larvae) by liquid-liquid extraction with recovery of >80%, and quantified using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The LC-MS/MS assay was validated for entomotoxicological use and initially applied to male Sprague-Dawley rats (n=6) that were dosed with MPH (20mg/kg) ante......The aim of this study was to examine the potential forensic utilisation of blowfly larvae (Diptera: Calliphoridae) as an alternative toxicological specimen for the detection of the psychotropic model drug methylphenidate (MPH). MPH was extracted from biological matrices (rat brain, serum...

  12. Quantitation of antioxidants in water samples using ionic liquid dispersive liquid-liquid microextraction followed by high-performance liquid chromatography-ultraviolet detection.

    Science.gov (United States)

    Sobhi, Hamid Reza; Kashtiaray, Amir; Farahani, Hadi; Farahani, Mohammad Reza

    2011-01-01

    A simple and efficient method, ionic liquid-based dispersive liquid-liquid microextraction combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV), has been applied for the extraction and determination of some antioxidants (Irganox 1010, Irganox 1076 and Irgafos 168) in water samples. The microextraction efficiency factors were investigated and optimized: 1-hexyl-3-methylimidazolium hexafluorophosphate [C(6)MIM][PF(6)] (0.06 g) as extracting solvent, methanol (0.5 mL) as disperser solvent without salt addition. Under the selected conditions, enrichment factors up to 48-fold, limits of detection (LODs) of 5.0-10.0 ng/mL and dynamic linear ranges of 25-1500 ng/mL were obtained. A reasonable repeatability (RSD≤11.8%, n=5) with satisfactory linearity (r(2)≥0.9954) of the results illustrated a good performance of the presented method. The accuracy of the method was tested by the relative recovery experiments on spiked samples, with results ranging from 85 to 118%. Finally, the method was successfully applied for determination of the analytes in several real water samples. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Simultaneous determination of seven anticoagulant rodenticides in agricultural products by gel permeation chromatography and liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Saito-Shida, Shizuka; Nemoto, Satoru; Matsuda, Rieko; Akiyama, Hiroshi

    2016-11-01

    A sensitive and reliable method for the simultaneous determination of hydroxycoumarin-type (brodifacoum, bromadiolone, coumatetralyl, and warfarin) and indandione-type (chlorophacinone, diphacinone, and pindone) rodenticides in agricultural products by gel permeation chromatography (GPC) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed. The procedure involved extraction of the rodenticides from samples with acetone, followed by liquid-liquid partitioning with hexane/ethyl acetate (1:1, v/v) and 10% sodium chloride aqueous solution, then cleanup using GPC, and finally, analysis using LC-MS/MS. High recoveries from the GPC column were obtained for all rodenticides tested using a mobile phase of acetone/cyclohexane/triethylamine (400:1600:1, v/v/v). An ODS column, which contains low levels of metal impurities, gave satisfactory peak shapes for both hydroxycoumarin- and indandione-type rodenticides in the LC-MS/MS separation. The average recoveries of rodenticides from eight agricultural foods (apple, eggplant, cabbage, orange, potato, tomato, brown rice, and soybean) fortified at 0.0005-0.001 mg/kg ranged from 76 to 116%, except for bromadiolone in orange (53%) and diphacinone in soybean (54%), and the relative standard deviations ranged from 1 to 16%. The proposed method effectively removed interfering components, such as pigments and lipids, and showed high selectivity. In addition, the matrix effects were negligible for most of the rodenticide/food combinations. The results suggest that the proposed method is reliable and suitable for determining hydroxycoumarin- and indandione-type rodenticides in agricultural products.

  14. Determination of 1-hydroxypyrene in human urine by high-performance liquid chromatography

    DEFF Research Database (Denmark)

    Hansen, Åse Marie; Poulsen, O M; Christensen, J M

    1993-01-01

    A high-performance liquid chromatography (HPLC)/fluorescence method for quantitative analysis of 1-hydroxypyrene in urine was developed. The method validation analysis showed the method to be in analytical control. No significant systematical errors could be demonstrated. The entire run time...... of chromatography was 10 min using isocratic elution (acetonitrile-water, 70:30), and the retention time for 1-hydroxypyrene was 3.5 min. The short run time in combination with the low limit detection (1.37 nmol/L) makes the method potentially applicable for surveillance of pyrene exposure in work environments...

  15. APPLICATIONS OF CERIUM BIS (MONOMYRISTY—LPHOSPHATE)ADSORBENT TO REVERSED PHASE LIQUID CHROMATOGRAPHY

    Institute of Scientific and Technical Information of China (English)

    SuZhengquan; FengHuixia; 等

    1996-01-01

    The tetravalent metal salts of monoalkyl phosphates [M(O3POR)2]are a new kind of stationary phases of Chromatography-homogeneous bonded phases.This paper deals with the application of cerium bis(monomyristylphosphate)as support to reversed phase liquid chromatography.The results show that the best mobil phase is CH3CN:H2O=95:5.The good separation to the mixture containing six aromatic hydrocarbons and the determination of naphthalene in a group samples have been achieved.The regression analysis shows that detect limits,linearities and precision for six aromatic hydrocarbons are good.

  16. Lattice-fluid model for gas-liquid chromatography.

    Science.gov (United States)

    Tao, Y; Wells, P S; Yi, X; Yun, K S; Parcher, J F

    1999-11-01

    Lattice-fluid models describe molecular ensembles in terms of the number of lattice sites occupied by molecular species (r-mers) and the interactions between neighboring molecules. The lattice-fluid model proposed by Sanchez and Lacombe (Macromolecules, 1978;11:1145-1156) was used to model specific retention volume data for a series of n-alkane solutes with n-alkane, polystyrene, and poly(dimethylsiloxane) stationary liquid phases. Theoretical equations were derived for the specific retention volume and also for the temperature dependence and limiting (high temperature) values for the specific retention volume. The model was used to predict retention volumes within 10% for the n-alkanes phases; 22% for polystyrene; and from 20 to 70% for PDMS using no adjustable parameters. The temperature derivative (enthalpy) could be calculated within 5% for all of the solutes in nine stationary liquid phases. The limiting value for the specific retention volume at high temperature (entropy controlled state) could be calculated within 10% for all of the systems. The limiting data also provided a new chromatographic method to measure the size parameter, r, for any chromatographic solute using characteristic and size parameters for the stationary phase only. The calculated size parameters of the solutes were consistent, i.e. independent of the stationary phase and agreed within experimental error with the size parameters previously reported from saturated vapor pressure, latent heat of vaporization or density data.

  17. Separation of tocopherols by nano-liquid chromatography.

    Science.gov (United States)

    Fanali, Salvatore; Camera, Emanuela; Chankvetadze, Bezhan; D'Orazio, Giovanni; Quaglia, Maria Giovanna

    2004-04-16

    Nanoliquid chromatography (nano-LC) was used for the separation of tocopherols (delta-, gamma-, alpha-TOH), alpha-tocopherol acetate (alpha-TOH-Ac) and an antioxidant compound, namely butylated hydroxytoluene (BHT) used to prevent TOHs autoxidation. The separation was carried out in a fused silica capillary of 100 microm I.D. and 375 microm O.D. packed in our laboratory with RP18 silica stationary phase of either 5- or 3-microm diameter (23-cm long). The mobile phase was composed by mixtures of methanol (MeOH), acetonitrile (MeCN) and water. Typical analyses time for the separation of all the five components of the mixture were 6-9 min depending on the composition of the mobile phase. Efficiency and resolution were strongly influenced by the particle diameter and the highest Rs and N/m values were observed using 3-microm RP18 particles. Experiments performed with capillaries packed with 3-microm RP18 particles provided good limit of detection (LOD) and limit of quantification (LOQ) (for delta-, gamma-TOH, alpha-TOH-Ac were 4 and 8 microg/ml, while for alpha-TOH were 6 and 10 microg/ml, respectively). The optimized method was applied to extracts of serum and pharmaceutical preparation containing alpha-TOH and alpha-TOH-Ac.

  18. Quantitative analysis of multiple components based on liquid chromatography with mass spectrometry in full scan mode.

    Science.gov (United States)

    Xu, Min Li; Li, Bao Qiong; Wang, Xue; Chen, Jing; Zhai, Hong Lin

    2016-08-01

    Although liquid chromatography with mass spectrometry in full scan mode can obtain all the signals simultaneously in a large range and low cost, it is rarely used in quantitative analysis due to several problems such as chromatographic drifts and peak overlap. In this paper, we propose a Tchebichef moment method for the simultaneous quantitative analysis of three active compounds in Qingrejiedu oral liquid based on three-dimensional spectra in full scan mode of liquid chromatography with mass spectrometry. After the Tchebichef moments were calculated directly from the spectra, the quantitative linear models for three active compounds were established by stepwise regression. All the correlation coefficients were more than 0.9978. The limits of detection and limits of quantitation were less than 0.11 and 0.49 μg/mL, respectively. The intra- and interday precisions were less than 6.54 and 9.47%, while the recovery ranged from 102.56 to 112.15%. Owing to the advantages of multi-resolution and inherent invariance properties, Tchebichef moments could provide favorable results even in the situation of peaks shifting and overlapping, unknown interferences and noise signals, so it could be applied to the analysis of three-dimensional spectra in full scan mode of liquid chromatography with mass spectrometry.

  19. Analysis of daphnane orthoesters in poisonous Australian pimelea species by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Chow, Sharon; Fletcher, Mary T; McKenzie, Ross A

    2010-06-23

    Cattle grazing in arid rangelands of Australia suffer periodic extensive and serious poisoning by the plant species Pimelea trichostachya, P. simplex, and P. elongata. Pimelea poisoning (also known as St. George disease and Marree disease) has been attributed to the presence of the diterpenoid orthoester simplexin in these species. However, literature relating to previous studies is complicated by taxonomic revisions, and the presence of simplexin has not previously been verified in all currently recognized taxa capable of inducing pimelea poisoning syndrome, with no previous chemical studies of P. trichostachya (as currently classified) or P. simplex subsp. continua. We report here the isolation of simplexin from P. trichostachya and the development of a liquid chromatography-mass spectrometry/mass spectrometry (LC-MS/MS) method to measure simplexin concentrations in pimelea plant material. Simplexin was quantified by positive-ion atmospheric pressure chemical ionization (APCI) LC-MS/MS with selected reaction monitoring (SRM) of the m/z 533.3 > 253.3 transition. LC-MS/MS analysis of the four poisonous taxa P. trichostachya, P. elongata, P. simplex subsp. continua, and P. simplex subsp. simplex showed similar profiles with simplexin as the major diterpenoid ester component in all four taxa accompanied by varying amounts of related orthoesters. Similar analyses of P. decora, P. haematostachya, and P. microcephala also demonstrated the presence of simplexin in these species but at far lower concentrations, consistent with the limited reports of stock poisoning associated with these species. The less common, shrubby species P. penicillaris contained simplexin at up to 55 mg/kg dry weight and would be expected to cause poisoning if animals consumed sufficient plant material.

  20. Determination of chlorophylls and their derivatives in Gynostemma pentaphyllum Makino by liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Huang, S C; Hung, C F; Wu, W B; Chen, B H

    2008-09-10

    The objectives of this study were to develop a high performance liquid chromatography-mass spectrometry (HPLC-MS) method for determination of chlorophylls and their derivatives in Gynostemma pentaphyllum Makino, a traditional Chinese herb possessing vital biological activities. Chlorophylls were extracted with a quaternary solvent system of hexane-acetone-ethanol-toluene (10:7:6:7, v/v/v/v), followed by separation of a total of 15 chlorophylls and their derivatives within 32 min using a gradient mobile phase of acetone, acetonitrile and methanol and a HyPURITY C18 column, with detection at 660 nm and flow rate at 1 mL/min. Identification was carried out on the basis of retention behavior, absorption spectra and mass spectra using atmospheric pressure chemical ionization (APCI) in positive ion mode for detection. Of the 15 analytes, chlorophyll a, chlorophyll b, pheophytin a and pheophytin b were quantified by using standard calibration curves, with the other 11 being quantified with an internal standard Fast Green FCF. Chlorophyll extracts in G. pentaphyllum were found to contain pheophytin a (2508.3 microg/g), pheophytin a' (111.2 microg/g), chlorophyll a (113.8 microg/g), chlorophyll a' (11.0 microg/g), hydroxypheophytin a (88.6 microg/g), hydroxypheophytin a' (66.5 microg/g), pyropheophytin a (76.0 microg/g), hydroxychlorophyll a (23.8 microg/g), pheophytin b (319.6 microg/g), pheophytin b' (13.2 microg/g), chlorophyll b (287.9 microg/g), chlorophyll b' (11.1 microg/g), hydroxychlorophyll b (15.0 microg/g), hydroxypheophytin b (11.2 microg/g) and hydroxypheophytin b' (8.5 microg/g).

  1. Determination of ascorbic acid and carotenoids in food commodities by liquid chromatography with mass spectrometry detection.

    Science.gov (United States)

    Frenich, A Garrido; Torres, M E Hernández; Vega, A Belmonte; Vidal, J L Martínez; Bolaños, P Plaza

    2005-09-21

    Two methods, one to determine ascorbic acid and one to determine lycopene and beta-carotene, in vegetables and fruits by liquid chromatography coupled with mass spectrometry (LC-MS) have been established. The chromatographic separation of the studied compounds and their MS parameters were optimized to improve selectivity and sensitivity. In both methods, separation was carried out with two coupled columns, first a C(18) and then a dC(18), using as mobile phase 70% methanol (0.005% acetic acid) and 30% acetic acid 0.05% for ascorbic acid determination and a mixture of methanol, tetrahydrofuran, and acetonitrile (60:30:10 v/v/v) for carotenoid analysis in isocratic mode. The molecular ion was selected for the quantification in selective ion monitoring (SIM) mode. Ascorbic acid was detected with electrospray ionization probe (ESI) in negative mode, while chemical ionization atmospheric pressure (APCI) in positive mode was used for the target carotenoids. The methodology for ascorbic acid analysis is based on an extraction with polytron using methanol and a mixture of methaphosphoric acid and acetic acid. Extraction of the carotenoids was carried out with tetrahydrofuran/methanol (1:1) (v/v). The proposed methods were applied, after their corresponding validations, to the analysis of four varieties of tomatoes, tomato in tin enriched and dried tomato, and to the analysis of mango and kiwi fruits, to compare the content in these compounds. Moreover, the influence of the process of freezing and the effect that the manipulation/preservation has in the content of ascorbic acid in tomato have also been studied.

  2. Development and evaluation of a liquid chromatography tandem mass spectrometry method for simultaneous determination of salivary melatonin, cortisol and testosterone

    DEFF Research Database (Denmark)

    Jensen, Marie Aarrebo; Hansen, Åse Marie; Abrahamsson, Peter

    2011-01-01

    saliva. We used liquid-liquid extraction (LLE) followed by liquid chromatography coupled to electrospray tandem mass spectrometry (LC-ESI-MS/MS) recorded in positive ion mode. Saliva samples were collected by spitting directly into tubes and 250 µL were used for analysis. The limits of detection were 4...

  3. Direct Measurement of Free Estradiol in Human Serum and Plasma by Equilibrium Dialysis-Liquid Chromatography-Tandem Mass Spectrometry.

    Science.gov (United States)

    Ray, Julie A; Kushnir, Mark M; Rockwood, Alan L; Meikle, A Wayne

    2016-01-01

    We describe a direct method of measurement of free estradiol using equilibrium dialysis followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Serum aliquots and internal standards are extracted by liquid-liquid extraction using methyl-tert-butyl ether (MTBE) followed by derivatization with dansyl chloride. An API 5500 mass spectrometer operated in positive electrospray mode is used for detection.

  4. Determination of pyrazinamide in human by high performance liquid chromatography.

    Directory of Open Access Journals (Sweden)

    Revankar S

    1994-01-01

    Full Text Available A facile and sensitive high performance liquid chromatographic (HPLC technique has been developed for the determination pyrazinamide (PZA in human plasma. Nicotinamide(NIA is used as internal standard(IS. Plasma is deproteinized with 0.7 M perchloric acid; clear supernatant is neutralized with 1M NaOH and injected onto HPLC. The separation of pyrazinamide and the internal standard is carried out on a Supelco LC-18 (DB column with a basic mobile phase. Pyrazinoic acid, the major metabolite, other anti-tuberculous drugs and endogenous components do not interfere with measurement of pyrazinamide. The limit of detection of pyrazinamide with this method is 0.2 mg/0.2 ml plasma (CV 8.2%.

  5. [Determination of amygdalin in hawthorn by high performance liquid chromatography].

    Science.gov (United States)

    Lü, Weifeng; Ding, Mingyu

    2005-09-01

    A suitable method for extraction of amygdalin from hawthorn has been established. At first, the lipophilic components were removed with petroleum ether by ultrasonic extraction. The amygdalin was then extracted by methanol in a Soxhlet's apparatus. For quantitation, a high performance liquid chromatographic method was developed by using a reversed-phase C18 column, mobile phase of methanol-water (15:85, v/v) and a detection wavelengh of 215 nm. It can be concluded that the content of amygdalin is higher in the seeds than that in the hawthorn powder without the seeds and the yield of amygdalin is higher in the hawthorn pieces than that in the hawthorn powder.

  6. Determination of diflubenzuron and chlorbenzuron in fruits by combining acetonitrile-based extraction with dispersive liquid-liquid microextraction followed by high-performance liquid chromatography.

    Science.gov (United States)

    Ruan, Chunqiang; Zhao, Xiang; Liu, Chenglan

    2015-09-01

    In this study, a simple and low-organic-solvent-consuming method combining an acetonitrile-partitioning extraction procedure followed by "quick, easy, cheap, effective, rugged and safe" cleanup with ionic-liquid-based dispersive liquid-liquid microextraction and high-performance liquid chromatography with diode array detection was developed for the determination of diflubenzuron and chlorbenzuron in grapes and pears. Ionic-liquid-based dispersive liquid-liquid microextraction was performed using the ionic liquid 1-hexyl-3-methylimidazolium hexafluorophosphate as the extractive solvent and acetonitrile extract as the dispersive solvent. The main factors influencing the efficiency of the dispersive liquid-liquid microextraction were evaluated, including the extractive solvent type and volume and the dispersive solvent volume. The validation parameters indicated the suitability of the method for routine analyses of benzoylurea insecticides in a large number of samples. The relative recoveries at three spiked levels ranged between 98.6 and 109.3% with relative standard deviations of less than 5.2%. The limit of detection was 0.005 mg/kg for the two insecticides. The proposed method was successfully used for the rapid determination of diflubenzuron and chlorbenzuron residues in real fruit samples.

  7. Monitoring of cefepime in human serum and plasma by micellar electrokinetic capillary chromatography: Improvement of sample preparation and validation by liquid chromatography coupled to mass spectrometry.

    Science.gov (United States)

    Šestáková, Nela; Theurillat, Regula; Sendi, Parham; Thormann, Wolfgang

    2017-02-20

    Cefepime monitoring in deproteinized human serum and plasma by micellar electrokinetic capillary chromatography and liquid chromatography coupled to mass spectrometry in presence of other drugs is reported. For micellar electrokinetic capillary chromatography, sample preparation comprised dodecylsulfate protein precipitation at pH 4.5 using an increased buffer concentration compared to that of a previous assay and removal of hydrophobic compounds with dichloromethane. This provided robust conditions for cefepime analysis in the presence of sulfamethoxazole and thus enabled its determination in samples of patients that receive co-trimoxazole. The liquid chromatography assay is based upon use of a column with a pentafluorophenyl-propyl modified and multi-endcapped stationary phase and the coupling to electrospray ionization with a single quadrupole detector. The performances of both assays with multi-level internal calibration were assessed with calibration and control samples and both assays were determined to be robust. Cefepime levels monitored by micellar electrokinetic capillary chromatography in samples from patients that were treated with cefepime only and with cefepime and co-trimoxazole were found to compare well with those obtained by liquid chromatography coupled to mass spectrometry. Cefepime drug levels determined by micellar electrokinetic capillary chromatography could thereby be validated. This article is protected by copyright. All rights reserved.

  8. Determination of chloroacetanilide herbicide metabolites in water using high-performance liquid chromatography-diode array detection and high-performance liquid chromatography/mass spectrometry

    Science.gov (United States)

    Hostetler, K.A.; Thurman, E.M.

    2000-01-01

    Analytical methods using high-performance liquid chromatography-diode array detection (HPLC-DAD) and high-performance liquid chromatography/mass spectrometry (HPLC/MS) were developed for the analysis of the following chloroacetanilide herbicide metabolites in water: alachlor ethanesulfonic acid (ESA); alachlor oxanilic acid; acetochlor ESA; acetochlor oxanilic acid; metolachlor ESA; and metolachlor oxanilic acid. Good precision and accuracy were demonstrated for both the HPLC-DAD and HPLC/MS methods in reagent water, surface water, and ground water. The average HPLC-DAD recoveries of the chloroacetanilide herbicide metabolites from water samples spiked at 0.25, 0.5 and 2.0 ??g/l ranged from 84 to 112%, with relative standard deviations of 18% or less. The average HPLC/MS recoveries of the metabolites from water samples spiked at 0.05, 0.2 and 2.0 ??g/l ranged from 81 to 118%, with relative standard deviations of 20% or less. The limit of quantitation (LOQ) for all metabolites using the HPLC-DAD method was 0.20 ??g/l, whereas the LOQ using the HPLC/MS method was at 0.05 ??g/l. These metabolite-determination methods are valuable for acquiring information about water quality and the fate and transport of the parent chloroacetanilide herbicides in water. Copyright (C) 2000 Elsevier Science B.V.

  9. Chemical fingerprint of Ganmaoling granule by double-wavelength ultra high performance liquid chromatography and ultra high performance liquid chromatography with quadrupole time-of-flight mass spectrometry.

    Science.gov (United States)

    Lou, Qiong; Ye, Xiaolan; Zhou, Yingyi; Li, Hua; Song, Fenyun

    2015-06-01

    A method incorporating double-wavelength ultra high performance liquid chromatography with quadrupole time-of-flight mass spectrometry was developed for the investigation of the chemical fingerprint of Ganmaoling granule. The chromatographic separations were performed on an ACQUITY UPLC HSS C18 column (2.1 × 50 mm, 1.8 μm) at 30°C using gradient elution with water/formic acid (1%) and acetonitrile at a flow rate of 0.4 mL/min. A total of 11 chemical constituents of Ganmaoling granule were identified from their molecular weight, UV spectra, tandem mass spectrometry data, and retention behavior by comparing the results with those of the reference standards or literature. And 25 peaks were selected as the common peaks for fingerprint analysis to evaluate the similarities among 25 batches of Ganmaoling granule. The results of principal component analysis and orthogonal projection to latent structures discriminant analysis showed that the important chemical markers that could distinguish the different batches were revealed as 4,5-di-O-caffeoylquinic acid, 3,5-di-O-caffeoylquinic acid, and 4-O-caffeoylquinic acid. This is the first report of the ultra high performance liquid chromatography chemical fingerprint and component identification of Ganmaoling granule, which could lay a foundation for further studies of Ganmaoling granule.

  10. Analyses of Indole Compounds in Sugar Cane (Saccharum officinarum L. Juice by High Performance Liquid Chromatography and Liquid Chromatography-Mass Spectrometry after Solid-Phase Extraction

    Directory of Open Access Journals (Sweden)

    Jean Wan Hong Yong

    2017-03-01

    Full Text Available Simultaneous quantitative analysis of 10 indole compounds, including indole-3-acetic acid (IAA, one of the most important naturally occurring auxins and some of its metabolites, by high performance liquid chromatography (HPLC and liquid chromatography-mass spectrometry (LC-MS after solid-phase extraction (SPE was reported for the first time. The analysis was carried out using a reverse phase HPLC gradient elution, with an aqueous mobile phase (containing 0.1% formic acid modified by methanol. Furthermore, a novel SPE procedure was developed for the pre-concentration and purification of indole compounds using C18 SPE cartridges. The combination of SPE, HPLC, and LC-MS was applied to screen for the indole compounds present in sugar cane (Saccharum officinarum L. juice, a refreshing beverage with various health benefits. Finally, four indole compounds were successfully detected and quantified in sugar cane juice by HPLC, which were further unequivocally confirmed by LC-MS/MS experiments operating in the multiple reaction monitoring (MRM mode.

  11. Comparison of liquid-liquid extraction-thin layer chromatography with solid-phase extraction-high-performance thin layer chromatography in detection of urinary morphine.

    Science.gov (United States)

    Ahadi, Ali; Partoazar, Alireza; Abedi-Khorasgani, Mohammad-Hassan; Shetab-Boushehri, Seyed Vahid

    2011-09-01

    Liquid-liquid extraction-thin layer chromatography (LLE-TLC) has been a common and routine combined method for detection of drugs in biological materials. Solid-phase extraction (SPE) is gradually replacing the traditional LLE method. High performance thin layer chromatography (HPTLC) has several advantages over TLC. The present work studied the higher efficiency of a new SPE-HPTLC method over that of a routine LLE-TLC method, in extraction and detection of urinary morphine. Fifty-eight urine samples, primarily identified as morphine-positive samples by a strip test, were re-screened by LLE-TLC and SPE-HPTLC. The results of LLE-TLC and SPE-HPTLC were then compared with each other. The results showed that the SPE-HPTLC detected 74% of total samples as morphine-positive samples whereas the LLE-TLC detected 48% of the same samples. We further discussed the effect of codeine abuse on TLC analysis of urinary morphine. Regarding the importance of morphine detection in urine, the present combined SPE-HPTLC method is suggested as a replacement method for detection of urinary morphine by many reference laboratories.

  12. Evaluation of the Kinetic Performance Differences between Hydrophilic-Interaction Liquid Chromatography and Reversed-Phase Liquid Chromatography under Conditions of Identical Packing Structure.

    Science.gov (United States)

    Song, Huiying; Desmet, Gert; Cabooter, Deirdre

    2015-12-15

    A protocol using trifluoroacetic acid at a temperature of 60 °C is developed for the adequate removal of the stationary phase of reversed-phase liquid chromatography (RPLC) columns. This procedure allows for studying the same column first under RPLC and subsequently under hydrophilic-interaction liquid chromatography (HILIC) conditions to isolate intrinsic differences between mass transfer properties in HILIC and RPLC from differences in packing quality. The established procedure allows for a complete removal of the stationary phase (confirmed by retention studies and thermogravimetry analyses) while leaving the structure of the packing unaffected (witnessed by an unchanged external porosity and pressure drop). Accurate plate height analysis comparing compounds at the same zone retention factor indicates a significant difference in reduced c-term (typically 40-80% larger under HILIC conditions), despite the columns otherwise being identical. Correcting for the known contributions of longitudinal diffusion (b-term) and mass transfer (cm- and cs-term) to focus on band broadening originating from eddy dispersion, similar strong differences are observed (differences of some h = 0.3 up to 1.2). These findings show that the interior structure and retention mechanism of the particles have a very strong effect on the observed eddy dispersion, a factor typically ascribed to phenomena occurring outside the particles. This also implies that comparing the quality of packings of different particle types is virtually impossible without the availability of a sound model to correct for the intraparticle effect on the observed eddy dispersion.

  13. Dosage direct des alcools et éthers dans les carburants par chromatographie en phase liquide Direct Measurement of Alcohols and Ethers in Gasohols by Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    Petroff N.

    2006-11-01

    Full Text Available Les différents composés oxygénés potentiels des carburants (alcools jusqu'aux butanols, acétone et éthers en C5 et C6 sont dosés par chromatographie en phase liquide inversée, avec deux qualités d'éluant sur la même colonne (RP 18. L'analyse est faite à 50 °C, avec un détecteur réfractométrique. La limite de sensibilité peut atteindre 100 ppm pour les alcools. The different potential oxygenated compounds in gasolines blended with alcohols up to butanols, acetone and ethers with 5 and 6 carbons are measured by reverse-phase liquid chromatography with two elution systems in the same column (RP 18. Analysis is performed at 50°C with a refractometer as detector. The sensitivity limit can reach 100 ppm for alcohols.

  14. Liquid chromatography-mass spectrometric and liquid chromatography-tandem mass spectrometric determination of hallucinogenic indoles psilocin and psilocybin in "magic mushroom" samples.

    Science.gov (United States)

    Kamata, Tooru; Nishikawa, Mayumi; Katagi, Munehiro; Tsuchihashi, Hitoshi

    2005-03-01

    Accurate and sensitive analytical methods for psilocin (PC) and psilocybin (PB), tryptamine-type hallucinogens contained in "magic mushrooms," were investigated using liquid chromatography-mass spectrometry (LC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS-MS). The chromatographic separation on an ODS column and mass spectral information gave complete discrimination between PC and PB without derivatization. The mass spectrometric detection had a high sensitivity, and the tandem mass spectrometric detection provided more specificity and accuracy, as well as high sensitivity. The detection limits ranged from 1 to 25 pg by LC-MS in the selected ion monitoring mode, and the intra- and inter-day coefficients of variation were estimated to be 4.21-5.93% by LC-MS-MS in the selected reaction monitoring mode. By applying the present LC-MS-MS technique to four real samples, the contents of PC and PB were found to vary over a wide range (0.60-1.4 and 0.18-3.8 mg/g dry wt. for PC and PB, respectively) between samples.

  15. On-line comprehensive two-dimensional normal-phase liquid chromatography × reversed-phase liquid chromatography for preparative isolation of Peucedanum praeruptorum.

    Science.gov (United States)

    Wang, Xin-Yuan; Li, Jia-Fu; Jian, Ya-Mei; Wu, Zhen; Fang, Mei-Juan; Qiu, Ying-Kun

    2015-03-27

    A new on-line comprehensive preparative two-dimensional normal-phase liquid chromatography × reversed-phase liquid chromatography (2D NPLC × RPLC) system was developed for the separation of complicated natural products. It was based on the use of a silica gel packed medium-pressure column as the first dimension and an ODS preparative HPLC column as the second dimension. The two dimensions were connected with normal-phase (NP) and reversed-phase (RP) enrichment units, involving a newly developed airflow assisted adsorption (AAA) technique. The instrument operation and the performance of this NPLC × RPLC separation method were illustrated by gram-scale isolation of ethanol extract from the roots of Peucedanum praeruptorum. In total, 19 compounds with high purity were obtained via automated multi-step preparative separation in a short period of time using this system, and their structures were comprehensively characterized by ESI-MS, (1)H NMR, and (13)C NMR. Including two new compounds, five isomers in two groups with identical HPLC and TLC retention values were also obtained and identified by 1D NMR and 2D NMR. This is the first report of an NPLC × RPLC system successfully applied in an on-line preparative process. This system not only solved the interfacing problem of mobile-phase immiscibility caused by NP and RP separation, it also exhibited apparent advantages in separation efficiency and sample treatment capacity compared with conventional methods.

  16. Determination of Niacinamide in Lotions and Creams Using Liquid-Liquid Extraction and High-Performance Liquid Chromatography

    Science.gov (United States)

    Usher, Karyn M.; Simmons, Carolyn R.; Keating, Daniel W.; Rossi, Henry F., III

    2015-01-01

    Chemical separations are an important part of an undergraduate chemistry curriculum. Sophomore students often get experience with liquid-liquid extraction in organic chemistry classes, but liquid-liquid extraction is not as often introduced as a quantitative sample preparation method in honors general chemistry or quantitative analysis classes.…

  17. Determination of Niacinamide in Lotions and Creams Using Liquid-Liquid Extraction and High-Performance Liquid Chromatography

    Science.gov (United States)

    Usher, Karyn M.; Simmons, Carolyn R.; Keating, Daniel W.; Rossi, Henry F., III

    2015-01-01

    Chemical separations are an important part of an undergraduate chemistry curriculum. Sophomore students often get experience with liquid-liquid extraction in organic chemistry classes, but liquid-liquid extraction is not as often introduced as a quantitative sample preparation method in honors general chemistry or quantitative analysis classes.…

  18. Purification of capsular polysaccharide from Neisseria meningitidis serogroup C by liquid chromatography.

    Science.gov (United States)

    Pato, Tânia Pinheiro; Barbosa, Antonio de Pádua R; da Silva Junior, José Godinho

    2006-03-07

    Neisseria meningitidis serogroup C capsular polysaccharide (MenCPS) is an important antigen against meningococcal infection. This paper describes a new purification methodology employing liquid chromatography that resulted in a polysaccharide showing the characteristics recommended by the World Health Organization for vaccine purposes. In this method, steps of the traditional procedure that yield low recovery and use toxic materials were modified. The present process consists in the following steps: (1) continuous flow centrifugation of the culture for removal of the cells; (2) supernatant concentration by tangential filtration (100 kDa cutoff); (3) addition of 0.5% DOC, heating to 55 degrees C during 30 min and tangential filtration (100 kDa cutoff); (4) anion exchange chromatography (Source 15Q) and (5) size exclusion chromatography (Sepharose CL-4B). The polysaccharide C fraction obtained in that way was dialyzed and freeze-dried. The structural identity of the polysaccharide was demonstrated by (1)H-NMR spectrometry.

  19. Analysis of acrylamide in cooked foods by liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Rosén, Johan; Hellenäs, Karl-Erik

    2002-07-01

    A method using liquid chromatography tandem mass spectrometry (LC-MS-MS) with electrospray for the analysis of acrylamide in foods is reported. The method comprises the addition of deuterium-labelled acrylamide-d3, extraction with water, mixed mode solid phase extraction, ultrafiltration and a graphitised carbon column for chromatography. The transitions m/z 72 > 55, 72 > 54, 72 > 44, 72 > 27, 72 > 72 and 75 > 58 were recorded in multiple reaction monitoring mode for identification and quantification. In-house validation data for products from potatoes and cereals (30 to 10,000 microg kg(-1)) are presented (accuracy 91 to 102%, relative standard deviation 3 to 21%). Interlaboratory validation data (comparison with gas chromatography mass spectrometry, 25 to 2000 microg kg(-1)) showed excellent results (r2 = 0.998).

  20. High-throughput determination of cortisol, cortisone, and melatonin in oral fluid by on-line turbulent flow liquid chromatography interfaced with liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Fustinoni, Silvia; Polledri, Elisa; Mercadante, Rosa

    2013-07-15

    Cortisol, cortisone, and melatonin (CORTol, CORTone, and MELA, respectively) are hormones related to stress and sleep disorders. Their detection is relevant to epidemiological studies aimed at investigating the effects of circadian cycle disruption. The aim of this study was to develop and evaluate a high-throughput assay for the detection of CORTol, CORTone, and MELA concentrations in non-invasively collected oral fluid samples. A liquid chromatography/tandem mass spectrometry (LC/MS/MS) method to measure levels of CORTol, CORTone, and MELA in oral fluid samples in the presence of deuterated analogs was optimized and validated. A 50 μL aliquot of oral fluid sample, obtained by centrifugation of a chewed swab, was purified using on-line turbulent flow liquid chromatography. Analytes were then separated using C18 reversed-phase chromatography, subjected to positive ionization using an electrospray source, then quantitated using a triple quadrupole mass detector in the selected reaction monitoring mode. Limits of quantification and linear dynamic ranges were found to be 0.55 nmol/L, 5.5 nmol/L, and 0.004 nmol/L, and up to 28 nmol/L, 277 nmol/L, and 0.43 nmol/L for CORTol, CORTone, and MELA, respectively. Inter- and intra-run precisions as relative standard deviation values were <5%, and accuracies were within 95-106% of theoretical concentrations. An evaluation of matrix effects showed that the use of deuterated analogs controlled sources of bias. Furthermore, the total analysis time per sample was 13 min, resulting in a throughput of approximately 100 samples/day. To our knowledge, this is the first automated, high-throughput assay for the simultaneous quantification of CORTol, CORTone, and MELA in oral fluid specimens. Copyright © 2013 John Wiley & Sons, Ltd.

  1. Online coupling of hydrophilic interaction/strong cation exchange/reversed-phase liquid chromatography with porous graphitic carbon liquid chromatography for simultaneous proteomics and N-glycomics analysis.

    Science.gov (United States)

    Zhao, Yun; Law, Henry C H; Zhang, Zaijun; Lam, Herman C; Quan, Quan; Li, Guohui; Chu, Ivan K

    2015-10-09

    In this study we developed a fully automated three-dimensional (3D) liquid chromatography methodology-comprising hydrophilic interaction separation as the first dimension, strong cation exchange fractionation as the second dimension, and low-pH reversed-phase (RP) separation as the third dimension-in conjunction downstream with additional complementary porous graphitic carbon separation, to capture non-retained hydrophilic analytes, for both shotgun proteomics and N-glycomics analyses. The performance of the 3D system alone was benchmarked through the analysis of the total lysate of Saccharomyces cerevisiae, leading to improved hydrophilic peptide coverage, from which we identified 19% and 24% more proteins and peptides, respectively, relative to those identified from a two-dimensional hydrophilic interaction liquid chromatography and low-pH RP chromatography (HILIC-RP) system over the same mass spectrometric acquisition time; consequently, the 3D platform also provided enhanced proteome and protein coverage. When we applied the integrated technology to analyses of the total lysate of primary cerebellar granule neurons, we characterized a total of 2201 proteins and 16,937 unique peptides for this primary cell line, providing one of its most comprehensive datasets. Our new integrated technology also exhibited excellent performance in the first N-glycomics analysis of cynomolgus monkey plasma; we successfully identified 122 proposed N-glycans and 135 N-glycosylation sites from 122 N-glycoproteins, and confirmed the presence of 38 N-glycolylneuraminic acid-containing N-glycans, a rare occurrence in human plasma, through tandem mass spectrometry for the first time.

  2. Determination of acaricides in honey by high-performance liquid chromatography with photodiode array detection.

    Science.gov (United States)

    Martel, Anne-Claire; Zeggane, Sarah

    2002-04-19

    Rapid analytical methods are described to control quality of honeys, concerning residues of acaricides applied in hives to prevent Varroa jacobsoni infestation. A liquid-liquid extraction with hexane-propanol-2-ammonia (60 ml:30 ml:0.28%) was used for the simultaneous analysis of coumaphos, bromopropylate, amitraz and fluvalinate. For thymol, one clean up on a solid-phase extraction C18 (500 mg, 6 ml) column was performed; for rotenone, a liquid extraction with dichloromethane was realised. Quantitative recoveries obtained with honey were satisfactory and were superior to 80%. All acaricides are identified by reversed-phase high-performance liquid chromatography with photodiode array detection. Quantification limits obtained were below maximal residue limits when these exist.

  3. Gas chromatography on wall-coated open-tubular columns with ionic liquid stationary phases.

    Science.gov (United States)

    Poole, Colin F; Lenca, Nicole

    2014-08-29

    Ionic liquids have moved from novel to practical stationary phases for gas chromatography with an increasing portfolio of applications. Ionic liquids complement conventional stationary phases because of a combination of thermophysical and solvation properties that only exist for ionic solvents. Their high thermal stability and low vapor pressure makes them suitable as polar stationary phases for separations requiring high temperatures. Ionic liquids are good solvents and can be used to expand the chemical space for separations. They are the only stationary phases with significant hydrogen-bond acidity in common use; they extend the hydrogen-bond basicity of conventional stationary phases; they are as dipolar/polarizable as the most polar conventional stationary phases; and some ionic liquids are significantly less cohesive than conventional polar stationary phases. Problems in column coating techniques and related low column performance, column activity, and stationary phase reactivity require further exploration as the reasons for these features are poorly understood at present.

  4. Determination of Finasteride in Tablets by High Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    K. Basavaiah

    2007-01-01

    Full Text Available A rapid, highly sensitive high performance liquid chromatographic method has been developed for the determination of finasteride(FNS in bulk drug and in tablets. FNS was eluted from a ODS C18 reversed phase column at laboratory temperature (30 ± 2°C with a mobile phase consisting of methanol and water (80+20 at a flow rate of 1 mL min-1 with UV detection at 225 nm. The retention time was ∼ 6.1 min and each analysis took not more than 10 min. Quantitation was achieved by measurement of peak area without using any internal standard. Calibration graph was linear from 2.0 to 30 μg mL-1 with limits of detection (LOD and quantification (LOQ being 0.2 and 0.6 μg mL-1, respectively. The method was validated according to the current ICH guidelines. Within-day co efficients of variation (CV ranged from 0.31 to 0.69% and between-day CV were in the range 1.2-3.2%. Recovery of FNS from the pharmaceutical dosage forms ranged from 97.89 – 102.9 with CV of 1.41-4.13%. The developed method was compared with the official method for FNS determination in its tablet forms.

  5. Determination of acrylamide in coffee and chocolate by pressurised fluid extraction and liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Pardo, O; Yusà, V; Coscollà, C; León, N; Pastor, A

    2007-07-01

    A selective and sensitive procedure has been developed and validated for the determination of acrylamide in difficult matrices, such as coffee and chocolate. The proposed method includes pressurised fluid extraction (PFE) with acetonitrile, florisil clean-up purification inside the PFE extraction cell and detection by liquid chromatography (LC) coupled to atmospheric pressure ionisation in positive mode tandem mass spectrometry (APCI-MS-MS). Comparison of ionisation sources (atmospheric pressure chemical ionisation (APCI), atmospheric pressure photoionization (APPI) and the combined APCI/APPI) and clean-up procedures were carried out to improve the analytical signal. The main parameters affecting the performance of the different ionisation sources were previously optimised using statistical design of experiments (DOE). PFE parameters were also optimised by DOE. For quantitation, an isotope dilution approach was used. The limit of quantification (LOQ) of the method was 1 microg kg(-1) for coffee and 0.6 microg kg(-1) for chocolate. Recoveries ranged between 81-105% in coffee and 87-102% in chocolate. The accuracy was evaluated using a coffee reference test material FAPAS T3008. Using the optimised method, 20 coffee and 15 chocolate samples collected from Valencian (Spain) supermarkets, were investigated for acrylamide, yielding median levels of 146 microg kg(-1) in coffee and 102 microg kg(-1) in chocolate.

  6. Analyses of acute kidney injury biomarkers by ultra-high performance liquid chromatography with mass spectrometry.

    Science.gov (United States)

    Al Za'abi, Mohammed; Ali, Badreldin H; ALOthman, Zeid A; Ali, Imran

    2016-01-01

    The newly developed acute kidney injury biomarkers are very important for the early and timely detection of kidney diseases. This review contains details of the analyses of several acute kidney injury biomarkers using ultra-high performance liquid chromatography-mass spectrometry in urine and plasma samples. In this review we attempt to discuss some aspects of the types of the biomarkers, patents, sample preparation, and the analyses. Besides, efforts were also made to discuss the possible uses of superficially porous (core-shell) columns in traditional and inexpensive high-performance liquid chromatography instruments. Additionally, the challenges and the future prospects are also highlighted. The present review will be useful for the academicians, scientists, and clinicians for the early detection of acute kidney injury biomarkers.

  7. Homochiral metal-organic framework used as a stationary phase for high-performance liquid chromatography.

    Science.gov (United States)

    Kong, Jiao; Zhang, Mei; Duan, Ai-Hong; Zhang, Jun-Hui; Yang, Rui; Yuan, Li-Ming

    2015-02-01

    Metal-organic frameworks are promising porous materials. Chiral metal-organic frameworks have attracted considerable attention in controlling enantioselectivity. In this study, a homochiral metal-organic framework [Co(2) (D-cam)(2) (TMDPy)] (D-cam = D-camphorates, TMDPy = 4,4'-trimethylenedipyridine) with a non-interpenetrating primitive cubic net has been used as a chiral stationary phase in high-performance liquid chromatography. It has allowed the successful separation of six positional isomers and six chiral compounds. The good selectivity and baseline separation, or at least 60% valley separation, confirmed its excellent molecular recognition characteristics. The relative standard deviations for the retention time of run-to-run and column-to-column were less than 1.8 and 3.1%, respectively. These results demonstrate that [Co(2) (D-cam)(2) (TMDPy)] may represent a promising chiral stationary phase for use in high-performance liquid chromatography.

  8. Analysis of antimycin A by reversed-phase liquid chromatography/nuclear magnetic-resonance spectrometry

    Science.gov (United States)

    Ha, Steven T.K.; Wilkins, Charles L.; Abidi, Sharon L.

    1989-01-01

    A mixture of closely related streptomyces fermentation products, antimycin A, Is separated, and the components are identified by using reversed-phase high-performance liquid chromatography with directly linked 400-MHz proton nuclear magnetic resonance detection. Analyses of mixtures of three amino acids, alanine, glycine, and valine, are used to determine optimal measurement conditions. Sensitivity increases of as much as a factor of 3 are achieved, at the expense of some loss in chromatographic resolution, by use of an 80-μL NMR cell, Instead of a smaller 14-μL cell. Analysis of the antimycin A mixture, using the optimal analytical high performance liquid chromatography/nuclear magnetic resonance conditions, reveals it to consist of at least 10 closely related components.

  9. Fractionation of Gibberellins in plant extracts by reverse phase high performance liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Jones, M.G.; Metzger, J.D.; Zeevaart, J.A.D.

    1980-02-01

    In studies on endogenous plant gibberellins (GAs), reverse phase (Bondapak C/sub 18/) high performance liquid chromatography (HPLC) has proved to be a useful method for the fractionation of plant extracts. The behavior of 18 authentic GAs in such a chromatographic system is described. The main factors determining chromatographic behavior are the degree and the position of hydroxylation of the GA. As an illustration of the use of reverse phase HPLC, the endogeneous GAs of immature seeds of Pharbitis nil L., strain Violet, were reinvestigated. The presence of gibberellins A/sub 3/, A/sub 5/, A/sub 17/, A/sub 20/, and A/sub 29/ was confirmed by gas-liquid chromatography-mass spectrometry. In addition, two other GAs, A/sub 19/ and A/sub 44/, were also identified in extracts of this material.

  10. Application of micellar liquid chromatography for the determination of antitumoral and antiretroviral drugs in plasma.

    Science.gov (United States)

    Peris-Vicente, Juan; Casas-Breva, Inmaculada; Roca-Genovés, Pasqual; Esteve-Romero, Josep

    2014-01-01

    In micellar liquid chromatography, the mobile phase is made of a surfactant and, eventually, an alcohol. This article describes several methods to measure the concentration of antitumoral and antiretroviral drugs in plasma, utilizing micellar liquid chromatography. Samples can be injected after dilution with a micellar solution and filtration, because proteins and other endogenous compounds are solubilized in micellar medium. We will discuss the following optimized parameters: dilution ratio, type of column, detection conditions and mobile phase composition. This article will also cover the validation performed following the International Conference on Harmonization guidelines and the results reported in the literature, indicating that the methods are useful for the routine analysis of plasma samples for clinical purposes.

  11. Identification of bupropion urinary metabolites by liquid chromatography/mass spectrometry.

    Science.gov (United States)

    Petsalo, Aleksanteri; Turpeinen, Miia; Tolonen, Ari

    2007-01-01

    Human urinary metabolism of the antidepressant bupropion was studied using liquid chromatography/time-of-flight mass spectrometry (LC/TOFMS) and liquid chromatography/tandem mass spectrometry (LC/MS/MS). A total of 20 metabolites were detected and identified. The phase I metabolism included formation of morpholinohydroxybupropion, threo- and erythrohydrobupropion, aromatic hydroxylation, butyl group hydroxylation with ketone hydrogenation and dihydroxylation. These metabolites were detected either as the free form or as glucuronide and/or sulphate conjugates. In addition also m-chlorohippuric acid was detected. Of the phase I metabolites, a dihydroxylation to the aromatic ring and to the methyl group in the middle of the substrate molecule was reported here for the first time, as well as eight of the glucuronide conjugates (to hydroxy, dihydroxy, hydroxy and hydrogenation metabolites) and three of the sulphate conjugates (to aromatic hydroxy and hydroxy and hydrogenation metabolites). Copyright (c) 2007 John Wiley & Sons, Ltd.

  12. Use, history, and liquid chromatography/mass spectrometry chemical analysis of Aconitum

    Directory of Open Access Journals (Sweden)

    Mohamed El-Shazly

    2016-01-01

    Full Text Available Aconitum and its products have been used in Asia for centuries to treat various ailments, including arthritis, gout, cancer, and inflammation. In general, their preparations and dispensing have been restricted to qualified folk medicine healers due to their low safety index and reported toxicity. In the past few decades, official guidelines have been introduced in Asian pharmacopeias to control Aconitum herbal products. However, these guidelines were based on primitive analytical techniques for the determination of the whole Aconitum alkaloids and were unable to distinguish between toxic and nontoxic components. Recent advances in analytical techniques, especially high performance liquid chromatography (HPLC and electrophoresis coupled with highly sensitive detectors, allowed rapid and accurate determination of Aconitum secondary metabolites. Reports focusing on liquid chromatography/mass spectrometry analysis of Aconitum and its herbal products are discussed in the current review. This review can be used by the health regulatory authorities for updating pharmacopeial guidelines of Aconitum and its herbal products.

  13. Arsenic speciation by liquid chromatography coupled with ionspray tandem mass spectrometry

    DEFF Research Database (Denmark)

    Corr, J. J.; Larsen, Erik Huusfeldt

    1996-01-01

    fragmentation patterns showing molecular dissociation through an expected common product ion were obtained for the four arsenosugars, Molecular mode detection was utilized for qualitative verification of speciation analysis by high-performance liquid chromatography coupled to inductively coupled plasma mass......Ionspray mass spectrometry, a well established organic analysis technique, has been coupled to high-performance liquid chromatography for speciation of organic arsenic compounds, The ionspray source and differentially pumped interface of the mass spectrometer were operated in dual modes...... for elemental and molecular analysis, Tandem mass spectrometry was employed to increase selectivity, Dual mode detection was applied to demonstrate the utility of the technique for analysis of nine organoarsenic standards, including four dimethylarsinylriboside derivatives (arsenosugars), Structural...

  14. Current practice of liquid chromatography-mass spectrometry in metabolomics and metabonomics.

    Science.gov (United States)

    Gika, Helen G; Theodoridis, Georgios A; Plumb, Robert S; Wilson, Ian D

    2014-01-01

    Based on publication and citation numbers liquid chromatography (LC-MS) has become the major analytical technology in the field of global metabolite profiling. This dominance reflects significant investments from both the research community and instrument manufacturers. Here an overview of the approaches taken for LC-MS-based metabolomics research is given, describing critical steps in the realisation of such studies: study design and its needs, specific technological problems to be addressed and major obstacles in data treatment and biomarker identification. The current state of the art for LC-MS-based analysis in metabonomics/metabolomics is described including recent developments in liquid chromatography, mass spectrometry and data treatment as these are applied in metabolomics underlining the challenges, limitations and prospects for metabolomics research. Examples of the application of metabolite profiling in the life sciences focusing on disease biomarker discovery are highlighted. In addition, new developments and future prospects are described. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Liquid chromatography-thermospray mass spectrometry of DNA adducts formed with mitomycin C, porfiromycin and thiotepa.

    Science.gov (United States)

    Musser, S M; Pan, S S; Callery, P S

    1989-07-14

    High-performance liquid chromatography (HPLC) and thermospray mass spectrometry were combined for the analysis of DNA adducts formed from the interaction of the anticancer drugs mitomycin C, porfiromycin and thiotepa with calf thymus DNA. The adducts formed from reaction of mitomycin C and porfiromycin with DNA were separated from unmodified nucleosides by HPLC on a C18 column and identified by thermospray mass spectrometry. Thiotepa DNA adducts readily depurinated from DNA and were chromatographed and identified by thermospray liquid chromatography-mass spectrometry as the modified bases without the ribose moiety attached. The utility of thermospray mass spectrometry for the identification of microgram quantities of nucleoside adducts and depurinated base adducts of these anticancer drugs was demonstrated.

  16. 现代液相色谱进展%Progress of Modern Liquid Chromatography

    Institute of Scientific and Technical Information of China (English)

    韩南银; 王利生; 傅若农

    1999-01-01

      本文在查阅大量文献的基础上从液相色谱的发展史、固定相、流动相以及检测器四个方面综述了液相色谱的进展,对了解液相色谱的新进展有着重要参考价值。%  The paper dealed with the progress of developing history, stationary phases, fluid phases and detectors of liquid chromatography. It has important reference values for chemists to learn the new progress of modern liquid chromatography in the field of chemistry.

  17. Serum Protein Profile Study of Clinical Samples Using High Performance Liquid Chromatography-Laser Induced Fluorescence

    DEFF Research Database (Denmark)

    Karemore, Gopal Raghunath; Ukendt, Sujatha; Rai, Lavanya

    2009-01-01

    The serum protein profiles of normal subjects, patients diagnosed with cervical cancer, and oral cancer were recorded using High Performance Liquid Chromatography combined with Laser Induced Fluorescence detection (HPLC-LIF). Serum protein profiles of the above three classes were tested for estab......The serum protein profiles of normal subjects, patients diagnosed with cervical cancer, and oral cancer were recorded using High Performance Liquid Chromatography combined with Laser Induced Fluorescence detection (HPLC-LIF). Serum protein profiles of the above three classes were tested...... for establishing the ability of HPLC-LIF protein profiling technique for discrimination, using hard clustering and Fuzzy clustering methods. The clustering algorithms have quite successfully classified the profiles as belonging to normal, cancer of cervix, and oral cancer conditions....

  18. High-pressure liquid chromatography with direct injection of gas sample.

    Science.gov (United States)

    Astanin, Anton I; Baram, Grigory I

    2017-06-09

    The conventional method of using liquid chromatography to determine the composition of a gaseous mixture entails dissolving vapors in a suitable solvent, then obtaining a chromatograph of the resulting solution. We studied the direct introduction of a gaseous sample into a C18 reversed-phase column, followed by separation of the components by HPLC with UV detection. Since the chromatography was performed at high pressure, vapors readily dissolved in the eluent and the substances separated in the column as effectively as in liquid samples. Samples were injected into the column in two ways: a) through the valve without a flow stop; b) after stopping the flow and relieving all pressure. We showed that an injectable gas volume could reach 70% of column dead volume. When an injected gaseous sample volume was less than 10% of the column dead volume, the resulting peaks were symmetrical and the column efficiency was high. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Alternative solvents for improving the greenness of normal phase liquid chromatography of lipid classes.

    Science.gov (United States)

    Prache, Nolwenn; Abreu, Sonia; Sassiat, Patrick; Thiébaut, Didier; Chaminade, Pierre

    2016-09-16

    An evaluation of solvents alternative to n-heptane (d-limonene and hexamethyldisiloxane) and chloroform (cyclopentyl methyl ether, 2-methyltetrahydrofuran and isopentyl acetate) was developed for lipid classes separation of non-polar cholesteryl ester to highly polar phospholipids by high-performance liquid chromatography on bare silica stationary phase and evaporative light-scattering detection. Screening of alternative solvents was used to estimate their compatibility with liquid chromatography and evaporative light-scattering detection and to evaluate their chromatographic selectivity. This work shows that n-heptane can be advantageously replaced by hexamethyldisiloxane. An increase of non-polar lipids retention is observed with hexamethyldisiloxane as weak solvent. Chloroform, which is largely used for lipid analysis, might be replaced efficaciously by cyclopentyl methyl ether, 2-methyltetrahydrofuran or isopentyl acetate. Aside from offering a different selectivity, the gradients composed by one or both alternative solvents gave efficient and comparable or even better separations than those obtained with conventional solvents.

  20. Ultrasound-assisted dispersive liquid-liquid microextraction combined with high-performance liquid chromatography-fluorescence detection for sensitive determination of biogenic amines in rice wine samples.

    Science.gov (United States)

    Huang, Ke-Jing; Wei, Cai-Yun; Liu, Wei-Li; Xie, Wan-Zhen; Zhang, Jun-Feng; Wang, Wei

    2009-09-18

    Ultrasound-assisted dispersive liquid-liquid microextraction coupled with high-performance liquid chromatography-fluorescence detection was used for the extraction and determination of three biogenic amines including octopamine, tyramine and phenethylamine in rice wine samples. Fluorescence probe 2,6-dimethyl-4-quinolinecarboxylic acid N-hydroxysuccinimide ester was applied for derivatization of biogenic amines. Acetonitrile and 1-octanol were used as disperser solvent and extraction solvent, respectively. Extraction conditions including the type of extraction solvent, the volume of extraction solvent, ultrasonication time and centrifuging time were optimized. After extraction and centrifuging, analyte was injected rapidly into high-performance liquid chromatography and then detected with fluorescence. The calibration graph of the proposed method was linear in the range of 5-500 microg mL(-1) (octopamine and tyramine) and 0.025-2.5 microg mL(-1) (phenethylamine). The relative standard deviations were 2.4-3.2% (n=6) and the limits of detection were in the range of 0.02-5 ng mL(-1). The method was applied to analyze the rice wine samples and spiked recoveries in the range of 95.42-104.56% were obtained. The results showed that ultrasound-assisted dispersive liquid-liquid microextraction was a very simple, rapid, sensitive and efficient analytical method for the determination of trace amount of biogenic amines.

  1. Rhamnolipid biosurfactant analysis using online turbulent flow chromatography-liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Behrens, Beate; Helmer, Patrick O; Tiso, Till; Blank, Lars M; Hayen, Heiko

    2016-09-23

    Rhamnolipids are biosurfactants produced by a variety of bacterial species that present a promising alternative to surfactants from petrochemical or oleochemical origin. The success of the fermentation is evaluated by subsequent qualitative and quantitative analysis. However, the sample preparation for high numbers of samples is often laborious and inefficient. In this study an online sample preparation is developed for the qualitative and quantitative analysis of rhamnolipids by LC-MS/MS. Online sample preparation is carried out on a TurboFlow Cyclone MAX column using turbulent flow chromatography. Sample preparation prior the analysis is minimized to a dilution and syringe filtration step leading to an instrumental analysis time of 33min. The limit of detection and the limit of quantification were 0.4ng and 0.6ng on column, respectively. Recovery of the main mono- and di-rhamnolipids from a fermentation sample was 102-104%. Additionally, the rhamnolipid biosynthetic precursors 3-hydroxy(alkanoyloxy)alkanoic acids (HAAs) are covered, albeit extraction is not quantitative (85-90%). The analysis of rhamnolipids from four different microbial species was in good agreement with previous reports. The presented method allows rapid and comprehensive analysis of rhamnolipids with minimal sample preparation directly from the fermentation broth. The application of complementary data-dependent MS/MS acquisition enables non-target screening of rhamnolipids.

  2. Ionic liquids for improving the extraction of NSAIDs in water samples using dispersive liquid-liquid microextraction by high performance liquid chromatography-diode array-fluorescence detection.

    Science.gov (United States)

    Toledo-Neira, Carla; Álvarez-Lueje, Alejandro

    2015-03-01

    A rapid, sensitive and efficient analytical method based on the use of ionic liquids for determination of non-steroidal anti-inflammatory drugs (NSAIDs) in water samples was developed. High-performance liquid chromatography equipped with a diode array and fluorescence detector was used for quantification of ketoprofen, ibuprofen and diclofenac in tap and river water samples. This new method relies on the use of two ionic liquids with multiple functionalities: one functions as an extraction solvent (1-butyl-3-methylimidazolium hexafluorophosphate ([BMIM][PF6]), and the other changes the polarity in the aqueous medium (1-butyl-3-methylimidazolium tetrafluoroborate, ([BMIM][BF4]). Factors such as the type and volume of the ILs and dispersive solvent, sample volume, and centrifugation time were investigated and optimized. The optimized method exhibited good precision, with relative standard deviation values between 2% and 3%, for the three NSAIDs. Limits of detection achieved for all of the analytes were between 17 and 95 ng mL(-1), and the recoveries ranged from 89% to 103%. Furthermore, the enrichment factors ranged from 49 to 57. The proposed method was successfully applied to the analysis of NSAIDs in tap and river water samples.

  3. Determination of preservatives in cosmetics, cleaning agents and pharmaceuticals using fast liquid chromatography.

    Science.gov (United States)

    Baranowska, Irena; Wojciechowska, Iwona; Solarz, Natalia; Krutysza, Ewa

    2014-01-01

    This paper reports the development of a method for simultaneously determining five preservatives in cosmetics, cleaning agents and pharmaceuticals by fast liquid chromatography. Methylisothiazolinone, methylchloroisothiazolinone, benzyl alcohol, sodium benzoate and methylparaben were separated on a Chromolith Fast Gradient reversed-phase 18e column using gradient elution with acetonitrile and a 0.1% aqueous solution of formic acid, with a run time of 3 min. The preparation of solid and liquid samples included ultrasonic extraction with methanol with recoveries ranging from 69 to 119%. The developed method was used to analyze samples of cosmetics (66 samples), cleaning agents (five samples) and pharmaceutical industry products (17 samples).

  4. Differentiation of mint (Mentha haplocalyx Briq.) from different regions in China using gas and liquid chromatography.

    Science.gov (United States)

    Dong, Wenjiang; Ni, Yongnian; Kokot, Serge

    2015-02-01

    In this study, complex substances such as Mint (Mentha haplocalyx Briq.) samples from different growing regions in China were analyzed for phenolic compounds by high-performance liquid chromatography with diode array detection and for the volatile aroma compounds by gas chromatography with mass spectrometry. Chemometrics methods, e.g. principal component analysis, back-propagation artificial neural networks, and partial least squares discriminant analysis, were applied to resolve complex chromatographic profiles of Mint samples. A total of 49 aroma components and 23 phenolic compounds were identified in 79 Mint samples. Principal component analysis score plots from gas chromatography with mass spectrometry and high-performance liquid chromatography with diode array detection data sets showed a clear distinction among Mint from three different regions in China. Classification results showed that satisfactory performance of prediction ability for back-propagation artificial neural networks and partial least squares discriminant analysis. The major compounds that contributed to the discrimination were chlorogenic acid, unknown 3, kaempherol 7-O-rutinoside, salvianolic acid L, hesperidin, diosmetin, unknown 6 and pebrellin in Mint according to regression coefficients of the partial least squares discriminant analysis model. This study indicated that the proposed strategy could provide a simple and rapid technique to distinguish clearly complex profiles from samples such as Mint.

  5. Contribution to the chromatography of atmospheric gases (1963); Contribution a la chromatographie des gaz de l'air (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Ghalamsiah, A. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1963-06-15

    In the first part, the author studies the gas-phase chromatographic separation of the atmospheric rare gases, of hydrogen, and of some gaseous compounds of carbon (CO, CO{sub 2}, CH{sub 4}) using inactive gases to obtain the most favourable operational conditions far this separation. In the second part, the optimum conditions for detecting non-active gases using an ionisation chamber and a {sup 239}Pu radioactive source emitting 5.15 MeV {alpha} particles are determined. (author) [French] Dans une premiere partie, l'auteur etudie la separation par chromatographie en phase gazeuse des gaz rares de l'air, de l'hydrogene, et de quelques composes gazeux du carbone (CO, CO{sub 2}, CH{sub 4}) en utilisant des gaz inactifs an vue d'obtenir les conditions experimenales les plus favorables en vue de cette separation. Dans une deuxieme partie, les conditions optimales de detection de gaz non actifs a l'aide d'une chambre d'ionisation, en utilisant comme source radioactive du {sup 239}Pu qui emet des particules {alpha} de 5,15 MeV, sont determinees. (auteur)

  6. Resolution of the stereoisomers of baclofen by high performance liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Weatherby, R.P.; Allan, R.D.; Johnston, G.A.R. (Sydney Univ. (Australia))

    1984-01-01

    The GABA analogue baclofen (3-(p-chlorophenyl)-4-aminobutanoic acid) has stereospecific actions on the peripheral and central nervous systems. This paper describes the resolution of tritium-labelled baclofen by high performance liquid chromatography on a reverse-phase C18 column using a chiral mobile phase. The method, which may have general application to certain other GABA analogues, affords optically pure (+)- and (-)-baclofen labelled with tritium to high specific activity suitable for ligand binding and other neurochemical studies.

  7. A simple high performance liquid chromatography method for determination of rebamipide in rat urine

    OpenAIRE

    Cooper, Dustin L.; Harirforoosh, Sam

    2014-01-01

    Rebamipide is a mucoprotective agent commonly used to prevent nonsteriodal anti-inflammatory drug-induced gastrointenstinal side effects [1]. Human plasma and urine analysis of rebamipide utilizing high performance liquid chromatography (HPLC) have been reported [2]. Recently, we reported on the plasma levels of rebamipide in presense or absence of celecoxib or diclofenac in rats [3] using a modified HPLC method of detection developed by Jeoung et al. [4]. To tailor the method towards use in ...

  8. Profiling and Quantitation of Bacterial Carotenoids by Liquid Chromatography and Photodiode Array Detection

    OpenAIRE

    1989-01-01

    An analytical method for the profiling and quantitative determination of carotenoids in bacteria is described. Exhaustive extraction of the pigments from four selected bacterial strains required treatment of the cells with potassium hydroxide or liquefied phenol or both before the addition of the extracting solvent (methanol or diethyl ether). The carotenoids in the extracts were separated by nonaqueous reversed-phase liquid chromatography in conjunction with photodiode array absorption detec...

  9. Quality Evaluation of Potentilla fruticosa L. by High Performance Liquid Chromatography Fingerprinting Associated with Chemometric Methods

    OpenAIRE

    Wei Liu; Dongmei Wang; Jianjun Liu; Dengwu Li; Dongxue Yin

    2016-01-01

    The present study was performed to assess the quality of Potentilla fruticosa L. sampled from distinct regions of China using high performance liquid chromatography (HPLC) fingerprinting coupled with a suite of chemometric methods. For this quantitative analysis, the main active phytochemical compositions and the antioxidant activity in P. fruticosa were also investigated. Considering the high percentages and antioxidant activities of phytochemicals, P. fruticosa samples from Kangding, Sichua...

  10. Determination of urinary metanephrine, normetanephrine and methoxymetanephrine by liquid chromatography-electrospray tandem mass spectrometry.

    OpenAIRE

    Le Goff, Caroline; Peeters, Stéphanie; NETCHACOVITCH, Matthieu; Kaux, Jean-François; CRINE, Yannick; Cavalier, Etienne

    2013-01-01

    Background: The aim of this work was to develop and validate a method for the determination of metanephrine (M), normetanephrine (NM) and methoxymetanephrine (METHO) in urine by liquid chromatography-tandem mass spectrometry (LCMS-MS) on the Triple Quad TQ 5500 from AB SCIEX. In fact, the determination of M and NM concentrations is used in clinical diagnosis of pheochromocytoma, a rare but potentially fatal tumor arising primarily from the chromaffin cells of the adrenal medulla. Meth...

  11. [Comparison of refractometric and ultraviolet detection methods in lactulose assay by high performance liquid chromatography].

    Science.gov (United States)

    Vaccher, C; Berthelot, P; Flouquet, N; Debaert, M

    1990-01-01

    Dosage of lactulose and determination of related sugars (lactose, fructose, galactose, épilactose) were undertaken by high performance liquid chromatography (HPLC). The present note described two modes of detection used simultaneously and compared: refractive index detector (RI) and multiwavelength ultraviolet detector (UV). HPLC is performed with an aminopropylsylil phase as stationary phase and an isocratic mobile phase containing acetonitrile and aqueous sodium phosphate. The results are outlined and discussed.

  12. Differentiation of coloured inks of inkjet printer cartridges by thin layer chromatography and high performance liquid chromatography.

    Science.gov (United States)

    Poon, N L; Ho, S S H; Li, C K

    2005-01-01

    Document examiners are frequently asked to determine whether or not a colour printout has originated from a particular inkjet printer. The printer can rarely be identified unless some unique defects or irregularities of the printer are present on the printout. However, it is possible to decipher the make and/or model of the printer by comparing the ink-profile of the questioned printout with that of a seized inkjet printer cartridge or from one in a database. This paper presents an overview of a systematic approach to characterising and discriminating the inks of different inkjet printer cartridges using thin layer chromatography (TLC) and high pressure liquid chromatography (HPLC) with multi-wavelength ultra-violet/visible (UV/Vis) detection. Ink samples from 23 different inkjet printer cartridges (including originals and substitutes) of different brands and colour printouts, printed by known printers were examined with newly developed chromatographic methods. Subsequently, a database of the ink-profiles was generated. The methods provide a useful tool for discriminating coloured inks in inkjet printer cartridges of different brands.

  13. Phytochemical Profile of Erythrina variegata by Using High-Performance Liquid Chromatography and Gas Chromatography-Mass Spectroscopy Analyses.

    Science.gov (United States)

    Muthukrishnan, Suriyavathana; Palanisamy, Subha; Subramanian, Senthilkumar; Selvaraj, Sumathi; Mari, Kavitha Rani; Kuppulingam, Ramalingam

    2016-08-01

    Natural products derived from plant sources have been utilized to treat patients with numerous diseases. The phytochemical constituents present in ethanolic leaf extract of Erythrina variegata (ELEV) were identified by using high-performance liquid chromatography (HPLC) and gas chromatography-mass spectroscopy (GC-MS) analyses. Shade dried leaves were powdered and extracted with ethanol for analyses through HPLC to identify selected flavonoids and through GC-MS to identify other molecules. The HPLC analysis of ELEV showed the presence of gallic and caffeic acids as the major components at concentrations of 2.0 ppm and 0.1 ppm, respectively, as well as other components. GC-MS analysis revealed the presence of 3-eicosyne; 3,7,11,15-tetramethyl-2-hexadecen-1-ol; butanoic acid, 3-methyl-3,7-dimethyl-6-octenyl ester; phytol; 1,2-benzenedicarboxylic acid, diundecyl ester; 1-octanol, 2-butyl-; squalene; and 2H-pyran, 2-(7-heptadecynyloxy) tetrahydro-derivative. Because pharmacopuncture is a new evolving natural mode that uses herbal extracts for treating patients with various ailments with minimum pain and maximum effect, the results of this study are particularly important and show that ELEV possesses a wide range of phytochemical constituents, as indicated above, as effective active principle molecules that can be used individually or in combination to treat patients with various diseases.

  14. Phytochemical Profile of Erythrina variegata by Using High-Performance Liquid Chromatography and Gas Chromatography-Mass Spectroscopy Analyses

    Directory of Open Access Journals (Sweden)

    Suriyavathana Muthukrishnan

    2016-08-01

    Full Text Available Natural products derived from plant sources have been utilized to treat patients with numerous diseases. The phytochemical constituents present in ethanolic leaf extract of Erythrina variegata (ELEV were identified by using high-performance liquid chromatography (HPLC and gas chromatography-mass spectroscopy (GC-MS analyses. Shade dried leaves were powdered and extracted with ethanol for analyses through HPLC to identify selected flavonoids and through GC-MS to identify other molecules. The HPLC analysis of ELEV showed the presence of gallic and caffeic acids as the major components at concentrations of 2.0 ppm and 0.1 ppm, respectively, as well as other components. GC-MS analysis revealed the presence of 3-eicosyne; 3,7,11,15-tetramethyl-2-hexadecen-1-ol; butanoic acid, 3-methyl-3,7-dimethyl-6-octenyl ester; phytol; 1,2-benzenedicarboxylic acid, diundecyl ester; 1-octanol, 2-butyl-; squalene; and 2H-pyran, 2-(7-heptadecynyloxy tetrahydro-derivative. Because pharmacopuncture is a new evolving natural mode that uses herbal extracts for treating patients with various ailments with minimum pain and maximum effect, the results of this study are particularly important and show that ELEV possesses a wide range of phytochemical constituents, as indicated above, as effective active principle molecules that can be used individually or in combination to treat patients with various diseases.

  15. Simultaneous achiral-chiral analysis of pharmaceutical compounds using two-dimensional reversed phase liquid chromatography-supercritical fluid chromatography.

    Science.gov (United States)

    Venkatramani, C J; Al-Sayah, Mohammad; Li, Guannan; Goel, Meenakshi; Girotti, James; Zang, Lisa; Wigman, Larry; Yehl, Peter; Chetwyn, Nik

    2016-02-01

    A new interface was designed to enable the coupling of reversed phase liquid chromatography (RPLC) and supercritical fluid chromatography (SFC). This online two-dimensional chromatographic system utilizing RPLC in the first dimension and SFC in the second was developed to achieve simultaneous achiral and chiral analysis of pharmaceutical compounds. The interface consists of an eight-port, dual-position switching valve with small volume C-18 trapping columns. The peaks of interest eluting from the first RPLC dimension column were effectively focused as sharp concentration pulses on small volume C-18 trapping column/s and then injected onto the second dimension SFC column. The first dimension RPLC separation provides the achiral purity result, and the second dimension SFC separation provides the chiral purity result (enantiomeric excess). The results are quantitative enabling simultaneous achiral, chiral analysis of compounds. The interface design and proof of concept demonstration are presented. Additionally, comparative studies to conventional SFC and case studies of the applications of 2D LC-SFC in pharmaceutical analysis is presented.

  16. Characterization of pitches by liquid chromatography using cellulose 3,5-dinitrobenzoate as the packing material

    Energy Technology Data Exchange (ETDEWEB)

    Arai, K.; Judo, R.; Ota, E. [Gunma University, Gunma (Japan). Dept. of Chemistry

    1997-08-01

    Characterization of coal tar, petroleum and PVC pitches by a liquid chromatography using cellulose 3,5-dinitrobenzoate (DNB-cellulose) as the packing material was investigated. Separation mechanism based on charge-transfer interaction between the dinitrobenzoyl group and polyaromatic compounds was expected to be useful for separation of the constituents of the pitches. First, 26 model polyaromatic compounds were tested to examine the characteristic feature of the packing material by liquid chromatography. The compounds were found to be classified roughly into four groups with different retention volume, principally according to the number of condensed rings. The nonplanar structure and aliphatic side chain of the polyaromatic compounds also affected the separation behavior. Both benzene soluble-hexane soluble and benzene soluble-hexane insoluble fractions of the three pitches were separated on DNB-cellulose. It was found that coal tar pitch contains relatively large amounts of some highly condensed polyaromatic compounds with condensed rings of 4 to 5; petroleum pitch has small amounts of such specific highly condensed polyaromatic compounds, while PVC pitch has large amounts of less condensed polyaromatic compounds and there is no significant amount of highly condensed compound in it. Thus DNB-cellulose was useful as the convenient packing material for liquid chromatography to characterize pitches.

  17. Recent development in liquid chromatography stationary phases for separation of Traditional Chinese Medicine components.

    Science.gov (United States)

    Jin, Hongli; Liu, Yanfang; Guo, Zhimou; Wang, Jixia; Zhang, Xiuli; Wang, Chaoran; Liang, Xinmiao

    2016-10-25

    Traditional Chinese Medicine (TCM) is an ancient medical practice which has been used to prevent and cure diseases for thousands of years. TCMs are frequently multi-component systems with mainly unidentified constituents. The study of the chemical compositions of TCMs remains a hotspot of research. Different strategies have been developed to manage the significant complexity of TCMs, in an attempt to determine their constituents. Reversed-phase liquid chromatography (RPLC) is still the method of choice for the separation of TCMs, but has many problems related to limited selectivity. Recently, enormous efforts have been concentrated on the development of efficient liquid chromatography (LC) methods for TCMs, based on selective stationary phases. This can improve the resolution and peak capacity considerably. In addition, high-efficiency stationary phases have been applied in the analysis of TCMs since the invention of ultra high-performance liquid chromatography (UHPLC). This review describes the advances in LC methods in TCM research from 2010 to date, and focuses on novel stationary phases. Their potential in the separation of TCMs using relevant applications is also demonstrated. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Comparison of liquid and supercritical fluid chromatography mobile phases for enantioselective separations on polysaccharide stationary phases.

    Science.gov (United States)

    Khater, Syame; Lozac'h, Marie-Anne; Adam, Isabelle; Francotte, Eric; West, Caroline

    2016-10-07

    Analysis and production of enantiomerically pure compounds is a major topic of interest when active pharmaceutical ingredients are concerned. Enantioselective chromatography has become a favourite both at the analytical and preparative scales. High-performance liquid chromatography (HPLC) and supercritical fluid chromatography (SFC) are dominating the scene and are often seen as complementary techniques. Nowadays, for economic and ecologic reasons, SFC may be preferred over normal-phase HPLC (NPLC) as it allows significant reductions in solvent consumption. However, the transfer of NPLC methods to SFC is not always straightforward. In this study, we compare the retention of achiral molecules and separation of enantiomers under supercritical fluid (carbon dioxide with ethanol or isopropanol) and liquid normal-phase (heptane with ethanol or isopropanol) elution modes with polysaccharide stationary phases in order to explore the differences between the retention and enantioseparation properties between the two modes. Chemometric methods (namely quantitative structure-retention relationships and discriminant analysis) are employed to compare the results obtained on a large set of analytes (171 achiral probes and 97 racemates) and gain some understanding on the retention and separation mechanisms. The results indicate that, contrary to popular belief, carbon dioxide - solvent SFC mobile phases are often weaker eluents than liquid mobile phases. It appears that SFC and NPLC elution modes provide different retention mechanisms. While some enantioseparations are unaffected, facilitating the transfer between the two elution modes, other enantioseparations may be drastically different due to different types and strength of interactions contributing to enantioselectivity.

  19. New Developments in Liquid Chromatography Mass Spectrometry for the Determination of Micropollutants

    Directory of Open Access Journals (Sweden)

    Zoraida Sosa-Ferrera

    2012-01-01

    Full Text Available The combination of liquid chromatography (LC with mass spectrometry (MS in the environmental field has appeared as a valuable tool for the determination of micropollutants. Several groups of compounds have been considered as particularly relevant (e.g., pharmaceuticals, hormones and other endocrine-disrupting, personal care products and their metabolites, flame retardants, surfactants, and plasticizers, among others since the same ones are continuously being released in the environment mainly as a result of the manufacturing processes, the disposal of unused or expired products, and the excreta. Because these micropollutants are not completely removed in the environment, very specific and sensitive analytical procedures are needed for their identification and quantification. High performance liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS (or LC-MS2 and especially time-of-flight mass spectrometry (TOF/MS, has allowed that many environmental contaminants that are highly polar or nonvolatile or have a high molecular weight to be analyzed or identified. In this work we present an overview focused on the developments of liquid chromatography mass spectrometry applied to the analysis of the main classes of micropollutants in aqueous and solid environmental samples. Various aspects of methodologies based on these techniques, including sample preparation (extraction/preconcentration and matrix effects, are discussed.

  20. Evaluation of a liquid chromatography method for quality control of methylated cyclodextrins.

    Science.gov (United States)

    Fougère, L; Elfakir, C; Lafosse, M

    2013-02-15

    Halo C18 column (fused core particles) and Chromolith RP18 column (monolith) were evaluated in liquid chromatography in order to analyze methylated-β-cyclodextrins (Me-β-CD) with various degrees of substitution, DS such as the number of methyl groups per cyclodextrin ring. Chromolith RP18 enables a performing analysis of Me-β-CD with low DS but is not suitable for dimethyl-β-cyclodextrins (DM-β-CD). On the other hand, Halo C18 column allows an improved fingerprint of CDs having a DS from 4.9 up to a value major than 14 and avoiding the use of various chromatographic systems. Thus, liquid chromatography performed with this column and an evaporative light scattering detector can be used as a generic system for methylated CD analysis. Moreover, fused core particles of Halo C18 column enables a rapid analysis and liquid chromatography coupled with electrospray-mass spectrometry appears as a powerful tool to determine co-elution and to characterize various isomers of complex methylated-β-cyclodextrin mixtures.

  1. Isolation and purification of heroin from heroin street samples by preparative high performance liquid chromatography.

    Science.gov (United States)

    Guo, Zhen; Zheng, Hui; Lu, Yanzhen; Wei, Yun

    2012-09-10

    The present study established a novel method using preparative high performance liquid chromatography to isolate and purify heroin·HCl from heroin street samples to be used as a reference standard. Different kinds of mobile phases and columns were used, ultimately the mobile phase consisting of hexane-isopropanol-methanol (65:28:7, v/v) and the SIL preparative column prepared in laboratory were selected as the final condition. Heroin was further purified by the drowning-out crystallization method using isopropanol-methanol (50:1, v/v) and hexane as drowning-out anti-solvents and salting-out agents, respectively. The purity was assessed by analytical high performance liquid chromatography and the confirmation of the chemical structure was performed by IR and NMR. About 110.7mg of heroin·HCl at a purity of over 99.52% was obtained from 180mg of heroin street samples which contained 156.15mg of heroin·HCl component by preparative high performance liquid chromatography. This method is suitable for preparing heroin standards in forensic science area.

  2. Surveillance of the Army’s Propellant Stockpile: Analysis of Stabilizer Content by High Performance Liquid Chromatography

    Science.gov (United States)

    1990-10-01

    high performance liquid chromatography to monitor the level of stabilizer and its daughter products in propellant. Three of those methods are presented along with statistics and some comments about their

  3. HIGH PERFORMANCE LIQUID CHROMATOGRAPHY OF COBALT(III) MIXED LIGAND COMPLEXES WITH ACETYLACETONATE AND OXINATE AND MONOMETHYLOXINATE IONS

    National Research Council Canada - National Science Library

    Kidani, Yoshinori; Naga, Shinobu; Koike, Hisashi

    1976-01-01

    In the presence of Co(III) mixed ligand complexes with acetylacetonate, and oxinate and monomethyloxinate ions, the authors attempted to employ high performance liquid chromatography, HPLC, for the separation and purification...

  4. Quantitative determination of paralytic shellfish poisoning toxins in shellfish using prechromatography oxidation and liquid chromatography with fluorescence detection: interlaboratory study

    NARCIS (Netherlands)

    Lawrence, J.F.; Niedzwiadek, B.; Menard, C.; Wezenbeek, P.

    2004-01-01

    An interlaboratory study was conducted for the determination of paralytic shellfish poisoning (PSP) toxins in shellfish. The method used liquid chromatography with fluorescence detection after prechromatographic oxidation of the toxins with hydrogen peroxide and periodate. The PSP toxins studied

  5. Chromatographic behavior of small organic compounds in low-temperature high-performance liquid chromatography using liquid carbon dioxide as the mobile phase.

    Science.gov (United States)

    Motono, Tomohiro; Nagai, Takashi; Kitagawa, Shinya; Ohtani, Hajime

    2015-07-01

    Low-temperature high-performance liquid chromatography, in which a loop injector, column, and detection cell were refrigerated at -35ºC, using liquid carbon dioxide as the mobile phase was developed. Small organic compounds (polyaromatic hydrocarbons, alkylbenzenes, and quinones) were separated by low-temperature high-performance liquid chromatography at temperatures from -35 to -5ºC. The combination of liquid carbon dioxide mobile phase with an octadecyl-silica (C18 ) column provided reversed phase mode separation, and a bare silica-gel column resulted in normal phase mode separation. In both the cases, nonlinear behavior at approximately -15ºC was found in the relationship between the temperature and the retention factors of the analytes (van't Hoff plots). In contrast to general trends in high-performance liquid chromatography, the decrease in temperature enhanced the separation efficiency of both the columns.

  6. Analysis of macrolide antibiotics, using liquid chromatography-mass spectrometry, in food, biological and environmental matrices.

    Science.gov (United States)

    Wang, Jian

    2009-01-01

    Macrolides are a group of antibiotics that have been widely used in human medical and veterinary practices. Analysis of macrolides and related compounds in food, biological, and environmental matrices continue to be the focus of scientists for the reasons of food safety, pharmacokinetic studies, and environmental concerns. This article presents an overview on the primary biological properties of macrolides and their associated analytical issues, including extraction, liquid chromatography-mass spectrometry (LC-MS), method validation, and measurement uncertainty. The main techniques that have been used to extract macrolides from various matrices are solid-phase extraction and liquid-liquid extraction. Conventional liquid chromatography (LC) with C18 columns plays a dominant role for the determination of macrolides, whereas ultra-performance liquid chromatography (UPLC) along with sub-2 microm particle C18 columns reduces run time and improves sensitivity. Mass spectrometry (MS), serving as a universal detection technique, has replaced ultraviolet (UV), fluorometric, and electrochemical detection for multi-macrolide analysis. The triple-quadrupole (QqQ), quadrupole ion trap (QIT), triple-quadrupole linear ion trap, time-of-flight (TOF), and quadrupole time-of-flight (QqTOF) mass spectrometers are current choices for the determination of macrolides, including quantification, confirmation, identification of their degradation products or metabolites, and structural elucidation. LC or UPLC coupled to a triple-quadrupole mass spectrometer operated in the multiple-reaction monitoring (MRM) mode (LC/MS/MS) is the first choice for quantification. UPLC-TOF or UPLC-QqTOF has been recognized as an emerging technique for accurate mass measurement and unequivocal identification of macrolides and their related compounds.

  7. Preparation and Characterization of a Polymeric Monolithic Column for Use in High-Performance Liquid Chromatography (HPLC)

    Science.gov (United States)

    Bindis, Michael P.; Bretz, Stacey Lowery; Danielson, Neil D.

    2011-01-01

    The high-performance liquid chromatography (HPLC) experiment, most often done in the undergraduate analytical instrumentation laboratory course, generally illustrates reversed-phase chromatography using a commercial C[subscript]18 silica column. To avoid the expense of periodic column replacement and introduce a choice of columns with different…

  8. Direct solid-phase microextraction combined with gas and liquid chromatography for the determination of lidocaine in human urine

    NARCIS (Netherlands)

    Koster, E.H M; Hofman, N.S K; de Jong, G.J.

    1998-01-01

    Solid-phase microextraction (SPME) has been combined with gas chromatography (GC) and liquid chromatography (LC) for the determination of lidocaine in human urine. A polydimethylsiloxane (PDMS) coated fibre was directly immersed into buffered urine. Extraction conditions such as time, pH, ionic stre

  9. Determination of polar organophosphorus pesticides in vegetables and fruits using liquid chromatography with tandem mass spectrometry: Selection of extraction solvent

    NARCIS (Netherlands)

    Mol, H.G.J.; Dam, R.C.J. van; Steijger, O.M.

    2003-01-01

    A method based on liquid chromatography (LC)-mass spectrometry (MS)/MS was developed for sensitive determination of a number of less gas chromatography (GC)-amenable organophosphorus pesticides (OPs; acephate, methamidophos, monocrotophos, omethoate, oxydemeton-methyl and vamidothion) in cabbage and

  10. Determination of polar organophosphorus pesticides in vegetables and fruits using liquid chromatography with tandem mass spectrometry: Selection of extraction solvent

    NARCIS (Netherlands)

    Mol, H.G.J.; Dam, R.C.J. van; Steijger, O.M.

    2003-01-01

    A method based on liquid chromatography (LC)-mass spectrometry (MS)/MS was developed for sensitive determination of a number of less gas chromatography (GC)-amenable organophosphorus pesticides (OPs; acephate, methamidophos, monocrotophos, omethoate, oxydemeton-methyl and vamidothion) in cabbage and

  11. Preparation and Characterization of a Polymeric Monolithic Column for Use in High-Performance Liquid Chromatography (HPLC)

    Science.gov (United States)

    Bindis, Michael P.; Bretz, Stacey Lowery; Danielson, Neil D.

    2011-01-01

    The high-performance liquid chromatography (HPLC) experiment, most often done in the undergraduate analytical instrumentation laboratory course, generally illustrates reversed-phase chromatography using a commercial C[subscript]18 silica column. To avoid the expense of periodic column replacement and introduce a choice of columns with different…

  12. tRNA separation by high-performance liquid chromatography using an aggregate of ODS-Hypersil and trioctylmethylammonium chloride

    NARCIS (Netherlands)

    Bischoff, Rainer; Graeser, E.; Mclaughlin, L.W.

    1983-01-01

    High-performance liquid chromatography on a reversed-phase support treated with a tetraalkylammonium salt was used to separate tRNAs from baker's yeast. While resolution by this column appears to result from both anion-exchange and reversed-phase chromatography, it is the hydrophobic interactions wh

  13. A New Liquid Chromatography-Tandem Mass Spectrometry Method for Determination of Bisoprolol in Human Plasma Samples

    OpenAIRE

    Gabriela Peste; Nela Bibire; Mihai Apostu; Aurel Vlase; Corneliu Oniscu

    2009-01-01

    Liquid chromatography (LC) coupled with mass spectrometry (MS) detection is one of the most powerful analytical tools for organic compound analysis. The advantages of using LC/MS methods over HPLC methods include: selectivity, chromatographic integrity, peak assignment, structural information, and rapid method development. In this paper, a new liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the determination of bisoprolol in human plasma s...

  14. Preparative isolation and analysis of alcohol dehydrogenase inhibitors from Glycyrrhiza uralensis root using ultrafiltration combined with high-performance liquid chromatography and high-speed countercurrent chromatography.

    Science.gov (United States)

    Chen, Miao; Liu, Liangliang; Chen, Xiaoqing

    2014-07-01

    A simple, rapid, and effective assay based on ultrafiltration combined with high-performance liquid chromatography and high-speed countercurrent chromatography was developed for screening and purifying alcohol dehydrogenase inhibitors from Glycyrrhiza uralensis root extract. Experiments were carried out to optimize binding conditions including alcohol dehydrogenase concentration, incubation time, temperature, and pH. By comparing the chromatograms, three compounds were found possessing alcohol dehydrogenase binding activity in Glycyrrhiza uralensis root. Under the target-guidance of ultrafiltration combined with the high-performance liquid chromatography experiment, liquiritin (1), isoliquiritin (2), and liquiritigenin (3) were separated by high-speed countercurrent chromatography using ethyl acetate/methanol/water (5:1:4) as the solvent system. The alcohol dehydrogenase inhibitory activities of these three isolated compounds were assessed; compound 2 showed strongest inhibitory activity with an IC50 of 8.95 μM. The results of the present study indicated that the combinative method using ultrafiltration, high-performance liquid chromatography and high-speed countercurrent chromatography could be widely applied for the rapid screening and isolation of enzyme inhibitors from complex mixtures.

  15. Incorporation of ionic liquid into porous polymer monoliths to enhance the separation of small molecules in reversed-phase high-performance liquid chromatography.

    Science.gov (United States)

    Wang, Jiafei; Bai, Ligai; Wei, Zhen; Qin, Junxiao; Ma, Yamin; Liu, Haiyan

    2015-06-01

    An ionic liquid was incorporated into the porous polymer monoliths to afford stationary phases with enhanced chromatographic performance for small molecules in reversed-phase high-performance liquid chromatography. The effect of the ionic liquid in the polymerization mixture on the performance of the monoliths was studied in detail. While monoliths without ionic liquid exhibited poor resolution and low efficiency, the addition of ionic liquid to the polymerization mixture provides highly increased resolution and high efficiency. The chromatographic performances of the monoliths were demonstrated by the separations of various small molecules including aromatic hydrocarbons, isomers, and homologues using a binary polar mobile phase. The present column efficiency reached 27 000 plates/m, which showed that the ionic liquid monoliths are alternative stationary phases in the separation of small molecules by high-performance liquid chromatography.

  16. Determination of nitrofuran metabolites in shrimp by high performance liquid chromatography with fluorescence detection and liquid chromatography-tandem mass spectrometry using a new derivatization reagent.

    Science.gov (United States)

    Du, Na-Na; Chen, Ming-Ming; Sheng, Liang-Quan; Chen, Shui-Sheng; Xu, Hua-Jie; Liu, Zhao-Di; Song, Chong-Fu; Qiao, Rui

    2014-01-31

    A high performance liquid chromatography with fluorescence detection (HPLC-FLD) method for the simultaneous determination of total nitrofuran metabolite residues (furazolidone, furaltadone, nitrofurantoin, and nitrofurazone) in shrimp was developed. The method involves the acid hydrolysis of protein-bound metabolites, followed by the derivatization of the freed metabolites with the new fluorescent derivatization reagent 2-hydroxy-1-naphthaldehyde (HN) and subsequent liquid-liquid extraction (LLE). Separation is achieved on a YMC-Pack Polymer C18 column under alkaline conditions, and the high fluorescence intensity of the derivatives at an emission wavelength Em=463nm (Ex=395nm) enables, for the first time, their simultaneous determination in shrimp at concentrations as low as 1μg/kg by HPLC-FLD. The method was validated using blank shrimp fortified with all four metabolites at 0.5, 1.0 and 2.0μg/kg. Recoveries were >87% with relative standard deviations of HPLC-FLD were in very good agreement with those obtained by LC-MS/MS analysis.

  17. Discussions about high performance liquid chromatography upgrading to ion chromatography%液相色谱升级改造为离子色谱问题探讨

    Institute of Scientific and Technical Information of China (English)

    施超欧; 马浩; 姚宝龙; 黄彩勇

    2014-01-01

    离子色谱作为色谱的一个分支,在原理和仪器结构上与液相色谱密切相关。本文总结了液相色谱升级为离子改造色谱的经验。%As a part of chromatography ,the functions and structures of instruments between high per-formance liquid chromatography and ion chromatography are closely related .In this paper ,HPLC upgra-ded to IC was discused .

  18. Rapid resolution liquid chromatography-mass spectrometry and high-performance liquid chromatography-fluorescence detection for metabolism and pharmacokinetic studies of ergosta-4,6,8(14),22-tetraen-3-one.

    Science.gov (United States)

    Zhao, Ying-Yong; Qin, Xiang-Yang; Cheng, Xian-Long; Liu, Xue-Ying; Lin, Rui-Chao; Zhang, Yongmin; Li, Xiao-Ye; Sun, Xiao-Li; Sun, Wen-Ji

    2010-08-24

    Ergosta-4,6,8(14),22-tetraen-3-one (ergone) from many medicinal plants has been demonstrated to possess a variety of pharmacological activities in vivo and in vitro, including cytotoxic, diuretic and immunosuppressive activity. Metabolism and pharmacokinetic studies on rat were conducted for ergone. Rapid resolution liquid chromatography with atmospheric pressure chemical ionization tandem multi-stage mass spectrometry (RRLC-APCI-MS(n)) and high-performance liquid chromatography with fluorescence detection (HPLC-FLD) methods were applied for the identification and quantification of ergone and its metabolite from rat plasma, faeces and urine. A metabolite was identified by RRLC-DAD-APCI-MS(n): 22,23-epoxy-ergosta-4,6,8(14)-triaen-3-one (epoxyergone). The concentrations of the analyte with its metabolites were determined by HPLC-FLD at excitation wavelength of 370 nm and emission wavelength of 485 nm. The samples were deproteinized with methanol after addition of camptothecin as internal standard (IS). The analysis was performed on a Diamonsil C18 column (150 mm x 4.6 mm x 5 microm) with a mobile phase gradient consisting of methanol and water at a flow rate of 1 mL min(-1). The assay was linear over the concentration range of 42-1500, 36-7500 and 42-1500 ng mL(-1) for plasma, faecal homogenate and urine respectively. The absolute recoveries were found to be 97.0+/-1.2%, 98.1+/-0.7% and 96.6+/-1.8% for plasma, faecal homogenate and urine respectively. The intra-day and inter-day relative standard deviations (RSD) were less than 10%. The previous HPLC-MS/MS method is not affordable for most laboratories because of the specialty requirement and high equipment cost. However, the HPLC-FLD method is economic and operating simply for quantitative determination of ergone and its metabolite in rat plasma, faeces and urine. In addition, liquid chromatography coupled with ion trap multi-stage mass spectrometry is becoming a useful technique for ergone metabolite identification.

  19. Atmospheric pressure plasma jets interacting with liquid covered tissue: touching and not-touching the liquid

    Science.gov (United States)

    Norberg, Seth A.; Tian, Wei; Johnsen, Eric; Kushner, Mark J.

    2014-11-01

    In the use of atmospheric pressure plasma jets in biological applications, the plasma-produced charged and neutral species in the plume of the jet often interact with a thin layer of liquid covering the tissue being treated. The plasma-produced reactivity must then penetrate through the liquid layer to reach the tissue. In this computational investigation, a plasma jet created by a single discharge pulse at three different voltages was directed onto a 200 µm water layer covering tissue followed by a 10 s afterglow. The magnitude of the voltage and its pulse length determined if the ionization wave producing the plasma plume reached the surface of the liquid. When the ionization wave touches the surface, significantly more charged species were created in the water layer with H3O+aq, O3-aq, and O2-aq being the dominant terminal species. More aqueous OHaq, H2O2aq, and O3aq were also formed when the plasma plume touches the surface. The single pulse examined here corresponds to a low repetition rate plasma jet where reactive species would be blown out of the volume between pulses and there is not recirculation of flow or turbulence. For these conditions, NxOy species do not accumulate in the volume. As a result, aqueous nitrites, nitrates, and peroxynitrite, and the HNO3aq and HOONOaq, which trace their origin to solvated NxOy, have low densities.

  20. Extraction and determination of hormones in cosmetics by homogeneous ionic liquid microextraction high-performance liquid chromatography.

    Science.gov (United States)

    Kang, Mingqin; Sun, Shuo; Li, Na; Zhang, Daihui; Chen, Mingyan; Zhang, Hanqi

    2012-08-01

    The homogeneous ionic liquid microextraction was applied to the extraction of hormones from cosmetics and the hormones were determined by high-performance liquid chromatography. 1-Hexyl-3-methylimidazolium tetrafluoroborate was used as extraction solvent. Ammonium hexafluorophosphate as used as ion-pairing agent. Several experimental parameters, including the volume of 1-hexyl-3-methylimidazolium tetrafluoroborate, amount of ammonium hexafluorophosphate and sodium chloride, extraction and centrifuge time, and the pH value, were optimized. The limits of detection and quantification for the analytes ranged from 0.03 to 0.24 ng/mL and from 0.10 to 0.79 ng/mL, respectively. The precision for determining the hormones was lower than 5.2%. The proposed method was successfully developed for the determination of hormones in real cosmetic samples.

  1. Determination of Four Pesticides in Soil by Homogeneous Ionic Liquid-based Microextraction Coupled with High-performance Liquid Chromatography

    Institute of Scientific and Technical Information of China (English)

    YAN Rui; SHAO Ming-yuan; LIANG Zhen-fen; ZHANG Han-qi; YU Ai-min

    2013-01-01

    Homogeneous ionic liquid microextraction was developed for the simultaneceus extraction of dimethomorph,mefenacet,isoprothiolane and oxadiazon from soil.1-Butyl-3-methylimidazolium tetrafluoroborate was used as extraction solvent,and ammonium hexafluorophosphate was used as ion-pairing agent.High-performance liquid chromatography(HPLC) was employed for separation and determination of the analytes.The calibration curves show good linear relationship(r>0.9988).The recoveries are between 74.2% and 97.9% with relative standard deviations(RSDs) lower than 5.97%.The present method is free of volatile organic solvents,and expenditures of sample,extraction time and solvent are lower,compared with ultrasonic and Soxhlet extraction.There was no obvious difference in the extraction recoveries of pesticides obtained by the three extraction methods.

  2. Determination of parabens in serum by liquid chromatography-tandem mass spectrometry: Correlation with lipstick use.

    Science.gov (United States)

    Tahan, Gabriella Padovani; Santos, Nayara de Kássia Souza; Albuquerque, Ana Carolina; Martins, Isarita

    2016-08-01

    Parabens are the most widely used preservative and are considered to be relatively safe compounds. However, studies have demonstrated that they may have estrogenic activity, and there is ongoing debate regarding the safety and potential cancer risk of using products containing these compounds. In the present work, liquid chromatography-tandem mass spectrometry was applied to determine methylparaben and propylparaben concentrations in serum, and the results were correlated with lipstick application. Samples were analyzed using liquid-liquid extraction, followed by liquid chromatography-tandem mass spectrometry. The validation results demonstrated the linearity of the method over a range of 1-20 ng/mL, in addition to the method's precision and accuracy. A statistically significant difference was demonstrated between serum parabens in women who used lipstick containing these substances compared with those not using this cosmetic (p = 0.0005 and 0.0016, respectively), and a strong association was observed between serum parabens and lipstick use (Spearman correlation = 0.7202). Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Deformation and degradation of polymers in ultra-high-pressure liquid chromatography.

    Science.gov (United States)

    Uliyanchenko, Elena; van der Wal, Sjoerd; Schoenmakers, Peter J

    2011-09-28

    Ultra-high-pressure liquid chromatography (UHPLC) using columns packed with sub-2 μm particles has great potential for separations of many types of complex samples, including polymers. However, the application of UHPLC for the analysis of polymers meets some fundamental obstacles. Small particles and narrow bore tubing in combination with high pressures generate significant shear and extensional forces in UHPLC systems, which may affect polymer chains. At high stress conditions flexible macromolecules may become extended and eventually the chemical bonds in the molecules can break. Deformation and degradation of macromolecules will affect the peak retention and the peak shape in the chromatogram, which may cause errors in the obtained results (e.g. the calculated molecular-weight distributions). In the present work we explored the limitations of UHPLC for the analysis of polymers. Degradation and deformation of macromolecules were studied by collecting and re-injecting polymer peaks and by off-line two-dimensional liquid chromatography. Polystyrene standards with molecular weight of 4 MDa and larger were found to degrade at UHPLC conditions. However, for most polymers degradation could be avoided by using low linear velocities. No degradation of 3-MDa PS (and smaller) was observed at linear velocities up to 7 mm/s. The column frits were implicated as the main sources of polymer degradation. The extent of degradation was found to depend on the type of the column and on the column history. At high flow rates degradation was observed without a column being installed. We demonstrated that polymer deformation preceded degradation. Stretched polymers eluted from the column in slalom chromatography mode (elution order opposite to that in SEC or HDC). Under certain conditions we observed co-elution of large and small PS molecules though a convolution of slalom chromatography and hydrodynamic chromatography.

  4. Ionic liquid foam floatation coupled with ionic liquid dispersive liquid-liquid microextraction for the separation and determination of estrogens in water samples by high-performance liquid chromatography with fluorescence detection.

    Science.gov (United States)

    Zhang, Rui; Wang, Chuanliu; Yue, Qiaohong; Zhou, Tiecheng; Li, Na; Zhang, Hanqi; Hao, Xiaoke

    2014-11-01

    An ionic liquid foam floatation coupled with ionic liquid dispersive liquid-liquid microextraction method was proposed for the extraction and concentration of 17-α-estradiol, 17-β-estradiol-benzoate, and quinestrol in environmental water samples by high-performance liquid chromatography with fluorescence detection. 1-Hexyl-3-methylimidazolium tetrafluoroborate was applied as foaming agent in the foam flotation process and dispersive solvent in microextraction. The introduction of the ion-pairing and salting-out agent NH4 PF6 was beneficial to the improvement of recoveries for the hydrophobic ionic liquid phase and analytes. Parameters of the proposed method including concentration of 1-hexyl-3-methylimidazolium tetrafluoroborate, flow rate of carrier gas, floatation time, types and concentration of ionic liquids, salt concentration in samples, extraction time, and centrifugation time were evaluated. The recoveries were between 98 and 105% with relative standard deviations lower than 7% for lake water and well water samples. The isolation of the target compounds from the water was found to be efficient, and the enrichment factors ranged from 4445 to 4632. This developing method is free of volatile organic solvents compared with regular extraction. Based on the unique properties of ionic liquids, the application of foam floatation, and dispersive liquid-liquid microextraction was widened.

  5. Comprehensive two-dimensional liquid chromatography with on-line Fourier-transform-infrared-spectroscopy detection for the characterization of copolymers

    NARCIS (Netherlands)

    Kok, S.J.; Hankemeier, T.; Schoenmakers, P.J.

    2005-01-01

    The on-line coupling of comprehensive two-dimensional liquid chromatography (liquid chromatography × size-exclusion chromatography, LC × SEC) and infrared (IR) spectroscopy has been realized by means of an IR flow cell. The system has been assessed by the functional-group analysis of a series of

  6. Comprehensive two-dimensional liquid chromatography with on-line Fourier-transform-infrared-spectroscopy detection for the characterization of copolymers

    NARCIS (Netherlands)

    Kok, S.J.; Hankemeier, T.; Schoenmakers, P.J.

    2005-01-01

    The on-line coupling of comprehensive two-dimensional liquid chromatography (liquid chromatography × size-exclusion chromatography, LC × SEC) and infrared (IR) spectroscopy has been realized by means of an IR flow cell. The system has been assessed by the functional-group analysis of a series of sty

  7. Multimycotoxin analysis in water and fish plasma by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Tolosa, J; Font, G; Mañes, J; Ferrer, E

    2016-02-01

    High performance liquid chromatography-mass spectrometry was used for the determination of 15 mycotoxins in water and fish plasma samples, including aflatoxins, fumonisins, ochratoxin A, sterigmatocistin, fusarenon-X and emerging Fusarium mycotoxins. In this work, dispersive liquid-liquid microextraction (DLLME) was assessed as a sample treatment for the simultaneous extraction of mycotoxins. Results showed differences in recovery assays when different extraction solvents were employed. Ethyl acetate showed better recoveries for the major part of mycotoxins analyzed, except for aflatoxins B2, G1 and G2, which showed better recoveries when employing chloroform as extractant solvent. Fumonisins and beauvericin exhibited low recoveries in both water and plasma. This method was validated according to guidelines established by European Commission and has shown to be suitable to be applied in dietary and/or toxicokinetic studies in fish where is necessary to check mycotoxin contents in rearing water and fish plasma.

  8. Preliminary Validation of High Performance Liquid Chromatography Method for Detection of Methyltestosterone Residue in Carp Muscle

    Institute of Scientific and Technical Information of China (English)

    JIANG Jie; LIN Hong; FU Xiaoting; LI Mingming

    2005-01-01

    The use of synthetic anabolic steroid methyltestosterone (MT) as growth promoter is prohibited in China. Validations of analytical methods for MT residue in food and the results obtained have become indispensable. The high performance liquid chromatography (HPLC) method for the detection of MT with liquid-liquid extraction by trichloromethanemethanol in carp muscle tissue was preliminarily validated with reference to the following parameters: recovery (accuracy)at the 1, 5 and 10 mgkg-1 level, between-run and within-run CV values (repeatability, also called relative standard deviation(RSD)) and limit of detection. The recoveries were above 80% and the between-run and within-run CV values below 10%for muscle tissue. The limit of detection was 0.05 mgkg-1.

  9. Use of ionic liquids as stationary phases in hyphenated gas chromatography techniques.

    Science.gov (United States)

    Ragonese, Carla; Sciarrone, Danilo; Tranchida, Peter Quinto; Dugo, Paola; Mondello, Luigi

    2012-09-14

    In the past decades a consistent number of ionic liquids have been specifically synthesized and evaluated as stationary phase in gas chromatography. Ionic liquid, also defined as "molten salts", are a class of organic non-molecular solvents liquid at room temperature (RTILs) that satisfy most of the requirements of a GC stationary phase, among which a high viscosity, the possibility to tune the selectivity (by changing the cation-anion combination) and a high thermal stability. The choice of the proper stationary phase plays a key role in the improvement/optimization of a GC method, and although the use of IL as stationary phases is still not well-established, the general interest in their applications has greatly increased, thanks to their particular properties. The present contribution provides an overview on recent evaluations and applications of IL stationary phases, focusing in particular on the use of these novel tools in hyphenated GC-based techniques.

  10. Analysis of Whiskey by Dispersive Liquid-Liquid Microextraction Coupled with Gas Chromatography/Mass Spectrometry: An Upper Division Analytical Chemistry Experiment Guided by Green Chemistry

    Science.gov (United States)

    Owens, Janel E.; Zimmerman, Laura B.; Gardner, Michael A.; Lowe, Luis E.

    2016-01-01

    Analysis of whiskey samples prepared by a green microextraction technique, dispersive liquid-liquid microextraction (DLLME), before analysis by a qualitative gas chromatography-mass spectrometry (GC/MS) method, is described as a laboratory experiment for an upper division instrumental methods of analysis laboratory course. Here, aroma compounds in…

  11. Screening anti-tumor compounds from Ligusticum wallichii using cell membrane chromatography combined with high-performance liquid chromatography and mass spectrometry.

    Science.gov (United States)

    Zhang, Tao; Ding, Yuanyuan; An, Hongli; Feng, Liuxin; Wang, Sicen

    2015-07-14

    Tyrosine 367 Cysteine-fibroblast growth factor receptor 4 cell membrane chromatography combined with high-performance liquid chromatography and mass spectrometry was developed. Tyrosine 367 Cysteine-HEK293 cells were used as cell membrane stationary phase. Specificity and reproducibility of the cell membrane chromatography was evaluated using 1-tert-butyl-3-{2-[4-(diethylamino)butylamino]-6-(3,5-dimethoxyphenyl)pyrido[2,3-d]pyrimidin-7-yl}urea, Nimodipine and dexamethasone acetate. Then, anti-tumor components acting on Tyrosine 367 Cysteine-fibroblast growth factor receptor 4 were screened and identified from extracts of Ligusticum wallichii. Components from the extract were retained on the cell membrane chromatographic column. The retained fraction was directly eluted into high-performance liquid chromatography with mass spectrometry system for separation and identification. Finally, Levistolide A was identified as an active component from Ligusticum wallichii extracts. The 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl-tetrazolium bromide-formazan colorimetric assay revealed that Levistolide A inhibits proliferation of overexpressing the mutated receptor cells with dose-dependent manner. Phosphorylation of fibroblast growth factor receptor 4 was also decrease under Levistolide A treatment. Flex dock simulation verified that Levistolide A could bind with the tyrosine kinase domain of fibroblast growth factor receptor 4. Therefore, Levistolide A screened by the cell membrane chromatography combined with high-performance liquid chromatography and mass spectrometry can arrest cell growth. In conclusion, the two-dimensional high-performance liquid chromatography method can screen and identify potential anti-tumor ingredients which specifically act on the tyrosine kinase domain of the mutated fibroblast growth factor receptor 4. This article is protected by copyright. All rights reserved.

  12. Home-made online hyphenation of pressurized liquid extraction, turbulent flow chromatography, and high performance liquid chromatography, Cistanche deserticola as a case study.

    Science.gov (United States)

    Song, Qingqing; Li, Jun; Liu, Xiao; Zhang, Yuan; Guo, Liping; Jiang, Yong; Song, Yuelin; Tu, Pengfei

    2016-03-18

    Incompatibility between the conventional pressurized liquid extraction (PLE) devices and high performance liquid chromatography (HPLC) extensively hinders direct and green chemical analysis of herbal materials. Herein, a facile PLE module was configured, and then it was online hyphenated with HPLC via a turbulent flow chromatography (TFC) column. Regarding PLE module, a long PEEK tube (0.13 × 1000 mm) was employed to generate desired pressure (approximately 13.0 MPa) when warm acidic water (70 °C) was delivered as extraction solvent at a high flow rate (2.5 mL/min), and a hollow guard column (3.0 × 4.0 mm) was implemented to hold crude materials. Effluent was collected from the outlet of PEEK tube, concentrated, and subjected onto HPLC coupled with hybrid ion trap-time of flight mass spectrometer to assess the extraction efficiency and also to profile the chemical composition of Cistanche deserticola (CD) that is honored as "Ginseng of the desert". Afterwards, a TFC column was introduced to accomplish online transmission of low molecule weight components from PLE module to HPLC coupled with diode array detection, and two electronic 6-port/2-channel valves were in charge of alternating the whole system between extraction (0-3.0 min) and elution (3.0-35.0 min) phases. Quantitative method was developed and validated for simultaneous determination of eight primary phenylethanoid glycosides in CD using online PLE-TFC-HPLC. All findings demonstrated that the home-made platform is advantageous at direct chemical analysis, as well as time-, solvent-, and material-savings, suggesting a robust tool for chemical fingerprinting of herbs.

  13. Determination of Alternaria mycotoxins in wine and juice using ionic liquid modified countercurrent chromatography as a pretreatment method followed by high-performance liquid chromatography.

    Science.gov (United States)

    Fan, Chen; Cao, Xueli; Liu, Man; Wang, Wei

    2016-03-04

    Alternariol (AOH), alternariol monomethyl ether (AME), and tenuazonic acid (TeA) are some of the main Alternaria mycotoxins that can be found as contaminants in food materials. The objective of this study was to develop a pretreatment method with countercurrent chromatography (CCC) for enrichment and cleanup of trace Alternaria mycotoxins in food samples prior to high-performance liquid chromatography (HPLC) analysis. An Analytical CCC instrument with a column volume 22.5mL was used, and a two-phase solvent system composed of ethyl acetate and water modified with 6% [HOOMIM][Cl] in mass to volume ratio was selected. Under the optimized CCC operation conditions, trace amounts of AOH, AME, and TeA in large volume of liquid sample were efficiently extracted and enriched in the stationary phase, and then eluted out just by reversing the stationary phase as mobile phase in the opposite flowing direction tail-to-head. The enrichment and elution strategies are unique and can be fulfilled online with high enrichment factors (87-114) and high recoveries (81.14-110.94%). The method has been successively applied to the determination of Alternaria mycotoxins in real apple juice and wine samples with the limits of detection (LOD) in the range of 0.03-0.14μgL(-1). Totally 12 wine samples and 15 apple juice samples from the local market were analyzed. The detection rate of AOH and AME in both kinds of the samples were more than 50%, while TeA was found in relatively high level of 1.75-49.61μgL(-1) in some of the apple juice samples. The proposed method is simple, rapid, and sensitive and could also be used for the analysis and monitoring of Alternaria mycotoxin in other food samples.

  14. [Qualitative and quantitative analysis of the amino acids in Rhizoma Arisaematis by ultra high performance liquid chromatography-tandem mass spectrometry and high performance liquid chromatography].

    Science.gov (United States)

    Wang, Xing; Chi, Yumei; Kang, An

    2014-12-01

    A method for the identification and determination of the polar amino components without ultraviolet activity in traditional Chinese medicines was developed. With Rhizoma Arisaematis as the object of this study, using pre-column derivatization with phenyl isothiocyanate (PITC) as the derivatization reagent, compounds were separated and identified on a C18 column (100 mm x 2.1 mm, 3.5 µm) by ultra high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). A total of 20 components, including 18 amino acids and 2 amine compounds were identified. Furthermore, after the optimization of the derivatization conditions, 15 amino acids were determined by high performance liquid chromatography (HPLC) on Diamonsil C18 column (250 mm x 4.6 mm, 5 µm), detected at 254 nm and gradiently eluted by acetonitrile and 0. 05 mol/L ammonium acetate-acetic acid (pH 6. 5) as the mobile phases. The results of methodological study demonstrated that the method can meet the requirements of the determination. All calibration curves expressed good linearity: Glu, Try in the range of 2-100 mg/L, Arg in the range of 6-300 mg/L, others in the range of 0. 8-40 µg/L, with the correlation coefficients ≥ 0. 999 5. The average recovery of this method was among 95%-105% and the RSD was less than 3%. The developed method was successfully applied to quantitative determination of amino compounds in 12 batches of Rhizoma Arisaematis samples. The method is simple, sensitive, accurate, and can be used for rapid identification and determination of amino components in traditional Chinese medicines.

  15. Improved sensitivity gas chromatography-mass spectrometry determination of parabens in waters using ionic liquids.

    Science.gov (United States)

    Cacho, Juan Ignacio; Campillo, Natalia; Viñas, Pilar; Hernández-Córdoba, Manuel

    2016-01-01

    A new procedure for the introduction of ionic liquid samples in gas chromatography (GC) is proposed. This procedure, based on microvial insert thermal desorption, allows the direct analysis of the compounds preconcentrated by ionic liquid based liquid-liquid microextraction (IL-LLME) using the combination of a thermal desorption unit (TDU) and a programmed temperature vaporization injector (PTV). Two different IL-LLME methodologies, one based on the formation of a microdroplet emulsion by dispersive liquid-liquid microextraction (DLLME) and other through ultrasound-assisted emulsification microextraction (USAEME) were studied and evaluated. IL-DLLME proved advantageous and consequently, it was adopted for preconcentration purposes. This easy to apply approach was used for the determination of five parabens (methyl-, ethyl-, propyl-, butyl- and isobutyl paraben) in swimming pool waters, after in situ acetylation. The optimized conditions of TDU/PTV allowed the analytes contained in 20 µL of the enriched IL to be transferred to the capillary column. Quantification of the samples was carried out against aqueous standards, and quantification limits of between 4.3 and 8.1 ng L(-1) were obtained, depending on the compound. Concentrations of between 9 and 47 ng L(-1) for some analytes were obtained in the analysis of ten samples.

  16. Development and comparison of two dispersive liquid-liquid microextraction techniques coupled to high performance liquid chromatography for the rapid analysis of bisphenol A in edible oils.

    Science.gov (United States)

    Liu, Shuhui; Xie, Qilong; Chen, Jie; Sun, Janzhi; He, Hui; Zhang, Xiaoke

    2013-06-21

    In this study, two novel sample extraction methods for the analysis of bisphenol A (BPA) in edible oils were developed by using liquid-liquid extraction followed by a dispersive liquid-liquid microextraction (LLE-DLLME) and reversed-phase dispersive liquid-liquid microextraction (RP-DLLME). RP-DLLME showed a superior characteristic over LLE-DLLME and other previously reported procedures because of its easy operation, short extraction time, high sensitivity, low organic solvent consumption and waste generation. The optimized extraction conditions of RP-DLLME for 1.0 g of edible oil diluted in 4 mL of n-hexane were: extractant, 100 μL 0.2 M sodium hydroxide solution (80% methanol, v/v); extraction time, 1 min; centrifugation, 3 min. The determination of BPA was carried out by high performance liquid chromatography coupled with a DAD detector. The method offered excellent linearity over a range of 0.010-0.5 μg g(-1) with a correlation coefficient of r>0.997. Intra-day and inter-day repeatability values expressed as relative standard deviation were 1.9% and 5.9%, respectively. The quantitation limit and detection limit were 6.3 and 2.5 ng g(-1). The target analyte was detected in 5 out of 16 edible oil samples. The recovery rates in real samples ranged from 89.5 to 99.7%.

  17. Ultrapreconcentration and determination of organophosphorus pesticides in water by solid-phase extraction combined with dispersive liquid-liquid microextraction and high-performance liquid chromatography.

    Science.gov (United States)

    Chen, Junhua; Zhou, Guangming; Deng, Yongli; Cheng, Hongmei; Shen, Jie; Gao, Yi; Peng, Guilong

    2016-01-01

    Solid-phase extraction coupled with dispersive liquid-liquid microextraction was developed as an ultra-preconcentration method for the determination of four organophosphorus pesticides (isocarbophos, parathion-methyl, triazophos and fenitrothion) in water samples. The analytes considered in this study were rapidly extracted and concentrated from large volumes of aqueous solutions (100 mL) by solid-phase extraction coupled with dispersive liquid-liquid microextraction and then analyzed using high performance liquid chromatography. Experimental variables including type and volume of elution solvent, volume and flow rate of sample solution, salt concentration, type and volume of extraction solvent and sample solution pH were investigated for the solid-phase extraction coupled with dispersive liquid-liquid microextraction with these analytes, and the best results were obtained using methanol as eluent and ethylene chloride as extraction solvent. Under the optimal conditions, an exhaustive extraction for four analytes (recoveries >86.9%) and high enrichment factors were attained. The limits of detection were between 0.021 and 0.15 μg/L. The relative standard deviations for 0.5 μg/L of the pesticides in water were in the range of 1.9-6.8% (n = 5). The proposed strategy offered the advantages of simple operation, high enrichment factor and sensitivity and was successfully applied to the determination of four organophosphorus pesticides in water samples.

  18. Identification of novel circulating coffee metabolites in human plasma by liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Redeuil, Karine; Smarrito-Menozzi, Candice; Guy, Philippe; Rezzi, Serge; Dionisi, Fabiola; Williamson, Gary; Nagy, Kornél; Renouf, Mathieu

    2011-07-22

    This study reports a liquid chromatography-mass spectrometry method for the detection of polyphenol-derived metabolites in human plasma without enzymatic treatment after coffee consumption. Separation of available standards was achieved by reversed-phase ultra performance liquid chromatography and detection was performed by high resolution mass spectrometry in negative electrospray ionization mode. This analytical method was then applied for the identification and relative quantification of circulating coffee metabolites. A total of 34 coffee metabolites (mainly reduced, sulfated and methylated forms of caffeic acid, coumaric acid, caffeoylquinic acid and caffeoylquinic acid lactone) were identified based on mass accuracy (<4 ppm for most metabolites), specific fragmentation pattern and co-chromatography (when standard available). Among them, 19 circulating coffee metabolites were identified for the first time in human plasma such as feruloylquinic acid lactone, sulfated and glucuronidated forms of feruloylquinic acid lactone and sulfated forms of coumaric acid. Phenolic acid derivatives such as dihydroferulic acid, dihydroferulic acid 4'-O-sulfate, caffeic acid 3'-O-sulfate, dimethoxycinnamic acid, dihydrocaffeic acid and coumaric acid O-sulfate appeared to be the main metabolites circulating in human plasma after coffee consumption. The described method is a sensitive and reliable approach for the identification of coffee metabolites in biological fluids. In future, this analytical method will give more confidence in compound identification to provide a more comprehensive assessment of coffee polyphenol bioavailability studies in humans.

  19. Determination of eight fluoroquinolones in groundwater samples with ultrasound-assisted ionic liquid dispersive liquid-liquid microextraction prior to high-performance liquid chromatography and fluorescence detection.

    Science.gov (United States)

    Vázquez, M M Parrilla; Vázquez, P Parrilla; Galera, M Martínez; García, M D Gil

    2012-10-20

    An ultrasound-assisted ionic liquid dispersive liquid-liquid microextraction (US-IL-DLLME) procedure was developed for the extraction of eight fluoroquinolones (marbofloxacin, norfloxacin, ciprofloxacin, lomefloxacin, danofloxacin, enrofloxacin, oxolinic acid and nalidixic acid) in groundwater, using high-performance liquid chromatography with fluorescence detection (HPLC-FD). The ultrasound-assisted process was applied to accelerate the formation of the fine cloudy solution using a small volume of disperser solvent (0.4 mL of methanol), which increased the extraction efficiency and reduced the equilibrium time. For the DLLME procedure, the IL 1-octyl-3-methylimidazolium hexafluorophosphate ([C(8)MIM] [PF(6)]) and methanol (MeOH) were used as extraction and disperser solvent, respectively. By comparing [C(8)MIM] [PF(6)] with 1-hexyl-3-methylimidazolium hexafluorophosphate ([C(6)MIM] [PF(6)]) and 1-butyl-3-methylimidazolium hexafluorophosphate ([C(4)MIM] [PF(6)]) as extraction solvents, it was observed that when using [C(8)MIM] [PF(6)] the cloudy solution was formed more readily than when using [C(6)MIM] [PF(6)] or [C(4)MIM] [PF(6)]. The factors affecting the extraction efficiency, such as the type and volume of ionic liquid, type and volume of disperser solvent, cooling in ice-water, sonication time, centrifuging time, sample pH and ionic strength, were optimised. A slight increase in the recoveries of fluoroquinolones was observed when an ice-water bath extraction step was included in the analytical procedure (85-107%) compared to those obtained without this step (83-96%). Under the optimum conditions, linearity of the method was observed over the range 10-300 ng L(-1) with correlation coefficient >0.9981. The proposed method has been found to have excellent sensitivity with limit of detection between 0.8 and 13 ng L(-1) and precision with relative standard deviation values between 4.8 and 9.4% (RSD, n=5). Good enrichment factors (122-205) and recoveries (85

  20. Arabidopsis thaliana Polar Glycerolipid Profiling by Thin Layer Chromatography (TLC) Coupled with Gas-Liquid Chromatography (GLC)

    Science.gov (United States)

    Wang, Zhen; Benning, Christoph

    2011-01-01

    Biological membranes separate cells from the environment. From a single cell to multicellular plants and animals, glycerolipids, such as phosphatidylcholine or phosphatidylethanolamine, form bilayer membranes which act as both boundaries and interfaces for chemical exchange between cells and their surroundings. Unlike animals, plant cells have a special organelle for photosynthesis, the chloroplast. The intricate membrane system of the chloroplast contains unique glycerolipids, namely glycolipids lacking phosphorus: monogalactosyldiacylglycerol (MGDG), digalactosyldiacylglycerol (DGDG), sulfoquinovosyldiacylglycerol (SQDG)4. The roles of these lipids are beyond simply structural. These glycolipids and other glycerolipids were found in the crystal structures of photosystem I and II indicating the involvement of glycerolipids in photosynthesis8,11. During phosphate starvation, DGDG is transferred to extraplastidic membranes to compensate the loss of phospholipids9,12. Much of our knowledge of the biosynthesis and function of these lipids has been derived from a combination of genetic and biochemical studies with Arabidopsis thaliana14. During these studies, a simple procedure for the analysis of polar lipids has been essential for the screening and analysis of lipid mutants and will be outlined in detail. A leaf lipid extract is first separated by thin layer chromatography (TLC) and glycerolipids are stained reversibly with iodine vapor. The individual lipids are scraped from the TLC plate and converted to fatty acyl methylesters (FAMEs), which are analyzed by gas-liquid chromatography coupled with flame ionization detection (FID-GLC) (Figure 1). This method has been proven to be a reliable tool for mutant screening. For example, the tgd1,2,3,4 endoplasmic reticulum-to-plastid lipid trafficking mutants were discovered based on the accumulation of an abnormal galactoglycerolipid: trigalactosyldiacylglycerol (TGDG) and a decrease in the relative amount of 18:3 (carbons

  1. Preparative Isolation and Purification of Flavone C-Glycosides from the Leaves of Ficus microcarpa L. f by Medium-Pressure Liquid Chromatography, High-Speed Countercurrent Chromatography, and Preparative Liquid Chromatography.

    Science.gov (United States)

    Wang, Xiaohong; Liang, Yong; Zhu, Licai; Xie, Huichun; Li, Hang; He, Junting; Pan, Man; Zhang, Tianyou; Ito, Yoichiro

    2010-01-01

    Combined with medium-pressure liquid chromatography (MPLC) and preparative high-performance liquid chromatography (perp-HPLC), high-speed countercurrent chromatography (HSCCC) was applied for separation and purification of flavone C-glycosides from the crude extract of leaves of Ficus microcarpae L. f. HSCCC separation was performed on a two-phase solvent system composed of methyl tert- butyl ether - ethyl acetate - 1-butanol - acetonitrile - 0.1% aqueous trifluoroacetic acid at a volume ratio of 1:3:1:1:5. Partially resolved peak fractions from HSCCC separation were further purified by preparative HPLC. Four well-separated compounds were obtained and their purities were determined by HPLC. The purities of these peaks were 97.28%, 97.20%, 92.23%, and 98.40%.. These peaks were characterized by ESI-MS(n). According to the reference, they were identified as orientin (peak I), isovitexin-3″-O-glucopyranoside (peak II), isovitexin (peak III), and vitexin (peak IV), yielded 1.2 mg, 4.5 mg, 3.3 mg, and 1.8 mg, respectively.

  2. Ultrafiltration liquid chromatography combined with high-speed countercurrent chromatography for screening and isolating potential α-glucosidase and xanthine oxidase inhibitors from Cortex Phellodendri.

    Science.gov (United States)

    Li, Sainan; Liu, Chunming; Guo, Liping; Zhang, Yuchi; Wang, Jing; Ma, Bing; Wang, Yueqi; Wang, Yumeng; Ren, Junqi; Yang, Xiaojing; Qin, Yao; Tang, Ying

    2014-09-01

    Cortex Phellodendri is a typical Chinese herb with a large number of alkaloids existing in all parts of it. The most common methods for screening and isolating alkaloids are mostly labor intensive and time consuming. In this study, a new assay based upon ultrafiltration liquid chromatography was developed for the rapid screening of ligands for α-glucosidase and xanthine oxidase. The C. Phellodendri extract was found to contain two alkaloids with both α-glucosidase- and xanthine oxidase binding activities and one lactone with α-glucosidase-binding activity. Subsequently, with the help of high-speed countercurrent chromatography, the specific binding ligands including palmatine, berberine, and obaculactone with purities of 97.38, 96.12, and 96.08%, respectively, were successfully separated. An optimized low-toxicity two-phase solvent system composed of ethyl acetate/n-butanol/ethanol/water (3.5:1.7:0.5:5, v/v/v/v) was used to isolate the three compounds mentioned above from C. Phellodendri. The targeted compounds were identified by liquid chromatography coupled with mass spectrometry and NMR spectroscopy. Therefore, ultrafiltration liquid chromatography combined with high-speed countercurrent chromatography is not only a powerful tool for screening and isolating α-glucosidase and xanthine oxidase inhibitors in complex samples but is also a useful platform for discovering bioactive compounds for the prevention and treatment of diabetes mellitus and gout.

  3. Analysis of allergens in tubeimu saponin extracts by using rat basophilic leukemia 2H3 cell-based affinity chromatography coupled to liquid chromatography and mass spectrometry.

    Science.gov (United States)

    Zhang, Tao; Han, Shengli; Liu, Qi; Guo, Ying; He, Langchong

    2014-11-01

    An affinity two-dimensional chromatography method was developed for the recognition, separation, and identification of allergic components from tubeimu saponin extracts, a preparation often injected to treat various conditions as indicated by traditional Chinese medicine. Rat basophilic leukemia-2H3 cell membranes were used as the stationary phase of a membrane affinity chromatography column to capture components with affinity for mast cells that could be involved in a degranulation reaction. The retained components were enriched and analyzed by membrane affinity chromatography with liquid chromatography and mass spectrometry via a port switch valve. Suitability and reliability of the method was investigated using appropriate standards, and then, the method was applied to identify components retained from tubeimu saponin extracts. Tubeimoside A was identified in this way as a potential allergen, and degranulation assays confirmed that tubeimoside A induces RBL-2H3 cell degranulation in a dose-dependent manner. An increase in Ca(2+) influx indicated that degranulation induced by tubeimoside A is likely Ca(2+) dependent. Coupled with the degranulation assay, RBL-2H3 cell-based affinity chromatography coupled with liquid chromatography and mass spectrometry is an effective method for screening and identifying allergic components from tubeimu saponin extracts.

  4. 2-(2-Phenyl-1H-phenanthro-[9,10-d]imidazole-1-yl)-acetic acid (PPIA) and its application for determination of amines by high performance liquid chromatography with fluorescence detection and identification with mass spectroscopy/atmospheric pressure chemical ionization

    Energy Technology Data Exchange (ETDEWEB)

    You Jinmao [College of Chemistry Science, Qufu Normal University, Qufu Shandong 273165 (China)]. E-mail: Jmyou6304@163.com; Zhao Xianen [College of Chemistry Science, Qufu Normal University, Qufu Shandong 273165 (China); Suo Yourui [Northwest Plateau Institute of Biology, Chinese Academy of Sciences, Xining (China); Wang Honglun [Northwest Plateau Institute of Biology, Chinese Academy of Sciences, Xining (China); Li Yulin [Northwest Plateau Institute of Biology, Chinese Academy of Sciences, Xining (China); Sun Jing [Northwest Plateau Institute of Biology, Chinese Academy of Sciences, Xining (China)

    2006-04-21

    A simple, sensitive, and mild method for the determination of amino compounds based on a condensation reaction with 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide hydrochloride (EDC.HCl) as the dehydrant with fluorescence detection has been developed. Amines were derivatized to their acidamides with labeling reagent 2-(2-phenyl-1H-phenanthro-[9,10-d]imidazole-1-yl)-acetic acid (PPIA). Studies on derivatization conditions indicated that the coupling reaction proceeded rapidly and smoothly in the presence of a base catalyst in acetonitrile to give the corresponding sensitively fluorescent derivatives with an excitation maximum at {lambda} {sub ex} 260 nm and an emission maximum at {lambda} {sub em} 380 nm. The labeled derivatives exhibited high stability and were enough to be efficiently analyzed by high-performance liquid chromatography. Identification of derivatives was carried out by online post-column mass spectrometry (LC/APCI-MS/MS) and showed an intense protonated molecular ion corresponding m/z [MH]{sup +} under APCI in positive-ion mode. At the same time, the fluorescence properties of derivatives in various solvents or at different temperature were investigated. The method, in conjunction with a gradient elution, offered a baseline resolution of the common amine derivatives on a reversed-phase Eclipse XDB-C{sub 8} column. LC separation for the derivatized amines showed good reproducibility with acetonitrile-water as mobile phase. Detection limits calculated from 0.78 pmol injection, at a signal-to-noise ratio of 3, were 3.1-18.2 fmol. The mean intra- and inter-assay precision for all amine levels were <3.85% and 2.11%, respectively. Excellent linear responses were observed with coefficients of >0.9996. The established method for the determination of aliphatic amines from real wastewater and biological samples was satisfactory.

  5. Polymeric imidazolium ionic liquids as valuable stationary phases in gas chromatography: chemical synthesis and full characterization.

    Science.gov (United States)

    González-Álvarez, Jaime; Blanco-Gomis, Domingo; Arias-Abrodo, Pilar; Díaz-Llorente, Daniel; Ríos-Lombardía, Nicolás; Busto, Eduardo; Gotor-Fernández, Vicente; Gutiérrez-Álvarez, María Dolores

    2012-04-06

    Seven new functionalized polymerizable ionic liquids were chemically prepared, and later applied for the preparation of polymeric stationary phases in gas chromatography. These coated GC columns, which exhibited good thermal stabilities (240-300°C) and very high efficiencies (3120-4200 plates/m), have been characterized using the Abraham solvation parameter model. The chromatographic behavior of these polymeric IL columns has been deeply studied observing excellent selectivities in the separation of many organic substances such as alkanes, ketones, alcohols, amines or esters in mixtures of polar and non polar solvents or fragrances. Remarkably, the challenging separation of xylene isomers has been possible using a bis(trifluoromethylsulfonyl)amide based imidazolium IL coated column as a gas chromatography stationary phase.

  6. Reproducibility of retention time and peak area in comprehensive two-dimensional liquid chromatography.

    Science.gov (United States)

    Elsner, Victoria; Wulf, Volker; Wirtz, Michaela; Schmitz, Oliver J

    2015-01-01

    Comprehensive two-dimensional liquid chromatography is used to separate anionic, nonionic, and amphoteric surfactants by substance class, alkyl chain distribution, and degree of ethoxylation. A nearly orthogonal system with a hydrophilic interaction chromatography (HILIC) phase in the first and a reversed-phase material in the second dimension is applied to generate a separation with maximum peak capacity. The potential of the developed method is demonstrated by the reproducibility of retention time and peak area, which shows standard deviations less than 5 % and the analysis of real samples. An external calibration and the standard addition method were applied to determine unknown concentrations for the alkyl chain homologues of a betaine and for one ethoxylate (EO) homologue of a fatty alcohol ethoxylate in a sample mixture.

  7. Low Density Solvent-Based Dispersive Liquid-Liquid Microextraction for the Determination of Synthetic Antioxidants in Beverages by High-Performance Liquid Chromatography

    Science.gov (United States)

    Çabuk, Hasan; Köktürk, Mustafa

    2013-01-01

    A simple and efficient method was established for the determination of synthetic antioxidants in beverages by using dispersive liquid-liquid microextraction combined with high-performance liquid chromatography with ultraviolet detection. Butylated hydroxy toluene, butylated hydroxy anisole, and tert-butylhydroquinone were the antioxidants evaluated. Experimental parameters including extraction solvent, dispersive solvent, pH of sample solution, salt concentration, and extraction time were optimized. Under optimal conditions, the extraction recoveries ranged from 53 to 96%. Good linearity was observed by the square of correlation coefficients ranging from 0.9975 to 0.9997. The relative standard deviations ranged from 1.0 to 5.2% for all of the analytes. Limits of detection ranged from 0.85 to 2.73 ng mL−1. The method was successfully applied for determination of synthetic antioxidants in undiluted beverage samples with satisfactory recoveries. PMID:23853535

  8. Low density solvent-based dispersive liquid-liquid microextraction for the determination of synthetic antioxidants in beverages by high-performance liquid chromatography.

    Science.gov (United States)

    Çabuk, Hasan; Köktürk, Mustafa

    2013-01-01

    A simple and efficient method was established for the determination of synthetic antioxidants in beverages by using dispersive liquid-liquid microextraction combined with high-performance liquid chromatography with ultraviolet detection. Butylated hydroxy toluene, butylated hydroxy anisole, and tert-butylhydroquinone were the antioxidants evaluated. Experimental parameters including extraction solvent, dispersive solvent, pH of sample solution, salt concentration, and extraction time were optimized. Under optimal conditions, the extraction recoveries ranged from 53 to 96%. Good linearity was observed by the square of correlation coefficients ranging from 0.9975 to 0.9997. The relative standard deviations ranged from 1.0 to 5.2% for all of the analytes. Limits of detection ranged from 0.85 to 2.73 ng mL(-1). The method was successfully applied for determination of synthetic antioxidants in undiluted beverage samples with satisfactory recoveries.

  9. Analysis of potential migrants from plastic materials in milk by liquid chromatography-mass spectrometry with liquid-liquid extraction and low-temperature purification.

    Science.gov (United States)

    Bodai, Zsolt; Szabó, Bálint Sámuel; Novák, Márton; Hámori, Susanne; Nyiri, Zoltán; Rikker, Tamás; Eke, Zsuzsanna

    2014-10-15

    A simple and fast analytical method was developed for the determination of six UV stabilizers (Cyasorb UV-1164, Tinuvin P, Tinuvin 234, Tinuvin 326, Tinuvin 327, and Tinuvin 1577) and five antioxidants (Irgafos 168, Irganox 1010, Irganox 3114, Irganox 3790, and Irganox 565) in milk. For sample preparation liquid-liquid extraction with low-temperature purification combined with centrifugation was used to remove fats, proteins, and sugars. After the cleanup step, the sample was analyzed with high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS). External standard and matrix calibrations were tested. External calibration proved to be acceptable for Tinuvin P, Tinuvin 234, Tinuvin 326, Tinuvin 327, Irganox 3114, and Irganox 3790. The method was successfully validated with matrix calibration for all compounds. Method detection limits were between 0.25 and 10 μg/kg. Accuracies ranged from 93 to 109%, and intraday precisions were <13%.

  10. Determination of spirocyclic tetronic/tetramic acid derivatives and neonicotinoid insecticides in fruits and vegetables by liquid chromatography and mass spectrometry after dispersive liquid-liquid microextraction.

    Science.gov (United States)

    Pastor-Belda, Marta; Garrido, Isabel; Campillo, Natalia; Viñas, Pilar; Hellín, Pilar; Flores, Pilar; Fenoll, José

    2016-07-01

    Dispersive liquid-liquid microextraction was used to preconcentrate three spirocyclic tetronic/tetramic acid derivatives (spirotetramat, spiromesifen and spirodiclofen) and five neonicotinoid (thiamethoxam, chlotianidin, imidacloprid, acetamiprid and thiacloprid) insecticides previously extracted from fruit and vegetable matrices with acetonitrile. The organic enriched phase was evaporated, reconstituted in 25μL acetonitrile and analyzed by reversed-phase liquid chromatography with tandem mass spectrometry using a triple quadrupole in selected reaction monitoring mode. Enrichment factors in the 15-100 range were obtained. A matrix effect was observed, the detection limits varying between 0.025 and 0.5ngg(-1), depending on the compound and the sample matrix. The developed method was applied to the analysis of 25 samples corresponding to five different fruit and vegetable matrices. Only thiamethoxam was detected in a lemon sample at a concentration close to the quantification limit, and spiromesifen and spirotetramat at concentrations between 11.6 and 54.5ngg(-1).

  11. Analysis of recombinant Schistosoma mansoni antigen rSmp28 by on-line liquid chromatography-mass spectrometry combined with sodium dodecyl sulfate polyacrylamide gel electrophoresis

    NARCIS (Netherlands)

    Klarskov, K.; Roecklin, D.; Bouchon, B.; Sabatie, J.; Van Dorsselaer, A.; Bischoff, Rainer

    1994-01-01

    A recombinant Schistosoma mansoni antigen produced in Saccharomyces cerevisiae and purified by glutathione-Sepharose affinity chromatography was analyzed by tryptic peptide mapping using on-line reversed-phase high-performance liquid chromatography pneumatically assisted electrospray mass

  12. Gas Chromatography/Atmospheric Pressure Chemical Ionization Tandem Mass Spectrometry for Fingerprinting the Macondo Oil Spill.

    Science.gov (United States)

    Lobodin, Vladislav V; Maksimova, Ekaterina V; Rodgers, Ryan P

    2016-07-05

    We report the first application of a new mass spectrometry technique (gas chromatography combined to atmospheric pressure chemical ionization tandem mass spectrometry, GC/APCI-MS/MS) for fingerprinting a crude oil and environmental samples from the largest accidental marine oil spill in history (the Macondo oil spill, the Gulf of Mexico, 2010). The fingerprinting of the oil spill is based on a trace analysis of petroleum biomarkers (steranes, diasteranes, and pentacyclic triterpanes) naturally occurring in crude oil. GC/APCI enables soft ionization of petroleum compounds that form abundant molecular ions without (or little) fragmentation. The ability to operate the instrument simultaneously in several tandem mass spectrometry (MS/MS) modes (e.g., full scan, product ion scan, reaction monitoring) significantly improves structural information content and sensitivity of analysis. For fingerprinting the oil spill, we constructed diagrams and conducted correlation studies that measure the similarity between environmental samples and enable us to differentiate the Macondo oil spill from other sources.

  13. A sensitive gas chromatography detector based on atmospheric pressure chemical ionization by a dielectric barrier discharge.

    Science.gov (United States)

    Kirk, Ansgar T; Last, Torben; Zimmermann, Stefan

    2017-02-03

    In this work, we present a novel concept for a gas chromatography detector utilizing an atmospheric pressure chemical ionization which is initialized by a dielectric barrier discharge. In general, such a detector can be simple and low-cost, while achieving extremely good limits of detection. However, it is non-selective apart from the use of chemical dopants. Here, a demonstrator manufactured entirely from fused silica capillaries and printed circuit boards is shown. It has a size of 75×60×25mm(3) and utilizes only 2W of power in total. Unlike other known discharge detectors, which require high-purity helium, this detector can theoretically be operated using any gas able to form stable ion species. Here, purified air is used. With this setup, limits of detection in the low parts-per-billion range have been obtained for acetone.

  14. Determination of three estrogens and bisphenol A by functional ionic liquid dispersive liquid-phase microextraction coupled with ultra-high performance liquid chromatography and ultraviolet detection.

    Science.gov (United States)

    Jiang, Yuehuang; Tang, Tingting; Cao, Zhen; Shi, Guoyue; Zhou, Tianshu

    2015-06-01

    A hydroxyl-functionalized ionic liquid, 1-hydroxyethyl-3-methylimidazolium bis(trifluoromethanesulfonyl)imide, was employed in an improved dispersive liquid-phase microextraction method coupled with ultra high performance liquid chromatography for the enrichment and determination of three estrogens and bisphenol A in environmental water samples. The introduced hydroxyl group acted as the H-bond acceptor that dispersed the ionic liquid effectively in the aqueous phase without dispersive solvent or external force. Fourier transform infrared spectroscopy indicated that the hydroxyl group of the cation of the ionic liquid enhanced the combination of extractant and analytes through the formation of hydrogen bonds. The improvement of the extraction efficiency compared with that with the use of alkyl ionic liquid was proved by a comparison study. The main parameters including volume of extractant, temperature, pH, and extraction time were investigated. The calibration curves were linear in the range of 5.0-1000 μg/L for estrone, estradiol, and bisphenol A, and 10.0-1000 μg/L for estriol. The detection limits were in the range of 1.7-3.4 μg/L. The extraction efficiency was evaluated by enrichment factor that were between 85 and 129. The proposed method was proved to be simple, low cost, and environmentally friendly for the determination of the four endocrine disruptors in environmental water samples.

  15. Study of surface-bonded dicationic ionic liquids as stationary phases for hydrophilic interaction chromatography.

    Science.gov (United States)

    Qiao, Lizhen; Li, Hua; Shan, Yuanhong; Wang, Shuangyuan; Shi, Xianzhe; Lu, Xin; Xu, Guowang

    2014-02-21

    In the present study, several geminal dicationic ionic liquids based on 1,4-bis(3-allylimidazolium)butane and 1,8-bis(3-allylimidazolium)octane in combination with different anions bromide and bis(trifluoromethanesulphonyl)imide were prepared and then bonded to the surface of 3-mercaptopropyl modified silica materials through the "thiol-ene" click chemistry as stationary phases for hydrophilic interaction chromatography (HILIC). Compared with their monocationic analogues, the dicationic ionic liquids stationary phases presented effective retention and good selectivity for typical hydrophilic compounds under HILIC mode with the column efficiency as high as 130,000 plates/m. Moreover, the influence of different alkyl chain spacer between dications and combined anions on the retention behavior and selectivity of the dicationic ionic liquids stationary phases under HILIC mode was displayed. The results indicated that the longer linkage chain would decrease the hydrophilicity and retention on the dicationic ionic liquid stationary phase, and while differently combined anions had no difference due to the exchangeability under the common HILIC mobile phase with buffer salt. Finally, the retention mechanism was investigated by evaluating the effect of chromatographic factors on retention, including the water content in the mobile phase, the mobile phase pH and buffer salt concentration. The results showed that the dicationic ionic liquids stationary phases presented a mixed-mode retention behavior with HILIC mechanism and anion exchange.

  16. Characterization of rhamnolipids by liquid chromatography/mass spectrometry after solid-phase extraction.

    Science.gov (United States)

    Behrens, Beate; Engelen, Jeannine; Tiso, Till; Blank, Lars Mathias; Hayen, Heiko

    2016-04-01

    Rhamnolipids are surface-active agents with a broad application potential that are produced in complex mixtures by bacteria of the genus Pseudomonas. Analysis from fermentation broth is often characterized by laborious sample preparation and requires hyphenated analytical techniques like liquid chromatography coupled to mass spectrometry (LC-MS) to obtain detailed information about sample composition. In this study, an analytical procedure based on chromatographic method development and characterization of rhamnolipid sample material by LC-MS as well as a comparison of two sample preparation methods, i.e., liquid-liquid extraction and solid-phase extraction, is presented. Efficient separation was achieved under reversed-phase conditions using a mixed propylphenyl and octadecylsilyl-modified silica gel stationary phase. LC-MS/MS analysis of a supernatant from Pseudomonas putida strain KT2440 pVLT33_rhlABC grown on glucose as sole carbon source and purified by solid-phase extraction revealed a total of 20 congeners of di-rhamnolipids, mono-rhamnolipids, and their biosynthetic precursors 3-(3-hydroxyalkanoyloxy)alkanoic acids (HAAs) with different carbon chain lengths from C8 to C14, including three rhamnolipids with uncommon C9 and C11 fatty acid residues. LC-MS and the orcinol assay were used to evaluate the developed solid-phase extraction method in comparison with the established liquid-liquid extraction. Solid-phase extraction exhibited higher yields and reproducibility as well as lower experimental effort.

  17. [Diagnosis of anaerobic infection of the pleural fluid using gas-liquid chromatography].

    Science.gov (United States)

    Alvarez, M; Rojo, P; Latorre, M; Herrero, O; Arriaga, I; Merino, J M; Cisterna, R

    1993-02-01

    An assessment of the efficacy of the detection of volatile and non-volatile fatty acids that are produced by microorganisms aimed at the possible diagnosis of pleural empyema. 106 pleural fluids were examined by gas-liquid chromatography in contrast to conventional aerobic and anaerobic cultures. The sample previously prepared (1 microliter) was injected in an Hewlett-Packard 5890 chromatograph, that was equipped with a fused silica capillary column and a flame ionization detector. Growth of aerobic or anaerobic microorganisms was obtained in 13 (12.3%) of the samples, and volatile or non-volatile fatty acids were detected in all of them (sensitivity = 1). No growth was obtained in the 93 samples, but volatile or non-volatile fatty acids were detected in 64 (68.8%) of them (specificity = 0.31). A positive predictive value of 0.17 and a negative predictive value of 1 were obtained. Growth of anaerobic microorganisms was obtained in 9 samples (8.5%) and volatile fatty acids were detected in all of them (sensitivity = 1). Anaerobic microorganisms did not grow in 97 samples, however volatile fatty acids were detected in 2 (2.1%) of them. A positive predictive value of 0.82 and a negative of 1 were obtained. Referring to pleural fluid samples, the detection of volatile and non-volatile fatty acids by gas-liquid chromatography is a highly sensitive method, that may be used to quickly reject negative samples in about 30 mins. Furthermore, when anaerobic microorganisms exist, the high specificity of gas-liquid chromatography will make it possible to confirm their presence in the sample, mainly if there is a clinical suspect of anaerobic infection. Thus, the utilization of this sensitive method may also change the therapeutic behaviour.

  18. Integration of electrochemistry with ultra-performance liquid chromatography/mass spectrometry.

    Science.gov (United States)

    Cai, Yi; Zheng, Qiuling; Liu, Yong; Helmy, Roy; Loo, Joseph A; Chen, Hao

    2015-01-01

    This study presents the development of ultra-performance liquid chromatography (UPLC) mass spectrometry (MS) combined with electrochemistry (EC) for the first time and its application for the structural analysis of proteins/peptides that contain disulfide bonds. In our approach, a protein/peptide mixture sample undergoes a fast UPLC separation and subsequent electrochemical reduction in an electrochemical flow cell followed by online MS and tandem mass spectrometry (MS/MS) analyses. The electrochemical cell is coupled to the mass spectrometer using our recently developed desorption electrospray ionization (DESI) interface. Using this UPLC/EC/DESI-MS method, peptides that contain disulfide bonds can be differentiated from those without disulfide bonds, as the former are electroactive and reducible. MS/MS analysis of the disulfide-reduced peptide ions provides increased information on the sequence and disulfide-linkage pattern. In a reactive DESI- MS detection experiment in which a supercharging reagent was used to dope the DESI spray solvent, increased charging was obtained for the UPLC-separated proteins. Strikingly, upon online electrolytic reduction, supercharged proteins (e.g., α-lactalbumin) showed even higher charging, which will be useful in top- down protein structure MS analysis as increased charges are known to promote protein ion dissociation. Also, the separation speed and sensitivity are enhanced by approximately 1(~)2 orders of magnitude by using UPLC for the liquid chromatography (LC)/EC/MS platform, in comparison to the previously used high- performance liquid chromatography (HPLC). This UPLC/EC/DESI-MS method combines the power of fast UPLC separation, fast electrochemical conversion, and online MS structural analysis for a potentially valuable tool for proteomics research and bioanalysis.

  19. Detecting trace components in liquid chromatography/mass spectrometry data sets with two-dimensional wavelets

    Science.gov (United States)

    Compton, Duane C.; Snapp, Robert R.

    2007-09-01

    TWiGS (two-dimensional wavelet transform with generalized cross validation and soft thresholding) is a novel algorithm for denoising liquid chromatography-mass spectrometry (LC-MS) data for use in "shot-gun" proteomics. Proteomics, the study of all proteins in an organism, is an emerging field that has already proven successful for drug and disease discovery in humans. There are a number of constraints that limit the effectiveness of liquid chromatography-mass spectrometry (LC-MS) for shot-gun proteomics, where the chemical signals are typically weak, and data sets are computationally large. Most algorithms suffer greatly from a researcher driven bias, making the results irreproducible and unusable by other laboratories. We thus introduce a new algorithm, TWiGS, that removes electrical (additive white) and chemical noise from LC-MS data sets. TWiGS is developed to be a true two-dimensional algorithm, which operates in the time-frequency domain, and minimizes the amount of researcher bias. It is based on the traditional discrete wavelet transform (DWT), which allows for fast and reproducible analysis. The separable two-dimensional DWT decomposition is paired with generalized cross validation and soft thresholding. The Haar, Coiflet-6, Daubechie-4 and the number of decomposition levels are determined based on observed experimental results. Using a synthetic LC-MS data model, TWiGS accurately retains key characteristics of the peaks in both the time and m/z domain, and can detect peaks from noise of the same intensity. TWiGS is applied to angiotensin I and II samples run on a LC-ESI-TOF-MS (liquid-chromatography-electrospray-ionization) to demonstrate its utility for the detection of low-lying peaks obscured by noise.

  20. Analysis of estrogens and androgens in postmenopausal serum and plasma by liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Wang, Qingqing; Bottalico, Lisa; Mesaros, Clementina; Blair, Ian A

    2015-07-01

    Liquid chromatography-selected reaction monitoring/mass spectrometry-based methodology has evolved to the point where accurate analyses of trace levels of estrogens and androgens in postmenopausal serum and plasma can be accomplished with high precision and accuracy. A suite of derivatization procedures has been developed, which together with modern mass spectrometry instrumentation provide investigators with robust and sensitive methodology. Pre-ionized derivatives are proving to be useful as they are not subject to suppression of the electrospray signal. Postmenopausal women with elevated plasma or serum estrogens are thought to be at increased risk for breast and endometrial cancer. Therefore, significant advances in risk assessment should be possible now that reliable methodology is available. It is also possible to conduct analyses of multiple estrogens in plasma or serum. Laboratories that are currently employing liquid chromatography/mass spectrometry methodology can now readily implement this strategy. This will help conserve important plasma and serum samples available in Biobanks, as it will be possible to conduct high sensitivity analyses using low initial sample volumes. Reported levels of both conjugated and non-conjugated estrogen metabolites are close to the limits of sensitivity of many assays to date, urging caution in the interpretation of these low values. The analysis of serum androgen precursors in postmenopausal women has not been conducted routinely in the past using liquid chromatography/mass spectrometry methodology. Integration of serum androgen levels into the panel of metabolites analyzed could provide additional information for assessing cancer risk and should be included in the future.

  1. Salting-out homogenous extraction followed by ionic liquid/ionic liquid liquid-liquid micro-extraction for determination of sulfonamides in blood by high performance liquid chromatography.

    Science.gov (United States)

    Liu, Zhongling; Yu, Wei; Zhang, Hanqi; Gu, Fanbin; Jin, Xiangqun

    2016-12-01

    Salting-out homogenous extraction followed by ionic liquid/ionic liquid dispersive liquid-liquid micro-extraction system was developed and applied to the extraction of sulfonamides in blood. High-performance liquid chromatography was applied to the determination of the analytes. The blood sample was centrifuged to obtain the serum. After the proteins in the serum were removed in the presence of acetonitrile, ionic liquid 1-butyl-3-methylimidazolium tetrafluoroborate, dipotassium hydrogen phosphate, ionic liquid 1-Hexyl-3-methylimidazolium hexafluorophosphate were added into the resulting solution. After the resulting mixture was ultrasonically shaken and centrifuged, the precipitate was separated. The acetonitrile was added in the precipitate and the analytes were extracted into the acetonitrile phase. The parameters affecting the extraction efficiency, such as volume of ionic liquid, amount of dipotassium hydrogen phosphate, volume of dispersant, extraction time and temperature were investigated. The limits of detection of sulfamethizole (STZ), sulfachlorpyridazine (SCP), sulfamethoxazole (SMX) and Sulfisoxazole (SSZ) were 4.78, 3.99, 5.21 and 3.77μgL(-1), respectively. When the present method was applied to the analysis of real blood samples, the recoveries of analytes ranged from 90.0% to 113.0% and relative standard deviations were lower than 7.2%.

  2. Combining Laser Ablation/Liquid Phase Collection Surface Sampling and High-Performance Liquid Chromatography Electrospray Ionization Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Ovchinnikova, Olga S [ORNL; Kertesz, Vilmos [ORNL; Van Berkel, Gary J [ORNL

    2011-01-01

    This paper describes the coupling of ambient pressure transmission geometry laser ablation with a liquid phase sample collection method for surface sampling and ionization with subsequent mass spectral analysis. A commercially available autosampler was adapted to produce a liquid droplet at the end of the syringe injection needle while in close proximity to the surface to collect the sample plume produced by laser ablation. The sample collection was followed by either flow injection or a high performance liquid chromatography (HPLC) separation of the extracted components and detection with electrospray ionization mass spectrometry (ESI-MS). To illustrate the analytical utility of this coupling, thin films of a commercial ink sample containing rhodamine 6G and of mixed isobaric rhodamine B and 6G dyes on glass microscope slides were analyzed. The flow injection and HPLC/ESI-MS analysis revealed successful laser ablation, capture and, with HPLC, the separation of the two compounds. The ablated circular area was about 70 m in diameter for these experiments. The spatial sampling resolution afforded by the laser ablation, as well as the ability to use sample processing methods like HPLC between the sample collection and ionization steps, makes this combined surface sampling/ionization technique a highly versatile analytical tool.

  3. Pressurized nano-liquid-junction interface for coupling capillary electrochromatography and nano-liquid chromatography with mass spectrometry.

    Science.gov (United States)

    D'Orazio, Giovanni; Fanali, Salvatore

    2013-11-22

    A new nano-liquid-junction interface for coupling both capillary electrochromatography (CEC) or nano-liquid chromatography (nano-LC) with mass spectrometry (MS) was studied. The interface was a small T piece of polymeric material where capillary column and tip capillary were positioned at 180° while the third exit (at 90°) was occupied by a capillary delivering a liquid-assisting spray ionization for CEC experiments or by the electrode for the high voltage spray for nano-LC. Experiments were carried out analyzing mixtures of some organophosphorus pesticides (OPPs) or anti-inflammatory and related acidic drugs with MS detection in positive or negative ion mode, respectively. Analyzed OPPs compounds were baseline resolved utilizing the novel interface in both nano-LC and CEC obtaining good sensitivity and repeatability. For CEC-MS, the limits of detection ranged between 0.03 and 6.80 μg/mL and the intra-day repeatability was RSD interface was easy to handle and good reproducibility, between 2.5 and 3.5% for the retention time and interface was installed by two different analysts. Furthermore, it could be used for both CEC and nano-LC.

  4. Determination of tocopherols and tocotrienols in cereals by pressurized liquid extraction-liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Bustamante-Rangel, M; Delgado-Zamarreño, M M; Sánchez-Pérez, A; Carabias-Martínez, R

    2007-03-28

    A rapid analytical method including pressurized liquid extraction (PLE) and liquid chromatography-electrospray ionisation-mass spectrometry (LC-ESI-MS) has been developed for the determination of tocopherols and tocotrienols in cereals. The pressurized liquid extraction parameters were optimized in order to maximize the extraction efficiency. The use of methanol as extraction solvent at a temperature of 50 degrees C and a pressure of 110 bar, using one cycle of extraction with a static time of 5 min, provided the best results. A good LC separation was achieved using a C(18) column and a solution of 6.0 mM ammonia in methanol/water (97:3, v/v) as the mobile phase at a flow rate of 0.2 mL min(-1). MS coupling with an ESI interface in the negative ion mode was used as the detection technique. In the present work, it is shown that the addition of a base to the mobile phase is required to enhance the ionization of tocopherols and tocotrienols in negative ion mode electrospray ionization. The applicability of the method to cereal samples was confirmed. The reproducibility of the procedure was good, with relative standard deviations in the 6-10% range. The recoveries of added tocopherols from cereal samples ranged from 91 to 109%.

  5. Development of an enhanced separation of erythromycin and its related substances by liquid chromatography.

    Science.gov (United States)

    Deubel, A; Holzgrabe, U

    2007-01-17

    A new HPLC-UV method for the determination of the impurity profile of erythromycin is developed. In contrast to the liquid chromatography described in the European Pharmacopoeia the analysis could be performed at a temperature of 25 degrees C. Erythromycin samples were analysed on an endcapped RP phase with cyanopropyl groups on the surface using gradient elution with 32 mM potassium phosphate buffer pH 8.0 and acetonitrile/methanol (75:25). The aforementioned method shows clear improvements compared to the actual method of the European Pharmacopoeia, which is less selective and sensitive.

  6. On-line radiochemical assay for monoamine oxidase utilizing high-performance liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Nissinen, E.; Linko-Loeppoenen SMae; Maennistoe P4

    1984-12-01

    A fast and sensitive assay for the determination of monoamine oxidase activity was developed. The method is based on the separation and quantitation of /sup 14/C-labeled assay products by high-performance liquid chromatography, which is interfaced directly into a flow-through radioactivity detector. This allows on-line quantitation of the radioactive compounds with picomole sensitivity. The method makes possible the complete separation and detection of the deaminated products of monoamine oxidase A and B substrates benzylamine and 5-hydroxytryptamine, respectively. This assay has been applied to the measurement of monoamine oxidase A and B activities in rat brain.

  7. Determination of enantiomeric impurity of etomidate by high performance liquid chromatography

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    Objective To determine enantiomeric impurity of etomidate using high performance liquid chromatography. Methods (R)-etomidate and (S)-etomidate were separated on a CHIRALPAK AD-H column. The mobile phase consisted of 20∶80(v/v) isopropanol-n-hexane. The flow rate of the mobile phase was 0.5mL/min. The detected wavelength was 242nm. Results (R)-etomidate and (S)-etomidate could be separated completely under these conditions. The precision of (R)-etomidate was 1.57% (n=3). The limit of detection of (R)-etomid...

  8. DETERMINATION OF GAMMA - AMINOBUTYRIC ACID BY HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY

    Directory of Open Access Journals (Sweden)

    D. Qujeq

    1998-08-01

    Full Text Available Gamma-aminobutyric acid is the main inhibitory amino acid neurotransmitter in several areas of the brain. Measurement of gamma-aminobutyric acid in the brain will help elucidate its metabolic rote and diagnostic value. The liquid chromatography (LC system consisted of a delivery pump. Male rats (150-250g were used in this study. The brain was rapidly removed from decapitated animals. Trie chromatograms showed satisfactory resolution and symmetrical peak shapes, both with the standard and tissue extracts. the retention lime was 4.60 min. it was constant in repeated analyses and exactly the same for the standard and tissue samples.

  9. Anomalous properties of flavonoids in reversed phase high performance liquid chromatography

    Science.gov (United States)

    Zenkevich, I. G.; Gushchina, S. V.

    2011-09-01

    It is shown through reversed phase high performance liquid chromatography that a characteristic feature of such abundant natural flavonoids as flavon-3-ols is an anomalously strong antibate dependence of their retention indices ( RI) on the organic solvent concentration ( C) in the eluent, dRI/ dC < 0. In order to interpret this anomaly, the specific optical rotation values [α]{D/20} of natural (+)-(2 R,3 R)-dihydroquercetin in different solvents are compared, confirming the reverse formation of hydrated flavonoids in aqueous solutions.

  10. Study of Saiga Horn Using High-Performance Liquid Chromatography with Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Kateřina Mikulíková

    2012-01-01

    Full Text Available The saiga horns have been investigated the using of modern analytic methods. High-performance liquid chromatography (HPLC with mass-spectrometric (MS and MS/MS detection and polyacrylamide gel electrophoresis (PAGE were used. It could be concluded that basic proteins of the saiga horns are keratins and collagen. The basic representation protein in all samples is keratin type I microfibrillar (from sheep, keratin type II microfibrillar (from sheep, collagen type I (α1 (from bovine and collagen type I (α2 (from bovine. Free amino acids we determined in all samples are nontreated by enzyme.

  11. Determination of cortisol and cortisone in urine using high-performance liquid chromatography with UV detection.

    Science.gov (United States)

    Jenner, D A; Richards, J

    1985-01-01

    The application of reversed-phase gradient high-performance liquid chromatography with UV detection to the determination of cortisol and cortisone in 24-h urine samples is described. The method employs Sep-pak C18 cartridges for the part-purification and concentration of the corticosteroids, with sample enrichment at the head of an HPLC pre-column and separation using water/acetonitrile gradient. The internal standard is 6alpha-methylprednisolone. Measurement of both cortisone and cortisol provides further information on adrenocortical function. 24-hour excretion rate data from normal subjects are reported.

  12. Determination of rhoifolin and daidzin in human plasma by high-performance liquid chromatography.

    Science.gov (United States)

    Ishii, K; Urano, S; Furuta, T; Kasuya, Y

    1994-05-13

    A method for determining flavonoids in human plasma is presented for application to pharmacokinetic studies of two flavonoids, rhoifolin and daidzin. Isocratic reversed-phase high-performance liquid chromatography (HPLC) was used with genistin as an internal standard and solid-phase extraction using a Sep-Pak C18 cartridge. The mobile phases were acetonitrile-0.1 M ammonium acetate solution (20:80, v/v) for rhoifolin and methanol-0.1 M ammonium acetate solution (33:67, v/v) for daidzin. The detection limits on-column were 2 ng for rhoifolin and 0.5 ng for daidzin.

  13. Tools to discover anionic and nonionic polyfluorinated alkyl surfactants by liquid chromatography electrospray ionisation mass spectrometry

    DEFF Research Database (Denmark)

    Trier, Xenia; Granby, Kit; Christensen, Jan H.

    2011-01-01

    A tiered approach is proposed for the discovery of unknown anionic and nonionic polyfluorinated alkyl surfactants (PFASs) by reversed phase ultra high performance liquid chromatography (UHPLC) – negative electrospray ionisation – quadrupole time of flight mass spectrometry (UHPLC......–ESI−–QTOF–MS). The chromatographic separation, ionisation and detection of PFASs mixtures, was achieved at high pH (pH=9.7) with NH4OH as additive. To distinguish PFASs from other chemicals we used the characteristic negative mass defects of PFASs, their specific losses of 20Da (HF) and the presence of series of chromatographic...

  14. Quantitative analysis of forskolin in Coleus forskohlii (Lamiaceae) by reversed-phase liquid chromatography.

    Science.gov (United States)

    Schaneberg, Brian T; Khan, Ikhlas A

    2003-01-01

    A rapid method was developed for the evaluation of forskolin in Coleus forskohlii Briq. (Lamiaceae). Forskolin was quantitated in the root and stem of dried C. forskohlii and in 17 market products by reversed-phase liquid chromatography (LC) with a photodiode array detector at 210 nm. The temperature was held constant at 30 degrees C, and the retention time of forskolin was approximately 6.8 min. The samples were extracted with acetonitrile by sonication. The precision of the method was confirmed by a standard deviation forskohlii plant material and in market products claiming to contain C. forskohlii.

  15. Separation analysis of some food constituents and Durification of enzyme in food by liquid chromatography

    OpenAIRE

    大槻, 耕三; 松尾, 亜希子; 尾原, 宏美; 宮田, 真理子; 村西, 映美; 佐藤, 健司; 中村, 孝志; KOZO, OHTSUKI; AKIKO, MATSUO; HIROMI, OBARA; MARIKO, MIYATA; TERUMI, MURANISHI; KENJI, SATO; YASUSHI, NAKAMURA; 京都府立大学人間環境学部食保健学科食品科学研究室

    2004-01-01

    Liquid chromatography and HPLC were successfully used for the determination of some food constituents and the purification of an enzyme in food. Free and total amino acids, water extracts and 6N-HC1 vapor hydrolysates in foods were analyzed in an ion-exchange HPLC-amino acid analyzer with lithium citrate buffers and post-column fluorimetric detection with o-phthalaldehyde - N-acetyl-L-Cysteine reagent. Tryptophan content in green tea, Mat-Cha, was also analyzed in an HPLC with fluorimetric de...

  16. Stationary phase optimized selectivity liquid chromatography: Basic possibilities of serially connected columns using the "PRISMA" principle.

    Science.gov (United States)

    Nyiredy, Sz; Szucs, Zoltán; Szepesy, L

    2007-07-20

    A new procedure (stationary phase optimized selectivity liquid chromatography: SOS-LC) is described for the optimization of the HPLC stationary phase, using serially connected columns and the principle of the "PRISMA" model. The retention factors (k) of the analytes were determined on three different stationary phases. By use of these data the k values were predicted applying theoretically combined stationary phases. These predictions resulted in numerous intermediate theoretical separations from among which only the optimal one was assembled and tested. The overall selectivity of this separation was better than that of any individual base stationary phase. SOS-LC is independent of the mechanism and the scale of separation.

  17. Impurity profiling and in-process testing of drugs for injection by fast liquid chromatography

    Institute of Scientific and Technical Information of China (English)

    Marie-Josee Rocheleau; Elaine Larouche; Cristina Salamu; Mihaela Curca

    2012-01-01

    Liquid chromatography (LC) is considered by many as a mature technique. Nonetheless, LC technology continues to evolve driven by the need for high-throughput and high-resolution analyses. Over the past several years, small particle size packing materials have been introduced by several column manufacturers to enable fast and efficient LC separations. Several examples of pharmaceutical analyses, including impurity profiling of taxanes and atracurium besylate, in-process testing of peptides in injectable dosage form, using sub-2 um column technology are presented in this paper, demonstrating some of the capabilities and limitations of the technology.

  18. Detection of cheese whey and caseinomacropeptide in fermented milk beverages using high performance liquid chromatography

    OpenAIRE

    E.H.P. Andrade; M.R. Souza; Fonseca,L.M.; C.F.A.M. Penna; M.M.O.P. Cerqueira; T. Roza; Seridan,B.; M.F.S. Resende; Pinto, F. A.; C.N.B.C. Villanoeva; Leite,M.O.

    2014-01-01

    Cheese whey level and caseinomacropeptide (CMP) index of fermented milk beverages added with four levels of cheese whey (0, 10, 20, and 40%) and stored at 8-10oC for 0, 7, 14 and 21 days were determined by high performance liquid chromatography-gel filtration (HPLC-GF). Additionally, the interference of the starter culture and the storage time on the detection of cheese whey and CMP were investigated. Refrigerated storage up to 21 days did not affect (P>0.05) cheese whey and CMP amounts in mi...

  19. Characterization of oil sands process-affected waters by liquid chromatography orbitrap mass spectrometry.

    Science.gov (United States)

    Pereira, Alberto S; Bhattacharjee, Subir; Martin, Jonathan W

    2013-05-21

    Recovery of bitumen from oil sands in northern Alberta, Canada, occurs by surface mining or in situ thermal recovery, and both methods produce toxic oil sands process-affected water (OSPW). A new characterization strategy for surface mining OSPW (sm-OSPW) and in situ OSPW (is-OSPW) was achieved by combining liquid chromatography with orbitrap mass spectrometry (MS). In electrospray positive and negative ionization modes (ESI(+)/ESI(-)), mass spectral data were acquired with high resolving power (RP > 100,000-190,000) and mass accuracy (method should be further applied to environmental forensic analysis of water in the region.

  20. Analyzing Activities of Lytic Polysaccharide Monooxygenases by Liquid Chromatography and Mass Spectrometry

    DEFF Research Database (Denmark)

    Westereng, Bjørge; Arntzen, Magnus Ø.; Wittrup Agger, Jane

    2017-01-01

    , whereas C4 oxidation leads to products that are inherently labileat high and low pH and that exist in a keto-gemdiol equilibrium that is strongly shifted toward the gemdiolin aqueous solutions. Partial degradation of C4-oxidized products leads to the formation of native products,which could explain why...... necessitate the use of sensitive product detection methods, which limits the analytical possibilities considerably. Modern liquid chromatography and mass spectrometry have become essential tools for evaluating LPMO activity, and this chapter provides an overview of available methods together with a few novel...