WorldWideScience

Sample records for liquid chromatograph tandem

  1. Liquid chromatographic-tandem mass spectrometric assay for ...

    African Journals Online (AJOL)

    Methods: Blood and urine samples were obtained from healthy volunteers who admitted to not being on any medications. The investigated analytes were chromatographically separated on a C18 column (Luna®-PFP 100Å column, 50 mm × 2.0 mm i.d., 3.0 μm) with the aid of a mobile phase containing A; acetonitrile (ACN) ...

  2. Liquid chromatographic-tandem mass spectrometric determination of selected sulphonamides in milk

    NARCIS (Netherlands)

    Rhijn, van J.A.; Lasaroms, J.J.P.; Berendsen, B.J.A.; Brinkman, U.A.Th.

    2002-01-01

    Liquid chromatography–tandem mass spectrometry is used for the quantitative analysis of selected sulphonamides in milk. Ultrafiltration is the only sample pre-treatment technique which is required. Consequently, sample throughput is much higher than with conventional procedures, and analyte

  3. High-performance Liquid Chromatographic Ultraviolet Detection of Nilotinib in Human Plasma from Patients with Chronic Myelogenous Leukemia, and Comparison with Liquid Chromatography-Tandem Mass Spectrometry.

    Science.gov (United States)

    Nakahara, Ryosuke; Satho, Yuhki; Itoh, Hiroki

    2016-11-01

    A method for determining nilotinib concentration in human plasma is proposed using high-performance liquid chromatography and ultraviolet detection. Nilotinib and the internal standard dasatinib were separated using a mobile phase of 0.5% Na 2 PO 4 H 2 O (pH 2.5)-acetonitrile-methanol (55:25:20, v/v/v) on a Capcell Pak C18 MG II column (250 × 4.6 mm) at a flow rate of 1.0 ml/min, and ultraviolet measurement at 250 nm. The calibration curve exhibited linearity over the nilotinib concentration range of 50-2,500 ng/ml at 250 nm, with relative standard deviations (n = 5) of 7.1%, 2.5%, and 2.9% for 250, 1,500, and 2,500 ng/ml, respectively. The detection limit for nilotinib was 5 ng/ml due to three blank determinations (ρ = 3). This method was successfully applied to assaying nilotinib in human plasma samples from patients with chronic myelogenous leukemia. In addition, we compared the results with those measured by liquid chromatography-tandem mass spectrometry (LC-MS/MS) at BML, Inc. (a commercial laboratory). A strong correlation was observed between the nilotinib concentrations measured by our high-performance liquid chromatographic method and those obtained by LC/MS-MS (r 2 = 0.988, P < 0.01). © 2016 Wiley Periodicals, Inc.

  4. Dual liquid and gas chromatograph system

    Science.gov (United States)

    Gay, D.D.

    A chromatographic system is described that utilizes one detection system for gas chromatographic and micro-liquid chromatographic determinations. The detection system is a direct-current, atmospheric-pressure, helium plasma emission spectrometer. The detector utilizes a nontransparent plasma source unit which contains the plasma region and two side-arms which receive effluents from the micro-liquid chromatograph and the gas chromatograph. The dual nature of this chromatographic system offers: (1) extreme flexibility in the samples to be examined; (2) extreme low sensitivity; (3) element selectivity; (4) long-term stability; (5) direct correlation of data from the liquid and gas samples; (6) simpler operation than with individual liquid and gas chromatographs, each with different detection systems; and (7) cheaper than a commercial liquid chromatograph and a gas chromatograph.

  5. Liquid chromatographic/electrospray ionization tandem mass spectrometric study of polyphenolic composition of four cultivars of Fragaria vesca L. berries and their comparative evaluation.

    Science.gov (United States)

    Del Bubba, Massimo; Checchini, Leonardo; Chiuminatto, Ugo; Doumett, Saer; Fibbi, Donatella; Giordani, Edgardo

    2012-09-01

    High-performance liquid chromatography coupled with ion spray mass spectrometry in the tandem mode with both negative and positive ionization was used for investigating a variety of polyphenolic compounds in four genotypes of Fragaria vesca berries. About 60 phenolic compounds belonging to the compound classes of phenolic acids, ellagitannins, ellagic acid derivatives, flavonols, monomeric and oligomeric flavanols, dihydrochalcones and anthocyanins were reported, providing for the first time a quite complete picture of polyphenolic composition of F. vesca berries. Some of the polyphenols herein investigated, such as a tris-galloyl-hexahydroxydiphenoyl-hexose, two castalagin/vescalagin-like isomers and peonidin-malonylglucoside, were described for the first time. Principal component analysis applied on original HPLC-MS/MS data, acquired in multiple reaction monitoring mode, successfully discriminated the four investigated cultivars on the basis of their polyphenolic composition, highlighting the fundamental role of mass spectrometry for food characterization. Copyright © 2012 John Wiley & Sons, Ltd.

  6. Quantification of rifampicin in human plasma and cerebrospinal fluid by a highly sensitive and rapid liquid chromatographic-tandem mass spectrometric method.

    Science.gov (United States)

    Srivastava, Abhishek; Waterhouse, David; Ardrey, Alison; Ward, Stephen A

    2012-11-01

    A highly sensitive and rapid liquid chromatography tandem mass spectrometry (LC-MS/MS) method has been developed to measure the levels of the antitubercular drug rifampicin (RIF) in human plasma and cerebrospinal fluid (CSF). The analyte and internal standard (IS) were isolated from plasma and CSF by a simple organic solvent based precipitation of proteins followed by centrifugation. Detection was carried out by electrospray positive ionization mass spectrometry in the multiple-reaction monitoring (MRM) mode. The assay was linear in the concentration range 25-6400 ng/mL with intra- and inter-day precision of <7% and <8%, respectively. The validated method was applied to the study of RIF pharmacokinetics in human CSF and plasma over 25 h period after a 10 mg/kg oral dose. Copyright © 2012 Elsevier B.V. All rights reserved.

  7. Determination of multiresidue analysis of β-agonists in muscle and viscera using liquid chromatograph/tandem mass spectrometry with Quick, Easy, Cheap, Effective, Rugged, and Safe methodologies

    Directory of Open Access Journals (Sweden)

    Yen-Ping Lin

    2017-04-01

    Full Text Available The official analytical method of the Taiwan Food and Drug Administration, Ministry of Health and Welfare for testing for veterinary drug residues in foods is the multiresidue analysis of β-agonists. Samples are pretreated through liquid–liquid extraction and solid-phase extraction. This method is time consuming and requires the intensive use of solvents. To improve analytical efficiency and reduce costs, our study incorporated QuEChERS (Quick, Easy, Cheap, Effective, Rugged, and Safe techniques to establish a new method of multiresidue analysis of β-agonists in animal muscle and viscera. The pretreatment time was shortened and solvent usage was minimized. The modified analysis was conducted using liquid chromatography/tandem mass spectrometry (LC–MS/MS and quantification was performed using multiple reaction monitoring. The results demonstrated that the correlation coefficients of the tissue calibration curve were higher than 0.99 and the limit of quantification (LOQ was 1 ppb. The average recoveries in spiked samples varied from 70% to 120%, and the relative difference between duplicated analysis results was lower than 10%. On the basis of the results, the proposed method was concluded to be an appropriate procedure for determining the presence of β-agonists, and demonstrated the advantages of high recovery rates in spiked samples, high precision, reduced analysis time and solvent usage, and lower costs.

  8. Automated multi-plug filtration cleanup for liquid chromatographic-tandem mass spectrometric pesticide multi-residue analysis in representative crop commodities.

    Science.gov (United States)

    Qin, Yuhong; Zhang, Jingru; Zhang, Yuan; Li, Fangbing; Han, Yongtao; Zou, Nan; Xu, Haowei; Qian, Meiyuan; Pan, Canping

    2016-09-02

    An automated multi-plug filtration cleanup (m-PFC) method on modified QuEChERS (quick, easy, cheap, effective, rugged, and safe) extracts was developed. The automatic device was aimed to reduce labor-consuming manual operation workload in the cleanup steps. It could control the volume and the speed of pulling and pushing cycles accurately. In this work, m-PFC was based on multi-walled carbon nanotubes (MWCNTs) mixed with other sorbents and anhydrous magnesium sulfate (MgSO4) in a packed tip for analysis of pesticide multi-residues in crop commodities followed by liquid chromatography with tandem mass spectrometric (LC-MS/MS) detection. It was validated by analyzing 25 pesticides in six representative matrices spiked at two concentration levels of 10 and 100μg/kg. Salts, sorbents, m-PFC procedure, automated pulling and pushing volume, automated pulling speed, and pushing speed for each matrix were optimized. After optimization, two general automated m-PFC methods were introduced to relatively simple (apple, citrus fruit, peanut) and relatively complex (spinach, leek, green tea) matrices. Spike recoveries were within 83 and 108% and 1-14% RSD for most analytes in the tested matrices. Matrix-matched calibrations were performed with the coefficients of determination >0.997 between concentration levels of 10 and 1000μg/kg. The developed method was successfully applied to the determination of pesticide residues in market samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Development and validation of ultra-performance liquid chromatographic method with tandem mass spectrometry for determination of lenalidomide in rabbit and human plasma

    Directory of Open Access Journals (Sweden)

    Iqbal Muzaffar

    2013-01-01

    Full Text Available Abstract Background Lenalidomide (LND is a potent novel thalidomide analog which demonstrated remarkable clinical activity in treatment of multiple myeloma disease via a multiple-pathways mechanism. Validated sensitive method with high throughput is required for the determination of lenalidomide for pharmacokinetics and toxicokinetic studies. Ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS is a preeminent analytical tool for rapid biomedical analysis. Results A simple, highly sensitive UPLC-MS/MS method was developed and validated for the determination of LND in rabbit and human plasma. After a simple protein precipitation using methanol, LND and carbamazepine (IS were separated on Acquity UPLC BEH™ C18 column (50 × 2.1 mm, i.d. 1.7 μm, Waters, USA using a mobile phase consisted of acetonitrile:water:formic acid (65:35:0.1%, v/v/v pumped at a flow rate of 0.2 mL/min. LND and IS were eluted at 0.71 and 1.92 min, respectively. The mass spectrometric determination was carried out using an electrospray interface operated in the positive mode with multiple reaction monitoring (MRM mode. The precursor to product ion transitions of m/z 260.1 > 149.0 and m/z 237.0 > 179.0 were used to quantify LND and IS, respectively. The method was linear in the concentration range of 0.23–1000 ng/mL with a limit of quantitation of 0.23 ng/mL. All the validation parameters were in the ranges acceptable by the guidelines of analytical method validation. Conclusion The proposed UPLC-MS/MS method is simple, rapid and highly sensitive, and hence it could be reliable for pharmacokinetic and toxicokinetic study in both animals and humans.

  10. Study of matrix effects on the direct trace analysis of acidic pesticides in water using various liquid chromatographic modes coupled to tandem mass spectrometric detection.

    Science.gov (United States)

    Dijkman, E; Mooibroek, D; Hoogerbrugge, R; Hogendoorn, E; Sancho, J V; Pozo, O; Hernández, F

    2001-08-10

    This study investigated the effects of matrix interferences on the analytical performance of a triple quadrupole mass spectrometric (MS-MS) detector coupled to various reversed-phase liquid chromatographic (LC) modes for the on-line determination of various types of acidic herbicides in water using external calibration for quantification of the analytes tested at a level of 0.4 microg/l. The LC modes included (i) a single-column configuration (LC), (ii) precolumn switching (PC-LC) and (iii) coupled-column LC (LC-LC). As regards detection, electrospray (ESI) and atmospheric pressure chemical ionization (APCI) in both positive (PI) and negative (NI) ionization modes were examined. Salinity and dissolved organic carbon (DOC) were selected as interferences to study matrix effects in this type of analysis. Therefore, Milli-Q and tap water samples both fortified with 12 mg/l DOC and spiked with sulfometuron-methyl, bentazone, bromoxynil, 2-methyl-4-chlorophenoxyacetic acid, and 2-methyl-4-chlorophenoxypropionic acid at a level of about 0.4 microg/l were analyzed with the various LC-MS approaches. Direct sample injection was performed with volumes of 0.25 ml or 2.0 ml on a column of 2.1 mm I.D. or 4.6 mm I.D. for the ESI and APCI modes, respectively. The recovery data were used to compare and evaluate the analytical performance of the various LC approaches. As regards matrix effects, the salinity provided a dramatic decrease in response for early eluting analytes (k value of about 1) when using the LC mode. Both PC-LC and LC-LC efficiently eliminated this problem. The high DOC content hardly effected the responses of analytes in the ESI mode, while in most cases the responses increased when using APCI-MS-MS detection. Of all the tested configurations, LC-LC-ESI-MS-MS with the column combination Discovery C18/ABZ+ was the most favorable as regards elimination of matrix effects and provided reliable quantification of all compounds using external calibration at the tested

  11. Liquid chromatographic-tandem mass spectrometric method for the simultaneous determination of alkylphenols polyethoxylates, alkylphenoxy carboxylates and alkylphenols in wastewater and surface-water.

    Science.gov (United States)

    Ciofi, L; Ancillotti, C; Chiuminatto, U; Fibbi, D; Checchini, L; Orlandini, S; Del Bubba, M

    2014-10-03

    Four different pellicular stationary phases (i.e. octadecylsilane, octasilane, Phenyl-Hexyl and pentafluorophenyl) were investigated for the chromatographic resolution of alkylphenols (APs), alkylphenols polyethoxylates (APnEOs) and alkylphenoxy carboxylates (APECs) using mixtures of water and organic solvents (i.e. methanol, acetonitrile and tetrahydrofuran) as eluents, in order to obtain their determination by a single LC-MS/MS run. In fact, alkylphenols and alkylphenoxy carboxylates must be analysed in negative ion mode, whereas alkylphenols polyethoxylates undergo ionisation only in positive ion mode, and therefore, two distinct LC-MS/MS analysis are commonly adopted. The best resolution among the aforementioned target analytes was achieved on the pentafluorophenyl column, eluting with an acidified water-acetonitrile-tetrahydrofuran mixture and using the post column addition of an ammonia solution in methanol for the detection of positively ionisable compounds. Under these optimized chromatographic conditions the investigated compounds were determined via a single chromatographic run, with only one polarity switch, in 15min, achieving the following instrumental detection limits: 600pg for AP1EOs, 0.8-14pg for AP2EOs, 10.4-150pg for APs and 4.4-4.8pg for APECs. The chromatographic method was coupled with solid-phase extraction and clean-up procedures and successfully applied to the analysis of wastewater and surface water samples, highlighting mean concentration ranging from 6ng/L for 4-t-OP1EC to 1434ng/L for 4-NP1121EC, depending on the sample analysed. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. MultiSimplex optimization of chromatographic separation and dansyl derivatization conditions in the ultra performance liquid chromatography-tandem mass spectrometry analysis of risperidone, 9-hydroxyrisperidone, monoamine and amino acid neurotransmitters in human urine.

    Science.gov (United States)

    Cai, Hua-Lin; Zhu, Rong-Hua; Li, Huan-De; Zhang, Jun; Li, Lan-Fang

    2011-07-01

    A pre-column dansylated ultra-performance liquid chromatography-electrospray ionization tandem mass spectrometry (UPLC-MS/MS) method for simultaneous determination of risperidone (RIP), 9-hydroxyrisperidone (9-OH-RIP), monoamine and amino acid neurotransmitters in human urine was developed with the aim of providing data on how neurotransmitters may influence each other or change simultaneously in response to risperidone treatment. MultiSimplex based on the simplex algorithm and the fuzzy set theory was applied to the optimization of chromatographic separation and dansyl derivatization conditions during method development. This method exhibited excellent linearity for all the analytes with regression coefficients higher than 0.997. The lower limit of quantification (LLOQ) values for 9-OH-RIP and RIP were 0.11 and 0.06 ng/ml, respectively, and for neurotrasmitters ranged from 0.31 to 12.8 nM. The mean accuracy ranged from 94.7% to 108.5%. The mean recovery varied between 81.6% and 97.5%. All the RSD of precision and stability were below 9.7%. Finally, the optimized method was applied to analyze the first morning urine samples of schizophrenic patients treated with risperidone and healthy volunteers. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. Liquid chromatographic-mass spectrometric method for ...

    African Journals Online (AJOL)

    Tropical Journal of Pharmaceutical Research ... Purpose: To develop and validate a simple, efficient and reliable Liquid chromatographic-mass spectrometric (LC-MS/MS) method for the quantitative determination of two dermatological drugs, ... By Country · List All Titles · Free To Read Titles This Journal is Open Access.

  14. Liquid chromatographic analysis of phenobarbitone, ethosuximide ...

    African Journals Online (AJOL)

    A liquid chromatographic method for the simultaneous assay of four anticonvulsant drugs, phenobarbitone, ethosuximide, phenytoin and carbamazepine on a polystyrene-divinyl benzene column is described. The method was developed by the systematic study of different types of co-polymer materials, type and ...

  15. Validated high performance liquid chromatographic (HPLC) method ...

    African Journals Online (AJOL)

    STORAGESEVER

    2010-02-22

    Feb 22, 2010 ... specific and accurate high performance liquid chromatographic method for determination of ZER in micro-volumes ... tional medicine as a cure for swelling, sores, loss of appetite and ... Receptor Activator for Nuclear Factor κ B Ligand .... The effect of ... be suitable for preclinical pharmacokinetic studies. The.

  16. Liquid chromatographic/electrospray ionization quadrupole/time of flight tandem mass spectrometric study of polyphenolic composition of different Vaccinium berry species and their comparative evaluation.

    Science.gov (United States)

    Ancillotti, Claudia; Ciofi, Lorenzo; Rossini, Daniele; Chiuminatto, Ugo; Stahl-Zeng, Jianru; Orlandini, Serena; Furlanetto, Sandra; Del Bubba, Massimo

    2017-02-01

    Ultra-high-performance liquid chromatography coupled with high-resolution quadrupole-time of flight mass spectrometry with both negative and positive ionization was used for comprehensively investigating the phenolic and polyphenolic compounds in berries from three spontaneous or cultivated Vaccinium species (i.e., Vaccinium myrtillus, Vaccinium uliginosum subsp. gaultherioides, and Vaccinium corymbosum). More than 200 analytes, among phenolic and polyphenolic compounds belonging to the classes of anthocyanins, monomeric and oligomeric flavonols, flavanols, dihydrochalcones, phenolic acids, together with other polyphenolic compounds of mixed structural characteristics, were identified. Some of the polyphenols herein investigated, such as anthocyanidin glucuronides and malvidin-feruloyl-hexosides in V. myrtillus, or anthocyanindin aldopentosides and coumaroyl-hexosides in V. uliginosum subsp. gaultherioides and a large number of proanthocyanidins with high molecular weight in all species, were described for the first time in these berries. Principal component analysis applied on original LC-TOF data, acquired in survey scan mode, successfully discriminated the three Vaccinium berry species investigated, on the basis of their polyphenolic composition, underlying one more time the fundamental role of mass spectrometry for food characterization.

  17. Development, validation and application of an ultra high performance liquid chromatographic-tandem mass spectrometric method for the simultaneous detection and quantification of five different classes of veterinary antibiotics in swine manure.

    Science.gov (United States)

    Van den Meersche, Tina; Van Pamel, Els; Van Poucke, Christof; Herman, Lieve; Heyndrickx, Marc; Rasschaert, Geertrui; Daeseleire, Els

    2016-01-15

    In this study, a fast, simple and selective ultra high performance liquid chromatographic-tandem mass spectrometric (UHPLC-MS/MS) method for the simultaneous detection and quantification of colistin, sulfadiazine, trimethoprim, doxycycline, oxytetracycline and ceftiofur and for the detection of tylosin A in swine manure was developed and validated. First, a simple extraction procedure with acetonitrile and 6% trichloroacetic acid was carried out. Second, the supernatant was evaporated and the pellet was reconstituted in 1 ml of water/acetonitrile (80/20) and 0.1% formic acid. Extracts were filtered and analyzed by UHPLC-MS/MS on a Kinetex C18 column using gradient elution. The method developed was validated according to the criteria of Commission Decision 2002/657/EC. Recovery percentages varied between 94% and 106%, repeatability percentages were within the range of 1.7-9.2% and the intralaboratory reproducibility varied between 2.8% and 9.3% for all compounds, except for tylosin A for which more variation was observed resulting in a higher measurement uncertainty. The limit of detection and limit of quantification varied between 1.1 and 20.2 and between 3.5 and 67.3 μg/kg, respectively. This method was used to determine the presence and concentration of the seven antibiotic residues in swine manure sampled from ten different manure pits on farms where the selected antibiotics were used. A link was found between the antibiotics used and detected, except for ceftiofur which is injected at low doses and degraded readily in swine manure and was therefore not recovered in any of the samples. To the best of our knowledge, this is the first method available for the simultaneous extraction and quantification of colistin with other antibiotic classes. Additionally, colistin was never extracted from swine manure before. Another innovative aspect of this method is the simultaneous detection and quantification of five different classes of antibiotic residues in swine manure

  18. Dual quantification of dapivirine and maraviroc in cervicovaginal secretions from ophthalmic tear strips and polyester-based swabs via liquid chromatographic-tandem mass spectrometric (LC-MS/MS) analysis.

    Science.gov (United States)

    Parsons, Teresa L; Emory, Joshua F; Seserko, Lauren A; Aung, Wutyi S; Marzinke, Mark A

    2014-09-01

    Topical microbicidal agents are being actively pursued as a modality to prevent HIV viral transmission during sexual intercourse. Quantification of antiretroviral agents in specimen sources where antiviral activity is elicited is critical, and drug measurements in cervicovaginal fluid can provide key information on local drug concentrations. Two antiretroviral drugs, dapivirine and maraviroc, have gained interest as vaginal microbicidal agents, and rugged methods are required for their quantification in cervicovaginal secretions. Cervicovaginal fluid spiked with dapivirine and maraviroc were applied to ophthalmic tear strips or polyester-based swabs to mimic collection procedures used in clinical studies. Following sample extraction and the addition of isotopically labeled internal standards, samples were subjected to liquid chromatographic-tandem mass spectrometric (LC-MS/MS) analysis using a Waters BEH C8, 50mm×2.1mm, 1.7μm particle size column, on an API 4000 mass analyzer operated in selective reaction monitoring mode. The method was validated according to FDA Bioanalytical Method Validation guidelines. Due to the disparate saturation capacity of the tested collection devices, the analytical measuring ranges for dapivirine and maravirocin cervicovaginal fluid on the ophthalmic tear strip were 0.05-25ng/tear strip, and 0.025-25ng/tear strip, respectively. As for the polyester-based swab, the analytical measuring ranges were 0.25-125ng/swab for dapivirine and 0.125-125ng/swab for maraviroc. Dilutional studies were performed for both analytes to extended ranges of 25,000ng/tear strip and 11,250ng/swab. Standard curves were generated via weighted (1/x(2)) linear or quadratic regression of calibrators. Precision, accuracy, stability and matrix effects studies were all performed and deemed acceptable according to the recommendations of the FDA Bioanalytical Method Validation guidelines. A rugged LC-MS/MS method for the dual quantification of dapivirine and

  19. Development and validation of a sensitive liquid chromatographic-tandem mass spectrometric method for the simultaneous analysis of granisetron and 7-hydroxy granisetron in human plasma and urine samples: application in a clinical pharmacokinetic study in pregnant subject.

    Science.gov (United States)

    Zhao, Yang; Chen, Hui-Jun; Caritis, Steve; Venkataramanan, Raman

    2016-02-01

    A liquid chromatography-tandem mass spectrometric method for the quantification of granisetron and its major metabolite, 7-hydroxy granisetron in human plasma and urine samples was developed and validated. Respective stable isotopically labeled granisetron and 7-hydroxy granisetron were used as internal standards (IS). Chromatography was performed using an Xselect HSS T3 analytical column with a mobile phase of 20% acetonitrile in water (containing 0.2 mM ammonium formate and 0.14% formic acid, pH 4) delivered in an isocratic mode. Tandem mass spectrometry operating in positive electrospray ionization mode with multiple reaction monitoring was used for quantification. The standard curves were linear in the concentration ranges of 0.5-100 ng/mL for granisetron and 0.1-100 ng/mL for 7-hydroxy granisetron in human plasma samples, and 2-2000 ng/mL for granisetron and 2-1000 ng/mL for 7-hydroxy granisetron in human urine samples, respectively. The accuracies were >85% and the precision as determined by the coefficient of variations was granisetron or 7-hydroxy granisetron in either plasma or urine samples. Granisetron was stable under various storage and experimental conditions. This validated method was successfully applied to a pharmacokinetic study after intravenous administration of 1 mg granisetron to a pregnant subject. Copyright © 2015 John Wiley & Sons, Ltd.

  20. Determination of biocides as well as some biocide metabolites from facade run-off waters by solid phase extraction and high performance liquid chromatographic separation and tandem mass spectrometry detection.

    Science.gov (United States)

    Bester, K; Lamani, X

    2010-08-06

    Biocides are used to protect buildings, boats, and other materials from microbial infestations. A huge variety of compounds are being used: isothiazolinones, e.g., to prevent bacterial growth in paints, triazines and phenylureas against algal growth on water exposed materials while carbamates are used against fungal investations. However these biocides can be leached from the respective materials. As these are very effective compounds it is important to know the concentrations of these biocides in the leachates as well as their leaching behaviour to assess their risk to the environment. In this study, a method for the determination of biocides from facade material run-off water by means of high performance liquid chromatography coupled to tandem mass spectrometry (HPLC-MS/MS) was developed. Due to the amphiphilic character and the expected varying pH-values in the samples, the extractions as well as the HPLC-method development proved to be demanding. The water samples (leachates) were buffered with a phosphate buffer to pH 7. As some of the biocides are very hydrophilic, different SPE cartridges were tested to identify the SPE material with the highest recovery rates for all compounds. For gaining a good separation, analyte trapping was performed on the HPLC column. Quantification was performed using a mass spectrometer in multi-reaction monitoring with two transitions per compound. The final recovery rates were conducted using a cartridge with a divenylbenzyl polymer sorbent. A combination of methanol and acetonitrile as eluents was used to reach recovery rates in the range of 70-100%. The limit of quantification for the compounds of interest ranged from 0.01 to 0.1 microg/L. Copyright 2010 Elsevier B.V. All rights reserved.

  1. Sensitive high performance liquid chromatographic method for the ...

    African Journals Online (AJOL)

    A new simple, sensitive, cost-effective and reproducible high performance liquid chromatographic (HPLC) method for the determination of proguanil (PG) and its metabolites, cycloguanil (CG) and 4-chlorophenylbiguanide (4-CPB) in urine and plasma is described. The extraction procedure is a simple three-step process ...

  2. Development and Validation of a Liquid Chromatographic Method ...

    African Journals Online (AJOL)

    A liquid chromatographic method for the simultaneous determination of six human immunodeficiency virus (HIV) protease inhibitors, indinavir, saquinavir, ritonavir, amprenavir, nelfinavir and lopinavir, was developed and validated. Optimal separation was achieved on a PLRP-S 100 Å, 250 x 4.6 mm I.D. column maintained ...

  3. High performance liquid chromatographic determination of ...

    African Journals Online (AJOL)

    STORAGESEVER

    2010-02-08

    ) high performance liquid chromatography (HPLC) grade .... applications. These are important requirements if the reagent is to be applicable to on-line pre or post column derivatisation in a possible automation of the analytical.

  4. Micro-column plasma emission liquid chromatograph. [Patent application

    Science.gov (United States)

    Gay, D.D.

    1982-08-12

    In a direct current plasma emission spectrometer for use in combination with a microcolumn liquid chromatograph, an improved plasma source unit is claimed. The plasma source unit includes a quartz capillary tube having an inlet means, outlet off gas means and a pair of spaced electrodes defining a plasma region in the tube. The inlet means is connected to and adapted to receive eluant of the liquid chromatograph along with a stream of plasma-forming gas. There is an opening through the wall of the capillary tube penetrating into the plasma region. A soft glass capillary light pipe is disposed at the opening, is connected to the spectrometer, and is adapted to transmit light passing from the plasma region to the spectrometer. There is also a source of electromotive force connected to the electrodes sufficient to initiate and sustain a plasma in the plasma region of the tube.

  5. Chiral ionic liquids in chromatographic and electrophoretic separations.

    Science.gov (United States)

    Kapnissi-Christodoulou, Constantina P; Stavrou, Ioannis J; Mavroudi, Maria C

    2014-10-10

    This report provides an overview of the application of chiral ionic liquids (CILs) in separation technology, and particularly in capillary electrophoresis and both gas and liquid chromatography. There is a large number of CILs that have been synthesized and designed as chiral agents. However, only a few have successfully been applied in separation technology. Even though this application of CILs is still in its early stages, the scientific interest is increasing dramatically. This article is focused on the use of CILs as chiral selectors, background electrolyte additives, chiral ligands and chiral stationary phases in electrophoretic and chromatographic techniques. Different examples of CILs, which contain either a chiral cation, a chiral anion or both, are presented in this review article, and their major advantages along with their potential applications in chiral electrophoretic and chromatographic recognition are discussed. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Applicability of the direct injection liquid chromatographic tandem mass spectrometric analytical approach to the sub-ngL-1 determination of perfluoro-alkyl acids in waste, surface, ground and drinking water samples.

    Science.gov (United States)

    Ciofi, Lorenzo; Renai, Lapo; Rossini, Daniele; Ancillotti, Claudia; Falai, Alida; Fibbi, Donatella; Bruzzoniti, Maria Concetta; Santana-Rodriguez, José Juan; Orlandini, Serena; Del Bubba, Massimo

    2018-01-01

    The applicability of a direct injection UHPLC-MS/MS method for the analysis of several perfluoroalkyl acids (PFAAs) in a wide range of water matrices was investigated. The method is based on the direct injection of 100µL of centrifuged water sample, without any other sample treatment. Very good method detection limits (0.014-0.44ngL -1 ) and excellent intra and inter-day precision (RSD% values in the range 1.8-4.4% and 2.7-5.7%, respectively) were achieved, with a total analysis time of 20min per sample. A high number of samples - i.e. 8 drinking waters (DW), 12 ground waters (GW), 13 surface waters (SW), 8 influents and 11 effluents of wastewater treatment plants (WWTP IN and WWTP OUT ) were processed and the extent of matrix effect (ME) was calculated, highlighting the strong prevalence of |ME| 50% was occasionally observed only for perfluorooctanesulphonic and perfluorodecanoic acids. Linear discriminant analysis highlighted the great contribution of the sample origin (i.e. DW, GW, SW, WWTP IN and WWTP OUT ) to the ME. Partial least square regression (PLS) and leave-one-out cross-validation were performed in order to interpret and predict the signal suppression or enhancement phenomena as a function of physicochemical parameters of water samples (i.e. conductivity, hardness and chemical oxygen demand) and background chromatographic area. The PLS approach resulted only in an approximate screening, due to the low prediction power of the PLS models. However, for most analytes in most samples, the fitted and cross-validated values were such as to correctly distinguish between | ME | higher than 20% or below this limit. PFAAs in the aforementioned water samples were quantified by means of the standard addition method, highlighting their occurrence mainly in WWTP influents and effluents, at concentrations as high as one hundred of µgL -1 . Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Determination of hexachlorocyclohexane pesticide residues in wool fat by a combined high-performance liquid chromatographic-gas-liquid chromatographic method

    International Nuclear Information System (INIS)

    Ali, S.L.

    1978-01-01

    Beta- and gamma-hexachlorocyclohexane residues were determined in twelve wool fat samples by using a combined high-performance liquid chromatographic (HPLC)-gas-liquid chromatographic (GLC) method. After extraction and chromatographic clean-up on a silca-gel column, the sample was further purified by HPLC on a reversed-phase C-18 column with methanol as the mobile phase. The final determination was effected by GLC with a 1-mCi nickel-63 electron-capture detector. The analytical method was checked by addition of carbon-14-labelled lindane and measurement of the radioactivity in a liquid scintillation counter. (Auth.)

  8. Liquid chromatographic-tandem mass spectrometric assay for ...

    African Journals Online (AJOL)

    for simultaneous quantitation of tofacitinib, cabozantinib ... The method was validated with regard to its limits of .... quantitative determination of TOF alone was .... prepared in human plasma only. Blank plasma/urine samples were similarly ...

  9. High-performance liquid chromatographic method for guanylhydrazone compounds.

    Science.gov (United States)

    Cerami, C; Zhang, X; Ulrich, P; Bianchi, M; Tracey, K J; Berger, B J

    1996-01-12

    A high-performance liquid chromatographic method has been developed for a series of aromatic guanylhydrazones that have demonstrated therapeutic potential as anti-inflammatory agents. The compounds were separated using octadecyl or diisopropyloctyl reversed-phase columns, with an acetonitrile gradient in water containing heptane sulfonate, tetramethylammonium chloride, and phosphoric acid. The method was used to reliably quantify levels of analyte as low as 785 ng/ml, and the detector response was linear to at least 50 micrograms/ml using a 100 microliters injection volume. The assay system was used to determine the basic pharmacokinetics of a lead compound, CNI-1493, from serum concentrations following a single intravenous injection in rats.

  10. Derivatization reagents in liquid chromatography/electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Santa, Tomofumi

    2011-01-01

    Liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) is one of the most prominent analytical techniques owing to its inherent selectivity and sensitivity. In LC/ESI-MS/MS, chemical derivatization is often used to enhance the detection sensitivity. Derivatization improves the chromatographic separation, and enhances the mass spectrometric ionization efficiency and MS/MS detectability. In this review, an overview of the derivatization reagents which have been applied to LC/ESI-MS/MS is presented, focusing on the applications to low molecular weight compounds. 2010 John Wiley & Sons, Ltd.

  11. Liquid chromatographic determination of sennosides in Cassia angustifolia leaves.

    Science.gov (United States)

    Srivastava, Alpuna; Pandey, Richa; Verma, Ram K; Gupta, Madan M

    2006-01-01

    A simple liquid chromatographic method was developed for the determination of sennosides B and A in leaves of Cassia angustifolia. These compounds were extracted from leaves with a mixture of methanol-water (70 + 30, v/v) after defatting with hexane. Analyte separation and quantitation were achieved by gradient reversed-phase liquid chromatography and UV absorbance at 270 nm using a photodiode array detector. The method involves the use of an RP-18 Lichrocart reversed-phase column (5 microm, 125 x 4.0 mm id) and a binary gradient mobile-phase profile. The various other aspects of analysis, namely, peak purity, similarity, recovery, repeatability, and robustness, were validated. Average recoveries of 98.5 and 98.6%, with a coefficient of variation of 0.8 and 0.3%, were obtained by spiking sample solution with 3 different concentration solutions of standards (60, 100, and 200 microg/mL). Detection limits were 10 microg/mL for sennoside B and 35 microg/mL for sennoside A, present in the sample solution. The quantitation limits were 28 and 100 microg/mL. The analytical method was applied to a large number of senna leaf samples. The new method provides a reliable tool for rapid screening of C. angustifolia samples in large numbers, which is needed in breeding/genetic engineering and genetic mapping experiments.

  12. Analysis of 2-methylthio-derivatives of isoprenoid cytokinins by liquid chromatography-tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Tarkowski, Petr, E-mail: petr.tarkowski@upol.cz [Laboratory of Growth Regulators, Palacky University and Institute of Experimental Botany ASCR, Slechtitelu 11, 783 71 Olomouc (Czech Republic); Department of Biochemistry, Faculty of Science, Palacky University, Slechtitelu 11, 783 71 Olomouc (Czech Republic); Vaclavikova, Katerina, E-mail: katka.vaclavik@seznam.cz [Laboratory of Growth Regulators, Palacky University and Institute of Experimental Botany ASCR, Slechtitelu 11, 783 71 Olomouc (Czech Republic); Department of Biochemistry, Faculty of Science, Palacky University, Slechtitelu 11, 783 71 Olomouc (Czech Republic); Novak, Ondrej, E-mail: ondrej.novak@upol.cz [Laboratory of Growth Regulators, Palacky University and Institute of Experimental Botany ASCR, Slechtitelu 11, 783 71 Olomouc (Czech Republic); Pertry, Ine, E-mail: ine.pertry@ugent.BE [Department of Plant Biotechnology and Genetics, Ghent University, K.L.Ledeganckstraat 35, B-9000 Gent (Belgium); Hanus, Jan, E-mail: helehan@seznam.cz [Isotope Laboratory, Institute of Experimental Botany ASCR, Videnska 1083, 142 20 Prague (Czech Republic); Whenham, Robert [Apex Organics, Devon, England (United Kingdom); Vereecke, Danny, E-mail: danny.vereecke@hogent.BE [Department of Plant Production, University College Ghent, Ghent University, Schoonmeersstraat 52, B-9000 Gent (Belgium); Sebela, Marek, E-mail: marek.sebela@upol.cz [Department of Biochemistry, Faculty of Science, Palacky University, Slechtitelu 11, 783 71 Olomouc (Czech Republic); Strnad, Miroslav, E-mail: miroslav.strnad@upol.cz [Laboratory of Growth Regulators, Palacky University and Institute of Experimental Botany ASCR, Slechtitelu 11, 783 71 Olomouc (Czech Republic)

    2010-11-08

    A sensitive and reliable high-performance liquid chromatographic method with tandem mass spectrometric detection has been developed and used for the determination of 2-methylthio-cytokinin derivatives produced by the phytopathogenic actinomycete Rhodococcus fascians. The cultivation medium containing secreted cytokinins was concentrated and subjected to a solid-phase extraction (C18 and ion-exchange). The purified samples were further separated and analyzed by HPLC-ESI-MS/MS. This allowed to achieve chromatographic resolution of six highly hydrophobic cytokinin species including 2-methylthio-isopentenyladenine, 2-methylthio-isopentenyladenosine, 2-methylthio-trans-zeatin and 2-methylthio-trans-zeatin riboside and their cis-isomers when a reversed-phase chromatographic column (C4) and a mobile phase consisting of acetonitrile and 20 mM ammonium formate, pH 5, were used. Quantification was performed by a standard isotope dilution method using a multiple-reaction monitoring (MRM) mode. In the MRM mode, limits of detection reached 20-30 fmol and linear ranges spanned four orders of magnitude. Recovery values were between 35% and 65% and the analytical accuracy between 95% and 149%. The proposed bioanalytical method, which takes advantage of effective chromatographic separation of six 2-methyltio-derivatives (including isomers of zeatin-type cytokinins) and sensitive mass spectrometric detection, may become useful for plant biologists studying the significance of these substances in plant-microbe interactions.

  13. Analysis of 2-methylthio-derivatives of isoprenoid cytokinins by liquid chromatography-tandem mass spectrometry

    International Nuclear Information System (INIS)

    Tarkowski, Petr; Vaclavikova, Katerina; Novak, Ondrej; Pertry, Ine; Hanus, Jan; Whenham, Robert; Vereecke, Danny; Sebela, Marek; Strnad, Miroslav

    2010-01-01

    A sensitive and reliable high-performance liquid chromatographic method with tandem mass spectrometric detection has been developed and used for the determination of 2-methylthio-cytokinin derivatives produced by the phytopathogenic actinomycete Rhodococcus fascians. The cultivation medium containing secreted cytokinins was concentrated and subjected to a solid-phase extraction (C18 and ion-exchange). The purified samples were further separated and analyzed by HPLC-ESI-MS/MS. This allowed to achieve chromatographic resolution of six highly hydrophobic cytokinin species including 2-methylthio-isopentenyladenine, 2-methylthio-isopentenyladenosine, 2-methylthio-trans-zeatin and 2-methylthio-trans-zeatin riboside and their cis-isomers when a reversed-phase chromatographic column (C4) and a mobile phase consisting of acetonitrile and 20 mM ammonium formate, pH 5, were used. Quantification was performed by a standard isotope dilution method using a multiple-reaction monitoring (MRM) mode. In the MRM mode, limits of detection reached 20-30 fmol and linear ranges spanned four orders of magnitude. Recovery values were between 35% and 65% and the analytical accuracy between 95% and 149%. The proposed bioanalytical method, which takes advantage of effective chromatographic separation of six 2-methyltio-derivatives (including isomers of zeatin-type cytokinins) and sensitive mass spectrometric detection, may become useful for plant biologists studying the significance of these substances in plant-microbe interactions.

  14. Determination of thromboxanes, leukotrienes and lipoxins using high-temperature capillary liquid chromatography-tandem mass spectrometry and on-line sample preparation

    DEFF Research Database (Denmark)

    Dahl, Sandra Rinne; Kleiveland, Charlotte Ramstad; Kassem, Moustapha

    2009-01-01

    An on-line strong cation-exchange (SCX)-reversed-phase (RP) capillary liquid chromatographic (cLC) method with ion-trap tandem mass spectrometric (IT-MS/MS) detection for the simultaneous determination of thromboxane (TX) B(2), TXB(3), leukotriene (LT) B(4), LTD(4) and lipoxin (LX) A(4) in cell...

  15. Liquid chromatographic separation of zalcitabine and its stereoisomers.

    Science.gov (United States)

    Scypinski, S; Ross, A J

    1994-10-01

    A liquid chromatographic method capable of separating and quantitating the stereoisomers of zalcitabine has been developed and validated. The separation was achieved with an Astec Cyclobond I--RSP column and a mobile phase of 0.25% triethylamine in water adjusted to a pH of 6.5 with glacial acetic acid. All enantiomers were found to exhibit a linear response in the range of 0.1-10% in the presence of 100% zalcitabine. Precision of analysis was found to be less than 1.5% at a level of 1% relative to zalcitabine. The limit of detection for two of the three enantiomeric impurities was determined to be 0.05% relative to zalcitabine. The detection limit for the third was found to be 0.1%. This method was successfully applied to the analysis of reference standards and several production scale batches. All of these materials were found to be stereochemically pure to a level of 99.8% or better.

  16. Comprehensive two-dimensional liquid chromatographic analysis of poloxamers.

    Science.gov (United States)

    Malik, Muhammad Imran; Lee, Sanghoon; Chang, Taihyun

    2016-04-15

    Poloxamers are low molar mass triblock copolymers of poly(ethylene oxide) (PEO) and poly(propylene oxide) (PPO), having number of applications as non-ionic surfactants. Comprehensive one and two-dimensional liquid chromatographic (LC) analysis of these materials is proposed in this study. The separation of oligomers of both types (PEO and PPO) is demonstrated for several commercial poloxamers. This is accomplished at the critical conditions for one of the block while interaction for the other block. Reversed phase LC at CAP of PEO allowed for oligomeric separation of triblock copolymers with regard to PPO block whereas normal phase LC at CAP of PPO renders oligomeric separation with respect to PEO block. The oligomeric separation with regard to PEO and PPO are coupled online (comprehensive 2D-LC) to reveal two-dimensional contour plots by unconventional 2D IC×IC (interaction chromatography) coupling. The study provides chemical composition mapping of both PEO and PPO, equivalent to combined molar mass and chemical composition mapping for several commercial poloxamers. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. High performance liquid chromatographic determination of glucosamine in rat plasma.

    Science.gov (United States)

    Aghazadeh-Habashi, Ali; Sattari, Saeed; Pasutto, Franco; Jamali, Fakhreddin

    2002-01-01

    A high performance liquid chromatographic method was developed for the determination of glucosamine (GlcN) in rat plasma. Internal standard, galactosamine, was added to 100 micro L of plasma containing GlcN followed by precipitation of plasma proteins with acetonitrile. Evaporation of the decanted supernatant solution was accelerated by the addition of methanol. GlcN was derivatized by addition of a solution containing 1-naphthyl isothiocyanate. Sample cleanup included passage through an anion exchange cartridge. Analysis was accomplished by injection of 0.1 mL of the sample solution into an isocratic HPLC system consisting of a C18 column, a mobile phase of acetonitrile: water: acetic acid: triethylamine (4.5: 95.5:0.1:0.05), a flow rate of 0.9 mL/min, and a UV detector set at 254 nm. Galactosamine and GlcN appeared 26 and 29 min post-injection, respectively. The assay was linear over the range of 1.25-400 micro g/mL (CV<10%) with a detection limit of 0.63 microg/mL and a limit of quantification of 1.25 microg/mL. The method was applied to the determination of GlcN in rat plasma after oral administration of 350 mg/kg of GlcN hydrochloride. The present assay is specific, sensitive, precise, and accurate and is suitable for pharmacokinetic studies.

  18. High-pressure liquid chromatographic assay of Bay n 7133 in human serum.

    OpenAIRE

    Fasching, C E; Hughes, C E; Hector, R F; Peterson, L R

    1984-01-01

    A high-pressure liquid chromatographic method that includes a Sep-Pak (Waters Associates, Inc., Milford , Mass.) preparation of human serum was employed for the quantitative assay of Bay n 7133. Drug levels of 0.1 to 20 micrograms/ml could be detected. No interference from amphotericin B was found in the chromatographic analysis of Bay n 7133.

  19. Liquid chromatographic determination of seven antioxidants in dry food.

    Science.gov (United States)

    Page, B D; Charbonneau, C F

    1989-01-01

    The liquid chromatographic determinative step of the official method for propyl gallate, trihydroxybutyrophenone, tert-butylhydroquinone, nordihydroguaiaretic acid, butylated hydroxyanisole (BHA), 3,5-di-tert-butyl-4-hydroxymethylphenol, and butylated hydroxytoluene (BHT) in fats and oils has been applied to their determination in a number of dry foods. A representative sample (10 g) is homogenized first with hexane (25 mL), then with 5 mL added water, and finally with 75 mL added acetonitrile. The hexane and acetonitrile are decanted, filtered, and separated; the hexane and rehydrated food are reextracted with 2 additional portions of acetonitrile, and the combined acetonitrile extracts are concentrated and diluted to 10 mL. An aliquot is analyzed as described in the official method, using a 150 x 4.6 mm 5 microns C-18 column. The need for rehydration to maximize the recovery of BHA and other antioxidants from marketplace dry food samples such as potato flakes, dry coffee whiteners, and dessert topping mixes was demonstrated. Rehydration was not required for cheese snacks, breakfast cereals, cake mixes, and some other foods. The need for rehydration should be determined by analyzing other foods with and without the addition of water. Potato and corn chips, popcorn and cheese snacks, breakfast cereals, dry beverage mixes, rice, potato flakes, french fried potatoes, and cake mixes were spiked with the above antioxidants at 10-50 ppm. Overall recoveries ranged from 64.3 to 105.6% and repeatabilities ranged from 0.7 to 10.8%. A total of 109 samples of the above foods were analyzed, and 64% contained detectable (greater than 1-2 ppm) antioxidants, mainly BHA and BHT.

  20. Ultra Performance Liquid Chromatography Tandem Mass ...

    African Journals Online (AJOL)

    NICOLAAS

    drugs alone.16. After a single oral dose of 120–800 mg of NTB in healthy sub- jects in a fasting state the peak plasma NTB concentration (tmax) was found to be 4–7 h, with a half-life of approximately 9–17 h.17 ... performance liquid chromatography mass spectrometry/mass .... to the likely biological plasma constituents.

  1. Determination of albendazole sulfoxide in human plasma by using liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Saraner, Nihal; Özkan, Güler Yağmur; Güney, Berrak; Alkan, Erkin; Burul-Bozkurt, Nihan; Sağlam, Onursal; Fikirdeşici, Ezgi; Yıldırım, Mevlüt

    2016-06-01

    A rapid, simple and sensitive method was developed and validated using liquid chromatography-tandem mass spectrometry (LC-MS/MS) for determination of albendazole sulfoxide (ABZOX) in human plasma. The plasma samples were extracted by protein precipitation using albendazole sulfoxide-d3 as internal standard (IS). The chromatographic separation was performed on Waters Xbridge C18Column (100×4.6mm, 3.5μm) with a mobile phase consisting of ammonia solution, water and methanol at a flow rate of 0.70mL/min. ABZOX was detected and identified by mass spectrometry with electrospray ionization (ESI) in positive ion and multiple-reaction monitoring (MRM) mode. The method was linear in the range of 3-1500ng/mL for ABZOX. This method was successfully applied to the bioequivalence study in human plasma samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Measurement Uncertainty of Liquid Chromatographic Analyses Visualized by Ishikawa Diagrams

    OpenAIRE

    Meyer, Veronika R.

    2017-01-01

    Ishikawa, or cause-and-effect diagrams, help to visualize the parameters that influence a chromatographic analysis. Therefore, they facilitate the set up of the uncertainty budget of the analysis, which can then be expressed in mathematical form. If the uncertainty is calculated as the Gaussian sum of all uncertainty parameters, it is necessary to quantitate them all, a task that is usually not practical. The other possible approach is to use the intermediate precision as a base for the uncer...

  3. High Performance Liquid Chromatographic Method for Determination of Dipyridamole in Human Plasma

    Directory of Open Access Journals (Sweden)

    DAVOOD BEIGI BAND ARAB ADI

    1999-08-01

    Full Text Available A simple, rapid and specific high-performance liquid chromatographic procedure is reported for"nquantitative determination of dipyridamole in human -plasma. The assay uses a reversed-phase"nhigh-performance liquid chromatographic (HPLC and UV detection at 280nm and has a limit"nof detection of approximately 5ng/mL. The mobile phase consists of MeOH-H20 (60:40"nadjusted to pH 3.3. Dipyridamole was extracted from plasma by back-extraction procedure, with"npropranolol as the internal standard. The reproducibility of the method is satisfactory

  4. A gas/liquid chromatographic-mass spectrometric method for the rapid screening of 250 pesticides in aqueous matrices

    Energy Technology Data Exchange (ETDEWEB)

    Chandramouli, B.; Harvan, D.; Brittain, S.; Hass, R. [Eno River Labs, LLC. Durham, NC (United States)

    2004-09-15

    Pesticide residues in food present a potentially serious and significant cause for concern. Many pesticides have been associated with significant health effects to the nervous and endocrine systems and some have been deemed carcinogenic. There are many well-established techniques for pesticide analysis. However, commercial pesticide methods have traditionally only been available for specific pesticide families, such as chlorinated pesticides or herbicides, and at detection limits ranging from 0.05 ppb to 1 ppm in aqueous matrices. Techniques that can quickly screen for the presence/absence of pesticide residues in food matrices are critical in ensuring the safety of food and water. This paper outlines a combined Gas Chromatographic-High Resolution Mass Spectrometric (GC-HRMS) and Liquid Chromatographic Tandem Mass Spectrometric (LC-MS/MS) screening assay for 250 pesticides that was developed for use in water, and soda samples at screening levels ranging from 0.1-5 ppb. The pesticides selected have been identified by the European Union as being of concern and the target of possible legislation. The list encompasses a variety of pesticide classes and compound groupings.

  5. Determination of low-level acrylamide in drinking water by liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Lucentini, Luca; Ferretti, Emanuele; Veschetti, Enrico; Achene, Laura; Turrio-Baldassarri, Luigi; Ottaviani, Massimo; Bogialli, Sara

    2009-01-01

    A simple and sensitive liquid chromatographic-tandem mass spectrometric (LC/MS/MS) method has been developed and validated to confirm and quantify acrylamide monomer (AA) in drinking water using [13C3] acrylamide as internal standard (IS). After a preconcentration by solid-phase extraction with spherical activated carbon, analytes were chromatographed on IonPac ICE-AS1 column (9 x 250 mm) under isocratic conditions using acetonitrile-water-0.1 M formic acid (43 + 52 + 5, v/v/v) as the mobile phase. Analysis was achieved using a triple-quadrupole mass analyzer equipped with a turbo ion spray interface. For confirmation and quantification of the analytes, MS data acquisition was performed in the multireaction monitoring mode, selecting 2 precursor ion to product ion transitions for both AA and IS. The method was validated for linearity, sensitivity, accuracy, precision, extraction efficiency, and matrix effect. Linearity in tap water was observed over the concentration range 0.1-2.0 microg/L. Limits of detection and quantification were 0.02 and 0.1 microg/L, respectively. Interday and intraday assays were performed across 3 validation levels (0.1, 0.5, and 1.5 microg/L). Accuracy (as mean recovery) ranged from 89.3 to 96.2% with relative standard deviation water in compliance with European Union and U.S. Environmental Protection Agency standards.

  6. Determination of fluspirilene in human plasma by liquid chromatography-tandem mass spectrometry with electrospray ionisation.

    Science.gov (United States)

    Swart, K J; Sutherland, F C; van Essen, G H; Hundt, H K; Hundt, A F

    1998-12-18

    An ultra-sensitive method for the determination of fluspirilene in plasma was established, using high-performance liquid chromatographic separation with tandem mass spectrometric detection. The samples were extracted with hexane/isoamyl alcohol, separated on a Phenomenex Luna C18 5 mu 150 x 2.1 mm column with a mobile phase consisting of methanol-water-acetic acid (600:400:1) at a flow-rate of 0.3 ml/min. Detection was achieved by a Finnigan Matt mass spectrometer (LCQ) at unit resolution in full scan mode scanning the product ion spectrum from m/z 130-500 and monitoring the transition of the protonated molecular ion at m/z 476.2, to the sum of the largest product ions m/z 371, 342 and 274 (MS-MS). Electrospray ionisation was used for ion production. The mean recovery for fluspirilene was 90% with a lower limit of quantification of 21.50 pg/ml using 1 ml plasma for extraction. This is the first chromatographic method described for the determination of fluspirilene in plasma that is accurate and sensitive enough to be used in pharmacokinetic studies.

  7. Measurement uncertainty of liquid chromatographic analyses visualized by Ishikawa diagrams.

    Science.gov (United States)

    Meyer, Veronika R

    2003-09-01

    Ishikawa, or cause-and-effect diagrams, help to visualize the parameters that influence a chromatographic analysis. Therefore, they facilitate the set up of the uncertainty budget of the analysis, which can then be expressed in mathematical form. If the uncertainty is calculated as the Gaussian sum of all uncertainty parameters, it is necessary to quantitate them all, a task that is usually not practical. The other possible approach is to use the intermediate precision as a base for the uncertainty calculation. In this case, it is at least necessary to consider the uncertainty of the purity of the reference material in addition to the precision data. The Ishikawa diagram is then very simple, and so is the uncertainty calculation. This advantage is given by the loss of information about the parameters that influence the measurement uncertainty.

  8. Decomposition of pilocarpine eye drops assessed by a highly efficient high pressure liquid chromatographic method

    NARCIS (Netherlands)

    Kuks, P. F.; Weekers, L. E.; Goldhoorn, P. B.

    1990-01-01

    A rapid high-resolution high pressure liquid chromatographic method was developed for assaying pilocarpine. Pilocarpine in ophthalmic solutions decomposes fairly rapidly to give isopilocarpine, pilocarpic acid and isopilocarpic acid. The quality of an ophthalmic solution can be assessed by assaying

  9. High Performance Liquid Chromatographic Analysis of Phytoplankton Pigments Using a C16-Amide Column

    Science.gov (United States)

    A reverse-phase high performance liquid chromatographic (RP-HPLC) method was developed to analyze in a single run, most polar and non-polar chlorophylls and carotenoids from marine phytoplankton. The method is based on a RP-C16-Amide column and a ternary gradient system consistin...

  10. The combination of the liquid chromatograph with the nuclear magnetic resonance spectrometer

    International Nuclear Information System (INIS)

    Scott, R.P.W.

    1986-01-01

    The association of the liquid chromatograph with the NMR spectrometer would be a very powerful analytical system for the separation and identification of unknown mixtures. There are, however, some serious difficulties involved with the association of these two techniques. The historical development of NMR chromatography is outlined and some problems are discussed. (Auth.)

  11. Determination of suvorexant in human plasma using 96-well liquid-liquid extraction and HPLC with tandem mass spectrometric detection.

    Science.gov (United States)

    Breidinger, S A; Simpson, R C; Mangin, E; Woolf, E J

    2015-10-01

    A method, using liquid chromatography with tandem mass spectrometric detection (LC-MS/MS), was developed for the determination of suvorexant (MK-4305, Belsomra(®)), a selective dual orexin receptor antagonist for the treatment insomnia, in human plasma over the concentration range of 1-1000ng/mL. Stable isotope labeled (13)C(2)H3-suvorexant was used as an internal standard. The sample preparation procedure utilized liquid-liquid extraction, in the 96-well format, of a 100μL plasma sample with methyl t-butyl ether. The compounds were chromatographed under isocratic conditions on a Waters dC18 (50×2.1mm, 3μm) column with a mobile phase consisting of 30/70 (v/v %) 10mM ammonium formate, pH3/acetonitrile at a flow rate of 0.3mL/min. Multiple reaction monitoring of the precursor-to-product ion pairs for suvorexant (m/z 451→186) and (13)C(2)H3-suvorexant (m/z 455→190) on an Applied Biosystems API 4000 tandem mass spectrometer was used for quantitation. Intraday assay precision, assessed in six different lots of control plasma, was within 10% CV at all concentrations, while assay accuracy ranged from 95.6 to 105.0% of nominal. Quality control (QC) samples in plasma were stored at -20°C. Initial within day analysis of QCs after one freeze-thaw cycle showed accuracy within 9.5% of nominal with precision (CV) of 6.7% or less. The plasma QC samples were demonstrated to be stable for up to 25 months at -20°C. The method described has been used to support clinical studies during Phase I through III of clinical development. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Liquid chromatographic and spectrophotometric methods for the determination of erythromycin stearate and trimethoprim in tablets

    OpenAIRE

    Hassib, Sonia T.; Farag, Awatef E.; Elkady, Ehab F.

    2011-01-01

    Simple, accurate and precise reversed-phase liquid chromatographic (LC) and spectrophotometric methods have been developed and validated for the determination of erythromycin stearate (ERS) and trimethoprim (TMP) in mixture. In LC method, chromatographic separation was achieved on a Symmetry® Waters C18 column (150 × 4.6 mm, 5 μm) based on isocratic elution using a mobile phase consisting of potassium dihydrogen phosphate buffer pH (9):acetonitrile:water (25:100:50, v/v/v) at a flow rate of 1...

  13. Acrylamide analysis in food by liquid chromatographic and gas chromatographic methods.

    Science.gov (United States)

    Elbashir, Abdalla A; Omar, Mei M Ali; Ibrahim, Wan Aini Wan; Schmitz, Oliver J; Aboul-Enein, Hassan Y

    2014-01-01

    Acrylamide (AA) is a compound classified as carcinogenic to humans by the International Agency for Research on Cancer. It was first discovered to be present in certain heated processed food by the Swedish National Food Administration (SNFA) and University of Stockholm in early 2002. The major pathway for AA formation in food is the Maillard reaction between reducing sugar and the amino acid asparagine at high temperature. Since the discovery of AA's presence in food, many analytical methods have been developed for determination of AA contents in different food matrices. Also, several studies have been conducted to develop extraction procedures for AA from difficult food matrices. AA is a small, highly polar molecule, which makes its extraction and analysis challenging. Many articles and reviews have been published dealing with AA in food. The aim of the review is to discuss AA formation in food, the factors affecting AA formation and removal, AA exposure assessment, AA extraction and cleanup from food samples, and analytical methods used in AA determination, such as high-performance liquid chromatography (HPLC) and gas chromatography (GC). Special attention is given to sample extraction and cleanup procedures and analytical techniques used for AA determination.

  14. Sensitive liquid chromatography-tandem mass spectrometry method for quantification of hydrochlorothiazide in human plasma.

    Science.gov (United States)

    Ramakrishna, N V S; Vishwottam, K N; Manoj, S; Koteshwara, M; Wishu, S; Varma, D P

    2005-12-01

    A simple, rapid, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed and validated for quantification of hydrochlorothiazide (I), a common diuretic and anti-hypertensive agent. The analyte and internal standard, tamsulosin (II) were extracted by liquid-liquid extraction with diethyl ether-dichloromethane (70:30, v/v) using a Glas-Col Multi-Pulse Vortexer. The chromatographic separation was performed on a reversed-phase column (Waters symmetry C18) with a mobile phase of 10 mm ammonium acetate-methanol (15:85, v/v). The protonated analyte was quantitated in negative ionization by multiple reaction monitoring with a mass spectrometer. The mass transitions m/z 296.1 solidus in circle 205.0 and m/z 407.2 solidus in circle 184.9 were used to measure I and II, respectively. The assay exhibited a linear dynamic range of 0.5-200 ng/mL for hydrochlorothiazide in human plasma. The lower limit of quantitation was 500 pg/mL, with a relative standard deviation of less than 9%. Acceptable precision and accuracy were obtained for concentrations over the standard curve ranges. A run time of 2.5 min for each sample made it possible to analyze a throughput of more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies. (c) 2005 John Wiley & Sons, Ltd.

  15. Liquid chromatography tandem mass spectrometry method for simultaneous determination of metoprolol tartrate and ramipril in human plasma.

    Science.gov (United States)

    Gowda, K Veeran; Mandal, Uttam; Senthamil Selvan, P; Sam Solomon, W D; Ghosh, Animesh; Sarkar, Amlan Kanti; Agarwal, Sangita; Nageswar Rao, T; Pal, Tapan Kumar

    2007-10-15

    A simple, rapid, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed and validated for quantification of metoprolol tartrate (MT) and ramipril, in human plasma. Both the drugs were extracted by liquid-liquid extraction with diethyl ether-dichloromethane (70:30, v/v). The chromatographic separation was performed on a reversed-phase C8 column with a mobile phase of 10 mM ammonium formate-methanol (3:97, v/v). The protonated analyte was quantitated in positive ionization by multiple reaction monitoring with a mass spectrometer. The method was validated over the concentration range of 5-500 ng/ml for metoprolol and ramipril in human plasma. The precursor to product ion transitions of m/z 268.0-103.10 and m/z 417.20-117.20 were used to measure metoprolol and ramipril, respectively.

  16. Liquid-liquid extraction of strongly protein bound BMS-299897 from human plasma and cerebrospinal fluid, followed by high-performance liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Xue, Y J; Pursley, Janice; Arnold, Mark

    2007-04-11

    BMS-299897 is a gamma-secretase inhibitor that is being developed for the treatment of Alzheimer's disease. Liquid-liquid extraction (LLE), chromatographic/tandem mass spectrometry (LC/MS/MS) methods have been developed and validated for the quantitation of BMS-299897 in human plasma and cerebrospinal fluid (CSF). Both methods utilized (13)C6-BMS-299897, the stable label isotope analog, as the internal standard. For the human plasma extraction method, two incubation steps were required after the addition of 5 mM ammonium acetate and the internal standard in acetonitrile to release the analyte bound to proteins prior to LLE with toluene. For the human CSF extraction method, after the addition of 0.5 N HCl and the internal standard, CSF samples were extracted with toluene and no incubation was required. The organic layers obtained from both extraction methods were removed and evaporated to dryness. The residues were reconstituted and injected into the LC/MS/MS system. Chromatographic separation was achieved isocratically on a MetaChem C18 Hypersil BDS column (2.0 mm x 50 mm, 3 microm). The mobile phase contained 10 mM ammonium acetate pH 5 and acetonitrile. Detection was by negative ion electrospray tandem mass spectrometry. The standard curves ranged from 1 to 1000 ng/ml for human plasma and 0.25-100 ng/ml for human CSF. Both standard curves were fitted to a 1/x weighted quadratic regression model. For both methods, the intra-assay precision was within 8.2% CV, the inter-assay precision was within 5.4% CV, and assay accuracy was within +/-7.4% of the nominal values. The validation and sample analysis results demonstrated that both methods had acceptable precision and accuracy across the calibration ranges.

  17. Liquid to liquid extraction and liquid chromatography-tandem mass spectrometry determination of hainanmycin in feed.

    Science.gov (United States)

    Wang, Ze Ping; Shen, Jian Zhong; Linhardt, Robert J; Jiang, Hui; Cheng, Lin Li

    2017-03-01

    Hainanmycin is a new veterinary polyether antibiotic and has few sensitive analytical method in present days. In this study, a liquid chromatography-tandem mass spectrometry (LC-MS/MS) relying on multiple reaction monitoring (MRM) detection was developed for analysis of hainanmycin in animal feed. Feed samples were extracted with ethyl acetate and purified by two steps of liquid-liquid extraction (LLE) to get rid of water solvable matrix and lipids one by one. The final simple was analyzed by LC-MS/MS. The LC mobile phase was composed of 0.1% aqueous formic acid and 0.1% formic acidified acetonitrile by gradient elution. Average recoveries ranged from 74.22% to 87.85%, as determined by spiking with 2.0 (LOQ) ∼2500μgkg -1 of hainanmycin. The inter-day and intra-day coefficient of variation was 9.21% to 11.77% and 7.67% to 13.49%, respectively. The limit of detection (LOD) and the limit of quantitation (LOQ) were 0.36μgkg -1 and 2.0μgkg -1 , respectively. Copyright © 2016. Published by Elsevier B.V.

  18. High-performance liquid chromatographic radioenzymatic assay for plasma catecyholamines

    International Nuclear Information System (INIS)

    Klaniecki, T.S.; Corder, C.N.; McDonald, R.H. Jr.; Feldman, J.A.

    1977-01-01

    A new assay method for plasma catecholamimes (CA) requiring only 50 μl has been developed, which uses high performance liquid chromatography (HPLC). The norepinephrine (NE), dopamine (D), and epinephrine (E) compounds found in plasma are radioactively o-methylated with S-[methyl- 3 H]-adenosyl-L-methionine ( 3 H-SAM) 3 H-SAM by the reaction of catechol-o-methyl transferase (COMT). The reaction is terminated and a standard mixture of nonradioactive o-methylated analogues of NE, D, and E is added to act as a carrier. Following separation by HPLC, the D,L-normetanephrine (NMN), 3-methoxy-4-hydroxyphenylethyl-amine or 3-methoxytyramine (3-MOT), and metanephrine (MN) radioactive peaks are collected which represent NE, D, and E, respectively. Then MNM and MN are oxidized to vanillin, and 3-MOT is acetylated. The products are subsequently separated by solvent extraction. This is necessary in order to avoid high radioactive blanks and to allow quantitation of the radioactivity by liquid scintillation spectrometry. The mean supine levels of NE, D, and E in normal subjects were respectively 182, 33, and 87 pg/ml of plasma. Similar assays on patients with pheochromocytoma revealed 797, 80, and 470 pg/ml

  19. Liquid chromatographic separation of terpenoid pigments in foods and food products.

    Science.gov (United States)

    Cserháti, T; Forgács, E

    2001-11-30

    The newest achievements in the use of various liquid chromatographic techniques such as adsorption and reversed-phase thin-layer chromatography and HPLC employed for the separation and quantitative determination of terpenoid-based color substances in foods and food products are reviewed. The techniques applied for the analysis of individual pigments and pigments classes are surveyed and critically evaluated. Future trends in the separation and identification of pigments in foods and food products are delineated.

  20. High-performance liquid-chromatographic separation of subcomponents of antimycin-A

    Science.gov (United States)

    Abidi, S.L.

    1988-01-01

    Using a reversed-phase high-performance liquid chromatographic (HPLC) technique, a mixture of antimycins A was separated into eight hitherto unreported subcomponents, Ala, Alb, A2a, A2b, A3a, A3b, A4a, and A4b. Although a base-line resolution of the known four major antimycins Al, A2, A3, and A4 was readily achieved with mobile phases containing acetate buffers, the separation of the new antibiotic subcomponents was highly sensitive to variation in mobile phase conditions. The type and composition of organic modifiers, the nature of buffer salts, and the concentration of added electrolytes had profound effects on capacity factors, separation factors, and peak resolution values. Of the numerous chromatographic systems examined, a mobile phase consisting of methanol-water (70:30) and 0.005 M tetrabutylammonium phosphate at pH 3.0 yielded the most satisfactory results for the separation of the subcomponents. Reversed-phase gradient HPLC separation of the dansylated or methylated antibiotic compounds produced superior chromatographic characteristics and the presence of added electrolytes was not a critical factor for achieving separation. Differences in the chromatographic outcome between homologous and structural isomers were interpretated based on a differential solvophobic interaction rationale. Preparative reversed-phase HPLC under optimal conditions enabled isolation of pure samples of the methylated antimycin subcomponents for use in structural studies.

  1. Determination of itopride in human plasma by liquid chromatography coupled to tandem mass spectrometric detection: application to a bioequivalence study.

    Science.gov (United States)

    Lee, Heon-Woo; Seo, Ji-Hyung; Choi, Seung-Ki; Lee, Kyung-Tae

    2007-01-30

    A simple method using a one-step liquid-liquid extraction (LLE) with butyl acetate followed by high-performance liquid chromatography (HPLC) with positive ion electrospray ionization tandem mass spectrometric (ESI-MS/MS) detection was developed for the determination of itopride in human plasma, using sulpiride as an internal standard (IS). Acquisition was performed in multiple reaction monitoring (MRM) mode, by monitoring the transitions: m/z 359.5>166.1 for itopride and m/z 342.3>111.6 for IS, respectively. Analytes were chromatographed on an YMC C18 reverse-phase chromatographic column by isocratic elution with 1 mM ammonium acetate buffer-methanol (20: 80, v/v; pH 4.0 adjusted with acetic acid). Results were linear (r2=0.9999) over the studied range (0.5-1000 ng mL(-1)) with a total analysis time per run of 2 min for LC-MS/MS. The developed method was validated and successfully applied to bioequivalence studies of itopride hydrochloride in healthy male volunteers.

  2. Liquid chromatographic determination of saccharin in beverages and desserts: complementary collaborative study.

    Science.gov (United States)

    Sjöberg, A M

    1988-01-01

    A complementary collaborative study was conducted on a liquid chromatographic method for determination of saccharin in accordance with the latest international recommendations. One industrial and 6 official food control laboratories analyzed 3 samples of a juice, a soft drink, and a dessert at concentration levels of 26-90 mg/L, 33-73 mg/L, and 56-147 mg/kg, respectively. Blind duplicates and a blank were supplied for each type of material at each concentration level. The beverage was chromatographed directly and the dessert was extracted with ethanol before chromatography. Average recoveries were 95-107%. The reproducibility relative standard deviations were 6.4-7.3% for the juice, 9.2-20.6% for the soft drink, and 13.4-16.2% for the dessert. The outlier percentage was 14.3%. The results were compared with those of an earlier collaborative study by Nordic laboratories and with general collaborative results obtained by AOAC.

  3. Gas-liquid chromatographic determination of resmethrin in corn, cornmeal, flour, and wheat.

    Science.gov (United States)

    Simonaitis, R A; Cail, R S

    1975-09-01

    A gas-liquid chromatographic (GLC) method was developed for the determination of residues of resmethrin ((5-benzyl-3-furyl)methyl cis-trans-(+/-)-2,2-dimethyl-3-(2-methylpropenyl)-cyclopropanecarboxylate) in corn, cornmeal, flour, and wheat. The commodity, fortified with resmethrin, was extracted by tumbling with pentane and transferred to acetonitrile, the fat was partitioned off, and the sample was chromatographed with 3% ethyl acetate in pentane on Florisil containing 0.5% water. The resmethrin residue was determined by GLC with a flame ionization detector. The results were compared with known standards that had undergone the same cleanup procedures. The method was sensitive to concentrations of resmethrin to 0.2 ppm, recoveries averaged 83%, and reproducibility was good.

  4. Stereospecific high-performance liquid chromatographic assay of sotalol in plasma.

    Science.gov (United States)

    Carr, R A; Foster, R T; Bhanji, N H

    1991-09-01

    A convenient high-performance liquid chromatographic (HPLC) assay was developed for determination of sotalol (STL) enantiomers in plasma. Following addition of the internal standard (IS; racemic atenolol), enantiomers of STL and IS were extracted using ethyl acetate. After evaporation of the organic layer, samples were derivatized with a solution of S-(+)-1-(1-naphthyl)ethyl isocyanate (NEIC). The resulting diastereomers were chromatographed with normal-phase HPLC with chloroform:hexane:methanol [65:33:2 (v/v)] as the mobile phase at a flow rate of 2 ml/min. The fluorescence detection wavelength was set at 220 nm for excitation with no emission filter. The suitability of the assay for pharmacokinetic studies was determined by measuring STL enantiomers in the plasma of a healthy subject after administration of a single 160-mg oral, racemic dose of STL.

  5. Determination of flomoxef in human plasma by liquid chromatography/electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Kravtsova, Oxana Yu; Paramonov, Sergey A; Vasilevich, Natalya I; Kazyulkin, Denis N; Vlasova, Ekaterina; Engsig, Michael

    2013-12-01

    A specific, sensitive, rapid and reproducible method for the determination of flomoxef in human plasma using high-performance liquid chromatography-tandem mass spectrometry was developed and validated. Flomoxef was detected using an electrospay ionization method operated in negative-ion mode. Chromatographic separation was performed in gradient elution mode on a Luna® C18(2) column (3 μM, 20 × 4.0 mm) at a flow rate of 1 mL/min and runtime 3.5 min. The mobile phase consisted of acetonitrile and water containing 0.1% formic acid as additive. Extraction of flomoxef from plasma and precipitation of plasma proteins was performed with acetonitrile with an absolute recovery of 86.4 ± 1.6%. The calibration curve was linear with a correlation coefficient of 0.999 over the concentration range 10-5000 ng/mL and the lower limit of quantification was 10 ng/mL. The intra- and inter-day precisions were flomoxef revealed that it could be successfully analyzed at 4 ºС over 24 h, but it was unstable in solutions at room temperature during short-term storage (4 h) and several freeze-thaw cycles. Copyright © 2013 John Wiley & Sons, Ltd.

  6. Simultaneous determination of ramipril, ramiprilat and telmisartan in human plasma using liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Gupta, V K; Jain, Rajeev; Lukram, Ojitkumar; Agarwal, Shilpi; Dwivedi, Ashish

    2011-01-15

    A rapid and sensitive liquid chromatography tandem mass spectrometry method has been developed and validated for the simultaneous determination of ramipril, ramiprilat and telmisartan in human plasma. The solid-phase extraction technique was used for the extraction of ramipril, ramiprilat and telmisartan from human plasma. Trandolaprilat and hydrochlorothiazide were used as the internal standards (ISs). Chromatography was performed on a Hypurity C18, 5 μm, 50 mm × 4.6mm column, with the mobile phase consisting of ammonium acetate and acetonitrile (in a 20:80 ratio), followed by detection using mass spectrometry. The method involves a simple reversed isocratic chromatography condition and mass spectrometry detection, which enables detection at sub-nanogram levels. The method was validated and the lower limit of quantification for ramipril, ramiprilat and telmisartan was found to be 0.1 ng mL(-1), 0.1 ng mL(-1) and 2 ng mL(-1), respectively. The mean recovery for ramipril, ramiprilat and telmisartan ranged from 90.1 to 104.1%. This method increased the sensitivity and selectivity; resulting in high-throughput analysis of ramipril, ramiprilat and telmisartan using two different ISs in a single experiment for bioequivalence studies, with a chromatographic run time of 1.5 min only. Copyright © 2010 Elsevier B.V. All rights reserved.

  7. Determination and pharmacokinetic studies of arecoline in dog plasma by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Li, Bing; Zhou, Xu-Zheng; Li, Jian-Yong; Yang, Ya-Jun; Niu, Jian-Rong; Wei, Xiao-Juan; Liu, Xi-Wang; Li, Jin-Shan; Zhang, Ji-Yu

    2014-10-15

    A rapid and sensitive high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the determination of arecoline concentration in dog plasma. Plasma sample was prepared by protein precipitation using n-hexane (containing 1% isoamyl alcohol) with β-pinene as an internal standard. Chromatographic separation was achieved on an Agilent C18 column (4.6×75mm, 3.5μm) using methanol: 5mM ammonium acetate as the mobile phase with isocratic elution. Mass detection was carried out using positive electrospray ionization in multiple reaction monitoring mode. The calibration curve for arecoline was linear over a concentration range of 2-500ng/mL. The intra-day and inter-day accuracy and precision were within the acceptable limits of ±10% at all concentrations. In summary, the LC-MS/MS method described herein was fully validated and successfully applied to the pharmacokinetic study of arecoline hydrobromide tablets in dogs after oral administration. Copyright © 2014. Published by Elsevier B.V.

  8. Liquid chromatography-tandem mass spectrometry for analysis of intestinal permeability of loperamide in physiological buffer.

    Directory of Open Access Journals (Sweden)

    Miriam S Rubelt

    Full Text Available Analysis of in vitro samples with high salt concentrations represents a major challenge for fast and specific quantification with liquid chromatography-tandem mass spectrometry (LC-MS/MS. To investigate the intestinal permeability of opioids in vitro employing the Ussing chamber technique, we developed and validated a fast, sensitive and selective method based on LC-MS/MS for the determination of loperamide in HEPES-buffered Ringer's solution. Chromatographic separation was achieved with an Atlantis dC18 column, 2.1 mm×20 mm, 3 µm particle size and a gradient consisting of methanol/0.1% formic acid and ammonium acetate. The flow rate was 0.7 ml/min, and the total run time was 3 min. For quantification, two mass transitions for loperamide and a deuterated internal standard (methadone-d(3 were used. The lower limit of loperamide quantification was 0.2 ng/ml. This new LC-MS/MS method can be used for the detection of loperamide in any experimental setup using HEPES-buffered Ringer's solution as a matrix compound.

  9. Development and validation of micellar liquid chromatographic methods for the determination of antibiotics in different matrixes.

    Science.gov (United States)

    Rambla-Alegre, Maria; Esteve-Romero, Josep; Carda-Broch, Samuel

    2011-01-01

    Antibiotics are the most important bioactive and chemotherapeutic compounds to be produced by microbiological synthesis, and they have proved their worth in a variety of fields, such as medicinal chemistry, agriculture, and the food industry. Interest in antibiotics has grown in parallel with an increasingly high degree of productivity in the field of analytical applications. Therefore, it is necessary to develop chromatographic procedures capable of determining various drugs simultaneously in the shortest possible time. Micellar liquid chromatography (MLC) is an RP-HPLC technique that offers advantages over conventional HPLC as far as sample preparation, selectivity, and versatility are concerned. Its main advantage is that samples can be injected directly into the chromatographic system with no previous preparation step. This paper mainly focuses on the results of the authors' own recent research and reports the chromatographic conditions for determination of various antibiotics (penicillins, quinolones, and sulfonamides) in different matrixes (pharmaceuticals, biological fluids, and food). The work of other authors on MLC-based antibiotic determination has been included.

  10. A liquid chromatographic method for determination of theophylline in serum and capillary blood--a comparison.

    Science.gov (United States)

    Gartzke, J; Jäger, H; Vins, I

    1991-01-01

    A simple, fast and reliable liquid chromatographic method for the determination of theophylline in serum and capillary blood after a solid phase extraction is described for therapeutic drug monitoring. The employment of capillary blood permits the determination of an individual drug profile and other pharmacokinetic studies in neonates and infants. There were no differences in venous- and capillary-blood levels but these values compared poorly with those in serum. An adjustment of the results by correction of the different volumes of serum and blood by haematocrit was unsuccessful. Differences in the binding of theophylline to erythrocytes could be an explanation for the differences in serum at blood levels of theophylline.

  11. Sorption and chromatographic techniques for processing liquid waste of nuclear fuel cycle

    International Nuclear Information System (INIS)

    Gelis, V.M.; Milyutin, V.V.; Chuveleva, E.A.; Maslova, G.B.; Kudryavtseva, S.P.; Firsova, L.A.; Kozlitin, E.A.

    2000-01-01

    In the spent nuclear fuel processing procedures the significant quantity of high level liquid waste containing long-lived high toxic radionuclides of cesium, strontium, promethium, americium, curium, etc. is generated. Separation of those radionuclides from the waste not merely simplifies the further safe waste handling but also reduces the waste processing operation costs due to the market value of certain individual radionuclide preparations. Recovery and separation of high grade pure long-lived radionuclide preparations is frequently performed by means of chromatographic techniques. (authors)

  12. High-pressure liquid chromatographic determination of chlorphenesin carbamate and the beta-isomeric carbamate.

    Science.gov (United States)

    Beyer, W F

    1976-12-01

    A high-pressure liquid chromatographic assay was developed for the determination of chlorphenesin carbamate and its beta-isomeric carbamate. A single 4-mm i.d. X 30-cm column, prepacked with 10 micrometer fully porous silica gel particles, is used with 3% methanol in 50% water-saturated butyl chloride as the mobile phase. The procedure separates chlorphenesin carbamate from several possible impurities in addition to the beta-isomeric carbamate. The assay was applied to bulk drug and compressed tablets. The relative standard deviations for the assays of chlorphenesin carbamate and the beta-isomer are approximately 1 and 2%, respectively.

  13. High-pressure liquid chromatographic analysis of pramoxine hydrochloride in high lipoid aerosol foam dosage form.

    Science.gov (United States)

    Weinberger, R; Mann, B; Posluszny, J

    1980-04-01

    A rapid and quantitative method for the determination of pramoxine hydrochloride by high-pressure liquid chromatography is presented. The drug is extracted as the salt from a preparation with a high lipoid composition by partitioning it to the aqueous phase of an ether-methanol-water-acetic acid system. The extract is chromatographed on an octadecylsilane bonded packing with a methanol-water-acetic acid-methanesulfonic acid mobile phase. The time required for each separation is approximately 6 min. Analytical recoveries of 100.4 +/- 1.5% were obtained.

  14. Determination of nifedipine in dog plasma by high-performance liquid chromatography with tandem mass spectrometric detection.

    Science.gov (United States)

    Pan, Xigui; Zhou, Shunchang; Fu, Qinqin; Hu, Xianming; Wu, Jianhong

    2014-07-01

    Nifedipine is a dihydropyridine calcium channel blocker used widely in the management of hypertension and other cardiovascular disorders. In this work, a simple, rapid and sensitive liquid chromatography/tandem mass spectrometry method was developed and validated to determine nifedipine in dog plasma using nimodipine as the internal standard. Chromatographic separation was carried out on a C₈ column. The mobile phase consisted of a mixture of acetonitrile, water and formic acid (60:40:0.2, v/v/v) at a flow rate of 0.5 mL/min. Detection was performed on a triple quadrupole tandem mass spectrometer in selected reaction monitoring mode via an atmospheric pressure chemical ionization source. The method has a lower limit of quantification of 0.20 ng/mL with consumption of plasma as low as 0.05 mL. The linear calibration curves were obtained in the concentration range of 0.20-50.0 ng/mL (r = 0.9948). The recoveries of the liquid extraction method were 74.5-84.1%. Intra-day and inter-day precisions were 4.1-8.8 and 6.7-7.4%, respectively. The quantification was not interfered with by other plasma components and the method was applied to determine nifedipine in plasma after a single oral administration of two controlled-release nifedipine tablets to beagle dogs. Copyright © 2013 John Wiley & Sons, Ltd.

  15. FAST DETECTION OF ACETYLSALICYLIC ACID BY LIQUID CHROMATOGRAPHY TANDEM MASS SPECTROMETRY(LC-MSMS)

    OpenAIRE

    Abusoglu, Sedat; Unlu, Ali; Sivrikaya, Abdullah

    2018-01-01

    ObjectivesAcetylsalicylic acid (ASA) is themost widely used as an analgesic, anti-inflammatory and antipyretic drug, andalso used to inhibit cyclooxygenase dependent platelet aggregation.   The aimof this study was to develop a simple, fast and accurate tandem mass method fordetermination and quantification of ASA.  MethodsChromatographic seperation was performedusing an Shimadzu LC-20-AD (Kyoto, Japan) coupledwith a ABSCIEX API 3200 triple quadrupole massspectromete...

  16. Total cholesterol in serum determined by isotope dilution/mass spectrometry, with liquid-chromatographic separation

    International Nuclear Information System (INIS)

    Takatsu, Akiko; Nishi, Sueo

    1988-01-01

    We describe an accurate, precise method for determination of total serum cholesterol by isotope dilution/mass spectrometry (IDMS) with liquid chromatographic separation. After adding [3,4- 13 C] cholesterol to serum and hydrolyzing the cholesterol esters, we extract the total cholesterol. High-performance liquid chromatography (HPLC) is used to separate the extracted cholesterol for measurement by electron-impact mass spectrometry with use of a direct-insertion device. To evaluate the specificity and the accuracy of this method, we also studied the conventional IDMS method, which involves converting cholesterol to the trimethylsilyl ether and assay by gas chromatography-mass spectrometry with use of a capillary column. The coefficient of variation for the HPLC method was a little larger than for the conventional method, but mean values by each method agreed within 1% for all sera tested. (author)

  17. TANDEM

    Data.gov (United States)

    Federal Laboratory Consortium — The Tandem Van de Graaff facility provides researchers with beams of more than 40 different types of ions - atoms that have been stripped of their electrons. One of...

  18. Ultra-high performance liquid chromatography tandem high-resolution mass spectrometry study of tricyclazole photodegradation products in water.

    Science.gov (United States)

    Gosetti, Fabio; Chiuminatto, Ugo; Mazzucco, Eleonora; Mastroianni, Rita; Bolfi, Bianca; Marengo, Emilio

    2015-06-01

    This paper reports the study of the photodegradation reactions that tricyclazole can naturally undergo, under the action of sunlight, in aqueous solutions of standard tricyclazole and of the commercial BEAM(TM) formulation. The analyses are carried out by ultra-high performance liquid chromatography technique coupled with high-resolution tandem mass spectrometry. Analysis of both tricyclazole and BEAM(TM) water solutions undergone to hydrolysis does not evidence new chromatographic peaks with respect to the not treated solutions. On the contrary, analysis of the same samples subjected to sunlight irradiation shows a decreased intensity of tricyclazole signal and the presence of new chromatographic peaks. Two photodegradation products of tricyclazole have been identified, one of which has been also quantified, being the commercial standard available. The pattern is similar for the solutions of the standard fungicide and of the BEAM(TM) formulation. The results obtained from eco-toxicological tests show that toxicity of tricyclazole standard solutions is greater than that of the irradiated ones, whereas toxicity levels of all the BEAM(TM) solutions investigated (non-irradiated, irradiated, and hydrolyzed) are comparable and lower than those shown by tricyclazole standard solutions. Experiments performed in paddy water solution show that there is no difference in the degradation products formed.

  19. Liquid chromatographic and spectrophotometric methods for the determination of erythromycin stearate and trimethoprim in tablets

    Directory of Open Access Journals (Sweden)

    Sonia T. Hassib

    2011-12-01

    Full Text Available Simple, accurate and precise reversed-phase liquid chromatographic (LC and spectrophotometric methods have been developed and validated for the determination of erythromycin stearate (ERS and trimethoprim (TMP in mixture. In LC method, chromatographic separation was achieved on a Symmetry® Waters C18 column (150 × 4.6 mm, 5 μm based on isocratic elution using a mobile phase consisting of potassium dihydrogen phosphate buffer pH (9:acetonitrile:water (25:100:50, v/v/v at a flow rate of 1.6 ml min−1 with UV detection at 210 nm for ERS and 280 nm for TMP. Besides, two spectrophotometric methods were applied after reaction with perchloric acid (12 M which gives a colored product with ERS. Then, the spectral interference between the colored product of ERS and TMP was resolved by either ratio spectra derivative spectrophotometry in the first spectrophotometric method or chemometric techniques, namely classical least-squares (CLS, principal component regression (PCR and partial least-squares regression (PLS in the second spectrophotometric method. The results were statistically compared using one-way analysis of variance (ANOVA. The methods developed were satisfactorily applied to the analysis of the pharmaceutical preparation containing the two drugs and proved to be specific and accurate for the quality control of the cited drugs in pharmaceutical dosage forms.

  20. Liquid chromatographic determination with fluorescence detection of B6 vitamers and riboflavin in milk and pharmaceuticals

    International Nuclear Information System (INIS)

    Gatti, R.; Gioia, M.G.

    2005-01-01

    A simple, reliable and selective high performance liquid chromatographic method with fluorescence detection at different programmed wavelengths has been developed for the simultaneous analysis of B 6 vitamers (pyridoxal 5'-phosphate, 4-pyridoxic acid, pyridoxal, pyridoxine and pyridoxamine) and Vitamin B 2 in commercial vitaminized milk and in woman milk. The chromatographic separations were performed on a reversed phase octyl column by using a mobile phase consisting of sodium pentanesulfonate in 1% acetic acid-methanol-tetrahydrofuran under gradient elution conditions. The fluorescence intensity of pyridoxal 5'-phosphate was enhanced by post-column photochemical conversion, giving significantly different fluorescence spectra by a on-line photoreactor switched OFF and ON under irradiation at 254 nm. In addition, a simple and rapid method in isocratic conditions without the need of photochemical conversion was proposed for the analysis of Vitamin B 6 and Vitamin B 2 in pharmaceuticals. Linearity, precision, recovery, selectivity and sensitivity were found satisfactory for each analysed compound. Quantitation limits ranged from 26 to 240 fmol

  1. A Selective High Performance Liquid Chromatographic Method to Follow the Hydrolytic Degradation of Nicardipine Hydrochloride

    Directory of Open Access Journals (Sweden)

    K. E. Ibrahim

    2010-01-01

    Full Text Available A simple, stability indicating, reverse phase high performance liquid chromatographic method was developed and validated for determination of nicardipine hydrochloride (NC in the presence of its degradation products. The chromatographic separation was performed on Hypersil, BDS-C18, 30 cm × 3.9 mm id, at ambient temperature with UV-detection at 254 nm. A mixture of 20% (v/v aqueous 0.01 M sodium acetate∕acetic acid buffer (pH 4.5 and 80% acetonitrile was used as the mobile phase at a flow rate of 1.5 mL min-1, losartan was used as internal standard. The calibration curve is linear over the concentration range 5-40 μg mL-1, with a regression coefficient of 0.9984 and the % recovery was 99.78±0.17. The method was used to investigate the kinetics of alkaline, acids induced degradation, effect of buffer concentration and temperature. The degradation followed first-order kinetics. The rate constant, half-life time, and activation energy were calculated

  2. Determination of drugs in biological fluids by direct injection of samples for liquid-chromatographic analysis.

    Science.gov (United States)

    Mullett, Wayne M

    2007-03-10

    The analysis of drugs in various biological fluids is an important criterion for the determination of the physiological performance of a drug. After sampling of the biological fluid, the next step in the analytical process is sample preparation. The complexity of biological fluids adds to the challenge of direct determination of the drug by chromatographic analysis, therefore demanding a sample preparation step that is often time-consuming, tedious, and frequently overlooked. However, direct on-line injection methods offer the advantage of reducing sample preparation steps and enabling effective pre-concentration and clean-up of biological fluids. These procedures can be automated and therefore reduce the requirements for handling potentially infectious biomaterial, improve reproducibility, and minimize sample manipulations and potential contamination. The objective of this review is to present an overview of the existing literature with emphasis on advances in automated sample preparation methods for liquid-chromatographic methods. More specifically, this review concentrates on the use of direct injection techniques, such as restricted-access materials, turbulent-flow chromatography and other automated on-line solid-phase extraction (SPE) procedures. It also includes short overviews of emerging automated extraction-phase technologies, such as molecularly imprinted polymers, in-tube solid-phase micro-extraction, and micro-extraction in a packed syringe for a more selective extraction of analytes from complex samples, providing further improvements in the analysis of biological materials. Lastly, the outlook for these methods and potential new applications for these technologies are briefly discussed.

  3. Online liquid chromatography-tandem mass spectrometry cyanide determination in blood.

    Science.gov (United States)

    Lacroix, C; Saussereau, E; Boulanger, F; Goullé, J P

    2011-04-01

    An original liquid chromatography-tandem mass spectrometry (LC-MS-MS) method coupled to online extraction has been developed for cyanide determination in blood. A method involving fluorimetric detection after naphthalene-2,3-dicarboxyaldehyde (NDA) complexation by taurine in the presence of cyanide was previously described. Its performance was limited because of the absence of an internal standard (IS). Using cyanide isotope (13)C(15)N as IS allowed quantification in MS-MS. After the addition of (13)C(15)N, 25 μL of blood were diluted in water and deproteinized with methanol. Following derivatization with NDA and taurine for 10 min at 4°C, 100 μL was injected into the online LC-MS-MS system. An Oasis HLB was used as an extraction column, and a C18 Atlantis was the analytical column. The chromatographic cycle was performed with an ammonium formate (20 mM, pH 2.8) (solvent A) and acetonitrile/solvent A (90:10, v/v) gradient in 6 min. Detection was performed in negative electrospray ionization mode (ESI(-)) with a Quattro Micro. For quantification, transitions of derivatives formed with CN and (13)C(15)N were monitored, respectively, as follows: 299.3/191.3 and 301.3/193.3. The procedure was fully validated, linear from 26 to 2600 ng/mL with limit of detection of 10 ng/mL. This method, using a small blood sample, is not only simple, but also time saving. The specificity and sensitivity of LC-MS-MS coupled to online extraction and using (13)C(15)N as the IS make this method very suitable for cyanide determination in blood and could be useful in forensic toxicology.

  4. Quantification of peramivir in dog plasma by liquid chromatography/tandem mass spectrometry employing precolumn derivatization.

    Science.gov (United States)

    Li, Xin; Li, Ying; Wang, Juan; Wang, Lili; Zhong, Wu; Ruan, Jinxiu; Zhang, Zhenqing

    2014-01-01

    Peramivir is a novel influenza neuraminidase inhibitor used for anti-influenza. In this article, a novel method was developed to determine peramivir in dog plasma using a derivatization treatment step to increase the retention time and enhance the signal intensity. The sample preparation consisted of a protein precipitation extraction followed by derivatization with 10M hydrochloric acid-methanol (10:90, v/v) and determined by liquid chromatography coupled with tandem mass spectrometry. The selected reaction monitoring mode of the positive ion was performed and the precursor to the product ion transitions of m/z 343→284 and m/z 299→152 were used to measure the derivative of peramivir and Ro 64-0802 (internal standard, an active metabolite of oseltamivir). The chromatographic separation was achieved using a ZORBAX RX-C8 (2.0mm×150mm×5μm) analytical column with an isocratic mobile phase composed of acetonitrile-water-formic acid (30:70:0.1, v/v/v, 0.2mL/min). The method was linear over a concentration range of 0.25-250ng/mL. The average intra-day/inter-day precision values were 4.04-8.17% and 3.02-7.08%, respectively, while the average accuracy value was 93.99-106.48%. This method has been successfully applied to the preclinical dog research of peramivir following intragastric administration. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Identification and Quantification of Glucosinolates in Kimchi by Liquid Chromatography-Electrospray Tandem Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Ho Jin Kim

    2017-01-01

    Full Text Available A novel and simple method for detecting five glucosinolates (glucoalyssin, gluconapin, glucobrassicanapin, glucobrassicin, and 4-methoxyglucobrassicin in kimchi was developed using liquid chromatography-electrospray tandem mass spectrometry (LC-MS/MS. The chromatographic peaks of the five glucosinolates were successfully identified by comparing their retention times, mass spectra. The mobile phase was composed of A (acetonitrile and B (water. As for glucosinolate, the relative quantities were found through sinigrin, and five different compounds that have not been previously discovered in kimchi were observed. Monitoring was carried out on the glucosinolate in 20 kimchis distributed in markets, and this study examined the various quality and quantity compositions of the five components. The glucoalyssin content ranged from 0.00 to 7.07 μmol/g of day weight (DW, with an average content of 0.86 μmol/g of DW, whereas the gluconapin content ranged from 0.00 to 5.85 μmol/g of DW, with an average of 1.17 μmol/g of DW. The content of glucobrassicanapin varied between 0.00 and 11.87 μmol/g of DW (average = 3.03 μmol/g of DW, whereas that of glucobrassicin varied between 0.00 and 0.42 μmol/g of DW (average = 0.06 μmol/g of DW. The 4-methoxyglucobrassicin content ranged from 0.12 to 9.36 μmol/g of DW (average = 3.52 μmol/g of DW. A comparison of the contents revealed that, in most cases, the content of 4-methoxyglucobrassicin was the highest.

  6. A simple and selective liquid chromatography- tandem mass spectrometry method for determination of ε-aminocaproic acid in human plasma

    Directory of Open Access Journals (Sweden)

    Ganesh S. Moorthy

    2015-07-01

    Full Text Available Understanding the clinical pharmacology of the antifibrinolytic drug epsilon-aminocaproic acid (EACA is critical for rational drug administration in children. The aim of this study is to develop a reliable assay for the determination of EACA in human plasma. We describe a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS assay for EACA in human plasma. Sample preparation involved plasma dilution (1:2040, followed by reversed-phase chromatographic separation and selective detection using tandem mass spectrometry. EACA had a linear range of 1 - 250 μg/mL. The intraday precision based on the standard deviation of replicates of quality control samples ranged from 4.7 to 10.4% and the accuracy ranged from 92-106%. The interday precision ranged from 4.6 to 9.8% and the accuracy ranged from 95-103%. Stability studies showed that EACA was stable during the conditions for sample preparation and storage. The described method is robust and successfully employed for clinical studies of EACA in children

  7. Rapid Determination of Imatinib in Human Plasma by Liquid Chromatography-Tandem Mass Spectrometry: Application to a Pharmacokinetic Study

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Jeong Soo; Cho, Eun Gi; Huh, Wooseong; Ko, Jaewook; Jung, Jin Ah; Lee, Sooyoun [Samsung Medical Center, Seoul (Korea, Republic of)

    2013-08-15

    A simple, fast and robust analytical method was developed to determine imatinib in human plasma using liquid chromatography-tandem mass spectrometry with electrospray ionization in the positive ion mode. Imatinib and labeled internal standard were extracted from plasma with a simple protein precipitation. The chromatographic separation was performed using an isocratic elution of mobile phase involving 5.0 mM ammonium formate in water -5.0 mM ammonium formate in methanol (30:70, v/v) over 3.0 min on reversed-stationary phase. The detection was performed using a triple-quadrupole tandem mass spectrometer in multiple-reaction monitoring mode. The developed method was validated with lower limit of quantification of 10 ng/mL. The calibration curve was linear over 10-2000 ng/mL (R{sup 2} > 0.99). The method validation parameters met the acceptance criteria. The spiked samples and standard solutions were stable under conditions for storage and handling. The reliable method was successfully applied to real sample analyses and thus a pharmacokinetic study in 27 healthy Korean male volunteers.

  8. [Simultaneous determination of 16 flavonoids in the ginkgo dietary supplement tea by high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Jiang, Yalan; Huang, Fang; Wu, Fuhai; Wu, Huiqin; Huang, Xiaolan; Deng, Xin

    2015-10-01

    A method for the determination of 16 functional components of ginkgo dietary supplement tea such as catechin, vitexin, puerarin, isoflavoues aglycone, silymarin, quercetin, luteolin, apigenin, naringenin, hesperitin dihydrochalcone, kaempferol, hesperitin, isorhamnetin, baicalein, nobiletin and tangeretin by high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was proposed. The conditions of chromatography and mass spectrometry were optimized. The 16 flavonoids were separated on a C18 chromatographic column with acetonitrile and water (additional 0.1% formic acid) as mobile phases under gradient elution at a flow rate of 0.25 mL/min. The determination was conducted by tandem mass spectrometry in positive ESI mode under multiple reaction monitoring (MRM) mode. Good linearities for all the compounds, with correlation coefficients over 0.996, were acquired. The recoveries were in the range of 70.9% to 100.0% (n = 6), while the relative standard deviations (RSDs) were less than 10%. The results showed that the nine flavonoids, which were kaempferol, quercetin, hesperitin, vitexin, luteolin, catechin, apigenin, naringenin and isorhamnetin, were higher in contents among the 16 flavonoids in real samples, and they constituted up to 99.6% of the total flavonoids. The contents of these nine flavonoids can be considered as the quality control index of the ginkgo dietary supplement tea. The method proved to be rapid, selective, sensitive and stable, and it can be applied to control the quality of the ginkgo dietary supplement tea.

  9. Optimization of chromatographic conditions for determination of aflatoxin B1, B2, G1 and G2 by using liquid chromatography-mass Spectrometry

    Science.gov (United States)

    Ramadhaningtyas, Dillani Putri; Aryana, Nurhani; Aristiawan, Yosi; Styarini, Dyah

    2017-11-01

    The optimization of instrument condition and chromatographic separation for analysis of aflatoxin B1, B2, G1 and G2 using liquid chromatography tandem with mass spectrometer detector was conducted in the aim to provide more accurate and reliable analysis results. The aflatoxin known to be serious threat for human health as it is classified as the carcinogenic compounds. The aflatoxin B1, B2, G1 and G2 were selected due to its extensive contamination in various agricultural commodities. The best chromatographic separation was obtained using C-18 column with gradient elution of solvent 5 mM ammonium acetate and 0.1% formic acid in methanol at 7 minutes runtime analysis. The linearity of the detector showed satisfied results as the coefficient determination found to be 0.9994, 0.9996, 0.9998 and 0.9987 for aflatoxin B1, G1, B2, and G2 respectively in the range concentration from 1 to 20 ng/g. The quantifier ion selected for the aflatoxin B1, B2, G1 and G2 was m/z 285.1, 259, 243 and 313 respectively. The instrument precision at these quantifier ions also showed satisfied result with %RSD was around 3.4 to 6.8%. The optimized method present in this study can be used for further sample analysis.

  10. Inductively coupled plasma emission spectrometric detection of simulated high performance liquid chromatographic peaks

    International Nuclear Information System (INIS)

    Fraley, D.M.; Yates, D.; Manahan, S.E.

    1979-01-01

    Because of its multielement capability, element-specificity, and low detection limits, inductively coupled plasma optical emission spectrometry (ICP) is a very promising technique for the detection of specific elemental species separated by high performance liquid chromatography (HPLC). This paper evaluated ICP as a detector for HPLC peaks containing specific elements. Detection limits for a number of elements have been evaluated in terms of the minimum detectable concentration of the element at the chromatographic peak maximum. The elements studies were Al, As, B, Ba, Ca, Cd, Co, Cr, Cu, Fe, K, Li, Mg, Mn, Mo, Na, Ni, P, Pb, Sb, Se, Sr, Ti, V, and Zn. In addition, ICP was compared with atomic absorption spectrometry for the detection of HPLC peaks composed of EDTA and NTA chelates of copper. Furthermore, ICP was compared to uv solution absorption for the detection of copper chelates. 6 figures, 4 tables

  11. Liquid-chromatographic analysis for cyclosporine with use of a microbore column and small sample volume.

    Science.gov (United States)

    Annesley, T; Matz, K; Balogh, L; Clayton, L; Giacherio, D

    1986-07-01

    This liquid-chromatographic assay requires 0.2 to 0.5 mL of whole blood, avoids the use of diethyl ether, and consumes only 10 to 20% of the solvents used in prior methods. Sample preparation involves an acidic extraction with methyl-t-butyl ether, performed in a 13 X 100 mm disposable glass tube, then a short second extraction of the organic phase with sodium hydroxide. After evaporation of the methyl-t-butyl ether, chromatography is performed on an "Astec" 2.0-mm (i.d.) octyl column. We compared results by this procedure with those by use of earlier larger-scale extractions and their respective 4.6-mm (i.d.) columns; analytical recoveries of cyclosporins A and D were comparable with previous findings and results for patients' specimens were equivalent, but the microbore columns provided greatly increased resolution and sensitivity.

  12. High-performance liquid chromatographic analysis of anthraquinone compounds in the Laurera benguelensis

    Science.gov (United States)

    Manojlović, N.; Marković, Z.; Gritsanapan, W.; Boonpragob, K.

    2009-09-01

    A high-performance liquid chromatographic (HPLC) method has been developed for the characterization of anthraquinone metabolites in extracts of the lichen Laurera benguelensis. With this method four anthraquinone derivatives 1,8-dihydroxy-3-methoxy-6-methylanthraquinone, 1,8-dihydroxy-3-formyl-6-methoxyanthraquinone, 1,8-dihydroxy-3-hydroxymethyl-6-methoxy-anthraquinone and 1,3,8-trihyroxy-6-methylanthraquinone can be analyzed. Components of lichen were detected by characteristic ultraviolet spectra and relative retention times. This is first report of phytochemical analysis of L. benguelensis. Importance of this research is in recognizing some new source (lichen and its extracts) as a natural emplacement of antioxidants because oxidation with free radicals or autooxidation is big problem for preservation of food products.

  13. High-performance liquid chromatographic analysis of methadone hydrochloride oral solution.

    Science.gov (United States)

    Beasley, T H; Ziegler, H W

    1977-12-01

    A direct and rapid high-performance liquid chromatographic assay for methadone hydrochloride in a flavored oral solution dosage form is described. A syrup sample, one part diluted with three parts of water, is introduced onto a column packed with octadecylsilane bonded on 10 micrometer porous silica gel (reversed phase). A formic acid-ammonium formate-buffered mobile phase is linear programmed with acetonitrile. The absorbance is monitored continuously at 280 or 254 nm, using a flow-through, UV, double-beam photometer. An aqueous methadone hydrochloride solution is used for external standardization. The relative standard deviation was not more than 1.0%. Drug recovery from a syrup base was better than 99.8%.

  14. [Reversed-phase high-performance liquid chromatograph--application to serum aluminium monitoring].

    Science.gov (United States)

    Hoshino, H; Kaneko, E

    1996-01-01

    High-Performance Liquid Chromatography (HPLC) with the reversed-phase partition mode separation (including ion-pair one) towards metal chelate compounds prepared in an off-line fashion (precolumn chelation) is most versatile in terms of high sensitivity with base-line flatness, unique selectivity and cost effectiveness. The extraordinary toughness to the complicated matrices encountered in clinical testing is exemplified by the successful application to the aluminium monitoring of human serum samples. The A1 chelate with 2,2'-dihydroxyazobenzene is efficiently chromatographed on a LiChroCART RP-18 column using an aqueous methanol eluent (63.6 wt%) containing tetrabutylammonium bromide as an ion-pair agent. The serum concentration level of A1 down to 6 micrograms dm-3 is readily monitored without influences from iron, chyle and haemolysis.

  15. Liquid-chromatographic determination of sarafloxacin residues in channel catfish muscle-tissue

    Science.gov (United States)

    Meinertz, J.R.; Dawson, V.K.; Gingerich, W.H.; Cheng, B.; Tubergen, M.M.

    1994-01-01

    A liquid chromatographic method is described for the determination of sarafloxacin hydrochloride residues i n channel catfish (ictalurus punctatus) fillets. Sarafloxacin was extracted from fillet tissue with acetonitrile=water (1 + 1). The extract was centrifuged and the supernatant was partitioned with hexane. The aqueous fraction was filtered through a 0.45 Mum filter and evaporated to dryness. The sample was redissolved with 20% acetonitrile-methanol (3 + 2) and 80% trifluoroacetic acid (0.1%), Centrifuged, and filtered to remove proteins. Samples were analyzed by chromatography with gradient elution on a c18 column and with fluorescence detection (excitation at 280 nm and emission above 389 nm). Mean recoveries ranged from 85.4 To 104%, and relative standard deviations ranged from 1.06 To 5.58% In samples spiked at concentrations of 10.0-863.8 Ng/g. The method detection limit for sarafloxacin was 1.4 Ng/g.

  16. High-performance liquid chromatographic quantitation of desmosine plus isodesmosine in elastin and whole tissue hydrolysates

    International Nuclear Information System (INIS)

    Soskel, N.T.

    1987-01-01

    Quantitation of desmosine and isodesmosine, the major crosslinks in elastin, has been of interest because of their uniqueness and use as markers of that protein. Accurate measurement of these crosslinks may allow determination of elastin degradation in vivo and elastin content in tissues, obviating lengthy extraction procedures. We have developed a method of quantitating desmosine plus isodesmosine in hydrolysates of tissue and insoluble elastin using high-performance liquid chromatographic separation and absorbance detection that is rapid (21-35 min) and sensitive (accurate linearity from 100 pmol to 5 nmol). This method has been used to quantitate desmosines in elastin from bovine nuchal ligament and lung and in whole aorta from hamsters. The ability to completely separate [ 3 H]lysine from desmosine plus isodesmosine allows the method to be used to study incorporation of lysine into crosslinks in elastin

  17. Simultaneous determination of midazolam and 1'-hydroxymidazolam in human plasma by liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Li, Wenkui; Luo, Suyi; Smith, Harold T; Tse, Francis L S

    2007-08-01

    A sensitive and simple liquid chromatography-tandem mass spectrometry method for the determination of midazolam and 1'-hydroxymidazolam in human plasma has been developed and validated with a dynamic range of 0.1-250 ng/mL. The analysis was based on semi-automated liquid-liquid extraction followed by evaporation of the extraction solvent, reconstitution and chromatography on a reversed-phase C(18) column. The mobile phase consists of 5 mm ammonium acetate and methanol and runs in gradient at a flow rate of 0.25 mL/min with column temperature of approximately 20 degrees C. The entire column effluent was transferred into the LC-MS/MS interface operated in positive electrospray ionization mode. The chromatographic run time was 4.3 min per injection, with retention times for midazolam, 1'-hydroxymidazolaml and the internal standard, triazolam, of 2.5, 2.3 and 2.1 min, respectively. The intra-day and inter-day precision (RSD %) and accuracy (bias %) of the quality control samples were <15.0% and within +/-13%, respectively. The current method has been applied to a clinical drug-drug interaction study in human. Copyright (c) 2007 John Wiley & Sons, Ltd.

  18. Instrumental liquid chromatography: a practical manual on high-performance liquid chromatographic methods

    National Research Council Canada - National Science Library

    Parris, N. A

    1976-01-01

    Available texts on liquid chromatography have tended to emphasize the developments in the theoretical understanding of the technique and methodology or to list numerous applications, complete with experimental details...

  19. Abnormal tyrosine and phenylalanine metabolism in patients with tyrosyluria and phenylketonuria; gas-liquid chromatographic analysis of urinary metabolites

    NARCIS (Netherlands)

    Wadman, S.K.; Heiden, C. van der; Ketting, D.; Sprang, F.J. van

    Gas-liquid chromatographic methods have been developed for the analysis of: urinary phenylalanine metabolites (I) in patients with phenylketonuria, tyrosine metabolites (II) in patients with a disturbed tyrosine metabolism at the level of p-hydroxyphenylpyruvate hydroxylase, and homogentisic acid in

  20. Analysis of small carbohydrates in several bioactive botanicals by gas chromatography with mass spectrometry and liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Moldoveanu, Serban; Scott, Wayne; Zhu, Jeff

    2015-11-01

    Bioactive botanicals contain natural compounds with specific biological activity, such as antibacterial, antioxidant, immune stimulating, and taste improving. A full characterization of the chemical composition of these botanicals is frequently necessary. A study of small carbohydrates from the plant materials of 18 bioactive botanicals is further described. The study presents the identification of the carbohydrate using a gas chromatographic-mass spectrometric analysis that allows detection of molecules as large as maltotetraose, after changing them into trimethylsilyl derivatives. A number of carbohydrates in the plant (fructose, glucose, mannose, sucrose, maltose, xylose, sorbitol, and myo-, chiro-, and scyllo-inositols) were quantitated using a novel liquid chromatography with tandem mass spectrometric technique. Both techniques involved new method developments. The gas chromatography with mass spectrometric analysis involved derivatization and separation on a Rxi(®)-5Sil MS column with H2 as a carrier gas. The liquid chromatographic separation was obtained using a hydrophilic interaction type column, YMC-PAC Polyamine II. The tandem mass spectrometer used an electrospray ionization source in multiple reaction monitoring positive ion mode with the detection of the adducts of the carbohydrates with Cs(+) ions. The validated quantitative procedure showed excellent precision and accuracy allowing the analysis in a wide range of concentrations of the analytes. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Characterization of crude oils and petroleum products: (I Elution liquid chromatographic separation and gas chromatographic analysis of crude oils and petroleum products

    Directory of Open Access Journals (Sweden)

    E.O. Odebunmi

    2002-12-01

    Full Text Available Some physical and chemical properties of samples of light, medium and heavy Nigerian crude oils and petroleum products including gasoline, kerosene and engine oil have been measured and are reported in this paper. The crude oils and petroleum products have also been characterized by fractional distillation and elution liquid chromatography. The fractions obtained from elution liquid chromatography were analyzed using gas chromatography (GC. The GC fractions were identified by comparing the retention time of peaks in the unknown samples with those of components of calibration standard mixtures. The importance of the physico-chemical properties and the significance of the fractional distillation and chromatographic separation methods to industrial process operations have been discussed.

  2. Characterization of lipopeptides produced by Bacillus licheniformis using liquid chromatography with accurate tandem mass spectrometry.

    Science.gov (United States)

    Favaro, Gabriella; Bogialli, Sara; Di Gangi, Iole Maria; Nigris, Sebastiano; Baldan, Enrico; Squartini, Andrea; Pastore, Paolo; Baldan, Barbara

    2016-10-30

    The plant endophyte Bacillus licheniformis, isolated from leaves of Vitis vinifera, was studied to individuate and characterize the presence of bioactive lipopeptides having amino acidic structures. Crude extracts of liquid cultures were analyzed by ultra-high-performance liquid chromatography (UHPLC) coupled to a quadrupole time-of-flight (QTOF) mass analyzer. Chromatographic conditions were optimized in order to obtain an efficient separation of the different isobaric lipopeptides, avoiding merged fragmentations of co-eluted isomeric compounds and reducing possible cross-talk phenomena. Composition of the amino acids was outlined through the interpretation of the fragmentation behavior in tandem high-resolution mass spectrometry (HRMS/MS) mode, which showed both common-class and peculiar fragment ions. Both [M + H](+) and [M + Na](+) precursor ions were fragmented in order to differentiate some isobaric amino acids, i.e. Leu/Ile. Neutral losses characteristic of the iso acyl chain were also evidenced. More than 90 compounds belonging to the classes of surfactins and lichenysins, known as biosurfactant molecules, were detected. Sequential LC/HRMS/MS analysis was used to identify linear and cyclic lipopeptides, and to single out the presence of a large number of isomers not previously reported. Some critical issues related to the simultaneous selection of different compounds by the quadrupole filter were highlighted and partially solved, leading to tentative assignments of several structures. Linear lichenysins are described here for the first time. The approach was proved to be useful for the characterization of non-target lipopeptides, and proposes a rationale MS experimental scheme aimed to investigate the difference in amino acid sequence and/or in the acyl chain of the various congeners, when standards are not available. Results expanded the knowledge about production of linear and cyclic bioactive compounds from Bacillus licheniformis, clarifying the

  3. Detection of 10 sweeteners in various foods by liquid chromatography/tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Chui-Shiang Chang

    2014-09-01

    Full Text Available The analytical method for sweeteners in various food matrixes is very important for food quality control and regulation enforcement. A simple and rapid method for the simultaneous determination of 10 sweeteners [acesulfame potassium (ACS-K, aspartame (ASP, cyclamate (CYC, dulcin (DUL, glycyrrhizic acid (GA, neotame (NEO, neohesperidin dihydrochalcone (NHDC, saccharin (SAC, sucralose (SCL, and stevioside (STV] in various foods by liquid chromatography/tandem mass chromatography (LC–MS/MS was developed. The chromatographic separation was performed on a Phenomenex Luna Phenyl-Hexyl (5 μm, 4.6 mm × 150 mm column with gradient elution of 10 mM ammonium acetate in water and 10 mM ammonium acetate in methanol. The recoveries of the 10 sweeteners were between 75% and 120%, and the coefficients of variation were less than 20%. The limits of quantification were 0.5 μg/kg for NHDC and SCL. For the other sweeteners, the limits of quantification were 0.1 μg/kg. Compared to the traditional high-performance liquid chromatography method, the LC–MS/MS method could provide better sensitivity, higher throughput, enhanced specificity, and more sweeteners analyzed in a single run. The samples included 27 beverages (16 alcoholic and 11 nonalcoholic beverages and 15 pickled foods (1 pickled pepper, 3 candies, and 11 candied fruits. Two remanufactured wines were found to contain 7.2, 8.5 μg/g SAC and 126.5, 123 μg/g CYC, respectively. ACS-K, ASP, SCL, and NEO were detected in five beverages and drinks. The pickled peppers and candied fruits were found to contain SAC, GA, CYC, ASP, STV, NEO, and ACS-K. The wine with sweeteners detected was remanufactured wine, not naturally fermented wine. Therefore, the ingredient label for the sweeteners of remanufactured wine should be regulated by the proper authority for inspection of sweeteners.

  4. Quantitative selenium speciation in human urine by using liquid chromatography–electrospray tandem mass spectrometry

    International Nuclear Information System (INIS)

    Lu Ying; Rumpler, Alice; Francesconi, Kevin A.; Pergantis, Spiros A.

    2012-01-01

    Highlights: ► Development of a selected reaction monitoring mass spectrometric method for the identification of Se species in human urine. ► A selenosugar was detected as the major human urinary metabolite of selenium in the samples analysed. ► The trimethylselenonium ion was detected in the urine of one volunteer before and after receiving a selenium supplement. ► Strict quality control measures were applied to validate identification. ► Quantitation was conducted using an isotopically labelled internal standard and the standard additions methodology. - Abstract: A liquid chromatography–electrospray-tandem mass spectrometry (ES-MS/MS) method was developed for the speciation analysis of four organic selenium species of relevance to human urinary metabolism, namely trimethylselenomium ion (TMSe + ), selenomethionine (SeMet) and the two selenosugars, methyl 2-acetamido-2-deoxy-1-seleno-β-D-galactos/-glucos-amine (SeGalNAc and SeGluNAc, respectively). Their chromatographic separation was achieved by using a cation exchange pre-column coupled in-series with a reversed-phase high-performance liquid chromatography column, along with an isocratic mobile phase. Online detection was performed using ES-MS/MS in selective reaction monitoring mode. SeGalNAc was detected as the major human urinary metabolite of selenium in the samples analysed, whereas TMSe + was detected in the urine of one volunteer before and after receiving a selenium supplement. SeMet was not detected as a urine excretory metabolite in this study. Spiking experiments performed with the urine samples revealed significant signal suppression caused by coeluting matrix constituents. To overcome such interferences, isotopically labelled 13 CD 3 82 SeGalNAc was used as an internal standard, whereas in the absence of an isotopically labelled internal standard for TMSe + , the standard addition method was applied. Quality control for the accurate quantitation of TMSe + and SeGalNAc was carried out by

  5. Glucose and glycerol concentrations and their tracer enrichment measurements using liquid chromatography tandem mass spectrometry

    DEFF Research Database (Denmark)

    Bornø, Andreas; Foged, Lene; van Hall, Gerrit

    2014-01-01

    The present study describes a new liquid chromatography tandem mass spectrometry method for high-throughput quantification of glucose and glycerol in human plasma using stable isotopically labeled internal standards and is suitable for simultaneous measurements of glucose and glycerol enrichments...... of variation were 2.0% and 9.7%, respectively. After derivatization, plasma samples were stable for at least 14 days. In conclusion, we have developed and validated a novel, accurate, and sensitive high-throughput liquid chromatography tandem mass spectrometry method for simultaneous determination of glucose...

  6. A Liquid Chromatography - Tandem Mass Spectrometry Approach for the Identification of Mebendazole Residue in Pork, Chicken, and Horse.

    Directory of Open Access Journals (Sweden)

    Ji Sun Lee

    Full Text Available A confirmatory and quantitative method of liquid chromatography-tandem mass spectrometry (LC-MS/MS for the determination of mebendazole and its hydrolyzed and reduced metabolites in pork, chicken, and horse muscles was developed and validated in this study. Anthelmintic compounds were extracted with ethyl acetate after sample mixture was made alkaline followed by liquid chromatographic separation using a reversed phase C18 column. Gradient elution was performed with a mobile phase consisting of water containing 10 mM ammonium formate and methanol. This confirmatory method was validated according to EU requirements. Evaluated validation parameters included specificity, accuracy, precision (repeatability and within-laboratory reproducibility, analytical limits (decision limit and detection limit, and applicability. Most parameters were proved to be conforming to the EU requirements. The decision limit (CCα and detection capability (CCβ for all analytes ranged from 15.84 to 17.96 μgkg-1. The limit of detection (LOD and the limit of quantification (LOQ for all analytes were 0.07 μgkg-1 and 0.2 μgkg-1, respectively. The developed method was successfully applied to monitoring samples collected from the markets in major cities and proven great potential to be used as a regulatory tool to determine mebendazole residues in animal based foods.

  7. A rapid gas chromatographic injection-port derivatization method for the tandem mass spectrometric determination of patulin and 5-hydroxymethylfurfural in fruit juices.

    Science.gov (United States)

    Marsol-Vall, Alexis; Balcells, Mercè; Eras, Jordi; Canela-Garayoa, Ramon

    2016-07-01

    A novel method consisting of injection-port derivatization coupled to gas chromatography-tandem mass spectrometry is described. The method allows the rapid assessment of 5-hydroxymethylfurfural (HMF) and patulin content in apple and pear derivatives. The chromatographic separation of the compounds was achieved in a short chromatographic run (12.2min) suitable for routine controls of these compounds in the fruit juice industry. The optimal conditions for the injection-port derivatization were at 270°C, 0.5min purge-off, and a 1:2 sample:derivatization reagent ratio (v/v). These conditions represent an important saving in terms of derivatization reagent consumption and sample preparation time. Quality parameters were assessed for the target compounds, giving LOD of 0.7 and 1.6μg/kg and LOQ of 2 and 5μg/kg for patulin and HMF, respectively. These values are below the maximum patulin concentration in food products intended for infants and young children. Repeatability (%RSD n=5) was below 12% for both compounds. In addition, the method linearity ranged between 25 and 1000μg/kg and between 5 and 192μg/kg for HMF and patulin, respectively. Finally, the method was applied to study HMF and patulin content in various fruit juice samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Liquid chromatography-tandem mass spectrometry determination of synthetic cathinones and phenethylamines in influent wastewater of eight European cities

    DEFF Research Database (Denmark)

    Bade, Richard; Bijlsma, Lubertus; Sancho, Juan V.

    2017-01-01

    (SPE) with Oasis MCX cartridges. Isotopically labelled internal standards were used to correct for matrix effects and potential SPE losses. Following chromatographic separation on a C18 column within 6 min, the compounds were measured by tandem mass spectrometry in positive ionization mode. The method...

  9. A rapid hydrophilic interaction liquid chromatographic determination of glimepiride in pharmaceutical formulations

    Directory of Open Access Journals (Sweden)

    Si Zhou

    2017-09-01

    Full Text Available Glimepiride is one of the most widely prescribed antidiabetic drugs and contains both hydrophobic and hydrophilic functional groups in its molecules, and thus could be analyzed by either reversed-phase high performance liquid chromatography (HPLC or hydrophilic interaction liquid chromatography (HILIC. In the literature, however, only reversed-phase HPLC has been reported. In this study, a simple, rapid and accurate hydrophilic interaction liquid chromatographic method was developed for the determination of glimepiride in pharmaceutical formulations. The analytical method comprised a fast ultrasound-assisted extraction with acetonitrile as a solvent followed by HILIC separation and quantification using a Waters Spherisorb S5NH2 hydrophilic column with a mobile phase consisting of acetonitrile and aqueous acetate buffer (5.0 mM. The retention time of glimepiride increased slightly with decrease of mobile phase pH value from 6.8 to 5.8 and of acetonitrile content from 60% to 40%, indicating that both hydrophilic, ionic, and hydrophobic interactions were involved in the HILIC retention and elution mechanisms. Quantitation was carried out with a mobile phase of 40% acetonitrile and 60% aqueous acetate buffer (5.0 mM at pH 6.3, by relating the peak area of glimepiride to that of the internal standard, with a detection limit of 15.0 μg/L. UV light absorption responses at 228 nm were linear over a wide concentration range from 50.0 μg/L to 6.00 mg/L. The recoveries of the standard added to pharmaceutical tablet samples were 99.4–103.0% for glimepiride, and the relative standard deviation for the analyte was less than 1.0%. This method has been successfully applied to determine the glimepiride contents in pharmaceutical formulations.

  10. Simple and rapid determination of norethindrone in human plasma by supported liquid extraction and ultra performance liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Gong, Zhilong; Chandler, Kiresha; Webster, Stephen; Kerley, Remy; Buist, Susan; McCort-Tipton, Melanie

    2012-03-15

    We report for the first time an ultra performance liquid chromatographic method with tandem mass spectrometric detection (UPLC/MS/MS) for the determination of norethindrone alone in human plasma over the concentration range of 50.0-25000 pg mL(-1) using a sample volume of 0.250 mL. Norethindrone and its internal standard (ISTD), norethindrone-(13)C(2), were extracted from human plasma by supported liquid extraction (SLE). After evaporation of the organic solvent, samples were reconstituted and analyzed on an UPLC/MS/MS system. The UPLC system used a Waters BEH C18 (100 mm × 2.1mm, 1.7 μm) column with mobile phase A of 0.05% formic acid in water:acetonitrile (65:35, v/v) and mobile phase B of 0.05% formic acid in methanol:acetonitrile (50:50, v/v). The flow rate was 0.500 mL min(-1). The method was fully validated. The inter-run accuracy and precision at the lower limit of quantitation (LLOQ), low, mid and high quality control (QC) concentration levels were 99.2-108.4% with a <8.1% CV (coefficient of variation), respectively. The validated method has been successfully applied to analysis of thousands of pharmacokinetic samples. Copyright © 2012 Elsevier B.V. All rights reserved.

  11. Validation and implementation of liquid chromatographic-mass spectrometric (LC-MS) methods for the quantification of tenofovir prodrugs.

    Science.gov (United States)

    Hummert, Pamela; Parsons, Teresa L; Ensign, Laura M; Hoang, Thuy; Marzinke, Mark A

    2018-04-15

    The nucleotide reverse transcriptase inhibitor tenofovir (TFV) is widely administered in a disoproxil prodrug form (tenofovir disoproxil fumarate, TDF) for HIV management and prevention. Recently, novel prodrugs tenofovir alafenamide fumarate (TAF) and hexadecyloxypropyl tenofovir (CMX157) have been pursued for HIV treatment while minimizing adverse effects associated with systemic TFV exposure. Dynamic and sensitive bioanalytical tools are required to characterize the pharmacokinetics of these prodrugs in systemic circulation. Two parallel methods have been developed, one to combinatorially quantify TAF and TFV, and a second method for CMX157 quantification, in plasma. K 2 EDTA plasma was spiked with TAF and TFV, or CMX157. Following the addition of isotopically labeled internal standards and sample extraction via solid phase extraction (TAF and TFV) or protein precipitation (CMX157), samples were subjected to liquid chromatographic-tandem mass spectrometric (LC-MS/MS) analysis. For TAF and TFV, separation occurred using a Zorbax Eclipse Plus C18 Narrow Bore RR, 2.1 × 50 mm, 3.5 μm column and analytes were detected on an API5000 mass analyzer; CMX157 was separated using a Kinetex C8, 2.1 × 50 mm, 2.6 μm column and quantified using an API4500 mass spectrometer. Methods were validated according to FDA Bioanalytical Method Validation guidelines. Analytical methods: were optimized for the multiplexed monitoring of TAF and TFV, and CMX157 in plasma. The lower limits of quantification (LLOQs) for TAF, TFV, and CMX157 were 0.03, 1.0, and 0.25 ng/mL, respectively. Calibration curves were generated via weighted linear regression of standards. Intra- and inter-assay precision and accuracy studies demonstrated %CVs ≤ 14.4% and %DEVs ≤ ± 7.95%, respectively. Stability and matrix effects studies were also performed. All results were acceptable and in accordance with the recommended guidelines for bioanalytical methods. Assays were also

  12. Micellar Liquid Chromatographic Determination of Carbaryl and 1-Naphthol in Water, Soil, and Vegetables

    Directory of Open Access Journals (Sweden)

    Mei-Liang Chin-Chen

    2012-01-01

    Full Text Available A liquid chromatographic procedure has been developed for the determination of carbaryl, a phenyl-N-methylcarbamate, and its main metabolite 1-naphthol, using a C18 column (250’mm’ × ’4.6’mm with a micellar mobile phase and fluorescence detection at maximum excitation/emission wavelengths of 225/333’nm, respectively. In the optimization step, surfactants sodium dodecyl sulphate (SDS, Brij-35 and N-cetylpyridinium chloride monohydrate, and organic solvents propanol, butanol, and pentanol were considered. The selected mobile phase was 0.15’M SDS-6% (v/v-pentanol-0.01’M NaH2PO4 buffered at pH 3. Validation studies, according to the ICH Tripartite Guideline, included linearity (r>0.999, limit of detection (5 and 18’ng mL-1, for carbaryl and 1-naphthol, resp., and limit of quantification (15 and 50’ng mL-1, for carbaryl and 1-naphthol, resp., with intra- and interday precisions below 1%, and robustness parameters below 3%. The results show that the procedure was adequate for the routine analysis of these two compounds in water, soil, and vegetables samples.

  13. Ion-pair high performance liquid chromatographic retention behavior of salicylic acid and its derivatives

    Energy Technology Data Exchange (ETDEWEB)

    Lee, K.W.; Chung, Y.S. [Chungbuk National University, Cheongju (Korea); Oh, S.K. [Handok Pharmaceuticals Co. Ltd., Chungbuk (Korea)

    1999-06-01

    The ion-pair high performance liquid chromatographic elution behavior of salicylic acid and its derivatives was studied with measuring capacity factor, k', changing the concentration of ion-pairing reagent (tetrabutylammonium chloride, TBACl) in mobile phase. As a result, it was found that k' of the samples increase at pH 7.2 as the TBACl concentration increase. The derivatives of salicylic acid were separated each other at an optimum mobile phase condition which was found from the observation of the retention behavior. The optimum mobile phase condition was methanol solution(MeOH:H{sub 2}O 30:70) containing 20 mM TBACl for the determination of salicylic acid and methanol solution (MeOH:H{sub 2}O 20:80) containing 40 mM TBACl for p-aminosalicylic acid at pH 7.2. The method has been applied for the analysis of the contents of salicylic acid derivatives in an aspirin tablet and a tuberculosis curing agent. 8 refs., 4 figs., 2 tabs.

  14. Liquid chromatographic determination of urinary 2-thiothiazolidine-4-carboxylic acid, a biomarker of carbon disulphide exposure.

    Science.gov (United States)

    Lee, B L; Yang, X F; New, A L; Ong, C N

    1995-06-23

    An effective gradient high-performance liquid chromatographic method for baseline separation of urinary 2-thiothiazolidine-4-carboxylic acid (TTCA), with photodiode array detection at 271 nm was described. o-Methylhippuric acid was used as an internal standard (I.S.). A 1-ml urine sample was saturated with 300 mg of sodium sulphate, acidified with 100 microliters of 6 M hydrochloric acid, extracted twice with 2 ml of diethyl ether, and after evaporation, the residue was taken up in 1 ml of 0.1% (v/v) phosphoric acid. The two mobile phases used for gradient elution were: (A) 10 mM ammonium dihydrogenphosphate (pH 3.5) and (B) same concentration of buffer but containing 20% (v/v) of methanol (pH 4.8). The flow-rate was set at 1.0 ml/min. TTCA and I.S. were detected at 2.2 and 9.1 min, respectively. The method was validated with urine samples collected from normal subjects and workers occupationally exposed to carbon disulphide. The present method enables the detection of urinary TTCA at a concentration of 0.025 mg/l. Analytical recovery and reproducibility generally exceeded 90%. The proposed method is considered more sensitive, specific and reliable than other existing methods.

  15. Validation of a liquid chromatographic method for the pharmaceutical quality control of products containing elacridar

    Directory of Open Access Journals (Sweden)

    Emilia Sawicki

    2016-08-01

    Full Text Available Many anticancer drugs have an impaired bioavailability and poor brain penetration because they are substrates to drug efflux pumps such as P-glycoprotein and Breast Cancer Resistance Protein. Elacridar is a strong inhibitor of these two drug efflux pumps and therefore has great potential to improve oral absorption and brain penetration of many anticancer drugs. Currently, a clinical formulation of elacridar is unavailable and therefore the pharmaceutical development of a drug product is highly warranted. This also necessitates the availability of an analytical method for its quality control. A reverse-phase high-performance liquid chromatographic method with ultraviolet detection was developed for the pharmaceutical quality control of products containing elacridar as the active pharmaceutical ingredient. The analytical method was validated for linearity, accuracy, precision, selectivity, carry-over, stability of stock and reference solutions, stability of the final extract, stability-indicating capability and impurity testing. We found that elacridar is unstable in aqueous solutions that are exposed to light because a hydroxylation product of elacridar is formed. Therefore, sample solutions with elacridar must be protected from light.

  16. Liquid chromatographic determination of oxytetracycline in edible fish fillets from six species of fish

    Science.gov (United States)

    Meinertz, J.R.; Stehly, G.R.; Gingerich, W.H.

    1998-01-01

    The approved use of oxytetracycline (OTC) in U.S. Aquaculture is limited to specific diseases in salmonids and channel catfish. OTC may also be effective in controlling diseases in other fish species important to public aquaculture, but before approved use of OTC can be augmented, an analytical method for determining OTC in fillet tissue from multiple species of fish will be required to support residue depletion studies. The objective of this study was to develop and validate a liquid chromatographic (LC) method that is accurate, precise, and sensitive for OTC in edible fillets from multiple species of fish. Homogenized fillet tissues from walleye, Atlantic salmon, striped bass, white sturgeon, rainbow trout, and channel catfish were fortified with OTC at nominal concentrations of 10, 20, 100, 1000, and 5000 ng/g. In tissues fortified with OTC at 100, 1000, and 5000 ng/g, mean recoveries ranged from 83 to 90%, and relative standard deviations (RSDs) ranged from 0.9 to 5.8%. In all other tissues, mean recoveries ranged from 59 to 98%, and RSDs ranged from 3.3 to 20%. Method quantitation limits ranged from 6 to 22 ng/g for the 6 species. The LC parameters produced easily integratable OTC peaks without coelution of endogenous compounds. The method is accurate, precise, and sensitive for OTC in fillet tissue from 6 species of fish from 5 phylogenetically diverse groups.

  17. Liquid chromatographic method for determining the concentration of bisazir in water

    Science.gov (United States)

    Scholefield, Ronald J.; Slaght, Karen S.; Allen, John L.

    1997-01-01

    Barrier dams, traps, and lampricides are the techniques currently used by the Great Lakes Fishery Commission to control sea lampreys (Petromyzon marinus) in the Great Lakes. To augment these control techniques, a sterile-male-release research program was initiated at the Lake Huron Biological Station. Male sea lampreys were sterilized by intraperitoneal injection of the chemical sterilant P,P-bis(1-aziridinyl)-N-methylphosphinothioic amide (bisazir). An analytical method was needed to quantitate the concentration of bisazir in water and to routinely verify that bisazir (>25 μg/L) does not persist in the treated effluent discharged from the sterilization facility to Lake Huron. A rapid, accurate, and sensitive liquid chromatographic (LC) method was developed for determining bisazir in water. Bisazir was dissolved in Lake Huron water; extracted and concentrated on a C18 solid-phase extraction column; eluted with methanol; and quantitated by reversed-phase LC using a C18 column, a mobile phase of 70% water and 30% methanol (v/v), and UV detection (205 nm). Bisazir retention time was 7-8 min; total run time was about 20 min. Method detection limit for bisazir dissolved in Lake Huron water was about 15 μg/L. Recovery from Lake Huron water fortified with bisazir at 100 μg/L was 94% (95% confidence interval, 90.2-98.2%).

  18. Peak distortion in the column liquid chromatographic determination of omeprazole dissolved in borax buffer.

    Science.gov (United States)

    Arvidsson, T; Collijn, E; Tivert, A M; Rosén, L

    1991-11-22

    Injection of a sample containing omeprazole dissolved in borax buffer (pH 9.2) into a reversed-phase liquid chromatographic system consisting of a mixture of acetonitrile and phosphate buffer (pH 7.6) as the mobile phase and a C18 surface-modified silica as the solid phase resulted under special conditions in split peaks of omeprazole. The degree of peak split and the retention time of omeprazole varied with the concentration of borax in the sample solution and the ionic strength of the mobile phase buffer as well as with the column used. Borax is eluted from the column in a broad zone starting from the void volume of the column. The retention is probably due to the presence of polyborate ions. The size of the zone varies with the concentration of borax in the sample injected. In the borax zone the pH is increased compared with the pH of the mobile phase, and when omeprazole (a weak acid) is co-eluting in the borax zone its retention is affected. In the front part and in the back part of the borax zone, pH gradients are formed, and these gradients can induce the peak splitting. When the dissolving medium is changed to a phosphate buffer or an ammonium buffer at pH 9 no peak distortion of omeprazole is observed.

  19. Liquid chromatographic and ultraviolet spectrophotometric determination of bevantolol and hydrochlorothiazide in feeds.

    Science.gov (United States)

    Spurlock, C H; Schneider, H G

    1984-01-01

    Separate assay methods have been developed for the 2 components of an 80 + 20 drug blend of bevantolol and hydrochlorothiazide (HCT) in admixtures with animal feed. Drug/diet admixtures are extracted with methanol for reverse phase ion-pair liquid chromatographic (LC) assay of bevantolol, and with acetonitrile for ultraviolet spectrophotometric assay of HCT. Bevantolol, a cardioselective beta blocker, is separated from soluble feed components with an RP-18 column, using methanol-water-acetic acid (60 + 40 + 1) containing 0. 005M octane-sulfonic acid, sodium salt, as ion-pairing reagent. HCT is determined spectrophotometrically in acetonitrile extracts, using a suitable blank extract as reference. Average recovery of HCT from an admixture of 0.5 mg blend/g diet is 94.5% +/- 4.3 RSD and at 2.0 mg/g, 101.5% +/- 3.5 RSD. Bevantolol recovery from the same admixtures is 101.8% +/- 2.7 RSD and 99.0% +/- 3.5 RSD, respectively, using the method as described.

  20. Liquid chromatographic determination of pioglitazone in pharmaceuticals, serum and urine samples

    International Nuclear Information System (INIS)

    Abro, K.; Memon, N.; Bhanger, M.I.; Mahesar, S.A.; Parveen, S.

    2011-01-01

    A rapid and reliable analytical method based on high-performance liquid chromatography (HPLC) with UV detection (221 nm) has been developed for the determination of the anti-hyper glycemic agent Pioglitazone in pharmaceutical formulations and biological fluids (serum and urine) after clean-up with solid-phase extraction. Chromatographic separation was achieved with a Chromolith Performance RP-18e (10 4.6mm) column using mobile phase composition of acetonitrile: mixed phosphate buffer (pH 2.5; 10mM) (30:70, v/v) with a flow rate of 2.0mL/min. The total run time was 2 min. under optimized conditions. The calibration curve was found to be linear in the range of 1-10 mu g mL/sup -1/ with regression coefficient of 0.9996, and the lower limit of detection 72 ng/20 mu L injection. The method has been validated for the system suitability, linearity, precision and accuracy, limits of detection, specificity, stability and robustness. The %recovery of Pioglitazone in pharmaceutical formulations was found to be 104.7%. The assay has been applied successfully to the pharmaceutical Tablet samples and biological fluids (serum and urine) of healthy volunteers. (author)

  1. Preparation of milk samples for immunoassay and liquid chromatographic screening using matrix solid-phase dispersion.

    Science.gov (United States)

    Barker, S A; Long, A R

    1994-01-01

    The use of drugs to maintain the health and maximize the output of dairy cattle has made the monitoring of milk for such agents essential. Screening tests based on immunological, microbial inhibition, and bacterial receptor assays have been developed for the detection of violative levels of therapeutic substances. However, such assays are not infallible, and false positive or negative results can occur when contaminants bind receptors or compete for the binding of the target residues. Such effects may arise from dietary sources, diseases, or other variables. Thus, a violation by such a test is not definitive until further confirmation is obtained. Our laboratory has developed extraction procedures for several drugs used in dairy production. Our method uses matrix solid-phase dispersion (MSPD) to isolate drugs away from contaminants and to eliminate many possible interferences. MSPD can also be used to enhance the specificity of such assays by fractionating various classes of drugs that may cross-react. Similarly, such methods may be used for liquid chromatographic screening and confirmation of a suspect sample.

  2. Cytokinin profiling in plant tissues using ultra-performance liquid chromatography–electrospray tandem mass spectrometry

    Czech Academy of Sciences Publication Activity Database

    Novák, Ondřej; Hauserová, Eva; Amakorová, Petra; Doležal, Karel; Strnad, Miroslav

    2008-01-01

    Roč. 69, č. 11 (2008), s. 2214-2224 ISSN 0031-9422 R&D Projects: GA AV ČR KAN200380801 Institutional research plan: CEZ:AV0Z50380511 Keywords : Ultra-performance liquid chromatography (UPLC) * Tandem mass spectrometry (MS/MS) * Microextraction Subject RIV: EC - Immunology Impact factor: 2.946, year: 2008

  3. Development and Validation of Liquid Chromatographic Method for Estimation of Naringin in Nanoformulation

    Directory of Open Access Journals (Sweden)

    Kranti P. Musmade

    2014-01-01

    Full Text Available A simple, precise, accurate, rapid, and sensitive reverse phase high performance liquid chromatography (RP-HPLC method with UV detection has been developed and validated for quantification of naringin (NAR in novel pharmaceutical formulation. NAR is a polyphenolic flavonoid present in most of the citrus plants having variety of pharmacological activities. Method optimization was carried out by considering the various parameters such as effect of pH and column. The analyte was separated by employing a C18 (250.0 × 4.6 mm, 5 μm column at ambient temperature in isocratic conditions using phosphate buffer pH 3.5: acetonitrile (75 : 25% v/v as mobile phase pumped at a flow rate of 1.0 mL/min. UV detection was carried out at 282 nm. The developed method was validated according to ICH guidelines Q2(R1. The method was found to be precise and accurate on statistical evaluation with a linearity range of 0.1 to 20.0 μg/mL for NAR. The intra- and interday precision studies showed good reproducibility with coefficients of variation (CV less than 1.0%. The mean recovery of NAR was found to be 99.33 ± 0.16%. The proposed method was found to be highly accurate, sensitive, and robust. The proposed liquid chromatographic method was successfully employed for the routine analysis of said compound in developed novel nanopharmaceuticals. The presence of excipients did not show any interference on the determination of NAR, indicating method specificity.

  4. Comparative in vitro assessment of tolterodine tartrate tablets by high performance liquid chromatographic (HPLC

    Directory of Open Access Journals (Sweden)

    Hossein Danafar

    2016-06-01

    Full Text Available Tolterodine tartrate, is a new, potent and competitive muscarinic receptor antagonist in clinical development for the treatment of urge incontinence and other symptoms of unstable bladder. The purpose of this study is to establish a reliable and quick method for the assignment of tolterodine tartrate by high performance liquid chromatography with ultraviolet detection (HPLC-UV. A rapid  and  sensitive  high  performance  liquid  chromatographic  (HPLC  method  has  been developed  for  determination  of  tolterodine tartrate.  Mobile phase was composed of phosphate acetate 0.1 M (pH 2.5-acetonitrile (50:50 v/v with a flow rate of 1.2 ml/min. The eluted peaks were detected by a UV detector was set at wavelength of 285 nm. The method was validated in the range of tolterodine tartrate concentrations from 10 to 100 µg/ml. The limits of detection (LOD and quantitation (LOQ of the method were 5 and 10 µg/ml, respectively. The average drug recovery was 98.20 % throughout the linear concentration range. The average within-run and between-run accuracy values of 98.56 % and 99.11 % respectively. Statistical  assessment  of  various  in  vitro  dissolution  parameters  and  assay  results was  also  conducted  to  establish  if  there were  any significant difference among them. The validated HPLC method has been used successfully to study tolterodine tartrate.

  5. Improved Chromatographic Bioavailability Estimations

    National Research Council Canada - National Science Library

    Dorsey, John

    1996-01-01

    .... Since the inception of reversed phase liquid chromatography there have been many attempts to correlate chromatographic retention with bioavailability and the most often used bulk measure, the octanol...

  6. Performance characteristics of bioassay, radioenzymatic assay, homogeneous enzyme immunoassay, and high-performance liquid chromatographic determination of serum gentamicin

    International Nuclear Information System (INIS)

    Delaney, C.J.; Opheim, K.E.; Smith, A.L.; Plorde, J.J.

    1982-01-01

    We compared the accuracy, precision, and between-method error of the microbiological assay, the radioenzymatic assay, the homogeneous enzyme immunoassay, and the high-performance liquid chromatographic assay for the quantitation of gentamicin in serum. Precision and accuracy were evaluated by reference samples prepared to contain 0.0 to 32.7 micrograms of gentamicin per ml. Correlations between the methods utilized patient sera with gentamicin concentrations ranging from 0.6 to 13.3 micrograms/ml. All methods were reliable within acceptable limits for routine clinical use; intermethod correlation coefficients exceeded 0.96. Relative to the microbiological assay, the alternative methods offer the advantage of rapid analysis. The elapsed times for acquiring data on a set of 10 specimens under routine operating conditions were 0.5 h by the enzyme immunoassay, 4 h by the radioenzymatic assay, 5 h by the high-performance liquid chromatographic assay, and 10 h by the microbiological assay

  7. [Simultaneous determination of clevidipine butyrate and its metabolite clevidipine acid in dog blood by liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Wei, Hui-hui; Gu, Yuan; Liu, Yan-ping; Wei, Guang-li; Chen, Yong; Liu, Chang-xiao; Si, Duan-yun

    2015-10-01

    A rapid, sensitive and simple liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the simultaneous determination of clevidipine butyrate and its primary metabolite clevidipine acid in dog blood. After one-step protein precipitation with methanol, the chromatographic separation was carried out on an Ecosil C18 column (150 mm x 4.6 mm, 5 µm) with a gradient mobile phase consisting of methanol and 5 mmol · L(-1) ammonium formate. A chromatographic total run time of 13.0 min was achieved. The quantitation analysis was performed using multiple reaction monitoring (MRM) at the specific ion transitions of m/z 454.1 [M-H]- --> m/z 234.1 for clevidipine butyrate, m/z 354.0 [M-H]- --> m/z 208.0 for clevidipine acid and m/z 256.1 [M-H]- --> m/z 227.1 for elofesalamide (internal standard, IS) in the negative ion mode with electrospray ionization (ESI) source. The linear calibration curves for clevidipine butyrate and clevidipine acid were obtained in the concentration ranges of 0.5-100 ng · mL and 1-200 ng · mL(-1), separately. The lower limit of quantification of clevidipine butyrate and clevidipine acid were 0.5 ng · mL(-1) and 1 ng · mL(-1). The intra and inter-assay precisions were all below 12.9%, the accuracies were all in standard ranges. Stability testing indicated that clevidipine butyrate and clevidipine acid in dog blood with the addition of denaturant methanol was stable under various processing and/or handling conditions. The validated method has been successfully applied to a pharmacokinetic study of clevidipine butyrate injection to 8 healthy Beagle dogs following intravenous infusion at a flow rate of 5 mg · h(-1) for 0.5 h.

  8. Simultaneous determination of ribavirin and ribavirin base in monkey plasma by high performance liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Li, Wenkui; Luo, Suyi; Li, Shaoyong; Athill, Lawrence; Wu, Amy; Ray, Tapan; Zhou, Wei; Ke, June; Smith, Harold T; Tse, Francis L S

    2007-02-01

    For the first time, a liquid chromatographic method with tandem mass spectrometric detection (LC-MS/MS) for the simultaneous determination of ribavirin and rabavirin base was developed and validated over the concentration range of 10-5,000 ng/ml, respectively, using a 0.025 ml monkey plasma sample. Ribavirin, ribavirin base, and the internal standards were extracted from monkey plasma via protein precipitation. After evaporation of the supernatant, the extract was reconstituted with 5% methanol (containing 0.1% formic acid) and injected onto the LC-MS/MS system. Optimum chromatographic separation was achieved on a Waters Atlantis dc18 (150 mm x 2.1mm, 5 microm) column with mobile phase run in gradient with 100% water containing 0.5% formic acid (A) and 90% acetonitrile (containing 0.5% formic acid (B). The flow rate was 0.4-0.6 ml/min with total cycle time of approximately 7.0 min. Post-column addition of acetonitrile (containing 0.1% formic acid) at 0.3 ml/min was used to increase the ionization efficiency in the MS source. The method was validated for sensitivity, linearity, reproducibility, stability and recovery. Lack of adverse matrix effect and carry-over was also demonstrated. The intra-day and inter-day precision and accuracy of the quality control (QC) samples were <9.0% relative standard deviation (R.S.D.) and 10.8% bias for ribavirin, and 10.3% R.S.D. and 11.3% bias for ribavirin base. The current specific, accurate and precise assay is useful in support of the toxicokinetic and pharmacokinetic studies of these compounds.

  9. Development of a Multi-class Steroid Hormone Screening Method using Liquid Chromatography/Tandem Mass Spectrometry (LC-MS/MS)

    Science.gov (United States)

    Boggs, Ashley S. P.; Bowden, John A.; Galligan, Thomas M.; Guillette, Louis J.; Kucklick, John R.

    2016-01-01

    Monitoring complex endocrine pathways is often limited by indirect measurement or measurement of a single hormone class per analysis. There is a burgeoning need to develop specific direct-detection methods capable of providing simultaneous measurement of biologically relevant concentrations of multiple classes of hormones (estrogens, androgens, progestogens, and corticosteroids). The objectives of this study were to develop a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for multi-class steroid hormone detection using biologically relevant concentrations, then test limits of detection (LOD) in a high-background matrix by spiking charcoal-stripped fetal bovine serum (FBS) extract. Accuracy was tested with National Institute of Standards and Technology Standard Reference Materials (SRMs) with certified concentrations of cortisol, testosterone, and progesterone. 11-Deoxycorticosterone, 11-deoxycortisol, 17-hydroxypregnenolone, 17-hydroxyprogesterone, adrenosterone, androstenedione, cortisol, corticosterone, dehydroepiandrosterone, dihydrotestosterone, estradiol, estriol, estrone, equilin, pregnenolone, progesterone, and testosterone were also measured using isotopic dilution. Dansyl chloride (DC) derivatization was investigated maintaining the same method to improve and expedite estrogen analysis. Biologically relevant LODs were determined for 15 hormones. DC derivatization improved estrogen response two- to eight-fold, and improved chromatographic separation. All measurements had an accuracy ≤ 14 % difference from certified values (not accounting for uncertainty) and relative standard deviation ≤ 14 %. This method chromatographically separated and quantified biologically relevant concentrations of four hormone classes using highly specific fragmentation patterns and measured certified values of hormones that were previously split into three separate chromatographic methods. PMID:27039201

  10. Liquid chromatographic determination of polyphenenols in czech beers during brewing proces

    Directory of Open Access Journals (Sweden)

    Chunsriimyatav Ganbaatar

    2015-05-01

    Full Text Available High performance liquid chromatographic (HPLC/UV method was adapted for simultaneous determination of seven polyphenols, including derivatives of benzoic (gallic and vanillic acids and cinnamic acids (p-coumaric, ferulic and sinapic acids, flavan-3-ols (catechin and flavonols (rutin in worts and beers at the various stages of the brewing process. Based on the semi-quantitative HPLC analysis, total polyphenols chromatographic index (TPCI was in the ranges of 5.18 - 19.4 mg/L and 7.37 - 20.7 mg/L for all worts and beers, respectively. The HPLC analyses showed that relatively high levels of (+-catechin and gallic acid were in all the worts and the beers, while the values were much lower for ferulic acid, rutin, vanillic acid, sinapic acid and p-coumaric acid. Polyphenols with relatively high concentrations, that were detected in all tested worts and beers, were gallic acid (1.29 - 4.75 mg/L resp. 2.59 - 4.97 mg/L, (+-catechin (1.66 - 7.95 mg/L resp. 4.70 - 10.0 mg/L and ferulic acid (0.41 - 4.53 mg/L resp. 1.05 - 2.87 mg/L. On the other side, the sinapic acid (0.72 - 1.59 mg/L resp. 0.72 - 2.5 mg/L, rutin (1.17 - 2.03 mg/L resp. 1.16 - 2.85 mg/L, p-coumaric acid (ND - 4.73 mg/L resp. ND - 1.44 mg/L and vanillic acid (ND - 1.52 mg/L resp. 0.75 - 1.81 mg/L were detected in lowest concentrations. In both, worts and beers investigated in this study, the changes in the contents of individual polyphenols were not uniform. In the case of some polyphenols, a decrease in the content was observed after boiling the worts with hops or after the main fermentation until maturation and filtration, but with some polyphenols, the concentrations were constant until the end of the process or even increased.

  11. Reverse-Phase High-Performance Liquid Chromatographic Separation of Methylated and Non-Methylated Nucleic Acid Bases

    OpenAIRE

    Madyastha, Prema; Rao, Pratima; Deobagkar, DN; Madyastha, KM

    1983-01-01

    A high-performance liquid chromatographic sepration method is described for the detection of 5-methylcytosine and 6-methyladenine in nucleic acid ext. The bases were sepd. on a Waters $C18 \\mu$ Bondapak column with a water: methanol acetic acid system. Effluents were monitored by UV absorption at 254 nm. The bases were estd. by peak heights which are proportional to the amts. of the individual bases. The method is rapid, sensitive, easy to perform and reproducible.

  12. Storing of Extracts in Polypropylene Microcentrifuge Tubes Yields Contaminant Peak During Ultra-flow Liquid Chromatographic Analysis

    OpenAIRE

    Kshirsagar, Parthraj R.; Hegde, Harsha; Pai, Sandeep R.

    2016-01-01

    Background and Aim: This study was designed to understand the effect of storage in polypropylene microcentrifuge tubes and glass vials during ultra-flow liquid chromatographic (UFLC) analysis. Materials and Methods: One ml of methanol was placed in polypropylene microcentrifuge tubes (PP material, Autoclavable) and glass vials (Borosilicate) separately for 1, 2, 4, 8, 10, 20, 40, and 80 days intervals stored at ?4?C. Results: Contaminant peak was detected in methanol stored in polypropylene m...

  13. Liquid chromatography tandem mass spectrometry method for the estimation of lamotrigine in human plasma: Application to a pharmacokinetic study

    Directory of Open Access Journals (Sweden)

    Santosh Ghatol

    2013-04-01

    Full Text Available A reliable, selective and sensitive liquid chromatography tandem mass spectrometry method was developed and validated for the quantification of lamotrigine in human plasma using lamotrigine-13C3, d3 as an internal standard. Analyte and internal standard were extracted from human plasma by solid-phase extraction and detected in positive ion mode by tandem mass spectrometry with electrospray ionization (ESI interface. Chromatographic separation was performed on a Chromolith® SpeedROD; RP-18e column (50−4.6 mm i.d. using acetonitrile: 5±0.1 mM ammonium formate solution (90:10, v/v as the mobile phase at a flow rate of 0.500 mL/min. The calibration curves were linear over the range of 5.02–1226.47 ng/mL with the lower limit of quantitation validated at 5.02 ng/mL. The analytes were found stable in human plasma through three freeze (−20 °C-thaw (ice-cold water bath cycles and under storage on bench-top in ice-cold water bath for at least 6.8 h, and also in the mobile phase at 10 °C for at least 57 h. The method has shown good reproducibility, as the intra- and inter-day precisions were within 3.0%, while the accuracies were within ±6.0% of nominal values. The validated LC–MS/MS method was applied for the evaluation of pharmacokinetic and bioequivalence parameters of lamotrigine after an oral administration of 50 mg lamotrigine tablet to thirty-two healthy adult male volunteers. Keywords: Lamotrigine, Liquid chromatography/tandem mass spectrometry, Solid phase extraction, Pharmacokinetic study

  14. Screening and quantitative determination of twelve acidic and neutral pharmaceuticals in whole blood by liquid-liquid extraction and liquid chromatography-tandem mass spectrometry

    DEFF Research Database (Denmark)

    Simonsen, Kirsten Wiese; Steentoft, Anni; Buck, Maike

    2010-01-01

    . The method was fully validated for salicylic acid, paracetamol, phenobarbital, carisoprodol, meprobamate, topiramate, etodolac, chlorzoxazone, furosemide, ibuprofen, warfarin, and salicylamide. The method also tentatively includes thiopental, theophylline, piroxicam, naproxen, diclophenac, and modafinil......We describe a multi-method for simultaneous identification and quantification of 12 acidic and neutral compounds in whole blood. The method involves a simple liquid-liquid extraction, and the identification and quantification are performed using liquid chromatography-tandem mass spectrometry...

  15. Study on pharmacokinetics of 3,4-divanillyltetrahydrofuran in rats by ultra-fast liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Shan, Chen-Xiao; Cui, Xiao-Bing; Yu, Sheng; Chai, Chuan; Wen, Hong-Mei; Wang, Xin-Zhi; Sun, Xue

    2016-01-01

    3,4-Divanillyltetrahydrofuran is the main active ingredient of nettle root which can increase steroid hormones in the bloodstream for many of bodybuilders. To better understand its pharmacological activities, we need to determine its pharmacokinetic profiles. In this study, a rapid and sensitive ultra-fast liquid chromatography-tandem mass spectrometry (UFLC-MS/MS) method has been developed for the determination of 3,4-divanillyltetrahydrofuran in the plasma of rats. Chromatographic separation was performed on a C18 column at 40°C, with a gradient elution consisting of methanol and water containing 0.3% (v/v) formic acid at a flow rate of 0.8mL/min. The detection was performed using an electrospray triple-quadrupole MS/MS via positive ion multiple reaction monitoring mode. The lower limits-of-quantification determined were 0.5ng/mL. The intra- and inter-day precision (RSD%) was found to be within 15% and the accuracy (RE%) ranged from -4.0% to 7.0%. This simple yet sensitive method was fully validated and could be successfully applied to the study on pharmacokinetics of 3, 4-divanillyltetrahydrofuran. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Determination of Platycodin D and Platycodin D3 in Rat Plasma Using Liquid Chromatography-Tandem Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Tae-Hyun Kim

    2014-01-01

    Full Text Available Platycodon grandiflorum has long been used as a traditional oriental medicine for respiratory disorder. Platycodin D (PD is known as the main component isolated from the root of PG. A simple and rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS method has been developed and validated for the quantitation of PD in rat plasma. Quantitation was performed on a triple quadrupole mass spectrometer employing electrospray ionization and multiple reaction monitoring in positive ion mode. The total chromatographic run time was 4.0 min, and the calibration curves of PD were linear over the concentration range of 50–10,000 ng/mL in rat plasma. The coefficient of variation and relative error at five QC levels were 1.0 to 8.8% and 0.7 to 8.7%, respectively. After a single oral administration of 500 mg/kg and a single intravenous administration of 25 mg/kg of 3% PD extract (a PG extract including 3% of PD, platycodin D and platycodin D3 were detected and pharmacokinetic parameters were estimated. The oral bioavailability of platycodin D and platycodin D3 was 0.29% and 1.35% in rats at 500 mg/kg of 3% PD extract of PG, respectively. The present method can be applied to pharmacokinetic analysis of platycodins and platycosides of the PG.

  17. Quantitative analysis of multiple fatty acid ethanolamides using ultra-performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Lin, Lin; Yang, Haifeng; Jones, Peter J H

    2012-12-01

    Fatty acid ethanolamides (FAE) represent a group of lipid signaling molecules associated with many physiological and pharmacological actions; however, low FAE tissue levels pose challenges in terms of analytical characterization. The objective was to develop a competent ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for analysis of multiple FAE in animal and human tissue samples. Analytes were extracted using lipid-phase and solid-phase extraction procedures. Chromatographic separation was achieved using a gradient elution in 8 min. FAE were quantified by MS/MS in positive electrospray ionization mode. Linearity was shown in lower and higher FAE concentration ranges, with a limit of quantification (LOQ) ≤0.2 ng/ml for FAE including alpha-linolenoylethanolamide (ALEA), arachidonoylethanolamide (AEA), docosahexaenoylethanolamide (DHEA), linoleoylethanolamide (LEA), oleoylethanolamide (OEA) and palmitoylethanolamide (PEA). Accuracy was shown to be between 92.4% and 108.8%, and precision was <10% for all FAE species. In sum, this sensitive and reproducible method can be used to simultaneously determine multiple FAE at low concentrations in order to facilitate further study of the role of FAE on physiological state. Copyright © 2012 Elsevier Ltd. All rights reserved.

  18. Determination and Pharmacokinetics of Di-(2-ethylhexyl Phthalate in Rats by Ultra Performance Liquid Chromatography with Tandem Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Tung-Hu Tsai

    2013-09-01

    Full Text Available Di-(2-ethylhexyl phthalate (DEHP is used to increase the flexibility of plastics for industrial products. However, the illegal use of the plasticizer DEHP in food and drinks has been reported in Taiwan in 2011. In order to assess the exact extent of the absorption of DEHP via the oral route, the aim of this study is to develop a reliable and validated ultra performance liquid chromatography with tandem mass spectrometry (UPLC-MS/MS method to evaluate the oral bioavailability of DEHP in rats. The optimal chromatographic separation of DEHP and butyl benzyl phthalate (BBP; used as internal standard were achieved on a C18 column. The mobile phase was consisted of 5 mM ammonium acetate-methanol (11:89, v/v with a flow rate of 0.25 mL/min. The monitoring ion transitions were m/z 391.4 → 149.0 for DEHP and m/z 313.3 → 149.0 for BBP. The mean matrix effects of DEHP at low, medium and high concentrations were 94.5 ± 5.7% and 100.1 ± 2.3% in plasma and feces homogenate samples, respectively. In conclusion, the validated UPLC-MS/MS method is suitable for analyzing the rat plasma sample of DEHP and the oral bioavailability of DEHP was about 7% in rats.

  19. Fast quantification of endogenous carbohydrates in plasma using hydrophilic interaction liquid chromatography coupled with tandem mass spectrometry.

    Science.gov (United States)

    Zhu, Bangjie; Liu, Feng; Li, Xituo; Wang, Yan; Gu, Xue; Dai, Jieyu; Wang, Guiming; Cheng, Yu; Yan, Chao

    2015-01-01

    Endogenous carbohydrates in biosamples are frequently highlighted as the most differential metabolites in many metabolomics studies. A simple, fast, simultaneous quantitative method for 16 endogenous carbohydrates in plasma has been developed using hydrophilic interaction liquid chromatography coupled with tandem mass spectrometry. In order to quantify 16 endogenous carbohydrates in plasma, various conditions, including columns, chromatographic conditions, mass spectrometry conditions, and plasma preparation methods, were investigated. Different conditions in this quantified analysis were performed and optimized. The reproducibility, precision, recovery, matrix effect, and stability of the method were verified. The results indicated that a methanol/acetonitrile (50:50, v/v) mixture could effectively and reproducibly precipitate rat plasma proteins. Cold organic solvents coupled with vortex for 1 min and incubated at -20°C for 20 min were the most optimal conditions for protein precipitation and extraction. The results, according to the linearity, recovery, precision, matrix effect, and stability, showed that the method was satisfactory in the quantification of endogenous carbohydrates in rat plasma. The quantified analysis of endogenous carbohydrates in rat plasma performed excellently in terms of sensitivity, high throughput, and simple sample preparation, which met the requirement of quantification in specific expanded metabolomic studies after the global metabolic profiling research. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Hydrophilic Interaction Liquid Chromatography-Tandem Mass Spectrometry Analysis of Fosetyl-Aluminum in Airborne Particulate Matter

    Directory of Open Access Journals (Sweden)

    Francesca Buiarelli

    2018-01-01

    Full Text Available Fosetyl-aluminum is a synthetic fungicide administered to plants especially to prevent diseases caused by the members of the Peronosporales and several Phytophthora species. Herein, we present a selective liquid chromatography-tandem mass spectrometry (LC-MS/MS method to analyze residues of fosetyl-A1 in air particulate matter. This study was performed in perspective of an exposure assessment of this substance of health concern in environments where high levels of fosetly-Al, relatively to airborne particulate matter, can be found after spraying it. The cleanup procedure of the analyte, from sampled filters of atmospheric particulate matter, was optimized using a Strata X solid-phase extraction cartridge, after accelerated extraction by using water. The chromatographic separation was achieved using a polymeric column based on hydrophilic interaction in step elution with water/acetonitrile, whereas the mass spectrometric detection was performed in negative electrospray ionization. The proposed method resulted to be a simple, fast, and suitable method for confirmation purposes.

  1. High-sensitivity simultaneous liquid chromatography-tandem mass spectrometry assay of ethinyl estradiol and levonorgestrel in human plasma

    Institute of Scientific and Technical Information of China (English)

    Abhishek Gandhi; Swati Guttikar; Priti Trivedi

    2015-01-01

    A sensitive and simultaneous liquid chromatography-tandem mass spectrometry method was developed and validated for quantification of ethinyl estradiol and levonorgestrel. The analytes were extracted with methyl-tert-butyl ether: n-hexane (50:50, v/v) solvent mixture, followed by dansyl derivatization. The chromatographic separation was performed on a Kinetex C18 (50 mm × 4.6 mm, 2.6μm) column with a mobile phase of 0.1% (v/v) formic acid in water and acetonitrile in gradient composition. The mass transitions were monitored in electrospray positive ionization mode. The assay exhibited a linear range of 0.100-20.0 ng/mL for levonorgestrel and 4.00-500 pg/mL for ethinyl estradiol in human plasma. A run time of 9.0 min for each sample made it possible to analyze a throughput of more than 100 samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic and bioequivalence studies.

  2. Simultaneous determination of zolazepam and tiletamine in dog plasma by liquid chromatography coupled to a tandem mass spectrometry.

    Science.gov (United States)

    Noh, Kyeumhan; Kim, Kil-Soo; Ahn, Byoungki; Archimbault, Pillippe; Oh, Tae-Ho; Kang, Wonku

    2012-10-01

    A mixture of tiletamine, a dissociative anesthetic, and zolazepam, a minor tranquilizer, has been widely used as an anesthetic or an immobilizing agent in a variety of animal species. However, interestingly, their pharmacokinetic behaviors have been published only in polar bears and pigs. In this study, we introduce a sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for determining the two drugs in dog plasma. After simple protein precipitation with acetonitrile including midazolam (internal standard), the analytes were chromatographed on a reversed-phase column with a mobile phase of 10 m m ammonium acetate aqueous solution and acetonitrile (1:4, v/v). The accuracy and precision of the assay were in accordance with FDA regulations for the validation of bioanalytical methods. This method was used to measure the concentrations of zolazepam and tiletamine in plasma after a single intramuscular 10 mg dose of each in beagle dogs. Copyright © 2012 John Wiley & Sons, Ltd.

  3. A liquid chromatography with tandem mass spectrometry method for quantitating total and unbound ceritinib in patient plasma and brain tumor

    Directory of Open Access Journals (Sweden)

    Xun Bao

    2018-02-01

    Full Text Available A rapid, sensitive, and robust reversed-phase liquid chromatography with tandem mass spectrometry method was developed and validated for the determination of total and unbound ceritinib, a second-generation ALK inhibitor, in patient plasma and brain tumor tissue samples. Sample preparation involved simple protein precipitation with acetonitrile. Chromatographic separation was achieved on a Waters ACQUITY UPLC BEH C18 column using a 4-min gradient elution consisting of mobile phase A (0.1% formic acid in water and mobile phase B (0.1% formic acid in acetonitrile, at a flow rate of 0.4 mL/min. Ceritinib and the internal standard ([13C6]ceritinib were monitored using multiple reaction monitoring mode under positive electrospray ionization. The lower limit of quantitation (LLOQ was 1 nM of ceritinib in plasma. The calibration curve was linear over ceritinib concentration range of 1–2000 nM in plasma. The intra- and inter-day precision and accuracy were within the generally accepted criteria for bioanalytical method (<15%. The method was successfully applied to assess ceritinib brain tumor penetration, as assessed by the unbound drug brain concentration to unbound drug plasma concentration ratio, in patients with brain tumors.

  4. Validation and application of a high-performance liquid chromatography--tandem mass spectrometry assay for mosapride in human plasma.

    Science.gov (United States)

    Ramakrishna, N V S; Vishwottam, K N; Manoj, S; Koteshwara, M; Chidambara, J; Varma, D P

    2005-09-01

    A simple, rapid, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed and validated for quantification of mosapride (I), a novel and potent gastroprokinetic agent that enhances the upper gastrointestinal motility by stimulating 5-HT(4) receptor. The analyte and internal standard, tamsulosin (II), were extracted by liquid-liquid extraction with diethyl ether-dichloromethane (70:30, v/v) using a Glas-Col Multi-Pulse Vortexer. The chromatographic separation was performed on a reversed-phase Waters symmetry C(18) column with a mobile phase of 0.03% formic acid-acetonitrile (10:90, v/v). The protonated analyte was quantitated in positive ionization by multiple reaction monitoring with a mass spectrometer. The mass transitions m/z 422.3 -->198.3 and m/z 409.1 -->228.1 were used to measure I and II, respectively. The assay exhibited a linear dynamic range of 0.5-100.0 ng/mL for mosapride in human plasma. The lower limit of quantitation was 500 pg/mL with a relative standard deviation of less than 15%. Acceptable precision and accuracy were obtained for concentrations over the standard curve ranges. A run time of 2.0 min for each sample made it possible to analyze a throughput of more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies. Copyright (c) 2005 John Wiley & Sons, Ltd.

  5. Investigating the Effect of Column Geometry on Separation Efficiency using 3D Printed Liquid Chromatographic Columns Containing Polymer Monolithic Phases.

    Science.gov (United States)

    Gupta, Vipul; Beirne, Stephen; Nesterenko, Pavel N; Paull, Brett

    2018-01-16

    Effect of column geometry on the liquid chromatographic separations using 3D printed liquid chromatographic columns with in-column polymerized monoliths has been studied. Three different liquid chromatographic columns were designed and 3D printed in titanium as 2D serpentine, 3D spiral, and 3D serpentine columns, of equal length and i.d. Successful in-column thermal polymerization of mechanically stable poly(BuMA-co-EDMA) monoliths was achieved within each design without any significant structural differences between phases. Van Deemter plots indicated higher efficiencies for the 3D serpentine chromatographic columns with higher aspect ratio turns at higher linear velocities and smaller analysis times as compared to their counterpart columns with lower aspect ratio turns. Computational fluid dynamic simulations of a basic monolithic structure indicated 44%, 90%, 100%, and 118% higher flow through narrow channels in the curved monolithic configuration as compared to the straight monolithic configuration at linear velocities of 1, 2.5, 5, and 10 mm s -1 , respectively. Isocratic RPLC separations with the 3D serpentine column resulted in an average 23% and 245% (8 solutes) increase in the number of theoretical plates as compared to the 3D spiral and 2D serpentine columns, respectively. Gradient RPLC separations with the 3D serpentine column resulted in an average 15% and 82% (8 solutes) increase in the peak capacity as compared to the 3D spiral and 2D serpentine columns, respectively. Use of the 3D serpentine column at a higher flow rate, as compared to the 3D spiral column, provided a 58% reduction in the analysis time and 74% increase in the peak capacity for the isocratic separations of the small molecules and the gradient separations of proteins, respectively.

  6. Liquid chromatographic determination of para-toluenesulfonamide in edible fillet tissues from three species of fish

    Science.gov (United States)

    Meinertz, J.R.; Schmidt, L.J.; Stehly, G.R.; Gingerich, W.H.

    1999-01-01

    Chloramine-T (N-sodium-N-chloro-p-toluene-sulfonamide) is a candidate therapeutic drug for treating bacterial gill disease, a predominant disease of a variety of fish species. Research has been initiated to obtain the U.S. Food and Drug Administration's (FDA) approval for the use of chloramine-T on a variety of fish species. An attribute of a therapeutic aquaculture drug that must be characterized before the FDA approves its use is depletion of the drug's marker residue (the drug's parent compound or metabolite of highest concentration in an edible tissue). Para-Toluenesulfonamide (p-TSA) is the primary degradation product and marker residue for chloramine-T in rainbow trout. To conduct residue depletion studies for chloramine-T in fish, a robust analytical method sensitive and specific for p-TSA residues in edible fillet tissue from a variety of fish was required. Homogenized fillet tissues from rainbow trout (Oncorhynchus mykiss), walleye (Stizostedion vitreum), and channel catfish (Ictalurus punctatus) were fortified at nominal p-TSA concentrations of 17, 67, 200, 333, and 1000 ng/g. Samples were analyzed by isocratic reversed-phase liquid chromatography (LC) with absorbance detection at 226 nm. Mean recoveries of p-TSA ranged from 77 to 93.17%; relative standard deviations ranged from 1.5 to 14%; method quantitation limits ranged from 13 to 18 ng/g; and method detection limits ranged from 3.8 to 5.2 ng/g. The LC parameters produced p-TSA peaks without coelution of endogenous compounds and excluded chromatographic interference from at least 20 chemicals and drugs of potential use in aquaculture.

  7. Liquid chromatographic determination of CPZEN-45, a novel anti-tubercular drug, in biological samples.

    Science.gov (United States)

    Hanif, S N M; Hickey, A J; Garcia-Contreras, L

    2014-01-01

    CPZEN-45 is a new drug candidate being considered for the treatment of tuberculosis (TB). The aim of this study was to develop and validate a reverse-phase high-performance liquid chromatographic (HPLC) method suitable to determine CPZEN-45 concentrations in biological samples. CPZEN-45 was extracted from biological fluids and tissues (plasma, lung and spleen from guinea pig) by sequential extraction with acetonitrile and quantified by a Waters HPLC Alliance System coupled with a ZORBAX Bonus-RP column, guard column and UV detection at 263nm. The mobile phase was 20:80 acetonitrile:ultrapure-water with 0.05% TFA. The CPZEN-45 peak was eluted at 5.1min with no interference from the inherent peaks of plasma, bronchoalveolar lavage (BAL), lung or spleen tissues. Recovery of CPZEN-45 from biological samples was >96% of the spiked amount. The limit of detection was 0.05μg/ml and the limit of quantitation was 0.29μg/ml which was more than 5 and 21 times lower than the reported minimal inhibitory concentration of CPZEN-45 (MIC=1.56μg/ml for Mycobacterium tuberculosis and 6.25μg/ml for MDR-TB, respectively). Thus, HPLC method was deemed reliable, sensitive, reproducible and accurate for the determination of CPZEN-45 concentrations in plasma, BAL, lung and spleen tissues. Therefore, this method was used in subsequent studies in the guinea pig model to determine the disposition of CPZEN-45 after administration of solutions by the IV and SC routes. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Measurement of total and free docetaxel concentration in human plasma by ultra-performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Rigo-Bonnin, Raül; Cobo-Sacristán, Sara; Gonzalo-Diego, Núria; Colom, Helena; Muñoz-Sánchez, Carmen; Urruticoechea, Ander; Falo, Catalina; Alía, Pedro

    2016-01-05

    Docetaxel is a semi-synthetic taxane with cytotoxic anti-neoplastic activity and, currently used as anticancer agent in several types of cancer. Docetaxel is highly bound to plasma proteins, and this significantly determines its clearance and activity. Therefore, measurement of free docetaxel in plasma is pharmacologically important when pharmacokinetics is investigated. We developed and validated chromatographic methods by ultra-performance liquid chromatography-tandem mass spectrometry to measure total and free docetaxel concentration in human plasma. The final validated methods involved liquid-liquid extraction followed by dryness under nitrogen evaporation. To measure free docetaxel concentration, sample preparation was preceded by ultrafiltration. Chromatographic separation was achieved using an Acquity(®) UPLC(®) BEH™ (2.1×100 mm id, 1.7 μm) reverse-phase C18 column at a flow rate of 0.4 mL/min, using isocratic elution mode containing ammonium acetate/formic acid in water/methanol (30:70 v/v) as mobile phase. Docetaxel and its internal standard (paclitaxel) were detected by electrospray ionization mass spectrometry in positive ion multiple reaction monitoring mode using mass-to-charge (m/z) transitions of 808.3→527.0 (quantifier) and 808.3→509.0 (qualifier); and 854.3→569.0 (quantifier) and 854,3→509,0 (qualifier), respectively. The run time per sample was 3.5 min. The limits of quantification were 1,95 and 0.42 μg/L and linearity was observed between 1.95 and 1000 and 0.42-100 μg/L for total and free docetaxel, respectively. Coefficients of variation and absolute relative biases were less than 13.8% and 10.0%. Recovery values were greater than 79.4%. Evaluation of the matrix effect showed ion suppression and no carry-over was observed. The validated methods could be useful for both therapeutic drug monitoring and pharmacokinetic studies. They could be applied to daily clinical laboratory practice to measure the concentration of total and free

  9. Derivatization reactions in the gas—liquid chromatographic analysis of drugs in biological fluids

    NARCIS (Netherlands)

    Hulshoff, A.; Lingeman, H.

    1984-01-01

    Alkylation, acylation, silylation and other derivatization reactions applied to the gas chromatographic analysis of drugs in biological matrices are reviewed. Reaction conditions are discussed in relation to reaction mechanisms. Detector-oriented labelling of drugs, and derivatization with chiral

  10. Core-shell in liquid chromatography: application for determining sulphonamides in feed and meat using conventional chromatographic systems

    Directory of Open Access Journals (Sweden)

    Antonio Armentano

    2016-12-01

    Full Text Available A C18 column packed with core-shell particles was used for the chromatographic separation of sulphonamides in feed and meat by a conventional high performance liquid chromatography system coupled with a diode array detector. Two analytical methods, already used in our laboratory, have been modified without any changes in the extraction and clean-up steps and in the liquid chromatography instrumentation. Chromatographic conditions applied on a traditional 5-μm column have been optimized on a column packed with 2.6 μm core-shell particles. A binary mobile phase [acetate buffer solution at pH 4.50 and a mixture of methanol acetonitrile 50: 50 (v/v] was employed in gradient mode at the flow rate of 1.2 mL with an injection volume of 6 μL. These chromatographic conditions allow the separation of 13 sulphonamides with an entire run of 13 minutes. Preliminary studies have been carried out comparing blanks and spiked samples of feed and meat. A good resolution and the absence of interferences were achieved in chromatograms for both matrices. Since no change was made to the sample preparation, the optimized method does not require a complete revalidation and can be used to make routine analysis faster.

  11. Liquid Chromatography with Electrospray Ionization and Tandem Mass Spectrometry Applied in the Quantitative Analysis of Chitin-Derived Glucosamine for a Rapid Estimation of Fungal Biomass in Soil

    Directory of Open Access Journals (Sweden)

    Madelen A. Olofsson

    2016-01-01

    Full Text Available This method employs liquid chromatography-tandem mass spectrometry to rapidly quantify chitin-derived glucosamine for estimating fungal biomass. Analyte retention was achieved using hydrophilic interaction liquid chromatography, with a zwitter-ionic stationary phase (ZIC-HILIC, and isocratic elution using 60% 5 mM ammonium formate buffer (pH 3.0 and 40% ACN. Inclusion of muramic acid and its chromatographic separation from glucosamine enabled calculation of the bacterial contribution to the latter. Galactosamine, an isobaric isomer to glucosamine, found in significant amounts in soil samples, was also investigated. The two isomers form the same precursor and product ions and could not be chromatographically separated using this rapid method. Instead, glucosamine and galactosamine were distinguished mathematically, using the linear relationships describing the differences in product ion intensities for the two analytes. The m/z transitions of 180 → 72 and 180 → 84 were applied for the detection of glucosamine and galactosamine and that of 252 → 126 for muramic acid. Limits of detection were in the nanomolar range for all included analytes. The total analysis time was 6 min, providing a high sample throughput method.

  12. Development of Direct Reversed-Phase High Performance liquid chromatographic method for quantitative determination of gabapentin in pharmaceutical dosage

    International Nuclear Information System (INIS)

    Hassan, W.; Zaman, B.; Rahman, S.; Rahman, A.U.; Ali, N.; Mohammadzai, I.U.

    2012-01-01

    The objective of the present work was to develop and validate a rapid analytical method for quantitative determination of Gabapentin in pharmaceutical dosage tablets and capsules. An accurate, simple, and sensitive reversed-phase high performance liquid chromatographic (HPLC) method, UV detection at 215 nm and flow rate at 1.0 ml/min has been developed. Isocratic elution was used instead of gradient elution to reduce the time and cost of serial analysis. The mobile phase was a mixture of water and methanol (HPLC grade). The retention time (Rt) of Gabapentin was 4.681 +- 0.013 minutes. Recovery, Precision, accuracy, and linearity were determined for the stated method. The calibration curve was linear and the correlation coefficient was 0.9996. There was no chromatographic interference from other excipients present in dosage form. The method was validated appropriately and successfully used for determination of Gabapentin in Pharmaceutical formulations. (author)

  13. High-performance liquid chromatographic determination of isoniazid and 1-isonicotinyl-2-lactosylhydrazine in isoniazid tablet formulations.

    Science.gov (United States)

    Butterfield, A G; Lovering, E G; Sears, R W

    1980-02-01

    A high-performance liquid chromatographic procedure is presented for the simultaneous determination of isoniazid and 1-isonicotinyl-2-lactosylhydrazine (I) in isoniazid tablet formulations. An aliquot of a diluted aqueous tablet extract is introduced onto a microparticulate cyanopropyl bonded-phase column using a valve-loop injector and chromatographed using a mobile phase of acetonitrile--0.01 M, pH 3.5 aqueous acetate buffer (5:95). Compound I can be determined at levels as low as 0.5% of the isoniazid label claim. The relative standard deviations are 0.4 and 0.7% for the simultaneous determination of isoniazid and I, respectively. Seven commercial tablet formulations contained 93.8--97.0% of the labeled isoniazid amounts and 0.3--5.8% of I, expressed as equivalent isoniazid relative to the labeled isoniazid level.

  14. Validation of high-performance liquid chromatographic method for analysis of fluconazole in microemulsions and liquid crystals

    Directory of Open Access Journals (Sweden)

    Hilris Rocha e Silva

    2014-04-01

    Full Text Available In recent decades, there has been a significant increase in the incidence of fungal diseases. Certain fungal diseases cause cutaneous lesions and in the usual treatment, generally administred orally, the drug reaches the site of action with difficulty and its concentration is too low. An approach much explored in recent years is the development of nanotechnology-based drug delivery systems, and microemulsions (ME and liquid crystals (LC are promising. ME and LC were developed with oleic acid or copaiba oil as the oil phase, propoxyl (5OP ethoxyl (20 OE cetyl alcohol as surfactant and water. An analytical method to assess the incorporation of fluconazole (FLU in the systems under study was validated according to guidelines of the International Conference on Harmonization (ICH guidelines and the Brazilian Food, Drug and Sanitation Agency (ANVISA. The method was conducted on a C18-RP column (250 × 4.6 mm i.d., maintained at room temperature. The mobile phase consisted of acetonitrile and water (50:50, v/v, run at a flow rate of 1.0mL/min and using ultraviolet detection at 210nm. The chromatographic separation was obtained with a retention time of 6.3min, and was linear in the range of 20-400 µg/mL (r2=0.9999. The specificity showed no interference of the excipients. The accuracy was 100.76%. The limits of detection and quantitation were 0.057 and 0.172 µg.mL-1, respectively. Moreover, method validation demonstrated satisfactory results for precision and robustness. The proposed method was applied for the analysis of the incorporation of FLU in ME and LC, contributing to improve the quality control and to assure the therapeutic efficacy.

  15. Storing of Extracts in Polypropylene Microcentrifuge Tubes Yields Contaminant Peak During Ultra-flow Liquid Chromatographic Analysis.

    Science.gov (United States)

    Kshirsagar, Parthraj R; Hegde, Harsha; Pai, Sandeep R

    2016-05-01

    This study was designed to understand the effect of storage in polypropylene microcentrifuge tubes and glass vials during ultra-flow liquid chromatographic (UFLC) analysis. One ml of methanol was placed in polypropylene microcentrifuge tubes (PP material, Autoclavable) and glass vials (Borosilicate) separately for 1, 2, 4, 8, 10, 20, 40, and 80 days intervals stored at -4°C. Contaminant peak was detected in methanol stored in polypropylene microcentrifuge tubes using UFLC analysis. The contaminant peak detected was prominent, sharp detectable at 9.176 ± 0.138 min on a Waters 250-4.6 mm, 4 μ, Nova-Pak C18 column with mobile phase consisting of methanol:water (70:30). It was evident from the study that long-term storage of biological samples prepared using methanol in polypropylene microcentrifuge tubes produce contaminant peak. Further, this may mislead in future reporting an unnatural compound by researchers. Long-term storage of biological samples prepared using methanol in polypropylene microcentrifuge tubes produce contaminant peakContamination peak with higher area under the curve (609993) was obtained in ultra-flow liquid chromatographic run for methanol stored in PP microcentrifuge tubesContamination peak was detected at retention time 9.113 min with a lambda max of 220.38 nm and 300 mAU intensity on the given chromatographic conditionsGlass vials serve better option over PP microcentrifuge tubes for storing biological samples. Abbreviations used: UFLC: Ultra Flow Liquid Chromatography; LC: Liquid Chromatography; MS: Mass spectrometry; AUC: Area Under Curve.

  16. High-throughput method for macrolides and lincosamides antibiotics residues analysis in milk and muscle using a simple liquid-liquid extraction technique and liquid chromatography-electrospray-tandem mass spectrometry analysis (LC-MS/MS).

    Science.gov (United States)

    Jank, Louise; Martins, Magda Targa; Arsand, Juliana Bazzan; Campos Motta, Tanara Magalhães; Hoff, Rodrigo Barcellos; Barreto, Fabiano; Pizzolato, Tânia Mara

    2015-11-01

    A fast and simple method for residue analysis of the antibiotics classes of macrolides (erythromycin, azithromycin, tylosin, tilmicosin and spiramycin) and lincosamides (lincomycin and clindamycin) was developed and validated for cattle, swine and chicken muscle and for bovine milk. Sample preparation consists in a liquid-liquid extraction (LLE) with acetonitrile, followed by liquid chromatography-electrospray-tandem mass spectrometry analysis (LC-ESI-MS/MS), without the need of any additional clean-up steps. Chromatographic separation was achieved using a C18 column and a mobile phase composed by acidified acetonitrile and water. The method was fully validated according the criteria of the Commission Decision 2002/657/EC. Validation parameters such as limit of detection, limit of quantification, linearity, accuracy, repeatability, specificity, reproducibility, decision limit (CCα) and detection capability (CCβ) were evaluated. All calculated values met the established criteria. Reproducibility values, expressed as coefficient of variation, were all lower than 19.1%. Recoveries range from 60% to 107%. Limits of detection were from 5 to 25 µg kg(-1).The present method is able to be applied in routine analysis, with adequate time of analysis, low cost and a simple sample preparation protocol. Copyright © 2015. Published by Elsevier B.V.

  17. Ultrapressure liquid chromatography-tandem mass spectrometry assay using atmospheric pressure photoionization (UPLC-APPI-MS/MS) for quantification of 4-methoxydiphenylmethane in pharmacokinetic evaluation.

    Science.gov (United States)

    Farhan, Nashid; Fitzpatrick, Sean; Shim, Yun M; Paige, Mikell; Chow, Diana Shu-Lian

    2016-09-05

    4-Methoxydiphenylmethane (4-MDM), a selective augmenter of Leukotriene A4 Hydrolase (LTA4H), is a new anti-inflammatory compound for potential treatment of chronic obstructive pulmonary disease (COPD). Currently, there is no liquid chromatography tandem mass spectrometric (LC-MS/MS) method for the quantification of 4-MDM. A major barrier for developing the LC-MS/MS method is the inability of electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) to ionize 4-MDM due to its hydrophobicity and lack of any functional group for ionization. With the advent of atmospheric pressure photoionization (APPI) technique, many hydrophobic compounds have been demonstrated to ionize by charge transfer reactions. In this study, a highly sensitive ultrapressure liquid chromatography tandem mass spectrometry assay using atmospheric pressure photoionization (UPLC-APPI-MS/MS) for the quantifications of 4-MDM in rat plasma has been developed and validated. 4-MDM was extracted from the plasma by solid phase extraction (SPE) and separated chromatographically using a reverse phase C8 column. The photoionization (PI) was achieved by introducing anisole as a dopant to promote the reaction of charge transfer. The assay with a linear range of 5 (LLOQ)-400ngmL(-1) met the regulatory requirements for accuracy, precision and stability. The validated assay was employed to quantify the plasma concentrations of 4-MDM after an oral dosing in Sprague Dawley (SD) rats. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Quantitative analysis of a novel antimicrobial peptide in rat plasma by ultra performance liquid chromatography–tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Ruo-Wen Zhang

    2011-08-01

    Full Text Available We described the first results of a quantitative ultra performance liquid chromatography–tandem mass spectrometry method for a novel antimicrobial peptide (phylloseptin, PSN-1. Chromatographic separation was accomplished on a Waters bridged ethyl hybrid (BEH C18 (50 mm×2.1 mm, 1.7 μm column with acetonitrile–water (25:75, v/v as isocratic mobile phase. Mass spectrometry detection was performed in the positive electrospray ionization mode and by monitoring of the transitions at m/z 679.6/120, 509.6/120 (PSN-1 and m/z 340.7/165 (Thymopentin, IS. Protein precipitation was investigated and the recovery was satisfactory (above 82%. The method was shown to be reproducible and reliable with intra-day precision below 5.3%, inter-day precision below 14.2%, and linear range from 0.02 to 2 μg/mL with r>0.994. The method was successfully applied to a pharmacokinetic study of PSN-1 in rats after intravenous administration. Keywords: Antimicrobial peptide, Phylloseptin, Ultra performance liquid chromatography–tandem mass spectrometry, Pharmacokinetic

  19. In-syringe dispersive liquid-liquid microextraction with liquid chromatographic determination of synthetic pyrethroids in surface water

    Directory of Open Access Journals (Sweden)

    Saeed S. Albaseer

    2012-03-01

    Full Text Available An indigenously fabricated in laboratory glass syringe was used for in-syringe dispersive liquid-liquid microextraction (is-DLLME and preconcentration of synthetic pyrethroids (SPs from surface waters suitable for their determination by high performance liquid chromatography. In contrast to classical DLLME, is-DLLME allows the use of lighter-than-water organic solvents and the analysis of environmental contaminants’ samples without prior filtration, which is of great importance due to the high affinity of pyrethroids to adsorb to solid particulates present in environmental samples. The effects of various parameters on the extraction efficiency were evaluated and optimized systemically using one-factor-at-a-time method (OFAT and statistically using full factorial design (24. Three SPs (viz.; cypermethrin, resmethrin and permethrin were analyzed. The method showed good accuracy with RSD% in the range of of 4.8–6.9%. The method detection limits of the three pesticides ranged from 0.14 to 0.16 ng mL-1. The proposed method was applied for the determination of synthetic pyrethroids in lake water

  20. New ultra-performance liquid chromatography-tandem mass spectrometry method for the determination of irbesartan in human plasma

    Directory of Open Access Journals (Sweden)

    Tanveer A. Wani

    2015-09-01

    Full Text Available With the objective of reducing analysis time and maintaining good efficiency, there has been substantial focus on high-speed chromatographic separations and ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS is a preeminent analytical tool for rapid biomedical analysis. In this study a simple, rapid, sensitive, and specific ultra-performance liquid chromatography-MS/MS method was developed and validated for quantification of the angiotensin II receptor antagonist, irbesartan (IRB, in human plasma. After a simple protein precipitation using methanol and acetonitrile, IRB and internal standard (IS telmisartan were separated on Acquity UPLC BEH C18 column (50 mm × 2.1 mm, i.d. 1.7 μm, Waters, Milford, MA, USA using a mobile phase consisted of acetonitrile: methanol: 10 mM ammonium acetate (70: 15: 15 v/v/v with a flow rate of 0.4 mL/min and detected MS/MS in negative ion mode. The ion transitions recorded in multiple reaction monitoring mode were m/z 427.2→193.08 for IRB and m/z 513.2→469.3 for IS. The assay exhibited a linear dynamic range of 2–500 ng/mL for IRB in human plasma with good correlation coefficient of (0.995 and with a lower limit of quantitation of 2 ng/mL. The intra- and interassay precisions were satisfactory; the relative standard deviations did not exceed 9.91%. The proposed UPLC-MS/MS method is simple, rapid, and highly sensitive, and hence it could be reliable for pharmacokinetic and toxicokinetic study in both animals and humans.

  1. Profiling ABA metabolites in Nicotiana tabacum L. leaves by ultra-performance liquid chromatography-electrospray tandem mass spectrometry.

    Science.gov (United States)

    Turecková, Veronika; Novák, Ondrej; Strnad, Miroslav

    2009-11-15

    We have developed a simple method for extracting and purifying (+)-abscisic acid (ABA) and eight ABA metabolites--phaseic acid (PA), dihydrophaseic acid (DPA), neophaseic acid (neoPA), ABA-glucose ester (ABAGE), 7'-hydroxy-ABA (7'-OH-ABA), 9'-hydroxy-ABA (9'-OH-ABA), ABAaldehyde, and ABAalcohol--before analysis by a novel technique for these substances, ultra-performance liquid chromatography-electrospray ionisation tandem mass spectrometry (UPLC-ESI-MS/MS). The procedure includes addition of deuterium-labelled standards, extraction with methanol-water-acetic acid (10:89:1, v/v), simple purification by Oasis((R)) HLB cartridges, rapid chromatographic separation by UPLC, and sensitive, accurate quantification by MS/MS in multiple reaction monitoring modes. The detection limits of the technique ranged between 0.1 and 1 pmol for ABAGE and ABA acids in negative ion mode, and 0.01-0.50 pmol for ABAGE, ABAaldehyde, ABAalcohol and the methylated acids in positive ion mode. The fast liquid chromatographic separation and analysis of ABA and its eight measured derivatives by UPLC-ESI-MS/MS provide rapid, accurate and robust quantification of most of the substances, and the low detection limits allow small amounts of tissue (1-5mg) to be used in quantitative analysis. To demonstrate the potential of the technique, we isolated ABA and its metabolites from control and water-stressed tobacco leaf tissues then analysed them by UPLC-ESI-MS/MS. Only ABA, PA, DPA, neoPA, and ABAGE were detected in the samples. PA was the most abundant analyte (ca. 1000 pmol/g f.w.) in both the control and water-stressed tissues, followed by ABAGE and DPA, which were both present at levels ca. 5-fold lower. ABA levels were at least 100-fold lower than PA concentrations, but they increased following the water stress treatment, while ABAGE, PA, and DPA levels decreased. Overall, the technique offers substantial improvements over previously described methods, enabling the detailed, direct study of

  2. Development and evaluation of a liquid chromatography tandem mass spectrometry method for simultaneous determination of salivary melatonin, cortisol and testosterone

    DEFF Research Database (Denmark)

    Jensen, Marie Aarrebo; Hansen, Åse Marie; Abrahamsson, Peter

    2011-01-01

    saliva. We used liquid-liquid extraction (LLE) followed by liquid chromatography coupled to electrospray tandem mass spectrometry (LC-ESI-MS/MS) recorded in positive ion mode. Saliva samples were collected by spitting directly into tubes and 250 µL were used for analysis. The limits of detection were 4...

  3. Updated reference design of a liquid metal cooled tandem mirror fusion breeder

    Energy Technology Data Exchange (ETDEWEB)

    Berwald, D.H.; Whitley, R.H.; Garner, J.K.; Gromada, R.J.; McCarville, T.J.; Moir, R.W.; Lee, J.D.; Bandini, B.R.; Fulton, F.J.; Wong, C.P.C.; Maya, I.; Hoot, C.G.; Schultz, K.R.; Miller, L.G.; Beeston, J.M.; Harris, B.L.; Westman, R.A.; Ghoniem, N.M.; Orient, G.; Wolfer, M.; DeVan, J.H.; Torterelli, P.

    1985-09-01

    Detailed studies of key techinical issues for liquid metal cooled fusion breeder (fusion-fission hybrid blankets) have been performed during the period 1983-4. Based upon the results of these studies, the 1982 reference liquid metal cooled tandem mirror fusion breeder blanket design was updated and is described. The updated reference blankets provides increased breeding and lower technological risk in comparison with the original reference blanket. In addition to the blanket design revisions, a plant concept, cost, and fuel cycle economics assessment is provided. The fusion breeder continues to promise an economical source of fissile fuel for the indefinite future.

  4. Updated reference design of a liquid metal cooled tandem mirror fusion breeder

    International Nuclear Information System (INIS)

    Berwald, D.H.; Whitley, R.H.; Garner, J.K.

    1985-09-01

    Detailed studies of key techinical issues for liquid metal cooled fusion breeder (fusion-fission hybrid blankets) have been performed during the period 1983-4. Based upon the results of these studies, the 1982 reference liquid metal cooled tandem mirror fusion breeder blanket design was updated and is described. The updated reference blankets provides increased breeding and lower technological risk in comparison with the original reference blanket. In addition to the blanket design revisions, a plant concept, cost, and fuel cycle economics assessment is provided. The fusion breeder continues to promise an economical source of fissile fuel for the indefinite future

  5. Liquid chromatography-tandem mass spectrometric assay for the tyrosine kinase inhibitor afatinib in mouse plasma using salting-out liquid-liquid extraction

    NARCIS (Netherlands)

    Sparidans, Rolf W; van Hoppe, Stephanie; Rood, Johannes J M; Schinkel, Alfred H; Schellens, Jan H M; Beijnen, Jos H

    2016-01-01

    A quantitative bioanalytical liquid chromatography-tandem mass spectrometric (LC-MS/MS) assay for afatinib, an irreversible inhibitor of the ErbB (erythroblastic leukemia viral oncogene homolog) tyrosine kinase family, was developed and validated. Plasma samples were pre-treated using salting-out

  6. High performance liquid chromatographic separation of polycyclic aromatic hydrocarbons on microparticulate pyrrolidone and application to the analysis of shale oil

    International Nuclear Information System (INIS)

    Mourey, T.H.; Siggia, S.; Uden, P.C.; Crowley, R.J.

    1980-01-01

    A chemically bonded pyrrolidone substrate is used for the high performance liquid chromatographic separation of polycyclic aromatic hydrocarbons. The cyclic amide phase interacts electronically with the polycyclic aromatic hydrocarbons in both the normal and reversed phase modes. Separation is effected according to the number of aromatic rings and the type of ring condensation. Information obtained is very different from that observed on hydrocarbon substrates, and thus these phases can be used in a complementary fashion to give a profile of polycyclic aromatics in shale oil samples. 7 figures, 1 table

  7. Liquid chromatography tandem mass spectrometry determination of total budesonide levels in dog plasma after inhalation exposure.

    Science.gov (United States)

    Berg, Seija; Melamies, Marika; Rajamäki, Minna; Vainio, Outi; Peltonen, Kimmo

    2012-01-01

    A sensitive and selective method to quantify budesonide in dog plasma samples was developed and fully validated. Liquid-liquid extraction was followed by solid-phase extraction and liquid chromatography-tandem mass spectrometry with electrospray ionization. After reconstitution of the analytes in the mobile phase, samples were analysed by reversed-phase liquid chromatography with isocratic elution. d8-Budesonide was used as an internal standard, and characteristic transitions of d8-budesonide and budesonide were used for quantification. The method was validated with respect to selectivity, specificity, linearity, recovery, repeatability, reproducibility and limits of detection and quantification. The validated method was successfully applied to monitor the plasma levels of budesonide in dogs exposed to clinical doses of inhaled and intravenous drug.

  8. Determination of parabens in serum by liquid chromatography-tandem mass spectrometry: Correlation with lipstick use.

    Science.gov (United States)

    Tahan, Gabriella Padovani; Santos, Nayara de Kássia Souza; Albuquerque, Ana Carolina; Martins, Isarita

    2016-08-01

    Parabens are the most widely used preservative and are considered to be relatively safe compounds. However, studies have demonstrated that they may have estrogenic activity, and there is ongoing debate regarding the safety and potential cancer risk of using products containing these compounds. In the present work, liquid chromatography-tandem mass spectrometry was applied to determine methylparaben and propylparaben concentrations in serum, and the results were correlated with lipstick application. Samples were analyzed using liquid-liquid extraction, followed by liquid chromatography-tandem mass spectrometry. The validation results demonstrated the linearity of the method over a range of 1-20 ng/mL, in addition to the method's precision and accuracy. A statistically significant difference was demonstrated between serum parabens in women who used lipstick containing these substances compared with those not using this cosmetic (p = 0.0005 and 0.0016, respectively), and a strong association was observed between serum parabens and lipstick use (Spearman correlation = 0.7202). Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Ultra high performance liquid chromatography-electrospray ionization-tandem mass spectrometry screening method for direct analysis of designer drugs, "spice" and stimulants in oral fluid.

    Science.gov (United States)

    Strano-Rossi, Sabina; Anzillotti, Luca; Castrignanò, Erika; Romolo, Francesco Saverio; Chiarotti, Marcello

    2012-10-05

    An ultra high performance liquid chromatography-electrospray ionization-tandem mass spectrometry (UHPLC-ESI-MS/MS) screening method for the direct analysis in oral fluid (OF) of 24 drugs, including new synthetic cannabinoids and so-called "smart" designer drugs, in a single chromatographic run was set up. Benzylpiperazine, methylone, 5,6-methylenedioxy-2-aminoindane (MDAI), fenproporex, 4-fluoroamphetamine (4-FA), 4-methyl-N-ethylcathinone (4-MEC), 4-methylamphetamine (4-MA), methylbenzodioxolylbutanamine (MBDB), mephedrone, methylthioamphetamine (MTA), methylenedioxypyrovalerone (MDPV), mefenorex, nabilone, furfenorex, clobenzorex, JWH-200, AM 694, JWH-250, JWH-073, JWH-018, JWH-019, JWH-122, HU 210 and CP 47497 were determined in a chromatographic run of 9 min only with no sample pre-treatment, after addition of ISs and dilution in mobile phase A. This method is designed to be applied to 250 μL of OF sample, anyway is suitable to be used on smaller volumes (till 100 μL). LODs vary from 1ng/mL to 20 ng/mL. No interfering peaks were observed due to similar analytes, common therapeutic drugs or endogenous compounds. Matrix effect, although present especially for mephedrone, is acceptable, allowing the detection of the compounds at the LODs described. The developed method was applied on 400 real OF samples from on-site tests performed by police officers. Copyright © 2012 Elsevier B.V. All rights reserved.

  10. A simple and rapid ultra-high-performance liquid chromatography-tandem mass spectrometry method to determine plasma biotin in hemodialysis patients.

    Science.gov (United States)

    Yagi, Shigeaki; Nishizawa, Manabu; Ando, Itiro; Oguma, Shiro; Sato, Emiko; Imai, Yutaka; Fujiwara, Masako

    2016-08-01

    A simple, rapid, and selective method for determination of plasma biotin was developed using ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). After single-step protein precipitation with methanol, biotin and stable isotope-labeled biotin as an internal standard (IS) were chromatographed on a pentafluorophenyl stationary-phase column (2.1 × 100 mm, 2.7 μm) under isocratic conditions using 10 mm ammonium formate-acetonitrile (93:7, v/v) at a flow rate of 0.6 mL/min. The total chromatographic runtime was 5 min for each injection. Detection was performed in a positive electrospray ionization mode by monitoring selected ion transitions at m/z 245.1/227.0 and 249.1/231.0 for biotin and the IS, respectively. The calibration curve was linear in the range of 0.05-2 ng/mL using 300 μL of plasma. The intra- and inter-day precisions were all biotin concentrations in hemodialysis patients. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  11. Simultaneous quantitative analysis of eight vitamin D analogues in milk using liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Gomes, Fabio P; Shaw, P Nicholas; Whitfield, Karen; Hewavitharana, Amitha K

    2015-09-03

    Milk is an important source of nutrients for various risk populations, including infants. The accurate measurement of vitamin D in milk is necessary to provide adequate supplementation advice for risk groups and to monitor regulatory compliance. Currently used liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods are capable of measuring only four analogues of vitamin D in unfortified milk. We report here an accurate quantitative analytical method for eight analogues of vitamin D: Vitamin D2 and D3 (D2 and D3), 25-hydroxy D2 and D3, 24,25-dihydroxy D2 and D3, and 1,25-dihydroxyD2 and D3. In this study, we compared saponification and protein precipitation for the extraction of vitamin D from milk and found the latter to be more effective. We also optimised the pre-column derivatisation using 4-phenyl-l,2,4-triazoline-3,5-dione (PTAD), to achieve the highest sensitivity and accuracy for all major vitamin D forms in milk. Chromatography was optimised to reduce matrix effects such as ion-suppression, and the matrix effects were eliminated using co-eluting stable isotope labelled internal standards for the calibration of each analogue. The analogues, 25-hydroxyD3 (25(OH)D3) and its epimer (3-epi-25(OH)D3) were chromatographically resolved, to prevent over-estimation of 25(OH)D3. The method was validated and subsequently applied for the measurement of total vitamin D levels in human, cow, mare, goat and sheep milk samples. The detection limits, repeatability standard deviations, and recovery ranges were from 0.2 to 0.4 femtomols, 6.30-13.5%, and 88.2-105%, respectively. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Determination of endocrine-disrupting compounds in drinking waters by fast liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Magi, Emanuele; Scapolla, Carlo; Di Carro, Marina; Liscio, Camilla

    2010-09-01

    Growing attention has been recently paid to safety of food and drinking water, making necessary the adoption of policies for water sources protection and the development of sensitive and rapid analytical methods to identify micropollutants. Endocrine-disrupting compounds (EDCs) have emerged as a major issue as they alter the functioning of the endocrine system. Since ingestion of EDCs via food is considered the major exposure route, there is a growing interest in understanding EDC fate during drinking water treatment and in monitoring potential contamination of surface waters and groundwaters. In this work, a fast liquid chromatography-electrospray ionization-tandem mass spectrometry method was developed for the determination of 4-n-nonylphenol (NP), bisphenol A (BPA), estrone (E1), 17β-estradiol (E2) and 17α-ethinylestradiol (EE2) in drinking waters. In the literature analytical articles seldom provide details regarding fragmentation pathways. In this paper spectra of the five EDCs in negative ESI were interpreted with the support of accurate mass spectra acquired by a quadrupole time-of-flight instrument; fragmentation pathways were also proposed. The chromatographic separation of EDCs was optimized on a Pinnacle DB Biphenylic column with a water-acetonitrile gradient. Quantitative analysis was performed in multiple reaction monitoring (MRM) mode using bisphenol A-d(16) (BPA-d(16)) as internal standard; calibration curves showed good correlation coefficients (0.9989-0.9997). All figures of merit of the method were satisfactory; limits of detection were in the range 0.2-0.4 ng/ml. The method was applied to the determination of the analytes in waters sampled by polar organic chemical integrative samplers in a drinking water treatment plant. Rather low concentration of BPA, NP and E1 were measured in the inlet, while none of the considered EDCs was detected in the outlet. 2010 John Wiley & Sons, Ltd.

  13. On-line liquid chromatography/tandem mass spectrometry simultaneous determination of opiates, cocainics and amphetamines in dried blood spots.

    Science.gov (United States)

    Saussereau, E; Lacroix, C; Gaulier, J M; Goulle, J P

    2012-02-15

    A novel approach has been developed for the illicit drugs quantitative determination using dried blood spots (DBS) on filter paper. The illicit drugs tested were opiates (morphine and its 3- and 6-glucuronide metabolites, codeine, 6-monoacetylmorphine), cocainics (ecgonine methylester, benzoylecgonine, cocaine, cocaethylene) and amphetamines (amphetamine, methamphetamine, MDA, MDMA, MDEA). The described method, requiring a small blood volume, is based on high performance liquid chromatography coupled to tandem mass spectrometry using on-line extraction. A Whatman card 903 was spotted with 30μL of whole blood and left overnight to dry at room temperature. A 3-mm diameter disk was removed using a manual punch, suspended in 150μL of water for 10min with ultrasonication, and then 100μL was injected in the on-line LC-MS/MS system. An Oasis HLB was used as an extraction column and a C18 Atlantis as an analytical column. The chromatographic cycle was performed with 20mM ammonium formate buffer (pH 2.8) (solvent A) and acetonitrile/solvent A (90:10, v/v) gradient in 16min. Detection was performed in positive electrospray ionization mode (ESI+) with a Quattro Micro (Waters). Recoveries of all analytes were up to 80%. DBS were stored in duplicate at 4°C and -20°C for up to 6 months. Illicit drugs seemed to be much more stabled at -20°C. Furthermore, it was tested whether analysis of DBS may be as reliable as that of whole blood investigating authentic samples; significant correlations were obtained. This DBS assay has potential as rapid, sensitive and inexpensive option for the illicit drugs determination in small blood volumes, which seems of great interest in suspected cases of driving under the influence of drugs. Copyright © 2011 Elsevier B.V. All rights reserved.

  14. Comparison of core-shell and totally porous ultra high performance liquid chromatographic stationary phases based on their selectivity towards alfuzosin compounds.

    Science.gov (United States)

    Szulfer, Jarosław; Plenis, Alina; Bączek, Tomasz

    2014-06-13

    This paper focuses on the application of a column classification system based on the Katholieke Universiteit Leuven for the characterization of physicochemical properties of core-shell and ultra-high performance liquid chromatographic stationary phases, followed by the verification of the reliability of the obtained column classification in pharmaceutical practice. In the study, 7 stationary phases produced in core-shell technology and 18 ultra-high performance liquid chromatographic columns were chromatographically tested, and ranking lists were built on the FKUL-values calculated against two selected reference columns. In the column performance test, an analysis of alfuzosin in the presence of related substances was carried out using the brands of the stationary phases with the highest ranking positions. Next, a system suitability test as described by the European Pharmacopoeia monograph was performed. Moreover, a study was also performed to achieve a purposeful shortening of the analysis time of the compounds of interest using the selected stationary phases. Finally, it was checked whether methods using core-shell and ultra-high performance liquid chromatographic columns can be an interesting alternative to the high-performance liquid chromatographic method for the analysis of alfuzosin in pharmaceutical practice. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Functionalized graphene quantum dots loaded with free radicals combined with liquid chromatography and tandem mass spectrometry to screen radical scavenging natural antioxidants from Licorice and Scutellariae.

    Science.gov (United States)

    Wang, Guoying; Niu, XiuLi; Shi, Gaofeng; Chen, Xuefu; Yao, Ruixing; Chen, Fuwen

    2014-12-01

    A novel screening method was developed for the detection and identification of radical scavenging natural antioxidants based on a free radical reaction combined with liquid chromatography with tandem mass spectrometry. Functionalized graphene quantum dots were prepared for loading free radicals in the complex screening system. The detection was performed with and without a preliminary exposure of the samples to specific free radicals on the functionalized graphene quantum dots, which can facilitate charge transfer between free radicals and antioxidants. The difference in chromatographic peak areas was used to identify potential antioxidants. This is a novel approach to simultaneously evaluate the antioxidant power of a component versus a free radical, and to identify it in a vegetal matrix. The structures of the antioxidants in the samples were identified using tandem mass spectrometry and comparison with standards. Fourteen compounds were found to possess potential antioxidant activity, and their free radical scavenging capacities were investigated. The order of scavenging capacity of 14 compounds was compared according to their free radical scavenging rate. 4',5,6,7-Tetrahydroxyflavone (radical scavenging rate: 0.05253 mL mg(-1) s(-1) ) showed the strongest capability for scavenging free radicals. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Quantification of Photocyanine in Human Serum by High-Performance Liquid Chromatography-Tandem Mass Spectrometry and Its Application in a Pharmacokinetic Study

    Directory of Open Access Journals (Sweden)

    Bing-Tian Bi

    2014-01-01

    Full Text Available Photocyanine is a novel anticancer drug. Its pharmacokinetic study in cancer patients is therefore very important for choosing doses, and dosing intervals in clinical application. A rapid, selective and sensitive high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS method was developed and validated for the determination of photocyanine in patient serum. Sample preparation involved one-step protein precipitation by adding methanol and N,N-dimethyl formamide to 0.1 mL serum. The detection was performed on a triple quadrupole tandem mass spectrometer operating in multiple reaction-monitoring (MRM mode. Each sample was chromatographed within 7 min. Linear calibration curves were obtained for photocyanine at a concentration range of 20–2000 ng/mL (r>0.995, with the lower limit of quantification (LLOQ being 20 ng/mL. The intrabatch accuracy ranged from 101.98% to 107.54%, and the interbatch accuracy varied from 100.52% to 105.62%. Stability tests showed that photocyanine was stable throughout the analytical procedure. This study is the first to utilize the HPLC-MS/MS method for the pharmacokinetic study of photocyanine in six cancer patients who had received a single dose of photocyanine (0.1 mg/kg administered intravenously.

  17. Urinary free cortisol assessment by liquid chromatography tandem mass spectrometry: a case study of ion suppression due to unacquainted administration of piperacillin

    Science.gov (United States)

    Danese, Elisa; Salvagno, Gian Luca; Guzzo, Alessandra; Scurati, Samuele; Fava, Cristiano; Lippi, Giuseppe

    2017-01-01

    Introduction Liquid chromatography coupled to atmospheric pressure ionization tandem mass spectrometry (LC-ESI-MS/MS) is currently considered the reference method for quantitative determination of urinary free cortisol (UFC). One of the major drawbacks of this measurement is a particular form of matrix effect, conventionally known as ion suppression. Materials and methods We describe here the case of a 66-year-old-patient referred to the daily service of general medicine for intravenous antibiotic administration due to a generalized Staphylococcus aureus infection and for routine 24 hours UFC monitoring in the setting of glucocorticoid replacement therapy. Results The observation of 10-fold decrease of internal standard of cortisol signal led us to hypothesize the presence of an ion suppression effect due to a co-eluting endogenous compound. Screening analysis of tandem mass spectrometry (MS/MS) spectra of the interfering molecule, along with in vitro confirmation analyses, were suggestive of the presence of high concentration of piperacillin. The problem was then easily solved with minor modifications of the chromatographic technique. Conclusions According to our findings, antibiotic therapy with piperacillin/tazobactam should be regarded as an important interference in UFC assessment, which may potentially affect detection capability, precision and accuracy of this measurement. This case report emphasizes that accurate anamnesis and standardization of all phases of urine collection are essential aspects for preventing potential interference in laboratory testing. PMID:29180920

  18. High-Resolution Liquid Chromatography Tandem Mass Spectrometry Enables Large Scale Molecular Characterization of Dissolved Organic Matter

    Directory of Open Access Journals (Sweden)

    Daniel Petras

    2017-12-01

    Full Text Available Dissolved organic matter (DOM is arguably one of the most complex exometabolomes on earth, and is comprised of thousands of compounds, that together contribute more than 600 × 1015 g carbon. This reservoir is primarily the product of interactions between the upper ocean's microbial food web, yet abiotic processes that occur over millennia have also modified many of its molecules. The compounds within this reservoir play important roles in determining the rate and extent of element exchange between inorganic reservoirs and the marine biosphere, while also mediating microbe-microbe interactions. As such, there has been a widespread effort to characterize DOM using high-resolution analytical methods including nuclear magnetic resonance spectroscopy (NMR and mass spectrometry (MS. To date, molecular information in DOM has been primarily obtained through calculated molecular formulas from exact mass. This approach has the advantage of being non-targeted, accessing the inherent complexity of DOM. Molecular structures are however still elusive and the most commonly used instruments are costly. More recently, tandem mass spectrometry has been employed to more precisely identify DOM components through comparison to library mass spectra. Here we describe a data acquisition and analysis workflow that expands the repertoire of high-resolution analytical approaches available to access the complexity of DOM molecules that are amenable to electrospray ionization (ESI MS. We couple liquid chromatographic separation with tandem MS (LC-MS/MS and a data analysis pipeline, that integrates peak extraction from extracted ion chromatograms (XIC, molecular formula calculation and molecular networking. This provides more precise structural characterization. Although only around 1% of detectable DOM compounds can be annotated through publicly available spectral libraries, community-wide participation in populating and annotating DOM datasets could rapidly increase the

  19. Determination of genkwanin in rat plasma by liquid chromatography-tandem mass spectrometry: application to a bioavailability study.

    Science.gov (United States)

    Song, Yanqing; Zhang, Sixi; Liu, Hong; Jin, Xiangqun

    2013-10-01

    We developed and validated a sensitive, rapid, and specific liquid chromatography tandem mass spectrometry method to determine genkwanin in rat plasma. Genistein was used as the internal standard. After liquid-liquid extraction with ethyl acetate, the chromatographic separation of genkwanin was achieved by using a reversed-phase HPLC using Agela Venusil MP-C18 analytical column (2.1 mm × 50 mm, 5 μm particles) with a mobile phase of methanol (A)-water (B) (65:35, v/v) containing 5mM ammonium acetate and 0.1% formic acid. The detection was performed by negative ion electrospray ionization in multiple-reaction monitoring mode by using transitions of m/z 283.1→268.1 and m/z 269.1→133.0 for genkwanin and IS, respectively. Good linearity was observed in the concentration range of 3.84 ng/ml to 3,840 ng/ml (r(2)>0.99), and the lower limit of quantification was 3.84 ng/ml in 100 μl of rat plasma. The intra- and inter-day accuracy and precision of genkwanin were both within acceptable limits. This present method was successfully applied to a pharmacokinetic study of genkwanin in rats following oral (50mg/kg) and intravenous (5mg/kg) administration. For the oral administration group, the maximum mean concentration of genkwanin in plasma (Cmax, 36.9 ± 9.4 ng/ml) was achieved at 3.83 ± 1.33 h (Tmax), and the area under the plasma concentration versus time curve from 0 h to 12h (AUC0-12h) was 218 ± 40 ngh/ml. For the intravenous administration group, essential pharmacokinetic parameters such as Cmax (1,755 ± 197 ng/ml) and AUC0-12h (2,349 ± 573 ngh/ml) were shown. The result showed that the compound was poorly absorbed with an absolute bioavailability of approximately 1.1%. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.

  20. Optimization of a Differential Ion Mobility Spectrometry-Tandem Mass Spectrometry Method for High-Throughput Analysis of Nicotine and Related Compounds: Application to Electronic Cigarette Refill Liquids.

    Science.gov (United States)

    Regueiro, Jorge; Giri, Anupam; Wenzl, Thomas

    2016-06-21

    Fast market penetration of electronic cigarettes is leading to an exponentially growing number of electronic refill liquids with different nicotine contents and an endless list of flavors. Therefore, rapid and simple methods allowing a fast screening of these products are necessary to detect harmful substances which can negatively impact the health of consumers. In this regard, the present work explores the capabilities of differential ion mobility spectrometry coupled to tandem mass spectrometry for high-throughput analysis of nicotine and 11 related compounds in commercial refill liquids for electronic cigarettes. The influence of main factors affecting the ion mobility separation, such as modifier types and concentration, separation voltage, and temperature, was systematically investigated. Despite small molecular weight differences among the studied compounds, a good separation was achieved in the ion mobility cell under the optimized conditions, which involved the use of ethanol as a polar gas-phase chemical modifier. Indeed, differential ion mobility was able to resolve (resolution >4) nicotine from its structural isomer anabasine without the use of any chromatographic separation. The quantitative performance of the proposed method was then evaluated, showing satisfactory precision (RSD ≤ 16%) and recoveries ranging from 85 to 100% for nicotine, and from 84 to 126% for the rest of the target analytes. Several commercial electronic cigarette refill liquids were analyzed to demonstrate the applicability of the method. In some cases, significant differences were found between labeled and measured levels of nicotine. Anatabine, cotinine, myosmine, and nornicotine were also found in some of the analyzed samples.

  1. Comprehensive determination of flavouring additives and nicotine in e-cigarette refill solutions. Part I: Liquid chromatography-tandem mass spectrometry analysis.

    Science.gov (United States)

    Aszyk, Justyna; Kubica, Paweł; Kot-Wasik, Agata; Namieśnik, Jacek; Wasik, Andrzej

    2017-10-13

    Liquid chromatography-tandem mass spectrometry with electrospray ionization (HPLC-ESI-MS/MS) methods were developed for the simultaneous determination of 42 flavouring compounds and nicotine in liquids for e-cigarettes. The chromatographic separation was performed using an Ace ® Ultracore™ SuperC18™ (100×2.1mm, 2.5μm) column in both acidic and alkaline pH conditions to separate all the compounds. A simple "dilute & shoot" approach was used for the sample preparation. The method validation was performed by evaluating key analytical parameters such as linearity, accuracy, selectivity, precision, limit of detection (LOD) and limit of quantification (LOQ). The calibration curves showed good linearity within the specific ranges for the investigated compounds with correlation coefficients greater than 0.990 in each case. The recovery for all the investigated compounds varied from 89% to 110%. The intra- and inter-day precision were within the acceptable limits (±15%) at all tested concentrations. The applicability of the methods was examined by analysing 25 liquid samples from e-cigarettes commercially available on the Polish market. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Direct coupling of a liquid chromatograph to a continuous flow hydrogen nuclear magnetic resonance detector for analysis of petroleum and synthetic fuels

    International Nuclear Information System (INIS)

    Haw, J.F.; Glass, T.E.; Hausler, D.W.; Motell, E.; Dorn, H.C.

    1980-01-01

    Initial results obtained for a flow 1 H nuclear magnetic resonance (NMR) detector directly coupled to a liquid chromatography unit are described. Results achieved for a model mixture and several jet fuel samples are discussed. Chromatographic separation of alkanes, alkylbenzenes, and substituted naphthalenes present in the jet fuel samples are easily identified with the 1 H NMR detector. Results with our present flow 1 H NMR insert indicate that 5-Hz linewidths are readily obtainable for typical chromatographic flow rates. The limitations and advantages of this liquid chromatography detector are compared with more commonly employed detectors (e.g., refractive index detectors). 11 figures

  3. Determination of trihalomethanes in waters by ionic liquid-based single drop microextraction/gas chromatographic/mass spectrometry.

    Science.gov (United States)

    Aguilera-Herrador, Eva; Lucena, Rafael; Cárdenas, Soledad; Valcárcel, Miguel

    2008-10-31

    A simple, rapid, solventless method for the determination of trihalomethanes (THMs) (chloroform, bromodichloromethane, dibromochloromethane and bromoform) in water samples is presented. The analytes are extracted from the headspace of the aqueous matrix into a 2 microL drop of the ionic liquid 1-octyl-3-methyl-imidazolium hexafluorophosphate working at 30 degrees C for 30 min. The separation and detection of the target compounds is accomplished by gas chromatography/mass spectrometry owing to the use of an interface that efficiently transfers the analytes extracted in the ionic liquid drop to the gas chromatograph while preventing the ionic liquid from entering the column. The detection limits obtained are below the values compelled by the legislation, ranging from 0.5 microg L(-1) for chloroform and bromodichloromethane to 0.9 microg L(-1) for dibromochloromethane. The use of ionic liquid in the extraction procedure avoids the use of organic solvents and leads to relative standard deviations that range from 3.1% to 4.8%.

  4. Liquid chromatographic method for simultaneous determination of citalopram with NSAIDs in bulk drug, pharmaceutical formulation and human serum

    International Nuclear Information System (INIS)

    Ali, S.N.; Akram, S.

    2017-01-01

    A high performance liquid chromatographic method was developed and validated to simultaneously quantify citalopram with piroxicam, celecoxib and diclofenac sodium. Chromatographic analysis was performed at ambient temperature using Shimadzu Shim-pack CLC-ODS (M) 25M column linked to a UV-visible detector adjusted at 230 nm, employing 80:20 (v/v) methanol: water (pH 3.5) as mobile phase with flow rate 1.0 mL min-1. Validation was performed in the ranges 0.6-20, 0.9-28, 0.6-20 and 1.0-32 mu g mL-1 with lowest level corresponding to detection limit 16.45, 23.33, 27.66 and 14.44 ng mL-1 respectively. With-in the day precision ranged from 0.14-1.67% and between-day precision from 0.40-1.50%, accuracies were 99.61-100.86%. The analytes were successfully detected without any observable interference in pharmaceutical formulation and human serum samples demonstrating effectiveness of method. (author)

  5. Liquid Chromatographic-Chemometric Techniques for the Simultaneous HPLC Determination of Lansoprazole, Amoxicillin and Clarithromycin in Commercial Preparation.

    Science.gov (United States)

    Aktas, A Hakan; Saridag, Ayse Mine

    2017-09-01

    Two multivariate calibration-prediction techniques, principal component regression (PCR) and partial least-squares regression (PLSR) were applied to the chromatographic multicomponent analysis of the drug containing lansoprazole (LAN), clarithromycin (CLA) and amoxicillin (AMO). Optimum chromatographic separation of LAN, CLA and AMO with atorvastatin as the internal standard (IS) was obtained by using Xterra® RP18 column 5 μm 4.6 × 250 mm2, and 25 mM ammonium chloride buffer prepared ammonium chloride, acetonitrile and bidistilled water (45:45:10 v/v) as the mobile phase at flow rate 1.0 mL/min. The high pressure liquid chromatography data sets consisting of the ratios of analyte peak areas to the IS peak area were obtained by using diode array detector detection at five wavelengths (205, 210, 215, 220 and 225 nm). LC-chemometric calibration for LAN, CLA and AMO were separately constructed by using the relationship between the peak-area ratio and training sets for each analyte. A series of synthetic solutions containing different concentrations of LAN, CLA and AMO were used to check the prediction ability of the PCR and PLS. Both of the two-chemometric methods in this study can be satisfactorily used for the quantitative analysis and for dissolutions tests of multicomponent commercial drug. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  6. An innovative, simple, fast, and less toxic high-performance liquid chromatographic method for determination of prednisone in capsules

    Directory of Open Access Journals (Sweden)

    Pedro Henrique Reis da Silva

    2017-06-01

    Full Text Available ABSTRACT Prednisone is an anti-inflammatory steroid drug widely used in clinical practice. However, no high-performance liquid chromatographic (HPLC method has been described in the literature for the determination of prednisone in capsules until now. Thus, an HPLC method was developed using a C18 (250x4.0, 5 µm column, with methanol:water (70:30 as mobile phase at a flow rate of 1 mL/min and detection at 240 nm. The developed method was validated following current Brazilian legislation. Additionally, linearity was assessed by evaluating the assumptions of normality, homoscedasticity, and independency of residuals, and the fit to the linear model. The method showed linearity (r2>0.99 over the range of 14.0-26.0 µg/mL, selectivity, precision (RSD<2.0%, robustness, and accuracy (average recovery of 100.05%. The chromatographic procedure was applied for assay and uniformity content determination of three different batches of prednisone capsules, showing to be suitable for their quality control.

  7. A high performance liquid chromatographic assay of Mefloquine in saliva after a single oral dose in healthy adult Africans

    Directory of Open Access Journals (Sweden)

    Gbotosho Grace O

    2012-02-01

    Full Text Available Abstract Background Mefloquine-artesunate is a formulation of artemisinin based combination therapy (ACT recommended by the World Health Organization and historically the first ACT used clinically. The use of ACT demands constant monitoring of therapeutic efficacies and drug levels, in order to ensure that optimum drug exposure is achieved and detect reduced susceptibility to these drugs. Quantification of anti-malarial drugs in biological fluids other than blood would provide a more readily applicable method of therapeutic drug monitoring in developing endemic countries. Efforts in this study were devoted to the development of a simple, field applicable, non-invasive method for assay of mefloquine in saliva. Methods A high performance liquid chromatographic method with UV detection at 220 nm for assaying mefloquine in saliva was developed and validated by comparing mefloquine concentrations in saliva and plasma samples from four healthy volunteers who received single oral dose of mefloquine. Verapamil was used as internal standard. Chromatographic separation was achieved using a Hypersil ODS column. Results Extraction recoveries of mefloquine in plasma or saliva were 76-86% or 83-93% respectively. Limit of quantification of mefloquine was 20 ng/ml. Agreement between salivary and plasma mefloquine concentrations was satisfactory (r = 0.88, p Conclusion Disposition of mefloquine in saliva paralleled that in plasma, making salivary quantification of mefloquine potentially useful in therapeutic drug monitoring.

  8. A simple subcritical chromatographic test for an extended ODS high performance liquid chromatography column classification.

    Science.gov (United States)

    Lesellier, Eric; Tchapla, Alain

    2005-12-23

    This paper describes a new test designed in subcritical fluid chromatography (SFC) to compare the commercial C18 stationary phase properties. This test provides, from a single analysis of carotenoid pigments, the absolute hydrophobicity, the silanol activity and the steric separation factor of the ODS stationary phases. Both the choice of the analytical conditions and the validation of the information obtained from the chromatographic measurements are detailed. Correlations of the carotenoid test results with results obtained from other tests (Tanaka, Engelhard, Sander and Wise) performed both in SFC and HPLC are discussed. Two separation factors, calculated from the retention of carotenoid pigments used as probe, allowed to draw a first classification diagram. Columns, which present identical chromatographic behaviors are located in the same area on this diagram. This location can be related to the stationary phase properties: endcapping treatments, bonding density, linkage functionality, specific area or silica pore diameter. From the first classification, eight groups of columns are distinguished. One group of polymer coated silica, three groups of polymeric octadecyl phases, depending on the pore size and the endcapping treatment, and four groups of monomeric stationary phases. An additional classification of the four monomeric groups allows the comparison of these stationary phases inside each group by using the total hydrophobicity. One hundred and twenty-nine columns were analysed by this simple and rapid test, which allows a comparison of columns with the aim of helping along their choice in HPLC.

  9. Simultaneous derivatisation and preconcentration of parabens in food and other matrices by isobutyl chloroformate and dispersive liquid-liquid microextraction followed by gas chromatographic analysis.

    Science.gov (United States)

    Jain, Rajeev; Mudiam, Mohana Krishna Reddy; Chauhan, Abhishek; Ch, Ratnasekhar; Murthy, R C; Khan, Haider A

    2013-11-01

    A simple, rapid and economical method has been proposed for the quantitative determination of parabens (methyl, ethyl, propyl and butyl paraben) in different samples (food, cosmetics and water) based on isobutyl chloroformate (IBCF) derivatisation and preconcentration using dispersive liquid-liquid microextraction in single step. Under optimum conditions, solid samples were extracted with ethanol (disperser solvent) and 200 μL of this extract along with 50 μL of chloroform (extraction solvent) and 10 μL of IBCF was rapidly injected into 2 mL of ultra-pure water containing 150 μL of pyridine to induce formation of a cloudy state. After centrifugation, 1 μL of the sedimented phase was analysed using gas chromatograph-flame ionisation detector (GC-FID) and the peaks were confirmed using gas chromatograph-positive chemical ionisation-mass spectrometer (GC-PCI-MS). Method was found to be linear over the range of 0.1-10 μg mL(-1) with square of correlation coefficient (R(2)) in the range of 0.9913-0.9992. Limit of detection (LOD) and limit of quantification (LOQ) were found to be 0.029-0.102 μg mL(-1) and 0.095-0.336 μg mL(-1) with a signal to noise ratio of 3:1 and 10:1, respectively. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. Quantification of steroid hormones in human serum by liquid chromatography-high resolution tandem mass spectrometry.

    Science.gov (United States)

    Matysik, Silke; Liebisch, Gerhard

    2017-12-01

    A limited specificity is inherent to immunoassays for steroid hormone analysis. To improve selectivity mass spectrometric analysis of steroid hormones by liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been introduced in the clinical laboratory over the past years usually with low mass resolution triple-quadrupole instruments or more recently by high resolution mass spectrometry (HR-MS). Here we introduce liquid chromatography-high resolution tandem mass spectrometry (LC-MS/HR-MS) to further increase selectivity of steroid hormone quantification. Application of HR-MS demonstrates an enhanced selectivity compared to low mass resolution. Separation of isobaric interferences reduces background noise and avoids overestimation. Samples were prepared by automated liquid-liquid extraction with MTBE. The LC-MS/HR-MS method using a quadrupole-Orbitrap analyzer includes eight steroid hormones i.e. androstenedione, corticosterone, cortisol, cortisone, 11-deoxycortisol, 17-hydroxyprogesterone, progesterone, and testosterone. It has a run-time of 5.3min and was validated according to the U.S. Food and Drug Administration (FDA) and the European Medicines Agency (EMA) guidelines. For most of the analytes coefficient of variation were 10% or lower and LOQs were determined significantly below 1ng/ml. Full product ion spectra including accurate masses substantiate compound identification by matching their masses and ratios with authentic standards. In summary, quantification of steroid hormones by LC-MS/HR-MS is applicable for clinical diagnostics and holds also promise for highly selective quantification of other small molecules. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Simultaneous drug identification in urine of sexual assault victims by using liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Lee, Hei Hwa; Chen, Suen Chi; Lee, Jong Feng; Lin, Hsin Yu; Chen, Bai Hsiun

    2018-01-01

    According to domestic and international epidemiological investigation, the proportion of substance involved sexual assault has the trend of ascent. In the past, laboratory methods that investigated urine sample of the sexual assault victims was to screen with enzyme immunoassay and then confirmed with mass spectrometry. The objective of the study is to simultaneously identify abused drugs in 126 decoded urine samples of sexual assault victims by liquid chromatography tandem mass spectrometry. The instrument was operated in multiple-reaction monitoring with an electro-spray positive ionization mode. Chromatograms were separated with ACE5 C18 column on a gradient of acetonitrile. After liquid-liquid extraction, samples were passed through a 0.22μm PVDF filter before injection into the system. The limits of quantitation ranged from 0.2 to 10ng/mL. The precision (CV) results were below 12.9% (intraday) and 15.0% (interday). The intraday accuracy ranged from 84.8 to 121.0%, interday accuracy ranged from 72.0 to 117.3%. We found that 29 (23.0%) were positive for drugs. The most common drug identified is flunitrazepam (11.1%), followed by nimetazepam and ketamine (7.9%), some new psychoactive substances, such as 2C-B, mephedrone, methylone, PMA and PMMA were also identified. We identified abused drugs, benzodiazepines, and new psychoactive substances in urine of sexual assault victims by using liquid chromatography tandem mass spectrometry. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Development of liquid chromatographic methods for the determination of phytosterols in Standard Reference Materials containing saw palmetto.

    Science.gov (United States)

    Bedner, Mary; Schantz, Michele M; Sander, Lane C; Sharpless, Katherine E

    2008-05-23

    Liquid chromatographic (LC) methods using atmospheric pressure chemical ionization/mass spectrometric (APCI-MS) detection were developed for the separation and analysis of the phytosterols campesterol, cycloartenol, lupenone, lupeol, beta-sitosterol, and stigmasterol. Brassicasterol and cholesterol were also included for investigation as internal standards. The methods were used to identify and quantify the phytosterols in each of two Serenoa repens (saw palmetto) Standard Reference Materials (SRMs) developed by the National Institute of Standards and Technology (NIST). Values obtained by LC-MS were compared to those obtained using the more traditional approach of gas chromatography with flame ionization detection. This is the first reported use of LC-MS to determine phytosterols in saw palmetto dietary supplement materials.

  13. Development and validation of high-perfomance liquid chromatographic method for determination of ofloxacin and lomefloxacin in human plasma

    Directory of Open Access Journals (Sweden)

    DRAGICA ZENDELOVSKA

    2005-12-01

    Full Text Available Ahigh-performance liquid chromatographicmethod for the determination of ofloxacin and lomefloxacin in human plasma has been developed and validated. The effect of organic modifiers on the retention of the investigated drugs was investigated. Asimple isocratic chromatographic assay with UV-detection at 280 nm was performed on a Hibar Lichrospher 100 RP 8 column (250×4.6 mm, 5 mm. Merck, Germany using a mixture of acetonitrile and 0.5 % triethylamine in water (pH adjusted to 2.5 with H3PO4 (15:85, V/V as the mobile phase at flow rate of 1.2 mL min-1. The calibration curves were linear in the concentration ragne of 0.5 – 6.0 mg mL-1 for ofloxacin and 0.2-4.5 mg mL-1 for lomefloxacin.

  14. General and selective isolation procedure for high-performance liquid chromatographic determination of anabolic steroids in tissues.

    Science.gov (United States)

    Laganà, A; Marino, A

    1991-12-27

    A multi-residue method has been developed for the determination of anabolic steroids in animal tissue. The analytes are extracted from tissue with methanol and the extract is subjected to two solid-phase extractions, one using a non-specific adsorbing material, such as graphitized carbon black (Carbopack B), and the other Amberlite CG-400 I in the OH form. This procedure allowed the neutral anabolics (testosterone, trenbolone and progesterone) to be isolated and separated from the acidic type (phenolic group), such as diethylstilbestrol, oestradiol, zeranol/zearalenone and their respective metabolites. The determination was effected using high-performance liquid chromatography with different detectors (ultraviolet, fluorimetric and electrochemical). Several analytical parameters were studied: chromatographic conditions, recoveries, evaporation step, solvent flow-rate, cartridges reusability, interference of plastic cartridges. For all the anabolics investigated the recoveries were greater than 83.6%.

  15. High performance liquid chromatographic determination of vanadium in crude oils and cobalt and iron in pharmaceutical preparations

    International Nuclear Information System (INIS)

    Khuhawar, M.Y.; Lanjwani, S.N.; Khaskhely, G.Q.

    1993-01-01

    High performance liquid Chromatographic (HPLC) method has ben developed for the determination of vanadium in crude oils, based on acid decomposition of oils, followed by complexation with bis (salicylaldehyde) tetramethyl ethylenediamine (H2SA2Ten). The complex is extracted in organic phase and is separated from copper and nickel using normal phase HPLC column. Detection is achieved using spectrophtmetric detector. The vanadium in oil is obtained at sub microgram/g level. Similarly cobalt(II), cobalt(III) and iron(II) are separated on reversed phase HPLC column. Pre column derivatization is used to develop HPLC method for the determination of cobalt and iron in pharmaceutical preparations. Finally results are compared using atomic absorption spectrometer. (author)

  16. High performance liquid chromatographic hydrocarbon group-type analyses of mid-distillates employing fuel-derived fractions as standards

    Science.gov (United States)

    Seng, G. T.; Otterson, D. A.

    1983-01-01

    Two high performance liquid chromatographic (HPLC) methods have been developed for the determination of saturates, olefins and aromatics in petroleum and shale derived mid-distillate fuels. In one method the fuel to be analyzed is reacted with sulfuric acid, to remove a substantial portion of the aromatics, which provides a reacted fuel fraction for use in group type quantitation. The second involves the removal of a substantial portion of the saturates fraction from the HPLC system to permit the determination of olefin concentrations as low as 0.3 volume percent, and to improve the accuracy and precision of olefins determinations. Each method was evaluated using model compound mixtures and real fuel samples.

  17. A novel two-dimensional liquid chromatographic system for the online toxicity prediction of pharmaceuticals and related substances

    Energy Technology Data Exchange (ETDEWEB)

    Li, Jian; Xu, Li [Tongji School of Pharmacy, Huazhong University of Science and Technology, Wuhan 430030 (China); Shi, Zhi-guo, E-mail: shizg@whu.edu.cn [Department of Chemistry, Wuhan University, Wuhan 430072 (China); Hu, Min [Hubei Instrument for Food and Drug Control, Wuhan (China)

    2015-08-15

    Highlights: • A novel two-dimensional liquid chromatographic system was developed. • The 1st dimension was ODS to separate components in the sample. • The 2nd dimension was biopartitioning micellar chromatography to predict toxicity. • The system was used to screen toxicity of pharmaceuticals and related substances. • It was promising for fast online toxicity screening of complex sample in one step. - Abstract: In this study, a novel two-dimensional liquid chromatographic (2D-LC) system was developed for simultaneous separation and toxicity prediction of pharmaceutical and its related substances. A conventional ODS column was used on the 1st-D to separate the sample; while, bio-partitioning micellar chromatography served as the 2nd-D to predict toxicity of the components. The established system was tested for the toxicity of ibuprofen and its impurities with known toxicity. With only one injection, ibuprofen and its impurities were separated on the 1st-D; and LC50 values of individual impurity were obtained based on the quantitative retention–activity relationships, which agreed well with the reported data. Furthermore, LC50 values of photolysis transformation products (TPs) of carprofen, ketoprofen and diclofenac acid (as unknown compounds) were screened in this 2D-LC system, which could be an indicator of the toxicity of these TPs and was meaningful for the environmental monitoring and drinking water treatment. The established 2D-LC system was cost-effective, time-saving and reliable, and was promising for fast online screening of toxicity of known and unknown analytes in the complex sample in a single step. It may find applications in environment, pharmaceutical and food, etc.

  18. A novel two-dimensional liquid chromatographic system for the online toxicity prediction of pharmaceuticals and related substances

    International Nuclear Information System (INIS)

    Li, Jian; Xu, Li; Shi, Zhi-guo; Hu, Min

    2015-01-01

    Highlights: • A novel two-dimensional liquid chromatographic system was developed. • The 1st dimension was ODS to separate components in the sample. • The 2nd dimension was biopartitioning micellar chromatography to predict toxicity. • The system was used to screen toxicity of pharmaceuticals and related substances. • It was promising for fast online toxicity screening of complex sample in one step. - Abstract: In this study, a novel two-dimensional liquid chromatographic (2D-LC) system was developed for simultaneous separation and toxicity prediction of pharmaceutical and its related substances. A conventional ODS column was used on the 1st-D to separate the sample; while, bio-partitioning micellar chromatography served as the 2nd-D to predict toxicity of the components. The established system was tested for the toxicity of ibuprofen and its impurities with known toxicity. With only one injection, ibuprofen and its impurities were separated on the 1st-D; and LC50 values of individual impurity were obtained based on the quantitative retention–activity relationships, which agreed well with the reported data. Furthermore, LC50 values of photolysis transformation products (TPs) of carprofen, ketoprofen and diclofenac acid (as unknown compounds) were screened in this 2D-LC system, which could be an indicator of the toxicity of these TPs and was meaningful for the environmental monitoring and drinking water treatment. The established 2D-LC system was cost-effective, time-saving and reliable, and was promising for fast online screening of toxicity of known and unknown analytes in the complex sample in a single step. It may find applications in environment, pharmaceutical and food, etc

  19. Multiclass method for the determination of pharmaceuticals and personal care products in compost from sewage sludge using ultrasound and salt-assisted liquid-liquid extraction followed by ultrahigh performance liquid chromatography-tandem mass spectrometry analysis.

    Science.gov (United States)

    Luque-Muñoz, A; Vílchez, J L; Zafra-Gómez, A

    2017-07-21

    An analytical method for the analysis of 16 pharmaceuticals and personal care products in compost from sewage sludge is successfully validated. Ultrasound assisted extraction with a mixture of acetonitrile:ethyl acetate (1:1, v/v) containing 10% (v/v) of acetic acid was carried out. Two cycles of extraction of 10min were applied. A clean-up of the extracts using salt-assisted liquid-liquid extraction (SALLE) was also included. Experimental design was used for the optimization of the main parameters involved in the extraction and cleaned-up steps. The chromatographic separation was carried out by ultrahigh performance liquid chromatography using a mobile phase gradient mixture of a 13mM buffer ammonium formate solution (pH 9.25) (solvent A) and methanol (solvent B). An ACQUITY UPLC ® BEH C18 column (1.7μm; 2.1×50mm) column was used. Analytes were separated in less than 11min. The compounds were detected and quantified using single reaction monitoring electrospray tandem mass spectrometry. The limits of detection calculated ranged from 0.5 to 4ngg -1 d.w., and the limits of quantification from 2 to 13ngg -1 d.w. Recoveries from 93% to 111%, with relative standar deviations lower than 11% in all cases, were obtained. The method was applied to natural compost samples. High concentrations of some analytes were found. Ketoprofen (510ngg -1 d.w.), methylparaben (240ngg -1 d.w.), diclofenac (175ngg -1 d.w.) and flufenamic acid (128ngg -1 d.w.) were the most abundant. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Optimization of the reversed-phase high-performance liquid chromatographic separation of synthetic estrogenic and progestogenic steroids using the multi-criteria decision making method

    NARCIS (Netherlands)

    Smilde, A. K.; Bruins, C. H.; Doornbos, D. A.; Vink, J.

    1987-01-01

    The optimization of the reversed-phase high-performance liquid chromatographic separation of a mixture of ethynylestradiol, desogestrel and three related compounds is described. A procedure is used that allows the prediction of the capacity factors of each individual synthetic steroid, depending on

  1. INTERLABORATORY STUDY OF A THERMOSPRAY-LIQUID CHROMATOGRAPHIC/MASS SPECTROMETRIC METHOD FOR SELECTED N-METHYL CARBAMATES, N-METHYL CARBAMOYLOXIMES, AND SUBSTITUTED UREA PESTICIDES

    Science.gov (United States)

    A thermospray-liquid chromatographic/mass spectrometric (TS-LC/MS) method was evaluated in an interlaboratory study for determining 3 N-methyl carbamates (bendiocarb, carbaryl, and carbofuran), 3-N-methyl carbamoyloximes (aldicarb, methomyl, and oxamyl), 2 substituted urea pestic...

  2. HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC PROFILING OF TRYPTOPHAN AND RELATED INDOLES IN BODY-FLUIDS AND TISSUES OF CARCINOID PATIENTS

    NARCIS (Netherlands)

    KEMA, IP; SCHELLINGS, AMJ; HOPPENBROUWERS, CJM; RUTGERS, HM; DEVRIES, EGE; MUSKIET, FAJ

    1993-01-01

    A high performance liquid chromatographic method with quaternary gradient elution and fluorometric detection was developed for profiling of tryptophan (TRP), 5-hydroxytryptophan, serotonin (5-HT) and 5-hydroxyindole-3-acetic acid (5-HIAA) in urine, platelet-rich plasma and (tumour) tissue of

  3. Use of on-line supercritical fluid extraction-supercritical fluid chromatography/tandem mass spectrometry to analyze disease biomarkers in dried serum spots compared with serum analysis using liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Suzuki, Makoto; Nishiumi, Shin; Kobayashi, Takashi; Sakai, Arata; Iwata, Yosuke; Uchikata, Takato; Izumi, Yoshihiro; Azuma, Takeshi; Bamba, Takeshi; Yoshida, Masaru

    2017-05-30

    The analytical stability and throughput of biomarker assays based on dried serum spots (DSS) are strongly dependent on the extraction process and determination method. In the present study, an on-line system based on supercritical fluid extraction-supercritical fluid chromatography coupled with tandem mass spectrometry (SFE-SFC/MS/MS) was established for analyzing the levels of disease biomarkers in DSS. The chromatographic conditions were investigated using the ODS-EP, diol, and SIL-100A columns. Then, we optimized the SFE-SFC/MS/MS method using the diol column, focusing on candidate biomarkers of oral, colorectal, and pancreatic cancer that were identified using liquid chromatography (LC)/MS/MS. By using this system, four hydrophilic metabolites and 17 hydrophobic metabolites were simultaneously detected within 15 min. In an experiment involving clinical samples, PC 16:0-18:2/16:1-18:1 exhibited 93.8% sensitivity and 64.3% specificity, whereas PC 17:1-18:1/17:0-18:2 showed 81.3% sensitivity and 92.9% specificity for detecting oral cancer. In addition, assessments of the creatine levels demonstrated 92.3% sensitivity and 78.6% specificity for detecting colorectal cancer. The results of this study indicate that our method has great potential for clinical diagnosis and would be suitable for large-scale screening. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  4. A column switching ultrahigh-performance liquid chromatography-tandem mass spectrometry method to determine anandamide and 2-arachidonoylglycerol in plasma samples.

    Science.gov (United States)

    Marchioni, Camila; de Souza, Israel Donizeti; Grecco, Caroline Fernandes; Crippa, José Alexandre; Tumas, Vitor; Queiroz, Maria Eugênia Costa

    2017-05-01

    This study reports a fast, sensitive, and selective column switching ultrahigh-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method to determine the endocannabinoids (eCBs), anandamide (AEA), and 2-arachidonoylglycerol (2-AG) in plasma samples. This bidimensional system used a restricted access media column (RP-8 ADS, 25 mm × 4 mm × 25 μM) in the first dimension and a core-shell Kinetex C18 (100 mm × 2, 1.7 mm × 1 μM) column in the second dimension, followed by detection in a mass spectrometer triple quadrupole (multiple reactions monitoring mode) operating in the positive mode. RP-8 ADS was used for trace enrichment of eCBs (reverse phase partitioning) and macromolecular matrix size exclusion; the core-shell column was used for the chromatographic separation. The column switching UHPLC-MS/MS method presented a linear range spanning from 0.1 ng mL -1 (LOQ) to 6 ng mL -1 for AEA and from 0.04 ng mL -1 (LOQ) to 10 ng mL -1 for 2-AG. Excluding the LLOQ values, the precision assays provided coefficients of variation lower than 8% and accuracy with relative standard error values lower than 14%. Neither carryover nor matrix effects were detected. This high-throughput column switching method compared to conventional methods is time saving as it involves fewer steps, consumes less solvent, and presents lower LLOQ. The column switching UHPLC-MS/MS method was successfully applied to determine AEA and 2-AG in plasma samples obtained from Alzheimer's disease patients. Graphical abstract A column switching ultra high-performance liquid chromatography-tandem mass spectrometry method using RP-8 ADS column and core shell column to determine endocannabinoids in plasma samples.

  5. Determination of phosphatidylethanolamine molecular species in various food matrices by liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS2).

    Science.gov (United States)

    Zhou, Li; Zhao, Minjie; Ennahar, Saïd; Bindler, Françoise; Marchioni, Eric

    2012-04-01

    A liquid chromatographic-electrospray ionization-tandem mass spectrometric (LC-ESI-MS(2)) method has been developed for determination of the molecular species of phosphatidylethanolamine (PE) in four food matrices (soy, egg yolk, ox liver, and krill oil). The extraction and purification method consisted of a pressurized liquid extraction procedure for total lipid (TL) extraction, purification of phospholipids (PLs) by adsorption on a silica gel column, and separation of PL classes by semi-preparative normal-phase HPLC. Separation and identification of PE molecular species were performed by reversed-phase HPLC coupled with electrospray ionization tandem mass spectrometry (ESI-MS(2)). Methanol containing 5 mmol L(-1) ammonium formate was used as the mobile phase. A variety of PE molecular species were detected in the four food matrices. (C16:0-C18:2)PE, (C18:2-C18:2)PE, and (C16:0-C18:1)PE were the major PE molecular species in soy. Egg yolk PE contained (C16:0-C18:1)PE, (C18:0-C18:1)PE, (C18:0-C18:2)PE, and (C16:0-C18:2)PE as the major molecular species. Ox liver PE was rich in the species (C18:0-C18:1)PE, (C18:0-C20:4)PE, and (C18:0-C18:2)PE. Finally, krill oil which was particularly rich in (C16:0(alkyl)-C22:6(acyl))plasmanylethanolamine (PakE), (C16:0-C22:6)PE, and (C16:0-C20:5)PE, seemed to be an interesting potential source for supplementation of food with eicosapentaenoic acid and docosahexaenoic acid.

  6. Simultaneous determination of kasugamycin and validamycin-A residues in cereals by consecutive solid-phase extraction combined with liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Zhang, Hong; Wang, Chenchen; Li, Huidong; Nie, Yan; Fang, Liping; Chen, Zilei

    2018-03-01

    Two polar aminoglycosides, kasugamycin and validamycin-A, were determined in cereals (brown rice, wheat and corn) by high-performance liquid chromatography-tandem mass spectrometry. The analytes were extracted from samples using methanol and water (70:30, v/v) at pH 5.5, purified using both a hydrophilic-hydrophobic-balanced cartridge and a strong cation-exchange cartridge, and then analysed using multiple reaction monitoring in positive electrospray ionisation mode with a special ReproSil 100 C 18 high-performance liquid chromatography column. This newly proposed method yielded good sensitivity and excellent chromatographic performance. The limits of quantification for kasugamycin and validamycin-A were 4.1 µg/kg and 1.0 µg/kg, respectively. The recoveries for both compounds at three fortification levels (4, 100 and 500 µg/kg for kasugamycin; 1, 10 and 100 µg/kg for validamycin-A) ranged from 75% to 110%, and the relative standard deviations were below 15%.

  7. Investigation of the effect of plasma albumin levels on regorafenib-induced hepatotoxicity using a validated liquid chromatography-tandem mass spectrometry method.

    Science.gov (United States)

    Pang, Yi Yun; Tan, Yeong Lan; Ho, Han Kiat

    2017-09-01

    Regorafenib is an oral multikinase inhibitor indicated for metastatic colorectal cancer and gastrointestinal stromal tumour. Due to its extensive plasma protein binding and low calculated hepatic extraction ratio, the hepatotoxicity observed with usage of the drug may be related to its plasma exposure. To investigate the highly dynamic free:bound drug concentration for regorafenib in the plasma, a bioanalytical liquid chromatography-tandem mass spectrometric assay was developed and validated in human plasma. The concentration range of the assay was 2-1000ng/mL. Sample preparation was via protein precipitation using acetonitrile with sorafenib as the internal standard. The supernatant was injected into an ultra-performance liquid chromatographic system coupled to a triple quadrupole mass spectrometer. The analytes were separated on an AQUITY UPLC BEH C 18 column (120Å, 1.7μm, 2.1mm×50mm) and eluted with a gradient elution system. The ions were detected in multiple reaction monitoring mode. The linearity, lower limit of quantification, intra-day and inter-day precision and accuracy conformed to FDA guidelines. The validated method was successfully applied to determine the effect of albumin levels in plasma on the extent of protein binding of regorafenib. The results indicated that physiologically-relevant levels of albumin were found to have no significant effect on the extent of protein binding of regorafenib, hence imposing minimal effect on drug disposition. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Identification of marker proteins for the adulteration of meat products with soybean proteins by multidimensional liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Leitner, Alexander; Castro-Rubio, Florentina; Marina, Maria Luisa; Lindner, Wolfgang

    2006-09-01

    Soybean proteins are frequently added to processed meat products for economic reasons and to improve their functional properties. Monitoring of the addition of soybean protein to meat products is of high interest due to the existence of regulations forbidding or limiting the amount of soybean proteins that can be added during the processing of meat products. We have used chromatographic prefractionation on the protein level by perfusion liquid chromatography to isolate peaks of interest from extracts of soybean protein isolate (SPI) and of meat products containing SPI. After enzymatic digestion using trypsin, the collected fractions were analyzed by nanoflow liquid chromatography-tandem mass spectrometry. Several variants and subunits of the major seed proteins, glycinin and beta-conglycinin, were identified in SPI, along with two other proteins. In soybean-protein-containing meat samples, different glycinin A subunits could be identified from the peak discriminating between samples with and without soybean proteins added. Among those, glycinin G4 subunit A4 was consistently found in all samples. Consequently, this protein (subunit) can be used as a target for new analytical techniques in the course of identifying the addition of soybean protein to meat products.

  9. Liquid chromatography tandem mass spectrometry determination of chemical markers and principal component analysis of Vitex agnus-castus L. fruits (Verbenaceae) and derived food supplements.

    Science.gov (United States)

    Mari, Angela; Montoro, Paola; Pizza, Cosimo; Piacente, Sonia

    2012-11-01

    A validated analytical method for the quantitative determination of seven chemical markers occurring in a hydroalcoholic extract of Vitex agnus-castus fruits by liquid chromatography electrospray triple quadrupole tandem mass spectrometry (LC/ESI/(QqQ)MSMS) is reported. To carry out a comparative study, five commercial food supplements corresponding to hydroalcoholic extracts of V. agnus-castus fruits were analysed under the same chromatographic conditions of the crude extract. Principal component analysis (PCA), based only on the variation of the amount of the seven chemical markers, was applied in order to find similarities between the hydroalcoholic extract and the food supplements. A second PCA analysis was carried out considering the whole spectroscopic data deriving from liquid chromatography electrospray linear ion trap mass spectrometry (LC/ESI/(LIT)MS) analysis. High similarity between the two PCA was observed, showing the possibility to select one of these two approaches for future applications in the field of comparative analysis of food supplements and quality control procedures. Copyright © 2012 Elsevier B.V. All rights reserved.

  10. Analysis of Veterinary Drug and Pesticide Residues Using the Ethyl Acetate Multiclass/Multiresidue Method in Milk by Liquid Chromatography-Tandem Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Husniye Imamoglu

    2016-01-01

    Full Text Available A rapid and simple multiclass, ethyl acetate (EtOAc multiresidue method based on liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS detection was developed for the determination and quantification of 26 veterinary drugs and 187 total pesticide residues in milk. Sample preparation was a simple procedure based on liquid–liquid extraction with ethyl acetate containing 0.1% acetic acid, followed by centrifugation and evaporation of the supernatant. The residue was dissolved in ethyl acetate with 0.1% acetic acid and centrifuged prior to LC-MS/MS analysis. Chromatographic separation of analytes was performed on an Inertsil X-Terra C18 column with acetic acid in methanol and water gradient. The repeatability and reproducibility were in the range of 2 to 13% and 6 to 16%, respectively. The average recoveries ranged from 75 to 120% with the RSD (n=18. The developed method was validated according to the criteria set in Commission Decision 2002/657/EC and SANTE/11945/2015. The validated methodology represents a fast and cheap alternative for the simultaneous analysis of veterinary drug and pesticide residues which can be easily extended to other compounds and matrices.

  11. Sample preparation for large-scale bioanalytical studies based on liquid chromatographic techniques.

    Science.gov (United States)

    Medvedovici, Andrei; Bacalum, Elena; David, Victor

    2018-01-01

    Quality of the analytical data obtained for large-scale and long term bioanalytical studies based on liquid chromatography depends on a number of experimental factors including the choice of sample preparation method. This review discusses this tedious part of bioanalytical studies, applied to large-scale samples and using liquid chromatography coupled with different detector types as core analytical technique. The main sample preparation methods included in this paper are protein precipitation, liquid-liquid extraction, solid-phase extraction, derivatization and their versions. They are discussed by analytical performances, fields of applications, advantages and disadvantages. The cited literature covers mainly the analytical achievements during the last decade, although several previous papers became more valuable in time and they are included in this review. Copyright © 2017 John Wiley & Sons, Ltd.

  12. The development of a high performance liquid chromatograph with a sensitive on-stream radioactivity monitor for the analysis of 3H- and 14C-labelled gibberellins

    International Nuclear Information System (INIS)

    Reeve, D.R.; Yokota, T.; Nash, L.; Crozier, A.

    1976-01-01

    The development of a high performance liquid chromatograph for the separation of gibberellins is described. The system combines high efficiency, peak capacity, and sample capacity with rapid speed of analysis. In addition, the construction details of a sensitive on-stream radioactivity monitor are outlined. The overall versatility of the chromatograph has been demonstrated by the separation of a range of 3 H- and 14 C-labelled gibberellins and gibberellin precursors. The system also has considerable potential for the analysis of abscisic acid and acidic and neutral indoles. (author)

  13. Stability-indicating liquid Chromatographic assaymethod for Opthalmic solutions containing combination of Dexamethasone and Chloramphenicol

    International Nuclear Information System (INIS)

    Rao, R.M.; Al-Ashban, R.M.; Shah, A.H.

    2004-01-01

    A selective high-performance chromatographic procedure for the stability monitoring of ophthalmic solutions containing a combination of dexamethasone and chloramphenicolis demonstrated. The separation of the active components and the degradation product of chloramphenicol (1-amino-1-(4-nitrophenyl)-propane-1, 3diol) was achieved on a u-Bondapack C-18 column ( 5 um, 300 mm x 3.9 mm) maintained at ambient temperature (15-20C) by utilizing a mobile phase consisting acidified water (5% actified water with glacial acetic acid ) : acetonitrile : triethyl amine 700 : 300 : 2and pH was adjusted to 5.0 by using 10 M Na OH. The flow rate was 1.5 ml min-1; and elutes were followed with UV-detection at 254 nm. Complete resolution of dexamethasone, chloramphenicol and its hydrolytic product could be attained. The sensitivity, accuracy and specificity were tested. The method was successfully applied in post-marketing stability of the commercial batches of ophthalmic solutions. (author)

  14. High Performance Liquid Chromatographic Analysis of Almotriptan Malate in Bulk and Tablets

    Directory of Open Access Journals (Sweden)

    Chandra Bala Sekaran

    2013-02-01

    Full Text Available Purpose: A simple RP-HPLC method has been developed and validated for the determination of almotriptan malate (ATM in bulk and tablets. Methods: Chromatographic separation of ATM was achieved by using a Thermo Scientific C18 column. A Mobile phase containing a mixture of methanol, water and acetic acid (4:8:0.1 v/v was pumped at the flow rate of 1 mL/min. Detection was performed at 227 nm. According to ICH guidelines, the method was validated. Results: The calibration curve was linear in the concentration range 5–60 μg/mL for the ATM with regression coefficient 0.9999. The method was precise with RSD <1.2%. Excellent recoveries of 99.60 - 100.80% proved the accuracy of the method. The limits of detection and quantification were found to be 0.025 and 0.075 μg/mL, respectively. Conclusion: The method was successfully applied for the quantification of ATM in tablets with acceptable accuracy and precision.

  15. Simple fluorimetric liquid chromatographic method for the analysis of undecylenic acid and zinc undecylenate in pharmaceutical preparations.

    Science.gov (United States)

    Lin, Ming-Chun; Wu, Hsin-Lung; Kou, Hwang-Shang; Wu, Shou-Mei

    2006-06-30

    A simple and selective liquid chromatographic method is described for the analysis of undecylenic acid (UA) and zinc undecylenate (ZnUA) in pharmaceutical preparations. The method is based on the derivatization of the analytes extracted from various samples with 2-(2-naphthoxy)ethyl 2-(piperidino)ethanesulfonate. The resulting derivative was analyzed by liquid chromatography with fluorimetric detection. The quantitation of the method is in the range of 3.0-50.0 microM UA with a detection limit of about 0.3 microM (S/N = 3 with 10 microl injection). We found that acetonitrile is a selective solvent for differentially dissolving UA from coexisted ZnUA in compound formulation. This results in the specific analysis of UA in the presence of ZnUA and simply analyzing the coexisted ZnUA by the value of total UA (UA+ZnUA) minus that of UA. Application of the method to the analysis of undecylenic acid and zinc undecylenate in ointment, powder and solution preparations proved feasible.

  16. Characterization of Chinese rice wine taste attributes using liquid chromatographic analysis, sensory evaluation, and an electronic tongue.

    Science.gov (United States)

    Yu, HaiYan; Zhao, Jie; Li, Fenghua; Tian, Huaixiang; Ma, Xia

    2015-08-01

    To evaluate the taste characteristics of Chinese rice wine, wine samples sourced from different vintage years were analyzed using liquid chromatographic analysis, sensory evaluation, and an electronic tongue. Six organic acids and seventeen amino acids were measured using high performance liquid chromatography (HPLC). Five monosaccharides were measured using anion-exchange chromatography. The global taste attributes were analyzed using an electronic tongue (E-tongue). The correlations between the 28 taste-active compounds and the sensory attributes, and the correlations between the E-tongue response and the sensory attributes were established via partial least square discriminant analysis (PLSDA). E-tongue response data combined with linear discriminant analysis (LDA) were used to discriminate the Chinese rice wine samples sourced from different vintage years. Sensory evaluation indicated significant differences in the Chinese rice wine samples sourced from 2003, 2005, 2008, and 2010 vintage years in the sensory attributes of harmony and mellow. The PLSDA model for the taste-active compounds and the sensory attributes showed that proline, fucose, arabinose, lactic acid, glutamic acid, arginine, isoleucine, valine, threonine, and lysine had an influence on the taste characteristic of Chinese rice wine. The Chinese rice wine samples were all correctly classified using the E-tongue and LDA. The electronic tongue was an effective tool for rapid discrimination of Chinese rice wine. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Evaluation of highly polar ionic liquid gas chromatographic column for the determination of the fatty acids in milk fat.

    Science.gov (United States)

    Delmonte, Pierluigi; Fardin-Kia, Ali Reza; Kramer, John K G; Mossoba, Magdi M; Sidisky, Len; Tyburczy, Cynthia; Rader, Jeanne I

    2012-04-13

    The SLB-IL111, a new ionic liquid capillary column for gas chromatography available from Supelco Inc., was recently shown to provide enhanced separation of unsaturated geometric and positional isomers of fatty acid (FAs) when it was compared to cyanopropylsiloxane (CPS) columns currently recommended for the analysis of fatty acid methyl esters (FAMEs). A 200 m SLB-IL111 capillary column, operated under a combined temperature and eluent flow gradient, was successfully used to resolve most of the FAs contained in milk fat in a single 80 min chromatographic separation. The selected chromatographic conditions provided a balanced, simultaneous separation of short-chain (from 4:0), long-chain polyunsaturated fatty acids (PUFAs), and most of the unsaturated FA positional/geometric isomers contained in milk fat. Among the monounsaturated fatty acids (MUFAs), these conditions separated t11-18:1 and t10-18:1 FAs, the two most abundant trans fatty acids (t-FA) contained in most dairy products. These t-FAs reportedly have different biological activities. The conjugated linoleic acid (CLA) isomers commonly found in dairy products were separated from each other, including t7,c9-18:2 from c9,t11-18:2, which eliminated the need for their complementary silver ion HPLC analysis. The application of the SLB-IL111 column provided a complementary elution profile of FAMEs to those obtained by CPS columns, allowing for a more comprehensive FA analysis of total milk fat. The FAMEs were identified by the use of available reference materials, previously synthesized and characterized reference mixtures, and prior separations of the milk fat FAMEs by silver ion chromatography based on the number/geometry of double bonds. Published by Elsevier B.V.

  18. New liquid chromatographic-chemometric approach for the determination of sunset yellow and tartrazine in commercial preparation.

    Science.gov (United States)

    Dinç, Erdal; Aktaş, A Hakan; Ustündağ, Ozgür

    2005-01-01

    A new liquid chromatographic (LC)-chemometric approach was developed for the determination of sunset yellow (SUN) and tartrazine (TAR) in commercial preparations. This approach uses LC and chemometric calibration methods, i.e., classical least-squares (CLS), principal component regression (PCR), and partial-least squares (PLS), simultaneously. The combined LC-chemometric approaches, denoted as LC-CLS, LC-PCR, and LC-PLS, are based on photodiode array (PDA) detection at multiple wavelengths. Optimum chromatographic separation of SUN and TAR with allura red as the internal standard (IS) was obtained by using a Waters Symmetry C18 column, 5 microm, 4.6 x 250 mm, and 0.2 M acetate buffer (pH 5)-acetonitrile-methano-bidistilled water (55 + 20 + 15 + 10, v/v) as the mobile phase at a flow rate of 1.9 mL/min. The LC data sets consisting of the ratios of analyte peak areas to the IS peak area were obtained by using PDA detection at 5 wavelengths (465, 470, 475, 480, and 485 nm). LC-chemometric calibrations for SUN and TAR were separately constructed by using the relationship between the peak-area ratio and the training sets for each colorant. LC-chemometric approaches were tested for different synthetic mixtures containing SUN and TAR in the presence of the IS. These LC-chemometric calibrations were applied to a commercial preparation of the 2 colorants. The experimental results of the LC-chemometric approaches were compared with those obtained by a developed classical LC method using single-wavelength detection.

  19. Liquid-phase microextraction for simultaneous chromatographic analysis of three antidepressant drugs in plasma

    Directory of Open Access Journals (Sweden)

    Carlos Eduardo Dobrovolskni Porto

    2012-01-01

    Full Text Available A method using Liquid Phase Microextraction for simultaneous detection of citalopram (CIT, paroxetine (PAR and fluoxetine (FLU, using venlafaxine as internal standard, in plasma by high performance liquid chromatography with fluorescence detection was developed. The linearity was evaluated between 5.0 and 500 ng mL-1 (r > 0.99 and the limit of quantification was 2.0, 3.0 and 5.0 ng mL-1 for CIT, PAR and FLU, respectively. Therefore, it can be applied to therapeutic drug monitoring, pharmacokinetics or bioavailability studies and its advantages are that it necessary relatively inexpensive equipment and sample preparation techniques.

  20. Characterization of Isomeric Glycans by Reversed Phase Liquid Chromatography-Electronic Excitation Dissociation Tandem Mass Spectrometry

    Science.gov (United States)

    Tang, Yang; Wei, Juan; Costello, Catherine E.; Lin, Cheng

    2018-04-01

    The occurrence of numerous structural isomers in glycans from biological sources presents a severe challenge for structural glycomics. The subtle differences among isomeric structures demand analytical methods that can provide structural details while working efficiently with on-line glycan separation methods. Although liquid chromatography-tandem mass spectrometry (LC-MS/MS) is a powerful tool for mixture analysis, the commonly utilized collision-induced dissociation (CID) method often does not generate a sufficient number of fragments at the MS2 level for comprehensive structural characterization. Here, we studied the electronic excitation dissociation (EED) behaviors of metal-adducted, permethylated glycans, and identified key spectral features that could facilitate both topology and linkage determinations. We developed an EED-based, nanoscale, reversed phase (RP)LC-MS/MS platform, and demonstrated its ability to achieve complete structural elucidation of up to five structural isomers in a single LC-MS/MS analysis. [Figure not available: see fulltext.

  1. Determination of dapsone in meat and milk by liquid chromatography tandem mass spectrometry

    International Nuclear Information System (INIS)

    Hadjigeorgiou, M.; Papachrysostomou, Ch.; Theodorou, Z.; Kanari, P.; Constantinou, S.

    2009-01-01

    Within the EU the use of dapsone (4,4-diaminodiphenylsulfone) is prohibited in food-producing animals and consequently it's included in the Annex IV of the Directive 90/2377/EC. A quantitative confirmatory method has been developed and validated according to the criteria defined in the Commission Decision 2002/657/EC, for the determination of dapsone in meat and milk. Samples, after homogenization in alkaline conditions and organic solvent extraction, were purified on silica gel solid phase extraction cartridges. The eluate was evaporated and redissolved in mobile phase and was analysed by liquid chromatography tandem mass spectrometry (LC-MS/MS) in positive electrospray ionisation (ESI) using deuterium labelled Sulphadimidine-d7 as internal standard. The calculated value for, decision limit, CCα is 0.12 μg kg -1 , and the detection capability; CCβ value is 0.16 μg kg -1

  2. Determination of clarithromycin in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Jiang, Yao; Wang, Jiang; Li, Hao; Wang, Yingwu; Gu, Jingkai

    2007-03-12

    A rapid and sensitive method has been developed for the determination of clarithromycin in human plasma with liquid chromatography-tandem mass spectrometry. Clarithromycin and the internal standard, telmisartan were precipitated from the matrix (50 microl) with 200 microl acetonitrile and separated by HPLC using formic acid:10 mM ammonium acetate:methanol (1:99:400, v/v/v) as the mobile phase. The assay based on detection by electrospray positive ionization mass spectrometry in the multiple-reaction monitoring mode was finished within 2.4 min. Linearity was over the concentration range 10-5000 ng/ml with a limit of detection of 0.50 ng/ml. Intra- and inter-day precision measured as relative standard deviation were bioequivalence study of two tablet formulations of clarithromycin.

  3. Liquid Chromatography-Tandem Mass Spectrometry: An Emerging Technology in the Toxicology Laboratory.

    Science.gov (United States)

    Zhang, Yan Victoria; Wei, Bin; Zhu, Yu; Zhang, Yanhua; Bluth, Martin H

    2016-12-01

    In the last decade, liquid chromatography-tandem mass spectrometry (LC-MS/MS) has seen enormous growth in routine toxicology laboratories. LC-MS/MS offers significant advantages over other traditional testing, such as immunoassay and gas chromatography-mass spectrometry methodologies. Major strengths of LC-MS/MS include improvement in specificity, flexibility, and sample throughput when compared with other technologies. Here, the basic principles of LC-MS/MS technology are reviewed, followed by advantages and disadvantages of this technology compared with other traditional techniques. In addition, toxicology applications of LC-MS/MS for simultaneous detection of large panels of analytes are presented. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Recent advances of liquid chromatography-(tandem) mass spectrometry in clinical and forensic toxicology.

    Science.gov (United States)

    Peters, Frank T

    2011-01-01

    Liquid chromatography (LC) coupled to mass spectrometry (MS) or tandem mass spectrometry (MS/MS) has become increasingly important in clinical and forensic toxicology as well as doping control and is now a robust and reliable technique for routine analysis in these fields. In recent years, methods for LC-MS(/MS)-based systematic toxicological analysis using triple quadrupole or ion trap instruments have been considerably improved and a new screening approach based on high-resolution MS analysis using benchtop time-of-flight MS instruments has been developed. Moreover, many applications for so-called multi-target screening and/or quantification of drugs, poisons, and or their metabolites in various biomatrices have been published. The present paper will provide an overview and discuss these recent developments focusing on the literature published after 2006. Copyright © 2010 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  5. Analysis of bromate in drinking water using liquid chromatography-tandem mass spectrometry without sample pretreatment.

    Science.gov (United States)

    Kosaka, Koji; Asami, Mari; Takei, Kanako; Akiba, Michihiro

    2011-01-01

    An analytical method for determining bromate in drinking water was developed using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The (18)O-enriched bromate was used as an internal standard. The limit of quantification (LOQ) of bromate was 0.2 µg/L. The peak of bromate was separated from those of coexisting ions (i.e., chloride, nitrate and sulfate). The relative and absolute recoveries of bromate in two drinking water samples and in a synthesized ion solution (100 mg/L chloride, 10 mg N/L nitrate, and 100 mg/L sulfate) were 99-105 and 94-105%, respectively. Bromate concentrations in 11 drinking water samples determined by LC-MS/MS were water without sample pretreatment.

  6. [Determination of amitrole in agricultural products by high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Li, Li; Fu, Jian; Gao, Hongliang; Ren, Haitao; Lou, Xishan; Guan, Lihui

    2010-03-01

    A high performance liquid chromatography-tandem mass spectrometry method (HPLC-MS/MS) was developed for the analysis of amitrole residues in agricultural products. The samples were extracted by 25% acetone for wheat, fish, pork and liver samples, 1% acetic acid-25% acetone for maize and peanut samples, 1% acetic acid solution for honeysuckle, the powder of ginger, the powder of bunge prickly ash and tea leaves samples, 1% acetic acid solution-dichloromethane for apple, pineapple, spinach, carrot, perilla leaves samples, respectively, followed by liquid-liquid extraction with dichloromethane. The samples were then cleaned up by PCX or Envi-Carb solid-phase extraction cartridge. The amitrole was determined and confirmed by HPLC-MS/MS. The results showed a linear relationship in the range of 0.005 -0.1 mg/kg for amitrole. The correlation coefficient was 0.999 7. The average recoveries of amitrole in wheat, maize, peanut, pineapple, apple, carrot, spinach, pork, the powder of ginger, the powder of bunge prickly ash, perilla, liver, fish, honeysuckle and tea were 67.5% - 98.1%. The relative standard deviations (RSDs) were 1.0% - 9.8%. The limits of quantitation were 10 microg/kg for wheat, maize, peanut, pineapple, apple, carrot, spinach, pork, perilla, liver, fish, honeysuckle and 20 microg/kg for the powder of bunge prickly ash, the powder of ginger and tea, respectively. The method is simple, sensitive and accurate.

  7. Design of self-cooled, liquid-metal blankets for tokamak and tandem mirror reactors

    International Nuclear Information System (INIS)

    Cha, Y.S.; Gohar, Y.; Hassanein, A.M.; Majumdar, S.; Picologlou, B.F.; Smith, D.L.; Szo, D.K.

    1985-01-01

    Results of the self-cooled, liquid-metal blanket design from the Blanket Comparison and Selection Study (BCSS) are summarized. The objectives of the BCSS project are to define a small number (about three) of blanket concepts that should be the focus of the blanket research and development (RandD) program, identify and prioritize the critical issues for the leading blanket concepts, and provide technical input necessary to develop a blanket RandD program plan. Two liquid metals (lithium and lithium-lead (17Li-83Pb)) and three structural materials (primary candidate alloy (PCA), ferritic steel (FS) (HT-9), and vanadium alloy (V-15 Cr-5 Ti)) are included in the evaluations for both tokamaks and tandem mirror reactors (TMRs). TMR is of the tube configuration similar to the Mirror Advanced Reactor Study design. Analyses were performed in the following generic areas for each blanket concept: MHD, thermal hydraulics, stress, neutronics, and tritium recovery. Integral analyses were performed to determine the design window for each blanket design. The Li/Li/V blanket for tokamak and the Li/Li/V, LiPb/LiPb/V, and Li/Li/HT-9 blankets for the TMR are judged to be top-rated concepts. Because of its better thermophysical properties and more uniform nuclear heating profile, liquid lithium is a better coolant than liquid 17Li83Pb. From an engineering point of view, vanadium alloy is a better structural material than either FS or PCA since the former has both a higher allowable structural temperature and a higher allowable coolant/structure interface temperature than the latter. Critical feasibility issues and design constraints for the self-cooled, liquid-metal blanket concepts are identified and discussed

  8. Profiling ABA metabolites in Nicotiana tabacum L. leaves by ultra-performance liquid chromatography–electrospray tandem mass spectrometry

    Czech Academy of Sciences Publication Activity Database

    Turečková, Veronika; Novák, Ondřej; Strnad, Miroslav

    2009-01-01

    Roč. 80, č. 1 (2009), s. 390-399 ISSN 0039-9140 R&D Projects: GA AV ČR KAN200380801 Institutional research plan: CEZ:AV0Z50380511 Keywords : Abscisic acid * Ultra-performance liquid chromatography (UPLC) * Tandem mass spectrometry (MS/MS) Subject RIV: EC - Immunology Impact factor: 3.290, year: 2009

  9. Solid phase extraction for removal of matrix effects in lipophilic marine toxin analysis by liquid chromatography-tandem mass spectrometry

    NARCIS (Netherlands)

    Gerssen, A.; McElhinney, M.; Mulder, P.P.J.; Bire, R.; Hess, P.; Boer, de J.

    2009-01-01

    The potential of solid phase extraction (SPE) clean-up has been assessed to reduce matrix effects (signal suppression or enhancement) in the liquid chromatography-tandem mass spectrometry (LC¿MS/MS) analysis of lipophilic marine toxins. A large array of ion-exchange, silica-based, and mixed-function

  10. Solid phase extraction for removal of matrix effects in lipophilic marine toxin analysis by liquid chromatography-tandem mass spectrometry

    NARCIS (Netherlands)

    Gerssen, A.; McElhinney, A. M.; Mulder, P.P.J.; Bire, L.; Hess, P.; de Boer, J.

    2009-01-01

    The potential of solid phase extraction (SPE) clean-up has been assessed to reduce matrix effects (signal suppression or enhancement) in the liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis of lipophilic marine toxins. A large array of ion-exchange, silica-based, and mixed-function

  11. Simultaneous determination of estrogens and progestogens in honey using high performance liquid chromatography-tandem mass spectrometry

    Science.gov (United States)

    This work describes the development and validation of a method for the simultaneous determination of 13 estrogens and progestogens in honey by high performance liquid chromatography-tandem mass spectrometry. The target compounds were preconcentrated by solid phase extraction. Pretreatment variables ...

  12. Liquid chromatography-tandem mass spectrometry assay for the quantification of free and total sialic acid in human cerebrospinal fluid.

    NARCIS (Netherlands)

    Ham, M. van der; Koning, T.J. de; Lefeber, D.J.; Fleer, A.; Prinsen, B.H.; Sain-van der Velden, M.G. de

    2010-01-01

    BACKGROUND: Analysis of sialic acid (SA) metabolites in cerebrospinal fluid (CSF) is important for clinical diagnosis. In the present study, a high-performance liquid chromatography-tandem mass spectrometry (HPLC/MS/MS) method for free sialic acid (FSA) and total sialic acid (TSA) in human CSF was

  13. Liquid chromatography coupled with tandem mass spectrometry for the quantitative analysis of anticancer drugs in biological matrices

    NARCIS (Netherlands)

    Stokvis, Ellen

    2004-01-01

    In this thesis, the development and validation of liquid chromatography tandem mass spectrometric (LC-MS/MS) methods for the quantitative bioanalysis of anticancer drugs are described. The monitoring of these drugs in biological fluids and tissues is important during both pre-clinical and clinical

  14. High Speed Liquid Chromatographic Determination of Total Aromatics in Enamel and Lacquer Solvents.

    Science.gov (United States)

    Esposito, G. G.

    Aromatic solvents possess the strongest solvency of the hydrogen types, but various air pollution control districts have established maximum limits on the amount that may be present in organic coatings. In the proposed procedure, high efficiency liquid chromatography is used to determine total aromatics in enamels and lacquer thinners, their…

  15. Evaluation of the phase ratio for three C18 high performance liquid chromatographic columns.

    Science.gov (United States)

    Caiali, Edvin; David, Victor; Aboul-Enein, Hassan Y; Moldoveanu, Serban C

    2016-02-26

    For a chromatographic column, phase ratio Φ is defined as the ratio between the volume of the stationary phase Vst and the void volume of the column V0, and it is an important parameter characterizing the HPLC process. Although apparently simple, the evaluation of Φ presents difficulties because there is no sharp boundary between the mobile phase and the stationary phase. In addition, the boundary depends not only on the nature of the stationary phase, but also on the composition of the mobile phase. In spite of its importance, phase ratio is seldom reported for commercially available HPLC columns and the data typically provided by the vendors about the columns do not provide key information that would allow the calculation of Φ based on Vst and V0 values. A different procedure for the evaluation of Φ is based on the following formula: log k'j=a log Kow,j+log Φ, where k'j is the retention factor for a compound j that must be a hydrocarbon, Kow,j is the octanol/water partition coefficient, and a is a proportionality constant. Present study describes the experimental evaluation of Φ based on the measurement of k'j for the compounds in the homologous series between benzene and butylbenzene for three C18 columns: Gemini C18, Luna C18 both with 5 μm particles, and a Chromolith Performance RP-18. The evaluation was performed for two mobile phase systems at different proportions of methanol/water and acetonitrile/water. The octanol/water partition coefficients were obtained from the literature. The results obtained in the study provide further support for the new procedure for the evaluation of phase ratio. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Sample preparation for liquid chromatographic analysis of phytochemicals in biological fluids.

    Science.gov (United States)

    Oh, Ju-Hee; Lee, Young-Joo

    2014-01-01

    Natural products have been used traditionally for the treatment and prevention of diseases for thousands of years and are nowadays consumed as dietary supplements and herbal medicine. To ensure the safe and effective use of these herbal products, information about bioavailability of active compounds in plasma or target tissues should be provided via validated analytical methods combined with appropriate sampling methods. To provide comprehensive and abridged information about sample preparation methods for the quantification of phytochemicals in biological samples using liquid chromatography analysis. Sample pre-treatment procedures used in analytical methods for in vivo pharmacokinetic studies of natural compounds or herbal medicines were reviewed. These were categorised according to the biological matrices (plasma, bile, urine, faeces and tissues) and sample clean-up processes (protein precipitation, liquid-liquid extraction and solid-phase extraction). Although various kinds of sample pre-treatment methods have been developed, liquid-liquid extraction is still widely used and solid-phase extraction is becoming increasingly popular because of its efficiency for extensive clean up of complex matrix samples. However, protein precipitation is still favoured due to its simplicity. Sample treatment for phytochemical analysis in biological fluids is an indispensable and critical step to obtain high quality results. This step could dominate the overall analytical process because both the duration of the process as well as the reliability of the data depend in large part on its efficiency. Thus, special attention should be given to the choice of a proper sample treatment method that targets analytes and their biomatrix. Copyright © 2013 John Wiley & Sons, Ltd.

  17. Simultaneous quantitative analysis of eight vitamin D analogues in milk using liquid chromatography–tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Gomes, Fabio P.; Shaw, P. Nicholas; Whitfield, Karen; Hewavitharana, Amitha K., E-mail: a.hewavitharana@pharmacy.uq.edu.au

    2015-09-03

    Milk is an important source of nutrients for various risk populations, including infants. The accurate measurement of vitamin D in milk is necessary to provide adequate supplementation advice for risk groups and to monitor regulatory compliance. Currently used liquid chromatography–tandem mass spectrometry (LC–MS/MS) methods are capable of measuring only four analogues of vitamin D in unfortified milk. We report here an accurate quantitative analytical method for eight analogues of vitamin D: Vitamin D{sub 2} and D{sub 3} (D{sub 2} and D{sub 3}), 25-hydroxy D{sub 2} and D{sub 3}, 24,25-dihydroxy D{sub 2} and D{sub 3}, and 1,25-dihydroxyD{sub 2} and D{sub 3}. In this study, we compared saponification and protein precipitation for the extraction of vitamin D from milk and found the latter to be more effective. We also optimised the pre-column derivatisation using 4-phenyl-l,2,4-triazoline-3,5-dione (PTAD), to achieve the highest sensitivity and accuracy for all major vitamin D forms in milk. Chromatography was optimised to reduce matrix effects such as ion-suppression, and the matrix effects were eliminated using co-eluting stable isotope labelled internal standards for the calibration of each analogue. The analogues, 25-hydroxyD{sub 3} (25(OH)D{sub 3}) and its epimer (3-epi-25(OH)D{sub 3}) were chromatographically resolved, to prevent over-estimation of 25(OH)D{sub 3}. The method was validated and subsequently applied for the measurement of total vitamin D levels in human, cow, mare, goat and sheep milk samples. The detection limits, repeatability standard deviations, and recovery ranges were from 0.2 to 0.4 femtomols, 6.30–13.5%, and 88.2–105%, respectively. - Highlights: • Simultaneous, femtomole level, quantification of 8 vitamin D analogues in milk. • Optimisation of the PTAD derivatisation as a pre-column method. • Optimisation of the separation to minimise ion suppression effects, and to separate out an inactive form of vitamin D. • Comparison

  18. Simultaneous quantitative analysis of eight vitamin D analogues in milk using liquid chromatography–tandem mass spectrometry

    International Nuclear Information System (INIS)

    Gomes, Fabio P.; Shaw, P. Nicholas; Whitfield, Karen; Hewavitharana, Amitha K.

    2015-01-01

    Milk is an important source of nutrients for various risk populations, including infants. The accurate measurement of vitamin D in milk is necessary to provide adequate supplementation advice for risk groups and to monitor regulatory compliance. Currently used liquid chromatography–tandem mass spectrometry (LC–MS/MS) methods are capable of measuring only four analogues of vitamin D in unfortified milk. We report here an accurate quantitative analytical method for eight analogues of vitamin D: Vitamin D_2 and D_3 (D_2 and D_3), 25-hydroxy D_2 and D_3, 24,25-dihydroxy D_2 and D_3, and 1,25-dihydroxyD_2 and D_3. In this study, we compared saponification and protein precipitation for the extraction of vitamin D from milk and found the latter to be more effective. We also optimised the pre-column derivatisation using 4-phenyl-l,2,4-triazoline-3,5-dione (PTAD), to achieve the highest sensitivity and accuracy for all major vitamin D forms in milk. Chromatography was optimised to reduce matrix effects such as ion-suppression, and the matrix effects were eliminated using co-eluting stable isotope labelled internal standards for the calibration of each analogue. The analogues, 25-hydroxyD_3 (25(OH)D_3) and its epimer (3-epi-25(OH)D_3) were chromatographically resolved, to prevent over-estimation of 25(OH)D_3. The method was validated and subsequently applied for the measurement of total vitamin D levels in human, cow, mare, goat and sheep milk samples. The detection limits, repeatability standard deviations, and recovery ranges were from 0.2 to 0.4 femtomols, 6.30–13.5%, and 88.2–105%, respectively. - Highlights: • Simultaneous, femtomole level, quantification of 8 vitamin D analogues in milk. • Optimisation of the PTAD derivatisation as a pre-column method. • Optimisation of the separation to minimise ion suppression effects, and to separate out an inactive form of vitamin D. • Comparison of saponification and protein precipitation for their extraction

  19. Quantitation of clevidipine in dog blood by liquid chromatography tandem mass spectrometry: application to a pharmacokinetic study.

    Science.gov (United States)

    Wei, Huihui; Gu, Yuan; Liu, Yanping; Chen, Yong; Liu, Changxiao; Si, Duanyun

    2014-11-15

    Clevidipine, a vascular selective calcium channel antagonist of the dihydropyridine class, is rapidly metabolized by ester hydrolysis because of incorporation of an ester linkage into the drug molecule. To characterize its pharmacokinetic profiles in dogs, a simple, rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for quantitation of clevidipine in dog blood. After one-step protein precipitation with methanol, the chromatographic separation was carried out on an Ecosil C18 column (150mm×4.6mm, 5μm) with a gradient mobile phase consisting of methanol and 5mM ammonium formate at a flow rate of 0.5mL/min. The quantitation analysis was performed using multiple reaction monitoring (MRM) at the specific ion transitions of m/z 454.1 [M-H](-)→m/z 234.1 for clevidipine and m/z 256.1 [M-H](-)→m/z 227.1 for elofesalamide (internal standard) in the negative ion mode with electrospray ionization (ESI) source. This validated LC-MS/MS method showed good linearity over the range 0.5-100ng/mL with the lower limit of quantitation (LLOQ) of 0.5ng/mL together with the satisfied intra- and inter-day precision, accuracy, extraction recovery and matrix effect. Stability testing indicated that clevidipine in dog blood with the addition of denaturant methanol was stable on workbench for 1h, at -80°C for up to 30 days, and after three freeze-thaw cycles. Extracted samples were also observed to be stable over 24h in an auto-sampler at 4°C. The validated method has been successfully applied to a pharmacokinetic study of clevidipine injection to 8 healthy Beagle dogs following intravenous infusion at a flow rate of 5mg/h for 0.5h. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Determination of melamine in milk-based products and other food and beverage products by ion-pair liquid chromatography-tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Ibanez, Maria; Sancho, Juan V. [Research Institute for Pesticides and Water, University Jaume I, E-12071, Castellon (Spain); Hernandez, Felix, E-mail: felix.hernandez@qfa.uji.es [Research Institute for Pesticides and Water, University Jaume I, E-12071, Castellon (Spain)

    2009-09-01

    This paper describes a fast method for the sensitive and selective determination of melamine in a wide range of food matrices, including several milk-based products. The method involves an extraction with aqueous 1% trichloroacetic acid before the injection of the 10-fold diluted extract into the liquid chromatography-electrospray tandem mass spectrometry (LC-ESI-MS/MS) system, using labelled melamine as the internal standard. As melamine is present in aqueous media in the cationic form, the chromatographic separation in reversed-phase LC requires the use of anionic ion-pair reagents, such as tridecafluoroheptanoic acid (THFA). This allows a satisfactory chromatographic retention and peak shape in all the types of food samples investigated. The method has been validated in six food matrices (biscuit, dry pasta and four milk-based products) by means of recovery experiments in samples spiked at 1 and 5 mg kg{sup -1}. Average recoveries (n = 5) ranged from 77% to 100%, with excellent precision (RSDs lower than 5%) and limits of detection between 0.01 and 0.1 mg kg{sup -1}. In addition, accuracy and robustness of the method was proven in different soya-based matrices by means of quality control (QC) sample analysis. QC recoveries, at 1 and 2.5 mg kg{sup -1}, were satisfactory, ranging from 79% to 110%. The method developed in this work has been applied to the determination of melamine in different types of food samples. All detections were confirmed by acquiring two MS/MS transitions (127 > 85 for quantification; 127 > 68 for confirmation) and comparing their ion intensity ratio with that of reference standards. Accuracy of the method was also assessed by applying it to a milk-based product and a baking mix material as part of an EU proficiency test, in which highly satisfactory results were obtained.

  1. Determination of melamine in milk-based products and other food and beverage products by ion-pair liquid chromatography-tandem mass spectrometry

    International Nuclear Information System (INIS)

    Ibanez, Maria; Sancho, Juan V.; Hernandez, Felix

    2009-01-01

    This paper describes a fast method for the sensitive and selective determination of melamine in a wide range of food matrices, including several milk-based products. The method involves an extraction with aqueous 1% trichloroacetic acid before the injection of the 10-fold diluted extract into the liquid chromatography-electrospray tandem mass spectrometry (LC-ESI-MS/MS) system, using labelled melamine as the internal standard. As melamine is present in aqueous media in the cationic form, the chromatographic separation in reversed-phase LC requires the use of anionic ion-pair reagents, such as tridecafluoroheptanoic acid (THFA). This allows a satisfactory chromatographic retention and peak shape in all the types of food samples investigated. The method has been validated in six food matrices (biscuit, dry pasta and four milk-based products) by means of recovery experiments in samples spiked at 1 and 5 mg kg -1 . Average recoveries (n = 5) ranged from 77% to 100%, with excellent precision (RSDs lower than 5%) and limits of detection between 0.01 and 0.1 mg kg -1 . In addition, accuracy and robustness of the method was proven in different soya-based matrices by means of quality control (QC) sample analysis. QC recoveries, at 1 and 2.5 mg kg -1 , were satisfactory, ranging from 79% to 110%. The method developed in this work has been applied to the determination of melamine in different types of food samples. All detections were confirmed by acquiring two MS/MS transitions (127 > 85 for quantification; 127 > 68 for confirmation) and comparing their ion intensity ratio with that of reference standards. Accuracy of the method was also assessed by applying it to a milk-based product and a baking mix material as part of an EU proficiency test, in which highly satisfactory results were obtained.

  2. Ultra-high-pressure liquid chromatography tandem mass spectrometry determination of antidepressant and anxiolytic drugs in neonatal meconium and maternal hair.

    Science.gov (United States)

    Pichini, Simona; Cortes, Laura; Marchei, Emilia; Solimini, Renata; Pacifici, Roberta; Gomez-Roig, Mª Dolores; García-Algar, Oscar

    2016-01-25

    A procedure based on ultra-high-pressure liquid chromatography tandem mass spectrometry has been developed for the determination of 22 antidepressant and anxiolytic drugs ad metabolites in the three consecutive maternal hair segments representing the pregnancy trimesters and paired neonatal meconium samples. After hair washing with methyl alcohol and diethyl ether and subsequent addition of internal standards, hair samples were treated with 500 μl VMA-T M3 reagent for 1h at 100 °C. After cooling, 100 μl M3 extract were diluted with 400 μl water and a volume of 10 μl was injected into chromatographic system. Meconium samples were firstly treated with 1 ml methyl alcohol and the organic layer back-extracted twice with 1.5 ml of a mixture of ethylacetate:hexane (80:20, v/v). Chromatographic separation was achieved at ambient temperature using a reverse-phase column and a linear gradient elution with two solvents: 0.3% formic acid in acetonitrile and 5mM ammonium formate pH 3. The mass spectrometer was operated in positive ion mode, using multiple reaction monitoring via positive electrospray ionization. The method was linear from the limit of quantification (0.05-1 ng/mg hair and 5-25 ng/g meconium depending on analyte under investigation;) to 10 ng/mg hair and 1000 ng/g meconium, with an intra- and inter-assay imprecision and inaccuracy always less than 20% and an analytical recovery between 66.6% and 95.3%, depending on the considered analyte and biological matrix. Using the validated method, 7 mothers were found positive to one or more hair segments and 5 meconium samples were found positive to one or more antidepressant and anxiolytic drugs, assessing prenatal exposure to these drugs following maternal consumption in one or more pregnancy trimesters. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Extraction chromatographic separation of iron from complex liquid samples and the determination of 55Fe

    International Nuclear Information System (INIS)

    Grahek, Z.; Rozmaric Macefat, M.

    2006-01-01

    Iron separation is described from liquid samples with a high concentration of ions that enables simple determination of 55 Fe. One of the described methods consists of iron precipitation from a large volume seawater by sodium hydroxide and/or ammonium carbonate and separation from other elements (Ca, Sr, Cu, Mg, etc.) on a TRU column with 4M HCl or 8M HNO 3 . In the other procedure iron is separated directly from a mixture of seawater samples and HCl on a TRU column. In both methods, the iron recovery is almost 100%. After separation, 55 Fe is determined by counting with a liquid scintillation counter. The binding of Fe and Zn on TEVA, U/TEVA and TRU resins from seawater solutions of HCl and HNO 3 depends on the type of the resin, concentration of acid and other ions. Iron and zinc can be separated from seawater on a U/TEVA column with 2M HCl. (author)

  4. Gas--liquid chromatographic determination of total inorganic iodine in milk

    International Nuclear Information System (INIS)

    Bakker, H.J.

    1977-01-01

    Total inorganic iodine in milk is determined by conversion to iodobutanone, which is quantitated by gas-liquid chromatography and electron capture detection. As little as 10 μg/L can be determined. The thyroid-active iodine content of milk can be determined rapidly with a relative standard deviation of 1.9%. Average recoveries for added iodide and iodine were 95.5 and 94.6%, respectively

  5. High performance liquid chromatographic determination of Ginseng saponin by ultraviolet derivatisation

    International Nuclear Information System (INIS)

    Besso, H.; Saruwatari, Y.; Futamura, K.; Kunihiro, K.; Fuwa, T.; Tanaka, O.

    1979-01-01

    Ginsenoides Rb 1 , b 2 , c, d, e and g 1 quantitatively reacted with benzoyl chloride in pyridine to afford the respective derivatives having strong UV absorption. The UV-derivatized saponins were separated by high performance liquid chromatography (HPLC), and the saponin-contents of the various Ginseng varieties were determined. It is possible to distinguish white Ginseng from the root hairs of Ginseng by the pattern analysis of HPLC. (orig.) [de

  6. High-performance liquid chromatographic method for the determination of dansyl-polyamines

    Science.gov (United States)

    Subhash C. Minocha; Rakesh Minocha; Cheryl A. Robie

    1990-01-01

    This paper describes a fast reliable, and a sensitive technique for the separation and quantification of dansylated polyamines by high-performance liquid chromatography. Using a small 33 x 4.6 mm I.D., 3 ?m particle size, C18 reversed-phase cartridge column and a linear gradient of acetonitrile-heptanesulfonate (10 mM, pH 3.4...

  7. New Liquid Phases for the Gas Chromatographic Separation of Strong Bases on Capillary Columns

    OpenAIRE

    Grob, K.

    2017-01-01

    The current practice of pretreating the solid support with free alkali to increase separation efficiency for basic compounds proved to be unsuitable for capillary columns. Instead of this, homogenous organic materials of high base strength are required. We found polyethylene imine (PEI) and polypropylene imine (PPI) to be very efficient as liquid phases of capillary columns for the separation of bases. The preparation of polymers is mentioned. Silanization or acetylation of the free hydroxyl ...

  8. Optimisation of pressurized liquid extraction using a multivariate chemometric approach for the determination of anticancer drugs in sludge by ultra high performance liquid chromatography-tandem mass spectrometry

    OpenAIRE

    Seira , Jordan; Claparols , Catherine; Joannis-Cassan , Claire; Albasi , Claire; Montréjaud-Vignoles , Mireille; Sablayrolles , Caroline

    2013-01-01

    International audience; The present paper describes an analytical method for the determination of 2 widely administered anticancer drugs, ifosfamide and cyclophosphamide, contained in sewage sludge. The method relies on the extraction from the solid matrix by pressurized liquid extraction, sample purification by solid-phase extraction and analysis by ultra high performance liquid chromatography coupled with tandem mass spectrometry. The different parameters affecting the extraction efficiency...

  9. Accurate determination of 3-alkyl-2-methoxypyrazines in wines by gas chromatography quadrupole time-of-flight tandem mass spectrometry following solid-phase extraction and dispersive liquid-liquid microextraction.

    Science.gov (United States)

    Fontana, Ariel; Rodríguez, Isaac; Cela, Rafael

    2017-09-15

    A new reliable method for the determination 3-alkyl-2-methoxypyrazines (MPs) in wine samples based on the sequential combination of solid-phase extraction (SPE), dispersive liquid-liquid microextraction (DLLME) and gas chromatography (GC) quadrupole time-of-flight accurate tandem mass spectrometry (QTOF-MS/MS) is presented. Primary extraction of target analytes was carried out by using a reversed-phase Oasis HLB (200mg) SPE cartridge combined with acetonitrile as elution solvent. Afterwards, the SPE extract was submitted to DLLME concentration using 0.06mL carbon tetrachloride (CCl 4 ) as extractant. Under final working conditions, sample concentration factors above 379 times and limits of quantification (LOQs) between 0.3 and 2.1ngL -1 were achieved. Moreover, the overall extraction efficiency of the method was unaffected by the particular characteristics of each wine; thus, accurate results (relative recoveries from 84 to 108% for samples spiked at concentrations from 5 to 25ngL -1 ) were obtained using matrix-matched standards, without using standard additions over every sample. Highly selective chromatographic records were achieved considering a mass window of 5mDa, centered in the quantification product ion corresponding to each compound. Twelve commercial wines, elaborated with grapes from different varieties and geographical origins, were processed with the optimized method. The 2-isobutyl-3-methoxypyrazine (IBMP) was determined at levels above the LOQs of the method in half of the samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Ultra-fast liquid chromatography with tandem mass spectrometry determination of ochratoxin A in traditional Chinese medicines based on vortex-assisted solid-liquid microextraction and aptamer-affinity column clean-up.

    Science.gov (United States)

    Yang, Xihui; Hu, Yichen; Kong, Weijun; Chu, Xianfeng; Yang, Meihua; Zhao, Ming; Ouyang, Zhen

    2014-11-01

    A rapid, selective, and sensitive ultra-fast liquid chromatography with tandem mass spectrometry method was developed for the determination of ochratoxin A in traditional Chinese medicines based on vortex-assisted solid-liquid microextraction and aptamer-affinity column clean-up. Through optimizing the sample pretreatment procedures and chromatographic conditions, good linearity (r(2) ≥ 0.9993), low limit of detection (0.5-0.8 μg/kg), and satisfactory recovery (83.54-94.44%) expressed the good reliability and applicability of the established method in various traditional Chinese medicines. Moreover, the aptamer-affinity column, prepared in-house, showed an excellent feasibility owing to its specific identification of ochratoxin A in various kinds of selected traditional Chinese medicines. The maximum adsorption amount and applicability value were 188.96 ± 10.56 ng and 72.3%, respectively. The matrix effects were effectively eliminated, especially for m/z 404.2→358.0 of ochratoxin A. The application of the developed method for screening the natural contamination levels of ochratoxin A in 25 random traditional Chinese medicines on the market in China indicated that only eight samples were contaminated with low levels below the legal limit (5.0 μg/kg) set by the European Union. This study provided a preferred choice for the rapid and accurate monitoring of ochratoxin A in complex matrices. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Application of a rapid and sensitive liquid chromatography-tandem mass spectrometry method for determination of bumetanide in human plasma for a bioequivalence study.

    Science.gov (United States)

    Patel, Dinesh S; Sharma, Naveen; Patel, Mukesh C; Patel, Bhavin N; Shrivastav, Pranav S; Sanyal, Mallika

    2012-07-01

    A rapid, selective and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay has been proposed for the determination of bumetanide in human plasma using tamsulosin as internal standard (IS). The analyte and IS were extracted from 200 μL of human plasma via solid phase extraction and the chromatographic separation was achieved on Peerless Basic C18 (100 mm × 4.6 mm, 3 μm) column under isocratic conditions. Detection of bumetanide and IS was done by tandem mass spectrometry, operating in positive ionization and multiple reaction monitoring (MRM) acquisition mode. The protonated precursor to product ion transitions monitored for bumetanide and IS were m/z 365.2→240.2 and 409.2→228.2 respectively. The method was fully validated as per the US FDA guidelines. The limit of detection and lower limit of quantitation of the method were 0.03 and 0.30 ng/mL respectively with a linear dynamic range of 0.30-200.0 ng/mL for bumetanide. The intra-batch and inter-batch precision (% CV) was ≤6.9% while the mean extraction recovery was >90% across quality control levels. The method is selective in presence of four diuretic drugs and some commonly used medications by healthy volunteers. It was successfully applied to a bioequivalence study of 2mg bumetanide tablet formulation in 10 healthy Indian male subjects under fasting condition. The reproducibility in the measurement of study data was demonstrated by reanalysis of 42 incurred samples. Copyright © 2012 Elsevier B.V. All rights reserved.

  12. Liquid chromatography-tandem mass spectrometry method for the measurement of serum mevalonic acid: a novel marker of hydroxymethylglutaryl coenzyme A reductase inhibition by statins.

    Science.gov (United States)

    Waldron, Jenna; Webster, Craig

    2011-05-01

    Mevalonic acid (MVA) is synthesized at an early and rate-limiting step in the biosynthesis of cholesterol by the enzyme hydroxymethylglutaryl coenzyme A (HMG-CoA) reductase, and is a useful measure of statin efficacy or treatment. A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the measurement of serum MVA has been developed. Following the in vitro conversion of MVA to mevalonic acid lactone (MVAL) in the serum, MVAL and a deuterated internal standard were extracted using an online solid-phase extraction procedure. Chromatographic separation was achieved using a Luna PFP column (Phenomenex), with enhanced selectivity and improved resolution for polar compounds. A gradient system was used, with mobile phase comprising methanol and water (5 mmol/L ammonium formate buffer, pH 2.5). Analysis was performed using an API 5000 tandem mass spectrometer (Applied Biosystems) in positive electrospray ionization mode. The method showed excellent recoveries (98 ± 8%) and imprecision (intra-assay coefficient of variation of 2.2% [6.5 ng/mL] and 2.6% [10.5 ng/mL], and inter-assay coefficient of variation of 9% [10.5 ng/mL]). The assay provides a calibration range up to 50 ng/mL with a limit of detection at 0.1 ng/mL. A simple, rapid and analytically specific method has been developed for the measurement of serum MVA, in the form of MVAL. The high analytical sensitivity of the method allows for accurate quantitation of MVAL in serum samples, both at the endogenous levels found in healthy individuals and in statin-treated patients where normal levels are expected to be greatly reduced through the inhibition of HMG-CoA reductase.

  13. Simultaneous determination of 14 active constituents of Shengjiang Xiexin decoction using ultrafast liquid chromatography coupled with electrospray ionization tandem mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    Gang Peng; Huanyu Guan; Xiaoming Wang; Yue Shi

    2017-01-01

    An effective herbal medicinal prescription of Shengjiang Xiexin decoction (SXD) was used in treating the inflammatory bowel disease in clinic.In this study,an ultrafast liquid chromatography-tandem mass spectrometry (UFLC-MS/MS) method was developed to separate and to simultaneously determine 14 major active ingredients in SXD.Chromatographic separation was successfully accomplished on an Acquity BEH C18 (100 mm × 2.1 mm,1.7 μm) column using gradient elution with 0.1% (v/v) formic acid water (A) and 0.1% (v/v) formic acid in methanol (B).Negative and positive electrospray ionization tandem mass spectrometry was used to detect the 14 analytes using its selective reaction monitoring (SRM) mode.A good linear regression relationship for each analyte was obtained over the range from 3.88 ng/mL to 4080 ng/mL.The precision was evaluated by intra-and inter-day assays with a relative standard deviation (RSD) of less than 6.25%.The recovery measured at three concentration levels varied from 98.72% to 103.47%.The overall limits of quantification (LOQ) ranged from 2.05 ng/mL to 4.72 ng/mL.The method was successfully implemented in the qualitative and quantitative analyses of the 14 chemical constituents in SXD.The results showed that the developed UFLC-MS/MS method was linear and accurate.The method could be used reliably as a quality control method for SXD.

  14. Simultaneous determination of 14 active constituents of Shengjiang Xiexin decoction using ultrafast liquid chromatography coupled with electrospray ionization tandem mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    Gang Peng; Huanyu Guan; Xiaoming Wang; Yue Shi

    2017-01-01

    An effective herbal medicinal prescription of Shengjiang Xiexin decoction(SXD) was used in treating the inflammatory bowel disease in clinic.In this study,an ultrafast liquid chromatography-tandem mass spectrometry(UFLC-MS/MS) method was developed to separate and to simultaneously determine14 major active ingredients in SXD.Chromatographic separation was successfully accomplished on an Acquity BEH C18(100 mm × 2.1 mm,1.7 μm) column using gradient elution with 0.1%(v/v) formic acid water(A) and 0.1%(v/v) formic acid in methanol(B).Negative and positive electrospray ionization tandem mass spectrometry was used to detect the 14 analytes using its selective reaction monitoring(SRM) mode.A good linear regression relationship for each analyte was obtained over the range from3.88 ng/mL to 4080 ng/mL.The precision was evaluated by intra-and inter-day assays with a relative standard deviation(RSD) of less than 6.25%.The recovery measured at three concentration levels varied from 98.72%to 103.47%.The overall limits of quantification(LOQ) ranged from 2.05 ng/mL to4.72 ng/mL.The method was successfully implemented in the qualitative and quantitative analyses of the14 chemical constituents in SXD.The results showed that the developed UFLC-MS/MS method was linear and accurate.The method could be used reliably as a quality control method for SXD.

  15. Quantitation of donepezil and its active metabolite 6-O-desmethyl donepezil in human plasma by a selective and sensitive liquid chromatography-tandem mass spectrometric method

    Energy Technology Data Exchange (ETDEWEB)

    Patel, Bhavin N. [Chemistry Department, School of Sciences, Gujarat University, Navrangpura, Ahmedabad 380 009, Gujarat (India); Analytical Laboratory, BA Research India Ltd., Bodakdev, Ahmedabad 380 054, Gujarat (India); Sharma, Naveen [Analytical Laboratory, BA Research India Ltd., Bodakdev, Ahmedabad 380 054, Gujarat (India); Sanyal, Mallika [Chemistry Department, St. Xaviers' College, Navrangpura, Ahmedabad 380 009, Gujarat (India); Shrivastav, Pranav S. [Chemistry Department, School of Sciences, Gujarat University, Navrangpura, Ahmedabad 380 009, Gujarat (India)], E-mail: pranav_shrivastav@yahoo.com

    2008-11-23

    A sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay for the simultaneous determination of donepezil (D) and its pharmacologically active metabolite, 6-O-desmethyl donepezil (6-ODD) in human plasma is developed using galantamine as internal standard (IS). The analytes and IS were extracted from 500 {mu}L aliquots of human plasma via solid-phase extraction (SPE) on Waters Oasis HLB cartridges. Chromatographic separation was achieved in a run time of 6.0 min on a Waters Novapak C18 (150 mm x 3.9 mm, 4 {mu}m) column under isocratic conditions. Detection of analytes and IS was done by tandem mass spectrometry, operating in positive ion and multiple reaction monitoring (MRM) acquisition mode. The protonated precursor to product ion transitions monitored for D, 6-ODD and IS were at m/z 380.1 {yields} 91.2, 366.3 {yields} 91.3 and 288.2 {yields} 213.2, respectively. The method was fully validated for its selectivity, interference check, sensitivity, linearity, precision and accuracy, recovery, matrix effect, ion suppression/enhancement, cross-specificity, stability and dilution integrity. A linear dynamic range of 0.10-50.0 ng mL{sup -1} for D and 0.02-10.0 ng mL{sup -1} for 6-ODD was evaluated with mean correlation coefficient (r) of 0.9975 and 0.9985, respectively. The intra-batch and inter-batch precision (%CV, coefficient of variation) across five quality control levels was less than 7.5% for both the analytes. The method was successfully applied to a bioequivalence study of 10 mg donepezil tablet formulation in 24 healthy Indian male subjects under fasting condition.

  16. Chromatographic separations of stereoisomers

    Energy Technology Data Exchange (ETDEWEB)

    Souter, R.W.

    1985-01-01

    This text covers both diastereomers and enantiomers; describes techniques for GC, HPLC, and other chromatographic methods; and tabulates results of various applications by both techniques and compound class. It provides current knowledge about separation mechanisms and interactions of asymmetric molecules, as well as experimental and commercial materials such as columns, instruments, and derivatization reagents. The contents also include stereoisomer separations by gas chromatography. Stereoisomer separations by high-performance liquid chromatography. Stereoisomer separations by other chromatographic techniques.

  17. Correlation of liquid chromatographic and biological assay for potency assessment of filgrastim and related impurities.

    Science.gov (United States)

    Skrlin, Ana; Kosor Krnic, Ela; Gosak, Darko; Prester, Berislav; Mrsa, Vladimir; Vuletic, Marko; Runac, Domagoj

    2010-11-02

    In vivo and in vitro potency assays have always been a critical tool for confirmation of protein activity. However, due to their complexity and time consuming procedures, it remains a challenge to find an alternative analytical approach that would enable their replacement with no impact on the quality of provided information. The goal of this research was to determine if a correlation between liquid chromatography assays and in vitro biological assay could be established for filgrastim (recombinant human granulocyte-colony stimulating factor, rhG-CSF) samples containing various amounts of related impurities. For that purpose, relevant filgrastim related impurities were purified to homogeneity and characterized by liquid chromatography and mass spectrometry. A significant correlation (R(2)>0.90) between the two types of assays was revealed. Potency of oxidized filgrastim was determined to be approximately 25% of filgrastim stated potency (1 x 10(8)IU/mg of protein). Formyl-methionine filgrastim had potency of 89% of the filgrastim stated potency, while filgrastim dimer had 67% of filgrastim stated potency. A mathematical model for the estimation of biological activity of filgrastim samples from chromatography data was established and a significant correlation between experimental potency values and potency values estimated by the mathematical model was obtained (R(2)=0.92). Based on these results a conclusion was made that reversed phase high performance liquid chromatography could be used as an alternative for the in vitro biological assay for potency assessment of filgrastim samples. Such an alternative model would enable substitution of a complex and time consuming biological assay with a robust and precise instrumental method in many practical cases. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  18. Determination of benzimidazoles in meat samples by capillary zone electrophoresis tandem mass spectrometry following dispersive liquid-liquid microextraction.

    Science.gov (United States)

    Tejada-Casado, Carmen; Moreno-González, David; Lara, Francisco J; García-Campaña, Ana M; Del Olmo-Iruela, Monsalud

    2017-03-24

    A novel method based on capillary zone electrophoresis-tandem mass spectrometry has been proposed and validated for the identification and simultaneous quantification of twelve benzimidazoles in meat samples. Electrophoretic separation was carried out using 500mM formic acid (pH 2.2) as background electrolyte and applying a voltage of 25kV at 25°C. In order to improve the sensitivity, stacking mode injection was applied, using as injection solvent a mixture of 30:70 acetonitrile/water at 50mbar for 75s. Sensitivity enhancement factors from 74 to 317 were obtained under these conditions. Detection using an ion trap as analyzer, operating in multiple reactions monitoring mode was employed. The main MS/MS parameters as well as the composition of the sheath liquid and other electrospray variables were optimized in order to obtain the highest sensitivity and precision in conjunction with an unequivocal identification. The method was applied to poultry and pork muscle samples. The deproteinization of samples and extraction of benzimidazoles was carried out with acetonitrile. MgSO 4 and NaCl were added as salting-out agents. Subsequently, dispersive liquid-liquid microextraction was applied as clean up procedure. The organic layer (acetonitrile, used as dispersant) containing the benzimidazoles was mixed with the extractant (chloroform) and both were injected in water, producing a cloudy solution. Recoveries for fortified samples were higher than 70%, with relative standard deviations lower than 16% were obtained in all cases. The limits of detection were below 3μgkg -1 , demonstrating the applicability of this fast, simple, and environmentally friendly method. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. [Rapid determination of 8 urinary carbamate pesticides by liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Liu, Hualiang; Wang, Yuan; Zhu, Baoli

    2015-11-01

    To establish a method for simultaneously determining the urinary concentrations of 8 carbamate pesticides. After being purified by acetonitrile precipitation, urine samples were transferred to a liquid chromatography-tandem mass spectrometry system, and the concentrations of 8 carbamate pesticides were determined by external standard method. A C18 column was used for ultra-high-performance liquid chromatography; methanol/ammonium acetate solution was used as the mobile phase for gradient elution; the mass spectrometer was operated in a multi-reaction monitoring mode. The calibration curves were linear when the urinary concentrations of these carbamate pesticides were 20~800 µg/L, and the recovery rates were 61.0%~121% at spiked levels of 20, 200 and 800 µg/L, with a relative standard deviation of 1.7%~5.5%. This determination method meets the Guide for establishing occupational health standards-part 5: Determination methods of chemicals in biological materials, and can be used for simultaneous determination of 8 carbamate pesticides in the urine of poisoning patients.

  20. Targeted liquid chromatography tandem mass spectrometry to quantitate wheat gluten using well-defined reference proteins

    Science.gov (United States)

    Schalk, Kathrin; Koehler, Peter

    2018-01-01

    Celiac disease (CD) is an inflammatory disorder of the upper small intestine caused by the ingestion of storage proteins (prolamins and glutelins) from wheat, barley, rye, and, in rare cases, oats. CD patients need to follow a gluten-free diet by consuming gluten-free products with gluten contents of less than 20 mg/kg. Currently, the recommended method for the quantitative determination of gluten is an enzyme-linked immunosorbent assay (ELISA) based on the R5 monoclonal antibody. Because the R5 ELISA mostly detects the prolamin fraction of gluten, a new independent method is required to detect prolamins as well as glutelins. This paper presents the development of a method to quantitate 16 wheat marker peptides derived from all wheat gluten protein types by liquid chromatography tandem mass spectrometry (LC-MS/MS) in the multiple reaction monitoring mode. The quantitation of each marker peptide in the chymotryptic digest of a defined amount of the respective reference wheat protein type resulted in peptide-specific yields. This enabled the conversion of peptide into protein type concentrations. Gluten contents were expressed as sum of all determined protein type concentrations. This new method was applied to quantitate gluten in wheat starches and compared to R5 ELISA and gel-permeation high-performance liquid chromatography with fluorescence detection (GP-HPLC-FLD), which resulted in a strong correlation between LC-MS/MS and the other two methods. PMID:29425234

  1. Targeted liquid chromatography tandem mass spectrometry to quantitate wheat gluten using well-defined reference proteins.

    Directory of Open Access Journals (Sweden)

    Kathrin Schalk

    Full Text Available Celiac disease (CD is an inflammatory disorder of the upper small intestine caused by the ingestion of storage proteins (prolamins and glutelins from wheat, barley, rye, and, in rare cases, oats. CD patients need to follow a gluten-free diet by consuming gluten-free products with gluten contents of less than 20 mg/kg. Currently, the recommended method for the quantitative determination of gluten is an enzyme-linked immunosorbent assay (ELISA based on the R5 monoclonal antibody. Because the R5 ELISA mostly detects the prolamin fraction of gluten, a new independent method is required to detect prolamins as well as glutelins. This paper presents the development of a method to quantitate 16 wheat marker peptides derived from all wheat gluten protein types by liquid chromatography tandem mass spectrometry (LC-MS/MS in the multiple reaction monitoring mode. The quantitation of each marker peptide in the chymotryptic digest of a defined amount of the respective reference wheat protein type resulted in peptide-specific yields. This enabled the conversion of peptide into protein type concentrations. Gluten contents were expressed as sum of all determined protein type concentrations. This new method was applied to quantitate gluten in wheat starches and compared to R5 ELISA and gel-permeation high-performance liquid chromatography with fluorescence detection (GP-HPLC-FLD, which resulted in a strong correlation between LC-MS/MS and the other two methods.

  2. [Determination of phthalate plasticizers in foods by high performance liquid chromatography with gel permeation chromatographic clean-up].

    Science.gov (United States)

    Zhang, Chunyu; Wang, Hui; Zhang, Xiaohui; Ma, Zhongqiang; Deng, Wanmei; Hu, Ke; Ding, Mingyu

    2011-12-01

    A method of gel permeation chromatography-high performance liquid chromatography (GPC-HPLC) was established for the simultaneous determination of 5 main phthalate plasticizers in foods (edible oil, instant noodles, fried pastries, Saqima, etc.). The samples were extracted with petroleum ether in an ultrasonator, purified by a GPC column, and analyzed by HPLC. The chromatographic separation was achieved on a Labtech-C18 column (250 mm x 4.6 mm, 5 microm) using acetonitrile and water mixture as the mobile phases in a gradient elution mode. The developed method exhibited a linear correlation coefficient of more than 0.997 and the detection limits of 3.25 - 13.4 microg/L. The spike recoveries were between 70.4% and 113.6% with the relative standard deviations (RSDs, n = 3) of 0.3% - 5.8% at the spiked level of 50 mg/L. This method is simple, rapid and practical, and can be used for the simultaneous determination of PAEs in grease food samples.

  3. Post-synthetic modification of MIL-101(Cr) with pyridine for high-performance liquid chromatographic separation of tocopherols.

    Science.gov (United States)

    Yang, Fang; Yang, Cheng-Xiong; Yan, Xiu-Ping

    2015-05-01

    Effective separation of tocopherols is challenging and significant due to their structural similarity and important biological role. Here we report the post-synthetic modification of metal-organic framework (MOF) MIL-101(Cr) with pyridine for high-performance liquid chromatographic (HPLC) separation of tocopherols. Baseline separation of four tocopherols was achieved on a pyridine-grafted MIL-101(Cr) packed column within 10 min using hexane/isopropanol (96:4, v/v) as the mobile phase at a flow rate of 0.5 mL min(-1). The pyridine-grafted MIL-101(Cr) packed column gave high column efficiency (85,000 plates m(-1) for δ-tocopherol) and good precision (0.2-0.3% for retention time, 1.8-3.4% for peak area, 2.6-2.7% for peak height), and also offered much better performance than unmodified MIL-101(Cr) and commercial amino-bonded silica packed column for HPLC separation of tocopherols. The results not only show the promising application of pyridine-grafted MIL-101(Cr) as a novel stationary phase for HPLC separation of tocopherols, but also reveal a facile post-modification of MOFs to expand the application of MOFs in separation sciences. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Ultra-performance liquid chromatographic determination of L-ergothioneine in commercially available classes of cow milk.

    Science.gov (United States)

    Sotgia, Salvatore; Pisanu, Elisabetta; Cambedda, Debora; Pintus, Gianfranco; Carru, Ciriaco; Zinellu, Angelo

    2014-09-01

    A new efficient and sensitive precolumn hydrophilic interaction ultra-performance liquid chromatography (HILIC-UPLC) method was established for the quantitative determination of L-ergothioneine (ERT) in milk. After derivatization of ERT with 7-diethylamino-3-[4-(iodoacetamido)phenyl]-4-methylcoumarin, chromatographic separation was achieved in a fairly short time, less than 5 min, on a 100 × 2.1 mm Waters Cortecs UPLC HILIC 1.6-μm column, by using a mixture of 30 mmol/L ammonium acetate/acetonitrile (10:90, v/v) as a mobile phase flowing isocratically at 0.9 mL/min. Limit of detection and the limit of quantification were 0.03 and 0.10 μmol/L, respectively. The method exhibited linearity in a concentration range of 0.16 and 5.08 μmol/L. Mean recovery was 106.66%, whereas intra- and interassay precisions were determined to be within 6 RSD%. On average, ERT concentration in different commercially available classes of cow milk was found to be 0.442 ± 0.191 μmol/L, with the highest levels in the ultra-high temperature milks and low values in the unprocessed and HTST whole milks. In this light, our experiments suggest that ERT could be used as a marker for the heat treatment of milk. © 2014 Institute of Food Technologists®

  5. Reversed-phase liquid chromatographic profile of free amino acids in strawberry-tree (Arbutus unedo L.) honey.

    Science.gov (United States)

    Spano, Nadia; Piras, Irene; Ciulu, Marco; Floris, Ignazio; Panzanelli, Angelo; Pilo, Maria I; Piu, Paola C; Sanna, Gavino

    2009-01-01

    The typical profile of the free amino acids contained in strawberry-tree (Arbutus unedo L.) honey is reported for the first time. An optimized reversed-phase liquid chromatographic (RP-LC) method with phenyl isothiocyanate precolumn derivatization was used. Fourteen free amino acids were identified and quantified in 16 analytical samples. Proline (65.63%) was found to be the most abundant free amino acid, followed by glutamic acid (6.49%), arginine (5.21%), alanine (5.17%), and phenylalanine (4.97%). The total free amino acid content of strawberry-tree honey (average value, 436 mg/kg) was found to be low in comparison to amounts cited in the literature concerning unifloral honeys. The analytical method was optimized and fully validated in terms of detection and quantitation limits, precision (by testing repeatability and reproducibility), linearity, and bias (by means of recovery tests). The acceptability of the validation protocol results was verified using Horwitz's mathematical model and AOAC guidelines.

  6. Application of Analytical Quality by Design concept for bilastine and its degradation impurities determination by hydrophilic interaction liquid chromatographic method.

    Science.gov (United States)

    Terzić, Jelena; Popović, Igor; Stajić, Ana; Tumpa, Anja; Jančić-Stojanović, Biljana

    2016-06-05

    This paper deals with the development of hydrophilic interaction liquid chromatographic (HILIC) method for the analysis of bilastine and its degradation impurities following Analytical Quality by Design approach. It is the first time that the method for bilastine and its impurities is proposed. The main objective was to identify the conditions where an adequate separation in minimal analysis duration could be achieved within a robust region. Critical process parameters which have the most influence on method performance were defined as acetonitrile content in the mobile phase, pH of the aqueous phase and ammonium acetate concentration in the aqueous phase. Box-Behnken design was applied for establishing a relationship between critical process parameters and critical quality attributes. The defined mathematical models and Monte Carlo simulations were used to identify the design space. Fractional factorial design was applied for experimental robustness testing and the method is validated to verify the adequacy of selected optimal conditions: the analytical column Luna(®) HILIC (100mm×4.6mm, 5μm particle size); mobile phase consisted of acetonitrile-aqueous phase (50mM ammonium acetate, pH adjusted to 5.3 with glacial acetic acid) (90.5:9.5, v/v); column temperature 30°C, mobile phase flow rate 1mLmin(-1), wavelength of detection 275nm. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Forensic Analysis of Blue Ball point Pen Inks Using Ultraviolet-Visible Spectrometer and Ultra-Performance Liquid Chromatograph

    International Nuclear Information System (INIS)

    Lee, L.C.; Shandu, K.T.S.; Nor Syahirah Mohamad Razi; Ab Aziz Ishak; Khairul Osman

    2015-01-01

    Twelve varieties of blue ball point pens were selected and analyzed using UV-Vis spectrometer and ultra-performance liquid chromatography (UPLC). The aim of the study was to determine discrimination power (DP) of these methods in differentiating pen inks collected from the market in Malaysia. Discrimination analysis of 66 possible pen-pair of blue ball point pens was carried out via one-way ANOVA based on obtained chromatogram and spectra. A total of 18 peaks were determined as coming from inks based on the chromatographic data extracted at three different wavelengths (279, 370 and 400 nm). While for the UV-Vis spectrometer analysis, presence of peaks at 303, 545, 577 and 584 nm wavelengths were recorded. UV-Vis spectral data were mainly produced by the colorant components (for example, dyes) found in inks and UPLC may detect ink components other than dyes, for example, additives. As conclusion, the DP for UV-Vis and UPLC were determined to be 72.12 % and 98.48 %, respectively. This manuscript demonstrates the potential of UPLC for discriminating pen inks based on non-dye components. Additionally, the dye components in inks do not seem to play important role in discrimination of pen inks. (author)

  8. Stability-indicating liquid chromatographic method for quantification of new anti-epileptic drug lacosamide in bulk and pharmaceutical formulation

    Directory of Open Access Journals (Sweden)

    Chhalotiya Usmangani K.

    2012-01-01

    Full Text Available An isocratic stability indicating reversed-phase liquid chromatographic determination was developed for the quantitative determination of lacosamide in the pharmaceutical dosage form. A Hypersil C-18, 4.5μm column with mobile phase containing acetonitrile-water (20:80, v/v was used. The flow rate was 1.0 mL min-1 and effluents were monitored at 258 nm. The retention time of lacosamide was 8.9 min. The method was found to be linear in the concentration range of 5-100 μg/ml and the recovery was found to be in the range of 99.15 - 100.09 %. The limit of detection and limit of quantification were found to be 2 μg/ml and 5 μg/ml, respectively. Lacosamide stock solutions were subjected to acid and alkali hydrolysis, chemical oxidation and dry heat degradation. The drug was found to be stable to the dry heat and acidic condition attempted. The proposed method was validated and successfully applied to the estimation of lacosamide in tablet dosage forms.

  9. Development and validation of a reversed phase liquid chromatographic method for analysis of oxytetracycline and related impurities.

    Science.gov (United States)

    Kahsay, Getu; Shraim, Fairouz; Villatte, Philippe; Rotger, Jacques; Cassus-Coussère, Céline; Van Schepdael, Ann; Hoogmartens, Jos; Adams, Erwin

    2013-03-05

    A simple, robust and fast high-performance liquid chromatographic method is described for the analysis of oxytetracycline and its related impurities. The principal peak and impurities are all baseline separated in 20 min using an Inertsil C₈ (150 mm × 4.6 mm, 5 μm) column kept at 50 °C. The mobile phase consists of a gradient mixture of mobile phases A (0.05% trifluoroacetic acid in water) and B (acetonitrile-methanol-tetrahydrofuran, 80:15:5, v/v/v) pumped at a flow rate of 1.3 ml/min. UV detection was performed at 254 nm. The developed method was validated for its robustness, sensitivity, precision and linearity in the range from limit of quantification (LOQ) to 120%. The limits of detection (LOD) and LOQ were found to be 0.08 μg/ml and 0.32 μg/ml, respectively. This method allows the separation of oxytetracycline from all known and 5 unknown impurities, which is better than previously reported in the literature. Moreover, the simple mobile phase composition devoid of non-volatile buffers made the method suitable to interface with mass spectrometry for further characterization of unknown impurities. The developed method has been applied for determination of related substances in oxytetracycline bulk samples available from four manufacturers. The validation results demonstrate that the method is reliable for quantification of oxytetracycline and its impurities. Copyright © 2012 Elsevier B.V. All rights reserved.

  10. High-performance liquid chromatographic assay for two rifamycin-derived hypocholesterolemic agents in liver and biological fluids.

    Science.gov (United States)

    Moore, D J; Perrino, P J; Klerer, C P; Robertson, P

    1993-02-26

    CGP 43371 (compound I), a mono-pivaloyl oxazole derivative of a 3-piperazino-rifamycin, has been in clinical trials as a potential hypocholesterolemic agent. A reversed-phase high-performance liquid chromatographic (HPLC) assay was developed using a C18 column and a gradient solvent system of methanol-0.1 M sodium acetate, pH 4.5, at a flow-rate of 1 ml/min. The compound and internal standard (rifampicin) were detected by their ultraviolet absorption at 254 nm. Isolation of the compounds from plasma and liver homogenates was accomplished by precipitation of proteins with acetonitrile, followed by evaporation under nitrogen and reconstitution in methanol. Bile, lymph and urine were injected onto the HPLC column without pretreatment. Calibration curves were linear (r > 0.999) over the concentration range 0.25-20.0 micrograms/ml. The assay procedure was also applicable to other rifamycin derivatives and was able to distinguish between molecular species containing small differences in functionality.

  11. Multivariate curve-resolution analysis of pesticides in water samples from liquid chromatographic-diode array data.

    Science.gov (United States)

    Maggio, Rubén M; Damiani, Patricia C; Olivieri, Alejandro C

    2011-01-30

    Liquid chromatographic-diode array detection data recorded for aqueous mixtures of 11 pesticides show the combined presence of strongly coeluting peaks, distortions in the time dimension between experimental runs, and the presence of potential interferents not modeled by the calibration phase in certain test samples. Due to the complexity of these phenomena, data were processed by a second-order multivariate algorithm based on multivariate curve resolution and alternating least-squares, which allows one to successfully model both the spectral and retention time behavior for all sample constituents. This led to the accurate quantitation of all analytes in a set of validation samples: aldicarb sulfoxide, oxamyl, aldicarb sulfone, methomyl, 3-hydroxy-carbofuran, aldicarb, propoxur, carbofuran, carbaryl, 1-naphthol and methiocarb. Limits of detection in the range 0.1-2 μg mL(-1) were obtained. Additionally, the second-order advantage for several analytes was achieved in samples containing several uncalibrated interferences. The limits of detection for all analytes were decreased by solid phase pre-concentration to values compatible to those officially recommended, i.e., in the order of 5 ng mL(-1). Copyright © 2010 Elsevier B.V. All rights reserved.

  12. Liquid chromatographic determination of chloramine-T and its primary degradation product, p-toluenesulfonamide, in water

    Science.gov (United States)

    Dawson, Verdel K.; Davis, Ruth A.

    1997-01-01

    N-sodium-N-chloro-rho-toluenesulfonamide (chloramine-T) effectively controls bacterial gill disease (BGD) in cultured fishes, BGD, a common disease of hatchery-reared salmonids, causes more fish losses than any other disease among these species. This study describes a liquid chromatographic (LC) method that is capable of direct, simultaneous analysis of chloramine-T and its primary degradation product, rho-toluenesulfonamide (rho-TSA), in water. The procedure involves reversed-phase (C-18) LC analysis with ion suppression, using 0.01 M phosphate buffer at pH 3. The mobile phase is phosphate buffer-acetonitrile (60 + 40) at 1 mL/min. Both chemicals can be detected with a UV spectrophotometer at 229 nm; the method is linear up to 40 mg, chloramine-T or rho-TSA/L. Mean recoveries were 96.4 +/- 6.1% for water samples fortified with 0.03 mg chloramine-T/L and 95.3 +/- 4.6% for water samples fortified with 0.005 mg rho-TSA/L. Limits of detection without sample enrichment for chloramine-T and rho-TSA are 0.01 mg/L and 0.001 mg/L, respectively.

  13. An improved high-performance liquid chromatographic method for simultaneous determination of tocopherols, tocotrienols and γ-oryzanol in rice.

    Science.gov (United States)

    Huang, Shao-Hua; Ng, Lean-Teik

    2011-07-22

    An improved normal phase high performance liquid chromatographic (NP-HPLC) method was developed for simultaneous quantification of eight vitamin E isomers (α-, β-, γ- and δ-tocopherols and α-, β-, γ- and δ-tocotrienols) and γ-oryzanol in rice. A complete separation of all compounds was achieved within 25 min using an Inertsil CN-3, SIL-100A 5 μM (4.6 mm × 250 mm) column and an isocratic elution system of hexane/isopropanol/ethylacetate/acetic acid (97.6:0.8:0.8:0.8, v/v/v/v) at a flow rate varying from 0.7 to 1.5 mL min(-1). A linear correlation coefficient (r(2)>0.99) and high reproducibility were obtained at concentrations ranging 0.05-10 μg mL(-1) for vitamin E isomers and 0.5-500 μg mL(-1) for γ-oryzanol. This method proved to be rapid, accurate and reproducible. Copyright © 2011 Elsevier B.V. All rights reserved.

  14. Precolumn derivatization followed by liquid chromatographic separation and determination of tramiprosate in rat plasma by fluorescence detector: application to pharmacokinetics.

    Science.gov (United States)

    Rao, R Nageswara; Maurya, Pawan K; Shinde, Dhananjay D; Khalid, Sara

    2011-05-15

    Alzheimer disease (AD) is characterized pathologically by extracellular amyloid deposits composed of amyloid β (Aβ) protein. A simple and rapid method using HPLC with fluorescence detector was developed and validated for determination of tramiprosate in rat plasma. Pre-column derivatization of the deproteinized rat plasma was carried out using o-phthaldialdehyde (OPA) as a fluorescent reagent in presence of 3-mercaptopropionic acid. The liquid chromatographic separation was achieved on a Kromasil C18 column using methanol:acetonitrile: 20 mM phosphate buffer pH 7.5 (8.0:17.5:74.5 v/v/v) as a mobile phase in an isocratic elution mode. The eluents were monitored by a fluorescence detector set at 330 and 450 nm of excitation and emission wavelength respectively. Vigabatrin was used as an internal standard. The method was linear within the range 30.0-1000.0 ng/mL. Design of experiments (DOE) was used to evaluate the robustness of the method. The developed method was applied to study the pharmacokinetics of tramiprosate in rats. Copyright © 2011. Published by Elsevier B.V.

  15. Radioimmunoassay and liquid-chromatographic analysis for free cortisol in urine compared with isotope dilution-mass spectrometry

    International Nuclear Information System (INIS)

    Lantto, O.

    1982-01-01

    Three different routine methods for analysis for urinary cortisol with those by a highly specific reference method based on isotope dilution-mass spectrometry (I) were compared. A ''high-performance'' liquid-chromatographic method (II) gave the most comparable results (regression coefficient 0.86, intercept 9 nmol/L). For some urines much lower values were obtained by I than by II. Two radioimmunoassay (III) methods, one involving direct assay and one involving extraction, gave less-accurate results (regression coefficients of 1.87 and 1.52 and intercepts of 86 and 12 nmol/L, respectively), although values obtained by III and by I correlated well (r = 0.95-0.99), indicating a relation between the free cortisol and the compounds interfering in III. The apparent accuracy for the extraction method was improved by using as calibration standards urine samples previously assayed by I (regression coefficient 0.90, intercept 6 nmol/L). All four methods investigated showed a statistically significant sex-related difference in 24-h urinary cortisol excretion; evidently such a finding should be a prerequisite in any such method proposed for routine use

  16. Gas-liquid chromatographic determination of aniline metabolites of substituted urea and carbamate herbicides in aqueous solution.

    Science.gov (United States)

    Hargesheimer, E E; Coutts, R T; Pasutto, F M

    1981-07-01

    A simple gas-liquid chromatographic (GLC) method has been developed which provides sensitivity and specificity for the analysis of complex mixtures of the commonly occurring herbicide metabolites aniline, 3-chloroaniline, 4-chloroaniline, 4-bromoaniline, and 3-chloro-4-methylaniline. All of these anilines react with acetic anhydride directly in basified aqueous solution. Further reaction of the acetylated anilines with trifluoroacetic anhydride gave diacyl derivatives which were readily resolved by gas chromatography. The structures of the N-acetylated and N-trifluoroacetylated derivatives of benzylamine (internal standard) and the anilines were confirmed by GLC-mass spectrometry. In distilled water the minimum detectable concentrations of aniline and the substituted anilines, using electron capture GLC, are 0.1 nmole/100 mL and 0.05 nmole/100 mL, respectively. The detection limit for the anilines is 1 nmole/100 mL distilled water, using GLC with flame ionization detection. The technique was applied to the determination of anilines added to urine samples obtained from the general population.

  17. Rapid ion-pair liquid chromatographic method for the determination of fenbendazole marker residue in fermented dairy products.

    Science.gov (United States)

    Vousdouka, Venetia I; Papapanagiotou, Elias P; Angelidis, Apostolos S; Fletouris, Dimitrios J

    2017-04-15

    A simple, rapid and sensitive liquid chromatographic method that allows for the quantitative determination of fenbendazole residues in fermented dairy products is described. Samples were extracted with a mixture of acetonitrile-phosphoric acid and the extracts were defatted with hexane to be further partitioned into ethyl acetate. The organic layer was evaporated to dryness and the residue was reconstituted in mobile phase. Separation of fenbendazole and its sulphoxide, sulphone, and p-hydroxylated metabolites was carried out isocratically with a mobile phase containing both positively and negatively charged pairing ions. Overall recoveries ranged from 79.8 to 88.8%, while precision data, based on within and between days variations, suggested an overall relative standard deviation of 6.3-11.0%. The detection and quantification limits were lower than 9 and 21μg/kg, respectively. The method has been successfully applied to quantitate fenbendazole residues in Feta cheese and yoghurt made from spiked and incurred ovine milk. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Determination of rivaroxaban in patient's plasma samples by anti-Xa chromogenic test associated to High Performance Liquid Chromatography tandem Mass Spectrometry (HPLC-MS/MS).

    Science.gov (United States)

    Derogis, Priscilla Bento Matos; Sanches, Livia Rentas; de Aranda, Valdir Fernandes; Colombini, Marjorie Paris; Mangueira, Cristóvão Luis Pitangueira; Katz, Marcelo; Faulhaber, Adriana Caschera Leme; Mendes, Claudio Ernesto Albers; Ferreira, Carlos Eduardo Dos Santos; França, Carolina Nunes; Guerra, João Carlos de Campos

    2017-01-01

    Rivaroxaban is an oral direct factor Xa inhibitor, therapeutically indicated in the treatment of thromboembolic diseases. As other new oral anticoagulants, routine monitoring of rivaroxaban is not necessary, but important in some clinical circumstances. In our study a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was validated to measure rivaroxaban plasmatic concentration. Our method used a simple sample preparation, protein precipitation, and a fast chromatographic run. It was developed a precise and accurate method, with a linear range from 2 to 500 ng/mL, and a lower limit of quantification of 4 pg on column. The new method was compared to a reference method (anti-factor Xa activity) and both presented a good correlation (r = 0.98, p plasma samples for rivaroxaban measurement by HPLC-MS/MS without interferences. The chromogenic and HPLC-MS/MS methods were highly correlated and should be used as clinical tools for drug monitoring. The method was applied successfully in a group of 49 real-life patients, which allowed an accurate determination of rivaroxaban in peak and trough levels.

  19. Metabolism of Genipin in Rat and Identification of Metabolites by Using Ultraperformance Liquid Chromatography/Quadrupole Time-of-Flight Tandem Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Yue Ding

    2013-01-01

    Full Text Available The in vivo and in vitro metabolism of genipin was systematically investigated in the present study. Urine, plasma, feces, and bile were collected from rats after oral administration of genipin at a dose of 50 mg/kg body weight. A rapid and sensitive method using ultraperformance liquid chromatography coupled with electrospray ionization quadrupole time-of-flight tandem mass spectrometry (UPLC-Q/TOF MS was developed for analysis of metabolic profile of genipin in rat biological samples (urine, plasma, feces, and bile. A total of ten metabolites were detected and identified by comparing their fragmentation patterns with that of genipin using MetaboLynx software tools. On the basis of the chromatographic peak area, the sulfated and glucuronidated conjugates of genipin were identified as major metabolites. And the existence of major metabolites G1 and G2 was confirmed by the in vitro enzymatic study further. Then, metabolite G1 was isolated from rat bile by semipreparative HPLC. Its structure was unambiguously identified as genipin-1-o-glucuronic acid by comparison of its UV, IR, ESI-MS, 1H-NMR, and 13C-NMR spectra with conference. In general, genipin was a very active compound that would transform immediately, and the parent form of genipin could not be observed in rats biological samples. The biotransformation pathways of genipin involved demethylated, ring-opened, cysteine-conjugated, hydroformylated, glucuronidated, and sulfated transformations.

  20. Determination of isoorientin levels in rat plasma after oral administration of Vaccinum bracteatum Thunb. methanol extract by high-performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Kim, Min-Ji; Kwon, Seung-Hwan; Jang, Choon-Gon; Maeng, Han-Joo

    2018-01-15

    A simple, sensitive and rapid liquid chromatography tandem mass spectrometry method (LC-MS/MS) was developed and validated for the determination of plasma isoorientin levels in rats. After simple protein precipitation using methanol, chromatographic analysis was performed using a Synergi 4μ polar-RP 80A column (150 × 2.0 mm, 4μm) under isocratic conditions and a mobile phase consisting of 0.1% formic acid in water and methanol (80:20, v/v) at a flow rate of 0.2 mL/min. In positive electrospray ionization mode, the protonated precursor and product ion transitions of isoorientin (m/z 449.0 → 299.1) and of puerarin (the internal standard; m/z 417.1 → 297.1) were acquired by multiple reaction monitoring. Calibration curves obtained for plasma showed good linearity over the concentration range 1-1000 ng/mL. The lower limit of quantification was 1 ng/mL. Intra- and inter-day precisions were within 8.8% relative standard deviation. Accuracies ranged from 92.1 and 109.7%. The isoorientin stability in rat plasma under typical handling/storage conditions also found to be acceptable. The developed method was applied successfully to a pharmacokinetic study of isoorientin orally administered as the methanol extract of Vaccinium bracteatum Thunb. or administered as pure isoorientin. Copyright © 2018 John Wiley & Sons, Ltd.

  1. Identification of phenylbutyrate-generated metabolites in Huntington disease patients using parallel liquid chromatography/electrochemical array/mass spectrometry and off-line tandem mass spectrometry.

    Science.gov (United States)

    Ebbel, Erika N; Leymarie, Nancy; Schiavo, Susan; Sharma, Swati; Gevorkian, Sona; Hersch, Steven; Matson, Wayne R; Costello, Catherine E

    2010-04-15

    Oral sodium phenylbutyrate (SPB) is currently under investigation as a histone deacetylation (HDAC) inhibitor in Huntington disease (HD). Ongoing studies indicate that symptoms related to HD genetic abnormalities decrease with SPB therapy. In a recently reported safety and tolerability study of SPB in HD, we analyzed overall chromatographic patterns from a method that employs gradient liquid chromatography with series electrochemical array, ultraviolet (UV), and fluorescence (LCECA/UV/F) for measuring SPB and its metabolite phenylacetate (PA). We found that plasma and urine from SPB-treated patients yielded individual-specific patterns of approximately 20 metabolites that may provide a means for the selection of subjects for extended trials of SPB. The structural identification of these metabolites is of critical importance because their characterization will facilitate understanding the mechanisms of drug action and possible side effects. We have now developed an iterative process with LCECA, parallel LCECA/LCMS, and high-performance tandem MS for metabolite characterization. Here we report the details of this method and its use for identification of 10 plasma and urinary metabolites in treated subjects, including indole species in urine that are not themselves metabolites of SPB. Thus, this approach contributes to understanding metabolic pathways that differ among HD patients being treated with SPB. Copyright 2010 Elsevier Inc. All rights reserved.

  2. Quantitative determination of a synthetic amide derivative of gallic acid, SG-HQ2, using liquid chromatography tandem mass spectrometry, and its pharmacokinetics in rats.

    Science.gov (United States)

    Seo, Seung-Yong; Kang, Wonku

    2016-11-30

    An amide derivative of gallic acid (GA), 3,4,5-trihydroxy-N-(8-hydroxyquinolin-2-yl)benzamide) (SG-HQ2) was recently synthesized, and its inhibitory actions were previously shown on histamine release and pro-inflammatory cytokine expression. In this study, a simultaneous quantification method was developed for the determination of SG-HQ2 and its possible metabolite, GA, in rat plasma using liquid chromatography with a tandem mass spectrometry (LC-MS/MS). After simple protein precipitation with acetonitrile including diclofenac (internal standard, IS), the analytes were chromatographed on a reversed phased column with a mobile phase of acetonitrile and water (60:40, v/v, including 0.1% formic acid). The ion transitions of the precursor to the product ion were principally protonated ion [M+H] + at m/z 313.2→160.6 for SG-HQ2, and deprotonated ions [M-H] - at m/z 168.7→124.9 for GA and 296.0→251.6 for the IS. The accuracy and precision of the assay were in accordance with FDA regulations for the validation of bioanalytical methods. This method was successfully applied to a pharmacokinetic study of SG-HQ2 after intravenous administration in rats. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Trace analysis of selected hormones and sterols in river sediments by liquid chromatography-atmospheric pressure chemical ionization-tandem mass spectrometry.

    Science.gov (United States)

    Matić, Ivana; Grujić, Svetlana; Jauković, Zorica; Laušević, Mila

    2014-10-17

    In this paper, development and optimization of new LC-MS method for determination of twenty selected hormones, human/animal and plant sterols in river sediments were described. Sediment samples were prepared using ultrasonic extraction and clean up with silica gel/anhydrous sodium sulphate cartridge. Extracts were analyzed by liquid chromatography-linear ion trap-tandem mass spectrometry, with atmospheric pressure chemical ionization. The optimized extraction parameters were extraction solvent (methanol), weight of the sediment (2 g) and time of ultrasonic extraction (3× 10 min). Successful chromatographic separation of hormones (estriol and estrone, 17α- and 17β-estradiol) and four human/animal sterols (epicoprostanol, coprostanol, α-cholestanol and β-cholestanol) that have identical fragmentation reactions was achieved. The developed and optimized method provided high recoveries (73-118%), low limits of detection (0.8-18 ng g(-1)) and quantification (2.5-60 ng g(-1)) with the RSDs generally lower than 20%. Applicability of the developed method was confirmed by analysis of six river sediment samples. A widespread occurrence of human/animal and plant sterols was found. The only detected hormone was mestranol in just one sediment sample. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Evaluation of different hydrophilic stationary phases for the simultaneous determination of iminosugars and other low molecular weight carbohydrates in vegetable extracts by liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Rodríguez-Sánchez, S; Quintanilla-López, J E; Soria, A C; Sanz, M L

    2014-11-01

    Iminosugars are considered potential drug candidates for the treatment of several diseases, mainly as a result of their α-glycosidase inhibition properties. A method by hydrophilic interaction liquid chromatography tandem mass spectrometry has been optimized for the first time for the simultaneous determination of complex mixtures of bioactive iminosugars and other low molecular weight carbohydrates (LMWC) in vegetable extracts. Three hydrophilic stationary phases (sulfoalkylbetaine zwitterionic, polyhydroxyethyl aspartamide and ethylene bridge hybrid (BEH) with trifunctionally bonded amide) were compared under both basic and acidic conditions. The best sensitivity (limits of detection between 0.025 and 0.28ngmL -1 ) and overall chromatographic performance in terms of resolution, peak width and analysis time were obtained with the BEH amide column using 0.1% ammonium hydroxide as a mobile phase additive. The optimized method was applied to the analysis of extracts of hyacinth bulbs, buckwheat seeds and mulberry leaves. Iminosugar and other LMWC structures were tentatively assigned by their high resolution daughter ions mass spectra. Several iminosugars such as glycosyl-fagomine in mulberry extract were also described for the first time. Among the extracts analysed, mulberry showed the widest diversity of iminosugars, whereas the highest content of them was found in hyacinth bulb (2.5mgg -1 ) followed by mulberry (1.95 mgg -1 ). Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Simultaneous determination of amino acids and neurotransmitters in plasma samples from schizophrenic patients by hydrophilic interaction liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Domingues, Diego Soares; Crevelin, Eduardo José; de Moraes, Luiz Alberto Beraldo; Cecilio Hallak, Jaime Eduardo; de Souza Crippa, José Alexandre; Costa Queiroz, Maria Eugênia

    2015-03-01

    A sensitive, reproducible, and rapid method was developed for the simultaneous determination of underivatized amino acids (aspartate, serine, glycine, alanine, methionine, leucine, tyrosine, and tryptophan) and neurotransmitters (glutamate and γ-aminobutyric acid) in plasma samples using hydrophilic interaction liquid chromatography coupled to triple quadrupole tandem mass spectrometry. The plasma concentrations of amino acids and neurotransmitters obtained from 35 schizophrenic patients in treatment with clozapine (27 patients) and olanzapine (eight patients) were compared with those obtained from 38 healthy volunteers to monitor the effectiveness of treatment. The chromatographic conditions separated ten target compounds within 3 min. This method presented linear ranges that varied from (lower limit of quantification: 9.7-13.3 nmol/mL) to (upper limit of quantification: 19.4-800 nmol/mL), intra- and interassay precision with coefficients of variation lower than 10%, and relative standard error values of the accuracy ranged from -2.1 to 9.9%. The proposed method appropriately determines amino acids and neurotransmitters in plasma from schizophrenic patients. Compared with the control group (healthy volunteers), the plasma levels of methionine in schizophrenic patients treated with olanzapine are statistically significantly higher. Moreover, schizophrenic patients treated with clozapine tend to have increased plasma levels of glutamate. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Simultaneous determination of tedizolid and linezolid in rat plasma by ultra performance liquid chromatography tandem mass spectrometry and its application to a pharmacokinetic study.

    Science.gov (United States)

    Yu, Hua-chen; Pan, Chen-wei; Xie, Qi-peng; Zheng, Yi; Hu, Yue-zheng; Lin, Yi-mu

    2016-02-01

    A sensitive and rapid ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method was developed to determine tedizolid and linezolid in rat plasma simultaneously. Chromatographic separation was carried out on an Acquity UPLC BEH C18 column and mass spectrometric analysis was performed using a XEVO TQD triple quadruple mass spectrometer coupled with an electrospray ionization (ESI) source in the positive ion mode. Multiple reaction monitoring (MRM) mode was used for quantification using target fragment ions m/z 371.4→343.2 for tedizolid, and m/z 338.3→56.1 for linezolid. This assay method has been fully validated in terms of selectivity, linearity, recovery and matrix effect, accuracy, precision and stability. The linearity of this method was found to be within the concentration range of 5-5000ng/mL for tedizolid, and 10-10,000ng/mL for linezolid in rat plasma, respectively. Only 3.0min was needed for an analytical run. This assay was used to support a preclinical study where multiple oral doses were administered to rats to investigate the pharmacokinetics of tedizolid and linezolid. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Characterization of metabolites of leonurine (SCM-198) in rats after oral administration by liquid chromatography/tandem mass spectrometry and NMR spectrometry.

    Science.gov (United States)

    Zhu, Qing; Zhang, Jinlian; Yang, Ping; Tan, Bo; Liu, Xinhua; Zheng, Yuanting; Cai, Weimin; Zhu, Yizhun

    2014-01-01

    Leonurine, a major bioactive component from Herba Leonuri, shows therapeutic potential for cardiovascular disease and stroke prevention in some preclinical experiments. The aim of this study is to characterize metabolites of leonurine in rats using high performance liquid chromatography coupled with tandem mass spectrometry (HPLC/MS/MS). The chromatographic separation was performed on an Agilent ZORBAX SB-C18 column using a gradient elution with acetonitrile/ammonium acetate buffer (10 mM, pH 4.0) solvent system. An information dependent acquisition (IDA) method was developed for screening and identifying metabolites of leonurine under positive ion mode. Compared with control, the interesting compound in the extracted ion chromatogram (XIC) of the in vivo samples was chosen and further identified by analyzing their retention times, changes in observed mass (Δm/z), and spectral patterns of product ion utilizing advanced software tool. For the first time, a total of three metabolites were identified, including two phase II metabolites generated by glucuronidation (M1) and sulfation (M2) and one phase I metabolite formed by O-demethylation (M3). Finally, the lead metabolite M1 was isolated from urine and its structure was characterized as leonurine-10-O- β-D-glucuronide by NMR spectroscopy (¹H, ¹³C, HMBC, and HSQC).

  8. Determination of rivaroxaban in patient’s plasma samples by anti-Xa chromogenic test associated to High Performance Liquid Chromatography tandem Mass Spectrometry (HPLC-MS/MS)

    Science.gov (United States)

    Derogis, Priscilla Bento Matos; Sanches, Livia Rentas; de Aranda, Valdir Fernandes; Colombini, Marjorie Paris; Mangueira, Cristóvão Luis Pitangueira; Katz, Marcelo; Faulhaber, Adriana Caschera Leme; Mendes, Claudio Ernesto Albers; Ferreira, Carlos Eduardo dos Santos; França, Carolina Nunes; Guerra, João Carlos de Campos

    2017-01-01

    Rivaroxaban is an oral direct factor Xa inhibitor, therapeutically indicated in the treatment of thromboembolic diseases. As other new oral anticoagulants, routine monitoring of rivaroxaban is not necessary, but important in some clinical circumstances. In our study a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was validated to measure rivaroxaban plasmatic concentration. Our method used a simple sample preparation, protein precipitation, and a fast chromatographic run. It was developed a precise and accurate method, with a linear range from 2 to 500 ng/mL, and a lower limit of quantification of 4 pg on column. The new method was compared to a reference method (anti-factor Xa activity) and both presented a good correlation (r = 0.98, p highly correlated and should be used as clinical tools for drug monitoring. The method was applied successfully in a group of 49 real-life patients, which allowed an accurate determination of rivaroxaban in peak and trough levels. PMID:28170419

  9. High-sensitivity simultaneous liquid chromatography–tandem mass spectrometry assay of ethinyl estradiol and levonorgestrel in human plasma

    Directory of Open Access Journals (Sweden)

    Abhishek Gandhi

    2015-10-01

    Full Text Available A sensitive and simultaneous liquid chromatography–tandem mass spectrometry method was developed and validated for quantification of ethinyl estradiol and levonorgestrel. The analytes were extracted with methyl-tert-butyl ether: n-hexane (50:50, v/v solvent mixture, followed by dansyl derivatization. The chromatographic separation was performed on a Kinetex C18 (50 mm×4.6 mm, 2.6 µm column with a mobile phase of 0.1% (v/v formic acid in water and acetonitrile in gradient composition. The mass transitions were monitored in electrospray positive ionization mode. The assay exhibited a linear range of 0.100–20.0 ng/mL for levonorgestrel and 4.00–500 pg/mL for ethinyl estradiol in human plasma. A run time of 9.0 min for each sample made it possible to analyze a throughput of more than 100 samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic and bioequivalence studies. Keywords: Ethinyl estradiol, Levonorgestrel, LC–MS/MS, Human plasma, Derivatization

  10. Determination of asperosaponin VI in dog plasma by high-performance liquid chromatography-tandem mass spectrometry and its application to a pilot pharmacokinetic study.

    Science.gov (United States)

    Shakya, Shailendra; Zhu, He; Ding, Li; Du, Xiao Lang; Qi, Xie Min; Yang, Xiao Lin; Yang, Zhong Lin

    2012-01-01

    A sensitive and rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the determination of asperosaponin VI in beagle dog plasma using glycyrrhizic acid as the internal standard (IS). Plasma samples were simply pretreated with methanol for deproteinization. Chromatographic separation was performed on a Hedera ODS-2 column using mobile phase of methanol-10 mm ammonium acetate buffer solution containing 0.05% acetic acid (71:29, v/v) at a flow rate of 0.38 mL/min. Asperosaponin VI and the IS were eluted at 2.8 and 1.9 min, respectively, ionized in negative ion mode, and then detected by multiple reaction monitoring. The detection used the transitions of the deprotonated molecules at m/z 927.5 → 603.4 for asperosaponin VI and m/z 821.4 → 645.4 for glycyrrhizic acid (IS). The assay was linear over the concentration range of 0.15-700 ng/mL and was successfully applied to a pilot pharmacokinetic study in beagle dogs. Copyright © 2011 John Wiley & Sons, Ltd.

  11. Sensitive measurement of vinorelbine in dog plasma by liquid chromatography-electrospray ionization tandem mass spectrometry utilizing transitions from double-charged precursor ions.

    Science.gov (United States)

    Niwa, Makoto; Kawashiro, Takashi

    2011-04-01

    A sensitive high-performance liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for measuring vinorelbine was developed. A 100 µL aliquot of plasma was spiked with deuterium-labeled internal standard and subjected to solid-phase extraction using an Oasis HLB μ-elution plate. Two microliters of the extracted samples was directly injected into LC/MS/MS. Chromatographic separation was achieved on a Capcell Pak C18 UG column (2 × 75 mm) with a gradient elution of methanol (mobile phase B) against 0.05% formic acid in aqueous 10 mm ammonium formate (mobile phase A). The LC flow rate was set to 0.28 mL/min and the gradient (solvent B concentration) was processed from 40 to 90%. In mass spectrometric detection, observation of the reaction from a double-charged precursor ion [M + 2H](2+) (m/z 390) to product ion m/z 122 provided very high sensitivity. The method was validated with a lower limit of detection of 0.2 ng/mL with 0.1 mL of plasma, and the method was used to determine the plasma pharmacokinetics of vinorelbine in dogs. Copyright © 2010 John Wiley & Sons, Ltd.

  12. Development of a fast liquid chromatography-tandem mass spectrometry method for the determination of endocrine-disrupting compounds in waters.

    Science.gov (United States)

    Di Carro, Marina; Scapolla, Carlo; Liscio, Camilla; Magi, Emanuele

    2010-09-01

    A fast liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS-MS) method was developed to study five endocrine-disrupting compounds (4-n-nonylphenol, bisphenol A, estrone, 17β-estradiol and 17α-ethinylestradiol) in water. Different columns were tested; the chromatographic separation of the analytes was optimized on a Pinnacle DB biphenylic column with a water-acetonitrile gradient elution, which allowed the separation of the selected endocrine-disrupting compounds (EDCs) in less than 6 min. Quantitative analysis was performed in selected reaction monitoring (SRM) mode; two transitions were chosen for each compound, using the most abundant for quantitation. Calibration curves using bisphenol A-d (16) as internal standard were drawn, showing good correlation coefficients (0.9993-0.9998). All figures of merit of the method were satisfactory; limits of detection were in the low pg range for all analytes. The method was then applied to the determination of the analytes in real water samples: to this aim, polar organic chemical integrative samplers (POCIS) were deployed in the influent and in the effluent of a drinking water treatment plant in Liguria (Italy). The EDC level was rather low in the influent and negligible in the outlet, reflecting the expected function of the treatment plant.

  13. Simple and Sensitive Analysis of Blonanserin and Blonanserin C in Human Plasma by Liquid Chromatography Tandem Mass Spectrometry and Its Application

    Directory of Open Access Journals (Sweden)

    Yunliang Zheng

    2014-01-01

    Full Text Available A highly sensitive, simple, and rapid liquid chromatography tandem mass spectrometry method to simultaneously determine blonanserin and blonanserin C in human plasma with AD-5332 as internal standard (IS was established. A simple direct protein precipitation method was used for the sample pretreatment, and chromatographic separation was performed on a Waters XBridge C8 (4.6×150 mm, 3.5 μm column. The mobile phase consists of a mixture of 10 mM ammonium formate and 0.1% formic acid in water (A and 0.1% formic acid in methanol (B. To quantify blonanserin, blonanserin C, and IS, multiple reaction monitoring (MRM was performed in positive ESI mode. The calibration curve was linear in the concentration range of 0.012–5.78 ng·mL−1 for blonanserin and 0.023–11.57 ng·mL−1 for blonanserin C (r2>0.9990. The intra- and interday precision of three quality control (QC levels in plasma were less than 7.5%. Finally, the current simple, sensitive, and accurate LC-MS/MS method was successfully applied to investigate the pharmacokinetics of blonanserin and blonanserin C in healthy Chinese volunteers.

  14. Monitoring utilizations of amino acids and vitamins in culture media and Chinese hamster ovary cells by liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Qiu, Jinshu; Chan, Pik Kay; Bondarenko, Pavel V

    2016-01-05

    Monitoring amino acids and vitamins is important for understanding human health, food nutrition and the culture of mammalian cells used to produce therapeutic proteins in biotechnology. A method including ion pairing reversed-phase liquid chromatography with tandem mass spectrometry was developed and optimized to quantify 21 amino acids and 9 water-soluble vitamins in Chinese hamster ovary (CHO) cells and culture media. By optimizing the chromatographic separation, scan time, monitoring time window, and sample preparation procedure, and using isotopically labeled (13)C, (15)N and (2)H internal standards, low limits of quantitation (≤0.054 mg/L), good precision (culture media. In a fed-batch process of manufacturing scale bioreactors, two distinguished trends for changes in amino acid concentrations were identified in response to feeding. Ten essential amino acids showed a zigzag pattern with maxima at the feeding days, and 9 non-essential amino acids displayed a smoothly changing profile as they were mainly products of cellular metabolism. Five of 9 vitamins accumulated continuously during the culture period, suggesting that they were fed in access. The method serves as an effective tool for the development and optimization of mammalian cell cultures. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Comparative analysis of the main bioactive components of Xin-Sheng-Hua granule and its single herbs by ultrahigh performance liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Pang, Hanqing; Wang, Jun; Tang, Yuping; Xu, Huiqin; Wu, Liang; Jin, Yi; Zhu, Zhenhua; Guo, Sheng; Shi, Xuqin; Huang, Shengliang; Sun, Dazheng; Duan, Jin-Ao

    2016-11-01

    Xin-Sheng-Hua granule, a representative formula for postpartum hemorrhage, has been used clinically to treat postpartum diseases. Its main bioactive components comprise aromatic acids, phthalides, alkaloids, flavonoids, and gingerols among others. To investigate the changes in main bioactive constituents in its seven single herbs before and after compatibility, a rapid, simple, and sensitive method was developed for comparative analysis of 27 main bioactive components by using ultrahigh-performance liquid chromatography with triple quadrupole electrospray tandem mass spectrometry for the first time. The sufficient separation of 27 target constituents was achieved on a Thermo Scientific Hypersil GOLD column (100 mm × 3 mm, 1.9 μm) within 20 min under the optimized chromatographic conditions. Compared with the theoretical content, the observed content of each analyte showed remarkable differences in Xin-Sheng-Hua granule except thymine, p-coumaric acid, senkyunolide I, senkyunolide H, and ligustilide; the total contents of 27 components increased significantly, and the content variation degrees for the different components were gingerols > flavonoids > aromatic acids > alkaloids > phthalides. The results could provide a good reference for the quality control of Xin-Sheng-Hua granule and might be helpful to interpret the drug interactions based on variation of bioactive components in formulae. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Analysis of processing contaminants in edible oils. Part 1. Liquid chromatography-tandem mass spectrometry method for the direct detection of 3-monochloropropanediol monoesters and glycidyl esters.

    Science.gov (United States)

    MacMahon, Shaun; Mazzola, Eugene; Begley, Timothy H; Diachenko, Gregory W

    2013-05-22

    A new analytical method has been developed and validated for the detection of glycidyl esters (GEs) and 3-monochloropropanediol (3-MCPD) monoesters in edible oils. The target compounds represent two classes of potentially carcinogenic chemical contaminants formed during the processing of edible oils. Target analytes are separated from edible oil matrices using a two-step solid-phase extraction (SPE) procedure. The extracts are then analyzed using liquid chromatography-tandem mass spectrometry (LC-MS/MS) with electrospray ionization (ESI). Chromatographic conditions that separate sn-1 and sn-2 monoesters of 3-MCPD have been developed for the first time. The method has been validated for GEs, sn-1 3-MCPD monoesters of lauric, myristic, linolenic, linoleic, oleic, and stearic acids, and sn-2 3-MCPD monoesters of oleic and palmitic acids in coconut, olive, and palm oils using an external calibration curve. The range of average recoveries and relative standard deviations (RSDs) across the three oil matrices at three spiking concentrations are 84-115% (3-16% RSD) for the GEs, 95-113% (1-10% RSD) for the sn-1 3-MCPD monoesters, and 76.8-103% (5.1-11.2% RSD) for the sn-2 3-MCPD monoesters, with limits of quantitation at or below 30 ng/g for the GEs, 60 ng/g for sn-1 3-MCPD monoesters, and 180 ng/g for sn-2 3-MCPD monoesters.

  17. Analysis of processing contaminants in edible oils. Part 2. Liquid chromatography-tandem mass spectrometry method for the direct detection of 3-monochloropropanediol and 2-monochloropropanediol diesters.

    Science.gov (United States)

    MacMahon, Shaun; Begley, Timothy H; Diachenko, Gregory W

    2013-05-22

    A method was developed and validated for the detection of fatty acid diesters of 2-monochloropropanediol (2-MCPD) and 3-monochloropropanediol (3-MCPD) in edible oils. These analytes are potentially carcinogenic chemical contaminants formed during edible oil processing. After separation from oil matrices using a two-step solid-phase extraction (SPE) procedure, the target compounds are quantitated using liquid chromatography-tandem mass spectrometry (LC-MS/MS) with electrospray ionization (ESI). The first chromatographic conditions have been developed that separate intact diesters of 2-MCPD and 3-MCPD, allowing for their individual quantitation. The method has been validated for 28 3-MCPD diesters of lauric, myristic, palmitic, linolenic, linoleic, oleic, and stearic acids in coconut, olive, and palm oils, as well as 3 2-MCPD diesters, using an external calibration curve. The range of average recoveries and relative standard deviations (RSDs) across the three oil matrices at three spiking concentrations are 88-118% (2-16% RSD) with maximum limits of quantitation of 30 ng/g (ppb).

  18. Rapid determination of some psychotropic drugs in complex matrices by tandem dispersive liquid-liquid microextraction followed by high performance liquid chromatography.

    Science.gov (United States)

    Asghari, Alireza; Fahimi, Ebrahim; Bazregar, Mohammad; Rajabi, Maryam; Boutorabi, Leila

    2017-05-01

    Simple and rapid determinations of some psychotropic drugs in some pharmaceutical wastewater and human plasma samples were successfully accomplished via the tandem dispersive liquid-liquid microextraction combined with high performance liquid chromatography-ultraviolet detection (TDLLME-HPLC-UV). TDLLME of the three psychotropic drugs clozapine, chlorpromazine, and thioridazine was easily performed through two consecutive dispersive liquid-liquid microextractions. By performing this convenient method, proper sample preconcentrations and clean-ups were achieved in just about 7min. In order to achieve the best extraction efficiency, the effective parameters involved were optimized. The optimal experimental conditions consisted of 100μL of CCl 4 (as the extraction organic solvent), and the pH values of 13 and 2 for the donor and acceptor phases, respectively. Under these optimum experimental conditions, the proposed TDLLME-HPLC-UV technique provided a good linearity in the range of 5-3000ngmL -1 for the three psychotropic drugs with the correlation of determinations (R 2 s) higher than 0.996. The limits of quantification (LOQs) and limits of detection (LODs) obtained were 5.0ngmL -1 and 1.0-1.5ngmL -1 , respectively. Also the proper enrichment factors (EFs) of 96, 99, and 88 for clozapine, chlorpromazine, and thioridazine, respectively, and good extraction repeatabilities (relative standard deviations below 9.3%, n=5) were obtained. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Simultaneous determination of gallic acid and gentisic acid in organic anion transporter expressing cells by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Wang, Li; Halquist, Matthew S; Sweet, Douglas H

    2013-10-15

    In order to elucidate the role of organic anion transporters (OATs) in the renal elimination of gallic acid and gentisic acid, a new, rapid, and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the simultaneous determination of gallic acid and gentisic acid in cell lysate, using Danshensu as the internal standard (IS). After a simple liquid-liquid extraction, the analytes were detected in negative ESI mode using selected reaction monitoring. The precursor-to-product ion transitions (m/z) were 169.0→125.0, 153.1→108.0, and 196.8→135.2 for gallic acid, gentisic acid, and the IS, respectively. Chromatographic separation was achieved on a C18 column using mobile phases consisting of water with 0.1% acetic acid (A) and acetonitrile with 0.05% formic acid. (B) The total run time was 3min and calibration curves were linear over the concentrations of 0.33-2400ng/mL for both compounds (r(2)>0.995). Good precision (between 3.11% and 14.1% RSD) and accuracy (between -12.7% and 11% bias) was observed for quality controls at concentrations of 0.33 (lower limit of quantification), 1, 50, and 2000ng/mL. The mean extraction recovery of gallic acid and gentisic acid was 80.7% and 83.5%, respectively. Results from post-column infusion and post-extraction methods indicated that the analytical method exhibited negligible matrix effects. Finally, this validated assay was successfully applied in a cellular uptake study to determine the intracellular concentrations of gallic acid and gentisic acid in OAT expressing cells. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Method development and validation of liquid chromatography-tandem/mass spectrometry for aldosterone in human plasma: Application to drug interaction study of atorvastatin and olmesartan combination

    Directory of Open Access Journals (Sweden)

    Rakesh Das

    2014-01-01

    Full Text Available In the present investigation, a simple and sensitive liquid chromatography-tandem mass spectrometry (LC/MS/MS method was developed for the quantification of aldosterone (ALD a hormone responsible for blood pressure in human plasma. The developed method was validated and extended for application on human subjects to study drug interaction of atorvastatin (ATSV and olmesartan (OLM on levels of ALD. The ALD in plasma was extracted by liquid-liquid extraction with 5 mL dichloromethane/ethyl ether (60/40% v/v. The chromatographic separation of ALD was carried on Xterra, RP-Column C18 (150 mm× 4.6 mm × 3.5 μm at 30°C followed by four-step gradient program composed of methanol and water. Step 1 started with 35% methanol for first 1 min and changed linearly to 90% in next 1.5 min in Step 2. Step 3 lasted for next 2 min with 90% methanol. The method finally concluded with Step 4 to achieve initial concentration of methanol that is, 35% thus contributing the total method run time of 17.5 min. The flow rate was 0.25 mL/min throughout the process. The developed method was validated for specificity, accuracy, precision, stability, linearity, sensitivity, and recovery. The method was linear and found to be acceptable over the range of 50-800 ng/mL. The method was successfully applied for the drug interaction study of ATSV + OLM in combination against OLM treatment on blood pressure by quantifying changes in levels of ALD in hypertensive patients. The study revealed levels of ALD were significantly higher in ATSV + OLM treatment condition when compared to OLM as single treated condition. This reflects the reason of low effectiveness of ATSV + OLM in combination instead of synergistic activity.

  1. Simultaneous determination of flurbiprofen and its hydroxy metabolite in human plasma by liquid chromatography-tandem mass spectrometry for clinical application.

    Science.gov (United States)

    Lee, Hye-In; Choi, Chang-Ik; Byeon, Ji-Yeong; Lee, Jung-Eun; Park, So-Young; Kim, Young-Hoon; Kim, Se-Hyung; Lee, Yun-Jeong; Jang, Choon-Gon; Lee, Seok-Yong

    2014-11-15

    Flurbiprofen (FLB) is one of the phenylalkanoic acid derivatives of non-steroidal anti-inflammatory drugs used for the management of pain and inflammation in patients with arthritis. We developed and validated a rapid and sensitive high-performance liquid chromatography analytical method utilizing tandem mass spectrometry (HPLC-MS/MS) for the simultaneous determination of FLB and its major metabolite, 4'-hydroxyflurbiprofen (4'-OH-FLB), in human plasma. Probenecid was used as an internal standard (IS). After liquid-liquid extraction with methyl t-butyl ether, chromatographic separation of the two analytes was achieved using a reversed-phase Luna C18 column (2.0mm×50mm, 5μm particles) with a mobile phase of 10mM ammonium formate buffer (pH 3.5)-methanol (15:85, v/v) and quantified by MS/MS detection in ESI negative ion mode. The flow rate of the mobile phase was 250μl/min and the retention times of FLB, 4'-OH-FLB, and IS were 1.1, 0.8, and 0.9min, respectively. The calibration curves were linear over a range of 0.01-10μg/ml for FLB and 0.01-1μg/ml for 4'-OH-FLB. The lower limit of quantifications using 100μl of human plasma was 0.01μg/ml for both analytes. The mean accuracy and precision for intra- and inter-run validation of FLB and 4'-OH-FLB were all within acceptable limits. The present HPLC-MS/MS method showed improved sensitivity for quantification of the FLB and its major metabolite in human plasma compared with previously described analytical methods. The validated method was successfully applied to a pharmacokinetic study in humans. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Determination of oxycodone and its major metabolites noroxycodone and oxymorphone by ultra-high-performance liquid chromatography tandem mass spectrometry in plasma and urine: application to real cases.

    Science.gov (United States)

    Pantano, Flaminia; Brauneis, Stefano; Forneris, Alexandre; Pacifici, Roberta; Marinelli, Enrico; Kyriakou, Chrystalla; Pichini, Simona; Busardò, Francesco Paolo

    2017-08-28

    Oxycodone is a narcotic drug widely used to alleviate moderate and severe acute and chronic pain. Variability in analgesic efficacy could be explained by inter-subject variations in plasma concentrations of parent drug and its active metabolite, oxymorphone. To evaluate patient compliance and to set up therapeutic drug monitoring (TDM), an ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) assay was developed and validated for the parent drug and its major metabolites noroxycodone and oxymorphone. Extraction of analytes from plasma and urine samples was obtained by simple liquid-liquid extraction. The chromatographic separation was achieved with a reversed phase column using a linear gradient elution with two solvents: acetic acid 1% in water and methanol. The separated analytes were detected with a triple quadrupole mass spectrometer operated in multiple reaction monitoring (MRM) mode via positive electrospray ionization (ESI). Separation of analytes was obtained in less than 5 min. Linear calibration curves for all the analytes under investigation in urine and plasma samples showed determination coefficients (r2) equal or higher than 0.990. Mean absolute analytical recoveries were always above 86%. Intra- and inter-assay precision (measured as coefficient of variation, CV%) and accuracy (measured as % error) values were always better than 13%. Limit of detection at 0.06 and 0.15 ng/mL and limit of quantification at 0.2 and 0.5 ng/mL for plasma and urine samples, respectively, were adequate for the purpose of the present study. Rapid extraction, identification and quantification of oxycodone and its metabolites both in urine and plasma by UHPLC-MS/MS assay was tested for its feasibility in clinical samples and provided excellent results for rapid and effective drug testing in patients under oxycodone treatment.

  3. A fast liquid chromatography-tandem mass spectrometry method for determining benzodiazepines and analogues in urine. Validation and application to real cases of forensic interest.

    Science.gov (United States)

    Salomone, Alberto; Gerace, Enrico; Brizio, Paola; Gennaro, M Carla; Vincenti, Marco

    2011-11-01

    A fast liquid chromatographic/tandem mass spectrometric method was developed for the simultaneous determination in human urine of seventeen benzodiazepines, four relevant metabolites together plus zolpidem and zopiclone. The sample preparation, optimized to take into account the matrix effect, was based on enzymatic hydrolysis and liquid-liquid extraction. The separation of the twenty-three analytes was achieved in less than eight minutes. The whole methodology was fully validated according to UNI EN ISO/IEC 17025:2005 rules and 2006 SOFT/AAFS guidelines. Selectivity, linearity range, identification (LOD) and quantitation (LOQ) limits, precision, accuracy and recovery were evaluated. For all the species the signal/concentration linearity was satisfactory in the 50-1000 ng/mL concentration range. The limits of detection ranged from 0.5 to 30 ng/mL and LOQs from 1.7 to 100.0 ng/mL. Precisions were in the ranges 5.0-11.8%, 1.5-11.0% and 1.1-4.4% for low (100 ng/mL), medium (300 ng/mL) and high (1000 ng/mL) concentration, respectively. The accuracy, expressed as bias% was within ± 25 % for all the analytes. The recovery values, evaluated at 300 ng/mL concentration, ranged from 56.2% to 98.8%. The present method for the determination of several benzodiazepines, zolpidem and zopiclone in human urine proved to be simple, fast, specific and sensitive. The quantification by LC-MS/MS was successfully applied to 329 forensic cases among driving re-licensing, car accidents and alleged sexual violence cases. Copyright © 2011 Elsevier B.V. All rights reserved.

  4. Simple and sensitive high performance liquid chromatographic method for the simultaneous quantitation of the phenylalanine in human plasma

    Directory of Open Access Journals (Sweden)

    Hossein Danafar

    2015-09-01

    Full Text Available Phenylalanine (Phe is the most reliable indicator for the diagnosis of phenylketonuria (PKU. The purpose of this study is to establish a reliable and quick method for the assignment of Phe in peripheral capillary blood from newborns and children by high performance liquid chromatography with ultraviolet detection (HPLC-UV. PKU is an inborn error of metabolism characterized by the inability of the body to use Phe. A rapid and sensitive high performance liquid chromatographic (HPLC method has been developed for determination of Phe in plasma. The method uses a protein precipitation step with sulfosalicilic acid for sample preparation by separation on a Nova-pack C18 column using sodium acetate buffer and acetonitrile (94: 6 v/v adjusted to pH 6.5 with glacial acetic acid. The eluted peaks detected by a UV detector was set at wavelength of 215 nm. The method was validated in the range of Phe concentrations from 0.1 to 20 µg/ml. The limits of detection (LOD and quantitation (LOQ of the method were 0.05 and 0.1 µg/ml, respectively. The average drug recovery from plasma was 88.60 percent throughout the linear concentration range., with the average within-run and between-run accuracy values of 103.3 and 115.350, respectively. The method is quick, easy, very steady and precise for the screen, assignment, and evaluation of Phe in human plasma by HPLC, which is particularly a useful way for screening and diagnosis of PKU and monitoring of a diet therapy.

  5. Determination of rare earth elements by liquid chromatographic separation using inductively coupled plasma mass spectrometric detection

    International Nuclear Information System (INIS)

    Braverman, D.S.

    1992-01-01

    High-performance liquid chromatography (HPLC) is used to separate the rare earth elements (REEs) prior to detection by inductively coupled plasma mass spectrometry (ICP-MS). The use of HPLC-ICP-MS in series combines the separation power and speed of HPLC with the sensitivity, isotopic selectivity and speed of ICP-MS. The detection limits for the REEs are in the sub-ng ml -1 range and the response is linear over four orders of magnitude. A preliminary comparison of isotope dilution and external standard results for the determination of REEs in National Institute of Standards and Technology (NIST) Standard Reference Material (SRM 1633a) Fly Ash is presented. (author)

  6. Solid-phase extraction and high-performance liquid chromatographic separation of pigments of red wines.

    Science.gov (United States)

    Csiktusnádi Kiss, G A; Forgács, E; Cserháti, T; Candeias, M; Vilas-Boas, L; Bronze, R; Spranger, I

    2000-08-11

    The adsorption and desorption capacities of 11 different solid-phase extraction sorbents were tested for the preconcenration of pigments of various Hungarian red wines. The concentrates were evaluated by multiwavelengh spectrophotometry combined with a spectral mapping technique (SPM) and by reversed-phase high-performance liquid chromatography. The highest (10-fold) concentration of pigments was achieved on octadecylsilica sorbent. It can be used five times without losing adsorption and desorption characteristics. SPM indicated that multiwavelength spectrophotometry can be employed for the differentiation of red wines. Comparison of the chromatograms of pigments with and without preconcentration showed that preconcentration makes possible the separation and detection of pigments present in low concentration in red wines.

  7. Comparison of liquid chromatographic and bioassay procedures for determining depletion of intramuscularly injected tylosin.

    Science.gov (United States)

    Moats, W A; Harris, E W; Steele, N C

    1985-01-01

    Crossbred pigs weighing 80-110 kg were injected intramuscularly in the ham with 8.8 mg/kg tylosin. Animals were slaughtered in groups of 3 at intervals of 4 h, and 1, 2, 4, and 8 days after injection, and samples of blood, injected muscle, uninjected muscle, liver, and kidney were analyzed by liquid chromatography (LC) and by bioassay using Sarcina lutea as the test organism. The LC method was far more sensitive with a detection limit of less than 0.1 ppm, while the detection limit by bioassay was about 0.5 ppm in tissue. Results by bioassay and LC sometimes differed considerably for tissue samples. Residues in all tissues were below the tolerance limit of 0.2 ppm at 24 h, except in the injected muscle in one animal. Residues were not detected in any tissue of any animal at 48 h after treatment.

  8. A narrow open tubular column for high efficiency liquid chromatographic separation.

    Science.gov (United States)

    Chen, Huang; Yang, Yu; Qiao, Zhenzhen; Xiang, Piliang; Ren, Jiangtao; Meng, Yunzhu; Zhang, Kaiqi; Juan Lu, Joann; Liu, Shaorong

    2018-04-30

    We report a great feature of open tubular liquid chromatography when it is run using an extremely narrow (e.g., 2 μm inner diameter) open tubular column: more than 10 million plates per meter can be achieved in less than 10 min and under an elution pressure of ca. 20 bar. The column is coated with octadecylsilane and both isocratic and gradient separations are performed. We reveal a focusing effect that may be used to interpret the efficiency enhancement. We also demonstrate the feasibility of using this technique for separating complex peptide samples. This high-resolution and fast separation technique is promising and can lead to a powerful tool for trace sample analysis.

  9. High-performance liquid chromatographic assay for the determination of Aloe Emodin in mouse plasma.

    Science.gov (United States)

    Zaffaroni, M; Mucignat, C; Pecere, T; Zagotto, G; Frapolli, R; D'Incalci, M; Zucchetti, M

    2003-10-25

    An isocratic high-performance liquid chromatography (HPLC) method was developed and validated to determine Aloe Emodin (AE) in mouse plasma. The analysis required 0.3 ml of plasma and involves extraction with dichloromethane. The HPLC separation was carried out on Symmetry Shield RP18, a mobile phase of methanol-water-acetic acid (65:35:0.2) and fluorescence detection at lambda(ex)=410 nm and lambda(em)=510 nm. The retention time of AE was 11.7 min. The assay was linear from 10 to 1,000 ng/ml (r2 > or = 0.999), showed intra- and inter-day precision within 7.8 and 4.7%, and accuracy of 87.3-105.7%. Detection limit (LOD) and quantification limit (LOQ) were 4.5 and 5 ng/ml, respectively. The method was applied to determine for the first time the pharmacokinetic of AE in mice.

  10. Ultra-performance liquid chromatographic determination of tocopherols and retinol in human plasma.

    Science.gov (United States)

    Bell, Edward C; John, Mathew; Hughes, Rodney J; Pham, Thu

    2014-10-01

    A rapid, selective and sensitive ultra-performance liquid chromatography method has been developed for the detection and quantification of tocopherols and retinol in human plasma. Alpha-tocopherol, gamma-tocopherol and retinol are assayed using fluorescence detection. Excitation/emission wavelengths are 295/330 nm and 325/470 nm for the analysis of both tocopherols and retinol, respectively. Retinol acetate is employed as the internal standard. The reversed-phase method incorporates gradient elution with a mobile phase consisting of methanol and acetonitrile. Separation of vitamin compounds is achieved using a bridged ethyl hybrid C18 column. The retention times for retinol, retinol acetate, gamma-tocopherol and alpha-tocopherol are 1.6, 1.8, 3.9 and 4.3 min, respectively. The limits of quantification for retinol, gamma-tocopherol and alpha-tocopherol were 0.02, 0.02 and 0.1 µg/mL, respectively. The assay method is suitable for the analysis of tocopherols and retinol in human plasma. The method may be applied following the ingestion of foods fortified with these fat-soluble vitamins. © The Author [2013]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  11. High-Performance Liquid Chromatographic Ultraviolet Determination of Memantine Hydrochloride after In Vitro Transdermal Diffusion Studies

    Directory of Open Access Journals (Sweden)

    Sergio del Rio-Sancho

    2013-01-01

    Full Text Available The purpose of the present work was to validate an accurate and precise high-performance liquid chromatography (HPLC method involving ultraviolet detection for the quantitative analysis of memantine hydrochloride. In order to analyze a molecule with no chromophoric groups that could be detected by a UV/visible detector, it was necessary to extract the drug and to perform a dansylation reaction that enabled the UV/visible detection of the derivatized molecule. Separation was carried out with a 150 mm Kromasil C18 column at room temperature. The detection response, at 218 nm, was found to be linear in the concentration range from 0.5 to 50 μg/mL. The method was validated for specificity, linearity, precision, accuracy, limit of detection, limit of quantification, and robustness. The limit of detection (LOD was 0.144 μg/mL, and the limit of quantification (LOQ was 0.437 μg/mL. The dansylated memantine complex was stable for at least five days in all the conditions evaluated. The potential use of this method has been demonstrated by the quantification of memantine hydrochloride contained in samples from the study of its in vitro transdermal permeation.

  12. A simple high-performance liquid chromatographic practical approach for determination of flurbiprofen

    Directory of Open Access Journals (Sweden)

    Muhammad Akhlaq

    2011-01-01

    Full Text Available A simple, rapid, sensitive, and specific high-performance liquid chromatography (HPLC assay for flurbiprofen has been developed and validated practically. The chromatography was conducted using Gemini C18 column (5 μm; 4.6 mm × 250 mm, Phenomenex, California, USA. The mobile phase containing disodium hydrogen phosphate solution (30 mM pH 7.0 and acetonitrile (50:50; and the isocratic flow rate of 1.0 ml/min were used in the current study. Detection was made at 247 nm. The calibration curve was linear (r ≥ 0.9996 over the concentration range of 5-50 mm/ml. Mean percentage (% recovery ± % relative standard deviation (RSD ranged from 97.07 ± 0.008 to 103.66 ± 0.013. Within-day and between-day precision were also in acceptable range of 98.83 ± 0.004 to 104.56 ± 0.009. In order to confirm the practical applicability of the method developed, flurbiprofen controlled release matrix tablets were subjected to the dissolution studies and the release rate was analyzed. The reported HPLC for flurbiprofen provides several advantages of simplicity, high specificity, accuracy, and very short run-cycle time. It is suggested that the method should be used for the routine quality control analysis of flurbiprofen pure drug and its dosage forms.

  13. High-performance liquid chromatographic quantification of rifampicin in human plasma: method for Therapecutic drug monitoring

    International Nuclear Information System (INIS)

    Sameh, T.; Hanene, E.; Jebali, N.

    2013-01-01

    A high performance liquid chromatography (HPLC) method has been developed that allows quantification of Rifampicin in human plasma. The method is based on the precipitation of proteins in human plasma with methanol. Optimal assay conditions were found with a C18 column and a simple mobile phase consisting of 0.05 M dipotassic hydrogen phosphate buffer and acetonitrile (53/47, V/V) with 0.086 % diethylamin, pH = 4.46. The flow-rate was 0.6 ml /mm and the drug was monitored at 340 nm. Results from the HPLC analyses showed that the assay method is linear in the concentration range of 1-40 micro g/ml, (r2 >0.99). The limit of quantification and limit of detection of Rifampicin were 0.632 micro g/ml and 0.208 micro g/ml, respectively. Intraday and interday coefficient of variation and bias were below 10% for all samples, suggesting good precision and accuracy of the method. Recoveries were greater than 90% in a plasma sample volume of 100 micro l. The method is being successfully applied to therapeutic drug monitoring of Rifapicin in plasma samples of tuberculosis and staphylococcal infections patients. (author)

  14. Monitoring salivary melatonin concentrations in children with sleep disorders using liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Khan, Sohil A; George, Rani; Charles, Bruce G; Taylor, Paul J; Heussler, Helen S; Cooper, David M; McGuire, Treasure M; Pache, David; Norris, Ross L G

    2013-06-01

    Melatonin is synthesized in the pineal gland and is an important circadian phase marker, especially in the determination of sleep patterns. Both temporary and permanent abnormal sleep patterns occur in children; therefore, it is desirable to have methods for monitoring melatonin in biological fluids in the diagnosis and treatment of such disorders. The objective of the study is to develop a liquid chromatography-tandem mass spectrometry method for the determination of melatonin in saliva and to apply it to monitoring salivary concentrations in children with sleep disorders. A deuterated internal standard (d7-melatonin) was added to a diluted saliva sample (20 µL) in an autosampler vial insert, and 50 µL were injected. Plasticware was strictly avoided, and all glassware was scrupulously cleaned and then baked at 120°C for at least 48 hours to obtain satisfactory performance. Reverse-phase chromatography was performed on a C8 column using a linear gradient elution profile comprising mobile phases A (0.1% aqueous formic acid) and B (15% methanol in acetonitrile containing 0.1% formic acid), pumped at a total flow rate of 0.8 mL/min. The run time was 8 minutes. After atmospheric pressure chemical ionization, mass spectrometric detection was in positive ion mode. Mass detection was by selected reaction monitoring mode with the following mass transitions used for quantification: melatonin, m/z 233.0 → 173.8 and d7-melatonin, m/z 240.0 → 178.3. Linearity (r > 0.999) was established from 3.9 to 1000 pg/mL. Imprecision (coefficient of variation percent) was less than 11%, and accuracy was 100-105% (7.0-900 pg/mL). The method was selective, and the mean (range) ratio of the slopes of calibrations in water to those in daytime saliva samples collected from 10 healthy adult subjects was 0.989 (0.982-0.997), indicating negligible matrix effects. The application of the assay was demonstrated in healthy adults and in children being clinically investigated for sleep

  15. Combination of solvent extractants for dispersive liquid-liquid microextraction of fungicides from water and fruit samples by liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Pastor-Belda, Marta; Garrido, Isabel; Campillo, Natalia; Viñas, Pilar; Hellín, Pilar; Flores, Pilar; Fenoll, José

    2017-10-15

    A multiresidue method was developed to determine twenty-five fungicides belonging to three different chemical families, oxazoles, strobilurins and triazoles, in water and fruit samples, using dispersive liquid-liquid microextraction (DLLME) and liquid chromatography/tandem mass spectrometry (LC-MS 2 ). Solid-liquid extraction with acetonitrile was used for the analysis in fruits, the extract being used as dispersant solvent in DLLME. Since some of the analytes showed high affinity for chloroform and the others were more efficiently extracted with undecanol, a mixture of both solvents was used as extractant in DLLME. After evaporation of CHCl 3 , the enriched phase was analyzed. Enrichment factors in the 23-119 and 12-60 ranges were obtained for waters and fruits, respectively. The approach was most sensitive for metominostrobin with limits of quantification of 1ngL -1 and 5ngkg -1 in waters and fruits, respectively, while a similar sensitivity was attained for tebuconazole in fruits. Recoveries of the fungicides varied between 86 and 116%. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Calculation of retention time tolerance windows with absolute confidence from shared liquid chromatographic retention data.

    Science.gov (United States)

    Boswell, Paul G; Abate-Pella, Daniel; Hewitt, Joshua T

    2015-09-18

    Compound identification by liquid chromatography-mass spectrometry (LC-MS) is a tedious process, mainly because authentic standards must be run on a user's system to be able to confidently reject a potential identity from its retention time and mass spectral properties. Instead, it would be preferable to use shared retention time/index data to narrow down the identity, but shared data cannot be used to reject candidates with an absolute level of confidence because the data are strongly affected by differences between HPLC systems and experimental conditions. However, a technique called "retention projection" was recently shown to account for many of the differences. In this manuscript, we discuss an approach to calculate appropriate retention time tolerance windows for projected retention times, potentially making it possible to exclude candidates with an absolute level of confidence, without needing to have authentic standards of each candidate on hand. In a range of multi-segment gradients and flow rates run among seven different labs, the new approach calculated tolerance windows that were significantly more appropriate for each retention projection than global tolerance windows calculated for retention projections or linear retention indices. Though there were still some small differences between the labs that evidently were not taken into account, the calculated tolerance windows only needed to be relaxed by 50% to make them appropriate for all labs. Even then, 42% of the tolerance windows calculated in this study without standards were narrower than those required by WADA for positive identification, where standards must be run contemporaneously. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Simultaneous determination of piracetam and vincamine by spectrophotometric and high-performance liquid chromatographic methods.

    Science.gov (United States)

    El-Saharty, Yasser Shaker Ibrahim

    2008-01-01

    A mixture of piracetam and vincamine was determined by 3 different methods. The first was the determination of piracetam and vincamine using the ratio-spectra first-derivative (DD1) spectrophotometric technique at 209 and 293 nm in concentration ranges of 10-45 and 2-14 microg/mL with mean recoveries of 99.22 +/- 0.72 and 99.67 +/- 0.79%, respectively. The second method was based on the resolution of the 2 components by bivariate calibration depending on a mathematic algorithm that provides simplicity and rapidity. The method depended on quantitative evaluation of the absorbencies at 210 and 225 nm in concentration ranges of 5-45 and 2-14 microg/mL, with mean recoveries of 100.33 +/- 0.54 and 100.44 +/- 0.98% for piracetam and vincamine, respectively. The third method was reversed-phase liquid chromatography using 0.05 M potassium dihydrogen phosphate-methanol (50 + 50, v/v) as the mobile phase, with the pH adjusted to 3.5 with phosphoric acid. The eluent was monitored at 215 nm in concentration ranges of 5-100 and 2-200 microg/mL, with mean recoveries of 99.62 +/- 0.67 and 99.32 +/- 0.85% for piracetam and vincamine, respectively. The suggested procedures were checked using laboratory-prepared mixtures and were successfully applied for the analysis of their pharmaceutical preparation. The methods retained their accuracy and precision when applying the standard addition technique. The results obtained by applying the proposed methods were statistically analyzed and compared with those obtained by the manufacturer's method.

  18. High performance liquid chromatographic method for determination of ezetimibe in pharmaceutical formulation tablets

    Directory of Open Access Journals (Sweden)

    Hossein Danafar

    2016-09-01

    Full Text Available Ezetimide belongs to a class of lipid lowering    compounds    that    selectively    inhibits intestinal   absorption   of   cholesterol   and   related phytosterols. The purpose of this study is to establish a reliable and quick method for the assignment of ezetimibe in tablets form by high performance liquid chromatography with ultraviolet detection (HPLC-UV. A rapid  and  sensitive  HPLC  method  has  been developed  for  determination  of  ezetimibe in tablets formulation.  Mobile phase was composed of acetonitrile-ammonium acetate (10 mM, pH 3.0, 75:25 (v/v with a flow rate of 1 ml/min. The eluted peaks were detected by a UV detector was set at wavelength of 240 nm. The method results in excellent separation with good resolution of analyte. Standard curves were linear (r = 0.996 over the wide ezetimibe concentration range of 10-60.0 µg mL-1 with acceptable accuracy and precision. The limits of detection (LOD and quantitation (LOQ of the method were 5 and 10 µg/ml, respectively. The average drug recovery was 95.3% throughout the linear concentration range. Statistical  assessment  of  various  in  vitro  dissolution  parameters  and  assay  results was  also  conducted  to  establish  if  there were  any significant difference among them. The validated HPLC method has been used successfully to study ezetimibe. Due to simplicity, rapidity and accuracy of the method, we believe that the method will be useful for routine quality control analysis.

  19. Rapid Screening and Characterization of Acetylcholinesterase Inhibitors from Yinhuang Oral Liquid Using Ultrafiltration-liquid Chromatography-electrospray Ionization Tandem Mass Spectrometry.

    Science.gov (United States)

    Zhang, Haomin; Guo, Yinan; Meng, Lingwen; Sun, Hui; Yang, Yinping; Gao, Ying; Sun, Jiaming

    2018-01-01

    At present, approximately 17-25 million people in the world suffer from Alzheimer's disease (AD). The most efficacious and acceptable therapeutic drug clinically are the acetylcholinesterase inhibitors (AChEIs). Yinhuang oral liquid is a Chinese medicine preparation which contains AChEIs according to the literatures. However, no strategy has been presented for rapid screening and identification of AChEIs from Yinhuang oral liquid. To develop a method for rapid screening and identification of AChEIs from Yinhuang oral liquid using ultrafiltration-liquid chromatography-electrospray ionization tandem mass spectrometry (UF-LC-ESI-MS/MS). In this study, UF incubation conditions such as enzyme concentration, incubation time, and incubation temperature were optimized so as to get better screening results. The AChEIs from Yinhuang oral liquid were identified by high-performance liquid chromatography-ESI-MS and the improved Ellman method was used for the AChE inhibitory activity test in vitro . The results showed that Yinhuang oral liquid can inhibit the activity of AChE. We screened and identified seven compounds with potential AChE inhibitory activity from Yinhuang oral liquid, which provided experimental basis for the treatment and prevention of AD. The current technique was used to directly screen the active ingredients with acetylcholinesterase inhibition from complex traditional Chinese medicine, which was simple, rapid, accurate, and suitable for high-throughput screening of AChEI from complex systems. A UF-LC-ESI-MS/MS method for rapid screening and identification of AChEIs from Yinhuang oral liquid was developedSeven compounds were screened and identified with potential AChE inhibitory activity from Yinhuang oral liquidIt provided experimental basis of Yinhuang oral liquid for the treating and preventing AD. Abbreviations used: (AD): Alzheimer's disease; (UF-LC-ESI-MS/MS): ultrafiltration-liquid chromatography-electrospray ionization tandem mass spectrometry; (ACh

  20. Rapid Screening and Characterization of Acetylcholinesterase Inhibitors from Yinhuang Oral Liquid Using Ultrafiltration-liquid Chromatography-electrospray Ionization Tandem Mass Spectrometry

    Science.gov (United States)

    Zhang, Haomin; Guo, Yinan; Meng, Lingwen; Sun, Hui; Yang, Yinping; Gao, Ying; Sun, Jiaming

    2018-01-01

    Background: At present, approximately 17–25 million people in the world suffer from Alzheimer's disease (AD). The most efficacious and acceptable therapeutic drug clinically are the acetylcholinesterase inhibitors (AChEIs). Yinhuang oral liquid is a Chinese medicine preparation which contains AChEIs according to the literatures. However, no strategy has been presented for rapid screening and identification of AChEIs from Yinhuang oral liquid. Objective: To develop a method for rapid screening and identification of AChEIs from Yinhuang oral liquid using ultrafiltration–liquid chromatography–electrospray ionization tandem mass spectrometry (UF-LC-ESI-MS/MS). Materials and Methods: In this study, UF incubation conditions such as enzyme concentration, incubation time, and incubation temperature were optimized so as to get better screening results. The AChEIs from Yinhuang oral liquid were identified by high-performance liquid chromatography-ESI-MS and the improved Ellman method was used for the AChE inhibitory activity test in vitro. Results: The results showed that Yinhuang oral liquid can inhibit the activity of AChE. We screened and identified seven compounds with potential AChE inhibitory activity from Yinhuang oral liquid, which provided experimental basis for the treatment and prevention of AD. Conclusion: The current technique was used to directly screen the active ingredients with acetylcholinesterase inhibition from complex traditional Chinese medicine, which was simple, rapid, accurate, and suitable for high-throughput screening of AChEI from complex systems. SUMMARY A UF-LC-ESI-MS/MS method for rapid screening and identification of AChEIs from Yinhuang oral liquid was developedSeven compounds were screened and identified with potential AChE inhibitory activity from Yinhuang oral liquidIt provided experimental basis of Yinhuang oral liquid for the treating and preventing AD. Abbreviations used: (AD): Alzheimer's disease; (UF

  1. In situ derivatization-ultrasound-assisted dispersive liquid-liquid microextraction for the determination of neurotransmitters in Parkinson's rat brain microdialysates by ultra high performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    He, Yongrui; Zhao, Xian-En; Zhu, Shuyun; Wei, Na; Sun, Jing; Zhou, Yubi; Liu, Shu; Liu, Zhiqiang; Chen, Guang; Suo, Yourui; You, Jinmao

    2016-08-05

    Simultaneous monitoring of several neurotransmitters (NTs) linked to Parkinson's disease (PD) has important scientific significance for PD related pathology, pharmacology and drug screening. A new simple, fast and sensitive analytical method, based on in situ derivatization-ultrasound-assisted dispersive liquid-liquid microextraction (in situ DUADLLME) in a single step, has been proposed for the quantitative determination of catecholamines and their biosynthesis precursors and metabolites in rat brain microdialysates. The method involved the rapid injection of the mixture of low toxic bromobenzene (extractant) and acetonitrile (dispersant), which containing commercial Lissamine rhodamine B sulfonyl chloride (LRSC) as derivatization reagent, into the aqueous phase of sample and buffer, and the following in situ DUADLLME procedure. After centrifugation, 50μL of the sedimented phase (bromobenzene) was directly injected for ultra high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) detection in multiple reaction monitoring (MRM) mode. This interesting combination brought the advantages of speediness, simpleness, low matrix effects and high sensitivity in an effective way. Parameters of in situ DUADLLME and UHPLC-MS/MS conditions were all optimized in detail. The optimum conditions of in situ DUADLLME were found to be 30μL of microdialysates, 150μL of acetonitrile containing LRSC, 50μL of bromobenzene and 800μL of NaHCO3-Na2CO3 buffer (pH 10.5) for 3.0min at 37°C. Under the optimized conditions, good linearity was observed with LODs (S/N>3) and LOQs (S/N>10) of LRSC derivatized-NTs in the range of 0.002-0.004 and 0.007-0.015 nmol/L, respectively. It also brought good precision (3.2-12.8%, peak area CVs%), accuracy (94.2-108.6%), recovery (94.5-105.5%) and stability (3.8-8.1%, peak area CVs%) results. Moreover, LRSC derivatization significantly improved chromatographic resolution and MS detection sensitivity of NTs when compared with the

  2. Validation and application of a high-performance liquid chromatography-tandem mass spectrometric method for simultaneous quantification of lopinavir and ritonavir in human plasma using semi-automated 96-well liquid-liquid extraction.

    Science.gov (United States)

    Wang, Perry G; Wei, Jack S; Kim, Grace; Chang, Min; El-Shourbagy, Tawakol

    2006-10-20

    Kaletra is an important antiretroviral drug, which has been developed by Abbott Laboratories. It is composed of lopinavir (low-pin-a-veer) and ritonavir (ri-toe-na-veer). Both have been proved to be human immunodeficiency virus (HIV) protease inhibitors and have substantially reduced the morbidity and mortality associated with HIV-1 infection. We have developed and validated an assay, using liquid chromatography coupled with atmospheric pressure chemical ionization tandem mass spectrometry (LC/MS/MS), for the routine quantification of lopinavir and ritonavir in human plasma, in which lopinavir and ritonavir can be simultaneously analyzed with high throughput. The sample preparation consisted of liquid-liquid extraction with a mixture of hexane: ethyl acetate (1:1, v/v), using 100 microL of plasma. Chromatographic separation was performed on a Waters Symmetry C(18) column (150 mm x 3.9 mm, particle size 5 microm) with reverse-phase isocratic using mobile phase of 70:30 (v/v) acetonitrile: 2 mM ammonium acetate aqueous solution containing 0.01% formic acid (v/v) at a flow rate of 1.0 mL/min. A Waters symmetry C(18) guard column (20 mm x 3.9 mm, particle size 5 microm) was connected prior to the analytical column, and a guard column back wash was performed to reduce the analytical column contamination using a mixture of tetrahydrofuran (THF), methanol and water (45:45:10, v/v/v). The analytical run was 4 min. The use of a 96-well plate autosampler allowed a batch size up to 73 study samples. A triple-quadrupole mass spectrometer was operated in a positive ion mode and multiple reaction monitoring (MRM) was used for drug quantification. The method was validated over the concentration ranges of 19-5,300 ng/mL for lopinavir and 11-3,100 ng/mL for ritonavir. A-86093 was used as an internal standard (I.S.). The relative standard deviation (RSD) were <6% for both lopinavir and ritonavir. Mean accuracies were between the designed limits (+/-15%). The robust and rapid LC

  3. Matrix effect on the determination of synthetic corticosteroids and diuretics by liquid chromatography-tandem mass spectrometry

    Science.gov (United States)

    Dikunets, M. A.; Appolonova, S. A.; Rodchenkov, G. M.

    2009-04-01

    This work presents a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) procedure for selective and reliable screening of corticosteroids and diuretics in human urine. Sample preparation included the extraction, evaporation of the organic extract under nitrogen, and solution of the dry residue. The extract was analyzed by HPLC combined with tandem mass spectrometry using electro-spraying ionization at atmospheric pressure with negative ion recording. The mass spectra of all compounds were recorded, and the characteristic ions, retention times, and detection limits were determined. The procedure was validated by evaluating the degree of the matrix suppression of ionization, extraction of analytes from human biological liquid, and the selectivity and specificity of determination.

  4. Multiresidue analysis of 47 pesticides in cooked wheat flour and polished rice by liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Lee, Sung Jung; Park, Hyeong Jin; Kim, Wooseong; Jin, Jong Sung; Abd El-Aty, A M; Shim, Jae-Han; Shin, Sung Chul

    2009-04-01

    Liquid chromatography in conjunction with tandem mass spectrometry was used to directly quantify of 47 pesticide residues from cooked wheat flour and polished rice, which are the most widely consumed cereals in the Republic of Korea. The sample clean-up was carried out according to the method established by the Korea Food and Drug Administration. The mobile phase for liquid chromatography separation consisted of water and 5 mm methanolic ammonium formate. Tandem mass spectroscopy experiments were performed in electrospray ionization positive mode and the multiple reaction monitoring mode. The matrix effects estimated for the 47 pesticides had a mean value of 99% and ranged from 45 to 147%. High recoveries (70-140%) and relative standard deviations (flour and polished rice samples. Of the screened pesticide residues, only tricyclazole and fenobucarb were found in polished rice samples. However, no samples contained residues above the MRL established by the Korea Food and Drug Administration.

  5. Identification and quantification of 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid glucuronide (THC-COOH-glu) in hair by ultra-performance liquid chromatography tandem mass spectrometry as a potential hair biomarker of cannabis use.

    Science.gov (United States)

    Pichini, Simona; Marchei, Emilia; Martello, Simona; Gottardi, Massimo; Pellegrini, Manuela; Svaizer, Fiorenza; Lotti, Andrea; Chiarotti, Marcello; Pacifici, Roberta

    2015-04-01

    We developed and validated an ultra-high-pressure liquid chromatography-tandem mass spectrometry method to identify and quantify 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid glucuronide in hair of cannabis consumers. After hair washing with methyl alcohol and diethyl ether and subsequent addition of amiodarone as internal standard hair samples were treated with 500 μl VMA-T M3 buffer reagent for 1 h at 100 °C. After cooling, 10 μl VMA-T M3 extract were injected into chromatographic system. Chromatographic separation was carried out on a reversed phase column using a linear gradient elution with two solvents: 5 mM ammonium formate pH 3.0 (solvent A) and 0.1% formic acid in acetonitrile (solvent B). The flow rate was kept constant at 0.4 ml/min during the analysis. The separated analytes were detected with a triple quadrupole mass spectrometer operated in multiple reaction monitoring mode via positive electrospray ionization. Linear calibration curves were obtained for 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid glucuronide with correlation coefficients (r(2)) of 0.99 and a limit of quantification of 0.25 pg/mg hair. Analytical recovery was between 79.6% and 100.7% and intra- and inter-assay imprecision and inaccuracy were always lower than 15%. Ultra-high-pressure liquid chromatography-tandem mass spectrometry analysis of 20 different hair samples of cannabis consumers disclosed the presence of 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid glucuronide in the range of 0.5-8.6 pg/mg hair. These data provided a good start to consider 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid glucuronide as alternative hair biomarker of cannabis consumption. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  6. Simultaneous quantification of twenty Amadori products in soy sauce using liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Katayama, Hiroshi; Tatemichi, Yuki; Nakajima, Ayako

    2017-08-01

    A liquid chromatography-tandem mass spectrometry method using a pentafluorophenylpropyl-bonded silica column was developed to simultaneously quantify twenty Amadori products (APs), including N-(1-Deoxy-d-fructosyl-1-yl)-l-isoleucine (Fru-Ile) and N-(1-Deoxy-d-fructosyl-1-yl)-l-leucine (Fru-Leu), in soy sauce, without the need for an ion-pairing reagent or sample derivatization. The method was applied to six types of soy sauce, to determine the total AP levels and the levels of individual APs. The level of total APs widely varied between the eight samples, from 358mg/L to 24347mg/L. The concentrations of N-ε-(1-deoxy-d-fructosyl-1-yl)-l-lysine (Fru-Lys) and N-(1-deoxy-d-fructosyl-1-yl)-l-pyroglutamic acid (Fru-pGlu) were the highest among the APs and the level of Fru-pGlu was similar to that of Fru-Lys. Furthermore, fermentation periods of up to six months greatly influenced AP levels in soy sauce but the levels remained constant thereafter. Thermal treatment of soy sauce had little effect on AP levels. Copyright © 2017. Published by Elsevier Ltd.

  7. Determination of levofloxacin in human serum using liquid chromatography tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Samiksha Ghimire

    2018-01-01

    Full Text Available A rapid liquid chromatography tandem-mass spectrometry method was developed for the determination of levofloxacin and its metabolite (desmethyl-levofloxacin in human serum. Sample preparation was done using protein precipitation technique. Our method had a run time of 2.5 min and retention times of 1.6 min for all analytes. The standard curves were linear within the concentration range of 0.10 to 5.00 mg/L for levofloxacin and 0.10 to 4.99 mg/L for desmethyl- levofloxacin; a correlation coefficient (R2 of 0.999 and 0.998 respectively. The lower limit of quantification for both analytes was 0.10 mg/L. Within-day precision ranged from 1.4% and 2.4% for levofloxacin, 1.5% to 5% for desmethyl-levofloxacin and between-day precision ranged from 3.6% to 4.1% for levofloxacin and 0.0% to 3.3% for desmethyl-levofloxacin; whereas, accuracy ranged from 0.1% to 12.7% for levofloxacin and 0.2% to 15.6% for desmethyl-levofloxacin. This method could be a useful asset for routine therapeutic drug monitoring of levofloxacin in multi-drug resistant tuberculosis patients.

  8. Multi-detection of preservatives in cheeses by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Fuselli, Fabio; Guarino, Chiara; La Mantia, Alessandro; Longo, Lucia; Faberi, Angelo; Marianella, Rosa Maria

    2012-10-01

    The incorrect use of preservatives in cheeses may compromise food safety and damage consumers. According to the law, more than one preservative may be contemporarily used in cheeses. So a method for their contemporary detection may be useful for both manufacturers and control agencies quality control. In this research a liquid chromatography-tandem mass spectrometric with electrospray ionization method for the multi-determination of seven preservatives (benzoic acid, citric acid, hexamethylenetetramine, lysozyme, natamycin, nisin and sorbic acid) in cheese was developed. The preservatives were contemporarily extracted from cheese by a single procedure, and analyzed by RP-LC/ESI-MS/MS (Ion Trap) in positive ionization mode, with single reaction monitoring (SRM) acquisition. Three sample types (hard, pasta filata and fresh cheese) were used for method evaluation. Recoveries were mostly higher than 90%; MDLs ranged from 0.02 to 0.26 mgkg(-1), and MQLs were included between 0.07 and 0.88 mgkg(-1). Due to matrix effect, quantitation was performed by referring to a matrix matched calibration curve, for each cheese typology. This method was also applied to commercial cheese samples, with good results. It appears fast, reliable and suitable for both screening and confirmation of the presence and quantitation of the preservatives in a single, multi-detection analysis. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. Proteomic analysis of Taenia ovis metacestodes by high performance liquid chromatography-coupled tandem mass spectrometry.

    Science.gov (United States)

    Zheng, Yadong

    2017-03-15

    Taenia ovis metacestodes reside in the muscle of sheep and goats, and may cause great economic loss due to condemnation of carcasses if not effectively controlled. Although advances have been made in the control of T. ovis infection, our knowledge of T. ovis biology is limited. Herein the protein profiling of T. ovis metacestodes was determined by liquid chromatography-linked tandem mass spectrometry. A total of 966 proteins were identified and 25.1% (188/748) were annotated to be associated with metabolic pathways. Consistently, GO analysis returned a metabolic process (16.27%) as one of two main biological process terms. Moreover, it was found that 24 proteins, including very low-density lipoprotein receptor, enolase, paramyosin and endophilin B1, were abundant in T. ovis metacestodes. These proteins may be associated with motility, metabolism, signaling, stress, drug resistance and immune responses. Furthermore, comparative analysis of 5 cestodes revealed the presence of Taenia-specific enolases. These data provide clues for better understanding of T. ovis biology, which is informative for effective control of infection. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Determination of the Thyreostats in Animal Feeding Stuffs Using Liquid Chromatography-Tandem Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Woźniak Barbara

    2014-10-01

    Full Text Available A rapid liquid chromatography tandem mass spectrometry method was developed and validated to detect and confirm five thyreostatic drugs: tapazole, thiouracil, methylthiouracil, propylthiouracil, and phenylthiouracil in animal feeding stuff samples. Thyreostats were extracted from feed with methanol, and then degreasing of the extract with petroleum ether was performed, followed by the derivatisation of the compounds with 3-iodobenzylbromide in basic medium (pH 8.0. The derivatives were extracted with diethyl ether and analysed by gradient elution on a Poroshell 120-EC C18 column with triple quadrupole MS detection with turbo spray source in positive ionisation mode. The method was validated in accordance with the Commission Decision 2002/657/EC. For validation level of 10 ļig kg-1, the recovery ranged from 82% to 97.5% for all examined compounds. The repeatability and reproducibility did not exceed the limit of 20% for all analytes. The linearity was good for all thyreostats in the whole range of tested concentrations, as proved by the correlation coefficients greater than 0.99. The decision limits (CCa ranged from 1.63 ļig kg-1 to 3.95 ļig kg-1, whereas the detection capabilities (CCß ranged from 2.74 ļig kg-1 to 6.73 ļig kg-1. The developed analysis is sensitive and robust, and therefore useful for quantification and confirmation of thyreostats in residue control programme.

  11. Proteomic profiling of human pleural effusion using two-dimensional nano liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Tyan, Yu-Chang; Wu, Hsin-Yi; Lai, Wu-Wei; Su, Wu-Chou; Liao, Pao-Chi

    2005-01-01

    Pleural effusion, an accumulation of pleural fluid, contains proteins originated from plasma filtrate and, especially when tissues are damaged, parenchyma interstitial spaces of lungs and/or other organs. This study details protein profiles in human pleural effusion from 43 lung adenocarcinoma patients by a two-dimensional nano-high performance liquid chromatography electrospray ionization tandem mass spectrometry (2D nano-HPLC-ESI-MS/MS) system. The experimental results revealed the identification of 1415 unique proteins from human pleural effusion. Among these 124 proteins identified with higher confidence levels, some proteins have not been reported in plasma and may represent proteins specifically present in pleural effusion. These proteins are valuable for mass identification of differentially expressed proteins involved in proteomics database and screening biomarker to further study in human lung adenocarcinoma. The significance of the use of proteomics analysis of human pleural fluid for the search of new lung cancer marker proteins, and for their simultaneous display and analysis in patients suffering from lung disorders has been examined.

  12. Multiclass analysis of antibiotic residues in honey by ultraperformance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Vidal, Jose Luis Martínez; Aguilera-Luiz, María Del Mar; Romero-González, Roberto; Frenich, Antonia Garrido

    2009-03-11

    A method has been developed and validated for the simultaneous analysis of different veterinary drug residues (macrolides, tetracyclines, quinolones, and sulfonamides) in honey. Honey samples were dissolved with Na(2)EDTA, and veterinary residues were extracted from the supernatant by solid-phase extraction (SPE), using OASIS HLB cartridges. The separation and determination was carried out by ultraperformance liquid chromatography coupled to tandem mass spectrometry (UPLC-MS/MS), using an electrospay ionization source (ESI) in positive mode. Data acquisition under MS/MS was achieved by applying multiple reaction monitoring (MRM) of two ion transitions per compound to provide a high degree of sensitivity and specificity. The method was validated, and mean recoveries were evaluated at three concentration levels (10, 50, and 100 microg/kg), ranging from 70 to 120% except for doxycycline, erythromycin, and tylmicosin with recovery higher than 50% at the three levels assayed. Relative standard deviations (RSDs) of the recoveries were less than 20% within the intraday precision and less than 25% within the interday precision. The limits of quantification (LOQs) were always lower than 4 microg/kg. The developed procedure was applied to 16 honey samples, and erythromycin, sarafloxacin, and tylosin were found in a few samples.

  13. Recent advances of liquid chromatography-(tandem) mass spectrometry in clinical and forensic toxicology - An update.

    Science.gov (United States)

    Remane, Daniela; Wissenbach, Dirk K; Peters, Frank T

    2016-09-01

    Liquid chromatography (LC) coupled to mass spectrometry (MS) or tandem mass spectrometry (MS/MS) is a well-established and widely used technique in clinical and forensic toxicology as well as doping control especially for quantitative analysis. In recent years, many applications for so-called multi-target screening and/or quantification of drugs, poisons, and or their metabolites in biological matrices have been developed. Such methods have proven particularly useful for analysis of so-called new psychoactive substances that have appeared on recreational drug markets throughout the world. Moreover, the evolvement of high resolution MS techniques and the development of data-independent detection modes have opened new possibilities for applications of LC-(MS/MS) in systematic toxicological screening analysis in the so called general unknown setting. The present paper will provide an overview and discuss these recent developments focusing on the literature published after 2010. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  14. [Determination of gossypol in edible vegetable oil with high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Zhang, Wenhua; Huang, Chaoqun; Xie, Wen; Shen, Li

    2014-06-01

    A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the determination of gossypol in edible vegetable oil. The sample was extracted with ethyl alcohol by vortex-excited oscillation. The extract was cleaned up by 0.22 microm filter membrane and centrifuged for 5 min at 4 000 r/min after standing in a fridge at 4 degrees C for 30 min. The compound was separated on a C18 column (100 mm x 2.1 mm, 3.5 microm) with acetonitrile and 1% (v/v) formic acid aqueous solution as mobile phase. The detection of gossypol was carried out by LC-MS/MS with positive electrospray ionization under multiple reaction monitoring (MRM) mode using external standard method. The limits of quantification (S/N > 10) of gossypol in edible vegetable oil was 1 mg/kg. The recoveries were from 87.4% to 100% at the spiked levels of 1, 2, 200 mg/kg of gossypol in edible vegetable oil with the relative standard deviations (RSDs) between 3.9% and 12.2%. The method, with high sensitivity, good precision and high recovery, was suitable for the confirmation and quantification of gossypol residue in edible vegetable oil.

  15. Characterization of the limonene oxidation products with liquid chromatography coupled to the tandem mass spectrometry

    Science.gov (United States)

    Witkowski, Bartłomiej; Gierczak, Tomasz

    2017-04-01

    Composition of the secondary organic aerosol (SOA) generated during ozonolysis of limonene was investigated with liquid chromatography coupled to the negative electrospray ionization (ESI), quadrupole tandem mass spectrometry (MS/MS) as well as high resolution Time-of-Flight mass spectrometry. Aerosol was generated in the flow-tube reactor. HR-MS/MS analysis allowed for proposing structures for the several up-to-date unknown limonene oxidation products. In addition to the low MW limonene oxidation products, significant quantities of oligomers characterized by elemental compositions: C19H30O5, C18H28O6, C19H28O7, C19H30O7 and C20H34O9 were detected in the SOA samples. It was concluded that these compounds are most likely esters, aldol reaction products and/or hemiacetals. In addition to detailed study of the limonene oxidation products, the reaction time as well as initial ozone concentration impact on the limonene SOA composition was investigated. The relative intensities of the two esters of the limonic acid and 7-hydroxy limononic acid increased as a result of lowering the initial ozone concentration and shortening the reaction time, indicating that esterification may be an important oligomerization pathway during limonene SOA formation.

  16. Residue analysis of orthosulfamuron herbicide in fatty rice using liquid chromatography–tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Young-Jun Lee

    2015-05-01

    Full Text Available In the present study, orthosulfamuron residues were extracted from fatty (unpolished rice and rice straw using a modified QuEChERS method and analyzed using liquid chromatography–tandem mass spectrometry. The matrix-matched calibration was linear over the concentration ranges of 0.01–2.0 mg/kg with determination coefficient (R2 ⩾ 0.997. The recovery rates at two fortification levels (0.1 and 0.5 mg/kg were satisfactory and ranged between 88.1% and 100.6%, with relative standard deviation (RSD <8%. The limit of quantitation, 0.03 mg/kg, was lower than the maximum residue limit, 0.05 mg/kg, set by the Ministry of Food and Drug Safety in the Republic of Korea. The developed method was applied successfully to field samples harvested at 116 days and none of the samples were positive for the residue.

  17. Quantitation of 5-Methyltetrahydrofolate in Cerebrospinal Fluid Using Liquid Chromatography-Electrospray Tandem Mass Spectrometry.

    Science.gov (United States)

    Arning, Erland; Bottiglieri, Teodoro

    2016-01-01

    We describe a simple stable isotope dilution method for accurate and precise measurement of cerebrospinal fluid (CSF) 5-methyltetrahydrofolate (5-MTHF) as a clinical diagnostic test. 5-MTHF is the main biologically active form of folic acid and is involved in regulation of homocysteine and DNA synthesis. Measurement of 5-MTHF in CSF provides diagnostic information regarding diseases affecting folate metabolism within the central nervous system, in particular inborn errors of folate metabolism. Determination of 5-MTHF in CSF (50 μL) was performed utilizing high performance liquid chromatography coupled with electrospray positive ionization tandem mass spectrometry (HPLC-ESI-MS/MS). 5-MTHF in CSF is determined by a 1:2 dilution with internal standard (5-MTHF-(13)C5) and injected directly onto the HPLC-ESI-MS/MS system. Each assay is quantified using a five-point standard curve (25-400 nM) and has an analytical measurement range of 3-1000 nM.

  18. Measurement of tamsulosin in human serum by liquid chromatography–tandem mass spectrometry☆

    Science.gov (United States)

    Upreti, Rita; Homer, Natalie Z.M.; Naredo, Gregorio; Cobice, Diego F.; Hughes, Katherine A.; Stewart, Laurence H.; Walker, Brian R.; Andrew, Ruth

    2013-01-01

    A simple, sensitive and robust method to extract tamsulosin from human serum, and quantify by liquid chromatography–tandem mass spectrometry (LC–MS/MS) was developed and validated and is applicable as a measure of compliance in clinical research. Tamsulosin was extracted from human serum (100 μL) via liquid–liquid extraction with methyl tert-butyl ether (2 mL) following dilution with 0.1 M ammonium hydroxide (100 μL), achieving 99.9% analyte recovery. Internal standard, d9-finasteride, was synthesised in-house. Analyte and internal standard were separated on an Ascentis® Express C18 (100 mm × 3 mm, 2.7 μm) column using a gradient elution with mobile phases methanol and 2 mM aqueous ammonium acetate (5:95, v/v). Total run-time was 6 min. Tamsulosin was quantified using a triple quadrupole mass spectrometer operated in multi-reaction-monitoring (MRM) mode using positive electrospray ionisation. Mass transitions monitored for quantitation were: tamsulosin m/z 409 → 228 and d9-finasteride m/z 382 → 318, with the structural formulae of ions confirmed by Fourier transform ion cyclotron resonance mass spectrometry (within 10 ppm). The limit of quantitation was 0.2 ng/mL, and the method was validated in the linear range 0.2–50 ng/mL with acceptable inter- and intra-assay precision and accuracy and stability suitable for routine laboratory practice. The method was successfully applied to samples taken from research volunteers in a clinical study of benign prostatic hyperplasia. PMID:23743242

  19. A New High-Performance Liquid Chromatographic Method for the Determination and Distribution of Linalool in Michelia alba

    Directory of Open Access Journals (Sweden)

    Hua-Bin Li

    2010-07-01

    Full Text Available A new high-performance liquid chromatographic method with photodiode array detection was established for the determination of linalool in the plant Michelia alba. Linalool was extracted from the plant sample with the aid of ultrasound, and was analyzed on a Waters RP C18 column (4.6 × 150 mm, 5 μm using an acetonitrile and water (55:45, v/v mobile phase at a flow rate of 1.0 mL/min. The column temperature was set at 25 ºC, and the detection wavelength was 210 nm. The linear range of the method was 5–200 μg/mL with a correlation coefficient of 0.9975. The recovery was 92–112%, and the relative standard deviation was 1.85% (n = 9. The present method has been used to study the distribution of linalool in the plant Michelia alba. The plant samples include flowers, leaves and tender twigs. Furthermore, leaves included samples in their tender, grown-up and fallen phases, and flowers included samples in their juvenile, middle and whitening phases. The concentrations of linalool in different parts of the plant were 0.21–0.65%, 1.63–4.89% and 0.43% for leaves, flowers and tender twigs, respectively. The results showed that all the plant materials contained relative high concentration of linalool, and juvenile phase flowers contained the highest concentration of linalool. Notably, the fallen leaves also contained high concentrations of linalool, which could be a potential resource of this compound. The results obtained are very helpful for the potential full utilization of this plant.

  20. Supramolecular solvent-based extraction of benzimidazolic fungicides from natural waters prior to their liquid chromatographic/fluorimetric determination.

    Science.gov (United States)

    Moral, Antonia; Sicilia, María Dolores; Rubio, Soledad

    2009-05-01

    A supramolecular solvent made up of vesicles of decanoic acid in the nano- and microscale regimes dispersed in a continuous aqueous phase is proposed for the extraction/preconcentration of benzimidazolic fungicides (BFs) from river and underground water samples prior to their determination by liquid chromatography (LC)/fluorimetry. The solvent is produced from the coacervation of decanoic acid aqueous vesicles by the action of tetrabutylammonium (Bu(4)N(+)). Carbendazim (CB), thiabendazole (TB) and fuberidazole (FB) are extracted on the basis of hydrophobic and pi-cation interactions and the formation of hydrogen bonds. The extraction provides high preconcentration factors (160 for CB and 190 for TB and FB), requires a short time (the procedure takes less than 20 min and several samples can be simultaneously processed) and a low sample volume (20 mL), and avoids the use of toxic organic solvents. Because of the absence of matrix interferences and the low viscosity of the extracts, these can be directly injected into the chromatographic system without the need of cleaning-up or diluting them. Recoveries are not influenced by the presence of salt concentrations up to 1 M. The proposed method provides detection limits for the determination of CB, TB and FB in natural waters of 32, 4 and 0.1 ng L(-1), respectively, and a precision, expressed as relative standard deviation (n=11) of 5.5% for CB (100 ng L(-1)), 4.0% for TB (80 ng L(-1)) and 2.5% for FB (30 ng L(-1)). Recoveries obtained by applying this approach to the analysis of river and underground water samples fortified at the ng L(-1) level are in the intervals 75-83, 95-102 and 97-101% for CB, TB and FB, respectively.

  1. An ecofriendly green liquid chromatographic method for simultaneous determination of nicotinamide and clindamycin phosphate in pharmaceutical gel for acne treatment

    Directory of Open Access Journals (Sweden)

    Fawzia Ibrahim

    2017-07-01

    Full Text Available A new green micellar liquid chromatographic method was developed and validated for the quantitative estimation of nicotinamide (NICO and clindamycin phosphate (CLD in bulk and pharmaceutical gel formulation. The analytes are well resolved in less than 6.0 minutes using micellar mobile phase consisting of 0.10M sodium dodecyl sulfate (SDS, 0.3% triethylamine, and 10% 2-propanol in 0.02M orthophosphoric acid at pH 3.0, running through an Eclipse XDB-C8 column (150 mm×4.6 mm, 5 μm particle size with flow rate 1.0 mL/min. The effluent was monitored with diode array detection at 210 nm. The retention times of NICO and CLD were 3.8 minutes and 5.6 minutes, respectively. The method was validated according to the International Conference on Harmonisation (ICH guidelines in terms of linearity, limit of detection, limit of quantification, accuracy, precision, robustness, and specificity to prove its reliability. Linear correlation was achieved by plotting the peak area of each drug against its concentration. It was found to be rectilinear in the ranges of 1.0–40.0 μg/mL and 0.5–15.0 μg/mL with limits of detection of 0.06 μg/mL and 0.03 μg/mL and limits of quantification of 0.19 μg/mL and 0.09 μg/mL for NICO and CLD, respectively. The method was successfully implemented for the simultaneous determination of the analytes in their bulk powder and combined gel formulation with high % recoveries. The ease of sample treatment facilitates and greatly expedites the treatment with reduced cost and improved accuracy of the procedure.

  2. Reductive amination of glutaraldehyde 2,4-dinitrophenylhydrazone using 2-picoline borane and high-performance liquid chromatographic analysis.

    Science.gov (United States)

    Uchiyama, Shigehisa; Sakamoto, Hironari; Ohno, Akiko; Inaba, Yohei; Nakagome, Hideki; Kunugita, Naoki

    2012-09-21

    A typical method for the measurement of glutaraldehyde (GLA) employs 2,4-dinitrophenylhydrazine (DNPH) to form GLA-DNPhydrazone derivatives. However, this method is subject to analytical errors because GLA-DNPhydrazone is a quaternary bis-derivative and forms three geometric isomers (E-E, E-Z and Z-Z) as a result of the two C[double bond, length as m-dash]N double bonds. To overcome this issue, a method for transforming the C[double bond, length as m-dash]N double bond into a C-N single bond, using reductive amination of DNPhydrazone derivatives, has been applied. The amination reaction of GLA-DNPhydrazones with 2-picoline borane is accelerated with catalytic amounts of acid and is completed within 10 minutes in the presence of 100 mmol L(-1) phosphoric acid. Reduction of GLA-DNPhydrazone by 2-picoline borane is unique and results in the formation of N-(2,4-dinitrophenyl)-1-piperidinamine (DNPPA). NMR and LC-APCI-MS data confirmed the product identification. DNPPA is very stable and did not change when stored for at least four weeks at room temperature. DNPPA has excellent solubility of 14.6 g L(-1) at 20 °C in acetonitrile. The absorption maximum wavelength and the molar absorptivity of DNPPA were 351 nm and 4.2 × 10(4) L mol(-1) cm(-1) respectively. Complete separation between the reduced forms of C1-C10 aldehyde DNPhydrazones, including DNPPA, can be achieved by operating the reversed-phase high-performance liquid chromatograph at 351 nm in gradient mode using a C18 amide column. The reductive amination method for GLA overcomes analytical errors caused by E-E, E-Z and Z-Z geometrical isomers.

  3. Characterization of bisphenol A metabolites produced by Portulaca oleracea cv. by liquid chromatography coupled with tandem mass spectrometry.

    Science.gov (United States)

    Watanabe, Ippei; Harada, Kazuo; Matsui, Takeshi; Miyasaka, Hitoshi; Okuhata, Hiroshi; Tanaka, Satoshi; Nakayama, Hideki; Kato, Ko; Bamba, Takeshi; Hirata, Kazumasa

    2012-01-01

    The garden plant portulaca (Portulaca oleracea cv.) efficiently removes bisphenol A (BPA), an endocrine-disrupting chemical, from a hydroponic solution, but the molecular mechanisms underlying BPA metabolism by portulaca remain unclear. In this study, BPA metabolites converted by portulaca were analyzed by liquid chromatography coupled with tandem mass spectrometry. We observed the hydroxylation of BPA and the oxidization of it to quinone. Polyphenol oxidases are likely to contribute to BPA degradation by portulaca.

  4. Quantitative analysis of cocaine and its metabolites in whole blood and urine by high-performance liquid chromatography coupled with tandem mass spectrometry.

    Science.gov (United States)

    Johansen, Sys Stybe; Bhatia, Helle Merete

    2007-06-01

    In forensic toxicology it is important to have specific and sensitive analysis for quantification of illicit drugs in biological matrices. This paper describes a quantitative method for determination of cocaine and its major metabolites (ecgonine methyl ester, benzoylecgonine, norcocaine and ethylene cocaine) in whole blood and urine by liquid chromatography coupled with tandem mass spectrometry LC/MS/MS. The sample pre-treatment (0.20 g) consisted of acid precipitation, followed by centrifugation and solid phase extraction of supernatant using mixed mode sorbent columns (SPEC MP1 Ansys Diag. Inc.). Chromatographic separation was performed at 30 degrees C on a reverse phase Zorbax C18 column with a gradient system consisting of formic acid, water and acetonitrile. The analysis was performed by positive electrospray ionisation with a triple quadropole mass spectrometer operating in multiple reaction monitoring (MRM) mode. Two MRM transitions of each analyte were established and identification criteria were set up based on the retention time and the ion ratio. The quantification was performed using deuterated internal analytes of cocaine, benzoylecgonine and ecgonine methyl ester. The calibration curves of extracted standards were linear over a working range of 0.001-2.00 mg/kg whole blood for all analytes. The limit of quantification was 0.008 mg/kg; the interday precision (measured by relative standard deviation-%RSD) was less than 10% and the accuracy (BIAS) less than 12% for all analytes in whole blood. Urine samples were estimated semi-quantitatively at a cut-off level of 0.15 mg/kg with an interday precision of 15%. A liquid chromatography mass spectrometric (LC/MS/MS) method has been developed for confirmation and quantification of cocaine and its metabolites (ecgonine methyl ester, benzoylecgonine, norcocaine and ethylene cocaine) in whole blood and semi-quantitative in urine. The method is specific and sensitive and offers thereby an excellent alternative to

  5. Selective quantitation of the neurotoxin BMAA by use of hydrophilic-interaction liquid chromatography-differential mobility spectrometry-tandem mass spectrometry (HILIC-DMS-MS/MS).

    Science.gov (United States)

    Beach, Daniel G; Kerrin, Elliott S; Quilliam, Michael A

    2015-11-01

    The neurotoxin β-N-methylamino-L-alanine (BMAA) has been reported in cyanobacteria and shellfish, raising concerns about widespread human exposure. However, inconsistent results for BMAA analysis have led to controversy. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is the most appropriate method for analysis of BMAA, but the risk of interference from isomers, other sample components, and the electrospray background is still present. We have investigated differential mobility spectrometry (DMS) as an ion filter to improve selectivity in the hydrophilic interaction liquid chromatographic (HILIC)-MS/MS determination of BMAA. We obtained standards for two BMAA isomers not previously analyzed by HILIC-MS, β-amino-N-methylalanine and 3,4-diaminobutanoic acid, and the typically used 2,4-diaminobutanoic acid and N-(2-aminoethyl)glycine. DMS separation of BMAA from these isomers was achieved and optimized conditions were used to develop a sensitive and highly selective multidimensional HILIC-DMS-MS/MS method. This work revealed current technical limitations of DMS for trace quantitation, and practical solutions were implemented. Accurate control of low levels of DMS carrier gas modifier was essential, but required external metering. The linearity of our optimized method was excellent from 0.01 to 6 μmol L(-1). The instrumental LOD was 0.4 pg BMAA injected on-column and the estimated method LOD was 20 ng g(-1) dry weight for BMAA in sample matrix. The method was used to analyze cycad plant tissue, a cyanobacterial reference material, and mussel tissues, by use of isotope-dilution quantitation with deuterated BMAA. This confirmed the presence of BMAA and several of its isomers in cycad and mussel tissues, including commercially available mussel tissue reference materials certified for other biotoxins. Graphical Abstract Differential Mobility Spectrometry is used to increases the selectivity of BMAA analysis by HILIC-MS/MS.

  6. EPA CRL MS014: Analysis of Aldicarb, Bromadiolone, Carbofuran, Oxamyl and Methomyl in Water by Multiple Reaction Monitoring Liquid Chromatography / Tandem Mass Spectrometry (LC/MS/MS)

    Science.gov (United States)

    Method MS014 describes procedures for solvent extraction of aldicarb, bromadiolone, carbofuran, oxamyl and methomyl from water samples, followed by analysis using liquid chromatography tandem mass spectrometry (LC-MS-MS).

  7. Determination of a metabolite of nifursol in foodstuffs of animal origin by liquid-liquid extraction and liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Wang, Chuanxian; Qu, Li; Liu, Xia; Zhao, Chaomin; Zhao, Fengjuan; Huang, Fuzhen; Zhu, Zhenou; Han, Chao

    2017-02-01

    An analytical method has been developed for the detection of a metabolite of nifursol, 3,5-dinitrosalicylic acid hydrazide, in foodstuffs of animal origin (chicken liver, pork liver, lobster, shrimp, eel, sausage, and honey). The method combines liquid chromatography and tandem mass spectrometry with liquid-liquid extraction. Samples were hydrolyzed with hydrochloric acid and derivatized with 2-nitrobenzaldehyde at 37°C for 16 h. The solutions of derivatives were adjusted to pH 7.0-7.5, and the metabolite was extracted with ethyl acetate. 3,5-Dinitrosalicylic acid hydrazide determination was performed in the negative electrospray ionization method. Both isotope-labeled internal standard and matrix-matched calibration solutions were used to correct the matrix effects. Limits of quantification were 0.5 μg/kg for all samples. The average recoveries, measured at three concentration levels (0.5, 2.0, and 10 μg/kg) were in the range of 75.8-108.4% with relative standard deviations below 9.8%. The developed method exhibits a high sensitivity and selectivity for the routine determination and confirmation of the presence of a metabolite of nifursol in foodstuffs of animal origin. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Dispersive Liquid-Liquid Microextraction Combined with Ultrahigh Performance Liquid Chromatography/Tandem Mass Spectrometry for Determination of Organophosphate Esters in Aqueous Samples

    Directory of Open Access Journals (Sweden)

    Haiying Luo

    2014-01-01

    Full Text Available A new technique was established to identify eight organophosphate esters (OPEs in this work. It utilised dispersive liquid-liquid microextraction in combination with ultrahigh performance liquid chromatography/tandem mass spectrometry. The type and volume of extraction solvents, dispersion agent, and amount of NaCl were optimized. The target analytes were detected in the range of 1.0–200 µg/L with correlation coefficients ranging from 0.9982 to 0.9998, and the detection limits of the analytes were ranged from 0.02 to 0.07 µg/L (S/N=3. The feasibility of this method was demonstrated by identifying OPEs in aqueous samples that exhibited spiked recoveries, which ranged between 48.7% and 58.3% for triethyl phosphate (TEP as well as between 85.9% and 113% for the other OPEs. The precision was ranged from 3.2% to 9.3% (n=6, and the interprecision was ranged from 2.6% to 12.3% (n=5. Only 2 of the 12 selected samples were tested to be positive for OPEs, and the total concentrations of OPEs in them were 1.1 and 1.6 µg/L, respectively. This method was confirmed to be simple, fast, and accurate for identifying OPEs in aqueous samples.

  9. Determination of Fusarium toxins in functional vegetable milks applying salting-out-assisted liquid-liquid extraction combined with ultra-high-performance liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Hamed, Ahmed M; Arroyo-Manzanares, Natalia; García-Campaña, Ana M; Gámiz-Gracia, Laura

    2017-11-01

    Vegetable milks are considered as functional foods due to their physiological benefits. Although the consumption of these products has significantly increased, they have received little attention in legislation with regard to contaminants. However, they may contain mycotoxins resulting from the use of contaminated raw materials. In this work, ultra-high-performance liquid chromatography tandem mass spectrometry has been proposed for the determination of the most relevant Fusarium toxins (fumonisin B 1 and B 2 , HT-2 and T-2 toxins, zearalenone, deoxynivalenol and fusarenon-X) in different functional beverages based on cereals, legumes and seeds. Sample treatment consisted of a simple salting-out-assisted liquid-liquid extraction with no further clean-up. The method provided limits of quantification between 3.2 and 57.7 µg L -1 , recoveries above 80% and precision with RSD lower than 12%. The method was also applied for studying the occurrence of these mycotoxins in market samples of vegetable functional beverages and deoxynivalenol was found in three oat-based commercial drinks.

  10. Fast quantification of short chain fatty acids and ketone bodies by liquid chromatography-tandem mass spectrometry after facile derivatization coupled with liquid-liquid extraction.

    Science.gov (United States)

    Zeng, Mingfei; Cao, Huachuan

    2018-04-15

    Short chain fatty acids (SCFA) and ketone bodies recently emerged as important physiological relevant metabolites because of their association with microbiota, immunology, obesity and other metabolic states. They were commonly analyzed by GC-MS with long run time and laborious sample preparation. In this study we developed a novel LC-MS/MS method using fast derivatization coupled with liquid-liquid extraction to detect SCFA and ketone bodies in plasma and feces. Several different derivatization reagents were evaluated to compare the efficiency, the sensitivity and chromatographic separation of structural isomers. O‑benzylhydroxylamine was selected for its superior overall performance in reaction time and isomeric separation that allowed the measurement of each SCFAs and ketone bodies free from interferences. The derivatization procedure is facile and reproducible in aqueous-organic medium, which abolished the evaporation procedure hampering the analysis of volatile short chain acids. Enhancement in sensitivity remarkably improved the detection limit of SCFA and ketone bodies to sub-fmol level. This novel method was applied to quantify these metabolites in fecal and plasma samples from lean and DIO mouse. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Rapid determination of some beta-blockers in complicated matrices by tandem dispersive liquid-liquid microextraction followed by high performance liquid chromatography.

    Science.gov (United States)

    Hemmati, Maryam; Asghari, Alireza; Bazregar, Mohammad; Rajabi, Maryam

    2016-11-01

    In this research work, an efficient tandem dispersive liquid-liquid microextraction (TDLLME) procedure coupled with high performance liquid chromatography-ultraviolet detection (HPLC-UV) was successfully applied for the determination of beta-blockers in human plasma and pharmaceutical wastewater samples. High clean-up and preconcentration factor are easily and rapidly feasible via this novel, cheap, and safe microextraction method, leading to high quality experimental data. It consists of two sequential dispersive liquid-liquid microextraction methods, accomplished via air/ultrasonic agitation and air agitation, respectively. In order to enrich the optimal values for the mentioned procedures, the Box-Behnken design (BBD) combined with the desirability function (DF) was used. The optimum values were found to be 11.0 % (w/v) of the salt amount, an initial pH value of 12.0, 103 μL of organic extractant phase, and 45 μL of aqueous extractant phase with pH value of 2.0, resulted in reasonable recovery percentages with a logical desirability. Under optimal experimental conditions, good linear ranges (3-2000 ng mL -1 for metoprolol and 2.5-2500 ng mL -1 for propranolol with the correlation of determinations (R 2 s) higher than 0.99) and low limits of detection (0.8 and 1.0 ng mL -1 for propranolol and metoprolol, respectively) were obtainable. Also, TDLLME-HPLC-UV provided good proper repeatabilities (relative standard deviations (RSDs) below 5.7 %, n = 3) and high enrichment factors (EFs) of 75-100. Graphical abstract TDLLME of beta-blockers from complicated matrices.

  12. Characterizing the selectivity of stationary phases and organic modifiers in reversed-phase high-performance liquid chromatographic systems by a general solvation equation using gradient elution.

    Science.gov (United States)

    Du, C M; Valko, K; Bevan, C; Reynolds, D; Abraham, M H

    2000-11-01

    Retention data for a set of 69 compounds using rapid gradient elution are obtained on a wide range of reversed-phase stationary phases and organic modifiers. The chromatographic stationary phases studied are Inertsil (IN)-ODS, pentafluorophenyl, fluoro-octyl, n-propylcyano, Polymer (PLRP-S 100), and hexylphenyl. The organic solvent modifiers are 2,2,2-trifluoroethanol (TFE); 1,1,1,3,3,3-hexafluoropropan-2-ol (HFIP); isopropanol; methanol (MeOH); acetonitrile (AcN); tetrahydrofuran; 1,4-dioxane; N,N-dimethylformamide; and mixed solvents of dimethylsulfoxide (DMSO) with AcN and DMSO with MeOH (1:1). A total of 25 chromatographic systems are analyzed using a solvation equation. In general, most of the systems give reasonable statistics. The selectivity of the reversed phase-high-performance liquid chromatographic (HPLC) systems with respect to the solute's dipolarity-polarity, hydrogen-bond acidity, and basicity are reflected in correspondingly large coefficients in the solvation equation. We wanted to find the most orthogonal HPLC systems, showing the highest possible selectivity difference in order to derive molecular descriptors using the gradient retention times of a compound. We selected eight chromatographic systems that have a large range of coefficients of interest (s, a, and b) similar to those found in water-solvent partitions used previously to derive molecular descriptors. The systems selected are IN-ODS phases with AcN, MeOH, TFE, and HFIP as mobile phase, PLRP-S 100 phase with AcN, propylcyano phase with AcN and MeOH, and fluorooctyl phase with TFE. Using the retention data obtained for a compound in the selected chromatographic systems, we can estimate the molecular descriptors with the faster and simpler gradient elution method.

  13. Speciation of eight arsenic compounds in human urine by high performance liquid chromatography with inductively coupled plasma mass spectrometric detection using antimonate for internal chromatographic standardization

    DEFF Research Database (Denmark)

    Larsen, Erik Huusfeldt; Pritzl, G.; Hansen, S. H.

    1993-01-01

    Four anionic and four cationic arsenic compounds in urine were separated by anion- and cation-exchange high-performance liquid chromatography and detected by inductively coupled plasma mass spectrometry (ICP-MS) at m/z 75. The species were the anions arsenite, arsenate, monomethylarsonate...... and dimethylarsinate and the cations arsenobetaine, trimethylarsine oxide, arsenocholine and the tetramethylarsonium ion. Hexahydroxyantimonate(III) was co-chromatographed with the arsenic anions but detected at m/z 121 and used as an internal standard for their qualitative analysis. Arsenite was prone to oxidation....... The argon chloride interference at m/z 75 was eliminated by chromatographic separation of the chloride present in the sample from the arsenic analytes. The ClO+ ion detected at m/z 51 and 53 was used to monitor the retention time of chloride in the anion-exchange system. The chloride eluted about 100 s...

  14. Profiling of kidney vascular endothelial cell plasma membrane proteins by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Liu, Zan; Xu, Bo; Nameta, Masaaki; Zhang, Ying; Magdeldin, Sameh; Yoshida, Yutaka; Yamamoto, Keiko; Fujinaka, Hidehiko; Yaoita, Eishin; Tasaki, Masayuki; Nakagawa, Yuki; Saito, Kazuhide; Takahashi, Kota; Yamamoto, Tadashi

    2013-06-01

    Vascular endothelial cells (VECs) play crucial roles in physiological and pathologic conditions in tissues and organs. Most of these roles are related to VEC plasma membrane proteins. In the kidney, VECs are closely associated with structures and functions; however, plasma membrane proteins in kidney VECs remain to be fully elucidated. Rat kidneys were perfused with cationic colloidal silica nanoparticles (CCSN) to label the VEC plasma membrane. The CCSN-labeled plasma membrane fraction was collected by gradient ultracentrifugation. The VEC plasma membrane or whole-kidney lysate proteins were separated by sodium dodecyl sulfate polyacrylamide gel electrophoresis and digested with trypsin in gels for liquid chromatography-tandem mass spectrometry. Enrichment analysis was then performed. The VEC plasma membrane proteins were purified by the CCSN method with high yield (approximately 20 μg from 1 g of rat kidney). By Mascot search, 582 proteins were identified in the VEC plasma membrane fraction, and 1,205 proteins were identified in the kidney lysate. In addition to 16 VEC marker proteins such as integrin beta-1 and intercellular adhesion molecule-2 (ICAM-2), 8 novel proteins such as Deltex 3-like protein and phosphatidylinositol binding clathrin assembly protein (PICALM) were identified. As expected, many key functions of plasma membranes in general and of endothelial cells in particular (i.e., leukocyte adhesion) were significantly overrepresented in the proteome of CCSN-labeled kidney VEC fraction. The CCSN method is a reliable technique for isolation of VEC plasma membrane from the kidney, and proteomic analysis followed by bioinformatics revealed the characteristics of in vivo VECs in the kidney.

  15. Determination of aflatoxins in medicinal plants by high-performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Siddique, Nadeem A; Mujeeb, Mohd; Ahmad, Sayeed; Panda, Bibhu P; Makhmoor, Mohd

    2013-01-01

    The intention of the proposed work is to study the presence of the aflatoxins B1, B2, G1 and G2 in medicinal plants, namely Mucuna pruriens, Delphinium denudatum and Portulaca oleraceae. The aflatoxins were extracted, purified by immunoaffinity column chromatography and analysed by high-performance liquid chromatography-tandem quadrupole mass spectrometry with electrospray ionisation (HPLC-MS/MS). Fungal count was carried out in PDA media. A good linear relationship was found for AFB1, AFB2, AFG1 and AFG2 at 1-10 ppb (r>0.9995). The analyte accuracy under three different spiking levels was 86.7-108.1 %, with low per cent relative standard deviations in each case. The aflatoxins can be separated within 5 to7 min using an Agilent XDB C18-column. We found that AFB1 and AFB2 were in trace amounts below the detection limit in M. pruriens whilst they were not detected in D. denudatum. P. oleraceae was found to be contaminated with AFB1 and AFB2. AFG1 and AFG2 were not detected in M. pruriens, P. oleraceae and were below the detection limit in D. denudatum. This was consistent with very low numbers of fungal colonies observed after 6 hr of incubation. The analytical method developed is simple, precise, accurate, economical and can be effectively used to determine the aflatoxins in medicinal plants and therefore to control the quality of products. The aflatoxin levels in the plant extracts examined were related to the minimal fungal load in the medicinal plants examined.

  16. Simultaneous quantification of Pacific ciguatoxins in fish blood using liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Mak, Yim Ling; Wu, Jia Jun; Chan, Wing Hei; Murphy, Margaret B; Lam, James C W; Chan, Leo L; Lam, Paul K S

    2013-04-01

    Ciguatera fish poisoning (CFP) is a food intoxication caused by exposure to ciguatoxins (CTXs) in coral reef fish. Rapid analytical methods have been developed recently to quantify Pacific-CTX-1 (P-CTX-1) in fish muscle, but it is destructive and can cause harm to valuable live coral reef fish. Also fish muscle extract was complex making CTX quantification challenging. Not only P-CTX-1, but also P-CTX-2 and P-CTX-3 could be present in fish, contributing to ciguatoxicity. Therefore, an analytical method for simultaneous quantification of P-CTX-1, P-CTX-2, and P-CTX-3 in whole blood of marketed coral reef fish using sonication, solid-phase extraction (SPE), and liquid chromatography tandem mass spectrometry (LC-MS/MS) was developed. The optimized method gave acceptable recoveries of P-CTXs (74-103 %) in fish blood. Matrix effects (6-26 %) in blood extracts were found to be significantly reduced compared with those in muscle extracts (suppressed by 34-75 % as reported in other studies), thereby minimizing potential for false negative results. The target P-CTXs were detectable in whole blood from four coral reef fish species collected in a CFP-endemic region. Similar trends in total P-CTX levels and patterns of P-CTX composition profiles in blood and muscle of these fish were observed, suggesting a relationship between blood and muscle levels of P-CTXs. This optimized method provides an essential tool for studies of P-CTX pharmacokinetics and pharmacodynamics in fish, which are needed for establishing the use of fish blood as a reliable sample for the assessment and control of CFP.

  17. Simultaneous quantification of multiple urinary naphthalene metabolites by liquid chromatography tandem mass spectrometry.

    Directory of Open Access Journals (Sweden)

    Daniel C Ayala

    Full Text Available Naphthalene is an environmental toxicant to which humans are exposed. Naphthalene causes dose-dependent cytotoxicity to murine airway epithelial cells but a link between exposure and human pulmonary disease has not been established. Naphthalene toxicity in rodents depends on P450 metabolism. Subsequent biotransformation results in urinary elimination of several conjugated metabolites. Glucuronide and sulfate conjugates of naphthols have been used as markers of naphthalene exposure but, as the current studies demonstrate, these assays provide a limited view of the range of metabolites generated from the parent hydrocarbon. Here, we present a liquid chromatography tandem mass spectrometry method for measurement of the glucuronide and sulfate conjugates of 1-naphthol as well as the mercapturic acids and N-acetyl glutathione conjugates from naphthalene epoxide. Standard curves were linear over 2 log orders. On column detection limits varied from 0.91 to 3.4 ng; limits of quantitation from 1.8 to 6.4 ng. The accuracy of measurement of spiked urine standards was -13.1 to + 5.2% of target and intra-day and inter-day variability averaged 7.2 (± 4.5 and 6.8 (± 5.0 %, respectively. Application of the method to urine collected from mice exposed to naphthalene at 15 ppm (4 hrs showed that glutathione-derived metabolites accounted for 60-70% of the total measured metabolites and sulfate and glucuronide conjugates were eliminated in equal amounts. The method is robust and directly measures several major naphthalene metabolites including those derived from glutathione conjugation of naphthalene epoxide. The assays do not require enzymatic deconjugation, extraction or derivatization thus simplifying sample work up.

  18. [Measurement of sialic acid from lipoproteins and human plasma by liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Guo, Shoudong; Sang, Hui; Yang, Nana; Kan, Yujie; Li, Fuyu; Li, Yu; Li, Fangyuan; Qin, Shucun

    2014-11-01

    A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was established to quantify sialic acid (N-acetylneuraminic acid, NANA) from lipoproteins and human plasma. The method was used to investigate the different contents of NANA from lipoproteins between diabetic with an average age of 51.6 years and healthy participants with an average age of 50.7 years. The NANA from lipoprotein samples was hydrolyzed by acetic acid (pH = 2) at 80 °C for 2 h and analyzed by the optimized LC-MS/MS method after high speed centrifugation and filtration. The limits of detection and quantification of NANA were 7.4 and 24.5 pg, respectively. The linear range was 2.5-80 ng/mL for NANA and the correlation coefficient (R2) was more than 0.998. The levels of NANA in the plasma of type II diabetics and healthy participants were (548.3 ± 88.9) and (415.3 ± 55.5) mg/L, respectively; and the levels of NANA from very low density lipoproteins (VLDL), low density lipoproteins (LDL), and high density lipoproteins (HDL) of the type II diabetics and the healthy participants were (4.91 ± 0.19), (6.95 ± 0.28), (3.61 ± 0.22) μg/mg and (2.90 ± 0.27), (7.03 ± 0.04), (2.40 ± 0.09) μg/mg, respectively. The sialic acid levels of VLDL and HDL from the type II diabetics were markedly higher than those of the corresponding healthy participants with the similar ages (P lipoproteins, and is reproducible and time saving.

  19. Applying liquid chromatography-tandem mass spectrometry to assess endodontic sealer microleakage

    Directory of Open Access Journals (Sweden)

    André Luiz da Costa MICHELOTTO

    2015-01-01

    Full Text Available The objective of this study was to describe a new method for the quantitative analysis of a microleakage of endodontic filling materials. Forty extracted single-rooted teeth were randomly divided into three experimental groups. After root canal shaping, the experimental groups were filled using the lateral condensation technique with the Epiphany system (G1, with gutta-percha + Sealapex (G2, and with gutta-percha + AH Plus (G3. Each root was mounted on a modified leakage testing device, and caffeine solution was used as a tracer (2000 ng mL-1, pH 6.0, applied in the coronal direction towards the tooth apex, creating a hydrostatic pressure of 2.55 kPa. Presence of caffeine in the receiving solution was measured after 10, 30, and 60 days, using high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS. None of the groups presented microleakage at 10 days. At 30 days, G2 and G3 showed similar infiltration patterns (means: 16.0 and 13.9 ng mL-1, respectively, whereas G1 showed significantly higher values (mean: 105.2 ng mL-1. At 60 days, leakage values were 182.6 ng mL-1for G1, 139.0 ng mL-1 for G2, and 53.5 ng mL-1 for G3. AH Plus showed the best sealing ability and HPLC-MS/MS showed high sensitivity and specificity for tracer quantification.

  20. High performance liquid chromatographic-mass spectrometric assay for the quantitation of BMS-204352 in dog K(3)EDTA plasma.

    Science.gov (United States)

    Yao, Ming; Mantha, Subbarao; Shah, Vinod R; Vachharajani, Nimish N; Arnold, Mark E; Pursley, Janice M; Srinivas, Nuggehally R

    2002-05-01

    A high performance liquid chromatographic-mass spectrometric (LC/MS) assay was developed and validated for the determination of BMS-204352 in dog K(3)EDTA plasma. A 0.5 mL aliquot of control plasma was spiked with BMS-204352 and internal standard (IS) and buffered with 1 mL of 5 mM ammonium acetate. The mixture was then extracted with 3 mL of toluene. After separation and evaporation of the organic phase to dryness using nitrogen at 40 degrees C, the residue was reconstituted in the mobile phase and 25 microL of the sample were injected onto a Hypersil C(18) column (2 x 50 mm; 3 microm) at a flow rate of 0.5 mL/min. The mobile phase was consisted of two solvent mixtures (A and B). Solvent A was composed of 5 mM ammonium acetate and 0.1% triethylamine in 75:25 v/v water:methanol, pH adjusted to 5.5 with glacial acetic acid, and solvent B was 5 mM ammonium acetate in methanol. A linear gradient system was used to elute the analytes. The mass spectrometer was programmed to admit the de-protonated molecules at m/z 352.7 (IS) and m/z 357.9 (BMS-204352). Standard curves of BMS-204352 were linear (r(2) > or = 0.998) over the concentration range of 0.5-1000 ng/mL. The mean predicted quality control (QC) concentrations deviated less than 5.1% from the corresponding nominal values (ie 4, 80, 400 and 2000 ng/mL); the within- and between-assay precision of the assay were within 5.5% relative standard deviation. Stability of BMS-204352 was confirmed after at least three freeze/thaw cycles and BMS-204532 was stable in dog plasma when stored frozen at or below -20 degrees C for at least 16 weeks in spiked QC samples and for at least 4 1/2 weeks for in vivo study samples. BMS-204352 and IS were stable in the injection solvent at room temperature for at least 24 h. The assay was applied to delineate the pharmacokinetic disposition of BMS-204352 in dogs following a single intravenous dose administration. In conclusion, the assay is accurate, precise, specific, sensitive and

  1. Improved stochastic resonance algorithm for enhancement of signal-to-noise ratio of high-performance liquid chromatographic signal

    International Nuclear Information System (INIS)

    Xie Shaofei; Xiang Bingren; Deng Haishan; Xiang Suyun; Lu Jun

    2007-01-01

    Based on the theory of stochastic resonance, an improved stochastic resonance algorithm with a new criterion for optimizing system parameters to enhance signal-to-noise ratio (SNR) of HPLC/UV chromatographic signal for trace analysis was presented in this study. Compared with the conventional criterion in stochastic resonance, the proposed one can ensure satisfactory SNR as well as good peak shape of chromatographic peak in output signal. Application of the criterion to experimental weak signals of HPLC/UV was investigated and the results showed an excellent quantitative relationship between different concentrations and responses

  2. Development of Chromatographic Fingerprints of Eurycoma longifolia (Tongkat Ali Roots Using Online Solid Phase Extraction-Liquid Chromatography (SPE-LC

    Directory of Open Access Journals (Sweden)

    Nor Nasriah Zaini

    2016-04-01

    Full Text Available E. longifolia is attracting interest due to its pharmacological properties and pro-vitality effects. In this study, an online SPE-LC approach using polystyrene divinyl benzene (PSDVB and C18 columns was developed in obtaining chromatographic fingerprints of E. longifolia. E. longifolia root samples were extracted using pressurized liquid extraction (PLE technique prior to online SPE-LC. The effects of mobile phase compositions and column switching time on the chromatographic fingerprint were optimized. Validation of the developed method was studied based on eurycomanone. Linearity was in the range of 5 to 50 µg∙mL−1 (r2 = 0.997 with 3.2% relative standard deviation of peak area. The developed method was used to analyze 14 E. longifolia root samples and 10 products (capsules. Selected chemometric techniques: cluster analysis (CA, discriminant analysis (DA, and principal component analysis (PCA were applied to the fingerprint datasets of 37 selected peaks to evaluate the ability of the chromatographic fingerprint in classifying quality of E. longifolia. Three groups were obtained using CA. DA yielded 100% correlation coefficient with 19 discriminant compounds. Using PCA, E. longifolia root samples were clearly discriminated from the products. This study showed that the developed online SPE-LC method was able to provide comprehensive evaluation of E. longifolia samples for quality control purposes.

  3. A multiresidue method by high performance liquid chromatography-based fractionation and gas chromatographic determination of trace levels of pesticides in air and water.

    Science.gov (United States)

    Seiber, J N; Glotfelty, D E; Lucas, A D; McChesney, M M; Sagebiel, J C; Wehner, T A

    1990-01-01

    A multiresidue analytical method is described for pesticides, transformation products, and related toxicants based upon high performance liquid chromatographic (HPLC) fractionation of extracted residue on a Partisil silica gel normal phase column followed by selective-detector gas chromatographic (GC) determination of components in each fraction. The HPLC mobile phase gradient (hexane to methyl t-butyl ether) gave good chromatographic efficiency, resolution, reproducibility and recovery for 61 test compounds, and allowed for collection in four fractions spanning polarities from low polarity organochlorine compounds (fraction 1) to polar N-methylcarbamates and organophosphorus oxons (fraction 4). The multiresidue method was developed for use with air samples collected on XAD-4 and related trapping agents, and water samples extracted with methylene chloride. Detection limits estimated from spiking experiments were generally 0.3-1 ng/m3 for high-volume air samples, and 0.01-0.1 microgram/L for one-liter water samples. Applications were made to determination of pesticides in fogwater and air samples.

  4. Food safety evaluation: Detection and confirmation of chloramphenicol in milk by high performance liquid chromatography-tandem mass spectrometry

    International Nuclear Information System (INIS)

    Nicolich, Rebecca S.; Werneck-Barroso, Eduardo; Marques, Marlice A. Sipoli

    2006-01-01

    A simple and rapid procedure for extraction of chloramphenicol (CAP) in milk and analysis by high-performance liquid chromatography coupled with quadrupole mass spectrometry in tandem was developed. The method consisted of one step of liquid-liquid extraction using ethyl acetate and acidified water (10 mmol L -1 formic acid) and HPLC-MS/MS detection. CAP-D5 was used as internal standard. The method was validated according to Commission Decision 2002/657/EC. The calibration curves were linear, with typical r 2 values higher than 0.98. Absolute recovery of CAP from milk proved to be more than 95%, however CAP-D5 absolute recovery was 75%. The method was accurate and reproducible, being successfully applied to the monitoring of CAP in milk samples obtained from the Brazilian market. Decision limit (CCα) was 0.05 ng mL -1 and detection capability (CCβ) was 0.09 ng mL -1

  5. Development of a liquid chromatography-electrospray chemical ionization tandem mass spectrometry analytical method for analysis of eleven hydroxylated polybrominated diphenyl ethers.

    Science.gov (United States)

    Feo, Maria Luisa; Barón, Enrique; Aga, Diana S; Eljarrat, Ethel; Barceló, Damià

    2013-08-02

    Recently, hydroxylated polybrominated diphenyl ethers (OH-PBDEs) have emerged as environmentally relevant pollutants due to recent reports of their natural production and metabolism. Recent mechanistic studies in human and rats have shown that some OH-PBDEs are more potent than parent compounds (PBDEs) and may contribute substantially to neurodevelopmental disorders by direct neurotoxicity, or indirectly through altered thyroid disruption. However, analytical methodologies for determination of OH-PBDEs are currently limited. In this study a robust liquid chromatography-electrospray tandem triple quadrupole-linear ion trap mass spectrometer (LC-ESI-QqLIT-MS-MS) in negative mode method was developed for the determination of eleven OH-tri- to OH-hexa-PBDEs. Two different columns were tested and compared for chromatographic separation: a C18 BetaBasic and a Purospher STAR RP 18, working at pH 8 and 10, respectively. Mobile phase (acetonitrile:water) was optimized by changing the pH of the aqueous phase and the concentration of the organic modifier (methanol). The MS-MS parameters (declustering potential (DP), collision energy (CE) and cell exit potential (CXP)) were optimized. Selected reaction monitoring (SRM) was used in order to increase sensitivity. Two SRM transitions ([M-H](-)>[Br](-)) were selected for each OH-PBDE, one for quantification and the second one for confirmation. Under the optimized conditions, the instrumental limits of detection were between 0.17 and 0.72injectedpg. The method provided good linearity (r>0.99 for a concentration range of 0.30-100ng/mL), accuracy and precision (%Dev and %RSD≤20% for intra- and inter-assays). Copyright © 2013 Elsevier B.V. All rights reserved.

  6. Simultaneous Determination of Black Tea-Derived Catechins and Theaflavins in Tissues of Tea Consuming Animals Using Ultra-Performance Liquid-Chromatography Tandem Mass Spectrometry

    Science.gov (United States)

    Ganguly, Souradipta; G., Taposh Kumar; Mantha, Sudarshan

    2016-01-01

    The bioavailability, tissue distribution and metabolic fate of the major tea polyphenols, catechins and theaflavins as well as their gallated derivatives are yet to be precisely elucidated on a single identification platform for assessment of their relative bioefficacy in vivo. This is primarily due to the lack of suitable analytical tools for their simultaneous determination especially in an in vivo setting, which continues to constrain the evaluation of their relative health beneficiary potential and therefore prospective therapeutic application. Herein, we report a rapid and sensitive Ultra-Performance Liquid Chromatography Tandem Mass Spectrometry (UPLC-MS/MS) based method for the simultaneous determination of the major catechins and theaflavins in black tea infusions as well as in different vital tissues and body fluids of tea-consuming guinea pigs. This method allowed efficient separation of all polyphenols within seven minutes of chromatographic run and had a lower limit of quantification (LLOQ) of ~5 ng/ml. Using this method, almost all bioactive catechins and theaflavins could be simultaneously detected in the plasma of guinea pigs orally administered 5% black tea for 14 days. Our method could further detect the majority of these polyphenols in the lung and kidney as well as identify the major catechin metabolites in the urine of the tea-consuming animals. Overall, our study presents a novel tool for simultaneous detection and quantitation of both catechins and theaflavins in a single detection platform that could potentially enable precise elucidation of their relative bioavailability and bioefficacy as well as true health beneficiary potential in vivo. Such information would ultimately facilitate the accurate designing of therapeutic strategies utilizing high efficacy formulations of tea polyphenols for effective mitigation of oxidative damage and inflammation in humans as well as prevention of associated diseases. PMID:27695123

  7. Analysis of 17 neurotransmitters, metabolites and precursors in zebrafish through the life cycle using ultrahigh performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Santos-Fandila, A; Vázquez, E; Barranco, A; Zafra-Gómez, A; Navalón, A; Rueda, R; Ramírez, M

    2015-09-15

    An ultrahigh performance liquid chromatography-tandem mass spectrometry method for the identification and quantification of neurotransmitters, metabolites and precursors at different stages in zebrafish life was developed. Betaine, glutamine, glutamic acid, γ-aminobutyric acid, phosphocholine, glycerophosphocholine, cytidine 5'-diphosphocholine, choline, acetylcholine, dopamine, norepinephrine, serotonin, tyrosine, epinephrine, tryptophan, 5-hydroxyindolacetic acid and agmatine were selected as analytes. The method consisted of a simple deproteinization of samples using methanol and formic acid, subsequent injection onto the chromatographic equipment and quantification with a triple quadrupole mass spectrometer detector using an electrospray ionization interface in positive mode. Limits of detection ranged from 0.02 to 11ngmL(-1) and limits of quantification from 0.1 to 38ngmL(-1), depending on the analyte. The method was validated according to US Food and Drugs Administration (FDA) guideline for bioanalytical assays. Precision, expressed as relative standard deviation (%RSD), was lower than 15% in all cases, and the determination coefficient (R(2)) was equal or higher than 99.0% with a residual deviation for each calibration point lower than ±25%. Mean recoveries were between 85% and 115%. The method was applied to determine of these compounds in zebrafish from early stages of development to adulthood and showed the time-course of neurotransmitters and others neurocompounds through the life cycle. The possibility of measuring up to 17 compounds related with the main neurotransmitter systems in a simple analytical method will complement and reinforce the use of zebrafish in multiple applications in the field of neurosciences. The proposed method will facilitate future studies related with brain development. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Determination of natamycin in rabbit cornea by high-performance liquid chromatography-tandem mass spectrometry with protective soaking extraction technology.

    Science.gov (United States)

    Tianyang, Zhou; Ling, Zhu; Huiyun, Xia; Jijun, He; Junjie, Zhang

    2014-10-15

    A new selective and sensitive high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was developed for the quantification of natamycin (NAT) in rabbit corneas with amphotericin B as the internal standard (IS). The cornea samples were processed by a simple and protective methanol soaking extraction technology. The NAT could be extracted completely from rabbit cornea after 24h of soaking with methanol under a mild condition. Chromatographic separation was performed on a C18 column (2.1mm×50mm, 3.5μm) using mobile phase with ammonium acetate buffer (pH 4.5; 4.0mM):acetonitrile (40:60, v/v) at a flow rate of 0.25ml/min. Quantification was performed using the transitions 666.2→503.2 m/z for NAT and 924.5→906.6 m/z for IS by positive ion electrospray ionization in multiple reaction monitoring mode. The assay was validated over a concentration range of 8.64ng/ml to 843ng/ml with lower limit of detection of 4.32ng/ml. The method was validated with respect to linearity, accuracy, precision, recovery, stability and extracting efficiency. The extraction recovery of NAT from cornea samples was approximately 100% with the new methanol soaking extraction procedure. The method has been successfully applied to the ocular pharmacokinetic studies of NAT eye drops in the cornea of Japanese white rabbit. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Therapeutic drug monitoring of carbamazepine and its metabolite in children from dried blood spots using liquid chromatography and tandem mass spectrometry.

    Science.gov (United States)

    Shokry, Engy; Villanelli, Fabio; Malvagia, Sabrina; Rosati, Anna; Forni, Giulia; Funghini, Silvia; Ombrone, Daniela; Della Bona, Maria; Guerrini, Renzo; la Marca, Giancarlo

    2015-05-10

    Carbamazepine (CBZ) is a first-line drug for the treatment of different forms of epilepsy and the first choice drug for trigeminal neuralgia. CBZ is metabolized in the liver by oxidation into carbamazepine-10,11-epoxide (CBZE), its major metabolite which is equipotent and known to contribute to the pharmacological activity of CBZ. The aim of the present study was to develop and validate a reliable, selective and sensitive liquid chromatography-tandem mass spectrometry method for the simultaneous quantification of CBZ and its active metabolite in dried blood spots (DBS). The extraction process was carried out from DBS using methanol-water-formic acid (80:20:0.1, v/v/v). Chromatographic elution was achieved by using a linear gradient with a mobile phase consisting of acetonitrile-water-0.1% formic acid at a flow rate of 0.50mL/min. The method was linear over the range 1-40mg/L and 0.25-20mg/L for CBZ and CBZE, respectively. The limit of quantification was 0.75mg/L and 0.25mg/L for CBZ and CBZE. Intra-day and inter-day assay precisions were found to be lower than 5.13%, 6.46% and 11.76%, 4.72% with mean percentage accuracies of 102.1%, 97.5% and 99.2%, 97.8% for CBZ and CBZE. We successfully applied the method for determining DBS finger-prick samples in paediatric patients and confirmed the results with concentrations measured in matched plasma samples. This novel approach allows quantification of CBZ and its metabolite from only one 3.2mm DBS disc by LC-MS/MS thus combining advantages of DBS technique and LC-MS/MS in clinical practice. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Pharmacokinetic determination of ephedrine in Herba Ephedrae and Wu Tou Tang decoctions in rats using ultra performance liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Zheng, Zhijie; Yan, Tongmeng; Chen, Weiying; Ye, Ling; Tang, Lan; Liu, Zhongqiu

    2012-08-01

    A rapid and sensitive ultra performance liquid chromatography tandem mass spectrometry method was developed and validated for the determination and quantification of ephedrine in rat plasma samples. An Acquity UPLC BEH C18 column (1.7 μm, 2.1 mm × 50 mm) was used for chromatographic separation. Electrospray ionization in the positive mode was used, and the precursor-fragment ion pairs of m/z 166/148 and m/z 289/97 were adopted to characterize ephedrine and testosterone (internal standard), respectively. The method was validated using 10, 100 and 500 ng/mL of ephedrine. It demonstrated adequate levels of precision and accuracy, matrix effect, extraction recovery and stability. Linearity over the concentration range of 0.5-2000 ng/mL was acceptable with a correlation coefficient (r²) better than 0.990. To determine the pharmacokinetic behaviour of this sympathomimetic compound in the Sprague-Dawley rats, ephedrine hydrochloride, Herba Ephedrae single-herb and Wu Tou Tang decoctions were administered orally, and ephedrine hydrochloride was also administered by intravenous injection, and blood samples were collected over 24 h. Ephedrine was measured in plasma and pharmacokinetic parameters were determined by using the standard non-compartmental method and calculated by using Practical Pharmacokinetic Program-Version 87/97. The AUC(0-t) and T(max) values were significantly different (p Tang decoction compared to the other oral treatments, suggesting that some components in the decoction may reduce the bioavailability of ephedrine.

  11. Investigation of absolute and relative response for three different liquid chromatography/tandem mass spectrometry systems; the impact of ionization and detection saturation.

    Science.gov (United States)

    Nilsson, Lars B; Skansen, Patrik

    2012-06-30

    The investigations in this article were triggered by two observations in the laboratory; for some liquid chromatography/tandem mass spectrometry (LC/MS/MS) systems it was possible to obtain linear calibration curves for extreme concentration ranges and for some systems seemingly linear calibration curves gave good accuracy at low concentrations only when using a quadratic regression function. The absolute and relative responses were tested for three different LC/MS/MS systems by injecting solutions of a model compound and a stable isotope labeled internal standard. The analyte concentration range for the solutions was 0.00391 to 500 μM (128,000×), giving overload of the chromatographic column at the highest concentrations. The stable isotope labeled internal standard concentration was 0.667 μM in all samples. The absolute response per concentration unit decreased rapidly as higher concentrations were injected. The relative response, the ratio for the analyte peak area to the internal standard peak area, per concentration unit was calculated. For system 1, the ionization process was found to limit the response and the relative response per concentration unit was constant. For systems 2 and 3, the ion detection process was the limiting factor resulting in decreasing relative response at increasing concentrations. For systems behaving like system 1, simple linear regression can be used for any concentration range while, for systems behaving like systems 2 and 3, non-linear regression is recommended for all concentration ranges. Another consequence is that the ionization capacity limited systems will be insensitive to matrix ion suppression when an ideal internal standard is used while the detection capacity limited systems are at risk of giving erroneous results at high concentrations if the matrix ion suppression varies for different samples in a run. Copyright © 2012 John Wiley & Sons, Ltd.

  12. A liquid chromatography with tandem mass spectrometry method for simultaneous determination of UTL-5g and its metabolites in human plasma.

    Science.gov (United States)

    Shaw, Jiajiu; Wiegand, Richard; Wu, Jianmei; Bao, Xun; Valeriote, Frederick; Li, Jing

    2015-06-01

    UTL-5g is a novel small-molecule TNF-α inhibitor under investigation as both a chemoprotective and radioprotective agent. Animal studies showed that pretreatment of UTL-5g protected kidney, liver, and platelets from cisplatin-induced toxicity. In addition, UTL-5g reduced liver and lung injuries induced by radiation in vivo. Although a number of preclinical studies have been conducted, a validated bioanalytical method for UTL-5g in human plasma has not been published. In this work, a sensitive and reproducible reverse-phase liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) assay was developed and validated for the determination of UTL-5g and its metabolites, 5-methylisoxazole-3-carboxylic acid (ISOX) and 2,4-dichloroaniline (DCA), in human plasma. The method involves a simple methanol precipitation step followed by injection of the supernatant onto a Waters 2695 HPLC system coupled with a Waters Quattro Micro™ triple quadrupole mass spectrometer. Chromatographic separation was accomplished using a Waters Nova-Pak C18 column maintained at 30°C, running at gradient mode with mobile phase consisting of 0.1% formic acid in water and 0.1% formic acid in methanol at a flow rate of 0.2mL/min. The analytes were monitored under positive electrospray ionization (ESI). Quantitation of these compounds in plasma was linear from 0.05 to 10μM. The lower limit of quantitation (LLOQ) was 0.05, 0.1, and 0.2μM for UTL-5g, ISOX and DCA, respectively. The accuracy and intra-and inter-day precisions were within the generally accepted criteria for bioanalytical method (5g and its metabolites, ISOX and DCA. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Development of a new ultra-high performance liquid chromatography - tandem mass spectrometry method for determination of ambroxol hydrochloride in serum with pharmacokinetic application

    Directory of Open Access Journals (Sweden)

    Vujović Maja M.

    2016-01-01

    Full Text Available Ambroxol hydrochloride is an expectorant agent, successfully applied in mucolytic therapy for acute and chronic bronchopulmonary diseases. The drug regulates not only mucus secretion but also showed antioxidant, anti-inflammatory and local anesthetic properties. To supplement the pharmacokinetic and toxicological studies of ambroxol, a rapid ultra-high performance liquid chromatography-tandem mass spectrometry method for the quantitation of ambroxol in rabbit serum was developed. A validation of the method was performed as per the ICH guidelines for the validation of bioanalytical methods. The chromatographic separation was achieved in a submicron Kinetex RP - C18 - column (2.1 mm x 50 mm, 1.3μm using the no buffer mobile phase. The ESI mass spectrometry in the MRM mode was used with a typical transitions m/z 378.9→263.8 for ambroxol and m/z 455.2→165.0 for IS. Linearity was determined with an average coefficient of determination >0.999 over the dynamic range from 0.5 - 200 ng/mL with LOD and LOQ of 0.25 ng/mL and 0.5 ng/mL, respectively. The results of the intra- and inter-day precision and accuracy determined in different days were all found to be within the acceptable limits ±15%. The present method was successfully applied to pharmacokinetic study in the rabbits after a single oral dose administration. [Projekat Ministarstva nauke Republike Srbije, br. 175045

  14. Simultaneous determination of clevidipine and its primary metabolite in dog plasma by liquid chromatography-tandem mass spectrometry: Application to pharmacokinetic study.

    Science.gov (United States)

    Zhou, Ying; Li, Huqun; He, Xiaomeng; Jia, Mengmeng; Ni, Yang; Xu, Mingzhen; Chen, Hui; Li, Weiyong

    2014-11-01

    A simple and rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the simultaneous determination of clevidipine and its primary metabolite H152/81 in dog plasma after protein precipitation with acetonitrile using felodipine as the internal standard (IS). Chromatographic separation was performed on a XB C18 column (2.1mm×50mm, 3.5μm) under isocratic conditions with the mobile phase consisting of acetonitrile and 20mM ammonium acetate buffer (pH 7.0) (40:60, v/v) at the flow rate of 0.3ml/min. The run time was 5.5min. Mass spectrometric analysis was performed on a triple quadrupole mass spectrometer operated in the multiple reaction monitoring (MRM) mode with the transitions of m/z 473.0→338.2 for clevidipine, m/z 356.1→324.0 for H152/81 and m/z 383.9→338.2 for the IS. The method was fully validated in terms of selectivity, linearity, lower limit of quantification (LLOQ), accuracy, precision, stability, matrix effect and recovery over a concentration range of 0.15-200ng/ml for clevidipine and 10-2000ng/ml for H152/81, respectively. The analytical method was applied to support a pharmacokinetic study of simultaneous determination of clevidipine and H152/81 in ten healthy beagle dogs. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Identification and quantification of five macrolide antibiotics in several tissues, eggs and milk by liquid chromatography-electrospray tandem mass spectrometry.

    Science.gov (United States)

    Dubois, M; Fluchard, D; Sior, E; Delahaut, P

    2001-04-05

    We present an electrospray high-performance liquid chromatographic tandem mass spectrometric (HPLC-MS-MS) method capable of determining in several tissues (muscle, kidney, liver), eggs and milk the following five macrolides: tylosin, tilmicosin, spiramycin, josamycin, erythromycin. Roxithromycin was used as an internal standard. The method uses extraction in a Tris buffer at pH 10.5, followed by protein precipitation with sodium tungstate and clean-up on an Oasis solid-phase extraction column. The HPLC separation was performed on a Purospher C18 column (125 x 3 mm I.D.) protected by a guard column, with a gradient of aqueous 0.1 M ammonium acetate-acetonitrile as the mobile phase at a flow-rate of 0.7 ml min(-1). Protonated molecules served as precursor ions for electrospray ionisation in the positive ion mode and four product ions were chosen for each analyte for multiple reaction monitoring (MRM). A validation study was conducted to confirm the five macrolides by MRM HPLC-MS-MS analysis of a negative control and fortified samples. All of the samples analysed were confirmed with four ions. The ion ratio reproducibility limit ranged from 2.4 to 15%. All compounds could be detected and quantified at half-maximum residue limits (MRLs). The method is specific, quantitative and reproducible enough to conform to European Union recommendations within the concentration range 0.5 MRL-2 MRL (accuracy: 80 to 110%, relative standard deviation: 2 to 13%). This whole method allows extraction and analysis of up to 50 samples per day.

  16. Development and validation of an assay for the simultaneous determination of zidovudine, abacavir, emtricitabine, lamivudine, tenofovir and ribavirin in human plasma using liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Kromdijk, W; Pereira, S A; Rosing, H; Mulder, J W; Beijnen, J H; Huitema, A D R

    2013-03-01

    This paper describes the development and validation of an assay for the simultaneous quantification of the antiviral and antiretroviral drugs zidovudine, abacavir, emtricitabine, lamivudine, tenofovir and ribavirin in human plasma using liquid chromatography coupled to tandem mass spectrometry. Sample pretreatment consisted of protein precipitation with 0.1% (v/v) formic acid in methanol, evaporation and reconstitution. Chromatographic separation was performed on a Synergy Polar reversed phase C18 column (150 mm × 2.0 mm ID, particle size 4 μm) using a stepwise gradient with 0.1% (v/v) formic acid in water and 0.1% (v/v) formic acid in methanol at a flow rate of 300 μL/min. A triple quadrupole mass spectrometer operating in the positive ionization mode was used for drug detection and quantification. Isotopically labeled zidovudine, lamivudine, tenofovir and ribavirin were used as internal standards. The method was validated over a clinical range of 20-2500 ng/mL for zidovudine, lamivudine and tenofovir, 4-500 ng/mL for abacavir and emtricitabine and 160-20,000 ng/mL for ribavirin. The inter and intra-assay accuracies and precisions were between -8.47% and 14.2% for zidovudine, emtricitabine and ribavirin. For abacavir, lamivudine and tenofovir, the inter and intra-assay accuracies and precisions at the lower limit of quantification were between -11.0% and 18.3%, whereas at all other levels these accuracies and precisions were between -11.7% and 12.0%. The described method is suitable for the determination of zidovudine, abacavir, emtricitabine, lamivudine, tenofovir and ribavirin in human plasma in clinical practice to monitor plasma concentrations in selected cases to optimize therapy. Copyright © 2013. Published by Elsevier B.V.

  17. Liquid chromatography-tandem mass spectrometry multiresidue method for the analysis of quaternary ammonium compounds in cheese and milk products: Development and validation using the total error approach.

    Science.gov (United States)

    Slimani, Kahina; Féret, Aurélie; Pirotais, Yvette; Maris, Pierre; Abjean, Jean-Pierre; Hurtaud-Pessel, Dominique

    2017-09-29

    Quaternary ammonium compounds (QACs) are both cationic surfactants and biocidal substances widely used as disinfectants in the food industry. A sensitive and reliable method for the analysis of benzalkonium chlorides (BACs) and dialkyldimethylammonium chlorides (DDACs) has been developed that enables the simultaneous quantitative determination of ten quaternary ammonium residues in dairy products below the provisional maximum residue level (MRL), set at 0.1mgkg -1 . To the best of our knowledge, this method could be the one applicable to milk and to three major processed milk products selected, namely processed or hard pressed cheeses, and whole milk powder. The method comprises solvent extraction using a mixture of acetonitrile and ethyl acetate, without any further clean-up. Analyses were performed by liquid chromatography coupled with electrospray tandem mass spectrometry detection (LC-ESI-MS/MS) operating in positive mode. A C18 analytical column was used for chromatographic separation, with a mobile phase composed of acetonitrile and water both containing 0.3% formic acid; and methanol in the gradient mode. Five deuterated internal standards were added to obtain the most accurate quantification. Extraction recoveries were satisfactory and no matrix effects were observed. The method was validated using the total error approach in accordance with the NF V03-110 standard in order to characterize the trueness, repeatability, intermediate precision and analytical limits within the range of 5-150μgkg -1 for all matrices. These performance criteria, calculated by e.noval ® 3.0 software, were satisfactory and in full accordance with the proposed provisional MRL and with the recommendations in the European Union SANTE/11945/2015 regulatory guidelines. The limit of detection (LOD) was low (ammoniums in foodstuffs from dairy industries at residue levels, and could be used for biocide residues monitoring plans and to measure the exposition consumer to biocides products

  18. Determination of six microcystins and nodularin in surface and drinking waters by on-line solid phase extraction-ultra high pressure liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Beltrán, Eduardo; Ibáñez, María; Sancho, Juan Vicente; Hernández, Félix

    2012-11-30

    Microcystins and nodularin are cyclic peptides hepatotoxins produced by cyanobacterial genera (blue-green algae). Toxic cyanobacterial blooms are a worldwide problem, as reported in several countries, like China, Australia, or the United States. Therefore, it is necessary to develop sensitive and reliable analytical methodology to determine this type of toxins in water at parts per billion levels, or even lower. In this work, the potential of solid-phase extraction coupled on-line to ultra-high-pressure liquid chromatography/electrospray tandem mass spectrometry (SPE-UHPLC-MS/MS) has been investigated for the efficient quantification and confirmation of microcystins LR, RR, YR, LY, LW, LF and nodularin in surface and drinking water samples, at sub-ppb levels. The method developed involves the injection of only 1 mL of water sample into the on-line SPE-UHPLC-MS/MS system and allows the rapid determination of the compounds selected (8 min of chromatographic run), avoiding laborious sample treatment. The method was validated in surface and drinking water by means of recovery experiments at 0.25 and 1 μg L(-1). Average recoveries (n=5) ranged from 71 to 116%, with relative standard deviations (RSDs) lower than 15%. For microcystins LR, RR, YR and nodularin, a third level was also assayed (0.1 μg L(-1)) obtaining satisfactory data too. Limits of detection between 0.002 and 0.0405 μg L(-1) were estimated (0.0005 μg L(-1) for nodularin). The developed method was applied to the analysis of water samples collected in the province of Castellón (Spain). The acquisition of three MS/MS transitions for each compound allowed the unequivocal confirmation of positive samples, which was supported by the accomplishment of ion intensity ratios and retention time when compared with reference standards. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. Simultaneous determination of 41 multiclass organic pollutants in environmental waters by means of polyethersulfone microextraction followed by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Mijangos, Leire; Ziarrusta, Haizea; Olivares, Maitane; Zuloaga, Olatz; Möder, Monika; Etxebarria, Nestor; Prieto, Ailette

    2018-01-01

    A new procedure using polyethersulfone (PES) microextraction followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis was developed in this work for the simultaneous determination of 41 multiclass priority and emerging organic pollutants including herbicides, hormones, personal care products, and pharmaceuticals, among others, in seawater, wastewater treatment plant (WWTP) effluents, and estuary samples. The optimization of the analysis included two different chromatographic columns and different variables (polarity, fragmentor voltage, collision energy, and collision cell accelerator) of the mass spectrometer. In the case of PES extraction, ion strength of the water, pH, addition of EDTA, and the amount of the polymeric material were thoroughly investigated. The developed procedure was compared with a previously validated one based on a standard solid-phase extraction (SPE). In contrast to the SPE protocol, the PES method allowed a cost-efficient extraction of complex aqueous samples with lower matrix effect from 120 mL of water sample. Satisfactory and comparable apparent recovery values (80-119 and 70-131%) and method quantification limits (MQLs, 0.4-26 and 0.2-23 ng/L) were obtained for PES and SPE procedures, respectively, regardless of the matrix. Repeatability values lower than 27% were obtained. Finally, the developed methods were applied to the analysis of real samples from the Basque Country and irbesartan, valsartan, acesulfame, and sucralose were the analytes most often detected at the highest concentrations (51-1096 ng/L). Graphical abstract Forty-one multiclass pollutant determination in environmental waters by means of PES/SPE-LC-MS/MS.

  20. Analysis of fenretinide and its metabolites in human plasma by liquid chromatography-tandem mass spectrometry and its application to clinical pharmacokinetics.

    Science.gov (United States)

    Cho, Hwang Eui; Min, H Kang

    2017-01-05

    A simple and accurate high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the determination of N-(4-hydroxyphenyl)retinamide (fenretinide, 4-HPR) and its metabolites, 4-oxo-N-(4-hydroxyphenyl)retinamide (4-oxo-4-HPR) and N-(4-methoxyphenyl)retinamide (4-MPR), in human plasma. Plasma samples were prepared using protein precipitation with ethanol. Chromatographic separation of the three analytes and N-(4-ethoxyphenyl)retinamide (4-EPR), an internal standard, was achieved on a Zorbax SB-C18 column (3.5μm, 50×2.1mm) using gradient elution with the mobile phase of 0.1% formic acid in water and acetonitrile (pH* 2.4) at a flow rate of 0.5mL/min. Electrospray ionization (ESI) mass spectrometry was operated in the positive ion mode with multiple reaction monitoring (MRM). The calibration curves obtained were linear over the concentration range of 0.2-50ng/mL with a lower limit of quantification of 0.2ng/mL. The relative standard deviation of intra-day and inter-day precision was below 7.64%, and the accuracy ranged from 94.92 to 105.43%. The extraction recoveries were found to be higher than 90.39% and no matrix effect was observed. The analytes were stable for the durations of the stability studies. The validated method was successfully applied to the analyses of the pharmacokinetic study for patients treated with 4-HPR in a clinical trial. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Simultaneous Detection of Flavonoids, Phenolic Acids and Alkaloids in Abri Herba and Abri Mollis Herba using Liquid Chromatography Tandem Mass Spectrometry.

    Science.gov (United States)

    Yan, Wenying; Han, Qingjie; Guo, Panpan; Wang, Chunying; Zhang, Zijian

    2016-01-01

    Abri Herba has remarkable properties, such as cleanup heat detoxification, dampness and activating blood circulation to dissipate blood stasis; as a result, it has been applied to treat acute or chronic hepatitis and mastitis. Abri mollis Herba is often used as Abri Herba. Hierarchical cluster analysis (HCA) was applied to compare the similarities and differences of the chemical compositions in the two types of medicinal materials. To establish a high-performance liquid chromatography and tandem mass spectrometry (HPLC-MS/MS) method for the simultaneous analysis of 15 flavonoids, two phenolic acids and three alkaloids in Abri Herba and Abri mollis Herba. The chromatographic separation was performed on a C18 column with a mobile phase of methanol (A), acetonitrile (B) and 0.5‰ acetic acid in water (C) using gradient elution. The detection of the target compounds was performed in multiple-reaction monitoring (MRM) mode using a hybrid quadrupole linear ion trap mass spectrometer equipped with positive/negative ion-switching electrospray ionisation (ESI) source. The developed method is reliable, sensitive and specific. In addition, the method has been successfully applied to differentiate 15 batches of Abri Herba and 27 batches of Abri mollis Herba stems. Furthermore, a comparison of the contents among stems, roots and leaves from the same strain in seven batches of Abri mollis Herba and four batches of Abri Herba has also been performed. HPLC-MS/MS method is sensitive and selective and can be suitable for the reliable quality control of Abri mollis Herba and Abri Herba. Copyright © 2015 John Wiley & Sons, Ltd.

  2. Food Safety is an Important Public Health Issue: Chloramphenicol Residues Determination by Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS) in honey.

    Science.gov (United States)

    Krivohlavek, Adela; Žuntar, Irena; Ivešić, Martina; Andačić, Ivana Mandić; Šikić, Sandra

    2014-12-01

    Honey is used for nutritional, medicinal and industrial purposes and antibiotic residues may harm its quality and constitute a danger to human health. The broad spectrum antibiotic chloramphenicol (CAP) was used for curative purposes in veterinary medicine, but is now forbidden in European Union (EU) because of its many serious side effects (e.g. aplastic anaemia, grey syndrome, severe bone marrow depression and hypersensitivity). The aim of this study was to facilitate analyses of the quality and safety of Croatian honey distributed to whole European Union market; an assessment that has not previously been made. CAP in honey was qualifying and quantifying by validated liquid chromatography tandem mass spectrometry with negative electrospray ionisation method (LC-MS/MS). The target antibiotic was separated on chromatographic column Zorbax SB C18 (150 mm x 2.1 mm, 3.5 μm) with a gradient elution using acetonitrile - 0.1% formic acid mobile phase at a flow rate of 0.3 mL/min, with column temperature 35°C for CAP and 5D-CAP as internal standard. Homogenised honey samples were diluted with acetate buffer solution and extracted on Oasis Hydrophilic-Lipophilic-Balanced (HLB) sorbents. The method was used to analyse 280 domestic honey samples collected throughout Croatia between 2005.-2013. Recoveries of the method for real (acacia, chestnut, linden and flower) honey samples were 102% with RSD 8.4%. The value CCα and CCβ were 0.09 and 0.12 μg/kg, respectively. Results showed only three subsequent positive detections (1.1%) of CAP in honey. Analysed honey samples from Croatia showed good quality and safety what is the one of the main objective in consumer health policy in EU.

  3. Liquid chromatography-tandem mass spectrometry and passive sampling: powerful tools for the determination of emerging pollutants in water for human consumption.

    Science.gov (United States)

    Mirasole, Cristiana; Di Carro, Marina; Tanwar, Shivani; Magi, Emanuele

    2016-09-01

    Among the wide range of emerging pollutants, perfluorinated compounds and various pharmaceuticals, such as nonsteroidal anti-inflammatory drugs, are showing growing concern. These contaminants can be found in freshwater ecosystems because of their incomplete removal during wastewater treatments so, their water solubility and poor degradability result in their continuous discharge and pseudo-persistent contamination. Usually, expected levels of these analytes are particularly low; therefore, sensitive and selective analytical techniques are required for their determination. Moreover, sampling and preconcentration are fundamental steps to reach the low detection limits required. The polar organic chemical integrative sampler (POCIS) represents a modern sampling approach that allows the in-situ preconcentration of ultra-trace pollutants. In this work, a fast liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) method was developed for the determination of diclofenac, ketoprofen, mefenamic acid, naproxen, ibuprofen, perfluorooctanoic acid, perfluorooctanesulfonate and caffeine in water for human consumption. The chromatographic separation of analytes was achieved in less than 6 min. Quantitative analysis was performed in multiple reaction monitoring mode using ketoprofen-d3 as internal standard. Two different sites of Northern Italy were studied deploying POCIS for four weeks in both inlet and outlet of two drinking water treatment plants. The evaluation of time-weighted average concentration of contaminants was accomplished after the calibration of POCIS; to this aim, the sampling rate values for each compound were obtained by means of a simple calibration system developed in our laboratory. Ketoprofen, perfluorooctane sulfonate, perfluorooctanoate and caffeine were measured in both sites at the ng l(-1) level. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  4. Comprehensive determination of macrolide antibiotics, their synthesis intermediates and transformation products in wastewater effluents and ambient waters by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Senta, Ivan; Krizman-Matasic, Ivona; Terzic, Senka; Ahel, Marijan

    2017-08-04

    Macrolide antibiotics are a prominent group of emerging contaminants frequently found in wastewater effluents and wastewater-impacted aquatic environments. In this work, a novel analytical method for simultaneous determination of parent macrolide antibiotics (azithromycin, erythromycin, clarithromycin and roxithromycin), along with their synthesis intermediates, byproducts, metabolites and transformation products in wastewater and surface water was developed and validated. Samples were enriched using solid-phase extraction on Oasis HLB cartridges and analyzed by reversed-phase liquid chromatography coupled to electrospray ionization tandem mass spectrometry. The target macrolide compounds were separated on an ACE C18 PFP column and detected using multiple reaction monitoring in positive ionization polarity. The optimized method, which included an additional extract clean-up on strong anion-exchange cartridges (SAX), resulted in high recoveries and accuracies, low matrix effects and improved chromatographic separation of the target compounds, even in highly complex matrices, such as raw wastewater. The developed method was applied to the analysis of macrolide compounds in wastewater and river water samples from Croatia. In addition to parent antibiotics, several previously unreported macrolide transformation products and/or synthesis intermediates were detected in municipal wastewater, some of them reaching μg/L levels. Moreover, extremely high concentrations of macrolides up to mg/L level were found in pharmaceutical industry effluents, indicating possible importance of this source to the total loads into ambient waters. The results revealed a significant contribution of synthesis intermediates and transformation products to the overall mass balance of macrolides in the aquatic environment. Copyright © 2017. Published by Elsevier B.V.

  5. High-performance liquid chromatography-tandem mass spectrometry for simultaneous determination of raltegravir, dolutegravir and elvitegravir concentrations in human plasma and cerebrospinal fluid samples.

    Science.gov (United States)

    Tsuchiya, Kiyoto; Ohuchi, Mayu; Yamane, Naoe; Aikawa, Hiroaki; Gatanaga, Hiroyuki; Oka, Shinichi; Hamada, Akinobu

    2018-02-01

    A simple sample treatment procedure and sensitive liquid chromatography-tandem mass spectrometry method were developed for the simultaneous quantification of the concentrations of human immunodeficiency virus-1 integrase strand transfer inhibitors - raltegravir, dolutegravir and elvitegravir - in human plasma and cerebrospinal fluid (CSF). Plasma and CSF samples (20 μL each) were deproteinized with acetonitrile. Raltegravir-d 3 was used as the internal standard. Chromatographic separation was achieved on an XBridge C 18 column (50 × 2.1 mm i.d., particle size 3.5 μm) using acetonitrile-water (7:3, v/v) containing 0.1% formic acid as the mobile phase at a flow rate of 0.2 mL/min. The run time was 5 min. Calibration curves for all three drugs were linear in the range 5-1500 ng/mL for plasma and 1-200 ng/mL for CSF. The intra- and inter-day precision and accuracy of all three drugs in plasma were coefficient of variation (CV) <12.9% and 100.0 ± 12.2%, respectively, while those in CSF were CV <12.3% and 100.0 ± 7.9%, respectively. Successful validation under the same LC-MS/MS conditions for both plasma and CSF indicates this analytical method is useful for monitoring the levels of these integrase strand transfer inhibitors in the management of treatment of HIV-1 carriers. Copyright © 2017 John Wiley & Sons, Ltd.

  6. Determination of pesticide residues in olives by liquid extraction surface analysis followed by liquid chromatography/tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Gómez-Almenar, M. C.

    2015-06-01

    Full Text Available Nowadays, pesticides are essential in modern agriculture for crop protection, however, this use supposes a potential risk for human health and the environment. Traditional techniques of pesticide determination require the use of laborious and complex extraction methods to separate pesticides from the matrix, above all in fatty matrices like olives. For this reason, a new simple, rapid, cheap and selective method for the extraction and quantification of the most frequently used pesticides in olive growing has been developed. Pesticide determination was carried out by ultra-performance liquid chromatography (UPLC coupled with triple-quadrupole tandem mass spectrometry (MS/MS. Mean recoveries were found in a range between 73 and 114% with relative standard deviations lower than 20% in most pesticides evaluated and the limits of detection (LODs and quantification (LOQs were lower than 4 μg· kg-1 and 8 μg· kg-1, respectively. Finally, this method was applied to the analysis of 25 olive samples where Dimethoate and Terbuthylazine were detected in some cases, but their results were lower than 15 μg· kg-1.Hoy en día los pesticidas son esenciales en la agricultura moderna para la protección de los cultivos pero su uso supone un riesgo para la salud y el medio ambiente. Las técnicas tradicionales de determinación de pesticidas requieren el uso de métodos de extracción complejos a fin de separar los pesticidas de la matriz, sobre todo en matrices grasas como las aceitunas. Por ello, se ha desarrollado un nuevo método simple, rápido, barato y selectivo para la extracción y cuantificación de los pesticidas más frecuentemente utilizados en el cultivo del olivo, empleando cromatografía líquida de ultra-resolución (UPLC acoplada a espectrometría de masas (MS/MS. Las recuperaciones alcanzadas variaron entre el 73 y 114% obteniendo desviaciones estándar relativas inferiores al 20%. Los límites de detección (LD y cuantificación (LQ fueron

  7. Quantitative determination of sirolimus in dog blood using liquid chromatography-tandem mass spectrometry, and its applications to pharmacokinetic studies.

    Science.gov (United States)

    Lee, Jong-Hwa; Cha, Kwang-Ho; Cho, Wonkyung; Park, Junsung; Park, Hee Jun; Cho, Youngseok; Hwang, Sung-Joo

    2010-12-01

    A rapid, sensitive method of detecting sirolimus in blood was developed and applied in pharmacokinetic studies employing deionized water for hemolysis and a weakly basic mobile phase to enhance chromatographic peak intensity. Dog blood samples were processed via liquid-liquid extraction and the amounts of sirolimus and tacrolimus, an internal standard, were quantified by LC-MS/MS. Specificity, the lower limit of quantification, linearity, accuracy, precision, dilution, recovery, matrix effects, robustness and stability were within the acceptable range for assay validation. The concentration of sirolimus was quantifiable in blood samples for up to 36 h after the dog had received a 3 mg/kg dose of sirolimus. These observations suggest that sirolimus can be detected at low levels in dog blood using a basic mobile phase and metal-free hemolysis. This method is therefore applicable to pharmacokinetic studies in dogs. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  8. Determination of antibiotic residues in southern Baltic Sea sediments using tandem solid-phase extraction and liquid chromatography coupled with tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Grzegorz Siedlewicz

    2016-07-01

    Full Text Available The main objective of this study was to adapt analytical procedures for determining antibiotic residues in solid and aquatic samples to marine sediments and to investigate the occurrence of 9 sulfonamides, trimethoprim and 2 quinolones in southern Baltic Sea sediments. The analytical procedure was applied to sediment samples characterized as sand and silty sand. The validation results showed that a sensitive and efficient method applying tandem solid-phase extraction (SPE and liquid chromatography coupled with tandem mass spectrometry (LC–MS/MS was obtained. Analytes were determined in the lower ng g−1 range with good accuracy and precision. The proposed analytical procedure was applied to the analysis of 13 sediment samples collected from the Baltic Sea along the Polish coast. Concentrations of antibiotic residues in environmental samples were calculated based on external matrix-matched calibration. Residues of nine out of twelve of the above antibiotics were detected in sediment samples in a concentrations of up to 419.2 ng g−1 d.w. (dry weight. Sulfamethoxazole and sulfachloropyridazine were the most frequently detected compounds (58% of the analyzed samples. The occurrence frequency of trimethoprim was 42% and it was always detected simultaneously with sulfamethoxazole. Preliminary studies on the spatial distribution of the analyzed antibiotics indicate a high level of antibiotics occurring in the Pomeranian Bay and close to the mouths of Polish rivers. The study is the first one to demonstrate the occurrence of antibiotic residues in sediments of the Polish coastal area. The obtained results suggest that sediment can be an important secondary source of antibiotic residues in the marine environment.

  9. A high-performance liquid chromatography-tandem mass spectrometry method coupled with protein precipitation for determination of granisetron in human plasma and its application to a comparative pharmacokinetic study.

    Science.gov (United States)

    Zhou, Ying; Jiang, Ji; Hu, Pei; Wang, Hongyun

    2014-12-01

    A rapid, simple and validated method based on liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) has been developed for the determination of granisetron in human plasma. Plasma samples were pre-purified by protein precipitation procedure. The chromatographic separation was achieved with Synergi Polar-RP (75 × 2 mm, 4 µm) column using a mixture of 5 mm pH4.0 ammonium formate and methanol (300:316, v/v) under isocratic conditions at a flow rate of 0.3 mL/min. The detection was performed on a triple quadrupole tandem mass spectrometer in multiple reaction monitoring mode using positive electrospray ionization. The analysis time was about 2.5 min. The method was fully validated over the concentration range 0.1-10 ng/mL. The lower limit of quantification was 0.1 ng/mL. Inter- and intra-batch precision was granisetron in Chinese healthy subjects. Copyright © 2014 John Wiley & Sons, Ltd.

  10. Quantification of citalopram or escitalopram and their demethylated metabolites in neonatal hair samples by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Frison, Giampietro; Favretto, Donata; Vogliardi, Susanna; Terranova, Claudio; Ferrara, Santo Davide

    2008-08-01

    Citalopram and escitalopram are highly selective serotonin reuptake inhibitors widely used in the treatment of depression. They exhibit adverse drug reactions and side effects, however, and the development of specific methods for their determination is of great interest in clinical and forensic toxicology. A liquid chromatography-tandem mass spectrometry method has been developed and validated for the assay of citalopram, escitalopram, and their demethylated metabolites in 10-mg hair samples. The analytes were extracted by incubation in methanol and liquid/liquid extraction with diethyl ether/dichloromethane. Gradient elution on a narrow bore C18 column was realized using clomipramine-d3 as an internal standard. Positive ion electrospray ionization and tandem mass spectrometry determination by collision-induced dissociation were performed in an ion trap mass spectrometer. The method exhibited a linear range of 25 to 2000 pg/mg, a quantification limit of 25 pg/mg for all analytes, relative standard deviations in the range of 12.10 to 9.80 (intraassay), and 13.80 to 11.78 (interassay), and accuracies (as percent recovery of the spiked standards) in the range of 90% to 110%; it was applied to the determination of citalopram and escitalopram and their metabolites in hair samples of two newborns to document their in utero exposure to the drugs. The method proved suitable for neonatal hair analysis of citalopram or escitalopram and was applied to two real cases of gestational exposure.

  11. Electrospray[+] tandem quadrupole mass spectrometry in the elucidation of ergot alkaloids chromatographed by HPLC: screening of grass or forage samples for novel toxic compounds.

    Science.gov (United States)

    Lehner, Andreas F; Craig, Morrie; Fannin, Neil; Bush, Lowell; Tobin, Tom

    2005-11-01

    Ergot alkaloids are mycotoxins generated by grass and grain pathogens such as Claviceps, for example. Ergot alkaloid-poisoning syndromes, such as tall fescue toxicosis from endophyte-infected tall fescue grass, are important veterinary problems for cattle, horses, sheep, pigs and chickens, with consequent impact on food, meat and dairy industries. Damage to livestock is of the order of a billion dollars a year in the United States alone. HPLC with UV and fluorescence detection are the predominant means of ergot alkaloid determination, with focus on quantitation of the marker compound ergovaline, although ELISA methods are undergoing investigation. These techniques are excellent for rapid detection, but of poor specificity in defining new or poorly characterized ergot alkaloids and related compounds. This paper demonstrates the facility of using electrospray(+) mass spectrometry with multiple reaction monitoring (MRM) detection during chromatographic examination of ergot alkaloid standards of lysergic acid, lysergol, ergonovine, ergovaline, ergotamine, ergocornine, ergocryptine and ergocrystine by HPLC. Ergoline-8 position epimers could be separated on the gradient HPLC system for ergocornine, ergocrystine and ergonovine and appeared as shoulders for ergotamine and ergovaline; epimers generally showed different patterns of relative intensity for specific MRM transitions. There was reasonable correspondence between retention of standards on the 2-mm ESI(+)MS phenyl-hexyl-based reverse phase column and those on the 4-mm C18-based column. Since up to 10% of clinical cases involving toxin exposure display unidentified chromatographic peaks, 11 samples of feed components associated with such cases were studied with developed MRM methods to attempt elucidation of crucial components if possible. Ergotamine appeared in all, ergovaline appeared in five and ergocornine appeared in six; ergonovine, ergocryptine, ergocrystine and lysergol also appeared in several. In addition

  12. Quantitation of anacetrapib, stable-isotope labeled-anacetrapib (microdose), and four metabolites in human plasma using liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Chavez-Eng, C M; Lutz, R W; Li, H; Goykhman, D; Bateman, K P; Woolf, E

    2016-02-01

    An ultra-high performance liquid chromatography/tandem mass spectrometry (UPLC-MS/MS) method for the simultaneous determination of (4S,5R)-5-[3,5-bis (trifluoromethyl)phenyl]-3-{[4'-fluoro-5'-isopropyl-2'-methoxy-4-(trifluoromethyl)biphenyl-2-yl] methyl}-4-methyl-1,3-oxazolidin-2-one (anacetrapib, I) and [(13)C5(15)N]-anacetrapib, II in human plasma has been developed to support a clinical study to determine the absolute bioavailability of I. The analytes and the stable-isotope labeled internal standard ([(13)C7(15)N(2)H7]-anacetrapib, III) were extracted from 100μL of human plasma by liquid-liquid extraction using 20/80 isopropyl alcohol/hexane (v/v). The chromatographic separation of the analytes was achieved using Waters BEH Shield RP 18 (50×2.1mm×1.7μm) column and mobile phase gradient of 0.1% formic acid in water (Solvent A) and 0.1% formic acid in acetonitrile (Solvent B) at 0.6mL/min flow rate. The MS/MS detection was performed on AB Sciex 5000 or AB 5500 in positive electrospray ionization mode, operated in selected reaction monitoring mode. The assay was validated in the concentration range 1-2000ng/mL for I; and a lower curve range, 0.025-50ng/mL for II. In addition to the absolute bioavailability determination, it was desired to better elucidate the pharmacokinetic behavior of several hydroxylated metabolites of I. Toward this end, two exploratory assays for the hydroxy metabolites of I were qualified in the concentration range 0.5-500ng/mL. All metabolites were separated on a Supelco Ascentis Express Phenyl-Hexyl (50×2.1mm, 2.7μm) column. Metabolite M4 was analyzed in the negative mode with a mobile phase consisting of a gradient mixture of water (A) and acetonitrile (B). The other three metabolites, M1-M3 were analyzed in the positive mode using a mobile phase gradient of water with 0.1% formic acid (A) and acetonitrile with 0.1% formic acid (B). The assays were utilized to support a clinical study in which a microdosing approach was used to

  13. Method development for the determination of 24S-hydroxycholesterol in human plasma without derivatization by high-performance liquid chromatography with tandem mass spectrometry in atmospheric pressure chemical ionization mode.

    Science.gov (United States)

    Sugimoto, Hiroshi; Kakehi, Masaaki; Satomi, Yoshinori; Kamiguchi, Hidenori; Jinno, Fumihiro

    2015-10-01

    We developed a highly sensitive and specific high-performance liquid chromatography with tandem mass spectrometry method with an atmospheric pressure chemical ionization interface to determine 24S-hydroxycholesterol, a major metabolite of cholesterol formed by cytochrome P450 family 46A1, in human plasma without any derivatization step. Phosphate buffered saline including 1% Tween 80 was used as the surrogate matrix for preparation of calibration curves and quality control samples. The saponification process to convert esterified 24S-hydroxycholesterol to free sterols was optimized, followed by liquid-liquid extraction using hexane. Chromatographic separation of 24S-hydroxycholesterol from other isobaric endogenous oxysterols was successfully achieved with gradient mobile phase comprised of 0.1% propionic acid and acetonitrile using L-column2 ODS (2 μm, 2.1 mm id × 150 mm). This assay was capable of determining 24S-hydroxycholesterol in human plasma (200 μL) ranging from 1 to 100 ng/mL with acceptable intra- and inter-day precision and accuracy. The potential risk of in vitro formation of 24S-hydroxycholesterol by oxidation from endogenous cholesterol in human plasma was found to be negligible. The stability of 24S-hydroxycholesterol in relevant solvents and human plasma was confirmed. This method was successfully applied to quantify the plasma concentrations of 24S-hydroxycholesterol in male and female volunteers. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Determination of salbutamol and salbutamol glucuronide in human urine by means of liquid chromatography-tandem mass spectrometry

    DEFF Research Database (Denmark)

    Mareck, Ute; Guddat, Sven; Schwenke, Anne

    2012-01-01

    The determination of salbutamol and its glucuronide in human urine following the inhalative and oral administration of therapeutic doses of salbutamol preparations was performed by means of direct urine injection utilizing liquid chromatography-tandem mass spectrometry (LC-MS/MS) and employing d(3...... glucuronide values between 8 and 15 ng/ml. The approach enabled the rapid determination of salbutamol and its glucuronic acid conjugate in human urine and represents an alternative to existing procedures since time-consuming hydrolysis or derivatization steps were omitted. Moreover, the excretion...

  15. Determination of olanzapine in whole blood using simple protein precipitation and liquid chromatography-tandem mass spectrometry

    DEFF Research Database (Denmark)

    Nielsen, Marie Katrine Klose; Johansen, Sys Stybe

    2009-01-01

    A simple, sensitive, and reproducible liquid chromatography-tandem mass spectrometry method has been developed and validated for the quantification of the antipsychotic drug olanzapine in whole blood using dibenzepine as internal standard (IS). After acidic methanol-induced protein precipitation......, and stability. The absolute recovery obtained was 103% for olanzapine and 68% for IS. An LOQ of 0.005 mg/kg olanzapine in whole blood was achieved. Inter- and intraday precision were less than 11% within concentrations from 0.01 to 0.50 mg/kg, and the accuracy ranged from 85 to 115%. The method was subsequently...

  16. Liquid chromatography/tandem mass spectrometry method for quantitative estimation of solutol HS15 and its applications

    OpenAIRE

    Bhaskar, V. Vijaya; Middha, Anil; Srivastava, Pratima; Rajagopal, Sriram

    2015-01-01

    A rapid, sensitive and selective pseudoMRM (pMRM)-based method for the determination of solutol HS15 (SHS15) in rat plasma was developed using liquid chromatography/tandem mass spectrometry (LCâMS/MS). The most abundant ions corresponding to SHS15 free polyethyleneglycol (PEG) oligomers at m/z 481, 525, 569, 613, 657, 701, 745, 789, 833, 877, 921 and 965 were selected for pMRM in electrospray mode of ionization. Purity of the lipophilic and hydrophilic components of SHS15 was estimated using ...

  17. Simultaneous Determination of 25 Common Pharmaceuticals in Whole Blood Using Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry

    DEFF Research Database (Denmark)

    Nielsen, Marie Katrine Klose; Johansen, Sys Stybe

    2012-01-01

    An ultra-performance liquid chromatography-tandem mass spectrometry method was developed and validated for the quantification of 25 common pharmaceuticals in whole blood. The selected pharmaceuticals represent the most frequently detected drugs in our forensic laboratory with basic properties....../kg depending on the analyte. A good linear behavior was achieved for all analytes in the range from LOQ to 1.0 or 2.0 mg/kg blood. The absolute recoveries were between 55-87% for all compounds except norfluoxetine (44%). The method showed acceptable precision and accuracy for almost all analytes. Only unstable...

  18. Quantification of urinary 0,0'-dityrosine, a biomarker for oxidative damage to proteins, by high performance liquid chromatography with triple quadrupole tandem mas spectrometry. A comparison with ion-trap tandem mass spectrometry.

    NARCIS (Netherlands)

    Orhan, H.; Coolen, S.; Meerman, J.H.N.

    2005-01-01

    We recently described an isotope dilution reversed-phase liquid chromatography-atmospheric pressure chemical ionization-ion-trap-tandem mass spectrometry (HPLC-APCI-MS/MS) method for the quantitative determination of oxidized amino acids in human urine, including o,o′-dityrosine, a specific marker

  19. Analysis of carbonyl compounds via headspace solid-phase microextraction with on-fiber derivatization and gas chromatographic-ion trap tandem mass spectrometric determination of their O-(2,3,4,5,6-pentafluorobenzyl)oxime derivatives

    Energy Technology Data Exchange (ETDEWEB)

    Schmarr, Hans-Georg [Dienstleistungszentrum Laendlicher Raum (DLR) Rheinpfalz, Breitenweg 71, D-67435 Neustadt an der Weinstrasse (Germany)], E-mail: hans-georg.schmarr@dlr.rlp.de; Potouridis, Theodoros; Ganss, Sebastian; Sang, Wei; Koepp, Benedikt; Bokuz, Ursula; Fischer, Ulrich [Dienstleistungszentrum Laendlicher Raum (DLR) Rheinpfalz, Breitenweg 71, D-67435 Neustadt an der Weinstrasse (Germany)

    2008-06-09

    An improved method for the analysis of carbonyls is described utilizing a headspace solid-phase microextraction (HS-SPME) step and on-fiber derivatization with O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine (PFBHA) hydrochloride. Thermal desorption of the oxime derivatives formed on the fiber is followed by gas chromatographic separation coupled to an ion trap tandem mass spectrometer (GC-ITMS). Selecting specific fragment ions within the electron ionization (EI{sup +}) mass spectra of these oxime derivatives as precursor ions for MS-MS fragmentation provides a suitable method for the target analysis of individual carbonyl classes, such as alkanals, (E)-2-alkenals, (E,E)-2,4-alkadienals, and others. Retention indices on polar as well as on apolar stationary phases along with EI{sup +} mass spectra patterns are presented for a large set of oxime derivatives, giving valuable information needed for unambiguous assignment of substances in complex sample matrices. The fast sample preparation and derivatization step via HS-SPME can be automated and is applicable to a variety of biological samples and foodstuffs, allowing rapid and sensitive screening analyses of important aldehydic biomarkers and aroma active compounds.

  20. Development of a high performance liquid chromatography tandem mass spectrometry based analysis for the simultaneous quantification of various Alternaria toxins in wine, vegetable juices and fruit juices.

    Science.gov (United States)

    Zwickel, Theresa; Klaffke, Horst; Richards, Keith; Rychlik, Michael

    2016-07-15

    An analytical method based on high performance liquid chromatography (HPLC) and tandem mass spectrometry (MS/MS) detection for the simultaneous quantification of 12 Alternaria toxins in wine, vegetable juices and fruit juices was developed. Excellent chromatographic performance was demonstrated for tenuazonic acid (TeA) in a multi-analyte method. This comprehensive study is also the first to report the determination of TeA, alternariol (AOH), alternariol monomethyl ether (AME), tentoxin (TEN) and altenuene (ALT), altertoxin I (ATX-I), altertoxin II (ATX-II), altenuisol (ATL), iso-altenuene (isoALT), altenuic acid III (AA-III) and the AAL toxins TB1 und TB2 in samples from the German market. Several types of HPLC columns were tested for the liquid chromatographic separation of the toxins of interest that widely differ in their polarities. The focus was on gaining suitable retention while avoiding derivatization steps especially for TeA and AA-III. Three atmospheric pressure ionization techniques used with liquid chromatography (electrospray, chemical and photo ionization) were tested to obtain the best selectivity and sensitivity. Samples were diluted with sodium hydrogen carbonate buffer and extracted on a diatomaceous earth solid phase extraction cartridge. Method validation was carried out by using tomato juice, citrus juice and white wine as blank matrices. Limits of detection ranged from 0.10 to 0.59μgL(-1) and limits of quantification ranged from 0.4-3.1μgL(-1) depending on the toxin and matrix. Recoveries were around 100±9% for all toxins except stemphyltoxin III (STTX-III) and altenusin (ALS) due to instability during sample clean up. Matrix-induced effects leading to ion suppression especially for ATX-I, ATX-II and AA-III were investigated. Relative standard deviations of repeatability (RSDr) and intermediate reproducibility (RSDR) were ≤9.3 and ≤17.1, respectively, for the toxins in different matrices at levels of 5 and 30μgL(-1). Finally, 103

  1. Alternative solvent-based methyl benzoate vortex-assisted dispersive liquid-liquid microextraction for the high-performance liquid chromatographic determination of benzimidazole fungicides in environmental water samples.

    Science.gov (United States)

    Santaladchaiyakit, Yanawath; Srijaranai, Supalax

    2014-11-01

    Vortex-assisted dispersive liquid-liquid microextraction using methyl benzoate as an alternative extraction solvent for extracting and preconcentrating three benzimidazole fungicides (i.e., carbendazim, thiabendazole, and fluberidazole) in environmental water samples before high-performance liquid chromatographic analysis has been developed. The selected microextraction conditions were 250 μL of methyl benzoate containing 300 μL of ethanol, 1.0% w/v sodium acetate, and vortex agitation speed of 2100 rpm for 30 s. Under optimum conditions, preconcentration factors were 14.5-39.0 for the target fungicides. Limits of detection were obtained in the range of 0.01-0.05 μg/L. The proposed method was then applied to surface water samples and the recovery evaluations at three spiked concentration levels of 5, 30, and 50 μg/L were obtained in the range of 77.4-110.9% with the relative standard deviation water samples. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. RUTHENIUM-CATALYZED TANDEM OLEFIN MIGRATION-ALDOL AND MANNICH-TYPE REACTIONS IN IONIC LIQUID.

    Science.gov (United States)

    In the presence of a catalytic amount of RuCl2(PPh3)3, a cross-coupling of 3-buten-2-ol with aldehydes and imines was developed via a tandem olefin migration--aldol--Mannich reaction in bmim[PF6]. With In(OAc)3 as a co-catalyst, a-vinylbenzyl alcohol and aldehydes underwent sim...

  3. Heat-pipe liquid-pool-blanket concept for the Tandem Mirror Reactor

    International Nuclear Information System (INIS)

    Hoffman, M.A.; Werner, R.W.; Johnson, G.L.

    1981-01-01

    The blanket concept for the tandem mirror reactor described in this paper was developed to produce the medium temperature heat (approx. 850 to 950 K) for the General Atomic sulfur-iodine thermochemical process for producing hydrogen. This medium temperature heat from the blanket constitutes about 81% of the total power output of the fusion reactor

  4. High performance liquid chromatographic separation of thirteen drugs collected in Chinese Pharmacopoeia 2010(Ch.P2010 on cellulose ramification chiral stationary phase

    Directory of Open Access Journals (Sweden)

    Ying Zhou

    2012-02-01

    Full Text Available The enantiomers separation of thirteen drugs collected in Ch.P2010 was performed on chiral stationary phase of cellulose ramification (chiralpak OD and chiralpak OJ by high performance liquid chromatographic (HPLC methods, which included ibuprofen (C1, ketoprofen (C2, nitrendipine (C3, nimodipine (C4, felodipine (C5, omeprazole (C6, praziquantel (C7, propranolol hydrochloride (C8, atenolol (C9, sulpiride (C10, clenbuterol hydrochloride (C11, verapamil hydrochloride (C12, and chlorphenamine maleate (C13. The mobile phase consisted of isopropanol and n-hexane. The detection wavelength was set at 254 nm and the flow rate was 0.7 mL/min. The enantiomers separation of these thirteen racemates on chiralpak OD column and chiralpak OJ column was studied, while the effects of proportion of organic additives, alcohol displacer and temperature on the separation were studied. And the mechanism of some of racemates was discussed. The results indicated that thirteen chiral drugs could be separated on chiral stationary phase of cellulose ramification in normal phase chromatographic system. The chromatographic retention and resolution of enantiomers could be adjusted by factors including column temperature and the concentration of alcohol displacer and organic alkaline modifier in mobile phase. It was shown that the resolution was improved with reducing concentration of alcohol displacer. When concentration of organic alkaline modifier was 0.2% (v/v, the resolution and the peak shape were fairly good. Most racemates mentioned above had better resolution at column temperature of 25 °C. When racemates were separated, the temperature should be kept so as to obtain stable separation results. Keywords: HPLC, Chiral stationary phase, Optical enantiomers, Cellulose ramification

  5. [Development of an automatic vacuum liquid chromatographic device and its application in the separation of the components from Schisandra chinensis (Turz) Baill].

    Science.gov (United States)

    Zhu, Jingbo; Liu, Baoyue; Shan, Shibo; Ding, Yanl; Kou, Zinong; Xiao, Wei

    2015-08-01

    In order to meet the needs of efficient purification of products from natural resources, this paper developed an automatic vacuum liquid chromatographic device (AUTO-VLC) and applied it to the component separation of petroleum ether extracts of Schisandra chinensis (Turcz) Baill. The device was comprised of a solvent system, a 10-position distribution valve, a 3-position changes valve, dynamic axis compress chromatographic columns with three diameters, and a 10-position fraction valve. The programmable logic controller (PLC) S7- 200 was adopted to realize the automatic control and monitoring of the mobile phase changing, column selection, separation time setting and fraction collection. The separation results showed that six fractions (S1-S6) of different chemical components from 100 g Schisandra chinensis (Turcz) Baill. petroleum ether phase were obtained by the AUTO-VLC with 150 mm diameter dynamic axis compress chromatographic column. A new method used for the VLC separation parameters screened by using multiple development TLC was developed and confirmed. The initial mobile phase of AUTO-VLC was selected by taking Rf of all the target compounds ranging from 0 to 0.45 for fist development on the TLC; gradient elution ratio was selected according to k value (the slope of the linear function of Rf value and development times on the TLC) and the resolution of target compounds; elution times (n) were calculated by the formula n ≈ ΔRf/k. A total of four compounds with the purity more than 85% and 13 other components were separated from S5 under the selected conditions for only 17 h. Therefore, the development of the automatic VLC and its method are significant to the automatic and systematic separation of traditional Chinese medicines.

  6. Simultaneous detection of five different 2-hydroxyethyl-DNA adducts formed by ethylene oxide exposure, using a high-performance liquid chromatography/electrospray ionisation tandem mass spectrometry assay.

    Science.gov (United States)

    Tompkins, Elaine M; Jones, Donald J L; Lamb, John H; Marsden, Debbie A; Farmer, Peter B; Brown, Karen

    2008-01-01

    A method has been developed for the simultaneous detection and quantitation of five different 2-hydroxyethyl-DNA (HE-DNA) adducts that could be formed as a result of exposure to ethylene oxide (EO). In addition to the major N7-HE-guanine (N7-HEG) adducts this assay can also measure the less prevalent but potentially more biologically significant N1-HE-2'-deoxyadenosine (N1-HEdA), O(6)-HE-2'-deoxyguanosine (O(6)-HEdG), N(6)-HE-2'-deoxyadenosine (N(6)-HEdA) and N3-HE-2'-deoxyuridine adducts (N3-HEdU). The method involves the isolation of HE adducts from the unmodified nucleosides by either neutral thermal hydrolysis or enzymatic digestion, followed by high-performance liquid chromatographic (HPLC) purification, before detection and quantification by liquid chromatography tandem mass spectrometry (LC/MS/MS) using selective reaction monitoring (SRM). The limits of detection were in the range 0.5-25 fmol for each individual adduct, making this one of the most sensitive assays available for the detection of N7-HEG. To illustrate the possible applications of the assay, it has been employed in the measurement of endogenous/background and EO-induced HE adducts in a variety of DNA samples.

  7. Liquid chromatography-tandem mass spectrometry detection of the quaternary ammonium compound mebezonium as an active ingredient in t61.

    Science.gov (United States)

    Kirschbaum, Katrin M; Grellner, Wolfgang; Rochholz, Gertrud; Musshoff, Frank; Madea, Burkhard

    2011-03-01

    Quaternary ammonium compounds pose an analytical challenge. Mebezonium, a muscle-relaxing agent contained in veterinary euthanasia solution T61, was analyzed in body fluids, organs, and injection sites of a veterinarian by liquid chromatography-tandem mass spectrometry (LC-MS-MS) method. Additionally, embutramide and tetracaine, which are two other active ingredients contained in T61, methadone, xylazine, and analgesics were detected by LC-MS-MS and high-performance liquid chromatography-ultraviolet detection methods. For detection of mebezonium a solid-phase extraction (SPE) combined with ionpairing reagent heptafluorobutyric acid was developed. Separation was achieved on Phenomenex Synergi Hydro RP C(18) column combined with ammonium formate buffer and acetonitrile (pH 3.5). To enrich other drugs, liquid-liquid extraction procedures were used. Most of these drugs were separated on a Restek Allure PFP Propyl column using the mentioned mobile phase. Mebezonium and embutramide were detected in femoral vein serum in concentrations of 10.9 and 2.0 mg/L, respectively. The concentration of xylazine and methadone in serum was 2.0 and 0.4 mg/L, respectively. The LC-MS-MS method with SPE combined with an ion-pairing reagent allowed the quantitation of mebezonium. Methadone was detected in toxic concentrations and was, in combination with xylazine and T61, considered to be the cause of death.

  8. Chemical modification of DNA: Molecular specificity studied by tandem mass spectrometry and liquid chromatography

    International Nuclear Information System (INIS)

    Chang, Ching-jer; Cooks, R.G.; Chae, Whi-Gun; Wood, J.M.

    1989-01-01

    Chemical modifications of DNA in vitro could be directly studied by C-13 NMR and P-31 NMR, which eliminated all degradation and separation processes. The prospects of utilized the NMR method in the in vitro experiments are limited because of the inherent low sensitivity of NMR and low level of DNA modification. We have developed a reverse-phase ion-paired HPLC method to study DNA modifications by methylating agents. The structural specificity of HPLC is significantly enhanced by conjunction with the specificity of enzymic transformations. The HPLC studies have also revealed the limitation of HPLC method for simultaneous determination of many minor modified nucleosides. This problem has been overcome by tandem mass spectrometry. In conjunction with the resolving power of HPLC in separating isomers, desorption chemical ionization tandem mass spectrometry has been utilized in the determination of the modified nucleosides at the picomole level using stable-isotope labeled compounds as internal references

  9. Chromatographic background drift correction coupled with parallel factor analysis to resolve coelution problems in three-dimensional chromatographic data: quantification of eleven antibiotics in tap water samples by high-performance liquid chromatography coupled with a diode array detector.

    Science.gov (United States)

    Yu, Yong-Jie; Wu, Hai-Long; Fu, Hai-Yan; Zhao, Juan; Li, Yuan-Na; Li, Shu-Fang; Kang, Chao; Yu, Ru-Qin

    2013-08-09

    Chromatographic background drift correction has been an important field of research in chromatographic analysis. In the present work, orthogonal spectral space projection for background drift correction of three-dimensional chromatographic data was described in detail and combined with parallel factor analysis (PARAFAC) to resolve overlapped chromatographic peaks and obtain the second-order advantage. This strategy was verified by simulated chromatographic data and afforded significant improvement in quantitative results. Finally, this strategy was successfully utilized to quantify eleven antibiotics in tap water samples. Compared with the traditional methodology of introducing excessive factors for the PARAFAC model to eliminate the effect of background drift, clear improvement in the quantitative performance of PARAFAC was observed after background drift correction by orthogonal spectral space projection. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. A simple high-performance liquid chromatographic method for the estimation of boswellic acids from the market formulations containing Boswellia serrata extract.

    Science.gov (United States)

    Shah, Shailesh A; Rathod, Ishwarsinh S; Suhagia, Bhanubhai N; Pandya, Saurabh S; Parmar, Vijay K

    2008-09-01

    A simple, rapid, and reproducible reverse-phase high-performance liquid chromatographic method is developed for the estimation of boswellic acids, the active constituents in Boswellia serrata oleo-gum resin. The chromatographic separation is performed using a mobile phase consisting of acetonitrile-water (90:10, % v/v) adjusted to pH 4 with glacial acetic acid on a Kromasil 100 C18 analytical column with flow rate of 2.0 mL/min and detection at 260 nm. The elution times are 4.30 and 7.11 min for 11-keto beta-boswellic acid (11-KBA) and 3-acetyl 11-keto beta-boswellic acid (A-11-KBA), respectively. The calibration curve is linear in the 11.66-58.30 microg/mL and 6.50-32.50 microg/mL range for 11-KBA and A-11-KBA, respectively. The limits of detection are 2.33 microg/mL and 1.30 microg/mL for 11-KBA and A-11-KBA, respectively. The mean recoveries are 98.24% to 104.17% and 94.12% to 105.92% for 11-KBA and A-11-KBA, respectively. The inter- and intra-day variation coefficients are less than 5%. The present method is successfully applied for the estimation of boswellic acids from the market formulations containing Boswellia serrata extract.

  11. Liquid chromatographic method for the simultaneous determination of cefalexin and trimethoprim in dog plasma and application to the pharmacokinetic studies of a coformulated preparation.

    Science.gov (United States)

    Qi, Meiling; Wang, Peng; Sun, Ping; Liu, Xia

    2006-03-07

    A liquid chromatographic method is described for the simultaneous determination of cefalexin and trimethoprim in dog plasma. A simple protein precipitation procedure was adopted for the sample preparation with satisfactory extraction recoveries for both analytes. Chromatographic separation of the analytes was achieved on a C(18) column using a mixture of 2 mol/l formate buffer (pH 3.5), methanol and acetonitrile (22:7:7, v/v/v) containing a 0.002 mol/l sodium dodecyl sulfate as mobile phase and detection was performed at 240 nm. The linearity was obtained over the concentration ranges of 1.0-100.0 microg/ml for cefalexin and 0.5-50.0 microg/ml for trimethoprim. For each level of QC samples including the lower limit of quantification, both inter- and intra-day precisions (R.S.D.) were trimethoprim, and accuracy (RE) was -1.4% for cefalexin and -3.0% for trimethoprim. The present LC method was successfully applied to the pharmacokinetic studies of coformulated cefalexin dispersible tablets after oral administration to beagle dogs.

  12. Study and ICH validation of a reverse-phase liquid chromatographic method for the quantification of the intact monoclonal antibody cetuximab

    Directory of Open Access Journals (Sweden)

    Antonio Martínez-Ortega

    2016-04-01

    Full Text Available Cetuximab (CTX is a potent chimeric mouse/human monoclonal antibody (mAb approved worldwide for treatment of metastatic colorectal cancer. Among the various biological and physical analyses performed for full study on this biopharmaceutic, the determination of the concentration preparations throughout manufacturing and subsequent handling in hospital is particularly relevant. In the present work, the study and validation of a method for quantifying intact CTX by reverse-phase high-performance liquid chromatography with diode array detection ((RPHPLC/DAD is presented. With that end, we checked the performance of a chromatographic method for quantifying CTX and conducted a study to validate the method as stability-indicating in accordance with the International Conference on Harmonization guidelines (ICH for biotechnological drugs; therefore, we evaluated linearity, accuracy, precision, detection and quantification limits, robustness and system suitability. The specificity of the method and the robustness of the mAb formulation against external stress factors were estimated by comprehensive chromatographic analysis by subjecting CTX to several informative stress conditions. As demonstrated, the method is rapid, accurate, and reproducible for CTX quantification. It was also successfully used to quantify CTX in a long-term stability study performed under hospital conditions.

  13. A reversed phase high performance liquid chromatography method for the determination of fumonisins B1 and B2 in food and feed using monolithic column and positive confirmation by liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Khayoon, Wejdan Shakir; Saad, Bahruddin; Salleh, Baharuddin; Ismail, Nor Azliza; Abdul Manaf, Normaliza Hj; Abdul Latiff, Aishah

    2010-10-29

    The development of a reversed phase high performance liquid chromatography fluorescence method for the determination of the mycotoxins fumonisin B(1) and fumonisin B(2) by using silica-based monolithic column is described. The samples were first extracted using acetonitrile:water (50:50, v/v) and purified by using a C(18) solid phase extraction-based clean-up column. Then, pre-column derivatization for the analyte using ortho-phthaldialdehyde in the presence of 2-mercaptoethanol was carried out. The developed method involved optimization of mobile phase composition using methanol and phosphate buffer, injection volume, temperature and flow rate. The liquid chromatographic separation was performed using a reversed phase Chromolith(®) RP-18e column (100 mm × 4.6 mm) at 30 °C and eluted with a mobile phase of a mixture of methanol and phosphate buffer pH 3.35 (78:22, v/v) at a flow rate of 1.0 mL min(-1). The fumonisins separation was achieved in about 4 min, compared to approximately 20 min by using a C(18) particle-packed column. The fluorescence excitation and emission were at 335 nm and 440 nm, respectively. The limits of detections were 0.01-0.04 μg g(-1) fumonisin B(1) and fumonisin B(2), respectively. Good recoveries were found for spiked samples (0.1, 0.5, 1.5 μg g(-1) fumonisins B(1) and B(2)), ranging from 84.0 to 106.0% for fumonisin B(1) and from 81.0 to 103.0% for fumonisin B(2). Fifty-three samples were analyzed including 39 food and feeds and 14 inoculated corn and rice. Results show that 12.8% of the food and feed samples were contaminated with fumonisin B(1) (range, 0.01-0.51 μg g(-1)) and fumonisin B(2) (0.05 μg g(-1)). The total fumonisins in these samples however, do not exceed the legal limits established by the European Union of 0.8 μg g(-1). Of the 14 inoculated samples, 57.1% contained fumonisin B(1) (0.16-41.0 μg g(-1)) and fumonisin B(2) (range, 0.22-50.0 μg g(-1)). Positive confirmation of selected samples was carried out using

  14. Systematic evaluation of commercially available ultra-high performance liquid chromatography columns for drug metabolite profiling: optimization of chromatographic peak capacity.

    Science.gov (United States)

    Dubbelman, Anne-Charlotte; Cuyckens, Filip; Dillen, Lieve; Gross, Gerhard; Hankemeier, Thomas; Vreeken, Rob J

    2014-12-29

    The present study investigated the practical use of modern ultra-high performance liquid chromatography (UHPLC) separation techniques for drug metabolite profiling, aiming to develop a widely applicable, high-throughput, easy-to-use chromatographic method, with a high chromatographic resolution to accommodate simultaneous qualitative and quantitative analysis of small-molecule drugs and metabolites in biological matrices. To this end, first the UHPLC system volume and variance were evaluated. Then, a mixture of 17 drugs and various metabolites (molecular mass of 151-749Da, logP of -1.04 to 6.7), was injected on six sub-2μm particle columns. Five newest generation core shell technology columns were compared and tested against one column packed with porous particles. Two aqueous (pH 2.7 and 6.8) and two organic mobile phases were evaluated, first with the same flow and temperature and subsequently at each column's individual limit of temperature and pressure. The results demonstrated that pre-column dead volume had negligible influence on the peak capacity and shape. In contrast, a decrease in post-column volume of 57% resulted in a substantial (47%) increase in median peak capacity and significantly improved peak shape. When the various combinations of stationary and mobile phases were used at the same flow rate (0.5mL/min) and temperature (45°C), limited differences were observed between the median peak capacities, with a maximum of 26%. At higher flow though (up to 0.9mL/min), a maximum difference of almost 40% in median peak capacity was found between columns. The finally selected combination of solid-core particle column and mobile phase composition was chosen for its selectivity, peak capacity, wide applicability and peak shape. The developed method was applied to rat hepatocyte samples incubated with the drug buspirone and demonstrated to provide a similar chromatographic resolution, but a 6 times higher signal-to-noise ratio than a more traditional UHPLC

  15. Nanofluid of zinc oxide nanoparticles in ionic liquid for single drop liquid microextraction of fungicides in environmental waters prior to high performance liquid chromatographic analysis.

    Science.gov (United States)

    Amde, Meseret; Tan, Zhi-Qiang; Liu, Rui; Liu, Jing-Fu

    2015-05-22

    Using a nanofluid obtained by dispersing ZnO nanoparticles (ZnO NPs) in 1-hexyl-3-methylimidazolium hexafluorophosphate, new single drop microextraction method was developed for simultaneous extraction of three fungicides (chlorothalonil, kresoxim-methyl and famoxadone) in water samples prior to their analysis by high performance liquid chromatography (HPLC-VWD). The parameters affecting the extraction efficiency such as amount of ZnO NPs in the nanofluid, solvent volume, extraction time, stirring rate, pH and ionic strength of the sample solution were optimized. Under the optimized conditions, the limits of detection were in the range of 0.13-0.19ng/mL, the precision of the method assessed with intra-day and inter-day relative standard deviations were water samples including lake water, river water, as well as effluent and influent of wastewater treatment plant, with recoveries in the range of 74.94-96.11% at 5ng/mL spiking level. Besides to being environmental friendly, the high enrichment factor and the data quality obtained with the proposed method demonstrated its potential for application in multi residue analysis of fungicides in actual water samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Determination of sedative hypnotics in sewage sludge by pressurized liquid extraction with high-performance liquid chromatography and tandem mass spectrometry.

    Science.gov (United States)

    Arbeláez, Paula; Granados, Judith; Borrull, Francesc; Marcé, Rosa Maria; Pocurull, Eva

    2014-12-01

    This paper describes a method for the determination of eight sedative hypnotics (benzodiazepines and barbiturates) in sewage sludge using pressurized liquid extraction and liquid chromatography with tandem mass spectrometry. Pressurized liquid extraction operating conditions were optimized and maximum recoveries were reached using methanol under the following operational conditions: 100ºC, 1500 psi, extraction time of 5 min, one extraction cycle, flush volume of 60% and purge time of 120 s. Pressurized liquid extraction recoveries were higher than 88% for all the compounds except for carbamazepine (55%). The repeatability and reproducibility between days, expressed as relative standard deviation (n = 5), were lower than 6 and 10%, respectively. The detection limits for all compounds were lower than 12.5 μg/kg of dry weight. The method was applied to determine benzodiazepines and barbiturates in sewage sludge from urban sewage treatment plants, and carbamazepine showed the highest concentration (7.9-18.9 μg/kg dry weight). © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Simultaneous determination of three pesticides and their metabolites in unprocessed foods using ultraperformance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Rong, Lili; Wu, Xiaohu; Xu, Jun; Dong, Fengshou; Liu, Xingang; Pan, Xinglu; Du, Pengqiang; Wei, Dongmei; Zheng, Yongquan

    2018-02-01

    We have developed a rapid, multi-compound analytical method for measuring residues of the pesticides thiamethoxam and its metabolite, clothianidin; fipronil and its three metabolites, fipronil sulfone, fipronil sulfide, and fipronil desulfinyl; and pyraclostrobin in unprocessed foods (rice, corn, cucumbers, tomatoes, apples, and bananas) by ultra-performance liquid chromatography coupled to tandem mass spectrometry. Acetonitrile was used as the extraction solvent, and an octadecylsilane-dispersive SPE was used to clean up the analytes, which were then separated through a UPLC HSS T3 column connected to a tandem mass spectrometer via an electrospray ionisation source. The linearity of this method for the target analytes was excellent (R 2  ≥0.990) in the concentration range of 5-1000 μg kg -1 . The average recoveries of the seven compounds at concentrations of 10, 100, and 1000 μg kg -1 from six spiked matrix samples ranged from 73.6 to 110.6%, all with RSD values of ≤19.7%. The limit of quantification was 10 μg kg -1 . The method validated the effectiveness of the method for routine monitoring the residue of these pesticides and their metabolites in foods.

  18. [Qualitative and quantitative analysis of amygdalin and its metabolite prunasin in plasma by ultra-high performance liquid chromatography-tandem quadrupole time of flight mass spectrometry and ultra-high performance liquid chromatography-tandem triple quadrupole mass spectrometry].

    Science.gov (United States)

    Gao, Meng; Wang, Yuesheng; Wei, Huizhen; Ouyang, Hui; He, Mingzhen; Zeng, Lianqing; Shen, Fengyun; Guo, Qiang; Rao, Yi

    2014-06-01

    A method was developed for the determination of amygdalin and its metabolite prunasin in rat plasma after intragastric administration of Maxing shigan decoction. The analytes were identified by ultra-high performance liquid chromatography-tandem quadrupole time of flight mass spectrometry and quantitatively determined by ultra-high performance liquid chromatography-tandem triple quadrupole mass spectrometry. After purified by liquid-liquid extraction, the qualitative analysis of amygdalin and prunasin in the plasma sample was performed on a Shim-pack XR-ODS III HPLC column (75 mm x 2.0 mm, 1.6 microm), using acetonitrile-0.1% (v/v) formic acid aqueous solution. The detection was performed on a Triple TOF 5600 quadrupole time of flight mass spectrometer. The quantitative analysis of amygdalin and prunasin in the plasma sample was performed by separation on an Agilent C18 HPLC column (50 mm x 2.1 mm, 1.7 microm), using acetonitrile-0.1% (v/v) formic acid aqueous solution. The detection was performed on an AB Q-TRAP 4500 triple quadrupole mass spectrometer utilizing electrospray ionization (ESI) interface operated in negative ion mode and multiple-reaction monitoring (MRM) mode. The qualitative analysis results showed that amygdalin and its metabolite prunasin were detected in the plasma sample. The quantitative analysis results showed that the linear range of amygdalin was 1.05-4 200 ng/mL with the correlation coefficient of 0.999 0 and the linear range of prunasin was 1.25-2 490 ng/mL with the correlation coefficient of 0.997 0. The method had a good precision with the relative standard deviations (RSDs) lower than 9.20% and the overall recoveries varied from 82.33% to 95.25%. The limits of detection (LODs) of amygdalin and prunasin were 0.50 ng/mL. With good reproducibility, the method is simple, fast and effective for the qualitative and quantitative analysis of the amygdalin and prunasin in plasma sample of rats which were administered by Maxing shigan decoction.

  19. SIMULTANEOUS ANALYSIS OF AZIDOTHYMIDINE AND ITS MONOPHOSPHATE, DIPHOSPHATE AND TRIPHOSPHATE DERIVATIVES IN BIOLOGICAL-FLUIDS, TISSUE AND CULTURED-CELLS BY A RAPID HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD

    NARCIS (Netherlands)

    MOLEMA, G; JANSEN, RW; Visser, Jan; MEIJER, DKF

    1992-01-01

    A rapid high-performance liquid chromatographic (HPLC) method for the simultaneous analysis of the antiviral drug azidothymidine (AZT), AZT monophosphate, AZT diphosphate and AZT triphosphate, with ultraviolet detection in the nanomolar range, is described. Determination of these compounds in vitro

  20. Quantitation of iothalamate in urine and plasma using liquid chromatography electrospray tandem mass spectrometry (HPLC-ESI-MS/MS).

    Science.gov (United States)

    Molinaro, Ross J; Ritchie, James C

    2010-01-01

    The following chapter describes a method to measure iothalamate in plasma and urine samples using high performance liquid chromatography combined with electrospray positive ionization tandem mass spectrometry (HPLC-ESI-MS/MS). Methanol and water are spiked with the internal standard (IS) iohexol. Iothalamate is isolated from plasma after IS spiked methanol extraction and from urine by IS spiked water addition and quick-spin filtration. The plasma extractions are dried under a stream of nitrogen. The residue is reconstituted in ammonium acetate-formic acid-water. The reconstituted plasma and filtered urine are injected into the HPLC-ESI-MS/MS. Iothalamate and iohexol show similar retention times in plasma and urine. Quantification of iothalamate in the samples is made by multiple reaction monitoring using the hydrogen adduct mass transitions, from a five-point calibration curve.

  1. Determination of seven bisphenol analogues in reed and Callitrichaceae by ultra performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Lu, Libin; Yang, Yunjia; Zhang, Jing; Shao, Bing

    2014-03-15

    An analytical procedure was developed to simultaneously determine bisphenol S, bisphenol F, bisphenol B, bisphenol A, bisphenol AF, tetrachlorobisphenol A, and tetrabromobisphenol A in reed and Callitrichaceae. Homogenized samples were extracted with acetonitrile and purified using an ENVI™-Carb cartridge followed by an NH2 cartridge. The analytes were separated and quantified by ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The recoveries at three fortified levels in reed and Callitrichaceae were 57-108% and 68-106%, respectively, with relative standard deviations of no more than 15% (n=6). The method limits of quantification and detection for the seven bisphenol analogues were 0.005-0.500μg/kg and 0.002-0.150μg/kg, respectively. This method was used to analyze the seven compounds in ten reed and Callitrichaceae samples collected from Zhejiang, China. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Simultaneous quantitation of six major quassinoids in Tongkat Ali dietary supplements by liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Han, Young Min; Jang, Moonhee; Kim, In Sook; Kim, Seung Hyun; Yoo, Hye Hyun

    2015-07-01

    Tongkat Ali (Eurycoma longifolia) is one of the most popular traditional herbs in Southeast Asia and generally consumed as forms of dietary supplements, tea, or drink additives for coffee or energy beverages. In this study, the liquid chromatography with tandem mass spectrometry method for the simultaneous quantitation of six major quassinoids of Tongkat Ali (eurycomanone, 13,21-dihydroeurycomanone, 13α(21)-epoxyeurycomanone, 14,15β-dihydroxyklaineanone, eurycomalactone, and longilactone) was developed and validated. Using the developed method, the content of the six quassinoids was measured in Tongkat Ali containing dietary supplement tablets or capsules, and the resulting data were used to confirm the presence of Tongkat Ali in those products. Among the six quassinoids, eurycomanone was the most abundant quassinoid in all samples tested. The developed method would be useful for the quality assessment of Tongkat Ali containing dietary supplements. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Rapid determination of vitamin D₃ in milk-based infant formulas by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Kwak, Byung-Man; Jeong, In-Seek; Lee, Moon-Seok; Ahn, Jang-Hyuk; Park, Jong-Su

    2014-12-15

    A rapid and simple sample preparation method for vitamin D3 (cholecalciferol) was developed for emulsified dairy products such as milk-based infant formulas. A sample was mixed in a 50 mL centrifuge tube with the same amount of water and isopropyl alcohol to achieve chemical extraction. Ammonium sulfate was used to induce phase separation. No-heating saponification was performed in the sample tube by adding KOH, NaCl, and NH3. Vitamin D3 was then separated and quantified using liquid chromatography-tandem mass spectrometry. The results for added recovery tests were in the range 93.11-110.65%, with relative standard deviations between 2.66% and 2.93%. The results, compared to those obtained using a certified reference material (SRM 1849a), were within the range of the certificated values. This method could be implemented in many laboratories that require time and labour saving. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Identification of the Related Substances in Ampicillin Capsule by Rapid Resolution Liquid Chromatography Coupled with Electrospray Ionization Tandem Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Lei Zhang

    2014-01-01

    Full Text Available Rapid Resolution Liquid Chromatography coupled with Electrospray Ionization Tandem Mass Spectrometry (RRLC-ESI-MSn was used to separate and identify related substances in ampicillin capsule. The fragmentation behaviors of related substances were used to identify their chemical structures. Finally, a total of 13 related substances in ampicillin capsule were identified, including four identified components for the first time and three groups of isomers on the basis of the exact mass, fragmentation behaviors, retention time, and chemical structures in the literature. This study avoided time-consuming and complex chemosynthesis of related substances of ampicillin and the results could be useful for the quality control of ampicillin capsule to guarantee its safety in clinic. In the meantime, it provided a good example for the rapid identification of chemical structures of related substances of drugs.

  5. Quantification of pramipexole in human plasma by liquid chromatography tandem mass spectrometry using tamsulosin as internal standard.

    Science.gov (United States)

    Nirogi, Ramakrishna V S; Kandikere, Vishwottam; Shrivastava, Wishu; Mudigonda, Koteshwara; Maurya, Santosh; Ajjala, Devender

    2007-11-01

    A high-performance liquid chromatography/electrospray ionization tandem mass spectrometry method was developed and validated for the quantification of pramipexole in human plasma. Following liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a reverse-phase column and analyzed by MS/MS in the multiple reaction monitoring mode using the respective [M + H](+) ions, m/z 212/152 for pramipexole and m/z 409/228 for the IS. The method exhibited a linear dynamic range of 200-8000 pg/mL for pramipexole in human plasma. The lower limit of quantification was 200 pg/mL with a relative standard deviation of less than 8%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. A run time of 3.5 min for each sample made it possible to analyze more than 200 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies. Copyright (c) 2007 John Wiley & Sons, Ltd.

  6. Validation of a chiral liquid chromatography-tandem mass spectrometry method for the determination of pantoprazole in dog plasma.

    Science.gov (United States)

    Chen, Meixia; Xia, Yu; Ma, Zhiyu; Li, Liang; Zhong, Dafang; Chen, Xiaoyan

    2012-10-01

    Pantoprazole (PAN), a selective proton pump inhibitor, is used clinically as a racemic mixture for the treatment of acid-related gastrointestinal disorders. To investigate its stereoselective pharmacokinetics, a chiral liquid chromatography-tandem mass spectrometry method was developed and validated to determine the pantoprazole enantiomers in dog plasma. After liquid-liquid extraction, a baseline resolution of enantiomers was achieved on an ovomucoid column using the mobile phase of methanol:acetonitrile:10mM ammonium formate (pH 7) (10.4:2.6:87, v/v/v) at 30°C within 10min. Stable isotopically labeled (+)-d(3)-pantoprazole and (-)-d(3)-pantoprazole were used as internal standards. Acquisition of mass spectrometric data was performed in multiple reaction monitoring mode via positive atmospheric pressure chemical ionization. The method was linear in the concentration range of 20.0-10,000ng/mL for each enantiomer using 25μL of dog plasma. The lower limit of quantification (LLOQ) for each enantiomer was 20.0ng/mL. Intra- and inter-day precision ranged from 3.2% to 10.3% for (+)-pantoprazole and 3.7-10.0% for (-)-pantoprazole. Accuracy varied from -1.4% to -0.2% for (+)-pantoprazole and -1.6% to 0.8% for (-)-pantoprazole. The validated method was applied successfully for stereoselective pharmacokinetic studies of racemic pantoprazole. Copyright © 2012 Elsevier B.V. All rights reserved.

  7. Extraction and Liquid Chromatography-Tandem Mass Spectrometry Detection of 3-Monochloropropanediol Esters and Glycidyl Esters in Infant Formula.

    Science.gov (United States)

    Leigh, Jessica K; MacMahon, Shaun

    2016-12-14

    A method was developed for the extraction of fatty acid esters of 3-chloro-1,2-propanediol (3-MCPD) and glycidol from infant formula, followed by quantitative analysis of the extracts using liquid chromatography-tandem mass spectrometry (LC-MS/MS). These process-induced chemical contaminants are found in refined vegetable oils, and studies have shown that they are potentially carcinogenic and/or genotoxic, making their presence in edible oils (and processed foods containing these oils) a potential health risk. The extraction procedure involves a liquid-liquid extraction, where powdered infant formula is dissolved in water and extracted with ethyl acetate. Following shaking, centrifugation, and drying of the organic phase, the resulting fat extract is cleaned-up using solid-phase extraction and analyzed by LC-MS/MS. Method performance was confirmed by verifying the percent recovery of each 3-MCPD and glycidyl ester in a homemade powdered infant formula reference material. Average ester recoveries in the reference material ranged from 84.9 to 109.0% (0.6-9.5% RSD). The method was also validated by fortifying three varieties of commercial infant formulas with a 3-MCPD and glycidyl ester solution. Average recoveries of the esters across all concentrations and varieties of infant formula ranged from 88.7 to 107.5% (1.0-9.5% RSD). Based on the validation results, this method is suitable for producing 3-MCPD and glycidyl ester occurrence data in all commercially available varieties of infant formula.

  8. Quantification of Fatty Acid Oxidation Products Using On-line High Performance Liquid Chromatography Tandem Mass Spectrometry

    Science.gov (United States)

    Levison, Bruce S.; Zhang, Renliang; Wang, Zeneng; Fu, Xiaoming; DiDonato, Joseph A.; Hazen, Stanley L.

    2013-01-01

    Oxidized fatty acids formed via lipid peroxidation are implicated in pathological processes such as inflammation and atherosclerosis. A number of methods may be used to detect specific oxidized fatty acids containing a single or multiple combinations of epoxide, hydroxyl, ketone and hydroperoxide moieties on varying carbon chain lengths from C8 up to C30. Some of these methods are nonspecific and their use in biological systems is fraught with difficulty. Measures of specific-oxidized fatty acid derivatives help in identifying oxidation pathways in pathological processes. We used liquid chromatography coupled with electrospray ionization tandem mass spectrometry (LC-MS/MS) as efficient, selective and sensitive methods for identifying and analyzing multiple specific fatty acid peroxidation products in human plasma and other biological matrices. We then distilled the essential components of a number of these analyses to provide an efficient protocol by which fatty acid oxidation products and their parent compounds can be determined. In this protocol, addition of synthetic internal standard to the sample, followed by base hydrolysis at elevated temperature, and liquid-liquid phase sample extraction with lighter than water solvents facilitates isolation of the oxidized fatty acid species. These species can be identified and accurately quantified using stable isotope dilution and multiple reaction monitoring. Use of a coupled multiplexed gradient HPLC system on the front end enables high-throughput chromatography and more efficient use of mass spectrometer time. PMID:23499838

  9. A high-throughput method for liquid chromatography-tandem mass spectrometry determination of plasma alkylresorcinols, biomarkers of whole grain wheat and rye intake

    DEFF Research Database (Denmark)

    Ross, Alastair B; Svelander, Cecilia; Savolainen, Otto I

    2016-01-01

    supported extraction methods for extracting alkylresorcinols from plasma and improved a normal-phase liquid chromatography coupled to a tandem mass spectrometer method to reduce sample analysis time. The method was validated and compared with gas chromatography-mass spectrometry analysis. Sample preparation...

  10. Specific determination of 20 primary aromatic amines in aqueous food simulants by liquid chromatography-electrospray ionization-tandem mass spectrometry

    DEFF Research Database (Denmark)

    Mortensen, Sarah Kelly; Trier, Xenia Thorsager; Foverskov, Annie

    2005-01-01

    A multi-analyte method without any pre-treatment steps using reversed-phase liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) was developed and applied for the determination of 20 primary aromatic amines (PAA) associated with polyurethane (PUR) products or azo...

  11. Simultaneous identification of multiple β-lactamases in Acinetobacter baumannii in relation to carbapenem and ceftazidime resistance, using liquid chromatography-tandem mass spectrometry

    NARCIS (Netherlands)

    Trip, H.; Mende, K.; Majchrzykiewicz-Koehorst, J.A.; Sedee, N.J.A.; Hulst, A.G.; Jansen, H.J.; Murray, C.K.; Paauw, A.

    2015-01-01

    Shotgun proteomics using liquid chromatography-tandem mass spectrometry (LC-MS/MS) was applied to detect β-lactamases in clinical Acinetobacter baumannii isolates. The correlation of the detection of β-lactamase proteins (rather than PCR detection of the corresponding genes) with the resistance

  12. A validated liquid chromatography-tandem mass spectrometry method for the quantitative determination of 4 beta-hydroxycholesterol in human plasma

    NARCIS (Netherlands)

    van de Merbel, Nico C.; Bronsema, Kees J.; van Hout, Mischa W. J.; Nilsson, Ralf; Sillen, Henrik

    2011-01-01

    A novel liquid chromatography-tandem mass spectrometry method is described for the quantitative determination of the endogenous CYP 3A4/5 marker 4 beta-hydroxycholesterol in human K(2)-EDTA plasma. It is based on alkaline hydrolysis to convert esterified to free 4 beta-hydroxycholesterol, followed

  13. Residue analysis of sixty pesticides in red swamp crayfish using QuEChERS with high-performance liquid chromatography-tandem mass spectrometry

    Science.gov (United States)

    In this study, a multi-residue analytical method using QuEChERS extraction and dispersive solid-phase extraction (d-SPE) cleanup followed by high-performance liquid chromatography–tandem mass spectrometry (HPLC-MS/MS) was developed for rapid determination of 60 pesticide residues in whole crayfish a...

  14. Liquid chromatography with tandem mass spectrometry quantification of urinary proanthocyanin A2 dimer and its potential use as a biomarker of cranberry intake

    Science.gov (United States)

    The lack of a biomarker for the consumption of cranberries has confounded the interpretation of several studies investigating the effect of cranberry products, especially juices, on health outcomes. The objectives of this pilot study were to develop a liquid chromatography tandem mass spectrometric ...

  15. Ultra-high-performance liquid chromatography-tandem mass spectrometry measurement of climbazole deposition from hair care products onto artificial skin and human scalp

    NARCIS (Netherlands)

    Chen, G.; Hoptroff, M.; Fei, X.; Su, Y.; Janssen, H.-G.

    2013-01-01

    A sensitive and specific ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed and validated for the measurement of climbazole deposition from hair care products onto artificial skin and human scalp. Deuterated climbazole was used as the internal

  16. Dispersive solid phase extraction combined with ion-pair ultra high-performance liquid chromatography tandem mass spectrometry for quantification of nucleotides in Lactococcus lactis

    DEFF Research Database (Denmark)

    Magdenoska, Olivera; Martinussen, Jan; Thykær, Jette

    2013-01-01

    solid phase extraction with charcoal and subsequent analysis with ion-pair liquid chromatography coupled with electrospray ionization tandem mass spectrometry was established for quantification of intracellular pools of the 28 most important nucleotides. The method can handle extracts where cells leak...

  17. Isocratic Solid Phase Extraction-Liquid Chromatography (SPE-LC) Interfaced to High-Performance Tandem Mass Spectrometry for Rapid Protein Identification

    DEFF Research Database (Denmark)

    Hørning, Ole B; Kjeldsen, Frank; Theodorsen, Søren

    2008-01-01

    the isocratic solid phase extraction-liquid chromatography (SPE-LC) technology for rapid separation ( approximately 8 min) of simple peptide samples. We now extend these studies to demonstrate the potential of SPE-LC separation in combination with a hybrid linear ion trap-Orbitrap tandem mass spectrometer...

  18. Determination of telmisartan in human blood plasma: Part II: Liquid chromatography-tandem mass spectrometry method development, comparison to immunoassay and pharmacokinetic study

    NARCIS (Netherlands)

    Hempen, C.M.; Gläsle-Schwarz, Liane; Kunz, Ulrich; Karst, U.

    2006-01-01

    A new liquid chromatography/atmospheric pressure chemical ionization-tandem mass spectrometry (LC/APCI-MS/MS) method with on-line sample clean-up for the determination of telmisartan in human blood plasma is presented. This technique is compared to a previously introduced enzyme-linked immunosorbent

  19. Liquid chromatography-tandem mass spectrometric assay for the T790M mutant EGFR inhibitor osimertinib (AZD9291) in human plasma

    NARCIS (Netherlands)

    Rood, Johannes J M; van Bussel, Mark T J; Schellens, Jan H M; Beijnen, Jos H; Sparidans, Rolf W

    2016-01-01

    A method for the quantitative analysis by ultra-performance liquid chromatography-tandem mass spectrometry of the highly selective irreversible covalent inhibitor of EGFR-TK, osimertinib in human plasma was developed and validated, using pazopanib as an internal standard. The validation was

  20. A new liquid chromatography - tandem mass spectrometry method using atmospheric pressure photo ionization for the simultaneous determination of azaarenes and azaarones in Dutch river sediments

    NARCIS (Netherlands)

    Brulik, J.; Simek, Z.; de Voogt, P.

    2013-01-01

    A new method for the analysis of azaarenes and their degradation products (azaarones) was developed, optimized and validated using liquid chromatography coupled with atmospheric pressure photo ionization tandem mass spectrometric detection (LC-APPI/MS/MS). Seventeen compounds including 4 PAHs

  1. METHOD 544. DETERMINATION OF MICROCYSTINS AND NODULARIN IN DRINKING WATER BY SOLID PHASE EXTRACTION AND LIQUID CHROMATOGRAPHY/TANDEM MASS SPECTROMETRY (LC/MS/MS)

    Science.gov (United States)

    Method 544 is an accurate and precise analytical method to determine six microcystins (including MC-LR) and nodularin in drinking water using solid phase extraction and liquid chromatography tandem mass spectrometry (SPE-LC/MS/MS). The advantage of this SPE-LC/MS/MS is its sensi...

  2. The use of ultra-high pressure liquid chromatography with tandem mass spectrometric detection of analysis of agrochemical residues and mycotoxines in food - challenges and applications

    Science.gov (United States)

    In the field of food contaminant analysis, the most significant development of recent years has been the integration of ultra-high pressure liquid chromatography (UHPLC), coupled to tandem quadrupole mass spectrometry (MS/MS), into analytical applications. In this review, we describe the emergence o...

  3. Identification and Quantification of the Major Constituents in Egyptian Carob Extract by Liquid Chromatography?Electrospray Ionization-Tandem Mass Spectrometry

    OpenAIRE

    Owis, Asmaa Ibrahim; El-Naggar, El-Motaz Bellah

    2016-01-01

    Background: Carob - Ceratonia siliqua L., commonly known as St John's-bread or locust bean, family Fabaceae - is one of the most useful native Mediterranean trees. There is no data about the chromatography methods performed by high performance liquid chromatography (HPLC) for determining polyphenols in Egyptian carob pods. Objective: To establish a sensitive and specific liquid chromatography?electrospray ionization (ESI)-tandem mass spectrometry (MSn) methodology for the identification of th...

  4. Loading of free radicals on the functional graphene combined with liquid chromatography-tandem mass spectrometry screening method for the detection of radical-scavenging natural antioxidants.

    Science.gov (United States)

    Wang, Guoying; Shi, Gaofeng; Chen, Xuefu; Chen, Fuwen; Yao, Ruixing; Wang, Zhenju

    2013-11-13

    A novel free radical reaction combined with liquid chromatography electrospray ionization tandem mass spectrometry (FRR-LC-PDA-ESI/APCI-MS/MS) screening method was developed for the detection and identification of radical-scavenging natural antioxidants. Functionalized graphene was prepared by chemical method for loading free radicals (superoxide radical, peroxyl radical and PAHs free radical). Separation was performed with and without a preliminary exposure of the sample to specific free radicals on the functionalized graphene, which can facilitate reaction kinetics (charge transfers) between free radicals and potential antioxidants. The difference in chromatographic peak areas is used to identify potential antioxidants. The structure of the antioxidants in one sample (Swertia chirayita) is identified using MS/MS and comparison with standards. Thirteen compounds were found to possess potential antioxidant activity, and their free radical-scavenging capacities were investigated. The thirteen compounds were identified as 1,3,5-trihydroxyxanthone-8-O-β-D-glucopyranoside (PD1), norswertianin (PD2), 1,3,5,8-tetrahydroxyxanthone (PD3), 3, 3', 4', 5, 8-penta hydroxyflavone-6-β-D-glucopyranosiduronic acid-6'-pentopyranose-7-O-glucopyranoside (PD4), 1,5,8-trihydroxy-3-methoxyxanthone (PD5), swertiamarin (PS1), 2-C-β-D-glucopyranosyl-1,3,7-trihydroxylxanthone (PS2), 1,3,7-trihydroxylxanthone-8-O-β-D-glucopyranoside (PL1), 1,3,8-trihydroxyl xanthone-5-O-β-D-glucopyranoside (PL2), 1,3,7-trihydroxy-8-methoxyxanthone (PL3), 1,2,3-trihydroxy-7,8-dimethoxyxanthone (PL4), 1,8-dihydroxy-2,6-dimethoxy xanthone (PL5) and 1,3,5,8-tetramethoxydecussatin (PL6). The reactivity and SC50 values of those compounds were investigated, respectively. PD4 showed the strongest capability for scavenging PAHs free radical; PL4 showed prominent scavenging capacities in the lipid peroxidation processes; it was found that all components in S. chirayita exhibited weak reactivity in the superoxide

  5. Analysis of intracellular and extracellular microcystin variants in sediments and pore waters by accelerated solvent extraction and high performance liquid chromatography-tandem mass spectrometry

    International Nuclear Information System (INIS)

    Zastepa, Arthur; Pick, Frances R.; Blais, Jules M.; Saleem, Ammar

    2015-01-01

    Highlights: • First analytical method for intracellular microcystins (MCs) in sediment. • Includes a suite of variants (LR, 7dm LR, RR, YR, WR, LA, LF, LY, LW) and nodularin. • Reports the first measurements of MCs in sediment pore waters. • MCs detected in >100 year old lake sediments suggesting long-term preservation. • Sediment-pore water distribution (K d ) differed between variants suggesting differences in environmental fate. - Abstract: The fate and persistence of microcystin cyanotoxins in aquatic ecosystems remains poorly understood in part due to the lack of analytical methods for microcystins in sediments. Existing methods have been limited to the extraction of a few extracellular microcystins of similar chemistry. We developed a single analytical method, consisting of accelerated solvent extraction, hydrophilic–lipophilic balance solid phase extraction, and reversed phase high performance liquid chromatography-tandem mass spectrometry, suitable for the extraction and quantitation of both intracellular and extracellular cyanotoxins in sediments as well as pore waters. Recoveries of nine microcystins, representing the chemical diversity of microcystins, and nodularin (a marine analogue) ranged between 75 and 98% with one, microcystin-RR (MC-RR), at 50%. Chromatographic separation of these analytes was achieved within 7.5 min and the method detection limits were between 1.1 and 2.5 ng g −1 dry weight (dw). The robustness of the method was demonstrated on sediment cores collected from seven Canadian lakes of diverse geography and trophic states. Individual microcystin variants reached a maximum concentration of 829 ng g −1 dw on sediment particles and 132 ng mL −1 in pore waters and could be detected in sediments as deep as 41 cm (>100 years in age). MC-LR, -RR, and -LA were more often detected while MC-YR, -LY, -LF, and -LW were less common. The analytical method enabled us to estimate sediment-pore water distribution coefficients (K d

  6. Analysis of intracellular and extracellular microcystin variants in sediments and pore waters by accelerated solvent extraction and high performance liquid chromatography-tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Zastepa, Arthur, E-mail: arthur.zastepa@gmail.com; Pick, Frances R.; Blais, Jules M.; Saleem, Ammar

    2015-05-04

    Highlights: • First analytical method for intracellular microcystins (MCs) in sediment. • Includes a suite of variants (LR, {sup 7dm}LR, RR, YR, WR, LA, LF, LY, LW) and nodularin. • Reports the first measurements of MCs in sediment pore waters. • MCs detected in >100 year old lake sediments suggesting long-term preservation. • Sediment-pore water distribution (K{sub d}) differed between variants suggesting differences in environmental fate. - Abstract: The fate and persistence of microcystin cyanotoxins in aquatic ecosystems remains poorly understood in part due to the lack of analytical methods for microcystins in sediments. Existing methods have been limited to the extraction of a few extracellular microcystins of similar chemistry. We developed a single analytical method, consisting of accelerated solvent extraction, hydrophilic–lipophilic balance solid phase extraction, and reversed phase high performance liquid chromatography-tandem mass spectrometry, suitable for the extraction and quantitation of both intracellular and extracellular cyanotoxins in sediments as well as pore waters. Recoveries of nine microcystins, representing the chemical diversity of microcystins, and nodularin (a marine analogue) ranged between 75 and 98% with one, microcystin-RR (MC-RR), at 50%. Chromatographic separation of these analytes was achieved within 7.5 min and the method detection limits were between 1.1 and 2.5 ng g{sup −1} dry weight (dw). The robustness of the method was demonstrated on sediment cores collected from seven Canadian lakes of diverse geography and trophic states. Individual microcystin variants reached a maximum concentration of 829 ng g{sup −1} dw on sediment particles and 132 ng mL{sup −1} in pore waters and could be detected in sediments as deep as 41 cm (>100 years in age). MC-LR, -RR, and -LA were more often detected while MC-YR, -LY, -LF, and -LW were less common. The analytical method enabled us to estimate sediment-pore water

  7. Development and validation of a liquid chromatography tandem mass spectrometry method for the determination of cannabinoids and phase I and II metabolites in meconium.

    Science.gov (United States)

    Prego-Meleiro, Pablo; Lendoiro, Elena; Concheiro, Marta; Cruz, Angelines; López-Rivadulla, Manuel; de Castro, Ana

    2017-05-12

    A liquid chromatography-tandem mass spectrometry (LC-MSMS) method was developed and fully validated for the determination of Δ 9 -tetrahydrocannabinol (THC), 11-hydroxyTHC (OHTHC), 11-nor-9-carboxyTHC (THCCOOH), 8-β-11-dihydroxyTHC (diOHTHC), cannabinol, cannabidiol, and THC and THCCOOH glucuronides in 0.25±0.02g meconium. Samples were homogenized in methanol and subjected to cation exchange solid-phase extraction. Chromatographic separation was performed on a Kinetex C18 column (50 mm×2.1mm, 2.6μm) at 35°C, with a gradient of 0.1% formic acid in water and acetonitrile at a flow rate of 0.3 mL/min; total run time was 10min. Two transitions per analyte were monitored in MRM mode. The method was specific and sensitive; LOD was from 1 to 2ng/g, and LOQ from 4 to 10ng/g; linearity ranged from 4 to 400 ng/g for all the analytes, except for THC glucuronide (10-400ng/g); intra-assay, inter-assay and total imprecision were <11.2%, <13.45% and <15.6%, respectively; accuracy ranged from 93.9% to 109.0% of the target concentration; matrix effect, extraction and process efficiency ranged from -26.4% to -71.4%, 49.9% to 69.5% and 14.3% to 45.0%, respectively. The inclusion of THC and THCCOOH glucuronides avoided the need for the hydrolysis process, thus facilitating sample pretreatment. Application of the method to 19 authentic meconium specimens from uncontrolled pregnancies or women suspicious of drug consumption revealed fetal cannabis exposure in 4 newborns. THCCOOH (24.1-288.8ng/g), diOHTHC (53.2-332.4ng/g), THC (4.2-7.7ng/g), CBN (30.7-93.3ng/g) and CBD (7.1-251.5ng/g) were detected in all cases; THCCOOH glucuronide (190.2-306.8ng/g) in 3 cases; and OHTHC (11.9ng/g) in the remaining one; however, THC glucuronide was not identified in any specimen. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Simultaneous analysis of nine aromatic amines in mainstream cigarette smoke using online solid-phase extraction combined with liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Zhang, Jie; Bai, Ruoshi; Zhou, Zhaojuan; Liu, Xingyu; Zhou, Jun

    2017-04-01

    A fully automated analytical method was developed and validated by this present study. The method was based on two-dimensional (2D) online solid-phase extraction liquid chromatography-tandem mass spectrometry (SPE-LC-MS/MS) to determine nine aromatic amines (AAs) in mainstream smoke (MSS) simultaneously. As a part of validation process, AAs yields for 16 top-selling commercial cigarettes from China market were evaluated by the developed method under both Health Canada Intensive (HCI) and ISO machine smoking regimes. The gas phase of MSS was trapped by 25 mL 0.6 M hydrochloric acid solution, while the particulate phase was collected on a glass fiber filter. Then, the glass fiber pad was extracted with hydrochloric acid solution in an ultrasonic bath. The extract was analyzed with 2D online SPE-LC-MS/MS. In order to minimize the matrix effects of sample on each analyte, two cartridges with different extraction mechanisms were utilized to cleanup disturbances of different polarity, which were performed by the 2D SPE. A phenyl-hexyl analytical column was used to achieve a chromatographic separation. Under the optimized conditions, the isomers of p-toluidine, m-toluidine and o-toluidine, 3-aminobiphenyl and 4-aminobiphenyl, and 1-naphthylamine and 2-naphthylamine were baseline separated with good peak shapes for the first time. The limits of detection for nine AAs ranged from 0.03 to 0.24 ng cig -1 . The recovery of the measurement of nine AAs was from 84.82 to 118.47%. The intra-day and inter-day precisions of nine AAs were less than 10 and 16%, respectively. Compared with ISO machine smoking regime, the AAs yields in MSS were 1.17 to 3.41 times higher under HCI machine smoking regime. Graphical abstract New method using online SPE-LC/MS/MS for analysis of aromatic amines in mainstream cigarette smoke.

  9. Analysis of intracellular and extracellular microcystin variants in sediments and pore waters by accelerated solvent extraction and high performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Zastepa, Arthur; Pick, Frances R; Blais, Jules M; Saleem, Ammar

    2015-05-04

    The fate and persistence of microcystin cyanotoxins in aquatic ecosystems remains poorly understood in part due to the lack of analytical methods for microcystins in sediments. Existing methods have been limited to the extraction of a few extracellular microcystins of similar chemistry. We developed a single analytical method, consisting of accelerated solvent extraction, hydrophilic-lipophilic balance solid phase extraction, and reversed phase high performance liquid chromatography-tandem mass spectrometry, suitable for the extraction and quantitation of both intracellular and extracellular cyanotoxins in sediments as well as pore waters. Recoveries of nine microcystins, representing the chemical diversity of microcystins, and nodularin (a marine analogue) ranged between 75 and 98% with one, microcystin-RR (MC-RR), at 50%. Chromatographic separation of these analytes was achieved within 7.5 min and the method detection limits were between 1.1 and 2.5 ng g(-1) dry weight (dw). The robustness of the method was demonstrated on sediment cores collected from seven Canadian lakes of diverse geography and trophic states. Individual microcystin variants reached a maximum concentration of 829 ng g(-1) dw on sediment particles and 132 ng mL(-1) in pore waters and could be detected in sediments as deep as 41 cm (>100 years in age). MC-LR, -RR, and -LA were more often detected while MC-YR, -LY, -LF, and -LW were less common. The analytical method enabled us to estimate sediment-pore water distribution coefficients (K(d)), MC-RR had the highest affinity for sediment particles (log K(d)=1.3) while MC-LA had the lowest affinity (log K(d)=-0.4), partitioning mainly into pore waters. Our findings confirm that sediments serve as a reservoir for microcystins but suggest that some variants may diffuse into overlying water thereby constituting a new route of exposure following the dissipation of toxic blooms. The method is well suited to determine the fate and persistence of different

  10. Determination of human-use pharmaceuticals in filtered water by direct aqueous injection: high-performance liquid chromatography/tandem mass spectrometry

    Science.gov (United States)

    Furlong, Edward T.; Noriega, Mary C.; Kanagy, Christopher J.; Kanagy, Leslie K.; Coffey, Laura J.; Burkhardt, Mark R.

    2014-01-01

    This report describes a method for the determination of 110 human-use pharmaceuticals using a 100-microliter aliquot of a filtered water sample directly injected into a high-performance liquid chromatograph coupled to a triple-quadrupole tandem mass spectrometer using an electrospray ionization source operated in the positive ion mode. The pharmaceuticals were separated by using a reversed-phase gradient of formic acid/ammonium formate-modified water and methanol. Multiple reaction monitoring of two fragmentations of the protonated molecular ion of each pharmaceutical to two unique product ions was used to identify each pharmaceutical qualitatively. The primary multiple reaction monitoring precursor-product ion transition was quantified for each pharmaceutical relative to the primary multiple reaction monitoring precursor-product transition of one of 19 isotope-dilution standard pharmaceuticals or the pesticide atrazine, using an exact stable isotope analogue where possible. Each isotope-dilution standard was selected, when possible, for its chemical similarity to the unlabeled pharmaceutical of interest, and added to the sample after filtration but prior to analysis. Method performance for each pharmaceutical was determined for reagent water, groundwater, treated drinking water, surface water, treated wastewater effluent, and wastewater influent sample matrixes that this method will likely be applied to. Each matrix was evaluated in order of increasing complexity to demonstrate (1) the sensitivity of the method in different water matrixes and (2) the effect of sample matrix, particularly matrix enhancement or suppression of the precursor ion signal, on the quantitative determination of pharmaceutical concentrations. Recovery of water samples spiked (fortified) with the suite of pharmaceuticals determined by this method typically was greater than 90 percent in reagent water, groundwater, drinking water, and surface water. Correction for ambient environmental

  11. Quantitative analysis of phytosterols in edible oils using APCI liquid chromatography-tandem mass spectrometry

    Science.gov (United States)

    Mo, Shunyan; Dong, Linlin; Hurst, W. Jeffrey; van Breemen, Richard B.

    2014-01-01

    Previous methods for the quantitative analysis of phytosterols have usually used GC-MS and require elaborate sample preparation including chemical derivatization. Other common methods such as HPLC with absorbance detection do not provide information regarding the identity of the analytes. To address the need for an assay that utilizes mass selectivity while avoiding derivatization, a quantitative method based on LC-tandem mass spectrometry (LC-MS-MS) was developed and validated for the measurement of six abundant dietary phytosterols and structurally related triterpene alcohols including brassicasterol, campesterol, cycloartenol, β-sitosterol, stigmasterol, and lupeol in edible oils. Samples were saponified, extracted with hexane and then analyzed using reversed phase HPLC with positive ion atmospheric pressure chemical ionization tandem mass spectrometry and selected reaction monitoring. The utility of the LC-MS-MS method was demonstrated by analyzing 14 edible oils. All six compounds were present in at least some of the edible oils. The most abundant phytosterol in all samples was β-sitosterol, which was highest in corn oil at 4.35 ± 0.03 mg/g, followed by campesterol in canola oil at 1.84 ± 0.01 mg/g. The new LC-MS-MS method for the quantitative analysis of phytosterols provides a combination of speed, selectivity and sensitivity that exceed those of previous assays. PMID:23884629

  12. Determination of Diffusion Coefficients and Activation Energy of Selected Organic Liquids using Reversed-Flow Gas Chromatographic Technique

    International Nuclear Information System (INIS)

    Khalisanni Khalid; Rashid Atta Khan; Sharifuddin Mohd Zain

    2012-01-01

    Evaporation of vaporize organic liquid has ecological consequences when the compounds are introduced into both freshwater and marine environments through industrial effluents, or introduced directly into the air from industrial unit processes such as bioreactors and cooling towers. In such cases, a rapid and simple method are needed to measure physicochemical properties of the organic liquids. The Reversed-Flow Gas Chromatography (RF-GC) sampling technique is an easy, fast and accurate procedure. It was used to measure the diffusion coefficients of vapors from liquid into a carrier gas and at the same time to determine the rate coefficients for the evaporation of the respective liquid. The mathematical expression describing the elution curves of the samples peaks was derived and used to calculate the respective parameters for the selected liquid pollutants selected such as methanol, ethanol, 1-propanol, 1-butanol, n-pentane, n-hexane, n-heptane and n-hexadecane, evaporating into the carrier gas of nitrogen. The values of diffusion coefficients found were compared with those calculated theoretically or reported in the literature. The values of evaporation rate were used to determine the activation energy of respective samples using Arrhenius equation. An interesting finding of this work is by using an alternative mathematical analysis based on equilibrium at the liquid-gas interphase, the comparison leads to profound agreement between theoretical values of diffusion coefficients and experimental evidence. (author)

  13. Simple setup for gas-phase H/D exchange mass spectrometry coupled to electron transfer dissociation and ion mobility for analysis of polypeptide structure on a liquid chromatographic time scale.

    Science.gov (United States)

    Mistarz, Ulrik H; Brown, Jeffery M; Haselmann, Kim F; Rand, Kasper D

    2014-12-02

    Gas-phase hydrogen/deuterium exchange (HDX) is a fast and sensitive, yet unharnessed analytical approach for providing information on the structural properties of biomolecules, in a complementary manner to mass analysis. Here, we describe a simple setup for ND3-mediated millisecond gas-phase HDX inside a mass spectrometer immediately after ESI (gas-phase HDX-MS) and show utility for studying the primary and higher-order structure of peptides and proteins. HDX was achieved by passing N2-gas through a container filled with aqueous deuterated ammonia reagent (ND3/D2O) and admitting the saturated gas immediately upstream or downstream of the primary skimmer cone. The approach was implemented on three commercially available mass spectrometers and required no or minor fully reversible reconfiguration of gas-inlets of the ion source. Results from gas-phase HDX-MS of peptides using the aqueous ND3/D2O as HDX reagent indicate that labeling is facilitated exclusively through gaseous ND3, yielding similar results to the infusion of purified ND3-gas, while circumventing the complications associated with the use of hazardous purified gases. Comparison of the solution-phase- and gas-phase deuterium uptake of Leu-Enkephalin and Glu-Fibrinopeptide B, confirmed that this gas-phase HDX-MS approach allows for labeling of sites (heteroatom-bound non-amide hydrogens located on side-chains, N-terminus and C-terminus) not accessed by classical solution-phase HDX-MS. The simple setup is compatible with liquid chromatography and a chip-based automated nanoESI interface, allowing for online gas-phase HDX-MS analysis of peptides and proteins separated on a liquid chromatographic time scale at increased throughput. Furthermore, online gas-phase HDX-MS could be performed in tandem with ion mobility separation or electron transfer dissociation, thus enabling multiple orthogonal analyses of the structural properties of peptides and proteins in a single automated LC-MS workflow.

  14. Assessment of strobilurin fungicides' content in soya-based drinks by liquid micro-extraction and liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Campillo, Natalia; Iniesta, María Jesús; Viñas, Pilar; Hernández-Córdoba, Manuel

    2015-01-01

    Seven strobilurin fungicides were pre-concentrated from soya-based drinks using dispersive liquid-liquid micro-extraction (DLLME) with a prior protein precipitation step in acid medium. The enriched phase was analysed by liquid chromatography (LC) with dual detection, using diode array detection (DAD) and electrospray-ion trap tandem mass spectrometry (ESI-IT-MS/MS). After selecting 1-undecanol and methanol as the extractant and disperser solvents, respectively, for DLLME, the Taguchi experimental method, an orthogonal array design, was applied to select the optimal solvent volumes and salt concentration in the aqueous phase. The matrix effect was evaluated and quantification was carried out using external aqueous calibration for DAD and matrix-matched calibration method for MS/MS. Detection limits in the 4-130 and 0.8-4.5 ng g(-1) ranges were obtained for DAD and MS/MS, respectively. The DLLME-LC-DAD-MS method was applied to the analysis of 10 different samples, none of which was found to contain residues of the studied fungicides.

  15. Arsenic speciation by liquid chromatography coupled with ionspray tandem mass spectrometry

    DEFF Research Database (Denmark)

    Corr, J. J.; Larsen, Erik Huusfeldt

    1996-01-01

    Ionspray mass spectrometry, a well established organic analysis technique, has been coupled to high-performance liquid chromatography for speciation of organic arsenic compounds, The ionspray source and differentially pumped interface of the mass spectrometer were operated in dual modes...... fragmentation patterns showing molecular dissociation through an expected common product ion were obtained for the four arsenosugars, Molecular mode detection was utilized for qualitative verification of speciation analysis by high-performance liquid chromatography coupled to inductively coupled plasma mass...

  16. Multi-component analysis of tetracyclines, sulfonamides and tylosin in swine manure by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Jacobsen, Anne Marie; Halling-Sørensen, Bent

    2006-03-01

    A multi-component method focussing on thorough sample preparation has been developed for simultaneous analysis of swine manure for three classes of antibiotic-tetracyclines, sulfonamides, and tylosin. Liquid manure was initially freeze-dried and homogenised by pulverization before extraction by pressurised liquid extraction. The extraction was performed at 75 degrees C and 2,500 psig in three steps using two cycles with 0.2 mol L(-1) citric acid buffer (pH 4.7) and one cycle with a mixture of 80% methanol with 0.2 mol L(-1) citric acid (pH 3). After liquid-liquid extraction with heptane to remove lipids, the pH of the manure was adjusted to 3 with formic acid and the sample was vacuum-filtered through 0.6 mum glass-fibre filters. Finally the samples were pre-concentrated by tandem SPE (SAX-HLB). Recoveries were determined for manure samples spiked at three concentrations (50-5,000 microg kg(-1) dry matter); quantification was achieved by matrix-matched calibration. Recoveries were >70% except for oxytetracycline (42-54%), sulfadiazine (59-73%), and tylosin (9-35%) and did not vary with concentration or from day-to-day. Limits of quantification (LOQ) for all compounds, determined as a signal-to-noise ratio of 10, were in the range 10-100 microg kg(-1) dry matter. The suitability of the method was assessed by analysis of swine manure samples from six different pig-production sites, e.g. finishing pigs, sows, or mixed production. Residues of antibiotics were detected in all samples. The largest amounts were found for tetracyclines (up to 30 mg kg(-1) dry matter for the sum of CTC and ECTC). Sulfonamides were detected at concentrations up to 2 mg kg(-1) dry matter (SDZ); tylosin was not detected in any samples.

  17. Determination of fluoroquinolones in fish tissues, biological fluids, and environmental waters by liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Ziarrusta, Haizea; Val, Nahia; Dominguez, Haizea; Mijangos, Leire; Prieto, Ailette; Usobiaga, Aresatz; Etxebarria, Nestor; Zuloaga, Olatz; Olivares, Maitane

    2017-11-01

    This work describes the optimization, validation, and application in real samples of accurate and precise analytical methods to determine ten fluoroquinolones (FQs) (norfloxacin, enoxacin, pefloxacin, ofloxacin, levofloxacin, ciprofloxacin, danofloxacin, lomefloxacin, enrofloxacin, and sparfloxacin) in different environmental matrices, such as water (estuarine, seawater, and wastewater treatment plant effluent), fish tissues (muscle and liver), and fish biofluids (plasma and bile). The analysis step performed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) was fully optimized to improve the separation and detection steps. The extraction of analytes from fish tissues was accomplished using focused ultrasound solid-liquid extraction using methanol/acetic acid (95:5 v/v) as extractant. The preconcentration and clean-up steps were optimized in terms of extraction efficiency and cleanliness and the best strategy for each matrix was selected: (i) Oasis HLB for seawater and muscle, (ii) liquid-liquid extraction combined with Oasis HLB for the lipid-rich liver, (iii) the combination of Evolute-WAX and Oasis HLB for estuarine water and wastewater treatment plant effluent, and (iv) molecular imprinted polymers for biofluids. The methods afforded satisfactory apparent recoveries (80-126%) and repeatability (RSD < 15%), except for sparfloxacin, which showed a lack of correction with the available isotopically labeled surrogates ([ 2 H 8 ]-ciprofloxacin and [ 2 H 5 ]-enrofloxacin). Ciprofloxacin, norfloxacin, and ofloxacin were detected in both water and fish liver samples from the Biscay Coast at concentrations up to 278 ng/L and 4 ng/g, respectively. To the best of our knowledge, this work is one of the few analyzing up to ten FQs and in so many fish tissues and biofluids. Graphical abstract Determination of fluoroquinolones in different environmental matrices, such as water (estuarine, seawater, and wastewater treatment plant effluent), fish tissues (muscle

  18. Improving quantitative precision and throughput by reducing calibrator use in liquid chromatography-tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Rule, Geoffrey S., E-mail: geoffrey.s.rule@aruplab.com [ARUP Institute for Clinical and Experimental Pathology, 500 Chipeta Way, Salt Lake City, UT 84108 (United States); Rockwood, Alan L. [ARUP Institute for Clinical and Experimental Pathology, 500 Chipeta Way, Salt Lake City, UT 84108 (United States); Department of Pathology, University of Utah School of Medicine, 2100 Jones Medical Research Bldg., Salt Lake City, UT 84132 (United States)

    2016-05-05

    To improve efficiency in our mass spectrometry laboratories we have made efforts to reduce the number of calibration standards utilized for quantitation over time. We often analyze three or more batches of 96 samples per day, on a single instrument, for a number of assays. With a conventional calibration scheme at six concentration levels this amounts to more than 5000 calibration points per year. Modern LC-tandem mass spectrometric instrumentation is extremely rugged however, and isotopically labelled internal standards are widely available. This made us consider whether alternative calibration strategies could be utilized to reduce the number of calibration standards analyzed while still retaining high precision and accurate quantitation. Here we demonstrate how, by utilizing a single calibration point in each sample batch, and using the resulting response factor (RF) to update an existing, historical response factor (HRF), we are able to obtain improved precision over a conventional multipoint calibration approach, as judged by quality control samples. The laboratory component of this study was conducted with an existing LC tandem mass spectrometric method for three androgen analytes in our production laboratory. Using examples from both simulated and laboratory data we illustrate several aspects of our single point alternative calibration strategy and compare it with a conventional, multipoint calibration approach. We conclude that both the cost and burden of preparing multiple calibration standards with every batch of samples can be reduced while at the same time maintaining, or even improving, analytical quality. - Highlights: • Use of a weighted single point calibration approach improves quantitative precision. • A weighted response factor approach incorporates historical calibration information. • Several scenarios are discussed with regard to their influence on quantitation.

  19. Improving quantitative precision and throughput by reducing calibrator use in liquid chromatography-tandem mass spectrometry

    International Nuclear Information System (INIS)

    Rule, Geoffrey S.; Rockwood, Alan L.

    2016-01-01

    To improve efficiency in our mass spectrometry laboratories we have made efforts to reduce the number of calibration standards utilized for quantitation over time. We often analyze three or more batches of 96 samples per day, on a single instrument, for a number of assays. With a conventional calibration scheme at six concentration levels this amounts to more than 5000 calibration points per year. Modern LC-tandem mass spectrometric instrumentation is extremely rugged however, and isotopically labelled internal standards are widely available. This made us consider whether alternative calibration strategies could be utilized to reduce the number of calibration standards analyzed while still retaining high precision and accurate quantitation. Here we demonstrate how, by utilizing a single calibration point in each sample batch, and using the resulting response factor (RF) to update an existing, historical response factor (HRF), we are able to obtain improved precision over a conventional multipoint calibration approach, as judged by quality control samples. The laboratory component of this study was conducted with an existing LC tandem mass spectrometric method for three androgen analytes in our production laboratory. Using examples from both simulated and laboratory data we illustrate several aspects of our single point alternative calibration strategy and compare it with a conventional, multipoint calibration approach. We conclude that both the cost and burden of preparing multiple calibration standards with every batch of samples can be reduced while at the same time maintaining, or even improving, analytical quality. - Highlights: • Use of a weighted single point calibration approach improves quantitative precision. • A weighted response factor approach incorporates historical calibration information. • Several scenarios are discussed with regard to their influence on quantitation.

  20. Evaluation and application of a mixed-mode chromatographic stationary phase in two-dimensional liquid chromatography for the separation of traditional Chinese medicine.

    Science.gov (United States)

    Wei, Zhishen; Fu, Qing; Cai, Jianfeng; Huan, Liyun; Zhao, Jianchao; Shi, Hui; Jin, Yu; Liang, Xinmiao

    2016-06-01

    In this study, two mixed-mode chromatography stationary phases (C8SAX and C8SCX) were evaluated and used to establish a two-dimensional liquid chromatography system for the separation of traditional Chinese medicine. The chromatographic properties of the mixed-mode columns were systematically evaluated by comparing with other three columns of C8, strong anion exchanger, and strong cation exchanger. The result showed that C8SAX and C8SCX had a mixed-mode retention mechanism including electrostatic interaction and hydrophobic interaction. Especially, they were suitable for separating acidic and/or basic compounds and their separation selectivities could be easily adjusted by changing pH value. Then, several off-line 2D-LC systems based on the C8SAX in the first dimension and C8SAX, C8SCX, or C8 columns in the second dimension were developed to analyze a traditional Chinese medicine-Uncaria rhynchophylla. The two-dimensional liquid chromatography system of C8SAX (pH 3.0) × C8SAX (pH 6.0) exhibited the most effective peak distribution. Finally, fractions of U. rhynchophylla prepared from the first dimension were successfully separated on the C8SAX column with a gradient pH. Thus, the mixed-mode stationary phase could provide a platform to separate the traditional Chinese medicine in practical applications. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Determination of marker pteridins and biopterin reduced forms, tetrahydrobiopterin and dihydrobiopterin, in human urine, using a post-column photoinduced fluorescence liquid chromatographic derivatization method

    International Nuclear Information System (INIS)

    Canada-Canada, Florentina; Espinosa-Mansilla, Anunciacion; Munoz de la Pena, Arsenio; Mancha de Llanos, Alicia

    2009-01-01

    A liquid chromatographic method for the simultaneous analysis of marker pteridins and biopterin reduced forms, in urine samples is proposed. A Zorbax Eclipse XDB-C18 column was used for the chromatographic separation, using a 98/2 (v/v), citrate buffer (pH 5.5)-acetonitrile mobile phase, in isocratic mode. A post-column photoderivatization was carried out with an on-line photoreactor, located between a diode array detector (DAD) and a fast scanning fluorescence detector (FSFD). Neopterin (NEO), biopterin (BIO), pterin (PT) and dihydrobiopterin (BH2) were determined by measuring native fluorescence, using the photoreactor in OFF-mode, and tetrahydrobiopterin (BH4) was determined by measuring of the induced fluorescence of the generated photoproducts, using the photoreactor in ON-mode. In addition, Creatinine (CREA), as a reference of metabolites excrection in urine, was simultaneously determined using the DAD detector. Detection limits were 0.2, 13.0, 0.3, 0.3 and 3.5 ng mL -1 , for NEO, BH2, BIO, PT and BH4, respectively, and 0.4 μg mL -1 for CREA. Ratio values for NEO/CREA, PT/CREA, BH4/CREA, BH2/CREA, NEO/BIO and BIO total /CREA, in urine samples, of healthy children and adults, phenylketonuric children and infected mononucleosis children, are reported. A comparative study, about the mean values obtained for each of the compounds, by the present procedure and by the classical iodine oxidation method (Fukushimas method), has been performed, in urine samples belonging to healthy volunteers. The values obtained were BH4/CREA: 0.41, BH2/CREA: 0.31 and BIO total /CREA: 0.73, by the proposed method, and BH4/CREA: 0.35, BH2/CREA: 0.20 and BIO total /CREA: 0.48, by iodine oxidation method.

  2. Determination of marker pteridins and biopterin reduced forms, tetrahydrobiopterin and dihydrobiopterin, in human urine, using a post-column photoinduced fluorescence liquid chromatographic derivatization method

    Energy Technology Data Exchange (ETDEWEB)

    Canada-Canada, Florentina, E-mail: floricanada@gmail.com [Department of Analytical Chemistry, University of Extremadura, 06071 Badajoz (Spain); Espinosa-Mansilla, Anunciacion; Munoz de la Pena, Arsenio; Mancha de Llanos, Alicia [Department of Analytical Chemistry, University of Extremadura, 06071 Badajoz (Spain)

    2009-08-19

    A liquid chromatographic method for the simultaneous analysis of marker pteridins and biopterin reduced forms, in urine samples is proposed. A Zorbax Eclipse XDB-C18 column was used for the chromatographic separation, using a 98/2 (v/v), citrate buffer (pH 5.5)-acetonitrile mobile phase, in isocratic mode. A post-column photoderivatization was carried out with an on-line photoreactor, located between a diode array detector (DAD) and a fast scanning fluorescence detector (FSFD). Neopterin (NEO), biopterin (BIO), pterin (PT) and dihydrobiopterin (BH2) were determined by measuring native fluorescence, using the photoreactor in OFF-mode, and tetrahydrobiopterin (BH4) was determined by measuring of the induced fluorescence of the generated photoproducts, using the photoreactor in ON-mode. In addition, Creatinine (CREA), as a reference of metabolites excrection in urine, was simultaneously determined using the DAD detector. Detection limits were 0.2, 13.0, 0.3, 0.3 and 3.5 ng mL{sup -1}, for NEO, BH2, BIO, PT and BH4, respectively, and 0.4 {mu}g mL{sup -1} for CREA. Ratio values for NEO/CREA, PT/CREA, BH4/CREA, BH2/CREA, NEO/BIO and BIO{sub total}/CREA, in urine samples, of healthy children and adults, phenylketonuric children and infected mononucleosis children, are reported. A comparative study, about the mean values obtained for each of the compounds, by the present procedure and by the classical iodine oxidation method (Fukushimas method), has been performed, in urine samples belonging to healthy volunteers. The values obtained were BH4/CREA: 0.41, BH2/CREA: 0.31 and BIO{sub total}/CREA: 0.73, by the proposed method, and BH4/CREA: 0.35, BH2/CREA: 0.20 and BIO{sub total}/CREA: 0.48, by iodine oxidation method.

  3. Ultra-Performance Liquid Chromatography Tandem Mass Spectrometry Measurement of Caffeine in Caffeine-Laced Pants and in Urine and Skin of a Pants User

    OpenAIRE

    Pellegrini, Manuela; Orsi, Daniela De; Guarino, Carmine; Rotolo, Maria; Giovannandrea, Rita di; Pacifici, Roberta; Pichini, Simona

    2014-01-01

    A fast and sensitive ultra-performance liquid chromatography tandem mass spectrometry method was developed for the measurement of caffeine in caffeine-laced pants and in urine and skin of a pants user. The substance and its internal standard (N-ethylnorcotinine) were separated by reversed phase chromatography with 5 mM ammonium formate pH 3.0 and 0.3% formic acid in acetonitrile mobile phase (83:17 v/v) by isocratic elution and detected by tandem mass spectrometry operated in multiple reacti...

  4. A novel method for analysing key corticosteroids in polar bear (Ursus maritimus) hair using liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Weisser, Johan J; Hansen, Martin; Björklund, Erland; Sonne, Christian; Dietz, Rune; Styrishave, Bjarne

    2016-04-01

    This paper presents the development and evaluation of a methodology for extraction, clean-up and analysis of three key corticosteroids (aldosterone, cortisol and corticosterone) in polar bear hair. Such a methodology can be used to monitor stress biomarkers in polar bears and may provide as a useful tool for long-term and retrospective information. We developed a combined pressurized liquid extraction (PLE)-solid phase extraction (SPE) procedure for corticosteroid extraction and clean-up followed by high pressure liquid chromatography tandem mass spectrometry (HPLC-MS/MS) analysis. This procedure allows for the simultaneous determination of multiple steroids, which is in contrast to previous polar bear studies based on ELISA techniques. Absolute method recoveries were 81%, 75% and 60% for cortisol, corticosterone and aldosterone, respectively. We applied the developed method on a hair sample pooled from four East Greenland polar bears. Herein cortisol and corticosterone were successfully determined in levels of 0.32±0.02ng/g hair and 0.13±0.02ng/g hair, respectively. Aldosterone was below limit of detection (LODpolar bears was consistent with cortisol levels previously determined in the Southern Hudson Bay and James Bay in Canada using ELISA kits. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Multiclass determination of phytochemicals in vegetables and fruits by ultra high performance liquid chromatography coupled to tandem mass spectrometry.

    Science.gov (United States)

    Alarcón-Flores, María Isabel; Romero-González, Roberto; Vidal, José Luis Martínez; Frenich, Antonia Garrido

    2013-11-15

    In this study a simultaneous determination of several classes of phytochemicals (isoflavones, glucosinolates, flavones, flavonols and phenolic acids) in tomato, broccoli, carrot, eggplant and grape has been carried out by ultra high performance liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS). Solid-liquid extraction assisted by rotary agitator was utilised, using a mixture of methanol:water (80:20, v/v) as solvent. The analytical procedure was validated in all the matrices, obtaining recoveries ranging from 60% to 120% with repeatability values (expressed as relative standard deviations, RSDs) lower than 25%. Limits of quantification (LOQs) were always equal or lower than 50μg/kg, except for some glucosinolates (125μg/kg). Finally the method was applied to different matrices such as tomato, broccoli, carrot, grape and eggplant, observing that chlorogenic acid was detected in most of the samples at higher concentrations in relation to the other compounds. Copyright © 2013 Elsevier Ltd. All rights reserved.

  6. Development of Extraction Methods for the Analysis of Perfluorinated Compounds in Leather with High Performance Liquid Chromatography Tandem Mass Spectrometry

    Science.gov (United States)

    Zhang, Yan; Wang, Youchao; Tang, Chuanjiang; Nie, Jingmei; Xu, Chengtao

    2018-01-01

    Perfluorinated compounds (PFCs), used to provide water, oil, grease, heat and stain repellency to a range of textile and other products, have been found to be persistent in the environment and are associated with adverse effects on humans and wildlife. This study presents the development and validation of an analytical method to determine the simultaneous presence of eleven PFCs in leather using solid-phase extraction followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The perfluorinated compounds were primarily extracted from the samples by a liquid extraction procedure by ultrasonic, in which the parameters were optimized. Then the solid-phase extraction (SPE) is the most important advantages of the developed methodology. The sample volume and elution conditions were optimized by means of an experimental design. The proposed method was applied to determine the PFCs in leather, where the detection limits of the eleven compounds were 0.09-0.96 ng/L, and the recoveries of all compounds spiked at 5 ng/L concentration level were in the range of 65-96%, with a better RSD lower than 19% (n = 7).

  7. Liquid chromatography-tandem mass spectrometry analysis of perfluorooctane sulfonate and perfluorooctanoic Acid in fish fillet samples.

    Science.gov (United States)

    Paiano, Viviana; Fattore, Elena; Carrà, Andrea; Generoso, Caterina; Fanelli, Roberto; Bagnati, Renzo

    2012-01-01

    Perfluorooctane sulfonate (PFOS) and perfluorooctanoic (PFOA) acid are persistent contaminants which can be found in environmental and biological samples. A new and fast analytical method is described here for the analysis of these compounds in the edible part of fish samples. The method uses a simple liquid extraction by sonication, followed by a direct determination using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The linearity of the instrumental response was good, with average regression coefficients of 0.9971 and 0.9979 for PFOS and PFOA, respectively, and the coefficients of variation (CV) of the method ranged from 8% to 20%. Limits of detection (LOD) were 0.04 ng/g for both the analytes and recoveries were 90% for PFOS and 76% for PFOA. The method was applied to samples of homogenized fillets of wild and farmed fish from the Mediterranean Sea. Most of the samples showed little or no contamination by perfluorooctane sulfonate and perfluorooctanoic acid, and the highest concentrations detected among the fish species analyzed were, respectively, 5.96 ng/g and 1.89 ng/g. The developed analytical methodology can be used as a tool to monitor and to assess human exposure to perfluorinated compounds through sea food consumption.

  8. Liquid Chromatography-Tandem Mass Spectrometry Analysis of Perfluorooctane Sulfonate and Perfluorooctanoic Acid in Fish Fillet Samples

    Directory of Open Access Journals (Sweden)

    Viviana Paiano

    2012-01-01

    Full Text Available Perfluorooctane sulfonate (PFOS and perfluorooctanoic (PFOA acid are persistent contaminants which can be found in environmental and biological samples. A new and fast analytical method is described here for the analysis of these compounds in the edible part of fish samples. The method uses a simple liquid extraction by sonication, followed by a direct determination using liquid chromatography-tandem mass spectrometry (LC-MS/MS. The linearity of the instrumental response was good, with average regression coefficients of 0.9971 and 0.9979 for PFOS and PFOA, respectively, and the coefficients of variation (CV of the method ranged from 8% to 20%. Limits of detection (LOD were 0.04 ng/g for both the analytes and recoveries were 90% for PFOS and 76% for PFOA. The method was applied to samples of homogenized fillets of wild and farmed fish from the Mediterranean Sea. Most of the samples showed little or no contamination by perfluorooctane sulfonate and perfluorooctanoic acid, and the highest concentrations detected among the fish species analyzed were, respectively, 5.96 ng/g and 1.89 ng/g. The developed analytical methodology can be used as a tool to monitor and to assess human exposure to perfluorinated compounds through sea food consumption.

  9. Simultaneous identification of abused drugs, benzodiazepines, and new psychoactive substances in urine by liquid chromatography tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Hei-Hwa Lee

    2016-03-01

    Full Text Available A literature search reveals no studies concerning simultaneous identification of commonly abused drugs, benzodiazepines, and new psychoactive substances in urine by liquid chromatography tandem mass spectrometry (LC–MS/MS. We developed and validated an LC–MS/MS method for simultaneous identification of multiple abused drugs, benzodiazepines, and new psychoactive substances in urine from suspected drug abusers. The instrument was operated in multiple-reaction monitoring using an electrospray ionization mode. Chromatograms were separated using an ACE5 C18 column on a gradient of acetonitrile. After liquid–liquid extraction, samples were passed through a 0.22-μm polyvinylidene difluoride filter before injection into the LC–MS/MS. The limits of quantitation ranged from 0.5 ng/mL to 31.3 ng/mL. The linearity ranged from 0.5 ng/mL to 200 ng/mL. The precision results were below 15.4% (intraday and 18.7% (interday. The intraday accuracy ranged from 85.9% to 121.0%; interday accuracy ranged from 66.1% to 128.7%. The proposed method was applied to 769 urine samples. The most common three drugs identified were ketamine, amphetamine, and opiates. The drug positive rate for one or more drugs was 79.6%. Our results demonstrate the suitability of the LC–MS/MS method for simultaneous identification of multiple abused drugs, benzodiazepines, and new psychoactive substances in urine.

  10. Simultaneous determination of water-soluble vitamins in selected food matrices by liquid chromatography/electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Gentili, Alessandra; Caretti, Fulvia; D'Ascenzo, Giuseppe; Marchese, Stefano; Perret, Daniela; Di Corcia, Daniele; Rocca, Lucia Mainero

    2008-07-01

    A rapid, simple and sensitive method based on liquid chromatography/tandem mass spectrometry (LC/MS/MS) with an electrospray ionization (ESI) source for the simultaneous analysis of fourteen water-soluble vitamins (B1, B2, two B3 vitamers, B5, five B6 vitamers, B8, B9, B12 and C) in various food matrices, i.e. maize flour, green and golden kiwi and tomato pulp, is presented here. Analytes were separated by ion-suppression reversed-phase liquid chromatography in less than 10 min and detected in positive ion mode. Sensitivity and specificity of this method allowed two important results to be achieved: (i) limits of detection of the analytes at ng g(-1) levels (except for vitamin C); (ii) development of a rapid sample treatment that minimizes analyte exposition to light, air and heat, eliminating any step of extract concentration. Analyte recovery depended on the type of matrix. In particular, recovery of the analytes in maize flour was > or =70%, with the exception of vitamin C, pyridoxal-5'-phosphate and vitamin B9 (ca 40%); with tomato pulp, recovery was > or =64%, except for vitamin C (41%); with kiwi, recovery was > or =73%, except for nicotinamide (ca. 30%).

  11. Simultaneous quantitative analysis of dextromethorphan, dextrorphan and chlorphenamine in human plasma by liquid chromatography-electrospray tandem mass spectrometry.

    Science.gov (United States)

    Ding, Ying; Huang, Kai; Chen, Lan; Yang, Jie; Xu, Wen-Yan; Xu, Xue-Jiao; Duan, Ru; Zhang, Jing; He, Qing

    2014-03-01

    A sensitive and accurate HPLC-MS/MS method was developed for the simultaneous determination of dextromethorphan, dextrorphan and chlorphenamine in human plasma. Three analytes were extracted from plasma by liquid-liquid extraction using ethyl acetate and separated on a Kromasil 60-5CN column (3 µm, 2.1 × 150 mm) with mobile phase of acetonitrile-water (containing 0.1% formic acid; 50:50, v/v) at a flow rate of 0.2 mL/min. Quantification was performed on a triple quadrupole tandem mass spectrometer in multiple reaction monitoring mode using positive electrospray ionization. The calibration curve was linear over the range of 0.01-5 ng/mL for dextromethorphan, 0.02-5 ng/mL for dextrorphan and 0.025-20 ng/mL for chlorphenamine. The lower limits of quantification for dextromethorphan, dextrorphan and chlorphenamine were 0.01, 0.02 and 0.025 ng/mL, respectively. The intra- and inter-day precisions were within 11% and accuracies were in the range of 92.9-102.5%. All analytes were proved to be stable during sample storage, preparation and analytic procedures. This method was first applied to the pharmacokinetic study in healthy Chinese volunteers after a single oral dose of the formulation containing dextromethorphan hydrobromide (18 mg) and chlorpheniramine malaeate (8 mg). Copyright © 2013 John Wiley & Sons, Ltd.

  12. Pesticide residue determination in surface waters by stir bar sorptive extraction and liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Giordano, A; Fernández-Franzón, M; Ruiz, M J; Font, G; Picó, Y

    2009-03-01

    In this stir bar sorptive extraction (SBSE) method, 16 pesticides were extracted from surface water samples by sorption onto 1 mm polydimethylsiloxane layer coated on a 10-mm-length stir bar magnet. After liquid desorption of the analytes with 1 ml of methanol, the detection was performed on a liquid chromatography-tandem mass spectrometry with a triple quadrupole (QqQ) analyzer using selected reaction monitoring mode via electrospray ionization. Parameters affecting SBSE operation, including sample volume, salt addition, extraction time, stirring rate, and desorption conditions, have been evaluated. The optimized SBSE method required two 50 ml aliquots of surface water samples, one aliquot was added of 30% NaCl and stirred at 900 rpm during 1 h for testing five pesticides with log K(o/w) 3. The method was validated in spiked surface water samples at limits of quantifications (LOQs) and ten times the LOQs showing recoveries Albufera Lake and surrounding channels, showing that SBSE is a powerful tool for routine control analysis of pesticide residues in surface water.

  13. Quantitation of α-Lactalbumin by Liquid Chromatography Tandem Mass Spectrometry in Medicinal Adjuvant Lactose

    Directory of Open Access Journals (Sweden)

    Rui Yan

    2014-01-01

    Full Text Available Lactose is a widely used pharmaceutical excipient, sometimes irreplaceable. Traces of residual proteins left during production of lactose are potential allergen to body. The present paper describes a sensitive and specific LC-MS method for the determination of α-lactalbumin (α-La in lactose samples. Chromatographic separation was performed on an Acquity UPLC BEH300 C18 column (2.1×150 mm, 1.7 μm with an isocratic mobile phase consisting of water containing 0.1% TFA and acetonitrile containing 0.1% TFA (80 : 20, v/v. Mass spectrometric detection was achieved by a triple-quadrupole mass spectrometer equipped with an ESI interface operating in positive ionization mode. Quantitation was performed using selected ion monitoring of m/z 2364 for α-La. The calibration curve was linear from 0.2 to 10 µg/mL. The intra- and interday precisions were less than 7.6% and the accuracy ranged from 96.4 to 104.5%. The limit of quantification (LOQ was 0.15 µg/mL and the limit of detection (LOD was 0.05 µg/mL. This method was then successfully applied to investigate 6 different lactose samples. The application can provide technical preparation for the development of specification of lactose.

  14. Simultaneous quantification of reparixin and paclitaxel in plasma and urine using ultra performance liquid chromatography-tandem mass spectroscopy (UHPLC-MS/MS): Application to a preclinical pharmacokinetic study in rats.

    Science.gov (United States)

    Malhi, Sarandeep; Stesco, Nicholas; Alrushaid, Samaa; Lakowski, Ted M; Davies, Neal M; Gu, Xiaochen

    2017-03-01

    A liquid chromatography-tandem mass spectroscopy (LC-MS/MS) assay was developed and validated to simultaneously quantify anticancer drugs reparixin and paclitaxel in this study. The compounds were extracted from plasma and urine samples by protein precipitation with acetone (supplemented with 0.1% formic acid). Chromatographic separation was achieved using a C18 column, and drug molecules were ionized using dual ion source electrospray and atmospheric pressure chemical ionization (DUIS: ESI-APCI). Reparixin and paclitaxel were quantified using negative and positive multiple reaction monitoring (MRM) mode, respectively. Stable isotope palcitaxel-D5 was used as the internal standard (IS). The assay was validated for specificity, recovery, carryover and sample stability under various storage conditions; it was also successfully applied to measure drug concentrations collected from a pharmacokinetic study in rats. The results confirmed that the assay was accurate and simple in quantifying both reparixin and paclitaxel in plasma and urine with minimal sample pretreatment. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Simultaneous determination of aflatoxin B₁, B₂, G₁, and G₂ in corn powder, edible oil, peanut butter, and soy sauce by liquid chromatography with tandem mass spectrometry utilizing turbulent flow chromatography.

    Science.gov (United States)

    Fan, Sufang; Li, Qiang; Zhang, Xiaoguang; Cui, Xiaobin; Zhang, Dongsheng; Zhang, Yan

    2015-05-01

    A novel fully automated method based on dual column switching using turbulent flow chromatography followed by liquid chromatography with tandem mass spectrometry was developed for the determination of aflatoxin B1 , B2 , G1 , and G2 in corn powder, edible oil, peanut butter, and soy sauce samples. After ultrasound-assisted extraction, samples were directly injected to the chromatographic system and the analytes were concentrated into the clean-up loading column. Through purge switching, the analytes were transferred to the analytical column for subsequent detection by mass spectrometry. Different types of TurboFlow(TM) columns, transfer flow rate, transfer time were optimized. The limits of detection and quantification of this method ranged between 0.2-2.0 and 0.5-4.0 μg/kg for aflatoxins in different matrixes, respectively. Recoveries of aflatoxins were in range of 83-108.1% for all samples, matrix effects were in range of 34.1-104.7%. The developed method has been successfully applied in the analysis of aflatoxin B1 , B2 , G1 , and G2 in real samples. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Development and Validation of a Liquid Chromatography-Tandem Mass Spectrometry Method Coupled with Dispersive Solid-Phase Extraction for Simultaneous Quantification of Eight Paralytic Shellfish Poisoning Toxins in Shellfish

    Science.gov (United States)

    Yang, Xianli; Zhou, Lei; Tan, Yanglan; Shi, Xizhi; Zhao, Zhiyong; Nie, Dongxia; Zhou, Changyan; Liu, Hong

    2017-01-01

    In this study, a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was developed for simultaneous determination of eight paralytic shellfish poisoning (PSP) toxins, including saxitoxin (STX), neosaxitoxin (NEO), gonyautoxins (GTX1–4) and the N-sulfo carbamoyl toxins C1 and C2, in sea shellfish. The samples were extracted by acetonitrile/water (80:20, v/v) with 0.1% formic and purified by dispersive solid-phase extraction (dSPE) with C18 silica and acidic alumina. Qualitative and quantitative detection for the target toxins were conducted under the multiple reaction monitoring (MRM) mode by using the positive electrospray ionization (ESI) mode after chromatographic separation on a TSK-gel Amide-80 HILIC column with water and acetonitrile. Matrix-matched calibration was used to compensate for matrix effects. The established method was further validated by determining the linearity (R2 ≥ 0.9900), average recovery (81.52–116.50%), sensitivity (limits of detection (LODs): 0.33–5.52 μg·kg−1; limits of quantitation (LOQs): 1.32–11.29 μg·kg−1) and precision (relative standard deviation (RSD) ≤ 19.10%). The application of this proposed approach to thirty shellfish samples proved its desirable performance and sufficient capability for simultaneous determination of multiclass PSP toxins in sea foods. PMID:28661471

  17. A novel ultra high-performance liquid chromatography-tandem mass spectrometry method for the simultaneous determination of xanthones and steroidal saponins in crude and salt-processed Anemarrhenae Rhizoma aqueous extracts.

    Science.gov (United States)

    Ji, De; Su, Xiaonan; Huang, Ziyan; Wang, Qiaohan; Lu, Tulin

    2018-06-01

    We established a rapid and sensitive ultra high-performance liquid chromatography tandem mass spectrometry method for the simultaneous quantification of xanthones and steroidal saponins in rat plasma. Chromatographic separation was achieved on a C 18 column with a mobile phase comprising acetonitrile and 0.1% formic acid. The detection was performed by negative electrospray ionization in multiple reaction monitoring mode. The validated method showed good linearity within the tested range (r > 0.9945). The intra- and interday precision at high, medium, and low concentrations was less than 7.96%. The bias of accuracies ranged from -1.92 to 9.62%. The extraction recoveries of the compounds ranged from 84.78 to 88.69%, and the matrix effects ranged from 96.76 to 108.59%. This method was successfully applied to a pharmacokinetic comparison of crude and salt-processed Anemarrhenae Rhizoma aqueous extracts after oral administration in rats. The maximum plasma concentration and area under concentration-time curve of timosaponin BIII and timosaponin AIII increased significantly (P < 0.05 or 0.01) and those of timosaponin BII decreased significantly (P < 0.05) after processing. These results could contribute to the clinical application of crude and salt-processed Anemarrhenae Rhizoma and reveal the processing mechanism. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Simultaneous determination of carboprost methylate and its active metabolite carboprost in dog plasma by liquid chromatography-tandem mass spectrometry with positive/negative ion-switching electrospray ionization and its application to a pharmacokinetic study.

    Science.gov (United States)

    Yin, Lei; Meng, Xiangjun; Zhou, Xiaotong; Zhang, Tinglan; Sun, Heping; Yang, Zhichao; Yang, Bo; Xiao, Ning; Fawcett, J Paul; Yang, Yan; Gu, Jingkai

    2015-08-15

    A liquid chromatography-tandem mass spectrometric (LC-MS/MS) method using positive/negative electrospray ionization (ESI) switching for the simultaneous quantitation of carboprost methylate and carboprost in dog plasma has been developed and validated. After screening, the esterase inhibitor, dichlorvos was added to the whole blood at a ratio of 1:99 (v/v) to stabilize carboprost methylate during blood collection, sample storage and LLE. Indomethacin was added to plasma to inhibit prostaglandins synthesis after sampling. After liquid-liquid extraction of 500μL plasma with ethyl ether-dichloromethane (75:25, v/v), analytes and internal standard (IS), alprostadil-d4, were chromatographed on a CAPCELL PAK Phenyl column (150×2.0mm, 5μm) using acetonitrile-5mM ammonium acetate as mobile phase. Carboprost methylate was detected by positive ion electrospray ionization followed by multiple reaction monitoring (MRM) of the transition at m/z 400.5→329.3; the carboprost and IS were detected by negative ion electrospray ionization followed by MRM of the transitions at m/z 367.2→323.2, and 357.1→321.2, respectively. The method was linear for both analytes in the concentration range 0.05-30ng/mL with intra- and inter-day precisions (as relative standard deviation) of ≤6.75% and accuracy (as relative error) of ≤7.21% and limit of detection (LOD) values were 10 and 20pg/mL, respectively. The method was successfully applied to a pharmacokinetic study of the analytes in beagle dogs after intravaginal administration of a suppository containing 0.5mg carboprost methylate. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. A comparative pharmacokinetic study of three flavonoids and three anthraquinones in normal and gastrointestinal motility disorders rat plasma after the oral administration of Wei-Chang-Shu tablet using high-performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Ren, Yan; Zhao, Weiwei; Zhao, Juanjuan; Chen, Xiangming; Yu, Chen; Liu, Mengan

    2017-11-01

    A simple, fast and reliable high-performance liquid chromatography-tandem mass spectrometry method was developed and validated for the simultaneous quantification and pharmacokinetic study of three flavonoids (liquiritigenin, isoliquiritigenin and formononetin) and three anthraquinones (emodin, rhein and aloe-emodin), which are the bioactive ingredients of Wei-Chang-Shu tablet found in rat plasma. After extraction by liquid-liquid extraction with ethyl acetate, chromatographic separation was achieved on an Agilent Zorbax SB-C 18 column (4.6 × 150 mm, 5 μm) at a flow rate of 1 mL/min by gradient elution using 0.1% aqueous acetic acid and acetonitrile. The detection was performed using a triple quadrupole mass spectrometer equipped with electrospray ionization source in the negative ionization and selected reaction monitoring mode. Method validation was performed in terms of specificity, carryover, linearity (r > 0.99), intra-/inter-day precision (1.0-10.1%), accuracy (relative error, <7.6%), stability (0.6-13.2%), extract recovery (74.9-91.9%) and matrix effect (89.1-109%). The lower limits of quantification of the six analytes varied from 0.92 to 10.4 ng/mL. The validated method was successfully applied to compare the pharmacokinetic properties of Wei-Chang-Shu tablet in normal rats and in rats with gastrointestinal motility disorders. The results indicated that there were obvious differences in the pharmacokinetic behavior between normal and model rats. This study will be helpful in the clinical application of Wei-Chang-Shu tablet. Copyright © 2017 John Wiley & Sons, Ltd.

  20. Application of Chromatographic and Electrophoretic Methods for the Analysis of Imidazolium and Pyridinium Cations as Used in Ionic Liquids

    Directory of Open Access Journals (Sweden)

    P. Stepnowski

    2006-11-01

    Full Text Available Interest in ionic liquids for their potential in different chemical processes isconstantly increasing, as they are claimed to be environmentally benign – excellent, non-volatile solvents for a wide range of applications. The wide applicability of thesecompounds also demands reliable, relatively simple and reproducible analytical techniques.These methods must be applicable not only to different technical or natural matrices but alsoto the very low concentrations that are likely to be present in biological and environmentalsystems. In this review, therefore, methods for separating and analysing imidazolium- andpyridinium-type ionic liquids in aqueous matrices using high performance liquidchromatography (HPLC and capillary electrophoresis (CE are examined. The techniquesfor identifying ionic liquids are meant primarily to track the concentrations of ionic liquidsas residues not only in products and wastes but also in biological or environmental samples.The application of hyphenated techniques in this field is intended to selectively separate thequaternary entity from other cationic and non-ionic species present in the matrix, and toenable its fine-scale quantification. Nowadays, methods developed for cation analysis arebased mostly on reversed-phase high-performance liquid chromatography, ionchromatography, ion-pair chromatography and capillary electrophoresis, where variousbuffered mobile phases are used.

  1. Optimisation and characterisation of silica-based reversed-phase liquid chromatographic systems for the analysis of basic pharmaceuticals

    NARCIS (Netherlands)

    Vervoort, R.J.M.; Debets, A.J.J.; Claessens, H.A.; Cramers, C.A.M.G.; Jong, de G.J.

    2000-01-01

    Reversed-phase liquid chromatography using silica-based columns is successfully applied in many separations. However, also some drawbacks exist, i.e. the analysis of basic compounds is often hampered by ionic interaction of the basic analytes with residual silanols present on the silica surface,

  2. Method development for liquid chromatographic/triple quadrupole mass spectrometric analysis of trace level perfluorocarboxylic acids in articles of commerce

    Science.gov (United States)

    An analytical method to identify and quantify trace levels of C5 to C12 perfluorocarboxylic acids (PFCAs) in articles of commerce (AOC) is developed and rigorously validated. Solid samples were extracted in methanol, and liquid samples were diluted with a solvent consisting of 60...

  3. Comparison of High Performance Liquid Chromatography with Fluorescence Detector and with Tandem Mass Spectrometry methods for detection and quantification of Ochratoxin A in green and roasted coffee beans

    Directory of Open Access Journals (Sweden)

    Raquel Duarte da Costa Cunha Bandeira

    2013-12-01

    Full Text Available Two analytical methods for the determination and confirmation of ochratoxin A (OTA in green and roasted coffee samples were compared. Sample extraction and clean-up were based on liquid-liquid phase extraction and immunoaffinity column. The detection of OTA was carried out with the high performance liquid chromatography (HPLC combined either with fluorescence detection (FLD, or positive electrospray ionization (ESI+ coupled with tandem mass spectrometry (MS-MS. The results obtained with the LC-ESI-MS/MS were specific and more sensitive, with the advantages in terms of unambiguous analyte identification, when compared with the HPLC-FLD.

  4. Simultaneous determination of 9 heterocyclic aromatic amines in pork products by liquid chromatography coupled with triple quadrupole tandem mass spectrometry

    Science.gov (United States)

    Shen, X. C.; Zhang, Y. L.; Cui, Y. Q.; Xu, L. Y.; Li, X.; Qi, J. H.

    2017-07-01

    Heterocyclic aromatic amines (HAAs) are potent mutagens that formed at high temperature in cooked, protein-rich food. Owing to their frequent intake, an accurate method is essential to access human health risk of HAAs exposure through detecting these compounds in various heat-treated meat products. In this study, a liquid chromatography-electrospray tandem mass spectrometry (LC--ESI-MS/MS) method was developed to perform the determination of 9 mutagenic heterocyclic amines (HAAs) in meat samples with multiple reaction monitoring (MRM) mode. Ultrasound assisted extraction and diatomaceous earth was employed to extract HAAs from food samples, and the analytes were purified and enriched using tandem solid phase extraction, with propyl sulfonic acid coupled to a C18 cartridge. Two parameters, extraction time and eluent, were carefully optimized to improve the extraction and purification efficiency. The LC separation was carried out using a Zorbax SB-C18 (3.5 μm particle size, 2.1 × 150 mm i.d.) column and optimized some parameters, such as pH, concentration and volume. Under the optimal experimental conditions, recoveries ranged from 52.97% to 97.11% with good quality parameters: limit of detection values between 0.02 and 0.24 ng mL-1, linearity (R2>0.998), and run-to-run and day-to-day precisions lower than 9.81% achieved. To evaluate the performance of the method in high throughput analysis of complex meat samples, the LC-MS/MS method was applied to the analysis of HAAs in three food samples, and the results demonstrated that the method can be used for the trace determination of HAAs in pork samples.

  5. Quantitative determination of hederagenin in rat plasma and cerebrospinal fluid by ultra fast liquid chromatography-tandem mass spectrometry method.

    Science.gov (United States)

    Yang, Xuemei; Li, Guoliang; Chen, Lingyun; Zhang, Cong; Wan, Xinxiang; Xu, Jiangping

    2011-07-01

    A rapid, sensitive and selective method was developed for the quantitative determination of hederagenin in rat plasma and cerebrospinal fluid (CSF) by ultra fast liquid chromatography-tandem mass spectrometry (UFLC-MS/MS). It has been successfully applied in a pharmacokinetic study of hederagenin in the central nervous system (CNS). Sample pretreatment involved a simple protein precipitation with methanol and a one-step extraction with ethyl acetate. Separation was carried out in a Shim-pack XR-ODS II (75 mm × 2.0 mm, i.d., 2.1 μm) column with gradient elution at a flow rate of 0.35 mL/min. The mobile phase was 5mM ammonium acetate and acetonitrile. Detection was performed in a triple-quadruple tandem mass spectrometer by multiple-reaction-monitoring mode via electrospray ionization. A linear calibration curve for hederagenin was obtained over a concentration range of 0.406 (lower limit of quantification, LLOQ) to 203 ng/mL (r² > 0.99) for both plasma and CSF. The intra-day and inter-day precision (relative standard deviation, RSD) values were less than 15%. At all quality control (QC) levels, the accuracy (relative error, RE) was within -9.0% and 11.1% for plasma and CSF, respectively. The pharmacokinetics results indicated that hederagenin could pass through the blood-brain barrier. This UFLC-MS/MS method demonstrates higher sensitivity and sample throughput than previous methods. It was also successfully applied to the pharmacokinetic study of hederagenin following oral administration of Fructus akebiae extract in rats. Copyright © 2011 Elsevier B.V. All rights reserved.

  6. Determination of pharmaceutical and illicit drugs in oral fluid by ultra-high performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Di Corcia, D; Lisi, S; Pirro, V; Gerace, E; Salomone, A; Vincenti, M

    2013-05-15

    A simple and extremely fast procedure for the quantitative determination in oral fluid samples of 44 substances, including the most common drugs of abuse and several pharmaceutical drugs, was developed and fully validated. Preliminary sample treatment was limited to protein precipitation. The resulting acetonitrile solution was directly injected into an ultra-high performance liquid chromatograph (UHPLC) equipped with a C18 column (100mm×2.1mm, 1.7μm). The mobile phase eluted with linear gradient (water/formic acid 5mM: acetonitrile/formic acid 5mM; v:v) from 98:2 to 0:100 in 5.0min, followed by isocratic elution at 100% B for 1.0min. The flow rate was 0.6mL/min and the total run time was 9.0min including re-equilibration at the initial conditions. The analytes were revealed by a triple quadrupole mass spectrometer operating in the selected reaction monitoring mode. The method proved to be simple, accurate, rapid and highly sensitive, allowing the simultaneous detection of all compounds. The ease of sample treatment, together with the wide range of detectable substances, all with remarkable analytical sensitivity, make this procedure ideal for the screening of large populations in several forensic and clinical contexts, whenever oral fluid sampling has to be preferred to blood sampling, as for example in short retrospective investigations. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. New high performance liquid chromatographic method for simultaneous determination of diclofenac and meloxicam in oral formulation of liposomes and human plasma

    International Nuclear Information System (INIS)

    Madni, A.; Ahmad, M.; Usman, M.; Zubair, M.M.; Shoiab, H.M.; Khan, S.A.; Qureshi, M.S.

    2010-01-01

    A new, easy and consistent reversed-phase high-performance liquid chromatographic method with diode array detection has been developed and validated for the simultaneous determination of diclofenac potassium (DP) and meloxicam (MLX) in liposome, marketed brands and human plasma. Microextraction method based on liquid-liquid extraction principal was used to extract drug from plasma matrix. The optimized mobile phase was used in the molar ratio of 20:20:60 (v/v/v) mixture of acetonitrile, methanol and 20 x 10/sup -3/ M potassium dihydrogen phosphate buffer (pH 3.7), pumped at an optimized flow rate of 1.0 mL.min/sup -1/. The linearity was performed in the concentration range of 15 ng.mL/sup -1/ to 10 mu g.mL/sup -1/ with gamma/sup 2/ of 0.9989 +- 0.13 and 0.9979 +- 0.11 (n = 6) for DP and MLX, respectively. The assay was repeatable at concentration levels of 10 ng.mL/sup -1/, 1 mu g.mL/sup -1/ and 10 mu g.mL/sup -1/ with coefficient of variation of 0.168 - 0.603% for 10 ng.mL-1 (DP), 15 ng.mL/sup -/1 (MLX) and 1 mu g.mL/sup -1/ and 10 mu g.mL/sup -1/ for DP and MLX. The LOD values were 3 and 5 ng.mL/sup -1/, while values of LOQ were 10 and 15 ng.mL/sup =11, for DP and MLX. The present method is applicable in routine quality control operations, advanced drug delivery formulations (Liposomes) and in human Plasma samples for pharmacokinetics and bioequivalence studies. (author)

  8. Determination of ribavirin in human serum using liquid chromatography tandem mass spectrometry

    NARCIS (Netherlands)

    van der Lijke, H.; Alffenaar, J.-W. C.; Kok, W.Th.; Greijdanus, B.; Uges, D.R.A.

    2012-01-01

    A method has been developed for the determination of ribavirin in human serum for therapeutic drug monitoring purposes, using liquid chromatography electrospray ionization mass spectrometry. Separation was obtained with a mobile phase gradient starting and ending in 100% aqueous conditions using a

  9. Simultaneous determination of seven flavonoids in Epimedium by liquid chromatography-tandem mass spectrometry method

    Institute of Scientific and Technical Information of China (English)

    Cai Sheng Wu; Bao Lin Guo; Yu Xin Sheng; Jin Lan Zhang

    2008-01-01

    In this paper, a sensitive and specific liquid chromatography-electrospray ionisation-mass spectrometry (LC-ESI-MS) method has been developed and validated for the identification and determination of seven flavonoids, namely epimedin A, epimedin B, epimedin C, icariin, sagittatoside B, 2"-0-rhamnosyl icariside II, and baohuoside I in Epimedium from different sources.

  10. Analysis of 2-methylthio-derivatives of isoprenoid cytokinins by liquid chromatography-tandem mass spectrometry

    Czech Academy of Sciences Publication Activity Database

    Tarkowski, Petr; Václavíková, Kateřina; Novák, Ondřej; Pertry, I.; Hanuš, Jan; Whenham, R.; Vereecke, D.; Šebela, M.; Strnad, Miroslav

    2010-01-01

    Roč. 680, 1-2 (2010), s. 86-91 ISSN 0003-2670 R&D Projects: GA ČR GA301/08/1649 Institutional research plan: CEZ:AV0Z50380511 Keywords : Cytokinins * Rhodococcus fascians * High-performance liquid chromatography Subject RIV: CE - Biochemistry Impact factor: 4.310, year: 2010

  11. Simultaneous determination of seven anticoagulant rodenticides in agricultural products by gel permeation chromatography and liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Saito-Shida, Shizuka; Nemoto, Satoru; Matsuda, Rieko; Akiyama, Hiroshi

    2016-11-01

    A sensitive and reliable method for the simultaneous determination of hydroxycoumarin-type (brodifacoum, bromadiolone, coumatetralyl, and warfarin) and indandione-type (chlorophacinone, diphacinone, and pindone) rodenticides in agricultural products by gel permeation chromatography (GPC) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed. The procedure involved extraction of the rodenticides from samples with acetone, followed by liquid-liquid partitioning with hexane/ethyl acetate (1:1, v/v) and 10% sodium chloride aqueous solution, then cleanup using GPC, and finally, analysis using LC-MS/MS. High recoveries from the GPC column were obtained for all rodenticides tested using a mobile phase of acetone/cyclohexane/triethylamine (400:1600:1, v/v/v). An ODS column, which contains low levels of metal impurities, gave satisfactory peak shapes for both hydroxycoumarin- and indandione-type rodenticides in the LC-MS/MS separation. The average recoveries of rodenticides from eight agricultural foods (apple, eggplant, cabbage, orange, potato, tomato, brown rice, and soybean) fortified at 0.0005-0.001 mg/kg ranged from 76 to 116%, except for bromadiolone in orange (53%) and diphacinone in soybean (54%), and the relative standard deviations ranged from 1 to 16%. The proposed method effectively removed interfering components, such as pigments and lipids, and showed high selectivity. In addition, the matrix effects were negligible for most of the rodenticide/food combinations. The results suggest that the proposed method is reliable and suitable for determining hydroxycoumarin- and indandione-type rodenticides in agricultural products.

  12. Multiclass mycotoxin analysis in edible oils using a simple solvent extraction method and liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Eom, Taeyong; Cho, Hyun-Deok; Kim, Junghyun; Park, Mihee; An, Jinyoung; Kim, Moosung; Kim, Sheen-Hee; Han, Sang Beom

    2017-11-01

    A simple and rapid method for the simultaneous determination of 11 mycotoxins - aflatoxins B 1 , B 2 , G 1 and G 2 ; fumonisins B 1 , B 2 and B 3 ; ochratoxin A; zearalenone; deoxynivalenol; and T-2 toxin - in edible oils was established using liquid chromatography tandem mass spectrometry (LC-MS/MS). In this study, QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe), QuEChERS with dispersive liquid-liquid microextraction, and solvent extraction were examined for sample preparation. Among these methods, solvent extraction with a mixture of formic acid/acetonitrile (5/95, v/v) successfully extracted all target mycotoxins. Subsequently, a defatting process using n-hexane was employed to remove the fats present in the edible oil samples. Mass spectrometry was carried out using electrospray ionisation in polarity switchi