WorldWideScience

Sample records for lingual bolus propulsion

  1. Swallowing Disorders in Parkinson's Disease: Impact of Lingual Pumping

    Science.gov (United States)

    Argolo, Natalie; Sampaio, Marília; Pinho, Patrícia; Melo, Ailton; Nóbrega, Ana Caline

    2015-01-01

    Background: Lingual pumping (LP) is a repetitive, involuntary, anteroposterior movement of the tongue on the soft palate that is executed prior to transferring the food bolus to the pharynx, but we also observed LP when multiple swallows were taken. LP may be associated with rigidity and bradykinesia in patients with Parkinson's disease (PD). This…

  2. Lingual biomechanics, case selection and success

    Directory of Open Access Journals (Sweden)

    Sanjay Labh

    2016-01-01

    Full Text Available Deeper understanding of lingual biomechanics is prerequisite for success with lingual appliance. The difference between labial and lingual force system must be understood and kept in mind during treatment planning, especially anchorage planning, and extraction decision-making. As point of application of force changes, it completely changes the force system in all planes. This article describes lingual biomechanics, anchorage planning, diagnostic considerations, treatment planning, and case selection criteria in lingual orthodontics.

  3. Lingual Thyroid & its Management

    OpenAIRE

    Thiagarajan, Balasubramanian

    2017-01-01

    This e book discusses the topic Lingual thyroid. Lingual thyroid is a rare disorders seen only in 1 in 1 lakh population. This is actually a coincidental finding in most of the cases. This book discusses the embryological aspects of lingual thyroid, clinical features and the current management trends of the same. This record was migrated from the OpenDepot repository service in June, 2017 before shutting down.

  4. [A case of lingual agenesis].

    Science.gov (United States)

    Carinci, F; Felisatti, P; Curioni, C

    1996-01-01

    Lingual agenesis is a rare anomaly caused by failed morphogenesis of the lateral lingual swellings during embriogenesis. Most reported cases have been part of oromandibular limb hypogenesis syndrome (OLHS). A case of lingual agenesis associated with micrognathia and alteration of the hands is reported.

  5. Piezosurgery for the Lingual Split Technique in Lingual Positioned Impacted Mandibular Third Molar Removal

    Science.gov (United States)

    Ge, Jing; Yang, Chi; Zheng, Jiawei; Qian, Wentao

    2016-01-01

    Abstract The aim of this study was to evaluate the effect and safety of lingual split technique using piezosurgery for the extraction of lingual positioned impacted mandibular 3rd molars with the goal of proposing a more minimally invasive choice for this common surgery. Eighty-nine consecutive patients with 110 lingual positioned impacted mandibular 3rd molars requiring extraction were performed the lingual split technique using piezosurgery. One sagittal osteotomy line and 2 transverse osteotomy line were designed for lingual and occlusal bone removal. The success rate, operative time, postoperative outcome, and major complications (including nerve injury, mandible fracture, severe hematoma or edema, and severe pyogenic infection) were documented and analyzed. All impacted mandibular 3rd molars were successfully removed (110/110). The average time of operation was 14.6 minutes (ranged from 7 to 28 minutes). One hundred and seven extraction sites (97.3%) were primary healing. Pain, mouth opening, swelling, and PoSSe scores on postoperative 7-day were 0.34 ± 0.63, 3.88 ± 0.66(cm), 2.4 ± 0.2(cm), and 23.7 ± 5.9, respectively. There were 6 cases (5.5%) had lingual nerve disturbance and 3 cases (2.7%) developed inferior alveolar nerve impairment, and achieved full recovery within 2 months by neurotrophic drug treatment. Our study suggested piezosurgery for lingual split technique provided an effective way for the extraction of lingual positioned and deeply impacted mandibular 3rd molar. PMID:27015214

  6. Lingual orthodontic education: An insight

    Directory of Open Access Journals (Sweden)

    Surya Kanta Das

    2016-01-01

    Full Text Available Despite increasing demand for lingual orthodontics, the technique is not very popular among the orthodontists in general. Lingual orthodontics differs from the conventional labial technique in all aspects. Lack of comprehensive training in this field is a major obstacle in popularizing this science of invisible orthodontics. At present, short-term courses and part-time degree programs are the means to learn this technique and the demand for more comprehensive lingual orthodontic education is on a rise among orthodontists. Lingual orthodontics as a super specialty discipline with full-time residency program can be a step forward. This will groom orthodontists to acquire the finest skills to finish lingual cases but also help to the science to grow with dedicated research work.

  7. Gastrostomy feeding tube - bolus

    Science.gov (United States)

    Feeding - gastrostomy tube - bolus; G-tube - bolus; Gastrostomy button - bolus; Bard Button - bolus; MIC-KEY - bolus ... KEY, 3 to 8 weeks after surgery. These feedings will help your child grow strong and healthy. ...

  8. Computed tomographic angiography study of the relationship between the lingual artery and lingual markers in patients with obstructive sleep apnoea

    Energy Technology Data Exchange (ETDEWEB)

    Hou, T.-N., E-mail: dr-htn@hotmail.co [Department of Otolaryngology Head and Neck Surgery, Affiliated SIR RUN RUN SHAW Hospital, Zhejiang University, Hangzhou 310016 (China); Zhou, L.-N.; Hu, H.-J. [Department of Otolaryngology Head and Neck Surgery, Affiliated SIR RUN RUN SHAW Hospital, Zhejiang University, Hangzhou 310016 (China)

    2011-06-15

    Aim: To determine the relationship between the lingual artery and lingual markers for preoperative evaluation of the lingual artery in patients with obstructive sleep apnoea/hypopnoea syndrome (OSAHS). Methods: A 16-section computed tomographic angiography (CTA) of the lingual artery was performed in 87 inpatient cases with OSAHS, from December 2007 to May 2009. The course of the lingual artery and the anatomic relationship between the lingual artery and the lingual markers were analyzed using CTA imaging. Results: The course of the lingual artery with the tongue in a resting position was similar to that of the Big Dipper constellation (Plough) in the sagittal view of CTA imaging. The first segment of the lingual artery declined approximately 19.27 {+-} 5.24 mm, the middle segment of the lingual artery was forward approximately 19.30 {+-} 6.79 mm, and the ascending segment of the lingual artery rose approximately 52.49 {+-} 10.98 mm. The entry point where the lingual artery entered into the tongue was adjacent to the tip of the greater horn of the hyoid bone. The relationship between the second segment of the lingual artery and the greater horn of the hyoid bone was relatively steady with the tongue in whatever position. The interval between the bilateral greater horn of the hyoid bone equalled that between the bilateral lingual arteries. Conclusions: Recognizing some lingual markers in the patients with OSAHS, such as the greater horn of the hyoid bone, foramen cecum, circumvallate papilla, lingual vein and tongue midline, may facilitate the surgeon's ability to define the course of the lingual artery accurately in the treatment of OSAHS.

  9. Angioleiomioma lingual: A propósito de un caso Lingual angioleiomyoma: A case report

    Directory of Open Access Journals (Sweden)

    I. Peña González

    2008-04-01

    Full Text Available Introducción. Los leiomiomas orales son tumores del músculo liso poco frecuentes debido a la escasez de este tejido en la boca. La forma más frecuente es el angioleiomioma. Son tumoraciones generalmente asintomáticas, que pueden malignizar, por lo que está indicada su extirpación. Su diagnóstico es anatomopatológico siendo importante diferenciarlas de su forma maligna. El tratamiento es quirúrgico y la recidiva inusual. Material y método. Se presenta un caso de angileiomioma lingual y sus características anatomopatológicas, relacionando los hallazgos con la literatura existente Discusión. Los angioleiomiomas linguales son tumoraciones poco frecuentes, generalmente asintomáticas y de fácil acceso quirúrgico. Los hallazgos anatomopatológicos consisten en una proliferación vascular rodeada de un estroma positivo a la actina músculo liso específica. Ha de tenerse en cuenta en el diagnóstico diferencial de masas linguales tales como abscesos, neuromas y tumores de glándulas salivales menores. El tratamiento de elección es quirúrgico y la recidiva inusual. Conclusiones. Los angioleiomiomas linguales son tumores benignos poco frecuentes pero que deben ser tenidos en cuenta en el diagnóstico diferencial de masas linguales. Es importante diferenciarlos de su forma maligna a través de su estudio anatomopatológico.Introduction. Oral leiomyomas are uncommon smooth muscle tumors due to the scant presence of this tissue in the oral cavity. The most common type is angioleiomyoma. Angioleiomyomas usually are asymptomatic tumors that can become malignant, so surgery is necessary. These tumors have a histopathologic diagnosis and the differential diagnosis from their malignant counterparts is important. Surgery is the treatment of choice and recurrence is rare. Material and method. We report a case of lingual angioleiomyoma, its histopathologic findings, and our literature review. Discussion. Lingual angioleiomyomas are tumors that are

  10. Tiroides lingual: un nuevo abordaje quirúrgico Lingual thyroid: a new surgical approach

    Directory of Open Access Journals (Sweden)

    I. Zubillaga Rodríguez

    2004-10-01

    Full Text Available El tiroides lingual es una rara anomalía congénita del desarrollo tiroideo resultante de la ausencia de descenso del mismo desde el foramen caecum hasta la localización prelaríngea habitual. Presentamos el caso de una paciente en edad postmenopáusica con diagnóstico anatomopatológico de tiroides lingual de gran tamaño y localización profunda en la base de la lengua que producía disfagia y dificultad respiratoria crecientes. Asimismo, planteamos un nuevo abordaje quirúrgico para la resección combinando cervicotomía media, pull-through lingual y glosotomía media. Se discuten las distintas pruebas complementarias para llegar a su diagnóstico y se revisan las diferentes técnicas quirúrgicas habitualmente empleadas en su tratamiento concluyendo con las ventajas del abordaje empleado en este caso.Lingual thyroid is an uncommon congenital disorder of thyroid gland development, resulting in a lack of descend of the gland from the foramen caecum to his normal prelaringeal location. In this paper we present a case of a postmenopausic patient presenting with a big size lingual thyroid deeply located in the base of the tongue, suffering increasing disphagia and respiratory impairment. For tumor resection, we chose a surgical approach combining a cervical submental incision, lingual pull- through and midline glossotomy. We discuss the different image studies recommended for proper diagnosis also reviewing the most common surgical techniques used for treatment, as compared with the approach we have described in this case.

  11. Fabrication of universal esthetic lingual button

    Directory of Open Access Journals (Sweden)

    Ramkishore Ratre

    2015-01-01

    Full Text Available Lingual buttons are used in many instances for labial, as well as lingual orthodontics. A simple method is demonstrated to fabricate the lingual buttons chair side. The buttons made are aesthetic as they are made from composite resin and can be successfully bonded anywhere on all tooth surfaces.

  12. Class II malocclusion with complex problems treated with a novel combination of lingual orthodontic appliances and lingual arches.

    Science.gov (United States)

    Yanagita, Takeshi; Nakamura, Masahiro; Kawanabe, Noriaki; Yamashiro, Takashi

    2014-07-01

    This case report describes a novel method of combining lingual appliances and lingual arches to control horizontal problems. The patient, who was 25 years of age at her first visit to our hospital with a chief complaint of crooked anterior teeth, was diagnosed with skeletal Class II and Angle Class II malocclusion with anterior deep bite, lateral open bite, premolar crossbite, and severe crowding in both arches. She was treated with premolar extractions and temporary anchorage devices. Conventionally, it is ideal to use labial brackets simultaneously with appliances, such as a lingual arch, a quad-helix, or a rapid expansion appliance, in patients with complex problems requiring horizontal, anteroposterior, and vertical control; however, this patient strongly requested orthodontic treatment with lingual appliances. A limitation of lingual appliances is that they cannot be used with other conventional appliances. In this report, we present the successful orthodontic treatment of a complex problem using modified lingual appliances that enabled combined use of a conventional lingual arch. Copyright © 2014 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  13. Piezosurgery for the Lingual Split Technique in Lingual Positioned Impacted Mandibular Third Molar Removal: A Retrospective Study.

    Science.gov (United States)

    Ge, Jing; Yang, Chi; Zheng, Jiawei; Qian, Wentao

    2016-03-01

    The aim of this study was to evaluate the effect and safety of lingual split technique using piezosurgery for the extraction of lingual positioned impacted mandibular 3rd molars with the goal of proposing a more minimally invasive choice for this common surgery.Eighty-nine consecutive patients with 110 lingual positioned impacted mandibular 3rd molars requiring extraction were performed the lingual split technique using piezosurgery. One sagittal osteotomy line and 2 transverse osteotomy line were designed for lingual and occlusal bone removal. The success rate, operative time, postoperative outcome, and major complications (including nerve injury, mandible fracture, severe hematoma or edema, and severe pyogenic infection) were documented and analyzed.All impacted mandibular 3rd molars were successfully removed (110/110). The average time of operation was 14.6 minutes (ranged from 7 to 28 minutes). One hundred and seven extraction sites (97.3%) were primary healing. Pain, mouth opening, swelling, and PoSSe scores on postoperative 7-day were 0.34 ± 0.63, 3.88 ± 0.66(cm), 2.4 ± 0.2(cm), and 23.7 ± 5.9, respectively. There were 6 cases (5.5%) had lingual nerve disturbance and 3 cases (2.7%) developed inferior alveolar nerve impairment, and achieved full recovery within 2 months by neurotrophic drug treatment.Our study suggested piezosurgery for lingual split technique provided an effective way for the extraction of lingual positioned and deeply impacted mandibular 3rd molar.

  14. A Simplified Lingual Bracket Positioner

    Directory of Open Access Journals (Sweden)

    Sharath Kumar Shetty

    2014-01-01

    Full Text Available The indirect bonding system for lingual brackets may be broadly classified as; techniques using setup models and those using diagnostic models. The techniques using setup models are more accurate and many of them require the use of lingual bracket positioners for determining the correct position of brackets. We have devised a simpler yet reliable and effective bracket positioner ′Lingual Bracket Positioner′ in our department. Although many variants are available commercially, this design is easy to fabricate, cheap and ready to use.

  15. Anatomical structure of lingual foramen in cone beam computed tomography

    International Nuclear Information System (INIS)

    Ki, Min Woo; Hwang, Eui Hwan; Lee, Sang Rae

    2004-01-01

    To evaluate whether cone beam computed tomography can depict the distribution, position, frequency, relative vertical dimension, and the diameter of the lingual foramen and direction of lingual bone canal. Cone beam computed tomography of mandible was performed on 25 males and 25 females with no history of any orthodontic treatments or any other dental surgeries. A statistical comparison was done on the mean values of males and females. In the location and distribution of lingual foramina, median lingual foramen was found in all subjects and lateral lingual foramen in 58%. In the lateral lingual foramen, bilateral type was found in 28% and unilateral type in 30%. In the number of lingual foramina, median lingual foramen had two foramina and lateral lingual foramen had one foramen, mostly. In the relative mean vertical dimension of lingual foramina, median lingual foramen was 0.03 ± 0.08, and both lateral lingual foramina was 0.20 ± 0.04. The mean diameter of lingual foramina, median lingual foramen was 0.9 mm ± 0.28, right lateral lingual foramen was 0.92 mm ± 0.23, and left lateral lingual foramen was 0.88 mm ± 0.27. The most frequent direction of the lingual bone canals, median lingual bone canal proceeded in anteroinferior direction and lateral lingual bone canal in anterosuperolateral direction. Cone beam computed tomography can be helpful for surgery and implantation on the mandibular area. Radiologist should be aware of this anatomical feature and its possible implications.

  16. Anatomical structure of lingual foramen in cone beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ki, Min Woo; Hwang, Eui Hwan; Lee, Sang Rae [Kyunghee University College of Medicine, Seoul (Korea, Republic of)

    2004-07-15

    To evaluate whether cone beam computed tomography can depict the distribution, position, frequency, relative vertical dimension, and the diameter of the lingual foramen and direction of lingual bone canal. Cone beam computed tomography of mandible was performed on 25 males and 25 females with no history of any orthodontic treatments or any other dental surgeries. A statistical comparison was done on the mean values of males and females. In the location and distribution of lingual foramina, median lingual foramen was found in all subjects and lateral lingual foramen in 58%. In the lateral lingual foramen, bilateral type was found in 28% and unilateral type in 30%. In the number of lingual foramina, median lingual foramen had two foramina and lateral lingual foramen had one foramen, mostly. In the relative mean vertical dimension of lingual foramina, median lingual foramen was 0.03 {+-} 0.08, and both lateral lingual foramina was 0.20 {+-} 0.04. The mean diameter of lingual foramina, median lingual foramen was 0.9 mm {+-} 0.28, right lateral lingual foramen was 0.92 mm {+-} 0.23, and left lateral lingual foramen was 0.88 mm {+-} 0.27. The most frequent direction of the lingual bone canals, median lingual bone canal proceeded in anteroinferior direction and lateral lingual bone canal in anterosuperolateral direction. Cone beam computed tomography can be helpful for surgery and implantation on the mandibular area. Radiologist should be aware of this anatomical feature and its possible implications.

  17. Characterization of swallow modulation in response to bolus volume in healthy subjects accounting for catheter diameter.

    Science.gov (United States)

    Ferris, Lara; Schar, Mistyka; McCall, Lisa; Doeltgen, Sebastian; Scholten, Ingrid; Rommel, Nathalie; Cock, Charles; Omari, Taher

    2018-06-01

    Characterization of the pharyngeal swallow response to volume challenges is important for swallowing function assessment. The diameter of the pressure-impedance recording catheter may influence these results. In this study, we captured key physiological swallow measures in response to bolus volume utilizing recordings acquired by two catheters of different diameter. Ten healthy adults underwent repeat investigations with 8- and 10-Fr catheters. Liquid bolus swallows of volumes 2.5, 5, 10, 20, and 30 mL were recorded. Measures indicative of distension, contractility, and flow timing were assessed. Pressure-impedance recordings with pressure-flow analysis were used to capture key distension, contractility, and pressure-flow timing parameters. Larger bolus volumes increased upper esophageal sphincter distension diameter (P < .001) and distension pressures within the hypopharynx and upper esophageal sphincter (P < .05). Bolus flow timing measures were longer, particularly latency of bolus propulsion ahead of the pharyngeal stripping wave (P < .001). Use of a larger-diameter catheter produced higher occlusive pressures, namely upper esophageal sphincter basal pressure (P < .005) and upper esophageal sphincter postdeglutitive pressure peak (P < .001). The bolus volume swallowed changed measurements indicative of distension pressure, luminal diameter, and pressure-flow timing; this is physiologically consistent with swallow modulation to accommodate larger, faster-flowing boluses. Additionally, catheter diameter predominantly affects lumen occlusive pressures. Appropriate physiological interpretation of the pressure-impedance recordings of pharyngeal swallowing requires consideration of the effects of volume and catheter diameter. NA. Laryngoscope, 128:1328-1334, 2018. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  18. Efficacy of Exclusive Lingual Nerve Block versus Conventional Inferior Alveolar Nerve Block in Achieving Lingual Soft-tissue Anesthesia.

    Science.gov (United States)

    Balasubramanian, Sasikala; Paneerselvam, Elavenil; Guruprasad, T; Pathumai, M; Abraham, Simin; Krishnakumar Raja, V B

    2017-01-01

    The aim of this randomized clinical trial was to assess the efficacy of exclusive lingual nerve block (LNB) in achieving selective lingual soft-tissue anesthesia in comparison with conventional inferior alveolar nerve block (IANB). A total of 200 patients indicated for the extraction of lower premolars were recruited for the study. The samples were allocated by randomization into control and study groups. Lingual soft-tissue anesthesia was achieved by IANB and exclusive LNB in the control and study group, respectively. The primary outcome variable studied was anesthesia of ipsilateral lingual mucoperiosteum, floor of mouth and tongue. The secondary variables assessed were (1) taste sensation immediately following administration of local anesthesia and (2) mouth opening and lingual nerve paresthesia on the first postoperative day. Data analysis for descriptive and inferential statistics was performed using SPSS (IBM SPSS Statistics for Windows, Version 22.0, Armonk, NY: IBM Corp. Released 2013) and a P nerve block in achieving selective anesthesia of lingual soft tissues. It is technically simple and associated with minimal complications as compared to IAN block.

  19. Clinical Anatomy of the Lingual Nerve: A Review.

    Science.gov (United States)

    Sittitavornwong, Somsak; Babston, Michael; Denson, Douglas; Zehren, Steven; Friend, Jonathan

    2017-05-01

    Knowledge of lingual nerve anatomy is of paramount importance to dental practitioners and maxillofacial surgeons. The purpose of this article is to review lingual nerve anatomy from the cranial base to its insertion in the tongue and provide a more detailed explanation of its course to prevent procedural nerve injuries. Fifteen human cadavers from the University of Alabama at Birmingham School of Medicine's Anatomical Donor Program were reviewed. The anatomic structures and landmarks were identified and confirmed by anatomists. Lingual nerve dissection was carried out and reviewed on 15 halved human cadaver skulls (total specimens, 28). Cadaveric dissection provides a detailed examination of the lingual nerve from the cranial base to tongue insertion. The lingual nerve receives the chorda tympani nerve approximately 1 cm below the bifurcation of the lingual and inferior alveolar nerves. The pathway of the lingual nerve is in contact with the periosteum of the mandible just behind the internal oblique ridge. The lingual nerve crosses the submandibular duct at the interproximal space between the mandibular first and second molars. The submandibular ganglion is suspended from the lingual nerve at the distal area of the second mandibular molar. A zoning classification is another way to more accurately describe the lingual nerve based on close anatomic landmarks as seen in human cadaveric specimens. This system could identify particular areas of interest that might be at greater procedural risk. Published by Elsevier Inc.

  20. The current evidence and implications of lingual orthodontics

    Directory of Open Access Journals (Sweden)

    Pratap Saini

    2016-01-01

    Full Text Available The purpose of this review is to investigate the current evidence and implications of lingual orthodontics. The electronic database search was done on PubMed, Cochrane Library, Embase, EBSCOhost, Web of Knowledge, and Google Scholar reporting on appliance design, bonding, and laboratory setup, biomechanics, survey studies, case reports, and treatment outcomes to find the current evidence of lingual orthodontics. The evidence available on lingual orthodontics traces a very clear and predictable pattern. The 80′s was devoted to the limitation and progression of the concept; the 90′s to the comparison between labial and lingual and the evolution of laboratory technique and bracket system. The last decade focuses on innovations, the predictability of outcomes, the impact of white spot lesion, and the patient acceptability. This review also shows that biomechanical principles of lingual orthodontics are well understood and established today, any case that can be treated with labial orthodontic appliance, can also be treated effectively with lingual orthodontic appliance as the completely customized lingual appliance can provide predetermined treatment outcome.

  1. Bolus characteristics based on Magnetic Resonance Angiography

    Directory of Open Access Journals (Sweden)

    Bi Xiaoming

    2006-10-01

    Full Text Available Abstract Background A detailed contrast bolus propagation model is essential for optimizing bolus-chasing Computed Tomography Angiography (CTA. Bolus characteristics were studied using bolus-timing datasets from Magnetic Resonance Angiography (MRA for adaptive controller design and validation. Methods MRA bolus-timing datasets of the aorta in thirty patients were analyzed by a program developed with MATLAB. Bolus characteristics, such as peak position, dispersion and bolus velocity, were studied. The bolus profile was fit to a convolution function, which would serve as a mathematical model of bolus propagation in future controller design. Results The maximum speed of the bolus in the aorta ranged from 5–13 cm/s and the dwell time ranged from 7–13 seconds. Bolus characteristics were well described by the proposed propagation model, which included the exact functional relationships between the parameters and aortic location. Conclusion The convolution function describes bolus dynamics reasonably well and could be used to implement the adaptive controller design.

  2. Lingual Epithelial Stem Cells and Organoid Culture of Them

    Directory of Open Access Journals (Sweden)

    Hiroko Hisha

    2016-01-01

    Full Text Available As tongue cancer is one of the major malignant cancers in the world, understanding the mechanism of maintenance of lingual epithelial tissue, which is known to be the origin of tongue cancer, is unquestionably important. However, the actual stem cells that are responsible for the long-term maintenance of the lingual epithelium have not been identified. Moreover, a simple and convenient culture method for lingual epithelial stem cells has not yet been established. Recently, we have shown that Bmi1-positive cells, residing at the second or third layer of the epithelial cell layer at the base of the interpapillary pit (IPP, were slow-cycling and could supply keratinized epithelial cells for over one year, indicating that Bmi1-positive cells are long-term lingual epithelial stem cells. In addition, we have developed a novel lingual epithelium organoid culture system using a three-dimensional matrix and growth factors. Here, we discuss current progress in the identification of lingual stem cells and future applications of the lingual culture system for studying the regulatory mechanisms of the lingual epithelium and for regenerative medicine.

  3. The lingualized occlusion of complete denture

    Institute of Scientific and Technical Information of China (English)

    BEN Wei-hong; Eleni Roumanas

    2008-01-01

    This article reviews the literatures dealing with the lingualized occlusion of complete denture including the origin,development and research. Lingualized occlusion is a valuable concept because many advantages of anatomic and nonanatomic occlusions are retained,satisfactory occlusion is easily obtained,balanced occlusion can be accomplished.

  4. A comparative assessment of torque generated by lingual and conventional brackets

    NARCIS (Netherlands)

    Sifakakis, I.; Pandis, N.; Makou, M.; Eliades, T.; Katsaros, C.; Bourauel, C.

    2013-01-01

    The aim of this study was to assess the effect of bracket type on the labiopalatal moments generated by lingual and conventional brackets. Incognito lingual brackets (3M Unitek), STb lingual brackets (Light Lingual System; ORMCO), In-Ovation L lingual brackets (DENTSPLY GAC), and conventional 0.018

  5. Lingual Orthodontics simplified : Incognito -customization perfected

    Directory of Open Access Journals (Sweden)

    Haroutioun Dedeyan

    2013-01-01

    Full Text Available Esthetic orthodontics is the need of the hour, fuelled by the increasing number of adult patients seeking orthodontic treatment. Alternatives to labial appliance include clear aligners and lingual appliance. Conventional lingual treatment is laborious in terms of laboratory setup and manual dexterity of the operator, coupled with less than optimum treatment results. Customization of the appliance to meet varied requirements of each patient due to highly variable lingual morphology within and amongst patients is the key to successful treatment in lingual orthodontics. Efforts at bracket base customization using intra-oral jigs and laboratory setups are fraught with unavoidable errors affecting treatment outcome. With the advent of computer-aided design and computer-aided manufacturing (CAD/CAM technology the Eldorado of true customization is now a reality. This paper introduces the Incognito Appliance System based on custom-made brackets and custom-made series of pre-bent wires using state of art CAD/CAM manufacturing procedures.

  6. Targeted Treatment With Radio Frequency Ablation for Lingual Tonsil

    Directory of Open Access Journals (Sweden)

    Suvi Renkonen

    2018-01-01

    Full Text Available Objectives: Benign enlargement of the lingual tonsils due to various causes may cause symptoms that warrant treatment. Conventional lingual tonsillectomy remains a challenging procedure, and there is no established standard procedure. We aimed to review the patients receiving different methods of lingual tonsil surgery for various indications at our institute. Methods: Retrospective clinical data on all patients with an ablative operation of the tongue base during the 8-year period between 2007 and 2014 at the Helsinki University Hospital, Helsinki, Finland, were reviewed. The larger cohort comprised 35 patients, of whom 26 were men (74%. Ten patients had undergone solely lingual tonsil radio frequency ablation (LTRFA. The minimum follow-up time for all patients was 2 years. Results: Of the 10 patients, 5 patients with LTRFA had been operated on because of symptomatic lingual tonsil hypertrophy and 5 because of periodic fever associated with possible lingual tonsil involvement. In 2 of the 5 patients with periodic fever, the fever cycles ended after the operation. Of the 5 patients, 3 patients with symptomatic lingual tonsil hypertrophy have been non-symptomatic after 1 to 3 treatment sessions. The last 2 patients continue to have persistent symptoms. There were no major complications. Conclusions: Development of new approaches for the management of various lingual tonsil conditions is warranted. Lingual tonsil volume reduction by LTRFA seems to be a treatment alternative with low morbidity but with limited curative effect only.

  7. Characterization of an intravenously injected bolus

    International Nuclear Information System (INIS)

    Samuel, A.M.; Raikar, U.R.; Atmaram, S.H.; Ganatra, R.D.

    1976-01-01

    A study of some parameters affecting the time activity histogram of an intravenous bolus injection of radioactivity was performed. A scoring system for bolus compactness was attempted. A score of 2 and above was considered to be a satisfactory bolus. Volumes less than 1 ml tended to result in a satisfactory bolus. The nature of radiopharmaceutical injected, different injecters and age of the patient did not affect the score. Thyrotoxic patients gave the best bolus score. (orig.) [de

  8. Applied anatomy of the lingual nerve: relevance to dental anaesthesia.

    Science.gov (United States)

    Tan, Vui Leng; Andrawos, Alice; Ghabriel, Mounir N; Townsend, Grant C

    2014-03-01

    (1) to classify the external morphology of the lingual nerve and investigate any relationship between its external and internal morphology, (2) to explore the fascicular structure, nerve tissue density and capillary density of the lingual nerve, and (3) to provide an anatomical explanation as to why adverse clinical outcomes more commonly affect the lingual nerve following local dental anaesthesia. Where possible, comparisons were made between the lingual and inferior alveolar nerves. The lingual and inferior alveolar nerves were examined in 23 hemi-sectioned heads macroscopically and microscopically 2mm above the lingula. The lingual nerve was also examined in the regions of the third and second molars. Specimens underwent histological processing and staining with Haematoxylin & Eosin, Masson's Trichrome, anti-GLUT-1 and anti-CD 34. The lingual nerve became flatter as it traversed through the pterygomandibular space. There was an increase in the connective tissue and a decrease in nerve tissue density along the lingual nerve (p<0.001). At 2mm above the lingula, the lingual nerve was uni-fascicular in 39% of cases, whilst the inferior alveolar nerve consistently had more fascicles (p<0.001). The lingual nerve fascicles had thicker perineurium but the endoneurial vascular density was not significantly different in the two nerves. The greater susceptibility of lingual nerve dysfunction during inferior alveolar nerve blocks may be due to its uni-fascicular structure and the thicker perineurium, leading to increased endoneurial pressure and involvement of all axons if oedema or haemorrhage occurs due to trauma. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. Esophageal contractions, bolus transit and perception of transit after swallows of liquid and solid boluses in normal subjects

    Directory of Open Access Journals (Sweden)

    Juciléia Dalmazo

    2012-12-01

    Full Text Available CONTEXT: Esophageal dysphagia is the sensation that the ingested material has a slow transit or blockage in its normal passage to the stomach. It is not always associated with motility or transit alterations. OBJECTIVES: To evaluate in normal volunteers the possibility of perception of bolus transit through the esophagus after swallows of liquid and solid boluses, the differences in esophageal contraction and transit with these boluses, and the association of transit perception with alteration of esophageal contraction and/or transit. METHODS: The investigation included 11 asymptomatic volunteers, 4 men and 7 women aged 19-58 years. The subjects were evaluated in the sitting position. They performed swallows of the same volume of liquid (isotonic drink and solid (macaroni boluses in a random order and in duplicate. After each swallow they were asked about the sensation of bolus passage through the esophagus. Contractions and transit were evaluated simultaneously by solid state manometry and impedance. RESULTS: Perception of bolus transit occurred only with the solid bolus. The amplitude and area under the curve of contractions were higher with swallows of the solid bolus than with swallows of the liquid bolus. The difference was more evident in swallows with no perception of transit (n = 12 than in swallows with perception (n = 10. The total bolus transit time was longer for the solid bolus than for the liquid bolus only with swallows followed by no perception of transit. CONCLUSION: The results suggest that the perception of esophageal transit may be the consequence of inadequate adaptation of esophageal transit and contraction to the characteristics of the swallowed bolus.

  10. Lingual nerve injury following surgical removal of mandibular third molar

    Directory of Open Access Journals (Sweden)

    Abduljaleel Azad Samad

    2017-12-01

    Full Text Available Background and objective: The close proximity of lingual nerve in relation to the lingual cortical bone of the posterior mandibular third molar is clinically important because lingual nerve may be subjected to trauma during surgical removal of the impacted lower third molar. This prospective study aimed to evaluate the incidence of lingual nerve paresthesia following surgical removal of mandibular third molar in College of Dentistry, Hawler Medical University. Methods: A total of 116 third molars surgery were carried out under local anesthesia for 116 patients for removal of lower mandibular teeth Using Terence Ward's incision made in all cases, and after that, the buccal flap was reflected, lingual tissues had been retracted during bone removal with a periosteal elevator. The sensory disturbance was evaluated on the 7th postoperative day by standard questioning the patients: “Do you have any unusual feeling in your tongue, lingual gingiva and mucosa of the floor of the mouth?" Results: One patient experienced sensory disturbance, the lingual nerve paresthesia incidence was 0.9% as a transient sensory disturbance, while no patient of permanent sensory disturbance. Conclusion: The incidence of injury to the lingual nerve can be minimized by careful clinical evaluation, surgeon’s experience, surgical approach and knowledge about anatomical landmarks during surgical removal of an impacted lower third molar tooth.

  11. Survey on the practice of lingual orthodontics in India

    Directory of Open Access Journals (Sweden)

    Sourabh Agrawal

    2016-01-01

    Full Text Available Aim: Lingual orthodontics provides an esthetic option of orthodontic treatment, especially for the adults. Lingual orthodontics being an important treatment modality requires extensive training and expertise for honest outcomes. In this study, we have composed a questionnaire to obtain the trend in the practice of lingual orthodontics in India. Materials and Methods: A questionnaire was composed of several aspects of lingual orthodontics. The survey instrument was hosted electronically on a secure website, www.typeform.com . The survey was optimized for presentation on tablets, mobiles, and laptops, which were the platforms used by participants to take the survey. The survey data were received and saved by the same secure website. Pearson Chi-square test was done using SPSS 17.0 version software to determine the correlation between treatment outcome and the use of laboratory for the initial setup. Results: A total of 248 orthodontists responded to the survey, 70% orthodontists said that they practice lingual orthodontics. Among the orthodontists who practice lingual orthodontics, 71% orthodontists treat extraction and nonextraction cases and 29% treat only nonextraction cases. Forty percent orthodontists said their final finishing of case is good, 16% said that final finishing is average, 26.5% said that final finishing is very good, and only 17.5% said that it is excellent. Statistically significant correlation exists (P = 0.004 between the treatment outcome and use of laboratory for initial setup. Conclusion: Many orthodontists are taking up lingual cases in India. Survey indicates that there is still room for betterment in terms of the final treatment outcome, and many orthodontists feel that there is need of formal training for expertise in lingual orthodontics.

  12. Transoral videolaryngoscopic surgery for papillary carcinoma arising in lingual thyroid.

    Science.gov (United States)

    Mogi, Chisato; Shinomiya, Hirotaka; Fujii, Natsumi; Tsuruta, Tomoyuki; Morita, Naruhiko; Furukawa, Tatsuya; Teshima, Masanori; Kanzawa, Maki; Hirokawa, Mitsuyoshi; Otsuki, Naoki; Nibu, Ken-Ichi

    2018-05-15

    Carcinoma arising in lingual thyroid is an extremely rare entity accounting for only 1% of all reported ectopic thyroids. Here, we report a case of carcinoma arising in lingual thyroid, which has been successfully managed by transoral resection and bilateral neck dissections. A lingual mass 4-cm in diameter with calcification was incidentally detected by computed tomography at medical check-up. No thyroid tissue was observed in normal position. Ultrasound examination showed bilateral multiple lymphadenopathies. Fine needle aspiration biopsy from lymph node in his right neck was diagnosed as Class III and thyroglobulin level of the specimen was 459ng/ml. Due to the difficulty in performing FNA of the lingual masses, right neck dissection was performed in advance for diagnostic purpose. Pathological examination showed existence of large and small follicular thyroid tissues in several lymph nodes, suggesting lymph node metastasis from thyroid carcinoma. Two months after the initial surgery, video-assisted transoral resection of lingual thyroid with simultaneous left neck dissection was performed. Postoperative course was uneventful. Papillary carcinoma was found in the lingual thyroid and thyroid tissues were also found in left cervical lymph nodes. Video-assisted transoral resection was useful for the treatment of thyroid cancer arising in lingual thyroid. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Bolus use in radiotherapy

    Directory of Open Access Journals (Sweden)

    Sérgio Spezzia

    2017-01-01

    Full Text Available Preliminary to the radiation therapy, it is posisble to develop a therapeutic device contained in the buccomaxillofacial prosthesis resources, creating the bolus. Bolus are materials used to increase the dose on the entrance surface of a field or to compensate for a lack of tissue. The requirements for a material to be used as a bolus include to interact with ionizing radiations in a similar manner to tissues and to be soft enough to allow its molding to the patient’s contour. There are various materials available for this purpose, however, with a relatively high cost. Some inexpensive options can also be used, such as pressed cellophane and wet gauze, however, these materials do not present favorable malleability and do not offer true reproducibility. The aim of this article was to ascertain whether there is harmonious knowledge of this technique by dental surgeons, medical oncologists and radiotherapists. This technique or device minimizes the deleterious effects resulting from exposure to radiation. It was concluded the bolus can reduce possible complications arising from radiation therapy, concomitantly offering improved living conditions during treatment.

  14. The features of scientist’s lingual identity as representative of Russian cosmism discourse

    Directory of Open Access Journals (Sweden)

    Anita B. Tikhonova

    2010-12-01

    Full Text Available This article contains information about the lingual identity of the representative of the Russian cosmism. The analysis of the three levels of the structure of lingual identity is making: verbal and semantic level, lingual and cognitive level, motivational levels of lingual identity.

  15. Microimplant in Lingual Tori to Correct Anterior Crossbite in Adult

    Directory of Open Access Journals (Sweden)

    Deepak Rai

    2012-01-01

    Full Text Available Anterior crossbites are difficult to correct in adults. A case where microimplants were placed in the lingual tori of an adult patient along with a lingual appliance is reported. The use of the esthetic lingual appliance along with the stable anchorage provided by the microimplants, aids in decreasing the duration of treatment as well as making the same more acceptable to the patient.

  16. Bolus injections of measured amounts of radioactivity

    International Nuclear Information System (INIS)

    Wesolowski, C.A.; Hogendoorn, P.; Vandierendonck, R.; Driedger, A.A.

    1988-01-01

    Many time-based radionuclide techniques, such as glomerular filtration rate measurement (GFR), require prompt intravenous delivery of and accurately measured tracer bolus with minimal residual tracer retention at the injection site. The quality assurance aspects of two antecubital vein, quantitative injection techniques were investigated. A flush bolus technique using a tuberculin syringe piggybacked onto a 10-ml saline flush was compared to a single blood pressure cuff injection technique. Scintillation camera data for each technique were compared for bolus duration in the abdominal aorta and for residual activity at the injection site at 5 min. Bolus times were measured as the FWHM of the gamma variate fit to the abdominal aortic regional time-activity curves. Relatively little focal activity was seen in the antecubital injection site following the flush bolus: marked residual activity was seen following the blood pressure cuff injections. The injection site/arm background ratios averaged 1.3 for the flush bolus and 30.1 for the cuff technique. Although both methods allowed accurate in vitro determination of administered radioactivity, only the tuberculin syringe flush bolus technique was acceptable for time-based quantitation because of its superior in vivo characteristics

  17. Extraction mechanics in lingual orthodontics: Challenges and solutions

    Directory of Open Access Journals (Sweden)

    Tushar M Hegde

    2016-01-01

    Full Text Available The 21st century has witnessed a slow but sure incorporation of lingual orthodontic protocols into the orthodontic mainstream. Extraction mechanics with lingual orthodontic appliance poses challenges to even the most experienced clinician. This article is a case series of three cases treated by extraction mechanics in a detailed and sequential manner.

  18. Morphology of the lingual papillae in the fishing cat.

    Science.gov (United States)

    Emura, Shoichi; Okumura, Toshihiko; Chen, Huayue

    2014-01-01

    We examined the dorsal lingual surface of an adult fishing cat (Prionailurus viverrinus) by scanning electron microscopy. The filiform papillae on the lingual apex had several pointed processes. The connective tissue core of the filiform papillae resembleda a well in shape. The filiform papillae on the anterior part of the lingual body were large and cylindrical in shape. The connective tissue core of the filiform papillae consisted of a large conical papilla. The filiform papillae on the central part of the lingual body were large and conical. The connective tissue core of the filiform papillae consisted of a large main process and some secondary processes. The connective tissue core of the fungiform papillae did not have processes. The vallate papillae were surrounded by a groove and a pad. The top of the connective tissue core of the vallate papillae had a rough surface with no spines.

  19. Piezosurgery for the lingual split technique in mandibular third molar removal: a suggestion.

    Science.gov (United States)

    Pippi, Roberto; Alvaro, Roberto

    2013-03-01

    The lingual split technique is a surgical procedure for extraction of impacted mandibular third molar throughout a lingual approach. The main disadvantage of this technique is the high rate of temporary lingual nerve injury mainly because of the trauma induced by the lingual flap retraction. The purpose of this paper is to suggest the use of piezosurgery in performing the lingual cortical plate osteotomy of the third molar alveolar process. Surgical procedure was performed under general anesthesia, and it lasted approximately 60 minutes. After the buccal and lingual full-thickness flaps were incised and elevated, a piezosurgical device was used for osteotomy. A well-defined bony window was then removed, and it allowed the entire tooth was extracted in a lingual direction. The patient did not show any neurological postoperative complication. Lingual and inferior alveolar nerve functionality was normal before as well as after surgery. The use of piezoelectric surgery seems to be a good option in removing lower third molars when a lingual access is clearly indicated. The only disadvantage of this technique can be represented by an operating time lengthening possibly because of a lower power cut of the piezoelectric device, to the high mineralization of the mandibular cortical bone and to the use of inserts with a low degree of sharpening.

  20. Clinical and microbiologic effects of lingual cervical coverage by removable partial dentures.

    Science.gov (United States)

    Ao, Aiichiro; Wakabayashi, Noriyuki; Nitta, Hiroshi; Igarashi, Yoshimasa

    2013-01-01

    The effect of gingival coverage by removable partial dentures (RPDs) on bacterial accumulation has not been sufficiently established. The aim of this study was to evaluate the periodontal and microbiologic reactions to mandibular major connectors. It was hypothesized that the use of a lingual plate increases the risk of periodontal disease. Fourteen subjects (mean age: 69.0 years) received oral hygiene instructions and ultrasonic debridement prior to examination. Each subject received an experimental RPD incorporating either a lingual bar or lingual plate for the first 8 weeks and was then switched to the other option for the next 8 weeks. Clinical parameters (Plaque Index, Gingival Index, probing depth, and tooth mobility) were recorded. Subgingival plaque samples were collected from the periodontal pocket in the test site to measure the colonization of periodontal pathogens after the use of each denture. The mean probing depth was significantly greater after use of the lingual plate compared to the lingual bar (P bacterial species showed smaller numbers of microorganisms at the second examination than at the first. The lingual cervical coverage did not precipitate the accumulation of anaerobic microorganisms, although it could potentially induce gingival inflammation. The results suggest that a lingual plate can be used as safely as a lingual bar if oral and denture hygiene are carefully monitored.

  1. Tranexamic Acid in Bolus Alone Vs Bolus and Continuous Infusion in Hip Arthroscopy

    OpenAIRE

    Fatih Karaaslan; Roberto Seijas; Andrea Sallent; Oscar Ares; Wenceslao Espinosa; Pedro Alvarez; Ramón Cugat; Patricia Lopez

    2017-01-01

    AIM: the present study examines the effects of tranexamic acid (TXA) on reducing blood loss during hip arthroscopy, comparing two different methods of administration (bolus vs infusion). METHODS: a prospective study with 70 patients undergoing hip arthroscopy was carried out. The patients within the TXA infusion group (group A) received TXA an 2-g intravenous bolus 30 min before skin incision intravenously followed by 10 mg/kg/h infusion (continued during the entire surgery)...

  2. Comparison and evaluation between 3D-bolus and step-bolus, the assistive radiotherapy devices for the patients who had undergone modified radical mastectomy surgery

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Won Seok; Park, Kwang Woo; Shin, Dong Bong; Kim, Jong Dae; Kim, Sei Joon; Ha, Jin Sook; Jeon, Mi Jin; Cho, Yoojin; Jung, Inho [Dept. of Radiation Oncology, Gangnam Severance Hospital, Seoul, (Korea, Republic of)

    2016-06-15

    This study aimed to compare and evaluate between the efficiency of two respective devices, 3D-bolus and step-bolus when the devices were used for the treatment of patients whose chest walls were required to undergo the electron beam therapy after the surgical procedure of modified radical mastectomy, MRM. The treatment plan of reverse hockey stick method, using the photon beam and electron beam, had been set for six breast cancer patients and these 6 breast cancer patients were selected to be the subjects for this study. The prescribed dose of electron beam for anterior chest wall was set to be 180 cGy per treatment and both the 3D-bolus, produced using 3D printer(CubeX, 3D systems, USA) and the self-made conventional step-bolus were used respectively. The surface dose under 3D-bolus and step-bolus was measured at 5 measurement spots of iso-center, lateral, medial, superior and inferior point, using GAFCHROMIC EBT3 film (International specialty products, USA) and the measured value of dose at 5 spots was compared and analyzed. Also the respective treatment plan was devised, considering the adoption of 3D-bolus and stepbolus and the separate treatment results were compared to each other. The average surface dose was 179.17 cGy when the device of 3D-bolus was adopted and 172.02 cGy when step-bolus was adopted. The average error rate against the prescribed dose of 180 cGy was -(minus) 0.47% when the device of 3D-bolus was adopted and it was -(minus) 4.43% when step-bolus was adopted. It was turned out that the maximum error rate at the point of iso-center was 2.69%, in case of 3D-bolus adoption and it was 5,54% in case of step-bolus adoption. The maximum discrepancy in terms of treatment accuracy was revealed to be about 6% when step-bolus was adopted and to be about 3% when 3D-bolus was adopted. The difference in average target dose on chest wall between 3D-bolus treatment plan and step-bolus treatment plan was shown to be insignificant as the difference was only 0

  3. Comparison and evaluation between 3D-bolus and step-bolus, the assistive radiotherapy devices for the patients who had undergone modified radical mastectomy surgery

    International Nuclear Information System (INIS)

    Jang, Won Seok; Park, Kwang Woo; Shin, Dong Bong; Kim, Jong Dae; Kim, Sei Joon; Ha, Jin Sook; Jeon, Mi Jin; Cho, Yoojin; Jung, Inho

    2016-01-01

    This study aimed to compare and evaluate between the efficiency of two respective devices, 3D-bolus and step-bolus when the devices were used for the treatment of patients whose chest walls were required to undergo the electron beam therapy after the surgical procedure of modified radical mastectomy, MRM. The treatment plan of reverse hockey stick method, using the photon beam and electron beam, had been set for six breast cancer patients and these 6 breast cancer patients were selected to be the subjects for this study. The prescribed dose of electron beam for anterior chest wall was set to be 180 cGy per treatment and both the 3D-bolus, produced using 3D printer(CubeX, 3D systems, USA) and the self-made conventional step-bolus were used respectively. The surface dose under 3D-bolus and step-bolus was measured at 5 measurement spots of iso-center, lateral, medial, superior and inferior point, using GAFCHROMIC EBT3 film (International specialty products, USA) and the measured value of dose at 5 spots was compared and analyzed. Also the respective treatment plan was devised, considering the adoption of 3D-bolus and stepbolus and the separate treatment results were compared to each other. The average surface dose was 179.17 cGy when the device of 3D-bolus was adopted and 172.02 cGy when step-bolus was adopted. The average error rate against the prescribed dose of 180 cGy was -(minus) 0.47% when the device of 3D-bolus was adopted and it was -(minus) 4.43% when step-bolus was adopted. It was turned out that the maximum error rate at the point of iso-center was 2.69%, in case of 3D-bolus adoption and it was 5,54% in case of step-bolus adoption. The maximum discrepancy in terms of treatment accuracy was revealed to be about 6% when step-bolus was adopted and to be about 3% when 3D-bolus was adopted. The difference in average target dose on chest wall between 3D-bolus treatment plan and step-bolus treatment plan was shown to be insignificant as the difference was only 0

  4. A study on developing customized bolus using 3D prints

    International Nuclear Information System (INIS)

    Jung, Sang Min; Yang, Jin Ho; Lee, Seung Hyun; Kim, Jin Uk; Yeom, Du Seok

    2015-01-01

    3D Printers are used to create three-dimensional models based on blueprints. Based on this characteristic, it is feasible to develop a bolus that can minimize the air gap between skin and bolus in radiotherapy. This study aims to compare and analyze air gap and target dose at the branded 1 cm bolus with the developed customized bolus using 3D printers. RANDO phantom with a protruded tumor was used to procure images using CT simulator. CT DICOM file was transferred into the STL file, equivalent to 3D printers. Using this, customized bolus molding box (maintaining the 1 cm width) was created by processing 3D printers, and paraffin was melted to develop the customized bolus. The air gap of customized bolus and the branded 1 cm bolus was checked, and the differences in air gap was used to compare D max , D min , D mean , D 95% and V 95% in treatment plan through Eclipse. Customized bolus production period took about 3 days. The total volume of air gap was average 3.9 cm 3 at the customized bolus. And it was average 29.6cm 3 at the branded 1 cm bolus. The customized bolus developed by the 3D printer was more useful in minimizing the air gap than the branded 1 cm bolus. In the 6 MV photon, at the customized bolus, D max , D min , D mean , D 95% , V 95% of GTV were 102.8%, 88.1%, 99.1%, 95.0%, 94.4% and the D max , D min , D mean , D 95% , V 95% of branded 1 cm bolus were 101.4%, 92.0%, 98.2%, 95.2%, 95.7%, respectively. In the proton, at the customized bolus, D max , D min , D mean , D 95% , V 95% of GTV were 104.1%, 84.0%, 101.2%, 95.1%, 99.8% and the D max , D min , D mean , D 95% , V 95% of branded 1cm bolus were 104.8%, 87.9%, 101.5%, 94.9%, 99.9%, respectively. Thus, in treatment plan, there was no significant difference between the customized bolus and 1 cm bolus. However, the normal tissue nearby the GTV showed relatively lower radiation dose. The customized bolus developed by 3D printers was effective in minimizing the air gap, especially when it is used against

  5. Lingual structural pattern of juvenile Chameleon, Chameleo chameleon

    Directory of Open Access Journals (Sweden)

    Ahmed A. El Mansi

    2017-06-01

    Full Text Available It is belong to the order Squamata, family, Chamaeleonidae. They have characteristic features of tongue protrusion during capturing prey attracts many research works and assay its velocity during protrusion. Yet little studies touched the anatomical and histological feature of the juvenile tongue and especially the middle tongue region involved in the tongue elongation, the present study aimed to focus on the histological structure of the mid-tongue and clarify its role in projection of the tongue as well as the glandular structure, keratinization of lingual epithelium and proliferation capacity of the fore-tongue region in relation with their feeding habits during the juvenile age. Juvenile Chameleo chameleon are collected from Abu Rawash, north of Giza Governorate, Egypt during summer 2015. Three juvenile developmental stages are used in the present study and categorized according to the gross morphological criteria of head, abdomen and limb lengths. The tongue and hyoid apparatus were removed and photographed. Histological, immunohistochemistry of cytokeratin and stem cell factor and scanning electronic microscopic investigations were carried out on the fore-tongue region, meanwhile only histological studies were done for the median tongue region. Morphometric assessments of number and length of lingual papillae and grades of cytokeratin and stem cell expression were done. Histologically, the dorsal lingual mucosa of the fore-tongue possessed different pattern of lingual papillae including finger-like, club, cubical, biforked and multi-branched papillae. The finger-like papillae are more abundant compared to the other types. The lamina propria of anterior median tongue pad are more glandular and exhibited abundant distribution of PAS-positive tubular glands and moderate alcian blue staining affinity of both alveolar and branched alveolar glands. There is no detected keratinization of the lingual epithelium. Stem cell factor appeared denser on

  6. A study on developing customized bolus using 3D prints

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Sang Min; Yang, Jin Ho; Lee, Seung Hyun; Kim, Jin Uk; Yeom, Du Seok [Dept. of Proton Therapy Center, National Cancer Center, Ilsan (Korea, Republic of)

    2015-06-15

    3D Printers are used to create three-dimensional models based on blueprints. Based on this characteristic, it is feasible to develop a bolus that can minimize the air gap between skin and bolus in radiotherapy. This study aims to compare and analyze air gap and target dose at the branded 1 cm bolus with the developed customized bolus using 3D printers. RANDO phantom with a protruded tumor was used to procure images using CT simulator. CT DICOM file was transferred into the STL file, equivalent to 3D printers. Using this, customized bolus molding box (maintaining the 1 cm width) was created by processing 3D printers, and paraffin was melted to develop the customized bolus. The air gap of customized bolus and the branded 1 cm bolus was checked, and the differences in air gap was used to compare D{sub max}, D{sub min}, D{sub mean}, D{sub 95%} and V{sub 95%} in treatment plan through Eclipse. Customized bolus production period took about 3 days. The total volume of air gap was average 3.9 cm{sup 3} at the customized bolus. And it was average 29.6cm{sup 3} at the branded 1 cm bolus. The customized bolus developed by the 3D printer was more useful in minimizing the air gap than the branded 1 cm bolus. In the 6 MV photon, at the customized bolus, D{sub max}, D{sub min}, D{sub mean}, D{sub 95%}, V{sub 95%} of GTV were 102.8%, 88.1%, 99.1%, 95.0%, 94.4% and the D{sub max}, D{sub min}, D{sub mean}, D{sub 95%}, V{sub 95%} of branded 1 cm bolus were 101.4%, 92.0%, 98.2%, 95.2%, 95.7%, respectively. In the proton, at the customized bolus, D{sub max}, D{sub min}, D{sub mean}, D{sub 95%}, V{sub 95%} of GTV were 104.1%, 84.0%, 101.2%, 95.1%, 99.8% and the D{sub max}, D{sub min}, D{sub mean}, D{sub 95%}, V{sub 95%} of branded 1cm bolus were 104.8%, 87.9%, 101.5%, 94.9%, 99.9%, respectively. Thus, in treatment plan, there was no significant difference between the customized bolus and 1 cm bolus. However, the normal tissue nearby the GTV showed relatively lower radiation dose. The

  7. Intravenous contrast medium administration at 128 multidetector row CT pulmonary angiography: Bolus tracking versus test bolus and the implications for diagnostic quality and effective dose

    International Nuclear Information System (INIS)

    Rodrigues, J.C.L.; Mathias, H.; Negus, I.S.; Manghat, N.E.; Hamilton, M.C.K.

    2012-01-01

    Aim: To investigate the effects of a test bolus protocol contrast medium administration on diagnostic image quality in computed tomography pulmonary angiography (CTPA). Materials and methods: Fifty patients referred for exclusion of pulmonary embolism underwent CTPA using a test bolus protocol CTPA at 120 kVp and were compared with 50 patients undergoing CTPA using a standard bolus-tracking protocol at 120 kVp, via assessment of attenuation, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) seen in the pulmonary arteries (PAs). An additional group of 10 non-obese patients who underwent CTPA using a test bolus protocol performed at 100 kVp were also analysed. Mean effective dose was calculated from the dose–length product, using standard conversion factors. Results: The test bolus protocol showed significantly higher attenuation, SNR, and CNR in the pulmonary vasculature down to the segmental level compared to bolus-tracking CTPA (p < 0.0001). There was no significant difference in effective dose between the test bolus and bolus tracking cohorts. The additional group of test bolus CTPA examinations performed at 100 kVp had a significantly reduced effective dose in comparison to both test bolus CTPA at 120 kVp and bolus-tracking CTPA at 120 kVp (p < 0.005) yet maintained mean PA attenuation to segmental level significantly better than bolus-tracking CTPA performed at 120 kVp and comparable to the test bolus cohort performed at 120 kVp. Conclusion: Test bolus contrast administration should be used as an optimal protocol. Performing test bolus CTPA at 100 kVp, as opposed to 120 kVp, significantly reduces dose without compromising PA attenuation in non-obese subjects.

  8. Pharyngeal Pressure and Timing During Bolus Transit

    Science.gov (United States)

    Walczak, Chelsea C.; Jones, Corinne A.; McCulloch, Timothy M.

    2018-01-01

    Determining intrabolus pressure (IBP) at the upper esophageal sphincter (UES) and in the esophagus has given compelling evidence that IBP can be a predictor for swallowing dysfunction. Studies have looked most superiorly at the low hypopharynx region but there has been no inquiry into what IBP measures throughout the entire pharynx can tell us. We present a study to describe the pressures within and surrounding the moving bolus throughout the pharynx and into the UES. Simultaneous HRM and videofluoroscopy were performed in 10 healthy subjects swallowing ten 10 mL thin-liquid barium boluses. Three events surrounding bolus movement were tracked via videofluoroscopy, two additional events were found using manometric measures. As the bolus passes through the pharynx, low pressure is created at and below the head of the bolus. A modest pressure increase is seen as the bolus passes through the pharynx and finally, high pressure is observed at the bolus tail, followed by an even larger pressure generation of a clearance event. HRM allows for greater resolution in data collection in the pharynx and in this study, aided in identifying semi unique characteristics around the hypopharynx and the UES which are consistent with the complex anatomy of the regions and the transition of the UES from active closure to relaxed opening. In the future, additional studies designed to look at aged and diseased populations may lead to better understanding of disease etiology, and treatment options. PMID:27565155

  9. Lingual cysticercosis

    Directory of Open Access Journals (Sweden)

    A P Pichare

    2014-01-01

    Full Text Available Cysticercosis is a disease caused by larval form of tapeworm. Cysticercus cellulose primarily develops in tissues of pigs. Infection of human tissues is unusual and affliction of the oral cavity is rare. We, herein, present a case of lingual cysticercosis without involvement of any other site. A 5-year-old male, non-vegetarian child presented with a painless, pearly white, solitary nodular swelling on posterior dorsal side of tongue since 3 months. Excision biopsy was done. Histopathology revealed cysticercous cellulose in tongue muscles.

  10. Isolated lingual involvement in Wilson′s disease

    Directory of Open Access Journals (Sweden)

    Neera Choudhary

    2015-01-01

    Full Text Available Lingual involvement can occur in a variety of neurological disorders including pyramidal, extrapyramidal and lower motor neuron disorders. It can be seen in the form of tremor, bradykinesia, dystonia, atrophy and weakness of tongue movements and can clinically present as difficulty in swallowing and dysarthria which can be a source of great discomfort to the patient. We describe a patient who presented with isolated lingual involvement and was diagnosed to have Wilsons′s disease. This case emphasizes the clinical variability in presentation of Wilson′s disease and importance of early clinical diagnosis.

  11. Russian Perceptions of U.S. Lawyers as a Lingual-Cultural Type

    Directory of Open Access Journals (Sweden)

    Evgenia Gulyaeva

    2008-01-01

    Full Text Available This article introduces the reader to the theory of a lingual-cultural personality and lingual-cultural types in particular. A lingual-cultural type is a generalized image of personalities whose behavior and values significantly influ-ence the culture in general and is a representative of ethnic and social variety of the society. The type of an American Lawyer is being analyzed, because in the United States of America, unlike any other country, the role of a lawyer has a pervasive shared understanding. The author examines how lawyers are repre-sented in US popular culture, specifically exploring presentations in legal and crime fiction. She also analyzes results from a survey of 100 Russian students, exploring their perceptions of the lingual-cultural type of US lawyers

  12. Lingual rhetoric paradigm as integrative research prism in philological science

    Directory of Open Access Journals (Sweden)

    Аlexandra A. Vorozhbitova

    2010-12-01

    Full Text Available The article characterizes the lingual rhetoric paradigm as an integrative approach in philology based on three crossing categorical ranges: 1 the ideological aspects of a speech act (ethos, logos, pathos; 2 the phases of the universal ideospeech cycle «from a thought to a word» (invention, disposition (arrangement, elocution (style as the technology of discourse process; 3 the structural levels of a lingual identity (associative verbal network, thesaurus, pragmaticon as the producer of discourse, the carrier of ideology. Hence there are three groups of lingual rhetoric parameters: ethos motivational dispositive, logos thesaurus inventive, pathos verbal elocutive.

  13. Practice Change From Intermittent Medication Boluses to Bolusing From a Continuous Infusion in Pediatric Critical Care: A Quality Improvement Project.

    Science.gov (United States)

    Hochstetler, Jessica L; Thompson, A Jill; Ball, Natalie M; Evans, Melissa C; Frame, Shaun C; Haney, A Lauren; Little, Amelia K; O'Donnell, Jaime L; Rickett, Bryna M; Mack, Elizabeth H

    2018-04-12

    To determine whether implementing a guideline to bolus medications from continuous infusions in PICUs affects nursing satisfaction, patient safety, central line entries, medication utilization, or cost. This is a pre- and postimplementation quality improvement study. An 11-bed ICU and 14-bed cardiac ICU in a university-affiliated children's hospital. Patients less than 18 years old admitted to the PICU or pediatric cardiac ICU receiving a continuous infusion of dexmedetomidine, midazolam, fentanyl, morphine, vecuronium, or cisatracurium from May 2015 to May 2016, excluding November 2015 (washout period), were eligible for inclusion. Change in practice from administering bolus doses from an automated dispensing machine to administering bolus medications from continuous infusion in PICUs. Timing studies were conducted pre- and post implementation in 29 and 26 occurrences, respectively. The median time from the decision to give a bolus until it began infusing decreased by 169 seconds (p 0.05). Annualized cost avoidance was $124,160. Implementation of bolus medications from continuous infusion in PICUs significantly decreased time to begin a bolus dose and increased nursing satisfaction. The practice change also improved medication utilization without negatively impacting patient safety.

  14. Technology for bolus verification in proton therapy

    Science.gov (United States)

    Shipulin, K. N.; Mytsin, G. V.; Agapov, A. V.

    2015-01-01

    To ensure the conformal depth-dose distribution of a proton beam within a target volume, complex shaped range shifters (so-called boluses), which account for the heterogeneous structure of patient tissue and organs in the beam path, were calculated and manufactured. The precise manufacturing of proton compensators used for patient treatment is a vital step in quality assurance in proton therapy. In this work a software-hardware complex that verifies the quality and precision of bolus manufacturing at the Medico-Technical Complex (MTC) was developed. The boluses consisted of a positioning system with two photoelectric biosensors. We evaluated 20 boluses used in proton therapy of five patients. A total number of 2562 experimental points were measured, of which only two points had values that differed from the calculated value by more than 0.5 mm. The other data points displayed a deviation within ±0.5 mm from the calculated value. The technology for bolus verification developed in this work can be used for the high precision testing of geometrical parameters of proton compensators in radiotherapy.

  15. A Systematic Review of Isometric Lingual Strength-Training Programs in Adults With and Without Dysphagia.

    Science.gov (United States)

    McKenna, Victoria S; Zhang, Bin; Haines, Morgan B; Kelchner, Lisa N

    2017-05-17

    This systematic review summarizes the effects of isometric lingual strength training on lingual strength and swallow function in adult populations. Furthermore, it evaluates the designs of the reviewed studies and identifies areas of future research in isometric lingual strength training for dysphagia remediation. A comprehensive literature search of 3 databases and additional backward citation search identified 10 studies for inclusion in the review. The review reports and discusses the isometric-exercise intervention protocols, pre- and postintervention lingual-pressure data (maximum peak pressures and lingual-palatal pressures during swallowing), and oropharyngeal swallowing measures such as penetration-aspiration scales, oropharyngeal residue and duration, lingual volumes, and quality-of-life assessments. Studies reported gains in maximum peak lingual pressures following isometric lingual strength training for both healthy adults and select groups of individuals with dysphagia. However, due to the variability in study designs, it remains unclear whether strength gains generalize to swallow function. Although isometric lingual strength training is a promising intervention for oropharyngeal dysphagia, the current literature is too variable to confidently report specific therapeutic benefits. Future investigations should target homogenous patient populations and use randomized controlled trials to determine the efficacy of this treatment for individuals with dysphagia.

  16. Estimation of Cross-Lingual News Similarities Using Text-Mining Methods

    Directory of Open Access Journals (Sweden)

    Zhouhao Wang

    2018-01-01

    Full Text Available In this research, two estimation algorithms for extracting cross-lingual news pairs based on machine learning from financial news articles have been proposed. Every second, innumerable text data, including all kinds news, reports, messages, reviews, comments, and tweets are generated on the Internet, and these are written not only in English but also in other languages such as Chinese, Japanese, French, etc. By taking advantage of multi-lingual text resources provided by Thomson Reuters News, we developed two estimation algorithms for extracting cross-lingual news pairs from multilingual text resources. In our first method, we propose a novel structure that uses the word information and the machine learning method effectively in this task. Simultaneously, we developed a bidirectional Long Short-Term Memory (LSTM based method to calculate cross-lingual semantic text similarity for long text and short text, respectively. Thus, when an important news article is published, users can read similar news articles that are written in their native language using our method.

  17. Thyroid cancer in lingual thyroid and thyroglossal duct cyst.

    Science.gov (United States)

    Sturniolo, Giacomo; Vermiglio, Francesco; Moleti, Mariacarla

    2017-01-01

    Ectopy is the most common embryogenetic defect of the thyroid gland, representing between 48 and 61% of all thyroid dysgeneses. Persistence of thyroid tissue in the context of a thyroglossal duct remnant and lingual thyroid tissue are the most common defects. Although most cases of ectopic thyroid are asymptomatic, any disease affecting the thyroid may potentially involve the ectopic tissue, including malignancies. The prevalence of differentiated thyroid carcinoma in lingual thyroid and thyroglossal duct cyst is around 1% of patients affected with the above thyroid ectopies. We here review the current literature concerning primary thyroid carcinomas originating from thyroid tissue on thyroglossal duct cysts and lingual thyroid. Copyright © 2016 SEEN. Publicado por Elsevier España, S.L.U. All rights reserved.

  18. A comparative assessment of forces and moments generated by lingual and conventional brackets

    NARCIS (Netherlands)

    Sifakakis, I.; Pandis, N.; Makou, M.; Katsaros, C.; Eliades, T.; Bourauel, C.

    2013-01-01

    The aim of this study was to assess the effect of bracket type on the labiopalatal forces and moments generated in the sagittal plane. Incognito lingual brackets (3M Unitek), STb lingual brackets (Light Lingual System; ORMCO), and conventional 0.018 inch slot brackets (Gemini; 3M Unitek) were bonded

  19. Mandibular lingual vascular canals (MLVC): Evaluation on dental CTs of a case series

    Energy Technology Data Exchange (ETDEWEB)

    Scaravilli, Maria Serena; Mariniello, Mauro [Department of Oral and Maxillo-Facial Sciences, Section of Oral and Implant Surgery, University of Naples ' Federico II' , Naples (Italy); Sammartino, Gilberto, E-mail: serena.scaravilli@gmail.com [Department of Oral and Maxillo-Facial Sciences, Section of Oral and Implant Surgery, University of Naples ' Federico II' , Naples (Italy)

    2010-11-15

    Purpose: The aim of this study was to assess the anatomy of the mandibular lingual foramen (MLF) and its linked canals (mandibular lingual vascular canals - MLVC), describing their frequency, diameter, location, and course. Materials and methods: One hundred and fourteen computed tomography (CT) images of the mandible (57 male and 57 female; mean age 44.70 {+-} 12.53; age range 13-75 years, were evaluated. The CT sections were obtained on axial plane by using a bone reconstruction algorithm and then processed with dedicated software (Dentascan), with a standard protocol. Results: 103 patients (90.35%) had at least one lingual vascular canal and 52 (45.61%) had multiple (two or three) canals. The typical locations of MLVC were the midline of the mandible (median lingual canal [MLC]). The mean diameter of the lingual canals in the midline (MLC) was 0.8 mm {+-} 0. The direction of MLC progresses in an anterior and slightly caudal sense. Conclusions: Dental CT examination easily demonstrates the presence, position, direction and size of the lingual foramen and of the lingual vascular canals of the mandible. Radiologists and oral surgeons should be aware of these canals and their importance, in order to prevent bleeding complications during implants placement and other surgical procedures.

  20. A customized bolus produced using a 3-dimensional printer for radiotherapy.

    Directory of Open Access Journals (Sweden)

    Shin-Wook Kim

    Full Text Available OBJECTIVE: Boluses are used in high-energy radiotherapy in order to overcome the skin sparing effect. In practice though, commonly used flat boluses fail to make a perfect contact with the irregular surface of the patient's skin, resulting in air gaps. Hence, we fabricated a customized bolus using a 3-dimensional (3D printer and evaluated its feasibility for radiotherapy. METHODS: We designed two kinds of bolus for production on a 3D printer, one of which was the 3D printed flat bolus for the Blue water phantom and the other was a 3D printed customized bolus for the RANDO phantom. The 3D printed flat bolus was fabricated to verify its physical quality. The resulting 3D printed flat bolus was evaluated by assessing dosimetric parameters such as D1.5 cm, D5 cm, and D10 cm. The 3D printed customized bolus was then fabricated, and its quality and clinical feasibility were evaluated by visual inspection and by assessing dosimetric parameters such as Dmax, Dmin, Dmean, D90%, and V90%. RESULTS: The dosimetric parameters of the resulting 3D printed flat bolus showed that it was a useful dose escalating material, equivalent to a commercially available flat bolus. Analysis of the dosimetric parameters of the 3D printed customized bolus demonstrated that it is provided good dose escalation and good contact with the irregular surface of the RANDO phantom. CONCLUSIONS: A customized bolus produced using a 3D printer could potentially replace commercially available flat boluses.

  1. A customized bolus produced using a 3-dimensional printer for radiotherapy.

    Science.gov (United States)

    Kim, Shin-Wook; Shin, Hun-Joo; Kay, Chul Seung; Son, Seok Hyun

    2014-01-01

    Boluses are used in high-energy radiotherapy in order to overcome the skin sparing effect. In practice though, commonly used flat boluses fail to make a perfect contact with the irregular surface of the patient's skin, resulting in air gaps. Hence, we fabricated a customized bolus using a 3-dimensional (3D) printer and evaluated its feasibility for radiotherapy. We designed two kinds of bolus for production on a 3D printer, one of which was the 3D printed flat bolus for the Blue water phantom and the other was a 3D printed customized bolus for the RANDO phantom. The 3D printed flat bolus was fabricated to verify its physical quality. The resulting 3D printed flat bolus was evaluated by assessing dosimetric parameters such as D1.5 cm, D5 cm, and D10 cm. The 3D printed customized bolus was then fabricated, and its quality and clinical feasibility were evaluated by visual inspection and by assessing dosimetric parameters such as Dmax, Dmin, Dmean, D90%, and V90%. The dosimetric parameters of the resulting 3D printed flat bolus showed that it was a useful dose escalating material, equivalent to a commercially available flat bolus. Analysis of the dosimetric parameters of the 3D printed customized bolus demonstrated that it is provided good dose escalation and good contact with the irregular surface of the RANDO phantom. A customized bolus produced using a 3D printer could potentially replace commercially available flat boluses.

  2. Safe structural food bolus in elderly: the relevant parameters

    OpenAIRE

    Vandenberghe-Descamps, Mathilde; Septier, Chantal; Prot, Aurélie; Tournier, Carole; Hennequin, Martine; Vigneau, Evelyne; Feron, Gilles; Labouré, Hélène

    2017-01-01

    Mastication is essential to prepare food into a bolus ready to be swallowed safely, with no choking risk. Based on food bolus properties, a masticatory normative indicator was developed by Woda et al. (2010) to identify impaired masticatory function within good oral health population. The aim of the present study was to identify relevant parameters of bolus' structure to differentiate safe to unsafe bolus among elderly contrasting by their dental status.93 elderly, 58% with at least 7 posteri...

  3. MR imaging of the lingual thyroid. Comparison to other submucosal lesions

    International Nuclear Information System (INIS)

    Takashima, S.; Ueda, M.; Shibata, A.; Takayama, F.; Momose, M.; Yamashita, K.

    2001-01-01

    Purpose: To study MR findings for clues to the diagnosis of lingual thyroid. Material and methods: MR findings and clinical and scintigraphic data of 5 cases of lingual thyroid were reviewed and the MR findings were compared to those of 16 cases of other submucosal lesions in the base of the tongue. Results: Four of the 5 patients with lingual thyroid were women and all had hypothyroidism. MR imaging depicted lingual thyroid in the midline in the base of the tongue (n=5) and additional ectopic thyroid glands in the floor of the mouth (n=2) or between the right and left sternohyoid muscles (n=1). Ectopic thyroid glands appeared isointense or hyperintense relative to muscle tissue on T1-weighted images and showed slight or fair contrast enhancement. All glands had low to intermediate T2 signal, which was also seen in 1 case of non-Hodgkin's lymphoma and 1 case of adenoid cystic carcinoma. All ectopic thyroid glands had well-defined margins, whereas malignant tumors tended to have ill-defined margins and to invade the surrounding structures. All but the 5 cases of lingual thyroid had an MR-demonstrable thyroid gland in the normal cervical position. Conclusion: A well-defined mass of low-intermediate T2 signal in the midline base of the tongue, neither with invasive tendency nor with a cervical thyroid gland in the normal site on MR imaging, may strongly indicate lingual thyroid

  4. MR imaging of the lingual thyroid. Comparison to other submucosal lesions

    Energy Technology Data Exchange (ETDEWEB)

    Takashima, S.; Ueda, M.; Shibata, A.; Takayama, F.; Momose, M.; Yamashita, K. [Shinshu Univ. School of Medicine, Matsumoto (Japan). Dept. of Radiology

    2001-03-01

    Purpose: To study MR findings for clues to the diagnosis of lingual thyroid. Material and methods: MR findings and clinical and scintigraphic data of 5 cases of lingual thyroid were reviewed and the MR findings were compared to those of 16 cases of other submucosal lesions in the base of the tongue. Results: Four of the 5 patients with lingual thyroid were women and all had hypothyroidism. MR imaging depicted lingual thyroid in the midline in the base of the tongue (n=5) and additional ectopic thyroid glands in the floor of the mouth (n=2) or between the right and left sternohyoid muscles (n=1). Ectopic thyroid glands appeared isointense or hyperintense relative to muscle tissue on T1-weighted images and showed slight or fair contrast enhancement. All glands had low to intermediate T2 signal, which was also seen in 1 case of non-Hodgkin's lymphoma and 1 case of adenoid cystic carcinoma. All ectopic thyroid glands had well-defined margins, whereas malignant tumors tended to have ill-defined margins and to invade the surrounding structures. All but the 5 cases of lingual thyroid had an MR-demonstrable thyroid gland in the normal cervical position. Conclusion: A well-defined mass of low-intermediate T2 signal in the midline base of the tongue, neither with invasive tendency nor with a cervical thyroid gland in the normal site on MR imaging, may strongly indicate lingual thyroid.

  5. 21 CFR 520.1660c - Oxytetracycline hydrochloride tablets/boluses.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Oxytetracycline hydrochloride tablets/boluses. 520....1660c Oxytetracycline hydrochloride tablets/boluses. (a) Specifications. Each tablet or bolus contains 250, 500, or 1,000 milligrams of oxytetracycline hydrochloride. (b) Sponsors. For sponsors in § 510...

  6. Frequency of lingual nerve injury in mandibular third molar extraction: A comparison of two surgical techniques

    International Nuclear Information System (INIS)

    Shad, S.; Abbasi, M.M.

    2015-01-01

    Background: Surgical removal of impacted mandibular third molar is associated with a number of complications including postoperative bleeding, dry socket, postoperative infection, and injury to regional nerves. Lingual nerve damage is one of the main complications. To prevent this complication different techniques had been used. Lingual flap reflection is one of these procedures in which lingual soft tissue is reflected and retracted deliberately, the nerve is identified and is kept out of the surgical field. The objective of this study was to evaluate a surgical technique for third molar removal which is associated with minimum frequency of lingual nerve damage. Method: A randomized controlled trial was performed. A total of 380 patients with impacted mandibular third molars were included in this study. Each patient was allotted randomly by blocked randomization to group A where procedure was performed by reflection and retraction of lingual flap in addition to buccal flap and group B where procedure was performed by retraction of buccal flap only. Results: Lingual nerve damage occurred in 8.94 percentage in Group A in which lingual flap retraction was performed but damage was reversible. In group B, 2.63 percentage lingual nerve damage was observed and nature of damage was permanent. The difference was statistically significant (p=0.008). Conclusions: Lingual flap retraction poses 3.4 times increased risk of lingual nerve damage during extraction of mandibular third molar when lingual flap is retracted but the nature of damage is reversible. (author)

  7. SU-C-213-06: Dosimetric Verification of 3D Printed Electron Bolus

    International Nuclear Information System (INIS)

    Rasmussen, K; Corbett, M; Pelletier, C; Huang, Z; Feng, Y; Jung, J

    2015-01-01

    Purpose: To determine the dosimetric effect of 3D printed bolus in an anthropomorphic phantom. Methods: Conformable bolus material was generated for an anthropomorphic phantom from a DICOM volume. The bolus generated was a uniform expansion of 5mm applied to the nose region of the phantom, as this is a difficult area to uniformly apply bolus clinically. A Printrbot metal 3D Printer using PLA plastic generated the bolus. A 9MeV anterior beam with a 5cm cone was used to deliver dose to the nose of the phantom. TLD measurements were compared to predicted values at the phantom surface. Film planes were analyzed for the printed bolus, a standard 5mm bolus sheet placed on the phantom, and the phantom with no bolus applied to determine depth and dose distributions. Results: TLDs measured within 2.5% of predicted value for the 3D bolus. Film demonstrated a more uniform dose distribution in the nostril region for the 3d printed bolus than the standard bolus. This difference is caused by the air gap created around the nostrils by the standard bolus, creating a secondary build-up region. Both demonstrated a 50% central axis dose shift of 5mm relative to the no bolus film. HU for the bolus calculated the PLA electron density to be ∼1.1g/cc. Physical density was measured to be 1.3g/cc overall. Conclusion: 3D printed PLA bolus demonstrates improved dosimetric performance to standard bolus for electron beams with complex phantom geometry

  8. SU-C-213-06: Dosimetric Verification of 3D Printed Electron Bolus

    Energy Technology Data Exchange (ETDEWEB)

    Rasmussen, K; Corbett, M; Pelletier, C; Huang, Z; Feng, Y; Jung, J [East Carolina Univ, Greenville, NC (United States)

    2015-06-15

    Purpose: To determine the dosimetric effect of 3D printed bolus in an anthropomorphic phantom. Methods: Conformable bolus material was generated for an anthropomorphic phantom from a DICOM volume. The bolus generated was a uniform expansion of 5mm applied to the nose region of the phantom, as this is a difficult area to uniformly apply bolus clinically. A Printrbot metal 3D Printer using PLA plastic generated the bolus. A 9MeV anterior beam with a 5cm cone was used to deliver dose to the nose of the phantom. TLD measurements were compared to predicted values at the phantom surface. Film planes were analyzed for the printed bolus, a standard 5mm bolus sheet placed on the phantom, and the phantom with no bolus applied to determine depth and dose distributions. Results: TLDs measured within 2.5% of predicted value for the 3D bolus. Film demonstrated a more uniform dose distribution in the nostril region for the 3d printed bolus than the standard bolus. This difference is caused by the air gap created around the nostrils by the standard bolus, creating a secondary build-up region. Both demonstrated a 50% central axis dose shift of 5mm relative to the no bolus film. HU for the bolus calculated the PLA electron density to be ∼1.1g/cc. Physical density was measured to be 1.3g/cc overall. Conclusion: 3D printed PLA bolus demonstrates improved dosimetric performance to standard bolus for electron beams with complex phantom geometry.

  9. Fabrication of malleable three-dimensional-printed customized bolus using three-dimensional scanner.

    Directory of Open Access Journals (Sweden)

    Jae Won Park

    Full Text Available A three-dimensional (3D-printed customized bolus (3D bolus can be used for radiotherapy application to irregular surfaces. However, bolus fabrication based on computed tomography (CT scans is complicated and also delivers unwanted irradiation. Consequently, we fabricated a bolus using a 3D scanner and evaluated its efficacy. The head of an Alderson Rando phantom was scanned with a 3D scanner. The 3D surface data were exported and reconstructed with Geomagic Design X software. A 3D bolus of 5-mm thickness designed to fit onto the nose was printed with the use of rubber-like printing material, and a radiotherapy plan was developed. We successfully fabricated the customized 3D bolus, and further, a CT simulation indicated an acceptable fit of the 3D bolus to the nose. There was no air gap between the bolus and the phantom surface. The percent depth dose (PDD curve of the phantom with the 3D bolus showed an enhanced surface dose when compared with that of the phantom without the bolus. The PDD of the 3D bolus was comparable with that of a commercial superflab bolus. The radiotherapy plan considering the 3D bolus showed improved target coverage when compared with that without the bolus. Thus, we successfully fabricated a customized 3D bolus for an irregular surface using a 3D scanner instead of a CT scanner.

  10. Qualitative indices and enhancement rate of CT pulmonary angiography in patients with suspected pulmonary embolism: Comparison between test bolus and bolus-tracking methods

    Directory of Open Access Journals (Sweden)

    Maryam Moradi

    2016-01-01

    Full Text Available Background: The aim of the present study was to assess the qualitative indices and enhancement rate of computed tomographic pulmonary angiography (CTPA in patients with suspected pulmonary embolism using Test bolus and Bolus-tracking techniques. Materials and Methods: Fifty-two patients with suspected pulmonary embolism that passed informed consent were randomly divided in the two groups. In each group, demographic characteristics, qualitative indices, and enhancement rate of CTPA were recorded. Results: The diagnostic result obtained in majority of the participants in the two groups (88.5 % in Test bolus group vs. 73.1% in the Bolus tracking group. In the case of quantitative variables, no statistically significant differences were found between the groups (P > 0.05. The only statistically significant difference between the two groups is average of "X-ray dose". Conclusion: The results of our study show that there is no statistically significant difference between the Bolus Tracking and Test Bolus techniques for producing more homogeneous enhancement.

  11. Lingual Abscess in the Setting of Recent Periodontal Antibiotic Injections.

    Science.gov (United States)

    Lefler, Joshua E; Masullo, Lawrence N

    2016-10-01

    Lingual abscess is a rare clinical entity, with posterior involvement being much less common than anterior involvement. Typical inciting events include trauma or direct inoculation to the area. The clinical diagnosis can be difficult, and early imaging and specialist consultation should be pursued to make a definitive diagnosis and to prevent patient deterioration. We present a case of posterior lingual abscess in a 62-year-old man after he received antibiotic injections to the lower molars for periodontal disease. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: Lingual abscess is a rare condition that is difficult to diagnose clinically. Misdiagnosis or delayed diagnosis can lead to acute airway compromise and increased morbidity. Published by Elsevier Inc.

  12. Digital lingual orthodontics and temporary anchorage devices for efficient biomechanics

    Directory of Open Access Journals (Sweden)

    Pravin Shetty

    2016-01-01

    Full Text Available Adult patients seeking orthodontic treatment at all times present with an esthetic demand even during treatment. The lingual orthodontics, apart from its esthetic values, also presents several other advantages. Currently, it has become a complete system in itself, starting from an accurate diagnosis, treatment protocol, and laboratory procedure to placement of the appliance in the patient′s mouth. With the advent of computer-aided design/computer-aided manufacturing system, the lingual orthodontics is more evolved and made ease operators in respect to more efficient mechanics and reduced archwire adjustments. The present article presents two cases to show the efficiency of lingual orthodontics with temporary anchorage devices and anterior retraction hook.

  13. Acute dystonic reaction leading to lingual hematoma mimicking angioedema

    Science.gov (United States)

    Sezer, Özgür; Aydin, Ali Attila; Bilge, Sedat; Arslan, Fatih; Arslan, Hasan

    2017-01-01

    Lingual hematoma is a severe situation, which is rare and endangers the airway. It can develop due to trauma, vascular abnormalities, and coagulopathy. Due to its sudden development, it can be clinically confused with angioedema. In patients who applied to the doctor with complaints of a swollen tongue, lingual hematoma can be confused with angioedema, in particular, at the beginning if the symptoms occurred after drug use. It should especially be considered that dystonia in the jaw can present as drug-induced hyperkinetic movement disorder. Early recognition of this rare clinical condition and taking precautions for providing airway patency are essential. In this case report, we will discuss mimicking angioedema and caused by a bite due to dystonia and separation of the tongue from the base of the mouth developing concurrently with lingual hematoma. PMID:29326495

  14. Involuntary craniofacial lingual movements in intensive care-acquired quadriplegia.

    Science.gov (United States)

    Cartagena, A M; Jog, M; Young, G B

    2012-02-01

    The syndrome of involuntary craniofacial lingual movements in the setting of acute intensive care-acquired quadriplegia (critical illness neuromyopathy) following sepsis-associated encephalopathy has not been previously described. We suggest a localization and treatment for this disabling condition. Three patients (2 female) from our center were quadriplegic from critical illness neuromyopathy when they developed involuntary craniofacial lingual movements following sepsis-associated encephalopathy. Extensive investigations failed to identify an etiology for the abnormal movements. Movements were of large amplitude, of moderate speed, and semi-rhythmic in the jaw, tongue, and palate, persistent and extremely bothersome to all patients. Injection with Botulinum toxin type A was very beneficial. Involuntary craniofacial lingual movements in the setting of flaccid quadriplegia following sepsis-associated encephalopathy are consistent with focal craniofacial brainstem myoclonus and constitutes a new syndrome. Botulinum toxin type A treatment maybe helpful in treatment.

  15. Optical tracking of contrast medium bolus to optimize bolus shape and timing in dynamic computed tomography

    International Nuclear Information System (INIS)

    Eisa, Fabian; Brauweiler, Robert; Peetz, Alexander; Hupfer, Martin; Nowak, Tristan; Kalender, Willi A

    2012-01-01

    One of the biggest challenges in dynamic contrast-enhanced CT is the optimal synchronization of scan start and duration with contrast medium administration in order to optimize image contrast and to reduce the amount of contrast medium. We present a new optically based approach, which was developed to investigate and optimize bolus timing and shape. The time-concentration curve of an intravenously injected test bolus of a dye is measured in peripheral vessels with an optical sensor prior to the diagnostic CT scan. The curves can be used to assess bolus shapes as a function of injection protocols and to determine contrast medium arrival times. Preliminary results for phantom and animal experiments showed the expected linear behavior between dye concentration and absorption. The kinetics of the dye was compared to iodinated contrast medium and was found to be in good agreement. The contrast enhancement curves were reliably detected in three mice with individual bolus shapes and delay times of 2.1, 3.5 and 6.1 s, respectively. The optical sensor appears to be a promising approach to optimize injection protocols and contrast enhancement timing and is applicable to all modalities without implying any additional radiation dose. Clinical tests are still necessary. (note)

  16. The Mutual Symbiosis between Inclusive Bi-Lingual Education and Multicultural Education

    Science.gov (United States)

    Irby, Beverly J.; Tong, Fuhui; Lara-Alecio, Rafael

    2011-01-01

    In this article the authors postulate a mutual symbiosis between multicultural and inclusive bi-lingual education. Combining bi-lingual and multicultural education to create a symbiotic relationship can stimulate reform in schools and can promote inclusive educational systems, thereby keeping native languages and cultures alive for minority…

  17. Thyroglossal Duct Papillary Thyroid Carcinoma and Synchronous Lingual Thyroid Atypia

    Directory of Open Access Journals (Sweden)

    Timothy Yoo

    2016-01-01

    Full Text Available Thyroglossal duct and lingual thyroid ectopic lesions are exceedingly rare synchronous findings. Papillary thyroid carcinoma of these ectopic thyroid sites is well understood but still a rare finding. This case points to some management nuances in regard to ectopic thyroid screening with imaging and also shows the effectiveness of minimally invasive transoral robotic surgery for lingual thyroid.

  18. The anatomic basis of lingual nerve trauma associated with inferior alveolar block injections.

    Science.gov (United States)

    Morris, Christopher D; Rasmussen, Jared; Throckmorton, Gaylord S; Finn, Richard

    2010-11-01

    This study describes the anatomic variability in the position of the lingual nerve in the pterygomandibular space, the location of the inferior alveolar nerve block injection. Simulated standard landmark-based inferior alveolar nerve blocks were administered to 44 fixed sagitally bisected cadaver heads. Measurements were made of the diameter of the nerves and distances between the needle and selected anatomic landmarks and the nerves. Of 44 simulated injections, 42 (95.5%) passed lateral to the lingual nerve, 7 (16%) passed within 0.1 mm of the nerve, and 2 (4.5%) penetrated the nerve. The position of the lingual nerve relative to bony landmarks within the interpterygoid fascia was highly variable. Variation in the position of the lingual nerve is an important contributor to lingual nerve trauma during inferior alveolar block injections. This factor should be an important part of preoperative informed consent. Copyright © 2010 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  19. Fat digestion in the stomach: stability of lingual lipase in the gastric environment.

    Science.gov (United States)

    Fink, C S; Hamosh, P; Hamosh, M

    1984-03-01

    Digestion of dietary fat starts in the stomach, where lingual lipase hydrolyzes triglycerides to free fatty acids and partial glycerides at pH 3.0-6.0. Lingual lipase is secreted continuously from lingual serous glands and accumulates in the stomach between meals, when gastric pH is less than 3.0. We have, therefore, examined the resistance of lingual lipase to low pH and its possible protection by dietary components present in the stomach contents. Partially purified rat lingual lipase (7-15 micrograms enzyme protein) was preincubated at 37 degrees C for 10-60 min at pH 1.0-6.0 before incubation for assay of lipolytic activity, hydrolysis of tri-[3H]olein at pH 5.4. The data show that partially purified rat lingual lipase preparations are stable at 37 degrees C in the pH range of 2.5-6.0. Enzyme activity, however, is rapidly and irreversibly lost during preincubation at pH 1.0-2.4 for 10-30 min. Protein (gelatin 1% or albumin 1% or 2.5%) cannot prevent the inactivation of lingual lipase at low pH. The large molecular species (molecular weight greater than 500,000) of lingual lipase (thought to be an aggregate of enzyme with lipids) is slightly more resistant to inactivation than the 46,000 dalton preparation, suggesting that lipids might protect the enzyme from inactivation. Indeed, about 60% of the initial lipase activity is preserved during incubation at pH 2.0 in the presence of 50 mM lecithin or 10 mM triolein. The data indicate that triglycerides which are hydrolyzed by this enzyme as well as phospholipids that are not hydrolyzed can prevent the inactivation of the enzyme.(ABSTRACT TRUNCATED AT 250 WORDS)

  20. Correlations between aorto-popliteal bolus transit speed and aortic and popliteal bolus transit time during CT angiography of aortoiliac and lower extremity arteries

    Energy Technology Data Exchange (ETDEWEB)

    Nakaya, Yasuhiro, E-mail: y-nakaya@radiol.med.osaka-u.ac.jp [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita City, Osaka 565-0871 (Japan); Kim, Tonsok; Hori, Masatoshi; Onishi, Hiromitsu; Nakamoto, Atsushi; Tsuboyama, Takahiro; Maeda, Noboru; Higashihara, Hiroki; Tomoda, Kaname; Nakamura, Hironobu [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita City, Osaka 565-0871 (Japan)

    2011-08-15

    Purpose: The purpose of this study was to investigate correlations between the aorto-popliteal bolus transit speed and aortic and popliteal bolus transit time in order to evaluate the possibility for prediction of bolus transit speed by single test injection technique. Materials and methods: Approval was obtained from our institutional review board for this study, which included 42 patients, from all of whom written informed consent was obtained. Low-dose serial CT scanning after injection of 12 ml contrast material (300 mg/ml) at a rate of 3 ml/s followed by saline flush was performed twice, first at the level of the upper abdomen and second at the level of the knee joint. The times needed to reach peak enhancement of the upper abdominal aorta (T-aorta) and bilateral popliteal arteries (T-popliteal) were obtained, and aorto-popliteal bolus transit speeds between the abdominal aorta and popliteal arteries were calculated. ABI was recorded for the bilateral feet. The Pearson's product-moment correlation coefficient was used to investigate the correlation between the bolus transit speed and T-aorta, T-popliteal, ABI, and patient age. Result: The respective correlation coefficients for bolus transit speed on the one hand and T-aorta, T-popliteal, ABI, patient age on the other were -0.50, -0.84, 0.36, and -0.52. Conclusion: The time to peak enhancement for popliteal arteries showed the strongest correlation with aorto-popliteal bolus transit speeds, and was considered to be the most accurate predictor for aorto-popliteal bolus transit speeds.

  1. Different Approaches to Cross-Lingual Focus Groups

    Directory of Open Access Journals (Sweden)

    Maira Quintanilha

    2015-12-01

    Full Text Available Focus groups are a useful data-generation strategy in qualitative health research when it is important to understand how social contexts shape participants’ health. However, when cross-lingual focus groups are conducted across cultural groups, and in languages in which the researcher is not fluent, questions regarding the usefulness and rigor of the findings can be raised. In this article, we will discuss three different approaches to cross-lingual focus groups used in a community-based participatory research project with pregnant and postpartum, African immigrant women in Alberta, Canada. In two approaches, we moderated focus groups in women’s mother tongue with the support of real-time interpreters, but in the first approach, audio recording was used and in the second approach, audio recording was not used. In the third approach, a bilingual moderator facilitated focus groups in women’s mother tongue, with transcription and translation of audio-recorded data upon completion of data generation. We will describe each approach in detail, including their advantages and challenges, and recontextualize what we have learned within the known literature. We expect the lessons learned in this project may assist others in planning and implementing cross-lingual focus groups, especially in the context of community-based participatory research.

  2. SU-C-213-03: Custom 3D Printed Boluses for Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, B; Yang, M; Yan, Y; Rahimi, A; Chopra, R; Jiang, S [UT Southwestern Medical Center, Dallas, TX (United States)

    2015-06-15

    Purpose: To develop a clinical workflow and to commission the process of creating custom 3d printed boluses for radiation therapy. Methods: We designed a workflow to create custom boluses using a commercial 3D printer. Contours of several patients were deformably mapped to phantoms where the test bolus contours were designed. Treatment plans were created on the phantoms following our institutional planning guideline. The DICOM file of the bolus contours were then converted to stereoLithography (stl) file for the 3d printer. The boluses were printed on a commercial 3D printer using polylactic acid (PLA) material. Custom printing parameters were optimized in order to meet the requirement of bolus composition. The workflow was tested on multiple anatomical sites such as skull, nose and chest wall. The size of boluses varies from 6×9cm2 to 12×25cm2. To commission the process, basic CT and dose properties of the printing materials were measured in photon and electron beams and compared against water and soft superflab bolus. Phantoms were then scanned to confirm the placement of custom boluses. Finally dose distributions with rescanned CTs were compared with those computer-generated boluses. Results: The relative electron density(1.08±0.006) of the printed boluses resemble those of liquid tap water(1.04±0.004). The dosimetric properties resemble those of liquid tap water(1.04±0.004). The dosimetric properties were measured at dmax with an ion chamber in electron and photon open beams. Compared with solid water and soft bolus, the output difference was within 1% for the 3D printer material. The printed boluses fit well to the phantom surfaces on CT scans. The dose distribution and DVH based on the printed boluses match well with those based on TPS generated boluses. Conclusion: 3d printing provides a cost effective and convenient solution for patient-specific boluses in radiation therapy.

  3. SU-C-213-03: Custom 3D Printed Boluses for Radiation Therapy

    International Nuclear Information System (INIS)

    Zhao, B; Yang, M; Yan, Y; Rahimi, A; Chopra, R; Jiang, S

    2015-01-01

    Purpose: To develop a clinical workflow and to commission the process of creating custom 3d printed boluses for radiation therapy. Methods: We designed a workflow to create custom boluses using a commercial 3D printer. Contours of several patients were deformably mapped to phantoms where the test bolus contours were designed. Treatment plans were created on the phantoms following our institutional planning guideline. The DICOM file of the bolus contours were then converted to stereoLithography (stl) file for the 3d printer. The boluses were printed on a commercial 3D printer using polylactic acid (PLA) material. Custom printing parameters were optimized in order to meet the requirement of bolus composition. The workflow was tested on multiple anatomical sites such as skull, nose and chest wall. The size of boluses varies from 6×9cm2 to 12×25cm2. To commission the process, basic CT and dose properties of the printing materials were measured in photon and electron beams and compared against water and soft superflab bolus. Phantoms were then scanned to confirm the placement of custom boluses. Finally dose distributions with rescanned CTs were compared with those computer-generated boluses. Results: The relative electron density(1.08±0.006) of the printed boluses resemble those of liquid tap water(1.04±0.004). The dosimetric properties resemble those of liquid tap water(1.04±0.004). The dosimetric properties were measured at dmax with an ion chamber in electron and photon open beams. Compared with solid water and soft bolus, the output difference was within 1% for the 3D printer material. The printed boluses fit well to the phantom surfaces on CT scans. The dose distribution and DVH based on the printed boluses match well with those based on TPS generated boluses. Conclusion: 3d printing provides a cost effective and convenient solution for patient-specific boluses in radiation therapy

  4. [Surgery of lower third molars and lesions of the lingual nerve].

    Science.gov (United States)

    Chiapasco, M; Pedrinazzi, M; Motta, J; Crescentini, M; Ramundo, G

    1996-11-01

    The authors describe a technical expedient applied during the removal of totally or partially impacted lower third molars, in order to prevent lingual nerve damage. EXPERIMENTAL ASSAY: Retrospective study. The sample includes 1835 extractions of totally or partially impacted lower third molars, performed on 1030 patients, 493 males and 537 females, aging between 12 and 72 years. All the operations were carried out under local anaesthesia with standardization of the surgical protocol. A mucoperiosteal paramarginal flap was used in case of germectomy, whereas a mucoperiosteal marginal flap with mesial releasing incision was used in case of fully mature teeth. Ostectomy and tooth sectioning were performed using a round and fissure bur respectively, assembled on a straight low-speed handpiece and under irrigation with sterile saline. The authors reported only one case of transient lingual nerve paresthesia (0.05%) which occurred in a 19-years old female presenting a totally impacted third molar mesial-lingual inclination. Symptoms disappeared spontaneously one week postoperatively. Therefore the overall incidence of permanent nerve damage was equal to 0%. The data reported in literature show a lingual nerve lesion incidence ranging between 0% and 22%. With this simple surgical expedient the incidence of permanent lingual damage was 0%. Thus, it is the authors' opinion that this simple expedient should be applied in all cases of impacted third molar removal.

  5. Esophageal Transit, Contraction and Perception of Transit After Swallows of Two Viscous Boluses.

    Science.gov (United States)

    Dalmazo, Jucileia; Aprile, Lilian Rose Otoboni; Dantas, Roberto Oliveira

    2015-10-01

    There have been results showing the influence of bolus viscosities and consistency on esophageal motility and transit. However, there is no description about the influence of two different viscous boluses on esophageal contractions, bolus transit and perception of transit. Our objective in this investigation was to evaluate the esophageal transit and contraction after swallows of two viscous boluses. By impedance and manometric methods, we measured the esophageal transit and contraction after swallows of two viscous boluses of 5 mL volume, 100% barium sulfate and yogurt, swallowed in duplicate in the supine and upright positions. The bolus transit, esophageal contractions and the perception of bolus transit through the esophagus were evaluated in both positions. Impedance and contraction were measured at 5, 10, 15 and 20 cm from the lower esophageal sphincter. After each swallow, the volunteers were asked about the sensation of bolus transit through the esophagus. In supine position, the yogurt had a less frequent complete bolus transit than barium. Also in the supine position, the esophageal transit was longer with yogurt than with barium. Esophageal contractions after swallows were similar between barium and yogurt boluses. There was no difference in perception of transit between the two boluses. Although both 100% barium sulfate and yogurt are viscous boluses and have similar viscosities, the transit through the esophagus is slower with yogurt bolus than with barium bolus, which suggests that viscosity may be not the sole factor to determine transit.

  6. Displacement pattern of the anterior segment using antero-posterior lingual retractor combined with a palatal plate

    OpenAIRE

    Seo, Kyung-Won; Kwon, Soon-Yong; Kim, Kyung A; Park, Ki-Ho; Kim, Seong-Hun; Ahn, Hyo-Won; Nelson, Gerald

    2015-01-01

    Objective To evaluate and compare the effects of two appliances on the en masse retraction of the anterior teeth anchored by temporary skeletal anchorage devices (TSADs). Methods The sample comprised 46 nongrowing hyperdivergent adult patients who planned to undergo upper first premolar extraction using lingual retractors. They were divided into three groups, based on the lingual appliance used: the C-lingual retractor (CLR) group (group 1, n = 16) and two antero-posterior lingual retractor (...

  7. On bolus for megavoltage photon and electron radiation therapy

    International Nuclear Information System (INIS)

    Vyas, Vedang; Palmer, Lisa; Mudge, Ray; Jiang, Runqing; Fleck, Andre; Schaly, Bryan; Osei, Ernest; Charland, Paule

    2013-01-01

    Frequently, in radiation therapy one must treat superficial lesions on cancer patients; these are at or adjacent to the skin. Megavoltage photon radiotherapy penetrates through the skin to irradiate deep-seated tumors, with skin-sparing property. Hence, to treat superficial lesions, one must use a layer of scattering material to feign as the skin surface. Although megavoltage electron beams are used for superficial treatments, one occasionally needs to enhance the dose near the surface. Such is the function of a “bolus,” a natural or synthetically developed material that acts as a layer of tissue to provide a more effective treatment to the superficial lesions. Other uses of boluses are to correct for varying surface contours and to add scattering material around the patient's surface. Materials used as bolus vary from simple water to metal and include various mixtures and compounds. Even with the modernization of the technology for external-beam therapy and the emergence of various commercial boluses, the preparation and utilization of a bolus in clinical radiotherapy remains an art. Considering the varying experiences and practices, this paper briefly summarizes available boluses that have been proposed and are employed in clinical radiotherapy. Although this review is not exhaustive, it provides some initial guidance and answers questions that may arise in clinical practice

  8. A permeability barrier surrounds taste buds in lingual epithelia

    Science.gov (United States)

    Dando, Robin; Pereira, Elizabeth; Kurian, Mani; Barro-Soria, Rene; Chaudhari, Nirupa

    2014-01-01

    Epithelial tissues are characterized by specialized cell-cell junctions, typically localized to the apical regions of cells. These junctions are formed by interacting membrane proteins and by cytoskeletal and extracellular matrix components. Within the lingual epithelium, tight junctions join the apical tips of the gustatory sensory cells in taste buds. These junctions constitute a selective barrier that limits penetration of chemosensory stimuli into taste buds (Michlig et al. J Comp Neurol 502: 1003–1011, 2007). We tested the ability of chemical compounds to permeate into sensory end organs in the lingual epithelium. Our findings reveal a robust barrier that surrounds the entire body of taste buds, not limited to the apical tight junctions. This barrier prevents penetration of many, but not all, compounds, whether they are applied topically, injected into the parenchyma of the tongue, or circulating in the blood supply, into taste buds. Enzymatic treatments indicate that this barrier likely includes glycosaminoglycans, as it was disrupted by chondroitinase but, less effectively, by proteases. The barrier surrounding taste buds could also be disrupted by brief treatment of lingual tissue samples with DMSO. Brief exposure of lingual slices to DMSO did not affect the ability of taste buds within the slice to respond to chemical stimulation. The existence of a highly impermeable barrier surrounding taste buds and methods to break through this barrier may be relevant to basic research and to clinical treatments of taste. PMID:25209263

  9. A permeability barrier surrounds taste buds in lingual epithelia.

    Science.gov (United States)

    Dando, Robin; Pereira, Elizabeth; Kurian, Mani; Barro-Soria, Rene; Chaudhari, Nirupa; Roper, Stephen D

    2015-01-01

    Epithelial tissues are characterized by specialized cell-cell junctions, typically localized to the apical regions of cells. These junctions are formed by interacting membrane proteins and by cytoskeletal and extracellular matrix components. Within the lingual epithelium, tight junctions join the apical tips of the gustatory sensory cells in taste buds. These junctions constitute a selective barrier that limits penetration of chemosensory stimuli into taste buds (Michlig et al. J Comp Neurol 502: 1003-1011, 2007). We tested the ability of chemical compounds to permeate into sensory end organs in the lingual epithelium. Our findings reveal a robust barrier that surrounds the entire body of taste buds, not limited to the apical tight junctions. This barrier prevents penetration of many, but not all, compounds, whether they are applied topically, injected into the parenchyma of the tongue, or circulating in the blood supply, into taste buds. Enzymatic treatments indicate that this barrier likely includes glycosaminoglycans, as it was disrupted by chondroitinase but, less effectively, by proteases. The barrier surrounding taste buds could also be disrupted by brief treatment of lingual tissue samples with DMSO. Brief exposure of lingual slices to DMSO did not affect the ability of taste buds within the slice to respond to chemical stimulation. The existence of a highly impermeable barrier surrounding taste buds and methods to break through this barrier may be relevant to basic research and to clinical treatments of taste. Copyright © 2015 the American Physiological Society.

  10. Modeling the retention of rumen boluses for the electronic identification of goats.

    Science.gov (United States)

    Carné, S; Caja, G; Ghirardi, J J; Salama, A A K

    2011-02-01

    We constructed a regression model to estimate the retention of electronic boluses in goats. With this aim, 2,482 boluses were administered to goats from dairy (Murciano-Granadina, n=1,326; French Alpine, n=381) and meat (Blanca de Rasquera, n=532) breeds. A total of 19 bolus types made of materials (ceramic, plastic tubes filled with concrete or silicone, and ballasts) differing in their specific gravity (SG) were used, thereby obtaining a wide variation in bolus features: diameter (9 to 22 mm), length (37 to 84 mm), weight (5 to 111 g), volume (2.6 to 26 mL), and SG (1.0 to 5.5). Each bolus contained a half-duplex glass encapsulated transponder (32 × 3.8mm) and was administered using adapted balling guns. Murciano-Granadina and Blanca de Rasquera goats also wore 2 visual plastic ear tags: V1 (double flag, 5.1g) and V2 (flag-button, 4.2g). No data on ear tags in French Alpine goats was available. Bolus and ear tag retention [(retained/monitored) × 100] was recorded for at least 1 yr. Dynamic reading efficiency [(dynamic reading/static reading) × 100] was also evaluated from 1,496 bolus readings. No administration incidences or apparent negative behavior or performance effects were observed for any bolus type. Static reading efficiency of retained boluses was 100%, except for the prototypes with metal ballasts, which yielded a 93.3% reading efficiency. Retention of metal-ballasted boluses was confirmed using x-ray equipment. Excluding ballasted boluses, a 99.5% dynamic reading efficiency was obtained. Ear tag losses were 6.5% for V1 and 3.7% for V2, ranging from 3.2 to 7.8% depending on ear tag type and goat breed. Bolus retention varied (0 to 100%) according to their physical features. Obtained data allowed the fitting of a logistic model of bolus retention rate according to bolus volume and weight (R(2) = 0.98); the SG was implicitly considered. Estimated weight and SG to produce medium- (15 mL) and standard-sized (22 mL) boluses for 99.95% retention rate in

  11. Intravenous Tranexamic Acid Bolus plus Infusion Is Not More Effective than a Single Bolus in Primary Hip Arthroplasty: A Randomized Controlled Trial.

    Science.gov (United States)

    Zufferey, Paul J; Lanoiselée, Julien; Chapelle, Céline; Borisov, Dmitry B; Bien, Jean-Yves; Lambert, Pierre; Philippot, Rémi; Molliex, Serge; Delavenne, Xavier

    2017-09-01

    Preoperative administration of the antifibrinolytic agent tranexamic acid reduces bleeding in patients undergoing hip arthroplasty. Increased fibrinolytic activity is maintained throughout the first day postoperation. The objective of the study was to determine whether additional perioperative administration of tranexamic acid would further reduce blood loss. This prospective, double-blind, parallel-arm, randomized, superiority study was conducted in 168 patients undergoing unilateral primary hip arthroplasty. Patients received a preoperative intravenous bolus of 1 g of tranexamic acid followed by a continuous infusion of either tranexamic acid 1 g (bolus-plus-infusion group) or placebo (bolus group) for 8 h. The primary outcome was calculated perioperative blood loss up to day 5. Erythrocyte transfusion was implemented according to a restrictive transfusion trigger strategy. The mean perioperative blood loss was 919 ± 338 ml in the bolus-plus-infusion group (84 patients analyzed) and 888 ± 366 ml in the bolus group (83 patients analyzed); mean difference, 30 ml (95% CI, -77 to 137; P = 0.58). Within 6 weeks postsurgery, three patients in each group (3.6%) underwent erythrocyte transfusion and two patients in the bolus group experienced distal deep-vein thrombosis. A meta-analysis combining data from this study with those of five other trials showed no incremental efficacy of additional perioperative administration of tranexamic acid. A preoperative bolus of tranexamic acid, associated with a restrictive transfusion trigger strategy, resulted in low erythrocyte transfusion rates in patients undergoing hip arthroplasty. Supplementary perioperative administration of tranexamic acid did not achieve any further reduction in blood loss.

  12. Role of physical bolus properties as sensory inputs in the trigger of swallowing.

    Science.gov (United States)

    Peyron, Marie-Agnès; Gierczynski, Isabelle; Hartmann, Christoph; Loret, Chrystel; Dardevet, Dominique; Martin, Nathalie; Woda, Alain

    2011-01-01

    Swallowing is triggered when a food bolus being prepared by mastication has reached a defined state. However, although this view is consensual and well supported, the physical properties of the swallowable bolus have been under-researched. We tested the hypothesis that measuring bolus physical changes during the masticatory sequence to deglutition would reveal the bolus properties potentially involved in swallowing initiation. Twenty normo-dentate young adults were instructed to chew portions of cereal and spit out the boluses at different times in the masticatory sequence. The mechanical properties of the collected boluses were measured by a texture profile analysis test currently used in food science. The median particle size of the boluses was evaluated by sieving. In a simultaneous sensory study, twenty-five other subjects expressed their perception of bolus texture dominating at any mastication time. Several physical changes appeared in the food bolus as it was formed during mastication: (1) in rheological terms, bolus hardness rapidly decreased as the masticatory sequence progressed, (2) by contrast, adhesiveness, springiness and cohesiveness regularly increased until the time of swallowing, (3) median particle size, indicating the bolus particle size distribution, decreased mostly during the first third of the masticatory sequence, (4) except for hardness, the rheological changes still appeared in the boluses collected just before swallowing, and (5) physical changes occurred, with sensory stickiness being described by the subjects as a dominant perception of the bolus at the end of mastication. Although these physical and sensory changes progressed in the course of mastication, those observed just before swallowing seem to be involved in swallowing initiation. They can be considered as strong candidates for sensory inputs from the bolus that are probably crucially involved in the triggering of swallowing, since they appeared in boluses prepared in various

  13. Role of physical bolus properties as sensory inputs in the trigger of swallowing.

    Directory of Open Access Journals (Sweden)

    Marie-Agnès Peyron

    Full Text Available BACKGROUND: Swallowing is triggered when a food bolus being prepared by mastication has reached a defined state. However, although this view is consensual and well supported, the physical properties of the swallowable bolus have been under-researched. We tested the hypothesis that measuring bolus physical changes during the masticatory sequence to deglutition would reveal the bolus properties potentially involved in swallowing initiation. METHODS: Twenty normo-dentate young adults were instructed to chew portions of cereal and spit out the boluses at different times in the masticatory sequence. The mechanical properties of the collected boluses were measured by a texture profile analysis test currently used in food science. The median particle size of the boluses was evaluated by sieving. In a simultaneous sensory study, twenty-five other subjects expressed their perception of bolus texture dominating at any mastication time. FINDINGS: Several physical changes appeared in the food bolus as it was formed during mastication: (1 in rheological terms, bolus hardness rapidly decreased as the masticatory sequence progressed, (2 by contrast, adhesiveness, springiness and cohesiveness regularly increased until the time of swallowing, (3 median particle size, indicating the bolus particle size distribution, decreased mostly during the first third of the masticatory sequence, (4 except for hardness, the rheological changes still appeared in the boluses collected just before swallowing, and (5 physical changes occurred, with sensory stickiness being described by the subjects as a dominant perception of the bolus at the end of mastication. CONCLUSIONS: Although these physical and sensory changes progressed in the course of mastication, those observed just before swallowing seem to be involved in swallowing initiation. They can be considered as strong candidates for sensory inputs from the bolus that are probably crucially involved in the triggering of

  14. Lingual thyroid and its management II edition

    OpenAIRE

    Balasubramanian, Thiagarajan

    2012-01-01

    This e book discusses lingual thyroid, its etiopathogenesis and management with specific reference to different surgical approaches available. This record was migrated from the OpenDepot repository service in June, 2017 before shutting down.

  15. Comparison of speech performance in labial and lingual orthodontic patients: A prospective study

    Science.gov (United States)

    Rai, Ambesh Kumar; Rozario, Joe E.; Ganeshkar, Sanjay V.

    2014-01-01

    Background: The intensity and duration of speech difficulty inherently associated with lingual therapy is a significant issue of concern in orthodontics. This study was designed to evaluate and to compare the duration of changes in speech between labial and lingual orthodontics. Materials and Methods: A prospective longitudinal clinical study was designed to assess speech of 24 patients undergoing labial or lingual orthodontic treatment. An objective spectrographic evaluation of/s/sound was done using software PRAAT version 5.0.47, a semiobjective auditive evaluation of articulation was done by four speech pathologists and a subjective assessment of speech was done by four laypersons. The tests were performed before (T1), within 24 h (T2), after 1 week (T3) and after 1 month (T4) of the start of therapy. The Mann-Whitney U-test for independent samples was used to assess the significance difference between the labial and lingual appliances. A speech alteration with P appliance systems caused a comparable speech difficulty immediately after bonding (T2). Although the speech recovered within a week in the labial group (T3), the lingual group continued to experience discomfort even after a month (T4). PMID:25540661

  16. Modificaciones en la articulación de fones en pacientes con aparato ortodóncico fijo lingual Speech changes in lingual orthodontic appliances patients

    Directory of Open Access Journals (Sweden)

    Pía Villanueva

    2007-12-01

    Full Text Available OBJETIVO: el presente trabajo pretende evaluar el efecto de los aparatos ortodóncicos fijos linguales en la articulación de los fones, en pacientes que hablen español chileno, y la adaptación a estos efectos dentro del primer mes de uso de los aparatos. MÉTODOS: la muestra consistió en 13 pacientes que acudieron para instalación de aparato ortodóncico fijo lingual. Se realizó un examen fonoarticulatorio en condiciones estandarizadas, en 5 momentos diferentes: previo a la instalación de los aparatos fijos (E0, inmediatamente después de realizada esta (E1, a las 24 horas posteriores (E2, a los 7 días (E3 y un mes después de la instalación (E4. Se determinaron los fones afectados en los distintos momentos de examen respecto a la línea base dada por el examen previo, y se analizó su resolución. RESULTADOS: se observaron cambios significativos en el punto de articulación de los fones [d], [s] y [r] Los fones [d] y [s] mostraron una resolución favorable dentro del primer mes de uso de los aparatos. El fone vibrante múltiple [r] no mostró una recuperación de la alteración una vez cumplido un mes de uso de los aparatos ortodóncicos. CONCLUSIONES: la instalación de aparato ortodóncico fijo lingual produce modificaciones en el punto de articulación de los fones consonánticos, las cuales tienden a mejorar dentro del primer mes de uso de los aparatos, con excepción del fone vibrante múltiple [r].PURPOSE: this study evaluated the effect of lingual orthodontics appliances on speech performance in native Chilean spanish speakers, and their adaptation to these effects during the first month. METHODS: phone production was recorded in a standardized test, in 13 patients with lingual orthodontic brackets, in 5 different times: before (E0, immediately after (E1, within 24 hours after (E2, within 7 days after (E3 and 1 month after (E4 the placement of fixed orthodontic lingual appliances, for assessment by speech professionals. RESULTS

  17. Clinical and Phenomenological Characteristics of Patients with Task-Specific Lingual Dystonia: Possible Association with Occupation

    Directory of Open Access Journals (Sweden)

    Kazuya Yoshida

    2017-12-01

    Full Text Available BackgroundLingual dystonia is a subtype of oromandibular dystonia, which is a movement disorder characterized by involuntary sustained or intermittent contraction of the masticatory and/or tongue muscles. Lingual dystonia interferes with important daily activities, such as speaking, chewing, and swallowing, resulting in vocational and social disability.ObjectiveThe aim of this study was to investigate a possible relationship between occupation and the development of lingual dystonia.MethodsPhenomenological and clinical characteristics of 95 patients [53 females (55.8% and 42 males (44.2%, mean age 48.0 years] with task-specific, speech-induced lingual dystonia were analyzed. Structured interviews were carried out to obtain information regarding primary occupation, including overtime work and stress during work. The factors that might have influenced the development of lingual dystonia were estimated using multivariate logistic regression analysis of the 95 patients with lingual dystonia and 95 controls [68 females (71.6% and 27 males (28.4%, mean age 47.2 years] with temporomandibular disorders.ResultsOverall, 84.2% of the patients had regular occupations; 73.8% of the patients with regular occupations reported working overtime more than twice a week, and 63.8% of them experienced stress at the workplace. Furthermore, 82.1% of the patients had engaged in occupations that required them to talk to customers or other people under stressful situations over prolonged periods of time for many years (mean: 15.6 years. The most common occupation was sales representative (17.9%, followed by telephone operator (13.7%, customer service representative (10.5%, health care worker (9.5%, waiter or waitress (5.3%, receptionist (5.3%, and cashier (5.3%. Twenty-nine patients (30.5% had tardive lingual dystonia. Logistic regression analyses revealed that frequent requirements for professional speaking (p = 0.011, odds ratio: 5.66, high stress during work

  18. Bolus obstruction by Ascaris lumbricoides | Wynne | South African ...

    African Journals Online (AJOL)

    Bolus obstruction by Ascaris lumbricoides. J.M. Wynne, B.A.H. Ellman. Abstract. Seventy-three cases of obstruction due to a bolus of Ascaris worms are reviewed, The diagnosis was made on the basis either of a characteristic palpable mass or a characteristic radiographic appearance. In 67 cases conservative treatment ...

  19. Influence of lingual bracket position on microbial and periodontal parameters in vivo

    Directory of Open Access Journals (Sweden)

    Maria Francesca Sfondrini

    2012-06-01

    Full Text Available OBJECTIVE: Lingual orthodontics is becoming more popular in dental practice. The purpose of the present investigation was to compare plaque formation on teeth bonded with the same bracket onto buccal or lingual surface, with non-bonded control teeth, via an in vivo growth experiment over a 30-day period. MATERIAL AND METHODS: A randomized controlled trial with split-mouth design was set up enrolling 20 dental students. Within each subject sites with buccal and lingual brackets and control sites were followed. Clinical periodontal parameters (periodontal pocket depth: PPD; bleeding on probing: BOP were recorded at baseline and on days 1, 7 and 30. Microbiological samples were taken from the brackets and the teeth on days 1, 7 and 30 to detect colony-forming units (CFU. Total CFU, streptococci CFU and anaerobe CFU were measured. RESULTS: No significant differences (P>0.05 were found between buccal and lingual brackets in terms of clinical periodontal parameters and microbiological values. Conclusion: Bracket position does not have significant impact on bacterial load and on periodontal parameters.

  20. Solid bolus swallowing in the radiologic evaluation of dysphagia

    International Nuclear Information System (INIS)

    Westen, D. van; Ekberg, O.

    1993-01-01

    Patients with dysphagia, heartburn and chest pain are regularly referred for radiologic evaluation of swallowing. The liquid barium swallow has been of great value for the biphasic evaluation of the pharynx and esophagus. Though many patients complain of dysphagia specifically for solids, solid bolus swallow is ususally not part of the evaluation. For the present study we therefore included the use of a solid bolus with a diameter of 13 mm and interviewed the patients carefully for any symptoms during this tablet swallow. Of 200 patients examined, the tablet passed through the esophagus without delay in 102. In the 98 patients with delayed passage, the solid bolus arrest occurred in the pharynx in 5 and in the esophagus in 93. Arrest in the esophagus was due to esophageal dysmotility in 48 patients. Twenty of these were symptomatic during the tablet swallow. A narrowing was the cause in 45, of whom 9 had symptoms. In 18 patients (9%) the solid bolus added key information to the radiologic evaluation. We therefore recommend that the solid bolus is included in the routine radiologic work-up of patients with dysphagia. Careful attention to symptoms during the tablet swallow is important. (orig.)

  1. Solid bolus swallowing in the radiologic evaluation of dysphagia

    Energy Technology Data Exchange (ETDEWEB)

    Westen, D. van (Dept. of Diagnostic Radiology, Malmoe General Hospital, Univ. Lund (Sweden)); Ekberg, O. (Dept. of Diagnostic Radiology, Malmoe General Hospital, Univ. Lund (Sweden))

    1993-07-01

    Patients with dysphagia, heartburn and chest pain are regularly referred for radiologic evaluation of swallowing. The liquid barium swallow has been of great value for the biphasic evaluation of the pharynx and esophagus. Though many patients complain of dysphagia specifically for solids, solid bolus swallow is ususally not part of the evaluation. For the present study we therefore included the use of a solid bolus with a diameter of 13 mm and interviewed the patients carefully for any symptoms during this tablet swallow. Of 200 patients examined, the tablet passed through the esophagus without delay in 102. In the 98 patients with delayed passage, the solid bolus arrest occurred in the pharynx in 5 and in the esophagus in 93. Arrest in the esophagus was due to esophageal dysmotility in 48 patients. Twenty of these were symptomatic during the tablet swallow. A narrowing was the cause in 45, of whom 9 had symptoms. In 18 patients (9%) the solid bolus added key information to the radiologic evaluation. We therefore recommend that the solid bolus is included in the routine radiologic work-up of patients with dysphagia. Careful attention to symptoms during the tablet swallow is important. (orig.).

  2. Safety and efficacy of Bolus administration of magnesium sulphate ...

    African Journals Online (AJOL)

    Safety and efficacy of Bolus administration of magnesium sulphate for preeclampsia. ... On-going research is addressing its administration in terms of dosage, duration and safety. Objective: We evaluated a ... Keywords: safety, efficacy, bolus magnesium sulphate, preeclampsia, University of Benin Teaching Hospital

  3. Computer tomography valorization of the vascular lingual channels in the jaw

    International Nuclear Information System (INIS)

    Costantino, Sebastian; Capiel, Carlos h; Bouzas, Carlos; Vuotto, Miguel; Ferrari, Daniela; Bazzano, Sebastian

    2006-01-01

    Purpose: To determine the frequency, location and position of vascular lingual channels of jaw by dental CT and classifying them based on its location. Material and methods: Dental CT of 100 consecutive patients were reevaluated as previous evaluation to the positioning of dental implants. They are classified by linking their location on the jaw with the number of tooth present or absent in that area. Results: All patients had at least one lingual vascular channel in the jaw; 36 patients presented two channels, eight patients presented three and a patient presented four. The more frequent location was between the sectors of the pieces 31 and 41. Sixteen patients showed two channels (superior and inferior) in that location. The second location by frequency was between pieces 32 and 33 (nine patients). The average distance between the lingual surface of the alveolar rim and the vascular channels was of 16 mm. Conclusion: the dental CT is an excellent method for the identification of the vascular lingual channels by its multiplanar capacity and appropriate image resolution. The characterization and classification of these conduits by a method of easy reading for the radiologists and the dentists assure a correct pre surgical valuation avoiding hemorrhages during the jaw perforation in the positioning of dental implants. (author) [es

  4. Long-term effectiveness of canine-to-canine bonded flexible spiral wire lingual retainers

    NARCIS (Netherlands)

    Renkema, Anne-Marie; Renkema, Alianne; Bronkhorst, Ewald; Katsaros, Christos

    Introduction: The flexible spiral wire (FSW) canine-to-canine lingual retainer bonded to all 6 anterior teeth is a frequently used type of mandibular fixed retainer. This study aimed to assess the long-term effectiveness of FSW canine-to-canine lingual retainers in maintaining the alignment of the

  5. Long-term effectiveness of canine-to-canine bonded flexible spiral wire lingual retainers

    NARCIS (Netherlands)

    Renkema, A.M.; Bronkhorst, E.M.; Katsaros, C.

    2011-01-01

    INTRODUCTION: The flexible spiral wire (FSW) canine-to-canine lingual retainer bonded to all 6 anterior teeth is a frequently used type of mandibular fixed retainer. This study aimed to assess the long-term effectiveness of FSW canine-to-canine lingual retainers in maintaining the alignment of the

  6. Lingual thyroid causing dysphonia: case report

    Directory of Open Access Journals (Sweden)

    Alfio José Tincani

    Full Text Available CONTEXT: Lingual thyroid gland is a rare clinical entity that is caused by the failure of the thyroid gland to descend to a normal cervical location during embryogenesis. The occurrence of an ectopic thyroid gland located at the base of the tongue may cause problems for the patient, with symptoms of dysphagia, dysphonia, upper airway obstruction or even hemorrhage at any time from infancy through adulthood. CASE REPORT: We report on a case of lingual thyroid gland in a 41-year-old female patient. The embryology and diagnosis of ectopic thyroid are discussed and its management is outlined. Features of the diagnostic and therapeutic evaluation are described with attention to the clinical findings, laboratory tests, thyroid scan and computed tomography imaging studies employed in the confirmation of diagnosis and planning of appropriate treatment. The history of the condition is reviewed and a treatment strategy is outlined. Surgical excision of the gland is reserved for cases of gland enlargement that result in compromised airways (dysphagia or dysphonia or recurrent hemorrhage.

  7. Three case reports demonstrating treatment of relatively complex orthodontic cases using a completely customised lingual appliance.

    Science.gov (United States)

    Buckley, John

    2016-01-01

    It is a commonly held misconception among Irish dentists that only minor malocclusions can be treated with lingual appliances. This article demonstrates the use of contemporary completely customised lingual orthodontic appliances to treat a diverse range of malocclusions, to a satisfactory level, and thereby may disabuse clinicians of the belief that only minor malocclusions can be treated with lingual appliances.

  8. Accelerated aging effects on surface hardness and roughness of lingual retainer adhesives.

    Science.gov (United States)

    Ramoglu, Sabri Ilhan; Usumez, Serdar; Buyukyilmaz, Tamer

    2008-01-01

    To test the null hypothesis that accelerated aging has no effect on the surface microhardness and roughness of two light-cured lingual retainer adhesives. Ten samples of light-cured materials, Transbond Lingual Retainer (3M Unitek) and Light Cure Retainer (Reliance) were cured with a halogen light for 40 seconds. Vickers hardness and surface roughness were measured before and after accelerated aging of 300 hours in a weathering tester. Differences between mean values were analyzed for statistical significance using a t-test. The level of statistical significance was set at P statistically significant (P statistically significant (P .05). Accelerated aging significantly increased the surface microhardness of both light-cured retainer adhesives tested. It also significantly increased the surface roughness of the Transbond Lingual Retainer.

  9. Morphofunctional structure of the lingual papillae in three species of South American Camelids: Alpaca, guanaco, and llama.

    Science.gov (United States)

    Erdoğan, Serkan; Villar Arias, Silvia; Pérez, William

    2016-02-01

    The aim of this study was to compare the anatomical and functional characteristics of the lingual papilla among the Camelidae. For this purpose, tongues of alpaca, guanaco, and llama were used. Numerous long and thin filiform papillae were located in the median groove and none were detected on the rest of the dorsal surface of the lingual apex in alpaca. Secondary papillae originated from the base of some filiform papillae on the ventral surface of alpaca tongue. The bases of some filiform papillae of the lateral surface of the lingual apex were inserted into conspicuous grooves in guanaco and tips of filiform papillae on the dorsal surface of the lingual body were ended by bifurcated apex. On the dorsal surface of the lingual apex of llama, there were no filiform papillae but there were numerous filiform papillae on both the lateral margins of the ventral surface of the lingual apex. Fungiform papillae were distributed randomly on dorsal lingual surface and ventral margins of the tongues of all camelid species. Lenticular papillae were located on the lingual torus and varied in size and topographical distribution for each species. Circumvallate papillae had irregular surfaces in llama and alpaca, and smooth surface in guanaco. In conclusion, llama and alpaca tongues were more similar to each other, and tongues of all camelid species displayed more similarities to those of Bactrian and dromedary camels in comparison with other herbivores and ruminants. © 2015 Wiley Periodicals, Inc.

  10. Association between swallow perception and esophageal bolus clearance in patients with globus sensation.

    Science.gov (United States)

    Chen, Chien-Lin; Yi, Chih-Hsun; Liu, Tso-Tsai

    2013-04-01

    Globus sensation is common, but its pathogenesis is not yet clear. Our purpose was to investigate subjective perception of swallowing and esophageal motility by combined multichannel intraluminal impedance and manometry (MII-EM) for patients with globus sensation. Combined MII-EM was performed for 25 globus patients and 15 healthy controls. Swallows were abnormal if hypocontractivity or simultaneous contractions occurred. Esophageal bolus transit was incomplete if bolus exit was not found at one or more of all measurement sites. Perception of each swallow was assessed by use of a standardized scoring system, and was enhanced if the score was >1. Few globus patients reported enhanced perception during viscous or solid swallows. Incomplete bolus transit and enhanced perception occurred similarly between viscous and solid boluses. Agreement between enhanced perception and proximal bolus clearance was greater during solid swallows (κ = 0.45, 95 % CI: 0.32-0.58) than during viscous swallows (κ = 0.13, 95 % CI: 0-0.25) (P perception and total bolus clearance was greater during solid swallows (κ = 0.46, 95 % CI: 0.34-0.58) than during viscous swallows (κ = 0.11, 95 % CI: 0-0.22) (P perception is uncommon in patients with globus sensation, although there is a significant association between enhanced esophageal perception and solid bolus clearance. Application of a solid bolus may help better delineation of the interrelationship between the subjective perception of bolus passage and the objective measurement of bolus clearance.

  11. Hashimoto's Thyroiditis: Lingual and Labial Capillary Microcirculation in Patients Affected by Macroglossia

    OpenAIRE

    Scardina, G. A.; Messina, P.

    2007-01-01

    The aim of this study is to estudy lingual and labial microcirculation differences among healthy subjects and those with Hashimoto's thyroiditis affected by macroglossia. Twenty healthy patients and 20 patients suffering from Hashimoto's thyroiditis were examined. Labial and lingual capiUaroscopy were used to investigate the characteristics of microcirculation. For each patient we evaluated visibility, course, tortuosity and the possible presence of microhaemorrhages, average calibre of capil...

  12. Effect of intrusive and retraction forces in labial and lingual orthodontics: A finite element study

    Directory of Open Access Journals (Sweden)

    Rohan Mascarenhas

    2014-01-01

    Full Text Available Objectives: Lingual orthodontics differs in biomechanics as compared to labial system and has biomechanical advantages. Although theoretical approaches have explained the differences between labial and lingual orthodontics, the finite element method (FEM may be better suited to analyze these differences. This study analyzes the effect of vertical and horizontal forces together on the tooth using FEM. Materials and Methods: An extracted right maxillary central incisor was radiographed and was used to create a solid model using ANSYS. The geometric model was converted into a finite element model with the help of ANSYS software. The model consists of 27,000 elements and 30,000 nodes. Two force vectors (vertical and horizontal were applied labially and lingually at 3 different heights- 4 mm, 5 mm and 6 mm from the incisal edge. Results: In the labial system, the net force vector passes through the center of resistance (CR and brings about intrusion. The net force vector in lingual orthodontics does not pass through the center of resistance and produces lingual tipping of the incisors. Conclusion: Intrusion and retraction forces bring about tipping of incisors in lingual orthodontics. The same amount of intrusion and retraction forces brings about intrusion of incisors in labial orthodontics. Therefore, direction and amount of forces should be carefully and judiciously applied after taking into consideration the resultant biomechanical differences.

  13. Fat digestion by lingual lipase: mechanism of lipolysis in the stomach and upper small intestine.

    Science.gov (United States)

    Liao, T H; Hamosh, P; Hamosh, M

    1984-05-01

    Ten to 30% of dietary fat is hydrolyzed in the stomach by lingual lipase, an enzyme secreted from lingual serous glands. We investigated the substrate specificity of this enzyme as well as the potential of lingual lipase to act in the upper small intestine i.e., in the presence of bile salts and lecithin. The data presented show that partially purified preparations of rat lingual lipase and the lipase in gastric aspirates of newborn infants have identical substrate specificity: medium-chain triglycerides were hydrolyzed at rates 5-8-fold higher than long-chain triglycerides; the rat and human enzymes do not hydrolyze the ester bond of lecithin or cholesteryl-ester. In contrast to pancreatic lipase, the hydrolysis of triglycerides by lingual lipase is not inhibited by lecithin. But, similar to pancreatic lipase the activity of lingual lipase is inhibited by bile salts, the extent of inhibition varying with its nature and concentration. This inactivation is not prevented by colipase but is partially averted by lipids and protein, suggesting that lingual lipase can remain active in the duodenum. The pH optimum of the enzyme (2.2-6.5 in the rat and 3.5-6.0 in human gastric aspirates) is compatible with continued activity in the upper small intestine, especially during the neonatal period, when the luminal pH is under 6.5. The marked variation in lipase activity levels in gastric aspirates of newborn infants is probably due to individual variations in enzyme amounts. The characteristics of the lipase are however identical in infants with low, intermediate or high activity levels.(ABSTRACT TRUNCATED AT 250 WORDS)

  14. Morphology of the tongue and characteristics of lingual papillae in Cuniculus paca (Rodentia: Cuniculidae

    Directory of Open Access Journals (Sweden)

    André Luiz Quagliatto Santos

    2013-11-01

    Full Text Available This paper describes the morphology of the tongue, its extrinsic muscles, and the characteristics of lingual papillae in Cuniculus paca. We used fifteen specimens from the Wild Animals Sector of Universidade Estadual Paulista (UNESP. In this species, the tongue is divided into three regions: root, body, and apex. The latter is delimited by the lingual frenum, which has the aspect of fibrous membrane. We also identified a median groove and a prominence on its dorsal surface. The extrinsic tongue muscles are the styloglossus, hyoglossus, genioglossus, geniohyoid, and milohyoid, the latter two are inserted into the hyoid apparatus. As for the presence of lingual papillae, we observed five papillae types in all specimens: filiform, fungiform, vallate, foliate, and conic. The filiform papillae are distributed throughout the apex surface and tongue body. They are caudally inclined throughout the body, until they are modified in the root region and form the conic papillae. The fungiform papillae are distributed in a large amount on the lingual apex, between the filiform papillae. This papilla type has a mushroom-like shape. Only two vallate papillae are located in the caudal portion of the lingual root, and they have an oval shape and are surrounded by a deep groove. The foliate papillae are observed in parallel grooves or slots located in the lateral portion of the tongue, between the vallate papillae and half of the intermolar prominence. In the tongue root, body, and apex we observed keratinized squamous stratified epithelium lining both the lingual papillae and the surface between them.

  15. Orthodontic Metallic Lingual Brackets: The Dark Side of the Moon of Bond Failures?

    Directory of Open Access Journals (Sweden)

    Maria Francesca Sfondrini

    2017-07-01

    Full Text Available Lingual orthodontics, among both young and adult patients, increased in popularity during last years. The purposes of the present investigation were to evaluate the shear bond strength (SBS values and Adhesive Remnant Index (ARI scores of different lingual brackets compared with a vestibular control bracket. One hundred bovine teeth were extracted and embedded in resin blocks. Four different lingual brackets (Idea, Leone; STB, Ormco; TTR, RMO; 2D, Forestadent and a vestibular control bracket (Victory, 3M were bonded to the bovine enamel surfaces and subsequently shear tested to failure utilizing a Universal Testing Machine. SBS values were measured. A microscopic evaluation was performed to obtain ARI scores. Statistical analysis was performed at a statistically significant level of p < 0.05 to determine significant differences in SBS values and ARI Scores. No statistically significant variations in SBS were reported among the different groups. Conversely, significant differences were shown in ARI scores among the various groups. Clinical relevance of the present study is that orthodontists can expect similar resistance to debonding forces from lingual appliances as with vestibular brackets.

  16. Bolus obstruction by Ascaris lumbricoides

    African Journals Online (AJOL)

    In 67 cases conservative treatment was successful. ... bolus of worms, biliary ascariasis,3.6 pancreatitis and acute ... or chronic granulomatous peritonitis is rare.i These complica- ... obstruction admitted to the paediatric surgical wards of the.

  17. Lingual vs. labial fixed orthodontic appliances: systematic review and meta-analysis of treatment effects.

    Science.gov (United States)

    Papageorgiou, Spyridon N; Gölz, Lina; Jäger, Andreas; Eliades, Theodore; Bourauel, Christoph

    2016-04-01

    The aim of this systematic review was to compare the therapeutic and adverse effects of lingual and labial orthodontic fixed appliances from clinical trials on human patients in an evidence-based manner. Randomized and prospective non-randomized clinical trials comparing lingual and labial appliances were included. Risk of bias within and across studies was assessed using the Cochrane tool and the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach. Random-effects meta-analyses were conducted, followed by subgroup and sensitivity analyses. Six electronic databases were searched from inception to July 2015, without limitations. A total of 13 papers pertaining to 11 clinical trials were included with a total of 407 (34% male/66% female) patients. Compared with labial appliances, lingual appliances were associated with increased overall oral discomfort, increased speech impediment (measured using auditory analysis), worse speech performance assessed by laypersons, increased eating difficulty, and decreased intermolar width. On the other hand, lingual appliances were associated with increased intercanine width and significantly decreased anchorage loss of the maxillary first molar during space closure. Based on existing trials, there is insufficient evidence to make robust recommendations for lingual fixed orthodontic appliances regarding their therapeutic or adverse effects, as the quality of evidence was low. © 2016 Eur J Oral Sci.

  18. Efficacy of a Targeted Drug Delivery on-Demand Bolus Option for Chronic Pain.

    Science.gov (United States)

    Bolash, Robert B; Niazi, Tariq; Kumari, Meera; Azer, Gerges; Mekhail, Nagy

    2018-03-01

    Intrathecal targeted drug delivery systems historically required physician office visits for dose adjustment to manage fluctuating pain. A wireless device now enables patients to supplement their basal intrathecal infusion with a programmed on-demand bolus dose. We sought to quantify the change in oral breakthrough opioid need associated with the use of an intrathecal bolus in comparison to those treated with the basal infusion alone. Demographic, dosage, bolus usage and longevity data were extracted from the historical medical record of 69 patients (18/51 bolus/nonbolus) followed continuously at our center. Medication consumption and Pain Disability Index measures were obtained at baseline and most recent follow-up. Among patients with the bolus option, only 2 (11%; confidence interval [CI] 0% to 26%) continued to require oral opiates to manage breakthrough pain compared to 29 (57%; CI 43% to 71%) without the bolus option. The Pain Disability Index score decreased by 19% in patients with the bolus option and by 25% in those with the basal infusion. Total daily intrathecal opioid intake was 34% lower in the group with the bolus device. Utilizing an intrathecal bolus to treat incident pain was a safe way to manage unpredictable breakthrough pain and may represent a cost-saving opportunity by eliminating the need for oral analgesic medications. © 2017 World Institute of Pain.

  19. The predictive ability of six pharmacokinetic models of rocuronium developed using a single bolus: evaluation with bolus and continuous infusion regimen.

    Science.gov (United States)

    Sasakawa, Tomoki; Masui, Kenichi; Kazama, Tomiei; Iwasaki, Hiroshi

    2016-08-01

    Rocuronium concentration prediction using pharmacokinetic (PK) models would be useful for controlling rocuronium effects because neuromuscular monitoring throughout anesthesia can be difficult. This study assessed whether six different compartmental PK models developed from data obtained after bolus administration only could predict the measured plasma concentration (Cp) values of rocuronium delivered by bolus followed by continuous infusion. Rocuronium Cp values from 19 healthy subjects who received a bolus dose followed by continuous infusion in a phase III multicenter trial in Japan were used retrospectively as evaluation datasets. Six different compartmental PK models of rocuronium were used to simulate rocuronium Cp time course values, which were compared with measured Cp values. Prediction error (PE) derivatives of median absolute PE (MDAPE), median PE (MDPE), wobble, divergence absolute PE, and divergence PE were used to assess inaccuracy, bias, intra-individual variability, and time-related trends in APE and PE values. MDAPE and MDPE values were acceptable only for the Magorian and Kleijn models. The divergence PE value for the Kleijn model was lower than -10 %/h, indicating unstable prediction over time. The Szenohradszky model had the lowest divergence PE (-2.7 %/h) and wobble (5.4 %) values with negative bias (MDPE = -25.9 %). These three models were developed using the mixed-effects modeling approach. The Magorian model showed the best PE derivatives among the models assessed. A PK model developed from data obtained after single-bolus dosing can predict Cp values during bolus and continuous infusion. Thus, a mixed-effects modeling approach may be preferable in extrapolating such data.

  20. Chemistry and propulsion; Chimie et propulsions

    Energy Technology Data Exchange (ETDEWEB)

    Potier, P [Maison de la Chimie, 75 - Paris (France); Davenas, A [societe Nationale des Poudres et des Explosifs - SNPE (France); Berman, M [Air Force Office of Scientific Research, Arlington, VA (United States); and others

    2002-07-01

    During the colloquium on chemistry and propulsion, held in march 2002, ten papers have been presented. The proceedings are brought in this document: ramjet, scram-jet and Pulse Detonation Engine; researches and applications on energetic materials and propulsion; advances in poly-nitrogen chemistry; evolution of space propulsion; environmental and technological stakes of aeronautic propulsion; ramjet engines and pulse detonation engines, automobiles thermal engines for 2015, high temperature fuel cells for the propulsion domain, the hydrogen and the fuel cells in the future transports. (A.L.B.)

  1. An Adaptive Nonlinear Basal-Bolus Calculator for Patients With Type 1 Diabetes

    DEFF Research Database (Denmark)

    Boiroux, Dimitri; Aradóttir, Tinna Björk; Nørgaard, Kirsten

    2017-01-01

    size. Following meal announcements, the meal compartment and the meal time constant are estimated, otherwise insulin sensitivity is estimated. Results : We compare the performance of a conventional linear bolus calculator with the proposed bolus calculator. The proposed basal-bolus calculator......Background : Bolus calculators help patients with type 1 diabetes to mitigate the effect of meals on their blood glucose by administering a large amount of insulin at mealtime. Intraindividual changes in patients physiology and nonlinearity in insulin-glucose dynamics pose a challenge...... glucose monitor (CGM). The basal rate is determined by calculating the steady state of the model and is adjusted once a day before breakfast. The bolus size is determined by optimizing the postprandial glucose values based on an estimate of the insulin sensitivity and states, as well as the announced meal...

  2. The influence of a solid and liquid bolus on food-stimulated gastroesophageal reflux

    Energy Technology Data Exchange (ETDEWEB)

    Naeser, A.; Behrens, J.K.; Vejen-Christiansen, L.; Funch-Jensen, P.; Thommesen, P. (Aarhus Kommunehospital (Denmark). GI Motility Lab. Aarhus Kommunehospital (Denmark). Dept. of Diagnostic Radiology R)

    1992-02-01

    Using a radiological method to demonstrate food-stimulated gastroesophageal reflux (GER), a comparative study was carried out employing a solid, already validated bolus versus a liquid one. One hundred and four consecutive patients received both a solid and a liquid bolus in randomized order. GER was observed in 37 (35.6%) patients receiving the solid bolus versus 28 (26.9%) with the liquid one. This means that the solid bolus provokes significantly more reflux (P<0.02). GER, grade II (reflux above the level of the carina), occurred equally often as a result of both types of bolus, however. The study suggests that significant, food-stimulated GER is independent of the consistency of the foodstuffs and may be detected employing a liquid bolus. This result might be used in the examination of infants for GER, using milk as a food stimulus. (orig.).

  3. Airway evaluation by indirect laryngoscopy in patients with lingual tonsillar hypertrophy.

    Science.gov (United States)

    Sánchez-Morillo, Jorge; Gómez-Diago, Lorena; Rodríguez-Gimillo, Pablo; Herrera-Collado, Raúl; Puchol-Castillo, Jorge; Mompó-Romero, Luis

    2013-01-01

    Prevalence of the lingual tonsillar hypertrophy is unknown but it is believed that its presence is associated with the difficult airway. To investigate this, indirect laryngoscopy was performed on patients in the preoperative evaluation and this pathology was diagnosed. The relationship with difficulty of viewing the larynx, intubation and ventilation, under general anaesthesia and using direct laryngoscopy, was then studied. We performed the demographic variable checks and tests for predicting difficult intubation (mouth opening, thyromental distance, cervical flexion-extension, neck thickness and Mallampati test), in the preoperative step on 300 patients who were going to be submitted to general anaesthesia. We then performed indirect laryngoscopy on them using a 70° rigid laryngoscope to ascertain the frequency of appearance of lingual tonsillar hypertrophy. Next, under general anaesthesia, we carried out direct laryngoscopy to verify whether there was difficulty in viewing the larynx and intubation and ventilation. We then investigated the association of demographic predictors of difficult intubation, including indirect laryngoscopy, with the presence of this condition. Prevalence of lingual tonsillar hypertrophy was 2%. No relationship between the appearance of this entity and the difficulty of viewing the larynx, intubation and ventilation was found. Only indirect laryngoscopy was linked to the appearance of this pathology. Lingual tonsillar hypertrophy is a relatively frequent disorder, whose presence is not usually associated with difficult airway. Copyright © 2012 Elsevier España, S.L. All rights reserved.

  4. The influence of a solid and liquid bolus on food-stimulated gastroesophageal reflux

    International Nuclear Information System (INIS)

    Naeser, A.; Behrens, J.K.; Vejen-Christiansen, L.; Funch-Jensen, P.; Thommesen, P.; Aarhus Kommunehospital

    1992-01-01

    Using a radiological method to demonstrate food-stimulated gastroesophageal reflux (GER), a comparative study was carried out employing a solid, already validated bolus versus a liquid one. One hundred and four consecutive patients received both a solid and a liquid bolus in randomized order. GER was observed in 37 (35.6%) patients receiving the solid bolus versus 28 (26.9%) with the liquid one. This means that the solid bolus provokes significantly more reflux (P [de

  5. MO-H-19A-03: Patient Specific Bolus with 3D Printing Technology for Electron Radiotherapy

    International Nuclear Information System (INIS)

    Zou, W; Swann, B; Siderits, R; McKenna, M; Khan, A; Yue, N; Zhang, M; Fisher, T

    2014-01-01

    Purpose: Bolus is widely used in electron radiotherapy to achieve desired dose distribution. 3D printing technologies provide clinicians with easy access to fabricate patient specific bolus accommodating patient body surface irregularities and tissue inhomogeneity. This study presents the design and the clinical workflow of 3D printed bolus for patient electron therapy in our clinic. Methods: Patient simulation CT images free of bolus were exported from treatment planning system (TPS) to an in-house developed software package. Bolus with known material properties was designed in the software package and then exported back to the TPS as a structure. Dose calculation was carried out to examine the coverage of the target. After satisfying dose distribution was achieved, the bolus structure was transferred in Standard Tessellation Language (STL) file format for the 3D printer to generate the machine codes for printing. Upon receiving printed bolus, a quick quality assurance was performed with patient resimulated with bolus in place to verify the bolus dosimetric property before treatment started. Results: A patient specific bolus for electron radiotherapy was designed and fabricated in Form 1 3D printer with methacrylate photopolymer resin. Satisfying dose distribution was achieved in patient with bolus setup. Treatment was successfully finished for one patient with the 3D printed bolus. Conclusion: The electron bolus fabrication with 3D printing technology was successfully implemented in clinic practice

  6. MO-H-19A-03: Patient Specific Bolus with 3D Printing Technology for Electron Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Zou, W; Swann, B; Siderits, R; McKenna, M; Khan, A; Yue, N; Zhang, M [Rutgers University, New Brunswick, NJ (United States); Fisher, T [Memorial Medical Center, Modesto, CA (United States)

    2014-06-15

    Purpose: Bolus is widely used in electron radiotherapy to achieve desired dose distribution. 3D printing technologies provide clinicians with easy access to fabricate patient specific bolus accommodating patient body surface irregularities and tissue inhomogeneity. This study presents the design and the clinical workflow of 3D printed bolus for patient electron therapy in our clinic. Methods: Patient simulation CT images free of bolus were exported from treatment planning system (TPS) to an in-house developed software package. Bolus with known material properties was designed in the software package and then exported back to the TPS as a structure. Dose calculation was carried out to examine the coverage of the target. After satisfying dose distribution was achieved, the bolus structure was transferred in Standard Tessellation Language (STL) file format for the 3D printer to generate the machine codes for printing. Upon receiving printed bolus, a quick quality assurance was performed with patient resimulated with bolus in place to verify the bolus dosimetric property before treatment started. Results: A patient specific bolus for electron radiotherapy was designed and fabricated in Form 1 3D printer with methacrylate photopolymer resin. Satisfying dose distribution was achieved in patient with bolus setup. Treatment was successfully finished for one patient with the 3D printed bolus. Conclusion: The electron bolus fabrication with 3D printing technology was successfully implemented in clinic practice.

  7. Cross-Lingual Dependency Parsing with Late Decoding for Truly Low-Resource Languages

    OpenAIRE

    Schlichtkrull, Michael Sejr; Søgaard, Anders

    2017-01-01

    In cross-lingual dependency annotation projection, information is often lost during transfer because of early decoding. We present an end-to-end graph-based neural network dependency parser that can be trained to reproduce matrices of edge scores, which can be directly projected across word alignments. We show that our approach to cross-lingual dependency parsing is not only simpler, but also achieves an absolute improvement of 2.25% averaged across 10 languages compared to the previous state...

  8. Comparative evaluation of sagittal anchorage loss in lingual and labial appliances during space closure: A pilot study

    Directory of Open Access Journals (Sweden)

    Shivanand Venkatesh

    2015-01-01

    Full Text Available Aim: The purpose of this investigation was to assess and compare the anchorage loss between labial and lingual appliance systems during space closure. Materials and Methods: Twenty subjects were part of the study among which 10 subjects (mean age 21 ± 3.6 years were treated using lingual appliance system (0.018" slot-STb™ and 10 subjects (mean age 19 ± 6.1 years were treated using labial preadjusted edgewise appliance system (0.018" slot-MBT™ . First premolar extractions were performed to enable retraction of anterior teeth. Lateral cephalometric radiographs were taken at two intervals, before starting space closure and after space closure that were connoted as T0 and T1 and were analyzed using the method described by Pancherz to measure anchorage loss. Intraclass correlation coefficient (ICC was used to evaluate intraexaminer reliability of the measurements. Student′s t-test was performed to verify any statistical significant correlation between the labial and lingual appliance systems. Statistical differences were determined at the 95% confidence level (P < 0.05. Results: The results showed that all ICC for lingual and labial group were ≥0.90 showing good repeatability of the measurements. Mean anchorage loss of 1.238 ± 0.17 mm in lingual appliance system and an anchorage loss of 2.06 ± 0.39 mm occurred with the labial appliance system. On the comparison between the two appliance systems, lingual appliance demonstrated a significantly lesser anchorage loss than did the labial appliance. Interpretation and Conclusion: This prospective study concludes with the fact that lingual appliance provided better anchorage control than labial appliance during space closure. Use of lingual appliance could be considered in critical anchorage cases when compared with labial appliance.

  9. Serum levels of bupivacaine after pre-peritoneal bolus vs. epidural bolus injection for analgesia in abdominal surgery: A safety study within a randomized controlled trial.

    Science.gov (United States)

    Mungroop, Timothy H; van Samkar, Ganapathy; Geerts, Bart F; van Dieren, Susan; Besselink, Marc G; Veelo, Denise P; Lirk, Philipp

    2017-01-01

    Continuous wound infiltration (CWI) has become increasingly popular in recent years as an alternative to epidural analgesia. As catheters are not placed until the end of surgery, more intraoperative opioid analgesics might be needed. We, therefore, added a single pre-peritoneal bolus of bupivacaine at the start of laparotomy, similar to the bolus given with epidural analgesia. This was a comparative study within a randomized controlled trial (NTR4948). Patients undergoing hepato-pancreato-biliary surgery received either a pre-peritoneal bolus of 30ml bupivacaine 0.25%, or an epidural bolus of 10ml bupivacaine 0.25% at the start of laparotomy. In a subgroup of patients, we sampled blood and determined bupivacaine serum levels 20, 40, 60 and 80 minutes after bolus injection. We assumed toxicity of bupivacaine to be >1000 ng/ml. A total of 20 patients participated in this sub-study. All plasma levels measured as well as the upper limit of the predicted 99% confidence intervals per time point were well below the toxicity limit. In a mixed linear-effect model both groups did not differ statistically significant (p = 0.131). The intra-operative use of opioids was higher with CWI as compared to epidural (86 (SD 73) μg sufentanil vs. 50 (SD 32). In this exploratory study, the pre-peritoneal bolus using bupivacaine resulted in serum bupivacaine concentrations well below the commonly accepted toxic threshold. With CWI more additional analgesics are needed intraoperatively as compared to epidural analgesia, although this is compensated by a reduction in use of vasopressors with CWI. Netherlands Trial Register NTR4948.

  10. Morphology of the dorsal lingual papillae in the newborn panther and Asian black bear.

    Science.gov (United States)

    Emura, S; Hayakawa, D; Chen, H; Shoumura, S

    2001-12-01

    The dorsal lingual surfaces of a newborn panther (Panthera pardus) and two newborn asian black bears (Selenarctos thibetanus) were examined by scanning electron microscopy (SEM). The tongues of the panther and asian black bear were about 40 mm in length and about 20 mm in width. Filiform, fungiform and vallate papillae were found. The filiform papillae were distributed over the entire dorsal surface of the tongue. In the panther, the filiform papillae on margin of the lingual apex were divided into two shapes which were horny or club-shaped papillae. The filiform papillae on the midportion were larger than those on the lateral region in size. The fungiform papillae also were divided into two shapes which were hemispherical or club-shaped papillae. In the asian black bear, the filiform papillae on the margin of the lingual apex were larger than those on margin of the panther tongue. The vallate papillae in the animals of two species were located on both sides of the posterior end of the lingual body. Each papilla was surrounded by a groove and crescent pad.

  11. Assessment of myocardial perfusion with MRI using a modified dual bolus method

    International Nuclear Information System (INIS)

    Husso, M; Sipola, P; Manninen, H; Vainio, P; Kuittinen, T; Hartikainen, J; Saarakkala, S; Töyräs, J; Kuikka, J

    2014-01-01

    Quantification of regional myocardial blood flow (rMBF) with first-pass magnetic resonance imaging (FP-MRI) requires two contrast agent injections (dual bolus technique), inducing error in the determined rMBF if the injections differ. We hypothesize that using input and residue curves of the same injection would be more reliable. We aim to introduce and evaluate a novel method to correct the high concentration arterial input function (AIF) for determination of rMBF. Sixteen patients with non-Hodgkin's lymphoma were examined before and after chemotherapy. The input function was solved by correcting initial high concentration AIF using the ratio of low and high contrast AIF areas, normalized by corresponding heart rates (modified dual bolus method). For comparison, the scaled low contrast AIF was used as an input function (dual bolus method). Unidirectional transfer coefficient K trans  was calculated using both methods. K trans -values determined with the dual bolus (0.81 ± 0.32 ml g −1  min −1 ) and modified dual bolus (0.77 ± 0.42 ml g −1  min −1 ) methods were in agreement (p = 0.21). Mean K trans -values increased from 0.76 ± 0.43 to 0.89 ± 0.55 ml g −1  min −1  after chemotherapy (p = 0.17). The modified dual bolus technique agrees with the dual bolus technique (R2 = 0.899) when the low and high contrast injections are similar. However, when this is not the case, the modified dual bolus technique may be more reliable. (paper)

  12. Assessment of bolus transit with intraluminal impedance measurement in patients with esophageal motility disorders.

    Science.gov (United States)

    Bogte, A; Bredenoord, A J; Oors, J; Siersema, P D; Smout, A J P M

    2015-10-01

    The clinical management of patients with non-obstructive dysphagia is notoriously difficult. Esophageal impedance measurement can be used to measure esophageal bolus transit without the use of radiation exposure to patients. However, validation of measurement of bolus transit with impedance monitoring has only been performed in healthy subjects with normal motility and not in patients with dysphagia and esophageal motility disorders. The aim was, therefore, to investigate the relationship between transit of swallowed liquid boluses in healthy controls and in patients with dysphagia. Twenty healthy volunteers and 20 patients with dysphagia underwent concurrent impedance measurement and videofluoroscopy. Each subject swallowed five liquid barium boluses. The ability of detecting complete or incomplete bolus transit by means of impedance measurement was assessed, using radiographic bolus transit as the gold standard. Impedance monitoring recognized stasis and transit in 80.5% of the events correctly, with 83.9% of bolus transit being recognized and 77.2% of stasis being recognized correctly. In controls 79.8% of all swallows were scored correctly, whereas in patients 81.3% of all swallows were scored correctly. Depending on the contractility pattern, between 77.0% and 94.3% of the swallows were scored correctly. Impedance measurement can be used to assess bolus clearance patterns in healthy subjects, but can also be used to reliably assess bolus transit in patients with dysphagia and motility disorders. © 2015 John Wiley & Sons Ltd.

  13. Effect of Bolus Viscosity on the Safety and Efficacy of Swallowing and the Kinematics of the Swallow Response in Patients with Oropharyngeal Dysphagia: White Paper by the European Society for Swallowing Disorders (ESSD).

    Science.gov (United States)

    Newman, Roger; Vilardell, Natàlia; Clavé, Pere; Speyer, Renée

    2016-04-01

    Fluid thickening is a well-established management strategy for oropharyngeal dysphagia (OD). However, the effects of thickening agents on the physiology of impaired swallow responses are not fully understood, and there is no agreement on the degree of bolus thickening. To review the literature and to produce a white paper of the European Society for Swallowing Disorders (ESSD) describing the evidence in the literature on the effect that bolus modification has upon the physiology, efficacy and safety of swallowing in adults with OD. A systematic search was performed using the electronic Pubmed and Embase databases. Articles in English available up to July 2015 were considered. The inclusion criteria swallowing studies on adults over 18 years of age; healthy people or patients with oropharyngeal dysphagia; bolus modification; effects of bolus modification on swallow safety (penetration/aspiration) and efficacy; and/or physiology and original articles written in English. The exclusion criteria consisted of oesophageal dysphagia and conference abstracts or presentations. The quality of the selected papers and the level of research evidence were assessed by standard quality assessments. At the end of the selection process, 33 articles were considered. The quality of all included studies was assessed using systematic, reproducible, and quantitative tools (Kmet and NHMRC) concluding that all the selected articles reached a valid level of evidence. The literature search gathered data from various sources, ranging from double-blind randomised control trials to systematic reviews focused on changes occurring in swallowing physiology caused by thickened fluids. Main results suggest that increasing bolus viscosity (a) results in increased safety of swallowing, (b) also results in increased amounts of oral and/or pharyngeal residue which may result in post-swallow airway invasion, (c) impacts the physiology with increased lingual pressure patterns, no major changes in impaired

  14. Lingual traction to facilitate fiber-optic intubation of difficult airways: a single-anesthesiologist randomized trial.

    Science.gov (United States)

    Ching, Yiu-Hei; Karlnoski, Rachel A; Chen, Henian; Camporesi, Enrico M; Shah, Vimal V; Padhya, Tapan A; Mangar, Devanand

    2015-04-01

    Flexible fiber-optic bronchoscope-guided orotracheal intubation is a valuable technique with demonstrated benefits in the management of difficult airways. Despite its popularity with anesthesia providers, the technique is not fail-safe and airway-related complications secondary to failed intubation attempts remain an important problem. We sought to determine the effect of incorporating lingual traction on the success rate of fiber-optic bronchoscope-guided intubation in patients with anticipated difficult airways. In this prospective, randomized, cohort study, we enrolled 91 adult patients with anticipated difficult airways scheduled for elective surgery to undergo fiber-optic bronchoscope-guided orotracheal intubation alone or with lingual traction by an individual anesthesiologist after induction of general anesthesia and neuromuscular blockade. A total of 78 patients were randomized: 39 patients to the fiber-optic bronchoscope-guided intubation with lingual traction group and 39 patients to the fiber-optic bronchoscope-guided intubation alone group. The primary endpoint was the rate of successful first attempt intubations. The secondary outcome was sore throat grade on post-operative day 1. Fiber-optic intubation with lingual traction compared to fiber-optic intubation alone resulted in a higher success rate (92.3 vs. 74.4 %, χ (2) = 4.523, p = 0.033) and greater odds for successful first attempt intubation (OR 4.138, 95 % CI 1.041-16.444, p = 0.044). Sore throat severity on post-operative day 1 was not significantly different but trended towards worsening grades with lingual traction. In this study, lingual traction was shown to be a valuable maneuver for facilitating fiber-optic bronchoscope-guided intubation in the management of patients with anticipated difficult airways.

  15. Blueprint of a Cross-Lingual Web Retrieval Collection

    NARCIS (Netherlands)

    Sigurbjörnsson, B.; Kamps, J.; de Rijke, M.; van Zwol, R.

    2005-01-01

    The world wide web is a natural setting for cross-lingual information retrieval; web content is essentially multilingual, and web searchers are often polyglots. Even though English has emerged as the lingua franca of the web, planning for a business trip or holiday usually involves digesting pages

  16. Barium and meat. A comparison between pharyngeal swallow of fluid and solid boluses

    Energy Technology Data Exchange (ETDEWEB)

    Ekberg, O.; Liedberg, B.; Oewall, B.

    The influence of bolus consistency on pharyngeal swallow was radiologically studied in 24 individuals by comparing liquid barium and solid meat after chewing. Pharyngeal function was apparently performed synchronously and symmetrically on both boluses. No definite conclusion about the influence on epiglottic mobility, closure of the laryngeal vestibule and relaxation of the circopharyngeal muscle could be drawn from this study. There was no difference in the elevation of the pharynx and larynx. The transit time for a solid bolus was shorter compared with that of a fluid bous. The transit time for the apex of the bolus was shorter than for the tail. A more marked elevation of the pharynx and larynx was followed by a shorter transit time. The width of the pharyngo-esophageal segment was larger in the transverse than in the sagittal diameter during the passage of the bolus and larger on solid compared with fluid swallow. Our results reflect the ability of pharyngeal swallow to be executed with precision and with few alterations due to variable bolus consistency.

  17. Lingual Thyroid Carcinoma: A Case Report and Review of Surgical Approaches in the Literature.

    Science.gov (United States)

    Stokes, William; Interval, Eric; Patel, Rusha

    2018-07-01

    Lingual thyroid cancer is a rare entity with a paucity of literature guiding methods of surgical treatment. Its location presents anatomic challenges with access and excision. We present a case of T4aN1b classical variant papillary thyroid carcinoma of the lingual thyroid that was removed without pharyngeal entry. We also present a review of the literature of this rare entity and propose a treatment algorithm to provide safe and oncologic outcomes. Our review of the literature found 28 case reports of lingual thyroid carcinoma that met search criteria. The trans-cervical/trans-hyoid approach was the most frequently used and provides safe oncologic outcomes. This was followed by the transoral approach and then lateral pharyngotomy. Complications reported across the series include 1 case of pharyngocutaneous fistula associated with mandibulotomy and postoperative respiratory distress requiring reintubation or emergent tracheostomy in 2 patients. The location of lingual thyroid carcinoma can be variable, and surgical management requires knowledge of adjacent involved structures to decrease the risk of dysphagia and airway compromise. In particular, for cases where there is extensive loss to swallowing mechanisms, laryngeal suspension can allow the patient to resume a normal diet after treatment.

  18. Sensation of stasis is poorly correlated with impaired esophageal bolus transport

    NARCIS (Netherlands)

    Bogte, A.; Bredenoord, A. J.; Oors, J.; Siersema, P. D.; Smout, A. J. P. M.

    2014-01-01

    It is common belief that symptoms of patients with non-obstructive dysphagia are the result of impaired bolus clearance in the esophagus, usually caused by esophageal motility disorders. We therefore investigated the relationship between transit of swallowed boluses and the symptom dysphagia. Twenty

  19. Dental Hygiene and Orthodontics: Effect of Ultrasonic Instrumentation on Bonding Efficacy of Different Lingual Orthodontic Brackets.

    Science.gov (United States)

    Scribante, Andrea; Sfondrini, Maria Francesca; Collesano, Vittorio; Tovt, Gaia; Bernardinelli, Luisa; Gandini, Paola

    2017-01-01

    Dental hygienists are often faced with patients wearing lingual orthodontic therapy, as ultrasonic instrumentation (UI) is crucial for oral health. As the application of external forces can lead to premature bonding failure, the aim of this study was to evaluate the effect of UI on shear bond strength (SBS) and on adhesive remnant index (ARI) of different lingual orthodontic brackets. 200 bovine incisors were divided into 10 groups. Four different lingual (STB, Ormco; TTR, Rocky Mountain Orthodontics; Idea, Leone; 2D, Forestadent) and vestibular control (Victory, 3M) brackets were bonded. UI was performed in half of specimens, whereas the other half did not receive any treatment. All groups were tested with a universal testing machine. SBS and ARI values were recorded. Statistical analysis was performed (significance: P = 0.05). TTR, Idea, and 2D lingual brackets significantly lowered SBS after UI, whereas for other braces no effect was recorded. Appliances with lower mesh area significantly reduced their adhesion capacity after UI. Moreover groups subjected to UI showed higher ARI scores than controls. UI lowered SBS of lingual appliances of small dimensions so particular care should be posed avoiding prolonged instrumentation around bracket base during plaque removal. Moreover, UI influenced also ARI scores.

  20. Lingual thyroid - report of two cases

    International Nuclear Information System (INIS)

    Souza, Ricardo Pires de; Abicalaf, Ricardo Souza; Pimentel, Claudia Andreia Rabay; Santos, Leynalze Ramos; Soares, Aldemir Humberto; Gois Filho, Jose Francisco de; Carvalho, Marcos Brasilino de; Rapoport, Abrao

    1997-01-01

    The authors report two cases of lingual thyroid, an uncommon developmental anomaly of embryogenesis characterized by a failure of the normal migration of thyroid tissue to the neck, with presence of the thyroid gland in the mid-line of the tongue base between circumvallate papillae and the epiglottis. The lesions may appear at nay time from birth to old age and have a predilection for females. The embryology, incidence, signs and symptoms, diagnostic methods and management are discussed. (author)

  1. A Patient-Specific Polylactic Acid Bolus Made by a 3D Printer for Breast Cancer Radiation Therapy.

    Science.gov (United States)

    Park, So-Yeon; Choi, Chang Heon; Park, Jong Min; Chun, MinSoo; Han, Ji Hye; Kim, Jung-In

    2016-01-01

    The aim of this study was to assess the feasibility and advantages of a patient-specific breast bolus made using a 3D printer technique. We used the anthropomorphic female phantom with breast attachments, which volumes are 200, 300, 400, 500 and 650 cc. We simulated the treatment for a right breast patient using parallel opposed tangential fields. Treatment plans were used to investigate the effect of unwanted air gaps under bolus on the dose distribution of the whole breast. The commercial Super-Flex bolus and 3D-printed polylactic acid (PLA) bolus were applied to investigate the skin dose of the breast with the MOSFET measurement. Two boluses of 3 and 5 mm thicknesses were selected. There was a good agreement between the dose distribution for a virtual bolus generated by the TPS and PLA bolus. The difference in dose distribution between the virtual bolus and Super-Flex bolus was significant within the bolus and breast due to unwanted air gaps. The average differences between calculated and measured doses in a 200 and 300 cc with PLA bolus were not significant, which were -0.7% and -0.6% for 3mm, and -1.1% and -1.1% for 5 mm, respectively. With the Super-Flex bolus, however, significant dose differences were observed (-5.1% and -3.2% for 3mm, and -6.3% and -4.2% for 5 mm). The 3D-printed solid bolus can reduce the uncertainty of the daily setup and help to overcome the dose discrepancy by unwanted air gaps in the breast cancer radiation therapy.

  2. Commentary on "Performance of a glucose meter with a built-in automated bolus calculator versus manual bolus calculation in insulin-using subjects".

    Science.gov (United States)

    Rossetti, Paolo; Vehí, Josep; Revert, Ana; Calm, Remei; Bondia, Jorge

    2012-03-01

    Since the early 2000s, there has been an exponentially increasing development of new diabetes-applied technology, such as continuous glucose monitoring, bolus calculators, and "smart" pumps, with the expectation of partially overcoming clinical inertia and low patient compliance. However, its long-term efficacy in glucose control has not been unequivocally proven. In this issue of Journal of Diabetes Science and Technology, Sussman and colleagues evaluated a tool for the calculation of the prandial insulin dose. A total of 205 insulin-treated patients were asked to compute a bolus dose in two simulated conditions either manually or with the bolus calculator built into the FreeStyle InsuLinx meter, revealing the high frequency of wrong calculations when performed manually. Although the clinical impact of this study is limited, it highlights the potential implications of low diabetesrelated numeracy in poor glycemic control. Educational programs aiming to increase patients' empowerment and caregivers' knowledge are needed in order to get full benefit of the technology. © 2012 Diabetes Technology Society.

  3. Cross-lingual tagger evaluation without test data

    DEFF Research Database (Denmark)

    Agic, Zeljko; Plank, Barbara; Søgaard, Anders

    2017-01-01

    We address the challenge of cross-lingual POS tagger evaluation in absence of manually annotated test data. We put forth and evaluate two dictionary-based metrics. On the tasks of accuracy prediction and system ranking, we reveal that these metrics are reliable enough to approximate test set-base......-based evaluation, and at the same time lean enough to support assessment for truly low-resource languages....

  4. The usefulness of esophagogram with marchmallow bolus in patients with esophageal related symptoms

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Sang Wook; Kim, Ki Whang; Park, Hyo Jin; Kim, Eun Kyung; Yu, Jeong Sik; Seo, Jung Kun; Kwon, Ryang; Shin, Hyung Cheol [Yonsei Univ. College of Medicine, Seoul (Korea, Republic of)

    1996-03-01

    To evaluate the usefulness of the esophagogram using marshmallow bolus in the evaluation of the causes of variable esophageal-related symptoms. Esophagograms using marshmallow bolus were performed on 44 patients with esophageal-related symptoms and on ten normal volunteers. Videofluoroscopic studies were also made. Patients were classified into three groups according to their esophageal-related symptoms ; those with dysphagia, those with globus symptom, and those with chest pain. Abnormal findings on an esophagogram with marshmallow were graded in to three categories ; mild, moderate, and severe. Provocation of the same symptom was also evaluated. Esophageal monometric studies were performed on 16 patients and those results were compared with the results obtained from the esophagogram using marshmallow bolus. The provocation rate of the some symptom was 33% in the first group, 47% in the second, and 24% in the third. The provocation rate was highest in the second group. The provocation rate was also higher in patients with a severe degree of abnormality on an esophagogram using marshmallow bolus. Where there were abnormal findings, an esophagogram using marshmallow bolus showed a higher abnormality rate than did a conventional esophagogram. In cases showing abnormal finding son the esophageal monometric study, an esophagogram using marshmallow bolus showed a higher provocation rate and more severe abnormality than in cases showing normal findings on manometric study. An esophagogram using marshmallow bolus will a useful radiologic screening modality for the evaluation of patients with esophageal-related symptoms.

  5. The usefulness of esophagogram with marchmallow bolus in patients with esophageal related symptoms

    International Nuclear Information System (INIS)

    Yoon, Sang Wook; Kim, Ki Whang; Park, Hyo Jin; Kim, Eun Kyung; Yu, Jeong Sik; Seo, Jung Kun; Kwon, Ryang; Shin, Hyung Cheol

    1996-01-01

    To evaluate the usefulness of the esophagogram using marshmallow bolus in the evaluation of the causes of variable esophageal-related symptoms. Esophagograms using marshmallow bolus were performed on 44 patients with esophageal-related symptoms and on ten normal volunteers. Videofluoroscopic studies were also made. Patients were classified into three groups according to their esophageal-related symptoms ; those with dysphagia, those with globus symptom, and those with chest pain. Abnormal findings on an esophagogram with marshmallow were graded in to three categories ; mild, moderate, and severe. Provocation of the same symptom was also evaluated. Esophageal monometric studies were performed on 16 patients and those results were compared with the results obtained from the esophagogram using marshmallow bolus. The provocation rate of the some symptom was 33% in the first group, 47% in the second, and 24% in the third. The provocation rate was highest in the second group. The provocation rate was also higher in patients with a severe degree of abnormality on an esophagogram using marshmallow bolus. Where there were abnormal findings, an esophagogram using marshmallow bolus showed a higher abnormality rate than did a conventional esophagogram. In cases showing abnormal finding son the esophageal monometric study, an esophagogram using marshmallow bolus showed a higher provocation rate and more severe abnormality than in cases showing normal findings on manometric study. An esophagogram using marshmallow bolus will a useful radiologic screening modality for the evaluation of patients with esophageal-related symptoms

  6. Torque Control During Intrusion on Upper Central Incisor in Labial and Lingual bracket System - A 3D Finite Element Study.

    Science.gov (United States)

    Pol, Tejas R; Vandekar, Meghna; Patil, Anuradha; Desai, Sanjana; Shetty, Vikram; Hazarika, Saptarshi

    2018-01-01

    The aim of present study was to investigate the difference of torque control during intrusive force on upper central incisors with normal, under and high torque in lingual and labial orthodontic systems through 3D finite element analysis. Six 3D models of an upper right central incisor with different torque were designed in Solid Works 2006. Software ANSYS Version 16.0 was used to evaluate intrusive force on upper central incisor model . An intrusive force of 0.15 N was applied to the bracket slot in different torque models and the displacements along a path of nodes in the upper central incisor was assessed. On application of Intrusive force on under torqued upper central incisor in Labial system produce labial crown movement but in Lingual system caused lingual movement in the apical and incisal parts. The same intrusive force in normal-torqued central incisor led to a palatal movement in apical and labial displacement of incisal edge in Lingual system and a palatal displacement in apical area and a labial movement in the incisal edge in Labial systemin. In overtorqued upper central incisor, the labial crown displacement in Labial system is more than Lingual system. In labial and lingual system on application of the same forces in upper central incisor with different inclinations showed different responses. The magnitudes of torque Loss during intrusive loads in incisors with normal, under and over-torque were higher in Labial system than Lingual orthodontic appliances. Key words: FEM, lingual orthodontics, intrusion, torque control, labial bracket systems.

  7. Assessment of injection bolus in first-pass radionuclide angiography. Evaluation of injection site and needle size

    International Nuclear Information System (INIS)

    Tonami, Syuichi; Inagaki, Syoichi; Yasui, Masakazu; Sugishita, Kouki; Yoshita, Hisashi; Nakamura, Mamoru; Kuranishi, Makoto

    1996-01-01

    First-pass radionuclide angiography (FPRNA) using a multi-crystal gamma camera can correctly provide many quantitative and qualitative indices of left ventricular function as well as anatomic information. A compact injection bolus of radiotracer is, however, essential to the first-pass study since the temporal separation of cardiac chambers is required for the first-pass acquisition. To examine which factors affect the quality of an injection bolus, 327 patients who had FPRNA in the anterior projection were randomized for injection site of radiotracer (right or left external jugular veins, and right antecubital vein) and needle size (19- or 21-gauge). The injected bolus was assessed from the full width at half maximum (FWHM) of the bolus time-activity curve in the superior vena cava. As to injection site using a 19-gauge needle, an attemption through right external jugular vein (EJV) revealed the shortest FWHM of an injection bolus, followed by left EJV and right antecubital vein (AV). In right EJV 91% of injected bolus FWHM was less than 1.5 sec, which was significantly higher (p<0.001) than those of the other sites (left EJV: 70%. right AV: 65%). Approximately 7% of injection from left EJV and right AV, showed a split bolus of radiotracer. However, no split bolus was observed from right EJV. There was no significant difference in FWHM of an injection bolus between 19- and 21-gauge needle from EJV. Our present study demonstrated that the quality of an injection bolus from left EJV and AV was affected by RVEF in a case of low right ventricular function. In conclusion, right EJV is the first choice of injection site to obtain a compact bolus of radiotracer for the first-pass cardiac study. A 21-gauge needle can also be inserted from the external jugular vein to perform a good bolus injection. (author)

  8. Assessment of injection bolus in first-pass radionuclide angiography. Evaluation of injection site and needle size

    Energy Technology Data Exchange (ETDEWEB)

    Tonami, Syuichi; Inagaki, Syoichi; Yasui, Masakazu; Sugishita, Kouki; Yoshita, Hisashi; Nakamura, Mamoru; Kuranishi, Makoto [Toyama Medical and Pharmaceutical Univ. (Japan). Hospital

    1996-09-01

    First-pass radionuclide angiography (FPRNA) using a multi-crystal gamma camera can correctly provide many quantitative and qualitative indices of left ventricular function as well as anatomic information. A compact injection bolus of radiotracer is, however, essential to the first-pass study since the temporal separation of cardiac chambers is required for the first-pass acquisition. To examine which factors affect the quality of an injection bolus, 327 patients who had FPRNA in the anterior projection were randomized for injection site of radiotracer (right or left external jugular veins, and right antecubital vein) and needle size (19- or 21-gauge). The injected bolus was assessed from the full width at half maximum (FWHM) of the bolus time-activity curve in the superior vena cava. As to injection site using a 19-gauge needle, an attemption through right external jugular vein (EJV) revealed the shortest FWHM of an injection bolus, followed by left EJV and right antecubital vein (AV). In right EJV 91% of injected bolus FWHM was less than 1.5 sec, which was significantly higher (p<0.001) than those of the other sites (left EJV: 70%. right AV: 65%). Approximately 7% of injection from left EJV and right AV, showed a split bolus of radiotracer. However, no split bolus was observed from right EJV. There was no significant difference in FWHM of an injection bolus between 19- and 21-gauge needle from EJV. Our present study demonstrated that the quality of an injection bolus from left EJV and AV was affected by RVEF in a case of low right ventricular function. In conclusion, right EJV is the first choice of injection site to obtain a compact bolus of radiotracer for the first-pass cardiac study. A 21-gauge needle can also be inserted from the external jugular vein to perform a good bolus injection. (author)

  9. The use of Coca-Cola in the management of bolus obstruction in benign oesophageal stricture.

    Science.gov (United States)

    Karanjia, N. D.; Rees, M.

    1993-01-01

    Oesophageal stricture is a complication of oesophageal reflux and may itself be complicated by bolus obstruction. We reviewed the records of patients presenting with dysphagia and who were found to have benign oesophageal strictures. We studied the outcome of bolus obstruction in 13 episodes affecting eight patients. In six episodes Coca-Cola was administered on the day before endoscopy, and in all these patients the bolus had cleared. In seven episodes nothing was administered before endoscopy, and in all seven a bolus was evident at endoscopy. In five of these seven the bolus was removed piecemeal and in each of these instances the endoscope had to be passed between two and five times. In the remaining two instances the procedure was abandoned and the patients returned to the ward for the administration of Coca-Cola. At subsequent endoscopy these patients were found to be clear of any bolus. These results suggest that the administration of Coca-Cola (or other aerated drinks) may clear a bolus in the acutely obstructed oesophagus. PMID:8476194

  10. Oral declines and mastication deficiencies cause alteration of food bolus properties.

    Science.gov (United States)

    Peyron, M-A; Santé-Lhoutellier, V; François, O; Hennequin, M

    2018-02-21

    In the elderly, masticatory function often presents failure in certain oral tasks due to impairment such as decline in muscular force, jaw or tongue motility, neuro-muscular coordination, tooth damage, malocclusion and saliva production. Great disparity is observed in the various and potentially cumulative oral declines that occur with ageing. Such difficulties may have an impact on food consumption and nutritional status. To obtain better understanding of the consequences of several oral deficiencies, a series of swallowable boluses were prepared in vitro with the AM 2 masticator apparatus with normal and deficient programming. Physiological normal mastication (NM) was simulated using in vivo data from healthy subjects. Chewing deficiencies were reproduced by alteration of NM programming to perform different levels and combinations of force loss, lack of saliva and decrease in the motility of oral elements. Poultry meatballs were used as test-food. Particle size distribution in the food bolus was measured by sieving and rheological features (hardness, cohesiveness and elasticity) were assessed with a TPA test. Compared to the NM outcome, significant and gradual deterioration of the food bolus was observed and associated with alteration in force, saliva and motility. Combinations of several failures led to greater or cumulative deficiencies in swallowable bolus properties. For the elderly presenting a high prevalence of various oral injuries, tailoring textured food cannot be ignored as a solution for remedying deficiencies and favoring the formation of a safe-swallowable bolus, which is an essential vector of nutrients. Knowing the impacts of oral injuries on the food bolus is obviously a requisite for developing diet strategies, including nutritional items for specific populations.

  11. Comparison of the efficacy of tooth alignment among lingual and labial brackets: an in vitro study.

    Science.gov (United States)

    Alobeid, Ahmad; El-Bialy, Tarek; Reimann, Susanne; Keilig, Ludger; Cornelius, Dirk; Jäger, Andreas; Bourauel, Christoph

    2018-03-13

    The aim of this study was to evaluate the efficacy of tooth alignment with conventional and self-ligating labial and lingual orthodontic bracket systems. We tested labial brackets (0.022″ slot size) and lingual brackets (0.018″ slot size). The labial brackets were: (i) regular twin brackets (GAC-Twin [Dentsply]), (ii) passive self-ligating brackets including (Damon-Q® [ORMCO]; Ortho classic H4™ [Orthoclassic]; FLI®SL [RMO]), and (iii) active self-ligating brackets (GAC In-Ovation®C [DENTSPLY] and SPEED™[Strite]). The lingual brackets included (i) twin bracket systems (Incognito [3M] and Joy™ [Adenta]), (ii) passive self-ligating bracket system (GAC In-Ovation®LM™ [Dentsply]), and (iii) active self-ligating bracket system (Evolution SLT [Adenta]). The tested wires were Thermalloy-NiTi 0.013″ and 0.014″ (RMO). The archwires were tied to the regular twin brackets with stainless steel ligatures 0.010″ (RMO). The malocclusion simulated a displaced maxillary central incisor in the x-axis (2 mm gingivally) and in the z-axis (2 mm labially). The results showed that lingual brackets are less efficient in aligning teeth when compared with labial brackets in general. The vertical correction achieved by labial bracket systems ranged from 72 to 95 per cent with 13″ Thermalloy wires and from 70 to 87 per cent with 14″ Thermalloy wires. In contrast, the achieved corrections by lingual brackets with 13″ Thermalloy wires ranged between 25-44 per cent and 29-52 per cent for the 14" Thermalloy wires. The anteroposterior correction achieved by labial brackets ranged between 83 and 138 per cent for the 13″ Thermalloy and between 82 and 129 per cent for the 14″ Thermalloy wires. On the other hand, lingual brackets corrections ranged between 12 and 40 per cent for the 13″ Thermalloy wires and between 30 and 45 per cent for the 14″ Thermalloy wires. This is a lab-based study with different labial and lingual bracket slot sizes (however they are the

  12. A Patient-Specific Polylactic Acid Bolus Made by a 3D Printer for Breast Cancer Radiation Therapy.

    Directory of Open Access Journals (Sweden)

    So-Yeon Park

    Full Text Available The aim of this study was to assess the feasibility and advantages of a patient-specific breast bolus made using a 3D printer technique.We used the anthropomorphic female phantom with breast attachments, which volumes are 200, 300, 400, 500 and 650 cc. We simulated the treatment for a right breast patient using parallel opposed tangential fields. Treatment plans were used to investigate the effect of unwanted air gaps under bolus on the dose distribution of the whole breast. The commercial Super-Flex bolus and 3D-printed polylactic acid (PLA bolus were applied to investigate the skin dose of the breast with the MOSFET measurement. Two boluses of 3 and 5 mm thicknesses were selected.There was a good agreement between the dose distribution for a virtual bolus generated by the TPS and PLA bolus. The difference in dose distribution between the virtual bolus and Super-Flex bolus was significant within the bolus and breast due to unwanted air gaps. The average differences between calculated and measured doses in a 200 and 300 cc with PLA bolus were not significant, which were -0.7% and -0.6% for 3mm, and -1.1% and -1.1% for 5 mm, respectively. With the Super-Flex bolus, however, significant dose differences were observed (-5.1% and -3.2% for 3mm, and -6.3% and -4.2% for 5 mm.The 3D-printed solid bolus can reduce the uncertainty of the daily setup and help to overcome the dose discrepancy by unwanted air gaps in the breast cancer radiation therapy.

  13. A new approach to incisor retention--the lingual spur retainer.

    LENUS (Irish Health Repository)

    McNamara, T G

    1996-08-01

    Late lower incisor crowding and incisor rotations remain a problem in orthodontics. We describe a new fixed retainer which is simple to use, allows physiological tooth movement, but prevents rotational and labio-lingual relapse.

  14. Four cases of MALT lymphoma arising in the lingual tonsil

    International Nuclear Information System (INIS)

    Ogihara, Hitomi; Yuta, Atsushi; Yamaguchi, Motoko; Miyamoto, Yukiko; Hattori, Reiko; Imai, Hiroshi; Majima, Yuichi; Tanaka, Chikako

    2007-01-01

    We report four cases of lingual tonsillar MALT (mucosal associated lymphoid tissue) lymphoma. The cases consisted of a 68-year-old woman, a 60-year-old woman, a 55-year-old woman, and a 75-year-old man. The clinical stages of these cases were IIA, IA, IV (invasion to bone marrow) and IA, respectively. As some types of lingual tonsillar MALT lymphomas show hypertrophy of the lymphoid tissue but not a mass, it is not easy to make a diagnosis of MALT lymphoma only by fiberscopic findings. Furthermore, the small size of biopsy specimens or tissue damaged by forceps can show a false negative consult. Repeat biopsies are sometimes required for a definitive diagnosis. It is important to take large biopsy specimens with little damage, and to discuss well with pathologists. (author)

  15. Endoleak detection using single-acquisition split-bolus dual-energy computer tomography (DECT)

    Energy Technology Data Exchange (ETDEWEB)

    Javor, D.; Wressnegger, A.; Unterhumer, S.; Kollndorfer, K.; Nolz, R.; Beitzke, D.; Loewe, C. [Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria)

    2017-04-15

    To assess a single-phase, dual-energy computed tomography (DECT) with a split-bolus technique and reconstruction of virtual non-enhanced images for the detection of endoleaks after endovascular aneurysm repair (EVAR). Fifty patients referred for routine follow-up post-EVAR CT and a history of at least one post-EVAR follow-up CT examination using our standard biphasic (arterial and venous phase) routine protocol (which was used as the reference standard) were included in this prospective trial. An in-patient comparison and an analysis of the split-bolus protocol and the previously used double-phase protocol were performed with regard to differences in diagnostic accuracy, radiation dose, and image quality. The analysis showed a significant reduction of radiation dose of up to 42 %, using the single-acquisition split-bolus protocol, while maintaining a comparable diagnostic accuracy (primary endoleak detection rate of 96 %). Image quality between the two protocols was comparable and only slightly inferior for the split-bolus scan (2.5 vs. 2.4). Using the single-acquisition, split-bolus approach allows for a significant dose reduction while maintaining high image quality, resulting in effective endoleak identification. (orig.)

  16. Mini-screws, a viable adjunct along with Incognito lingual appliance: A case series

    Directory of Open Access Journals (Sweden)

    Wei Lin

    2015-01-01

    Full Text Available Invisible orthodontics have been around for too long, and with the advent of computer-aided design/computer-aided manufacturing technology appliances such as Incognito TM has made the whole treatment experience more pleasant and aesthetic. However, even in lingual orthodontics, biomechanics play the most important role, and the use of temporary anchorage devices (TADs has made the whole treatment more effective and efficient. This article focuses on cases where TADs in lingual appliances play a critical role in the treatment of various malocclusions.

  17. Rapid contrast infusion of bolus injection for i.v. urography

    International Nuclear Information System (INIS)

    Kaltenborn, H.; Klose, P.; Klose, K.; Schmiedel, E.

    1993-01-01

    The rate of contrast injection during i.v. urography may vary considerably (bolus injection or drip infusion). The effect of 5 rates of injection (6, 12, 18, 36 and 72 ml/min) on the contrast density in the renal collecting system was examined over a period of 30 minutes. Measurements showed an inter-individual difference of more than 200% in each group. The intra-individual variations for different rates of injection were very slight; individual concentration in the kidney for a given dose depends only slightly on the rate of injection. There is no statistically significant improvement in contrast values as a result of a bolus injection. The reduced incidence of side effects justifies the use of bolus injections but pressure injections are unnecessary from a diagnostic point view. (orig.) [de

  18. Neurotrophins and their receptors in human lingual tonsil: an immunohistochemical analysis.

    Science.gov (United States)

    Artico, Marco; Bronzetti, Elena; Felici, Laura M; Alicino, Valentina; Ionta, Brunella; Bronzetti, Benedetto; Magliulo, Giuseppe; Grande, Claudia; Zamai, Loris; Pasquantonio, Guido; De Vincentiis, Marco

    2008-11-01

    Lymphoid organs are supplied by many nerve endings associated with different kinds of cells and macrophages. The role of this innervation on the release of locally active molecules is still unclear. Lingual tonsils belong to Waldeyer's Ring, in close association with palatine tonsils and nasopharyngeal (adenoids) tonsils, thus constituting part of NALT (nasal-associated lymphoid tissue) together with the tubal tonsils and lateral pharyngeal bands. In this study, we focused our attention on the expression of some neurotrophins (NTs) and their high- and low-affinity receptors in human lingual tonsils. Light immunohistochemistry showed that human tonsillar samples were generally positive for all the NTs investigated (NGF, BDNF, NT-3, NT-4) and their receptors (TrKA, TrKB, TrKC and p75) with some different expression levels. NGF and TrKC were strongly expressed in macrophages, but weakly in lymphocytes. However, BDNF and TrKB was highly expressed in lymphocytes and weaker in macrophages. The low-affinity receptor for NGF, p75, was mainly moderately expressed in the analysed samples. These results suggest the presence of a pattern of neurotrophin innervation in the human lingual tonsil which may play a role in sustaining inflammatory conditions and in modulating a close interaction between the nervous system and the different immune cellular subtypes.

  19. A Bolus Calculator Based on Continuous-Discrete Unscented Kalman Filtering for Type 1 Diabetics

    DEFF Research Database (Denmark)

    Boiroux, Dimitri; Aradóttir, Tinna Björk; Hagdrup, Morten

    2015-01-01

    both reduces the risk of hypoglycemia in case of an overestimated meal and the time spent in hyperglycemia if the meal size is underestimated. Faster insulin and the use of glucagon will have the potential to encourage postprandial meal bolus administration and hence will not require to accurately......In patients with type 1 diabetes, the effects of meals intake on blood glucose level are usually mitigated by administering a large amount of insulin (bolus) at mealtime or even slightly before. This strategy assumes, among other things, a prior knowledge of the meal size and the postprandial...... glucose dynamics. On the other hand, administering the meal bolus during or after mealtime could benefit from the information provided by the postprandial meal dynamics at the expense of a delayed meal bolus. The present paper investigates different bolus administration strategies (at mealtime, 15 minutes...

  20. Lingual Kinematics during Rapid Syllable Repetition in Parkinson's Disease

    Science.gov (United States)

    Wong, Min Ney; Murdoch, Bruce E.; Whelan, Brooke-Mai

    2012-01-01

    Background: Rapid syllable repetition tasks are commonly used in the assessment of motor speech disorders. However, little is known about the articulatory kinematics during rapid syllable repetition in individuals with Parkinson's disease (PD). Aims: To investigate and compare lingual kinematics during rapid syllable repetition in dysarthric…

  1. 21 CFR 520.1242b - Levamisole hydrochloride tablet or oblet (bolus).

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Levamisole hydrochloride tablet or oblet (bolus... § 520.1242b Levamisole hydrochloride tablet or oblet (bolus). (a) Chemical name. (-)-2,3,5,6-Tetrahydro... using in severely debilitated animals. (2) It is used in a tablet for sheep as follows: (i) Amount. 0...

  2. Are there more adverse effects with lingual orthodontics?

    Science.gov (United States)

    Madurantakam, Parthasarathy; Kumar, Satish

    2017-12-22

    Data sourcesPubMed, Embase, Cochrane Library and LILACS database, review of references cited in included articles and a manual search of leading orthodontic journals. No language restrictions were imposed in the search. Study authors were contacted when necessary.Study selectionRandomised controlled trials (RCTs) and controlled clinical trials (CCTs) in healthy patients that directly compared the adverse effects following treatment using buccal and lingual appliances. Studies involving single arch or dual arch appliances were considered. Studies on patients with systemic diseases, animal studies and in vitro studies were excluded. The primary outcomes of interest to the authors were a list of adverse effects: pain, caries, eating and speech difficulties and oral hygiene.Data extraction and synthesisTwo authors reviewed the titles and abstracts of all studies identified through the search without blinding to names of authors or publication dates. Selected articles from searches were evaluated independently by two authors against established inclusion criteria, disagreements were resolved by consensus or by consulting a third author. Two authors independently assessed the risk of bias using the Cochrane Collaboration's tool (randomised trials) and the Newcastle-Ottawa Scale for non-randomised studies. The level of agreement between the authors was assessed using the Cohen kappa statistic. A meta-analysis was performed to provide pooled effect estimate (expressed as odds ratio) as well as 95% confidence interval. The outcomes of interest were pain, caries, eating difficulties, speech difficulties and deficient oral hygiene. Heterogeneity was quantified using I2 statistic and potential causes explored. Publication bias was assessed using a funnel plot.ResultsEight articles were included; three RCTs and five CCTs. One RCT was considered to be at high risk of bias, one moderate risk and one low risk. Of the non-randomised studies, four were low risk and one was high risk

  3. Mental foramen and lingual vascular canals of mandible on MDCT images: anatomical study and review of the literature.

    Science.gov (United States)

    Direk, Filiz; Uysal, Ismihan Ilknur; Kivrak, Ali Sami; Fazliogullari, Zeliha; Unver Dogan, Nadire; Karabulut, Ahmet Kagan

    2018-03-01

    The mental foramen and lingual vascular canals are related to vessels and nerves in the mandibular body. The aim of the present study was to determine the number and location of these structures and to make measurements of them. The archived Multidetector Computed Tomography images of 100 adult (15- to 70-year-old) patients were evaluated retrospectively. The diameters of the mental foramens and their distances from the front, back, upper and lower reference points were measured. The distribution of mental foramens with respect to the teeth was also researched. The presence of lingual vascular canals, and the number of median and lateral canals was determined, and the length of the median lingual vascular canals measured. All measurement parameters were analyzed by gender, side and age group. Eleven patients demonstrated a total of 15 accessory mental foramen. Median lingual vascular canals were observed in 100% of cases, with lateral lingual vascular canals determined in 32%. Significant differences were observed in the results of different gender groups (P mental foramen was determined mostly in males, and unilaterally on the right side; also, the distances of mental foramen, except the distance from the back border of the mandible (P mental foramen, as well as the presence, position and size of lingual vascular canals can be clearly investigated by multidetector computed tomography. A preoperative knowledge of the positions of neurovascular and bone structures is very important for preventing complications that may occur during or after operations.

  4. Evaluation of a Water-based Bolus Device for Radiotherapy to the Extremities in Kaposi's Sarcoma Patients

    International Nuclear Information System (INIS)

    Ahn, Seung Kwon; Kim, Yong Bae; Lee, Ik Jae

    2008-01-01

    We designed a water-based bolus device for radiation therapy in Kaposi's sarcoma. This study evaluated the usefulness of this new device and compared it with the currently used rice-based bolus. Materials and Methods: We fashioned a polystyrene box and cut a hole in order to insert patient's extremities while the patient was in the supine position. We used a vacuum-vinyl based polymer to reduce water leakage. Next, we eliminated air using a vacuum pump and a vacuum valve to reduce the air gap between the water and extremities in the vacuum-vinyl box. We performed CT scans to evaluate the density difference of the fabricated water-based bolus device when the device in which the rice-based bolus was placed directly, the rice-based bolus with polymer-vinyl packed rice, and the water were all put in. We analyzed the density change with the air gap volume using a planning system. In addition, we measured the homogeneity and dose in the low-extremities phantom, attached to six TLD, and wrapped film exposed in parallel-opposite fields with the LINAC under the same conditions as the set-up of the CT-simulator. Results: The density value of the rice-based bolus with the rice put in directly was 14% lower than that of the water-based bolus. Moreover, the value of the other experiments in the rice-based bolus with the polymer-vinyl packed rice showed an 18% reduction in density. The analysis of the EDR2 film revealed that the water-based bolus shows a more homogeneous dose plan, which was superior by 4.0-4.4% to the rice-base bolus. The mean TLD readings of the rice-based bolus, with the rice put directly into the polystyrene box had a 3.4% higher density value. Moreover, the density value in the case of the rice-based bolus with polymer-vinyl packed rice had a 4.3% higher reading compared to the water-based bolus. Conclusion: Our custom-made water-based bolus device increases the accuracy of the set-up by confirming the treatment field. It also improves the accuracy of the

  5. Fast-flow lingual vascular anomalies in the young patient: is imaging diagnostic?

    International Nuclear Information System (INIS)

    Khong, Pek-Lan; Burrows, Patricia E.; Kozakewich, Harry P.; Mulliken, John B.

    2003-01-01

    To describe the imaging findings (MR imaging and angiography) of high-flow vascular anomalies of the tongue, hemangiomas and arteriovenous malformations (AVMs), with emphasis on the discrepant imaging findings in lingual AVMs. Retrospective review of clinical records, histologic reports and imaging studies of five consecutive patients with high-flow lingual vascular anomalies. One patient had hemangioma (aged 1 month) and four patients had AVMs (aged 15 months, 6, 24, and 33 years). Diagnosis was made on the basis of histology in four lesions and was based on typical clinical history in one lesion. MR imaging and angiographic findings of the hemangioma were typical, but similar findings of focal hyperintense mass on T2-weighted images and angiographic stain were seen in three AVMs (patients aged 15 months, 6 and 33 years). On angiography, there was no nidus or direct arteriovenous (AV) shunting in one AVM (patient aged 15 months). The fourth AVM had typical MR imaging and angiographic findings. The imaging findings in lingual AVMs can be atypical or inconclusive and can mimic hemangiomas, especially in the young patient. Since treatment depends on accurate diagnosis, biopsy may be necessary for lesions with inconclusive imaging findings. (orig.)

  6. Lingual mucosal graft two-stage Bracka technique for redo hypospadias repair

    Directory of Open Access Journals (Sweden)

    Ahmed Sakr

    2017-09-01

    Conclusion: Lingual mucosa is a reliable and versatile graft material in the armamentarium of two-stage Bracka hypospadias repair with the merits of easy harvesting and minor donor-site complications.

  7. Analyses of anatomical relationship between mandibular third molar roots and variations in lingual undercut of mandible using cone-beam computed tomography

    Directory of Open Access Journals (Sweden)

    Sertac Aktop

    2017-09-01

    Conclusion: The narrow angulation of the lingual balcony region and the relationship between roots and lingual soft tissues should be noted to avoid undesirable complication of displacement of a tooth or fragment into sublingual, submandibular, and pterygomandibular spaces. There was no relation in the floor of the mouth between the position of the impacted third molar roots and different lingual undercut angulation variations.

  8. The study of comminution behavior of food on buccal and lingual side during mastication.

    Science.gov (United States)

    Kawashima, Kumiko; Miura, Hiroyuki; Kato, Hitoshi; Yoshida, Keiichi; Tanaka, Yoshihiro

    2009-12-01

    In this study, we observed comminution behavior of food on buccal and lingual side by sieve method. Six dentate subjects participated in this study. Peanuts were used as the test food and chewed for 1-8, 10, 12, 14, 16, 18, 20, 22 and 24 strokes on their preferred chewing side. Peanuts were gathered separately from buccal and lingual sides after varying number of chewing strokes. The crushed peanuts were sieved through a stack of eight level sieves (0.85 to 5.6mm). The comminution of coarse particles above 4.75 mm was almost finished within 10 strokes. The dynamic change in the median particle size also disappeared about 10 strokes. This suggested that we should pay attention to the initial phase of the chewing when we observed about mastication. As a result, comminution behavior of lingual coarse particles better conformed to fluctuation of median particle sizes of whole mouth, expressing masticatory performance precisely, than that of buccal coarse particles.

  9. Lingual and fusiform gyri in visual processing: a clinico-pathologic study of superior altitudinal hemianopia.

    OpenAIRE

    Bogousslavsky, J; Miklossy, J; Deruaz, J P; Assal, G; Regli, F

    1987-01-01

    A macular-sparing superior altitudinal hemianopia with no visuo-psychic disturbance, except impaired visual learning, was associated with bilateral ischaemic necrosis of the lingual gyrus and only partial involvement of the fusiform gyrus on the left side. It is suggested that bilateral destruction of the lingual gyrus alone is not sufficient to affect complex visual processing. The fusiform gyrus probably has a critical role in colour integration, visuo-spatial processing, facial recognition...

  10. Cell fate specification in the lingual epithelium is controlled by antagonistic activities of Sonic hedgehog and retinoic acid.

    Science.gov (United States)

    El Shahawy, Maha; Reibring, Claes-Göran; Neben, Cynthia L; Hallberg, Kristina; Marangoni, Pauline; Harfe, Brian D; Klein, Ophir D; Linde, Anders; Gritli-Linde, Amel

    2017-07-01

    The interaction between signaling pathways is a central question in the study of organogenesis. Using the developing murine tongue as a model, we uncovered unknown relationships between Sonic hedgehog (SHH) and retinoic acid (RA) signaling. Genetic loss of SHH signaling leads to enhanced RA activity subsequent to loss of SHH-dependent expression of Cyp26a1 and Cyp26c1. This causes a cell identity switch, prompting the epithelium of the tongue to form heterotopic minor salivary glands and to overproduce oversized taste buds. At developmental stages during which Wnt10b expression normally ceases and Shh becomes confined to taste bud cells, loss of SHH inputs causes the lingual epithelium to undergo an ectopic and anachronic expression of Shh and Wnt10b in the basal layer, specifying de novo taste placode induction. Surprisingly, in the absence of SHH signaling, lingual epithelial cells adopted a Merkel cell fate, but this was not caused by enhanced RA signaling. We show that RA promotes, whereas SHH, acting strictly within the lingual epithelium, inhibits taste placode and lingual gland formation by thwarting RA activity. These findings reveal key functions for SHH and RA in cell fate specification in the lingual epithelium and aid in deciphering the molecular mechanisms that assign cell identity.

  11. Cell fate specification in the lingual epithelium is controlled by antagonistic activities of Sonic hedgehog and retinoic acid.

    Directory of Open Access Journals (Sweden)

    Maha El Shahawy

    2017-07-01

    Full Text Available The interaction between signaling pathways is a central question in the study of organogenesis. Using the developing murine tongue as a model, we uncovered unknown relationships between Sonic hedgehog (SHH and retinoic acid (RA signaling. Genetic loss of SHH signaling leads to enhanced RA activity subsequent to loss of SHH-dependent expression of Cyp26a1 and Cyp26c1. This causes a cell identity switch, prompting the epithelium of the tongue to form heterotopic minor salivary glands and to overproduce oversized taste buds. At developmental stages during which Wnt10b expression normally ceases and Shh becomes confined to taste bud cells, loss of SHH inputs causes the lingual epithelium to undergo an ectopic and anachronic expression of Shh and Wnt10b in the basal layer, specifying de novo taste placode induction. Surprisingly, in the absence of SHH signaling, lingual epithelial cells adopted a Merkel cell fate, but this was not caused by enhanced RA signaling. We show that RA promotes, whereas SHH, acting strictly within the lingual epithelium, inhibits taste placode and lingual gland formation by thwarting RA activity. These findings reveal key functions for SHH and RA in cell fate specification in the lingual epithelium and aid in deciphering the molecular mechanisms that assign cell identity.

  12. Delivery confirmation of bolus electron conformal therapy combined with intensity modulated x-ray therapy

    International Nuclear Information System (INIS)

    Kavanaugh, James A.; Hogstrom, Kenneth R.; Fontenot, Jonas P.; Henkelmann, Gregory; Chu, Connel; Carver, Robert A.

    2013-01-01

    Purpose: The purpose of this study was to demonstrate that a bolus electron conformal therapy (ECT) dose plan and a mixed beam plan, composed of an intensity modulated x-ray therapy (IMXT) dose plan optimized on top of the bolus ECT plan, can be accurately delivered. Methods: Calculated dose distributions were compared with measured dose distributions for parotid and chest wall (CW) bolus ECT and mixed beam plans, each simulated in a cylindrical polystyrene phantom that allowed film dose measurements. Bolus ECT plans were created for both parotid and CW PTVs (planning target volumes) using 20 and 16 MeV beams, respectively, whose 90% dose surface conformed to the PTV. Mixed beam plans consisted of an IMXT dose plan optimized on top of the bolus ECT dose plan. The bolus ECT, IMXT, and mixed beam dose distributions were measured using radiographic films in five transverse and one sagittal planes for a total of 36 measurement conditions. Corrections for film dose response, effects of edge-on photon irradiation, and effects of irregular phantom optical properties on the Cerenkov component of the film signal resulted in high precision measurements. Data set consistency was verified by agreement of depth dose at the intersections of the sagittal plane with the five measured transverse planes. For these same depth doses, results for the mixed beam plan agreed with the sum of the individual depth doses for the bolus ECT and IMXT plans. The six mean measured planar dose distributions were compared with those calculated by the treatment planning system for all modalities. Dose agreement was assessed using the 4% dose difference and 0.2 cm distance to agreement. Results: For the combined high-dose region and low-dose region, pass rates for the parotid and CW plans were 98.7% and 96.2%, respectively, for the bolus ECT plans and 97.9% and 97.4%, respectively, for the mixed beam plans. For the high-dose gradient region, pass rates for the parotid and CW plans were 93.1% and 94

  13. Effect of chest wall radiotherapy in different manners using tissue equivalent bolus on skin and lung of cavia cobayas

    International Nuclear Information System (INIS)

    Huang Wei; Qu Yaqin; Song Xiangfu; Liu Shixin; Jia Xiaojing; Guo He; Yang Lei

    2009-01-01

    Objective: To probe the influence of electron beam radiotherapy in different manners using different tissue equivalent boluses on skin and lung. Methods: Adult female cavia cobayas were randomly divided into four groups as control group, half-time with bolus group, half-time with bolus group and without bolus group. Acute-irradiation animal models were established using electron beam in different manners with or without 0.5 cm tissue equivalent bolus. Pathological changes in lung, hair vesicle and fibroblast cell count were analyzed 40 clays after irradiation. Results: The radiation dermatitis in the group with bolus was slighter than that of the group without bolus, but the radiation pneumonia was reverse. With bolus, the radiation dermatitis of haft-time group was slighter than that of full-time group. The injury repair of half-time group was more active than full-time group. Conclusions: The treatment of haft-time bolus could protect lung without serious skin complications. (authors)

  14. Incidence and risk factors for postoperative lingual neuropraxia following airway instrumentation: A retrospective matched case-control study.

    Directory of Open Access Journals (Sweden)

    Yi-Kai Su

    Full Text Available Lingual nerve injury or neuropraxia is a rare but potentially serious perioperative complication following airway instrumentation during general anesthesia. This study explored the the incidence and perioperative risk factors for lingual nerve injury in patients receiving laryngeal mask (LMA or endotracheal (ETGA general anesthesia in a single center experience.All surgical patients in our hospital who received LMA or ETGA from 2009 to 2013 were included, and potential perioperative risk factors were compared. Matched controls were randomly selected (in 1:5 ratio from the same database in non-case patients. A total of 36 patients in the records had reported experiencing tongue numbness after anesthesia in this study. Compared with the non-case surgical population (n = 54314, patients with tongue numbness were significantly younger (52.2±19.5 vs 42.0±14.5; P = 0.002 and reported lower ASA physical statuses (2.3±0.7 vs 1.6±0.6; P<0.001. Patient gender, anesthesia technique used, and airway device type (LMA or ETGA did not differ significantly across the two groups. A significantly higher proportion of patients underwent operations of the head-and-neck region (38.9 vs 15.6%; P = 0.002 developed tongue numbness after anesthesia. Multivariate logistic regression analysis indicated that head-and-neck operations remained the most significant independent risk factor for postoperative lingual nerve injury (AOR 7.63; 95% CI 2.03-28.70.The overall incidence rate of postoperative lingual neuropraxy was 0.066% in patients receiving general anesthesia with airway device in place. Young and generally healthy patients receiving head-and-neck operation are at higher risk in developing postoperative lingual neuropraxy. Attention should be particularly exercised to reduce the pressure of endotracheal tube or laryngeal mask on the tongue during head-and-neck operation to avert the occurrence of postoperative lingual neuropraxy.

  15. Comparison of the initial orthodontic force systems produced by a new lingual bracket system and a straight-wire appliance.

    Science.gov (United States)

    Fuck, Lars-Michael; Wiechmann, Dirk; Drescher, Dieter

    2005-09-01

    Over the last few years, lingual appliances have become an established orthodontic treatment technique. Many studies have concentrated on various esthetic aspects, on laboratory and clinical procedures, and on patient comfort and compliance. The orthodontic force systems of these appliances, however, have not yet been investigated. The aim of this study was thus to determine the forces and moments produced by a new lingual bracket system during the leveling phase of orthodontic treatment and to compare those with the corresponding force system of a labial straight-wire appliance. The intra-oral situation of ten patients undergoing orthodontic treatment was replicated in measurement casts fitted with lingual and labial brackets. Special care was taken to precisely reproduce each patient's interbracket geometry. We measured each tooth's force systems as generated by a leveling arch inserted into the lingual and labial brackets. The resulting force systems of both appliances were found to be quite similar with regard to the magnitude of most force and moment components. Only the first molars were subjected to considerably greater single forces with the lingual appliance. Tipping moments were found to be significantly smaller with the lingual technique, whereas the rotational moments were significantly smaller with the labial appliance. All in all we noted significant differences between the two techniques only in certain areas which upon closer examination were distributed over only a few tooth types. The initial force systems produced by the new lingual bracket system proved to be comparable with those delivered by a conventional straight-wire appliance. The actual levels of forces and moments, however, were found in certain cases to be too heavy with both techniques. We therefore recommend the development of leveling wires producing considerably lighter forces and moments.

  16. Determining shapes and dimensions of dental arches for the use of straight-wire arches in lingual technique.

    Science.gov (United States)

    Kairalla, Silvana Allegrini; Scuzzo, Giuseppe; Triviño, Tarcila; Velasco, Leandro; Lombardo, Luca; Paranhos, Luiz Renato

    2014-01-01

    This study aims to determine the shape and dimension of dental arches from a lingual perspective, and determine shape and size of a straight archwire used for lingual Orthodontics. The study sample comprised 70 Caucasian Brazilian individuals with normal occlusion and at least four of Andrew's six keys. Maxillary and mandibular dental casts were digitized (3D) and the images were analyzed by Delcam Power SHAPET 2010 software. Landmarks on the lingual surface of teeth were selected and 14 measurements were calculated to determine the shape and size of dental arches. Shapiro-Wilk test determined small arch shape by means of 25th percentile (P25%)--an average percentile for the medium arch; and a large one determined by means of 75th percentile (P75%). T-test revealed differences between males and females in the size of 12 dental arches. The straight-wire arch shape used in the lingual straight wire technique is a parabolic-shaped arch, slightly flattened on its anterior portion. Due to similarity among dental arch sizes shown by males and females, a more simplified diagram chart was designed.

  17. The nance lingual arch: an auxiliary device in solving lower anterior crowding.

    Science.gov (United States)

    Almeida, Renato Rodrigues de; Oltramari-Navarro, Paula Vanessa Pedron; Almeida, Marcio Rodrigues de; Conti, Ana Cláudia de Castro Ferreira; Navarro, Ricardo de Lima; Pacenko, Murilo Rizental

    2011-01-01

    After exfoliation of the primary incisors and eruption of the permanent incisors, the dentist has the opportunity of observing closely the beginning of occlusal changes. In several cases, alterations, such as lower anterior crowding, can be prevented and treated with proper follow-up. In the mixed dentition, one of the mechanisms for maintaining space and favoring dental alignment is to preserve leeway space before permanent second molar irruption. Among the devices with this function, the Nance lingual arch helps maintaining the position of the permanent mandibular molars and incisors after a premature loss of the primary canines. This paper describes the applicability of Nance lingual arch for preserving leeway space, thus contributing for correction of lower anterior crowding.

  18. The Consideration of Bolus Effects of Games Attached on Lesion area

    International Nuclear Information System (INIS)

    Park, Ju Young; Ju, Sang Kyu; Park, Young Chul; Han, Young Yi; Shin, Eun Hyuk; Park, Yong Hwan

    2004-01-01

    The aim of this study is to evaluate the effect of skin dose and PDD by using wounds protecting gauzes or Vaselinespread gauzes. And it was studied that the possibility to substitute custom bolus into gauzes. 4 MV photon (CL600C, varian, US), Polystyrene Phantom (30(W) X 30(L) X 30(H)) with Markus chamber(PTW, US) were used for dose measurement. This study was distinguished natural gauzes and spread over Vaseline gauzes. We gave variety to the gauze thickness at 5, 10 and 15 sheets respectively. For comparison between using bolus and not that, we had used 1.0 cm thickness bolus so that analyzed surface dose and PDD at the same conditions above mentioned. When maximum point was defined as reference point, surface dose was measured as 35% in open beam. When the gauzes were attached to surface as 5, 10 and 15 sheets, surface dose were increased as 69, 80 and 91% respectively according to thickness of gauzes. When spread over Vaseline gauzes were attached to surface as 5, 10 and 15 sheets, surface dose were increased respectively as 98, 100 and 98% according to thickness of gauzes. Also when 0.5 cm bolus and 5 sheets gauzes were composed, surface dose was measured as 98%. The gauzes that were attached to skin surface in radiation therapy had been scattering material and contributed increasing surface dose without variation of percentage depth dose. However, if we want to delivery much dose to skin surface then we have to apply many sheets of gauzes to skin surface. Although we get easy that result by bolus or spread over Vaseline gauzes, we have to revise percentage depth dose at calculation. Therefore, if we find pertinent conditions based on measured data that are considered skin dose and patient setup efficiency, to replace custom bolus with gauzes will be helpful to efficient treatment.

  19. Scanning Electron Microscopic Structure of the Lingual Papillae of the Common Opossum (Didelphis marsupialis)

    Science.gov (United States)

    Okada, Shigenori; Schraufnagel, Dean E.

    2005-08-01

    The mammalian tongue has evolved for specialized functions in different species. The structure of its papillae tells about the animal's diet, habit, and taxonomy. The opossum has four kinds of lingual papillae (filiform, conical, fungiform, vallate). Scanning electron microscopy of the external features, connective tissue cores, and corrosion casts of the microvasculature show the filiform papillae have a spearhead-like main process and spiny accessory processes around the apical part of the main process. The shape and number of both processes depend on their position on the tongue. On the apex, the main processes have shovel-like capillary networks and the accessory processes have small conical networks. On the lingual radix, the processes have small capillary loops. In the patch region, conical papillae have capillaries arranged as a full sail curving posteriorly. The fungiform papillae are scattered among the filiform papillae and have capillary baskets beneath each taste bud. Giant fungiform papillae on the tongue tip are three to four times larger than the ones on the lingual body. Capillaries of giant papillae form a fan-shaped network. The opossum has three vallate papillae arranged in a triangle. Their tops have secondary capillary loops but not their lateral surfaces. Mucosal folds on the posterolateral border have irregular, fingerlike projections with cylindrical capillary networks. These findings and the structure of the rest of the masticatory apparatus suggest the lingual papillae of opossum have kept their ancestral carnivorous features but also developed the herbivore characteristics of other marsupials.

  20. SU-F-T-500: The Effectiveness of a Patient Specific Bolus Made by Using Three-Dimensional Printing Technique in Photon Radiotherapy

    International Nuclear Information System (INIS)

    Fujimoto, K; Yuasa, Y; Shiinoki, T; Hanazawa, H; Shibuya, K

    2016-01-01

    Purpose: A commercially available bolus (commercial-bolus) would not completely contact with the irregular shape of a patient’s skin. The purposes of this study were to customize a patient specific three-dimensional (3D) bolus using a 3D printer (3D-bolus) and to evaluate its clinical feasibility for photon radiotherapy. Methods: The 3D-bolus was designed using a treatment planning system (TPS) in DICOM-RT format. To print the 3D bolus, the file was converted into stereolithography format. To evaluate its physical characteristics, plans were created for water equivalent phantoms without the bolus, with the 3D-bolus printed in a flat form, and with the virtual bolus which supposed a commercial-bolus. These plans were compared with the percent depth dose (PDD) measured from the TPS. Furthermore, to evaluate its clinical feasibility, the treatment plans were created for RANDO phantoms without the bolus and with the 3D-bolus which was customized for contacting with the surface of the phantom. Both plans were compared with the dose volume histogram (DVH) of the target volume. Results: In the physical evaluation, dmax of the plan without the bolus, with the 3D-bolus, and with the virtual bolus were 2.2 cm, 1.6 cm, and 1.7 cm, respectively. In the evaluation of clinical feasibility, for the plan without the bolus, Dmax, Dmin, Dmean, D90%, and V90% of the target volume were 102.6 %, 1.6 %, 88.8 %, 57.2 %, and 69.3 %, respectively. By using the 3D-bolus, the prescription dose could be delivered to at least 90 % of the target volume, Dmax, Dmin, Dmean, D90%, and V90% of the target volume were 104.3 %, 91.6 %, 92.1 %, 91.7 %, and 98.0 %, respectively. The 3D-bolus has the potential to be useful for providing effective dose coverage in the buildup region. Conclusion: A 3D-bolus produced using 3D printing technique is comparable to a commercially available bolus.

  1. SU-F-T-500: The Effectiveness of a Patient Specific Bolus Made by Using Three-Dimensional Printing Technique in Photon Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Fujimoto, K; Yuasa, Y [Department of Radiological Technology, Yamaguchi University Hospital (Japan); Shiinoki, T; Hanazawa, H; Shibuya, K [Department of Radiation Oncology, Graduate school of Medicine, Yamaguchi University (Japan)

    2016-06-15

    Purpose: A commercially available bolus (commercial-bolus) would not completely contact with the irregular shape of a patient’s skin. The purposes of this study were to customize a patient specific three-dimensional (3D) bolus using a 3D printer (3D-bolus) and to evaluate its clinical feasibility for photon radiotherapy. Methods: The 3D-bolus was designed using a treatment planning system (TPS) in DICOM-RT format. To print the 3D bolus, the file was converted into stereolithography format. To evaluate its physical characteristics, plans were created for water equivalent phantoms without the bolus, with the 3D-bolus printed in a flat form, and with the virtual bolus which supposed a commercial-bolus. These plans were compared with the percent depth dose (PDD) measured from the TPS. Furthermore, to evaluate its clinical feasibility, the treatment plans were created for RANDO phantoms without the bolus and with the 3D-bolus which was customized for contacting with the surface of the phantom. Both plans were compared with the dose volume histogram (DVH) of the target volume. Results: In the physical evaluation, dmax of the plan without the bolus, with the 3D-bolus, and with the virtual bolus were 2.2 cm, 1.6 cm, and 1.7 cm, respectively. In the evaluation of clinical feasibility, for the plan without the bolus, Dmax, Dmin, Dmean, D90%, and V90% of the target volume were 102.6 %, 1.6 %, 88.8 %, 57.2 %, and 69.3 %, respectively. By using the 3D-bolus, the prescription dose could be delivered to at least 90 % of the target volume, Dmax, Dmin, Dmean, D90%, and V90% of the target volume were 104.3 %, 91.6 %, 92.1 %, 91.7 %, and 98.0 %, respectively. The 3D-bolus has the potential to be useful for providing effective dose coverage in the buildup region. Conclusion: A 3D-bolus produced using 3D printing technique is comparable to a commercially available bolus.

  2. Evaluation of 133Xe clearance curves in the study of lingual blood flow in dogs

    International Nuclear Information System (INIS)

    Fazekas, A.; Posch, E.; Harsing, L.

    1979-01-01

    Lingual blood flow was studied in dogs by the 133 Xe clearance technique under control conditions, during epinephrine infusion and in response to a combined treatment with regitin and epinephrine. The composite washout curves recorded during control conditions could be resolved into three monoexponential components. It is suggested that the steep initial slope (component I) is caused by the fraction of blood that perfuses the A-V anastomoses of the tongue. Components II and III appear to indicate the perfusion rate of lingual mucosa and musculature, respectively. The disappearance of component I due to the effect of epinephrine infusion might indicate the closure of arterio-venous anastomoses containing alpha receptors. Regitin pretreatment could prevent the closure of the arterio-venous anastomoses elicited by epinephrine infusion. The beta receptor stimulating activity of epinephrine might account for the augmentation of blood flow to lingual musculature. (orig.) 891 AJ/orig. 892 BRE [de

  3. Transforce lingual appliances pre-adjusted invisible appliances simplify treatment.

    Science.gov (United States)

    Clark, William John

    2011-01-01

    Transforce lingual appliances are designed to be used in conjunction with conventional fixed appliances. Lingual arch development is normally followed by bonded fixed appliances to detail the occlusion. Alternatively Transforce appliance treatment is an efficient method of preparing complex malocclusions prior to a finishing stage with invisible appliances. This approach is ideal for adult treatment, using light continuous forces for arch development with appliances that are comfortable to wear. Sagittal and Transverse appliances are designed for arch development in a range of sizes for contracted arches. They can be used to treat all classes of malocclusion and are pre-adjusted fixed/removable devices for non-compliance treatment. Force modules with nickel titanium coil springs enclosed in a tube deliver a gentle, biocompatible continuous force with a long range of action. They are excellent for mixed dentition and ideal for adult arch development. There are multiple sizes for upper and lower arch development and a sizing chart may be placed over a study model for correct selection, eliminating the need for laboratory work.

  4. SU-C-213-05: Evaluation of a Composite Copper-Plastic Material for a 3D Printed Radiation Therapy Bolus

    International Nuclear Information System (INIS)

    Vitzthum, L; Ehler, E; Sterling, D; Reynolds, T; Higgins, P; Dusenbery, K

    2015-01-01

    Purpose: To evaluate a novel 3D printed bolus fabricated from a copper-plastic composite as a thin flexible, custom fitting device that can replicate doses achieved with conventional bolus techniques. Methods: Two models of bolus were created on a 3D printer using a composite copper-PLA/PHA. Firstly, boluses were constructed at thicknesses of 0.4, 0.6 and 0.8 mm. Relative dose measurements were performed under the bolus with an Attix Chamber as well as with radiochromic film. Results were compared to superficial Attix Chamber measurements in a water equivalent material to determine the dosimetric water equivalence of the copper-PLA/PHA plastic. Secondly, CT images of a RANDO phantom were used to create a custom fitting bolus across the anterolateral scalp. Surface dose with the bolus placed on the RANDO phantom was measured with radiochromic film at tangential angles with 6, 10, 10 flattening filter free (FFF) and 18 MV photon beams. Results: Mean surface doses for 6, 10, 10FFF and 18 MV were measured as a percent of Dmax for the flat bolus devices of each thickness. The 0.4 mm thickness bolus was determined to be near equivalent to 2.5 mm depth in water for all four energies. Surface doses ranged from 59–63% without bolus and 85–90% with the custom 0.4 mm copper-plastic bolus relative to the prescribed dose for an oblique tangential beam arrangement on the RANDO phantom. Conclusion: Sub-millimeter thickness, 3D printed composite copper-PLA/PHA bolus can provide a build-up effect equivalent to conventional bolus. At this thickness, the 3D printed bolus allows a level of flexure that may provide more patient comfort than current 3D printing materials used in bolus fabrication while still retaining the CT based custom patient shape. Funding provided by an intra-department grant of the University of Minnesota Department of Radiation Oncology

  5. SU-C-213-05: Evaluation of a Composite Copper-Plastic Material for a 3D Printed Radiation Therapy Bolus

    Energy Technology Data Exchange (ETDEWEB)

    Vitzthum, L; Ehler, E; Sterling, D; Reynolds, T; Higgins, P; Dusenbery, K [University of Minnesota, Minneapolis, MN (United States)

    2015-06-15

    Purpose: To evaluate a novel 3D printed bolus fabricated from a copper-plastic composite as a thin flexible, custom fitting device that can replicate doses achieved with conventional bolus techniques. Methods: Two models of bolus were created on a 3D printer using a composite copper-PLA/PHA. Firstly, boluses were constructed at thicknesses of 0.4, 0.6 and 0.8 mm. Relative dose measurements were performed under the bolus with an Attix Chamber as well as with radiochromic film. Results were compared to superficial Attix Chamber measurements in a water equivalent material to determine the dosimetric water equivalence of the copper-PLA/PHA plastic. Secondly, CT images of a RANDO phantom were used to create a custom fitting bolus across the anterolateral scalp. Surface dose with the bolus placed on the RANDO phantom was measured with radiochromic film at tangential angles with 6, 10, 10 flattening filter free (FFF) and 18 MV photon beams. Results: Mean surface doses for 6, 10, 10FFF and 18 MV were measured as a percent of Dmax for the flat bolus devices of each thickness. The 0.4 mm thickness bolus was determined to be near equivalent to 2.5 mm depth in water for all four energies. Surface doses ranged from 59–63% without bolus and 85–90% with the custom 0.4 mm copper-plastic bolus relative to the prescribed dose for an oblique tangential beam arrangement on the RANDO phantom. Conclusion: Sub-millimeter thickness, 3D printed composite copper-PLA/PHA bolus can provide a build-up effect equivalent to conventional bolus. At this thickness, the 3D printed bolus allows a level of flexure that may provide more patient comfort than current 3D printing materials used in bolus fabrication while still retaining the CT based custom patient shape. Funding provided by an intra-department grant of the University of Minnesota Department of Radiation Oncology.

  6. SU-F-T-517: Determining the Tissue Equivalence of a Brass Mesh Bolus in a Reconstructed Chest Wall Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Shekel, E; Epstein, D; Levin, D [Dept of radiotherapy, Assuta Medical Centers, Tel Aviv (Israel)

    2016-06-15

    Purpose: To determine the tissue equivalence of a brass mesh bolus (RPD) in the setting of a reconstructed chest wall irradiation Methods: We measured breast skin dose delivered by a tangential field plan on an anthropomorphic phantom using Mosfet and nanoDot (Landauer) dosimeters in five different locations on the breast. We also measured skin dose using no bolus, 5mm and 10 mm superflab bolus. In the Eclipse treatment planning system (Varian, Palo Alto, CA) we calculated skin dose for different bolus thicknesses, ranging from 0 to 10 mm, in order to evaluate which calculation best matches the brass mesh measurements, as the brass mesh cannot be simulated due to artefacts.Finally, we measured depth dose behavior with the brass mesh bolus to verify that the bolus does not affect the dose to the breast itself beyond the build-up region. Results: Mosfet and nanoDot measurements were consistent with each other.As expected, skin dose measurements with no bolus had the least agreement with Eclipse calculation, while measurements for 5 and 10 mm agreed well with the calculation despite the difficulty in conforming superflab bolus to the breast contour. For the brass mesh the best agreement was for 3 mm bolus Eclipse calculation. For Mosfets, the average measurement was 90.8% of the expected dose, and for nanoDots 88.33% compared to 83.34%, 88.64% and 93.94% (2,3 and 5 mm bolus calculation respectively).The brass mesh bolus increased skin dose by approximately 25% but there was no dose increase beyond the build-up region. Conclusion: Brass mesh bolus is most equivalent to a 3 mm bolus, and does not affect the dose beyond the build-up region. The brass mesh cannot be directly calculated in Eclipse, hence a 3mm bolus calculation is a good reflection of the dose response to the brass mesh bolus.

  7. Comparison of lingual tonsil size as depicted on MR imaging between children with obstructive sleep apnea despite previous tonsillectomy and adenoidectomy and normal controls

    Energy Technology Data Exchange (ETDEWEB)

    Fricke, Bradley L. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States); Emory University School of Medicine, Department of Radiology, Atlanta, GA (United States); Donnelly, Lane F. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States); Cincinnati Children' s Hospital Medical Center, Department of Pediatrics, Cincinnati, OH (United States); Shott, Sally R. [Cincinnati Children' s Hospital Medical Center, Division of Otolaryngology, Cincinnati, OH (United States); Kalra, Maninder; Poe, Stacy A.; Chini, Barbara A.; Amin, Raouf S. [Cincinnati Children' s Hospital Medical Center, Department of Pediatrics, Cincinnati, OH (United States)

    2006-06-15

    Cine MRI has become a useful tool in the evaluation of patients with persistent obstructive sleep apnea (OSA) despite previous surgical intervention and in patients with underlying conditions that render them susceptible to multilevel airway obstruction. Findings on cine MRI studies have also increased our understanding of the mechanisms and anatomic causes of OSA in children. To compare lingual tonsil size between children with OSA and a group of normal controls. In addition, a subanalysis was made of the group of children with OSA comparing lingual tonsils between children with and without underlying Down syndrome. Children with persistent OSA despite previous palatine tonsillectomy and adenoidectomy and controls without OSA underwent MR imaging with sagittal fast spin echo inversion-recovery images, and lingual tonsils were categorized as nonperceptible at imaging or present and measurable. When present, lingual tonsils were measured in the maximum anterior-posterior diameter. If lingual tonsils were greater than 10 mm in diameter and abutting both the posterior border of the tongue and the posterior pharyngeal wall, they were considered markedly enlarged. There were statistically significant differences between the OSA and control groups for the presence vs. nonvisualization of lingual tonsils (OSA 33% vs. control 0%, P=0.0001) and mean diameter of the lingual tonsils (OSA 9.50 mm vs. control 0.0 mm, P=0.00001). Within the OSA group, there were statistically significant differences between children with and without Down syndrome for the three lingual tonsil width categories (P=0.0070) and occurrence of markedly enlarged lingual tonsils (with Down syndrome 35% vs. without Down syndrome 3%, P=0.0035). Enlargement of the lingual tonsils is relatively common in children with persistent obstructive sleep apnea after palatine tonsillectomy and adenoidectomy. This is particularly true in patients with Down syndrome. (orig.)

  8. Comparison of lingual tonsil size as depicted on MR imaging between children with obstructive sleep apnea despite previous tonsillectomy and adenoidectomy and normal controls

    International Nuclear Information System (INIS)

    Fricke, Bradley L.; Donnelly, Lane F.; Shott, Sally R.; Kalra, Maninder; Poe, Stacy A.; Chini, Barbara A.; Amin, Raouf S.

    2006-01-01

    Cine MRI has become a useful tool in the evaluation of patients with persistent obstructive sleep apnea (OSA) despite previous surgical intervention and in patients with underlying conditions that render them susceptible to multilevel airway obstruction. Findings on cine MRI studies have also increased our understanding of the mechanisms and anatomic causes of OSA in children. To compare lingual tonsil size between children with OSA and a group of normal controls. In addition, a subanalysis was made of the group of children with OSA comparing lingual tonsils between children with and without underlying Down syndrome. Children with persistent OSA despite previous palatine tonsillectomy and adenoidectomy and controls without OSA underwent MR imaging with sagittal fast spin echo inversion-recovery images, and lingual tonsils were categorized as nonperceptible at imaging or present and measurable. When present, lingual tonsils were measured in the maximum anterior-posterior diameter. If lingual tonsils were greater than 10 mm in diameter and abutting both the posterior border of the tongue and the posterior pharyngeal wall, they were considered markedly enlarged. There were statistically significant differences between the OSA and control groups for the presence vs. nonvisualization of lingual tonsils (OSA 33% vs. control 0%, P=0.0001) and mean diameter of the lingual tonsils (OSA 9.50 mm vs. control 0.0 mm, P=0.00001). Within the OSA group, there were statistically significant differences between children with and without Down syndrome for the three lingual tonsil width categories (P=0.0070) and occurrence of markedly enlarged lingual tonsils (with Down syndrome 35% vs. without Down syndrome 3%, P=0.0035). Enlargement of the lingual tonsils is relatively common in children with persistent obstructive sleep apnea after palatine tonsillectomy and adenoidectomy. This is particularly true in patients with Down syndrome. (orig.)

  9. A custom three-dimensional electron bolus technique for optimization of postmastectomy irradiation

    International Nuclear Information System (INIS)

    Perkins, George H.; McNeese, Marsha D.; Antolak, John A.; Buchholz, Thomas A.; Strom, Eric A.; Hogstrom, Kenneth R.

    2001-01-01

    Purpose: Postmastectomy irradiation (PMI) is a technically complex treatment requiring consideration of the primary tumor location, possible risk of internal mammary node involvement, varying chest wall thicknesses secondary to surgical defects or body habitus, and risk of damaging normal underlying structures. In this report, we describe the application of a customized three-dimensional (3D) electron bolus technique for delivering PMI. Methods and Materials: A customized electron bolus was designed using a 3D planning system. Computed tomography (CT) images of each patient were obtained in treatment position and the volume to be treated was identified. The distal surface of the wax bolus matched the skin surface, and the proximal surface was designed to conform to the 90% isodose surface to the distal surface of the planning target volume (PTV). Dose was calculated with a pencil-beam algorithm correcting for patient heterogeneity. The bolus was then fabricated from modeling wax using a computer-controlled milling device. To aid in quality assurance, CT images with the bolus in place were generated and the dose distribution was computed using these images. Results: This technique optimized the dose distribution while minimizing irradiation of normal tissues. The use of a single anterior field eliminated field junction sites. Two patients who benefited from this option are described: one with altered chest wall geometry (congenital pectus excavatum), and one with recurrent disease in the medial chest wall and internal mammary chain (IMC) area. Conclusion: The use of custom 3D electron bolus for PMI is an effective method for optimizing dose delivery. The radiation dose distribution is highly conformal, dose heterogeneity is reduced compared to standard techniques in certain suboptimal settings, and excellent immediate outcome is obtained

  10. Changes in the oral environment after placement of lingual and labial orthodontic appliances.

    Science.gov (United States)

    Lombardo, Luca; Ortan, Yildiz Öztürk; Gorgun, Özge; Panza, Chiara; Scuzzo, Giuseppe; Siciliani, Giuseppe

    2013-09-11

    This study compared the oral hygiene and caries risk of patients treated with labial and lingual orthodontic appliances throughout a prospective evaluation of the status of the oral environment before and after bracket placement. A total of 20 orthodontic patients aged 19 to 23 years were included in the study and were divided into two groups: 10 patients wore Roth labial appliance (American Orthodontics, Sheboygan, WI, USA) and 10 patients wore STb lingual appliance (Ormco Corporation, Glendora, CA, USA). Plaque index (PI), gingival bleeding index (GBI), salivary flow rate, saliva buffer capacity, salivary pH, and Streptococcus mutans and Lactobacillus counts in saliva were determined at three time points: before orthodontic appliance placement (T0), 4 weeks after bonding (T1), and 8 weeks after bonding (T2). After appliance placement, all patients were periodically educated to the oral hygiene procedures. Wilcoxon rank and Mann-Whitney U tests were used to determine intragroup and intergroup differences as regards qualitative data. To compare quantitative data between the groups, chi-square and Fisher's exact tests were undertaken, while intragroup differences were tested with McNemar test. The level of statistical significance was set at pappliance. The GBI value increased significantly between T0 and T1 but decreased significantly between T1 and T2 (pappliance. S. mutans counts increased significantly between T0 and T2 in the saliva samples of patients treated with lingual appliance. No statistically significant differences were found between S. mutans and Lactobacillus counts at the three terms of saliva collection in patients treated with labial appliance. No statistically significant differences were found between the two groups at the three time points as regards the salivary flow rate and saliva buffer capacity. Lingual and labial orthodontic appliances showed a different potential in modifying the investigated clinical parameters: patients wearing STb

  11. Effects of a sour bolus on the intramuscular electromyographic (EMG) activity of muscles in the submental region.

    Science.gov (United States)

    Palmer, Phyllis M; McCulloch, Timothy M; Jaffe, Debra; Neel, Amy T

    2005-01-01

    A sour bolus has been used as a modality in the treatment of oropharyngeal dysphagia based on the hypothesis that this stimulus provides an effective preswallow sensory input that lowers the threshold required to trigger a pharyngeal swallow. The result is a more immediate swallow onset time. Additionally, the sour bolus may invigorate the oral muscles resulting in stronger contractions during the swallow. The purpose of this investigation was to compare the intramuscular electromyographic activity of the mylohyoid, geniohyoid, and anterior belly of the digastric muscles during sour and water boluses with regard to duration, strength, and timing of muscle activation. Muscle duration, swallow onset time, and pattern of muscle activation did not differ for the two bolus types. Muscle activation time was more tightly approximated across the onsets of the three muscles when a sour bolus was used. A sour bolus also resulted in a stronger muscle contraction as evidenced by greater electromyographic activity. These data support the use of a sour bolus as part of a treatment paradigm.

  12. Comparison of the force levels among labial and lingual self-ligating and conventional brackets in simulated misaligned teeth.

    Science.gov (United States)

    Alobeid, Ahmad; El-Bialy, Tarek; Khawatmi, Said; Dirk, Cornelius; Jäger, Andreas; Bourauel, Christoph

    2017-08-01

    The aim of this study was to evaluate force levels exerted by levelling arch wires with labial and lingual conventional and self-ligating brackets. The tested orthodontic brackets were of the 0.022-in slot size for labial and 0.018-in for lingual brackets and were as follows: 1. Labial brackets: (i) conventional bracket (GAC-Twin, Dentsply), (ii) passive self-ligating (SL) brackets (Damon-Q®, ORMCO; Ortho classic H4™, Orthoclassic; FLI®SL, Rocky Mountain Orthodontics) and (iii) active SL brackets (GAC In-Ovation®C, DENTSPLY and SPEED™, Strite). 2. Lingual brackets: (i) conventional brackets (Incognito, 3M and Joy™, Adenta); (ii) passive SL bracket (GAC In-Ovation®LM™, Dentsply and (iii) active SL bracket (Evolution SLT, Adenta). Thermalloy-NiTi 0.013-in and 0.014-in arch wires (Rocky Mountain Orthodontics) were used with all brackets. The simulated malocclusion represented a maxillary central incisor displaced 2 mm gingivally (x-axis) and 2 mm labially (z-axis). Lingual bracket systems showed higher force levels (2.4 ± 0.2 to 3.8 ± 0.2 N) compared to labial bracket systems (from 1.1 ± 0.1 to 2.2 ± 0.4 N). However, the differences between SL and conventional bracket systems were minor and not consistent (labial brackets: 1.2 ± 0.1 N for the GAC Twin and 1.1 ± 0.1 to 1.6 ± 0.1 N for the SL brackets with 0.013-in thermalloy; lingual brackets: 2.5 ± 0.2 to 3.5 ± 0.1 N for the conventional and 2.7 ± 0.3 to 3.4 ± 0.1 N for the SL brackets with 0.013-in Thermalloy). This is an in vitro study with different slot sizes in the labial and lingual bracket systems, results should be interpreted with caution. Lingual bracket systems showed higher forces compared to labial bracket systems that might be of clinical concern. We recommend highly flexible nickel titanium arch wires lower than 0.013-in for the initial levelling and alignment especially with lingual appliances. © The Author 2017. Published by Oxford University Press on behalf of the European

  13. A hazard of lingual orthodontic attachments: a case report.

    Science.gov (United States)

    Oliver, Graham; Borumandi, Farzad

    2015-01-01

    A case is presented of an unusual trauma to the floor of mouth caused by an unused lingual orthodontic button. This resulted in a vein being stripped from the floor of mouth and was associated with severe pain and restricted tongue movement. Management was by ligation and excision of the loop of the vessel under local anaesthesia.

  14. Soft-robotic esophageal swallowing as a clinically-inspired bolus rheometry technique

    International Nuclear Information System (INIS)

    Dirven, Steven; Allen, Jacqueline; Xu, Weiliang; Cheng, Leo K

    2017-01-01

    To investigate the impact of viscosity and peristaltic transport parameters on manometric pressure signatures, a reproducible swallowing process is required. Due to inter- and intra-subject variability from swallow to swallow, the human body does not represent an optimal mechanism for such an investigation. A smooth and continuous swallowing soft-robot has been developed to produce biomimetic swallowing trajectories, and is proposed to operate as a bench-top bolus rheometric investigation method. The method compares conventional viscometry and pressure signature findings from robotic swallowing experiments. The robotic aspect of experimentation involved 450 biomimetic swallows (10 repetitions of 45 unique experiments). The method examined swallowing transport in three dimensions: bolus formulation, peristaltic wavelength, and peristaltic velocity, each of which are known to contribute to safe and effective swallowing in vivo . It is found that the pressure gradients and magnitudes are commensurate with clinical reports on biological swallowing, on the order of 100 mmHg peak, however, the relationship between viscosity and pressure signatures is less clear. Bolus transport cannot be predicted as a function of bolus viscosity alone. Traditional viscometric data at 50 s −1 , as used in clinical practice, may not be a strong indicator of swallow effort, safety, or efficacy in vivo . (paper)

  15. EFFECT OF A BITTER BOLUS ON ORAL, PHARYNGEAL AND ESOPHAGEAL TRANSIT OF HEALTHY SUBJECTS

    Directory of Open Access Journals (Sweden)

    Leda Maria Tavares ALVES

    2013-03-01

    Full Text Available Context During swallowing, boluses stimulate sensory receptors of the oral, pharyngeal, laryngeal, and esophageal regions. Sweet and tasteless foods are more acceptable for swallowing than bitter foods. A bitter bolus is unpleasant for most subjects. Our hypothesis was that the ingestion of a bitter bolus might alter the oral behavior, pharyngeal and esophageal transit when compared to a sweet bolus. Objective To evaluate whether the bitter taste of a liquid bolus causes alteration on oral, pharyngeal and/or esophageal transit in normal subjects in comparison with sweet bolus.' Method Scintigraphic evaluation of oral, pharyngeal and esophageal transit was performed in 43 asymptomatic subjects, 22 women and 21 men, ages 23-71 years, without problems with the ingestion of liquid and solid foods, and without digestive, cardiac or neurologic diseases. Each subject swallowed in random sequence and at room temperature 5 mL of a liquid bolus with bitter taste, prepared with 50 mL of water with 2 g of leaves of Peumus boldus, heated until boiling (boldus tea, and 5 mL of a liquid bolus with sweet taste, prepared with 50 mL of water with 3 g of sucrose, both labeled with 37 MBq of technetium phytate (Tc99m. Results There was no difference between the bitter bolus and the sweet bolus in mouth, pharynx and esophageal transit and clearance duration and in the amount of residues. Conclusion A bitter bolus, considered an unpleasant bolus, does not alter the duration of oral, pharyngeal and esophageal phases of swallowing, when compared with a sweet bolus, considered a pleasant bolus. Contexto Durante a deglutição o bolo estimula os receptores sensoriais da boca, faringe, laringe e esôfago. Os alimentos doces e sem gosto são mais aceitáveis para a deglutição do que os alimentos amargos, que tem gosto desagradável para a maioria dos indivíduos. A hipótese destes autores era que a ingestão de um bolo amargo pode alterar o trânsito oral

  16. Customized lingual bracket system and skeletal anchorage system for open bite correction

    Directory of Open Access Journals (Sweden)

    Toru Inami

    2016-01-01

    Full Text Available We treated a female patient with open bite and high-angle Class II Division 2 malocclusion using fully customized lingual appliances, orthodontic anchor screws (OAS, and a skeletal anchorage system (SAS. By carefully controlling torque, anchorage, and vertical skeletal and dental factors, we were able to obtain proper anterior coupling. Even after the retention phase of treatment, the occlusion was maintained, indicating that we provided proper treatment according to the properly designed treatment plan. This also indicates that cases with an extremely high level of difficulty, as in the present case with high-angle retrognathic mandible and open bite, can be treated by combining the Incognito appliance (a fully customized lingual bracket appliance with a SAS and OAS.

  17. Sci—Thur AM: YIS - 07: Design and production of 3D printed bolus for electron radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Su, Shiqin [Department of Physics and Atmospheric Science, Dalhousie University, Halifax, Nova Scotia (Canada); Moran, Kathryn [Queen Elizabeth II Health Sciences Centre, Nova Scotia Cancer Centre, Halifax, Nova Scotia (Canada); Robar, James L. [Department of Physics and Atmospheric Science, Dalhousie University, Halifax, Nova Scotia (Canada); Department of Radiation Oncology, Dalhousie University, Halifax, Nova Scotia (Canada)

    2014-08-15

    This is a proof-of-concept study demonstrating the capacity for modulated electron radiation therapy (MERT) using 3D printed bolus. Previous reports have involved bolus design using an electron pencil beam model and fabrication using a milling machine. In this study, an in-house algorithm is presented that optimizes the dose distribution with regard to dose coverage, conformity and homogeneity within planning target volume (PTV). The algorithm uses calculated result of a commercial electron Monte Carlo dose calculation as input. Distances along ray lines from distal side of 90% isodose to distal surface of PTV are used to estimate the bolus thickness. Inhomogeneities within the calculation volume are accounted for using coefficient of equivalent thickness method. Several regional modulation operators are applied to improve dose coverage and uniformity. The process is iterated (usually twice) until an acceptable MERT plan is realized, and the final bolus is printed using solid polylactic acid. The method is evaluated with regular geometric phantoms, anthropomorphic phantoms and a clinical rhabdomyosarcoma pediatric case. In all cases the dose conformity is improved compared to that with uniform bolus. The printed boluses conform well to the surface of complex anthropomorphic phantoms. For the rhabdomyosarcoma patient, the MERT plan yields a reduction of mean dose by 38.2% in left kidney relative to uniform bolus. MERT using 3D printed bolus appears to be a practical, low cost approach to generating optimized bolus for electron therapy. The method is effective in improving conformity of prescription isodose surface and in sparing immediately adjacent normal tissues.

  18. Sci—Thur AM: YIS - 07: Design and production of 3D printed bolus for electron radiation therapy

    International Nuclear Information System (INIS)

    Su, Shiqin; Moran, Kathryn; Robar, James L.

    2014-01-01

    This is a proof-of-concept study demonstrating the capacity for modulated electron radiation therapy (MERT) using 3D printed bolus. Previous reports have involved bolus design using an electron pencil beam model and fabrication using a milling machine. In this study, an in-house algorithm is presented that optimizes the dose distribution with regard to dose coverage, conformity and homogeneity within planning target volume (PTV). The algorithm uses calculated result of a commercial electron Monte Carlo dose calculation as input. Distances along ray lines from distal side of 90% isodose to distal surface of PTV are used to estimate the bolus thickness. Inhomogeneities within the calculation volume are accounted for using coefficient of equivalent thickness method. Several regional modulation operators are applied to improve dose coverage and uniformity. The process is iterated (usually twice) until an acceptable MERT plan is realized, and the final bolus is printed using solid polylactic acid. The method is evaluated with regular geometric phantoms, anthropomorphic phantoms and a clinical rhabdomyosarcoma pediatric case. In all cases the dose conformity is improved compared to that with uniform bolus. The printed boluses conform well to the surface of complex anthropomorphic phantoms. For the rhabdomyosarcoma patient, the MERT plan yields a reduction of mean dose by 38.2% in left kidney relative to uniform bolus. MERT using 3D printed bolus appears to be a practical, low cost approach to generating optimized bolus for electron therapy. The method is effective in improving conformity of prescription isodose surface and in sparing immediately adjacent normal tissues

  19. Determining shapes and dimensions of dental arches for the use of straight-wire arches in lingual technique

    Directory of Open Access Journals (Sweden)

    Silvana Allegrini Kairalla

    2014-10-01

    Full Text Available INTRODUCTION: This study aims to determine the shape and dimension of dental arches from a lingual perspective, and determine shape and size of a straight archwire used for lingual Orthodontics. METHODS: The study sample comprised 70 Caucasian Brazilian individuals with normal occlusion and at least four of Andrew's six keys. Maxillary and mandibular dental casts were digitized (3D and the images were analyzed by Delcam Power SHAPET 2010 software. Landmarks on the lingual surface of teeth were selected and 14 measurements were calculated to determine the shape and size of dental arches. RESULTS: Shapiro-Wilk test determined small arch shape by means of 25th percentile (P25% - an average percentile for the medium arch; and a large one determined by means of 75th percentile (P75%. T-test revealed differences between males and females in the size of 12 dental arches. CONCLUSION: The straight-wire arch shape used in the lingual straight wire technique is a parabolic-shaped arch, slightly flattened on its anterior portion. Due to similarity among dental arch sizes shown by males and females, a more simplified diagram chart was designed.

  20. The Interactive Effect of Diabetes Family Conflict and Depression on Insulin Bolusing Behaviors for Youth.

    Science.gov (United States)

    Maliszewski, Genevieve; Patton, Susana R; Midyett, L Kurt; Clements, Mark A

    2017-05-01

    Adherence to type 1 diabetes management declines as children enter adolescence. For youth, psychosocial variables including mood and interpersonal relationships play a large role in diabetes maintenance. The current study assessed the unique and interactive roles diabetes family conflict and depression have on insulin bolusing behaviors for youth ages 10-16 years. Ninety-one youth-parent dyads completed a survey assessing family conflict and depression. Mean daily blood glucose levels, mealtime insulin bolus scores ( BOLUS), and glycated hemoglobin (HbA1c) were collected from the medical record as outcome variables. Parent-reported diabetes-related family conflict and youths' endorsed depression both significantly predicted insulin bolusing behavior, R 2 = .13, F(2, 88) = 6.66, P family conflict and youth depression played a significant role in youths' bolusing behaviors, above and beyond that which was predicted by conflict and depression separately, R 2 = .18, F change (1, 87) = 4.63, P family conflict, while there was no change in BOLUS scores among depressed youth living in families reporting less conflict. Findings underscore the importance of screening for depression and family conflict in youth experiencing or at risk for poor adherence to mealtime insulin and higher HbA1c levels.

  1. Pre-pharyngeal swallow effects of recurrent laryngeal nerve lesion on bolus shape and airway protection in an infant pig model

    Science.gov (United States)

    Gould, Francois D. H.; Yglesias, B.; Ohlemacher, J.; German, R. Z.

    2016-01-01

    Recurrent laryngeal nerve (RLN) damage in infants leads to increased dysphagia and aspiration pneumonia. Recent work has shown that intra oral transport and swallow kinematics change following RLN lesion, suggesting potential changes in bolus formation prior to the swallow. In this study we used geometric morphometrics to understand the effect of bolus shape on penetration and aspiration in infants with and without RLN lesion. We hypothesized 1) that geometric bolus properties are related to airway protection outcomes and 2) that in infants with RLN lesion, the relationship between geometric bolus properties and dysphagia is changed. In five infant pigs, dysphagia in 188 swallows was assessed using the Infant Mammalian Penetration Aspiration Score (IMPAS). Using images from high-speed VFSS, bolus shape, bolus area, and tongue outline were quantified digitally. Bolus shape was analyzed using elliptical Fourier analysis, and tongue outline using polynomial curve fitting. Despite large inter-individual differences, significant within individual effects of bolus shape and bolus area on airway protection exist. The relationship between penetration-aspiration score and both bolus area and shape changed post lesion. Tongue shape differed between pre and post lesion swallows, and between swallows with different IMPAS scores. Bolus shape and area affect airway protection outcomes. RLN lesion changes that relationship, indicating that proper bolus formation and control by the tongue requires intact laryngeal sensation. The impact of RLN lesion on dysphagia is pervasive. PMID:27873091

  2. A Study on the Necessary Number of Bolus Treatments in Radiotherapy after Modified Radical Mastectomy

    International Nuclear Information System (INIS)

    Hong, Chae Seon; Kim, Jong Sik; Kim, Young Kon; Park, Young Hwan

    2006-01-01

    Post-mastectomy radiotherapy (PMR) is known to decrease loco-regional recurrence. Adequate skin and dermal dose are achieved by adding bolus. The more difficult clinical issue is determining the necessary number of bolus treatment, given the limits of normal skin tolerance. The aim of this study is to evaluate the necessary number of bolus treatment after PMR in patients with breast cancer. Four female breast cancer patients were included in the study. The median age was 53 years(range, 38-74), tumor were left sided in 2 patients and right sided in 2 patients. All patients were treated with postoperative radiotherapy after MRM. Radiotherapy was delivered to the chest wall (C.W) and supraclavicular lymph nodes (SCL) using 4 MV X-ray. The total dose was 50 Gy, in 2 Gy fractions (with 5 times a week). CT was performed for treatment planning, treatment planning was performed using A DAC-Pinnacles 3 (Phillips, USA) for all patients without and with bolus. Bolus treatment plans were generated using image tool (0.5 cm of thickness and 6 cm of width). Dose distribution was analyzed and the increased skin dose rate in the build-up region was computed and the skin dose using TLD-100 chips (Harshaw, USA) was measured. No significant difference was found in dose distribution without and with bolus; C.W coverage was 95-100% of the prescribed dose in both. But, there was remarkable difference in the skin dose to the scar. The skin dose to the scar without and with bolus were 100-105% and 50-75%. The increased skin dose rates in the build-up region for Pt. 1, Pt. 2. Pt. 3 and Pt. 4 were 23.3%, 35.6%, 34.9%, and 41.7%. The results of measured skin dose using TLD-100 chips in the cases without and with bolus were 209.3 cGy and 161.1 cGy, 200 cGy and 150.2 cGy, 211.4 cGy and 160.5 cGy, 198.6 cGy and 155.5 cGy for Pt. 1, Pt. 2, Pt. 3, and Pt. 4. It was concludes through this analysis that the adequate number of bolus treatments is 50-60% of the treatment program. Further, clinical

  3. Cross-lingual parser selection for low-resource languages

    DEFF Research Database (Denmark)

    Agic, Zeljko

    2017-01-01

    In multilingual dependency parsing, transferring delexicalized models provides unmatched language coverage and competitive scores, with minimal requirements. Still, selecting the single best parser for any target language poses a challenge. Here, we propose a lean method for parser selection. It ....... It offers top performance, and it does so without disadvantaging the truly low-resource languages. We consistently select appropriate source parsers for our target languages in a realistic cross-lingual parsing experiment....

  4. Outcome assessment of lingual and labial appliances compared with cephalometric analysis, peer assessment rating, and objective grading system in Angle Class II extraction cases.

    Science.gov (United States)

    Deguchi, Toru; Terao, Fumie; Aonuma, Tomo; Kataoka, Tomoki; Sugawara, Yasuyo; Yamashiro, Takashi; Takano-Yamamoto, Teruko

    2015-05-01

    To validate our hypothesis that there would be significant differences in treatment outcomes, including cephalometric values, degree of root resorption, occlusal indices, and functional aspect, between cases treated with labial and lingual appliances. Twenty-four consecutively treated Class II cases with extractions and lingual appliance were compared with 25 matched cases treated with extraction and labial appliance. Orthodontic treatment outcomes were evaluated by cephalometric analysis, peer assessment rating, and an objective grading system (OGS). Additionally, functional analysis was also performed in both groups after orthodontic treatment. Statistical comparison was performed using the Wilcoxon signed rank test within the groups, and the Mann-Whitney U-test was used to compare between the labial and lingual groups. The only significant difference between the groups was that the interincisal angle was larger in the lingual group than in the labial group. OGS evaluation showed that control over root angulation was significantly worse in the lingual group than in the labial group. There was no significant difference between groups in the amount of root resorption or in functional evaluation. Generally, lingual appliances offer comparable treatment results to those obtained with labial appliances. However, care should be taken with lingual appliances because they are more prone to produce uprighted incisors and root angulation.

  5. Custom bolus of hydrogel: dosimetric characterization, clinical use and placement uncertainties; Bolus de compensación personalizado de hidrogel: Caracterización radiológica, uso clínico e incertidumbre de colocación

    Energy Technology Data Exchange (ETDEWEB)

    Pérez-García, H.; Antón, D.; Miguel, D.; Ángel del Castillo, D.; Alonso, D.; De Frutos, J.; Pérez, C.

    2017-11-01

    When using electron beams over irregular surfaces it shows remarkable dose heterogeneity in target tissue, the use of a hydrogel bolus by Varihesive® ConvaTec as a custom bolus is proposed to compensate this effect. Radiological characterization is carried out comparing hydrogel with water by a CT study and by measuring percentage depth dose for electron beams. The dosimetric impact due to the uncertainty of bolus placement is quantitatively evaluated and it is concluded that the use of hydrogel is an acceptable solution as compensation bolus with radiological properties similar to water. [Spanish] La incidencia de un campo de electrones en una superficie irregular produce distribuciones heterogéneas de dosis. En este trabajo se propone el uso de un bolus personalizado de hidrogel Varihesive® de ConvaTec para compensar dichas irregularidades. El hidrogel se caracteriza radiológicamente comparándolo con agua mediante una adquisición TC y se obtiene el porcentaje de dosis en profundidad para campos de electrones. Se evalúa cuantitativamente el impacto dosimétrico debido a la incertidumbre de colocación y se concluye que el uso de hidrogel resulta una solución aceptable como bolus de compensación con propiedades radiológicas similares al agua.

  6. Endoscopic evaluation of food bolus formation and its relationship with the number of chewing cycles.

    Science.gov (United States)

    Fukatsu, H; Nohara, K; Kotani, Y; Tanaka, N; Matsuno, K; Sakai, T

    2015-08-01

    It is known that solid food is transported to the pharynx actively in parallel to it being crushed by chewing and mixed with saliva in the oral cavity. Therefore, food bolus formation should be considered to take place from the oral cavity to the pharynx. In previous studies, the chewed food was evaluated after the food had been removed from the oral cavity. However, it has been pointed out that spitting food out of the oral cavity interferes with natural food bolus formation. Therefore, we observed food boluses immediately before swallowing using an endoscope to establish a method to evaluate the food bolus-forming function, and simultaneously performed endoscopic evaluation of food bolus formation and its relationship with the number of chewing cycles. The subject was inserted the endoscope nasally and instructed to eat two coloured samples of boiled rice simultaneously in two ingestion conditions ('as usual' and 'chewing well'). The condition of the food bolus was graded into three categories for each item of grinding, mixing and aggregation and scored 2, 1 and 0. The score of aggregation was high under both ingestion conditions. The scores of grinding and mixing tended to be higher in subjects with a high number of chewing cycles, and the score of aggregation was high regardless of the number of chewing cycles. It was suggested that food has to be aggregated, even though the number of chewing cycles is low and the food is not ground or mixed for a food bolus to reach the swallowing threshold. © 2015 John Wiley & Sons Ltd.

  7. Gray Matter Volume of the Lingual Gyrus Mediates the Relationship between Inhibition Function and Divergent Thinking

    Directory of Open Access Journals (Sweden)

    Lijie Zhang

    2016-10-01

    Full Text Available Abstract: Although previous research provides converging evidence for the role of posterior regions of the brain (including temporal, occipital, and parietal regions involved in inhibition on creative thinking, it remains unclear as to how these regions influence individual differences in creative thinking. Thus, we explored the relationship between posterior regions (i.e., hippocampal, parahippocampal, lingual gyrus, precuneus, and cuneus , inhibition function, and divergent thinking in 128 healthy college students. The results revealed that lower inhibition was associated with larger gray matter volume (GMV in the lingual gyrus, which in turn was associated with higher divergent thinking. In addition, GMV in the lingual gyrus mediated the association between inhibition and divergent thinking. These results provide new evidence for the role of inhibition in creative thinking. Inhibition may affect the amount of information stored in long-term memory, which, in turn influences divergent thinking.

  8. Propulsion Systems Panel deliberations

    Science.gov (United States)

    Bianca, Carmelo J.; Miner, Robert; Johnston, Lawrence M.; Bruce, R.; Dennies, Daniel P.; Dickenson, W.; Dreshfield, Robert; Karakulko, Walt; Mcgaw, Mike; Munafo, Paul M.

    1993-01-01

    The Propulsion Systems Panel was established because of the specialized nature of many of the materials and structures technology issues related to propulsion systems. This panel was co-chaired by Carmelo Bianca, MSFC, and Bob Miner, LeRC. Because of the diverse range of missions anticipated for the Space Transportation program, three distinct propulsion system types were identified in the workshop planning process: liquid propulsion systems, solid propulsion systems and nuclear electric/nuclear thermal propulsion systems.

  9. Cineradiography of the liquid bolus swallow. A study of the speed ot the bolus and peristaltic wave and of movement of the hyoid bone, larynx, and epiglottis

    International Nuclear Information System (INIS)

    Sundgren, P.

    1991-01-01

    In the evaluation of the dysphagic patient, radiology is crucial as a technique for monitoring morphology and function. In particular, high-speed cineradiography can reveal a variety of pharyngeal dysfunctions. However, in the literature and in practice the difference between normal and abnormal function is not always clear. This monography is based on high-speed cineradiographies of swallowing in 75 non-dysphagic volunteers and in 189 dysphagic patients. The purpose was to study whether differences in bolus volumes, patient position, age and gender had any effects on the following parameters: the speed of the peristaltic wave and apex of the liquid barium bolus, the length of movement and the movement pattern of the hyoid bone and larynx, and epiglottic function. The study disclosed that the speed of the bolus, the anterior-superior movement and net movement of the hyoid bone increased significantly with larger bolus volumes. The position of the individual in relation to gravity significantly influenced the speed of peristalsis. In most of the measured parameters there were no differences between non-dysphagic and dysphagic individuals expect for differences in the intrapersonal variations and in the anterior-superior movement of the hyoid bone. In patients with pharyngeal dysfunction the initial stage of the elevation of the larynx was significantly lower than in patients without dysfunction. The approximation of the thyroid cartilage to the hyoid bone was significantly greater in individuals with normal epiglottic function than in those with epiglottic dysmobility. It is suggested that abnormal speed of peristalsis may be a mild form of dysfunction. Measurements of the aforementioned speed and movements can be done if bolus volume, age and position of the patient, film speed and magnifications factors are known. Hypotheses concerning epiglottic function and central control of swallowing are proposed. (au)

  10. Use of a marshmallow bolus for evaluating lower esophageal mucosal rings.

    Science.gov (United States)

    Ott, D J; Kelley, T F; Chen, M Y; Gelfand, D W; Wu, W C

    1991-07-01

    Sixty-three patients (35 women, 28 men; mean age 55 yr) with lower esophageal mucosal ring shown radiographically were examined with a semi-solid bolus consisting of a portion of a standard marshmallow. The most common symptom was dysphagia, present in 46 (73%) patients. Impaction of the marshmallow bolus by the ring occurred in 40 (63%) of the 63 patients, and produced symptoms in 27 (68%) of these 40 patients. Nine (14%) rings were detected radiographically only with a solid bolus; eight of these patients had dysphagia and seven rings were 20 mm or less in caliber. Impaction related to ring caliber, and was found in all 17 (100%) rings that were 13 mm or less in diameter, in 17/24 (71%) 14- to 19-mm rings, and in 6/22 (27%) rings 20 mm or more in caliber. Endoscopy in 23 patients detected 16 (70%) rings, and also depended on ring caliber: less than or equal to 13 mm, 6/6 (100%); 14-19 mm, 5/9 (56%); greater than or equal to 20 mm, 5/8 (63%). Marshmallow impaction occurred in 17 (74%) of 23 patients who had endoscopy; three of the 23 patients had normal endoscopy. In conclusion, radiographic examination supplemented by the use of a marshmallow bolus best detects lower esophageal mucosal ring.

  11. One-stage lingual augmented urethroplasty in repair of distal penile ...

    African Journals Online (AJOL)

    E. Elsayed

    Abstract. Objectives: To evaluate the outcome of augmentation of shallow urethral plate by lingual graft in repair of distal penile hypospadias. Patients and methods: Between June 2008 and May 2011, the procedure was performed on 23 patients with mean age 2.3 years (range 1–3). All patients had distal penile ...

  12. The impact of mastication, salivation and food bolus formation on salt release during bread consumption.

    Science.gov (United States)

    Tournier, Carole; Grass, Manon; Septier, Chantal; Bertrand, Dominique; Salles, Christian

    2014-11-01

    Health authorities recommend higher fibre and lower salt content in bread products. However, these basic ingredients of bread composition are multifunctional, and important changes in their content influence the texture, flavour and acceptability of the product. This study was designed to investigate the link between oral processing, bolus formation and sodium release during the consumption of four different breads that varied in composition and structure. Chewing behaviour was determined by surface electromyography, and salivation was quantified from the water content of the boluses collected. The kinetics of bread degradation during food bolus formation was characterised by measuring the bolus heterogeneity by texture image analysis, and sodium release into the saliva was quantified. Mastication and salivation varied between products and between subjects, thus highlighting different bolus formation strategies. In vivo salt release was mainly explained by mastication parameters. The initial slope of sodium release increased when the chewing muscles' activity increased, and the maximum sodium concentration was reached later when more masticatory cycles were required to reach the swallowing point.

  13. A comparison of pain experienced by patients treated with labial and lingual orthodontic appliances.

    Science.gov (United States)

    Wu, Abby K Y; McGrath, Colman; Wong, Ricky W K; Wiechmann, D; Rabie, A Bakr M

    2010-08-01

    The aim of this prospective longitudinal study was to compare pain experiences among Chinese adult patients treated with labial and lingual orthodontic appliances. Sixty patients, 30 with labial appliances (18 females and 12 males, mean age 20.33 years, SD +/- 4.205) and 30 with lingual appliances (22 females and 8 males, mean age 21.63 years, SD +/- 2.236), rated their overall pain experience on a 100 mm visual analogue scale (VAS) at three time points: 1 week (T(1)), 1 month (T(2)), and 3 months (T(3)) after bracket placement. In addition, on a separate 100 mm VAS, they rated their pain experience at the locations of the tongue, lips, cheeks, gums, face, and jaw at T(1), T(2), and T(3). Changes in pain VAS were conducted using Friedman analysis of variance, area under the curve (AUC) analysis and the data were compared using a t-test. There was no significant difference in global ratings of pain among those treated with labial or lingual appliances (P > 0.05). Among both groups, global ratings of pain decreased over the study period (P appliances reported higher ratings of tongue pain (P appliances reported higher ratings of lip (P appliances rate similarly the level of overall pain they experience during treatment. Ratings of overall pain experienced decreased for both treatment groups with time. However, ratings of pain differed at various sites with respect to the type of orthodontic appliance. These findings have implications in informing patients' treatment decision-making processes regarding labial and lingual appliances and in the management of discomfort associated with different treatment modalities.

  14. Dynamic computed tomography after bolus injection and infusion of perfluorooctylbromide (PFOB)

    International Nuclear Information System (INIS)

    Adam, G.; Guenther, R.W.; Goertz, H.; Schiffer, C.

    1992-01-01

    We investigated the enhancement of the liver, the spleen, and of induced abscesses and the abdominal vessels after administration of 3 g/kg bodyweight Perfluoroocytlbromide (PFOB) on an animal model. Twenty-one rabbits each received the contrast medium as bolus injection and as slow infusion over half an hour. CT was performed between 2 and 48 hours after contrast medium application. Peak enhancement of the liver, the spleen and the liver abscess membrane was found between 24 and 48 hours after PFOB administration, independently of the application mode. Peak enhancement of the abdominal aorta and the IVC was observed within two hours after bolus injection. In this rabbit model PFOB permits best delineation of the vessels after bolus injection within the first two hours, while CT imaging of the liver, the spleen and the liver abscess membrane is best between 24 and 48 hours after contrast medium application, independent of the injection velocity. (orig.) [de

  15. Propulsion Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Propulsion Lab simulates field test conditions in a controlled environment, using standardized or customized test procedures. The Propulsion Lab's 11 cells can...

  16. [Correlation between the width of lingual vein and the changes of hemodynamics of portal system in patients with primary liver cancer].

    Science.gov (United States)

    Yue, Xiao-Qiang; Gao, Jing-Dong; Zhai, Xiao-Feng; Liu, Qing; Jiang, Dong; Ling, Chang-Quan

    2006-09-01

    To explore the correlation between the width of lingual varix and changes of hemodynamics of portal system in patients with primary liver cancer so as to supply the data for the forecast of portal hypertension by observing lingual varix. The diameter of lingual vein (Dlv) was measured by vernier caliper as dependent variable, and the diameters and indexes of hemodynamics of portal vessels were measured by Doppler as independent variables, then a multipe stepwise analysis was performed. The diameters of portal vein (Dpv) and splenic vein (Dsv) entered the formula Dlv (mm) = 0.185 + 0.311 Dsv (mm) + 0.236 Dpv (mm) when the entry and removal values were alpha(in)=0.10 and alpha(out)=0.15, respectively. The width of lingual vein is closely correlated with the diameters of portal vein and splenic vein in patients with primary liver cancer.

  17. Saving radiation dose and contrast media in intravenous digital subtraction angiography by use of bolus chasing

    International Nuclear Information System (INIS)

    Rueckforth, J.; Schuermann, K.; Vorwerk, D.; Guenther, R.W.

    1998-01-01

    Purpose: This study evaluates the dose area product, the amount of contrast media and the examination quality of the bolus chasing technique compared to the single-step technique in intravenous digital subtraction angiography. Material and Methods: 15 examinations each with bolus chasing and single-step technique were compared. The dose area product and the volume of contrast media were recorded. The examination quality was scored by two examiners. Results: With bolus chasing the volume of the administered contrast media could be decreased on average by 114 ml (43%). The difference between the dose area product of bolus chasing (722 dGy/cm 2 ) and single-step technique (1910 dGy/cm 2 ) was significant. No significant difference in examination quality was found. Conclusions: The intravenous bolus chasing technique is a practicable method. Compared to the single-step technique it allows a remarkable dose reduction and a low consumption of contrast media without restriction of examination quality. (orig.) [de

  18. Performance of a glucose meter with a built-in automated bolus calculator versus manual bolus calculation in insulin-using subjects.

    Science.gov (United States)

    Sussman, Allen; Taylor, Elizabeth J; Patel, Mona; Ward, Jeanne; Alva, Shridhara; Lawrence, Andrew; Ng, Ronald

    2012-03-01

    Patients consider multiple parameters in adjusting prandial insulin doses for optimal glycemic control. Difficulties in calculations can lead to incorrect doses or induce patients to administer fixed doses, rely on empirical estimates, or skip boluses. A multicenter study was conducted with 205 diabetes subjects who were on multiple daily injections of rapid/ short-acting insulin. Using the formula provided, the subjects manually calculated two prandial insulin doses based on one high and one normal glucose test result, respectively. They also determined the two doses using the FreeStyle InsuLinx Blood Glucose Monitoring System, which has a built-in, automated bolus calculator. After dose determinations, the subjects completed opinion surveys. Of the 409 insulin doses manually calculated by the subjects, 256 (63%) were incorrect. Only 23 (6%) of the same 409 dose determinations were incorrect using the meter, and these errors were due to either confirmed or potential deviations from the study instructions by the subjects when determining dose with meter. In the survey, 83% of the subjects expressed more confidence in the meter-calculated doses than the manually calculated doses. Furthermore, 87% of the subjects preferred to use the meter than manual calculation to determine prandial insulin doses. Insulin-using patients made errors in more than half of the manually calculated insulin doses. Use of the automated bolus calculator in the FreeStyle InsuLinx meter minimized errors in dose determination. The patients also expressed confidence and preference for using the meter. This may increase adherence and help optimize the use of mealtime insulin. © 2012 Diabetes Technology Society.

  19. Recent Advances in Airframe-Propulsion Concepts with Distributed Propulsion

    OpenAIRE

    Isikveren , A.T.; Seitz , A.; Bijewitz , J.; Hornung , M.; Mirzoyan , A.; Isyanov , A.; Godard , J.L.; Stückl , S.; Van Toor , J.

    2014-01-01

    International audience; This paper discusses design and integration associated with distributed propulsion as a means of providing motive power for future aircraft concepts. The technical work reflects activities performed within a European Commission funded Framework 7 project entitled Distributed Propulsion and Ultra-high By-Pass Rotor Study at Aircraft Level, or, DisPURSAL. In this instance, the approach of distributed propulsion includes one unique solution that integrates the fuselage wi...

  20. Modified precision lingual bonding technique: A step-wise approach with torque angulation device-bracket positioning device

    Directory of Open Access Journals (Sweden)

    Rosaline Tina Paul

    2017-01-01

    Full Text Available Objectives: Contemporary preadjusted edgewise appliance is all about the precision in bracket design, prescription and positioning in addition to the orthodontist's skill and training. However, achieving it is a bigger challenge as the anatomy of the lingual surface of a tooth is uneven, dissimilar, and moreover the tooth alignment on the lingual surface is variant. Thus, the need for an accurate method of bracket positioning with predetermined torque and angulation incorporated in the brackets according to the patients' need is of key importance. Materials and Methods: A TAD-BPD machine used to enhance the accuracy of bracket positioning and bioplast accurate tray transfer technique was used. Results: A step-wise procedures in bracket positioning and fabricating an indirect bonding tray for lingual orthodontics using the torque angulation device-bracket positioning device. Conclusions: This technique facilitated unhindered bonding even in severely crowded cases and easy rebonding during mid-treatment stages.

  1. Rat lingual lipase: partial purification, hydrolytic properties, and comparison with pancreatic lipase.

    Science.gov (United States)

    Roberts, I M; Montgomery, R K; Carey, M C

    1984-10-01

    We have partially purified lingual lipase from the serous glands of rat tongue. With a combination of Triton X-100 extraction or Triton X-114 phase-separation techniques, Bio-Bead SM-2 treatment, dialysis, and gel filtration on Sephadex G-200 or Sephacryl S-300, we obtained a sparingly soluble lipid-free protein demonstrating hydrolytic activity against triglycerides and negligible phospholipase or cholesteryl esterase activities. Compared with homogenate, specific activities of the enzyme were enriched 3- to 5-fold prior to gel filtration and 10-fold after gel filtration. Analysis by sodium dodecyl sulfate-polyacrylamide gel electrophoresis and gel filtration under denaturing conditions (6 M guanidine X HCl or 0.1% sodium dodecyl sulfate) revealed one major glycoprotein band with Mr approximately 50,000. Gel filtration of the active enzyme in 0.1% Triton X-100 gave an Mr approximately 270,000-300,000, suggesting extensive self-aggregation. With both tributyrin and triolein, the pH optimum of the purified enzyme was 4.0 and activity extended from pH 2.0 to 8.0. In contrast to purified human pancreatic lipase, lingual lipase hydrolyzed triglyceride emulsions and mixed micelles stabilized with both short-chain (dihexanoyl) and long-chain (egg) lecithin and were inhibited only slightly (18-25%) by micellar concentrations of two common bile salts, taurodeoxycholate and taurocholate. Our results suggest that the hydrolysis of dietary fat by lingual lipase may extend from the pharynx through the esophagus and stomach and into the upper small intestine.

  2. Accuracy of pencil-beam redefinition algorithm dose calculations in patient-like cylindrical phantoms for bolus electron conformal therapy.

    Science.gov (United States)

    Carver, Robert L; Hogstrom, Kenneth R; Chu, Connel; Fields, Robert S; Sprunger, Conrad P

    2013-07-01

    The purpose of this study was to document the improved accuracy of the pencil beam redefinition algorithm (PBRA) compared to the pencil beam algorithm (PBA) for bolus electron conformal therapy using cylindrical patient phantoms based on patient computed tomography (CT) scans of retromolar trigone and nose cancer. PBRA and PBA electron dose calculations were compared with measured dose in retromolar trigone and nose phantoms both with and without bolus. For the bolus treatment plans, a radiation oncologist outlined a planning target volume (PTV) on the central axis slice of the CT scan for each phantom. A bolus was designed using the planning.decimal(®) (p.d) software (.decimal, Inc., Sanford, FL) to conform the 90% dose line to the distal surface of the PTV. Dose measurements were taken with thermoluminescent dosimeters placed into predrilled holes. The Pinnacle(3) (Philips Healthcare, Andover, MD) treatment planning system was used to calculate PBA dose distributions. The PBRA dose distributions were calculated with an in-house C++ program. In order to accurately account for the phantom materials a table correlating CT number to relative electron stopping and scattering powers was compiled and used for both PBA and PBRA dose calculations. Accuracy was determined by comparing differences in measured and calculated dose, as well as distance to agreement for each measurement point. The measured doses had an average precision of 0.9%. For the retromolar trigone phantom, the PBRA dose calculations had an average ± 1σ dose difference (calculated - measured) of -0.65% ± 1.62% without the bolus and -0.20% ± 1.54% with the bolus. The PBA dose calculation had an average dose difference of 0.19% ± 3.27% without the bolus and -0.05% ± 3.14% with the bolus. For the nose phantom, the PBRA dose calculations had an average dose difference of 0.50% ± 3.06% without bolus and -0.18% ± 1.22% with the bolus. The PBA dose calculations had an average dose difference of 0.65%

  3. TU-H-CAMPUS-TeP1-05: Fast Processed 3D Printing-Aided Urethane Resin (PUR) Bolus in Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, B; Chiu, T; Gu, X; Lee, H; Nedzi, L; Jiang, S [UT Southwestern Medical Center, Dallas, TX (United States)

    2016-06-15

    Purpose: 3D printed custom bolus is regularly used in radiation therapy clinic as a compensator. However, usual method of bolus printing with 100% filling is very time-consuming. The purpose of this study is to evaluate the feasibility and benefit of 3D printed bolus filled with UR. Methods: Two boluses were designed on nose (9e electrons) and ear (6× photons) for a head phantom in treatment planning system (TPS) to achieve dose coverage to the skin. The bolus structures (56–167cc) were converted to STereoLithographic (STL) model using an in-house developed algorithm and sent to a commercial fused deposition modeling (FDM) printer. Only shells were printed with polylactic acid (PLA) material. Liquid UR was then placed in a vacuum pump and slowly poured into the hollow bolus from its top opening. Liquid UR hardened in around half an hour. The phantom was rescanned with custom boluses attached and the dosimetry was compared with original design in TPS. Basic CT and dose properties were investigated. GaF films were irradiated to measure dose profile and output of several open photon and electron beams under solid water and UR slabs of same thicknesses. Results: CT number was 11.2±7.3 and 65.4±7.8, respectively for solid water(∼1.04g/cc) and UR(∼1.08g/cc). The output measurement at dmax for 6× was within 2% for the two materials. The relative dose profiles of the two materials above dmax show 94–99% Gamma analysis passing rates for both photons and electrons. Dose distributions with 3D PUR boluses maintained great coverage on the intended skin regions and resembled that with computer generated boluses. Manufacturing 3D PUR boluses was 3–4 times faster than 100% printed boluses. The efficiency significantly improves for larger boluses. Conclusion: The study suggests UR has similar dose responses as solid water. Making custom bolus with UR greatly increases clinical workflow efficiency.

  4. TU-H-CAMPUS-TeP1-05: Fast Processed 3D Printing-Aided Urethane Resin (PUR) Bolus in Radiation Therapy

    International Nuclear Information System (INIS)

    Zhao, B; Chiu, T; Gu, X; Lee, H; Nedzi, L; Jiang, S

    2016-01-01

    Purpose: 3D printed custom bolus is regularly used in radiation therapy clinic as a compensator. However, usual method of bolus printing with 100% filling is very time-consuming. The purpose of this study is to evaluate the feasibility and benefit of 3D printed bolus filled with UR. Methods: Two boluses were designed on nose (9e electrons) and ear (6× photons) for a head phantom in treatment planning system (TPS) to achieve dose coverage to the skin. The bolus structures (56–167cc) were converted to STereoLithographic (STL) model using an in-house developed algorithm and sent to a commercial fused deposition modeling (FDM) printer. Only shells were printed with polylactic acid (PLA) material. Liquid UR was then placed in a vacuum pump and slowly poured into the hollow bolus from its top opening. Liquid UR hardened in around half an hour. The phantom was rescanned with custom boluses attached and the dosimetry was compared with original design in TPS. Basic CT and dose properties were investigated. GaF films were irradiated to measure dose profile and output of several open photon and electron beams under solid water and UR slabs of same thicknesses. Results: CT number was 11.2±7.3 and 65.4±7.8, respectively for solid water(∼1.04g/cc) and UR(∼1.08g/cc). The output measurement at dmax for 6× was within 2% for the two materials. The relative dose profiles of the two materials above dmax show 94–99% Gamma analysis passing rates for both photons and electrons. Dose distributions with 3D PUR boluses maintained great coverage on the intended skin regions and resembled that with computer generated boluses. Manufacturing 3D PUR boluses was 3–4 times faster than 100% printed boluses. The efficiency significantly improves for larger boluses. Conclusion: The study suggests UR has similar dose responses as solid water. Making custom bolus with UR greatly increases clinical workflow efficiency.

  5. Automatic Bolus Tracking Versus Fixed Time-Delay Technique in Biphasic Multidetector Computed Tomography of the Abdomen

    International Nuclear Information System (INIS)

    Adibi, Atoosa; Shahbazi, Ali

    2014-01-01

    Bolus tracking can individualize time delay for the start of scans in spiral computed tomography (CT). We compared automatic bolus tracking method with fixed time-delay technique in biphasic contrast enhancement during multidetector CT of abdomen. Adult patients referred for spiral CT of the abdomen were randomized into two groups; in group 1, the arterial and portal phases of spiral scans were started 25 s and 55 s after the start of contrast material administration; in group 2, using the automatic bolus tracking software, repetitive monitoring scans were performed within the lumen of the descending aorta as the region of interest with the threshold of starting the diagnostic scans as 60 HU. The contrast enhancement of the aorta, liver, and spleen were compared between the groups. Forty-eight patients (23 males, 25 females, mean age=56.4±13.5 years) were included. The contrast enhancement of the aorta, liver, and spleen at the arterial phase was similar between the two groups (P>0.05). Regarding the portal phase, the aorta and spleen were more enhanced in the bolus-tracking group (P<0.001). The bolus tracking provided more homogeneous contrast enhancement among different patients than the fixed time-delay technique in the liver at portal phase, but not at the arterial phase. The automatic bolus-tracking method, results in higher contrast enhancement of the aorta and spleen at the portal phase, but has no effect on liver enhancement. However, bolus tracking is associated with reduced variability for liver enhancement among different patients

  6. Short Lingual Osteotomy Using a Piezosurgery Ultrasonic Bone-Cutting Device During Sagittal Split Ramus Osteotomy.

    Science.gov (United States)

    Kawase-Koga, Yoko; Mori, Yoshiyuki; Kanno, Yuki; Hoshi, Kazuto; Takato, Tsuyoshi

    2015-10-01

    Short lingual osteotomy is a useful method for the performance of sagittal split ramus osteotomy involving interference between the proximal and distal bone fragments when lateral differences exist in the setback distance. However, this procedure occasionally results in abnormal fracture and nerve injury; expert surgical skill is thus required. We herein describe a novel technique involving the use of an ultrasonic bone-cutting device (Piezosurgery; Mectron Medical Technology, Carasco, Italy) for vertical osteotomy posterior to the mandibular foramen. Successful short lingual osteotomy was performed using this technique with avoidance of abnormal fracture and neurovascular bundle damage.

  7. The Ion Propulsion System for the Solar Electric Propulsion Technology Demonstration Mission

    Science.gov (United States)

    Herman, Daniel A.; Santiago, Walter; Kamhawi, Hani; Polk, James E.; Snyder, John Steven; Hofer, Richard R.; Parker, J. Morgan

    2015-01-01

    The Asteroid Redirect Robotic Mission is a candidate Solar Electric Propulsion Technology Demonstration Mission whose main objectives are to develop and demonstrate a high-power solar electric propulsion capability for the Agency and return an asteroidal mass for rendezvous and characterization in a companion human-crewed mission. The ion propulsion system must be capable of operating over an 8-year time period and processing up to 10,000 kg of xenon propellant. This high-power solar electric propulsion capability, or an extensible derivative of it, has been identified as a critical part of an affordable, beyond-low-Earth-orbit, manned-exploration architecture. Under the NASA Space Technology Mission Directorate the critical electric propulsion and solar array technologies are being developed. The ion propulsion system being co-developed by the NASA Glenn Research Center and the Jet Propulsion Laboratory for the Asteroid Redirect Vehicle is based on the NASA-developed 12.5 kW Hall Effect Rocket with Magnetic Shielding (HERMeS0 thruster and power processing technologies. This paper presents the conceptual design for the ion propulsion system, the status of the NASA in-house thruster and power processing activity, and an update on flight hardware.

  8. Coordination and propulsion and non-propulsion phases in 100 meter breaststroke swimming.

    Science.gov (United States)

    Strzała, Marek; Krężałek, Piotr; Kucia-Czyszczoń, Katarzyna; Ostrowski, Andrzej; Stanula, Arkadiusz; Tyka, Anna K; Sagalara, Andrzej

    2014-01-01

    The main purpose of this study was to analyze the coordination, propulsion and non-propulsion phases in the 100 meter breaststroke race. Twenty-seven male swimmers (15.7 ± 1.98 years old) with the total body length (TBL) of 247.0 ± 10.60 [cm] performed an all-out 100 m breaststroke bout. The bouts were recorded with an underwater camera installed on a portable trolley. The swimming kinematic parameters, stroke rate (SR) and stroke length (SL), as well as the coordination indices based on propulsive or non-propulsive movement phases of the arms and legs were distinguished. Swimming speed (V100surface breast) was associated with SL (R = 0.41, p study were measured using partial correlations with controlled age. SL interplayed negatively with the limbs propulsive phase Overlap indicator (R = -0.46, p propulsion Glide indicator. The propulsion in-sweep (AP3) phase of arms and their non-propulsion partial air recovery (ARair) phase interplayed with V100surface breast (R = 0.51, p < 0.05 and 0.48 p < 0.05) respectively, displaying the importance of proper execution of this phase (AP3) and in reducing the resistance recovery phases in consecutive ones.

  9. Morphological, Histological and Histochemical Study of the Lingual Salivary Glands of the Little Egret, Egretta garzetta

    International Nuclear Information System (INIS)

    Almansour, Mansour I.; Jarrar, Bashir M.

    2007-01-01

    The present study aimed to study the morphological, histological and histochemical characterizations of the lingual salivary glands of the little egret, Egretta garzetta. The glands are composed of two posterior entities at the base of the tongue and one anterior entity on the dorsal surface of the free lingual part. These glands are made of mucoserous cells that elaborate sialomucins, sulfomucins and proteins, but they are devoid of glycogen and neutral mucosubstances. The findings of the present study were compared with those reported for other birds in correlation with their phylogeny and feeding habits. (author)

  10. Comparison of Insulin Detemir and Insulin Glargine for Hospitalized Patients on a Basal-Bolus Protocol

    Directory of Open Access Journals (Sweden)

    Sondra Davis

    2017-04-01

    Full Text Available BACKGROUND: The primary purpose of this study is to determine whether insulin detemir is equivalent to insulin glargine in controlling hyperglycemia for the adult hospitalized patient on a basal-bolus treatment regimen. METHODS: A retrospective study was conducted at two acute care hospitals within the same health system. Patients from both facilities who were initiated on a basal-bolus subcutaneous insulin regimen were included in the study. The basal-bolus regimen consisted of three components: basal, bolus, and corrective insulin with only the data from the first seven days analyzed. Once the basal-bolus protocol was initiated, all previous glycemic agents were discontinued. The target glycemic goal of the study was 100–180 mg/dL. RESULTS: In both groups, 50% of the patients had achieved the target glycemic control goal (100–180 mg/dL by day 2 (p = 0.3. However, on the seventh or last day of basal-bolus treatment, whichever came first, 36.36% of patients receiving insulin detemir (n = 88 achieved the blood glucose reading goal compared to 52.00% in patients receiving insulin glargine (n = 100 (p = 0.03. This corresponded to an adjusted odds ratio of 2.12 (1.08 to 4.15, p = 0.03. The adjusting variables were provider type, whether the patient was hospitalized within 30 days prior and diagnosis of stroke. The mean blood glucose readings for the insulin glargine and the insulin detemir groups while on basal-bolus therapy were 200 mg/dL and 215 mg/dL, respectively (p = 0.05. The total number of blood glucose readings less than 70 mg/dL and less than 45 mg/dL was very low and there were no differences in number of episodes with hypoglycemia between the two groups. CONCLUSION: There was not a statistical difference between the two groups at 2 days, however there was on the seventh day or the last day of basal-bolus treatment. There were nonsignificant hypoglycemia events between basal insulin groups and the results for the last or seventh day

  11. Nuclear propulsion for orbital transfer

    International Nuclear Information System (INIS)

    Beale, G.A.; Lawrence, T.J.

    1989-01-01

    The state of the art in nuclear propulsion for orbital transfer is discussed. Cryogenic propulsion, electric propulsion, solar-thermal propulsion and direct nuclear propulsion are examined in this context. New technologies with exceptional promise are addressed, emphasizing the particle test bed nuclear engine

  12. Readings on American Society. The Audio-Lingual Literary Series II.

    Science.gov (United States)

    Imamura, Shigeo; Ney, James W.

    This text contains 11 lessons based on an adaptation of the 1964 essay "Automation: Road to Lifetime Jobs" by A.H. Raskin and 14 lessons based on an adaptation of John Fischer's 1948 essay "Unwritten Rules of American Politics." The format of the book and the lessons is the same as that of the other volumes of "The Audio-Lingual Literary Series."…

  13. Tensile test and interface retention forces between wires and composites in lingual fixed retainers.

    Science.gov (United States)

    Paolone, Maria Giacinta; Kaitsas, Roberto; Obach, Patricia; Kaitsas, Vasilios; Benedicenti, Stefano; Sorrenti, Eugenio; Barberi, Fabrizio

    2015-06-01

    In daily orthodontic clinical practice retention is very important, and lingual retainers are part of this challenge. The failure of lingual retainers may be due to many factors. The aim of this study was to assess the retention forces and mechanical behavior of different types of wires matched with different kinds of composites in lingual retainers. A tensile test was performed on cylindrical composite test specimens bonded to orthodontic wires. The specimens were constructed using four different wires: a straight wire (Remanium .016×.022″ Dentaurum), two round twisted wires (Penta One .0215″ Masel, Gold Penta Twisted .0215″ Gold N'braces) and a rectangular braided wire (D-Rect .016×.022″ Ormco); and three composites: two micro-hybrids (Micro-Hybrid Enamel Plus HFO Micerium, and Micro-Hybrid SDR U Dentsply) and a micro-nano-filled composite (Micro-Nano-Filled Transbond LR 3M). The test was performed at a speed of 10mm/min on an Inström device. The wire was fixed with a clamp. The results showed that the bonding between wires and composites in lingual fixed retainers seemed to be lowest for rectangular smooth wires and increased in round twisted and rectangular twisted wires where the bonding was so strong that the maximum tension/bond strength was greater than the ultimate tensile strength of the wire. The highest values were in rectangular twisted wires. Concerning the composites, hybrid composites had the lowest interface bonding values and broke very quickly, while the nano- and micro-composites tolerated stronger forces and displayed higher bonding values. The best results were observed with the golden twisted wire and reached 21.46 MPa with the Transbond composite. With the rectangular braided wire the retention forces were so high that the Enamel Plus composite fractured when the load exceeded 154.6 N/MPa. When the same wire was combined with the Transbond LR either the wire or the composite broke when the force exceeded 240 N. The results of this

  14. Propulsion for CubeSats

    Science.gov (United States)

    Lemmer, Kristina

    2017-05-01

    At present, very few CubeSats have flown in space featuring propulsion systems. Of those that have, the literature is scattered, published in a variety of formats (conference proceedings, contractor websites, technical notes, and journal articles), and often not available for public release. This paper seeks to collect the relevant publically releasable information in one location. To date, only two missions have featured propulsion systems as part of the technology demonstration. The IMPACT mission from the Aerospace Corporation launched several electrospray thrusters from Massachusetts Institute of Technology, and BricSAT-P from the United States Naval Academy had four micro-Cathode Arc Thrusters from George Washington University. Other than these two missions, propulsion on CubeSats has been used only for attitude control and reaction wheel desaturation via cold gas propulsion systems. As the desired capability of CubeSats increases, and more complex missions are planned, propulsion is required to accomplish the science and engineering objectives. This survey includes propulsion systems that have been designed specifically for the CubeSat platform and systems that fit within CubeSat constraints but were developed for other platforms. Throughout the survey, discussion of flight heritage and results of the mission are included where publicly released information and data have been made available. Major categories of propulsion systems that are in this survey are solar sails, cold gas propulsion, electric propulsion, and chemical propulsion systems. Only systems that have been tested in a laboratory or with some flight history are included.

  15. Effect of workload setting on propulsion technique in handrim wheelchair propulsion.

    Science.gov (United States)

    van Drongelen, Stefan; Arnet, Ursina; Veeger, Dirkjan H E J; van der Woude, Lucas H V

    2013-03-01

    To investigate the influence of workload setting (speed at constant power, method to impose power) on the propulsion technique (i.e. force and timing characteristics) in handrim wheelchair propulsion. Twelve able-bodied men participated in this study. External forces were measured during handrim wheelchair propulsion on a motor driven treadmill at different velocities and constant power output (to test the forced effect of speed) and at power outputs imposed by incline vs. pulley system (to test the effect of method to impose power). Outcome measures were the force and timing variables of the propulsion technique. FEF and timing variables showed significant differences between the speed conditions when propelling at the same power output (p propulsion technique parameters despite an overall constant power output. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

  16. Development of test bolus tracking method and usefulness in coronary CT angiography

    International Nuclear Information System (INIS)

    Yamaguchi, Takayoshi; Takahashi, Daichi

    2009-01-01

    The test bolus tracking (TBT) method is a new injection method of contrast medium that we developed. The TBT method is an injection technique that continuously performs the test bolus injection and the main bolus injection, such that the best acquisition of scan timing and the improvement of examination efficiency can be expected. We compared the TBT method and the test injection method by coronary CT angiography. The results demonstrated that the contrast enhancement of the coronary arteries was high and the variation of the CT value was also small in the TBT method. When the scan timing expected by the TI method and the TBT method were compared, it was different of two seconds or more by the case with 43%. However, the variation of CT value was small for the TBT method in these cases. Therefore, the TBT method is a very useful method for coronary CT angiography (CCTA). (author)

  17. Distributed Propulsion Vehicles

    Science.gov (United States)

    Kim, Hyun Dae

    2010-01-01

    Since the introduction of large jet-powered transport aircraft, the majority of these vehicles have been designed by placing thrust-generating engines either under the wings or on the fuselage to minimize aerodynamic interactions on the vehicle operation. However, advances in computational and experimental tools along with new technologies in materials, structures, and aircraft controls, etc. are enabling a high degree of integration of the airframe and propulsion system in aircraft design. The National Aeronautics and Space Administration (NASA) has been investigating a number of revolutionary distributed propulsion vehicle concepts to increase aircraft performance. The concept of distributed propulsion is to fully integrate a propulsion system within an airframe such that the aircraft takes full synergistic benefits of coupling of airframe aerodynamics and the propulsion thrust stream by distributing thrust using many propulsors on the airframe. Some of the concepts are based on the use of distributed jet flaps, distributed small multiple engines, gas-driven multi-fans, mechanically driven multifans, cross-flow fans, and electric fans driven by turboelectric generators. This paper describes some early concepts of the distributed propulsion vehicles and the current turboelectric distributed propulsion (TeDP) vehicle concepts being studied under the NASA s Subsonic Fixed Wing (SFW) Project to drastically reduce aircraft-related fuel burn, emissions, and noise by the year 2030 to 2035.

  18. Evaluation of various boluses in dose distribution for electron therapy of the chest wall with an inward defect

    Science.gov (United States)

    Mahdavi, Hoda; Jabbari, Keyvan; Roayaei, Mahnaz

    2016-01-01

    Delivering radiotherapy to the postmastectomy chest wall can be achieved using matched electron fields. Surgical defects of the chest wall change the dose distribution of electrons. In this study, the improvement of dose homogeneity using simple, nonconformal techniques of thermoplastic bolus application on a defect is evaluated. The proposed phantom design improves the capability of film dosimetry for obtaining dose profiles of a patient's anatomical condition. A modeled electron field of a patient with a postmastectomy inward surgical defect was planned. High energy electrons were delivered to the phantom in various settings, including no bolus, a bolus that filled the inward defect (PB0), a uniform thickness bolus of 5 mm (PB1), and two 5 mm boluses (PB2). A reduction of mean doses at the base of the defect was observed by any bolus application. PB0 increased the dose at central parts of the defect, reduced hot areas at the base of steep edges, and reduced dose to the lung and heart. Thermoplastic boluses that compensate a defect (PB0) increased the homogeneity of dose in a fixed depth from the surface; adversely, PB2 increased the dose heterogeneity. This study shows that it is practical to investigate dose homogeneity profiles inside a target volume for various techniques of electron therapy. PMID:27051169

  19. Impacto da remoção de biofilme lingual em pacientes sob ventilação mecânica

    Directory of Open Access Journals (Sweden)

    Paulo Sérgio da Silva Santos

    2013-03-01

    Full Text Available OBJETIVO: Avaliar a eficiência de limpador de língua para remoção do biofilme lingual em pacientes sob ventilação mecânica. MÉTODOS: Foram coletadas amostras de biofilme lingual e de secreção traqueal de 50 pacientes intubados ou traqueostomizados sob ventilação assistida em grupo de estudo (GE - uso de limpador lingual e grupo controle (GC - sem higienização da língua. Foi realizada cultura de secreção oral e traqueal do GE (inicialmente e após 5 dias e do GC (em momento único para avaliar as modificações na flora bacteriana. RESULTADOS: Os pacientes do GE tinham mediana de idade de 77 (45-99 anos, e os do GC de 79 (21-94 anos. O período de internação dos pacientes do GE oscilou entre 17 e 1.370 dias, com mediana de 425 dias, e do GC, entre 4 e 240 dias, com mediana de 120 dias. Na comparação do índice de placa bacteriana bucal entre os grupos de estudo e controle, não foram encontradas diferenças significantes. Não houve correlação entre esse índice e o tempo de internação. A mesma flora bacteriana foi encontrada na placa bacteriana bucal antes e após 5 dias de uso do raspador lingual no GE, somente em 9 dos 27 casos em relação ao encontrado no GC (p=0,683. Em 7 dos 27 pacientes do GE houve positividade de culturas bacterianas com as mesmas cepas tanto para biofilme lingual quanto para secreção traqueal (p=0,003 em relação ao GC. A similaridade na resistência e na sensibilidade das cepas dos micro-organismos encontrados, com o objetivo de associar a flora do biofilme lingual com a da secreção traqueal, mostrou significância em 6/23 casos somente no GC (p=0,006. CONCLUSÃO: O uso do limpador de língua é um mecanismo efetivo na redução do biofilme lingual em pacientes sob ventilação mecânica, além de facilitar a ação dos cuidadores para ações de higiene bucal.

  20. Development of a universal dual-bolus injection scheme for the quantitative assessment of myocardial perfusion cardiovascular magnetic resonance

    Directory of Open Access Journals (Sweden)

    Alfakih Khaled

    2011-05-01

    Full Text Available Abstract Background The dual-bolus protocol enables accurate quantification of myocardial blood flow (MBF by first-pass perfusion cardiovascular magnetic resonance (CMR. However, despite the advantages and increasing demand for the dual-bolus method for accurate quantification of MBF, thus far, it has not been widely used in the field of quantitative perfusion CMR. The main reasons for this are that the setup for the dual-bolus method is complex and requires a state-of-the-art injector and there is also a lack of post processing software. As a solution to one of these problems, we have devised a universal dual-bolus injection scheme for use in a clinical setting. The purpose of this study is to show the setup and feasibility of the universal dual-bolus injection scheme. Methods The universal dual-bolus injection scheme was tested using multiple combinations of different contrast agents, contrast agent dose, power injectors, perfusion sequences, and CMR scanners. This included 3 different contrast agents (Gd-DO3A-butrol, Gd-DTPA and Gd-DOTA, 4 different doses (0.025 mmol/kg, 0.05 mmol/kg, 0.075 mmol/kg and 0.1 mmol/kg, 2 different types of injectors (with and without "pause" function, 5 different sequences (turbo field echo (TFE, balanced TFE, k-space and time (k-t accelerated TFE, k-t accelerated balanced TFE, turbo fast low-angle shot and 3 different CMR scanners from 2 different manufacturers. The relation between the time width of dilute contrast agent bolus curve and cardiac output was obtained to determine the optimal predefined pause duration between dilute and neat contrast agent injection. Results 161 dual-bolus perfusion scans were performed. Three non-injector-related technical errors were observed (1.9%. No injector-related errors were observed. The dual-bolus scheme worked well in all the combinations of parameters if the optimal predefined pause was used. Linear regression analysis showed that the optimal duration for the predefined

  1. Centralized versus distributed propulsion

    Science.gov (United States)

    Clark, J. P.

    1982-01-01

    The functions and requirements of auxiliary propulsion systems are reviewed. None of the three major tasks (attitude control, stationkeeping, and shape control) can be performed by a collection of thrusters at a single central location. If a centralized system is defined as a collection of separated clusters, made up of the minimum number of propulsion units, then such a system can provide attitude control and stationkeeping for most vehicles. A distributed propulsion system is characterized by more numerous propulsion units in a regularly distributed arrangement. Various proposed large space systems are reviewed and it is concluded that centralized auxiliary propulsion is best suited to vehicles with a relatively rigid core. These vehicles may carry a number of flexible or movable appendages. A second group, consisting of one or more large flexible flat plates, may need distributed propulsion for shape control. There is a third group, consisting of vehicles built up from multiple shuttle launches, which may be forced into a distributed system because of the need to add additional propulsion units as the vehicles grow. The effects of distributed propulsion on a beam-like structure were examined. The deflection of the structure under both translational and rotational thrusts is shown as a function of the number of equally spaced thrusters. When two thrusters only are used it is shown that location is an important parameter. The possibility of using distributed propulsion to achieve minimum overall system weight is also examined. Finally, an examination of the active damping by distributed propulsion is described.

  2. Ultrastructural study on the embryonic development of the orthokeratinized epithelium and its cornified layer (lingual nail) on the ventral surface of the lingual apex in the domestic duck (Anas platyrhynchos f. domestica).

    Science.gov (United States)

    Skieresz-Szewczyk, Kinga; Jackowiak, Hanna; Ratajczak, Marlena

    2018-02-01

    The lingual nail as the cornified layer of the orthokeratinized epithelium in birds is responsible for the collection of solid food by pecking. The aim of the present study is to determine the manner of orthokeratinized epithelium development and assess the degree of readiness of the epithelium to fulfill its mechanical function at hatching. Three developmental phases are distinguished, i.e. embryonic, transformation and pre-hatching stage. In the embryonic stage lasting until day 13 of incubation the epithelium is composed of several layers of undifferentiated cells. During the transformation stage, from day 14 to 20 of incubation, the epithelium becomes differentiated to form three layers. A characteristic feature is the formation of osmophilic granules in the superficial layer, referred to as periderm granules. Until the pre-hatching stage the fibrous cytoskeleton of epithelial cells and an impermeable epithelial barrier are gradually developed. In the pre-hatching stage, a cornified lingual nail is formed, while the periderm is exfoliated. At hatching the orthokeratinized epithelium and lingual nail are fully developed and ready to perform feeding activities. The presence of periderm, similarly as in the epidermis, indicates the ectodermal derivation of the oral cavity epithelium. Moreover, occurrence of osmophilic granules may be considered as evidence for the phylogenetic affinity of birds and reptiles. Copyright © 2018 Elsevier GmbH. All rights reserved.

  3. Results of surgical excision and evaluation of factors associated with survival time in dogs with lingual neoplasia: 97 cases (1995-2008).

    Science.gov (United States)

    Culp, William T N; Ehrhart, Nicole; Withrow, Stephen J; Rebhun, Robert B; Boston, Sarah; Buracco, Paolo; Reiter, Alexander M; Schallberger, Sandra P; Aldridge, Charles F; Kent, Michael S; Mayhew, Philipp D; Brown, Dorothy C

    2013-05-15

    To describe the clinical characteristics, treatments, outcomes, and factors associated with survival time in a cohort of dogs with lingual neoplasia that underwent surgical excision. Retrospective case series. Animals-97 client-owned dogs. Medical records of dogs with a lingual tumor examined between 1995 and 2008 were reviewed. Records were included if a lingual tumor was confirmed by histologic examination and surgical excision of the mass was attempted. Data were recorded and analyzed to identify prognostic factors. Clinical signs were mostly related to the oral cavity. For 93 dogs, marginal excision, subtotal glossectomy, and near-total glossectomy were performed in 35 (38%), 55 (59%), and 3 (3%), respectively. Surgery-related complications were rare, but 27 (28%) dogs had tumor recurrence. The most common histopathologic diagnoses for the 97 dogs were squamous cell carcinoma (31 [32%]) and malignant melanoma (29 [30%]). Eighteen (19%) dogs developed metastatic disease, and the overall median survival time was 483 days. Median survival time was 216 days for dogs with squamous cell carcinoma and 241 days for dogs with malignant melanoma. Dogs with lingual tumors ≥ 2 cm in diameter at diagnosis had a significantly shorter survival time than did dogs with tumors melanoma predominate. A thorough physical examination to identify lingual tumors at an early stage and surgical treatment after tumor identification are recommended because tumor size significantly affected survival time.

  4. A Cross-Lingual Similarity Measure for Detecting Biomedical Term Translations

    Science.gov (United States)

    Bollegala, Danushka; Kontonatsios, Georgios; Ananiadou, Sophia

    2015-01-01

    Bilingual dictionaries for technical terms such as biomedical terms are an important resource for machine translation systems as well as for humans who would like to understand a concept described in a foreign language. Often a biomedical term is first proposed in English and later it is manually translated to other languages. Despite the fact that there are large monolingual lexicons of biomedical terms, only a fraction of those term lexicons are translated to other languages. Manually compiling large-scale bilingual dictionaries for technical domains is a challenging task because it is difficult to find a sufficiently large number of bilingual experts. We propose a cross-lingual similarity measure for detecting most similar translation candidates for a biomedical term specified in one language (source) from another language (target). Specifically, a biomedical term in a language is represented using two types of features: (a) intrinsic features that consist of character n-grams extracted from the term under consideration, and (b) extrinsic features that consist of unigrams and bigrams extracted from the contextual windows surrounding the term under consideration. We propose a cross-lingual similarity measure using each of those feature types. First, to reduce the dimensionality of the feature space in each language, we propose prototype vector projection (PVP)—a non-negative lower-dimensional vector projection method. Second, we propose a method to learn a mapping between the feature spaces in the source and target language using partial least squares regression (PLSR). The proposed method requires only a small number of training instances to learn a cross-lingual similarity measure. The proposed PVP method outperforms popular dimensionality reduction methods such as the singular value decomposition (SVD) and non-negative matrix factorization (NMF) in a nearest neighbor prediction task. Moreover, our experimental results covering several language pairs such as

  5. A cross-lingual similarity measure for detecting biomedical term translations.

    Directory of Open Access Journals (Sweden)

    Danushka Bollegala

    Full Text Available Bilingual dictionaries for technical terms such as biomedical terms are an important resource for machine translation systems as well as for humans who would like to understand a concept described in a foreign language. Often a biomedical term is first proposed in English and later it is manually translated to other languages. Despite the fact that there are large monolingual lexicons of biomedical terms, only a fraction of those term lexicons are translated to other languages. Manually compiling large-scale bilingual dictionaries for technical domains is a challenging task because it is difficult to find a sufficiently large number of bilingual experts. We propose a cross-lingual similarity measure for detecting most similar translation candidates for a biomedical term specified in one language (source from another language (target. Specifically, a biomedical term in a language is represented using two types of features: (a intrinsic features that consist of character n-grams extracted from the term under consideration, and (b extrinsic features that consist of unigrams and bigrams extracted from the contextual windows surrounding the term under consideration. We propose a cross-lingual similarity measure using each of those feature types. First, to reduce the dimensionality of the feature space in each language, we propose prototype vector projection (PVP--a non-negative lower-dimensional vector projection method. Second, we propose a method to learn a mapping between the feature spaces in the source and target language using partial least squares regression (PLSR. The proposed method requires only a small number of training instances to learn a cross-lingual similarity measure. The proposed PVP method outperforms popular dimensionality reduction methods such as the singular value decomposition (SVD and non-negative matrix factorization (NMF in a nearest neighbor prediction task. Moreover, our experimental results covering several language

  6. Efficacy study of Styplon Vet Bolus as supportive therapy in management of hemorrhagic conditions of ruminants

    Directory of Open Access Journals (Sweden)

    B R Ravikumar

    Full Text Available On-field trial was conducted in dairy animals to evaluate efficacy of Styplon Vet Bolus (M/s Himalaya Drug Company, Banglore, India as supportive therapy in management of hemorrhagic conditions (Hematuria, hemoagalectia, bleeding wounds, uterine bleeding and epistaxis of ruminants. Styplon Vet 1-2 boli twice daily was administered to cows and buffaloes, and ½ bolus twice daily for sheep till they recover clinically. The results indicated that Styplon Vet Bolus is a safe and effective styptic in ruminants. [Vet World 2009; 2(12.000: 470-471

  7. Radioelectric asymmetric brain stimulation and lingual apex repositioning in patients with atypical deglutition

    Directory of Open Access Journals (Sweden)

    Castagna A

    2011-06-01

    Full Text Available Alessandro Castagna1, Salvatore Rinaldi1,2, Vania Fontani1, Piero Mannu11Rinaldi-Fontani Institute, 2School of Occupational Medicine, University of Florence, Florence, ItalyBackground: Atypical deglutition is exacerbated by stress and anxiety. Several therapeutic approaches have been employed to treat stress and anxiety disorders, ranging from typical psychopharmacological strategies to novel physical protocols, such as transcranial magnetic stimulation and radioelectric asymmetric conveyor (REAC stimulation. The purpose of the present study was to test the efficacy of REAC brain stimulation in atypical deglutition.Methods: The position of the lingual apex (Payne method, pattern of free deglutition, and subjective and objective impression of deglutition were evaluated in 128 outpatients suffering from atypical deglutition. Deglutition testing consisted of an operator holding down the lower lip, hence counteracting the strength exerted by the orbicularis muscle. All subjects were treated using two REAC brain stimulation protocols. Patients were assessed before treatment, immediately after treatment, and three months following the last cycle of REAC therapy.Results: REAC stimulation led to an improvement in positioning of the lingual apex and a significant decrease of muscle involvement in all patients immediately after REAC treatment, and the improvement was maintained at three-month follow-up.Conclusion: In the present study, the REAC therapeutic protocols led to normalization in lingual apex positioning and significant improvement in swallowing in all participants suffering from atypical deglutition.Keywords: atypical deglutition, stress, anxiety, radioelectric asymmetric brain stimulation

  8. 21 CFR 520.1802b - Piperazine-carbon disulfide complex boluses.

    Science.gov (United States)

    2010-04-01

    ...) per 500 pounds body weight; removal of large strongyles, pinworms, and bots, 1 bolus per 250 pounds...), large strongyles (Strongylus spp.) bots (Gastrophilus spp.), small strongyles, and pinworms (Oxyuris...

  9. Dual-phase helical CT using bolus triggering technique: optimization of transition time

    International Nuclear Information System (INIS)

    Choi, Young Ho; Kim, Tae Kyoung; Park, Byung Kwan; Koh, Young Hwan; Han, Joon Koo; Choi, Byung Ihn

    1999-01-01

    To optimize the transition time between the triggering point in monitoring scanning and the initiation of diagnostic hepatic arterial phase (HAP) scanning in hepatic spiral CT, using a bolus triggering technique. One hundred consecutive patients with focal hepatic lesion were included in this study. Patients were randomized into two groups. Transition times of 7 and 11 seconds were used in group 1 and 2, respectively. In all patients, bolus triggered HAP spiral CT was obtained using a semi-automatic bolus tracking program after the injection of 120mL of non-ionic contrast media at a rate of 3mL/sec. When aortic enhancement reached 90 HU, diagnostic HAP scanning began after a given transition time. From images of group 1 and group 2, the degree of parenchymal enhancement of the liver and tumor-to-liver attenuation difference were measured. Also, for qualitative analysis, conspicuity of the hepatic artery and hypervascular tumor was scored and analyzed. Hepatic parenchymal enhancement on HAP was 12.07 + /-6.44 HU in group 1 and 16.03 + /-5.80 HU in group 2 (p .05). In the evaluation of conspicuity of hepatic artery, there was no statistically significant difference between the two groups (p > .05). The conspicuity of hypervascular tumors in group 2 was higher than in group 1 (p < .05). HAP spiral CT using a bolus triggering technique with a transition time of 11 seconds provides better HAP images than when the transition time is 7 seconds

  10. Nuclear electric propulsion: An integral part of NASA's nuclear propulsion project

    International Nuclear Information System (INIS)

    Stone, J.R.

    1992-01-01

    NASA has initiated a technology program to establish the readiness of nuclear propulsion technology for the Space Exploration Initiative (SEI). This program was initiated with a very modest effort identified with nuclear thermal propulsion (NTP); however, nuclear electric propulsion (NEP) is also an integral part of this program and builds upon NASA's Base Research and Technology Program in power and electric propulsion as well as the SP-100 space nuclear power program. Although the Synthesis Group On America's SEI has identified NEP only as an option for cargo missions, recent studies conducted by NASA-Lewis show that NEP offers the potential for early manned Mars missions as well. Lower power NEP is also of current interest for outer planetary robotic missions. Current plans are reviewed for the overall nuclear propulsion project, with emphasis on NEP and those elements of NTP program which have synergism with NEP

  11. Functional aspects of distal oesophageal spasm: the role of onset velocity and contraction amplitude on bolus transit

    Science.gov (United States)

    Pohl, Daniel; Ciolino, Jody; Roberts, Jason; Savarino, Edoardo; Freeman, Janice; Nietert, Paul J; Tutuian, Radu; Castell, Donald

    2012-01-01

    Background Distal oesophageal spasm (DES) is a rare and under-investigated motility abnormality. Recent studies indicate effective bolus transit in varying percentages of DES patients. Aim Explore functional aspects including contraction onset velocity and contraction amplitude cut-off values for simultaneous contractions to predict complete bolus transit Methods We re-examined data from 107 impedance-manometry recordings with a diagnosis of DES. Receiver operating characteristic (ROC) analysis was conducted, regarding effects of onset velocity on bolus transit taking into account distal oesophageal amplitude (DEA) and correcting for intra-individual repeated measures. Results Mean area under the ROC curve for saline and viscous swallows were 0.84±0.05 and 0.84±0.04, respectively. Velocity criteria of >30cm/s when DEA>100mmHg and 8cm/s when DEADEA>100mmHg and >7cm/s when DEAsensitivity of 75% and specificity of 80% to identify complete bolus transit. Using these criteria, final diagnosis changed in 44.9% of patients. Abnormal bolus transit was observed in 50.9% of newly diagnosed DES patients versus 7.5% of patients classified as normal. DES patients with DEA>100mmHg suffered twice as often from chest pain than those with DEA<100mmHg. Conclusion The proposed velocity cut-offs for diagnosing distal oesophageal spasm improve the ability to identify patients with spasm and abnormal bolus transit. PMID:22475443

  12. Establishment of a Novel Lingual Organoid Culture System: Generation of Organoids Having Mature Keratinized Epithelium from Adult Epithelial Stem Cells

    Science.gov (United States)

    Hisha, Hiroko; Tanaka, Toshihiro; Kanno, Shohei; Tokuyama, Yoko; Komai, Yoshihiro; Ohe, Shuichi; Yanai, Hirotsugu; Omachi, Taichi; Ueno, Hiroo

    2013-11-01

    Despite the strong need for the establishment of a lingual epithelial cell culture system, a simple and convenient culture method has not yet been established. Here, we report the establishment of a novel lingual epithelium organoid culture system using a three-dimensional matrix and growth factors. Histological analyses showed that the generated organoids had both a stratified squamous epithelial cell layer and a stratum corneum. Very recently, we showed via a multicolor lineage tracing method that Bmi1-positive stem cells exist at the base of the epithelial basal layer in the interpapillary pit. Using our new culture system, we found that organoids could be generated by single Bmi1-positive stem cells and that in the established organoids, multiple Bmi1-positive stem cells were generated at the outermost layer. Moreover, we observed that organoids harvested at an early point in culture could be engrafted and maturate in the tongue of recipient mice and that the organoids generated from carcinogen-treated mice had an abnormal morphology. Thus, this culture system presents valuable settings for studying not only the regulatory mechanisms of lingual epithelium but also lingual regeneration and carcinogenesis.

  13. Ribbon-wise customized lingual appliance and orthodontic anchor screw for the treatment of skeletal high-angle maxillary protrusion without bowing effect.

    Science.gov (United States)

    Inami, Toru; Ito, Goshi; Miyazawa, Ken; Tabuchi, Masako; Goto, Shigemi

    2018-05-02

    This case report demonstrates the treatment of a skeletal Class II high-angle adult patient with bimaxillary protrusion, angle Class I occlusion, and crowded anterior teeth. A ribbon-wise arch wire and a customized lingual appliance with anterior vertical slots were used to achieve proper torque control of the maxillary anterior teeth. An orthodontic anchor screw and a palatal bar were used for vertical control to avoid increasing the Frankfort-mandibular plane angle (FMA) by maxillary molar extrusion. Through the combined use of the ribbon-wise customized lingual appliance, palatal bar, and orthodontic anchor screw, vertical control and an excellent treatment result were achieved without the vertical and horizontal bowing effects peculiar to conventional lingual treatment.

  14. Manual wheelchair propulsion patterns on natural surfaces during start-up propulsion.

    Science.gov (United States)

    Koontz, Alicia M; Roche, Bailey M; Collinger, Jennifer L; Cooper, Rory A; Boninger, Michael L

    2009-11-01

    To classify propulsion patterns over surfaces encountered in the natural environment during start-up and compare selected biomechanical variables between pattern types. Case series. National Veterans Wheelchair Games, Minneapolis, MN, 2005. Manual wheelchair users (N=29). Subjects pushed their wheelchairs from a resting position over high-pile carpet, over linoleum, and up a ramp with a 5 degrees incline while propulsion kinematics and kinetics were recorded with a motion capture system and an instrumented wheel. Three raters classified the first 3 strokes as 1 of 4 types on each surface: arc, semicircular (SC), single looping over propulsion (SL), and double looping over propulsion (DL). The Fisher exact test was used to assess pattern changes between strokes and surface type. A multiple analysis of variance test was used to compare peak and average resultant force and moment about the hub, average wheel velocity, stroke frequency, contact angle, and distance traveled between stroke patterns. SL was the most common pattern used during start-up propulsion (44.9%), followed by arc (35.9%), DL (14.1%), and SC (5.1%). Subjects who dropped their hands below the rim during recovery achieved faster velocities and covered greater distances (.016propulsion patterns is a difficult task that should use multiple raters. In addition, propulsion patterns change during start-up, with an arc pattern most prevalent initially. The biomechanical findings in this study agree with current clinical guidelines that recommend training users to drop the hand below the pushrim during recovery.

  15. Total intravenous anaesthesia by boluses or by continuous rate infusion of propofol in mute swans (Cygnus olor).

    Science.gov (United States)

    Müller, Kerstin; Holzapfel, Judith; Brunnberg, Leo

    2011-07-01

    To investigate intravenous (IV) propofol given by intermittent boluses or by continuous rate infusion (CRI) for anaesthesia in swans. Prospective randomized clinical study. Twenty mute swans (Cygnus olor) (eight immature and 12 adults) of unknown sex undergoing painless diagnostic or therapeutic procedures. Induction of anaesthesia was with 8 mg kg(-1) propofol IV. To maintain anaesthesia, ten birds (group BOLI) received propofol as boluses, whilst 10 (group CRI) received propofol as a CRI. Some physiological parameters were measured. Anaesthetic duration was 35 minutes. Groups were compared using Mann-Whitney U-test. Results are median (range). Anaesthetic induction was smooth and tracheal intubation was achieved easily in all birds. Bolus dose in group BOLI was 2.9 (1.3-4.3) mg kg(-1); interval between and number of boluses required were 4 (1-8) minutes and 6 (4-11) boluses respectively. Total dose of propofol was 19 (12.3-37.1) mg kg(-1). Awakening between boluses was very abrupt. In group CRI, propofol infusion rate was 0.85 (0.8-0.9) mg kg(-1) minute(-1), and anaesthesia was stable. Body temperature, heart and respiratory rates, oxygen saturation (by pulse oximeter) and reflexes did not differ between groups. Oxygen saturations (from pulse oximeter readings) were low in some birds. Following anaesthesia, all birds recovered within 40 minutes. In 55% of all, transient signs of central nervous system excitement occurred during recovery. 8 mg kg(-1) propofol appears an adequate induction dose for mute swans. For maintenance, a CRI of 0.85 mg kg(-1) minute(-1) produced stable anaesthesia suitable for painless clinical procedures. In contrast bolus administration, was unsatisfactory as birds awoke very suddenly, and the short intervals between bolus requirements hampered clinical procedures. Administration of additional oxygen throughout anaesthesia might reduce the incidence of low arterial haemoglobin saturation. © 2011 The Authors. Veterinary Anaesthesia and

  16. Esophagogastric junction outflow obstruction is often associated with coexistent abnormal esophageal body motility and abnormal bolus transit.

    Science.gov (United States)

    Zheng, E; Gideon, R M; Sloan, J; Katz, P O

    2017-10-01

    Currently, the diagnosis of esophageal motility disorders is in part based upon a hierarchical algorithm in which abnormalities of the esophagogastric junction (EGJ) is prioritized. An important metric in evaluating the EGJ is the integrated relaxation pressure (IRP). Patients who do not have achalasia but are found to have an elevated IRP are diagnosed with EGJ outflow obstruction. It has been our observation that a subset of these patients also has a second named motility disorder and may also have abnormal bolus transit. The aim of this study is to determine the frequency of abnormal body motility and or abnormal bolus movement in patients with EGJ outflow obstruction. Further, in an effort to evaluate the potential clinical value in measuring bolus transit as a complement to esophageal manometry, specifically in patients with EGJ outflow obstruction, we analyzed the presenting symptoms of these patients. A total of 807 patients with a mean age of 53 years completed esophageal function testing with impedance monitoring and high-resolution manometry between January 2012 and October 2016. There were 74 patients with achalasia who were excluded from the study. Of the remaining 733 patients, 138 (19%) had an elevated IRP and were given a diagnosis of EGJ outflow obstruction. Among these patients, 56 (40%) were diagnosed with an abnormal motility pattern to liquids (ineffective esophageal motility = 28, distal esophageal spasm = 19, Jackhammer = 6), of which 44 (76%) had abnormal bolus transit to liquids, viscous, or both. In contrast, there were 82 patients with EGJ outflow obstruction and normal esophageal motility, of which 33 (40%) had abnormal bolus transit. Patients with preserved esophageal motility and EGJ outflow obstruction were then evaluated. Of the 733 patients, 299 (40%) had intact esophageal motility. Of the 299 patients with normal esophageal motility, 56 patients had an elevated IRP, of which 16 (28%) had abnormal bolus transit. There were 243 (33

  17. Review article : intra-oesophageal impedance monitoring for the assessment of bolus transit and gastro-oesophageal reflux

    NARCIS (Netherlands)

    Conchillo, J. M.; Smout, A. J.

    2009-01-01

    Background Intra-oesophageal impedance monitoring can be used to assess the clearance of a swallowed bolus (oesophageal transit) and to detect gastro-oesophageal reflux independent of its acidity. Aim To discuss the clinical application of the impedance technique for the assessment of bolus transit

  18. Transversus Abdominis Plane Catheter Bolus Analgesia after Major Abdominal Surgery

    Directory of Open Access Journals (Sweden)

    Nils Bjerregaard

    2012-01-01

    Full Text Available Purpose. Transversus abdominis plane (TAP blocks have been shown to reduce pain and opioid requirements after abdominal surgery. The aim of the present case series was to demonstrate the use of TAP catheter injections of bupivacaine after major abdominal surgery. Methods. Fifteen patients scheduled for open colonic resection surgery were included. After induction of anesthesia, bilateral TAP catheters were placed, and all patients received a bolus dose of 20 mL bupivacaine 2.5 mg/mL with epinephrine 5 μg/mL through each catheter. Additional bolus doses were injected bilaterally 12, 24, and 36 hrs after the first injections. Supplemental pain treatment consisted of paracetamol, ibuprofen, and gabapentin. Intravenous morphine was used as rescue analgesic. Postoperative pain was rated on a numeric rating scale (NRS, 0–10 at regular predefined intervals after surgery, and consumption of intravenous morphine was recorded. Results. The TAP catheters were placed without any technical difficulties. NRS scores were ≤3 at rest and ≤5 during cough at 4, 8, 12, 18, 24, and 36 hrs after surgery. Cumulative consumption of intravenous morphine was 28 (23–48 mg (median, IQR within the first 48 postoperative hours. Conclusion. TAP catheter bolus injections can be used to prolong analgesia after major abdominal surgery.

  19. Darkening of third molar roots on panoramic radiographs: is it really predominantly thinning of the lingual cortex?

    Science.gov (United States)

    Szalma, J; Vajta, L; Lempel, E; Jeges, S; Olasz, L

    2013-04-01

    This study investigated the exact intra-alveolar aetiology of a panoramic high-risk sign, darkening of the third molar roots. 83 mandibular third molar surgical removals demonstrating dark bands on the third molar roots in preoperative radiographs were included in this prospective study. Exposure of the inferior alveolar nerve (IAN), the root morphology of the third molar (e.g. groove or hook) and the integrity of the mandibular canal or lingual cortical wall were observed. Differences between single (increased radiolucency alone) and multiple darkening cases (increased radiolucency with accompanying 'high risk' signs) and between IAN exposure and groove formation were analysed. In 38 cases (45.8%), the IAN was visible during the operation. Groove was present in 37.4% of cases. 26.5% of the cases showed lingual cortical thinning, while specious root conformation explained the formation of darkening on the radiographic images of an additional 9.6% of the cases. IAN exposure (Pformation (Pformation of the root than lingual cortical thinning. Copyright © 2012 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  20. Survival of flexible, braided, bonded stainless steel lingual retainers : a historic cohort study

    NARCIS (Netherlands)

    Foek, D. J. Lie Sam; Ozcan, M.; Verkerke, G. J.; Sandham, John; Dijkstra, P. U.

    The objectives of this study were to retrospectively evaluate the clinical survival rate of flexible, braided, rectangular bonded stainless steel lingual retainers, and to investigate the influence of gender, age of the patient, and operator experience on survival after orthodontic treatment at the

  1. The SMPR for the naval propulsion; Les RPMP pour la propulsion navale

    Energy Technology Data Exchange (ETDEWEB)

    Gauducheau, B. [Technicatome, Centre d' Etudes Nucleaires de Saclay, 91 - Gif sur Yvette (France)

    2002-07-01

    The first controlled application of the fissile energy was the american nuclear reactor for the ship propulsion. Since the sixties, the France begun researches to secure the independence of its nuclear propulsion program. The historical aspects, the french program management and the perspectives of the ship nuclear propulsion, are discussed in this paper. (A.L.B.)

  2. Dextrose boluses versus burette dextrose infusions in prevention of ...

    African Journals Online (AJOL)

    The incidence of hypoglycemia in the bolus arm was 59% (40/68) compared to 11% (8/72) in the ... and safety monitoring board (DSMB) was set up to oversee to ..... On the other hand, Namukwaya et al in a prospective study at Mulago ...

  3. Impacts of palatal coverage on bolus formation during mastication and swallowing and subsequent adaptive changes.

    Science.gov (United States)

    Sato, T; Furuya, J; Tamada, Y; Kondo, H

    2013-10-01

    Palatal coverage is often required for elderly edentulous patients with complete dentures. The purpose of this study was to clarify impacts of palatal coverage on bolus formation and subsequent adaptive changes. Subjects were 18 healthy young dentulous adults who wore 1·5-mm-thick palatal plates. Subjects were asked to feed 12 g of bicoloured rice as usual, and the bolus formation by mastication and swallowing in the pharynx was observed using a nasal videoendoscopy. The bolus formation index (BFI), number of mastication strokes until swallowing, visual analogue scale about swallowing easiness and masticatory performance using colour-changeable gum were measured under three conditions: before placement of the palatal plate (day 0), immediately after placement (day 1) and after 7 days of wearing the plate (day 7). BFI and visual analogue scale on day 1 were significantly lower than those on day 0, but those on day 7 significantly recovered to the level of day 0. The number of mastication strokes did not change from day 0 to day 1, however, that on day 7 was significantly higher. Masticatory performance on days 1 and 7 was significantly lower than that on day 0. Although palatal coverage inhibits bolus formation during feeding, subjects increased the number of mastication strokes until swallowing threshold as they adapted to palatal coverage over time. This adaptive change was due to compensate for the lowered masticatory performance to achieve bolus formation for comfortable swallowing. © 2013 John Wiley & Sons Ltd.

  4. Lingual-Alveolar Contact Pressure during Speech in Amyotrophic Lateral Sclerosis: Preliminary Findings

    Science.gov (United States)

    Searl, Jeff; Knollhoff, Stephanie; Barohn, Richard J.

    2017-01-01

    Purpose: This preliminary study on lingual-alveolar contact pressures (LACP) in people with amyotrophic lateral sclerosis (ALS) had several aims: (a) to evaluate whether the protocol induced fatigue, (b) to compare LACP during speech (LACP-Sp) and during maximum isometric pressing (LACP-Max) in people with ALS (PALS) versus healthy controls, (c)…

  5. The USAF Electric Propulsion Program

    National Research Council Canada - National Science Library

    Spores, Ronald

    1999-01-01

    ...: Propulsion Directorate and Air Force Office of Scientific Research (AFOSR). The Propulsion Directorate conducts electric propulsion efforts in basic research, engineering development, and space experiments...

  6. Advanced Propulsion Study

    National Research Council Canada - National Science Library

    Davis, Eric

    2004-01-01

    ... that show promise of leading to a major advance in Earth-to-orbit (ETO) propulsion. The study also reviewed and evaluated a select number of credible far-term breakthrough propulsion physics concepts pertaining...

  7. NASA's Propulsion Research Laboratory

    Science.gov (United States)

    2004-01-01

    The grand opening of NASA's new, world-class laboratory for research into future space transportation technologies located at the Marshall Space Flight Center (MSFC) in Huntsville, Alabama, took place in July 2004. The state-of-the-art Propulsion Research Laboratory (PRL) serves as a leading national resource for advanced space propulsion research. Its purpose is to conduct research that will lead to the creation and development of innovative propulsion technologies for space exploration. The facility is the epicenter of the effort to move the U.S. space program beyond the confines of conventional chemical propulsion into an era of greatly improved access to space and rapid transit throughout the solar system. The laboratory is designed to accommodate researchers from across the United States, including scientists and engineers from NASA, the Department of Defense, the Department of Energy, universities, and industry. The facility, with 66,000 square feet of useable laboratory space, features a high degree of experimental capability. Its flexibility allows it to address a broad range of propulsion technologies and concepts, such as plasma, electromagnetic, thermodynamic, and propellant propulsion. An important area of emphasis is the development and utilization of advanced energy sources, including highly energetic chemical reactions, solar energy, and processes based on fission, fusion, and antimatter. The Propulsion Research Laboratory is vital for developing the advanced propulsion technologies needed to open up the space frontier, and sets the stage of research that could revolutionize space transportation for a broad range of applications.

  8. SU-F-T-442: Dose Distribution Comparison for Post-Laryngectomy Stoma Area Between Conventional AP and VMAT Plans with Or Without Bolus

    Energy Technology Data Exchange (ETDEWEB)

    Lee, B [University of California, Los Angeles, Los Angeles, CA (United States); Zhang, J; Cho-Lim, J [VA Long Beach Healthcare System, Long Beach, CA (United States); University of California, Irvine, Orange, CA (United States); Leu, M [VA Greater Los Angeles Healthcare System, Los Angeles, CA (United States); Inouye, W [VA Long Beach Healthcare System, Long Beach, CA (United States); Lorentz, W [University of California, Los Angeles, Los Angeles, CA (United States); VA Greater Los Angeles Healthcare System, Los Angeles, CA (United States); Lee, S [University of California, Los Angeles, Los Angeles, CA (United States); VA Long Beach Healthcare System, Long Beach, CA (United States); VA Greater Los Angeles Healthcare System, Los Angeles, CA (United States)

    2016-06-15

    Purpose: To compare dose distributions of conventional AP vs. VMAT treatment plans with or without bolus around post-laryngectomy stoma. Methods: Radiation dose coverage for post-laryngectomy stoma was analyzed using a set of real-case CT-simulation images. After meticulous contouring of the catheter cuff, stoma lumen, peri-stoma skin and subclinical tumor bed at the larynx, the resulting dosimetry plans were analyzed with or without a 5 mm bolus placement. Wet gauze was used to minimize the effect of any air gap. Four plans were generated: AP superclavicular (SCV) plan with or without bolus, and VMAT plan with or without bolus. A dose of 60Gy in 30 fractions was prescribed at 3 cm depth for AP SCV plan, and to 95% of the PTV volume for VMAT plan. Results: For the conventional AP SCV plan, the peri-stoma skin dose is sensitive to bolus placement as well as air gap compensation by wetted gauze (V95% of 20.7%, 33.0% and 94.8% for no bolus, bolus without and with air gap compensation, respectively). For stoma lumen, the dose drops off rapidly in depth. The catheter cuff may have certain dose-buildup effect, but air gap around it and under the bolus placed can pose a more serious problem. The dose distributions of the two VMAT plans are moderately different for peri-stoma skin (V95% of 95.0% with bolus and air gap compensation, and 82.3% without bolus), but nearly identical for stoma lumen (V95% of 91.5% and 92.0%, respectively). VMAT allows beamlets with different angles of incidence that helped achieve such dose distribution around the stoma even without bolus placement. Conclusion: Overall, the dose coverage around the stoma in the VMAT plan is better than the conventional AP SCV plan. To achieve optimal dose distribution, it is still recommended to place physical bolus and reduce the air gaps.

  9. A Method for Direct Fabrication of a Lingual Splint for Management of Pediatric Mandibular Fractures

    Directory of Open Access Journals (Sweden)

    Gerardo P. Romeo, DDS, MD

    2013-10-01

    Full Text Available Summary: Pediatric mandibular fractures have successfully been managed in various ways. The use of a lingual splint is one such option. The typical indirect method for acrylic lingual splint fabrication involves obtaining dental impressions. Dental models are produced from those impressions so that model surgery may be performed. The splint is then made on those models using resin powder and liquid monomer in a wet laboratory and transferred to the patient. Obvious limitations to this technique exist for both patient and operator. We present a technique for direct, intraoperative, fabrication of a splint using commercially available light-cured material that avoids some of the shortcomings of the indirect method. Recommendations are made based on available material safety information.

  10. MR liver imaging after bolus administration of Teslascan

    International Nuclear Information System (INIS)

    Costa, S.; Marti-Bonmati, L.; Delgado, F.; Torregrosa, A.

    2003-01-01

    Mn-DPDP (Teslascan. Amersham-Health) improves the detection of small hepatic lesions and the accuracy with which certain focal lesions can be characterized. Slow infusion (2-3 ml per minute) is the accepted European standard for its administration. Our aim was to evaluate the efficiency of bolus administration. A prospective MR evaluation at 0.5 was performed on 31 consecutive patients. A GE T1 sequence was performed on all before contrast administration. Teslascan was administered by rapid intravenous infusion (=1 ml/s), and the GE sequence was repeated and completed by an STIR sequence. Correlations between presence of cirrhosis and enhancement pattern of hepatic parenchyma, number of lesions detected before and after bolus administration, as well as lesion histology and degree of enhancement were all analyzed. Adverse clinical reactions as reported by patients were also noted. Cirrhotic liver was found in 49% of the patients. Enhancement was mainly heterogeneous with hypointense areas and heterogeneous with hypointense areas together with more greatly enhanced regenerative nodules. Enhancement of cirrhotic livers was homogeneous in a third of the cases. Non-cirrhotic patients exhibited a homogeneous hepatic mass in most cases,ith only one liver showing heterogeneous enhancement containing hypointense bands caused by necrotic debris having resulted from treated metastases. Enhancement pattern differences between cirrhotic and non-cirrhotic patients were statistically significant (p=0.001). In 20 of the 31 patients, solid focal lesions were detected. Sequences performed after bolus administration of contrast media detected more lesions than did those before administration. Combination of both post-administration sequences (T1 and STIR) detected the most lesions, with differences between it and pre-administration sequences being statistically significant (p=0.0014). There was observed a varying degree of lesion enhancement. Such variability was associated with the

  11. Control of lower incisor inclination with a completely customized lingual appliance for dentoalveolar compensation of class III malocclusion.

    Science.gov (United States)

    Lossdörfer, Stefan; Schwestka-Polly, Rainer; Wiechmann, Dirk

    2013-09-01

    Bracket slots and orthodontic archwires offering high dimensional precision are needed for fully customized lingual appliances. We aimed to investigate whether high-precision appliances of this type enable dentoalveolar compensation of class III malocclusion so that lower incisor inclination at the end of treatment will closely match the anticipated situation as defined in a pretreatment setup. This retrospective study included a total of 34 consecutive patients who had worn a fully customized lingual appliance to achieve dentoalveolar compensation for class III malocclusion by intermaxillary elastics, or proximal enamel reduction, or extraction of teeth in one or both jaws. Casts fabricated at different points in time were three-dimensionally scanned to analyze how precisely the lower incisor inclinations envisioned in the setup were implemented in clinical practice. Aside from minor deviations of ±3.75°, the lower incisor inclinations were clinically implemented as planned even in patients with major sagittal discrepancies. Treatment goals predefined in a setup of dentoalveolar compensation for class III malocclusion can be very precisely achieved via a customized lingual appliance. Correct planning can prevent undesirable lingual tipping of the lower incisors. This finding should not encourage a more liberal use of dentoalveolar compensation, but it should heighten clinicians' awareness of how essential it is to sufficiently consider the individual anatomy of the dentoalveolar complex during treatment planning.

  12. Causes of death after fluid bolus resuscitation: new insights from FEAST.

    Science.gov (United States)

    Myburgh, John; Finfer, Simon

    2013-03-14

    The Fluid Expansion as Supportive Therapy (FEAST study) was an extremely well conducted study that gave unexpected results. The investigators had reported that febrile children with impaired perfusion treated in low-income countries without access to intensive care are more likely to die if they receive bolus resuscitation with albumin or saline compared with no bolus resuscitation at all. In a secondary analysis of the trial, published in BMC Medicine, the authors found that increased mortality was evident in patients who presented with clinical features of severe shock in isolation or in conjunction with features of respiratory or neurological failure. The cause of excess deaths was primarily refractory shock and not fluid overload. These features are consistent with a potential cardiotoxic or ischemia-reperfusion injury following resuscitation with boluses of intravenous fluid. Although these effects may have been amplified by the absence of invasive monitoring, mechanical ventilation or vasopressors, the results provide compelling insights into the effects of intravenous fluid resuscitation and potential adverse effects that extend beyond the initial resuscitation period. These data add to the increasing body of literature about the safety and efficacy of intravenous resuscitation fluids, which may be applicable to management of other populations of critically ill patients.

  13. Comparison of Aero-Propulsive Performance Predictions for Distributed Propulsion Configurations

    Science.gov (United States)

    Borer, Nicholas K.; Derlaga, Joseph M.; Deere, Karen A.; Carter, Melissa B.; Viken, Sally A.; Patterson, Michael D.; Litherland, Brandon L.; Stoll, Alex M.

    2017-01-01

    NASA's X-57 "Maxwell" flight demonstrator incorporates distributed electric propulsion technologies in a design that will achieve a significant reduction in energy used in cruise flight. A substantial portion of these energy savings come from beneficial aerodynamic-propulsion interaction. Previous research has shown the benefits of particular instantiations of distributed propulsion, such as the use of wingtip-mounted cruise propellers and leading edge high-lift propellers. However, these benefits have not been reduced to a generalized design or analysis approach suitable for large-scale design exploration. This paper discusses the rapid, "design-order" toolchains developed to investigate the large, complex tradespace of candidate geometries for the X-57. Due to the lack of an appropriate, rigorous set of validation data, the results of these tools were compared to three different computational flow solvers for selected wing and propulsion geometries. The comparisons were conducted using a common input geometry, but otherwise different input grids and, when appropriate, different flow assumptions to bound the comparisons. The results of these studies showed that the X-57 distributed propulsion wing should be able to meet the as-designed performance in cruise flight, while also meeting or exceeding targets for high-lift generation in low-speed flight.

  14. A prospective, randomized, blinded-endpoint, controlled study - continuous epidural infusion versus programmed intermittent epidural bolus in labor analgesia

    Directory of Open Access Journals (Sweden)

    Joana Nunes

    Full Text Available Abstract Background: There is evidence that administration of a programmed intermittent epidural bolus (PIEB compared to continuous epidural infusion (CEI leads to greater analgesia efficacy and maternal satisfaction with decreased anesthetic interventions. Methods: In this study, 166 women with viable pregnancies were included. After an epidural loading dose of 10 mL with Ropivacaine 0.16% plus Sufentanil 10 µg, parturient were randomly assigned to one of three regimens: A - Ropivacaine 0.15% plus Sufentanil 0.2 µg/mL solution as continuous epidural infusion (5 mL/h, beginning immediately after the initial bolus; B - Ropivacaine 0.1% plus Sufentanil 0.2 µg/mL as programmed intermittent epidural bolus and C - Same solution as group A as programmed intermittent epidural bolus. PIEB regimens were programmed as 10 mL/h starting 60 min after the initial bolus. Rescue boluses of 5 mL of the same solution were administered, with the infusion pump. We evaluated maternal satisfaction using a verbal numeric scale from 0 to 10. We also evaluated adverse, maternal and neonatal outcomes. Results: We analyzed 130 pregnants (A = 60; B = 33; C = 37. The median verbal numeric scale for maternal satisfaction was 8.8 in group A; 8.6 in group B and 8.6 in group C (p = 0.83. We found a higher caesarean delivery rate in group A (56.7%; p = 0.02. No differences in motor block, instrumental delivery rate and neonatal outcomes were observed. Conclusions: Maintenance of epidural analgesia with programmed intermittent epidural bolus is associated with a reduced incidence of caesarean delivery with equally high maternal satisfaction and no adverse outcomes.

  15. [Effectiveness of the GlideScope video laryngoscope in a case of unexpected difficult airway due to lingual tonsil hypertrophy].

    Science.gov (United States)

    Cruz, P; Alarcón, L; Del Castillo, T; Cabrerizo, P; Díaz, S

    2015-05-01

    Lingual tonsil hypertrophy can cause varying degrees of airway obstruction and is considered a risk factor for difficult mask ventilation and tracheal intubation. We report a case of unexpected difficult airway in a patient with unknown lingual tonsil hypertrophy that was solved with the use of the GlideScope video laryngoscope. Copyright © 2014 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  16. Lingual orthodontics for children and adolescents: improvement of the indirect bonding protocol

    Science.gov (United States)

    2013-01-01

    Introduction Demineralization of the dental enamel is a finding associated with fixed orthodontic treatment. When an indirect bonding procedure is used in children and adolescents the area beneath the bracket base may be affected. Aim To evaluate if the addition of an extra layer of a hydrophilic resin, to a conventional indirect bonding protocol, can reduce the incidence of demineralization beneath the bracket base. Methods 40 patients under 18 years of age were treated with completely customized lingual appliances. Two different bonding protocols were used either with or without the application of an additional layer of hydrophilic resin. Demineralization beneath the bracket base, after de-bonding, was evaluated by standardized intra-oral photographs. Results The addition of an extra layer of a hydrophilic resin helps to reduce the number of demineralized areas beneath the bracket bases significantly (three times less). The severity of the few remaining defects were minor and without any clinical consequence. Conclusion When bonding a completely customized lingual appliance in children and adolescents, an extra layer of a hydrophilic resin should be added to the teeth. PMID:24025345

  17. Evaluation of surface and shallow depth dose reductions using a Superflab bolus during conventional and advanced external beam radiotherapy.

    Science.gov (United States)

    Yoon, Jihyung; Xie, Yibo; Zhang, Rui

    2018-03-01

    The purpose of this study was to evaluate a methodology to reduce scatter and leakage radiations to patients' surface and shallow depths during conventional and advanced external beam radiotherapy. Superflab boluses of different thicknesses were placed on top of a stack of solid water phantoms, and the bolus effect on surface and shallow depth doses for both open and intensity-modulated radiotherapy (IMRT) beams was evaluated using thermoluminescent dosimeters and ion chamber measurements. Contralateral breast dose reduction caused by the bolus was evaluated by delivering clinical postmastectomy radiotherapy (PMRT) plans to an anthropomorphic phantom. For the solid water phantom measurements, surface dose reduction caused by the Superflab bolus was achieved only in out-of-field area and on the incident side of the beam, and the dose reduction increased with bolus thickness. The dose reduction caused by the bolus was more significant at closer distances from the beam. Most of the dose reductions occurred in the first 2-cm depth and stopped at 4-cm depth. For clinical PMRT treatment plans, surface dose reductions using a 1-cm Superflab bolus were up to 31% and 62% for volumetric-modulated arc therapy and 4-field IMRT, respectively, but there was no dose reduction for Tomotherapy. A Superflab bolus can be used to reduce surface and shallow depth doses during external beam radiotherapy when it is placed out of the beam and on the incident side of the beam. Although we only validated this dose reduction strategy for PMRT treatments, it is applicable to any external beam radiotherapy and can potentially reduce patients' risk of developing radiation-induced side effects. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  18. SU-F-T-325: On the Use of Bolus in Dosimetry and Dose Reduction for Pacemaker and Defibrillator

    International Nuclear Information System (INIS)

    Liu, W; Kenneth, R; Higgins, S; Nath, R; Zhu, D; Trumpore, S; Chen, Z

    2016-01-01

    Purpose: Special attention is required in planning and administering radiation therapy to patients with cardiac implantable electronic devices (CIEDs), such as pacemaker and defibrillator. The range of dose to CIEDs that can induce malfunction is very large among CIEDs. Significant defects have been reported at dose as low as 0.15Gy. Failures causing discomfort have been reported at dose as low as 0.05Gy. Therefore, accurate estimation of dose to CIED and dose reduction are both important even if the dose is expected to be less than the often-used 2Gy limit. We investigate the use of bolus in in vivo dosimetry for CIEDs. Methods: In our clinic, high-energy beams (>10MV) are not used for patients with CIED due to neutron production. Solid water phantom measurements of out-of-field dose for a 6MV beam were performed using parallel plate chamber at different depth with and without 2cm bolus covering the chamber. In vivo dosimetry at skin surface above the pacemaker was performed with and without bolus for 3 patients with pacemaker <5cm from the field edge. Results: Chamber measured dose at depth ∼1 to 1.5cm below the skin surface, where the CIED is normally located, was reduced by ∼6% – 20% with bolus. The dose reduction became smaller at deeper depth. In vivo dosimetry at skin surface also yielded ∼20% – 60% lower dose when using bolus for the 3 patients. In general, TPS calculation underestimated the dose. The dose measured with bolus is closer to the dose at the depth of the pacemaker and less affected by contaminant electrons and linac head leakage. Conclusion: In vivo CIED dose measurements should be performed with 1 to 2cm bolus covering the dosimeter on the skin above the CIED for more accurate CIED dose estimation. The use of bolus also reduces the dose delivered to CIED.

  19. SU-F-T-325: On the Use of Bolus in Dosimetry and Dose Reduction for Pacemaker and Defibrillator

    Energy Technology Data Exchange (ETDEWEB)

    Liu, W; Kenneth, R; Higgins, S; Nath, R [Yale University School of Medicine, New Haven, CT (United States); Zhu, D [Saint Thomas Hospital, Murfreesboro, TN (United States); Trumpore, S [Yale-New Haven Hospital, New Haven, CT (United States); Chen, Z [Yale New Haven Hospital, New Haven, CT (United States)

    2016-06-15

    Purpose: Special attention is required in planning and administering radiation therapy to patients with cardiac implantable electronic devices (CIEDs), such as pacemaker and defibrillator. The range of dose to CIEDs that can induce malfunction is very large among CIEDs. Significant defects have been reported at dose as low as 0.15Gy. Failures causing discomfort have been reported at dose as low as 0.05Gy. Therefore, accurate estimation of dose to CIED and dose reduction are both important even if the dose is expected to be less than the often-used 2Gy limit. We investigate the use of bolus in in vivo dosimetry for CIEDs. Methods: In our clinic, high-energy beams (>10MV) are not used for patients with CIED due to neutron production. Solid water phantom measurements of out-of-field dose for a 6MV beam were performed using parallel plate chamber at different depth with and without 2cm bolus covering the chamber. In vivo dosimetry at skin surface above the pacemaker was performed with and without bolus for 3 patients with pacemaker <5cm from the field edge. Results: Chamber measured dose at depth ∼1 to 1.5cm below the skin surface, where the CIED is normally located, was reduced by ∼6% – 20% with bolus. The dose reduction became smaller at deeper depth. In vivo dosimetry at skin surface also yielded ∼20% – 60% lower dose when using bolus for the 3 patients. In general, TPS calculation underestimated the dose. The dose measured with bolus is closer to the dose at the depth of the pacemaker and less affected by contaminant electrons and linac head leakage. Conclusion: In vivo CIED dose measurements should be performed with 1 to 2cm bolus covering the dosimeter on the skin above the CIED for more accurate CIED dose estimation. The use of bolus also reduces the dose delivered to CIED.

  20. Is the Lingual Fracture Line Influenced by the Mandibular Canal or the Mylohyoid Groove During a Bilateral Sagittal Split Osteotomy? A Human Cadaveric Study

    NARCIS (Netherlands)

    Mensink, Gertjan; Gooris, Peter J. J.; Bergsma, Eelco J.; Frank, Michael H.; van Gemert, Jan T. M.; van Merkesteyn, J. P. Richard

    2014-01-01

    Purpose: Although the bilateral sagittal split osteotomy (BSSO) is a routinely performed procedure, exact control of the lingual fracture line remains problematic. The purpose of this study was to determine the various lingual splitting patterns in cadaveric human mandibles after a BSSO and the

  1. Comparison of rate of En masse retraction and anchorage loss in conventional labial appliance with labial and lingual force: A clinical study

    Directory of Open Access Journals (Sweden)

    Dilshad Quraishi

    2018-01-01

    Full Text Available Aims: The rate of en masse retraction and anchorage loss were compared between labial appliance with lingual force and conventional labial appliance. Subjects and Methods: The sample consists of 14 patients and they were divided into two groups. In Group 1 – labial appliance with lingual force, elastomeric chain was placed from the palatal surface of the canines to the palatal surface of the molars. In Group 2 – labial appliance with labial force, elastomeric chain was placed from the crimpable hook distal to lateral incisor to the molar tube hooks. The rate of en masse retraction and anchorage loss was calculated for both the groups during retraction in dental casts (R0, initial; R1, 4 weeks; R2, 8 weeks; and R3, 12 weeks. Statistical Analysis Used: Student's paired t-test. Results: The rate of retraction was faster and anchorage loss was lower with labial appliance with lingual force, i.e., Group 1. The difference of anchorage loss in Group 1 and Group 2 shows t = 4.824 and P value= 0.000, which is statistically highly significant. The difference of rate of retraction in Group 1 and Group 2 shows t = 3.573 and P value = 0.004, which is statistically signifcant. Conclusions: The rate of retraction was faster and anchorage loss was lower with labial appliance with lingual force, thus indicating that this new technique of space closure utilizes biomechanical advantage of lingual force in conventional labial appliance.

  2. Optimization of a beam shaping bolus for superficial microwave hyperthermia waveguide applicators using a finite element method

    International Nuclear Information System (INIS)

    Kumaradas, J Carl; Sherar, Michael D

    2003-01-01

    Temperature inhomogeneity in hyperthermia treatments often limits the total thermal dose that can be delivered to the tumour region. To reduce such inhomogeneities, a prototype dynamically modifiable square array of saline-filled patches which attenuate microwave energy was developed for superficial treatments that use external microwave applicators. The array was situated inside the coupling water bolus that is often used with external applicators. The prototype has been previously tested clinically with promising results. A more complete theoretical analysis of the performance of this new bolus design and improvements to its design by modelling are presented here. The analysis was performed by performing five iterative simulations of the SAR pattern produced inside a tissue structure by a waveguide applicator with a water bolus containing the dynamic patch array attached. Between iterations the patch array configuration was modified in an attempt to improve the ability of the bolus to confine heating to an 'L'-shaped tumour region. These simulations were performed using the finite element method. The steady-state temperature profile was then computed using a finite element method based simulation of heat transfer that assumed a given applicator power level and water bolus temperature. Several iterations of these heat transfer simulations were performed with varying applicator power level and water bolus temperature to improve the confinement of heating to the target region. The analysis showed that the dynamic patch array should be capable of conforming heating to an 'L'-shaped target tumour region while limiting the heating to the surrounding normal tissue to an acceptable level

  3. Radionuclide esophageal transit of a liquid bolus: A reappraisal

    International Nuclear Information System (INIS)

    Holloway, R.H.; Lange, R.C.; Magyar, L.; Greene, R.; McCallum, R.W.

    1984-01-01

    Measurement of radionuclide esophageal transit (RT) using a liquid bolus has been suggested as a screening test for esophageal motor disorders (EMD). The authors prospectively evaluated RT in 49 patients referred for esophageal manometry. Ten subjects with normal manometry served as controls. RT was performed using two 10 ml boluses of water labeled with 250 μCi /sup 99m/Tc-sulfur colloid. Patients were studied supine and the swallow sequences framed in 1 second intervals. Transit time was measured from the time of entry to the time of exit from the esophagus. Mean transit time in normal subjects was 9.1 +- 2.1 (SD) sec. The test was abnormal if the transit time was prolonged (> 15 sec) in at least 1 of 2 swallows. RT agreed with manometry in 36/49 patients (75%), including 9/9 achalasics, 3/3 diffuse esophageal spasm, 3/7 'nutcracker esophagus' and 7/8 non-specific motor disorders (NSMD). 4/18 patients with normal manometry had abnormal RT. 9/31 patients with abnormal manometry had normal RT, including 4/7 nutcracker esophagus, 3/3 hypertrensive LES, 1/1 scleroderma and 1/8 NSMD. Sensitivity of RT was 70% and specificity 77%. The false positive rate was 15% and the false negative rate 39%. The authors conclude the following: 1) RT identifies patients with absent or impaired peristalsis; 2) There is substantial incidence of false negatives among patients with manometric disorders but normal peristalsis; and 3) Abnormal RT did occur in some patients with normal menometry. RT using a liquid bolus may not be sensitive enough as a screening test for EMD, but it may be an important adjunct to manometry

  4. Perception of Diabetic Patients Regarding Basal Bolus Insulin Injections and Outcome of its Use

    International Nuclear Information System (INIS)

    Shahid, M.; Sarfraz, A.; Mahar, S. A.; Alam, M.; Shaikh, S.; Shahid, N.

    2016-01-01

    Objective: To assess the perceptions regarding basal bolus insulin injections and the changes in blood glucose levels and glycosylated hemoglobin (HbA1c) before and after 3 months of such treatment in diabetic patients. Study Design: Quasi-experimental study. Place and Duration of Study: Department of Endocrinology, Liaquat National Hospital, Karachi, from December 2014 to March 2015. Methodology: A total of 222 diabetic patients started on basal bolus insulin injection were enrolled and asked to answer 17 questions. Those with complications of diabetes were excluded. Fasting blood glucose (FBS), random blood glucose (RBS) and HbA1c levels were checked initially, and after 3 months of getting basal bolus insulin. Paired t-test and chi-square test were used for determining p-value with significance at p < 0.05. Results: Majority (n=217, 97.7 percentage) of the patients were previously taking other insulins. Before starting this treatment, the mean FBS was 260.5 ± 52.2 mg/dl, RBS was 385.5 percentage 47.61 mg/dl and HbA1c was 12.76 percentage 1.92 percentage. After 3 months of treatment, FBS improved to 117.9 ± 14.2 mg/dl, RBS was 156.7 ± 17.09 mg/dl and HbA1c was 7.72 ± 4.41 percentage (p < 0.001). Two hundred and sixteen (97.3 percentage) patients believed that basal bolus insulin was started as their diabetes worsened; 15 (70.70 percentage) thought that their blood glucose control would improve with the use of this form of insulin. One hundred and ninety four (87.4 percentage) had fear of needle injections. Perceptions regarding hypoglycemia with this form of insulin were observed in 157 (70.7 percentage). One hundred and twenty seven (84.1 percentage) of the females and 51 (71.8 percentage) of the males thought that the basal bolus insulin regimen was too expensive (p=0.032). Conclusion: There were many misconceptions in patients who were started on basal bolus insulin. Marked improvement in blood glucose levels and HbA1c were observed after the use of this

  5. Ocular Dynamics of Bolus Ingestion of Eleis guineensis Sap (Palm ...

    African Journals Online (AJOL)

    Elaeis guineensis), and is widely consumed among the various ethnic nationalities in Nigeria. The effect of bolus ingestion of 600ml, palm wine was undertaken so as to determine its ocular dynamics in healthy volunteers. Results showed that ...

  6. Comparison of first-pass and second-bolus dynamic susceptibility perfusion MRI in brain tumors

    International Nuclear Information System (INIS)

    Spampinato, M.V.; Besenski, Nada; Rumboldt, Zoran; Wooten, Caroline; Dorlon, Margaret

    2006-01-01

    Our goal was to evaluate whether the T1 shortening effect caused by contrast leakage into brain tumors, a well-known confounding effect in the quantification of relative cerebral blood volume (rCBV) measurements, may be corrected by the administration of a predose of gadolinium-DTPA. As part of their presurgical imaging protocol, 25 patients with primary brain tumors underwent two consecutive dynamic susceptibility-weighted contrast-enhanced (DSC) perfusion MR studies. Intratumoral rCBV measurements and normalized rCBV values obtained during the first-pass and second-bolus studies were compared (Wilcoxon signed-ranks test). The frequency of relatively increased rCBV ratios on the second-bolus study was compared between enhancing and non-enhancing neoplasms (Fisher's exact test). Postprocessing perfusion studies were evaluated for image quality on a scale of 0-3 (Wilcoxon signed-ranks test). Four studies were excluded due to unacceptable image quality. Mean normalized rCBVs were 9.04 (SD 4.64) for the first-pass and 7.99 (SD 3.84) for the second-bolus study. There was no statistically significant difference between the two perfusion studies in either intratumoral rCBV (P=0.237) or rCBV ratio (P=0.181). Five enhancing and four non-enhancing tumors showed a relative increase in rCBV ratio on the second-bolus study, without a significant difference between the groups. Image quality was not significantly different between perfusion studies. Our results did not demonstrate a significant difference between first-pass and second-bolus rCBV measurements in DSC perfusion MR imaging. The administration of a predose of gadolinium-DTPA does not appear to be an efficient way of compensating for the underestimation of intratumoral rCBV values due to the T1 shortening effect. (orig.)

  7. Review of adverse reactions, including anaphylaxis, in 4,260 intravenous bolus injections

    International Nuclear Information System (INIS)

    Kanal, E.; Applegate, G.R.; Gillen, C.P.

    1990-01-01

    This paper evaluates the incidence and type of adverse reactions to Gd-DTPA (Magnevist) after bolus administration in an active clinical MR setting. Between May 1988 and March 1990, 4,260 bolus intravenous injections of Gd-DTPA, 0.1 mmol/kg, were administered during clinical MR examinations. Patient tolerance and reactions were recorded in each instance. All cases of suspected local infiltration were excluded from this study. Review of this data revealed 15 instances of nausea and 12 of emesis following contrast administration. In addition, there were five or fewer cases of associated headaches, dizziness, odd tastes, seizures (with prior seizure histories) mild chest pain, palpitations, hives, or wheezing

  8. Brief review on pulse laser propulsion

    Science.gov (United States)

    Yu, Haichao; Li, Hanyang; Wang, Yan; Cui, Lugui; Liu, Shuangqiang; Yang, Jun

    2018-03-01

    Pulse laser propulsion (PLP) is an advanced propulsion concept can be used across a variety of fields with a wide range of applications. PLP reflects superior payload as well as decreased launch costs in comparison with other conventional methods of producing thrust, such as chemical propulsion or electric propulsion. Numerous researchers have attempted to exploit the potential applications of PLP. This paper first reviews concepts relevant to PLP, including the propulsion modes, breakdown regimes, and propulsion efficiency; the propulsion targets for different materials with the pulse laser are then discussed in detail, including the propulsion of solid and liquid microspheres. PLP applications such as the driven microsatellite, target surface particle removal, and orbital debris removal are also discussed. Although the PLP has been applied to a variety of fields, further research is yet warranted to establish its application in the aerospace field.

  9. NASA Electric Propulsion System Studies

    Science.gov (United States)

    Felder, James L.

    2015-01-01

    An overview of NASA efforts in the area of hybrid electric and turboelectric propulsion in large transport. This overview includes a list of reasons why we are looking at transmitting some or all of the propulsive power for the aircraft electrically, a list of the different types of hybrid-turbo electric propulsion systems, and the results of 4 aircraft studies that examined different types of hybrid-turbo electric propulsion systems.

  10. Impaired bolus transit across the esophagogastric junction in postfundoplication dysphagia

    NARCIS (Netherlands)

    Scheffer, R. C. H.; Samsom, M.; Haverkamp, A.; Oors, J.; Hebbard, G. S.; Gooszen, H. G.

    2005-01-01

    This study assessed the effect of fundoplication on liquid and solid bolus transit across the esophagogastric junction (EGJ) in relation to EGJ dynamics and dysphagia. Twelve patients with gastro-esophageal reflux disease (GERD) were studied before and after fundoplication. Concurrent

  11. Electrical characterization of bolus material as phantom for use in electrical impedance and computed tomography fusion imaging

    Directory of Open Access Journals (Sweden)

    Parvind Kaur Grewal

    2014-04-01

    Full Text Available Phantoms are widely used in medical imaging to predict image quality prior to clinical imaging. This paper discusses the possible use of bolus material, as a conductivity phantom, for validation and interpretation of electrical impedance tomography (EIT images. Bolus is commonly used in radiation therapy to mimic tissue. When irradiated, it has radiological characteristics similar to tissue. With increased research interest in CT/EIT fusion imaging there is a need to find a material which has both the absorption coefficient and electrical conductivity similar to biological tissues. In the present study the electrical properties, specifically resistivity, of various commercially available bolus materials were characterized by comparing their frequency response with that of in-vivo connective adipose tissue. It was determined that the resistivity of Gelatin Bolus is similar to in-vivo tissue in the frequency range 10 kHz to 1MHz and therefore has potential to be used in EIT/CT fusion imaging studies.

  12. The Impact of Injector-Based Contrast Agent Administration on Bolus Shape and Magnetic Resonance Angiography Image Quality.

    Science.gov (United States)

    Jost, Gregor; Endrikat, Jan; Pietsch, Hubertus

    2017-01-01

    To compare injector-based contrast agent (CA) administration with hand injection in magnetic resonance angiography (MRA). Gadobutrol was administered in 6 minipigs with 3 protocols: (a) hand injection (one senior technician), (b) hand injection (6 less-experienced technicians), and (c) power injector administration. The arterial bolus shape was quantified by test bolus measurements. A head and neck MRA was performed for quantitative and qualitative comparison of signal enhancement. A significantly shorter time to peak was observed for protocol C, whereas no significant differences between protocols were found for peak height and bolus width. However, for protocol C, these parameters showed a much lower variation. The MRA revealed a significantly higher signal-to-noise ratio for injector-based administration. A superimposed strong contrast of the jugular vein was found in 50% of the hand injections. Injector-based CA administration results in a more standardized bolus shape, a higher vascular contrast, and a more robust visualization of target vessels.

  13. The Impact of Injector-Based Contrast Agent Administration on Bolus Shape and Magnetic Resonance Angiography Image Quality

    Directory of Open Access Journals (Sweden)

    Gregor Jost

    2017-04-01

    Full Text Available Objective: To compare injector-based contrast agent (CA administration with hand injection in magnetic resonance angiography (MRA. Methods: Gadobutrol was administered in 6 minipigs with 3 protocols: (a hand injection (one senior technician, (b hand injection (6 less-experienced technicians, and (c power injector administration. The arterial bolus shape was quantified by test bolus measurements. A head and neck MRA was performed for quantitative and qualitative comparison of signal enhancement. Results: A significantly shorter time to peak was observed for protocol C, whereas no significant differences between protocols were found for peak height and bolus width. However, for protocol C, these parameters showed a much lower variation. The MRA revealed a significantly higher signal-to-noise ratio for injector-based administration. A superimposed strong contrast of the jugular vein was found in 50% of the hand injections. Conclusions: Injector-based CA administration results in a more standardized bolus shape, a higher vascular contrast, and a more robust visualization of target vessels.

  14. A prospective, randomized, blinded-endpoint, controlled study - continuous epidural infusion versus programmed intermittent epidural bolus in labor analgesia.

    Science.gov (United States)

    Nunes, Joana; Nunes, Sara; Veiga, Mariano; Cortez, Mara; Seifert, Isabel

    2016-01-01

    There is evidence that administration of a programmed intermittent epidural bolus (PIEB) compared to continuous epidural infusion (CEI) leads to greater analgesia efficacy and maternal satisfaction with decreased anesthetic interventions. In this study, 166 women with viable pregnancies were included. After an epidural loading dose of 10mL with Ropivacaine 0.16% plus Sufentanil 10μg, parturient were randomly assigned to one of three regimens: A - Ropivacaine 0.15% plus Sufentanil 0.2μg/mL solution as continuous epidural infusion (5mL/h, beginning immediately after the initial bolus); B - Ropivacaine 0.1% plus Sufentanil 0.2μg/mL as programmed intermittent epidural bolus and C - Same solution as group A as programmed intermittent epidural bolus. PIEB regimens were programmed as 10mL/h starting 60min after the initial bolus. Rescue boluses of 5mL of the same solution were administered, with the infusion pump. We evaluated maternal satisfaction using a verbal numeric scale from 0 to 10. We also evaluated adverse, maternal and neonatal outcomes. We analyzed 130 pregnants (A=60; B=33; C=37). The median verbal numeric scale for maternal satisfaction was 8.8 in group A; 8.6 in group B and 8.6 in group C (p=0.83). We found a higher caesarean delivery rate in group A (56.7%; p=0.02). No differences in motor block, instrumental delivery rate and neonatal outcomes were observed. Maintenance of epidural analgesia with programmed intermittent epidural bolus is associated with a reduced incidence of caesarean delivery with equally high maternal satisfaction and no adverse outcomes. Copyright © 2015 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

  15. Nuclear-microwave-electric propulsion

    International Nuclear Information System (INIS)

    Nordley, G.D.; Brown, W.C.

    1986-01-01

    Electric propulsion can move more mass through space than chemical propulsion by virtue of the higher exhaust velocities achieved by electric propulsion devices. This performance is achieved at the expense of very heavy power sources or very long trip times, which in turn create technical and economic penalties of varying severity. These penalties include: higher operations costs, delayed availability of the payload, and increased exposure to Van Allen Belt radiation. It is proposed to reduce these penalties by physically separating the power source from the propulsion and use microwave energy beaming technology, recently explored and partially developed/tested for Solar Power Satellite concept studies, as an extension cord. This paper summarizes the state of the art of the technology needed for space based beam microwave power cost/performance trades involved with the use beamed microwave/electric propulsion for some typical orbit transfer missions and offers some suggestions for additional work

  16. Caries outcomes after orthodontic treatment with fixed appliances: do lingual brackets make a difference?

    NARCIS (Netherlands)

    van der Veen, M.H.; Attin, R.; Schwestka-Polly, R.; Wiechmann, D.

    2010-01-01

    Orthodontic treatment with fixed appliances is considered a risk factor for the development of white spot caries lesions (WSL). Traditionally, brackets are bonded to the buccal surfaces. Lingual brackets are developing rapidly and have become more readily available. Buccal surfaces are considered to

  17. Precision multiloop (PM Design) with space closing circles for lingual orthodontics

    OpenAIRE

    Mugdha P Mankar; Achint Chachada; Harish Atram; Avanti Kulkarni

    2016-01-01

    The proficiency of ancient orthodontics has been benefitted colossally and is being continually promoted over the present, by use of multiple loop wires designed for correction of dentoalveolar malocclusions. The presented discussion provides an insight into a simple, frictionless biomechanical concept of anterior space closure in lingual orthodontics by means of precision multiloop design with incorporated space closing circles. A multiple loop wire design has been demonstrated where the ent...

  18. Amyotrophic lateral sclerosis: sonographic evaluation of dysphagia.

    Science.gov (United States)

    Tamburrini, S; Solazzo, A; Sagnelli, A; Del Vecchio, L; Reginelli, A; Monsorrò, M; Grassi, R

    2010-08-01

    The authors sought to determine the role of video ultrasonography (VUS) in the diagnostic assessment of dysphagia in patients with amyotrophic lateral sclerosis (ALS). Nine patients underwent simultaneous static and dynamic VUS examination and videofluoroscopy (VFS) of swallowing. At the static phase, VUS showed 5/9 patients had lingual atrophy. Abnormal bolus position was observed in 6/9 patients at VUS and 3/9 at VFS. Both techniques identified an inability to keep the bolus in the oral cavity in 4/9 patients. At the dynamic phase, reduced lingual movement was observed in 5/9 patients at VUS and 2/9 at VFS. Disorganised tongue movement was seen in 3/9 patients at VUS and in 2/9 at VFS. Fragmented swallowing was only visualised at VUS. Stagnation of ingested material was never visualised at VUS, whereas it was clearly depicted in 2/9 patients at VFS. VUS can be integrated into the diagnostic protocol for evaluating swallowing in patients with ALS, as it has higher sensitivity than VFS in assessing the dynamic factors that represent the early signs of dysphagia.

  19. A prospective, randomized, blinded-endpoint, controlled study – continuous epidural infusion versus programmed intermittent epidural bolus in labor analgesia

    Directory of Open Access Journals (Sweden)

    Joana Nunes

    2016-09-01

    Full Text Available Background: There is evidence that administration of a programmed intermittent epidural bolus (PIEB compared to continuous epidural infusion (CEI leads to greater analgesia efficacy and maternal satisfaction with decreased anesthetic interventions. Methods: In this study, 166 women with viable pregnancies were included. After an epidural loading dose of 10 mL with Ropivacaine 0.16% plus Sufentanil 10 μg, parturient were randomly assigned to one of three regimens: A – Ropivacaine 0.15% plus Sufentanil 0.2 μg/mL solution as continuous epidural infusion (5 mL/h, beginning immediately after the initial bolus; B – Ropivacaine 0.1% plus Sufentanil 0.2 μg/mL as programmed intermittent epidural bolus and C – Same solution as group A as programmed intermittent epidural bolus. PIEB regimens were programmed as 10 mL/h starting 60 min after the initial bolus. Rescue boluses of 5 mL of the same solution were administered, with the infusion pump. We evaluated maternal satisfaction using a verbal numeric scale from 0 to 10. We also evaluated adverse, maternal and neonatal outcomes. Results: We analyzed 130 pregnants (A = 60; B = 33; C = 37. The median verbal numeric scale for maternal satisfaction was 8.8 in group A; 8.6 in group B and 8.6 in group C (p = 0.83. We found a higher caesarean delivery rate in group A (56.7%; p = 0.02. No differences in motor block, instrumental delivery rate and neonatal outcomes were observed. Conclusions: Maintenance of epidural analgesia with programmed intermittent epidural bolus is associated with a reduced incidence of caesarean delivery with equally high maternal satisfaction and no adverse outcomes. Resumo: Justificativa: Há evidências de que a administração de um bolus epidural intermitente programado (BEIP comparada à infusão epidural contínua (IEC resulta em maior eficácia da analgesia e da satisfação materna, com redução das intervenções anestésicas. Métodos: Neste estudo, 166

  20. Congenital Midline Tongue Base Mass in An Infant: Lingual Hamartoma

    OpenAIRE

    Fadzilah, Noraziana; Azman, Mawaddah; See, Goh Bee

    2016-01-01

    Lingual hamartoma is a rare finding of congenital midline posterior tongue mass. The lesion may be seen as a single anomaly or maybe associated with syndrome especially the Oral Facial Digital Syndrome (OFDS). Here, we report an otherwise normal and healthy two-month-old boy with a congenital midline base of tongue mass presented with snoring and episodic vomiting since the age of 1 month. Tumour excision from the area of foramen of caecum recovered a pinkish pedunculated tumour. Histopatholo...

  1. Optimum cycle frequencies in hand-rim wheelchair propulsion. Wheelchair propulsion technique

    NARCIS (Netherlands)

    van der Woude, L H; Veeger, DirkJan (H. E. J.); Rozendal, R H; Sargeant, A J

    1989-01-01

    To study the effect of different cycle frequencies on cardio-respiratory responses and propulsion technique in hand-rim wheelchair propulsion, experienced wheelchair sportsmen (WS group; n = 6) and non-wheelchair users (NW group; n = 6) performed wheelchair exercise tests on a motor-driven

  2. Effect of workload setting on propulsion technique in handrim wheelchair propulsion

    NARCIS (Netherlands)

    van Drongelen, Stefan; Arnet, Ursina; Veeger, DirkJan (H E. J); van der Woude, Lucas H. V.

    Objective: To investigate the influence of workload setting (speed at constant power, method to impose power) on the propulsion technique (i.e. force and timing characteristics) in handrim wheelchair propulsion. Method: Twelve able-bodied men participated in this study. External forces were measured

  3. Laser Propulsion - Quo Vadis

    International Nuclear Information System (INIS)

    Bohn, Willy L.

    2008-01-01

    First, an introductory overview of the different types of laser propulsion techniques will be given and illustrated by some historical examples. Second, laser devices available for basic experiments will be reviewed ranging from low power lasers sources to inertial confinement laser facilities. Subsequently, a status of work will show the impasse in which the laser propulsion community is currently engaged. Revisiting the basic relations leads to new avenues in ablative and direct laser propulsion for ground based and space based applications. Hereby, special attention will be devoted to the impact of emerging ultra-short pulse lasers on the coupling coefficient and specific impulse. In particular, laser sources and laser propulsion techniques will be tested in microgravity environment. A novel approach to debris removal will be discussed with respect to the Satellite Laser Ranging (SRL) facilities. Finally, some non technical issues will be raised aimed at the future prospects of laser propulsion in the international community

  4. Critical Propulsion Components. Volume 1; Summary, Introduction, and Propulsion Systems Studies

    Science.gov (United States)

    2005-01-01

    Several studies have concluded that a supersonic aircraft, if environmentally acceptable and economically viable, could successfully compete in the 21st century marketplace. However, before industry can commit to what is estimated as a 15 to 20 billion dollar investment, several barrier issues must be resolved. In an effort to address these barrier issues, NASA and Industry teamed to form the High-Speed Research (HSR) program. As part of this program, the Critical Propulsion Components (CPC) element was created and assigned the task of developing those propulsion component technologies necessary to: (1) reduce cruise emissions by a factor of 10 and (2) meet the ever-increasing airport noise restrictions with an economically viable propulsion system. The CPC-identified critical components were ultra-low emission combustors, low-noise/high-performance exhaust nozzles, low-noise fans, and stable/high-performance inlets. Propulsion cycle studies (coordinated with NASA Langley Research Center sponsored airplane studies) were conducted throughout this CPC program to help evaluate candidate components and select the best concepts for the more complex and larger scale research efforts. The propulsion cycle and components ultimately selected were a mixed-flow turbofan (MFTF) engine employing a lean, premixed, prevaporized (LPP) combustor coupled to a two-dimensional mixed compression inlet and a two-dimensional mixer/ejector nozzle. Due to the large amount of material presented in this report, it was prepared in four volumes; Volume 1: Summary, Introduction, and Propulsion System Studies, Volume 2: Combustor, Volume 3: Exhaust Nozzle, and Volume 4: Inlet and Fan/ Inlet Acoustic Team.

  5. The Nuclear Cryogenic Propulsion Stage

    Science.gov (United States)

    Houts, Michael G.; Kim, Tony; Emrich, William J.; Hickman, Robert R.; Broadway, Jeramie W.; Gerrish, Harold P.; Doughty, Glen; Belvin, Anthony; Borowski, Stanley K.; Scott, John

    2014-01-01

    The fundamental capability of Nuclear Thermal Propulsion (NTP) is game changing for space exploration. A first generation Nuclear Cryogenic Propulsion Stage (NCPS) based on NTP could provide high thrust at a specific impulse above 900 s, roughly double that of state of the art chemical engines. Characteristics of fission and NTP indicate that useful first generation systems will provide a foundation for future systems with extremely high performance. The role of the NCPS in the development of advanced nuclear propulsion systems could be analogous to the role of the DC-3 in the development of advanced aviation. Progress made under the NCPS project could help enable both advanced NTP and advanced Nuclear Electric Propulsion (NEP). Nuclear propulsion can be affordable and viable compared to other propulsion systems and must overcome a biased public fear due to hyper-environmentalism and a false perception of radiation and explosion risk.

  6. Occurrence and severity of enamel decalcification adjacent to bracket bases and sub-bracket lesions during orthodontic treatment with two different lingual appliances

    Science.gov (United States)

    Klang, Elisabeth; Helms, Hans-Joachim; Wiechmann, Dirk

    2016-01-01

    Summary Background: Using lingual enamel surfaces for bracket placement not only has esthetic advantages, but may also be suitable in terms of reducing frequencies of enamel decalcifications. Objective: To test the null-hypothesis that there is no significant difference in enamel decalcification or cavitation incidence adjacent to and beneath bracket bases between two lingual multi-bracket (MB) appliances that are different in terms of design, material composition, and manufacturing technology (group A: WIN, DW-LingualSystems; group B: Incognito, 3M-Unitek), taking into account patient- and treatment-related variables on white spot lesion (WSL) formation. Methods: Standardized, digital, top-view photographs of 630 consecutive subjects (16214 teeth; n Incognito = 237/6076 teeth; n WIN = 393/10138 teeth; mean age: 17.47±7.8; m/f 43.2/56.8%) with completed lingual MB treatment of the upper and lower permanent teeth 1–7 were screened for decalcification or cavitation adjacent to and beneath the bracket bases before and after treatment, scored from 0 to 7. Non-parametric ANOVA was used for main effects ‘appliance type’, ‘gender’, ‘treatment complexity’, ‘grouped age’ (≤16/>16 years), and ‘treatment duration’ as covariable, at an α-level of 5%. Results: About 2.57% [5.94%] of all teeth in group A [B] developed decalcifications. Subject-related incidence was 9.59% [16.17%] for upper incisors in group A [B], and 12.98% [25.74%] for all teeth 16–46. There were significant effects by gender, age, and treatment duration. Conclusion: The null-hypothesis was rejected: sub-bracket lesions were significantly less frequent in group A, while frequencies of WSL adjacent to brackets were not significantly affected by appliance type. In view of the overall low incidences of lingual post-orthodontic white-spot lesions, the use of lingual appliances is advocated as a valid strategy for a reduction of enamel decalcifications during orthodontic treatment. PMID

  7. Localization of Alpha-Keratin and Beta-Keratin (Corneous Beta Protein) in the Epithelium on the Ventral Surface of the Lingual Apex and Its Lingual Nail in the Domestic Goose (Anser Anser f. domestica) by Using Immunohistochemistry and Raman Microspectroscopy Analysis.

    Science.gov (United States)

    Skieresz-Szewczyk, Kinga; Jackowiak, Hanna; Buchwald, Tomasz; Szybowicz, Mirosław

    2017-08-01

    The epithelium of the ventral surface of the apex of the tongue in most birds is specified by the presence of the special superficial layer called lingual nail. The aim of the present study is to determine the localization of the alpha-keratin and beta-keratin (corneous beta protein) in this special epithelium in the domestic goose by using immunohistochemistry staining and the Raman spectroscopy analysis. Due to lack of commercially available antibodies to detect beta-keratin (corneous beta protein), the Raman spectroscopy was used as a specific tool to detect and describe the secondary structure of proteins. The immunohistochemical (IHC) detections reveal the presence of alpha-keratin in all layers of the epithelium, but significant differences in the distribution of the alpha-keratin in the epithelial layers appear. The staining reaction is stronger from the basal layer to the upper zone of the intermediate layer. The unique result is weak staining for the alpha-keratin in the lingual nail. Applications of the Raman spectroscopy as a complementary method not only confirmed results of IHC staining for alpha-keratin, but showed that this technique could be used to demonstrate the presence of beta-keratin (corneous beta protein). Functionally, the localization of alpha-keratin in the epithelium of the ventral surface of the lingual apex provides a proper scaffold for epithelial cells and promotes structural integrity, whereas the presence of beta-keratin (corneous beta protein) in the lingual nail, described also as exoskeleton of the ventral surface of the apex, endures mechanical stress. Anat Rec, 300:1361-1368, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  8. Study of dose modification in skin cancers induced by the kind of bolus used - Bibliography

    International Nuclear Information System (INIS)

    Camilleri, Jeremy

    2011-01-01

    As tumour irradiation modalities differ from one pathology to another, and are even proper to each pathology (they depend on tumour nature, histology, size, location, and so on), but as therapeutic objectives remain unchanged (to deliver the prescribed dose to the target-volume with the highest possible precision while preserving as much as possible sane tissues as well as neighbouring organs at risk), this bibliographical study aims, on the one hand, at quantifying the dose variation generated by heterogeneous structures crossed by the electron beam, and on the other hand, at optimising the use of boluses during surface irradiations, notably in the case of skin cancers. The author addresses therapeutic indications of irradiation of skin cancers and of thoracic wall for which the application of a bolus is required, and then the associated irradiation techniques as well as bolus characteristics

  9. Onset and effectiveness of rocuronium for rapid onset of paralysis in patients with major burns: priming or large bolus

    Science.gov (United States)

    Han, T.-H.; Martyn, J. A. J.

    2009-01-01

    Background Burn injury leads to resistance to the effects of non-depolarizing muscle relaxants. We tested the hypothesis that a larger bolus dose is as effective as priming for rapid onset of paralysis after burns. Methods Ninety adults, aged 18–59 yr with 40 (2)% [mean (se)] burn and 30 (2) days after injury, received rocuronium as a priming dose followed by bolus (0.06+0.94 mg kg−1), or single bolus of either 1.0 or 1.5 mg kg−1. Sixty-one non-burned, receiving 1.0 mg kg−1 as a primed (0.06+0.94 mg kg−1) or full bolus dose, served as controls. Acceleromyography measured the onset times. Results Priming when compared with 1.0 mg kg−1 bolus in burned patients shortened the time to first appearance of twitch depression (30 vs 45 s, P<0.05) and time to maximum twitch inhibition (135 vs 210 s, P<0.05). The onset times between priming and higher bolus dose (1.5 mg kg−1) were not different (30 vs 30 s for first twitch depression and 135 vs 135 s for maximal depression, respectively). The onset times in controls, however, were significantly (P<0.05) faster than burns both for priming and for full bolus (15 and 15 s, respectively, for first twitch depression and 75 and 75 s for maximal depression). Priming caused respiratory distress in 10% of patients in both groups. Intubating conditions in burns were significantly better with 1.5 mg kg−1 than with priming or full 1.0 mg kg−1 bolus. Conclusions A dose of 1.5 mg kg−1 not only produces an initial onset of paralysis as early as 30 s, which we speculate could be a reasonable onset time for relief of laryngospasm, but also has an onset as fast as priming with superior intubating conditions and no respiratory side-effects. PMID:19029093

  10. Use of cornmeal bolus as an aid in obtaining cranial four-vessel angiograms.

    Science.gov (United States)

    Weathers, R M; Lee, A

    1975-01-01

    In cranial angiography it has always been difficult to visualize extracranial vessels of the cervico-thoracic region, upon one radiograph, by using the same exposure factors for both regions. For this reason, we experimented and found that by applying a dry cornmeal bolus on specific areas of the neck a technically superior radiograph of these regions can be achieved. This bolus simulated added soft tissue to the cervical region. The density of the cervical region is now similar to that of the upper thoracic. As a result, factors set for one exposure will adequately penetrate both areas.

  11. Evaluation of the Eclipse eMC algorithm for bolus electron conformal therapy using a standard verification dataset.

    Science.gov (United States)

    Carver, Robert L; Sprunger, Conrad P; Hogstrom, Kenneth R; Popple, Richard A; Antolak, John A

    2016-05-08

    The purpose of this study was to evaluate the accuracy and calculation speed of electron dose distributions calculated by the Eclipse electron Monte Carlo (eMC) algorithm for use with bolus electron conformal therapy (ECT). The recent com-mercial availability of bolus ECT technology requires further validation of the eMC dose calculation algorithm. eMC-calculated electron dose distributions for bolus ECT have been compared to previously measured TLD-dose points throughout patient-based cylindrical phantoms (retromolar trigone and nose), whose axial cross sections were based on the mid-PTV (planning treatment volume) CT anatomy. The phantoms consisted of SR4 muscle substitute, SR4 bone substitute, and air. The treatment plans were imported into the Eclipse treatment planning system, and electron dose distributions calculated using 1% and processors (Intel Xeon E5-2690, 2.9 GHz) on a framework agent server (FAS). In comparison, the eMC was significantly more accurate than the pencil beam algorithm (PBA). The eMC has comparable accuracy to the pencil beam redefinition algorithm (PBRA) used for bolus ECT planning and has acceptably low dose calculation times. The eMC accuracy decreased when smoothing was used in high-gradient dose regions. The eMC accuracy was consistent with that previously reported for accuracy of the eMC electron dose algorithm and shows that the algorithm is suitable for clinical implementation of bolus ECT.

  12. Electric vehicle propulsion alternatives

    Science.gov (United States)

    Secunde, R. R.; Schuh, R. M.; Beach, R. F.

    1983-01-01

    Propulsion technology development for electric vehicles is summarized. Analytical studies, technology evaluation, and the development of technology for motors, controllers, transmissions, and complete propulsion systems are included.

  13. Fuel Effective Photonic Propulsion

    Science.gov (United States)

    Rajalakshmi, N.; Srivarshini, S.

    2017-09-01

    With the entry of miniaturization in electronics and ultra-small light-weight materials, energy efficient propulsion techniques for space travel can soon be possible. We need to go for such high speeds so that the generation’s time long interstellar missions can be done in incredibly short time. Also renewable energy like sunlight, nuclear energy can be used for propulsion instead of fuel. These propulsion techniques are being worked on currently. The recently proposed photon propulsion concepts are reviewed, that utilize momentum of photons generated by sunlight or onboard photon generators, such as blackbody radiation or lasers, powered by nuclear or solar power. With the understanding of nuclear photonic propulsion, in this paper, a rough estimate of nuclear fuel required to achieve the escape velocity of Earth is done. An overview of the IKAROS space mission for interplanetary travel by JAXA, that was successful in demonstrating that photonic propulsion works and also generated additional solar power on board, is provided; which can be used as a case study. An extension of this idea for interstellar travel, termed as ‘Star Shot’, aims to send a nanocraft to an exoplanet in the nearest star system, which could be potentially habitable. A brief overview of the idea is presented.

  14. In-Space Propulsion Technology Program Solar Electric Propulsion Technologies

    Science.gov (United States)

    Dankanich, John W.

    2006-01-01

    NASA's In-space Propulsion (ISP) Technology Project is developing new propulsion technologies that can enable or enhance near and mid-term NASA science missions. The Solar Electric Propulsion (SEP) technology area has been investing in NASA s Evolutionary Xenon Thruster (NEXT), the High Voltage Hall Accelerator (HiVHAC), lightweight reliable feed systems, wear testing, and thruster modeling. These investments are specifically targeted to increase planetary science payload capability, expand the envelope of planetary science destinations, and significantly reduce the travel times, risk, and cost of NASA planetary science missions. Status and expected capabilities of the SEP technologies are reviewed in this presentation. The SEP technology area supports numerous mission studies and architecture analyses to determine which investments will give the greatest benefit to science missions. Both the NEXT and HiVHAC thrusters have modified their nominal throttle tables to better utilize diminished solar array power on outbound missions. A new life extension mechanism has been implemented on HiVHAC to increase the throughput capability on low-power systems to meet the needs of cost-capped missions. Lower complexity, more reliable feed system components common to all electric propulsion (EP) systems are being developed. ISP has also leveraged commercial investments to further validate new ion and hall thruster technologies and to potentially lower EP mission costs.

  15. Modeling of Ship Propulsion Performance

    DEFF Research Database (Denmark)

    Pedersen, Benjamin Pjedsted; Larsen, Jan

    2009-01-01

    Full scale measurements of the propulsion power, ship speed, wind speed and direction, sea and air temperature, from four different loading conditions has been used to train a neural network for prediction of propulsion power. The network was able to predict the propulsion power with accuracy...

  16. Disfunção temporária do nervo lingual após uso de máscara laríngea: relato de caso Disfunción temporal del nervio lingual trás del uso de máscara laríngea: relato de caso Temporary lingual nerve dysfunction following the use of the laryngeal mask airway: report

    Directory of Open Access Journals (Sweden)

    Hugo Eckener Dantas de Pereira Cardoso

    2007-08-01

    Full Text Available JUSTIFICATIVA E OBJETIVOS: A máscara laríngea tem sido utilizada com freqüência em Anestesiologia. O emprego dessa técnica, embora esteja relacionado com um menor número de complicações quando comparado com a cânula traqueal, não é isento de morbidade, principalmente, nos casos de via aérea difícil. O objetivo desse relato foi apresentar um caso de lesão unilateral de nervo lingual após o uso da máscara laríngea. RELATO DO CASO: Paciente do sexo feminino foi submetida à intervenção cirúrgica para troca de prótese mamária bilateral, sob anestesia geral balanceada, com máscara laríngea de tamanho 3. O volume aplicado para insuflação do balonete foi de 30 mL de ar. Após a primeira hora do pós-operatório, iniciou quadro de dormência e dor na garganta e nos dois terços posteriores da língua que evoluiu em 24 horas com perda da percepção do sabor dos alimentos. A suspeita diagnóstica foi de neuropraxia do nervo lingual pelo uso de máscara laríngea. Esse quadro se manteve por três semanas, período em que se obteve resolução dos sintomas. CONCLUSÃO: Complicações após o uso de máscara laríngea, apesar de raras, podem ocorrer. A neuropraxia do nervo lingual é uma delas. O seu diagnóstico é clínico, e a sua evolução, favorável, com resolução dos sintomas em semanas ou meses.JUSTIFICATIVA Y OBJETIVOS: La máscara laríngea ha sido utilizada con frecuencia en Anestesiología. El empleo de esa técnica, aunque esté relacionada a un menor número de complicaciones cuando se le compara a la cánula traqueal, no está exento de morbidez, principalmente en los casos de vía aérea difícil. El objetivo de este relato fue presentar un caso de lesión unilateral de nervio lingual trás del uso de la máscara laríngea. RELATO DEL CASO: Paciente del sexo femenino, sometida a intervención quirúrgica para cambio de prótesis mamaria bilateral, bajo anestesia general balanceada, con máscara laríngea de tama

  17. Serum levels of bupivacaine after pre-peritoneal bolus vs. epidural bolus injection for analgesia in abdominal surgery: A safety study within a randomized controlled trial

    NARCIS (Netherlands)

    Mungroop, Timothy H.; van Samkar, Ganapathy; Geerts, Bart F.; van Dieren, Susan; Besselink, Marc G.; Veelo, Denise P.; Lirk, Philipp

    2017-01-01

    Continuous wound infiltration (CWI) has become increasingly popular in recent years as an alternative to epidural analgesia. As catheters are not placed until the end of surgery, more intraoperative opioid analgesics might be needed. We, therefore, added a single pre-peritoneal bolus of bupivacaine

  18. Developing Bi-Lingual Skills for Translation through an Online Multimedia-Supported Learning Environment

    Science.gov (United States)

    Eser, Oktay; Saltan, Fatih; Ersanli, Ceylan Yangin; Erdem, Gamze

    2016-01-01

    Recent research shows that bi-lingual competence is one of the necessary skills that a translator needs in order to translate (PACTE, 2003). Apart from the mother tongue, a translator must have a command of other working languages. The purpose of this study was to investigate whether the online multimedia-supported learning environment concerning…

  19. Post-mastectomy radiation therapy without usage of a bolus may be a reasonable option

    International Nuclear Information System (INIS)

    Nakamura, Naoki; Arahira, Satoko; Zenda, Sadamoto; Yoneyama, Kimiyasu; Mukai, Hirofumi; Onozawa, Masakatsu; Toshima, Masamichi; Motegi, Atsushi; Hirano, Yasuhiro; Hojo, Hidehiro; Kibe, Yuichi; Akimoto, Tetsuo

    2017-01-01

    To clarify the efficacy and toxicity of post-mastectomy radiation therapy (PMRT) without usage of a bolus, we identified 129 consecutive patients who received PMRT at the National Cancer Center Hospital East between 2003 and 2012. Seven of the 129 patients who received breast reconstruction before PMRT were excluded. All patients received PMRT of 6 MV photons, without usage of a bolus. The median follow-up duration for all eligible patients was 47.7 months (range: 4.0–123.2). Local, locoregional and isolated locoregional recurrence was found in 12 (9.8%), 14 (11%) and 5 patients (4.1%), respectively. The 3- and 5-year cumulative incidence of local recurrence, locoregional recurrence and isolated locoregional recurrence was 9.2 and 10.7%, 10.8 and 12.4%, and 4.3 and 4.3%, respectively. Although Grade 2 dermatitis was found in 11 patients (9.0%), no Grade 3–4 dermatitis was found. On univariate analysis, only a non-luminal subtype was a significant predictor for local recurrence (P < 0.001). On multivariate analysis, a non-luminal subtype remained as an independent predictor for local recurrence (P = 0.003, odds ratio: 10.9, 95% confidence interval: 2.23–53.1). In conclusion, PMRT without usage of a bolus resulted in a low rate of severe acute dermatitis without an apparent increase in local recurrence. PMRT without usage of a bolus may be reasonable, especially for patients with a luminal subtype.

  20. The velocity of a radioactive bolus in the oesophagus evaluated by means of an image segmentation algorithm

    International Nuclear Information System (INIS)

    Miquelin, Charlie A; Dantas, Roberto O; Oliveira, Ricardo B; Braga, Francisco Jos H. N

    2002-01-01

    Classical scintigraphic evaluation of a radioactive bolus through the oesophagus is based on regions of interest and time/activity curves, which only gives information about the total time required for it to cross the organ. Instantaneous parameters can be obtained if the exact position (centroid) of the bolus is known. For that, one needs to know the co-ordinates of the centre of mass of the bolus radioactivity distribution. From this, one can obtain velocity at each time. Obtaining such a new parameter would be important, to try to determine whether the anatomical differences among the 3 thirds of the oesophagus have a functional correspondence or not. We have studied 5 normal volunteers (4 males, 1 female, 33-68 yo). Each volunteer swallowed (unique swallowing) 40 MBq of 99mTc-phytate in 10 ml water. Eighty frames (0.3 sec) were acquired in a scintillation camera. External marks were used to separate the pharynx from the oesophagus. Images were transformed into bitmap by means of a Sophy Medical processing module and analysed by means of the algorithm, which determines the co-ordinates of the centroid (horizontal and vertical) for each frame and instant velocities through the organ. Different velocities were found in typical evaluations. Curves representing the different positions of the bolus C and the correspondent different Vs were obtained. Different velocities of the bolus were detected during the pharyngeal phase, and proximal, mid and distal parts of the oesophagus. Larger studies are necessary, but it seems that the velocity of a radioactive bolus changes in the different parts of the oesophagus. It is reasonable to say that there is a functional correspondence to the anatomical differences in the organ (Au)

  1. Control of anterior segment using an antero-posterior lingual sliding retraction system: a preliminary cone-beam CT study

    Directory of Open Access Journals (Sweden)

    Min Hwang

    2018-01-01

    Full Text Available Abstract Background This study was performed to evaluate the treatment effects of the antero-posterior lingual retractor (APLR, focusing on the 3-dimensional (3D tooth movement of the maxillary anterior teeth and their alveolar bone levels. Methods En masse retraction was performed using either the C-lingual retractor (CLR, C-group, n = 9 or the antero-posterior lingual retractor (APLR, AP-group, n = 8. We evaluated 3D movement of the maxillary anterior teeth and alveolar bone levels, root length of the central incisors, long axes of the maxillary canines, and occlusal plane changes from CBCT images. Results After retraction, the central incisors were more significantly intruded and their root apex was more retracted in the AP-group. The long axis of the canine was well maintained in the AP-group. There were no differences in the steepness of occlusal plane and the incidence of alveolar bone loss or of root resorption during en masse retraction with the two retractors. Conclusions The clockwise bowing effect of the anterior segment was less with the APLR, which prevented unwanted canine movement.

  2. WE-F-16A-05: Use of 3D-Printers to Create a Tissue Equivalent 3D-Bolus for External Beam Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Burleson, S; Baker, J; Hsia, A; Xu, Z [Stony Brook Medicine, Stony Brook, NY (United States)

    2014-06-15

    Purpose: The purpose of this project is to demonstrate that a non-expensive 3D-printer can be used to manufacture a 3D-bolus for external beam therapy. The printed bolus then can be modeled in our treatment planning system to ensure accurate dose delivery to the patient. Methods: We developed a simple method to manufacture a patient-specific custom 3Dbolus. The bolus is designed using Eclipse Treatment Planning System, contoured onto the patients CT images. The bolus file is exported from Eclipse to 3D-printer software, and then printed using a 3D printer. Various tests were completed to determine the properties of the printing material. Percent depth dose curves in this material were measured with electron and photon beams for comparison to other materials. In order to test the validity of the 3D printed bolus for treatment planning, a custom bolus was printed and tested on the Rando phantom using film for a dose plane comparison. We compared the dose plane measured on the film to the same dose plane exported from our treatment planning system using Film QA software. The gamma-dose distribution tool was used in our film analysis. Results: We compared point measurements throughout the dose plane and were able to achieve greater than 95% passing rate at 3% dose difference and 3 mm distance to agreement, which is our departments acceptable gamma pixel parameters. Conclusion: The printed 3D bolus has proven to be accurately modeled in our treatment planning system, it is more conformal to the patient surface and more durable than other bolus currently used (wax, superflab etc.). It is also more convenient and less costly than comparable bolus from milling machine companies.

  3. WE-F-16A-05: Use of 3D-Printers to Create a Tissue Equivalent 3D-Bolus for External Beam Therapy

    International Nuclear Information System (INIS)

    Burleson, S; Baker, J; Hsia, A; Xu, Z

    2014-01-01

    Purpose: The purpose of this project is to demonstrate that a non-expensive 3D-printer can be used to manufacture a 3D-bolus for external beam therapy. The printed bolus then can be modeled in our treatment planning system to ensure accurate dose delivery to the patient. Methods: We developed a simple method to manufacture a patient-specific custom 3Dbolus. The bolus is designed using Eclipse Treatment Planning System, contoured onto the patients CT images. The bolus file is exported from Eclipse to 3D-printer software, and then printed using a 3D printer. Various tests were completed to determine the properties of the printing material. Percent depth dose curves in this material were measured with electron and photon beams for comparison to other materials. In order to test the validity of the 3D printed bolus for treatment planning, a custom bolus was printed and tested on the Rando phantom using film for a dose plane comparison. We compared the dose plane measured on the film to the same dose plane exported from our treatment planning system using Film QA software. The gamma-dose distribution tool was used in our film analysis. Results: We compared point measurements throughout the dose plane and were able to achieve greater than 95% passing rate at 3% dose difference and 3 mm distance to agreement, which is our departments acceptable gamma pixel parameters. Conclusion: The printed 3D bolus has proven to be accurately modeled in our treatment planning system, it is more conformal to the patient surface and more durable than other bolus currently used (wax, superflab etc.). It is also more convenient and less costly than comparable bolus from milling machine companies

  4. Lingual thyroid: value of integrated imaging

    Energy Technology Data Exchange (ETDEWEB)

    Giovagnorio, F. [Sezione di Radiologia e Diagnostica per Immagini, Dipt. di Medicina Sperimentale e Patologia, Univ. `La Sapienza`, Rome (Italy); Cordier, A. [Ist. di Clinica Otorinolaringoiatrica, Univ. `La Sapienza`, Rome (Italy); Romeo, R. [Ist. di Clinica Otorinolaringoiatrica, Univ. `La Sapienza`, Rome (Italy)

    1996-02-01

    Lingual thyroid is an uncommon cause of oropharyngeal mass, due to a congential anomaly of thyroidal development and migration: It is defined precisely as the presence of thyroid tissue in the midline of the tongue base between circumvallatae papilae and the epiglottis. We report a case of lignual thyroid in which the integration of clinical data, sonography, color-duplex Doppler, MRI and scintigraphy was determinant in demonstrating the disease. A 22-year-old woman presented with a sensation of foreign body in the throat, dysphonia, dyspnoea and dysphagia; we performed sonography (7.5 MHz linear probe), color Doppler (7 MHz Doppler frequeny, PRF 3500 Hz) and MRI (1.5 T, spin-echo T1- and T2-weighted images with administration of Gd-DTPA); a scan with {sup 123}I demonstrated a relevant uptake at the base of the tongue, but no uptake at the typical thyroid location. The gland was removed and partially transplanted in the strap muscles of the neck. (orig.)

  5. Lingual thyroid: value of integrated imaging

    International Nuclear Information System (INIS)

    Giovagnorio, F.; Cordier, A.; Romeo, R.

    1996-01-01

    Lingual thyroid is an uncommon cause of oropharyngeal mass, due to a congential anomaly of thyroidal development and migration: It is defined precisely as the presence of thyroid tissue in the midline of the tongue base between circumvallatae papilae and the epiglottis. We report a case of lignual thyroid in which the integration of clinical data, sonography, color-duplex Doppler, MRI and scintigraphy was determinant in demonstrating the disease. A 22-year-old woman presented with a sensation of foreign body in the throat, dysphonia, dyspnoea and dysphagia; we performed sonography (7.5 MHz linear probe), color Doppler (7 MHz Doppler frequeny, PRF 3500 Hz) and MRI (1.5 T, spin-echo T1- and T2-weighted images with administration of Gd-DTPA); a scan with 123 I demonstrated a relevant uptake at the base of the tongue, but no uptake at the typical thyroid location. The gland was removed and partially transplanted in the strap muscles of the neck. (orig.)

  6. Cardiac T1 mapping in congenital heart disease: bolus vs. infusion protocols for measurements of myocardial extracellular volume fraction.

    Science.gov (United States)

    Al-Wakeel-Marquard, Nadya; Rastin, Sanaz; Muench, Frédéric; O H-Ici, Darach; Yilmaz, Sevim; Berger, Felix; Kuehne, Titus; Messroghli, Daniel R

    2017-12-01

    Myocardial extracellular volume fraction (ECV) reflecting diffuse myocardial fibrosis can be measured with T1 mapping cardiovascular magnetic resonance (CMR) before and after the application of a gadolinium-based extracellular contrast agent. The equilibrium between blood and myocardium contrast concentration required for ECV measurements can be obtained with a primed contrast infusion (equilibrium contrast-CMR). We hypothesized that equilibrium can also be achieved with a single contrast bolus to accurately measure diffuse myocardial fibrosis in patients with congenital heart disease (CHD). Healthy controls (n = 17; median age 24.0 years) and patients with CHD (n = 19; 25.0 years) were prospectively enrolled. Using modified Look-Locker inversion recovery T1 mapping before, 15 min after bolus injection, and during constant infusion of gadolinium-DOTA, T1 values were obtained for blood pool and myocardium of the left ventricle (LV), the interventricular septum (IVS), and the right ventricle (RV) in a single midventricular plane in short axis or in transverse orientation. ECV of LV, IVS and RV by bolus-only and bolus-infusion correlated significantly in CHD patients (r = 0.94, 0.95, and 0.74; p < 0.01, respectively) and healthy controls (r = 0.96, 0.89, and 0.64; p < 0.05, respectively). Bland-Altman plots revealed no significant bias between the techniques for any of the analyzed regions. ECV of LV and RV myocardium measured by bolus-only T1 mapping agrees well with bolus-infusion measurements in patients with CHD. The use of a bolus-only approach facilitates the integration of ECV measurements into existing CMR imaging protocols, allowing for assessment of diffuse myocardial fibrosis in CHD in clinical routine.

  7. Care-bolus tracking systems in multislice-helical computed tomography - a new method in the screening of cardiovascular failure?

    International Nuclear Information System (INIS)

    Stueckle, C.A.; Kickuth, R.; Kirchner, E.M.; Liermann, D.; Kirchner, J.

    2002-01-01

    Purpose. Recently bolus tracking systems were developed to improve the timing of intravenous contrast media application in helical computed tomography. We investigated the benefit of this new method as a parameter of the cardiac function.Material and methods. Retrospective analysis of 64 patients which incidentally underwent bolus triggered contrast enhanced helical CT and invasive investigation of the heart within one week. All examinations were performed on the CT scanner Somatom Plus 4 Volume Zoom (Siemens Corp., Forchheim, Germany) using the C.A.R.E. trademark Bolus software. This performs repetitive low- dose test scans (e.g. for the abdomen: 140 kV, 20 mA, TI 0,5 s) and measures the Hounsfield attenuation (increase over the baseline) in a preselected region of interest. The displayed increase of vascular density over the time after peripheral contrast media injection (75 ml Iopromid (300 mg/ml), 2 ml/s) was categorised to three types: (a) rapid increase, (b) deceleration before a 100 HE threshold was reached and (c) one or more peaks. The findings of the invasive investigation of the heart were correlated to the findings of the bolus-tracking measurements.Results. The examinations were categorized as follows: 19 type A, 34 type B, 11 type C. We found a high significant correlation between the type of the Hounsfield attenuation and systolic pressure in the left ventricle. There was no correlation between the type of the Hounsfield attenuation and the diastolic pressure in the left ventricle, the pressures related to the right ventricle or the ejection fraction. The bolus- tacking system showed a sensitivity of 53, a specificity of 82, an accuracy of 70%, a positive predictive value of 70% and a negative predictive value of 70% in detection of left heart failure.Conclusion. The bolus tracking system C.A.R.E.-bolus copyright often shows atypical Hounsfield attenuation in cases of cardiac failure but is not suitable as a screening method of the cardiopulmonary

  8. Wheelchairs propulsion analysis: review

    Directory of Open Access Journals (Sweden)

    Yoshimasa Sagawa Júnior

    Full Text Available OBJECTIVES: To analyze aspects related with wheelchair propulsion. MATERIALS AND METHODS: In order to delineate this review the search for information was carried out within electronics databases, using the following descriptors: "wheelchair propulsion", "wheelchair biomechanics" e "wheelchair users". Full papers published in English and French were included in the study. RESULTS: The wheelchair propulsion is a complex movement that requires the execution of repeated bi manual forces applications during a short time period. In this movement high levels of force must be produced due to the bad mechanical performance of the wheelchair. Could be characterized that wheelchair users are not satisfied with their wheelchair, the places are not adapted to their presence and lack of specific criteria for the adjustment of this equipment. The main points to look at are the seat height in relation to elbow flexion (100-120 degrees with his hand in the propulsion rim and tire pressure. The semicircular mode of technique propulsion seems to be more appropriate; in this pattern the wheelchair user returns his hand under the rim after propulsion. Efforts in wheelchairs are high and the incidence of injuries in wheelchair users is high. CONCLUSION: One can conclude that in spite of researchers’ efforts there are still many divergences between topics and methods of evaluation, what makes difficult to apply the experimental results to the wheelchairs users’ daily life.

  9. Ion Beam Propulsion Study

    Science.gov (United States)

    2008-01-01

    The Ion Beam Propulsion Study was a joint high-level study between the Applied Physics Laboratory operated by NASA and ASRC Aerospace at Kennedy Space Center, Florida, and Berkeley Scientific, Berkeley, California. The results were promising and suggested that work should continue if future funding becomes available. The application of ion thrusters for spacecraft propulsion is limited to quite modest ion sources with similarly modest ion beam parameters because of the mass penalty associated with the ion source and its power supply system. Also, the ion source technology has not been able to provide very high-power ion beams. Small ion beam propulsion systems were used with considerable success. Ion propulsion systems brought into practice use an onboard ion source to form an energetic ion beam, typically Xe+ ions, as the propellant. Such systems were used for steering and correction of telecommunication satellites and as the main thruster for the Deep Space 1 demonstration mission. In recent years, "giant" ion sources were developed for the controlled-fusion research effort worldwide, with beam parameters many orders of magnitude greater than the tiny ones of conventional space thruster application. The advent of such huge ion beam sources and the need for advanced propulsion systems for exploration of the solar system suggest a fresh look at ion beam propulsion, now with the giant fusion sources in mind.

  10. Anxiety can significantly explain bolus perception in the context of hypotensive esophageal motility: Results of a large multicenter study in asymptomatic individuals.

    Science.gov (United States)

    Cisternas, D; Scheerens, C; Omari, T; Monrroy, H; Hani, A; Leguizamo, A; Bilder, C; Ditaranto, A; Ruiz de León, A; Pérez de la Serna, J; Valdovinos, M A; Coello, R; Abrahao, L; Remes-Troche, J; Meixueiro, A; Zavala, M A; Marin, I; Serra, J

    2017-09-01

    Previous studies have not been able to correlate manometry findings with bolus perception. The aim of this study was to evaluate correlation of different variables, including traditional manometric variables (at diagnostic and extreme thresholds), esophageal shortening, bolus transit, automated impedance manometry (AIM) metrics and mood with bolus passage perception in a large cohort of asymptomatic individuals. High resolution manometry (HRM) was performed in healthy individuals from nine centers. Perception was evaluated using a 5-point Likert scale. Anxiety was evaluated using Hospitalized Anxiety and Depression scale (HAD). Subgroup analysis was also performed classifying studies into normal, hypotensive, vigorous, and obstructive patterns. One hundred fifteen studies were analyzed (69 using HRM and 46 using high resolution impedance manometry (HRIM); 3.5% swallows in 9.6% of volunteers were perceived. There was no correlation of any of the traditional HRM variables, esophageal shortening, AIM metrics nor bolus transit with perception scores. There was no HRM variable showing difference in perception when comparing normal vs extreme values (percentile 1 or 99). Anxiety but not depression was correlated with perception. Among hypotensive pattern, anxiety was a strong predictor of variance in perception (R 2 up to .70). Bolus perception is less common than abnormal motility among healthy individuals. Neither esophageal motor function nor bolus dynamics evaluated with several techniques seems to explain differences in bolus perception. Different mechanisms seem to be relevant in different manometric patterns. Anxiety is a significant predictor of bolus perception in the context of hypotensive motility. © 2017 John Wiley & Sons Ltd.

  11. Evaluation of the esophagus with a marshmallow bolus: clarifying the cause of dysphagia.

    Science.gov (United States)

    Ott, D J; Kelley, T F; Chen, M Y; Gelfand, D W

    1991-01-01

    We reviewed the radiographic examinations of the esophagus and medical records in 117 patients (55 women and 62 men; mean age, 52 years) in which a marshmallow bolus was also given. A one-third to one-half piece of a standard marshmallow was used with a mean size of 23 mm (+/- 4.5 mm SD) measured in vivo. In 62 patients with no intrinsic structural narrowing of the esophagus, impaction occurred in only seven (11%). Four of these patients had an esophageal motility disorder, and three had a previous Nissen fundoplication. The remaining 55 patients had lower esophageal mucosal rings (47) or peptic strictures (8). Marshmallow impaction was seen in 27 of 47 rings (57%) and was inversely related to ring size, and in six of eight strictures (75%). Also, impaction was related to the ratio of bolus size to ring caliber, and invariably occurred when this ratio was greater than 1.5. Dysphagia was the presenting complaint in 76 (65%) patients, but was found equally in those without intrinsic narrowing and in those with ring or stricture. However, dysphagia was reproduced by the marshmallow bolus only in patients with esophageal narrowing or abnormal motility.

  12. Replacement of oxytocin bolus administration by infusion: influences on postpartum outcome.

    Science.gov (United States)

    Löytved-Hardegg, Julia J; Brunner, Mirjam; Ries, Jean-Jacques; von Felten, Stefanie; Heugel, Christina; Lapaire, Olav; Voekt, Cora; Hösli, Irene

    2016-06-01

    Postpartum haemorrhage (PPH) represents a leading cause of maternal morbidity and mortality. Giving oxytocin after birth reduces the risk for PPH. It has never been tested whether different methods of oxytocin administration affect the maternal outcome. This study aims to compare the infusion versus the bolus application of oxytocin after singleton vaginal delivery. This retrospective monocentre study compares the incidence of clinically relevant postpartum complications in women receiving 5 IE of oxytocin as a bolus or as a 100 ml-infusion over 5 min, given immediately after birth. Included were women delivering singletons vaginally at term. We used propensity score weighting to compare outcomes between women receiving bolus and infusion and to minimize the selection bias in this retrospective cohort. 1765 patients were included. Patient characteristics were balanced. We found no significant differences for the combined overall postpartum adverse outcome (the incidence of PPH, manual removal of the placenta and/or curettage). For the single outcomes, we observed a significantly higher frequency of manual removal of the placenta (Odds ratio 1.47, 95 % CI 1.02-2.13) and a slightly higher but clinically not relevant estimated blood loss (Relative effect 1.05, 95 % CI 1.01-1.10) in the infusion group. The data show a tendency towards more complications in the infusion group. It is related to a more frequent need for manual removal of the placenta.

  13. Alternative propulsion for automobiles

    CERN Document Server

    Stan, Cornel

    2017-01-01

    The book presents – based on the most recent research and development results worldwide - the perspectives of new propulsion concepts such as electric cars with batteries and fuel cells, and furthermore plug in hybrids with conventional and alternative fuels. The propulsion concepts are evaluated based on specific power, torque characteristic, acceleration behaviour, specific fuel consumption and pollutant emissions. The alternative fuels are discussed in terms of availability, production, technical complexity of the storage on board, costs, safety and infrastructure. The book presents summarized data about vehicles with electric and hybrid propulsion. The propulsion of future cars will be marked by diversity – from compact electric city cars and range extender vehicles for suburban and rural areas up to hybrid or plug in SUV´s, Pick up´s and luxury class automobiles.

  14. Morphology of the Lingual Papillae in the Least Weasel (Mustela nivalis)

    OpenAIRE

    El Bakary, Neveen E. R; Emura, Shoichi

    2016-01-01

    The dorsal surface structure of the lingual papillae in the least weasel was compared with that of other carnivorous mammalian species. Two types of mechanical papillae (filiform and conical) and two types of gustatory papillae (fungiform and vallate) were observed. The filiform papillae had secondary processes. Rarely conical papillae were observed. A few taste buds were seen on the surfaces of the fungiform papillae. The four vallate papillae were located on both sides of the posterior end ...

  15. Cross-lingual and cross-domain discourse segmentation of entire documents

    DEFF Research Database (Denmark)

    Braud, Chloé; Lacroix, Ophélie; Søgaard, Anders

    2017-01-01

    -quality syntactic parses and rich heuristics that are not generally available across languages and domains. In this paper, we propose statistical discourse segmenters for five languages and three domains that do not rely on gold pre-annotations. We also consider the problem of learning discourse segmenters when...... no labeled data is available for a language. Our fully supervised system obtains 89.5% F1 for English newswire, with slight drops in performance on other domains, and we report supervised and unsupervised (cross-lingual) results for five languages in total....

  16. Space transportation propulsion USSR launcher technology, 1990

    Science.gov (United States)

    1991-01-01

    Space transportation propulsion U.S.S.R. launcher technology is discussed. The following subject areas are covered: Energia background (launch vehicle summary, Soviet launcher family) and Energia propulsion characteristics (booster propulsion, core propulsion, and growth capability).

  17. Lingual Pressure as a Clinical Indicator of Swallowing Function in Parkinson's Disease

    Science.gov (United States)

    Pitts, Laura L.; Morales, Sarah; Stierwalt, Julie A. G.

    2018-01-01

    Purpose: Swallowing impairment, or dysphagia, is a known contributor to reduced quality of life, pneumonia, and mortality in Parkinson's disease (PD). However, the contribution of tongue dysfunction, specifically inadequate pressure generation, to dysphagia in PD remains unclear. Our purpose was to determine whether lingual pressures in PD are (a)…

  18. Continuous indomethacin infusion may be less effective than bolus infusions for ductal closure in very low birth weight infants

    NARCIS (Netherlands)

    de Vries, NKS; Jagroep, FK; Jaarsma, AS; Elzenga, NJ; Bos, AF

    The effectiveness of continuous indomethacin (INDO) infusion versus bolus infusions for closure of patent ductus arteriosus (PDA) was investigated. The study design was an open-label case series (continuous INDO) with historic controls matched for gestational age (bolus INDO). Ductal closure rates

  19. Reactors for nuclear electric propulsion

    Energy Technology Data Exchange (ETDEWEB)

    Buden, D.; Angelo, J.A. Jr.

    1981-01-01

    Propulsion is the key to space exploitation and power is the key to propulsion. This paper examines the role of nuclear fission reactors as the primary power source for high specific impulse electric propulsion systems for space missions of the 1980s and 1990s. Particular mission applications include transfer to and a reusable orbital transfer vehicle from low-Earth orbit to geosynchronous orbit, outer planet exploration and reconnaissance missions, and as a versatile space tug supporting lunar resource development. Nuclear electric propulsion is examined as an indispensable component in space activities of the next two decades.

  20. Reactors for nuclear electric propulsion

    International Nuclear Information System (INIS)

    Buden, D.; Angelo, J.A. Jr.

    1981-01-01

    Propulsion is the key to space exploitation and power is the key to propulsion. This paper examines the role of nuclear fission reactors as the primary power source for high specific impulse electric propulsion systems for space missions of the 1980s and 1990s. Particular mission applications include transfer to and a reusable orbital transfer vehicle from low-Earth orbit to geosynchronous orbit, outer planet exploration and reconnaissance missions, and as a versatile space tug supporting lunar resource development. Nuclear electric propulsion is examined as an indispensable component in space activities of the next two decades

  1. Implementation of a split-bolus single-pass CT protocol at a UK major trauma centre to reduce excess radiation dose in trauma pan-CT

    International Nuclear Information System (INIS)

    Leung, V.; Sastry, A.; Woo, T.D.; Jones, H.R.

    2015-01-01

    Aim: To quantify the dose reduction and ensure that the use of a split-bolus protocol provided sufficient vascular enhancement. Materials and methods: Between 1 January 2014 and 31 May 2014, both split bolus and traditional two-phase scans were performed on a single CT scanner (SOMATOM Definition AS+, Siemens Healthcare) using a two-pump injector (Medrad Stellant). Both protocols used Siemens' proprietary tube current and tube voltage modulation techniques (CARE dose and CARE kV). The protocols were compared retrospectively to assess the dose–length product (DLP), aortic radiodensity at the level of the coeliac axis and radiodensity of the portal vein. Results: There were 151 trauma CT examinations during this period. Seventy-eight used the split-bolus protocol. Seventy-one had traditional two-phase imaging. One patient was excluded as they were under the age of 18 years. The radiodensity measurements for the portal vein were significantly higher (p<0.001) in the split-bolus protocol. The mean aortic enhancement in both protocols exceeded 250 HU, although the traditional two-phase protocol gave greater arterial enhancement (p<0.001) than the split-bolus protocol. The split-bolus protocol had a significantly lower (p<0.001) DLP with 43.5% reduction in the mean DLP compared to the traditional protocol. Conclusion: Split-bolus CT imaging offers significant dose reduction for this relatively young population while retaining both arterial and venous enhancement. -- Highlights: •We implemented a split bolus pan-CT protocol for trauma CT. •We compared the radiation dose and vascular enhancement of the split bolus protocol to a traditional two phase protocol. •The split bolus protocol had a 43.5% reduction in mean DLP

  2. Comparison of Bolus Phenylephrine, Ephedrine and Mephentermine for Maintenance of Arterial Pressure during Spinal Anesth

    Directory of Open Access Journals (Sweden)

    B Bhattarai

    2010-03-01

    Full Text Available INTRODUCTION: Hypotension is common following spinal anesthesia. Various vasopressors have been indicated to prevent it. The study compares three such agents namely phenylephrine, ephedrine and mephentermine. METHODS: The study included 90 patients undergoing elective and emergency cesarean section who developed hypotension following subarachnoid blockade. Parturient were randomly divided into three groups each group had 30 patients. Group P received bolus of Phenylephrine 25 microgram, where as group E received Ephedrine 5mg and Group M received Mephentermine 6mg. RESULTS: It was found that rise of blood pressure was significantly higher in case of phenylephrine group in first six minutes, after the bolus, there was significant reduction in the heart rate in phenylephrine group, but there was tachycardia following administration of bolus ephedrine and mephenteramine. Neonatal APGAR score were similar in all three groups. CONCLUSIONS: All three drugs maintained hemodynamics within 20 percent of the baseline values on intravenous administration. Keywords: APGAR, ephedrine, hypotension, mephentermine, phenylephrine, spinal anesthesia.

  3. "The relationship between pharmacokinetic variables and pharmacodynamic profiles of bolus versus continuous infusion of furosemide in critically ill patients"

    Directory of Open Access Journals (Sweden)

    "Mojtaba Mojtahedzadeh

    2005-05-01

    Full Text Available In this investigation, the pharmacokinetic variables of continuous infusion and intermittent bolus injection of furosemide and the possible relationship between its pharmacokinetic characteristics and pharmacodynamic profile among intensive care unit (ICU patients were studied. In this prospective, randomized, clinical trial, twelve patients received IV bolus of 20 mg of the drug during 3 hours period and, the drug dose was doubled, when the urine output was less than 1 ml/kg/h (group 1. The other nine patients received a continuous intravenous furosemide infusion at the rate of 0.1 mg/kg/h (group 2. The amount of furosemide in serum was measured by high performance liquid chromatography (HPLC. Results showed a positive correlation between plasma clearance of furosemide and its diuretic activity (P=0.01. The pharmacokinetic parameters such as Vd (l, CL (ml/min, Ke (min-1 and t½ (min in continuous infusion patients were not significantly differed from the bolus patients (P-values 0.5, 0.9, 0.9,0.9, respectively. Nevertheless the observed plasma clearance of drug in the continuous infusion group was clinically higher than bolus injection group and as a result the cumulative urine output per hour per mg of furosemide in a continuous infusion was observed to be higher than bolus(P=0.2. Changes in serum sodium and potassium were similar for both groups, but bolus injection patients were associated with higher potassium depletion (P=0.001. Therefore, continuous infusion seems to be better means of diuretic therapy in critically ill patients.

  4. Rapid Bolus Administration Does not Increase The Extravasation Rate of Albumin: A Randomized Controlled Trial in The Endotoxemic Pig.

    Science.gov (United States)

    von Seth, Magnus; Lipcsey, Miklós; Engström, Peter; Larsson, Anders; Hillered, Lars; Maripuu, Enn; Widström, Charles; Sjölin, Jan

    2017-04-01

    Some experimental data suggest that rapid bolus administration of albumin causes less plasma-expanding effects than slow, continuous infusion. To determine whether rapid bolus administration, in comparison with slow infusion, results in greater extravasation of albumin in experimental septic shock we performed a randomized controlled trial with 32 endotoxemic pigs. The animals were monitored and ventilated with standard intensive care equipment and given 10 mL × kg 5% albumin labeled with Technetium-99m, either as a rapid 15-min bolus (Bolus group, n = 16) or as a 2-h infusion (Infusion group, n = 16). Radioactivity was monitored in plasma, extracellular microdialysate, and urine for 6 h. Physiological parameters were monitored hourly. Radioactivity in the liver, spleen, kidney, and lung was analyzed post mortem.The plasma area under the curve activity0-6 h was 4.4 ± 0.9 × 10 in the Bolus group and 4.4 ± 1.1 × 10 counts × min × mL × h in the Infusion group. Blood hemoglobin levels increased in both groups, suggesting severe capillary leakage. Yet, there were no group differences in albumin radioactivity in plasma, muscle tissue, urine, or in the post-mortem analysis of the organs. Following albumin administration, circulatory and respiratory parameters were similar in the two groups.In conclusion, the present results suggest that albumin might be given as a bolus without leading to increased extravasation of albumin, in contrast to previous animal experiments in rodents.

  5. Diagnostic evaluation of a case of lingual thyroid ectopia

    Directory of Open Access Journals (Sweden)

    Valeria Fiaschetti

    2016-09-01

    Full Text Available Thyroid ectopia can occur when the process of thyroid embryogenesis fails. Here, we present the case of a 30-year-old woman with thyroid ectopia that was discovered during magnetic resonance imaging of cervical spine for referred neck pain. Imaging revealed the presence of an encapsulated mass at the base of her tongue. The patient was not symptomatic for any compression of the airways. Diagnosis of ectopic lingual thyroid was confirmed by 99mTC scintigraphy. Incidental diagnosis of thyroid ectopia in asymptomatic adult patients is rare, and it should be considered on diagnostic imaging in case of an anterior midline cervical mass.

  6. THE FUTURE OF SPACECRAFT NUCLEAR PROPULSION

    OpenAIRE

    Jansen, Frank

    2014-01-01

    This paper summarizes the advantages of space nuclear power and propulsion systems. It describes the actual status of international power level dependent spacecraft nuclear propulsion missions, especially the high power EU-Russian MEGAHIT study including the Russian Megawatt-Class Nuclear Power Propulsion System, the NASA GRC project and the low and medium power EU DiPoP study. Space nuclear propulsion based mission scenarios of these studies are sketched as well.

  7. Additive Manufacturing of Aerospace Propulsion Components

    Science.gov (United States)

    Misra, Ajay K.; Grady, Joseph E.; Carter, Robert

    2015-01-01

    The presentation will provide an overview of ongoing activities on additive manufacturing of aerospace propulsion components, which included rocket propulsion and gas turbine engines. Future opportunities on additive manufacturing of hybrid electric propulsion components will be discussed.

  8. Induction of ectopic taste buds by SHH reveals the competency and plasticity of adult lingual epithelium

    Science.gov (United States)

    Castillo, David; Seidel, Kerstin; Salcedo, Ernesto; Ahn, Christina; de Sauvage, Frederic J.; Klein, Ophir D.; Barlow, Linda A.

    2014-01-01

    Taste buds are assemblies of elongated epithelial cells, which are innervated by gustatory nerves that transmit taste information to the brain stem. Taste cells are continuously renewed throughout life via proliferation of epithelial progenitors, but the molecular regulation of this process remains unknown. During embryogenesis, sonic hedgehog (SHH) negatively regulates taste bud patterning, such that inhibition of SHH causes the formation of more and larger taste bud primordia, including in regions of the tongue normally devoid of taste buds. Here, using a Cre-lox system to drive constitutive expression of SHH, we identify the effects of SHH on the lingual epithelium of adult mice. We show that misexpression of SHH transforms lingual epithelial cell fate, such that daughter cells of lingual epithelial progenitors form cell type-replete, onion-shaped taste buds, rather than non-taste, pseudostratified epithelium. These SHH-induced ectopic taste buds are found in regions of the adult tongue previously thought incapable of generating taste organs. The ectopic buds are composed of all taste cell types, including support cells and detectors of sweet, bitter, umami, salt and sour, and recapitulate the molecular differentiation process of endogenous taste buds. In contrast to the well-established nerve dependence of endogenous taste buds, however, ectopic taste buds form independently of both gustatory and somatosensory innervation. As innervation is required for SHH expression by endogenous taste buds, our data suggest that SHH can replace the need for innervation to drive the entire program of taste bud differentiation. PMID:24993944

  9. Normal mediastinal and hilar lymph nodes evaluated by 5 mm slice bolus injection CT scan

    International Nuclear Information System (INIS)

    Yamamoto, Takako; Tsukada, Hiroshi; Koizumi, Naoya; Akita, Shinichi; Oda, Junichi; Sakai, Kunio

    1995-01-01

    We evaluated the number and size of normal mediastinal and hilar lymph nodes by 5 mm slice bolus injection CT (12 patients), compared with 10 mm slice CT (12 patients). More lymph nodes were clearly demonstrated by 5 mm slice CT than by 10 mm slice CT. Especially left-sided tracheobronchial (no.4), subaortic (no.5), subcarinal (no.7) and hilar lymph nodes were clearly visible. We concluded 5 mm slice bolus injection CT was useful to evaluate mediastinal and hilar lymph nodes. (author)

  10. Development of superconducting ship propulsion system

    International Nuclear Information System (INIS)

    Sakuraba, Junji; Mori, Hiroyuki; Hata, Fumiaki; Sotooka, Koukichi

    1991-01-01

    When we plan displacement-type monohull high speed vessels, it is difficult to get the hull form with the wave-making resistance minimum, because the stern shape is restricted by arrangement of propulsive machines and shafts. A small-sized and light-weight propulsive machines will reduce the limit to full form design. Superconducting technology will have capability of realizing the small-sized and light-weight propulsion motor. The superconducting electric propulsion system which is composed of superconducting propulsion motors and generators, seems to be an ideal propulsion system for future vehicles. We have constructed a 480 kW superconducting DC homopolar laboratory test motor for developing this propulsion system. The characteristic of this motor is that it has a superconducting field winding and a segmented armature drum. The superconducting field winding which operates in the persistent current mode, is cooled by a condensation heat exchanger and helium refigerating system built into the cryostat of the superconducting field winding. The operating parameters of this motor agreed well with the design parameters. Using the design concepts of this motor, we have conceptually designed a 150,000-200,000 PS superconducting electric propulsive system for a displacement-type monohull high speed ship. (author)

  11. Precision multiloop (PM Design with space closing circles for lingual orthodontics

    Directory of Open Access Journals (Sweden)

    Mugdha P Mankar

    2016-01-01

    Full Text Available The proficiency of ancient orthodontics has been benefitted colossally and is being continually promoted over the present, by use of multiple loop wires designed for correction of dentoalveolar malocclusions. The presented discussion provides an insight into a simple, frictionless biomechanical concept of anterior space closure in lingual orthodontics by means of precision multiloop design with incorporated space closing circles. A multiple loop wire design has been demonstrated where the entire interbracket distance is used as loop area.

  12. Software To Secure Distributed Propulsion Simulations

    Science.gov (United States)

    Blaser, Tammy M.

    2003-01-01

    Distributed-object computing systems are presented with many security threats, including network eavesdropping, message tampering, and communications middleware masquerading. NASA Glenn Research Center, and its industry partners, has taken an active role in mitigating the security threats associated with developing and operating their proprietary aerospace propulsion simulations. In particular, they are developing a collaborative Common Object Request Broker Architecture (CORBA) Security (CORBASec) test bed to secure their distributed aerospace propulsion simulations. Glenn has been working with its aerospace propulsion industry partners to deploy the Numerical Propulsion System Simulation (NPSS) object-based technology. NPSS is a program focused on reducing the cost and time in developing aerospace propulsion engines

  13. Should colloid boluses be prioritized over crystalloid boluses for the management of dengue shock syndrome in the presence of ascites and pleural effusions?

    Directory of Open Access Journals (Sweden)

    Weerasinghe Mindu

    2011-02-01

    Full Text Available Abstract Background Although the WHO guideline for the management of dengue fever considers the presence of ascites or pleural effusions in the diagnosis of DSS, it does not emphasize the importance of their presence when selecting fluids for resuscitation. Case presentation We highlight three patients with DSS who received boluses of crystalloids on priority basis as recommended by WHO guidelines during resuscitation. All three patients had varying degrees of third space fluid loss (ascites and pleural effusions at the time of development of DSS. Ascites and pleural effusions were detected in all 3 patients at the time of shock irrespective of whether iv fluids were given or not. All three patients had documented liver involvement at the time of shock evidenced by elevation of AST (4800 iu/L, 5000 iu/L and 1960 iu/L. One patient who had profound shock died 6 hours after admission with evidence of acute pulmonary oedema in the convalescence phase. All of them needed CPAP ventilator support and potent diuretics. Conclusions We therefore feel that resuscitation of patients with DSS who already have third space fluid accumulation with crystalloid boluses on priority basis may contribute to recovery phase pulmonary oedema.

  14. 21 CFR 520.1720a - Phenylbutazone tablets and boluses.

    Science.gov (United States)

    2010-04-01

    ... Section 520.1720a Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...-mg or 1-g tablets, or 2- or 4-g boluses, in dogs and horses. (2) Nos. 000010 and 059130 for use of 100- or 200-mg or 1-g tablets in dogs and horses. (3) Nos. 000856 and 061623 for use of 100-mg or 1-g...

  15. Continuous transversus abdominis plane block vs intermittent bolus for analgesia after abdominal surgery: a randomized trial

    Directory of Open Access Journals (Sweden)

    Rao Kadam V

    2017-07-01

    Full Text Available Vasanth Rao Kadam,1 Roelof M Van Wijk,1 John L Moran,2 Shantan Ganesh,3 A Kumar,1 Rajesh Sethi,1 Patricia Williams2,4 1Department of Anaesthesia, The Queen Elizabeth Hospital, School of Medicine, University of Adelaide, Adelaide, SA, 2Intensive Care Unit, The Queen Elizabeth Hospital, School of Medicine, University of Adelaide, Adelaide, SA, 3Department of Surgery, The Queen Elizabeth Hospital, School of Medicine, University of Adelaide, Adelaide, SA, 4Department of Epidemiology and Preventive Medicine, School Public Health and Preventive Medicine, Australian and New Zealand Intensive Care Research Centre, Monash University, Melbourne, VIC, Australia Background: Continuous and intermittent bolus techniques of transversus abdominis plane (TAP blocks have been used for analgesia after abdominal surgery. Although both are effective, there are no studies comparing them. The aim of this study is to compare analgesia and cost-effectiveness between these groups.Methods: After obtaining ethical approval, 20 American Society of Anesthesiologists ASA grade I to III patients undergoing elective abdominal surgery were recruited with 10 patients allocated to each arm. Bilateral ultrasound-guided TAP blocks were performed with an initial bolus of 0.5% ropivacaine 20 mL per side, followed by catheter insertion. After surgery, the continuous infusion group received 0.2% ropivacaine 8 mL/hour on each side and the intermittent bolus group received doses of 0.2% ropivacaine 20 mL per side every 8 hours for 48 hours. Both groups received intravenous fentanyl patient-controlled analgesia and regular oral paracetamol. Parameters recorded included numerical rating scores for pain and post-operative analgesic consumption at baseline (time 0 and at 1 hour, 1 day and 2 days post-operatively. The duration of catheter insertion, complications, patient satisfaction and information regarding costs were also recorded. Patient satisfaction was assessed utilizing a 4-point

  16. Fusion propulsion systems

    International Nuclear Information System (INIS)

    Haloulakos, V.E.; Bourque, R.F.

    1989-01-01

    The continuing and expanding national efforts in both the military and commercial sectors for exploration and utilization of space will require launch, assembly in space, and orbital transfer of large payloads. The currently available delivery systems, utilizing various forms of chemical propulsion, do not have the payload capacity to fulfill the planned missions. National planning documents such as Air Force Project Forecast II and the National Commission on Space Report to the President contain numerous missions and payload delivery schedules that are beyond the present capabilities of the available systems, such as the Space Shuttle and the Expendable Launch Vehicles (ELVs). The need, therefore, is very pressing to design, develop, and deploy propulsion systems that offer a quantum level increase in delivered performance. One such potential system is fusion propulsion. This paper summarizes the result of an Air Force Astronautics Laboratory (AFAL) sponsored study of fusion propulsion conducted by the McDonnell Douglas Astronautics Company (MDAC), and its subcontractor General Atomics This study explored the potential of fusion propulsion for Air Force missions. Fusion fuels and existing confinement concepts were evaluated according to elaborate criteria. Two fuels, deuterium-tritium and deuterium-helium 3 (D- 3 He) were considered worthy of further consideration. D- 3 He was selected as the most attractive for this Air Force study. The colliding translating compact torus confinement concept was evaluated in depth and found to possibly possess the low mass and compactness required. Another possible concept is inertial confinement with the propellant surrounding the target. 5 refs., 5 figs., 8 tabs

  17. Cold Gas Micro Propulsion

    NARCIS (Netherlands)

    Louwerse, M.C.

    2009-01-01

    This thesis describes the development of a micro propulsion system. The trend of miniaturization of satellites requires small sized propulsion systems. For particular missions it is important to maintain an accurate distance between multiple satellites. Satellites drift apart due to differences in

  18. INFLUENCE OF AGE ON SWALLOWS OF A HIGHLY VISCOUS LIQUID BOLUS

    Directory of Open Access Journals (Sweden)

    Weslania Viviane NASCIMENTO

    2015-03-01

    Full Text Available Background Swallow function has a decline with aging, mainly in those over 80 years old. In the population over 69 years, about 11% of subjects reported symptoms indicative of significant dysphagia. Objectives Our objective was to evaluate the hypothesis that older asymptomatic subjects before 80 years old have compensations to sustain a safe and efficient swallow, at least with swallows of liquid bolus. Methods We performed videofluoroscopic evaluation of swallows in 55 normal volunteers, a younger group with 33 subjects (16 men and 17 women aged 19 to 55 years, mean 35.5±9.8 years, and an older group with 22 subjects (15 men and 7 women aged 56 to 77 years, mean 64.8±6.8 years. The subjects swallowed in duplicate 5 mL and 10 mL of liquid barium with a pH of 7.9, density of 1.82 g/cm3, and viscosity of 895 cp. Results The mean duration of pharyngeal transit, pharyngeal clearance, upper esophageal sphincter opening, hyoid movement and oral-pharyngeal transit were longer in the younger group compared with the older group. The relation between pharyngeal clearance duration and hyoid movement duration was similar in younger and older subjects, for 5 mL and 10 mL bolus volumes. Conclusions On average, a highly viscous liquid bolus crosses the pharynx faster in older subjects (56-77 years old than in younger subjects (19-55 years old, which suggested an adaptation to the aging process to maintain a safe swallow.

  19. The influence of a slow-release multi-trace element ruminal bolus on trace element status, number of ovarian follicles and pregnancy outcomes in synchronized Afshari ewes

    Science.gov (United States)

    Abdollahi, E.; Kohram, H.; Shahir, M. H.; Nemati, M. H.

    2015-01-01

    Published data on the effects of ruminal bolus on the number of ovulatory follicles in ewes does not exist. The present study determined the effects of a ruminal bolus on trace element status, follicular dynamics and reproductive performance in ewes. Eighty Afshari cycling ewes were synchronized during breeding season using CIDR for 14 days and assigned to 4 groups (n=20); group 1 received a single Ferrobloc bolus four weeks prior to CIDR insertion following 400 IU eCG on CIDR removal, group 2 received two boluses four weeks prior to CIDR insertion following 400 IU eCG on CIDR removal, group 3 received only 400 IU eCG on CIDR removal and group 4 (control) received no bolus and no eCG. Transrectal ultrasonography was done to monitor the ovarian follicles on the day of CIDR removal and a day later. Results showed that boluses increased the status of copper, selenium and iodine on mating day and days 90 to 100 of gestation. Ruminal bolus did not significantly increase the number of different classes of ovarian follicles in ewes fed a diet meeting all trace mineral requirements. All ewes eventually became pregnant with 1 or 2 boluses but the multiple births rate (80%) was higher (P<0.05) after 2 boluses compared to the other groups. PMID:27175153

  20. Bolus fluid therapy and sodium homeostasis in paediatric gastroenteritis.

    Science.gov (United States)

    Freedman, Stephen B; Geary, Denis F

    2013-03-01

    The study aims to assess the risk of developing hyponatraemia when large-volume bolus fluid rehydration therapy is administered. We conducted a prospective randomised study in a tertiary-care centre emergency department. Participants included children with gastroenteritis and dehydration requiring intravenous rehydration. They were randomised to receive 60 mL/kg (large) or 20 mL/kg (standard) 0.9% saline bolus followed by maintenance 0.9% saline for 3 h. Biochemical tests were performed at baseline and 4 h. The primary outcome measure was the development of hyponatraemia at 4 h. Secondary outcome measures were (i) change in sodium relative to baseline value; (ii) magnitude of decrease among those who experienced a decrease; (iii) risk of hypernatraemia; (iv) correlations between urine parameters and hyponatraemia; and (v) fluid overload. Eighty-four of 224 (38%) participants were hyponatraemic at baseline. At 4 h, 22% (48/217) had a dysnatraemia, and similar numbers of children were hyponatraemic in both groups: large (23% (26/112)) versus standard (21% (22/105)) (P = 0.69). Among initially hyponatraemic children, 63% (30/48) who received large-volume rehydration and 44% (15/34) of those administered standard rehydration were isonatraemic at 4 h (P = 0.10). Overall, children who received 60 mL/kg experienced a larger mean increase (1.6 ± 2.4 mEq/L vs. 0.9 ± 2.2 mEq/L; P = 0.04) and were less likely to experience a sodium decrease of ≥2 mEq/L (8/112 vs. 17/105; P = 0.04) than those administered 20 mL/kg. Large-volume bolus rehydration therapy with 0.9% saline is safe. It does not promote the development of hyponatraemia over the short term, but hastens the resolution of baseline hyponatraemia. © 2013 The Authors. Journal of Paediatrics and Child Health © 2013 Paediatrics and Child Health Division (Royal Australasian College of Physicians).

  1. Congenital hypothyroidism. The role of nuclear medicine in diagnosis: a case of lingual thyroid

    International Nuclear Information System (INIS)

    Maggs, J.; Cotter, A.; Bartholomeusz, D.; Chatterton, B.

    2005-01-01

    Hypothyroidism present from birth is a devastating condition and causes cretinism, which results in delayed development and mental retardation unless treated very early. All neonates in Australia are screened by a blood test when about two days old to exclude hypothyroidism (and several other biochemical conditions). A non-invasive nuclear scan may be able to recognise the cause of neonatal hypothyroidism: 1. Thyroid dysgenesis, (anatomical anomalies) including aplasia or hypoplasia of the thyroid gland; and ectopy of the thyroid, often with hypoplasia, in which there is insufficient tissue to match the demands of the infant or growing child. The abnormal anatomy is seen on thyroid scanning. 2. Dyshormonogencsis, (organification defects) a serious error in thyroid hormone synthesis. In general, thyroid trapping of pertechnctate or iodine will be increased, and demonstrated on the radionuclide study. 3. Hypopituitarism (secondary hypothyroidism) due to pituitary aplasia or midline brain developmental defects. There may also be hypothalamic dysfunction (tertiary hypothyroidism). An anatomically normal thyroid will show reduced uptake. Lingual thyroid is a rare developmental anomaly caused by failure of migration of the thyroid gland to its normal position in the neck. The incidence is relatively rare and sex incidence is four or five to one in favour of females. If untreated, there are sequelae of hypothyroidism, or growth of the mass in base of the tongue to the mass of a normal thyroid gland, which may cause respiratory compression. Thyroid malignancies may also be more frequent. This poster reports a case of lingual thyroid in a 19-day-old baby girl with biochemically diagnosed hypothyroidism. T4 = 9 (N > 12), TSH = 80, (N < 5). Scanning with a pinhole collimator 20min after IV injection of 40 MBq of Pertechnetate showed the only uptake to be in the base of the tongue, a lingual thyroid. Uptake was estimated at 2%, (N not available in infants)

  2. Neural network pattern recognition of lingual-palatal pressure for automated detection of swallow.

    Science.gov (United States)

    Hadley, Aaron J; Krival, Kate R; Ridgel, Angela L; Hahn, Elizabeth C; Tyler, Dustin J

    2015-04-01

    We describe a novel device and method for real-time measurement of lingual-palatal pressure and automatic identification of the oral transfer phase of deglutition. Clinical measurement of the oral transport phase of swallowing is a complicated process requiring either placement of obstructive sensors or sitting within a fluoroscope or articulograph for recording. Existing detection algorithms distinguish oral events with EMG, sound, and pressure signals from the head and neck, but are imprecise and frequently result in false detection. We placed seven pressure sensors on a molded mouthpiece fitting over the upper teeth and hard palate and recorded pressure during a variety of swallow and non-swallow activities. Pressure measures and swallow times from 12 healthy and 7 Parkinson's subjects provided training data for a time-delay artificial neural network to categorize the recordings as swallow or non-swallow events. User-specific neural networks properly categorized 96 % of swallow and non-swallow events, while a generalized population-trained network was able to properly categorize 93 % of swallow and non-swallow events across all recordings. Lingual-palatal pressure signals are sufficient to selectively and specifically recognize the initiation of swallowing in healthy and dysphagic patients.

  3. Comparison between intravenous boluses versus infusion of tranexamic acid (TXA) to reduce bleeding in paediatric cyanotic congenital heart disease (CHD) surgeries

    International Nuclear Information System (INIS)

    Junejo, F.; Irfan, M.; Akhtar, M.I.; Hamid, M.; Ahmed, S.S.

    2018-01-01

    To compare the intravenous boluses and intravenous continuous infusion of tranexamic acid (TXA) to reduce postoperative bleeding in cyanotic congenital heart disease surgeries. Study Design:Single-blinded randomised clinical trial. Place and Duration of Study:Anaesthesia Department, The Aga Khan University Hospital, Karachi, from July 2016 to April 2017. Methodology:Sixty patients of cyanotic congenital heart disease, undergoing either palliative or corrective surgery involving cardiopulmonary bypass (CPB), were recruited. These 60 patients were divided randomly into two groups. The infusion group received intravenous infusion of TXA at 5 mg/kg/hour while the bolus group received three intravenous boluses of 10 mg/kg after induction, after going to bypass and after protamine reversal. Data was collected through predesigned proforma. There were two primary outcomes: postoperative bleeding in the first 24 hours, and chest closure time. Results:Postoperative bleeding was 13.94 (10.27-20.18) ml/kg in the first 24 hours in infusion group and 15.05 (9.04-23.50) ml/kg in the bolus group. Chest closure time was 38.5 (25-45) in infusion group and 30 (20-46.25) minutes in the bolus group. There was no statistically significant and clinical difference between both groups regarding postoperative bleeding in the first 24 hours and chest closure time. Conclusion:These infusion and bolus groups had comparable postoperative bleeding and chest closure time. (author)

  4. Lunar Robotic Precursor Missions Using Electric Propulsion

    OpenAIRE

    Winski, Richard G.

    2006-01-01

    A trade study is carried out for the design of electric propulsion based lunar robotic precursor missions. The focus is to understand the relationships between payload mass delivered, electric propulsion power, and trip time. The results are compared against a baseline system using chemical propulsion with LOX/H2. The major differences between the chemical propulsion based and electric propulsion based systems are presented in terms of the payload mass and trip time. It is shown that solar e...

  5. A Review of Laser Ablation Propulsion

    International Nuclear Information System (INIS)

    Phipps, Claude; Bohn, Willy; Lippert, Thomas; Sasoh, Akihiro; Schall, Wolfgang; Sinko, John

    2010-01-01

    Laser Ablation Propulsion is a broad field with a wide range of applications. We review the 30-year history of laser ablation propulsion from the transition from earlier pure photon propulsion concepts of Oberth and Saenger through Kantrowitz's original laser ablation propulsion idea to the development of air-breathing 'Lightcraft' and advanced spacecraft propulsion engines. The polymers POM and GAP have played an important role in experiments and liquid ablation fuels show great promise. Some applications use a laser system which is distant from the propelled object, for example, on another spacecraft, the Earth or a planet. Others use a laser that is part of the spacecraft propulsion system on the spacecraft. Propulsion is produced when an intense laser beam strikes a condensed matter surface and produces a vapor or plasma jet. The advantages of this idea are that exhaust velocity of the propulsion engine covers a broader range than is available from chemistry, that it can be varied to meet the instantaneous demands of the particular mission, and that practical realizations give lower mass and greater simplicity for a payload delivery system. We review the underlying theory, buttressed by extensive experimental data. The primary problem in laser space propulsion theory has been the absence of a way to predict thrust and specific impulse over the transition from the vapor to the plasma regimes. We briefly discuss a method for combining two new vapor regime treatments with plasma regime theory, giving a smooth transition from one regime to the other. We conclude with a section on future directions.

  6. The application of DSA bolus chase technology in diagnosing the vascular disorders of lower extremities due to diabetes mellitus

    International Nuclear Information System (INIS)

    Ren Chongyang; Di Zhenhai; Mao Xuequn; Zou Rong; Zhang Jian; Wang Meirong; Li Quan

    2010-01-01

    Objective: To retrospectively evaluate the digital subtraction angiography (DSA) bolus chase technology in diagnosing the vascular disorders of lower extremities due to diabetes mellitus. Methods: From January 2004 to March 2010, DSA was performed in forty-five diabetes patients with suspicious vascular diseases of lower extremities. Among them, 24 cases (31 lower limbs)were examined with DSA bolus chase technology and the remaining 21 cases (21 lower limbs)were examined with traditional segmentational technique. The contrast dosage used in angiography, the total exposure time, the examination time and the imaging value for making diagnosis were analyzed and compared between two techniques. Results: For DSA bolus chase technology group, the contrast dosage used in angiography, the total exposure time and the examination time were 25.26 ml, 13.23 s and 37.26 min, respectively,with an average exposure of 101.65 pictures. For traditional segmentational technique group, the contrast dosage used in angiography, the total exposure time and the examination time were 130.00 ml, 52.38 s and 50.48 min, respectively, with an average exposure of 118.33 pictures. The percentage of high quality images in bolus chase technology group and in traditional segmentational technique group were 90.3% and 90.5%, respectively. All the images could meet the requirements for making a reliable diagnosis. Conclusion: Digital subtraction angiography by using bolus-chase technology can well demonstrate the vascular pathology of lower extremities caused by diabetes mellitus, obtain sufficient imaging information necessary for making a reliable diagnosis. DSA bolus chase technology is superior to traditional segmentational technique in shortening procedure time, reducing contrast medium dosage and decreasing radiation dose. (authors)

  7. Transient isolated lingual nerve neuropraxia associated with general anaesthesia and laryngeal mask use: two case reports and a review of the literature.

    LENUS (Irish Health Repository)

    Foley, E

    2012-02-01

    BACKGROUND: Transient, isolated lingual nerve neuropraxia is a rare complication following general anaesthesia. Reports implicate airway manipulation and we describe two new cases associated with laryngeal mask airway (LMA) and review the related English language literature. RESULTS: Unilateral numbness and loss of taste on the anterior tongue were the characteristic symptoms. Collation of literature data (median and range) with that from the new cases showed: patient age was 38 (20-61) years and female to male ratio was 1.2:1. Surgery time was 62.5 (20-150) min and symptom duration was 28 (7-120) days. CONCLUSION: Lingual neuropraxias reported have been transient and patients can be advised, despite disturbing symptoms, that recovery is anticipated in about 1 month. Lingual neuropraxia reports are becoming more frequent, perhaps associated with increasing LMA use. Research is recommended as modification to LMA cuff volume, pressure and\\/or position within the oral cavity might ameliorate the entity.

  8. Distribution of Y-receptors in murine lingual epithelia.

    Directory of Open Access Journals (Sweden)

    Maria D Hurtado

    Full Text Available Peptide hormones and their cognate receptors belonging to neuropeptide Y (NPY family mediate diverse biological functions in a number of tissues. Recently, we discovered the presence of the gut satiation peptide YY (PYY in saliva of mice and humans and defined its role in the regulation of food intake and body weight maintenance. Here we report the systematic analysis of expression patterns of all NPY receptors (Rs, Y1R, Y2R, Y4R, and Y5R in lingual epithelia in mice. Using four independent assays, immunohistochemistry, in situ hybridization, immunocytochemistry and RT PCR, we show that the morphologically different layers of the keratinized stratified epithelium of the dorsal layer of the tongue express Y receptors in a very distinctive yet overlapping pattern. In particular, the monolayer of basal progenitor cells expresses both Y1 and Y2 receptors. Y1Rs are present in the parabasal prickle cell layer and the granular layer, while differentiated keratinocytes display abundant Y5Rs. Y4Rs are expressed substantially in the neuronal fibers innervating the lamina propria and mechanoreceptors. Basal epithelial cells positive for Y2Rs respond robustly to PYY(3-36 by increasing intracellular Ca(2+ suggesting their possible functional interaction with salivary PYY. In taste buds of the circumvallate papillae, some taste receptor cells (TRCs express YRs localized primarily at the apical domain, indicative of their potential role in taste perception. Some of the YR-positive TRCs are co-localized with neuronal cell adhesion molecule (NCAM, suggesting that these TRCs may have synaptic contacts with nerve terminals. In summary, we show that all YRs are abundantly expressed in multiple lingual cell types, including epithelial progenitors, keratinocytes, neuronal dendrites and TRCs. These results suggest that these receptors may be involved in the mediation of a wide variety of functions, including proliferation, differentiation, motility, taste perception

  9. Pharmacokinetics of rocuronium after bolus and continuous infusion during halothane anaesthesia

    NARCIS (Netherlands)

    McCoy, E.P; Mirakhur, R.K; Maddineni, V.R; Wierda, J.MKH; Proost, Hans

    We have studied the pharmacokinetics of a single bolus of rocuronium (Org 9426), followed by an infusion, in eight patients during anaesthesia with halothane and nitrous oxide in oxygen. Neuromuscular block was monitored using train-of-four (TOF) stimulation and recording the force of contraction of

  10. Bi-Lingual Newspaper as an Expression of a Fake Multicultural Educational Policy in Israel

    Science.gov (United States)

    Baratz, Lea; Reingold, Roni; Abuhatzira, Hannah

    2011-01-01

    The current paper analyzes a unique educational text that may be used to follow the educational policy of the State of Israel towards the community of Jewish immigrants from Ethiopia. The text which was analyzed was a bi-lingual newspaper called "Nugget News" which is published under the sponsorship of the Israeli Ministry of Education,…

  11. Evidence of an increased pathogenic footprint in the lingual microbiome of untreated HIV infected patients

    Directory of Open Access Journals (Sweden)

    Dang Angeline T

    2012-07-01

    Full Text Available Abstract Background Opportunistic oral infections can be found in over 80% of HIV + patients, often causing debilitating lesions that also contribute to deterioration in nutritional health. Although appreciation for the role that the microbiota is likely to play in the initiation and/or enhancement of oral infections has grown considerably in recent years, little is known about the impact of HIV infection on host-microbe interactions within the oral cavity. In the current study, we characterize modulations in the bacterial composition of the lingual microbiome in patients with treated and untreated HIV infection. Bacterial species profiles were elucidated by microarray assay and compared between untreated HIV infected patients, HIV infected patients receiving antiretroviral therapy, and healthy HIV negative controls. The relationship between clinical parameters (viral burden and CD4+ T cell depletion and the loss or gain of bacterial species was evaluated in each HIV patient group. Results In untreated HIV infection, elevated viremia was associated with significantly higher proportions of potentially pathogenic Veillonella, Prevotella, Megasphaera, and Campylobacter species in the lingual microbiome than observed in healthy controls. The upsurge in the prevalence of potential pathogens was juxtaposed by diminished representation of commensal Streptococcus and Veillonella species. Colonization of Neisseria flavescens was lower in the lingual microbiome of HIV infected patients receiving antiretroviral therapy than in uninfected controls. Conclusions Our findings provide novel insights into the potential impact of HIV infection and antiretroviral therapy on the community structure of the oral microbiome, and implicate potential mechanisms that may increase the capacity of non-commensal species to gain a stronger foothold.

  12. Propulsive efficiency and non- expert swimmers performance

    Directory of Open Access Journals (Sweden)

    Tiago Barbosa

    2009-12-01

    Full Text Available Propulsive efficiency is one of the most interesting issues for competitive swimming researchers, has it presents significant relationships with the swimmer’s biophysical behavior and his/her performance. Although propulsive efficiency is a variable that has been quite studied in elite swimmers, there is no research on this issue in young and non-expert swimmers. Thus, the aim of this study was to: (i estimate the propulsive efficiency on non-expert swimmers; (ii identify biomechanical and anthropometrical parameters that are associated with propulsive efficiency; (iii identify the association between the propulsive efficiency and swim performance. Twenty-eight non-expert swimmers participated on this study. It was assessed the propulsive efficiency, biomechanical and anthropometrical parameters, as well as, the swim performance. The propulsive efficiency of non-expert swimmers is lower than data reported in the literature to higher competitive levels swimmers and there are no significant differences between boys and girls. It was also noted that several biomechanical and anthropometrical parameters, as well as, the swim performance are associated with the propulsive efficiency.

  13. The Effect of Bolus Volume on Hyoid Kinematics in Healthy Swallowing

    Directory of Open Access Journals (Sweden)

    Ahmed Nagy

    2014-01-01

    Full Text Available Hyoid movement in swallowing is biomechanically linked to closure of the laryngeal vestibule for airway protection and to opening of the upper esophageal sphincter. Studies suggest that the range of hyoid movement is highly variable in the healthy population. However, other aspects of hyoid movement such as velocity remain relatively unexplored. In this study, we analyze data from a sample of 20 healthy young participants (10 male to determine whether hyoid movement distance, duration, velocity, and peak velocity vary systematically with increases in thin liquid bolus volume from 5 to 20 mL. The temporal correspondence between peak hyoid velocity and laryngeal vestibule closure was also examined. The results show that maximum hyoid position and peak velocity increase significantly for 20 mL bolus volumes compared to smaller volumes, and that the timing of peak velocity is closely linked to achieving laryngeal vestibule closure. This suggests that generating hyoid movements with increased power is a strategy for handling larger volumes.

  14. Enteral nutrition for preterm infants: by bolus or continuous? An update

    Directory of Open Access Journals (Sweden)

    Valentina Bozzetti

    2017-06-01

    Full Text Available Optimization of nutritional management of preterm infants is crucial for achievement of their long-term health. Enteral nutrition is preferred to total parenteral nutrition (TPN because the former avoids complications related to vascular catheterization, sepsis, adverse effects of TPN, and fasting. Due to the lack of ability of preterm infants to coordinate suckling, swallowing, and breathing, tube feeding is necessary for most infants less than 1500 g to ensure sufficient feeding tolerance, to support optimal growth and to reduce the risk of aspiration. Therefore, feeding by orogastric or nasogastric tube using either continuous or intermittent bolus delivery of formula or human milk is common practice for these infants. Theoretical risks and benefits of both continuous nasogastric milk feeding and intermittent bolus milk feeding have been proposed. According to the literature, continuous nutrition could be preferred in smaller infants (as those with a birthweight below 1250 g or hemodynamically impaired infants; in stable growing infants nutrition can be administered intermittently as in healthy term infants.

  15. A mathematical model for the movement of food bolus of varying viscosities through the esophagus

    Science.gov (United States)

    Tripathi, Dharmendra

    2011-09-01

    This mathematical model is designed to study the influence of viscosity on swallowing of food bolus through the esophagus. Food bolus is considered as viscous fluid with variable viscosity. Geometry of esophagus is assumed as finite length channel and flow is induced by peristaltic wave along the length of channel walls. The expressions for axial velocity, transverse velocity, pressure gradient, volume flow rate and stream function are obtained under the assumptions of long wavelength and low Reynolds number. The impacts of viscosity parameter on pressure distribution, local wall shear stress, mechanical efficiency and trapping are numerically discussed with the help of computational results. On the basis of presented study, it is revealed that swallowing of low viscous fluids through esophagus requires less effort in comparison to fluids of higher viscosity. This result is similar to the experimental result obtained by Raut et al. [1], Dodds [2] and Ren et al. [3]. It is further concluded that the pumping efficiency increases while size of trapped bolus reduces when viscosity of fluid is high.

  16. Effects of copper oxide wire particle bolus therapy on trichostrongyle fecal egg counts in exotic artiodactylids.

    Science.gov (United States)

    Fontenot, Deidre K; Kinney-Moscona, Allyson; Kaplan, Ray M; Miller, James

    2008-12-01

    Four species of artiodactylids (scimitar-horned oryx [Oryx dama]), roan antelope [Hippotragus equinus], blackbuck [Antilope cervicapra]), and blesbok [Damaliscus pygargus phillipsi]) totaling 13 animals were treated with a one-time 12.5-g dose of copper oxide wire particles (COWPs) in a bolus form. Pretreatment, individual trichostrongyle fecal egg counts (FECs) were performed using the McMaster technique. Individual posttreatment FECs were performed every 7 days for 35 days beginning 7 days after bolus administration, and FEC reduction ratios (FECRRs) expressed as percentage reductions from pretreatment values were calculated every 7 days. Mean FECRRs for the 13 animals were 93% +/- 16%, 98% +/- 7%, 91% +/- 28%, 94% +/- 16%, and 90% +/- 13% at 7, 14, 21, 28, and 35 days posttreatment, respectively. These data demonstrate that COWPs in a bolus form were an effective method for reducing FEC in exotic artiodactylids. Based on this limited data, COWPs show promise as an anthelmintic alternative for exotic artiodactylids in zoologic collections.

  17. Research Opportunities in Space Propulsion

    Science.gov (United States)

    Rodgers, Stephen L.

    2007-01-01

    Rocket propulsion determines the primary characteristics of any space vehicle; how fast and far it can go, its lifetime, and its capabilities. It is the primary factor in safety and reliability and the biggest cost driver. The extremes of heat and pressure produced by propulsion systems push the limits of materials used for manufacturing. Space travel is very unforgiving with little room for errors, and so many things can go wrong with these very complex systems. So we have to plan for failure and that makes it costly. But what is more exciting than the roar of a rocket blasting into space? By its nature the propulsion world is conservative. The stakes are so high at every launch, in terms of payload value or in human life, that to introduce new components to a working, qualified system is extremely difficult and costly. Every launch counts and no risks are tolerated, which leads to the space world's version of Catch-22:"You can't fly till you flown." The last big 'game changer' in propulsion was the use of liquid hydrogen as a fuel. No new breakthrough, low cost access to space system will be developed without new efficient propulsion systems. Because there is no large commercial market driving investment in propulsion, what propulsion research is done is sponsored by government funding agencies. A further difficulty in propulsion technology development is that there are so few new systems flying. There is little opportunity to evolve propulsion technologies and to update existing systems with results coming out of research as there is in, for example, the auto industry. The biggest hurdle to space exploration is getting off the ground. The launch phase will consume most of the energy required for any foreseeable space exploration mission. The fundamental physical energy requirements of escaping earth's gravity make it difficult. It takes 60,000 kJ to put a kilogram into an escape orbit. The vast majority (-97%) of the energy produced by a launch vehicle is used

  18. Induction of ectopic taste buds by SHH reveals the competency and plasticity of adult lingual epithelium.

    Science.gov (United States)

    Castillo, David; Seidel, Kerstin; Salcedo, Ernesto; Ahn, Christina; de Sauvage, Frederic J; Klein, Ophir D; Barlow, Linda A

    2014-08-01

    Taste buds are assemblies of elongated epithelial cells, which are innervated by gustatory nerves that transmit taste information to the brain stem. Taste cells are continuously renewed throughout life via proliferation of epithelial progenitors, but the molecular regulation of this process remains unknown. During embryogenesis, sonic hedgehog (SHH) negatively regulates taste bud patterning, such that inhibition of SHH causes the formation of more and larger taste bud primordia, including in regions of the tongue normally devoid of taste buds. Here, using a Cre-lox system to drive constitutive expression of SHH, we identify the effects of SHH on the lingual epithelium of adult mice. We show that misexpression of SHH transforms lingual epithelial cell fate, such that daughter cells of lingual epithelial progenitors form cell type-replete, onion-shaped taste buds, rather than non-taste, pseudostratified epithelium. These SHH-induced ectopic taste buds are found in regions of the adult tongue previously thought incapable of generating taste organs. The ectopic buds are composed of all taste cell types, including support cells and detectors of sweet, bitter, umami, salt and sour, and recapitulate the molecular differentiation process of endogenous taste buds. In contrast to the well-established nerve dependence of endogenous taste buds, however, ectopic taste buds form independently of both gustatory and somatosensory innervation. As innervation is required for SHH expression by endogenous taste buds, our data suggest that SHH can replace the need for innervation to drive the entire program of taste bud differentiation. © 2014. Published by The Company of Biologists Ltd.

  19. Propulsion System and Orbit Maneuver Integration in CubeSats: Trajectory Control Strategies Using Micro Ion Propulsion

    Science.gov (United States)

    Hudson, Jennifer; Martinez, Andres; Petro, Andrew

    2015-01-01

    The Propulsion System and Orbit Maneuver Integration in CubeSats project aims to solve the challenges of integrating a micro electric propulsion system on a CubeSat in order to perform orbital maneuvers and control attitude. This represents a fundamentally new capability for CubeSats, which typically do not contain propulsion systems and cannot maneuver far beyond their initial orbits.

  20. Low contrast volume run-off CT angiography with optimized scan time based on double-level test bolus technique – feasibility study

    International Nuclear Information System (INIS)

    Baxa, Jan; Vendiš, Tomáš; Moláček, Jiří; Štěpánková, Lucie; Flohr, Thomas; Schmidt, Bernhard; Korporaal, Johannes G.; Ferda, Jiří

    2014-01-01

    Purpose: To verify the technical feasibility of low contrast volume (40 mL) run-off CT angiography (run-off CTA) with the individual scan time optimization based on double-level test bolus technique. Materials and methods: A prospective study of 92 consecutive patients who underwent run-off CTA performed with 40 mL of contrast medium (injection rate of 6 mL/s) and optimized scan times on a second generation of dual-source CT. Individual optimized scan times were calculated from aortopopliteal transit times obtained on the basis of double-level test bolus technique – the single injection of 10 mL test bolus and dynamic acquisitions in two levels (abdominal aorta and popliteal arteries). Intraluminal attenuation (HU) was measured in 6 levels (aorta, iliac, femoral and popliteal arteries, middle and distal lower-legs) and subjective quality (3-point score) was assessed. Relations of image quality, test bolus parameters and arterial circulation involvement were analyzed. Results: High mean attenuation (HU) values (468; 437; 442; 440; 342; 274) and quality score in all monitored levels was achieved. In 91 patients (0.99) the sufficient diagnostic quality (score 1–2) in aorta, iliac and femoral arteries was determined. A total of 6 patients (0.07) were not evaluable in distal lower-legs. Only the weak indirect correlation of image quality and test-bolus parameters was proved in iliac, femoral and popliteal levels (r values: −0.263, −0.298 and −0.254). The statistically significant difference of the test-bolus parameters and image quality was proved in patients with occlusive and aneurysmal disease. Conclusion: We proved the technical feasibility and sufficient quality of run-off CTA with low volume of contrast medium and optimized scan time according to aortopopliteal transit time calculated from double-level test bolus

  1. The influence of carbon monoxide bolus on the measurement of total haemoglobin mass using the optimized CO-rebreathing method

    International Nuclear Information System (INIS)

    Turner, G; Richardson, A J; Maxwell, N S; Pringle, J S M; Ingham, S A; Fudge, B W

    2014-01-01

    The optimized carbon monoxide (CO) rebreathing method (oCOR-method) is routinely used to measure total haemoglobin mass (tHbmass). The tHbmass measure is subject to a test-retest typical error of ∼2%, mostly from the precision of carboxyhaemoglobin (HbCO) measurement. We hypothesized that tHbmass would be robust to differences in the bolus of CO administered during the oCOR-method. Twelve participants (ten males and two females; age 27 ± 6 yr, height 177 ± 11 cm and mass 73.9 ± 12.1 kg) completed the oCOR-method on four occasions. Different bolus of CO were administered (LOW: 0.6 ml kg −1 ; MED 1 : 1.0 ml kg −1  and HIGH: 1.4 ml kg −1 ); to determine the reliability of MED 1 , a second trial was conducted (MED 2 ). tHbmass was found to be significantly less from the HIGH CO bolus (776 ± 148 g) when compared to the LOW CO (791 ± 149 g) or MED 1  CO (788 ± 149 g) trials. MED 2  CO was 785 ± 150 g. The measurement of tHbmass is repeatable to within 0.8%, but a small and notable difference was seen when using a HIGH CO bolus (1.4 to 1.9% less), potentially due to differences in CO uptake kinetics. Previously, an improved precision of the oCOR-method was thought to require a higher bolus of CO (i.e. larger ▵%HbCO), as commercial hemoximeters only estimate %HbCO levels to a single decimal place (usually ± 0.1%). With the new hemoximeter used in this study, a bolus of 1.0 ml kg −1  allows adequate precision with acceptable safety. (note)

  2. Differential Response Pattern of Oropharyngeal Pressure by Bolus and Dry Swallows.

    Science.gov (United States)

    Hasegawa, Mana; Kurose, Masayuki; Okamoto, Keiichiro; Yamada, Yoshiaki; Tsujimura, Takanori; Inoue, Makoto; Sato, Taisuke; Narumi, Takatsune; Fujii, Noritaka; Yamamura, Kensuke

    2018-02-01

    The aim of this study was to determine if bolus and dry swallow showed similar pressure changes in the oropharynx using our newly developed device. A unique character of it includes that baropressure can be measured with the sensor being placed in the balloon and can assess the swallowing mechanics in terms of pressure changes in the oropharynx with less influences of direct contacts of boluses and oropharyngeal structures during swallow indirectly. Fifteen healthy subjects swallowed saliva (dry), 15 ml of water, 45 ml of water, and 15 ml of two different types of food in terms of viscosity (potage soup-type and mayonnaise-type foods). Suprahyoid muscle activity was recorded simultaneously. Three parameters, area under the curve (AUC), peak amplitude, and duration of pressure, were analyzed from each swallow. Almost all of the bolus swallowing events had biphasic baropressure responses consisting of an early phase and late phase (99%), whereas 90% of the saliva swallowing events had a single phase. AUC, peak, and duration displayed greater effects during the late phase than during the early phase. Baropressure of the early phase, but not of the late phase, significantly increased with increasing volume; however, small but significant viscosity effects on pressure were seen during both phases. Peak pressure of the late phase was preceded by maximum muscle activity, whereas that of the early phase was seen when muscle activity displayed a peak response. These findings indicated that our device with the ability to measure baropressure has the potential to provide additional parameter to assess the swallow physiology, and biphasic baropressure responses in the early and late phases could reflect functional aspects of the swallowing reflexes.

  3. Split-bolus single-phase cardiac multidetector computed tomography for reliable detection of left atrial thrombus. Comparison to transesophageal echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Staab, W.; Zwaka, P.A.; Sohns, J.M.; Schwarz, A.; Lotz, J. [University Medical Center Goettingen Univ. (Germany). Inst. for Diagnostic and Interventional Radiology; Sohns, C.; Vollmann, D.; Zabel, M.; Hasenfuss, G. [Goettingen Univ. (Germany). Dept. of Cardiology and Pneumology; Schneider, S. [Goettingen Univ. (Germany). Dept. of Medical Statistics

    2014-11-15

    Evaluation of a new cardiac MDCT protocol using a split-bolus contrast injection protocol and single MDCT scan for reliable diagnosis of LA/LAA thrombi in comparison to TEE, optimizing radiation exposure and use of contrast agent. A total of 182 consecutive patients with drug refractory AF scheduled for PVI (62.6% male, mean age: 64.1 ± 10.2 years) underwent routine diagnostic work including TEE and cardiac MDCT for the evaluation of LA/LAA anatomy and thrombus formation between November 2010 and March 2012. Contrast media injection was split into a pre-bolus of 30 ml and main bolus of 70 ml iodinated contrast agent separated by a short time delay. In this study, split-bolus cardiac MDCT identified 14 of 182 patients with filling defects of the LA/LAA. In all of these 14 patients, abnormalities were found in TEE. All 5 of the 14 patients with thrombus formation in cardiac MDCT were confirmed by TEE. MDCT was 100% accurate for thrombus, with strong but not perfect overall results for SEC equivalent on MDCT.

  4. TU-F-CAMPUS-I-01: Investigation of the Effective Dose From Bolus Tracking Acquisitions at Different Anatomical Locations in the Chest for CT

    Energy Technology Data Exchange (ETDEWEB)

    Nowik, P; Bujila, R; Merzan, D [Dept. of Medical Physics, Karolinska University Hospital, Stockholm (Sweden)

    2015-06-15

    Purpose: Stationary table acquisitions (Bolus tracking) in X-ray Computed Tomography (CT) can Result in dose length products (DLP) comparable to spiral scans. It is today unclear whether or not the effective dose (E) for Bolus Tracking can be approximated using target region specific conversion factors (E/DLP). The purpose of this study was to investigate how E depends on the anatomical location of the Bolus Tracking in relation to Chest CT scans with the same DLP. Methods: Effective doses were approximated for the ICRP 110 adult Reference Male (AM) and adult Reference Female (FM) computational voxel phantoms using software for CT dose approximations (pre-simulated MC data). The effective dose was first approximated for a Chest CT scan using spiral technique and a CTDIvol (32 cm) of 6 mGy. The effective dose from the spiral scan was then compared to E approximated for contiguous Bolus Tracking acquisitions (1 cm separation), with a total collimation of 1 cm, over different locations of the chest of the voxel phantoms. The number of rotations used for the Bolus Tracking acquisitions was adjusted to yield the same DLP (32 cm) as the spiral scan. Results: Depending on the anatomical location of the Bolus Tracking, E ranged by factors of 1.3 to 6.8 for the AM phantom and 1.4 to 3.3 for the AF phantom, compared to the effective dose of the spiral scans. The greatest E for the Bolus Tracking acquisitions was observed for anatomical locations coinciding with breast tissue. This can be expected as breast tissue has a high tissue weighting factor in the calculation of E. Conclusion: For Chest CT scans, the effective dose from Bolus Tracking is highly dependent on the anatomical location where the scan is administered and will not always accurately be represented using target region specific conversion factors.

  5. Poster - 38: On the physical and dosimetric properties of 3D printed electron bolus fabricated using polylactic acid

    Energy Technology Data Exchange (ETDEWEB)

    Sasaki, David; Jensen, Martin; Rickey, Daniel W; Dubey, Arbind; Harris, Chad; McCurdy, Boyd [CancerCare Manitoba, CancerCare Manitoba, CancerCare Manitoba, CancerCare Manitoba, CancerCare Manitoba, CancerCare Manitoba (Canada)

    2016-08-15

    Purpose: 3D printing technology could simplify and improve electron bolus fabrication. The purpose of this study was to characterize the density, dimensional accuracy, uniformity, and attenuation of PLA boluses fabricated with a low-cost 3D printer. Methods: Several solid square slabs were printed with specific requested dimensions and 100% infill using different fill patterns. These pieces were imaged using an x-ray flat panel imager in order to check for uniformity of the prints. Percentage depth doses (PDDs) were measured downstream of the slabs in solid water using a parallel plate chamber and compared to measurements in water in order to characterize attenuation. The dimensions of the PLA slabs were measured using digital calipers. The slabs were also weighed to find their density. Results: The fill pattern used to create boluses can affect the attenuation of the bolus. Fill patterns should be chosen carefully and quality assurance should be done for each printed piece. PLA causes the electron PDD to shift towards shallower depths, compared to water, by 1.7 mm for each centimeter of PLA. Agreement with design dimensions was within 1 mm in the plane of the printer bed, and within 1/3 of a millimeter (roughly the thickness of a single layer), perpendicular to the printer bed. Average density was in the range 1.20 – 1.22. Conclusions: 3D printing shows great promise for use in fabricating electron bolus. This work indicates that printed PLA can be a suitable material provided the increased attenuation is properly accounted for.

  6. Poster - 38: On the physical and dosimetric properties of 3D printed electron bolus fabricated using polylactic acid

    International Nuclear Information System (INIS)

    Sasaki, David; Jensen, Martin; Rickey, Daniel W; Dubey, Arbind; Harris, Chad; McCurdy, Boyd

    2016-01-01

    Purpose: 3D printing technology could simplify and improve electron bolus fabrication. The purpose of this study was to characterize the density, dimensional accuracy, uniformity, and attenuation of PLA boluses fabricated with a low-cost 3D printer. Methods: Several solid square slabs were printed with specific requested dimensions and 100% infill using different fill patterns. These pieces were imaged using an x-ray flat panel imager in order to check for uniformity of the prints. Percentage depth doses (PDDs) were measured downstream of the slabs in solid water using a parallel plate chamber and compared to measurements in water in order to characterize attenuation. The dimensions of the PLA slabs were measured using digital calipers. The slabs were also weighed to find their density. Results: The fill pattern used to create boluses can affect the attenuation of the bolus. Fill patterns should be chosen carefully and quality assurance should be done for each printed piece. PLA causes the electron PDD to shift towards shallower depths, compared to water, by 1.7 mm for each centimeter of PLA. Agreement with design dimensions was within 1 mm in the plane of the printer bed, and within 1/3 of a millimeter (roughly the thickness of a single layer), perpendicular to the printer bed. Average density was in the range 1.20 – 1.22. Conclusions: 3D printing shows great promise for use in fabricating electron bolus. This work indicates that printed PLA can be a suitable material provided the increased attenuation is properly accounted for.

  7. Mirror fusion propulsion system - A performance comparison with alternate propulsion systems for the manned Mars mission

    International Nuclear Information System (INIS)

    Deveny, M.; Carpenter, S.; O'connell, T.; Schulze, N.

    1993-06-01

    The performance characteristics of several propulsion technologies applied to piloted Mars missions are compared. The characteristics that are compared are Initial Mass in Low Earth Orbit (IMLEO), mission flexibility, and flight times. The propulsion systems being compared are both demonstrated and envisioned: Chemical (or Cryogenic), Nuclear Thermal Rocket (NTR) solid core, NTR gas core, Nuclear Electric Propulsion (NEP), and a mirror fusion space propulsion system. The proposed magnetic mirror fusion reactor, known as the Mirror Fusion Propulsion System (MFPS), is described. The description is an overview of a design study that was conducted to convert a mirror reactor experiment at Lawrence Livermore National Lab (LLNL) into a viable space propulsion system. Design principles geared towards minimizing mass and maximizing power available for thrust are identified and applied to the LLNL reactor design, resulting in the MFPS. The MFPS' design evolution, reactor and fuel choices, and system configuration are described. Results of the performance comparison shows that the MFPS minimizes flight time to 60 to 90 days for flights to Mars while allowing continuous return-home capability while at Mars. Total MFPS IMLEO including propellant and payloads is kept to about 1,000 metric tons. 50 refs

  8. Failure Rates of Orthodontic Fixed Lingual Retainers bonded with Two Flowable Light-cured Adhesives: A Comparative Prospective Clinical Trial.

    Science.gov (United States)

    Talic, Nabeel F

    2016-08-01

    This comparative prospective randomized clinical trial examined the in vivo failure rates of fixed mandibular and maxillary lingual retainers bonded with two light-cured flowable composites over 6 months. Consecutive patients were divided into two groups on a 1:1 basis. Two hundred fixed lingual retainers were included, and their failures were followed for 6 months. One group (n = 50) received retainers bonded with a nano-hybrid composite based on nano-optimized technology (Tetric-N-Flow, Ivoclar Vivadent). Another group (n = 50) received retainers bonded with a low viscosity (LV) composite (Transbond Supreme LV, 3M Unitek). There was no significant difference between the overall failure rates of mandibular retainers bonded with Transbond (8%) and those bonded with Tetric-N-Flow (18%). However, the odds ratio for failure using Tetric-N-flow was 2.52-fold greater than that of Transbond. The failure rate of maxillary retainers bonded with Transbond was higher (14%), but not significantly different, than that of maxillary retainers bonded with Tetric-N-flow (10%). There was no significant difference in the estimated mean survival times of the maxillary and mandibular retainers bonded with the two composites. Both types of composites tested in the current study can be used to bond fixed maxillary and mandibular lingual retainers, with low failure rates.

  9. Analysis and implementation of cross lingual short message service spam filtering using graph-based k-nearest neighbor

    Science.gov (United States)

    Ayu Cyntya Dewi, Dyah; Shaufiah; Asror, Ibnu

    2018-03-01

    SMS (Short Message Service) is on e of the communication services that still be the main choice, although now the phone grow with various applications. Along with the development of various other communication media, some countries lowered SMS rates to keep the interest of mobile users. It resulted in increased spam SMS that used by several parties, one of them for advertisement. Given the kind of multi-lingual documents in a message SMS, the Web, and others, necessary for effective multilingual or cross-lingual processing techniques is becoming increasingly important. The steps that performed in this research is data / messages first preprocessing then represented into a graph model. Then calculated using GKNN method. From this research we get the maximum accuracy is 98.86 with training data in Indonesian language and testing data in indonesian language with K 10 and threshold 0.001.

  10. The reliability and validity of passive leg raise and fluid bolus to assess fluid responsiveness in spontaneously breathing emergency department patients

    DEFF Research Database (Denmark)

    Duus, Nicolaj; Shogilev, Daniel J; Skibsted, Simon

    2015-01-01

    PURPOSE: We investigated the reproducibility of passive leg raise (PLR) and fluid bolus (BOLUS) using the Non-Invasive Cardiac Output Monitor (NICOM; Cheetah Medical, Tel Aviv, Israel) for assessment of fluid responsiveness (FR) in spontaneously breathing emergency department (ED) patients. METHODS...

  11. Distributed propulsion.

    OpenAIRE

    Lindström, Robin; Rosvall, Tobias

    2013-01-01

    En prestandaanalys utfördes på en SAAB 2000 som referensobjekt. Olika metoder för att driva flygplan på ett miljövänligare sätt utvärderades tillsammans med distributed propulsion. Efter undersökningar valdes elmotorer tillsammans med Zink-luft batterier för att driva SAAB 2000 med distributed propulsion. En prestandaanalys utfördes på detta plan på samma sätt som för den ursprungliga SAAB 2000. Resultaten jämfördes och slutsatsen blev att räckvidden var för kort för att konfigurationen skull...

  12. Is there a best side for cochlear implants in post-lingual patients?

    Science.gov (United States)

    Amaral, Maria Stella Arantes do; Damico, Thiago A; Gonçales, Alina S; Reis, Ana C M B; Isaac, Myriam de Lima; Massuda, Eduardo T; Hyppolito, Miguel Angelo

    2017-07-29

    Cochlear Implant is a sensory prosthesis capable of restoring hearing in patients with severe or profound bilateral sensorineural hearing loss. To evaluate if there is a better side to be implanted in post-lingual patients. Retrospective longitudinal study. Participants were 40 subjects, of both sex, mean age of 47 years, with post-lingual hearing loss, users of unilateral cochlear implant for more than 12 months and less than 24 months, with asymmetric auditor reserve between the ears (difference of 10dBNA, In at least one of the frequencies with a response, between the ears), divided into two groups. Group A was composed of individuals with cochlear implant in the ear with better auditory reserve and Group B with auditory reserve lower in relation to the contralateral side. There was no statistical difference for the tonal auditory threshold before and after cochlear implant. A better speech perception in pre-cochlear implant tests was present in B (20%), but the final results are similar in both groups. The cochlear implant in the ear with the worst auditory residue favors a bimodal hearing, which would allow the binaural summation, without compromising the improvement of the audiometric threshold and the speech perception. Copyright © 2017 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  13. Vehicle with inclinable caterpillar propulsion units

    International Nuclear Information System (INIS)

    Clar, G.

    1991-01-01

    This vehicle usable in hostile environment such nuclear industry has four propulsion units with a caterpillar track and two integrated motors: one for advancing the caterpillar track and the other for inclining the propulsion unit when overcoming obstacles. Each propulsion unit is easily replaceable because there are no mechanical parts in the body of the vehicle [fr

  14. Urethral reconstruction with a 3D porous bacterial cellulose scaffold seeded with lingual keratinocytes in a rabbit model

    International Nuclear Information System (INIS)

    Huang, Jian-Wen; Lv, Xiang-Guo; Song, Lu-Jie; Feng, Chao; Xie, Min-Kai; Li, Chao; Li, Hong-Bin; Wang, Ji-Hong; Zhu, Wei-Dong; Xu, Yue-Min; Li, Zhe; Chen, Shi-Yan; Wang, Hua-Ping

    2015-01-01

    The goal of this study was to evaluate the effects of urethral reconstruction with a three-dimensional (3D) porous bacterial cellulose (BC) scaffold seeded with lingual keratinocytes in a rabbit model. A novel 3D porous BC scaffold was prepared by gelatin sponge interfering in the BC fermentation process. Rabbit lingual keratinocytes were isolated, expanded, and seeded onto 3D porous BC. BC alone (group 1, N  =  10), 3D porous BC alone (group 2, N  =  10), and 3D porous BC seeded with lingual keratinocytes (group 3, N  =  10) were used to repair rabbit ventral urethral defects (2.0   ×   0.8 cm). Scanning electron microscopy revealed that BC consisted of a compact laminate while 3D porous BC was composed of a porous sheet buttressed by a dense outer layer. The average pore diameter and porosity of the 3D porous BC were 4.23   ±   1.14 μm and 67.00   ±   6.80%, respectively. At 3 months postoperatively, macroscopic examinations and retrograde urethrograms of urethras revealed that all urethras maintained wide calibers in group 3. Strictures were found in all rabbits in groups 1 and 2. Histologically, at 1 month postoperatively, intact epithelium occurred in group 3, and discontinued epithelium was found in groups 1 and 2. However, groups 2 and 3 exhibited similar epithelial regeneration, which was superior to that of group 1 at 3 months (p  <  0.05). Comparisons of smooth muscle content and endothelia density among the three groups revealed a significant increase at each time point (p  <  0.05). Our results demonstrated that 3D porous BC seeded with lingual keratinocytes enhanced urethral tissue regeneration. 3D porous BC could potentially be used as an optimized scaffold for urethral reconstruction. (paper)

  15. Use of an automated bolus calculator in MDI-treated type 1 diabetes

    DEFF Research Database (Denmark)

    Schmidt, Signe; Meldgaard, Merete; Serifovski, Nermin

    2012-01-01

    To investigate the effect of flexible intensive insulin therapy (FIIT) and an automated bolus calculator (ABC) in a Danish type 1 diabetes population treated with multiple daily injections. Furthermore, to test the feasibility of teaching FIIT in a 3-h structured course....

  16. Lingual mandibular osteonecrosis after dental impressions for orthodontic study models.

    Science.gov (United States)

    Cerruto, Carmen; Ugolini, Alessandro; Cozzani, Mauro

    2018-03-01

    A 43-year-old man sought orthodontic treatment to close anterior diastemas. During the impression procedure for routine documentation, the orthodontic assistant exerted excessive pressure on the metallic tray; 2 days later, the patient reported the detachment of a small piece of mucosa overlying the mylohyoid crest and was referred to a maxillofacial surgeon with a diagnosis of lingual mandibular osteonecrosis. The etiology of bony osteonecrosis is discussed, together with the anatomic variations that can be present in the basal bone and that must be carefully checked before an impression is taken. Copyright © 2017 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  17. Distribution and mixing of a liquid bolus in pleural space.

    Science.gov (United States)

    Bodega, Francesca; Tresoldi, Claudio; Porta, Cristina; Zocchi, Luciano; Agostoni, Emilio

    2006-02-28

    Distribution and mixing time of boluses with labeled albumin in pleural space of anesthetized, supine rabbits were determined by sampling pleural liquid at different times in various intercostal spaces (ics), and in cranial and caudal mediastinum. During sampling, lung and chest wall were kept apposed by lung inflation. This was not necessary in costo-phrenic sinus. Here, 10 min after injection, lung inflation increased concentration of labeled albumin by 50%. Lung inflation probably displaces some pleural liquid cranio-caudally, increasing labeled albumin concentration caudally to injection point (6th ics), and decreasing it cranially. Boluses of 0.1-1 ml did not preferentially reach mediastinal regions, as maintained by others. Time for an approximate mixing was approximately 1 h for 0.1 ml, and approximately 30 min for 1 ml. This relatively long mixing time does not substantially affect determination of contribution of lymphatic drainage through stomata to overall removal of labeled albumin from 0.3 ml hydrothoraces lasting 3 h [Bodega, F., Agostoni, E., 2004. Contribution of lymphatic drainage through stomata to albumin removal from pleural space. Respir. Physiol. Neurobiol. 142, 251-263].

  18. Comparison of bolus versus fractionated oral applications of [13C]-linoleic acid in humans.

    Science.gov (United States)

    Demmelmair, H; Iser, B; Rauh-Pfeiffer, A; Koletzko, B

    1999-07-01

    The endogenous conversion of linoleic acid into long-chain polyunsaturated fatty acids is of potential importance for meeting substrate requirements, particularly in young infants. After application of [13C]-linoleic acid, we estimated its conversion to dihomo-gamma-linolenic and arachidonic acids from only two blood samples. Oral tracer doses were given to five healthy adults as a single bolus. In four subjects the tracer was given in nine equal portions over 3 days. Concentration and 13C content of fatty acids from serum phospholipids were analysed by gas chromatography combustion isotope ratio-mass spectrometry. Areas under the tracer-concentration curves were calculated, and fractional transfer and turnover rates estimated from compartmental models. The median fractional turnover of linoleic acid was 93.7% per day (interquartile range 25.3) in the bolus group and 80. 0% per day (6.3) in the fraction group (NS). Fractional conversion of linoleic to dihomo-gamma-linolenic acid was 1.5% (0.9) vs. 2.1% (0.7) (bolus vs. fraction, P /= 0.94, P < 0.05) with the ratio of areas under the curve. Using areas under the curve overestimates the conversion, because different residence times are not considered. Estimation of conversion intensity appears possible with only one blood sample obtained after tracer application.

  19. Kinematic Investigation of Lingual Movement in Words of Increasing Length in Acquired Apraxia of Speech

    Science.gov (United States)

    Bartle-Meyer, Carly J.; Goozee, Justine V.; Murdoch, Bruce E.

    2009-01-01

    The current study aimed to use electromagnetic articulography (EMA) to investigate the effect of increasing word length on lingual kinematics in acquired apraxia of speech (AOS). Tongue-tip and tongue-back movement was recorded for five speakers with AOS and a concomitant aphasia (mean age = 53.6 years; SD = 12.60) during target consonant…

  20. Distributed propulsion and future aerospace technologies

    OpenAIRE

    Ameyugo, Gregorio

    2007-01-01

    This thesis describes an Engineering Doctorate project in Distributed Propulsion carried out from 2004 to 2007 at Cranfield University. Distributed propulsion is a propulsion system arrangement that consists in spreading the engine thrust along the aircraft span. This can be accomplished by distributing a series of driven fans or the engines themselves. The aim of this project is to determine the feasibility of ...

  1. Baselines and test data for cross-lingual inference

    DEFF Research Database (Denmark)

    Agic, Zeljko; Schluter, Natalie

    2018-01-01

    The recent years have seen a revival of interest in textual entailment, sparked by i) the emergence of powerful deep neural network learners for natural language processing and ii) the timely development of large-scale evaluation datasets such as SNLI. Recast as natural language inference......, the problem now amounts to detecting the relation between pairs of statements: they either contradict or entail one another, or they are mutually neutral. Current research in natural language inference is effectively exclusive to English. In this paper, we propose to advance the research in SNLI-style natural...... language inference toward multilingual evaluation. To that end, we provide test data for four major languages: Arabic, French, Spanish, and Russian. We experiment with a set of baselines. Our systems are based on cross-lingual word embeddings and machine translation. While our best system scores an average...

  2. Open-loop glucose control: Automatic IOB-based super-bolus feature for commercial insulin pumps.

    Science.gov (United States)

    Rosales, Nicolás; De Battista, Hernán; Vehí, Josep; Garelli, Fabricio

    2018-06-01

    Although there has been significant progress towards closed-loop type 1 diabetes mellitus (T1DM) treatments, most diabetic patients still treat this metabolic disorder in an open-loop manner, based on insulin pump therapy (basal and bolus insulin infusion). This paper presents a method for automatic insulin bolus shaping based on insulin-on-board (IOB) as an alternative to conventional bolus dosing. The methodology presented allows the pump to generate the so-called super-bolus (SB) employing a two-compartment IOB dynamic model. The extra amount of insulin to boost the bolus and the basal cutoff time are computed using the duration of insulin action (DIA). In this way, the pump automatically re-establishes basal insulin when IOB reaches its basal level. Thus, detrimental transients caused by manual or a-priori computations are avoided. The potential of this method is illustrated via in-silico trials over a 30 patients cohort in single meal and single day scenarios. In the first ones, improvements were found (standard treatment vs. automatic SB) both in percentage time in euglycemia (75g meal: 81.9 ± 15.59 vs. 89.51 ± 11.95, ρ ≃ 0; 100g meal: 75.12 ± 18.23 vs. 85.46 ± 14.96, ρ ≃ 0) and time in hypoglecymia (75g meal: 5.92 ± 14.48 vs. 0.97 ± 4.15, ρ=0.008; 100g meal: 9.5 ± 17.02 vs. 1.85 ± 7.05, ρ=0.014). In a single day scenario, considering intra-patient variability, the time in hypoglycemia was reduced (9.57 ± 14.48 vs. 4.21 ± 6.18, ρ=0.028) and improved the time in euglycemia (79.46 ± 17.46 vs. 86.29 ± 11.73, ρ=0.007). The automatic IOB-based SB has the potential of a better performance in comparison with the standard treatment, particularly for high glycemic index meals with high carbohydrate content. Both glucose excursion and time spent in hypoglycemia were reduced. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. Enabling Electric Propulsion for Flight

    Science.gov (United States)

    Ginn, Starr Renee

    2015-01-01

    Team Seedling project AFRC and LaRC 31ft distributed electric propulsion wing on truck bed up 75 miles per hour for coefficient of lift validation. Convergent Aeronautic Solutions project, sub-project Convergent Electric Propulsion Technologies AFRC, LaRC and GRC, re-winging a 4 passenger Tecnam aircraft with a 31ft distributed electric propulsion wing. Advanced Air Transport Technologies (Fixed Wing), Hybrid Electric Research Theme, developing a series hybrid ironbird and flight sim to study integration and performance challenges in preparation for a 1-2 MW flight project.

  4. Feasibility of test-bolus DCE-MRI using CAIPIRINHA-VIBE for the evaluation of pancreatic malignancies

    Energy Technology Data Exchange (ETDEWEB)

    Huh, Jimi; Seo, Nieun; Kim, Bohyun [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center, 88 Olympic-ro 43-gil, Songpa-gu, Seoul (Korea, Republic of); Choi, Yoonseok; Woo, Dong-Cheol; Lee, Chang Kyung [Asan Medical Center, Bioimaging Center, Asan Institute for Life Sciences, Seoul (Korea, Republic of); Kim, In Seong [Siemens Healthcare, Seoul (Korea, Republic of); Nickel, Dominik [Siemens Healthcare, Erlangen (Germany); Kim, Kyung Won [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center, 88 Olympic-ro 43-gil, Songpa-gu, Seoul (Korea, Republic of); Asan Medical Center, Bioimaging Center, Asan Institute for Life Sciences, Seoul (Korea, Republic of)

    2016-11-15

    To evaluate the feasibility of test-bolus dynamic contrast-enhanced (DCE) MRI with CAIPIRINHA-VIBE for pancreatic malignancies. Thirty-two patients underwent DCE-MRI with CAIPIRINHA-VIBE after injection of 2 mL gadolinium. From the resulting time-intensity curve (TIC), we estimated the arterial (AP) and portal venous phase (PVP) scan timing for subsequent multiphasic MRI. DCE-MRI perfusion maps were generated, and perfusion parameters were calculated. The image quality was rated on a 5-point scale (1: poor, 5: excellent). Goodness-of-fit of the TIC was evaluated by Pearson's χ{sup 2} test. Test-bolus DCE-MRIs with high temporal (3 s) and spatial resolution (1 x 1 x 4 mm{sup 3}) were acquired with good-quality perfusion maps of Ktrans and iAUC (mean score 4.313 ± 0.535 and 4.125 ± 0.554, respectively). The mean χ{sup 2} values for fitted TICs were 0.115 ± 0.082 for the pancreatic parenchyma and 0.784 ± 0.074 for pancreatic malignancies, indicating an acceptable goodness-of-fit. Test-bolus DCE-MRI was highly accurate in estimating the proper timing of AP (90.6 %) and PVP (100 %) of subsequent multiphasic MRI. Between pancreatic adenocarcinomas and neuroendocrine tumours, there were significant differences in the Ktrans (0.073 ± 0.058 vs. 0.308 ± 0.062, respectively; p = 0.007) and iAUC (1.501 ± 0.828 vs. 3.378 ± 0.378, respectively; p = 0.045). Test-bolus DCE-MRI using CAIPIRINHA-VIBE is feasible for incorporating perfusion analysis of pancreatic tumours into routine multiphasic MRI. (orig.)

  5. Dextrose boluses versus burette dextrose infusions in prevention of hypoglycemia among preterms admitted at Mulago Hospital: an open label randomized clinical trial.

    Science.gov (United States)

    Kutamba, E; Lubega, S; Mugalu, J; Ouma, J; Mupere, E

    2014-09-01

    Hypoglycemia is a major cause of morbidity and mortality among preterm infants and its management remains a challenge in resource limited settings. Use of dextrose infusion by the recommended infusion pumps is not feasible in our environment due to their high costs and yet the current use of mini dextrose boluses with syringes as adapted at Mulago national referral and tertiary teaching hospital has unknown efficacy in prevention of hypoglycemia. We determined the efficacy of dextrose infusions by burettes versus two hourly dextrose boluses in prevention of hypoglycemia among preterms admitted in the first 72 hours at Special Care Unit, Mulago Hospital. One hundred and forty preterms aged 0 to 24 hours of life were randomized to receive 10% IV dextrose either as mini boluses or by infusion using burettes in an open label clinical trial. Blood glucose was measured at 0, two hourly for next 6 hours, 6 hourly for next 12 hours and thereafter 12 hourly until end of 72 hours following admission. Primary end point was incidence of hypoglycemia (random blood sugar (RBS) dextrose infusion was computed using 1-RR. From February 2012 to April 2012, 68 preterms in the bolus arm and 72 in the infusion arm were studied. Hypoglycemia was detected in 34% (48/140). The incidence of hypoglycemia in the bolus arm was 59% (40/68) compared to 11% (8/72) in the infusion arm (RR; 0.19, 95% CI; 0.09-0.37). Efficacy (1-RR) of infusion by burettes versus boluses in prevention of hypoglycemia among preterms was 0.81 (95% CI; 0.63-0.90). Continuous 10% dextrose infusion by burettes reduced the incidence of hypoglycemia by 81% in the first 72 hours of admission compared to two hourly 10% mini dextrose boluses among preterms admitted at Special Care Unit, Mulago Hospital. (ClinicalTrials.gov Identifier: NCT01688674).

  6. Aeroelastic Wing Shaping Using Distributed Propulsion

    Science.gov (United States)

    Nguyen, Nhan T. (Inventor); Reynolds, Kevin Wayne (Inventor); Ting, Eric B. (Inventor)

    2017-01-01

    An aircraft has wings configured to twist during flight. Inboard and outboard propulsion devices, such as turbofans or other propulsors, are connected to each wing, and are spaced along the wing span. A flight controller independently controls thrust of the inboard and outboard propulsion devices to significantly change flight dynamics, including changing thrust of outboard propulsion devices to twist the wing, and to differentially apply thrust on each wing to change yaw and other aspects of the aircraft during various stages of a flight mission. One or more generators can be positioned upon the wing to provide power for propulsion devices on the same wing, and on an opposite wing.

  7. Visions of the Future: Hybrid Electric Aircraft Propulsion

    Science.gov (United States)

    Bowman, Cheryl L.

    2016-01-01

    The National Aeronautics and Space Administration (NASA) is investing continually in improving civil aviation. Hybridization of aircraft propulsion is one aspect of a technology suite which will transform future aircraft. In this context, hybrid propulsion is considered a combination of traditional gas turbine propulsion and electric drive enabled propulsion. This technology suite includes elements of propulsion and airframe integration, parallel hybrid shaft power, turbo-electric generation, electric drive systems, component development, materials development and system integration at multiple levels.

  8. MW-Class Electric Propulsion System Designs

    Science.gov (United States)

    LaPointe, Michael R.; Oleson, Steven; Pencil, Eric; Mercer, Carolyn; Distefano, Salvador

    2011-01-01

    Electric propulsion systems are well developed and have been in commercial use for several years. Ion and Hall thrusters have propelled robotic spacecraft to encounters with asteroids, the Moon, and minor planetary bodies within the solar system, while higher power systems are being considered to support even more demanding future space science and exploration missions. Such missions may include orbit raising and station-keeping for large platforms, robotic and human missions to near earth asteroids, cargo transport for sustained lunar or Mars exploration, and at very high-power, fast piloted missions to Mars and the outer planets. The Advanced In-Space Propulsion Project, High Efficiency Space Power Systems Project, and High Power Electric Propulsion Demonstration Project were established within the NASA Exploration Technology Development and Demonstration Program to develop and advance the fundamental technologies required for these long-range, future exploration missions. Under the auspices of the High Efficiency Space Power Systems Project, and supported by the Advanced In-Space Propulsion and High Power Electric Propulsion Projects, the COMPASS design team at the NASA Glenn Research Center performed multiple parametric design analyses to determine solar and nuclear electric power technology requirements for representative 300-kW class and pulsed and steady-state MW-class electric propulsion systems. This paper describes the results of the MW-class electric power and propulsion design analysis. Starting with the representative MW-class vehicle configurations, and using design reference missions bounded by launch dates, several power system technology improvements were introduced into the parametric COMPASS simulations to determine the potential system level benefits such technologies might provide. Those technologies providing quantitative system level benefits were then assessed for technical feasibility, cost, and time to develop. Key assumptions and primary

  9. Comparison of Power Versus Manual Injection in Bolus Shape and Image Quality on Contrast-Enhanced Magnetic Resonance Angiography: An Experimental Study in a Swine Model.

    Science.gov (United States)

    Tsuboyama, Takahiro; Jost, Gregor; Pietsch, Hubertus; Tomiyama, Noriyuki

    2017-09-01

    The aim of this study was to compare power versus manual injection in bolus shape and image quality on contrast-enhanced magnetic resonance angiography (CE-MRA). Three types of CE-MRA (head-neck 3-dimensional [3D] MRA with a test-bolus technique, thoracic-abdominal 3D MRA with a bolus-tracking technique, and thoracic-abdominal time-resolved 4-dimensional [4D] MRA) were performed after power and manual injection of gadobutrol (0.1 mmol/kg) at 2 mL/s in 12 pigs (6 sets of power and manual injections for each type of CE-MRA). For the quantitative analysis, the signal-to-noise ratio was measured on ascending aorta, descending aorta, brachiocephalic trunk, common carotid artery, and external carotid artery on the 6 sets of head-neck 3D MRA, and on ascending aorta, descending aorta, brachiocephalic trunk, abdominal aorta, celiac trunk, and renal artery on the 6 sets of thoracic-abdominal 3D MRA. Bolus shapes were evaluated on the 6 sets each of test-bolus scans and 4D MRA. For the qualitative analysis, arterial enhancement, superimposition of nontargeted enhancement, and overall image quality were evaluated on 3D MRA. Visibility of bolus transition was assessed on 4D MRA. Intraindividual comparison between power and manual injection was made by paired t test, Wilcoxon rank sum test, and analysis of variance by ranks. Signal-to-noise ratio on 3D MRA was statistically higher with power injection than with manual injection (P < 0.001). Bolus shapes (test-bolus, 4D MRA) were represented by a characteristic standard bolus curve (sharp first-pass peak followed by a gentle recirculation peak) in all the 12 scans with power injection, but only in 1 of the 12 scans with manual injection. Standard deviations of time-to-peak enhancement were smaller in power injection than in manual injection. Qualitatively, although both injection methods achieved diagnostic quality on 3D MRA, power injection exhibited significantly higher image quality than manual injection (P = 0.001) due to

  10. Bolus and continuous infusion mitoxantrone in newly diagnosed adult acute lymphoblastic leukemia: results of two consecutive phase II clinical studies.

    Science.gov (United States)

    Koc, Y; Akpek, G; Kansu, E; Kars, A; Tekuzman, G; Baltali, E; Güler, N; Barista, I; Güllü, I; Ozisik, Y; Firat, D

    1998-01-01

    Two consecutive phase II clinical studies were designed to evaluate the efficacy and safety of bolus and continuous infusion (CI) mitoxantrone (MTZ) in 39 patients with newly diagnosed acute lymphocytic leukemia (ALL). MTZ was used as part of the classical ALL induction regimen. Twenty patients were treated with bolus MTZ (10 mg/m2 for 3 days) combined with vincristine and prednisone. The same regimen was given to a second set of 19 patients, except that MTZ was administered as a 24-hr CI. Both groups received bimonthly intensifications with vincristine and prednisone for 3 years, along with oral maintenance therapy. Patients in the CI-MTZ study arm received additional MTZ on the first day of intensification cycles. Seventeen patients (85%) in the bolus arm and 15 patients (79%) in the CI arm achieved complete remission (CR). Median disease-free survivals (DFS) in the bolus and CI groups were 11 and 15 months after median follow-ups of 16 (3.5-96) and 13 (2.3-32) months, respectively. At 2.5 years, DFS rates were 29.4% and 34.4% in the bolus and CI groups (p > 0.05). There were no significant differences between two groups in rates of early death, degree of organ toxicity, or duration of neutropenia and thrombocytopenia. Significant cardiac toxicity was not observed in either group. Bolus or CI administration of MTZ was equally effective and was well tolerated. Neither the mode of administration nor increasing the dose intensity of MTZ by incorporating intensification cycles reduced relapse rates. Development of new antileukemia agents and novel treatment approaches are still needed to improve the high relapse rates in adult ALL once a complete response is achieved.

  11. Factors Influencing ACT After Intravenous Bolus Administration of 100 IU/kg of Unfractionated Heparin During Cardiac Catheterization in Children.

    Science.gov (United States)

    Muster, Ileana; Haas, Thorsten; Quandt, Daniel; Kretschmar, Oliver; Knirsch, Walter

    2017-10-01

    Anticoagulation using intravenous bolus administration of unfractionated heparin (UFH) aims to prevent thromboembolic complications in children undergoing cardiac catheterization (CC). Optimal UFH dosage is needed to reduce bleeding complications. We analyzed the effect of bolus UFH on activated clotting time (ACT) in children undergoing CC focusing on age-dependent, anesthesia-related, or disease-related influencing factors. This retrospective single-center study of 183 pediatric patients receiving UFH during CC analyzed ACT measured at the end of CC. After bolus administration of 100 IU UFH/kg body weight, ACT values between 105 and 488 seconds were reached. Seventy-two percent were within target level of 160 to 240 seconds. Age-dependent differences were not obtained ( P = .407). The ACT values were lower due to hemodilution (total fluid and crystalloid administration during CC, both P ACT values but occurred more frequently in children between 1 month and 1 year of age (91%). In conclusion, with a bolus of 100 IU UFH/kg, an ACT target level of 160 to 240 seconds can be achieved during CC in children in 72%, which is influenced by hemodilution and anticoagulant and antiplatelet premedication but not by age.

  12. [Observing the density increase curve after intravenous contrast medium administration using a bolus triggering system: a method for detection cardiovascular disorders?].

    Science.gov (United States)

    Stückle, C A; Kickuth, R; Kirchner, E M; Liermann, D; Kirchner, J

    2002-06-01

    Recently bolus tracking systems were developed to improve the timing of intravenous contrast media application in helical computed tomography. We investigated the benefit of this new method as a parameter of the cardiac function. Retrospective analysis of 64 patients which incidentally underwent bolus triggered contrast enhanced helical CT and invasive investigation of the heart within one week. All examinations were performed on the CT scanner Somatom Plus 4 Volume Zoom (Siemens Corp., Forchheim, Germany) using the C.A.R.E. Bolus software. This performs repetitive low-dose test scans (e.g. for the abdomen: 140 kV, 20 mA, Tl 0.5 s) and measures the Hounsfield attenuation (increase over the baseline) in a preselected region of interest. The displayed increase of vascular density over the time after peripheral contrast media injection (75 ml lopromid (300 mg/ml), 2 ml/s) was categorised to three types: (a) rapid increase, (b) deceleration before a 100 HE threshold was reached and (c) one or more peaks. The findings of the invasive investigation of the heart were correlated to the findings of the bolus-tracking measurements. The examinations were categorized as follows: 19 type A, 34 type B, 11 type C. We found a high significant correlation between the type of the Hounsfield attenuation and systolic pressure in the left ventricle. There was no correlation between the type of the Hounsfield attenuation and the diastolic pressure in the left ventricle, the pressures related to the right ventricle or the ejection fraction. The bolus-tacking system showed a sensitivity of 53, a specificity of 82, an accuracy of 70%, a positive predictive value of 70% and a negative predictive value of 70% in detection of left heart failure. The bolus tracking system C.A.R.E.-bolus often shows atypical Hounsfield attenuation in cases of cardiac failure but is not suitable as a screening method of the cardiopulmonary function.

  13. Functional and comparative study of lingual papillae in four species of bear (Ursidae) by scanning electron microscopy.

    Science.gov (United States)

    Pastor, J F; Barbosa, M; de Paz, F J; García, M; Ferrero, E

    2011-10-01

    The eight current species of bear (Ursidae) are widely distributed throughout Europe, Asia, and America. They are mainly encountered in the northern hemisphere, except for the spectacled bear and the sun bear, which are also found in the south of the equator. Adaptations of the masticatory apparatus (teeth, tongue, and musculature) to diet are one of the factors that imply the greatest structural changes in the cranium. This diet may be carnivorous, herbivorous, melliferous, or insectivorous, with one type of food predominating according to the time of year. The way in which food is eaten determines the morphology of the lingual surface; generally speaking, all bears put their mouth to the food, which, initially, they lick or they let the food stick to their tongue, as occurs when insects are eaten. As in all mammals, a distinction can be made between mechanical and gustatory papillae and the development and distribution of which depend on the species and their eating habits. In this study of the complete tongues of four species of adult bears, we describe the morphology of the lingual surfaces, the different types of papillae, their characteristics, and topographic distribution. It was seen that there were five main types of lingual papillae: filiform, conical, fungiform, foliate, and vallate. Morphology of the microgrooves and pores was similar to that observed in other mammals. In general, there were no great differences among the four species of bears studied, perhaps due to the similarity in the kind of food they consume in captivity. Copyright © 2011 Wiley-Liss, Inc.

  14. The Space Nuclear Thermal Propulsion Program: Propulsion for the twenty first century

    International Nuclear Information System (INIS)

    Bleeker, G.; Moody, J.; Kesaree, M.

    1993-01-01

    As mission requirements approach the limits of the chemical propulsion systems, new engines must be investigated that can meet the advanced mission requirements of higher payload fractions, higher velocities, and consequently higher specific Impulses (Isp). The propulsion system that can meet these high demands is a nuclear thermal rocket engine. This engine generates the thrust by expanding/existing the hydrogen, heated from the energy derived from the fission process in a reactor, through a nozzle. The Department of Defense (DoD), however, initiated a new nuclear rocket development program in 1987 for ballistic missile defense application. The Space Nuclear Thermal Propulsion (SNTP) Program that seeks to improve on the technology of ROVER/NERVA grew out of this beginning and has been managed by the Air Force, with the involvement of DoE and NASA. The goal of the SNTP Program is to develop an engine to meet potential Air Force requirements for upper stage engine, bimodal propulsion/power applications, and orbital transfer vehicles, as well as the NASA requirements for possible missions to the Moon and Mars. During the entire life of the program, the DoD has considered safety to be of paramount importance, and is following all national environmental policies

  15. The comparison of bolus tracking and test bolus techniques for computed tomography thoracic angiography in healthy beagles

    Directory of Open Access Journals (Sweden)

    Nicolette Cassel

    2013-05-01

    Full Text Available Computed tomography thoracic angiography studies were performed on five adult beagles using the bolus tracking (BT technique and the test bolus (TB technique, which were performed at least two weeks apart. For the BT technique, 2 mL/kg of 300 mgI/mL iodinated contrast agent was injected intravenously. Scans were initiated when the contrast in the aorta reached 150 Hounsfield units (HU. For the TB technique, the dogs received a test dose of 15% of 2 mL/kg of 300 mgI/mL iodinated contrast agent, followed by a series of low dose sequential scans. The full dose of the contrast agent was then administered and the scans were conducted at optimal times as identified from time attenuation curves. Mean attenuation in HU was measured in the aorta (Ao and right caudal pulmonary artery (rCPA. Additional observations included the study duration, milliAmpere (mA, computed tomography dose index volume (CTDI[vol] and dose length product (DLP. The attenuation in the Ao (BT = 660 52 HU ± 138 49 HU, TB = 469 82 HU ± 199 52 HU, p = 0.13 and in the rCPA (BT = 606 34 HU ± 143 37 HU, TB = 413 72 HU ± 174.99 HU, p = 0.28 did not differ significantly between the two techniques. The BT technique was conducted in a significantly shorter time period than the TB technique (p = 0.03. The mean mA for the BT technique was significantly lower than the TB technique (p = 0.03, as was the mean CTDI(vol (p = 0.001. The mean DLP did not differ significantly between the two techniques (p = 0.17. No preference was given to either technique when evaluating the Ao or rCPA but the BT technique was shown to be shorter in duration and resulted in less DLP than the TB technique.

  16. Multi-Lingual and Multi-Cultural Aspects of Post-Disaster Emergency Communication

    DEFF Research Database (Denmark)

    Selsøe Sørensen, Henrik

    2014-01-01

    recent technological advances and the upcoming of social media as well as intelligent and instant big-data analyses since the reported research was carried out, it is suggested that the original ideas be revisited and re-engineered in view of improving efficiency in cross-frontier post-disaster emergency......LinguaNet® is a system for fast multi-lingual communications between police forces co-operating across frontiers. It has been in operation for more than two decades and proved its worth. From 1995 to 1998, CBS developed a number of add-ons to the system in the framework of an EU project in order...

  17. Materials Advance Chemical Propulsion Technology

    Science.gov (United States)

    2012-01-01

    In the future, the Planetary Science Division of NASA's Science Mission Directorate hopes to use better-performing and lower-cost propulsion systems to send rovers, probes, and observers to places like Mars, Jupiter, and Saturn. For such purposes, a new propulsion technology called the Advanced Materials Bipropellant Rocket (AMBR) was developed under NASA's In-Space Propulsion Technology (ISPT) project, located at Glenn Research Center. As an advanced chemical propulsion system, AMBR uses nitrogen tetroxide oxidizer and hydrazine fuel to propel a spacecraft. Based on current research and development efforts, the technology shows great promise for increasing engine operation and engine lifespan, as well as lowering manufacturing costs. In developing AMBR, ISPT has several goals: to decrease the time it takes for a spacecraft to travel to its destination, reduce the cost of making the propulsion system, and lessen the weight of the propulsion system. If goals like these are met, it could result in greater capabilities for in-space science investigations. For example, if the amount (and weight) of propellant required on a spacecraft is reduced, more scientific instruments (and weight) could be added to the spacecraft. To achieve AMBR s maximum potential performance, the engine needed to be capable of operating at extremely high temperatures and pressure. To this end, ISPT required engine chambers made of iridium-coated rhenium (strong, high-temperature metallic elements) that allowed operation at temperatures close to 4,000 F. In addition, ISPT needed an advanced manufacturing technique for better coating methods to increase the strength of the engine chamber without increasing the costs of fabricating the chamber.

  18. Powered Flight The Engineering of Aerospace Propulsion

    CERN Document Server

    Greatrix, David R

    2012-01-01

    Whilst most contemporary books in the aerospace propulsion field are dedicated primarily to gas turbine engines, there is often little or no coverage of other propulsion systems and devices such as propeller and helicopter rotors or detailed attention to rocket engines. By taking a wider viewpoint, Powered Flight - The Engineering of Aerospace Propulsion aims to provide a broader context, allowing observations and comparisons to be made across systems that are overlooked by focusing on a single aspect alone. The physics and history of aerospace propulsion are built on step-by-step, coupled with the development of an appreciation for the mathematics involved in the science and engineering of propulsion. Combining the author’s experience as a researcher, an industry professional and a lecturer in graduate and undergraduate aerospace engineering, Powered Flight - The Engineering of Aerospace Propulsion covers its subject matter both theoretically and with an awareness of the practicalities of the industry. To ...

  19. Effects of labial and lingual retraction and intrusion force on maxillary central incisor with varying collum angles: A three-dimensional finite elemental analysis

    Directory of Open Access Journals (Sweden)

    Sandesh S Pai

    2017-01-01

    Full Text Available Aims: This study aims to analyze the effects of intrusive force, retraction force, and torque control on the maxillary central incisors with varying degrees of collum angle in labial and lingual orthodontic treatment procedures using finite element analysis. Subjects and Methods: Four pairs of three-dimensional finite element models (FEMs representative of maxillary central incisor with periodontal ligament (PDL and alveolar bone were constructed using ANSYS software (version 5.4, ANSYS Inc., Canonsburg, PA, USA. The models with 0°, 5°, 10°, and 15° were created based on crown root angulation. Four models for labial and four models for lingual orthodontic procedure were constructed. Each model was subjected to three forces, i.e., retraction force of 1 N, lingual root torque of −5 × 10−3 N and intrusive force of 0.64 N on crown with labially and lingually positioned brackets. Principal stress and strain, center of rotation and root apex displacement were monitored. Statistical Analysis Used: Not required (FEM study. Results: With the increase in collum angle, the stress-strain distribution in PDL was increased in both labial orthodontics (LaO and lingual orthodontics (LiO. Stress-strain distribution in the PDL with LiO was more in all the models as compared to LaO. There was more of tipping movement as collum angle increased from 0° to 15° in both LaO and LiO. The amount of intrusion reduced as the collum angle increased in both the systems. However, more of intrusion was seen in LaO. With increase in collum angle, the center of rotation moved cervically in both the systems. Conclusions: From the present study, we conclude that as the collum angle increased, the stress-strain distribution increased in LaO and LiO. The center of rotation shifted cervically, and the intrusion decreased when collum angle increased. The values were more marked in LiO.

  20. Advanced Chemical Propulsion Study

    Science.gov (United States)

    Woodcock, Gordon; Byers, Dave; Alexander, Leslie A.; Krebsbach, Al

    2004-01-01

    A study was performed of advanced chemical propulsion technology application to space science (Code S) missions. The purpose was to begin the process of selecting chemical propulsion technology advancement activities that would provide greatest benefits to Code S missions. Several missions were selected from Code S planning data, and a range of advanced chemical propulsion options was analyzed to assess capabilities and benefits re these missions. Selected beneficial applications were found for higher-performing bipropellants, gelled propellants, and cryogenic propellants. Technology advancement recommendations included cryocoolers and small turbopump engines for cryogenic propellants; space storable propellants such as LOX-hydrazine; and advanced monopropellants. It was noted that fluorine-bearing oxidizers offer performance gains over more benign oxidizers. Potential benefits were observed for gelled propellants that could be allowed to freeze, then thawed for use.

  1. The prognostic value of histopathology on lingual nerve neurosensory recovery after micro-neurosurgery

    DEFF Research Database (Denmark)

    Hørberg, Mette; Reibel, Jesper; Kragelund, Camilla

    2016-01-01

    OBJECTIVE: Micro-neurosurgical repair is considered in permanent nerve damage but the outcome is unpredictable. We examined if histopathologic parameters of traumatic neuromas have a prognostic value for recovery in relation to lingual nerve micro-neurosurgery. MATERIALS AND METHODS: Retrospective...... case study on neurosensory recovery after micro-neurosurgery. Outcome variables were as follows: pain perception, two-point discrimination, and sum score of perception, before and 12 months after micro-neurosurgery. Predictive histopathology variables included size, nerve tissue, and inflammation...

  2. Scanning Electron Microscopic Study of the Lingual Papillae in the Anatolian Water Buffalo

    OpenAIRE

    Can, M; Atalgin, S. H

    2015-01-01

    The purpose of this study was to describe the surface structure of the lingual papillae in Anatolian Water Buffaloes using SEM. Six male Anatolian Water Buffaloes were used. Filiform, lentiform and conical papillae were determined three types as mechanical papillae. Fungiform and vallate papillae were observed two types as gustatory papillae on the tongue in Anatolian Water Buffalo. The filiform papillae were observed on the apex and body of the tongue, besides randomly identified lateral sur...

  3. In-Space Propulsion (346620) Technology Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Technologies include, but are not limited to, electric and advanced chemical propulsion, propellantless propulsion such as aerocapture and solar sails, sample return...

  4. Galvanic coupling of steel and gold alloy lingual brackets with orthodontic wires.

    Science.gov (United States)

    Polychronis, Georgios; Al Jabbari, Youssef S; Eliades, Theodore; Zinelis, Spiros

    2018-03-06

    The aim of this research was to assess galvanic behavior of lingual orthodontic brackets coupled with representative types of orthodontic wires. Three types of lingual brackets: Incognito (INC), In-Ovation L (IOV), and STb (STB) were combined with a stainless steel (SS) and a nickel-titanium (NiTi) orthodontic archwire. All materials were initially investigated by scanning electron microscopy / x-ray energy dispersive spectroscopy (SEM/EDX) while wires were also tested by x-ray diffraction spectroscopy (XRD). All bracket-wire combinations were immersed in acidic 0.1M NaCl 0.1M lactic acid and neutral NaF 0.3% (wt) electrolyte, and the potential differences were continuously recorded for 48 hours. The SEM/EDX analysis revealed that INC is a single-unit bracket made of a high gold (Au) alloy while IOV and STB are two-piece appliances in which the base and wing are made of SS alloys. The SS wire demonstrated austenite and martensite iron phase, while NiTi wire illustrated an intense austenite crystallographic structure with limited martensite. All bracket wire combinations showed potential differences below the threshold of galvanic corrosion (200 mV) except for INC and STB coupled with NiTi wire in NaF media. The electrochemical results indicate that all brackets tested demonstrated galvanic compatibility with SS wire, but fluoride treatment should be used cautiously with NiTi wires coupled with Au and SS brackets.

  5. Precision flow-controlled rubidium-82 generator for bolus and constant infusion studies

    International Nuclear Information System (INIS)

    Yano, Y.

    1981-01-01

    A unique flow rate controller and large reservoir pumping system have been developed for infusing rubidium-82 intravenously at bolus, constant, or variable infusion rates. Using rubidium-82 and the positron ring detector tomograph, extraction or flow information can be obtained in studies of the heart, head, or kidneys

  6. Adductor Canal Block With Continuous Infusion Versus Intermittent Boluses and Morphine Consumption

    DEFF Research Database (Denmark)

    Jaeger, Pia; Baggesgaard, Jonas; Sørensen, Johan K

    2018-01-01

    a randomized, blinded, controlled study, including patients scheduled for total knee arthroplasty with spinal anesthesia. Patients received 0.2% ropivacaine via a catheter in the adductor canal administered as either repeated intermittent boluses (21 mL/3 h) or continuous infusion (7 mL/h). The primary outcome...

  7. A Conceptual Tree of Laser Propulsion

    International Nuclear Information System (INIS)

    Pakhomov, Andrew V.; Sinko, John E.

    2008-01-01

    An original attempt to develop a conceptual tree for laser propulsion is offered. The tree provides a systematic view for practically all possible laser propulsion concepts and all inter-conceptual links, based on propellant phases and phase transfers. It also helps to see which fields of laser propulsion have been already thoroughly explored, where the next effort must be applied, and which paths should be taken with proper care or avoided entirely

  8. Use of 3D printers to create a patient‐specific 3D bolus for external beam therapy

    Science.gov (United States)

    Baker, Jamie; Hsia, An Ting; Xu, Zhigang

    2015-01-01

    The purpose of this paper is to demonstrate that an inexpensive 3D printer can be used to manufacture patient‐specific bolus for external beam therapy, and to show we can accurately model this printed bolus in our treatment planning system for accurate treatment delivery. Percent depth‐dose measurements and tissue maximum ratios were used to determine the characteristics of the printing materials, acrylonitrile butadiene styrene and polylactic acid, as bolus material with physical density of 1.04 and 1.2 g/cm3, and electron density of 3.38×1023electrons/cm3 and 3.80×1023 electrons/cm3, respectively. Dose plane comparisons using Gafchromic EBT2 film and the RANDO phantom were used to verify accurate treatment planning. We accurately modeled a printing material in Eclipse treatment planning system, assigning it a Hounsfield unit of 260. We were also able to verify accurate treatment planning using gamma analysis for dose plane comparisons. With gamma criteria of 5% dose difference and 2 mm DTA, we were able to have 86.5% points passing, and with gamma criteria of 5% dose difference and 3 mm DTA, we were able to have 95% points passing. We were able to create a patient‐specific bolus using an inexpensive 3D printer and model it in our treatment planning system for accurate treatment delivery. PACS numbers: 87.53.Jw, 87.53.Kn, 87.56.ng PMID:26103485

  9. Powersail High Power Propulsion System Design Study

    Science.gov (United States)

    Gulczinski, Frank S., III

    2000-11-01

    A desire by the United States Air Force to exploit the space environment has led to a need for increased on-orbit electrical power availability. To enable this, the Air Force Research Laboratory Space Vehicles Directorate (AFRL/ VS) is developing Powersail: a two-phased program to demonstrate high power (100 kW to 1 MW) capability in space using a deployable, flexible solar array connected to the host spacecraft using a slack umbilical. The first phase will be a proof-of-concept demonstration at 50 kW, followed by the second phase, an operational system at full power. In support of this program, the AFRL propulsion Directorate's Spacecraft Propulsion Branch (AFRL/PRS ) at Edwards AFB has commissioned a design study of the Powersail High Power Propulsion System. The purpose of this study, the results of which are summarized in this paper, is to perform mission and design trades to identify potential full-power applications (both near-Earth and interplanetary) and the corresponding propulsion system requirements and design. The design study shall farther identify a suitable low power demonstration flight that maximizes risk reduction for the fully operational system. This propulsion system is expected to be threefold: (1) primary propulsion for moving the entire vehicle, (2) a propulsion unit that maintains the solar array position relative to the host spacecraft, and (3) control propulsion for maintaining proper orientation for the flexible solar array.

  10. Tolerance to continuous intrathecal baclofen infusion can be reversed by pulsatile bolus infusion

    NARCIS (Netherlands)

    Heetla, H. W.; Staal, M. J.; van Laar, T.

    Study design: Pilot study. Objective: To study the effect of pulsatile bolus infusion of intrathecal baclofen (ITB) on daily ITB dose, in patients showing dose increases, probably due to tolerance. Setting: Department of neurology and neurosurgery, University Medical Center Groningen, the

  11. Lingual Thyroid Excision with Transoral Robotic Surgery

    Directory of Open Access Journals (Sweden)

    Elif Ersoy Callıoglu

    2015-01-01

    Full Text Available Ectopic thyroid gland may be detected at any place between foramen caecaum and normal thyroid localization due to inadequacy of the embryological migration of the thyroid gland. It has a prevalence varying between 1/10.000 and 1/100000 in the community. Usually follow-up without treatment is preferred except for obstructive symptoms, bleeding, and suspicion of malignity. Main symptoms are dysphagia, dysphonia, bleeding, dyspnea, and obstructive sleep apnea. In symptomatic cases, the first described method in surgical treatment is open approach since it is a region difficult to have access to. However, this approach has an increased risk of morbidity and postoperative complications. Transoral robotic surgery, which is a minimally invasive surgical procedure, has advantages such as larger three-dimensional point of view and ease of manipulation due to robotic instruments. In this report, a case at the age of 49 who presented to our clinic with obstructive symptoms increasing within the last year and was found to have lingual thyroid and underwent excision of ectopic thyroid tissue by da Vinci surgical system is presented.

  12. SU-F-T-86: Electron Dosimetric Effects of Bolus and Lens Shielding in Treating Superficial Eye Lesions

    Energy Technology Data Exchange (ETDEWEB)

    Young, L [University of Washington Medical Center, Seattle, WA (United States); Wootton, L [University of Washington School of Medicine, Seattle, WA (United States); Gopan, O; Liao, J [University of Washington, Seattle, WA (United States)

    2016-06-15

    Purpose: Electron therapy for the treatment of ocular lymphomas requires the lens to be shielded to prevent secondary cataracts. This work evaluates the dosimetry under a suspended eyeshield with and without bolus for low energy electron fields. Methods: Film (GafChromic EBT3) dosimetry and relative output factors were measured for 6, 8, and 10 MeV electron energies. A customized 5 cm diameter circle electron orbital cutout was constructed for a 6×6 cm applicator with a lens shield, 1 cm diameter Cerrobend cylinder with 2.2 cm length, suspended from an XV film covering the open field. Relative output factors were measured using a Scanditronix electron diode in a solid water phantom. Depth dose profiles were collected for bolus thicknesses of 0, 3, and 5 mm in solid water at a source to surface distance (SSD) of 100 cm. These measurements were repeated in a Rando phantom. Results: At 5 mm, the approximate distance of the lens from the surface of the cornea, the estimated dose in solid water under the suspended lens shield was reduced to 16%, 14%, and 13% of the unblocked dose at the same depth, for electron energies of 6, 8, and 10 MeV, respectively. Applying bolus increased estimated doses under the block to 22% for 3-mm and 32% for 5-mm thicknesses for a 6 MeV incident electron beam. This effect is reduced for higher energies where the corresponding values were 15.5% and 18% for 3-mm and 5-mm for an 8 MeV electron beam. Conclusion: The application of bolus to treat superficial eye lesions of the conjunctiva increases lens dose at a depth of 5-mm under the shielding block with decreasing electron energy. Careful selection of electron energy is needed to account for electron scatter under the lens shield with the application of bolus in order to prevent cataracts.

  13. Optimization of extended propulsion time nuclear-electric propulsion trajectories

    Science.gov (United States)

    Sauer, C. G., Jr.

    1981-01-01

    This paper presents the methodology used in optimizing extended propulsion time NEP missions considering realistic thruster lifetime constraints. These missions consist of a powered spiral escape from a 700-km circular orbit at the earth, followed by a powered heliocentric transfer with an optimized coast phase, and terminating in a spiral capture phase at the target planet. This analysis is most applicable to those missions with very high energy requirements such as outer planet orbiter missions or sample return missions where the total propulsion time could greatly exceed the expected lifetime of an individual thruster. This methodology has been applied to the investigation of NEP missions to the outer planets where examples are presented of both constrained and optimized trajectories.

  14. Breakthrough Propulsion Physics Project: Project Management Methods

    Science.gov (United States)

    Millis, Marc G.

    2004-01-01

    To leap past the limitations of existing propulsion, the NASA Breakthrough Propulsion Physics (BPP) Project seeks further advancements in physics from which new propulsion methods can eventually be derived. Three visionary breakthroughs are sought: (1) propulsion that requires no propellant, (2) propulsion that circumvents existing speed limits, and (3) breakthrough methods of energy production to power such devices. Because these propulsion goals are presumably far from fruition, a special emphasis is to identify credible research that will make measurable progress toward these goals in the near-term. The management techniques to address this challenge are presented, with a special emphasis on the process used to review, prioritize, and select research tasks. This selection process includes these key features: (a) research tasks are constrained to only address the immediate unknowns, curious effects or critical issues, (b) reliability of assertions is more important than the implications of the assertions, which includes the practice where the reviewers judge credibility rather than feasibility, and (c) total scores are obtained by multiplying the criteria scores rather than by adding. Lessons learned and revisions planned are discussed.

  15. An Overview of Cube-Satellite Propulsion Technologies and Trends

    Directory of Open Access Journals (Sweden)

    Akshay Reddy Tummala

    2017-12-01

    Full Text Available CubeSats provide a cost effective means to perform scientific and technological studies in space. Due to their affordability, CubeSat technologies have been diversely studied and developed by educational institutions, companies and space organizations all over the world. The CubeSat technology that is surveyed in this paper is the propulsion system. A propulsion system is the primary mobility device of a spacecraft and helps with orbit modifications and attitude control. This paper provides an overview of micro-propulsion technologies that have been developed or are currently being developed for CubeSats. Some of the micro-propulsion technologies listed have also flown as secondary propulsion systems on larger spacecraft. Operating principles and key design considerations for each class of propulsion system are outlined. Finally, the performance factors of micro-propulsion systems have been summarized in terms of: first, a comparison of thrust and specific impulse for all propulsion systems; second, a comparison of power and specific impulse, as also thrust-to-power ratio and specific impulse for electric propulsion systems.

  16. Characteristics of the Papua New Guinean dentition. I Shovel-shaped incisors and canines associated with lingual tubercles.

    Science.gov (United States)

    Doran, G A

    1977-10-01

    The prevalence of shovel-shaped and lingual tubercles in maxillary incisors and canines in four groups of people in Papua New Guinea is reported. The shovel shape was not common among the people of Highland New Guinea but its presence in Papuans was comparable with that in Mongoloid races.

  17. Colgajo lingual para cierre de fístula oronasal: aportación a la técnica Lingual Flap for Closure of Oronasal Fistula: Contribution to the technique

    Directory of Open Access Journals (Sweden)

    Carlos Licéaga-Escalera

    2012-03-01

    Full Text Available La fístula oronasal es la complicación más común posterior a una palatoplastía y frecuentemente requiere de una reparación secundaria. Se ha desarrollado una gran cantidad de técnicas quirúrgicas para su manejo, siendo una de las más populares el colgajo lingual. A pesar de la excelente vascularidad de la lengua, para asegurar la viabilidad del colgajo, éste debe ser manejado con extremo cuidado durante el procedimiento. Con este propósito sugerimos el uso de una platina acrílica en forma de herradura que aporta estabilidad e inmoviliza la lengua durante la cirugía, lo que facilita el procedimiento y ayuda a evitar errores durante el diseño y el levantamiento del colgajo.The oronasal fistula is the most common complication after a palatoplasty and it frequently needs a secondary repair. A great number of surgical techniques have been developed for the management of this condition. The lingual flap is one of the most popular treatments. In spite of the excellent vascularity of the tongue, it must be handled carefully during the procedure to assure the viability of the flap. For this reason we suggest the use of an acrylic slide in the shape of horse-shoe that improves the stability and immobilises the tongue during the surgery. This makes the procedure easier and helps to avoid mistakes during the design and the raising of the flap.

  18. Padronização de um método para mensuração das tábuas ósseas vestibular e lingual dos maxilares na Tomografia Computadorizada de Feixe Cônico (Cone Beam Methodology standardization for measuring buccal and lingual alveolar bone plates using Cone Beam Computed Tomography

    Directory of Open Access Journals (Sweden)

    Marcos Cezar Ferreira

    2010-02-01

    Full Text Available INTRODUÇÃO: a espessura das tábuas ósseas que recobrem os dentes por vestibular e lingual constitui um dos fatores limitantes da movimentação dentária. O avanço tecnológico em Imaginologia permitiu avaliar detalhadamente essas regiões anatômicas por meio da utilização da tomografia computadorizada de feixe cônico (TCFC. OBJETIVO: descrever e padronizar, pormenorizadamente, um método para mensuração das tábuas ósseas vestibular e lingual dos maxilares nas imagens de tomografia computadorizada de feixe cônico. METODOLOGIA: a padronização digital da posição da imagem da face deve constituir o primeiro passo antes da seleção dos cortes de TCFC. Dois cortes axiais de cada maxilar foram empregados para a mensuração da espessura do osso alveolar vestibular e lingual. Utilizou-se como referência a junção cemento-esmalte dos primeiros molares permanentes, tanto na arcada superior quanto na inferior. RESULTADOS: cortes axiais paralelos ao plano palatino foram indicados para avaliação quantitativa do osso alveolar na maxila. Na arcada inferior, os cortes axiais devem ser paralelos ao plano oclusal funcional. CONCLUSÃO: o método descrito apresenta reprodutibilidade para utilização em pesquisas, assim como para a avaliação clínica das repercussões periodontais da movimentação dentária, ao permitir a comparação de imagens pré e pós-tratamento.INTRODUCTION: The thickness of the buccal and lingual bone plates constitutes one of the limiting factors of the orthodontic movement. The imaging technology has permitted the evaluation of this anatomical region, by means of cone beam computed tomography. PURPOSE: To describe and standardize, in details, a method for measuring the buccal and lingual bone plate thickness in CBCT images. METHODOLOGY: Digital standardization of face image should constitute the first step before the selection of CBCT slices. Two axial sections of each jaw were used for measuring the thickness

  19. Propulsion of liposomes using bacterial motors

    International Nuclear Information System (INIS)

    Zhang Zhenhai; Li Kejie; Li Zhifei; Yu Wei; Xie Zhihong; Shi Zhiguo

    2013-01-01

    Here we describe the utilization of flagellated bacteria as actuators to propel spherical liposomes by attaching bacteria to the liposome surface. Bacteria were stably attached to liposomes using a cross-linking antibody. The effect of the number of attached bacteria on propulsion speed was experimentally determined. The effects of bacterial propulsion on the bacteria–antibody–liposome complex were stochastic. We demonstrated that liposomal mobility increased when bacteria were attached, and the propulsion speed correlated with the number of bacteria. (paper)

  20. Exotic power and propulsion concepts

    International Nuclear Information System (INIS)

    Forward, R.L.

    1990-01-01

    The status of some exotic physical phenomena and unconventional spacecraft concepts that might produce breakthroughs in power and propulsion in the 21st Century are reviewed. The subjects covered include: electric, nuclear fission, nuclear fusion, antimatter, high energy density materials, metallic hydrogen, laser thermal, solar thermal, solar sail, magnetic sail, and tether propulsion

  1. The effect of food bolus location on jaw movement smoothness and masticatory efficiency.

    Science.gov (United States)

    Molenaar, W N B; Gezelle Meerburg, P J; Luraschi, J; Whittle, T; Schimmel, M; Lobbezoo, F; Peck, C C; Murray, G M; Minami, I

    2012-09-01

    Masticatory efficiency in individuals with extensive tooth loss has been widely discussed. However, little is known about jaw movement smoothness during chewing and the effect of differences in food bolus location on movement smoothness and masticatory efficiency. The aim of this study was to determine whether experimental differences in food bolus location (anterior versus posterior) had an effect on masticatory efficiency and jaw movement smoothness. Jaw movement smoothness was evaluated by measuring jerk-cost (calculated from acceleration) with an accelerometer that was attached to the skin of the mentum of 10 asymptomatic subjects, and acceleration was recorded during chewing on two-colour chewing gum, which was used to assessed masticatory efficiency. Chewing was performed under two conditions: posterior chewing (chewing on molars and premolars only) and anterior chewing (chewing on canine and first premolar teeth only). Jerk-cost and masticatory efficiency (calculated as the ratio of unmixed azure colour to the total area of gum, the unmixed fraction) were compared between anterior and posterior chewing with the Wilcoxon signed rank test (two-tailed). Subjects chewed significantly less efficiently during anterior chewing than during posterior chewing (P = 0·0051). There was no significant difference in jerk-cost between anterior and posterior conditions in the opening phase (P = 0·25), or closing phase (P = 0·42). This is the first characterisation of the effect of food bolus location on jaw movement smoothness at the same time as recording masticatory efficiency. The data suggest that anterior chewing decreases masticatory efficiency, but does not influence jerk-cost. © 2012 Blackwell Publishing Ltd.

  2. Operationally efficient propulsion system study (OEPSS) data book. Volume 6; Space Transfer Propulsion Operational Efficiency Study Task of OEPSS

    Science.gov (United States)

    Harmon, Timothy J.

    1992-01-01

    This document is the final report for the Space Transfer Propulsion Operational Efficiency Study Task of the Operationally Efficient Propulsion System Study (OEPSS) conducted by the Rocketdyne Division of Rockwell International. This Study task studied, evaluated and identified design concepts and technologies which minimized launch and in-space operations and optimized in-space vehicle propulsion system operability.

  3. The effect of food bolus location on jaw movement smoothness and masticatory efficiency

    NARCIS (Netherlands)

    Molenaar, W.N.B.; Gezelle Meerburg, P.J.; Luraschi, J.; Whittle, T.; Schimmel, M.; Lobbezoo, F.; Peck, C.C.; Murray, G.M.; Minami, I.

    2012-01-01

    Masticatory efficiency in individuals with extensive tooth loss has been widely discussed. However, little is known about jaw movement smoothness during chewing and the effect of differences in food bolus location on movement smoothness and masticatory efficiency. The aim of this study was to

  4. Main Propulsion Test Article (MPTA)

    Science.gov (United States)

    Snoddy, Cynthia

    2010-01-01

    Scope: The Main Propulsion Test Article integrated the main propulsion subsystem with the clustered Space Shuttle Main Engines, the External Tank and associated GSE. The test program consisted of cryogenic tanking tests and short- and long duration static firings including gimbaling and throttling. The test program was conducted on the S1-C test stand (Position B-2) at the National Space Technology Laboratories (NSTL)/Stennis Space Center. 3 tanking tests and 20 hot fire tests conducted between December 21 1 1977 and December 17, 1980 Configuration: The main propulsion test article consisted of the three space shuttle main engines, flightweight external tank, flightweight aft fuselage, interface section and a boilerplate mid/fwd fuselage truss structure.

  5. NASA's Nuclear Thermal Propulsion Project

    Science.gov (United States)

    Houts, Michael G.; Mitchell, Doyce P.; Kim, Tony; Emrich, William J.; Hickman, Robert R.; Gerrish, Harold P.; Doughty, Glen; Belvin, Anthony; Clement, Steven; Borowski, Stanley K.; hide

    2015-01-01

    The fundamental capability of Nuclear Thermal Propulsion (NTP) is game changing for space exploration. A first generation NTP system could provide high thrust at a specific impulse above 900 s, roughly double that of state of the art chemical engines. Characteristics of fission and NTP indicate that useful first generation systems will provide a foundation for future systems with extremely high performance. The role of a first generation NTP in the development of advanced nuclear propulsion systems could be analogous to the role of the DC- 3 in the development of advanced aviation. Progress made under the NTP project could also help enable high performance fission power systems and Nuclear Electric Propulsion (NEP).

  6. Nuclear merchant ship propulsion

    International Nuclear Information System (INIS)

    Schroeder, E.; Jager, W.; Schafstall, H.G.

    1977-01-01

    The operation of about 300 nuclear naval vessels has proven the feasibility of nuclear ship propulsion. Until now six non military ships have been built or are under construction. In the Soviet Union two nuclear icebreakers are in operation, and a third one is under construction. In the western world three prototype merchant ships have been built. Of these ships only the NS OTTO HAHN is in operation and provides valuable experience for future large scale use of nuclear merchant ship propulsion. In many countries studies and plans are made for future nuclear merchant ships. Types of vessels investigated are large containerships, tankers and specialized ships like icebreakers or ice-breaking ships. The future of nuclear merchant ship propulsion depends on three interrelated items: (1) nuclear ship technology; (2) economy of nuclear ship propulsion; (3) legal questions. Nuclear merchant ship technology is based until now on standard ship technology and light water reactor technology. Except for special questions due to the non-stationary type of the plant entirely new problems do not arise. This has been proven by the recent conceptual licensing procedure for a large nuclear containership in Germany. The economics of nuclear propulsion will be under discussion until they are proven by the operation of privately owned lead ships. Unsolved legal questions e.g. in connection with port entry permissions are at present another problem for nuclear shipping. Efforts are made to solve these questions on an international basis. The future development of nuclear energy electricity production in large land based plants will stimulate the employment of smaller units. Any future development of long distance sea transport will have to take this opportunity of a reliable and economic energy supply into account

  7. Amniotic fluid index predicts the relief of variable decelerations after amnioinfusion bolus.

    Science.gov (United States)

    Spong, C Y; McKindsey, F; Ross, M G

    1996-10-01

    Our purpose was to determine whether intrapartum amniotic fluid index before amnioinfusion can be used to predict response to therapeutic amnioinfusion. Intrapartum patients (n = 85) with repetitive variable decelerations in fetal heart rate that necessitated amnioinfusion (10 ml/min for 60 minutes) underwent determination of amniotic fluid index before and after bolus amnioinfusion. The fetal heart tracing was scored (scorer blinded to amniotic fluid index values) for number and characteristics of variable decelerations before and 1 hour after initiation of amnioinfusion. The amnioinfusion was considered successful if it resulted in a decrease of > or = 50% in total number of variable decelerations or a decrease of > or = 50% in the rate of atypical or severe variable decelerations after administration of the bolus. Spontaneous vaginal births before completion of administration of the bolus (n = 18) were excluded from analysis. The probability of success of amnioinfusion in relation to amniotic fluid index was analyzed with the chi(2) test for progressive sequence. The mean amniotic fluid index before amnioinfusion was 6.2 +/- 3.3 cm. An amniotic fluid index of amnioinfusion decreased with increasing amniotic fluid index before amnioinfusion (76% [16/21] when initial amniotic fluid index was 0 to 4 cm, 63% [17/27] when initial amniotic fluid index was 4 to 8 cm, 44% [7/16] when initial amniotic fluid index was 8 to 12 cm, and 33% [1/3] when initial amniotic fluid index was > 12 cm, p = 0.03). The incidence of nuchal cords or true umbilical cord knots increased in relation to amniotic fluid index before amnioinfusion. Amniotic fluid index before amnioinfusion can be used to predict the success of amnioinfusion for relief of variable decelerations in fetal heart rate. Failure of amnioinfusion at a high amniotic fluid index before amnioinfusion may be explained by the increased prevalence of nuchal cords or true knots in the umbilical cord.

  8. An Airbreathing Launch Vehicle Design with Turbine-Based Low-Speed Propulsion and Dual Mode Scramjet High-Speed Propulsion

    Science.gov (United States)

    Moses, P. L.; Bouchard, K. A.; Vause, R. F.; Pinckney, S. Z.; Ferlemann, S. M.; Leonard, C. P.; Taylor, L. W., III; Robinson, J. S.; Martin, J. G.; Petley, D. H.

    1999-01-01

    Airbreathing launch vehicles continue to be a subject of great interest in the space access community. In particular, horizontal takeoff and horizontal landing vehicles are attractive with their airplane-like benefits and flexibility for future space launch requirements. The most promising of these concepts involve airframe integrated propulsion systems, in which the external undersurface of the vehicle forms part of the propulsion flowpath. Combining of airframe and engine functions in this manner involves all of the design disciplines interacting at once. Design and optimization of these configurations is a most difficult activity, requiring a multi-discipline process to analytically resolve the numerous interactions among the design variables. This paper describes the design and optimization of one configuration in this vehicle class, a lifting body with turbine-based low-speed propulsion. The integration of propulsion and airframe, both from an aero-propulsive and mechanical perspective are addressed. This paper primarily focuses on the design details of the preferred configuration and the analyses performed to assess its performance. The integration of both low-speed and high-speed propulsion is covered. Structural and mechanical designs are described along with materials and technologies used. Propellant and systems packaging are shown and the mission-sized vehicle weights are disclosed.

  9. Propulsive options for a manned Mars transportation system

    International Nuclear Information System (INIS)

    Braun, R.D.; Blersch, D.J.

    1989-01-01

    In this investigation, five potential manned Mars transportation systems are compared. These options include: (1) a single vehicle, chemically propelled (CHEM) option, (2) a single vehicle, nuclear thermal propulsion (NTP) option, (3) a single vehicle solar electric propulsion (SEP) option, (4) a single vehicle hybrid nuclear electric propulsion (NEP)/CHEM option, and (5) a dual vehicle option (NEP cargo spacecraft and CHEM manned vehicle). In addition to utilizing the initial vehicle weight in low-earth orbit as a measure of mission feasibility, this study addresses the major technological barriers each propulsive scenario must surpass. It is shown that instead of a single clearly superior propulsion system, each means of propulsion may be favored depending upon the specified program policy and the extent of the desired manned flight time. Furthermore, the effect which aerobraking and multiple transfer cycles have upon mission feasibility is considered. 18 refs

  10. Continuous versus bolus intragastric tube feeding for preterm and low birth weight infants with gastro-oesophageal reflux disease.

    Science.gov (United States)

    Richards, Robyn; Foster, Jann P; Psaila, Kim

    2014-07-17

    Gastro-oesophageal reflux disease is a particularly common condition in preterm and low birth weight infants. These infants are also more likely to have excessive regurgitation, as they do not have a fully developed antireflux mechanism. Preterm and low birth weight infants who are unable to suck oral feeds are required to be fed via an intragastric tube for varying lengths of time. Intragastric tube feeding can be delivered by the intermittent bolus or continuous feeding method. Use of continuous or intermittent bolus intragastric feeding may have a positive or negative effect on the incidence or severity of gastro-oesophageal reflux disease. To determine whether continuous or intermittent bolus intragastric tube feeding reduces the number of episodes and the duration of gastro-oesophageal reflux disease (GORD) in preterm and low birth weight infants.We intended to perform subgroup analyses for gestational age; birth weight; age in days from birth at full enteral feeding via intragastric tube (breast vs bottle); frequency of intermittent bolus feed; and type of medication for treatment of GORD (only if medication prescribed and given similarly to both intervention groups). We used the standard search strategy of the Cochrane Neonatal Group as described in The Cochrane Library (www.thecochranelibrary.com) to search for randomised controlled trials (RCTs) in the Cochrane Central Register of Controlled Trials (CENTRAL) (2013, Issue 9), MEDLINE (1966 to September 2013), EMBASE (1980 to September 2013) and the Cumulative Index to Nursing and Allied Health Literature (CINAHL) (1982 to September 2013). We also searched previous reviews, including cross-references, abstracts and conference and symposia proceedings of the Perinatal Society of Australia and New Zealand and the Pediatric Academic Societies (American Pediatric Society/Society for Pediatric Research and European Society for Paediatric Research) from 1990 to 2012. Published and unpublished RCTs and quasi

  11. In vitro assessment of competency for different lingual brackets in sliding mechanics.

    Science.gov (United States)

    Lalithapriya, S; Kumaran, N Kurunji; Rajasigamani, K

    2015-01-01

    To determine the static frictional resistance of different lingual brackets at different second order angulations when coupled with stainless steel (SS) archwire in dry and wet conditions. Using a modified jig, frictional resistance was evaluated under different conditions for a total of 270 upper premolar lingual brackets (0.018″ × 0.025″ - conventional - 7(th) generation and STb, self-ligating - evolution) with no in-built tip or torque together with 0.016″ × 0.022″ straight length SS archwires. For conventional brackets, the archwire was secured with 0.008″ preformed SS short ligature ties. One way analysis of variance with Tukey HSD as post-hoc test was applied for degree wise and bracket wise comparison within dry condition and wet condition. For pair wise comparison Student's t-test was used. Under both conditions the static frictional resistance is significantly higher for self-ligating brackets at 0°, while at 5° and 10° it is higher for 7(th) generation brackets. Statistically, significant difference does not exist at 0° between conventional brackets and the same was found at 5° and 10° between STb and self-ligating brackets. With an increase in second order angulations, all the evaluated samples exhibited an increased frictional value. Wet condition samples obtained a higher value than their corresponding dry condition. The self-ligating bracket evaluated in this in vitro study is not beneficial in reducing friction during en-mass retraction due to its interactive clip type.

  12. The cost-effectiveness and budget impact of stepwise addition of bolus insulin in the treatment of type 2 diabetes: evaluation of the FullSTEP trial.

    Science.gov (United States)

    Saunders, Rhodri; Lian, Jean; Karolicki, Boris; Valentine, William

    2014-12-01

    Abstract Background and aims: Intensification of basal insulin-only therapy in type 2 diabetes is often achieved through addition of bolus insulin 3-times daily. The FullSTEP trial demonstrated that stepwise addition (SWA) of bolus insulin aspart was non-inferior to full basal-bolus (FBB) therapy and reduced the rate of hypoglycemia. Here the cost-effectiveness and budget impact of SWA is evaluated. Cost-effectiveness and budget impact models were developed to assess the cost and quality-of-life (QoL) implications of intensification using SWA compared with FBB in the US setting. At assessment, SWA patients added one bolus dose to their current regimen if the HbA1c target was not met. SWA patients reaching three bolus doses used FBB event rates. Outcomes were evaluated at trial end and projected annually up to 5 years. Models captured hypoglycemic events, the proportion meeting HbA1c target, and self-measured blood glucose. Event rates and QoL utilities were taken from trial data and published literature. Costs were evaluated from a healthcare-payer perspective, reported in 2013 USD, and discounted (like clinical outcomes) at 3.5% annually. This analysis applies to patients with HbA1c 7.0-9.0% and body mass index Budget impact analysis estimated that, by moving from FBB to SWA, a health plan with 77,000 patients with type 2 diabetes, of whom 7.8% annually intensified to basal-bolus therapy, would save USD 1304 per intensifying patient over the trial period. SWA of bolus insulin should be considered a beneficial and cost-saving alternative to FBB therapy for the intensification of treatment in type 2 diabetes.

  13. Distributed propulsion for ships

    OpenAIRE

    Nylund, Vilde

    2017-01-01

    It is anticipated that using distributed electric propulsion (DEP) on conventional ships will increase the total propulsive efficiency. This is mainly due to two reasons; firstly, because the total propeller disk area can be increased. Secondly, because each propeller can be optimised for the local wake where it is operating. In this work, the benefits of using DEP has been investigated for a 14 000 TEU container ship. Based on a literary study of the present state of propeller modelling ...

  14. A novel nuclear-powered propulsion system for ship

    International Nuclear Information System (INIS)

    Liu Tao; Han Weishi

    2003-01-01

    A novel nuclear-powered propulsion system for ship is presented in this paper. In this system, a minitype liquid sodium-cooled reactor is used as power; alkali-metal thermal-to-electric conversion (AMTEC) cells are utilized to transform the heat energy to electric energy and superconducting magneto-hydrodynamic (MHD) work as propulsion. This nuclear-powered propulsion system has great advantages in low noise, high speed, long survivability and simple manipulation. It has great significance for the development of propulsion system. (author)

  15. Center for Advanced Space Propulsion Second Annual Technical Symposium Proceedings

    Science.gov (United States)

    1990-01-01

    The proceedings for the Center for Advanced Space Propulsion Second Annual Technical Symposium are divided as follows: Chemical Propulsion, CFD; Space Propulsion; Electric Propulsion; Artificial Intelligence; Low-G Fluid Management; and Rocket Engine Materials.

  16. Optimized enhancement in helical CT: Experiences with a real-time bolus tracking system in 628 patients

    International Nuclear Information System (INIS)

    Kirchner, J.; Kickuth, R.; Laufer, U.; Noack, M.; Liermann, D.

    2000-01-01

    AIMS: Ultrafast detector technology enables bolus-triggered application of contrast media. In a prospective study we investigated the benefit of this new method with the intention of optimizing enhancement during examination of the chest and abdomen. MATERIALS AND METHODS: In total, we examined 548 patients under standardized conditions. All examinations were performed on a Somatom Plus 4 Power CT system (Siemens Corp., Forchheim, Germany) using the CARE-Bolus software. This produces repetitive low-dose test images (e.g. for the lung: 140 kV, 43 mA, TI 0.5 s) and measures the Hounsfield attenuation in a pre-selected region of interest. After exceeding a defined threshold, a diagnostic spiral CT examination was begun automatically. The data obtained from 321 abdominal CT and 179 lung CT examinations were correlated with different parameters such as age, weight and height of the patients and parameters of vascular access. In a group of 80 patients, the injection of contrast medium was stopped after reaching a pre-defined threshold of an increase of 100 HU over the baseline. Then, we assessed the maximal enhancement of liver, pulmonal artery trunk and aortic arch. RESULTS: There was no correlation between bolus geometry and age, body surface or weight. In helical CT of the abdomen the threshold was reached after a mean trigger time of 27 s (range 13-67 s) and only 65 ml (range 41-105 ml) of contrast medium were administered. In helical CT of the lung the threshold was reached after 21 s (range 12-48 s) and the mean amount of administered contrast medium was 48 ml (range 38-71 ml). CONCLUSION: Bolus triggering allows optimized enhancement of the organs and reduces the dose of contrast material required compared with standard administration. Kirchner, J. (2000). Clinical Radiology 55, 368-373

  17. Optimized enhancement in helical CT: experiences with a real-time bolus tracking system in 628 patients.

    Science.gov (United States)

    Kirchner, J; Kickuth, R; Laufer, U; Noack, M; Liermann, D

    2000-05-01

    Ultrafast detector technology enables bolus-triggered application of contrast media. In a prospective study we investigated the benefit of this new method with the intention of optimizing enhancement during examination of the chest and abdomen. In total, we examined 548 patients under standardized conditions. All examinations were performed on a Somatom Plus 4 Power CT system (Siemens Corp., Forchheim, Germany) using the CARE-Bolus software. This produces repetitive low-dose test images (e.g. for the lung: 140 kV, 43 mA, TI 0.5 s) and measures the Hounsfield attenuation in a pre-selected region of interest. After exceeding a defined threshold, a diagnostic spiral CT examination was begun automatically. The data obtained from 321 abdominal CT and 179 lung CT examinations were correlated with different parameters such as age, weight and height of the patients and parameters of vascular access. In a group of 80 patients, the injection of contrast medium was stopped after reaching a pre-defined threshold of an increase of 100 HU over the baseline. Then, we assessed the maximal enhancement of liver, pulmonal artery trunk and aortic arch. There was no correlation between bolus geometry and age, body surface or weight. In helical CT of the abdomen the threshold was reached after a mean trigger time of 27 s (range 13-67 s) and only 65 ml (range 41-105 ml) of contrast medium were administered. In helical CT of the lung the threshold was reached after 21 s (range 12-48 s) and the mean amount of administered contrast medium was 48 ml (range 38-71 ml). Bolus triggering allows optimized enhancement of the organs and reduces the dose of contrast material required compared with standard administration. Copyright 2000 The Royal College of Radiologists.

  18. The lingual splint: an often forgotten method for fixating pediatric mandibular fractures.

    Science.gov (United States)

    Binahmed, Abdulaziz; Sansalone, Claudio; Garbedian, Justin; Sándor, George K B

    2007-01-01

    Maxillofacial fractures are uncommon in the pediatric population, and their treatment is unique due to the psychological, physiological, developmental and anatomical characteristics of children. We present the case of a boy who was treated in an outpatient dental clinic using a lingual splint for the reduction, stabilization and fixation of a mandibular body fracture. This technique is a reliable, noninvasive procedure that dentists may consider in selected cases by referral to an oral and maxillofacial surgeon. It also limits the discomfort and morbidity that can be associated with maxillomandibular fixation or open reduction and internal fixation in pediatric patients.

  19. Lingual nerve injury II. Observations on sensory recovery after micro-neurosurgical reconstruction

    DEFF Research Database (Denmark)

    Hillerup, S; Stoltze, Kaj

    2007-01-01

    /dull discrimination, warm, cold, location of touch, and brush stroke direction, pain perception and two-point discrimination. The rate of recovery was highest during the first 6 months. Females were more often affected than males, but recovery was not influenced by gender. The distribution of neurogenic discomfort......The aim of this study was to report on neurosensory recovery after micro-surgical lingual nerve repair, and to evaluate the effect on recovery of age, delay in repair and gender of the patient. Seventy-four patients entered the study. The micro-surgical repair performed was direct nerve suture (n...

  20. [The supportive outcome of periodontal non-surgical therapy to severe chronic periodontitis accompanied with malformed lingual groove in lateral incisor for 6 years: a case report].

    Science.gov (United States)

    Li, Zheng; Kang, Jun

    2011-06-01

    To track the initiating and developing process of one case diagnosed as chronic periodontitis accompanied with malformed lingual groove in maxillary lateral incisor and report the long-term prognosis to the periodontal conservative and supportive therapy. The patient was diagnosed with mild chronic periodontitis 6 years ago and accepted routine periodontal scaling and root planning (SRP) plus supportive periodontal therapy (SPT) one time. Two years later the periodontal condition deteriorated by deep pockets in molars and severe bone destruction around the maxillary lateral incisor with malformed lingual groove. After SRP in sites which pocket depth more than 4mm plus root canal therapy and lingual groove plasty of maxillary right lateral incisor, the SPT regularly proceeded at 3rd, 6th and 12th month. At present the whole periodontal tissue was healthy, the bone lesion around maxillary lateral incisor recovered well, the tooth had no mobile, the cosmetic effect andtooth function was in good state, and the patient was very satisfied.

  1. An Investigation of Bilateral Symmetry During Manual Wheelchair Propulsion.

    Science.gov (United States)

    Soltau, Shelby L; Slowik, Jonathan S; Requejo, Philip S; Mulroy, Sara J; Neptune, Richard R

    2015-01-01

    Studies of manual wheelchair propulsion often assume bilateral symmetry to simplify data collection, processing, and analysis. However, the validity of this assumption is unclear. Most investigations of wheelchair propulsion symmetry have been limited by a relatively small sample size and a focus on a single propulsion condition (e.g., level propulsion at self-selected speed). The purpose of this study was to evaluate bilateral symmetry during manual wheelchair propulsion in a large group of subjects across different propulsion conditions. Three-dimensional kinematics and handrim kinetics along with spatiotemporal variables were collected and processed from 80 subjects with paraplegia while propelling their wheelchairs on a stationary ergometer during three different conditions: level propulsion at their self-selected speed (free), level propulsion at their fastest comfortable speed (fast), and propulsion on an 8% grade at their level, self-selected speed (graded). All kinematic variables had significant side-to-side differences, primarily in the graded condition. Push angle was the only spatiotemporal variable with a significant side-to-side difference, and only during the graded condition. No kinetic variables had significant side-to-side differences. The magnitudes of the kinematic differences were low, with only one difference exceeding 5°. With differences of such small magnitude, the bilateral symmetry assumption appears to be reasonable during manual wheelchair propulsion in subjects without significant upper-extremity pain or impairment. However, larger asymmetries may exist in individuals with secondary injuries and pain in their upper extremity and different etiologies of their neurological impairment.

  2. Bolus timing in high-pitch CT angiography of the aorta

    International Nuclear Information System (INIS)

    Beeres, Martin; Loch, Matthias; Schulz, Boris; Kerl, Matthias; Al-Butmeh, Firas; Bodelle, Boris; Herrmann, Eva; Gruber-Rouh, Tatjana; Lee, Clara; Jacobi, Volkmar; Vogl, Thomas J.

    2013-01-01

    Objective: To investigate the bolus geometry in high-pitch CT angiography (CTA) of the aorta without ECG synchronisation in comparison to single-source CT. Methods: Overall 160 consecutive patients underwent CTA either in conventional single-source mode with a pitch of 1.2 (group 1), or in dual-source mode with a pitch of 3.0 (groups 2, 3 and 4) using different contrast media timings with bolus triggering at 140 HU (5 s, group 1; 10 s, group 2; 12 s, group 3; 14 s, group 4). Contrast material, saline flush, flow rate and kV/mAs settings were kept equal for optimum comparability. Aortic attenuation was measured along the z-axis of the patient at different anatomic landmarks and subjective image quality was compared. Results: The most homogeneous enhancement of the aorta was reached with a delay of 10 s after reaching the trigger threshold. The imaging length was not significantly different, but the examination time was significantly (p < 0.001) shorter in the high-pitch group (7.7 s vs. 1.7 s for group 1 vs. 2, 3 and 4). Conclusion: In high-pitch CT angiography using a start delay of 10 s after a trigger threshold of 140 HU in the descending aorta is reached, a homogenous contrast along the z-axis is accomplished

  3. Bolus electron conformal therapy for the treatment of recurrent inflammatory breast cancer: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Michelle M., E-mail: mmkim@mdanderson.org [Department of Radiation Oncology, University of Texas M.D. Anderson Cancer Center, Houston, TX (United States); Kudchadker, Rajat J.; Kanke, James E.; Zhang, Sean; Perkins, George H. [Department of Radiation Oncology, University of Texas M.D. Anderson Cancer Center, Houston, TX (United States)

    2012-07-01

    The treatment of locoregionally recurrent breast cancer in patients who have previously undergone radiation therapy is challenging. Special techniques are often required that both eradicate the disease and minimize the risks of retreatment. We report the case of a patient with an early-stage left breast cancer who developed inflammatory-type recurrence requiring re-irradiation of the chest wall using bolus electron conformal therapy with image-guided treatment delivery. The patient was a 51-year-old woman who had undergone lumpectomy, axillary lymph node dissection, and adjuvant whole-breast radiation therapy for a stage I left breast cancer in June 1998. In March 2009, she presented at our institution with biopsy-proven recurrent inflammatory carcinoma and was aggressively treated with multi-agent chemotherapy followed by mastectomy that left a positive surgical margin. Given the patient's prior irradiation and irregular chest wall anatomy, bolus electron conformal therapy was used to treat her chest wall and draining lymphatics while sparing the underlying soft tissue. The patient still had no evidence of disease 21 months after treatment. Our results indicate that bolus electron conformal therapy is an accessible, effective radiation treatment approach for recurrent breast cancer in patients with irregular chest wall anatomy as a result of surgery. This approach may complement standard techniques used to reduce locoregional recurrence in the postmastectomy setting.

  4. Intravenous Bolus versus Continuous Infusion of Famotidine or Ranitidine on 24 H Intragastric Acidity in Fasting Healthy Volunteers

    Directory of Open Access Journals (Sweden)

    ABR Thomson

    1995-01-01

    Full Text Available Infusions of H2-receptor antagonists may be clinically indicated to maintain intragastric pH above 4 to reduce acute gastric mucosal lesions or to treat patients with bleeding peptic ulcers. Eight fasting healthy volunteers were randomly assigned to receive ranitidine infusion alone (150 mg/day, ranitidine infusion plus 50 mg bolus injection of ranitidine (total of 200 mg/day, famotidine infusion alone (40 mg/day or famotidine infusion plus 40 mg bolus injection of famotidine (total of 80 mg/day. Gastric fluid contents were aspirated for 24 h and collected as half-hourly samples in which pH measurements were made. Measures analyzed were mean and median pH, percentage pH at or below 3, 4 or 5 for the 24 h period, daytime, evening and nighttime. The data for each of the variables were analyzed as a Latin square crossover design of variance therapy; base pH before treatment administration in each crossover phase was employed as the covariant. Significant differential treatment means were tested by Newman-Keul’s multiple range test at the 5% level of significance. The mean and median evening pH were higher after famotidine than after ranitidine infusion, but all other pH readings were similar when using these doses. The addition of an initial loading bolus of 50 mg ranitidine to the ranitidine infusion did not result in any added differences in pH, whereas the addition of an initial loading bolus of 40 mg famotidine to the famotidine infusion resulted in a higher 24 h median pH, as well as a lower percentage of pH values of 4 or below, 16.6% versus 28.5%, P<0.05. However, the loading doses of ranitidine and famotidine were not equivalent in potency, and studies are needed to compare the potency of equivalent doses of ranitidine and famotidine when given by bolus plus infusion. Also the clinical relevance of these findings needs to be explored further in the type of individuals potentially requiring intravenous H2-receptor antagonists.

  5. An overview of the NASA Advanced Propulsion Concepts program

    International Nuclear Information System (INIS)

    Curran, F.M.; Bennett, G.L.; Frisbee, R.H.; Sercel, J.C.; Lapointe, M.R.

    1992-07-01

    NASA Advanced Propulsion Concepts (APC) program for the development of long-term space propulsion system schemes is managed by both NASA-Lewis and the JPL and is tasked with the identification and conceptual development of high-risk/high-payoff configurations. Both theoretical and experimental investigations have been undertaken in technology areas deemed essential to the implementation of candidate concepts. These APC candidates encompass very high energy density chemical propulsion systems, advanced electric propulsion systems, and an antiproton-catalyzed nuclear propulsion concept. A development status evaluation is presented for these systems. 45 refs

  6. 46 CFR 121.620 - Propulsion engine control systems.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Propulsion engine control systems. 121.620 Section 121... Propulsion engine control systems. (a) A vessel must have two independent means of controlling each propulsion engine. Control must be provided for the engine speed, direction of shaft rotation, and engine...

  7. Wisdom tooth extraction causing lingual nerve and styloglossus muscle damage: a mimic of multiple cranial nerve palsies

    OpenAIRE

    Carr, A. S.; Evans, M.; Shah, S.; Catania, S.; Warren, J. D.; Gleeson, M. J.; Reilly, M. M.

    2017-01-01

    The combination of tongue hemianaesthesia, dysgeusia, dysarthria and dysphagia suggests the involvement of multiple cranial nerves. We present a case with sudden onset of these symptoms immediately following wisdom tooth extraction and highlight the clinical features that allowed localisation of the lesion to a focal, iatrogenic injury of the lingual nerve and adjacent styloglossus muscle.

  8. Monofilament Vaporization Propulsion (MVP) System, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Monofilament Vaporization Propulsion (MVP) is a new propulsion technology targeted at secondary payload applications. It does not compromise on performance while...

  9. 46 CFR 184.620 - Propulsion engine control systems.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Propulsion engine control systems. 184.620 Section 184... Communications Systems § 184.620 Propulsion engine control systems. (a) A vessel must have two independent means of controlling each propulsion engine. Control must be provided for the engine speed, direction of...

  10. In-Space Propulsion Technologies for Robotic Exploration of the Solar System

    Science.gov (United States)

    Johnson, Les; Meyer, Rae Ann; Frame, Kyle

    2006-01-01

    Supporting NASA's Science Mission Directorate, the In-Space Propulsion Technology Program is developing the next generation of space propulsion technologies for robotic, deep-space exploration. Recent technological advancements and demonstrations of key, high-payoff propulsion technologies have been achieved and will be described. Technologies under development and test include aerocapture, solar electric propulsion, solar sail propulsion, and advanced chemical propulsion.

  11. SU-E-T-71: A Radiochromic Film Based Quantitative Assessment of Thermoplastic Mask Bolus Effect in Head and Neck IMRT/VMAT

    Energy Technology Data Exchange (ETDEWEB)

    Kalavagunta, C; Lin, M; Snider, J; Xu, H; Schrum, A; Vadnais, P; Marter, K; Suntharalingam, M; Prado, K [University of Maryland School of Medicine, Baltimore, MD (United States)

    2015-06-15

    Purpose: To quantify the factors leading to thermoplastic mask bolus-associated-increased skin dose in head and neck IMRT/VMAT using EBT2 film. Methods: EBT2 film placed beneath a dual layer 3-point ORFIT head, neck and shoulder mask was used to test the effect of mask thickness, beam modulation, air gap, and beam obliquity on bolus effect. Mask thickness was varied based on the distribution of 1.6mm Orfilight layer on top of 2 mm Efficast layer. Beam modulation was varied by irradiating the film with an open field (no beam modulation) and a step and shoot field (beam modulation). Air gap between mask and film was varied from 0 to 5mm. Beam obliquity was varied by irradiating the film at gantry angles of 0°, 35°, and 70°.Finally, film strips placed on a Rando phantom under an Orfit mask, in regions of expected high dose, were irradiated using 5 IMRT and 5 VMAT plans with various modulation levels (modulation factor 2 to 5) and the results were compared with those obtained placing OSLDs at the same locations. Results: An 18–34% increase in mask bolus effect was observed for three factors where the effect of beam obliquity ≥ beam modulation > mask thickness. No increase in mask bolus effect was observed for change in air gap. A 6–13% increase in dose due to mask bolus effect was observed on film strips. Conclusion: This work underlines the role of beam obliquity and beam modulation combined with thermoplastic mask thickness in increasing mask bolus-associated skin dose in head and neck IMRT/VMAT. One possible method of dose reduction, based on knowledge gained from this work, is inclusion of skin as an avoidance structure in treatment planning. Another approach is to design a mask with the least amount of thermoplastic material necessary for immobilization.

  12. SU-E-T-71: A Radiochromic Film Based Quantitative Assessment of Thermoplastic Mask Bolus Effect in Head and Neck IMRT/VMAT

    International Nuclear Information System (INIS)

    Kalavagunta, C; Lin, M; Snider, J; Xu, H; Schrum, A; Vadnais, P; Marter, K; Suntharalingam, M; Prado, K

    2015-01-01

    Purpose: To quantify the factors leading to thermoplastic mask bolus-associated-increased skin dose in head and neck IMRT/VMAT using EBT2 film. Methods: EBT2 film placed beneath a dual layer 3-point ORFIT head, neck and shoulder mask was used to test the effect of mask thickness, beam modulation, air gap, and beam obliquity on bolus effect. Mask thickness was varied based on the distribution of 1.6mm Orfilight layer on top of 2 mm Efficast layer. Beam modulation was varied by irradiating the film with an open field (no beam modulation) and a step and shoot field (beam modulation). Air gap between mask and film was varied from 0 to 5mm. Beam obliquity was varied by irradiating the film at gantry angles of 0°, 35°, and 70°.Finally, film strips placed on a Rando phantom under an Orfit mask, in regions of expected high dose, were irradiated using 5 IMRT and 5 VMAT plans with various modulation levels (modulation factor 2 to 5) and the results were compared with those obtained placing OSLDs at the same locations. Results: An 18–34% increase in mask bolus effect was observed for three factors where the effect of beam obliquity ≥ beam modulation > mask thickness. No increase in mask bolus effect was observed for change in air gap. A 6–13% increase in dose due to mask bolus effect was observed on film strips. Conclusion: This work underlines the role of beam obliquity and beam modulation combined with thermoplastic mask thickness in increasing mask bolus-associated skin dose in head and neck IMRT/VMAT. One possible method of dose reduction, based on knowledge gained from this work, is inclusion of skin as an avoidance structure in treatment planning. Another approach is to design a mask with the least amount of thermoplastic material necessary for immobilization

  13. New horizons in orthodontics & dentofacial orthopedics: fixed Twin Blocks & TransForce lingual appliances.

    Science.gov (United States)

    Clark, William John

    2011-01-01

    During the 20th century functional appliances evolved from night time wear to more flexible appliances for increased day time wear to full time wear with Twin Block appliances. The current trend is towards fixed functional appliances and this paper introduces the Fixed Twin Block, bonded to the teeth to eliminate problems of compliance in functional therapy. TransForce lingual appliances are pre-activated and may be used in first phase treatment for sagittal and transverse arch development. Alternatively they may be integrated with fixed appliances at any stage of treatment.

  14. Modifications in Wheelchair Propulsion Technique with Speed.

    Science.gov (United States)

    Russell, Ian M; Raina, Shashank; Requejo, Philip S; Wilcox, Rand R; Mulroy, Sara; McNitt-Gray, Jill L

    2015-01-01

    Repetitive loading of the upper limb joints during manual wheelchair (WC) propulsion (WCP) has been identified as a factor that contributes to shoulder pain, leading to loss of independence and decreased quality of life. The purpose of this study was to determine how individual manual WC users with paraplegia modify propulsion mechanics to accommodate expected increases in reaction forces (RFs) generated at the pushrim with self-selected increases in WCP speed. Upper extremity kinematics and pushrim RFs were measured for 40 experienced manual WC users with paraplegia while propelling on a stationary ergometer at self-selected free and fast propulsion speeds. Upper extremity kinematics and kinetics were compared within subject between propulsion speeds. Between group and within-subject differences were determined (α = 0.05). Increased propulsion speed was accompanied by increases in RF magnitude (22 of 40, >10 N) and shoulder net joint moment (NJM, 15 of 40, >10 Nm) and decreases in pushrim contact duration. Within-subject comparison indicated that 27% of participants modified their WCP mechanics with increases in speed by regulating RF orientation relative to the upper extremity segments. Reorientation of the RF relative to the upper extremity segments can be used as an effective strategy for mitigating rotational demands (NJM) imposed on the shoulder at increased propulsion speeds. Identification of propulsion strategies that individuals can use to effectively accommodate for increases in RFs is an important step toward preserving musculoskeletal health of the shoulder and improving health-related quality of life.

  15. Beamed-Energy Propulsion (BEP) Study

    Science.gov (United States)

    George, Patrick; Beach, Raymond

    2012-01-01

    The scope of this study was to (1) review and analyze the state-of-art in beamed-energy propulsion (BEP) by identifying potential game-changing applications, (2) formulate a roadmap of technology development, and (3) identify key near-term technology demonstrations to rapidly advance elements of BEP technology to Technology Readiness Level (TRL) 6. The two major areas of interest were launching payloads and space propulsion. More generally, the study was requested and structured to address basic mission feasibility. The attraction of beamed-energy propulsion (BEP) is the potential for high specific impulse while removing the power-generation mass. The rapid advancements in high-energy beamed-power systems and optics over the past 20 years warranted a fresh look at the technology. For launching payloads, the study concluded that using BEP to propel vehicles into space is technically feasible if a commitment to develop new technologies and large investments can be made over long periods of time. From a commercial competitive standpoint, if an advantage of beamed energy for Earth-to-orbit (ETO) is to be found, it will rest with smaller, frequently launched payloads. For space propulsion, the study concluded that using beamed energy to propel vehicles from low Earth orbit to geosynchronous Earth orbit (LEO-GEO) and into deep space is definitely feasible and showed distinct advantages and greater potential over current propulsion technologies. However, this conclusion also assumes that upfront infrastructure investments and commitments to critical technologies will be made over long periods of time. The chief issue, similar to that for payloads, is high infrastructure costs.

  16. Mapping wordnets from the perspective of inter-lingual equivalence

    Directory of Open Access Journals (Sweden)

    Ewa Katarzyna Rudnicka

    2017-12-01

    Full Text Available Mapping wordnets from the perspective of inter-lingual equivalence This paper explores inter-lingual equivalence from the perspective of linking two large lexico-semantic databases, namely the Princeton WordNet of English and the plWordnet (pl. Słowosieć of Polish. Wordnets are built as networks of lexico-semantic relations between words and their meanings, and constitute a type of monolingual dictionary cum thesaurus. The development of wordnets for different languages has given rise to many wordnet linking projects (e.g. EuroWordNet, Vossen, 2002. Regardless of a linking method used, these projects require defining rules for establishing equivalence links between wordnet building blocks, known as synsets (sets of synonymous lexical units, i.e., lemma-sense pairs. In this paper an analysis is carried out of a set of inter-wordnet relations used in the mapping of the plWordNet onto the Princeton WordNet, and an attempt is made to relate them to equivalence taxonomies described in specialist literature on bilingual lexicography and translation.   Rzutowanie wordnetów w perspektywie ekwiwalencji międzyjęzykowej Artykuł przedstawia analizę zjawiska ekwiwalencji międzyjęzykowej z perspektywy powiązania dwóch wielkich wordnetów: polskiej Słowosieci i angielskiego WordNetu princetońskiego. Wordnety są relacyjnymi bazami danych leksykalno-semantycznych opisującymi sieć relacji leksykalno-semantycznych pomiędzy słowami i ich znaczeniami. Stanowią zatem rodzaj słownika jednojęzycznego połączonego z tezaurusem. Rozwój wordnetów dla wielu języków świata zaowocował następnie ich wzajemnymi powiązaniami. Wymagało to zdefiniowania metodologii dla ustalenia ekwiwalencji pomiędzy ich podstawowymi elementami tzn. synsetami, które są zbiorami synonimicznych jednostek leksykalnych tzn. par lemat numer znaczenia. W artykule analizujemy zbiór relacji międzywordnetowych używanych w rzutowaniu pomiędzy Słowosiecią a Word

  17. Influence of ligation method on friction resistance of lingual brackets with different second-order angulations: an in vitro study.

    Science.gov (United States)

    Pereira, Graziane Olímpio; Gimenez, Carla Maria Melleiro; Prieto, Lucas; Prieto, Marcos Gabriel do Lago; Basting, Roberta Tarkany

    2016-01-01

    To evaluate stainless steel archwire static friction in active and passive self-ligating lingual and conventional brackets with second-order angulations. Two conventional lingual brackets for canines (STb light/Ormco; PSWb/Tecnident), and two self-ligating brackets, one active (In-Ovation L/GAC) and the other passive (3D/ Forestadent), were evaluated. A stainless steel archwire was used at 0°, 3° and 5° angulations. Metal ligatures, conventional elastic ligatures, and low friction elastic ligatures were also tested. A universal testing machine applied friction between brackets and wires, simulating sliding mechanics, to produce 2-mm sliding at 3 mm/minute speed. Two-way analysis of variance demonstrated a significant effect of the interaction between brackets and angulations (p frictional resistance values were observed at 5° angulation for In-Ovation L, PSWb bracket with non conventional ligature, and STb bracket with metal ligature. As for 3D, PSWb with conventional or metal ligatures, and STb brackets with non conventional ligature, showed significantly lower static frictional resistance with 0° angulation. At 0° angulation, STb brackets with metal ties, In-Ovation L brackets and 3D brackets had the lowest frictional resistance. As the angulation increased from 0° to 3°, static friction resistance increased. When angulation increased from 3° to 5°, static friction resistance increased or remained the same. Self-ligating 3D and In-Ovation L brackets, as well as conventional STb brackets, seem to be the best option when sliding mechanics is used to perform lingual orthodontic treatment.

  18. Screening of patients for cochlear implant through a questionnaire online. GroupProfile of patients pre-and peri lingual not summoned

    Directory of Open Access Journals (Sweden)

    Leal, Aquiles Figueiredo

    2010-06-01

    Full Text Available Introduction: Facilitating access to specialized centers and properly screen patients seeking cochlear implants are critical steps for proper rehabilitation. Objective: To describe the group of patients pre-and peri-lingual is not called for in a service evaluation of cochlear implants. Method: A retrospective study analyzed 401 questionnaires of patients pre-and peri-lingual Web site registered in the Central Brazilian cochlear implant. For the failure to call these patients were used as criteria applied some variables: age, use of hearing aids, speech therapy, duration of deafness, type of progression of hearing loss and type of communication used by the patient. Results: The group of patients with pre-and peri-lingual deafness accounted for 34% of total questionnaires completed during the period. The distribution by age found that 54% of patients were over 17 years, 30% between 9 and 17 years, and remaining less than 9 years. The duration of deafness was higher than 20 years in 50% of patients, between 10 and 20 years by 32% between 5 and 10 years in 9% and between 0 and 5 years in 9%. Regarding the performance of voice rehabilitation 58% of patients had performed and 42% did not. Regarding the mode of communication 49% had global communication, 18% LIBRAS, 6% oral communication, 26% no communication. Conclusion: Advanced age, duration of deafness high, so mostly no oral communication and lack of voice rehabilitation were crucial to the failure to call these patients.

  19. Effect of lingual gauze swab placement on pulse oximeter readings in anaesthetised dogs and cats.

    Science.gov (United States)

    Mair, A; Martinez-Taboada, F; Nitzan, M

    2017-01-14

    This study aimed to evaluate the effect of lingual gauze swab placement on pulse oximeter readings in anaesthetised dogs and cats. Following anaesthetic induction, the following pulse oximeter probe configurations were performed: no gauze swab (control), placement of a gauze swab between the tongue and the probe, placement of different thicknesses of gauze swab, placement of red cotton fabric, placement of a sheet of white paper and placement of the probe and gauze swab on different locations on the tongue. Oxygen saturation (SpO 2 ) and peripheral perfusion index (PI) were recorded. Placement of a gauze swab between the pulse oximeter probe and the tongue in anaesthetised dogs and cats resulted in significantly higher SpO 2 values compared with the control group. In dogs, PI values were significantly higher than the control in all groups except the quarter thickness swab group. In cats, PI was significantly higher in the double thickness swab and white paper groups compared with the control. Cats had significantly higher SpO 2 and lower PI values than dogs. The authors propose that increased contact pressure is responsible for significantly higher SpO 2 and PI readings with the use of a lingual gauze swab resulting from changes in transmural pressure and arterial compliance. British Veterinary Association.

  20. Optimization of initial propofol bolus dose for EEG Narcotrend Index-guided transition from sevoflurane induction to intravenous anesthesia in children.

    Science.gov (United States)

    Dennhardt, Nils; Boethig, Dietmar; Beck, Christiane; Heiderich, Sebastian; Boehne, Martin; Leffler, Andreas; Schultz, Barbara; Sümpelmann, Robert

    2017-04-01

    Sevoflurane induction followed by intravenous anesthesia is a widely used technique to combine the benefits of an easier and less traumatic venipuncture after sevoflurane inhalation with a recovery with less agitation, nausea, and vomiting after total intravenous anesthesia (TIVA). Combination of two different anesthetics may lead to unwanted burst suppression in the electroencephalogram (EEG) during the transition phase. The objective of this prospective clinical observational study was to identify the optimal initial propofol bolus dose for a smooth transition from sevoflurane induction to TIVA using the EEG Narcotrend Index (NI). Fifty children aged 1-8 years scheduled for elective pediatric surgery were studied. After sevoflurane induction and establishing of an intravenous access, a propofol bolus dose range 0-5 mg·kg -1 was administered at the attending anesthetist's discretion to maintain a NI between 20 and 64, and sevoflurane was stopped. Anesthesia was continued as TIVA with a propofol infusion dose of 15 mg·kg -1 ·h -1 for the first 15 min, followed by stepwise reduction according to McFarlan's pediatric infusion regime, and remifentanil 0.25 μg·kg -1 ·min -1 . Endtidal concentration of sevoflurane, NI, and hemodynamic data were recorded during the whole study period using a standardized case report form. Propofol plasma concentrations were calculated using the paedfusor dataset and a TIVA simulation program. Median endtidal concentration of sevoflurane at the time of administration of the propofol bolus was 5.1 [IQR 4.7-5.9] Vol%. The median propofol bolus dose was 1.2 [IQR 0.9-2.5] mg·kg -1 and median NI thereafter was 33 [IQR 23-40]. Nine children presented with a NI 13-20 and three children with burst suppression in the EEG (NI 0-12); all of them received an initial propofol bolus dose >2 mg·kg -1 . Regression equation demonstrated that NI 20-64 was achieved with a 95% probability when using a propofol bolus dose of 1 mg·kg -1 after

  1. Advanced Chemical Propulsion for Science Missions

    Science.gov (United States)

    Liou, Larry

    2008-01-01

    The advanced chemical propulsion technology area of NASA's In-Space Technology Project is investing in systems and components for increased performance and reduced cost of chemical propulsion technologies applicable to near-term science missions. Presently the primary investment in the advanced chemical propulsion technology area is in the AMBR high temperature storable bipropellant rocket engine. Scheduled to be available for flight development starting in year 2008, AMBR engine shows a 60 kg payload gain in an analysis for the Titan-Enceladus orbiter mission and a 33 percent manufacturing cost reduction over its baseline, state-of-the-art counterpart. Other technologies invested include the reliable lightweight tanks for propellant and the precision propellant management and mixture ratio control. Both technologies show significant mission benefit, can be applied to any liquid propulsion system, and upon completion of the efforts described in this paper, are at least in parts ready for flight infusion. Details of the technologies are discussed.

  2. Nuclear thermal propulsion workshop overview

    International Nuclear Information System (INIS)

    Clark, J.S.

    1991-01-01

    NASA is planning an Exploration Technology Program as part of the Space Exploration Initiative to return U.S. astronauts to the moon, conduct intensive robotic exploration of the moon and Mars, and to conduct a piloted mission to Mars by 2019. Nuclear Propulsion is one of the key technology thrust for the human mission to Mars. The workshop addresses NTP (Nuclear Thermal Rocket) technologies with purpose to: assess the state-of-the-art of nuclear propulsion concepts; assess the potential benefits of the concepts for the mission to Mars; identify critical, enabling technologies; lay-out (first order) technology development plans including facility requirements; and estimate the cost of developing these technologies to flight-ready status. The output from the workshop will serve as a data base for nuclear propulsion project planning

  3. Enhancing automatic closed-loop glucose control in type 1 diabetes with an adaptive meal bolus calculator - in silico evaluation under intra-day variability.

    Science.gov (United States)

    Herrero, Pau; Bondia, Jorge; Adewuyi, Oloruntoba; Pesl, Peter; El-Sharkawy, Mohamed; Reddy, Monika; Toumazou, Chris; Oliver, Nick; Georgiou, Pantelis

    2017-07-01

    Current prototypes of closed-loop systems for glucose control in type 1 diabetes mellitus, also referred to as artificial pancreas systems, require a pre-meal insulin bolus to compensate for delays in subcutaneous insulin absorption in order to avoid initial post-prandial hyperglycemia. Computing such a meal bolus is a challenging task due to the high intra-subject variability of insulin requirements. Most closed-loop systems compute this pre-meal insulin dose by a standard bolus calculation, as is commonly found in insulin pumps. However, the performance of these calculators is limited due to a lack of adaptiveness in front of dynamic changes in insulin requirements. Despite some initial attempts to include adaptation within these calculators, challenges remain. In this paper we present a new technique to automatically adapt the meal-priming bolus within an artificial pancreas. The technique consists of using a novel adaptive bolus calculator based on Case-Based Reasoning and Run-To-Run control, within a closed-loop controller. Coordination between the adaptive bolus calculator and the controller was required to achieve the desired performance. For testing purposes, the clinically validated Imperial College Artificial Pancreas controller was employed. The proposed system was evaluated against itself but without bolus adaptation. The UVa-Padova T1DM v3.2 system was used to carry out a three-month in silico study on 11 adult and 11 adolescent virtual subjects taking into account inter-and intra-subject variability of insulin requirements and uncertainty on carbohydrate intake. Overall, the closed-loop controller enhanced by an adaptive bolus calculator improves glycemic control when compared to its non-adaptive counterpart. In particular, the following statistically significant improvements were found (non-adaptive vs. adaptive). Adults: mean glucose 142.2 ± 9.4vs. 131.8 ± 4.2mg/dl; percentage time in target [70, 180]mg/dl, 82.0 ± 7.0vs. 89.5 ± 4

  4. Propulsion controlled aircraft computer

    Science.gov (United States)

    Cogan, Bruce R. (Inventor)

    2010-01-01

    A low-cost, easily retrofit Propulsion Controlled Aircraft (PCA) system for use on a wide range of commercial and military aircraft consists of an propulsion controlled aircraft computer that reads in aircraft data including aircraft state, pilot commands and other related data, calculates aircraft throttle position for a given maneuver commanded by the pilot, and then displays both current and calculated throttle position on a cockpit display to show the pilot where to move throttles to achieve the commanded maneuver, or is automatically sent digitally to command the engines directly.

  5. The effect of wheelchair propulsion style on changes in time spent in extreme wrist orientations after a bout of fatiguing propulsion.

    Science.gov (United States)

    Zukowski, Lisa A; Hass, Chris J; Shechtman, Orit; Christou, Evangelos A; Tillman, Mark D

    2017-10-01

    This study compared how wheelchair propulsion styles affect changes in percentage of time spent in extreme wrist orientations, which have been associated with median nerve injury, after a fatiguing bout of propulsion. Twenty novice, non-disabled adult males learned arcing (ARC) and semicircular (SEMI) propulsion styles and utilised each to perform a wheelchair fatigue protocol. ARC and SEMI did not significantly differ in terms of changes after the fatigue protocol in percentage of time spent in extreme flexion/extension or radial/ulnar deviation at the push phase beginning or end. A pattern was observed, although not significant, of greater increases in percentage of time spent in extreme wrist extension and ulnar deviation during the push phase beginning and ulnar deviation during the push phase end while utilising SEMI relative to ARC. This study evinces that individual differences are greater than observed changes in extreme wrist orientations for both propulsion styles. Practitioner Summary: How wheelchair propulsion styles change with fatigue in terms of extreme wrist orientations was examined. This study evinces that individual differences are greater than observed changes in extreme wrist orientations for both propulsion styles and point towards the need for future research on individual differences utilising propulsion styles.

  6. 46 CFR 109.555 - Propulsion boilers.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Propulsion boilers. 109.555 Section 109.555 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS Miscellaneous § 109.555 Propulsion boilers. The master or person in charge and the engineer in charge shall...

  7. 46 CFR 130.120 - Propulsion control.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Propulsion control. 130.120 Section 130.120 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS VESSEL CONTROL, AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Vessel Control § 130.120 Propulsion control. (a) Each vessel must have— (1...

  8. Is effective force application in handrim wheelchair propulsion also efficient?

    NARCIS (Netherlands)

    Bregman, D.J.J.; van Drongelen, S.V.; Veeger, H.E.J.

    2009-01-01

    Background: Efficiency in manual wheelchair propulsion is low, as is the fraction of the propulsion force that is attributed to the moment of propulsion of the wheelchair. In this study we tested the hypothesis that a tangential propulsion force direction leads to an increase in physiological cost,

  9. Split bolus technique in polytrauma: a prospective study on scan protocols for trauma analysis

    NARCIS (Netherlands)

    Beenen, Ludo F. M.; Sierink, Joanne C.; Kolkman, Saskia; Nio, C. Yung; Saltzherr, Teun Peter; Dijkgraaf, Marcel G. W.; Goslings, J. Carel

    2015-01-01

    For the evaluation of severely injured trauma patients a variety of total body computed tomography (CT) scanning protocols exist. Frequently multiple pass protocols are used. A split bolus contrast protocol can reduce the number of passes through the body, and thereby radiation exposure, in this

  10. A cermet fuel reactor for nuclear thermal propulsion

    International Nuclear Information System (INIS)

    Kruger, G.

    1991-01-01

    Work on the cermet fuel reactor done in the 1960's by General Electric (GE) and the Argonne National Laboratory (ANL) that had as its goal the development of systems that could be used for nuclear rocket propulsion as well as closed cycle propulsion system designs for ship propulsion, space nuclear propulsion, and other propulsion systems is reviewed. It is concluded that we can have excellent thermal and mechanical performance with cermet fuel. Thousands of hours of testing were performed on the cermet fuel at both GE and AGL, including very rapid transients and some radiation performance history. We conclude that there are no feasibility issues with cermet fuel. What is needed is reactivation of existing technology and qualification testing of a specific fuel form. We believe this can be done with a minimum development risk

  11. Study of the usefulness on liver CT using intermittent bolus injection method

    International Nuclear Information System (INIS)

    Hayashi, Hideo

    1990-01-01

    Usefulness on the liver CT using intermittent bolus injection method of contrast media (IM-CE) was studied in 108 hepatic space occupying lesions, particularly to analyze hepatocellular carcinoma (HCC). Scans were obtained before, 20∼30 (arterial phase) and 60 seconds (parenchymal phase) after intravenous bolus injection of 65%-diatrizoate (angiografin) or 300 mg I-iopamidol (iopamiron 300), and in case of necessity, added 3∼15 minutes (late phase) after all injections of contrast media. These scans imaging the features of hepatic mass provided us much useful information. Early enhancement of the arterial phase, and early wash out of the parenchymal phase and delayed ring enhancement of the capsule improved the rates of detection to 96%, 60%, and 49% respectively in case of HCC. Especially. at the small HCC (less than 2cm in diameter), these rates were 89%, 50%, and 28% respectively. Combination of these 3 findings suggested the possibility of HCC in comparison with other hepatic mass. The rate of accurate diagnosis of HCC by this IM-CE was 81%. Thus IM-CE CT provides the useful information in diagnosis of hepatic mass and should be considered as the routine examination of hepatic mass. (author)

  12. Overview and future prospects of laser plasma propulsion technology

    International Nuclear Information System (INIS)

    Zheng Zhiyuan; Lu Xin; Zhang Jie

    2003-01-01

    Due to its high cost, low efficiency, complex operation and unsatisfactory recycling, traditional rocket propulsion by chemical fuels has hindered the exploration of outer space to further limits. With the rapid development of laser and space technology, the new technology of laser propulsion exhibits unique advantages and prospects. The mechanism and current development of laser plasma propulsion are reviewed, with mention of the technical problems and focus issues of laser plasma in micro-flight propulsion

  13. Fitting aerodynamics and propulsion into the puzzle

    Science.gov (United States)

    Johnston, Patrick J.; Whitehead, Allen H., Jr.; Chapman, Gary T.

    1987-01-01

    The development of an airbreathing single-stage-to-orbit vehicle, in particular the problems of aerodynamics and propulsion integration, is examined. The boundary layer transition on constant pressure surfaces at hypersonic velocities, and the effects of noise on the transition are investigated. The importance of viscosity, real-gas effects, and drag at hypersonic speeds is discussed. A propulsion system with sufficient propulsive lift to enhance the performance of the vehicle is being developed. The difficulties of engine-airframe integration are analyzed.

  14. NASA's nuclear electric propulsion technology project

    International Nuclear Information System (INIS)

    Stone, J.R.; Sovey, J.S.

    1992-07-01

    The National Aeronautics and Space Administration (NASA) has initiated a program to establish the readiness of nuclear electric propulsion (NEP) technology for relatively near-term applications to outer planet robotic science missions with potential future evolution to system for piloted Mars vehicles. This program was initiated in 1991 with a very modest effort identified with nuclear thermal propulsion (NTP); however, NEP is also an integral part of this program and builds upon NASA's Base Research and Technology Program in power and electric propulsion as well as the SP-100 space nuclear power program. The NEP Program will establish the feasibility and practicality of electric propulsion for robotic and piloted solar system exploration. The performance objectives are high specific impulse (200 greater than I(sub sp) greater than 10000 s), high efficiency (over 0.50), and low specific mass. The planning for this program was initially focussed on piloted Mars missions, but has since been redirected to first focus on 100-kW class systems for relatively near-term robotic missions, with possible future evolution to megawatt-and multi-megawatt-class systems applicable to cargo vehicles supporting human missions as well as to the piloted vehicles. This paper reviews current plans and recent progress for the overall nuclear electric propulsion project and closely related activities. 33 refs

  15. Lower esophageal mucosal ring: correlation of referred symptoms with radiographic findings using a marshmallow bolus.

    Science.gov (United States)

    Smith, D F; Ott, D J; Gelfand, D W; Chen, M Y

    1998-11-01

    The purpose of this investigation was to determine the prevalence of lower esophageal mucosal rings and to correlate the relationship between these mucosal rings and the presence and anatomic level of symptoms evoked using a marshmallow bolus. Our prospective study included 130 patients who underwent barium examination of the esophagus. All patients completed a questionnaire regarding the anatomic location of their symptoms of dysphagia. In addition to a multiphasic examination of the esophagus, all patients also underwent fluoroscopic observation and videotaping while swallowing a marshmallow bolus; any symptoms that were provoked were recorded. Lower esophageal mucosal rings were shown in 26 (20%) of the 130 patients. The diameter of the rings was 9-12 mm in six patients, 13-20 mm in 18 patients, and larger than 20 mm in two patients. In 16 (62%) of the 26 patients, a marshmallow bolus became impacted at the ring; the impaction caused dysphagia in 12 (75%) of the 16 patients. In these 12 patients, dysphagia was referred to the neck in seven, the sternal angle in two, the mid chest in two, and the lower chest in one patient. None of the 12 patients had a pharyngeal or cervical esophageal abnormality that would account for their symptoms. Because proximal referral of symptoms is common in patients with lower esophageal mucosal rings, a thorough radiographic examination of the entire esophagus and esophagogastric region is required regardless of the level of their swallowing complaints.

  16. Multidetector computed tomography with triple-bolus contrast medium administration protocol for preoperative anatomical and functional assessment of potential living renal donors

    International Nuclear Information System (INIS)

    Knox, Matthew K.; Rivers-Bowerman, Michael D.; Bardgett, Harry P.; Cowan, Nigel C.

    2010-01-01

    To evaluate multidetector computed tomography (MDCT) with a triple-bolus contrast administration protocol for preoperative anatomical and functional assessment of living renal donors. Fifty-five potential living renal donors underwent MDCT of which 27 proceeded to donor nephrectomy. A triple-bolus contrast administration protocol was used for simultaneous acquisition of arterial, nephrographic, and excretory phases. MDCT images were independently reviewed in random order by two radiologists blinded to surgical anatomy findings. Diagnostic accuracy for anatomical variants was quantified by sensitivity and specificity. Differential renal function (DRF) was derived from MDCT for 54 patients and compared with technetium-99 m dimercaptosuccinic acid renography (Tc-99 m DMSA). All triple-bolus MDCT examinations were technically adequate. Accessory renal arteries and veins were identified at surgery in 33% (n = 9/27) and 22% (n = 6/27) of donor kidneys. The mean difference between MDCT-derived DRF and DMSA was 0.8% (95% CI 0.1-1.6) with 95% limits of agreement of -4.6% (95% CI -3.3 to -5.9) to 6.3% (95% CI 5.0-7.6). MDCT delivered a mean (SD, range) radiation dose of 9.5 (3.6, 3.6-17.3) mSv. MDCT with a triple-bolus contrast administration provides accurate anatomical and functional evaluation of living renal donors. (orig.)

  17. Multidetector computed tomography with triple-bolus contrast medium administration protocol for preoperative anatomical and functional assessment of potential living renal donors

    Energy Technology Data Exchange (ETDEWEB)

    Knox, Matthew K. [University of Calgary, Faculty of Medicine, UME Office, Health Sciences Centre, Calgary, Alberta (Canada); Rivers-Bowerman, Michael D. [University of British Columbia, Faculty of Medicine, MD Undergraduate Program, Diamond Health Care Centre, Vancouver, British Columbia (Canada); Bardgett, Harry P. [Bradford Teaching Hospitals, Department of Radiology, Bradford (United Kingdom); Cowan, Nigel C. [The Churchill Hospital, Department of Radiology, Oxford (United Kingdom)

    2010-11-15

    To evaluate multidetector computed tomography (MDCT) with a triple-bolus contrast administration protocol for preoperative anatomical and functional assessment of living renal donors. Fifty-five potential living renal donors underwent MDCT of which 27 proceeded to donor nephrectomy. A triple-bolus contrast administration protocol was used for simultaneous acquisition of arterial, nephrographic, and excretory phases. MDCT images were independently reviewed in random order by two radiologists blinded to surgical anatomy findings. Diagnostic accuracy for anatomical variants was quantified by sensitivity and specificity. Differential renal function (DRF) was derived from MDCT for 54 patients and compared with technetium-99 m dimercaptosuccinic acid renography (Tc-99 m DMSA). All triple-bolus MDCT examinations were technically adequate. Accessory renal arteries and veins were identified at surgery in 33% (n = 9/27) and 22% (n = 6/27) of donor kidneys. The mean difference between MDCT-derived DRF and DMSA was 0.8% (95% CI 0.1-1.6) with 95% limits of agreement of -4.6% (95% CI -3.3 to -5.9) to 6.3% (95% CI 5.0-7.6). MDCT delivered a mean (SD, range) radiation dose of 9.5 (3.6, 3.6-17.3) mSv. MDCT with a triple-bolus contrast administration provides accurate anatomical and functional evaluation of living renal donors. (orig.)

  18. Ultrasonic propulsion of kidney stones.

    Science.gov (United States)

    May, Philip C; Bailey, Michael R; Harper, Jonathan D

    2016-05-01

    Ultrasonic propulsion is a novel technique that uses short bursts of focused ultrasonic pulses to reposition stones transcutaneously within the renal collecting system and ureter. The purpose of this review is to discuss the initial testing of effectiveness and safety, directions for refinement of technique and technology, and opinions on clinical application. Preclinical studies with a range of probes, interfaces, and outputs have demonstrated feasibility and consistent safety of ultrasonic propulsion with room for increased outputs and refinement toward specific applications. Ultrasonic propulsion was used painlessly and without adverse events to reposition stones in 14 of 15 human study participants without restrictions on patient size, stone size, or stone location. The initial feasibility study showed applicability in a range of clinically relevant situations, including facilitating passage of residual fragments following ureteroscopy or shock wave lithotripsy, moving a large stone at the ureteropelvic junction with relief of pain, and differentiating large stones from a collection of small fragments. Ultrasonic propulsion shows promise as an office-based system for transcutaneously repositioning kidney stones. Potential applications include facilitating expulsion of residual fragments following ureteroscopy or shock wave lithotripsy, repositioning stones prior to treatment, and repositioning obstructing ureteropelvic junction stones into the kidney to alleviate acute renal colic.

  19. Hybrid-electric propulsion for automotive and aviation applications

    OpenAIRE

    Friedrich, C; Robertson, Paul Andrew

    2014-01-01

    In parallel with the automotive industry, hybrid-electric propulsion is becoming a viable alternative propulsion technology for the aviation sector and reveals potential advantages including fuel savings, lower pollution, and reduced noise emission. Hybrid-electric propulsion systems can take advantage of the synergy between two technologies by utilizing both internal combustion engines and electric motors together, each operating at their respective optimum conditions...

  20. Three-dimensional printer-aided casting of soft, custom silicone boluses (SCSBs) for head and neck radiation therapy.

    Science.gov (United States)

    Chiu, Tsuicheng; Tan, Jun; Brenner, Mathew; Gu, Xuejun; Yang, Ming; Westover, Kenneth; Strom, Tobin; Sher, David; Jiang, Steve; Zhao, Bo

    Custom tissue compensators provide dosimetric advantages for treating superficial or complex anatomy, but currently available fabrication technology is expensive or impractical for most clinical operations and yields compensators that are difficult for patients to tolerate. We aimed to develop an inexpensive, clinically feasible workflow for generating patient-specific, soft, custom silicone boluses (SCSBs) for head-and-neck (HN) radiation therapy. We developed a method using 3-dimensional printed parts for generating SCSBs for the treatment of HN cancers. The clinical workflow for generation of SCSBs was characterized inclusive of patient simulation to treatment in terms of resource time and cost. Dosimetric properties such as percentage depth dose and dose profiles were measured for SCSBs using GaF films. Comprehensive measurements were also conducted on an HN phantom. SCSBs were generated and used for electron or photon based radiation treatments of 7 HN patients with lesions at nose, cheek, eye, or ears. In vivo dose measurements with optically simulated luminescence dosimeters were performed. Total design and fabrication time from patient simulation to radiation treatment start required approximately 1 week, with fabrication constituting 1 to 2 working days depending on bolus surface area, volume, and complexity. Computed tomography and dosimetric properties of the soft bolus were similar to water. In vivo dose measurements on 7 treated patients confirmed that the dose deposition conformed to planned doses. Material costs were lower than currently available hard plastic boluses generated with 3-dimensional printing technology. All treated patients tolerated SCSBs for the duration of therapy. Generation and use of SCSBs for clinical use is feasible and effective for the treatment of HN cancers. Copyright © 2017 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.