  1. Magnetic bead detection using nano-transformers

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyung Kwon; Ahn, Doyeol [Institute of Quantum Information Processing and Systems, University of Seoul, 90 Jeonnong, Dongdaemun, Seoul 130-743 (Korea, Republic of); Hwang, Jong Seung; Hwang, Sung Woo, E-mail: dahn@uos.ac.kr [Research Center for Time-domain Nano-functional Devices and School of Electrical Engineering, Korea University, 5-1 Anam, Sungbuk, Seoul 136-701 (Korea, Republic of)

    2010-11-19

    A novel scheme to detect magnetic beads using a nano-scale transformer with a femtoweber resolution is reported. We have performed a Faraday's induction experiment with the nano-transformer at room temperature. The transformer shows the linear output voltage responses to the sinusoidal input current. When magnetic beads are placed on the transformer, the output responses are increased by an amount corresponding to the added magnetic flux from the beads when compared with the case of no beads on the transformer. In this way, we could determine whether magnetic beads are on top of the transformer in a single particle level.

  2. Magnetic bead detection using nano-transformers.

    Science.gov (United States)

    Kim, Hyung Kwon; Hwang, Jong Seung; Hwang, Sung Woo; Ahn, Doyeol

    2010-11-19

    A novel scheme to detect magnetic beads using a nano-scale transformer with a femtoweber resolution is reported. We have performed a Faraday's induction experiment with the nano-transformer at room temperature. The transformer shows the linear output voltage responses to the sinusoidal input current. When magnetic beads are placed on the transformer, the output responses are increased by an amount corresponding to the added magnetic flux from the beads when compared with the case of no beads on the transformer. In this way, we could determine whether magnetic beads are on top of the transformer in a single particle level.

  3. Magnetic tweezers with high permeability electromagnets for fast actuation of magnetic beads

    Energy Technology Data Exchange (ETDEWEB)

    Chen, La; Offenhäusser, Andreas; Krause, Hans-Joachim [Institute of Bioelectronics (ICS-8/PGI-8), Forschungszentrum Jülich GmbH, 52425 Jülich (Germany)

    2015-04-15

    As a powerful and versatile scientific instrument, magnetic tweezers have been widely used in biophysical research areas, such as mechanical cell properties and single molecule manipulation. If one wants to steer bead position, the nonlinearity of magnetic properties and the strong position dependence of the magnetic field in most magnetic tweezers lead to quite a challenge in their control. In this article, we report multi-pole electromagnetic tweezers with high permeability cores yielding high force output, good maneuverability, and flexible design. For modeling, we adopted a piece-wise linear dependence of magnetization on field to characterize the magnetic beads. We implemented a bi-linear interpolation of magnetic field in the work space, based on a lookup table obtained from finite element simulation. The electronics and software were custom-made to achieve high performance. In addition, the effects of dimension and defect on structure of magnetic tips also were inspected. In a workspace with size of 0.1 × 0.1 mm{sup 2}, a force of up to 400 pN can be applied on a 2.8 μm superparamagnetic bead in any direction within the plane. Because the magnetic particle is always pulled towards a tip, the pulling forces from the pole tips have to be well balanced in order to achieve control of the particle’s position. Active video tracking based feedback control is implemented, which is able to work at a speed of up to 1 kHz, yielding good maneuverability of the magnetic beads.

  4. Simulation of non-linear coaxial line using ferrite beads

    International Nuclear Information System (INIS)

    Furuya, S.; Matsumoto, H.; Tachi, K.; Takano, S.; Irisawa, J.

    2002-01-01

    A ferrite sharpener is a non-linear coaxial line using ferrite beads, which produces high-voltage, high-dV/dt pulses. We have been examining the characteristics of ferrite sharpeners experimentally, varying various parameters. Also we have made the simulation of the ferrite sharpener and compared the predictions with the experimental results in detail to analyze the characteristics of the sharpener. In this report, calculating the magnetization M of the ferrite bead, we divide the bead into n sections radially instead of adopting M at the average radius in the previous report. (author)

  5. Bead Capture and Release on a Magnetic Sensor in a Microfluidic System

    DEFF Research Database (Denmark)

    Dalslet, Bjarke Thomas; Damsgaard, Christian Danvad; Freitas, S.C.

    Planar Hall effect magnetic sensors for detection of biological agents using surface treated magnetic beads are integrated with a fluid injection system. The response of the sensors is used to evaluate bead capture rates for different bead concentrations c and fluid flow rates Q, and to monitor...... subsequent removal of the beads. It is found that the capture rate scales directly with c and that it depends linearly on Q. At low Q the capture rate is only partially due to gravitational sedimentation of beads. At higher Q an additional term proportional to Q becomes important, which is attributed...... to capture of beads by the magnetic fields near the sensor. It is shown that beads can be washed off the sensor surface....

  6. Comparison of non-magnetic and magnetic beads in bead-based assays

    NARCIS (Netherlands)

    Hansenová Maňásková, S.; van Belkum, A.; Endtz, H.P.; Bikker, F.J.; Veerman, E.C.I.; van Wamel, W.J.B.

    2016-01-01

    Multiplex bead-based flow cytometry is an attractive way for simultaneous, rapid and cost-effective analysis of multiple analytes in a single sample. Previously, we developed various bead-based assays using non-magnetic beads coated with Staphylococcus aureus and Streptococcus pneumoniae antigens

  7. Zanamivir immobilized magnetic beads for voltammetric measurement of neuraminidase at gold-modified boron doped diamond electrode

    Energy Technology Data Exchange (ETDEWEB)

    Wahyuni, Wulan Tri, E-mail: wulantriws@gmail.com [Department of Chemistry, Faculty of Mathematics and Natural Sciences, Bogor Agricultural University, Kampus IPB Darmaga, Bogor 16680 (Indonesia); Department of Chemistry, FMIPA, Universitas Indonesia, Kampus UI Depok (Indonesia); Ivandini, Tribidasari A.; Saepudin, Endang [Department of Chemistry, FMIPA, Universitas Indonesia, Kampus UI Depok (Indonesia); Einaga, Yasuaki [Department of Chemistry, Faculty of Science and Technology, Keio University, Hiyoshi 3-14-1, Yokohama 223-8522 (Japan); CREST, JST, 3-14-1 Hiyoshi, Yokohama 223-8522 (Japan)

    2016-04-19

    Biomolecule modified magnetic beads has been widely used in separation and sensing process. This study used streptavidin modified magnetic beads to immobilize biotin modified zanamivir. Biotin-streptavidin affinity facilitates immobilization of zanamivir on magnetic beads. Then interaction of zanamivir and neuraminidase was adopted as basic for enzyme detection. Detection of neuraminidase was performed at gold modified BDD using cyclic voltammetry technique. The measurement was carried out based on alteration of electrochemical signals of working electrode as neuraminidase response. The result showed that zanamivir was successfully immobilized on magnetic beads. The optimum amount of magnetic beads for zanamivir immobilization was 120 ug. Linear responses of neuraminidase were detected in concentration range of 0-15 mU. Detection limit (LOD) of measurement was 2.32 mU (R2 = 0.959) with precision as % RSD of 1.41%. Measurement of neuraminidase on magnetic beads could be also performed in the presence of mucin matrix. The linearity range was 0-8 mU with LOD of 0.64 mU (R2 = 0.950) and % RSD of 7.25%.

  8. Microfluidic magnetic bead conveyor belt.

    Science.gov (United States)

    van Pelt, Stijn; Frijns, Arjan; den Toonder, Jaap

    2017-11-07

    Magnetic beads play an important role in the miniaturization of clinical diagnostics systems. In lab-on-chip platforms, beads can be made to link to a target species and can then be used for the manipulation and detection of this species. Current bead actuation systems utilize complex on-chip coil systems that offer low field strengths and little versatility. We demonstrate a novel system based on an external rotating magnetic field and on-chip soft-magnetic structures to focus the field locally. These structures were designed and optimized using finite element simulations in order to create a number of local flux density maxima. These maxima, to which the magnetic beads are attracted, move over the chip surface in a continuous way together with the rotation of the external field, resulting in a mechanism similar to that of a conveyor belt. A prototype was fabricated using PDMS molding techniques mixed with iron powder for the magnetic structures. In the subsequent experiments, a quadrupole electromagnet was used to create the rotating external field. We observed that beads formed agglomerates that rolled over the chip surface, just above the magnetic structures. Field rotation frequencies between 0.1-50 Hz were tested resulting in magnetic bead speeds of over 1 mm s -1 for the highest frequency. With this, we have shown that our novel concept works, combining a simple design and simple operation with a powerful and versatile method for bead actuation. This makes it a promising method for further research and utilization in lab-on-chip systems.

  9. Microfabricated Passive Magnetic Bead separators

    DEFF Research Database (Denmark)

    Hansen, Mikkel Fougt; Lund-Olesen, Torsten; Smistrup, Kristian

    2006-01-01

    The use and manipulation of functionalized magnetic beads for bioanalysis in lab-on-a-chip systems is receiving growing interest. We have developed microfluidic systems with integrated magnetic structures for the capture and release of magnetic beads. The systems are fabricated in silicon by deep...

  10. Self-organizing magnetic beads for biomedical applications

    International Nuclear Information System (INIS)

    Gusenbauer, Markus; Kovacs, Alexander; Reichel, Franz; Exl, Lukas; Bance, Simon; Özelt, Harald; Schrefl, Thomas

    2012-01-01

    In the field of biomedicine magnetic beads are used for drug delivery and to treat hyperthermia. Here we propose to use self-organized bead structures to isolate circulating tumor cells using lab-on-chip technologies. Typically blood flows past microposts functionalized with antibodies for circulating tumor cells. Creating these microposts with interacting magnetic beads makes it possible to tune the geometry in size, position and shape. We developed a simulation tool that combines micromagnetics and discrete particle dynamics, in order to design micropost arrays made of interacting beads. The simulation takes into account the viscous drag of the blood flow, magnetostatic interactions between the magnetic beads and gradient forces from external aligned magnets. We developed a particle–particle particle–mesh method for effective computation of the magnetic force and torque acting on the particles. - Highlights: ► We propose to use self-organized bead structures to isolate circulating tumor cells. ► Flexible ways are important to get a high probability of catching cancer cells. ► The beads make it possible to tune the geometry in size position and shape.

  11. Microfluidic magnetic bead conveyor belt

    NARCIS (Netherlands)

    van Pelt, S.; Frijns, A.J.H.; den Toonder, J.M.J.

    2017-01-01

    Magnetic beads play an important role in the miniaturization of clinical diagnostics systems. In lab-on-chip platforms, beads can be made to link to a target species and can then be used for the manipulation and detection of this species. Current bead actuation systems utilize complex on-chip coil

  12. Graphene Oxide Conjugated Magnetic Beads for RNA Extraction.

    Science.gov (United States)

    Pham, Xuan-Hung; Baek, Ahruem; Kim, Tae Han; Lee, Sang Hun; Rho, Won-Yeop; Chung, Woo-Jae; Kim, Dong-Eun; Jun, Bong-Hyun

    2017-08-04

    A magnetic material that consists of silica-coated magnetic beads conjugated with graphene oxide (GO) was successfully prepared for facile ribonucleic acid (RNA) extraction. When the GO-modified magnetic beads were applied to separate the RNA from the lysed cell, the cellular RNAs were readily adsorbed to and readily desorbed from the surface of the GO-modified magnetic beads by urea. The amount of RNA extracted by the GO-modified magnetic beads was ≈170 % as much as those of the control extracted by a conventional phenol-based chaotropic solution. These results demonstrate that the facile method of RNA separation by using GO-modified magnetic beads as an adsorbent is an efficient and simple way to purify intact cellular RNAs and/or microRNA from cell lysates. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Magnetic bead micromixer: Influence of magnetic element geometry and field amplitude

    DEFF Research Database (Denmark)

    Lund-Olesen, Torsten; Buus, Bjarke B.; Howalt, Jakob

    2008-01-01

    A scheme for the silicon microfabrication of lab-on-a-chip systems with mixing based on dynamic plugs of magnetic beads is presented. The systems consist of a microfluidic channel integrated with a number of soft magnetic elements by the sides of the channel. The elements are magnetized by a homo......A scheme for the silicon microfabrication of lab-on-a-chip systems with mixing based on dynamic plugs of magnetic beads is presented. The systems consist of a microfluidic channel integrated with a number of soft magnetic elements by the sides of the channel. The elements are magnetized...... by a homogeneous external ac magnetic field. The systems are scalable with respect to the number of magnetic bead plugs and number of parallel channels, and thus they have high potential for use in biological separation using functionalized magnetic beads. The mixing efficiency is characterized for two different...

  14. Asynchronous Magnetic Bead Rotation (AMBR Microviscometer for Label-Free DNA Analysis

    Directory of Open Access Journals (Sweden)

    Yunzi Li

    2014-03-01

    Full Text Available We have developed a label-free viscosity-based DNA detection system, using paramagnetic beads as an asynchronous magnetic bead rotation (AMBR microviscometer. We have demonstrated experimentally that the bead rotation period is linearly proportional to the viscosity of a DNA solution surrounding the paramagnetic bead, as expected theoretically. Simple optical measurement of asynchronous microbead motion determines solution viscosity precisely in microscale volumes, thus allowing an estimate of DNA concentration or average fragment length. The response of the AMBR microviscometer yields reproducible measurement of DNA solutions, enzymatic digestion reactions, and PCR systems at template concentrations across a 5000-fold range. The results demonstrate the feasibility of viscosity-based DNA detection using AMBR in microscale aqueous volumes.

  15. Configurational Statistics of Magnetic Bead Detection with Magnetoresistive Sensors

    DEFF Research Database (Denmark)

    Henriksen, Anders Dahl; Ley, Mikkel Wennemoes Hvitfeld; Flyvbjerg, Henrik

    2015-01-01

    Magnetic biosensors detect magnetic beads that, mediated by a target, have bound to a functionalized area. This area is often larger than the area of the sensor. Both the sign and magnitude of the average magnetic field experienced by the sensor from a magnetic bead depends on the location...... of the bead relative to the sensor. Consequently, the signal from multiple beads also depends on their locations. Thus, a given coverage of the functionalized area with magnetic beads does not result in a given detector response, except on the average, over many realizations of the same coverage. We present...... a systematic theoretical analysis of how this location-dependence affects the sensor response. The analysis is done for beads magnetized by a homogeneous in-plane magnetic field. We determine the expected value and standard deviation of the sensor response for a given coverage, as well as the accuracy...

  16. Theoretical study of in-plane response of magnetic field sensor to magnetic beads magnetized by the sensor self-field

    DEFF Research Database (Denmark)

    Hansen, Troels Borum Grave; Damsgaard, Christian Danvad; Dalslet, Bjarke Thomas

    2010-01-01

    We present a theoretical study of the spatially averaged in-plane magnetic field on square and rectangular magnetic field sensors from a single magnetic bead, a monolayer of magnetic beads, and a half-space filled with magnetic beads being magnetized by the magnetic self-field due to the applied...... bias current through the sensor. The analysis of the single bead response shows that beads always contribute positively to the average magnetic field as opposed to the case for an applied homogeneous magnetic field where the sign of the signal depends on the bead position. General expressions...... and analytical approximations are derived for the sensor response to beads as function of the bead distribution, the bias current, the geometry and size of the sensor, and the bead characteristics. Consequences for the sensor design are exemplified and it is described how the contribution from the self...

  17. On-chip signal amplification of magnetic bead-based immunoassay by aviating magnetic bead chains.

    Science.gov (United States)

    Jalal, Uddin M; Jin, Gyeong Jun; Eom, Kyu Shik; Kim, Min Ho; Shim, Joon S

    2017-11-06

    In this work, a Lab-on-a-Chip (LOC) platform is used to electromagnetically actuate magnetic bead chains for an enhanced immunoassay. Custom-made electromagnets generate a magnetic field to form, rotate, lift and lower the magnetic bead chains (MBCs). The cost-effective, disposable LOC platform was made with a polymer substrate and an on-chip electrochemical sensor patterned via the screen-printing process. The movement of the MBCs is controlled to improve the electrochemical signal up to 230% when detecting beta-type human chorionic gonadotropin (β-hCG). Thus, the proposed on-chip MBC-based immunoassay is applicable for rapid, qualitative electrochemical point-of-care (POC) analysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Plasma membrane isolation using immobilized concanavalin A magnetic beads.

    Science.gov (United States)

    Lee, Yu-Chen; Srajer Gajdosik, Martina; Josic, Djuro; Lin, Sue-Hwa

    2012-01-01

    Isolation of highly purified plasma membranes is the key step in constructing the plasma membrane proteome. Traditional plasma membrane isolation method takes advantage of the differential density of organelles. While differential centrifugation methods are sufficient to enrich for plasma membranes, the procedure is lengthy and results in low recovery of the membrane fraction. Importantly, there is significant contamination of the plasma membranes with other organelles. The traditional agarose affinity matrix is suitable for isolating proteins but has limitation in separating organelles due to the density of agarose. Immobilization of affinity ligands to magnetic beads allows separation of affinity matrix from organelles through magnets and could be developed for the isolation of organelles. We have developed a simple method for isolating plasma membranes using lectin concanavalin A (ConA) magnetic beads. ConA is immobilized onto magnetic beads by binding biotinylated ConA to streptavidin magnetic beads. The ConA magnetic beads are used to bind glycosylated proteins present in the membranes. The bound membranes are solubilized from the magnetic beads with a detergent containing the competing sugar alpha methyl mannoside. In this study, we describe the procedure of isolating rat liver plasma membranes using sucrose density gradient centrifugation as described by Neville. We then further purify the membrane fraction by using ConA magnetic beads. After this purification step, main liver plasma membrane proteins, especially the highly glycosylated ones and proteins containing transmembrane domains could be identified by LC-ESI-MS/MS. While not described here, the magnetic bead method can also be used to isolate plasma membranes from cell lysates. This membrane purification method should expedite the cataloging of plasma membrane proteome.

  19. Bead Capture on Magnetic Sensors in a Microfluidic System

    DEFF Research Database (Denmark)

    Østerberg, Frederik Westergaard; Dalslet, Bjarke Thomas; Damsgaard, Christian Danvad

    2009-01-01

    The accumulation of magnetic beads by gravitational sedimentation and magnetic capture on a planar Hall-effect sensor integrated in a microfluidic channel is studied systematically as a function of the bead concentration, the fluid flow rate, and the sensor bias current. It is demonstrated...... that the sedimentation flux is proportional to the bead concentration and has a power law relation to the fluid flow rate. The mechanisms for the bead accumulation are investigated and it is found that gravitational sedimentation dominates the bead accumulation, whereas the stability of the sedimented beads against...

  20. A novel magnet focusing plate for matrix-assisted laser desorption/ionization analysis of magnetic bead-bound analytes.

    Science.gov (United States)

    Gode, David; Volmer, Dietrich A

    2013-05-15

    Magnetic beads are often used for serum profiling of peptide and protein biomarkers. In these assays, the bead-bound analytes are eluted from the beads prior to mass spectrometric analysis. This study describes a novel matrix-assisted laser desorption/ionization (MALDI) technique for direct application and focusing of magnetic beads to MALDI plates by means of dedicated micro-magnets as sample spots. Custom-made MALDI plates with magnetic focusing spots were made using small nickel-coated neodymium micro-magnets integrated into a stainless steel plate in a 16 × 24 (384) pattern. For demonstrating the proof-of-concept, commercial C-18 magnetic beads were used for the extraction of a test compound (reserpine) from aqueous solution. Experiments were conducted to study focusing abilities, the required laser energies, the influence of a matrix compound, dispensing techniques, solvent choice and the amount of magnetic beads. Dispensing the magnetic beads onto the micro-magnet sample spots resulted in immediate and strong binding to the magnetic surface. Light microscope images illustrated the homogeneous distribution of beads across the surfaces of the magnets, when the entire sample volume containing the beads was pipetted onto the surface. Subsequent MALDI analysis of the bead-bound analyte demonstrated excellent and reproducible ionization yields. The surface-assisted laser desorption/ionization (SALDI) properties of the strongly light-absorbing γ-Fe2O3-based beads resulted in similar ionization efficiencies to those obtained from experiments with an additional MALDI matrix compound. This feasibility study successfully demonstrated the magnetic focusing abilities for magnetic bead-bound analytes on a novel MALDI plate containing small micro-magnets as sample spots. One of the key advantages of this integrated approach is that no elution steps from magnetic beads were required during analyses compared with conventional bead experiments. Copyright © 2013 John Wiley

  1. A High-Throughput SU-8Microfluidic Magnetic Bead Separator

    DEFF Research Database (Denmark)

    Bu, Minqiang; Christensen, T. B.; Smistrup, Kristian

    2007-01-01

    We present a novel microfluidic magnetic bead separator based on SU-8 fabrication technique for high through-put applications. The experimental results show that magnetic beads can be captured at an efficiency of 91 % and 54 % at flow rates of 1 mL/min and 4 mL/min, respectively. Integration...... of soft magnetic elements in the chip leads to a slightly higher capturing efficiency and a more uniform distribution of captured beads over the separation chamber than the system without soft magnetic elements....

  2. Removal of organic dyes by magnetic alginate beads.

    Science.gov (United States)

    Rocher, Vincent; Siaugue, Jean-Michel; Cabuil, Valérie; Bee, Agnès

    2008-02-01

    This study deals with the development of a clean and safe process for water pollution remediation. We have synthesized a magnetic adsorbent in order to develop a solid-phase extraction process assisted by a magnetic field. To follow an 'ecoconception' approach, magnetic beads containing magnetic nanoparticles and activated carbon are prepared with a biopolymer extracted from algae, sodium alginate. The use of renewable bioresources of low cost and those disposable in large amount allows the development of a product with a low impact on the environment. The adsorption properties of activated carbon and magnetic properties of iron oxide nanoparticles are combined to produce an interesting magnetic composite. Synthesis and characterization of the magnetic beads have been reported. Their adsorption capacity was investigated by measuring the removal of two dyes (methylene blue and methyl orange) of different charges from aqueous solutions. The efficiency of the beads has been compared with that of non-encapsulated activated carbon. The effects of initial dye concentration, pH and calcium content of the beads have been studied. Adsorption kinetics experiments have been carried out and the data have been well fitted by a pseudo-second-order equation.

  3. Magnetic measurements of suspended functionalised ferromagnetic beads under DC applied fields

    International Nuclear Information System (INIS)

    De Los Santos V, Luis; Llandro, Justin; Lee, Dongwook; Mitrelias, Thanos; Palfreyman, Justin J.; Hayward, Thomas J.; Cooper, Jos; Bland, J.A.C.; Barnes, Crispin H.W.; Arroyo C, Juan L.; Lees, Martin

    2009-01-01

    In this work, a simple technique to obtain the hysteresis loops of magnetic beads (Spherotech Inc.) in liquid suspension is presented. The magnetic measurements were taken in a DC Magnetic Property Measurement System (MPMS-SQUID sensor). Samples were based on ferromagnetic beads (surface-functionalized NH 2 , mean diameter 4.32 μm) prepared in three conditions: dry, suspended in sucrose solution and in suspension after functionalization with fluorophore. Special small containers (1.3 cm long) made of non magnetic plastic were designed to hold the beads in liquid. The results indicate that the bead's remnant magnetization is half of the value at maximum applied field in all cases. However, due to the additional degrees of rotational freedom, beads suspended in a liquid do not present coercivity. The use of ferromagnetic beads and magnetic elements of different architectures for applications in bioassays is also discussed.

  4. Planar Hall effect sensor bridge geometries optimized for magnetic bead detection

    DEFF Research Database (Denmark)

    Østerberg, Frederik Westergaard; Rizzi, Giovanni; Henriksen, Anders Dahl

    2014-01-01

    Novel designs of planar Hall effect bridge sensors optimized for magnetic bead detection are presented and characterized. By constructing the sensor geometries appropriately, the sensors can be tailored to be sensitive to an external magnetic field, the magnetic field due to beads being magnetized...... by the sensor self-field or a combination thereof. The sensors can be made nominally insensitive to small external magnetic fields, while being maximally sensitive to magnetic beads, magnetized by the sensor self-field. Thus, the sensor designs can be tailored towards specific applications with minimal...... of the dynamic magnetic response of suspensions of magnetic beads with a nominal diameter of 80 nm are performed. Furthermore, a method to amplify the signal by appropriate combinations of multiple sensor segments is demonstrated....

  5. Effects of Magnetic Particles Entrance Arrangements on Mixing Efficiency of a Magnetic Bead Micromixer

    Institute of Scientific and Technical Information of China (English)

    Reza Kamali; Seyed Alireza Shekoohi; Alireza Binesh

    2014-01-01

    In this study, a computer code is developed to numerically investigate a magnetic bead micromixer under different conditions. The micromixer consists of a microchannel and numerous micro magnetic particles which enter the micromixer by fluid flows and are actuated by an alternating magnetic field normal to the main flow. An important feature of micromixer which is not considered before by researchers is the particle entrance arrangement into the micromixer. This parameter could effectively affect the micromixer efficiency. There are two general micro magnetic particle entrance arrangements in magnetic bead micromixers: determined position entrance and random position entrance. In the case of determined position entrances, micro magnetic particles enter the micromixer at specific positions of entrance cross section. However, in a random position entrance,particles enter the microchannel with no order. In this study mixing efficiencies of identical magnetic bead micromixers which only differ in particle entrance arrangement are numerically investigated and compared.The results reported in this paper illustrate that the prepared computer code can be one of the most powerful and beneficial tools for the magnetic bead micromixer performance analysis. In addition, the results show that some features of the magnetic bead micromixer are strongly affected by the entrance arrangement of the particles.

  6. Theoretical study of in-plane response of magnetic field sensor to magnetic beads in an in-plane homogeneous field

    DEFF Research Database (Denmark)

    Damsgaard, Christian Danvad; Hansen, Mikkel Fougt

    2008-01-01

    We present a systematic theoretical study of the average in-plane magnetic field on square and rectangular magnetic field sensors from a single magnetic bead and a monolayer of magnetic beads magnetized by an in-plane externally applied homogeneous magnetic field. General theoretical expressions...... are derived such that the sensor response and its dependence on the sensor size, spacer layer thickness, bead diameter, and bead susceptibility can easily be evaluated. The average magnetic field from a single bead close to the sensor shows a strong dependence on the position of the bead and a change of sign...... when the bead passes the edge of the sensor in the direction of the applied field. Analytical approximations are derived for the average field from a homogeneous monolayer of beads for beads much smaller than the sensor dimension and for a bead size chosen to minimize the position sensitivity...

  7. An approach to implement virtual channels for flowing magnetic beads

    International Nuclear Information System (INIS)

    Tang, Shih-Hao; Chiang, Hung-Wei; Hsieh, Min-Chien; Chang, Yen-Di; Yeh, Po-Fan; Tsai, Jui-che; Shieh, Wung-Yang

    2014-01-01

    This work demonstrates the feasibility of a novel microfluidic system with virtual channels formed by ‘walls’ of magnetic fields, including collecting channels, transporting channels and function channels. The channels are defined by the nickel patterns. With its own ferromagnetism, nickel can be magnetized using an external magnetic field; the nickel structures then generate magnetic fields that can either guide or trap magnetic beads. A glass substrate is sandwiched between the liquid containing magnetic beads and the chip with nickel structures, preventing the liquid from directly contacting the nickel. In this work, collecting channels, transporting channels and function channels are displayed sequentially. In the collecting channel portion, channels with different shapes are compared. Next, in the transporting channel portion we demonstrate I-, S- and Y-shaped channels can steer magnetic beads smoothly. Finally, in the function channel portion, a switchable trapping channel implemented with a bistable mechanism performs the passing and blocking of a magnetic bead. (paper)

  8. Influence of Immobilized Biomolecules on Magnetic Bead Plug Formation and Retention in Capillary Electrophoresis

    Science.gov (United States)

    Henken, Rachel L.; Chantiwas, Rattikan; Gilman, S. Douglass

    2012-01-01

    Significant changes in the formation and retention of magnetic bead plugs in a capillary during electrophoresis were studied, and it was demonstrated that these effects were due to the type of biological molecule immobilized on the surface of these beads. Three biological molecules, an antibody, an oligonucleotide and alkaline phosphatase, were attached to otherwise identical streptavidin-coated magnetic beads through biotin-avidin binding in order to isolate differences in bead immobilization in a magnetic field resulting from the type of biological molecule immobilized on the bead surface. Alkaline phosphatase also was attached to the magnetic beads using epoxy groups on the bead surfaces (instead of avidin-biotin binding) to study the impact of immobilization chemistry. The formation and retention of magnetic bead plugs were studied quantitatively using light scattering detection of magnetic particles eluting from the bead plugs and qualitatively using microscopy. Both the type of biomolecule immobilized on the magnetic bead surface and the chemistry used to link the biomolecule to the magnetic bead impacted the formation and retention of the bead plugs. PMID:22437880

  9. Towards a programmable magnetic bead microarray in a microfluidic channel

    DEFF Research Database (Denmark)

    Smistrup, Kristian; Bruus, Henrik; Hansen, Mikkel Fougt

    2007-01-01

    to use larger currents and obtain forces of longer range than from thin current lines at a given power limit. Guiding of magnetic beads in the hybrid magnetic separator and the construction of a programmable microarray of magnetic beads in the microfluidic channel by hydrodynamic focusing is presented....

  10. Liquid carry-over in an injection moulded all-polymer chip system for immiscible phase magnetic bead-based solid-phase extraction

    Science.gov (United States)

    Kistrup, Kasper; Skotte Sørensen, Karen; Wolff, Anders; Fougt Hansen, Mikkel

    2015-04-01

    We present an all-polymer, single-use microfluidic chip system produced by injection moulding and bonded by ultrasonic welding. Both techniques are compatible with low-cost industrial mass-production. The chip is produced for magnetic bead-based solid-phase extraction facilitated by immiscible phase filtration and features passive liquid filling and magnetic bead manipulation using an external magnet. In this work, we determine the system compatibility with various surfactants. Moreover, we quantify the volume of liquid co-transported with magnetic bead clusters from Milli-Q water or a lysis-binding buffer for nucleic acid extraction (0.1 (v/v)% Triton X-100 in 5 M guanidine hydrochloride). A linear relationship was found between the liquid carry-over and mass of magnetic beads used. Interestingly, similar average carry-overs of 1.74(8) nL/μg and 1.72(14) nL/μg were found for Milli-Q water and lysis-binding buffer, respectively.

  11. On-chip measurement of the Brownian relaxation frequency of magnetic beads using magnetic tunneling junctions

    DEFF Research Database (Denmark)

    Donolato, M.; Sogne, E.; Dalslet, Bjarke Thomas

    2011-01-01

    We demonstrate the detection of the Brownian relaxation frequency of 250 nm diameter magnetic beads using a lab-on-chip platform based on current lines for exciting the beads with alternating magnetic fields and highly sensitive magnetic tunnel junction (MTJ) sensors with a superparamagnetic free...

  12. Liquid carry-over in an injection moulded all-polymer chip system for immiscible phase magnetic bead-based solid-phase extraction

    Energy Technology Data Exchange (ETDEWEB)

    Kistrup, Kasper, E-mail: kkis@nanotech.dtu.dk [Department of Micro- and Nanotechnology, Technical University of Denmark, DTU Nanotech, Building 345 East, DK-2800 Kongens Lyngby (Denmark); Skotte Sørensen, Karen, E-mail: karen@nanotech.dtu.dk [Department of Micro- and Nanotechnology, Technical University of Denmark, DTU Nanotech, Building 345 East, DK-2800 Kongens Lyngby (Denmark); Center for Integrated Point of Care Technologies (CiPoC), DELTA, Venlighedsvej 4, DK-2870 Hørsholm (Denmark); Wolff, Anders, E-mail: anders.wolff@nanotech.dtu.dk [Department of Micro- and Nanotechnology, Technical University of Denmark, DTU Nanotech, Building 345 East, DK-2800 Kongens Lyngby (Denmark); Fougt Hansen, Mikkel, E-mail: mikkel.hansen@nanotech.dtu.dk [Department of Micro- and Nanotechnology, Technical University of Denmark, DTU Nanotech, Building 345 East, DK-2800 Kongens Lyngby (Denmark)

    2015-04-15

    We present an all-polymer, single-use microfluidic chip system produced by injection moulding and bonded by ultrasonic welding. Both techniques are compatible with low-cost industrial mass-production. The chip is produced for magnetic bead-based solid-phase extraction facilitated by immiscible phase filtration and features passive liquid filling and magnetic bead manipulation using an external magnet. In this work, we determine the system compatibility with various surfactants. Moreover, we quantify the volume of liquid co-transported with magnetic bead clusters from Milli-Q water or a lysis-binding buffer for nucleic acid extraction (0.1 (v/v)% Triton X-100 in 5 M guanidine hydrochloride). A linear relationship was found between the liquid carry-over and mass of magnetic beads used. Interestingly, similar average carry-overs of 1.74(8) nL/µg and 1.72(14) nL/µg were found for Milli-Q water and lysis-binding buffer, respectively. - Highlights: • We present an all-polymer mass producible passive filled microfluidic chip system. • Rapid system fabrication is obtained by injection moulding and ultrasonic welding. • The system is made for single-use nucleic acid extraction using magnetic beads. • We systematically map compatibility of the chip system with various surfactants. • We quantify the volume carry-over of magnetic beads in water and 0.1% triton-X solution.

  13. Liquid carry-over in an injection moulded all-polymer chip system for immiscible phase magnetic bead-based solid-phase extraction

    International Nuclear Information System (INIS)

    Kistrup, Kasper; Skotte Sørensen, Karen; Wolff, Anders; Fougt Hansen, Mikkel

    2015-01-01

    We present an all-polymer, single-use microfluidic chip system produced by injection moulding and bonded by ultrasonic welding. Both techniques are compatible with low-cost industrial mass-production. The chip is produced for magnetic bead-based solid-phase extraction facilitated by immiscible phase filtration and features passive liquid filling and magnetic bead manipulation using an external magnet. In this work, we determine the system compatibility with various surfactants. Moreover, we quantify the volume of liquid co-transported with magnetic bead clusters from Milli-Q water or a lysis-binding buffer for nucleic acid extraction (0.1 (v/v)% Triton X-100 in 5 M guanidine hydrochloride). A linear relationship was found between the liquid carry-over and mass of magnetic beads used. Interestingly, similar average carry-overs of 1.74(8) nL/µg and 1.72(14) nL/µg were found for Milli-Q water and lysis-binding buffer, respectively. - Highlights: • We present an all-polymer mass producible passive filled microfluidic chip system. • Rapid system fabrication is obtained by injection moulding and ultrasonic welding. • The system is made for single-use nucleic acid extraction using magnetic beads. • We systematically map compatibility of the chip system with various surfactants. • We quantify the volume carry-over of magnetic beads in water and 0.1% triton-X solution

  14. A planar conducting microstructure to guide and confine magnetic beads to a sensing zone

    KAUST Repository

    Gooneratne, Chinthaka Pasan

    2011-08-01

    A novel planar conducting microstructure is proposed to transport and confine magnetic micro/nano beads to a sensing zone. Manipulation and concentration of magnetic beads are achieved by employing square-shaped conducting micro-loops, with a few hundred nano-meters in thickness, arranged in a unique fashion. These microstructures are designed to produce high magnetic field gradients which are directly proportional to the force applied to manipulate the magnetic beads. Furthermore, the size of the microstructures allows greater maneuverability and control of magnetic beads than what could be achieved by permanent magnets. The aim of the microstructures is to guide magnetic beads from a large area and confine them to a smaller area where for example quantification would take place. Experiments were performed with different concentrations of 2 μm diameter magnetic beads. Experimental results showed that magnetic beads could be successfully guided and confined to the sensing zone. © 2011 Elsevier B.V. All rights reserved.

  15. Magnetization of large polystyrene peptide beads for capturing and expanding cancer cells

    International Nuclear Information System (INIS)

    Marik, Jan; Lau, D.H.; Song Aimin; Wang Xiaobing; Liu Ruiwu; Lam, K.S.

    2003-01-01

    A method is described for preparation of large magnetic polystyrene beads coupled with peptide ligands for surface receptors of lung cancer cells. We have demonstrated the feasibility of using these magnetic peptide beads for capturing and enriching lung cancer cells spiked into blood. These magnetic peptide beads potentially can be used to efficiently isolate cancer cells from body fluids

  16. Effects of Magnetic Particles Entrance Arrange-ments on Mixing Efficiency of a Magnetic Bead Micromixer

    Institute of Scientific and Technical Information of China (English)

    Reza Kamali∗; Seyed Alireza Shekoohi; Alireza Binesh

    2014-01-01

    In this study, a computer code is developed to numerically investigate a magnetic bead micromixer under different conditions. The micromixer consists of a microchannel and numerous micro magnetic particles which enter the micromixer by fluid flows and are actuated by an alternating magnetic field normal to the main flow. An important feature of micromixer which is not considered before by researchers is the particle entrance arrangement into the micromixer. This parameter could effectively affect the micromixer efficiency. There are two general micro magnetic particle entrance arrangements in magnetic bead micromixers: determined position entrance and random position entrance. In the case of determined position entrances, micro magnetic particles enter the micromixer at specific positions of entrance cross section. However, in a random position entrance, particles enter the microchannel with no order. In this study mixing efficiencies of identical magnetic bead micromixers which only differ in particle entrance arrangement are numerically investigated and compared. The results reported in this paper illustrate that the prepared computer code can be one of the most powerful and beneficial tools for the magnetic bead micromixer performance analysis. In addition, the results show that some features of the magnetic bead micromixer are strongly affected by the entrance arrangement of the particles.

  17. Aptamer-Modified Magnetic Beads in Biosensing

    Science.gov (United States)

    Scheper, Thomas; Walter, Johanna-Gabriela

    2018-01-01

    Magnetic beads (MBs) are versatile tools for the purification, detection, and quantitative analysis of analytes from complex matrices. The superparamagnetic property of magnetic beads qualifies them for various analytical applications. To provide specificity, MBs can be decorated with ligands like aptamers, antibodies and peptides. In this context, aptamers are emerging as particular promising ligands due to a number of advantages. Most importantly, the chemical synthesis of aptamers enables straightforward and controlled chemical modification with linker molecules and dyes. Moreover, aptamers facilitate novel sensing strategies based on their oligonucleotide nature that cannot be realized with conventional peptide-based ligands. Due to these benefits, the combination of aptamers and MBs was already used in various analytical applications which are summarized in this article. PMID:29601533

  18. Comparison between simulation and experimentally observed interactions between two magnetic beads in a fluidic system

    Energy Technology Data Exchange (ETDEWEB)

    Oduwole, Olayinka, E-mail: olayinka.oduwole@eng.ox.ac.uk; Grob, David Tim, E-mail: tim.grob@eng.ox.ac.uk; Sheard, Steve, E-mail: steve.sheard@eng.ox.ac.uk

    2016-06-01

    Continuous flow separation of magnetic particles within a microfluidic device could lead to improved performance of magnetic bead-based assays but the undesirable formation of bead clusters reduces its efficiency; this efficiency refers to the ability to separate bound magnetic beads from a mixture of particles. Such agglomerates are formed due to magnetic binding forces while hydrodynamic interactions strongly influence the particles' movement. This paper presents a model for interactions between a pair of equal sized super-paramagnetic beads suspended in water within a uniform magnetic field. To the best of our knowledge, we present for the first time a comparison between simulated trajectories and the beads' movement captured on video; the beads were suspended in a stationary fluid placed within a uniform magnetic field. In conclusion, the model is a good approximation for beads interacting with their nearest neighbours and is able to predict the trajectory pattern of these particles in a magnetic bead-based assay. Predicting the magnetically induced interaction of nearby beads will help in determining the density of beads in an assay and in avoiding agglomeration over a fixed time duration. - Highlights: • We modelled the interactions between a pair of super-paramagnetic beads suspended in water within a uniform magnetic field. • We tracked the movement of the bead pair and captured it on video. • We compared the numerical results with the video data and achieved a good agreement. • We predicted the agglomeration time as a function of the separation distance.

  19. Magnetic composite beads for sorption of cesium ions from aqueous streams

    International Nuclear Information System (INIS)

    Shinde, Rakesh N.; Pandey, A.K.; Acharya, R.; Rajurkar, N.S.

    2014-01-01

    Magnetic separation of metal ions is one of the promising methods due to simple, fast, efficient and cost effective technology. Highly selective magnetic sorbents can be designed by immobilizing functional groups in magnetic carrier which binds to the target specific ions. In the present work chitosan-(3-aminopropyl) triethoxysilane (APTS)- copperferrocyanide (CFC) composite beads have been synthesized for sorption of 137 Cs ions from aqueous streams. Physical characterization of the best resulted polymer beads was carried out by SEM-EDX and VSM technique. Sorption of Cs ions in the various magnetic polymer beads were studied in different aqueous condition by 137 Cs (662 KeV) radiotracer assay

  20. Polymerase chain reaction system using magnetic beads for analyzing a sample that includes nucleic acid

    Science.gov (United States)

    Nasarabadi, Shanavaz [Livermore, CA

    2011-01-11

    A polymerase chain reaction system for analyzing a sample containing nucleic acid includes providing magnetic beads; providing a flow channel having a polymerase chain reaction chamber, a pre polymerase chain reaction magnet position adjacent the polymerase chain reaction chamber, and a post pre polymerase magnet position adjacent the polymerase chain reaction chamber. The nucleic acid is bound to the magnetic beads. The magnetic beads with the nucleic acid flow to the pre polymerase chain reaction magnet position in the flow channel. The magnetic beads and the nucleic acid are washed with ethanol. The nucleic acid in the polymerase chain reaction chamber is amplified. The magnetic beads and the nucleic acid are separated into a waste stream containing the magnetic beads and a post polymerase chain reaction mix containing the nucleic acid. The reaction mix containing the nucleic acid flows to an analysis unit in the channel for analysis.

  1. Superparamagnetic beads in rotating magnetic fields: microfluidic experiments

    NARCIS (Netherlands)

    Den Toonder, J.M.J.; Bokdam, M.

    2008-01-01

    The effect of the Mason number, ratio of viscous and magnetic force, on suspended superparamagnetic micro sized beads was investigated experimentally. Microfluidic experiments were performed in a set-up that generates a rotating homogeneous magnetic field. In the presence of a magnetic field, the

  2. [DNA extraction from decomposed tissue by double-digest and magnetic beads methods].

    Science.gov (United States)

    Yang, Dian; Liu, Chao; Liu, Hong

    2011-12-01

    To study the effect of the double-digest and magnetic beads method for DNA extraction from 3 types of decomposed tissues. DNA of cartilages, nails and joint capsule in 91 highly decomposed corpses which had not been extracted by common magnetic beads method, were prepared with the double-digest and magnetic beads methods, and quantified with Quantifiler kit, followed by amplification with Sinofiler kit or Minifiler kit. DNA concentration extracted from the 91 highly decomposed cartilages, nails and joint capsule samples was 0-0.225 ng/microL. Sixty-two samples whose DNA concentration were more than 0.020 ng/microL had obtained 9 or more STR loci successfully. The detection rate was 68.13%. The successful rate of STR genotyping for the 3 types of decomposed tissues can be significantly improved by the double-digest and magnetic beads methods.

  3. Induced movement of the magnetic beads and DNA-based dumbbell in a micro fluidic channel

    Science.gov (United States)

    Babić, B.; Ghai, R.; Dimitrov, K.

    2007-12-01

    We have explored controlled movement of magnetic beads and a dumbbell structure composed of DNA, a magnetic and a non-magnetic bead in a micro fluidic channel. Movement of the beads and dumbbells is simulated assuming that a net force is described as a superposition between the magnetic and hydrodynamic drag forces. Trajectories of beads and dumbbells are observed with optical light microscopy. The experimentally measured data show a good agreement with the simulations. This dynamical approach offers the prospect to stretch the DNA within the dumbbell and investigate its conformational changes. Further on, we demonstrate that short sonication can reduce multiple attachments of DNA to the beads.

  4. Magnetic nanoparticle-loaded alginate beads for local micro-actuation of in vitro tissue constructs.

    Science.gov (United States)

    Alshehri, Awatef M; Wilson, Otto C; Dahal, Bishnu; Philip, John; Luo, Xiaolong; Raub, Christopher B

    2017-11-01

    Magnetic nanoparticles (MNPs) self-align and transduce magnetic force, two properties which lead to promising applications in cell and tissue engineering. However, the toxicity of MNPs to cells which uptake them is a major impediment to applications in engineered tissue constructs. To address this problem, MNPs were embedded in millimeter-scale alginate beads, coated with glutaraldehyde cross-linked chitosan, and loaded in acellular and MDA-MB-231 cancer cell-seeded collagen hydrogels, providing local micro-actuation under an external magnetic field. Brightfield microscopy was used to assess nanoparticle diffusion from the bead. Phase contrast microscopy and digital image correlation were used to track collagen matrix displacement and estimate intratissue strain under magnetic actuation. Coating the magnetic alginate beads with glutaraldehyde-chitosan prevents bulk diffusion of nanoparticles into the surrounding microenvironment. Further, the beads exert force on the surrounding collagen gel and cells, resulting in intratissue strains of 0-10% tunable with bead dimensions, collagen density, and distance from the bead. Cells seeded adjacent to the embedded beads are subjected to strain gradients without loss of cell viability over two days culture. This study describes a simple way to fabricate crosslinked magnetic alginate beads to load in a collagen tissue construct without direct exposure of the construct to nanoparticles. The findings are significant to in vitro studies of mechanobiology in enabling precise control over dynamic mechanical loading of tissue constructs. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Effect of patterned micro-magnets on superparamagnetic beads in microchannels

    International Nuclear Information System (INIS)

    Guo, S S; Deng, Y L; Zhao, L B; Zhao, X-Z; Chan, H L W

    2008-01-01

    The trapping response of patterned micro-magnets (PMMs) was studied based on the parameters affecting superparamagnetic beads in microfluidic channels. Using replica moulding and electroplating technologies, the PMMs were fabricated on the microchannel bottom, which generated sufficient magnetic forces to bias the moments of magnetic particles in a flowing stream. A simplified physical principle was used to analyse the relative velocity of the magnetic particle in the confined space of a microchannel. The results revealed that the magnetic force contributed to the fluidic flow rate as well as to the hydrodynamic drag force. The relative velocity of magnetic particles was dependent on the frequency under an external magnetic field driven by an alternate current (ac) source. It showed that the magnetic gradient induced hysteresis characteristics of the transmission spectrum, associated with the interaction of superparamagnetic beads and magnetic field

  6. On-chip measurements of Brownian relaxation vs. concentration of 40nm magnetic beads

    DEFF Research Database (Denmark)

    Østerberg, Frederik Westergaard; Rizzi, Giovanni; Hansen, Mikkel Fougt

    2012-01-01

    We present on-chip Brownian relaxation measurements on a logarithmic dilution series of 40 nm beads dispersed in water with bead concentrations between 16 mu g/ml and 4000 mu g/ml. The measurements are performed using a planar Hall effect bridge sensor at frequencies up to 1 MHz. No external fields...... are needed as the beads are magnetized by the field generated by the applied sensor bias current. We show that the Brownian relaxation frequency can be extracted from fitting the Cole-Cole model to measurements for bead concentrations of 64 mu g/ml or higher and that the measured dynamic magnetic response...... is proportional to the bead concentration. For bead concentrations higher than or equal to 500 mu g/ml, we extract a hydrodynamic diameter of 47(1) nm for the beads, which is close to the nominal bead size of 40 nm. Furthermore, we study the signal vs. bead concentration at a fixed frequency close to the Brownian...

  7. Method and device for thermal control of biological and chemical reactions using magnetic particles or magnetic beads and variable magnetic fields

    OpenAIRE

    Zilch, C.; Gerdes, W.; Bauer, J.; Holschuh, K.

    2009-01-01

    The invention relates to a method for the thermal control of at least one temperature-dependent enzymatic reaction in the presence of magnetic particles, particularly nanoparticles, or magnetic beads, in vitro by heating the magnetic beads or magnetic particles to at least one defined target temperature using alternating magnetic fields. The thermally controllable enzymatic reaction carried out with the method according to the invention is preferably a PCR reaction or another reaction for elo...

  8. Alginate/magnetite hybrid beads for magnetically stimulated release of dopamine.

    Science.gov (United States)

    Kondaveeti, Stalin; Cornejo, Daniel R; Petri, Denise Freitas Siqueira

    2016-02-01

    Hybrid beads composed of magnetite nanoparticles (MNP) and alginate (Alg) were synthesized and coded as Alg-MNP. They were incubated in dopamine (DOPA) solution (5 g/L), at pH 7.4 and 8 °C, during 12 h, promoting the DOPA loaded magnetic beads, coded as Alg-MNP/DOPA. The release of DOPA was further evaluated in the absence and the presence of external magnetic field (EMF) of 0.4 T. The products Alg-MNP and Alg-MNP/DOPA were characterized by scanning electron microscopy with energy dispersive spectroscopy (SEM-EDS), Fourier transform infrared vibrational spectroscopy (FTIR), UV spectrophotometry, thermogravimetric analyses (TGA), inductively coupled plasma atomic emission spectroscopy (ICP-AES) analyses and superconducting quantum interference device (SQUID) magnetometer. The magnetic and chemical properties of Alg-MNP beads were not affected by DOPA loading. The incorporation of DOPA into the beads depended on the pH and on the negative charge density. At pH 7.4 38% of DOPA were loaded into Alg-MNP beads, whereas at pH 2 or using neat Alg beads (lower charge density than Alg-MNP) the loading efficiency decreased to one third or less. In the absence of EMF, 24% of the loaded DOPA was released from Alg-MNP at pH 7.4 over a period of 26 h. The released amount increased to 33% under the stimulus of EMF. A model was proposed to explain the loading efficiency of charged drugs, as DOPA, into hybrid beads and the role played by EMF on delivery systems, where drug and matrix are oppositely charged. The results suggest that the alginate combined with magnetite nanoparticles is a promising system for release of DOPA in the presence of EMF. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. On-chip magnetic bead-based DNA melting curve analysis using a magnetoresistive sensor

    DEFF Research Database (Denmark)

    Rizzi, Giovanni; Østerberg, Frederik Westergaard; Henriksen, Anders Dahl

    2014-01-01

    We present real-time measurements of DNA melting curves in a chip-based system that detects the amount of surface-bound magnetic beads using magnetoresistive magnetic field sensors. The sensors detect the difference between the amount of beads bound to the top and bottom sensor branches....... The beads are magnetized by the field arising from the bias current passed through the sensors. We demonstrate the first on-chip measurements of the melting of DNA hybrids upon a ramping of the temperature. This overcomes the limitation of using a single washing condition at constant temperature. Moreover...

  10. On-chip measurements of Brownian relaxation of magnetic beads with diameters from 10 nm to 250 nm

    DEFF Research Database (Denmark)

    Østerberg, Frederik Westergaard; Rizzi, Giovanni; Hansen, Mikkel Fougt

    2013-01-01

    We demonstrate the use of planar Hall effect magnetoresistive sensors for AC susceptibility measurements of magnetic beads with frequencies ranging from DC to 1 MHz. This wide frequency range allows for measuring Brownian relaxation of magnetic beads with diameters ranging from 10 nm to 250 nm....... Brownian relaxation is measured for six different magnetic bead types and their hydrodynamic diameters are determined. The hydrodynamic diameters are found to be within 40% of the nominal bead diameters. We discuss the applicability of the different bead types for volume-based biosensing with respect...... to sedimentation, magnetic trapping, and signal per bead. Among the investigated beads, we conclude that the beads with a nominal diameter of 80 nm are best suited for future on-chip volume-based biosensing experiments using planar Hall effect sensors....

  11. Synthesis and characterization of monosize magnetic poly(glycidyl methacrylate) beads

    Institute of Scientific and Technical Information of China (English)

    Evrim Banu Alt1nta(s); Lokman Uzun; Adil Denizli

    2007-01-01

    Monosize, 1.6 μm, magnetic beads of poly(glycidyl methacrylate) [M-poly(GMA)], were prepared by dispersion polymerization in the presence of Fe3O4 nano-powder. Monosize M-poly(GMA) beads were characterized by swelling tests, density measurements, electron spin resonance (ESR), vibrating sample magnetometer (VSM) and scanning electron microscopy (SEM). The characteristic functional groups of M-poly(GMA)beads were analyzed by Fourier transform infrared spectrometer (FTIR). The M-poly(GMA) beads are highly uniform in size and have a spherical shape and non-porous structure. Polydispersity index (PDI) of M-poly(GMA) beads was calculated to be around 1.008. The hydrated density of the M-poly(GMA) beads measured at 25 ℃ was 1.14 g/cm3. The content of oxirane groups on the surface of the M-poly(GMA) sample was found to be 3.46 mmol/g by using perchloric acid titration. The specific surface area of the M-poly(GMA) beads was determined to be 3.2 m2/g.The equilibrium swelling ratio was 52%. The volume fraction of magnetite nanopowder in the M-poly(GMA) beads was found to be 4.5%. The g factor, that can be considered as a quantity characteristic of the molecules in which the unpaired electrons are located, was found to be 2.28for M-poly(GMA). The external magnetic field at resonance was calculated to be 2055 Gs which was found sufficient to excite all of the dipole moments present in 1.0 g of M-poly(GMA) sample.

  12. Selective manipulation of superparamagnetic beads by a magnetic microchip

    KAUST Repository

    Gooneratne, Chinthaka Pasan; Yassine, Omar; Giouroudi, Ioanna; Kosel, Jü rgen

    2013-01-01

    In this paper, a magnetic microchip (MMC) is presented, to first trap and then selectively manipulate individual, superparamagnetic beads (SPBs) to another trapping site. Trapping sites are realized through soft magnetic micro disks made of Ni80Fe20

  13. Use of magnetic beads for Gram staining of bacteria in aqueous suspension.

    Science.gov (United States)

    Yazdankhah, S P; Sørum, H; Larsen, H J; Gogstad, G

    2001-12-01

    A Gram staining technique was developed using monodisperse magnetic beads in concentrating bacteria in suspension for downstream application. The technique does not require heat fixation of organisms, electrical power, or a microscope. Gram-negative and Gram-positive bacteria were identified macroscopically based on the colour of the suspension. The bacteria concentrated on magnetic beads may also be identified microscopically.

  14. Liquid carry-over in an injection moulded all-polymer chip system for immiscible phase magnetic bead-based solid-phase extraction

    DEFF Research Database (Denmark)

    Kistrup, Kasper; Sørensen, Karen Skotte; Wolff, Anders

    2014-01-01

    We present an all-polymer, single-use microfluidic chip system produced by injection moulding and bonded by ultrasonic welding. Both techniques are compatible with low-cost industrial mass-production. The chip is produced for magnetic bead-based solid-phase extraction facilitated by immiscible......-binding buffer for nucleic acid extraction (0.1 (v/v)% Triton X-100 in 5 M guanidine hydrochloride). A linear relationship was found between the liquid carry-over and mass of magnetic beads used. Interestingly, similar average carry-overs of 1.74(8) nL/µg and 1.72(14) nL/µg were found for Milli-Q water and lysis...

  15. Magnetic chitosan/clay beads: A magsorbent for the removal of cationic dye from water

    Energy Technology Data Exchange (ETDEWEB)

    Bée, Agnès, E-mail: agnes.bee@upmc.fr [Sorbonne Universités, UPMC Univ Paris 06, CNRS, Laboratoire PHENIX, F-75005 Paris (France); Obeid, Layaly, E-mail: lghannoum@hotmail.fr [Sorbonne Universités, UPMC Univ Paris 06, CNRS, Laboratoire PHENIX, F-75005 Paris (France); CertiNergy Solutions, 33 avenue du Maine, BP 195, 75755 Paris Cedex 15 (France); Mbolantenaina, Rakotomalala, E-mail: mbolantenaina@yahoo.fr [Sorbonne Universités, UPMC Univ Paris 06, CNRS, Laboratoire PHENIX, F-75005 Paris (France); Welschbillig, Mathias, E-mail: welschbillig@certinergysolutions.com [CertiNergy Solutions, 33 avenue du Maine, BP 195, 75755 Paris Cedex 15 (France); Talbot, Delphine, E-mail: delphine.talbot@upmc.fr [Sorbonne Universités, UPMC Univ Paris 06, CNRS, Laboratoire PHENIX, F-75005 Paris (France)

    2017-01-01

    A magnetic composite material composed of magnetic nanoparticles and clay encapsulated in cross-linked chitosan beads was prepared, characterized and used as a magsorbent for the removal of a cationic dye, methylene blue (MB), from aqueous solutions. The magnetic properties of these beads represent an advantage to recover them at the end of the depollution process. The optimal weight ratio R=clay:chitosan for the removal of MB in a large range of pH was determined. For beads without clay, the maximal adsorption capacity of MB occurs in the pH range [9–12], while for beads with clay, the pH range extends by increasing the amount of clay to reach [3–12] for R>0.5. Adsorption isotherms show that the adsorption capacity of magnetic beads is equal to 82 mg/g. Moreover, the kinetics of dye adsorption is relatively fast since 50% of the dye is removed in the first 13 min for an initial MB concentration equal to 100 mg/L. The estimation of the number of adsorption sites at a given pH shows that the main driving force for adsorption of MB in a large range of pH is the electrostatic interaction between the positively charged dye and the permanent negative charges of clay. - Highlights: • A magsorbent based on magnetic nanoparticles and clay encapsulated in chitosan beads was prepared and characterized. • Clay played significant role for the removal of a cationic dye. • The magnetic beads exhibit a maximum adsorption capacity of 82 mg/g for methylene blue. • The pH range of the maximum adsorption extends from [9–12] to [3–12] by increasing the amount of clay. • The magsorbent could be magnetically removed from solution.

  16. "On-chip magnetic bead microarray using hydrodynamic focusing in a passive magnetic separator"

    DEFF Research Database (Denmark)

    Smistrup, Kristian; Kjeldsen, B.; Reimers, R.L.

    2005-01-01

    Implementing DNA and protein microarrays into lab-on-a-chip systems can be problematic since these are sensitive to heat and strong chemicals. Here, we describe the functionalization of a microchannel with two types of magnetic beads using hydrodynamic focusing combined with a passive magnetic...

  17. Magnetic actuator for the control and mixing of magnetic bead-based reactions on-chip.

    Science.gov (United States)

    Berenguel-Alonso, Miguel; Granados, Xavier; Faraudo, Jordi; Alonso-Chamarro, Julián; Puyol, Mar

    2014-10-01

    While magnetic bead (MB)-based bioassays have been implemented in integrated devices, their handling on-chip is normally either not optimal--i.e. only trapping is achieved, with aggregation of the beads--or requires complex actuator systems. Herein, we describe a simple and low-cost magnetic actuator to trap and move MBs within a microfluidic chamber in order to enhance the mixing of a MB-based reaction. The magnetic actuator consists of a CD-shaped plastic unit with an arrangement of embedded magnets which, when rotating, generate the mixing. The magnetic actuator has been used to enhance the amplification reaction of an enzyme-linked fluorescence immunoassay to detect Escherichia coli O157:H7 whole cells, an enterohemorrhagic strain, which have caused several outbreaks in food and water samples. A 2.7-fold sensitivity enhancement was attained with a detection limit of 603 colony-forming units (CFU) /mL, when employing the magnetic actuator.

  18. One-step isolation of plasma membrane proteins using magnetic beads with immobilized concanavalin A

    DEFF Research Database (Denmark)

    Lee, Yu-Chen; Block, Gregory; Chen, Huiwen

    2008-01-01

    We have developed a simple method for isolating and purifying plasma membrane proteins from various cell types. This one-step affinity-chromatography method uses the property of the lectin concanavalin A (ConA) and the technique of magnetic bead separation to obtain highly purified plasma membrane...... proteins from crude membrane preparations or cell lines. ConA is immobilized onto magnetic beads by binding biotinylated ConA to streptavidin magnetic beads. When these ConA magnetic beads were used to enrich plasma membranes from a crude membrane preparation, this procedure resulted in 3.7-fold enrichment...... of plasma membrane marker 5'-nucleotidase activity with 70% recovery of the activity in the crude membrane fraction of rat liver. In agreement with the results of 5'-nucleotidase activity, immunoblotting with antibodies specific for a rat liver plasma membrane protein, CEACAM1, indicated that CEACAM1...

  19. Applied Study on Magnetic Nanometer Beads in Preparation of Genechip Samples

    Institute of Scientific and Technical Information of China (English)

    陈慧; 高华方; 谢欣; 马雪梅; 杨渝珍

    2004-01-01

    Summary: A protocol for enrichment and adsorption of karyocyte from whole blood by using magnetic nanometer beads as solid-phase absorbents was presented. The PCR amplification could be accomplished by using the nanobeads with karyocyte as template directly and the PCR products were applied on an oligonucleotide array to do gene typing. The HLA-A PCR amplification system and a small HLA-A oligonucleotide microarray were applied as the platform and an experiment protocol of separating karyocyte from whole blood using the magnetic nanometer beads (Fe2O3) were set up.The experimental conditions were also discussed. It showed that pH level of PBS eluent, Taq enzyme quantity and fragment length of products could influent the amplification results, and the magnetic nano-beads could succeed in sample preparation in microarray to provide a promising way in automatic detection and lab-on-a-chip.

  20. Removal of diethyl phthalate from aqueous phase using magnetic poly(EGDMA-VP) beads

    Energy Technology Data Exchange (ETDEWEB)

    Tuemay Oezer, Elif [Department of Chemistry, Uludag University, Bursa (Turkey); Osman, Bilgen, E-mail: bilgeno@uludag.edu.tr [Department of Chemistry, Uludag University, Bursa (Turkey); Kara, Ali; Besirli, Necati; Guecer, Seref [Department of Chemistry, Uludag University, Bursa (Turkey); Soezeri, Hueseyin [TUBITAK-UME, National Metrology Institute, PO Box 54 TR-41470, Gebze/Kocaeli (Turkey)

    2012-08-30

    Highlights: Black-Right-Pointing-Pointer Magnetic beads were prepared for removal of diethyl phthalate (DEP). Black-Right-Pointing-Pointer Total capacity of the beads was determined as 98.9 mg DEP per gram polymer. Black-Right-Pointing-Pointer Magnetic beads were regenerated easily and reused for DEP adsorption. Black-Right-Pointing-Pointer Adsorption isotherms, kinetics and thermodynamics were elucidated. - Abstract: The barium hexaferrite (BaFe{sub 12}O{sub 19}) containing magnetic poly(ethylene glycol dimethacrylate-vinyl pyridine), (mag-poly(EGDMA-VP)) beads (average diameter = 53-212 {mu}m) were synthesized and characterized. Their use as an adsorbent in the removal of diethyl phthalate (DEP) from an aqueous solution was investigated. The mag-poly(EGDMA-VP) beads were prepared by copolymerizing of 4-vinyl pyridine (VP) with ethylene glycol dimethacrylate (EGDMA). The mag-poly(EGDMA-VP) beads were characterized by N{sub 2} adsorption/desorption isotherms (BET), vibrating sample magnetometer (VSM), X-ray powder diffraction (XRD), elemental analysis, scanning electron microscope (SEM) and swelling studies. At a fixed solid/solution ratio, the various factors affecting the adsorption of DEP from aqueous solutions such as pH, initial concentration, contact time and temperature were analyzed. The maximum DEP adsorption capacity of the mag-poly(EGDMA-VP) beads was determined as 98.9 mg/g at pH 3.0, 25 Degree-Sign C. All the isotherm data can be fitted with both the Langmuir and the Dubinin-Radushkevich isotherm models. The pseudo first-order, pseudo-second-order, Ritch-second-order and intraparticle diffusion models were used to describe the adsorption kinetics. The thermodynamic parameters obtained indicated the exothermic nature of the adsorption. The DEP adsorption capacity did not change after 10 batch successive reactions, demonstrating the usefulness of the magnetic beads in applications.

  1. A Phos-tag-based magnetic-bead method for rapid and selective separation of phosphorylated biomolecules.

    Science.gov (United States)

    Tsunehiro, Masaya; Meki, Yuma; Matsuoka, Kanako; Kinoshita-Kikuta, Emiko; Kinoshita, Eiji; Koike, Tohru

    2013-04-15

    A simple and efficient method based on magnetic-bead technology has been developed for the separation of phosphorylated and nonphosphorylated low-molecular-weight biomolecules, such as nucleotides, phosphorylated amino acids, or phosphopeptides. The phosphate-binding site on the bead is an alkoxide-bridged dinuclear zinc(II) complex with 1,3-bis(pyridin-2-ylmethylamino)propan-2-olate (Phos-tag), which is linked to a hydrophilic cross-linked agarose coating on a magnetic core particle. All steps for the phosphate-affinity separation are conducted in buffers of neutral pH with 50 μL of the magnetic beads in a 1.5-mL microtube. The entire separation protocol for phosphomonoester-type compounds, from addition to elution, requires less than 12 min per sample if the buffers and the zinc(II)-bound Phos-tag magnetic beads have been prepared in advance. The phosphate-affinity magnetic beads are reusable at least 15 times without a decrease in their phosphate-binding ability and they are stable for three months in propan-2-ol. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Chip-Based Measurements of Brownian Relaxation of Magnetic Beads Using a Planar Hall Effect Magnetic Field Sensor

    DEFF Research Database (Denmark)

    Østerberg, Frederik Westergaard; Dalslet, Bjarke Thomas; Snakenborg, Detlef

    2010-01-01

    using only the self-field arising from the bias current applied to the sensors as excitation field. We present measurements on a suspension of magnetic beads with a nominal diameter of 250 nm vs. temperature and find that the observations are consistent with the Cole-Cole model for Brownian relaxation...... with a constant hydrodynamic bead diameter when the temperature dependence of the viscosity of water is taken into account. These measurements demonstrate the feasibility of performing measurements of the Brownian relaxation response in a lab-on-a-chip system and constitute the first step towards an integrated...... biosensor based on the detection of the dynamic response of magnetic beads....

  3. Antibody-integrated and functionalized graphite-encapsulated magnetic beads, produced using ammonia gas plasma technology, for capturing Salmonella.

    Science.gov (United States)

    Sakudo, Akikazu; Chou, Han; Nagatsu, Masaaki

    2015-03-01

    Salmonella spp. is the single and most important causative agent of foodborne infections, especially involving foods such as eggs, milk and meat. To prevent infection, a reliable surveillance system is required that can quickly and sensitively detect Salmonella. Here, we describe the development of antibody-integrated magnetic beads that are functionalized by a novel strategy using ammonia gas plasma. Ammonia plasma, produced by a radio frequency (RF) power supply, was allowed to react with the surface of graphite-encapsulated magnetic beads, resulting in the introduction of amino groups. An anti-Salmonella antibody was then anchored by sulfide groups present on the protein surface to the amino groups of the magnetic beads via N-succinimidyl 3-(2-pyridyldithio) propionate (SPDP). The potential usefulness of these magnetic beads for capturing Salmonella was examined as follows. The beads were incubated with Salmonella in liquid medium and then separated from the supernatant by applying a magnetic field. After thorough washing, adsorption of Salmonella to the beads was confirmed by immunochromatography, polymerase chain reaction and a direct culture assay. Our findings indicate that the capture and concentration of Salmonella using the antibody-integrated magnetic beads was more efficient than commercial Dynabeads® anti-Salmonella, which are conventionally used for concentrating Salmonella from liquid cultures. We believe this novel bead technology will contribute to the enhanced detection of Salmonella. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Ultra-sensitive chemiluminescent detection of Staphylococcus aureus based on competitive binding of Staphylococcus protein A-modified magnetic beads to immunoglobulin G

    International Nuclear Information System (INIS)

    Xiong, Jie; Wang, Wenwen; Zhou, Yali; Kong, Weijun; Wang, Zhenxing; Fu, Zhifeng

    2016-01-01

    Staphylococcus protein A (SPA) is a surface protein only expressed naturally in the cell walls of Staphylococcus aureus (S. aureus) and binds specifically to the Fc region of immunoglobulin G (IgG). This fact can be utilized for the detection of S. aureus. Specifically, SPA-modified magnetic beads, compete with S. aureus pathogens for binding to rabbit IgG that previously was labeled with horseradish peroxidase (HRP). The beads were then magnetically separated, and chemiluminescence (CL) was generated by adding the reagents luminol and H_2O_2. Under optimal conditions, the intensity of CL decreases with increasing concentration of S. aureus over a very wide linear range (10 to 1.0 × 10"9 cfu·mL"−"1), with a limit of detection of 6.0 cfu·mL"−"1 at an S/N ratio of 3. The assay (including binding reaction, magnetic separation, washing of beads and detection) is completed within 50 min which is faster than many reported methods. It can well distinguish S. aureus from other Gram-positive and Gram-negative bacteria. The magnetic beads have the beneficial effect of eliminating undesired matrix effects and of concentrating the sample. The method was applied to the analysis of urine, apple juice and glucose injection samples spiked with S. aureus, and recoveries ranged from 85 to 107 %. (author)

  5. An integrated open-cavity system for magnetic bead manipulation.

    Science.gov (United States)

    Abu-Nimeh, F T; Salem, F M

    2013-02-01

    Superparamagnetic beads are increasingly used in biomedical assays to manipulate, transport, and maneuver biomaterials. We present a low-cost integrated system designed in bulk CMOS to manipulate and separate biomedical magnetic beads. The system consists of 8 × 8 coil-arrays suitable for single bead manipulation, or collaborative multi-bead manipulation, using pseudo-parallel executions. We demonstrate the flexibility of the design in terms of different coil sizes, DC current levels, and layout techniques. In one array module example, the size of a single coil is 30 μm × 30 μm and the full array occupies an area of 248 μm × 248 μm in 0.5 μm CMOS technology. The programmable DC current source supports 8 discrete levels up to 1.5 mA. The total power consumption of the entire module is 9 mW when running at full power.

  6. A half-ring GMR sensor for detection of magnetic beads immobilized on a circular micro-trap

    KAUST Repository

    Gooneratne, Chinthaka Pasan

    2011-11-01

    Utilizing magnetic principles in biological immunoassays is an attractive option given its ability to remotely and non-invasively manipulate and detect cells tagged with micro/nano size superparamagnetic type beads and due to the fact that even the most complex biological immunoassays will have very little magnetic effect. The presence of magnetic beads can be detected by a magnetic sensor which quantifies the amount of target cells present in the immunoassay. In order to increase the detection rate a circular conducting micro-trap is employed to attract, trap and transport the magnetic beads to the sensing area. In this research we propose a half-ring spin valve type giant magnetoresistance (GMR) sensor for the measurement of stray fields produced by 2 μm magnetic beads which are around the circular micro-trap. A couple of half-ring GMR sensors can be used to cover the entire circular border width, in order to detect the majority of the immobilized magnetic beads. Analytical and numerical analysis leading towards the fabrication of the half-ring GMR sensor are presented. DC characterization of the fabricated sensor showed a magnetoresistance of 5.9 %. Experimental results showed that the half-ring GMR sensor detected the presence of 2 μm magnetic beads. Hence, half-ring GMR sensors integrated with a circular micro-trap have great potential to be used as an effective disease diagnostic device. © 2011 IEEE.

  7. A half-ring GMR sensor for detection of magnetic beads immobilized on a circular micro-trap

    KAUST Repository

    Gooneratne, Chinthaka Pasan; Liang, Cai; Useinov, Arthur; Kosel, Jü rgen; Giouroudi, Ioanna

    2011-01-01

    Utilizing magnetic principles in biological immunoassays is an attractive option given its ability to remotely and non-invasively manipulate and detect cells tagged with micro/nano size superparamagnetic type beads and due to the fact that even the most complex biological immunoassays will have very little magnetic effect. The presence of magnetic beads can be detected by a magnetic sensor which quantifies the amount of target cells present in the immunoassay. In order to increase the detection rate a circular conducting micro-trap is employed to attract, trap and transport the magnetic beads to the sensing area. In this research we propose a half-ring spin valve type giant magnetoresistance (GMR) sensor for the measurement of stray fields produced by 2 μm magnetic beads which are around the circular micro-trap. A couple of half-ring GMR sensors can be used to cover the entire circular border width, in order to detect the majority of the immobilized magnetic beads. Analytical and numerical analysis leading towards the fabrication of the half-ring GMR sensor are presented. DC characterization of the fabricated sensor showed a magnetoresistance of 5.9 %. Experimental results showed that the half-ring GMR sensor detected the presence of 2 μm magnetic beads. Hence, half-ring GMR sensors integrated with a circular micro-trap have great potential to be used as an effective disease diagnostic device. © 2011 IEEE.

  8. On-Chip Manipulation of Protein-Coated Magnetic Beads via Domain-Wall Conduits

    DEFF Research Database (Denmark)

    Donolato, Marco; Vavassori, Paolo; Gobbi, Marco

    2010-01-01

    Geometrically constrained magnetic domain walls (DWs) in magnetic nanowires can be manipulated at the nanometer scale. The inhomogeneous magnetic stray field generated by a DW can capture a magnetic nanoparticle in solution. On-chip nanomanipulation of individual magnetic beads coated with proteins...

  9. Acetylcholinesterase immobilized capillary reactors coupled to protein coated magnetic beads: A new tool for plant extract ligand screening

    Science.gov (United States)

    Vanzolini, Kenia Lourenço; Jiang, Zhengjin; Zhang, Xiaoqi; Vieira, Lucas Campos Curcino; Corrêa, Arlene Gonçalvez; Cardoso, Carmen Lucia; Cass, Quezia Bezerra; Moaddel, Ruin

    2013-01-01

    The use of immobilized capillary enzyme reactors (ICERs) and enzymes coated to magnetic beads ((NT or CT)-MB) for ligand screening has been adopted as a new technique of high throughput screening (HTS). In this work the selected target was the enzyme acetylcholinesterase (AChE), which acts on the central nervous system and is a validated target for the treatment of Alzheimer’s disease, as well as for new insecticides. A new approach for the screening of plant extracts was developed based on the ligand fishing experiments and zonal chromatography. For that, the magnetic beads were used for the ligand fishing experiments and capillary bioreactors for the activity assays. The latter was employed also under non-linear conditions to determine the affinity constants of known ligands, for the first time, as well as for the active fished ligand. PMID:24148457

  10. Synthesis and Characterisation of Biocompatible Polymer-Conjugated Magnetic Beads for Enhancement Stability of Urease.

    Science.gov (United States)

    Doğaç, Yasemin Ispirli; Teke, Mustafa

    2016-04-01

    We reported natural polymer-conjugated magnetic featured urease systems for removal of urea effectively. The optimum temperature (20-60 °C), optimum pH (3.0-10.0), kinetic parameters, thermal stability (4-70 °C), pH stability (4.0-9.0), operational stability (0-250 min), reusability (18 times) and storage stability (24 weeks) were studied for characterisation of the urease-encapsulated biocompatible polymer-conjugated magnetic beads. Also, the surface groups and chemical structure of the magnetic beads were determined by using attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FTIR). The all urease-encapsulated magnetic beads protected their stability of 30-45 % relative activity at 70 °C. A significant increase was observed at their pH stability compared with the free urease for both acidic and alkaline medium. Besides this, their repeatability activity were approximately 100 % during 4(th) run. They showed residual activity of 50 % after 16 weeks. The importance of this work is enhancement stability of immobilised urease by biocompatible polymer-conjugated magnetic beads for the industrial application based on removal of urea.

  11. Binding kinetics of magnetic nanoparticles on latex beads and yeast cells studied by magnetorelaxometry

    International Nuclear Information System (INIS)

    Eberbeck, Dietmar; Bergemann, Christian; Hartwig, Stefan; Steinhoff, Uwe; Trahms, Lutz

    2005-01-01

    The ion exchange mediated binding of magnetic nanoparticles (MNP) to modified latex spheres and yeast cells was quantified using magnetorelaxometry. By fitting subsequently recorded relaxation curves, the kinetics of the binding reactions was extracted. The signal of MNP with weak ion exchanger groups bound to latex and yeast cells scales linearly with the concentration of latex beads or yeast cells whereas that of MNP with strong ion exchanger groups is proportional to the square root of concentration. The binding of the latter leads to a much stronger aggregation of yeast cells than the former MNP

  12. Electrochemical biotin detection based on magnetic beads and a new magnetic flow cell for screen printed electrode.

    Science.gov (United States)

    Biscay, Julien; González García, María Begoña; Costa García, Agustín

    2015-01-01

    The use of the first flow-cell for magnetic assays with an integrated magnet is reported here. The flow injection analysis system (FIA) is used for biotin determination. The reaction scheme is based on a one step competitive assay between free biotin and biotin labeled with horseradish peroxidase (B-HRP). The mixture of magnetic beads modified with streptavidin (Strep-MB), biotin and B-HRP is left 15 min under stirring and then a washing step is performed. After that, 100 μL of the mixture is injected and after 30s 100 μL of 3,3',5,5'-Tetramethylbenzidine (TMB) is injected and the FIAgram is recorded applying a potential of -0.2V. The linear range obtained is from 0.01 to 1 nM of biotin and the sensitivity is 758 nA/nM. The modification and cleaning of the electrode are performed in an easy way due to the internal magnet of the flow cell. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Preparation of Immuno-magnetic Beads and Their Separation & Detection to Ovary Cancer Cells

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The organic monomer-molecule with nanometer magnetic powder by means of reforming the surface of nanometer magnetic powder have been synthesized.Magnetic beads in diameter of 2μm or so are obtained by controlling conditions.Ovary cancer cells of ascites are separated and ovary cancer cells of blood are detected by using immuno-magnetic beads linked with ovary cancer cell mono-antibodies.Results show that the specificity is 85%,sensitivity is 87%,accuracy is 84%,cells acquiring purity is 90%,cells activity is 92% and detection sensitivity is 25×10-7.

  14. Caffeine: A novel green precursor for synthesis of magnetic CoFe2O4 nanoparticles and pH-sensitive magnetic alginate beads for drug delivery.

    Science.gov (United States)

    Amiri, Mahnaz; Salavati-Niasari, Masoud; Pardakhty, Abbas; Ahmadi, Meysam; Akbari, Ahmad

    2017-07-01

    Hydrogel beads are promising delivery systems for encapsulation and release of drugs due to the mild process of their fabrication from biopolymers. Magnetic CoFe 2 O 4 nanoparticles (MCFO, 9.72nm in diameter) were synthesized via a co-precipitation method using caffeine as a new environmentally friendly material in order to alkalinize the medium. Drug-targeting Magnetic beads based on CoFe 2 O 4 nanoparticles, sodium alginate and chlorpheniramine maleate (CPAM) were synthesized in the presence of Ca 2+ ions to obtain ionic cross-linked magnetic hydrogel beads. Nanoparticles as well as produced magnetic beads were thoroughly characterized by FTIR, XRD, SEM, nanosizer and VSM techniques. The swelling ratio of beads indicated pH-dependent property with maximum water absorbing at pH7.4. The in vitro release of beads exhibited significant behavior on the subject of nanoparticles concentration and alginate content. Biocompatibility of the CFO nanoparticles and MCFO/Alg beads are demonstrated through cytotoxicity test via MTT assay on U87 cell lines. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Rapid and reagent-saving immunoassay using innovative stirring actions of magnetic beads in microreactors in the sequential injection mode.

    Science.gov (United States)

    Tanaka, K; Imagawa, H

    2005-12-15

    We developed new ELISA techniques in sequential injection analysis (SIA) mode using microreactors with content of a few microliters. We immobilized antibodies on magnetic beads 1.0mum in diameter, injected the beads into microreactors and applied rotating magnetic fields of several hundred gauss. Magnetic beads, suspended in liquid in density of approximately 10(9)-10(10) particles per millilitre, form a large number of thin rod clusters, whose length-wise axes are oriented in parallel with the magnetic field. We rotate the Nd magnets below the center of the microreactor by a tiny motor at about 2000-5000rpm. These rotating clusters remarkably accelerate the binding rate of the antibodies with antigens in the liquid. The beads are trapped around the center of the rotating magnetic field even in the flowing liquid. This newly found phenomenon enables easy bead handling in microreactors. Modification of reactor walls with selected blocking reagents was essential, because protein-coated beads often stick to the wall surface and cannot move freely. Washing steps were also shortened.

  16. A planar conducting micro-loop structure for transportation of magnetic beads: An approach towards rapid sensing and quantification of biological entities

    KAUST Repository

    Gooneratne, Chinthaka Pasan

    2012-03-01

    Magnetic beads are utilized effectively in a wide variety of medical applications due to their small size, biocompatibility and large surface to volume ratio. Microfluidic lab-on-a-chip (LOC) devices, which utilize magnetic beads, are promising tools for accurate and rapid cell sorting and counting. Effective manipulation of beads is a critical factor for the performance of LOC devices. In this paper we propose a planar conducting micro-loop structure to trap, manipulate and transport magnetic beads. Current through the micro-loops produces magnetic field gradients that are proportional to the force required to manipulate the beads. Numerical analyses were performed to study the magnetic forces and their spatial distributions. Experimental results showed that magnetic beads could not only be transported towards a target region, e.g., for sensing purposes, but also the trapping rate could be increased by switching current between the different loops in the micro-loop structure. This method could lead to rapid and accurate quantification of biological entities tagged with magnetic beads. Copyright © 2012 American Scientific Publishers. All rights reserved.

  17. On-chip magnetic bead-based DNA melting curve analysis using a magnetoresistive sensor

    International Nuclear Information System (INIS)

    Rizzi, Giovanni; Østerberg, Frederik W.; Henriksen, Anders D.; Dufva, Martin; Hansen, Mikkel F.

    2015-01-01

    We present real-time measurements of DNA melting curves in a chip-based system that detects the amount of surface-bound magnetic beads using magnetoresistive magnetic field sensors. The sensors detect the difference between the amount of beads bound to the top and bottom sensor branches of the differential sensor geometry. The sensor surfaces are functionalized with wild type (WT) and mutant type (MT) capture probes, differing by a single base insertion (a single nucleotide polymorphism, SNP). Complementary biotinylated targets in suspension couple streptavidin magnetic beads to the sensor surface. The beads are magnetized by the field arising from the bias current passed through the sensors. We demonstrate the first on-chip measurements of the melting of DNA hybrids upon a ramping of the temperature. This overcomes the limitation of using a single washing condition at constant temperature. Moreover, we demonstrate that a single sensor bridge can be used to genotype a SNP. - Highlights: • We apply magnetoresistive sensors to study solid-surface hybridization kinetics of DNA. • We measure DNA melting profiles for perfectly matching DNA duplexes and for a single base mismatch. • We present a procedure to correct for temperature dependencies of the sensor output. • We reliably extract melting temperatures for the DNA hybrids. • We demonstrate direct measurement of differential binding signal for two probes on a single sensor

  18. Fabrication of micromagnetic beads with molecular recognition/electron-transfer peptides for the sensing of ovalbumin

    Energy Technology Data Exchange (ETDEWEB)

    Sugawara, Kazuharu, E-mail: kzsuga@maebashi-it.ac.jp [Maebashi Institute of Technology, Gunma, 371-0816 (Japan); Kuramitz, Hideki [Department of Environmental Biology and Chemistry, Graduate School of Science and Engineering for Research, University of Toyama, Toyama, 930-8555 (Japan); Shinohara, Hiroki [Maebashi Institute of Technology, Gunma, 371-0816 (Japan)

    2017-03-15

    Electrochemical sensing of ovalbumin (OVA) was performed using magnetic beads with OVA recognition (RNRCKGTDVQAW)/electron-transfer (YYYYC) peptides. The focus of this study was to construct a highly sensitive and regenerative tool for OVA detection based on the interaction between a protein and peptide-1(RNRCKGTDVQAWYYYYC). The peptide-1 was introduced to the bead through four types of cross-linking reagents. Magnetic beads of different sizes with N-(6-maleimidocaproyloxy)sulfosuccinimide (Sulfo-EMCS) were also prepared. An oxidation peak due to tyrosine residues at 0.65 V depended on the distance of the electron-transfer peptide from the bead surface and on the surface area of the magnetic beads that contacted the electrode surface. The response of the electro-transfer peptide moiety was decreased because the protein was accumulated via the recognition peptide on the beads. When using Sulfo-EMCS and beads that were 6.0–6.9 μm in diameter, the calibration curve of OVA was linear and ranged from 8.0 × 10{sup −13} to 2.0 × 10{sup −11} M. To regenerate the magnetic beads, the measurements were achieved after removal of the OVA using a denaturing reagent. When OVA was added to fetal bovine serum containing a complex matrix, OVA was recovered at a rate of 98–100%. Consequently, these magnetic beads could be a powerful tool for the sensing of OVA in real samples. - Highlights: • Ovalbumin recognition/electron-transfer peptides were immobilized on magnetic beads. • The accumulation of the protein through the peptides on the beads caused the change of electrode response. • The magnetic beads could be reused for sensing of ovalbumin.

  19. Selective manipulation of superparamagnetic beads by a magnetic microchip

    KAUST Repository

    Gooneratne, Chinthaka Pasan

    2013-07-01

    In this paper, a magnetic microchip (MMC) is presented, to first trap and then selectively manipulate individual, superparamagnetic beads (SPBs) to another trapping site. Trapping sites are realized through soft magnetic micro disks made of Ni80Fe20, and SPB motion is controlled by current-carrying, tapered, conducting lines made of Au. The MMC was realized using standard microfabrication techniques and provides a cheap and versatile platform for microfluidic systems for cell manipulation. © 2013 IEEE.

  20. Planar Hall effect bridge sensors with NiFe/Cu/IrMn stack optimized for self-field magnetic bead detection

    DEFF Research Database (Denmark)

    Henriksen, Anders Dahl; Rizzi, Giovanni; Hansen, Mikkel Fougt

    2016-01-01

    , and 30 nm, and 0 ≤ tCu ≤ 0.6 nm. The sensors were characterized by magnetic hysteresis measurements, by measurements of the sensor response vs. applied field, and by measurements of the sensor response to a suspension of magnetic beads magnetized by the sensor self-field due to the sensor bias current....... The exchange bias field was found to decay exponentially with tCu and inversely with tFM. The reduced exchange field for larger values of tFM and tCu resulted in higher sensitivities to both magnetic fields and magnetic beads. We argue that the maximum magnetic bead signal is limited by Joule heating...

  1. Capture of DNA in microfluidic channel using magnetic beads: increasing capture efficiency with integrated microfluidic mixer

    DEFF Research Database (Denmark)

    Lund-Olesen, Torsten; Dufva, Hans Martin; Hansen, Mikkel Fougt

    2007-01-01

    We have studied the hybridization of target DNA in solution with probe DNA on magnetic beads immobilized on the channel sidewalls in a magnetic bead separator. The hybridization is carried out under a liquid flow and is diffusion limited. Two systems are compared: one with a straight microfluidic...... place on the surface in a microfluidic system....

  2. Detection of a magnetic bead by hybrid nanodevices using scanning gate microscopy

    Science.gov (United States)

    Corte-León, H.; Krzysteczko, P.; Marchi, F.; Motte, J.-F.; Manzin, A.; Schumacher, H. W.; Antonov, V.; Kazakova, O.

    2016-05-01

    Hybrid ferromagnetic(Py)/non-magnetic metal(Au) junctions with a width of 400 nm are studied by magnetotransport measurements, magnetic scanning gate microscopy (SGM) with a magnetic bead (MB) attached to the probe, and micromagnetic simulations. In the transverse geometry, the devices demonstrate a characteristic magnetoresistive behavior that depends on the direction of the in plane magnetic field, with minimum/maximum variation when the field is applied parallel/perpendicular to the Py wire. The SGM is performed with a NdFeB bead of 1.6 μm diameter attached to the scanning probe. Our results demonstrate that the hybrid junction can be used to detect this type of MB. A rough approximation of the sensing volume of the junction has the shape of elliptical cylinder with the volume of ˜1.51 μm3. Micromagnetic simulations coupled to a magnetotransport model including anisotropic magnetoresistance and planar Hall effects are in good agreement with the experimental findings, enabling the interpretation of the SGM images.

  3. A micro-pillar array to trap magnetic beads in microfluidic systems

    KAUST Repository

    Gooneratne, Chinthaka Pasan

    2012-12-01

    A micro-pillar array (MPA) is proposed in this paper to trap and separate magnetic beads (MBs) in microfluidic systems. MBs are used in many biomedical applications due to being compatible in dimension to biomolecules, the large surface area available to attach biomolecules, and the fact that they can be controlled by a magnetic field. Trapping and separating these labeled biomolecules is an important step toward achieving reliable and accurate quantification for disease diagnostics. Nickel Iron (Ni50Fe 50) micro-pillars were fabricated on a Silicon (Si) substrate by standard microfabrication techniques. Experimental results showed that MBs could be trapped on the MPA at the single bead level and separated from other non-target particles. This principle can easily be extended to trap and separate target biomolecules in heterogeneous biological samples. © 2012 IEEE.

  4. Bioinspired methodology for preparing magnetic responsive chitosan beads to be integrated in a tubular bioreactor for biomedical applications.

    Science.gov (United States)

    Song, Wenlong; Oliveira, Mariana B; Sher, Praveen; Gil, Sara; Nóbrega, J Miguel; Mano, João F

    2013-08-01

    Magnetic responsive chitosan beads were prepared using a methodology inspired by the rolling of water droplets over lotus leaves. Liquid precursors containing chitosan and magnetic microparticles were dispensed in the form of spherical droplets and crosslinked with genipin over synthetic superhydrophobic surfaces. Scanning electronic microscopy, histology and micro-computed tomography were employed to characterize the structure of the prepared composite beads and the inner distribution of the magnetic particles. Cellular metabolic activity tests showed that fibroblasts-like (L929 cell line) can adhere and proliferate on the prepared chitosan beads. We hypothesize that such spherical biomaterials could be integrated in a new concept of tubular bioreactor. The magnetic beads can be immobilized by an external magnetic field at specific positions and may be transported along the bioreactor by the drag of the culture medium flow. The system behavior was also studied through numerical modeling, which allowed to identify the relative importance of the main parameters, and to conclude that the distance between carrier beads plays a major role on their interaction with the culture medium and, consequently, on the overall system performance. In an up-scaled version of this bioreactor, the herein presented system may comprise different chambers in serial or parallel configurations. This constitutes a simple way of preparing magnetic responsive beads combined with a new design of bioreactor, which may find application in biomedicine and biotechnology, including in cell expansion for tissue engineering or for the production of therapeutic proteins to be used in cell therapies.

  5. Bioinspired methodology for preparing magnetic responsive chitosan beads to be integrated in a tubular bioreactor for biomedical applications

    International Nuclear Information System (INIS)

    Song, Wenlong; Oliveira, Mariana B; Sher, Praveen; Gil, Sara; Mano, João F; Nóbrega, J Miguel

    2013-01-01

    Magnetic responsive chitosan beads were prepared using a methodology inspired by the rolling of water droplets over lotus leaves. Liquid precursors containing chitosan and magnetic microparticles were dispensed in the form of spherical droplets and crosslinked with genipin over synthetic superhydrophobic surfaces. Scanning electronic microscopy, histology and micro-computed tomography were employed to characterize the structure of the prepared composite beads and the inner distribution of the magnetic particles. Cellular metabolic activity tests showed that fibroblasts-like (L929 cell line) can adhere and proliferate on the prepared chitosan beads. We hypothesize that such spherical biomaterials could be integrated in a new concept of tubular bioreactor. The magnetic beads can be immobilized by an external magnetic field at specific positions and may be transported along the bioreactor by the drag of the culture medium flow. The system behavior was also studied through numerical modeling, which allowed to identify the relative importance of the main parameters, and to conclude that the distance between carrier beads plays a major role on their interaction with the culture medium and, consequently, on the overall system performance. In an up-scaled version of this bioreactor, the herein presented system may comprise different chambers in serial or parallel configurations. This constitutes a simple way of preparing magnetic responsive beads combined with a new design of bioreactor, which may find application in biomedicine and biotechnology, including in cell expansion for tissue engineering or for the production of therapeutic proteins to be used in cell therapies. (paper)

  6. Microfluidic magnetic separator using an array of soft magnetic elements

    DEFF Research Database (Denmark)

    Smistrup, Kristian; Lund-Olesen, Torsten; Hansen, Mikkel Fougt

    2006-01-01

    We present the design, fabrication, characterization, and demonstration of a new passive magnetic bead separator. The device operates in an effective state when magnetized by an external magnetic field of only 50 mT, which is available from a tabletop electromagnet. We demonstrate the complete...... capture of 1.0 mu m fluorescent magnetic beads from a 7.5 mu L sample volume traveling at an average linear fluid velocity of 5 mm/s....

  7. One pot synthesis of new poly(vinyl alcohol) blended natural polymer based magnetic hydrogel beads: Controlled natural anticancer alkaloid delivery system.

    Science.gov (United States)

    Kesavan, Mookkandi Palsamy; Ayyanaar, Srinivasan; Lenin, Nayagam; Sankarganesh, Murugesan; Dhaveethu Raja, Jeyaraj; Rajesh, Jegathalaprathaban

    2018-02-01

    Facile one-pot synthesis has been demonstrated for new biocompatible and dual responsive magnetic iron oxide nanoparticles cross-linked poly(vinyl alcohol) (PVA) blended natural polymer chitosan (CS) based hydrogel beads (mCS-PVA) as a controlled natural anticancer alkaloid Luotonin A (LuA) delivery system. The prepared magnetic hydrogel beads were characterized using powder X-ray diffraction measurement, Fourier transform-infrared spectroscopy, scanning electron microscopy, energy dispersive X-ray spectroscopy, and vibrating sample magnetometer. The magnetic hydrogel beads are exhibited significant water retention and follow the second order kinetic model in swelling study. The swelling ratio of the magnetic gel beads increased by the addition of PVA and showed a maximum swelling ratio of 40.83 ± 1.01 g/g and follows non-Fickian water transport mechanism. Stimuli responsive mCS and mCS-PVA hydrogel beads functionalized with LuA is demonstrated for controlled release at physiological pH and under magnetic field. The magnetic hydrogel beads show highest LuA releasing efficacy at acidic medium (pH = 5.0) with maximum efficiency of 73.33 ± 1.44%. This efficacy may also be tuned by altering the external magnetic field as well as the weight percentage (wt %) of polyethylene glycol. It is clearly that the newly produced magnetic hydrogel beads can be served as an effective intestinal LuA delivery system. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A: 543-551, 2018. © 2017 Wiley Periodicals, Inc.

  8. Concanavalin A immobilized magnetic poly(glycidyl methacrylate) beads for prostate specific antigen binding.

    Science.gov (United States)

    Idil, Neslihan; Perçin, Işık; Karakoç, Veyis; Yavuz, Handan; Aksöz, Nilüfer; Denizli, Adil

    2015-10-01

    The aim of this study was to prepare Concanavalin A (Con A) immobilized magnetic poly(glycidyl methacrylate) (mPGMA) beads for prostate specific antigen (PSA) binding and to study binding capacities of the beads using lectin-glycoprotein interactions. Firstly, iron oxide nanoparticles were synthesized by co-precipitation method and then, beads were synthesized by dispersion polymerization in the presence of iron oxide nanoparticles. Con A molecules were both covalently immobilized onto the beads directly and through the spacer arm (1,6-diaminohexane-HDMA). The total PSA and free PSA binding onto the mPGMA-HDMA-Con A beads were higher than that of the mPGMA-Con A beads. Maximum PSA binding capacity was observed as 91.2 ng/g. Approximately 45% of the bound PSA was eluted by using 0.1 M mannose as elution agent. The mPGMA-HDMA-Con A beads could be reused without a remarkable decrease in the binding capacities after 5 binding-desorption cycles. Serum fractions were analyzed using SDS-PAGE. The mPGMA-HDMA-Con A beads could be useful for the detection of PSA and suggested as a model system for other glycoprotein biomarkers. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Magnetic iron oxide nanoparticles (MIONs) cross-linked natural polymer-based hybrid gel beads: Controlled nano anti-TB drug delivery application.

    Science.gov (United States)

    Kesavan, Mookkandi Palsamy; Ayyanaar, Srinivasan; Vijayakumar, Vijayaparthasarathi; Dhaveethu Raja, Jeyaraj; Annaraj, Jamespandi; Sakthipandi, Kathiresan; Rajesh, Jegathalaprathaban

    2018-04-01

    The nanosized rifampicin (RIF) has been prepared to increase the solubility in aqueous solution, which leads to remarkable enhancement of its bioavailability and their convenient delivery system studied by newly produced nontoxic, biodegradable magnetic iron oxide nanoparticles (MIONs) cross-linked polyethylene glycol hybrid chitosan (mCS-PEG) gel beads. The functionalization of both nano RIF and mCS-PEG gel beads were studied using various spectroscopic and microscopic techniques. The size of prepared nano RIF was found to be 70.20 ± 3.50 nm. The mechanical stability and swelling ratio of the magnetic gel beads increased by the addition of PEG with a maximum swelling ratio of 38.67 ± 0.29 g/g. Interestingly, this magnetic gel bead has dual responsive assets in the nano drug delivery application (pH and the magnetic field). As we expected, magnetic gel beads show higher nano drug releasing efficacy at acidic medium (pH = 5.0) with maximum efficiency of 71.00 ± 0.87%. This efficacy may also be tuned by altering the external magnetic field and the weight percentage (wt%) of PEG. These results suggest that such a dual responsive magnetic gel beads can be used as a potential system in the nano drug delivery applications. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A: 1039-1050, 2018. © 2017 Wiley Periodicals, Inc.

  10. A micro-pillar array to trap magnetic beads in microfluidic systems

    KAUST Repository

    Gooneratne, Chinthaka Pasan; Kosel, Jü rgen

    2012-01-01

    A micro-pillar array (MPA) is proposed in this paper to trap and separate magnetic beads (MBs) in microfluidic systems. MBs are used in many biomedical applications due to being compatible in dimension to biomolecules, the large surface area

  11. Bead magnetorelaxometry with an on-chip magnetoresistive sensor

    DEFF Research Database (Denmark)

    Dalslet, Bjarke Thomas; Damsgaard, Christian Danvad; Donolato, Marco

    2011-01-01

    Magnetorelaxometry measurements on suspensions of magnetic beads are demonstrated using a planar Hall effect sensor chip embedded in a microfluidic system. The alternating magnetic field used for magnetizing the beads is provided by the sensor bias current and the complex magnetic susceptibility...... spectra are recorded as the 2nd harmonic of the sensor response. The complex magnetic susceptibility signal appears when a magnetic bead suspension is injected, it scales with the bead concentration, and it follows the Cole-Cole expression for Brownian relaxation. The complex magnetic susceptibility...... signal resembles that from conventional magnetorelaxometry done on the same samples apart from an offset in Brownian relaxation frequency. The time dependence of the signal can be rationalized as originating from sedimented beads....

  12. Detection of a magnetic bead by hybrid nanodevices using scanning gate microscopy

    Directory of Open Access Journals (Sweden)

    H. Corte-León

    2016-05-01

    Full Text Available Hybrid ferromagnetic(Py/non-magnetic metal(Au junctions with a width of 400 nm are studied by magnetotransport measurements, magnetic scanning gate microscopy (SGM with a magnetic bead (MB attached to the probe, and micromagnetic simulations. In the transverse geometry, the devices demonstrate a characteristic magnetoresistive behavior that depends on the direction of the in plane magnetic field, with minimum/maximum variation when the field is applied parallel/perpendicular to the Py wire. The SGM is performed with a NdFeB bead of 1.6 μm diameter attached to the scanning probe. Our results demonstrate that the hybrid junction can be used to detect this type of MB. A rough approximation of the sensing volume of the junction has the shape of elliptical cylinder with the volume of ∼1.51 μm3. Micromagnetic simulations coupled to a magnetotransport model including anisotropic magnetoresistance and planar Hall effects are in good agreement with the experimental findings, enabling the interpretation of the SGM images.

  13. Polyaniline coated magnetic carboxymethylcellulose beads for selective removal of uranium ions from aqueous solution

    International Nuclear Information System (INIS)

    Yakup Arica, M.; Gulay Bayramoglu; Gazi University, Ankara

    2016-01-01

    Magnetic carboxymethylcellulose (CMC) beads were prepared via ionic cross-linking. Then CMC beads were coated with polyaniline (PANI). The results of FTIR, SEM, DTA and N 2 adsorption-desorption demonstrated that aniline was successfully grafted onto the surface of mCMC beads. The potential use of the prepared adsorbent was used for removal of U(VI) ions. The determined maximum adsorption capacities of the mCMC and mCMC-g-PANI beads for U(VI) ions were 129.4 and 386.5 mg/g dry weight at pH 4.5, respectively. The thermodynamic parameters (ΔH°, ΔS° and ΔG°) were evaluated. The adsorbent systems were regenerated using 0.1 M HCl. (author)

  14. Construction of microscale structures in enclosed microfluidic networks by using a magnetic beads based method.

    Science.gov (United States)

    Wang, Zhenyu; Zhang, Xiaojuan; Yang, Jun; Yang, Zhong; Wan, Xiaoping; Hu, Ning; Zheng, Xiaolin

    2013-08-20

    A large number of microscale structures have been used to elaborate flowing control or complex biological and chemical reaction on microfluidic chips. However, it is still inconvenient to fabricate microstructures with different heights (or depths) on the same substrate. These kinds of microstructures can be fabricated by using the photolithography and wet-etching method step by step, but involves time-consuming design and fabrication process, as well as complicated alignment of different masters. In addition, few existing methods can be used to perform fabrication within enclosed microfluidic networks. It is also difficult to change or remove existing microstructures within these networks. In this study, a magnetic-beads-based approach is presented to build microstructures in enclosed microfluidic networks. Electromagnetic field generated by microfabricated conducting wires (coils) is used to manipulate and trap magnetic beads on the bottom surface of a microchannel. These trapped beads are accumulated to form a microscale pile with desired shape, which can adjust liquid flow, dock cells, modify surface, and do some other things as those fabricated microstructures. Once the electromagnetic field is changed, trapped beads may form new shapes or be removed by a liquid flow. Besides being used in microfabrication, this magnetic-beads-based method can be used for novel microfluidic manipulation. It has been validated by forming microscale dam structure for cell docking and modified surface for cell patterning, as well as guiding the growth of neurons. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. A multi-purpose ultrasonic streaming mixer for integrated magnetic bead ELISAs

    International Nuclear Information System (INIS)

    Brandhoff, Lukas; Lang, Walter; Vellekoop, Michael J; Zirath, Helene; Peham, Johannes; Wiesinger-Mayr, Herbert; Salas, Mariugenia; Haller, Anna; Spittler, Andreas; Schnetz, Guntram

    2015-01-01

    We present an ultrasonic streaming mixer for disposable and on-chip magnetic bead ELISAs. The ultrasonic transducer is placed at system-level to keep cost per chip as low as possible, and is coupled to the chip by means of a solid ultrasonic horn. The system provides mixing of liquids, as well as dispersion of the superparamagnetic beads in the ELISA. Additionally it can be used clean the chamber surface from nonspecifically bound proteins during the washing steps in the ELISA protocol. Using our system the time for the ELISA protocol has been greatly reduced down to 30 min. (paper)

  16. Using Magnets and Magnetic Beads to Dissect Signaling Pathways Activated by Mechanical Tension Applied to Cells

    Science.gov (United States)

    Marjoram, R.J.; Guilluy, C; Burridge, K.

    2015-01-01

    Cellular tension has implications in normal biology and pathology. Membrane adhesion receptors serve as conduits for mechanotransduction that lead to cellular responses. Ligand-conjugated magnetic beads are a useful tool in the study of how cells sense and respond to tension. Here we detail methods for their use in applying tension to cells and strategies for analyzing the results. We demonstrate the methods by analyzing mechanotransduction through VE-cadherin on endothelial cells using both permanent magnets and magnetic tweezers. PMID:26427549

  17. Kinase-loaded magnetic beads for sequential in vitro phosphorylation of peptides and proteins.

    Science.gov (United States)

    Hromadkova, Lenka; Kupcik, Rudolf; Vajrychova, Marie; Prikryl, Petr; Charvatova, Andrea; Jankovicova, Barbora; Ripova, Daniela; Bilkova, Zuzana; Slovakova, Marcela

    2018-01-15

    Post-translational modifications, including phosphorylation, greatly impact the physiological function of proteins, especially those that are natively unfolded and implicated in many neurodegenerative diseases. However, structural and functional studies of such proteins require fully defined phosphorylation, including those that are not physiological. Thus, the kinases ERK2 and GSK-3β were immobilized to various superparamagnetic beads with carboxylic, aldehyde, Ni 2+ , or Co 3+ functional groups, with a view to efficiently phosphorylate peptides and proteins in vitro. Full phosphorylation of specific synthetic peptides confirmed that beads were successfully loaded with kinases. Remarkably, enzymes covalently immobilized on carboxylated SeraMag beads remained active upon reuse, with residual activity after 10 uses 99.5 ± 0.34% for GSK-3β and 36.2 ± 2.01% for ERK2. The beads were also used to sequentially phosphorylate recombinant tau, which in vivo is a biomarker of Alzheimer's disease. Thus, a system consisting of two fully active kinases immobilized to magnetic beads is demonstrated for the first time. In comparison to soluble enzymes, the beads are easier to handle, reusable, and thus low-cost. Importantly, these beads are also convenient to remove from reactions to minimize contamination of phosphorylated products or to exchange with other kinases.

  18. Synthesis of magnetic hollow silica using polystyrene bead as a template

    International Nuclear Information System (INIS)

    Wu, W.; Caruntu, D.; Martin, A.; Yu, M.H.; O'Connor, C.J.; Zhou, W.L.; Chen, J.-F.

    2007-01-01

    In this paper, we report a new route to synthesize novel magnetic hollow silica nanospheres (MHSNs) using polystyrene particles as sacrificial templates, and TEOS and Fe 3 O 4 as precursors. TEM, EDS, XRD, and SQUID were applied to characterize MHSNs. TEM and EDS results show that the MHSNs consist of about 200 nm of hollow cores and ∼35 nm shells with ∼10 nm of Fe 3 O 4 nanoparticles embedded. The polystyrene beads were successfully removed by immersing the as-prepared silica nanocomposite in a toluene solution. XRD results demonstrate that the Fe 3 O 4 magnetic nanoparticles still keep spinel structure even heated at low temperature. The surface status of the polystyrene beads and Fe 3 O 4 nanoparticles has an important effect on the formation of the MHSNs. The MHSNs present a superparamagnetism at room temperature by SQUID measurement. The MHSNs have potential applications in biosystem and nanomedicine

  19. High heat generation ability in AC magnetic field for nano-sized magnetic Y3Fe5O12 powder prepared by bead milling

    International Nuclear Information System (INIS)

    Aono, Hiromichi; Ebara, Hiroki; Senba, Ryota; Naohara, Takashi; Maehara, Tsunehiro; Hirazawa, Hideyuki; Watanabe, Yuji

    2012-01-01

    Nano-sized magnetic Y 3 Fe 5 O 12 ferrite having a high heat generation ability in an AC magnetic field was prepared by bead milling. A commercial powder sample (non-milled sample) of ca. 2.9 μm in particle size did not show any temperature enhancement in the AC magnetic field. The heat generation ability in the AC magnetic field improved with a decrease in the average crystallite size for the bead-milled Y 3 Fe 5 O 12 ferrites. The highest heat ability in the AC magnetic field was for the fine Y 3 Fe 5 O 12 powder with a 15-nm crystallite size (the samples were milled for 4 h using 0.1 mmφ beads). The heat generation ability of the excessively milled Y 3 Fe 5 O 12 samples decreased. The main reason for the high heat generation property of the milled samples was ascribed to an increase in the Néel relaxation of the superparamagnetic material. The heat generation ability was not influenced by the concentration of the ferrite powder. For the samples milled for 4 h using 0.1 mmφ beads, the heat generation ability (W g −1 ) was estimated using a 3.58×10 −4 fH 2 frequency (f/kHz) and the magnetic field (H/kA m −1 ), which is the highest reported value of superparamagnetic materials. - Highlights: ► The nano-sized Y 3 Fe 5 O 12 powder prepared by bead-milling has the highest heat generation ability in an AC magnetic field. ► The heat generation properties are ascribed to an increase in the Néel relaxation of the superparamagnetic material. ► The heat ability (W g −1 ) can be estimated using 3.58×10 −4 fH 2 (f=kHz, H=kA m −1 ). ► This is an expectable material for use in a drug delivery system for the thermal coagulation therapy of cancer tumors.

  20. Investigation on rare earth magnets recycling by organophosphoric extractant encapsulated polymeric beads for separation of dysprosium

    International Nuclear Information System (INIS)

    Yadav, Kartikey K.; Singh, D.K.; Kain, V.

    2017-01-01

    Rare earth elements (REEs) are a basic requirement of the electronics and new industries including green technology. In the present work an organophosphoric extractant encapsulating polyethersulfone (PES) beads has been developed and employed for dysprosium (Dy) separation from aqueous stream. Polyethersulfonic beads encapsulating PC88A were prepared by phase inversion method. During the synthesis of the beads, preparatory parameters were also optimized to obtain best suited beads which were subsequently characterized for their encapsulation capacity and micro structural investigation. The results obtained in the present investigation suggested that PES/PVAJPC88A composite beads could be used for separation of rare earths from aqueous medium obtained from the solubilisation of magnetic scrap materials

  1. Magnetic bead/capture DNA/glucose-loaded nanoliposomes for amplifying the glucometer signal in the rapid screening of hepatitis C virus RNA.

    Science.gov (United States)

    Tu, Haijian; Lin, Kun; Lun, Yongzhi; Yu, Liuming

    2018-06-01

    A digital detection strategy based on a portable personal glucometer (PGM) was developed for the simple, rapid, and sensitive detection of hepatitis C virus (HCV) RNA, involving the release of glucose-loaded nanoliposomes due to coupling-site-specific cleavage by the endonuclease BamHI. The glucose-loaded nanoliposomes were synthesized using a reversed-phase evaporation method and provided an amplified signal at the PGM in the presence of HCV RNA. Initially, a 21-mer oligonucleotide complementary to HCV RNA was covalently conjugated to a magnetic bead through the amino group at the 5' end of the oligonucleotide, and then bound to a glucose-loaded liposome by typical carbodiimide coupling at its 3' end. In the presence of the target HCV RNA, the target hybridized with the oligonucleotide to form double-stranded DNA. The symmetrical duplex sequence 5'-GGATCC-3' between guanines was then catalytically cleaved by BamHI, which detached the glucose-loaded liposome from the magnetic bead. Following magnetic separation of the bead, the detached glucose-loaded liposome was lysed using Triton X-100 to release the glucose molecules within it, which were then detected as an amplified signal at the digital PGM. Under optimal conditions, the PGM signal increased with increasing HCV RNA, and displayed a strongly linear dependence on the level of HCV RNA for concentrations ranging from 10 pM to 1.0 μM. The detection limit (LOD) of the system was 1.9 pM. Good reproducibility and favorable specificity were achieved in the analysis of the target HCV RNA. Human serum samples containing HCV RNA were analyzed using this strategy, and the developed sensing platform was observed to yield satisfactory results based on a comparison with the corresponding results from a Cobas ® Amplicor HCV Test Analyzer. Graphical abstract A digital detection strategy utilizing a personal glucometer was developed for the detection of hepatitis C virus RNA. The strategy involved the use of the

  2. Observation of the dynamics of magnetically induced chains of sub-micron superparamagnetic beads in aqueous solutions by laser light scattering

    International Nuclear Information System (INIS)

    Tanizawa, Y; Tashiro, T; Sandhu, A; Ko, P J

    2013-01-01

    Optical monitoring the behaviour of magnetically induced self-assembled chains of superparamagnetic beads (SPBs) are of interest for biomedical applications such as biosensors. However, it is difficult to directly monitor magnetically induced self-assembly of sub-micron nano-beads with conventional optical microscopes. Here, we describe the optical observation of the dynamics of magnetically induced self-assembled rotating chains of 130 nm SPBs in aqueous solutions by laser light scattering. Magnetic fields of ∼1 kOe were applied to control the self-assembly chains of SPBs and their behaviour analyzed by monitoring the intensity of laser light scattered from the chain structures. We compared the light scattering from chains that were formed only by the application of external fields with chains formed by beads functionalized by EDC, where chemical reactions lead to the bonding of individual beads to form chains. The EDC experiments are a precursor to experiments on molecular recognition applications for biomedical diagnostics.

  3. Magnetic bead manipulation in a sub-microliter fluid volume applicable for biosensing

    NARCIS (Netherlands)

    Derks, R.J.S.; Wimberger-Friedl, R.; Prins, M.W.J.; Dietzel, A.H.

    2007-01-01

    Magnetic actuation principles using superparamagnetic beads suspended in a fluid are studied in this paper. An exptl. setup contg. a submicroliter fluid vol. surrounded by four miniaturized electromagnets was designed and fabricated. On the basis of optical velocity measurements, the induced

  4. Magnetic polymer beads: Recent trends and developments in synthetic design and applications

    KAUST Repository

    Philippova, Olga

    2011-04-01

    The paper describes the synthesis, properties and applications of magnetic polymer beads. State-of-the-art, future challenges, and promising trends in this field are analyzed. New applications in oil recovery are described. © 2010 Elsevier Ltd. All rights reserved.

  5. Magnetic polymer beads: Recent trends and developments in synthetic design and applications

    KAUST Repository

    Philippova, Olga; Barabanova, Anna; Molchanov, Vyacheslav; Khokhlov, Alexei

    2011-01-01

    The paper describes the synthesis, properties and applications of magnetic polymer beads. State-of-the-art, future challenges, and promising trends in this field are analyzed. New applications in oil recovery are described. © 2010 Elsevier Ltd. All rights reserved.

  6. Iron Nanoparticles (Fe3O4 Used to Synthesize Magnetic Sodium Alginate Hydrogel Beads for the Removal of Basic Blue 159 from Aqueous Solutions

    Directory of Open Access Journals (Sweden)

    Atiyeh Ghajarieh

    2017-11-01

    Full Text Available Dyes are a main source of pollutants in textile plant effluents. Due to their molecular structure, they are usually toxic, carcinogenous, and persistent in the environment. The aim of the present work was to explore the removal of basic blue159 (BB159 using magnetic sodium alginate hydrogel beads. Magnetic sodium alginate hydrogel beads were initially synthesized  accoriodng to Rocher method using CaCl2 as a crosslink agent. Fourier transform infrared spectroscopy (FTIR was then employed to examine the functional groups on the surface of the magnetic sodium alginate hydrogel beads. In a third stage, the magnetic properties of the beads were measured using a vibrating sample magnetometer (VSM and the magnetic parameters were calculated. Subsequently, the effects of such parameters as adsorbent dosage, pH, initial concentration of dye, and contact time were evaluated on the BB159 removal efficiency of the adsorbent used. Finally, the Langmuir, Freundlich, Temkin, and B.E.T models were exploited to study the adsorption isotherm of BB159 onto the magnetic sodium alginate hydrogel beads. It was found that the magnetic sodium alginate beads possess both –COO and –OH groups that play important roles in the adsorption of the positively charged BB159 dye. A saturation magnetization equal to 21/8(emu/g was obtained for the sodium alginate beads/nano Fe3O4. Results also revealed that the highest dye removal from aqueous solutions was achieved at pH=11 in 120 minutes for 9 grams of the adsorbent. The study indicated that BB159 removal using the magnetic sodium alginate hydrogel beads as the adsorbent obeys the Langmuir model. Moreover, it was shown that the efficiency of the process for BB159 removal from aqueous solutions was satisfactory (85%.

  7. Comparison of La3+ and mixed rare earths-loaded magnetic chitosan beads for fluoride adsorption

    DEFF Research Database (Denmark)

    Liang, Peng; An, Ruiqi; Li, Ruifen

    2018-01-01

    La3+ and mixed-rare earth magnetic chitosan beads (MCLB and MCLRB) were successfully prepared for fluoride removal, respectively. The adsorbents were characterized by scanning electron microscope and magnetic response. Batch experiments were carried out to investigate the adsorbent performance...

  8. A magnetic bead-based ligand binding assay to facilitate human kynurenine 3-monooxygenase drug discovery.

    Science.gov (United States)

    Wilson, Kris; Mole, Damian J; Homer, Natalie Z M; Iredale, John P; Auer, Manfred; Webster, Scott P

    2015-02-01

    Human kynurenine 3-monooxygenase (KMO) is emerging as an important drug target enzyme in a number of inflammatory and neurodegenerative disease states. Recombinant protein production of KMO, and therefore discovery of KMO ligands, is challenging due to a large membrane targeting domain at the C-terminus of the enzyme that causes stability, solubility, and purification difficulties. The purpose of our investigation was to develop a suitable screening method for targeting human KMO and other similarly challenging drug targets. Here, we report the development of a magnetic bead-based binding assay using mass spectrometry detection for human KMO protein. The assay incorporates isolation of FLAG-tagged KMO enzyme on protein A magnetic beads. The protein-bound beads are incubated with potential binding compounds before specific cleavage of the protein-compound complexes from the beads. Mass spectrometry analysis is used to identify the compounds that demonstrate specific binding affinity for the target protein. The technique was validated using known inhibitors of KMO. This assay is a robust alternative to traditional ligand-binding assays for challenging protein targets, and it overcomes specific difficulties associated with isolating human KMO. © 2014 Society for Laboratory Automation and Screening.

  9. Heterogeneous time-resolved electrochemiluminoimmunoassay of thyroid stimulating hormone with magnetic beads at oxide-covered aluminum electrode

    Energy Technology Data Exchange (ETDEWEB)

    Ala-Kleme, Timo, E-mail: timo.ala-kleme@utu.fi

    2017-06-15

    The heterogeneous immunoassay of thyroid stimulating hormone (TSH) was detected by the time-resolved cathodic electrochemiluminescence immunoassay (tr-CECLIA) method using magnetic beads as a mobile support. The magnetic beads coated with sandwich type TSH immunoassay were captured with a magnet for washing and detection processes. The time-resolved cathodic electrochemiluminescence (tr-CECL) signal of Tb(III) chelate label was generated by cathodic pulse polarization in the aluminum working electrode and platinum counter electrode system. The detection method causes injection of high energy electrons into the aqueous solution near the aluminum electrode and creates rigid simultaneous oxidative and reductive conditions that excitate the Tb(III) chelate used as a label luminophore in the heterogeneous sandwich type immunoassay of TSH in the surface of the magnetic beads. The limit of detection of the method was about 50 mIU L{sup −1}. The precision of it was noticed to be good; the coefficient variation percentage was realized to be lower than 10 %. Unfortunately the limit of detection is not good enough for determination of analyte levels of very low concentrations for instance TSH in body fluids. The possible application areas of the method are in highly sophisticated micro or nano fluidic detection and sensor systems where the aspiration level of the analyte detection limit is not very high and the mobility and manageability and the large surface area of the magnetic beads can be utilized efficiently in separating, washing, moving, coating and detecting processes. In the case of tr-CECLIA the presented method makes possible to use multipurpose working electrodes instead of disposable ones.

  10. Hydrodynamic Torques and Rotations of Superparamagnetic Bead Dimers

    Science.gov (United States)

    Pease, Christopher; Etheridge, J.; Wijesinghe, H. S.; Pierce, C. J.; Prikockis, M. V.; Sooryakumar, R.

    Chains of micro-magnetic particles are often rotated with external magnetic fields for many lab-on-a-chip technologies such as transporting beads or mixing fluids. These applications benefit from faster responses of the actuated particles. In a rotating magnetic field, the magnetization of superparamagnetic beads, created from embedded magnetic nano-particles within a polymer matrix, is largely characterized by induced dipoles mip along the direction of the field. In addition there is often a weak dipole mop that orients out-of-phase with the external rotating field. On a two-bead dimer, the simplest chain of beads, mop contributes a torque Γm in addition to the torque from mip. For dimers with beads unbound to each other, mop rotates individual beads which generate an additional hydrodynamic torque on the dimer. Whereas, mop directly torques bound dimers. Our results show that Γm significantly alters the average frequency-dependent dimer rotation rate for both bound and unbound monomers and, when mop exceeds a critical value, increases the maximum dimer rotation frequency. Models that include magnetic and hydrodynamics torques provide good agreement with the experimental findings over a range of field frequencies.

  11. [Evaluation of TB-beads assay utilizing the technique of magnetic beads--an innovative assay method for detection of acid fast bacilli].

    Science.gov (United States)

    Ohkuma, Masanori; Ikeda, Katsuyoshi; Obayashi, Konen; Ando, Yukio; Koriyama, Toyoyasu; Kimu, Minhi; Hirose, Nobuyuki; Nagasawa, Zenzo; Miyamoto, Hiroshi

    2012-01-01

    The centrifuge method with the use of Semi-Alkalin Proteinase (SAP) and NALC-NaOH, recommended by the "2007 edition of the assay guideline for detection of Mycobacterium tuberculosis," has significantly contributed to improving the sensitivities and specificities of both smear and culture tests for detection of acid fast bacilli (AFB). However, this method poses some challenges in terms of its cumbersome and time-consuming assay protocol. "TB-beads (Kyokuto Pharmaceutical Industrial Co., Ltd.)" is a newly-developed method for detection of AFB utilizing magnetic beads. We evaluated the quality of this method in comparison with the centrifuge method, focusing on the results of smear and culture tests. This evaluation study was conducted using both 5 positive and 5 negative sputum samples. The sensitivity of TB-beads for fluorescent smear tests, conducted using "Acri-stain," was almost the same as that of the centrifuge method. One advantage of TB-beads, however, was that it was very convenient to practice microscopic observation due to the clear background of the smeared glass slides. The comparison of the contamination rates between the two methods showed that TB-beads suggested significantly lower contamination rates. The centrifuge method resulted in 50% and 60% of contamination rates for HK Semisolid Isolation Medium and BacT/ALERT MP, respectively. On the other hand, the contamination rates of TB-beads for both of the culture methods were only 10%. With regard to the 5 positive sputum samples, the comparison of the detection rates between the centrifuge and TB-Beads method was made utilizing Myco Acid, Ogawa K, and BacT/ALERT MP. The TB-Beads method suggested higher detection rates for Myco Acid and Ogawa K, while there were no significant differences between the two methods for BacT/ALERT MP (16-23 days). TB-beads is an easy method that allows to simplify the process of smear tests, and contributes to significantly reducing the contamination rate of culture

  12. Superparamagnetic poly(methyl methacrylate) beads for nattokinase purification from fermentation broth.

    Science.gov (United States)

    Yang, Chengli; Xing, Jianmin; Guan, Yueping; Liu, Huizhou

    2006-09-01

    An effective method for purification of nattokinase from fermentation broth using magnetic poly(methyl methacrylate) (PMMA) beads immobilized with p-aminobenzamidine was proposed in this study. Firstly, magnetic PMMA beads with a narrow size distribution were prepared by spraying suspension polymerization. Then, they were highly functionalized via transesterification reaction with polyethylene glycol. The surface hydroxyl-modified magnetic beads obtained were further modified with chloroethylamine to transfer the surface amino-modified magnetic functional beads. The morphology and surface functionality of the magnetic beads were examined by scanning electron microscopy and Fourier transform infrared. An affinity ligand, p-aminobenzamidine was covalently immobilized to the amino-modified magnetic beads by the glutaraldehyde method for nattokinase purification directly from the fermentation broth. The purification factor and the recovery of the enzyme activity were found to be 8.7 and 85%, respectively. The purification of nattokinase from fermentation broth by magnetic beads only took 40 min, which shows a very fast purification of nattokinase compared to traditional purification methods.

  13. Development of a magnetic bead-based method for the collection of circulating extracellular vesicles.

    Science.gov (United States)

    Shih, Chun-Liang; Chong, Kowit-Yu; Hsu, Shih-Che; Chien, Hsin-Jung; Ma, Ching-Ting; Chang, John Wen-Cheng; Yu, Chia-Jung; Chiou, Chiuan-Chian

    2016-01-25

    Cells release different types of extracellular vesicles (EVs). These EVs contain biomolecules, including proteins and nucleic acids, from their parent cells, which can be useful for diagnostic applications. The aim of this study was to develop a convenient procedure to collect circulating EVs with detectable mRNA or other biomolecules. Magnetic beads coated with annexin A5 (ANX-beads), which bound to phosphatidylserine moieties on the surfaces of most EVs, were tested for their ability to capture induced apoptotic bodies in vitro and other phosphatidylserine-presenting vesicles in body fluids. Our results show that up to 60% of induced apoptotic bodies could be captured by the ANX-beads. The vesicles captured from cultured media or plasma contained amplifiable RNA. Suitable blood samples for EV collection included EDTA-plasma and serum but not heparin-plasma. In addition, EVs in plasma were labile to freeze-and-thaw cycles. In rodents xenografted with human cancer cells, tumor-derived mRNA could be detected in EVs captured from serum samples. Active proteins could be detected in EVs captured from ascites but not from plasma. In conclusion, we have developed a magnetic bead-based procedure for the collection of EVs from body fluids and proved that captured EVs contain biomolecules from their parent cells, and therefore have great potential for disease diagnosis. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Optimization of magnetoresistive sensor current for on-chip magnetic bead detection using the sensor self-field

    DEFF Research Database (Denmark)

    Henriksen, Anders Dahl; Rizzi, Giovanni; Østerberg, Frederik Westergaard

    2015-01-01

    We investigate the self-heating of magnetoresistive sensors used for measurements on magnetic beads in magnetic biosensors. The signal from magnetic beads magnetized by the field due to the sensor bias current is proportional to the bias current squared. Therefore, we aim to maximize the bias...... current while limiting the sensor self-heating. We systematically characterize and model the Joule heating of magnetoresistive sensors with different sensor geometries and stack compositions. The sensor heating is determined using the increase of the sensor resistance as function of the bias current......, thus the heat conductance is proportional to the sensor area and inversely proportional to the oxide thickness. This simple heat conductance determines the relationship between bias current and sensor temperature, and we show that View the MathML source25μm wide sensor on a View the MathML source1μm...

  15. A magnetic bead-based method for concentrating DNA from human urine for downstream detection.

    Science.gov (United States)

    Bordelon, Hali; Russ, Patricia K; Wright, David W; Haselton, Frederick R

    2013-01-01

    Due to the presence of PCR inhibitors, PCR cannot be used directly on most clinical samples, including human urine, without pre-treatment. A magnetic bead-based strategy is one potential method to collect biomarkers from urine samples and separate the biomarkers from PCR inhibitors. In this report, a 1 mL urine sample was mixed within the bulb of a transfer pipette containing lyophilized nucleic acid-silica adsorption buffer and silica-coated magnetic beads. After mixing, the sample was transferred from the pipette bulb to a small diameter tube, and captured biomarkers were concentrated using magnetic entrainment of beads through pre-arrayed wash solutions separated by small air gaps. Feasibility was tested using synthetic segments of the 140 bp tuberculosis IS6110 DNA sequence spiked into pooled human urine samples. DNA recovery was evaluated by qPCR. Despite the presence of spiked DNA, no DNA was detectable in unextracted urine samples, presumably due to the presence of PCR inhibitors. However, following extraction with the magnetic bead-based method, we found that ∼50% of spiked TB DNA was recovered from human urine containing roughly 5×10(3) to 5×10(8) copies of IS6110 DNA. In addition, the DNA was concentrated approximately ten-fold into water. The final concentration of DNA in the eluate was 5×10(6), 14×10(6), and 8×10(6) copies/µL for 1, 3, and 5 mL urine samples, respectively. Lyophilized and freshly prepared reagents within the transfer pipette produced similar results, suggesting that long-term storage without refrigeration is possible. DNA recovery increased with the length of the spiked DNA segments from 10±0.9% for a 75 bp DNA sequence to 42±4% for a 100 bp segment and 58±9% for a 140 bp segment. The estimated LOD was 77 copies of DNA/µL of urine. The strategy presented here provides a simple means to achieve high nucleic acid recovery from easily obtained urine samples, which does not contain inhibitors of PCR.

  16. Fibrous polymer grafted magnetic chitosan beads with strong poly(cation-exchange) groups for single step purification of lysozyme.

    Science.gov (United States)

    Bayramoglu, Gulay; Tekinay, Turgay; Ozalp, V Cengiz; Arica, M Yakup

    2015-05-15

    Lysozyme is an important polypetide used in medical and food applications. We report a novel magnetic strong cation exchange beads for efficient purification of lysozyme from chicken egg white. Magnetic chitosan (MCHT) beads were synthesized via phase inversion method, and then grafted with poly(glycidyl methacrylate) (p(GMA)) via the surface-initiated atom transfer radical polymerization (SI-ATRP). Epoxy groups of the grafted polymer, were modified into strong cation-exchange groups (i.e., sulfonate groups) in the presence of sodium sulfite. The MCTH and MCTH-g-p(GMA)-SO3H beads were characterized by ATR-FTIR, SEM, and VSM. The sulphonate groups content of the modified MCTH-g-p(GMA)-4 beads was found to be 0.53mmolg(-1) of beads by the potentiometric titration method. The MCTH-g-p(GMA)-SO3H beads were first used as an ion-exchange support for adsorption of lysozyme from aqueous solution. The influence of different experimental parameters such as pH, contact time, and temperature on the adsorption process was evaluated. The maximum adsorption capacity was found to be 208.7mgg(-1) beads. Adsorption of lysozyme on the MCTH-g-p(GMA)-SO3H beads fitted to Langmuir isotherm model and followed the pseudo second-order kinetic. More than 93% of the adsorbed lysozyme was desorbed using Na2CO3 solution (pH 11.0). The purity of the lysozyme was checked by HPLC and SDS gel electrophoresis. In addition, the MCTH-g-p(GMA)-SO3H beads prepared in this work showed promising potential for separation of various anionic molecules. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. A novel automated device for rapid nucleic acid extraction utilizing a zigzag motion of magnetic silica beads

    International Nuclear Information System (INIS)

    Yamaguchi, Akemi; Matsuda, Kazuyuki; Uehara, Masayuki; Honda, Takayuki; Saito, Yasunori

    2016-01-01

    We report a novel automated device for nucleic acid extraction, which consists of a mechanical control system and a disposable cassette. The cassette is composed of a bottle, a capillary tube, and a chamber. After sample injection in the bottle, the sample is lysed, and nucleic acids are adsorbed on the surface of magnetic silica beads. These magnetic beads are transported and are vibrated through the washing reagents in the capillary tube under the control of the mechanical control system, and thus, the nucleic acid is purified without centrifugation. The purified nucleic acid is automatically extracted in 3 min for the polymerase chain reaction (PCR). The nucleic acid extraction is dependent on the transport speed and the vibration frequency of the magnetic beads, and optimizing these two parameters provided better PCR efficiency than the conventional manual procedure. There was no difference between the detection limits of our novel device and that of the conventional manual procedure. We have already developed the droplet-PCR machine, which can amplify and detect specific nucleic acids rapidly and automatically. Connecting the droplet-PCR machine to our novel automated extraction device enables PCR analysis within 15 min, and this system can be made available as a point-of-care testing in clinics as well as general hospitals. - Highlights: • Automatic nucleic acid extraction is performed in 3 min. • Zigzag motion of magnetic silica beads yields rapid and efficient extraction. • The present our device provides better performance than the conventional procedure.

  18. [Development of new magnetic bead separation and purification instrument].

    Science.gov (United States)

    Xu, Yingyuan; Chen, Yi

    2014-05-01

    The article describes the development of new magnetic bead separation and purification instrument. The main application of the instrument is to capture tubercle bacillus from sputum. It is a pretreatment instrument and provides a new platform to help doctors to diagnose bacillary phthisis. Not only could it be used for tubercle bacillus capturing, but also for gene, protein and cell separating and purification. Because the controller of the instrument is 16-bit single chip microcomputer, the cost could be greatly reduced and it will be widely used in China.

  19. Integration of antibody by surface functionalization of graphite-encapsulated magnetic beads using ammonia gas plasma technology for capturing influenza A virus.

    Science.gov (United States)

    Sakudo, Akikazu; Chou, Han; Ikuta, Kazuyoshi; Nagatsu, Masaaki

    2015-05-01

    Antibody-integrated magnetic beads have been functionalized for influenza A virus capture. First, ammonia plasma produced by a radio frequency power source was reacted with the surface of graphite-encapsulated magnetic beads to introduce amino groups. Anti-influenza A virus hemagglutinin antibody was then anchored by its surface sulfide groups to the amino groups on the beads via N-succinimidyl 3-(2-pyridyldithio) propionate. After incubation with influenza A virus, adsorption of the virus to the beads was confirmed by immunochromatography, polymerase chain reaction (PCR), enzyme-linked immunosorbent assay (ELISA), and inoculation of chicken embryonated eggs, indicating that virus infectivity is maintained and that the proposed method is useful for the enhanced detection and isolation of influenza A virus. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Polyvinyl-alcohol-based magnetic beads for rapid and efficient separation of specific or unspecific nucleic acid sequences

    International Nuclear Information System (INIS)

    Oster, J.; Parker, Jeffrey; Brassard, Lothar

    2001-01-01

    The versatile application of polyvinyl-alcohol-based magnetic M-PVA beads is demonstrated in the separation of genomic DNA, sequence specific nucleic acid purification, and binding of bacteria for subsequent DNA extraction and detection. It is shown that nucleic acids can be obtained in high yield and purity using M-PVA beads, making sample preparation efficient, fast and highly adaptable for automation processes

  1. Automated solid-phase subcloning based on beads brought into proximity by magnetic force.

    Science.gov (United States)

    Hudson, Elton P; Nikoshkov, Andrej; Uhlen, Mathias; Rockberg, Johan

    2012-01-01

    In the fields of proteomics, metabolic engineering and synthetic biology there is a need for high-throughput and reliable cloning methods to facilitate construction of expression vectors and genetic pathways. Here, we describe a new approach for solid-phase cloning in which both the vector and the gene are immobilized to separate paramagnetic beads and brought into proximity by magnetic force. Ligation events were directly evaluated using fluorescent-based microscopy and flow cytometry. The highest ligation efficiencies were obtained when gene- and vector-coated beads were brought into close contact by application of a magnet during the ligation step. An automated procedure was developed using a laboratory workstation to transfer genes into various expression vectors and more than 95% correct clones were obtained in a number of various applications. The method presented here is suitable for efficient subcloning in an automated manner to rapidly generate a large number of gene constructs in various vectors intended for high throughput applications.

  2. Yersinia pestis detection by loop-mediated isothermal amplification combined with magnetic bead capture of DNA

    Directory of Open Access Journals (Sweden)

    Na Feng

    Full Text Available ABSTRACT We developed a loop-mediated isothermal amplification (LAMP assay for the detection of Y. pestis by targeting the 3a sequence on chromosome. All 11 species of the genus Yersinia were used to evaluate the specificity of LAMP and PCR, demonstrating that the primers had a high level of specificity. The sensitivity of LAMP or PCR was 2.3 or 23 CFU for pure culture, whereas 2.3 × 104 or 2.3 × 106 CFU for simulated spleen and lung samples. For simulated liver samples, the sensitivity of LAMP was 2.3 × 106 CFU, but PCR was negative at the level of 2.3 × 107 CFU. After simulated spleen and lung samples were treated with magnetic beads, the sensitivity of LAMP or PCR was 2.3 × 103 or 2.3 × 106 CFU, whereas 2.3 × 105 or 2.3 × 107 CFU for magnetic bead-treated liver samples. These results indicated that some components in the tissues could inhibit LAMP and PCR, and liver tissue samples had a stronger inhibition to LAMP and PCR than spleen and lung tissue samples. LAMP has a higher sensitivity than PCR, and magnetic bead capture of DNAs could remarkably increase the sensitivity of LAMP. LAMP is a simple, rapid and sensitive assay suitable for application in the field or poverty areas.

  3. A magnetic bead-based method for concentrating DNA from human urine for downstream detection.

    Directory of Open Access Journals (Sweden)

    Hali Bordelon

    Full Text Available Due to the presence of PCR inhibitors, PCR cannot be used directly on most clinical samples, including human urine, without pre-treatment. A magnetic bead-based strategy is one potential method to collect biomarkers from urine samples and separate the biomarkers from PCR inhibitors. In this report, a 1 mL urine sample was mixed within the bulb of a transfer pipette containing lyophilized nucleic acid-silica adsorption buffer and silica-coated magnetic beads. After mixing, the sample was transferred from the pipette bulb to a small diameter tube, and captured biomarkers were concentrated using magnetic entrainment of beads through pre-arrayed wash solutions separated by small air gaps. Feasibility was tested using synthetic segments of the 140 bp tuberculosis IS6110 DNA sequence spiked into pooled human urine samples. DNA recovery was evaluated by qPCR. Despite the presence of spiked DNA, no DNA was detectable in unextracted urine samples, presumably due to the presence of PCR inhibitors. However, following extraction with the magnetic bead-based method, we found that ∼50% of spiked TB DNA was recovered from human urine containing roughly 5×10(3 to 5×10(8 copies of IS6110 DNA. In addition, the DNA was concentrated approximately ten-fold into water. The final concentration of DNA in the eluate was 5×10(6, 14×10(6, and 8×10(6 copies/µL for 1, 3, and 5 mL urine samples, respectively. Lyophilized and freshly prepared reagents within the transfer pipette produced similar results, suggesting that long-term storage without refrigeration is possible. DNA recovery increased with the length of the spiked DNA segments from 10±0.9% for a 75 bp DNA sequence to 42±4% for a 100 bp segment and 58±9% for a 140 bp segment. The estimated LOD was 77 copies of DNA/µL of urine. The strategy presented here provides a simple means to achieve high nucleic acid recovery from easily obtained urine samples, which does not contain inhibitors of PCR.

  4. Heat generation ability in AC magnetic field of nano MgFe2O4-based ferrite powder prepared by bead milling

    International Nuclear Information System (INIS)

    Hirazawa, Hideyuki; Aono, Hiromichi; Naohara, Takashi; Maehara, Tsunehiro; Sato, Mitsunori; Watanabe, Yuji

    2011-01-01

    Nanosized MgFe 2 O 4 -based ferrite powder having heat generation ability in an AC magnetic field was prepared by bead milling and studied for thermal coagulation therapy applications. The crystal size and the particle size significantly decreased by bead milling. The heat generation ability in an AC magnetic field improved with the milling time, i.e. a decrease in crystal size. However, the heat generation ability decreased for excessively milled samples with crystal sizes of less than 5.5 nm. The highest heat ability (ΔT=34 o C) in the AC magnetic field (370 kHz, 1.77 kA/m) was obtained for fine MgFe 2 O 4 powder having a ca. 6 nm crystal size (the samples were milled for 6-8 h using 0.1 mm φ beads). The heat generation of the samples was closely related to hysteresis loss, a B-H magnetic property. The reason for the high heat generation properties of the samples milled for 6-8 h using 0.1 mm φ beads was ascribed to the increase in hysteresis loss by the formation of a single domain. Moreover, the improvement in heating ability was obtained by calcination of the bead-milled sample at low temperature. In this case, the maximum heat generation (ΔT=41 o C) ability was obtained for a ca. 11 nm crystal size sample was prepared by crystal growth during the sample calcination. On the other hand, the ΔT value for Mg 0.5 Ca 0.5 Fe 2 O 4 was synthesized using a reverse precipitation method decreased by bead milling. - Research Highlights: →The crystal and particle size for MgFe 2 O 4 based ferrite were decreased by bead milling. →The highest heat ability was obtained for MgFe 2 O 4 having a ca. 6 nm crystal size. →This high heat generation ability was ascribed to the increase in hysteresis loss. →Hysteresis loss was increased by the formation of a single domain.

  5. A tosyl-activated magnetic bead cellulose as solid support for sensitive protein detection

    Czech Academy of Sciences Publication Activity Database

    Yan, J.; Horák, Daniel; Lenfeld, Jiří; Hammond, M.; Kamali-Moghaddam, M.

    2013-01-01

    Roč. 167, č. 3 (2013), s. 235-240 ISSN 0168-1656 R&D Projects: GA ČR GAP503/10/0664; GA MŠk 7E12054 EU Projects: European Commission(XE) 259796 - DIATOOLS Institutional support: RVO:61389013 Keywords : bead cellulose * magnetic * protein detection Subject RIV: CD - Macromolecular Chemistry Impact factor: 2.884, year: 2013

  6. Efficient isolation of pure and functional mitochondria from mouse tissues using automated tissue disruption and enrichment with anti-TOM22 magnetic beads.

    Directory of Open Access Journals (Sweden)

    Andras Franko

    Full Text Available To better understand molecular mechanisms regulating changes in metabolism, as observed e.g. in diabetes or neuronal disorders, the function of mitochondria needs to be precisely determined. The usual isolation methods such as differential centrifugation result in isolates of highly variable quality and quantity. To fulfill the need of a reproducible isolation method from solid tissues, which is suitable to handle parallel samples simultaneously, we developed a protocol based on anti-TOM22 (translocase of outer mitochondrial membrane 22 homolog antibody-coupled magnetic beads. To measure oxygen consumption rate in isolated mitochondria from various mouse tissues, a traditional Clark electrode and the high-throughput XF Extracellular Flux Analyzer were used. Furthermore, Western blots, transmission electron microscopic and proteomic studies were performed to analyze the purity and integrity of the mitochondrial preparations. Mitochondrial fractions isolated from liver, brain and skeletal muscle by anti-TOM22 magnetic beads showed oxygen consumption capacities comparable to previously reported values and little contamination with other organelles. The purity and quality of isolated mitochondria using anti-TOM22 magnetic beads was compared to traditional differential centrifugation protocol in liver and the results indicated an obvious advantage of the magnetic beads method compared to the traditional differential centrifugation technique.

  7. Controlled torque on superparamagnetic beads for functional biosensors

    NARCIS (Netherlands)

    Janssen, X.J.A.; Schellekens, A.J.; van Ommering, K.; IJzendoorn, van L.J.; Prins, M.W.J.

    2009-01-01

    We demonstrate that a rotating magnetic field can be used to apply a controlled torque on superparamagnetic beads which leads to a tunable bead rotation frequency in fluid. Smooth rotation is obtained for field rotation frequencies many orders of magnitude higher than the bead rotation frequency. A

  8. Multiscale evaluation of cellular adhesion alteration and cytoskeleton remodeling by magnetic bead twisting.

    Science.gov (United States)

    Isabey, Daniel; Pelle, Gabriel; André Dias, Sofia; Bottier, Mathieu; Nguyen, Ngoc-Minh; Filoche, Marcel; Louis, Bruno

    2016-08-01

    Cellular adhesion forces depend on local biological conditions meaning that adhesion characterization must be performed while preserving cellular integrity. We presently postulate that magnetic bead twisting provides an appropriate stress, i.e., basically a clamp, for assessment in living cells of both cellular adhesion and mechanical properties of the cytoskeleton. A global dissociation rate obeying a Bell-type model was used to determine the natural dissociation rate ([Formula: see text]) and a reference stress ([Formula: see text]). These adhesion parameters were determined in parallel to the mechanical properties for a variety of biological conditions in which either adhesion or cytoskeleton was selectively weakened or strengthened by changing successively ligand concentration, actin polymerization level (by treating with cytochalasin D), level of exerted stress (by increasing magnetic torque), and cell environment (by using rigid and soft 3D matrices). On the whole, this multiscale evaluation of the cellular and molecular responses to a controlled stress reveals an evolution which is consistent with stochastic multiple bond theories and with literature results obtained with other molecular techniques. Present results confirm the validity of the proposed bead-twisting approach for its capability to probe cellular and molecular responses in a variety of biological conditions.

  9. Francisella tularensis detection using magnetic labels and a magnetic biosensor based on frequency mixing

    International Nuclear Information System (INIS)

    Meyer, Martin H.F.; Krause, Hans-Joachim; Hartmann, Markus; Miethe, Peter; Oster, Juergen; Keusgen, Michael

    2007-01-01

    A biosensor that uses resonant coils with a special frequency-mixing technique and magnetic beads as detectable labels has been established for the detection of Francisella tularensis, the causative agent for tularemia. The detection principle is based on a sandwich immunoassay using an anti-Ft antibody for immunofiltration immobilized to ABICAP[reg] polyethylene filters, and biotinylated with streptavidin-coated magnetic beads as labels. The linear detection range of this biosensor was found to be 10 4 -10 6 cfu F. tularensis lipopolysaccharide (LPS) per ml. Tested sample matrices were physiological PBS buffer and rabbit serum

  10. Highly specific and rapid immuno-fluorescent visualization and detection of E. coli O104:H4 with protein-A coated magnetic beads based LST-MUG assay.

    Science.gov (United States)

    Barizuddin, Syed; Balakrishnan, Baskar; Stringer, R Cody; Dweik, Majed

    2015-08-01

    A method combining immunomagnetic separation and fluorescent sensing was developed to detect Escherichia coli (E. coli) O104:H4. The antibody specific to E. coli O104:H4 was immobilized on protein A-coated magnetic beads. This protein-A-anti E. coli O104:H4 complex was used to bind Fluorescein IsoThioCyanate (FITC) labeled E. coli O104:H4 antigen (whole cell) on it. The goal was to achieve a fluorescently detectable protein-A-anti E. coli O104:H4-E. coli O104:H4 complex on the magnetic beads. Fluorescent microscopy was used to image the magnetic beads. The resulting fluorescence on the beads was due to the FITC labeled antigen binding on the protein-A-anti E. coli O104:H4 immobilized magnetic beads. This visually proves the antigen-antibody binding. The fluorescent imaging results were obtained in 2 h if the minimum available bacteria in the sample were at least 10(5) CFU/ml. If no fluorescence was observed on the magnetic beads during fluorescent imaging, it indicates the bacterial concentration in the sample to be too low for it to have bound to the magnetic beads and hence no detection was possible. To detect bacterial concentration less than 10(5) CFU/ml in the sample, an additional step was required for detection. The magnetic bead complex was added to the LST-MUG (lauryl sulfate tryptose-4-methylumbelliferyl-β-D-glucuronide), a signaling reporter. The E. coli O104:H4 grows in LST-MUG and releases β-glucuronidase enzyme. This enzyme cleaves the MUG substrate that produces 4-methylumbelliferone, a highly fluorescent species. This fluorescence was detected using a spectrofluorometer. The emission peak in the fluorescent spectrum was found to be at 450 nm. The lower and upper detection range for this LST-MUG assay was found to be 2.05×10(5)-4.09×10(8) CFU/ml. The results for the LST-MUG assay for concentrations below 10(5) CFU/ml were ascertained in 8h. The advantages of this technique include the specific detection of bacteria without an enrichment step and

  11. Francisella tularensis detection using magnetic labels and a magnetic biosensor based on frequency mixing

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, Martin H.F. [Institute for Pharmaceutical Chemistry, Philipps-Universitaet Marburg (Germany); Krause, Hans-Joachim [Institute of Bio-and Nanosystems (IBN-2), Research Center Juelich (Germany); Hartmann, Markus [Institute for Pharmaceutical Chemistry, Philipps-Universitaet Marburg (Germany); Miethe, Peter [SENOVA GmbH, Jena (Germany); Oster, Juergen [chemagen GmbH, Baesweiler (Germany); Keusgen, Michael [Institute for Pharmaceutical Chemistry, Philipps-Universitaet Marburg (Germany)]. E-mail: Keusgen@staff.uni-marburg.de

    2007-04-15

    A biosensor that uses resonant coils with a special frequency-mixing technique and magnetic beads as detectable labels has been established for the detection of Francisella tularensis, the causative agent for tularemia. The detection principle is based on a sandwich immunoassay using an anti-Ft antibody for immunofiltration immobilized to ABICAP[reg] polyethylene filters, and biotinylated with streptavidin-coated magnetic beads as labels. The linear detection range of this biosensor was found to be 10{sup 4}-10{sup 6} cfu F. tularensis lipopolysaccharide (LPS) per ml. Tested sample matrices were physiological PBS buffer and rabbit serum.

  12. Effect of algal density in bead, bead size and bead concentrations ...

    African Journals Online (AJOL)

    Effect of algal density in bead, bead size and bead concentrations on wastewater nutrient removal. ... African Journal of Biotechnology ... The bioreactor containing algal beads (4 mm diameter) with 1.5 x 106 cells bead-1 (cell stocking) at concentration of 10.66 beads ml-1 wastewater (1:3 bead: wastewater, v/v) achieved ...

  13. Magnet polepiece design for uniform magnetic force on superparamagnetic beads

    OpenAIRE

    Fallesen, Todd; Hill, David B.; Steen, Matthew; Macosko, Jed C.; Bonin, Keith; Holzwarth, George

    2010-01-01

    Here we report construction of a simple electromagnet with novel polepieces which apply a spatially uniform force to superparamagnetic beads in an optical microscope. The wedge-shaped gap was designed to keep ∂Bx∕∂y constant and B large enough to saturate the bead. We achieved fields of 300–600 mT and constant gradients of 67 T∕m over a sample space of 0.5×4 mm2 in the focal plane of the microscope and 0.05 mm along the microscope optic axis. Within this space the maximum force on a 2.8 μm di...

  14. Magnetic shielding for coreless linear permanent magnet motors

    NARCIS (Netherlands)

    Pluk, K.J.W.; Jansen, J.W.; Lomonova, E.

    2013-01-01

    This paper concerns the local reduction of the magnetic flux density by means of magnetic shielding. Using a spatial frequency description, a 2-D semi-analytical periodic model is obtained for a coreless single-sided linear permanent magnet motor. The magnetic shield is included in the modeling

  15. Three-bead steering microswimmers

    Science.gov (United States)

    Rizvi, Mohd Suhail; Farutin, Alexander; Misbah, Chaouqi

    2018-02-01

    The self-propelled microswimmers have recently attracted considerable attention as model systems for biological cell migration as well as artificial micromachines. A simple and well-studied microswimmer model consists of three identical spherical beads joined by two springs in a linear fashion with active oscillatory forces being applied on the beads to generate self-propulsion. We have extended this linear microswimmer configuration to a triangular geometry where the three beads are connected by three identical springs in an equilateral triangular manner. The active forces acting on each spring can lead to autonomous steering motion; i.e., allowing the swimmer to move along arbitrary paths. We explore the microswimmer dynamics analytically and pinpoint its rich character depending on the nature of the active forces. The microswimmers can translate along a straight trajectory, rotate at a fixed location, as well as perform a simultaneous translation and rotation resulting in complex curved trajectories. The sinusoidal active forces on the three springs of the microswimmer contain naturally four operating parameters which are more than required for the steering motion. We identify the minimal operating parameters which are essential for the motion of the microswimmer along any given arbitrary trajectory. Therefore, along with providing insights into the mechanics of the complex motion of the natural and artificial microswimmers, the triangular three-bead microswimmer can be utilized as a model for targeted drug delivery systems and autonomous underwater vehicles where intricate trajectories are involved.

  16. Fabrication of magnetic alginate beads with uniform dispersion of CoFe2O4 by the polydopamine surface functionalization for organic pollutants removal

    Science.gov (United States)

    Li, Xiaoli; Lu, Haijun; Zhang, Yun; He, Fu; Jing, Lingyun; He, Xinghua

    2016-12-01

    A simple and efficient method for production of magnetic composites by decorating CoFe2O4 with polydopamine (PDA) through oxidative polymerization of dopamine was conducted. Further, magnetic alginate beads with porous structure containing well-dispersed CoFe2O4-PDA were fabricated by ionic crosslinking technology. The resulting SA@CoFe2O4-PDA beads were characterized using scanning electron microscopy, Fourier transform infrared spectrometry, X-ray diffractometer, vibrating sample magnetometer and X-ray photoelectron spectroscopy. Adsorption potential of SA@CoFe2O4-PDA beads for organic dyes including Methylene Blue (MB), Crystal Violet (CV) and Malachite Green (MG) was evaluated. SA@CoFe2O4-PDA beads exhibited excellent adsorption performances due to the composite effect, large surface area and porous structure. Organic dyes could be removed from water solution with high efficiency in a wide pH range of 4.0-9.0. Moreover, it exhibited much higher adsorptivity towards MB and CV with the maximum adsorption capacities of 466.60 and 456.52 mg/g, respectively, which were much higher than that of MG (248.78 mg/g). Ca-electrolyte had obvious adverse effects on MB and CV adsorption than MG. FTIR and XPS demonstrated that carboxylate, catechol, hydroxyl and amine groups might be involved in adsorption of organic dyes. The characteristics of wide pH range, high adsorption capacity and convenient magnetic separation would make SA@CoFe2O4-PDA beads as effective adsorbent for removal of organic dyes from wastewater.

  17. Separation of magnetic beads in a hybrid continuous flow microfluidic device

    Energy Technology Data Exchange (ETDEWEB)

    Samanta, Abhishek [Haldia Institute of Technology, Production Engineering Department, Haldia (India); Ganguly, Ranjan; Datta, Amitava [Jadavpur University, Power Engineering Department (India); Modak, Nipu, E-mail: nmechju@gmail.com [Jadavpur University, Mechanical Engineering Department (India)

    2017-04-01

    Magnetic separation of biological entities in microfluidic environment is a key task for a large number of bio-analytical protocols. In magnetophoretic separation, biochemically functionalized magnetic beads are allowed to bind selectively to target analytes, which are then separated from the background stream using a suitably imposed magnetic field. Here we present a numerical study, characterizing the performance of a magnetophoretic hybrid microfluidic device having two inlets and three outlets for immunomagnetic isolation of three different species from a continuous flow. The hybrid device works on the principle of split-flow thin (SPLITT) fractionation and field flow fractionation (FFF) mechanisms. Transport of the magnetic particles in the microchannel has been predicted following an Eulerian-Lagrangian model and using an in-house numerical code. Influence of the salient geometrical parameters on the performance of the separator is studied by characterizing the particle trajectories and their capture and separation indices. Finally, optimum channel geometry is identified that yields the maximum capture efficiency and separation index. - Highlights: • Immunomagnetic separation in a hybrid microchannel design is investigated numerically. • Influence of salient geometric parameters on the device performance is analysed. • Optimum device dimension for best separation parameters are identified. • Optimized design of hybrid separator performs better than FFF or SPLITT devices.

  18. Improved Peak Capacity for Capillary Electrophoretic Separations of Enzyme Inhibitors with Activity-Based Detection Using Magnetic Bead Microreactors

    Science.gov (United States)

    Yan, Xiaoyan; Gilman, S. Douglass

    2010-01-01

    A technique for separating and detecting enzyme inhibitors was developed using capillary electrophoresis with an enzyme microreactor. The on-column enzyme microreactor was constructed using NdFeB magnet(s) to immobilize alkaline phosphatase-coated superparamagnetic beads (2.8 μm diameter) inside a capillary before the detection window. Enzyme inhibition assays were performed by injecting a plug of inhibitor into a capillary filled with the substrate, AttoPhos. Product generated in the enzyme microreactor was detected by laser-induced fluorescence. Inhibitor zones electrophoresed through the capillary, passed through the enzyme microreactor, and were observed as negative peaks due to decreased product formation. The goal of this study was to improve peak capacities for inhibitor separations relative to previous work, which combined continuous engagement electrophoretically mediated microanalysis (EMMA) and transient engagement EMMA to study enzyme inhibition. The effects of electric field strength, bead injection time and inhibitor concentrations on peak capacity and peak width were investigated. Peak capacities were increased to ≥20 under optimal conditions of electric field strength and bead injection time for inhibition assays with arsenate and theophylline. Five reversible inhibitors of alkaline phosphatase (theophylline, vanadate, arsenate, L-tryptophan and tungstate) were separated and detected to demonstrate the ability of this technique to analyze complex inhibitor mixtures. PMID:20024913

  19. Ferrite bead effect on Class-D amplifier audio quality

    OpenAIRE

    Haddad , Kevin El; Mrad , Roberto; Morel , Florent; Pillonnet , Gael; Vollaire , Christian; Nagari , Angelo

    2014-01-01

    International audience; This paper studies the effect of ferrite beads on the audio quality of Class-D audio amplifiers. This latter is a switch-ing circuit which creates high frequency harmonics. Generally, a filter is used at the amplifier output for the sake of electro-magnetic compatibility (EMC). So often, in integrated solutions, this filter contains ferrite beads which are magnetic components and present nonlinear behavior. Time domain measurements and their equivalence in frequency do...

  20. On-Chip Magnetic Bead Manipulation and Detection Using a Magnetoresistive Sensor-Based Micro-Chip: Design Considerations and Experimental Characterization

    KAUST Repository

    Gooneratne, Chinthaka Pasan; Kodzius, Rimantas; Li, Fuquan; Foulds, Ian G.; Kosel, Jü rgen

    2016-01-01

    The remarkable advantages micro-chip platforms offer over cumbersome, time-consuming equipment currently in use for bio-analysis are well documented. In this research, a micro-chip that includes a unique magnetic actuator (MA) for the manipulation of superparamagnetic beads (SPBs), and a magnetoresistive sensor for the detection of SPBs is presented. A design methodology, which takes into account the magnetic volume of SPBs, diffusion and heat transfer phenomena, is presented with the aid of numerical analysis to optimize the parameters of the MA. The MA was employed as a magnetic flux generator and experimental analysis with commercially available COMPEL™ and Dynabeads® demonstrated the ability of the MA to precisely transport a small number of SPBs over long distances and concentrate SPBs to a sensing site for detection. Moreover, the velocities of COMPEL™ and Dynabead® SPBs were correlated to their magnetic volumes and were in good agreement with numerical model predictions. We found that 2.8 μm Dynabeads® travel faster, and can be attracted to a magnetic source from a longer distance, than 6.2 μm COMPEL™ beads at magnetic flux magnitudes of less than 10 mT. The micro-chip system could easily be integrated with electronic circuitry and microfluidic functions, paving the way for an on-chip biomolecule quantification device

  1. On-Chip Magnetic Bead Manipulation and Detection Using a Magnetoresistive Sensor-Based Micro-Chip: Design Considerations and Experimental Characterization

    KAUST Repository

    Gooneratne, Chinthaka Pasan

    2016-08-26

    The remarkable advantages micro-chip platforms offer over cumbersome, time-consuming equipment currently in use for bio-analysis are well documented. In this research, a micro-chip that includes a unique magnetic actuator (MA) for the manipulation of superparamagnetic beads (SPBs), and a magnetoresistive sensor for the detection of SPBs is presented. A design methodology, which takes into account the magnetic volume of SPBs, diffusion and heat transfer phenomena, is presented with the aid of numerical analysis to optimize the parameters of the MA. The MA was employed as a magnetic flux generator and experimental analysis with commercially available COMPEL™ and Dynabeads® demonstrated the ability of the MA to precisely transport a small number of SPBs over long distances and concentrate SPBs to a sensing site for detection. Moreover, the velocities of COMPEL™ and Dynabead® SPBs were correlated to their magnetic volumes and were in good agreement with numerical model predictions. We found that 2.8 μm Dynabeads® travel faster, and can be attracted to a magnetic source from a longer distance, than 6.2 μm COMPEL™ beads at magnetic flux magnitudes of less than 10 mT. The micro-chip system could easily be integrated with electronic circuitry and microfluidic functions, paving the way for an on-chip biomolecule quantification device

  2. On-Chip Magnetic Bead Manipulation and Detection Using a Magnetoresistive Sensor-Based Micro-Chip: Design Considerations and Experimental Characterization

    Directory of Open Access Journals (Sweden)

    Chinthaka P. Gooneratne

    2016-08-01

    Full Text Available The remarkable advantages micro-chip platforms offer over cumbersome, time-consuming equipment currently in use for bio-analysis are well documented. In this research, a micro-chip that includes a unique magnetic actuator (MA for the manipulation of superparamagnetic beads (SPBs, and a magnetoresistive sensor for the detection of SPBs is presented. A design methodology, which takes into account the magnetic volume of SPBs, diffusion and heat transfer phenomena, is presented with the aid of numerical analysis to optimize the parameters of the MA. The MA was employed as a magnetic flux generator and experimental analysis with commercially available COMPEL™ and Dynabeads® demonstrated the ability of the MA to precisely transport a small number of SPBs over long distances and concentrate SPBs to a sensing site for detection. Moreover, the velocities of COMPEL™ and Dynabead® SPBs were correlated to their magnetic volumes and were in good agreement with numerical model predictions. We found that 2.8 μm Dynabeads® travel faster, and can be attracted to a magnetic source from a longer distance, than 6.2 μm COMPEL™ beads at magnetic flux magnitudes of less than 10 mT. The micro-chip system could easily be integrated with electronic circuitry and microfluidic functions, paving the way for an on-chip biomolecule quantification device.

  3. Effect of algal density in bead, bead size and bead concentrations ...

    African Journals Online (AJOL)

    Laboratory experiments were performed to study nitrogen and phosphorus uptake by the unicellular green microalga Chlorella vulgaris immobilized in calcium alginate beads. Different cell stockings in beads, different bead sizes and different algal bead concentrations in wastewaters were tested. Significant higher nutrients ...

  4. Novel highly porous magnetic hydrogel beads composed of chitosan and sodium citrate: an effective adsorbent for the removal of heavy metals from aqueous solutions.

    Science.gov (United States)

    Pu, Shengyan; Ma, Hui; Zinchenko, Anatoly; Chu, Wei

    2017-07-01

    This research focuses on the removal of heavy metal ions from aqueous solutions using magnetic chitosan hydrogel beads as a potential sorbent. Highly porous magnetic chitosan hydrogel (PMCH) beads were prepared by a combination of in situ co-precipitation and sodium citrate cross-linking. Fourier transform infrared spectroscopy indicated that the high sorption efficiency of metal cations is attributable to the hydroxyl, amino, and carboxyl groups in PMCH beads. Thermogravimetric analysis demonstrated that introducing Fe 3 O 4 nanoparticles increases the thermal stability of the adsorbent. Laser confocal microscopy revealed highly uniform porous structure of the resultant PMCH beads, which contained a high moisture content (93%). Transmission electron microscopy micrographs showed that the Fe 3 O 4 nanoparticles, with a mean diameter of 5 ± 2 nm, were well dispersed inside the chitosan beads. Batch adsorption experiments and adsorption kinetic analysis revealed that the adsorption process obeys a pseudo-second-order model. Isotherm data were satisfactorily described by the Langmuir equation, and the maximum adsorption capacity of the adsorbent was 84.02 mg/g. Energy-dispersive X-ray spectroscopy and X-ray photoelectron spectra analyses were performed to confirm the adsorption of Pb 2+ and to identify the adsorption mechanism.

  5. Magnetic Bead and Fluorescent Silica Nanoparticles Based Optical Immunodetection of Staphylococcal Enterotoxin B (SEB in Bottled Water

    Directory of Open Access Journals (Sweden)

    Shiva K. RASTOGI

    2009-10-01

    Full Text Available Staphylococcal enterotoxins (SEs are a major cause of food-borne diseases, most commonly SEs assayed immunologically with ELISA. An immunoassay based on fluorescein dye doped silica dioxide nanoparticles (F-SiNPs and magnetic bead (MB is described here for the detection of staphylococcal enterotoxin B (SEB. F-SiNPs have unique optical properties which make them attractive for biosensing. The water-in-oil (W/O reverse microemulsion method was used for the synthesis of F-SiNPs (~ 95 nm of diameter. The F-SiNPs were characterized using SEM, TEM and FTIR spectroscopy. The detection of SEB is preformed in PBS buffer, and bottled drinking water using sandwich immunoassay format. Target analytes were captured using MBs modified with the antigen-specific “capture” antibody, and detected using F-SiNP labeled secondary antigen-specific antibody. We report a limit of detection down to 1 ng/mL SEB spiked sample in less than 2 hr assay time using fluorocount method. This study demonstrates the bio warfare agent SEB capture by magnetic beads and detection using F-SiNPs.

  6. On-bead combinatorial synthesis and imaging of chemical exchange saturation transfer magnetic resonance imaging agents to identify factors that influence water exchange.

    Science.gov (United States)

    Napolitano, Roberta; Soesbe, Todd C; De León-Rodríguez, Luis M; Sherry, A Dean; Udugamasooriya, D Gomika

    2011-08-24

    The sensitivity of magnetic resonance imaging (MRI) contrast agents is highly dependent on the rate of water exchange between the inner sphere of a paramagnetic ion and bulk water. Normally, identifying a paramagnetic complex that has optimal water exchange kinetics is done by synthesizing and testing one compound at a time. We report here a rapid, economical on-bead combinatorial synthesis of a library of imaging agents. Eighty different 1,4,7,10-tetraazacyclododecan-1,4,7,10-tetraacetic acid (DOTA)-tetraamide peptoid derivatives were prepared on beads using a variety of charged, uncharged but polar, hydrophobic, and variably sized primary amines. A single chemical exchange saturation transfer image of the on-bead library easily distinguished those compounds having the most favorable water exchange kinetics. This combinatorial approach will allow rapid screening of libraries of imaging agents to identify the chemical characteristics of a ligand that yield the most sensitive imaging agents. This technique could be automated and readily adapted to other types of MRI or magnetic resonance/positron emission tomography agents as well.

  7. Fabrication of a pen-shaped portable biochemical reaction system based on magnetic bead manipulation

    International Nuclear Information System (INIS)

    Shikida, Mitsuhiro; Inagaki, Noriyuki; Okochi, Mina; Honda, Hiroyuki; Sato, Kazuo

    2011-01-01

    A pen-shaped platform that is similar to a mechanical pencil is proposed for producing a portable reaction system. A reaction unit, as the key component in the system, was produced by using a heat shrinkable tube. A mechanical pencil supplied by Mitsubishi Pencil Co. Ltd was used as the pen-shaped platform for driving the reaction cylinder. It was actuated using an inchworm motion. We confirmed that the magnetic beads were successfully manipulated in the droplet in the cylinder-shaped reaction units. (technical note)

  8. A Magnetic Sensor System for Biological Detection

    KAUST Repository

    Li, Fuquan

    2015-05-01

    Magnetic biosensors detect biological targets through sensing the stray field of magnetic beads which label the targets. Commonly, magnetic biosensors employ the “sandwich” method to immobilize biological targets, i.e., the targets are sandwiched between a bio-functionalized sensor surface and bio-functionalized magnetic beads. This method has been used very successfully in different application, but its execution requires a rather elaborate procedure including several washing and incubation steps. This dissertation investigates a new magnetic biosensor concept, which enables a simple and effective detection of biological targets. The biosensor takes advantage of the size difference between bare magnetic beads and compounds of magnetic beads and biological targets. First, the detection of super-paramagnetic beads via magnetic tunnel junction (MTJ) sensors is implemented. Frequency modulation is used to enhance the signal-to-noise ratio, enabling the detection of a single magnetic bead. Second, the concept of the magnetic biosensor is investigated theoretically. The biosensor consists of an MTJ sensor, which detects the stray field of magnetic beads inside of a trap on top of the MTJ. A microwire between the trap and the MTJ is used to attract magnetic beads to the trapping well by applying a current to it. The MTJ sensor’s output depends on the number of beads inside the trap. If biological targets are in the sample solution, the beads will form bead compounds consisting of beads linked to the biological targets. Since bead compounds are larger than bare beads, the number of beads inside the trapping well will depend on the presence of biological targets. Hence, the output of the MTJ sensor will depend on the biological targets. The dependences of sensor signals on the sizes of the MTJ sensor, magnetic beads and biological targets are studied to find the optimum constellations for the detection of specific biological targets. The optimization is demonstrated

  9. Magnetic bead purification of labeled DNA fragments forhigh-throughput capillary electrophoresis sequencing

    Energy Technology Data Exchange (ETDEWEB)

    Elkin, Christopher; Kapur, Hitesh; Smith, Troy; Humphries, David; Pollard, Martin; Hammon, Nancy; Hawkins, Trevor

    2001-09-15

    We have developed an automated purification method for terminator sequencing products based on a magnetic bead technology. This 384-well protocol generates labeled DNA fragments that are essentially free of contaminates for less than $0.005 per reaction. In comparison to laborious ethanol precipitation protocols, this method increases the phred20 read length by forty bases with various DNA templates such as PCR fragments, Plasmids, Cosmids and RCA products. Our method eliminates centrifugation and is compatible with both the MegaBACE 1000 and ABIPrism 3700 capillary instruments. As of September 2001, this method has produced over 1.6 million samples with 93 percent averaging 620 phred20 bases as part of Joint Genome Institutes Production Process.

  10. Overview of NASA Magnet and Linear Alternator Research Efforts

    Science.gov (United States)

    Geng, Steven M.; Niedra, Janis M.; Schwarze, Gene E.

    2005-02-01

    The Department of Energy, Lockheed Martin, Stirling Technology Company, and NASA Glenn Research Center are developing a high-efficiency, 110 watt Stirling Radioisotope Generator (SRG110) for NASA Space Science missions. NASA Glenn is conducting in-house research on rare earth permanent magnets and on linear alternators to assist in developing a free-piston Stirling convertor for the SRG110 and for developing advanced technology. The permanent magnet research efforts include magnet characterization, short-term magnet aging tests, and long-term magnet aging tests. Linear alternator research efforts have begun just recently at GRC with the characterization of a moving iron type linear alternator using GRC's alternator test rig. This paper reports on the progress and future plans of GRC's magnet and linear alternator research efforts.

  11. Parallel RNA extraction using magnetic beads and a droplet array.

    Science.gov (United States)

    Shi, Xu; Chen, Chun-Hong; Gao, Weimin; Chao, Shih-Hui; Meldrum, Deirdre R

    2015-02-21

    Nucleic acid extraction is a necessary step for most genomic/transcriptomic analyses, but it often requires complicated mechanisms to be integrated into a lab-on-a-chip device. Here, we present a simple, effective configuration for rapidly obtaining purified RNA from low concentration cell medium. This Total RNA Extraction Droplet Array (TREDA) utilizes an array of surface-adhering droplets to facilitate the transportation of magnetic purification beads seamlessly through individual buffer solutions without solid structures. The fabrication of TREDA chips is rapid and does not require a microfabrication facility or expertise. The process takes less than 5 minutes. When purifying mRNA from bulk marine diatom samples, its repeatability and extraction efficiency are comparable to conventional tube-based operations. We demonstrate that TREDA can extract the total mRNA of about 10 marine diatom cells, indicating that the sensitivity of TREDA approaches single-digit cell numbers.

  12. Fabrication of magnetic alginate beads with uniform dispersion of CoFe{sub 2}O{sub 4} by the polydopamine surface functionalization for organic pollutants removal

    Energy Technology Data Exchange (ETDEWEB)

    Li, Xiaoli, E-mail: lixiaoli@lzu.edu.cn [Gansu Key Laboratory for Environmental Pollution Prediction and Control, College of Earth and Environmental Sciences, Lanzhou University, Lanzhou 730000 (China); Lu, Haijun, E-mail: 784616040@qq.com [Gansu Key Laboratory for Environmental Pollution Prediction and Control, College of Earth and Environmental Sciences, Lanzhou University, Lanzhou 730000 (China); Zhang, Yun, E-mail: zhangyun@lzu.edu.cn [Institute of Biochemical Engineering & Environmental Technology, College of Chemistry and Chemical Engineering, Lanzhou University, Lanzhou 730000 (China); He, Fu, E-mail: hef15@lzu.edu.cn [Institute of Biochemical Engineering & Environmental Technology, College of Chemistry and Chemical Engineering, Lanzhou University, Lanzhou 730000 (China); Jing, Lingyun, E-mail: jingly12@lzu.edu.cn [Gansu Key Laboratory for Environmental Pollution Prediction and Control, College of Earth and Environmental Sciences, Lanzhou University, Lanzhou 730000 (China); He, Xinghua, E-mail: 466410250@qq.com [Institute of Biochemical Engineering & Environmental Technology, College of Chemistry and Chemical Engineering, Lanzhou University, Lanzhou 730000 (China)

    2016-12-15

    Highlights: • SA@CoFe{sub 2}O{sub 4}-PDA with magnetic particles and biopolymers were used for dye removal. • SA@CoFe{sub 2}O{sub 4}-PDA exhibited the synergistic effect. • High adsorption capacities and fast kinetics were obtained. • Cationic dyes could be removed with high efficiency in a wide pH range. • Possible mechanism of adsorption was investigated. - Abstract: A simple and efficient method for production of magnetic composites by decorating CoFe{sub 2}O{sub 4} with polydopamine (PDA) through oxidative polymerization of dopamine was conducted. Further, magnetic alginate beads with porous structure containing well-dispersed CoFe{sub 2}O{sub 4}-PDA were fabricated by ionic crosslinking technology. The resulting SA@CoFe{sub 2}O{sub 4}-PDA beads were characterized using scanning electron microscopy, Fourier transform infrared spectrometry, X-ray diffractometer, vibrating sample magnetometer and X-ray photoelectron spectroscopy. Adsorption potential of SA@CoFe{sub 2}O{sub 4}-PDA beads for organic dyes including Methylene Blue (MB), Crystal Violet (CV) and Malachite Green (MG) was evaluated. SA@CoFe{sub 2}O{sub 4}-PDA beads exhibited excellent adsorption performances due to the composite effect, large surface area and porous structure. Organic dyes could be removed from water solution with high efficiency in a wide pH range of 4.0–9.0. Moreover, it exhibited much higher adsorptivity towards MB and CV with the maximum adsorption capacities of 466.60 and 456.52 mg/g, respectively, which were much higher than that of MG (248.78 mg/g). Ca-electrolyte had obvious adverse effects on MB and CV adsorption than MG. FTIR and XPS demonstrated that carboxylate, catechol, hydroxyl and amine groups might be involved in adsorption of organic dyes. The characteristics of wide pH range, high adsorption capacity and convenient magnetic separation would make SA@CoFe{sub 2}O{sub 4}-PDA beads as effective adsorbent for removal of organic dyes from wastewater.

  13. A planar conducting micro-loop structure for transportation of magnetic beads: An approach towards rapid sensing and quantification of biological entities

    KAUST Repository

    Gooneratne, Chinthaka Pasan; Giouroudi, Ioanna; Kosel, Jü rgen

    2012-01-01

    tools for accurate and rapid cell sorting and counting. Effective manipulation of beads is a critical factor for the performance of LOC devices. In this paper we propose a planar conducting micro-loop structure to trap, manipulate and transport magnetic

  14. Electrochemical immunoassay using magnetic beads for the determination of zearalenone in baby food: An anticipated analytical tool for food safety

    International Nuclear Information System (INIS)

    Hervas, Miriam; Lopez, Miguel Angel; Escarpa, Alberto

    2009-01-01

    In this work, electrochemical immunoassay involving magnetic beads to determine zearalenone in selected food samples has been developed. The immunoassay scheme has been based on a direct competitive immunoassay method in which antibody-coated magnetic beads were employed as the immobilisation support and horseradish peroxidase (HRP) was used as enzymatic label. Amperometric detection has been achieved through the addition of hydrogen peroxide substrate and hydroquinone as mediator. Analytical performance of the electrochemical immunoassay has been evaluated by analysis of maize certified reference material (CRM) and selected baby food samples. A detection limit (LOD) of 0.011 μg L -1 and EC 50 0.079 μg L -1 were obtained allowing the assessment of the detection of zearalenone mycotoxin. In addition, an excellent accuracy with a high recovery yield ranging between 95 and 108% has been obtained. The analytical features have shown the proposed electrochemical immunoassay to be a very powerful and timely screening tool for the food safety scene.

  15. Electrochemical immunoassay using magnetic beads for the determination of zearalenone in baby food: an anticipated analytical tool for food safety.

    Science.gov (United States)

    Hervás, Miriam; López, Miguel Angel; Escarpa, Alberto

    2009-10-27

    In this work, electrochemical immunoassay involving magnetic beads to determine zearalenone in selected food samples has been developed. The immunoassay scheme has been based on a direct competitive immunoassay method in which antibody-coated magnetic beads were employed as the immobilisation support and horseradish peroxidase (HRP) was used as enzymatic label. Amperometric detection has been achieved through the addition of hydrogen peroxide substrate and hydroquinone as mediator. Analytical performance of the electrochemical immunoassay has been evaluated by analysis of maize certified reference material (CRM) and selected baby food samples. A detection limit (LOD) of 0.011 microg L(-1) and EC(50) 0.079 microg L(-1) were obtained allowing the assessment of the detection of zearalenone mycotoxin. In addition, an excellent accuracy with a high recovery yield ranging between 95 and 108% has been obtained. The analytical features have shown the proposed electrochemical immunoassay to be a very powerful and timely screening tool for the food safety scene.

  16. Electrochemical immunoassay using magnetic beads for the determination of zearalenone in baby food: An anticipated analytical tool for food safety

    Energy Technology Data Exchange (ETDEWEB)

    Hervas, Miriam; Lopez, Miguel Angel [Departamento Quimica Analitica, Universidad de Alcala, Ctra. Madrid-Barcelona, Km. 33600, E-28871 Alcala de Henares, Madrid (Spain); Escarpa, Alberto, E-mail: alberto.escarpa@uah.es [Departamento Quimica Analitica, Universidad de Alcala, Ctra. Madrid-Barcelona, Km. 33600, E-28871 Alcala de Henares, Madrid (Spain)

    2009-10-27

    In this work, electrochemical immunoassay involving magnetic beads to determine zearalenone in selected food samples has been developed. The immunoassay scheme has been based on a direct competitive immunoassay method in which antibody-coated magnetic beads were employed as the immobilisation support and horseradish peroxidase (HRP) was used as enzymatic label. Amperometric detection has been achieved through the addition of hydrogen peroxide substrate and hydroquinone as mediator. Analytical performance of the electrochemical immunoassay has been evaluated by analysis of maize certified reference material (CRM) and selected baby food samples. A detection limit (LOD) of 0.011 {mu}g L{sup -1} and EC{sub 50} 0.079 {mu}g L{sup -1} were obtained allowing the assessment of the detection of zearalenone mycotoxin. In addition, an excellent accuracy with a high recovery yield ranging between 95 and 108% has been obtained. The analytical features have shown the proposed electrochemical immunoassay to be a very powerful and timely screening tool for the food safety scene.

  17. Quantitative and multiplexed detection for blood typing based on quantum dot-magnetic bead assay.

    Science.gov (United States)

    Xu, Ting; Zhang, Qiang; Fan, Ya-Han; Li, Ru-Qing; Lu, Hua; Zhao, Shu-Ming; Jiang, Tian-Lun

    2017-01-01

    Accurate and reliable blood grouping is essential for safe blood transfusion. However, conventional methods are qualitative and use only single-antigen detection. We overcame these limitations by developing a simple, quantitative, and multiplexed detection method for blood grouping using quantum dots (QDs) and magnetic beads. In the QD fluorescence assay (QFA), blood group A and B antigens were quantified using QD labeling and magnetic beads, and the blood groups were identified according to the R value (the value was calculated with the fluorescence intensity from dual QD labeling) of A and B antigens. The optimized performance of QFA was established by blood typing 791 clinical samples. Quantitative and multiplexed detection for blood group antigens can be completed within 35 min with more than 10 5 red blood cells. When conditions are optimized, the assay performance is satisfactory for weak samples. The coefficients of variation between and within days were less than 10% and the reproducibility was good. The ABO blood groups of 791 clinical samples were identified by QFA, and the accuracy obtained was 100% compared with the tube test. Receiver-operating characteristic curves revealed that the QFA has high sensitivity and specificity toward clinical samples, and the cutoff points of the R value of A and B antigens were 1.483 and 1.576, respectively. In this study, we reported a novel quantitative and multiplexed method for the identification of ABO blood groups and presented an effective alternative for quantitative blood typing. This method can be used as an effective tool to improve blood typing and further guarantee clinical transfusion safety.

  18. New advances in electrochemical biosensors for the detection of toxins: Nanomaterials, magnetic beads and microfluidics systems. A review

    International Nuclear Information System (INIS)

    Reverté, Laia; Prieto-Simón, Beatriz; Campàs, Mònica

    2016-01-01

    The use of nanotechnology in bioanalytical devices has special advantages in the detection of toxins of interest in food safety and environmental applications. The low levels to be detected and the small size of toxins justify the increasing number of publications dealing with electrochemical biosensors, due to their high sensitivity and design versatility. The incorporation of nanomaterials in their development has been exploited to further increase their sensitivity, providing simple and fast devices, with multiplexed capabilities. This paper gives an overview of the electrochemical biosensors that have incorporated carbon and metal nanomaterials in their configurations for the detection of toxins. Biosensing systems based on magnetic beads or integrated into microfluidics systems have also been considered because of their contribution to the development of compact analytical devices. The roles of these materials, the methods used for their incorporation in the biosensor configurations as well as the advantages they provide to the analyses are summarised. - Highlights: • Nanomaterials improve the performance of electrochemical biosensors. • Carbon nanomaterials can act as electrocatalysts or label supports in biosensors. • Metal nanomaterials can act as nanostructured supports or labels in biosensors. • Magnetic beads are exploited as immobilisation supports and/or label carriers.

  19. New advances in electrochemical biosensors for the detection of toxins: Nanomaterials, magnetic beads and microfluidics systems. A review

    Energy Technology Data Exchange (ETDEWEB)

    Reverté, Laia [IRTA, Carretera Poble Nou km. 5.5, 43540 Sant Carles de la Ràpita, Tarragona (Spain); Prieto-Simón, Beatriz [ARC Centre of Excellence in Convergent Bio-Nano Science and Technology, Future Industries Institute, University of South Australia, SA 5095 (Australia); Campàs, Mònica, E-mail: monica.campas@irta.cat [IRTA, Carretera Poble Nou km. 5.5, 43540 Sant Carles de la Ràpita, Tarragona (Spain)

    2016-02-18

    The use of nanotechnology in bioanalytical devices has special advantages in the detection of toxins of interest in food safety and environmental applications. The low levels to be detected and the small size of toxins justify the increasing number of publications dealing with electrochemical biosensors, due to their high sensitivity and design versatility. The incorporation of nanomaterials in their development has been exploited to further increase their sensitivity, providing simple and fast devices, with multiplexed capabilities. This paper gives an overview of the electrochemical biosensors that have incorporated carbon and metal nanomaterials in their configurations for the detection of toxins. Biosensing systems based on magnetic beads or integrated into microfluidics systems have also been considered because of their contribution to the development of compact analytical devices. The roles of these materials, the methods used for their incorporation in the biosensor configurations as well as the advantages they provide to the analyses are summarised. - Highlights: • Nanomaterials improve the performance of electrochemical biosensors. • Carbon nanomaterials can act as electrocatalysts or label supports in biosensors. • Metal nanomaterials can act as nanostructured supports or labels in biosensors. • Magnetic beads are exploited as immobilisation supports and/or label carriers.

  20. Simultaneous Determination of the Main Peanut Allergens in Foods Using Disposable Amperometric Magnetic Beads-Based Immunosensing Platforms

    Directory of Open Access Journals (Sweden)

    Víctor Ruiz-Valdepeñas Montiel

    2016-06-01

    Full Text Available In this work, a novel magnetic beads (MBs-based immunosensing approach for the rapid and simultaneous determination of the main peanut allergenic proteins (Ara h 1 and Ara h 2 is reported. It involves the use of sandwich-type immunoassays using selective capture and detector antibodies and carboxylic acid-modified magnetic beads (HOOC-MBs. Amperometric detection at −0.20 V was performed using dual screen-printed carbon electrodes (SPdCEs and the H2O2/hydroquinone (HQ system. This methodology exhibits high sensitivity and selectivity for the target proteins providing detection limits of 18.0 and 0.07 ng/mL for Ara h 1 and Ara h 2, respectively, with an assay time of only 2 h. The usefulness of the approach was evaluated by detecting the endogenous content of both allergenic proteins in different food extracts as well as trace amounts of peanut allergen (0.0001% or 1.0 mg/kg in wheat flour spiked samples. The developed platform provides better Low detection limits (LODs in shorter assay times than those claimed for the allergen specific commercial ELISA kits using the same immunoreagents and quantitative information on individual food allergen levels. Moreover, the flexibility of the methodology makes it readily translate to the detection of other food-allergens.

  1. Design and experimental validation of Unilateral Linear Halbach magnet arrays for single-sided magnetic resonance.

    Science.gov (United States)

    Bashyam, Ashvin; Li, Matthew; Cima, Michael J

    2018-07-01

    Single-sided NMR has the potential for broad utility and has found applications in healthcare, materials analysis, food quality assurance, and the oil and gas industry. These sensors require a remote, strong, uniform magnetic field to perform high sensitivity measurements. We demonstrate a new permanent magnet geometry, the Unilateral Linear Halbach, that combines design principles from "sweet-spot" and linear Halbach magnets to achieve this goal through more efficient use of magnetic flux. We perform sensitivity analysis using numerical simulations to produce a framework for Unilateral Linear Halbach design and assess tradeoffs between design parameters. Additionally, the use of hundreds of small, discrete magnets within the assembly allows for a tunable design, improved robustness to variability in magnetization strength, and increased safety during construction. Experimental validation using a prototype magnet shows close agreement with the simulated magnetic field. The Unilateral Linear Halbach magnet increases the sensitivity, portability, and versatility of single-sided NMR. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. MAGNETIC INDUCTION DISTRIBUTION IN A LINEAR SYNCHRONUS MOTOR WITH MAGNETIC SUSPENSION

    Directory of Open Access Journals (Sweden)

    D.I. Parkhomenko

    2013-02-01

    Full Text Available Results of computer simulation and experimental investigations of magnetic induction distribution in a coaxial linear synchronous motor with magnetic suspension are presented. The magnetic induction distribution has been studied both in the motor air gap and on the runner surface.

  3. ADSORPTION AND RELEASING PROPERTIES OF BEAD CELLULOSE

    Institute of Scientific and Technical Information of China (English)

    A. Morales; E. Bordallo; V. Leon; J. Rieumont

    2004-01-01

    The adsorption of some dyes on samples of bead cellulose obtained in the Unit of Research-Production "Cuba 9"was studied. Methylene blue, alizarin red and congo red fitted the adsorption isotherm of Langmuir. Adsorption kinetics at pH = 6 was linear with the square root of time indicating the diffusion is the controlling step. At pH = 12 a non-Fickian trend was observed and adsorption was higher for the first two dyes. Experiments carried out to release the methylene blue occluded in the cellulose beads gave a kinetic behavior of zero order. The study of cytochrome C adsorption was included to test a proteinic material. Crosslinking of bead cellulose was performed with epichlorohydrin decreasing its adsorption capacity in acidic or alkaline solution.

  4. Modelling a linear PM motor including magnetic saturation

    NARCIS (Netherlands)

    Polinder, H.; Slootweg, J.G.; Compter, J.C.; Hoeijmakers, M.J.

    2002-01-01

    The use of linear permanent-magnet (PM) actuators increases in a wide variety of applications because of the high force density, robustness and accuracy. The paper describes the modelling of a linear PM motor applied in, for example, wafer steppers, including magnetic saturation. This is important

  5. Beads.

    Science.gov (United States)

    Weewish Tree, 1979

    1979-01-01

    Beads served both as ornaments and as a medium of exchange, and the Indians manufactured them from such natural sources as bones, stones, beans, nuts, animal teeth, and polished antlers. Even after the introduction of European glass beads, the Indians continued to make their favorite beads from the natural sources. (DS)

  6. Repetitive Immunosensor with a Fiber-Optic Device and Antibody-Coated Magnetic Beads for Semi-Continuous Monitoring of Escherichia coli O157:H7.

    Science.gov (United States)

    Taniguchi, Midori; Saito, Hirokazu; Mitsubayashi, Kohji

    2017-09-19

    A rapid and reproducible fiber-optic immunosensor for Escherichia coli O157:H7 ( E. coli O157:H7) was described. The biosensor consisted of a flow cell, an optical fiber with a thin Ni layer, and a PC linked fluorometer. First, the samples with E. coli O157:H7 were incubated with magnetic beads coated with anti- E. coli O157:H7 antibodies and anti- E. coli O157:H7 antibodies labeled cyanine 5 (Cy5) to make sandwich complexes. Then the Cy5-( E. coli O157:H7)-beads were injected into a flow cell and pulled to the magnetized Ni layer on the optical fiber set in the flow cell. An excitation light (λ = 635 nm) was used to illuminate the optical fiber, and the Cy5 florescent molecules facing the optical fiber were exposed to an evanescent wave from the optical fiber. The 670 nm fluorescent light was measured using a photodiode. Finally, the magnetic intensity of the Ni layer was removed and the Cy5- E. coli O157:H7-beads were washed out for the next immunoassay. E. coli O157:H7, diluted with phosphate buffer (PB), was measured from 1 × 10⁵ to 1 × 10⁷ cells/mL. The total time required for an assay was less than 15 min (except for the pretreatment process) and repeating immunoassay on one optical fiber was made possible.

  7. Enzyme-linked electrochemical DNA ligation assay using magnetic beads.

    Science.gov (United States)

    Stejskalová, Eva; Horáková, Petra; Vacek, Jan; Bowater, Richard P; Fojta, Miroslav

    2014-07-01

    DNA ligases are essential enzymes in all cells and have been proposed as targets for novel antibiotics. Efficient DNA ligase activity assays are thus required for applications in biomedical research. Here we present an enzyme-linked electrochemical assay based on two terminally tagged probes forming a nicked junction upon hybridization with a template DNA. Nicked DNA bearing a 5' biotin tag is immobilized on the surface of streptavidin-coated magnetic beads, and ligated product is detected via a 3' digoxigenin tag recognized by monoclonal antibody-alkaline phosphatase conjugate. Enzymatic conversion of napht-1-yl phosphate to napht-1-ol enables sensitive detection of the voltammetric signal on a pyrolytic graphite electrode. The technique was tested under optimal conditions and various situations limiting or precluding the ligation reaction (such as DNA substrates lacking 5'-phosphate or containing a base mismatch at the nick junction, or application of incompatible cofactor), and utilized for the analysis of the nick-joining activity of a range of recombinant Escherichia coli DNA ligase constructs. The novel technique provides a fast, versatile, specific, and sensitive electrochemical assay of DNA ligase activity.

  8. Microwave synthesis of gibberellin acid 3 magnetic molecularly imprinted polymer beads for the trace analysis of gibberellin acids in plant samples by liquid chromatography-mass spectrometry detection.

    Science.gov (United States)

    Zhang, Zhuomin; Tan, Wei; Hu, Yuling; Li, Gongke; Zan, Song

    2012-02-21

    In this study, novel GA3 magnetic molecularly imprinted polymer (mag-MIP) beads were synthesized by a microwave irradiation method, and the beads were applied for the trace analysis of gibberellin acids (GAs) in plant samples including rice and cucumber coupled with high performance liquid chromatography-mass spectrometry (HPLC-MS). The microwave synthetic procedure was optimized in detail. In particular, the interaction between GA3 and functional monomers was further studied for the selection of the optimal functional monomers during synthesis. It can be seen that the interaction between GA3 and acrylamide (AM) finally selected was stronger than that between GA3 and other functional monomers. GA3 mag-MIP beads were characterized by a series of physical tests. GA3 mag-MIP beads had a porous and homogeneous surface morphology with stable chemical, thermal and magnetic properties. Moreover, GA3 mag-MIP beads demonstrated selective and specific absorption behavior for the target compounds during unsaturated extraction, which resulted in a higher extraction capacity (∼708.4 pmol for GA3) and selectivity than GA3 mag-non-imprinted polymer beads. Finally, an analytical method of GA3 mag-AM-MIP bead extraction coupled with HPLC-MS detection was established and applied for the determination of trace GA1, GA3, GA4 and GA7 in rice and cucumber samples. It was satisfactory that GA4 could be actually found to be 121.5 ± 1.4 μg kg(-1) in real rice samples by this novel analytical method. The recoveries of spiked rice and cucumber samples were found to be 76.0-109.1% and 79.9-93.6% with RSDs of 2.8-8.8% and 3.1-7.7% (n = 3), respectively. The proposed method is efficient and applicable for the trace analysis of GAs in complicated plant samples.

  9. A Rapid Detection Method of Brucella with Quantum Dots and Magnetic Beads Conjugated with Different Polyclonal Antibodies

    Science.gov (United States)

    Song, Dandan; Qu, Xiaofeng; Liu, Yushen; Li, Li; Yin, Dehui; Li, Juan; Xu, Kun; Xie, Renguo; Zhai, Yue; Zhang, Huiwen; Bao, Hao; Zhao, Chao; Wang, Juan; Song, Xiuling; Song, Wenzhi

    2017-03-01

    Brucella spp. are facultative intracellular bacteria that cause zoonotic disease of brucellosis worldwide. Traditional methods for detection of Brucella spp. take 48-72 h that does not meet the need of rapid detection. Herein, a new rapid detection method of Brucella was developed based on polyclonal antibody-conjugating quantum dots and antibody-modified magnetic beads. First, polyclonal antibodies IgG and IgY were prepared and then the antibody conjugated with quantum dots (QDs) and immunomagnetic beads (IMB), respectively, which were activated by N-(3-dimethylaminopropyl)- N'-ethylcar-bodiimide hydrochloride (EDC) and N-hydroxysuccinimide (NHS) to form probes. We used the IMB probe to separate the Brucella and labeled by the QD probe, and then detected the fluorescence intensity with a fluorescence spectrometer. The detection method takes 105 min with a limit of detection of 103 CFU/mL and ranges from 10 to 105 CFU/mL ( R 2 = 0.9983), and it can be well used in real samples.

  10. Structure and superparamagnetic behaviour of magnetite nanoparticles in cellulose beads

    Energy Technology Data Exchange (ETDEWEB)

    Correa, Jose R., E-mail: correa@fq.uh.cu [Department of General Chemistry, Faculty of Chemistry, University of Havana, Zapata and G, Havana City 10400 (Cuba); Bordallo, Eduardo [Sugar Cane-Cellulose Research Center, Cuba-9, Quivican (Cuba); Canetti, Dora [Department of Inorganic Chemistry, Faculty of Chemistry, University of Havana, Zapata and G, Havana City 10400 (Cuba); Leon, Vivian [Sugar Cane-Cellulose Research Center, Cuba-9, Quivican (Cuba); Otero-Diaz, Luis C. [Department of Inorganic Chemistry-1, Complutense University of Madrid, Madrid 28040 (Spain); Electron Microscopy Center, Complutense University of Madrid, Madrid 28040 (Spain); Negro, Carlos [Chemical Engineering Department, Complutense University of Madrid, Madrid 28040 (Spain); Gomez, Adrian [Electron Microscopy Center, Complutense University of Madrid, Madrid 28040 (Spain); Saez-Puche, Regino [Department of Inorganic Chemistry-1, Complutense University of Madrid, Madrid 28040 (Spain)

    2010-08-15

    Superparamagnetic magnetite nanoparticles were obtained starting from a mixture of iron(II) and iron(III) solutions in a preset total iron concentration from 0.04 to 0.8 mol l{sup -1} with ammonia at 25 and 70 {sup o}C. The regeneration of cellulose from viscose produces micrometrical spherical cellulose beads in which synthetic magnetite were embedded. The characterization of cellulose-magnetite beads by X-ray diffraction, Scanning and Transmission Electron Microscopy and magnetic measurement is reported. X-ray diffraction patterns indicate that the higher is the total iron concentration and temperature the higher is the crystal size of the magnetite obtained. Transmission Electron Microscopy studies of cellulose-magnetite beads revealed the distribution of magnetite nanoparticles inside pores of hundred nanometers. Magnetite as well as the cellulose-magnetite composites exhibit superparamagnetic characteristics. Field cooling and zero field cooling magnetic susceptibility measurements confirm the superparamagnetic behaviour and the blocking temperature for the magnetite with a mean size of 12.5 nm, which is 200 K.

  11. Broad-band linear polarization and magnetic intensification in rotating magnetic stars

    International Nuclear Information System (INIS)

    Degl'Innocenti, M.L.; Calamai, G.; Degl'Innocenti, E.L.; Patriarchi, P.

    1981-01-01

    Magnetic intensification is proposed as a mechanism to explain the general features of the variable broad-band linear polarization emerging from rotating magnetic stars. This mechanism is studied in detail, and some efforts are made to investigate the wide variety of polarization diagrams that can result from it. Theoretical results are compared with direct observations of the variable magnetic star 53 Cam to determine its geometric and magnetic configuration

  12. A linear magnetic motor and generator

    Science.gov (United States)

    Studer, P. A.

    1980-01-01

    In linear magnetic motor and generator suitable for remote and hostile environments, magnetic forces drive reciprocating shaft along its axis. Actuator shaft is located in center of cylindrical body and may be supported by either contacting or noncontacting bearings. When device operates as bidirectional motor, drive coil selectively adds and subtracts magnetic flux to and from flux paths, producing forces that drive actuator along axis. When actuator is driven by external reciprocating engine, device becomes ac generator.

  13. Linear magnetic motor/generator. [to generate electric energy using magnetic flux for spacecraft power supply

    Science.gov (United States)

    Studer, P. A. (Inventor)

    1982-01-01

    A linear magnetic motor/generator is disclosed which uses magnetic flux to provide mechanical motion or electrical energy. The linear magnetic motor/generator includes an axially movable actuator mechanism. A permament magnet mechanism defines a first magnetic flux path which passes through a first end portion of the actuator mechanism. Another permament magnet mechanism defines a second magnetic flux path which passes through a second end portion of the actuator mechanism. A drive coil defines a third magnetic flux path passing through a third central portion of the actuator mechanism. A drive coil selectively adds magnetic flux to and subtracts magnetic flux from magnetic flux flowing in the first and second magnetic flux path.

  14. Magnetic polymeric microspheres for protein adsorption

    International Nuclear Information System (INIS)

    Felinto, M.C.F.C.; Parra, D.F.; Lugao, A.B.; Batista, M.P.; Higa, O.Z.; Yamaura, M.; Camilo, R.L.; Ribela, M.T.C.P.; Sampaio, L.C.

    2005-01-01

    Magnetic beads consisting of polymer-coated manganese ferrite nanoparticles were prepared by the precipitation reaction of manganese ferrite into the channels of methyl methacrylate polymer beads by sodium hydroxide, resulting in MnMagBead. MnMagBead was characterized by infrared spectra (FTIR), thermogravimetric analysis of TGA/DTG and indicates the presence of -CO (carbonyl) groups and the MnFe 2 O 4 on the beads. Magnetization measurements were obtained at room temperature in magnetic fields up to 10 KOe using a vibrating sample magnetometer. Introductory Protein adsorption biological tests were processed using labeled I-125 albumin (BSA), and the activity was measured in a gamma counting spectrometer. These superparamagnetic beads exhibit the capacity to bind biological molecules such as proteins like albumin, with a good capability (5 x 10 -6 ) μg/100 mg of beads as compared with other magnetic resins studied in our group

  15. Magnetic Bead—Magic Bullet

    Directory of Open Access Journals (Sweden)

    Christine Ruffert

    2016-01-01

    Full Text Available Microfluidics is assumed to be one of the leading and most promising areas of research since the early 1990s. In microfluidic systems, small spherical magnetic particles with superparamagnetic properties, called magnetic beads, play an important role in the design of innovative methods and tools, especially in bioanalysis and medical sciences. The intention of this review paper is to address main aspects from the state-of-the-art in the area of magnetic bead research, while demonstrating the broad variety of applications and the huge potential to solve fundamental biological and medical problems in the fields of diagnostics and therapy. Basic issues and demands related to the fabrication of magnetic particles and physical properties of nanosize magnets are discussed in Section 2. Of main interest are the control and adjustment of the nanoparticles’ properties and the availability of adequate approaches for particle detection via their magnetic field. Section 3 presents an overview of magnetic bead applications in nanomedicine. In Section 4, practical aspects of sample manipulation and separation employing magnetic beads are described. Finally, the benefits related to the use of magnetic bead-based microfluidic systems are summarized, illustrating ongoing questions and open tasks to be solved on the way to an approaching microfluidic age.

  16. Switchable cell trapping using superparamagnetic beads

    Energy Technology Data Exchange (ETDEWEB)

    Bryan, M. T.; Smith, K. H.; Real, M. E.; Bashir, M. A.; Fry, P. W.; Fischer, P.; Im, M.-Y.; Schrefl, T.; Allwood, D. A.; Haycock, J. W.

    2010-04-30

    Ni{sub 81}Fe{sub 19} microwires are investigated as the basis of a switchable template for positioning magnetically-labeled neural Schwann cells. Magnetic transmission X-ray microscopy and micromagnetic modeling show that magnetic domain walls can be created or removed in zigzagged structures by an applied magnetic field. Schwann cells containing superparamagnetic beads are trapped by the field emanating from the domain walls. The design allows Schwann cells to be organized on a surface to form a connected network and then released from the surface if required. As aligned Schwann cells can guide nerve regeneration, this technique is of value for developing glial-neuronal co-culture models in the future treatment of peripheral nerve injuries.

  17. Lab-on-a-Chip Magneto-Immunoassays: How to Ensure Contact between Superparamagnetic Beads and the Sensor Surface

    Directory of Open Access Journals (Sweden)

    Andreas Hütten

    2013-09-01

    Full Text Available Lab-on-a-chip immuno assays utilizing superparamagnetic beads as labels suffer from the fact that the majority of beads pass the sensing area without contacting the sensor surface. Different solutions, employing magnetic forces, ultrasonic standing waves, or hydrodynamic effects have been found over the past decades. The first category uses magnetic forces, created by on-chip conducting lines to attract beads towards the sensor surface. Modifications of the magnetic landscape allow for additional transport and separation of different bead species. The hydrodynamic approach uses changes in the channel geometry to enhance the capture volume. In acoustofluidics, ultrasonic standing waves force µm-sized particles onto a surface through radiation forces. As these approaches have their disadvantages, a new sensor concept that circumvents these problems is suggested. This concept is based on the granular giant magnetoresistance (GMR effect that can be found in gels containing magnetic nanoparticles. The proposed design could be realized in the shape of paper-based test strips printed with gel-based GMR sensors.

  18. Bifunctional groups grafted polyethersulfone magnetic beads for selective sequestration of plutonium

    International Nuclear Information System (INIS)

    Paul, Sumana; Aggarwal, S.K.; Pandey, A.K.

    2014-01-01

    The present study involves synthesis of polyethersulfone (PES) beads grafted with two different monomers viz. 2-hydroxyethylmethacrylate phosphoric acid ester (HEMP) and 2-acrylamido-2-methyl-1-propane sulphonic acid (AMPS) by photo-induced free radical polymerization method. The selection of bifunctional polymer was based on our previous studies, which indicated its efficacy for selective preconcentration of Pu from 3-4 mol L -1 HNO 3 . The HEMP-co-AMPS grafted PES beads were used for selective extraction of plutonium from dissolver solution

  19. Superparamagnetic microbead transport induced by a magnetic field on large-area magnetic antidot arrays

    Science.gov (United States)

    Ouk, Minae; Beach, Geoffrey S. D.

    2017-12-01

    A method is presented for directed transport of superparamagnetic microbeads (SPBs) on magnetic antidot patterned substrates by applying a rotating elliptical magnetic field. We find a critical frequency for transport, beyond which the bead dynamics transitions from stepwise locomotion to local oscillation. We also find that the out-of-plane (HOOP) and in-plane (HIP) field magnitudes play crucial roles in triggering bead motion. Namely, we find threshold values in HOOP and HIP that depend on bead size, which can be used to independently and remotely address specific bead populations in a multi-bead mixture. These behaviors are explained in terms of the dynamic potential energy lansdscapes computed from micromagnetic simulations of the substrate magnetization configuration. Finally, we show that large-area magnetic patterns suitable for particle transport and sorting can be fabricated through a self-assembly lithography technique, which provides a simple, cost-effective means to integrate magnetic actuation into microfluidic systems.

  20. Enhanced quality factors and force sensitivity by attaching magnetic beads to cantilevers for atomic force microscopy in liquid

    Science.gov (United States)

    Hoof, Sebastian; Nand Gosvami, Nitya; Hoogenboom, Bart W.

    2012-12-01

    Dynamic-mode atomic force microscopy (AFM) in liquid remains complicated due to the strong viscous damping of the cantilever resonance. Here, we show that a high-quality resonance (Q >20) can be achieved in aqueous solution by attaching a microgram-bead at the end of the nanogram-cantilever. The resulting increase in cantilever mass causes the resonance frequency to drop significantly. However, the force sensitivity—as expressed via the minimum detectable force gradient—is hardly affected, because of the enhanced quality factor. Through the enhancement of the quality factor, the attached bead also reduces the relative importance of noise in the deflection detector. It can thus yield an improved signal-to-noise ratio when this detector noise is significant. We describe and analyze these effects for a set-up that includes magnetic actuation of the cantilevers and that can be easily implemented in any AFM system that is compatible with an inverted optical microscope.

  1. Viscosity of dilute suspensions of rigid bead arrays at low shear: accounting for the variation in hydrodynamic stress over the bead surfaces.

    Science.gov (United States)

    Allison, Stuart A; Pei, Hongxia

    2009-06-11

    In this work, we examine the viscosity of a dilute suspension of irregularly shaped particles at low shear. A particle is modeled as a rigid array of nonoverlapping beads of variable size and geometry. Starting from a boundary element formalism, approximate account is taken of the variation in hydrodynamic stress over the surface of the individual beads. For a touching dimer of two identical beads, the predicted viscosity is lower than the exact value by 5.2%. The methodology is then applied to several other model systems including tetramers of variable conformation and linear strings of touching beads. An analysis is also carried out of the viscosity and translational diffusion of several dilute amino acids and diglycine in water. It is concluded that continuum hydrodynamic modeling with stick boundary conditions is unable to account for the experimental viscosity and diffusion data simultaneously. A model intermediate between "stick" and "slip" could possibly reconcile theory and experiment.

  2. Strategies for enumeration of circulating microvesicles on a conventional flow cytometer: Counting beads and scatter parameters.

    Science.gov (United States)

    Alkhatatbeh, Mohammad J; Enjeti, Anoop K; Baqar, Sara; Ekinci, Elif I; Liu, Dorothy; Thorne, Rick F; Lincz, Lisa F

    2018-01-01

    Enumeration of circulating microvesicles (MVs) by conventional flow cytometry is accomplished by the addition of a known amount of counting beads and calculated from the formula: MV/μl = (MV count/bead count) × final bead concentration. We sought to optimize each variable in the equation by determining the best parameters for detecting 'MV count' and examining the effects of different bead preparations and concentrations on the final calculation. Three commercially available bead preparations (TruCount, Flow-Count and CountBright) were tested, and MV detection on a BD FACSCanto was optimized for gating by either forward scatter (FSC) or side scatter (SSC); the results were compared by calculating different subsets of MV on a series of 74 typical patient plasma samples. The relationship between the number of beads added to each test and the number of beads counted by flow cytometry remained linear over a wide range of bead concentrations ( R 2 ≥ 0.997). However, TruCount beads produced the most consistent (concentration variation = 3.8%) calculated numbers of plasma CD41 + /Annexin V + MV, which were significantly higher from that calculated using either Flow-Count or CountBright ( p beads by FSC and 0.16 μm beads by SSC, but there were significantly more background events using SSC compared with FSC (3113 vs. 470; p = 0.008). In general, sample analysis by SSC resulted in significantly higher numbers of MV ( p beads provided linear results at concentrations ranging from 6 beads/μl to 100 beads/μl, but TruCount was the most consistent. Using SSC to gate MV events produced high background which negatively affected counting bead enumeration and overall MV calculations. Strategies to reduce SSC background should be employed in order to reliably use this technique.

  3. Sequential mass spectrometric analysis of uranium and plutonium employing resin bead technique

    International Nuclear Information System (INIS)

    Ramakumar, K.L.; Aggarwal, S.K.; Chitambar, S.A.; Jain, H.C.

    1985-01-01

    Sequential mass spectrometric analysis of uranium and plutonium employing anion exchange resin bead technique is reported using a high sensitive single stage magnetic analyser instrument, the routinely employed rhenium double filament assembly and 0.5M HNO 3 as a wetting agent for loading the resin beads. A precision of bettter than 0.3per cent (2sigma) is obtained on the isotopic ratio measurements. However, extreme care has to be exercised to carry the resin bead experiments under ultra clean conditions so as to avoid pick up of contamination. (author)

  4. Linearized models for a new magnetic control in MAST

    International Nuclear Information System (INIS)

    Artaserse, G.; Maviglia, F.; Albanese, R.; McArdle, G.J.; Pangione, L.

    2013-01-01

    Highlights: ► We applied linearized models for a new magnetic control on MAST tokamak. ► A suite of procedures, conceived to be machine independent, have been used. ► We carried out model-based simulations, taking into account eddy currents effects. ► Comparison with the EFIT flux maps and the experimental magnetic signals are shown. ► A current driven model for the dynamic simulations of the experimental data have been performed. -- Abstract: The aim of this work is to provide reliable linearized models for the design and assessment of a new magnetic control system for MAST (Mega Ampère Spherical Tokamak) using rtEFIT, which can easily be exported to MAST Upgrade. Linearized models for magnetic control have been obtained using the 2D axisymmetric finite element code CREATE L. MAST linearized models include equivalent 2D axisymmetric schematization of poloidal field (PF) coils, vacuum vessel, and other conducting structures. A plasmaless and a double null configuration have been chosen as benchmark cases for the comparison with experimental data and EFIT reconstructions. Good agreement has been found with the EFIT flux map and the experimental signals coming from magnetic probes with only few mismatches probably due to broken sensors. A suite of procedures (equipped with a user friendly interface to be run even remotely) to provide linearized models for magnetic control is now available on the MAST linux machines. A new current driven model has been used to obtain a state space model having the PF coil currents as inputs. Dynamic simulations of experimental data have been carried out using linearized models, including modelling of the effects of the passive structures, showing a fair agreement. The modelling activity has been useful also to reproduce accurately the interaction between plasma current and radial position control loops

  5. Linearized models for a new magnetic control in MAST

    Energy Technology Data Exchange (ETDEWEB)

    Artaserse, G., E-mail: giovanni.artaserse@enea.it [Associazione Euratom-ENEA sulla Fusione, Via Enrico Fermi 45, I-00044 Frascati (RM) (Italy); Maviglia, F.; Albanese, R. [Associazione Euratom-ENEA-CREATE sulla Fusione, Via Claudio 21, I-80125 Napoli (Italy); McArdle, G.J.; Pangione, L. [EURATOM/CCFE Fusion Association, Culham Science Centre, Abingdon, Oxon, OX14 3DB (United Kingdom)

    2013-10-15

    Highlights: ► We applied linearized models for a new magnetic control on MAST tokamak. ► A suite of procedures, conceived to be machine independent, have been used. ► We carried out model-based simulations, taking into account eddy currents effects. ► Comparison with the EFIT flux maps and the experimental magnetic signals are shown. ► A current driven model for the dynamic simulations of the experimental data have been performed. -- Abstract: The aim of this work is to provide reliable linearized models for the design and assessment of a new magnetic control system for MAST (Mega Ampère Spherical Tokamak) using rtEFIT, which can easily be exported to MAST Upgrade. Linearized models for magnetic control have been obtained using the 2D axisymmetric finite element code CREATE L. MAST linearized models include equivalent 2D axisymmetric schematization of poloidal field (PF) coils, vacuum vessel, and other conducting structures. A plasmaless and a double null configuration have been chosen as benchmark cases for the comparison with experimental data and EFIT reconstructions. Good agreement has been found with the EFIT flux map and the experimental signals coming from magnetic probes with only few mismatches probably due to broken sensors. A suite of procedures (equipped with a user friendly interface to be run even remotely) to provide linearized models for magnetic control is now available on the MAST linux machines. A new current driven model has been used to obtain a state space model having the PF coil currents as inputs. Dynamic simulations of experimental data have been carried out using linearized models, including modelling of the effects of the passive structures, showing a fair agreement. The modelling activity has been useful also to reproduce accurately the interaction between plasma current and radial position control loops.

  6. A magnetic method to concentrate and trap biological targets

    KAUST Repository

    Li, Fuquan

    2012-11-01

    Magnetoresistive sensors in combination with magnetic particles have been used in biological applications due to, e.g., their small size and high sensitivity. A growing interest is to integrate magnetoresistive sensors with microchannels and electronics to fabricate devices that can perform complex analyses. A major task in such systems is to immobilize magnetic particles on top of the sensor surface, which is required to detect the particles\\' stray field. In the presented work, a bead concentrator, consisting of gold microstructures, at the bottom of a microchannel, is used to attract and move magnetic particles into a trap. The trap is made of a chamber with a gold microstructure underneath and is used to attract and immobilize a defined number of magnetic beads. In order to detect targets, two kinds of solutions were prepared; one containing only superparamagnetic particles, the other one containing beads with the protein Bovine serum albumin as the target and fluorescent markers. Due to the size difference between bare beads and beads with target, less magnetic beads were immobilized inside the volume chamber in case of magnetic beads with target as compared to bare magnetic beads. © 1965-2012 IEEE.

  7. Fluorescent detection of C-reactive protein using polyamide beads

    Science.gov (United States)

    Jagadeesh, Shreesha; Chen, Lu; Aitchison, Stewart

    2016-03-01

    Bacterial infection causes Sepsis which is one of the leading cause of mortality in hospitals. This infection can be quantified from blood plasma using C - reactive protein (CRP). A quick diagnosis at the patient's location through Point-of- Care (POC) testing could give doctors the confidence to prescribe antibiotics. In this paper, the development and testing of a bead-based procedure for CRP quantification is described. The size of the beads enable them to be trapped in wells without the need for magnetic methods of immobilization. Large (1.5 mm diameter) Polyamide nylon beads were used as the substrate for capturing CRP from pure analyte samples. The beads captured CRP either directly through adsorption or indirectly by having specific capture antibodies on their surface. Both methods used fluorescent imaging techniques to quantify the protein. The amount of CRP needed to give a sufficient fluorescent signal through direct capture method was found suitable for identifying bacterial causes of infection. Similarly, viral infections could be quantified by the more sensitive indirect capture method. This bead-based assay can be potentially integrated as a disposable cartridge in a POC device due to its passive nature and the small quantities needed.

  8. Magnetic levitation configuration incorporating levitation, guidance and linear synchronous motor

    Science.gov (United States)

    Coffey, Howard T.

    1993-01-01

    A propulsion and suspension system for an inductive repulsion type magnetically levitated vehicle which is propelled and suspended by a system which includes propulsion windings which form a linear synchronous motor and conductive guideways, adjacent to the propulsion windings, where both combine to partially encircling the vehicle-borne superconducting magnets. A three phase power source is used with the linear synchronous motor to produce a traveling magnetic wave which in conjunction with the magnets propel the vehicle. The conductive guideway combines with the superconducting magnets to provide for vehicle leviation.

  9. Magnetic levitation configuration incorporating levitation, guidance and linear synchronous motor

    Science.gov (United States)

    Coffey, H.T.

    1993-10-19

    A propulsion and suspension system for an inductive repulsion type magnetically levitated vehicle which is propelled and suspended by a system which includes propulsion windings which form a linear synchronous motor and conductive guideways, adjacent to the propulsion windings, where both combine to partially encircling the vehicle-borne superconducting magnets. A three phase power source is used with the linear synchronous motor to produce a traveling magnetic wave which in conjunction with the magnets propel the vehicle. The conductive guideway combines with the superconducting magnets to provide for vehicle levitation. 3 figures.

  10. Magnetic biosensor system to detect biological targets

    KAUST Repository

    Li, Fuquan; Gooneratne, Chinthaka Pasan; Kosel, Jü rgen

    2012-01-01

    magnetic concentration, magnetic as well as mechanical trapping and magnetic sensing. Target detection is based on the size difference between bare magnetic beads and magnetic beads with targets attached. This method remedies the need for a coating layer

  11. A giant magnetoresistance ring-sensor based microsystem for magnetic bead manipulation and detection

    KAUST Repository

    Gooneratne, Chinthaka P.

    2011-03-28

    In this paper a novel spin valvegiant magnetoresistance(GMR) ring-sensor integrated with a microstructure is proposed for concentrating, trapping, and detecting superparamagnetic beads (SPBs). Taking advantage of the fact that SPBs can be manipulated by an external magnetic field, a unique arrangement of conducting microrings is utilized to manipulate the SPBs toward the GMR sensing area in order to increase the reliability of detection. The microrings are arranged and activated in such a manner so as to enable the detection of minute concentrations of SPBs in a sample. Precise manipulation is achieved by applying current sequentially to the microrings. The fabricated ring-shaped GMR element is located underneath the innermost ring and has a magnetoresistance of approximately 5.9%. By the performed experiments it was shown that SPBs could be successfully manipulated toward the GMR sensing zone.

  12. A giant magnetoresistance ring-sensor based microsystem for magnetic bead manipulation and detection

    KAUST Repository

    Gooneratne, Chinthaka P.; Giouroudi, Ioanna; Liang, Cai; Kosel, Jü rgen

    2011-01-01

    In this paper a novel spin valvegiant magnetoresistance(GMR) ring-sensor integrated with a microstructure is proposed for concentrating, trapping, and detecting superparamagnetic beads (SPBs). Taking advantage of the fact that SPBs can be manipulated by an external magnetic field, a unique arrangement of conducting microrings is utilized to manipulate the SPBs toward the GMR sensing area in order to increase the reliability of detection. The microrings are arranged and activated in such a manner so as to enable the detection of minute concentrations of SPBs in a sample. Precise manipulation is achieved by applying current sequentially to the microrings. The fabricated ring-shaped GMR element is located underneath the innermost ring and has a magnetoresistance of approximately 5.9%. By the performed experiments it was shown that SPBs could be successfully manipulated toward the GMR sensing zone.

  13. Early Diagnosis of Irkut Virus Infection Using Magnetic Bead-Based Serum Peptide Profiling by MALDI-TOF MS in a Mouse Model

    Directory of Open Access Journals (Sweden)

    Nan Li

    2014-03-01

    Full Text Available Early diagnosis is important for the prompt post-exposure prophylaxis of lyssavirus infections. To diagnose Irkut virus (IRKV infection during incubation in mice, a novel method using magnetic bead-based serum peptide profiling by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS has been established. For this test, serum peptides were concentrated by adsorption to and elution from the magnetic bead-based weak cation ion exchanger. Mass spectrograms obtained by MALDI-TOF MS were analyzed using ClinProTools bioinformatics software. Construction of the diagnostic model was performed using serum samples from mice infected with IRKV and rabies virus (RABV BD06, Flury-LEP, and SRV9 (as controls. The method accurately diagnosed sera 2, 4 and 8 days after IRKV and RABV infections. The sensitivity, specificity, and total accuracy of diagnosis were 86.7%, 95.2%, and 92.9%, respectively. However, IRKV could not be differentiated from RABV 1 day after infection. The results of the present study indicate that serum peptide profiling by MALDI-TOF MS is a promising technique for the early clinical diagnosis of lyssavirus infections and needs to be further tested in humans and farm animals.

  14. Acetylcholinesterase immobilized capillary reactors coupled to protein coated magnetic beads: A new tool for plant extract ligand screening

    OpenAIRE

    Vanzolini, Kenia Lourenço; Jiang, Zhengjin; Zhang, Xiaoqi; Vieira, Lucas Campos Curcino; Corrêa, Arlene Gonçalvez; Cardoso, Carmen Lucia; Cass, Quezia Bezerra; Moaddel, Ruin

    2013-01-01

    The use of immobilized capillary enzyme reactors (ICERs) and enzymes coated to magnetic beads ((NT or CT)-MB) for ligand screening has been adopted as a new technique of high throughput screening (HTS). In this work the selected target was the enzyme acetylcholinesterase (AChE), which acts on the central nervous system and is a validated target for the treatment of Alzheimer’s disease, as well as for new insecticides. A new approach for the screening of plant extracts was developed based on t...

  15. Novel ocean energy permanent magnet linear generator buoy

    Energy Technology Data Exchange (ETDEWEB)

    Rhinefrank, K.; Agamloh, E.B.; Jouanne, A. von; Wallace, A.K.; Prudell, J.; Kimble, K.; Aills, J.; Schmidt, E.; Schacher, A. [School of Electrical Engineering and Computer Science, Oregon State University, Corvallis, OR 97331-3211 (United States); Chan, P.; Sweeny, B. [Department of Mechanical Engineering, Oregon State University, Corvallis, OR 97331-3211 (United States)

    2006-07-15

    This paper describes the research, design, construction and prototype testing process of a novel ocean energy direct drive permanent magnet linear generator buoy. The buoy employs the vertical component of the motion of ocean waves to power a linear generator. The generator consists of a permanent magnet field system (mounted on the central translator shaft) and an armature, in which the power is generated (mounted on the buoy). The translator shaft is anchored to the sea floor, and the buoy/floater moves armature coils relative to the permanent magnet translator to induce voltages. The electrical and mechanical structures of the buoy generator are provided, along with performance characteristics, including voltage, current and developed power. (author)

  16. A Mössbauer study of the chemical stability of iron oxide nanoparticles in PMMA and PVB beads

    DEFF Research Database (Denmark)

    Chen, Wei; Mørup, Steen; Hansen, Mikkel Fougt

    2008-01-01

    We have prepared magnetic beads consisting of iron oxide nanoparticles in a polymethyl methacrylate (PMMA) and a polyvinyl butyral (PVB) matrix. High-field Mossbauer studies show that the particles have an almost perfect collinear spin structure and magnetization measurements show that they are s...... transformed to maghemite. The PVB beads are hydrophilic and biocompatible and are therefore well suited for applications in medicine and biology....

  17. Low-cost commercial glass beads as dosimeters in radiotherapy

    International Nuclear Information System (INIS)

    Jafari, S.M.; Bradley, D.A.; Gouldstone, C.A.; Sharpe, P.H.G.; Alalawi, A.; Jordan, T.J.; Clark, C.H.; Nisbet, A.; Spyrou, N.M.

    2014-01-01

    Recent developments in advanced radiotherapy techniques using small field photon beams, require small detectors to determine the delivered dose in steep dose gradient fields. Commercially available glass jewellery beads exhibit thermoluminescent properties and have the potential to be used as dosimeters in radiotherapy due to their small size ( 60 Co gamma rays over doses ranging from 1 to 2500 cGy. A thermoluminescence (TL) system and an electron paramagnetic resonance (EPR) system were employed for read out. Both the TL and EPR studies demonstrated a radiation-induced signal, the sensitivity of which varied with bead colour. White coloured beads proved to be the most sensitive for both systems. The smallest and therefore least sensitive bead sizes allowed measurement of doses of 1 cGy using the TL system while that for the EPR system was approximately 1000 cGy. The fading rate was found to be 10% 30 days after irradiation with both readout systems. The dose response is linear with measured dose over the dose range 1 to 2500 cGy, with an R 2 correlation coefficient of greater than 0.999. The batch-to-batch reproducibility of a set of dosimeters after a single irradiation was found to be 3% (1 SD). The reproducibility of individual dosimeters was found to be 1.7%. No measurable angular dependence was found (results agreed within 1%). Dose rate response was found to agree within 1% for dose rates of 100 to 600 cGy/min. These results demonstrate the potential use of glass beads as TL dosimeters over the dose range commonly applied in radiotherapy. - Highlights: • We examined the dosimetric properties of a low cost commercially produced glass seed beads. • Glass beads are available in small size of 1–3 mm, suitable for dosimetry of small radiation fields. • The results demonstrate a mean reproducibility of 0.23% (2 SD), batch homogeneity of within 5%. • Dose response was linear over wide dose range tested for 1 cGy to kGy. • Improved fading effect of 10

  18. Magnetic biosensor system to detect biological targets

    KAUST Repository

    Li, Fuquan

    2012-09-01

    Magneto-resistive sensors in combination with magnetic beads provide sensing platforms, which are small in size and highly sensitive. These platforms can be fully integrated with microchannels and electronics to enable devices capable of performing complex tasks. Commonly, a sandwich method is used that requires a specific coating of the sensor\\'s surface to immobilize magnetic beads and biological targets on top of the sensor. This paper concerns a micro device to detect biological targets using magnetic concentration, magnetic as well as mechanical trapping and magnetic sensing. Target detection is based on the size difference between bare magnetic beads and magnetic beads with targets attached. This method remedies the need for a coating layer and reduces the number of steps required to run an experiment. © 2012 IEEE.

  19. [Detection of serum proteins in the patients of lung adenocarcinoma by the method of magnetic bead based sample fractionation and MALDI-TOF-MS].

    Science.gov (United States)

    Liu, Dan; Liu, Lun-Xu; Yuan, Quan; Li, Xiao-Liang; Huang, Na; Yang, Xiao-Dong

    2010-05-01

    To screen the serum proteins related to human lung adenocarcinoma using matrix-assisted laser desorption/ionization time of flight mass spectrometry (MALDI-TOF-MS) technology. The blood samples were collected from 10 patients of lung adenocarcinoma before and one week after the surgery, while 10 healthy subjects were used as control. The differential protein expression between the two groups and the change of those proteins after surgery were studied by ClinProt magnetic bead enrichment and MALDI-TOF-MS. Six protein peaks were identified, 2 of them were highly expressed protein biomarkers with relative molecular weights of 2661, 2991, and increased after the surgery, 4 of them were lowly expressed protein biomarkers with relative molecular weights of 4091, 4210, 4644, 5336, which continuously decreased after the surgery. ClinProt magnetic bead enrichment and MALDI-TOF-MS is a quick, easy and sensitive method of proteomics. The differential expressed proteins may be the latent tumor marker of lung adenocarcinoma. The alteration of those proteins after surgery might be helpful to assess the therapeutic effect and prognosis.

  20. Development of an immunomagnetic bead-based time-resolved fluorescence immunoassay for rapid determination of levels of carcinoembryonic antigen in human serum

    Energy Technology Data Exchange (ETDEWEB)

    Hou Jingyuan; Liu Tiancai; Lin Guanfeng; Li Zhixiong; Zou Liping; Li Ming [Institute of Antibody Engineering, School of Biotechnology, Southern Medical University, Guangzhou 510515 (China); Wu Yingsong, E-mail: wg@fimmu.com [Institute of Antibody Engineering, School of Biotechnology, Southern Medical University, Guangzhou 510515 (China)

    2012-07-13

    Highlights: Black-Right-Pointing-Pointer Magnetic beads was used as the solid phase for TRFIA. Black-Right-Pointing-Pointer The linearity range was broadened greatly compared with conventional TRFIA method. Black-Right-Pointing-Pointer The analysis time was significantly shorter compared with conventional TRFIA method. Black-Right-Pointing-Pointer This method could be developed for practical clinical detections of tumor-associated antigens. - Abstract: A novel immunoassay for the determination of tumor markers in human serum was established by combining a time-resolved fluoroimmunoassay (TRFIA) and immunomagnetic separation. Based on a sandwich-type immunoassay format, analytes in samples were captured by magnetic beads coated with one monoclonal antibody and 'sandwiched' by another monoclonal antibody labeled with europium chelates. The immunocomplex was separated and washed by exposure to a magnetic field and treatment with enhancement solution; fluorescence was then measured according to the number of europium ions dissociated. Levels of the model analyte, carcinoembryonic antigen (CEA), were determined in a linear range (1-1000 ng mL{sup -1}) with a limit of detection of 0.5 ng mL{sup -1} under optimal conditions. The reproducibility, recovery, and specificity of the immunoassay were demonstrated to be acceptable. To evaluate this novel assay for clinical applications, 239 serum samples were evaluated. Compared with the conventional TRFIA and chemiluminescence immunoassay (CLIA), the correlation coefficients of the developed immunoassay were 0.985 and 0.975, respectively. These results showed good correlation and confirmed that our method is feasible and could be used for the clinical determination of CEA (or other tumor antigens) in human serum.

  1. Linear optical response of carbon nanotubes under axial magnetic field

    Science.gov (United States)

    Moradian, Rostam; Chegel, Raad; Behzad, Somayeh

    2010-04-01

    We considered single walled carbon naotubes (SWCNTs) as real three dimensional (3D) systems in a cylindrical coordinate. The optical matrix elements and linear susceptibility, χ(ω), in the tight binding approximation in terms of one-dimensional wave vector, kz and subband index, l are calculated. In an external axial magnetic field optical frequency dependence of linear susceptibility are investigated. We found that axial magnetic field has two effects on the imaginary part of the linear susceptibility spectrum, in agreement with experimental results. The first effect is broadening and the second, splitting. Also we found that for all metallic zigzag and armchair SWCNTs, the axial magnetic field leads to the creation of a peak with energy less than 1.5 eV, contrary to what is observed in the absence of a magnetic field.

  2. An ultrasensitive chemiluminescence immunoassay of chloramphenicol based on gold nanoparticles and magnetic beads.

    Science.gov (United States)

    Tao, Xiaoqi; Jiang, Haiyang; Yu, Xuezhi; Zhu, Jinghui; Wang, Xia; Wang, Zhanhui; Niu, Lanlan; Wu, Xiaoping; Shen, Jianzhong

    2013-05-01

    A competitive, direct, chemiluminescent immunoassay based on a magnetic beads (MBs) separation and gold nanoparticles (AuNPs) labelling technique to detect chloramphenicol (CAP) has been developed. Horseradish peroxidase (HRP)-labelled anti-CAP monoclonal antibody conjugated with AuNPs and antigen-immobilized MBs were prepared. After optimization parameters of immunocomplex MBs, the IC50 values of chemiluminescence magnetic nanoparticles immunoassay (CL-MBs-nano-immunoassay) were 0.017 µg L(-1) for extract method I and 0.17 µg L(-1) for extract method II. The immunoassay with two extract methods was applied to detect CAP in milk. Comparison of these two extract methods showed that extract method I was advantageous in better sensitivity, in which the sensitivity was 10 times compared to that of extract method II, while extract method II was superior in simple operation, suitable for high throughout screen. The recoveries were 86.7-98.0% (extract method I) and 80.0-103.0% (extract method II), and the coefficients of variation (CVs) were all recovery with both extract methods and high correlation with traditional ELISA kit in milk system confirmed that the immunomagnetic assay based on AuNPs exhibited promising potential in rapid field screening for trace CAP analysis. Copyright © 2013 John Wiley & Sons, Ltd.

  3. Magnetic Flux Distribution of Linear Machines with Novel Three-Dimensional Hybrid Magnet Arrays

    Directory of Open Access Journals (Sweden)

    Nan Yao

    2017-11-01

    Full Text Available The objective of this paper is to propose a novel tubular linear machine with hybrid permanent magnet arrays and multiple movers, which could be employed for either actuation or sensing technology. The hybrid magnet array produces flux distribution on both sides of windings, and thus helps to increase the signal strength in the windings. The multiple movers are important for airspace technology, because they can improve the system’s redundancy and reliability. The proposed design concept is presented, and the governing equations are obtained based on source free property and Maxwell equations. The magnetic field distribution in the linear machine is thus analytically formulated by using Bessel functions and harmonic expansion of magnetization vector. Numerical simulation is then conducted to validate the analytical solutions of the magnetic flux field. It is proved that the analytical model agrees with the numerical results well. Therefore, it can be utilized for the formulation of signal or force output subsequently, depending on its particular implementation.

  4. Establishing a novel automated magnetic bead-based method for the extraction of DNA from a variety of forensic samples.

    Science.gov (United States)

    Witt, Sebastian; Neumann, Jan; Zierdt, Holger; Gébel, Gabriella; Röscheisen, Christiane

    2012-09-01

    Automated systems have been increasingly utilized for DNA extraction by many forensic laboratories to handle growing numbers of forensic casework samples while minimizing the risk of human errors and assuring high reproducibility. The step towards automation however is not easy: The automated extraction method has to be very versatile to reliably prepare high yields of pure genomic DNA from a broad variety of sample types on different carrier materials. To prevent possible cross-contamination of samples or the loss of DNA, the components of the kit have to be designed in a way that allows for the automated handling of the samples with no manual intervention necessary. DNA extraction using paramagnetic particles coated with a DNA-binding surface is predestined for an automated approach. For this study, we tested different DNA extraction kits using DNA-binding paramagnetic particles with regard to DNA yield and handling by a Freedom EVO(®)150 extraction robot (Tecan) equipped with a Te-MagS magnetic separator. Among others, the extraction kits tested were the ChargeSwitch(®)Forensic DNA Purification Kit (Invitrogen), the PrepFiler™Automated Forensic DNA Extraction Kit (Applied Biosystems) and NucleoMag™96 Trace (Macherey-Nagel). After an extensive test phase, we established a novel magnetic bead extraction method based upon the NucleoMag™ extraction kit (Macherey-Nagel). The new method is readily automatable and produces high yields of DNA from different sample types (blood, saliva, sperm, contact stains) on various substrates (filter paper, swabs, cigarette butts) with no evidence of a loss of magnetic beads or sample cross-contamination. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  5. Synthesis and applications of magnetic nanoparticles for biorecognition and point of care medical diagnostics

    International Nuclear Information System (INIS)

    Sandhu, Adarsh; Handa, Hiroshi; Abe, Masanori

    2010-01-01

    ' by nanometer sized 'target beads', enabling the detection of small concentrations of beads as small as 8 nm in 'pumpless' microcapillary systems. Finally, we describe a 'label-less homogeneous' procedure referred to as 'magneto-optical transmission (MT) sensing', where the optical transmission of a solution containing rotating linear chains of magnetic nanobeads was used to detect biomolecules with pM-level sensitivity with a dynamic range of more than four orders of magnitude. Our research on the synthesis and applications of nanoparticles is particularly suitable for point of care diagnostics. (topical review)

  6. Self-assembled magnetic filter for highly efficient immunomagnetic separation.

    Science.gov (United States)

    Issadore, David; Shao, Huilin; Chung, Jaehoon; Newton, Andita; Pittet, Mikael; Weissleder, Ralph; Lee, Hakho

    2011-01-07

    We have developed a compact and inexpensive microfluidic chip, the self-assembled magnetic filter, to efficiently remove magnetically tagged cells from suspension. The self-assembled magnetic filter consists of a microfluidic channel built directly above a self-assembled NdFeB magnet. Micrometre-sized grains of NdFeB assemble to form alternating magnetic dipoles, creating a magnetic field with a very strong magnitude B (from the material) and field gradient ▽B (from the configuration) in the microfluidic channel. The magnetic force imparted on magnetic beads is measured to be comparable to state-of-the-art microfabricated magnets, allowing for efficient separations to be performed in a compact, simple device. The efficiency of the magnetic filter is characterized by sorting non-magnetic (polystyrene) beads from magnetic beads (iron oxide). The filter enriches the population of non-magnetic beads to magnetic beads by a factor of >10(5) with a recovery rate of 90% at 1 mL h(-1). The utility of the magnetic filter is demonstrated with a microfluidic device that sorts tumor cells from leukocytes using negative immunomagnetic selection, and concentrates the tumor cells on an integrated membrane filter for optical detection.

  7. Preparation of magnetic nanoparticles embedded in polystyrene microspheres

    International Nuclear Information System (INIS)

    Nguyen Hoang Hai; Nguyen Hoang Luong; Nguyen Chau; Ngo Quy Tai

    2009-01-01

    Superparamagnetic particles are widely used for biological applications such as cell separation. The size of the particles is normally in the range of 10 - 20 nm which is much smaller than the size of a cell. Therefore small particles create small force which is not strong enough to separate the cells from solution. Superparamagnetic nanoparticles embedded in Polystyrene microspheres (magnetic beads) are very useful for cell separation. Magnetic beads have been prepared by solvent evaporation of an emulsion. The beads with size of 0.2 μm - 1.0 μm have a saturation magnetization of 10 - 25 emu/g. The change of the amount of surfactants, volatile solvent, magnetic particles resulted to the change of size, magnetic properties of the magnetic beads.

  8. Adsorption of ochratoxin A from grape juice by yeast cells immobilised in calcium alginate beads.

    Science.gov (United States)

    Farbo, Maria Grazia; Urgeghe, Pietro Paolo; Fiori, Stefano; Marceddu, Salvatore; Jaoua, Samir; Migheli, Quirico

    2016-01-18

    Grape juice can be easily contaminated with ochratoxin A (OTA), one of the known mycotoxins with the greatest public health significance. Among the different approaches to decontaminate juice from this mycotoxin, microbiological methods proved efficient, inexpensive and safe, particularly the use of yeast or yeast products. To ascertain whether immobilisation of the yeast biomass would lead to successful decontamination, alginate beads encapsulating Candida intermedia yeast cells were used in our experiments to evaluate their OTA-biosorption efficacy. Magnetic calcium alginate beads were also prepared by adding magnetite in the formulation to allow fast removal from the aqueous solution with a magnet. Calcium alginate beads were added to commercial grape juice spiked with 20 μg/kg OTA and after 48 h of incubation a significant reduction (>80%), of the total OTA content was achieved, while in the subsequent phases (72-120 h) OTA was slowly released into the grape juice by alginate beads. Biosorption properties of alginate-yeast beads were tested in a prototype bioreactor consisting in a glass chromatography column packed with beads, where juice amended with OTA was slowly flowed downstream. The adoption of an interconnected scaled-up bioreactor as an efficient and safe tool to remove traces of OTA from liquid matrices is discussed. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Non-linear spin transport in magnetic semiconductor superlattices

    International Nuclear Information System (INIS)

    Bejar, Manuel; Sanchez, David; Platero, Gloria; MacDonald, A.H.

    2004-01-01

    The electronic spin dynamics in DC-biased n-doped II-VI semiconductor multiquantum wells doped with magnetic impurities is presented. Under certain range of electronic doping, conventional semiconductor superlattices present self-sustained oscillations. Magnetically doped wells (Mn) present large spin splittings due to the exchange interaction. The interplay between non-linear interwell transport, the electron-electron interaction and the exchange between electrons and the magnetic impurities produces interesting time-dependent features in the spin polarization current tuned by an external magnetic field

  10. Estimation of non-linear effective permeability of magnetic materials with fine structure

    International Nuclear Information System (INIS)

    Waki, H.; Igarashi, H.; Honma, T.

    2006-01-01

    This paper describes a homogenization method for magnetic materials with fine structure. In this method, the structures of the magnetic materials are assumed to be periodic, and the unit cell is defined. The effective permeability is determined on the basis of magnetic energy balance in the unit cell. This method can be applied not only for linear problems but also for non-linear ones. In this paper, estimation of the effective permeability of non-linear magnetic materials by using the homogenization method is described in detail, and then the validity for the non-liner problems is tested for two-dimensional problems. It is shown that this homogenization method gives accurate non-linear effective permeability

  11. Measurements of Rayleigh-Taylor-Induced Magnetic Fields in the Linear and Non-linear Regimes

    Science.gov (United States)

    Manuel, Mario

    2012-10-01

    Magnetic fields are generated in plasmas by the Biermann-battery, or thermoelectric, source driven by non-collinear temperature and density gradients. The ablation front in laser-irradiated targets is susceptible to Rayleigh-Taylor (RT) growth that produces gradients capable of generating magnetic fields. Measurements of these RT-induced magnetic fields in planar foils have been made using a combination of x-ray and monoenergetic-proton radiography techniques. At a perturbation wavelength of 120 μm, proton radiographs indicate an increase of the magnetic-field strength from ˜1 to ˜10 Tesla during the linear growth phase. A characteristic change in field structure was observed later in time for irradiated foils of different initial surface perturbations. Proton radiographs show a regular cellular configuration initiated at the same time during the drive, independent of the initial foil conditions. This non-linear behavior has been experimentally investigated and the source of these characteristic features will be discussed.

  12. Design, analysis and fabrication of a linear permanent magnet ...

    Indian Academy of Sciences (India)

    MONOJIT SEAL

    Linear permanent magnet synchronous machine; LPMSM—fabrication; design optimisation; finite-element ... induction motor (LIM) prototype was patented in 1890 [1]. Since then, linear ..... Also, for manual winding, more slot area is allotted to ...

  13. Proteomic profiling of renal allograft rejection in serum using magnetic bead-based sample fractionation and MALDI-TOF MS.

    Science.gov (United States)

    Sui, Weiguo; Huang, Liling; Dai, Yong; Chen, Jiejing; Yan, Qiang; Huang, He

    2010-12-01

    Proteomics is one of the emerging techniques for biomarker discovery. Biomarkers can be used for early noninvasive diagnosis and prognosis of diseases and treatment efficacy evaluation. In the present study, the well-established research systems of ClinProt Micro solution incorporated unique magnetic bead sample preparation technology, which, based on matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS), have become very successful in bioinformatics due to its outstanding performance and reproducibility for discovery disease-related biomarker. We collected fasting blood samples from patients with biopsy-confirmed acute renal allograft rejection (n = 12), chronic rejection (n = 12), stable graft function (n = 12) and also from healthy volunteers (n = 13) to study serum peptidome patterns. Specimens were purified with magnetic bead-based weak cation exchange chromatography and analyzed with a MALDI-TOF mass spectrometer. The results indicated that 18 differential peptide peaks were selected as potential biomarkers of acute renal allograft rejection, and 6 differential peptide peaks were selected as potential biomarkers of chronic rejection. A Quick Classifier Algorithm was used to set up the classification models for acute and chronic renal allograft rejection. The algorithm models recognize 82.64% of acute rejection and 98.96% of chronic rejection episodes, respectively. We were able to identify serum protein fingerprints in small sample sizes of recipients with renal allograft rejection and establish the models for diagnosis of renal allograft rejection. This preliminary study demonstrated that proteomics is an emerging tool for early diagnosis of renal allograft rejection and helps us to better understand the pathogenesis of disease process.

  14. Enzymatic removal of phenol and p-chlorophenol in enzyme reactor: Horseradish peroxidase immobilized on magnetic beads

    International Nuclear Information System (INIS)

    Bayramoglu, Guelay; Arica, M. Yakup

    2008-01-01

    Horseradish peroxidase was immobilized on the magnetic poly(glycidylmethacrylate-co-methylmethacrylate) (poly(GMA-MMA)), via covalent bonding and used for the treatment of phenolic wastewater in continuous systems. For this purposes, horseradish peroxidase (HRP) was covalently immobilized onto magnetic poly(GMA-MMA) beds using glutaraldehyde (GA) as a coupling agent. The maximum HRP immobilization capacity of the magnetic poly(GMA-MMA)-GA beads was 3.35 mg g -1 . The immobilized HRP retained 79% of the activity of the free HRP used for immobilization. The immobilized HRP was used for the removal of phenol and p-chlorophenol via polymerization of dissolved phenols in the presence of hydrogen peroxide (H 2 O 2 ). The effect of pH and temperature on the phenol oxidation rate was investigated. The results were compared with the free HRP, which showed that the optimum pH value for the immobilized HRP is similar to that for the free HRP. The optimum pH value for free and immobilized HRP was observed at pH 7.0. The optimum temperature for phenols oxidation with immobilized HRP was between 25 and 35 deg. C and the immobilized HRP has more resistance to temperature inactivation than that of the free form. Finally, the immobilized HRP was operated in a magnetically stabilized fluidized bed reactor, and phenols were successfully removed in the enzyme reactor

  15. Linear and nonlinear electrostatic modes in a nonuniform magnetized electron plasma

    International Nuclear Information System (INIS)

    Vranjes, J.; Shukla, P.K.; Kono, M.; Poedts, S.

    2001-01-01

    Linear and nonlinear low-frequency modes in a magnetized electron plasma are studied, taking into account a proper description of the equilibrium plasma state that is inhomogeneous. Assuming a homogeneous magnetic field and sheared plasma flows, flute-like perturbations are studied in the presence of density and potential gradients. Linear analysis reveals the presence of a streaming instability and depicts conditions for global linear spiral mode. In the nonlinear domain, a tripolar vortex, which is driven and carried by the flow, is found. Also investigated are the consequences of a magnetic shear as well as nonuniformities along the magnetic field lines, which are shown to be responsible for the possible annulment of the magnetic shear effects. Streaming along the lines of the sheared magnetic field is also studied. A variety of nonlinear structures (viz. global multipolar vortices, local vortex chains, and tripolar vortices) is shown to be the consequence of the simultaneous action of the parallel and perpendicular flows

  16. Modeling of non-ideal hard permanent magnets with an affine-linear model, illustrated for a bar and a horseshoe magnet

    Science.gov (United States)

    Glane, Sebastian; Reich, Felix A.; Müller, Wolfgang H.

    2017-11-01

    This study is dedicated to continuum-scale material modeling of isotropic permanent magnets. An affine-linear extension to the commonly used ideal hard model for permanent magnets is proposed, motivated, and detailed. In order to demonstrate the differences between these models, bar and horseshoe magnets are considered. The structure of the boundary value problem for the magnetic field and related solution techniques are discussed. For the ideal model, closed-form analytical solutions were obtained for both geometries. Magnetic fields of the boundary value problems for both models and differently shaped magnets were computed numerically by using the boundary element method. The results show that the character of the magnetic field is strongly influenced by the model that is used. Furthermore, it can be observed that the shape of an affine-linear magnet influences the near-field significantly. Qualitative comparisons with experiments suggest that both the ideal and the affine-linear models are relevant in practice, depending on the magnetic material employed. Mathematically speaking, the ideal magnetic model is a special case of the affine-linear one. Therefore, in applications where knowledge of the near-field is important, the affine-linear model can yield more accurate results—depending on the magnetic material.

  17. Linear Magnetoelectric Effect by Orbital Magnetism

    NARCIS (Netherlands)

    Scaramucci, A.; Bousquet, E.; Fechner, M.; Mostovoy, M.; Spaldin, N. A.

    2012-01-01

    We use symmetry analysis and first-principles calculations to show that the linear magnetoelectric effect can originate from the response of orbital magnetic moments to the polar distortions induced by an applied electric field. Using LiFePO4 as a model compound we show that spin-orbit coupling

  18. A tubular hybrid Halbach/axially-magnetized permanent-magnet linear machine

    Directory of Open Access Journals (Sweden)

    Yi Sui

    2017-05-01

    Full Text Available A single-phase tubular permanent-magnet linear machine (PMLM with hybrid Halbach/axially-magnetized PM arrays is proposed for free-piston Stirling power generation system. Machine topology and operating principle are elaborately illustrated. With the sinusoidal speed characteristic of the free-piston Stirling engine considered, the proposed machine is designed and calculated by finite-element analysis (FEA. The main structural parameters, such as outer radius of the mover, radial length of both the axially-magnetized PMs and ferromagnetic poles, axial length of both the middle and end radially-magnetized PMs, etc., are optimized to improve both the force capability and power density. Compared with the conventional PMLMs, the proposed machine features high mass and volume power density, and has the advantages of simple control and low converter cost. The proposed machine topology is applicable to tubular PMLMs with any phases.

  19. A tubular hybrid Halbach/axially-magnetized permanent-magnet linear machine

    Science.gov (United States)

    Sui, Yi; Liu, Yong; Cheng, Luming; Liu, Jiaqi; Zheng, Ping

    2017-05-01

    A single-phase tubular permanent-magnet linear machine (PMLM) with hybrid Halbach/axially-magnetized PM arrays is proposed for free-piston Stirling power generation system. Machine topology and operating principle are elaborately illustrated. With the sinusoidal speed characteristic of the free-piston Stirling engine considered, the proposed machine is designed and calculated by finite-element analysis (FEA). The main structural parameters, such as outer radius of the mover, radial length of both the axially-magnetized PMs and ferromagnetic poles, axial length of both the middle and end radially-magnetized PMs, etc., are optimized to improve both the force capability and power density. Compared with the conventional PMLMs, the proposed machine features high mass and volume power density, and has the advantages of simple control and low converter cost. The proposed machine topology is applicable to tubular PMLMs with any phases.

  20. Magnetic separation in microfluidic systems

    DEFF Research Database (Denmark)

    Smistrup, Kristian

    2007-01-01

    to facilitate real-time monitoring of the experiments. The set-up and experimental protocol are described in detail. Results are presented for ’active’ magnetic bead separators, where on-chip microfabricated electromagnets supply the magnetic field and field gradients necessary for magnetic bead separation....... It is shown conceptually how such a system can be applied for parallel biochemical processing in a microfluidic system. ’Passive’ magnetic separators are presented, where on-chip soft magnetic elements are magnetized by an external magnetic field and create strong magnetic fields and gradients inside...

  1. A magnetic biosensor system for detection of E. coli

    KAUST Repository

    Li, Fuquan

    2013-07-01

    This work describes a device for detecting E. coli bacteria by manipulating superparamagnetic beads to a sensing area and immobilizing them in a trapping well. The trapping well replaces the biochemical immobilization layer, which is commonly used in magnetic biosensor systems. A concept exploiting the volume difference between bare magnetic beads and magnetic bead-bioanalyte compounds is utilized to detect E. coli bacteria. Trapped beads are detected by the help of a tunnel magneto-resistive sensor. Frequency modulation is employed, in order to increase the signal-to-noise ratio, enabling the detection of individual superparamagnetic beads of 2.8 μm in diameter. Replacing the biochemical immobilization layer by the trapping well greatly simplifies the detection process. After applying the mixture of E. coli and magnetic beads to the biosensor system, bacteria detection is achieved in a single step, within a few minutes. © 2013 IEEE.

  2. Biosensing based on magnetically induced self-assembly of particles in magnetic colloids.

    Science.gov (United States)

    Yang, Ye; Morimoto, Yoshitaka; Takamura, Tsukasa; Sandhu, Adarsh

    2012-03-01

    Superparamagnetic beads and nonmagnetic beads of different sizes were assembled to form a "ring-structure" in a magnetorheological (MR) fluid solution by the application of external magnetic fields. For superparamagnetic beads and non-magnetic beads functionalized with probe and target molecules, respectively, the ring-structure was maintained even after removing the external magnetic field due to biomolecular bonding. Several experiments are described, including the formation process of ring-structures with and without molecular interactions, the accelerating effect of external magnetic fields, and the effect of biotin concentration on the structures of the rings. We define the small nonmagnetic particles as "petals" because the whole structure looks like a flower. The number of remnant ring petals was a function of the concentration of target molecules in the concentration range of 0.0768 ng/ml-3.8419 ng/ml which makes this protocol a promising method for biosensing. Not only was the formation process rapid, but the resulting two-dimensional colloidal system also offers a simple method for reducing reagent consumption and waste generation.

  3. Peptidome profiling of human serum of uveal melanoma patients based on magnetic bead fractionation and mass spectrometry

    Directory of Open Access Journals (Sweden)

    Xiang-Yu Shi

    2017-06-01

    Full Text Available AIM: To find new biomarkers for uveal melanoma (UM by analyzing the serum peptidome profile. METHODS: Proteomic spectra in patients with UM before and after operation were analyzed and compared with those of healthy controls. Magnetic affinity beads were used to capture serum peptides and matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF mass spectrometer were used to compile serum peptide profiles. RESULTS: A panel of 49 peptides were differentially expressed between UM patients and controls, of which 33 peptides were of higher intensities in patient group and 16 peptides were of higher intensities in control group. Based on combined use of these potential markers, peptides with mean molecular masses of 1467 and 9289.0 Da provide high sensitivity (83.3%, specificity (100% and accuracy rate (93.0% together to differentiate melanoma patients from healthy controls. At the time point of 6mo postoperatively, the levels of many peptides differentially expressed before surgery showed no more statistical difference between the patients and the control group. Fibrinogen α-chain precursors were identified as potential UM markers. CONCLUSION: We have shown that a convenient and fast proteomic technique, affinity bead separation and MALDI-TOF analysis combined with bioinformatic software, facilitates the identification of novel biomarkers for UM.

  4. Flow-orthogonal bead oscillation in a microfluidic chip with a magnetic anisotropic flux-guide array

    DEFF Research Database (Denmark)

    Van Pelt, Stijn; Derks, Roy; Matteucci, Marco

    2011-01-01

    A new concept for the manipulation of superparamagnetic beads inside a microfluidic chip is presented in this paper. The concept allows for bead actuation orthogonal to the flow direction inside a microchannel. Basic manipulation functionalities were studied by means of finite element simulations...

  5. Magnetic bead and gold nanoparticle probes based immunoassay for β-casein detection in bovine milk samples.

    Science.gov (United States)

    Li, Y S; Meng, X Y; Zhou, Y; Zhang, Y Y; Meng, X M; Yang, L; Hu, P; Lu, S Y; Ren, H L; Liu, Z S; Wang, X R

    2015-04-15

    In this work, a double-probe based immunoassay was developed for rapid and sensitive determination of β-casein in bovine milk samples. In the method, magnetic beads (MBs), employed as supports for the immobilization of anti-β-casein polyclonal antibody (PAb), were used as the capture probe. Colloidal gold nanoparticles (AuNPs), employed as a bridge for loading anti-β-casein monoclonal antibody (McAb) and horseradish peroxidase (HRP), were used as the amplification probe. The presence of β-casein causes the sandwich structures of MBs-PAb-β-casein-McAb-AuNPs through the interaction between β-casein and the anti-β-casein antibodies. The HRP, used as an enzymatic-amplified tracer, can catalytically oxidize the substrate 3,3',5,5'-tetramethylbenzidine (TMB), generating optical signals that are proportional to the quantity of β-casein. The linear range of the immunoassay was from 6.5 to 1520ngmL(-1). The limit of detection (LOD) was 4.8ngmL(-1) which was 700 times lower than that of MBs-antibody-HRP based immunoassay and 6-7 times lower than that from the microplate-antibody-HRP based assay. The recoveries of β-casein from bovine milk samples were from 95.0% to 104.3% that had a good correlation coefficient (R(2)=0.9956) with those obtained by an official standard Kjeldahl method. For higher sensitivity, simple sample pretreatment and shorter time requirement of the antigen-antibody reaction, the developed immunoassay demonstrated the viability for detection of β-casein in bovine milk samples. Copyright © 2014. Published by Elsevier B.V.

  6. Preparation and Characterization of Super-paramagnetic Nano-beads for DNA Isolation

    Institute of Scientific and Technical Information of China (English)

    Xin XIE; Xu ZHANG; Bing Bin YU; wei Yang FE

    2004-01-01

    Unique coupling reagent, bis-(2-hydroxyethyl methacrylate) phosphate was used to prepare coated and functionalized superparamagnetic nanobeads, leading to a simple, effective method for coating the nanobeads. With this method, the thickness of the coating layer and the functional group contents on the nano-beads could be controlled by changing the quantity of the coated monomers. The nanobeads were characterized by means of transmission electron microscopy (TEM) and Fourier transformation infrared spectroscopy (FTIR). The carboxyl-modified magnetic nano-beads were employed to streamline the protocol of isolation of genomic DNA from the human whole blood.

  7. Non linear permanent magnets modelling with the finite element method

    International Nuclear Information System (INIS)

    Chavanne, J.; Meunier, G.; Sabonnadiere, J.C.

    1989-01-01

    In order to perform the calculation of permanent magnets with the finite element method, it is necessary to take into account the anisotropic behaviour of hard magnetic materials (Ferrites, NdFeB, SmCo5). In linear cases, the permeability of permanent magnets is a tensor. This one is fully described with the permeabilities parallel and perpendicular to the easy axis of the magnet. In non linear cases, the model uses a texture function which represents the distribution of the local easy axis of the cristallytes of the magnet. This function allows a good representation of the angular dependance of the coercitive field of the magnet. As a result, it is possible to express the magnetic induction B and the tensor as functions of the field and the texture parameter. This model has been implemented in the software FLUX3D where the tensor is used for the Newton-Raphson procedure. 3D demagnetization of a ferrite magnet by a NdFeB magnet is a suitable representative example. They analyze the results obtained for an ideally oriented ferrite magnet and a real one using a measured texture parameter

  8. Synthesis and applications of magnetic nanoparticles for biorecognition and point of care medical diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Sandhu, Adarsh [Electronics-Inspired Interdisciplinary Research Institute (EIIRIS), Toyohashi University of Technology, 1-1 Hibarigaoka, Tempaku, Toyohashi 441-8580 (Japan); Handa, Hiroshi [Integrated Research Institute, Tokyo Institute of Technology, Yokohama 226-8503 (Japan); Abe, Masanori [Department of Electrical and Electronic Engineering, Tokyo Institute of Technology, 2-12-1 O-okayama, Meguro-ku, Tokyo 152-8552 (Japan)

    2010-11-05

    sized 'probe beads' by nanometer sized 'target beads', enabling the detection of small concentrations of beads as small as 8 nm in 'pumpless' microcapillary systems. Finally, we describe a 'label-less homogeneous' procedure referred to as 'magneto-optical transmission (MT) sensing', where the optical transmission of a solution containing rotating linear chains of magnetic nanobeads was used to detect biomolecules with pM-level sensitivity with a dynamic range of more than four orders of magnitude. Our research on the synthesis and applications of nanoparticles is particularly suitable for point of care diagnostics. (topical review)

  9. Simulation of magnetic induction distribution in a coaxial linear motor with axial and radial direction of permanent magnets magnetization

    Directory of Open Access Journals (Sweden)

    G.M. Golenkov

    2014-03-01

    Full Text Available The paper presents results of computer simulation and experimental study of magnetic induction distribution in a coaxial linear motor air gap throughout the length of the runner active part at different heights of the air gap between the runner and the inductor magnetic core for motors with axial and radial direction of the permanent magnets magnetization.

  10. Stanford Linear Collider magnet positioning

    International Nuclear Information System (INIS)

    Wand, B.T.

    1991-08-01

    For the installation of the Stanford Linear Collider (SLC) the positioning and alignment of the beam line components was performed in several individual steps. In the following the general procedures for each step are outlined. The calculation of ideal coordinates for the magnets in the entire SLC will be discussed in detail. Special emphasis was given to the mathematical algorithms and geometry used in the programs to calculate these ideal positions. 35 refs., 21 figs

  11. Sangadzhi Kononov, Buddhist Prayer Beads

    OpenAIRE

    Churyumov, Anton; Kovaeva, Bair

    2016-01-01

    Prayer beads have special dividers that divide the beads into 7, 21 and 33. Apart from using in prayers, the Kalmyks also keep beads as amulets that are believed to have strong energy. After prayers, old people often bless their children and grandchildren with their beads. Such beads are also kept in families from one generation to the next. Sangadzhi believes that prayer beads store inside them the energy of mantras that have been read with them. There is an interesting story about the pray...

  12. Force measurements of a magnetic micro actuator proposed for a microvalve array

    International Nuclear Information System (INIS)

    Chang, Pauline J; Chang, Frank W; Yuen, Michelle C; Horsley, David A; Otillar, Robert

    2014-01-01

    Low-cost, easily-fabricated and power-efficient microvalves are necessary for many microfluidic lab-on-a-chip applications. In this study, we present a simple, low-power, scalable, CMOS-compatible magnetic actuator for microvalve applications composed of a paramagnetic bead as the ball valve over a picoliter reaction well etched into a silicon substrate. The paramagnetic bead, composed of either pure FeSi or magnetite in a SiO 2  matrix, is actuated by the local magnetic field gradient generated by a microcoil in an aqueous environment, and the reaction well is situated at the microcoil center. A permanent magnet beneath the microvalve device provides an external magnetic biasing field that magnetizes the bead, enabling bidirectional actuation and reducing the current required to actuate the bead to a level below 10 mA. The vertical and radial magnetic forces exerted on the bead by the microcoil were measured for both pure FeSi and composite beads and agree well with the predictions of 2D axisymmetric finite element method models. Vertical forces were within a range of 13–80 nN, and radial forces were 11–60 nN depending on the bead type. The threshold current required to initiate bead actuation was measured as a function of bead diameter and is found to scale inversely with volume for small beads, as expected based on the magnetic force model. To provide an estimate of the stiction force acting between the bead and the passivation layer on the substrate, repeated actuation trials were used to study the bead throw distance for substrates coated with silicon dioxide, Parylene-C, and photoresist. The stiction observed was lowest for a photoresist-coated substrate, while silicon dioxide and Parylene-C coated substrates exhibited similar levels of stiction. (paper)

  13. Sequestering HMGB1 via DNA-Conjugated Beads Ameliorates Murine Colitis

    Science.gov (United States)

    Antoine, Daniel J.; Dancho, Meghan; Tsaava, Teá; Li, Jianhua; Lu, Ben; Levine, Yaakov A.; Stiegler, Andrew; Tamari, Yehuda; Al-Abed, Yousef; Roth, Jesse; Tracey, Kevin J.; Yang, Huan

    2014-01-01

    Inflammatory bowel disease (IBD) is chronic inflammation of the gastrointestinal tract that affects millions of people worldwide. Although the etiology of IBD is not clear, it is known that products from stressed cells and enteric microbes promote intestinal inflammation. High mobility group box 1 (HMGB1), originally identified as a nuclear DNA binding protein, is a cytokine-like protein mediator implicated in infection, sterile injury, autoimmune disease, and IBD. Elevated levels of HMGB1 have been detected in inflamed human intestinal tissues and in feces of IBD patients and mouse models of colitis. Neutralizing HMGB1 activity by administration of anti-HMGB1 antibodies or HMGB1-specific antagonist improves clinical outcomes in animal models of colitis. Since HMGB1 binds to DNA with high affinity, here we developed a novel strategy to sequester HMGB1 using DNA immobilized on sepharose beads. Screening of DNA-bead constructs revealed that B2 beads, one linear form of DNA conjugated beads, bind HMGB1 with high affinity, capture HMGB1 ex vivo from endotoxin-stimulated RAW 264.7 cell supernatant and from feces of mice with colitis. Oral administration of B2 DNA beads significantly improved body weight, reduced colon injury, and suppressed colonic and circulating cytokine levels in mice with spontaneous colitis (IL-10 knockout) and with dextran sulfate sodium-induced colitis. Thus, DNA beads reduce inflammation by sequestering HMGB1 and may have therapeutic potential for the treatment of IBD. PMID:25127031

  14. Preliminary experimental results from a linear reciprocating magnetic refrigerator prototype

    International Nuclear Information System (INIS)

    Tagliafico, Luca Antonio; Scarpa, Federico; Valsuani, Federico; Tagliafico, Giulio

    2013-01-01

    A linear reciprocating magnetic refrigerator prototype was designed and built with the aid of an industrial partner. The refrigerator is based on the Active Magnetic Regenerative cycle, and exploits two regenerators working in parallel. The active material is Gadolinium in plates, 0.8 mm thick, for a total mass of 0.36 kg. The device is described and results about magnetic field and temperature span measurements are presented. The designed permanent magnet structure, based on an improved cross-type arrangement, generates a maximum magnetic field intensity of 1.55 T in air, over a gap of (13 × 50 × 100) mm 3 . The maximum temperature span achieved is 5.0 K, in a free run condition. -- Highlights: ► We give preliminary results from a linear reciprocating magnetic refrigerator prototype. ► The design is intended to process visualization and investigation. ► The prototype behavior gives us various suggestions to improve its general performance

  15. Linear magnetic spring and spring/motor combination

    Science.gov (United States)

    Patt, Paul J. (Inventor); Stolfi, Fred R. (Inventor)

    1991-01-01

    A magnetic spring, or a spring and motor combination, providing a linear spring force characteristic in each direction from a neutral position, in which the spring action may occur for any desired coordinate of a typical orthogonal coordinate system. A set of magnets are disposed, preferably symmetrically about a coordinate axis, poled orthogonally to the desired force direction. A second set of magnets, respectively poled opposite the first set, are arranged on the sprung article. The magnets of one of the sets are spaced a greater distance apart than those of the other, such that an end magnet from each set forms a pair having preferably planar faces parallel to the direction of spring force, the faces being offset so that in a neutral position the outer edge of the closer spaced magnet set is aligned with the inner edge of the greater spaced magnet set. For use as a motor, a coil can be arranged with conductors orthogonal to both the magnet pole directions and the direction of desired spring force, located across from the magnets of one set and fixed with respect to the magnets of the other set. In a cylindrical coordinate system having axial spring force, the magnets are radially poled and motor coils are concentric with the cylinder axis.

  16. Development and characterization of a magnetic bead-quantum dot nanoparticles based assay capable of Escherichia coli O157:H7 quantification

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Gha-Young [Department of Civil Engineering, Auburn University, Auburn, AL 36849 (United States); Son, Ahjeong, E-mail: ason@auburn.edu [Department of Civil Engineering, Auburn University, Auburn, AL 36849 (United States)

    2010-09-10

    The development and characterization of a magnetic bead (MB)-quantum dot (QD) nanoparticles based assay capable of quantifying pathogenic bacteria is presented here. The MB-QD assay operates by having a capturing probe DNA selectively linked to the signaling probe DNA via the target genomic DNA (gDNA) during DNA hybridization. The signaling probe DNA is labeled with fluorescent QD{sub 565} which serves as a reporter. The capturing probe DNA is conjugated simultaneously to a MB and another QD{sub 655}, which serve as a carrier and an internal standard, respectively. Successfully captured target gDNA is separated using a magnetic field and is quantified via a spectrofluorometer. The use of QDs (i.e., QD{sub 565}/QD{sub 655}) as both a fluorescence label and an internal standard increased the sensitivity of the assay. The passivation effect and the molar ratio between QD and DNA were optimized. The MB-QD assay demonstrated a detection limit of 890 zeptomolar (i.e., 10{sup -21} mol L{sup -1}) concentration for the linear single stranded DNA (ssDNA). It also demonstrated a detection limit of 87 gene copies for double stranded DNA (dsDNA) eaeA gene extracted from pure Escherichia coli (E. coli) O157:H7 culture. Its corresponding dynamic range, sensitivity, and selectivity were also presented. Finally, the bacterial gDNA of E. coli O157:H7 was used to highlight the MB-QD assay's ability to detect below the minimum infective dose (i.e., 100 organisms) of E. coli O157:H7 in water environment.

  17. Novel Approach to Linear Accelerator Superconducting Magnet System

    International Nuclear Information System (INIS)

    Kashikhin, Vladimir

    2011-01-01

    Superconducting Linear Accelerators include a superconducting magnet system for particle beam transportation that provides the beam focusing and steering. This system consists of a large number of quadrupole magnets and dipole correctors mounted inside or between cryomodules with SCRF cavities. Each magnet has current leads and powered from its own power supply. The paper proposes a novel approach to magnet powering based on using superconducting persistent current switches. A group of magnets is powered from the same power supply through the common, for the group of cryomodules, electrical bus and pair of current leads. Superconducting switches direct the current to the chosen magnet and close the circuit providing the magnet operation in a persistent current mode. Two persistent current switches were fabricated and tested. In the paper also presented the results of magnetic field simulations, decay time constants analysis, and a way of improving quadrupole magnetic center stability. Such approach substantially reduces the magnet system cost and increases the reliability.

  18. Performance Comparison of Permanent Magnet Linear Actuators of Different Mover Types

    DEFF Research Database (Denmark)

    Ritchie, Ewen; Hinov, K.; Yatchev, I.

    2006-01-01

    A comparative study of permanent magnet linear actuators with different location of the permanent magnet is reported. Three mover types are considered - soft magnetic mover, permanent magnet mover and hybrid mover. Force-stroke characteristics are obtained with the help of finite element models...

  19. Superstrong Adjustable Permanent Magnet for a Linear Collider Final Focus

    CERN Document Server

    Iwashita, Y

    2004-01-01

    Super-strong permanent magnets are being considered as one of the candidates for the final focus quadrupole magnets in a linear collider. A short prototype with temperature compensation included and variable strength capability has been designed and fabricated. Fabrication details and some magnetic measurement results will be presented.

  20. A two-channel detection method for autofluorescence correction and efficient on-bead screening of one-bead one-compound combinatorial libraries using the COPAS fluorescence activated bead sorting system

    International Nuclear Information System (INIS)

    Hintersteiner, Martin; Auer, Manfred

    2013-01-01

    One-bead one-compound combinatorial library beads exhibit varying levels of autofluorescence after solid phase combinatorial synthesis. Very often this causes significant problems for automated on-bead screening using TentaGel beads and fluorescently labeled target proteins. Herein, we present a method to overcome this limitation when fluorescence activated bead sorting is used as the screening method. We have equipped the COPAS bead sorting instrument with a high-speed profiling unit and developed a spectral autofluorescence correction method. The correction method is based on a simple algebraic operation using the fluorescence data from two detection channels and is applied on-the-fly in order to reliably identify hit beads by COPAS bead sorting. Our method provides a practical tool for the fast and efficient isolation of hit beads from one-bead one-compound library screens using either fluorescently labeled target proteins or biotinylated target proteins. This method makes hit bead identification easier and more reliable. It reduces false positives and eliminates the need for time-consuming pre-sorting of library beads in order to remove autofluorescent beads. (technical note)

  1. Magnetic Bead-Based Serum Peptidome Profiling in Patients with Gestational Diabetes Mellitus

    Directory of Open Access Journals (Sweden)

    Tingting Ai

    2015-01-01

    Full Text Available Gestational diabetes mellitus (GDM is a frequent medical condition during pregnancy. Early diagnosis and treatment of GDM are crucial for both the mother and the baby. In the present study, we aimed to identify specific biomarkers to assist in the early detection of GDM and give some clues to the possible causes of GDM by comparing serum peptide profile differences between GDM patients and healthy controls. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS was used in combination with weak cation exchange magnetic bead (WCX-MB. Levels of four peptides (4418.9, 2219.7, 2211.5, and 1533.4 Da were significantly different. Interestingly, three of them (4418.9, 2211.5, and 1533.4 Da were identified when GDM patients with two degrees of glucose intolerance were compared. Additionally, peptides 2211.5 and 1533.4 Da showed a decreasing trend as glucose intolerance increased, while peptide 4418.9 Da exhibited the reverse tendency. In conclusion, our study provides novel insights into the altered serum peptide profile of GDM patients. The specific candidate biomarkers may contribute to the development of GDM.

  2. New Nanoparticles Dispersing Beads Mill with Ultra Small Beads and its Application

    International Nuclear Information System (INIS)

    Inkyo, M; Tahara, T; Imajyo, Y

    2011-01-01

    Two of the major problems related to nanoparticle dispersion with a conventional beads mill are re-agglomeration and damage to the crystalline structure of the particles. The Ultra Apex Mill was developed to solve these problems by enabling the use of ultra-small beads with a diameter of less than 0.1mm. The core of this breakthrough development is centrifugation technology which allows the use of beads as small as 0.015mm. When dispersing agglomerated nanoparticles the impulse of the small beads is very low which means there is little influence on the particles. The surface energy of the nanoparticles remains low so the properties are not likely to change. As a result, stable nanoparticle dispersions can be achieved without re-cohesion. The Ultra Apex Mill is superior to conventional beads mills that are limited to much larger bead sizes. The technology of the Ultra Apex Mill has pioneered practical applications for nanoparticles in various fields: composition materials for LCD screens, ink-jet printing, ceramic condensers and cosmetics.

  3. Artificial intelligence versus statistical modeling and optimization of continuous bead milling process for bacterial cell lysis

    Directory of Open Access Journals (Sweden)

    Shafiul Haque

    2016-11-01

    Full Text Available AbstractFor a commercially viable recombinant intracellular protein production process, efficient cell lysis and protein release is a major bottleneck. The recovery of recombinant protein, cholesterol oxidase (COD was studied in a continuous bead milling process. A full factorial Response Surface Model (RSM design was employed and compared to Artificial Neural Networks coupled with Genetic Algorithm (ANN-GA. Significant process variables, cell slurry feed rate (A, bead load (B, cell load (C and run time (D, were investigated and optimized for maximizing COD recovery. RSM predicted an optimum of feed rate of 310.73 mL/h, bead loading of 79.9% (v/v, cell loading OD600 nm of 74, and run time of 29.9 min with a recovery of ~3.2 g/L. ANN coupled with GA predicted a maximum COD recovery of ~3.5 g/L at an optimum feed rate (mL/h: 258.08, bead loading (%, v/v: 80%, cell loading (OD600 nm: 73.99, and run time of 32 min. An overall 3.7-fold increase in productivity is obtained when compared to a batch process. Optimization and comparison of statistical vs. artificial intelligence techniques in continuous bead milling process has been attempted for the very first time in our study. We were able to successfully represent the complex non-linear multivariable dependence of enzyme recovery on bead milling parameters. The quadratic second order response functions are not flexible enough to represent such complex non-linear dependence. ANN being a summation function of multiple layers are capable to represent complex non-linear dependence of variables in this case; enzyme recovery as a function of bead milling parameters. Since GA can even optimize discontinuous functions present study cites a perfect example of using machine learning (ANN in combination with evolutionary optimization (GA for representing undefined biological functions which is the case for common industrial processes involving biological moieties.

  4. Molecular diagnostics using magnetic nanobeads

    International Nuclear Information System (INIS)

    Zardan Gomez de la Torre, Teresa; Stroemberg, Mattias; Goeransson, Jenny; Stroemme, Maria; Gunnarsson, Klas; Svedlindh, Peter; Nilsson, Mats

    2010-01-01

    In this paper, we investigate the volume-amplified magnetic nanobead detection assay with respect to bead size, bead concentration and bead oligonucleotide surface coverage in order to improve the understanding of the underlying microscopic mechanisms. It has been shown that: (i) the immobilization efficiency of the beads depends on the surface coverage of oligonucleotides, (ii) by using lower amounts of probe-tagged beads, detection sensitivity can be improved and (iii) using small enough beads enables both turn-off and turn-on detection. Finally, biplex detection was demonstrated.

  5. Modeling and analysis of mover gaps in tubular moving-magnet linear oscillating motors

    Directory of Open Access Journals (Sweden)

    Xuesong LUO

    2018-05-01

    Full Text Available A tubular moving-magnet linear oscillating motor (TMMLOM has merits of high efficiency and excellent dynamic capability. To enhance the thrust performance, quasi-Halbach permanent magnet (PM arrays are arranged on its mover in the application of a linear electro-hydrostatic actuator in more electric aircraft. The arrays are assembled by several individual segments, which lead to gaps between them inevitably. To investigate the effects of the gaps on the radial magnetic flux density and the machine thrust in this paper, an analytical model is built considering both axial and radial gaps. The model is validated by finite element simulations and experimental results. Distributions of the magnetic flux are described in condition of different sizes of radial and axial gaps. Besides, the output force is also discussed in normal and end windings. Finally, the model has demonstrated that both kinds of gaps have a negative effect on the thrust, and the linear motor is more sensitive to radial ones. Keywords: Air-gap flux density, Linear motor, Mover gaps, Quasi-Halbach array, Thrust output, Tubular moving-magnet linear oscillating motor (TMMLOM

  6. A bead-spring chain as a one-dimensional polyelectrolyte gel.

    Science.gov (United States)

    Manning, Gerald S

    2018-05-23

    The physical principles underlying expansion of a single-chain polyelectrolyte coil caused by Coulomb repulsions among its ionized groups, and the expansion of a cross-linked polyelectrolyte gel, are probably the same. In this paper, we analyze a "one-dimensional" version of a gel, namely, a linear chain of charged beads connected by Hooke's law springs. In the Debye-Hückel range of relatively weak Coulomb strength, where counterion condensation does not occur, the springs are realistically stretched on a nanolength scale by the repulsive interactions among the beads, if we use a spring constant normalized by the inverse square of the solvent Bjerrum length. The persistence length and radius of gyration counter-intuitively decrease when Coulomb strength is increased, if analyzed in the framework of an OSF-type theory; however, a buckling theory generates the increase that is consistent with bead-spring simulations.

  7. Angiotensin converting enzyme immobilized on magnetic beads as a tool for ligand fishing.

    Science.gov (United States)

    de Almeida, Fernando G; Vanzolini, Kenia L; Cass, Quezia B

    2017-01-05

    Angiotensin converting enzyme (ACE) presents an important role in blood pressure regulation, since that converts angiotensin I to the vasoconstrictor angiotensin II. Some commercially available ACE inhibitors are captopril, lisinopril and enalapril; due to their side effects, naturally occurring inhibitors have been prospected. In order to endorse this research field we have developed a new tool for ACE ligand screening. To this end, ACE was extracted from bovine lung, purified and chemically immobilized in modified ferrite magnetic beads (ACE-MBs). The ACE-MBs have shown a Michaelian kinetic behavior towards hippuryl-histidyl-leucine. Moreover, as proof of concept, the ACE-MBs was inhibited by lisinopril with a half maximal inhibitory concentration (IC 50 ) of 10nM. At the fishing assay, ACE-MBs were able not only to fish out the reference inhibitor, but also one peptide from a pool of tryptic digested BSA. In conclusion, ACE-MBs emerge as new straightforward tool for ACE kinetics determination, inhibition and binder screening. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Investigation and Calculation of Magnetic Field in Tubular Linear Reluctance Motor Using FEM

    Directory of Open Access Journals (Sweden)

    MOSALLANEJAD, A.

    2010-11-01

    Full Text Available In this paper the magnetic flux density of tubular linear reluctance motor (TLRM in open type magnetic circuit is studied. Also, all magnetic flux density calculation methods in winding of tubular linear reluctance motor are described. The effect of structure parameters on magnetic flux density is also discussed. Electromagnetic finite-element analysis is used for simulation of magnetic field, and simulation results of the magnetic field analysis with DC voltage excitation are compared with results obtained from calculation methods. The comparison yields a good agreement.

  9. Magnetic Beads-Based Sensor with Tailored Sensitivity for Rapid and Single-Step Amperometric Determination of miRNAs

    Directory of Open Access Journals (Sweden)

    Eva Vargas

    2017-11-01

    Full Text Available This work describes a sensitive amperometric magneto-biosensor for single-step and rapid determination of microRNAs (miRNAs. The developed strategy involves the use of direct hybridization of the target miRNA (miRNA-21 with a specific biotinylated DNA probe immobilized on streptavidin-modified magnetic beads (MBs, and labeling of the resulting heteroduplexes with a specific DNA–RNA antibody and the bacterial protein A (ProtA conjugated with an horseradish peroxidase (HRP homopolymer (Poly-HRP40 as an enzymatic label for signal amplification. Amperometric detection is performed upon magnetic capture of the modified MBs onto the working electrode surface of disposable screen-printed carbon electrodes (SPCEs using the H2O2/hydroquinone (HQ system. The magnitude of the cathodic signal obtained at −0.20 V (vs. the Ag pseudo-reference electrode demonstrated linear dependence with the concentration of the synthetic target miRNA over the 1.0 to 100 pM range. The method provided a detection limit (LOD of 10 attomoles (in a 25 μL sample without any target miRNA amplification in just 30 min (once the DNA capture probe-MBs were prepared. This approach shows improved sensitivity compared with that of biosensors constructed with the same anti-DNA–RNA Ab as capture instead of a detector antibody and further labeling with a Strep-HRP conjugate instead of the Poly-HRP40 homopolymer. The developed strategy involves a single step working protocol, as well as the possibility to tailor the sensitivity by enlarging the length of the DNA/miRNA heteroduplexes using additional probes and/or performing the labelling with ProtA conjugated with homopolymers prepared with different numbers of HRP molecules. The practical usefulness was demonstrated by determination of the endogenous levels of the mature target miRNA in 250 ng raw total RNA (RNAt extracted from human mammary epithelial normal (MCF-10A and cancer (MCF-7 cells and tumor tissues.

  10. Optimization of Linear Permanent Magnet (PM Generator with Triangular-Shaped Magnet for Wave Energy Conversion using Finite Element Method

    Directory of Open Access Journals (Sweden)

    Aamir Hussain

    2016-06-01

    Full Text Available This paper presents the design optimization of linear permanent magnet (PM generator for wave energy conversion using finite element method (FEM. A linear PM generator with triangular-shaped magnet is proposed, which has higher electromagnetic characteristics, superior performance and low weight as compared to conventional linear PM generator with rectangular shaped magnet. The Individual Parameter (IP optimization technique is employed in order to optimize and achieve optimum performance of linear PM generator. The objective function, optimization variables; magnet angle,M_θ(∆ (θ, the pole-width ratio, P_w ratio(τ_p/τ_mz,, and split ratio between translator and stator, δ_a ratio(R_m/R_e, and constraints are defined. The efficiency and its main parts; copper and iron loss are computed using time-stepping FEM. The optimal values after optimization are presented which yields highest efficiency. Key

  11. Friction of N-bead macromolecules in solution: Effects of the bead-solvent interaction

    International Nuclear Information System (INIS)

    Uvarov, Alexander; Fritzsche, Stephan

    2006-01-01

    The role of the bead-solvent interaction has been studied for its influence on the dynamics of an N-bead macromolecule which is immersed into a solution. Using a Fokker-Planck equation for the phase-space distribution function of the macromolecule, we show that all the effects of the solution can be treated entirely in terms of the friction tensors which are assigned to each pair of interacting beads in the chain. For the high-density as well as for the critical solvent, the properties of these tensors are discussed in detail and are calculated by using several (realistic) choices of the bead-solvent potential. From the friction tensors, moreover, an expression for the center-of-mass friction coefficient of a (N-bead) chain macromolecule is derived. Numerical data for this coefficient for 'truncated' Lennard-Jones bead-solvent potential are compared with results from molecular dynamic simulations and from the phenomenological theoretical data as found in the literature

  12. Structure of yttria stabilized zirconia beads produced by gel supported precipitation

    International Nuclear Information System (INIS)

    Walter, M.; Somers, J.; Fernandez, A.; Specht, Eliot D.; Hunn, John D.; Boulet, P.; Denecke, M. A.; Gobel, C.

    2007-01-01

    Yttria stabilized zirconia (YSZ) is one of the inert matrix candidates selected for investigation as host matrix for minor actinide (MA) transmutation. The structural properties of (Zr0.84, Y0.16)O1.92 beads prepared by a sol-gel method for MA infiltration, are characterized as calcined (850 C) and sintered (1,600 C) beads. The calcined YSZ beads are fine-grained and homogenous over the entire sphere and are surrounded by a uniform outer layer of approximately 30 (micro)m thickness. After sintering at 1,600 C, the beads are compacted to 51% of their initial volume and exhibit a granular structure. The thermal expansion is nearly linear for the calcined material, but shows a parabolic behavior for the sintered (1,400 C) beads. In addition, the thermal expansion of calcined material is 20-25% less than after sintering. During heating up to 1,400 C, two processes can be distinguished. The first occurs between 900 and 1,000 C and is related to an increase in unit cell order. The second process involves grain-growth of the less crystalline calcined material between 1,100 and 1,300 C. These results have implications for preparation of YSZ and its use as an inert MA transmutation matrix

  13. Linear magnetic fusion: summary of Seattle workshop

    International Nuclear Information System (INIS)

    1977-12-01

    The linear-geometry magnetic confinement concept is among the oldest used in the study of high-temperature plasmas. However, it has generally been discounted as a suitable approach for demonstrating controlled thermonuclear fusion because rapid losses from the plasma column ends necessitate very long devices. Further, the losses and how to overcome them have not yet received parametric experimental study, nor do facilities exist with which such definitive experiments could be performed. Nonetheless, the important positive attribute, simplicity, together with the appearance of several ideas for reducing end losses have provided motivation for continued research on linear magnetic fusion (LMF). These motivations led to the LMF workshop, held in Seattle, March 9--11, 1977, which explored the potential of LMF as an alternate approach to fusion. A broad range of LMF aspects were addressed, including radial and axial losses, stability and equilibrium, heating, technology, and reactor considerations. The conclusions drawn at the workshop are summarized

  14. Rapid Detection of Ricin in Serum Based on Cu-Chelated Magnetic Beads Using Mass Spectrometry

    Science.gov (United States)

    Zhao, Yong-Qiang; Song, Jian; Wang, Hong-Li; Xu, Bin; Liu, Feng; He, Kun; Wang, Na

    2016-04-01

    The protein toxin ricin obtained from castor bean plant (Ricinus communis) seeds is a potent biological warfare agent due to its ease of availability and acute toxicity. In this study, we demonstrated a rapid and simple method to detect ricin in serum in vitro. The ricin was mixed with serum and digested by trypsin, then all the peptides were efficiently extracted using Cu-chelated magnetic beads and were detected with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. The specific ricin peptides were identified by Nanoscale Ultra Performance liquid chromatography coupled to tandem mass spectrometry according to their sequences. The assay required 2.5 hours, and a characteristic peptide could be detected down to 4 ng/μl and used as a biomarker to detect ricin in serum. The high sensitivity and simplicity of the procedure makes it valuable in clinical practice.

  15. A non-linear dissipative model of magnetism

    Czech Academy of Sciences Publication Activity Database

    Durand, P.; Paidarová, Ivana

    2010-01-01

    Roč. 89, č. 6 (2010), s. 67004 ISSN 1286-4854 R&D Projects: GA AV ČR IAA100400501 Institutional research plan: CEZ:AV0Z40400503 Keywords : non-linear dissipative model of magnetism * thermodynamics * physical chemistry Subject RIV: CF - Physical ; Theoretical Chemistry http://epljournal.edpsciences.org/

  16. Linear birefringence and optical ativity in a magnetized plasma

    International Nuclear Information System (INIS)

    Vuolo, J.H.; Galvao, R.M.O.

    1982-02-01

    Linear birefringence and optical activity are considered separately to electromagnetic wave propagation in magnetized cold plasma, using frequency approximation much bigger than plasma frequency. It's showen that in some interesting cases, those phenomena could be independents. Explicit expressions are obtained for refraction indices to linear birefringency and optical activity. The correspondents indices attenuation aRe obtained in first orden of attenuation. It's showen that the characteristic states for linear dichroism coincide with the characteristic states for linear birefringence. The characteristic states for elliptic dichroism are obtained. (M.A.F.) [pt

  17. AIRGAP MAGNETIC INDUCTION DISTRIBUTION IN A COAXIALLY-LINEAR SYNCHRONOUS MOTOR WITH AXIAL AND RADIAL DIRECTION OF THE RUNNER PERMANENT MAGNETS MAGNETIZATION

    Directory of Open Access Journals (Sweden)

    Abbasian Mohsen

    2013-02-01

    Full Text Available Results of theoretical and experimental research on magnetic induction distribution in the air gap of a coaxially-linear synchronous motor with reciprocal motion within the pole pitch and axial and radial direction of the permanent magnets magnetization are presented.

  18. Selective extraction of plutonium from nitric acid medium by bifunctional polyethersulfone beads for quantification with thermal ionisation mass spectrometry

    International Nuclear Information System (INIS)

    Paul, Sumana; Aggarwal, S.K.; Pandey, A.K.

    2015-01-01

    Polyethersulfone (PES) magnetic beads were prepared by phase inversion technique. The beads were grafted with two monomers, viz. 2-hydroxyethylmethacrylate phosphoric acid (HEMP) and (3-acrylamidopropyl)trimethyl ammonium chloride (AMAC), by photo-induced free radical polymerization. Effect of different HNO 3 concentrations on the sorption profiles of Am(III) and Pu(IV) was studied using the grafted PES beads. The beads were found to extract plutonium quantitatively from high nitric acid medium (3-8 M). The effect of presence of competing actinide, e.g. U(VI), on the sorption of Pu(IV) was also studied. (author)

  19. New Evidence for the Mechanism of Action of a Type-2 Diabetes Drug Using a Magnetic Bead-Based Automated Biosensing Platform

    DEFF Research Database (Denmark)

    Uddin, Rokon; Nur-E-Habiba; Rena, Graham

    2017-01-01

    The mechanism of action (MOA) of the first line type-2 diabetes drug metformin remains unclear despite its widespread usage. However, recent evidence suggests that the mitochondrial copper (Cu)-binding action of metformin may contribute toward the drug's MOA. Here, we present a novel biosensing...... of metformin's blood-glucose lowering action. In this assay, cysteine-functionalized magnetic beadswere agglutinated in the presence of Cu due to cysteine's Cu-chelation property. Addition of clinically relevant doses of metformin resulted in disaggregation of Cu-bridged bead-clusters, whereas the effect...

  20. Beautiful Beads: A Lesson in Making Beads with Friendly Clay. AMACO[R] Lesson.

    Science.gov (United States)

    Gamble, Harriet; Gamble, David

    This lesson resource includes a brief summary of the history of bead making and historic fascination with beads as adornment. A focus on design elements, color theory, craftsmanship, and technical skill in bead making is encouraged. The plan includes lesson goals and objectives; background preparation; a glossary of terms; a list of supplies; and…

  1. Glass bead cultivation of fungi

    DEFF Research Database (Denmark)

    Droce, Aida; Sørensen, Jens Laurids; Giese, H.

    2013-01-01

    Production of bioactive compounds and enzymes from filamentous fungi is highly dependent on cultivation conditions. Here we present an easy way to cultivate filamentous fungi on glass beads that allow complete control of nutrient supply. Secondary metabolite production in Fusarium graminearum...... and Fusarium solani cultivated on agar plates, in shaking liquid culture or on glass beads was compared. Agar plate culture and glass bead cultivation yielded comparable results while liquid culture had lower production of secondary metabolites. RNA extraction from glass beads and liquid cultures was easier...... to specific nutrient factors. •Fungal growth on glass beads eases and improves fungal RNA extraction....

  2. New Detection Modality for Label-Free Quantification of DNA in Biological Samples via Superparamagnetic Bead Aggregation

    Science.gov (United States)

    Leslie, Daniel C.; Li, Jingyi; Strachan, Briony C.; Begley, Matthew R.; Finkler, David; Bazydlo, Lindsay L.; Barker, N. Scott; Haverstick, Doris; Utz, Marcel; Landers, James P.

    2012-01-01

    Combining DNA and superparamagnetic beads in a rotating magnetic field produces multiparticle aggregates that are visually striking, and enables label-free optical detection and quantification of DNA at levels in the picogram per microliter range. DNA in biological samples can be quantified directly by simple analysis of optical images of microfluidic wells placed on a magnetic stirrer without DNA purification. Aggregation results from DNA/bead interactions driven either by the presence of a chaotrope (a nonspecific trigger for aggregation) or by hybridization with oligonucleotides on functionalized beads (sequence-specific). This paper demonstrates quantification of DNA with sensitivity comparable to that of the best currently available fluorometric assays. The robustness and sensitivity of the method enable a wide range of applications, illustrated here by counting eukaryotic cells. Using widely available and inexpensive benchtop hardware, the approach provides a highly accessible low-tech microscale alternative to more expensive DNA detection and cell counting techniques. PMID:22423674

  3. Direct torque control via feedback linearization for permanent magnet synchronous motor drives

    DEFF Research Database (Denmark)

    Lascu, Cristian; Boldea, Ion; Blaabjerg, Frede

    2012-01-01

    The paper describes a direct torque controlled (DTC) permanent magnet synchronous motor (PMSM) drive that employs feedback linearization and uses sliding-mode and linear controllers. We introduce a new feedback linearization approach that yields a decoupled linear PMSM model with two state...

  4. Linear relativistic gyrokinetic equation in general magnetically confined plasmas

    International Nuclear Information System (INIS)

    Tsai, S.T.; Van Dam, J.W.; Chen, L.

    1983-08-01

    The gyrokinetic formalism for linear electromagnetic waves of arbitrary frequency in general magnetic-field configurations is extended to include full relativistic effects. The derivation employs the small adiabaticity parameter rho/L 0 where rho is the Larmor radius and L 0 the equilibrium scale length. The effects of the plasma and magnetic field inhomogeneities and finite Larmor-radii effects are also contained

  5. A Revised Piecewise Linear Recursive Convolution FDTD Method for Magnetized Plasmas

    International Nuclear Information System (INIS)

    Liu Song; Zhong Shuangying; Liu Shaobin

    2005-01-01

    The piecewise linear recursive convolution (PLRC) finite-different time-domain (FDTD) method improves accuracy over the original recursive convolution (RC) FDTD approach and current density convolution (JEC) but retains their advantages in speed and efficiency. This paper describes a revised piecewise linear recursive convolution PLRC-FDTD formulation for magnetized plasma which incorporates both anisotropy and frequency dispersion at the same time, enabling the transient analysis of magnetized plasma media. The technique is illustrated by numerical simulations of the reflection and transmission coefficients through a magnetized plasma layer. The results show that the revised PLRC-FDTD method has improved the accuracy over the original RC FDTD method and JEC FDTD method

  6. Magnetic Bead Based Immunoassay for Autonomous Detection of Toxins

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Y; Hara, C A; Knize, M G; Hwang, M H; Venkatesteswaran, K S; Wheeler, E K; Bell, P M; Renzi, R F; Fruetel, J A; Bailey, C G

    2008-05-01

    As a step towards toward the development of a rapid, reliable analyzer for bioagents in the environment, we are developing an automated system for the simultaneous detection of a group of select agents and toxins. To detect toxins, we modified and automated an antibody-based approach previously developed for manual medical diagnostics that uses fluorescent eTag{trademark} reporter molecules and is suitable for highly multiplexed assays. Detection is based on two antibodies binding simultaneously to a single antigen, one of which is labeled with biotin while the other is conjugated to a fluorescent eTag{trademark} through a cleavable linkage. Aqueous samples are incubated with the mixture of antibodies along with streptavidin-coated magnetic beads coupled to a photo-activatable porphyrin complex. In the presence of antigen, a molecular complex is formed where the cleavable linkage is held in proximity to the photoactivable group. Upon excitation at 680 nm, free radicals are generated, which diffuse and cleave the linkage, releasing the eTags{trademark}. Released eTags{trademark} are analyzed using capillary gel electrophoresis with laser-induced fluorescence detection. Limits of detection for ovalbumin and botulinum toxoid individually were 4 ng/mL (or 80 pg) and 16 ng/mL (or 320 pg), respectively, using the manual assay. In addition, we demonstrated the use of pairs of antibodies from different sources in a single assay to decrease the rate of false positives. Automation of the assay was demonstrated on a flow-through format with higher LODs of 125 ng/mL (or 2.5 ng) each of a mixture of ovalbumin and botulinum toxoid. This versatile assay can be easily modified with the appropriate antibodies to detect a wide range of toxins and other proteins.

  7. Confocal nanoscanning, bead picking (CONA): PickoScreen microscopes for automated and quantitative screening of one-bead one-compound libraries.

    Science.gov (United States)

    Hintersteiner, Martin; Buehler, Christof; Uhl, Volker; Schmied, Mario; Müller, Jürgen; Kottig, Karsten; Auer, Manfred

    2009-01-01

    Solid phase combinatorial chemistry provides fast and cost-effective access to large bead based libraries with compound numbers easily exceeding tens of thousands of compounds. Incubating one-bead one-compound library beads with fluorescently labeled target proteins and identifying and isolating the beads which contain a bound target protein, potentially represents one of the most powerful generic primary high throughput screening formats. On-bead screening (OBS) based on this detection principle can be carried out with limited automation. Often hit bead detection, i.e. recognizing beads with a fluorescently labeled protein bound to the compound on the bead, relies on eye-inspection under a wide-field microscope. Using low resolution detection techniques, the identification of hit beads and their ranking is limited by a low fluorescence signal intensity and varying levels of the library beads' autofluorescence. To exploit the full potential of an OBS process, reliable methods for both automated quantitative detection of hit beads and their subsequent isolation are needed. In a joint collaborative effort with Evotec Technologies (now Perkin-Elmer Cellular Technologies Germany GmbH), we have built two confocal bead scanner and picker platforms PS02 and a high-speed variant PS04 dedicated to automated high resolution OBS. The PS0X instruments combine fully automated confocal large area scanning of a bead monolayer at the bottom of standard MTP plates with semiautomated isolation of individual hit beads via hydraulic-driven picker capillaries. The quantification of fluorescence intensities with high spatial resolution in the equatorial plane of each bead allows for a reliable discrimination between entirely bright autofluorescent beads and real hit beads which exhibit an increased fluorescence signal at the outer few micrometers of the bead. The achieved screening speed of up to 200,000 bead assayed in less than 7 h and the picking time of approximately 1 bead

  8. Rapid Detection of Enterobacter Sakazakii in milk Powder using amino modified chitosan immunomagnetic beads.

    Science.gov (United States)

    Zhu, Yinglian; Wang, Dongfeng

    2016-12-01

    Chitosan immunomagnetic beads (CIBs) were first prepared through converting hydroxyl groups of natural polymer material-chitosan into amino groups using epichlorohydrin and ethylenediamine as modification agent and then coupling with polyclonal antibodies of Enterobacter sakazakii using glutaraldehyde as cross-linking agent. The beads before coupling with antibodies were characterized by magnetic property measurement, FTIR, SEM and XRD technologies. In the assay a natural polysaccharide-chitosan, which has good biological and chemical properties such as non-toxicity, biocompatibility and high chemical reactivity was first used for synthesis of immunomagnetic beads. The detection method first established in this paper that combined the beads with chromogenic medium together to rapid detect E. sakazakii in milk powder could greatly improve the detection specificity and working efficiency. The beads exhibited a maximum capturing capacity of 1×10 6 cfu/g with the detection sensitivity of 4cfu/g. The results demonstrate that the assay is a straightforward, specific and sensitive alternative for rapid detection of E.sakazakii in food matrix. The total analysis time was as little as about 25h, which greatly shorten the detection time. The method can provides new ideas not only to preparation technique of immunomagnetic beads but to imunne detection technique in food safety. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. 13th International Conference on Magnetically Levitated Systems and Linear Drives

    International Nuclear Information System (INIS)

    1993-01-01

    This report contains short papers on research being conducted throughout the world on magnetically levitated systems, mainly consisting of trains, and magnetic linear drives. These papers have been index separately elsewhere on the data base

  10. 13th International Conference on Magnetically Levitated Systems and Linear Drives

    Energy Technology Data Exchange (ETDEWEB)

    1993-09-01

    This report contains short papers on research being conducted throughout the world on magnetically levitated systems, mainly consisting of trains, and magnetic linear drives. These papers have been index separately elsewhere on the data base.

  11. Design and analysis of tubular permanent magnet linear wave generator.

    Science.gov (United States)

    Si, Jikai; Feng, Haichao; Su, Peng; Zhang, Lufeng

    2014-01-01

    Due to the lack of mature design program for the tubular permanent magnet linear wave generator (TPMLWG) and poor sinusoidal characteristics of the air gap flux density for the traditional surface-mounted TPMLWG, a design method and a new secondary structure of TPMLWG are proposed. An equivalent mathematical model of TPMLWG is established to adopt the transformation relationship between the linear velocity of permanent magnet rotary generator and the operating speed of TPMLWG, to determine the structure parameters of the TPMLWG. The new secondary structure of the TPMLWG contains surface-mounted permanent magnets and the interior permanent magnets, which form a series-parallel hybrid magnetic circuit, and their reasonable structure parameters are designed to get the optimum pole-arc coefficient. The electromagnetic field and temperature field of TPMLWG are analyzed using finite element method. It can be included that the sinusoidal characteristics of air gap flux density of the new secondary structure TPMLWG are improved, the cogging force as well as mechanical vibration is reduced in the process of operation, and the stable temperature rise of generator meets the design requirements when adopting the new secondary structure of the TPMLWG.

  12. Design and Analysis of Tubular Permanent Magnet Linear Wave Generator

    Directory of Open Access Journals (Sweden)

    Jikai Si

    2014-01-01

    Full Text Available Due to the lack of mature design program for the tubular permanent magnet linear wave generator (TPMLWG and poor sinusoidal characteristics of the air gap flux density for the traditional surface-mounted TPMLWG, a design method and a new secondary structure of TPMLWG are proposed. An equivalent mathematical model of TPMLWG is established to adopt the transformation relationship between the linear velocity of permanent magnet rotary generator and the operating speed of TPMLWG, to determine the structure parameters of the TPMLWG. The new secondary structure of the TPMLWG contains surface-mounted permanent magnets and the interior permanent magnets, which form a series-parallel hybrid magnetic circuit, and their reasonable structure parameters are designed to get the optimum pole-arc coefficient. The electromagnetic field and temperature field of TPMLWG are analyzed using finite element method. It can be included that the sinusoidal characteristics of air gap flux density of the new secondary structure TPMLWG are improved, the cogging force as well as mechanical vibration is reduced in the process of operation, and the stable temperature rise of generator meets the design requirements when adopting the new secondary structure of the TPMLWG.

  13. Design and Analysis of Tubular Permanent Magnet Linear Wave Generator

    Science.gov (United States)

    Si, Jikai; Feng, Haichao; Su, Peng; Zhang, Lufeng

    2014-01-01

    Due to the lack of mature design program for the tubular permanent magnet linear wave generator (TPMLWG) and poor sinusoidal characteristics of the air gap flux density for the traditional surface-mounted TPMLWG, a design method and a new secondary structure of TPMLWG are proposed. An equivalent mathematical model of TPMLWG is established to adopt the transformation relationship between the linear velocity of permanent magnet rotary generator and the operating speed of TPMLWG, to determine the structure parameters of the TPMLWG. The new secondary structure of the TPMLWG contains surface-mounted permanent magnets and the interior permanent magnets, which form a series-parallel hybrid magnetic circuit, and their reasonable structure parameters are designed to get the optimum pole-arc coefficient. The electromagnetic field and temperature field of TPMLWG are analyzed using finite element method. It can be included that the sinusoidal characteristics of air gap flux density of the new secondary structure TPMLWG are improved, the cogging force as well as mechanical vibration is reduced in the process of operation, and the stable temperature rise of generator meets the design requirements when adopting the new secondary structure of the TPMLWG. PMID:25050388

  14. Numerical studies on the force characteristic of superconducting linear synchronous motor with HTS bulk magnet

    Science.gov (United States)

    Tang, Junjie; Li, Jing; Li, Xiang; Han, Le

    2018-03-01

    High temperature superconductor (HTS) bulks have significant potential use in linear motor application act as quasi-permanent magnet to replace traditional magnets. Force characteristic between HTS bulk magnet and traveling magnetic field was investigated with numerical simulation and experimental measurement in this paper. Influences of bulk height and number on the force characteristic were studied by the finite element model considering the nonlinear E-J relationship. Study was also made on addition of a back iron plate to the bulk magnet. Besides, force characteristic of bulk was compared with the permanent magnet results. The small initial decrease of the thrust could be explained by inside superconducting current redistribution. It was found that efficiency of linear motor did not increase by adding more bulk magnets. The bulk magnet will be remagnetized instead of erasing trapped field with the increase of the traveling magnetic field strength. The conclusions are helpful in prediction and design the linear motor with HTS bulk magnet.

  15. Analysis and Design of Double-sided Air core Linear Servo Motor with Trapezoidal Permanent Magnets

    DEFF Research Database (Denmark)

    Zhang, Yuqiu; Yang, Zilong; Yu, Minghu

    2011-01-01

    In order to reduce the thrust ripple of linear servo system, a double-sided air core permanent magnet linear servo motor with trapezoidal shape permanent magnets (TDAPMLSM) is proposed in this paper. An analytical model of the motor for predicting the magnetic field in the air-gap at no...

  16. Development of a novel colorimetric sensor based on alginate beads for monitoring rainbow trout spoilage.

    Science.gov (United States)

    Majdinasab, Marjan; Hosseini, Seyed Mohammad Hashem; Sepidname, Marziyeh; Negahdarifar, Manizheh; Li, Peiwu

    2018-05-01

    Alginate is a non-toxic, renewable, and linear copolymer obtained from the brown algae Laminaria digitata that can be easily shaped into beads. Its good gel forming properties have made it useful for entrapping food and pharmaceutical ingredients. In this study, alginate beads were used in a novel application as a colorimetric sensor in food intelligent packaging. Colorimetric sensor was developed through entrapping red cabbage extract as a pH indicator in alginate beads. The pH indicator beads were used in rainbow trout packaging for monitoring fillets spoilage. Color change of beads during fish storage was measured using the CIELab method. The alginate bead colorimetric sensor is validated by measuring total volatile basic nitrogen (TVB-N) levels and microbial populations in fish samples. Moreover, peroxide value (PV) and thiobarbituric acid reactive substances (TBARS) were evaluated during storage. Results indicated that increasing the bacterial population during storage and production of proteolytic enzymes resulted in protein degradation, accumulation of volatile amine compounds, increase in the pH and finally color change of alginate beads. The values of TVB-N, pH, PV and TBARS increased with time of storage. The results of TVB-N and microbial growth were in accordance with color change of beads and CIELab data. Therefore, the proposed system enjoys a high sensitivity to pH variations and is capable of monitoring the spoilage of fish or other protein-rich products through its wide range of color changes. The alginate beads containing the red cabbage extract can, thus, be used as a low-cost colorimetric sensor for intelligent packaging applications.

  17. Linear spin-wave theory of incommensurably modulated magnets

    DEFF Research Database (Denmark)

    Ziman, Timothy; Lindgård, Per-Anker

    1986-01-01

    Calculations of linearized theories of spin dynamics encounter difficulties when applied to incommensurable magnetic phases: lack of translational invariance leads to an infinite coupled system of equations. The authors resolve this for the case of a `single-Q' structure by mapping onto the problem......: at higher frequency there appear bands of response sharply defined in frequency, but broad in momentum transfer; at low frequencies there is a response maximum at the q vector corresponding to the modulation vector. They discuss generalizations necessary for application to rare-earth magnets...

  18. The control of beads diameter of bead-on-string electrospun nanofibers and the corresponding release behaviors of embedded drugs

    Energy Technology Data Exchange (ETDEWEB)

    Li, Tingxiao [Key Laboratory of Textile Science and Technology (Donghua University), Ministry of Education of China, Shanghai 201620 (China); College of Textiles, Donghua University, Shanghai 201620 (China); Ding, Xin, E-mail: xding@dhu.edu.cn [Key Laboratory of Textile Science and Technology (Donghua University), Ministry of Education of China, Shanghai 201620 (China); College of Textiles, Donghua University, Shanghai 201620 (China); Tian, Lingling, E-mail: lingling_tian@nus.edu.sg [Center of Nanofibers & Nanotechnology, Department of Mechanical Engineering, National University of Singapore, 117576 (Singapore); Hu, Jiyong; Yang, Xudong [Key Laboratory of Textile Science and Technology (Donghua University), Ministry of Education of China, Shanghai 201620 (China); College of Textiles, Donghua University, Shanghai 201620 (China); Ramakrishna, Seeram [Center of Nanofibers & Nanotechnology, Department of Mechanical Engineering, National University of Singapore, 117576 (Singapore); Guangdong-Hongkong-Macau Institute of CNS Regeneration (GHMICR), Jinan University, Guangzhou 510632 (China)

    2017-05-01

    Bead-on-string nanofibers, with appropriate control of the beads diameter, are potential fibrous structures for efficient encapsulation of particle drugs in micron scales and could achieve controlled drug release for tissue engineering applications. In this study, the beads diameter of electrospun bead-on-string nanofibers was controlled by adjusting the concentration of spinning polymer, poly (lactic-co-glycolic acid) (PLGA), and the solvent ratio of chloroform to acetone. The images of the scanning electron microscopy (SEM) suggested that bead-on-string nanofibers could be successfully obtained only with a certain range of PLGA solution concentration. Moreover, with the decrease in the solvent ratio of chloroform to acetone, the range was left-shifted towards a smaller concentration. In addition, increase in the PLGA solution concentration within the range the beads diameter became greater and the shape of the beads changed from oval to slender when increasing the PLGA concentration within the range. The bead-on-string nanofibers with different beads diameter were further used to load micro-particle drugs of tetracycline hydrochloride, as a model drug, to examine the release behavior of nanofibers scaffold. The release profiles of drug loaded bead-on-string nanofibers demonstrated the possibility to alleviate the burst drug release by means of beads diameter control. - Highlights: • Bead diameter of bead-on-string electrospun nanofibers was controlled by varying solvent ratio and polymer concentration. • The effect of the addition of particle drugs on BD of bead-on-string electrospun nanofibers was studied. • The corresponding release behaviors of nanofibers with different BD loading micro-particle drugs were investigated. • Bead-on-string nanofibers with bigger BD could alleviate the initial burst release.

  19. The control of beads diameter of bead-on-string electrospun nanofibers and the corresponding release behaviors of embedded drugs

    International Nuclear Information System (INIS)

    Li, Tingxiao; Ding, Xin; Tian, Lingling; Hu, Jiyong; Yang, Xudong; Ramakrishna, Seeram

    2017-01-01

    Bead-on-string nanofibers, with appropriate control of the beads diameter, are potential fibrous structures for efficient encapsulation of particle drugs in micron scales and could achieve controlled drug release for tissue engineering applications. In this study, the beads diameter of electrospun bead-on-string nanofibers was controlled by adjusting the concentration of spinning polymer, poly (lactic-co-glycolic acid) (PLGA), and the solvent ratio of chloroform to acetone. The images of the scanning electron microscopy (SEM) suggested that bead-on-string nanofibers could be successfully obtained only with a certain range of PLGA solution concentration. Moreover, with the decrease in the solvent ratio of chloroform to acetone, the range was left-shifted towards a smaller concentration. In addition, increase in the PLGA solution concentration within the range the beads diameter became greater and the shape of the beads changed from oval to slender when increasing the PLGA concentration within the range. The bead-on-string nanofibers with different beads diameter were further used to load micro-particle drugs of tetracycline hydrochloride, as a model drug, to examine the release behavior of nanofibers scaffold. The release profiles of drug loaded bead-on-string nanofibers demonstrated the possibility to alleviate the burst drug release by means of beads diameter control. - Highlights: • Bead diameter of bead-on-string electrospun nanofibers was controlled by varying solvent ratio and polymer concentration. • The effect of the addition of particle drugs on BD of bead-on-string electrospun nanofibers was studied. • The corresponding release behaviors of nanofibers with different BD loading micro-particle drugs were investigated. • Bead-on-string nanofibers with bigger BD could alleviate the initial burst release.

  20. Linear Optical Response of Silicon Nanotubes Under Axial Magnetic Field

    Science.gov (United States)

    Chegel, Raad; Behzad, Somayeh

    2013-01-01

    We investigated the optical properties of silicon nanotubes (SiNTs) in the low energy region, E < 0.5 eV, and middle energy region, 1.8 eV < E < 2 eV. The dependence of optical matrix elements and linear susceptibility on radius and magnetic field, in terms of one-dimensional (1-d) wavevector and subband index, is calculated using the tight-binding approximation. It is found that, on increasing the nanotube diameter, the low-energy peaks show red-shift and their intensities are decreased. Also, we found that in the middle energy region all tubes have two distinct peaks, where the energy position of the second peak is approximately constant and independent of the nanotube diameter. Comparing the band structure of these tubes in different magnetic fields, several differences are clearly seen, such as splitting of degenerate bands, creation of additional band-edge states, and bandgap modification. It is found that applying the magnetic field leads to a phase transition in zigzag silicon hexagonal nanotubes (Si h-NTs), unlike in zigzag silicon gear-like nanotubes (Si g-NTs), which remain semiconducting in any magnetic field. We found that the axial magnetic field has two effects on the linear susceptibility spectrum, namely broadening and splitting. The axial magnetic field leads to the creation of a peak with energy less than 0.2 eV in metallic Si h-NTs, whereas in the absence of a magnetic field such a transition is not allowed.

  1. Fused Bead Analysis of Diogenite Meteorites

    Science.gov (United States)

    Mittlefehldt, D.W.; Beck, B.W.; McSween, H.Y.; Lee, C.T. A.

    2009-01-01

    Bulk rock chemistry is an essential dataset in meteoritics and planetary science [1]. A common method used to obtain the bulk chemistry of meteorites is ICP-MS. While the accuracy, precision and low detection limits of this process are advantageous [2], the sample size used for analysis (approx.70 mg) can be a problem in a field where small and finite samples are the norm. Fused bead analysis is another bulk rock analytical technique that has been used in meteoritics [3]. This technique involves forming a glass bead from 10 mg of sample and measuring its chemistry using a defocused beam on a microprobe. Though the ICP-MS has lower detection limits than the microprobe, the fused bead method destroys a much smaller sample of the meteorite. Fused bead analysis was initially designed for samples with near-eutectic compositions and low viscosities. Melts generated of this type homogenize at relatively low temperatures and produce primary melts near the sample s bulk composition [3]. The application of fused bead analysis to samples with noneutectic melt compositions has not been validated. The purpose of this study is to test if fused bead analysis can accurately determine the bulk rock chemistry of non-eutectic melt composition meteorites. To determine this, we conduct two examinations of the fused bead. First, we compare ICP-MS and fused bead results of the same samples using statistical analysis. Secondly, we inspect the beads for the presence of crystals and chemical heterogeneity. The presence of either of these would indicate incomplete melting and quenching of the bead.

  2. Method for regenerating magnetic polyamine-epichlorohydrin resin

    Science.gov (United States)

    Kochen, Robert L.; Navratil, James D.

    1997-07-29

    Magnetic polymer resins capable of efficient removal of actinides and heavy metals from contaminated water are disclosed together with methods for making, using, and regenerating them. The resins comprise polyamine-epichlorohydrin resin beads with ferrites attached to the surfaces of the beads. Markedly improved water decontamination is demonstrated using these magnetic polymer resins of the invention in the presence of a magnetic field, as compared with water decontamination methods employing ordinary ion exchange resins or ferrites taken separately.

  3. Design and testing of a coaxial linear magnetic spring with integral linear motor. [for spacecraft energy storage

    Science.gov (United States)

    Patt, P. J.

    1985-01-01

    The design of a coaxial linear magnetic spring which incorporates a linear motor to control axial motion and overcome system damping is presented, and the results of static and dynamic tests are reported. The system has nominal stiffness 25,000 N/m and is designed to oscillate a 900-g component over a 4.6-mm stroke in a Stirling-cycle cryogenic refrigerator being developed for long-service (5-10-yr) space applications (Stolfi et al., 1983). Mosaics of 10 radially magnetized high-coercivity SmCO5 segments enclosed in Ti cans are employed, and the device is found to have quality factor 70-100, corresponding to energy-storage efficiency 91-94 percent. Drawings, diagrams, and graphs are provided.

  4. Construction and characterisation of a modular microfluidic system: coupling magnetic capture and electrochemical detection

    DEFF Research Database (Denmark)

    Godino, N.; Snakenborg, Detlef; Kutter, Jörg Peter

    2010-01-01

    , and a polycarbonate base where permanent magnets are hosted; these parts are designed to fit so that wire bonding and encapsulation are avoided. This system can perform bioassays over the surface of magnetic beads and uses only 50 mu L of bead suspension per assay. Following detection, captured beads are released...

  5. Disposal of bead ion exchange resin wastes

    International Nuclear Information System (INIS)

    Gay, R.L.; Granthan, L.F.

    1985-01-01

    Bead ion exchange resin wastes are disposed of by a process which involves spray-drying a bead ion exchange resin waste in order to remove substantially all of the water present in such waste, including the water on the surface of the ion exchange resin beads and the water inside the ion exchange resin beads. The resulting dried ion exchange resin beads can then be solidified in a suitable solid matrix-forming material, such as a polymer, which solidifies to contain the dried ion exchange resin beads in a solid monolith suitable for disposal by burial or other conventional means

  6. Magnetic susceptibility characterisation of superparamagnetic microspheres

    Science.gov (United States)

    Grob, David Tim; Wise, Naomi; Oduwole, Olayinka; Sheard, Steve

    2018-04-01

    The separation of magnetic materials in microsystems using magnetophoresis has increased in popularity. The wide variety and availability of magnetic beads has fuelled this drive. It is important to know the magnetic characteristics of the microspheres in order to accurately use them in separation processes integrated on a lab-on-a-chip device. To investigate the magnetic susceptibility of magnetic microspheres, the magnetic responsiveness of three types of Dynabeads microspheres were tested using two different approaches. The magnetophoretic mobility of individual microspheres is studied using a particle tracking system and the magnetization of each type of Dynabeads microsphere is measured using SQUID relaxometry. The magnetic beads' susceptibility is obtained at four different applied magnetic fields in the range of 38-70 mT for both the mobility and SQUID measurements. The susceptibility values in both approaches show a consistent magnetic field dependence.

  7. The non-linear growth of the magnetic Rayleigh-Taylor instability

    Science.gov (United States)

    Carlyle, Jack; Hillier, Andrew

    2017-09-01

    This work examines the effect of the embedded magnetic field strength on the non-linear development of the magnetic Rayleigh-Taylor instability (RTI) (with a field-aligned interface) in an ideal gas close to the incompressible limit in three dimensions. Numerical experiments are conducted in a domain sufficiently large so as to allow the predicted critical modes to develop in a physically realistic manner. The ratio between gravity, which drives the instability in this case (as well as in several of the corresponding observations), and magnetic field strength is taken up to a ratio which accurately reflects that of observed astrophysical plasma, in order to allow comparison between the results of the simulations and the observational data which served as inspiration for this work. This study finds reduced non-linear growth of the rising bubbles of the RTI for stronger magnetic fields, and that this is directly due to the change in magnetic field strength, rather than the indirect effect of altering characteristic length scales with respect to domain size. By examining the growth of the falling spikes, the growth rate appears to be enhanced for the strongest magnetic field strengths, suggesting that rather than affecting the development of the system as a whole, increased magnetic field strengths in fact introduce an asymmetry to the system. Further investigation of this effect also revealed that the greater this asymmetry, the less efficiently the gravitational energy is released. By better understanding the under-studied regime of such a major phenomenon in astrophysics, deeper explanations for observations may be sought, and this work illustrates that the strength of magnetic fields in astrophysical plasmas influences observed RTI in subtle and complex ways.

  8. Study on Surface Modification of Glass Bead by a Block Copolymer Coupling Agent

    Institute of Scientific and Technical Information of China (English)

    LI Yin; ZHANG Bing; ZHOU Xiao-dong

    2008-01-01

    A tri-block copolymer coupling agent polystyrene biock-poly(n-butyl-acrylate)-block-poly(r-methacryloxypro pylt rimethoxysilane)(PS-b-PnBA-b-PMPS)was synthesized by atom transfer radical polymerization(ATRP),and its molecular structure was characterized by fourier-transform infrared spectra,hydrogen nuclear magnetic resonance and gel permeation chromatography.The glass bead was treated with the block copolymer coupling agent,and then studied by transmission electron microscopy.The result showed that strong interaction was formed between the block copolymer coupling agent and the surface of glass bead,and then the block of poly(n-butylacrylate)formed a layer of film on the surface.

  9. Synthesis and characterization of chitosan impregnated calcium alginate beads for removal of uranium from aquatic stream

    International Nuclear Information System (INIS)

    Singhal, R.K.; Basu, H.; Manisha, V.; Reddy, A.V.R.; Sawant, Manjiri; Kamane, Suman

    2015-01-01

    The present study was conducted to study the feasibility of chitosan impregnated calcium alginate beads (Cal-Alg-Chi) to sorb the excess uranium from the aquatic stream. Chitosan is a linear polysaccharide composed of randomly distributed β-(1-4)-linked D glucosamine (deacetylated unit) and N-acetyl-D-glucosamine (acetylated unit). The optimal composition of calcium alginate chitosan beads is 4 % (wt/vol) alginate gel having 5% loading of chitosan. The nature and morphology of pure and uranium sorbed calcium alginate chitosan beads were characterized by scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS), and attenuated total reflectance Fourier transform infrared spectroscopy (ATRFTIR). The results of batch sorption experiments suggest that Cal-Alg-Chi beads are very effective for removal of uranium in the pH range of 2.0-5.0 and sorption is more than 80 % in the concentration range of 1-100 mgL -1

  10. Analysis and experimental validation of an HTS linear synchronous propulsion prototype with HTS magnetic suspension

    International Nuclear Information System (INIS)

    Jin Jianxun; Zheng Luhai; Guo Youguang; Xu Wei; Zhu Jianguo

    2011-01-01

    An HTS linear synchronous propulsion prototype with an HTSLSM drive is developed. The feasibility of combining an HTSLSM with an HTS magnetic suspension system has been verified. Three different PMGs are studied by ECS method and experiment verification to obtain an optimal one. The prototype has been tested to obtain the performance and thrust characteristics of the HTSLSM. The measurement results benefit the optimal design and control scheme development for an HTSLSM. A high temperature superconducting (HTS) linear propulsion system composed of a single-sided HTS linear synchronous motor (HTSLSM) in its middle and HTS magnetic suspension sub-systems on both sides has been developed. The HTSLSM uses an HTS bulk magnet array on the moving secondary, and the field-trapped characteristics of the HTS bulk using different magnetized methods have been measured and compared to identify their magnetization capability. In order to generate a large levitation force for the system, three different types of permanent magnet guideways (PMGs) have been numerically analyzed and experimentally verified to obtain an optimal PMG. Based on comprehensive experimental prototype tests, the results show that the HTS linear propulsion system can run with stable magnetic suspension having a constant air-gap length, and the thrust characteristics versus the exciting current, working frequency and the air-gap length have also been obtained. This work forms the basis for developing a practical HTS linear propulsion system by using HTS bulks both for propulsion and suspension.

  11. Electrochemical enzyme sensor arrays for the detection of the biogenic amines histamine, putrescine and cadaverine using magnetic beads as immobilisation supports

    International Nuclear Information System (INIS)

    Leonardo, Sandra; Campàs, Mònica

    2016-01-01

    Electrochemical biosensors based on diamine oxidase (DAO) conjugated to magnetic beads (MBs) were developed for the detection of histamine (Hist), putrescine (Put) and cadaverine (Cad), the most relevant biogenic amines (BAs) related to food safety and quality. DAO-MBs were immobilised on Co(II)-phthalocyanine/carbon and Prussian Blue/carbon electrodes to obtain mono-enzymatic biosensors, and on Os-wired HRP-modified carbon electrodes to obtain bi-enzymatic biosensors. The three sensor have low working potentials (+0.4 V, −0.1 V and −0.05 V vs Ag/AgCl, respectively), a linear range of two orders of magnitude (from 0.01 to 1 mM BA), good reproducibility (variability lower than 10 %), high repeatability (up to 8 consecutive measurements), limits of detection in the µM concentration range for Hist and in the sub-µM concentration range for Put and Cad, and no response from possible interfering compounds. The DAO-MB conjugates display excellent long-term stability (at least 3 months). The biosensor has been applied to the determination of BAs in spiked and naturally-spoiled fish, demonstrating its suitability both as screening tool and for BAs quantification. The use of MBs as supports for enzyme immobilisation is advantageous because the resulting biosensors are simple, fast, stable, affordable, and can be integrated into array platforms. This makes them suitable for high-throughput analysis of BAs in the food industry. (author)

  12. Modelling and measurement of a moving magnet linear compressor performance

    International Nuclear Information System (INIS)

    Liang, Kun; Stone, Richard; Davies, Gareth; Dadd, Mike; Bailey, Paul

    2014-01-01

    A novel moving magnet linear compressor with clearance seals and flexure bearings has been designed and constructed. It is suitable for a refrigeration system with a compact heat exchanger, such as would be needed for CPU cooling. The performance of the compressor has been experimentally evaluated with nitrogen and a mathematical model has been developed to evaluate the performance of the linear compressor. The results from the compressor model and the measurements have been compared in terms of cylinder pressure, the ‘P–V’ loop, stroke, mass flow rate and shaft power. The cylinder pressure was not measured directly but was derived from the compressor dynamics and the motor magnetic force characteristics. The comparisons indicate that the compressor model is well validated and can be used to study the performance of this type of compressor, to help with design optimization and the identification of key parameters affecting the system transients. The electrical and thermodynamic losses were also investigated, particularly for the design point (stroke of 13 mm and pressure ratio of 3.0), since a full understanding of these can lead to an increase in compressor efficiency. - Highlights: • Model predictions of the performance of a novel moving magnet linear compressor. • Prototype linear compressor performance measurements using nitrogen. • Reconstruction of P–V loops using a model of the dynamics and electromagnetics. • Close agreement between the model and measurements for the P–V loops. • The design point motor efficiency was 74%, with potential improvements identified

  13. First-wall design limitations for linear magnetic fusion (LMF) reactors

    International Nuclear Information System (INIS)

    Gryczkowski, G.E.; Krakowski, R.A.; Steinhauer, L.C.; Zumdieck, J.

    1978-01-01

    One approach to the endloss problem in linear magnetic fusion (LMF) uses high magnetic field to reduce the required confinement time. This approach is limited by magnet stresses and bremsstrahlung heating of the first wall; the first-wall thermal-pulsing issue is addressed. Pertinent thermophysical parameters are developed in the context of high-field LMF to identify promising first-wall materials, and thermal fatigue experiments relevant to LMF first walls are reviewed. High-flux first-wall concepts are described which include both solid and evaporating first-wall configurations

  14. Sandwich immunoassay for alpha-fetoprotein in human sera using gold nanoparticle and magnetic bead labels along with resonance Rayleigh scattering readout

    International Nuclear Information System (INIS)

    Lu, Yao; Huang, Xiangyi; Ren, Jicun

    2013-01-01

    We describe a sensitive sandwich immunoassay for alpha-fetoprotein (AFP). It is making use of gold nanoparticles (GNPs) and magnetic beads (MBs) as labels, and of resonance Rayleigh scattering for detection. Two antibodies were labeled with GNPs and MBs, respectively, and MB-antigen-GNP complexes were formed in the presence of antigens. The MB labels also serve as solid phase carriers that can be used to magnetically separate the immuno complex. The GNP labels are used as optical probes, and Rayleigh scattering was used to determine the concentration of free GNPs-antibody after separation of the MB-antigen-GNP complexes. The concentration of AFP is related to the intensity of light scattered by free GNPs in the 13.6 pM to 436 pM concentration range, and the limit of detection is 13.6 pM. The method was applied to the determination of AFP in sera of cancer patients, and the results agree well with those obtained by conventional ELISA. (author)

  15. Linear stability analysis of a levitated nanomagnet in a static magnetic field: Quantum spin stabilized magnetic levitation

    Science.gov (United States)

    Rusconi, C. C.; Pöchhacker, V.; Cirac, J. I.; Romero-Isart, O.

    2017-10-01

    We theoretically study the levitation of a single magnetic domain nanosphere in an external static magnetic field. We show that, apart from the stability provided by the mechanical rotation of the nanomagnet (as in the classical Levitron), the quantum spin origin of its magnetization provides two additional mechanisms to stably levitate the system. Despite the Earnshaw theorem, such stable phases are present even in the absence of mechanical rotation. For large magnetic fields, the Larmor precession of the quantum magnetic moment stabilizes the system in full analogy with magnetic trapping of a neutral atom. For low magnetic fields, the magnetic anisotropy stabilizes the system via the Einstein-de Haas effect. These results are obtained with a linear stability analysis of a single magnetic domain rigid nanosphere with uniaxial anisotropy in a Ioffe-Pritchard magnetic field.

  16. Quantitative determination of glycine in aqueous solution using glutamate dehydrogenase-immobilized glyoxal agarose beads.

    Science.gov (United States)

    Keskin, Semra Yilmazer; Keskin, Can Serkan

    2014-01-01

    In this study, an enzymatic procedure for the determination of glycine (Gly) was developed by using a column containing immobilized glutamate dehydrogenase (GDH) on glyoxal agarose beads. Ammonia is produced from the enzymatic reactions between Gly and GDH with NAD(+) in phosphate buffer medium. The indophenol blue method was used for ammonia detection based on the spectrophotometric measurements of blue-colored product absorbing at 640 nm. The calibration graph is linear in the range of 0.1-10 mM of Gly concentrations. The effect of pH, temperature, and time interval was studied to find column stability, and also the interference effects of other amino acids was investigated. The interaction between GDH and glyoxal agarose beads was analyzed by Fourier transform infrared (FTIR) spectroscopy. The morphology of the immobilized and non-immobilized agarose beads were characterized by atomic force microscopy (AFM).

  17. Magnetic microbead detection using the planar Hall effect

    International Nuclear Information System (INIS)

    Ejsing, Louise; Hansen, Mikkel F.; Menon, Aric K.; Ferreira, Hugo A.; Graham, Daniel L.; Freitas, Paulo P.

    2005-01-01

    Magnetic sensors based on the planar Hall effect of exchanged-biased permalloy have been fabricated and characterized. It is demonstrated that the sensors are feasible for detecting just a few commercial 2.0 μm magnetic beads commonly used for bioseparation (Micromer-M, Micromod, Germany) and that the sensor sense current is sufficient to generate a signal from the beads

  18. Ketorolac tromethamine floating beads for oral application: Characterization and in vitro/in vivo evaluation

    Science.gov (United States)

    Abou el Ela, Amal El Sayeh F.; Hassan, Maha A.; El- Maraghy, Dalia A.

    2013-01-01

    The floating beads have been employed to make a sustained release of the drug in the stomach and to decrease the dose of the drug and hence overcome its side effects. The common benefits of the floating beads were it is easy preparation, without the need of a high temperature, and high percentage of the drug entrapment. In the present work, the Ketorolac tromethamine (KT) floating beads were prepared by extrusion congealing method utilizing calcium carbonate as a gas forming agent. The physical characters of the produced beads were investigated such as KT yield, KT loading, and entrapment efficiency of the drug. In addition, floating behavior, swelling, particle size, morphology and KT stability were also evaluated. In vitro drug release study was carried out, and the kinetics of the release was evaluated using the linear regression method. Furthermore, the in vivo analgesic effect of KT after oral administration of the selected formula of floating beads (F10) was carried out using hot plate and tail flick methods. Oral commercial KT tablets and KT solution were used for the comparison. The prepared beads remained floated for more than 8 h. The optimized formulation (F10) exhibited prolonged drug release (more than 8 h) and the drug release follows the Higuchi kinetic model, with a Fickian diffusion mechanism according to Korsmeyer-Peppas (n = 0.466). Moreover, F10 showed a sustained analgesic effect as compared to the commercial tablet. PMID:25161380

  19. Quasi-linear landau kinetic equations for magnetized plasmas: compact propagator formalism, rotation matrices and interaction

    International Nuclear Information System (INIS)

    Misguich, J.H.

    2004-04-01

    As a first step toward a nonlinear renormalized description of turbulence phenomena in magnetized plasmas, the lowest order quasi-linear description is presented here from a unified point of view for collisionless as well as for collisional plasmas in a constant magnetic field. The quasi-linear approximation is applied to a general kinetic equation obtained previously from the Klimontovich exact equation, by means of a generalised Dupree-Weinstock method. The so-obtained quasi-linear description of electromagnetic turbulence in a magnetoplasma is applied to three separate physical cases: -) weak electrostatic turbulence, -) purely magnetic field fluctuations (the classical quasi-linear results are obtained for cosmic ray diffusion in the 'slab model' of magnetostatic turbulence in the solar wind), and -) collisional kinetic equations of magnetized plasmas. This mathematical technique has allowed us to derive basic kinetic equations for turbulent plasmas and collisional plasmas, respectively in the quasi-linear and Landau approximation. In presence of a magnetic field we have shown that the systematic use of rotation matrices describing the helical particle motion allows for a much more compact derivation than usually performed. Moreover, from the formal analogy between turbulent and collisional plasmas, the results derived here in detail for the turbulent plasmas, can be immediately translated to obtain explicit results for the Landau kinetic equation

  20. Quasi-linear landau kinetic equations for magnetized plasmas: compact propagator formalism, rotation matrices and interaction

    Energy Technology Data Exchange (ETDEWEB)

    Misguich, J.H

    2004-04-01

    As a first step toward a nonlinear renormalized description of turbulence phenomena in magnetized plasmas, the lowest order quasi-linear description is presented here from a unified point of view for collisionless as well as for collisional plasmas in a constant magnetic field. The quasi-linear approximation is applied to a general kinetic equation obtained previously from the Klimontovich exact equation, by means of a generalised Dupree-Weinstock method. The so-obtained quasi-linear description of electromagnetic turbulence in a magnetoplasma is applied to three separate physical cases: -) weak electrostatic turbulence, -) purely magnetic field fluctuations (the classical quasi-linear results are obtained for cosmic ray diffusion in the 'slab model' of magnetostatic turbulence in the solar wind), and -) collisional kinetic equations of magnetized plasmas. This mathematical technique has allowed us to derive basic kinetic equations for turbulent plasmas and collisional plasmas, respectively in the quasi-linear and Landau approximation. In presence of a magnetic field we have shown that the systematic use of rotation matrices describing the helical particle motion allows for a much more compact derivation than usually performed. Moreover, from the formal analogy between turbulent and collisional plasmas, the results derived here in detail for the turbulent plasmas, can be immediately translated to obtain explicit results for the Landau kinetic equation.

  1. An analogy of a magnetic mirror in mechanics

    International Nuclear Information System (INIS)

    Lal, Amit; Badiger, Shrikrishna M

    2005-01-01

    The motion of a charged particle in a magnetic mirror device is compared to the motion of a bead spiralling into a smooth hollow cone. The complete solution of the motion of the bead is derived and physical aspects of the solution obtained are discussed. Similarities between the motion of the bead and that of a charged particle in a magnetic mirror device are pointed out. The effort is primarily aimed at enhancing the physical understanding of the mechanics of a charged particle in a magnetic mirror device and secondarily at proposing an equivalent mechanics problem, devoid of any electro-dynamical aspect but still possessing all the interesting features of the original problem. The proposed problem can be taught at upper-division undergraduate level

  2. Effect of Heat Input on Geometry of Austenitic Stainless Steel Weld Bead on Low Carbon Steel

    Science.gov (United States)

    Saha, Manas Kumar; Hazra, Ritesh; Mondal, Ajit; Das, Santanu

    2018-05-01

    Among different weld cladding processes, gas metal arc welding (GMAW) cladding becomes a cost effective, user friendly, versatile method for protecting the surface of relatively lower grade structural steels from corrosion and/or erosion wear by depositing high grade stainless steels onto them. The quality of cladding largely depends upon the bead geometry of the weldment deposited. Weld bead geometry parameters, like bead width, reinforcement height, depth of penetration, and ratios like reinforcement form factor (RFF) and penetration shape factor (PSF) determine the quality of the weld bead geometry. Various process parameters of gas metal arc welding like heat input, current, voltage, arc travel speed, mode of metal transfer, etc. influence formation of bead geometry. In the current experimental investigation, austenite stainless steel (316) weld beads are formed on low alloy structural steel (E350) by GMAW using 100% CO2 as the shielding gas. Different combinations of current, voltage and arc travel speed are chosen so that heat input increases from 0.35 to 0.75 kJ/mm. Nine number of weld beads are deposited and replicated twice. The observations show that weld bead width increases linearly with increase in heat input, whereas reinforcement height and depth of penetration do not increase with increase in heat input. Regression analysis is done to establish the relationship between heat input and different geometrical parameters of weld bead. The regression models developed agrees well with the experimental data. Within the domain of the present experiment, it is observed that at higher heat input, the weld bead gets wider having little change in penetration and reinforcement; therefore, higher heat input may be recommended for austenitic stainless steel cladding on low alloy steel.

  3. Direct friction measurement in draw bead testing

    DEFF Research Database (Denmark)

    Olsson, David Dam; Bay, Niels; Andreasen, Jan Lasson

    2005-01-01

    The application of draw beads in sheet metal stamping ensures controlled drawing-in of flange parts. Lubrication conditions in draw beads are severe due to sliding under simultaneous bending. Based on the original draw bead test design by Nine [1] comprehensive studies of friction in draw beads...... have been reported in literature. A major drawback in all these studies is that friction is not directly measured, but requires repeated measurements of the drawing force with and without relative sliding between the draw beads and the sheet material. This implies two tests with a fixed draw bead tool...... and a freely rotating tool respectively, an approach, which inevitably implies large uncertainties due to scatter in the experimental conditions. In order to avoid this problem a new draw bead test is proposed by the authors measuring the friction force acting on the tool radius directly by a build...

  4. Beads from Inhumation Rite Burials of Gnezdovo Burial Mound

    Directory of Open Access Journals (Sweden)

    Dobrova Olga P.

    2017-12-01

    Full Text Available The beads from 33 inhumation burials at Gnezdovo burial mound are examined in the article. The beads (total 367 were crafted from stretched tube (258, stretched stick (3, winding (45, press molding (2 pcs., welding (2 pcs., and mosaic beads (9 pcs.. The burial mound contains virtually no broken beads, including the settlement's most common yellow glass beads. Besides glass beads, cornelian, crystal, amber and faience beads have been registered among the burial mound material, as well as beads crafted with metal. Apart from beads, grave inventories contained a series of pendants with a bead strung on a wire ring. The considered complexes contain five pendants of this type. Besides Gnezdovo, similar pendants have been discovered in Kiev, Timerev, Pskov and Vladimir barrows. A comparison between bead sets from Gnezdovo and Kiev burial mounds allows to conclude that the general composition and occurrence frequency of beads is identical for these burials. At the same time, beads crafted with rock crystal, cornelian and metal are more frequently discovered in Kiev inhumations.

  5. A String of Beads

    Science.gov (United States)

    Mead, Kelly C.

    2006-01-01

    In this article, the author relates how she designed a math activity she called Beads to use in conjunction with their school's 100th day celebration. Beads has provided her kindergarten class with many opportunities to practice a variety of math skills - counting, patterning, sorting, comparing, making sets, predicting, identifying numerals,…

  6. Particles Sorting in Micro Channel Using Designed Micro Electromagnets of Magnetic Field Gradient

    International Nuclear Information System (INIS)

    Chung, Yung-Chiang; Wu, Chen-Ming; Lin, Shih-Hao

    2016-01-01

    In this study, microelectromagnet, microchannel, syringe pump, and controlling devices were integrated to form a particle sorting system. A simple, two-dimensional, relatively quick fabricating and easily operating microelectromagnet was designed. Polystyrene particles and magnetic beads were pumped into the microchannel with the syringe pump, and it was observed that the magnetic beads were attracted to one of two outlets by the microelectromagnet, which features a gradually changing magnetic field. The polystyrene particles would move to another outlet because of different-width micro channel, and it completed the separation of the particles. Based on experimental results, the magnetic flux density of the microelectromagnet was 2.3 Gauss for a 12.5-μm average distance between electrodes at 1.0-μm increments, and the magnetic force was 0.22 pN for 2.8-μm magnetic beads. The separating rate was greater for larger distance increment and smaller average distance between the electrodes. The separating rate of the magnetic beads increased as the electric current increased and flow velocity decreased. When the flow velocity was 0.333 μm/s and electric current was 1 A, the separating rate was 90%. The separating rate of the polystyrene particles increased as the flow velocity increased and was 85% when the flow velocity was 0.6 μm/s. These results demonstrate that this particle sorting system has potential applications in bio-molecular studies. - Highlights: • We proposed a method for separating polystyrene particles and magnetic beads by the different-width outlets and microelectromagnet with gradually changing magnetic field, which is simple, two-dimensional and easily operating. • The separating rate was greater for larger distance increment and smaller average distance between the electrodes. • The separating rate of the magnetic beads increased as the electric current increased and flow velocity decreased, and the maximum value is 90%.

  7. Influence of magnetic flutter on tearing growth in linear and nonlinear theory

    Science.gov (United States)

    Kreifels, L.; Hornsby, W. A.; Weikl, A.; Peeters, A. G.

    2018-06-01

    Recent simulations of tearing modes in turbulent regimes show an unexpected enhancement in the growth rate. In this paper the effect is investigated analytically. The enhancement is linked to the influence of turbulent magnetic flutter, which is modelled by diffusion terms in magnetohydrodynamics (MHD) momentum balance and Ohm’s law. Expressions for the linear growth rate as well as the island width in nonlinear theory for small amplitudes are derived. The results indicate an enhanced linear growth rate and a larger linear layer width compared with resistive MHD. Also the island width in the nonlinear regime grows faster in the diffusive model. These observations correspond well to simulations in which the effect of turbulence on the magnetic island width and tearing mode growth is analyzed.

  8. Imaging based agglutination measurement of magnetic micro-particles on a lab-on-a-disk platform

    DEFF Research Database (Denmark)

    Wantiya, P.; Burger, Robert; Alstrøm, Tommy Sonne

    2014-01-01

    In this work we present a magnetic micro beads based agglutination assay on a centrifugal microfluidic platform. An imaging based method is used to quantify bead agglutination and measure the concentration of antibodies or C-reactive protein in solution.......In this work we present a magnetic micro beads based agglutination assay on a centrifugal microfluidic platform. An imaging based method is used to quantify bead agglutination and measure the concentration of antibodies or C-reactive protein in solution....

  9. Improvement of the dynamic performance of an AC linear permanent magnet machine

    NARCIS (Netherlands)

    Jansen, J.W.; Lomonova, E.; Vandenput, A.J.A.; Compter, J.C.; Verweij, A.H.

    2003-01-01

    This paper discusses the controller design and test approaches leading to the performance improvement of a brushless 3-phase AC synchronous permanent magnet linear machine. The feasible controller design concept for the linear machine is presented and further implemented in Simulink and dSPACE. Two

  10. Computation of magnetic field in DC brushless linear motors built with NdFeB magnets

    International Nuclear Information System (INIS)

    Basak, A.; Shirkoohi, G.H.

    1990-01-01

    A software package based on finite element technique has been used to compute three-dimensional magnetic fields and static forces developed in brushless d.c. linear motors. As the field flux-source two different types of permanent magnets, one of them being the high energy neodymium- iron-boron type, has been used in computer models. Motors with the same specifications as the computer models were built and experimental results obtained from them are compared with the computed results

  11. Microstructural Study on Oxygen Permeated Arc Beads

    Directory of Open Access Journals (Sweden)

    Kuan-Heng Liu

    2015-01-01

    Full Text Available We simulated short circuit of loaded copper wire at ambient atmosphere and successfully identified various phases of the arc bead. A cuprous oxide flake was formed on the surface of the arc bead in the rapid solidification process, and there were two microstructural constituents, namely, Cu-κ eutectic structure and solutal dendrites. Due to the arc bead formed at atmosphere during the local equilibrium solidification process, the phase of arc bead has segregated to the cuprous oxide flake, Cu-κ eutectic, and Cu phase solutal dendrites, which are the fingerprints of the arc bead permeated by oxygen.

  12. In-bead screening

    DEFF Research Database (Denmark)

    2013-01-01

    The present invention relates to screening of one-bead-one-compound (OBOC) combinatorial libraries which is useful for the discovery of compounds displaying molecular interactions with a biological or a physicochemical system, such as substrates and inhibitors of enzymes and the like. The invention...... provides a method for screening a library of compounds for their interaction with a physico- chemical or biological system and a corresponding kit for performing the method of screening a one-bead-one-compound library of compounds....

  13. A two-magnet strategy for improved mixing and capture from biofluids

    Science.gov (United States)

    Doyle, Andrew B.; Haselton, Frederick R.

    2016-01-01

    Magnetic beads are a popular method for concentrating biomolecules from solution and have been more recently used in multistep pre-arrayed microfluidic cartridges. Typical processing strategies rely on a single magnet, resulting in a tight cluster of beads and requiring long incubation times to achieve high capture efficiencies, especially in highly viscous patient samples. This report describes a two-magnet strategy to improve the interaction of the bead surface with the surrounding fluid inside of a pre-arrayed, self-contained assay-in-a-tube. In the two-magnet system, target biomarker capture occurs at a rate three times faster than the single-magnet system. In clinically relevant biomatrices, we find a 2.5-fold improvement in biomarker capture at lower sample viscosities with the two-magnet system. In addition, we observe a 20% increase in the amount of protein captured at high viscosity for the two-magnet configuration relative to the single magnet approach. The two-magnet approach offers a means to achieve higher biomolecule extraction yields and shorter assay times in magnetic capture assays and in self-contained processor designs. PMID:27158286

  14. Towards Hypoxia-responsive Drug-eluting Embolization Beads.

    Science.gov (United States)

    Ashrafi, Koorosh; Heaysman, Clare L; Phillips, Gary J; Lloyd, Andrew W; Lewis, Andrew L

    2017-05-30

    Drug release from chemoembolization microspheres stimulated by the presence of a chemically reducing environment may provide benefits for targeting drug resistant and metastatic hypoxic tumours. A water-soluble disulfide-based bifunctional cross-linker bis(acryloyl)-(l)-cystine (BALC) was synthesised, characterised and incorporated into a modified poly(vinyl) alcohol (PVA) hydrogel beads at varying concentrations using reverse suspension polymerisation. The beads were characterised to confirm the amount of cross-linker within each formulation and its effects on the bead properties. Elemental and UV/visible spectroscopic analysis confirmed the incorporation of BALC within the beads and sizing studies showed that in the presence of a reducing agent, all bead formulations increased in mean diameter. The BALC beads could be loaded with doxorubicin hydrochloride and amounts in excess of 300mg of drug per mL of hydrated beads could be achieved but required conversion of the carboxylic acid groups of the BALC to their sodium carboxylate salt forms. Elution of doxorubicin from the beads demonstrated a controlled release via ionic exchange. Some formulations exhibited an increase in size and release of drug in the presence of a reducing agent, and therefore demonstrated the ability to respond to an in vitro reducing environment. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  15. Serum protein profiling and proteomics in autistic spectrum disorder using magnetic bead-assisted mass spectrometry.

    Science.gov (United States)

    Taurines, Regina; Dudley, Edward; Conner, Alexander C; Grassl, Julia; Jans, Thomas; Guderian, Frank; Mehler-Wex, Claudia; Warnke, Andreas; Gerlach, Manfred; Thome, Johannes

    2010-04-01

    The pathophysiology of autistic spectrum disorder (ASD) is not fully understood and there are no diagnostic or predictive biomarkers. Proteomic profiling has been used in the past for biomarker research in several non-psychiatric and psychiatric disorders and could provide new insights, potentially presenting a useful tool for generating such biomarkers in autism. Serum protein pre-fractionation with C8-magnetic beads and protein profiling by matrix-assisted laser desorption/ionisation-time of flight-mass spectrometry (MALDI-ToF-MS) were used to identify possible differences in protein profiles in patients and controls. Serum was obtained from 16 patients (aged 8-18) and age-matched controls. Three peaks in the MALDI-ToF-MS significantly differentiated the ASD sample from the control group. Sub-grouping the ASD patients into children with and without comorbid Attention Deficit and Hyperactivity Disorder, ADHD (ASD/ADHD+ patients, n = 9; ASD/ADHD- patients, n = 7), one peak distinguished the ASD/ADHD+ patients from controls and ASD/ADHD- patients. Our results suggest that altered protein levels in peripheral blood of patients with ASD might represent useful biomarkers for this devastating psychiatric disorder.

  16. Adjustable Permanent Quadrupoles Using Rotating Magnet Material Rods for the Next Linear Collider.

    CERN Document Server

    Spencer, C M

    2002-01-01

    The proposed Next Linear Collider (NLC) will require over 1400 adjustable quadrupoles between the main linacs' accelerator structures. These 12.7 mm bore quadrupoles will have a range of integrated strength from 0.6 to 132 Tesla, with a maximum gradient of 135 Tesla per meter, an adjustment range of +0 -20% and effective lengths from 324 mm to 972 mm. The magnetic center must remain stable to within 1 micrometer during the 20% adjustment. In an effort to reduce estimated costs and increase reliability, several designs using hybrid permanent magnets have been developed. All magnets have iron poles and use either Samarium Cobalt or Neodymium Iron to provide the magnetic fields. Two prototypes use rotating rods containing permanent magnetic material to vary the gradient. Gradient changes of 20% and center shifts of less than 20 microns have been measured. These data are compared to an equivalent electromagnet prototype. See High Reliability Prototype Quadrupole for the Next Linear Collider by C.E Rago, C.M SPENC...

  17. DC and AC linear magnetic field sensor based on glass coated amorphous microwires with Giant Magnetoimpedance

    International Nuclear Information System (INIS)

    García-Chocano, Víctor Manuel; García-Miquel, Héctor

    2015-01-01

    Giant Magnetoimpedance (GMI) effect has been studied in amorphous glass-coated microwires of composition (Fe 6 Co 94 ) 72.5 Si 12.5 B 15 . The impedance of a 1.5 cm length sample has been characterized by using constant AC currents in the range of 400 µA–4 mA at frequencies from 7 to 15 MHz and DC magnetic fields from −900 to 900 A/m. Double peak responses have been obtained, showing GMI ratios up to 107%. A linear magnetic field sensor for DC and AC field has been designed, using two microwires connected in series with a magnetic bias of 400 A/m with opposite direction in each microwire in order to obtain a linear response from ±70 (A/m) rms for AC magnetic field, and ±100 A/m for DC magnetic field. A closed loop feedback circuit has been implemented to extend the linear range to ±1 kA/m for DC magnetic field. - Highlights: • Giant Magneto Impedance phenomenon has been studied in amorphous microwires. • A combination of two microwires with a bias field has been developed to get a linear response. • An electronic circuit has been developed to obtain a sensor with a linear response. • A feedback coil have been added to increase the measurable range of the sensor

  18. Metal-Containing Polystyrene Beads as Standards for Mass Cytometry.

    Science.gov (United States)

    Abdelrahman, Ahmed I; Ornatsky, Olga; Bandura, Dmitry; Baranov, Vladimir; Kinach, Robert; Dai, Sheng; Thickett, Stuart C; Tanner, Scott; Winnik, Mitchell A

    2010-01-01

    We examine the suitability of metal-containing polystyrene beads for the calibration of a mass cytometer instrument, a single particle analyser based on an inductively coupled plasma ion source and a time of flight mass spectrometer. These metal-containing beads are also verified for their use as internal standards for this instrument. These beads were synthesized by multiple-stage dispersion polymerization with acrylic acid as a comonomer. Acrylic acid acts as a ligand to anchor the metal ions within the interior of the beads. Mass cytometry enabled the bead-by-bead measurement of the metal-content and determination of the metal-content distribution. Beads synthesized by dispersion polymerization that involved three stages were shown to have narrower bead-to-bead variation in their lanthanide content than beads synthesized by 2-stage dispersion polymerization. The beads exhibited insignificant release of their lanthanide content to aqueous solutions of different pHs over a period of six months. When mixed with KG1a or U937 cell lines, metal-containing polymer beads were shown not to affect the mass cytometry response to the metal content of element-tagged antibodies specifically attached to these cells.

  19. Determination of diffusion coefficients and diffusion characteristics for chlorferon and diethylthiophosphate in Ca-alginate gel beads.

    Science.gov (United States)

    Ha, Jiyeon; Engler, Cady R; Lee, Seung Jae

    2008-07-01

    Diffusion characteristics of chlorferon and diethylthiophosphate (DETP) in Ca-alginate gel beads were studied to assist in designing and operating bioreactor systems. Diffusion coefficients for chlorferon and DETP in Ca-alginate gel beads determined at conditions suitable for biodegradation studies were 2.70 x 10(-11) m(2)/s and 4.28 x 10(-11) m(2)/s, respectively. Diffusivities of chlorferon and DETP were influenced by several factors, including viscosity of the bulk solution, agitation speed, and the concentrations of diffusing substrate and immobilized cells. Diffusion coefficients increased with increasing agitation speed, probably due to poor mixing at low speed and some attrition of beads at high speeds. Diffusion coefficients also increased with decreasing substrate concentration. Increased cell concentration in the gel beads caused lower diffusivity. Theoretical models to predict diffusivities as a function of cell weight fraction overestimated the effective diffusivities for both chlorferon and DETP, but linear relations between effective diffusivity and cell weight fraction were derived from experimental data. Calcium-alginate gel beads with radii of 1.65-1.70 mm used in this study were not subject to diffusional limitations: external mass transfer resistances were negligible based on Biot number calculations and effectiveness factors indicated that internal mass transfer resistance was negligible. Therefore, the degradation rates of chlorferon and DETP inside Ca-alginate gel beads were reaction-limited. (c) 2007 Wiley Periodicals, Inc.

  20. Development and validation of a novel diagnostic test for human brucellosis using a glyco-engineered antigen coupled to magnetic beads.

    Directory of Open Access Journals (Sweden)

    Andrés E Ciocchini

    Full Text Available Brucellosis is a highly contagious zoonosis and still a major human health problem in endemic areas of the world. Although several diagnostic tools are available, most of them are difficult to implement especially in developing countries where complex health facilities are limited. Taking advantage of the identical structure and composition of the Brucella spp. and Yersinia enterocolitica O:9 O-polysaccharide, we explored the application of a recombinant Y. enterocolitica O:9-polysaccharide-protein conjugate (OAg-AcrA as a novel antigen for diagnosis of human brucellosis. We have developed and validated an indirect immunoassay using OAg-AcrA coupled to magnetic beads. OAg-AcrA was produced and purified with high yields in Y. enterocolitica O:9 cells co-expressing the oligosaccharyltransferase PglB and the protein acceptor AcrA of Campylobacter jejuni without the need for culturing Brucella. Expression of PglB and AcrA in Y. enterocolitica resulted in the transfer of the host O-polysaccharide from its lipid carrier to AcrA. To validate the assay and determine the cutoff values, a receiver-operating characteristic analysis was performed using a panel of characterized serum samples obtained from healthy individuals and patients of different clinical groups. Our results indicate that, using this assay, it is possible to detect infection caused by the three main human brucellosis agents (B. abortus, B. melitensis and B. suis and select different cutoff points to adjust sensitivity and specificity levels as needed. A cutoff value of 13.20% gave a sensitivity of 100% and a specificity of 98.57%, and a cutoff value of 16.15% resulted in a test sensitivity and specificity of 93.48% and 100%, respectively. The high diagnostic accuracy, low cost, reduced assay time and simplicity of this new glycoconjugate-magnetic beads assay makes it an attractive diagnostic tool for using not only in clinics and brucellosis reference laboratories but also in locations

  1. Development and Validation of a Novel Diagnostic Test for Human Brucellosis Using a Glyco-engineered Antigen Coupled to Magnetic Beads

    Science.gov (United States)

    Ciocchini, Andrés E.; Rey Serantes, Diego A.; Melli, Luciano J.; Iwashkiw, Jeremy A.; Deodato, Bettina; Wallach, Jorge; Feldman, Mario F.; Ugalde, Juan E.; Comerci, Diego J.

    2013-01-01

    Brucellosis is a highly contagious zoonosis and still a major human health problem in endemic areas of the world. Although several diagnostic tools are available, most of them are difficult to implement especially in developing countries where complex health facilities are limited. Taking advantage of the identical structure and composition of the Brucella spp. and Yersinia enterocolitica O:9 O-polysaccharide, we explored the application of a recombinant Y. enterocolitica O:9-polysaccharide-protein conjugate (OAg-AcrA) as a novel antigen for diagnosis of human brucellosis. We have developed and validated an indirect immunoassay using OAg-AcrA coupled to magnetic beads. OAg-AcrA was produced and purified with high yields in Y. enterocolitica O:9 cells co-expressing the oligosaccharyltransferase PglB and the protein acceptor AcrA of Campylobacter jejuni without the need for culturing Brucella. Expression of PglB and AcrA in Y. enterocolitica resulted in the transfer of the host O-polysaccharide from its lipid carrier to AcrA. To validate the assay and determine the cutoff values, a receiver-operating characteristic analysis was performed using a panel of characterized serum samples obtained from healthy individuals and patients of different clinical groups. Our results indicate that, using this assay, it is possible to detect infection caused by the three main human brucellosis agents (B. abortus, B. melitensis and B. suis) and select different cutoff points to adjust sensitivity and specificity levels as needed. A cutoff value of 13.20% gave a sensitivity of 100% and a specificity of 98.57%, and a cutoff value of 16.15% resulted in a test sensitivity and specificity of 93.48% and 100%, respectively. The high diagnostic accuracy, low cost, reduced assay time and simplicity of this new glycoconjugate-magnetic beads assay makes it an attractive diagnostic tool for using not only in clinics and brucellosis reference laboratories but also in locations with limited

  2. Reconnection Scaling Experiment (RSX): Magnetic Reconnection in Linear Geometry

    Science.gov (United States)

    Intrator, T.; Sovinec, C.; Begay, D.; Wurden, G.; Furno, I.; Werley, C.; Fisher, M.; Vermare, L.; Fienup, W.

    2001-10-01

    The linear Reconnection Scaling Experiment (RSX) at LANL is a new experiment that can create MHD relevant plasmas to look at the physics of magnetic reconnection. This experiment can scale many relevant parameters because the guns that generate the plasma and current channels do not depend on equilibrium or force balance for startup. We describe the experiment and initial electrostatic and magnetic probe data. Two parallel current channels sweep down a long plasma column and probe data accumulated over many shots gives 3D movies of magnetic reconnection. Our first data tries to define an operating regime free from kink instabilities that might otherwise confuse the data and shot repeatability. We compare this with MHD 2 fluid NIMROD simulations of the single current channel kink stability boundary for a variety of experimental conditions.

  3. General methods for determining the linear stability of coronal magnetic fields

    Science.gov (United States)

    Craig, I. J. D.; Sneyd, A. D.; Mcclymont, A. N.

    1988-01-01

    A time integration of a linearized plasma equation of motion has been performed to calculate the ideal linear stability of arbitrary three-dimensional magnetic fields. The convergence rates of the explicit and implicit power methods employed are speeded up by using sequences of cyclic shifts. Growth rates are obtained for Gold-Hoyle force-free equilibria, and the corkscrew-kink instability is found to be very weak.

  4. Lexan Linear Shaped Charge Holder with Magnets and Backing Plate

    Science.gov (United States)

    Maples, Matthew W.; Dutton, Maureen L.; Hacker, Scott C.; Dean, Richard J.; Kidd, Nicholas; Long, Chris; Hicks, Robert C.

    2013-01-01

    A method was developed for cutting a fabric structural member in an inflatable module, without damaging the internal structure of the module, using linear shaped charge. Lexan and magnets are used in a charge holder to precisely position the linear shaped charge over the desired cut area. Two types of charge holders have been designed, each with its own backing plate. One holder cuts fabric straps in the vertical configuration, and the other charge holder cuts fabric straps in the horizontal configuration.

  5. A Magnetic Sensor System for Biological Detection

    KAUST Repository

    Li, Fuquan

    2015-01-01

    Magnetic biosensors detect biological targets through sensing the stray field of magnetic beads which label the targets. Commonly, magnetic biosensors employ the “sandwich” method to immobilize biological targets, i.e., the targets are sandwiched

  6. The Beads of Translation: Using Beads to Translate mRNA into a Polypeptide Bracelet

    Science.gov (United States)

    Dunlap, Dacey; Patrick, Patricia

    2012-01-01

    During this activity, by making beaded bracelets that represent the steps of translation, students simulate the creation of an amino acid chain. They are given an mRNA sequence that they translate into a corresponding polypeptide chain (beads). This activity focuses on the events and sites of translation. The activity provides students with a…

  7. K Basin sludge/resin bead separation test report

    International Nuclear Information System (INIS)

    Squier, D.M.

    1998-01-01

    The K Basin sludge is an accumulation of fuel element corrosion products, organic and inorganic ion exchange materials, canister gasket materials, iron and aluminum corrosion products, sand, dirt and minor amounts of other organic material. The sludge will be collected and treated for storage and eventual disposal. This process will remove the large solid materials by a 1/4 inch screen. The screened material will be subjected to nitric acid in a chemical treatment process. The organic ion exchange resin beads produce undesirable chemical reactions with the nitric acid. The resin beads must be removed from the bulk material and treated by another process. An effective bead separation method must extract 95% of the resin bead mass without entraining more than 5% of the other sludge component mass. The test plan I-INF-2729, ''Organic Ion Exchange Resin Separation Methods Evaluation,'' proposed the evaluation of air lift, hydro cyclone, agitated slurry and elutriation resin bead separation methods. This follows the testing strategy outlined in section 4.1 of BNF-2574, ''Testing Strategy to Support the Development of K Basins Sludge Treatment Process''. Engineering study BNF-3128, ''Separation of Organic Ion Exchange Resins from Sludge,'' Rev. 0, focused the evaluation tests on a method that removed the fine sludge particles by a sieve and then extracted the beads by means of a elutriation column. Ninety-nine percent of the resin beads are larger than 125 microns and 98.5 percent are 300 microns and larger. Particles smaller than 125 microns make up the largest portion of sludge in the K Basins. Eliminating a large part of the sludge's non-bead component will reduce the quantity that is lifted with the resin beads in the elutriation column. Resin bead particle size distribution measurements are given in Appendix A The Engineering Testing Laboratory conducted measurements of a elutriation column's ability to extract resin beads from a sieved, non-radioactive sludge

  8. Force measurements on a shielded coreless linear permanent magnet motor

    NARCIS (Netherlands)

    Pluk, K.J.W.; Jansen, J.W.; Lomonova, E.A.

    2014-01-01

    This paper compares force measurements on a shielded coreless linear permanent magnet motor with 2-D models. A 2-D semianalytical modeling method is applied, which is based on Fourier modeling and includes force calculations. The semianalytical modeling correctly predicts the behavior found in the

  9. Stabilisation and precision pointing quadrupole magnets in the Compact Linear Collider (CLIC)

    CERN Document Server

    Janssens, Stef; Linde, Frank; van den Brand, Jo; Bertolini, Alessandro; Artoos, Kurt

    This thesis describes the research done to provide stabilisation and precision positioning for the main beam quadrupole magnets of the Compact Linear Collider CLIC. The introduction describes why new particle accelerators are needed to further the knowledge of our universe and why they are linear. A proposed future accelerator is the Compact Linear Collider (CLIC) which consists of a novel two beam accelerator concept. Due to its linearity and subsequent single pass at the interaction point, this new accelerator requires a very small beam size at the interaction point, in order to increase collision effectiveness. One of the technological challenges, to obtain these small beam sizes at the interaction point, is to keep the quadrupole magnets aligned and stable to 1.5 nm integrated r.m.s. in vertical and 5 nm integrated root mean square (r.m.s.) in lateral direction. Additionally there is a proposal to create an intentional offset (max. 50 nm every 20 ms with a precision of +/- 1 nm), for several quadrupole ma...

  10. Adjustable Permanent Quadrupoles Using Rotating Magnet Material Rods for the Next Linear Collider

    International Nuclear Information System (INIS)

    Spencer, Cherrill M

    2002-01-01

    The proposed Next Linear Collider (NLC) will require over 1400 adjustable quadrupoles between the main linacs' accelerator structures. These 12.7 mm bore quadrupoles will have a range of integrated strength from 0.6 to 132 Tesla, with a maximum gradient of 135 Tesla per meter, an adjustment range of +0 -20% and effective lengths from 324 mm to 972 mm. The magnetic center must remain stable to within 1 micrometer during the 20% adjustment. In an effort to reduce estimated costs and increase reliability, several designs using hybrid permanent magnets have been developed. All magnets have iron poles and use either Samarium Cobalt or Neodymium Iron to provide the magnetic fields. Two prototypes use rotating rods containing permanent magnetic material to vary the gradient. Gradient changes of 20% and center shifts of less than 20 microns have been measured. These data are compared to an equivalent electromagnet prototype. See High Reliability Prototype Quadrupole for the Next Linear Collider by C.E Rago, C.M SPENCER, Z. Wolf submitted to this conference

  11. On-bead fluorescent DNA nanoprobes to analyze base excision repair activities

    International Nuclear Information System (INIS)

    Gines, Guillaume; Saint-Pierre, Christine; Gasparutto, Didier

    2014-01-01

    Graphical abstract: -- Highlights: •On magnetic beads fluorescent enzymatic assays. •Simple, easy, non-radioactive and electrophoresis-free functional assay. •Lesion-containing hairpin DNA probes are selective for repair enzymes. •The biosensing platform allows the measurement of DNA repair activities from purified enzymes or within cell free extracts. -- Abstract: DNA integrity is constantly threatened by endogenous and exogenous agents that can modify its physical and chemical structure. Changes in DNA sequence can cause mutations sparked by some genetic diseases or cancers. Organisms have developed efficient defense mechanisms able to specifically repair each kind of lesion (alkylation, oxidation, single or double strand break, mismatch, etc). Here we report the adjustment of an original assay to detect enzymes’ activity of base excision repair (BER), that supports a set of lesions including abasic sites, alkylation, oxidation or deamination products of bases. The biosensor is characterized by a set of fluorescent hairpin-shaped nucleic acid probes supported on magnetic beads, each containing a selective lesion targeting a specific BER enzyme. We have studied the DNA glycosylase alkyl-adenine glycosylase (AAG) and the human AP-endonuclease (APE1) by incorporating within the DNA probe a hypoxanthine lesion or an abasic site analog (tetrahydrofuran), respectively. Enzymatic repair activity induces the formation of a nick in the damaged strand, leading to probe's break, that is detected in the supernatant by fluorescence. The functional assay allows the measurement of DNA repair activities from purified enzymes or in cell-free extracts in a fast, specific, quantitative and sensitive way, using only 1 pmol of probe for a test. We recorded a detection limit of 1 μg mL −1 and 50 μg mL −1 of HeLa nuclear extracts for APE1 and AAG enzymes, respectively. Finally, the on-bead assay should be useful to screen inhibitors of DNA repair activities

  12. Influence of heat input on weld bead geometry using duplex stainless steel wire electrode on low alloy steel specimens

    Directory of Open Access Journals (Sweden)

    Ajit Mondal

    2016-12-01

    Full Text Available Gas metal arc welding cladding becomes a popular surfacing technique in many modern industries as it enhances effectively corrosion resistance property and wear resistance property of structural members. Quality of weld cladding may be enhanced by controlling process parameters. If bead formation is found acceptable, cladding is also expected to be good. Weld bead characteristics are often assessed by bead geometry, and it is mainly influenced by heat input. In this paper, duplex stainless steel E2209 T01 is deposited on E250 low alloy steel specimens with 100% CO2 gas as shielding medium with different heats. Weld bead width, height of reinforcement and depth of penetration are measured. Regression analysis is done on the basis of experimental data. Results reveal that within the range of bead-on-plate welding experiments done, parameters of welding geometry are on the whole linearly related with heat input. A condition corresponding to 0.744 kJ/mm heat input is recommended to be used for weld cladding in practice.

  13. Development of an in situ magnetic beads based RT-PCR method for electrochemiluminescent detection of rotavirus

    Science.gov (United States)

    Zhan, Fangfang; Zhou, Xiaoming

    2012-12-01

    Rotaviruses are double-stranded RNA viruses belonging to the family of enteric pathogens. It is a major cause of diarrhoeal disease in infants and young children worldwide. Consequently, rapid and accurate detection of rotaviruses is of great importance in controlling and preventing food- and waterborne diseases and outbreaks. Reverse transcription-polymerase chain reaction (RT-PCR) is a reliable method that possesses high specificity and sensitivity. It has been widely used to detection of viruses. Electrochemiluminescence (ECL) can be considered as an important and powerful tool in analytical and clinical application with high sensitivity, excellent specificity, and low cost. Here we have developed a method for the detection of rotavirus by combining in situ magnetic beads (MBs) based RT-PCR with ECL. RT of rotavirus RNA was carried out in a traditional way and the resulting cDNA was directly amplified on MBs. Forward primers were covalently bounded to MBs and reverse primers were labeled with tris-(2, 2'-bipyridyl) ruthenium (TBR). During the PCR cycling, the TBR labeled products were directly loaded and enriched on the surface of MBs. Then the MBs-TBR complexes could be analyzed by a magnetic ECL platform without any post-modification or post-incubation which avoid some laborious manual operations and achieve rapid yet sensitive detection. In this study, rotavirus from fecal specimens was successfully detected within 2 h, and the limit of detection was estimated to be 104copies/μL. This novel in situ MBs based RT-PCR with ECL detection method can be used for pathogen detection in food safety field and clinical diagnosis.

  14. Sequential injection chemiluminescence immunoassay for nonionic surfactants by using magnetic microbeads

    International Nuclear Information System (INIS)

    Zhang Ruiq; Nakajima, Hizuru; Soh, Nobuaki; Nakano, Koji; Masadome, Takashi; Nagata, Kazumi; Sakamoto, Kazuhira; Imato, Toshihiko

    2007-01-01

    A rapid and sensitive immunoassay based on a sequential injection analysis (SIA) using magnetic microbeads for the determination of alkylphenol polyethoxylates (APnEOs) is described. An SIA system was constructed from a syringe pump, a switching valve, a flow-through type immunoreaction cell equipped with a photon counting unit and a neodymium magnet. Magnetic beads, to which an anti-APnEOs monoclonal antibody was immobilized, were used as a solid support in an immunoassay. The introduction, trapping and release of the magnetic beads in and from the immunoreaction cell were controlled by means of a neodymium magnet and adjusting the flow of a carrier solution. The immunoassay was based on an indirect competitive immunoreaction of an anti-APnEOs monoclonal antibody immobilized on the magnetic beads with a sample APnEOs and a horseradish peroxidase (HRP)-labeled APnEOs in the same sample solution, and was based on the subsequent chemiluminscence reaction of HRP on the magnetic microbeads with a luminol solution containing hydrogen peroxide and p-iodophenol. The anti-APnEOs antibody was immobilized on the magnetic microbeads by coupling the antibody with the magnetic beads after activation of a carboxylate moiety on the surface of the magnetic beads that had been coated with a polylactic acid film. The antibody immobilized magnetic beads were introduced in the immunoreaction cell and trapped in it by the neodymium magnet, which was equipped beneath the immunoreaction cell. An APnEOs sample solution containing the HRP-labeled APnEOs at a constant concentration, and a luminol solution containing hydrogen peroxide and p-iodophenol were sequentially introduced into the immunoreaction cell, according to an SIA programmed sequence. Chemiluminescence emission was monitored by means of a photon counting unit located at the upper side of the immunoreaction cell by collecting the emitted light with a lens. A typical sigmoidal calibration curve was obtained, when the logarithm

  15. Force analysis of linear induction motor for magnetic levitation system

    NARCIS (Netherlands)

    Kuijpers, A.A.; Nemlioglu, C.; Sahin, F.; Verdel, A.J.D.; Compter, J.C.; Lomonova, E.

    2010-01-01

    This paper presents the analyses of thrust and normal forces of linear induction motor (LIM) segments which are implemented in a rotating ring system. To obtain magnetic levitation in a cost effective and sustainable way, decoupled control of thrust and normal forces is required. This study includes

  16. DWPF GLASS BEADS AND GLASS FRIT TRANSPORT DEMONSTRATION

    Energy Technology Data Exchange (ETDEWEB)

    Adamson, D; Bradley Pickenheim, B

    2008-11-24

    DWPF is considering replacing irregularly shaped glass frit with spherical glass beads in the Slurry Mix Evaporator (SME) process to decrease the yield stress of the melter feed (a non-Newtonian Bingham Plastic). Pilot-scale testing was conducted on spherical glass beads and glass frit to determine how well the glass beads would transfer when compared to the glass frit. Process Engineering Development designed and constructed the test apparatus to aid in the understanding and impacts that spherical glass beads may have on the existing DWPF Frit Transfer System. Testing was conducted to determine if the lines would plug with the glass beads and the glass frit slurry and what is required to unplug the lines. The flow loop consisted of vertical and horizontal runs of clear PVC piping, similar in geometry to the existing system. Two different batches of glass slurry were tested: a batch of 50 wt% spherical glass beads and a batch of 50 wt% glass frit in process water. No chemicals such as formic acid was used in slurry, only water and glass formers. The glass beads used for this testing were commercially available borosilicate glass of mesh size -100+200. The glass frit was Frit 418 obtained from DWPF and is nominally -45+200 mesh. The spherical glass beads did not have a negative impact on the frit transfer system. The transferring of the spherical glass beads was much easier than the glass frit. It was difficult to create a plug with glass bead slurry in the pilot transfer system. When a small plug occurred from setting overnight with the spherical glass beads, the plug was easy to displace using only the pump. In the case of creating a man made plug in a vertical line, by filling the line with spherical glass beads and allowing the slurry to settle for days, the plug was easy to remove by using flush water. The glass frit proved to be much more difficult to transfer when compared to the spherical glass beads. The glass frit impacted the transfer system to the point

  17. DWPF GLASS BEADS AND GLASS FRIT TRANSPORT DEMONSTRATION

    International Nuclear Information System (INIS)

    Adamson, D.; Pickenheim, Bradley

    2008-01-01

    DWPF is considering replacing irregularly shaped glass frit with spherical glass beads in the Slurry Mix Evaporator (SME) process to decrease the yield stress of the melter feed (a non-Newtonian Bingham Plastic). Pilot-scale testing was conducted on spherical glass beads and glass frit to determine how well the glass beads would transfer when compared to the glass frit. Process Engineering Development designed and constructed the test apparatus to aid in the understanding and impacts that spherical glass beads may have on the existing DWPF Frit Transfer System. Testing was conducted to determine if the lines would plug with the glass beads and the glass frit slurry and what is required to unplug the lines. The flow loop consisted of vertical and horizontal runs of clear PVC piping, similar in geometry to the existing system. Two different batches of glass slurry were tested: a batch of 50 wt% spherical glass beads and a batch of 50 wt% glass frit in process water. No chemicals such as formic acid was used in slurry, only water and glass formers. The glass beads used for this testing were commercially available borosilicate glass of mesh size -100+200. The glass frit was Frit 418 obtained from DWPF and is nominally -45+200 mesh. The spherical glass beads did not have a negative impact on the frit transfer system. The transferring of the spherical glass beads was much easier than the glass frit. It was difficult to create a plug with glass bead slurry in the pilot transfer system. When a small plug occurred from setting overnight with the spherical glass beads, the plug was easy to displace using only the pump. In the case of creating a man made plug in a vertical line, by filling the line with spherical glass beads and allowing the slurry to settle for days, the plug was easy to remove by using flush water. The glass frit proved to be much more difficult to transfer when compared to the spherical glass beads. The glass frit impacted the transfer system to the point

  18. Criterion of magnetic saturation and simulation of nonlinear magnetization for a linear multi-core pulse transformer

    International Nuclear Information System (INIS)

    Zeng Zhengzhong; Kuai Bin; Sun Fengju; Cong Peitian; Qiu Aici

    2002-01-01

    The linear multi-core pulse transformer is an important primary driving source used in pulsed power apparatus for the production of dense plasm owing to its compact, relatively low-cost and easy-to-handle characteristics. The evaluation of the magnetic saturation of the transformer cores is essential to the transformer design, because the energy transfer efficiency of the transformer will degrade significantly after magnetic saturation. This work proposes analytical formulas of the criterion of magnetic saturation for the cores when the transformer drives practical loads. Furthermore, an electric circuit model based on a dependent source treatment for simulating the electric behavior of the cores related to their nonlinear magnetization is developed using the initial magnetization curve of the cores. The numerical simulation with the model is used to evaluate the validity of the criterion. Both the criterion and the model are found to be in agreement with the experimental data

  19. Stochastic field-line wandering in magnetic turbulence with shear. I. Quasi-linear theory

    Energy Technology Data Exchange (ETDEWEB)

    Shalchi, A. [Department of Physics and Astronomy, University of Manitoba, Winnipeg, Manitoba R3T 2N2 (Canada); Negrea, M.; Petrisor, I. [Department of Physics, University of Craiova, Association Euratom-MEdC, 13A.I.Cuza Str, 200585 Craiova (Romania)

    2016-07-15

    We investigate the random walk of magnetic field lines in magnetic turbulence with shear. In the first part of the series, we develop a quasi-linear theory in order to compute the diffusion coefficient of magnetic field lines. We derive general formulas for the diffusion coefficients in the different directions of space. We like to emphasize that we expect that quasi-linear theory is only valid if the so-called Kubo number is small. We consider two turbulence models as examples, namely, a noisy slab model as well as a Gaussian decorrelation model. For both models we compute the field line diffusion coefficients and we show how they depend on the aforementioned Kubo number as well as a shear parameter. It is demonstrated that the shear effect reduces all field line diffusion coefficients.

  20. Stochastic field-line wandering in magnetic turbulence with shear. I. Quasi-linear theory

    International Nuclear Information System (INIS)

    Shalchi, A.; Negrea, M.; Petrisor, I.

    2016-01-01

    We investigate the random walk of magnetic field lines in magnetic turbulence with shear. In the first part of the series, we develop a quasi-linear theory in order to compute the diffusion coefficient of magnetic field lines. We derive general formulas for the diffusion coefficients in the different directions of space. We like to emphasize that we expect that quasi-linear theory is only valid if the so-called Kubo number is small. We consider two turbulence models as examples, namely, a noisy slab model as well as a Gaussian decorrelation model. For both models we compute the field line diffusion coefficients and we show how they depend on the aforementioned Kubo number as well as a shear parameter. It is demonstrated that the shear effect reduces all field line diffusion coefficients.

  1. 3D Analytical Calculation of Forces between Linear Halbach-Type Permanent Magnet Arrays

    OpenAIRE

    Allag , Hicham; Yonnet , Jean-Paul; Latreche , Mohamed E. H.

    2009-01-01

    International audience; Usely, in analytical calculation of magnetic and mechanical quantities of Halbach systems, the authors use the Fourier series approximation because the exact calculations are more difficult. In this work the interaction forces between linear Halbach arrays are analytically calculated thanks to our recent development 3D exact calculation of forces between two cuboïdal magnets with parallel and perpendicular magnetization. We essentially describe the way to separately ca...

  2. Modelling of a linear PM machine including magnetic saturation and end effects : maximum force to current ratio

    NARCIS (Netherlands)

    Polinder, H.; Slootweg, J.G.; Hoeijmakers, M.J.; Compter, J.C.

    2003-01-01

    The use of linear permanent-magnet (PM) actuators increases in a wide variety of applications because of their high force density, robustness and accuracy. These linear PM motors are often heavily loaded during short intervals of high acceleration, so that magnetic saturation occurs. This paper

  3. Adsorption of arsenic by activated carbon, calcium alginate and their composite beads

    Czech Academy of Sciences Publication Activity Database

    Hassan, A F.; Abdel-Mohsen, A. M.; Elhadidy, Hassan

    2014-01-01

    Roč. 68, JUL (2014), s. 125-130 ISSN 0141-8130 R&D Projects: GA MŠk(CZ) ED1.1.00/02.0068; GA MŠk(CZ) EE2.3.20.0214 Institutional support: RVO:68081723 Keywords : Apricot stone * Alginate beads * Composite * Arsenic * Adsorption Subject RIV: BM - Solid Matter Physics ; Magnetism OBOR OECD: Condensed matter physics (including formerly solid state physics, supercond.) Impact factor: 2.858, year: 2014

  4. Energy efficient bead milling of microalgae: Effect of bead size on disintegration and release of proteins and carbohydrates.

    Science.gov (United States)

    Postma, P R; Suarez-Garcia, E; Safi, C; Yonathan, K; Olivieri, G; Barbosa, M J; Wijffels, R H; Eppink, M H M

    2017-01-01

    The disintegration of three industry relevant algae (Chlorella vulgaris, Neochloris oleoabundans and Tetraselmis suecica) was studied in a lab scale bead mill at different bead sizes (0.3-1mm). Cell disintegration, proteins and carbohydrates released into the water phase followed a first order kinetics. The process is selective towards proteins over carbohydrates during early stages of milling. In general, smaller beads led to higher kinetic rates, with a minimum specific energy consumption of ⩽0.47kWhkg DW -1 for 0.3mm beads. After analysis of the stress parameters (stress number and stress intensity), it appears that optimal disintegration and energy usage for all strains occurs in the 0.3-0.4mm range. During the course of bead milling, the native structure of the marker protein Rubisco was retained, confirming the mildness of the disruption process. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  5. Magnetic scanning gate microscopy of a domain wall nanosensor using microparticle probe

    Energy Technology Data Exchange (ETDEWEB)

    Corte-León, H., E-mail: hector.corte@npl.co.uk [National Physical Laboratory, Teddington TW11 0LW (United Kingdom); Royal Holloway University of London, Egham TW20 0EX (United Kingdom); Gribkov, B. [National Physical Laboratory, Teddington TW11 0LW (United Kingdom); Krzysteczko, P. [Physikalisch-Technische Bundesanstalt, Braunschweig D-38116 (Germany); Marchi, F.; Motte, J.-F. [University of Grenoble Alpes, Inst. NEEL, Grenoble F-38042 (France); CNRS, Inst. NEEL, Grenoble F-38042 (France); Schumacher, H.W. [Physikalisch-Technische Bundesanstalt, Braunschweig D-38116 (Germany); Antonov, V. [Royal Holloway University of London, Egham TW20 0EX (United Kingdom); Kazakova, O. [National Physical Laboratory, Teddington TW11 0LW (United Kingdom)

    2016-02-15

    We apply the magnetic scanning gate microscopy (SGM) technique to study the interaction between a magnetic bead (MB) and a domain wall (DW) trapped in an L-shaped magnetic nanostructure. Magnetic SGM is performed using a custom-made probe, comprising a hard magnetic NdFeB bead of diameter 1.6 µm attached to a standard silicon tip. The MB–DW interaction is detected by measuring changes in the electrical resistance of the device as a function of the tip position. By scanning at different heights, we create a 3D map of the MB–DW interaction and extract the sensing volume for different widths of the nanostructure's arms. It is shown that for 50 nm wide devices the sensing volume is a cone of 880 nm in diameter by 1.4 µm in height, and reduces down to 800 nm in height for 100 nm devices with almost no change in its diameter. - Highlights: • AFM tips with a magnetic bead attached used to test interaction with domain wall. • Domain wall inside a nanostructure affect the electrical resistance. • Recording electrical resistance while scanning with modified AFM probe. • Change of resistance as a function of the position of the magnetic bead. • This allows comparing different devices in a reproducible and controllable way.

  6. Optimal design of a double-sided linear motor with a multi-segmented trapezoidal magnet array for a high precision positioning system

    International Nuclear Information System (INIS)

    Lee, Moon G.; Gweon, Dae-Gab

    2004-01-01

    A comparative analysis is performed for linear motors adopting conventional and multi-segmented trapezoidal (MST) magnet arrays, respectively, for a high-precision positioning system. The proposed MST magnet array is a modified version of a Halbach magnet array. The MST array has trapezoidal magnets with variable shape and dimensions while the Halbach magnet array generally has a rectangular magnet with identical dimensions. We propose a new model that can describe the magnetic field resulting from the complex-shaped magnets. The model can be applied to both MST and conventional magnet arrays. Using the model, a design optimization of the two types of linear motors is performed and compared. The magnet array with trapezoidal magnets can produce more force than one with rectangular magnets when they are arrayed in a linear motor where there is a yoke with high permeability. After the optimization and comparison, we conclude that the linear motor with the MST magnet array can generate more actuating force per volume than the motor with the conventional array. In order to satisfy the requirements of next generation systems such as high resolution, high speed, and long stroke, the use of a linear motor with a MST array as an actuator in a high precision positioning system is recommended from the results obtained here

  7. Comparison of Thrust Characteristics in Pencil Sized Cylinder-type Linear Motors with Different Magnet Arrays

    OpenAIRE

    Nakaiwa, K; Yamada, A; Tashiro, K; Wakiwaka, H

    2009-01-01

    From a strong demand on the miniaturization of a chip mounter or a semiconductor device, the thrust improvement considering the magnets arrangement is studied. We accept a core stator with a Halbach type magnet array for a current linear motor. The thrust characteristics are compared with two kinds of mover, a NS magnet array and a Halbach magnet array.

  8. TiO2 beads and TiO2-chitosan beads for urease immobilization

    International Nuclear Information System (INIS)

    Ispirli Doğaç, Yasemin; Deveci, İlyas; Teke, Mustafa; Mercimek, Bedrettin

    2014-01-01

    The aim of the present study is to synthesize TiO 2 beads for urease immobilization. Two different strategies were used to immobilize the urease on TiO 2 beads. In the first method (A), urease enzyme was immobilized onto TiO 2 beads by adsorption and then crosslinking. In the second method (B), TiO 2 beads were coated with chitosan-urease mixture. To determine optimum conditions of immobilization, different parameters were investigated. The parameters of optimization were initial enzyme concentration (0.5; 1; 1.5; 2 mg/ml), alginate concentration (1; 2; 3%), glutaraldehyde concentration (1; 2; 3% v/v) and chitosan concentration (2; 3; 4 mg/ml). The optimum enzyme concentrations were determined as 1.5 mg/ml for A and 1.0 mg/ml for B. The other optimum conditions were found 2.0% (w/v) for alginate concentration (both A and B); 3.0 mg/ml for chitosan concentration (B) and 2.0% (v/v) for glutaraldehyde concentration (A). The optimum temperature (20-60 °C), optimum pH (3.0-10.0), kinetic parameters, thermal stability (4–70 °C), pH stability (4.0-9.0), operational stability (0-230 min) and reusability (20 times) were investigated for characterization. The optimum temperatures were 30 °C (A), 40 °C (B) and 35 °C (soluble). The temperature profiles of the immobilized ureases were spread over a large area. The optimum pH values for the soluble urease and immobilized urease prepared by using methods (A) and (B) were found to be 7.5, 7.0, 7.0, respectively. The thermal stabilities of immobilized enzyme sets were studied and they maintained 50% activity at 65 °C. However, at this temperature free urease protected only 15% activity. - Highlights: • TiO 2 and TiO 2 -chitosan beads for urease immobilization have been prepared and characterized. • The beads used in this work are good matrices for the immobilization of urease. • The immobilized urease was shown to have good properties and stabilities (pH and thermal stability, operational stability). • The 50

  9. Analysis and testing of a double armature brushless dc linear motor with NdFeB permanent magnets

    International Nuclear Information System (INIS)

    Filho, A.F.F.

    1998-01-01

    The use of high-energy product NdFeB permanent magnets benefits the design and features of a double armature brushless dc linear motor. As the linear motor is also slotless, its 5 mm airgap requires a source of high flux to overcome the reluctance and produce an adequate amount of force. The linear motor employs a topology that makes use of five permanent magnets to provide excitation flux. The permanent magnets are arranged in such a way that maximises the force the linear motor can deliver. The actuator produces a force up to 86.2 N at an armature current of 4.5 A. However, the topology makes the actuator prone to saturation. It affects the operation point of the permanent magnets, reduces the airgap flux density and the force, and increases flux leakage. To avoid saturation, a flux compensation scheme was conceived. The results are presented and assessed by means of finite element simulation and by experimental results that presented a good agreement. (orig.)

  10. Design and analysis of an unconventional permanent magnet linear machine for energy harvesting

    Science.gov (United States)

    Zeng, Peng

    This Ph.D. dissertation proposes an unconventional high power density linear electromagnetic kinetic energy harvester, and a high-performance two-stage interface power electronics to maintain maximum power abstraction from the energy source and charge the Li-ion battery load with constant current. The proposed machine architecture is composed of a double-sided flat type silicon steel stator with winding slots, a permanent magnet mover, coil windings, a linear motion guide and an adjustable spring bearing. The unconventional design of the machine is that NdFeB magnet bars in the mover are placed with magnetic fields in horizontal direction instead of vertical direction and the same magnetic poles are facing each other. The derived magnetic equivalent circuit model proves the average air-gap flux density of the novel topology is as high as 0.73 T with 17.7% improvement over that of the conventional topology at the given geometric dimensions of the proof-of-concept machine. Subsequently, the improved output voltage and power are achieved. The dynamic model of the linear generator is also developed, and the analytical equations of output maximum power are derived for the case of driving vibration with amplitude that is equal, smaller and larger than the relative displacement between the mover and the stator of the machine respectively. Furthermore, the finite element analysis (FEA) model has been simulated to prove the derived analytical results and the improved power generation capability. Also, an optimization framework is explored to extend to the multi-Degree-of-Freedom (n-DOF) vibration based linear energy harvesting devices. Moreover, a boost-buck cascaded switch mode converter with current controller is designed to extract the maximum power from the harvester and charge the Li-ion battery with trickle current. Meanwhile, a maximum power point tracking (MPPT) algorithm is proposed and optimized for low frequency driving vibrations. Finally, a proof

  11. Simulation of dynamics of a permanent magnet linear actuator

    DEFF Research Database (Denmark)

    Yatchev, Ivan; Ritchie, Ewen

    2010-01-01

    Comparison of two approaches for the simulation of the dynamic behaviour of a permanent magnet linear actuator is presented. These are full coupled model, where the electromagnetic field, electric circuit and mechanical motion problems are solved simultaneously, and decoupled model, where first...... flexibility when the actuator response is required to be estimated for different external conditions, e.g. external circuit parameters or mechanical loads....

  12. Magnetically Suspended Linear Pulse Motor for Semiconductor Wafer Transfer in Vacuum Chamber

    Science.gov (United States)

    Moriyama, Shin-Ichi; Hiraki, Naoji; Watanabe, Katsuhide; Kanemitsu, Yoichi

    1996-01-01

    This paper describes a magnetically suspended linear pulse motor for a semiconductor wafer transfer robot in a vacuum chamber. The motor can drive a wafer transfer arm horizontally without mechanical contact. In the construction of the magnetic suspension system, four pairs of linear magnetic bearings for the lift control are used for the guidance control as well. This approach allows us to make the whole motor compact in size and light in weight. The tested motor consists of a double-sided stator and a transfer arm with a width of 50 mm and a total length of 700 mm. The arm, like a ladder in shape, is designed as the floating element with a tooth width of 4 mm (a tooth pitch of 8 mm). The mover mass is limited to about 1.6 kg by adopting such an arm structure, and the ratio of thrust to mover mass reaches to 3.2 N/kg under a broad air gap (1 mm) between the stator teeth and the mover teeth. The performance testing was carried out with a transfer distance less than 450 mm and a transfer speed less than 560 mm/s. The attitude of the arm was well controlled by the linear magnetic bearings with a combined use, and consequently the repeatability on the positioning of the arm reached to about 2 micron. In addition, the positioning accuracy was improved up to about 30 micron through a compensation of the 128-step wave current which was used for the micro-step drive with a step increment of 62.5 micron.

  13. Vibration Stabilization of a Mechanical Model of a X-Band Linear Collider Final Focus Magnet

    CERN Document Server

    Frisch, J; Decker, V; Hendrickson, L; Markiewicz, T W; Partridge, R; Seryi, Andrei

    2004-01-01

    The small beam sizes at the interaction point of a X-band linear collider require mechanical stabilization of the final focus magnets at the nanometer level. While passive systems provide adequate performance at many potential sites, active mechanical stabilization is useful if the natural or cultural ground vibration is higher than expected. A mechanical model of a room temperature linear collider final focus magnet has been constructed and actively stabilized with an accelerometer based system.

  14. Vibration Stabilization of a Mechanical Model of a X-Band Linear Collider Final Focus Magnet

    International Nuclear Information System (INIS)

    Frisch, Josef; Chang, Allison; Decker, Valentin; Doyle, Eric; Eriksson, Leif; Hendrickson, Linda; Himel, Thomas; Markiewicz, Thomas; Partridge, Richard; Seryi, Andrei; SLAC

    2006-01-01

    The small beam sizes at the interaction point of a X-band linear collider require mechanical stabilization of the final focus magnets at the nanometer level. While passive systems provide adequate performance at many potential sites, active mechanical stabilization is useful if the natural or cultural ground vibration is higher than expected. A mechanical model of a room temperature linear collider final focus magnet has been constructed and actively stabilized with an accelerometer based system

  15. Calcium Pectinate Beads Formation: Shape and Size Analysis

    Directory of Open Access Journals (Sweden)

    Boon-Beng Lee

    2014-04-01

    Full Text Available The aim of this study was to investigate the inter-relationship between process variables and the size and shape of pectin solution droplets upon detachment from a dripping tip as well as Ca-pectinate beads formed after gelation via image analysis. The sphericity factor (SF of the droplets was generally smaller than 0.05. There was no specific trend between the SF of the droplets and the pectin concentration or the dripping tip radius. The SF the beads formed from high-concentration pectin solutions and a small dripping tip was smaller than 0.05. The results show that the Reynolds number and Ohnesorge number of the droplets fall within the operating region for forming spherical beads in the shape diagram, with the exception to the lower boundary. The lower boundary of the operating region has to be revised to Oh = 2.3. This is because the critical viscosity for Ca-pectinate bead formation is higher than that of Ca-alginate beads. On the other hand, the radius of the droplets and beads increased as the dripping tip radius increased. The bead radius can easily be predicted by Tate’s law equation.

  16. HPMA and HEMA copolymer bead interactions with eukaryotic cells

    Directory of Open Access Journals (Sweden)

    Cristina D. Vianna-Soares

    2004-09-01

    Full Text Available Two different hydrophilic acrylate beads were prepared via aqueous suspension polymerization. Beads produced of a hydroxypropyl methacrylate (HPMA and ethyleneglycol methacrylate (EDMA copolymer were obtained using a polyvinyl alcohol suspending medium. Copolymers of 2hydroxyethyl methacrylate (HEMA, methyl methacrylate (MMA and ethyleneglycol methacrylate (EDMA beads were obtained using magnesium hydroxide as the suspending agent. Following characterization by scanning electron microscopy (SEM, nitrogen sorption analysis (NSA and mercury intrusion porosimetry (MIP, the beads were cultured with monkey fibroblasts (COS7 to evaluate their ability to support cell growth, attachment and adhesion. Cell growth behavior onto small HPMA/EDMA copolymer beads and large HEMA/MMA/EDMA copolymer beads is evaluated regarding their hidrophilicity/hidrophobicity and surface roughness.

  17. Magnetic x-ray linear dichroism in resonant and non-resonant Gd 4f photoemission

    Energy Technology Data Exchange (ETDEWEB)

    Mishra, S.; Gammon, W.J.; Pappas, D.P. [Virginia Commonwealth Univ., Richmond, VA (United States)] [and others

    1997-04-01

    The enhancement of the magnetic linear dichroism in resonant 4f photoemission (MLDRPE) is studied from a 50 monolayer film of Gd/Y(0001). The ALS at beamline 7.0.1 provided the source of linearly polarized x-rays used in this study. The polarized light was incident at an angle of 30 degrees relative to the film plane, and the sample magnetization was perpendicular to the photon polarization. The linear dichroism of the 4f core levels is measured as the photon energy is tuned through the 4d-4f resonance. The authors find that the MLDRPE asymmetry is strongest at the resonance. Near the threshold the asymmetry has several features which are out of phase with the fine structure of the total yield.

  18. Magnetic x-ray linear dichroism in resonant and non-resonant Gd 4f photoemission

    International Nuclear Information System (INIS)

    Mishra, S.; Gammon, W.J.; Pappas, D.P.

    1997-01-01

    The enhancement of the magnetic linear dichroism in resonant 4f photoemission (MLDRPE) is studied from a 50 monolayer film of Gd/Y(0001). The ALS at beamline 7.0.1 provided the source of linearly polarized x-rays used in this study. The polarized light was incident at an angle of 30 degrees relative to the film plane, and the sample magnetization was perpendicular to the photon polarization. The linear dichroism of the 4f core levels is measured as the photon energy is tuned through the 4d-4f resonance. The authors find that the MLDRPE asymmetry is strongest at the resonance. Near the threshold the asymmetry has several features which are out of phase with the fine structure of the total yield

  19. Intracellular manipulation of chromatin using magnetic nanoparticles

    NARCIS (Netherlands)

    Kanger, Johannes S.; Subramaniam, Vinod; van Driel, Roel

    2008-01-01

    Magnetic tweezers are widely used for manipulating small magnetic beads inside the cell cytoplasm in order to gain insight into the structural and mechanical properties of the cytoskeleton. Here we discuss the use of magnetic tweezers for the study of nuclear architecture and the mechanical

  20. Detection of Escherichia coli O157:H7 and Salmonella in ground beef by a bead-free quantum dot-facilitated isolation method.

    Science.gov (United States)

    Wang, Luxin; Wu, Chung-Shieh; Fan, Xudong; Mustapha, Azlin

    2012-05-01

    The aims of this study were to introduce a new immunological bead-free cell detection method using quantum dots (QDs) as reporter markers for foodborne pathogen detection. QDs are nanosized particles with long-term photostability, high quantum yield, broad absorption spectra, and narrow, symmetric emission and high signal-to-noise ratio. The chemical compound [(1-ethyl-3-3-dimethylaminopropyl) carbodiimide hydrochloride] (EDC) and protein A were used as crosslinkers for manufacturing QD-antibody conjugates. To minimize the inhibition of QD fluorescence by the magnetic beads, the beads were removed after the primary pathogen isolation and before fluorescence measurement. Detection signals were increased four-fold after employing the bead-free isolation method. With a 24-h enrichment, the bead-free QD-facilitated detection method was able to detect 10 CFU/g Escherichia coli O157:H7 and Salmonella from artificially contaminated ground beef. To our knowledge, this detection method is the first research that combined a new EDC-protein A QD-labeling technique and bead-free fluorescence measurement to detect E. coli O157:H7 and Salmonella in ground beef. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. Microfluidic Platform for Enzyme-Linked and Magnetic Particle-Based Immunoassay

    Directory of Open Access Journals (Sweden)

    Dorota G. Pijanowska

    2013-06-01

    Full Text Available This article presents design and testing of a microfluidic platform for immunoassay. The method is based on sandwiched ELISA, whereby the primary antibody is immobilized on nitrocelluose and, subsequently, magnetic beads are used as a label to detect the analyte. The chip takes approximately 2 h and 15 min to complete the assay. A Hall Effect sensor using 0.35-μm BioMEMS TSMC technology (Taiwan Semiconductor Manufacturing Company Bio-Micro-Electro-Mechanical Systems was fabricated to sense the magnetic field from the beads. Furthermore, florescence detection and absorbance measurements from the chip demonstrate successful immunoassay on the chip. In addition, investigation also covers the Hall Effect simulations, mechanical modeling of the bead–protein complex, testing of the microfluidic platform with magnetic beads averaging 10 nm, and measurements with an inductor-based system.

  2. Entrapment of laurel lipase in chitosan hydrogel beads.

    Science.gov (United States)

    Yagar, Hulya; Balkan, Ugur

    2017-08-01

    Laurel seed lipase was entrapped within chitosan beads with ionotropic gelatin method using tripolyphosphate (TPP) as multivalent covalent counter ion. Immobilization yield was 78%. First, optimum immobilization conditions were determined, and morphology of chitosan beads was characterized by scanning electron microscopy. Optimum pH and temperature were evaluated as 6.0 and 40 °C, respectively. The immobilized beads saved about 55% of its activities at 60° while saved about 32% at 70 °C for 30 min. V max /K m values were determined as 31.75 and 2.87 using olive oil as substrate for immobilized beads and free enzyme, respectively. Immobilized beads showed the activities during 30 days at +4 °C.

  3. Bead-bead interaction parameters in dissipative particle dynamics: Relation to bead-size, solubility parameter, and surface tension

    Science.gov (United States)

    Maiti, Amitesh; McGrother, Simon

    2004-01-01

    Dissipative particle dynamics (DPD) is a mesoscale modeling method for simulating equilibrium and dynamical properties of polymers in solution. The basic idea has been around for several decades in the form of bead-spring models. A few years ago, Groot and Warren [J. Chem. Phys. 107, 4423 (1997)] established an important link between DPD and the Flory-Huggins χ-parameter theory for polymer solutions. We revisit the Groot-Warren theory and investigate the DPD interaction parameters as a function of bead size. In particular, we show a consistent scheme of computing the interfacial tension in a segregated binary mixture. Results for three systems chosen for illustration are in excellent agreement with experimental results. This opens the door for determining DPD interactions using interfacial tension as a fitting parameter.

  4. Investigation of a 7-pole/6-slot Halbach-magnetized permanent-magnet linear alternator used for free-piston stirling engines

    Science.gov (United States)

    Zheng, Ping; Tong, Chengde; Zhao, Jing; Yu, Bin; Li, Lin; Bai, Jingang; Zhang, Lu

    2012-04-01

    This paper investigates a 7-pole/6-slot Halbach-magnetized permanent-magnet linear alternator used for free piston Stirling engines (FPSEs). Taking the advantages of Halbach array, a 1 kW prototype alternator is designed. Considering the rms value of electromotive force (EMF) and harmonic distortion, the optimal length ratio of the axial- and radial-magnetized permanent magnets and thicknesses of the permanent magnets are optimized by 2D finite element method. The alternator detent force, which is an important factor for smooth operation of FPSEs, is studied by optimizing slot tip and end tooth. The load and thermal performances of the final design are simulated. A prototype alternator was designed, built and tested. Experimental data indicated satisfactory design.

  5. Controlled ice nucleation using freeze-dried Pseudomonas syringae encapsulated in alginate beads.

    Science.gov (United States)

    Weng, Lindong; Tessier, Shannon N; Swei, Anisa; Stott, Shannon L; Toner, Mehmet

    2017-04-01

    The control of ice nucleation is of fundamental significance in many process technologies related to food and pharmaceutical science and cryobiology. Mechanical perturbation, electromagnetic fields and ice-nucleating agents (INAs) have been known to induce ice nucleation in a controlled manner. But these ice-nucleating methods may suffer from cumbersome manual operations, safety concerns of external fields, and biocompatibility and recovery issues of INA particles, especially when used in living systems. Given the automatic ice-seeding nature of INAs, a promising solution to overcome some of the above limitations is to engineer a biocomposite that accommodates the INA particles but minimizes their interactions with biologics, as well as enabling the recovery of used particles. In this study, freeze-dried Pseudomonas syringae, a model ice-nucleating agent, was encapsulated into microliter-sized alginate beads. We evaluated the performance of the bacterial hydrogel beads to initiate ice nucleation in water and aqueous glycerol solution by investigating factors including the size and number of the beads and the local concentration of INA particles. In the aqueous sample of a fixed volume, the total mass of the INA particles (m) was found to be the governing parameter that is solely responsible for determining the ice nucleation performance of the bacterial hydrogel beads. The freezing temperature has a strong positive linear correlation with log 10 m. The findings in this study provide an effective, predictable approach to control ice nucleation, which can improve the outcome and standardization of many ice-assisted process technologies. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Application of magnetic poly(styrene-glycidyl methacrylate) microspheres for immunomagnetic separation of bone marrow cells

    Energy Technology Data Exchange (ETDEWEB)

    Chung, T.-H.; Chang, J.-Y. [Department of Chemical Engineering, National Chung Cheng University, Chiayi 621, Taiwan (China); Lee, W.-C. [Department of Chemical Engineering, National Chung Cheng University, Chiayi 621, Taiwan (China)], E-mail: chmwcl@ccu.edu.tw

    2009-05-15

    Surface-functionalized magnetic poly(styrene-glycidyl methacrylate) (PS-GMA) microspheres were prepared and coupled with Sca-1 antibody for cell selection from murine bone marrow mononuclear cells (MNCs). Biotinylated Sca-1 antibody could be directly coupled to avidin-bound magnetic microspheres. Alternatively, oxidized goat anti-mouse antibody was covalently bound onto the amino group-containing magnetic microspheres in a site-directed manner, and the resultant conjugate was coupled with non-modified Sca-1 antibody. Using the indirect antibody-bound magnetic microspheres, the purity of isolated Sca-1{sup +} cells increased with bead-to-cell ratio. Using a bead-to-cell ratio of 10 beads/cell, a purity of 85% Sca-1{sup +} cells corresponding to a 17-fold enrichment was achieved.

  7. Safeguards Analytical Laboratory evaluation program. Part 1. Resin bead mass spectrometry. Part 2. Results of a resin bead field experiment-Tastex-J

    International Nuclear Information System (INIS)

    Walker, R.L.; Smith, D.H.; Carter, J.A.; Musick, W.R.; Donohue, D.L.; Deron, S.; Asakura, Y.; Kagami, K.; Irinouchi, S.; Masui, J.

    1981-01-01

    The first part of this report covers background of resin bead spectrometry and the new batch resin bead method. In the original technique, about ten anion resin beads in the nitrate form were exposed to the diluted sample solution. The solution was adjusted to be a 8 M HNO 3 and to have about 1 μg U per bead. Up to 48 hours of static contact between beads and solution was required for adsorption of 1 to 3 ng Pu and U per bead to be achieved. Under these conditions, contamination was a problem at reprocessing facilities. The new batch techniques reduces the risk of contamination by handling one hundred times more U in the final diluted sample which is exposed to a proportionately larger number of beads. Moreover, it only requires ten minutes adsorption time to provide about 1000 purified samples for mass spectrometry. The amounts of Pu and U adsorbed versus time were determined and results are tabulated. The second part of this report briefly summarizes results of resin bead field tests completed at the Power Reactor and Nuclear Fuel Development Corporation (PNC) reprocessing plant in Tokai-mura, Japan. Both methods, the original small-sample resin bead and the batch technique, were investigated on spent fuel solutions. Beads were prepared at PNC and distributed to IAEA and ORNL along with dried residues for conventional mass spectrometric analysis at IAEA. Parallel measurements were made at PNC using their normal measuring routines. The U and Pu measurements of all resin and those of PNC are in excellent agreement for the batch method. Discrepancies were noted in the U measurements by the original method

  8. TiO₂ beads and TiO₂-chitosan beads for urease immobilization.

    Science.gov (United States)

    Ispirli Doğaç, Yasemin; Deveci, Ilyas; Teke, Mustafa; Mercimek, Bedrettin

    2014-09-01

    The aim of the present study is to synthesize TiO2 beads for urease immobilization. Two different strategies were used to immobilize the urease on TiO2 beads. In the first method (A), urease enzyme was immobilized onto TiO2 beads by adsorption and then crosslinking. In the second method (B), TiO2 beads were coated with chitosan-urease mixture. To determine optimum conditions of immobilization, different parameters were investigated. The parameters of optimization were initial enzyme concentration (0.5; 1; 1.5; 2mg/ml), alginate concentration (1; 2; 3%), glutaraldehyde concentration (1; 2; 3% v/v) and chitosan concentration (2; 3; 4 mg/ml). The optimum enzyme concentrations were determined as 1.5mg/ml for A and 1.0mg/ml for B. The other optimum conditions were found 2.0% (w/v) for alginate concentration (both A and B); 3.0mg/ml for chitosan concentration (B) and 2.0% (v/v) for glutaraldehyde concentration (A). The optimum temperature (20-60°C), optimum pH (3.0-10.0), kinetic parameters, thermal stability (4-70°C), pH stability (4.0-9.0), operational stability (0-230 min) and reusability (20 times) were investigated for characterization. The optimum temperatures were 30°C (A), 40°C (B) and 35°C (soluble). The temperature profiles of the immobilized ureases were spread over a large area. The optimum pH values for the soluble urease and immobilized urease prepared by using methods (A) and (B) were found to be 7.5, 7.0, 7.0, respectively. The thermal stabilities of immobilized enzyme sets were studied and they maintained 50% activity at 65°C. However, at this temperature free urease protected only 15% activity. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. A Linear Tetranuclear Dysprosium(III) Compound Showing Single-Molecule Magnet Behavior

    Energy Technology Data Exchange (ETDEWEB)

    Ke, Hongshan; Xu, Gong Feng; Guo, Yun-Nan; Gamez, Patrick; Beavers, Christine M; Teat, Simon J; Tang, Jinkui

    2010-04-20

    Although magnetic measurements reveal a single-relaxation time for a linear tetranuclear Dy(III) compound, the wide distribution of the relaxation time observed clearly suggests the presence of two slightly different anisotropic centres, therefore opening new avenues for investigating the relaxation dynamics of lanthanide aggregates.

  10. Tunable bead-on-string microstructures fabricated by mechano-electrospinning

    International Nuclear Information System (INIS)

    Bu Ningbin; Huang Yongan; Deng Huixu; Yin Zhouping

    2012-01-01

    In this paper, bead-on-string microstructures are fabricated by the mechano-electrospinning (MES) process in a continuously tunable manner. The thin jet is pulled onto the substrate by the stable electric field force and tunable mechanical drawing force, and then the bead-on-string structures are generated by means of the force exerted on the jet, which changes from capillary force and resisting viscosity force to friction force at the contact point in the horizontal direction. In a stable bead-on-string formation process, one cycle can be divided into three stages from the point of view of the jet behaviour: being anchored, being stretched, and skipping. The bead size and the bead gap are continuously tunable through the MES process. The fabrication mechanisms of the bead-on-string microstructure are uncovered through theoretical analysis and experimental characterization. When a critical velocity is achieved, the jet directly falls on the substrate without accumulation since the mechanical drawing force in the horizontal direction overtakes the capillary force, which leads the bead-on-string microstructures to a continuous fibre line. It is a flexible and highly controllable method to fabricate bead-on-string microstructures.

  11. A Controlled Drug-Delivery Experiment Using Alginate Beads

    Science.gov (United States)

    Farrell, Stephanie; Vernengo, Jennifer

    2012-01-01

    This paper describes a simple, cost-effective experiment which introduces students to drug delivery and modeling using alginate beads. Students produce calcium alginate beads loaded with drug and measure the rate of release from the beads for systems having different stir rates, geometries, extents of cross-linking, and drug molecular weight.…

  12. Adsorptive removal of Lead from water by the effective and reusable magnetic cellulose nanocomposite beads entrapping activated bentonite.

    Science.gov (United States)

    Luo, Xiaogang; Lei, Xiaojuan; Xie, Xiuping; Yu, Bo; Cai, Ning; Yu, Faquan

    2016-10-20

    Many efforts have been driven to decontaminate the drinking water, and the development of efficient adsorbents with the advantages of cost-effectiveness and operating convenience for the removal of Pb(2+) from water is a major challenge. This work was aimed to explore the possibility of using cellulose-based adsorbents for efficient adsorption of Pb(2+). The millimeter-scale magnetic cellulose-based nanocomposite beads were fabricated via an optimal extrusion dropping technology by blending cellulose with the carboxyl-functionalized magnetite nanoparticles and acid-activated bentonite in NaOH/urea aqueous solution, and then they had been tested to evaluate the effectiveness in the removal of Pb(2+) from water. The effects of contact time, initial heavy metal ion concentrations, adsorption isotherms and solution pH on the sorption behavior were studied. The thermodynamic parameters (ΔG, ΔH and ΔS) indicated that the adsorption processes were feasible, spontaneous, endothermic and mainly controlled by chemical mechanisms. The reusability of the adsorbent was also studied. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Demonstrations of the Action and Reaction Law and the Energy Conservation Law Using Fine Spherical Plastic Beads

    Science.gov (United States)

    Khumaeni, A.; Tanaka, S.; Kobayashi, A.; Lee, Y. I.; Kurniawan, K. H.; Ishii, K.; Kagawa, K.

    2008-01-01

    Equipment for demonstrating Newton's third law and the energy conservation law in mechanics have successfully been constructed utilizing fine spherical plastic beads in place of metal ball bearings. To demonstrate Newton's third law, special magnetized Petri dishes were employed as objects, while to examine the energy conservation law, a…

  14. Blood Compatibility of Sulfonated Cladophora Nanocellulose Beads

    Directory of Open Access Journals (Sweden)

    Igor Rocha

    2018-03-01

    Full Text Available Sulfonated cellulose beads were prepared by oxidation of Cladophora nanocellulose to 2,3-dialdehyde cellulose followed by sulfonation using bisulfite. The physicochemical properties of the sulfonated beads, i.e., high surface area, high degree of oxidation, spherical shape, and the possibility of tailoring the porosity, make them interesting candidates for the development of immunosorbent platforms, including their application in extracorporeal blood treatments. A desired property for materials used in such applications is blood compatibility; therefore in the present work, we investigate the hemocompatibility of the sulfonated cellulose beads using an in vitro whole blood model. Complement system activation (C3a and sC5b-9 levels, coagulation activation (thrombin-antithrombin (TAT levels and hemolysis were evaluated after whole blood contact with the sulfonated beads and the results were compared with the values obtained with the unmodified Cladophora nanocellulose. Results showed that neither of the cellulosic materials presented hemolytic activity. A marked decrease in TAT levels was observed after blood contact with the sulfonated beads, compared with Cladophora nanocellulose. However, the chemical modification did not promote an improvement in Cladophora nanocellulose hemocompatibility in terms of complement system activation. Even though the sulfonated beads presented a significant reduction in pro-coagulant activity compared with the unmodified material, further modification strategies need to be investigated to control the complement activation by the cellulosic materials.

  15. Blood Compatibility of Sulfonated Cladophora Nanocellulose Beads.

    Science.gov (United States)

    Rocha, Igor; Lindh, Jonas; Hong, Jaan; Strømme, Maria; Mihranyan, Albert; Ferraz, Natalia

    2018-03-07

    Sulfonated cellulose beads were prepared by oxidation of Cladophora nanocellulose to 2,3-dialdehyde cellulose followed by sulfonation using bisulfite. The physicochemical properties of the sulfonated beads, i.e., high surface area, high degree of oxidation, spherical shape, and the possibility of tailoring the porosity, make them interesting candidates for the development of immunosorbent platforms, including their application in extracorporeal blood treatments. A desired property for materials used in such applications is blood compatibility; therefore in the present work, we investigate the hemocompatibility of the sulfonated cellulose beads using an in vitro whole blood model. Complement system activation (C3a and sC5b-9 levels), coagulation activation (thrombin-antithrombin (TAT) levels) and hemolysis were evaluated after whole blood contact with the sulfonated beads and the results were compared with the values obtained with the unmodified Cladophora nanocellulose. Results showed that neither of the cellulosic materials presented hemolytic activity. A marked decrease in TAT levels was observed after blood contact with the sulfonated beads, compared with Cladophora nanocellulose. However, the chemical modification did not promote an improvement in Cladophora nanocellulose hemocompatibility in terms of complement system activation. Even though the sulfonated beads presented a significant reduction in pro-coagulant activity compared with the unmodified material, further modification strategies need to be investigated to control the complement activation by the cellulosic materials.

  16. Coated Aerogel Beads

    Science.gov (United States)

    Littman, Howard (Inventor); Plawsky, Joel L. (Inventor); Paccione, John D. (Inventor)

    2014-01-01

    Methods and apparatus for coating particulate material are provided. The apparatus includes a vessel having a top and a bottom, a vertically extending conduit having an inlet in the vessel and an outlet outside of the vessel, a first fluid inlet in the bottom of the vessel for introducing a transfer fluid, a second fluid inlet in the bottom of the vessel for introducing a coating fluid, and a fluid outlet from the vessel. The method includes steps of agitating a material, contacting the material with a coating material, and drying the coating material to produce a coated material. The invention may be adapted to coat aerogel beads, among other materials. A coated aerogel bead and an aerogel-based insulation material are also disclosed.

  17. Novel permanent magnet linear motor with isolated movers: analytical, numerical and experimental study.

    Science.gov (United States)

    Yan, Liang; Peng, Juanjuan; Jiao, Zongxia; Chen, Chin-Yin; Chen, I-Ming

    2014-10-01

    This paper proposes a novel permanent magnet linear motor possessing two movers and one stator. The two movers are isolated and can interact with the stator poles to generate independent forces and motions. Compared with conventional multiple motor driving system, it helps to increase the system compactness, and thus improve the power density and working efficiency. The magnetic field distribution is obtained by using equivalent magnetic circuit method. Following that, the formulation of force output considering armature reaction is carried out. Then inductances are analyzed with finite element method to investigate the relationships of the two movers. It is found that the mutual-inductances are nearly equal to zero, and thus the interaction between the two movers is negligible. A research prototype of the linear motor and a measurement apparatus on thrust force have been developed. Both numerical computation and experiment measurement are conducted to validate the analytical model of thrust force. Comparison shows that the analytical model matches the numerical and experimental results well.

  18. On-bead fluorescent DNA nanoprobes to analyze base excision repair activities

    Energy Technology Data Exchange (ETDEWEB)

    Gines, Guillaume; Saint-Pierre, Christine; Gasparutto, Didier, E-mail: didier.gasparutto@cea.fr

    2014-02-17

    Graphical abstract: -- Highlights: •On magnetic beads fluorescent enzymatic assays. •Simple, easy, non-radioactive and electrophoresis-free functional assay. •Lesion-containing hairpin DNA probes are selective for repair enzymes. •The biosensing platform allows the measurement of DNA repair activities from purified enzymes or within cell free extracts. -- Abstract: DNA integrity is constantly threatened by endogenous and exogenous agents that can modify its physical and chemical structure. Changes in DNA sequence can cause mutations sparked by some genetic diseases or cancers. Organisms have developed efficient defense mechanisms able to specifically repair each kind of lesion (alkylation, oxidation, single or double strand break, mismatch, etc). Here we report the adjustment of an original assay to detect enzymes’ activity of base excision repair (BER), that supports a set of lesions including abasic sites, alkylation, oxidation or deamination products of bases. The biosensor is characterized by a set of fluorescent hairpin-shaped nucleic acid probes supported on magnetic beads, each containing a selective lesion targeting a specific BER enzyme. We have studied the DNA glycosylase alkyl-adenine glycosylase (AAG) and the human AP-endonuclease (APE1) by incorporating within the DNA probe a hypoxanthine lesion or an abasic site analog (tetrahydrofuran), respectively. Enzymatic repair activity induces the formation of a nick in the damaged strand, leading to probe's break, that is detected in the supernatant by fluorescence. The functional assay allows the measurement of DNA repair activities from purified enzymes or in cell-free extracts in a fast, specific, quantitative and sensitive way, using only 1 pmol of probe for a test. We recorded a detection limit of 1 μg mL{sup −1} and 50 μg mL{sup −1} of HeLa nuclear extracts for APE1 and AAG enzymes, respectively. Finally, the on-bead assay should be useful to screen inhibitors of DNA repair

  19. A novel multiplex bead-based platform highlights the diversity of extracellular vesicles.

    Science.gov (United States)

    Koliha, Nina; Wiencek, Yvonne; Heider, Ute; Jüngst, Christian; Kladt, Nikolay; Krauthäuser, Susanne; Johnston, Ian C D; Bosio, Andreas; Schauss, Astrid; Wild, Stefan

    2016-01-01

    The surface protein composition of extracellular vesicles (EVs) is related to the originating cell and may play a role in vesicle function. Knowledge of the protein content of individual EVs is still limited because of the technical challenges to analyse small vesicles. Here, we introduce a novel multiplex bead-based platform to investigate up to 39 different surface markers in one sample. The combination of capture antibody beads with fluorescently labelled detection antibodies allows the analysis of EVs that carry surface markers recognized by both antibodies. This new method enables an easy screening of surface markers on populations of EVs. By combining different capture and detection antibodies, additional information on relative expression levels and potential vesicle subpopulations is gained. We also established a protocol to visualize individual EVs by stimulated emission depletion (STED) microscopy. Thereby, markers on single EVs can be detected by fluorophore-conjugated antibodies. We used the multiplex platform and STED microscopy to show for the first time that NK cell-derived EVs and platelet-derived EVs are devoid of CD9 or CD81, respectively, and that EVs isolated from activated B cells comprise different EV subpopulations. We speculate that, according to our STED data, tetraspanins might not be homogenously distributed but may mostly appear as clusters on EV subpopulations. Finally, we demonstrate that EV mixtures can be separated by magnetic beads and analysed subsequently with the multiplex platform. Both the multiplex bead-based platform and STED microscopy revealed subpopulations of EVs that have been indistinguishable by most analysis tools used so far. We expect that an in-depth view on EV heterogeneity will contribute to our understanding of different EVs and functions.

  20. Ecohydraulics of Strings and Beads in Bedrock Rivers

    Science.gov (United States)

    Wohl, E.

    2016-12-01

    Twenty years ago, Jack Stanford and others described rivers in bedrock canyons as resembling beads on a string when viewed in planform. The beads are relatively wide, low gradient river segments with floodplains, whereas the strings are the intervening steep, narrow river segments with minimal floodplain development. This pattern of longitudinal variations in channel and valley morphology along bedrock canyon rivers is very common, from small channels to major rivers such as the Colorado. Basic understanding of river ecosystems, as well as limited studies, indicates that the beads are more retentive and biologically productive. Although both strings and beads can provide habitat for diverse organisms, strings are more likely to serve as migration corridors, whereas beads provide spawning and nursery habitat, facilitate lateral (channel-floodplain) and vertical (channel-hyporheic) exchanges and associated habitat diversity, and retain dissolved and particulate organic matter. Recognition of the different characteristics and functions of strings and beads can be used to identify their spatial distribution along a river or within a river network and the hydraulically driven processes that sustain channel form, water quality, and biota within strings and beads. Diverse modeling approaches can then be used to quantify the fluxes of water and sediment needed to maintain these hydraulically driven processes. This conceptual framework is illustrated using examples from mountain streams in the Southern Rockies and canyon rivers in the southwestern United States.

  1. SparseBeads data: benchmarking sparsity-regularized computed tomography

    Science.gov (United States)

    Jørgensen, Jakob S.; Coban, Sophia B.; Lionheart, William R. B.; McDonald, Samuel A.; Withers, Philip J.

    2017-12-01

    Sparsity regularization (SR) such as total variation (TV) minimization allows accurate image reconstruction in x-ray computed tomography (CT) from fewer projections than analytical methods. Exactly how few projections suffice and how this number may depend on the image remain poorly understood. Compressive sensing connects the critical number of projections to the image sparsity, but does not cover CT, however empirical results suggest a similar connection. The present work establishes for real CT data a connection between gradient sparsity and the sufficient number of projections for accurate TV-regularized reconstruction. A collection of 48 x-ray CT datasets called SparseBeads was designed for benchmarking SR reconstruction algorithms. Beadpacks comprising glass beads of five different sizes as well as mixtures were scanned in a micro-CT scanner to provide structured datasets with variable image sparsity levels, number of projections and noise levels to allow the systematic assessment of parameters affecting performance of SR reconstruction algorithms6. Using the SparseBeads data, TV-regularized reconstruction quality was assessed as a function of numbers of projections and gradient sparsity. The critical number of projections for satisfactory TV-regularized reconstruction increased almost linearly with the gradient sparsity. This establishes a quantitative guideline from which one may predict how few projections to acquire based on expected sample sparsity level as an aid in planning of dose- or time-critical experiments. The results are expected to hold for samples of similar characteristics, i.e. consisting of few, distinct phases with relatively simple structure. Such cases are plentiful in porous media, composite materials, foams, as well as non-destructive testing and metrology. For samples of other characteristics the proposed methodology may be used to investigate similar relations.

  2. Study on the etched carnelian beads unearthed in China

    Institute of Scientific and Technical Information of China (English)

    Deyun Zhao

    2014-01-01

    Etched carnelian beads originated in the Indus Civilization;this kind of ornaments and its manufacturing techniques were spread to the whole Eurasia Continent.The etched carnelian beads unearthed in China can be classified into four types,the comparisons of which to their foreign counterparts may reveal their different sources and diffusion routes.The etched carnelian beads and their glass imitations unearthed in China had influences to the making of the glass "eye beads" in

  3. Contactless and absolute linear displacement detection based upon 3D printed magnets combined with passive radio-frequency identification

    Science.gov (United States)

    Windl, Roman; Abert, Claas; Bruckner, Florian; Huber, Christian; Vogler, Christoph; Weitensfelder, Herbert; Suess, Dieter

    2017-11-01

    Within this work a passive and wireless magnetic sensor, to monitor linear displacements, is proposed. We exploit recent advances in 3D printing and fabricate a polymer bonded magnet with a spatially linear magnetic field component corresponding to the length of the magnet. Regulating the magnetic compound fraction during printing allows specific shaping of the magnetic field distribution. A giant magnetoresistance magnetic field sensor is combined with a radio-frequency identification tag in order to passively monitor the exerted magnetic field of the printed magnet. Due to the tailored magnetic field, a displacement of the magnet with respect to the sensor can be detected within the sub-mm regime. The sensor design provides good flexibility by controlling the 3D printing process according to application needs. Absolute displacement detection using low cost components and providing passive operation, long term stability, and longevity renders the proposed sensor system ideal for structural health monitoring applications.

  4. Contactless and absolute linear displacement detection based upon 3D printed magnets combined with passive radio-frequency identification

    Directory of Open Access Journals (Sweden)

    Roman Windl

    2017-11-01

    Full Text Available Within this work a passive and wireless magnetic sensor, to monitor linear displacements, is proposed. We exploit recent advances in 3D printing and fabricate a polymer bonded magnet with a spatially linear magnetic field component corresponding to the length of the magnet. Regulating the magnetic compound fraction during printing allows specific shaping of the magnetic field distribution. A giant magnetoresistance magnetic field sensor is combined with a radio-frequency identification tag in order to passively monitor the exerted magnetic field of the printed magnet. Due to the tailored magnetic field, a displacement of the magnet with respect to the sensor can be detected within the sub-mm regime. The sensor design provides good flexibility by controlling the 3D printing process according to application needs. Absolute displacement detection using low cost components and providing passive operation, long term stability, and longevity renders the proposed sensor system ideal for structural health monitoring applications.

  5. Inhibitive Effect of antibiotic-loaded beads to cure chronic osteomyelitis in developing country : Hand-made vs commercial beads

    NARCIS (Netherlands)

    Rasyid, Hcrmawan N.; Van Horn, Jim R.; Van der Mei, Henny C.; Soegijoko, Sooegijardjo; Busscher, Henk J.; Neut, Danielle; Ibrahim, F; Osman, NAA; Usman, J; Kadri, NA

    2007-01-01

    Local antibiotic-loaded beads have been approved for standard treatment of orthopaedic pathogens, especially chronic osteomyelitis. Septopal (R), the only commercial local antibiotic bead available on the market, is expensive and contains only gentamicin. This study aimed to compare the in vitro

  6. Multifunctional Magnetic and Upconverting Nanobeads as Dual Modal Imaging Tools.

    Science.gov (United States)

    Materia, Maria Elena; Pernia Leal, Manuel; Scotto, Marco; Balakrishnan, Preethi Bala; Kumar Avugadda, Sahitya; García-Martín, María L; Cohen, Bruce E; Chan, Emory M; Pellegrino, Teresa

    2017-11-15

    We report the fabrication of aqueous multimodal imaging nanocomposites based on superparamagnetic nanoparticles (MNPs) and two different sizes of photoluminescent upconverting nanoparticles (UCNPs). The controlled and simultaneous incorporation of both types of nanoparticles (NPs) was obtained by controlling the solvent composition and the addition rate of the destabilizing solvent. The magnetic properties of the MNPs remained unaltered after their encapsulation into the polymeric beads as shown by the T2 relaxivity measurements. The UCNPs maintain photoluminescent properties even when embedded with the MNPs into the polymer bead. Moreover, the light emitted by the magnetic and upconverting nanobeads (MUCNBs) under NIR excitation (λ exc = 980 nm) was clearly observed through different thicknesses of agarose gel or through a mouse skin layer. The comparison with magnetic and luminescent nanobeads based on red-emitting quantum dots (QDs) demonstrated that while the QD-based beads show significant autofluorescence background from the skin, the signal obtained by the MUCNBs allows a decrease in this background. In summary, these results indicate that MUCNBs are good magnetic and optical probes for in vivo multimodal imaging sensors.

  7. Commercial glass beads as TLDs in radiotherapy produced by different manufacturers

    Science.gov (United States)

    Jafari, S. M.; Bates, N. M.; Jupp, T.; Abdul Sani, S. F.; Nisbet, A.; Bradley, D. A.

    2017-08-01

    While commercial jewellery glass beads offer the basis of novel radiotherapy TL dosimetry (Jafari et al. 2014a,b,c, 2015a,b), detailed study of TL variation is required for the products from various manufacturers. Investigation is made for glass beads from four manufacturers from four countries: China (Rocaille), Japan (Mill Hill), Indonesia (TOHO™) and Czech Republic (Czech). Sample composition was determined using an energy-dispersive X-ray unit coupled to a scanning electron microscope. Values of mass attenuation coefficient, μ/ρ, as a function of photon energy were then calculated for photons of energy 1 keV to 10 MeV, using the National Institute of Standards and Technology XCOM program. Radiation and energy response were determined using X-rays generated at accelerating potentials from 80 kVp to 6 MV (TPR20/10=0.670). All bead types showed TL to be linear with dose (R2>0.999). Glow curve dosimetric peaks reached a maximum value at 300 °C for the Toho and 290 °C for the Czech and Mill Hill products but was between 200-250 °C for the Rocaille product. Radiation sensitivity following mass normalisation varied within an order of magnitude; Toho samples showed the greatest and Rocaille the least sensitivity. For the Toho, Czech, Rocaille and Mill Hill samples the energy responses at 80 kVp were 5.0, 4.0, 3.6 and 3.3 times that obtained at 6 MV. All four glass bead types offer potential use as TL dosimeters over doses commonly applied in radiotherapy. Energy response variation was <1% at 6 MV but significant variation was found for photon beam energies covering the kV range; careful characterisation is required if use at this range is intended.

  8. MODELING OF OPERATION OF COAXIAL-LINEAR MOTORS WITH AXIAL AND RADIAL DIRECTIONS OF MAGNETIZATION OF PERMANENT MAGNETS IN DYNAMIC MODE

    Directory of Open Access Journals (Sweden)

    G.M. Golenkov

    2014-12-01

    Full Text Available Theoretical and experimental investigations of the amplitude, phase and inertia-power frequency characteristics of two types of coaxial-linear electric motors of back-and-forth motion with permanent magnets, which magnetization vector is directed axially and radially relative to the axis of the runner are carried out. The comparative analysis of characteristics of these motors is presented.

  9. Creating nanoshell on the surface of titanium hydride bead

    Directory of Open Access Journals (Sweden)

    PAVLENKO Vyacheslav Ivanovich

    2016-12-01

    Full Text Available The article presents data on the modification of titanium hydride bead by creating titanium nanoshell on its surface by ion-plasma vacuum magnetron sputtering. To apply titanium nanoshell on the titanium hydride bead vacuum coating plant of multifunctional nanocomposite coatings QVADRA 500 located in the center of high technology was used. Analysis of the micrographs of the original surface of titanium hydride bead showed that the microstructure of the surface is flat, smooth, in addition the analysis of the microstructure of material surface showed the presence of small porosity, roughness, mainly cavities, as well as shallow longitudinal cracks. The presence of oxide film in titanium hydride prevents the free release of hydrogen and fills some micro-cracks on the surface. Differential thermal analysis of both samples was conducted to determine the thermal stability of the initial titanium hydride bead and bead with applied titanium nanoshell. Hydrogen thermal desorption spectra of the samples of the initial titanium hydride bead and bead with applied titanium nanoshell show different thermal stability of compared materials in the temperature range from 550 to 860о C. Titanium nanoshells applied in this way allows increasing the heat resistance of titanium hydride bead – the temperature of starting decomposition is 695о C and temperature when decomposition finishes is more than 1000о C. Modified in this way titanium hydride bead can be used as a filler in the radiation protective materials used in the construction or upgrading biological protection of nuclear power plants.

  10. Calibration beads containing luminescent lanthanide ion complexes

    Science.gov (United States)

    The reliability of lanthanide luminescence measurements, by both flow cytometry and digital microscopy, will be enhanced by the availability of narrow-band emitting lanthanide calibration beads. These beads can also be used to characterize spectrographic instruments, including mi...

  11. Damping and non-linearity of a levitating magnet in rotation above a superconductor

    International Nuclear Information System (INIS)

    Druge, J; Jean, C; Laurent, O; Méasson, M-A; Favero, I

    2014-01-01

    We study the dissipation of moving magnets in levitation above a superconductor. The rotation motion is analyzed using optical tracking techniques. It displays a remarkable regularity together with long damping time up to several hours. The magnetic contribution to the damping is investigated in detail by comparing 14 distinct magnetic configurations and points towards amplitude-dependent dissipation mechanisms. The non-linear dynamics of the mechanical rotation motion is also revealed and described with an effective Duffing model. The magnetic mechanical damping is consistent with measured hysteretic cycles M(H) that are discussed within a modified critical state model. The obtained picture of the coupling of levitating magnets to their environment sheds light on their potential as ultra-low dissipation mechanical oscillators for high precision physics. (paper)

  12. Development of a PCR/LDR/flow-through hybridization assay using a capillary tube, probe DNA-immobilized magnetic beads and chemiluminescence detection.

    Science.gov (United States)

    Hommatsu, Manami; Okahashi, Hisamitsu; Ohta, Keisuke; Tamai, Yusuke; Tsukagoshi, Kazuhiko; Hashimoto, Masahiko

    2013-01-01

    A polymerase chain reaction (PCR)/ligase detection reaction (LDR)/flow-through hybridization assay using chemiluminescence (CL) detection was developed for analyzing point mutations in gene fragments with high diagnostic value for colorectal cancers. A flow-through hybridization format using a capillary tube, in which probe DNA-immobilized magnetic beads were packed, provided accelerated hybridization kinetics of target DNA (i.e. LDR product) to the probe DNA. Simple fluid manipulations enabled both allele-specific hybridization and the removal of non-specifically bound DNA in the wash step. Furthermore, the use of CL detection greatly simplified the detection scheme, since CL does not require a light source for excitation of the fluorescent dye tags on the LDR products. Preliminary results demonstrated that this analytical system could detect both homozygous and heterozygous mutations, without the expensive instrumentation and cumbersome procedures required by conventional DNA microarray-based methods.

  13. Discrete dipole approximation simulation of bead enhanced diffraction grating biosensor

    International Nuclear Information System (INIS)

    Arif, Khalid Mahmood

    2016-01-01

    We present the discrete dipole approximation simulation of light scattering from bead enhanced diffraction biosensor and report the effect of bead material, number of beads forming the grating and spatial randomness on the diffraction intensities of 1st and 0th orders. The dipole models of gratings are formed by volume slicing and image processing while the spatial locations of the beads on the substrate surface are randomly computed using discrete probability distribution. The effect of beads reduction on far-field scattering of 632.8 nm incident field, from fully occupied gratings to very coarse gratings, is studied for various bead materials. Our findings give insight into many difficult or experimentally impossible aspects of this genre of biosensors and establish that bead enhanced grating may be used for rapid and precise detection of small amounts of biomolecules. The results of simulations also show excellent qualitative similarities with experimental observations. - Highlights: • DDA was used to study the relationship between the number of beads forming gratings and ratio of first and zeroth order diffraction intensities. • A very flexible modeling program was developed to design complicated objects for DDA. • Material and spatial effects of bead distribution on surfaces were studied. • It has been shown that bead enhanced grating biosensor can be useful for fast detection of small amounts of biomolecules. • Experimental results qualitatively support the simulations and thus open a way to optimize the grating biosensors.

  14. Microarray of DNA probes on carboxylate functional beads surface

    Institute of Scientific and Technical Information of China (English)

    黄承志; 李原芳; 黄新华; 范美坤

    2000-01-01

    The microarray of DNA probes with 5’ -NH2 and 5’ -Tex/3’ -NH2 modified terminus on 10 um carboxylate functional beads surface in the presence of 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide (EDC) is characterized in the preseni paper. it was found that the microarray capacity of DNA probes on the beads surface depends on the pH of the aqueous solution, the concentra-tion of DNA probe and the total surface area of the beads. On optimal conditions, the minimum distance of 20 mer single-stranded DNA probe microarrayed on beads surface is about 14 nm, while that of 20 mer double-stranded DNA probes is about 27 nm. If the probe length increases from 20 mer to 35 mer, its microarray density decreases correspondingly. Mechanism study shows that the binding mode of DNA probes on the beads surface is nearly parallel to the beads surface.

  15. Microarray of DNA probes on carboxylate functional beads surface

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    The microarray of DNA probes with 5′-NH2 and 5′-Tex/3′-NH2 modified terminus on 10 m m carboxylate functional beads surface in the presence of 1-ethyl-3-(3-dimethylaminopropyl)- carbodiimide (EDC) is characterized in the present paper. It was found that the microarray capacity of DNA probes on the beads surface depends on the pH of the aqueous solution, the concentration of DNA probe and the total surface area of the beads. On optimal conditions, the minimum distance of 20 mer single-stranded DNA probe microarrayed on beads surface is about 14 nm, while that of 20 mer double-stranded DNA probes is about 27 nm. If the probe length increases from 20 mer to 35 mer, its microarray density decreases correspondingly. Mechanism study shows that the binding mode of DNA probes on the beads surface is nearly parallel to the beads surface.

  16. Effects of agitation rate on aggregation during beads-to-beads subcultivation of microcarrier culture of human mesenchymal stem cells.

    Science.gov (United States)

    Takahashi, Iori; Sato, Keigo; Mera, Hisashi; Wakitani, Shigeyuki; Takagi, Mutsumi

    2017-06-01

    With the aim to utilize human mesenchymal stem cells (hMSCs) grown in large scale for regenerative medicine, effects of agitation rate on aggregation during beads-to-beads subcultivation of microcarrier culture of hMSCs were studied. hMSCs could attach and grew on surface-type microcarriers of Cytodex 1, whereas almost no cell elongation and growth were observed on porous type microcarriers of Cytopores. The percentages of aggregated Cytodex 1 microcarriers at an agitation rate of 60 and 90 rpm were lower than that at 30 rpm, which was the lowest agitation rate necessary for the suspension of Cytodex 1 microcarriers, and the cells grew fastest at 60 rpm. hMSC could be subcultivated on Cytodex 1 by the beads-to-beads method at both 30 and 60 rpm without trypsinization. However, agitation at 60 rpm resulted in a markedly lower percentage of aggregated microcarriers not only before but also after subcultivation. The percentages of CD90- and CD166-positive cells among cells grown on Cytodex 1 at 60 rpm (91.5 and 87.6 %) were comparable to those of cells grown in the pre-culture on dishes. In conclusion, hMSCs could be subcultivated on Cytodex 1 by beads-to-beads method maintaining the expressions of the cell surface antigens CD90 and CD166, while adjusting agitation rate could decrease the microcarrier aggregation.

  17. Combined Simulation of a Micro Permanent Magnetic Linear Contactless Displacement Sensor

    Directory of Open Access Journals (Sweden)

    Jing Gao

    2010-09-01

    Full Text Available The permanent magnetic linear contactless displacement (PLCD sensor is a new type of displacement sensor operating on the magnetic inductive principle. It has many excellent properties and has already been used for many applications. In this article a Micro-PLCD sensor which can be used for microelectromechanical system (MEMS measurements is designed and simulated with the CST EM STUDIO® software, including building a virtual model, magnetostatic calculations, low frequency calculations, steady current calculations and thermal calculations. The influence of some important parameters such as air gap dimension, working frequency, coil current and eddy currents etc. is studied in depth.

  18. Linear magnetic anomalies and tectonic development of the middle Okinawa Trough

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    -By analyzing the magnetic anomalies, the linear magnetic anomalies in the middle Okinawa Trough are identified. It means that the crust along the spreading axis is broken, and new oceanic crust is formed. Geophysical data have revealed that a model of three extensive episodes occurs in the Okinawa Trough, which can be named as "doming episode" from the Middle to Late Miocene (Phase I), the episode from the Pliocence to Early Pleistocene (Phase Ⅱ ), and the recent "spreading episode" (Phase Ⅲ ). The magnetic anomalies in the middle Okinawa Trough are very similar to those found in the middle Red Sea, indicating that the Okinawa Trough is developing towards the "Red Sea stage". Similar to the Red Sea, there are a "main trough" and a "axial trough" in the Okinawa Trough.

  19. Half bead welding technique

    International Nuclear Information System (INIS)

    Canonico, D.A.; Holz, P.P.

    1978-05-01

    The ORNL has employed the Section XI half-bead procedure for six repair welds. Table 2 identifies the repairs and the components upon which they were accomplished. The weld repairs were performed to permit us to evaluate material properties, residual stresses, weld repair procedures, and structural behavior of repaired pressure vessels. As a consequence of our study we concluded that when the half bead procedure is correctly applied: (1) there is no metallurgical degradation of the base material, (2) residual stresses of yield point magnitude will be present, and (3) the structural integrity of the pressure vessel is not impaired at Charpy V-notch upper shelf temperatures

  20. Magnetic Properties of linear chain compounds formed by lanthanide (III) ions and nitronyl-nitroxide radicals

    Energy Technology Data Exchange (ETDEWEB)

    Benelli, C.; Caneschi, A.; Gatteschi, D.; Pardi, L. (Florence Univ. (IT)); Rey, P. (CEA Centre d' Etudes Nucleaires de Grenoble, 38 (FR). Dept. de Recherche Fondamentale)

    1988-12-01

    The magnetic properties of novel linear chain compounds containing lanthanide (III) ions (gadolinium, europium) coupled to stable nitronyl-nitroxide radicals are reported. The metal ions and the radicals are regularly alternating along the chain. The magnetic behaviors appears to be dominated by antiferromagnetic interactions between the radicals.

  1. Magnetic Properties of linear chain compounds formed by lanthanide (III) ions and nitronyl-nitroxide radicals

    International Nuclear Information System (INIS)

    Benelli, C.; Caneschi, A.; Gatteschi, D.; Pardi, L.; Rey, P.

    1988-01-01

    The magnetic properties of novel linear chain compounds containing lanthanide (III) ions (gadolinium, europium) coupled to stable nitronyl-nitroxide radicals are reported. The metal ions and the radicals are regularly alternating along the chain. The magnetic behaviors appears to be dominated by antiferromagnetic interactions between the radicals

  2. System of coefficients for charged-particle beam linear transformation by a magnetic dipole element

    International Nuclear Information System (INIS)

    Tarantin, N.I.

    1979-01-01

    A new technique for consideration of dipole magnet ion-optical effect has been developed to study the problems of commutation and monochromatization of a charged particle beam. In a new form obtained are systematized coefficients of linear transformation (CLT) of the charged particle beam for radial and axial motions in a magnetic dipole element (MDE) including a dipole magnet and two gaps without magnetic field. Given is a method of graphic determination of MDE parameters and main CLT. The new form of coefficients and conditions of the transformations feasibility considerably facilitates the choice and calculation of dipole elements

  3. Complexation of Polyelectrolyte Micelles with Oppositely Charged Linear Chains.

    Science.gov (United States)

    Kalogirou, Andreas; Gergidis, Leonidas N; Miliou, Kalliopi; Vlahos, Costas

    2017-03-02

    The formation of interpolyelectrolyte complexes (IPECs) from linear AB diblock copolymer precursor micelles and oppositely charged linear homopolymers is studied by means of molecular dynamics simulations. All beads of the linear polyelectrolyte (C) are charged with elementary quenched charge +1e, whereas in the diblock copolymer only the solvophilic (A) type beads have quenched charge -1e. For the same Bjerrum length, the ratio of positive to negative charges, Z +/- , of the mixture and the relative length of charged moieties r determine the size of IPECs. We found a nonmonotonic variation of the size of the IPECs with Z +/- . For small Z +/- values, the IPECs retain the size of the precursor micelle, whereas at larger Z +/- values the IPECs decrease in size due to the contraction of the corona and then increase as the aggregation number of the micelle increases. The minimum size of the IPECs is obtained at lower Z +/- values when the length of the hydrophilic block of the linear diblock copolymer decreases. The aforementioned findings are in agreement with experimental results. At a smaller Bjerrum length, we obtain the same trends but at even smaller Z +/- values. The linear homopolymer charged units are distributed throughout the corona.

  4. Two Contrasting Failure Modes of Enteric Coated Beads.

    Science.gov (United States)

    Shi, Galen H; Dong, Xia; Lytle, Michelle; Kemp, Craig A J; Behme, Robert J; Hinds, Jeremy; Xiao, Zhicheng

    2018-04-09

    This study aimed to elucidate the mechanisms and kinetics of coating failure for enteric coated beads exposed to high-humidity conditions at different storage temperatures. Enteric coated beads were placed on high-humidity conditions (75 to 98% relative humidity (RH)) in the temperature range of 5 to 40°C. These stability samples of beads were tested for acid dissolution and water activity and also analyzed with SEM, X-ray CT, and DMA. Exposure of enteric coated beads to high humidity led to increased gastric release of drug which eventually failed the dissolution specification. SEM showed visible cracks on the surface of beads exposed to 5°C/high humidity and fusion of enteric beads into agglomerates at 40°C/high humidity. In a non-destructive time elapse study, X-ray CT demonstrated swelling of microcrystalline cellulose cores, crack initiation, and propagation through the API layer within days under 5°C/98% RH storage conditions and ultimately fracture through the enteric coating. DMA data showed a marked reduction in T g of the enteric coating materials after exposure to humidity. At 5°C/high humidity, the hygroscopic microcrystalline cellulose core absorbed moisture leading to core swelling and consequent fracture through the brittle API and enteric layers. At 40°C (high humidity) which is above the T g of the enteric polymer, enteric coated beads coalesced into agglomerates due to melt flow of the enteric coating. We believe it is the first report on two distinct failure models of enteric coated dosage forms.

  5. Linear arrangement of nano-scale magnetic particles formed in Cu-Fe-Ni alloys

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Sung, E-mail: k3201s@hotmail.co [Department of Materials Engineering (SEISAN), Yokohama National University, 79-5 Tokiwadai, Hodogayaku, Yokohama, 240-8501 (Japan); Takeda, Mahoto [Department of Materials Engineering (SEISAN), Yokohama National University, 79-5 Tokiwadai, Hodogayaku, Yokohama, 240-8501 (Japan); Takeguchi, Masaki [Advanced Electron Microscopy Group, National Institute for Materials Science (NIMS), Sakura 3-13, Tsukuba, 305-0047 (Japan); Bae, Dong-Sik [School of Nano and Advanced Materials Engineering, Changwon National University, Gyeongnam, 641-773 (Korea, Republic of)

    2010-04-30

    The structural evolution of nano-scale magnetic particles formed in Cu-Fe-Ni alloys on isothermal annealing at 878 K has been investigated by means of transmission electron microscopy (TEM), electron dispersive X-ray spectroscopy (EDS), electron energy-loss spectroscopy (EELS) and field-emission scanning electron microscopy (FE-SEM). Phase decomposition of Cu-Fe-Ni occurred after an as-quenched specimen received a short anneal, and nano-scale magnetic particles were formed randomly in the Cu-rich matrix. A striking feature that two or more nano-scale particles with a cubic shape were aligned linearly along <1,0,0> directions was observed, and the trend was more pronounced at later stages of the precipitation. Large numbers of <1,0,0> linear chains of precipitates extended in three dimensions in late stages of annealing.

  6. On-Chip Magnetic Platform for Single-Particle Manipulation with Integrated Electrical Feedback.

    Science.gov (United States)

    Monticelli, Marco; Torti, Andrea; Cantoni, Matteo; Petti, Daniela; Albisetti, Edoardo; Manzin, Alessandra; Guerriero, Erica; Sordan, Roman; Gervasoni, Giacomo; Carminati, Marco; Ferrari, Giorgio; Sampietro, Marco; Bertacco, Riccardo

    2016-02-17

    Methods for the manipulation of single magnetic particles have become very interesting, in particular for in vitro biological studies. Most of these studies require an external microscope to provide the operator with feedback for controlling the particle motion, thus preventing the use of magnetic particles in high-throughput experiments. In this paper, a simple and compact system with integrated electrical feedback is presented, implementing in the very same device both the manipulation and detection of the transit of single particles. The proposed platform is based on zig-zag shaped magnetic nanostructures, where transverse magnetic domain walls are pinned at the corners and attract magnetic particles in suspension. By applying suitable external magnetic fields, the domain walls move to the nearest corner, thus causing the step by step displacement of the particles along the nanostructure. The very same structure is also employed for detecting the bead transit. Indeed, the presence of the magnetic particle in suspension over the domain wall affects the depinning field required for its displacement. This characteristic field can be monitored through anisotropic magnetoresistance measurements, thus implementing an integrated electrical feedback of the bead transit. In particular, the individual manipulation and detection of single 1-μm sized beads is demonstrated. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Dual Recognition Strategy for Specific and Sensitive Detection of Bacteria Using Aptamer-Coated Magnetic Beads and Antibiotic-Capped Gold Nanoclusters.

    Science.gov (United States)

    Cheng, Dan; Yu, Mengqun; Fu, Fei; Han, Weiye; Li, Gan; Xie, Jianping; Song, Yang; Swihart, Mark T; Song, Erqun

    2016-01-05

    Food poisoning and infectious diseases caused by pathogenic bacteria such as Staphylococcus aureus (SA) are serious public health concerns. A method of specific, sensitive, and rapid detection of such bacteria is essential and important. This study presents a strategy that combines aptamer and antibiotic-based dual recognition units with magnetic enrichment and fluorescent detection to achieve specific and sensitive quantification of SA in authentic specimens and in the presence of much higher concentrations of other bacteria. Aptamer-coated magnetic beads (Apt-MB) were employed for specific capture of SA. Vancomycin-stabilized fluorescent gold nanoclusters (AuNCs@Van) were prepared by a simple one-step process and used for sensitive quantification of SA in the range of 32-10(8) cfu/mL with the detection limit of 16 cfu/mL via a fluorescence intensity measurement. And using this strategy, about 70 cfu/mL of SA in complex samples (containing 3 × 10(8) cfu/mL of other different contaminated bacteria) could be successfully detected. In comparison to prior studies, the developed strategy here not only simplifies the preparation procedure of the fluorescent probes (AuNCs@Van) to a great extent but also could sensitively quantify SA in the presence of much higher concentrations of other bacteria directly with good accuracy. Moreover, the aptamer and antibiotic used in this strategy are much less expensive and widely available compared to common-used antibodies, making it cost-effective. This general aptamer- and antibiotic-based dual recognition strategy, combined with magnetic enrichment and fluorescent detection of trace bacteria, shows great potential application in monitoring bacterial food contamination and infectious diseases.

  8. Preparation of Bio-beads and Their Atrazine Degradation Characteristics

    Institute of Scientific and Technical Information of China (English)

    BI Hai-tao; ZHANG Lan-ying; LIU Na; ZHU Bo-lin

    2011-01-01

    Screened atrazine-mineralizing bacterium-Pseudomonas W4 was embedded inside an improved PVAH3BO3 embedment matrix to make bio-beads to degrade atrazine. The atrazine degradation characteristics were studied. The preparation procedure of bio-beads was as follows: (1) preparing a mixture of 100, 12.5, 10, 1.5 and 1 g/L PVA, bentonite(Ca), activated carbon powder, sodium alginate and centrifuged Pseudomonas W4 bacterium, respectively; (2) the mixture was dropped into a gently stirred cross linker solution(pH=6.7) and cured at 10 ℃ for 24 h.The optimal atrazine degradation conditions by bio-beads were as follows: pH=7, the auxiliary carbon source was glucose, and the concentration of glucose was greater than 325 mg/L. The bio-beads demonstrated stronger tolerance ability than the free microorganism to the increase of PCBs, hydrogen ion and hydroxide ion. SEM images show the uniform distribution of the microorganism inside bio-beads and the porous cross-linked structure of bio-beads which provides excellent mass transfer capacity.

  9. Assessment of the Problems of Manual Automobile Tyre Bead ...

    African Journals Online (AJOL)

    The tyre-rim bead bond must be broken to carry out repairs on a failed automobile tyre. The use of the locally fabricated manual bead breaking equipment as it is being practiced today by commercial tyre repair artisans in Nigeria is characterized by drudgery. This article reports a study of the local manual bead breaking ...

  10. Growth and morphology of thermophilic dairy starters in alginate beads.

    Science.gov (United States)

    Lamboley, Laurence; St-Gelais, Daniel; Champagne, Claude P; Lamoureux, Maryse

    2003-06-01

    The aim of this research was to produce concentrated biomasses of thermophilic lactic starters using immobilized cell technology (ICT). Fermentations were carried out in milk using pH control with cells microentrapped in alginate beads. In the ICT fermentations, beads represented 17% of the weight. Some assays were carried out with free cells without pH control, in order to compare the ICT populations with those of classical starters. With Streptococcus thermophilus, overall populations in the fermentor were similar, but maximum bead population for (8.2 x 10(9) cfu/g beads) was 13 times higher than that obtained in a traditional starter (4.9 x 10(8) cfu/ml). For both Lactobacillus helveticus strains studied, immobilized-cell populations were about 3 x 10(9) cfu/g beads. Production of immobilized Lb. bulgaricus 210R strain was not possible, since no increases in viable counts occurred in beads. Therefore, production of concentrated cell suspension in alginate beads was more effective for S. thermophilus. Photomicrographs of cells in alginate beads demonstrated that, while the morphology of S. thermophilus remained unchanged during the ICT fermentation, immobilized cells of Lb. helveticus appeared wider. In addition, cells of Lb. bulgaricus were curved and elongated. These morphological changes would also impair the growth of immobilized lactobacilli.

  11. Generation of Internal-Image Functional Aptamers of Okadaic Acid via Magnetic-Bead SELEX

    Directory of Open Access Journals (Sweden)

    Chao Lin

    2015-12-01

    Full Text Available Okadaic acid (OA is produced by Dinophysis and Prorocentrum dinoflagellates and primarily accumulates in bivalves, and this toxin has harmful effects on consumers and operators. In this work, we first report the use of aptamers as novel non-toxic probes capable of binding to a monoclonal antibody against OA (OA-mAb. Aptamers that mimic the OA toxin with high affinity and selectivity were generated by the magnetic bead-assisted systematic evolution of ligands by exponential enrichment (SELEX strategy. After 12 selection rounds, cloning, sequencing and enzyme-linked immunosorbent assay (ELISA analysis, four candidate aptamers (O24, O31, O39, O40 were selected that showed high affinity and specificity for OA-mAb. The affinity constants of O24, O31, O39 and O40 were 8.3 × 108 M−1, 1.47 × 109 M−1, 1.23 × 109 M−1 and 1.05 × 109 M−1, respectively. Indirect competitive ELISA was employed to determine the internal-image function of the aptamers. The results reveal that O31 has a similar competitive function as free OA toxin, whereas the other three aptamers did not bear the necessary internal-image function. Based on the derivation of the curvilinear equation for OA/O31, the equation that defined the relationship between the OA toxin content and O31 was Y = 2.185X − 1.78. The IC50 of O31 was 3.39 ng·mL−1, which was close to the value predicted by the OA ELISA (IC50 = 4.4 ng·mL−1; the IC10 was 0.33 ng·mL−1. The above data provides strong evidence that internal-image functional aptamers could be applicable as novel probes in a non-toxic assay.

  12. Design of a transverse-flux permanent-magnet linear generator and controller for use with a free-piston stirling engine

    Science.gov (United States)

    Zheng, Jigui; Huang, Yuping; Wu, Hongxing; Zheng, Ping

    2016-07-01

    Transverse-flux with high efficiency has been applied in Stirling engine and permanent magnet synchronous linear generator system, however it is restricted for large application because of low and complex process. A novel type of cylindrical, non-overlapping, transverse-flux, and permanent-magnet linear motor(TFPLM) is investigated, furthermore, a high power factor and less process complexity structure research is developed. The impact of magnetic leakage factor on power factor is discussed, by using the Finite Element Analysis(FEA) model of stirling engine and TFPLM, an optimization method for electro-magnetic design of TFPLM is proposed based on magnetic leakage factor. The relation between power factor and structure parameter is investigated, and a structure parameter optimization method is proposed taking power factor maximum as a goal. At last, the test bench is founded, starting experimental and generating experimental are performed, and a good agreement of simulation and experimental is achieved. The power factor is improved and the process complexity is decreased. This research provides the instruction to design high-power factor permanent-magnet linear generator.

  13. A Monolithic CMOS Magnetic Hall Sensor with High Sensitivity and Linearity Characteristics.

    Science.gov (United States)

    Huang, Haiyun; Wang, Dejun; Xu, Yue

    2015-10-27

    This paper presents a fully integrated linear Hall sensor by means of 0.8 μm high voltage complementary metal-oxide semiconductor (CMOS) technology. This monolithic Hall sensor chip features a highly sensitive horizontal switched Hall plate and an efficient signal conditioner using dynamic offset cancellation technique. An improved cross-like Hall plate achieves high magnetic sensitivity and low offset. A new spinning current modulator stabilizes the quiescent output voltage and improves the reliability of the signal conditioner. The tested results show that at the 5 V supply voltage, the maximum Hall output voltage of the monolithic Hall sensor microsystem, is up to ±2.1 V and the linearity of Hall output voltage is higher than 99% in the magnetic flux density range from ±5 mT to ±175 mT. The output equivalent residual offset is 0.48 mT and the static power consumption is 20 mW.

  14. A Monolithic CMOS Magnetic Hall Sensor with High Sensitivity and Linearity Characteristics

    Directory of Open Access Journals (Sweden)

    Haiyun Huang

    2015-10-01

    Full Text Available This paper presents a fully integrated linear Hall sensor by means of 0.8 μm high voltage complementary metal-oxide semiconductor (CMOS technology. This monolithic Hall sensor chip features a highly sensitive horizontal switched Hall plate and an efficient signal conditioner using dynamic offset cancellation technique. An improved cross-like Hall plate achieves high magnetic sensitivity and low offset. A new spinning current modulator stabilizes the quiescent output voltage and improves the reliability of the signal conditioner. The tested results show that at the 5 V supply voltage, the maximum Hall output voltage of the monolithic Hall sensor microsystem, is up to ±2.1 V and the linearity of Hall output voltage is higher than 99% in the magnetic flux density range from ±5 mT to ±175 mT. The output equivalent residual offset is 0.48 mT and the static power consumption is 20 mW.

  15. Bead Collage: An Arts-Based Research Method

    Science.gov (United States)

    Kay, Lisa

    2013-01-01

    In this paper, "bead collage," an arts-based research method that invites participants to reflect, communicate and construct their experience through the manipulation of beads and found objects is explained. Emphasizing the significance of one's personal biography and experiences as a researcher, I discuss how my background as an…

  16. Fluctuations of cytoskeleton-bound microbeads-the effect of bead-receptor binding dynamics

    International Nuclear Information System (INIS)

    Metzner, C; Raupach, C; Mierke, C T; Fabry, B

    2010-01-01

    The cytoskeleton (CSK) of living cells is a crosslinked fiber network, subject to ongoing biochemical remodeling processes that can be visualized by tracking the spontaneous motion of CSK-bound microbeads. The bead motion is characterized by anomalous diffusion with a power-law time evolution of the mean square displacement (MSD), and can be described as a stochastic transport process with apparent diffusivity D and power-law exponent β: MSD ∼ D (t/t 0 ) β . Here we studied whether D and β change with the time that has passed after the initial bead-cell contact, and whether they are sensitive to bead coating (fibronectin, integrin antibodies, poly-L-lysine, albumin) and bead size (0.5-4.5 μm). The measurements are interpreted in the framework of a simple model that describes the bead as an overdamped particle coupled to the fluctuating CSK network by an elastic spring. The viscous damping coefficient characterizes the degree of bead internalization into the cell, and the spring constant characterizes the strength of the binding of the bead to the CSK. The model predicts distinctive signatures of the MSD that change with time as the bead couples more tightly to the CSK and becomes internalized. Experimental data show that the transition from the unbound to the tightly bound state occurs in an all-or-nothing manner. The time point of this transition shows considerable variability between individual cells (2-30 min) and depends on the bead size and bead coating. On average, this transition occurs later for smaller beads and beads coated with ligands that trigger the formation of adhesion complexes (fibronectin, integrin antibodies). Once the bead is linked to the CSK, however, the ligand type and bead size have little effect on the MSD. On longer timescales of several hours after bead addition, smaller beads are internalized into the cell more readily, leading to characteristic changes in the MSD that are consistent with increased viscous damping by the

  17. Prediction of bead area contact load at the tire-wheel interface using NASTRAN

    Science.gov (United States)

    Chen, C. H. S.

    1982-01-01

    The theoretical prediction of the bead area contact load at the tire wheel interface using NASTRAN is reported. The application of the linear code to a basically nonlinear problem results in excessive deformation of the structure and the tire-wheel contact conditions become impossible to achieve. A psuedo-nonlinear approach was adopted in which the moduli of the cord reinforced composite are increased so that the computed key deformations matched that of the experiment. Numerical results presented are discussed.

  18. Torque decomposition and control in an iron core linear permanent magnet motor.

    NARCIS (Netherlands)

    Overboom, T.T.; Smeets, J.P.C.; Stassen, J.M.; Jansen, J.W.; Lomonova, E.

    2012-01-01

    Abstract—This paper concerns the decomposition and control of the torque produced by an iron core linear permanent magnet motor. The proposed method is based on the dq0-decomposition of the three-phase currents using Park’s transformation. The torque is decomposed into a reluctance component and two

  19. Nu shifts in betatron oscillations from uniform perturbations in the presence of non-linear magnetic guide fields

    International Nuclear Information System (INIS)

    Crebbin, K.C.

    1985-05-01

    Uniform magnetic field perturbations cause a closed orbit distortion in a circular accelerator. If the magnetic guide field is non-linear these perturbations can also cause a Nu shift in the betatron oscillations. Such a shift in radial Nu values has been observed in the Bevalac while studying the low energy resonant extraction system. In the Bevalac, the radial perturbation comes from the quadrants being magnetically about 0.8% longer than 90 0 . The normal effect of this type of perturbation is a radial closed orbit shift and orbit distortion. The Nu shift, associated with this type of perturbation in the presence of a non-linear guide field, is discussed in this paper. A method of handling the non-linear n values is discussed as well as the mechanism for the associated Nu shift. Computer calculations are compared to measurements. 2 refs., 4 figs

  20. A novel single-phase flux-switching permanent magnet linear generator used for free-piston Stirling engine

    Science.gov (United States)

    Zheng, Ping; Sui, Yi; Tong, Chengde; Bai, Jingang; Yu, Bin; Lin, Fei

    2014-05-01

    This paper investigates a novel single-phase flux-switching permanent-magnet (PM) linear machine used for free-piston Stirling engines. The machine topology and operating principle are studied. A flux-switching PM linear machine is designed based on the quasi-sinusoidal speed characteristic of the resonant piston. Considering the performance of back electromotive force and thrust capability, some leading structural parameters, including the air gap length, the PM thickness, the ratio of the outer radius of mover to that of stator, the mover tooth width, the stator tooth width, etc., are optimized by finite element analysis. Compared with conventional three-phase moving-magnet linear machine, the proposed single-phase flux-switching topology shows advantages in less PM use, lighter mover, and higher volume power density.

  1. Elution of Clindamycin and Enrofloxacin From Calcium Sulfate Hemihydrate Beads In Vitro.

    Science.gov (United States)

    Phillips, Heidi; Boothe, Dawn M; Bennett, R Avery

    2015-11-01

    To compare the in vitro elution characteristics of clindamycin and enrofloxacin from calcium sulfate hemihydrate beads containing a single antibiotic, both antibiotics, and each antibiotic incubated in the same eluent well. Experimental in vitro study. Calcium sulfate hemihydrate beads were formed by mixing with clindamycin and/or enrofloxacin to create 4 study groups: (1) 160 mg clindamycin/10 beads; (2) 160 mg enrofloxacin/10 beads; (3) 160 mg clindamycin + 160 mg enrofloxacin/10 beads; and (4) 160 mg clindamycin/5 beads and 160 mg enrofloxacin/5 beads. Chains of beads were formed in triplicate and placed in 5 mL phosphate buffered saline (PBS; pH 7.4 and room temperature) with constant agitation. Antibiotic-conditioned PBS was sampled at 14 time points from 1 hour to 30 days. Clindamycin and enrofloxacin concentrations in PBS were determined using high-performance liquid chromatography. Eluent concentrations from clindamycin-impregnated beads failed to remain sufficiently above minimum inhibitory concentration (MIC) for common infecting bacteria over the study period. Enrofloxacin eluent concentrations remained sufficiently above MIC for common wound pathogens of dogs and cats and demonstrated an atypical biphasic release pattern. No significant differences in elution occurred as a result of copolymerization of the antibiotics into a single bead or from individual beads co-eluting in the same eluent well. Clindamycin-impregnated beads cannot be recommended for treatment of infection at the studied doses; however, use of enrofloxacin-impregnated beads may be justified when susceptible bacteria are cultured. © Copyright 2015 by The American College of Veterinary Surgeons.

  2. A NOVEL APPROACH TO SYNTHESIZE CHITOSAN BEADS CROSSLINKED BY EPICHLOROHYDRIN

    Institute of Scientific and Technical Information of China (English)

    WANG Yongjian; BAI Shu; SUN Yan

    2001-01-01

    The present investigation describes a novel method for preparing spherical chitosan particles based on crosslinking with epichlorohydrin. Certain amount of pre-crosslinking agent was added to form chitosan gels by traditional inverse phase suspension polymerization. Then the gels were crosslinked by epichlorohydrin at basic condition to obtain chitosan beads. The effects of reaction conditions, such as crosslinking time, the amount of crosslinking agent and the NaOtt concentration,on the physical properties of the chitosan beads were investigated. The beads were found to have more amino groups in the polymer chains than the beads crosslinked by glutaraldehyde. The capacity for copper ions is as high as 40mg/g. The beads have good mechanical strength and can be reused.

  3. A NOVEL APPROACH TO SYNTHESIZE CHITOSAN BEADS CROSSLINKED BY EPICHLOROHYDRIN

    Institute of Scientific and Technical Information of China (English)

    WANGYongjina; BAIShu; 等

    2001-01-01

    The present investigation describes a novel method for preparing spherical chitosan particles based on crosslinking with epichlorohydrin.Certain amount of pre-crosslinking agent was added to form chitosan gels by traditional inverse phase suspension polymerization.Then the gels were crosslinked by epichlorohydrin at basic condition to obtain chitosan beads.The effects of reaction conditions,such as crosslinking time,the amount of crosslinking agent and the NaOH concentration,on the physical properties of the chitosan beads were investigated.The beads were found to have more amino groups in the polymer chains than the beads crosslinked by glutaraldehyde.The capacity for copper ions in as high as 40mg/g,The beads have good mechanical strength and can be reused.

  4. Random glycopeptide bead libraries for seromic biomarker discovery

    DEFF Research Database (Denmark)

    Kracun, Stjepan Kresimir; Cló, Emiliano; Clausen, Henrik

    2010-01-01

    have developed a random glycopeptide bead library screening platform for detection of autoantibodies and other binding proteins. Libraries were build on biocompatible PEGA beads including a safety-catch C-terminal amide linker (SCAL) that allowed mild cleavage conditions (I(2)/NaBH(4) and TFA...... to other tumor glycoforms by on-bead enzymatic glycosylation reactions with recombinant glycosyltransferases. Hence, we have developed a high-throughput flexible platform for rapid discovery of O-glycopeptide biomarkers and the method has applicability in other types of assays such as lectin...

  5. Investigation of a tubular dual-stator flux-switching permanent-magnet linear generator for free-piston energy converter

    Science.gov (United States)

    Sui, Yi; Zheng, Ping; Tong, Chengde; Yu, Bin; Zhu, Shaohong; Zhu, Jianguo

    2015-05-01

    This paper describes a tubular dual-stator flux-switching permanent-magnet (PM) linear generator for free-piston energy converter. The operating principle, topology, and design considerations of the machine are investigated. Combining the motion characteristic of free-piston Stirling engine, a tubular dual-stator PM linear generator is designed by finite element method. Some major structural parameters, such as the outer and inner radii of the mover, PM thickness, mover tooth width, tooth width of the outer and inner stators, etc., are optimized to improve the machine performances like thrust capability and power density. In comparison with conventional single-stator PM machines like moving-magnet linear machine and flux-switching linear machine, the proposed dual-stator flux-switching PM machine shows advantages in higher mass power density, higher volume power density, and lighter mover.

  6. MODELING OF EQUIVALENT STIFFNESS OF A MAGNETIC SPRING OF VIBRATION EXCITER BASED ON COAXIAL-LINEAR MOTOR

    Directory of Open Access Journals (Sweden)

    G.M. Golenkov

    2015-12-01

    Full Text Available Purpose. The research of the influence of value and direction of current on the equivalent spring magnetic force based on coaxial-linear motor (CLM – MS. Methodology. We carried out investigation of the equivalent harshness of magnetic spring with determination of electromechanical propulsion performance characteristics by the methods of computer modeling and experimental research of physical model of CLM – MS. The modeling of magnetic spring of CLM – MS is carried out by the finite-element method. The challenge is met as an axisymmetric challenge in cylindrical co-ordinates in magnetostatic approach. The experimental investigattion of the propulsion performance characteristics of magnetic spring is carried out on the test bench. Results. After the computer modeling and the experimental investigation of the electromechanical propulsion performance characteristics of magnetic spring the expressions of equivalent stiffness coefficient depending on the current in winding are obtained. The results of computer modeling are confirmed experimentally. Originality. The determination of equivalent stiffness coefficient of magnetic spring of vibration exciter based on coaxial-linear motor. Practical value. The obtained determination of equivalent stiffness coefficient of magnetic spring may be used in process of designing of vibration machines with devices for change of natural oscillation frequency.

  7. Ionically crosslinked alginate–carboxymethyl cellulose beads for the delivery of protein therapeutics

    International Nuclear Information System (INIS)

    Kim, Min Sup; Park, Sang Jun; Gu, Bon Kang; Kim, Chun-Ho

    2012-01-01

    Highlights: ► We prepared Fe 3+ crosslinked alginate–carboxymethyl cellulose (AC) beads. ► Different surface and inner morphology of AC beads were observed on volume of CMC. ► AC beads showed minimum swelling degree in acidic condition. ► Protein release from AC beads was to control in gastrointestinal condition. - Abstract: We developed Fe 3+ -crosslinked alginate–carboxymethyl cellulose (AC) beads in various volume ratios by dropping an AC solution into a ferric chloride solution to form protein therapeutic carrier beads. Scanning electron microscopy revealed that the roughness and pore size of the crosslinked beads increased with the volume ratio of the carboxymethyl cellulose. Fourier transform-infrared analysis revealed the formation of a three-dimensional bonding structure between the anionic polymeric chains of AC and the Fe 3+ ions. The degree of swelling and the release profile of albumin from the beads were investigated under simulated gastrointestinal conditions (pH 1.2, 4.5, and 7.4). The Fe 3+ -crosslinked AC beads displayed different degrees of swelling and albumin release for the various AC volume ratios and under various pH conditions. An in vitro release test was used to monitor the controlled release of albumin from the AC beads under simulated gastrointestinal conditions over 24 h. The Fe 3+ -crosslinked AC beads protected and controlled the release of protein, demonstrating that such beads present a promising protein therapeutic carrier for the oral delivery.

  8. Rapid, highly sensitive detection of herpes simplex virus-1 using multiple antigenic peptide-coated superparamagnetic beads.

    Science.gov (United States)

    Ran, Ying-Fen; Fields, Conor; Muzard, Julien; Liauchuk, Viktoryia; Carr, Michael; Hall, William; Lee, Gil U

    2014-12-07

    A sensitive, rapid, and label free magnetic bead aggregation (MBA) assay has been developed that employs superparamagnetic (SPM) beads to capture, purify, and detect model proteins and the herpes simplex virus (HSV). The MBA assay is based on monitoring the aggregation state of a population of SPM beads using light scattering of individual aggregates. A biotin-streptavidin MBA assay had a femtomolar (fM) level sensitivity for analysis times less than 10 minutes, but the response of the assay becomes nonlinear at high analyte concentrations. A MBA assay for the detection of HSV-1 based on a novel peptide probe resulted in the selective detection of the virus at concentrations as low as 200 viral particles (vp) per mL in less than 30 min. We define the parameters that determine the sensitivity and response of the MBA assay, and the mechanism of enhanced sensitivity of the assay for HSV. The speed, relatively low cost, and ease of application of the MBA assay promise to make it useful for the identification of viral load in resource-limited and point-of-care settings where molecular diagnostics cannot be easily implemented.

  9. exploring traditional glass bead making techniques in jewellery

    African Journals Online (AJOL)

    User

    Glass bead making techniques and their mass production will help the individual ... communicate cultural values in a symbolic lan- guage which ..... Surface of most of the new beads were rough ... tourism potential to be developed further to.

  10. Magnetic Actuation of Biological Systems

    Science.gov (United States)

    Lauback, Stephanie D.

    Central to the advancement of many biomedical and nanotechnology capabilities is the capacity to precisely control the motion of micro and nanostructures. These applications range from single molecule experiments to cell isolation and separation, to drug delivery and nanomachine manipulation. This dissertation focuses on actuation of biological micro- and nano-entities through the use of weak external magnetic fields, superparamagnetic beads, and ferromagnetic thin films. The magnetic platform presents an excellent method for actuation of biological systems due to its ability to directly control the motion of an array of micro and nanostructures in real-time with calibrated picoNewton forces. The energy landscape of two ferromagnetic thin film patterns (disks and zigzag wires) is experimentally explored and compared to corresponding theoretical models to quantify the applied forces and trajectories of superparamagnetic beads due to the magnetic traps. A magnetic method to directly actuate DNA nanomachines in real-time with nanometer resolution and sub-second response times using micromagnetic control was implemented through the use of stiff DNA micro-levers which bridged the large length scale mismatch between the micro-actuator and the nanomachine. Compared to current alternative methods which are limited in the actuation speeds and the number of reconfiguration states of DNA constructs, this magnetic approach enables fast actuation (˜ milliseconds) and reconfigurable conformations achieved through a continuous range of finely tuned steps. The system was initially tested through actuation of the stiff arm tethered to the surface, and two prototype DNA nanomachines (rotor and hinge) were successfully actuated using the stiff mechanical lever. These results open new possibilities in the development of functional robotic systems at the molecular scale. In exploiting the use of DNA stiff levers, a new technique was also developed to investigate the emergence of the

  11. Chinese and Venetian glass beads excavated from Fais Island in Micronesia

    International Nuclear Information System (INIS)

    Intoh, Michiko

    1997-01-01

    Full text: Over 830 glass beads were excavated from a late prehistoric cemetery site on Fais Island in the Caroline Islands, Micronesia In one of the 13 excavated burials a young woman had more that 310 glass beads around her wrist. Bone collagen from this burial was dated by AMS to 387 + 64 BP. The associated glass beads were classified into three groups based on colour and size. A sample from each group was examined for evidence of manufacturing technique. The chemical composition was determined using an X-ray microanalyser. The first group consisted of more than 300 pale green, transparent glass beads which are less than 2 mm in diameter. The chemical composition is high in PbO (75.22%) while low in MgO. Such a high lead content is characteristic of Chinese glass. The manufacturing technique could not be determined because the surfaces were too eroded. The second group contains several yellow, translucent glass beads. The chemical composition is also high in PbO (54.8%) and low in MgO. The beads were made by winding. The combination of winding and high lead strongly indicates that the beads were made in China. The third group had only one white, translucent glass bead. It has particular white stripes which suggest that it is a 'gooseberry' bead which was made in Venice between the sixteenth and eighteenth centuries. In conclusion, both Chinese and Venetian glass beads co-existed on Fais Island around the time of European contact. They are likely to have been brought in from an area which had access to both beads. Island South-East Asia is tentatively considered to be the source area

  12. Cooling Rates of Lunar Volcanic Glass Beads

    Science.gov (United States)

    Hui, Hejiu; Hess, Kai-Uwe; Zhang, Youxue; Peslier, Anne; Lange, Rebecca; Dingwell, Donald; Neal, Clive

    2016-01-01

    It is widely accepted that the Apollo 15 green and Apollo 17 orange glass beads are of volcanic origin. The diffusion profiles of volatiles in these glass beads are believed to be due to degassing during eruption (Saal et al., 2008). The degree of degassing depends on the initial temperature and cooling rate. Therefore, the estimations of volatiles in parental magmas of lunar pyroclastic deposits depend on melt cooling rates. Furthermore, lunar glass beads may have cooled in volcanic environments on the moon. Therefore, the cooling rates may be used to assess the atmospheric condition in an early moon, when volcanic activities were common. The cooling rates of glasses can be inferred from direct heat capacity measurements on the glasses themselves (Wilding et al., 1995, 1996a,b). This method does not require knowledge of glass cooling environments and has been applied to calculate the cooling rates of natural silicate glasses formed in different terrestrial environments. We have carried out heat capacity measurements on hand-picked lunar glass beads using a Netzsch DSC 404C Pegasus differential scanning calorimeter at University of Munich. Our preliminary results suggest that the cooling rate of Apollo 17 orange glass beads may be 12 K/min, based on the correlation between temperature of the heat capacity curve peak in the glass transition range and glass cooling rate. The results imply that the parental magmas of lunar pyroclastic deposits may have contained more water initially than the early estimations (Saal et al., 2008), which used higher cooling rates, 60-180 K/min in the modeling. Furthermore, lunar volcanic glass beads could have been cooled in a hot gaseous medium released from volcanic eruptions, not during free flight. Therefore, our results may shed light on atmospheric condition in an early moon.

  13. Transition metal modified bulk BiFeO3 with improved magnetization and linear magneto-electric coupling

    International Nuclear Information System (INIS)

    Puli, Venkata Sreenivas; Kumar, A.; Panwar, N.; Panwar, I.C.; Katiyar, R.S.

    2011-01-01

    Highlights: → Present composition (Bi 0.9 Sm 0.10 Fe 0.95 Co 0.05 O 3 (BSFCO) have shown very high magnetization compared to parent BFO. → The magnetic hysteresis loops are well saturated with high saturation magnetization 2.89 emu/gm (unpoled and unleached) and 2.18 emu/gm (poled and unleached) respectively. → Converse ME coupling were found 0.8e-10 s m -1 (H||E) and 0.6-0.8 x 10 -10 s m -1 (H-perpendicular E) which are better than the single phase multiferroic obeying linear ME coupling. - Abstract: At present BiFeO 3 (BFO) is the most attractive and sole example, which possesses low magnetization value, high leakage current and low polarization in ceramic form. Single-phase room temperature multiferroics are rare in nature. This paper deals with the improved magnetic and observed linear magneto-electric coupling in Co and Sm co-doped BiFeO 3 ceramics synthesized by sol-gel process at low temperature ∼600 deg. C. As synthesized Bi 0.9 Sm 0.10 Fe 0.95 Co 0.05 O 3 (BSFCO) showed high impurities phases (20%) over wide range of calcination temperatures. Impurity phases reduced drastically from 20% to 5% after leaching with nitric acid. However the electrical and the magnetic properties were almost the same for both phases. Well-defined magnetic hysteresis with high magnetic moment was found at room temperature. Ferroelectric polarization studies demonstrated similar values and shape as reported in literature for the pure bulk BFO. Linear magneto-electric (ME) coupling and weak ME coefficient (α) ∼ 0.6 e-10 s m -1 were observed in the co-doped BFO. The origin of the strong ferromagnetic property in our samples may be due to the presence of rare earth and transition metal ions at the lattice sites of BFO or due to impurity phase, since we have not seen any change in magnetization with reduction of impurity phase the later effect is more unlikely.

  14. On-chip immunomagnetic separation of bacteria by in-flow dynamic manipulation of paramagnetic beads

    Science.gov (United States)

    Ahmed, Shakil; Noh, Jong Wook; Hoyland, James; de Oliveira Hansen, Roana; Erdmann, Helmut; Rubahn, Horst-Günter

    2016-11-01

    Every year, millions of people all over the world fall ill due to the consumption of unsafe food, where consumption of contaminated and spoiled animal origin product is the main cause for diseases due to bacterial growth. This leads to an intense need for efficient methods for detection of food-related bacteria. In this work, we present a method for integration of immunomagnetic separation of bacteria into microfluidic technology by applying an alternating magnetic field, which manipulates the paramagnetic beads into a sinusoidal path across the whole microchannel, increasing the probability for bacteria capture. The optimum channel geometry, flow rate and alternating magnetic field frequency were investigated, resulting in a capture efficiency of 68 %.

  15. Linear response theory for magnetic Schrodinger operators in disordered media

    CERN Document Server

    Bouclet, J M; Klein, A; Schenker, J

    2004-01-01

    We justify the linear response theory for an ergodic Schrodinger operator with magnetic field within the non-interacting particle approximation, and derive a Kubo formula for the electric conductivity tensor. To achieve that, we construct suitable normed spaces of measurable covariant operators where the Liouville equation can be solved uniquely. If the Fermi level falls into a region of localization, we recover the well-known Kubo-Streda formula for the quantum Hall conductivity at zero temperature.

  16. Transarterial chemoembolization with drug-eluting beads in hepatocellular carcinoma

    Science.gov (United States)

    Nam, Hee Chul; Jang, Bohyun; Song, Myeong Jun

    2016-01-01

    Transarterial chemoembolization (TACE) is a widely used standard treatment for patients with hepatocellular carcinoma (HCC) who are not suitable candidates for curative treatments. The rationale for TACE is that intra-arterial chemotherapy using lipiodol and chemotherapeutic agents, followed by selective vascular embolization, results in a strong cytotoxic effect as well as ischemia (conventional TACE). Recently, drug-eluting beads (DC Beads®) have been developed for transcatheter treatment of HCC to deliver higher doses of the chemotherapeutic agent and to prolong contact time with the tumor. DC Beads® can actively sequester doxorubicin hydrochloride from solution and release it in a controlled sustained fashion. Treatment with DC Beads® substantially reduced the amount of chemotherapeutic agent that reached the systemic circulation compared with conventional, lipiodol-based regimens, significantly reducing drug-related adverse events. In this article, we describe the treatment response, survival, and safety of TACE used with drug-eluting beads for the treatment of HCC and discuss future therapeutic possibilities. PMID:27833376

  17. Pole-shape optimization of permanent-magnet linear synchronous motor for reduction of thrust ripple

    Energy Technology Data Exchange (ETDEWEB)

    Tavana, Nariman Roshandel, E-mail: nroshandel@ee.iust.ac.i [Department of Electrical Engineering, Iran University of Science and Technology, Narmak, Tehran 16846-13114 (Iran, Islamic Republic of); Shoulaie, Abbas, E-mail: shoulaie@iust.ac.i [Department of Electrical Engineering, Iran University of Science and Technology, Narmak, Tehran 16846-13114 (Iran, Islamic Republic of)

    2011-01-15

    In this paper, we have used magnet arc shaping technique in order to improve the performance of permanent-magnet linear synchronous motor (PMLSM). At first, a detailed analytical modeling based on Maxwell equations is presented for the analysis and design of PMLSM with the arc-shaped magnetic poles (ASMPs). Then the accuracy of presented method is verified by finite-element method. Very close agreement between the analytical and finite-element results shows the effectiveness of the proposed method. Finally, a magnet shape design is carried out based on the analytical method to enhance the motor developed thrust. Pertinent evaluations on the optimal design performance demonstrate that shape optimization leads to a design with extra low thrust ripple.

  18. Pole-shape optimization of permanent-magnet linear synchronous motor for reduction of thrust ripple

    International Nuclear Information System (INIS)

    Tavana, Nariman Roshandel; Shoulaie, Abbas

    2011-01-01

    In this paper, we have used magnet arc shaping technique in order to improve the performance of permanent-magnet linear synchronous motor (PMLSM). At first, a detailed analytical modeling based on Maxwell equations is presented for the analysis and design of PMLSM with the arc-shaped magnetic poles (ASMPs). Then the accuracy of presented method is verified by finite-element method. Very close agreement between the analytical and finite-element results shows the effectiveness of the proposed method. Finally, a magnet shape design is carried out based on the analytical method to enhance the motor developed thrust. Pertinent evaluations on the optimal design performance demonstrate that shape optimization leads to a design with extra low thrust ripple.

  19. TU-H-BRA-02: The Physics of Magnetic Field Isolation in a Novel Compact Linear Accelerator Based MRI-Guided Radiation Therapy System

    Energy Technology Data Exchange (ETDEWEB)

    Low, D [UCLA, Los Angeles, CA (United States); Mutic, S [Washington University School of Medicine, Saint Louis, MO (United States); Shvartsman, S; Chmielewski, T; Fought, G; Sharma, A; Dempsey, J [ViewRay, Inc., Oakwood Village, OH (United States)

    2016-06-15

    Purpose: To develop a method for isolating the MRI magnetic field from field-sensitive linear accelerator components at distances close to isocenter. Methods: A MRI-guided radiation therapy system has been designed that integrates a linear accelerator with simultaneous MR imaging. In order to accomplish this, the magnetron, port circulator, radiofrequency waveguide, gun driver, and linear accelerator needed to be placed in locations with low magnetic fields. The system was also required to be compact, so moving these components far from the main magnetic field and isocenter was not an option. The magnetic field sensitive components (exclusive of the waveguide) were placed in coaxial steel sleeves that were electrically and mechanically isolated and whose thickness and placement were optimized using E&M modeling software. Six sets of sleeves were placed 60° apart, 85 cm from isocenter. The Faraday effect occurs when the direction of propagation is parallel to the magnetic RF field component, rotating the RF polarization, subsequently diminishing RF power. The Faraday effect was avoided by orienting the waveguides such that the magnetic field RF component was parallel to the magnetic field. Results: The magnetic field within the shields was measured to be less than 40 Gauss, significantly below the amount needed for the magnetron and port circulator. Additional mu-metal was employed to reduce the magnetic field at the linear accelerator to less than 1 Gauss. The orientation of the RF waveguides allowed the RT transport with minimal loss and reflection. Conclusion: One of the major challenges in designing a compact linear accelerator based MRI-guided radiation therapy system, that of creating low magnetic field environments for the magnetic-field sensitive components, has been solved. The measured magnetic fields are sufficiently small to enable system integration. This work supported by ViewRay, Inc.

  20. TU-H-BRA-02: The Physics of Magnetic Field Isolation in a Novel Compact Linear Accelerator Based MRI-Guided Radiation Therapy System

    International Nuclear Information System (INIS)

    Low, D; Mutic, S; Shvartsman, S; Chmielewski, T; Fought, G; Sharma, A; Dempsey, J

    2016-01-01

    Purpose: To develop a method for isolating the MRI magnetic field from field-sensitive linear accelerator components at distances close to isocenter. Methods: A MRI-guided radiation therapy system has been designed that integrates a linear accelerator with simultaneous MR imaging. In order to accomplish this, the magnetron, port circulator, radiofrequency waveguide, gun driver, and linear accelerator needed to be placed in locations with low magnetic fields. The system was also required to be compact, so moving these components far from the main magnetic field and isocenter was not an option. The magnetic field sensitive components (exclusive of the waveguide) were placed in coaxial steel sleeves that were electrically and mechanically isolated and whose thickness and placement were optimized using E&M modeling software. Six sets of sleeves were placed 60° apart, 85 cm from isocenter. The Faraday effect occurs when the direction of propagation is parallel to the magnetic RF field component, rotating the RF polarization, subsequently diminishing RF power. The Faraday effect was avoided by orienting the waveguides such that the magnetic field RF component was parallel to the magnetic field. Results: The magnetic field within the shields was measured to be less than 40 Gauss, significantly below the amount needed for the magnetron and port circulator. Additional mu-metal was employed to reduce the magnetic field at the linear accelerator to less than 1 Gauss. The orientation of the RF waveguides allowed the RT transport with minimal loss and reflection. Conclusion: One of the major challenges in designing a compact linear accelerator based MRI-guided radiation therapy system, that of creating low magnetic field environments for the magnetic-field sensitive components, has been solved. The measured magnetic fields are sufficiently small to enable system integration. This work supported by ViewRay, Inc.

  1. Magnetic corrections to π -π scattering lengths in the linear sigma model

    Science.gov (United States)

    Loewe, M.; Monje, L.; Zamora, R.

    2018-03-01

    In this article, we consider the magnetic corrections to π -π scattering lengths in the frame of the linear sigma model. For this, we consider all the one-loop corrections in the s , t , and u channels, associated to the insertion of a Schwinger propagator for charged pions, working in the region of small values of the magnetic field. Our calculation relies on an appropriate expansion for the propagator. It turns out that the leading scattering length, l =0 in the S channel, increases for an increasing value of the magnetic field, in the isospin I =2 case, whereas the opposite effect is found for the I =0 case. The isospin symmetry is valid because the insertion of the magnetic field occurs through the absolute value of the electric charges. The channel I =1 does not receive any corrections. These results, for the channels I =0 and I =2 , are opposite with respect to the thermal corrections found previously in the literature.

  2. A Non-Linear Force-Free Field Model for the Evolving Magnetic Structure of Solar Filaments

    Science.gov (United States)

    Mackay, Duncan H.; van Ballegooijen, A. A.

    2009-12-01

    In this paper the effect of a small magnetic element approaching the main body of a solar filament is considered through non-linear force-free field modeling. The filament is represented by a series of magnetic dips. Once the dips are calculated, a simple hydrostatic atmosphere model is applied to determine which structures have sufficient column mass depth to be visible in Hα. Two orientations of the bipole are considered, either parallel or anti-parallel to the overlying arcade. The magnetic polarity that lies closest to the filament is then advected towards the filament. Initially for both the dominant and minority polarity advected elements, right/left bearing barbs are produced for dextral/sinsitral filaments. The production of barbs due to dominant polarity elements is a new feature. In later stages the filament breaks into two dipped sections and takes a highly irregular, non-symmetrical form with multiple pillars. The two sections are connected by field lines with double dips even though the twist of the field is less than one turn. Reconnection is not found to play a key role in the break up of the filament. The non-linear force-free fields produce very different results to extrapolated linear-force free fields. For the cases considered here the linear force-free field does not produce the break up of the filament nor the production of barbs as a result of dominant polarity elements.

  3. A comparison of least squares linear regression and measurement error modeling of warm/cold multipole correlation in SSC prototype dipole magnets

    International Nuclear Information System (INIS)

    Pollock, D.; Kim, K.; Gunst, R.; Schucany, W.

    1993-05-01

    Linear estimation of cold magnetic field quality based on warm multipole measurements is being considered as a quality control method for SSC production magnet acceptance. To investigate prediction uncertainties associated with such an approach, axial-scan (Z-scan) magnetic measurements from SSC Prototype Collider Dipole Magnets (CDM's) have been studied. This paper presents a preliminary evaluation of the explanatory ability of warm measurement multipole variation on the prediction of cold magnet multipoles. Two linear estimation methods are presented: least-squares regression, which uses the assumption of fixed independent variable (xi) observations, and the measurement error model, which includes measurement error in the xi's. The influence of warm multipole measurement errors on predicted cold magnet multipole averages is considered. MSD QA is studying warm/cold correlation to answer several magnet quality control questions. How well do warm measurements predict cold (2kA) multipoles? Does sampling error significantly influence estimates of the linear coefficients (slope, intercept and residual standard error)? Is estimation error for the predicted cold magnet average small compared to typical variation along the Z-Axis? What fraction of the multipole RMS tolerance is accounted for by individual magnet prediction uncertainty?

  4. Polymerized serum albumin beads for use as slow-release adjuvants

    International Nuclear Information System (INIS)

    Martin, M.E.D.

    1987-02-01

    Experimental vaccines have been made by covalently bonding virus particles into polymerized rabbit serum albumin beads. Using Nodamura virus as a model antigen, these model vaccines induced specific humoral antibody production, comparable with that achieved using Freund's adjuvants. Virus specific antibodies were also induced when Nodamura virus was covalently attached to the bead surface using different crosslinkers. However, when poliovirus type 2 (Sabin strain) was polymerized into beads, the levels of neutralizing antibodies were insignificant compared with control aqueous vaccines. The synthetic immunostimulator, muramyl dipeptide, was included with bead vaccines in an attempt to potentiate the immune response. Immunostimulation is achieved by a slow release of antigen coinciding with the gradual breakdown of bead structure. Methods used include radio-iodination and radioimmunoassay. 65 figs., 6 tabs., 173 refs

  5. Manipulation of Superparamagnetic Beads on Patterned Exchange-Bias Layer Systems for Biosensing Applications

    Directory of Open Access Journals (Sweden)

    Arno Ehresmann

    2015-11-01

    Full Text Available A technology platform based on a remotely controlled and stepwise transport of an array arrangement of superparamagnetic beads (SPB for efficient molecular uptake, delivery and accumulation in the context of highly specific and sensitive analyte molecule detection for the application in lab-on-a-chip devices is presented. The near-surface transport of SPBs is realized via the dynamic transformation of the SPBs’ magnetic potential energy landscape above a magnetically stripe patterned Exchange-Bias (EB thin film layer systems due to the application of sub-mT external magnetic field pulses. In this concept, the SPB velocity is dramatically influenced by the magnitude and gradient of the magnetic field landscape (MFL above the magnetically stripe patterned EB substrate, the SPB to substrate distance, the magnetic properties of both the SPBs and the EB layer system, respectively, as well as by the properties of the external magnetic field pulses and the surrounding fluid. The focus of this review is laid on the specific MFL design in EB layer systems via light-ion bombardment induced magnetic patterning (IBMP. A numerical approach is introduced for the theoretical description of the MFL in comparison to experimental characterization via scanning Hall probe microscopy. The SPB transport mechanism will be outlined in terms of the dynamic interplay between the EB substrate’s MFL and the pulse scheme of the external magnetic field.

  6. Manipulation of Superparamagnetic Beads on Patterned Exchange-Bias Layer Systems for Biosensing Applications.

    Science.gov (United States)

    Ehresmann, Arno; Koch, Iris; Holzinger, Dennis

    2015-11-13

    A technology platform based on a remotely controlled and stepwise transport of an array arrangement of superparamagnetic beads (SPB) for efficient molecular uptake, delivery and accumulation in the context of highly specific and sensitive analyte molecule detection for the application in lab-on-a-chip devices is presented. The near-surface transport of SPBs is realized via the dynamic transformation of the SPBs' magnetic potential energy landscape above a magnetically stripe patterned Exchange-Bias (EB) thin film layer systems due to the application of sub-mT external magnetic field pulses. In this concept, the SPB velocity is dramatically influenced by the magnitude and gradient of the magnetic field landscape (MFL) above the magnetically stripe patterned EB substrate, the SPB to substrate distance, the magnetic properties of both the SPBs and the EB layer system, respectively, as well as by the properties of the external magnetic field pulses and the surrounding fluid. The focus of this review is laid on the specific MFL design in EB layer systems via light-ion bombardment induced magnetic patterning (IBMP). A numerical approach is introduced for the theoretical description of the MFL in comparison to experimental characterization via scanning Hall probe microscopy. The SPB transport mechanism will be outlined in terms of the dynamic interplay between the EB substrate's MFL and the pulse scheme of the external magnetic field.

  7. Design and analysis of linear fault-tolerant permanent-magnet vernier machines.

    Science.gov (United States)

    Xu, Liang; Ji, Jinghua; Liu, Guohai; Du, Yi; Liu, Hu

    2014-01-01

    This paper proposes a new linear fault-tolerant permanent-magnet (PM) vernier (LFTPMV) machine, which can offer high thrust by using the magnetic gear effect. Both PMs and windings of the proposed machine are on short mover, while the long stator is only manufactured from iron. Hence, the proposed machine is very suitable for long stroke system applications. The key of this machine is that the magnetizer splits the two movers with modular and complementary structures. Hence, the proposed machine offers improved symmetrical and sinusoidal back electromotive force waveform and reduced detent force. Furthermore, owing to the complementary structure, the proposed machine possesses favorable fault-tolerant capability, namely, independent phases. In particular, differing from the existing fault-tolerant machines, the proposed machine offers fault tolerance without sacrificing thrust density. This is because neither fault-tolerant teeth nor the flux-barriers are adopted. The electromagnetic characteristics of the proposed machine are analyzed using the time-stepping finite-element method, which verifies the effectiveness of the theoretical analysis.

  8. Magnetometry of buried layers—Linear magnetic dichroism and spin detection in angular resolved hard X-ray photoelectron spectroscopy

    International Nuclear Information System (INIS)

    Gloskovskii, Andrei; Stryganyuk, Gregory; Fecher, Gerhard H.; Felser, Claudia; Thiess, Sebastian; Schulz-Ritter, Heiko; Drube, Wolfgang; Berner, Götz; Sing, Michael; Claessen, Ralph; Yamamoto, Masafumi

    2012-01-01

    Highlights: ► Newly commissioned HAXPES instrument at P09 beamline of the PETRA III ring at DESY. ► We report HAXPES studies on buried magnetic nanolayers in a multi-layer sample. ► Linear magnetic dichroism of photoelectrons from buried CoFe–Ir 78 Mn 22 layers. ► Spin-resolved HAXPES measurements on buried magnetic multilayers using Mott detector. - Abstract: The electronic properties of buried magnetic nano-layers were studied using the linear magnetic dichroism in the angular distribution of photoemitted Fe, Co, and Mn 2p electrons from a CoFe–Ir 78 Mn 22 multi-layered sample. The buried layers were probed using hard X-ray photoelectron spectroscopy, HAXPES, at the undulator beamline P09 of the 3rd generation storage ring PETRA III. The results demonstrate that this magnetometry technique can be used as a sensitive element specific probe for magnetic properties suitable for application to buried ferromagnetic and antiferromagnetic magnetic materials and multilayered spintronics devices. Using the same instrument, spin-resolved Fe 2p HAXPES spectra were obtained from the buried layer with good signal quality.

  9. Effect of formulation of alginate beads on their mechanical behavior and stiffness

    Institute of Scientific and Technical Information of China (English)

    Eng-Seng Chan; Tek-Kaun Lim; Wan-Ping Voo; Ravindra Pogaku; Beng Ti Tey; Zhibing Zhang

    2011-01-01

    The aim of this work was to determine the effect of formulation of alginate beads on their mechanical behavior and stiffness when compressed at high speed. The alginate beads were formulated using different types and concentrations of alginate and gelling cations and were produced using an extrusiondripping method. Single wet beads were compressed at a speed of 40 mm/min, and their elastic limits were investigated, and the corresponding force versus displacement data were obtained. The Young's moduli of the beads were determined from the force versus displacement data using the Hertz's contact mechanics theory. The alginate beads were found to exhibit plastic behavior when they were compressed beyond 50% with the exception of copper-alginate beads for which yield occured at lower deformation.Alginate beads made of higher guluronic acid contents and gelling cations of higher chemical affinity were found to have greater stiffness. Increasing the concentration of alginate and gelling ions also generated a similar effect. At such a compression speed, the values of Young's modulus of the beads were found to be in the range between 250 and 900 kPa depending on the bead formulation.

  10. Optimization of weld bead geometry of MS plate

    Indian Academy of Sciences (India)

    The considered specimen was checked to harmonize the optimum setting between input factors, for example, welding current, open circuit voltage, and thickness of plate, with respect to obtaining prosperous weld strength as well as bead geometry quality characteristics, for example, tensile strength, bead width, ...

  11. Processes Leading to Beaded Channels Formation in Central Yakutia

    Science.gov (United States)

    Tarbeeva, A. M.; Lebedeva, L.; Efremov, V. S.; Krylenko, I. V.; Surkov, V. V.

    2017-12-01

    Beaded channels, consisting of deepened and widened pools and connecting narrow runs, are common fluvial forms in permafrost regions. Recent studies have shown that beaded channels are very important for connecting alluvial rivers with headwater lakes allowing fish passage and foraging habitats, as well as regulating river runoff. Beaded channels are known as typical thermokarst landforms; however, there is no evidence of their origin and formative processes. Geomorphological analyzes of beaded channels have been completed in several permafrost regions including field observations of Shestakovka River in Central Yakutia. The study aims to recognize the modern exogenic processes and formative mechanisms of beaded river channels. We show that beaded channel of Shestakovka River form in the perennially frozen sand with low ice content, leading us to hypothesize that thermokarst is not the main process of formation. Due to the significant volume of water, the pools don't freeze over entirely during winters, even under harsh climatic conditions. As a result, lenses of pressurized water remain under surface ice underlain by perennially thawed sediments. The presence of thawed sediments under the pools and frozen sediments under the runs leads to uneven thermoerosion of the riverbed during floods, providing the beaded form of the channel. In addition, freezing of pools during winter leads to pressure increasing under ice cover and formation of ice mounds, which crack several times during winter leading to disturbance of riverbanks. Many 1st to 3rd order streams have a specific transitional meandering-to-beaded form resembling the shape of unconfined meandering rivers, but consisting of pools and runs. However, such channels exhibit no evidences of present-day erosion of concave banks and sediment accumulation at the convex banks as typically being observed in normally meandering rivers. Such forms of channels indicates that their formation occurred by the greater channel

  12. Removal of Uranium from Aqueous Solution by Alginate Beads

    Directory of Open Access Journals (Sweden)

    Jing Yu

    2017-04-01

    Full Text Available The adsorption of uranium (VI by calcium alginate beads was examined by batch experiments. The effects of environmental conditions on U (VI adsorption were studied, including contact time, pH, initial concentration of U (VI, and temperature. The alginate beads were characterized by using scanning electron microscopy, transmission electron microscopy, X-ray photoelectron spectroscopy, and Fourier transform infrared spectroscopy. Fourier transform infrared spectra indicated that hydroxyl and alkoxy groups are present at the surface of the beads. The experimental results showed that the adsorption of U (VI by alginate beads was strongly dependent on pH, the adsorption increased at pH 3∼7, then decreased at pH 7∼9. The adsorption reached equilibrium within 2 minutes. The adsorption kinetics of U (VI onto alginate beads can be described by a pseudo first-order kinetic model. The adsorption isotherm can be described by the Redlich-Peterson model, and the maximum adsorption capacity was 237.15 mg/g. The sorption process is spontaneous and has an exothermic reaction.

  13. Removal of uranium from aqueous solution by aliginate beads

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Jing; Wang, Jian Long [Collaborative Innovation Center for Advanced Nuclear Energy Technology, INET, Tsinghua University, Beijing (China); Jiang, Yizhou [Northwest Institute of Nuclear Technology, Xian (China)

    2017-04-15

    The adsorption of uranium (VI) by calcium alginate beads was examined by batch experiments. The effects of environmental conditions on U (VI) adsorption were studied, including contact time, pH, initial concentration of U (VI), and temperature. The alginate beads were characterized by using scanning electron microscopy, transmission electron microscopy, X-ray photoelectron spectroscopy, and Fourier transform infrared spectroscopy. Fourier transform infrared spectra indicated that hydroxyl and alkoxy groups are present at the surface of the beads. The experimental results showed that the adsorption of U (VI) by alginate beads was strongly dependent on pH, the adsorption increased at pH 3∼7, then decreased at pH 7∼9. The adsorption reached equilibrium within 2 minutes. The adsorption kinetics of U (VI) onto alginate beads can be described by a pseudo first-order kinetic model. The adsorption isotherm can be described by the Redlich-Peterson model, and the maximum adsorption capacity was 237.15 mg/g. The sorption process is spontaneous and has an exothermic reaction.

  14. Oxytetracycline removal from water by novel microbial embedding gel beads

    Science.gov (United States)

    Wu, Nan; Pan, Peng; Zeng, Ming; Wang, Wei; Xu, Chenshan; Zhang, Zongpeng; Liu, Xinyuan; Wang, Yichao

    2018-01-01

    As a common antibiotic in aquatic environment, excessive oxytetracycline (OTC) is urgent to be removed due to its great biological toxicity. Compared with the traditional activated sludge, microbial embedding can enhance the treating efficiency. In this study, novel microbial embedding gel beads were produced with the additional agent of cyclodextrin (CD). Results show that CD could increase the mass transfer of OTC into gel beads, possibly because of its strong affinity for organic matters. In terms of OTC biodegradation, gel beads with CD were comparable to gel beads without CD, while the former’s sucrose removal efficiency was higher than the latter. The biodegradation of OTC only occurred in the presence of sucrose. The respiration test also confirmed these findings. Overall, the produced novel gel beads modified with CD could improve the removal performance of OTC.

  15. A study on stable levitation of permanent magnet transportation system with coreless linear synchronous motor

    Energy Technology Data Exchange (ETDEWEB)

    Hiwaki, H [Dept. of Electrical and Electronic Engineering, Musashi Inst. of Technology, Tokyo (Japan); Watada, M [Dept. of Electrical and Electronic Engineering, Musashi Inst. of Technology, Tokyo (Japan); Torii, S [Dept. of Electrical and Electronic Engineering, Musashi Inst. of Technology, Tokyo (Japan); Ebihara, D [Dept. of Electrical and Electronic Engineering, Musashi Inst. of Technology, Tokyo (Japan)

    1996-12-31

    In the permanent magnet levitation system, it is impossible to stabilize the motion of the vehicle in both levitation and guidance directions only by permanent magnet. Therefore, the authors proposed the combined system of permanent magnet for levitation and coreless linear synchronous motor (coreless LSM). To design the coreless coils for LSM, the method to calculate the spring coefficient between coreless coil and permanent magnet for LSM is shown. By using this method, the spring coefficients of the three coil arrangements are compared and coreless coil is designed. Furthermore, the authors showed the possibility of stabilizing the motion of the levitation system with coreless LSM. (orig.)

  16. Use of antibiotic beads to salvage infected breast implants.

    Science.gov (United States)

    Sherif, Rami D; Ingargiola, Michael; Sanati-Mehrizy, Paymon; Torina, Philip J; Harmaty, Marco A

    2017-10-01

    When an implant becomes infected, implant salvage is often performed where the implant is removed, capsulectomy is performed, and a new implant is inserted. The patient is discharged with a PICC line and 6-8 weeks of intravenous (IV) antibiotics. This method has variable success and subjects the patient to long-term systemic antibiotics. In the 1960s, the use of antibiotic-impregnated beads for the treatment of chronic osteomyelitis was described. These beads deliver antibiotic directly to the site of the infection, thereby eliminating the complications of systemic IV antibiotics. This study aimed to present a case series illustrating the use of STIMULAN calcium sulfate beads loaded with vancomycin and tobramycin to increase the rate of salvage of the infected implant and forgo IV antibiotics. A retrospective analysis was performed of patients who were treated at Mount Sinai Hospital for implant infection with salvage and antibiotic beads. Twelve patients were identified, 10 of whom had breast cancer. Comorbidities included hypertension, smoking, and immunocompromised status. Infections were noted anywhere from 5 days to 8 years postoperatively. Salvage was successful in 9 out of the 12 infected implants using antibiotic bead therapy without home IV antibiotics. The use of antibiotic beads is promising for salvaging infected breast implants without IV antibiotics. Seventy-five percent of the implants were successfully salvaged. Of the three patients who had unsalvageable implants, one was infected with antibiotic-resistant Rhodococcus that was refractory to bead therapy and one was noncompliant with postoperative instructions. Copyright © 2017 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  17. Antimony sorption properties of chitosan - nano TiO2 composite beads

    International Nuclear Information System (INIS)

    Nishad, Padala Abdul; Bhaskarapillai, Anupkumar; Velmurugan, Sankaralingam

    2015-01-01

    Routine decontamination campaigns of nuclear reactors are generally effective in removing various radionuclides such as cobalt, caesium, etc., and bring down the radiation field. However, during some of the decontamination campaigns, the radiation field at some surfaces was seen to have actually gone up. This was found to be due to lack of removal of antimony isotopes by the regular ion exchange resins used, which subsequently deposited over out of core surfaces leading to increased radiation field on those surfaces. Thus there exists a need for efficient antimony removal system. We have synthesised nano titania impregnated - epichlorohydrin crosslinked chitosan beads, which were found to have high sorption capacity for antimony. The beads, which were synthesised in formats suitable for large scale (column mode) applications, were shown to be effective sorbent of antimony in both +3 and +5 oxidation states. The sorbent exhibited complete removal of antimony from its aqueous solutions of concentration ranging from 150 ppb to 120 ppm. In order to understand the sorption mechanism and to fine tune the bead composition, the effect of crosslinker concentration used during the synthesis on the swelling and sorption properties of the beads was investigated in detail. The variation effected significant changes in physical parameters such as bead diameter, swelling ratio, equilibrium water content and true wet density. Sorption capacity, unlike with regular resins, was found to increase with increase in crosslinker amount. The antimony sorption capacity of the crosslinked beads prepared by crosslinking 0.3 g uncrosslinked beads with 6.4 mmol epichlorohydrin (crosslinker) was 493 μmol/g. Non-crosslinked beads showed a capacity of 75 μmol/g, while the crosslinked beads made with the least amount of crosslinker (0.64 mmol per 0.3 g beads) showed a capacity of 133 μmol/g. These results indicate the possible involvement of the crosslinker in the sorption. (author)

  18. SparseBeads data: benchmarking sparsity-regularized computed tomography

    DEFF Research Database (Denmark)

    Jørgensen, Jakob Sauer; Coban, Sophia B.; Lionheart, William R. B.

    2017-01-01

    -regularized reconstruction. A collection of 48 x-ray CT datasets called SparseBeads was designed for benchmarking SR reconstruction algorithms. Beadpacks comprising glass beads of five different sizes as well as mixtures were scanned in a micro-CT scanner to provide structured datasets with variable image sparsity levels...

  19. A novel tubular linear motor equipped with radially anisotropic NdFeB ring magnets

    International Nuclear Information System (INIS)

    Hor, P.J.

    1998-01-01

    The paper describes the design synthesis and optimisation of a novel tubular linear motor employing radially magnetised anisotropic ring magnets. Design issues, related to optimising the dimensions for maximum acceleration capability, minimum cogging force and low harmonic distortion in the emf waveform, are discussed. The influence of inhomogeneities in the magnets on the performance of a prototype motor is discussed, and its dynamic performance is validated experimentally against a typical target specification for automated high-speed manufacturing applications. (orig.)

  20. Bead-based competitive fluorescence immunoassay for sensitive and rapid diagnosis of cyanotoxin risk in drinking water.

    Science.gov (United States)

    Yu, Hye-Weon; Jang, Am; Kim, Lan Hee; Kim, Sung-Jo; Kim, In S

    2011-09-15

    Due to the increased occurrence of cyanobacterial blooms and their toxins in drinking water sources, effective management based on a sensitive and rapid analytical method is in high demand for security of safe water sources and environmental human health. Here, a competitive fluorescence immunoassay of microcystin-LR (MCYST-LR) is developed in an attempt to improve the sensitivity, analysis time, and ease-of-manipulation of analysis. To serve this aim, a bead-based suspension assay was introduced based on two major sensing elements: an antibody-conjugated quantum dot (QD) detection probe and an antigen-immobilized magnetic bead (MB) competitor. The assay was composed of three steps: the competitive immunological reaction of QD detection probes against analytes and MB competitors, magnetic separation and washing, and the optical signal generation of QDs. The fluorescence intensity was found to be inversely proportional to the MCYST-LR concentration. Under optimized conditions, the proposed assay performed well for the identification and quantitative analysis of MCYST-LR (within 30 min in the range of 0.42-25 μg/L, with a limit of detection of 0.03 μg/L). It is thus expected that this enhanced assay can contribute both to the sensitive and rapid diagnosis of cyanotoxin risk in drinking water and effective management procedures.

  1. Microfluidic high gradient magnetic cell separation

    Science.gov (United States)

    Inglis, David W.; Riehn, Robert; Sturm, James C.; Austin, Robert H.

    2006-04-01

    Separation of blood cells by native susceptibility and by the selective attachment of magnetic beads has recently been demonstrated on microfluidic devices. We discuss the basic principles of how forces are generated via the magnetic susceptibility of an object and how microfluidics can be combined with micron-scale magnetic field gradients to greatly enhance in principle the fractionating power of magnetic fields. We discuss our efforts and those of others to build practical microfluidic devices for the magnetic separation of blood cells. We also discuss our attempts to integrate magnetic separation with other microfluidic features for developing handheld medical diagnostic tools.

  2. Design optimization of a linear permanent magnet synchronous motor for extra low force pulsations

    International Nuclear Information System (INIS)

    Isfahani, Aarsh Hassanpour; Vaez-Zadeh, Sadegh

    2007-01-01

    Air cored linear permanent magnet synchronous motors have essentially low force pulsations due to the lack of the primary iron core and teeth. However, a motor design with much lower force pulsations is required for many precise positioning systems, as in fabrication of microelectronic chips. This paper presents the design optimization of an air cored linear permanent magnet synchronous motor with extra low force pulsations for such applications. In order to achieve the goal, an analytical layer model of the machine is developed. A very effective objective function regarding force pulsations is then proposed; while the selected motor dimensions are regarded as the design variables. A genetic algorithm is used to find the optimal motor dimensions. This results in a substantial ninety percent reduction in the force pulsations. The design optimization is verified by a finite element method

  3. REVIEW: CHITOSAN BASED HYDROGEL POLYMERIC BEADS – AS DRUG DELIVERY SYSTEM

    Directory of Open Access Journals (Sweden)

    Manjusha Rani

    2010-11-01

    Full Text Available Chitosan obtained by alkaline deacetylation of chitin is a non-toxic, biocompatible, and biodegradable natural polymer. Chitosan-based hydrogel polymeric beads have been extensively studied as micro- or nano-particulate carriers in the pharmaceutical and medical fields, where they have shown promise for drug delivery as a result of their controlled and sustained release properties, as well as biocompatibility with tissue and cells. To introduce desired properties and enlarge the scope of the potential applications of chitosan, graft copolymerization with natural or synthetic polymers on it has been carried out, and also, various chitosan derivatives have been utilized to form beads. The desired kinetics, duration, and rate of drug release up to therapeutical level from polymeric beads are limited by specific conditions such as beads material and their composition, bead preparation method, amount of drug loading, drug solubility, and drug polymer interaction. The present review summarizes most of the available reports about compositional and structural effects of chitosan-based hydrogel polymeric beads on swelling, drug loading, and releasing properties. From the studies reviewed it is concluded that chitosan-based hydrogel polymeric beads are promising drug delivery systems.

  4. Design of systems for handling radioactive ion exchange resin beads

    International Nuclear Information System (INIS)

    Shapiro, S.A.; Story, G.L.

    1979-01-01

    The flow of slurries in pipes is a complex phenomenon. There are little slurry data available on which to base the design of systems for radioactive ion exchange resin beads and, as a result, the designs vary markedly in operating plants. With several plants on-line, the opportunity now exists to evaluate the designs of systems handling high activity spent resin beads. Results of testing at Robbins and Meyers Pump Division to quantify the behavior of resin bead slurries are presented. These tests evaluated the following slurry parameters; resin slurry velocity, pressure drop, bead degradation, and slurry concentration effects. A discussion of the general characteristics of resin bead slurries is presented along with a correlation to enable the designer to establish the proper flowrate for a given slurry composition and flow regime as a function of line size. Guidelines to follow in designing a resin handling system are presented

  5. Flow Cytometry-Based Bead-Binding Assay for Measuring Receptor Ligand Specificity

    NARCIS (Netherlands)

    Sprokholt, Joris K.; Hertoghs, Nina; Geijtenbeek, Teunis B. H.

    2016-01-01

    In this chapter we describe a fluorescent bead-binding assay, which is an efficient and feasible method to measure interaction between ligands and receptors on cells. In principle, any ligand can be coated on fluorescent beads either directly or via antibodies. Binding between ligand-coated beads

  6. 49 CFR 173.221 - Polymeric beads, expandable and Plastic molding compound.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Polymeric beads, expandable and Plastic molding... Than Class 1 and Class 7 § 173.221 Polymeric beads, expandable and Plastic molding compound. (a) Non-bulk shipments of Polymeric beads (or granules), expandable, evolving flammable vapor and Plastic...

  7. Development of bead-type radiophotoluminescence glass dosimeter applicable to various purposes

    International Nuclear Information System (INIS)

    Sato, F.; Toyota, Y.; Maki, D.; Zushi, N.; Kato, Y.; Yamamoto, T.; Iida, T.

    2013-01-01

    Bead-type radiophotoluminescence (RPL) glass dosimeters were well fabricated with a gas-particle jet flame system for glass melting-cooling process. A rod of silver-activated phosphate glass was pulverized into micrometer-size particles. Spherical glass particles were formed from the pulverized glass particles in the high-temperature jet flame owing to the surface tension of the glass material. Some groups of spherical glass particles were irradiated with X-rays and their RPL was demonstrably observed for their exposure to UV light. A flexible RPL glass sheet was also made of bead-type RPL glass dosimeters and was useful for radiation imaging. Bead-type RPL glass dosimeters are expected to be used for dose monitoring in highly radioactively-contaminated area. -- Highlights: ► We developed bead-type radiophotoluminescence glass dosimeters. ► Bead-type glass RPL dosimeters are satisfactorily used as radiation dosimeters. ► A flexible RPL glass sheet is made of bead-type RPL glass dosimeters

  8. Characterization of high flux magnetized helium plasma in SCU-PSI linear device

    Science.gov (United States)

    Xiaochun, MA; Xiaogang, CAO; Lei, HAN; Zhiyan, ZHANG; Jianjun, WEI; Fujun, GOU

    2018-02-01

    A high-flux linear plasma device in Sichuan University plasma-surface interaction (SCU-PSI) based on a cascaded arc source has been established to simulate the interactions between helium and hydrogen plasma with the plasma-facing components in fusion reactors. In this paper, the helium plasma has been characterized by a double-pin Langmuir probe. The results show that the stable helium plasma beam with a diameter of 26 mm was constrained very well at a magnetic field strength of 0.3 T. The core density and ion flux of helium plasma have a strong dependence on the applied current, magnetic field strength and gas flow rate. It could reach an electron density of 1.2 × 1019 m-3 and helium ion flux of 3.2 × 1022 m-2 s-1, with a gas flow rate of 4 standard liter per minute, magnetic field strength of 0.2 T and input power of 11 kW. With the addition of -80 V applied to the target to increase the helium ion energy and the exposure time of 2 h, the flat top temperature reached about 530 °C. The different sizes of nanostructured fuzz on irradiated tungsten and molybdenum samples surfaces under the bombardment of helium ions were observed by scanning electron microscopy. These results measured in the SCU-PSI linear device provide a reference for International Thermonuclear Experimental Reactor related PSI research.

  9. On the occurrence of ‘bead lightning’ phenomena in long laboratory sparks

    Energy Technology Data Exchange (ETDEWEB)

    Vayanganie, S.P.A., E-mail: amilavayanganie@gmail.com [Atmospheric Physics and Lightning Research Group, University of Colombo, Colombo 03 (Sri Lanka); Cooray, V.; Rahman, Mahbubur; Hettiarachchi, Pasan; Diaz, Oscar [Lightning Research Group, The Ångström Laboratory Division of Electricity, Department of Engineering Sciences, Uppsala University, Box 534, SE-751 21 Uppsala (Sweden); Fernando, M. [Atmospheric Physics and Lightning Research Group, University of Colombo, Colombo 03 (Sri Lanka)

    2016-02-22

    The formation of bead lightning, where the lightning channel appears to break up into luminous fragments, is still an object of speculation. Here we report similar observations in laboratory discharges. Analysis of time resolved photographs shows that the discharge channel exhibits a ‘bead pattern’ in the decaying stage of the discharge and the occurrence of loops in the channel sections where the bead pattern is observed. This result presents the first evidence that the rapid cooling of non-uniform channel sections could lead to the formation of beads. It is suggested that periodically occurring non-uniform channel sections could explain the bead pattern of lightning discharges. - Highlights: • For the first time, the occurrence of bead patterns in the channel of laboratory sparks was reported. • Depending on the geometry some regions of the channel decays faster than the other sections. • A possible mechanism for the occurrence of beads in decaying states of lightning flashes is proposed.

  10. Measuring binding of protein to gel-bound ligands using magnetic levitation.

    Science.gov (United States)

    Shapiro, Nathan D; Mirica, Katherine A; Soh, Siowling; Phillips, Scott T; Taran, Olga; Mace, Charles R; Shevkoplyas, Sergey S; Whitesides, George M

    2012-03-28

    This paper describes the use of magnetic levitation (MagLev) to measure the association of proteins and ligands. The method starts with diamagnetic gel beads that are functionalized covalently with small molecules (putative ligands). Binding of protein to the ligands within the bead causes a change in the density of the bead. When these beads are suspended in a paramagnetic aqueous buffer and placed between the poles of two NbFeB magnets with like poles facing, the changes in the density of the bead on binding of protein result in changes in the levitation height of the bead that can be used to quantify the amount of protein bound. This paper uses a reaction-diffusion model to examine the physical principles that determine the values of rate and equilibrium constants measured by this system, using the well-defined model system of carbonic anhydrase and aryl sulfonamides. By tuning the experimental protocol, the method is capable of quantifying either the concentration of protein in a solution, or the binding affinities of a protein to several resin-bound small molecules simultaneously. Since this method requires no electricity and only a single piece of inexpensive equipment, it may find use in situations where portability and low cost are important, such as in bioanalysis in resource-limited settings, point-of-care diagnosis, veterinary medicine, and plant pathology. It still has several practical disadvantages. Most notably, the method requires relatively long assay times and cannot be applied to large proteins (>70 kDa), including antibodies. The design and synthesis of beads with improved characteristics (e.g., larger pore size) has the potential to resolve these problems.

  11. Five degree-of-freedom control of an ultra-precision magnetically-suspended linear bearing. Ph.D. Thesis - MIT

    Science.gov (United States)

    Trumper, David L.; Slocum, A. H.

    1991-01-01

    The authors constructed a high precision linear bearing. A 10.7 kg platen measuring 125 mm by 125 mm by 350 mm is suspended and controlled in five degrees of freedom by seven electromagnets. The position of the platen is measured by five capacitive probes which have nanometer resolution. The suspension acts as a linear bearing, allowing linear travel of 50 mm in the sixth degree of freedom. In the laboratory, this bearing system has demonstrated position stability of 5 nm peak-to-peak. This is believed to be the highest position stability yet demonstrated in a magnetic suspension system. Performance at this level confirms that magnetic suspensions can address motion control requirements at the nanometer level. The experimental effort associated with this linear bearing system is described. Major topics are the development of models for the suspension, implementation of control algorithms, and measurement of the actual bearing performance. Suggestions for the future improvement of the bearing system are given.

  12. Study on a high thrust force bi-double-sided permanent magnet linear synchronous motor

    Directory of Open Access Journals (Sweden)

    Liang Tong

    2016-03-01

    Full Text Available A high thrust force bi-double-sided permanent magnet linear synchronous motor used in gantry-type five-axis machining center is designed and its performance was tested in this article. This motor is the subproject of Chinese National Science and Technology Major Project named as “development of domestic large thrust linear motor used in high-speed gantry-type five-axis machining center project” jointly participated by enterprises and universities. According to the requirement of the application environment and motor performance parameters, the linear motor’s basic dimensions, form of windings, and magnet arrangement are preliminarily specified through theoretical analysis and calculation. To verify the correctness of the result of the calculation, the finite element model of the motor is established. The static and dynamic characteristics of the motor are studied and analyzed through the finite element method, and the initial scheme is revised. The prototype of the motor is manufactured based on the final revised structure parameters, and the performance of the motor is fully tested using the evaluation platform for direct-drive motor component. Experimental test results meet the design requirements and show the effectiveness of design method and process.

  13. Development of polymer-extractant composite beads for separation of radionuclides

    International Nuclear Information System (INIS)

    Kumar, Manmohan; Singh, Krishankant; Bajaj, P.N.

    2009-01-01

    A novel micro porous polymer-extractant composite bead system, containing liquid extractant encapsulated in the core of a polymeric shell, with required porosity and hydrophilicity, to allow exchange of radionuclides without, any significant leaching out of the encapsulated extractant, has been developed for solid-liquid extraction of radionuclides from acidic waste solutions. The reuse of the beads is possible as there is practically no change in its radionuclide extraction efficiency, after repeated extraction second time. The high porosity and hydrophilicity of the synthesized TBP-encapsulated polymeric beads is evident from the presence of ∼ 78% water in the swollen condition. Evaluation of the synthesized beads for extraction of uranium and plutonium from aqueous acidic waste solutions, indicated possibility of their use under the conditions of PUREX process. The aliquate 336-encapsulated polymeric beads showed selective extraction of plutonium from aqueous nitrate solutions in the presence of uranium, and back extraction of the loaded plutonium, using dilute nitric acid or ascorbic acid. (author)

  14. Combining magnetic nanoparticle with biotinylated nanobodies for rapid and sensitive detection of influenza H3N2

    Science.gov (United States)

    Zhu, Min; Hu, Yonghong; Li, Guirong; Ou, Weijun; Mao, Panyong; Xin, Shaojie; Wan, Yakun

    2014-09-01

    Our objective is to develop a rapid and sensitive assay based on magnetic beads to detect the concentration of influenza H3N2. The possibility of using variable domain heavy-chain antibodies (nanobody) as diagnostic tools for influenza H3N2 was investigated. A healthy camel was immunized with inactivated influenza H3N2. A nanobody library of 8 × 108 clones was constructed and phage displayed. After three successive biopanning steps, H3N2-specific nanobodies were successfully isolated, expressed in Escherichia coli, and purified. Sequence analysis of the nanobodies revealed that we possessed four classes of nanobodies against H3N2. Two nanobodies were further used to prepare our rapid diagnostic kit. Biotinylated nanobody was effectively immobilized onto the surface of streptavidin magnetic beads. The modified magnetic beads with nanobody capture specifically influenza H3N2 and can still be recognized by nanobodies conjugated to horseradish peroxidase (HRP) conjugates. Under optimized conditions, the present immunoassay exhibited a relatively high sensitive detection with a limit of 50 ng/mL. In conclusion, by combining magnetic beads with specific nanobodies, this assay provides a promising influenza detection assay to develop a potential rapid, sensitive, and low-cost diagnostic tool to screen for influenza infections.

  15. Porous chitosan beads of superior mechanical properties for the covalent immobilization of enzymes.

    Science.gov (United States)

    Wahba, Marwa I

    2017-12-01

    Porous chitosan beads of superior mechanical properties were produced via a two stepped treatment process. First, the chitosan ionotropic gelation solution was supplemented with Na 2 CO 3 , which acted as a porogen. Afterwards, the beads were chemically cross-linked with glutaraldehyde. This treatment also caused the produced porous chitosan beads to acquire higher observed activities of immobilized β-d-galactosidase (β-gal). The observed activities of the β-gal immobilized onto the 0.2M and the 0.35M Na 2 CO 3 treated beads were 1.63 and 1.91 fold respectively, higher than the activity offered by the control beads. Nevertheless, both the control beads and the 0.2M Na 2 CO 3 beads caused the optimum pH range of β-gal to shift from 4.6-5.1 to ∼2.7-5. The enzyme's optimum temperature shifted from 55 to 60°C after its immobilization onto the control chitosan beads whereas the β-gal immobilized onto the 0.2M Na 2 CO 3 chitosan beads exhibited a temperature optimum of 55-60°C. The reusability study revealed the superiority of the 0.2M Na 2 CO 3 treated beads which retained 59.1% of their initial activity during the 13th enzymatic cycle. On the other hand, the control chitosan beads were fragmented and lost their activity after only four enzymatic cycles. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Linear field demagnetisation of artificial magnetic square ice

    Directory of Open Access Journals (Sweden)

    Jason Phillip Morgan

    2013-12-01

    Full Text Available We have studied experimentally the states formed in artificial square ice nanomagnet systems following demagnetisation in a rotating in-plane applied magnetic field that reduces to zero in a manner that is linear in time. The final states are found to be controlled via the system's lattice constant, which determines the strength of the magnetostatic interactions between the elements, as well as the field ramping rate. We understand these effects as a requirement that the system undergoes a sufficiently large number of active rotations within the critical field window in which elements may be reversed, such that the interactions are allowed to locally exert their influence if the ground state is to be approached. On the other hand, if quenched disorder is too strong when compared to the interaction strength, any close approach to the ground state is impossible. These results show that it is not necessary for there to be any ac component to the field amplitude that is applied to the system during demagnetisation, which is the method almost exclusively employed in field protocols reported to date. Furthermore, by optimising the parameters of our linear demagnetisation protocol, the largest field-generated ground state domains yet reported are found.

  17. Three-dimensional linear peeling-ballooning theory in magnetic fusion devices

    Energy Technology Data Exchange (ETDEWEB)

    Weyens, T., E-mail: tweyens@fis.uc3m.es; Sánchez, R.; García, L. [Departamento de Física, Universidad Carlos III de Madrid, Madrid 28911 (Spain); Loarte, A.; Huijsmans, G. [ITER Organization, Route de Vinon sur Verdon, 13067 Saint Paul Lez Durance (France)

    2014-04-15

    Ideal magnetohydrodynamics theory is extended to fully 3D magnetic configurations to investigate the linear stability of intermediate to high n peeling-ballooning modes, with n the toroidal mode number. These are thought to be important for the behavior of edge localized modes and for the limit of the size of the pedestal that governs the high confinement H-mode. The end point of the derivation is a set of coupled second order ordinary differential equations with appropriate boundary conditions that minimize the perturbed energy and that can be solved to find the growth rate of the perturbations. This theory allows of the evaluation of 3D effects on edge plasma stability in tokamaks such as those associated with the toroidal ripple due to the finite number of toroidal field coils, the application of external 3D fields for elm control, local modification of the magnetic field in the vicinity of ferromagnetic components such as the test blanket modules in ITER, etc.

  18. Magnet pole shape design for reduction of thrust ripple of slotless permanent magnet linear synchronous motor with arc-shaped magnets considering end-effect based on analytical method

    Directory of Open Access Journals (Sweden)

    Kyung-Hun Shin

    2017-05-01

    Full Text Available The shape of the magnet is essential to the performance of a slotless permanent magnet linear synchronous machine (PMLSM because it is directly related to desirable machine performance. This paper presents a reduction in the thrust ripple of a PMLSM through the use of arc-shaped magnets based on electromagnetic field theory. The magnetic field solutions were obtained by considering end effect using a magnetic vector potential and two-dimensional Cartesian coordinate system. The analytical solution of each subdomain (PM, air-gap, coil, and end region is derived, and the field solution is obtained by applying the boundary and interface conditions between the subdomains. In particular, an analytical method was derived for the instantaneous thrust and thrust ripple reduction of a PMLSM with arc-shaped magnets. In order to demonstrate the validity of the analytical results, the back electromotive force results of a finite element analysis and experiment on the manufactured prototype model were compared. The optimal point for thrust ripple minimization is suggested.

  19. Selection of the optimum magnet design for the International Linear Collider positron source helical undulator

    Directory of Open Access Journals (Sweden)

    D. J. Scott

    2007-03-01

    Full Text Available A comparison of possible undulator designs for the International Linear Collider positron source has resulted in a superconducting bifilar wire design being selected. After a comprehensive paper study and fabrication of the two preeminent designs, the superconducting undulator was chosen instead of the permanent magnet alternative. This was because of its superior performance in terms of magnetic field strength and quality, operational flexibility, risk of radiation damage, ease in achieving the required vacuum, and cost. The superconducting undulator design will now be developed into a complete system design for the full 200 m long magnet that is required.

  20. Modeling of welded bead profile for rapid prototyping by robotic MAG welding

    Institute of Scientific and Technical Information of China (English)

    CAO Yong; ZHU Sheng; WANG Tao; WANG Wanglong

    2009-01-01

    As a deposition technology, robotic metal active gas(MAG) welding has shown new promise for rapid prototyping (RP) of metallic parts. During the process of metal forming using robotic MAG welding, sectional profile of single-pass welded bead is critical to formed accuracy and quality of metal pans. In this paper, the experiments of single-pass welded bead for rapid prototyping using robotic MAG welding were carried out. The effect of some edge detectors on the cross-sectional edge of welded bead was discussed and curve fitting was applied using leat square fitting. Consequently, the mathematical model of welded bead profile was developed. The experimental results show that good shape could be obtained under suitable welding parameters. Canny operawr is suitable to edge detection of welded bead profile, and the mathematical model of welded bead profile developed is approximately parabola.

  1. pH-Dependent Behavior of Novel Gellan Beads Loaded with Naproxen.

    Science.gov (United States)

    Osmalek, Tomasz; Froelich, Anna; Milanowski, Bartlomiej; Bialas, Magdalena; Hyla, Kinga; Szybowicz, Miroslaw

    2018-01-01

    Oral administration of non-selective COX inhibitors involves the risk of serious side-effects. In the case of naproxen (NPX), the most frequent are those related to malfunctioning of the gastric mucosa. On the other hand, NPX and other NSAIDs are extensively studied in terms of colorectal cancer (CRC) prevention and inhibition, since it has been evidenced that COX-2 corresponds with the risk of the tumor occurrence and growth. Both side-effects in the stomach and possible antitumor activity of NPX justify the attempts to search for novel carriers for NPX with the site specific release in the colon. Thus, the aim of the work was to design, formulate and characterize low-acyl gellan gum (GG) macro beads as potential carriers for the delivery of NPX to the distal parts of the gastrointestinal tract. The beads were obtained by the ionotropic gelation technique. CaCl2 solution was used as a cross-linking medium. After production, the beads were dried and used for further experiments. First, pure NPX and the beads were evaluated by Raman spectroscopy and DSC studies. The surface and morphology of the beads were analyzed by SEM. Next, the drug encapsulation efficiency and content in the beads were determined. The swelling and degradation behavior of the beads were evaluated in four simulated gastrointestinal fluids at different pH (1.2; 4.5; 6.8 and 7.4). The NPX in vitro release studies were conducted on USP I apparatus (rotating basket) at pH=7.4 and compared to the commercial enteric tablet. The polymer content of 0.5 % was considered as too low to obtain spherical beads in the dried form. Raman spectra confirmed that NPX did not undergo structural changes during production process. DSC studies showed that thermal decomposition at lower temperatures was observed for formulations with the lowest amount of GG. It turned out that the most important factor which determined the morphology of the beads was the amount of gellan gum in the initial mixture. The beads revealed

  2. Magnetism of hexagonal close-packed nickel calculated by full-potential linearized augmented plane wave method

    International Nuclear Information System (INIS)

    Tian, F.; Tian, H.; Whitmore, L.; Ye, L.Y.

    2015-01-01

    The energy dependent on volume of hexagonal close-packed (hcp) nickel with different magnetism is calculated by full-potential linearized augmented plane wave method. Based on the calculation ferromagnetic state is found to be the most stable state. The magnetic moment of hcp Ni is calculated and compared to those calculated by different pseudo-potential methods. Furthermore, it is also compared to that of face-centered cubic (fcc) one with the reason discussed

  3. Handbook on linear motor application

    International Nuclear Information System (INIS)

    1988-10-01

    This book guides the application for Linear motor. It lists classification and speciality of Linear Motor, terms of linear-induction motor, principle of the Motor, types on one-side linear-induction motor, bilateral linear-induction motor, linear-DC Motor on basic of the motor, linear-DC Motor for moving-coil type, linear-DC motor for permanent-magnet moving type, linear-DC motor for electricity non-utility type, linear-pulse motor for variable motor, linear-pulse motor for permanent magneto type, linear-vibration actuator, linear-vibration actuator for moving-coil type, linear synchronous motor, linear electromagnetic motor, linear electromagnetic solenoid, technical organization and magnetic levitation and linear motor and sensor.

  4. Immuno-magnetic beads-based extraction-capillary zone electrophoresis-deep UV laser-induced fluorescence analysis of erythropoietin.

    Science.gov (United States)

    Wang, Heye; Dou, Peng; Lü, Chenchen; Liu, Zhen

    2012-07-13

    Erythropoietin (EPO) is an important glycoprotein hormone. Recombinant human EPO (rhEPO) is an important therapeutic drug and can be also used as doping reagent in sports. The analysis of EPO glycoforms in pharmaceutical and sports areas greatly challenges analytical scientists from several aspects, among which sensitive detection and effective and facile sample preparation are two essential issues. Herein, we investigated new possibilities for these two aspects. Deep UV laser-induced fluorescence detection (deep UV-LIF) was established to detect the intrinsic fluorescence of EPO while an immuno-magnetic beads-based extraction (IMBE) was developed to specifically extract EPO glycoforms. Combined with capillary zone electrophoresis (CZE), CZE-deep UV-LIF allows high resolution glycoform profiling with improved sensitivity. The detection sensitivity was improved by one order of magnitude as compared with UV absorbance detection. An additional advantage is that the original glycoform distribution can be completely preserved because no fluorescent labeling is needed. By combining IMBE with CZE-deep UV-LIF, the overall detection sensitivity was 1.5 × 10⁻⁸ mol/L, which was enhanced by two orders of magnitude relative to conventional CZE with UV absorbance detection. It is applicable to the analysis of pharmaceutical preparations of EPO, but the sensitivity is insufficient for the anti-doping analysis of EPO in blood and urine. IMBE can be straightforward and effective approach for sample preparation. However, antibodies with high specificity were the key for application to urine samples because some urinary proteins can severely interfere the immuno-extraction. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. High-force NdFeB-based magnetic tweezers device optimized for microrheology experiments.

    Science.gov (United States)

    Lin, Jun; Valentine, Megan T

    2012-05-01

    We present the design, calibration, and testing of a magnetic tweezers device that employs two pairs of permanent neodymium iron boron magnets surrounded by low-carbon steel focusing tips to apply large forces to soft materials for microrheology experiments. Our design enables the application of forces in the range of 1-1800 pN to ∼4.5 μm paramagnetic beads using magnet-bead separations in the range of 0.3-20 mm. This allows the use of standard coverslips and sample geometries. A high speed camera, custom LED-based illumination scheme, and mechanically stabilized measurement platform are employed to enable the measurement of materials with viscoelastic moduli as high as ∼1 kPa.

  6. High-force NdFeB-based magnetic tweezers device optimized for microrheology experiments

    Energy Technology Data Exchange (ETDEWEB)

    Lin Jun [Department of Mechanical Engineering, University of California, Santa Barbara, California 93106 (United States); Biomolecular Science and Engineering Program, University of California, Santa Barbara, California 93106 (United States); Valentine, Megan T. [Department of Mechanical Engineering, University of California, Santa Barbara, California 93106 (United States)

    2012-05-15

    We present the design, calibration, and testing of a magnetic tweezers device that employs two pairs of permanent neodymium iron boron magnets surrounded by low-carbon steel focusing tips to apply large forces to soft materials for microrheology experiments. Our design enables the application of forces in the range of 1-1800 pN to {approx}4.5 {mu}m paramagnetic beads using magnet-bead separations in the range of 0.3-20 mm. This allows the use of standard coverslips and sample geometries. A high speed camera, custom LED-based illumination scheme, and mechanically stabilized measurement platform are employed to enable the measurement of materials with viscoelastic moduli as high as {approx}1 kPa.

  7. Influence of recycled polystyrene beads on cement paste properties

    Directory of Open Access Journals (Sweden)

    Maaroufi Maroua

    2018-01-01

    Full Text Available In order to keep up with the requirements of sustainable development, there is a growing interest towards reducing the energy consumption in the construction and rehabilitation of buildings and the promotion of recycling waste in building materials. The use of recycled polystyrene beads in cement-based materials composition constitutes a solution to improve the insulation in buildings. This allows also limiting landfill by reusing the polystyrene waste. The aim of this study is to compare some properties and performances of a cement paste containing polystyrene beads to a reference paste designed with only the same cement. An experimental campaign was conducted and the obtained results showed that adding recycled polystyrene beads to a cement paste improves its hygro-thermal properties. Further studies are however necessary to better understand the real role of the polystyrene beads in the heat and mass transfers.

  8. Biological responses of human solid tumor cells to X-ray irradiation within a 1.5-Tesla magnetic field generated by a magnetic resonance imaging–linear accelerator

    NARCIS (Netherlands)

    Wang, Li; Hoogcarspel, Stan Jelle; Wen, Zhifei; van Vulpen, Marco; Molkentine, David P.; Kok, Jan; Lin, Steven H.; Broekhuizen, Roel; Ang, Kie Kian; Bovenschen, Niels; Raaymakers, Bas W.; Frank, Steven J.

    2016-01-01

    Devices that combine magnetic resonance imaging with linear accelerators (MRL) represent a novel tool for MR-guided radiotherapy. However, whether magnetic fields (MFs) generated by these devices affect the radiosensitivity of tumors is unknown. We investigated the influence of a 1.5-T MF on cell

  9. Developement of Spherical Polyurethane Beads

    Institute of Scientific and Technical Information of China (English)

    K. Maeda; H. Ohmori; H. Gyotoku

    2005-01-01

    @@ 1Results and Discussion We established a new method to produce the spherical polyurethane beads which have narrower distribution of particle size. This narrower distribution was achieved by the polyurethane prepolymer which contains ketimine as a blocked chain-extending agent. Firstly, the prepolymer is dispersed into the aqueous solution containing surfactant. Secondaly, water comes into the inside of prepolymer as oil phase. Thirdly, ketimine is hydrolyzed to amine, and amine reacts with prepolymer immediately to be polyurethane.Our spherical polyurethane beads are very suitable for automotive interior parts especially for instrument panel cover sheet producing under the slush molding method, because of good process ability, excellent durability to the sunlight and mechanical properties at low temperature. See Fig. 1 ,Fig. 2 and Fig. 3 (Page 820).

  10. Analysis of platinum content in biodegradable carboplatin-impregnated beads and retrospective assessment of tolerability for intralesional use of the beads in dogs following excision of subcutaneous sarcomas: 29 cases (2011-2014).

    Science.gov (United States)

    Hess, Theresa A; Drinkhouse, Macy E; Prey, Joshua D; Miller, Jonathan M; Fettig, Arthur A; Carberry, Carol A; Brenn, Stephen H; Bailey, Dennis B

    2018-02-15

    OBJECTIVE To evaluate platinum content in biodegradable carboplatin-impregnated beads and retrospectively assess tolerability and outcome data for dogs treated by intralesional placement of such beads following surgical excision of subcutaneous sarcomas. DESIGN Evaluation study and retrospective case series. SAMPLE 9 carboplatin-impregnated beads and 29 client-owned dogs. PROCEDURES Platinum content in 9 carboplatin-impregnated beads from 3 lots was measured by spectrophotometry, and calculated carboplatin content was compared with the labeled content. Medical records were searched to identify dogs with subcutaneous sarcomas for which treatment included placement of carboplatin-impregnated beads between 2011 and 2014. Signalment, tumor characteristics, surgical and histologic data, adverse events, and local recurrences were recorded. Associations between variables of interest and adverse events or local disease-free interval were analyzed. RESULTS In vitro analysis identified a mean ± SD platinum content of 5.38 ± 0.97 mg/bead. Calculated carboplatin content (10.24 ± 1.84 mg/bead) was significantly greater than the labeled amount (4.6 mg/bead). Bead weight and total platinum content differed significantly among lots, but platinum content per bead weight did not. Mild-to-moderate local adverse events were reported for 11 of 29 tumors; all resolved without additional surgery. No dogs had signs of systemic toxicosis. Overall local disease-free rates 1, 2, and 3 years after surgery were 70%, 70%, and 58%, respectively, as determined by Kaplan-Meier analysis. CONCLUSIONS AND CLINICAL RELEVANCE Carboplatin-impregnated beads were well tolerated; however, results of in vitro tests indicated that caution is needed because of manufacturing inconsistencies.

  11. A Superstrong Adjustable Permanent Magnet for the Final Focus Quadrupole in a Linear Collider

    International Nuclear Information System (INIS)

    Mihara, T.

    2004-01-01

    A super strong permanent magnet quadrupole (PMQ) was fabricated and tested. It has an integrated strength of 28.5T with overall length of 10 cm and a 7mm bore radius. The final focus quadrupole of a linear collider needs a variable focal length. This can be obtained by slicing the magnet into pieces along the beamline direction and rotating these slices. But this technique may lead to movement of the magnetic center and introduction of a skew quadrupole component when the strength is varied. A ''double ring structure'' can ease these effects. A second prototype PMQ, containing thermal compensation materials and with a double ring structure, has been fabricated. Worm gear is selected as the mechanical rotating scheme because the double ring structure needs a large torque to rotate magnets. The structure of the second prototype PMQ is shown

  12. Three-stage linear, split-Stirling cryocooler for 1 to 2K magnetic cold stage

    International Nuclear Information System (INIS)

    Longsworth, R.C.

    1993-08-01

    A long-life, linear, high efficiency 8K split Stirling cycle cryocooler was designed, built, and tested. The refrigerator is designed for cooling a 50 mW, 1.5K magnetic cold stage. Dual opposed piston compressors are driven by moving-coil linear motors. The three stage expander, although not completed, is also driven by a linear motor and is designed to produce 1 SW at 60K, 4W at 16K, and 1.2W at 8K. The cold regenerator employs a parallel gap construction for high efficiency. The key technology areas addressed include warm and cold flexible suspension bearings and a new cold regenerator geometry for high efficiency at 8K

  13. Porous silicon platform for optical detection of functionalized magnetic particles biosensing.

    Science.gov (United States)

    Ko, Pil Ju; Ishikawa, Ryousuke; Sohn, Honglae; Sandhu, Adarsh

    2013-04-01

    The physical properties of porous materials are being exploited for a wide range of applications including optical biosensors, waveguides, gas sensors, micro capacitors, and solar cells. Here, we review the fast, easy and inexpensive electrochemical anodization based fabrication porous silicon (PSi) for optical biosensing using functionalized magnetic particles. Combining magnetically labeled biomolecules with PSi offers a rapid and one-step immunoassay and real-time detection by magnetic manipulation of superparamagnetic beads (SPBs) functionalized with target molecules onto corresponding probe molecules immobilized inside nano-pores of PSi. We first give an introduction to electrochemical and chemical etching procedures used to fabricate a wide range of PSi structures. Next, we describe the basic properties of PSi and underlying optical scattering mechanisms that govern their unique optical properties. Finally, we give examples of our experiments that demonstrate the potential of combining PSi and magnetic beads for real-time point of care diagnostics.

  14. Surface imprinted beads for the recognition of human serum albumin.

    Science.gov (United States)

    Bonini, Francesca; Piletsky, Sergey; Turner, Anthony P F; Speghini, Adolfo; Bossi, Alessandra

    2007-04-15

    The synthesis of poly-aminophenylboronic acid (ABPA) imprinted beads for the recognition of the protein human serum albumin (HSA) is reported. In order to create homogeneous recognition sites, covalent immobilisation of the template HSA was exploited. The resulting imprinted beads were selective for HSA. The indirect imprinting factor (IF) calculated from supernatant was 1.6 and the direct IF, evaluated from the protein recovered from the beads, was 1.9. The binding capacity was 1.4 mg/g, which is comparable to commercially available affinity materials. The specificity of the HSA recognition was evaluated with competitive experiments, indicating a molar ratio 4.5/1 of competitor was necessary to displace half of the bound HSA. The recognition and binding of the imprinted beads was also tested with a complex sample, human serum and targeted removal of HSA without a loss of the other protein components was demonstrated. The easy preparation protocol of derivatised beads and a good protein recognition properties make the approach an attractive solution to analytical and bio-analytical problems in the field of biotechnology.

  15. Decolourisation of dyes under electro-Fenton process using Fe alginate gel beads

    International Nuclear Information System (INIS)

    Rosales, E.; Iglesias, O.; Pazos, M.; Sanromán, M.A.

    2012-01-01

    Highlights: ► Catalytic activity of Fe alginate gel beads for the remediation of wastewater was tested. ► New electro-Fenton process for the remediation of polluted wastewater. ► Continuous dye treatment without operational problem with high removal. - Abstract: This study focuses on the application of electro-Fenton technique by use of catalytic activity of Fe alginate gel beads for the remediation of wastewater contaminated with synthetic dyes. The Fe alginate gel beads were evaluated for decolourisation of two typical dyes, Lissamine Green B and Azure B under electro-Fenton process. After characterization of Fe alginate gel beads, the pH effect on the process with Fe alginate beads and a comparative study of the electro-Fenton process with free Fe and Fe alginate bead was done. The results showed that the use of Fe alginate beads increases the efficiency of the process; moreover the developed particles show a physical integrity in a wide range of pH (2–8). Around 98–100% of dye decolourisation was obtained for both dyes by electro-Fenton process in successive batches. Therefore, the process was performed with Fe alginate beads in a bubble continuous reactor. High color removal (87–98%) was attained for both dyes operating at a residence time of 30 min, without operational problems and maintaining particle shapes throughout the oxidation process. Consequently, the stable performance of Fe alginate beads opens promising perspectives for fast and economical treatment of wastewater polluted by dyes or similar organic contaminants.

  16. Decolourisation of dyes under electro-Fenton process using Fe alginate gel beads

    Energy Technology Data Exchange (ETDEWEB)

    Rosales, E.; Iglesias, O.; Pazos, M. [Department of Chemical Engineering, University of Vigo, Isaac Newton Building, Campus As Lagoas, Marcosende 36310, Vigo (Spain); Sanroman, M.A., E-mail: sanroman@uvigo.es [Department of Chemical Engineering, University of Vigo, Isaac Newton Building, Campus As Lagoas, Marcosende 36310, Vigo (Spain)

    2012-04-30

    Highlights: Black-Right-Pointing-Pointer Catalytic activity of Fe alginate gel beads for the remediation of wastewater was tested. Black-Right-Pointing-Pointer New electro-Fenton process for the remediation of polluted wastewater. Black-Right-Pointing-Pointer Continuous dye treatment without operational problem with high removal. - Abstract: This study focuses on the application of electro-Fenton technique by use of catalytic activity of Fe alginate gel beads for the remediation of wastewater contaminated with synthetic dyes. The Fe alginate gel beads were evaluated for decolourisation of two typical dyes, Lissamine Green B and Azure B under electro-Fenton process. After characterization of Fe alginate gel beads, the pH effect on the process with Fe alginate beads and a comparative study of the electro-Fenton process with free Fe and Fe alginate bead was done. The results showed that the use of Fe alginate beads increases the efficiency of the process; moreover the developed particles show a physical integrity in a wide range of pH (2-8). Around 98-100% of dye decolourisation was obtained for both dyes by electro-Fenton process in successive batches. Therefore, the process was performed with Fe alginate beads in a bubble continuous reactor. High color removal (87-98%) was attained for both dyes operating at a residence time of 30 min, without operational problems and maintaining particle shapes throughout the oxidation process. Consequently, the stable performance of Fe alginate beads opens promising perspectives for fast and economical treatment of wastewater polluted by dyes or similar organic contaminants.

  17. Comparison of four supports for adsorption of reactive dyes by immobilized Aspergillus fumigatus beads

    Institute of Scientific and Technical Information of China (English)

    WANG Bao-e; HU Yong-you

    2007-01-01

    Four materials, sodium carboxymethylcellulose (Na-CMC), sodium alginate (SA), polyvinyl alcohol (PVA), and chitosan (CTS), were prepared as supports for entrapping fungus Aspergillus fumigatus. The adsorption of synthetic dyes, reactive brilliant blue KN-R, and reactive brilliant red K-2BP, by these immobilized gel beads and plain gel beads was evaluated. The adsorption efficiencies of reactive brilliant red K-2BP and reactive brilliant blue KN-R by CTS immobilized beads were 89.1% and 93.5% in 12 h, respectively. The adsorption efficiency by Na-CMC immobilized beads was slightly lower than that of mycelial pellets. But the dye culture mediums were almost completely decolorized in 48 h using the above-mentioned two immobilized beads (exceeding 95%). The adsorption efficiency by SA immobilized beads exceeded 92% in 48 h. PVA-SA immobilized beads showed the lowest adsorption efficiency, which was 79.8% for reactive brilliant red K-2BP and 92.5% for reactive brilliant blue KN-R in 48 h. Comparing the adsorption efficiency by plain gel beads, Na-CMC plain gel beads ranked next to CTS ones. SA and PVA-SA plain gel beads hardly had the ability of adsorbing dyes. Subsequently, the growth of mycelia in Na-CMC and SA immobilized beads were evaluated. The biomass increased continuously in 72 h. The adsorption capacity of reactive brilliant red K-2BP and reactive brilliant blue KN-R by Na-CMC immobilized beads was 78.0 and 86.7 mg/g, respectively. The SEM micrographs show that the surface structure of Na-CMC immobilized bead is loose and finely porous, which facilitates diffusion of the dyes.

  18. Transition metal modified bulk BiFeO{sub 3} with improved magnetization and linear magneto-electric coupling

    Energy Technology Data Exchange (ETDEWEB)

    Puli, Venkata Sreenivas, E-mail: pvsri123@gmail.com [Department of Physics and Institute for Functional Nanomaterials, University of Puerto Rico, San Juan, PR 00936 (Puerto Rico); Kumar, A.; Panwar, N.; Panwar, I.C.; Katiyar, R.S. [Department of Physics and Institute for Functional Nanomaterials, University of Puerto Rico, San Juan, PR 00936 (Puerto Rico)

    2011-08-11

    Highlights: > Present composition (Bi{sub 0.9}Sm{sub 0.10}Fe{sub 0.95}Co{sub 0.05}O{sub 3} (BSFCO) have shown very high magnetization compared to parent BFO. > The magnetic hysteresis loops are well saturated with high saturation magnetization 2.89 emu/gm (unpoled and unleached) and 2.18 emu/gm (poled and unleached) respectively. > Converse ME coupling were found 0.8e-10 s m{sup -1} (H||E) and 0.6-0.8 x 10{sup -10} s m{sup -1} (H-perpendicular E) which are better than the single phase multiferroic obeying linear ME coupling. - Abstract: At present BiFeO{sub 3} (BFO) is the most attractive and sole example, which possesses low magnetization value, high leakage current and low polarization in ceramic form. Single-phase room temperature multiferroics are rare in nature. This paper deals with the improved magnetic and observed linear magneto-electric coupling in Co and Sm co-doped BiFeO{sub 3} ceramics synthesized by sol-gel process at low temperature {approx}600 deg. C. As synthesized Bi{sub 0.9}Sm{sub 0.10}Fe{sub 0.95}Co{sub 0.05}O{sub 3} (BSFCO) showed high impurities phases (20%) over wide range of calcination temperatures. Impurity phases reduced drastically from 20% to 5% after leaching with nitric acid. However the electrical and the magnetic properties were almost the same for both phases. Well-defined magnetic hysteresis with high magnetic moment was found at room temperature. Ferroelectric polarization studies demonstrated similar values and shape as reported in literature for the pure bulk BFO. Linear magneto-electric (ME) coupling and weak ME coefficient ({alpha}) {approx} 0.6 e-10 s m{sup -1} were observed in the co-doped BFO. The origin of the strong ferromagnetic property in our samples may be due to the presence of rare earth and transition metal ions at the lattice sites of BFO or due to impurity phase, since we have not seen any change in magnetization with reduction of impurity phase the later effect is more unlikely.

  19. Boiling phenomenon and heat transfer in bead-packed porous structure

    International Nuclear Information System (INIS)

    Zhang Xiaojie; ZHu Yanlei; Bai Bofeng; Yan Xiao; Xiao Zejun

    2009-01-01

    A visual study on pool boiling behavior and phase distribution was conducted on the porous structures made of staggered glass beads at atmospheric pressure. The bead-packed structure was heated on the bottom. The investigations were carried out respectively at different glass bead diameters which were 4 mm, 6 mm and 8 mm. The results show that during subcooled boiling, small isolated bubbles are formed on the heated surface and combine into main-bubbles, the dispersion frequency of the main-bubbles is low and the small bubbles scatter in the bead-packed porous structures. At the initial stage of saturated boiling, the bubble growth rate, the volume of main-bubbles and the range of continuous vapor phase increase. The dispersion frequency of main-bubbles increases with the increasing of heat flux. During film boiling, the heated surface is absolutely covered with vapor film and the porous structure is full of liquid. The larger the diameter of beads is, the higher heat flux is needed for the same phenomenon, and the higher maximum value of heat transfer coefficient will be. During the whole saturated boiling, and the heat transfer enhanced firstly and then weakened. Being opposite to that of the diameters of 4 mm and 8 mm, the heat transfer coefficient in the 6 mm-bead-packed porous structure decreases with the increasing of the heat flux. (authors)

  20. Non-linear Model Predictive Control for cooling strings of superconducting magnets using superfluid helium

    CERN Document Server

    AUTHOR|(SzGeCERN)673023; Blanco Viñuela, Enrique

    In each of eight arcs of the 27 km circumference Large Hadron Collider (LHC), 2.5 km long strings of super-conducting magnets are cooled with superfluid Helium II at 1.9 K. The temperature stabilisation is a challenging control problem due to complex non-linear dynamics of the magnets temperature and presence of multiple operational constraints. Strong nonlinearities and variable dead-times of the dynamics originate at strongly heat-flux dependent effective heat conductivity of superfluid that varies three orders of magnitude over the range of possible operational conditions. In order to improve the temperature stabilisation, a proof of concept on-line economic output-feedback Non-linear Model Predictive Controller (NMPC) is presented in this thesis. The controller is based on a novel complex first-principles distributed parameters numerical model of the temperature dynamics over a 214 m long sub-sector of the LHC that is characterized by very low computational cost of simulation needed in real-time optimizat...