WorldWideScience

Sample records for line scanning device

  1. Printing line/space patterns on nonplanar substrates using a digital micromirror device-based point-array scanning technique

    Kuo, Hung-Fei; Kao, Guan-Hsuan; Zhu, Liang-Xiu; Hung, Kuo-Shu; Lin, Yu-Hsin

    2018-02-01

    This study used a digital micromirror device (DMD) to produce point-array patterns and employed a self-developed optical system to define line-and-space patterns on nonplanar substrates. First, field tracing was employed to analyze the aerial images of the lithographic system, which comprised an optical system and the DMD. Multiobjective particle swarm optimization was then applied to determine the spot overlapping rate used. The objective functions were set to minimize linewidth and maximize image log slope, through which the dose of the exposure agent could be effectively controlled and the quality of the nonplanar lithography could be enhanced. Laser beams with 405-nm wavelength were employed as the light source. Silicon substrates coated with photoresist were placed on a nonplanar translation stage. The DMD was used to produce lithographic patterns, during which the parameters were analyzed and optimized. The optimal delay time-sequence combinations were used to scan images of the patterns. Finally, an exposure linewidth of less than 10 μm was successfully achieved using the nonplanar lithographic process.

  2. Scanning device for a spectrometer

    Ignat'ev, V.M.

    1982-01-01

    The invention belongs to scanning devices and is intended for spectrum scanning in spectral devices. The purpose of the invention is broadening of spectral scanning range. The device construction ensures the spectrum scanning range determined from revolution fractions to several revolutions of the monochromator drum head, any number of the drum head revolutions determined by integral number with addition of the drum revolution fractions with high degree of accuracy being possible

  3. Scanning device for scintigraphy

    Casale, R.

    1975-01-01

    A device is described for the scintigraphic scanning according to a horizontal plane, comprising: (a) A support provided with two guides horizontally and longitudinally located, one of which is located in the upper part of the support, while the second guide is located in the lower part of the support; (b) A carriage, movable with respect to the support along the two guides, provided in its upper part, projecting above the support, with rolling means suitable to support and to cause to slide along its axis a support rod for the first detector, horizontally and transversely located, said carriage being further provided in its lower part with a recess with possible rolling means suitable to support and to cause to slide along its axis a second support rod for the second detector, said second rod being located parallel to the first rod and below it; (c) One or two support rods for the detectors, the first of said rods being supported above the support in a sliding way along its axis, by the rolling means located in the upper part of the carriage, and the second rod if present is supported slidingly along its axis by the possible rolling means contained in the suitable recess which is provided in the lower part of the carriage, and (d) A vertical shaft supported by said carriage on which is mounted a toothed wheel for each rod, each toothed wheel engaging a positive drive belt or the like, which is connected to each said rod so that rotation of the shaft determines the simultaneous displacement of the two rods along their axes; and single motor means for driving said shaft during a scanning operation. (U.S.)

  4. Rapid line scan MR angiography

    Frahm, J.; Merboldt, K.D.; Hanicke, W.; Bruhn, H.

    1987-01-01

    Direct MR angiography may be performed using line scan imaging techniques combined with presaturation of stationary spins. Thus, a single line scan echo yields a projection of vessels due to the signal from reflowing unsaturated spins. Reconstruction of an angiographic image is performed line by line at slightly incremented positions. In particular, line scan angiography is direct and fast without a sensitivity to artifacts even for high flow rates. Image resolution and field of view may be chosen without restrictions, and zoom images using enhanced gradients may be recorded without aliasing artifacts. The method is robust with respect to eddy currents and pulsatile flow. Line scan MR angiograms of phantoms, animals, and human volunteers have been recorded using 90 0 radio frequency pulses and gradient-recalled echoes

  5. NEW SCANNING DEVICE FOR SCANNING TUNNELING MICROSCOPE APPLICATIONS

    SAWATZKY, GA; Koops, Karl Richard

    A small, single piezo XYZ translator has been developed. The device has been used as a scanner for a scanning tunneling microscope and has been tested successfully in air and in UHV. Its simple design results in a rigid and compact scanning unit which permits high scanning rates.

  6. Mjollnir Rotational Line Scan Diagnostics.

    1981-05-19

    using long cavity. M8 Removable Pellicle Beam Splitter for He-Ne Lineup Beam. Removed before HF or DF laser is turned on. 27 A 27 * A r of the chopper...three probe laser lines, however three lines were sequentially measured to verify the diagnostic equipment. Two of the three lines have been monitored

  7. An image scanning device using radiating energy

    Jacob, Daniel.

    1976-01-01

    Said invention relates to an image scanning device using radiating energy. More particularly, it relates to a device for generating a scanning beam of rectangular cross section from a γ or X-ray source. Said invention can be applied to radiographic units of the 'microdose' type used by airline staffs and others for the fast efficient inspection of luggage and parcels in view of detecting hidden things [fr

  8. Exabyte helical scan devices at Fermilab

    Constanta-Fanourakis, P.; Kaczar, K.; Oleynik, G.; Petravick, D.; Votava, M.; White, V.; Hockney, G.; Bracker, S.; de Miranda, J.M.

    1989-05-01

    Exabyte 8mm helical scan storage devices are in use at Fermilab in a number of applications. These devices have the functionality of magnetic tape, but use media which is much more economical and much more dense than conventional 9 track tape. 6 refs., 3 figs

  9. High resolution RGB color line scan camera

    Lynch, Theodore E.; Huettig, Fred

    1998-04-01

    A color line scan camera family which is available with either 6000, 8000 or 10000 pixels/color channel, utilizes off-the-shelf lenses, interfaces with currently available frame grabbers, includes on-board pixel by pixel offset correction, and is configurable and controllable via RS232 serial port for computer controlled or stand alone operation is described in this paper. This line scan camera is based on an available 8000 element monochrome line scan camera designed by AOA for OEM use. The new color version includes improvements such as better packaging and additional user features which make the camera easier to use. The heart of the camera is a tri-linear CCD sensor with on-chip color balancing for maximum accuracy and pinned photodiodes for low lag response. Each color channel is digitized to 12 bits and all three channels are multiplexed together so that the resulting camera output video is either a 12 or 8 bit data stream at a rate of up to 24Megpixels/sec. Conversion from 12 to 8 bit, or user-defined gamma, is accomplished by on board user-defined video look up tables. The camera has two user-selectable operating modes; lows speed, high sensitivity mode or high speed, reduced sensitivity mode. The intended uses of the camera include industrial inspection, digital archiving, document scanning, and graphic arts applications.

  10. X-ray Compton line scan tomography

    Kupsch, Andreas; Lange, Axel; Jaenisch, Gerd-Ruediger [Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin (Germany). Fachgruppe 8.5 - Mikro-ZfP; Hentschel, Manfred P. [Technische Univ. Berlin (Germany); Kardjilov, Nikolay; Markoetter, Henning; Hilger, Andre; Manke, Ingo [Helmholtz-Zentrum Berlin (HZB) (Germany); Toetzke, Christian [Potsdam Univ. (Germany)

    2015-07-01

    The potentials of incoherent X-ray scattering (Compton) computed tomography (CT) are investigated. The imaging of materials of very different atomic number or density at once is generally a perpetual challenge for X-ray tomography or radiography. In a basic laboratory set-up for simultaneous perpendicular Compton scattering and direct beam attenuation tomography are conducted by single channel photon counting line scans. This results in asymmetric distortions of the projection profiles of the scattering CT data set. In a first approach, corrections of Compton scattering data by taking advantage of rotational symmetry yield tomograms without major geometric artefacts. A cylindrical sample composed of PE, PA, PVC, glass and wood demonstrates similar Compton contrast for all the substances, while the conventional absorption tomogram only reveals the two high order materials. Comparison to neutron tomography reveals astonishing similarities except for the glass component (without hydrogen). Therefore, Compton CT offers the potential to replace neutron tomography, which requires much more efforts.

  11. Line-scan inspection of conifer seedlings

    Rigney, Michael P.; Kranzler, Glenn A.

    1993-05-01

    Almost two billion conifer seedlings are produced in the U.S. each year to support reforestation efforts. Seedlings are graded manually to improve viability after transplanting. Manual grading is labor-intensive and subject to human variability. Our previous research demonstrated the feasibility of automated tree seedling inspection with machine vision. Here we describe a system based on line-scan imaging, providing a three-fold increase in resolution and inspection rate. A key aspect of the system is automatic recognition of the seedling root collar. Root collar diameter, shoot height, and projected shoot and root areas are measured. Sturdiness ratio and shoot/root ratio are computed. Grade is determined by comparing measured features with pre-defined set points. Seedlings are automatically sorted. The precision of machine vision and manual measurements was determined in tests at a commercial forest nursery. Manual measurements of stem diameter, shoot height, and sturdiness ratio had standard deviations three times those of machine vision measurements. Projected shoot area was highly correlated (r2 equals 0.90) with shoot volume. Projected root area had good correlation (r2 equals 0.80) with root volume. Seedlings were inspected at rates as high as ten per second.

  12. Lansce Wire Scanning Diagnostics Device Mechanical Design

    Rodriguez Esparza, Sergio; Batygin, Yuri K.; Gilpatrick, John D.; Gruchalla, Michael E.; Maestas, Alfred J.; Pillai, Chandra; Raybun, Joseph L.; Sattler, F.D.; Sedillo, James Daniel; Smith, Brian G.

    2011-01-01

    The Accelerator Operations and Technology Division at Los Alamos National Laboratory operates a linear particle accelerator which utilizes 110 wire scanning diagnostics devices to gain position and intensity information of the proton beam. In the upcoming LANSCE improvements, 51 of these wire scanners are to be replaced with a new design, up-to-date technology and off-the-shelf components. This document outlines the requirements for the mechanical design of the LANSCE wire scanner and presents the recently developed linac wire scanner prototype. Additionally, this document presents the design modifications that have been implemented into the fabrication and assembly of this first linac wire scanner prototype. Also, this document will present the design for the second, third, and fourth wire scanner prototypes being developed. Prototypes 2 and 3 belong to a different section of the particle accelerator and therefore have slightly different design specifications. Prototype 4 is a modification of a previously used wire scanner in our facility. Lastly, the paper concludes with a plan for future work on the wire scanner development.

  13. Lansce Wire Scanning Diagnostics Device Mechanical Design

    Rodriguez Esparza, Sergio [Los Alamos National Laboratory; Batygin, Yuri K. [Los Alamos National Laboratory; Gilpatrick, John D. [Los Alamos National Laboratory; Gruchalla, Michael E. [Los Alamos National Laboratory; Maestas, Alfred J. [Los Alamos National Laboratory; Pillai, Chandra [Los Alamos National Laboratory; Raybun, Joseph L. [Los Alamos National Laboratory; Sattler, F. D. [Los Alamos National Laboratory; Sedillo, James Daniel [Los Alamos National Laboratory; Smith, Brian G. [Los Alamos National Laboratory

    2011-01-01

    The Accelerator Operations & Technology Division at Los Alamos National Laboratory operates a linear particle accelerator which utilizes 110 wire scanning diagnostics devices to gain position and intensity information of the proton beam. In the upcoming LANSCE improvements, 51 of these wire scanners are to be replaced with a new design, up-to-date technology and off-the-shelf components. This document outlines the requirements for the mechanical design of the LANSCE wire scanner and presents the recently developed linac wire scanner prototype. Additionally, this document presents the design modifications that have been implemented into the fabrication and assembly of this first linac wire scanner prototype. Also, this document will present the design for the second, third, and fourth wire scanner prototypes being developed. Prototypes 2 and 3 belong to a different section of the particle accelerator and therefore have slightly different design specifications. Prototype 4 is a modification of a previously used wire scanner in our facility. Lastly, the paper concludes with a plan for future work on the wire scanner development.

  14. Cooling system for baby EBM scanning device

    Abd Halim Baijan; Muhammad Zahidee Taat; Abu Bakar Ghazali; Mohd Rizal Md Chulan; Rokiah Mohd Sabri; Leo Kwee Wah; Mohd Rizal Ibrahim; Lojius Lombigit; Azaman Ahmad

    2009-01-01

    Heat exchange of the scanning window of baby EBM is a critical factor for maintaining the integrity of the window material structure. As the titanium foil which was used as the scanning window, the maximum temperature accepted for the foil should be 200 degree C. This paper will discuss a simple method of Bernoulli principle to obtain the correct air blower capacity in order to reduce the heat of the scanning window of Baby EBM. It was found that the required air pressure and air speed of the blower are 2613.6 Pascal and 237.6 m3/h respectively for the electron accelerator of 0.14 MeV energy and 10 mA beam current. (Author)

  15. Categorisation of full waveform data provided by laser scanning devices

    Ullrich, Andreas; Pfennigbauer, Martin

    2011-11-01

    In 2004, a laser scanner device for commercial airborne laser scanning applications, the RIEGL LMS-Q560, was introduced to the market, making use of a radical alternative approach to the traditional analogue signal detection and processing schemes found in LIDAR instruments so far: digitizing the echo signals received by the instrument for every laser pulse and analysing these echo signals off-line in a so-called full waveform analysis in order to retrieve almost all information contained in the echo signal using transparent algorithms adaptable to specific applications. In the field of laser scanning the somewhat unspecific term "full waveform data" has since been established. We attempt a categorisation of the different types of the full waveform data found in the market. We discuss the challenges in echo digitization and waveform analysis from an instrument designer's point of view and we will address the benefits to be gained by using this technique, especially with respect to the so-called multi-target capability of pulsed time-of-flight LIDAR instruments.

  16. LANSCE wire scanning diagnostics device mechanical design

    Rodriguez Esparza, Sergio

    2010-01-01

    The Los Alamos Neutron Science Center (LANSCE) is one of the major experimental science facilities at the Los Alamos National Laboratory (LANL). The core of LANSCE's work lies in the operation of a powerful linear accelerator, which accelerates protons up to 84% the speed oflight. These protons are used for a variety of purposes, including materials testing, weapons research and isotopes production. To assist in guiding the proton beam, a series of over one hundred wire scanners are used to measure the beam profile at various locations along the half-mile length of the particle accelerator. A wire scanner is an electro-mechanical device that moves a set of wires through a particle beam and measures the secondary emissions from the resulting beam-wire interaction to obtain beam intensity information. When supplemented with data from a position sensor, this information is used to determine the cross-sectional profile of the beam. This measurement allows beam operators to adjust parameters such as acceleration, beam steering, and focus to ensure that the beam reaches its destination as effectively as possible. Some of the current wire scanners are nearly forty years old and are becoming obsolete. The problem with current wire scanners comes in the difficulty of maintenance and reliability. The designs of these wire scanners vary making it difficult to keep spare parts that would work on all designs. Also many of the components are custom built or out-dated technology and are no longer in production.

  17. LANSCE wire scanning diagnostics device mechanical design

    Rodriguez Esparza, Sergio [Los Alamos National Laboratory

    2010-01-01

    The Los Alamos Neutron Science Center (LANSCE) is one of the major experimental science facilities at the Los Alamos National Laboratory (LANL). The core of LANSCE's work lies in the operation of a powerful linear accelerator, which accelerates protons up to 84% the speed oflight. These protons are used for a variety of purposes, including materials testing, weapons research and isotopes production. To assist in guiding the proton beam, a series of over one hundred wire scanners are used to measure the beam profile at various locations along the half-mile length of the particle accelerator. A wire scanner is an electro-mechanical device that moves a set of wires through a particle beam and measures the secondary emissions from the resulting beam-wire interaction to obtain beam intensity information. When supplemented with data from a position sensor, this information is used to determine the cross-sectional profile of the beam. This measurement allows beam operators to adjust parameters such as acceleration, beam steering, and focus to ensure that the beam reaches its destination as effectively as possible. Some of the current wire scanners are nearly forty years old and are becoming obsolete. The problem with current wire scanners comes in the difficulty of maintenance and reliability. The designs of these wire scanners vary making it difficult to keep spare parts that would work on all designs. Also many of the components are custom built or out-dated technology and are no longer in production.

  18. Line-scanning tomographic optical microscope with isotropic transfer function

    Gajdátsy, Gábor; Dudás, László; Erdélyi, Miklós; Szabó, Gábor

    2010-01-01

    An imaging method and optical system, referred to as a line-scanning tomographic optical microscope (LSTOM) using a combination of line-scanning technique and CT reconstruction principle, is proposed and studied theoretically and experimentally. In our implementation a narrow focus line is scanned over the sample and the reflected light is measured in a confocal arrangement. One such scan is equivalent to a transverse projection in tomography. Repeating the scanning procedure in several directions, a number of transverse projections are recorded from which the image can be obtained using conventional CT reconstruction algorithms. The resolution of the image is independent of the spatial dimensions and structure of the applied detector; furthermore, the transfer function of the system is isotropic. The imaging performance of the implemented confocal LSTOM was compared with a point-scanning confocal microscope, based on recorded images. These images demonstrate that the resolution of the confocal LSTOM exceeds (by 15%) the resolution limit of a point-scanning confocal microscope

  19. AUTOMATIC RAILWAY POWER LINE EXTRACTION USING MOBILE LASER SCANNING DATA

    S. Zhang

    2016-06-01

    Full Text Available Research on power line extraction technology using mobile laser point clouds has important practical significance on railway power lines patrol work. In this paper, we presents a new method for automatic extracting railway power line from MLS (Mobile Laser Scanning data. Firstly, according to the spatial structure characteristics of power-line and trajectory, the significant data is segmented piecewise. Then, use the self-adaptive space region growing method to extract power lines parallel with rails. Finally use PCA (Principal Components Analysis combine with information entropy theory method to judge a section of the power line whether is junction or not and which type of junction it belongs to. The least squares fitting algorithm is introduced to model the power line. An evaluation of the proposed method over a complicated railway point clouds acquired by a RIEGL VMX450 MLS system shows that the proposed method is promising.

  20. Device for the track useful signal discrimination during the image scanning form bubble chambers

    Osipov, E.A.; Uvarov, V.A.

    1976-01-01

    A device for the image processing from the bubble chambers, developed to increase the reliability of the track useful signal discrimination at the image scanning from the background component is described. The device consists of a low-pass filter, repetition and memory circuit and subtraction circuit. Besides a delay line and extra channel consisting of a differentiating circuit in series with the selective shaping circuit are introduced into the device. The output signal of the selective shaping is the controlling signal of the repetition and memory circuit, at the output of which a signal corresponding the background component is formed. The functional diagram of the device operation is presented

  1. PEPR and other CRT scanning and measuring devices

    Pless, Irwin A. (Massachusetts Institute of Technology, Cambridge, MA 02139 (United States))

    1994-07-01

    This talk concentrates on the brief history of the PEPR (Precision Encoding and Pattern Recognition) scanning and measuring device.I restrict this reminiscence to just a short history of PEPR, the other various CRT scanners, a short summary of the capabilities of this scanner and some fond memories. ((orig.))

  2. PEPR and other CRT scanning and measuring devices

    Pless, Irwin A.

    1994-01-01

    This talk concentrates on the brief history of the PEPR (Precision Encoding and Pattern Recognition) scanning and measuring device.I restrict this reminiscence to just a short history of PEPR, the other various CRT scanners, a short summary of the capabilities of this scanner and some fond memories. ((orig.))

  3. Transmission environmental scanning electron microscope with scintillation gaseous detection device

    Danilatos, Gerasimos; Kollia, Mary; Dracopoulos, Vassileios

    2015-01-01

    A transmission environmental scanning electron microscope with use of a scintillation gaseous detection device has been implemented. This corresponds to a transmission scanning electron microscope but with addition of a gaseous environment acting both as environmental and detection medium. A commercial type of low vacuum machine has been employed together with appropriate modifications to the detection configuration. This involves controlled screening of various emitted signals in conjunction with a scintillation gaseous detection device already provided with the machine for regular surface imaging. Dark field and bright field imaging has been obtained along with other detection conditions. With a progressive series of modifications and tests, the theory and practice of a novel type of microscopy is briefly shown now ushering further significant improvements and developments in electron microscopy as a whole. - Highlights: • Novel scanning transmission electron microscopy (STEM) with an environmental scanning electron microscope (ESEM) called TESEM. • Use of the gaseous detection device (GDD) in scintillation mode that allows high resolution bright and dark field imaging in the TESEM. • Novel approach towards a unification of both vacuum and environmental conditions in both bulk/surface and transmission mode of electron microscopy

  4. Transmission environmental scanning electron microscope with scintillation gaseous detection device.

    Danilatos, Gerasimos; Kollia, Mary; Dracopoulos, Vassileios

    2015-03-01

    A transmission environmental scanning electron microscope with use of a scintillation gaseous detection device has been implemented. This corresponds to a transmission scanning electron microscope but with addition of a gaseous environment acting both as environmental and detection medium. A commercial type of low vacuum machine has been employed together with appropriate modifications to the detection configuration. This involves controlled screening of various emitted signals in conjunction with a scintillation gaseous detection device already provided with the machine for regular surface imaging. Dark field and bright field imaging has been obtained along with other detection conditions. With a progressive series of modifications and tests, the theory and practice of a novel type of microscopy is briefly shown now ushering further significant improvements and developments in electron microscopy as a whole. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Software of the control computer of HPD scanning device

    Belyaev, A.V.; Rubtsov, V.F.; Slepnev, S.K.; Susov, Yu.I.

    1979-01-01

    Specific features of HPD measuring system are considered which are important for TPA-1001i computer programming, being the control computer of scanning device. The instruction language intended for interacting the computer with HPD electronics is given. Resident, auxiliary and test subprograms including those for interrupt handling, for monitoring, a driver for the operation with a teletype, a loader, a cross-assembler are described

  6. Spiral scan long object reconstruction through PI line reconstruction

    Tam, K C; Hu, J; Sourbelle, K

    2004-01-01

    The response of a point object in a cone beam (CB) spiral scan is analysed. Based on the result, a reconstruction algorithm for long object imaging in spiral scan cone beam CT is developed. A region-of-interest (ROI) of the long object is scanned with a detector smaller than the ROI, and a portion of it can be reconstructed without contamination from overlaying materials. The top and bottom surfaces of the ROI are defined by two sets of PI lines near the two ends of the spiral path. With this novel definition of the top and bottom ROI surfaces and through the use of projective geometry, it is straightforward to partition the cone beam image into regions corresponding to projections of the ROI, the overlaying objects or both. This also simplifies computation at source positions near the spiral ends, and makes it possible to reduce radiation exposure near the spiral ends substantially through simple hardware collimation. Simulation results to validate the algorithm are presented

  7. Improved rectilinear scanning device for the whole body

    Berninger, W.H.

    1975-01-01

    A rectilinear scanning device for whole-body counting is described in which the spacial resolution is considerably improved upon by using photomultipliers with spherically curved photocathodes. By this measure, the distinct non-linearity between the output signals of the phototubes and the actual position of the scintillation in the scintillation crystal, as observed in plane photocathodes, is removed. The distances between the photomultipliers and the scintillation crystal can thus be kept very small whereby an improved statistic and lower noise can be obtained. Furthermore, thicker crystals can be used whereby the efficiency in the determination of higher energies is increased. The electronic signal processing to the reproduction of the nuclide distribution in the body is described in detail. (ORU/LH) [de

  8. A modeling of fuzzy logic controller on gamma scanning device

    Arjoni Amir

    2010-01-01

    Modeling and simulation of controller to set the high position and direction of the source of gamma radiation isotope Co-60 and Nal(TL) detector of gamma scanning device by using fuzzy logic controller FLC have been done. The high positions and in the right direction of gamma radiation and Nal (TI) detector obtained the optimal enumeration. The counting data obtained from gamma scanning device counting system is affected by the instability of high position and direction of the gamma radiation source and Nal(TI) detector or the height and direction are not equal between the gamma radiation source and Nal(TI) detector. Assumed a high position and direction of radiation sources can be fixed while the high position detector h (2, 1,0, -1, -2) can be adjusted up and down and the detector can be changed direction to the left or right angle ω (2, 1 , 0, -1, -2) when the position and direction are no longer aligned with the direction of the source of gamma radiation, the counting results obtained will not be optimal. Movement detector direction towards the left or right and the high detector arranged by the DC motor using fuzzy logic control in order to obtain the amount of output fuzzy logic control which forms the optimal output quantity count. The variation of height difference h between the source position of the gamma radiation detector and change direction with the detector angle ω becomes the input variable membership function (member function) whereas the fuzzy logic for the output variable membership function of fuzzy logic control output is selected scale fuzzy logic is directly proportional to the amount of optimal counting. From the simulation results obtained by the relationship between the amount of data output variable of fuzzy logic controller and the amount of data input variable height h and direction detector ω is depicted in graphical form surface. (author)

  9. High-speed automated NDT device for niobium plate using scanning laser acoustic microscopy

    Oravecz, M.G.; Yu, B.Y.; Riney, K.; Kessler, L.W.; Padamsee, H.

    1988-01-01

    This paper presents a nondestructive testing (NDT) device which rapidly and automatically identifies defects throughout the volume of a 23.4 cm x 23.4 cm x 0.3 cm, pure niobium plate using Scanning Laser Acoustic Microscope (SLAM), high-resolution, 60 MHz, ultrasonic images. A principle advantage of the SLAM technique is that it combines a video scan rate with a high scan density (130 lines/mm at 60 MHz). To automate the inspection system they integrated under computer control the following: the SLAM RS-170/330 video output, a computerized XY plate scanner, a real-time video digitizer/integrator, a computer algorithm for defect detection, a digital mass storage device, and a hardcopy output device. The key element was development of an efficient, reliable defect detection algorithm using a variance filter with a locally determined threshold. This algorithm is responsible for recognizing valid flaws in the midst of random texture. This texture was seen throughout the acoustic images and was caused by the niobium microstructure. The images, as analyzed, contained 128 x 120 pixels with 64 grey levels per pixel. This system allows economical inspection of the large quantities (eg. 100 tons) of material needed for future particle accelerators based on microwave superconductivity. Rapid nondestructive inspection of pure niobium sheet is required because current accelerator performance is largely limited by the quality of commercially available material. Previous work documented critical flaws that are detectable by SLAM techniques. 15 references, 9 figures

  10. An improved three-dimensional non-scanning laser imaging system based on digital micromirror device

    Xia, Wenze; Han, Shaokun; Lei, Jieyu; Zhai, Yu; Timofeev, Alexander N.

    2018-01-01

    Nowadays, there are two main methods to realize three-dimensional non-scanning laser imaging detection, which are detection method based on APD and detection method based on Streak Tube. However, the detection method based on APD possesses some disadvantages, such as small number of pixels, big pixel interval and complex supporting circuit. The detection method based on Streak Tube possesses some disadvantages, such as big volume, bad reliability and high cost. In order to resolve the above questions, this paper proposes an improved three-dimensional non-scanning laser imaging system based on Digital Micromirror Device. In this imaging system, accurate control of laser beams and compact design of imaging structure are realized by several quarter-wave plates and a polarizing beam splitter. The remapping fiber optics is used to sample the image plane of receiving optical lens, and transform the image into line light resource, which can realize the non-scanning imaging principle. The Digital Micromirror Device is used to convert laser pulses from temporal domain to spatial domain. The CCD with strong sensitivity is used to detect the final reflected laser pulses. In this paper, we also use an algorithm which is used to simulate this improved laser imaging system. In the last, the simulated imaging experiment demonstrates that this improved laser imaging system can realize three-dimensional non-scanning laser imaging detection.

  11. Optimal alignment of mirror based pentaprisms for scanning deflectometric devices

    Barber, Samuel K.; Geckeler, Ralf D.; Yashchuk, Valeriy V.; Gubarev, Mikhail V.; Buchheim, Jana; Siewert, Frank; Zeschke, Thomas

    2011-03-04

    In the recent work [Proc. of SPIE 7801, 7801-2/1-12 (2010), Opt. Eng. 50(5) (2011), in press], we have reported on improvement of the Developmental Long Trace Profiler (DLTP), a slope measuring profiler available at the Advanced Light Source Optical Metrology Laboratory, achieved by replacing the bulk pentaprism with a mirror based pentaprism (MBPP). An original experimental procedure for optimal mutual alignment of the MBPP mirrors has been suggested and verified with numerical ray tracing simulations. It has been experimentally shown that the optimally aligned MBPP allows the elimination of systematic errors introduced by inhomogeneity of the optical material and fabrication imperfections of the bulk pentaprism. In the present article, we provide the analytical derivation and verification of easily executed optimal alignment algorithms for two different designs of mirror based pentaprisms. We also provide an analytical description for the mechanism for reduction of the systematic errors introduced by a typical high quality bulk pentaprism. It is also shown that residual misalignments of an MBPP introduce entirely negligible systematic errors in surface slope measurements with scanning deflectometric devices.

  12. THz Wave Propagation on Strip Lines: Devices, Properties, and Applications

    Y. Kadoya

    2008-06-01

    Full Text Available We report the propagation characteristics of THz pulses on micro-strip-lines and coplanar strip-lines, in which low permittivity polymer materials are used as the dielectric layer or the substrate. As a result of the low attenuation and small dispersion in the devices, the spectral width up to 3 THz can be achieved even after the 1 mm propagation. Spectroscopic characterizations of liquid or powder specimens are demonstrated using the devices. We also show a possibility of realizing a very low attenuation using a quadrupole mode in three strip coplanar lines on the polymer substrate.

  13. Side-Scan-Sonar Lines for Hudson River, NY

    National Oceanic and Atmospheric Administration, Department of Commerce — Side Scan Sonar and Subbottom Profiler Tracklines. Data was collected November 5 to December 15, 2009, in the estuary north from Saugerties to Troy. Fugro utilized...

  14. High-speed adaptive optics line scan confocal retinal imaging for human eye.

    Lu, Jing; Gu, Boyu; Wang, Xiaolin; Zhang, Yuhua

    2017-01-01

    Continuous and rapid eye movement causes significant intraframe distortion in adaptive optics high resolution retinal imaging. To minimize this artifact, we developed a high speed adaptive optics line scan confocal retinal imaging system. A high speed line camera was employed to acquire retinal image and custom adaptive optics was developed to compensate the wave aberration of the human eye's optics. The spatial resolution and signal to noise ratio were assessed in model eye and in living human eye. The improvement of imaging fidelity was estimated by reduction of intra-frame distortion of retinal images acquired in the living human eyes with frame rates at 30 frames/second (FPS), 100 FPS, and 200 FPS. The device produced retinal image with cellular level resolution at 200 FPS with a digitization of 512×512 pixels/frame in the living human eye. Cone photoreceptors in the central fovea and rod photoreceptors near the fovea were resolved in three human subjects in normal chorioretinal health. Compared with retinal images acquired at 30 FPS, the intra-frame distortion in images taken at 200 FPS was reduced by 50.9% to 79.7%. We demonstrated the feasibility of acquiring high resolution retinal images in the living human eye at a speed that minimizes retinal motion artifact. This device may facilitate research involving subjects with nystagmus or unsteady fixation due to central vision loss.

  15. Scanning or treating device for smooth curved surface

    Gemma, A.

    1988-01-01

    This robot for scanning or treating a smooth curved surface is made by a vehicle moving predeterminately on the surface, this vehicle having mobil grips. A support arm is attached to the vehicle by a swivel and fixed at the center of the curvature. It is orientable parralel to the axes of legs of the vehicle near the center. Scanning or treatment systems for the surface are fixed on the vehicle. Drives and control systems for the vehicle and treatment or scanning system are provided [fr

  16. Synchronized control of spiral CT scan for security inspection device

    Wang Jue; Jiang Zenghui; Wang Fuquan

    2008-01-01

    In security inspection system of spiral CT, the synchronization between removing and rotating, and the scan synchronization between rotating and sampling influence quality of image reconstruction, so it is difficulty and important that how to realize synchronized scan. According to the controlling demand of multi-slice Spiral CT, the method to realize synchronized scan is given. a synchronized control system is designed, in which we use a industrial PC as the control computer, use magnetic grids as position detectors, use alternating current servo motor and roller motor as drivers respectively drive moving axis and rotating axis. This method can solve the problem of synchronized scan, and has a feasibility and value of use. (authors)

  17. On-line pressure measurement using scanning systems

    Morss, A.G.; Watson, A.P.

    1978-08-01

    Data collection methods can be improved significantly by using pressure scanning systems in conjunction with transducers for the measurement of pressure distribution in fluid flow rigs. However, the response of pressure transducers to the slight random pressure fluctuations that occur in practice can cause some measurement problems, especially for accurate work. The nature of these pressure fluctuations is examined and suitable analysis techniques are recommended. Results obtained using these techniques are presented. It is concluded that by using the correct techniques pressure transducer systems can be used to measure pressure distributions accurately and are sufficiently sensitive to measure very small systematic effects with great precision. (author)

  18. A study on Computer-controlled Ultrasonic Scanning Device

    Huh, H.; Park, C. S.; Hong, S. S.; Park, J. H.

    1989-01-01

    Since the nuclear power plants in Korea have been operated in 1979, the nondestructive testing (NDT) of pressure vessels and/or piping welds plays an important role for maintaining the safety and integrity of the plants. Ultrasonic method is superior to the other NDT method in the viewpoint of the detectability of small flaw and accuracy to determine the locations, sizes, orientations, and shapes. As the service time of the nuclear power plants is increased, the radiation level from the components is getting higher. In order to get more quantitative and reliable results and secure the inspector from the exposure to high radiation level, automation of the ultrasonic equipment has been one of the important research and development(R and D) subject. In this research, it was attempted to visualize the shape of flaws presented inside the specimen using a Modified C-Scan technique. In order to develop Modified C-Scan technique, an automatic ultrasonic scanner and a module to control the scanner were designed and fabricated. IBM-PC/XT was interfaced to the module to control the scanner. Analog signals from the SONIC MARK II were digitized by Analog-Digital Converter(ADC 0800) for Modified C-Scan display. A computer program has been developed and has capability of automatic data acquisition and processing from the digital data, which consist of maximum amplitudes in each gate range and locations. The data from Modified C-Scan results was compared with shape from artificial defects using the developed system. Focal length of focused transducer was measured. The automatic ultrasonic equipment developed through this study is essential for more accurate, reliable, and repeatable ultrasonic experiments. If the scanner are modified to meet to appropriate purposes, it can be applied to automation of ultrasonic examination of nuclear power plants and helpful to the research on ultrasonic characterization of the materials

  19. Radionuclide scanning after total knee replacement: correlation with pain and radiolucent lines. A prospective study

    Duus, B R; Boeckstyns, M; Kjaer, L

    1987-01-01

    The authors examined the relationships among Tc-99m radionuclide bone scan findings, pain, and radiolucent lines in 35 postsurgical knees. Our prospective study included bone scans, as well as radiographic and clinical examination three, seven, and 12 months after knee replacement surgery in 35...... and nonpainful knees, and the degree of isotope uptake did not correlate with the development of radiolucent lines around the prosthetic components....

  20. Determination of line edge roughness in low-dose top-down scanning electron microscopy images

    Verduin, T.; Kruit, P.; Hagen, C.W.

    2014-01-01

    We investigated the off-line metrology for line edge roughness (LER) determination by using the discrete power spectral density (PSD). The study specifically addresses low-dose scanning electron microscopy (SEM) images in order to reduce the acquisition time and the risk of resist shrinkage. The

  1. Line-scan macro-scale Raman chemical imaging for authentication of powdered foods and ingredients

    Adulteration and fraud for powdered foods and ingredients are rising food safety risks that threaten consumers’ health. In this study, a newly developed line-scan macro-scale Raman imaging system using a 5 W 785 nm line laser as excitation source was used to authenticate the food powders. The system...

  2. Line-Scan Hyperspectral Imaging Techniques for Food Safety and Quality Applications

    Jianwei Qin

    2017-01-01

    Full Text Available Hyperspectral imaging technologies in the food and agricultural area have been evolving rapidly over the past 15 years owing to tremendous interest from both academic and industrial fields. Line-scan hyperspectral imaging is a major method that has been intensively researched and developed using different physical principles (e.g., reflectance, transmittance, fluorescence, Raman, and spatially resolved spectroscopy and wavelength regions (e.g., visible (VIS, near infrared (NIR, and short-wavelength infrared (SWIR. Line-scan hyperspectral imaging systems are mainly developed and used for surface inspection of food and agricultural products using area or line light sources. Some of these systems can also be configured to conduct spatially resolved spectroscopy measurements for internal or subsurface food inspection using point light sources. This paper reviews line-scan hyperspectral imaging techniques, with introduction, demonstration, and summarization of existing and emerging techniques for food and agricultural applications. The main topics include related spectroscopy techniques, line-scan measurement methods, hardware components and systems, system calibration methods, and spectral and image analysis techniques. Applications in food safety and quality are also presented to reveal current practices and future trends of line-scan hyperspectral imaging techniques.

  3. 3D scan line method for identifying void fabric of granular materials

    Theocharis Alexandros I.

    2017-01-01

    Full Text Available Among other processes measuring the void phase of porous or fractured media, scan line approach is a simplified “graphical” method, mainly used in image processing related procedures. In soil mechanics, the application of scan line method is related to the soil fabric, which is important in characterizing the anisotropic mechanical response of soils. Void fabric is of particular interest, since graphical approaches are well defined experimentally and most of them can also be easily used in numerical experiments, like the scan line method. This is in contrast to the definition of fabric based on contact normal vectors that are extremely difficult to determine, especially considering physical experiments. The scan line method has been proposed by Oda et al [1] and implemented again by Ghedia and O’Sullivan [2]. A modified method based on DEM analysis instead of image measurements of fabric has been previously proposed and implemented by the authors in a 2D scheme [3-4]. In this work, a 3D extension of the modified scan line definition is presented using PFC 3D®. The results show clearly similar trends with the 2D case and the same behaviour of fabric anisotropy is presented.

  4. Laser line scan underwater imaging by complementary metal-oxide-semiconductor camera

    He, Zhiyi; Luo, Meixing; Song, Xiyu; Wang, Dundong; He, Ning

    2017-12-01

    This work employs the complementary metal-oxide-semiconductor (CMOS) camera to acquire images in a scanning manner for laser line scan (LLS) underwater imaging to alleviate backscatter impact of seawater. Two operating features of the CMOS camera, namely the region of interest (ROI) and rolling shutter, can be utilized to perform image scan without the difficulty of translating the receiver above the target as the traditional LLS imaging systems have. By the dynamically reconfigurable ROI of an industrial CMOS camera, we evenly divided the image into five subareas along the pixel rows and then scanned them by changing the ROI region automatically under the synchronous illumination by the fun beams of the lasers. Another scanning method was explored by the rolling shutter operation of the CMOS camera. The fun beam lasers were turned on/off to illuminate the narrow zones on the target in a good correspondence to the exposure lines during the rolling procedure of the camera's electronic shutter. The frame synchronization between the image scan and the laser beam sweep may be achieved by either the strobe lighting output pulse or the external triggering pulse of the industrial camera. Comparison between the scanning and nonscanning images shows that contrast of the underwater image can be improved by our LLS imaging techniques, with higher stability and feasibility than the mechanically controlled scanning method.

  5. Device for remote control of monitoring of a conveyor line

    Shubin, N F; Rybak, Yu I

    1981-01-01

    The known device under mine conditions because of the decrease of resistance of the insulation of the current-carrying lines of the transfer line does not guarantee reliable protection from false triggering. The purpose of the invention is to improve the reliability of monitoring and control by improving interference-resistance of the device. This goal is achieved because the compensation block is equipped with a transistor, seven diodes, three stabilitrons and resistors united into two compensation circuits which are connected in parallel. The first of them is formed by two stabilitrons connected in series, where the cathode of one of them through a resistor and the counter-connected first diode is connected to a common lead and to the first pole of the block of monitoring and control. The anode of the other through the second counter-connected diode is connected to the second pole of the block of monitoring and control. The second compensation circuit is formed of a transistor, whose collector is connected to the common lead. The emitter is connected through the resistor to the cathode of the third diode whose anode is connected to the lead of the communications line and to the anodes of the fourth diode directly, and the fifth through the resistor, and with the cathode of the third stabilitron whose anode is connected to the transistor base and through the resistor to the common lead. The cathode of the fourth diode is connected to the common point of the first and second stabilitrons through the resistor, connected through the sixth diode, connected by cathode to the cathode of the fourth diode, parallel to the information block. The cathode of the fifth diode is connected to the anode of the second diode, and the second pole of the block of monitoring and control is connected to the communications lead through the seventh diode, connected counter to the fourth and fifth diodes.

  6. Scan-Less Line Field Optical Coherence Tomography, with Automatic Image Segmentation, as a Measurement Tool for Automotive Coatings

    Samuel Lawman

    2017-04-01

    Full Text Available The measurement of the thicknesses of layers is important for the quality assurance of industrial coating systems. Current measurement techniques only provide a limited amount of information. Here, we show that spectral domain Line Field (LF Optical Coherence Tomography (OCT is able to return to the user a cross sectional B-Scan image in a single shot with no mechanical moving parts. To reliably extract layer thicknesses from such images of automotive paint systems, we present an automatic graph search image segmentation algorithm. To show that the algorithm works independently of the OCT device, the measurements are repeated with a separate time domain Full Field (FF OCT system. This gives matching mean thickness values within the standard deviations of the measured thicknesses across each B-Scan image. The combination of an LF-OCT with graph search segmentation is potentially a powerful technique for the quality assurance of non-opaque industrial coating layers.

  7. Ultrasonic unit for line-by-line ultrasonic scanning of bodies

    Soldner, R.

    1978-01-01

    The ultrasonic unit for medical diagnostics operates by the sectorial scanning principle, which avoids direct coupling of the transducer head to the surface of the body. For this purpose, several transmitter/receiver units (approx. 100) are arranged on a partial ring of a circular arc and the ultrasonic beams, which can be triggered sequentially in time, are directed at a common intersection behind the ultrasonic window of the unit, i.e., outside the unit. A mechanical system is employed to set and adjust the partial ring carrying the transmitter/receiver units. (DG) [de

  8. Optical scanning holography based on compressive sensing using a digital micro-mirror device

    A-qian, Sun; Ding-fu, Zhou; Sheng, Yuan; You-jun, Hu; Peng, Zhang; Jian-ming, Yue; xin, Zhou

    2017-02-01

    Optical scanning holography (OSH) is a distinct digital holography technique, which uses a single two-dimensional (2D) scanning process to record the hologram of a three-dimensional (3D) object. Usually, these 2D scanning processes are in the form of mechanical scanning, and the quality of recorded hologram may be affected due to the limitation of mechanical scanning accuracy and unavoidable vibration of stepper motor's start-stop. In this paper, we propose a new framework, which replaces the 2D mechanical scanning mirrors with a Digital Micro-mirror Device (DMD) to modulate the scanning light field, and we call it OSH based on Compressive Sensing (CS) using a digital micro-mirror device (CS-OSH). CS-OSH can reconstruct the hologram of an object through the use of compressive sensing theory, and then restore the image of object itself. Numerical simulation results confirm this new type OSH can get a reconstructed image with favorable visual quality even under the condition of a low sample rate.

  9. Ultrasound line-by-line scanning method of spatial-temporal active cavitation mapping for high-intensity focused ultrasound.

    Ding, Ting; Zhang, Siyuan; Fu, Quanyou; Xu, Zhian; Wan, Mingxi

    2014-01-01

    This paper presented an ultrasound line-by-line scanning method of spatial-temporal active cavitation mapping applicable in a liquid or liquid filled tissue cavities exposed by high-intensity focused ultrasound (HIFU). Scattered signals from cavitation bubbles were obtained in a scan line immediately after one HIFU exposure, and then there was a waiting time of 2 s long enough to make the liquid back to the original state. As this pattern extended, an image was built up by sequentially measuring a series of such lines. The acquisition of the beamformed radiofrequency (RF) signals for a scan line was synchronized with HIFU exposure. The duration of HIFU exposure, as well as the delay of the interrogating pulse relative to the moment while HIFU was turned off, could vary from microseconds to seconds. The feasibility of this method was demonstrated in tap-water and a tap-water filled cavity in the tissue-mimicking gelatin-agar phantom as capable of observing temporal evolutions of cavitation bubble cloud with temporal resolution of several microseconds, lateral and axial resolution of 0.50 mm and 0.29 mm respectively. The dissolution process of cavitation bubble cloud and spatial distribution affected by cavitation previously generated were also investigated. Although the application is limited by the requirement for a gassy fluid (e.g. tap water, etc.) that allows replenishment of nuclei between HIFU exposures, the technique may be a useful tool in spatial-temporal cavitation mapping for HIFU with high precision and resolution, providing a reference for clinical therapy. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Miniature in vivo MEMS-based line-scanned dual-axis confocal microscope for point-of-care pathology

    Yin, C.; Glaser, A.K.; Leigh, S. Y.; Chen, Y.; Wei, L.; Pillai, P. C. S.; Rosenberg, M. C.; Abeytunge, S.; Peterson, G.; Glazowski, C.; Sanai, N.; Mandella, M. J.; Rajadhyaksha, M.; Liu, J. T. C.

    2016-01-01

    There is a need for miniature optical-sectioning microscopes to enable in vivo interrogation of tissues as a real-time and noninvasive alternative to gold-standard histopathology. Such devices could have a transformative impact for the early detection of cancer as well as for guiding tumor-resection procedures. Miniature confocal microscopes have been developed by various researchers and corporations to enable optical sectioning of highly scattering tissues, all of which have necessitated various trade-offs in size, speed, depth selectivity, field of view, resolution, image contrast, and sensitivity. In this study, a miniature line-scanned (LS) dual-axis confocal (DAC) microscope, with a 12-mm diameter distal tip, has been developed for clinical point-of-care pathology. The dual-axis architecture has demonstrated an advantage over the conventional single-axis confocal configuration for reducing background noise from out-of-focus and multiply scattered light. The use of line scanning enables fast frame rates (16 frames/sec is demonstrated here, but faster rates are possible), which mitigates motion artifacts of a hand-held device during clinical use. We have developed a method to actively align the illumination and collection beams in a DAC microscope through the use of a pair of rotatable alignment mirrors. Incorporation of a custom objective lens, with a small form factor for in vivo clinical use, enables our device to achieve an optical-sectioning thickness and lateral resolution of 2.0 and 1.1 microns respectively. Validation measurements with reflective targets, as well as in vivo and ex vivo images of tissues, demonstrate the clinical potential of this high-speed optical-sectioning microscopy device. PMID:26977337

  11. Deformable motion reconstruction for scanned proton beam therapy using on-line x-ray imaging

    Zhang, Ye; Knopf, A; Tanner, Colby; Boye, Dirk; Lomax, Antony J.

    2013-01-01

    Organ motion is a major problem for any dynamic radiotherapy delivery technique, and is particularly so for spot scanned proton therapy. On the other hand, the use of narrow, magnetically deflected proton pencil beams is potentially an ideal delivery technique for tracking tumour motion on-line. At

  12. Laser sintering of metal powders on top of sintered layers under multiple-line laser scanning

    Xiao Bin; Zhang Yuwen

    2007-01-01

    A three-dimensional numerical model for multiple-line sintering of loose powders on top of multiple sintered layers under the irradiation of a moving Gaussian laser beam is carried out. The overlaps between vertically deposited layers and adjacent lines which strengthen bonding are taken into account. The energy equation is formulated using the temperature transforming model and solved by the finite volume method. The effects of the number of the existing sintered layers, porosity and initial temperature coupled with the optimal combination laser intensity and scanning velocity are presented. The results show that the liquid pool moves slightly towards the negative scanning direction and the shape of the liquid pool becomes shallower with higher scanning velocity. A higher laser intensity is needed to achieve the required overlaps when the number of the existing sintered layers increases. Increasing porosity or initial temperature enhances the sintering process and thus less intensity is needed for the overlap requirement

  13. Scan direction induced charging dynamics and the application for detection of gate to S/D shorts in logic devices

    Lei, Ming; Tian, Qing; Wu, Kevin; Zhao, Yan

    2016-03-01

    Gate to source/drain (S/D) short is the most common and detrimental failure mechanism for advanced process technology development in Metal-Oxide-Semiconductor-Field-Effect-Transistor (MOSFET) device manufacturing. Especially for sub-1Xnm nodes, MOSFET device is more vulnerable to gate-S/D shorts due to the aggressive scaling. The detection of this kind of electrical short defect is always challenging for in-line electron beam inspection (EBI), especially new shorting mechanisms on atomic scale due to new material/process flow implementation. The second challenge comes from the characterization of the shorts including identification of the exact shorting location. In this paper, we demonstrate unique scan direction induced charging dynamics (SDCD) phenomenon which stems from the transistor level response from EBI scan at post metal contact chemical-mechanical planarization (CMP) layers. We found that SDCD effect is exceptionally useful for gate-S/D short induced voltage contrast (VC) defect detection, especially for identification of shorting locations. The unique SDCD effect signatures of gate-S/D shorts can be used as fingerprint for ground true shorting defect detection. Correlation with other characterization methods on the same defective location from EBI scan shows consistent results from various shorting mechanism. A practical work flow to implement the application of SDCD effect for in-line EBI monitor of critical gate-S/D short defects is also proposed, together with examples of successful application use cases which mostly focus on static random-access memory (SRAM) array regions. Although the capability of gate-S/D short detection as well as expected device response is limited to passing transistors and pull-down transistors due to the design restriction from standard 6-cell SRAM structure, SDCD effect is proven to be very effective for gate-S/D short induced VC defect detection as well as yield learning for advanced technology development.

  14. A novel near real-time laser scanning device for geometrical determination of pleural cavity surface.

    Kim, Michele M; Zhu, Timothy C

    2013-02-02

    During HPPH-mediated pleural photodynamic therapy (PDT), it is critical to determine the anatomic geometry of the pleural surface quickly as there may be movement during treatment resulting in changes with the cavity. We have developed a laser scanning device for this purpose, which has the potential to obtain the surface geometry in real-time. A red diode laser with a holographic template to create a pattern and a camera with auto-focusing abilities are used to scan the cavity. In conjunction with a calibration with a known surface, we can use methods of triangulation to reconstruct the surface. Using a chest phantom, we are able to obtain a 360 degree scan of the interior in under 1 minute. The chest phantom scan was compared to an existing CT scan to determine its accuracy. The laser-camera separation can be determined through the calibration with 2mm accuracy. The device is best suited for environments that are on the scale of a chest cavity (between 10cm and 40cm). This technique has the potential to produce cavity geometry in real-time during treatment. This would enable PDT treatment dosage to be determined with greater accuracy. Works are ongoing to build a miniaturized device that moves the light source and camera via a fiber-optics bundle commonly used for endoscopy with increased accuracy.

  15. Scanning and/or treating surface device for weak bending radius cylindrical airlock

    Gemma, A.

    1988-01-01

    The device for scanning or treating the surface of a weak bending cylindrical airlock has a support mounted on the airlock outside flange, a central mast perpendicular to the support mounted to rotate about its axis, a geared motor turning the mast, an exploration or treatment tool fixed to the mast and a controller for the motor and the tool [fr

  16. 76 FR 52970 - In the Matter of Certain Biometric Scanning Devices, Components Thereof, Associated Software, and...

    2011-08-24

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-720] In the Matter of Certain Biometric... 17, 2010 based on a complaint filed on May 11, 2010, by Cross Match Technologies, Inc. (``Cross Match... certain biometric scanning devices, components thereof, associated software, and products containing the...

  17. 75 FR 34482 - Certain Biometric Scanning Devices, Components Thereof, Associated Software, and Products...

    2010-06-17

    ... INTERNATIONAL TRADE COMMISSION [Inv. No. 337-TA-720] Certain Biometric Scanning Devices... Cross Match Technologies, Inc. of Palm Beach Gardens, Florida. An amended complaint was filed on May 26..., the sale for importation, and the sale within the United States after importation of certain biometric...

  18. Multidirectional Scanning Model, MUSCLE, to Vectorize Raster Images with Straight Lines

    Ibrahim Baz

    2008-04-01

    Full Text Available This paper presents a new model, MUSCLE (Multidirectional Scanning for Line Extraction, for automatic vectorization of raster images with straight lines. The algorithm of the model implements the line thinning and the simple neighborhood methods to perform vectorization. The model allows users to define specified criteria which are crucial for acquiring the vectorization process. In this model, various raster images can be vectorized such as township plans, maps, architectural drawings, and machine plans. The algorithm of the model was developed by implementing an appropriate computer programming and tested on a basic application. Results, verified by using two well known vectorization programs (WinTopo and Scan2CAD, indicated that the model can successfully vectorize the specified raster data quickly and accurately.

  19. In situ scanning tunneling microscope tip treatment device for spin polarization imaging

    Li, An-Ping [Oak Ridge, TN; Jianxing, Ma [Oak Ridge, TN; Shen, Jian [Knoxville, TN

    2008-04-22

    A tip treatment device for use in an ultrahigh vacuum in situ scanning tunneling microscope (STM). The device provides spin polarization functionality to new or existing variable temperature STM systems. The tip treatment device readily converts a conventional STM to a spin-polarized tip, and thereby converts a standard STM system into a spin-polarized STM system. The tip treatment device also has functions of tip cleaning and tip flashing a STM tip to high temperature (>2000.degree. C.) in an extremely localized fashion. Tip coating functions can also be carried out, providing the tip sharp end with monolayers of coating materials including magnetic films. The device is also fully compatible with ultrahigh vacuum sample transfer setups.

  20. Characterization of Line Nanopatterns on Positive Photoresist Produced by Scanning Near-Field Optical Microscope

    Sadegh Mehdi Aghaei

    2015-01-01

    Full Text Available Line nanopatterns are produced on the positive photoresist by scanning near-field optical microscope (SNOM. A laser diode with a wavelength of 450 nm and a power of 250 mW as the light source and an aluminum coated nanoprobe with a 70 nm aperture at the tip apex have been employed. A neutral density filter has been used to control the exposure power of the photoresist. It is found that the changes induced by light in the photoresist can be detected by in situ shear force microscopy (ShFM, before the development of the photoresist. Scanning electron microscope (SEM images of the developed photoresist have been used to optimize the scanning speed and the power required for exposure, in order to minimize the final line width. It is shown that nanometric lines with a minimum width of 33 nm can be achieved with a scanning speed of 75 µm/s and a laser power of 113 mW. It is also revealed that the overexposure of the photoresist by continuous wave laser generated heat can be prevented by means of proper photoresist selection. In addition, the effects of multiple exposures of nanopatterns on their width and depth are investigated.

  1. Device localization and dynamic scan plane selection using a wireless MRI detector array

    Riffe, Matthew J.; Yutzy, Stephen R.; Jiang, Yun; Twieg, Michael D.; Blumenthal, Colin J.; Hsu, Daniel P.; Pan, Li; Gilson, Wesley D.; Sunshine, Jeffrey L.; Flask, Christopher A.; Duerk, Jeffrey L.; Nakamoto, Dean; Gulani, Vikas; Griswold, Mark A.

    2013-01-01

    Purpose A prototype wireless guidance device using single sideband amplitude modulation (SSB) is presented for a 1.5T MRI system. Methods The device contained three fiducial markers each mounted to an independent receiver coil equipped with wireless SSB technology. Acquiring orthogonal projections of these markers determined the position and orientation of the device, which was used to define the scan plane for a subsequent image acquisition. Device localization and scan plane update required approximately 30 ms, so it could be interleaved with high temporal resolution imaging. Since the wireless device is used for localization and doesn’t require full imaging capability, the design of the SSB wireless system was simplified by allowing an asynchronous clock between the transmitter and receiver. Results When coupled to a high readout bandwidth, the error caused by the lack of a shared frequency reference was quantified to be less than one pixel (0.78 mm) in the projection acquisitions. Image-guidance with the prototype was demonstrated with a phantom where a needle was successfully guided to a target and contrast was delivered. Conclusion The feasibility of active tracking with a wireless detector array is demonstrated. Wireless arrays could be incorporated into devices to assist in image-guided procedures. PMID:23900921

  2. Line scan analysis of the component of Ru porcelain by SRXRF method

    Zhu Jian; Mao Zhenwei; Yang Yimin; Feng Min; Wang Changsui; Sun Xinmin; Guo Musen; Huang Yuying; He Wei

    2002-01-01

    The technique of the SRXRF line scan analysis was used to measure contents of 11 elements at the broken plane of the Ru porcelain from porcelain glaze to body. It is found that there exists a great different layer of contents of elements between the porcelain glaze and body. The mechanism may be that in the process of firing the porcelain, materials of glass-glaze of porcelain glaze infiltrate into the surface of porcelain body, that could fit the phenomenon of observation by different microscopes (stereomicroscope, polarizing microscope and scanning electron microscope)

  3. Measuring a narrow Bessel beam spot by scanning a charge-coupled device (CCD) pixel

    Tiwari, S K; Ram, S P; Jayabalan, J; Mishra, S R

    2010-01-01

    By scanning a charge-coupled device (CCD) camera transverse to the beam axis and observing the variation in counts on a marked pixel, we demonstrate that we can measure a laser beam spot size smaller than the size of the CCD-pixel. We find this method particularly attractive for measuring the size of central spot of a Bessel beam, for which the established scanning knife-edge method does not work appropriately because of the large contribution of the rings surrounding the central spot to the signal

  4. Line scanning analysis of Dilingtou Yue porcelain in Southern Song Dynasty by SRXRF method

    Zhu Shoumei; Mao Zhenwei; Feng Min; Zhu Jian; Ling Xue; Sheng Yueming; Huang Yuying; He Wei

    2004-01-01

    The SRXRF line scanning analysis technique was used to measure the elements' content in the Dilingtou Yue porcelain sherd of Southern Song Dynasty from glaze to body. It is found that there exists a middle layer between the porcelain glaze and body. And a line scanning analysis comparison was made with the Ru porcelain in Northern Song Dynasty. There are some differences between them and the middle layer of Dilingtou Yue sherd is a little thinner than the Ru sherd's. And elements' content distributions in glaze are different from Ru porcelain's and the changes of contents from the surface to the inner side of glaze are undulatory. The results indicate that the differences may result from the different materials of body and the different kilns. (authors)

  5. Phase Error Caused by Speed Mismatch Analysis in the Line-Scan Defect Detection by Using Fourier Transform Technique

    Eryi Hu

    2015-01-01

    Full Text Available The phase error caused by the speed mismatch issue is researched in the line-scan images capturing 3D profile measurement. The experimental system is constructed by a line-scan CCD camera, an object moving device, a digital fringe pattern projector, and a personal computer. In the experiment procedure, the detected object is moving relative to the image capturing system by using a motorized translation stage in a stable velocity. The digital fringe pattern is projected onto the detected object, and then the deformed patterns are captured and recorded in the computer. The object surface profile can be calculated by the Fourier transform profilometry. However, the moving speed mismatch error will still exist in most of the engineering application occasion even after an image system calibration. When the moving speed of the detected object is faster than the expected value, the captured image will be compressed in the moving direction of the detected object. In order to overcome this kind of measurement error, an image recovering algorithm is proposed to reconstruct the original compressed image. Thus, the phase values can be extracted much more accurately by the reconstructed images. And then, the phase error distribution caused by the speed mismatch is analyzed by the simulation and experimental methods.

  6. Note: Automated optical focusing on encapsulated devices for scanning light stimulation systems

    Bitzer, L. A.; Benson, N.; Schmechel, R.

    2014-01-01

    Recently, a scanning light stimulation system with an automated, adaptive focus correction during the measurement was introduced. Here, its application on encapsulated devices is discussed. This includes the changes an encapsulating optical medium introduces to the focusing process as well as to the subsequent light stimulation measurement. Further, the focusing method is modified to compensate for the influence of refraction and to maintain a minimum beam diameter on the sample surface

  7. Fabrication of Gate-tunable Graphene Devices for Scanning Tunneling Microscopy Studies with Coulomb Impurities

    Jung, Han Sae; Tsai, Hsin-Zon; Wong, Dillon; Germany, Chad; Kahn, Salman; Kim, Youngkyou; Aikawa, Andrew S.; Desai, Dhruv K.; Rodgers, Griffin F.; Bradley, Aaron J.; Velasco, Jairo; Watanabe, Kenji; Taniguchi, Takashi; Wang, Feng; Zettl, Alex; Crommie, Michael F.

    2015-01-01

    Owing to its relativistic low-energy charge carriers, the interaction between graphene and various impurities leads to a wealth of new physics and degrees of freedom to control electronic devices. In particular, the behavior of graphene’s charge carriers in response to potentials from charged Coulomb impurities is predicted to differ significantly from that of most materials. Scanning tunneling microscopy (STM) and scanning tunneling spectroscopy (STS) can provide detailed information on both the spatial and energy dependence of graphene's electronic structure in the presence of a charged impurity. The design of a hybrid impurity-graphene device, fabricated using controlled deposition of impurities onto a back-gated graphene surface, has enabled several novel methods for controllably tuning graphene’s electronic properties.1-8 Electrostatic gating enables control of the charge carrier density in graphene and the ability to reversibly tune the charge2 and/or molecular5 states of an impurity. This paper outlines the process of fabricating a gate-tunable graphene device decorated with individual Coulomb impurities for combined STM/STS studies.2-5 These studies provide valuable insights into the underlying physics, as well as signposts for designing hybrid graphene devices. PMID:26273961

  8. A novel and compact nanoindentation device for in situ nanoindentation tests inside the scanning electron microscope

    Hu Huang

    2012-03-01

    Full Text Available In situ nanomechanical tests provide a unique insight into mechanical behaviors of materials, such as fracture onset and crack propagation, shear band formation and so on. This paper presents a novel in situ nanoindentation device with dimensions of 103mm×74mm×60mm. Integrating the stepper motor, the piezoelectric actuator and the flexure hinge, the device can realize coarse adjustment of the specimen and precision loading and unloading of the indenter automatically. A novel indenter holder was designed to guarantee that the indenter penetrates into and withdraws from the specimen surface vertically. Closed-loop control of the indentation process was established to solve the problem of nonlinearity of the piezoelectric actuator and to enrich the loading modes. The in situ indentation test of Indium Phosphide (InP inside the scanning electron microscope (SEM was carried out and the experimental result indicates the feasibility of the developed device.

  9. NATO Advanced Study Institute on Scanning Probe Microscopy : Characterization, Nanofabrication and Device Application of Functional Materials

    Vilarinho, Paula Maria; Kingon, Angus; Scanning Probe Microscopy : Characterization, Nanofabrication and Device Application of Functional Materials

    2005-01-01

    As the characteristic dimensions of electronic devices continue to shrink, the ability to characterize their electronic properties at the nanometer scale has come to be of outstanding importance. In this sense, Scanning Probe Microscopy (SPM) is becoming an indispensable tool, playing a key role in nanoscience and nanotechnology. SPM is opening new opportunities to measure semiconductor electronic properties with unprecedented spatial resolution. SPM is being successfully applied for nanoscale characterization of ferroelectric thin films. In the area of functional molecular materials it is being used as a probe to contact molecular structures in order to characterize their electrical properties, as a manipulator to assemble nanoparticles and nanotubes into simple devices, and as a tool to pattern molecular nanostructures. This book provides in-depth information on new and emerging applications of SPM to the field of materials science, namely in the areas of characterisation, device application and nanofabrica...

  10. Novel Automatic Detection of Pleura and B-lines (Comet-Tail Artifacts) on In-Vivo Lung Ultrasound Scans

    Moshavegh, Ramin; Hansen, Kristoffer Lindskov; Møller-Sørensen, Hasse

    2016-01-01

    This paper presents a novel automatic method for detection of B-lines (comet-tail artifacts) in lung ultrasound scans. B-lines are the most commonly used artifacts for analyzing the pulmonary edema. They appear as laser-like vertical beams, which arise from the pleural line and spread down without...

  11. A line scanned light-sheet microscope with phase shaped self-reconstructing beams.

    Fahrbach, Florian O; Rohrbach, Alexander

    2010-11-08

    We recently demonstrated that Microscopy with Self-Reconstructing Beams (MISERB) increases both image quality and penetration depth of illumination beams in strongly scattering media. Based on the concept of line scanned light-sheet microscopy, we present an add-on module to a standard inverted microscope using a scanned beam that is shaped in phase and amplitude by a spatial light modulator. We explain technical details of the setup as well as of the holograms for the creation, positioning and scaling of static light-sheets, Gaussian beams and Bessel beams. The comparison of images from identical sample areas illuminated by different beams allows a precise assessment of the interconnection between beam shape and image quality. The superior propagation ability of Bessel beams through inhomogeneous media is demonstrated by measurements on various scattering media.

  12. Development of a method of testing irradiation devices by gamma scanning inside a research nuclear reactor

    Michel, Francois.

    1975-01-01

    A tridimensional experiment of spectrometry of an irradiation device located inside the reactor Siloe at a place shielded against spurious radiations, is exposed. The automatic scanning system that was developed, makes it possible to fully analyze in about 24 hours, the irradiation device (fuel pin, coolant and structures). The process combined with a 'pre-processing' program allows first partial results to be simultaneously obtained, more refined results being achieved during the next week, using the 'heavy processing'. The irradiation of the device is only interrupted during the compelling duty shutdown of the reactor, the evolution of the device during the successive irradiation cycles being thus followed up without pertubing said evolution. The reproducibility was studied at a local stage for testing the collimation of the detection unit (1% accuracy) and for testing the whole set 'processing measurement and computation' (5% accuracy). The sensitivity has been illustrated by detecting and measuring local singularities inside fuel (pellets), determining the detection efficiency dependence on the radial distribution of fission products and measuring nucleides inside the coolant flow (limiting value 10 -7 ). The accuracy of the method is evaluated at 5% for relative measurement of an experimental device during its in-pile lifetime and as 10% for quantitative absolute measurements [fr

  13. Towards Robust Self-Calibration for Handheld 3d Line Laser Scanning

    Bleier, M.; Nüchter, A.

    2017-11-01

    This paper studies self-calibration of a structured light system, which reconstructs 3D information using video from a static consumer camera and a handheld cross line laser projector. Intersections between the individual laser curves and geometric constraints on the relative position of the laser planes are exploited to achieve dense 3D reconstruction. This is possible without any prior knowledge of the movement of the projector. However, inaccurrately extracted laser lines introduce noise in the detected intersection positions and therefore distort the reconstruction result. Furthermore, when scanning objects with specular reflections, such as glossy painted or metalic surfaces, the reflections are often extracted from the camera image as erroneous laser curves. In this paper we investiagte how robust estimates of the parameters of the laser planes can be obtained despite of noisy detections.

  14. Side-Scan Sonar Image Mosaic Using Couple Feature Points with Constraint of Track Line Positions

    Jianhu Zhao

    2018-06-01

    Full Text Available To obtain large-scale seabed surface image, this paper proposes a side-scan sonar (SSS image mosaic method using couple feature points (CFPs with constraint of track line positions. The SSS geocoded images are firstly used to form a coarsely mosaicked one and the overlapping areas between adjacent strip images can be determined based on geographic information. Inside the overlapping areas, the feature point (FP detection and registration operation are adopted for both strips. According to the detected CFPs and track line positions, an adjustment model is established to accommodate complex local distortions as well as ensure the global stability. This proposed method effectively solves the problem of target ghosting or dislocation and no accumulated errors arise in the mosaicking process. Experimental results show that the finally mosaicked image correctly reflects the object distribution, which is meaningful for understanding and interpreting seabed topography.

  15. Effect of Software Version on the Accuracy of an Intraoral Scanning Device.

    Haddadi, Yasser; Bahrami, Golnosh; Isidor, Flemming

    2018-04-06

    To investigate the impact of software version on the accuracy of an intraoral scanning device. A master tooth was scanned with a high-precision optical scanner and then 10 times with a CEREC Omnicam scanner with software versions 4.4.0 and 4.4.4. Discrepancies were measured using quality control software. Mean deviation for 4.4.0 was 36.2 ± 35 μm and for 4.4.4 was 20.7 ± 14.2 μm (P ≤ .001). Software version has a significant impact on the accuracy of an intraoral scanner. It is important that researchers also publish the software version of scanners when publishing their findings.

  16. Low cost, microcontroller based heating device for multi-wavelength differential scanning fluorimetry.

    Hoeser, Jo; Gnandt, Emmanuel; Friedrich, Thorsten

    2018-01-23

    Differential scanning fluorimetry is a popular method to estimate the stability of a protein in distinct buffer conditions by determining its 'melting point'. The method requires a temperature controlled fluorescence spectrometer or a RT-PCR machine. Here, we introduce a low-budget version of a microcontroller based heating device implemented into a 96-well plate reader that is connected to a standard fluorescence spectrometer. We demonstrate its potential to determine the 'melting point' of soluble and membranous proteins at various buffer conditions.

  17. A design of a high speed dual spectrometer by single line scan camera

    Palawong, Kunakorn; Meemon, Panomsak

    2018-03-01

    A spectrometer that can capture two orthogonal polarization components of s light beam is demanded for polarization sensitive imaging system. Here, we describe the design and implementation of a high speed spectrometer for simultaneous capturing of two orthogonal polarization components, i.e. vertical and horizontal components, of light beam. The design consists of a polarization beam splitter, two polarization-maintain optical fibers, two collimators, a single line-scan camera, a focusing lens, and a reflection blaze grating. The alignment of two beam paths was designed to be symmetrically incident on the blaze side and reverse blaze side of reflection grating, respectively. The two diffracted beams were passed through the same focusing lens and focused on the single line-scan sensors of a CMOS camera. The two spectra of orthogonal polarization were imaged on 1000 pixels per spectrum. With the proposed setup, the amplitude and shape of the two detected spectra can be controlled by rotating the collimators. The technique for optical alignment of spectrometer will be presented and discussed. The two orthogonal polarization spectra can be simultaneously captured at a speed of 70,000 spectra per second. The high speed dual spectrometer can simultaneously detected two orthogonal polarizations, which is an important component for the development of polarization-sensitive optical coherence tomography. The performance of the spectrometer have been measured and analyzed.

  18. Automating data analysis during the inspection of boiler tubes using line scanning thermography

    Ley, Obdulia; Momeni, Sepand; Ostroff, Jason; Godinez, Valery

    2012-05-01

    Failures in boiler waterwalls can occur when a relatively small amount of corrosion and loss of metal have been experienced. This study presents our efforts towards the application of Line Scanning Thermography (LST) for the analysis of thinning in boiler waterwall tubing. LST utilizes a line heat source to thermally excite the surface to be inspected and an infrared detector to record the transient surface temperature increase observed due to the presence of voids, thinning or other defects. In waterwall boiler tubes the defects that can be detected using LST correspond to corrosion pitting, hydrogen damage and wall thinning produced by inadequate burner heating or problems with the water chemistry. In this paper we discuss how the LST technique is implemented to determine thickness from the surface temperature data, and we describe our efforts towards developing a semiautomatic analysis tool to speed up the time between scanning, reporting and implementing repairs. We compare the density of data produced by the common techniques used to assess wall thickness and the data produced by LST.

  19. On-line display used with cathode ray tube film measuring device

    Fortney, L.R.; Robertson, W.J.

    1981-01-01

    An improved display has been developed for use on our computer controlled measuring device (RIPPLE). The device features a television image of the film and a digital presentation on the same X, Y display. The television image is formed using a modified left and right raster scan which can cover 50% more area in the same time as the traditional raster

  20. Backside illuminated CMOS-TDI line scan sensor for space applications

    Cohen, Omer; Ofer, Oren; Abramovich, Gil; Ben-Ari, Nimrod; Gershon, Gal; Brumer, Maya; Shay, Adi; Shamay, Yaron

    2018-05-01

    A multi-spectral backside illuminated Time Delayed Integration Radiation Hardened line scan sensor utilizing CMOS technology was designed for continuous scanning Low Earth Orbit small satellite applications. The sensor comprises a single silicon chip with 4 independent arrays of pixels where each array is arranged in 2600 columns with 64 TDI levels. A multispectral optical filter whose spectral responses per array are adjustable per system requirement is assembled at the package level. A custom 4T Pixel design provides the required readout speed, low-noise, very low dark current, and high conversion gains. A 2-phase internally controlled exposure mechanism improves the sensor's dynamic MTF. The sensor high level of integration includes on-chip 12 bit per pixel analog to digital converters, on-chip controller, and CMOS compatible voltage levels. Thus, the power consumption and the weight of the supporting electronics are reduced, and a simple electrical interface is provided. An adjustable gain provides a Full Well Capacity ranging from 150,000 electrons up to 500,000 electrons per column and an overall readout noise per column of less than 120 electrons. The imager supports line rates ranging from 50 to 10,000 lines/sec, with power consumption of less than 0.5W per array. Thus, the sensor is characterized by a high pixel rate, a high dynamic range and a very low power. To meet a Latch-up free requirement RadHard architecture and design rules were utilized. In this paper recent electrical and electro-optical measurements of the sensor's Flight Models will be presented for the first time.

  1. Reengineering a PC-based System into the Mobile Device Product Line

    Zhang, Weishan; Jarzabek, Stanislaw; Loughran, Neil

    2003-01-01

    There is a growing demand to port existing PC-based software systems to mobile device platforms. Systems running on mobile devices share basic characteristics with their PC-based counterparts, but differ from them in details of user interfaces, application models, etc. Systems running on mobile...... devices must also perform well using less memory than PC-based systems. Mobile devices themselves are different from each other in many ways, too. We describe how we made an existing PC-based City Guide System available on a wide range of mobile devices, in a cost-effective way. We applied "reengineering...... into a product line architecture" approach to achieve the goal. Our product line architecture facilitates reuse via generation. We generate specific City Guide Systems for target platforms including PC, Pocket PC and other mobile devices, from generic meta-components that form the City Guide System product line...

  2. An Intelligent Improvement of Internet-Wide Scan Engine for Fast Discovery of Vulnerable IoT Devices

    Hwankuk Kim

    2018-05-01

    Full Text Available Since 2016, Mirai and Persirai malware have infected hundreds of thousands of Internet of Things (IoT devices and created a massive IoT botnet, which caused distributed denial of service (DDoS attacks. IoT malware targets vulnerable IoT devices, which are vulnerable to security risks. Techniques are needed to prevent IoT devices from being exploited by attackers. However, unlike high-performance PCs, IoT devices are lightweight, low-power, and low-cost, having performance limitations regarding processing and memory, which makes it difficult to install security and anti-malware programs. Recently, several studies have been attempted to quickly search for vulnerable internet-connected devices to solve this real issue. Issues yet to be studied still exist regarding these types of internet-wide scan technologies, such as filtering by security devices and a shortage of collected operating system (OS information. This paper proposes an intelligent internet-wide scan model that improves IP state scanning with advanced internet protocol (IP randomization, reactive protocol (port scanning, and OS fingerprinting scanning, applying k* algorithm in order to find vulnerable IoT devices. Additionally, we describe the experiment’s results compared to the existing internet-wide scan technologies, such as ZMap and Shodan. As a result, the proposed model experimentally shows improved performance. Although we improved the ZMap, the throughput per minute (TPM performance is similar to ZMap without degrading the IP scan throughput and the performance of generating a single IP address is about 118% better than ZMap. In the protocol scan performance experiments, it is about 129% better than the Censys based ZMap, and the performance of OS fingerprinting is better than ZMap, with about 50% accuracy.

  3. Reticle variation influence on manufacturing line and wafer device performance

    Nistler, John L.; Spurlock, Kyle

    1994-01-01

    Cost effective manufacturing of devices at 0.5, 0.35 and 0.25μm geometries will be highly dependent on a companys' ability to obtain an economic return on investment. The high capital investment in equipment and facilities, not to mention the related chemical and wafer costs, for producing 200mm silicon wafers requires aspects of wafer processing to be tightly controlled. Reduction in errors and enhanced yield management requires early correction or avoidance of reticle problems. It is becoming increasingly important to recognize and track all pertinent factors impacting both the technical and financial viability of a wafer manufacturing fabrication area. Reticle related effects on wafer manufacturing can be costly and affect the total quality perceived by the device customer.

  4. Robot calibration with a photogrammetric on-line system using reseau scanning cameras

    Diewald, Bernd; Godding, Robert; Henrich, Andreas

    1994-03-01

    The possibility for testing and calibration of industrial robots becomes more and more important for manufacturers and users of such systems. Exacting applications in connection with the off-line programming techniques or the use of robots as measuring machines are impossible without a preceding robot calibration. At the LPA an efficient calibration technique has been developed. Instead of modeling the kinematic behavior of a robot, the new method describes the pose deviations within a user-defined section of the robot's working space. High- precision determination of 3D coordinates of defined path positions is necessary for calibration and can be done by digital photogrammetric systems. For the calibration of a robot at the LPA a digital photogrammetric system with three Rollei Reseau Scanning Cameras was used. This system allows an automatic measurement of a large number of robot poses with high accuracy.

  5. A License Plate Locating Method Based on Tophat-bothat Changing and Line Scanning

    Hou, P G; Zhao, J; Liu, M

    2006-01-01

    The automatic license plate recognition is an important technique to obtain traffic information, it mixes computer vision, image processing techniques and pattern recognition techniques, it is an important technique in intelligent traffic system. In a vehicle license plate recognition system, plate region detection is the key step before the final recognition. This article introduces the whole process of plate region detection. Top - hat and bot - hat transformation are used for enhancing the image contrast in this paper, and wavelet threshold method is used as image filter, and a improved line scanning is used for plate region detection at last. This method has strong practicability. The experimental results demonstrate that the method introduced in this paper is effective

  6. The Probability of Detection in the Telephone Line of Device of the Unauthorized Removal of Information

    I. V. Svintsov

    2011-06-01

    Full Text Available The article discusses the theory of quantitative description of the possible presence in the telephone line devices unauthorized removal of information, investigated with the help of probability theory.

  7. The signature-based radiation-scanning approach to standoff detection of improvised explosive devices

    Brewer, R.L.; Dunn, W.L.; Heider, S.; Matthew, C.; Yang, X.

    2012-01-01

    The signature-based radiation-scanning technique for detection of improvised explosive devices is described. The technique seeks to detect nitrogen-rich chemical explosives present in a target. The technology compares a set of “signatures” obtained from a test target to a collection of “templates”, sets of signatures for a target that contain an explosive in a specific configuration. Interrogation of nitrogen-rich fertilizer samples, which serve as surrogates for explosives, is shown experimentally to be able to discriminate samples of 3.8 L and larger. - Highlights: ► Signature-based radiation-scanning techniques applied to detection of explosives. ► Nitrogen-rich fertilizer samples served as surrogate explosive samples. ► Signatures of a target compared to collections of templates of surrogate explosives. ► Figure-of-merit determined for neutron and neutron-induced gamma-ray signatures. ► Discrimination of surrogate explosive from inert samples of 3.8 L and larger.

  8. Novel Infiltration Diagnostics based on Laser-line Scanning and Infrared Temperature Field Imaging

    Wang, Xinwei [Iowa State Univ., Ames, IA (United States)

    2017-12-08

    This project targets the building energy efficiency problems induced by building infiltration/leaks. The current infiltration inspection techniques often require extensive visual inspection and/or whole building pressure test. These current techniques cannot meet more than three of the below five criteria of ideal infiltration diagnostics: 1. location and extent diagnostics, 2. building-level application, 3. least surface preparation, 4. weather-proof, and 5. non-disruption to building occupants. These techniques are either too expensive or time consuming, and often lack accuracy and repeatability. They are hardly applicable to facades/facades section. The goal of the project was to develop a novel infiltration diagnostics technology based on laser line-scanning and simultaneous infrared temperature imaging. A laboratory scale experimental setup was designed to mimic a model house of well-defined pressure difference below or above the outside pressure. Algorithms and Matlab-based programs had been developed for recognition of the hole location in infrared images. Our experiment based on laser wavelengths of 450 and 1550 nm and laser beam diameters of 4-25 mm showed that the location of the holes could be identified using laser heating; the diagnostic approach however could not readily distinguish between infiltration and non-infiltration points. To significantly improve the scanning throughput and recognition accuracy, a second approach was explored, developed, and extensively tested. It incorporates a liquid spray on the surface to induce extra phase change cooling effect. In this spray method, we termed it as PECIT (Phase-change Enhanced Cooling Infrared Thermography), phase-change enhanced cooling was used, which significantly amplifies the effect of air flow (infiltration and exfiltration). This heat transfer method worked extremely well to identify infiltration and exfiltration locations with high accuracy and increased throughput. The PECIT technique was

  9. An Automatic Hypothesis of Electrical Lines from Range Scans and Photographs

    Krispel, Ulrich; Ullrich, Torsten; Evers, Henrik Leander

    2016-01-01

    Building information modeling (BIM) with high level of detail and semantic information on buildings throughout their lifetime are getting more and more important for stakeholders in the building domain. Currently, such models are not yet present for the majority of today’s building stock. With in......Building information modeling (BIM) with high level of detail and semantic information on buildings throughout their lifetime are getting more and more important for stakeholders in the building domain. Currently, such models are not yet present for the majority of today’s building stock...... to extract non-visible structures from visible geometric entities. This work uses domain specific geometric and semantic constraints to automatically deduce information that is not directly observable in architectural objects: electrical power supply lines. It utilizes as-built BIM data from scans of indoor...... room. Observable endpoints (sockets and switches) are detected in indoor scenes of buildings using methods from computer vision. The information from the reconstructed BIM model, as well as the detections and the generated installation zones are combined in a graph that represents all likely paths...

  10. Opto-electronic scanning of colour pictures with P/sup 2/CCC-all solid state line sensors

    Damann, H; Rabe, G; Zinke, M; Herrmann, M; Imjela, R; Laasch, I; Mueller, J; Neumann, K; Tauchen, G; Woelber, J

    1982-04-01

    A new one-chip all solid state line sensor (P/sup 2/CCD-Tricoli) has been realized as a basis for the opto-electronic scanning of colour pictures. The three photosensitive lines for the colour components red, green and blue contain each 652 photo elements. They are arranged in parallel on one silicon crystal, with distances of some 100 ..mu..m. The line sensor is supplied with an extra designed driving circuitry and a signal processing. For colour splitting a colour separating digital phase grating has been developed which generates the three colour components in its three central diffraction orders. Using all the development components ('Tricoli'-line-sensor, electronic circuitry, colour separation grating) a model of a slide scanner has been built up, which succesfully demonstrates the feasibility of the proposed colour scanning system.

  11. SUPPORTING UAVS IN LOW VISIBILITY CONDITIONS BY MULTIPLE-PULSE LASER SCANNING DEVICES

    A. Djuricic

    2013-04-01

    Full Text Available Unmanned Aerial Vehicles (UAVs are nowadays promising platforms for capturing spatial information, because they are low cost solutions, which are easy to bring to the surveying field and can operate automatically. Usually these devices are equipped with visual sensors to support the navigation of the platform or to transmit observations of the environment to the operator. By collecting the data and processing the captured images even an estimation of the observed environment in form of 3D information is available. Therefore Simultaneous Localization and Mapping (SLAM algorithms are well known for processing data which is captured in the visible domain. However, situations can occur where gathering visual information is difficult due to given limitations in form of low visibility. For example if soft obstacles in form of translucent materials are given in disaster scenarios with smoke and operating has still to be ensured, active optical sensors (e.g. laser scanners are gaining interest because they can penetrate the soft obstacle and allow to acquire information behind it. A new lightweight (210 g, simplified and minimized scanning unit is now available which allows to capture multiple reflections for each transmitted laser pulse, namely the Hokuyo UTM-30LX-EW. With such a device, it is possible to overcome the above mentioned restrictions or limitations of low visibility by soft obstacles and even measure under critical circumstances. A multi-pulse system can provide accurate measurements on, within, and behind the soft obstacle. This research focuses on investigating the ability and performance of a laser scanner to penetrate the soft obstacle. Thus, investigations on a system that overcomes these limitations and provides a solution will be given. First promising experimental results considering soft obstacle are described.

  12. Underwater 3D Surface Measurement Using Fringe Projection Based Scanning Devices.

    Bräuer-Burchardt, Christian; Heinze, Matthias; Schmidt, Ingo; Kühmstedt, Peter; Notni, Gunther

    2015-12-23

    In this work we show the principle of optical 3D surface measurements based on the fringe projection technique for underwater applications. The challenges of underwater use of this technique are shown and discussed in comparison with the classical application. We describe an extended camera model which takes refraction effects into account as well as a proposal of an effective, low-effort calibration procedure for underwater optical stereo scanners. This calibration technique combines a classical air calibration based on the pinhole model with ray-based modeling and requires only a few underwater recordings of an object of known length and a planar surface. We demonstrate a new underwater 3D scanning device based on the fringe projection technique. It has a weight of about 10 kg and the maximal water depth for application of the scanner is 40 m. It covers an underwater measurement volume of 250 mm × 200 mm × 120 mm. The surface of the measurement objects is captured with a lateral resolution of 150 μm in a third of a second. Calibration evaluation results are presented and examples of first underwater measurements are given.

  13. Line-scanning confocal microscopy for high-resolution imaging of upconverting rare-earth-based contrast agents

    Higgins, Laura M.; Zevon, Margot; Ganapathy, Vidya; Sheng, Yang; Tan, Mei Chee; Riman, Richard E.; Roth, Charles M.; Moghe, Prabhas V.; Pierce, Mark C.

    2015-01-01

    Abstract. Rare-earth (RE) doped nanocomposites emit visible luminescence when illuminated with continuous wave near-infrared light, making them appealing candidates for use as contrast agents in biomedical imaging. However, the emission lifetime of these materials is much longer than the pixel dwell times used in scanning intravital microscopy. To overcome this limitation, we have developed a line-scanning confocal microscope for high-resolution, optically sectioned imaging of samples labeled with RE-based nanomaterials. Instrument performance is quantified using calibrated test objects. NaYF4:Er,Yb nanocomposites are imaged in vitro, and in ex vivo tissue specimens, with direct comparison to point-scanning confocal microscopy. We demonstrate that the extended pixel dwell time of line-scanning confocal microscopy enables subcellular-level imaging of these nanomaterials while maintaining optical sectioning. The line-scanning approach thus enables microscopic imaging of this emerging class of contrast agents for preclinical studies, with the potential to be adapted for real-time in vivo imaging in the clinic. PMID:26603495

  14. Point Cloud Analysis for Uav-Borne Laser Scanning with Horizontally and Vertically Oriented Line Scanners - Concept and First Results

    Weinmann, M.; Müller, M. S.; Hillemann, M.; Reydel, N.; Hinz, S.; Jutzi, B.

    2017-08-01

    In this paper, we focus on UAV-borne laser scanning with the objective of densely sampling object surfaces in the local surrounding of the UAV. In this regard, using a line scanner which scans along the vertical direction and perpendicular to the flight direction results in a point cloud with low point density if the UAV moves fast. Using a line scanner which scans along the horizontal direction only delivers data corresponding to the altitude of the UAV and thus a low scene coverage. For these reasons, we present a concept and a system for UAV-borne laser scanning using multiple line scanners. Our system consists of a quadcopter equipped with horizontally and vertically oriented line scanners. We demonstrate the capabilities of our system by presenting first results obtained for a flight within an outdoor scene. Thereby, we use a downsampling of the original point cloud and different neighborhood types to extract fundamental geometric features which in turn can be used for scene interpretation with respect to linear, planar or volumetric structures.

  15. Device for welding a connection line to an electrode of a solar cell

    Lorans, D.Y.

    1976-08-05

    A method with associated device for welding connection lines to the electrodes of solar cells is described. To improve the weldability of the contacts usually consisting of silver, a weld-receiving device is vibrated with respect to the welding electrode, whereby disturbing surface layers are destroyed with a certain application pressure of the welding electrode. The method shows better results than, for example, a previous chemical cleaning of the contacts and is also more easy to handle.

  16. B-lines with Lung Ultrasound: The Optimal Scan Technique at Rest and During Stress.

    Scali, Maria Chiara; Zagatina, Angela; Simova, Iana; Zhuravskaya, Nadezhda; Ciampi, Quirino; Paterni, Marco; Marzilli, Mario; Carpeggiani, Clara; Picano, Eugenio

    2017-11-01

    Various lung ultrasound (LUS) scanning modalities have been proposed for the detection of B-lines, also referred to as ultrasound lung comets, which are an important indication of extravascular lung water at rest and after exercise stress echo (ESE). The aim of our study was to assess the lung water spatial distribution (comet map) at rest and after ESE. We performed LUS at rest and immediately after semi-supine ESE in 135 patients (45 women, 90 men; age 62 ± 12 y, resting left ventricular ejection fraction = 41 ± 13%) with known or suspected heart failure or coronary artery disease. B-lines were measured by scanning 28 intercostal spaces (ISs) on the antero-lateral chest, 2nd-5th IS, along with the midaxillary (MA), anterior axillary (AA), mid-clavicular (MC) and parasternal (PS) lines. Complete 28-region, 16-region (3rd and 4th IS), 8-region (3rd IS), 4-region (3rd IS, only AA and MA) and 1-region (left 3rd IS, MA) scans were analyzed. In each space, the B-lines were counted from 0 = black lung to 10 = white lung. Interpretable images were obtained in all spaces (feasibility = 100 %). B-lines (>0 in at least 1 space) were present at ESE in 93 patients (69%) and absent in 42. More B-lines were found in the 3rd IS and along AA and MA lines. The B-line cumulative distribution was symmetric at rest (right/left = 1.10) and asymmetric with left lung predominance during stress (right/left = 0.67). The correlation of per-patient B-line number between 28-S and 16-S (R 2  = 0.9478), 8-S (R 2  = 0.9478) and 4-S scan (R 2  = 0.9146) was excellent, but only good with 1-S (R 2  = 0.8101). The average imaging and online analysis time were 5 s per space. In conclusion, during ESE, the comet map of lung water accumulation follows a predictable spatial pattern with wet spots preferentially aligned with the third IS and along the AA and MA lines. The time-saving 4-region scan is especially convenient during stress, simply dismissing dry regions and

  17. Device intended for measurement of induced trapped charge in insulating materials under electron irradiation in a scanning electron microscope

    Belkorissat, R; Benramdane, N; Jbara, O; Rondot, S; Hadjadj, A; Belhaj, M

    2013-01-01

    A device for simultaneously measuring two currents (i.e. leakage and displacement currents) induced in insulating materials under electron irradiation has been built. The device, suitably mounted on the sample holder of a scanning electron microscope (SEM), allows a wider investigation of charging and discharging phenomena that take place in any type of insulator during its electron irradiation and to determine accurately the corresponding time constants. The measurement of displacement current is based on the principle of the image charge due to the electrostatic influence phenomena. We are reporting the basic concept and test results of the device that we have built using, among others, the finite element method for its calibration. This last method takes into account the specimen chamber geometry, the geometry of the device and the physical properties of the sample. In order to show the possibilities of the designed device, various applications under different experimental conditions are explored. (paper)

  18. Insertion device and beam line plans for the Advanced Photon Source: A report and recommendations by the Insertion Device and Beam Line Planning Committee

    1988-02-01

    In the 7-GeV Advanced Photon Source (APS) Conceptual Design Report (CDR), fifteen complete experimental beam lines were specified in order to establish a representative technical and cost base for the components involved. In order to optimize the composition of the insertion devices and the beam line, these funds are considered a ''Trust Fund.'' The present report evaluates the optimization for the distribution of these funds so that the short- and long-term research programs will be most productive, making the facility more attractive from the user's point of view. It is recommended that part of the ''Trust Fund'' be used for the construction of the insertion devices, the front-end components, and the first-optics, minimizing the cost to potential users of completing a beam line. In addition, the possibility of cost savings resulting from replication and standardization of high multiplicity components (such as IDs, front ends, and first-optics instrumentation) is addressed. 2 refs., 5 tabs

  19. Non-invasive and high-sensitivity scanning detection of magnetic nanoparticles in animals using high-Tc scanning superconducting-quantum-interference-device biosusceptometry.

    Chieh, J J; Hong, C Y

    2011-08-01

    Although magnetic nanoparticles (MNPs) have been widely applied to animals in biomedicine, MNPs within animals should be examined in real time, in vivo, and without bio-damaged possibility to evaluate whether the bio-function of MNPs is valid or to further controls the biomedicinal process because of accompanying complex problems such as MNPs distribution and MNPs biodegradation. The non-invasive and high-sensitivity scanning detection of MNPs in animals using ac susceptometry based on a high-T(c) superconducting quantum interference device (SQUID) is presented. The non-invasive results and biopsy results show good agreement, and two gold-standard biomedicine methods, Prussian blue stain and inductively coupled plasma, prove the magnetic results. This confirms that the future clinical diagnosis of bio-functional MNPs could be operated by using scanning SQUID biosusceptometry as conveniently as an ultrasonic probe.

  20. Analytical procedure for experimental quantification of carrier concentration in semiconductor devices by using electric scanning probe microscopy

    Fujita, Takaya; Matsumura, Koji; Itoh, Hiroshi; Fujita, Daisuke

    2014-01-01

    Scanning capacitance microscopy (SCM) is based on a contact-mode variant of atomic force microscopy, which is used for imaging two-dimensional carrier (electrons and holes) distributions in semiconductor devices. We introduced a method of quantification of the carrier concentration by experimentally deduced calibration curves, which were prepared for semiconductor materials such as silicon and silicon carbide. The analytical procedure was circulated to research organizations in a round-robin test. The effectiveness of the method was confirmed for practical analysis and for what is expected for industrial pre-standardization from the viewpoint of comparability among users. It was also applied to other electric scanning probe microscopy techniques such as scanning spreading resistance microscopy and scanning nonlinear dielectric microscopy. Their depth profiles of carrier concentration were found to be in good agreement with those characterized by SCM. These results suggest that our proposed method will be compatible with future next-generation microscopy. (paper)

  1. Near UV-visible line emission from tungsten highly-charged ions in Large Helical Device

    Kato, D.; Sakaue, H.A.; Murakami, I.; Goto, M.; Oishi, T.; Morita, S.; Fujii, K.; Nakamura, N.; Koike, F.; Sasaki, Akira; Ding, X.-B.; Dong, C.-Z.

    2015-01-01

    Wavelengths of emission lines from tungsten highly-charged ions have been precisely measured in near UV-visible range (320 - 356 nm and 382 - 402 nm) at Large Helical Device (LHD) by tungsten pellet injection. The tungsten emission lines were assigned based on its line-integrated intensity profiles on a poloidal cross section. The ground-term magnetic-dipole (M1) lines of W 26+,27+ and an M1 line of a metastable excited state of W 28+ , whose wavelengths have been determined by measurements using electron-beam-ion-traps (EBITs), are identified in the LHD spectra. The present results partially compliment wavelength data of tungsten highly-charged ions in the near UV-visible range. (author)

  2. The development of a line-scan imaging algorithm for the detection of fecal contamination on leafy geens

    Yang, Chun-Chieh; Kim, Moon S.; Chuang, Yung-Kun; Lee, Hoyoung

    2013-05-01

    This paper reports the development of a multispectral algorithm, using the line-scan hyperspectral imaging system, to detect fecal contamination on leafy greens. Fresh bovine feces were applied to the surfaces of washed loose baby spinach leaves. A hyperspectral line-scan imaging system was used to acquire hyperspectral fluorescence images of the contaminated leaves. Hyperspectral image analysis resulted in the selection of the 666 nm and 688 nm wavebands for a multispectral algorithm to rapidly detect feces on leafy greens, by use of the ratio of fluorescence intensities measured at those two wavebands (666 nm over 688 nm). The algorithm successfully distinguished most of the lowly diluted fecal spots (0.05 g feces/ml water and 0.025 g feces/ml water) and some of the highly diluted spots (0.0125 g feces/ml water and 0.00625 g feces/ml water) from the clean spinach leaves. The results showed the potential of the multispectral algorithm with line-scan imaging system for application to automated food processing lines for food safety inspection of leafy green vegetables.

  3. High Resolution Trichromatic Road Surface Scanning with a Line Scan Camera and Light Emitting Diode Lighting for Road-Kill Detection

    Gil Lopes

    2016-04-01

    Full Text Available This paper presents a road surface scanning system that operates with a trichromatic line scan camera with light emitting diode (LED lighting achieving road surface resolution under a millimeter. It was part of a project named Roadkills—Intelligent systems for surveying mortality of amphibians in Portuguese roads, sponsored by the Portuguese Science and Technology Foundation. A trailer was developed in order to accommodate the complete system with standalone power generation, computer image capture and recording, controlled lighting to operate day or night without disturbance, incremental encoder with 5000 pulses per revolution attached to one of the trailer wheels, under a meter Global Positioning System (GPS localization, easy to utilize with any vehicle with a trailer towing system and focused on a complete low cost solution. The paper describes the system architecture of the developed prototype, its calibration procedure, the performed experimentation and some obtained results, along with a discussion and comparison with existing systems. Sustained operating trailer speeds of up to 30 km/h are achievable without loss of quality at 4096 pixels’ image width (1 m width of road surface with 250 µm/pixel resolution. Higher scanning speeds can be achieved by lowering the image resolution (120 km/h with 1 mm/pixel. Computer vision algorithms are under development to operate on the captured images in order to automatically detect road-kills of amphibians.

  4. High Resolution Trichromatic Road Surface Scanning with a Line Scan Camera and Light Emitting Diode Lighting for Road-Kill Detection.

    Lopes, Gil; Ribeiro, A Fernando; Sillero, Neftalí; Gonçalves-Seco, Luís; Silva, Cristiano; Franch, Marc; Trigueiros, Paulo

    2016-04-19

    This paper presents a road surface scanning system that operates with a trichromatic line scan camera with light emitting diode (LED) lighting achieving road surface resolution under a millimeter. It was part of a project named Roadkills-Intelligent systems for surveying mortality of amphibians in Portuguese roads, sponsored by the Portuguese Science and Technology Foundation. A trailer was developed in order to accommodate the complete system with standalone power generation, computer image capture and recording, controlled lighting to operate day or night without disturbance, incremental encoder with 5000 pulses per revolution attached to one of the trailer wheels, under a meter Global Positioning System (GPS) localization, easy to utilize with any vehicle with a trailer towing system and focused on a complete low cost solution. The paper describes the system architecture of the developed prototype, its calibration procedure, the performed experimentation and some obtained results, along with a discussion and comparison with existing systems. Sustained operating trailer speeds of up to 30 km/h are achievable without loss of quality at 4096 pixels' image width (1 m width of road surface) with 250 µm/pixel resolution. Higher scanning speeds can be achieved by lowering the image resolution (120 km/h with 1 mm/pixel). Computer vision algorithms are under development to operate on the captured images in order to automatically detect road-kills of amphibians.

  5. The sinusoidal lining cells in "normal" human liver. A scanning electron microscopic investigation

    Horn, T; Henriksen, Jens Henrik Sahl; Christoffersen, P

    1986-01-01

    The scanning electron microscopic was used to study the fenestrations of human liver sinusoids. Thirteen biopsies, where light microscopy and transmission electron microscopy revealed normal sinusoidal architecture, were investigated. The number of fenestrae was calculated in acinar zone 3...

  6. Indium-oxide nanoparticles for RRAM devices compatible with CMOS back-end-off-line

    León Pérez, Edgar A. A.; Guenery, Pierre-Vincent; Abouzaid, Oumaïma; Ayadi, Khaled; Brottet, Solène; Moeyaert, Jérémy; Labau, Sébastien; Baron, Thierry; Blanchard, Nicholas; Baboux, Nicolas; Militaru, Liviu; Souifi, Abdelkader

    2018-05-01

    We report on the fabrication and characterization of Resistive Random Access Memory (RRAM) devices based on nanoparticles in MIM structures. Our approach is based on the use of indium oxide (In2O3) nanoparticles embedded in a dielectric matrix using CMOS-full-compatible fabrication processes in view of back-end-off-line integration for non-volatile memory (NVM) applications. A bipolar switching behavior has been observed using current-voltage measurements (I-V) for all devices. Very high ION/IOFF ratios have been obtained up to 108. Our results provide insights for further integration of In2O3 nanoparticles-based devices for NVM applications. He is currently a Postdoctoral Researcher in the Institute of Nanotechnologies of Lyon (INL), INSA de Lyon, France, in the Electronics Department. His current research include indium oxide nanoparticles for non-volatile memory applications, and the integrations of these devices in CMOS BEOL.

  7. 75 FR 70290 - In the Matter of Certain Biometric Scanning Devices, Components Thereof, Associated Software, and...

    2010-11-17

    ... INTERNATIONAL TRADE COMMISSION [Inv. No. 337-TA-720] In the Matter of Certain Biometric Scanning... Tariff Act of 1930, 19 U.S.C. 1337, based on a complaint filed by Cross Match Technologies, Inc. of Palm... for importation, and sale within the United States after importation of certain biometric scanning...

  8. ELABORATION OF THE 3D MODEL AND SURVEY OF THE POWER LINES USING DATA FROM AIRBORNE LASER SCANNING

    Bogusława Kwoczyńska

    2016-09-01

    Full Text Available One of the methods of obtaining highly accurate and current spatial data about the terrain, as well as objects situated on it, is laser scanning. LIDAR (Light Detection and Ranging is among the most modern, dynamically developing technologies and reveals in surveying new capabilities that have been unachievable in a traditional way so far. The aim of the publication is to show the possibilities of using data from airborne laser scanning to perform the survey and visualization of the energy network, and also identification of hazards which the present network constitutes for the immediate environment using the TerraSolid software package. The survey was conducted for two independent sections of the power line, on the basis of two different clouds of points obtained from the airborne laser scanning. The first one had a density of 16 points/m2, while the other 22 pts/m2. The project was created in an environment of MicroStation V8i software using special overlays – TerraScan and TerraModeler of Finnish TerraSolid Company. The use of the test clouds of different densities was intended to indicate an optimal density of the cloud of points, which allows carrying out a survey and visualization of the energy network based on data derived from airborne laser scanning. The publication presents on particular examples the procedure of vectorization and visualization of the power line and detection of objects within a dangerous distance from it. The possibility of using applied LIDAR data, meeting the industry requirements, to the survey of power lines has been also confirmed.

  9. Conceptual design and development of a superconducting bus-line for the Large Helical Device

    Mito, T.; Takahata, K.; Yamada, S.; Yamamoto, J.; Uede, T.; Ikeda, M.

    1993-01-01

    A superconducting bus-line is proposed and preliminarily tested as an electrical feeder between the superconducting coils of the Large Helical Device (LHD) and their electrical power supply. The bus-line consists of a superconductor and its cryogenic transfer-line. The superconductor is a specially developed aluminum stabilized NbTi wire, which is installed in the innermost channel of the transfer-line. The vacuum insulated transfer-line consists of four corrugated tubes assembled coaxially. Liquid helium flows through the innermost channel and shield gas flows through another annular channel in the line. We are completing the conceptual design of the bus-line and the installation plan for the LHD experimental hall and are carrying out development of wires, including an investigation of their mechanical properties and electrical insulation. This report describes the conceptual design of the superconducting bus-line for the LHD, and the results we obtained recently during the design and development of a full-scale demonstration facility. (orig.)

  10. High-resolution imaging of magnetic fields using scanning superconducting quantum interference device (SQUID) microscopy

    Fong de Los Santos, Luis E.

    Development of a scanning superconducting quantum interference device (SQUID) microscope system with interchangeable sensor configurations for imaging magnetic fields of room-temperature (RT) samples with sub-millimeter resolution. The low-critical-temperature (Tc) niobium-based monolithic SQUID sensor is mounted in the tip of a sapphire rod and thermally anchored to the cryostat helium reservoir. A 25 mum sapphire window separates the vacuum space from the RT sample. A positioning mechanism allows adjusting the sample-to-sensor spacing from the top of the Dewar. I have achieved a sensor-to-sample spacing of 100 mum, which could be maintained for periods of up to 4 weeks. Different SQUID sensor configurations are necessary to achieve the best combination of spatial resolution and field sensitivity for a given magnetic source. For imaging thin sections of geological samples, I used a custom-designed monolithic low-Tc niobium bare SQUID sensor, with an effective diameter of 80 mum, and achieved a field sensitivity of 1.5 pT/Hz1/2 and a magnetic moment sensitivity of 5.4 x 10-18 Am2/Hz1/2 at a sensor-to-sample spacing of 100 mum in the white noise region for frequencies above 100 Hz. Imaging action currents in cardiac tissue requires higher field sensitivity, which can only be achieved by compromising spatial resolution. I developed a monolithic low-Tc niobium multiloop SQUID sensor, with sensor sizes ranging from 250 mum to 1 mm, and achieved sensitivities of 480 - 180 fT/Hz1/2 in the white noise region for frequencies above 100 Hz, respectively. For all sensor configurations, the spatial resolution was comparable to the effective diameter and limited by the sensor-to-sample spacing. Spatial registration allowed us to compare high-resolution images of magnetic fields associated with action currents and optical recordings of transmembrane potentials to study the bidomain nature of cardiac tissue or to match petrography to magnetic field maps in thin sections of

  11. IDENTIFIKASI PROFIL DASAR LAUT MENGGUNAKAN INSTRUMEN SIDE SCAN SONAR DENGAN METODE BEAM PATTERN DISCRETE-EQUI-SPACED UNSHADED LINE ARRAY

    Muhammad Zainuddin Lubis

    2017-05-01

    Full Text Available Laut Punggur merupakan laut yang terletak di Batam, Kepulauan Riau yang mempunyai beragam habitat objek,dan bentuk struktur bawah laut yang memiliki dinamika laut yang sangat tinggi. Side scan sonar (SSS merupakan instrumen pengembangan sistem sonar yang mampu menunjukkan dalam gambar dua dimensional permukaan dasar laut dengan kondisi kontur, topografi, dan target secara bersamaan. Metode Beam Pattern Discrete-Equi-Spaced Unshaded Line Array digunakan untuk menghitung beam pattern dua dimensi yang tergantung pada sudut dari gelombang suara yang masuk dari sumbu array yang diterima tergantung pada sudut di mana sinar suara pada array. Penelitian ini dilakukan pada Desember 2016 di laut Punggur,Batam, Kepulauan Riau-Indonesia, dengan koordinat 104 ° 08,7102 E dan 1° 03,2448 N sampai 1 ° 03.3977 N dan 104 ° 08,8133 E, menggunakan instrumen Side Scan Sonar C-Max CM2 Tow fish dengan frekuensi 325 kHz. Hasil yang diperoleh dari perekaman terdapat 7 target, dan Beam pattern dari metode Beam Discrete-Equi-Spaced Unshaded Line Array target 4 memiliki nilai tertinggi pada directivity Pattern yaitu 21.08 dB. Hasil model beam pattern ini memiliki nilai pusat pada incidence angle (o terhadap Directivity pattern (dB tidak berada di nilai 0 ataupun pada pusat beam pattern yang dihasilkan pada target 6 dengan nilai incident angle -1.5 o dan 1.5o mengalami penurunan hingga -40 dB. Karakteristik sedimen dasar perairan di laut punggur ditemukan lebih banyak pasir. Hasil metode Beam Discrete-Equi-Spaced Unshaded Line Array ditemukan bangkai kapal tenggelam.Kata Kunci: Side Scan Sonar, Beam Pattern Discrete-Equi-Spaced Unshaded Line Array, Incidence angle, Directivity pattern IDENTIFICATION OF SEABED PROFILE USING SIDE SCAN SONAR INSTRUMENT WITH PATTERN DISCRETE-EQUI-SPACED UNSHADED LINE ARRAY METHODRiau Islands is an island that has a variety of habitat objects, and forms of submarine structures that have a very high ocean dynamics, Punggur Sea is the sea

  12. An electronic probe micro-analyser. A linear scan device; Microanalyseur a sonde electronique. Dispositif de balayage lineaire

    Kirianenko, A; Maurice, F [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1963-07-01

    The Castaing electronic probe micro-analyser makes possible static analysis at successive points. For two years this apparatus has been equipped by its constructor with an automatic device for surface scanning. In order to increase the micro-analyser's efficiency a 'linear' scan device has been incorporated making it possible to obtain semi-quantitative analyses very rapidly. (authors) [French] Le microanalyseur a sonde electronique de Castaing permet l'analyse statique en des points successifs. Depuis deux ans, cet appareil a ete equipe par son constructeur d'un dispositif de balayage automatique 'surface'. Afin d'augmenter l'efficacite du microanalyaeur, on a adapte un dispositif de balayage 'lineaire' qui permet d'obtenir tres rapidement des analyses semi-quantitative. (auteurs)

  13. Experimental design and methodology for a new Moessbauer scan experiment: absorption line tracking

    Veiga, A.; Pasquevich, G. A.; Zelis, P. Mendoza; Sanchez, F. H.; Fernandez van Raap, M. B.; Martinez, N.

    2009-01-01

    A new experimental setup and methodology that allows the automatic tracking of a Moessbauer absorption line as its energy position varies during the experiment is introduced. As a test the sixth spectral line of FeSn 2 was tracked while temperature was varied between room temperature and a value slightly above its Neel temperature.

  14. ConoSurf: Open-source 3D scanning system based on a conoscopic holography device for acquiring surgical surfaces.

    Brudfors, Mikael; García-Vázquez, Verónica; Sesé-Lucio, Begoña; Marinetto, Eugenio; Desco, Manuel; Pascau, Javier

    2017-09-01

    A difficulty in computer-assisted interventions is acquiring the patient's anatomy intraoperatively. Standard modalities have several limitations: low image quality (ultrasound), radiation exposure (computed tomography) or high costs (magnetic resonance imaging). An alternative approach uses a tracked pointer; however, the pointer causes tissue deformation and requires sterilizing. Recent proposals, utilizing a tracked conoscopic holography device, have shown promising results without the previously mentioned drawbacks. We have developed an open-source software system that enables real-time surface scanning using a conoscopic holography device and a wide variety of tracking systems, integrated into pre-existing and well-supported software solutions. The mean target registration error of point measurements was 1.46 mm. For a quick guidance scan, surface reconstruction improved the surface registration error compared with point-set registration. We have presented a system enabling real-time surface scanning using a tracked conoscopic holography device. Results show that it can be useful for acquiring the patient's anatomy during surgery. © 2016 The Authors. The International Journal of Medical Robotics and Computer Assisted Surgery Published by John Wiley & Sons Ltd.

  15. Numerical study of whisker field lines in the periphery of the Large Helical Device

    Akao, Hideki

    1990-01-01

    The behavior of periphery magnetic field lines in the standard Large-Helical Device (l=2 heliotron/torsatron type) configuration is studied numerically. Three different types of behavior are found, corresponding to three different regions: the stochastic region near the outermost magnetic surface, the whisker region, and the inter-whisker region outside the stochastic region. The behavior of whisker and inter-whisker field lines is specifically analyzed. It is found that whisker field lines exhibit both regular and irregular types of behavior, whereas inter-whisker field lines exhibit only regular behavior. The connection lengths for the whisker field lines are usually as long as several tens of toroidal pitches, whereas those for the inter-whisker field lines are usually less than ten toroidal pitch lengths. Whisker field lines are characterized by three fundamental processes; stretching, folding, and nesting associated with the motion of a residual X-point of the separatrix. Simple modeling is performed to reproduce these three fundamental processes. (author)

  16. SU-E-T-510: Interplay Between Spots Sizes, Spot / Line Spacing and Motion in Spot Scanning Proton Therapy

    Lee, TK

    2015-01-01

    Purpose In proton beam configuration for spot scanning proton therapy (SSPT), one can define the spacing between spots and lines of scanning as a ratio of given spot size. If the spacing increases, the number of spots decreases which can potentially decrease scan time, and so can whole treatment time, and vice versa. However, if the spacing is too large, the uniformity of scanned field decreases. Also, the field uniformity can be affected by motion during SSPT beam delivery. In the present study, the interplay between spot/ line spacing and motion is investigated. Methods We used four Gaussian-shape spot sizes with 0.5cm, 1.0cm, 1.5cm, and 2.0cm FWHM, three spot/line spacing that creates uniform field profile which are 1/3*FWHM, σ/3*FWHM and 2/3*FWHM, and three random motion amplitudes within, +/−0.3mm, +/−0.5mm, and +/−1.0mm. We planned with 2Gy uniform single layer of 10×10cm2 and 20×20cm2 fields. Then, mean dose within 80% area of given field size, contrubuting MU per each spot assuming 1cGy/MU calibration for all spot sizes, number of spots and uniformity were calculated. Results The plans with spot/line spacing equal to or smaller than 2/3*FWHM without motion create ∼100% uniformity. However, it was found that the uniformity decreases with increased spacing, and it is more pronounced with smaller spot sizes, but is not affected by scanned field sizes. Conclusion It was found that the motion during proton beam delivery can alter the dose uniformity and the amount of alteration changes with spot size which changes with energy and spot/line spacing. Currently, robust evaluation in TPS (e.g. Eclipse system) performs range uncertainty evaluation using isocenter shift and CT calibration error. Based on presented study, it is recommended to add interplay effect evaluation to robust evaluation process. For future study, the additional interplay between the energy layers and motion is expected to present volumetric effect

  17. Can anterior junction line be used to distinguish right middle from right upper lobe on CT scan?

    Cha, Jae Heon; Suh, Ja Young; Jo, Jin Man; Jeong, Hyeon Jo; Cheon, Mal Soon; Lee, Chul Woo; Yoon, Soon Min

    1997-01-01

    To evalvate the usefulness on a CT chest scan, of the anterior junction line as an anatomical landmark to distinguish the right middle and the right upper lobe We found that the anterior junction line has a constant anatomical relationship with the right upper and middle lobe, and with this in mind, analysed connvcntional CT films of 86 patients with normal lung(group A) and 30 with architectural distortion(group B). On a series of slices, we compared the location of slice 1 with that of slice 2(slice 1:the slice which includes the lowest portion of the anterior junction line, slice 2:the initial slice, in which the right middle lobe occupies the whole of the lung anterior to the right major fissure). In group A(n=86), the right upper lobe, as seen in the anteromedial zone of slice 1, was present in 83 cases(96.5%). The right upper lobe on slice 1 was absent in two cases(2.3%) in which a minor fissure was almost completely abent. In group B(n=30), the right upper lobe on slice 1 was absent in 19 cases(63.3%). We suggest that on a CT chest scan, the anterior junction line can be used as an anatomical landmark in the differentiation of the right middle from the right upper lobe, and as an indicator of the presence of architectural distortion

  18. Development of on-line monitoring device to detect the presence/absence of sodium vapor

    Wolson, R.D.; McPheeters, C.C.; Kremesec, V.J.; Kolba, V.M.

    1983-03-01

    A process is being developed by the Sodium Waste Technology Program at ANL-W to remove metallic sodium from scrap and waste. The final step in the process is the removal of residual metallic sodium by evaporation at temperatures up to 482 0 C (900 0 F) and at pressures of about 10 - 2 torr (1.3 Pa). Efficient operation of this process requires that the operators have a method to indicate the completion of the evaporation. This end point would signify when the chamber and scrap and waste is free of metallic sodium. It was determined that a measure of the vacuum was not sufficiently sensitive, and a research effort was undertaken to select an on-line monitoring device. In this effort, three promising methods were reviewed. The use of quadrupole mass spectrometer was recommended and an on-line device was designed for use in a Sodium Process Demonstration (SPD) Plant

  19. Rapid age determination of oysters using LA-ICP-MS line scans of shell Mg/Ca ratios

    Gillikin, D. P.; Durham, S. R.; Goodwin, D. H.

    2016-02-01

    Magnesium to calcium (Mg/Ca) ratios exhibit a strong temperature dependence in foraminifera and corals, but not in bivalve mollusks. Various studies have reported Mg/Ca-temperature relationships with R2 values ranging from 0.3 to 0.8 and significantly different relationships for bivalves growing at different salinities. However, this poor temperature correlation does not render Mg/Ca data useless. A weak temperature dependence would allow time (seasons and years) to be determined along the growth axis of shells. This would provide information about age, growth rate and also allow other proxies to be aligned with time. Typically, oxygen isotopes (δ18O) are used to age shells without clear periodic growth lines, which is time consuming and expensive. Line scans using laser ablation systems can cover several centimeters of shell in a few minutes. We test this method on the resilifer of two oyster species (Crassostrea gigas and C. virginica) using a 193 nm Laser-Ablation-ICP-MS. Living oysters were collected from San Francisco Bay, North Carolina, South Carolina, and the Gulf of Mexico; fossil shells (Pleistocene) were also collected in South Carolina. Shells were sampled for δ18O values and Mg/Ca ratios. We use annual cycles in δ18O values to confidently determine age, then apply the Mg/Ca technique. Shells of both species exhibit annual cyclicity in Mg/Ca ratios using spot and line scan laser sampling, which matche the seasonal cyclicity determined using δ18O values. Results show a good correlation between ages determined using the different methods. We conclude that LA-ICP-MS line scans offer a rapid and inexpensive technique for determining age, growth rate, and timing of shell growth in oyster reslifers.

  20. Extrinsic Parameter Calibration for Line Scanning Cameras on Ground Vehicles with Navigation Systems Using a Calibration Pattern

    Alexander Wendel

    2017-10-01

    Full Text Available Line scanning cameras, which capture only a single line of pixels, have been increasingly used in ground based mobile or robotic platforms. In applications where it is advantageous to directly georeference the camera data to world coordinates, an accurate estimate of the camera’s 6D pose is required. This paper focuses on the common case where a mobile platform is equipped with a rigidly mounted line scanning camera, whose pose is unknown, and a navigation system providing vehicle body pose estimates. We propose a novel method that estimates the camera’s pose relative to the navigation system. The approach involves imaging and manually labelling a calibration pattern with distinctly identifiable points, triangulating these points from camera and navigation system data and reprojecting them in order to compute a likelihood, which is maximised to estimate the 6D camera pose. Additionally, a Markov Chain Monte Carlo (MCMC algorithm is used to estimate the uncertainty of the offset. Tested on two different platforms, the method was able to estimate the pose to within 0.06 m/1.05 ∘ and 0.18 m/2.39 ∘ . We also propose several approaches to displaying and interpreting the 6D results in a human readable way.

  1. Effect of post crosslinking haze on the repeatability of Scheimpflug-based and slit-scanning imaging devices

    Rohit Shetty

    2017-01-01

    Full Text Available Purpose: The aim of this study was to analyze the effect of postcollagen crosslinking (CXL haze on the measurement and repeatability of pachymetry and mean keratometry (Km of four corneal topographers. Materials and Methods: Sixty eyes of sixty patients with progressive keratoconus who had undergone accelerated CXL (ACXL underwent imaging with a scanning slit imaging device (Orbscan II and three Scheimpflug imaging devices (Pentacam HR, Sirius, and Galilei. Post-ACXL haze was measured using the densitometry software on the Pentacam HR. Readings of the thinnest corneal thickness (TCT and Km from three scans of each device were analyzed. Effect of haze on the repeatability of TCT and Km measurements was evaluated using regression models. Repeatability was assessed by coefficient of variation. Results: Corneal densitometry in different zones affected the repeatability of TCT measurement of Orbscan (P < 0.05 significantly but not the repeatability of TCT with Pentacam HR and Sirius (P = 0.03 and 0.05, respectively. Km values were affected by haze when measured with the Pentacam HR (P < 0.05. The repeatability of Km readings for all devices was unaffected by haze. In the anterior 0–2 mm and 2–6 mm zone, TCT (P = 0.43 and 0.45, respectively, Km values (P = 0.4 and 0.6, respectively, repeatability of TCT (P = 0.1 in both zones, and Km (P = 0.5 and 0.1, respectively with Galilei were found to be the most reliable. Conclusion: Galilei measurements appear to be least affected by post-ACXL haze when compared with other devices. Hence, topography measurements in the presence of haze need to be interpreted with caution.

  2. Transmission line pulse system for avalanche characterization of high power semiconductor devices

    Riccio, Michele; Ascione, Giovanni; De Falco, Giuseppe; Maresca, Luca; De Laurentis, Martina; Irace, Andrea; Breglio, Giovanni

    2013-05-01

    Because of the increasing in power density of electronic devices for medium and high power application, reliabilty of these devices is of great interest. Understanding the avalanche behaviour of a power device has become very important in these last years because it gives an indication of the maximum energy ratings which can be seen as an index of the device ruggedness. A good description of this behaviour is given by the static IV blocking characteristc. In order to avoid self heating, very relevant in high power devices, very short pulses of current have to be used, whose value can change from few milliamps up to tens of amps. The most used method to generate short pulses is the TLP (Transmission Line Pulse) test, which is based on charging the equivalent capacitance of a transmission line to high value of voltage and subsequently discharging it onto a load. This circuit let to obtain very short square pulses but it is mostly used for evaluate the ESD capability of semiconductor and, in this environment, it generates pulses of low amplitude which are not high enough to characterize the avalanche behaviour of high power devices . Advanced TLP circuit able to generate high current are usually very expensive and often suffer of distorption of the output pulse. In this article is proposed a simple, low cost circuit, based on a boosted-TLP configuration, which is capable to produce very square pulses of about one hundreds of nanosecond with amplitude up to some tens of amps. A prototype is implemented which can produce pulses up to 20A of amplitude with 200 ns of duration which can characterize power devices up to 1600V of breakdown voltage. Usage of microcontroller based logic make the circuit very flexible. Results of SPICE simulation are provided, together with experimental results. To prove the effectiveness of the circuit, the I-V blocking characteristics of two commercial devices, namely a 600V PowerMOS and a 1200V Trench-IGBT, are measured at different

  3. Determination of line edge roughness in low dose top-down scanning electron microscopy images

    Verduin, T.; Kruit, P.; Hagen, C. W.

    2014-04-01

    We investigated off-line metrology for LER determination in low-dose SEM images to reduce the acquisition time and the risk of shrinkage. Our first attempts are based on filtering noisy (experimental) SEM images and use peak detection to measure the edge displacements and calculating the discrete PSD. However, the result of the filtering is that the power spectrum of the filter leaks into the PSD. So it is better to avoid a filter at all. We subsequently developed a method to detect edge displacements without the use of a filter. This method considers the signal profile of a SEM by integrating an experimental image of lines in the direction of the edges. The signal profile of an isolated edge is modeled as two merged Gaussians. This signal profile is then fitted against the raw (unfiltered) data of the edge pattern using an interior trust-region-reflective minimization procedure. This gives the edge displacements without the use of a filter and a filter-free version of the discrete PSD is obtained. The determination of edge displacements without the use of a filter, enables us to study how much noise is acceptable and still determine LER. To answer this question we generate random lines using the model of Palasantzas and the algorithm of Thorsos. This gives random generated edge displacements for typical values of experimental lines for the parameters of the model: 2 μm long lines (256 pixels), a correlation length ξ of 25 nm and a roughness exponent of 0.75. A noise-free top-down SEM-like image of lines is created by shifting the profile signal according to the random generated edge displacements. The image is further processed by adding Poisson-distributed noise. We consider three noise cases where the average electron density is about 2, 20 and 200 electrons per pixel. This corresponds to a charge density of (in respective order) 10 μC/cm2, 100 μC/cm2 and 1000 μC/cm2. The edge displacements of the random generated images are determined using our new

  4. [Accuracy of attenuation coefficient obtained by 137Cs single-transmission scanning in PET: comparison with conventional germanium line source].

    Matsumoto, Keiichi; Kitamura, Keishi; Mizuta, Tetsuro; Shimizu, Keiji; Murase, Kenya; Senda, Michio

    2006-02-20

    Transmission scanning can be successfully performed with a Cs-137 single-photon-emitting point source for three-dimensional PET imaging. This method was effective for postinjection transmission scanning because of differences in physical energy. However, scatter contamination in the transmission data lowers measured attenuation coefficients. The purpose of this study was to investigate the accuracy of the influence of object scattering by measuring the attenuation coefficients on the transmission images. We also compared the results with the conventional germanium line source method. Two different types of PET scanner, the SET-3000 G/X (Shimadzu Corp.) and ECAT EXACT HR(+) (Siemens/CTI) , were used. For the transmission scanning, the SET-3000 G/X and ECAT HR(+) were the Cs-137 point source and Ge-68/Ga-68 line source, respectively. With the SET-3000 G/X, we performed transmission measurement at two energy gate settings, the standard 600-800 keV as well as 500-800 keV. The energy gate setting of the ECAT HR(+) was 350-650 keV. The effects of scattering in a uniform phantom with different cross-sectional areas ranging from 201 cm(2) to 314 cm(2) to 628 cm(2) (apposition of the two 20 cm diameter phantoms) and 943 cm(2) (stacking of the three 20 cm diameter phantoms) were acquired without emission activity. First, we evaluated the attenuation coefficients of the two different types of transmission scanning using region of interest (ROI) analysis. In addition, we evaluated the attenuation coefficients with and without segmentation for Cs-137 transmission images using the same analysis. The segmentation method was a histogram-based soft-tissue segmentation process that can also be applied to reconstructed transmission images. In the Cs-137 experiment, the maximum underestimation was 3% without segmentation, which was reduced to less than 1% with segmentation at the center of the largest phantom. In the Ge-68/Ga-68 experiment, the difference in mean attenuation

  5. Accuracy of attenuation coefficient obtained by 137Cs single-transmission scanning in PET. Comparison with conventional germanium line source

    Matsumoto, Keiichi; Shimizu, Keiji; Senda, Michio; Kitamura, Keishi; Mizuta, Tetsuro; Murase, Kenya

    2006-01-01

    Transmission scanning can be successfully performed with a Cs-137 single-photon-emitting point source for three-dimensional PET imaging. This method was effective for postinjection transmission scanning because of differences in physical energy. However, scatter contamination in the transmission data lowers measured attenuation coefficients. The purpose of this study was to investigate the accuracy of the influence of object scattering by measuring the attenuation coefficients on the transmission images. We also compared the results with the conventional germanium line source method. Two different types of PET scanner, the SET-3000 G/X (Shimadzu Corp.) and ECAT EXACT HR + (Siemens/CTI), were used. For the transmission scanning, the SET-3000 G/X and ECAT HR + were the Cs-137 point source and Ge-68/Ga-68 line source, respectively. With the SET-3000 G/X, we performed transmission measurement at two energy gate settings, the standard 600-800 keV as well as 500-800 keV. The energy gate setting of the ECAT HR 2 + was 350-650 keV. The effects of scattering in a uniform phantom with different cross-sectional areas ranging from 201 cm 2 to 314 cm 2 to 628 cm 2 (apposition of the two 20 cm diameter phantoms) and 943 cm 2 (stacking of the three 20 cm diameter phantoms) were acquired without emission activity. First, we evaluated the attenuation coefficients of the two different types of transmission scanning using region of interest (ROI) analysis. In addition, we evaluated the attenuation coefficients with and without segmentation for Cs-137 transmission images using the same analysis. The segmentation method was a histogram-based soft-tissue segmentation process that can also be applied to reconstructed transmission images. In the Cs-137 experiment, the maximum underestimation was 3% without segmentation, which was reduced to less than 1% with segmentation at the center of the largest phantom. In the Ge-68/Ga-68 experiment, the difference in mean attenuation coefficients

  6. Method for updating pipelined, single port Z-buffer by segments on a scan line

    Hannah, M.R.

    1990-01-01

    This patent describes, in a raster scan, computer controlled video display system for presenting an image to an observer. Having Z-buffer for storing Z values and a frame buffer for storing pixel values, a method for updating the Z-buffer with new Z values to replace old Z values. It comprises: calculating a new pixel value and a new Z value for each pixel location in pixel locations, performing a Z comparison for each new Z value by comparing the old Z value with the new Z value for each pixel location, the Z comparison being performed sequentially in one direction through the plurality of pixel locations, and updating the Z-buffer only after the Z comparison produces a combination of a fail condition for a current pixel location subsequent to producing a pass condition for a pixel location immediately preceding the current pixel location

  7. Line scan micro XRF analysis of engobe of whiteware painted with red, green and yellow patterns

    Yang Yimin; Wang Lihua; Zhu Jian; Wang Changsui; Yan Yan; Chen Dongliang; He Wei; Huang Yuying; Hua Wei; Xu Wei

    2008-01-01

    Whiteware painted with red, green and yellow patterns play an important role in China's development in glaze decoration. In this paper, cross-sections of the porcelain samples were scanned from glaze to body by synchrotron radiation and element contents of the samples were analyzed by SRXRF. The results revealed a transition between the glaze and engobe, and the engobe and body. In the transition area, elemental content changes were related to the raw material to form the glaze, engobe and body, and diffusing ability of the elements depended on thickness of the glaze and the elemental contents of each layer. The engobe had lower Fe and Ti concentrations than the body, hence improving the whiteness and quality of the porcelain. According to petrography, engobe was rich in mica minerals, leading to enhanced reflection effect of the white porcelain. This has not been reported before and further studies are underway. (authors)

  8. A neural network device for on-line particle identification in cosmic ray experiments

    Scrimaglio, R.; Finetti, N.; D'Altorio, L.; Rantucci, E.; Raso, M.; Segreto, E.; Tassoni, A.; Cardarilli, G.C.

    2004-01-01

    On-line particle identification is one of the main goals of many experiments in space both for rare event studies and for optimizing measurements along the orbital trajectory. Neural networks can be a useful tool for signal processing and real time data analysis in such experiments. In this document we report on the performances of a programmable neural device which was developed in VLSI analog/digital technology. Neurons and synapses were accomplished by making use of Operational Transconductance Amplifier (OTA) structures. In this paper we report on the results of measurements performed in order to verify the agreement of the characteristic curves of each elementary cell with simulations and on the device performances obtained by implementing simple neural structures on the VLSI chip. A feed-forward neural network (Multi-Layer Perceptron, MLP) was implemented on the VLSI chip and trained to identify particles by processing the signals of two-dimensional position-sensitive Si detectors. The radiation monitoring device consisted of three double-sided silicon strip detectors. From the analysis of a set of simulated data it was found that the MLP implemented on the neural device gave results comparable with those obtained with the standard method of analysis confirming that the implemented neural network could be employed for real time particle identification

  9. Development of on line automatic separation device for apple and sleeve

    Xin, Dengke; Ning, Duo; Wang, Kangle; Han, Yuhang

    2018-04-01

    Based on STM32F407 single chip microcomputer as control core, automatic separation device of fruit sleeve is designed. This design consists of hardware and software. In hardware, it includes mechanical tooth separator and three degree of freedom manipulator, as well as industrial control computer, image data acquisition card, end effector and other structures. The software system is based on Visual C++ development environment, to achieve localization and recognition of fruit sleeve with the technology of image processing and machine vision, drive manipulator of foam net sets of capture, transfer, the designated position task. Test shows: The automatic separation device of the fruit sleeve has the advantages of quick response speed and high separation success rate, and can realize separation of the apple and plastic foam sleeve, and lays the foundation for further studying and realizing the application of the enterprise production line.

  10. Program for large scanning-measuring table calibration on-line with the TRA-1001 computer

    Kalmykova, L.P.; Ososkov, G.A.; Pogodina, G.A.; Skryl', I.I.

    1975-01-01

    A description of a programme variant for complex calibration of the system of boards BPS-2, is given in which the stage of measurements and accumulation of calibration data is separated from that of data processing on CDC-1604A computers. Stage-by-stage calibration allows for simultaneous and parallel measurements on all the 6 boards. Such a possibility of the boards' operation on a computer-controlled line has been used as checking of the operators' actions with current control of the data obtained. Mathematical formulae are followed by programmes' descriptions. Reception and accumulation of coordinates of the units of the calibrating plate, with a highly precise net of straight lines, are accomplished with the help of the DATREC programme working on a guiding TPA-1001 computer with simultaneous calibration of all the six BPS-2 boards. The DATREC programme is written in the SLANG-1 language. The CALBPS programme works on CDC-1604A computer, is written in FORTRAN, and calculates transformation coefficients and corresponding precision characteristics. The work has resulted in reducing the calibration time from 10-15 min. per board to 10-15 min. per all the 6 boards. The time of accumulation in the memory TPA-1001 and of recording on the CDC-608 tape recorder of calibration data is from 3 to 5 min.; the remaining time is spent on processing on a bigger CDC-1604A computer. Examples of typical output and certain results of calibration measurements are given

  11. Focal hot spot induced by a central subclavian line on bone scan.

    Moslehi, Masood; Cheki, Mohsen; Dehghani, Tohid; Eftekhari, Mansoureh

    2014-01-01

    The diagnostic accuracy of nuclear medicine reporting can be improved by awareness of these instrument-related artifacts. Both awareness and experience are also important when it comes to detecting and identifying normal (and abnormal) variants. We present a case of hot spot on the upper right chest in the region of right subclavicular region resulting from injection of radiotracer from central subclavian line. A 52-year-old woman with a history of left breast cancer and recent bone pain was referred to our nuclear medicine department for skeletal survey. Anterior views of chest show a focus of increased radiotracer uptake corresponding to anterior arch of one of the right second rib. The nuclear physician reported it as a focal rib bony lesion and recommended radiological evaluation. As technician later explained, physicians realized that injection site was a central subclavian line on the right side and hot spot on that region is due to injection site. The appearance of both skeletal and soft-tissue uptake depends heavily on imaging technique (such as the route of radiotracer administration) and the interpreting physicians should be aware of the impact of technical factors on image quality.

  12. Spin-filter scanning tunneling microscopy : a novel technique for the analysis of spin polarization on magnetic surfaces and spintronic devices

    Vera Marun, I.J.

    2010-01-01

    This thesis deals with the development of a versatile technique to measure spin polarization with atomic resolution. A microscopy technique that can measure electronic spin polarization is relevant for characterization of magnetic nanostructures and spintronic devices. Scanning tunneling microscopy

  13. Test of the Capability of Laser Line Scan Technology to Support Benthic Habitat Mapping in Coral Reef Ecosystems, Maui Island, November 2006

    National Oceanic and Atmospheric Administration, Department of Commerce — The utility of Laser Line Scan (LLS) Technology for optical validation of benthic habitat map data from coral reef ecosystems was tested with a deployment of a...

  14. Micro-PIXE line-scan measurements of the yellow eel's otolith

    Zheng, Y. [Applied Ion Beam Physics Laboratory, Institute of Modern Physics, Fudan University, Shanghai 200433 (China); Guo, H.; Tang, W.; Wei, K. [Laboratory of Ichthyology, Shanghai Ocean University, Shanghai 201306 (China); Shen, H., E-mail: haoshen@fudan.edu.cn [Applied Ion Beam Physics Laboratory, Institute of Modern Physics, Fudan University, Shanghai 200433 (China); Yang, M.; Mi, Y. [Applied Ion Beam Physics Laboratory, Institute of Modern Physics, Fudan University, Shanghai 200433 (China)

    2011-10-15

    Anguilla japonica has a high economic value. The abundance had decreased significantly due to excessive fishing and change in the aquatic ecology. Life history patterns of A. japonica have been studied to prevent excessive fishing and make management plans. Strontium (Sr)-calcium (Ca) ratio along a line down the long axis from the core to the edge of the yellow eel's otolith was measured using micro proton induced X-ray emission (micro-PIXE). An efficient and precise method was proposed to locate the core where an otolith begins to grow, based on Sr concentration and distribution. Using this method, life history patterns of the yellow eels collected from Jingjiang River in China were investigated. In general, there are two types, river eels and estuarine eels.

  15. Micro-PIXE line-scan measurements of the yellow eel's otolith

    Zheng, Y.; Guo, H.; Tang, W.; Wei, K.; Shen, H.; Yang, M.; Mi, Y.

    2011-01-01

    Anguilla japonica has a high economic value. The abundance had decreased significantly due to excessive fishing and change in the aquatic ecology. Life history patterns of A. japonica have been studied to prevent excessive fishing and make management plans. Strontium (Sr)-calcium (Ca) ratio along a line down the long axis from the core to the edge of the yellow eel's otolith was measured using micro proton induced X-ray emission (micro-PIXE). An efficient and precise method was proposed to locate the core where an otolith begins to grow, based on Sr concentration and distribution. Using this method, life history patterns of the yellow eels collected from Jingjiang River in China were investigated. In general, there are two types, river eels and estuarine eels.

  16. Scanning capacitance microscopy of atomically-precise donor devices in Si

    Bussmann, Ezra; Rudolph, M.; Carr, S. M.; Subramania, G.; Ten Eyck, G.; Dominguez, J.; Lilly, M. P.; Carroll, M. S.; QIST Team

    2014-03-01

    Recently, a scanning tunneling microscopy (STM) technique to fabricate atomically-precise dopant-based nanoelectronics in Si has been developed. Phosphorus donors are placed via an atomic-precision template formed by STM H-depassivation lithography, then capped with epi-Si and lastly metal contacts are made to the buried donor layer using conventional microfabrication. New challenges are introduced with this approach that center around difficulties to locate and characterize the pattern of buried donors. In this talk, we show that scanning capacitance microscopy (SCM) can image these buried donor nanostructures with sub-100-nm tip-limited resolution. The technique is used to successfully locate and characterize buried donor nanostructures relative to surface alignment marks. This approach relaxes alignment requirements for the STM lithography step and can offer improved alignment of subsequent metallization steps. The SCM technique is also used to nondestructively image the shape of the electronic carrier distribution and characterize the relative doping levels. This work, performed in part at the Center for Integrated Nanotechnologies, a U.S. DOE Office of Basic Energy Sciences user facility, was supported by Sandia's Lab Directed Research and Development Program. Sandia is a multi-program lab operated by Sandia Corp, a Lockheed-Martin Company, for U. S. DOE under Contract DE-AC04-94AL85000.

  17. Lining up device for the internal structures of a nuclear reactor vessel

    Silverblatt, B.L.

    1977-01-01

    The invention concerns a nuclear reactor of the type with a vessel, a vessel head carried at the top of this vessel by a core cylinder comprising a flange internally supported by the vessel, and an upper support structure supported between the core cylinder flange and the vessel head to align laterally the head, vessel, flange and support structure. A bottom key device is provided for lining up the flange, support structure and vessel, and an upper key device for laterally lining up support structure and the vessel head and for maintaining this alignment when they are removed simultaneously from the core cylinder and vessel. When re-assembling the reactor, the top support structure and the vessel head are lowered simultaneously so that an opening in the top alignment structure engages in the upper extension of the bottom alignment structure. A plurality of alignment stuctures may be utilised round the circumference of the reactor vessel. The disposition of the invention also facilitates the removal of the core cylinder from the reactor vessel. In this way, the alignment on re-assembly is ensured by the re-entry of the bottom extension under the flange of the core cylinder with the groove or keyway of the reactor vessel [fr

  18. Element distribution imaging in rat kidney using a 2 D rapid scan EDXRF device

    Figueroa, R. G. [Universidad de la Frontera, Departamento de Ciencias Fisicas, Av. Francisco Salazar 1145, Temuco 4811230, Araucania (Chile); Lozano, E. [Instituto Nacional del Cancer, Unidad de Fisica Medica, Av. Profesor Zanartu 1010, Santiago (Chile); Bongiovanni, G., E-mail: figueror@ufro.cl [IDEPA-CONICET, Instituto Multidisciplinario de Investigacion y Desarrollo de la Patagonia Norte, Buenos Aires 1400, 8300 Neuquen (Argentina)

    2013-08-01

    Visualization of elemental distributions of biological tissue is gaining importance in many disciplines of biological, forensic and medical research. Furthermore, the maps of elements have wide application in archaeology for the understanding of the pigments, modes of preservation and environmental context. Since major advances in relation to collimators and detectors have yielded micro scale images, the chemical mapping via synchrotron scanning micro-X-ray fluorescence spectrometry (SR-{mu}X RF) is widely used as microanalytical techniques. However, the acquisition time is a limitation of current SR-{mu}X RF imaging protocols, doing tedious micro analysis of samples of more than 1 cm and very difficult to study of larger samples such as animal organ, whole organisms, work or art, etc. Recently we have developed a robotic system to image the chemistry of large specimens rapidly ar concentration levels of parts per million. Multiple images of distribution of elements can be obtained on surfaces of 100 x 100 mm and a spatial resolution of up to 0.2 mm{sup 2} per pixel, with a spectral capture time up to 1 ms per point. This system has proven to be highly efficient for the X RF mapping of elements in large biological samples, achieving comparable s results to those obtained by SR-{mu}X RF. Thus, images of As and Cu accumulation in renal cortex of arsenic-exposed rats were obtained by both methodologies. However, the new imaging system enables the X RF scanning in few minutes, whereas SR-{mu}X RF required several hours. These and other advantages as well as the potential applications of this system, will be discussed. (Author)

  19. Scanning-SQUID investigation of spin-orbit torque acting on yttrium iron garnet devices

    Rosenberg, Aaron J.; Jermain, Colin L.; Aradhya, Sriharsha V.; Brangham, Jack T.; Nowack, Katja C.; Kirtley, John R.; Yang, Fengyuan; Ralph, Daniel C.; Moler, Kathryn A.

    Successful manipulation of electrically insulating magnets, such as yttrium iron garnet, by by current-driven spin-orbit torques could provide a highly efficient platform for spintronic memory. Compared to devices fabricated using magnetic metals, magnetic insulators have the advantage of the ultra-low magnetic damping and the elimination of shunting currents in the magnet that reduce the torque efficiency. Here, we apply current in the spin Hall metal β-Ta to manipulate the magnetic orientation of micron-sized, electrically-insulating yttrium iron garnet devices. We do not observe spin-torque switching even for applied currents well above the critical current expected in a macrospin switching model. This suggests either inefficient transfer of spin torque at our Ta/YIG interface or a breakdown of the macrospin approximation. This work is supported by FAME, one of six centers of STARnet sponsored by MARCO and DARPA. The SQUID microscope and sensors were developed with support from the NSF-sponsored Center NSF-NSEC 0830228, and from NSF IMR-MIP 0957616.

  20. Multi-band Microwave Antennas and Devices based on Generalized Negative-Refractive-Index Transmission Lines

    Ryan, Colan Graeme Matthew

    Focused on the quad-band generalized negative-refractive-index transmission line (G-NRI-TL), this thesis presents a variety of novel printed G-NRI-TL multi-band microwave device and antenna prototypes. A dual-band coupled-line coupler, an all-pass G-NRI-TL bridged-T circuit, a dual-band metamaterial leaky-wave antenna, and a multi-band G-NRI-TL resonant antenna are all new developments resulting from this research. In addition, to continue the theme of multi-band components, negative-refractive-index transmission lines are used to create a dual-band circularly polarized transparent patch antenna and a two-element wideband decoupled meander antenna system. High coupling over two independently-specified frequency bands is the hallmark of the G-NRI-TL coupler: it is 0.35lambda0 long but achieves approximately -3 dB coupling over both bands with a maximum insertion loss of 1 dB. This represents greater design flexibility than conventional coupled-line couplers and less loss than subsequent G-NRI-TL couplers. The single-ended bridged-T G-NRI-TL offers a metamaterial unit cell with an all-pass magnitude response up to 8 GHz, while still preserving the quad-band phase response of the original circuit. It is shown how the all-pass response leads to wider bandwidths and improved matching in quad-band inverters, power dividers, and hybrid couplers. The dual-band metamaterial leaky-wave antenna presented here was the first to be reported in the literature, and it allows broadside radiation at both 2 GHz and 6 GHz without experiencing the broadside stopband common to conventional periodic antennas. Likewise, the G-NRI-TL resonant antenna is the first reported instance of such a device, achieving quad-band operation between 2.5 GHz and 5.6 GHz, with a minimum radiation efficiency of 80%. Negative-refractive-index transmission line loading is applied to two devices: an NRI-TL meander antenna achieves a measured 52% impedance bandwidth, while a square patch antenna incorporates

  1. Protection relay of phase-shifting device with thyristor switch for high voltage power transmission lines

    Lachugin, V. F.; Panfilov, D. I.; Akhmetov, I. M.; Astashev, M. G.; Shevelev, A. V.

    2014-12-01

    Problems of functioning of differential current protection systems of phase shifting devices (PSD) with mechanically changed coefficient of transformation of shunt transformer are analyzed. Requirements for devices of protection of PSD with thyristor switch are formulated. Based on use of nonlinear models of series-wound and shunt transformers of PSD modes of operation of major protection during PSD, switching to zero load operation and to operation under load and during short circuit operation were studied for testing PSD with failures. Use of the principle of duplicating by devices of differential current protection (with realization of functions of breaking) of failures of separate pares of PSD with thyristor switch was substantiated. To ensure protection sensitivity to the shunt transformer winding short circuit, in particular, to a short circuit that is not implemented in the current differential protection for PSD with mechanical switch, the differential current protection reacting to the amount of primary ampere-turns of high-voltage and low-voltage winding of this transformer was designed. Studies have shown that the use of differential current cutoff instead of overcurrent protection for the shunt transformer wndings allows one to provide the sensitivity during thyristor failure with the formation of a short circuit. The results of simulation mode for the PSD with switch thyristor designed to be installed as switching point of Voskhod-Tatarskaya-Barabinsk 220 kV transmission line point out the efficiency of the developed solutions that ensure reliable functioning of the PSD.

  2. On-Line Multi-Damage Scanning Spatial-Wavenumber Filter Based Imaging Method for Aircraft Composite Structure

    Yuanqiang Ren

    2017-05-01

    Full Text Available Structural health monitoring (SHM of aircraft composite structure is helpful to increase reliability and reduce maintenance costs. Due to the great effectiveness in distinguishing particular guided wave modes and identifying the propagation direction, the spatial-wavenumber filter technique has emerged as an interesting SHM topic. In this paper, a new scanning spatial-wavenumber filter (SSWF based imaging method for multiple damages is proposed to conduct on-line monitoring of aircraft composite structures. Firstly, an on-line multi-damage SSWF is established, including the fundamental principle of SSWF for multiple damages based on a linear piezoelectric (PZT sensor array, and a corresponding wavenumber-time imaging mechanism by using the multi-damage scattering signal. Secondly, through combining the on-line multi-damage SSWF and a PZT 2D cross-shaped array, an image-mapping method is proposed to conduct wavenumber synthesis and convert the two wavenumber-time images obtained by the PZT 2D cross-shaped array to an angle-distance image, from which the multiple damages can be directly recognized and located. In the experimental validation, both simulated multi-damage and real multi-damage introduced by repeated impacts are performed on a composite plate structure. The maximum localization error is less than 2 cm, which shows good performance of the multi-damage imaging method. Compared with the existing spatial-wavenumber filter based damage evaluation methods, the proposed method requires no more than the multi-damage scattering signal and can be performed without depending on any wavenumber modeling or measuring. Besides, this method locates multiple damages by imaging instead of the geometric method, which helps to improve the signal-to-noise ratio. Thus, it can be easily applied to on-line multi-damage monitoring of aircraft composite structures.

  3. Development and application of gamma scanning technology for on-line investigation of industrial process columns and vessels

    Jaafar Abdullah

    1999-01-01

    Plant Assessment Technology (PAT) group, in association with Intelligent System (IS) Group and Engineering Services Department of Malaysian Institute for Nuclear Technology Research (MINT) has developed gamma scanning facilities for on-line investigation of industrial process columns and vessels. The technology, based on the principle of gamma-ray absorption, has been successfully applied for troubleshooting of a number of distillation columns and process vessels in petroleum refineries, gas processing plants and chemical plants in the country and the region. This paper outlines basic characteristics of the system and describes the inspection procedures, and in addition, case studies are also presented. The case studies are purposely chosen to illustrate the versatility of the technology, and furthermore to demonstrate the economic benefits which can be realised from the application of this technology. (author)

  4. Fabrication of wear-resistant silicon microprobe tips for high-speed surface roughness scanning devices

    Wasisto, Hutomo Suryo; Yu, Feng; Doering, Lutz; Völlmeke, Stefan; Brand, Uwe; Bakin, Andrey; Waag, Andreas; Peiner, Erwin

    2015-05-01

    Silicon microprobe tips are fabricated and integrated with piezoresistive cantilever sensors for high-speed surface roughness scanning systems. The fabrication steps of the high-aspect-ratio silicon microprobe tips were started with photolithography and wet etching of potassium hydroxide (KOH) resulting in crystal-dependent micropyramids. Subsequently, thin conformal wear-resistant layer coating of aluminum oxide (Al2O3) was demonstrated on the backside of the piezoresistive cantilever free end using atomic layer deposition (ALD) method in a binary reaction sequence with a low thermal process and precursors of trimethyl aluminum and water. The deposited Al2O3 layer had a thickness of 14 nm. The captured atomic force microscopy (AFM) image exhibits a root mean square deviation of 0.65 nm confirming the deposited Al2O3 surface quality. Furthermore, vacuum-evaporated 30-nm/200-nm-thick Au/Cr layers were patterned by lift-off and served as an etch mask for Al2O3 wet etching and in ICP cryogenic dry etching. By using SF6/O2 plasma during inductively coupled plasma (ICP) cryogenic dry etching, micropillar tips were obtained. From the preliminary friction and wear data, the developed silicon cantilever sensor has been successfully used in 100 fast measurements of 5- mm-long standard artifact surface with a speed of 15 mm/s and forces of 60-100 μN. Moreover, the results yielded by the fabricated silicon cantilever sensor are in very good agreement with those of calibrated profilometer. These tactile sensors are targeted for use in high-aspect-ratio microform metrology.

  5. Modernization of a programmable scanning device used to develop remote inspection procedures related to the nondestructive examination of nuclear components

    Alencar, Donizete A.; Silva Junior, Silverio F.; Viana, Sadraque S.; Alves, Michel R.C.; Horta, Thamyris C.R.

    2011-01-01

    At CDTN's nondestructive test laboratory there is an electromechanical probe scanning device. That equipment is an important tool used in the development of procedures to be applied in remote inspections of nuclear equipment and components. In order to adequate its functionality an update was planned and executed. Keeping its excellent existing mechanical parts and DC motors, the original electronic power supply and the control unit was replaced by a new one. Furthermore, trajectory control and data processing algorithms were implemented by means of National Instruments LabVIEW 8.6 programming tool. So, both trajectory control and data acquisition/plotting systems were integrated as PC executable software. This paper presents details of the whole process, including the updated hardware, some screen shots showing the trajectory control program and a typical data presentation window. (author)

  6. Modernization of a programmable scanning device used to develop remote inspection procedures related to the nondestructive examination of nuclear components

    Alencar, Donizete A.; Silva Junior, Silverio F., E-mail: daa@cdtn.b, E-mail: silvasf@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Viana, Sadraque S.; Alves, Michel R.C.; Horta, Thamyris C.R. [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Dept. de Engenharia Eletronica

    2011-07-01

    At CDTN's nondestructive test laboratory there is an electromechanical probe scanning device. That equipment is an important tool used in the development of procedures to be applied in remote inspections of nuclear equipment and components. In order to adequate its functionality an update was planned and executed. Keeping its excellent existing mechanical parts and DC motors, the original electronic power supply and the control unit was replaced by a new one. Furthermore, trajectory control and data processing algorithms were implemented by means of National Instruments LabVIEW 8.6 programming tool. So, both trajectory control and data acquisition/plotting systems were integrated as PC executable software. This paper presents details of the whole process, including the updated hardware, some screen shots showing the trajectory control program and a typical data presentation window. (author)

  7. Scanning electron microscope measurement of width and shape of 10 nm patterned lines using a JMONSEL-modeled library

    Villarrubia, J.S., E-mail: john.villarrubia@nist.gov [Semiconductor and Dimensional Metrology Division, National Institute of Standards and Technology, Gaithersburg, MD 20899 (United States); Vladár, A.E.; Ming, B. [Semiconductor and Dimensional Metrology Division, National Institute of Standards and Technology, Gaithersburg, MD 20899 (United States); Kline, R.J.; Sunday, D.F. [Materials Science and Engineering Division, National Institute of Standards and Technology, Gaithersburg, MD 20899 (United States); Chawla, J.S.; List, S. [Intel Corporation, RA3-252, 5200 NE Elam Young Pkwy, Hillsboro, OR 97124 (United States)

    2015-07-15

    The width and shape of 10 nm to 12 nm wide lithographically patterned SiO{sub 2} lines were measured in the scanning electron microscope by fitting the measured intensity vs. position to a physics-based model in which the lines' widths and shapes are parameters. The approximately 32 nm pitch sample was patterned at Intel using a state-of-the-art pitch quartering process. Their narrow widths and asymmetrical shapes are representative of near-future generation transistor gates. These pose a challenge: the narrowness because electrons landing near one edge may scatter out of the other, so that the intensity profile at each edge becomes width-dependent, and the asymmetry because the shape requires more parameters to describe and measure. Modeling was performed by JMONSEL (Java Monte Carlo Simulation of Secondary Electrons), which produces a predicted yield vs. position for a given sample shape and composition. The simulator produces a library of predicted profiles for varying sample geometry. Shape parameter values are adjusted until interpolation of the library with those values best matches the measured image. Profiles thereby determined agreed with those determined by transmission electron microscopy and critical dimension small-angle x-ray scattering to better than 1 nm.

  8. Scanning electron microscope measurement of width and shape of 10nm patterned lines using a JMONSEL-modeled library.

    Villarrubia, J S; Vladár, A E; Ming, B; Kline, R J; Sunday, D F; Chawla, J S; List, S

    2015-07-01

    The width and shape of 10nm to 12 nm wide lithographically patterned SiO2 lines were measured in the scanning electron microscope by fitting the measured intensity vs. position to a physics-based model in which the lines' widths and shapes are parameters. The approximately 32 nm pitch sample was patterned at Intel using a state-of-the-art pitch quartering process. Their narrow widths and asymmetrical shapes are representative of near-future generation transistor gates. These pose a challenge: the narrowness because electrons landing near one edge may scatter out of the other, so that the intensity profile at each edge becomes width-dependent, and the asymmetry because the shape requires more parameters to describe and measure. Modeling was performed by JMONSEL (Java Monte Carlo Simulation of Secondary Electrons), which produces a predicted yield vs. position for a given sample shape and composition. The simulator produces a library of predicted profiles for varying sample geometry. Shape parameter values are adjusted until interpolation of the library with those values best matches the measured image. Profiles thereby determined agreed with those determined by transmission electron microscopy and critical dimension small-angle x-ray scattering to better than 1 nm. Published by Elsevier B.V.

  9. Design of a tracking device for on-line dose monitoring in hadrontherapy

    Battistoni, G. [INFN Sezione di Milano, Milano (Italy); Collamati, F.; De Lucia, E. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); Faccini, R. [Dipartimento di Fisica, “La Sapienza” Università di Roma, Roma (Italy); INFN Sezione di Roma, Roma (Italy); Marafini, M. [INFN Sezione di Roma, Roma (Italy); Museo Storico della Fisica e Centro Studi e Ricerche “E. Fermi”, Roma (Italy); Mattei, I. [INFN Sezione di Milano, Milano (Italy); Muraro, S., E-mail: silvia.muraro@mi.infn.it [INFN Sezione di Milano, Milano (Italy); Paramatti, R. [INFN Sezione di Roma, Roma (Italy); Patera, V. [INFN Sezione di Roma, Roma (Italy); Museo Storico della Fisica e Centro Studi e Ricerche “E. Fermi”, Roma (Italy); Dipartimento di Scienze di Base e Applicate per Ingegneria, “La Sapienza” Università di Roma, Roma (Italy); Pinci, D. [INFN Sezione di Roma, Roma (Italy); Rucinski, A. [INFN Sezione di Roma, Roma (Italy); Dipartimento di Scienze di Base e Applicate per Ingegneria, “La Sapienza” Università di Roma, Roma (Italy); Russomando, A. [Dipartimento di Fisica, “La Sapienza” Università di Roma, Roma (Italy); INFN Sezione di Roma, Roma (Italy); Center for Life Nano Science@Sapienza, Istituto Italiano di Tecnologia, Roma (Italy); and others

    2017-02-11

    Hadrontherapy is a technique for cancer treatment that exploits ion beams (mostly protons and carbons). A critical issue is the accuracy that is achievable when monitoring the dose released by the beam to the tumor and to the surrounding tissues. We present the design of a tracking device, developed in the framework of the INSIDE project , capable of monitoring in real time the longitudinal profile of the dose delivered in the patient. This is possible by detecting the secondary particles produced by the interaction of the beam in the tissues. The position of the Bragg peak can be correlated to the charged particles emission point distribution measurement. The tracking device will be able to provide a fast response on the dose pattern by tracking the secondary charged fragments. The tracks are detected using 6 planes of scintillating fibers, providing the 3D coordinates of the track intersection with each plane. The fibers planes are followed by a plastic scintillator and by a small calorimeter built with a pixelated Lutetium Fine Silicate (LFS) crystal. A complete detector simulation, followed by the event reconstruction, has been performed to determine the achievable monitoring spatial resolution. - Highlights: • On-line range monitoring in hadrontherapy. • New approach: detection of charged secondary particles escaping the patient. • Correlation of longitudinal emission profile of secondaries with the beam range. • New detector integrated in a multi-modal system to be tested in clinical operation.

  10. The effect of sidewall roughness on line edge roughness in top-down scanning electron microscopy images

    Verduin, T.; Lokhorst, S. R.; Kruit, P.; Hagen, C. W.

    2015-03-01

    We have investigated in a numerical study the determination of sidewall roughness (SWR) from top down scanning electron microscopy (SEM) images. In a typical metrology application, top-down SEM images are acquired in a (critical-dimension) SEM and the roughness is analyzed. However, the true size, shape and roughness characteristics of resist features are not fully investigated in the analysis of top-down SEM images. In reality, rough resist features are complex three-dimensional structures and the characterization naturally extends to the analysis of SWR. In this study we randomly generate images of rough lines and spaces, where the lines are made of PMMA on a silicon substrate. The lines that we study have a length of 2 µm, a width of 32nm and a height of 32 nm. The SWR is modeled by using the power spectral density (PSD) function of Palasantzas, which characterizes roughness by the standard deviation σ, correlation length ξ and roughness exponent α . The actual roughness is generated by application of the method of Thorsos in two dimensions. The images are constructed by using a home-built program for simulating electron-specimen interactions. The program that we have developed is optimized for complex arbitrary geometries and large number of incident low energy primary electrons by using multi-core CPUs and GPUs. The program uses the dielectric function model for inelastic scattering events and has an implementation specifically for low energy electrons. A satisfactory comparison is made between the secondary electron yields from the home-built program and another program found in literature. In order to reduce the risk of shrinkage, we use a beam energy of 300 eV and a spot size of 3 nm. Each pixel is exposed with 20 electrons on average (≍ 276 µC/cm2), following the Poisson distribution to account for illumination shot noise. We have assumed that the detection of electrons is perfect and does not introduce additional noise. We measure line edge

  11. The EPICS-based remote control system for muon beam line devices at J-PARC MUSE

    Ito, T. U.; Nakahara, K.; Kawase, M.; Fujimori, H.; Kobayashi, Y.; Higemoto, W.; Miyake, Y.

    2010-04-01

    The remote control system for muon beam line devices of J-PARC MUSE has been developed with the Experimental Physics and Industrial Control System (EPICS). The EPICS input/output controller was installed in standard Linux PCs for slow control of the devices. Power supplies for 21 magnetic elements and four slit controllers for the decay-surface muon beam line in the Materials and Life Science Experimental Facility are now accessible via Ethernet from a graphical user interface which has been composed using the Motif Editor and Display Manger.

  12. A new multi-line cusp magnetic field plasma device (MPD) with variable magnetic field

    Patel, A. D.; Sharma, M.; Ramasubramanian, N.; Ganesh, R.; Chattopadhyay, P. K.

    2018-04-01

    A new multi-line cusp magnetic field plasma device consisting of electromagnets with core material has been constructed with a capability to experimentally control the relative volume fractions of magnetized to unmagnetized plasma volume as well as accurate control on the gradient length scales of mean density and temperature profiles. Argon plasma has been produced using a hot tungsten cathode over a wide range of pressures 5 × 10-5 -1 × 10-3 mbar, achieving plasma densities ranging from 109 to 1011 cm-3 and the electron temperature in the range 1-8 eV. The radial profiles of plasma parameters measured along the non-cusp region (in between two consecutive magnets) show a finite region with uniform and quiescent plasma, where the magnetic field is very low such that the ions are unmagnetized. Beyond that region, both plasma species are magnetized and the profiles show gradients both in temperature and density. The electrostatic fluctuation measured using a Langmuir probe radially along the non-cusp region shows less than 1% (δIisat/Iisat physics parameter space relevant to both laboratory multi-scale plasmas and astrophysical plasmas.

  13. Effects of stochastic field lines on the pressure driven MHD instabilities in the Large Helical Device

    Ohdachi, Satoshi; Watanabe, Kiyomasa; Sakakibara, Satoru; Suzuki, Yasuhiro; Tsuchiya, Hayato; Ming, Tingfeng; Du, Xiaodi; LHD Expriment Group Team

    2014-10-01

    In the Large Helical Device (LHD), the plasma is surrounded by the so-called magnetic stochastic region, where the Kolmogorov length of the magnetic field lines is very short, from several tens of meters and to thousands meters. Finite pressure gradient are formed in this region and MHD instabilities localized in this region is observed since the edge region of the LHD is always unstable against the pressure driven mode. Therefore, the saturation level of the instabilities is the key issue in order to evaluate the risk of this kind of MHD instabilities. The saturation level depends on the pressure gradient and on the magnetic Reynolds number; there results are similar to the MHD mode in the closed magnetic surface region. The saturation level in the stochastic region is affected also by the stocasticity itself. Parameter dependence of the saturation level of the MHD activities in the region is discussed in detail. It is supported by NIFS budget code ULPP021, 028 and is also partially supported by the Ministry of Education, Science, Sports and Culture, Grant-in-Aid for Scientific Research 26249144, by the JSPS-NRF-NSFC A3 Foresight Program NSFC: No. 11261140328.

  14. The con focal laser scanning microscope: a powerful tool for the investigation of micro devices and nano structures

    Montereali, R.M.; Baldacchini, G.; Bonfigli, F.; Vincenti, M.A.; Almaviva, S.

    2008-01-01

    In the last years the Con focal Laser Scanning Microscope (CLSM), a versatile and powerful optical instrument, gained a strong increase of interest in the scientific community, not only for biological applications, but also for the characterization of materials, microstructures and devices. The conditions that favoured its wide diffusion are surely the large availability of laser sources and powerful computer-imaging and data-processing systems at relatively low cost; however, the main reason that contributed to its popularity is the ability to obtain tri dimensional reconstruction of a great variety of biological and non-biological samples with sub micrometric resolution. In this report we show the main properties and characteristics of the Con focal Microscope Nikon Eclipse 80-i C1, which has operated sinc more than two years in the Solid State Laser and Spectroscopy Laboratory of the ENEA Research Center in Frascati. Some of the results obtained in the characterization of luminescent micro and nano structures based on lithium fluoride color centers will be presented [it

  15. Study on the dose response characteristics of a scanning liquid ion-chamber electronic portal imaging device

    Ma Shao Gang; Song Yi Xin

    2002-01-01

    Objective: To study the dose response characteristics and the influence factors such as gantry angle, field size and acquisition mode on the dosimetric response curves, when using a scanning liquid ion-chamber electronic portal imaging device (EPID) for dose verification. Methods: All experiments were carried out on a Varian 600 C/D accelerator (6 MV X-ray) equipped with a Varian PortalVision sup T sup M MK2 type EPID. To obtain the dose response curve, the relationship between the incident radiation intensity to the detector and the pixel value output from the EPID were established. Firstly, the different dose rates of 6 MV X-rays were obtained by varying SSD. Secondly, three digital portal images were acquired for each dose rate using the EPID and averaged to avoid the influence of the dose rate fluctuations of the accelerator. The pixel values of all images were read using self-designed image analysis software, and and average for a region consisting of 11 x 11 pixels around the center was taken as the res...

  16. Neon-like Iron Ion Lines Measured in NIFS/Large Helical Device (LHD) and Hinode /EUV Imaging Spectrometer (EIS)

    Watanabe, Tetsuya; Hara, Hirohisa [National Astronomical Observatory, National Institutes of Natural Sciences 2-21-1 Osawa Mitaka Tokyo, 181-8588 (Japan); Murakami, Izumi; Kato, Daiji; Morita, Shigeru [SOKENDAI (Graduate University for Advanced Studies) Hayama, Miura-gun, Kanagawa, 240-0193 (Japan); Sakaue, Hiroyuki A.; Suzuki, Chihiro; Tamura, Naoki [National Institute for Fusion Science, National Institutes of Natural Sciences 322-6 Oroshi-cho, Toki Gifu, 509-5292 (Japan); Yamamoto, Norimasa [Chubu University 1200 Matsumoto-cho, Kasugai Aichi, 487-0027 (Japan); Nakamura, Nobuyuki, E-mail: watanabe@uvlab.mtk.nao.ac.jp [The University of Electro-Communications 1-5-1 Chofugaoka, Chofu Tokyo, 182-8585 (Japan)

    2017-06-10

    Line intensities emerging from the Ne-sequence iron ion (Fe xvii) are measured in the laboratory, by the Large Helical Device at the National Institute for Fusion Science, and in the solar corona by the EUV Imaging Spectrometer (EIS) on board the Hinode mission. The intensity ratios of Fe xvii λ 204.6/ λ 254.8 are derived in the laboratory by unblending the contributions of the Fe xiii and xii line intensities. They are consistent with theoretical predictions and solar observations, the latter of which endorses the in-flight radiometric calibrations of the EIS instrument. The still remaining temperature-dependent behavior of the line ratio suggests the contamination of lower-temperature iron lines that are blended with the λ 204.6 line.

  17. POINT CLOUD ANALYSIS FOR UAV-BORNE LASER SCANNING WITH HORIZONTALLY AND VERTICALLY ORIENTED LINE SCANNERS – CONCEPT AND FIRST RESULTS

    M. Weinmann

    2017-08-01

    Full Text Available In this paper, we focus on UAV-borne laser scanning with the objective of densely sampling object surfaces in the local surrounding of the UAV. In this regard, using a line scanner which scans along the vertical direction and perpendicular to the flight direction results in a point cloud with low point density if the UAV moves fast. Using a line scanner which scans along the horizontal direction only delivers data corresponding to the altitude of the UAV and thus a low scene coverage. For these reasons, we present a concept and a system for UAV-borne laser scanning using multiple line scanners. Our system consists of a quadcopter equipped with horizontally and vertically oriented line scanners. We demonstrate the capabilities of our system by presenting first results obtained for a flight within an outdoor scene. Thereby, we use a downsampling of the original point cloud and different neighborhood types to extract fundamental geometric features which in turn can be used for scene interpretation with respect to linear, planar or volumetric structures.

  18. High-resolution line-scan analysis of resin-embedded sediments using laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS)

    Hennekam, Rick; Jilbert, Tom; Mason, Paul R D; de Lange, Gert J.; Reichart, Gert Jan

    2015-01-01

    Laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) line-scanning is a promising technique for producing high-resolution (μm-scale) geochemical records on resin-embedded sediments. However, this approach has not yet been thoroughly tested on sediment samples of known elemental

  19. High-resolution line-scan analysis of resin-embedded sediments using laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS)

    Hennekam, R.; Jilbert, T.; de Lange, G.J.; Reichart, G.J.

    2015-01-01

    Laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) line-scanning is a promising technique for producing high-resolution (µm-scale) geochemical records on resin-embedded sediments. However, this approach has not yet been thoroughly tested on sediment samples of known elemental

  20. Radial line-scans as representative sampling strategy in dried-droplet laser ablation of liquid samples deposited on pre-cut filter paper disks

    Nischkauer, Winfried; Vanhaecke, Frank; Bernacchi, Sébastien; Herwig, Christoph; Limbeck, Andreas

    2014-11-01

    Nebulising liquid samples and using the aerosol thus obtained for further analysis is the standard method in many current analytical techniques, also with inductively coupled plasma (ICP)-based devices. With such a set-up, quantification via external calibration is usually straightforward for samples with aqueous or close-to-aqueous matrix composition. However, there is a variety of more complex samples. Such samples can be found in medical, biological, technological and industrial contexts and can range from body fluids, like blood or urine, to fuel additives or fermentation broths. Specialized nebulizer systems or careful digestion and dilution are required to tackle such demanding sample matrices. One alternative approach is to convert the liquid into a dried solid and to use laser ablation for sample introduction. Up to now, this approach required the application of internal standards or matrix-adjusted calibration due to matrix effects. In this contribution, we show a way to circumvent these matrix effects while using simple external calibration for quantification. The principle of representative sampling that we propose uses radial line-scans across the dried residue. This compensates for centro-symmetric inhomogeneities typically observed in dried spots. The effectiveness of the proposed sampling strategy is exemplified via the determination of phosphorus in biochemical fermentation media. However, the universal viability of the presented measurement protocol is postulated. Detection limits using laser ablation-ICP-optical emission spectrometry were in the order of 40 μg mL- 1 with a reproducibility of 10 % relative standard deviation (n = 4, concentration = 10 times the quantification limit). The reported sensitivity is fit-for-purpose in the biochemical context described here, but could be improved using ICP-mass spectrometry, if future analytical tasks would require it. Trueness of the proposed method was investigated by cross-validation with

  1. On-line Monitoring Device for High-voltage Switch Cabinet Partial Discharge Based on Pulse Current Method

    Y Tao, S.; Zhang, X. Z.; Cai, H. W.; Li, P.; Feng, Y.; Zhang, T. C.; Li, J.; Wang, W. S.; Zhang, X. K.

    2017-12-01

    The pulse current method for partial discharge detection is generally applied in type testing and other off-line tests of electrical equipment at delivery. After intensive analysis of the present situation and existing problems of partial discharge detection in switch cabinets, this paper designed the circuit principle and signal extraction method for partial discharge on-line detection based on a high-voltage presence indicating systems (VPIS), established a high voltage switch cabinet partial discharge on-line detection circuit based on the pulse current method, developed background software integrated with real-time monitoring, judging and analyzing functions, carried out a real discharge simulation test on a real-type partial discharge defect simulation platform of a 10KV switch cabinet, and verified the sensitivity and validity of the high-voltage switch cabinet partial discharge on-line monitoring device based on the pulse current method. The study presented in this paper is of great significance for switch cabinet maintenance and theoretical study on pulse current method on-line detection, and has provided a good implementation method for partial discharge on-line monitoring devices for 10KV distribution network equipment.

  2. Impact of Spot Size and Beam-Shaping Devices on the Treatment Plan Quality for Pencil Beam Scanning Proton Therapy

    Moteabbed, Maryam, E-mail: mmoteabbed@partners.org; Yock, Torunn I.; Depauw, Nicolas; Madden, Thomas M.; Kooy, Hanne M.; Paganetti, Harald

    2016-05-01

    Purpose: This study aimed to assess the clinical impact of spot size and the addition of apertures and range compensators on the treatment quality of pencil beam scanning (PBS) proton therapy and to define when PBS could improve on passive scattering proton therapy (PSPT). Methods and Materials: The patient cohort included 14 pediatric patients treated with PSPT. Six PBS plans were created and optimized for each patient using 3 spot sizes (∼12-, 5.4-, and 2.5-mm median sigma at isocenter for 90- to 230-MeV range) and adding apertures and compensators to plans with the 2 larger spots. Conformity and homogeneity indices, dose-volume histogram parameters, equivalent uniform dose (EUD), normal tissue complication probability (NTCP), and integral dose were quantified and compared with the respective PSPT plans. Results: The results clearly indicated that PBS with the largest spots does not necessarily offer a dosimetric or clinical advantage over PSPT. With comparable target coverage, the mean dose (D{sub mean}) to healthy organs was on average 6.3% larger than PSPT when using this spot size. However, adding apertures to plans with large spots improved the treatment quality by decreasing the average D{sub mean} and EUD by up to 8.6% and 3.2% of the prescribed dose, respectively. Decreasing the spot size further improved all plans, lowering the average D{sub mean} and EUD by up to 11.6% and 10.9% compared with PSPT, respectively, and eliminated the need for beam-shaping devices. The NTCP decreased with spot size and addition of apertures, with maximum reduction of 5.4% relative to PSPT. Conclusions: The added benefit of using PBS strongly depends on the delivery configurations. Facilities limited to large spot sizes (>∼8 mm median sigma at isocenter) are recommended to use apertures to reduce treatment-related toxicities, at least for complex and/or small tumors.

  3. In vitro studies of Rickettsia-host cell interactions: Confocal laser scanning microscopy of Rickettsia helvetica-infected eukaryotic cell lines.

    Speck, Stephanie; Kern, Tanja; Aistleitner, Karin; Dilcher, Meik; Dobler, Gerhard; Essbauer, Sandra

    2018-02-01

    Rickettsia (R.) helvetica is the most prevalent rickettsia found in Ixodes ricinus ticks in Germany. Several studies reported antibodies against R. helvetica up to 12.5% in humans investigated, however, fulminant clinical cases are rare indicating a rather low pathogenicity compared to other rickettsiae. We investigated growth characteristics of R. helvetica isolate AS819 in two different eukaryotic cell lines with focus on ultra-structural changes of host cells during infection determined by confocal laser scanning microscopy. Further investigations included partially sequencing of rickA, sca4 and sca2 genes, which have been reported to encode proteins involved in cell-to-cell spread and virulence in some rickettsiae. R. helvetica grew constantly but slowly in both cell lines used. Confocal laser scanning microscopy revealed that the dissemination of R. helvetica AS819 in both cell lines was rather mediated by cell break-down and bacterial release than cell-to-cell spread. The cytoskeleton of both investigated eukaryotic cell lines was not altered. R. helvetica possesses rickA, but its expression is not sufficient to promote actin-based motility as demonstrated by confocal laser scanning microscopy. Hypothetical Sca2 and Sca4 proteins were deduced from nucleotide gene sequences but the predicted amino acid sequences were disrupted or truncated compared to other rickettsiae most likely resulting in non-functional proteins. Taken together, these results might give a first hint to the underlying causes of the reduced virulence and pathogenicity of R. helvetica.

  4. A versatile LabVIEW and field-programmable gate array-based scanning probe microscope for in operando electronic device characterization.

    Berger, Andrew J; Page, Michael R; Jacob, Jan; Young, Justin R; Lewis, Jim; Wenzel, Lothar; Bhallamudi, Vidya P; Johnston-Halperin, Ezekiel; Pelekhov, Denis V; Hammel, P Chris

    2014-12-01

    Understanding the complex properties of electronic and spintronic devices at the micro- and nano-scale is a topic of intense current interest as it becomes increasingly important for scientific progress and technological applications. In operando characterization of such devices by scanning probe techniques is particularly well-suited for the microscopic study of these properties. We have developed a scanning probe microscope (SPM) which is capable of both standard force imaging (atomic, magnetic, electrostatic) and simultaneous electrical transport measurements. We utilize flexible and inexpensive FPGA (field-programmable gate array) hardware and a custom software framework developed in National Instrument's LabVIEW environment to perform the various aspects of microscope operation and device measurement. The FPGA-based approach enables sensitive, real-time cantilever frequency-shift detection. Using this system, we demonstrate electrostatic force microscopy of an electrically biased graphene field-effect transistor device. The combination of SPM and electrical transport also enables imaging of the transport response to a localized perturbation provided by the scanned cantilever tip. Facilitated by the broad presence of LabVIEW in the experimental sciences and the openness of our software solution, our system permits a wide variety of combined scanning and transport measurements by providing standardized interfaces and flexible access to all aspects of a measurement (input and output signals, and processed data). Our system also enables precise control of timing (synchronization of scanning and transport operations) and implementation of sophisticated feedback protocols, and thus should be broadly interesting and useful to practitioners in the field.

  5. The device for the poloidal profile measurement of H sub(α)-line emission by photodiode and its calibration

    Miura, Yukitoshi; Kasai, Satoshi; Tamai, Hiroshi; Hasegawa, Koichi

    1985-11-01

    The device for the poloidal profile measurement of H sub(α)-line emission has been equipped by photodiode (S1225-5BQ by HAMAMATSU PHOTONICS K.K.) and operational amplifier. The absolute efficiency was calibrated by using He-Ne laser. The device is constructed by 44 channels. The fast type of 8 channels is for the monitor of pellet abration profile. The slow type of 36 channels is for the poloidal profile measurement of H sub(α)-line emission from JFT-2M plasma. The rise time of the fast type and the slow type is about 2.8 μsec and about 350 μsec, respectively. The absolute efficiency of the fast type and the slow type is 72.7 V/mW and 18.2 V/μW, respectively. (author)

  6. Developing a reproducible non-line-of-sight experimental setup for testing wireless medical device coexistence utilizing ZigBee.

    LaSorte, Nickolas J; Rajab, Samer A; Refai, Hazem H

    2012-11-01

    The integration of heterogeneous wireless technologies is believed to aid revolutionary healthcare delivery in hospitals and residential care. Wireless medical device coexistence is a growing concern given the ubiquity of wireless technology. In spite of this, a consensus standard that addresses risks associated with wireless heterogeneous networks has not been adopted. This paper serves as a starting point by recommending a practice for assessing the coexistence of a wireless medical device in a non-line-of-sight environment utilizing 802.15.4 in a practical, versatile, and reproducible test setup. This paper provides an extensive survey of other coexistence studies concerning 802.15.4 and 802.11 and reports on the authors' coexistence testing inside and outside an anechoic chamber. Results are compared against a non-line-of-sight test setup. Findings relative to co-channel and adjacent channel interference were consistent with results reported in the literature.

  7. Impact of Spot Size and Beam-Shaping Devices on the Treatment Plan Quality for Pencil Beam Scanning Proton Therapy

    Moteabbed, Maryam; Yock, Torunn I.; Depauw, Nicolas; Madden, Thomas M.; Kooy, Hanne M.; Paganetti, Harald

    2016-01-01

    Purpose: This study aimed to assess the clinical impact of spot size and the addition of apertures and range compensators on the treatment quality of pencil beam scanning (PBS) proton therapy and to define when PBS could improve on passive scattering proton therapy (PSPT). Methods and Materials: The patient cohort included 14 pediatric patients treated with PSPT. Six PBS plans were created and optimized for each patient using 3 spot sizes (∼12-, 5.4-, and 2.5-mm median sigma at isocenter for 90- to 230-MeV range) and adding apertures and compensators to plans with the 2 larger spots. Conformity and homogeneity indices, dose-volume histogram parameters, equivalent uniform dose (EUD), normal tissue complication probability (NTCP), and integral dose were quantified and compared with the respective PSPT plans. Results: The results clearly indicated that PBS with the largest spots does not necessarily offer a dosimetric or clinical advantage over PSPT. With comparable target coverage, the mean dose (D_m_e_a_n) to healthy organs was on average 6.3% larger than PSPT when using this spot size. However, adding apertures to plans with large spots improved the treatment quality by decreasing the average D_m_e_a_n and EUD by up to 8.6% and 3.2% of the prescribed dose, respectively. Decreasing the spot size further improved all plans, lowering the average D_m_e_a_n and EUD by up to 11.6% and 10.9% compared with PSPT, respectively, and eliminated the need for beam-shaping devices. The NTCP decreased with spot size and addition of apertures, with maximum reduction of 5.4% relative to PSPT. Conclusions: The added benefit of using PBS strongly depends on the delivery configurations. Facilities limited to large spot sizes (>∼8 mm median sigma at isocenter) are recommended to use apertures to reduce treatment-related toxicities, at least for complex and/or small tumors.

  8. High-resolution room-temperature sample scanning superconducting quantum interference device microscope configurable for geological and biomagnetic applications

    Fong, L. E.; Holzer, J. R.; McBride, K. K.; Lima, E. A.; Baudenbacher, F.; Radparvar, M.

    2005-05-01

    We have developed a scanning superconducting quantum interference device (SQUID) microscope system with interchangeable sensor configurations for imaging magnetic fields of room-temperature (RT) samples with submillimeter resolution. The low-critical-temperature (Tc) niobium-based monolithic SQUID sensors are mounted on the tip of a sapphire and thermally anchored to the helium reservoir. A 25μm sapphire window separates the vacuum space from the RT sample. A positioning mechanism allows us to adjust the sample-to-sensor spacing from the top of the Dewar. We achieved a sensor-to-sample spacing of 100μm, which could be maintained for periods of up to four weeks. Different SQUID sensor designs are necessary to achieve the best combination of spatial resolution and field sensitivity for a given source configuration. For imaging thin sections of geological samples, we used a custom-designed monolithic low-Tc niobium bare SQUID sensor, with an effective diameter of 80μm, and achieved a field sensitivity of 1.5pT/Hz1/2 and a magnetic moment sensitivity of 5.4×10-18Am2/Hz1/2 at a sensor-to-sample spacing of 100μm in the white noise region for frequencies above 100Hz. Imaging action currents in cardiac tissue requires a higher field sensitivity, which can only be achieved by compromising spatial resolution. We developed a monolithic low-Tc niobium multiloop SQUID sensor, with sensor sizes ranging from 250μm to 1mm, and achieved sensitivities of 480-180fT /Hz1/2 in the white noise region for frequencies above 100Hz, respectively. For all sensor configurations, the spatial resolution was comparable to the effective diameter and limited by the sensor-to-sample spacing. Spatial registration allowed us to compare high-resolution images of magnetic fields associated with action currents and optical recordings of transmembrane potentials to study the bidomain nature of cardiac tissue or to match petrography to magnetic field maps in thin sections of geological samples.

  9. Comparison of the biometric values obtained by two different A-mode ultrasound devices (Eye Cubed vs. PalmScan): a transversal, descriptive, and comparative study.

    Velez-Montoya, Raul; Shusterman, Eugene Mark; López-Miranda, Miriam Jessica; Mayorquin-Ruiz, Mariana; Salcedo-Villanueva, Guillermo; Quiroz-Mercado, Hugo; Morales-Cantón, Virgilio

    2010-03-24

    To assess the reliability of the measurements obtained with the PalmScan, when compared with another standardized A-mode ultrasound device, and assess the consistency and correlation between the two methods. Transversal, descriptive, and comparative study. We recorded the axial length (AL), anterior chamber depth (ACD) and lens thickness (LT) obtained with two A-mode ultrasounds (PalmScan A2000 and Eye Cubed) using an immersion technique. We compared the measurements with a two-sample t-test. Agreement between the two devices was assessed with Bland-Altman plots and 95% limits of agreement. 70 eyes of 70 patients were enrolled in this study. The measurements with the Eye Cubed of AL and ACD were shorter than the measurements taken by the PalmScan. The differences were not statistically significant regarding AL (p < 0.4) but significant regarding ACD (p < 0.001). The highest agreement between the two devices was obtained during LT measurement. The PalmScan measurements were shorter, but not statistically significantly (p < 0.2). The values of AL and LT, obtained with both devices are not identical, but within the limits of agreement. The agreement is not affected by the magnitude of the ocular dimensions (but only between range of 20 mm to 27 mm of AL and 3.5 mm to 5.7 mm of LT). A correction of about 0.5 D could be considered if an intraocular lens is being calculated. However due to the large variability of the results, the authors recommend discretion in using this conversion factor, and to adjust the power of the intraocular lenses based upon the personal experience of the surgeon.

  10. Angular on-line tube current modulation in multidetector CT examinations of children and adults: The influence of different scanning parameters on dose reduction

    Papadakis, Antonios E.; Perisinakis, Kostas; Damilakis, John

    2007-01-01

    The purpose of this study was to assess the potential of angular on-line tube current modulation on dose reduction in pediatric and adult patients undergoing multidetector computed tomography (MDCT) examinations. Five physical anthropomorphic phantoms that simulate the average individual as neonate, 1-year-old, 5-year-old, 10-year-old, and adult were employed in the current study. Phantoms were scanned with the use of on-line tube current modulation (TCM). Percent dose reduction (%DR) factors achieved by applying TCM, were determined for standard protocols used for head and neck, shoulder, thorax, thorax and abdomen, abdomen, abdomen and pelvis, pelvis, and whole body examinations. A preliminary study on the application of TCM in MDCT examinations of adult patients was performed to validate the results obtained in anthropomorphic phantoms. Dose reduction was estimated as the percentage difference of the modulated milliamperes for each scan and the preset milliamperes prescribed by the scan protocol. The dose reduction in children was found to be much lower than the corresponding reduction achieved for adults. For helical scans the %DR factors, ranged between 1.6% and 7.4% for the neonate, 2.9% and 8.7% for the 1-year old, 2% and 6% for the 5-year-old, 5% and 10.9% for the 10-year-old, and 10.4% and 20.7% for the adult individual. For sequential scans the corresponding %DR factors ranged between 1.3% and 6.7%, 4.5% and 11%, 4.2% and 6.6%, 6.4% and 12.3%, and 8.9% and 23.3%, respectively. Broader beam collimations are associated with decreased %DR factors, when other scanning parameters are held constant. TCM did not impair image noise. In adult patients, the %DR values were found to be in good agreement with the corresponding results obtained in the anthropomorphic adult phantom. In conclusion, on-line TCM may be considered as a valuable tool for reducing dose in routine CT examinations of pediatric and adult patients. However, the dose reduction achieved with TCM

  11. Performance characteristics of a novel blood bag in-line closure device and subsequent product quality assessment

    Serrano, Katherine; Levin, Elena; Culibrk, Brankica; Weiss, Sandra; Scammell, Ken; Boecker, Wolfgang F; Devine, Dana V

    2010-01-01

    BACKGROUND In high-volume processing environments, manual breakage of in-line closures can result in repetitive strain injury (RSI). Furthermore, these closures may be incorrectly opened causing shear-induced hemolysis. To overcome the variability of in-line closure use and minimize RSI, Fresenius Kabi developed a new in-line closure, the CompoFlow, with mechanical openers. STUDY DESIGN AND METHODS The consistency of the performance of the CompoFlow closure device was assessed, as was its effect on component quality. A total of 188 RBC units using CompoFlow blood bag systems and 43 using the standard bag systems were produced using the buffy coat manufacturing method. Twenty-six CompoFlow platelet (PLT) concentrates and 10 control concentrates were prepared from pools of four buffy coats. RBCs were assessed on Days 1, 21, and 42 for cellular variables and hemolysis. PLTs were assessed on Days 1, 3, and 7 for morphology, CD62P expression, glucose, lactate, and pH. A total of 308 closures were excised after processing and the apertures were measured using digital image analysis. RESULTS The use of the CompoFlow device significantly improved the mean extraction time with 0.46 ± 0.11 sec/mL for the CompoFlow units and 0.52 ± 0.13 sec/mL for the control units. The CompoFlow closures showed a highly reproducible aperture after opening (coefficient of variation, 15%) and the device always remained opened. PLT and RBC products showed acceptable storage variables with no differences between CompoFlow and control. CONCLUSIONS The CompoFlow closure devices improved the level of process control and processing time of blood component production with no negative effects on product quality. PMID:20529007

  12. Radial line-scans as representative sampling strategy in dried-droplet laser ablation of liquid samples deposited on pre-cut filter paper disks.

    Nischkauer, Winfried; Vanhaecke, Frank; Bernacchi, Sébastien; Herwig, Christoph; Limbeck, Andreas

    2014-11-01

    Nebulising liquid samples and using the aerosol thus obtained for further analysis is the standard method in many current analytical techniques, also with inductively coupled plasma (ICP)-based devices. With such a set-up, quantification via external calibration is usually straightforward for samples with aqueous or close-to-aqueous matrix composition. However, there is a variety of more complex samples. Such samples can be found in medical, biological, technological and industrial contexts and can range from body fluids, like blood or urine, to fuel additives or fermentation broths. Specialized nebulizer systems or careful digestion and dilution are required to tackle such demanding sample matrices. One alternative approach is to convert the liquid into a dried solid and to use laser ablation for sample introduction. Up to now, this approach required the application of internal standards or matrix-adjusted calibration due to matrix effects. In this contribution, we show a way to circumvent these matrix effects while using simple external calibration for quantification. The principle of representative sampling that we propose uses radial line-scans across the dried residue. This compensates for centro-symmetric inhomogeneities typically observed in dried spots. The effectiveness of the proposed sampling strategy is exemplified via the determination of phosphorus in biochemical fermentation media. However, the universal viability of the presented measurement protocol is postulated. Detection limits using laser ablation-ICP-optical emission spectrometry were in the order of 40 μg mL - 1 with a reproducibility of 10 % relative standard deviation (n = 4, concentration = 10 times the quantification limit). The reported sensitivity is fit-for-purpose in the biochemical context described here, but could be improved using ICP-mass spectrometry, if future analytical tasks would require it. Trueness of the proposed method was investigated by cross-validation with

  13. Radial line-scans as representative sampling strategy in dried-droplet laser ablation of liquid samples deposited on pre-cut filter paper disks

    Nischkauer, Winfried [Institute of Chemical Technologies and Analytics, Vienna University of Technology, Vienna (Austria); Department of Analytical Chemistry, Ghent University, Ghent (Belgium); Vanhaecke, Frank [Department of Analytical Chemistry, Ghent University, Ghent (Belgium); Bernacchi, Sébastien; Herwig, Christoph [Institute of Chemical Engineering, Vienna University of Technology, Vienna (Austria); Limbeck, Andreas, E-mail: Andreas.Limbeck@tuwien.ac.at [Institute of Chemical Technologies and Analytics, Vienna University of Technology, Vienna (Austria)

    2014-11-01

    Nebulising liquid samples and using the aerosol thus obtained for further analysis is the standard method in many current analytical techniques, also with inductively coupled plasma (ICP)-based devices. With such a set-up, quantification via external calibration is usually straightforward for samples with aqueous or close-to-aqueous matrix composition. However, there is a variety of more complex samples. Such samples can be found in medical, biological, technological and industrial contexts and can range from body fluids, like blood or urine, to fuel additives or fermentation broths. Specialized nebulizer systems or careful digestion and dilution are required to tackle such demanding sample matrices. One alternative approach is to convert the liquid into a dried solid and to use laser ablation for sample introduction. Up to now, this approach required the application of internal standards or matrix-adjusted calibration due to matrix effects. In this contribution, we show a way to circumvent these matrix effects while using simple external calibration for quantification. The principle of representative sampling that we propose uses radial line-scans across the dried residue. This compensates for centro-symmetric inhomogeneities typically observed in dried spots. The effectiveness of the proposed sampling strategy is exemplified via the determination of phosphorus in biochemical fermentation media. However, the universal viability of the presented measurement protocol is postulated. Detection limits using laser ablation-ICP-optical emission spectrometry were in the order of 40 μg mL{sup −1} with a reproducibility of 10 % relative standard deviation (n = 4, concentration = 10 times the quantification limit). The reported sensitivity is fit-for-purpose in the biochemical context described here, but could be improved using ICP-mass spectrometry, if future analytical tasks would require it. Trueness of the proposed method was investigated by cross-validation with

  14. LINES

    Minas Bakalchev

    2015-10-01

    Full Text Available The perception of elements in a system often creates their interdependence, interconditionality, and suppression. The lines from a basic geometrical element have become the model of a reductive world based on isolation according to certain criteria such as function, structure, and social organization. Their traces are experienced in the contemporary world as fragments or ruins of a system of domination of an assumed hierarchical unity. How can one release oneself from such dependence or determinism? How can the lines become less “systematic” and forms more autonomous, and less reductive? How is a form released from modernistic determinism on the new controversial ground? How can these elements or forms of representation become forms of action in the present complex world? In this paper, the meaning of lines through the ideas of Le Corbusier, Leonidov, Picasso, and Hitchcock is presented. Spatial research was made through a series of examples arising from the projects of the architectural studio “Residential Transformations”, which was a backbone for mapping the possibilities ranging from playfulness to exactness, as tactics of transformation in the different contexts of the contemporary world.

  15. Desgin of On-line Monitoring Device for MOA (Metal Oxide Arrestor Based on FPGA and C8051F

    Xiaotong YAO

    2014-10-01

    Full Text Available Monitoring of metal oxide surge arresters (MOA due to aging, moisture and other components cause increased resistive current. Through a lot of practices, it has been proved that in the early days, MOA insulation damage and current increase is not obvious. The accurate working conditions of the MOA are also not obvious but it can reflect the aging or moisture of MOA. When the resistive current of the fundamental component increases, there is no increment in the harmonic components that is the general performance of a serious or moisture contamination. In the same way when the resistive current of harmonic components increases, the fundamental component is not increased and it is the general performance of aging. Therefore, this paper designed an experiment-based FPGA and C8051F-line monitoring device. This device uses resistive current as a detection target. The main monitoring parameters are the fundamental and peak value of resistive current, third harmonic content of the leakage current, phase angle difference and power consumption. Through laboratory tests, the device can be used with a network arrester line monitoring, maintenance, reduce the economic losses caused by power outages and improve the distribution network reliability.

  16. Design and evaluation of an on-line fuel rod assay device for an HTGR fuel refabrication plant

    Rushton, J.E.; Allen, E.J.; Chiles, M.M.; Jenkins, J.D.

    1979-11-01

    Refabricated HTGR fuel rods will contain from approx. 0.15 to 0.5 g 233 U and/or 235 U. The fuel rods are approx. 16 mm in diameter and 62 mm long. A typical commercial fuel refabrication facility will have six fuel rod production lines, each producing approximately one fuel rod every 4 seconds at design capacity. One on-line assay device will be present for each two production lines. The relative standard deviation in an individual fuel rod fissile material measurement must be less than 3% to satisfy process and quality control requirements. Systematic errors must be kept less than approx. 0.3% for fissile material measured in fuel rods produced over two months to satisfy material accountability requirements. Several nondestructive assay (NDA) methods were investigated. Because the gamma-ray activity of the refabricated fuel is relatively high due to the presence of 232 U in the fuel and because the gamma-ray activity is not directly related to total or fissile uranium content, NDA methods employing gamma-ray detection did not appear practicable. A method using thermal neutron irradiation and fast-fission neutron detection was selected. An experimental assay device was fabricated based on this NDA method. Experiments were performed to determine the precision and accuracy of the measurements and to investigate potential interferences and systematic errors. Operating procedures were evaluated, and analysis procedures were identified

  17. Reuse without Compromising Performance: Industrial Experience from RPG Software Product Line for Mobile Devices

    Zhang, Weishan; Jarzabek, Stan

    2005-01-01

    allowed us to achieve improved performance, both speed and memory utilization, as compared to each game developed individually. At the same time, our solution facilitated rapid development of new games, for new mobile devices, as well as ease of evolving with new features the RPG-PLA and custom games...

  18. Spectral survey of helium lines in a linear plasma device for use in HELIOS imaging

    Ray, H. B., E-mail: rayhb@ornl.gov [University of Tennessee, Knoxville, Tennessee 37996 (United States); Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 (United States); Biewer, T. M.; Fehling, D. T.; Isler, R. C.; Unterberg, E. A. [Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 (United States)

    2016-11-15

    Fast visible cameras and a filterscope are used to examine the visible light emission from Oak Ridge National Laboratory’s Proto-MPEX. The filterscope has been configured to perform helium line ratio measurements using emission lines at 667.9, 728.1, and 706.5 nm. The measured lines should be mathematically inverted and the ratios compared to a collisional radiative model (CRM) to determine T{sub e} and n{sub e}. Increasing the number of measurement chords through the plasma improves the inversion calculation and subsequent T{sub e} and n{sub e} localization. For the filterscope, one spatial chord measurement requires three photomultiplier tubes (PMTs) connected to pellicle beam splitters. Multiple, fast visible cameras with narrowband filters are an alternate technique for performing these measurements with superior spatial resolution. Each camera contains millions of pixels; each pixel is analogous to one filterscope PMT. The data can then be inverted and the ratios compared to the CRM to determine 2-dimensional “images” of T{sub e} and n{sub e} in the plasma. An assessment is made in this paper of the candidate He I emission lines for an imaging technique.

  19. Spectral survey of helium lines in a linear plasma device for use in HELIOS imaging

    Ray, H. B.; Biewer, T. M.; Fehling, D. T.; Isler, R. C.; Unterberg, E. A.

    2016-11-01

    Fast visible cameras and a filterscope are used to examine the visible light emission from Oak Ridge National Laboratory's Proto-MPEX. The filterscope has been configured to perform helium line ratio measurements using emission lines at 667.9, 728.1, and 706.5 nm. The measured lines should be mathematically inverted and the ratios compared to a collisional radiative model (CRM) to determine Te and ne. Increasing the number of measurement chords through the plasma improves the inversion calculation and subsequent Te and ne localization. For the filterscope, one spatial chord measurement requires three photomultiplier tubes (PMTs) connected to pellicle beam splitters. Multiple, fast visible cameras with narrowband filters are an alternate technique for performing these measurements with superior spatial resolution. Each camera contains millions of pixels; each pixel is analogous to one filterscope PMT. The data can then be inverted and the ratios compared to the CRM to determine 2-dimensional "images" of Te and ne in the plasma. An assessment is made in this paper of the candidate He I emission lines for an imaging technique.

  20. Microscopic studies of the fate of charges in organic semiconductors: Scanning Kelvin probe measurements of charge trapping, transport, and electric fields in p- and n-type devices

    Smieska, Louisa Marion

    Organic semiconductors could have wide-ranging applications in lightweight, efficient electronic circuits. However, several fundamental questions regarding organic electronic device behavior have not yet been fully addressed, including the nature of chemical charge traps, and robust models for injection and transport. Many studies focus on engineering devices through bulk transport measurements, but it is not always possible to infer the microscopic behavior leading to the observed measurements. In this thesis, we present scanning-probe microscope studies of organic semiconductor devices in an effort to connect local properties with local device behavior. First, we study the chemistry of charge trapping in pentacene transistors. Working devices are doped with known pentacene impurities and the extent of charge trap formation is mapped across the transistor channel. Trap-clearing spectroscopy is employed to measure an excitation of the pentacene charge trap species, enabling identification of the degradationrelated chemical trap in pentacene. Second, we examine transport and trapping in peryelene diimide (PDI) transistors. Local mobilities are extracted from surface potential profiles across a transistor channel, and charge injection kinetics are found to be highly sensitive to electrode cleanliness. Trap-clearing spectra generally resemble PDI absorption spectra, but one derivative yields evidence indicating variation in trap-clearing mechanisms for different surface chemistries. Trap formation rates are measured and found to be independent of surface chemistry, contradicting a proposed silanol trapping mechanism. Finally, we develop a variation of scanning Kelvin probe microscopy that enables measurement of electric fields through a position modulation. This method avoids taking a numeric derivative of potential, which can introduce high-frequency noise into the electric field signal. Preliminary data is presented, and the theoretical basis for electric field

  1. In-line monitoring of Li-ion battery electrode porosity and areal loading using active thermal scanning - modeling and initial experiment

    Rupnowski, Przemyslaw; Ulsh, Michael; Sopori, Bhushan; Green, Brian G.; Wood, David L.; Li, Jianlin; Sheng, Yangping

    2018-01-01

    This work focuses on a new technique called active thermal scanning for in-line monitoring of porosity and areal loading of Li-ion battery electrodes. In this technique a moving battery electrode is subjected to thermal excitation and the induced temperature rise is monitored using an infra-red camera. Static and dynamic experiments with speeds up to 1.5 m min-1 are performed on both cathodes and anodes and a combined micro- and macro-scale finite element thermal model of the system is developed. It is shown experimentally and through simulations that during thermal scanning the temperature profile generated in an electrode depends on both coating porosity (or area loading) and thickness. It is concluded that by inverting this relation the porosity (or areal loading) can be determined, if thermal response and thickness are simultaneously measured.

  2. Relationship Between the Elevated Muscle FDG Uptake in the Distal Upper Extremities on PET/CT Scan and Prescan Utilization of Mobile Devices in Young Patients.

    Bai, Xia; Wang, Xuemei; Zhuang, Hongming

    2018-03-01

    It is common to notice increased FDG activity in the muscles of the forearms or hands on PET/CT images. The purpose of this study was to determine relationship between the prevalence of increased FDG activity in the forearms or hands and using mobile devices prior to the FDG PET/CT study. A total of 443 young patients with ages between 5 and 19 years who underwent FDG PET/CT scan were included in this retrospective analysis. All patients had FDG PET/CT with their arms within the field of views. The images were reviewed for elevated activity in the muscles of the distal upper extremities (DUEs), which include forearms and hands. The preimaging questionnaire/interview records regarding using mobile devices prior to FDG PET/CT were also reviewed and compared with the imaging findings. Most patients (72.0% [319/443]) used mobile devices more than 60 minutes in the period of 24 hours prior to the FDG PET/CT study. Elevated uptake in the muscles in the DUEs was observed in 38.6% (123/319) of these patients. In contrast, among 124 patients who did not use the mobile devices or used the mobile device minimally prior to the study, only 6.5% (8/124) of them had elevated FDG activity in the DUEs. The difference persisted following stratification analysis for sex, age, and serum glucose level in our patient population. Increased FDG uptake in the muscles of the DUEs in young patients is commonly seen in those who used mobile devices prior to PET/CT study. Recommendation should be considered to reduce using mobile devices prior to FDG PET/CT study in young patient population.

  3. GRILLIX. A 3D turbulence code for magnetic fusion devices based on a field line map

    Stegmeir, Andreas Korbinian

    2015-01-01

    The complex geometry in the scrape-off layer of tokamaks poses problems to existing turbulence codes. The usually employed field aligned coordinates become ill defined at the separatrix. Therefore the parallel code GRILLIX was developed, which is based on a field line map. This allows simulations in additional complex geometries, especially across the separatrix. A new discretisation, based on the support operator method, for the highly anisotropic diffusion was developed and applied to a simple turbulence model (Hasegawa-Wakatani).

  4. Expansion of Smartwatch Touch Interface from Touchscreen to Around Device Interface Using Infrared Line Image Sensors

    Lim, Soo-Chul; Shin, Jungsoon; Kim, Seung-Chan; Park, Joonah

    2015-01-01

    Touchscreen interaction has become a fundamental means of controlling mobile phones and smartwatches. However, the small form factor of a smartwatch limits the available interactive surface area. To overcome this limitation, we propose the expansion of the touch region of the screen to the back of the user’s hand. We developed a touch module for sensing the touched finger position on the back of the hand using infrared (IR) line image sensors, based on the calibrated IR intensity and the maxi...

  5. Eine elektronische Linienkamera fuer die Tomografie von Brennelementen mit durchdringenden Strahlen. An electronic line scan camera for tomographic evaluation of fuel assemblies using penetrating radiation

    Steinbock, L.

    1988-01-01

    The described electronic line scan camaera saves time and costs in taking radiographs and tompgraphs in nuclear facilities. The pictures being taken on polaroid films, there is no need for expensive laboratory work as for the X-ray films. The immediate digitalisation of the signals (saves) expensive digitalisation of X-ray films and allows to record the data of the pictures on cheap magnetic or optical disc. The data can later be processed by the common image analysing methods. Spatial resolutions achieved up to now are about 0.3 mm both for shadow radiography and tomography. (orig.) [de

  6. An on-line identification device for coal and gangue based on dual-energy γ-ray transmission and microcontroller

    Chen Guojie; Zhu Xing

    2004-01-01

    The operating principle, hardware design, software design and stabled-spectrum method of on-line identification device for coal and gangue based on dual-energy γ-ray transmission and microcontroller are introduced. The integrated linear amplifier and integrated single channel pulse height analyzer are analyzed. The on-line identification device has advantages of small size, low cost as well stabilization. (authors)

  7. Safety catching device for pipe lines in missile shielding cylinders of nuclear power plants

    Hering, S.; Doll, B.

    1975-01-01

    The safety catching device for pipes in the missile shielding cylinders consists of a flexible steel cable surrounding the pipe in a distance in U-shape. The arrester cable - which works as a spring and is freely movable in all directions - is attached to the cylinder wall. For this, the ends of the cable are primarily fastened to anchor boxes which are then inserted in a stay tube with the same axis as the cable ends. The anchor boxes are fastened to the outer wall of the missile shielding cylinder by anchor bolts and holding plates. (DG/AK) [de

  8. On-line integration of computer controlled diagnostic devices and medical information systems in undergraduate medical physics education for physicians.

    Hanus, Josef; Nosek, Tomas; Zahora, Jiri; Bezrouk, Ales; Masin, Vladimir

    2013-01-01

    We designed and evaluated an innovative computer-aided-learning environment based on the on-line integration of computer controlled medical diagnostic devices and a medical information system for use in the preclinical medical physics education of medical students. Our learning system simulates the actual clinical environment in a hospital or primary care unit. It uses a commercial medical information system for on-line storage and processing of clinical type data acquired during physics laboratory classes. Every student adopts two roles, the role of 'patient' and the role of 'physician'. As a 'physician' the student operates the medical devices to clinically assess 'patient' colleagues and records all results in an electronic 'patient' record. We also introduced an innovative approach to the use of supportive education materials, based on the methods of adaptive e-learning. A survey of student feedback is included and statistically evaluated. The results from the student feedback confirm the positive response of the latter to this novel implementation of medical physics and informatics in preclinical education. This approach not only significantly improves learning of medical physics and informatics skills but has the added advantage that it facilitates students' transition from preclinical to clinical subjects. Copyright © 2011 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  9. Optimization Design of an Inductive Energy Harvesting Device for Wireless Power Supply System Overhead High-Voltage Power Lines

    Wei Wang

    2016-03-01

    Full Text Available Overhead high voltage power line (HVPL online monitoring equipment is playing an increasingly important role in smart grids, but the power supply is an obstacle to such systems’ stable and safe operation, so in this work a hybrid wireless power supply system, integrated with inductive energy harvesting and wireless power transmitting, is proposed. The energy harvesting device extracts energy from the HVPL and transfers that from the power line to monitoring equipment on transmission towers by transmitting and receiving coils, which are in a magnetically coupled resonant configuration. In this paper, the optimization design of online energy harvesting devices is analyzed emphatically by taking both HVPL insulation distance and wireless power supply efficiency into account. It is found that essential parameters contributing to more extracted energy include large core inner radius, core radial thickness, core height and small core gap within the threshold constraints. In addition, there is an optimal secondary coil turn that can maximize extracted energy when other parameters remain fixed. A simple and flexible control strategy is then introduced to limit power fluctuations caused by current variations. The optimization methods are finally verified experimentally.

  10. 3D Participatory Sensing with Low-Cost Mobile Devices for Crop Height Assessment--A Comparison with Terrestrial Laser Scanning Data.

    Sabrina Marx

    Full Text Available The integration of local agricultural knowledge deepens the understanding of complex phenomena such as the association between climate variability, crop yields and undernutrition. Participatory Sensing (PS is a concept which enables laymen to easily gather geodata with standard low-cost mobile devices, offering new and efficient opportunities for agricultural monitoring. This study presents a methodological approach for crop height assessment based on PS. In-field crop height variations of a maize field in Heidelberg, Germany, are gathered with smartphones and handheld GPS devices by 19 participants. The comparison of crop height values measured by the participants to reference data based on terrestrial laser scanning (TLS results in R2 = 0.63 for the handheld GPS devices and R2 = 0.24 for the smartphone-based approach. RMSE for the comparison between crop height models (CHM derived from PS and TLS data is 10.45 cm (GPS devices and 14.69 cm (smartphones. Furthermore, the results indicate that incorporating participants' cognitive abilities in the data collection process potentially improves the quality data captured with the PS approach. The proposed PS methods serve as a fundament to collect agricultural parameters on field-level by incorporating local people. Combined with other methods such as remote sensing, PS opens new perspectives to support agricultural development.

  11. 3D Participatory Sensing with Low-Cost Mobile Devices for Crop Height Assessment--A Comparison with Terrestrial Laser Scanning Data.

    Marx, Sabrina; Hämmerle, Martin; Klonner, Carolin; Höfle, Bernhard

    2016-01-01

    The integration of local agricultural knowledge deepens the understanding of complex phenomena such as the association between climate variability, crop yields and undernutrition. Participatory Sensing (PS) is a concept which enables laymen to easily gather geodata with standard low-cost mobile devices, offering new and efficient opportunities for agricultural monitoring. This study presents a methodological approach for crop height assessment based on PS. In-field crop height variations of a maize field in Heidelberg, Germany, are gathered with smartphones and handheld GPS devices by 19 participants. The comparison of crop height values measured by the participants to reference data based on terrestrial laser scanning (TLS) results in R2 = 0.63 for the handheld GPS devices and R2 = 0.24 for the smartphone-based approach. RMSE for the comparison between crop height models (CHM) derived from PS and TLS data is 10.45 cm (GPS devices) and 14.69 cm (smartphones). Furthermore, the results indicate that incorporating participants' cognitive abilities in the data collection process potentially improves the quality data captured with the PS approach. The proposed PS methods serve as a fundament to collect agricultural parameters on field-level by incorporating local people. Combined with other methods such as remote sensing, PS opens new perspectives to support agricultural development.

  12. On-line fast response device and method for measuring dissolved gas in a fluid

    Tutu, Narinder Kumar [Manorville, NY

    2011-01-11

    A method and device for the measurement of dissolved gas within a fluid. The fluid, substantially a liquid, is pumped into a pipe. The flow of the fluid is temporally restricted, creating one or more low pressure regions. A measurement indicative of trapped air is taken before and after the restriction. The amount of dissolved air is calculated from the difference between the first and second measurements. Preferably measurements indicative of trapped air is obtained from one or more pressure transducers, capacitance transducers, or combinations thereof. In the alternative, other methods such as those utilizing x-rays or gamma rays may also be used to detect trapped air. Preferably, the fluid is a hydraulic fluid, whereby dissolved air in the fluid is detected.

  13. Time-resolved ultraviolet near-field scanning optical microscope for characterizing photoluminescence lifetime of light-emitting devices.

    Park, Kyoung-Duck; Jeong, Hyun; Kim, Yong Hwan; Yim, Sang-Youp; Lee, Hong Seok; Suh, Eun-Kyung; Jeong, Mun Seok

    2013-03-01

    We developed a instrument consisting of an ultraviolet (UV) near-field scanning optical microscope (NSOM) combined with time-correlated single photon counting, which allows efficient observation of temporal dynamics of near-field photoluminescence (PL) down to the sub-wavelength scale. The developed time-resolved UV NSOM system showed a spatial resolution of 110 nm and a temporal resolution of 130 ps in the optical signal. The proposed microscope system was successfully demonstrated by characterizing the near-field PL lifetime of InGaN/GaN multiple quantum wells.

  14. Qualification of the on-line power determination of fuel elements in irradiation devices in the BR2 reactor

    Vermeeren, L.; Dekeyser, J.; Gouat, P.; Kalcheva, S.; Koonen, E.; Kuzminov, V.; Verwimp, A.; Weber, M.

    2005-01-01

    Fuel irradiation tests require an on-line monitoring of the fuel power. In the BR2 reactor, this is performed by continuously measuring the enthalpy change in the coolant of the irradiation device and complementing this information with data on power losses, heating of structure parts and spatial power profiles from mock-up test experiments and from calculations. Since a few years Monte Carlo codes (MCNP) are used, describing the BR2 core in great detail for every reactor cycle with its specific core load, yielding not only reliable relative values, but also calculated absolute local power values in agreement with data from PIE analyses. Several methods were conceived to combine the experimental and calculated data for the on-line calculation of the local linear power in the fuel elements; their internal consistency and the consistency with gamma spectroscopy data and data from radiochemical fission product analysis was checked. The data show that fuel irradiations in BR2 can be performed in a well-controlled way, with an accurate and reliable on-line follow-up of the fuel power. (author)

  15. Flow injection microfluidic device with on-line fluorescent derivatization for the determination of Cr(III) and Cr(VI) in water samples after solid phase extraction

    Peng, Guilong [Key Laboratory of Eco-Environment of Three Gorges Region of Ministry of Education, Chongqing University, Chongqing, 400045 (China); Department of Chemistry, Beijing Key Laboratory of Microanalytical Methods and Instrumentation, Tsinghua University, Beijing, 100084 (China); He, Qiang, E-mail: heqiang0980@163.com [Key Laboratory of Eco-Environment of Three Gorges Region of Ministry of Education, Chongqing University, Chongqing, 400045 (China); Lu, Ying [Department of Mathematics and Physics, Armed Police College, Chengdu, 610213 (China); Huang, Jing [Research Center for Advanced Computation, College of Science, Xihua University, Chengdu, 610039 (China); Lin, Jin-Ming, E-mail: jmlin@mail.tsinghua.edu.cn [Department of Chemistry, Beijing Key Laboratory of Microanalytical Methods and Instrumentation, Tsinghua University, Beijing, 100084 (China)

    2017-02-22

    In this paper, a rapid and simple method using magnetic multi-walled carbon nanotubes (MWCNTS), as a solid-phase extraction (SPE) sorbent, was successfully developed for extraction and preconcentration trace amounts of Cr(III) in water samples. The synthesized magnetic-MWCNTs nanocomposite was characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), Fourier transform infrared spectroscopy (FT-IR), X-ray photoelectron spectroscopy (XPS) and X-ray diffraction (XRD). A rhodamine derivative (R1) was synthesized and characterized as a highly selective and sensitive fluorescent derivatizing agent for Cr(III). After SPE procedure, Cr(III) analysis was performed by flow injection microfluidic chip with on-line fluorescent derivatization and laser-induced fluorescence (LIF) spectroscopy detection. The parameters, which affected the efficiency of the developed method were investigated and optimized. Under the optimized conditions, the method exhibited a linear dynamic range of 0–10.0 nM, with a detection limit of 0.094 nM and an enrichment factor of 38. Furthermore, real water samples were analyzed and good recoveries were obtained from 91.0 to 101.6%. - Graphical abstract: Flow injection microfluidic device with on-line fluorescent derivatization and detection coupled to LIF. - Highlights: • A highly selective and sensitive derivatizing reagent for Cr(III) was synthesized and characterized. • The magnetic-MWCNTs nanocomposite as a SPE sorbent was successfully synthesized and characterized. • A new portable detection system was developed for microfluidic chip FIA platform.

  16. Development of a method of absorbed dose on-line monitoring at product processing by scanned electron beam

    Pomatsalyuk, R.I.; Shevchenko, V.A.; Tenishev, A.Eh.; Titov, D.V.; Uvarov, V.L.

    2016-01-01

    The conditions of the contact-free absorbed dose monitoring at industrial product processing by electron beam are investigated. The method is based on analysing the collected charge in a stack monitor (SM) mounted down-stream of irradiated object. Using computer simulation on the basis of a modified transport code PENELOPE-2008, it is shown that by placing a filter of low-energy electrons before SM it is possible to obtain the one-to-one correlation dependence between the monitor charge and absorbed energy of radiation in the processed object. At a certain surface density of the filter, this dependence takes on the form similar to linear. The possibility to use an air gap between the object and SM as such a filter has been demonstrated. For the conditions of radiation plant with an electron accelerator LU-10 of NSC KIPT, the optimum distance of the SM location has been established. For the practical range of the electron energy, beam scan width and surface density of the irradiated product, the constants of ''product absorbed energy-to- SM charge '' linear dependence have been determined. The capability to establish the average absorbed dose in the object moving trough the irradiation zone on the SM current is shown. The calculation data are in satisfactory agreement with the results of measurements.

  17. Expansion of Smartwatch Touch Interface from Touchscreen to Around Device Interface Using Infrared Line Image Sensors

    Soo-Chul Lim

    2015-07-01

    Full Text Available Touchscreen interaction has become a fundamental means of controlling mobile phones and smartwatches. However, the small form factor of a smartwatch limits the available interactive surface area. To overcome this limitation, we propose the expansion of the touch region of the screen to the back of the user’s hand. We developed a touch module for sensing the touched finger position on the back of the hand using infrared (IR line image sensors, based on the calibrated IR intensity and the maximum intensity region of an IR array. For complete touch-sensing solution, a gyroscope installed in the smartwatch is used to read the wrist gestures. The gyroscope incorporates a dynamic time warping gesture recognition algorithm for eliminating unintended touch inputs during the free motion of the wrist while wearing the smartwatch. The prototype of the developed sensing module was implemented in a commercial smartwatch, and it was confirmed that the sensed positional information of the finger when it was used to touch the back of the hand could be used to control the smartwatch graphical user interface. Our system not only affords a novel experience for smartwatch users, but also provides a basis for developing other useful interfaces.

  18. Expansion of Smartwatch Touch Interface from Touchscreen to Around Device Interface Using Infrared Line Image Sensors.

    Lim, Soo-Chul; Shin, Jungsoon; Kim, Seung-Chan; Park, Joonah

    2015-07-09

    Touchscreen interaction has become a fundamental means of controlling mobile phones and smartwatches. However, the small form factor of a smartwatch limits the available interactive surface area. To overcome this limitation, we propose the expansion of the touch region of the screen to the back of the user's hand. We developed a touch module for sensing the touched finger position on the back of the hand using infrared (IR) line image sensors, based on the calibrated IR intensity and the maximum intensity region of an IR array. For complete touch-sensing solution, a gyroscope installed in the smartwatch is used to read the wrist gestures. The gyroscope incorporates a dynamic time warping gesture recognition algorithm for eliminating unintended touch inputs during the free motion of the wrist while wearing the smartwatch. The prototype of the developed sensing module was implemented in a commercial smartwatch, and it was confirmed that the sensed positional information of the finger when it was used to touch the back of the hand could be used to control the smartwatch graphical user interface. Our system not only affords a novel experience for smartwatch users, but also provides a basis for developing other useful interfaces.

  19. Expansion of Smartwatch Touch Interface from Touchscreen to Around Device Interface Using Infrared Line Image Sensors

    Lim, Soo-Chul; Shin, Jungsoon; Kim, Seung-Chan; Park, Joonah

    2015-01-01

    Touchscreen interaction has become a fundamental means of controlling mobile phones and smartwatches. However, the small form factor of a smartwatch limits the available interactive surface area. To overcome this limitation, we propose the expansion of the touch region of the screen to the back of the user’s hand. We developed a touch module for sensing the touched finger position on the back of the hand using infrared (IR) line image sensors, based on the calibrated IR intensity and the maximum intensity region of an IR array. For complete touch-sensing solution, a gyroscope installed in the smartwatch is used to read the wrist gestures. The gyroscope incorporates a dynamic time warping gesture recognition algorithm for eliminating unintended touch inputs during the free motion of the wrist while wearing the smartwatch. The prototype of the developed sensing module was implemented in a commercial smartwatch, and it was confirmed that the sensed positional information of the finger when it was used to touch the back of the hand could be used to control the smartwatch graphical user interface. Our system not only affords a novel experience for smartwatch users, but also provides a basis for developing other useful interfaces. PMID:26184202

  20. In vitro evaluation of photon and raster-scanned carbon ion radiotherapy in combination with gemcitabine in pancreatic cancer cell lines

    Shafie, Rami A. El; Habermehl, Daniel; Rieken, Stefan

    2013-01-01

    Pancreatic cancer is the fourth leading cause of cancer deaths, being responsible for 6% of all cancer-related deaths. Conventional radiotherapy with or without additional chemotherapy has been applied in the past in the context of neoadjuvant or adjuvant therapy concepts with only modest results, however new radiation modalities, such as particle therapy with promising physical and biological characteristics, present an alternative treatment option for patients with pancreatic cancer. Up until now the raster scanning technique employed at our institution for the application of carbon ions has been unique, and no radiobiological data using pancreatic cancer cells has been available yet. The aim of this study was to evaluate cytotoxic effects that can be achieved by treating pancreatic cancer cell lines with combinations of X-rays and gemcitabine, or alternatively with carbon ion irradiation and gemcitabine, respectively. Human pancreatic cancer cell lines AsPC-1, BxPC-3 and Panc-1 were irradiated with photons and carbon ions at various doses and treated with gemcitabine. Photon irradiation was applied with a biological cabin X-ray irradiator, and carbon ion irradiation was applied with an extended Bragg peak (linear energy transfer (LET) 103 keV/μm) using the raster scanning technique at the Heidelberg Ion Therapy Center (HIT). Responsiveness of pancreatic cancer cells to the treatment was measured by clonogenic survival. Clonogenic survival curves were then compared to predicted curves that were calculated employing the local effect model (LEM). Cell survival curves were calculated from the surviving fractions of each combination experiment and compared to a drug control that was only irradiated with X-rays or carbon ions, without application of gemcitabine. In terms of cytotoxicity, additive effects were achieved for the cell lines Panc-1 and BxPC-3, and a slight radiosensitizing effect was observed for AsPC-1. Relative biological effectiveness (RBE) of carbon

  1. On-Line Junction Temperature Monitoring of Switching Devices with Dynamic Compact Thermal Models Extracted with Model Order Reduction

    Fabio Di Napoli

    2017-02-01

    Full Text Available Residual lifetime estimation has gained a key point among the techniques that improve the reliability and the efficiency of power converters. The main cause of failures are the junction temperature cycles exhibited by switching devices during their normal operation; therefore, reliable power converter lifetime estimation requires the knowledge of the junction temperature time profile. Since on-line dynamic temperature measurements are extremely difficult, in this work an innovative real-time monitoring strategy is proposed, which is capable of estimating the junction temperature profile from the measurement of the dissipated powers through an accurate and compact thermal model of the whole power module. The equations of this model can be easily implemented inside a FPGA, exploiting the control architecture already present in modern power converters. Experimental results on an IGBT power module demonstrate the reliability of the proposed method.

  2. IE Information Notice No. 85-64: BBC Brown Boveri low-voltage K-line circuit breakers, with deficient overcurrent trip devices models OD-4 and 5

    Jordan, E.L.

    1992-01-01

    On May 13, 1985, BBC Brown Boveri Inc. (BBC) made a 10 CFR Part 21 report to the NRC concerning a deficiency in the Models OD-4 and OD-5 overcurrent trip devices installed on K-line circuit breakers. The affected breakers were manufactured by BBC from October 1983 to March 1985 and may have incorrect short time delay band levers (links) installed in electromechanical overcurrent trip device models OD-4 and OD-5. The incorrect link could limit the travel of the short time armature and cause the short time element to be inoperative in the maximum (MAX) band. The May 13, 1985, report recommended that all K-line circuit breakers with the OD-4 and OD-5 overcurrent trip devices and any spare OD-4 and OD-5 overcurrent trip devices that were manufactured between October 1983 and March 1985, be inspected for an incorrect short time delay band link. Licensees known by BBC to have purchased K-line breakers or spare OD-4 or OD-5 overcurrent trip devices were notified of the possible defect and instructions provided for their inspection. Enclosed is a list of utilities and related facilities that were notified by BBC. However, BBC advised the NRC that there is a possibility that other utilities could be using K-line circuit breakers with the suspect OD-4 and OD-5 overcurrent trip devices. Therefore, all licensees are being notified of this possible defect

  3. The relative biological effectiveness for carbon and oxygen ion beams using the raster-scanning technique in hepatocellular carcinoma cell lines.

    Daniel Habermehl

    Full Text Available BACKGROUND: Aim of this study was to evaluate the relative biological effectiveness (RBE of carbon (12C and oxygen ion (16O-irradiation applied in the raster-scanning technique at the Heidelberg Ion beam Therapy center (HIT based on clonogenic survival in hepatocellular carcinoma cell lines compared to photon irradiation. METHODS: Four human HCC lines Hep3B, PLC, HepG2 and HUH7 were irradiated with photons, 12C and 16O using a customized experimental setting at HIT for in-vitro trials. Cells were irradiated with increasing physical photon single doses of 0, 2, 4 and 6 Gy and heavy ion-single doses of 0, 0.125, 0.5, 1, 2, 3 Gy (12C and 16O. SOBP-penetration depth and extension was 35 mm +/-4 mm and 36 mm +/-5 mm for carbon ions and oxygen ions respectively. Mean energy level and mean linear energy transfer (LET were 130 MeV/u and 112 keV/um for 12C, and 154 MeV/u and 146 keV/um for 16O. Clonogenic survival was computated and relative biological effectiveness (RBE values were defined. RESULTS: For all cell lines and both particle modalities α- and β-values were determined. As expected, α-values were significantly higher for 12C and 16O than for photons, reflecting a steeper decline of the initial slope of the survival curves for high-LET beams. RBE-values were in the range of 2.1-3.3 and 1.9-3.1 for 12C and 16O, respectively. CONCLUSION: Both irradiation with 12C and 16O using the raster-scanning technique leads to an enhanced RBE in HCC cell lines. No relevant differences between achieved RBE-values for 12C and 16O were found. Results of this work will further influence biological-adapted treatment planning for HCC patients that will undergo particle therapy with 12C or 16O.

  4. Three-dimensional fabric analysis for anisotropic material using multi-directional scanning line. Application to x-ray CI image

    Takemura, Takato; Takahashi, Manabu; Oda, Masanobu; Hirai, Hidekazu; Murakoshi, Atsushi; Miura, Makoto

    2007-01-01

    In microscopic analysis, materials are characterized by a three-dimensional (3D) microstructure which is composed of constituent elements such as pores, voids and cracks. A material's mechanical and hydrological properties are strongly dependent on its microstructure. In order to discuss the mechanics of geomaterials on a microstructural level, detailed information on their 3D macrostructure is required. X-ray computed tomography is a powerful non-destructive method for determining the microstructure, however it can be difficult to determine a material's microstructure from the reconstructed 3D image. We successfully evaluated the 3D microstructural anisotropy of porous and fibrous materials using a multi-directional scanning line method that employs straightforward image analysis, and its results were visualized using stereonet projection. (author)

  5. SU-C-207A-06: On-Line Beam Range Verification with Multiple Scanning Particle Beams: Initial Feasibility Study with Simulations

    Zhong, Y; Sun, X; Lu, W; Jia, X; Wang, J; Shao, Y [The University of Texas Southwestern Medical Ctr., Dallas, TX (United States)

    2016-06-15

    Purpose: To investigate the feasibility and requirement for intra-fraction on-line multiple scanning particle beam range verifications (BRVs) with in-situ PET imaging, which is beyond the current single-beam BRV with extra factors that will affect the BR measurement accuracy, such as beam diameter, separation between beams, and different image counts at different BRV positions. Methods: We simulated a 110-MeV proton beam with 5-mm diameter irradiating a uniform PMMA phantom by GATE simulation, which generated nuclear interaction-induced positrons. In this preliminary study, we simply duplicated these positrons and placed them next to the initial protons to approximately mimic the two spatially separated positron distributions produced by two beams parallel to each other but with different beam ranges. These positrons were then imaged by a PET (∼2-mm resolution, 10% sensitivity, 320×320×128 mm^3 FOV) with different acquisition times. We calculated the positron activity ranges (ARs) from reconstructed PET images and compared them with the corresponding ARs of original positron distributions. Results: Without further image data processing and correction, the preliminary study show the errors between the measured and original ARs varied from 0.2 mm to 2.3 mm as center-to-center separations and range differences were in the range of 8–12 mm and 2–8 mm respectively, indicating the accuracy of AR measurement strongly depends on the beam separations and range differences. In addition, it is feasible to achieve ≤ 1.0-mm accuracy for both beams with 1-min PET acquisition and 12 mm beam separation. Conclusion: This study shows that the overlap between the positron distributions from multiple scanning beams can significantly impact the accuracy of BRVs of distributed particle beams and need to be further addressed beyond the established method of single-beam BRV, but it also indicates the feasibility to achieve accurate on-line multi-beam BRV with further improved

  6. Direct observation of interlayer Josephson vortices in heavily Pb-doped Bi2Sr2CaCu2Oy by scanning superconducting quantum interference device microscopy

    Kasai, Junpei; Hasegawa, Tetsuya; Okazaki, Noriaki; Koinuma, Hideomi; Nakayama, Yuri; Shimoyama, Jun-ichi; Kishio, Kohji; Motohashi, Teruki; Matsumoto, Yuji

    2006-01-01

    Josephson vortices trapped in cross-sectional edge surfaces of Pb 0.6 Bi 1.4 Sr 2 CaCu 2 O y has been directly observed by using a scanning superconducting quantum interference device (SQUID) microscope. The magnetic field distribution B z around each vortex is substantially anisotropic, compared with the usual vortex in the ab-plane, and is extended over 100 μm toward the in-plane direction. By fitting a theoretical B z function to experimental ones, c-axis penetration depth λ c was estimated to be 11.2 ±0.7 μm, which is in good agreement with the literature value, 12.6 μm, obtained from the Josephson plasma edge frequency. (author)

  7. Probing the limits of Si:P δ-doped devices patterned by a scanning tunneling microscope in a field-emission mode

    Rudolph, M.; Carr, S. M.; Ten Eyck, G.; Dominguez, J.; Carroll, M. S.; Bussmann, E. [Sandia National Laboratories, Albuquerque, New Mexico 87185 (United States); Subramania, G. [Sandia National Laboratories, Albuquerque, New Mexico 87185 (United States); Department of Electrical and Computer Engineering, University of New Mexico, Albuquerque, New Mexico 87131 (United States); Lilly, M. P. [Sandia National Laboratories, Albuquerque, New Mexico 87185 (United States); Center for Integrated Nanotechnologies, Sandia National Laboratories, Albuquerque, New Mexico 87185 (United States); Pluym, T.

    2014-10-20

    Recently, a single atom transistor was deterministically fabricated using phosphorus in Si by H-desorption lithography with a scanning tunneling microscope (STM). This milestone in precision, achieved by operating the STM in the conventional tunneling mode, typically utilizes slow (∼10{sup 2} nm{sup 2}/s) patterning speeds. By contrast, using the STM in a high-voltage (>10 V) field-emission mode, patterning speeds can be increased by orders of magnitude to ≳10{sup 4} nm{sup 2}/s. We show that the rapid patterning negligibly affects the functionality of relatively large micron-sized features, which act as contacting pads for these devices. For nanoscale structures, we show that the resulting electrical transport is consistent with the donor incorporation chemistry constraining the electrical dimensions to a scale of 10 nm even though the pattering spot size is 40 nm.

  8. Contribution to the study and realization of a gamma scanning examination method for irradiation devices analysis in a research nuclear reactor

    Michel, Francois.

    1979-01-01

    To meet the requirements of the experimenters in research nuclear reactors, a fast quantitative, non destructive method of irradiation devices examination was conceived and applied in the CEN.G SILOE reactor as far back as 1972. The object is the analysis of the fuel sample evolution and the continuous study of the possible coolant contamination. This report describes and justifies the choices taken for the measurements installation conception (two dimensional scanning bench, collimation, detector, automatic operation), and explains the analysis and calibration methods, the work on the whole being adjusted to obtain absolute results (present atomic concentrations). Different results interpretations are presented which concern the axial and radial fission products migration in the fuel, their release in case of cladding rupture, and the fission power measurement [fr

  9. SU-F-T-138: Commissioning and Evaluating Dose Computation Models for a Dedicated Proton Line Scanning Beam Nozzle in Eclipse Treatment Planning System

    Tsai, P [Chang Gung Memorial Hospital, Proton and Radiation Therapy Center, Tao-yuan, Taiwan (China); Chang Gung University, Taoyuan, Taiwan (China); Huang, H; Cai, S; Chen, H; Wu, S; Wu, T; Lee, S; Yeh, C; Wu, T [Chang Gung Memorial Hospital, Proton and Radiation Therapy Center, Tao-yuan, Taiwan (China); Lee, C [Chang Gung University, Taoyuan, Taiwan (China)

    2016-06-15

    Purpose: In this study, we present an effective method to derive low dose envelope of the proton in-air spot fluence at beam positions other than the isocenter to reduce amount of measurements required for planning commission. Also, we demonstrate commissioning and validation results of this method to the Eclipse treatment planning system (version 13.0.29) for a Sumitomo dedicated proton line scanning beam nozzle. Methods: The in-air spot profiles at five beam-axis positions (±200, ±100 and 0 mm) were obtained in trigger mode using a MP3 Water tank (PTW-Freiburg) and a pinpoint ionization chamber (model 31014, PTW-Freiburg). Low dose envelope (below 1% of the center dose) of the spot profile at isocenter was obtained by repeated point measurements to minimize dosimetry uncertainty. The double Gaussian (DG) model was used to fit and obtain optimal σ1, σ2 and their corresponding weightings through our in-house MATLAB (Mathworks) program. σ1, σ2 were assumed to expand linearly along the beam axis from a virtual source position calculated by back projecting fitted sigmas from the single Gaussian (SG) model. Absolute doses in water were validated using an Advanced Markus chamber at the depth of 2cm with Pristine Peak (BP) R90d ranging from 5–32 cm for 10×10 cm2 scanned fields. The field size factors were verified with square fields from 2 to 20 cm at 2cm and before BP depth. Results: The absolute dose outputs were found to be within ±3%. For field size factor, the agreement between calculated and measurement were within ±2% at 2cm and ±3% before BP, except for the field size below 2×2 cm2. Conclusion: The double Gaussian model was found to be sufficient for characterizing the Sumitomo dedicated proton line scanning nozzle. With our effective double Gaussian fitting method, we are able to save significant proton beam time with acceptable output accuracy.

  10. Scanning holograms

    Natali, S.

    1984-01-01

    This chapter reports on the scanning of 1000 holograms taken in HOBC at CERN. Each hologram is triggered by an interaction in the chamber, the primary particles being pions at 340 GeV/c. The aim of the experiment is the study of charm production. The holograms, recorded on 50 mm film with the ''in line'' technique, can be analyzed by shining a parallel expanded laser beam through the film, obtaining immediately above it the real image of the chamber which can then be scanned and measured with a technique half way between emulsions and bubble chambers. The results indicate that holograms can be analyzed as quickly and reliably as in other visual techniques and that to them is open the same order of magnitude of large scale experiments

  11. Neon-like Iron Ion Lines Measured in NIFS/Large Helical Device (LHD) and Hinode/EUV Imaging Spectrometer (EIS)

    Watanabe, Tetsuya; Hara, Hirohisa; Murakami, Izumi; Kato, Daiji; Sakaue, Hiroyuki A.; Morita, Shigeru; Suzuki, Chihiro; Tamura, Naoki; Yamamoto, Norimasa; Nakamura, Nobuyuki

    2017-06-01

    Line intensities emerging from the Ne-sequence iron ion (Fe XVII) are measured in the laboratory, by the Large Helical Device at the National Institute for Fusion Science, and in the solar corona by the EUV Imaging Spectrometer (EIS) on board the Hinode mission. The intensity ratios of Fe XVII λ 204.6/λ 254.8 are derived in the laboratory by unblending the contributions of the Fe XIII and XII line intensities. They are consistent with theoretical predictions and solar observations, the latter of which endorses the in-flight radiometric calibrations of the EIS instrument. The still remaining temperature-dependent behavior of the line ratio suggests the contamination of lower-temperature iron lines that are blended with the λ 204.6 line.

  12. The neural elements in the lining of the ventricular-subventricular zone: making an old story new by high-resolution scanning electron microscopy

    Carlos Alexandre Dos Santos Haemmerle

    2015-10-01

    Full Text Available The classical description of the neural elements that compose the lining of brain ventricles introduces us to the single layer of ependymal cells. However, new findings, especially in the lateral ventricle - the major niche for the generation of new neurons in the adult brain - have provided information about additional cell elements that influence the organization of this part of the ventricular system and produce important contributions to neurogenesis. To complement the cell neurochemistry findings, we present a three-dimensional in situ description that demonstrates the anatomical details of the different types of ciliated cells and the innervation of these elements. After processing adult rat brains for ultrastructural analysis by high-resolution scanning electron microscopy and transmission electron microscopy, we observed a heterogeneous pattern of cilia distribution at the different poles of the lateral ventricle surface. Furthermore, we describe the particular three-dimensional aspects of the ciliated cells of the lateral ventricle, in addition the fiber bundles and varicose axons surrounding these cells. Therefore, we provide a unique ultrastructural description of the three-dimensional in situ organization of the lateral ventricle surface, highlighting its innervation, to corroborate the available neurochemical and functional findings regarding the factors that regulate this neurogenic niche.

  13. Possibilities of LA-ICP-MS technique for the spatial elemental analysis of the recent fish scales: Line scan vs. depth profiling

    Hola, Marketa; Kalvoda, Jiri; Novakova, Hana; Skoda, Radek; Kanicky, Viktor

    2011-01-01

    LA-ICP-MS and solution based ICP-MS in combination with electron microprobe are presented as a method for the determination of the elemental spatial distribution in fish scales which represent an example of a heterogeneous layered bone structure. Two different LA-ICP-MS techniques were tested on recent common carp (Cyprinus carpio) scales: (a)A line scan through the whole fish scale perpendicular to the growth rings. The ablation crater of 55 μm width and 50 μm depth allowed analysis of the elemental distribution in the external layer. Suitable ablation conditions providing a deeper ablation crater gave average values from the external HAP layer and the collagen basal plate. (b)Depth profiling using spot analysis was tested in fish scales for the first time. Spot analysis allows information to be obtained about the depth profile of the elements at the selected position on the sample. The combination of all mentioned laser ablation techniques provides complete information about the elemental distribution in the fish scale samples. The results were compared with the solution based ICP-MS and EMP analyses. The fact that the results of depth profiling are in a good agreement both with EMP and PIXE results and, with the assumed ways of incorporation of the studied elements in the HAP structure, suggests a very good potential for this method.

  14. Possibilities of LA-ICP-MS technique for the spatial elemental analysis of the recent fish scales: Line scan vs. depth profiling

    Hola, Marketa [Department of Chemistry, Masaryk University of Brno, Kamenice 5, 625 00 Brno (Czech Republic); Kalvoda, Jiri, E-mail: jkalvoda@centrum.cz [Department of Geological Sciences, Masaryk University of Brno, Kotlarska 2, 611 37 Brno (Czech Republic); Novakova, Hana [Department of Chemistry, Masaryk University of Brno, Kamenice 5, 625 00 Brno (Czech Republic); Skoda, Radek [Department of Geological Sciences, Masaryk University of Brno, Kotlarska 2, 611 37 Brno (Czech Republic); Kanicky, Viktor [Department of Chemistry, Masaryk University of Brno, Kamenice 5, 625 00 Brno (Czech Republic)

    2011-01-01

    LA-ICP-MS and solution based ICP-MS in combination with electron microprobe are presented as a method for the determination of the elemental spatial distribution in fish scales which represent an example of a heterogeneous layered bone structure. Two different LA-ICP-MS techniques were tested on recent common carp (Cyprinus carpio) scales: (a)A line scan through the whole fish scale perpendicular to the growth rings. The ablation crater of 55 {mu}m width and 50 {mu}m depth allowed analysis of the elemental distribution in the external layer. Suitable ablation conditions providing a deeper ablation crater gave average values from the external HAP layer and the collagen basal plate. (b)Depth profiling using spot analysis was tested in fish scales for the first time. Spot analysis allows information to be obtained about the depth profile of the elements at the selected position on the sample. The combination of all mentioned laser ablation techniques provides complete information about the elemental distribution in the fish scale samples. The results were compared with the solution based ICP-MS and EMP analyses. The fact that the results of depth profiling are in a good agreement both with EMP and PIXE results and, with the assumed ways of incorporation of the studied elements in the HAP structure, suggests a very good potential for this method.

  15. Impact of line edge roughness on the performance of 14-nm FinFET: Device-circuit Co-design

    Rathore, Rituraj Singh; Rana, Ashwani K.

    2018-01-01

    With the evolution of sub-20 nm FinFET technology, line edge roughness (LER) has been identified as a critical problem and may result in critical device parameter variation and performance limitation in the future VLSI circuit application. In the present work, an analytical model of fin-LER has been presented, which shows the impact of correlated and uncorrelated LER on FinFET structure. Further, the influence of correlated and uncorrelated fin- LER on all electrical performance parameters is thoroughly investigated using the three-dimensional (3-D) Technology Computer Aided Design (TCAD) simulations for 14-nm technology node. Moreover, the impact of all possible fin shapes on threshold voltage (VTH), drain induced barrier lowering (DIBL), on-current (ION), and off-current (IOFF) has been compared with the well calibrated rectangular FinFET structure. In addition, the influence of all possible fin geometries on the read stability of six-transistor (6-T) Static-Random-Access-Memory (SRAM) has been investigated. The study reveals that fin-LER plays a vital role as it directly governs the electrostatics of the FinFET structure. This has been found that there is a high degree of fluctuations in all performance parameters for uncorrelated fin-LER type FinFETs as compared to correlated fin-LER with respect to rectangular FinFET structure. This paper gives physical insight of FinFET design, especially in sub-20 nm technology nodes by concluding that the impact of LER on electrical parameters are minimum for correlated LER.

  16. An Energy-Saving Concept of the Smart Building Power Grid with Separated Lines for Standby Devices

    Dmytro Zubov

    2016-09-01

    Full Text Available Standby power takes 5-10 % of the residential electricity around the world. Some countries lose more than 14 % of the total electricity used in the residential sector. Hence, a new energysaving concept that could help to decrease the power losses is discussed in this paper. Firstly, the two power lines of infrastructure for continuously connected equipment and for standby devices is proposed for new smart buildings. Secondly, the segmented infrastructure with unified hardwareunits is proposed for existing smart buildings (the new one can apply this principle as well. The contactors (i.e. unified hardware units consist of the NodeMcu Lua ESP8266 WiFi IoTdevelopment board, ACS712T ELC-30A current sensor, and the Songle relay. The automatic mode is based on three steps: measurement of the current using ACS712T ELC-30A sensor in all segments except the root; switching off the relays with the current less than or equal to any number in the historical data; switching off the root contactor if all the descendent relays (i.e. contactors are switched off. Second step represents the linear classification with sliding window in machine learning. The software consists of two parts, low-level Arduino sketches and high-level C# Windows form app. They are connected by MQTT broker Mosquitto. The proposed concept was successfully tested using a prototype with three segments, one of which includes smart lighting. The payback period is of approximately one month and a half for the whole-building switch concept.

  17. Thyroid Scan and Uptake

    Full Text Available ... Because nuclear medicine procedures are able to pinpoint molecular activity within the body, they offer the potential ... or imaging device that produces pictures and provides molecular information. The thyroid scan and thyroid uptake provide ...

  18. A new laryngeal mask supraglottic airway device with integrated balloon line: a descriptive and comparative bench study

    Zhou YH

    2016-11-01

    Full Text Available YingHai Zhou,1 Korinne Jew2 1Research & Development, Patient Monitoring & Recovery, Medtronic Technology Center, Shanghai, People’s Republic of China; 2Medical Affairs, Minimally Invasive Therapies Group, Medtronic, Boulder, CO, USA Abstract: Laryngeal masks are invasive devices for airway management placed in the supraglottic position. The Shiley™ laryngeal mask (Shiley™ LM features an integrated inflation tube and airway shaft to facilitate product insertion and reduce the chance of tube occlusion when patients bite down. This study compared the Shiley LM to two other disposable laryngeal mask devices, the Ambu® AuraStraight™ and the LMA Unique™. Overall device design, tensile strength, flexibility of various structures, and sealing performance were measured. The Shiley LM is structurally stronger and its shaft is more resistant to compression than the other devices. The Shiley LM is generally less flexible than the other devices, but this relationship varies with device size. Sealing performance of the devices was similar in a bench assay. The results of this bench study demonstrate that the new Shiley LM resembles other commercially available laryngeal mask devices, though it exhibits greater tensile strength and lower flexibility. Keywords: laryngeal mask, supraglottic airway, supralaryngeal device

  19. Online measuring devices at sewage treatment plants - state of the art and future market potential; On-Line-Messtechnik auf Klaeranlagen - Aktueller Stand und Marktpotential fuer die Zukunft

    Baumann, P [Inst. fuer Siedlungswasserbau, Wasserguete- und Abfallwirtschaft der Univ. Stuttgart, Abt. Abwassertechnik (Germany); Schlegel, S [Emschergenossenschaft, Essen (Germany)

    1998-12-31

    By means of a survey commissioned by ATV/GFA, the purposes of use and spheres of use as well as the operating experience with online measuring devices for the determination of ammonium, oxidized nitrogen compounds and orthophosphate were established and evaluated. In addition, data were acquired with the aid of other units for the continuous recording of chemical and physical parameters of sewage treatment. Finally, the future market potentials and development pospects of online measuring devices were evaluated. (orig.) [Deutsch] Anhand einer im Auftrag der ATV/GFA durchgefuehrten Umfrage wurden Einsatzzweck, Einsatzbereiche und Betriebserfahrungen von On-line-Messgeraeten zur Bestimmung von Ammonium, oxidierten Stickstoffverbindungen und Orthophosphat dargestellt und bewertet. Zusaetzlich wurden auch Daten von anderen Geraeteeinheiten zur kontinuierlichen Erfassung von chemischen und physikalischen Parametern bei der Abwasserreinigung erhoben. Anschliessend wurde das zukuenftige Marktpotential und die Entwicklungsmoeglichkeiten bei der On-line-Messtechnik bewertet. (orig.)

  20. Online measuring devices at sewage treatment plants - state of the art and future market potential; On-Line-Messtechnik auf Klaeranlagen - Aktueller Stand und Marktpotential fuer die Zukunft

    Baumann, P. [Inst. fuer Siedlungswasserbau, Wasserguete- und Abfallwirtschaft der Univ. Stuttgart, Abt. Abwassertechnik (Germany); Schlegel, S. [Emschergenossenschaft, Essen (Germany)

    1997-12-31

    By means of a survey commissioned by ATV/GFA, the purposes of use and spheres of use as well as the operating experience with online measuring devices for the determination of ammonium, oxidized nitrogen compounds and orthophosphate were established and evaluated. In addition, data were acquired with the aid of other units for the continuous recording of chemical and physical parameters of sewage treatment. Finally, the future market potentials and development pospects of online measuring devices were evaluated. (orig.) [Deutsch] Anhand einer im Auftrag der ATV/GFA durchgefuehrten Umfrage wurden Einsatzzweck, Einsatzbereiche und Betriebserfahrungen von On-line-Messgeraeten zur Bestimmung von Ammonium, oxidierten Stickstoffverbindungen und Orthophosphat dargestellt und bewertet. Zusaetzlich wurden auch Daten von anderen Geraeteeinheiten zur kontinuierlichen Erfassung von chemischen und physikalischen Parametern bei der Abwasserreinigung erhoben. Anschliessend wurde das zukuenftige Marktpotential und die Entwicklungsmoeglichkeiten bei der On-line-Messtechnik bewertet. (orig.)

  1. Thyroid Scan and Uptake

    Full Text Available ... found, and should not be a cause of concern for you. If you had an intravenous line ... found, and should not be a cause of concern for you. Actual scanning time for each thyroid ...

  2. The challenges encountered in the integration of an early test wafer surface scanning inspection system into a 450mm manufacturing line

    Lee, Jeffrey; McGarvey, Steve

    2013-04-01

    The introduction of early test wafer (ETW) 450mm Surface Scanning Inspection Systems (SSIS) into Si manufacturing has brought with it numerous technical, commercial, and logistical challenges on the path to rapid recipe development and subsequent qualification of other 450mm wafer processing equipment. This paper will explore the feasibility of eliminating the Polystyrene Latex Sphere deposition process step and the subsequent creation of SSIS recipes based upon the theoretical optical properties of both the SSIS and the process film stack(s). The process of Polystyrene Latex Sphere deposition for SSIS recipe generation and development is generally accepted on the previous technology nodes for 150/200/300mm wafers. PSL is deposited with a commercially available deposition system onto a non-patterned bare Si or non-patterned filmed Si wafer. After deposition of multiple PSL spots, located in different positions on a wafer, the wafer is inspected on a SSIS and a response curve is generated. The response curve is based on the the light scattering intensity of the NIST certified PSL that was deposited on the wafer. As the initial 450mm Si wafer manufacturing began, there were no inspection systems with sub-90nm sensitivities available for defect and haze level verification. The introduction of a 450mm sub-30nm inspection system into the manufacturing line generated instant challenges. Whereas the 450mm wafers were relatively defect free at 90nm, at 40nm the wafers contained several hundred thousand defects. When PSL was deposited onto wafers with these kinds of defect levels, PSL with signals less than the sub-90nm defects were difficult to extract. As the defectivity level of the wafers from the Si suppliers rapidly improves the challenges of SSIS recipe creation with high defectivity decreases while at the same time the cost of PSL deposition increases. The current cost per wafer is fifteen thousand dollars for a 450mm PSL deposition service. When viewed from the

  3. Optimal Scheduling of Material Handling Devices in a PCB Production Line: Problem Formulation and a Polynomial Algorithm

    Ada Che

    2008-01-01

    Full Text Available Modern automated production lines usually use one or multiple computer-controlled robots or hoists for material handling between workstations. A typical application of such lines is an automated electroplating line for processing printed circuit boards (PCBs. In these systems, cyclic production policy is widely used due to large lot size and simplicity of implementation. This paper addresses cyclic scheduling of a multihoist electroplating line with constant processing times. The objective is to minimize the cycle time, or equivalently to maximize the production throughput, for a given number of hoists. We propose a mathematical model and a polynomial algorithm for this scheduling problem. Computational results on randomly generated instances are reported.

  4. Nuclear Scans

    Nuclear scans use radioactive substances to see structures and functions inside your body. They use a special ... images. Most scans take 20 to 45 minutes. Nuclear scans can help doctors diagnose many conditions, including ...

  5. Line voltage distortions due to operation of the power supply devices required for plasma heating and magnetic field generation in the W7X thermonuclear fusion experiment

    Werner, F.

    1997-03-01

    The operation of the W7-X plasma heating devices requires high voltage DC power supplies with a total electrical power of 40 MVA. For this purpose twelve-pulse AC/DC converters are projected. These converters enforce a non sinusoidal line current, whose harmonics are causing corresponding line voltage distortions. To evaluate the extent of these distortions, the reaction of the harmonic currents on the AC line, is investigated by numerical network analysis. This is done for both, the 20 kV-junction point of the converters and the 110 kV-line terminal of the electricity supply company. Furthermore the design of LC series-resonant circuits, projected for power factor correction and damping of the harmonic content of the line voltage, has been verified. The additional operation of the 1.5 MVA magnet power supplies also contributes, even though to a much smaller extent, to the line voltage distortion. The influence of these twelve-pulse AC/DC converters was investigated too. The numerical calculations have been done with the aid of the network simulation program 'Pspice'. In an equivalent circuit the transmission line network and the transformers are represented by their inductances respectively equivalent inductances. The rectifier units are simulated by a number of current sources, producing the current harmonics in amplitude, frequency and phase. The harmonics amplitudes of the plasma heating power supplies are frequency and phase. The harmonics amplitudes of the plasma heating power supplies are measured values given by the manufacturer. For the magnet power supplies, the harmonics are derived from the theoretical step like I(t) current shape by Fourier series decomposition. Due to the action of the LC circuits the achieved characteristic voltage quality values are far below the permissible values corresponding to the recommendations of VDE 0160. (orig.) [de

  6. Diode line scanner for beam diagnostics

    Gustov, S.A.

    1987-01-01

    The device-scanning diode line is described. It is applied for beam profile measuring with space precision better than ± 0.5 mm and with discreteness of 3 mm along Y-axis and 0.25 mm along X-axis. The device is easy in construction, reliable and has a small time of information acquisition (2-5 min). The working range is from 100 to 10 6 rad/min (10 6 -10 10 part/mm 2 /s for 660 MeV protons). Radioresistance is 10 7 rad. The device can be applied for precise beam line element tuning at beam transporting and emittance measuring. The fixed diode line (a simplified device version) has smaller dimensions and smaller time of data acquisition (2-5 s). It is applied for quick preliminary beamline tuning. The flowsheet and different variants of data representation on beam profile are given

  7. Frostbite and bone scanning: the use of 99mTc-labeled phosphates in demarcating the line of viability in frostbite victims

    Ikawa, G.; dos Santos, P.A.; Yamaguchi, K.T.; Stroh-Recor, C.; Ibello, R.

    1986-01-01

    Early diagnosis of the extent of bone and soft tissue damage is a very important step in treating a frostbite victim. The diagnostic use of Tc-99m-phosphates in assessing the viability of soft tissue and bone in frostbite was evaluated in the early post-thaw period. Four patients were treated with a combination of warm baths, rehydration, vasodilators, epidural block, fasciotomy, and debridement. Six scans were done to stage involvement. In three of the four cases, final involvement could be determined as early as the third day. When a specific level of soft tissue or bone uptake was determined, future scanning showed either improvement, or no change in three of the four patients. In our experience, Tc-99m-phosphate scans represent an improvement over other diagnostic tests for viability of tissues

  8. Device of connecting the metal sheet lining a concrete enclosure to a pipe opening inside the enclosure

    Petit, Guy.

    1975-01-01

    Said invention relates to a sealed device connecting a metal sheet anchored on the internal side of a concrete vessel containing a hot pressurized fluid, with a metallic pipe opening inside said vessel. It is intended for heat insulating structures so-called 'hot skin' used for the pressure vessels of some boiling water reactors. Said invention is intended for different types of said pipe such as: the penetrations for the inlets and outlets of the primary circuit, or anchoring cylindrical sheaths used as supports of components or other elements located inside said pressure vessel [fr

  9. In-Line Acoustic Device Inspection of Leakage in Water Distribution Pipes Based on Wavelet and Neural Network

    Dileep Kumar

    2017-01-01

    Full Text Available Traditionally permanent acoustic sensors leak detection techniques have been proven to be very effective in water distribution pipes. However, these methods need long distance deployment and proper position of sensors and cannot be implemented on underground pipelines. An inline-inspection acoustic device is developed which consists of acoustic sensors. The device will travel by the flow of water through the pipes which record all noise events and detect small leaks. However, it records all the noise events regarding background noises, but the time domain noisy acoustic signal cannot manifest complete features such as the leak flow rate which does not distinguish the leak signal and environmental disturbance. This paper presents an algorithm structure with the modularity of wavelet and neural network, which combines the capability of wavelet transform analyzing leakage signals and classification capability of artificial neural networks. This study validates that the time domain is not evident to the complete features regarding noisy leak signals and significance of selection of mother wavelet to extract the noise event features in water distribution pipes. The simulation consequences have shown that an appropriate mother wavelet has been selected and localized to extract the features of the signal with leak noise and background noise, and by neural network implementation, the method improves the classification performance of extracted features.

  10. The use of differential scanning calorimetry for the evaluation of dental materials. I. Cements, cavity lining materials and anterior restorative materials.

    McCabe, J F; Wilson, H J

    1980-03-01

    Thermal changes occurring during the setting of restorative materials have been measured accurately using a differential scanning calorimeter. The results were used to evaluate setting characteristics. The heat of reaction and rate of heat output may be significant in determining thermal damage to the pulp. The heat capacity is related to thermal insulation properties. These properties have been determined and their effect on the efficacy of restorative materials discussed.

  11. Renal scan

    ... this page: //medlineplus.gov/ency/article/003790.htm Renal scan To use the sharing features on this ... anaphylaxis . Alternative Names Renogram; Kidney scan Images Kidney anatomy Kidney - blood and urine flow References Chernecky CC, ...

  12. CT Scan

    ... disease, lung nodules and liver masses Monitor the effectiveness of certain treatments, such as cancer treatment Detect ... scan done in a hospital or an outpatient facility. CT scans are painless and, with newer machines, ...

  13. Measurements of line-averaged electron density of pulsed plasmas using a He-Ne laser interferometer in a magnetized coaxial plasma gun device

    Iwamoto, D.; Sakuma, I.; Kitagawa, Y.; Kikuchi, Y.; Fukumoto, N.; Nagata, M.

    2012-10-01

    In next step of fusion devices such as ITER, lifetime of plasma-facing materials (PFMs) is strongly affected by transient heat and particle loads during type I edge localized modes (ELMs) and disruption. To clarify damage characteristics of the PFMs, transient heat and particle loads have been simulated by using a plasma gun device. We have performed simulation experiments by using a magnetized coaxial plasma gun (MCPG) device at University of Hyogo. The line-averaged electron density measured by a He-Ne interferometer is 2x10^21 m-3 in a drift tube. The plasma velocity measured by a time of flight technique and ion Doppler spectrometer was 70 km/s, corresponding to the ion energy of 100 eV for helium. Thus, the ion flux density is 1.4x10^26 m-2s-1. On the other hand, the MCPG is connected to a target chamber for material irradiation experiments. It is important to measure plasma parameters in front of target materials in the target chamber. In particular, a vapor cloud layer in front of the target material produced by the pulsed plasma irradiation has to be characterized in order to understand surface damage of PFMs under ELM-like plasma bombardment. In the conference, preliminary results of application of the He-Ne laser interferometer for the above experiment will be shown.

  14. Multichannel scanning spectrophotometer

    Lagutin, A.F.

    1979-01-01

    A spectrophotometer designed in the Crimea astrophysical observatory is described. The spectrophotometer is intended for the installation at the telescope to measure energy distribution in the star spectra in the 3100-8550 A range. The device is made according to the scheme with a fixed diffraction lattice. The choice of the optical kinematic scheme is explained. The main design elements are shown. Some singularities of the scanning drive kinematics are considered. The device performance is given

  15. Device for ray diagnosis for determining the distribution of radioactive substances

    Heinz, L.

    1976-01-01

    A ray diagnosing device for determining the distribution of radioactive substances in a body has a measuring head containing the ray probe, means for moving the head for a scanning line by line of the part to be examined, a setting device for the line distance and a printer actuated by the ray probe for inscribing an image corresponding to the activity distribution upon a writing sheet. The invention is particularly characterized in that the printer has a number of printing keys each of which is made to correspond to a specific line spacing and that there is an adjusting device for selectively switching on and off each one of the keys

  16. IVO, a device for In situ Volatilization and On-line detection of products from heavy ion reactions

    Duellmann, C E; Eichler, R; Gäggeler, H W; Jost, D T; Piguet, D; Türler, A

    2002-01-01

    A new gaschromatographic separation system to rapidly isolate heavy ion reaction products in the form of highly volatile species is described. Reaction products recoiling from the target are stopped in a gas volume and converted in situ to volatile species, which are swept by the carrier gas to a chromatography column. Species that are volatile under the given conditions pass through the column. In a cluster chamber, which is directly attached to the exit of the column, the isolated volatile species are chemically adsorbed to the surface of aerosol particles and transported to an on-line detection system. The whole set-up was tested using short-lived osmium (Os) and mercury (Hg) nuclides produced in heavy ion reactions to model future chemical studies with hassium (Hs, Z=108) and element 112. By varying the temperature of the isothermal section of the chromatography column between room temperature and -80 deg. C, yield measurements of given species can be conducted, yielding information about the volatility o...

  17. On-line correction of beam portals in the treatment of prostate cancer using an endorectal balloon device

    Ciernik, Ilja F.; Baumert, Brigitta G.; Egli, Peter; Glanzmann, Christoph; Luetolf, Urs M.

    2002-01-01

    Background: Reproducible target volume assessment is required in order to optimize portal field margins in the treatment of prostate cancer. The benefits of an endorectal balloon on target volume assessment remain unclear. Material and methods: Nine patients were treated with a daily placed air filled rectal balloon. Portal films and computer-associated tomography during the treatment were used to determine the position of the structures of interest. Comparative planning with or without a balloon was performed in order to determine rectal wall exposure to radiation. Results: The range of movements during treatment predicting the position of the prostate in relation to the symphysis was 0.05-0.59 cm in the lateral direction, 0.27-2.2 cm in the antero-posterior direction, and 0.33-1.8 cm in the crano-caudal direction, as compared to the position of the prostate predicted by the balloon ranging from 0.18 to 0.76 cm in the lateral direction, 0.22-1.68 cm in the antero-posterior direction, and 0.58-2.99 cm in the crano-caudal direction. Planning target volumes (PTV) margins as defined by the position of the balloon were 10 mm in the antero-posterior direction, 6 mm in the lateral direction, and 16 mm in the crano-caudal direction. The volume of rectal wall exposed to radiation was reduced from 40 (±12%) to 25% (±19%) with an endorectal balloon (P<0.05). Conclusions: Daily online correction with portal vision for external beam set-up is improved by an endorectal balloon device, leading to improved PTV margins and reduced radiation exposure of the rectal wall

  18. Vertical Scan-Conversion for Filling Purposes

    Hersch, R. D.

    1988-01-01

    Conventional scan-conversion algorithms were developed independently of filling algorithms. They cause many problems, when used for filling purposes. However, today's raster printers and plotters require extended use of filling, especially for the generation of typographic characters and graphic line art. A new scan-conversion algorithm, called vertical scan-conversion has been specifically designed to meet the requirements of parity scan line fill algorithms. Vertical scan-conversion ensures...

  19. Cooperative scans

    M. Zukowski (Marcin); P.A. Boncz (Peter); M.L. Kersten (Martin)

    2004-01-01

    textabstractData mining, information retrieval and other application areas exhibit a query load with multiple concurrent queries touching a large fraction of a relation. This leads to individual query plans based on a table scan or large index scan. The implementation of this access path in most

  20. Automation in trace-element chemistry - Development of a fully automated on-line preconcentration device for trace analysis of heavy metals with atomic spectroscopy

    Michaelis, M.R.A.

    1990-01-01

    Scope of this work was the development of an automated system for trace element preconcentration to be used and integrated to analytic atomic spectroscopic methods like flame atomic absorption spectrometry (FAAS), graphite furnace atomic absorption spectrometry (GFAAS) or atomic emission spectroscopy with inductively coupled plasma (ICP-AES). Based on the newly developed cellulose-based chelating cation exchangers ethylene-diamin-triacetic acid cellulose (EDTrA-Cellulose) and sulfonated-oxine cellulose a flexible, computer-controlled instrument for automation of preconcentration and/or of matrix separation of heavy metals is described. The most important properties of these materials are fast exchange kinetics, good selectivity against alkaline and alkaline earth elements, good flow characteristics and good stability of the material and the chelating functions against changes in pH-values of reagents necessary in the process. The combination of the preconcentration device for on-line determinations of Zn, Cd, Pb, Ni, Fe, Co, Mn, V, Cu, La, U, Th is described for FAAS and for ICP-AES with a simultaneous spectrometer. Signal enhancement factors of 70 are achieved from preconcentration of 10 ml and on-line determination with FAAS due to signal quantification in peak-height mode. For GFAAS and for sequential ICP methods for off-line preconcentration are given. The optimization and adaption of the interface to the different characteristics of the analytical instrumentation is emphasized. For evaluation and future developments with respect to determination and/or preconcentration of anionic species like As, Se, Sb etc. instrument modifications are proposed and a development software is described. (Author)

  1. Cells for bioartificial liver devices: the human hepatoma-derived cell line C3A produces urea but does not detoxify ammonia.

    Mavri-Damelin, Demetra; Damelin, Leonard H; Eaton, Simon; Rees, Myrddin; Selden, Clare; Hodgson, Humphrey J F

    2008-02-15

    Extrahepatic bioartificial liver devices should provide an intact urea cycle to detoxify ammonia. The C3A cell line, a subclone of the hepatoma-derived HepG2 cell line, is currently used in this context as it produces urea, and this has been assumed to be reflective of ammonia detoxification via a functional urea cycle. However, based on our previous findings of perturbed urea-cycle function in the non-urea producing HepG2 cell line, we hypothesized that the urea produced by C3A cells was via a urea cycle-independent mechanism, namely, due to arginase II activity, and therefore would not detoxify ammonia. Urea was quantified using (15)N-ammonium chloride metabolic labelling with gas chromatography-mass spectrometry. Gene expression was determined by real-time reverse transcriptase-PCR, protein expression by western blotting, and functional activities with radiolabelling enzyme assays. Arginase inhibition studies used N(omega)-hydroxy-nor-L-arginine. Urea was detected in C3A conditioned medium; however, (15)N-ammonium chloride-labelling indicated that (15)N-ammonia was not incorporated into (15)N-labelled urea. Further, gene expression of two urea cycle genes, ornithine transcarbamylase and arginase I, were completely absent. In contrast, arginase II mRNA and protein was expressed at high levels in C3A cells and was inhibited by N(omega)-hydroxy-nor-L-arginine, which prevented urea production, thereby indicating a urea cycle-independent pathway. The urea cycle is non-functional in C3A cells, and their urea production is solely due to the presence of arginase II, which therefore cannot provide ammonia detoxification in a bioartificial liver system. This emphasizes the continued requirement for developing a component capable of a full repertoire of liver function. (c) 2007 Wiley Periodicals, Inc.

  2. Elevation scanning laser/multi-sensor hazard detection system controller and mirror/mast speed control components. [roving vehicle electromechanical devices

    Craig, J.; Yerazunis, S. W.

    1978-01-01

    The electro-mechanical and electronic systems involved with pointing a laser beam from a roving vehicle along a desired vector are described. A rotating 8 sided mirror, driven by a phase-locked dc motor servo system, and monitored by a precision optical shaft encoder is used. This upper assembly is then rotated about an orthogonal axis to allow scanning into all 360 deg around the vehicle. This axis is also driven by a phase locked dc motor servo-system, and monitored with an optical shaft encoder. The electronics are realized in standard TTL integrated circuits with UV-erasable proms used to store desired coordinates of laser fire. Related topics such as the interface to the existing test vehicle are discussed.

  3. Radionuclide scanning

    Shapiro, B.

    1986-01-01

    Radionuclide scanning is the production of images of normal and diseased tissues and organs by means of the gamma-ray emissions from radiopharmaceutical agents having specific distributions in the body. The gamma rays are detected at the body surface by a variety of instruments that convert the invisible rays into visible patterns representing the distribution of the radionuclide in the body. The patterns, or images, obtained can be interpreted to provide or to aid diagnoses, to follow the course of disease, and to monitor the management of various illnesses. Scanning is a sensitive technique, but its specificity may be low when interpreted alone. To be used most successfully, radionuclide scanning must be interpreted in conjunction with other techniques, such as bone radiographs with bone scans, chest radiographs with lung scans, and ultrasonic studies with thyroid scans. Interpretation is also enhanced by providing pertinent clinical information because the distribution of radiopharmaceutical agents can be altered by drugs and by various procedures besides physiologic and pathologic conditions. Discussion of the patient with the radionuclide scanning specialist prior to the study and review of the results with that specialist after the study are beneficial

  4. Genome-wide SNP scan of pooled DNA reveals nonsense mutation in FGF20 in the scaleless line of featherless chickens

    Wells Kirsty L

    2012-06-01

    Full Text Available Abstract Background Scaleless (sc/sc chickens carry a single recessive mutation that causes a lack of almost all body feathers, as well as foot scales and spurs, due to a failure of skin patterning during embryogenesis. This spontaneous mutant line, first described in the 1950s, has been used extensively to explore the tissue interactions involved in ectodermal appendage formation in embryonic skin. Moreover, the trait is potentially useful in tropical agriculture due to the ability of featherless chickens to tolerate heat, which is at present a major constraint to efficient poultry meat production in hot climates. In the interests of enhancing our understanding of feather placode development, and to provide the poultry industry with a strategy to breed heat-tolerant meat-type chickens (broilers, we mapped and identified the sc mutation. Results Through a cost-effective and labour-efficient SNP array mapping approach using DNA from sc/sc and sc/+ blood sample pools, we map the sc trait to chromosome 4 and show that a nonsense mutation in FGF20 is completely associated with the sc/sc phenotype. This mutation, common to all sc/sc individuals and absent from wild type, is predicted to lead to loss of a highly conserved region of the FGF20 protein important for FGF signalling. In situ hybridisation and quantitative RT-PCR studies reveal that FGF20 is epidermally expressed during the early stages of feather placode patterning. In addition, we describe a dCAPS genotyping assay based on the mutation, developed to facilitate discrimination between wild type and sc alleles. Conclusions This work represents the first loss of function genetic evidence supporting a role for FGF ligand signalling in feather development, and suggests FGF20 as a novel central player in the development of vertebrate skin appendages, including hair follicles and exocrine glands. In addition, this is to our knowledge the first report describing the use of the chicken SNP array to

  5. LIDAR COMBINED SCANNING UNIT

    V. V. Elizarov

    2016-11-01

    Full Text Available Subject of Research. The results of lidar combined scanning unit development for locating leaks of hydrocarbons are presented The unit enables to perform high-speed scanning of the investigated space in wide and narrow angle fields. Method. Scanning in a wide angular field is produced by one-line scanning path by means of the movable aluminum mirror with a frequency of 20Hz and amplitude of 20 degrees of swing. Narrowband scanning is performed along a spiral path by the deflector. The deflection of the beam is done by rotation of the optical wedges forming part of the deflector at an angle of ±50. The control function of the scanning node is performed by a specialized software product written in C# programming language. Main Results. This scanning unit allows scanning the investigated area at a distance of 50-100 m with spatial resolution at the level of 3 cm. The positioning accuracy of the laser beam in space is 15'. The developed scanning unit gives the possibility to browse the entire investigated area for the time not more than 1 ms at a rotation frequency of each wedge from 50 to 200 Hz. The problem of unambiguous definition of the beam geographical coordinates in space is solved at the software level according to the rotation angles of the mirrors and optical wedges. Lidar system coordinates are determined by means of GPS. Practical Relevance. Development results open the possibility for increasing the spatial resolution of scanning systems of a wide range of lidars and can provide high positioning accuracy of the laser beam in space.

  6. Scanning probe microscopy

    Mainsbridge, B.

    1994-01-01

    In late 1959, Richard Feynman observed that manoeuvring atoms was something that could be done in principle but has not been done, 'because we are too big'. In 1982, the scanning tunnelling microscope (STM) was invented and is now a central tool for the construction of nanoscale devices in what was known as molecular engineering, and now, nanotechnology. The principles of the microscope are outlined and references are made to other scanning devices which have evolved from the original invention. The method of employment of the STM as a machine tool is described and references are made to current speculations on applications of the instrument in nanotechnology. A short bibliography on this topic is included. 27 refs., 7 figs

  7. Scanning probe microscopy

    Mainsbridge, B [Murdoch Univ., WA (Australia). School of Mathematical and Physical Sciences

    1994-12-31

    In late 1959, Richard Feynman observed that manoeuvring atoms was something that could be done in principle but has not been done, `because we are too big`. In 1982, the scanning tunnelling microscope (STM) was invented and is now a central tool for the construction of nanoscale devices in what was known as molecular engineering, and now, nanotechnology. The principles of the microscope are outlined and references are made to other scanning devices which have evolved from the original invention. The method of employment of the STM as a machine tool is described and references are made to current speculations on applications of the instrument in nanotechnology. A short bibliography on this topic is included. 27 refs., 7 figs.

  8. The Leipzig Ice Nucleation chamber Comparison (LINC): An overview of ice nucleation measurements observed with four on-line ice nucleation devices

    Kohn, Monika; Wex, Heike; Grawe, Sarah; Hartmann, Susan; Hellner, Lisa; Herenz, Paul; Welti, André; Stratmann, Frank; Lohmann, Ulrike; Kanji, Zamin A.

    2016-04-01

    Mixed-phase clouds (MPCs) are found to be the most relevant cloud type leading to precipitation in mid-latitudes. The formation of ice crystals in MPCs is not completely understood. To estimate the effect of aerosol particles on the radiative properties of clouds and to describe ice nucleation in models, the specific properties of aerosol particles acting as ice nucleating particles (INPs) still need to be identified. A number of devices are able to measure INPs in the lab and in the field. However, methods can be very different and need to be tested under controlled conditions with respect to aerosol generation and properties in order to standardize measurement and data analysis approaches for subsequent ambient measurements. Here, we present an overview of the LINC campaign hosted at TROPOS in September 2015. We compare four ice nucleation devices: PINC (Portable Ice Nucleation Chamber, Chou et al., 2011) and SPIN (SPectrometer for Ice Nuclei) are operated in deposition nucleation and condensation freezing mode. LACIS (Leipzig Aerosol Cloud Interaction Simulator, Hartmann et al., 2011) and PIMCA (Portable Immersion Mode Cooling chamber) measure in the immersion freezing mode. PIMCA is used as a vertical extension to PINC and allows activation and droplet growth prior to exposure to the investigated ice nucleation temperature. Size-resolved measurements of multiple aerosol types were performed including pure mineral dust (K-feldspar, kaolinite) and biological particles (Birch pollen washing waters) as well as some of them after treatment with sulfuric or nitric acid prior to experiments. LACIS and PIMCA-PINC operated in the immersion freezing mode showed very good agreement in the measured frozen fraction (FF). For the comparison between PINC and SPIN, which were scanning relative humidity from below to above water vapor saturation, an agreement was found for the obtained INP concentration. However, some differences were observed, which may result from ice

  9. Doppler-shift spectra of Hα lines from negative-ion-based neutral beams for large helical device neutral beam injection

    Oka, Y.; Ikeda, K.; Takeiri, Y.; Tsumori, K.; Kaneko, O.; Nagaoka, K.; Osakabe, M.; Asano, E.; Kondo, T.; Sato, M.; Shibuya, M.; Grisham, L.; Umeda, N.; Honda, A.; Ikeda, Y.; Yamamoto, T.

    2006-01-01

    The velocity spectra of the negative-ion-(H - ) based neutral beams are studied in high-performance large-area ion sources during injection into large helical device fusion plasmas. We are conducting systematic observations in standard neutral beam injection to correlate beam spectra with source operating conditions. Almost all of the transmitted beam power was at full acceleration energy (∼170 keV). The small stripping beam component which was produced in the extraction gap was evaluated to be about 9%-22% by amplitude of the measured spectra for the sources in beam lines 1 and 2. H - production uniformity from the spectrum profile was 86%-90% for three sources. For the longest pulse injection during 74 and 128 s, a full energy component tended to decrease with time, while the accelerator gap stripping tail tended to increase slightly with time, which is attributed to beam-induced outgassing in the accelerator. A higher conductance multislot ground grid accelerator appeared to show little growth in the accelerator gap beam stripping during long pulses compared to the conventional multiaperture ground grid. The beam uniformity appeared to vary in part with the Cs uniformity on the plasma grid

  10. Scanning table

    1960-01-01

    Before the invention of wire chambers, particles tracks were analysed on scanning tables like this one. Today, the process is electronic and much faster. Bubble chamber film - currently available - (links can be found below) was used for this analysis of the particle tracks.

  11. Scan Statistics

    Glaz, Joseph

    2009-01-01

    Suitable for graduate students and researchers in applied probability and statistics, as well as for scientists in biology, computer science, pharmaceutical science and medicine, this title brings together a collection of chapters illustrating the depth and diversity of theory, methods and applications in the area of scan statistics.

  12. PLASMA DEVICE

    Gow, J.D.; Wilcox, J.M.

    1961-12-26

    A device is designed for producing and confining highenergy plasma from which neutrons are generated in copious quantities. A rotating sheath of electrons is established in a radial electric field and axial magnetic field produced within the device. The electron sheath serves as a strong ionizing medium to gas introdueed thereto and also functions as an extremely effective heating mechanism to the resulting plasma. In addition, improved confinement of the plasma is obtained by ring magnetic mirror fields produced at the ends of the device. Such ring mirror fields are defined by the magnetic field lines at the ends of the device diverging radially outward from the axis of the device and thereafter converging at spatial annular surfaces disposed concentrically thereabout. (AFC)

  13. Frequency scanning microstrip antennas

    Danielsen, Magnus; Jørgensen, Rolf

    1979-01-01

    The principles of using radiating microstrip resonators as elements in a frequency scanning antenna array are described. The resonators are cascade-coupled. This gives a scan of the main lobe due to the phase-shift in the resonator in addition to that created by the transmission line phase......-shift. Experimental results inX-band, in good agreement with the theory, show that it is possible to scan the main lobe an angle ofpm30degby a variation of the frequencypm300MHz, and where the 3 dB beamwidth is less than10deg. The directivity was 14.7 dB, while the gain was 8.1 dB. The efficiency might be improved...

  14. Use of a line-pair resolution phantom for comprehensive quality assurance of electronic portal imaging devices based on fundamental imaging metrics

    Gopal, Arun; Samant, Sanjiv S.

    2009-01-01

    Image guided radiation therapy solutions based on megavoltage computed tomography (MVCT) involve the extension of electronic portal imaging devices (EPIDs) from their traditional role of weekly localization imaging and planar dose mapping to volumetric imaging for 3D setup and dose verification. To sustain the potential advantages of MVCT, EPIDs are required to provide improved levels of portal image quality. Therefore, it is vital that the performance of EPIDs in clinical use is maintained at an optimal level through regular and rigorous quality assurance (QA). Traditionally, portal imaging QA has been carried out by imaging calibrated line-pair and contrast resolution phantoms and obtaining arbitrarily defined QA indices that are usually dependent on imaging conditions and merely indicate relative trends in imaging performance. They are not adequately sensitive to all aspects of image quality unlike fundamental imaging metrics such as the modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE) that are widely used to characterize detector performance in radiographic imaging and would be ideal for QA purposes. However, due to the difficulty of performing conventional MTF measurements, they have not been used for routine clinical QA. The authors present a simple and quick QA methodology based on obtaining the MTF, NPS, and DQE of a megavoltage imager by imaging standard open fields and a bar-pattern QA phantom containing 2 mm thick tungsten line-pair bar resolution targets. Our bar-pattern based MTF measurement features a novel zero-frequency normalization scheme that eliminates normalization errors typically associated with traditional bar-pattern measurements at megavoltage x-ray energies. The bar-pattern QA phantom and open-field images are used in conjunction with an automated image analysis algorithm that quickly computes the MTF, NPS, and DQE of an EPID system. Our approach combines the fundamental advantages of

  15. Bone scans

    Hetherington, V.J.

    1989-01-01

    Oftentimes, in managing podiatric complaints, clinical and conventional radiographic techniques are insufficient in determining a patient's problem. This is especially true in the early stages of bone infection. Bone scanning or imaging can provide additional information in the diagnosis of the disorder. However, bone scans are not specific and must be correlated with clinical, radiographic, and laboratory evaluation. In other words, bone scanning does not provide the diagnosis but is an important bit of information aiding in the process of diagnosis. The more useful radionuclides in skeletal imaging are technetium phosphate complexes and gallium citrate. These compounds are administered intravenously and are detected at specific time intervals postinjection by a rectilinear scanner with minification is used and the entire skeleton can be imaged from head to toe. Minification allows visualization of the entire skeleton in a single image. A gamma camera can concentrate on an isolated area. However, it requires multiple views to complete the whole skeletal image. Recent advances have allowed computer augmentation of the data received from radionucleotide imaging. The purpose of this chapter is to present the current radionuclides clinically useful in podiatric patients

  16. Elemental Scanning Devices Authenticate Works of Art

    2013-01-01

    To better detect aluminum compounds, Marshall Space Flight Center partnered with KeyMaster Inc. (later acquired by Madison, Wisconsin-based Bruker AXS Inc.) to develop a vacuum pump system that could be attached to X-ray fluorescence (XRF) scanners. The resulting technology greatly expanded XRF scanner capabilities, and hundreds of museums now use them to authenticate artifacts and works of art.

  17. Realization of a scanning ion beam monitor

    Pautard, C.

    2008-07-01

    During this thesis, a scanning ion beam monitor has been developed in order to measure on-line fluence spatial distributions. This monitor is composed of an ionization chamber, Hall Effect sensors and a scintillator. The ionization chamber set between the beam exit and the experiment measures the ion rate. The beam spot is localized thanks to the Hall Effect sensors set near the beam sweeping magnets. The scintillator is used with a photomultiplier tube to calibrate the ionization chamber and with an imaging device to calibrate the Hall Effect sensors. This monitor was developed to control the beam lines of a radiobiology dedicated experimentation room at GANIL. These experiments are held in the context of the research in hadron-therapy. As a matter of fact, this new cancer treatment technique is based on ion irradiations and therefore demands accurate knowledge about the relation between the dose deposit in biological samples and the induced effects. To be effective, these studies require an on-line control of the fluence. The monitor has been tested with different beams at GANIL. Fluence can be measured with a relative precision of ±4% for a dose rate ranging between 1 mGy/s and 2 Gy/s. Once permanently set on the beam lines dedicated to radiobiology at GANIL, this monitor will enable users to control the fluence spatial distribution for each irradiation. The scintillator and the imaging device are also used to control the position, the spot shape and the energy of different beams such as those used for hadron-therapy. (author)

  18. Scanning by use of TV

    Drevermann, H.

    1981-01-01

    The use of TV read out for scanning and measuring holographic pictures seems to give less problems than the use of optical projection as is usual for conventional bubble chamber photos. Whereas the measuring of conventional bubble chamber pictures seems to give no problems, it is not clear whether scanning by use of TV is possible. Therefore scanning pictures from experiment NA16 (taken in LEBC) with TV only was tried using the TV system of ERASME, where the CRT system is used as a camera. It should be mentioned that this system, being a flying spot device, cannot be adapted for holography. (author)

  19. Optical Structural Health Monitoring Device

    Buckner, Benjamin D.; Markov, Vladimir; Earthman, James C.

    2010-01-01

    This non-destructive, optical fatigue detection and monitoring system relies on a small and unobtrusive light-scattering sensor that is installed on a component at the beginning of its life in order to periodically scan the component in situ. The method involves using a laser beam to scan the surface of the monitored component. The device scans a laser spot over a metal surface to which it is attached. As the laser beam scans the surface, disruptions in the surface cause increases in scattered light intensity. As the disruptions in the surface grow, they will cause the light to scatter more. Over time, the scattering intensities over the scanned line can be compared to detect changes in the metal surface to find cracks, crack precursors, or corrosion. This periodic monitoring of the surface can be used to indicate the degree of fatigue damage on a component and allow one to predict the remaining life and/or incipient mechanical failure of the monitored component. This wireless, compact device can operate for long periods under its own battery power and could one day use harvested power. The prototype device uses the popular open-source TinyOS operating system on an off-the-shelf Mica2 sensor mote, which allows wireless command and control through dynamically reconfigurable multi-node sensor networks. The small size and long life of this device could make it possible for the nodes to be installed and left in place over the course of years, and with wireless communication, data can be extracted from the nodes by operators without physical access to the devices. While a prototype has been demonstrated at the time of this reporting, further work is required in the system s development to take this technology into the field, especially to improve its power management and ruggedness. It should be possible to reduce the size and sensitivity as well. Establishment of better prognostic methods based on these data is also needed. The increase of surface roughness with

  20. Strainer device

    Mokuya, Kenji.

    1975-01-01

    Object: To provide a strainer device, which is adapted to facilitate flushing and is particularly suited for installation in the cooling system of a liquid metal cooled fast breeding reactor. Structure: A casing accommodating a strainer and a blind plate for the selection of a flow path is provided at a suitable portion of the duct line. The blind plate is adapted to be rotated by an opening and closing means consisting of a rod. bellows, shaft and so forth. At the time of flushing, the duct line is sealed by the blind plate. (Nakamura, S.)

  1. Irradiation device

    Suzuki, Toshimitsu.

    1989-01-01

    In an irradiation device for irradiating radiation rays such as electron beams to pharmaceuticals, etc., since the distribution of scanned electron rays was not monitored, the electron beam intensity could be determined only indirectly and irradiation reliability was not satisfactory. In view of the above, a plurality of monitor wires emitting secondary electrons are disposed in the scanning direction near a beam take-out window of a scanning duct, signals from the monitor wires are inputted into a display device such as a cathode ray tube, as well as signals from the monitor wires at the central portion are inputted into counting rate meters to measure the radiation dose as well. Since secondary electrons are emitted when electron beams pass through the monitor wires and the intensity thereof is in proportion with the intensity of incident electron beams, the distribution of the radiation dose can be monitored by measuring the intensity of the emitted secondary electrons. Further, uneven irradiation, etc. can also be monitored to make the radiation of irradiation rays reliable. (N.H.)

  2. Construction of a scanning system at SAGA-HIMAT

    Kanazawa, Mitsutaka; Endo, Masahiro; Mizota, Manabu

    2016-01-01

    In SAGA-HIMAT, 620 cancer treatments were done by use of two irradiation rooms in 2015 financial year. To increase treatment capacity of our facility, we have started the construction of the third treatment room C with a scanning irradiation system at the beginning of 2014. This construction was required to do without interruption on the treatment in room A and room B. With this requirement, installations of the beam line and irradiation devices were carried out in the night time and weak end, and beam tests were also. Though there are many things to improve, test irradiation is becoming possible. In this talk, we will present our development status. (author)

  3. Spectroscopic ellipsometric modeling of a Bi–Te–Se write layer of an optical data storage device as guided by atomic force microscopy, scanning electron microscopy, and X-ray diffraction

    Wang, Hao; Madaan, Nitesh; Bagley, Jacob; Diwan, Anubhav [Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602 (United States); Liu, Yiqun [Department of Chemistry, Lehigh University, Bethlehem, PA 18015 (United States); Davis, Robert C. [Department of Physics and Astronomy, Brigham Young University, Provo, UT 84602 (United States); Lunt, Barry M. [Department of Information Technology, Brigham Young University, Provo, UT 84602 (United States); Smith, Stacey J., E-mail: ssmith@chem.byu.edu [Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602 (United States); Linford, Matthew R., E-mail: mrlinford@chem.byu.edu [Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602 (United States)

    2014-10-31

    Conventional magnetic tape is the most widely used medium for archival data storage. However, data stored on it need to be migrated every ca. 5 years. Recently, optical discs that store information for hundreds, or even more than 1000 years, have been introduced to the market. We recently proposed that technology in these optical discs be used to make an optical tape that would show greater permanence than its magnetic counterpart. Here we provide a detailed optical characterization of a sputtered thin film of bismuth, tellurium, and selenium (BTS) that is a proposed data storage layer for these devices. The methodology described herein should be useful in the future development of related materials. Spectroscopic ellipsometry (SE) data are obtained using interference enhancement, and the modeling of this data is guided by results from atomic force microscopy (AFM), scanning electron microscopy (SEM), X-ray diffraction (XRD), and X-ray reflectivity (XRR). By AFM, ca. 40 nm BTS films show ca. 10 nm roughness. SEM images also suggest considerable roughness in the films and indicate that they are composed of 13.1 ± 5.9 nm grains. XRD confirms that the films are crystalline and predicts a grain size of 17 ± 2 nm. XRD results are consistent with the composition of the films — a mildly oxidized BTS material. Three models of increasing complexity are investigated to explain the SE data. The first model consists of a smooth, homogeneous BTS film. The second model adds a roughness layer to the previous model. The third model also has two layers. The bottom layer is modeled as a mixture of BTS and void using a Bruggeman effective medium approximation. The upper layer is similarly modeled, but with a gradient. The first model was unable to adequately model the SE data. The second model was an improvement — lower MSE (4.4) and good agreement with step height measurements. The third model was even better — very low MSE (2.6) and good agreement with AFM results. The

  4. Bone Densitometry (Bone Density Scan)

    ... made of metal. Objects such as keys or wallets that would be in the area being scanned should be removed. You will ... and are often available in drugstores and on mobile health vans in the community. The pDEXA device is much smaller than ...

  5. Scanning unit for collectrons

    Plaige, Yves.

    1976-01-01

    This invention concerns a measurement scanning assembly for collectron type detectors. It is used in measuring the neutron flux in nuclear reactors. As the number of these detectors in a reactor can be very great, they are not usually all connected permanently to the measuring facility but rather in turn by means of a scanning device which carries out, as it were, multiplexing between all the collectrons and the input of a single measuring system. The object of the invention is a scanning assembly which is of relative simplicity through an original organisation. Specifically, according to this organisation, the collectrons outputs are grouped together in bunches, each of these bunches being processed by a multiplexing sub-assembly belonging to a first stage, the different outputs of these multiplexing subassemblies of this first stage being grouped together yet again in bunches processed by multiplexors forming a new stage and so forth. Further, this structure is specially adapted for use with collectrons by utilising a current amplifier at each multiplexing level so that from one end to the other of the multiplexing system, the commutations are carried out on currents and not on voltages [fr

  6. Head CT scan

    ... scan - orbits; CT scan - sinuses; Computed tomography - cranial; CAT scan - brain ... head size in children Changes in thinking or behavior Fainting Headache, when you have certain other signs ...

  7. ELGA and TOR installations control device to carry out experiments on-line with a mass-separator by the ASNAPP-2 code

    Arvai, Z.; Guyash, Ya.; Kuznetsov, V.V.; Fominykh, V.I.

    1984-01-01

    The control device of the tor beta-spectrometer with toroidal magnetic field and the ELGA spectrometer with semiconductor detectors for investigation of conversion electrons, positrons, γ- and α-radiations and lifetime of excited states and periods of isotopes half-decay are described. The block-diagram of the measurement processes, algorithm of the ELGA devce operation, control device circuit, and circuit for connection of analog-to-digital converter with the CAMAC dataway, block-diagram of step motor control, and step motor feeding scheme as well as mechanical and electrical characteristics of the step motor are given. The device is used for spectroscopic investigations of short-lived isotopes on the accelerator proton beam with mass separator

  8. ELT-MELAS analyzer and its on-line programs

    Anikeev, V.B.; Berezhnoj, V.A.; Glupova

    1976-01-01

    ELT-MELAS device constructed for an automatic analysis of pictures from big bubble chambers is described. It is controlled by a medium-size ICL-1903A computer and has two measuring modes: analysis of the ''agreement'' signal and digitation of slice-scans. Main features of the hardware and of on-line controlling and diagnostic software are presented. The test results of the MELAS complex as well as preliminary results of the scan-slice measurements of pictures from 15sup(') chamber are given

  9. Forensic Scanning Electron Microscope

    Keeley, R. H.

    1983-03-01

    The scanning electron microscope equipped with an x-ray spectrometer is a versatile instrument which has many uses in the investigation of crime and preparation of scientific evidence for the courts. Major applications include microscopy and analysis of very small fragments of paint, glass and other materials which may link an individual with a scene of crime, identification of firearms residues and examination of questioned documents. Although simultaneous observation and chemical analysis of the sample is the most important feature of the instrument, other modes of operation such as cathodoluminescence spectrometry, backscattered electron imaging and direct x-ray excitation are also exploited. Marks on two bullets or cartridge cases can be compared directly by sequential scanning with a single beam or electronic linkage of two instruments. Particles of primer residue deposited on the skin and clothing when a gun is fired can be collected on adhesive tape and identified by their morphology and elemental composition. It is also possible to differentiate between the primer residues of different types of ammunition. Bullets may be identified from the small fragments left behind as they pass through the body tissues. In the examination of questioned documents the scanning electron microscope is used to establish the order in which two intersecting ink lines were written and to detect traces of chemical markers added to the security inks on official documents.

  10. Handbook of optical and laser scanning

    Marshall, Gerald F

    2011-01-01

    From its initial publication titled Laser Beam Scanning in 1985 to Handbook of Optical and Laser Scanning, now in its second edition, this reference has kept professionals and students at the forefront of optical scanning technology. Carefully and meticulously updated in each iteration, the book continues to be the most comprehensive scanning resource on the market. It examines the breadth and depth of subtopics in the field from a variety of perspectives. The Second Edition covers: Technologies such as piezoelectric devices Applications of laser scanning such as Ladar (laser radar) Underwater

  11. Scanning Capacitance Microscopy | Materials Science | NREL

    obtained using scanning capacitance microscopy. Top Right: Image of p-type and n-type material, obtained 'fingers' of light-colored n-type material on a yellow and blue background representing p-type material material, obtained using scanning capacitance microscopy, in a sample semiconductor device; the image shows

  12. Growth arrest line mimicking lymphoma involvement: The findings of {sup 99m}Tc-MDP bone SPECT/CT and serial bone scan in a child with non-Hodgkin's lymphoma

    Kim, Chan Woo; Kim, Ji Young; Choi, Yun Young; Lee, Seung Hun; Lee, Young Ho [Hanyang University Medical Center, Seoul (Korea, Republic of)

    2016-06-15

    Growth arrest lines appear as dense sclerotic lines parallel to the growth plate of long bones on radiography. We describe the case of a 9-year-old female with growth arrest lines initially masquerading as lymphoma involvement on {sup 99m}Tc-MDP bone scintigraphy who had been treated with chemotherapy for non-Hodgkin's lymphoma about 3 years previously. Subsequent regional bone SPECT/CT clearly diagnosed the growth arrest lines, and retrograde review of previous bone scintigraphy demonstrated line migration in this patient. Growth arrest lines should be considered a possible diagnosis on bone scintigraphy, especially in the surveillance of children who have experienced severe childhood infections, malnutrition, immobilization, or treatment with immunosuppressive or chemotherapeutic drugs that may inhibit bone growth.

  13. Growth arrest line mimicking lymphoma involvement: The findings of 99mTc-MDP bone SPECT/CT and serial bone scan in a child with non-Hodgkin's lymphoma

    Kim, Chan Woo; Kim, Ji Young; Choi, Yun Young; Lee, Seung Hun; Lee, Young Ho

    2016-01-01

    Growth arrest lines appear as dense sclerotic lines parallel to the growth plate of long bones on radiography. We describe the case of a 9-year-old female with growth arrest lines initially masquerading as lymphoma involvement on 99m Tc-MDP bone scintigraphy who had been treated with chemotherapy for non-Hodgkin's lymphoma about 3 years previously. Subsequent regional bone SPECT/CT clearly diagnosed the growth arrest lines, and retrograde review of previous bone scintigraphy demonstrated line migration in this patient. Growth arrest lines should be considered a possible diagnosis on bone scintigraphy, especially in the surveillance of children who have experienced severe childhood infections, malnutrition, immobilization, or treatment with immunosuppressive or chemotherapeutic drugs that may inhibit bone growth

  14. CAMAC gamma ray scanning system

    Moss, C.E.; Pratt, J.C.; Shunk, E.R.

    1981-01-01

    A flexible gamma-ray scanning system, based on a LeCroy 3500 multichannel analyzer and CAMAC modules, is described. The system is designed for making simultaneous passive and active scans of objects of interest to nuclear safeguards. The scanner is a stepping-motor-driven carriage; the detectors, a bismuth-germanate scintillator and a high-purity germanium detector. A total of sixteen peaks in the two detector-produced spectra can be integrated simultaneously, and any scan can be viewed during data acquisition. For active scanning, the 2615-keV gamma-ray line from a 232 U source and the 4439-keV gamma-ray line from 9 Be(α,n) 12 C were selected. The system can be easily reconfigured to accommodate up to seven detectors because it is based on CAMAC modules and FORTRAN. The system is designed for field use and is easily transported. Examples of passive and active scans are presented

  15. A Scanning Microwave Radar and Radiometer

    Skou, Niels

    1995-01-01

    The Scanning Microwave Radar and Radiometer (SMRR) is a line scanner featuring a combined radar and radiometer system operating around 35 and 94 GHz. The layout of the SMRR is shown. The 2 offset antenna parabolas scan in synchronism, the receiver antenna has the highest gain in order to ensure...

  16. Brain PET scan

    ... results on a PET scan. Blood sugar or insulin levels may affect the test results in people with diabetes . PET scans may be done along with a CT scan. This combination scan is called a PET/CT. Alternative Names Brain positron emission tomography; PET scan - brain References Chernecky ...

  17. Postprocessing Algorithm for Driving Conventional Scanning Tunneling Microscope at Fast Scan Rates.

    Zhang, Hao; Li, Xianqi; Chen, Yunmei; Park, Jewook; Li, An-Ping; Zhang, X-G

    2017-01-01

    We present an image postprocessing framework for Scanning Tunneling Microscope (STM) to reduce the strong spurious oscillations and scan line noise at fast scan rates and preserve the features, allowing an order of magnitude increase in the scan rate without upgrading the hardware. The proposed method consists of two steps for large scale images and four steps for atomic scale images. For large scale images, we first apply for each line an image registration method to align the forward and backward scans of the same line. In the second step we apply a "rubber band" model which is solved by a novel Constrained Adaptive and Iterative Filtering Algorithm (CIAFA). The numerical results on measurement from copper(111) surface indicate the processed images are comparable in accuracy to data obtained with a slow scan rate, but are free of the scan drift error commonly seen in slow scan data. For atomic scale images, an additional first step to remove line-by-line strong background fluctuations and a fourth step of replacing the postprocessed image by its ranking map as the final atomic resolution image are required. The resulting image restores the lattice image that is nearly undetectable in the original fast scan data.

  18. Postprocessing Algorithm for Driving Conventional Scanning Tunneling Microscope at Fast Scan Rates

    Hao Zhang

    2017-01-01

    Full Text Available We present an image postprocessing framework for Scanning Tunneling Microscope (STM to reduce the strong spurious oscillations and scan line noise at fast scan rates and preserve the features, allowing an order of magnitude increase in the scan rate without upgrading the hardware. The proposed method consists of two steps for large scale images and four steps for atomic scale images. For large scale images, we first apply for each line an image registration method to align the forward and backward scans of the same line. In the second step we apply a “rubber band” model which is solved by a novel Constrained Adaptive and Iterative Filtering Algorithm (CIAFA. The numerical results on measurement from copper(111 surface indicate the processed images are comparable in accuracy to data obtained with a slow scan rate, but are free of the scan drift error commonly seen in slow scan data. For atomic scale images, an additional first step to remove line-by-line strong background fluctuations and a fourth step of replacing the postprocessed image by its ranking map as the final atomic resolution image are required. The resulting image restores the lattice image that is nearly undetectable in the original fast scan data.

  19. Automation of BESSY scanning tables

    Hanton, J.; Kesteman, J.

    1981-01-01

    A micro processor M6800 is used for the automation of scanning and premeasuring BESSY tables. The tasks achieved by the micro processor are: 1. control of spooling of the four asynchronous film winding devices and switching on and off the 4 projections lamps, 2. pre-processing of the data coming from a bi-polar coordinates measuring device, 3. bi-directional interchange of informations between the operator, the BESSY table and the DEC PDP 11/34 mini computer controling the scanning operations, 4. control of the magnification on the table by swapping the projection lenses of appropriate focal lengths and the associated light boxes (under development). In connection with point 4, study is being made for the use of BESSY tables for accurate measurements (+/-5 microns), by encoding the displacements of the projections lenses. (orig.)

  20. Testing the variability of PSA expression by different human prostate cancer cell lines by means of a new potentiometric device employing molecularly antibody assembled on graphene surface

    Rebelo, Tânia S.C.R.; Noronha, João P.; Galésio, Marco; Santos, Hugo; Diniz, Mário; Sales, M. Goreti F.; Fernandes, Maria H.; Costa-Rodrigues, João

    2016-01-01

    Prostate Specific Antigen (PSA) is widely used as a biomarker for prostate cancer. Recently, an electrochemical biosensor for PSA detection by means of molecularly imprinted polymers (MIPs) was developed. This work evaluated the performance and the effectiveness of that PSA biosensor in screening the biomarker PSA in biological media with complex composition, collected from different human prostate cell line cultures. For that, the prostate cancer LNCaP and PC3 cells, and the non-cancerous prostate cell line PNT2 were cultured for 2, 7 and 14 days in either α-MEM or RPMI in the presence of 10% or 30% fetal bovine serum. Human gingival fibroblasts were used as a non-cancerous non-prostatic control. The different culture conditions modulated cellular proliferation and the expression of several prostate markers, including PSA. The electrochemical biosensor was able to specifically detect PSA in the culture media and values obtained were similar to those achieved by a commercial Enzyme-Linked Immunosorbent Assay (ELISA) kit, the most commonly used method for PSA quantification in prostate cancer diagnosis. Thus, the tested biosensor may represent a useful alternative as a diagnostic tool for PSA determination in biological samples. - Highlights: • PSA quantification was performed in prostate cancer cell culture media. • Culture media composition and culture period significantly affect PSA production. • The PSA biosensor detected a wide range of PSA levels in complex media. • A high data correlation was observed between the biosensor and the ELISA analysis.

  1. Testing the variability of PSA expression by different human prostate cancer cell lines by means of a new potentiometric device employing molecularly antibody assembled on graphene surface

    Rebelo, Tânia S.C.R. [BioMark-CINTESIS/ISEP, Instituto Superior de Engenharia do Instituto Politécnico do Porto (Portugal); LAQV, REQUIMTE, Departamento de Química, Faculdade de Ciências e Tecnologia, Universidade Nova de Lisboa, Caparica (Portugal); Laboratory for Bone Metabolism and Regeneration, Faculdade de Medicina Dentária, Universidade do Porto, Porto (Portugal); Noronha, João P.; Galésio, Marco; Santos, Hugo; Diniz, Mário [LAQV, REQUIMTE, Departamento de Química, Faculdade de Ciências e Tecnologia, Universidade Nova de Lisboa, Caparica (Portugal); Sales, M. Goreti F. [BioMark-CINTESIS/ISEP, Instituto Superior de Engenharia do Instituto Politécnico do Porto (Portugal); Fernandes, Maria H. [Laboratory for Bone Metabolism and Regeneration, Faculdade de Medicina Dentária, Universidade do Porto, Porto (Portugal); Costa-Rodrigues, João, E-mail: jrodrigues@fmd.up.pt [Laboratory for Bone Metabolism and Regeneration, Faculdade de Medicina Dentária, Universidade do Porto, Porto (Portugal); ESTSP — Escola Superior de Tecnologia da Saúde do Porto, Instituto Politécnico do Porto (Portugal)

    2016-02-01

    Prostate Specific Antigen (PSA) is widely used as a biomarker for prostate cancer. Recently, an electrochemical biosensor for PSA detection by means of molecularly imprinted polymers (MIPs) was developed. This work evaluated the performance and the effectiveness of that PSA biosensor in screening the biomarker PSA in biological media with complex composition, collected from different human prostate cell line cultures. For that, the prostate cancer LNCaP and PC3 cells, and the non-cancerous prostate cell line PNT2 were cultured for 2, 7 and 14 days in either α-MEM or RPMI in the presence of 10% or 30% fetal bovine serum. Human gingival fibroblasts were used as a non-cancerous non-prostatic control. The different culture conditions modulated cellular proliferation and the expression of several prostate markers, including PSA. The electrochemical biosensor was able to specifically detect PSA in the culture media and values obtained were similar to those achieved by a commercial Enzyme-Linked Immunosorbent Assay (ELISA) kit, the most commonly used method for PSA quantification in prostate cancer diagnosis. Thus, the tested biosensor may represent a useful alternative as a diagnostic tool for PSA determination in biological samples. - Highlights: • PSA quantification was performed in prostate cancer cell culture media. • Culture media composition and culture period significantly affect PSA production. • The PSA biosensor detected a wide range of PSA levels in complex media. • A high data correlation was observed between the biosensor and the ELISA analysis.

  2. Heart PET scan

    ... nuclear medicine scan; Heart positron emission tomography; Myocardial PET scan ... A PET scan requires a small amount of radioactive material (tracer). This tracer is given through a vein (IV), ...

  3. Sb(III) and Sb(V) separation and analytical speciation by a continuous tandem on-line separation device in connection with inductively coupled plasma atomic emission spectrometry

    Menendez Garcia, A. [Oviedo Univ. (Spain). Dept. of Phys. and Anal. Chem.; Perez Rodriguez, M.C. [Oviedo Univ. (Spain). Dept. of Phys. and Anal. Chem.; Sanchez Uria, J.F. [Oviedo Univ. (Spain). Dept. of Phys. and Anal. Chem.; Sanz-Medel, A. [Oviedo Univ. (Spain). Dept. of Phys. and Anal. Chem.

    1995-09-01

    A sensitive, precise and automated non-chromatographic method for Sb(III) and Sb(V) analytical speciation based on a continuous tandem on-line separation device in connection with inductively coupled plasma-atomic emission (ICP-AES) detection is proposed. Two on-line successive separation steps are included into this method: a continuous liquid-liquid extraction of Sb(III) with ammonium pyrrolidine dithiocarbamate (APDC) into methylisobuthylketone (MIBK), followed by direct stibine generation from the organic phase. Both separation steps are carried out in a continuous mode and on-line with the ICP-AES detector. Optimization of experimental conditions for the tandem separation and ICP-AES detection are investigated in detail. Detection limits for Sb(III) were 3 ng.mL{sup -1} and for Sb(V) 8 ng.mL{sup -1}. Precisions observed are in the range {+-} 5%. The proposed methodology has been applied to Sb(III) and Sb(V) speciation in sea-water samples. (orig.)

  4. Mouse manipulation through single-switch scanning.

    Blackstien-Adler, Susie; Shein, Fraser; Quintal, Janet; Birch, Shae; Weiss, Patrice L Tamar

    2004-01-01

    Given the current extensive reliance on the graphical user interface, independent access to computer software requires that users be able to manipulate a pointing device of some type (e.g., mouse, trackball) or be able to emulate a mouse by some other means (e.g., scanning). The purpose of the present study was to identify one or more optimal single-switch scanning mouse emulation strategies. Four alternative scanning strategies (continuous Cartesian, discrete Cartesian, rotational, and hybrid quadrant/continuous Cartesian) were selected for testing based on current market availability as well as on theoretical considerations of their potential speed and accuracy. Each strategy was evaluated using a repeated measures study design by means of a test program that permitted mouse emulation via any one of four scanning strategies in a motivating environment; response speed and accuracy could be automatically recorded and considered in view of the motor, cognitive, and perceptual demands of each scanning strategy. Ten individuals whose disabilities required them to operate a computer via single-switch scanning participated in the study. Results indicated that Cartesian scanning was the preferred and most effective scanning strategy. There were no significant differences between results from the Continuous Cartesian and Discrete Cartesian scanning strategies. Rotational scanning was quite slow with respect to the other strategies, although it was equally accurate. Hybrid Quadrant scanning improved access time but at the cost of fewer correct selections. These results demonstrated the importance of testing and comparing alternate single-switch scanning strategies.

  5. Investigation of the use of microwave image line integrated circuits for use in radiometers and other microwave devices in X-band and above

    Knox, R. M.; Toulios, P. P.; Onoda, G. Y.

    1972-01-01

    Program results are described in which the use of a/high permittivity rectangular dielectric image waveguide has been investigated for use in microwave and millimeter wavelength circuits. Launchers from rectangular metal waveguide to image waveguide are described. Theoretical and experimental evaluations of the radiation from curved image waveguides are given. Measurements of attenuation due to conductor and dielectric losses, adhesives, and gaps between the dielectric waveguide and the image plane are included. Various passive components are described and evaluations given. Investigations of various techniques for fabrication of image waveguide circuits using ceramic waveguides are also presented. Program results support the evaluation of the image line approach as an advantageous method for realizing low loss integrated electronic circuits for X-band and above.

  6. Scanning probe lithography for nanoimprinting mould fabrication

    Luo Gang; Xie Guoyong; Zhang Yongyi; Zhang Guoming; Zhang Yingying; Carlberg, Patrick; Zhu Tao; Liu Zhongfan

    2006-01-01

    We propose a rational fabrication method for nanoimprinting moulds by scanning probe lithography. By wet chemical etching, different kinds of moulds are realized on Si(110) and Si(100) surfaces according to the Si crystalline orientation. The structures have line widths of about 200 nm with a high aspect ratio. By reactive ion etching, moulds with patterns free from the limitation of Si crystalline orientation are also obtained. With closed-loop scan control of a scanning probe microscope, the length of patterned lines is more than 100 μm by integrating several steps of patterning. The fabrication process is optimized in order to produce a mould pattern with a line width about 10 nm. The structures on the mould are further duplicated into PMMA resists through the nanoimprinting process. The method of combining scanning probe lithography with wet chemical etching or reactive ion etching (RIE) provides a resistless route for the fabrication of nanoimprinting moulds

  7. PINPIN a-Si:H based structures for X-ray image detection using the laser scanning technique

    Fernandes, M.; Vygranenko, Y.; Vieira, M.

    2015-05-01

    Conventional film based X-ray imaging systems are being replaced by their digital equivalents. Different approaches are being followed by considering direct or indirect conversion, with the later technique dominating. The typical, indirect conversion, X-ray panel detector uses a phosphor for X-ray conversion coupled to a large area array of amorphous silicon based optical sensors and a couple of switching thin film transistors (TFT). The pixel information can then be readout by switching the correspondent line and column transistors, routing the signal to an external amplifier. In this work we follow an alternative approach, where the electrical switching performed by the TFT is replaced by optical scanning using a low power laser beam and a sensing/switching PINPIN structure, thus resulting in a simpler device. The optically active device is a PINPIN array, sharing both front and back electrical contacts, deposited over a glass substrate. During X-ray exposure, each sensing side photodiode collects photons generated by the scintillator screen (560 nm), charging its internal capacitance. Subsequently a laser beam (445 nm) scans the switching diodes (back side) retrieving the stored charge in a sequential way, reconstructing the image. In this paper we present recent work on the optoelectronic characterization of the PINPIN structure to be incorporated in the X-ray image sensor. The results from the optoelectronic characterization of the device and the dependence on scanning beam parameters are presented and discussed. Preliminary results of line scans are also presented.

  8. Measuring the plutonium distribution in fuel elements by the gamma scanning method

    Gorobets, A.K.; Leshchenko, Yu.I.; Semenov, A.L.

    1982-01-01

    An on-line system designed for measuring Pu distribution in the length of fresh fuel elements with vibrocompacted UO 2 -PuO 2 fuel rods by the γ-scanning method is described. An algorithm for measurement result processing and the procedure of determination of calibration parameters necessary for the valid signal separat.ion by means of a two-channel analyzer and for evaluation of the self-absorption effect are considered. The device scanning unit consists of two NaI(Tl) detectors simultaneously detecting γ-radiation from the opposite sides of a measured fuel rod section. The cesium source with Esub(γ)=660 keV is used for fuel scanning. On the base of the analysis of the results obtained when studying the BOR-60 experimental fuel elements with fuel rods of 400 mm long by means of the described device clusion is made that fuel element scanning during 20 min (scanning step is 4 mm, measuring time at each step is 10 s) makes it possible to determine Pu distribution with the error less than +-4% at the confidence probability of 0.68

  9. Small-size low-temperature scanning tunnel microscope

    Al'tfeder, I.B.; Khajkin, M.S.

    1989-01-01

    A small-size scanning tunnel microscope, designed for operation in transport helium-filled Dewar flasks is described. The microscope design contains a device moving the pin to the tested sample surface and a piezoelectric fine positioning device. High vibration protection of the microscope is provided by its suspension using silk threads. The small-size scanning tunnel microscope provides for atomic resolution

  10. First PET scans in Estonia

    Nazarenko, Sergei

    2003-01-01

    First PET scans in Estonia were performed on 25th November 2002 in North Estonia Regional Hospital, Tallinn. Six patients with melanoma underwent scanning with FDG. This event was a result of thorough extensive preparations first started in 2000 during the European Association of Nuclear Medicine congress in Paris. During the congress first contacts were made with providers of mobile PET units. At the same time negotiations were begun with potential FDG suppliers. For the introduction of PET in Estonia mobile truckmounted scanning technology was chosen due to low level of initial investments. Of particular importance was also availability of maintenance personnel from the device providers. A significant prerequisite was potential availability of FDG from the neighbourhood - Finland and Sweden. The latter avoided the necessity for investments into local cyclotrons and local FDG production. For the first scanning experience the dedicated truckmounted PET-camera Accel, Siemens was brought by the International Hospital Group (IHG, Amersfoort, Netherlands). The device arrived by ferry from Stockholm to Tallinn harbour at 10 o'clock in the morning and left by ferry for Helsinki at 23 o'clock. The team-on-truck consisted of one technician for device operation, two drivers and two company representatives. North Estonia Regional Hospital provided three additional technicians for patient preparation and FDG injection, one nuclear medicine doctor and one specialist of biomedical engineering and medical physics. The FDG was provided by MAP Medical Technologies, Schering, Helsinki, Finland. The shipments were made by air. This was possible due to small distance between Tallinn and Helsinki of approximately 80 km due to the regular flight connections between the two cities. The FDG was shipped in two lots with a time interval of 4 hours. The patient selection was based on clinical and histopathology data. In all six patients the exam was justified for detailied staging and

  11. Infrared thermal annealing device

    Gladys, M.J.; Clarke, I.; O'Connor, D.J.

    2003-01-01

    A device for annealing samples within an ultrahigh vacuum (UHV) scanning tunneling microscopy system was designed, constructed, and tested. The device is based on illuminating the sample with infrared radiation from outside the UHV chamber with a tungsten projector bulb. The apparatus uses an elliptical mirror to focus the beam through a sapphire viewport for low absorption. Experiments were conducted on clean Pd(100) and annealing temperatures in excess of 1000 K were easily reached

  12. Development of Scanning-Imaging X-Ray Microscope for Quantitative Three-Dimensional Phase Contrast Microimaging

    Takeuchi, Akihisa; Suzuki, Yoshio; Uesugi, Kentaro

    2013-01-01

    A novel x-ray microscope system has been developed for the purpose of quantitative and sensitive three-dimensional (3D) phase-contrast x-ray microimaging. The optical system is a hybrid that consists of a scanning microscope optics with a one-dimensional (1D) focusing (line-focusing) device and an imaging microscope optics with a 1D objective. These two optics are orthogonally arranged regarding their common optical axis. Each is used for forming each dimension of two-dimensional (2D) image. The same data acquisition process as that of the scanning microscope system enables quantitative and sensitive x-ray imaging such as phase contrast and absorption contrast. Because a 2D image is measured with only 1D translation scan, much shorter measurement time than that of conventional scanning optics has been realized. By combining a computed tomography (CT) technique, some 3D CT application examples are demonstrated

  13. Scanning Microscopes Using X Rays and Microchannels

    Wang, Yu

    2003-01-01

    Scanning microscopes that would be based on microchannel filters and advanced electronic image sensors and that utilize x-ray illumination have been proposed. Because the finest resolution attainable in a microscope is determined by the wavelength of the illumination, the xray illumination in the proposed microscopes would make it possible, in principle, to achieve resolutions of the order of nanometers about a thousand times as fine as the resolution of a visible-light microscope. Heretofore, it has been necessary to use scanning electron microscopes to obtain such fine resolution. In comparison with scanning electron microscopes, the proposed microscopes would likely be smaller, less massive, and less expensive. Moreover, unlike in scanning electron microscopes, it would not be necessary to place specimens under vacuum. The proposed microscopes are closely related to the ones described in several prior NASA Tech Briefs articles; namely, Miniature Microscope Without Lenses (NPO-20218), NASA Tech Briefs, Vol. 22, No. 8 (August 1998), page 43; and Reflective Variants of Miniature Microscope Without Lenses (NPO-20610), NASA Tech Briefs, Vol. 26, No. 9 (September 2002) page 6a. In all of these microscopes, the basic principle of design and operation is the same: The focusing optics of a conventional visible-light microscope are replaced by a combination of a microchannel filter and a charge-coupled-device (CCD) image detector. A microchannel plate containing parallel, microscopic-cross-section holes much longer than they are wide is placed between a specimen and an image sensor, which is typically the CCD. The microchannel plate must be made of a material that absorbs the illuminating radiation reflected or scattered from the specimen. The microchannels must be positioned and dimensioned so that each one is registered with a pixel on the image sensor. Because most of the radiation incident on the microchannel walls becomes absorbed, the radiation that reaches the

  14. Position display device

    Nishizawa, Yukio.

    1974-01-01

    Object: To provide a device capable of easily and quickly reading mutual mounting relations of control bodies such as control rods mounted on a nuclear reactor and positions to which the control bodies are driven. Structure: A scanning circuit is provided to scan positions of controllably mounted control bodies such as control rods. Values detected by scanning the positions are converted into character signals according to the values and converted into preranked color signals. The character signals and color signals are stored in a memory circuit by synchronous signals in synchronism with the scanning in the scanning circuit. Outputs of the memory circuit are displayed by a display unit such as a color Braun tube in accordance with the synchronous signals to provide color representations according to positions to which control bodies are driven in the same positional relation as the mounting of the control bodies. (Kamimura, M.)

  15. Fundamentals of overlay measurement and inspection using scanning electron-microscope

    Kato, T.; Okagawa, Y.; Inoue, O.; Arai, K.; Yamaguchi, S.

    2013-04-01

    Scanning electron-microscope (SEM) has been successfully applied to CD measurement as promising tools for qualifying and controlling quality of semiconductor devices in in-line manufacturing process since 1985. Furthermore SEM is proposed to be applied to in-die overlay monitor in the local area which is too small to be measured by optical overlay measurement tools any more, when the overlay control limit is going to be stringent and have un-ignorable dependence on device pattern layout, in-die location, and singular locations in wafer edge, etc. In this paper, we proposed new overlay measurement and inspection system to make an effective use of in-line SEM image, in consideration of trade-off between measurement uncertainty and measurement pattern density in each SEM conditions. In parallel, we make it clear that the best hybrid overlay metrology is in considering each tool's technology portfolio.

  16. Laser scanning of experimental solar cells

    Plunkett, B. C.; Lasswell, P. G.

    1980-01-01

    A description is presented of a laser scanning instrument which makes it possible to display and measure the spatial response of a solar cell. Examples are presented to illustrate the use of generated micrographs in the isolation of flaws and features of the cell. The laser scanner system uses a 4 mW, CW helium-neon laser, operating a wavelength of 0.633 micrometers. The beam is deflected by two mirror galvanometers arranged to scan in orthogonal directions. After being focused on the solar cell by the beam focusing lens, the moving light spot raster scans the specimen. The current output of the photovoltaic device under test, as a function of the scan dot position, can be displayed in several modes. The laser scanner has proved to be a very useful diagnostic tool in optimizing the process design of transparent metal film photovoltaic devices on Zn3P2, a relatively new photovoltaic material.

  17. Online correction of scanning probe microscopes with pixel accuracy

    Dirscherl, Kai

    2000-01-01

    of 10 nm and an opening angle of 30.0 °. Even atomic resolution can be achieved. The scan movement of the tip is not linear however. This is caused by the propelling device of the SPM for the scan motion - a piezoelectric ceramic. The two major non-linear responses o f the piezo to the applied control....... The algorithm typically contains 5 - 7 parameters which have to be calibrated manually. Still, non-linear errors remain in the order of 1-2%. One pixel in a 512x 512 image corresponds to 0.2% per direction. This goal of measurement accuracy i s reached with the algorithm developed in this thesis. Three...... different SPM are analyzed for their non-linearity. Two commercial tube sc anners are applied with a maximum scan range in x and y of 40.0 µm and 160.0 µm as well as one specially designed stack scanner with a maximum range of 5.0 µm. For the tube scanners, a 1-dimensional line pattern with a reference...

  18. A proton microbeam deflection system to scan target surfaces

    Heck, D.

    1978-12-01

    A system to deflect the proton beam within the Karlsruhe microbeam setup is described. The deflection is achieved whithin a transverse electrical field generated between parallel electrodes. Their tension is controlled by a pattern generator, thus enabling areal and line scans with a variable number of scan points at variable scan speed. The application is demonstrated at two different examples. (orig.) [de

  19. Radiopharmaceutical scanning agents

    1976-01-01

    This invention is directed to dispersions useful in preparing radiopharmaceutical scanning agents, to technetium labelled dispersions, to methods for preparing such dispersions and to their use as scanning agents

  20. Thyroid Scan and Uptake

    Full Text Available ... Scan and Uptake Thyroid scan and uptake uses small amounts of radioactive materials called radiotracers, a special ... is a branch of medical imaging that uses small amounts of radioactive material to diagnose and determine ...

  1. Nuclear Heart Scan

    ... Home / Nuclear Heart Scan Nuclear Heart Scan Also known as Nuclear Stress Test , ... Learn More Connect With Us Contact Us Directly Policies Privacy Policy Freedom of Information Act (FOIA) Accessibility ...

  2. Thyroid Scan and Uptake

    Full Text Available ... of page What will I experience during and after the procedure? Most thyroid scan and thyroid uptake ... you otherwise, you may resume your normal activities after your nuclear medicine scan. If any special instructions ...

  3. RBC nuclear scan

    ... page: //medlineplus.gov/ency/article/003835.htm RBC nuclear scan To use the sharing features on this page, please enable JavaScript. An RBC nuclear scan uses small amounts of radioactive material to ...

  4. Scanning gamma camera

    Engdahl, L.W.; Batter, J.F. Jr.; Stout, K.J.

    1977-01-01

    A scanning system for a gamma camera providing for the overlapping of adjacent scan paths is described. A collimator mask having tapered edges provides for a graduated reduction in intensity of radiation received by a detector thereof, the reduction in intensity being graduated in a direction normal to the scanning path to provide a blending of images of adjacent scan paths. 31 claims, 15 figures

  5. Operational results for the raster scanning power supply system constructed at the Bevalac Biomedical Facility

    Stover, G.; Halliwell, J.; Nyman, M.; Dwinell, R.

    1989-03-01

    A raster scanning power supply for controlling an 8.0 Tesla-meter relativistic heavy-ion beam at the Biomedical Facility has been recently completed and is undergoing electrical testing before on- line operation in 1989. The scanner system will provide tightly controlled beam uniformity and off-axis treatment profiles with large aspect ratios and unusual dimensions. This article will discuss original specifications, agreement with measured results and special device performance (i.e. GTOs, FET actuator assembly, etc.). 5 refs., 4 figs

  6. Adaptive and robust statistical methods for processing near-field scanning microwave microscopy images.

    Coakley, K J; Imtiaz, A; Wallis, T M; Weber, J C; Berweger, S; Kabos, P

    2015-03-01

    Near-field scanning microwave microscopy offers great potential to facilitate characterization, development and modeling of materials. By acquiring microwave images at multiple frequencies and amplitudes (along with the other modalities) one can study material and device physics at different lateral and depth scales. Images are typically noisy and contaminated by artifacts that can vary from scan line to scan line and planar-like trends due to sample tilt errors. Here, we level images based on an estimate of a smooth 2-d trend determined with a robust implementation of a local regression method. In this robust approach, features and outliers which are not due to the trend are automatically downweighted. We denoise images with the Adaptive Weights Smoothing method. This method smooths out additive noise while preserving edge-like features in images. We demonstrate the feasibility of our methods on topography images and microwave |S11| images. For one challenging test case, we demonstrate that our method outperforms alternative methods from the scanning probe microscopy data analysis software package Gwyddion. Our methods should be useful for massive image data sets where manual selection of landmarks or image subsets by a user is impractical. Published by Elsevier B.V.

  7. High-pressure differential scanning microcalorimeter.

    Senin, A A; Dzhavadov, L N; Potekhin, S A

    2016-03-01

    A differential scanning microcalorimeter for studying thermotropic conformational transitions of biopolymers at high pressure has been designed. The calorimeter allows taking measurements of partial heat capacity of biopolymer solutions vs. temperature at pressures up to 3000 atm. The principles of operation of the device, methods of its calibration, as well as possible applications are discussed.

  8. Scanning For Hotspots In Lamp Filaments

    Powers, Charles E.; Van Sant, Tim; Leidecker, Henning

    1993-01-01

    Scanning photometer designed for use in investigation of failures of incandescent lamp filaments. Maps brightness as function of position along each filament to identify bright (hot) spots, occurring at notches and signifying incipient breaks or rewelds. Also used to measure nonuniformity in outputs of such linear devices as light-emitting diodes, and to measure diffraction patterns of lenses.

  9. Thyroid Scan and Uptake

    Full Text Available ... are detected by a special camera or imaging device that produces pictures and provides molecular information. The ... camera. A probe is a small hand-held device resembling a microphone that can detect and measure ...

  10. A new ultrasensitive scanning calorimeter.

    Plotnikov, V V; Brandts, J M; Lin, L N; Brandts, J F

    1997-08-01

    A new ultrasensitive differential scanning calorimeter is described, having a number of novel features arising from integration between hardware and software. It is capable of high performance in either a scanning or isothermal mode of operation. Upscanning is carried out adiabatically while downscanning is nonadiabatic. By using software-controlled signals sent continuously to appropriate hardware devices, it is possible to improve adiabaticity and constancy of scan rate through use of empirical prerun information stored in memory rather than by using feedback systems which respond in real time and generate thermal noise. Also, instrument response time is software-selectable, maximizing performance for both slow- and fast-transient systems. While these and other sophisticated functionalities have been introduced into the instrument to improve performance and data analysis, they are virtually invisible and add no additional complexities into operation of the instrument. Noise and baseline repeatability are an order of magnitude better than published raw data from other instruments so that high-quality results can be obtained on protein solutions, for example, using as little as 50 microg of protein in the sample cell.

  11. Lung PET scan

    ... Chest PET scan; Lung positron emission tomography; PET - chest; PET - lung; PET - tumor imaging; ... Grainger & Allison's Diagnostic Radiology: A Textbook of Medical Imaging . 6th ed. Philadelphia, ...

  12. Scanning of bone metastases

    Robillard, J.

    1977-01-01

    The Centers against cancer of Caen, Angers, Montpellier, Strasbourg and 'the Curie Foundation' have confronted their experience in detection of bone metastases by total body scanning. From the investigation by this procedure, of 1,467 patients with cancer, it results: the confrontation between radio and scanning shows a rate of false positive and false negative identical to the literature ones; the countage scanning allows to reduce the number of false positive; scanning allows to direct bone biopsy and to improve efficiency of histological examination [fr

  13. Strain distribution analysis in Si/SiGe line structures for CMOS technology using Raman spectroscopy

    Hecker, M; Roelke, M; Hermann, P; Zschech, E; Vartanian, V

    2010-01-01

    Strained silicon underneath the field-effect transistor gate increases significantly the charge carrier mobility and thus improves the performance of leading-edge Complementary Metal Oxide Semiconductor (CMOS) devices. For better understanding of the structure-strain relationship on the nanoscale and for optimization of device structures, the measurement of the local strain state has become essential. Raman spectroscopy is used in the present investigation to analyze the strain distribution in and close to silicon/embedded silicon-germanium (SiGe) line structures in conjunction with strain modeling applying finite element analysis. Both experimental results and modeling indicate the impact of geometry on the stress state. An increase of compressive stress within the Si lines is obtained for increasing SiGe line widths and decreasing Si line widths. The stress state within the Si lines is shown to be a mixed one deviating from a pure uniaxial state. Underneath the SiGe cavities, the presence of a tensile stress was observed. To investigate a procedure to scale down the spatial resolution of the Raman measurements, tip-enhanced Raman scattering experiments have been performed on free-standing SiGe lines with 100nm line width and line distance. The results show superior resolution and strain information not attainable in conventional Raman scans.

  14. Control rod drive hydraulic device

    Takekawa, Toru.

    1994-01-01

    The device of the present invention can reliably prevent a possible erroneous withdrawal of control rod driving mechanism when the pressure of a coolant line is increased by isolation operation of hydraulic control units upon periodical inspection for a BWR type reactor. That is, a coolant line is connected to the downstream of a hydraulic supply device. The coolant line is connected to a hydraulic control unit. A coolant hydraulic detection device and a pressure setting device are disposed to the coolant line. A closing signal line and a returning signal line are disposed, which connect the hydraulic supply device and a flow rate control valve for the hydraulic setting device. In the device of the present invention, even if pressure of supplied coolants is elevated due to isolation of hydraulic control units, the elevation of the hydraulic pressure can be prevented. Accordingly, reliability upon periodical reactor inspection can be improved. Further, the facility is simplified and the installation to an existent facility is easy. (I.S.)

  15. PINPIN a-Si:H based structures for X-ray image detection using the laser scanning technique

    Fernandes, M., E-mail: mfernandes@isel.pt [Electronics Telecommunication and Computer Dept., ISEL, R.Conselheiro Emídio Navarro, 1959-007 Lisboa (Portugal); CTS-UNINOVA Quinta da Torre, Monte da Caparica, 2829-516 Caparica (Portugal); Vygranenko, Y.; Vieira, M. [Electronics Telecommunication and Computer Dept., ISEL, R.Conselheiro Emídio Navarro, 1959-007 Lisboa (Portugal); CTS-UNINOVA Quinta da Torre, Monte da Caparica, 2829-516 Caparica (Portugal)

    2015-05-01

    Highlights: • We present novel structure for X-ray image sensor based on the laser scanned technique. • Amorphous silicon based tandem structure characterization results are presented and discussed. • Results from preliminary tests of the imaging application are promising for very large area image sensing. - Abstract: Conventional film based X-ray imaging systems are being replaced by their digital equivalents. Different approaches are being followed by considering direct or indirect conversion, with the later technique dominating. The typical, indirect conversion, X-ray panel detector uses a phosphor for X-ray conversion coupled to a large area array of amorphous silicon based optical sensors and a couple of switching thin film transistors (TFT). The pixel information can then be readout by switching the correspondent line and column transistors, routing the signal to an external amplifier. In this work we follow an alternative approach, where the electrical switching performed by the TFT is replaced by optical scanning using a low power laser beam and a sensing/switching PINPIN structure, thus resulting in a simpler device. The optically active device is a PINPIN array, sharing both front and back electrical contacts, deposited over a glass substrate. During X-ray exposure, each sensing side photodiode collects photons generated by the scintillator screen (560 nm), charging its internal capacitance. Subsequently a laser beam (445 nm) scans the switching diodes (back side) retrieving the stored charge in a sequential way, reconstructing the image. In this paper we present recent work on the optoelectronic characterization of the PINPIN structure to be incorporated in the X-ray image sensor. The results from the optoelectronic characterization of the device and the dependence on scanning beam parameters are presented and discussed. Preliminary results of line scans are also presented.

  16. New Snail Mail Scanning Service

    2012-01-01

    Modernisation does not stop at the CERN postal service (GS/PS). “With more and more digitisation and the prevalence of e-mail throughout the site, we were hoping to provide more timely delivery of letters and make further saving in resources”, said Tueri Datta, head of GS/PS.   Instead of the standard delivery to your P.O. box, the CERN postal service will digitally scan all letters and books up to 100 pages on reception. These scans will subsequently be sent via e-mail to the corresponding recipient as PDF (Portable Data Format - you will need to install “Acrobat Reader” on your PC). Express mail will be handled with priority. Users without a valid CERN mailbox can register at mail.scan.service@cern.ch in order to have their letters read to them via the phone line (we are currently investigating whether we can use the voices of the last five DGs).   This service will start on 1st April 2012 on the Meyrin site and will gradually replace th...

  17. Model PET Scan Activity

    Strunk, Amber; Gazdovich, Jennifer; Redouté, Oriane; Reverte, Juan Manuel; Shelley, Samantha; Todorova, Vesela

    2018-05-01

    This paper provides a brief introduction to antimatter and how it, along with other modern physics topics, is utilized in positron emission tomography (PET) scans. It further describes a hands-on activity for students to help them gain an understanding of how PET scans assist in detecting cancer. Modern physics topics provide an exciting way to introduce students to current applications of physics.

  18. Scanning laser Doppler vibrometry

    Brøns, Marie; Thomsen, Jon Juel

    With a Scanning Laser Doppler Vibrometer (SLDV) a vibrating surface is automatically scanned over predefined grid points, and data processed for displaying vibration properties like mode shapes, natural frequencies, damping ratios, and operational deflection shapes. Our SLDV – a PSV-500H from...

  19. Thyroid Scan and Uptake

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Thyroid Scan and Uptake Thyroid scan and uptake uses ...

  20. The innominate line

    Whelan, M.A.; Myung, K.H.; Bergeron, R.T.

    1984-01-01

    The innominate line continues to be of value in evaluating the integrity of the sphenoid bone since plain skull radiographs remain a primary screening tool for metastatic disease, seizure disorder and headache. The detection of lesions involving the sphenoid bone can be difficult. The accuracy of the radionulcide scan is reduced because of confusion caused by uptake in the adjacent nasal and sinus mucosa. On computed tomography, the sections through the base of the skull and orbit can contain many artifictual densities caused by a combination of bone, soft tissue and sinus air interfaces. In addition, routine settings of window width and level on CT scan are designed to best demonstrate the soft tissues, and bony lesions can easily be missed. Thus, disruption of the ''integrity'' of this line on plain films, particularly the Caldwell projection, can be a sensitive first indicator of disease involving the sphenoid bone. Such a determination on plain film leads to more accurate CT scanning, in that attention will be given to the skull base and scans will be imaged with both soft tissue and bone windows. (orig./MG)

  1. Transverse section scanning mechanism

    Doherty, E.J.

    1978-01-01

    Apparatus is described for scanning a transverse, radionuclide scan-field using an array of focussed collimators. The collimators are movable tangentially on rails, driven by a single motor via a coupled screw. The collimators are also movable in a radial direction on rails driven by a step motor via coupled screws and bevel gears. Adjacent bevel gears rotate in opposite directions so adjacent collimators move in radially opposite directions. In use, the focal point of each collimator scans at least half of the scan-field, e.g. a human head located in the central aperture, and the electrical outputs of detectors associated with each collimator are used to determine the distribution of radioactive emission intensity at a number of points in the scan-field. (author)

  2. Radiographic film digitizing devices

    McFee, W.H.

    1988-01-01

    Until recently, all film digitizing devices for use with teleradiology or picture archiving and communication systems used a video camera to capture an image of the radiograph for subsequent digitization. The development of film digitizers that use a laser beam to scan the film represents a significant advancement in digital technology, resulting in improved image quality compared with video scanners. This paper discusses differences in resolution, efficiency, reliability, and the cost between these two types of devices. The results of a modified receiver operating characteristic comparison study of a video scanner and a laser scanner manufactured by the same company are also discussed

  3. Safe Active Scanning for Energy Delivery Systems Final Report

    Helms, J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Salazar, B. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Scheibel, P. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Engels, M. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Reiger, C. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-09-30

    The Department of Energy’s Cybersecurity for Energy Delivery Systems Program has funded Safe(r) Active Scanning for Energy Delivery Systems, led by Lawrence Livermore National Laboratory, to investigate and analyze the impacts of active scanning in the operational environment of energy delivery systems. In collaboration with Pacific Northwest National Laboratory and Idaho National Laboratory, active scans across three testbeds including 38 devices were performed. This report gives a summary of the initial literature survey performed on the SASEDS project as well as industry partner interview summaries and main findings from Phase 1 of the project. Additionally, the report goes into the details of scanning techniques, methodologies for testing, testbed descriptions, and scanning results, with appendices to elaborate on the specific scans that were performed. As a result of testing, a single device out of 38 exhibited problems when actively scanned, and a reboot was required to fix it. This single failure indicates that active scanning is not likely to have a detrimental effect on the safety and resilience of energy delivery systems. We provide a path forward for future research that could enable wide adoption of active scanning and lead utilities to incorporate active scanning as part of their default network security plans to discover and rectify rogue devices, adversaries, and services that may be on the network. This increased network visibility will allow operational technology cybersecurity practitioners to improve their situational awareness of networks and their vulnerabilities.

  4. Fragment capture device

    Payne, Lloyd R.; Cole, David L.

    2010-03-30

    A fragment capture device for use in explosive containment. The device comprises an assembly of at least two rows of bars positioned to eliminate line-of-sight trajectories between the generation point of fragments and a surrounding containment vessel or asset. The device comprises an array of at least two rows of bars, wherein each row is staggered with respect to the adjacent row, and wherein a lateral dimension of each bar and a relative position of each bar in combination provides blockage of a straight-line passage of a solid fragment through the adjacent rows of bars, wherein a generation point of the solid fragment is located within a cavity at least partially enclosed by the array of bars.

  5. Scanning tunnel microscope with large vision field compatible with a scanning electron microscope

    Volodin, A.P.; Stepanyan, G.A.; Khajkin, M.S.; Ehdel'man, V.S.

    1989-01-01

    A scanning tunnel microscope (STM) with the 20μm vision field and 1nm resolution, designed to be compatible with a scanning electron microscope (SEM), is described. The sample scanning area is chosen within the 3x10mm limits with a 0.1-1μm step. The STM needle is moved automatically toward the sample surface from the maximum distance of 10mm until the tunneling current appears. Bimorphous elements of the KP-1 piezocorrector are used in the STM design. The device is installed on a table of SEM object holders

  6. Laser Scanning in Forests

    Håkan Olsson

    2012-09-01

    Full Text Available The introduction of Airborne Laser Scanning (ALS to forests has been revolutionary during the last decade. This development was facilitated by combining earlier ranging lidar discoveries [1–5], with experience obtained from full-waveform ranging radar [6,7] to new airborne laser scanning systems which had components such as a GNSS receiver (Global Navigation Satellite System, IMU (Inertial Measurement Unit and a scanning mechanism. Since the first commercial ALS in 1994, new ALS-based forest inventory approaches have been reported feasible for operational activities [8–12]. ALS is currently operationally applied for stand level forest inventories, for example, in Nordic countries. In Finland alone, the adoption of ALS for forest data collection has led to an annual savings of around 20 M€/year, and the work is mainly done by companies instead of governmental organizations. In spite of the long implementation times and there being a limited tradition of making changes in the forest sector, laser scanning was commercially and operationally applied after about only one decade of research. When analyzing high-ranked journal papers from ISI Web of Science, the topic of laser scanning of forests has been the driving force for the whole laser scanning research society over the last decade. Thus, the topic “laser scanning in forests” has provided a significant industrial, societal and scientific impact. [...

  7. Bone scan in pediatrics

    Gordon, I.; Peters, A.M.

    1987-01-01

    In 1984, a survey carried out in 21 countries in Europe showed that bone scintigraphy comprised 16% of all paediatric radioisotope scans. Although the value of bone scans in paediatrics is potentially great, their quality varies greatly, and poor-quality images are giving this valuable technique a bad reputation. The handling of children requires a sensitive staff and the provision of a few simple inexpensive items of distraction. Attempting simply to scan a child between two adult patients in a busy general department is a recipe for an unhappy, uncooperative child with the probable result of poor images. The intravenous injection of isotope should be given adjacent to the gamma camera room, unless dynamic scans are required, so that the child does not associate the camera with the injection. This injection is best carried out by someone competent in paediatric venipunture; the entire procedure should be explained to the child and parent, who should remain with child throughout. It is naive to think that silence makes for a cooperative child. The sensitivity of bone-seeking radioisotope tracers and the marked improvement in gamma camera resolution has allowed the bone scanning to become an integrated technique in the assessment of children suspected of suffering from pathological bone conditions. The tracer most commonly used for routine bone scanning is 99m Tc diphosphonate (MDP); other isotopes used include 99m Tc colloid for bone marrow scans and 67 Ga citrate and 111 In white blood cells ( 111 In WBC) for investigation of inflammatory/infective lesions

  8. Full cycle rapid scan EPR deconvolution algorithm.

    Tseytlin, Mark

    2017-08-01

    Rapid scan electron paramagnetic resonance (RS EPR) is a continuous-wave (CW) method that combines narrowband excitation and broadband detection. Sinusoidal magnetic field scans that span the entire EPR spectrum cause electron spin excitations twice during the scan period. Periodic transient RS signals are digitized and time-averaged. Deconvolution of absorption spectrum from the measured full-cycle signal is an ill-posed problem that does not have a stable solution because the magnetic field passes the same EPR line twice per sinusoidal scan during up- and down-field passages. As a result, RS signals consist of two contributions that need to be separated and postprocessed individually. Deconvolution of either of the contributions is a well-posed problem that has a stable solution. The current version of the RS EPR algorithm solves the separation problem by cutting the full-scan signal into two half-period pieces. This imposes a constraint on the experiment; the EPR signal must completely decay by the end of each half-scan in order to not be truncated. The constraint limits the maximum scan frequency and, therefore, the RS signal-to-noise gain. Faster scans permit the use of higher excitation powers without saturating the spin system, translating into a higher EPR sensitivity. A stable, full-scan algorithm is described in this paper that does not require truncation of the periodic response. This algorithm utilizes the additive property of linear systems: the response to a sum of two inputs is equal the sum of responses to each of the inputs separately. Based on this property, the mathematical model for CW RS EPR can be replaced by that of a sum of two independent full-cycle pulsed field-modulated experiments. In each of these experiments, the excitation power equals to zero during either up- or down-field scan. The full-cycle algorithm permits approaching the upper theoretical scan frequency limit; the transient spin system response must decay within the scan

  9. Photovoltaic device

    Reese, Jason A; Keenihan, James R; Gaston, Ryan S; Kauffmann, Keith L; Langmaid, Joseph A; Lopez, Leonardo; Maak, Kevin D; Mills, Michael E; Ramesh, Narayan; Teli, Samar R

    2017-03-21

    The present invention is premised upon an improved photovoltaic device ("PV device"), more particularly to an improved photovoltaic device with a multilayered photovoltaic cell assembly and a body portion joined at an interface region and including an intermediate layer, at least one interconnecting structural member, relieving feature, unique component geometry, or any combination thereof.

  10. Photovoltaic device

    Reese, Jason A.; Keenihan, James R.; Gaston, Ryan S.; Kauffmann, Keith L.; Langmaid, Joseph A.; Lopez, Leonardo C.; Maak, Kevin D.; Mills, Michael E.; Ramesh, Narayan; Teli, Samar R.

    2015-06-02

    The present invention is premised upon an improved photovoltaic device ("PV device"), more particularly to an improved photovoltaic device with a multilayered photovoltaic cell assembly and a body portion joined at an interface region and including an intermediate layer, at least one interconnecting structural member, relieving feature, unique component geometry, or any combination thereof.

  11. Photovoltaic device

    Reese, Jason A.; Keenihan, James R.; Gaston, Ryan S.; Kauffmann, Keith L.; Langmaid, Joseph A.; Lopez, Leonardo C.; Maak, Kevin D.; Mills, Michael E.; Ramesh, Narayan; Teli, Samar R.

    2015-09-01

    The present invention is premised upon an improved photovoltaic device ("PV device"), more particularly to an improved photovoltaic device (10) with a multilayered photovoltaic cell assembly (100) and a body portion (200) joined at an interface region (410) and including an intermediate layer (500), at least one interconnecting structural member (1500), relieving feature (2500), unique component geometry, or any combination thereof.

  12. Huffman and linear scanning methods with statistical language models.

    Roark, Brian; Fried-Oken, Melanie; Gibbons, Chris

    2015-03-01

    Current scanning access methods for text generation in AAC devices are limited to relatively few options, most notably row/column variations within a matrix. We present Huffman scanning, a new method for applying statistical language models to binary-switch, static-grid typing AAC interfaces, and compare it to other scanning options under a variety of conditions. We present results for 16 adults without disabilities and one 36-year-old man with locked-in syndrome who presents with complex communication needs and uses AAC scanning devices for writing. Huffman scanning with a statistical language model yielded significant typing speedups for the 16 participants without disabilities versus any of the other methods tested, including two row/column scanning methods. A similar pattern of results was found with the individual with locked-in syndrome. Interestingly, faster typing speeds were obtained with Huffman scanning using a more leisurely scan rate than relatively fast individually calibrated scan rates. Overall, the results reported here demonstrate great promise for the usability of Huffman scanning as a faster alternative to row/column scanning.

  13. Thyroid Scan and Uptake

    Full Text Available ... for a thyroid scan is 30 minutes or less. Thyroid Uptake You will be given radioactive iodine ( ... for each thyroid uptake is five minutes or less. top of page What will I experience during ...

  14. Thyroid Scan and Uptake

    Full Text Available ... evaluate changes in the gland following medication use, surgery, radiotherapy or chemotherapy top of page How should ... such as an x-ray or CT scan, surgeries or treatments using iodinated contrast material within the ...

  15. Thyroid Scan and Uptake

    Full Text Available ... abnormal was found, and should not be a cause of concern for you. If you had an ... abnormal was found, and should not be a cause of concern for you. Actual scanning time for ...

  16. Tomographic scanning apparatus

    1981-01-01

    Details are given of a tomographic scanning apparatus, with particular reference to a multiplexer slip ring means for receiving output from the detectors and enabling interfeed to the image reconstruction station. (U.K.)

  17. Tomographic scanning apparatus

    1981-01-01

    Details are presented of a tomographic scanning apparatus, its rotational assembly, and the control and circuit elements, with particular reference to the amplifier and multiplexing circuits enabling detector signal calibration. (U.K.)

  18. Tomographic scanning apparatus

    1981-01-01

    This patent specification relates to a tomographic scanning apparatus using a fan beam and digital output signal, and particularly to the design of the gas-pressurized ionization detection system. (U.K.)

  19. Pediatric CT Scans

    The Radiation Epidemiology Branch and collaborators have initiated a retrospective cohort study to evaluate the relationship between radiation exposure from CT scans conducted during childhood and adolescence and the subsequent development of cancer.

  20. Thyroid Scan and Uptake

    Full Text Available ... which are encased in metal and plastic and most often shaped like a box, attached to a ... will I experience during and after the procedure? Most thyroid scan and thyroid uptake procedures are painless. ...

  1. Heart CT scan

    ... make to decrease the risk of heart disease. Risks Risks of CT scans include: Being exposed to ... urac.org). URAC's accreditation program is an independent audit to verify that A.D.A.M. follows ...

  2. Thyroid Scan and Uptake

    Full Text Available ... eat for several hours before your exam because eating can affect the accuracy of the uptake measurement. ... often unattainable using other imaging procedures. For many diseases, nuclear medicine scans yield the most useful information ...

  3. Thyroid Scan and Uptake

    Full Text Available ... A thyroid scan is a type of nuclear medicine imaging. The radioactive iodine uptake test (RAIU) is ... thyroid function, but does not involve imaging. Nuclear medicine is a branch of medical imaging that uses ...

  4. Thyroid Scan and Uptake

    Full Text Available ... that help physicians diagnose and evaluate medical conditions. These imaging scans use radioactive materials called radiopharmaceuticals or ... or had thyroid cancer. A physician may perform these imaging tests to: determine if the gland is ...

  5. Thyroid Scan and Uptake

    Full Text Available ... Actual scanning time for each thyroid uptake is five minutes or less. top of page What will ... diagnostic procedures have been used for more than five decades, and there are no known long-term ...

  6. Thyroid Scan and Uptake

    Full Text Available ... top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Head and Neck Cancer top ... Scan and Uptake Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ...

  7. Thyroid Scan and Uptake

    Full Text Available ... often unattainable using other imaging procedures. For many diseases, nuclear medicine scans yield the most useful information needed to make a diagnosis or to determine appropriate treatment, if any. Nuclear medicine is less expensive and ...

  8. Thyroid Scan and Uptake

    Full Text Available ... the gamma camera and single-photon emission-computed tomography (SPECT). The gamma camera, also called a scintillation ... high as with other imaging techniques, such as CT or MRI. However, nuclear medicine scans are more ...

  9. Scanning Auger Electron Microscope

    Federal Laboratory Consortium — A JEOL model 7830F field emission source, scanning Auger microscope.Specifications / Capabilities:Ultra-high vacuum (UHV), electron gun range from 0.1 kV to 25 kV,...

  10. Thyroid Scan and Uptake

    Full Text Available ... as an overactive thyroid gland, a condition called hyperthyroidism , cancer or other growths assess the nature of ... an x-ray or CT scan, surgeries or treatments using iodinated contrast material within the last two ...

  11. Thyroid Scan and Uptake

    Full Text Available ... painless. However, during the thyroid scan, you may feel uncomfortable when lying completely still with your head ... When the radiotracer is given intravenously, you will feel a slight pin prick when the needle is ...

  12. Thyroid Scan and Uptake

    Full Text Available ... energy. top of page What are some common uses of the procedure? The thyroid scan is used ... community, you can search the ACR-accredited facilities database . This website does not provide cost information. The ...

  13. Thyroid Scan and Uptake

    Full Text Available ... scan and thyroid uptake provide information about the structure and function of the thyroid. The thyroid is ... computer, create pictures offering details on both the structure and function of organs and tissues in your ...

  14. Body CT (CAT Scan)

    ... a CT scan can be reformatted in multiple planes, and can even generate three-dimensional images. These ... other medical conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or ...

  15. Thyroid Scan and Uptake

    Full Text Available ... the gland following medication use, surgery, radiotherapy or chemotherapy top of page How should I prepare? You ... You will receive specific instructions based on the type of scan you are undergoing. top of page ...

  16. Thyroid Scan and Uptake

    Full Text Available ... Uptake? A thyroid scan is a type of nuclear medicine imaging. The radioactive iodine uptake test (RAIU) ... of thyroid function, but does not involve imaging. Nuclear medicine is a branch of medical imaging that ...

  17. Tomographic scanning apparatus

    1981-01-01

    This patent specification describes a tomographic scanning apparatus, with particular reference to the adjustable fan beam and its collimator system, together with the facility for taking a conventional x-radiograph without moving the patient. (U.K.)

  18. Thyroid Scan and Uptake

    Full Text Available ... exam of any medications you are taking, including vitamins and herbal supplements. You should also inform them ... of scan you are undergoing. top of page What does the equipment look like? The special camera ...

  19. The Scanning Optical Microscope.

    Sheppard, C. J. R.

    1978-01-01

    Describes the principle of the scanning optical microscope and explains its advantages over the conventional microscope in the improvement of resolution and contrast, as well as the possibility of producing a picture from optical harmonies generated within the specimen.

  20. Thyroid Scan and Uptake

    Full Text Available ... the gland following medication use, surgery, radiotherapy or chemotherapy top of page How should I prepare? You ... but is often performed on hospitalized patients as well. Thyroid Scan You will be positioned on an ...

  1. Developments in Scanning Hall Probe Microscopy

    Chouinard, Taras; Chu, Ricky; David, Nigel; Broun, David

    2009-05-01

    Low temperature scanning Hall probe microscopy is a sensitive means of imaging magnetic structures with high spatial resolution and magnetic flux sensitivity approaching that of a Superconducting Quantum Interference Device. We have developed a scanning Hall probe microscope with novel features, including highly reliable coarse positioning, in situ optimization of sensor-sample alignment and capacitive transducers for linear, long range positioning measurement. This has been motivated by the need to reposition accurately above fabricated nanostructures such as small superconducting rings. Details of the design and performance will be presented as well as recent progress towards time-resolved measurements with sub nanosecond resolution.

  2. Determining the resolution of scanning microwave impedance microscopy using atomic-precision buried donor structures

    Scrymgeour, D. A.; Baca, A.; Fishgrab, K.; Simonson, R. J.; Marshall, M.; Bussmann, E.; Nakakura, C. Y.; Anderson, M.; Misra, S.

    2017-11-01

    To quantify the resolution limits of scanning microwave impedance microscopy (sMIM), we created scanning tunneling microscope (STM)-patterned donor nanostructures in silicon composed of 10 nm lines of highly conductive silicon buried under a protective top cap of silicon, and imaged them with sMIM. This dopant pattern is an ideal test of the resolution and sensitivity of the sMIM technique, as it is made with nm-resolution and offers minimal complications from topography convolution. It has been determined that typical sMIM tips can resolve lines down to ∼80 nm spacing, while resolution is independent of tip geometry as extreme tip wear does not change the resolving power, contrary to traditional scanning capacitance microscopy (SCM). Going forward, sMIM is an ideal technique for qualifying buried patterned devices, potentially allowing for quantitative post-fabrication characterization of donor structures, which may be an important tool for the study of atomic-scale transistors and state of the art quantum computation schemes.

  3. Multi-channel electronically scanned cryogenic pressure sensor

    Chapman, John J. (Inventor); Hopson, Purnell, Jr. (Inventor); Kruse, Nancy M. H. (Inventor)

    1995-01-01

    A miniature, multi-channel, electronically scanned pressure measuring device uses electrostatically bonded silicon dies in a multielement array. These dies are bonded at specific sites on a glass, prepatterned substrate. Thermal data is multiplexed and recorded on each individual pressure measuring diaphragm. The device functions in a cryogenic environment without the need of heaters to keep the sensor at constant temperatures.

  4. Reactor shutdown device

    Inoue, Toyokazu.

    1982-01-01

    Purpose: To obtain a highly reliable reactor shutdown device capable of checking its function irrespective of the state whether shutdown or operation in a gas-cooled type reactor. Constitution: A hopper is disposed above a guide tube inserted into the reactor core and particulate neutron absorbers are contained in the hopper. An opening for falling particles is disposed to the bottom of the hopper in opposition to the upper end of the guide pipe and the opening is closed by a plug suspended by way of a weld line so as to be capable of dropping. A power source for supplying electrical current to the weld line is disposed. Accordingly, if the current is supplied to the weld line, the line is cut by welding to fall the plug so that the neutron-absorbing particles fall from the opening into the guide pipe to shutdown the reactor, whereby high reliability is obtained for the operation. (Seki, T.)

  5. Track type ultrasonic inspection device

    Kajiyama, Shigeru; Sasaki, Tsukasa; Takahisa, Kazuo.

    1993-01-01

    The present invention concerns an improvement of a scanning device disposed near an object to be inspected such as a nuclear pressure vessel and having an ultrasonic probe, mounted thereon that travel along a running track. Specifically, one of wheel supports on both sides is attached being secured to the scanning device. The other of the supports is capable of fixing and releasing, as well as providing and releasing pressure to and from wheels upon mounting and detachment. This enables to provide a structure capable of pressing the wheels of the running device to the plane of the track and release thereof. Accordingly, it is possible to improve the running performance, reduce the size and weight and shorten the time for mounting and detachment of the running inspection device. (I.S.)

  6. Dexter: Data Extractor for scanned graphs

    Demleitner, Markus

    2011-12-01

    The NASA Astrophysics Data System (ADS) now holds 1.3 million scanned pages, containing numerous plots and figures for which the original data sets are lost or inaccessible. The availability of scans of the figures can significantly ease the regeneration of the data sets. For this purpose, the ADS has developed Dexter, a Java applet that supports the user in this process. Dexter's basic functionality is to let the user manually digitize a plot by marking points and defining the coordinate transformation from the logical to the physical coordinate system. Advanced features include automatic identification of axes, tracing lines and finding points matching a template.

  7. Estimation of line dimensions in 3D direct laser writing lithography

    Guney, M G; Fedder, G K

    2016-01-01

    Two photon polymerization (TPP) based 3D direct laser writing (3D-DLW) finds application in a wide range of research areas ranging from photonic and mechanical metamaterials to micro-devices. Most common structures are either single lines or formed by a set of interconnected lines as in the case of crystals. In order to increase the fidelity of these structures and reach the ultimate resolution, the laser power and scan speed used in the writing process should be chosen carefully. However, the optimization of these writing parameters is an iterative and time consuming process in the absence of a model for the estimation of line dimensions. To this end, we report a semi-empirical analytic model through simulations and fitting, and demonstrate that it can be used for estimating the line dimensions mostly within one standard deviation of the average values over a wide range of laser power and scan speed combinations. The model delimits the trend in onset of micro-explosions in the photoresist due to over-exposure and of low degree of conversion due to under-exposure. The model guides setting of high-fidelity and robust writing parameters of a photonic crystal structure without iteration and in close agreement with the estimated line dimensions. The proposed methodology is generalizable by adapting the model coefficients to any 3D-DLW setup and corresponding photoresist as a means to estimate the line dimensions for tuning the writing parameters. (paper)

  8. Development of Scanning Ultrafast Electron Microscope Capability.

    Collins, Kimberlee Chiyoko [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Talin, Albert Alec [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Chandler, David W. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Michael, Joseph R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-11-01

    Modern semiconductor devices rely on the transport of minority charge carriers. Direct examination of minority carrier lifetimes in real devices with nanometer-scale features requires a measurement method with simultaneously high spatial and temporal resolutions. Achieving nanometer spatial resolutions at sub-nanosecond temporal resolution is possible with pump-probe methods that utilize electrons as probes. Recently, a stroboscopic scanning electron microscope was developed at Caltech, and used to study carrier transport across a Si p-n junction [ 1 , 2 , 3 ] . In this report, we detail our development of a prototype scanning ultrafast electron microscope system at Sandia National Laboratories based on the original Caltech design. This effort represents Sandia's first exploration into ultrafast electron microscopy.

  9. Selective shielding device for scintiphotography

    Harper, J.W.; Kay, T.D.

    1976-01-01

    A selective shielding device to be used in combination with a scintillation camera is described. The shielding device is a substantially oval-shaped configuration removably secured to the scintillation camera. As a result of this combination scanning of preselected areas of a patient can be rapidly and accurately performed without the requirement of mounting any type of shielding paraphernalia on the patient. 1 claim, 2 drawing figures

  10. Thyroid Scan and Uptake

    Full Text Available ... for several hours before your exam because eating can affect the accuracy of the uptake measurement. Jewelry ... small hand-held device resembling a microphone that can detect and measure the amount of the radiotracer ...

  11. Thyroid Scan and Uptake

    Full Text Available ... small amounts of radioactive materials called radiotracers, a special camera and a computer to provide information about ... emissions from the radiotracer are detected by a special camera or imaging device that produces pictures and ...

  12. Preoperative bone scans

    Charkes, N.D.; Malmud, L.S.; Caswell, T.; Goldman, L.; Hall, J.; Lauby, V.; Lightfoot, W.; Maier, W.; Rosemond, G.

    1975-01-01

    Strontium nitrate Sr-87m bone scans were made preoperatively in a group of women with suspected breast cancer, 35 of whom subsequently underwent radical mastectomy. In 3 of the 35 (9 percent), the scans were abnormal despite the absence of clinical or roentgenographic evidence of metastatic disease. All three patients had extensive axillary lymph node involvement by tumor, and went on to have additional bone metastases, from which one died. Roentgenograms failed to detect the metastases in all three. Occult bone metastases account in part for the failure of radical mastectomy to cure some patients with breast cancer. It is recommended that all candidates for radical mastectomy have a preoperative bone scan. (U.S.)

  13. Sealing device

    Garcia-Crespo, Andres Jose

    2013-12-10

    A sealing device for sealing a gap between a dovetail of a bucket assembly and a rotor wheel is disclosed. The sealing device includes a cover plate configured to cover the gap and a retention member protruding from the cover plate and configured to engage the dovetail. The sealing device provides a seal against the gap when the bucket assemply is subjected to a centrifugal force.

  14. Microfluidic Device

    Tai, Yu-Chong (Inventor); Zheng, Siyang (Inventor); Lin, Jeffrey Chun-Hui (Inventor); Kasdan, Harvey L. (Inventor)

    2017-01-01

    Described herein are particular embodiments relating to a microfluidic device that may be utilized for cell sensing, counting, and/or sorting. Particular aspects relate to a microfabricated device that is capable of differentiating single cell types from dense cell populations. One particular embodiment relates a device and methods of using the same for sensing, counting, and/or sorting leukocytes from whole, undiluted blood samples.

  15. Gauging device

    Qurnell, F.D.; Patterson, C.B.

    1979-01-01

    A gauge supporting device for measuring say a square tube comprises a pair of rods or guides in tension between a pair of end members, the end members being spaced apart by a compression member or members. The tensioned guides provide planes of reference for measuring devices moved therealong on a carriage. The device is especially useful for making on site dimensional measurements of components, such as irradiated and therefore radioactive components, that cannot readily be transported to an inspection laboratory. (UK)

  16. High Line

    Kiib, Hans

    2015-01-01

    At just over 10 meters above street level, the High Line extends three kilometers through three districts of Southwestern Manhattan in New York. It consists of simple steel construction, and previously served as an elevated rail line connection between Penn Station on 34th Street and the many....... The High Line project has been carried out as part of an open conversion strategy. The result is a remarkable urban architectural project, which works as a catalyst for the urban development of Western Manhattan. The greater project includes the restoration and reuse of many old industrial buildings...

  17. Tomographic scanning apparatus

    Abele, M.

    1983-01-01

    A computerized tomographic scanning apparatus suitable for diagnosis and for improving target identification in stereotactic neurosurgery is described. It consists of a base, a source of penetrating energy, a detector which produces scanning signals and detector positioning means. A frame with top and bottom arms secures the detector and source to the top and bottom arms respectively. A drive mechanism rotates the frame about an axis along which the frame may also be moved. Finally, the detector may be moved relative to the bottom arm in a direction contrary to the rotation of the frame. (U.K.)

  18. Scanning the phenomenological MSSM

    Wuerzinger, Jonas

    2017-01-01

    A framework to perform scans in the 19-dimensional phenomenological MSSM is developed and used to re-evaluate the ATLAS experiments' sensitivity to R-parity-conserving supersymmetry with LHC Run 2 data ($\\sqrt{s}=13$ TeV), using results from 14 separate ATLAS searches. We perform a $\\tilde{t}_1$ dedicated scan, only considering models with $m_{\\tilde{t}_1}<1$ TeV, while allowing both a neutralino ($\\tilde{\\chi}_1^0$) and a sneutrino ($\\tilde{\

  19. Calibration of scanning Lidar

    Gómez Arranz, Paula; Courtney, Michael

    This report describes the tests carried out on a scanning lidar at the DTU Test Station for large wind turbines, Høvsøre. The tests were divided in two parts. In the first part, the purpose was to obtain wind speed calibrations at two heights against two cup anemometers mounted on a mast. Additio......This report describes the tests carried out on a scanning lidar at the DTU Test Station for large wind turbines, Høvsøre. The tests were divided in two parts. In the first part, the purpose was to obtain wind speed calibrations at two heights against two cup anemometers mounted on a mast...

  20. Adaptive Optical Scanning Holography

    Tsang, P. W. M.; Poon, Ting-Chung; Liu, J.-P.

    2016-01-01

    Optical Scanning Holography (OSH) is a powerful technique that employs a single-pixel sensor and a row-by-row scanning mechanism to capture the hologram of a wide-view, three-dimensional object. However, the time required to acquire a hologram with OSH is rather lengthy. In this paper, we propose an enhanced framework, which is referred to as Adaptive OSH (AOSH), to shorten the holographic recording process. We have demonstrated that the AOSH method is capable of decreasing the acquisition time by up to an order of magnitude, while preserving the content of the hologram favorably. PMID:26916866

  1. Design and verification of the miniature optical system for small object surface profile fast scanning

    Chi, Sheng; Lee, Shu-Sheng; Huang, Jen, Jen-Yu; Lai, Ti-Yu; Jan, Chia-Ming; Hu, Po-Chi

    2016-04-01

    As the progress of optical technologies, different commercial 3D surface contour scanners are on the market nowadays. Most of them are used for reconstructing the surface profile of mold or mechanical objects which are larger than 50 mm×50 mm× 50 mm, and the scanning system size is about 300 mm×300 mm×100 mm. There are seldom optical systems commercialized for surface profile fast scanning for small object size less than 10 mm×10 mm×10 mm. Therefore, a miniature optical system has been designed and developed in this research work for this purpose. Since the most used scanning method of such system is line scan technology, we have developed pseudo-phase shifting digital projection technology by adopting projecting fringes and phase reconstruction method. A projector was used to project a digital fringe patterns on the object, and the fringes intensity images of the reference plane and of the sample object were recorded by a CMOS camera. The phase difference between the plane and object can be calculated from the fringes images, and the surface profile of the object was reconstructed by using the phase differences. The traditional phase shifting method was accomplished by using PZT actuator or precisely controlled motor to adjust the light source or grating and this is one of the limitations for high speed scanning. Compared with the traditional optical setup, we utilized a micro projector to project the digital fringe patterns on the sample. This diminished the phase shifting processing time and the controlled phase differences between the shifted phases become more precise. Besides, the optical path design based on a portable device scanning system was used to minimize the size and reduce the number of the system components. A screwdriver section about 7mm×5mm×5mm has been scanned and its surface profile was successfully restored. The experimental results showed that the measurement area of our system can be smaller than 10mm×10mm, the precision reached to

  2. Selecting Cells for Bioartificial Liver Devices and the Importance of a 3D Culture Environment: A Functional Comparison between the HepaRG and C3A Cell Lines.

    van Wenum, Martien; Adam, Aziza A A; Hakvoort, Theodorus B M; Hendriks, Erik J; Shevchenko, Valery; van Gulik, Thomas M; Chamuleau, Robert A F M; Hoekstra, Ruurdtje

    2016-01-01

    Recently, the first clinical trials on Bioartificial Livers (BALs) loaded with a proliferative human hepatocyte cell source have started. There are two cell lines that are currently in an advanced state of BAL development; HepaRG and HepG2/C3A. In this study we aimed to compare both cell lines on applicability in BALs and to identify possible strategies for further improvement. We tested both cell lines in monolayer- and BAL cultures on growth characteristics, hepatic differentiation, nitrogen-, carbohydrate-, amino acid- and xenobiotic metabolism. Interestingly, both cell lines adapted the hepatocyte phenotype more closely when cultured in BALs; e.g. monolayer cultures produced lactate, while BAL cultures showed diminished lactate production (C3A) or conversion to elimination (HepaRG), and urea cycle activity increased upon BAL culturing in both cell lines. HepaRG-BALs outperformed C3A-BALs on xenobiotic metabolism, ammonia elimination and lactate elimination, while protein synthesis was comparable. In BAL cultures of both cell lines ammonia elimination correlated positively with glutamine production and glutamate consumption, suggesting ammonia elimination was mainly driven by the balance between glutaminase and glutamine synthetase activity. Both cell lines lacked significant urea cycle activity and both required multiple culture weeks before reaching optimal differentiation in BALs. In conclusion, culturing in BALs enhanced hepatic functionality of both cell lines and from these, the HepaRG cells are the most promising proliferative cell source for BAL application.

  3. Selecting Cells for Bioartificial Liver Devices and the Importance of a 3D Culture Environment: A Functional Comparison between the HepaRG and C3A Cell Lines

    van Wenum, Martien; Adam, Aziza A. A.; Hakvoort, Theodorus B. M.; Hendriks, Erik J.; Shevchenko, Valery; van Gulik, Thomas M.; Chamuleau, Robert A. F. M.; Hoekstra, Ruurdtje

    2016-01-01

    Recently, the first clinical trials on Bioartificial Livers (BALs) loaded with a proliferative human hepatocyte cell source have started. There are two cell lines that are currently in an advanced state of BAL development; HepaRG and HepG2/C3A. In this study we aimed to compare both cell lines on

  4. World lines.

    Waser Jürgen; Fuchs Raphael; Ribicic Hrvoje; Schindler Benjamin; Blöschl Günther; Gröller Eduard

    2010-01-01

    In this paper we present World Lines as a novel interactive visualization that provides complete control over multiple heterogeneous simulation runs. In many application areas decisions can only be made by exploring alternative scenarios. The goal of the suggested approach is to support users in this decision making process. In this setting the data domain is extended to a set of alternative worlds where only one outcome will actually happen. World Lines integrate simulation visualization and...

  5. Thyroid Scan and Uptake

    Full Text Available ... process that regulates the rate at which the body converts food to energy. top of page What are some common uses of the procedure? The thyroid scan is used to determine the size, shape and position of the thyroid gland. The ...

  6. Thyroid Scan and Uptake

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Thyroid Scan and Uptake ...

  7. Dialogue scanning measuring systems

    Borodyuk, V.P.; Shkundenkov, V.N.

    1985-01-01

    The main developments of scanning measuring systems intended for mass precision processsing of films in nuclear physics problems and in related fields are reviewed. A special attention is paid to the problem of creation of dialogue systems which permit to simlify the development of control computer software

  8. Scanning electron microscopy

    Cox, B. [Atomic Energy of Canada Limited, Chalk River, Ontario (Canada)

    1970-05-15

    The JSM-11 scanning electron microscope at CRNL has been used extensively for topographical studies of oxidized metals, fracture surfaces, entomological and biological specimens. A non-dispersive X-ray attachment permits the microanalysis of the surface features. Techniques for the production of electron channeling patterns have been developed. (author)

  9. Scanning tunneling microscopy

    Binnig, G.; Rohrer, H.

    1983-01-01

    Based on vacuum tunneling, a novel type of microscope, the scanning tunneling microscope (STM) was developed. It has an unprecedented resolution in real space on an atomic scale. The authors review the important technical features, illustrate the power of the STM for surface topographies and discuss its potential in other areas of science and technology. (Auth.)

  10. Bone scan in rheumatology

    Morales G, R.; Cano P, R.; Mendoza P, R.

    1993-01-01

    In this chapter a revision is made concerning different uses of bone scan in rheumatic diseases. These include reflex sympathetic dystrophy, osteomyelitis, spondyloarthropaties, metabolic bone diseases, avascular bone necrosis and bone injuries due to sports. There is as well some comments concerning pediatric pathology and orthopedics. (authors). 19 refs., 9 figs

  11. Thyroid Scan and Uptake

    Full Text Available ... information. The thyroid scan and thyroid uptake provide information about the structure and function of the thyroid. The thyroid is a gland in the neck that controls metabolism , a chemical process that regulates the rate at which the body ...

  12. Tomographic scanning apparatus

    1981-01-01

    Details are given of a tomographic scanning apparatus, with particular reference to the means of adjusting the apparent gain of the signal processing means for receiving output signals from the detectors, to compensate for drift in the gain characteristics, including means for passing a reference signal. (U.K.)

  13. Stabilized radiographic scanning agent

    Fawzi, M.B.

    1979-01-01

    A stable composition useful in preparation of technetium-99m-based radiographic scanning agents has been developed. The composition contains a stabilizing amount of gentisate stabilizer selected from gentisic acid and its soluble pharmaceutically-acceptable salts and esthers. (E.G.)

  14. Scanning electron microscope

    Anon.

    1980-01-01

    The principle underlying the design of the scanning electron microscope (SEM), the design and functioning of SEM are described. Its applications in the areas of microcircuitry and materials science are outlined. The development of SEM in India is reviewed. (M.G.B.)

  15. Radiographic scanning agent

    Tofe, A.J.

    1976-01-01

    A stable radiographic scanning agent on a sup(99m)Tc basis has been developed. The substance contains a pertechnetate reduction agent, tin(II)-chloride, chromium(II)-chloride, or iron(II)-sulphate, as well as an organospecific carrier and ascorbic acid or a pharmacologically admissible salt or ester of ascorbic acid. (VJ) [de

  16. Thyroid Scan and Uptake

    Full Text Available ... you: have had any tests, such as an x-ray or CT scan, surgeries or treatments using iodinated ... page How does the procedure work? With ordinary x-ray examinations, an image is made by passing x- ...

  17. Thyroid Scan and Uptake

    Full Text Available ... for a thyroid scan is 30 minutes or less. Thyroid Uptake You will be given radioactive iodine (I-123 or I-131) in liquid or capsule form to swallow. The thyroid uptake will begin several hours to 24 hours later. Often, two separate uptake ...

  18. Thyroid Scan and Uptake

    Full Text Available ... an x-ray or CT scan, surgeries or treatments using iodinated contrast material within the last two months. are taking medications or ingesting other substances that contain iodine , including kelp, seaweed, cough syrups, multivitamins or heart medications. have any ...

  19. Fusion devices

    Fowler, T.K.

    1977-01-01

    Three types of thermonuclear fusion devices currently under development are reviewed for an electric utilities management audience. Overall design features of laser fusion, tokamak, and magnetic mirror type reactors are described and illustrated. Thrusts and trends in current research on these devices that promise to improve performance are briefly reviewed. Twenty photographs and drawings are included

  20. BRAKE DEVICE

    O'Donnell, T.J.

    1959-03-10

    A brake device is described for utilization in connection with a control rod. The device comprises a pair of parallelogram link mechanisms, a control rod moveable rectilinearly therebetween in opposite directions, and shoes resiliently supported by the mechanism for frictional engagement with the control rod.

  1. CS-Studio Scan System Parallelization

    Kasemir, Kay [ORNL; Pearson, Matthew R [ORNL

    2015-01-01

    For several years, the Control System Studio (CS-Studio) Scan System has successfully automated the operation of beam lines at the Oak Ridge National Laboratory (ORNL) High Flux Isotope Reactor (HFIR) and Spallation Neutron Source (SNS). As it is applied to additional beam lines, we need to support simultaneous adjustments of temperatures or motor positions. While this can be implemented via virtual motors or similar logic inside the Experimental Physics and Industrial Control System (EPICS) Input/Output Controllers (IOCs), doing so requires a priori knowledge of experimenters requirements. By adding support for the parallel control of multiple process variables (PVs) to the Scan System, we can better support ad hoc automation of experiments that benefit from such simultaneous PV adjustments.

  2. Evaluating imaging devices

    Rollo, F.D.

    1977-01-01

    The performance of any imaging device depends on two principal factors inherent to the device, namely, plane sensitivity and spatial resolution. These factors may be defined as follows: plane sensitivity is the counts per second recorded by the imaging device for each disintegration per second per square centimeter occurring within a plane sheet of radioactivity. Spatial resolution may be defined as the fidelity with which the imaging device reproduces the activity distribution of an object in the image plane. In all imaging devices, a trade-off exists between these two parameters; that is, as sensitivity improves, spatial resolution is degraded, and vice versa. Therefore, to fully evaluate an imaging system a technique should be selected that measures both parameters and reflects the trade-off between the two. In addition, the method should approximate the clinical problem, namely, the detection of a focal lesion within an activity distribution. Several methods have been described to evaluate nuclear imaging devices. The more common techniques include the use of organ phantoms, bar phantoms, line-spread functions, modulation transfer functions, contrast efficiency functions, and performance index functions. Each of these techniques is briefly described in this chapter, and their advantages and disadvantages are discussed. In addition, a phantom that can be used to simply and completely measure overall imaging system performance is described

  3. Profilographic detection system for single-track scanning device

    Silar, J.; Kula, J.

    1988-01-01

    A profilographic detection system is claimed for diagnosing the renal function by isotope nephrography, and the bladder filling in small children and infants. The configuration described guarantees good position resolution and sensitivity of the detection system. (E.J.). 2 figs

  4. Coordination of Mobile Devices : Technology and Standards Scan.

    2015-06-19

    The connected vehicle environment was envisioned as a means of exchanging messages through a connected vehicle fleet. The majority of the current connected vehicle environment focuses on the vehicle, by supporting the exchange of messages from vehicl...

  5. Effective Dose of Positioning Scans for Five CBCT Devices

    2016-05-25

    entire orthodontic residency. Thank you to my parents, Dan and Sue, for all of their love, babysitting, and holiday gifts over these past two years...identifying patient data and records all user actions. Log files from March 2013 to February 2015 were gathered for inclusion in the study sample

  6. Status of colorectal cancer devices: present scenario.

    Chandel, Shammy; Akhtar, Reyhan; Sarotra, Pooja; Medhi, Bikash

    2015-06-01

    The purpose of this study was the colonoscopic detection and removal of neoplasia from the colorectum to prevent the development of colorectal cancer. Various online medical databases were searched such as PubMed, ACS, NCI, NIH, WHO, etc. for relevant publications and clinical trials for new developments in colonoscopic devices that are intended for diagnostic visualization and therapeutic interventions of the digestive tract. HD colon and I-Scan both has shown to increase the detection of sporadic adenomas with high quality. Third Eye Retroscope confers the backward view of colon, but aeroscope screens the entire colon in 30-60 min. Narrow-band imaging enhances mucosal and vascular details through the color differentiation of precancerous or cancerous polyp, compared to white light colonoscopy. The PillCam Colon Capsule is another new technique which is easily inserted and painless. In case of chemotherapy, Therasphere with Yttrium-90 has good results in the treatment of colorectal adenocarcinoma metastasis. Radiofrequency ablation is a good technique for tumors ablation and Staple Line Reinforcement prevents the leak during and post-surgery of colon. FOBT is much more sensitive and cheaper test for colorectal cancer screening. Registered clinical trials have shown promising results for neoplasia detection by I-Scan, TER, and NBI imaging techniques will change current colonoscopic practice in colorectal cancer screening. However, more studies and inventions are required for improving the patient safety and efficacy.

  7. Apparatus for producing a visual representation of a radiographic scan

    Hounsfield, G.N.

    1976-01-01

    An apparatus is disclosed for providing a visual representation of the absorption or transmission coefficients of the elements of a two dimensional matrix of elements notionally defined in a cross-sectional plane through a body. The representation is in the form of an analogue display comprising superimposed lines of information scanned on the surface of a suitable screen, the brightness of each line being indicative of the absorption suffered by penetrating radiation on traversing a respective path through said plane of the body. The orientation of each scanned line depends on the orientation of the respective path with respect to the body. 7 Claims, 4 Drawing Figures

  8. Digital Processing for Modifying and Rearranging Rectilinear and Section Scan Data under Direct Observation

    Kuhl, D. E.; Edwards, R. Q. [University of Pennsylvania, Philadelphia, PA (United States)

    1969-01-15

    Our digital processor for scan data is an on-site instrument that is intermediate in complexity between conventional optical processing devices and large digital computers. It is designed to provide for a wide and flexible range of secondary data operations, direct picture display on a CRT screen, and full operator control of both processing and display operations at the time of viewing. The instrument does not require the user to learn complicated programing schemes. The operator is expected to be a physician who will control the parameters of interest by punching preset buttons on a keyboard while observing changes displayed on a CRT screen. The system functions primarily as an investigative tool for studying perception of scan information and ways of making this information more meaningful. Data operations include data bounding, spatial averaging, iso-count line generation, image addition and subtraction, and several forms of quantitative read-out for analysis of regional data. The instrument is intended to serve as a central processor and reader for data from several units. Investigations with this processor have served as a source of information leading to the design of more simple processing devices suitable for wider acceptance. For example, the Mark III rectilinear and transverse section brain scanner that has evolved from this project is expected to be a practical improvement of the brain study method. This instrument is designed especially for rapid brain scanning using {sup 99m}Tc pertechnetate. It has a self-contained computer, integrated digital circuits for compactness and economy, and provision for transverse section scanning. The advantages of this system are that it provides a more thorough study using both transverse section and rectilinear modes, rapid performance, precise orientation of section and rectilinear views to the patient position, efficient transfer of information between physician and machine during studies, and economy of design

  9. 67Ga lung scan

    Niden, A.H.; Mishkin, F.S.; Khurana, M.M.L.; Pick, R.

    1977-01-01

    Twenty-three patients with clinical signs of pulmonary embolic disease and lung infiltrates were studied to determine the value of gallium citrate 67 Ga lung scan in differentiating embolic from inflammatory lung disease. In 11 patients without angiographically proved embolism, only seven had corresponding ventilation-perfusion defects compatible with inflammatory disease. In seven of these 11 patients, the 67 Ga concentration indicated inflammatory disease. In the 12 patients with angiographically proved embolic disease, six had corresponding ventilation-perfusion defects compatible with inflammatory disease. None had an accumulation of 67 Ga in the area of pulmonary infiltrate. Thus, ventilation-perfusion lung scans are of limited value when lung infiltrates are present. In contrast, the accumulation of 67 Ga in the lung indicates an inflammatory process. Gallium imaging can help select those patients with lung infiltrates who need angiography

  10. Horizon Scanning for Pharmaceuticals

    Lepage-Nefkens, Isabelle; Douw, Karla; Mantjes, GertJan

    for a joint horizon scanning system (HSS).  We propose to create a central “horizon scanning unit” to perform the joint HS activities (a newly established unit, an existing HS unit, or a third party commissioned and financed by the collaborating countries). The unit will be responsible for the identification...... and filtration of new and emerging pharmaceutical products. It will maintain and update the HS database, organise company pipeline meetings, and disseminate the HSS’s outputs.  The HS unit works closely together with the designated national HS experts in each collaborating country. The national HS experts...... will collect country-specific information, liaise between the central HS unit and country-specific clinical and other experts, coordinate the national prioritization process (to select products for early assessment), and communicate the output of the HSS to national decision makers.  The outputs of the joint...

  11. An atomic force microscopy-based method for line edge roughness measurement

    Fouchier, M.; Pargon, E.; Bardet, B. [CNRS/UJF-Grenoble1/CEA LTM, 17 avenue des Martyrs, 38054 Grenoble cedex 9 (France)

    2013-03-14

    With the constant decrease of semiconductor device dimensions, line edge roughness (LER) becomes one of the most important sources of device variability and needs to be controlled below 2 nm for the future technological nodes of the semiconductor roadmap. LER control at the nanometer scale requires accurate measurements. We introduce a technique for LER measurement based upon the atomic force microscope (AFM). In this technique, the sample is tilted at about 45 Degree-Sign and feature sidewalls are scanned along their length with the AFM tip to obtain three-dimensional images. The small radius of curvature of the tip together with the low noise level of a laboratory AFM result in high resolution images. Half profiles and LER values on all the height of the sidewalls are extracted from the 3D images using a procedure that we developed. The influence of sample angle variations on the measurements is shown to be small. The technique is applied to the study of a full pattern transfer into a simplified gate stack. The images obtained are qualitatively consistent with cross-section scanning electron microscopy images and the average LER values agree with that obtained by critical dimension scanning electron microscopy. In addition to its high resolution, this technique presents several advantages such as the ability to image the foot of photoresist lines, complex multi-layer stacks regardless of the materials, and deep re-entrant profiles.

  12. Silver linings.

    Bultas, Margaret W; Pohlman, Shawn

    2014-01-01

    The purpose of this interpretive phenomenological study was to gain a better understanding of the experiences of 11 mothers of preschool children with autism spectrum disorder (ASD). Mothers were interviewed three times over a 6 week period. Interviews were analyzed using interpretive methods. This manuscript highlights one particular theme-a positive perspective mothers described as the "silver lining." This "silver lining" represents optimism despite the adversities associated with parenting a child with ASD. A deeper understanding of this side of mothering children with ASD may help health care providers improve rapport, communication, and result in more authentic family centered care. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Scanning drop sensor

    Jin, Jian; Xiang, Chengxiang; Gregoire, John

    2017-05-09

    Electrochemical experiments are performed on a collection of samples by suspending a drop of electrolyte solution between an electrochemical experiment probe and one of the samples that serves as a test sample. During the electrochemical experiment, the electrolyte solution is added to the drop and an output solution is removed from the drop. The probe and collection of samples can be moved relative to one another so the probe can be scanned across the samples.

  14. Scanning drop sensor

    Jin, Jian; Xiang, Chengxiang; Gregoire, John M.; Shinde, Aniketa A.; Guevarra, Dan W.; Jones, Ryan J.; Marcin, Martin R.; Mitrovic, Slobodan

    2017-05-09

    Electrochemical or electrochemical and photochemical experiments are performed on a collection of samples by suspending a drop of electrolyte solution between an electrochemical experiment probe and one of the samples that serves as a test sample. During the electrochemical experiment, the electrolyte solution is added to the drop and an output solution is removed from the drop. The probe and collection of samples can be moved relative to one another so the probe can be scanned across the samples.

  15. IMEF gamma scanning system

    Baek, Sang Yeol; Park, Dae Kyu; Ahn, Sang Bok; Ju, Yong Sun; Jeon, Yong Bum

    1997-06-01

    The gamma scanning system which is installed in IMEF is the equipment obtaining the gamma ray spectrum from irradiated fuels. This equipment could afford the useful data relating spent fuels like as burn-up measurements. We describe the specifications of the equipment and its accessories, and also described its operation procedure so that an operator can use this report as the operation procedure. (author). 1 tab., 11 figs., 11 refs.

  16. IMEF gamma scanning system

    Baek, Sang Yeol; Park, Dae Kyu; Ahn, Sang Bok; Ju, Yong Sun; Jeon, Yong Bum.

    1997-06-01

    The gamma scanning system which is installed in IMEF is the equipment obtaining the gamma ray spectrum from irradiated fuels. This equipment could afford the useful data relating spent fuels like as burn-up measurements. We describe the specifications of the equipment and its accessories, and also described its operation procedure so that an operator can use this report as the operation procedure. (author). 1 tab., 11 figs., 11 refs

  17. Wireless device connection problems and design solutions

    Song, Ji-Won; Norman, Donald; Nam, Tek-Jin; Qin, Shengfeng

    2016-09-01

    Users, especially the non-expert users, commonly experience problems when connecting multiple devices with interoperability. While studies on multiple device connections are mostly concentrated on spontaneous device association techniques with a focus on security aspects, the research on user interaction for device connection is still limited. More research into understanding people is needed for designers to devise usable techniques. This research applies the Research-through-Design method and studies the non-expert users' interactions in establishing wireless connections between devices. The "Learning from Examples" concept is adopted to develop a study focus line by learning from the expert users' interaction with devices. This focus line is then used for guiding researchers to explore the non-expert users' difficulties at each stage of the focus line. Finally, the Research-through-Design approach is used to understand the users' difficulties, gain insights to design problems and suggest usable solutions. When connecting a device, the user is required to manage not only the device's functionality but also the interaction between devices. Based on learning from failures, an important insight is found that the existing design approach to improve single-device interaction issues, such as improvements to graphical user interfaces or computer guidance, cannot help users to handle problems between multiple devices. This study finally proposes a desirable user-device interaction in which images of two devices function together with a system image to provide the user with feedback on the status of the connection, which allows them to infer any required actions.

  18. A search for spectral lines in gamma-ray bursts using TGRS

    Kurczynski, P.; Palmer, D.; Seifert, H.; Teegarden, B. J.; Gehrels, N.; Cline, T. L.; Ramaty, R.; Hurley, K.; Madden, N. W.; Pehl, R. H.

    1998-01-01

    We present the results of an ongoing search for narrow spectral lines in gamma-ray burst data. TGRS, the Transient Gamma-Ray Spectrometer aboard the Wind satellite is a high energy-resolution Ge device. Thus it is uniquely situated among the array of space-based, burst sensitive instruments to look for line features in gamma-ray burst spectra. Our search strategy adopts a two tiered approach. An automated 'quick look' scan searches spectra for statistically significant deviations from the continuum. We analyzed all possible time accumulations of spectra as well as individual spectra for each burst. Follow-up analysis of potential line candidates uses model fitting with F-test and χ 2 tests for statistical significance

  19. Sealing devices

    Coulson, R.A.

    1980-01-01

    A sealing device for minimising the leakage of toxic or radioactive contaminated environments through a biological shield along an opening through which a flexible component moves that penetrates the shield. The sealing device comprises an outer tubular member which extends over a length not less than the maximum longitudinal movement of the component along the opening. An inner sealing block is located intermediate the length of the component by connectors and is positioned in the bore of the outer tubular member to slide in the bore and effect a seal over the entire longitudinal movement of the component. The cross-section of the device may be circular and the block may be of polytetrafluoroethylene or of nylon impregnated with molybdenum or may be metallic. A number of the sealing devices may be combined into an assembly for a plurality of adjacent longitudinally movable components, each adapted to sustain a tensile load, providing the various drives of a master-slave manipulator. (author)

  20. Ferroelectric devices

    Uchino, Kenji

    2009-01-01

    Updating its bestselling predecessor, Ferroelectric Devices, Second Edition assesses the last decade of developments-and setbacks-in the commercialization of ferroelectricity. Field pioneer and esteemed author Uchino provides insight into why this relatively nascent and interdisciplinary process has failed so far without a systematic accumulation of fundamental knowledge regarding materials and device development.Filling the informational void, this collection of information reviews state-of-the-art research and development trends reflecting nano and optical technologies, environmental regulat

  1. Implementation of synthetic aperture imaging on a hand-held device

    Hemmsen, Martin Christian; Kjeldsen, Thomas; Larsen, Lee

    2014-01-01

    -held devices all with different chipsets and a BK Medical UltraView 800 ultrasound scanner emulating a wireless probe. The wireless transmission is benchmarked using an imaging setup consisting of 269 scan lines x 1472 complex samples (1.58 MB pr. frame, 16 frames per second). The measured data throughput...... reached an average of 28.8 MB/s using a LG G2 mobile device, which is more than the required data throughput of 25.3 MB/s. Benchmarking the processing performance for B-mode imaging showed a total processing time of 18.9 ms (53 frames/s), which is less than the acquisition time (62.5 ms).......This paper presents several implementations of Syn- thetic Aperture Sequential Beamforming (SASB) on commer- cially available hand-held devices. The implementations include real-time wireless reception of ultrasound radio frequency sig- nals and GPU processing for B-mode imaging. The proposed...

  2. Topological Acoustic Delay Line

    Zhang, Zhiwang; Tian, Ye; Cheng, Ying; Wei, Qi; Liu, Xiaojun; Christensen, Johan

    2018-03-01

    Topological protected wave engineering in artificially structured media is at the frontier of ongoing metamaterials research that is inspired by quantum mechanics. Acoustic analogues of electronic topological insulators have recently led to a wealth of new opportunities in manipulating sound propagation with strikingly unconventional acoustic edge modes immune to backscattering. Earlier fabrications of topological insulators are characterized by an unreconfigurable geometry and a very narrow frequency response, which severely hinders the exploration and design of useful devices. Here we establish topologically protected sound in reconfigurable phononic crystals that can be switched on and off simply by rotating its three-legged "atoms" without altering the lattice structure. In particular, we engineer robust phase delay defects that take advantage of the ultrabroadband reflection-free sound propagation. Such topological delay lines serve as a paradigm in compact acoustic devices, interconnects, and electroacoustic integrated circuits.

  3. Automatic Ultrasound Scanning

    Moshavegh, Ramin

    on the user adjustments on the scanner interface to optimize the scan settings. This explains the huge interest in the subject of this PhD project entitled “AUTOMATIC ULTRASOUND SCANNING”. The key goals of the project have been to develop automated techniques to minimize the unnecessary settings...... on the scanners, and to improve the computer-aided diagnosis (CAD) in ultrasound by introducing new quantitative measures. Thus, four major issues concerning automation of the medical ultrasound are addressed in this PhD project. They touch upon gain adjustments in ultrasound, automatic synthetic aperture image...

  4. Radiographic scanning agent

    Bevan, J.A.

    1983-01-01

    This invention relates to radiodiagnostic agents and more particularly to a composition and method for preparing a highly effective technetium-99m-based bone scanning agent. One deficiency of x-ray examination is the inability of that technique to detect skeletal metastases in their incipient stages. It has been discovered that the methanehydroxydiphosphonate bone mineral-seeking agent is unique in that it provides the dual benefits of sharp radiographic imaging and excellent lesion detection when used with technetium-99m. This agent can also be used with technetium-99m for detecting soft tissue calcification in the manner of the inorganic phosphate radiodiagnostic agents

  5. Spinal CT scan, 1

    Nakagawa, Hiroshi

    1982-01-01

    Methods of CT of the cervical and thoracic spines were explained, and normal CT pictures of them were described. Spinal CT was evaluated in comparison with other methods in various spinal diseases. Plain CT revealed stenosis due to spondylosis or ossification of posterior longitudinal ligament and hernia of intervertebral disc. CT took an important role in the diagnosis of spinal cord tumors with calcification and destruction of the bone. CT scan in combination with other methods was also useful for the diagnosis of spinal injuries, congenital anomalies and infections. (Ueda, J.)

  6. Scanning Color Laser Microscope

    Awamura, D.; Ode, T.; Yonezawa, M.

    1988-01-01

    A confocal color laser microscope which utilizes a three color laser light source (Red: He-Ne, Green: Ar, Blue: Ar) has been developed and is finding useful applications in the semiconductor field. The color laser microscope, when compared to a conventional microscope, offers superior color separation, higher resolution, and sharper contrast. Recently some new functions including a Focus Scan Memory, a Surface Profile Measurement System, a Critical Dimension Measurement system (CD) and an Optical Beam Induced Current Function (OBIC) have been developed for the color laser microscope. This paper will discuss these new features.

  7. Scanning apparatus and method

    Brunnett, C.J.

    1980-01-01

    A novel method is described for processing the analogue signals from the photomultiplier tubes in a tomographic X-ray scanner. The system produces a series of pulses whose instantaneous frequency depends on the detected intensity of the X-radiation. A timer unit is used to determine the segment scan intervals and also to deduce the average radiation intensity detected during this interval. The overall system is claimed to possess the advantageous properties of low time delay, wide bandwidth and relative low cost. (U.K.)

  8. Ultra-precision turning of complex spiral optical delay line

    Zhang, Xiaodong; Li, Po; Fang, Fengzhou; Wang, Qichang

    2011-11-01

    Optical delay line (ODL) implements the vertical or depth scanning of optical coherence tomography, which is the most important factor affecting the scanning resolution and speed. The spinning spiral mirror is found as an excellent optical delay device because of the high-speed and high-repetition-rate. However, it is one difficult task to machine the mirror due to the special shape and precision requirement. In this paper, the spiral mirror with titled parabolic generatrix is proposed, and the ultra-precision turning method is studied for its machining using the spiral mathematic model. Another type of ODL with the segmental shape is also introduced and machined to make rotation balance for the mass equalization when scanning. The efficiency improvement is considered in details, including the rough cutting with the 5- axis milling machine, the machining coordinates unification, and the selection of layer direction in turning. The onmachine measuring method based on stylus gauge is designed to analyze the shape deviation. The air bearing is used as the measuring staff and the laser interferometer sensor as the position sensor, whose repeatability accuracy is proved up to 10nm and the stable feature keeps well. With this method developed, the complex mirror with nanometric finish of 10.7nm in Ra and the form error within 1um are achieved.

  9. Ultrafast scanning tunneling microscopy

    Botkin, D.A. [California Univ., Berkeley, CA (United States). Dept. of Physics]|[Lawrence Berkeley Lab., CA (United States)

    1995-09-01

    I have developed an ultrafast scanning tunneling microscope (USTM) based on uniting stroboscopic methods of ultrafast optics and scanned probe microscopy to obtain nanometer spatial resolution and sub-picosecond temporal resolution. USTM increases the achievable time resolution of a STM by more than 6 orders of magnitude; this should enable exploration of mesoscopic and nanometer size systems on time scales corresponding to the period or decay of fundamental excitations. USTM consists of a photoconductive switch with subpicosecond response time in series with the tip of a STM. An optical pulse from a modelocked laser activates the switch to create a gate for the tunneling current, while a second laser pulse on the sample initiates a dynamic process which affects the tunneling current. By sending a large sequence of identical pulse pairs and measuring the average tunnel current as a function of the relative time delay between the pulses in each pair, one can map the time evolution of the surface process. USTM was used to measure the broadband response of the STM`s atomic size tunnel barrier in frequencies from tens to hundreds of GHz. The USTM signal amplitude decays linearly with the tunnel junction conductance, so the spatial resolution of the time-resolved signal is comparable to that of a conventional STM. Geometrical capacitance of the junction does not appear to play an important role in the measurement, but a capacitive effect intimately related to tunneling contributes to the measured signals and may limit the ultimate resolution of the USTM.

  10. Guide device

    Brammer, C.M. Jr.

    1977-01-01

    Disclosed is a fuel handling guide tube centering device for use in nuclear reactors during fuel assembly handling operations. The device comprises an outer ring secured to the flange of a nuclear reactor pressure vessel, a rotatable table rotatably coupled to the outer ring, and a plurality of openings through the table. Truncated locating cones are positioned in each of the openings in the table, and the locating cones center the guide tube during fuel handling operations. The openings in the table are located such that each fuel assembly in the nuclear core may be aligned with one of the openings by a suitable rotation of the table. The locating cones thereby provide alignment between the fuel handling mechanism located in the guide tube and the individual fuel assemblies of the cone. The need for a device to provide alignment is especially critical for floating nuclear power plants, where wave motion may exist during fuel handling operations. 5 claims, 4 figures

  11. Radioactive gaseous waste processing device

    Kawabe, Ken-ichi; Uchiyama, Yoshio; Konno, Masanobu; Suzuki, Kunihiko; Kimura, Tadahiro.

    1991-01-01

    A main steam bypass line is disposed to a main steam line of an air extractor for directly sending diluting steams to an exhaust gas line disposed upstream of a preheater not by way of the extractor. Then, a hydrogen flowmeter is disposed to a hydrogen injection line of a hydrogen supply device for measuring the amount of hydrogen to be injected. Further, a control means is disposed to the main steam bypass line for controlling the injection of the diluting steams based on a signal from the hydrogen flowmeter. With such a constitution, the amount of the hydrogen gas supplied from the hydrogen supply device is detected by the hydrogen flowmeter. The control means disposed to the main steam bypass line or the control means disposed directly to the main steam line injects the diluting steams to the exhaust gas line based on the signal from the hydrogen flowmeter. This can reduce the hydrogen concentration in the exhaust gas upstream of the pre-heater to less than an explosive limit, to enable a countermeasure for preventing hydrogen explosion upon hydrogen injection. (T.M.)

  12. Protection devices in the transmission grids, German practice. Typical protection concepts in Germany's power transmission lines; Schutzsysteme im Uebertragungsnetz, deutsche Praxis. Typische Schutzkonzepte im deutschen Uebertragungsnetz

    Herrmann, Hans-Joachim [Siemens AG, Nuernberg (Germany). Sektor Energy, Energy Automation; Ludwig, Andrea [50 Hertz Transmission GmbH, Berlin (Germany). Schutztechnik, Anlagenmanagement; Kuehn, Holger [Tennet TSO GmbH, Bayreuth (Germany). Schutztechnik, Assetmanagement/Umspannwerke; Oechsle, Fred [EnBW Regional AG, Stuttgart (Germany). Netzschutz, Netzservice - Projekte Strom

    2011-04-18

    The contribution presents typical protection concepts for power grids. Solutions for power plant feed-in, bus bar, transmission lines and coupling transformer are explained. General information is provided on triggering concepts, on the design of d.c. power supply, selection of current inverters, and other subjects.

  13. Investigation into scanning tunnelling luminescence microscopy

    Manson-Smith, S.K.

    2001-01-01

    This work reports on the development of a scanning tunnelling luminescence (STL) microscope and its application to the study of Ill-nitride semiconductor materials used in the production of light emitting devices. STL microscopy is a technique which uses the high resolution topographic imaging capabilities of the scanning tunnelling microscope (STM) to generate high resolution luminescence images. The STM tunnelling current acts as a highly localised source of electrons (or holes) which generates luminescence in certain materials. Light generated at the STM tunnelling junction is collected concurrently with the height variation of the tunnelling probe as it is scanned across a sample surface, producing simultaneous topographic and luminescence images. Due to the very localised excitation source, high resolution luminescence images can be obtained. Spectroscopic resolution can be obtained by using filters. Additionally, the variation of luminescence intensity with tunnel current and with bias voltage can provide information on recombination processes and material properties. The design and construction of a scanning tunnelling luminescence microscope is described in detail. Operating under ambient conditions, the microscope has several novel features, including a new type of miniature inertial slider-based approach motor, large solid-angle light collection optical arrangement and a tip-height regulation system which requires the minimum of operator input. (author)

  14. IMPROVED REAL-TIME SCAN MATCHING USING CORNER FEATURES

    H. A. Mohamed

    2016-06-01

    Full Text Available The automation of unmanned vehicle operation has gained a lot of research attention, in the last few years, because of its numerous applications. The vehicle localization is more challenging in indoor environments where absolute positioning measurements (e.g. GPS are typically unavailable. Laser range finders are among the most widely used sensors that help the unmanned vehicles to localize themselves in indoor environments. Typically, automatic real-time matching of the successive scans is performed either explicitly or implicitly by any localization approach that utilizes laser range finders. Many accustomed approaches such as Iterative Closest Point (ICP, Iterative Matching Range Point (IMRP, Iterative Dual Correspondence (IDC, and Polar Scan Matching (PSM handles the scan matching problem in an iterative fashion which significantly affects the time consumption. Furthermore, the solution convergence is not guaranteed especially in cases of sharp maneuvers or fast movement. This paper proposes an automated real-time scan matching algorithm where the matching process is initialized using the detected corners. This initialization step aims to increase the convergence probability and to limit the number of iterations needed to reach convergence. The corner detection is preceded by line extraction from the laser scans. To evaluate the probability of line availability in indoor environments, various data sets, offered by different research groups, have been tested and the mean numbers of extracted lines per scan for these data sets are ranging from 4.10 to 8.86 lines of more than 7 points. The set of all intersections between extracted lines are detected as corners regardless of the physical intersection of these line segments in the scan. To account for the uncertainties of the detected corners, the covariance of the corners is estimated using the extracted lines variances. The detected corners are used to estimate the transformation parameters

  15. Factors influencing bone scan quality

    Adams, F.G.; Shirley, A.W.

    1983-01-01

    A reliable subjective method of assessing bone scan quality is described. A large number of variables which theoretically could influence scan quality were submitted to regression and factor analysis. Obesity, age, sex and abnormality of scan were found to be significant but weak variables. (orig.)

  16. Medical Devices

    Verkerke, Gijsbertus Jacob; Mahieu, H.F.; Geertsema, A.A.; Hermann, I.F.; van Horn, J.R.; Hummel, J. Marjan; van Loon, J.P.; Mihaylov, D.; van der Plaats, A.; Schraffordt Koops, H.; Schutte, H.K.; Veth, R.P.H.; de Vries, M.P.; Rakhorst, G.; Shi, Donglu

    2004-01-01

    The development of new medical devices is a very time-consuming and costly process. Besides the time between the initial idea and the time that manufacturing and testing of prototypes takes place, the time needed for the development of production facilities, production of test series, marketing,

  17. Electrochemical device

    Grimes, Patrick G.; Einstein, Harry; Bellows, Richard J.

    1988-01-12

    A tunnel protected electrochemical device features channels fluidically communicating between manifold, tunnels and cells. The channels are designed to provide the most efficient use of auxiliary power. The channels have a greater hydraulic pressure drop and electrical resistance than the manifold. This will provide a design with the optimum auxiliary energy requirements.

  18. Assistive Devices

    If you have a disability or injury, you may use a number of assistive devices. These are tools, products or types of equipment that help you perform tasks and activities. They may help you move around, see, communicate, eat, or get ...

  19. Detection device

    Smith, J.E.

    1981-02-27

    The present invention is directed to a detection device comprising: (1) an entrance chamber; (2) a central chamber; and (3) an exit chamber. The central chamber includes an ionizing gas, anode, and means for connecting the anode with an external power supply and pulse counter.

  20. production lines

    Jingshan Li

    2000-01-01

    Full Text Available In this work, serial production lines with finished goods buffers operating in the pull regime are considered. The machines are assumed to obey Bernoulli reliability model. The problem of satisfying customers demand is addressed. The level of demand satisfaction is quantified by the due-time performance (DTP, which is defined as the probability to ship to the customer a required number of parts during a fixed time interval. Within this scenario, the definitions of DTP bottlenecks are introduced and a method for their identification is developed.

  1. CT scans in encephalitis

    Imanishi, Masami; Morimoto, Tetsuya; Iida, Noriyuki; Hisanaga, Manabu; Kinugawa, Kazuhiko

    1980-01-01

    Generally, CT scans reveal a decrease in the volume of the ventricular system, sylvian fissures and cortical sulci in the acute stage of encephalitis, and softening of the cerebral lobes with dilatation of the lateral ventricles and subarachnoidian dilated spaces in the chronic stage. We encountered three cases of encephalitis: mumps (case 1), herpes simplex (case 2), and syphilis (case 3). In case 1, brain edema was seen in the acute stage and brain atrophy in the chronic stage. In case 2, necrosis of the temporal pole, which is pathognomonic in herpes simplex encephalitis, was recognized. And in case 3, multiple lesions whose CT appearance was enhanced by contrast materials were found scattered over the whole brain. These lesions were diagnosed as inflammatory granuloma by histological examination. (author)

  2. Scanning the periphery.

    Day, George S; Schoemaker, Paul J H

    2005-11-01

    Companies often face new rivals, technologies, regulations, and other environmental changes that seem to come out of left field. How can they see these changes sooner and capitalize on them? Such changes often begin as weak signals on what the authors call the periphery, or the blurry zone at the edge of an organization's vision. As with human peripheral vision, these signals are difficult to see and interpret but can be vital to success or survival. Unfortunately, most companies lack a systematic method for determining where on the periphery they should be looking, how to interpret the weak signals they see, and how to allocate limited scanning resources. This article provides such a method-a question-based framework for helping companies scan the periphery more efficiently and effectively. The framework divides questions into three categories: learning from the past (What have been our past blind spots? What instructive analogies do other industries offer? Who in the industry is skilled at picking up weak signals and acting on them?); evaluating the present (What important signals are we rationalizing away? What are our mavericks, outliers, complainers, and defectors telling us? What are our peripheral customers and competitors really thinking?); and envisioning the future (What future surprises could really hurt or help us? What emerging technologies could change the game? Is there an unthinkable scenario that might disrupt our business?). Answering these questions is a good first step toward anticipating problems or opportunities that may appear on the business horizon. The article concludes with a self-test that companies can use to assess their need and capability for peripheral vision.

  3. Cooling device in thermonuclear device

    Honda, Tsutomu.

    1988-01-01

    Purpose: To prevent loss of cooling effect over the entire torus structure directly after accidental toubles in a cooling device of a thermonuclear device. Constitution: Coolant recycling means of a cooling device comprises two systems, which are alternately connected with in-flow pipeways and exit pipeways of adjacent modules. The modules are cooled by way of the in-flow pipeways and the exist pipeways connected to the respective modules by means of the coolant recycling means corresponding to the respective modules. So long as one of the coolant recycling means is kept operative, since every one other modules of the torus structure is still kept cooled, the heat generated from the module put therebetween, for which the coolant recycling is interrupted, is removed by means of heat conduction or radiation from the module for which the cooling is kept continued. No back-up emergency cooling system is required and it can provide high economic reliability. (Kamimura, M.)

  4. Scanning Tunneling Optical Resonance Microscopy

    Bailey, Sheila; Wilt, Dave; Raffaelle, Ryne; Gennett, Tom; Tin, Padetha; Lau, Janice; Castro, Stephanie; Jenkins, Philip; Scheiman, Dave

    2003-01-01

    Scanning tunneling optical resonance microscopy (STORM) is a method, now undergoing development, for measuring optoelectronic properties of materials and devices on the nanoscale by means of a combination of (1) traditional scanning tunneling microscopy (STM) with (2) tunable laser spectroscopy. In STORM, an STM tip probing a semiconductor is illuminated with modulated light at a wavelength in the visible-to-near-infrared range and the resulting photoenhancement of the tunneling current is measured as a function of the illuminating wavelength. The photoenhancement of tunneling current occurs when the laser photon energy is sufficient to excite charge carriers into the conduction band of the semiconductor. Figure 1 schematically depicts a proposed STORM apparatus. The light for illuminating the semiconductor specimen at the STM would be generated by a ring laser that would be tunable across the wavelength range of interest. The laser beam would be chopped by an achromatic liquid-crystal modulator. A polarization-maintaining optical fiber would couple the light to the tip/sample junction of a commercial STM. An STM can be operated in one of two modes: constant height or constant current. A STORM apparatus would be operated in the constant-current mode, in which the height of the tip relative to the specimen would be varied in order to keep the tunneling current constant. In this mode, a feedback control circuit adjusts the voltage applied to a piezoelectric actuator in the STM that adjusts the height of the STM tip to keep the tunneling current constant. The exponential relationship between the tunneling current and tip-to-sample distance makes it relatively easy to implement this mode of operation. The choice of method by which the photoenhanced portion of the tunneling current would be measured depends on choice of the frequency at which the input illumination would be modulated (chopped). If the frequency of modulation were low enough (typically tunneling current

  5. Scanning electron microscopy of semiconductor materials

    Bresse, J.F.; Dupuy, M.

    1978-01-01

    The use of scanning electron microscopy in semiconductors opens up a large field of use. The operating modes lending themselves to the study of semiconductors are the induced current, cathodoluminescence and the use of the potential contrast which can also be applied very effectively to the study of the devices (planar in particular). However, a thorough knowledge of the mechanisms of the penetration of electrons, generation and recombination of generated carriers in a semiconductor is necessary in order to attain a better understanding of the operating modes peculiar to semiconductors [fr

  6. Frequency scanning interferometry for CLIC component fiducialisation

    Kamugasa, Solomon William; Mainaud Durand, Helene; CERN. Geneva. ATS Department

    2016-01-01

    We present a strategy for the fiducialisation of CLIC’s Main Beam Quadrupole (MBQ) magnets using Frequency Scanning Interferometry (FSI). We have developed complementary device for a commercial FSI system to enable coordinate determination via multilateration. Using spherical high index glass retroreflectors with a wide acceptance angle, we optimise the geometry of measurement stations with respect to fiducials -- thus improving the precision of coordinates. We demonstrate through simulations that the 10 μm uncertainty required in the vertical and lateral axes for the fiducialisation of the MBQ can be attained using FSI multilateration.

  7. Spectrum scanning of monochromator by microcontroller ATtiny 2313

    Veklich, A.M.; Boretskij, V.F.; Kleshich, M.M.; Fesenko, S.O.

    2009-01-01

    The results of interface developing on the base of Atmel microcontroller ATtiny 2313 are shown. This device is dedicated to the spectrum scanning of monochromators by the step motor. The design principles of motor control scheme are analyzed. The original algorithm of microcontroller program was suggested and realized. The principal performance availability of the USB interface for the purpose of the device control by the personal computer is considered.

  8. Technique and Calculation Results of Currents and Voltages in the Circuits of the Measuring Element of the Protection Device of the Transmission Line Based on the Control of Transient Processes

    Lachugin, V. F.; Kulikov, A. L.; Platonov, P. S.; Vucolov, V. Yu.

    2017-12-01

    The specifics of generation of the signals of current and voltage in the circuits of a directional element of wave relay protection during short circuit (SC) in overhead power transmission lines are considered. The computing method of transient processes in the protection circuits, including frequency filters, that attenuate the parameters of currents and voltages of the mode taking into account the higher harmonic components and probable deviations of the frequency of transmission line from the rated value is presented. It is revealed that it is advisable to implement the measuring circuits of the directional elements of wave relay protection with the three-section filter attenuating the frequencies from 45 to 55 Hz and the low pass filter with cutoff frequency that does not exceed 1 kHz.

  9. Line facilities outline

    1998-08-01

    This book deals with line facilities. The contents of this book are outline line of wire telecommunication ; development of line, classification of section of line and theory of transmission of line, cable line ; structure of line, line of cable in town, line out of town, domestic cable and other lines, Optical communication ; line of optical cable, transmission method, measurement of optical communication and cable of the sea bottom, Equipment of telecommunication line ; telecommunication line facilities and telecommunication of public works, construction of cable line and maintenance and Regulation of line equipment ; regulation on technique, construction and maintenance.

  10. Atomized scan strategy for high definition for VR application

    Huang, Shuping; Ran, Feng; Ji, Yuan; Chen, Wendong

    2017-10-01

    Silicon-based OLED (Organic Light Emitting Display) microdisplay technology begins to attract people's attention in the emerging VR and AR devices. The high display frame refresh rate is an important solution to alleviate the dizziness in VR applications. Traditional display circuit drivers use the analog method or the digital PWM method that follow the serial scan order from the first pixel to the last pixel by using the shift registers. This paper proposes a novel atomized scan strategy based on the digital fractal scan strategy using the pseudo-random scan order. It can be used to realize the high frame refresh rate with the moderate pixel clock frequency in the high definition OLED microdisplay. The linearity of the gray level is also improved compared with the Z fractal scan strategy.

  11. Apparatus and Method for Communication over Power Lines

    Krasowski, Michael J. (Inventor); Prokop, Norman F. (Inventor); Greer, III, Lawrence C. (Inventor); Nappier, Jennifer M. (Inventor)

    2017-01-01

    An apparatus and method are provided for communicating over power lines. The apparatus includes a coupling modem that is situated between a power line and a device. The coupling modem is configured to demodulate a signal received from the power line into a sine signal and a cosine signal. The coupling modem is also configured to modulate a communicated bit stream received from the device into a transmitted signal in order to impose the transmitted signal onto the power line.

  12. CT-scanning in otolaryngology, 2

    Kusakari, Jun; Endo, Satomi; Hara, Akira

    1982-01-01

    Combined computerized tomography-sialography was performed in 28 patients with parotid tumors. Sialography was performed in the usual fashion. After confirming the presence of the contrast material within the parotid gland by X-ray, 4 to 5 scannings were done at the width of 10 mm below Repid's base line. With this procedure, the parotid gland was clearly demonstrated and the location of the tumor was shown as a shadow defect. Although the nature of the tumor, especially whether it was malignant or benign was difficult to predict, the CT-findings regarding the size and location of the tumor were completely coincident with the operative findings in all the cases. Accurate appraisal of the relation between the tumor and the facial nerve was possible in all but two cases. The preoperative information obtained from CT-scanning is extremely useful in the case of parotid tumor surgery. (author)

  13. Superconducting delay lines and chirp filters

    Hoefer, G.J.; Kratz, H.A.

    1993-01-01

    High temperature superconductor (HTSC) thin films are now good enough to realize certain devices, particularly passive analog broadband devices requiring only a single layer of high quality material. This is especially true for long delay lines and related structures, e. g. chirp filters, where low loss and dispersion result in large usable bandwidths. The availability of these devices may hasten the commercialization of the high temperature superconductors, because they take full advantage of their unique properties. (orig.)

  14. Thermonuclear device

    Tezuka, Masaru.

    1993-01-01

    Protrusions and recesses are formed to a vacuum vessel and toroidal magnetic coils, and they are engaged. Since the vacuum vessel is generally supported firmly by a rack or the like by support legs, the toroidal magnetic field coils can be certainly supported against tumbling force. Then, there can be attained strong supports for the toroidal magnetic field coils, in addition to support by wedges on the side of inboard and support by share panels on the side of outboard, capable of withstanding great electromagnetic forces which may occur in large-scaled next-generation devices. That is, toroidal magnetic field coils excellent from a view point of deformation and stress can be obtained, to provide a thermonuclear device of higher reliability. (N.H.)

  15. Thermonuclear device

    Oosaki, Osamu; Masuda, Kenju.

    1980-01-01

    Purpose: To provide excellent electric properties and high reliability in a thermonuclear device by improving a current collecting board connected to a coil device. Constitution: A current collecting board element perforated with an opening for enserting a connecting terminal is sized to be inserted into a plating tank, and is surface treated in the plating tank. Only the current collecting board element preferably surface treated is picked up. A plurality of such current collecting board elements are connected and welded to form a large current collecting board. In this manner, the current collecting board having several m 2 to several ten order m 2 in area can be obtained as preferably surface treated at the connecting terminal hole. The current collecting board element can be determined in shape with the existing facility without increasing the size of a surface treating tank. (Kamimura, M.)

  16. Thermonuclear device

    Yagi, Yasuomi; Takahashi, Ken; Hashimoto, Hiroshi.

    1984-01-01

    Purpose: To improve the plasma confining performances by bringing the irregular magnetic fields nearly to zero and decreasing the absolute value of the irregular magnetic fields at every positions. Constitution: The winding direction of a plurality of coil elements, for instance, double pan cake coils of toroidal coils in a torus type or mirror type thermonuclear device are reversed to each other in their laminating direction, whereby the irregular magnetic fields due to the coil-stepped portions in each toroidal coils are brought nearly to zero. This enables to bring the average irregular magnetic fields as a whole in the thermonuclear device nearly to zero, as well as, decrease the absolute value of the irregular magnetic fields in each positions. Thus, the plasma confining performances can be improved. (Moriyama, K.)

  17. Parallel Lines

    James G. Worner

    2017-05-01

    Full Text Available James Worner is an Australian-based writer and scholar currently pursuing a PhD at the University of Technology Sydney. His research seeks to expose masculinities lost in the shadow of Australia’s Anzac hegemony while exploring new opportunities for contemporary historiography. He is the recipient of the Doctoral Scholarship in Historical Consciousness at the university’s Australian Centre of Public History and will be hosted by the University of Bologna during 2017 on a doctoral research writing scholarship.   ‘Parallel Lines’ is one of a collection of stories, The Shapes of Us, exploring liminal spaces of modern life: class, gender, sexuality, race, religion and education. It looks at lives, like lines, that do not meet but which travel in proximity, simultaneously attracted and repelled. James’ short stories have been published in various journals and anthologies.

  18. "Distinvar" device

    CERN PhotoLab

    1965-01-01

    The alignment of one of the accelerator magnets being checked by the AR Division survey group. A "distinvar" device, invented by the group, using calibrated invar wires stretched between the fixed survey pillar (on the left) and a fixed point on the magnet. In two days it is thus possible to measure the alignment of the 100 magnets with an accuracy better than 1/10.

  19. Latching device

    Ulrich, G. W. (Inventor)

    1975-01-01

    A latching device is suited for use in establishing a substantially motionless connection between a stationary receiver and a movable latching mechanism. The latching mechanism includes a pivotally supported restraining hook continuously urged into a capturing relationship with the receiver, characterized by a spring-biased pawl having a plurality of aligned teeth. The teeth are seated in the surface of the throat of the hook and positionable into restraining engagement with a rigid restraining shoulder projected from the receiver.

  20. CRionScan: A stand-alone real time controller designed to perform ion beam imaging, dose controlled irradiation and proton beam writing

    Daudin, L.; Barberet, Ph.; Serani, L.; Moretto, Ph.

    2013-07-01

    High resolution ion microbeams, usually used to perform elemental mapping, low dose targeted irradiation or ion beam lithography needs a very flexible beam control system. For this purpose, we have developed a dedicated system (called “CRionScan”), on the AIFIRA facility (Applications Interdisciplinaires des Faisceaux d'Ions en Région Aquitaine). It consists of a stand-alone real-time scanning and imaging instrument based on a Compact Reconfigurable Input/Output (Compact RIO) device from National Instruments™. It is based on a real-time controller, a Field Programmable Gate Array (FPGA), input/output modules and Ethernet connectivity. We have implemented a fast and deterministic beam scanning system interfaced with our commercial data acquisition system without any hardware development. CRionScan is built under LabVIEW™ and has been used on AIFIRA's nanobeam line since 2009 (Barberet et al., 2009, 2011) [1,2]. A Graphical User Interface (GUI) embedded in the Compact RIO as a web page is used to control the scanning parameters. In addition, a fast electrostatic beam blanking trigger has been included in the FPGA and high speed counters (15 MHz) have been implemented to perform dose controlled irradiation and on-line images on the GUI. Analog to Digital converters are used for the beam current measurement and in the near future for secondary electrons imaging. Other functionalities have been integrated in this controller like LED lighting using Pulse Width Modulation and a “NIM Wilkinson ADC” data acquisition.

  1. CRionScan: A stand-alone real time controller designed to perform ion beam imaging, dose controlled irradiation and proton beam writing

    Daudin, L., E-mail: daudin@cenbg.in2p3.fr [Université Bordeaux, CENBG, UMR 5797, F-33170 Gradignan (France); CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan (France); Barberet, Ph.; Serani, L.; Moretto, Ph. [Université Bordeaux, CENBG, UMR 5797, F-33170 Gradignan (France); CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan (France)

    2013-07-01

    High resolution ion microbeams, usually used to perform elemental mapping, low dose targeted irradiation or ion beam lithography needs a very flexible beam control system. For this purpose, we have developed a dedicated system (called “CRionScan”), on the AIFIRA facility (Applications Interdisciplinaires des Faisceaux d’Ions en Région Aquitaine). It consists of a stand-alone real-time scanning and imaging instrument based on a Compact Reconfigurable Input/Output (Compact RIO) device from National Instruments™. It is based on a real-time controller, a Field Programmable Gate Array (FPGA), input/output modules and Ethernet connectivity. We have implemented a fast and deterministic beam scanning system interfaced with our commercial data acquisition system without any hardware development. CRionScan is built under LabVIEW™ and has been used on AIFIRA’s nanobeam line since 2009 (Barberet et al., 2009, 2011) [1,2]. A Graphical User Interface (GUI) embedded in the Compact RIO as a web page is used to control the scanning parameters. In addition, a fast electrostatic beam blanking trigger has been included in the FPGA and high speed counters (15 MHz) have been implemented to perform dose controlled irradiation and on-line images on the GUI. Analog to Digital converters are used for the beam current measurement and in the near future for secondary electrons imaging. Other functionalities have been integrated in this controller like LED lighting using Pulse Width Modulation and a “NIM Wilkinson ADC” data acquisition.

  2. Organic material reducing device in nuclear power plant

    Minakata, Noriyuki; Takada, Takao

    1998-01-01

    A total organic carbon (TOC) removing device is disposed between a filtration device and a desalting device or between a condensator and the desalting device disposed to a radioactive liquid waste processing facility or a condensate cleaning system of a BWR type nuclear reactor. Since the removing ratio of the TOC removing device is generally high if impurities are not contained, and ionic ingredients are formed after decomposition, TOC can be decomposed and removed more efficiently and removal in a short period of time can be expected by disposing the TOC device downstream of the filtration device or a condensator to be disposed instead of the filtration device and upstream of the desalting device. Then, further enhanced effect can be expected, if two series of the TOC removing line and the bypass line are disposed between the filtration device or the condensator and the desalting device so as to enable selection of processed liquids. (T.M.)

  3. First results from the INTEGRAL galactic plane scans

    Winkler, C.; Gehrels, N.; Schonfelder, V.

    2003-01-01

    Scans of the Galactic plane performed at regular intervals constitute a key element of the guaranteed time observations of the INTEGRAL observing programme. These scans are done for two reasons: frequent monitoring of the Galactic plane in order to detect transient sources, and time resolved mapp...... mapping of the Galactic plane in continuum and diffuse line emission. This paper describes first results obtained from the Galactic plane scans executed so far during the early phase (Dec. 2002-May 2003) of the nominal mission.......Scans of the Galactic plane performed at regular intervals constitute a key element of the guaranteed time observations of the INTEGRAL observing programme. These scans are done for two reasons: frequent monitoring of the Galactic plane in order to detect transient sources, and time resolved...

  4. GPR scan assessment

    Abbas M. Abbas

    2015-06-01

    Full Text Available Mekaad Radwan monument is situated in the neighborhood of Bab Zuweila in the historical Cairo, Egypt. It was constructed at the middle XVII century (1635 AD. The building has a rectangle shape plan (13 × 6 m with the longitudinal sides approximately WNW-ESE. It comprises three storages namely; the ground floor; the opened floor (RADWAN Bench and the living floor with a total elevation of 15 m above the street level. The building suffers from severe deterioration phenomena with patterns of damage which have occurred over time. These deterioration and damages could be attributed to foundation problems, subsoil water and also to the earthquake that affected the entire Greater Cairo area in October 1992. Ground Penetrating Radar (GPR scan was accomplished against the walls of the opened floor (RADWAN Bench to evaluate the hazard impact on the walls textures and integrity. The results showed an anomalous feature through the southern wall of RADWAN Bench. A mathematical model has been simulated to confirm the obtained anomaly and the model response exhibited a good matching with the outlined anomaly.

  5. Radionuclide brain scanning

    Abdel-Dayem, H.

    1992-01-01

    At one stage of medical imaging development, radionuclide brain scanning was the only technique available for imaging of the brain. Advent of CT and MRI pushed it to the background. It regained some of the grounds lost to ''allied advances'' with the introduction of brain perfusion radiopharmaceuticals. Positron emission tomography is a promising functional imaging modality that at present will remain as a research tool in special centres in developed countries. However, clinically useful developments will gradually percolate from PET to SPECT. The non-nuclear imaging methods are totally instrument dependent; they are somewhat like escalators, which can go that far and no further. Nuclear imaging has an unlimited scope for advance because of the new developments in radiopharmaceuticals. As the introduction of a radiopharmaceutical is less costly than buying new instruments, the recent advances in nuclear imaging are gradually perfusing through the developing countries also. Therefore, it is essential to follow very closely PET developments because what is research today might become routine tomorrow

  6. LANL Robotic Vessel Scanning

    Webber, Nels W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-11-25

    Los Alamos National Laboratory in J-1 DARHT Operations Group uses 6ft spherical vessels to contain hazardous materials produced in a hydrodynamic experiment. These contaminated vessels must be analyzed by means of a worker entering the vessel to locate, measure, and document every penetration mark on the vessel. If the worker can be replaced by a highly automated robotic system with a high precision scanner, it will eliminate the risks to the worker and provide management with an accurate 3D model of the vessel presenting the existing damage with the flexibility to manipulate the model for better and more in-depth assessment.The project was successful in meeting the primary goal of installing an automated system which scanned a 6ft vessel with an elapsed time of 45 minutes. This robotic system reduces the total time for the original scope of work by 75 minutes and results in excellent data accumulation and transmission to the 3D model imaging program.

  7. Gastrointestinal scanning agent

    Francis, M.D.

    1980-01-01

    An easily prepared radiolabeled gastrointestinal scanning agent is described. Technetium-99m has ideal characteristics for imaging the upper and lower GI tract and determining stomach emptying and intestinal transit time when used with an insoluble particulate material. For example, crystalline and amorphous calcium phosphate particles can be effectively labeled in a one-step process using sup(99m)TcO 4 and SnCl 2 . These labeled particles have insignificant mass and when administered orally pass through the GI tract unchanged, without affecting the handling and density of the intestinal contents. Visualization of the esophageal entry into the stomach, the greater and lesser curvatures of the stomach, ejection into the duodenum, and rates of passage through the upper and lower GI tract are obtained. The slurry of sup(99m)TC particulate can be given rectally by enema. Good images of the cecum and the ascending, transverse, and descending colon are obtained. Mucosal folds and the splenic and hepatic flexures are visualized. The resilience of the large intestine is also readily visualized by pneumocolonographic techniques. (author)

  8. Radionuclide brain scanning

    Abdel-Dayem, H

    1993-12-31

    At one stage of medical imaging development, radionuclide brain scanning was the only technique available for imaging of the brain. Advent of CT and MRI pushed it to the background. It regained some of the grounds lost to ``allied advances`` with the introduction of brain perfusion radiopharmaceuticals. Positron emission tomography is a promising functional imaging modality that at present will remain as a research tool in special centres in developed countries. However, clinically useful developments will gradually percolate from PET to SPECT. The non-nuclear imaging methods are totally instrument dependent; they are somewhat like escalators, which can go that far and no further. Nuclear imaging has an unlimited scope for advance because of the new developments in radiopharmaceuticals. As the introduction of a radiopharmaceutical is less costly than buying new instruments, the recent advances in nuclear imaging are gradually perfusing through the developing countries also. Therefore, it is essential to follow very closely PET developments because what is research today might become routine tomorrow

  9. Magnetically scanned proton therapy beams: rationales and techniques

    Jones, D.T.L.; Schreuder, A.N.

    2000-01-01

    Perhaps the most important advantages of beam scanning systems for proton therapy in comparison with conventional passive beam spreading systems are: (1) Intensity modulation and inverse planning are possible. (2) There is negligible reduction in the range of the beam. (3) Integral dose is reduced as dose conformation to the proximal edge of the lesion is possible. (4) In principle no field-specific modifying devices are required. (5) There is less activation of the surroundings. (6) Scanning systems axe almost infinitely flexible. The main disadvantages include: (1) Scanning systems are more complicated and therefore potentially less reliable and more dangerous. (2) The development of such systems is more demanding in terms of cost, time and manpower. (3) More stable beams are required. (4) Dose and beam position monitoring are more difficult. (5) The problems associated with patient and organ movement axe more severe. There are several techniques which can be used for scanning. For lateral beam spreading, circular scanning (wobbling) or linear scanning can be done. In the latter case the beam can be scanned continuously or in a discrete fashion (spot scanning). Another possibility is to undertake the fastest scan in one dimension (strip scanning) and translate the patient or the scanning magnet in the other dimension. Depth variation is achieved by interposing degraders in the beam (cyclotrons) or by changing the beam energy (synchrotrons). The aim of beam scanning is to deliver a predetermined dose at any point in the body. Special safety precautions must be taken because of the high instantaneous dose rates. The beam position and the dose delivered at each point must be accurately and redundantly determined. (author)

  10. Analysis of Corneal Astigmatism with NIDEK Axial Length Scan in ...

    2018-04-04

    Apr 4, 2018 ... AL‑scan optical biometric device in healthy cataract patients. Patients and Methods. In this retrospective study, patient datasets were acquired between March 1, 2014 and April 15, 2016, at the. Department of Ophthalmology, Afyon Kocatepe University. The Bursa Yüksek Ihtisas Hospital's Ethics Committee.

  11. Hyperchromatic laser scanning cytometry

    Tárnok, Attila; Mittag, Anja

    2007-02-01

    In the emerging fields of high-content and high-throughput single cell analysis for Systems Biology and Cytomics multi- and polychromatic analysis of biological specimens has become increasingly important. Combining different technologies and staining methods polychromatic analysis (i.e. using 8 or more fluorescent colors at a time) can be pushed forward to measure anything stainable in a cell, an approach termed hyperchromatic cytometry. For cytometric cell analysis microscope based Slide Based Cytometry (SBC) technologies are ideal as, unlike flow cytometry, they are non-consumptive, i.e. the analyzed sample is fixed on the slide. Based on the feature of relocation identical cells can be subsequently reanalyzed. In this manner data on the single cell level after manipulation steps can be collected. In this overview various components for hyperchromatic cytometry are demonstrated for a SBC instrument, the Laser Scanning Cytometer (Compucyte Corp., Cambridge, MA): 1) polychromatic cytometry, 2) iterative restaining (using the same fluorochrome for restaining and subsequent reanalysis), 3) differential photobleaching (differentiating fluorochromes by their different photostability), 4) photoactivation (activating fluorescent nanoparticles or photocaged dyes), and 5) photodestruction (destruction of FRET dyes). With the intelligent combination of several of these techniques hyperchromatic cytometry allows to quantify and analyze virtually all components of relevance on the identical cell. The combination of high-throughput and high-content SBC analysis with high-resolution confocal imaging allows clear verification of phenotypically distinct subpopulations of cells with structural information. The information gained per specimen is only limited by the number of available antibodies and by sterical hindrance.

  12. Mesooptical Fourier transform microscope - a new device for high energy physics

    Astakhov, A.Ya.; Batusov, Yu.A.; Bencze, Gy.L.; Farago, I.; Kisvaradi, A.; Molnar, L.; Soroko, L.M.; Vegh, J.

    1988-01-01

    A new device for high energy physics, Mesooptical Fourier Transform Microscope (MFTM), designed for observation of straight-line particle tracks in nuclear emulsion is described. The MFTM works without any mechanical or electronical depth scanning and can be considered as a selectively viewing eye. The computer controlled system containing MFTM as the main unit is given. This system can be used for fast search particle tracks and events produced by high energy neutrinos from accelerators. The results of the first experimental test of the computer controlled MFTM are presented. The performances of this system are described and discussed. It is shown that the angular resolution of the MFTM is 1 angular minute and the measurement time is equal to 30 ms. As all operations in the MFTM go without any depth scanning this new system works at least two orders of magnitude faster than any known system with a traditional optical microscope

  13. Meso-optical Fourier transform microscope - a new device for high energy physics

    Astakhov, A.Ya.; Batusov, Yu.A.; Bencze, G.L.; Farago, I.; Kisvaradi, A.; Molnar, L.; Soroko, L.M.; Vegh, J.

    1989-01-01

    A new device for high energy physics, the Meso-optical Fourier Transform Microscope (MFTM), designed for observation fo straight line particle tracks in nuclear research emulsion is described. The MFTM works without any mechanical or electronical depth scanning and can be considered as a selectivity viewing 'eye'. The computer controlled system containing MFTM as its main unit is given. This system can be used for a fast search for particle tracks and events produced by high energy neutrinos from particle accelerators. The results of the first experimental test of the computer controlled MFTM are presented. The performance of this system is described and discussed. It is shown that the angular resolution of the MFTM is 1 angular minute and the measurement time is equal to 30 ms per image. As all operations in the MFTM proceed without any depth scanning, this new evaluation system works at least two orders of magnitude faster than any known system with a traditional optical microscope. (orig.)

  14. Damping device

    Banks, E.L. Jr.; Dowell, T.P.

    1976-01-01

    The description is given of a damper which includes a pair of telescopic components interconnected by relative linear movement one in relation to the other, by a screw and ball nut device, with a braking surface on one of the components, a brake engaging the braking surface, an inertia mass entrained by the other components, non-deformable and distinct brake actuating gear, independently mobile in relation to the other braking system and fixed and controlled by the inertia mass, positively to engage the braking surface. This damper is for retaining the parts of a nuclear power station so that can withstand earthquakes [fr

  15. Thermonuclear device

    Inoue, Toyokazu; Murata, Toru.

    1983-01-01

    Purpose: To shield superconducting coils for use in the generation of magnetic field against neutron irradiation thereby preventing tritium contamination. Constitution: The thermonuclear device comprises, in its inside, a vacuum container for containing plasmas, superconducting coils disposed to the outside of the vacuum container and neutron absorbers disposed between the super-conducting coils and the vacuum container. since neutrons issued from the plasma are absorbed by neutron absorbers and not irradiated to the superconducting coils, generation of tritium due to the reaction between 3 He in the liquid helium as the coolants for the super-conducting coils and the neutrons is prevented. (Aizawa, K.)

  16. On line portal imaging

    Munro, Peter

    1996-01-01

    Purpose/Objective: The purpose of this presentation is to examine the various imaging devices that have been developed for portal imaging; describe some of the image registration methods that have been developed to determine geometric errors quantitatively; discuss some of the ways that portal imaging has been incorporated into routine clinical practice; describe quality assurance procedures for these devices, and discuss the use of portal imaging devices for dosimetry applications. Discussion: Verification of patient positioning has always been an important aspect of external beam radiation therapy. Over the past decade many portal imaging devices have been developed by individual investigators and most accelerator manufacturers now offer 'on-line' portal imaging systems. The commercial devices can be classified into three categories: T.V. camera-based systems, liquid ionisation chamber systems, and amorphous silicon systems. Many factors influence the quality of images generated by these portal imaging systems. These include factors which are unavoidable (e.g., low subject contrast), factors which depend upon the individual imaging device forming the image (e.g., dose utilisation, spatial resolution) as well as factors which depend upon the characteristics of the linear accelerator irradiating the imaging system (x-ray source size, image magnification). The characteristics of individual imaging systems, such as spatial resolution, temporal response, and quantum utilisation will be discussed. One of the major advantages of on-line portal imaging is that many quantitative techniques have been developed to detect errors in patient positioning. The general approach is to register anatomic structures on a portal image with the same structures on a digitized simulator film. Once the anatomic structures have been registered, any discrepancies in the position of the patient can be identified. However, the task is not nearly as straight-forward as it sounds. One problem

  17. Development of scanning micromirror with discrete steering angles

    Wang, Z F; Noell, W; Zickar, M; Rooij, N F de; Lim, S P

    2006-01-01

    This paper describes the development of a new MEMS-based optical mirror, which can perform optical switching (or scanning) function with discrete reflection angles in an outof- plane configuration. The device is fabricated through the Deep Reactive Ion Etching (DRIE) process on silicon-on-insulator (SOI) wafer, followed by wafer dicing and assembly with two metalised glass dies. The MEMS mirror can be tilted under electrostatic force between the opposite electrodes embedded on SOI and glass structures. The most outstanding feature of this MEMS mirror is the discrete and therefore, reliable tilting angles, which generated by its unique mechanical structural design and electrostatic-driven mechanism. In this paper, the concept of the new scanning mirror is presented, followed by the introduction of device design, mechanical simulation, microfabrication process, assembly solution, and some testing results. The potential applications of this new MEMS mirror include optical scanning, optical sensing (or detection), and optical switching

  18. Gallium scans in myasthenia gravis

    Swick, H.M.; Preston, D.F.; McQuillen, M.P.

    1976-01-01

    A study was conducted to determine whether 67 Ga scans could be used for the detection of thymomas and to investigate the activity of the thymus gland in patients with myasthenia gravis. Scans of the anterior mediastinum proved to be a reliable way to detect thymomas. The scans were positive in eight patients including three with myasthenia gravis and histologically proved thymomas, three others with severe myasthenia gravis and thymic tumors, and two with histologically proved thymomas not associated with myasthenia. Activity on 67 Ga scans was not directly related to the increased activity of the thymus gland that is presumed to be associated with myasthenia gravis

  19. Gallium scans in myasthenia gravis

    Swick, H.M. (Univ. of Kentucky, Lexington); Preston, D.F.; McQuillen, M.P.

    1976-01-01

    A study was conducted to determine whether /sup 67/Ga scans could be used for the detection of thymomas and to investigate the activity of the thymus gland in patients with myasthenia gravis. Scans of the anterior mediastinum proved to be a reliable way to detect thymomas. The scans were positive in eight patients including three with myasthenia gravis and histologically proved thymomas, three others with severe myasthenia gravis and thymic tumors, and two with histologically proved thymomas not associated with myasthenia. Activity on /sup 67/Ga scans was not directly related to the increased activity of the thymus gland that is presumed to be associated with myasthenia gravis. (HLW)

  20. Device for extracting steam or gas from the primary coolant line leading from a reactor pressure vessel to a straight through boiler or from the top primary boiler chamber of a water-cooled nuclear reactor

    Schatz, K.

    1982-01-01

    In such a nuclear reactor, a steam or gas cushion can form when the primary system is refilled, which can cause blocking of the natural circulation or filling of the system in the area of the hot primary coolant pipe or in the top primary boiler chamber. In order to remove such a steam or gas cushion, a ventilation pipe starting from the bend of the primary coolant line is connected to the feed pipe for introducing water into the primary system. The feed pipe is designed on the principle of the vacuum pump in the area of the opening of the ventilation pipe. There is a sub-pressure in the ventilation pipe, which makes it possible to extract the steam or gas. After mixing in the area of the opening, the steam condenses or is distributed with the gas in the primary coolant. (orig.) [de

  1. Large Scale Scanning Probe Microscope "Making Shear Force Scanning visible."

    Bosma, E.; Offerhaus, Herman L.; van der Veen, Jan T.; van der Veen, J.T.; Segerink, Franciscus B.; Wessel, I.M.

    2010-01-01

    We describe a demonstration of a scanning probe microscope with shear-force tuning fork feedback. The tuning fork is several centimeters long, and the rigid fiber is replaced by a toothpick. By scaling this demonstration to visible dimensions the accessibility of shear-force scanning and tuning fork

  2. VT Digital Line Graph Miscellaneous Transmission Lines

    Vermont Center for Geographic Information — (Link to Metadata) This datalayer is comprised of Miscellaineous Transmission Lines. Digital line graph (DLG) data are digital representations of cartographic...

  3. Laser safety in design of near-infrared scanning LIDARs

    Zhu, X.; Elgin, D.

    2015-05-01

    3D LIDARs (Light Detection and Ranging) with 1.5μm nanosecond pulse lasers have been increasingly used in different applications. The main reason for their popularity is that these LIDARs have high performance while at the same time can be made eye-safe. Because the laser hazard effect on eyes or skin at this wavelength region (industrial mining applications. We have incorporated the laser safety requirements in the LIDAR design and conducted laser safety analysis for different operational scenarios. While 1.5μm is normally said to be the eye-safe wavelength, in reality a high performance 3D LIDAR needs high pulse energy, small beam size and high pulse repetition frequency (PRF) to achieve long range, high resolution and high density images. The resulting radiant exposure of its stationary beam could be many times higher than the limit for a Class 1 laser device. Without carefully choosing laser and scanning parameters, including field-of-view, scan speed and pattern, a scanning LIDAR can't be eye- or skin-safe based only on its wavelength. This paper discusses the laser safety considerations in the design of eye-safe scanning LIDARs, including laser pulse energy, PRF, beam size and scanning parameters in two basic designs of scanning mechanisms, i.e. galvanometer based scanner and Risley prism based scanner. The laser safety is discussed in terms of device classification, nominal ocular hazard distance (NOHD) and safety glasses optical density (OD).

  4. Scanning tunneling microscopy II further applications and related scanning techniques

    Güntherodt, Hans-Joachim

    1995-01-01

    Scanning Tunneling Microscopy II, like its predecessor, presents detailed and comprehensive accounts of the basic principles and broad range of applications of STM and related scanning probe techniques. The applications discussed in this volume come predominantly from the fields of electrochemistry and biology. In contrast to those described in STM I, these studies may be performed in air and in liquids. The extensions of the basic technique to map other interactions are described in chapters on scanning force microscopy, magnetic force microscopy, and scanning near-field optical microscopy, together with a survey of other related techniques. Also described here is the use of a scanning proximal probe for surface modification. Together, the two volumes give a comprehensive account of experimental aspects of STM. They provide essential reading and reference material for all students and researchers involved in this field. In this second edition the text has been updated and new methods are discussed.

  5. Scanning tunneling microscopy II further applications and related scanning techniques

    Güntherodt, Hans-Joachim

    1992-01-01

    Scanning Tunneling Microscopy II, like its predecessor, presents detailed and comprehensive accounts of the basic principles and broad range of applications of STM and related scanning probe techniques. The applications discussed in this volume come predominantly from the fields of electrochemistry and biology. In contrast to those described in Vol. I, these sudies may be performed in air and in liquids. The extensions of the basic technique to map other interactions are described inchapters on scanning force microscopy, magnetic force microscopy, scanning near-field optical microscopy, together with a survey of other related techniques. Also described here is the use of a scanning proximal probe for surface modification. Togehter, the two volumes give a comprehensive account of experimental aspcets of STM. They provide essentialreading and reference material for all students and researchers involvedin this field.

  6. Scalable devices

    Krüger, Jens J.

    2014-01-01

    In computer science in general and in particular the field of high performance computing and supercomputing the term scalable plays an important role. It indicates that a piece of hardware, a concept, an algorithm, or an entire system scales with the size of the problem, i.e., it can not only be used in a very specific setting but it\\'s applicable for a wide range of problems. From small scenarios to possibly very large settings. In this spirit, there exist a number of fixed areas of research on scalability. There are works on scalable algorithms, scalable architectures but what are scalable devices? In the context of this chapter, we are interested in a whole range of display devices, ranging from small scale hardware such as tablet computers, pads, smart-phones etc. up to large tiled display walls. What interests us mostly is not so much the hardware setup but mostly the visualization algorithms behind these display systems that scale from your average smart phone up to the largest gigapixel display walls.

  7. Thermonuclear device

    Honda, Takuro; Maki, Koichi.

    1997-01-01

    The present invention provides a thermonuclear device, in which integrity of a measuring device is kept, the reactor wall temperature and wear of armour materials are monitored accurately even under intense radiation rays, so that the flow rate of coolants and plasma power can be controlled by using the signals. Infrared rays generated from the surface of the armour materials disposed on a first wall are detected to measure the reactor wall temperature. Coolant flow rate and plasma power are controlled based on the obtained reactor wall temperature. In addition, infrared rays generated from the back of the armour materials are detected to obtain the surface temperature in order to avoid intense radiation rays from plasmas. The coolant flow rate and the plasma power are controlled based on the obtained temperature on the surface of the reactor thereby controlling the temperature of the first wall and the armour material to 300degC or lower in a case of the first wall made of stainless steel and 1000degC or lower in a case of the armour material made of graphite. (I.S.)

  8. Thermonuclear device

    Kuriyama, Masaaki; Yamamoto, Masahiro; Furuyama, Masayuki; Saito, Ryusei.

    1981-01-01

    Purpose: To enable the efficient and rapid cooling of a vacuum vessel by cooling with gas when the temperature of the vacuum vessel is higher than the boiling point of water and cooling with water when the temperature is lower than the boiling point of water. Constitution: A cooling pipe is provided through an insulating pipe on the outer periphery of a vacuum vessel. The cooling pipe communicates through a cooling gas valve and a coolant valve with a cooling gas supply device and a coolant supply device, and a heat exchanger is disposed at the pipe. When the vessel is higher than the boiling point of the coolant the coolant valve is closed and the cooling gas valve is opened and gas is supplied to cool the vessel. The gas is recoverd through a heat exchanger. On the other hand, when the temperature of vessel is lower than the boiling point of the coolant, the gas valve is closed, the coolant valve is opened, and the vessel is cooled with coolant. The vacuum vessel can be cooled for short time employing both the gas and the coolant together. (Yoshino, Y.)

  9. Thermonuclear device

    Takano, Hirohisa; Nakamoto, Kazunari; Hanai, Satoshi.

    1984-01-01

    Purpose: To provide coils of high mechanical strength for use at the center of a torus type thermonuclear device. Constitution: A plurality of copper plates having cooling holes and bolt holes and insulation paper sheets of the same shape are prepared. The copper plate is different from the insulation paper sheet only in that the position-phase angle of the opening portion is larger by 15 - 30 0 . The copper plates and the insulation paper sheets are alternately stacked by a required number of turns while displacing the angle, and then clamped by bolts to form a mechanically strong coil with no metallurgical joining. Further, since the insulation paper sheets are not present in the radial direction and only one insulation paper sheet is inserted for each turn in the direction of the coil height, the space occupied by the coil can be decreased. According to this invention, the magnetic flux density at the center of the device can be increased as compared with the conventional case to thereby apply a higher voltage on the side of plasmas. (Moriyama, K.)

  10. Rf superconducting devices

    Hartwig, W.H.; Passow, C.

    1975-01-01

    Topics discussed include (1) the theory of superconductors in high-frequency fields (London surface impedance, anomalous normal surface resistance, pippard nonlocal theory, quantum mechanical model, superconductor parameters, quantum mechanical calculation techniques for the surface, impedance, and experimental verification of surface impedance theories); (2) residual resistance (separation of losses, magnetic field effects, surface resistance of imperfect and impure conductors, residual loss due to acoustic coupling, losses from nonideal surfaces, high magnetic field losses, field emission, and nonlinear effects); (3) design and performance of superconducting devices (design considerations, materials and fabrication techniques, measurement of performance, and frequency stability); (4) devices for particle acceleration and deflection (advantages and problems of using superconductors, accelerators for fast particles, accelerators for particles with slow velocities, beam optical devices separators, and applications and projects under way); (5) applications of low-power superconducting resonators (superconducting filters and tuners, oscillators and detectors, mixers and amplifiers, antennas and output tanks, superconducting resonators for materials research, and radiation detection with loaded superconducting resonators); and (6) transmission and delay lines

  11. Scanning tunneling spectroscopy on superconducting proximity nanostructures

    Chapelier, C; Vinet, M; Lefloch, F

    2001-01-01

    We investigated the local density of states (LDOS) of a normal metal (N) in good electrical contact with a superconductor (S) as a function of the distance x to the NS interface. The sample consists of a pattern of alternate L = 1 mm wide strips of Au and Nb made by UV lithography. We used a low temperature scanning tunneling microscope and a lock-in detection technique to record simultaneously dI/dV(V,x) curves and the topographic profile z(x) at 1.5 K. We scanned along lines perpendicular to the strips. All the spectra show a dip near the Fermi energy, which spectral extension decreases from the superconducting gap Δ at the NS interface to zero at distances x >> ξ N where ξ N ≅ √hD N /2Δ ≅ 53nm is the coherence length in the normal metal. Our measurements are correctly described in the framework of the quasi-classical Green's function formalism. We numerically solved the 1D Usadel equation and extracted a decoherence time in gold of 4 ps. We also investigated the LDOS of small ridges of Au deposited on the top of the Nb lines. In this case, L ≤ ξ N and the spatial variations of the spectra depend on the exact shape of the Au ridge. However, our results are consistent with a predicted minigap related to the Thouless energy. (4. mesoscopic superconductivity)

  12. A current controlled variable delay superconducting transmission line

    Anlage, S.M.; Snortland, H.J.; Beasley, M.R.

    1989-01-01

    The authors present a device concept for a current-controlled variable delay for superconducting transmission line. The device makes use of the change in kinetic inductance of a superconducting transmission line under the application of a DC bias current. The relevant materials parameters and several promising superconducting materials have been identified

  13. Field Applications of Gamma Column Scanning Technology

    Aquino, Denis D.; Mallilin, Janice P.; Nuñez, Ivy Angelica A.; Bulos, Adelina DM.

    2015-01-01

    The Isotope Techniques Section (ITS) under the Nuclear Service Division (NSD) of the Philippine Nuclear Research Institute (PNRI) conducts services, research and development on radioisotope and sealed source application in the industry. This aims to benefit the manufacturing industries such as petroleum, petrochemical, chemical, energy, waste, column treatment plant, etc. through on line inspection and troubleshooting of a process vessel, column or pipe that could optimize the process operation and increase production efficiency. One of the most common sealed source techniques for industrial applications is the gamma column scanning technology. Gamma column scanning technology is an established technique for inspection, analysis and diagnosis of industrial columns for process optimization, solving operational malfunctions and management of resources. It is a convenient non-intrusive, cost effective and cost-efficient technique to examine inner details of an industrial process vessel such as a distillation column while it is in operation. The Philippine Nuclear Research Institute (PNRI) recognize the importance and benefits of this technology and has implemented activities to make gamma column scanning locally available to benefit the Philippine industries. Continuous effort for capacity building is being pursued thru the implementation of in-house and on-the-job training abroad and upgrading of equipment. (author)

  14. Practical microwave electron devices

    Meurant, Gerard

    2013-01-01

    Practical Microwave Electron Devices provides an understanding of microwave electron devices and their applications. All areas of microwave electron devices are covered. These include microwave solid-state devices, including popular microwave transistors and both passive and active diodes; quantum electron devices; thermionic devices (including relativistic thermionic devices); and ferrimagnetic electron devices. The design of each of these devices is discussed as well as their applications, including oscillation, amplification, switching, modulation, demodulation, and parametric interactions.

  15. Off-line coupling of new generation centrifugal partition chromatography device with preparative high pressure liquid chromatography-mass spectrometry triggering fraction collection applied to the recovery of secoiridoid glycosides from Centaurium erythraea Rafn. (Gentianaceae).

    Mandova, Tsvetelina; Audo, Grégoire; Michel, Sylvie; Grougnet, Raphaël

    2017-09-01

    A purification sequence including a Gilson CPC 250 PRO device coupled to PrepHPLC hyphenated with a MS triggering fraction collector was applied to isolate secoiridoid glycosides from a complex methanolic extract of Centaurium erythraea. This species is widely used for ethnomedicinal purposes around the Mediterranean Sea. The solvent system ethyle acetate/ethanol/water 7.5/3/5 was determined using shake-flask method targeting swertiamarin, the major secoiridoid of the extract. Optimization of CPC experimental parameters enabled the injection of 4g of extract with a flow rate of 40mL/min at 3000rpm to provide a secoiridoid glycosides enriched fraction. 130mg of this latter was submitted to a second step of purification by preparative HPLC (gradient water/formic acid (19:1) (A) and methanol (B) as follows: 0min, 85% A; 8min, 60% A; 12min, 55% A; 35min, 55% A; 40min, 10% A; 50min, 10% A; 52min, 85% A; 55min, 85% A) to give swertiamarin (36mg, yield 27.7%, purity 98.2%). Other secoiridoid glycosides (sweroside, gentiopicroside, secologanol, secoxyloganin) were also isolated in minor amounts. As these monoterpene derivatives are responsible for several biological activities, their quick recovery with high yield and purity may serve as a model for further scale-up and industrial development. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Accuracy assessment of airborne laser scanning strips using planar features

    Soudarissanane, S.S.; Van der Sande, C.J.; Khoshelham, K.

    2010-01-01

    Airborne Laser Scanning (ALS) is widely used in many applications for its high measurement accuracy, fast acquisition capability, and large spatial coverage. Accuracy assessment of the ALS data usually relies on comparing corresponding tie elements, often points or lines, in the overlapping strips.

  17. Thermonuclear device

    Furuyama, Masayuki.

    1979-01-01

    Purpose: To provide the subject device wherein a conductive short-circuiting ring is installed in the vicinity of the bonded part of bellows and thick portion of vacuum vessel in the small circumferential direction of torus, thereby to reduce the electromagnetic force generated at the bellows. Constitution: A conductive short-circuiting ring is provided in the vicinity of the connected part of a thick portion and bellows portion. By this organization, a saddle type current generated at the thick portion by a vertical magnetic field flows through the short-circuiting ring because the resistance at a part where the short-circuiting ring is provided is reduced, and the current flowing through the bellows is remarkably reduced. For this reason, the electromagnetic force generated at the bellows is reduced thereby to prevent the bellows from being destroyed by the electromagnetic force. (Yoshihara, H.)

  18. Electrophoresis device

    Rhodes, P. H.; Snyder, R. S. (Inventor)

    1982-01-01

    A device for separating cellular particles of a sample substance into fractionated streams of different cellular species includes a casing having a distribution chamber, a separation chamber, and a collection chamber. The electrode chambers are separated from the separation chamber interior by means of passages such that flow variations and membrane variations around the slotted portion of the electrode chamber do not enduce flow perturbations into the laminar buffer curtain flowing in the separation chamber. The cellular particles of the sample are separated under the influence of the electrical field and the separation chamber into streams of different cellular species. The streams of separated cells enter a partition array in the collection chamber where they are fractionated and collected.

  19. Thermonuclear device

    Suzuki, Shohei

    1988-01-01

    Purpose: To obtain high voltage withstanding current introduction terminals not suffering from the effects of the reduction in the creeping voltage withstanding property by the application of magnetic fields. Constitution: This invention concerns a current introduction terminal for supplying electric current to coils for use in a thermonuclear device, etc. The conductor of the current introduction terminal on the side of vacuum is completely covered with solid insulator. This can eliminate the portion of securing the creeping withstanding voltage. The voltage withstanding characteristics of the solid insulator covering the portion of the conductor on the side of vacuum has a constant value irrespective of the atmosphere or the absence or presence of magnetic fields. Accordingly, the voltage withstanding characteristics of the current introduction terminal on the side of vacuum are determined by the property of the solid insulator, which is not reduced by the application of magnetic fields. (Ikeda, J.)

  20. An interchangeable scanning Hall probe/scanning SQUID microscope

    Tang, Chiu-Chun; Lin, Hui-Ting; Wu, Sing-Lin; Chen, Tse-Jun; Wang, M. J.; Ling, D. C.; Chi, C. C.; Chen, Jeng-Chung

    2014-01-01

    We have constructed a scanning probe microscope for magnetic imaging, which can function as a scanning Hall probe microscope (SHPM) and as a scanning SQUID microscope (SSM). The scanning scheme, applicable to SHPM and SSM, consists of a mechanical positioning (sub) micron-XY stage and a flexible direct contact to the sample without a feedback control system for the Z-axis. With the interchangeable capability of operating two distinct scanning modes, our microscope can incorporate the advantageous functionalities of the SHPM and SSM with large scan range up to millimeter, high spatial resolution (⩽4 μm), and high field sensitivity in a wide range of temperature (4.2 K-300 K) and magnetic field (10 −7 T-1 T). To demonstrate the capabilities of the system, we present magnetic images scanned with SHPM and SSM, including a RbFeB magnet and a nickel grid pattern at room temperature, surface magnetic domain structures of a La 2/3 Ca 1/3 MnO 3 thin film at 77 K, and superconducting vortices in a striped niobium film at 4.2 K